WorldWideScience

Sample records for digital damper system

  1. Transverse digital damper system for the Fermilab anti-proton recycler

    International Nuclear Information System (INIS)

    Eddy, N.; Crisp, J.; Fermilab

    2006-01-01

    A transverse damping system is used in the Recycler at Fermilab to damp beam instabilities which arise from large beam intensities with electron cooling. Initial tests of electron cooling demonstrated beam loss due to transverse beam motion when the beam was cooled past the beam density threshold. The transverse damper system consists of two horizontal and two vertical pickups whose signals are amplified and passed into an analog hybrid to generate a difference signal from each pickup. The difference signals are input to a custom digital damper board which digitizes the analog signals at 212mhz, performs digital processing of the signals inside a large Altera Stratix II FPGA, then provides analog output at 212mhz via digital to analog converters. The digital damper output is sent to amplifiers which drive one horizontal and one vertical kicker. An initial prototype digital damper board has been successfully used in the Recycler for over six months. Currently, work is underway to replace the prototype board with an upgraded VME version

  2. Digital transverse beam dampers from the Brookhaven AGS

    International Nuclear Information System (INIS)

    Smith, G.A.; Castillo, V.; Roser, T.; Van Asselt, W.; Witkover, R.; Wong, V.

    1995-01-01

    A wide band, digital damper system has been developed and is in use at the Brookhaven Alternating Gradient Synchrotron (AGS). The system consists of vertical and horizontal capacitive pickups, analog and digital processing electronics, four 500 Watt wide band power amplifiers, and two pairs of strip line beam kickers. The system is currently used to damp transverse coherent instabilities and injection errors, in both planes, for protons and all species of heavy ions. This paper discusses the system design and operation, particularly with regard to stabilization of the high intensity proton beam. The analog and digital signal processing techniques used to achieve optimum results are discussed. Operational data showing the effect of the damping are presented

  3. Beam stability in synchrotrons with digital filters in the feedback loop of a transverse damper

    International Nuclear Information System (INIS)

    Zhabitskij, V.M.

    2009-01-01

    The stability of an ion beam in synchrotrons with digital filters in the feedback loop of a transverse damper is treated. Solving the characteristic equation allows one to calculate the achievable damping rates as a function of instability growth rate, feedback gain and parameters of the signal processing. A transverse feedback system (TFS) is required in synchrotrons to stabilize the high intensity ion beams against transverse instabilities and to damp the beam injection errors. The TFS damper kicker (DK) corrects the transverse momentum of a bunch in proportion to its displacement from the closed orbit at the location of the beam position monitor (BPM). The digital signal processing unit in the feedback loop between BPM and DK ensures a condition to achieve optimal damping. Damping rates of the feedback systems with digital notch, Hilbert and all-pass filters are analyzed in comparison with those in an ideal feedback system

  4. Operational performance of a bunch by bunch digital damper in the Fermilab Main Injector

    International Nuclear Information System (INIS)

    Adamson, P.; Ashmanskas, W.J.; Foster, G.W.; Hansen, S.; Marchionni, A.; Nicklaus, D.; Semenov, A.; Wildman, D.; Kang, H.

    2005-01-01

    We have implemented a transverse and longitudinal bunch by bunch digital damper system in the Fermilab Main Injector, using a single digital board for all 3 coordinates. The system has been commissioned over the last year, and is now operational in all MI cycles, damping beam bunched at both 53MHz and 2.5MHz. We describe the performance of this system both for collider operations and high-intensity running for the NuMI project

  5. Digital active material processing platform effort (DAMPER), SBIR phase 2

    Science.gov (United States)

    Blackburn, John; Smith, Dennis

    1992-11-01

    Applied Technology Associates, Inc., (ATA) has demonstrated that inertial actuation can be employed effectively in digital, active vibration isolation systems. Inertial actuation involves the use of momentum exchange to produce corrective forces which act directly on the payload being actively isolated. In a typical active vibration isolation system, accelerometers are used to measure the inertial motion of the payload. The signals from the accelerometers are then used to calculate the corrective forces required to counteract, or 'cancel out' the payload motion. Active vibration isolation is common technology, but the use of inertial actuation in such systems is novel, and is the focus of the DAMPER project. A May 1991 report was completed which documented the successful demonstration of inertial actuation, employed in the control of vibration in a single axis. In the 1 degree-of-freedom (1DOF) experiment a set of air bearing rails was used to suspend the payload, simulating a microgravity environment in a single horizontal axis. Digital Signal Processor (DSP) technology was used to calculate in real time, the control law between the accelerometer signals and the inertial actuators. The data obtained from this experiment verified that as much as 20 dB of rejection could be realized by this type of system. A discussion is included of recent tests performed in which vibrations were actively controlled in three axes simultaneously. In the three degree-of-freedom (3DOF) system, the air bearings were designed in such a way that the payload is free to rotate about the azimuth axis, as well as translate in the two horizontal directions. The actuator developed for the DAMPER project has applications beyond payload isolation, including structural damping and source vibration isolation. This report includes a brief discussion of these applications, as well as a commercialization plan for the actuator.

  6. The transverse damper system for RHIC

    International Nuclear Information System (INIS)

    Xu, J.; Claus, J.; Raka, E.; Ruggiero, A.G.; Shea, T.J.

    1991-01-01

    If the beam is injected with errors x c , x' c (or y c , y' c ) with respect to the closed orbit or disturbed by transverse instabilities, it will execute coherent oscillations and will be diluted in betatron phase space within a time interval of about 1/Δν turns, even if it is properly matched to the focusing characteristics of the lattice, unless there is an effective damper system to prevent this. Here Δν is the tune spread in the beam. Such a damper will not prevent dilution due to mismatches. Without such a damper the emittance of the beam will ultimately develop to a properly centered matched ellipse with an area ε in phase space that is larger than that of the injected one ε 0 which is also matched but off-centered by x c and x' c

  7. Reduction of magneto rheological dampers stiffness by incorporating of an eddy current damper

    Science.gov (United States)

    Asghar Maddah, Ali; Hojjat, Yousef; Reza Karafi, Mohammad; Reza Ashory, Mohammad

    2017-05-01

    In this paper, a hybrid damper is developed to achieve lower stiffness compared to magneto rheological dampers. The hybrid damper consists of an eddy current damper (ECD) and a Magneto Rheological Damper (MRD). The aim of this research is to reduce the stiffness of MRDs with equal damping forces. This work is done by adding an eddy current passive damper to a semi-active MRD. The ECDs are contactless dampers which show an almost viscous damping behavior without increasing the stiffness of a system. However, MRDs increase damping and stiffness of a system simultaneously, when a magnetic field is applied. Damping of each part is studied theoretically and experimentally. A semi-empirical model is developed to explain the viscoelastic behavior of the damper. The experimental results showed that the hybrid damper is able to dissipate energy as much as those of MRDs while its stiffness is 12% lower at a zero excitation current.

  8. Analysis of Train Suspension System Using MR dampers

    Science.gov (United States)

    RamaSastry, DVA; Ramana, K. V.; Mohan Rao, N.; Siva Kumar, SVR; Priyanka, T. G. L.

    2016-09-01

    This paper deals with introducing MR dampers to the Train Suspension System for improving the ride comfort of the passengers. This type of suspension system comes under Semi-active suspension system which utilizes the properties of MR fluid to damp the vibrations. In case of high speed trains, the coach body is subjected to vibrations due to vertical displacement, yaw and pitch movements. When the body receives these disturbances from the ground,the transmission of vibrations to the passenger increases which affect the ride comfort. In this work, the equations of motion of suspension system are developed for both conventional passive system and semi-active system and are modelled in Matlab/Simulink and analysis has been carried out. The passive suspension system analysis shows that it is taking more time to damp the vibrations and at the same time the transmissibility of vibrations is more.Introducing MR dampers,vertical and angular displacements of the body are computed and compared. The results show that the introduction of MR dampers into the train suspension system improves ride comfort.

  9. Formulation and solutions of fractional continuously variable order mass–spring–damper systems controlled by viscoelastic and viscous–viscoelastic dampers

    Directory of Open Access Journals (Sweden)

    S Saha Ray

    2016-05-01

    Full Text Available This article presents the formulation and a new approach to find analytic solutions for fractional continuously variable order dynamic models, namely, fractional continuously variable order mass–spring–damper systems. Here, we use the viscoelastic and viscous–viscoelastic dampers for describing the damping nature of the oscillating systems, where the order of fractional derivative varies continuously. Here, we handle the continuous changing nature of fractional order derivative for dynamic systems, which has not been studied yet. By successive recursive method, here we find the solution of fractional continuously variable order mass–spring–damper systems and then obtain closed-form solutions. We then present and discuss the solutions obtained in the cases with continuously variable order of damping for oscillator through graphical plots.

  10. MEMS mass-spring-damper systems using an out-of-plane suspension scheme

    KAUST Repository

    Abdel Aziz, Ahmed Kamal Said; Sharaf, Abdel Hameed; Serry, Mohamed Yousef; Sedky, Sherif Salah

    2014-01-01

    MEMS mass-spring-damper systems (including MEMS gyroscopes and accelerometers) using an out-of-plane (or vertical) suspension scheme, wherein the suspensions are normal to the proof mass, are disclosed. Such out-of-plane suspension scheme helps such MEMS mass-spring-damper systems achieve inertial grade performance. Methods of fabricating out-of-plane suspensions in MEMS mass-spring-damper systems (including MEMS gyroscopes and accelerometers) are also disclosed.

  11. MEMS mass-spring-damper systems using an out-of-plane suspension scheme

    KAUST Repository

    Abdel Aziz, Ahmed Kamal Said

    2014-02-04

    MEMS mass-spring-damper systems (including MEMS gyroscopes and accelerometers) using an out-of-plane (or vertical) suspension scheme, wherein the suspensions are normal to the proof mass, are disclosed. Such out-of-plane suspension scheme helps such MEMS mass-spring-damper systems achieve inertial grade performance. Methods of fabricating out-of-plane suspensions in MEMS mass-spring-damper systems (including MEMS gyroscopes and accelerometers) are also disclosed.

  12. A gun recoil system employing a magnetorheological fluid damper

    International Nuclear Information System (INIS)

    Li, Z C; Wang, J

    2012-01-01

    This research aims to design and control a full scale gun recoil buffering system which works under real firing impact loading conditions. A conventional gun recoil absorber is replaced with a controllable magnetorheological (MR) fluid damper. Through dynamic analysis of the gun recoil system, a theoretical model for optimal design and control of the MR fluid damper for impact loadings is derived. The optimal displacement, velocity and optimal design rules are obtained. By applying the optimal design theory to protect against impact loadings, an MR fluid damper for a full scale gun recoil system is designed and manufactured. An experimental study is carried out on a firing test rig which consists of a 30 mm caliber, multi-action automatic gun with an MR damper mounted to the fixed base through a sliding guide. Experimental buffering results under passive control and optimal control are obtained. By comparison, optimal control is better than passive control, because it produces smaller variation in the recoil force while achieving less displacement of the recoil body. The optimal control strategy presented in this paper is open-loop with no feedback system needed. This means that the control process is sensor-free. This is a great benefit for a buffering system under impact loading, especially for a gun recoil system which usually works in a harsh environment. (paper)

  13. Evaluation of applicability of lead damper to 3-dimensional isolation system based on loading tests

    International Nuclear Information System (INIS)

    Matsuda, Akihiro

    2003-01-01

    To develop a damper for 3-dimensional base isolation system, horizontal and vertical mechanical properties, effect of loading frequency on vertical mechanical properties, coupled properties between horizontal and vertical directions, stability performance due to cyclic deformation are evaluated experimentally using scale models of lead damper originally developed for horizontal base isolation system. Loading test results are summarized as follows; 1) The lead damper has good vertical damping performance, in that the vertical yield load of the lead damper is three times as large as that for the horizontal direction, and the lead damper shows plastic behavior in the small deformation region. 2) The lead damper shows enough stability for static vertical displacement of ±40 mm. 3) the lead damper shows high stability performance for dynamic cyclic loading test using motions of isolation layer calculated by earthquake response analysis of FBR building subjected to S2-earthquake motion. Thus, applicability of the lead damper to 3-dimensional isolation system is shown from these results. (author)

  14. Theoretical and experimental study on dynamic responses of piping systems with combined dampers

    International Nuclear Information System (INIS)

    Gershtein, M.; Fridman, Ya.; Perelmiter, A.

    1996-01-01

    Vibrations of pipelines transporting fluids, gases, and granular materials are excited by the air flow, internal pressure pulsation, or seismic ground motion. The susceptibility of oil and gas pipelines to seismic damage has been demonstrated in earthquakes everywhere around the world. Devices for above-ground pipelines and piping systems vibration suppression with combination of dry friction and viscous energy dissipation are developed by AVIBRA, Shear deformation of viscous-elastic material in these devices occurs prior to interfacial slip. The way to account this phenomenon is to model the damper as an elastic-viscous element in series with an ideal Coulomb dry friction element. The harmonic balance method was applied to obtain an equivalent viscous damping constant for a combined damper. Iteration process was used to predict a dynamic response of a piping system with combined dampers subjected to sinusoidal excitation. Every iteration step was based on ANSYS procedures. Time integration of systems with hysteretic friction models presents computational difficulties. Some examples of dynamic responses of piping systems were analyzed by a time integration procedure for finite-element models. Combined dry friction-viscous dissipation dampers were tested on a piping model under harmonic excitation. It was clarified that combined dampers are very effective to reduce dynamic response. The seismic response of the piping system with combined dampers was calculated using time history finite-element analysis. The excellent effectiveness of AVIBRA combined dampers for aseismic design and retrofitting of pipelines and piping systems was confirmed by the analysis

  15. Results from the AGS Booster transverse damper

    International Nuclear Information System (INIS)

    Russo, D.; Brennan, M.; Meth, M.; Roser, T.

    1993-01-01

    To reach the design intensity of 1.5 x 10 13 protons per pulse in the AGS Booster, transverse coupled bunch instabilities with an estimated growth rate of 1500s -1 have to be dampened. A prototype transverse damper has been tested successfully using a one turn digital delay and closed orbit suppression implemented in a programmable gate array. An updated damper, which includes an algorithm to optimize damping for a changing betatron rune, will also be presented

  16. Digital Signal Processing Applications and Implementation for Accelerators Digital Notch Filter with Programmable Delay and Betatron Phase Adjustment for the PS, SPS and LHC Transverse Dampers

    CERN Document Server

    Rossi, V

    2002-01-01

    In the framework of the LHC project and the modifications of the SPS as its injector, I present the concept of global digital signal processing applied to a particle accelerator, using Field Programmable Gate Array (FPGA) technology. The approach of global digital synthesis implements in numerical form the architecture of a system, from the start up of a project and the very beginning of the signal flow. It takes into account both the known parameters and the future evolution, whenever possible. Due to the increased performance requirements of today's projects, the CAE design methodology becomes more and more necessary to handle successfully the added complexity and speed of modern electronic circuits. Simulation is performed both for behavioural analysis, to ensure conformity to functional requirements, and for time signal analysis (speed requirements). The digital notch filter with programmable delay for the SPS Transverse Damper is now fully operational with fixed target and LHC-type beams circulating in t...

  17. LOW FREQUENCY DAMPER

    Directory of Open Access Journals (Sweden)

    Radu BOGATEANU

    2009-09-01

    Full Text Available The low frequency damper is an autonomous equipment for damping vibrations with the 1-20Hz range.Its autonomy enables the equipment to be located in various mechanical systems, without requiring special hydraulic installations.The low frequency damper was designed for damping the low frequency oscillations occurring in the circuit controls of the upgraded IAR-99 Aircraft.The low frequency damper is a novelty in the aerospace field ,with applicability in several areas as it can be built up in an appropriate range of dimensions meeting the requirements of different beneficiaries. On this line an equipment able to damp an extended frequency range was performed for damping oscillations in the pipes of the nuclear power plants.This damper, tested in INCAS laboratories matched the requirements of the beneficiary.The low frequency damper is patented – the patent no. 114583C1/2000 is held by INCAS.

  18. Site selection of active damper for stabilizing power electronics based power distribution system

    DEFF Research Database (Denmark)

    Yoon, Changwoo; Wang, Xiongfei; Bak, Claus Leth

    2015-01-01

    electronics based power device, which provides an adjustable damping capability to the power system where the voltage harmonic instability is measured. It can stabilize by adjusting the equivalent node impedance with its plug and play feature. This feature gives many degrees of freedom of its installation......Stability in the nowadays distribution power system is endangered by interaction problems that may arise from newly added power-electronics based power devices. Recently, a new concept to deal with this higher frequency instability, the active damper, has been proposed. The active damper is a power...... point when the system has many nodes. Therefore, this paper addresses the proper placement of an active damper in an unstable small-scale power distribution system. A time-domain model of the Cigre benchmark low-vltage network is used as a test field. The result shows the active damper location...

  19. Controllable outrigger damping system for high rise building with MR dampers

    Science.gov (United States)

    Wang, Zhihao; Chang, Chia-Ming; Spencer, Billie F., Jr.; Chen, Zhengqing

    2010-04-01

    A novel energy dissipation system that can achieve the amplified damping ratio for a frame-core tube structures is explored, where vertical dampers are equipped between the outrigger and perimeter columns. The modal characteristics of the structural system with linear viscous dampers are theoretically analyzed from the simplified finite element model by parametric analysis. The result shows that modal damping ratios of the first several modes can increase a lot with this novel damping system. To improve the control performance of system, the semi-active control devices, magnetorheological (MR) dampers, are adopted to develop a controllable outrigger damping system. The clipped optimal control with the linear-quadratic Gaussian (LQG) acceleration feedback is adopted in this paper. The effectiveness of both passive and semi-active control outrigger damping systems is evaluated through the numerical simulation of a representative tall building subjected to two typical earthquake records.

  20. Multi-functional hinge equipped with a magneto-rheological rotary damper for solar array deployment system

    Science.gov (United States)

    Wen, Mingfu; Yu, Miao; Fu, Jie; Wu, Zhengzhong

    2015-02-01

    This article describes the design and simulation of a novel multi-functional hinge equipped with a rotary magnetorheological damper for solar array deployment system, which is comprised of a hinge, an angular sensor, a positioning and locking mechanism and a rotary damper. In order to achieve the compact design in structure, some components were reused in different function modules. It's the first to use magnet-rheological fluid (MRF) to dissipate the energy in solar array deployment system. The main advantage in using MR rotary damper instead of a viscous fluid rotary damper is that the damping force of MR damper can be adjusted according to the external magnetic field environment excited. A mechanic model was built and the structure design was focused on the MR rotary damper, a damping force model of this damper is deduced based on hydromechanics with Bingham plastic constitutive model. A simulation of deployment motion was taken to validate the motion sequence of various components during the unfolding and locking process. It can be obtained that a constant damping coefficient can hardly balance the different performance of solar deployment system, then a simulation of the proposed deployment system equipped with rotary MR damper was carried out. According to the simulation, it can be obtained that the terminal velocity decreased by 75.81% and the deployment time decreased by 72.37% compared with a given constant damping coefficients. Therefore, the proposed new type of rotary damper can reach a compromise with different performance utilizing an on-off control strategy.

  1. Response of air cleaning system dampers and blowers to simulated tornado transients

    International Nuclear Information System (INIS)

    Gregory, W.; Idar, E.; Smith, P.; Hensel, E.; Smith, E.

    1985-01-01

    The effects of tornado-like pressure transients upon dampers and blowers in nuclear air cleaning systems were studied. For the dampers pressure drop as a function of flow rate was obtained and an empirical relationship developed. Transient response was examined for several types of dampers, as was structural integrity. Both centrifugal and axi-vane blowers were tested and transient characteristic curves were generated in outrunning and backflow situations. The transient characteristic curves do not necessarily match the quasi-steady characteristic curves

  2. Experimental investigation of the seismic control of a nonlinear soil-structure system using MR dampers

    International Nuclear Information System (INIS)

    Li, Hui; Wang, Jian

    2011-01-01

    This paper reports the results of an experimental study conducted to demonstrate the feasibility and capability of magnetorheological (MR) dampers commanded by a decentralized control algorithm for seismic control of nonlinear civil structures considering soil-structure interaction (SSI). A two-story reinforced concrete (RC) frame resting in a laminar soil container is employed as the test specimen, and two MR dampers equipped in the first story are used to mitigate the response of this frame subjected to various intensity seismic excitations. A hyperbolic tangent function is used to represent the hysteretic behavior of the MR damper and a decentralized control approach for commanding MR dampers is proposed and implemented in the shaking table tests. Only the response of the first story is feedback for control command calculation of the MR dampers. The results indicate that the MR damper can effectively reduce the response of the soil-structure system, even when the soil-structure system presents complex nonlinear hysteretic behavior. The robustness of the proposed decentralized control algorithm is validated through the shaking table tests on the soil-structure system with large uncertainty. The most interesting findings in this paper are that MR dampers not only mitigate the superstructure response, but also reduce the soil response, pile response and earth pressure on the pile foundation

  3. Performance Evaluation on Transmission Tower-Line System with Passive Friction Dampers Subjected to Wind Excitations

    Directory of Open Access Journals (Sweden)

    Bo Chen

    2015-01-01

    Full Text Available The vibration control and performance evaluation on a transmission-tower line system by using friction dampers subjected to wind excitations are carried out in this study. The three-dimensional finite element (FE model of a transmission tower is firstly constructed. A two-dimensional lumped mass model of a transmission tower is developed for dynamic analysis. The analytical model of transmission tower-line system is proposed by taking the dynamic interaction between the tower and the transmission lines into consideration. The mechanical model of passive friction damper is presented by involving the effects of damper axial stiffness. The equation of motion of the transmission tower-line system incorporated with the friction dampers disturbed by wind excitations is established. A real transmission tower-line system is taken as an example to examine the feasibility and reliability of the proposed control approach. An extensive parameter study is carried out to find the optimal parameters of friction damper and to assess the effects of slipping force axial stiffness and hysteresis loop on control performance. The work on an example structure indicates that the application of friction dampers with optimal parameters could significantly reduce wind-induced responses of the transmission tower-line system.

  4. Adaptive tuning of elasto-plastic damper

    DEFF Research Database (Denmark)

    Høgsberg, Jan Riess; Krenk, Steen

    2007-01-01

    the damper parameter(s) with respect to the magnitude of the damper motion. The procedure is demonstrated in terms of the bilinear elasto-plastic damper model, and optimality corresponds to maximum modal damping. A parametric solution for the damping ratio is obtained by a two-component system reduction...

  5. A semi-active control suspension system for railway vehicles with magnetorheological fluid dampers

    Science.gov (United States)

    Wei, Xiukun; Zhu, Ming; Jia, Limin

    2016-07-01

    The high-speed train has achieved great progress in the last decades. It is one of the most important modes of transportation between cities. With the rapid development of the high-speed train, its safety issue is paid much more attention than ever before. To improve the stability of the vehicle with high speed, extra dampers (i.e. anti-hunting damper) are used in the traditional bogies with passive suspension system. However, the curving performance of the vehicle is undermined due to the extra lateral force generated by the dampers. The active suspension systems proposed in the last decades attempt to solve the vehicle steering issue. However, the active suspension systems need extra actuators driven by electrical power or hydraulic power. There are some implementation and even safety issues which are not easy to be overcome. In this paper, an innovative semi-active controlled lateral suspension system for railway vehicles is proposed. Four magnetorheological fluid dampers are fixed to the primary suspension system of each bogie. They are controlled by online controllers for enhancing the running stability on the straight track line on the one hand and further improving the curving performance by controlling the damper force on the other hand. Two control strategies are proposed in the light of the pure rolling concept. The effectiveness of the proposed strategies is demonstrated by SIMPACK and Matlab co-simulation for a full railway vehicle with two conventional bogies.

  6. Assessment of semi-active friction dampers

    Science.gov (United States)

    dos Santos, Marcelo Braga; Coelho, Humberto Tronconi; Lepore Neto, Francisco Paulo; Mafhoud, Jarir

    2017-09-01

    The use of friction dampers has been widely proposed for a variety of mechanical systems for which applying viscoelastic materials, fluid based dampers or other viscous dampers is impossible. An important example is the application of friction dampers in aircraft engines to reduce the blades' vibration amplitudes. In most cases, friction dampers have been studied in a passive manner, but significant improvements can be achieved by controlling the normal force in the contact region. The aim of this paper is to present and study five control strategies for friction dampers based on three different hysteresis cycles by using the Harmonic Balance Method (HBM), a numerical and experimental analysis. The first control strategy uses the friction force as a resistance when the system is deviating from its equilibrium position. The second control strategy maximizes the energy removal in each harmonic oscillation cycle by calculating the optimal normal force based on the last displacement peak. The third control strategy combines the first strategy with the homogenous modulation of the friction force. Finally, the last two strategies attempt to predict the system's movement based on its velocity and acceleration and our knowledge of its physical properties. Numerical and experimental studies are performed with these five strategies, which define the performance metrics. The experimental testing rig is fully identified and its parameters are used for numerical simulations. The obtained results show the satisfactory performance of the friction damper and selected strategy and the suitable agreement between the numerical and experimental results.

  7. Free vibration analysis of linear particle chain impact damper

    Science.gov (United States)

    Gharib, Mohamed; Ghani, Saud

    2013-11-01

    Impact dampers have gained much research interest over the past decades that resulted in several analytical and experimental studies being conducted in that area. The main emphasis of such research was on developing and enhancing these popular passive control devices with an objective of decreasing the three parameters of contact forces, accelerations, and noise levels. To that end, the authors of this paper have developed a novel impact damper, called the Linear Particle Chain (LPC) impact damper, which mainly consists of a linear chain of spherical balls of varying sizes. The LPC impact damper was designed utilizing the kinetic energy of the primary system through placing, in the chain arrangement, a small-sized ball between each two large-sized balls. The concept of the LPC impact damper revolves around causing the small-sized ball to collide multiple times with the larger ones upon exciting the primary system. This action is believed to lead to the dissipation of part of the kinetic energy at each collision with the large balls. This paper focuses on the outcome of studying the free vibration of a single degree freedom system that is equipped with the LPC impact damper. The proposed LPC impact damper is validated by means of comparing the responses of a single unit conventional impact damper with those resulting from the LPC impact damper. The results indicated that the latter is considerably more efficient than the former impact damper. In order to further investigate the LPC impact damper effective number of balls and efficient geometry when used in a specific available space in the primary system, a parametric study was conducted and its result is also explained herein. Single unit impact damper [14-16]. Multiunit impact damper [17,18]. Bean bag impact damper [19,20]. Particle/granular impact damper [21,23,22]. Resilient impact damper [24]. Buffered impact damper [25-27]. Multiunit impact damper consists of multiple masses instead of a single mass. This

  8. Study on coupled shock absorber system using four electromagnetic dampers

    International Nuclear Information System (INIS)

    Fukumori, Y; Hayashi, R; Okano, H; Suda, Y; Nakano, K

    2016-01-01

    Recently, the electromagnetic damper, which is composed of an electric motor, a ball screw, and a nut, was proposed. The electromagnetic damper has high responsiveness, controllability, and energy saving performance. It has been reported that it improved ride comfort and drivability. In addition, the authors have proposed a coupling method of two electromagnetic dampers. The method enables the characteristics of bouncing and rolling or pitching motion of a vehicle to be tuned independently. In this study, the authors increase the number of coupling of electromagnetic dampers from two to four, and propose a method to couple four electromagnetic dampers. The proposed method enables the characteristics of bouncing, rolling and pitching motion of a vehicle to be tuned independently. Basic experiments using proposed circuit and motors and numerical simulations of an automobile equipped with the proposed coupling electromagnetic damper are carried out. The results indicate the proposed method is effective. (paper)

  9. Performance analysis of supply and return fans for HVAC systems under different operating strategies of economizer dampers

    Energy Technology Data Exchange (ETDEWEB)

    Nassif, Nabil [Florida Solar Energy Center, A Research Institute of the University of Center Florida, 1679 Clearlake Road, Cocoa, FL 32922 (United States)

    2010-07-15

    HVAC systems and associated equipment consume a relatively large fraction of total building energy consumption, a significant portion of which is attributed to fan operation. The operation of economizer dampers when installed can cause high energy consumption in fans if they are not functioning in proper and optimal manner. This will mainly be due to the potential high pressure drops through those dampers and associated high total pressures that should be developed by supply and/or return fans. It is then necessary to ensure that a proper strategy to operate optimally the economizer dampers is implemented with minimum fan energy use. The paper examines several operation strategies of the economizer dampers and investigates their effects on the performance of both the supply and return fans in HVAC system. It also discusses a new operating strategy for economizer dampers that can lead to lower fan energy use. The strategies are evaluated by simulations for a typically existing HVAC system. Several factors such as the building locations, system characteristics, resistance in the duct where the dampers are installed, supply air temperature and economizer control, and minimum ventilation requirements are also considered during the evaluations. The results show that the way of the economizer dampers been controlled has a significant effect on fan performance and its energy use. The proposed strategy if properly implemented can provide fan energy saving in the range of 5-30%, depending mainly on the number of hours when the system operates in the free cooling mode, damper characteristics, and minimum outdoor air. (author)

  10. Magnetorheological Damper Working in Squeeze Mode

    Directory of Open Access Journals (Sweden)

    Xinglong Gong

    2014-05-01

    Full Text Available This research is focused on evaluation of the magnetorheological fluids (MRFs based damper which works in squeeze mode. The operation direction of this damper is parallel to the direction of the external magnetic field. Before testing, commercial software ANSYS was used to analyze the magnetic field distribution inside the damper generated by charging current in the coil. The performance of the damper was tested by using the MTS809 (produced by MTS Systems Corporation, USA. For simulation of this damper, a mathematical model was set up. Experimental results showed that the small squeezed MR damper could produce large damping force; for example, the maximum damping force is nearly 6 kN, while the amplitude is 1.2 mm, the frequency is 1.0 Hz, and the current is 2.0 A, and the damping force was controllable by changing the current in the coil. The damping force versus displacement curves are complex. We divide them into four regions for simulation. The maximum damper force increased quickly with the increasing of the current in coil. This kind of damper can be used in vibration isolation for precise equipment.

  11. A new energy-harvesting device system for wireless sensors, adaptable to on-site monitoring of MR damper motion

    International Nuclear Information System (INIS)

    Yu, Miao; Peng, Youxiang; Wang, Siqi; Fu, Jie; Choi, S B

    2014-01-01

    Under extreme service conditions in vehicle suspension systems, some defects exist in the hardening, bodying, and poor temperature stability of magnetorheological (MR) fluid. These defects can cause weak and even invalid performance in the MR fluid damper (MR damper for short). To ensure the effective validity of the practical applicability of the MR damper, one must implement an online state-monitoring sensor to monitor several performance factors, such as acceleration. In this empirical work, we propose a new energy-harvesting device system for the wireless sensor system of an MR damper. The monitoring sensor system consists of several components, such as an energy-harvesting device, energy-management circuit, and wireless sensor node. The electrical energy harvested from the kinetic energy of the MR fluid that flows within the MR damper can be automatically charged and discharged with the help of an energy-management circuit for the wireless sensor node. After verifying good performance from each component, an experimental apparatus is built to evaluate the feasibility of the proposed self-powered wireless sensor system. The measured results of pressure, temperature, and acceleration data within the MR damper clearly demonstrate the practical applicability of monitoring the operating work states of the MR damper when it is subjected to sinusoidal excitation. (technical note)

  12. Hybrid viscous damper with filtered integral force feedback control

    DEFF Research Database (Denmark)

    Høgsberg, Jan; Brodersen, Mark L.

    2016-01-01

    In hybrid damper systems active control devices are usually introduced to enhance the performance of otherwise passive dampers. In the present paper a hybrid damper concept is comprised of a passive viscous damper placed in series with an active actuator and a force sensor. The actuator motion...... is controlled by a filtered integral force feedback strategy, where the main feature is the filter, which is designed to render a damper force that in a phase-plane representation operates in front of the corresponding damper velocity. It is demonstrated that in the specific parameter regime where the damper...

  13. First-principles simulation and comparison with beam tests for transverse instabilities and damper performance in the Fermilab Main Injector

    International Nuclear Information System (INIS)

    Nicklaus, Dennis; Foster, G.William; Kashikhin, Vladimir

    2005-01-01

    An end-to-end performance calculation and comparison with beam tests was performed for the bunch-by-bunch digital transverse damper in the Fermilab Main Injector. Time dependent magnetic wakefields responsible for ''Resistive Wall'' transverse instabilities in the Main Injector were calculated with OPERA-2D using the actual beam pipe and dipole magnet lamination geometry. The leading order dipole component was parameterized and used as input to a bunch-by-bunch simulation which included the filling pattern and injection errors experienced in high-intensity operation of the Main Injector. The instability growth times, and the spreading of the disturbance due to newly misinjected batches was compared between simulations and beam data collected by the damper system. Further simulation models the effects of the damper system on the beam

  14. A new controllable damper with neuro controller

    International Nuclear Information System (INIS)

    Kobayashi, N.; Kobayashi, H.; Saito, O.; Yokoi, R.; Morishita, S.

    1993-01-01

    A new controllable damper is proposed for suppressing the vibration of the piping system for wide frequency range. Electro-Rheological fluid (ER fluid) is enclosed in the damper casing in place of oil, and the apparent viscosity of ER fluid can be varied by applying electric field strength (E.F.S.), which is controlled by an adaptive neural network controller. The shaking test is conducted about a simplified L-shaped piping model with a prototype controllable damper. The test results show the effectiveness of the presented controllable damper for suppressing very small amplitude vibration of the piping system. Furthermore an application of neural network is discussed to control E.F.S. of the electrode. (author)

  15. Model predictive control of an air suspension system with damping multi-mode switching damper based on hybrid model

    Science.gov (United States)

    Sun, Xiaoqiang; Yuan, Chaochun; Cai, Yingfeng; Wang, Shaohua; Chen, Long

    2017-09-01

    This paper presents the hybrid modeling and the model predictive control of an air suspension system with damping multi-mode switching damper. Unlike traditional damper with continuously adjustable damping, in this study, a new damper with four discrete damping modes is applied to vehicle semi-active air suspension. The new damper can achieve different damping modes by just controlling the on-off statuses of two solenoid valves, which makes its damping adjustment more efficient and more reliable. However, since the damping mode switching induces different modes of operation, the air suspension system with the new damper poses challenging hybrid control problem. To model both the continuous/discrete dynamics and the switching between different damping modes, the framework of mixed logical dynamical (MLD) systems is used to establish the system hybrid model. Based on the resulting hybrid dynamical model, the system control problem is recast as a model predictive control (MPC) problem, which allows us to optimize the switching sequences of the damping modes by taking into account the suspension performance requirements. Numerical simulations results demonstrate the efficacy of the proposed control method finally.

  16. Control strategies for friction dampers: numerical assessment and experimental investigations.

    OpenAIRE

    Coelho H.T.; Santos M.B.; Lepore Neto F.P.; Mahfoud J.

    2014-01-01

    The use of friction dampers has been proposed in a wide variety of mechanical systems for which it is not possible to apply viscoelastic materials, fluid based dampers or others viscous dampers. An important example is the application of friction dampers in aircraft engines to reduce the blades vibration amplitudes. In most cases, friction dampers have been studied in a passive way, however, a significant improvement can be achieved by controlling the normal force in the dampers. The aim of t...

  17. Experimental Investigation on the Behavior of Bracing Damper Systems by Utilizing Metallic Yielding and Recentering Material Devices

    Directory of Open Access Journals (Sweden)

    Jong Wan Hu

    2018-01-01

    Full Text Available With the aim of effectively reducing the structural damage caused by earthquake events, bracing systems equipped with retrofitting damper devices, which take advantage of the energy dissipation and impact absorption, have been widely used in practical construction sites. These bracing dampers, however, have been recognized as expendable supplies for easily replacing the damaged ones after a strong earthquake because they are commonly designed to undergo concentrated force and deformation for the purpose of protecting the main structural members such as the columns and beams. In this paper, the use of new superelastic shape memory alloy (SMA dampers that can partially recover their original configuration is proposed to decrease the repair cost. In addition, the conventional steel dampers used for improving the energy dissipation arising due to metallic yielding are additionally integrated into the bracing member. The behaviors of such bracing systems with the damper devices were reproduced in experimental tests with the cyclic loading history, and then their strength capacity and recentering capability were estimated based on the experiment results. Finally, additional experimental tests were performed by imposing cyclic loading histories with different loading speeds on the superelastic SMA and steel plate damper specimens.

  18. Coulomb Friction Damper

    Science.gov (United States)

    Appleberry, W. T.

    1983-01-01

    Standard hydraulic shock absorber modified to form coulomb (linear friction) damper. Device damps very small velocities and is well suited for use with large masses mounted on soft springs. Damping force is easily adjusted for different loads. Dampers are more reliable than fluid dampers and also more economical to build and to maintain.

  19. Bifurcations and chaos of a vibration isolation system with magneto-rheological damper

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Hailong [Magneto-electronics Lab, School of Physics and Technology, Nanjing Normal University, Nanjing 210046 (China); Vibration Control Lab, School of Electrical and Automation Engineering, Nanjing Normal University, Nanjing 210042 (China); Zhang, Ning [Magneto-electronics Lab, School of Physics and Technology, Nanjing Normal University, Nanjing 210046 (China); Min, Fuhong; Yan, Wei; Wang, Enrong, E-mail: erwang@njnu.edu.cn [Vibration Control Lab, School of Electrical and Automation Engineering, Nanjing Normal University, Nanjing 210042 (China)

    2016-03-15

    Magneto-rheological (MR) damper possesses inherent hysteretic characteristics. We investigate the resulting nonlinear behaviors of a two degree-of-freedom (2-DoF) MR vibration isolation system under harmonic external excitation. A MR damper is identified by employing the modified Bouc-wen hysteresis model. By numerical simulation, we characterize the nonlinear dynamic evolution of period-doubling, saddle node bifurcating and inverse period-doubling using bifurcation diagrams of variations in frequency with a fixed amplitude of the harmonic excitation. The strength of chaos is determined by the Lyapunov exponent (LE) spectrum. Semi-physical experiment on the 2-DoF MR vibration isolation system is proposed. We trace the time history and phase trajectory under certain values of frequency of the harmonic excitation to verify the nonlinear dynamical evolution of period-doubling bifurcations to chaos. The largest LEs computed with the experimental data are also presented, confirming the chaotic motion in the experiment. We validate the chaotic motion caused by the hysteresis of the MR damper, and show the transitions between distinct regimes of stable motion and chaotic motion of the 2-DoF MR vibration isolation system for variations in frequency of external excitation.

  20. Bifurcations and chaos of a vibration isolation system with magneto-rheological damper

    Directory of Open Access Journals (Sweden)

    Hailong Zhang

    2016-03-01

    Full Text Available Magneto-rheological (MR damper possesses inherent hysteretic characteristics. We investigate the resulting nonlinear behaviors of a two degree-of-freedom (2-DoF MR vibration isolation system under harmonic external excitation. A MR damper is identified by employing the modified Bouc-wen hysteresis model. By numerical simulation, we characterize the nonlinear dynamic evolution of period-doubling, saddle node bifurcating and inverse period-doubling using bifurcation diagrams of variations in frequency with a fixed amplitude of the harmonic excitation. The strength of chaos is determined by the Lyapunov exponent (LE spectrum. Semi-physical experiment on the 2-DoF MR vibration isolation system is proposed. We trace the time history and phase trajectory under certain values of frequency of the harmonic excitation to verify the nonlinear dynamical evolution of period-doubling bifurcations to chaos. The largest LEs computed with the experimental data are also presented, confirming the chaotic motion in the experiment. We validate the chaotic motion caused by the hysteresis of the MR damper, and show the transitions between distinct regimes of stable motion and chaotic motion of the 2-DoF MR vibration isolation system for variations in frequency of external excitation.

  1. Gas Turbine Blade Damper Optimization Methodology

    Directory of Open Access Journals (Sweden)

    R. K. Giridhar

    2012-01-01

    Full Text Available The friction damping concept is widely used to reduce resonance stresses in gas turbines. A friction damper has been designed for high pressure turbine stage of a turbojet engine. The objective of this work is to find out effectiveness of the damper while minimizing resonant stresses for sixth and ninth engine order excitation of first flexure mode. This paper presents a methodology that combines three essential phases of friction damping optimization in turbo-machinery. The first phase is to develop an analytical model of blade damper system. The second phase is experimentation and model tuning necessary for response studies while the third phase is evaluating damper performance. The reduced model of blade is developed corresponding to the mode under investigation incorporating the friction damper then the simulations were carried out to arrive at an optimum design point of the damper. Bench tests were carried out in two phases. Phase-1 deals with characterization of the blade dynamically and the phase-2 deals with finding optimal normal load at which the blade resonating response is minimal for a given excitation. The test results are discussed, and are corroborated with simulated results, are in good agreement.

  2. A comparative analysis of the degree of stability and damper coefficient of an electric system

    Energy Technology Data Exchange (ETDEWEB)

    Gruzdev, I.A.; Shakhayeva, O.M.; Tin' , N.V.

    1981-01-01

    The problem is examined of optimization of parameters of strong action ARV. The technique is given for determining the damper coefficient from SG equations, and based on equivalent circuits. It is shown that use of the damper coefficient for estimating the length of transient processes is only possible for systems with low attenuation.

  3. a Method for Preview Vibration Control of Systems Having Forcing Inputs and Rapidly-Switched Dampers

    Science.gov (United States)

    ElBeheiry, E. M.

    1998-07-01

    In a variety of applications, especially in large scale dynamic systems, the mechanization of different vibration control elements in different locations would be decided by limitations placed on the modal vibration of the system and the inherent dynamic coupling between its modes. Also, the quality of vibration control to the economy of producing the whole system would be another trade-off leading to a mix of passive, active and semi-active vibration control elements in one system. This termactiveis limited to externally powered vibration control inputs and the termsemi-activeis limited to rapidly switched dampers. In this article, an optimal preview control method is developed for application to dynamic systems having active and semi-active vibration control elements mechanized at different locations in one system. The system is then a piecewise (bilinear) controller in which two independent sets of control inputs appear additively and multiplicatively. Calculus of variations along with the Hamiltonian approach are employed for the derivation of this method. In essence, it requires the active elements to be ideal force generators and the switched dampers to have the property of on-line variation of the damping characteristics to pre-determined limits. As the dampers switch during operation the whole system's structure differs, and then values of the active forcing inputs are adapted to match these rapid changes. Strictly speaking, each rapidly switched damper has pre-known upper and lower damping levels and it can take on any in-between value. This in-between value is to be determined by the method as long as the damper tracks a pre-known fully active control demand. In every damping state of each semi-active damper the method provides the optimal matching values of the active forcing inputs. The method is shown to have the feature of solving simple standard matrix equations to obtain closed form solutions. A comprehensive 9-DOF tractor semi-trailer model is used

  4. Performance of a viscous damper using electro-rheological fluid

    International Nuclear Information System (INIS)

    Otani, A.; Kobayashi, H.; Kobayashi, N.; Tadaishi, Y.

    1994-01-01

    A new damper has been developed that suppresses small-amplitude vibrations over a wide frequency range. The damper has been tested using both an electro-rheological fluid (ERF) and a highly viscous liquid, which are enclosed in the damper's casing (a metal bellows). The apparent viscosity of the ERF can be changed by varying the strength of the applied electrical field. Initially, a simple L-shaped piping model excited by a rotary-type exciter was used to investigate the performance of the damper, utilizing both fluids. The experimental results demonstrate the effectiveness of the passive damper. Based on the experimental results, application of the damper to an actual piping system with a big pump was carried out analytical

  5. DYNAMIC LOAD DAMPER MODELING

    Directory of Open Access Journals (Sweden)

    Loktev Aleksey Alekseevich

    2013-01-01

    Full Text Available The authors present their findings associated with their modeling of a dynamic load damper. According to the authors, the damper is to be installed onto a structure or its element that may be exposed to impact, vibration or any other dynamic loading. The damper is composed of paralleled or consecutively connected viscous and elastic elements. The authors study the influence of viscosity and elasticity parameters of the damper produced onto the regular displacement of points of the structure to be protected and onto the regular acceleration transmitted immediately from the damper to the elements positioned below it.

  6. A Cable-Passive Damper System for Sway and Skew Motion Control of a Crane Spreader

    Directory of Open Access Journals (Sweden)

    La Duc Viet

    2015-01-01

    Full Text Available While the crane control problem is often approached by applying a certain active control command to some parts of the crane, this paper proposes a cable-passive damper system to reduce the vibration of a four-cable suspended crane spreader. The residual sway and skew motions of a crane spreader always produce the angle deflections between the crane cables and the crane spreader. The idea in this paper is to convert those deflections into energy dissipated by the viscous dampers, which connect the cables and the spreader. The proposed damper system is effective in reducing spreader sway and skew motions. Moreover, the optimal damping coefficient can be found analytically by minimizing the time integral of system energy. The numerical simulations show that the proposed passive system can assist the input shaping control of the trolley motion in reducing both sway and skew responses.

  7. Innovative Seismic Response-Controlled System with Shear Wall and Concentrated Dampers in Lower Stories

    Directory of Open Access Journals (Sweden)

    Tsubasa Tani

    2017-10-01

    Full Text Available A new structural control system using damper-installed shear walls in lower stories with reduced stiffness is proposed for vibration control of high-rise RC buildings. That system has some design variables, i.e., height of shear wall, degree of stiffness reduction at lower stories, and quantity of dampers. In this paper, some parametric studies on the shear-beam model with a stiff beam against two kinds of ground motion, a pulse-type sinusoidal wave and a resonant sinusoidal wave, are conducted to clarify the vibration characteristics of the proposed structural control system. It is shown that the optimal combination of design parameters depends on the input ground motion. It is also shown that it is possible to prevent from increasing the response under the one-cycle sinusoidal input resonant to the lowest mode and reduce the steady-state response under the harmonic input with the resonant fundamental period by reducing the stiffness in the lower structure and increasing the damper deformation.

  8. A PSO Driven Intelligent Model Updating and Parameter Identification Scheme for Cable-Damper System

    Directory of Open Access Journals (Sweden)

    Danhui Dan

    2015-01-01

    Full Text Available The precise measurement of the cable force is very important for monitoring and evaluating the operation status of cable structures such as cable-stayed bridges. The cable system should be installed with lateral dampers to reduce the vibration, which affects the precise measurement of the cable force and other cable parameters. This paper suggests a cable model updating calculation scheme driven by the particle swarm optimization (PSO algorithm. By establishing a finite element model considering the static geometric nonlinearity and stress-stiffening effect firstly, an automatically finite element method model updating powered by PSO algorithm is proposed, with the aims to identify the cable force and relevant parameters of cable-damper system precisely. Both numerical case studies and full-scale cable tests indicated that, after two rounds of updating process, the algorithm can accurately identify the cable force, moment of inertia, and damping coefficient of the cable-damper system.

  9. Design Guidelines of a Spring-Damper System for Emergency Diesel Generator Sets

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Min Kyu; Choun, Young Sun; Seo, Jeong Moon

    2007-05-15

    This guidelines described about the procedure of isolation system design for Emergency Diesel Generator (EDG) of Nuclear Power Plant (NPP). First of all, a vibration concept including the ground vibration was described and vibration control system and seismic isolation system were considered. The behavior characteristics and design consideration of coil spring-viscose damper system were summarized. The material properties of foundation of EDG system and the ground were considered. A design load and seismic load for isolation system design were described and an analysis method was explained. Finally, a design example for an EDG in Yonggwang Nuclear Unit 5 and 6 was attached of Appendix. First of all, this design guideline can apply to design of a vibration and seismic isolation system for EDG system and the design example present a design procedure practically. Moreover, this design guideline can be used for isolation design of other rotational machines and other isolation system except spring-damper system.

  10. An Evaluation of Magneto Rheological Dampers for Controlling Gun Recoil Dynamics

    Directory of Open Access Journals (Sweden)

    Mehdi Ahmadian

    2001-01-01

    Full Text Available The application of magneto rheological dampers for controlling recoil dynamics is examined, using a recoil demonstrator that includes a single-shot 50 caliber BMG rifle action and a MR damper. The demonstrator is selected such that it can adequately represent the velocities that commonly occur in weapons with a recoil system, and can be used for collecting data for analyzing the effects of MR dampers on recoil dynamics. The MR damper is designed so that it can work effectively at the large velocities commonly occurring in gun recoil, and also be easily adjusted to reasonably optimize the damper performance for the recoil demonstrator. The test results show that it is indeed possible to design and use MR dampers for recoil applications, which subject the damper to relative velocities far larger than the applications that such dampers have commonly been used for (i.e., vehicle applications. Further, the results indicate that the recoil force increases and the recoil stroke decreases nonlinearly with an increase in the damping force. Also of significance is the fact that the adjustability of MR dampers can be used in a closed-loop system such that the large recoil forces that commonly occur upon firing the gun are avoided and, simultaneously, the recoil stroke is reduced. This study points to the need for several areas of research including establishing the performance capabilities for MR dampers for gun recoil applications in an exact manner, and the potential use of such dampers for a fire out of battery recoil system.

  11. Nonlinear Squeeze Film Dampers without Centralized Springs

    Directory of Open Access Journals (Sweden)

    Zhu Changsheng

    2000-01-01

    Full Text Available In this paper, the bifurcation behavior of a flexible rotor supported on nonlinear squeeze film dampers without centralized springs is analyzed numerically by means of rotor trajectories, Poincar maps, bifurcation diagrams and power spectra, based on the short bearing and cavitated film assumptions. It is shown that there also exist two different operations (i.e., socalled bistable operations in some speed regions in the rotor system supported on the nonlinear squeeze film dampers without centralized springs. In the bistable operation speed regions, the rotor system exhibits synchronous, sub-synchronous, sub-super-synchronous and almost-periodic as well as nonperiodic motions. The periodic bifurcation behaviors of the rotor system supported on nonlinear squeeze film dampers without centralized springs are very complex and require further investigations.

  12. Seismic Applications of Energy Dampers

    OpenAIRE

    Shambhu Sinha

    2004-01-01

    Damping devices based on the operating principle of high velocity fluid flow through orifices have found numerous applications in the shock and vibration isolation of aerospace and defence systems. The study aims to investigate the feasibility of using energy dissipating fluid viscous dampers in structures to protect against seismic loads and to prove analytically and  experimentally that fluid viscous dampers can improve the seismic capacity of a structure by reducing damage and displacement...

  13. Response of ventilation dampers to large airflow pulses

    International Nuclear Information System (INIS)

    Gregory, W.S.; Smith, P.R.

    1985-04-01

    The results of an experiment program to evaluate the response of ventilation system dampers to simulated tornado transients are reported. Relevant data, such as damper response time, flow rate and pressure drop, and flow/pressure vs blade angle, were obtained, and the response of one tornado protective damper to simulated tornado transients was evaluated. Empirical relationships that will allow the data to be integrated into flow dynamics codes were developed. These flow dynamics codes can be used by safety analysts to predict the response of nuclear facility ventilation systems to tornado depressurization. 3 refs., 21 figs., 6 tabs

  14. Novel design of a self powered and self sensing magneto-rheological damper

    International Nuclear Information System (INIS)

    Ferdaus, Mohammad Meftahul; Rashid, M M; Bhuiyan, M M I; Muthalif, Asan Gani Bin Abdul; Hasan, M R

    2013-01-01

    Magneto-rheological (MR) dampers are semi-active control devices and use MR fluids. Magneto-rheological dampers have successful applications in mechatronics engineering, civil engineering and numerous areas of engineering. At present, traditional MR damper systems, require a isolated power supply and dynamic sensor. This paper presents the achievability and accuracy of a self- powered and self-sensing magneto-rheological damper using harvested energy from the vibration and shock environment in which it is deployed and another important part of this paper is the increased yield stress of the Magneto rheological Fluids. Magneto rheological fluids using replacement of glass beads for Magnetic Particles to surge yield stress is implemented here. Clearly this shows better result on yield stress, viscosity, and settling rate. Also permanent magnet generator (PMG) is designed and attached to a MR damper. For evaluating the self-powered MR damper's vibration mitigating capacity, an Engine Mount System using the MR damper is simulated. The ideal stiffness of the PMG for the Engine Mount System (EMS) is calculated by numerical study. The vibration mitigating performance of the EMS employing the self-powered and self sensing MR damper is theoretically calculated and evaluated in the frequency domain

  15. Novel design of a self powered and self sensing magneto-rheological damper

    Science.gov (United States)

    Meftahul Ferdaus, Mohammad; Rashid, M. M.; Bhuiyan, M. M. I.; Muthalif, Asan Gani Bin Abdul; Hasan, M. R.

    2013-12-01

    Magneto-rheological (MR) dampers are semi-active control devices and use MR fluids. Magneto-rheological dampers have successful applications in mechatronics engineering, civil engineering and numerous areas of engineering. At present, traditional MR damper systems, require a isolated power supply and dynamic sensor. This paper presents the achievability and accuracy of a self- powered and self-sensing magneto-rheological damper using harvested energy from the vibration and shock environment in which it is deployed and another important part of this paper is the increased yield stress of the Magneto rheological Fluids. Magneto rheological fluids using replacement of glass beads for Magnetic Particles to surge yield stress is implemented here. Clearly this shows better result on yield stress, viscosity, and settling rate. Also permanent magnet generator (PMG) is designed and attached to a MR damper. For evaluating the self-powered MR damper's vibration mitigating capacity, an Engine Mount System using the MR damper is simulated. The ideal stiffness of the PMG for the Engine Mount System (EMS) is calculated by numerical study. The vibration mitigating performance of the EMS employing the self-powered & self sensing MR damper is theoretically calculated and evaluated in the frequency domain.

  16. Effect of nonlinearity of connecting dampers on vibration control of connected building structures

    Directory of Open Access Journals (Sweden)

    Masatoshi eKasagi

    2016-01-01

    Full Text Available The connection of two building structures with dampers is one of effective vibration control systems. In this vibration control system, both buildings have to possess different vibration properties in order to provide a higher vibration reduction performance. In addition to such condition of different vibration properties of both buildings, the connecting dampers also play an important role in the vibration control mechanism. In this paper, the effect of nonlinearity of connecting dampers on the vibration control of connected building structures is investigated in detail. A high-damping rubber damper and an oil damper with and without relief mechanism are treated. It is shown that, while the high-damping rubber damper is effective in a rather small deformation level, the linear oil damper is effective in a relatively large deformation level. It is further shown that, while the oil dampers reduce the response in the same phase as the case without dampers, the high-damping rubber dampers change the phase. The merit is that the high-damping rubber can reduce the damper deformation and keep the sufficient space between both buildings. This can mitigate the risk of building pounding.

  17. Stochastic seismic response of building with super-elastic damper

    Science.gov (United States)

    Gur, Sourav; Mishra, Sudib Kumar; Roy, Koushik

    2016-05-01

    Hysteretic yield dampers are widely employed for seismic vibration control of buildings. An improved version of such damper has been proposed recently by exploiting the superelastic force-deformation characteristics of the Shape-Memory-Alloy (SMA). Although a number of studies have illustrated the performance of such damper, precise estimate of the optimal parameters and performances, along with the comparison with the conventional yield damper is lacking. Presently, the optimal parameters for the superelastic damper are proposed by conducting systematic design optimization, in which, the stochastic response serves as the objective function, evaluated through nonlinear random vibration analysis. These optimal parameters can be employed to establish an initial design for the SMA-damper. Further, a comparison among the optimal responses is also presented in order to assess the improvement that can be achieved by the superelastic damper over the yield damper. The consistency of the improvements is also checked by considering the anticipated variation in the system parameters as well as seismic loading condition. In spite of the improved performance of super-elastic damper, the available variant of SMA(s) is quite expensive to limit their applicability. However, recently developed ferrous SMA are expected to offer even superior performance along with improved cost effectiveness, that can be studied through a life cycle cost analysis in future work.

  18. Modeling impact damper in building frames using GAP element

    Directory of Open Access Journals (Sweden)

    Seyed Mehdi Zahrai

    2017-05-01

    Full Text Available Main effective factor in impact dampers to control vibration is to create disruption in structural oscillation amplitude using small forces induced by auxiliary masses to reduce strong vibrations. So far, modeling of the impact damper has been conducted solely through MATLAB software. Naturally, the functional aspects of this software are limited in research and development aspects compared to the common programs such as SAP2000 and ETABS. In this paper, a Single Degree of Freedom System, SDOF, is first modeled under harmonic loading with maximum amplitude of 0.4g in SAP2000 program. Then, the results are compared with numerical model. In this way, the proposed model is validated and the SDOF system equipped with an impact damper is investigated under the Kobe and Northridge earthquake records using SAP2000 model. Based on obtained results, the system equipped with an impact damper under the Kobe and Northridge earthquakes for structures considered in this study would have better seismic performance in which maximum displacements are reduced 6% and 33% respectively. Finally, impact dampers are modeled in a 4-story building structure with concentric bracing leading to 12% reduction in story drifts.

  19. Magnetorheological dampers in shear mode

    International Nuclear Information System (INIS)

    Wereley, N M; Cho, J U; Choi, Y T; Choi, S B

    2008-01-01

    In this study, three types of shear mode damper using magnetorheological (MR) fluids are theoretically analyzed: linear, rotary drum, and rotary disk dampers. The damping performance of these shear mode MR dampers is characterized in terms of the damping coefficient, which is the ratio of the equivalent viscous damping at field-on status to the damping at field-off status. For these three types of shear mode MR damper, the damping coefficient or dynamic range is derived using three different constitutive models: the Bingham–plastic, biviscous, and Herschel–Bulkley models. The impact of constitutive behavior on shear mode MR dampers is theoretically presented and compared

  20. Skylab viscous damper study

    Science.gov (United States)

    1978-01-01

    The proposed magnetically anchored viscous fluid damper can maintain the Skylab in a gravity-gradient stabilized mode at the anticipated reboost altitudes. The parameters influencing damper performance (and thereby affecting the degree of risk) are: (1) amount of skylab pitch bias in the orbit plane which will result from aerodynamic trim conditions of the post-reboost configuration Skylab; (2) the lowest altitude to which the post-reboost Skylab will be allowed to decay prior to the next rendezvous; (3) maximum allowable weight and size of the proposed damper in order to match shuttle/TRS mission constraints; (4) the amount of magnetic materials expected to be in the vicinity of the damper.

  1. Characteristic analysis of the lower limb muscular strength training system applied with MR dampers.

    Science.gov (United States)

    Yu, Chang Ho; Piao, Young Jun; Kim, Kyung; Kwon, Tae Kyu

    2014-01-01

    A new training system that can adjust training intensity and indicate the center pressure of a subject was proposed by applying controlled electric current to the Magneto-Rheological damper. The experimental studying on the muscular activities were performed in lower extremities during maintaining and moving exercises, which were processed on an unstable platform with Magneto rheological dampers and recorded in a monitor. The electromyography (EMG) signals of the eight muscles in lower extremities were recorded and analyzed in certain time and frequency domain. Muscles researched in this paper were rectus femoris (RF), biceps femoris (BF), tensor fasciae latae (TFL), vastuslateralis (VL), vastusmedialis (VM), gastrocnemius (Ga), tibialis anterior (TA), and soleus (So). Differences of muscular activities during four moving exercises were studied in our experimental results. The rate of the increment of the muscular activities was affected by the condition of the unstable platform with MR dampers, which suggested the difference of moving exercises could selectively train each muscle with varying intensities. Furthermore, these findings also proposed that this training system can improve the ability of postural balance.

  2. Pilot Study for Investigating the Cyclic Behavior of Slit Damper Systems with Recentering Shape Memory Alloy (SMA Bending Bars Used for Seismic Restrainers

    Directory of Open Access Journals (Sweden)

    Junwon Seo

    2015-07-01

    Full Text Available Although the steel slit dampers commonly utilized for aseismic design approach can dissipate considerable energy created by the yielding of base materials, large residual deformation may happen in the entire frame structure. After strong external excitation, repair costs will be incurred in restoring a structure to its original condition and to replace broken components. For this reason, alternative recentering devices characterized by smart structures, which mitigate the damage for such steel energy dissipation slit dampers, are developed in this study. These devices, feasibly functioning as seismic restrainers, can be improved by implementing superelastic shape memory alloy (SMA bending bars in a parallel motion with the steel energy-dissipating damper. The bending bars fabricated with superelastic SMAs provide self-centering forces upon unloading, and accordingly contribute to reducing permanent deformation in the integrated slit damper system. The steel slit dampers combined with the superelastic SMA bending bars are evaluated with respect to inelastic behavior as simulated by refined finite element (FE analyses. The FE slit damper models subjected to cyclic loads are calibrated to existing test results in an effort to predict behavior accurately. The responses of the proposed slit damper systems are compared to those of the conventionally used slit damper systems. From the analysis results, it is concluded that innovative steel slit dampers combined with superelastic SMA bending bars generate remarkable performance improvements in terms of post-yield strength, energy dissipation, and recentering capability.

  3. Experimental studies of the effects of buffered particle dampers attached to a multi-degree-of-freedom system under dynamic loads

    Science.gov (United States)

    Lu, Zheng; Lu, Xilin; Lu, Wensheng; Masri, Sami F.

    2012-04-01

    This paper presents a systematic experimental investigation of the effects of buffered particle dampers attached to a multi-degree-of-freedom (mdof) system under different dynamic loads (free vibration, random excitation as well as real onsite earthquake excitations), and analytical/computational study of such a system. A series of shaking table tests of a three-storey steel frame with the buffered particle damper system are carried out to evaluate the performance and to verify the analysis method. It is shown that buffered particle dampers have good performance in reducing the response of structures under dynamic loads, especially under random excitation case. It can effectively control the fundamental mode of the mdof primary system; however, the control effect for higher modes is variable. It is also shown that, for a specific container geometry, a certain mass ratio leads to more efficient momentum transfer from the primary system to the particles with a better vibration attenuation effect, and that buffered particle dampers have better control effect than the conventional rigid ones. An analytical solution based on the discrete element method is also presented. Comparison between the experimental and computational results shows that reasonably accurate estimates of the response of a primary system can be obtained. Properly designed buffered particle dampers can effectively reduce the response of lightly damped mdof primary system with a small weight penalty, under different dynamic loads.

