WorldWideScience

Sample records for diffusion coefficient mri

  1. Mass diffusion coefficient measurement for vitreous humor using FEM and MRI

    Science.gov (United States)

    Rattanakijsuntorn, Komsan; Penkova, Anita; Sadha, Satwindar S.

    2018-01-01

    In early studies, the ‘contour method’ for determining the diffusion coefficient of the vitreous humor was developed. This technique relied on careful injection of an MRI contrast agent (surrogate drug) into the vitreous humor of fresh bovine eyes, and tracking the contours of the contrast agent in time. In addition, an analytical solution was developed for the theoretical contours built on point source model for the injected surrogate drug. The match between theoretical and experimental contours as a least square fit, while floating the diffusion coefficient, led to the value of the diffusion coefficient. This method had its limitation that the initial injection of the surrogate had to be spherical or ellipsoidal because of the analytical result based on the point-source model. With a new finite element model for the analysis in this study, the technique is much less restrictive and handles irregular shapes of the initial bolus. The fresh bovine eyes were used for drug diffusion study in the vitreous and three contrast agents of different molecular masses: gadolinium-diethylenetriaminepentaacetic acid (Gd-DTPA, 938 Da), non-ionic gadoteridol (Prohance, 559 Da), and bovine albumin conjugated with gadolinium (Galbumin, 74 kDa) were used as drug surrogates to visualize the diffusion process by MRI. The 3D finite element model was developed to determine the diffusion coefficients of these surrogates with the images from MRI. This method can be used for other types of bioporous media provided the concentration profile can be visualized (by methods such as MRI or fluorescence).

  2. The Gini coefficient: a methodological pilot study to assess fetal brain development employing postmortem diffusion MRI

    Energy Technology Data Exchange (ETDEWEB)

    Viehweger, Adrian; Sorge, Ina; Hirsch, Wolfgang [University Hospital Leipzig, Department of Pediatric Radiology, Leipzig (Germany); Riffert, Till; Dhital, Bibek; Knoesche, Thomas R.; Anwander, Alfred [Max Planck Institute for Human Cognitive and Brain Sciences, Leipzig (Germany); Stepan, Holger [University Leipzig, Department of Obstetrics, Leipzig (Germany)

    2014-10-15

    Diffusion-weighted imaging (DWI) is important in the assessment of fetal brain development. However, it is clinically challenging and time-consuming to prepare neuromorphological examinations to assess real brain age and to detect abnormalities. To demonstrate that the Gini coefficient can be a simple, intuitive parameter for modelling fetal brain development. Postmortem fetal specimens(n = 28) were evaluated by diffusion-weighted imaging (DWI) on a 3-T MRI scanner using 60 directions, 0.7-mm isotropic voxels and b-values of 0, 150, 1,600 s/mm{sup 2}. Constrained spherical deconvolution (CSD) was used as the local diffusion model. Fractional anisotropy (FA), apparent diffusion coefficient (ADC) and complexity (CX) maps were generated. CX was defined as a novel diffusion metric. On the basis of those three parameters, the Gini coefficient was calculated. Study of fetal brain development in postmortem specimens was feasible using DWI. The Gini coefficient could be calculated for the combination of the three diffusion parameters. This multidimensional Gini coefficient correlated well with age (Adjusted R{sup 2} = 0.59) between the ages of 17 and 26 gestational weeks. We propose a new method that uses an economics concept, the Gini coefficient, to describe the whole brain with one simple and intuitive measure, which can be used to assess the brain's developmental state. (orig.)

  3. The Gini coefficient: a methodological pilot study to assess fetal brain development employing postmortem diffusion MRI

    International Nuclear Information System (INIS)

    Viehweger, Adrian; Sorge, Ina; Hirsch, Wolfgang; Riffert, Till; Dhital, Bibek; Knoesche, Thomas R.; Anwander, Alfred; Stepan, Holger

    2014-01-01

    Diffusion-weighted imaging (DWI) is important in the assessment of fetal brain development. However, it is clinically challenging and time-consuming to prepare neuromorphological examinations to assess real brain age and to detect abnormalities. To demonstrate that the Gini coefficient can be a simple, intuitive parameter for modelling fetal brain development. Postmortem fetal specimens(n = 28) were evaluated by diffusion-weighted imaging (DWI) on a 3-T MRI scanner using 60 directions, 0.7-mm isotropic voxels and b-values of 0, 150, 1,600 s/mm 2 . Constrained spherical deconvolution (CSD) was used as the local diffusion model. Fractional anisotropy (FA), apparent diffusion coefficient (ADC) and complexity (CX) maps were generated. CX was defined as a novel diffusion metric. On the basis of those three parameters, the Gini coefficient was calculated. Study of fetal brain development in postmortem specimens was feasible using DWI. The Gini coefficient could be calculated for the combination of the three diffusion parameters. This multidimensional Gini coefficient correlated well with age (Adjusted R 2 = 0.59) between the ages of 17 and 26 gestational weeks. We propose a new method that uses an economics concept, the Gini coefficient, to describe the whole brain with one simple and intuitive measure, which can be used to assess the brain's developmental state. (orig.)

  4. Apparent diffusion coefficients of normal uterus in premenopausal women with 3 T MRI

    International Nuclear Information System (INIS)

    Kuang, F.; Chen, Z.; Zhong, Q.; Fu, L.; Ma, M.

    2013-01-01

    Aim: To investigate the apparent diffusion coefficient (ADC) values of the normal uterine cervical zonal structures (cervical epithelium, the junctional zone, and myometrium) during different phases of the menstrual cycle among premenopausal women in different age groups. Materials and methods: Seventy healthy women, who were divided into three age groups (group A, 24 women in their twenties; group B, 23 women in their thirties; group C, 23 women in their forties), underwent 3 T magnetic resonance imaging (MRI) with T2-weighted and diffusion-weighted imaging (DWI) during the mid-proliferative and the mid-secretory phases. Results: The ADC values of each cervical zonal structure were significantly different from one another (p 0.05). Conclusion: ADC values of normal cervical epithelium and the junctional zone change with different phases of the menstrual cycle, which should be taken into consideration when early cervical disease is detected, when monitoring treatment response, and differentiating early tumour recurrence

  5. The use of MRI apparent diffusion coefficient (ADC in monitoring the development of brain infarction

    Directory of Open Access Journals (Sweden)

    Yuan Jian-Jun

    2011-01-01

    Full Text Available Abstract Background To study the rules that apparent diffusion coefficient (ADC changes with time and space in cerebral infarction, and to provide the evidence in defining the infarction stages. Methods 117 work-ups in 98 patients with cerebral infarction (12 hyperacute, 43 acute, 29 subacute, 10 steady, and 23 chronic infarctions were imaged with both conventional MRI and diffusion weighted imaging. The average ADC values, the relative ADC (rADC values, and the ADC values or rADC values from the center to the periphery of the lesion were calculated. Results The average ADC values and the rADC values of hyperacute and acute infarction lesion depressed obviously. rADC values in hyperacute and acute stage was minimized, and increased progressively as time passed and appeared as "pseudonormal" values in approximately 8 to 14 days. Thereafter, rADC values became greater than normal in chronic stage. There was positive correlation between rADC values and time (P Conclusion The ADC values of infarction lesions have evolution rules with time and space. The evolution rules with time and those in space can be helpful to decide the clinical stage, and to provide the evidence in guiding the treatment or judging the prognosis in infarction.

  6. Correlation of human papillomavirus status with apparent diffusion coefficient of diffusion-weighted MRI in head and neck squamous cell carcinomas.

    Science.gov (United States)

    Driessen, Juliette P; van Bemmel, Alexander J M; van Kempen, Pauline M W; Janssen, Luuk M; Terhaard, Chris H J; Pameijer, Frank A; Willems, Stefan M; Stegeman, Inge; Grolman, Wilko; Philippens, Marielle E P

    2016-04-01

    Identification of prognostic patient characteristics in head and neck squamous cell carcinoma (HNSCC) is of great importance. Human papillomavirus (HPV)-positive HNSCCs have favorable response to (chemo)radiotherapy. Apparent diffusion coefficient, derived from diffusion-weighted MRI, has also shown to predict treatment response. The purpose of this study was to evaluate the correlation between HPV status and apparent diffusion coefficient. Seventy-three patients with histologically proven HNSCC were retrospectively analyzed. Mean pretreatment apparent diffusion coefficient was calculated by delineation of total tumor volume on diffusion-weighted MRI. HPV status was analyzed and correlated to apparent diffusion coefficient. Six HNSCCs were HPV-positive. HPV-positive HNSCC showed significantly lower apparent diffusion coefficient compared to HPV-negative. This correlation was independent of other patient characteristics. In HNSCC, positive HPV status correlates with low mean apparent diffusion coefficient. The favorable prognostic value of low pretreatment apparent diffusion coefficient might be partially attributed to patients with a positive HPV status. © 2015 Wiley Periodicals, Inc. Head Neck 38: E613-E618, 2016. © 2015 Wiley Periodicals, Inc.

  7. On conductivity, permittivity, apparent diffusion coefficient, and their usefulness as cancer markers at MRI frequencies.

    Science.gov (United States)

    Hancu, Ileana; Roberts, Jeannette Christine; Bulumulla, Selaka; Lee, Seung-Kyun

    2015-05-01

    To investigate the permittivity and conductivity of cancerous and normal tissues, their correlation to the apparent diffusion coefficient (ADC), and the specificity that they could add to cancer detection. Breast and prostate carcinomas were induced in rats. Conductivity and permittivity measurements were performed in the anesthetized animals using a dielectric probe and an impedance analyzer between 50 and 270 MHz. The correlations between ADCs (measured at 128 MHz) and conductivity values were investigated. Frequency-dependent discriminant functions were computed to assess the value that each parameter adds to cancer detection. Tumors exhibited higher permittivity than muscle tissue by 27%/12%/5% at 64/128/270MHz. Frequency independent, 15-20% higher conductivity was also noted in tumors compared to muscle tissue over the same frequency range. Strong negative correlation was observed between tissue conductivity and ADC. Whereas permittivity had the strongest discriminatory power at 64 MHz, it became comparable to ADC at 128 MHz and less important than ADC at 270 MHz. Conductivity measurements offered limited advantages in separating cancer from normal tissue beyond what ADC already provided; conversely, permittivity added separation power when added to the discriminant function. The moderately high cancerous tissue permittivity and conductivity impose strong constraints on the capability of MRI-based tissue electrical property measurements. © 2014 Wiley Periodicals, Inc.

  8. Apparent diffusion coefficient of vertebral haemangiomas allows differentiation from malignant focal deposits in whole-body diffusion-weighted MRI

    International Nuclear Information System (INIS)

    Winfield, Jessica M.; Blackledge, Matthew D.; Collins, David J.; Tunariu, Nina; Messiou, Christina; Poillucci, Gabriele; Shah, Vallari; Kaiser, Martin F.

    2018-01-01

    The aim of this study was to identify apparent diffusion coefficient (ADC) values for typical haemangiomas in the spine and to compare them with active malignant focal deposits. This was a retrospective single-institution study. Whole-body magnetic resonance imaging (MRI) scans of 106 successive patients with active multiple myeloma, metastatic prostate or breast cancer were analysed. ADC values of typical vertebral haemangiomas and malignant focal deposits were recorded. The ADC of haemangiomas (72 ROIs, median ADC 1,085 x 10 -6 mm 2 s -1 , interquartile range 927-1,295 x 10 -6 mm 2 s -1 ) was significantly higher than the ADC of malignant focal deposits (97 ROIs, median ADC 682 x 10 -6 mm 2 s -1 , interquartile range 583-781 x 10 -6 mm 2 s -1 ) with a p-value < 10 -6 . Receiver operating characteristic (ROC) analysis produced an area under the curve of 0.93. An ADC threshold of 872 x 10 -6 mm 2 s -1 separated haemangiomas from malignant focal deposits with a sensitivity of 84.7 % and specificity of 91.8 %. ADC values of classical vertebral haemangiomas are significantly higher than malignant focal deposits. The high ADC of vertebral haemangiomas allows them to be distinguished visually and quantitatively from active sites of disease, which show restricted diffusion. (orig.)

  9. Correlation of MRI apparent diffusion coefficient of invasive breast cancer with tumor tissue growth and angiogenesis

    Directory of Open Access Journals (Sweden)

    Ze-Hong Fu

    2017-08-01

    Full Text Available Objective: To study the correlation of MRI apparent diffusion coefficient (ADC value of invasive breast cancer with tumor tissue growth and angiogenesis. Methods: Patients with breast mass who were treated in Wuhan No. 6 Hospital between March 2014 and May 2017 were selected as the research subjects and divided into group A with invasive ductal carcinoma, group B with intraductal carcinoma and group C with benign lesion according to the biopsy results, magnetic resonance diffusion-weighted imaging was conducted to determine ADC values, and biopsy tissue was taken to determine the expression of proliferation genes and angiogenesis genes. Results: USP39, CyclinD1, VEGF, bFGF, Angplt-2, Angplt-3 and Angplt-4 protein expression levels in lesions of group A and group B were significantly higher than those of group C while ADC value as well as ALEX1 and Bax protein expression levels were significantly lower than those of group C; USP39, CyclinD1, VEGF, bFGF, Angplt-2, Angplt-3 and Angplt-4 protein expression levels in lesions of group A were significantly higher than those of group B while ADC value as well as ALEX1 and Bax protein expression levels was significantly lower than those of group B; USP39, CyclinD1, VEGF, bFGF, Angplt-2, Angplt-3 and Angplt-4 protein expression levels in invasive breast cancer tissue with high ADC value were significantly lower than those in invasive breast cancer tissue with low ADC value while ALEX1 and Bax protein expression levels were significantly higher than those in invasive breast cancer tissue with low ADC value. Conclusion: The decrease of ADC value of invasive breast cancer is closely related to cancer cell proliferation and angiogenesis.