  4. Investigation of optimal seismic design methodology for piping systems supported by elasto-plastic dampers. Part 1. Evaluation functions

    International Nuclear Information System (INIS)

    Ito, Tomohiro; Michiue, Masashi; Fujita, Katsuhisa

    2009-01-01

    In this study, the optimal seismic design methodology that can consider the structural integrity of not only the piping systems but also elasto-plastic supporting devices is developed. This methodology employs a genetic algorithm and can search the optimal conditions such as the supporting location, capacity and stiffness of the supporting devices. Here, a lead extrusion damper is treated as a typical elasto-plastic damper. Four types of evaluation functions are considered. It is found that the proposed optimal seismic design methodology is very effective and can be applied to the actual seismic design for piping systems supported by elasto-plastic dampers. The effectiveness of the evaluation functions is also clarified. (author)

  5. A mechanical energy harvested magnetorheological damper with linear-rotary motion converter

    Science.gov (United States)

    Chu, Ki Sum; Zou, Li; Liao, Wei-Hsin

    2016-04-01

    Magnetorheological (MR) dampers are promising to substitute traditional oil dampers because of adaptive properties of MR fluids. During vibration, significant energy is wasted due to the energy dissipation in the damper. Meanwhile, for conventional MR damping systems, extra power supply is needed. In this paper, a new energy harvester is designed in an MR damper that integrates controllable damping and energy harvesting functions into one device. The energy harvesting part of this MR damper has a unique mechanism converting linear motion to rotary motion that would be more stable and cost effective when compared to other mechanical transmissions. A Maxon motor is used as a power generator to convert the mechanical energy into electrical energy to supply power for the MR damping system. Compared to conventional approaches, there are several advantages in such an integrated device, including weight reduction, ease in installation with less maintenance. A mechanical energy harvested MR damper with linear-rotary motion converter and motion rectifier is designed, fabricated, and tested. Experimental studies on controllable damping force and harvested energy are performed with different transmissions. This energy harvesting MR damper would be suitable to vehicle suspensions, civil structures, and smart prostheses.

  6. Multiphysics modeling of magnetorheological dampers

    Directory of Open Access Journals (Sweden)

    D Case

    2016-09-01

    Full Text Available The dynamics of a small scale magnetorheological damper were modeled and analyzed using multiphysics commercial finite element software to couple the electromagnetic field distribution with the non-Newtonian fluid flow. The magnetic flux lines and field intensity generated within the damper and cyclic fluid flow in the damper under harmonic motion were simulated with the AC/DC and CFD physics modules of COMSOL Multiphysics, respectively. Coupling of the physics is achieved through a modified Bingham plastic definition, relating the fluid's dynamic viscosity to the intensity of the induced magnetic field. Good agreement is confirmed between simulation results and experimentally observed resistance forces in the damper. This study was conducted to determine the feasibility of utilizing magnetorheological dampers in a medical orthosis for pathological tremor attenuation. The implemented models are thus dimensioned on a relatively small scale. The method used, however, is not specific to the damper's size or geometry and can be extended to larger-scale devices with little or no complication.

  7. Active Elastic Support/Dry Friction Damper with Piezoelectric Ceramic Actuator

    Directory of Open Access Journals (Sweden)

    Liao Mingfu

    2014-01-01

    Full Text Available The basic operation principle of elastic support/dry friction damper in rotor system was introduced and the unbalance response of the rotor with elastic support/dry friction damper was analyzed theoretically. Based on the previous structure using an electromagnet as actuator, an active elastic support/dry friction damper using piezoelectric ceramic actuator was designed and its effectiveness of reducing rotor vibration when rotor traverses its critical speed and blade-out event happened was experimentally verified. The experimental results show that the active elastic support/dry friction damper with piezoelectric ceramic actuator can significantly reduce vibration in rotor system; the vibration amplitude of the rotor in critical speed region decreased more than 2 times, and the active damper can protect the rotor when a blade-out event happened, so the rotor can traverse the critical speed and shut down smoothly. In addition, the structure is much simpler than the previous, the weight was reduced by half and the power consumption was only 5 W.

  8. Study on eliminating fire dampers to maintain process confinement

    International Nuclear Information System (INIS)

    Walling, R.C.; Patel, J.B.; Strunk, A.J.

    1991-01-01

    The DOE General Design Criteria for the Defense Waste Processing Facility (DWPF) at the Westinghouse Savannah River Site (WSRS) requires the NFPA National Fire Codes to be incorporated into the design and simultaneously maintain process confinement integrity to prevent the release of radioactivity. Although the NFPA Standard for the Installation of Air Conditioning and Ventilation Systems, NFPA 90, requires fire dampers (FD) in HVAC duct penetrations of two hour rated fire barriers, closure of fire dampers at DWPF may compromise the integrity of the process confinement system. This leads to the need for an overall risk assessment to determine the value of 39 fire dampers that are identified later in the study as capable of a confinement system upset

  9. Experimental Study of under-platform Damper Kinematics in Presence of Blade Dynamics

    Science.gov (United States)

    Botto, D.; Gastaldi, C.; Gola, M. M.; Umer, M.

    2018-01-01

    Among the different devices used in the aerospace industries under-platform dampers are widely used in turbo engines to mitigate the blade vibration. Nevertheless, the damper behaviour is not easy to simulate and engineers have been working in order to improve the accuracy with which theoretical contact models predict the damper behaviour. Majority of the experimental setups collect experimental data in terms of blade amplitude reduction which do not increase the knowledge about the damper dynamics and therefore the uncertainty on the damper behaviour remains a big issue. In this paper, a novel test rig has been purposely designed to accommodate a single blade and two under-platform dampers to deeply investigate the damper-blade interactions. In this test bench, a contact force measuring system was designed to extensively measure the damper contact forces. Damper kinematics is rebuilt by using the relative displacement measured between damper and blade. This paper describes the concept behind the new approach, shows the details of new test rig and discusses experimental results by comparing with previously measured results on an old experimental setup.

  10. Modelling of Dampers and Damping in Structures

    DEFF Research Database (Denmark)

    Høgsberg, Jan Riess

    2006-01-01

    and the maximum attainable damping are found by maximizing the expression for the damping ratio. The theory is formulated for linear damper models, but may also be applied for non-linear dampers in terms of equivalent linear parameters for stiffness and damping, respectively. The format of the expressions......, and thereby the damping, of flexible structures are generally described in terms of the dominant vibration modes. A system reduction technique, where the damped vibration mode is constructed as a linear combination of the undamped mode shape and the mode shape obtained by locking the damper, is applied....... This two-component representation leads to a simple solution for the modal damping representing the natural frequency and the associated damping ratio. It appears from numerical examples that this system reduction technique provides very accurate results. % Analytical expressions for the optimal tuning...

  11. Invention of a tunable damper for use with an acoustic waveguide in hostile environments

    International Nuclear Information System (INIS)

    Rogers, S.C.

    1984-06-01

    A damper was invented to remove undesirable stress pulses from an acoustic waveguide. Designed to be tunable, the damper was constructed to withstand a corrosive or otherwise hostile environment. It serves to simplify the design and enhance the performance of a water-level measurement system, of which the damper and acoustic waveguide are integral parts. An experimental damper was constructed and applied to an existing level probe and measurement system. The resulting damper, properly tuned, causes acoustic stress pulses that pass into it along the waveguide to be attenuated

  12. Numerical Model of a Hybrid Damping System Composed of a Buckling Restrained Brace with a Magneto Rheological Damper

    Directory of Open Access Journals (Sweden)

    Filip-Vacarescu Norin

    2016-03-01

    Full Text Available This paper discusses the concept of a hybrid damper made from a combination of two dissipative devices. A passive hysteretic device like steel Buckling Restrained Brace (BRB can be combined with a magneto-rheological (MR Fluid Damper in order to obtain a hybrid dissipative system. This system can work either as a semi-active system, if the control unit is available, or as a passive system, tuned for working according to performance based seismic engineering (PBSE scale of reference parameters (i.e. interstory drift.

  13. Control strategies for friction dampers: numerical assessment and experimental investigations.

    Directory of Open Access Journals (Sweden)

    Coelho H.T.

    2014-01-01

    Full Text Available The use of friction dampers has been proposed in a wide variety of mechanical systems for which it is not possible to apply viscoelastic materials, fluid based dampers or others viscous dampers. An important example is the application of friction dampers in aircraft engines to reduce the blades vibration amplitudes. In most cases, friction dampers have been studied in a passive way, however, a significant improvement can be achieved by controlling the normal force in the dampers. The aim of this paper is to study three control strategies for friction dampers based on the hysteresis cycle. The first control strategy maximizes the energy removal in each harmonic oscillation cycle, by calculating the optimum normal force based on the last displacement peak. The second control strategy combines the first one with the maximum energy removal strategy used in the smart spring devices. Finally, is presented the strategy which homogenously modulates the friction force. Numerical studies were performed with these three strategies defining the performance metrics. The best control strategy was applied experimentally. The experimental test rig was fully identified and its parameters were used for the numerical simulations. The obtained results show the good performance for the friction damper and the selected strategy.

  14. Optimal inverse magnetorheological damper modeling using shuffled frog-leaping algorithm–based adaptive neuro-fuzzy inference system approach

    Directory of Open Access Journals (Sweden)

    Xiufang Lin

    2016-08-01

    Full Text Available Magnetorheological dampers have become prominent semi-active control devices for vibration mitigation of structures which are subjected to severe loads. However, the damping force cannot be controlled directly due to the inherent nonlinear characteristics of the magnetorheological dampers. Therefore, for fully exploiting the capabilities of the magnetorheological dampers, one of the challenging aspects is to develop an accurate inverse model which can appropriately predict the input voltage to control the damping force. In this article, a hybrid modeling strategy combining shuffled frog-leaping algorithm and adaptive-network-based fuzzy inference system is proposed to model the inverse dynamic characteristics of the magnetorheological dampers for improving the modeling accuracy. The shuffled frog-leaping algorithm is employed to optimize the premise parameters of the adaptive-network-based fuzzy inference system while the consequent parameters are tuned by a least square estimation method, here known as shuffled frog-leaping algorithm-based adaptive-network-based fuzzy inference system approach. To evaluate the effectiveness of the proposed approach, the inverse modeling results based on the shuffled frog-leaping algorithm-based adaptive-network-based fuzzy inference system approach are compared with those based on the adaptive-network-based fuzzy inference system and genetic algorithm–based adaptive-network-based fuzzy inference system approaches. Analysis of variance test is carried out to statistically compare the performance of the proposed methods and the results demonstrate that the shuffled frog-leaping algorithm-based adaptive-network-based fuzzy inference system strategy outperforms the other two methods in terms of modeling (training accuracy and checking accuracy.

  15. Optimization analysis of a new vane MRF damper

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, J Q; Feng, Z Z; Jing, Q [Department of Technical Support Engineering, Academy of Armored Force Engineering, Beijing, 100072 (China)], E-mail: zhangjq63@yahoo.com.cn

    2009-02-01

    The primary purpose of this study was to provide the optimization analysis certain characteristics and benefits of a vane MRF damper. Based on the structure of conventional vane hydraulic damper for heavy vehicle, a narrow arc gap between clapboard and rotary vane axle, which one rotates relative to the other, was designed for MRF valve and the mathematical model of damping was deduced. Subsequently, the finite element analysis of electromagnetic circuit was done by ANSYS to perform the optimization process. Some ways were presented to augment the damping adjustable multiple under the condition of keeping initial damping forces and to increase fluid dwell time through the magnetic field. The results show that the method is useful in the design of MR dampers and the damping adjustable range of vane MRF damper can meet the requirement of heavy vehicle semi-active suspension system.

  16. Optimum design of a Lanchester damper for a viscously damped single degree of freedom system subjected to inertial excitation

    Science.gov (United States)

    Bapat, V. A.; Prabhu, P.

    1980-11-01

    The problem of designing an optimum Lanchester damper for a viscously damped single degree of freedom system subjected to inertial harmonic excitation is investigated. Two criteria are used for optimizing the performance of the damper: (i) minimum motion transmissibility; (ii) minimum force transmissibility. Explicit expressions are developed for determining the absorber parameters.

  17. Vibration isolation analysis of new design OEM damper for malaysia vehicle suspension system featuring MR fluid

    Science.gov (United States)

    Unuh, M. H.; Muhamad, P.; Norfazrina, H. M. Y.; Ismail, M. A.; Tanasta, Z.

    2018-01-01

    The applications of semi-active damper employing magnetorheological (MR) fluids keep increasing in fulfilling the demand to control undesired vibration effect. The aim of this study is to introduce the new design of damper for Malaysian vehicle model as well to evaluate its effectiveness in promoting comfort. The vibration isolation performance of the OEM damper featuring MR fluid was analysed physically under real road profile excitation experimentally. An experiment using quarter car rig suspension and LMS SCADAS Mobile was conducted to demonstrate the influence of current in controlling the characteristics of MR fluid in alter the damping behaviour under 5 cm bump impact. Subsequently, the displacement values were measured with respect to time. The new design OEM damper featuring MR fluid was validated by comparing the data with original equipment manufacturer (OEM) passive damper results under the same approach of testing. Comparison of numerical data of the new design OEM damper shown that it can reduce the excitation amplitude up to 40% compared to those obtained by OEM passive damper. Finally, the new design OEM damper featuring MR fluid has effectively isolated the disturbance from the road profile and control the output force.

  18. A hybrid damping method for LLCL-filter based grid-tied inverter with a digital filter and an RC parallel passive damper

    DEFF Research Database (Denmark)

    Wu, Weimin; Lin, Zhe; Sun, Yunjie

    2013-01-01

    Grid-tied inverters have been widely used to inject the renewable energies into the distributed power generation systems. However, a large variation of the grid impedance challenges the stability of the high-order power filter based grid-tied inverter. Many passive and active damping methods have...... been proposed to overcome this issue. Recently, a composite passive damping method for a high-order power filter based grid-tied inverter with an RC parallel damper and an RL series damper was presented to eliminate this problem, but at the cost of more material and power losses. In this paper...

  19. Response of piping system with semi-active variable stiffness damper under tri-directional seismic excitation

    International Nuclear Information System (INIS)

    Praveen Kumar; Jangid, R.S.; Reddy, G.R.

    2013-01-01

    Highlights: ► Piping system with semi-active variable stiffness damper is investigated under different seismic excitations. ► Switching control law and modified switching control law are adopted. ► There exist an optimum parameters of the SAVSD. ► Substantial reduction of the seismic response of piping system with SAVSD is observed. ► Good amount of energy dissipation is observed. -- Abstract: Seismic loads on piping system due to earthquakes can cause excessive vibrations, which can lead to serious instability resulting in damage or complete failure. In this paper, semi-active variable stiffness dampers (SAVSDs) have been studied to mitigate seismic response and vibration control of piping system used in the process industries, fossil and fissile fuel power plant. The SAVSD changes its stiffness depending upon the piping response and accordingly adds the control forces in the piping system. A study is conducted on the performance of SAVSD due to variation in device stiffness ratios in the switching control law and modified switching control law, which plays an important role in the present control algorithm of the damper. The effectiveness of the SAVSD in terms of reduction in the responses, namely, displacements, accelerations and base shear of the piping system is investigated by comparing uncontrolled responses under four different artificial earthquake motions with increasing amplitudes. The analytical results demonstrate that the SAVSDs under particular optimum parameters are very effective and practically implementable for the seismic response mitigation, vibration control and seismic requalification of piping systems

  20. Response of piping system with semi-active variable stiffness damper under tri-directional seismic excitation

    Energy Technology Data Exchange (ETDEWEB)

    Praveen Kumar, E-mail: praveen@barc.gov.in [Department of Civil Engineering, Indian Institute of Technology Bombay, Powai, Mumbai 400076 (India); Bhabha Atomic Research Centre, Trombay, Mumbai 400085 (India); Jangid, R.S. [Department of Civil Engineering, Indian Institute of Technology Bombay, Powai, Mumbai 400076 (India); Reddy, G.R. [Bhabha Atomic Research Centre, Trombay, Mumbai 400085 (India)

    2013-05-15

    Highlights: ► Piping system with semi-active variable stiffness damper is investigated under different seismic excitations. ► Switching control law and modified switching control law are adopted. ► There exist an optimum parameters of the SAVSD. ► Substantial reduction of the seismic response of piping system with SAVSD is observed. ► Good amount of energy dissipation is observed. -- Abstract: Seismic loads on piping system due to earthquakes can cause excessive vibrations, which can lead to serious instability resulting in damage or complete failure. In this paper, semi-active variable stiffness dampers (SAVSDs) have been studied to mitigate seismic response and vibration control of piping system used in the process industries, fossil and fissile fuel power plant. The SAVSD changes its stiffness depending upon the piping response and accordingly adds the control forces in the piping system. A study is conducted on the performance of SAVSD due to variation in device stiffness ratios in the switching control law and modified switching control law, which plays an important role in the present control algorithm of the damper. The effectiveness of the SAVSD in terms of reduction in the responses, namely, displacements, accelerations and base shear of the piping system is investigated by comparing uncontrolled responses under four different artificial earthquake motions with increasing amplitudes. The analytical results demonstrate that the SAVSDs under particular optimum parameters are very effective and practically implementable for the seismic response mitigation, vibration control and seismic requalification of piping systems.

  1. Evaluation of shear mounted elastomeric damper

    Science.gov (United States)

    Zorzi, E.; Walton, J.

    1982-01-01

    Viton-70 elastomeric shear mounted damper was built and tested on a T-55 power turbine spool in the rotor's high speed balancing rig. This application of a shear mounted elastomeric damper demonstrated for the first time, the feasibility of using elastomers as the primary rotor damping source in production turbine engine hardware. The shear damper design was selected because it was compatible with actual gas turbine engine radial space constraints, could accommodate both the radial and axial thrust loads present in gas turbine engines, and was capable of controlled axial preload. The shear damper was interchangeable with the production T-55 power turbine roller bearing support so that a direct comparison between the shear damper and the production support structure could be made. Test results show that the Viton-70 elastomer damper operated successfully and provided excellent control of both synchronous and nonsynchronous vibrations through all phases of testing up to the maximum rotor speed of 16,000 rpm. Excellent correlation between the predicted and experienced critical speeds, mode shapes and log decrements for the power turbine rotor and elastomer damper assembly was also achieved.

  2. The Effective Design of Bean Bag as a Vibroimpact Damper

    Directory of Open Access Journals (Sweden)

    A.Q. Liu

    2000-01-01

    Full Text Available The technique of a bean bag damper has been effectively applied in many engineering fields to control the vibroimpact of a structural system. In this study, the basic parameters responsible for the design of an effective bean bag: the size of beans, the mass ratio of the bean bag to the structure to which it is attached, the clearance distance and the position of the bag, are studied by both theoretical and experimental analyses. These will provide a better understanding of the performance of the bean bag for optimisation of damper design. It was found that reducing the size of beans would increase the exchange of momentum in the system due to the increase in the effective contact areas. Within the range of mass ratios studied, the damping performance of the damper was found to improve with higher mass ratios. There was an optimum clearance for any specific damper whereby the maximum attenuation could be achieved. The position of the bag with respect to nodes and antipodes of the primary structure determined the magnitude of attenuation attainable. Furthermore, the limitations of bean bags have been identified and a general criteria for the design of a bean bag damper has been formulated based on the study undertaken. It was shown that an appropriately configured bean bag damper was capable of reducing the amplitude of vibration by 80% to 90%.

  3. Design method for fluid viscous dampers

    Energy Technology Data Exchange (ETDEWEB)

    Jia, Jiuhong; Hua, Hongxing [Shanghai Jiaotong University, State Key Laboratory of Mechanical System and Vibration, Shanghai (China); Du, Jianye; Wang, Yu [Naval Arming Academy, Institute of Naval Vessels, Beijing (China)

    2008-09-15

    A basic design method of doubly acting fluid viscous dampers with double guide bars is presented. The flow of the viscoelastic fluid between two parallel plates, one of which is started suddenly and the other of which is still, is analyzed. According to this solution, the velocity and the shear stress of the fluid at the fringe of the piston are solved approximately. A mathematical model of viscous dampers is derived, and the shock test is carried out. From experimental results, the parameters of the mathematical model are determined. Consequently, a semi-empirical design equation is obtained. Applying this equation to a certain practical damper, the damping material is chosen and the physical dimensions of the damper are determined. Shock tests using this damper are performed. Theoretical results are in good agreement with experimental results, which validates the reliability of the calculated physical dimensions of the specimen damper and the validity of the basic design equation. (orig.)

  4. Dynamic characteristics of stay cables with inerter dampers

    Science.gov (United States)

    Shi, Xiang; Zhu, Songye

    2018-06-01

    This study systematically investigates the dynamic characteristics of a stay cable with an inerter damper installed close to one end of a cable. The interest in applying inerter dampers to stay cables is partially inspired by the superior damping performance of negative stiffness dampers in the same application. A comprehensive parametric study on two major parameters, namely, inertance and damping coefficients, are conducted using analytical and numerical approaches. An inerter damper can be optimized for one vibration mode of a stay cable by generating identical wave numbers in two adjacent modes. An optimal design approach is proposed for inerter dampers installed on stay cables. The corresponding optimal inertance and damping coefficients are summarized for different damper locations and interested modes. Inerter dampers can offer better damping performance than conventional viscous dampers for the target mode of a stay cable that requires optimization. However, additional damping ratios in other vibration modes through inerter damper are relatively limited.

  5. Modeling and analysis of a novel planar eddy current damper

    Science.gov (United States)

    Zhang, He; Kou, Baoquan; Jin, Yinxi; Zhang, Lu; Zhang, Hailin; Li, Liyi

    2014-05-01

    In this paper, a novel 2-DOF permanent magnet planar eddy current damper is proposed, of which the stator is made of a copper plate and the mover is composed of two orthogonal 1-D permanent magnet arrays with a double sided structure. The main objective of the planar eddy current damper is to provide two orthogonal damping forces for dynamic systems like the 2-DOF high precision positioning system. Firstly, the basic structure and the operating principle of the planar damper are introduced. Secondly, the analytical model of the planar damper is established where the magnetic flux density distribution of the permanent magnet arrays is obtained by using the equivalent magnetic charge method and the image method. Then, the analytical expressions of the damping force and damping coefficient are derived. Lastly, to verify the analytical model, the finite element method (FEM) is adopted for calculating the flux density and a planar damper prototype is manufactured and thoroughly tested. The results from FEM and experiments are in good agreement with the ones from the analytical expressions indicating that the analytical model is reasonable and correct.

  6. Semi-active H∞ control of high-speed railway vehicle suspension with magnetorheological dampers

    Science.gov (United States)

    Zong, Lu-Hang; Gong, Xing-Long; Xuan, Shou-Hu; Guo, Chao-Yang

    2013-05-01

    In this paper, semi-active H∞ control with magnetorheological (MR) dampers for railway vehicle suspension systems to improve the lateral ride quality is investigated. The proposed semi-active controller is composed of a H∞ controller as the system controller and an adaptive neuro-fuzzy inference system (ANFIS) inverse MR damper model as the damper controller. First, a 17-degree-of-freedom model for a full-scale railway vehicle is developed and the random track irregularities are modelled. Then a modified Bouc-Wen model is built to characterise the forward dynamic characteristics of the MR damper and an inverse MR damper model is built with the ANFIS technique. Furthermore, a H∞ controller composed of a yaw motion controller and a rolling pendulum motion (lateral motion+roll motion) controller is established. By integrating the H∞ controller with the ANFIS inverse model, a semi-active H∞ controller for the railway vehicle is finally proposed. Simulation results indicate that the proposed semi-active suspension system possesses better attenuation ability for the vibrations of the car body than the passive suspension system.

  7. An adaptive tuned mass damper based on the emulation of positive and negative stiffness with an MR damper

    International Nuclear Information System (INIS)

    Weber, F; Boston, C; Maślanka, M

    2011-01-01

    This paper presents a new adaptive tuned mass damper (TMD) whose stiffness and damping can be tuned in real-time to changing frequencies of a target structure. The adaptive TMD consists of a tuned mass, a tuned passive spring and a magnetorheological (MR) damper. The MR damper is used to emulate controlled friction–viscous damping and controlled stiffness. The controlled positive or negative stiffness emulated by the MR damper works in parallel to the stiffness of the passive TMD spring. The resulting overall TMD stiffness can therefore be varied around the passive spring stiffness using the MR damper. Both the emulated stiffness and friction–viscous damping in the MR damper are controlled such that the resulting overall TMD stiffness and damping are adjusted according to Den Hartog's formulae. Simulations demonstrate that the adaptive TMD with a controlled MR damper provides the same reduction of steady state vibration amplitudes in the target structure as a passive TMD if the target structure vibrates at the nominal frequency. However, if the target structure vibrates at different frequencies, e.g. due to changed service loads, the adaptive TMD with a controlled MR damper outperforms the passive TMD by up to several 100% depending on the frequency change

  8. Fermilab 500 GeV main accelerator rf cavity 128 MHz mode damper

    International Nuclear Information System (INIS)

    Kerns, Q.A.; Miller, H.W.

    1977-01-01

    The Fermilab 500-GeV main accelerating system has been operating for a year now with the aid of 128-MHz mode dampers. Such dampers proved to be necessary to achieve stable operation and a reasonably smooth slow spill at intensities of approximately 2 x 10 13 protons per pulse, and furthermore are low-cost and reliable. The approach used to identify troublesome modes, the observed beam blow-up without dampers, and the steps taken to design and install suitable dampers on eighteen main ring cavities are discussed. Spectrum analyzer pictures help illustrate the performance

  9. The stability of the damper system for the coherent transverse oscillations of the beam in a synchrotron

    International Nuclear Information System (INIS)

    Zhabitskij, V.M.; Korenev, I.L.; Yudin, L.A.

    1991-01-01

    The investigation of the direct alternating kicker current perturbation influence of the particle motion in synchrotron with the beam coherent transverse oscillation damper in feedback are obtained. It has been shown that for a some pick-up and kicker placements are impossible due to this reason. The resonance conditions and their dependences on feedback gain-transfer characteristic have been found. The numerical results are given for the damper systems in UNK-1 and LHC. 6 refs.; 5 figs

  10. Vibration power generator for a linear MR damper

    International Nuclear Information System (INIS)

    Sapiński, Bogdan

    2010-01-01

    The paper describes the structure and the results of numerical calculations and experimental tests of a newly developed vibration power generator for a linear magnetorheological (MR) damper. The generator consists of permanent magnets and coil with foil winding. The device produces electrical energy according to Faraday's law of electromagnetic induction. This energy is applied to vary the damping characteristics of the MR damper attached to the generator by the input current produced by the device. The objective of the numerical calculations was to determine the magnetic field distribution in the generator as well as the electric potential and current density in the generator's coil during the idle run and under the load applied to the MR damper control coil. The results of the calculations were used during the design and manufacturing stages of the device. The objective of the experimental tests carried out on a dynamic testing machine was to evaluate the generator's efficiency and to compare the experimental and predicted data. The experimental results demonstrate that the engineered device enables a change in the kinetic energy of the reciprocal motion of the MR damper which leads to variations in the damping characteristics. That is why the generator may be used to build up MR damper based vibration control systems which require no external power

  11. Design and parametric study on energy harvesting from bridge vibration using tuned dual-mass damper systems

    Science.gov (United States)

    Takeya, Kouichi; Sasaki, Eiichi; Kobayashi, Yusuke

    2016-01-01

    A bridge vibration energy harvester has been proposed in this paper using a tuned dual-mass damper system, named hereafter Tuned Mass Generator (TMG). A linear electromagnetic transducer has been applied to harvest and make use of the unused reserve of energy the aforementioned damper system absorbs. The benefits of using dual-mass systems over single-mass systems for power generation have been clarified according to the theory of vibrations. TMG parameters have been determined considering multi-domain parameters, and TMG has been tuned using a newly proposed parameter design method. Theoretical analysis results have shown that for effective energy harvesting, it is essential that TMG has robustness against uncertainties in bridge vibrations and tuning errors, and the proposed parameter design method for TMG has demonstrated this feature.

  12. Magnetorheological fluid dampers: a review of parametric modelling

    International Nuclear Information System (INIS)

    Wang, D H; Liao, W H

    2011-01-01

    Due to the inherent nonlinear nature of magnetorheological (MR) dampers, one of the challenging aspects for developing and utilizing these devices to achieve high performance is the development of models that can accurately describe their unique characteristics. In this review, the characteristics of MR dampers are summarized according to the measured responses under different conditions. On these bases, the considerations and methods of the parametric dynamic modelling for MR dampers are given and the state-of-the-art parametric dynamic modelling, identification and validation techniques for MR dampers are reviewed. In the past two decades, the models for MR dampers have been focused on how to improve the modelling accuracy. Although the force–displacement behaviour is well represented by most of the proposed dynamic models for MR dampers, no simple parametric models with high accuracy for MR dampers can be found. In addition, the parametric dynamic models for MR dampers with on-line updating ability and the inverse parametric models for MR dampers are scarcely explored. Moreover, whether one dynamic model for MR dampers can portray the force–displacement and force–velocity behaviour is not only determined by the dynamic model itself but also determined by the identification method. (topical review)

  13. Dampers for Stationary Labyrinth Seals

    Science.gov (United States)

    El-Aini, Yehia; Mitchell, William; Roberts, Lawrence; Montgomery, Stuart; Davis, Gary

    2011-01-01

    Vibration dampers have been invented that are incorporated as components within the stationary labyrinth seal assembly. These dampers are intended to supplement other vibration-suppressing features of labyrinth seals in order to reduce the incidence of high-cycle-fatigue failures, which have been known to occur in the severe vibratory environments of jet engines and turbopumps in which labyrinth seals are typically used. A vibration damper of this type includes several leaf springs and/or a number of metallic particles (shot) all held in an annular seal cavity by a retaining ring. The leaf springs are made of a spring steel alloy chosen, in conjunction with design parameters, to maintain sufficient preload to ensure effectiveness of damping at desired operating temperatures. The cavity is vented via a small radial gap between the retaining ring and seal housing. The damping mechanism is complex. In the case of leaf springs, the mechanism is mainly friction in the slippage between the seal housing and individual dampers. In the case of a damper that contains shot, the damping mechanism includes contributions from friction between individual particles, friction between particles and cavity walls, and dissipation of kinetic energy of impact. The basic concept of particle/shot vibration dampers has been published previously; what is new here is the use of such dampers to suppress traveling-wave vibrations in labyrinth seals. Damping effectiveness depends on many parameters, including, but not limited to, coefficient of friction, mode shape, and frequency and amplitude of vibrational modes. In tests, preloads of the order of 6 to 15 lb (2.72 to 6.8 kilograms) per spring damper were demonstrated to provide adequate damping levels. Effectiveness of shot damping of vibrations having amplitudes from 20 to 200 times normal terrestrial gravitational acceleration (196 to 1,960 meters per square second) and frequencies up to 12 kHz was demonstrated for shot sizes from 0.032 to

  14. Experimental Investigation of the Dynamic Response of Squeeze Film Dampers Made of Steel and Glass/Epoxy

    Directory of Open Access Journals (Sweden)

    Waleed F. Faris

    2008-01-01

    Full Text Available This work is devoted to the fabrication and investigation of the Squeeze Film Dampers (SFDs which are widely used in many applications. This include the fabrication of a test rig and several dampers with different sizes and two different materials which composite and non-composite. Composite dampers (Glass/epoxy, each consists of 30 layers, were fabricated by hand lay-up method. Outer and inner diameters of all the fabricated dampers were maintained as 60 and 40 mm respectively. Non-composite dampers (Steel were fabricated and tested using turning machine. Three dampers of different lengths were examined for both materials. A rotor-bearing system for the analysis has been designed and fabricated. The test rig consists of mild steel shaft, two supports, oil pressure system, and two self-alignment ball bearings were fixed on each end support. Two squeeze film dampers were used for the two support ends. Vibration amplitude has been examined for all the fabricated dampers at different shaft rotational speeds. The first resonance speed was examined for all the dampers tested. Results show that the vibration amplitude of the steel damper was lower than Glass/epoxy dampers with the same L/D ratio. On the other hand, a considerable weight saving has been achieved by using Glass/epoxy composite dampers. It has been found that the performance of squeeze film damper improved with increasing length/diameter ratio (L/D within the range tested.

  15. A fully dynamic magneto-rheological fluid damper model

    International Nuclear Information System (INIS)

    Jiang, Z; Christenson, R E

    2012-01-01

    Control devices can be used to dissipate the energy of a civil structure subjected to dynamic loading, thus reducing structural damage and preventing failure. Semiactive control devices have received significant attention in recent years. The magneto-rheological (MR) fluid damper is a promising type of semiactive device for civil structures due to its mechanical simplicity, inherent stability, high dynamic range, large temperature operating range, robust performance, and low power requirements. The MR damper is intrinsically nonlinear and rate-dependent, both as a function of the displacement across the MR damper and the command current being supplied to the MR damper. As such, to develop control algorithms that take maximum advantage of the unique features of the MR damper, accurate models must be developed to describe its behavior for both displacement and current. In this paper, a new MR damper model that includes a model of the pulse-width modulated (PWM) power amplifier providing current to the damper, a proposed model of the time varying inductance of the large-scale 200 kN MR dampers coils and surrounding MR fluid—a dynamic behavior that is not typically modeled—and a hyperbolic tangent model of the controllable force behavior of the MR damper is presented. Validation experimental tests are conducted with two 200 kN large-scale MR dampers located at the Smart Structures Technology Laboratory (SSTL) at the University of Illinois at Urbana-Champaign and the Lehigh University Network for Earthquake Engineering Simulation (NEES) facility. Comparison with experimental test results for both prescribed motion and current and real-time hybrid simulation of semiactive control of the MR damper shows that the proposed MR damper model can accurately predict the fully dynamic behavior of the large-scale 200 kN MR damper. (paper)

  16. Force Feedback Control Method of Active Tuned Mass Damper

    Directory of Open Access Journals (Sweden)

    Xiuli Wang

    2017-01-01

    Full Text Available Active tuned mass dampers as vibration-control devices are widely used in many fields for their good stability and effectiveness. To improve the performance of such dampers, a control method based on force feedback is proposed. The method offers several advantages such as high-precision control and low-performance requirements for the actuator, as well as not needing additional compensators. The force feedback control strategy was designed based on direct-velocity feedback. The effectiveness of the method was verified in a single-degree-of-freedom system, and factors such as damping effect, required active force, actuator stroke, and power consumption of the damper were analyzed. Finally, a simulation study was performed by configuring a main complex elastic-vibration-damping system. The results show that the method provides effective control over modal resonances of multiple orders of the system and improves its dynamics performance.

  17. Modelling and Experimental Investigation of an Active Damper

    Directory of Open Access Journals (Sweden)

    Rafael Luís Teixeira

    2006-01-01

    Full Text Available This paper presents a validation methodology of the dynamic behavior of an active viscous damper. The damper has two flexible metallic bellows connected to a rigid reservoir filled with fluid. When one of the bellows is connected to a vibrating structure a periodic flow passes through a variable internal orifice and the damping effect is produced. The size of the orifice is adjusted by a controlled linear piezoelectric actuator that positions the conical core into a conical cavity. The device finite element structural model consists of the valve body and its conical core that are assumed rigid and the flexible bellows are represented by two pistons with elastic suspensions. The flow developed inside the damper is modeled considering the fluid-structure interation, using the Lagrangean-Eulerian formulation. To validate the proposed model a prototype was constructed and experimental tests and numerical simulations are accomplished in the time domain, applying harmonic excitations. The results are compared using curves that relate the damping coefficient with the orifice size and with the input velocity applied at the bellows face. However, for the proper control design and system operation, the direct use of the finite element model becomes unviable due to its high computational time. Then, a reduced second order discrete dynamic model for the damper was developed. The model parameters are identified by analysis in the frequency domain, using impulsive excitation force, for constant and variable orifice sizes. At low excitation frequencies, the damper prototype behaves like a single degree of freedom system which damping factor changes with the orifice size A fuzzy controller was designed and it generates the orifice reference size associated to the desired damping factor. The active system presented better performance when compared to the passive one.

  18. Modeling and control of magnetorheological fluid dampers using neural networks

    Science.gov (United States)

    Wang, D. H.; Liao, W. H.

    2005-02-01

    Due to the inherent nonlinear nature of magnetorheological (MR) fluid dampers, one of the challenging aspects for utilizing these devices to achieve high system performance is the development of accurate models and control algorithms that can take advantage of their unique characteristics. In this paper, the direct identification and inverse dynamic modeling for MR fluid dampers using feedforward and recurrent neural networks are studied. The trained direct identification neural network model can be used to predict the damping force of the MR fluid damper on line, on the basis of the dynamic responses across the MR fluid damper and the command voltage, and the inverse dynamic neural network model can be used to generate the command voltage according to the desired damping force through supervised learning. The architectures and the learning methods of the dynamic neural network models and inverse neural network models for MR fluid dampers are presented, and some simulation results are discussed. Finally, the trained neural network models are applied to predict and control the damping force of the MR fluid damper. Moreover, validation methods for the neural network models developed are proposed and used to evaluate their performance. Validation results with different data sets indicate that the proposed direct identification dynamic model using the recurrent neural network can be used to predict the damping force accurately and the inverse identification dynamic model using the recurrent neural network can act as a damper controller to generate the command voltage when the MR fluid damper is used in a semi-active mode.

  19. Design and testing of a MRF rotational damper for vehicle applications

    International Nuclear Information System (INIS)

    Giorgetti, A; Baldanzini, N; Citti, P; Biasiotto, M

    2010-01-01

    Adaptive dampers are an interesting solution for conjugating the necessity of controllable devices and low power consumption. Magneto-rheological fluids (MRF) can be profitably employed in adaptive dampers because of the significant variation of fluid parameters with magnetic field properties. This paper focuses on the design process of an innovative rotational MR damper specifically created to be placed in the front-wheel suspension of a compact car. The advantages of the rotational damper and the definition of the optimal design are described. The proposed damper significantly reduces several key problems associated with MR devices: the quantity of fluid required, the sedimentation of ferromagnetic particles in the suspension and the abrasion of the seals. In fact, with this solution, low average working pressure, low flow velocity through valves, a wide range of variable damping characteristics, and high durability of the damper can be achieved. Thanks to this innovative component, different new architectures for adaptive suspension systems can be developed to have a planar distribution of the suspension components with a consequent space optimization and size reduction in the vertical direction

  20. Longitudinally Vibrating Elastic Rods with Locally and Non-Locally Reacting Viscous Dampers

    Directory of Open Access Journals (Sweden)

    Şefaatdin Yüksel

    2005-01-01

    Full Text Available Eigencharacteristics of a longitudinally vibrating elastic rod with locally and non-locally reacting damping are analyzed. The rod is considered as a continuous system and complex eigenfrequencies are determined as solution of a characteristic equation. The variation of the damping ratios with respect to damper locations and damping coefficients for the first four eigenfrequencies are obtained. It is shown that at any mode of locally or non-locally damped elastic rod, the variation of damping ratio with damper location is linearly proportional to absolute value of the mode shape of undamped system. It is seen that the increasing damping coefficient does not always increase the damping ratio and there are optimal values for the damping ratio. Optimal values for external damping coefficients of viscous dampers and locations of the dampers are presented.

  1. Mathematical modelling of the mass-spring-damper system - A fractional calculus approach

    Directory of Open Access Journals (Sweden)

    Jesus Bernal Alvarado

    2012-08-01

    Full Text Available In this paper the fractional differential equation for the mass-spring-damper system in terms of the fractional time derivatives of the Caputo type is considered. In order to be consistent with the physical equation, a new parameter is introduced. This parameter char­acterizes the existence of fractional components in the system. A relation between the fractional order time derivative and the new parameter is found. Different particular cases are analyzed

  2. Analytical Model of Coil Spring Damper Based on the Loading Test

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Sung Gook; Park, Woong Ki [INNOSE TECH Co. LTD, Incheon (Korea, Republic of); Furuya, Osamu [Tokyo City University, Tokyo (Japan); Kurabayashi, Hiroshi [Vibro-System, Tokyo (Japan)

    2016-05-15

    The one way of solving such problems is to enhance and to develop an improved damping element used in base-isolation and response control system. A cost reduction of damper for a large scale structure is another important task to upgrade the total response control abilities in the near future. This study has examined a response control device using elastoplastic hysteresis damping of metal material. The proposed damper is designed to be coil spring element shape for a uniform stress of metal and for a reduction of low cyclic fatigue in large deformation to upgrade a repetitive strength during the earthquake motions. By using the metal material of SS400 general structural rolled steel, the corresponding cost issues of the damping element will be effectively reduced. The analytical of elasto-plastic coil spring damper (CSD) is introduced, and basic mechanical properties evaluated experimentally and analytically. This study has been examined the response control damper using elasto-plastic hysteresis characteristics of metal material. The paper described the design method of elasto-plastic coil spring damper, basic mechanical properties evaluated from loading test, and analytical model of damper are summarized. It was confirmed that the damping force and mechanical characteristics of elasto-plastic coil spring damper are almost satisfied the design specifications.

  3. Magneto-Rheological Damper - An Experimental Study

    OpenAIRE

    Lozoya-Santos , Jorge De-Jesus; Morales-Menéndez , Rubén; Ramirez-Mendoza , Ricardo; Tudon-Martınez , Juan ,; Sename , Olivier; Dugard , Luc

    2012-01-01

    International audience; A Magneto-Rheological (MR) damper is evaluated under exhaustive experimental scenarios, generating a complete database. The obtained database includes classical tests and new proposals emphasizing the frequency contents. It also includes the impact of the electric current fluctuations. The variety of the performed experiments allows to study the MR damper force dynamics. A brief description of the damper behavior and a categorization of experiments based on driving con...

  4. An experimental artificial-neural-network-based modeling of magneto-rheological fluid dampers

    International Nuclear Information System (INIS)

    Tudón-Martínez, J C; Lozoya-Santos, J J; Morales-Menendez, R; Ramirez-Mendoza, R A

    2012-01-01

    A static model for a magneto-rheological (MR) damper based on artificial neural networks (ANNs) is proposed, and an intensive and experimental study is presented for designing the ANN structure. The ANN model does not require time delays in the input vector. Besides the electric current signal, only one additional sensor is used to achieve a reliable MR damper structure. The model is experimentally validated with two commercial MR dampers of different characteristics: MR 1 damper with continuous actuation and MR 2 damper with two levels of actuation. The error to signal ratio (ESR) index is used to measure the model accuracy; for both MR dampers, an average value of 6.03% of total error is obtained from different experiments, which are designed to explore the nonlinearities of the MR phenomenon at different frequencies by including the impact of the electric current fluctuations. The proposed ANN model is compared with other well known parametric models; the qualitative and quantitative comparison among the models highlights the advantages of the ANN for representing a commercial MR damper. The ESR index was reduced by the ANN-based model by up to 29% with respect to the parametric models for the MR 1 damper and up to 40% for the MR 2 damper. The force–velocity diagram is used to compare the modeling properties of each approach: (1) the Bingham model cannot describe the hysteresis of both MR dampers and the distribution function of the modeled force varies from the experimental data, (2) the algebraic models have complications in representing the nonlinear behavior of the asymmetric damper (MR 2 ) and, (3) the ANN-based MR damper can model the nonlinearities of both MR dampers and presents good scalability; the accuracy of the results supports the use of this model for the validation of semi-active suspension control systems for a vehicle, by using nonlinear simulations. (paper)

  5. Energy based optimization of viscous–friction dampers on cables

    International Nuclear Information System (INIS)

    Weber, F; Boston, C

    2010-01-01

    This investigation optimizes numerically a viscous–friction damper connected to a cable close to one cable anchor for fastest reduction of the total mechanical cable energy during a free vibration decay test. The optimization parameters are the viscous coefficient of the viscous part and the ratio between the friction force and displacement amplitude of the friction part of the transverse damper. Results demonstrate that an almost pure friction damper with negligibly small viscous damping generates fastest cable energy reduction over the entire decay. The ratio between the friction force and displacement amplitude of the optimal friction damper differs from that derived from the energy equivalent optimal viscous damper. The reason for this is that the nonlinearity of the friction damper causes energy spillover from the excited to higher modes of the order of 10%, i.e. cables with attached friction dampers vibrate at several frequencies. This explains why the energy equivalent approach does not yield the optimal friction damper. Analysis of the simulation data demonstrates that the optimally tuned friction damper dissipates the same energy per cycle as if each modal component of the cable were damped by its corresponding optimal linear viscous damper

  6. Development of models of the magnetorheological fluid damper

    Energy Technology Data Exchange (ETDEWEB)

    Kazakov, Yu.B., E-mail: elmash@em.ispu.ru; Morozov, N.A.; Nesterov, S.A., E-mail: sergeinesterov37@gmail.com

    2017-06-01

    The algorithm for analytical calculation of a power characteristic of magnetorheological (MR) dampers taking into account the rheological properties of MR fluid is considered. The nonlinear magnetorheological characteristics are represented by piecewise linear approximation to MR fluid areas with different viscosities. The extended calculated power characteristics of a MR damper are received and they coincide with actual results. The finite element model of a MR damper is developed; it allows carrying out the analysis of a MR damper taking into account the mutual influence of electromagnetic, hydrodynamic and thermal fields. The results of finite element simulation coincide with analytical solutions that allows using them for design development of a MR damper. - Highlights: • Division of a MR fluid rheological curve into two sections with different viscosities. • Algorithm for calculation of a power characteristic of MR dampers is proposed. • Finite element model of a MR damper is developed. • Results of finite element simulation coincide with analytical solutions.

  7. Maximizing semi-active vibration isolation utilizing a magnetorheological damper with an inner bypass configuration

    Energy Technology Data Exchange (ETDEWEB)

    Bai, Xian-Xu, E-mail: bai@hfut.edu.cn [Department of Vehicle Engineering, Hefei University of Technology, Hefei 230009 (China); Wereley, Norman M.; Hu, Wei [Department of Aerospace Engineering, University of Maryland, College Park, Maryland 20742 (United States)

    2015-05-07

    A single-degree-of-freedom (SDOF) semi-active vibration control system based on a magnetorheological (MR) damper with an inner bypass is investigated in this paper. The MR damper employing a pair of concentric tubes, between which the key structure, i.e., the inner bypass, is formed and MR fluids are energized, is designed to provide large dynamic range (i.e., ratio of field-on damping force to field-off damping force) and damping force range. The damping force performance of the MR damper is modeled using phenomenological model and verified by the experimental tests. In order to assess its feasibility and capability in vibration control systems, the mathematical model of a SDOF semi-active vibration control system based on the MR damper and skyhook control strategy is established. Using an MTS 244 hydraulic vibration exciter system and a dSPACE DS1103 real-time simulation system, experimental study for the SDOF semi-active vibration control system is also conducted. Simulation results are compared to experimental measurements.

  8. Experimental calibration of the mathematical model of Air Torque Position dampers with non-cascading blades

    Directory of Open Access Journals (Sweden)

    Bikić Siniša M.

    2016-01-01

    Full Text Available This paper is focused on the mathematical model of the Air Torque Position dampers. The mathematical model establishes a link between the velocity of air in front of the damper, position of the damper blade and the moment acting on the blade caused by the air flow. This research aims to experimentally verify the mathematical model for the damper type with non-cascading blades. Four different types of dampers with non-cascading blades were considered: single blade dampers, dampers with two cross-blades, dampers with two parallel blades and dampers with two blades of which one is a fixed blade in the horizontal position. The case of a damper with a straight pipeline positioned in front of and behind the damper was taken in consideration. Calibration and verification of the mathematical model was conducted experimentally. The experiment was conducted on the laboratory facility for testing dampers used for regulation of the air flow rate in heating, ventilation and air conditioning systems. The design and setup of the laboratory facility, as well as construction, adjustment and calibration of the laboratory damper are presented in this paper. The mathematical model was calibrated by using one set of data, while the verification of the mathematical model was conducted by using the second set of data. The mathematical model was successfully validated and it can be used for accurate measurement of the air velocity on dampers with non-cascading blades under different operating conditions. [Projekat Ministarstva nauke Republike Srbije, br. TR31058

  9. Cycle energy control of magnetorheological dampers on cables

    International Nuclear Information System (INIS)

    Weber, F; Feltrin, G; Motavalli, M; Distl, H

    2009-01-01

    The dissipated cycle energy of magnetorheological (MR) dampers operated at constant current results from controllable hysteretic damping and from almost current independent, small viscous damping. Thus, the emulation of Coulomb friction and linear viscous damping necessitates current modulation during one vibration cycle and therefore current drivers. To avoid this drawback, a cycle energy control (CEC) approach is presented which controls the hysteretic MR damper part such that the total MR damper energy equals the energy of optimal linear viscous damping by constant current during one cycle. The excited higher modes due to the hysteretic damping part are partially damped by the MR damper viscous part. Simulations show that CEC copes better with damper force dynamics and constraints than emulated linear viscous damping due to the slow control force dynamics of CEC which are given by cable amplitude dynamics. It is demonstrated that CEC of MR dampers with viscosity of approximately 4.65% of the optimal modal viscosity performs better than optimal linear viscous damping. The reason is that this damper viscosity represents an optimal compromise between maximum energy spillover to higher modes due to the controllable hysteretic part which produces more cable damping and maximum viscous damping of these higher modes. Damping tests on a cable with an MR damper validate the CEC approach

  10. Development of Optimal Viscous Dampers for RC Structures in Near Field Ground Motions

    International Nuclear Information System (INIS)

    Puthanpurayil, Arun M.; Reynolds, Paul

    2008-01-01

    Recent researches show that more than 50% of the economic loss in earthquakes is due to damage of non-structural elements: $8 billion loss in the 1989 Loma Prieta earthquake and $18.5 billion in the 1994 Northridge earthquake. An approach to reduce the economic loss during a seismic event without compromising the structural safety aspect is to incorporate special mechanical devices like fluid viscous dampers in the parent structural system. A recent study carried out to assess the efficacy of viscous dampers in reducing nonstructural damage of low, medium and high rise structures shows that; linear dampers are well suited for low rise category whereas the medium and high rise category requires nonlinear dampers. In this paper an analytical approach is adopted to derive the optimal combination of damper design parameters for all the three categories of structure subjected to near field ground motion. Linear time history analysis by direct time integration was carried out for the linear viscous dampers, while the parameters of the nonlinear viscous dampers were obtained using nonlinear modal time history analysis (Fast Nonlinear analysis). The results of the study are presented in the form of a set of design curves which can be used for the initial selection of parameters for Damper design

  11. Special Fluid Viscous Dampers For The Messina Strait Bridge

    International Nuclear Information System (INIS)

    Colato, Gian Paolo; Infanti, Samuele; Castellano, Maria Gabriella

    2008-01-01

    The Messina Strait Bridge would be the world's longest suspension bridge, with a design earthquake characterised by a PGA value of 0.58 g and a distance between the ipocenter and the bridge of 15 km. Said critical structure of course would need a suitable restraint system for traffic braking loads, wind and seismic actions. Each type of load requires a specific behaviour of the restraint system, making its design a big challenge.The restraint system comprises special types of fluid viscous dampers, installed both in longitudinal and transverse direction, both at the towers and at the anchorages. In seismic conditions they behave as viscous dampers, to reduce the forces on the structural elements and the movements of the bridge deck. But in service dynamic conditions, e.g. under traffic or wind load, the devices shall behave like shock transmission units, thus preventing the longitudinal and transverse movements of the deck.FIP Industriale cooperated with the selected General Contractor, a consortium lead by Impregilo, in the design of said viscous dampers. This paper describes the main features of said devices

  12. Modelling and Control of Magnetorheological Damper

    DEFF Research Database (Denmark)

    Bhowmik, Subrata

    , used as reference case for assessment of the proposed control methods with negative stiffness. Viscous damping with negative stiffness (VDNS) initially illustrates the effectiveness of the negative stiffness component in structural damping. In a linear control setting negative stiffness requires active...... damper is identified by both the standard parametric Bouc-Wen model and the non-parametric neural network model from an experimental data set generated by dynamic tests of the MR damper mounted in a hydraulic testing machine. The forward model represents the direct dynamics of the MR damper where...... are essential input parameters for the MR damper modelling. Thus, for proper training, the quality of the velocity data is very important. However, direct velocity measurement is not easy. From the displacement data or the acceleration data, velocity can be determined by using simple differentiation...

  13. Beam stability in synchrotrons with digital transverse feedback systems in dependence on beam tunes

    International Nuclear Information System (INIS)

    Zhabitskij, V.M.

    2011-01-01

    The beam stability problem in synchrotrons with a digital transverse feedback system (TFS) is studied. The TFS damper kicker (DK) corrects the transverse momentum of a bunch in proportion to its displacement from the closed orbit measured at the location of the beam position monitor (BPM). It is shown that the area and configuration of the beam stability separatrix depend on the beam tune, the feedback gain, the phase balance between the phase advance from BPM to DK and the phase response of the feedback chain at the betatron frequency

  14. Development of aluminium viscous damper by high speed MIG welding process; Kosoku MIG yosetsuho ni yoru aluminium sei viscous damper no kaihatsu

    Energy Technology Data Exchange (ETDEWEB)

    Hino, H; Hotta, M [Nippon Light Metal Co. Ltd., Tokyo (Japan); Maeda, Y; Shimizu, H [Fukoku Co. Ltd., Saitama (Japan)

    1997-10-01

    We have developed a welded aluminum viscous damper to improve the joining strength between the case and the cover of the conventional damper mechanically fastened by adhesion. The distortion of the welded damper was decreased to an acceptable level using the high speed MIG welding process. Sound quality and good appearance were obtained by optimizing the initial speed of the filler wire and by controlling the welding conditions at the starting part and in the lap part. The leakage load and the fatigue limit of the welded damper were 5 and 10 times those of the conventional damper, respectively. 3 refs., 15 figs.

  15. Applications of tuned mass dampers to improve performance of large space mirrors

    Science.gov (United States)

    Yingling, Adam J.; Agrawal, Brij N.

    2014-01-01

    In order for future imaging spacecraft to meet higher resolution imaging capability, it will be necessary to build large space telescopes with primary mirror diameters that range from 10 m to 20 m and do so with nanometer surface accuracy. Due to launch vehicle mass and volume constraints, these mirrors have to be deployable and lightweight, such as segmented mirrors using active optics to correct mirror surfaces with closed loop control. As a part of this work, system identification tests revealed that dynamic disturbances inherent in a laboratory environment are significant enough to degrade the optical performance of the telescope. Research was performed at the Naval Postgraduate School to identify the vibration modes most affecting the optical performance and evaluate different techniques to increase damping of those modes. Based on this work, tuned mass dampers (TMDs) were selected because of their simplicity in implementation and effectiveness in targeting specific modes. The selected damping mechanism was an eddy current damper where the damping and frequency of the damper could be easily changed. System identification of segments was performed to derive TMD specifications. Several configurations of the damper were evaluated, including the number and placement of TMDs, damping constant, and targeted structural modes. The final configuration consisted of two dampers located at the edge of each segment and resulted in 80% reduction in vibrations. The WFE for the system without dampers was 1.5 waves, with one TMD the WFE was 0.9 waves, and with two TMDs the WFE was 0.25 waves. This paper provides details of some of the work done in this area and includes theoretical predictions for optimum damping which were experimentally verified on a large aperture segmented system.

  16. Waveguide harmonic damper for klystron amplifier

    International Nuclear Information System (INIS)

    Kang, Y.

    1998-01-01

    A waveguide harmonic damper was designed for removing the harmonic frequency power from the klystron amplifiers of the APS linac. Straight coaxial probe antennas are used in a rectangular waveguide to form a damper. A linear array of the probe antennas is used on a narrow wall of the rectangular waveguide for damping klystron harmonics while decoupling the fundamental frequency in dominent TE 01 mode. The klystron harmonics can exist in the waveguide as waveguide higher-order modes above cutoff. Computer simulations are made to investigate the waveguide harmonic damping characteristics of the damper

  17. Flow Mode Magnetorheological Dampers with an Eccentric Gap

    Directory of Open Access Journals (Sweden)

    Young-Tai Choi

    2014-07-01

    Full Text Available This paper analyzes flow mode magnetorheological (MR dampers with an eccentric annular gap (i.e., a nonuniform annular gap. To this end, an MR damper analysis for an eccentric annular gap is constructed based on approximating the eccentric annular gap using a rectangular duct with a variable gap, as well as a Bingham-plastic constitutive model of the MR fluid. Performance of flow mode MR dampers with an eccentric gap was assessed analytically using both field-dependent damping force and damping coefficient, which is the ratio of equivalent viscous field-on damping to field-off damping. In addition, damper capabilities of flow mode MR dampers with an eccentric gap were compared to a concentric gap (i.e., uniform annular gap.

  18. The importance of damper drive performance for clean air

    International Nuclear Information System (INIS)

    Wistrom, K.

    2002-01-01

    Amendments to the U.S. Federal Clean Air Act require petroleum refineries and other industries to examine every aspects of their process heating operations in order to reduce cumulative nitrogen oxide emissions from their plants. It has been found that changing the final damper control elements to more reliable and accurate damper drives greatly improves the combustion of air and flue gases and reduces tramp air from entering furnaces. This paper discusses the increasing importance of precise damper drives in nitrogen oxides reduction efforts, and the challenges involved in effecting good damper control. It also provides some technical details about final control drives, manufactured by TYPE K Damper Drives, a division of Controls International Inc., that thrive in environments of extreme temperatures, heavy vibration and fly ash, while providing continuous duty service with smooth, accurate and repeatable damper positioning. Case history of an Ontario oil refinery installing several damper drives designed by TYPE K, indicating high level of nitrogen oxides reduction is described to illustrate the importance and the advantages of damper control drives designed by this firm. In addition to meeting regulatory requirements, additional benefits include improved product quality and safety levels, combined with lower maintenance expenses. photos

  19. Experimental investigation of nonlinear characteristics of a smart fluid damper

    Science.gov (United States)

    Rahman, Mahmudur; Ong, Zhi Chao; Chong, Wen Tong; Julai, Sabariah; Ahamed, Raju

    2018-05-01

    Smart fluids, known as smart material, are used to form controllable dampers in vibration control applications. Magnetorheological(MR) fluid damper is a well-known smart fluid damper which has a reputation to provide high damping force with low-power input. However, the force/velocity of the MR damper is significantly nonlinear and proper characteristic analysis are required to be studied for optimal implementation in structural vibration control. In this study, an experimental investigation is carried out to test the damping characteristics of MR damper. Dynamic testing is performed with a long-stroke MR damper model no RD-80410-1 from Lord corporation on a universal testing machine(UTM). The force responses of MR damper are measured under different stroke lengths, velocities and current inputs and their performances are analyzed. This study will play a key role to implement MR damper in many structural vibration control applications.

  20. A novel test rig to investigate under-platform damper dynamics

    Science.gov (United States)

    Botto, Daniele; Umer, Muhammad

    2018-02-01

    In the field of turbomachinery, vibration amplitude is often reduced by dissipating the kinetic energy of the blades with devices that utilize dry friction. Under-platform dampers, for example, are often placed in the underside of two consecutive turbine blades. Dampers are kept in contact with the under-platform of the respective blades by means of the centrifugal force. If the damper is well designed, vibration of blades instigate a relative motion between the under-platform and the damper. A friction force, that is a non-conservative force, arises in the contact and partly dissipates the vibration energy. Several contact models are available in the literature to simulate the contact between the damper and the under-platform. However, the actual dynamics of the blade-damper interaction have not fully understood yet. Several test rigs have been previously developed to experimentally investigate the performance of under-platform dampers. The majority of these experimental setups aim to evaluate the overall damper efficiency in terms of reduction in response amplitude of the blade for a given exciting force that simulates the aerodynamic loads. Unfortunately, the experimental data acquired on the blade dynamics do not provide enough information to understand the damper dynamics. Therefore, the uncertainty on the damper behavior remains a big issue. In this work, a novel experimental test rig has been developed to extensively investigate the damper dynamic behavior. A single replaceable blade is clamped in the rig with a specific clamping device. With this device the blade root is pressed against a groove machined in the test rig. The pushing force is controllable and measurable, to better simulate the actual centrifugal load acting on the blade. Two dampers, one on each side of the blade, are in contact with the blade under-platforms and with platforms on force measuring supports. These supports have been specifically designed to measure the contact forces on the

  1. Hybrid magnetorheological fluid–elastomeric lag dampers for helicopter stability augmentation

    International Nuclear Information System (INIS)

    Hu Wei; Wereley, Norman M

    2008-01-01

    A laboratory demonstration of a hybrid magnetorheological fluid–elastomeric (MRFE) damper is investigated for adjustable or programmable lag mode damping in helicopters, so that damping requirements can be varied as a function of different flight conditions. The laboratory demonstration of this hybrid MRFE lag damper consists of a double lap shear elastomeric damper in parallel with two magnetorheological (MR) flow mode dampers. This is compared to a damper where only elastomeric materials are implemented, i.e., a double lap shear specimen. The relationship between the output force and the quasi-steady harmonic displacement input to a flow mode MR damper is exploited, where the output force can be adjusted as a function of applied magnetic field. Equivalent viscous damping is used to compare the damping characteristics of the hybrid damper to a conventional elastomeric damper under steady-state sinusoidal displacement excitation. To demonstrate feasibility, a hybrid MRFE damper test setup is designed, and single frequency (lag frequency or rotor in-plane bending frequency) and dual frequency (lag frequency and rotor frequency) tests are conducted under different magnetic fields. The hybrid MRFE damper exhibits amplitude-dependent damping behavior. However, with application of a magnetic field, the damping level is controlled to a specific damping level objective as a function of displacement amplitude. Similarly, under dual frequency conditions, damping degradation at the lag frequency, because of lag motion at the rotor frequency, can also be recovered by increasing magnetic field. A time-domain analysis is developed to study the nonlinear dynamic behavior of the hybrid MRFE damper. Using rate-dependent elasto-slides, the amplitude-dependent behavior of the hybrid MRFE damper is accurately reconstructed using both constant and current-dependent (i.e. controllable) parameters. The analysis is physically motivated and can be applied to the elastomer and MR fluid

  2. Electromagnetic dampers for cryogenic applications

    Science.gov (United States)

    Brown, Gerald V.; Dirusso, Eliseo

    1988-01-01

    Cryogenic turbomachinery of the type used to pump high-pressure liquid hydrogen at -423 F and liquid oxygen at -297 F to the main engines of the Space Shuttle are subjected to lateral rotor vibrations from unbalance forces and transient loads. Conventional dampers which utilize viscous fluids such as lubricating oil cannot be used in turbopumps because the bearing components are filled with either liquid hydrogen or liquid oxygen, which have viscosity comparable to air and, therefore, are not effective in viscous dampers. Electromagentic dampers are currently being explored as a means of providing damping in cryogenic turbopumps because their damping effectiveness increases as temperature decreases and because they are compatible with the liquid hydrogen or liquid oxygen in the turbopumps.

  3. The use of platform dampers to reduce turbine blade vibrations

    Energy Technology Data Exchange (ETDEWEB)

    Jareland, Martin H.

    2001-07-01

    Friction damping is commonly used in jet engines to reduce the vibration level of the blades and thereby increase the reliability of the engine. This thesis deals with a specific type of friction damper denoted platform damper, which is frequently used in turbine stages. A platform damper is a piece of metal located in a cavity underneath two adjacent blade platforms. It is pressed against the platforms by centrifugal force and friction forces arise in the contacts when a relative motion between the platforms occurs. In this thesis, a number of phenomena regarding platform dampers are investigated and discussed. This is performed both experimentally and theoretically. In the simulations, friction interface models valid for both macroslip and microslip are used. Macroslip means that slipping occurs in the whole contact interface and microslip means that slipping occurs in only part of the interface. The latter is most likely in the contacts between the platform damper and the blade platforms due to the high normal force and the small motions. The first paper deals with mistuning of bladed disks due to variations in the properties of the platform dampers and the closely related topic wear of the dampers. This study indicates that damper mistuning can greatly affect the blade vibrations and that damper and blade mistuning constitutes a more severe case than blade mistuning alone. It is also found that wear of the contact areas can lead either to an increase or decrease in the resonance amplitude of the blades in the studied configuration. In the second paper, so-called cottage-roof dampers are studied. Cottage-roof dampers are a type of platform damper with inclined contact surfaces. The inclination leads to a varying normal load, which complicates the analysis. A model including this effect is presented and simulations are performed both in the time and frequency domain. A parametric study is performed with the aim of finding the optimal damper design with respect to

  4. Optimal Control via Integrating the Dynamics of Magnetorheological Dampers and Structures

    Directory of Open Access Journals (Sweden)

    Amir Fayezioghani

    2015-03-01

    Full Text Available Magnetorheological (MR dampers have the advantage of being tuned by low voltages. This has attracted many researchers to develop semi-active control of structures in theory and practice. Most of the control strategies first obtain the desired forces of dampers without taking their dynamics into consideration and then determine the input voltages according to those forces. As a result, these strategies may face situations where the desired forces cannot be produced by the dampers. In this article, by integrating the equations of the dynamics of MR dampers and the structural motion, and solving them in one set, a more concise semi-active optimal control strategy is presented, so as to bypass the aforementioned drawback. Next, a strong database that can be utilized to form a controller for more realistic implementations is produced. As an illustrative example, the optimal voltages of the dampers of a six-storey shear building are obtained under the scaled El-Centro earthquake and used to train a set of integrated analysis-adaptive neuro-fuzzy inference systems (ANFISs as a controller. Results show that the overall performance of the proposed strategy is higher than most of the other conventional methods.

  5. Feasibility Study of the Electromagnetic Damper for Cable Structures Using Real-Time Hybrid Simulation.

    Science.gov (United States)

    Jung, Ho-Yeon; Kim, In-Ho; Jung, Hyung-Jo

    2017-10-31

    Cable structure is a major component of long-span bridges, such as cable-stayed and suspension bridges, and it transfers the main loads of bridges to the pylons. As these cable structures are exposed to continuous external loads, such as vehicle and wind loads, vibration control and continuous monitoring of the cable are required. In this study, an electromagnetic (EM) damper was designed and fabricated for vibration control and monitoring of the cable structure. EM dampers, also called regenerative dampers, consist of permanent magnets and coils. The electromagnetic force due to the relative motion between the coil and the permanent magnet can be used to control the vibration of the structure. The electrical energy can be used as a power source for the monitoring system. The effects of the design parameters of the damper were numerically analyzed and the damper was fabricated. The characteristics of the damper were analyzed with various external load changes. Finally, the vibration-control and energy-harvesting performances of the cable structure were evaluated through a hybrid simulation. The vibration-control and energy-harvesting performances for various loads were analyzed and the applicability to the cable structure of the EM damper was evaluated.

  6. Vibration control of a cable-stayed bridge using electromagnetic induction based sensor integrated MR dampers

    International Nuclear Information System (INIS)

    Cho, Sang Won; Koo, Jeong Hoi; Jo, Ji Seong

    2007-01-01

    This paper presents a novel electromagnetic induction (EMI) system integrated in magneto rheological (MR) dampers: The added EMI system converts reciprocal motions of MR damper into electiral energy (electromotive force or emf) according to the Faraday's law of electromagnetic induction. Maximum energy dissipation algorithm (MEDA) is employed to regulate the MR dampers because it strives to simplify a complex design process by employing the Lyapunov's direct approach. The emf signal, produced from the EMI, provides the necessary measurement information (i.e., realtive velocity across the damper) for the MEDA controller. Thus, the EMI acts as a sensor in the proposed MR-EMI system. In order to evaluate the performance and robustness of the MR-EMI sensor system with the MEDA control, this study performed an extensive simulation study using the first generation benchmark cable-stayed bridge. Moreover, it compared the performance and the robustness of proposed system with those of Clipped-Optimal Control (COC) and Sliding Mode Control (SMC), which were previously studied for the benchmark cable-stayed bridge. The results show that the MR-EMI system reduced the vibrations of the bridge structure more than those of COC and SMC and show more robust performance than that of SMC. These results suggest that EMIs can be used cost-effective sensing devices for MR damper control systems without compromising the performance of them

  7. Semi-active friction damper for buildings subject to seismic excitation

    Science.gov (United States)

    Mantilla, Juan S.; Solarte, Alexander; Gomez, Daniel; Marulanda, Johannio; Thomson, Peter

    2016-04-01

    Structural control systems are considered an effective alternative for reducing vibrations in civil structures and are classified according to their energy supply requirement: passive, semi-active, active and hybrid. Commonly used structural control systems in buildings are passive friction dampers, which add energy dissipation through damping mechanisms induced by sliding friction between their surfaces. Semi-Active Variable Friction Dampers (SAVFD) allow the optimum efficiency range of friction dampers to be enhanced by controlling the clamping force in real time. This paper describes the development and performance evaluation of a low-cost SAVFD for the reduction of vibrations of structures subject to earthquakes. The SAVFD and a benchmark structural control test structure were experimentally characterized and analytical models were developed and updated based on the dynamic characterization. Decentralized control algorithms were implemented and tested on a shaking table. Relative displacements and accelerations of the structure controlled with the SAVFD were 80% less than those of the uncontrolled structure

  8. Design, Analysis, and Experimental Evaluation of a Double Coil Magnetorheological Fluid Damper

    Directory of Open Access Journals (Sweden)

    Guoliang Hu

    2016-01-01

    Full Text Available A magnetorheological (MR damper is one of the most advanced devices used in a semiactive control system to mitigate unwanted vibration because the damping force can be controlled by changing the viscosity of the internal magnetorheological (MR fluids. This study proposes a typical double coil MR damper where the damping force and dynamic range were derived from a quasistatic model based on the Bingham model of MR fluid. A finite element model was built to study the performance of this double coil MR damper by investigating seven different piston configurations, including the numbers and shapes of their chamfered ends. The objective function of an optimization problem was proposed and then an optimization procedure was constructed using the ANSYS parametric design language (APDL to obtain the optimal damping performance of a double coil MR damper. Furthermore, experimental tests were also carried out, and the effects of the same direction and reverse direction of the currents on the damping forces were also analyzed. The relevant results of this analysis can easily be extended to the design of other types of MR dampers.

  9. Improvements for rotary viscous dampers used in spacecraft deployment mechanisms

    Science.gov (United States)

    Stewart, Alphonso; Powers, Charles; Lyons, Ron

    1998-01-01

    During component level thermal-vacuum deployment testing of eight rotary viscous dampers for the Tropical Rainfall Measuring Mission (TRMM) satellite, all the dampers failed to provide damping during a region of the deployment. Radiographic examination showed that air in the damping fluid caused the undamped motion when the dampers were operated in a vacuum environment. Improvements in the procedure used to fill the dampers with damping fluid, the installation of a Viton vacuum seal in the damper cover, and improved screening techniques eliminated the problem.

  10. Kinetic analysis of elastomeric lag damper for helicopter rotors

    Science.gov (United States)

    Liu, Yafang; Wang, Jidong; Tong, Yan

    2018-02-01

    The elastomeric lag dampers suppress the ground resonance and air resonance that play a significant role in the stability of the helicopter. In this paper, elastomeric lag damper which is made from silicone rubber is built. And a series of experiments are conducted on this elastomeric lag damper. The stress-strain curves of elastomeric lag dampers employed shear forces at different frequency are obtained. And a finite element model is established based on Burgers model. The result of simulation and tests shows that the simple, linear model will yield good predictions of damper energy dissipation and it is adequate for predicting the stress-strain hysteresis loop within the operating frequency and a small-amplitude oscillation.

  11. Design and development of the Macpherson Proton Preve Magneto rheological damper with PID controller

    Science.gov (United States)

    Amiruddin, I. M.; Pauziah, M.; Aminudin, A.; Unuh, M. H.

    2017-10-01

    Since the creation of the first petrol-fuelled vehicle by Karl Benz in the late nineteenth century, car industry has grown considerably to meet the industrial demands. Luxurious looks and agreeable rides are the primary needs of drivers. The Magneto-rheological damper balanced their damping trademark progressively by applying the damping coefficient depending on the control system. In this research, the control calculations are assessed by utilizing the MR damper. The capacity and reliably of the target force for the damper speed is investigated from control algorithm. This is imperative to defeat the damper limitation. In this study, the simulation results of the semi-dynamic MR damper with the PID controller shows better performance in sprung mass acceleration, unsprung mass acceleration and suspension dislodging with permitting over the top tyre acceleration. The altered model of the MR damper is specially designed for Proton Preve specifications and semi-active PID control. The procedure for the advancement incorporates the numerical model to graphically recreate and break down the dynamic framework by utilizing Matlab.

  12. Enhanced damping for bridge cables using a self-sensing MR damper

    Science.gov (United States)

    Chen, Z. H.; Lam, K. H.; Ni, Y. Q.

    2016-08-01

    This paper investigates enhanced damping for protecting bridge stay cables from excessive vibration using a newly developed self-sensing magnetorheological (MR) damper. The semi-active control strategy for effectively operating the self-sensing MR damper is formulated based on the linear-quadratic-Gaussian (LQG) control by further considering a collocated control configuration, limited measurements and nonlinear damper dynamics. Due to its attractive feature of sensing-while-damping, the self-sensing MR damper facilitates the collocated control. On the other hand, only the sensor measurements from the self-sensing device are employed in the feedback control. The nonlinear dynamics of the self-sensing MR damper, represented by a validated Bayesian NARX network technique, are further accommodated in the control formulation to compensate for its nonlinearities. Numerical and experimental investigations are conducted on stay cables equipped with the self-sensing MR damper operated in passive and semi-active control modes. The results verify that the collocated self-sensing MR damper facilitates smart damping for inclined cables employing energy-dissipative LQG control with only force and displacement measurements at the damper. It is also demonstrated that the synthesis of nonlinear damper dynamics in the LQG control enhances damping force tracking efficiently, explores the features of the self-sensing MR damper, and achieves better control performance over the passive MR damping control and the Heaviside step function-based LQG control that ignores the damper dynamics.

  13. Feasibility Study of the Electromagnetic Damper for Cable Structures Using Real-Time Hybrid Simulation

    Directory of Open Access Journals (Sweden)

    Ho-Yeon Jung

    2017-10-01

    Full Text Available Cable structure is a major component of long-span bridges, such as cable-stayed and suspension bridges, and it transfers the main loads of bridges to the pylons. As these cable structures are exposed to continuous external loads, such as vehicle and wind loads, vibration control and continuous monitoring of the cable are required. In this study, an electromagnetic (EM damper was designed and fabricated for vibration control and monitoring of the cable structure. EM dampers, also called regenerative dampers, consist of permanent magnets and coils. The electromagnetic force due to the relative motion between the coil and the permanent magnet can be used to control the vibration of the structure. The electrical energy can be used as a power source for the monitoring system. The effects of the design parameters of the damper were numerically analyzed and the damper was fabricated. The characteristics of the damper were analyzed with various external load changes. Finally, the vibration-control and energy-harvesting performances of the cable structure were evaluated through a hybrid simulation. The vibration-control and energy-harvesting performances for various loads were analyzed and the applicability to the cable structure of the EM damper was evaluated.

  14. Performance of a New Fine Particle Impact Damper

    Directory of Open Access Journals (Sweden)

    Yanchen Du

    2008-01-01

    Full Text Available The energy dissipation mechanisms of conventional impact damper (CID are mainly momentum exchange and friction. During the impact process, a lot of vibration energy cannot be exhausted but reverberated among the vibration partners. Besides, the CID may produce the additional vibration to the system or even amplify the response in the low-frequency vibration. To overcome these shortcomings, this paper proposes a new fine particle impact damper (FPID which for the first time introduces the fine particle plastic deformation as an irreversible energy sink. Then, the experiments of the cantilevered beam with the CID and that with the FPID are, respectively, carried out to investigate the behavior of FPID. The experimental results indicate that the FPID has a better performance in vibration damping than in the CID and the FPID works well in control of the vibration with frequency lower than 50 Hz, which is absent to the non-obstructive particle damper. Thus, the FPID has a bright and significant application future because most of the mechanical vibration falls in the range of low freqency.

  15. Damping of resistive instability in UNK-1 with digital electronics in feedback

    International Nuclear Information System (INIS)

    Zhabitskij, V.M.; Ivanov, I.N.; Korenev, I.L.; Yudin, L.A.

    1991-01-01

    The basis of resistive instability damper system for the UNK-1 is obtained. The system for each of two directions of beam transverse oscillations includes two pairs of pick-up electrodes and damping kickers connected by delayed negative feedback with digital electronics. The requirements for digital electronics in feedback are discussed. The influence of a notch filter is under consideration. In turns out that a 0.8 MHz feedback system damps the resistive instability in the UNK-1 with increment of 0.7 revolution frequency (for low frequencies). 7 refs.; 8 figs

  16. Damping-tunable energy-harvesting vehicle damper with multiple controlled generators: Design, modeling and experiments

    Science.gov (United States)

    Xie, Longhan; Li, Jiehong; Li, Xiaodong; Huang, Ledeng; Cai, Siqi

    2018-01-01

    Hydraulic dampers are used to decrease the vibration of a vehicle, where vibration energy is dissipated as heat. In addition to resulting in energy waste, the damping coefficient in hydraulic dampers cannot be changed during operation. In this paper, an energy-harvesting vehicle damper was proposed to replace traditional hydraulic dampers. The goal is not only to recover kinetic energy from suspension vibration but also to change the damping coefficient during operation according to road conditions. The energy-harvesting damper consists of multiple generators that are independently controlled by switches. One of these generators connects to a tunable resistor for fine tuning the damping coefficient, while the other generators are connected to a control and rectifying circuit, each of which both regenerates electricity and provides a constant damping coefficient. A mathematical model was built to investigate the performance of the energy-harvesting damper. By controlling the number of switched-on generators and adjusting the value of the external tunable resistor, the damping can be fine tuned according to the requirement. In addition to the capability of damping tuning, the multiple controlled generators can output a significant amount of electricity. A prototype was built to test the energy-harvesting damper design. Experiments on an MTS testing system were conducted, with results that validated the theoretical analysis. Experiments show that changing the number of switched-on generators can obviously tune the damping coefficient of the damper and simultaneously produce considerable electricity.

  17. Dissipativity analysis of the base isolated benchmark structure with magnetorheological fluid dampers

    International Nuclear Information System (INIS)

    Erkus, Baris; Johnson, Erik A

    2011-01-01

    This paper investigates the dissipativity and performance characteristics of the semiactive control of the base isolated benchmark structure with magnetorheological (MR) fluid dampers. Previously, the authors introduced the concepts of dissipativity and dissipativity indices in the semiactive control of structures with smart dampers and studied the dissipativity characteristics of simple structures with idealized dampers. To investigate the effects of semiactive controller dissipativity characteristics on the overall performance of the base isolated benchmark building, a clipped optimal control strategy with a linear quadratic Gaussian (LQG) controller and a 20 ton MR fluid damper model is used. A cumulative index is proposed for quantifying the overall dissipativity of a control system with multiple control devices. Two control designs with different dissipativity and performance characteristics are considered as the primary controller in clipped optimal control. Numerical simulations reveal that the dissipativity indices can be classified into two groups that exhibit distinct patterns. It is shown that the dissipativity indices identify primary controllers that are more suitable for application with MR dampers and provide useful information in the semiactive design process that complements other performance indices. The computational efficiency of the proposed dissipativity indices is verified by comparing computation times

  18. Vibration of a string against multiple spring-mass-damper stoppers

    Science.gov (United States)

    Shin, Ji-Hwan; Talib, Ezdiani; Kwak, Moon K.

    2018-02-01

    When a building sways due to strong wind or an earthquake, the elevator rope can undergo resonance, resulting in collision with the hoist-way wall. In this study, a hard stopper and a soft stopper comprised of a spring-mass-damper system installed along the hoist-way wall were considered to prevent the string from undergoing excessive vibrations. The collision of the string with multiple hard stoppers and multiple spring-mass-damper stoppers was investigated using an analytical method. The result revealed new formulas and computational algorithms that are suitable for simulating the vibration of the string against multiple stoppers. The numerical results show that the spring-mass-damper stopper is more effective in suppressing the vibrations of the string and reducing structural failure. The proposed algorithms were shown to be efficient to simulate the motion of the string against a vibration stopper.

  19. Semiactive balancing control scheme in a rotor - bearing system supported on Mr. Dampers: design and experiments

    Energy Technology Data Exchange (ETDEWEB)

    Silva Navarro, Gerardo; Cabrera Amado, Alvaro [Cinvestav, IPN, Mexico, D.F. (Mexico)

    2007-11-15

    This paper deals with the problem of semiactive balancing control of a rotor-bearing system, where one journal bearings is supported on two radial Magneto-Rheological (MR) dampers. The mathematical model of the rotor-bearing system results from an orthotropic Jeffcott-like model and the dynamics associated to the MR dampers, whose rheological properties depend on the current inputs. For control purposes we use the Choi-Lee-Park polynomial for the MR dampers, which is quite consistent with the tpical nonlinear and complex hysteresis behavior and also simplifies the physical implementation on an experimental setup. The semiactive control scheme for the unbalance reponse of the rotor-bearing system is synthesized using sliding-mode control techniques. Some numerical and experimental results are included to illustrate the dynamic performance and robustness of the overall system. [Spanish] En este trabajo se abora el problema de control semiactivo del desbalance en un sistema rotor-chumacera, donde una de las chumaceras convencionales se monta sobre una suspension con dos amortiguadores Magneto-Reologicos (MR) radiales. El modelo matematico del sistema rotorchumacera se obtiene de un modelo tipo Jefcott ortotropico y la dinamica de los amortiguadores MR, cuyas propiedades reologicas dependen de las corrientes electricas de alimentacion. Para propositos de control se emplea el modelo polinomial de Choi-Lee-Park para los dos amortiguadores MR, el cual es consistente con el tipico comportamiento no-lineal y de histeresis, permitiendo simplificar su implementacion fisica en una plataforma experimental. El esquema de control semiactivo de la respuesta al desbalance, en el sistema rotor-chumacera, se basa en las tecnicas de control por modos deslizantes. Se presentan algunos resultados de simulacion numerica y experimentos que utilizan el funcionamiento y robustez del sistema completo.

  20. Vibration isolation using nonlinear damping implemented by a feedback-controlled MR damper

    International Nuclear Information System (INIS)

    Ho, C; Lang, Z Q; Billings, S A; Sapiński, B

    2013-01-01

    The main problem of using a conventional linear damper on a vibration isolation system is that the reduction of the resonant peak in many cases inevitably results in the degradation of the high-frequency transmissibility. Instead of using active control methods which normally depend on the model of the controlled plant and where unmodelled dynamics may induce stability concerns, recent studies have revealed that optimal vibration isolation over a wide frequency range can be achieved by using nonlinear damping. The present study is concerned with the realization of the ideal nonlinear damping characteristic using a feedback-controlled MR damper. Both simulation and experimental studies are conducted to demonstrate the advantages of the simple but effective vibration control strategy. This research work has significant implications for the effective use of MR dampers in the vibration control of a wide range of engineering systems. (paper)

  1. Neuro-fuzzy control strategy for an offshore steel jacket platform subjected to wave-induced forces using magneto rheological dampers

    International Nuclear Information System (INIS)

    Sarrafan, Atabak; Zareh, Seiyed Hamid; Khayyat, Amir Ali Akbar; Zabihollah, Abolghassem

    2012-01-01

    Magnetorheological (MR) damper is a prominent semi-active control device to vibrate mitigation of structures. Due to the inherent non-linear nature of MR damper, an intelligent non-linear neuro-fuzzy control strategy is designed to control wave-induced vibration of an offshore steel jacket platform equipped with MR dampers. In the proposed control system, a dynamic-feedback neural network is adapted to model non-linear dynamic system, and the fuzzy logic controller is used to determine the control forces of MR dampers. By use of two feed forward neural networks required voltages and actual MR damper forces are obtained, in which the first neural network and the second one acts as the inverse dynamics model, and the forward dynamics model of the MR dampers, respectively. The most important characteristic of the proposed intelligent control strategy is its inherent robustness and its ability to handle the non-linear behavior of the system. Besides, no mathematical model needed to calculate forces produced by MR dampers. According to linearized Morison equation, wave-induced forces are determined. The performance of the proposed neuro-fuzzy control system is compared with that of a traditional semi-active control strategy, i.e., clipped optimal control system with LQG-target controller, through computer simulations, while the uncontrolled system response is used as the baseline. It is demonstrated that the design of proposed control system framework is more effective than that of the clipped optimal control scheme with LQG-target controller to reduce the vibration of offshore structure. Furthermore, the control strategy is very important for semi-active control

  2. A Novel Double-Piston Magnetorheological Damper for Space Truss Structures Vibration Suppression

    OpenAIRE

    Qiang Wang; Mehdi Ahmadian; Zhaobo Chen

    2014-01-01

    The design, fabrication, and testing of a new double-piston MR damper for space applications are discussed. The design concept for the damper is described in detail. The electromagnetic analysis of the design and the fabrication of the MR damper are also presented. The design analysis shows that the damper meets the weight and size requirements for being included in a space truss structure. The prototype design is tested in a damper dynamometer. The test results show that the damper can provi...

  3. The investigation about embodiment of vertical isolation structure. An embodiment of the structural plan of damper element

    International Nuclear Information System (INIS)

    Somaki, Takahiro; Miyamoto, Akinori; Nakatogawa, Tetsundo

    2003-01-01

    In order to realize the concept of a vertical isolation system (common deck system), research and development on the vertical isolation structure is now underway. In its first step, structure plans of each of the isolation element and the damper element will be drawn up, and in the next step, tests on these elements will be planed, executed, analyzed, and evaluated, to be reflected to the structure plan. In this report, the structure plan and test plan of damper element is reported. At first, it was concluded in the previous work that the steel-materials damper which can be evaluated by Ramberg-Osgood type is applicable to the vertical isolation system required performance. Then, based on this results, the form range of a damper which satisfies was surveyed from both cross section thickness and distribution of strain by analysis. Next, in order to check the performance (limit a damping capability, load carrying capacity, fatigue strength, and deformability) of an actual damper element based on this analysis result, the test plan for actual scale model was drawn up. (author)

  4. Simulation and experiemntal study on damper by accumulator

    International Nuclear Information System (INIS)

    Wang Xiaobin; Zhou Yong; Chen Wuxing; Hu Junhua

    2010-01-01

    In order to prevent stressing penstocks broken by earthquake or other shock waves, dampers are used widely in nuclear power plant or pipelines transporting radioactive material. A new-style damper by accumulator is introduced. Inside the damper an accumulator is installed, the outward corrugated tubes are added outside the piston rod. So it has advantages of small volume, no oil leakage. The simulation and experimental research show that if the clearance between the piston and cylinder, the spring stiffness of accumulator or the throttle valve size is varied, the dynamic performance of the impact displacement, resistance in low velocity and lock-up velocity of dampe would be influenced. The support of nuclear classified pipelines can be satisfied by using this new-style accumulator damper. (authors)

  5. BNL 56 MHz HOM Damper Prototype Fabrication at JLab

    Energy Technology Data Exchange (ETDEWEB)

    Huque, Naeem A. [Jefferson Lab., Newport News, VA (United States); Daly, Edward F. [Jefferson Lab., Newport News, VA (United States); Clemens, William A. [Jefferson Lab., Newport News, VA (United States); McIntyre, Gary T. [Brookhaven National Lab. (BNL), Upton, NY (United States); Wu, Qiong [Brookhaven National Lab. (BNL), Upton, NY (United States); Seberg, Scott [Brookhaven National Lab. (BNL), Upton, NY (United States); Bellavia, Steve [Brookhaven National Lab. (BNL), Upton, NY (United States)

    2015-09-01

    A prototype Higher-Order Mode (HOM) Damper was fabricated at JLab for the Relativistic Heavy-Ion Collider's (RHIC) 56 MHz cavity at Brookhaven National Laboratory (BNL). Primarily constructed from high RRR Niobium and Sapphire, the coaxial damper presented significant challenges in electron-beam welding (EBW), brazing and machining via acid etching. The results of the prototype operation brought about changes in the damper design, due to overheating braze alloys and possible multi-pacting. Five production HOM dampers are currently being fabricated at JLab. This paper outlines the challenges faced in the fabrication process, and the solutions put in place.

  6. A design strategy for magnetorheological dampers using porous valves

    International Nuclear Information System (INIS)

    Hu, W; Robinson, R; Wereley, N M

    2009-01-01

    To design a porous-valve-based magnetorheological (MR) damper, essential design parameters are presented. The key elements affecting the damper performance are identified using flow analysis in porous media and an empirical magnetic field distribution in the porous valve. Based on a known MR fluid, the relationship between the controllable force of the damper and the porous valve characteristics, i.e. porosity and tortuosity, is developed. The effect of the porosity and tortuosity on the field-off damping force is exploited by using semi-empirical flow analysis. The critical flow rate for the onset of nonlinear viscous damping force is determined. Using the above design elements, an MR damper using by-pass porous valve is designed and tested. The experimental damper force and equivalent damping are compared with the predicted results to validate this design strategy.

  7. A design strategy for magnetorheological dampers using porous valves

    Energy Technology Data Exchange (ETDEWEB)

    Hu, W; Robinson, R; Wereley, N M [Smart Structures Laboratory, Alfred Gessow Rotorcraft Center, Department of Aerospace Engineering, University of Maryland, College Park, MD 20742 (United States)], E-mail: wereley@umd.edu

    2009-02-01

    To design a porous-valve-based magnetorheological (MR) damper, essential design parameters are presented. The key elements affecting the damper performance are identified using flow analysis in porous media and an empirical magnetic field distribution in the porous valve. Based on a known MR fluid, the relationship between the controllable force of the damper and the porous valve characteristics, i.e. porosity and tortuosity, is developed. The effect of the porosity and tortuosity on the field-off damping force is exploited by using semi-empirical flow analysis. The critical flow rate for the onset of nonlinear viscous damping force is determined. Using the above design elements, an MR damper using by-pass porous valve is designed and tested. The experimental damper force and equivalent damping are compared with the predicted results to validate this design strategy.

  8. A new adaptive hybrid electromagnetic damper: modelling, optimization, and experiment

    International Nuclear Information System (INIS)

    Asadi, Ehsan; Ribeiro, Roberto; Behrad Khamesee, Mir; Khajepour, Amir

    2015-01-01

    This paper presents the development of a new electromagnetic hybrid damper which provides regenerative adaptive damping force for various applications. Recently, the introduction of electromagnetic technologies to the damping systems has provided researchers with new opportunities for the realization of adaptive semi-active damping systems with the added benefit of energy recovery. In this research, a hybrid electromagnetic damper is proposed. The hybrid damper is configured to operate with viscous and electromagnetic subsystems. The viscous medium provides a bias and fail-safe damping force while the electromagnetic component adds adaptability and the capacity for regeneration to the hybrid design. The electromagnetic component is modeled and analyzed using analytical (lumped equivalent magnetic circuit) and electromagnetic finite element method (FEM) (COMSOL ® software package) approaches. By implementing both modeling approaches, an optimization for the geometric aspects of the electromagnetic subsystem is obtained. Based on the proposed electromagnetic hybrid damping concept and the preliminary optimization solution, a prototype is designed and fabricated. A good agreement is observed between the experimental and FEM results for the magnetic field distribution and electromagnetic damping forces. These results validate the accuracy of the modeling approach and the preliminary optimization solution. An analytical model is also presented for viscous damping force, and is compared with experimental results The results show that the damper is able to produce damping coefficients of 1300 and 0–238 N s m −1 through the viscous and electromagnetic components, respectively. (paper)

  9. Study on the development of passive MR damper with displacement-dependent damping characteristics

    International Nuclear Information System (INIS)

    Murakami, Takahiro; Sakai, Michiya; Nakano, Masami

    2010-01-01

    In this paper, we propose a new concept of a magneto-rheological (MR) fluid damper, which is a passive MR fluid damper. The passive MR damper has no electrical devices, such as a sensor, power supply and controller, and hence, it has an advantage in reliability and cost compared with semi-active MR dampers. Moreover, the proposed MR damper can be designed to have a variable damping force in response to its displacement. In this paper, the dynamic performance of the passive MR damper is experimentally demonstrated. The prototype of the proposed damper has been manufactured in order to verify the dynamic performance. The displacement excitation test result of the damper demonstrates that the damping characteristics depend on its displacement amplitude, that is, the damper behaves as a linear viscous damper under small vibrations and develops much higher damping performance under large vibrations. (author)

  10. An Experimental Study on Steel and Teflon Squeeze Film Dampers

    Directory of Open Access Journals (Sweden)

    Asad A. Khalid

    2006-01-01

    Full Text Available In this paper, the vibration analysis on Teflon and steel squeeze film dampers has been carried out. At different frequency ranges, vibration amplitude and the resonance frequency are measured. The eccentricity ratio at resonance speed has been determined. Results show that the vibration amplitude of the steel damper is 10% less at resonance compared with the Teflon damper. On the other hand, saving weight of 36% has been achieved by using the Teflon damper.

  11. An enhanced nonlinear damping approach accounting for system constraints in active mass dampers

    Science.gov (United States)

    Venanzi, Ilaria; Ierimonti, Laura; Ubertini, Filippo

    2015-11-01

    Active mass dampers are a viable solution for mitigating wind-induced vibrations in high-rise buildings and improve occupants' comfort. Such devices suffer particularly when they reach force saturation of the actuators and maximum extension of their stroke, which may occur in case of severe loading conditions (e.g. wind gust and earthquake). Exceeding actuators' physical limits can impair the control performance of the system or even lead to devices damage, with consequent need for repair or substitution of part of the control system. Controllers for active mass dampers should account for their technological limits. Prior work of the authors was devoted to stroke issues and led to the definition of a nonlinear damping approach, very easy to implement in practice. It consisted of a modified skyhook algorithm complemented with a nonlinear braking force to reverse the direction of the mass before reaching the stroke limit. This paper presents an enhanced version of this approach, also accounting for force saturation of the actuator and keeping the simplicity of implementation. This is achieved by modulating the control force by a nonlinear smooth function depending on the ratio between actuator's force and saturation limit. Results of a numerical investigation show that the proposed approach provides similar results to the method of the State Dependent Riccati Equation, a well-established technique for designing optimal controllers for constrained systems, yet very difficult to apply in practice.

  12. Coaxial higher-order mode damper employing a high-pass filter

    International Nuclear Information System (INIS)

    Kang, Y.W.; Jiang, X.

    1997-01-01

    Two different types of coaxial higher-order mode (HOM) dampers have been investigated for the Advanced Photon Source (APS) storage ring cavities: e-probe dampers and h-loop dampers. Realization of the h-loop dampers has been difficult because the loop antenna couples not only to the HOMs but also to the accelerating mode and results in loss of Q at the fundamental frequency. Previously, a first-order fundamental rejection filter was tested with unsatisfactory rejection characteristics. This problem can be overcome by using a higher-order high-pass filter between the loop and the matched load. Prototype dampers have been fabricated and tested in a storage ring single-cell cavity and the damping characteristic was analyzed

  13. A Series Active Damper with Closed-loop Control for Stabilizing Single-phase Power-Electronics-Based Power System

    DEFF Research Database (Denmark)

    Lu, Dapeng; Wang, Xiongfei; Bai, Haofeng

    2016-01-01

    resistance through detection and resonant controller, the series active damper can suppress the resonance with its external damping character in closed-loop damping character are carried out. Simulation and experimental results are presented to verify the effectiveness of the proposed series active damper....

  14. Flow Mode Magnetorheological Dampers with an Eccentric Gap

    OpenAIRE

    Young-Tai Choi; Norman M. Wereley

    2014-01-01

    This paper analyzes flow mode magnetorheological (MR) dampers with an eccentric annular gap (i.e., a nonuniform annular gap). To this end, an MR damper analysis for an eccentric annular gap is constructed based on approximating the eccentric annular gap using a rectangular duct with a variable gap, as well as a Bingham-plastic constitutive model of the MR fluid. Performance of flow mode MR dampers with an eccentric gap was assessed analytically using both field-dependent damping force and dam...

  15. The Development of A Squeeze Film Damper Parametric Model in the Context of a Fluid-structural Interaction Task

    Science.gov (United States)

    Novikov, Dmitrii K.; Diligenskii, Dmitrii S.

    2018-01-01

    The article considers the work of some squeeze film damper with elastic rings parts. This type of damper is widely used in gas turbine engines supports. Nevertheless, modern analytical solutions have a number of limitations. The article considers the behavior of simple hydrodynamic damping systems. It describes the analysis of fluid-solid interaction simulation applicability for the defying properties of hydrodynamic damper with elastic rings (“allison ring”). There are some recommendations on the fluid structural interaction analysis of the hydrodynamic damper with elastic rings.

  16. A Novel Double-Piston Magnetorheological Damper for Space Truss Structures Vibration Suppression

    Directory of Open Access Journals (Sweden)

    Qiang Wang

    2014-01-01

    Full Text Available The design, fabrication, and testing of a new double-piston MR damper for space applications are discussed. The design concept for the damper is described in detail. The electromagnetic analysis of the design and the fabrication of the MR damper are also presented. The design analysis shows that the damper meets the weight and size requirements for being included in a space truss structure. The prototype design is tested in a damper dynamometer. The test results show that the damper can provide nearly 80 N of damping force at its maximum velocity and current. The test results also show that the seal drag could contribute significantly to the damping forces. Additionally, the test results indicate that both the work by the damper and damping force increase rapidly with increasing current at lower currents and taper off at higher currents as the damper starts to saturate. The damper force versus velocity plots show hysteresis in both pre- and postyield regions and asymmetric forces in jounce and rebound. A model is proposed for representing the force-displacement, force-velocity, and asymmetric forces observed in test results. A comparison of the modeling results and test data indicates that the model accurately represents the force characteristics of the damper.

  17. A minimax stochastic optimal semi-active control strategy for uncertain quasi-integrable Hamiltonian systems using magneto-rheological dampers

    DEFF Research Database (Denmark)

    Feng, Ju; Ying, Zu-Guang; Zhu, Wei-Qiu

    2012-01-01

    A minimax stochastic optimal semi-active control strategy for stochastically excited quasi-integrable Hamiltonian systems with parametric uncertainty by using magneto-rheological (MR) dampers is proposed. Firstly, the control problem is formulated as an n-degree-of-freedom (DOF) controlled, uncer...

  18. Neural networkbased semi-active control strategy for structural vibration mitigation with magnetorheological damper

    DEFF Research Database (Denmark)

    Bhowmik, Subrata

    2011-01-01

    This paper presents a neural network based semi-active control method for a rotary type magnetorheological (MR) damper. The characteristics of the MR damper are described by the classic Bouc-Wen model, and the performance of the proposed control method is evaluated in terms of a base exited shear...... to determine the damper current based on the derived optimal damper force. For that reason an inverse MR damper model is also designed based on the neural network identification of the particular rotary MR damper. The performance of the proposed controller is compared to that of an optimal pure viscous damper...

  19. Damper modules with adapted stiffness ratio

    Energy Technology Data Exchange (ETDEWEB)

    Sonnenburg, R.; Stretz, A. [ZF Sachs AG, Entwicklungszentrum, Schweinfurt (Germany)

    2011-07-15

    A mechanism for the excitation of piston rod vibrations in automotive damper modules is discussed by a simple model. An improved nonlinear model based on elasticity effects leads to good simulation results. It is shown theoretically and experimentally that the adaptation of the stiffness of the piston rod bushing to the ''stiffness'' of the damper force characteristic can eliminate the piston rod oscillations completely. (orig.)

  20. Broadband Liquid Dampers to Stabilize Flexible Spacecraft Structures

    NARCIS (Netherlands)

    Kuiper, J.M.

    2012-01-01

    Mass-spring and liquid dampers enable structural vibration control to attenuate single, coupled lateral and torsional vibrations in diverse structures. Out of these, the passively tuned liquid damper (TLD) class is wanted due to its broad applicability, extreme reliability, robustness, long life

  1. Edgewise vibration control of wind turbine blades using roller and liquid dampers

    International Nuclear Information System (INIS)

    Zhang, Z L; Nielsen, S R K

    2014-01-01

    This paper deals with the passive vibration control of edgewise vibrations by means of roller dampers and tuned liquid column dampers (TLCDs). For a rotating blade, the large centrifugal acceleration makes it possible to use roller dampers or TLCDs with rather small masses for effectively suppressing edgewise vibrations. The roller dampers are more volumetrically efficient due to the higher mass density of the steel comparing with the liquid. On the other hand, TLCDs have their advantage that it is easier to specify the optimum damping of the damper by changing the opening ratio of the orifice. In this paper, 2-DOF nonlinear models are suggested for tuning a roller damper or a TLCD attached to a rotating wind turbine blade, ignoring the coupling between the blade and the tower. The decoupled optimization is verified by incorporating the optimized damper into a more sophisticated 13- DOF wind turbine model with due consideration of the coupled blade-tower-drivetrain vibrations, quasi-static aeroelasticity as well as a collective pitch controller. Performances of the dampers are compared in terms of the control efficiency and the practical applications. The results indicate that roller dampers and TLCDs at optimal tuning can effectively suppress the dynamic response of wind turbine blades

  2. Gas Turbine Blade Damper Optimization Methodology

    OpenAIRE

    R. K. Giridhar; P. V. Ramaiah; G. Krishnaiah; S. G. Barad

    2012-01-01

    The friction damping concept is widely used to reduce resonance stresses in gas turbines. A friction damper has been designed for high pressure turbine stage of a turbojet engine. The objective of this work is to find out effectiveness of the damper while minimizing resonant stresses for sixth and ninth engine order excitation of first flexure mode. This paper presents a methodology that combines three essential phases of friction damping optimization in turbo-machinery. The first phase is to...

  3. A new magnetorheological damper with improved displacement differential self-induced ability

    International Nuclear Information System (INIS)

    Hu, Guoliang; Zhou, Wei; Li, Weihua

    2015-01-01

    This work is an extension of our previous study on the development of a linear variable differential sensor (LVDS)-based magnetorheological (MR) damper with self-sensing capability, where a new MR damper integrated with LVDS technology was developed and prototyped, then its self-induced performance under static and dynamic working conditions was experimentally evaluated. The results of the static and dynamic experiments indicated that the self-induced voltage was proportional to the displacement of the damper. Moreover, the damping performance of this new MR damper was also evaluated through an experimental study. Compared with our previous study, the new MR damper performed better in terms of its self-induced sensing ability and damping capacity. (technical note)

  4. Design and characterization of axial flux permanent magnet energy harvester for vehicle magnetorheological damper

    International Nuclear Information System (INIS)

    Dong, Xiaomin

    2016-01-01

    An axial flux permanent magnet energy harvester (AFPMEH) is proposed and analyzed for a vehicle magneto-rheological (MR) damper. The relationship between the output voltage and the input excitations are analytically developed. Under different constant rotation speeds and sinusoidal excitations, the harvesting energy is numerically computed for different loads of pure resistance and coil in the MR damper. To check the performance of the proposed AFPMEH for the MR damper, the AFPMEH and MR damper are fabricated individually. Experiments are performed to measure the harvesting energy of the AFPMEH and the damping characteristics of the MR damper under different excited conditions. The excited conditions include three constant rotation speeds and sinusoidal inputs. Load inputs of the pure resistance and the coil of the MR damper are considered. The results show that the time history of the generated voltage of the AFPMEH in experiment is agreed well with that of the AFPMEH in simulation. Under constant rotation speeds, the root mean square (rms) of loaded voltage will increase with the increment of load, whereas the rms of power will be affected by the amplitude of load. The MR damper powered by the AFPMEH can almost obtain the similar damping characteristics of that external power supply. Under sinusoidal inputs, the rms of loaded voltage will increase with the increment of external loads, whereas the rms of power will be almost kept as a constant. The damping range of the MR damper can also be enlarged over 30% comparing to off-state damping force. A quarter car model with an MR damper powered by the AFPMEH is developed to investigate the control performance. The on–off skyhook control is adopted to tune the input current of the MR damper. The vibration performance of the MR suspension is investigated under different roads and vehicle speeds. The numerical results show that the MR suspension with the AFPMEH under on–off skyhook control can achieve better ride

  5. Innovative design of viscoelastic dampers for seismic mitigation

    International Nuclear Information System (INIS)

    Tsai, C.S.

    1993-01-01

    In this paper, an advanced and more reliable design of viscoelastic dampers for seismic mitigation of high-rise buildings is presented. The innovative design of energy-absorbing devices has some advantages, compared to the classical design, as follows: One, the device is directly subjected to shear strains and forces due to story drifts; two, the device can support its own weight during normal operations, and maintain stable for large deformations during earthquakes; three, the device can reduce the responses of a structure to horizontal as well as vertical seismic loadings; and four, the device can also decrease the responses of the floor system of a building. In this study, a ten-story building is given as an example to express the merits obtained from the new system. Comparisons of the building equipped with classical and proposed devices of viscoelastic dampers are carefully studied. Numerical results show that the energy-absorbing capacity of the new device is superior to the classical one, especially for vertical vibrations. (orig.)

  6. Improvement of Ride Quality of Railway Vehicle by Semiactive Secondary Suspension System on Roller Rig Using Magnetorheological Damper

    Directory of Open Access Journals (Sweden)

    Yu-Jeong Shin

    2014-07-01

    Full Text Available Ride quality became a very important factor in the performance of railway vehicles according to the expansion of high-speed railways and speedup of velocity of railway vehicles. In this study, the results of applying the MR (magnetorheological lateral damper on the secondary suspension to reduce the vibration of the car body, directly relating to the ride quality of railway vehicles, were mentioned. In order to verify the control performance of MR dampers, a 1/5 scaled railway vehicle model was constructed, and numerical simulation and experimental tests were conducted. The MR damper for the experimental tests was produced and was attached between the car body and bogie of a full scaled vehicle, and a vibration controlling test was performed to improve ride quality on a roller rig. The skyhook control algorithm was used as the controlling technique, and regarding the test results, the RMS (root mean square value was found by compensating the frequency of the lateral vibration based on the UIC 513 R Standard about the ride quality of railway vehicles. As a result of the test, it could be confirmed that vibration was reduced by approximately 24% when attaching the MR damper between the bogie and the car body compared to when applying a passive damper.

  7. Development of semi-active hydraulic damper as active interaction ...

    Indian Academy of Sciences (India)

    Semi-auto controller; displacement semi-active hydraulic damper; ... 2000), and Magnetorheological Damper (Dyke et al 1998) were widely discussed or used. ... driving force provided by electrical motor causes the subordinate structure to ...

  8. The application of viscous dampers as pipe restraints

    International Nuclear Information System (INIS)

    Keowen, R.S.; Hueffmann, G.; Mays, B.; Rencher, D.

    1993-01-01

    Dynamic loading of power generation piping systems may result in nonpermissable deflections and stresses. Fatigue failure translate to increased maintenance costs and possible lost revenue. Undesirable loading can occur due to external events such as earthquakes and internal events such as water and steam hammer, two-phase flow and cavitation. Sway braces and snubbers have been employed to reduce the negative effects of piping motion in emergency cases, however, repetitive loading due to internal events has caused premature wear and failure. Visco elastic dampers, however, have proven to be piping response due to slugging, steam hammer and other repetitive loads. Functional and modeling aspects of visco elastic dampers are discussed, experimental evidence of their effectiveness in a steam hammer application is presented and examples of primary coolant loop restraint applications are illustrated

  9. Analytical and experimental investigation on a multiple-mass-element pendulum impact damper for vibration mitigation

    Science.gov (United States)

    Egger, Philipp; Caracoglia, Luca

    2015-09-01

    Impact dampers are often used in the field of civil, mechanical and aerospace engineering for reducing structural vibrations. The behavior of this type of passive control device has been investigated for several decades. In this research a distributed-mass impact damper, similar to the "chain damper" used in wind engineering, has been examined and applied to the vibration reduction on a slender line-like structural element (stay-cable). This study is motivated by a practical problem and describes the derivation of a reduced-order model for explaining the behavior, observed during a field experiment on a prototype system. In its simplest form, the dynamics of the apparatus is modeled as a "resilient damper", composed of mass-spring-dashpot secondary elements, attached to the primary structure. Various sources of excitation are analyzed: free vibration, external harmonic force and random excitation. The proposed model is general and potentially applicable to the analysis of several structural systems. The study also shows that the model can adequately describe and explain the experimentally observed behavior.

  10. An equivalent method for optimization of particle tuned mass damper based on experimental parametric study

    Science.gov (United States)

    Lu, Zheng; Chen, Xiaoyi; Zhou, Ying

    2018-04-01

    A particle tuned mass damper (PTMD) is a creative combination of a widely used tuned mass damper (TMD) and an efficient particle damper (PD) in the vibration control area. The performance of a one-storey steel frame attached with a PTMD is investigated through free vibration and shaking table tests. The influence of some key parameters (filling ratio of particles, auxiliary mass ratio, and particle density) on the vibration control effects is investigated, and it is shown that the attenuation level significantly depends on the filling ratio of particles. According to the experimental parametric study, some guidelines for optimization of the PTMD that mainly consider the filling ratio are proposed. Furthermore, an approximate analytical solution based on the concept of an equivalent single-particle damper is proposed, and it shows satisfied agreement between the simulation and experimental results. This simplified method is then used for the preliminary optimal design of a PTMD system, and a case study of a PTMD system attached to a five-storey steel structure following this optimization process is presented.

  11. Elastomer damper performance - A comparison with a squeeze film for a supercritical power transmission shaft

    Science.gov (United States)

    Zorzi, E. S.; Burgess, G.; Cunningham, R.

    1980-01-01

    This paper describes the design and testing of an elastomer damper on a super-critical power transmission shaft. The elastomers were designed to provide acceptable operation through the fourth bending mode and to control synchronous as well as nonsynchronous vibration throughout the operating range. The design of the elastomer was such that it could be incorporated into the system as a replacement for a squeeze-film damper without a reassembly, which could have altered the imbalance of the shaft. This provided a direct comparison of the elastomer and squeeze-film dampers without having to assess the effect of shaft imbalance changes.

  12. SEISMIC Analysis of high-rise buildings with composite metal damper

    Directory of Open Access Journals (Sweden)

    Chen Ruixue

    2015-01-01

    Full Text Available This paper mainly studies on the mechanical characteristics and application effect of composite metal damper in the high-rise buildings via the numerical simulation analysis. The research adopts the elastic and elastic-plastic dynamic approach and the displacement time history response and damper energy dissipation capacity and so on of the high-rise building are compared and analyzed before and after installation. The analysis found that the energy dissipation characteristic of metallic dampers is good. High-rise building story drift significantly is reduced and the extent of damage of the walls and coupling beams is decreased, achieved a good energy dissipation effect. Composite metal damper can effectively and economically improve the seismic performance of high-rise buildings, meet the requirement of the 3-level design for seismic resistance. The result has certain reference significance for the application of metallic damper in the high-rise buildings.

  13. Edgewise vibration control of wind turbine blades using roller and liquid dampers

    DEFF Research Database (Denmark)

    Zhang, Zili; Nielsen, Søren R.K.

    2014-01-01

    suppressing edgewise vibrations. The roller dampers are more volumetrically efficient due to the higher mass density of the steel comparing with the liquid. On the other hand, TLCDs have their advantage that it is easier to specify the optimum damping of the damper by changing the opening ratio of the orifice......This paper deals with the passive vibration control of edgewise vibrations by means of roller dampers and tuned liquid column dampers (TLCDs). For a rotating blade, the large centrifugal acceleration makes it possible to use roller dampers or TLCDs with rather small masses for effectively...

  14. Dynamic modeling and simulation of sheave damper based on AMESim software

    Directory of Open Access Journals (Sweden)

    BI Ke

    2017-10-01

    Full Text Available [Objectives] Considering the shortcomings of the traditional sheave damper in buffer performance and the peak value of the greatest cable tension,[Methods] this paper presents a sheave damper with variable damping according to piston displacement as a replacement for the traditional sheave damper, and AMESim software is used for the modeling and simulation.[Results] The results show that the new sheave damper can significantly improve the arresting gear performance indicators, and has better adaptability for aircraft impact load. Compared with the traditional sheave damper, the new method can reduce cable tension by 25% and reduce the maximum deceleration of aircraft by 23%.[Conclusions] As such, the research in this paper can provide a theoretical reference for improving the performance of aircraft arresting gear.

  15. Design and analysis of a magneto-rheological damper for an all terrain vehicle

    Science.gov (United States)

    Krishnan Unni, R.; Tamilarasan, N.

    2018-02-01

    A shock absorber design intended to replace the existing conventional shock absorber with a controllable system using a Magneto-rheological damper is introduced for an All Terrain Vehicle (ATV) that was designed for Baja SAE competitions. Suspensions are a vital part of an All Terrain Vehicles as it endures various surfaces and requires utmost attention while designing. COMSOL multi-physics software is used for applications that have coupled physics problems and is a unique tool that is used for the designing and analysis phase of the Magneto-rheological damper for the considered application and the model is optimized based on Taguchi using DOE software. The magneto-rheological damper is designed to maximize the damping force with the measured geometric constraints for the All Terrain Vehicle.

  16. Nonlinear modeling of adaptive magnetorheological landing gear dampers under impact conditions

    Science.gov (United States)

    Ahuré Powell, Louise A.; Choi, Young T.; Hu, Wei; Wereley, Norman M.

    2016-11-01

    Adaptive landing gear dampers that can continuously adjust their stroking load in response to various operating conditions have been investigated for improving the landing performance of a lightweight helicopter. In prior work, adaptive magnetorheological (MR) landing gear dampers that maintained a constant peak stroking force of 4000 lbf across sink rates ranging from 6 to 12 ft s-1 were designed, fabricated and successfully tested. In this follow-on effort, it is desired to expand the high end of the sink rate range to hold the peak stroking load constant for sink rates ranging from 6 to 26 ft s-1, thus extending the high end of the speed range from 12 (in the first study) to 26 ft s-1. To achieve this increase, a spring-based relief valve MR landing gear damper was developed. In order to better understand the MR landing gear damper behavior, a modified nonlinear Bingham Plastic model was formulated, and it incorporates Darcy friction, viscous forces across the MR and relief valves to better account for the damper force behavior at higher speeds. In addition, gas pressure inside the MR damper piston is considered so the total damper force includes a gas force. The MR landing gear damper performance is characterized using drop tests, and the experiments are used to validate model predictions data at low and high nominal impact speeds up to 26 ft s-1 (shaft velocity of 9.6 ft s-1).

  17. Influence of the story stiffness of reinforced concrete frame with proportional hysteretic dampers on the seismic response

    OpenAIRE

    Oviedo, J. A. (Juan Andrés)

    2011-01-01

    This paper investigates the influence of the story stiffness of reinforced concrete (R/C) frame on the seismic response of R/C buildings with proportional hysteretic dampers. For this purpose, non-linear time-history analyses were conducted on a series of multi-degree-of-freedom system models that include a wide range of structural parameters and vertical distributions of story stiffnesses and strengths of R/C main frame and dampers. Although the basic purpose of damper installation is to red...

  18. Rail vehicle dynamic response to a nonlinear physical 'in-service' model of its secondary suspension hydraulic dampers

    Science.gov (United States)

    Wang, W. L.; Zhou, Z. R.; Yu, D. S.; Qin, Q. H.; Iwnicki, S.

    2017-10-01

    A full nonlinear physical 'in-service' model was built for a rail vehicle secondary suspension hydraulic damper with shim-pack-type valves. In the modelling process, a shim pack deflection theory with an equivalent-pressure correction factor was proposed, and a Finite Element Analysis (FEA) approach was applied. Bench test results validated the damper model over its full velocity range and thus also proved that the proposed shim pack deflection theory and the FEA-based parameter identification approach are effective. The validated full damper model was subsequently incorporated into a detailed vehicle dynamics simulation to study how its key in-service parameter variations influence the secondary-suspension-related vehicle system dynamics. The obtained nonlinear physical in-service damper model and the vehicle dynamic response characteristics in this study could be used in the product design optimization and nonlinear optimal specifications of high-speed rail hydraulic dampers.

  19. Fabrication and testing of an energy-harvesting hydraulic damper

    International Nuclear Information System (INIS)

    Li, Chuan; Tse, Peter W

    2013-01-01

    Hydraulic dampers are widely used to dissipate energy during vibration damping. In this paper, an energy-harvesting hydraulic damper is proposed for collecting energy while simultaneously damping vibration. Under vibratory excitation, the flow of hydraulic oil inside the cylinder of the damper is converted into amplified rotation via a hydraulic motor, whose output shaft is connected to an electromagnetic generator capable of harvesting a large amount of energy. In this way, the vibration is damped by both oil viscosity and the operation of an electrical mechanism. An electromechanical model is presented to illustrate both the electrical and mechanical responses of the system. A three-stage identification approach is introduced to facilitate the model parameter identification using cycle-loading experiments. A prototype device is developed and characterized in a test rig. The maximum power harvested during the experiments was 435.1 W (m s −1 ) −1 , using a predefined harmonic excitation with an amplitude of 0.02 m, a frequency of 0.8 Hz, and an optimal resistance of 2 Ω. Comparison of the experimental and computational results confirmed the effectiveness of both the electromechanical model and the three-stage identification approach in realizing the proposed design. (paper)

  20. Passivity Enhancement of Grid-Tied Converter by Series LC-Filtered Active Damper

    DEFF Research Database (Denmark)

    Bai, Haofeng; Wang, Xiongfei; Loh, Poh Chiang

    2015-01-01

    attention. Also, parasitic capacitance of the grid transmission line brings new challenge for the application of an active damper, which has not been discussed before. In order to fill these gaps, this paper first analyzes the stability of a grid-tied converter with the help of passivity. Based......Series LC-filtered active damper can be used to stabilize the grid-tied voltage source converter in a non-ideal grid. The operation principle of the active damper is to mimic a damping resistance at the resonance frequencies. However, the selection of the damping resistance has not received much...... on the passivity-based-stability analysis, a damping resistance selection method is proposed. Then, an admittance shaping method is developed to ensure the system stability in the presence of parasitic capacitance of the transmission line. Finally, experimental results are provided to show the validity...

  1. An innovative magnetorheological damper for automotive suspension: from design to experimental characterization

    Science.gov (United States)

    Sassi, Sadok; Cherif, Khaled; Mezghani, Lotfi; Thomas, Marc; Kotrane, Asma

    2005-08-01

    The development of a powerful new magnetorheological fluid (MRF), together with recent progress in the understanding of the behavior of such fluids, has convinced researchers and engineers that MRF dampers are among the most promising devices for semi-active automotive suspension vibration control, because of their large force capacity and their inherent ability to provide a simple, fast and robust interface between electronic controls and mechanical components. In this paper, theoretical and experimental studies are performed for the design, development and testing of a completely new MRF damper model that can be used for the semi-active control of automotive suspensions. The MR damper technology presented in this paper is based on a completely new approach where, in contrast to in the conventional solutions where the coil axis is usually superposed on the damper axis and where the inner cylindrical housing is part of the magnetic circuit, the coils are wound in a direction perpendicular to the damper axis. The paper investigates approaches to optimizing the dynamic response and provides experimental verification. Both experimental and theoretical results have shown that, if this particular model is filled with an 'MRF 336AG' MR fluid, it can provide large controllable damping forces that require only a small amount of energy. For a magnetizing system with four coils, the damping coefficient could be increased by up to three times for an excitation current of only 2 A. Such current could be reduced to less than 1 A if the magnetizing system used eight small cores. In this case, the magnetic field will be more powerful and more regularly distributed. In the presence of harmonic excitation, such a design will allow the optimum compromise between comfort and stability to be reached over different intervals of the excitation frequencies.

  2. Unsteady flow damping force prediction of MR dampers subjected to sinusoidal loading

    Science.gov (United States)

    Yu, M.; Wang, S. Q.; Fu, J.; Peng, Y. X.

    2013-02-01

    So far quasi-steady models are usually used to design magnetorheological (MR) dampers, but these models are not sufficient to describe the MR damper behavior under unsteady dynamic loading, for fluid inertia is neglected in quasi-steady models, which will bring more error between computer simulation and experimental results. Under unsteady flow model, the fluid inertia terms will bring error calculated upto 10%, so it is necessary to be considered in the governing equation. In this paper, force-stroke behavior of MR damper with flow mode due to sinusoidal loading excitation is mainly investigated, to simplify the analysis, the one-dimensional axisymmetric annular duct geometry of MR dampers is approximated as a rectangular duct. The rectangular duct can be divided into 3 regions for the velocity profile of the incompressible MR fluid flow, in each region, a partial differential equation is composed of by Navier-Stokes equations, boundary conditions and initial conditions to determine the velocity solution. In addition, in this work, not only Bingham plastic model but the Herschel—Bulkley model is adopted to analyze the MR damper performance. The damping force resulting from the pressure drop of unsteady MR dampers can be obtained and used to design or size MR dampers. Compared with the quasi-steady flow damping force, the damping force of unsteady MR dampers is more close to practice, particularly for the high-speed unsteady movement of MR dampers.

  3. Unsteady flow damping force prediction of MR dampers subjected to sinusoidal loading

    International Nuclear Information System (INIS)

    Yu, M; Fu, J; Wang, S Q; Peng, Y X

    2013-01-01

    So far quasi-steady models are usually used to design magnetorheological (MR) dampers, but these models are not sufficient to describe the MR damper behavior under unsteady dynamic loading, for fluid inertia is neglected in quasi-steady models, which will bring more error between computer simulation and experimental results. Under unsteady flow model, the fluid inertia terms will bring error calculated upto 10%, so it is necessary to be considered in the governing equation. In this paper, force-stroke behavior of MR damper with flow mode due to sinusoidal loading excitation is mainly investigated, to simplify the analysis, the one-dimensional axisymmetric annular duct geometry of MR dampers is approximated as a rectangular duct. The rectangular duct can be divided into 3 regions for the velocity profile of the incompressible MR fluid flow, in each region, a partial differential equation is composed of by Navier-Stokes equations, boundary conditions and initial conditions to determine the velocity solution. In addition, in this work, not only Bingham plastic model but the Herschel—Bulkley model is adopted to analyze the MR damper performance. The damping force resulting from the pressure drop of unsteady MR dampers can be obtained and used to design or size MR dampers. Compared with the quasi-steady flow damping force, the damping force of unsteady MR dampers is more close to practice, particularly for the high-speed unsteady movement of MR dampers.

  4. Damping characteristics and flow behaviors of an ER fluid with a piston sine vibration in a viscous damper

    International Nuclear Information System (INIS)

    Yamaguchi, Hiroshi; Zhang, Xin-Rong; Niu, Xiao-Dong

    2010-01-01

    The damping characteristics and flow behaviors of ER fluids inside a piston–cylinder viscous damper subjected to external electric fields are studied based on experiment, theoretical analysis and numerical simulation. The viscous damper is a closed system with an inner piston and an outer cylinder, which is designed and constructed in our laboratory. In the experiment, the test ER fluid is enclosed in the gap of a piston–cylinder system. To examine the damping characteristics of the test ER fluid, a piston sine vibration experiment is performed with accompanying theoretical analyses. In addition, in order to investigate the ER flow behaviors inside the damper, a numerical simulation is carried out. The present study discloses the damping characteristics and the fluid mechanism of the ER fluid in the piston–cylinder damper with an applied external electric field

  5. Semi-active control of tracked vehicle suspension incorporating magnetorheological dampers

    Science.gov (United States)

    Ata, W. G.; Salem, A. M.