  10. The use of MRI apparent diffusion coefficient (ADC) in monitoring the development of brain infarction

    International Nuclear Information System (INIS)

    Shen, Jian-Min; Xia, Xian-Wu; Kang, Wu-Gen; Yuan, Jian-Jun; Sheng, Liang

    2011-01-01

    To study the rules that apparent diffusion coefficient (ADC) changes with time and space in cerebral infarction, and to provide the evidence in defining the infarction stages. 117 work-ups in 98 patients with cerebral infarction (12 hyperacute, 43 acute, 29 subacute, 10 steady, and 23 chronic infarctions) were imaged with both conventional MRI and diffusion weighted imaging. The average ADC values, the relative ADC (rADC) values, and the ADC values or rADC values from the center to the periphery of the lesion were calculated. The average ADC values and the rADC values of hyperacute and acute infarction lesion depressed obviously. rADC values in hyperacute and acute stage was minimized, and increased progressively as time passed and appeared as 'pseudonormal' values in approximately 8 to 14 days. Thereafter, rADC values became greater than normal in chronic stage. There was positive correlation between rADC values and time (P < 0.01). The ADC values and the rADC values in hyperacute and acute lesions had gradient signs that these lesions increased from the center to the periphery. The ADC values and the rADC values in subacute lesions had adverse gradient signs that these lesions decreased from the center to the periphery. The ADC values of infarction lesions have evolution rules with time and space. The evolution rules with time and those in space can be helpful to decide the clinical stage, and to provide the evidence in guiding the treatment or judging the prognosis in infarction

  11. Validity of apparent diffusion coefficient hyperpolarized 3He-MRI using MSCT and pulmonary function tests as references

    DEFF Research Database (Denmark)

    Diaz, Sandra; Casselbrant, Ingrid; Piitulainen, Eeva

    2008-01-01

    PURPOSE: To compare apparent diffusion coefficient (ADC) measurements from hyperpolarized (HP) helium ((3)He)-magnetic resonance imaging (MRI) with quantitative data from multislice Computed Tomography (CT) (MSCT) of the whole lungs and pulmonary function tests (PFT). MATERIALS AND METHODS: Twenty......-seven subjects, 22 with established emphysema and 5 with preclinical emphysema defined by PFT criteria, were examined with HP (3)He-MRI and MSCT. Mean age was 55 (+/-12) years, 18 female and 9 male. Mean ADC from (3)He-MRI was compared with emphysema index (EI), 15th percentile and mean lung density (MLD) values...... from MSCT. Both mean ADC and MSCT data were compared to PFT, especially percent of predicted diffusing capacity of carbon monoxide (%predicted DLCO), using Pearson's correlation test. RESULTS: Mean ADC and standard deviation values were 0.392+/-0.119 cm(2)/s for the established emphysema group and 0...

  12. Diffusion-weighted MRI of epithelial ovarian cancers: Correlation of apparent diffusion coefficient values with histologic grade and surgical stage

    Energy Technology Data Exchange (ETDEWEB)

    Oh, Ji-Won, E-mail: fromentin@naver.com [Department of Radiology, Seoul St. Mary' s Hospital, College of Medicine, The Catholic University of Korea, 222 Banpo-daero, Seocho-gu, Seoul 137-701 (Korea, Republic of); Rha, Sung Eun, E-mail: serha@catholic.ac.kr [Department of Radiology, Seoul St. Mary' s Hospital, College of Medicine, The Catholic University of Korea, 222 Banpo-daero, Seocho-gu, Seoul 137-701 (Korea, Republic of); Oh, Soon Nam, E-mail: hiohsn@catholic.ac.kr [Department of Radiology, Seoul St. Mary' s Hospital, College of Medicine, The Catholic University of Korea, 222 Banpo-daero, Seocho-gu, Seoul 137-701 (Korea, Republic of); Park, Michael Yong, E-mail: digirave@kmle.com [Department of Radiology, Seoul St. Mary' s Hospital, College of Medicine, The Catholic University of Korea, 222 Banpo-daero, Seocho-gu, Seoul 137-701 (Korea, Republic of); Byun, Jae Young, E-mail: jybyun@catholic.ac.kr [Department of Radiology, Seoul St. Mary' s Hospital, College of Medicine, The Catholic University of Korea, 222 Banpo-daero, Seocho-gu, Seoul 137-701 (Korea, Republic of); Lee, Ahwon, E-mail: klee@catholic.ac.kr [Department of Hospital Pathology, Seoul St. Mary' s Hospital, College of Medicine, The Catholic University of Korea, 222 Banpo-daero, Seocho-gu, Seoul 137-701 (Korea, Republic of)

    2015-04-15

    Highlights: •The solid component of all invasive epithelial cancers showed high b{sub 1000} signal intensity. •ADCs can predict the histologic grade of epithelial ovarian cancer. •ADCs correlate negatively to the surgical stage of epithelial ovarian cancer. •ADCs may be useful imaging biomarkers to assess epithelial ovarian cancer. -- Abstract: Objective: The purpose of this article is to correlate the apparent diffusion coefficient (ADC) values of epithelial ovarian cancers with histologic grade and surgical stage. Materials and methods: We enrolled 43 patients with pathologically proven epithelial ovarian cancers for this retrospective study. All patients underwent preoperative pelvic magnetic resonance imaging (MRI) including diffusion-weighted images with b value of 0 and 1000 s/mm{sup 2} at 3.0-T unit. The mean ADC values of the solid portion of the tumor were measured and compared among different histologic grades and surgical stages. Results: The mean ADC values of epithelial ovarian cancers differed significantly between grade 1 (well-differentiated) and grade 2 (moderately-differentiated) (P = 0.013) as well as between grade 1 and grade 3 (poorly-differentiated) (P = 0.01); however, no statistically significant difference existed between grade 2 and grade 3 (P = 0.737). The receiver-operating characteristic analysis indicated that a cutoff ADC value of less than or equal to 1.09 × 10{sup −3} mm{sup 2}/s was associated with 94.4% sensitivity and 85.7% specificity in distinguishing grade 1 and grade 2/3 cancer. The difference in mean ADC values was statistically significant for early stage (FIGO stage I) and advanced stage (FIGO stage II-IV) cancer (P = 0.011). The interobserver agreement for the mean ADC values of epithelial ovarian cancers was excellent. Conclusion: The mean ADC values of the solid portion of epithelial ovarian cancers negatively correlated to histologic grade and surgical stage. The mean ADC values may be useful imaging

  13. Correlation of apparent diffusion coefficient ratio on 3.0 T MRI with prostate cancer Gleason score.

    Science.gov (United States)

    Jyoti, Rajeev; Jain, Tarun Pankaj; Haxhimolla, Hodo; Liddell, Heath; Barrett, Sean Edward

    2018-01-01

    The purpose was to investigate the usefulness of ADC ratio on Diffusion MRI to discriminate between benign and malignant lesions of Prostate. Images of patients who underwent in-gantry MRI guided prostate lesion biopsy were retrospectively analyzed. Prostate Cancers with 20% or more Gleason score (GS) pattern 3 + 3 = 6 in each core or any volume of higher Gleason score pattern were included. ADC ratio was calculated by two reviewers for each lesion. The ADC ratio was calculated for each lesion by dividing the lowest ADC value in a lesion and highest ADC value in normal prostate in peripheral zone (PZ). ADC ratio values were compared with the biopsy result. Data was analysed using independent samples T-test, Spearman correlation, intra-class correlation coefficient (ICC) and Receiver operating characteristic (ROC) curve. 45 lesions in 33 patients were analyzed. 12 lesions were in transitional zone (TZ) and 33 in perpheral zone PZ. All lesions demonstrated an ADC ratio of 0.45 or lower. GS demonstrated a negative correlation with both the ADC value and ADC ratio . However, ADC ratio (p correlation compared to ADC value alone (p = 0.014). There was no significant statistical difference between GS 3 + 4 and GS 4 + 3 mean ADC tumour value (p = 0.167). However when using ADC ratio , there was a significant difference (p = 0.032). ROC curve analysis demonstrated an area under the curve of 0.83 using ADC ratio and 0.76 when using ADC tumour value when discriminating Gleason 6 from Gleason ≥7 tumours. Inter-observer reliability in the calculation of ADC ratios was excellent, with ICC of 0.964. ADC ratio is a reliable and reproducible tool in quantification of diffusion restriction for clinically significant prostate cancer foci.

  14. Analysis of the utility of diffusion-weighted MRI and apparent diffusion coefficient values in distinguishing central nervous system toxoplasmosis from lymphoma

    International Nuclear Information System (INIS)

    Schroeder, Paul C.; Donovan Post, M. Judith; Bruce-Gregorios, Jocelyn; Oschatz, Elizabeth; Stadler, Alfred; Thurnher, Majda M.

    2006-01-01

    Toxoplasmosis and lymphoma are common lesions of the central nervous system in patients with AIDS. It is often difficult to distinguish between these lesions both clinically and radiographically. Previous research has demonstrated restricted diffusion within cerebral lymphomas and bacterial abscesses. However, little work has been done to evaluate the diffusion characteristics of toxoplasmosis lesions. This study was designed to explore further the utility of diffusion-weighted imaging (DWI) and apparent diffusion coefficient (ADC) maps and values in making the distinction between toxoplasmosis and lymphoma. The magnetic resonance imaging (MRI) studies of 36 patients, including 22 with toxoplasmosis (all of whom had AIDS) and 14 with lymphoma (8 of whom had AIDS), at two institutions were reviewed retrospectively. The characteristics of the lesions on DWI were evaluated, and the ADC ratios of the lesions were calculated and compared. There was significant overlap of the ADC ratios of toxoplasma and lymphoma, most notably in the intermediate (1.0-1.6) range. There was variability in ADC ratios even among different lesions in the same patient. In only a minority of the lymphoma patients were the ADC ratios low enough to suggest the correct diagnosis. Our study showed that toxoplasmosis exhibits a wide spectrum of diffusion characteristics with ADC ratios which have significant overlap with those of lymphoma. Therefore, in the majority of patients, ADC ratios are not definitive in making the distinction between toxoplasmosis and lymphoma. (orig.)

  15. Analysis of the utility of diffusion-weighted MRI and apparent diffusion coefficient values in distinguishing central nervous system toxoplasmosis from lymphoma

    Energy Technology Data Exchange (ETDEWEB)

    Schroeder, Paul C.; Donovan Post, M. Judith; Bruce-Gregorios, Jocelyn [University of Miami, Jackson Memorial Hospital, Miami, FL (United States); Oschatz, Elizabeth; Stadler, Alfred; Thurnher, Majda M. [Medical University of Vienna, Department of Radiology Neuroradiology Section, Vienna (Austria)

    2006-10-15

    Toxoplasmosis and lymphoma are common lesions of the central nervous system in patients with AIDS. It is often difficult to distinguish between these lesions both clinically and radiographically. Previous research has demonstrated restricted diffusion within cerebral lymphomas and bacterial abscesses. However, little work has been done to evaluate the diffusion characteristics of toxoplasmosis lesions. This study was designed to explore further the utility of diffusion-weighted imaging (DWI) and apparent diffusion coefficient (ADC) maps and values in making the distinction between toxoplasmosis and lymphoma. The magnetic resonance imaging (MRI) studies of 36 patients, including 22 with toxoplasmosis (all of whom had AIDS) and 14 with lymphoma (8 of whom had AIDS), at two institutions were reviewed retrospectively. The characteristics of the lesions on DWI were evaluated, and the ADC ratios of the lesions were calculated and compared. There was significant overlap of the ADC ratios of toxoplasma and lymphoma, most notably in the intermediate (1.0-1.6) range. There was variability in ADC ratios even among different lesions in the same patient. In only a minority of the lymphoma patients were the ADC ratios low enough to suggest the correct diagnosis. Our study showed that toxoplasmosis exhibits a wide spectrum of diffusion characteristics with ADC ratios which have significant overlap with those of lymphoma. Therefore, in the majority of patients, ADC ratios are not definitive in making the distinction between toxoplasmosis and lymphoma. (orig.)

  16. Assessment of treatment response by total tumor volume and global apparent diffusion coefficient using diffusion-weighted MRI in patients with metastatic bone disease: a feasibility study.

    Directory of Open Access Journals (Sweden)

    Matthew D Blackledge

    Full Text Available We describe our semi-automatic segmentation of whole-body diffusion-weighted MRI (WBDWI using a Markov random field (MRF model to derive tumor total diffusion volume (tDV and associated global apparent diffusion coefficient (gADC; and demonstrate the feasibility of using these indices for assessing tumor burden and response to treatment in patients with bone metastases. WBDWI was performed on eleven patients diagnosed with bone metastases from breast and prostate cancers before and after anti-cancer therapies. Semi-automatic segmentation incorporating a MRF model was performed in all patients below the C4 vertebra by an experienced radiologist with over eight years of clinical experience in body DWI. Changes in tDV and gADC distributions were compared with overall response determined by all imaging, tumor markers and clinical findings at serial follow up. The segmentation technique was possible in all patients although erroneous volumes of interest were generated in one patient because of poor fat suppression in the pelvis, requiring manual correction. Responding patients showed a larger increase in gADC (median change = +0.18, range = -0.07 to +0.78 × 10(-3 mm2/s after treatment compared to non-responding patients (median change = -0.02, range = -0.10 to +0.05 × 10(-3 mm2/s, p = 0.05, Mann-Whitney test, whereas non-responding patients showed a significantly larger increase in tDV (median change = +26%, range = +3 to +284% compared to responding patients (median change = -50%, range = -85 to +27%, p = 0.02, Mann-Whitney test. Semi-automatic segmentation of WBDWI is feasible for metastatic bone disease in this pilot cohort of 11 patients, and could be used to quantify tumor total diffusion volume and median global ADC for assessing response to treatment.

  17. Hyperpolarized 3He apparent diffusion coefficient MRI of the lung: reproducibility and volume dependency in healthy volunteers and patients with emphysema

    DEFF Research Database (Denmark)

    Diaz, S.; Casselbrant, I.; Piitulainen, E.