    2017-05-01

    In past years, the application of magnetorheological (MR) and electrorheological dampers in vehicle suspension has been widely studied, mainly for the purpose of vibration control. This paper presents theoretical study to identify an appropriate semi-active control method for MR-tracked vehicle suspension. Three representative control algorithms are simulated including the skyhook, hybrid and fuzzy-hybrid controllers. A seven degrees-of-freedom tracked vehicle suspension model incorporating MR dampers has been adopted for comparison between the performance of the three controllers. The model differential equations are derived based on Newton's second law of motion and the proposed control methods are developed. The performance of each control method under bump and sinusoidal road profiles for different vehicle speeds is simulated and compared with the performance of the conventional suspension system in time and frequency domains. The results show that the performance of tracked vehicle suspension with MR dampers is substantially improved. Moreover, the fuzzy-hybrid controller offers an excellent integrated performance in reducing the body accelerations as well as wheel bounce responses compared with the classical skyhook and hybrid controllers.

  6. Damper mechanism for nuclear reactor control elements

    International Nuclear Information System (INIS)

    Taft, W.E.

    1976-01-01

    A damper mechanism which provides a nuclear reactor control element decelerating function at the end of the scram stroke is described. The total damping function is produced by the combination of two assemblies, which operate in sequence. First, a tapered dashram assembly decelerates the control element to a lower velocity, after which a spring hydraulic damper assembly takes over to complete the final damping. 3 claims, 2 figures

  7. Time delay effects on large-scale MR damper based semi-active control strategies

    International Nuclear Information System (INIS)

    Cha, Y-J; Agrawal, A K; Dyke, S J

    2013-01-01

    This paper presents a detailed investigation on the robustness of large-scale 200 kN MR damper based semi-active control strategies in the presence of time delays in the control system. Although the effects of time delay on stability and performance degradation of an actively controlled system have been investigated extensively by many researchers, degradation in the performance of semi-active systems due to time delay has yet to be investigated. Since semi-active systems are inherently stable, instability problems due to time delay are unlikely to arise. This paper investigates the effects of time delay on the performance of a building with a large-scale MR damper, using numerical simulations of near- and far-field earthquakes. The MR damper is considered to be controlled by four different semi-active control algorithms, namely (i) clipped-optimal control (COC), (ii) decentralized output feedback polynomial control (DOFPC), (iii) Lyapunov control, and (iv) simple-passive control (SPC). It is observed that all controllers except for the COC are significantly robust with respect to time delay. On the other hand, the clipped-optimal controller should be integrated with a compensator to improve the performance in the presence of time delay. (paper)

  8. DARHT-II Injector Transients and the Ferrite Damper

    Energy Technology Data Exchange (ETDEWEB)

    Waldron, Will; Reginato, Lou; Chow, Ken; Houck, Tim; Henestroza, Enrique; Yu, Simon; Kang, Michael; Briggs, Richard

    2006-08-04

    This report summarizes the transient response of the DARHT-II Injector and the design of the ferrite damper. Initial commissioning of the injector revealed a rise time excited 7.8 MHz oscillation on the diode voltage and stalk current leading to a 7.8 MHz modulation of the beam current, position, and energy. Commissioning also revealed that the use of the crowbar to decrease the voltage fall time excited a spectrum of radio frequency modes which caused concern that there might be significant transient RF electric field stresses imposed on the high voltage column insulators. Based on the experience of damping the induction cell RF modes with ferrite, the concept of a ferrite damper was developed to address the crowbar-excited oscillations as well as the rise-time-excited 7.8 MHz oscillations. After the Project decided to discontinue the use of the crowbar, further development of the concept focused exclusively on damping the oscillations excited by the rise time. The design was completed and the ferrite damper was installed in the DARHT-II Injector in February 2006. The organization of this report is as follows. The suite of injector diagnostics are described in Section 2. The data and modeling of the injector transients excited on the rise-time and also by the crowbar are discussed in Section 3; the objective is a concise summary of the present state of understanding. The design of the ferrite damper, and the small scale circuit simulations used to evaluate the ferrite material options and select the key design parameters like the cross sectional area and the optimum gap width, are presented in Section 4. The details of the mechanical design and the installation of the ferrite damper are covered in Section 5. A brief summary of the performance of the ferrite damper following its installation in the injector is presented in Section 6.

  9. Study on lead extrusion damper as a seismic support

    International Nuclear Information System (INIS)

    Nomura, T.; Kojima, N.; Fujita, K.; Ito, T.

    1989-01-01

    The fundamental characteristics of two types of lead extrusion dampers (cylinder type, rotary type) for use as the nuclear power plant piping support of the elasto-plastic of damper are clarified. As a result, these lead extrusion dampers are found to have the following dynamic characteristics: hysteresis loop is both rectangular shape and bi-linear shape; maximum reaction force is independent of velocity and frequency but it increases as displacement exceeds the specified value; and the dissipated energy is very large and is independent of velocity, frequency and initial displacement (i.e., thermal expansion of pipings) in the range of test

  10. Effects of elasticity on the damping characteristics of viscous shearing damper and estimation curve for modal damping in stay cables with this type of dampers. Cable seishin'yo nensei sendangata damper no gensui fuka tokusei ni oyobosu banegosei no eikyo to sono sekkeiyo gensui hyoka kyokusen

    Energy Technology Data Exchange (ETDEWEB)

    Yoneda, M. (Kawada Industries Inc., Tokyo (Japan)); Shimoda, I. (Oiles Corp., Tokyo (Japan))

    1993-12-20

    Oil dampers and viscous shearing dampers have been used to control wind-induced cable vibrations of cable-stayed bridges. The damping addition efficiency in the case where only damping force of the viscous shearing damper is considered was discussed in the previous paper. In this paper, more precise estimation is done by also considering the spring elasticity of the damper. Arranging the results of an indoor excitation test on viscous shearing dampers using SA-P viscous body, an experimental equation to express the spring rigidity is derived. The spring elasticity becomes smaller with increasing temperature of viscous body, decreasing frequency, and increasing amplitude. Then, the damping addition effect is measured by installing the viscous shearing damper on the actual bridge cable, and is compared with the theoretical value resulting from the complex-eigenvalue analysis. Consequently, it is shown that the theoretical value is almost correspondent with the measured result through the analysis using equivalent coefficient of viscosity and equivalent spring constant, which are arranged in the experimental equation. Moreover, application examples of damping estimation curves for designing cables with dampers are given. 15 refs., 13 figs., 10 tabs.

  11. Reduction of seismic response long-span PC cable-stayed bridge by passive dampers; Damper ni yoru saidai PC shachokyo no jishinji oto no teigen

    Energy Technology Data Exchange (ETDEWEB)

    Takeda, T.; Yamanobe, S.; Niihara, Y. [Kajima Corp., Tokyo (Japan)

    1994-10-31

    It is important in designing a PC cable-stayed bridge to properly estimate the seismic response of the bridge for reduction of the response. In this paper, an improvement of the seismic resistance of PC cable-stayed bridges when dampers are installed between the deck and piers and lateral vibration of the deck is restricted is investigated using a time history response model. PC cable-stayed bridges with a span length of 400 m, particularly two types of bridges of harp and semi-harp are investigated and the following is found by analyzing the case where there are installed hysteresis type dampers (with 1 cm yield displacement and secondary rigidity assumed to be 1/10 times that of initial rigidity, the initial rigidity being parametrically changed.) or viscous type dampers (a damping factor is changed.) The result shows that the dampers can reduce the seismic response of a PC cable-stayed bridge and that a semi-harp configuration of stay cables where stay cable members are substantially vertically arranged is more effective than a harp configuration for the seismic performance of PC cable-stayed bridges. The damper partly bear inertial force of the bridge upon earthquake whereby tension of the stay cable members is reduced and bending moment of the deck is reduced. There is existing an optimum characteristic value of the damper concerning the bending moment of the piers. 5 refs., 7 figs., 2 tabs.

  12. The resistive instability damper system for the first stage of the UNK accelerator with IIR-filter in feedback

    International Nuclear Information System (INIS)

    Zhabitskij, V.M.; Korenev, I.L.; Yudin, L.A.

    1991-01-01

    The resistive instability damper system for the coasting beam in the accelerator is discussed. The system for each of two directions of beam transverse coherent oscillations includes two pairs of pick-up electrodes and damping kickers connected by delayed negative feedback. It has been shown that damping regime can be achieved for one and the same pick-up and kicker location independently on imQ. 8 refs.; 4 figs

  13. Evaluation of dampers using a resonance adhesion tester

    Directory of Open Access Journals (Sweden)

    Stanislav Koláček

    2013-01-01

    Full Text Available This paper describes the diagnostics of dampers using resonant adhesion tester. This kind of test is non-invasive and evaluation is based on the EUSAMA methodology. The main goals of this method were to practically measure and evaluate technical condition of the shock absorbers. However, this method does not measure only damper properties, but the whole axle, too. During measurements, one must take into account the fact that the results can be easily influenced by external factors. These include e.g. wrong tire pressure, different kind of shock absorbers, and tires. The actual testing revealed that the measurement results are also influenced by bad condition of the vehicle axles. If we eliminate all these draw-backs, dampers testing can be very accurate.

  14. Experimental analysis of large capacity MR dampers with short- and long-stroke

    Science.gov (United States)

    Zemp, René; de la Llera, Juan Carlos; Weber, Felix

    2014-12-01

    The purpose of this article is to study and characterize experimentally two magneto-rheological dampers with short- and long-stroke, denoted hereafter as MRD-S and MRD-L. The latter was designed to improve the Earthquake performance of a 21-story reinforced concrete building equipped with two 160 ton tuned pendular masses. The MRD-L has a nominal force capacity of 300 kN and a stroke of ±1 m; the MRD-S has a nominal force capacity of 150 kN, and a stroke of ±0.1 m. The MRD-S was tested with two different magneto-rheological and one viscous fluid. Due to the presence of Eddy currents, both dampers show a time lag between current intensity and damper force as the magnetization on the damper changes in time. Experimental results from the MRD-L show a force drop-off behavior. A decrease in active-mode forces due to temperature increase is also analyzed for the MRD-S and the different fluids. Moreover, the observed increase in internal damper pressure due to energy dissipation is evaluated for the different fluids in both dampers. An analytical model to predict internal pressure increase in the damper is proposed that includes as a parameter the concentration of magnetic particles inside the fluid. Analytical dynamic pressure results are validated using the experimental tests. Finally, an extended Bingham fluid model, which considers compressibility of the fluid, is also proposed and validated using damper tests.

  15. Experimental analysis of large capacity MR dampers with short- and long-stroke

    International Nuclear Information System (INIS)

    Zemp, René; De la Llera, Juan Carlos; Weber, Felix

    2014-01-01

    The purpose of this article is to study and characterize experimentally two magneto-rheological dampers with short- and long-stroke, denoted hereafter as MRD-S and MRD-L. The latter was designed to improve the Earthquake performance of a 21-story reinforced concrete building equipped with two 160 ton tuned pendular masses. The MRD-L has a nominal force capacity of 300 kN and a stroke of ±1 m; the MRD-S has a nominal force capacity of 150 kN, and a stroke of ±0.1 m. The MRD-S was tested with two different magneto-rheological and one viscous fluid. Due to the presence of Eddy currents, both dampers show a time lag between current intensity and damper force as the magnetization on the damper changes in time. Experimental results from the MRD-L show a force drop-off behavior. A decrease in active-mode forces due to temperature increase is also analyzed for the MRD-S and the different fluids. Moreover, the observed increase in internal damper pressure due to energy dissipation is evaluated for the different fluids in both dampers. An analytical model to predict internal pressure increase in the damper is proposed that includes as a parameter the concentration of magnetic particles inside the fluid. Analytical dynamic pressure results are validated using the experimental tests. Finally, an extended Bingham fluid model, which considers compressibility of the fluid, is also proposed and validated using damper tests. (paper)

  16. Investigation of optimal seismic design methodology for piping systems supported by elasto-plastic dampers. Part. 2. Applicability for seismic waves with various frequency characteristics

    International Nuclear Information System (INIS)

    Ito, Tomohiro; Michiue, Masashi; Fujita, Katsuhisa

    2010-01-01

    In this study, the applicability of a previously developed optimal seismic design methodology, which can consider the structural integrity of not only piping systems but also elasto-plastic supporting devices, is studied for seismic waves with various frequency characteristics. This methodology employs a genetic algorithm and can search the optimal conditions such as the supporting location and the capacity and stiffness of the supporting devices. Here, a lead extrusion damper is treated as a typical elasto-plastic damper. Numerical simulations are performed using a simple piping system model. As a result, it is shown that the proposed optimal seismic design methodology is applicable to the seismic design of piping systems subjected to seismic waves with various frequency characteristics. The mechanism of optimization is also clarified. (author)

  17. Power turbine dynamics - An evaluation of a shear-mounted elastomeric damper

    Science.gov (United States)

    Zorzi, E. S.; Walton, J.; Cunningham, R.

    1983-01-01

    As an alternative to the more conventional squeeze-film bearing damper designs, a Viton-70 shear-mounted, elastomeric damper was built and tested in a T-55 power turbine high-speed balancing rig. This application demonstrated, for the first time, the feasibility of using elastomers as the primary rotor damping source in production turbine engine hardware. The shear-mounted damper design was selected because of its compatibility with actual gas turbine engine radial space constraints, its accommodation of both the radial and axial thrust loads present in gas turbine engines, and its capability of controlled axial preload. Test results showed that the Viton-70 elastomeric damper operated successfully and provided excellent control of both synchronous and nonsynchronous vibrations through all phases of testing to the maximum rotor speed of 1676 rad/s (16,000 rpm). Excellent correlation between the predicted and experienced critical speeds, mode shapes, and log decrements for the power turbine rotor and elastomer damper assembly was also achieved.

  18. Experimental Study of Hysteretic Steel Damper for Energy Dissipation Capacity

    Directory of Open Access Journals (Sweden)

    Daniel R. Teruna

    2015-01-01

    Full Text Available This study aims to evaluate energy absorption capacity of hysteretic steel damper for earthquake protection of structures. These types of steel dampers are fabricated from mild steel plate with different geometrical shapes on the side part, namely, straight, concave, and convex shapes. The performance of the proposed device was verified experimentally by a series of tests under increasing in-plane cyclic load. The overall test results indicated that the proposed steel dampers have similar hysteretic curves, but the specimen with convex-shaped side not only showed stable hysteretic behavior but also showed excellent energy dissipation capabilities and ductility factor. Furthermore, the load-deformation relation of these steel dampers can be decomposed into three parts, namely, skeleton curve, Bauschinger part, and elastic unloading part. The skeleton curve is commonly used to obtain the main parameters, which describe the behavior of steel damper, namely, yield strength, elastic stiffness, and postyield stiffness ratio. Moreover, the effective stiffness, effective damping ratio, cumulative plastic strain energy, and cumulative ductility factor were also derived from the results. Finally, an approximation trilinear hysteretic model was developed based on skeleton curve obtained from experimental results.

  19. Vibration Control of Novel Passive Multi-joints Rotational Friction Dampers

    DEFF Research Database (Denmark)

    Mualla, Imad H.; Koss, Holger

    2017-01-01

    that the damper performance is: - Independent of forcing frequency within applicable range - Linearly dependent on displacement amplitudes - Linearly dependent on normal forces - Very stable over many cycles Furthermore, a numerical model of the 4-joint damper has been developed based on an analytical derivation...... that are supplied by Damptech A/S have been installed in many projects in Japan, among them Japan tallest building and in other countries around the world. The paper provides a number of show cases demonstrating versatile application of rotational friction dampers (RFD)....... or strong winds. The damper is based on a rotational friction concept that was developed by Mualla, I.H. The devices have a stable energy dissipating behavior. They are flexible in the application, since they only need limited space. The devices can be installed easily. The damping capacity of the devices...

  20. Optimizing of the higher order mode dampers in the 56MHz SRF cavity

    International Nuclear Information System (INIS)

    Wu, Q.; Ben-Zvi, I.

    2010-01-01

    Earlier, we reported that a 56 MHz cavity was designed for a luminosity upgrade of the RHIC, and presented the requirements for Higher Order Mode (HOM) damping, the design of the HOM dampers, along with measurements and simulations of the HOM dampers. In this report, we describe our optimization of the dampers performance, and the modifications we made to their original design. We also optimized the number of the HOM dampers, and tested different configurations of locations for them.

  1. Experimental calibration of forward and inverse neural networks for rotary type magnetorheological damper

    DEFF Research Database (Denmark)

    Bhowmik, Subrata; Weber, Felix; Høgsberg, Jan Becker

    2013-01-01

    This paper presents a systematic design and training procedure for the feed-forward backpropagation neural network (NN) modeling of both forward and inverse behavior of a rotary magnetorheological (MR) damper based on experimental data. For the forward damper model, with damper force as output...

  2. The effect of friction in coulombian damper

    Science.gov (United States)

    Wahad, H. S.; Tudor, A.; Vlase, M.; Cerbu, N.; Subhi, K. A.

    2017-02-01

    The study aimed to analyze the damping phenomenon in a system with variable friction, Stribeck type. Shock absorbers with limit and dry friction, is called coulombian shock-absorbers. The physical damping vibration phenomenon, in equipment, is based on friction between the cushioning gasket and the output regulator of the shock-absorber. Friction between them can be dry, limit, mixture or fluid. The friction is depending on the contact pressure and lubricant presence. It is defined dimensionless form for the Striebeck curve (µ friction coefficient - sliding speed v). The friction may damp a vibratory movement or can maintain it (self-vibration), depending on the µ with v (it can increase / decrease or it can be relative constant). The solutions of differential equation of movement are obtained for some work condition of one damper for automatic washing machine. The friction force can transfer partial or total energy or generates excitation energy in damper. The damping efficiency is defined and is determined analytical for the constant friction coefficient and for the parabolic friction coefficient.

  3. Optimal design of a vehicle magnetorheological damper considering the damping force and dynamic range

    International Nuclear Information System (INIS)

    Nguyen, Quoc-Hung; Choi, Seung-Bok

    2009-01-01

    This paper presents an optimal design of a passenger vehicle magnetorheological (MR) damper based on finite element analysis. The MR damper is constrained in a specific volume and the optimization problem identifies the geometric dimensions of the damper that minimize an objective function. The objective function consists of the damping force, the dynamic range, and the inductive time constant of the damper. After describing the configuration of the MR damper, the damping force and dynamic range are obtained on the basis of the Bingham model of an MR fluid. Then, the control energy (power consumption of the damper coil) and the inductive time constant are derived. The objective function for the optimization problem is determined based on the solution of the magnetic circuit of the initial damper. Subsequently, the optimization procedure, using a golden-section algorithm and a local quadratic fitting technique, is constructed via commercial finite element method parametric design language. Using the developed optimization tool, optimal solutions of the MR damper, which are constrained in a specific cylindrical volume defined by its radius and height, are determined and a comparative work on damping force and inductive time constant between the initial and optimal design is undertaken

  4. Supporting brace sizing in structures with added linear viscous fluid dampers: A filter design solution

    OpenAIRE

    Londono, J.M.; Wagg, D.; Neild, S.A.

    2014-01-01

    Viscous fluid dampers have proved to be effective in suppressing unwanted vibrations in a range of engineering structures. When dampers are fitted in a structure, a brace is typically used to attach them to the main structure. The stiffness of this brace can significantly alter the effectiveness of the damper, and in structures with multiple dampers, this can be a complex scenario to model. In this paper, we demonstrate that the effects of the brace compliance on the damper performance can be...

  5. A novel model of magnetorheological damper with hysteresis division

    Science.gov (United States)

    Yu, Jianqiang; Dong, Xiaomin; Zhang, Zonglun

    2017-10-01

    Due to the complex nonlinearity of magnetorheological (MR) behavior, the modeling of MR dampers is a challenge. A simple and effective model of MR damper remains a work in progress. A novel model of MR damper is proposed with force-velocity hysteresis division method in this study. A typical hysteresis loop of MR damper can be simply divided into two novel curves with the division idea. One is the backbone curve and the other is the branch curve. The exponential-family functions which capturing the characteristics of the two curves can simplify the model and improve the identification efficiency. To illustrate and validate the novel phenomenological model with hysteresis division idea, a dual-end MR damper is designed and tested. Based on the experimental data, the characteristics of the novel curves are investigated. To simplify the parameters identification and obtain the reversibility, the maximum force part, the non-dimensional backbone part and the non-dimensional branch part are derived from the two curves. The maximum force part and the non-dimensional part are in multiplication type add-rule. The maximum force part is dependent on the current and maximum velocity. The non-dominated sorting genetic algorithm II (NSGA II) based on the design of experiments (DOE) is employed to identify the parameters of the normalized shape functions. Comparative analysis is conducted based on the identification results. The analysis shows that the novel model with few identification parameters has higher accuracy and better predictive ability.

  6. Experimental Investigation of a Base Isolation System Incorporating MR Dampers with the High-Order Single Step Control Algorithm

    Directory of Open Access Journals (Sweden)

    Weiqing Fu

    2017-03-01

    Full Text Available The conventional isolation structure with rubber bearings exhibits large deformation characteristics when subjected to infrequent earthquakes, which may lead to failure of the isolation layer. Although passive dampers can be used to reduce the layer displacement, the layer deformation and superstructure acceleration responses will increase in cases of fortification earthquakes or frequently occurring earthquakes. In addition to secondary damages and loss of life, such excessive displacement results in damages to the facilities in the structure. In order to overcome these shortcomings, this paper presents a structural vibration control system where the base isolation system is composed of rubber bearings with magnetorheological (MR damper and are regulated using the innovative control strategy. The high-order single-step algorithm with continuity and switch control strategies are applied to the control system. Shaking table test results under various earthquake conditions indicate that the proposed isolation method, compared with passive isolation technique, can effectively suppress earthquake responses for acceleration of superstructure and deformation within the isolation layer. As a result, this structural control method exhibits excellent performance, such as fast computation, generic real-time control, acceleration reduction and high seismic energy dissipation etc. The relative merits of the continuity and switch control strategies are also compared and discussed.

  7. Nonlinear Dynamics Analysis of the Semiactive Suspension System with Magneto-Rheological Damper

    Directory of Open Access Journals (Sweden)

    Hailong Zhang

    2015-01-01

    Full Text Available This paper examines dynamical behavior of a nonlinear oscillator which models a quarter-car forced by the road profile. The magneto-rheological (MR suspension system has been established, by employing the modified Bouc-Wen force-velocity (F-v model of magneto-rheological damper (MRD. The possibility of chaotic motions in MR suspension is discovered by employing the method of nonlinear stability analysis. With the bifurcation diagrams and corresponding Lyapunov exponent (LE spectrum diagrams detected through numerical calculation, we can observe the complex dynamical behaviors and oscillating mechanism of alternating periodic oscillations, quasiperiodic oscillations, and chaotic oscillations with different profiles of road excitation, as well as the dynamical evolutions to chaos through period-doubling bifurcations, saddle-node bifurcations, and reverse period-doubling bifurcations.

  8. Programmable high power beam damper for the Tevatron

    International Nuclear Information System (INIS)

    Crisp, J.; Goodwin, R.; Gerig, R.

    1985-06-01

    A bunch-by-bunch beam damper has been developed for the Fermilab Tevatron. The system reduces betatron oscillation amplitudes and incorporates some useful machine diagnostics. The device is programmable via look-up tables so the output is an arbitrary function, on a bunch-by-bunch basis, of the beam displacement. We are presently using this feature to measure the betatron tune throughout the acceleration cycle. 4 refs

  9. Nonlinear Model of Pseudoelastic Shape Memory Alloy Damper Considering Residual Martensite Strain Effect

    Directory of Open Access Journals (Sweden)

    Y. M. Parulekar

    2012-01-01

    Full Text Available Recently, there has been increasing interest in using superelastic shape memory alloys for applications in seismic resistant-design. Shape memory alloys (SMAs have a unique property by which they can recover their original shape after experiencing large strains up to 8% either by heating (shape memory effect or removing stress (pseudoelastic effect. Many simplified shape memory alloy models are suggested in the past literature for capturing the pseudoelastic response of SMAs in passive vibration control of structures. Most of these models do not consider the cyclic effects of SMA's and resulting residual martensite deformation. Therefore, a suitable constitutive model of shape memory alloy damper which represents the nonlinear hysterical dynamic system appropriately is essential. In this paper a multilinear hysteretic model incorporating residual martensite strain effect of pseudoelastic shape memory alloy damper is developed and experimentally validated using SMA wire, based damper device. A sensitivity analysis is done using the proposed model along with three other simplified SMA models. The models are implemented on a steel frame representing an SDOF system and the comparison of seismic response of structure with all the models is made in the numerical study.

  10. Damping of edgewise vibration in wind turbine blades by means of circular liquid dampers

    DEFF Research Database (Denmark)

    Basu, Biswajit; Zhang, Zili; Nielsen, Søren R.K.

    2016-01-01

    centrifugal acceleration. This centrifugal acceleration makes the use of this kind of oscillatory liquid damper feasible with a small mass ratio to effectively suppress edgewise vibrations. A reduced 2-DOF non-linear model is used for tuning the CLCD attached to a rotating wind turbine blade, ignoring......This paper proposes a new type of passive vibration control damper for controlling edgewise vibrations of wind turbine blades. The damper is a variant of the liquid column damper and is termed as a circular liquid column damper (CLCD). Rotating wind turbine blades generally experience a large...... the coupling between the blade and the tower. The performance of the damper is evaluated under various rotational speeds of the rotor. A special case in which the rotational speed is so small that the gravity dominates the motion of the liquid is also investigated. Further, the legitimacy of the decoupled...

  11. Exploring Parallel Algorithms for Volumetric Mass-Spring-Damper Models in CUDA

    DEFF Research Database (Denmark)

    Rasmusson, Allan; Mosegaard, Jesper; Sørensen, Thomas Sangild

    2008-01-01

    ) from Nvidia. This paper investigates multiple implementations of volumetric Mass-Spring-Damper systems in CUDA. The obtained performance is compared to previous implementations utilizing the GPU through the OpenGL graphics API. We find that both performance and optimization strategies differ widely...

  12. Improved Coulomb-Friction Damper

    Science.gov (United States)

    Campbell, G. E.

    1985-01-01

    Equal damping provided on forward and reverse strokes. Improved damper has springs and wedge rings symmetrically placed on both ends of piston wedge, so friction force same in both directions of travel. Unlike conventional automotive shock absorbers, they resemble on outside, both versions require no viscous liquid and operate over wide temperature range.

  13. Hybrid damper with stroke amplification for damping of offshore wind turbines

    DEFF Research Database (Denmark)

    Brodersen, Mark L.; Høgsberg, Jan

    2016-01-01

    tower. The proposed hybrid damper consists of a passive viscous dashpot placed in series with a load cell and an active actuator. By integrated force feedback control of the actuator motion, the associated displacement amplitude over the viscous damper can be increased compared with the passive viscous......The magnitude of tower vibrations of offshore wind turbines is a key design driver for the feasibility of the monopilesupport structure. A novel control concept for the damping of these tower vibrations is proposed, where viscous-type hybrid dampers are installed at the bottom of the wind turbine...... case, hereby significantly increasing the feasibility of viscous dampers acting at the bottom of the wind turbine tower. To avoid drift in the actuator displacement, a filtered time integration of the measured force signal is introduced. Numerical examples demonstrate that the filtered time integration...

  14. Particle Damping with Granular Materials for Multi Degree of Freedom System

    Directory of Open Access Journals (Sweden)

    Masanobu Inoue

    2011-01-01

    Full Text Available A particle damper consists of a bed of granular materials moving in cavities within a multi degree-of-freedom (MDOF structure. This paper deals with the damping effects on forced vibrations of a MDOF structure provided with the vertical particle dampers. In the analysis, the particle bed is assumed to be a single mass, and the collisions between the granules and the cavities are completely inelastic, i.e., all energy dissipation mechanisms are wrapped into zero coefficient of restitution. To predict the particle damping effect, equations of motion are developed in terms of equivalent single degree-of-freedom (SDOF system and damper mass with use made of modal approach. In this report, the periodic vibration model comprising sustained contact on or separation of the damper mass from vibrating structure is developed. A digital model is also formulated to simulate the damped motion of the physical system, taking account of all vibration modes. Numerical and experimental studies are made of the damping performance of plural dampers located at selected positions throughout a 3MDOF system. The experimental results confirm numerical prediction that collision between granules and structures is completely inelastic as the contributing mechanism of damping in the vertical vibration. It is found that particle dampers with properly selected mass ratios and clearances effectively suppress the resonance peaks over a wide frequency range.

  15. Leak testing of bubble-tight dampers using tracer gas techniques

    Energy Technology Data Exchange (ETDEWEB)

    Lagus, P.L. [Lagus Applied Technology, Inc., San Diego, CA (United States); DuBois, L.J. [Commonwealth Edison, Zion, IL (United States); Fleming, K.M. [NCS Corporation, Columbus, OH (United States)] [and others

    1995-02-01

    Recently tracer gas techniques have been applied to the problem of measuring the leakage across an installed bubble-tight damper. A significant advantage of using a tracer gas technique is that quantitative leakage data are obtained under actual operating differential pressure conditions. Another advantage is that leakage data can be obtained using relatively simple test setups that utilize inexpensive materials without the need to tear ducts apart, fabricate expensive blank-off plates, and install test connections. Also, a tracer gas technique can be used to provide an accurate field evaluation of the performance of installed bubble-tight dampers on a periodic basis. Actual leakage flowrates were obtained at Zion Generating Station on four installed bubble-tight dampers using a tracer gas technique. Measured leakage rates ranged from 0.01 CFM to 21 CFM. After adjustment and subsequent retesting, the 21 CFM damper leakage was reduced to a leakage of 3.8 CFM. In light of the current regulatory climate and the interest in Control Room Habitability issues, imprecise estimates of critical air boundary leakage rates--such as through bubble-tight dampers--are not acceptable. These imprecise estimates can skew radioactive dose assessments as well as chemical contaminant exposure calculations. Using a tracer gas technique, the actual leakage rate can be determined. This knowledge eliminates a significant source of uncertainty in both radioactive dose and/or chemical exposure assessments.

  16. Semi-active Control of Shallow Cables with Magnetorheological Dampers under Harmonic Axial Support Motion

    DEFF Research Database (Denmark)

    Zhou, Q.; Nielsen, Søren R.K.; Qu, W.L.

    2007-01-01

    amplitude is located in a certain range for the case OE2o1/3, the original zero out-of-plane vibration of the cable should be changed to the stable in-plane and out-of-plane coupled oscillation by using the optimal passive viscous damper or the MR damper with the SA-1 rule. It is also observed...... to the first in-plane eigenmode of the cable. The numerical results show that the MR damper with the SA-1 rule and the optimal viscous damper perform similarly to mitigate the vibration of the cable under axial periodic support motion, and, in some cases, the SA-2 rule is more favourable in suppressing...... the cable vibration compared with the SA-1 rule. In the final analysis, both the MR damper and the viscous damper can effectively mitigate the out-of-plane component of the cable, while having little effect on the reduction of the in-plane response in most cases. Furthermore, when the support motion...

  17. A new neuro-fuzzy training algorithm for identifying dynamic characteristics of smart dampers

    International Nuclear Information System (INIS)

    Nguyen, Sy Dzung; Choi, Seung-Bok

    2012-01-01

    This paper proposes a new algorithm, named establishing neuro-fuzzy system (ENFS), to identify dynamic characteristics of smart dampers such as magnetorheological (MR) and electrorheological (ER) dampers. In the ENFS, data clustering is performed based on the proposed algorithm named partitioning data space (PDS). Firstly, the PDS builds data clusters in joint input–output data space with appropriate constraints. The role of these constraints is to create reasonable data distribution in clusters. The ENFS then uses these clusters to perform the following tasks. Firstly, the fuzzy sets expressing characteristics of data clusters are established. The structure of the fuzzy sets is adjusted to be suitable for features of the data set. Secondly, an appropriate structure of neuro-fuzzy (NF) expressed by an optimal number of labeled data clusters and the fuzzy-set groups is determined. After the ENFS is introduced, its effectiveness is evaluated by a prediction-error-comparative work between the proposed method and some other methods in identifying numerical data sets such as ‘daily data of stock A’, or in identifying a function. The ENFS is then applied to identify damping force characteristics of the smart dampers. In order to evaluate the effectiveness of the ENFS in identifying the damping forces of the smart dampers, the prediction errors are presented by comparing with experimental results. (paper)

  18. A new neuro-fuzzy training algorithm for identifying dynamic characteristics of smart dampers

    Science.gov (United States)

    Dzung Nguyen, Sy; Choi, Seung-Bok

    2012-08-01

    This paper proposes a new algorithm, named establishing neuro-fuzzy system (ENFS), to identify dynamic characteristics of smart dampers such as magnetorheological (MR) and electrorheological (ER) dampers. In the ENFS, data clustering is performed based on the proposed algorithm named partitioning data space (PDS). Firstly, the PDS builds data clusters in joint input-output data space with appropriate constraints. The role of these constraints is to create reasonable data distribution in clusters. The ENFS then uses these clusters to perform the following tasks. Firstly, the fuzzy sets expressing characteristics of data clusters are established. The structure of the fuzzy sets is adjusted to be suitable for features of the data set. Secondly, an appropriate structure of neuro-fuzzy (NF) expressed by an optimal number of labeled data clusters and the fuzzy-set groups is determined. After the ENFS is introduced, its effectiveness is evaluated by a prediction-error-comparative work between the proposed method and some other methods in identifying numerical data sets such as ‘daily data of stock A’, or in identifying a function. The ENFS is then applied to identify damping force characteristics of the smart dampers. In order to evaluate the effectiveness of the ENFS in identifying the damping forces of the smart dampers, the prediction errors are presented by comparing with experimental results.

  19. A broadband damper design inspired by cartilage-like relaxation mechanisms

    Science.gov (United States)

    Liu, Lejie; Usta, Ahmet D.; Eriten, Melih

    2017-10-01

    In this study, we introduce a broadband damper design inspired by the cartilage-like relaxation mechanisms. In particular, we study broadband (static to 10 kHz) dissipative properties of model cartilage systems by probe-based static and dynamic indentation, and validate that fractional Zener models can simulate the empirical data up to a desirable accuracy within the frequency range of interest. Utilizing these observations, we design a composite damper design where a poroelastic layer is sandwiched between two hard materials, and load transfer occurs across interfaces with multiple length scales. Modeling those interfaces with fractional Zener elements in parallel configuration, and manipulating the distribution of the Zener elements across different peak relaxation frequencies, we obtain a relatively constant loss factor within an unprecedented frequency range (3-3 kHz). We also discuss how these findings can be employed in a practical damping design.

  20. Velocity & displacement-dependent damper: A novel passive shock absorber inspired by the semi-active control

    Science.gov (United States)

    Nie, Shida; Zhuang, Ye; Wang, Yong; Guo, Konghui

    2018-01-01

    The performance of velocity & displacement-dependent damper (VDD), inspired by the semi-active control, is analyzed. The main differences among passive, displacement-dependent and semi-active dampers are compared on their damping properties. Valve assemblies of VDD are modelled to get an insight into its working principle. The mechanical structure composed by four valve assemblies helps to enable VDD to approach the performance by those semi-active control dampers. The valve structure parameters are determined by the suggested two-step process. Hydraulic model of the damper is built with AMEsim. Simulation result of F-V curves, which is similar to those of semi-active control damper, demonstrates that VDD could achieve the similar performance of semi-active control damper. The performance of a quarter vehicle model employing VDD is analyzed and compared with semi-active suspension. Simulation results show that VDD could perform as good as a semi-active control damper. In addition, no add-on hardware or energy consumption is needed for VDD to achieve the remarkable performance.

  1. High-Temperature Vibration Damper

    Science.gov (United States)

    Clarke, Alan; Litwin, Joel; Krauss, Harold

    1987-01-01

    Device for damping vibrations functions at temperatures up to 400 degrees F. Dampens vibrational torque loads as high as 1,000 lb-in. but compact enough to be part of helicopter rotor hub. Rotary damper absorbs energy from vibrating rod, dissipating it in turbulent motion of viscous hydraulic fluid forced by moving vanes through small orifices.

  2. Shallow Water Tuned Liquid Dampers

    DEFF Research Database (Denmark)

    Krabbenhøft, Jørgen

    that for realistic roughness parameters the bottom friction has very limited effect on the liquid sloshing behavior and can be neglected. Herby the postulate is verified. Based on the mathematical model three dimensionless parameters are derived showing that the response of the damper depends solely on ratio......The use of sloshing liquid as a passive means of suppressing the rolling motion of ships was proposed already in the late 19th century. Some hundred years later the use of liquid sloshing devices, often termed Tuned Liquid Dampers (TLD), began to find use in the civil engineering community....... The TLDs studied in this thesis essentially consist of a rectangular container partially filled with liquid in the form of plain tap water. The frequency of the liquid sloshing motion, which is adjusted by varying the length of the tank and the depth of the wa- ter, is tuned to the structural frequency...

  3. Investigation on the Cyclic Response of Superelastic Shape Memory Alloy (SMA Slit Damper Devices Simulated by Quasi-Static Finite Element (FE Analyses

    Directory of Open Access Journals (Sweden)

    Jong Wan Hu

    2014-02-01

    Full Text Available In this paper, the superelastic shape memory alloy (SMA slit damper system as an alternative design approach for steel structures is intended to be evaluated with respect to inelastic behavior simulated by refined finite element (FE analyses. Although the steel slit dampers conventionally used for aseismic design are able to dissipate a considerable amount of energy generated by the plastic yielding of the base materials, large permanent deformation may occur in the entire structure. After strong seismic events, extra damage repair costs are required to restore the original configuration and to replace defective devices with new ones. Innovative slit dampers fabricated by superelastic SMAs that automatically recover their initial conditions only by the removal of stresses without heat treatment are introduced with a view toward mitigating the problem of permanent deformation. The cyclically tested FE models are calibrated to experimental results for the purpose of predicting accurate behavior. This study also focuses on the material constitutive model that is able to reproduce the inherent behavior of superelastic SMA materials by taking phase transformation between austenite and martensite into consideration. The responses of SMA slit dampers are compared to those of steel slit dampers. Axial stress and strain components are also investigated on the FE models under cyclic loading in an effort to validate the adequacy of FE modeling and then to compare between two slit damper systems. It can be shown that SMA slit dampers exhibit many structural advantages in terms of ultimate strength, moderate energy dissipation and recentering capability.

  4. Active tuned mass damper for damping of offshore wind turbine vibrations

    DEFF Research Database (Denmark)

    Brodersen, Mark Laier; Bjørke, Ann-Sofie; Høgsberg, Jan Becker

    2017-01-01

    An active tuned mass damper (ATMD) is employed for damping of tower vibrations of fixed offshore wind turbines, where the additional actuator force is controlled using feedback from the tower displacement and the relative velocity of the damper mass. An optimum tuning procedure equivalent to the ...

  5. Earthquake response of adjacent structures with viscoelastic and friction dampers

    Directory of Open Access Journals (Sweden)

    Žigić Miodrag

    2015-01-01

    Full Text Available We study the seismic response of two adjacent structures connected with a dry friction damper. Each of them consists of a viscoelastic rod and a rigid block, which can slide without friction along the moving base. A simplified earthquake model is used for modeling the horizontal ground motion. Energy dissipation is taken by the presence of the friction damper, which is modeled by the set-valued Coulomb friction law. Deformation of viscoelastic rods during the relative motion of the blocks represents another way of energy dissipation. The constitutive equation of a viscoelastic body is described by the fractional Zener model, which includes fractional derivatives of stress and strain. The problem merges fractional derivatives as non-local operators and theory of set-valued functions as the non-smooth ones. Dynamical behaviour of the problem is governed by a pair of coupled multi-valued differential equations. The posed Cauchy problem is solved by use of the Grünwald-Letnikov numerical scheme. The behaviour of the system is analyzed for different values of system parameters.

  6. On the assessment of a tunable auxiliary mass damper with a friction damper in its suspension: numerical study

    Directory of Open Access Journals (Sweden)

    Guerineau E.L.C.

    2016-01-01

    Full Text Available Auxiliary Mass Damper‘s (AMD performance is susceptible to changes in the frequency or in the excitation force’s nature. Therefore, to improve the robustness of the AMD it’s necessary to design new systems which are tunable and that could be used over large frequency range. In this work a friction damper, which is an association in series of a spring and a scratcher, is used to tune the AMD at the same time it dissipates the mechanical energy of the principal mass by changing the normal force on the scratcher. Three normal force control strategies, and two combinations of them, are studied: i The normal force is assumed constant; ii The normal force is obtained from the solution of the equation of motion assuming null displacement for the principal mass; iii The normal force is obtained based on the vibratory system’s state variables condition, guarantying that the direction of the friction force promotes the movement of the principal mass toward its static equilibrium position. The effectiveness of the proposed tunable AMD, where the adaptability is obtained by controlling the normal force on the smart friction damper, is evaluated based on mass and frequency ratios variations for each strategy.

  7. A nonlinear auxetic structural vibration damper with metal rubber particles

    International Nuclear Information System (INIS)

    Ma, Yanhong; Zhang, Dayi; Zhu, Bin; Chen, Lulu; Hong, Jie; Scarpa, Fabrizio

    2013-01-01

    The work describes the mechanical performance of a metal rubber particles (MRP) damper design based on an auxetic (negative Poisson’s ratio) cellular configuration. The auxetic damper configuration is constituted by an anti-tetrachiral honeycomb, where the cylinders are filled with the MRP material. The MRP samples have been subjected to quasi-static loading to measure the stiffness and loss factor from the static hysteresis curve. A parametric experimental analysis has been carried out to investigate the effect of relative density and filling percentage on the static performance of the MRP, and to identify design guidelines for best use of MRP devices. An experimental assessment of the integrated auxetic-MRP damper concept has been provided through static and dynamic force response techniques. (paper)

  8. A numerical investigation into the effect of windvent dampers on operating conditions

    Energy Technology Data Exchange (ETDEWEB)

    Hughes, Ben Richard; Abdul Ghani, S.A.A. [Faculty of Arts, Computing, Engineering and Sciences, Materials and Engineering Institute, Sheffield Hallam University, Sheffield, South Yorkshire S1 1WB (United Kingdom)

    2009-02-15

    The United Kingdom has made a commitment to reduce buildings carbon emissions, placing a greater onus on sustainable energy sources. Therefore, an anticipated increase of usage of zero carbon technologies in new and existing building has led to the emergence of passive ventilation devices as an alternative to mechanical ventilation and air conditioning. The windvent is a commercially available passive ventilation device. The device is constructed from sheet metal and works on the principle of pressure differential. Whereby air rises, creating a low pressure in the receiving room, which then draws in the fresh air. The ensuing air delivery velocity is controlled by the dampers, installed at the room entry interface. The dampers are actuator operated, and form the basis of the control system for the device. The purpose of this paper is to investigate the control mechanism for the device and ascertain an optimum operating range. Numerical analysis is carried out using a commercial computational fluid dynamics (CFD) code, to investigate the effect of various damper angles (range 0-90 ). The results show that optimum operating occurs at a damper angle range of 45-55 , at the UK average 4.5 m/s external wind speed. The operating range when considered in tandem with macro climatic influences is central to determining the overall control strategy for the fresh air supply. The results provide useful information for both engineers and architects when examining ways to reduce new and existing buildings running costs, and conform to new legislation. (author)

  9. Contributions to modeling functionality of a high frequency damper system

    Science.gov (United States)

    Sirbu, E. A.; Horga, S.; Vrabioiu, G.

    2016-08-01

    Due to the necessity of improving the handling performances of a motor vehicle, it is imperative to understand the suspensions properties that affects ride and directional respons.The construction of a fero-magnetic shock absorber is based on two bellows interconnected by a pipe-line. Through this pipe-line the fero-magnetic fluid is carried between the two bellows. The damping characteristic of the shock absorber is affected by the viscosity of the fero-magnetic fluid. The viscosity of the fluid, is controlled through a electric coil mounted on the bellows connecting pipe-line. Modifying the electrical field of the coil, the viscosity of the fluid will change, finally affecting the damping characteristic of the shock absorber. A recent system called „CCD Pothole Suspension” is implemented on Ford vehicles. By modifying the dampning characteristic of the shock absorbers, vehicle daynamics can be improved; also the risk of damaging the suspension will be decreased. The approach of this paper is to analyze the behaviour of the fero magnetic damper, thus determining how it will affect the performances of the vehicle suspensions. The experimental research will provide a better understanding of the behavior of the fero-magnetic shock absorber, and the possible advantages of using this system.

  10. A novel two-way-controllable magneto-rheological fluid damper

    International Nuclear Information System (INIS)

    Aydar, Gokhan; Wang, Xiaojie; Gordaninejad, Faramarz

    2010-01-01

    In this paper, a disc type, radial flow-mode magneto-rheological (MR) fluid damper comprising a permanent magnet and an electromagnet is designed, built and tested. The proposed MR fluid damper has an MR valve with which two-way controllability through cancellation or enhancement of the magnetic field is obtained. This added feature provides damping forces less than or greater than that of a passive viscous original equipment manufacturer damper. A three-dimensional electromagnetic finite element analysis has been performed to realize this unique function in the proposed design. Experimental and theoretical studies have been conducted in order to demonstrate that this new design can provide softer damping properties by cancelling the effect of the permanent magnet, while at the same time enhancing the field effect, resulting in a harder damping device. Softer and harder damping refer to decrease and increase in the damping, respectively

  11. LHC Damper Beam commissioning in 2010

    CERN Document Server

    Höfle, W; Schokker, M; Valuch, D

    2011-01-01

    The LHC transverse dampers were commissioned in 2010 with beam and their use at injection energy of 450 GeV, during the ramp and in collisions at 3.5 TeV for Physics has become part of the standard operations pro- cedure. The system proved important to limit emittance blow-up at injection and to maintain smaller than nominal emittances throughout the accelerating cycle. We describe the commissioning of the system step-by-step as done in 2010 and summarize its performance as achieved for pro- ton as well as ion beams in 2010. Although its principle function is to keep transverse oscillations under control, the system has also been used as an exciter for abort gap clean- ing and tune measurement. The dedicated beam position measurement system with its low noise properties provides additional possibilities for diagnostics.

  12. Modelling the nonlinear behaviour of an underplatform damper test rig for turbine applications

    Science.gov (United States)

    Pesaresi, L.; Salles, L.; Jones, A.; Green, J. S.; Schwingshackl, C. W.

    2017-02-01

    Underplatform dampers (UPD) are commonly used in aircraft engines to mitigate the risk of high-cycle fatigue failure of turbine blades. The energy dissipated at the friction contact interface of the damper reduces the vibration amplitude significantly, and the couplings of the blades can also lead to significant shifts of the resonance frequencies of the bladed disk. The highly nonlinear behaviour of bladed discs constrained by UPDs requires an advanced modelling approach to ensure that the correct damper geometry is selected during the design of the turbine, and that no unexpected resonance frequencies and amplitudes will occur in operation. Approaches based on an explicit model of the damper in combination with multi-harmonic balance solvers have emerged as a promising way to predict the nonlinear behaviour of UPDs correctly, however rigorous experimental validations are required before approaches of this type can be used with confidence. In this study, a nonlinear analysis based on an updated explicit damper model having different levels of detail is performed, and the results are evaluated against a newly-developed UPD test rig. Detailed linear finite element models are used as input for the nonlinear analysis, allowing the inclusion of damper flexibility and inertia effects. The nonlinear friction interface between the blades and the damper is described with a dense grid of 3D friction contact elements which allow accurate capturing of the underlying nonlinear mechanism that drives the global nonlinear behaviour. The introduced explicit damper model showed a great dependence on the correct contact pressure distribution. The use of an accurate, measurement based, distribution, better matched the nonlinear dynamic behaviour of the test rig. Good agreement with the measured frequency response data could only be reached when the zero harmonic term (constant term) was included in the multi-harmonic expansion of the nonlinear problem, highlighting its importance

  13. Theoretical and experimental investigation of position-controlled semi-active friction damper for seismic structures

    Science.gov (United States)

    Lu, Lyan-Ywan; Lin, Tzu-Kang; Jheng, Rong-Jie; Wu, Hsin-Hsien

    2018-01-01

    A semi-active friction damper (SAFD) can be employed for the seismic protection of structural systems. The effectiveness of an SAFD in absorbing seismic energy is usually superior to that of its passive counterpart, since its slip force can be altered in real time according to structural response and excitation. Most existing SAFDs are controlled by adjusting the clamping force applied on the friction interface. Thus, the implementation of SAFDs in practice requires precision control of the clamping force, which is usually substantially larger than the slip force. This may increase the implementation complexity and cost of SAFDs. To avoid this problem, this study proposes a novel position-controlled SAFD, named the leverage-type controllable friction damper (LCFD). The LCFD system combines a traditional passive friction damper and a leverage mechanism with a movable central pivot. By simply controlling the pivot position, the damping force generated by the LCFD system can be adjusted in real time. In order to verify the feasibility of the proposed SAFD, a prototype LCFD was tested by using a shaking table. The test results demonstrate that the equivalent friction force and hysteresis loop of the LCFD can be regulated by controlling the pivot position. By considering 16 ground motions with two different intensities, the adaptive feature of the LCFD for seismic structural control is further demonstrated numerically.

  14. Semi-active Control of Magneto-Rheological Dampers with Negative Stiffness

    DEFF Research Database (Denmark)

    Bhowmik, Subrata

    2009-01-01

    performance by introduction of apparent negative damper stiffness. The design of the control strategy aims at maximizing the damping ratio of the critical mode of the structure. Explicit solutions for the complex valued natural frequency of the damped structure and the associated damping ratio are obtained...... sufficiently accurate. This is done by letting the desired force be the input to an inverse Bingham model, which provides the corresponding desired voltage level of the MR damper. Numerical simulations are conducted to demonstrate the performance of the proposed semi-active control strategy with apparent......Effective damping of large and flexible structures by semi-active dampers relies greatly on the control strategy applied, which should combine the robustness of passive devices and the increased damping performance often available from active control. For structural control the Magneto...

  15. Mechanical design handbook for elastomers. [the design of elastomer dampers for application in rotating machinery

    Science.gov (United States)

    Darlow, M.; Zorzi, E.

    1981-01-01

    A comprehensive guide for the design of elastomer dampers for application in rotating machinery is presented. Theoretical discussions, a step by step procedure for the design of elastomer dampers, and detailed examples of actual elastomer damper applications are included. Dynamic and general physical properties of elastomers are discussed along with measurement techniques.

  16. Investigation on vibrational dampers for cables of Tsurumi Tsubasa bridge; Tsurumi tsubasabashi no keburu seishin hoshiki ni kansuru jisho

    Energy Technology Data Exchange (ETDEWEB)

    Takano, H.; Ogasawara, M.; Shimosato, T. [Metropolitan Public Corp., Tokyo (Japan); Yamada, H. [Yokohama National Univ. (Japan)] Murakami, T. [NKK Corp., Tokyo (Japan). Applied Technology Research Center

    1998-03-20

    In a long cable-stayed bridge, countermeasure against wind induced vibration should be often taken at the same time together with the measure against angular bent phenomena (phenomena in which secondary bending stress is generated on the front of fixing socket by live load). The conventional countermeasure is a combined use of buffer rubber and dampers. This study points out problems in the conventional countermeasure on the application to the cables of the Tsurumi Tsubasa Bridge and combination of dampers and angular bending buffer device is examined. The result shows that a combined use of high-damping rubber and oil dampers enables installation of the dampers in a lower position while maintaining the performance and is excellent in the easiness in installation and maintenance and in aesthetic view. This system was applied to the Tsurumi Tsubasa Bridge and the effectiveness on damping and angular bending relaxation was confirmed through the model tests, and vibration tests and field observation on the cables. 9 refs., 20 figs., 7 tabs.

  17. A hysteretic model considering Stribeck effect for small-scale magnetorheological damper

    Science.gov (United States)

    Zhao, Yu-Liang; Xu, Zhao-Dong

    2018-06-01

    Magnetorheological (MR) damper is an ideal semi-active control device for vibration suppression. The mechanical properties of this type of devices show strong nonlinear characteristics, especially the performance of the small-scale dampers. Therefore, developing an ideal model that can accurately describe the nonlinearity of such device is crucial to control design. In this paper, the dynamic characteristics of a small-scale MR damper developed by our research group is tested, and the Stribeck effect is observed in the low velocity region. Then, an improved model based on sigmoid model is proposed to describe this Stribeck effect observed in the experiment. After that, the parameters of this model are identified by genetic algorithms, and the mathematical relationship between these parameters and the input current, excitation frequency and amplitude is regressed. Finally, the predicted forces of the proposed model are validated with the experimental data. The results show that this model can well predict the mechanical properties of the small-scale damper, especially the Stribeck effect in the low velocity region.

  18. Passivity enhancement by series LC filtered active damper with zero current reference

    DEFF Research Database (Denmark)

    Bai, Haofeng; Wang, Xiongfei; Blaabjerg, Frede

    2016-01-01

    can be improved by enhancing the passivity of the total admittance seen by the grid, which allows for a zero current reference and a much simpler current controller for the active damper. To show the performance of the active damper with zero reference, this paper first carries out the impedance based...... stability analysis of grid converters in the weak grid. Based on the impedance model of the series LC filtered active damper, the real part of its output admittance is investigated and shown to be able to enhance the passivity of the admittance of the converters seen by the grid. Finally, simulation...

  19. ANTHROPOMETRIC CHARACTERISTICS OF FLIGHT PERSONNEL FOR DESIGNING DAMPERS FOR SHOCKPROOF SEATS OF HELICOPTER CREWS.

    Science.gov (United States)

    Moiseev, Yu B; Ignatovich, S N; Strakhov, A Yu

    The article discusses anthropometric design of shockproof pilot seats for state-of-the-art helicopters. Object of the investigation was anthropometric parameters of the helicopter aviation personnel of the Russian interior troops. It was stated that the body parameters essential for designing helicopter seat dampers are mass of the body part that presses against the seat in the seating position, and eye level above the seat surface. An uncontrolled seat damper ensuring shockproof safety to 95 % helicopter crews must be designed for the body mass contacting the seat of 99.7 kg and eye level above the seat of 78.6 cm. To absorb.shock effectively, future dampers should be adjustable to pilot's body parameters. The optimal approach to anthropometric design of a helicopter seat is development of type pilot' body models with due account of pilot's the flight outfit and seat geometry. Principle criteria of type models are body mass and eye level. The authors propose a system of type body models facilitating specification of anthropometric data helicopter seat developers.

  20. Comparison of the Efficiency of Tuned Mass and Tuned Liquid Dampers at High-Rise Structures under Near and Far Fault Earthquakes

    Directory of Open Access Journals (Sweden)

    Hamed Rahman Shokrgozar

    2017-02-01

    Full Text Available Tuned mass and tuned liquid dampers are most common passive control systems that used for decrease of seismic responses of buildings. In this study, the performance of high-rise buildings with TM and TL dampers are evaluated under seven near-fault and seven far-fault earthquakes. For this purpose, a twenty-four stories steel moment frame building has been considered and the time history dynamic analyses are performed for both of controlled and uncontrolled states. Moreover, this building has been also modelled with five various mass, stiffness and damping ratios.The results have been shown that decreasing the structural responses at tall buildings against near-fault earthquakes are more than far-fault earthquakes due to the effect of higher modes. Furthermore, the tuned mass damper has better performance at decreasing of the responses in comparison of tuned liquid dampers.

  1. Digital radiology and digitally formatted image management systems

    International Nuclear Information System (INIS)

    Cox, G.G.; Dwyer, S.J. III; Templeton, A.W.

    1987-01-01

    The number of diagnostic examinations performed with digitally formatted imaging equipment is increasing. Digital general-purpose and fluoroscopic radiology systems are being clinically evaluated. Digitizing conventional x-ray films, such as mammograms, frequently improves the diagnostic quality of the images. The digitizing process with laser has also afforded the opportunity to document required spatial resolution for digital imaging and network systems. The use of digitally formatted image instrumentation imposes new requirements on the acquisition, display and manipulation, transmission, hard copy image recording, and archiving of diagnostic data. Networking of digitally formatted image data offers many advantages for managing digital information. This paper identifies and describes digital radiographic systems. Parameters required for designing and implementing a digital image management system are outlined. Spatial and contrast resolution requirements are identified. The key parameters include the amount of image data generated each working day, the retrieval rate of the generated data, the display hardware and software needed for interactive diagnosis display stations, the requirements for analog hard copy generation, and on-line and long-term archiving requirements. These image management systems are often called PACS (Picture Archiving and Communication Systems)

  2. Dynamic analysis of electro- and magneto-rheological fluid dampers using duct flow models

    International Nuclear Information System (INIS)

    Esteki, Kambiz; Bagchi, Ashutosh; Sedaghati, Ramin

    2014-01-01

    Magneto-rheological (MR) and electro-rheological (ER) fluid dampers provide a semi-active control mechanism for suppressing vibration responses of a structure. MR and ER fluids change their viscosity under the influence of magnetic and electrical fields, respectively, which facilitates automatic control when these fluids are used in damping devices. The existing models, namely the phenomenological models for simulating the behavior of MR and ER dampers, rely on various parameters determined experimentally by the manufacturers for each damper configuration. It is of interest to develop mechanistic models of these dampers which can be applied to various configurations so that their fundamental characteristics can be studied to develop flexible design solutions for smart structures. This paper presents a formulation for dynamic analysis of electro-rheological (ER) and magneto-rheological (MR) fluid dampers in flow and mix mode configurations under harmonic and random excitations. The procedure employs the vorticity transport equation and the regularization function to deal with the unsteady flow and nonlinear behavior of ER/MR fluid in general motion. The finite difference method has been used to solve the governing differential equations. Using the developed approach, the damping force of ER/MR dampers can be calculated under any type of excitation. (paper)

  3. Evaluation of the Reduction of Seismic Response of Adjacent Structures Using Viscous Damper Joint

    Directory of Open Access Journals (Sweden)

    Hamed Karbalay Malek

    2017-09-01

    Full Text Available This study examines the effect of common viscose damper on the behavior of adjacent reinforced concrete structures. For this purpose, three reinforced concrete 3, 5 and 7 floors buildings with a regular plan were selected and were compared in two cases without and with viscous dampers at the seams. They are designed based on discussions of Buildings Regulations 2800 and the 6 and 9 issues of Iranian National Building Regulations. Those buildings face under accelerograms of Bam, Mangil and El Centro, and then they are analyzed with nonlinear modal time history. This Accelerograms before applying to the structures, they are scaled based on the 2800 Regulations. Those buildings were modeled by SAP2000 finite element modeling software. Linear behavior of structural components of the structure and the non-linear behavior viscous damper were modeled. Finally, the seismic response of buildings includes the base shear force, up to a maximum lateral acceleration of seismic classes and classes for both with and without the viscous damper have been extracted and compared. The results showed the reduction in relative lateral displacement, maximum acceleration and base cut applied to structure in the presence of viscous dampers between two structures. This decline is not even in the direction that the viscous damper is viewed as significant.

  4. Durability test and simulation with integration of mechatronical systems. Examplified by a variable damper; Mechatronische Systeme bei der Betriebsfestigkeitspruefung und -simulation am Beispiel eines variablen Daempfers

    Energy Technology Data Exchange (ETDEWEB)

    Brune, M.; Poetter, K. [BMW Group, Muenchen (Germany). Fachbereich Betriebsfestigkeit und Werkstoffe

    2008-07-01

    The use of mechatronical devices in car-design is of growing importance. The purpose of these control systems is to improve driving dynamics and comfort. As an example the roll-stabilisation and the variable damper can be mentioned. Both systems influence the component stress of suspension and chassis parts. Therefore they have to be integrated in numeric- and experimental fatigue analysis. On the basis of examples, this paper describes current methods of resolution and future challenges.

  5. Neural Network modeling of forward and inverse behavior of rotary MR damper

    DEFF Research Database (Denmark)

    Bhowmik, Subrata; Høgsberg, Jan Becker; Weber, Felix

    2010-01-01

    of nonlinear problems. The present paper concerns the nonparametric neural network modeling of the dynamic behavior of a rotary MR damper. A rotary type MR damper consists of a rotating disk which is enclosed in a metallic housing filled with the MR fluid which is operated in shear mode. The dissipative torque...

  6. Establishment of the technical basis for applying viscous dampers to nuclear power plants

    International Nuclear Information System (INIS)

    Narahara, Yukiko; Higuchi, Tomokazu; Katayama, Hiroshi; Ito, Ryo; Hattori, Kiyoshi; Nakajima, Jun

    2017-01-01

    For the purpose of introducing viscous dampers to nuclear power plants, the damping characteristic of the viscous damper under specific conditions in nuclear power plants was examined. In particular the seismic response analysis method, the design evaluation method, and the maintenance and management guideline were studied. In the viscous dampers characteristic test, the damping characteristics under earthquake motion and the environmental condition of nuclear power plants have been examined. From the test results, if the parameters such as vibration amplitude, vibration frequency, repeated load, temperature, and radiation are considered, there is a possibility of viscous damper application to components in nuclear power plants. In order to evaluate the applicability of the complex modal analysis method using response spectrum, comparison with the time history response analysis result was performed using a PWR steam generator analysis model. The evaluation result from the complex modal analysis method was in good agreement with the time history response analysis result, and the availability of this method was confirmed. From the test results, considerations in design and maintenance in the case of applying viscous dampers to nuclear power plants were selected. The bases of the design evaluation method and the maintenance and management guideline were developed. (author)

  7. Establishment of the technical basis to apply the viscous damper in nuclear power plant

    International Nuclear Information System (INIS)

    Nakajima, J.; Suezono, N.; Higuchi, T.; Katayama, H.

    2014-01-01

    In recent years, the technical development of the damper using viscous fluid (hereinafter called 'the viscous damper') for the structures, bridges and components in the general industrial field is remarkable, and the experiences of the application to mitigate influence in an earthquake is being gathered now. In this paper, purpose of the whole activity, schedule, the research and test results carried out so far, and future plan to establish the technical basis to apply the viscous damper in nuclear power plant are reported. (author)

  8. Establishment of the technical basis to apply the viscous damper in nuclear power plant

    Energy Technology Data Exchange (ETDEWEB)

    Nakajima, J.; Suezono, N.; Higuchi, T. [Toshiba Corp., Isogo Nuclear Engineering Center, Isogo-ku, Yokohama (Japan); Katayama, H. [Toshiba Corp., Power and Industrial Systems Research and Development Center, Isogo-ku, Yokohama (Japan)

    2014-07-01

    In recent years, the technical development of the damper using viscous fluid (hereinafter called 'the viscous damper') for the structures, bridges and components in the general industrial field is remarkable, and the experiences of the application to mitigate influence in an earthquake is being gathered now. In this paper, purpose of the whole activity, schedule, the research and test results carried out so far, and future plan to establish the technical basis to apply the viscous damper in nuclear power plant are reported. (author)

  9. Optimization of location and forces of friction dampers

    Directory of Open Access Journals (Sweden)

    Sergio Pastor Ontiveros-Pérez

    Full Text Available Abstract Damper optimization is a new area which has been investigated in recent years. There are various methods employed in optimization, among which are highlighted the classic and the most recent that are functioning with reliability, efficiency and speed for optimum results. This paper proposes a method for simultaneous optimization of placement and forces of friction dampers using the Firefly Algorithm, which is a recent meta-heuristic algorithm inspired in the behavior of fireflies. Herein, three different optimization objective are presented: i minimize the maximum displacement at the top of the structure; ii minimize the maximum inter-story drift; iii minimize the maximum acceleration at the top of the structure. The three objective functions were evaluated in two civil structures (a nine-story building and a sixteen-story building subjected to two real seismic records. The first seismic record is El Centro, which took place in the southeastern California on the boarder of the United States and Mexico in 1940. The second one is the earthquake that occurred in Caucete, province of San Juan, Argentina, in 1977. The results showed that the proposed method was able to optimize the friction dampers, reducing considerably the response of the structures.

  10. Smart Novel Semi-Active Tuned Mass Damper for Fixed-Bottom and Floating Offshore Wind (Presentation)

    Energy Technology Data Exchange (ETDEWEB)

    Rodriguez Tsouroukdissian, Arturo [Alstom Renewable US LLC

    2016-05-02

    The intention of this paper is to present the results of a novel smart semi-active tuned mass damper (SA-TMD), which mitigates unwanted loads for both fixed-bottom and floating offshore wind systems. (Presentation Format).

  11. MR Damper Controlled Vibration Absorber for Enhanced Mitigation of Harmonic Vibrations

    Directory of Open Access Journals (Sweden)

    Felix Weber

    2016-12-01

    Full Text Available This paper describes a semi-active vibration absorber (SVA concept based on a real-time controlled magnetorheological damper (MR-SVA for the enhanced mitigation of structural vibrations due to harmonic disturbing forces. The force of the MR damper is controlled in real-time to generate the frequency and damping controls according to the behaviour of the undamped vibration absorber for the actual frequency of vibration. As stiffness and damping emulations in semi-active actuators are coupled quantities the control is formulated to prioritize the frequency control by the controlled stiffness. The control algorithm is augmented by a stiffness correction method ensuring precise frequency control when the desired control force is constrained by the semi-active restriction and residual force of the MR damper. The force tracking task is solved by a model-based feed forward with feedback correction. The MR-SVA is numerically and experimentally validated for the primary structure with nominal eigenfrequency and when de-tuning of −10%, −5%, +5% and +10% is present. Both validations demonstrate that the MR-SVA improves the vibration reduction in the primary structure by up to 55% compared to the passive tuned mass damper (TMD. Furthermore, it is shown that the MR-SVA with only 80% of tuned mass leads to approximately the same enhanced performance while the associated increased relative motion amplitude of the tuned mass is more than compensated be the reduced dimensions of the mass. Therefore, the MR-SVA is an appropriate solution for the mitigation of tall buildings where the pendulum mass can be up to several thousands of metric tonnes and space for the pendulum damper is limited.

  12. Studi Respon Seismik Penggunaan Steel Slit Damper (SSD pada Portal Baja

    Directory of Open Access Journals (Sweden)

    Lisa Ika Arumsari

    2012-09-01

    Full Text Available Salah satu metode yang dapat digunakan untuk mengurangi dampak dari beban gempa terhadap portal baja adalah menggunakan peredam. Steel Slit Damper (SSD adalah salah satu jenis peredam yang dibuat dari sejumlah pelat baja lunak berbentuk segi-4 yang dimodelkan sebagai pegas-pegas yang disusun secara seri. Energi akibat gempa disalurkan melalui strip-strip damper yang mudah meleleh ketika perangkat mengalami deformasi inelastis siklik. SSD mendisipasi energi melalui pembentukan sendi plastis atau pelelehan pelat damper. Pada penelitian ini dilakukan analisa respon seismik Steel Slit Damper (SSD pada portal baja 1 lantai yang menerima beban lateral berupa beban gempa, dengan membandingkan portal baja konvensional, portal baja inverted-v, dan portal baja dengan SSD. Hasil analisa menunjukkan bahwa gaya geser, gaya normal, dan momen yang dihasikan portal dengan SSD lebih kecil hingga 80,49% dari gaya-gaya yang dihasilkan portal konvensional, tetapi gaya-gaya tersebut masih lebih besar daripada yang dihasilkan portal inverted-V. Portal dengan SSD dapat memperkecil simpangan sebesar 94,12% pada portal konvensional dan sebesar 33,33% pada portal bracing inverted-v. Hasil penelitian juga menunjukkan bahwa portal SSD memiliki daktilitas 105,85% lebih tinggi dari portal konvensional dan 298,67% lebih tinggi dari portal bracing inverted-v

  13. Bifurcations in the response of a flexible rotor in squeeze-film dampers with retainer springs

    International Nuclear Information System (INIS)

    Inayat-Hussain, Jawaid I.

    2009-01-01

    Squeeze-film dampers are commonly used in conjunction with rolling-element or hydrodynamic bearings in rotating machinery. Although these dampers serve to provide additional damping to the rotor-bearing system, there have however been some cases of rotors mounted in these dampers exhibiting non-linear behaviour. In this paper a numerical study is undertaken to determine the effects of design parameters, i.e., gravity parameter, W, mass ratio, α, and stiffness ratio, K, on the bifurcations in the response of a flexible rotor mounted in squeeze-film dampers with retainer springs. The numerical simulations were undertaken for a range of speed parameter, Ω, between 0.1 and 5.0. Numerical results showed that increasing K causes the onset speed of bifurcation to increase, whilst an increase of α reduces the onset speed of bifurcation. For a specific combination of K and α values, the onset speed of bifurcation appeared to be independent of W. The instability of the rotor response at this onset speed was due to a saddle-node bifurcation for all the parameter values investigated in this work with the exception of the combination of α = 0.1 and K = 0.5, where a secondary Hopf bifurcation was observed. The speed range of non-synchronous response was seen to decrease with the increase of α; in fact non-synchronous rotor response was totally absent for α=0.4. With the exception of the case α = 0.1, the speed range of non-synchronous response was also seen to decrease with the increase of K. Multiple responses of the rotor were observed at certain values of Ω for various combinations of parameters W, α and K, where, depending on the values of the initial conditions the rotor response could be either synchronous or quasi-periodic. The numerical results presented in this work were obtained for an unbalance parameter, U, value of 0.1, which is considered as the upper end of the normal unbalance range of most practical rotor systems. These results provide some insights

  14. A Study on the Modeling of the Oil Damper in an Auto-Door Hinge

    International Nuclear Information System (INIS)

    Ha, Kwang Soon; Kim, Jong Tae; Kim, Hwan Yeol

    2009-11-01

    An auto-door hinge, which is one of the automatic door-closing apparatuses, has been widely used to prevent fire propagations in living or commercial buildings. The auto-door hinge consists of a spring to accumulate power for closing a door and an oil damper to control door-closing velocity. To predict and optimize the temporal door behavior during the door-closing period, the auto-door closing system was modeled as a second order-damping system. And a damping coefficient of the oil damper was also theoretically modeled by analyzing Newtonian, incompressible, viscous flow through an oil passage between a oil control rod and a oil piston body. The temporal door behaviors during the door-closing period were predicted with respect to the gap distance of the oil passage, oil viscosity, and pre-compressing of the spring. Temporal door behavior measurement method using an encoder system was also developed to validate the modelling on the oil damping system. As using the developed test apparatus, the temporal door position, velocity, and rotational torque were measured, and the modelling method was evaluated

  15. A Study on the Modeling of the Oil Damper in an Auto-Door Hinge

    Energy Technology Data Exchange (ETDEWEB)

    Ha, Kwang Soon; Kim, Jong Tae; Kim, Hwan Yeol

    2009-11-15

    An auto-door hinge, which is one of the automatic door-closing apparatuses, has been widely used to prevent fire propagations in living or commercial buildings. The auto-door hinge consists of a spring to accumulate power for closing a door and an oil damper to control door-closing velocity. To predict and optimize the temporal door behavior during the door-closing period, the auto-door closing system was modeled as a second order-damping system. And a damping coefficient of the oil damper was also theoretically modeled by analyzing Newtonian, incompressible, viscous flow through an oil passage between a oil control rod and a oil piston body. The temporal door behaviors during the door-closing period were predicted with respect to the gap distance of the oil passage, oil viscosity, and pre-compressing of the spring. Temporal door behavior measurement method using an encoder system was also developed to validate the modelling on the oil damping system. As using the developed test apparatus, the temporal door position, velocity, and rotational torque were measured, and the modelling method was evaluated.

  16. Dynamic Analysis of a Rotor System Supported on Squeeze Film Damper with Air Entrainment

    Science.gov (United States)

    Zhang, Wei; Han, Bingbing; Zhang, Kunpeng; Ding, Qian

    2017-12-01

    Squeeze film dampers (SFDs) are widely used in compressors and turbines to suppress the vibration while traversing critical speeds. In practical applications, air ingestion from the outside environment and cavitation may lead to a foamy lubricant that weakens oil film damping and dynamic performance of rotor system. In this paper, a rigid rotor model is established considering both lateral and pitching vibration under different imbalance excitations to evaluate the effect of air entrainment on rotor system. Tests with three different imbalances are carried out on a rotor-SFD apparatus. Volume controlled air in mixture ranging from pure oil to all air are supplied to the SFD. The transient response of rotor is measured in the experiments. The results show that two-phase flow produces significant influence on the system stability and dynamical response. The damping properties are weakened by entrained air, such as the damping on high frequency components of rolling ball bearing. Super-harmonic resonance and bifurcation are observed, as well as the low frequency components due to air entrainment.

  17. Using magnetorheological fluids in an innovative hybrid bicycle damper

    International Nuclear Information System (INIS)

    Shiao, Y J; Nguyen, T S

    2015-01-01

    Magnetorheological fluids are capable of changing their viscosity quickly. This can provide good controllability and fast dynamic response. A conventional passive suspension system with air spring or hydraulic damper has simple design and financial benefit for bicycles, but its operation is uncontrollable and non-adaptive. This paper presented a semi-active hybrid bicycle suspension system which combines conventional air spring and a new magnetorheological damping brake together to reduce vibration of a bicycle. A multi-layer magnetorheological brake and linkage mechanism are connected to bike fork to form the adaptive damping part of the innovative hybrid suspension system. The simulation results proved that the semi-active suspension system can reduce bike vibration effectively. (paper)

  18. Performance and robustness of hybrid model predictive control for controllable dampers in building models

    Science.gov (United States)

    Johnson, Erik A.; Elhaddad, Wael M.; Wojtkiewicz, Steven F.

    2016-04-01

    A variety of strategies have been developed over the past few decades to determine controllable damping device forces to mitigate the response of structures and mechanical systems to natural hazards and other excitations. These "smart" damping devices produce forces through passive means but have properties that can be controlled in real time, based on sensor measurements of response across the structure, to dramatically reduce structural motion by exploiting more than the local "information" that is available to purely passive devices. A common strategy is to design optimal damping forces using active control approaches and then try to reproduce those forces with the smart damper. However, these design forces, for some structures and performance objectives, may achieve high performance by selectively adding energy, which cannot be replicated by a controllable damping device, causing the smart damper performance to fall far short of what an active system would provide. The authors have recently demonstrated that a model predictive control strategy using hybrid system models, which utilize both continuous and binary states (the latter to capture the switching behavior between dissipative and non-dissipative forces), can provide reductions in structural response on the order of 50% relative to the conventional clipped-optimal design strategy. This paper explores the robustness of this newly proposed control strategy through evaluating controllable damper performance when the structure model differs from the nominal one used to design the damping strategy. Results from the application to a two-degree-of-freedom structure model confirms the robustness of the proposed strategy.

  19. Synthesis of lever-blade dampers with enhanced mechanical structure

    Directory of Open Access Journals (Sweden)

    Igor I. Sydorenko

    2015-03-01

    Full Text Available Since the torsion bar represents just an elastic element, the energy dissipation in suspensions problem is highly relevant for its application. Currently in quality of a dissipation device in torsion suspension are used the hydraulic dampers with movable members reciprocating translational motion respectively to the housing or lever-type hydraulic shock absorbers of piston and vane types, with the movable member’s rotational movement respectively to the housing. These dampers are implementing only throttle-valve performance type, associated with these devices’ functional capacities and depending on design constraints. The paper presents a synthesis of innovative lever-blade dampers, whose performance is not related to the value of working chambers inner pressure. Their essential peculiarity relates to the mechanical control loop presence in the structure that determines a close relationship between the performance and the value of the shock absorber movable element displacement relatively to the body. In the process of synthesis carried out tested are the appropriate methods, built on the basis of technical systems’ modeling with modified kinematic graphs. The synthesis results are shown in the form of two structurally implemented samples. Performed is a comparative analysis of the samples with their basic performance determining.

  20. An Experimental Design of Bypass Magneto-Rheological (MR) damper

    Science.gov (United States)

    Rashid, MM; Aziz, Mohammad Abdul; Raisuddin Khan, Md.

    2017-11-01

    The magnetorheological (MR) fluid bypass damper fluid flow through a bypass by utilizing an external channel which allows the controllability of MR fluid in the channel. The Bypass MR damper (BMRD) contains a rectangular bypass flow channel, current controlled movable piston shaft arrangement and MR fluid. The static piston coil case is winding by a coil which is used inside the piston head arrangement. The current controlled coil case provides a magnetic flux through the BMRD cylinder for controllability. The high strength of alloy steel materials are used for making piston shaft which allows magnetic flux propagation throughout the BMRD cylinder. Using the above design materials, a Bypass MR damper is designed and tested. An excitation of current is applied during the experiment which characterizes the BMRD controllability. It is shown that the BMRD with external flow channel allows a high controllable damping force using an excitation current. The experimental result of damping force-displacement characteristics with current excitation and without current excitation are compared in this research. The BMRD model is validated by the experimental result at various frequencies and applied excitation current.

  1. Application of tuned mass dampers in high-rise construction

    Science.gov (United States)

    Teplyshev, Vyacheslav; Mylnik, Alexey; Pushkareva, Maria; Agakhanov, Murad; Burova, Olga

    2018-03-01

    The article considers the use of tuned mass dampers in high-rise construction for significant acceleration and amplitude of vibrations of the upper floors under dynamic wind influences. The susceptibility of people to accelerations in high-rise buildings and possible means of reducing wind-induced fluctuations in buildings are analyzed. The statistics of application of tuned mass dampers in high-rise construction all over the world is presented. The goal of the study is to identify an economically attractive solution that allows the fullest use of the potential of building structures in high-rise construction, abandoning the need to build massive frames leading to over-consumption of materials.

  2. Seismic Responses of an Added-Story Frame Structure with Viscous Dampers

    OpenAIRE

    Cheng, Xuansheng; Jia, Chuansheng; Zhang, Yue

    2014-01-01

    The damping ratio of an added-story frame structure is established based on complex damping theory to determine the structure seismic response. The viscous dampers are selected and arranged through target function method. A significant damping effect is obtained when a small velocity index is selected. The seismic responses of a five-floor reinforced concrete frame structure with directly added light steel layers and light steel layers with viscous dampers are compared with the finite element...

  3. Proposal for the Award of a Contract for the Supply of 40 Broadband Transistorised RF 200 W Amplifiers for the LHC Transverse Damper System

    CERN Document Server

    2003-01-01

    This document concerns the award of a contract for the supply of 40 broadband transistorised RF 200 W amplifiers for the LHC transverse damper system. Following a market survey carried out among 30 firms in twelve Member States, a call for tenders (IT-3171/SL/LHC) was sent on 20 February 2003 to five firms in four Member States. By the closing date, CERN had received two tenders from two firms in two Member States. The Finance Committee is invited to agree to the negotiation of a contract with THALES (BE), the lowest bidder complying with the specification, for the supply of 40 broadband transistorised RF 200 W amplifiers for the LHC transverse damper system for a total amount of 1 044 819 euros (1 563 049 Swiss francs), not subject to revision, with an option for an additional 20 broadband transistorised RF amplifiers, for an additional amount of 305 740 euros (457 387 Swiss francs), subject to revision for inflation from 1 July 2005, bringing the total amount to a maximum of 1 350 559 euros (2 020 436 Swiss...

  4. Warm damper for a superconducting rotor

    International Nuclear Information System (INIS)

    Hooper, G.D.

    1984-01-01

    A warm damper for a superconducting rotor is described which uses a laminar assembly of a conductive tube and a plurality of support tubes. The conductive tube is soldered to axially adjacent support tubes and the resulting composite tube is explosively welded to two or more support tubes disposed adjacent to its radially inner and outer surfaces

  5. Characterization and modeling of a new magnetorheological damper with meandering type valve using neuro-fuzzy

    Directory of Open Access Journals (Sweden)

    Fitrian Imaduddin

    2017-10-01

    Full Text Available This paper presents the characterization and hysteresis modeling of magnetorheological (MR damper with meandering type valve. The meandering type MR valve, which employs the combination of multiple annular and radial flow passages, has been introduced as the new type of high performance MR valve with higher achievable pressure drop and controllable performance range than similar counterparts in its class. Since the performance of a damper is highly determined by the valve performance, the utilization of the meandering type MR valve in an MR damper could potentially improve the damper performance. The damping force characterization of the MR damper is conducted by measuring the damping force as a response to the variety of harmonic excitations. The hysteresis behavior of the damper is identified by plotting the damping force relationship to the excitation displacement and velocity. For the hysteresis modeling purpose, some parts of the data are taken as the training data source for the optimization parameters in the neuro-fuzzy model. The performance of the trained neuro-fuzzy model is assessed by validating the model output with the remaining measurement data and benchmarking the results with the output of the parametric hysteresis model. The validation results show that the neuro-fuzzy model is demonstrating good agreement with the measurement results indicated by the average relative error of only around 7%. The model also shows robustness with no tendency of growing error when the input values are changed.

  6. Future approaches to digital systems

    International Nuclear Information System (INIS)

    Woodrough, R.E.; Beckmann, E.; Jenkins, D.; Belcher, D.

    1984-01-01

    The introduction of the first digital imaging systems has led to the concept of a totally digital imaging department - the 'filmless department'. This concept and its associated network system for digital departments are briefly considered. A transducer system of scanned projection radiography with solid state detectors used in digital chest imaging is described. The principles of this transducer system are applicable to other forms of digital radiography. (U.K.)

  7. THE THEORETICAL FOUNDATIONS OF VIBRATION DAMPERS BY ROLLING FRICTION

    Directory of Open Access Journals (Sweden)

    L. M. Bondarenko

    2015-06-01

    Full Text Available Purpose. There are some unresolved issues in vibration damping – the lack of engineering calculations for the vibration dampers by rolling friction; the absence of evidence of their application appropriateness. Considering this fact, the authors suggest to prove that the dampers based on rolling friction, are similar in rate of oscillation damping by hydraulic shock absorbers. At the same time, they are easier for the hydraulic design, and easily amenable to manual adjustment, both in automatic and manual mode. Methodology. Fixed techniques of practice in order to determine amplitudes of the oscillations of a shock absorber led to a predetermined result and will apply this theory in the calculation of other vibration dampers. Findings. Analysis of the formulas and graphs leads to the following conclusions and recommendations: 1 the nature of the oscillation damping at vibration dampers by rolling friction is close to their decay in the viscous resistance; 2 when conducting the necessary experiments the shock absorber rolling can be recommended as alternatives to hydraulic ones. The research results of this task will help implement the new trend in reduction of dynamic loads in vehicles. Originality. With the help of theoretical curves to determine the coefficients of rolling friction the dependences for determining the amplitudes of the oscillations in the vertical movement of cargo were obtained. At the same time, the previously proposed analytical dependence for determining the coefficient of rolling friction contains only conventional mechanical constants of the contacting bodies and there geometrical dimensions. Practical value. Due to the existing well-known disadvantages of hydraulic shock absorbers it would be logical to apply shock absorbers that are technologically convenient in manufacturing and easy to adjust the damping rate. The proposed theory can be used in the design of shock absorbers rolling as an alternative to the hydraulic

  8. Seismic Responses of an Added-Story Frame Structure with Viscous Dampers

    Directory of Open Access Journals (Sweden)

    Xuansheng Cheng

    2014-01-01

    Full Text Available The damping ratio of an added-story frame structure is established based on complex damping theory to determine the structure seismic response. The viscous dampers are selected and arranged through target function method. A significant damping effect is obtained when a small velocity index is selected. The seismic responses of a five-floor reinforced concrete frame structure with directly added light steel layers and light steel layers with viscous dampers are compared with the finite element software SAP2000. Calculation results show that, after adding the layers, the structure becomes flexible and the shear in the bottom layer decreases. However, the interlaminar shear of the other layers increases. The seismic response of the added layers is very significant and exhibits obvious whiplash effect. The interstory displacement angles of some layers do not meet the requirements. The seismic response of the structure decreases after the adoption of viscous dampers; thereby seismic requirements are satisfied.

  9. ESM vibration dampers: the intelligent way to take care of components; ESM Schwingungsdaempfer: Bauteile intelligent geschont

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    2007-07-01

    Three-Point Suspension: In wind turbines with stall and pitch systems of every size the three-point suspension with clamping bushings of ESM is very common. It is the task of the vibration isolation to suspend the gearbox elastically on the main frame at two mounting points. Four-Point Suspension: Particularly in wind turbines of the multi-megawatt-class the four-point suspension is a more and more spreading system. The rotor shaft is supported by one bearing which is able to take the yaw and nodding torques or by two rotor shaft bearings. So all the torques except the driving torque are directly transferred to the main frame by the rotor shaft support. The gearbox has only one degree of freedom left. To avoid horizontal constraint forces on the gearbox with the four-point suspension normally multi-sandwich mounts or a pendulum support is used as both have a very low horizontal stiffness. One problem persists anyway: Due to assembly tolerances and main frame deformations because of nodding torques the gearbox has to withstand huge vertical constriant forces. Especially for wind turbines with four-point suspension ESM has developed a hydraulic gearbox support. Generator Suspension: In wind turbines with a gearbox and a fast running generator the generator is mounted to the main frame with normally four elastomeric generator mounts. Tuned Mass Dampers: Tuned mass dampers are used to reduce single tone vibrations in machines, buildings and other facilities. The function of a tuned mass damper is based on an oscillating mass which moves contrary to the spurious vibration and reduces it thereby. ESM has developed easy adjustable tuned mass dampers, which may be installed to a wind turbine easily if a wind turbine has problems with single tone vibrations. (orig.)

  10. Magneto Rheological Semi-Active Damper with External By-pass Circuit in Modular Structure

    Directory of Open Access Journals (Sweden)

    Alexandru Boltoşi

    2010-10-01

    Full Text Available In order to perform experimentally studies, in the paper it is presented a simple method which was elaborated to realize reliable, at low cost and reproducible semi-active dampers with magnetorheological fluids, having external magnetic circuit. The main components are common constitutive elements of industrial hydraulic and pneumatic drivers, having the supplementary advantages being manufactured in a large scale of overall dimensions and demanding minimal modifications. As accumulator, a similar type of hydraulic or pneumatic cylinder was used. The work of the whole damper can be optimized by modifying the nitrogen pressure and interior volume of accumulator. Another important advantage of this conception is the possibility to realize a modular structure composed by the damper, accumulator and magnetic field generator, interconnected by flexible elements.

  11. Fault detection and fault tolerant control of a smart base isolation system with magneto-rheological damper

    International Nuclear Information System (INIS)

    Wang, Han; Song, Gangbing

    2011-01-01

    Fault detection and isolation (FDI) in real-time systems can provide early warnings for faulty sensors and actuator signals to prevent events that lead to catastrophic failures. The main objective of this paper is to develop FDI and fault tolerant control techniques for base isolation systems with magneto-rheological (MR) dampers. Thus, this paper presents a fixed-order FDI filter design procedure based on linear matrix inequalities (LMI). The necessary and sufficient conditions for the existence of a solution for detecting and isolating faults using the H ∞ formulation is provided in the proposed filter design. Furthermore, an FDI-filter-based fuzzy fault tolerant controller (FFTC) for a base isolation structure model was designed to preserve the pre-specified performance of the system in the presence of various unknown faults. Simulation and experimental results demonstrated that the designed filter can successfully detect and isolate faults from displacement sensors and accelerometers while maintaining excellent performance of the base isolation technology under faulty conditions

  12. Digital and analog communication systems

    Science.gov (United States)

    Shanmugam, K. S.

    1979-01-01

    The book presents an introductory treatment of digital and analog communication systems with emphasis on digital systems. Attention is given to the following topics: systems and signal analysis, random signal theory, information and channel capacity, baseband data transmission, analog signal transmission, noise in analog communication systems, digital carrier modulation schemes, error control coding, and the digital transmission of analog signals.

  13. Energy-Dissipation Performance of Combined Low Yield Point Steel Plate Damper Based on Topology Optimization and Its Application in Structural Control

    Directory of Open Access Journals (Sweden)

    Haoxiang He

    2016-01-01

    Full Text Available In view of the disadvantages such as higher yield stress and inadequate adjustability, a combined low yield point steel plate damper involving low yield point steel plates and common steel plates is proposed. Three types of combined plate dampers with new hollow shapes are proposed, and the specific forms include interior hollow, boundary hollow, and ellipse hollow. The “maximum stiffness” and “full stress state” are used as the optimization objectives, and the topology optimization of different hollow forms by alternating optimization method is to obtain the optimal shape. Various combined steel plate dampers are calculated by finite element simulation, the results indicate that the initial stiffness of the boundary optimized damper and interior optimized damper is lager, the hysteresis curves are full, and there is no stress concentration. These two types of optimization models made in different materials rations are studied by numerical simulation, and the adjustability of yield stress of these combined dampers is verified. The nonlinear dynamic responses, seismic capacity, and damping effect of steel frame structures with different combined dampers are analyzed. The results show that the boundary optimized damper has better energy-dissipation capacity and is suitable for engineering application.

  14. Semi-Active Control of Three-Dimensional Vibrations of an Inclined Sag Cable with Magnetorheological Dampers

    DEFF Research Database (Denmark)

    Zhou, Q.; Nielsen, Søren R.K.; Qu, W. L.

    2006-01-01

    Three-dimensional semi-active vibration control of an inclined sag cable with discrete magnetorheological (MR) dampers is investigated in this paper using the finite difference method (FDM). A modified Dahl model is used to describe the dynamic property of MR damper. The nonlinear equations...

  15. A novel self-powered MR damper: theoretical and experimental analysis

    International Nuclear Information System (INIS)

    Xinchun, Guan; Hui, Li; Jinping, Ou; Yonghu, Huang; Yi, Ru

    2015-01-01

    This paper presents a novel magnetorheological (MR) damper with a self-powered capability, which is proposed to have energy harvesting and MR damping technologies integrated into a single device. Vibration energy harvesting mechanisms were adopted, based on ball-screw mechanisms and a rotary permanent magnet dc generator, to convert the external vibration energy into electrical energy to power the MR damping unit. The configuration and operating principles of the proposed self-powered MR damper were presented. Considering the core loss effect on the magnetic field, a theoretical analysis of the proposed MR damper was carried out and a mechanical model was developed. Finally, a prototype with a capacity of 10 kN was fabricated and experimentally investigated in both the direct-supply mode and the supply-with-rectifier mode. The results indicated that the proposed configuration is feasible and that both modes can realize good self-adaptability of the MR damping force. However, the direct-supply mode has a sag effect in the force–displacement curve and provides a lower energy-dissipating capacity than the direct-supply mode does under the same conditions. (paper)

  16. Friction dampers, the positive side of friction

    NARCIS (Netherlands)

    Lopez Arteaga, I.; Nijmeijer, H.; Busturia, J.M.; Sas, P.; Munck, de M.

    2004-01-01

    Friction is frequently seen as an unwanted phenomenon whose influence has to be either minimised or controlled. In this work one of the positive sides of friction is investigated: friction damping. Friction dampers can be a cheap and efficient way to reduce the vibration levels of a wide range of

  17. Nonlinear Study of Industrial Arc Spring Dampers

    DEFF Research Database (Denmark)

    Lahriri, Said; Santos, Ilmar; Hartmann, Henning

    2011-01-01

    acting on the SFD are presented. It is worth mentioning, that the maps and diagrams can be used as design guidance. Finally, a comparison between the numerical results and experimental result is facilitated in form of waterfall diagrams. For this, a full scale model of the arc-spring damper was designed...

  18. LHC Abort Gap Cleaning with the Transverse Damper

    CERN Document Server

    Gianfelice-Wendt, E; Höfle, Wolfgang; Kain, V; Meddahi, M; Shaposhnikova, E; Koschik, A

    2010-01-01

    In the Large Hadron Collider, LHC, particles not captured by the RF system at injection or leaking out of the RF bucket may quench the superconducting magnets during beam abort. The problem, common to other superconducting machines, is particularly serious for the LHC due to the very large stored energy in the beam. For the LHC a way of removing the unbunched beam has been studied and it uses the existing damper kickers to excite resonantly the particles travelling along the abort gap. In this paper we describe the results of simulations performed with MAD X for various LHC optics configurations, including the estimated multipolar errors.

  19. A comparison of 200 kN magneto-rheological damper models for use in real-time hybrid simulation pretesting

    International Nuclear Information System (INIS)

    Jiang, Z; Christenson, R

    2011-01-01

    Control devices can be used to dissipate the energy of a civil structure subjected to dynamic loading, such as earthquake, wave and wind excitation, thus reducing structural damage and preventing failure. The magneto-rheological (MR) fluid damper is a promising device for use in civil structures due to its mechanical simplicity, inherent stability, high dynamic range, large temperature operating range, robust performance, and low power requirements. The MR damper is intrinsically nonlinear and rate dependent. Thus a challenging aspect of applying this technology is the development of accurate models to describe the behavior of such dampers for control design and evaluation purposes. In particular, a new type of experimental testing called real-time hybrid simulation (RTHS) combines numerical simulation with laboratory testing of physical components. As with any laboratory testing, safety is of critical importance. For RTHS in particular the feedback and dynamic interaction of physical and numerical components can result in potentially unstable behavior. For safety purposes, it is desired to conduct pretest simulations where the physical specimen is replaced with an appropriate numerical model yet the numerical RTHS component is left unchanged. These pretest simulations require a MR damper model that can exhibit stability and convergence at larger fixed integration time steps, and provide computational efficiency, speed of calculation, and accuracy during pretest verification of the experimental setup. Several models for MR dampers have been proposed, including the hyperbolic tangent, Bouc–Wen, viscous plus Dahl and algebraic models. This paper examines the relative performance of four MR damper models of large-scale 200 kN MR dampers as needed for pretest simulations of RTHS. Experimental tests are conducted on two large-scale MR dampers located at two RTHS test facilities at the Smart Structures Technology Laboratory at the University of Illinois at Urbana

  20. The partially filled viscous ring damper.

    Science.gov (United States)

    Alfriend, K. T.

    1973-01-01

    The problem of a spinning satellite with a partially filled viscous ring damper is investigated. It is shown that there are two distinct modes of motion, the nutation-synchronous mode and spin-synchronous mode. From an approximate solution of the equations of motion a time constant is obtained for each mode. From a consideration of the fluid dynamics several methods are developed for determining the damping constant.

  1. Studies on Horizontal Axis Wind Turbine with Passive Teetered Brake & Damper Mechanism

    OpenAIRE

    SHIMIZU, Yukimaru; KAMADA, Yasunari; MAEDA, Takao

    1998-01-01

    In order to improve the reliability of megawatt wind turbines, the passive teetered brake & damper mechanism is applied. Its two unique effects, as its name implies, are braking and damping. The passive brake & damper mechanism is useful for variable speed control of the large wind turbine. It is comprised of teetering and feathering mechanisms. When the wind speed exceeds the rated wind speed, the blade is passively teetered in a downwind direction and, at the same time, a feathering mechani...

  2. A novel magnetorheological damper based parallel planar manipulator design

    International Nuclear Information System (INIS)

    Hoyle, A; Arzanpour, S; Shen, Y

    2010-01-01

    This paper presents a novel parallel planar robot design which is low cost and simple in structure. The design addresses some of the problems, such as concentration of excessive load on the links and joints, due to wrong commanding signals being given by the controller. In this application two of the conventional actuators are replaced by magnetorheological (MR) dampers, and only one actuator is used to generate motion. The design paradigm is based on the concept that a moving object 'intuitively' follows the path with minimum resistance to its motion. This implies that virtual adoptable constraints can be used effectively to define motion trajectories. In fact, motion generation and adaptive constraints are two elements essential to implementing this strategy. In this paper, MR dampers are used to provide adjustable constraints and to guide the platform that is moved by the linear motor. The model of the MR dampers is derived using the Bouc–Wen model. This model is then used for manipulator simulation and controller design. Two controllers are developed for this manipulator: (1) a closed loop on/off one and (2) a proportional–derivative controller. Also, three different trajectories are defined and used for both the simulations and experiments. The results indicate a good agreement between the simulations and experiments. The experimental results also demonstrate the capability of the manipulator for following sophisticated trajectories

  3. Damping the e-p instability in the SNS accumulator ring

    Science.gov (United States)

    Evans, N. J.; Deibele, C.; Aleksandrov, A.; Xie, Z.

    2018-03-01

    A broadband, digital damper system for both transverse planes developed for the SNS accumulator ring has recently damped the first indications of the broadband 50-150 MHz e-p instability in a 1.2 MW neutron production beam. This paper presents details of the design and operation of the SNS damper system as well as results of active damping of the e-p instability in the SNS ring showing a reduction in power of betatron oscillation over the 10-300 MHz band of up to 70%. The spectral content of the beam during operation, with and without the damper system is presented and performance of the damper system is evaluated.

  4. Semiactive Control Using MR Dampers of a Frame Structure under Seismic Excitation

    International Nuclear Information System (INIS)

    Gattulli, Vincenzo; Lepidi, Marco; Potenza, Francesco; Carneiro, Rubia

    2008-01-01

    The paper approaches the multifaceted task of semiactively controlling the seismic response of a prototypal building model, through interstorey bracings embedding magnetorheological dampers. The control strategy is based on a synthetic discrete model, purposely formulated in a reduced space of significant dynamic variables, and consistently updated to match the modal properties identified from the experimental response of the modeled physical structure. The occurrence of a known eccentricity in the mass distribution, breaking the structural symmetry, is also considered. The dissipative action of two magnetorheological dampers is governed by a clipped-optimal control strategy. The dampers are positioned in order to deliver two eccentric and independent forces, acting on the first-storey displacements. This set-up allows the mitigation of the three-dimensional motion arising when monodirectional ground motion is imposed on the non-symmetric structure. Numerical investigations on the model response to natural accelerograms are presented. The effectiveness of the control strategy is discussed through synthetic performance indexes

  5. The spectral analysis of an aero-engine assembly incorporating a squeeze-film damper

    Science.gov (United States)

    Holmes, R.; Dede, M. M.

    1989-01-01

    Aero-engine structures have very low inherent damping and so artificial damping is often introduced by pumping oil into annular gaps between the casings and the outer races of some or all of the rolling-element bearings supporting the rotors. The thin oil films so formed are called squeeze film dampers and they can be beneficial in reducing rotor vibration due to unbalance and keeping to reasonable limits the forces transmitted to the engine casing. However, squeeze-film dampers are notoriously non-linear and as a result can introduce into the assembly such phenomena as subharmonic oscillations, jumps and combination frequencies. The purpose of the research is to investigate such phenomena both theoretically and experimentally on a test facility reproducing the essential features of a medium-size aero engine. The forerunner of this work was published. It was concerned with the examination of a squeeze-film damper in series with housing flexibility when supporting a rotor. The structure represented to a limited extent the essentials of the projected Rolls Royce RB401 engine. That research demonstrated the ability to calculate the oil-film forces arising from the squeeze film from known motions of the bearing components and showed that the dynamics of a shaft fitted with a squeeze film bearing can be predicted reasonably accurately. An aero-engine will normally have at least two shafts and so in addition to the excitation forces which are synchronous with the rotation of one shaft, there will also be forces at other frequencies from other shafts operating on the squeeze-film damper. Theoretical and experimental work to consider severe loading of squeeze-film dampers and to include these additional effects are examined.

  6. Linear and nonlinear analysis of fluid slosh dampers

    Science.gov (United States)

    Sayar, B. A.; Baumgarten, J. R.

    1982-11-01

    A vibrating structure and a container partially filled with fluid are considered coupled in a free vibration mode. To simplify the mathematical analysis, a pendulum model to duplicate the fluid motion and a mass-spring dashpot representing the vibrating structure are used. The equations of motion are derived by Lagrange's energy approach and expressed in parametric form. For a wide range of parametric values the logarithmic decrements of the main system are calculated from theoretical and experimental response curves in the linear analysis. However, for the nonlinear analysis the theoretical and experimental response curves of the main system are compared. Theoretical predictions are justified by experimental observations with excellent agreement. It is concluded finally that for a proper selection of design parameters, containers partially filled with viscous fluids serve as good vibration dampers.

  7. Advanced damper with negative structural stiffness elements

    International Nuclear Information System (INIS)

    Dong, Liang; Lakes, Roderic S

    2012-01-01

    Negative stiffness is understood as the occurrence of a force in the same direction as the imposed deformation. Structures and composites with negative stiffness elements enable a large amplification in damping. It is shown in this work, using an experimental approach, that when a flexible flat-ends column is aligned in a post-buckled condition, a negative structural stiffness and large hysteresis (i.e., high damping) can be achieved provided the ends of the column undergo tilting from flat to edge contact. Stable axial dampers with initial modulus equivalent to that of the parent material and with enhanced damping were designed and built using constrained negative stiffness effects entailed by post-buckled press-fit flat-ends columns. Effective damping of approximately 1 and an effective stiffness–damping product of approximately 1.3 GPa were achieved in such stable axial dampers consisting of PMMA columns. This is a considerable improvement for this figure of merit (i.e., the stiffness–damping product), which generally cannot exceed 0.6 GPa for currently used damping layers. (paper)

  8. Stability of a dual-spin satellite with two dampers

    Science.gov (United States)

    Alfriend, K. T.; Hubert, C. H.

    1974-01-01

    The rotational stability of a dual-spin satellite consisting of a main body and a symmetric rotor, both spinning about a common axis, is investigated. The main body is equipped with a spring-mass damper, while a partially filled viscous ring damper is mounted on the rapidly spinning rotor. The effect of fluid motion on the rotational stability of the satellite is calculated, considering the fluid as a single particle moving in a tube with viscous damping. Time constants are obtained by solving approximate equations of motion for the nutation-synchronous and the spin-synchronous modes, and the results are found to agree well with the numerical integrations of the exact equations. A limit cycle may exist for some configurations; the nutation angle tends to increase in such cases.

  9. Superconductor Digital-RF Receiver Systems

    Science.gov (United States)

    Mukhanov, Oleg A.; Kirichenko, Dmitri; Vernik, Igor V.; Filippov, Timur V.; Kirichenko, Alexander; Webber, Robert; Dotsenko, Vladimir; Talalaevskii, Andrei; Tang, Jia Cao; Sahu, Anubhav; Shevchenko, Pavel; Miller, Robert; Kaplan, Steven B.; Sarwana, Saad; Gupta, Deepnarayan

    Digital superconductor electronics has been experiencing rapid maturation with the emergence of smaller-scale, lower-cost communications applications which became the major technology drivers. These applications are primarily in the area of wireless communications, radar, and surveillance as well as in imaging and sensor systems. In these areas, the fundamental advantages of superconductivity translate into system benefits through novel Digital-RF architectures with direct digitization of wide band, high frequency radio frequency (RF) signals. At the same time the availability of relatively small 4K cryocoolers has lowered the foremost market barrier for cryogenically-cooled digital electronic systems. Recently, we have achieved a major breakthrough in the development, demonstration, and successful delivery of the cryocooled superconductor digital-RF receivers directly digitizing signals in a broad range from kilohertz to gigahertz. These essentially hybrid-technology systems combine a variety of superconductor and semiconductor technologies packaged with two-stage commercial cryocoolers: cryogenic Nb mixed-signal and digital circuits based on Rapid Single Flux Quantum (RSFQ) technology, room-temperature amplifiers, FPGA processing and control circuitry. The demonstrated cryocooled digital-RF systems are the world's first and fastest directly digitizing receivers operating with live satellite signals in X-band and performing signal acquisition in HF to L-band at ˜30GHz clock frequencies.

  10. Fundamental damper power calculation of the 56 MHz SRF cavity for RHIC

    International Nuclear Information System (INIS)

    Wu, Q.; Bellavia, S.; Ben-Zvi, I.; Grau, M.; Miglionico, G.; Pai, C.

    2011-01-01

    At each injection period during RHIC's operation, the beam's frequency sweeps across a wide range, and some of its harmonics will cross the frequency of the 56MHz SRF cavity. To avoid excitation of the cavity at these times, we designed a fundamental damper for the quarter-wave resonator to damp the cavity heavily. The power extracted by the fundamental damper should correspond to the power handling ability of the system at all stages. In this paper, we discuss the power output from the fundamental damper when it is fully extracted, inserted, and any intermediate point. A Fundamental Damper (FD) will greatly reduce the cavity's Q factor to ∼300 during the acceleration phase of the beam. However, when the beam is at store and the FD is removed, the cavity is excited by both the yellow and the blue beams at 2 x 0.3A to attain the required 2MV voltage across its gap. The cavity then is operated to increase the luminosity of the RHIC experiments. Table 1 lists the parameters of the FD. Figure 1 shows the configuration of the FD fully inserted into the 56MHz SRF cavity; this complete insertion is defined as the start location (0cm) of FD simulation, an assumption we make throughout this paper. The power consumed by the cavity while maintaining the beam's energy and its orbit is compensated by the 28MHz accelerating cavities in the storage ring. The power dissipation of the external load is dynamic with respect to the position of the FD during its extraction. As a function of the external Q and the EM field in the cavity, the power should peak with the FD at a certain vertical location. Our calculation of the power extracted is detailed in the following sections. Figure 2 plots the frequency change in the cavity, and the external Q against the changes in position of the FD. The location of the FD is selected carefully such that the frequency will approach the designed working point from the lower side only. The loaded Q of the cavity is 223 when the FD is fully

  11. A new vibration isolation bed stage with magnetorheological dampers for ambulance vehicles

    International Nuclear Information System (INIS)

    Chae, Hee Dong; Choi, Seung-Bok

    2015-01-01

    The vibration experienced in an ambulance can lead to secondary injury to a patient and discourage a paramedic from providing emergency care. In this study, with the goal of resolving this problem, a new vibration isolation bed stage associated with magnetorheological (MR) dampers is proposed to ensure ride quality as well as better care for the patient while he/she is being transported. The bed stage proposed in this work can isolate vibrations in the vertical, rolling and pitching directions to reflect the reality that occurs in the ambulance. Firstly, an appropriate-sized MR damper is designed based on the field-dependent rheological properties of MR fluid, and the damping force characteristics of a MR damper are evaluated as a function of the current. A mechanical model of the proposed vibration isolation bed stage is then established to derive the governing equations of motion. Subsequently, a sliding mode controller is formulated to control the vibrations caused from the imposed excitation signals; those signals are directly measured using a real ambulance subjected to bump-and-curve road conditions. Using the controller based on the dynamic motion of the bed stage, the vibration control performance is evaluated in both the vertical and pitch directions. It is demonstrated that the magnitude of the vibration in the patient compartment of the ambulance can be significantly reduced by applying an input current to the MR dampers installed for the new bed stage. (technical note)

  12. Dynamic Model of MR Dampers Based on a Hysteretic Magnetic Circuit

    Directory of Open Access Journals (Sweden)

    Pengfei Guo

    2018-01-01

    Full Text Available As a key to understand dynamic performances of MR dampers, a comprehensive dynamic magnetic circuit model is proposed in this work on the basis of Ampere’s and Gauss’s laws. It takes into account not only the magnetic saturation, which many existing studies have focused on, but also the magnetic hysteresis and eddy currents in a MR damper. The hysteresis of steel parts of MR dampers is described by Jiles-Atherton (J-A models, and the eddy current is included based on the field separation. Compared with the FEM results, the proposed model is validated in low- and high-frequency studies for the predictions of the magnetic saturation, the hysteresis, and the effect of eddy currents. A simple multiphysics model is developed to demonstrate how to combine the proposed magnetic circuit model with the commonly used Bingham fluid model. The damping force in the high-frequency case obviously lags behind the coil current, which exhibits a hysteresis loop in the current-force plane. The lag of damping force even exists in a low-frequency varying magnetic field and becomes more severe in the presence of eddy currents.

  13. Introduction to digital communication systems

    CERN Document Server

    Wesolowski, Krzysztof

    2009-01-01

    Combining theoretical knowledge and practical applications, this advanced-level textbook covers the most important aspects of contemporary digital communication systems. Introduction to Digital Communication Systems focuses on the rules of functioning digital communication system blocks, starting with the performance limits set by the information theory. Drawing on information relating to turbo codes and LDPC codes, the text presents the basic methods of error correction and detection, followed by baseband transmission methods, and single- and multi-carrier digital modulations. The basi

  14. Earthquake Response of Reinforced Concrete Building Retrofitted with Geopolymer Concrete and X-shaped Metallic Damper

    Science.gov (United States)

    Madheswaran, C. K.; Prakash vel, J.; Sathishkumar, K.; Rao, G. V. Rama

    2017-06-01

    A three-storey half scale reinforced concrete (RC) building is fixed with X-shaped metallic damper at the ground floor level, is designed and fabricated to study its seismic response characteristics. Experimental studies are carried out using the (4 m × 4 m) tri-axial shake-table facility to evaluate the seismic response of a retrofitted RC building with open ground storey (OGS) structure using yielding type X-shaped metallic dampers (also called as Added Damping and Stiffness-ADAS elements) and repairing the damaged ground storey columns using geopolymer concrete composites. This elasto-plastic device is normally incorporated within the frame structure between adjacent floors through chevron bracing, so that they efficiently enhance the overall energy dissipation ability of the seismically deficient frame structure under earthquake loading. Free vibration tests on RC building without and with yielding type X-shaped metallic damper is carried out. The natural frequencies and mode shapes of RC building without and with yielding type X-shaped metallic damper are determined. The retrofitted reinforced concrete building is subjected to earthquake excitations and the response from the structure is recorded. This work discusses the preparation of test specimen, experimental set-up, instrumentation, method of testing of RC building and the response of the structure. The metallic damper reduces the time period of the structure and displacement demands on the OGS columns of the structure. Nonlinear time history analysis is performed using structural analysis package, SAP2000.

  15. On the validity of the classical hydrodynamic lubrication theory applied to squeeze film dampers

    International Nuclear Information System (INIS)

    Danaila, S; Moraru, L

    2010-01-01

    Squeeze film dampers (SFD) are devices utilized to control vibrations of the shafts of high-speed rotating machinery. The SFD - squirrel cage combination is probably the most used system for tuning the stiffness and damping of the supports for rotors installed on ball bearings. Squeeze film dampers are essentially hydrodynamic bearings which contain the ball bearings housings of ball-bearings supported shafts. Consequently, the oil film within the SFD are influenced only by the precession and nutation of the shaft, that is the flow of the oil within the damper is not directly influenced by the spin of the rotor. However, in the classical theory, the flow in the thin film is also governed by the Reynolds equation. In this paper, some of the limits of the classical theory of the SFD are discussed and theoretical and experimental studies, which illustrate the ideas presented herein, are presented as well. The orbits of an unbalanced rotor that is supported by a ball-bearings-SFD-squirrel-cage assembly at one end and by rigidly mounted ball bearings at the other end are computed using the bearing forces provided by the classical short bearing theory. The numerical model also includes the properties of the squirrel cage. The parameters of the squirrel cage were measured, together with the effect of the friction within the assembly. Experimental unbalance responses were also collected for various rotation speeds and unbalances to validate the numerical simulations.

  16. H∞ control of railway vehicle suspension with MR damper using scaled roller rig

    International Nuclear Information System (INIS)

    Shin, Yu-Jeong; You, Won-Hee; Hur, Hyun-Moo; Park, Joon-Hyuk

    2014-01-01

    In this paper, a magneto-rheological (MR) damper was applied to the secondary suspension to reduce the vibration of a car body. The control performance of the MR damper was verified by numerical analysis with a 1/5 scale railway vehicle model in accordance with the similarity law. The analysis results were then validated in tests. In particular, the objective of the study was to understand how the control performance affected the dynamic characteristics of a railway vehicle and to systematically analyze the relationship between control performance and dynamic characteristics depending on various running speeds. To achieve this, experimental results for the dynamic characteristics of the scaled MR damper designed for the 1/5 scale railway vehicle model were applied to the railway vehicle model. The H ∞ control method was applied to the controller. The means of designing the railway vehicle body vibration controller and the effectiveness of its results were studied. (paper)

  17. Mathematical model of a novel small magnetorheological damper by using outer magnetic field

    Directory of Open Access Journals (Sweden)

    Liutian Huang

    2017-03-01

    Full Text Available In order to realize small loading and small damping, a mini Magneto-rheological fluid (MRF damper is suggested by using new method of outer coils, and its physical model is established firstly. It was found that the landing force is only 1.74∼8N, the landing force is the third-order function with the current by polynomial fitting of the experimental data, which shows a force-current model. The results of force-displacement and force-velocity indicate that it has nonlinear hysteretic damping characteristics. Based on the new mini-mode principle and the damping characteristics, an improved nonlinear dynamics model is proposed, and its parameter expressions are obtained by parameter identification and regression fitting. Model curves fit well with experimental curves, and the improved model has fully demonstrated the dynamic characteristics of the mini-MRF damper. It will provide scientific method and physical model for the small MRF damper development.

  18. Viscous-Fluid-Spring Damper Retrofit of a Steel Moment Frame Structure

    International Nuclear Information System (INIS)

    Hussain, Saif; Van Benschoten, Paul; Al Satari, Mohamed; Lin, Silian

    2008-01-01

    The subject building is a peculiar pre-Northridge steel moment resisting frame building. Upon investigating the existing lateral resisting system, numerous significant deficiencies were identified; inherent lack of redundancy, poor geometry and inadequate stiffness of the lateral resisting system. All of which resulted in an extremely soft 5-story structure with a primary torsional mode of vibration at T 1 = 5.46 s. Significant structural modifications were deemed necessary to meet the ''life-safety'' performance objective as outlined in rehabilitation standards such as ASCE 41. Both increased stiffness and damping were required to adequately retrofit the building. Furthermore, adjacent building separation as well as deformation compatibility issues needed to be addressed and resolved. A three-dimensional computer model of the building was created using ETABS mathematically simulating the building's dynamic characteristics in its current condition. Multiple seismic retrofit systems were investigated such as Buckling Restrained Braced Frames (BRBF's). However, based on the performance effectiveness and constructability of the retrofit schemes studied, the Viscous-Fluid-Spring Damper (VFSD) system was proposed as the ''optimum'' solution for the building. The VFSD, was chosen because it combines the relatively compact size and minimally invasive constructability with the required properties (an elastomeric spring in parallel with a nonlinear velocity dependent viscous damper). A site-specific response spectrum was developed for the Design Basis Earthquake (DBE, 475 year return period) event, and three pairs of representative earthquake horizontal ground motion time-histories were scaled to match this DBE. The proposed scheme reduced the building maximum inter-story drift ratio from 5.4% to about 1%. Similarly, the maximum roof displacement was reduced by about 70% (23'' to 7'')

  19. Digital LLRF System for RFQ

    International Nuclear Information System (INIS)

    Agashe, Alok; Motiwala, P.D.; Bharade, S.K.; Mohan, Shyam; Joshi, Gopal; Das, D.

    2015-01-01

    A Low level RF (LLRF) system based on digital techniques has been developed for RFQ of Low Energy High Intensity Proton Accelerator (LEHIPA). The basic LLRF system for RFQ is composed of a Front end analog module housed in a 19 inch bin and a 6U cPCI based Digital board having a high speed and high density FPGA onboard, supporting 32 bit/33MHz PCI ver2.0 protocol and housed in a 19 inch cPCI crate. It also has a cPCI based CPU board with QNX operating system. The cPCI crate is connected to control room via Ethernet. Analog module conditions the input field signals from RF cavity and makes it compatible to digital board. It also amplifies RF Drive signal (Modulator output) from digital board, which goes to high power amplifier. The digital board digitally processes the input RF signals, and generates RF drive signal, which after amplification, used for driving the resonant cavity. The main features of digital board are under-sampling of input RF signals, digital in-phase and quadrature detection, and a proportional- integral (PI) controller algorithm implemented in a FPGA. The LLRF system works in CW as well as in PULSE mode. It also has a DDS implemented in VHDL, used for conditioning and tracking/tuning of the cavity. LLRF system operates under QNX based equipment frontend application and client running from control room. One analog module and one digital board set, supports one resonant cavity. The present paper describes the development of an LLRF system and its results with a test cavity. (author)

  20. Stability Analysis of a High-Speed Seal Test Rotor With Marginal and Extended Squeeze-Film Dampers: Theoretical and Experimental Results

    Science.gov (United States)

    Proctor, Margaret P.; Gunter, Edgar J.

    2007-01-01

    A case study of a high-speed seal test rotor shows how rotor dynamic analysis can be used to diagnose the source of high vibrations and evaluate a proposed remedy. Experimental results are compared with the synchronous and non-synchronous whirl response analysis of a double overhung, high-speed seal test rotor with ball bearings supported in 5.84- and 12.7-mm-long, un-centered squeeze-film oil dampers. Test performance with the original damper of length 5.84 mm was marginal. Non-synchronous whirling occurred at the overhung seal test disk and there was a high amplitude synchronous response near the drive spline above 32,000 rpm. Nonlinear synchronous unbalance and time transient whirl studies were conducted on the seal test rotor with the original and extended damper lengths. With the original damper design, the nonlinear synchronous response showed that unbalance could cause damper lockup at 33,000 rpm. Alford cross-coupling forces were also included at the overhung seal test disk for the whirl analysis. Sub-synchronous whirling at the seal test disk was observed in the nonlinear time transient analysis. With the extended damper length of 12.7 mm, the sub-synchronous motion was eliminated and the rotor unbalance response was acceptable to 45,000 rpm with moderate rotor unbalance. Seal test rotor orbits and vibration levels with the extended squeeze film dampers showed smooth operation to 40,444 rpm.

  1. Optimum Parameters of a Tuned Liquid Column Damper in a Wind Turbine Subject to Stochastic Load

    Science.gov (United States)

    Alkmim, M. H.; de Morais, M. V. G.; Fabro, A. T.

    2017-12-01

    Parameter optimization for tuned liquid column dampers (TLCD), a class of passive structural control, have been previously proposed in the literature for reducing vibration in wind turbines, and several other applications. However, most of the available work consider the wind excitation as either a deterministic harmonic load or random load with white noise spectra. In this paper, a global direct search optimization algorithm to reduce vibration of a tuned liquid column damper (TLCD), a class of passive structural control device, is presented. The objective is to find optimized parameters for the TLCD under stochastic load from different wind power spectral density. A verification is made considering the analytical solution of undamped primary system under white noise excitation by comparing with result from the literature. Finally, it is shown that different wind profiles can significantly affect the optimum TLCD parameters.

  2. Precision digital control systems

    Science.gov (United States)

    Vyskub, V. G.; Rozov, B. S.; Savelev, V. I.

    This book is concerned with the characteristics of digital control systems of great accuracy. A classification of such systems is considered along with aspects of stabilization, programmable control applications, digital tracking systems and servomechanisms, and precision systems for the control of a scanning laser beam. Other topics explored are related to systems of proportional control, linear devices and methods for increasing precision, approaches for further decreasing the response time in the case of high-speed operation, possibilities for the implementation of a logical control law, and methods for the study of precision digital control systems. A description is presented of precision automatic control systems which make use of electronic computers, taking into account the existing possibilities for an employment of computers in automatic control systems, approaches and studies required for including a computer in such control systems, and an analysis of the structure of automatic control systems with computers. Attention is also given to functional blocks in the considered systems.

  3. A spring-mass-damper system dynamics-based driver-vehicle integrated model for representing heterogeneous traffic

    Science.gov (United States)

    Munigety, Caleb Ronald

    2018-04-01

    The traditional traffic microscopic simulation models consider driver and vehicle as a single unit to represent the movements of drivers in a traffic stream. Due to this very fact, the traditional car-following models have the driver behavior related parameters, but ignore the vehicle related aspects. This approach is appropriate for homogeneous traffic conditions where car is the major vehicle type. However, in heterogeneous traffic conditions where multiple vehicle types are present, it becomes important to incorporate the vehicle related parameters exclusively to account for the varying dynamic and static characteristics. Thus, this paper presents a driver-vehicle integrated model hinged on the principles involved in physics-based spring-mass-damper mechanical system. While the spring constant represents the driver’s aggressiveness, the damping constant and the mass component take care of the stability and size/weight related aspects, respectively. The proposed model when tested, behaved pragmatically in representing the vehicle-type dependent longitudinal movements of vehicles.

  4. Analysis of the Multiple-Solution Response of a Flexible Rotor Supported on Non-Linear Squeeze Film Dampers

    Science.gov (United States)

    ZHU, C. S.; ROBB, D. A.; EWINS, D. J.

    2002-05-01

    The multiple-solution response of rotors supported on squeeze film dampers is a typical non-linear phenomenon. The behaviour of the multiple-solution response in a flexible rotor supported on two identical squeeze film dampers with centralizing springs is studied by three methods: synchronous circular centred-orbit motion solution, numerical integration method and slow acceleration method using the assumption of a short bearing and cavitated oil film; the differences of computational results obtained by the three different methods are compared in this paper. It is shown that there are three basic forms for the multiple-solution response in the flexible rotor system supported on the squeeze film dampers, which are the resonant, isolated bifurcation and swallowtail bifurcation multiple solutions. In the multiple-solution speed regions, the rotor motion may be subsynchronous, super-subsynchronous, almost-periodic and even chaotic, besides synchronous circular centred, even if the gravity effect is not considered. The assumption of synchronous circular centred-orbit motion for the journal and rotor around the static deflection line can be used only in some special cases; the steady state numerical integration method is very useful, but time consuming. Using the slow acceleration method, not only can the multiple-solution speed regions be detected, but also the non-synchronous response regions.

  5. Force control of a magnetorheological damper using an elementary hysteresis model-based feedforward neural network

    International Nuclear Information System (INIS)

    Ekkachai, Kittipong; Nilkhamhang, Itthisek; Tungpimolrut, Kanokvate

    2013-01-01

    An inverse controller is proposed for a magnetorheological (MR) damper that consists of a hysteresis model and a voltage controller. The force characteristics of the MR damper caused by excitation signals are represented by a feedforward neural network (FNN) with an elementary hysteresis model (EHM). The voltage controller is constructed using another FNN to calculate a suitable input signal that will allow the MR damper to produce the desired damping force. The performance of the proposed EHM-based FNN controller is experimentally compared to existing control methodologies, such as clipped-optimal control, signum function control, conventional FNN, and recurrent neural network with displacement or velocity inputs. The results show that the proposed controller, which does not require force feedback to implement, provides excellent accuracy, fast response time, and lower energy consumption. (paper)

  6. Extended neural network-based scheme for real-time force tracking with magnetorheological dampers

    DEFF Research Database (Denmark)

    Weber, Felix; Bhowmik, Subrata; Høgsberg, Jan Becker

    2014-01-01

    This paper validates numerically and experimentally a new neural network-based real-time force tracking scheme for magnetorheological (MR) dampers on a five-storey shear frame with MR damper. The inverse model is trained with absolute values of measured velocity and force because the targeted...... the pre-yield to the post-yield region. A control-oriented approach is presented to compensate for these drawbacks. The resulting control force tracking scheme is validated for the emulation of viscous damping, clipped viscous damping with negative stiffness, and friction damping with negative stiffness...

  7. Digital Dentistry — Digital Impression and CAD/CAM System Applications

    Directory of Open Access Journals (Sweden)

    Gabor Alin-Gabriel

    2017-03-01

    Full Text Available Digital imprint and computer-aided design/computer-aided manufacture (CAD/CAM systems offer several benefits compared to traditional techniques. The use of a CAD/CAM system to scan preparations and generate restorations in-office, removes a second appointment for the patient. The existence of precision benefits in using complete systems and chairside scanning systems, has been proven. CAD/CAM restorations have a good longevity and meet the accepted clinical parameters. New digital impression methods are presently accessible, and before long, the long-awaited goal of sparing patients of one the most unpleasant practices in clinical dentistry, acquiring dental impressions, will be exchanged by intraoral digital scanning. CAD/CAM systems existing nowadays, can feed data through accurate digital scans created from plaster models, straight to manufacturing systems that can shape ceramic or resin restorations with no requirement of a physical copy of the prepared, adjacent, and antagonist teeth.

  8. Digital processing data communication systems (bus systems)

    International Nuclear Information System (INIS)

    Fleck, K.