    2008-01-01

    PURPOSE: To measure the apparent diffusion coefficient (ADC) of hyperpolarized (HP) (3)He gas using diffusion weighted MRI in healthy volunteers and patients with emphysema and examine the reproducibility and volume dependency. MATERIALS AND METHODS: A total of eight healthy volunteers and 16...... patients with emphysema were examined after inhalation of HP (3)He gas mixed with nitrogen (N(2)) during breathhold starting from functional residual capacity (FRC) in supine position. Coronal diffusion-sensitized MR images were acquired. Each subject was imaged on three separate days over a seven...... in mean ADC with increased inhaled gas volume was observed in both groups. CONCLUSION: Mean ADC and SD of HP (3)He MRI is reproducible and discriminates well between healthy controls and patients with emphysema at the higher gas volume. This method is robust and may be useful to gain new insights...

  18. Incidentally detected enhancing lesions found in breast MRI: analysis of apparent diffusion coefficient and T2 signal intensity significantly improves specificity

    Energy Technology Data Exchange (ETDEWEB)

    Arponen, Otso; Masarwah, Amro; Taina, Mikko [Kuopio University Hospital, Kuopio University Hospital, Diagnostic Imaging Centre, Department of Clinical Radiology, PO Box 1777, Kuopio (Finland); Kuopio University Hospital, University of Eastern Finland, Institute of Clinical Medicine, School of Medicine, Department of Clinical Radiology, PO Box 1777, Kuopio (Finland); Sutela, Anna; Koenoenen, Mervi; Hakumaeki, Juhana; Sudah, Mazen [Kuopio University Hospital, Kuopio University Hospital, Diagnostic Imaging Centre, Department of Clinical Radiology, PO Box 1777, Kuopio (Finland); Sironen, Reijo [Kuopio University Hospital, Kuopio University Hospital, Department of Pathology, PO Box 1777, Kuopio (Finland); Kuopio University Hospital, University of Eastern Finland, Institute of Clinical Medicine, School of Medicine, Clinical Pathology and Forensic Medicine, PO Box 1777, Kuopio (Finland); University of Eastern Finland, Cancer Center of Eastern Finland, Kuopio (Finland); Vanninen, Ritva [Kuopio University Hospital, Kuopio University Hospital, Diagnostic Imaging Centre, Department of Clinical Radiology, PO Box 1777, Kuopio (Finland); Kuopio University Hospital, University of Eastern Finland, Institute of Clinical Medicine, School of Medicine, Department of Clinical Radiology, PO Box 1777, Kuopio (Finland); University of Eastern Finland, Cancer Center of Eastern Finland, Kuopio (Finland)

    2016-12-15

    To evaluate the value of adding T2- and diffusion-weighted imaging (DWI) to the BI-RADS registered classification in MRI-detected lesions. This retrospective study included 112 consecutive patients who underwent 3.0T structural breast MRI with T2- and DWI on the basis of EUSOMA recommendations. Morphological and kinetic features, T2 signal intensity (T2 SI) and apparent diffusion coefficient (ADC) findings were assessed. Thirty-three (29.5 %) patients (mean age 57.0 ± 12.7 years) had 36 primarily MRI-detected incidental lesions of which 16 (44.4 %) proved to be malignant. No single morphological or kinetic feature was associated with malignancy. Both low T2 SI (P = 0.009) and low ADC values (≤0.87 x 10{sup -3} mm{sup 2}s{sup -1}, P < 0.001) yielded high specificity (80.0 %/80.0 %). The BI-RADS classification supplemented with information from DWI and T2-WI improved the diagnostic performance of the BI-RADS classification as sensitivity remained 100 % and specificity improved from 30 % to 65.0 %. The numbers of false positive lesions declined from 39 % (N = 14) to 19 % (N = 7). MRI-detected incidental lesions may be challenging to characterize as they have few specific malignancy indicating features. The specificity of MRI can be improved by incorporating T2 SI and ADC values into the BI-RADS assessment. (orig.)

  19. Diagnostic performance of conventional MRI parameters and apparent diffusion coefficient values in differentiating between benign and malignant soft-tissue tumours.

    Science.gov (United States)

    Song, Y; Yoon, Y C; Chong, Y; Seo, S W; Choi, Y-L; Sohn, I; Kim, M-J

    2017-08-01

    To compare the abilities of conventional magnetic resonance imaging (MRI) and apparent diffusion coefficient (ADC) in differentiating between benign and malignant soft-tissue tumours (STT). A total of 123 patients with STT who underwent 3 T MRI, including diffusion-weighted imaging (DWI), were retrospectively analysed using variate conventional MRI parameters, ADC mean and ADC min . For the all-STT group, the correlation between the malignant STT conventional MRI parameters, except deep compartment involvement, compared to those of benign STT were statistically significant with univariate analysis. Maximum diameter of the tumour (p=0.001; odds ratio [OR], 8.97) and ADC mean (p=0.020; OR, 4.30) were independent factors with multivariate analysis. For the non-myxoid non-haemosiderin STT group, signal heterogeneity on axial T1-weighted imaging (T1WI; p=0.017), ADC mean , and ADC min (p=0.001, p=0.001), showed significant differences with univariate analysis between malignancy and benignity. Signal heterogeneity in axial T1WI (p=0.025; OR, 12.64) and ADC mean (p=0.004; OR, 33.15) were independent factors with multivariate analysis. ADC values as well as conventional MRI parameters were useful in differentiating between benign and malignant STT. The ADC mean was the most powerful diagnostic parameter in non-myxoid non-haemosiderin STT. Copyright © 2017 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  20. Validity of apparent diffusion coefficient hyperpolarized 3He-MRI using MSCT and pulmonary function tests as references

    DEFF Research Database (Denmark)

    Diaz, Sandra; Casselbrant, Ingrid; Piitulainen, Eeva

    2008-01-01

    from MSCT. Both mean ADC and MSCT data were compared to PFT, especially percent of predicted diffusing capacity of carbon monoxide (%predicted DLCO), using Pearson's correlation test. RESULTS: Mean ADC and standard deviation values were 0.392+/-0.119 cm(2)/s for the established emphysema group and 0....... Correlations between mean ADC and EI and 15th percentile were both r=0.90 and for MLD r=0.59. There was higher correlation between mean ADC and %predicted DLCO (r=0.90) than between EI and %predicted DLCO (r=0.76). CONCLUSION: HP (3)He-MRI correlates well with density measurements from MSCT and agrees better...

  1. SU-F-303-13: Initial Evaluation of Four Dimensional Diffusion- Weighted MRI (4D-DWI) and Its Effect On Apparent Diffusion Coefficient (ADC) Measurement

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Y [Duke University Medical Physics Program (United States); Yin, F; Czito, B; Bashir, M; Palta, M; Cai, J [Duke University Medical Center, Durham, NC (United States); Zhong, X; Dale, B [Siemens Healthcare, Durham, NC (United States)

    2015-06-15

    Purpose: Diffusion-weighted imaging(DWI) has been shown to have superior tumor-to-tissue contrast for cancer detection.This study aims at developing and evaluating a four dimensional DWI(4D-DWI) technique using retrospective sorting method for imaging respiratory motion for radiotherapy planning,and evaluate its effect on Apparent Diffusion Coefficient(ADC) measurement. Materials/Methods: Image acquisition was performed by repeatedly imaging a volume of interest using a multi-slice single-shot 2D-DWI sequence in the axial planes and cine MRI(served as reference) using FIESTA sequence.Each 2D-DWI image were acquired in xyz-diffusion-directions with a high b-value(b=500s/mm2).The respiratory motion was simultaneously recorded using bellows.Retrospective sorting was applied in each direction to reconstruct 4D-DWI.The technique was evaluated using a computer simulated 4D-digital human phantom(XCAT),a motion phantom and a healthy volunteer under an IRB-approved study.Motion trajectories of regions-of-interests(ROI) were extracted from 4D-DWI and compared with reference.The mean motion trajectory amplitude differences(D) between the two was calculated.To quantitatively analyze the motion artifacts,XCAT were controlled to simulate regular motion and the motions of 10 liver cancer patients.4D-DWI,free-breathing DWI(FB- DWI) were reconstructed.Tumor volume difference(VD) of each phase of 4D-DWI and FB-DWI from the input static tumor were calculated.Furthermore, ADC was measured for each phase of 4D-DWI and FB-DWI data,and mean tumor ADC values(M-ADC) were calculated.Mean M-ADC over all 4D-DWI phases was compared with M-ADC calculated from FB-DWI. Results: 4D-DWI of XCAT,the motion phantom and the healthy volunteer demonstrated the respiratory motion clearly.ROI D values were 1.9mm,1.7mm and 2.0mm,respectively.For motion artifacts analysis,XCAT 4D-DWI images show much less motion artifacts compare to FB-DWI.Mean VD for 4D-WDI and FB-DWI were 8.5±1.4% and 108±15

  2. Correlation between standardized uptake value and apparent diffusion coefficient of neoplastic lesions evaluated with whole-body simultaneous hybrid PET/MRI.

    Science.gov (United States)

    Rakheja, Rajan; Chandarana, Hersh; DeMello, Linda; Jackson, Kimberly; Geppert, Christian; Faul, David; Glielmi, Christopher; Friedman, Kent P

    2013-11-01

    The purpose of this study was to assess the correlation between standardized uptake value (SUV) and apparent diffusion coefficient (ADC) of neoplastic lesions in the use of a simultaneous PET/MRI hybrid system. Twenty-four patients with known primary malignancies underwent FDG PET/CT. They then underwent whole-body PET/MRI. Diffusion-weighted imaging was performed with free breathing and a single-shot spin-echo echo-planar imaging sequence with b values of 0, 350, and 750 s/mm(2). Regions of interest were manually drawn along the contours of neoplastic lesions larger than 1 cm, which were clearly identified on PET and diffusion-weighted images. Maximum SUV (SUVmax) on PET/MRI and PET/CT images, mean SUV (SUVmean), minimum ADC (ADCmin), and mean ADC (ADCmean) were recorded on PET/MR images for each FDG-avid neoplastic soft-tissue lesion with a maximum of three lesions per patient. Pearson correlation coefficient was used to asses the following relations: SUVmax versus ADCmin on PET/MR and PET/CT images, SUVmean versus ADCmean, and ratio of SUVmax to mean liver SUV (SUV ratio) versus ADCmin. A subanalysis of patients with progressive disease versus partial treatment response was performed with the ratio of SUVmax to ADCmin for the most metabolically active lesion. Sixty-nine neoplastic lesions (52 nonosseous lesions, 17 bone metastatic lesions) were evaluated. The mean SUVmax from PET/MRI was 7.0 ± 6.0; SUVmean, 5.6 ± 4.6; mean ADCmin, 1.10 ± 0.58; and mean ADCmean, 1.48 ± 0.72. A significant inverse Pearson correlation coefficient was found between PET/MRI SUVmax and ADCmin (r = -0.21, p = 0.04), between SUVmean and ADCmean (r = -0.18, p = 0.07), and between SUV ratio and ADCmin (r = -0.27, p = 0.01). A similar inverse Pearson correlation coefficient was found between the PET/CT SUVmax and ADCmin. Twenty of 24 patients had previously undergone PET/CT; five patients had a partial treatment response, and six had progressive disease according to Response Evaluation

  3. Diffusion coefficient for anomalous transport

    International Nuclear Information System (INIS)

    1986-01-01

    A report on the progress towards the goal of estimating the diffusion coefficient for anomalous transport is given. The gyrokinetic theory is used to identify different time and length scale inherent to the characteristics of plasmas which exhibit anomalous transport

  4. Haralick texture features from apparent diffusion coefficient (ADC) MRI images depend on imaging and pre-processing parameters.

    Science.gov (United States)

    Brynolfsson, Patrik; Nilsson, David; Torheim, Turid; Asklund, Thomas; Karlsson, Camilla Thellenberg; Trygg, Johan; Nyholm, Tufve; Garpebring, Anders

    2017-06-22

    In recent years, texture analysis of medical images has become increasingly popular in studies investigating diagnosis, classification and treatment response assessment of cancerous disease. Despite numerous applications in oncology and medical imaging in general, there is no consensus regarding texture analysis workflow, or reporting of parameter settings crucial for replication of results. The aim of this study was to assess how sensitive Haralick texture features of apparent diffusion coefficient (ADC) MR images are to changes in five parameters related to image acquisition and pre-processing: noise, resolution, how the ADC map is constructed, the choice of quantization method, and the number of gray levels in the quantized image. We found that noise, resolution, choice of quantization method and the number of gray levels in the quantized images had a significant influence on most texture features, and that the effect size varied between different features. Different methods for constructing the ADC maps did not have an impact on any texture feature. Based on our results, we recommend using images with similar resolutions and noise levels, using one quantization method, and the same number of gray levels in all quantized images, to make meaningful comparisons of texture feature results between different subjects.

  5. Correlation of standardized uptake value and apparent diffusion coefficient in integrated whole-body PET/MRI of primary and recurrent cervical cancer.

    Science.gov (United States)

    Grueneisen, Johannes; Beiderwellen, Karsten; Heusch, Philipp; Buderath, Paul; Aktas, Bahriye; Gratz, Marcel; Forsting, Michael; Lauenstein, Thomas; Ruhlmann, Verena; Umutlu, Lale

    2014-01-01

    To evaluate a potential correlation of the maximum standard uptake value (SUVmax) and the minimum apparent diffusion coefficient (ADCmin) in primary and recurrent cervical cancer based on integrated PET/MRI examinations. 19 consecutive patients (mean age 51.6 years; range 30-72 years) with histopathologically confirmed primary cervical cancer (n = 9) or suspected tumor recurrence (n = 10) were prospectively enrolled for an integrated PET/MRI examination. Two radiologists performed a consensus reading in random order, using a dedicated post-processing software. Polygonal regions of interest (ROI) covering the entire tumor lesions were drawn into PET/MR images to assess SUVmax and into ADC parameter maps to determine ADCmin values. Pearson's correlation coefficients were calculated to assess a potential correlation between the mean values of ADCmin and SUVmax. In 15 out of 19 patients cervical cancer lesions (n = 12) or lymph node metastases (n = 42) were detected. Mean SUVmax (12.5 ± 6.5) and ADCmin (644.5 ± 179.7 × 10(-5) mm2/s) values for all assessed tumor lesions showed a significant but weak inverse correlation (R = -0.342, p correlation between SUVmax and ADCmin (R = -0.692, p correlation. These initial results of this emerging hybrid imaging technique demonstrate the high diagnostic potential of simultaneous PET/MR imaging for the assessment of functional biomarkers, revealing a significant and strong correlation of tumor metabolism and higher cellularity in cervical cancer lesions.