    1980-01-01

    After an introduction to the technology of digital processing data communication systems there are the following chapters: digital communication of processing data in automation technology, the technology of biserial communication, the implementaiton of a bus system, the data transmission of the TDC-2000 system of Honeywell's and the process bus CS 275 in the automation system TELEPERM M of Siemens AG. (WB) [de

  9. The LHC Transverse Damper (ADT) Performance Specification

    CERN Document Server

    Boussard, Daniel; Linnecar, Trevor Paul R; CERN. Geneva. SPS and LEP Division

    1997-01-01

    The appended document specifies the performance of the transverse damper (ADT) for the LHC. As Annex 1 of the Addendum No.1 to the Protocol of April 18, 1997; it forms part of the 1992 co-operation agreement between CERN and JINR (Dubna, Russia) concerning its participation in the LHC project. The current text is a reprint of the original version. Changes that have been agreed upon are inserted as footnotes.

  10. On the nonlinear design of industrial arc spring dampers

    DEFF Research Database (Denmark)

    Lahriri, Said; Santos, Ilmar; Hartmann, Henning

    2011-01-01

    The objective of this paper is to present a numerical approach for analyzing parameter excited vibrations on a gas compressor, induced by the nonlinear characteristic of the arc spring feature of certain designs of squeeze film dampers, SFDs. The behavior of the journal is studied in preparation...

  11. HOM Dampers or not in Superconducting RF Proton Linacs

    CERN Document Server

    Tückmantel, Joachim

    2009-01-01

    Circular machines are plagued by Coupled Bunch Instabilities, driven by impedance peaks, irrespectively of their frequency relation to machine lines; hence all cavity Higher Order Modes are possible drivers. This is the fundamental reason that all superconducting RF cavities in circular machines are equipped with HOM dampers. This raises the question if HOM damping would not be imperative also in high current proton linacs where a mechanism akin to CBI might exist. To clarify this question we have simulated the longitudinal bunched beam dynamics in linacs, allowing bunch-to-bunch variations in time-of-arrival. Simulations were executed for a generic proton linac with properties close to SNS or the planned SPL at CERN. It was found that for monopole HOMs with high Qext large beam scatter or even beam loss cannot be excluded. Therefore omitting HOM dampers on superconducting RF cavities in high current proton linacs, even pulsed ones, is a very risky decision.

  12. HOM Dampers or not in SUPERCONDUCTING RF Proton Linacs

    CERN Document Server

    Tückmantel, Joachim

    2009-01-01

    Circular machines are plagued by Coupled Bunch Instabilities, driven by impedance peaks, irrespectively of their frequency relation to machine lines; hence all cavity Higher Order Modes are possible drivers. This is the fundamental reason that all superconducting RF cavities in circular machines are equipped with HOM dampers. This raises the question if HOM damping would not be imperative also in high current proton linacs where a mechanism akin to CBI might exist. To clarify this question we have simulated the longitudinal bunched beam dynamics in linacs, allowing bunch-to-bunch variations in time-of-arrival. Simulations were executed for a generic proton linac with properties close to SNS or the planned SPL at CERN. It was found that for monopole HOMs with high Qext large beam scatter or even beam loss cannot be excluded. Therefore omitting HOM dampers on superconducting RF cavities in high current proton linacs, even pulsed ones, is a very risky decision.

  13. Nonlinear modeling of a rotational MR damper via an enhanced Bouc–Wen model

    International Nuclear Information System (INIS)

    Miah, Mohammad S; Chatzi, Eleni N; Dertimanis, Vasilis K; Weber, Felix

    2015-01-01

    The coupling of magnetorheological (MR) dampers with semi-active control schemes has proven to be an effective and failsafe approach for vibration mitigation of low-damped structures. However, due to the nonlinearities inherently relating to such damping devices, the characterization of the associated nonlinear phenomena is still a challenging task. Herein, an enhanced phenomenological modeling approach is proposed for the description of a rotational-type MR damper, which comprises a modified Bouc–Wen model coupled with an appropriately selected sigmoid function. In a first step, parameter optimization is performed on the basis of individual models in an effort to approximate the experimentally observed response for varying current levels and actuator force characteristics. In a second step, based on the previously identified parameters, a generalized best-fit model is proposed by performing a regression analysis. Finally, model validation is carried out via implementation on different sets of experimental data. The proposed model indeed renders an improved representation of the actually observed nonlinear behavior of the tested rotational MR damper. (paper)

  14. Experimental and analytical study on vibration control effects of eddy-current tuned mass dampers under seismic excitations

    Science.gov (United States)

    Lu, Zheng; Huang, Biao; Zhang, Qi; Lu, Xilin

    2018-05-01

    Eddy-current tuned mass dampers (EC-TMDs) are non-contacting passive control devices and are developed on the basis of conventional tuned mass dampers. They comprise a solid mass, a stiffness element, and a damping element, wherein the damping mechanism originates from eddy currents. By relative motion between a non-magnetic conductive metal and a permanent magnet in a dynamic system, a time-varying magnetic field is induced in the conductor, thereby generating eddy currents. The eddy currents induce a magnetic field with opposite polarity, causing repulsive forces, i.e., damping forces. This technology can overcome the drawbacks of conventional tuned mass dampers, such as limited service life, deterioration of mechanical properties, and undesired additional stiffness. The experimental and analytical study of this system installed on a multi-degree-of-freedom structure is presented in this paper. A series of shaking table tests were conducted on a five-story steel-frame model with/without an EC-TMD to evaluate the effectiveness and performance of the EC-TMD in suppressing the vibration of the model under seismic excitations. The experimental results show that the EC-TMD can effectively reduce the displacement response, acceleration response, interstory drift ratio, and maximum strain of the columns under different earthquake excitations. Moreover, an analytical method was proposed on the basis of electromagnetic and structural dynamic theories. A comparison between the test and simulation results shows that the simulation method can be used to estimate the response of structures with an EC-TMD under earthquake excitations with acceptable accuracy.

  15. Application of mathematical model for high viscous damper to dynamic analysis of NPP pipings

    International Nuclear Information System (INIS)

    Kostarev, V.V.; Bercovsky, A.M.; Kireev, O.B.; Vasiliev, P.S.

    1993-01-01

    The problems of dynamic analysis of Nuclear Power Plants (NPP) piping systems are considered in the paper. The special calculation program for PC has been developed that enables to estimate the seismic margin for any piping system with different antiseismic devices having nonlinear characteristics. The calculated comparison has been done for two antiseismic supports that are widely used now, namely: a High Viscous Damper (HVD) and a Seismic Stop Support (SSS) with the application, as an example, to the well known pipeline BM3 (USNRC). (author)

  16. Application of mathematical model for high viscous damper to dynamic analysis of NPP pipings

    Energy Technology Data Exchange (ETDEWEB)

    Kostarev, V V; Bercovsky, A M; Kireev, O B; Vasiliev, P S [CKTI VIBROSEISM (CVS), St. Petersburg (Russian Federation)

    1993-07-01

    The problems of dynamic analysis of Nuclear Power Plants (NPP) piping systems are considered in the paper. The special calculation program for PC has been developed that enables to estimate the seismic margin for any piping system with different antiseismic devices having nonlinear characteristics. The calculated comparison has been done for two antiseismic supports that are widely used now, namely: a High Viscous Damper (HVD) and a Seismic Stop Support (SSS) with the application, as an example, to the well known pipeline BM3 (USNRC). (author)

  17. Elastomeric Dampers derived from First-Principles-Based Analytical Simulation, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — Lead-lag motions of rotor blades in helicopters require damping to stabilize them. In practice, this has necessitated the use of external hydraulic dampers which...

  18. A study of influence of material properties on magnetic flux density induced in magneto rheological damper through finite element analysis

    Directory of Open Access Journals (Sweden)

    Gurubasavaraju T. M.

    2018-01-01

    Full Text Available Magnetorheological fluids are smart materials, which are responsive to the external stimulus and changes their rheological properties. The damper performance (damping force is dependent on the magnetic flux density induced at the annular gap. Magnetic flux density developed at fluid flow gap of MR damper due to external applied current is also dependent on materials properties of components of MR damper (such as piston head, outer cylinder and piston rod. The present paper discus about the influence of different materials selected for components of the MR damper on magnetic effect using magnetostatic analysis. Different materials such as magnetic and low carbon steels are considered for piston head of the MR damper and magnetic flux density induced at fluid flow gap (filled with MR fluid is computed for different DC current applied to the electromagnetic coil. Developed magnetic flux is used for calculating the damper force using analytical method for each case. The low carbon steel has higher magnetic permeability hence maximum magnetic flux could pass through the piston head, which leads to higher value of magnetic effect induction at the annular gap. From the analysis results it is observed that the magnetic steel and low carbon steel piston head provided maximum magnetic flux density. Eventually the higher damping force can be observed for same case.

  19. Elastomeric Dampers Derived From First-Principles-Based Analytical Simulation, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — The lead-lag motions of rotor blades in a helicopter require damping to stabilize them. In practice, this has necessitated the use of external hydraulic dampers...

  20. Vibration control of bridge subjected to multi-axle vehicle using multiple tuned mass friction dampers

    Science.gov (United States)

    Pisal, Alka Y.; Jangid, R. S.

    2016-06-01

    The effectiveness of tuned mass friction damper (TMFD) in reducing undesirable resonant response of the bridge subjected to multi-axle vehicular load is investigated. A Taiwan high-speed railway (THSR) bridge subjected to Japanese SKS (Salkesa) train load is considered. The bridge is idealized as a simply supported Euler-Bernoulli beam with uniform properties throughout the length of the bridge, and the train's vehicular load is modeled as a series of moving forces. Simplified model of vehicle, bridge and TMFD system has been considered to derive coupled differential equations of motion which is solved numerically using the Newmark's linear acceleration method. The critical train velocities at which the bridge undergoes resonant vibration are investigated. Response of the bridge is studied for three different arrangements of TMFD systems, namely, TMFD attached at mid-span of the bridge, multiple tuned mass friction dampers (MTMFD) system concentrated at mid-span of the bridge and MTMFD system with distributed TMFD units along the length of the bridge. The optimum parameters of each TMFD system are found out. It has been demonstrated that an optimized MTMFD system concentrated at mid-span of the bridge is more effective than an optimized TMFD at the same place with the same total mass and an optimized MTMFD system having TMFD units distributed along the length of the bridge. However, the distributed MTMFD system is more effective than an optimized TMFD system, provided that TMFD units of MTMFD system are distributed within certain limiting interval and the frequency of TMFD units is appropriately distributed.

  1. Digital System Reliability Test for the Evaluation of safety Critical Software of Digital Reactor Protection System

    Directory of Open Access Journals (Sweden)

    Hyun-Kook Shin

    2006-08-01

    Full Text Available A new Digital Reactor Protection System (DRPS based on VME bus Single Board Computer has been developed by KOPEC to prevent software Common Mode Failure(CMF inside digital system. The new DRPS has been proved to be an effective digital safety system to prevent CMF by Defense-in-Depth and Diversity (DID&D analysis. However, for practical use in Nuclear Power Plants, the performance test and the reliability test are essential for the digital system qualification. In this study, a single channel of DRPS prototype has been manufactured for the evaluation of DRPS capabilities. The integrated functional tests are performed and the system reliability is analyzed and tested. The results of reliability test show that the application software of DRPS has a very high reliability compared with the analog reactor protection systems.

  2. Higher-order-mode damper as beam-position monitors; Higher-Order-Mode Daempfer als Stahllagemonitore

    Energy Technology Data Exchange (ETDEWEB)

    Peschke, C.

    2006-03-15

    In the framework of this thesis a beam-position monitor was developed, which can only because of the signals from the HOM dampers of a linear-accelerator structure determine the beam position with high accuracy. For the unique determination of the beam position in the plane a procedure was developed, which uses the amplitudes and the start-phase difference between a dipole mode and a higher monopole mode. In order tocheck the suitability of the present SBLC-HOM damper as beam position monitor three-dimensional numerical field calculations in the frequency and time range and measurements on the damper cell were performed. For the measurements without beam a beam simulator was constructed, which allows computer-driven measurements with variable depositions of the simulated beam with a resolution of 1.23 {mu}m. Because the complete 6 m long, 180-cell accelerator structure was not available for measurements and could also with the available computers not be three-dimensionally simulated simulated, a one-dimensional equivalent-circuit based model of the multi-cell was studied. The equivalent circuits with 879 concentrated components regards the detuning from cell to cell, the cell losses, the damper losses, and the beam excitation in dependence on the deposition. the measurements and simulations let a resolution of the ready beam-position monitor on the 180-cell in the order of magnitude of 1-10 {mu}m and a relative accuracy smaller 6.2% be expected.

  3. Digital control systems. Verteilte Prozessleitsysteme

    Energy Technology Data Exchange (ETDEWEB)

    1984-01-01

    With a distinct description of the systems properties thin regulation shall provide a latter transparency for the use of digital control systems. The application of the new technique shall be facilitated, incitations for the further development shall be given and the compatibility of the systems shall be advanced. Moreover, the regulation can be used as criteria catalogue for the evaluation of digital systems.

  4. Analysis and calibration of the noise voltage between the damper plates used for beam diffusion during the crystal extraction experiment

    CERN Document Server

    Gyr, Marcel; Klem, J T; Louwerse, R; Milstead, I

    1995-01-01

    The analogue noise signal produced by a WAVETEK function generator, which is used to excite one of the horizontal dampers BDH 21437 or BDH 21451 for blowing up the beam during the crystal extraction MDs, has been analysed to determine its r.m.s. value as a function of the selected attenuation. The input/output characteristics of damper Nº 2 (BDH 21451) has been measured in order to calibrate the r.m.s. kicks (diffusion speed) which a particle experiences on its passage through the damper.

  5. The damper for the transverse instabilities of the SPS

    CERN Document Server

    Bossart, Rudolf; Gareyte, Jacques; de Raad, Bastiaan; Rossi, V

    1979-01-01

    For beam intensities above 10/sup 12/ protons per pulse in the SPS, collective transverse beam instabilities develop with frequencies between 15 kHz and 3 MHz because of the resistive wall effect of the vacuum chamber. An active feedback system with an electrostatic deflector has been installed in the SPS for damping the resistive wall instabilities in both the vertical and horizontal planes. Measurements have been made to determine the threshold and growth rate of these instabilities. As a novel application, the damper can be used also for the excitation of small coherent betatron oscillations. A phase-locked loop tracks the beam oscillations and provides a continuous display of the betatron wave-number Q during the cycle. (4 refs).

  6. Digital fluorographic method and system

    International Nuclear Information System (INIS)

    Ledley, R.S.

    1985-01-01

    This invention relates to a digital fluorographic method and system, in particular a method and system which calls for the digitization and storage of first and second x-ray picture data derived before and after injection of a contrast medium into a subject. The digitized pictures are stored in separate memories in an associated system, and can be separately whole-picture processed to develop corresponding processed picture data. The resulting data are subtractively combined to produce data corresponding to a pictorial representation of differences between the x-ray picture before and after injection of the contrast medium

  7. The rheology of shear thickening fluid (STF) and the dynamic performance of an STF-filled damper

    International Nuclear Information System (INIS)

    Zhang, X Z; Li, W H; Gong, X L

    2008-01-01

    This paper presents a study of the rheological properties of shear thickening fluid (STF) and its application as a damper. The STF samples, with different weight fractions, were prepared by dispersing nanosized silica particles in a solvent. By using a parallel-plate rheometer, both steady-state and dynamic experiments were carried out to investigate the rheological properties of STFs. Experimental results indicated that these suspensions show an abrupt increase in complex viscosity beyond a critical dynamic shear rate, as well as this increase being reversible. Working with the fabricated STF materials, a prototype damper was fabricated and its dynamic performances were experimentally evaluated. An equivalent linear model through effective elastic stiffness and viscous damping was developed to address both the damping and the stiffness capabilities of the damper. Also, a mathematical model was developed to investigate working mechanisms of STF-based devices

  8. Nonlinear modeling of tuned liquid dampers (TLDs) in rotating wind turbine blades for damping edgewise vibrations

    DEFF Research Database (Denmark)

    Zhang, Zili; Nielsen, Søren R. K.; Basu, Biswajit

    2015-01-01

    Tuned liquid dampers (TLDs) utilize the sloshing motion of the fluid to suppress structural vibrations and become a natural candidate for damping vibrations in rotating wind turbine blades. The centrifugal acceleration at the tip of a wind turbine blade can reach a magnitude of 7–8g. This facilit......Tuned liquid dampers (TLDs) utilize the sloshing motion of the fluid to suppress structural vibrations and become a natural candidate for damping vibrations in rotating wind turbine blades. The centrifugal acceleration at the tip of a wind turbine blade can reach a magnitude of 7–8g...... free-surface elevation equally well, the one-mode model can still be utilized for the design of TLD. Parametric optimization of the TLD is carried out based on the one-mode model, and the optimized damper effectively improves the dynamic response of wind turbine blades....

  9. Experience of digital control systems in Scandinavian BWRs

    International Nuclear Information System (INIS)

    Rydahl, I.

    1989-01-01

    Since 1984 digital control systems have been in operation in various Scandinavian BWRs. Examples of such digital control systems are: dual microprocessor based system for complete control of radwaste plant, three channel recirculation control system, and three channel feedwater control system. This paper describes Swedish development from one channel through three channel analog control systems to digital systems. The author describes experience of digital control systems during design, testing, commissioning and operation. The main benefits of digital compared with analog technology are discussed. Especially the outstanding facility of using a built-in process simulator for commissioning and tuning. The use of digital technology in nuclear safety system and future plans are dealt with

  10. Effect of Temperature and Electric Field on the Damping and Stiffness Characteristics of ER Fluid Short Squeeze Film Dampers

    Directory of Open Access Journals (Sweden)

    H. P. Jagadish

    2013-01-01

    Full Text Available Squeeze film dampers are novel rotor dynamic devices used to alleviate small amplitude, large force vibrations and are used in conjunction with antifriction bearings in aircraft jet engine bearings to provide external damping as these possess very little inherent damping. Electrorheological (ER fluids are controllable fluids in which the rheological properties of the fluid, particularly viscosity, can be controlled in accordance with the requirements of the rotor dynamic system by controlling the intensity of the applied electric field and this property can be utilized in squeeze film dampers, to provide variable stiffness and damping at a particular excitation frequency. The paper investigates the effect of temperature and electric field on the apparent viscosity and dynamic (stiffness and damping characteristics of ER fluid (suspension of diatomite in transformer oil using the available literature. These characteristics increase with the field as the viscosity increases with the field. However, these characteristics decrease with increase in temperature and shear strain rate as the viscosity of the fluid decreases with temperature and shear strain rate. The temperature is an important parameter as the aircraft jet engine rotors are located in a zone of high temperature gradients and the damper fluid is susceptible to large variations in temperature.

  11. Optimal design of nuclear mechanical dampers with analytical hierarchy process

    International Nuclear Information System (INIS)

    Zou Yuehua; Wen Bo; Xu Hongxiang; Qin Yonglie

    2000-01-01

    An optimal design with analytical hierarchy process on nuclear mechanical dampers manufactured by authors' university was described. By using fuzzy judgement matrix the coincidence was automatically satisfied without the need of coincidence test. The results obtained by this method have been put into the production practices

  12. Optimal damper placement research

    Science.gov (United States)

    Smirnov, Vladimir; Kuzhin, Bulat

    2017-10-01

    Nowadays increased noise and vibration pollution on technopark and research laboratories territories, which is negatively influencing on production of high-precision measuring instruments. The problem is actual for transport hubs, which experience influence of machines, vehicles, trains and planes. Energy efficiency is one of major functions in modern road transport development. The problem of environmental pollution, lack of energy resources and energy efficiency requires research, production and implementation of energy efficient materials that would be the foundation of environmentally sustainable transport infrastructure in road traffic. Improving the efficiency of energy use is a leading option to gain better energy security, improve industry profitability and competitiveness, and reduce the overall energy sector impacts on climate change. This paper has next indirect goals. Research impact of vibration on constructions, such as bus and train stations, terminals, which are mostly exposed to oscillation. Extend the buildings operation by decreasing the negative influence. Reduce expenses on maintenance and repair works. It is important not to forget about seismic protection, which is actual nowadays, when the safety stands first. Analysis of devastating earthquakes for last few years proves reasonableness of application such systems. The article is dedicated to learning dependence of damper location on natural frequency. As a model for analyze was simulated concrete construction with variable profile. We used program complex Patran for analyzing the model.

  13. Effects of the lower extremities muscle activation during muscular strength training on an unstable platform with magneto-rheological dampers

    Science.gov (United States)

    Piao, YongJun; Choi, YounJung; Kim, JungJa; Kwan, TaeKyu; Kim, Nam-Gyun

    2009-03-01

    Adequate postural balance depends on the spatial and temporal integration of vestibular, visual, and somatosensory information. Especially, the musculoskeletal function (range of joint, flexibility of spine, muscular strength) is essential in maintaining the postural balance. Muscular strength training methods include the use of commercialized devices and repeatable resistance training tools (rubber band, ball, etc). These training systems cost high price and can't control of intensity. Thus we suggest a new training system which can adjust training intensity and indicate the center of pressure of a subject while the training was passively controlled by applying controlled electric current to the Magneto- Rheological damper. And we performed experimental studies on the muscular activities in the lower extremities during maintaining, moving and pushing exercises on an unstable platform with Magneto rheological dampers. A subject executed the maintaining, moving and pushing exercises which were displayed in a monitor. The electromyographic signals of the eight muscles in lower extremities were recorded and analyzed in the time and frequency domain: the muscles of interest were rectus femoris, biceps femoris, tensor fasciae latae, vastus lateralis, vastus medialis, gastrocnemius, tibialis anterior, and soleus. The experimental results showed the difference of muscular activities at the four moving exercises and the nine maintaining exercises. The rate of the increase in the muscular activities was affected by the condition of the unstable platform with MR dampers for the maintaining and moving exercises. The experimental results suggested the choice of different maintaining and moving exercises could selectively train different muscles with varying intensity. Furthermore, the findings also suggested the training using this system can improve the ability of postural balance.

  14. Digital control system of advanced reactor

    International Nuclear Information System (INIS)

    Peng Huaqing; Zhang Rui; Liu Lixin

    2001-01-01

    This article produced the Digital Control System For Advanced Reactor made by NPIC. This system uses Siemens SIMATIC PCS 7 process control system and includes five control system: reactor power control system, pressurizer level control system, pressurizer pressure control system, steam generator water level control system and dump control system. This system uses three automatic station to realize the function of five control system. Because the safety requisition of reactor is very strict, the system is redundant. The system configuration uses CFC and SCL. the human-machine interface is configured by Wincc. Finally the system passed the test of simulation by using RETRAN 02 to simulate the control object. The research solved the key technology of digital control system of reactor and will be very helpful for the nationalization of digital reactor control system

  15. Design and modeling of semi-active squeeze film dampers using magneto-rheological fluids

    International Nuclear Information System (INIS)

    Kim, Keun-Joo; Lee, Chong-Won; Koo, Jeong-Hoi

    2008-01-01

    Conventional squeeze film dampers (SFDs) have shown their effectiveness in suppressing unbalanced vibrations in rotor systems, particularly supported by rolling element bearings. Recently, there is an increasing demand for 'controllable' SFDs to meet the need of modern rotating machinery, characterized by high operating speed and high load capacity. Thus, this paper presents a controllable semi-active SFD using magneto-rheological (MR) fluids, focusing on its design and modeling. It offers a comprehensive design method and an innovative experimental identification and modeling technique for MR-SFDs. The primary goal of the MR-SFD design is set to maximize its dynamic control bandwidth, and the design method includes the material selection, magnetic circuit analysis and sealing element design. After constructing a prototype MR-SFD based on the final design, this work investigated how some of the critical design parameters affect the performance of the MR-SFD (i.e. its dynamic control bandwidth change). Furthermore, it characterized the damper's dynamic behavior experimentally using a novel excitation method that adopts active magnetic bearing (AMB) units. Unlike conventional methods, the AMB system was able to precisely control the amplitude and frequency of the input excitation, enabling us to obtain the nonlinear dynamic stiffness properties of the MR-SFD with varying input current. In modeling the dynamic behavior of the MR-SFD, this study employed the describing function method. The describing function analysis effectively captured the nonlinear dynamic behavior of the MR-SFD

  16. Digital System Categorization Methodology to Support Integration of Digital Instrumentation and Control Models into PRAs

    International Nuclear Information System (INIS)

    Arndt, Steven A.

    2011-01-01

    It has been suggested that by categorizing the various digital systems used in safety critical applications in nuclear power plants, it would be possible to determine which systems should be modeled in the analysis of the larger plant wide PRA, at what level of detail the digital system should be modeled and using which methods. The research reported in this paper develops a categorization method using system attributes to permit a modeler to more effectively model the systems that will likely have the most critical contributions to the overall plant safety and to more effectively model system interactions for those digital systems where the interactions are most important to the overall accuracy and completeness of the plant PRA. The proposed methodology will categorize digital systems based on certain attributes of the systems themselves and how they will be used in the specific application. This will help determine what digital systems need to be modeled and at what level of detail, and can be used to guide PRA analysis and regulatory reviews. The three-attribute categorization strategy that was proposed by Arndt is used as the basis for the categorization methodology developed here. The first attribute, digital system complexity, is based on Type Il interactions defined by Aldemir and an overall digital system size and complexity index. The size and complexity index used are previously defined software complexity metrics. Potential sub-attributes of digital system complexity include, design complexity, software complexity, hardware complexity, system function complexity and testability. The second attribute, digital system interactions/inter-conductivity, is a combination of Rushby's coupling and Ademir's Type I interactions. Digital systems that are loosely coupled and/or have very few Type I interaction would not interact dynamically with the overall system and would have a low interactions/inter-conductivity score. Potential sub-attributes of digital system

  17. Digital System Categorization Methodology to Support Integration of Digital Instrumentation and Control Models into PRAs

    Energy Technology Data Exchange (ETDEWEB)

    Arndt, Steven A. [U.S. Nuclear Regulatory Commission, Washington D.C. (United States)

    2011-08-15

    It has been suggested that by categorizing the various digital systems used in safety critical applications in nuclear power plants, it would be possible to determine which systems should be modeled in the analysis of the larger plant wide PRA, at what level of detail the digital system should be modeled and using which methods. The research reported in this paper develops a categorization method using system attributes to permit a modeler to more effectively model the systems that will likely have the most critical contributions to the overall plant safety and to more effectively model system interactions for those digital systems where the interactions are most important to the overall accuracy and completeness of the plant PRA. The proposed methodology will categorize digital systems based on certain attributes of the systems themselves and how they will be used in the specific application. This will help determine what digital systems need to be modeled and at what level of detail, and can be used to guide PRA analysis and regulatory reviews. The three-attribute categorization strategy that was proposed by Arndt is used as the basis for the categorization methodology developed here. The first attribute, digital system complexity, is based on Type Il interactions defined by Aldemir and an overall digital system size and complexity index. The size and complexity index used are previously defined software complexity metrics. Potential sub-attributes of digital system complexity include, design complexity, software complexity, hardware complexity, system function complexity and testability. The second attribute, digital system interactions/inter-conductivity, is a combination of Rushby's coupling and Ademir's Type I interactions. Digital systems that are loosely coupled and/or have very few Type I interaction would not interact dynamically with the overall system and would have a low interactions/inter-conductivity score. Potential sub-attributes of

  18. Development of digital safety system logic and control

    International Nuclear Information System (INIS)

    Nishikawa, H.; Sakamoto, H.

    1995-01-01

    Advanced-BWR (ABWR) uses total digital control and instrumentation (C and I) system. In particular, ABWR adopts a newly developed safety system using advanced digital technology. In the presentation the digital safety system design, manufacturing and factory validation test method are shortly overviewed. The digital safety system consists of micro-processor based digital controllers, data and information transmission by optical fibers and human-machine interface using color flat displays. This new developed safety system meet the nuclear safety requirements such as high reliability, independence of divisions, operability and maintainability. (2 refs., 4 figs., 1 tab.)

  19. Digital I and C system upgrade integration technique

    Energy Technology Data Exchange (ETDEWEB)

    Huang, H. W. [Inst. of Nuclear Energy Research (INER), No. 1000, Wenhua Road, Chiaan Village, Longtan Township, Taoyuan County, 32546, Taiwan (China); Shih, C. [Inst. of Nuclear Engineering and Science, National Tsing Hua Univ., 101, Sec. 2, Kuang Fu Rd, Hsinchu, Taiwan (China); Wang, J. R. [Inst. of Nuclear Energy Research (INER), No. 1000, Wenhua Road, Chiaan Village, Longtan Township, Taoyuan County, 32546, Taiwan (China); Huang, K. C. [Inst. of Nuclear Engineering and Science, National Tsing Hua Univ., 101, Sec. 2, Kuang Fu Rd, Hsinchu, Taiwan (China)

    2012-07-01

    This work developed an integration technique for digital I and C system upgrade, the utility can replace the I and C systems step by step systematically by this method. Inst. of Nuclear Energy Research (INER) developed a digital Instrumentation and Control (I and C) replacement integration technique on the basis of requirement of the three existing nuclear power plants (NPPs), which are Chin-Shan (CS) NPP, Kuo-Sheng (KS) NPP, and Maanshan (MS) NPP, in Taiwan, and also developed the related Critical Digital Review (CDR) Procedure. The digital I and C replacement integration technique includes: (I) Establishment of Nuclear Power Plant Digital Replacement Integration Guideline, (2) Preliminary Investigation on I and C System Digitalization, (3) Evaluation on I and C System Digitalization, and (4) Establishment of I and C System Digitalization Architectures. These works can be a reference for performing I and C system digital replacement integration of the three existing NPPs of Taiwan Power Company (TPC). A CDR is the review for a critical system digital I and C replacement. The major reference of this procedure is EPRI TR- 1011710 (2005) 'Handbook for Evaluating Critical Digital Equipment and Systems' which was published by the Electric Power Research Inst. (EPRI). With this document, INER developed a TPC-specific CDR procedure. Currently, CDR becomes one of the policies for digital I and C replacement in TPC. The contents of this CDR procedure include: Scope, Responsibility, Operation Procedure, Operation Flow Chart, CDR review items. The CDR review items include the comparison of the design change, Software Verification and Validation (SVandV), Failure Mode and Effects Analysis (FMEA), Evaluation of Diversity and Defense-in-depth (D3), Evaluation of Watchdog Timer, Evaluation of Electromagnetic Compatibility (EMC), Evaluation of Grounding for System/Component, Seismic Evaluation, Witness and Inspection, Lessons Learnt from the Digital I and C Failure

  20. Digital I and C system upgrade integration technique

    International Nuclear Information System (INIS)

    Huang, H. W.; Shih, C.; Wang, J. R.; Huang, K. C.

    2012-01-01

    This work developed an integration technique for digital I and C system upgrade, the utility can replace the I and C systems step by step systematically by this method. Inst. of Nuclear Energy Research (INER) developed a digital Instrumentation and Control (I and C) replacement integration technique on the basis of requirement of the three existing nuclear power plants (NPPs), which are Chin-Shan (CS) NPP, Kuo-Sheng (KS) NPP, and Maanshan (MS) NPP, in Taiwan, and also developed the related Critical Digital Review (CDR) Procedure. The digital I and C replacement integration technique includes: (I) Establishment of Nuclear Power Plant Digital Replacement Integration Guideline, (2) Preliminary Investigation on I and C System Digitalization, (3) Evaluation on I and C System Digitalization, and (4) Establishment of I and C System Digitalization Architectures. These works can be a reference for performing I and C system digital replacement integration of the three existing NPPs of Taiwan Power Company (TPC). A CDR is the review for a critical system digital I and C replacement. The major reference of this procedure is EPRI TR- 1011710 (2005) 'Handbook for Evaluating Critical Digital Equipment and Systems' which was published by the Electric Power Research Inst. (EPRI). With this document, INER developed a TPC-specific CDR procedure. Currently, CDR becomes one of the policies for digital I and C replacement in TPC. The contents of this CDR procedure include: Scope, Responsibility, Operation Procedure, Operation Flow Chart, CDR review items. The CDR review items include the comparison of the design change, Software Verification and Validation (SVandV), Failure Mode and Effects Analysis (FMEA), Evaluation of Diversity and Defense-in-depth (D3), Evaluation of Watchdog Timer, Evaluation of Electromagnetic Compatibility (EMC), Evaluation of Grounding for System/Component, Seismic Evaluation, Witness and Inspection, Lessons Learnt from the Digital I and C Failure Events. A

  1. Modems for emerging digital cellular-mobile radio system

    Science.gov (United States)

    Feher, Kamilo

    1991-01-01

    Digital modem techniques for emerging digital cellular telecommunications-mobile radio system applications are described and analyzed. In particular, theoretical performance, experimental results, principles of operation, and various architectures of pi/4-QPSK (pi/4-shifted coherent or differential QPSK) modems for second-generation US digital cellular radio system applications are presented. The spectral/power efficiency and performance of the pi/4-QPSK modems (American and Japanese digital cellular emerging standards) are studied and briefly compared to GMSK (Gaussian minimum-shift keying) modems (proposed for European DECT and GSM cellular standards). Improved filtering strategies and digital pilot-aided (digital channel sounding) techniques are also considered for pi/4-QPSK and other digital modems. These techniques could significantly improve the performance of digital cellular and other digital land mobile and satellite mobile radio systems. More spectrally efficient modem trends for future cellular/mobile (land mobile) and satellite communication systems applications are also highlighted.

  2. Analysis and testing of an inner bypass magnetorheological damper for shock and vibration mitigation

    Science.gov (United States)

    Bai, Xian-Xu; Hu, Wei; Wereley, Norman M.

    2013-04-01

    Aiming at fundamentally improving the performance of MR dampers, including maximizing dynamic range (i.e., ratio of field-on to field-off damping force) while simultaneously minimizing field-off damping force, this study presents the principle of an inner bypass magnetorheological damper (IBMRD). The IBMRD is composed of a pair of twin tubes, i.e., the inner tube and outer concentric tube, a movable piston-shaft arrangement, and an annular MR fluid flow gap sandwiched between the concentric tubes. In the IBMRD, the inner tube serves simultaneously as the guide for the movable piston and the bobbin for the electromagnetic coil windings, and five active rings on the inner tube, annular MR fluid flow gap, and outer tube forms five closed magnetic circuits. The annular fluid flow gap is an inner bypass annular valve where the rheology of the MR fluids, and hence the damping force of the MR damper, is controlled. Based on the structural principle of the IBMRD, the IBMRD is configured and its finite element analysis (FEA) is implemented. After theoretically constructing the hydro-mechanical model for the IBMRD, its mathematical model is established using a Bingham-plastic nonlinear fluid model. The characteristics of the IBMRD are theoretically evaluated and compared to those of a conventional piston-bobbin MR damper with an identical active length and cylinder diameter. In order to validate the theoretical results predicted by the mathematical model, the prototype IBMRD is designed, fabricated, and tested. The servo-hydraulic testing machine (type: MTS 810) and rail-guided drop tower are used to provide sinusoidal displacement excitation and shock excitation to the IBMRD, respectively.

  3. Digital image information systems in radiology

    International Nuclear Information System (INIS)

    Greinacher, C.F.C.; Luetke, B.; Seufert, G.

    1987-01-01

    About 25% of all patient examinations are performed digitally in a today's radiological department. A computerized system is described that supports generation, transport, interpretation and archiving of digital radiological images (Picture Archiving and Communication System PACS). The technical features concerning image communication via local area networks, image storage on magnetic and optical media and digital workstations for image display and manipulation are described. A structured system architecture is introduced. It allows flexible adaption to individual organizations and minimizes the requirements of the communication network. (orig.) [de

  4. Certification of digital system software

    International Nuclear Information System (INIS)

    Waclo, J.; Cook, B.; Adomaitis, D.

    1991-01-01

    The activities involved in the successful application of digital systems to Nuclear Protection functions is not achieved through happenstance. At Westinghouse there has been a longstanding program to utilize digital state of the art technology for protection system advancement. Thereby gaining the advantages of increased system reliability, performance, ease of operation and reduced maintenance costs. This paper describes the Westinghouse background and experience in the safety system software development process, including Verification and Validation, and its application to protection system qualification and the successful use for licensing the Eagle 21 Digital Process Protection System Upgrade. In addition, the lessons learned from this experience are discussed from the perspective of improving the development process through applying feedback of the measurements made on the process and the software product quality. The goal of this process optimization is to produce the highest possible software quality while recognizing the real world constraints of available resources, project schedule and the regulatory policies that are customary in the nuclear industry

  5. Lessons learned in digital upgrade projects digital control system implementation at US nuclear power stations

    International Nuclear Information System (INIS)

    Kelley, S.; Bolian, T. W.

    2006-01-01

    AREVA NP has gained significant experience during the past five years in digital upgrades at operating nuclear power stations in the US. Plants are seeking modernization with digital technology to address obsolescence, spare parts availability, vendor support, increasing age-related failures and diminished reliability. New systems offer improved reliability and functionality, and decreased maintenance requirements. Significant lessons learned have been identified relating to the areas of licensing, equipment qualification, software quality assurance and other topics specific to digital controls. Digital control systems have been installed in non safety-related control applications at many utilities within the last 15 years. There have also been a few replacements of small safety-related systems with digital technology. Digital control systems are proving to be reliable, accurate, and easy to maintain. Digital technology is gaining acceptance and momentum with both utilities and regulatory agencies based upon the successes of these installations. Also, new plants are being designed with integrated digital control systems. To support plant life extension and address obsolescence of critical components, utilities are beginning to install digital technology for primary safety-system replacement. AREVA NP analyzed operating experience and lessons learned from its own digital upgrade projects as well as industry-wide experience to identify key issues that should be considered when implementing digital controls in nuclear power stations

  6. Development of prototype digital LLRF system at RRCAT

    International Nuclear Information System (INIS)

    Tiwari, Nitesh; Bagduwal, Pritam S.; Sharma, Dheeraj; Chakraborty, Shoubhik; Lad, Mahendra; Hannurkar, P.R.

    2013-01-01

    RF field is used in accelerator to accelerate the charge particles. The beam parameters depend highly on the stability of the RF field. Due to dynamic beam loading conditions the variations in RF parameters of accelerating structures needs to be controlled precisely, hence low level RF feedback control system plays vital role. Considering revolutionary development in the field of digital electronics and inherent advantages of digital systems, digital LLRF control system work was taken up. The digital LLRF system consists of two major units namely RF processing and digital processing. RF processing unit uses I/Q modulator for amplitude and phase control. This unit provides synchronized clock using ÷16 pre-scalar and also performs up conversion and down conversion for synchronized LO and IF generation respectively, along with required amplification and filtering. Digital processing unit takes down converted IF signal with appropriate sampling rate for I/Q detection. To extract the amplitude and phase information I/Q data is digitally filtered and processed using CORDIC algorithm in FPGA. I/Q modulator is used for controlling the amplitude and phase of RF field. Prototype development of digital LLRF control system for 325 MHz, 650 MHz is in progress. Digital LLRF system at 505 MHz has been installed in one RF station of Indus-2 RF system. In this paper development of prototype Digital LLRF system at RFSD, Raja Ramanna Centre for Advanced Technology and results are presented. (author)

  7. Experimental and analytical studies on multiple tuned mass dampers for seismic protection of porcelain electrical equipment

    Science.gov (United States)

    Bai, Wen; Dai, Junwu; Zhou, Huimeng; Yang, Yongqiang; Ning, Xiaoqing

    2017-10-01

    Porcelain electrical equipment (PEE), such as current transformers, is critical to power supply systems, but its seismic performance during past earthquakes has not been satisfactory. This paper studies the seismic performance of two typical types of PEE and proposes a damping method for PEE based on multiple tuned mass dampers (MTMD). An MTMD damping device involving three mass units, named a triple tuned mass damper (TTMD), is designed and manufactured. Through shake table tests and finite element analysis, the dynamic characteristics of the PEE are studied and the effectiveness of the MTMD damping method is verified. The adverse influence of MTMD redundant mass to damping efficiency is studied and relevant equations are derived. MTMD robustness is verified through adjusting TTMD control frequencies. The damping effectiveness of TTMD, when the peak ground acceleration far exceeds the design value, is studied. Both shake table tests and finite element analysis indicate that MTMD is effective and robust in attenuating PEE seismic responses. TTMD remains effective when the PGA far exceeds the design value and when control deviations are considered.

  8. Studi Eksperimen Aliran Melalui Square Duct dan Square Elbow 90º dengan Double Guide Vane pada Variasi Sudut Bukaan Damper

    Directory of Open Access Journals (Sweden)

    Andrew Jaya Nazar

    2017-01-01

    Full Text Available Instalasi saluran udara tidak hanya berupa pipa lurus, tetapi juga terdapat fitting/aksesoris perpipaan misalnya elbow 90o dan damper. Aksesoris perpipaan ini berfungsi agar saluran udara dapat terpasang sesuai dengan kebutuhan. Namun, penggunaan aksesoris perpipaan ini menyebabkan bertambahnya pressure drop akibat adanya friction loss dan separation loss. Pemasangan guide vane pada elbow 90o diharapkan dapat mengurangi pressure drop karena dapat mengurangi terjadinya secondary flow, namun hal ini dapat menambah kerugian akibat gaya gesek. Saat ini penghematan energi menjadi sorotan terutama dalam dunia industri. Penurunan pressure drop pada belokan perpipaan sangat diharapkan, agar dapat menghemat energi lebih. Untuk itu perlu dilakukan usaha agar dapat menurunkan pressure drop yang terjadi. Penelitian ini dilakukan secara eksperimen dengan benda uji saluran udara yang terdiri dari: upstream duct (straight duct, square elbow 90o dengan r/Dh=1,5 dan dilengkapi double guide vane, damper, downstream duct (straight duct, dan induced fan. Pengukuran parameter yang dibutuhkan dilakukan dengan menggunakan: pitot tube, inclined manometer, pressure tranducer. Dari eksperimen ini diperoleh bahwa profil kecepatan pada masing-masing variasi sudut bukaan damper sudah mendekati keadaan recovery aliran pada akhir section baik dari bidang vertikal maupun horizontal. Pressure drop yang terjadi semakin naik seiring dengan bertambahnya nilai bilangan Reynolds dan sudut bukaan damper. Nilai konstanta damper semakin naik dari bukaan sudut 0o hingga 30o.

  9. Robust digital controllers for uncertain chaotic systems: A digital redesign approach

    Energy Technology Data Exchange (ETDEWEB)

    Ababneh, Mohammad [Department of Controls, FMC Kongsberg Subsea, FMC Energy Systems, Houston, TX 77067 (United States); Barajas-Ramirez, Juan-Gonzalo [CICESE, Depto. De Electronica y Telecomunicaciones, Ensenada, BC, 22860 (Mexico); Chen Guanrong [Centre for Chaos Control and Synchronization, Department of Electronic Engineering, City University of Hong Kong (China); Shieh, Leang S. [Department of Electrical and Computer Engineering, University of Houston, Houston, TX 77204-4005 (United States)

    2007-03-15

    In this paper, a new and systematic method for designing robust digital controllers for uncertain nonlinear systems with structured uncertainties is presented. In the proposed method, a controller is designed in terms of the optimal linear model representation of the nominal system around each operating point of the trajectory, while the uncertainties are decomposed such that the uncertain nonlinear system can be rewritten as a set of local linear models with disturbed inputs. Applying conventional robust control techniques, continuous-time robust controllers are first designed to eliminate the effects of the uncertainties on the underlying system. Then, a robust digital controller is obtained as the result of a digital redesign of the designed continuous-time robust controller using the state-matching technique. The effectiveness of the proposed controller design method is illustrated through some numerical examples on complex nonlinear systems--chaotic systems.

  10. Analysis of the partially filled viscous ring damper. [application as nutation damper for spinning satellite

    Science.gov (United States)

    Alfriend, K. T.

    1973-01-01

    A ring partially filled with a viscous fluid has been analyzed as a nutation damper for a spinning satellite. The fluid has been modelled as a rigid slug of finite length moving in a tube and resisted by a linear viscous force. It is shown that there are two distinct modes of motion, called the spin synchronous mode and the nutation synchronous mode. Time constants for each mode are obtained for both the symmetric and asymmetric satellite. The effects of a stop in the tube and an offset of the ring from the spin axis are also investigated. An analysis of test results is also given including a determination of the effect of gravity on the time constants in the two modes.

  11. Stability Investigations of Rotors Mounted on Hybrid Magnetorheological Dampers by the Evolutive Method

    Czech Academy of Sciences Publication Activity Database

    Zapoměl, Jaroslav; Kozánek, Jan; Ferfecki, Petr

    2014-01-01

    Roč. 21, č. 2 (2014), s. 75-81 ISSN 1802-1484 Institutional support: RVO:61388998 Keywords : rigid rotors * controllable damping * hybrid magnetorheological dampers * vibration stability Subject RIV: BI - Acoustics

  12. imulasi Numerik Aliran Tiga Dimensi Melalui Rectangular Duct dengan Variasi Bukaan Damper

    Directory of Open Access Journals (Sweden)

    Edo Edgar Santosa

    2016-04-01

    Full Text Available Dalam  sistem saluran  terdapat banyak penggunaan elbow dan assesoris lain yang akan menyebabkan terjadinya kerugian tekanan pada aliran. Hal tersebut  disebabkan karena adanya perubahan arah aliran fluida yang melalui saluran tersebut. Nilai penurunan tekanan (pressure drop pada aliran yang melalui suattu saluran dipengaruhi oleh besarnya laju aliran pada inlet, serta radius kelengkungan dari elbow yang akan menyebabkan aliran sekunder kemudian timbul aliran vortex. Hal ini berakibat kerugian energi (headloss yang lebih besar. Peletakan bodi pengganggu dan pemasangan elbow dimaksudkan untuk melihat fenomena aliran di sekitar bodi pengganggu Model uji yang akan digunakan di dalam studi ini berupa rectangular duct yang pada bagian inlet terpasang elbow 90o dengan damper yang diletakkan pada jarak x/Dh=2. Fluida kerjanya adalah udara yang mengalir secara incompressible, viscous, steady dan mempunyai profil kecepatan uniform pada sisi inlet dengan dua variasi bilangan Reynolds yaitu 2.05 x 105 dan 8.2 x 105serta empat pengaturan sudut bodi pengganggu 0o, 10o, 20o, dan 30o Penelitian dilakukan secara  numerik 3D  menggunakan piranti lunak Computation Fluid Dynamics (CFD komersial dengan model turbulensi k-ε Realizable. Hasil studi ini diperoleh bahwa proses recovery aliran dipengaruhi oleh sudut bukaan damper, untuk variasi sudut bukaan damper 30°. Dengan sudut bukaan 30° terjadi percepatan aliran pada daerah dekat dinding yang berakibat bertambahnya momentum aliran sehingga mempercepat proses recovery aliran dan aliran sekunder pada daerah dekat dinding dapat teratasi.

  13. Retrofit of Ressalat jacket platform (Persian Gulf) using friction damper device

    DEFF Research Database (Denmark)

    Komachi, Y.; Tabeshpour, M. R.; Golafshani, A. A.

    2011-01-01

    A friction damper device (FDD) is used for vibration control of an existing steel jacket platform under seismic excitation. First, the damping is presented for vibration mitigation of structures located in seismically active zones. A new method for quick design of friction or yielding damping dev...

  14. Digital systems from logic gates to processors

    CERN Document Server

    Deschamps, Jean-Pierre; Terés, Lluís

    2017-01-01

    This textbook for a one-semester course in Digital Systems Design describes the basic methods used to develop “traditional” Digital Systems, based on the use of logic gates and flip flops, as well as more advanced techniques that enable the design of very large circuits, based on Hardware Description Languages and Synthesis tools. It was originally designed to accompany a MOOC (Massive Open Online Course) created at the Autonomous University of Barcelona (UAB), currently available on the Coursera platform. Readers will learn what a digital system is and how it can be developed, preparing them for steps toward other technical disciplines, such as Computer Architecture, Robotics, Bionics, Avionics and others. In particular, students will learn to design digital systems of medium complexity, describe digital systems using high level hardware description languages, and understand the operation of computers at their most basic level. All concepts introduced are reinforced by plentiful illustrations, examples, ...

  15. Research on magnetorheological damper suspension with permanent magnet and magnetic valve based on developed FOA-optimal control algorithm

    Energy Technology Data Exchange (ETDEWEB)

    Xiao, Ping; Gao, Hong [Anhui Polytechnic University, Wuhu (China); Niu, Limin [Anhui University of Technology, Maanshan (China)

    2017-07-15

    Due to the fail safe problem, it was difficult for the existing Magnetorheological damper (MD) to be widely applied in automotive suspensions. Therefore, permanent magnets and magnetic valves were introduced to existing MDs so that fail safe problem could be solved by the magnets and damping force could be adjusted easily by the magnetic valve. Thus, a new Magnetorheological damper with permanent magnet and magnetic valve (MDPMMV) was developed and MDPMMV suspension was studied. First of all, mechanical structure of existing magnetorheological damper applied in automobile suspensions was redesigned, comprising a permanent magnet and a magnetic valve. In addition, prediction model of damping force was built based on electromagnetics theory and Bingham model. Experimental research was onducted on the newly designed damper and goodness of fit between experiment results and simulated ones by models was high. On this basis, a quarter suspension model was built. Then, fruit Fly optimization algorithm (FOA)-optimal control algorithm suitable for automobile suspension was designed based on developing normal FOA. Finally, simulation experiments and bench tests with input surface of pulse road and B road were carried out and the results indicated that working erformance of MDPMMV suspension based on FOA-optimal control algorithm was good.

  16. Digital BPM Systems for Hadron Accelerators

    CERN Document Server

    Belleman, J; Kasprowicz, G; Raich, U

    2009-01-01

    The CERN Proton Synchrotron has been fitted with a new trajectory measurement system (TMS). Analogue signals from forty beam position monitors are digitized at 125MS/s, and then further treated entirely in the digital domain to derive the positions of all individual particle bunches on the fly. Large FPGAs handle all digital processing. The system fits in fourteen plug-in modules distributed over three half-width cPCI crates. Data are stored in circular buffers of large enough size to keep a fewseconds-worth of position data. Multiple clients can then request selected portions of the data, possibly representing many thousands of consecutive turns, for display on operator consoles. The system uses digital phase-locked loops to derive its beamlocked timing reference. Programmable state machines, driven by accelerator timing pulses and information from the accelerator control system, direct the order of operations. The cPCI crates are connected to a standard Linux computer by means of a private Gigabit Ethernet ...

  17. Fully integrated digital GAMMA camera-computer system

    International Nuclear Information System (INIS)

    Berger, H.J.; Eisner, R.L.; Gober, A.; Plankey, M.; Fajman, W.

    1985-01-01

    Although most of the new non-nuclear imaging techniques are fully digital, there has been a reluctance in nuclear medicine to abandon traditional analog planar imaging in favor of digital acquisition and display. The authors evaluated a prototype digital camera system (GE STARCAM) in which all of the analog acquisition components are replaced by microprocessor controls and digital circuitry. To compare the relative effects of acquisition matrix size on image quality and to ascertain whether digital techniques could be used in place of analog imaging, Tc-99m bone scans were obtained on this digital system and on a comparable analog camera in 10 patients. The dedicated computer is used for camera setup including definition of the energy window, spatial energy correction, and spatial distortion correction. The display monitor, which is used for patient positioning and image analysis, is 512/sup 2/ non-interlaced, allowing high resolution imaging. Data acquisition and processing can be performed simultaneously. Thus, the development of a fully integrated digital camera-computer system with optimized display should allow routine utilization of non-analog studies in nuclear medicine and the ultimate establishment of fully digital nuclear imaging laboratories

  18. REVIEW OF NRC APPROVED DIGITAL CONTROL SYSTEMS ANALYSIS

    International Nuclear Information System (INIS)

    Markman, D.W.

    1999-01-01

    Preliminary design concepts for the proposed Subsurface Repository at Yucca Mountain indicate extensive reliance on modern, computer-based, digital control technologies. The purpose of this analysis is to investigate the degree to which the U. S. Nuclear Regulatory Commission (NRC) has accepted and approved the use of digital control technology for safety-related applications within the nuclear power industry. This analysis reviews cases of existing digitally-based control systems that have been approved by the NRC. These cases can serve as precedence for using similar types of digitally-based control technologies within the Subsurface Repository. While it is anticipated that the Yucca Mountain Project (YMP) will not contain control systems as complex as those required for a nuclear power plant, the review of these existing NRC approved applications will provide the YMP with valuable insight into the NRCs review process and design expectations for safety-related digital control systems. According to the YMP Compliance Program Guidance, portions of various NUREGS, Regulatory Guidelines, and nuclear IEEE standards the nuclear power plant safety related concept would be applied to some of the designs on a case-by-case basis. This analysis will consider key design methods, capabilities, successes, and important limitations or problems of selected control systems that have been approved for use in the Nuclear Power industry. An additional purpose of this analysis is to provide background information in support of further development of design criteria for the YMP. The scope and primary objectives of this analysis are to: (1) Identify and research the extent and precedence of digital control and remotely operated systems approved by the NRC for the nuclear power industry. Help provide a basis for using and relying on digital technologies for nuclear related safety critical applications. (2) Identify the basic control architecture and methods of key digital control

  19. System Reduction and Damping of Flexible Structures

    DEFF Research Database (Denmark)

    Høgsberg, Jan Riess; Krenk, Steen

    2007-01-01

    An increasing number of flexible structures such as cable-stayed bridges, pedestrian bridges and high-rise buildings are fitted with local dampers to mitigate vibration problems. In principle the effect of local dampers can be analyzed by use of complex modes, e.g. in conjunction with an averaging...... technique for local linearization of the damper characteristics. However, the complex mode shapes and frequencies depend on the magnitude of the damper and therefore are less suitable for design of the damper system. An efficient alternative consists in the use of a two-component representation...... of the damped modes of the structure. The idea is to represent the damped mode as a linear combination of the modes that occur in two distinctly different situations representing extreme conditions: the mode shape of the structure without the damper(s), and the mode shape of the structure, when the damper...

  20. Creation of a Cell-Based Digital Cadastral Mapping System (Digital ...

    African Journals Online (AJOL)

    Digital cadastre enhances land transaction activities to be conducted in a business manner. Similarly, land subdivision or boundary redefinition, land registration and land marketing are achieved with better accuracy. This paper discusses the need to introduce a national Cell-Based Digital Cadastral Mapping System model ...

  1. Mixed Skyhook and FxLMS Control of a Half-Car Model with Magnetorheological Dampers

    Directory of Open Access Journals (Sweden)

    Piotr Krauze

    2016-01-01

    Full Text Available The problem of vibration attenuation in a semiactive vehicle suspension is considered. The proposed solution is based on usage of the information about the road roughness coming from the sensor installed on the front axle of the vehicle. It does not need any preview sensor to measure the road roughness as other preview control strategies do. Here, the well-known Skyhook algorithm is used for control of the front magnetorheological (MR damper. This algorithm is tuned to a quarter-car model of the front part of the vehicle. The rear MR damper is controlled by the FxLMS (Filtered-x LMS taking advantage of the information about the motion of the front vehicle axle. The goal of this algorithm is to minimize pitch of the vehicle body. The strategy is applied for a four-degree-of-freedom (4-DOF vehicle model equipped with magnetorheological dampers which were described using the Bouc-Wen model. The suspension model was subjected to the road-induced excitation in the form of a series of bumps within the frequency range 1.0–10 Hz. Different solutions are compared based on the transmissibility function and simulation results show the usefulness of the proposed solution.

  2. Digital Components in Swedish NPP Power Systems

    International Nuclear Information System (INIS)

    Karlsson, Mattias; Eriksson, Tage

    2015-01-01

    Swedish nuclear power plants have over the last 20 years of operation modernised or exchanged several systems and components of the electrical power system. Within these works, new components based on digital technology have been employed in order to realize functionality that was previously achieved by using electro-mechanical or analogue technology. Components and systems such as relay protection, rectifiers, inverters, variable speed drives and diesel-generator sets are today equipped with digital components. Several of the systems and components fulfil functions with a safety-role in the NPP. Recently, however, a number of incidents have occurred which highlight deficiencies in the design or HMI of the equipment, which warrants questions whether there are generic problems with some applications of digital components that needs to be addressed. The use of digital components has presented cost effective solutions, or even the only available solution on the market enabling a modernisation. The vast majority of systems using digital components have been operating without problems and often contribute to improved safety but the challenge of non-detectable, or non-identifiable, failure modes remain. In this paper, the extent to which digital components are used in Swedish NPP power systems will be presented including a description of typical applications. Based on data from maintenance records and fault reports, as well as interviews with designers and maintenance personnel, the main areas where problems have been encountered and where possible risks have been identified will be described. The paper intends to investigate any 'tell-tales' that could give signals of unwanted behaviour. Furthermore, particular benefits experienced by using digital components will be highlighted. The paper will also discuss the safety relevance of these findings and suggest measures to improve safety in the application of digital components in power systems. (authors)

  3. Improved reliability of wind turbine towers with active tuned mass dampers (ATMDs)

    Science.gov (United States)

    Fitzgerald, Breiffni; Sarkar, Saptarshi; Staino, Andrea

    2018-04-01

    Modern multi-megawatt wind turbines are composed of slender, flexible, and lightly damped blades and towers. These components exhibit high susceptibility to wind-induced vibrations. As the size, flexibility and cost of the towers have increased in recent years, the need to protect these structures against damage induced by turbulent aerodynamic loading has become apparent. This paper combines structural dynamic models and probabilistic assessment tools to demonstrate improvements in structural reliability when modern wind turbine towers are equipped with active tuned mass dampers (ATMDs). This study proposes a multi-modal wind turbine model for wind turbine control design and analysis. This study incorporates an ATMD into the tower of this model. The model is subjected to stochastically generated wind loads of varying speeds to develop wind-induced probabilistic demand models for towers of modern multi-megawatt wind turbines under structural uncertainty. Numerical simulations have been carried out to ascertain the effectiveness of the active control system to improve the structural performance of the wind turbine and its reliability. The study constructs fragility curves, which illustrate reductions in the vulnerability of towers to wind loading owing to the inclusion of the damper. Results show that the active controller is successful in increasing the reliability of the tower responses. According to the analysis carried out in this paper, a strong reduction of the probability of exceeding a given displacement at the rated wind speed has been observed.

  4. Design and damping force characterization of a new magnetorheological damper activated by permanent magnet flux dispersion

    Science.gov (United States)

    Lee, Tae-Hoon; Han, Chulhee; Choi, Seung-Bok

    2018-01-01

    This work proposes a novel type of tunable magnetorheological (MR) damper operated based solely on the location of a permanent magnet incorporated into the piston. To create a larger damping force variation in comparison with the previous model, a different design configuration of the permanent-magnet-based MR (PMMR) damper is introduced to provide magnetic flux dispersion in two magnetic circuits by utilizing two materials with different magnetic reluctance. After discussing the design configuration and some advantages of the newly designed mechanism, the magnetic dispersion principle is analyzed through both the formulated analytical model of the magnetic circuit and the computer simulation based on the magnetic finite element method. Sequentially, the principal design parameters of the damper are determined and fabricated. Then, experiments are conducted to evaluate the variation in damping force depending on the location of the magnet. It is demonstrated that the new design and magnetic dispersion concept are valid showing higher damping force than the previous model. In addition, a curved structure of the two materials is further fabricated and tested to realize the linearity of the damping force variation.

  5. Development and validation of novel digitalized cervicography system

    Science.gov (United States)

    Kim, Soo-Nyung; Kim, Yun Hwan; Nam, Kye-Hyun; Lee, Seon-Kyung; Lee, Tae Sung; Choi, Ho-Sun; Han, Sei-Jun

    2016-01-01

    Objective Digital cervicography systems would be expected to reduce the costs of film cervicography, and provide the opportunity for "telemedicine-based" screening. We aimed to develop web-based digital cervicography system, and validate it compared with conventional film cervicography. Methods A hundred cases from five centers were prospectively included, and cervical images (analogue, digitalized by scanning analogue, and digital) were taken separately using both analogue (Cerviscope) and digital camera (Dr. Cervicam) in each patient. Nine specialists evaluated the three kinds of images of each case with time interval between evaluations of each image. To validate novel digitalized system, we analyzed intra-observer variance among evaluation results of three kinds of images. Results Sixty-three cases were finally analyzed after excluding technically defective cases that cannot be evaluable on analogue images. The generalized kappa for analogue versus digital image was 0.83, for analogue versus scanned image 0.72, and for digital versus scanned image was 0.71; all were in excellent consensus. Conclusion Digitalized cervicography system can be substituted for the film cervicography very reliably, and can be used as a promising telemedicine tool for cervical cancer screening. PMID:27200314

  6. Digital mineral logging system

    International Nuclear Information System (INIS)

    West, J.B.

    1980-01-01

    A digital mineral logging system acquires data from a mineral logging tool passing through a borehole and transmits the data uphole to an electronic digital signal processor. A predetermined combination of sensors, including a deviometer, is located in a logging tool for the acquisition of the desired data as the logging tool is raised from the borehole. Sensor data in analog format is converted in the logging tool to a digital format and periodically batch transmitted to the surface at a predetermined sampling rate. An identification code is provided for each mineral logging tool, and the code is transmitted to the surface along with the sensor data. The self-identifying tool code is transmitted to the digital signal processor to identify the code against a stored list of the range of numbers assigned to that type of tool. The data is transmitted up the d-c power lines of the tool by a frequency shift key transmission technique. At the surface, a frequency shift key demodulation unit transmits the decoupled data to an asynchronous receiver interfaced to the electronic digital signal processor. During a recording phase, the signals from the logging tool are read by the electronic digital signal processor and stored for later processing. During a calculating phase, the stored data is processed by the digital signal processor and the results are outputted to a printer or plotter, or both

  7. Control system of digital x-ray systems by quality parameters

    International Nuclear Information System (INIS)

    Balashov, S.V.; Kovalenko, Yu.N.