  6. Value of apparent diffusion coefficient (ADC) in evaluating response ...

    African Journals Online (AJOL)

    Objective. To determine whether the apparent diffusion coefficient (ADC) value obtained by diffusion-weighted magnetic resonance imaging (DW-MRI) can be used as a reliable detector of response of carcinoma of the cervix treated with chemoradiotherapy, compared with conventional. T2-weighted MRI. Design.

  7. Apparent diffusion coefficient measurements of bilateral kidneys at 3 T MRI: Effects of age, gender, and laterality in healthy adults

    International Nuclear Information System (INIS)

    Suo, S.-T.; Cao, M.-Q.; Ding, Y.-Z.; Yao, Q.-Y.; Wu, G.-Y.; Xu, J.-R.

    2014-01-01

    Aim: To investigate the effects of age and gender on apparent diffusion coefficient (ADC) measurements of bilateral kidneys at 3 T MRI, and compare the ADC values of left and right kidneys. Materials and methods: In all, 137 healthy participants (mean age 42.8 ± 14.7 years; age range 16–75 years) comprising 68 male and 69 female participants were enrolled. Three Tesla echo-planar diffusion-weighted imaging (DWI) of bilateral kidneys was performed and ADC values were measured in the cortex, medulla, and whole parenchyma. Pearson correlation analysis and linear regression were performed to determine the associations between the ADC values in each region and age. Effects of age and gender on ADC values were analysed using two-factor analysis of variance (ANOVA). The paired-samples t-test was established to compare the ADC values between left and right kidneys. Results: ADC values were significantly higher in the young group (≤50 years) than in the old group (>50 years), and correlated inversely with the age in all regions. Male participants had higher ADC values than female participants in all regions except left medulla. Two-factor ANOVA of age × gender showed no significant interactions between the variables age and gender were found. No significant differences in ADC values between left and right kidneys were observed. Conclusion: Renal ADC values are age- and gender-dependent, and show no significant difference between left and right kidneys. Age- and gender-related effects should be taken into consideration in future renal DWI studies when using normal ADC values from health controls. - Highlights: • Renal apparent diffusion coefficient (ADC) values decrease with ageing. • Men tend to have higher renal ADC values than women. • Bilateral kidneys seem to have no significantly different ADC values

  8. Diffusion, confusion and functional MRI

    International Nuclear Information System (INIS)

    Le Bihan, Denis

    2012-01-01

    Diffusion MRI has been introduced in 1985 and has had a very successful life on its own. While it has become a standard for imaging stroke and white matter disorders, the borders between diffusion MRI and the general field of fMRI have always remained fuzzy. First, diffusion MRI has been used to obtain images of brain function, based on the idea that diffusion MRI could also be made sensitive to blood flow, through the intra-voxel incoherent motion (IVIM) concept. Second, the IVIM concept helped better understand the contribution from different vasculature components to the BOLD fMRI signal. Third, it has been shown recently that a genuine fMRI signal can be obtained with diffusion MRI. This 'DfMRI' signal is notably different from the BOLD fMRI signal, especially for its much faster response to brain activation both at onset and offset, which points out to structural changes in the neural tissues, perhaps such as cell swelling, occurring in activated neural tissue. This short article reviews the major steps which have paved the way for this exciting development, underlying how technical progress with MRI equipment has each time been instrumental to expand the horizon of diffusion MRI toward the field of fMRI. (authors)

  9. Improved differentiation between hepatic hemangioma and metastases on diffusion-weighted MRI by measurement of standard deviation of apparent diffusion coefficient.

    Science.gov (United States)

    Hardie, Andrew D; Egbert, Robert E; Rissing, Michael S

    2015-01-01

    Diffusion-weighted magnetic resonance imaging (DW-MR) can be useful in the differentiation of hemangiomata from liver metastasis, but improved methods other than by mean apparent diffusion coefficient (mADC) are needed. A retrospective review identified 109 metastatic liver lesions and 86 hemangiomata in 128 patients who had undergone DW-MR. For each lesion, mADC and the standard deviation of the mean ADC (sdADC) were recorded and compared by receiver operating characteristic analysis. Mean mADC was higher in benign hemangiomata (1.52±0.12 mm(2)/s) than in liver metastases (1.33±0.18 mm(2)/s), but there was significant overlap in values. The mean sdADC was lower in hemangiomata (101±17 mm(2)/s) than metastases (245±25 mm(2)/s) and demonstrated no overlap in values, which was significantly different (P<.0001). Hemangiomata may be better able to be differentiated from liver metastases on the basis of sdADC than by mADC, although further studies are needed. Copyright © 2015 Elsevier Inc. All rights reserved.

  10. WE-AB-202-12: Voxel-Wise Analysis of Apparent Diffusion Coefficient and Perfusion Maps in Multi-Parametric MRI of Prostate Cancer

    International Nuclear Information System (INIS)

    Engstroem, K; Casares-Magaz, O; Muren, L; Roervik, J; Andersen, E

    2016-01-01

    Purpose: Multi-parametric MRI (mp-MRI) is being introduced in radiotherapy (RT) of prostate cancer, including for tumour delineation in focal boosting strategies. We recently developed an image-based tumour control probability model, based on cell density distributions derived from apparent diffusion coefficient (ADC) maps. Beyond tumour volume and cell densities, tumour hypoxia is also an important determinant of RT response. Since tissue perfusion from mp-MRI has been related to hypoxia we have explored the patterns of ADC and perfusion maps, and the relations between them, inside and outside prostate index lesions. Methods: ADC and perfusion maps from 20 prostate cancer patients were used, with the prostate and index lesion delineated by a dedicated uro-radiologist. To reduce noise, the maps were averaged over a 3×3×3 voxel cube. Associations between different ADC and perfusion histogram parameters within the prostate, inside and outside the index lesion, were evaluated with the Pearson’s correlation coefficient. In the voxel-wise analysis, scatter plots of ADC vs perfusion were analysed for voxels in the prostate, inside and outside of the index lesion, again with the associations quantified with the Pearson’s correlation coefficient. Results: Overall ADC was lower inside the index lesion than in the normal prostate as opposed to ktrans that was higher inside the index lesion than outside. In the histogram analysis, the minimum ktrans was significantly correlated with the maximum ADC (Pearson=0.47; p=0.03). At the voxel level, 15 of the 20 cases had a statistically significant inverse correlation between ADC and perfusion inside the index lesion; ten of the cases had a Pearson < −0.4. Conclusion: The minimum value of ktrans across the tumour was correlated to the maximum ADC. However, on the voxel level, the ‘local’ ktrans in the index lesion is inversely (i.e. negatively) correlated to the ‘local’ ADC in most patients. Research agreement with

  11. Diffusion MRI findings in phenylketonuria

    Energy Technology Data Exchange (ETDEWEB)

    Sener, R.N. [Dept. of Radiology, Ege Univ. Hospital, Izmir (Turkey)

    2003-12-01

    Two patients with phenylketonuria were studied who were under dietary control since infancy, and who were mentally normal. Diffusion MRI was obtained using a spin-echo, echo-planar sequence with a gradient strength of 30 mT/m at 1.5 T. A trace sequence (TR=5700 ms, and TE=139 ms) was used, acquired in 22 s. Heavily diffusion-weighted (b=1000 mm{sup 2}/s) images, and the apparent diffusion coefficient (ADC) values from automatically generated ADC maps were studied. There were two different patterns in these two patients, restricted and increased diffusion patterns. Restricted diffusion pattern consisted of high-signal on b=1000 s/mm{sup 2} images with low ADC values ranging from 0.46 to 0.57 x 10{sup -3} mm{sup 2}/s. Increased diffusion pattern consisted of normal b=1000 s/mm{sup 2} images with high ADC values ranging from 1.37 to 1.63 x 10{sup -3} mm{sup 2}/s. It is likely that these values reflected presence of two different histopathological changes in phenylketonuria or reflected different stages of the same disease. (orig.)

  12. Diffusion MRI findings in phenylketonuria

    International Nuclear Information System (INIS)

    Sener, R.N.

    2003-01-01

    Two patients with phenylketonuria were studied who were under dietary control since infancy, and who were mentally normal. Diffusion MRI was obtained using a spin-echo, echo-planar sequence with a gradient strength of 30 mT/m at 1.5 T. A trace sequence (TR=5700 ms, and TE=139 ms) was used, acquired in 22 s. Heavily diffusion-weighted (b=1000 mm 2 /s) images, and the apparent diffusion coefficient (ADC) values from automatically generated ADC maps were studied. There were two different patterns in these two patients, restricted and increased diffusion patterns. Restricted diffusion pattern consisted of high-signal on b=1000 s/mm 2 images with low ADC values ranging from 0.46 to 0.57 x 10 -3 mm 2 /s. Increased diffusion pattern consisted of normal b=1000 s/mm 2 images with high ADC values ranging from 1.37 to 1.63 x 10 -3 mm 2 /s. It is likely that these values reflected presence of two different histopathological changes in phenylketonuria or reflected different stages of the same disease. (orig.)

  13. Form of multicomponent Fickian diffusion coefficients matrix

    International Nuclear Information System (INIS)

    Wambui Mutoru, J.; Firoozabadi, Abbas

    2011-01-01

    Highlights: → Irreversible thermodynamics establishes form of multicomponent diffusion coefficients. → Phenomenological coefficients and thermodynamic factors affect sign of diffusion coefficients. → Negative diagonal elements of diffusion coefficients matrix can occur in non-ideal mixtures. → Eigenvalues of the matrix of Fickian diffusion coefficients may not be all real. - Abstract: The form of multicomponent Fickian diffusion coefficients matrix in thermodynamically stable mixtures is established based on the form of phenomenological coefficients and thermodynamic factors. While phenomenological coefficients form a symmetric positive definite matrix, the determinant of thermodynamic factors matrix is positive. As a result, the Fickian diffusion coefficients matrix has a positive determinant, but its elements - including diagonal elements - can be negative. Comprehensive survey of reported diffusion coefficients data for ternary and quaternary mixtures, confirms that invariably the determinant of the Fickian diffusion coefficients matrix is positive.

  14. Less Confusion in Diffusion MRI

    NARCIS (Netherlands)

    Tax, CMW

    2016-01-01

    With its unique ability to investigate tissue architecture and microstructure in vivo, diffusion MRI (dMRI) has gained tremendous interest and the society has been continuously triggered to develop novel dMRI image analysis approaches. With the overwhelming amount of strategies currently available

  15. Pre-treatment MRI minimum apparent diffusion coefficient value is a potential prognostic imaging biomarker in cervical cancer patients treated with definitive chemoradiation

    International Nuclear Information System (INIS)

    Marconi, Daniel Grossi; Fregnani, Jose Humberto Tavares Guerreiro; Rossini, Rodrigo Ribeiro; Netto, Ana Karina Borges Junqueira; Lucchesi, Fabiano Rubião; Tsunoda, Audrey Tieko; Kamrava, Mitchell

    2016-01-01

    Diffusion Weighted (DW) Magnetic Resonance Imaging (MRI) has been studed in several cancers including cervical cancer. This study was designed to investigate the association of DW-MRI parameters with baseline clinical features and clinical outcomes (local regional control (LRC), disease free survival (DFS) and disease specific survival (DSS)) in cervical cancer patients treated with definitive chemoradiation. This was a retrospective study approved by an institutional review board that included 66 women with cervical cancer treated with definitive chemoradiation who underwent pre-treatment MRI at our institution between 2012 and 2013. A region of interest (ROI) was manually drawn by one of three radiologists with experience in pelvic imaging on a single axial CT slice encompassing the widest diameter of the cervical tumor while excluding areas of necrosis. The following apparent diffusion coefficient (ADC) values (×10 −3 mm 2 /s) were extracted for each ROI: Minimum - ADC min , Maximum - ADC max , Mean - ADC mean , and Standard Deviation of the ADC - ADC dev . Receiver operating characteristic (ROC) curves were built to choose the most accurate cut off value for each ADC value. Correlation between imaging metrics and baseline clinical features were evaluated using the Mann Whitney test. Confirmatory multi-variate Cox modeling was used to test associations with LRC (adjusted by gross tumor volume – GTV), DFS and DSS (both adjusted by FIGO stage). Kaplan Meyer curves were built for DFS and DSS. A p-value < 0.05 was considered significant. Women median age was 52 years (range 23–90). 67 % had FIGO stage I-II disease while 33 % had FIGO stage III-IV disease. Eighty-two percent had squamous cell cancer. Eighty-eight percent received concurrent cisplatin chemotherapy with radiation. Median EQD2 of external beam and brachytherapy was 82.2 Gy (range 74–84). Women with disease staged III-IV (FIGO) had significantly higher mean ADC max values compared with those

  16. Computational Diffusion MRI : MICCAI Workshop

    CERN Document Server

    Grussu, Francesco; Ning, Lipeng; Tax, Chantal; Veraart, Jelle

    2018-01-01

    This volume presents the latest developments in the highly active and rapidly growing field of diffusion MRI. The reader will find numerous contributions covering a broad range of topics, from the mathematical foundations of the diffusion process and signal generation, to new computational methods and estimation techniques for the in-vivo recovery of microstructural and connectivity features, as well as frontline applications in neuroscience research and clinical practice. These proceedings contain the papers presented at the 2017 MICCAI Workshop on Computational Diffusion MRI (CDMRI’17) held in Québec, Canada on September 10, 2017, sharing new perspectives on the most recent research challenges for those currently working in the field, but also offering a valuable starting point for anyone interested in learning computational techniques in diffusion MRI. This book includes rigorous mathematical derivations, a large number of rich, full-colour visualisations and clinically relevant results. As such, it wil...

  17. Clinical relevance of the apparent diffusion coefficient value of metastatic bone tumours on diffusion-weighted MRI images: differences according to the types of primary tumour, the affected bones, and clinical factors.