    2013-01-01

    The paper proposed a control system of X-ray digital equipment on quality indicators. Two basic parameters were determined: image quality and patients' radiation load. A method for monitoring these indicators is proposed. The criterion of equipment suitability is to obtain control digital X-ray images of diagnostically acceptable quality at a fixed low entrance dose in the plane of the digital detector. It is shown that the control system of X-ray digital equipment based on indicators of quality is the most appropriate in situations of deficit of financial resources, since minimizing the costs for the purchase and running of control systems, does not require highly skilled technical personnel, and reduces the duration of the equipment inspection. (authors)

  8. Digital processing data communication systems (bus systems). Digitale Prozessdaten-Kommunikations-Systeme (Bus Systeme)

    Energy Technology Data Exchange (ETDEWEB)

    Fleck, K

    1980-01-01

    After an introduction to the technology of digital processing data communication systems there are the following chapters: digital communication of processing data in automation technology, the technology of biserial communication, the implementaiton of a bus system, the data transmission of the TDC-2000 system of Honeywell's and the process bus CS 275 in the automation system TELEPERM M of Siemens AG.

  9. Improving total-building seismic performance using linear fluid viscous dampers

    OpenAIRE

    Del Gobbo, GM; Blakeborough, A; Williams, MS

    2018-01-01

    Previous research has revealed that Eurocode-compliant structures can experience structural and nonstructural damage during earthquakes. Retrofitting buildings with fluid viscous dampers (FVDs) can improve interstorey drifts and floor accelerations, two structural parameters that characterize seismic demand. Previous research focusing on FVD applications for improving seismic performance has focused on structural performance. Structural parameters such as interstorey drifts and floor accelera...

  10. Development of digital low level rf system

    International Nuclear Information System (INIS)

    Michizono, Shinichiro; Anami, Shozo; Katagiri, Hiroaki; Fang, Zhigao; Matsumoto, Toshihiro; Miura, Takako; Yano, Yoshiharu; Yamaguchi, Seiya; Kobayashi, Tetsuya

    2008-01-01

    One of the biggest advantages of the digital low level rf (LLRF) system is its flexibility. Owing to the recent rapid progress in digital devices (such as ADCs and DACs) and telecommunication devices (mixers and IQ modulators), digital LLRF system becomes popular in these 10 years. The J-PARC linac LLRF system adopted cPCI crates and FPGA based digital feedback system. Since the LLRF control of the normal conducting cavities are more difficult than super conducting cavities due to its lower Q values, fast processing using the FPGA was the essential to the feedback control. After the successful operation of J-PARC linac LLRF system, we developed the STF (ILC test facility in KEK) LLRF system. Since the klystron drives eight cavities in STF phase 1, we modified the FPGA board. Basic configuration and the performances of these systems are summarized. The future R and D projects (ILC and ERL) is also described from the viewpoints of LLRF. (author)

  11. High Density Digital Data Storage System

    Science.gov (United States)

    Wright, Kenneth D., II; Gray, David L.; Rowland, Wayne D.

    1991-01-01

    The High Density Digital Data Storage System was designed to provide a cost effective means for storing real-time data from the field-deployable digital acoustic measurement system. However, the high density data storage system is a standalone system that could provide a storage solution for many other real time data acquisition applications. The storage system has inputs for up to 20 channels of 16-bit digital data. The high density tape recorders presently being used in the storage system are capable of storing over 5 gigabytes of data at overall transfer rates of 500 kilobytes per second. However, through the use of data compression techniques the system storage capacity and transfer rate can be doubled. Two tape recorders have been incorporated into the storage system to produce a backup tape of data in real-time. An analog output is provided for each data channel as a means of monitoring the data as it is being recorded.

  12. Re-tuning tuned mass dampers using ambient vibration measurements

    International Nuclear Information System (INIS)

    Hazra, B; Sadhu, A; Narasimhan, S; Lourenco, R

    2010-01-01

    Deterioration, accidental changes in the operating conditions, or incorrect estimates of the structure modal properties lead to de-tuning in tuned mass dampers (TMDs). To restore optimal performance, it is necessary to estimate the modal properties of the system, and re-tune the TMD to its optimal state. The presence of closely spaced modes and a relatively large amount of damping in the dominant modes renders the process of identification difficult. Furthermore, the process of estimating the modal properties of the bare structure using ambient vibration measurements of the structure with the TMD is challenging. In order to overcome these challenges, a novel identification and re-tuning algorithm is proposed. The process of identification consists of empirical mode decomposition to separate the closely spaced modes, followed by the blind identification of the remaining modes. Algorithms for estimating the fundamental frequency and the mode shape of the primary structure necessary for re-tuning the TMD are proposed. Experimental results from the application of the proposed algorithms to identify and re-tune a laboratory structure TMD system are presented

  13. The role of the fire dampers in the event of fire in a nuclear facility. Selection criteria for devices

    International Nuclear Information System (INIS)

    Savornin, J.; Laborde, J.C.

    1989-10-01

    In nuclear facilities, where unacceptable quantities of radioactive aerosols could be spread in the event of a fire, the ventilation system must be designed so that an underpressure is maintained under such circumstances. This is the reason why the extracting ventilation of the room in which the fire has broken out has generally to be kept going as long as possible. This prevents smoke and radioactive aerosols from spreading to accessways and adjacent rooms. Consequently, the various devices of the ventilation network need to have high fire resistance. Fire dampers can be applied to exhaust air to delay the heat build-up of a major fire. Specialized qualification testing is required for these dampers. The criteria we have used as a basis for specifying the required qualities of installations are defined. The tests that have been performed, or are now in progress, are described. The results obtained so far are given. Devices and arrangements are suggested

  14. Pilot Study for Investigating the Cyclic Response of the Recentering Bridge Bearing System Combined with the Friction Damper

    Directory of Open Access Journals (Sweden)

    Jong Wan Hu

    2016-01-01

    Full Text Available The bridge bearing is one of the component members which provide resting supports between piers and decks. The bridge bearing is intended to control longitudinal movement caused by traffic flow and thermal expansion, thereby reducing stress concentration. In high seismicity area, the bridge bearing has been utilized as the base isolation system to mitigate acceleration transferred from the ground. Although the existing bridge bearing installed between superstructure and substructure provides extra flexibility to the base of the entire structure, considerable permanent deformation occurs due to lack of recentering capacity after earthquake. It is required to spend extra cost for repairing impaired parts. The bridge bearings integrated with superelastic shape memory alloy (SMA devices used for upgrading the recentering effect into the friction damper are proposed in this study. The refined finite element (FE analyses are introduced to reproduce the response of such new structures under cyclic loading condition. The bridge bearing systems that maintain uniform recentering capability are designed with various friction coefficients so as to examine energy dissipation and residual deformation through FE analyses. After observing FE analysis results, optimal design for the recentering bridge bearing system will be proposed to take advantage of energy dissipation and self-centering capacity.

  15. Digital subtraction angiography system evaluation with phantoms

    International Nuclear Information System (INIS)

    Wenstrup, R.S.; Sweeney, K.P.; Scholz, F.J.

    1985-01-01

    Advances in digital subtraction angiography imaging demonstrate the need for critical evaluation of the performance of digital subtraction equipment. The design of a phantom set for noninvasive assessment of the imaging quality of digital subtraction equipment is described; components include a remotely controlled transport system and individual patterns to evaluate the contrast and detail properties of the image intensifier, low-contrast sensitivity and resolution of the system, geometric distortion of image, linearity, mechanical and electronic stability of equipment, and effects of bone and bowel gas on iodine perception. The performance of an add-on digital radiographic system is presented, along with radiation exposure levels at the image intensifier for a range of radiographic techniques

  16. Adaptation of high viscous dampers (HVD) for essential decreasing of in-structure floor response spectra

    International Nuclear Information System (INIS)

    Kostarev, V.V.; Petrenko, A.V.; Vasilyev, P.S.; Reinsch, K.-H.

    2005-01-01

    This paper concerns a further development of High Viscous Damper (HVD) approach for essential decreasing of structure's floor response spectra. Usually restraining of components and pipelines by HVD is used for significant decreasing of operational vibration and seismic loads. A new approach consists of dampers installation for essential upgrading of a whole system's damping that is much more efficient in both technical and economical points of view than restraining of each component of the system. In that way using of HVD means high energy dissipation for whole dynamic system 'Building-Components' subjected to the base seismic or other extreme load excitation. The specific feature of each NPP site is an existing of a few closely spaced buildings: reactor building, turbine hall and so on. As the rule such buildings play sufficiently different roles in NPP operation and therefore have sufficiently different design, natural frequencies (periods) and distortion of floors and different rocking modes on a soil. The main idea explained in the paper is an interconnection of buildings by HVD. Then differences in their mechanical properties provide their out-of-phase relative motions during an earthquake and therefore effective dissipative work provided by HVD devices. At the same time implementation of HVD approach allows to eliminate possible interactions and collisions in the gaps between building structures that wears potential threat of building failure. The detailed 3D finite element models of reactor building, turbine hall and special building were developed for NPP with VVER-1000 MWt reactor type. Performed analysis has shown high efficiency of suggested approach for protection of buildings, structures, systems and components against seismic and other impacts. (authors)

  17. Effect of magneto rheological damper on tool vibration during hard turning

    Science.gov (United States)

    Paul, P. Sam; Varadarajan, A. S.

    2012-12-01

    Recently, the concept of hard turning has gained considerable attention in metal cutting as it can apparently replace the traditional process cycle of turning, heat treating, and finish grinding for assembly of hard wear resistant steel parts. The present investigation aims at developing a magneto rheological (MR) fluid damper for suppressing tool vibration and promoting better cutting performance during hard turning. The magneto rheological Fluid acts as a viscoelastic spring with non-linear vibration characteristics that are controlled by the composition of the magneto rheological fluid, the shape of the plunger and the electric parameters of the magnetizing field. Cutting experiments were conducted to arrive at a set of electrical, compositional and shape parameters that can suppress tool vibration and promote better cutting performance during turning of AISI 4340 steel of 46 HRC with minimal fluid application using hard metal insert with sculptured rake face. It was observed that the use of MR fluid damper reduces tool vibration and improves the cutting performance effectively. Also commercialization of this idea holds promise to the metal cutting industry.

  18. SSME Seal Test Program: Test results for sawtooth pattern damper seal

    Science.gov (United States)

    Childs, D. W.

    1986-01-01

    Direct and transverse force coefficients for 11, sawtooth-pattern, and damper-seal configurations were examined. The designation damper seal uses a deliberately roughened stator and smooth rotor to increase the net damping force developed by a seal. The designation sawtooth-pattern refers to a stator roughness pattern. The sawtooth pattern yields axial grooves in the stator which are interrupted by spacer elements which act as flow constrictions or dams. All seals use the same smooth rotor and have the same, constant, minimum clearance. The stators examined the consequences of changes in the following design parameters: (1) axial-groove depth; (2) number of teeth: (3) number of sawtooth sections; (4) number of spacer elements; (5) dam width; (6) axially aligned sawtooth sections versus axially-staggered sawtooth sections; and (7) groove geometry. It is found that none of the sawtooth-pattern seal performs as well as the best round-hole-pattern seal. Maximum damping configurations for the sawtooth and round-hole-pattern stators have comparable stiffness performance. Several of the sawtooth pattern stators outperformed the best round-hole pattern seal.

  19. Comparative performance of passive devices for piping system under seismic excitation

    Energy Technology Data Exchange (ETDEWEB)

    Kumar, Praveen, E-mail: pra_veen74@rediffmail.com [Bhabha Atomic Research Centre, Trombay, Mumbai, 400085 (India); Jangid, R.S. [Department of Civil Engineering, Indian Institute of Technology Bombay, Powai, Mumbai, 400076 (India); Reddy, G.R. [Bhabha Atomic Research Centre, Trombay, Mumbai, 400085 (India)

    2016-03-15

    Highlights: • Correlated the analytical results obtained from the proposed analytical procedures with experimental results in the case of XPD. • Substantial reduction of the seismic response of piping system with passive devices is observed. • Significant increase in the modal damping of the piping system is noted. • There exist an optimum parameters of the passive devices. • Good amount of energy dissipation is observed by using passive devices. - Abstract: Among several passive control devices, X-plate damper, viscous damper, visco-elastic damper, tuned mass damper and multiple tuned mass dampers are popular and used to mitigate the seismic response in the 3-D piping system. In the present paper detailed studies are made to see the effectiveness of the dampers when used in 3-D piping system subjected to artificial earthquake with increasing amplitudes. The analytical results obtained using Wen's model are compared with the corresponding experimental results available which indicated a good match with the proposed analytical procedure for the X-plate dampers. It is observed that there is significant reduction in the seismic response of interest like relative displacement, acceleration and the support reaction of the piping system with passive devices. In general, the passive devices under particular optimum parameters such as stiffness and damping are very effective and practically implementable for the seismic response mitigation, vibration control and seismic requalification of piping system.

  20. Digital simulation of power electronic systems

    International Nuclear Information System (INIS)

    Mehring, P.; Jentsch, W.; John, G.; Kraemer, D.

    1981-01-01

    The following paper contains the final report on the NETSIM-Project. The purpose of this project is to develop a special digital simulation system, which could serve as a base for routine application of simulation in planning and development of power electronic systems. The project is realized in two steps. First a basic network analysis system is established. With this system the basic models and methods in treating power electronic networks could be probed. The resulting system is then integrated into a general digital simulation system for continous systems (CSSL-System). This integrated simulation system allows for convenient modeling and simulation of power electronic systems. (orig.) [de

  1. Localization of equipment for digital plant protection system

    Energy Technology Data Exchange (ETDEWEB)

    Koo, I. S.; Park, H. Y.; Lee, C. K. and others

    2000-10-01

    The objective of this project lies on the development of design requirements, establishment of structure and manufacture procedures, development of the software verification and validation(V and V) techniques of the digital plant protection system. The functional requirements based on the analog protection system and digital design requirements are introduced, the processor and system bus for safety grade equipment are selected and the interface requirements and the design specification have been developed in order to manufacture the quick prototype of the digital plant protection system. The selection guidelines of parts, software development and coding and testing for digital plant protection system have been performed through manufacturing the quick prototype based on the developed design specification. For the software verification and validation, the software review plan and techniques of verification and validation have been researched. The digital validation system is developed in order to verify the quick prototype. The digital design requirements are reviewed by the software safety plan and V and V plans. The formal methods for verifying the safety-grade software are researched, then the methodology of formal analysis and testing have been developed.

  2. Localization of equipment for digital plant protection system

    International Nuclear Information System (INIS)

    Koo, I. S.; Park, H. Y.; Lee, C. K. and others

    2000-10-01

    The objective of this project lies on the development of design requirements, establishment of structure and manufacture procedures, development of the software verification and validation(V and V) techniques of the digital plant protection system. The functional requirements based on the analog protection system and digital design requirements are introduced, the processor and system bus for safety grade equipment are selected and the interface requirements and the design specification have been developed in order to manufacture the quick prototype of the digital plant protection system. The selection guidelines of parts, software development and coding and testing for digital plant protection system have been performed through manufacturing the quick prototype based on the developed design specification. For the software verification and validation, the software review plan and techniques of verification and validation have been researched. The digital validation system is developed in order to verify the quick prototype. The digital design requirements are reviewed by the software safety plan and V and V plans. The formal methods for verifying the safety-grade software are researched, then the methodology of formal analysis and testing have been developed

  3. Using block pulse functions for seismic vibration semi-active control of structures with MR dampers

    Science.gov (United States)

    Rahimi Gendeshmin, Saeed; Davarnia, Daniel

    2018-03-01

    This article applied the idea of block pulse functions in the semi-active control of structures. The BP functions give effective tools to approximate complex problems. The applied control algorithm has a major effect on the performance of the controlled system and the requirements of the control devices. In control problems, it is important to devise an accurate analytical technique with less computational cost. It is proved that the BP functions are fundamental tools in approximation problems which have been applied in disparate areas in last decades. This study focuses on the employment of BP functions in control algorithm concerning reduction the computational cost. Magneto-rheological (MR) dampers are one of the well-known semi-active tools that can be used to control the response of civil Structures during earthquake. For validation purposes, numerical simulations of a 5-story shear building frame with MR dampers are presented. The results of suggested method were compared with results obtained by controlling the frame by the optimal control method based on linear quadratic regulator theory. It can be seen from simulation results that the suggested method can be helpful in reducing seismic structural responses. Besides, this method has acceptable accuracy and is in agreement with optimal control method with less computational costs.

  4. Development and application of all-digital monitoring system

    International Nuclear Information System (INIS)

    Xu Tao; Li Jing; Wang Wei

    2014-01-01

    All digital control system has developed into a mainstream means of monitoring, and achieved information, intelligence, and networking. All-digital control system is characterized by clear image, large transport stream, so the higher the data storage and network bandwidth should be required. Existing analog surveillance system architecture, hardware and software configuration can not meet the requirements of all-digital monitoring system, so how to solve the original analog surveillance system is gradually transformed into fully digital monitoring system, to avoid incompatibility issues in surveillance monitoring system upgrade become a research project. This paper describes the advantages and future direction of megapixels camera and proposes key technologies to solve the resolution and frame rate with the actual project requirements, achieves a core technology of megapixels video surveillance system, and proposes solutions for the actual renovation project problems. (authors)

  5. Experimental Comparison of Dynamic Responses of a Tension Moored Floating Wind Turbine Platform with and without Spring Dampers

    Science.gov (United States)

    Wright, C.; O'Sullivan, K.; Murphy, J.; Pakrashi, V.

    2015-07-01

    The offshore wind industry is rapidly maturing and is now expanding to more extreme environments in deeper water and farther from shore. To date fixed foundation types (i.e. monopoles, jackets) have been primarily used but become uneconomical in water depths greater than 50m. Floating foundations have more complex dynamics but at the moment no design has reached commercialization, although a number of devices are being tested at prototype stage. The development of concepts is carried out through physical model testing of scaled devices such that to better understand the dynamics of the system and validate numerical models. This paper investigates the testing of a scale model of a tension moored wind turbine at two different scales and in the presence and absence of a spring damper controlling its dynamic response. The models were tested under combined wave and wind thrust loading conditions. The analysis compares the motions of the platform at different scales and structural conditions through RAO, testing a mooring spring damper for load reductions.

  6. Investigation of damping potential of strip damper on a real turbine blade

    NARCIS (Netherlands)

    Afzal, M.; Lopez Arteaga, I.; Kari, L.; Kharyton, V.

    2016-01-01

    This paper investigates the damping potential of strip dampers on a real turbine bladed disk. A 3D numerical friction contact model is used to compute the contact forces by means of the Alternate Frequency Time domain method. The Jacobian matrix required during the iterative solution is computed in

  7. Passivity Enhancement of Grid-Tied Converters by Series LC-Filtered Active Damper

    DEFF Research Database (Denmark)

    Bai, Haofeng; Wang, Xiongfei; Loh, Poh Chiang

    2017-01-01

    in the literature. Its effect with parasitic capacitance present in the grid has also usually been ignored, even though it may bring new challenges to the active damper. To address these issues, passivity is applied to study the grid converter stability before the understanding gained is used for formulating...

  8. General digitalized system on nuclear power plants

    International Nuclear Information System (INIS)

    Akagi, Katsumi; Kadohara, Hozumi; Taniguchi, Manabu

    2000-01-01

    Hitherto, instrumentation control system in a PWR nuclear power plant has stepwisely adopted digital technology such as application of digital instrumentation control device to ordinary use (primary/secondary system control device, and so on), application of CRT display system to monitoring function, and so forth, to realize load reduction of an operator due to expansion of operation automation range, upgrading of reliability and maintenance due to self-diagnosis function, reduction of mass in cables due to multiple transfer, and upgrading of visual recognition due to information integration. In next term PWR plant instrumentation control system, under consideration of application practice of conventional digital technology, application of general digitalisation system to adopt digitalisation of overall instrumentation control system containing safety protection system, and central instrumentation system (new type of instrumentation system) and to intend to further upgrade economics, maintenance, operability/monitoring under security of reliability/safety is planned. And, together with embodiment of construction program of the next-term plant, verification at the general digitalisation proto-system aiming at establishment of basic technology on the system is carried out. Then, here was described on abstract of the general digitalisation system and characteristics of a digital type safety protection apparatus to be adopted in the next-term plant. (G.K.)

  9. Clinical applications of SONIALVISION 100 digital diagnostic table system

    International Nuclear Information System (INIS)

    Shiomi, Takeshi; Shimizu, Tatsuya; Iinuma, Masao; Takemoto, Hajime; Tanaka, Shuji

    2003-01-01

    This report refers to the clinical applications of our newly developed SONIALVISION 100 fully digitalized X-ray diagnostic table system. The main design concept of the SONIALVISION 100 system is the improvement of workflow in various clinical fields. The development of digital imaging technologies has come to allow fully digitalized X-ray diagnostic table systems to be widely utilized in various clinical applications, including interventional radiology (IVR) and examinations using contrast medium. This report mainly refers to the clinical applications of the Shimadzu SONIALVISION 100 digitalized X-ray diagnostic table system, also presenting some typical image data demonstrating the high efficiency, made available through the use of this new system, in high-speed spot imaging and digital tomography. (author)

  10. Quantitative risk assessment of digitalized safety systems

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Sung Min; Lee, Sang Hun; Kang, Hym Gook [KAIST, Daejeon (Korea, Republic of); Lee, Seung Jun [UNIST, Ulasn (Korea, Republic of)

    2016-05-15

    A report published by the U.S. National Research Council indicates that appropriate methods for assessing reliability are key to establishing the acceptability of digital instrumentation and control (I and C) systems in safety-critical plants such as NPPs. Since the release of this issue, the methodology for the probabilistic safety assessment (PSA) of digital I and C systems has been studied. However, there is still no widely accepted method. Kang and Sung found three critical factors for safety assessment of digital systems: detection coverage of fault-tolerant techniques, software reliability quantification, and network communication risk. In reality the various factors composing digitalized I and C systems are not independent of each other but rather closely connected. Thus, from a macro point of view, a method that can integrate risk factors with different characteristics needs to be considered together with the micro approaches to address the challenges facing each factor.

  11. A Brief Discussion Regarding Types of Cavitation in Squeeze Film Dampers and Cavitation Effects

    Directory of Open Access Journals (Sweden)

    Laurentiu MORARU

    2017-03-01

    Full Text Available Squeeze film dampers (SFD are probably the most used shaft control devices in aircraft jet engines; SFDs consist in oil films, elastic elements and various antirotational devices that tune the stiffness and damping of the shafts’ supports and consequently adjust the lateral dynamics of the shaft. Fluid layers in SFDs are usually thin, hence the modeling can often be done using the Reynolds’ theory,; however, some of the main features of the film, namely the behavior of the fluid in the divergent, negative squeeze area, where discontinuities may appear in the liquid, are still subject to intense research. This paper will discuss some aspects regarding the types of cavitation that appear in squeeze film dampers and some of the effects of cavitation on the SFDs.

  12. Experimental OAI-Based Digital Library Systems

    Science.gov (United States)

    Nelson, Michael L. (Editor); Maly, Kurt (Editor); Zubair, Mohammad (Editor); Rusch-Feja, Diann (Editor)

    2002-01-01

    The objective of Open Archives Initiative (OAI) is to develop a simple, lightweight framework to facilitate the discovery of content in distributed archives (http://www.openarchives.org). The focus of the workshop held at the 5th European Conference on Research and Advanced Technology for Digital Libraries (ECDL 2001) was to bring researchers in the area of digital libraries who are building OAI based systems so as to share their experiences, problems they are facing, and approaches they are taking to address them. The workshop consisted of invited talks from well-established researchers working in building OAI based digital library system along with short paper presentations.

  13. Operation of the transverse feedback system at the CERN SPS

    International Nuclear Information System (INIS)

    Bossart, R.; Louwerse, R.; Mourier, J.; Vos, L.

    1987-01-01

    To prevent transverse instabilities at high beam intensity in the SPS, the transverse feedback system for damping the betatron oscillations has been upgraded for larger damping decrements and for increased system's bandwidth. The feedback loop now contains a digital delay line cancellor, so that the damper works with a velocity feedback Δx/Δt, unaffected by the closed orbit position x at the pick-up station. The digital processing of the feedback signal facilitates nonlinear feedback techniques such as antidamping and ''band-bang'' feedback. The ''bang-bang'' feedback provides the maximum possible damping rate of the injection oscillations in the SPS-collider, in order to minimize the emittance increase caused by filamentation. The antidamping nonlinearity provides small continuous beam oscillations of 50 μm amplitude for tracking the machine tune Q with a phase locked loop

  14. Oscilloscope trace photograph digitizing system (TRACE)

    International Nuclear Information System (INIS)

    Richards, M.; Dabbs, R.D.

    1977-10-01

    The digitizing system allows digitization of photographs or sketches of waveforms and then the computer is used to reduce and analyze the data. The software allows for alignment, calibration, removal of baselines, removal of unwanted points and addition of new points which makes for a fairly versatile system as far as data reduction and manipulation are concerned. System considerations are introduced first to orient the potential user to the process of digitizing information. The start up and actual commands for TRACE are discussed. Detailed descriptions of each subroutine and program section are also provided. Three general examples of typical photographs are included. A partial listing of FAWTEK is made available. Once suitable arrays that contain the data are arranged, ''GO FA'' (active FAWTEK) and many mathematical operations to further analyze the data may be performed

  15. Converting Constant Volume, Multizone Air Handling Systems to Energy Efficient Variable Air Volume Multizone Systems

    Science.gov (United States)

    2017-10-26

    TO OTHER ZONE DAMPERS N.O. TEMPERATURE SENSOR CHILLED WATER ZONE 1 STAT SUPPLY FAN COLD DECK COIL TO OTHER ZONE DAMPERS ZONE 1 DAMPER ACTUATOR HOT... water pump usage were considered. Figure 25. Condensing Boiler Combustion Efficiencies 3. Chilled water system losses : Similarly, electrical energy...required to meet cooling demands at the chilled water coil BTU meter is dependent on network losses and chiller energy efficiency ratios. Using

  16. Perencanaan Modifikasi Rangka Busur Baja pada Jembatan Pemali disertai Damper sebagai Longitudinal Stopper

    Directory of Open Access Journals (Sweden)

    Bintang Mahardhika

    2017-03-01

    Full Text Available Jembatan Pemali merupakan jembatan yang terletak di Kota Brebes. Jembatan ini menjadi akses penting yang menghubungkan antara Kota Semarang dan Kota Jakarta. Jembatan Pemali sering mengalami perbaikan dalam segi struktural setiap bulannya, hal ini diakibatkan oleh semakin padat volume kendaraan terutama truk dengan muatan berat. Permasalahan ini yang melatarbelakangi pembangunan Jembatan Pemali yang baru agar menunjang dalam sarana transportasi. Penelitian ini memodifikasi Jembatan Pemali menjadi sistem busur rangka baja. Jembatan didesain dengan tinggi 18 meter, bentang 100 meter dan lebar 9 meter. Penelitian ini menggunakan kombinasi pembebanan sesuai SNI T-02-2005 dan SNI 1725-2016. Dengan menggunakan progam bantu SAP2000, kombinasi KUAT 1 (SNI-1725-2016 menghasilkan output gaya yang lebih besar daripada kombinasi lainnya sehingga kombinasi tersebut digunakan untuk menentukan profil rangka atas jembatan. Analisis pengaruh damper dengan tipe Lock-Up Device menggunakan progam bantu SAP2000 dengan kombinasi beban yang menentukan dalam perencanaan damper sebagai longitudinal stopper adalah kombinasi EKSTREM I (SNI-1725-2016. Hasil dari analisis dengan progam bantu SAP2000 profil utama yang terbesar pada jembatan busur menggunakan BOX 500x500x25 serta dengan adanya damper struktur utama jembatan mampu mengurangi deformasi sebesar 16%. Dalam merencanakan bangunan bawah jembatan, dilakukan kontrol guling dan geser pada abutment jembatan serta untuk tiang pancang jembatan dilakukan kontrol berdasarkan daya dukung tanah dan tipe material yang digunakan. Dari perencanaan tersebut, didapatkan dimensi abutment 11x11x10 meter serta kebutuhan tiang pancang jembatan 36 buah. Hasil seluruh perhitungan Penelitian ini dituangkan dalam gambar teknik standar.

  17. NRC perspectives on the digital system review process

    International Nuclear Information System (INIS)

    Mauck, J.L.

    1998-01-01

    Since about 1988, the USNRC has been involved in the review of digital retrofits to instrumentation and control (I and C) systems in nuclear power plants. Initially, this involvement was limited but with the advent of the 1990s, NRC involvement has become greater because of increased interest in and application of digital systems as existing analog systems become obsolete. Criteria for the design of such systems to ensure safety has been promulgated over the years and the USNRC has been actively involved both nationally and internationally with this effort. With the publication of the Zion Eagle 21 Safety Evaluation Report in 1992, Generic Letter 95-02 in April 1995 which endorses EPRI guidance document TR-102348 on digital upgrades and the latest revision to Regulatory Guide 1.152 which endorses IEEE 7.4.3.2-1993; a basic digital system review process was established. The NRC supplemented this review process with recently issued inspection procedures for use by NRC inspectors when conducting onsite reviews of digital modifications. In addition, the NRC undertook a major effort to codify the above guidance and the experience gained from digital system reviews of both operating plant modifications and advanced reactor designs, over these years into a revision to Standard Review Plan, (SRP), NUREG-0800, Chapter 7, Instrumentation and Control. This SRP revision was published in June, 1997, and included new SRP sections, branch technical positions and six new regulatory guides endorsing IEEE standards on software quality. The NRC staff believes that a stable digital system review process is now in place. (author)

  18. Digital communication system

    International Nuclear Information System (INIS)

    Union, D.C.

    1980-01-01

    A digital communication system for communicating among two central consoles and a plurality of local controllers, e.g. in a radiation and monitoring system, provides communication between each of the consoles and all of the local controllers via dual paths. Each path is independent of the other and each extends from one of the consoles to all of the local controllers from opposite directions, thereby forming a unique non-continuous loop. (author)

  19. Advanced digital image archival system using MPEG technologies

    Science.gov (United States)

    Chang, Wo

    2009-08-01

    Digital information and records are vital to the human race regardless of the nationalities and eras in which they were produced. Digital image contents are produced at a rapid pace from cultural heritages via digitalization, scientific and experimental data via high speed imaging sensors, national defense satellite images from governments, medical and healthcare imaging records from hospitals, personal collection of photos from digital cameras. With these mass amounts of precious and irreplaceable data and knowledge, what standards technologies can be applied to preserve and yet provide an interoperable framework for accessing the data across varieties of systems and devices? This paper presents an advanced digital image archival system by applying the international standard of MPEG technologies to preserve digital image content.

  20. Fault tolerant digital control systems for boiling water reactors

    International Nuclear Information System (INIS)

    Chakraborty, S.; Cash, N.R.

    1986-01-01

    In a Boiling Water Reactor nuclear power plant, the power generation control function is divided into several systems, each system controlling only a part of the total plant. Presently, each system is controlled by conventional analog or digital logic circuits with little interaction for coordinated control. The advent of microprocessors has allowed the development of distributed fault-tolerant digital controls. The objective is to replace these conventional controls with fault-tolerant digital controls connected together with digital communication links to form a fully integrated nuclear power plant control system

  1. Modelling of magnetorheological squeeze film dampers for vibration suppression of rigid rotors

    Czech Academy of Sciences Publication Activity Database

    Zapoměl, Jaroslav; Ferfecki, Petr; Kozánek, Jan

    2017-01-01

    Roč. 127, Jul SI (2017), s. 191-197 ISSN 0020-7403 R&D Projects: GA ČR GA15-06621S Institutional support: RVO:61388998 Keywords : squeeze film damper * magnetorheological fluid * bilinear material * rigid rotor * frequency response Subject RIV: JR - Other Machinery OBOR OECD: Mechanical engineering Impact factor: 2.884, year: 2016

  2. Ageing effects due to inactivity for magnetorheological seismic dampers: a 10-year experimental investigation

    Science.gov (United States)

    Caterino, N.; Spizzuoco, M.; Occhiuzzi, A.

    2018-06-01

    The proposed work gives a response, based on the experimental evidence, to the issue of long-term magnetorheological (MR) dampers’ behavior, when they are applied for structural control of earthquake induced vibrations. MR control devices, designed for infrequent dynamic loads as earthquakes, might be dormant for most of their life until a seismic event hits the hosting controlled structure. Two prototype MR devices have been tested three times, first in 2008, then in 2013 after five years of absolute inactivity, and finally in 2017 after further four years of rest. The comparison between the results of the three experimental testing activities is made in terms of force-displacement loops, dissipated energy and maximum reacting force. It is shown that only the first stroke of the damper is characterized by an unexpected mechanical response. However, after this first movement, the damper comes back to behave similarly to what was before the rest, with only a slight not reversible decrease of the damping force. This reduction results to be more significant (about 5%) for larger currents, while less significant in the case of zero feeding current. From a civil engineering perspective, this performance decay is definitely acceptable, even if it is referred to a possible cause, deeply studied in literature, that could continue endangering the mechanical response of the devices over time. The paper shows the experimental results, but the possible causes of mechanical deterioration of the dampers will be discussed also.

  3. Connected digit speech recognition system for Malayalam language

    Indian Academy of Sciences (India)

    A connected digit speech recognition is important in many applications such as automated banking system, catalogue-dialing, automatic data entry, automated banking system, etc. This paper presents an optimum speaker-independent connected digit recognizer for Malayalam language. The system employs Perceptual ...

  4. Force effects on rotor of squeeze film damper using Newtonian and non-Newtonian fluid

    Science.gov (United States)

    Dominik, Šedivý; Petr, Ferfecki; Simona, Fialová

    2017-09-01

    This article presents the evaluation of force effects on rotor of squeeze film damper. Rotor is eccentric placed and its motion is translate-circular. The amplitude of rotor motion is smaller than its initial eccentricity. The force effects are calculated from pressure and viscous forces which were gained by using computational modeling. Two types of fluid were considered as filling of damper. First type of fluid is Newtonian (has constant viscosity) and second type is magnetorheological fluid (does not have constant viscosity). Viscosity of non-Newtonian fluid is given using Bingham rheology model. Yield stress is a function of magnetic induction which is described by many variables. The most important variables of magnetic induction are electric current and gap width which is between rotor and stator. Comparison of application two given types of fluids is shown in results.

  5. Stochastic Response of an Inclined Shallow Cable with Linear Viscous Dampers under Stochastic Excitation

    DEFF Research Database (Denmark)

    Zhou, Qiang; Nielsen, Søren R.K.; Qu, Weilian

    2010-01-01

    Considering the coupling between the in-plane and out-of-plane vibration, the stochastic response of an inclined shallow cable with linear viscous dampers subjected to Gaussian white noise excitation is investigated in this paper. Selecting the static deflection shape due to a concentrated force...... together with the C-type Gram-Charlier expansion with a fourth-order closure are applied to obtain statistical moments, power spectral density and probabilistic density function of the cable response, whose availability is verified by Monte Carlo method. Taking a typical cable as an example, the influence...... of several factors, which include excitation level and direction as well as damper size, on the dynamic response of the cable is extensively investigated. It is found that the sum of mean square in-plane and out-of-plane displacement is primarily independent of the load direction when the excitation level...

  6. All Digital IQ Servo-System for CERN Linacs

    CERN Document Server

    Rohlev, A; Garoby, R

    2003-01-01

    A new VME based system has been developed and built at CERN for the servo loops regulating the field in the linac accelerating structure. It makes use of high speed digital In-phase/Quadrature (IQ) detection, digital processing, and digital IQ modulation. The digital processing and IQ modulation is done in a single PLD. The system incorporates continually variable set points, iterative learning, feed forward as well as extensive diagnostics and other features well suited for digital implementations. Built on a single VME card, it will be first used in the energy ramping RF chain of the CERN Heavy Ion Linac (linac 3) and later for upgrading the present proton linac (linac 2). This system serves also as a prototype for the future Superconducting Proton Linac (SPL). The design principle and the experimental results are described.

  7. Data compression systems for home-use digital video recording

    NARCIS (Netherlands)

    With, de P.H.N.; Breeuwer, M.; van Grinsven, P.A.M.

    1992-01-01

    The authors focus on image data compression techniques for digital recording. Image coding for storage equipment covers a large variety of systems because the applications differ considerably in nature. Video coding systems suitable for digital TV and HDTV recording and digital electronic still

  8. Virtual spring damper method for nonholonomic robotic swarm self-organization and leader following

    Science.gov (United States)

    Wiech, Jakub; Eremeyev, Victor A.; Giorgio, Ivan

    2018-04-01

    In this paper, we demonstrate a method for self-organization and leader following of nonholonomic robotic swarm based on spring damper mesh. By self-organization of swarm robots we mean the emergence of order in a swarm as the result of interactions among the single robots. In other words the self-organization of swarm robots mimics some natural behavior of social animals like ants among others. The dynamics of two-wheel robot is derived, and a relation between virtual forces and robot control inputs is defined in order to establish stable swarm formation. Two cases of swarm control are analyzed. In the first case the swarm cohesion is achieved by virtual spring damper mesh connecting nearest neighboring robots without designated leader. In the second case we introduce a swarm leader interacting with nearest and second neighbors allowing the swarm to follow the leader. The paper ends with numeric simulation for performance evaluation of the proposed control method.

  9. Modeling of digital communication systems using SIMULINK

    CERN Document Server

    Giordano, Arthur A

    2015-01-01

    Arthur Giordano, PhD, is a consultant in the field of military and commercial communications specializing in wireless communications. He is a co-founder of G5 Scientific, LLC, is a senior member of the IEEE and has taught graduate communications courses. He has developed numerous models using MathWorks®' SIMULINK®® to characterize digital communications systems. Allen Levesque, PhD, is a consultant specializing in digital communications systems, and is a partner in G5 Scientific, LLC. He has taught graduate courses in digital communications at Worcester Polytechnic Institute and is currently

  10. Digital Watermark Tracking using Intelligent Multi-Agents System

    Directory of Open Access Journals (Sweden)

    Nagaraj V. DHARWADKAR

    2010-01-01

    Full Text Available E-commerce has become a huge business and adriving factor in the development of the Internet. Onlineshopping services are well established. Due to the evolution of2G and 3G mobile networks, soon online shopping services arecomplemented by their wireless counterparts. Furthermore, inthe recent years online delivery of digital media, such as MP3audio or video or image is very popular and will become anincreasingly important part of E-commerce. The advantage ofinternet is sharing the valuable digital data which lead to misuseof digital data. To resolve the problem of misuse of digital dataon Internet we need to have strong Digital rights monitoringsystem. Digital Rights Management (DRM is fairly youngdiscipline, while some of its underlying technologies have beenknown from many years. The use of DRM for managing andprotecting intellectual property rights is a comparatively newfield. In this paper we propose a model for online digital imagelibrary copyright protection based on watermark trackingSystem.In our proposed model the tracking of watermarks onremote host nodes is done using active mobile agents. The multiagentsystem architecture is used in watermark tracking whichsupports the coordination of several component tasks acrossdistributed and flexible networks of information sources.Whereas a centralized system is susceptible to system-widefailures and processing bottlenecks, multi-agent systems aremore reliable, especially given the likelihood of individualcomponent failures.

  11. Active Tuned Mass Dampers for Control of In-Plane Vibrations of Wind Turbine Blades

    DEFF Research Database (Denmark)

    Fitzgerald, B.; Basu, Biswajit; Nielsen, Søren R.K.

    2013-01-01

    matrices. The aim of this paper is to determine whether ATMDs could be used to reduce in-plane blade vibrations in wind turbines with better performance than compared with their passive counterparts. A Euler–Lagrangian wind turbine mathematical model based on energy formulation was developed......, centrifugal, and turbulent aerodynamic loadings. Investigations show promising results for the use of ATMDs in the vibration control of wind turbine blades.......This paper investigates the use of active tuned mass dampers (ATMDs) for the mitigation of in-plane vibrations in rotating wind turbine blades. The rotating wind turbine blades with tower interaction represent time-varying dynamical systems with periodically varying mass, stiffness, and damping...

  12. A new digital land mobile satellite system

    Science.gov (United States)

    Schneider, Philip

    A description is given of the different digital services planned to be carried over existing and planned mobile satellite systems. These systems are then compared with analog services in terms of bandwidth and power efficiency. This comparison provides the rationale for the establishment of a digital land mobile satellite service (DLMSS) to use frequencies that are currently available but not yet assigned to a domestic mobile satellite system in the United States. The focus here is on the expected advantages of digital transmission techniques in accommodating additional mobile satellite systems in this portion of the spectrum, and how such techniques can fully satisfy voice, data and facsimile mobile communications requirements in a cost effective manner. A description is given of the system architecture of the DMLSS service proposed by the Geostar Messaging Corporation (GMC) and the market potential of DLMSS.

  13. Technical self reliance of digital safety systems

    Energy Technology Data Exchange (ETDEWEB)

    Kwon, Kee Choon; Lee, Dong Young [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Kim, Kook Hun [Doosan Heavy Industries and Construction, Changwon (Korea, Republic of); Choi, Seung Gap [POSCON, Pohang (Korea, Republic of)

    2009-04-15

    This paper summarizes the development results of the Korea Nuclear Instrumentation and Control System (KNICS) project sponsored by the Korean government. In this project, Man Machine Interface System (MMIS) architecture, two digital platforms, and several control systems are developed. One platform is a programmable Logic Controller (PLC) for a safety system and another platform is a Distributed Control System (DCS) for a non safety system. With the POSAFE Q PLC, a Reactor Protection System (RPS) and an Engineered Safety Feature Component Control System (ESF CCS) are developed. A Power Control System (PCS) is developed based on the DCS. The safety grade platform and the digital safety systems obtained approval for the Topical Report from the Korean regulatory body in February of 2009. Also a Korean utility and a vendor company determined KNICS results to apply them to the planned Nuclear Power Plant (NPP) in March 2009. This paper introduces the technical self reliance experiences of the safety grade platform and the digital safety systems developed in the KNICS R and D project.

  14. Digital Voting Systems and Communication in Classroom Lectures

    DEFF Research Database (Denmark)

    Mathiasen, Helle

    2015-01-01

    Studies on the use of digital voting systems in large group teaching situations have often focused on the ”non-anonymity” and control and testing functions that the technology provides. There has also been some interest in how students might use their votes tactically to gain “credits”. By focusing...... on an empirical study of students’ experiences with digital voting systems in lectures at two Danish universities, this study considers the premises and the contexts surrounding this technology. It will also aim to show that for both instructors and students, digital voting systems are a much broader resource...... than simply a device for facilitating ”non-anonymity”, test, control and allocation of credits. The case studies showed, for instance, that digital voting systems can be conducive to a more open approach in which the systems are used as communication tools and teaching resources in situations where...

  15. Immunizing digital systems against electromagnetic interference

    International Nuclear Information System (INIS)

    Ewing, P.D.; Korsah, K.; Antonescu, C.

    1993-01-01

    This paper discusses the development of the technical basis for acceptance criteria applicable to the immunization of digital systems against electromagnetic interference (EMI). The work is sponsored by the US Nuclear Regulatory Commission and stems from the safety-related issues that need to be addressed as a result of the application of digital instrumentation and control systems in nuclear power plants. Designers of digital circuits are incorporating increasingly higher clock frequencies and lower logic level voltages, thereby leading to potentially greater susceptibility of spurious interference being misinterpreted as legitimate logic. Development of the technical basis for acceptance criteria to apply to these digital systems centers around establishing good engineering practices to ensure that sufficient levels of electromagnetic compatibility (EMC) are maintained between the nuclear power plant's electronic and electromechanical systems. First, good EMC design and installation practices are needed to control the emissions from interference sources and thereby their impact on other nearby circuits and systems. Second, a test and evaluation program is needed to outline the EMI tests to be performed, the associated test methods to be followed, and adequate test limits to ensure that the circuit or system under test meets the recommended guidelines. Test and evaluation should be followed by periodic maintenance to assess whether the recommended EMI control practices continue to be adhered to as part of the routine operation of the nuclear power plant. By following these steps, the probability of encountering safety-related instrumentation problems associated with EMI will be greatly reduced

  16. Immunizing digital systems against electromagnetic interference

    International Nuclear Information System (INIS)

    Ewing, P.D.; Korsah, K.; Antonescu, C.

    1993-01-01

    This paper discusses the development of the technical basis for acceptance criteria applicable to the immunization of digital systems against electromagnetic interference (EMI). The work is sponsored by the US Nuclear Regulatory Commission and stems from the safety-related issues that need to be addressed as a result of the application of digital instrumentation and control systems in nuclear power plants. Designers of digital circuits are incorporating increasingly higher clock frequencies and lower logic level voltages, thereby leading to potentially greater susceptibility of spurious interference being misinterpreted as legitimate logic. Development of the technical basis for acceptance criteria to apply to these digital systems centers around establishing good engineering practices to ensure that sufficient levels of electromagnetic compatibility (EMC) are maintained between the nuclear power plant's electronic and electromechanical systems. First, good EMC design and installation practices are needed to control the emissions from interference sources and thereby their impact on other nearby circuits and systems. Secondly, a test and evaluation program is needed to outline the EMI tests to be performed, the associated test methods to be followed, and adequate test limits to ensure that the circuit or system under test meets the recommended guidelines. Test and evaluation should be followed by periodic maintenance to assess whether the recommended EMI control practices continue to be adhered to as part of the routine operation of the nuclear power plant. By following these steps, the probability of encountering safety-related instrumentation problems associated with EMI will be greatly reduced

  17. Synchronisation Strategy in Complex Digital Voter-based Systems

    Directory of Open Access Journals (Sweden)

    SZÁSZ Csaba

    2017-10-01

    Full Text Available Researchers in microelectronics generally agree that reliability and computing power are the two most important factors for next generation digital systems. Redundancy techniques are implemented widely to increase the reliability and fault tolerance of these systems. In this paper a triple modular redundancy (TMR majority voter based fault-tolerant digital system architecture is presented and analyzed. The vast majority of researchers that design and implement such systems usually assume that in these configurations the voter operates perfectly while is not true. This presentation outlines a specific situation when under same conditions the digital voter is exposed to misleading operation generating wrong information on its output. To overcome such situations there a versatile method has been proposed and implemented that is well suited to overcome the improper operation of TMR structures. The experimental results prove the theoretical assumptions and validate the initial expectations regarding the considered digital system fault-tolerant operation.

  18. Digital stethoscope system: the feasibility of cardiac auscultation

    Science.gov (United States)

    Pariaszewska, Katarzyna; Młyńczak, Marcel; Niewiadomski, Wiktor; Cybulski, Gerard

    2013-10-01

    The application of the digital stethoscope system is a new tendency in methods of cardiac auscultation. Heart sounds, generated by the fluctuations of blood velocity and vibrations of muscle structure, are an important signal in the primary diagnosis of heart diseases. Since the XIXs century for physical examination an analog stethoscope was used, but the development of microelectronics enable the construction of digital stethoscopes which started modern phonocardiography. The typical hardware of the system could be divided into analog and digital parts, respectively. The first one consists of microphone and pre-amplifier. The second one contains a microcontroller with peripherals for data saving and transmission. Usually the specialized software is applied for the signal acquisition and digital signal processing (filtering, spectral analysis and others). This paper presents an overview of methods used in cardiac auscultation and expected developing path in the future. It also contains the description of our digital stethoscope system, which is planned to be used in poliphysiographical studies.

  19. Using the digital reactor control systems at NPP

    International Nuclear Information System (INIS)

    Schirl, G.; Hertel, J.

    2006-01-01

    A conception of application of the digital reactor control systems (RCS) at NPP is presented. The digital RCS architecture and safety ensuring are considered. The strategy and algorithm of the operating NPP equipping with the new digital RCS are given too [ru

  20. Reliability Analysis Study of Digital Reactor Protection System in Nuclear Power Plant

    International Nuclear Information System (INIS)

    Guo, Xiao Ming; Liu, Tao; Tong, Jie Juan; Zhao, Jun

    2011-01-01

    The Digital I and C systems are believed to improve a plants safety and reliability generally. The reliability analysis of digital I and C system has become one research hotspot. Traditional fault tree method is one of means to quantify the digital I and C system reliability. Review of advanced nuclear power plant AP1000 digital protection system evaluation makes clear both the fault tree application and analysis process to the digital system reliability. One typical digital protection system special for advanced reactor has been developed, which reliability evaluation is necessary for design demonstration. The typical digital protection system construction is introduced in the paper, and the process of FMEA and fault tree application to the digital protection system reliability evaluation are described. Reliability data and bypass logic modeling are two points giving special attention in the paper. Because the factors about time sequence and feedback not exist in reactor protection system obviously, the dynamic feature of digital system is not discussed

  1. Reliability assessment of embedded digital system using multi-state function

    International Nuclear Information System (INIS)

    Choi, Jong Gyun; Seong, Poong Hyun

    2006-01-01

    This work describes a combinatorial model for estimating the reliability of the embedded digital system by means of multi-state function. This model includes a coverage model for fault-handling techniques implemented in digital systems. The fault-handling techniques make it difficult for many types of components in digital system to be treated as binary state, good or bad. The multi-state function provides a complete analysis of multi-state systems as which the digital systems can be regarded. Through adaptation of software operational profile flow to multi-state function, the HW/SW interaction is also considered for estimation of the reliability of digital system. Using this model, we evaluate the reliability of one board controller in a digital system, Interposing Logic System (ILS), which is installed in YGN nuclear power units 3 and 4. Since the proposed model is a generalized combinatorial model, the simplification of this model becomes the conventional model that treats the system as binary state. This modeling method is particularly attractive for embedded systems in which small sized application software is implemented since it will require very laborious work for this method to be applied to systems with large software

  2. Intermediate Frequency Digital Receiver Based on Multi-FPGA System

    Directory of Open Access Journals (Sweden)

    Chengchang Zhang

    2016-01-01

    Full Text Available Aiming at high-cost, large-size, and inflexibility problems of traditional analog intermediate frequency receiver in the aerospace telemetry, tracking, and command (TTC system, we have proposed a new intermediate frequency (IF digital receiver based on Multi-FPGA system in this paper. Digital beam forming (DBF is realized by coordinated rotation digital computer (CORDIC algorithm. An experimental prototype has been developed on a compact Multi-FPGA system with three FPGAs to receive 16 channels of IF digital signals. Our experimental results show that our proposed scheme is able to provide a great convenience for the design of IF digital receiver, which offers a valuable reference for real-time, low power, high density, and small size receiver design.

  3. Safety Review related to Commercial Grade Digital Equipment in Safety System

    International Nuclear Information System (INIS)

    Yu, Yeongjin; Park, Hyunshin; Yu, Yeongjin; Lee, Jaeheung

    2013-01-01

    The upgrades or replacement of I and C systems on safety system typically involve digital equipment developed in accordance with non-nuclear standards. However, the use of commercial grade digital equipment could include the vulnerability for software common-mode failure, electromagnetic interference and unanticipated problems. Although guidelines and standards for dedication methods of commercial grade digital equipment are provided, there are some difficulties to apply the methods to commercial grade digital equipment for safety system. This paper focuses on regulatory guidelines and relevant documents for commercial grade digital equipment and presents safety review experiences related to commercial grade digital equipment in safety system. This paper focuses on KINS regulatory guides and relevant documents for dedication of commercial grade digital equipment and presents safety review experiences related to commercial grade digital equipment in safety system. Dedication including critical characteristics is required to use the commercial grade digital equipment on safety system in accordance with KEPIC ENB 6370 and EPRI TR-106439. The dedication process should be controlled in a configuration management process. Appropriate methods, criteria and evaluation result should be provided to verify acceptability of the commercial digital equipment used for safety function

  4. Field-Deployable Acoustic Digital Systems for Noise Measurement

    Science.gov (United States)

    Shams, Qamar A.; Wright, Kenneth D.; Lunsford, Charles B.; Smith, Charlie D.

    2000-01-01

    Langley Research Center (LaRC) has for years been a leader in field acoustic array measurement technique. Two field-deployable digital measurement systems have been developed to support acoustic research programs at LaRC. For several years, LaRC has used the Digital Acoustic Measurement System (DAMS) for measuring the acoustic noise levels from rotorcraft and tiltrotor aircraft. Recently, a second system called Remote Acquisition and Storage System (RASS) was developed and deployed for the first time in the field along with DAMS system for the Community Noise Flight Test using the NASA LaRC-757 aircraft during April, 2000. The test was performed at Airborne Airport in Wilmington, OH to validate predicted noise reduction benefits from alternative operational procedures. The test matrix was composed of various combinations of altitude, cutback power, and aircraft weight. The DAMS digitizes the acoustic inputs at the microphone site and can be located up to 2000 feet from the van which houses the acquisition, storage and analysis equipment. Digitized data from up to 10 microphones is recorded on a Jaz disk and is analyzed post-test by microcomputer system. The RASS digitizes and stores acoustic inputs at the microphone site that can be located up to three miles from the base station and can compose a 3 mile by 3 mile array of microphones. 16-bit digitized data from the microphones is stored on removable Jaz disk and is transferred through a high speed array to a very large high speed permanent storage device. Up to 30 microphones can be utilized in the array. System control and monitoring is accomplished via Radio Frequency (RF) link. This paper will present a detailed description of both systems, along with acoustic data analysis from both systems.

  5. Dampers, fluidics and the failsafe fallacy [fire protection

    International Nuclear Information System (INIS)

    Dann, M.; Hodgson, T.

    1989-01-01

    The fire protection practices adopted at nuclear power stations generally follow the well established principles used throughout industry. Unfortunately, there is one particular area - the interaction with heating, ventilation and air conditioning (HVAC) services - where nuclear power stations pose a seemingly insoluble conflict: that between the need to contain and the need to ventilate. Now, however, solid state fire dampers using power fluidics may promise a solution. One of the key characteristics of a fluidic device is that it is 'solid state', i.e. it has no moving parts. Because of this, its inherent reliability is orders of magnitude greater than a mechanical device. (U.K.)

  6. A radiographic image archive system on digital optical disks

    International Nuclear Information System (INIS)

    Mankovich, N.J.; Taira, R.K.; Cho, P.S.; Wong, W.K.; Stewart, B.K.; Huang, H.K.

    1986-01-01

    The recent introduction of projection computed radiography (CR) systems allows radiology departments to consider digital operation in over 90% of performed procedures. Ideally, current patient procedures from CT, CT, and MR along with laser-digitized historical films should be centrally stored at their full digital resolution. Magnetic disks, because of their limited storage capacity and expense, can only retain these data on a limited basis. The author devised an optical disk archive system which automatically stores images directly onto 2.6-gigabyte optical cartridges without recourse to film. This system is in full clinical operation in the UCLA Pediatric Radiology Section of the authors' department. From this experience they present (a) an analysis of the digital archiving requirements of the Pediatric Radiology Section based on CR, CT, MR, and laser digitized films; (b) the archive and retrieval methods along with performance statistics; and (c) the procedure for assuring digital image integrity

  7. A digital control and monitoring system for PWR waste-disposal systems

    International Nuclear Information System (INIS)

    Ueda, Toshiharu; Fuchigami, Kazuyuki; Shimozato, Masao; Takazawa, Kazuo

    1982-01-01

    Mitsubishi Electric has developed a digital control and monitoring system for PWR waste-disposal systems. This novel system has improved operability due to its automated operations and control, and integrated supervisory functions. The system includes other features to improve operability: sequence control by a control computer, direct-digital process control, integrated supervision of operation states by a supervisory computer and a high-speed dataway, and CRT interfacing between the computer and dataway. (author)

  8. Rotary MR Damper for Launch/Landing Load Isolation and Resistive Crew Exercise for Exploration Spaceflight Missions

    Data.gov (United States)

    National Aeronautics and Space Administration — Develop a rotary MR (magneto rheologic) Damper to integrate into exploration spacecraft crew seats to be used as an exercise device and launch/landing load isolation...

  9. [Analog gamma camera digitalization computer system].

    Science.gov (United States)

    Rojas, G M; Quintana, J C; Jer, J; Astudillo, S; Arenas, L; Araya, H

    2004-01-01

    Digitalization of analogue gamma cameras systems, using special acquisition boards in microcomputers and appropriate software for acquisition and processing of nuclear medicine images is described in detail. Microcomputer integrated systems interconnected by means of a Local Area Network (LAN) and connected to several gamma cameras have been implemented using specialized acquisition boards. The PIP software (Portable Image Processing) was installed on each microcomputer to acquire and preprocess the nuclear medicine images. A specialized image processing software has been designed and developed for these purposes. This software allows processing of each nuclear medicine exam, in a semiautomatic procedure, and recording of the results on radiological films. . A stable, flexible and inexpensive system which makes it possible to digitize, visualize, process, and print nuclear medicine images obtained from analogue gamma cameras was implemented in the Nuclear Medicine Division. Such a system yields higher quality images than those obtained with analogue cameras while keeping operating costs considerably lower (filming: 24.6%, fixing 48.2% and developing 26%.) Analogue gamma camera systems can be digitalized economically. This system makes it possible to obtain optimal clinical quality nuclear medicine images, to increase the acquisition and processing efficiency, and to reduce the steps involved in each exam.

  10. Noise analysis of a digital radiography system

    International Nuclear Information System (INIS)

    Arnold, B.A.; Scheibe, P.O.

    1984-01-01

    The sources of noise in a digital video subtraction angiography system were identified and analyzed. Signal-to-noise ratios of digital radiography systems were measured using the digital image data recorded in the computer. The major sources of noise include quantum noise, TV camera electronic noise, quantization noise from the analog-to-digital converter, time jitter, structure noise in the image intensifier, and video recorder electronic noise. A new noise source was identified, which results from the interplay of fixed pattern noise and the lack of image registration. This type of noise may result from image-intensifier structure noise in combination with TV camera time jitter or recorder time jitter. A similar noise source is generated from the interplay of patient absorption inhomogeneities and patient motion or image re-registration. Signal-to-noise ratios were measured for a variety of experimental conditions using subtracted digital images. Image-intensifier structure noise was shown to be a dominant noise source in unsubtracted images at medium to high radiation exposure levels. A total-system signal-to-noise ratio (SNR) of 750:1 was measured for an input exposure of 1 mR/frame at the image intensifier input. The effect of scattered radiation on subtracted image SNR was found to be greater than previously reported. The detail SNR was found to vary approximately as one plus the scatter degradation factor. Quantization error noise with 8-bit image processors (signal-to-noise ratio of 890:1) was shown to be of increased importance after recent improvements in TV cameras. The results of the analysis are useful both in the design of future digital radiography systems and the selection of optimum clinical techniques

  11. Eddy damping effect of additional conductors in superconducting levitation systems

    Energy Technology Data Exchange (ETDEWEB)

    Jiang, Zhao-Fei; Gou, Xiao-Fan, E-mail: xfgou@hhu.edu.cn

    2015-12-15

    Highlights: • In this article, for the eddy current damper attached to the HTSC, we • quantitatively investigated the damping coefficient c, damping ratio, Joule heating of the copper damper, and the vibration frequency of the PM as well. • presented four different arrangements of the copper damper, and comparatively studied their damping effects and Joule heating, and finally proposed the most advisable arrangement. - Abstract: Passive superconducting levitation systems consisting of a high temperature superconductor (HTSC) and a permanent magnet (PM) have demonstrated several fascinating applications such as the maglev system, flywheel energy storage. Generally, for the HTSC–PM levitation system, the HTSC with higher critical current density J{sub c} can obtain larger magnetic force to make the PM levitate over the HTSC (or suspended below the HTSC), however, the process of the vibration of the levitated PM, provides very limited inherent damping (essentially hysteresis). To improve the dynamic stability of the levitated PM, eddy damping of additional conductors can be considered as the most simple and effective approach. In this article, for the HTSC–PM levitation system with an additional copper damper attached to the HTSC, we numerically and comprehensively investigated the damping coefficient c, damping ratio, Joule heating of the copper damper, and the vibration frequency of the PM as well. Furthermore, we comparatively studied four different arrangements of the copper damper, on the comprehensive analyzed the damping effect, efficiency (defined by c/V{sub Cu}, in which V{sub Cu} is the volume of the damper) and Joule heating, and finally presented the most advisable arrangement.

  12. The influence of the current intensity on the damping characteristics for a magneto-rheological damper of passenger car

    Science.gov (United States)

    Dobre, A.; Andreescu, C. N.; Stan, C.

    2016-08-01

    Due to their simplicity and controllability, adaptive dampers became very popular in automotive engineering industry, especially in the passenger cars industry, in spite of technological obstacles inherent and the high cost of the magnetic fluid. “MagneRide” is the first technology which uses smart fluids in the shock absorbers of the vehicles adaptive suspensions. Since the discovery of the magneto-rheological effect there is a consistent progress regarding the control algorithms and hardware part itself. These magneto-rheological devices have a major potential which can be explored in various fields of applications. At present many companies make researches for the improvement of the response time and for obtaining a better response at low frequency and amplitude of the body car oscillations. The main objective of this paper is to determine the damping characteristic of a magnetorheological shock absorber of a passenger car. The authors aim to observe how to modify the damping characteristic by changing the intensity of the electric current. The experimental researches have being carried out on a complex and modern test bench especially built for testing shock absorbers, in order to compare the damping characteristic of the classical damper with the magneto-rheological damper.

  13. Discrete-time sliding mode control for MR vehicle suspension system

    Energy Technology Data Exchange (ETDEWEB)

    Sohn, J W; Choi, S B [Smart Structures and Systems Laboratory, Department of Mechanical Engineering, Inha University, Incheon 402-751 (Korea, Republic of); Wereley, N M [Smart Structures Laboratory, Department of Aerospace Engineering, University of Maryland, College Park, MD 20742 (United States)], E-mail: seungbok@inha.ac.kr

    2009-02-01

    This paper presents control performance of a full-vehicle suspension system featuring magnetorheological (MR) dampers via a discrete-time sliding mode control algorithm (DSMC). A cylindrical MR damper is designed by incorporating Bingham model of the MR fluid and the field-dependent damping characteristics of the MR damper are evaluated. A full-vehicle suspension model installed with independent four MR dampers is constructed and the governing equations which include vertical, pitch and roll motion are derived. A discrete-time control model is established with considering system uncertainties and a discrete-time sliding mode controller which has inherent robustness to model uncertainty and external disturbance is formulated. Vibration control performances under bump excitation are evaluated and presented.