    Science.gov (United States)

    Cha, M J; Yoon, Y C

    2015-10-01

    To evaluate whether the apparent diffusion coefficient (ADC) of metastatic bone tumours on diffusion-weighted magnetic resonance imaging (MRI) images differs according to the type of primary cancer, the affected bone, and clinical factors. For this retrospective study, two radiologists reviewed MRI images, including ADC maps, of 67 patients (M:F=38:29; median age, 48 years) who were diagnosed with bone metastasis by means of histological or clinical confirmation. The primary tumours included 29 lung adenocarcinomas, 15 invasive ductal adenocarcinomas of the breast, 13 hepatocellular carcinomas, six prostatic carcinomas, and four renal cell carcinomas. ADC values of the metastatic tumour were compared according to the type of primary malignancy, the affected bone, and the age and sex of the patient using Kruskal-Wallis and Mann-Whitney U-tests with Bonferroni correction. In addition, pre-contrast CT images were available in 38 of 67 patients; a subanalysis of the CT radiodensity and ADC values were performed with Spearman correlation. The mean, standard deviation, and minimum and maximum values of the ADC of metastatic bone tumours did not differ significantly according to type of primary malignancy, the affected bone, or clinical variables (p>0.1). The ADC value was not significantly correlated with CT radiodensity (p=0.24). Intra- and interobserver agreements for the mean ADC values were excellent (intra-observer: p=0.98; interobserver: p=0.98). Assessment of the ADC value of metastatic bone tumours is not reliable for differentiation of the type of primary cancer. Copyright © 2015 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  18. New definition of the cell diffusion coefficient

    International Nuclear Information System (INIS)

    Koehler, P.

    1975-01-01

    As was shown in a recent work by Gelbard, the usually applied Benoist definition of the cell diffusion coefficient gives two different values if two different definitions of the cell are made. A new definition is proposed that preserves the neutron balance for the homogenized lattice and that is independent of the cell definition. The resulting diffusion coefficient is identical with the main term of Benoist's diffusion coefficient

  19. The Spatial Relationship between Apparent Diffusion Coefficient and Standardized Uptake Value of 18F-Fluorodeoxyglucose Has a Crucial Influence on the Numeric Correlation of Both Parameters in PET/MRI of Lung Tumors.

    Science.gov (United States)

    Sauter, Alexander W; Stieltjes, Bram; Weikert, Thomas; Gatidis, Sergios; Wiese, Mark; Klarhöfer, Markus; Wild, Damian; Lardinois, Didier; Bremerich, Jens; Sommer, Gregor

    2017-01-01

    The minimum apparent diffusion coefficient (ADC min ) derived from diffusion-weighted MRI (DW-MRI) and the maximum standardized uptake value (SUV max ) of FDG-PET are markers of aggressiveness in lung cancer. The numeric correlation of the two parameters has been extensively studied, but their spatial interplay is not well understood. After FDG-PET and DW-MRI coregistration, values and location of ADC min - and SUV max -voxels were analyzed. The upper limit of the 95% confidence interval for registration accuracy of sequential PET/MRI was 12 mm, and the mean distance ( D ) between ADC min - and SUV max -voxels was 14.0 mm (average of two readers). Spatial mismatch ( D > 12 mm) between ADC min and SUV max was found in 9/25 patients. A considerable number of mismatch cases (65%) was also seen in a control group that underwent simultaneous PET/MRI. In the entire patient cohort, no statistically significant correlation between SUV max and ADC min was seen, while a moderate negative linear relationship ( r = -0.5) between SUV max and ADC min was observed in tumors with a spatial match ( D ≤ 12 mm). In conclusion, spatial mismatch between ADC min and SUV max is found in a considerable percentage of patients. The spatial connection of the two parameters SUV max and ADC min has a crucial influence on their numeric correlation.

  20. Predicting and monitoring response to chemotherapy by 1,3-bis(2-chloroethyl)-1-nitrosourea in subcutaneously implanted 9L glioma using the apparent diffusion coefficient of water and 23Na MRI.

    Science.gov (United States)

    Babsky, Andriy M; Hekmatyar, S K; Zhang, Hong; Solomon, James L; Bansal, Navin

    2006-07-01

    To examine the effects of the alkylating anticancer drug 1,3-bis(2-chloroethyl)-1-nitrosourea (BCNU) on (23)Na MRI and the water apparent diffusion coefficient (ADC) in subcutaneously- (sc-) implanted 9L glioma in rats. (23)Na MRI and (1)H water ADC measurements were performed on sham-treated control (N = 6) and BCNU-treated (N = 15) Fisher rats one day before BCNU injection and then one, three, and five days after BCNU injection. The BCNU-treated tumors were divided into BCNU-responsive (R(BCNU)) and BCNU-nonresponsive (NR(BCNU)) groups depending on the tumor volume changes that occurred after therapy. The pretreatment (23)Na MRI signal intensity (SI) and water ADC values were higher in R(BCNU) tumors compared to NR(BCNU) tumors. (23)Na MRI SI and water ADC increased with tumor growth in control and NR(BCNU) groups, but these changes were interrupted by BCNU therapy in R(BCNU) group. (23)Na MRI and water ADC measurements may be useful for predicting and monitoring response to chemotherapy in some tumors. However, the changes that occurred in (23)Na MRI SI and water ADC in sc-implanted 9L tumors are in contrast to previously published results for BCNU therapy of orthotopic 9L tumors. This may have important implications for monitoring therapy response in tumors. (c) 2006 Wiley-Liss, Inc.

  1. Dynamics of cerebral edema and the apparent diffusion coefficient of water changes in patients with severe traumatic brain injury. A prospective MRI study

    International Nuclear Information System (INIS)

    Pasco, Anne; Minassian, Aram Ter; Chapon, Catherine; Lemaire, Laurent; Benoit, Jean-Pierre; Jeune, Jean-Jacques Le; Franconi, Florence; Darabi, Dana; Caron, Christine

    2006-01-01

    The distinction between intracellular (ICE) and extracellular edema (ECE) has a crucial prognostic and therapeutic importance in patients with severe traumatic brain injury (STBI). Indeed, ICE usually leads to cellular death, and maintenance of a cerebral perfusion pressure (CPP) above 70 mmHg is still under debate since this practice may increase ECE. The purpose of this study was to describe the ECE and ICE kinetics associated with STBI using quantitative diffusion MRI. Twelve patients were prospectively studied. The initial ADC in ICE measured on day 1.3±0.7 is significantly reduced compared to normal-appearing parenchyma (0.51±0.12 * 10 -3 mm 2 /s vs. 0.76±0.03 * 10 -3 mm 2 /s, n=12, P MRI2 =0.40±0.11 * 10 -3 mm 2 /s), ADC values in the extension area at the first MRI were slightly, but not significantly reduced compared to normal parenchyma (0.69±0.05 * 10 -3 mm 2 /s, P=0.29). Normalization occurred equally by day 14. ADC in ECE (1.34±0.22 * 10 -3 mm 2 /s) was elevated and stable with time under CPP therapy. Therefore, ECE is not worsened by CCP therapy, and ICE appears more relevant than ECE in STBI. (orig.)

  2. Diffusion coefficients of paracetamol in aqueous solutions

    International Nuclear Information System (INIS)

    Ribeiro, Ana C.F.; Barros, Marisa C.F.; Veríssimo, Luís M.P.; Santos, Cecilia I.A.V.; Cabral, Ana M.T.D.P.V.; Gaspar, Gualter D.; Esteso, Miguel A.

    2012-01-01

    Highlights: ► Mutual diffusion coefficients of paracetamol in aqueous dilute solutions. ► Influence of the thermodynamic factors on the variation of their mutual diffusion coefficients. ► Estimation of the mutual limiting diffusion coefficients of the molecular, D m 0 , and ionized forms, D ± 0 , of this drug. - Abstract: Binary mutual diffusion coefficients measured by the Taylor dispersion method, for aqueous solutions of paracetamol (PA) at concentrations from (0.001 to 0.050) mol·dm −3 at T = 298.15 K, are reported. From the Nernst–Hartley equation and our experimental results, the limiting diffusion coefficient of this drug and its thermodynamic factors are estimated, thereby contributing in this way to a better understanding of the structure of such systems and of their thermodynamic behaviour in aqueous solution at different concentrations.

  3. Diffusion weighted MRI and 18F-FDG PET/CT in non-small cell lung cancer (NSCLC): Does the apparent diffusion coefficient (ADC) correlate with tracer uptake (SUV)?

    International Nuclear Information System (INIS)

    Regier, M.; Derlin, T.; Schwarz, D.; Laqmani, A.; Henes, F.O.; Groth, M.; Buhk, J.-H.; Kooijman, H.; Adam, G.

    2012-01-01

    Introduction: To investigate the potential correlation of the apparent diffusion coefficient assessed by diffusion-weighted MRI (DWI) and glucose metabolism determined by the standardized uptake value (SUV) at 18F-FDG PET/CT in non-small cell lung cancer (NSCLC). Materials and methods: 18F-FDG PET/CT and DWI (TR/TE, 2000/66 ms; b-values, 0 and 500 s/mm 2 ) were performed in 41 consecutive patients with histologically verified NSCLC. Analysing the PET-CT data calculation of the mean (SUV mean ) and maximum (SUV max ) SUV was performed. By placing a region-of-interest (ROI) encovering the entire tumor mean (ADC mean ) and minimum ADC (ADC min ) were determined by two independent radiologists. Results of 18F-FDG PET-CT and DWI were compared on a per-patient basis. For statistical analysis Pearson's correlation coefficient, Bland–Altman and regression analysis were assessed. Results: Data analysis revealed a significant inverse correlation of the ADC min and SUV max (r = −0.46; p = 0.032). Testing the correlation of the ADC min and SUV max for each histological subtype separately revealed that the inverse correlation was good for both adenocarcinomas (r = −0.47; p = 0.03) and squamouscell carcinomas (r = −0.71; p = 0.002), respectively. No significant correlation was found for the comparison of ADC min and SUV mean (r = −0.29; p = 0.27), ADC mean vs. SUV mean (r = −0.28; p = 0.31) or ADC mean vs. SUV max (r = −0.33; p = 0.23). The κ-value of 0.88 indicated a good agreement between both observers. Conclusion: This preliminary study is the first to verify the relation between the SUV and the ADC in NSCLC. The significant inverse correlation of these two quantitative imaging approaches points out the association of metabolic activity and tumor cellularity. Therefore, DWI with ADC measurement might represent a new prognostic marker in NSCLC

  4. Diffusion-weighted MRI of the prostate

    International Nuclear Information System (INIS)

    Mueller-Lisse, U.G.; Scherr, M.K.; Mueller-Lisse, U.L.; Zamecnik, P.; Schlemmer, H.P.W.

    2011-01-01

    Diffusion-weighted magnetic resonance imaging (DWI) can complement MRI of the prostate in the detection and localization of prostate cancer, particularly after previous negative biopsy. A total of 13 original reports and 2 reviews published in 2010 demonstrate that prostate cancer can be detected by DWI due to its increased cell density and decreased diffusiveness, either qualitatively in DWI images or quantitatively by means of the apparent diffusion coefficient (ADC). In the prostate, the ADC is influenced by the strength of diffusion weighting, localization (peripheral or transitional zone), presence of prostatitis or hemorrhage and density and differentiation of prostate cancer cells. Mean differences between healthy tissue of the peripheral zone and prostate cancer appear to be smaller for ADC than for the (choline + creatine)/citrate ratio in MR spectroscopy. Test quality parameters vary greatly between different studies but appear to be slightly better for combined MRI and DWI than for MRI of the prostate alone. Clinical validation of DWI of the prostate requires both increased technical conformity and increased numbers of patients in clinical studies. (orig.) [de

  5. Diffusion Coefficients of Several Aqueous Alkanolamine Solutions

    NARCIS (Netherlands)

    Snijder, Erwin D.; Riele, Marcel J.M. te; Versteeg, Geert F.; Swaaij, W.P.M. van

    1993-01-01

    The Taylor dispersion technique was applied for the determination of diffusion coefficients of various systems. Experiments with the system KCl in water showed that the experimental setup provides accurate data. For the alkanolamines monoethanolamine (MEA), diethanolamine (DEA), methyldiethanolamine

  6. Correlation of 18F-FDG PET and MRI Apparent Diffusion Coefficient Histogram Metrics with Survival in Diffuse Intrinsic Pontine Glioma: A Report from the Pediatric Brain Tumor Consortium.

    Science.gov (United States)

    Zukotynski, Katherine A; Vajapeyam, Sridhar; Fahey, Frederic H; Kocak, Mehmet; Brown, Douglas; Ricci, Kelsey I; Onar-Thomas, Arzu; Fouladi, Maryam; Poussaint, Tina Young

    2017-08-01

    The purpose of this study was to describe baseline 18 F-FDG PET voxel characteristics in pediatric diffuse intrinsic pontine glioma (DIPG) and to correlate these metrics with baseline MRI apparent diffusion coefficient (ADC) histogram metrics, progression-free survival (PFS), and overall survival. Methods: Baseline brain 18 F-FDG PET and MRI scans were obtained in 33 children from Pediatric Brain Tumor Consortium clinical DIPG trials. 18 F-FDG PET images, postgadolinium MR images, and ADC MR images were registered to baseline fluid attenuation inversion recovery MR images. Three-dimensional regions of interest on fluid attenuation inversion recovery MR images and postgadolinium MR images and 18 F-FDG PET and MR ADC histograms were generated. Metrics evaluated included peak number, skewness, and kurtosis. Correlation between PET and MR ADC histogram metrics was evaluated. PET pixel values within the region of interest for each tumor were plotted against MR ADC values. The association of these imaging markers with survival was described. Results: PET histograms were almost always unimodal (94%, vs. 6% bimodal). None of the PET histogram parameters (skewness or kurtosis) had a significant association with PFS, although a higher PET postgadolinium skewness tended toward a less favorable PFS (hazard ratio, 3.48; 95% confidence interval [CI], 0.75-16.28 [ P = 0.11]). There was a significant association between higher MR ADC postgadolinium skewness and shorter PFS (hazard ratio, 2.56; 95% CI, 1.11-5.91 [ P = 0.028]), and there was the suggestion that this also led to shorter overall survival (hazard ratio, 2.18; 95% CI, 0.95-5.04 [ P = 0.067]). Higher MR ADC postgadolinium kurtosis tended toward shorter PFS (hazard ratio, 1.30; 95% CI, 0.98-1.74 [ P = 0.073]). PET and MR ADC pixel values were negatively correlated using the Pearson correlation coefficient. Further, the level of PET and MR ADC correlation was significantly positively associated with PFS; tumors with higher

  7. Molecular Diffusion Coefficients: Experimental Determination and Demonstration.

    Science.gov (United States)

    Fate, Gwendolyn; Lynn, David G.

    1990-01-01

    Presented are laboratory methods which allow the demonstration and determination of the diffusion coefficients of compounds ranging in size from water to small proteins. Included are the procedures involving the use of a spectrometer, UV cell, triterated agar, and oxygen diffusion. Results including quantification are described. (CW)

  8. Problems with Discontinuous Diffusion/Dispersion Coefficients

    Directory of Open Access Journals (Sweden)

    Stefano Ferraris

    2012-01-01

    accurate on smooth solutions and based on a special numerical treatment of the diffusion/dispersion coefficients that makes its application possible also when such coefficients are discontinuous. Numerical experiments confirm the convergence of the numerical approximation and show a good behavior on a set of benchmark problems in two space dimensions.

  9. Effects of gender, age, and body mass index on fat contents and apparent diffusion coefficients in healthy parotid glands: an MRI evaluation

    International Nuclear Information System (INIS)

    Chang, Hing-Chiu; Juan, Chun-Jung; Hsu, Hsian-He; Chiu, Hui-Chu; Cheng, Cheng-Chieh; Chiu, Su-Chin; Liu, Yi-Jui; Chung, Hsiao-Wen

    2014-01-01

    To establish standard apparent diffusion coefficient (ADC) and the fat content as a function of age, gender and body mass index (BMI) in healthy parotid glands, and to address the influences of fat suppression on ADC measurements. A total of 100 healthy adults (gender and age evenly distributed) were prospectively recruited, with parotid fat content measured from gradient-echo images with fat-water separated using iterative decomposition with echo asymmetry and least squares (IDEAL). The ADCs were estimated using both fat-saturated and non-fat-saturated diffusion-weighted imaging via a periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER) technique. Parotid fat content was larger in men than in women by about 10 percentage points (P < 0.005), and positively associated with BMI and age for both genders (mostly with P < 0.001). ADCs estimated with non-fat-saturated PROPELLER were significantly lower in men than in women (P < 0.005), but showed no gender difference if measured using fat-saturated PROPELLER (P = 0.840). The negative association between parotid ADC and age/BMI/fat (P < 0.001) showed greater regression slopes in non-fat-saturated PROPELLER than in fat-saturated data. Parotid fat content in healthy adults correlates positively with both age and BMI; the correlation with age is gender-dependent. Parotid ADC measurements are strongly influenced by fat saturation. (orig.)

  10. Utility of histogram analysis of apparent diffusion coefficient maps obtained using 3.0T MRI for distinguishing uterine carcinosarcoma from endometrial carcinoma.

    Science.gov (United States)

    Takahashi, Masahiro; Kozawa, Eito; Tanisaka, Megumi; Hasegawa, Kousei; Yasuda, Masanori; Sakai, Fumikazu

    2016-06-01

    We explored the role of histogram analysis of apparent diffusion coefficient (ADC) maps for discriminating uterine carcinosarcoma and endometrial carcinoma. We retrospectively evaluated findings in 13 patients with uterine carcinosarcoma and 50 patients with endometrial carcinoma who underwent diffusion-weighted imaging (b = 0, 500, 1000 s/mm(2) ) at 3T with acquisition of corresponding ADC maps. We derived histogram data from regions of interest drawn on all slices of the ADC maps in which tumor was visualized, excluding areas of necrosis and hemorrhage in the tumor. We used the Mann-Whitney test to evaluate the capacity of histogram parameters (mean ADC value, 5th to 95th percentiles, skewness, kurtosis) to discriminate uterine carcinosarcoma and endometrial carcinoma and analyzed the receiver operating characteristic (ROC) curve to determine the optimum threshold value for each parameter and its corresponding sensitivity and specificity. Carcinosarcomas demonstrated significantly higher mean vales of ADC, 95th, 90th, 75th, 50th, 25th percentiles and kurtosis than endometrial carcinomas (P Histogram analysis of ADC maps might be helpful for discriminating uterine carcinosarcomas and endometrial carcinomas. J. Magn. Reson. Imaging 2016;43:1301-1307. © 2015 Wiley Periodicals, Inc.

  11. Effects of gender, age, and body mass index on fat contents and apparent diffusion coefficients in healthy parotid glands: an MRI evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Hing-Chiu [National Taiwan University, Graduate Institute of Biomedical Electronics and Bioinformatics, Taipei (China); Duke University Medical Center, Brain Imaging and Analysis Center, Durham, NC (United States); GE Healthcare, Applied Science Laboratory, Taipei (China); Juan, Chun-Jung; Hsu, Hsian-He [National Defense Medical Center, Department of Radiology, Taipei (China); Tri-Service General Hospital, Department of Radiology, Taipei (China); Chiu, Hui-Chu [Tatung University, Graduate Institute of Design Science, Taipei (China); Cheng, Cheng-Chieh; Chiu, Su-Chin [National Taiwan University, Graduate Institute of Biomedical Electronics and Bioinformatics, Taipei (China); Liu, Yi-Jui [Feng Chia University, Department of Automatic Control Engineering, Taichung (China); Chung, Hsiao-Wen [National Taiwan University, Graduate Institute of Biomedical Electronics and Bioinformatics, Taipei (China); Tri-Service General Hospital, Department of Radiology, Taipei (China); National Taiwan University, MD.624, Department of Electrical Engineering, Taipei (China)

    2014-09-15

    To establish standard apparent diffusion coefficient (ADC) and the fat content as a function of age, gender and body mass index (BMI) in healthy parotid glands, and to address the influences of fat suppression on ADC measurements. A total of 100 healthy adults (gender and age evenly distributed) were prospectively recruited, with parotid fat content measured from gradient-echo images with fat-water separated using iterative decomposition with echo asymmetry and least squares (IDEAL). The ADCs were estimated using both fat-saturated and non-fat-saturated diffusion-weighted imaging via a periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER) technique. Parotid fat content was larger in men than in women by about 10 percentage points (P < 0.005), and positively associated with BMI and age for both genders (mostly with P < 0.001). ADCs estimated with non-fat-saturated PROPELLER were significantly lower in men than in women (P < 0.005), but showed no gender difference if measured using fat-saturated PROPELLER (P = 0.840). The negative association between parotid ADC and age/BMI/fat (P < 0.001) showed greater regression slopes in non-fat-saturated PROPELLER than in fat-saturated data. Parotid fat content in healthy adults correlates positively with both age and BMI; the correlation with age is gender-dependent. Parotid ADC measurements are strongly influenced by fat saturation. (orig.)

  12. Diffusion and transport coefficients in synthetic opals

    International Nuclear Information System (INIS)

    Sofo, J. O.; Mahan, G. D.

    2000-01-01

    Opals are structures composed of close-packed spheres in the size range of nano to micrometers. They are sintered to create small necks at the points of contact. We have solved the diffusion problem in such structures. The relation between the diffusion coefficient and the thermal and electrical conductivity is used to estimate the transport coefficients of opal structures as a function of the neck size and the mean free path of the carriers. The theory presented is also applicable to the diffusion problem in other periodic structures. (c) 2000 The American Physical Society

  13. Correlation and prediction of gaseous diffusion coefficients.

    Science.gov (United States)

    Marrero, T. R.; Mason, E. A.

    1973-01-01

    A new correlation method for binary gaseous diffusion coefficients from very low temperatures to 10,000 K is proposed based on an extended principle of corresponding states, and having greater range and accuracy than previous correlations. There are two correlation parameters that are related to other physical quantities and that are predictable in the absence of diffusion measurements. Quantum effects and composition dependence are included, but high-pressure effects are not. The results are directly applicable to multicomponent mixtures.

  14. Lattice cell diffusion coefficients. Definitions and comparisons

    International Nuclear Information System (INIS)

    Hughes, R.P.

    1980-01-01

    Definitions of equivalent diffusion coefficients for regular lattices of heterogeneous cells have been given by several authors. The paper begins by reviewing these different definitions and the unification of their derivation. This unification makes clear how accurately each definition (together with appropriate cross-section definitions to preserve the eigenvalue) represents the individual reaction rates within the cell. The approach can be extended to include asymmetric cells and whereas before, the buckling describing the macroscopic flux shape was real, here it is found to be complex. A neutron ''drift'' coefficient as well as a diffusion coefficient is necessary to produce the macroscopic flux shape. The numerical calculation of the various different diffusion coefficients requires the solutions of equations similar to the ordinary transport equation for an infinite lattice. Traditional reactor physics codes are not sufficiently flexible to solve these equations in general. However, calculations in certain simple cases are presented and the theoretical results quantified. In difficult geometries, Monte Carlo techniques can be used to calculate an effective diffusion coefficient. These methods relate to those already described provided that correlation effects between different generations of neutrons are included. Again, these effects are quantified in certain simple cases. (author)

  15. Combining standardized uptake value of FDG-PET and apparent diffusion coefficient of DW-MRI improves risk stratification in head and neck squamous cell carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Preda, Lorenzo; Summers, Paul E. [European Institute of Oncology, Department of Radiology, Milan (Italy); Conte, Giorgio; Bonello, Luke; Giannitto, Caterina; Ruju, Francesca [University of Milan, Specialisation School of Radiology, Milan (Italy); Travaini, Laura L.; Grana, Chiara [European Institute of Oncology, Department of Nuclear Medicine, Milan (Italy); Raimondi, Sara [European Institute of Oncology, Department of Epidemiology and Biostatistics, Milan (Italy); Mohssen, Ansarin [European Institute of Oncology, Department of Head and Neck Surgery, Milan (Italy); Alterio, Daniela [European Institute of Oncology, Department of Radiotherapy, Milan (Italy); Cossu Rocca, Maria [European Institute of Oncology, Department of Urogenital Cancer Medical Treatment, Milan (Italy); Bellomi, Massimo [European Institute of Oncology, Department of Radiology, Milan (Italy); University of Milan, Department of Oncology and Haematology-Oncology, Milan (Italy)

    2016-12-15

    To assess the independent prognostic value of standardized uptake value (SUV) and apparent diffusion coefficient (ADC), separately and combined, in order to evaluate if the combination of these two variables allows further prognostic stratification of patients with head and neck squamous cell carcinomas (HNSCC). Pretreatment SUV and ADC were calculated in 57 patients with HNSCC. Mean follow-up was 21.3 months. Semiquantitative analysis of primary tumours was performed using SUV{sub maxT/B}, ADC{sub mean}, ADC{sub min} and ADC{sub max}. The prognostic value of SUV{sub maxT/B}, ADC{sub mean}, ADC{sub min} and ADC{sub max} in predicting disease-free survival (DFS) was evaluated with log-rank test and Cox regression models. Patients with SUV{sub maxT/B} ≥5.75 had an overall worse prognosis (p = 0.003). After adjusting for lymph node status and diameter, SUV{sub maxT/B} and ADC{sub min} were both significant predictors of DFS with hazard ratio (HR) = 10.37 (95 % CI 1.22-87.95) and 3.26 (95 % CI 1.20-8.85) for SUV{sub maxT/B} ≥5.75 and ADC{sub min} ≥0.58 x 10{sup -3} mm{sup 2}/s, respectively. When the analysis was restricted to subjects with SUV{sub maxT/B} ≥5.75, high ADC{sub min} significantly predicted a worse prognosis, with adjusted HR = 3.11 (95 % CI 1.13-8.55). The combination of SUV{sub maxT/B} and ADC{sub min} improves the prognostic role of the two separate parameters; patients with high SUV{sub maxT/B} and high ADC{sub min} are associated with a poor prognosis. (orig.)

  16. Combining standardized uptake value of FDG-PET and apparent diffusion coefficient of DW-MRI improves risk stratification in head and neck squamous cell carcinoma.

    Science.gov (United States)

    Preda, Lorenzo; Conte, Giorgio; Bonello, Luke; Giannitto, Caterina; Travaini, Laura L; Raimondi, Sara; Summers, Paul E; Mohssen, Ansarin; Alterio, Daniela; Cossu Rocca, Maria; Grana, Chiara; Ruju, Francesca; Bellomi, Massimo

    2016-12-01

    To assess the independent prognostic value of standardized uptake value (SUV) and apparent diffusion coefficient (ADC), separately and combined, in order to evaluate if the combination of these two variables allows further prognostic stratification of patients with head and neck squamous cell carcinomas (HNSCC). Pretreatment SUV and ADC were calculated in 57 patients with HNSCC. Mean follow-up was 21.3 months. Semiquantitative analysis of primary tumours was performed using SUV maxT/B , ADC mean , ADC min and ADC max . The prognostic value of SUV maxT/B , ADC mean , ADC min and ADC max in predicting disease-free survival (DFS) was evaluated with log-rank test and Cox regression models. Patients with SUV maxT/B ≥5.75 had an overall worse prognosis (p = 0.003). After adjusting for lymph node status and diameter, SUV maxT/B and ADC min were both significant predictors of DFS with hazard ratio (HR) = 10.37 (95 % CI 1.22-87.95) and 3.26 (95 % CI 1.20-8.85) for SUV maxT/B ≥5.75 and ADC min ≥0.58 × 10 -3 mm 2 /s, respectively. When the analysis was restricted to subjects with SUV maxT/B ≥5.75, high ADC min significantly predicted a worse prognosis, with adjusted HR = 3.11 (95 % CI 1.13-8.55). The combination of SUV maxT/B and ADC min improves the prognostic role of the two separate parameters; patients with high SUV maxT/B and high ADC min are associated with a poor prognosis. • High SUV maxT/B is a poor prognostic factor in HNSCC • High ADC min is a poor prognostic factor in HNSCC • In patients with high SUV maxT/B , high ADC min identified those with worse prognosis.