  14. Discrete-time sliding mode control for MR vehicle suspension system

    International Nuclear Information System (INIS)

    Sohn, J W; Choi, S B; Wereley, N M

    2009-01-01

    This paper presents control performance of a full-vehicle suspension system featuring magnetorheological (MR) dampers via a discrete-time sliding mode control algorithm (DSMC). A cylindrical MR damper is designed by incorporating Bingham model of the MR fluid and the field-dependent damping characteristics of the MR damper are evaluated. A full-vehicle suspension model installed with independent four MR dampers is constructed and the governing equations which include vertical, pitch and roll motion are derived. A discrete-time control model is established with considering system uncertainties and a discrete-time sliding mode controller which has inherent robustness to model uncertainty and external disturbance is formulated. Vibration control performances under bump excitation are evaluated and presented.

  15. Tuned liquid column dampers for mitigation of edgewise vibrations in rotating wind turbine blades

    DEFF Research Database (Denmark)

    Zhang, Zili; Basu, Biswajit; Nielsen, Søren R.K.

    2015-01-01

    are the mounting position, the mass ratio, the geometries, and the head loss coefficient of the damper. Based on a reduced 2-DOF nonlinear model developed by the authors, the optimization of these parameters are carried out by minimizing the standard deviation of the edgewise tip displacement...

  16. Experimental Research on an Active Sting Damper in a Low Speed Acoustic Wind Tunnel

    Directory of Open Access Journals (Sweden)

    Jinjin Chen

    2014-01-01

    Full Text Available Wind tunnels usually use long cantilever stings to support aerodynamic models in order to reduce support system flow interference on experimental data. However, such support systems are a potential source of vibration problems which limit the test envelope and affect data quality due to the inherently low structural damping of the systems. When exposed to tunnel flow, turbulence and model flow separation excite resonant Eigenmodes of a sting structure causing large vibrations due to low damping. This paper details the development and experimental evaluation of an active damping system using piezoelectric devices with balance signal feedback both in a lab and a low speed acoustic wind tunnel and presents the control algorithm verification tests with a simple cantilever beam. It is shown that the active damper, controlled separately by both PID and BP neural network, has effectively attenuated the vibration. For sting mode only, 95% reduction of displacement response under exciter stimulation and 98% energy elimination of sting mode frequency have been achieved.

  17. Adoption of digital safety protection system in Japan

    International Nuclear Information System (INIS)

    Ogiso, Z.

    1998-01-01

    The application of micro-processor-based digital controllers has been widely propagated among various industries in recent years. While in the nuclear power plant industry, the application of them has also been expanding gradually starting from non-safety related systems, taking advantage of their reliability and maintainability over the conventional analog devices. Based on the careful study of the feasibility of digital controllers to the safety protection system, the Tokyo Electric Power Company proposed on May 1989 the adoption of digital controllers to the safety protection system in the Application for Permission of Establishment of Kashiwazaki-Kariwa units 6 and 7 (ABWR-1350Mwe each). MITI, Ministry of International Trade and Industry, the Japanese regulatory body for electric power generating facilities, had approved this application after careful review. This paper describes a series of supporting activities leading to the MITI's approval of the digital safety protection system and the MITI's licensing activities. (author)

  18. Coupled-Mode Flutter of Wind Turbines and its Suppression Using Torsional Viscous Damper

    DEFF Research Database (Denmark)

    Zhang, Zili; Chen, Bei; Nielsen, Søren R. K.

    2017-01-01

    The trend towards lighter and more flexible blades may lead to aeroelastic instability of wind turbines under certain circumstances, resulting in rapid destructive failure or limit-cycle oscillations of the structural components. For pitch-regulated wind turbines, classical flutter is believed...... between blade vibrations with tower and drivetrain motions are also considered, making this model capable for coupled-mode flutter analysis of a complete wind turbine system. The parameters of the model have been calibrated to the DTU 10MW wind turbine, and the critical flutter speed of the rotor is shown...... to be about 1.6 times its nominal rotational speed. A novel torsional viscous damper is then proposed to suppress torsional blade vibration and to enhance flutter stability of wind turbines....

  19. Development of Final Running Test System for Digital Systems

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Kwang-Dae; Lee, Eui-Jong; Lim, Hee-Taek; Kim, Min-Seok [KHNP Central Research Institute, Daejeon (Korea, Republic of)

    2016-10-15

    In nuclear industry, the newly designed systems to upgrade are qualified to meet IEEE standards and the regulatory guidelines for their functions, performance and reliability requirements. Failure Mode and Effect Analysis, Fault Tree Analysis, and Hazard Analysis have been used to improve the reliability of the control system. To ensure the completeness of the software, the verification and validation processes are carried out during the development process. In spite of the many efforts depending on the analysis and procedures, there are limitations to improve the reliability. The lessons learned from the currently installed system failures show the incompleteness of the final integration test. The current point-to-point and logic-to-logic separate test procedures manually performed by the engineers can cause some procedures missed and have effects on the critical functions. The design processes of the digital systems are met in accordance with the international standards and regulatory guidelines. The lessons learned from the failures of the running digital systems showed the limitations of the current verification and validation efforts. The various improvements and attempts have been considered including the expert review processes and the completeness of the test. In this paper, the Final Running Test Method evaluating the completeness of the digital system using the control patterns and the Test System Architecture are proposed.

  20. Development of Final Running Test System for Digital Systems

    International Nuclear Information System (INIS)

    Lee, Kwang-Dae; Lee, Eui-Jong; Lim, Hee-Taek; Kim, Min-Seok

    2016-01-01

    In nuclear industry, the newly designed systems to upgrade are qualified to meet IEEE standards and the regulatory guidelines for their functions, performance and reliability requirements. Failure Mode and Effect Analysis, Fault Tree Analysis, and Hazard Analysis have been used to improve the reliability of the control system. To ensure the completeness of the software, the verification and validation processes are carried out during the development process. In spite of the many efforts depending on the analysis and procedures, there are limitations to improve the reliability. The lessons learned from the currently installed system failures show the incompleteness of the final integration test. The current point-to-point and logic-to-logic separate test procedures manually performed by the engineers can cause some procedures missed and have effects on the critical functions. The design processes of the digital systems are met in accordance with the international standards and regulatory guidelines. The lessons learned from the failures of the running digital systems showed the limitations of the current verification and validation efforts. The various improvements and attempts have been considered including the expert review processes and the completeness of the test. In this paper, the Final Running Test Method evaluating the completeness of the digital system using the control patterns and the Test System Architecture are proposed

  1. Development of FPGA-based digital signal processing system for radiation spectroscopy

    International Nuclear Information System (INIS)

    Lee, Pil Soo; Lee, Chun Sik; Lee, Ju Hahn

    2013-01-01

    We have developed an FPGA-based digital signal processing system that performs both online digital signal filtering and pulse-shape analysis for both particle and gamma-ray spectroscopy. Such functionalities were made possible by a state-of-the-art programmable logic device and system architectures employed. The system performance as measured, for example, in the system dead time and accuracy for pulse-height and rise-time determination, was evaluated with standard alpha- and gamma-ray sources using a CsI(Tl) scintillation detector. It is resulted that the present system has shown its potential application to various radiation-related fields such as particle identification, radiography, and radiation imaging. - Highlights: ► An FPGA-based digital processing system was developed for radiation spectroscopy. ► Our digital system has a 14-bit resolution and a 100-MHz sampling rate. ► The FPGA implements the online digital filtering and pulse-shape analysis. ► The pileup rejection is implemented in trigger logic before digital filtering process. ► Our digital system was verified in alpha-gamma measurements using a CsI detector

  2. Unattended digital video surveillance: A system prototype for EURATOM safeguards

    International Nuclear Information System (INIS)

    Chare, P.; Goerten, J.; Wagner, H.; Rodriguez, C.; Brown, J.E.

    1994-01-01

    Ever increasing capabilities in video and computer technology have changed the face of video surveillance. From yesterday's film and analog video tape-based systems, we now emerge into the digital era with surveillance systems capable of digital image processing, image analysis, decision control logic, and random data access features -- all of which provide greater versatility with the potential for increased effectiveness in video surveillance. Digital systems also offer other advantages such as the ability to ''compress'' data, providing increased storage capacities and the potential for allowing longer surveillance Periods. Remote surveillance and system to system communications are also a benefit that can be derived from digital surveillance systems. All of these features are extremely important in today's climate Of increasing safeguards activity and decreasing budgets -- Los Alamos National Laboratory's Safeguards Systems Group and the EURATOM Safeguards Directorate have teamed to design and implement a period surveillance system that will take advantage of the versatility of digital video for facility surveillance system that will take advantage of the versatility of digital video for facility surveillance and data review. In this Paper we will familiarize you with system components and features and report on progress in developmental areas such as image compression and region of interest processing

  3. Photogrammetry, Digital mapping and Land Informations Systems

    DEFF Research Database (Denmark)

    Frederiksen, Poul

    1998-01-01

    Monitoring activities on photogrammetry, digital mapping and land information systems in State Land Service in Latvia in relation to the EU Phare Project Phase II, Technical Assistance to land Privatisation and registration in Latvia.......Monitoring activities on photogrammetry, digital mapping and land information systems in State Land Service in Latvia in relation to the EU Phare Project Phase II, Technical Assistance to land Privatisation and registration in Latvia....

  4. Passivity-based design of robust passive damping for LCL-filtered voltage source converters

    DEFF Research Database (Denmark)

    Wang, Xiongfei; Blaabjerg, Frede; Loh, Poh Chiang

    2015-01-01

    Passive damping is proven as a robust stabilizing technique for LCL-filtered voltage source converters. However, conventional design methods of passive dampers are based on the passive components only, while the inherent damping effect of time delay in the digital control system is overlooked....... In this paper, a frequency-domain passivity-based design approach is proposed, where the passive dampers are designed to eliminate the negative real part of the converter output admittance with closed-loop current control, rather than shaping the LCL-filter itself. Thus, the influence of time delay...... in the current control is included, which allows a relaxed design of the passive damper with the reduced power loss and improved stability robustness against grid parameters variations. Design procedures of two commonly used passive dampers with LCL-filtered VSCs are illustrated. Experimental results validate...

  5. Simulation Study on Train-Induced Vibration Control of a Long-Span Steel Truss Girder Bridge by Tuned Mass Dampers

    Directory of Open Access Journals (Sweden)

    Hao Wang

    2014-01-01

    Full Text Available Train-induced vibration of steel truss bridges is one of the key issues in bridge engineering. This paper talks about the application of tuned mass damper (TMD on the vibration control of a steel truss bridge subjected to dynamic train loads. The Nanjing Yangtze River Bridge (NYRB is taken as the research object and a recorded typical train load is included in this study. With dynamic finite element (FE method, the real-time dynamic responses of NYRB are analyzed based on a simplified train-bridge time-varying system. Thereinto, two cases including single train moving at one side and two trains moving oppositely are specifically investigated. According to the dynamic characteristics and dynamic responses of NYRB, the fourth vertical bending mode is selected as the control target and the parameter sensitivity analysis on vibration control efficiency with TMD is conducted. Using the first-order optimization method, the optimal parameters of TMD are then acquired with the control efficiency of TMD, the static displacement of Midspan, expenditure of TMDs, and manufacture difficulty of the damper considered. Results obtained in this study can provide references for the vibration control of steel truss bridges.

  6. Development of seismic design method for piping system supported by elastoplastic damper. 3. Vibration test of three-dimensional piping model and its response analysis

    International Nuclear Information System (INIS)

    Namita, Yoshio; Kawahata, Jun-ichi; Ichihashi, Ichiro; Fukuda, Toshihiko.

    1995-01-01

    Component and piping systems in current nuclear power plants and chemical plants are designed to employ many supports to maintain safety and reliability against earthquakes. However, these supports are rigid and have a slight energy-dissipating effect. It is well known that applying high-damping supports to the piping system is very effective for reducing the seismic response. In this study, we investigated the design method of the elastoplastic damper [energy absorber (EAB)] and the seismic design method for a piping system supported by the EAB. Our final goal is to develop technology for applying the EAB to the piping system of an actual plant. In this paper, the vibration test results of the three-dimensional piping model are presented. From the test results, it is confirmed that EAB has a large energy-dissipating effect and is effective in reducing the seismic response of the piping system, and that the seismic design method for the piping system, which is the response spectrum mode superposition method using each modal damping and requires iterative calculation of EAB displacement, is applicable for the three-dimensional piping model. (author)

  7. Systems and methods for self-synchronized digital sampling

    Science.gov (United States)

    Samson, Jr., John R. (Inventor)

    2008-01-01

    Systems and methods for self-synchronized data sampling are provided. In one embodiment, a system for capturing synchronous data samples is provided. The system includes an analog to digital converter adapted to capture signals from one or more sensors and convert the signals into a stream of digital data samples at a sampling frequency determined by a sampling control signal; and a synchronizer coupled to the analog to digital converter and adapted to receive a rotational frequency signal from a rotating machine, wherein the synchronizer is further adapted to generate the sampling control signal, and wherein the sampling control signal is based on the rotational frequency signal.

  8. Prototype of time digitizing system for BESⅢ endcap TOF upgrade

    International Nuclear Information System (INIS)

    Cao Ping; Sun Weijia; Fan Huanhuan; Wang Siyu; Liu Shubin; An Qi; Ji Xiaolu

    2014-01-01

    The prototype of a time digitizing system for the BESⅢ endcap TOF (ETOF) upgrade is introduced in this paper. The ETOF readout electronics has a distributed architecture. Hit signals from the multi-gap resistive plate chamber (MRPC) are signaled as LVDS by front-end electronics (FEE) and are then sent to the back-end time digitizing system via long shield differential twisted pair cables. The ETOF digitizing system consists of two VME crates, each of which contains modules for time digitization, clock, trigger, fast control, etc. The time digitizing module (TDIG) of this prototype can support up to 72 electrical channels for hit information measurement. The fast control (FCTL) module can operate in barrel or endcap mode. The barrel FCTL fans out fast control signals from the trigger system to the endcap FCTLs, merges data from the endcaps and then transfers to the trigger system. Without modifying the barrel TOF (BTOF) structure, this time digitizing architecture benefits from improved ETOF performance without degrading the BTOF performance. Lab experiments show that the time resolution of this digitizing system can be lower than 20 ps, and the data throughput to the DAQ can be about 92 Mbps. Beam experiments show that the total time resolution can be lower than 45 ps. (authors)

  9. Implementation considerations for digital control systems in power plants: Final report

    International Nuclear Information System (INIS)

    Shah, S.C.; Lehman, L.L.; Sarchet, M.M.

    1988-09-01

    Conversion of nuclear power plants fron analog to digital control systems will require careful design, testing, and integration of the control algorithms, the software which implements the algorithms, the digital instrumentation, the digital communications network, and analog/digital device interfaces. Digital control systems are more flexible than their analog counterparts, and therefore greater attention must be paid by the customer to all stages of the control system design process. This flexibility also provides the framework for development of significant safety and reliability are inherant aspects of the chosen design processes. Digital control algorithms are capable of improving their performance by on-line self-tuning of the control parameters. It is therefore incumbant on system designers to choose self-tuning algorithms for power plant control. Implementation of these algorithms in software required a careful software design and development process to minimize errors in interpretation of the engineering design and prevent the inclusion of programming errors during software production. Digital control system and communications software must exhibit sufficient ''fault tolerance'' to maintain some level of safe plant operation or execute a safe plant shutdown in the event of both hard equipment failures and the appearance of software design faults. A number of standardized digital communications protocols are available to designers of digital control systems. These standardized digital communications protocols provide reliable fault tolerant communication between all digital elements of the plant control system and can be implemented redundantly to further enhance power plant operational safety. 5 refs., 11 figs., 1 tab

  10. Digital image display system for emergency room

    International Nuclear Information System (INIS)

    Murry, R.C.; Lane, T.J.; Miax, L.S.

    1989-01-01

    This paper reports on a digital image display system for the emergency room (ER) in a major trauma hospital. Its objective is to reduce radiographic image delivery time to a busy ER while simultaneously providing a multimodality capability. Image storage, retrieval, and display will also be facilitated with this system. The system's backbone is a token-ring network of RISC and personal computers. The display terminals are higher- function RISC computers with 1,024 2 color or gray-scale monitors. The PCs serve as administrative terminals. Nuclear medicine, CT, MR, and digitized film images are transferred to the image display system

  11. Pengaruh Digital Marketing System, Terhadap Daya Saing Penjualan Susu Kambing Etawa

    Directory of Open Access Journals (Sweden)

    Akh Fawaid

    2017-06-01

    Full Text Available In this research, the researcher wanted to know the influence of sales of goat milk Etawa using Digital Marketing System (Digital Sales system and know the difference of conventional sales with Digital Marketing System. Easness Aspect of knowing the product, the content of Product, Benefits of product, and accelerate service process to consumer, Became one of the reasons Digital Marketing System used against Etawa Goat's milk sales. So it needs to be done experiment, to know the whole level of sales influence and competitiveness of Etawa Goat Milk Sales using Digital Marketing System and doing Comparison to sales using conventional system. The research method used is descriptive qualitative research method. The results showed, Digital Marketing System has a very high influence on sales of goat milk Etawa, compared using conventional system. One of them, on the marketing process, convenience and ease of consumers obtain product information, until the transaction process.

  12. Essential Requirements for Digital Annotation Systems

    Directory of Open Access Journals (Sweden)

    ADRIANO, C. M.

    2012-06-01

    Full Text Available Digital annotation systems are usually based on partial scenarios and arbitrary requirements. Accidental and essential characteristics are usually mixed in non explicit models. Documents and annotations are linked together accidentally according to the current technology, allowing for the development of disposable prototypes, but not to the support of non-functional requirements such as extensibility, robustness and interactivity. In this paper we perform a careful analysis on the concept of annotation, studying the scenarios supported by digital annotation tools. We also derived essential requirements based on a classification of annotation systems applied to existing tools. The analysis performed and the proposed classification can be applied and extended to other type of collaborative systems.

  13. Image quality in conventional film screen system, digital phosphor storage plate mammography in magnification technique and digital mammography in CCD-technique

    International Nuclear Information System (INIS)

    Schulz-Wendtland, R.; Aichinger, U.; Boehner, C.; Dobritz, M.; Bautz, W.; Saebel, M.

    2000-01-01

    Purpose: Comparison of image quality between conventional film screen system, digital phosphor storage plate mammography in magnification technique and digital mammography in CCD-technique. Materials and Methods: Radiograms of a RMI-mammography phantom were acquired using a conventional film screen system, two digital storage plate systems and two digital systems in CCD-technique. Additionally, the radiograms of one digital phosphor storage plate system were post-processed emphasizing contrast and included in the comparison. Results: The detectability of details was the best with the digital mammography in CCD-technique in comparison with the conventional film screen technique resp. digital phosphor storage plate in magnification technique. Conclusions: Based on these results there is the possibility to replace the conventional film screen system by further studies - this has to be confirmed. (orig.) [de

  14. A multi-channel waveform digitizer system

    International Nuclear Information System (INIS)

    Bieser, F.; Muller, W.F.J.

    1990-01-01

    The authors report on the design and performance of a multichannel waveform digitizer system for use with the Multiple Sample Ionization Chamber (MUSIC) Detector at the Bevalac. 128 channels of 20 MHz Flash ADC plus 256 word deep memory are housed in a single crate. Digital thresholds and hit pattern logic facilitate zero suppression during readout which is performed over a standard VME bus

  15. Multibody dynamical modeling for spacecraft docking process with spring-damper buffering device: A new validation approach

    Science.gov (United States)

    Daneshjou, Kamran; Alibakhshi, Reza

    2018-01-01

    In the current manuscript, the process of spacecraft docking, as one of the main risky operations in an on-orbit servicing mission, is modeled based on unconstrained multibody dynamics. The spring-damper buffering device is utilized here in the docking probe-cone system for micro-satellites. Owing to the impact occurs inevitably during docking process and the motion characteristics of multibody systems are remarkably affected by this phenomenon, a continuous contact force model needs to be considered. Spring-damper buffering device, keeping the spacecraft stable in an orbit when impact occurs, connects a base (cylinder) inserted in the chaser satellite and the end of docking probe. Furthermore, by considering a revolute joint equipped with torsional shock absorber, between base and chaser satellite, the docking probe can experience both translational and rotational motions simultaneously. Although spacecraft docking process accompanied by the buffering mechanisms may be modeled by constrained multibody dynamics, this paper deals with a simple and efficient formulation to eliminate the surplus generalized coordinates and solve the impact docking problem based on unconstrained Lagrangian mechanics. By an example problem, first, model verification is accomplished by comparing the computed results with those recently reported in the literature. Second, according to a new alternative validation approach, which is based on constrained multibody problem, the accuracy of presented model can be also evaluated. This proposed verification approach can be applied to indirectly solve the constrained multibody problems by minimum required effort. The time history of impact force, the influence of system flexibility and physical interaction between shock absorber and penetration depth caused by impact are the issues followed in this paper. Third, the MATLAB/SIMULINK multibody dynamic analysis software will be applied to build impact docking model to validate computed results and

  16. Single Bit Radar Systems for Digital Integration

    OpenAIRE

    Bjørndal, Øystein

    2017-01-01

    Small, low cost, radar systems have exciting applications in monitoring and imaging for the industrial, healthcare and Internet of Things (IoT) sectors. We here explore, and show the feasibility of, several single bit square wave radar architectures; that benefits from the continuous improvement in digital technologies for system-on-chip digital integration. By analysis, simulation and measurements we explore novel and harmonic-rich continuous wave (CW), stepped-frequency CW (SFCW) and freque...

  17. Effectiveness of multi tuned liquid dampers with slat screens for reducing dynamic responses of structures

    Science.gov (United States)

    Nguyen, T. P.; Pham, D. T.; Ngo, K. T.

    2018-04-01

    Reducing vibration in structures under lateral load always attracts many researchers in during pastime, hence the mainly purpose of paper analyzes effectiveness of multiple-tuned liquid dampers for reducing dynamic responses of structures under ground acceleration of earthquakes. In this study, the multi-tuned liquid damper with slat screens (M-TLDWSS) is considered in detail for analyzing dynamic response of multi-degrees of freedom structure due to earthquake, which is more different previous studies. Then, the general equation of motion of the structure and M-TLDWSS under ground acceleration of earthquake is established based on dynamic balance of principle and solved by numerical method in the time domain. The effects of characteristic parameters of M-TLDWSS on dynamic response of the structure are investigated. The results obtained in this study demonstrate that the M-TLDWSS has significantly effectiveness for reducing dynamic response of the structure.

  18. Digital radiation monitor system

    International Nuclear Information System (INIS)

    Quan Jinhu; Zhai Yongchun; Guan Junfeng; Ren Dangpei; Ma Zhiyuan

    2003-01-01

    The article introduced digital radiation monitor system. The contents include: how to use advanced computer net technology to establish equipment net for nuclear facility, how to control and manage measuring instruments on field equipment net by local area net, how to manage and issue radiation monitoring data by internet

  19. Design of a power amplifier for the LAMPF proton storage ring transverse damper system

    International Nuclear Information System (INIS)

    Lunsford, J.S.

    1981-01-01

    A power amplifier has been designed to drive the 50-Ω stripline deflection structures in the transverse active damper of the Los Alamos 800-MeV Proton Storage Ring (PSR). The unit will provide 600-V peak-to-peak with a dc-to-100-MHz bandwidth. Other important characteristics include < 40-ns delay time, 50-dB voltage gain, and 4-ns risetime with < 5% overshoot and ringing. Because of the current-drive properties of the amplifier, two amplifiers could be combined to provide over 1000-V peak-to-peak into 50 Ω, with very little bandwidth degradation. Components in the power amplifier that represent new designs are a 20-tube distributed-amplifier output stage; a driver stage, using VMOS FET and bipolar transistors; a high-voltage probe, with good dc stability and 150-MHz bandwidth; a transient suppressor circuit, using PIN diodes to protect the transistorized drivers from tube arcing; a nonlinear amplifier to compensate for the nonlinear characteristics of the distributed amplifier; and a first-fail indicator circuit to aid in locating the prime causes of equipment failures

  20. Digital PIV (DPIV) Software Analysis System

    Science.gov (United States)

    Blackshire, James L.

    1997-01-01

    A software package was developed to provide a Digital PIV (DPIV) capability for NASA LaRC. The system provides an automated image capture, test correlation, and autocorrelation analysis capability for the Kodak Megaplus 1.4 digital camera system for PIV measurements. The package includes three separate programs that, when used together with the PIV data validation algorithm, constitutes a complete DPIV analysis capability. The programs are run on an IBM PC/AT host computer running either Microsoft Windows 3.1 or Windows 95 using a 'quickwin' format that allows simple user interface and output capabilities to the windows environment.

  1. Theoretical study of the flow in a fluid damper containing high viscosity silicone oil: Effects of shear-thinning and viscoelasticity

    Science.gov (United States)

    Syrakos, Alexandros; Dimakopoulos, Yannis; Tsamopoulos, John

    2018-03-01

    The flow inside a fluid damper where a piston reciprocates sinusoidally inside an outer casing containing high-viscosity silicone oil is simulated using a finite volume method, at various excitation frequencies. The oil is modeled by the Carreau-Yasuda (CY) and Phan-Thien and Tanner (PTT) constitutive equations. Both models account for shear-thinning, but only the PTT model accounts for elasticity. The CY and other generalised Newtonian models have been previously used in theoretical studies of fluid dampers, but the present study is the first to perform full two-dimensional (axisymmetric) simulations employing a viscoelastic constitutive equation. It is found that the CY and PTT predictions are similar when the excitation frequency is low, but at medium and higher frequencies, the CY model fails to describe important phenomena that are predicted by the PTT model and observed in experimental studies found in the literature, such as the hysteresis of the force-displacement and force-velocity loops. Elastic effects are quantified by applying a decomposition of the damper force into elastic and viscous components, inspired from large amplitude oscillatory shear theory. The CY model also overestimates the damper force relative to the PTT model because it underpredicts the flow development length inside the piston-cylinder gap. It is thus concluded that (a) fluid elasticity must be accounted for and (b) theoretical approaches that rely on the assumption of one-dimensional flow in the piston-cylinder gap are of limited accuracy, even if they account for fluid viscoelasticity. The consequences of using lower-viscosity silicone oil are also briefly examined.

  2. Digital control in LLRF system for CYCIAE-100 cyclotron

    Energy Technology Data Exchange (ETDEWEB)

    Yin, Zhiguo, E-mail: bitbearAT@hotmail.com; Fu, Xiaoliang; Ji, Bin; Zhang, Tianjue; Wang, Chuan

    2016-05-21

    As a driven accelerator, the CYCIAE-100 cyclotron is designed by China Institute of Atomic Energy for the Beijing Radio Ion-beam Facility project. The cyclotron RF system is designed to use two RF power sources of 100 kW to drive two half-wavelength cavities respectively. Two Dee accelerating electrodes are kept separately from each other inside the cyclotron, while their accelerating voltages are maintained in phase by the efforts of LLRF control. An analog–digital hybrid LLRF system has been developed to achieve cavity tuning control, dee voltage amplitude and phase stabilization etc. The analog subsystems designs are focused on RF signal up/down conversion, tuning control, and dee voltage regulation. The digital system provides an RF signal source, aligns the cavity phases and maintains a Finite State Machine. The digital parts combine with the analog functions to provide the LLRF control. A brief system hardware introduction will be given in this paper, followed by the review of several major characteristics of the digital control in the 100 MeV cyclotron LLRF system. The commissioning is also introduced, and most of the optimization during the process was done by changing the digital parts.

  3. Agent and multi-Agent systems in distributed systems digital economy and e-commerce

    CERN Document Server

    Hartung, Ronald

    2013-01-01

    Information and communication technology, in particular artificial intelligence, can be used to support economy and commerce using digital means. This book is about agents and multi-agent distributed systems applied to digital economy and e-commerce to meet, improve, and overcome challenges in the digital economy and e-commerce sphere. Agent and multi-agent solutions are applied in implementing real-life, exciting developments associated with the need to eliminate problems of distributed systems.   The book presents solutions for both technology and applications, illustrating the possible uses of agents in the enterprise domain, covering design and analytic methods, needed to provide a solid foundation required for practical systems. More specifically, the book provides solutions for the digital economy, e-sourcing clusters in network economy, and knowledge exchange between agents applicable to online trading agents, and security solutions to both digital economy and e-commerce. Furthermore, it offers soluti...

  4. Clinical application of digital angiographic system DIGITEX2400

    Energy Technology Data Exchange (ETDEWEB)

    Kawai, Masumi; Tanaka, Shuji; Fujino, Yoshiyuki; Yasumi, Masayuki (Shimadzu Corp., Kyoto (Japan))

    1992-10-01

    Digital angiography (DA) has been of widespread use clinically, and it has attracted considerable attention in angiographic examination today. And under the condition of the spread of interventional angiography, not only high quality image but also ease of operation are required to the system. The clinical usefullness of digital angiographic system DIGITEX2400 are reported in this paper. (author).

  5. Clinical application of digital angiographic system DIGITEX2400

    International Nuclear Information System (INIS)

    Kawai, Masumi; Tanaka, Shuji; Fujino, Yoshiyuki; Yasumi, Masayuki

    1992-01-01

    Digital angiography (DA) has been of widespread use clinically, and it has attracted considerable attention in angiographic examination today. And under the condition of the spread of interventional angiography, not only high quality image but also ease of operation are required to the system. The clinical usefullness of digital angiographic system DIGITEX2400 are reported in this paper. (author)

  6. Experiences upgrading a fluoroscopic system to digital specifications

    International Nuclear Information System (INIS)

    Fox, T.; Fenzl, G.

    1995-01-01

    In 1993, an undertable fluoroscopic system was retrofitted with a Fluorospot HC digital system at the radiological clinic of the Knappschaftskrankenhaus in Puettlingen, Germany. The experiences and possibilities resulting from this digital upgrade are related by the authors, whose narrative is also accompanied by examples of clinical images. The costs involved are also discussed in this article. (orig.)

  7. Digital Signal Processing for Optical Coherent Communication Systems

    DEFF Research Database (Denmark)

    Zhang, Xu

    spectrum narrowing tolerance 112-Gb/s DP-QPSK optical coherent systems using digital adaptive equalizer. The demonstrated results show that off-line DSP algorithms are able to reduce the bit error rate (BER) penalty induced by signal spectrum narrowing. Third, we also investigate bi...... wavelength division multiplex (U-DWDM) optical coherent systems based on 10-Gbaud QPSK. We report U-DWDM 1.2-Tb/s QPSK coherent system achieving spectral efficiency of 4.0-bit/s/Hz. In the experimental demonstration, digital decision feed back equalizer (DFE) algorithms and a finite impulse response (FIR......In this thesis, digital signal processing (DSP) algorithms are studied to compensate for physical layer impairments in optical fiber coherent communication systems. The physical layer impairments investigated in this thesis include optical fiber chromatic dispersion, polarization demultiplexing...

  8. Fully Digital Chaotic Differential Equation-based Systems And Methods

    KAUST Repository

    Radwan, Ahmed Gomaa Ahmed; Zidan, Mohammed A.; Salama, Khaled N.

    2012-01-01

    Various embodiments are provided for fully digital chaotic differential equation-based systems and methods. In one embodiment, among others, a digital circuit includes digital state registers and one or more digital logic modules configured to obtain a first value from two or more of the digital state registers; determine a second value based upon the obtained first values and a chaotic differential equation; and provide the second value to set a state of one of the plurality of digital state registers. In another embodiment, a digital circuit includes digital state registers, digital logic modules configured to obtain outputs from a subset of the digital shift registers and to provide the input based upon a chaotic differential equation for setting a state of at least one of the subset of digital shift registers, and a digital clock configured to provide a clock signal for operating the digital shift registers.

  9. Fully Digital Chaotic Differential Equation-based Systems And Methods

    KAUST Repository

    Radwan, Ahmed Gomaa Ahmed

    2012-09-06

    Various embodiments are provided for fully digital chaotic differential equation-based systems and methods. In one embodiment, among others, a digital circuit includes digital state registers and one or more digital logic modules configured to obtain a first value from two or more of the digital state registers; determine a second value based upon the obtained first values and a chaotic differential equation; and provide the second value to set a state of one of the plurality of digital state registers. In another embodiment, a digital circuit includes digital state registers, digital logic modules configured to obtain outputs from a subset of the digital shift registers and to provide the input based upon a chaotic differential equation for setting a state of at least one of the subset of digital shift registers, and a digital clock configured to provide a clock signal for operating the digital shift registers.

  10. ISSUES ASSOCIATED WITH PROBABILISTIC FAILURE MODELING OF DIGITAL SYSTEMS

    International Nuclear Information System (INIS)

    CHU, T.L.; MARTINEZ-GURIDI, G.; LIHNER, J.; OVERLAND, D.

    2004-01-01

    The current U.S. Nuclear Regulatory Commission (NRC) licensing process of instrumentation and control (I and C) systems is based on deterministic requirements, e.g., single failure criteria, and defense in depth and diversity. Probabilistic considerations can be used as supplements to the deterministic process. The National Research Council has recommended development of methods for estimating failure probabilities of digital systems, including commercial off-the-shelf (COTS) equipment, for use in probabilistic risk assessment (PRA). NRC staff has developed informal qualitative and quantitative requirements for PRA modeling of digital systems. Brookhaven National Laboratory (BNL) has performed a review of the-state-of-the-art of the methods and tools that can potentially be used to model digital systems. The objectives of this paper are to summarize the review, discuss the issues associated with probabilistic modeling of digital systems, and identify potential areas of research that would enhance the state of the art toward a satisfactory modeling method that could be integrated with a typical probabilistic risk assessment

  11. INFLUENCE OF THE STORY STIFFNESS OF REINFORCED CONCRETE FRAME WITH PROPORTIONAL HYSTERETIC DAMPERS ON THE SEISMIC RESPONSE INFLUENCIA DE LA RIGIDEZ DE PISO DE PÓRTICOS DE CONCRETO REFORZADO CON DISIPADORES HISTERÉTICOS PROPORCIONALES SOBRE LA RESPUESTA SÍSMICA INFLUÊNCIA DA RIGIDEZ DE ANDAR DE PÓRTICOS DE CONCRETO REFORÇADO COM DISIPADORES HISTERÉTICOS PROPORCIONAIS SOBRE A RESPOSTA SÍSMICA

    OpenAIRE

    Juan Andrés Oviedo

    2012-01-01

    This paper investigates the influence of the story stiffness of reinforced concrete (R/C) frame on the seismic response of R/C buildings with proportional hysteretic dampers. For this purpose, non-linear time-history analyses were conducted on a series of multi-degree-of-freedom system models that include a wide range of structural parameters and vertical distributions of story stiffnesses and strengths of R/C main frame and dampers. Although the basic purpose of damper installation is to red...

  12. The development of ZPRL digital control system

    International Nuclear Information System (INIS)

    Hsu, Jin-Den; Yang, Sheau-Yieh; Shieh, Der-Jhy.

    1992-01-01

    Zero Power Reactor at Lung-Tan (ZPRL) is a small open-pool type research reactor located at Lung-Tan, Taiwan. The reactor achieved its first criticality in 1971. An analog control system has been used for almost over 20 years and the power regulating function is found gradually out of order. Therefore, we decided to develop a digital control system to replace the existing analog one. A prototype system has been developed and under on-line test now. The proposed ZPRL digital control system consists of three personal computers. These computers are used as (1) operator console, (2) data acquisition and control system, and (3) auxiliary and backup system. The operator console contains all the man-machine interface functions in the form of graphic display. The data acquisition and control system converts the analog signals into digital ones and feeds to the other two computers. The auxiliary and backup system normally emulates a strip chart recorder for the linear and logarithmic neutron powers and also acts as a transient recorder to keep the trace of the operating conditions on demand or when the reactor scrams. On-line test shows that the system does assure a satisfactory performance. It is not only as good as the analog system but also has the advantages of flexibility, testibility, and a user friendly man-machine interface. (author)

  13. The cyclical monitoring system for digital power supplies at SSRF

    International Nuclear Information System (INIS)

    Tang Junlong; Li Deming; Shen Tianjian

    2009-01-01

    Based on available digital PS testing system and long-distance monitoring hardwares, the cyclical monitoring system for digital power supplies (PS) was developed at SSRF. Two models, i.e.long-distance cyclical monitoring and local cyclical monitoring, were established. The software developed in LabVIEW language was applied to the two models without any user interface modification. The user interface is simple. The system is suitable for debugging the digital PSs during long-distance monitoring and examining the performance. The long-distance model imitates the digital PSs' status for fault analysis and communication between the digital PS and the centre control room. The local model simultaneously examines stability of 18 new PSs for 24 h, monitors the PS controller, and detects malfunction. Parameters and status of the controller can be stored in Excel or Text file. The two models have been used at SSRF for monitoring the digital PSs. (authors)

  14. Manufacture of Platform Prototype for Digital Safety System

    International Nuclear Information System (INIS)

    Lee, S. Y.; Kim, J. S.; Kim, J. M.

    2010-01-01

    Unit controller is a basic unit of digital safety system platform prototype. The typical unit controller is comprised of CPB(CPU board), CMB(communication board), AIB(Analog input board), AOB(Analog output board), CIB(contact input board), COB(contact output board), and a subrack. It is developed according to H/W development procedure and S/W development life cycle. A digital safety system(for example, plant protection system) is the assemblies of unit controllers. CPB performs the function of each system. DSP(digital signal processor) is built in CPB. CMB is responsible for communication between unit controllers. NSD(Network Switching Device) exchanges data between the unit controllers. Each unit controller of the platform are connected to NSD through CMB. Reliability analyses on unit controller and NSD are performed. These reliability data are used as input of technical validation

  15. A customized digital monitoring and display system for nonpower reactors

    International Nuclear Information System (INIS)

    Ficaro, E.P.; Wehe, D.K.

    1989-01-01

    A digital data acquisition system for monitoring plant variables has been designed and implemented at the University of Michigan's Ford Nuclear Reactor (FNR), a 2-MW open-pool research reactor. The digital data provided by this system will be useful for: improved operator training, real-time experimental calculations, noise analysis, closed-loop control, and expert system applications. This paper describes the analog-to-digital (A/D) transitions and the associated applications and benefits experienced

  16. An experimental study on pseudoelasticity of a NiTi-based damper for civil applications

    Science.gov (United States)

    Nespoli, Adelaide; Bassani, Enrico; Della Torre, Davide; Donnini, Riccardo; Villa, Elena; Passaretti, Francesca

    2017-10-01

    In this work, a pseudoelastic damper composed by NiTi wires is tested at 0.5, 1 and 2 Hz for 1000 mechanical cycles. The damping performances were evaluated by three key parameters: the damping capacity, the dissipated energy per cycle and the maximum force. During testing, the temperature of the pseudoelastic elements was registered as well. Results show that the damper assures a bi-directional motion throughout the 1000 cycles together with the maintenance of the recentering. It was observed a stabilization process in the first 50 mechanical cycles, where the key parameters reach stable values; in particular it was found that the damping capacity and the dissipated energy both decrease with frequency. Besides, the mean temperature of the pseudoleastic elements reaches a stable value during tests and confirms the different response of the pseudoelastic wires accordingly with the specific length and stain. Finally, interesting thermal effects were observed at 1 and 2 Hz: at these frequencies and at high strains, the maximum force increases but the temperature of the NiTi wire decreases being in contraddiction with the Clausius-Clapeyron law.

  17. Practical Maintenance of Digital Systems: Guidance to Maximize the Benefits of Digital Technology for the Maintenance of Digital Systems and Plant Equipment

    Energy Technology Data Exchange (ETDEWEB)

    Hill, D; Scarola, K

    2004-10-30

    This report presents detailed guidance for the maintenance and testing of modern digital systems. The guidance provides practical means for plants to take advantage of the increased diagnostic and self-test capabilities of these systems. It helps plants avoid mistakes in design and installation that could lead to increased maintenance burden and decreased system reliability and availability.

  18. Practical Maintenance of Digital Systems. Guidance to Maximize the Benefits of Digital Technology for the Maintenance of Digital Systems and Plant Equipment

    International Nuclear Information System (INIS)

    Hill, D.; Scarola, K.

    2004-01-01

    This report presents detailed guidance for the maintenance and testing of modern digital systems. The guidance provides practical means for plants to take advantage of the increased diagnostic and self-test capabilities of these systems. It helps plants avoid mistakes in design and installation that could lead to increased maintenance burden and decreased system reliability and availability

  19. Simulation of Wireless Digital Communication Systems

    Directory of Open Access Journals (Sweden)

    A. Mohammed

    2004-12-01

    Full Text Available Due to the explosive demands for high speed wireless services, suchas wireless Internet, email and cellular video conferencing, digitalwireless communications has become one of the most exciting researchtopics in electrical and electronic engineering field. The never-endingdemand for such personal and multimedia services, however, demandstechnologies operating at higher data rates and broader bandwidths. Inaddition, the complexity of wireless communication and signalprocessing systems has grown considerably during the past decade.Therefore, powerful computer­aided techniques are required for theprocess of modeling, designing, analyzing and evaluating theperformance of digital wireless communication systems. In this paper wediscuss the basic propagation mechanisms affecting the performance ofwireless communication systems, and present a simple, powerful andefficient way to simulate digital wireless communication systems usingMatlab. The simulated results are compared with the theoreticalanalysis to validate the simulator. The simulator is useful inevaluating the performance of wireless multimedia services and theassociated signal processing structures and algorithms for current andnext generation wireless mobile communication systems.

  20. A magneto rheological hybrid damper for railway vehicles suspensions

    Directory of Open Access Journals (Sweden)

    Gheorghe GHITA

    2012-09-01

    Full Text Available High speed railway vehicles features a specific lateral oscillation resulting from the coupled lateral displacement and yaw of the wheelset which leads to a sinusoid movement of the wheelset along the track, transferred to the entire vehicle. The amplitude of this oscillation is strongly dependant on vehicle’s velocity. Over a certain value, namely the critical speed, the instability phenomenon so-called hunting occurs. To raise the vehicle’s critical speed different designs of the suspension all leading to a much stiffer vehicle can be envisaged. Different simulations prove that a stiffer central suspension will decrease the passenger’s comfort in terms of lateral accelerations of the carboy. The authors propose a semi-active magneto rheological suspension to improve the vehicle’s comfort at high speeds. The suspension has as executive elements hybrid magneto rheological dampers operating under sequential control strategy type balance logic. Using an original mathematical model for the lateral dynamics of the vehicle the responses of the system with passive and semi-active suspensions are simulated. It is shown that the semi-active suspension can improve the vehicle performances.

  1. Development of digital subtraction system DAR-1200

    International Nuclear Information System (INIS)

    Kawai, Masumi; Shimizu, Yasumitsu; Ozaki, Takeshi; Sawada, Hiroshi; Uzuyama, Kazuhiro; Nishioka, Hiroyuki

    1989-01-01

    Digital subtraction angiography (DSA) has been of widespread use clinically, and it has attracted considerable attention in angiographic examination today. The merits of Shimadzu high resolution digital subtraction system DAR-1200 are reported in this paper. Furthermore, the principle and clinical usefullness of a new method of DSA called the Peak-Hold DSA are explained especially in details. (author)

  2. Digital Sliding Mode Control of Anti-Lock Braking System

    Directory of Open Access Journals (Sweden)

    MITIC, D. B.

    2013-02-01

    Full Text Available The control of anti-lock braking system is a great challenge, because of the nonlinear and complex characteristics of braking dynamics, unknown parameters of vehicle environment and system parameter variations. Using some of robust control methods, such as sliding mode control, can be a right solution for these problems. In this paper, we introduce a novel approach to design of ABS controllers, which is based on digital sliding mode control with only input/output measurements. The relay term of the proposed digital sliding mode control is filtered through digital integrator, reducing the chattering phenomenon in that way, and the additional signal of estimated modelling error is introduced into control algorithm to enhance the system steady-state accuracy. The given solution was verified in real experimental framework and the obtained results were compared with the results of implementation of two other digital sliding mode control algorithms. It is shown that it gives better system response, higher steady-state accuracy and smaller chattering.

  3. Digital avionics systems - Overview of FAA/NASA/industry-wide briefing

    Science.gov (United States)

    Larsen, William E.; Carro, Anthony

    1986-01-01

    The effects of incorporating digital technology into the design of aircraft on the airworthiness criteria and certification procedures for aircraft are investigated. FAA research programs aimed at providing data for the functional assessment of aircraft which use digital systems for avionics and flight control functions are discussed. The need to establish testing, assurance assessment, and configuration management technologies to insure the reliability of digital systems is discussed; consideration is given to design verification, system performance/robustness, and validation technology.

  4. Experience with digital acoustic monitoring systems for PWRs and BWRs

    International Nuclear Information System (INIS)

    Olma, B.J.

    1998-01-01

    Substantial progress could be reached both in system technics and in application of digital acoustic monitoring systems for assessing mechanical integrity of reactor primary systems. For the surveillance of PWRs and BWRs during power operation of the plants, acoustic signals of Loose Parts Monitoring System sensors are continuously monitored for signal bursts associated with metallic impacts. ISTec/GRS experience with its digital systems MEDEA and RAMSES has shown that acoustic signature analysis is very successful for detecting component failures at an early stage. Methods for trending and classification of digital burst signals are shown, experience with their practical use will be presented. (author)

  5. Advantages of digital radiography: The DSI system

    International Nuclear Information System (INIS)

    Drouillard, J.

    1990-01-01

    The experience gained over a period of several months, applying the digital and image-enhanced radiography with the DSI system for examination of some hundreds of patients, has confirmed in our eyes the system's diagnostic and economic efficiency, and the important achievement of radiation dose abatement. Looking at the current results and improvements under way (Release 2), there is reason enough to support an extension of the range of indications, especially regarding arteriography and interventional radiography. According to our experience, the DSI system meets the requirements of a modern radiology department: reduction of operating costs, limitation of radiation dose, efficiency enhancement by digital imaging. (orig.) [de

  6. Common Cause Failure Analysis for the Digital Plant Protection System

    International Nuclear Information System (INIS)

    Kagn, Hyun Gook; Jang, Seung Cheol

    2005-01-01

    Safety-critical systems such as nuclear power plants adopt the multiple-redundancy design in order to reduce the risk from the single component failure. The digitalized safety-signal generation system is also designed based on the multiple-redundancy strategy which consists of more redundant components. The level of the redundant design of digital systems is usually higher than those of conventional mechanical systems. This higher redundancy would clearly reduce the risk from the single failure of components, but raise the importance of the common cause failure (CCF) analysis. This research aims to develop the practical and realistic method for modeling the CCF in digital safety-critical systems. We propose a simple and practical framework for assessing the CCF probability of digital equipment. Higher level of redundancy causes the difficulty of CCF analysis because it results in impractically large number of CCF events in the fault tree model when we use conventional CCF modeling methods. We apply the simplified alpha-factor (SAF) method to the digital system CCF analysis. The precedent study has shown that SAF method is quite realistic but simple when we consider carefully system success criteria. The first step for using the SAF method is the analysis of target system for determining the function failure cases. That is, the success criteria of the system could be derived from the target system's function and configuration. Based on this analysis, we can calculate the probability of single CCF event which represents the CCF events resulting in the system failure. In addition to the application of SAF method, in order to accommodate the other characteristics of digital technology, we develop a simple concept and several equations for practical use

  7. Wire Mesh Dampers for Semi-Floating Ring Bearings in Automotive Turbochargers: Measurements of Structural Stiffness and Damping Parameters

    Directory of Open Access Journals (Sweden)

    Keun Ryu

    2018-04-01

    Full Text Available The current work introduces a new semi-floating ring bearing (SFRB system developed for improving the rotordynamic and vibration performance of automotive turbochargers (TCs at extreme operation conditions, such as high temperature, severe external force excitation, and large rotor imbalance. The new bearing design replaces outer oil films, i.e., squeeze film dampers (SFDs, in TC SFRBs with wire mesh dampers (WMDs. This SFRB configuration integrating WMDs aims to implement reliable mechanical components, as an inexpensive and simple alternative to SFDs, with consistent and superior damping capability, as well as predictable forced performance. Since WMDs are in series with the inner oil films of SFRBs, experimentally determined force coefficients of WMDs are of great importance in the design process of TC rotor-bearing systems (RBSs. Presently, the measurements of applied static load and ensuing deflection determine the structural stiffnesses of the WMDs. The WMD damping parameters, including dissipated energy, loss factor, and dry friction coefficient, are estimated from the area of the distinctive local hysteresis loop of the load versus WMD displacement data recorded during consecutive loading-unloading cycles as a function of applied preload with a constant amplitude of motion. The changes in WMD loss factor and dry friction coefficient due to increases in preload are more significant for the WMDs with lower density. The present work shows, to date, the most comprehensive measurements of static load characteristics on the WMDs for application into small automotive TCs. More importantly, the extensive test measurements of WMD deflection versus increasing static loads will aid to anchor predictions of future computation model.

  8. Digital signal processing in power system protection and control

    CERN Document Server

    Rebizant, Waldemar; Wiszniewski, Andrzej

    2011-01-01

    Digital Signal Processing in Power System Protection and Control bridges the gap between the theory of protection and control and the practical applications of protection equipment. Understanding how protection functions is crucial not only for equipment developers and manufacturers, but also for their users who need to install, set and operate the protection devices in an appropriate manner. After introductory chapters related to protection technology and functions, Digital Signal Processing in Power System Protection and Control presents the digital algorithms for signal filtering, followed

  9. Safety aspect of digital reactor protection system in Japan

    International Nuclear Information System (INIS)

    Ogiso, Zen-Ichi

    1998-01-01

    It was early in 1980's that the digital controllers were first applied to nuclear power plant in japan. After that, their application area had been expanding gradually, reaching to the overall integrated digital system including the safety system in Kashiwazaki-Kariwa units 6 and 7. The software for computer-based systems has been produced using the graphical language ''POL'' in Japanese nuclear power plants. It is the fundamental principle that the reliability of the software should be assured through the properly managed quality assurance. The POL-based system is fitted to this principle. In applying POL-based systems to safety system, the MITI, Ministry of International Trade and Industry, identified the licensing issues as the regulatory body, while the utilities had developed the digital technology feasible to the safety application. Through the activities, a specific industrial design guide for the software important to safety was established and the adequacy of the technology was certified through the demonstration tests of the integrated system. In the safety examination of the digital reactor protection system of K-6/7, the application of POL were approved. The POL-based systems in nuclear power plants were successful design and production process of the POL-based systems. This paper describes the activities in licensing and maintaining the computer-based systems by the utilities and manufacturers as well as the MITI. (author)

  10. Summary of the preparation of methodology for digital system reliability analysis for PSA purposes

    International Nuclear Information System (INIS)

    Hustak, S.; Babic, P.

    2001-12-01

    The report is structured as follows: Specific features of and requirements for the digital part of NPP Instrumentation and Control (I and C) systems (Computer-controlled digital technologies and systems of the NPP I and C system; Specific types of digital technology failures and preventive provisions; Reliability requirements for the digital parts of I and C systems; Safety requirements for the digital parts of I and C systems; Defence-in-depth). Qualitative analyses of NPP I and C system reliability and safety (Introductory system analysis; Qualitative requirements for and proof of NPP I and C system reliability and safety). Quantitative reliability analyses of the digital parts of I and C systems (Selection of a suitable quantitative measure of digital system reliability; Selected qualitative and quantitative findings regarding digital system reliability; Use of relations among the occurrences of the various types of failure). Mathematical section in support of the calculation of the various types of indices (Boolean reliability models, Markovian reliability models). Example of digital system analysis (Description of a selected protective function and the relevant digital part of the I and C system; Functional chain examined, its components and fault tree). (P.A.)

  11. Vibration Reduction of Wind Turbines Using Tuned Liquid Column Damper Using Stochastic Analysis

    International Nuclear Information System (INIS)

    Alkmim, M H; De Morais, M V G; Fabro, A T

    2016-01-01

    Passive energy dissipation systems encompass a range of materials and devices for enhancing damping. They can be used both for natural hazard mitigation and for rehabilitation of aging or deficient structures. Among the current passive energy dissipation systems, tuned liquid column damper (TLCD), a class of passive control that utilizes liquid in a “U” shape reservoir to control structural vibration of the primary system, has been widely researched in a variety of applications. This paper focus in TLCD application for wind turbines presenting the mathematical model as well as the methods used to overcome the nonlinearity embedded in the system. Optimization methods are used to determine optimum parameters of the system. Additionally, a comparative analysis is done considering the equivalent linearized system and the nonlinear system under random excitation with the goal of compare the nonlinear model with the linear equivalent and investigated the effectiveness of the TLCD. The results are shown using two types of random excitation, a white noise and a first order filters spectrum, the latter presents more satisfactory results since the excitation spectrum is physically more realistic than white noise spectrum model. The results indicate that TLCDs at optimal tuning can significantly dissipate energy of the primary structure between 3 to 11%. (paper)

  12. Modules of the SUMMA system for data readout to the oscillograph, digital display devices and digital printing

    International Nuclear Information System (INIS)

    Bushnin, Yu.B.; Denisenko, A.A.; Dunajtsev, A.F.; Rybakov, V.G.; Sytin, A.N.

    1975-01-01

    The modules of the ''Summa'' system are described which allow outputting of information to an oscilloscope, a digital tableau, and a digital printing mechanism; they are: a digital-analog converter, a converter that converts a binary code to a binary-decimal code, a digital display module, a block for outputting to a digital printing mechanism, and a block for stipulating the programs during information outputting. The block diagrams of the modules and the block diagram of the information-outputting programs are presented

  13. Design type testing for digital instrumentation and control systems

    International Nuclear Information System (INIS)

    Bastl, W.; Mohns, G.

    1997-01-01

    The design type qualification of digital safety instrumentation and control is outlined. Experience shows that the concepts discussed, derived from codes, guidelines and standards, achieve useful results. It has likewise become clear that the systematics of design type qualification of the hardware components is also applicable to the software components. Design type qualification of the software, a premiere, could be performed unexpectedly smoothly. The hardware design type qualification proved that the hardware as a substrate of functionality and reliability is an issue that demands full attention, as compared to conventional systems. Another insight is that design qualification of digital instrumentation and control systems must include plant-independent systems tests. Digital instrumentation and control systems simply work very differently from conventional control systems, so that this testing modality is inevitable. (Orig./CB) [de

  14. Intermediate probabilistic safety assessment approach for safety critical digital systems

    International Nuclear Information System (INIS)

    Taeyong, Sung; Hyun Gook, Kang

    2001-01-01

    Even though the conventional probabilistic safety assessment methods are immature for applying to microprocessor-based digital systems, practical needs force to apply it. In the Korea, UCN 5 and 6 units are being constructed and Korean Next Generation Reactor is being designed using the digital instrumentation and control equipment for the safety related functions. Korean regulatory body requires probabilistic safety assessment. This paper analyzes the difficulties on the assessment of digital systems and suggests an intermediate framework for evaluating their safety using fault tree models. The framework deals with several important characteristics of digital systems including software modules and fault-tolerant features. We expect that the analysis result will provide valuable design feedback. (authors)

  15. Fast digital feedback control systems for accelerator RF system using FPGA

    International Nuclear Information System (INIS)

    Bagduwal, Pritam Singh; Sharma, Dheeraj; Tiwari, Nitesh; Lad, M.; Hannurkar, P.R.

    2012-01-01

    Feedback control system plays important role for proper injection and acceleration of beam in particle accelerators by providing the required amplitude and phase stability of RF fields in accelerating structures. Advancement in the field of digital technology enables us to develop fast digital feedback control system for RF applications. Digital Low Level RF (LLRF) system offers the inherent advantages of Digital System like flexibility, adaptability, good repeatability and reduced long time drift errors compared to analog system. To implement the feedback control algorithm, I/Q control scheme is used. By properly sampling the down converted IF signal using fast ADC we get accurate feedback signal and also eliminates the need of two separate detectors for amplitude and phase detection. Controller is implemented in Vertex-4 FPGA. Codes for control algorithms which controls the amplitude and phase in all four quadrants with good accuracy are written in the VHDL. I/Q modulator works as common actuator for both amplitude and phase correction. Synchronization between RF, LO and ADC clock is indispensable and has been achieved by deriving the clock and LO signal from RF signal itself. Control system has been successfully tested in lab with phase and amplitude stability better then ±1% and ±1° respectively. High frequency RF signal is down converted to IF using the super heterodyne technique. Super heterodyne principal not only brings the RF signal to the Low IF frequency at which it can be easily processed but also enables us to use the same hardware and software for other RF frequencies with some minor modification. (author)

  16. Reliability Estimation for Digital Instrument/Control System

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Yaguang; Sydnor, Russell [U.S. Nuclear Regulatory Commission, Washington, D.C. (United States)

    2011-08-15

    Digital instrumentation and controls (DI and C) systems are widely adopted in various industries because of their flexibility and ability to implement various functions that can be used to automatically monitor, analyze, and control complicated systems. It is anticipated that the DI and C will replace the traditional analog instrumentation and controls (AI and C) systems in all future nuclear reactor designs. There is an increasing interest for reliability and risk analyses for safety critical DI and C systems in regulatory organizations, such as The United States Nuclear Regulatory Commission. Developing reliability models and reliability estimation methods for digital reactor control and protection systems will involve every part of the DI and C system, such as sensors, signal conditioning and processing components, transmission lines and digital communication systems, D/A and A/D converters, computer system, signal processing software, control and protection software, power supply system, and actuators. Some of these components are hardware, such as sensors and actuators, their failure mechanisms are well understood, and the traditional reliability model and estimation methods can be directly applied. But many of these components are firmware which has software embedded in the hardware, and software needs special consideration because its failure mechanism is unique, and the reliability estimation method for a software system will be different from the ones used for hardware systems. In this paper, we will propose a reliability estimation method for the entire DI and C system reliability using a recently developed software reliability estimation method and a traditional hardware reliability estimation method.

  17. Reliability Estimation for Digital Instrument/Control System

    International Nuclear Information System (INIS)

    Yang, Yaguang; Sydnor, Russell

    2011-01-01

    Digital instrumentation and controls (DI and C) systems are widely adopted in various industries because of their flexibility and ability to implement various functions that can be used to automatically monitor, analyze, and control complicated systems. It is anticipated that the DI and C will replace the traditional analog instrumentation and controls (AI and C) systems in all future nuclear reactor designs. There is an increasing interest for reliability and risk analyses for safety critical DI and C systems in regulatory organizations, such as The United States Nuclear Regulatory Commission. Developing reliability models and reliability estimation methods for digital reactor control and protection systems will involve every part of the DI and C system, such as sensors, signal conditioning and processing components, transmission lines and digital communication systems, D/A and A/D converters, computer system, signal processing software, control and protection software, power supply system, and actuators. Some of these components are hardware, such as sensors and actuators, their failure mechanisms are well understood, and the traditional reliability model and estimation methods can be directly applied. But many of these components are firmware which has software embedded in the hardware, and software needs special consideration because its failure mechanism is unique, and the reliability estimation method for a software system will be different from the ones used for hardware systems. In this paper, we will propose a reliability estimation method for the entire DI and C system reliability using a recently developed software reliability estimation method and a traditional hardware reliability estimation method

  18. Development of regulatory guidance for risk-informing digital system reviews

    International Nuclear Information System (INIS)

    Arndt, S. A.

    2006-01-01

    In 1995, the U.S. Nuclear Regulatory Commission (NRC) issued the Probabilistic Risk Assessment (PRA) Policy Statement, which encourages the increased use of PRA and associated analyses in all regulatory matters to the extent supported by the state-of-the-art in PRA and the data. This policy applies, in part, to the review of digital systems, which offer the potential to improve plant safety and reliability through such features as increased hardware reliability and stability and improved failure detection capability. However, there are presently no universally accepted methods for modeling digital systems in current-generation PRAs. Further, there are ongoing debates among the PRA technical community regarding the level of detail that any digital system reliability model must have to adequately model the complex system interactions that can contribute to digital system failure modes. Moreover, for PRA modeling of digital reactor protection and control systems, direct interactions between system components and indirect interactions through controlled/supervised plant processes may necessitate the use of dynamic PRA methodologies. This situation has led the NRC to consider developing performance based rather than prescriptive regulatory guidance in this area. This paper will discuss the development of this guidance and some preliminary concepts. (authors)

  19. Investigation of physical imaging properties in various digital radiography systems

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Hoi Woun [Dept. of Radiological Science, Baekseok Culture University, Cheonan (Korea, Republic of); Min, Jung Hwan [Dept. of Radiological technology, Shingu University, Seongnam (Korea, Republic of); Yoon, Yong Su [Dept. of Health Sciences, Graduate School of Medical Sciences, Kyushu University, Kyushu (Japan); Kim, Jung Min [Dept. of Health and Environmental Science, College of Health Science, Korea University, Seoul (Korea, Republic of)

    2017-09-15

    We aimed to evaluate the physical imaging properties in various digital radiography systems with charged coupled device (CCD), computed radiography (CR), and indirect flat panel detector (FPD). The imaging properties measured in this study were modulation transfer function (MTF) wiener spectrum (WS), and detective quantum efficiency (DQE) to compare the performance of each digital radiography system. The system response of CCD were in a linear relationship with exposure and that of CR and FPD were proportional to the logarithm of exposure. The MTF of both CR and FPD indicated a similar tendency but in case of CCD, it showed lower MTF than that of CR and FPD. FPD showed the lowest WS and also indicated the highest DQE among three systems. According to the results, digital radiography system with different type of image receptor had its own image characteristics. Therefore, it is important to know the physical imaging characteristics of the digital radiography system accurately to obtain proper image quality.

  20. Long-distance digital signal transfers between trigger system and TOF system of BES III

    International Nuclear Information System (INIS)

    Liu Guangdong; Liu Shubin; An Qi

    2007-01-01

    This article introduces a design of digital signals communication between the trigger system and the TOF system of BES III. The design can support the BES III successfully, which is based on fiber digital communication, FPGA etc. (authors)