  17. Effective Diffusion Coefficients in Coal Chars

    DEFF Research Database (Denmark)

    Johnsson, Jan Erik; Jensen, Anker

    2001-01-01

    Knowledge of effective diffusion coefficients in char particles is important when interpreting experimental reactivity measurements and modeling char combustion or NO and N2O reduction. In this work, NO and N2O reaction with a bituminous coal char was studied in a fixed-bed quartz glass reactor....... In the case of strong pore diffusion limitations, the error in the interpretation of experimental results using the mean pore radius could be a factor of 5 on the intrinsic rate constant. For an average coal char reacting with oxygen at 1300 K, this would be the case for particle sizes larger than about 50...

  18. Correlation of the apparent diffusion coefficient (ADC with the standardized uptake value (SUV in lymph node metastases of non-small cell lung cancer (NSCLC patients using hybrid 18F-FDG PET/MRI.

    Directory of Open Access Journals (Sweden)

    Benedikt Michael Schaarschmidt

    Full Text Available To compare the apparent diffusion coefficient (ADC in lymph node metastases of non-small cell lung cancer (NSCLC patients with standardized uptake values (SUV derived from combined 18F-fluoro-deoxy-glucose-positron emission tomography/magnetic resonance imaging (18F-FDG PET/MRI.38 patients with histopathologically proven NSCLC (mean age 60.1 ± 9.5 y received whole-body PET/CT (Siemens mCT™ 60 min after injection of a mean dose of 280 ± 50 MBq 18F-FDG and subsequent PET/MRI (mean time after tracer injection: 139 ± 26 min, Siemens Biograph mMR. During PET acquisition, simultaneous diffusion-weighted imaging (DWI, b values: 0, 500, 1000 s/mm² was performed. A maximum of 10 lymph nodes per patient suspicious for malignancy were analyzed. Regions of interest (ROI were drawn covering the entire lymph node on the attenuation-corrected PET-image and the monoexponential ADC-map. According to histopathology or radiological follow-up, lymph nodes were classified as benign or malignant. Pearson's correlation coefficients were calculated for all lymph node metastases correlating SUVmax and SUVmean with ADCmean.A total of 146 suspicious lymph nodes were found in 25 patients. One hundred lymph nodes were eligible for final analysis. Ninety-one lymph nodes were classified as malignant and 9 as benign according to the reference standard. In malignant lesions, mean SUVmax was 9.1 ± 3.8 and mean SUVmean was 6.0 ± 2.5 while mean ADCmean was 877.0 ± 128.6 x10(-5 mm²/s in PET/MRI. For all malignant lymph nodes, a weak, inverse correlation between SUVmax and ADCmean as well as SUVmean and ADCmean (r = -0.30, p<0.05 and r = -0.36, p<0.05 existed.The present data show a weak inverse correlation between increased glucose-metabolism and cellularity in lymph node metastases of NSCLC patients. 18F-FDG-PET and DWI thus may offer complementary information for the evaluation of treatment response in lymph node metastases of NSCLC.

  19. Diffusion tensor MRI: clinical applications

    International Nuclear Information System (INIS)

    Meli, Francisco; Romero, Carlos; Carpintiero, Silvina; Salvatico, Rosana; Lambre, Hector; Vila, Jose

    2005-01-01

    Purpose: To evaluate the usefulness of diffusion-tensor imaging (DTI) on different neurological diseases, and to know if this technique shows additional information than conventional Magnetic Resonance Imaging (MRI). Materials and method: Eight patients, with neurological diseases (five patients with brain tumors, one with multiple sclerosis (MS), one with variant Creutzfeldt-Jakob disease (vCJD) and the other with delayed CO intoxication were evaluated. A MR scanner of 1.5 T was used and conventional sequences and DTI with twenty-five directions were done. Quantitative maps were gotten, where the fractional anisotropy (FA) through regions of interest (ROIs) in specific anatomic area were quantified (i.e.: internal and external capsules, frontal and temporal bundles, corpus fibers). Results: In the patients with brain tumors, there was a decrease of FA on intra and peritumoral fibers. Some of them had a disruption in their pattern. In patients with MS and CO intoxication, partial interruption along white matter bundles was demonstrated. However, a 'mismatch' between the findings of FLAIR, Diffusion-weighted images (DWI) and DTI, in the case of CO intoxication, was seen. Conclusions: DTI gave more information compared to conventional sequences about ultrastructural brain tissue in almost all the diseases above mentioned. Therefore, there is a work in progress about DTI acquisition, to evaluate a new technique, called tractography. (author)

  20. Diffusion-weighted MRI in cervical cancer

    International Nuclear Information System (INIS)

    McVeigh, Patrick Z.; Haider, Masoom A.; Syed, Aejaz M.; Milosevic, Michael; Fyles, Anthony

    2008-01-01

    The purpose was to investigate the potential value of apparent diffusion coefficient (ADC) measurement with MRI in the assessment of cervix cancer. Diffusion-weighted MRI was performed in 47 patients with cervical carcinoma undergoing chemoradiation therapy and 26 normal controls on a 1.5-T system with a b-value of 600 s/mm 2 . FIGO stage, tumor volume, nodal status, interstitial fluid pressure (IFP) and oxygen measurements were recorded. Response was defined as no visible tumor 3-6 months following completion of therapy. The average median ADC (mADC) of cervical carcinomas (1.09±0.20 x 10 -3 mm 2 /s) was significantly lower than normal cervix (2.09±0.46 x 10 -3 mm 2 /s) (P -3 mm 2 /s) compared to T2b (1.21 x 10 -3 mm 2 /s) and T3/T4 (1.10 x 10 -3 mm 2 /s) (P<0.001). In patients with squamous carcinomas the 90th percentile of ADC values was lower in responders than non-responders (P<0.05). Median ADC in cervix carcinoma is significantly lower compared to normal cervix. ADC may have predictive value in squamous tumors, but further long-term study will determine the ultimate clinical utility. (orig.)

  1. Fractal diffusion coefficient from dynamical zeta functions

    Energy Technology Data Exchange (ETDEWEB)

    Cristadoro, Giampaolo [Max Planck Institute for the Physics of Complex Systems, Noethnitzer Str. 38, D 01187 Dresden (Germany)

    2006-03-10

    Dynamical zeta functions provide a powerful method to analyse low-dimensional dynamical systems when the underlying symbolic dynamics is under control. On the other hand, even simple one-dimensional maps can show an intricate structure of the grammar rules that may lead to a non-smooth dependence of global observables on parameters changes. A paradigmatic example is the fractal diffusion coefficient arising in a simple piecewise linear one-dimensional map of the real line. Using the Baladi-Ruelle generalization of the Milnor-Thurnston kneading determinant, we provide the exact dynamical zeta function for such a map and compute the diffusion coefficient from its smallest zero. (letter to the editor)

  2. Fractal diffusion coefficient from dynamical zeta functions

    International Nuclear Information System (INIS)

    Cristadoro, Giampaolo

    2006-01-01

    Dynamical zeta functions provide a powerful method to analyse low-dimensional dynamical systems when the underlying symbolic dynamics is under control. On the other hand, even simple one-dimensional maps can show an intricate structure of the grammar rules that may lead to a non-smooth dependence of global observables on parameters changes. A paradigmatic example is the fractal diffusion coefficient arising in a simple piecewise linear one-dimensional map of the real line. Using the Baladi-Ruelle generalization of the Milnor-Thurnston kneading determinant, we provide the exact dynamical zeta function for such a map and compute the diffusion coefficient from its smallest zero. (letter to the editor)

  3. Diffusion coefficient calculations for cylindrical cells

    International Nuclear Information System (INIS)

    Lam-Hime, M.

    1983-03-01

    An accurate and general diffusion coefficient calculation for cylindrical cells is described using isotropic scattering integral transport theory. This method has been particularly applied to large regular lattices of graphite-moderated reactors with annular coolant channels. The cells are divided into homogeneous zones, and a zone-wise flux expansion is used to formulate a collision probability problem. The reflection of neutrons at the cell boundary is accounted for by the conservation of the neutron momentum. The uncorrected diffusion coefficient Benoist's definition is used, and the described formulation does not neglect any effect. Angular correlation terms, energy coupling non-uniformity and anisotropy of the classical flux are exactly taken into account. Results for gas-graphite typical cells are given showing the importance of these approximations

  4. 2015 MICCAI Workshop on Computational Diffusion MRI

    CERN Document Server

    Ghosh, Aurobrata; Kaden, Enrico; Rathi, Yogesh; Reisert, Marco

    2016-01-01

    These Proceedings of the 2015 MICCAI Workshop “Computational Diffusion MRI” offer a snapshot of the current state of the art on a broad range of topics within the highly active and growing field of diffusion MRI. The topics vary from fundamental theoretical work on mathematical modeling, to the development and evaluation of robust algorithms, new computational methods applied to diffusion magnetic resonance imaging data, and applications in neuroscientific studies and clinical practice. Over the last decade interest in diffusion MRI has exploded. The technique provides unique insights into the microstructure of living tissue and enables in-vivo connectivity mapping of the brain. Computational techniques are key to the continued success and development of diffusion MRI and to its widespread transfer into clinical practice. New processing methods are essential for addressing issues at each stage of the diffusion MRI pipeline: acquisition, reconstruction, modeling and model fitting, image processing, fiber t...

  5. Apparent diffusion coefficient measurements in progressive supranuclear palsy

    Energy Technology Data Exchange (ETDEWEB)

    Ohshita, T.; Oka, M.; Imon, Y.; Yamaguchi, S.; Mimori, Y.; Nakamura, S. [Hiroshima Univ. (Japan). School of Medicine

    2000-09-01

    We measured the apparent diffusion coefficient (ADC), using diffusion-weighted imaging (DWI) and signal intensity on T2-weighted MRI in the cerebral white matter of patients with progressive supranuclear palsy (PSP) and age-matched normal subjects. In PSP, ADC in the prefrontal and precentral white matter was significantly higher than in controls. There was no significant difference in signal intensity on T2-weighted images. The ADC did correlate with signal intensity. The distribution of the elevation of ADC may be the consequence of underlying pathological changes, such as neurofibrillary tangles or glial fibrillary tangles in the cortex. Our findings suggest that ADC measurement might be useful for demonstrating subtle neuropathological changes. (orig.)

  6. Local diffusion coefficient determination: Mediterranean Sea experiments

    International Nuclear Information System (INIS)

    Bacciola, D.; Borghini, M.; Cannarsa, S.

    1993-10-01

    The Mediterranean is a semi/enclosed basin characterized by the presence of channels and straits influencing the circulation, temperature and salinity fields. The tides generally have amplitudes of the order of 10 cm and velocities of few cm/s. Conversely, the wind forced circulation is very strong and can assume velocity values of 1 m/s at the sea surface. The temperature and salinity fields have a high temporal and spatial variability, because of many mixing processes existing in the sea. For example, the waters coming from the Provencal basin meet those waters coming from the Tyrrhenian Sea in the eastern Ligurian Sea, creating meanders and eddies. Local runoff influences significantly the coastal circulation. This paper describes diffusion experiments carried out in this complex environment. The experimental apparatus for the detection of the fluorescine released at sea was composed by two Turner mod. 450 fluorometres. During the experiments, temperature and salinity vertical profiles were measured by using a CTD; meteorological data were acquired on a dinghy. The positioning was obtained by means of a Motorola system, having a precision of about 1 meter. The experiments were carried out under different stratification and wind conditions. From data analysis it was found that the horizontal diffusion coefficient does not depend on time or boundary conditions. The role of stratification is important with regard to vertical displacement of the dye. However, its role with regard to vertical diffusion cannot be assessed with the actual experimental apparatus

  7. Correlating tumor metabolic progression index measured by serial FDG PET-CT, apparent diffusion coefficient measured by magnetic resonance imaging (MRI) and blood genomics to patient’s outcome in advanced colorectal cancer: the CORIOLAN study

    International Nuclear Information System (INIS)

    Deleporte, Amelie; Charette, Nicolas; Machiels, Godelieve; Piccart, Martine; Flamen, Patrick; Hendlisz, Alain; Paesmans, Marianne; Garcia, Camilo; Vandeputte, Caroline; Lemort, Marc; Engelholm, Jean-Luc; Hoerner, Frederic; Aftimos, Philippe; Awada, Ahmad

    2014-01-01

    Metastatic colorectal cancer (mCRC) may present various behaviours that define different courses of tumor evolution. There is presently no available tool designed to assess tumor aggressiveness, despite the fact that this is considered to have a major impact on patient outcome. CORIOLAN is a single-arm prospective interventional non-therapeutic study aiming mainly to assess the natural tumor metabolic progression index (TMPI) measured by serial FDG PET-CT without any intercurrent antitumor therapy as a prognostic factor for overall survival (OS) in patients with mCRC. Secondary objectives of the study aim to test the TMPI as a prognostic marker for progression-free survival (PFS), to assess the prognostic value of baseline tumor FDG uptake on PFS and OS, to compare TMPI to classical clinico-biological assessment of prognosis, and to test the prognostic value on OS and PFS of MRI-based apparent diffusion coefficient (ADC) and variation of vADC using voxel-based diffusion maps. Additionally, this study intends to identify genomic and epigenetic factors that correlate with progression of tumors and the OS of patients with mCRC. Consequently, this analysis will provide information about the signaling pathways that determine the natural and therapy-free course of the disease. Finally, it would be of great interest to investigate whether in a population of patients with mCRC, for which at present no known effective therapy is available, tumor aggressiveness is related to elevated levels of circulating tumor cells (CTCs) and to patient outcome. Tumor aggressiveness is one of the major determinants of patient outcome in advanced disease. Despite its importance, supported by findings reported in the literature of extreme outcomes for patients with mCRC treated with chemotherapy, no objective tool allows clinicians to base treatment decisions on this factor. The CORIOLAN study will characterize TMPI using FDG-PET-based metabolic imaging of patients with chemorefractory m

  8. Diffusion-weighted MRI of maple syrup urine disease encephalopathy

    Energy Technology Data Exchange (ETDEWEB)

    Cavalleri, F.; Mavilla, L. [Servizio di Neuroradiologia, Azienda Ospedaliera Policlinico, Modena (Italy); Berardi, A.; Ferrari, F. [Servizio di Neonatologia, Azienda Ospedaliera Policlinico, Modena (Italy); Burlina, A.B. [Dipartimento di Pediatria, Azienda Ospedaliera, Universita di Padova, Padua (Italy)

    2002-06-01

    We report the case of a newborn child with maple syrup urine disease (MSUD), diagnosed at 10 days of life. Diffusion-weighted echoplanar MRI showed marked hyperintensity of the cerebellar white matter, the brainstem, the cerebral peduncles, the thalami, the dorsal limb of the internal capsule and the centrum semiovale, while conventional dual-echo sequence evidenced only a weak diffuse T2 hyperintensity in the cerebellar white matter and in the dorsal brainstem. The apparent diffusion coefficient (ADC) of these regions was markedly (>80%) decreased. Therefore, in agreement with current hypotheses on MSUD pathogenesis, MSUD oedema proves to be a cytotoxic oedema. Diffusion-weighted MRI may be a valuable tool, more sensitive than conventional spin-echo techniques, to assess the extent and progression of cytotoxicity in MSUD, as well as the effectiveness of the therapeutic interventions. (orig.)

  9. Diffusion-weighted MRI of maple syrup urine disease encephalopathy

    International Nuclear Information System (INIS)

    Cavalleri, F.; Mavilla, L.; Berardi, A.; Ferrari, F.; Burlina, A.B.

    2002-01-01

    We report the case of a newborn child with maple syrup urine disease (MSUD), diagnosed at 10 days of life. Diffusion-weighted echoplanar MRI showed marked hyperintensity of the cerebellar white matter, the brainstem, the cerebral peduncles, the thalami, the dorsal limb of the internal capsule and the centrum semiovale, while conventional dual-echo sequence evidenced only a weak diffuse T2 hyperintensity in the cerebellar white matter and in the dorsal brainstem. The apparent diffusion coefficient (ADC) of these regions was markedly (>80%) decreased. Therefore, in agreement with current hypotheses on MSUD pathogenesis, MSUD oedema proves to be a cytotoxic oedema. Diffusion-weighted MRI may be a valuable tool, more sensitive than conventional spin-echo techniques, to assess the extent and progression of cytotoxicity in MSUD, as well as the effectiveness of the therapeutic interventions. (orig.)

  10. The predictability for the prognosis of breast cancer using the apparent diffusion coefficient value of diffusion weighted 3T MRI and the standardized uptake value of positron emission tomography/CT: Assessment of prognostic factor

    International Nuclear Information System (INIS)

    Lim, Seong Joo; Kim, Keum Won; Jang, Hye Young; Hwang, Cheol Mog; Kim, Dae Ho; Sohn, Jang Sihn; Kim, Jin Suk; Lee, Jin Yong

    2012-01-01

    To correlate the apparent diffusion coefficient (ADC) value and peak standardized uptake value (pSUV) with histologic grade and clinical prognostic factors of breast ductal carcinoma. Fifty breast cancers of 49 patients (age range: 37-83 years, mean: 53 years) were studied retrospectively. The breast cancers included 4 ductal carcinoma in situ (DCIS) and 46 invasive ductal carcinomas (IDC). The relationships for both pSUV and ADC values with clinicopathological prognostic factors (age, tumor size, histologic grade, nodal metastasis, hormone receptor and HER-2 neu status) were statistically evaluated. The histologic type of ductal carcinoma include DCIS (n = 4) and IDC (n = 46, grade 1 = 10, grade 2 = 13, and grade 3 = 23). pSUV was associated with histologic grade and tumor size and the ADC value was associated with histologic grade (p < 0.05). As the histologic grade becomes higher, the ADC values decrease, while pSUV and pSUV/ADC increase (p < 0.05). The characterization accuracy of pSUV/ADC (90.2%) was higher than pSUV (86.7%) and ADC values (25.4%) alone for the diagnosis of breast cancer (p < 0.05). pSUV and ADC values correlated with histologic grade, and tumor size. The pSUV/ADC value had a high accuracy for the diagnosis of breast cancer. Therefore, pSUV and ADC values provided additional information for predicting histologic grade and prognosis of breast cancer

  11. Tuberous sclerosis: diffusion MRI findings in the brain

    International Nuclear Information System (INIS)

    Sener, R.N.

    2002-01-01

    Diffusion MRI has mainly been used for detection of acute ischemia, and for distinction of cytotoxic and vasogenic edema. We applied diffusion MRI in patients with tuberous sclerosis in order to evaluate diffusion imaging characteristics of parenchymal changes. Five children with known tuberous sclerosis were included in this study. The MRI examinations were performed on a 1.5-T MR unit. Diffusion MRI was obtained using the echo-planar imaging sequence. Apparent diffusion coefficient (ADC) values from the abnormal brain parenchyma were calculated directly from automatically generated ADC maps. Seven normal children were available for comparison. In this control group the mean ADC value of the normal white matter was 0.84±0.12 x 10 -3 mm 2 /s. In tuberous sclerosis patients the mean ADC value of the white matter hamartomas (n=20) was apparently high (1.52±0.24 x 10 -3 mm 2 /s) compared with that of normal white matter. The ADC value of calcified hamartomas was ''zero''. The ADC value within a giant cell tumor was 0.89 x 10 -3 mm 2 /s, similar to that of normal cerebral white matter. The ADC maps were superior to b=1000 s/mm 2 (true diffusion) images with respect to lesion evaluation, and they provided mathematical information on tissue integrity. With respect to detection of the exact numbers and sizes of the parenchymal hamartomas fluid-attenuated inversion recovery images were superior to ADC maps. It is believed that diffusion MRI can be useful in evaluation of various parenchymal changes associated with tuberous sclerosis. Further studies on tuberous sclerosis, and on various brain lesions, would provide increasing data on this relatively new MRI sequence. (orig.)

  12. Stochastic Modelling of the Diffusion Coefficient for Concrete

    DEFF Research Database (Denmark)

    Thoft-Christensen, Palle

    In the paper, a new stochastic modelling of the diffusion coefficient D is presented. The modelling is based on physical understanding of the diffusion process and on some recent experimental results. The diffusion coefficients D is strongly dependent on the w/c ratio and the temperature....

  13. Bayesian uncertainty quantification in linear models for diffusion MRI.

    Science.gov (United States)

    Sjölund, Jens; Eklund, Anders; Özarslan, Evren; Herberthson, Magnus; Bånkestad, Maria; Knutsson, Hans

    2018-03-29

    Diffusion MRI (dMRI) is a valuable tool in the assessment of tissue microstructure. By fitting a model to the dMRI signal it is possible to derive various quantitative features. Several of the most popular dMRI signal models are expansions in an appropriately chosen basis, where the coefficients are determined using some variation of least-squares. However, such approaches lack any notion of uncertainty, which could be valuable in e.g. group analyses. In this work, we use a probabilistic interpretation of linear least-squares methods to recast popular dMRI models as Bayesian ones. This makes it possible to quantify the uncertainty of any derived quantity. In particular, for quantities that are affine functions of the coefficients, the posterior distribution can be expressed in closed-form. We simulated measurements from single- and double-tensor models where the correct values of several quantities are known, to validate that the theoretically derived quantiles agree with those observed empirically. We included results from residual bootstrap for comparison and found good agreement. The validation employed several different models: Diffusion Tensor Imaging (DTI), Mean Apparent Propagator MRI (MAP-MRI) and Constrained Spherical Deconvolution (CSD). We also used in vivo data to visualize maps of quantitative features and corresponding uncertainties, and to show how our approach can be used in a group analysis to downweight subjects with high uncertainty. In summary, we convert successful linear models for dMRI signal estimation to probabilistic models, capable of accurate uncertainty quantification. Copyright © 2018 Elsevier Inc. All rights reserved.

  14. Assessment of satellite derived diffuse attenuation coefficients ...

    Science.gov (United States)

    Optical data collected in coastal waters off South Florida and in the Caribbean Sea between January 2009 and December 2010 were used to evaluate products derived with three bio-optical inversion algorithms applied to MOIDS/Aqua, MODIS/Terra, and SeaWiFS satellite observations. The products included the diffuse attenuation coefficient at 490 nm (Kd_490) and for the visible range (Kd_PAR), and euphotic depth (Zeu, corresponding to 1% of the surface incident photosynthetically available radiation or PAR). Above-water hyperspectral reflectance data collected over optically shallow waters of the Florida Keys between June 1997 and August 2011 were used to help understand algorithm performance over optically shallow waters. The in situ data covered a variety of water types in South Florida and the Caribbean Sea, ranging from deep clear waters, turbid coastal waters, and optically shallow waters (Kd_490 range of ~0.03 – 1.29m-1). An algorithm based on Inherent Optical Properties (IOPs) showed the best performance (RMSD turbidity or shallow bottom contamination. Similar results were obtained when only in situ data were used to evaluate algorithm performance. The excellent agreement between satellite-derived remote sensing reflectance (Rrs) and in situ Rrs suggested that

  15. Measurement of the apparent diffusion coefficient in paediatric mitochondrial encephalopathy cases and a comparison of parenchymal changes associated with the disease using follow-up diffusion coefficient measurements

    Energy Technology Data Exchange (ETDEWEB)

    Uysal, Fatma, E-mail: afatmauysal@gmail.com [Dokuz Eylül University, Department of Pediatric Radiology, Izmir (Turkey); Çakmakçı, Handan, E-mail: handan.cakmakci@deu.edu.tr [Dokuz Eylül University, Department of Pediatric Radiology, Izmir (Turkey); Yiş, Uluç, E-mail: ulucyis@deu.edu.tr [Dokuz Eylül University, Department of Pediatric Neurology, Izmir (Turkey); Ellidokuz, Hülya, E-mail: hulyaellidokuz@deu.edu.tr [Dokuz Eylül University, Department of Medical Statistics, Izmir (Turkey); Hız, Ayşe Semra, E-mail: aysesemrahiz@deu.edu.tr [Dokuz Eylül University, Department of Pediatric Neurology, Izmir (Turkey)

    2014-01-15

    Objectives: To reveal the contribution of MRI and diffusion-weighted imaging (DWI) to the diagnosis of mitochondrial encephalopathy (ME) and to evaluate the parenchymal changes associated with this disease in the involved parenchymal areas using the apparent diffusion coefficient (ADC) parameter. Methods: Ten patients who had undergone MRI and DWI analysis with a pre-diagnosis of neurometabolic disease, and who were subsequently diagnosed with ME in laboratory and/or genetic studies, were included in our study. ADC values were compared with a control group composed of 20 patients of similar age with normal brains. Evaluations involved measurements made in 20 different areas determined on the ADC map. The dominance or contribution of ADC coefficient measurements to the conventional sequences was compared with the controls. Results: In the first examination, an increase in both diffusion and ADC values was detected in six cases and diffusion restriction and a decrease in ADC values in three patients. While an increase in both diffusion and ADC values was demonstrated in four cases, there was diffusion restriction and a decrease in ADC values in three cases in the control examinations. Conclusions: DWI provides information that complements conventional MRI sequences in the diagnosis of ME.

  16. Diffusion coefficient of three-dimensional Yukawa liquids

    International Nuclear Information System (INIS)

    Dzhumagulova, K. N.; Ramazanov, T. S.; Masheeva, R. U.

    2013-01-01

    The purpose of this work is an investigation of the diffusion coefficient of the dust component in complex plasma. The computer simulation of the Yukawa liquids was made on the basis of the Langevin equation, which takes into account the influence of buffer plasma on the dust particles dynamics. The Green–Kubo relation was used to calculate the diffusion coefficient. Calculations of the diffusion coefficient for a wide range of the system parameters were performed. Using obtained numerical data, we constructed the interpolation formula for the diffusion coefficient. We also show that the interpolation formula correctly describes experimental data obtained under microgravity conditions

  17. Imaging brain microstructure with diffusion MRI

    DEFF Research Database (Denmark)

    Alexander, Daniel C; Dyrby, Tim B; Nilsson, Markus

    2018-01-01

    This article gives an overview of microstructure imaging of the brain with diffusion MRI and reviews the state of the art. The microstructure-imaging paradigm aims to estimate and map microscopic properties of tissue using a model that links these properties to the voxel scale MR signal. Imaging ...

  18. Quantifying Pathology in Diffusion Weighted MRI

    NARCIS (Netherlands)

    Caan, M.W.A.

    2010-01-01

    In this thesis algorithms are proposed for quantification of pathology in Diffusion Weighted Magnetic Resonance Imaging (DW-MRI) data. Functional evidence for brain diseases can be explained by specific structural loss in the white matter of the brain. That is, certain biomarkers may exist where the

  19. MRI: update on technology diffusion and acquisition.

    Science.gov (United States)

    Hoppszallern, S; Hughes, C; Zimmerman, R A

    1991-04-01

    Over the past three years, magnetic resonance imaging (MRI) has become accepted as a valuable diagnostic tool, and its applications continue to expand. During this time, the number of units installed in the United States doubled. By 1990 about 2,000 MRI units were in place in the United States and nearly 20 percent of the MRI-installed base was mobile, according to a research study conducted by the Hadley Hart Group (Chicago) and Drew Consultants, Inc. (Concord, MA). With the introduction of the prospective payment system, many hospitals were hesitant to spend limited capital on new technology, such as MRI. At the same time, freestanding diagnostic imaging centers were on the rise. Some hospitals and entrepreneurs who foresaw the potential of MRI in health care pioneered its use in the clinical setting. Hospitals began to examine new partnership arrangements and alternative forms of financing, so that they too could offer MRI services. By the end of 1988, the majority of hospitals offering MRI services did not own their own unit and about 40 percent of the hospitals offering MRI services were in a mobile configuration according to the Hadley Hart Group. While the technology has been diffused into 100-bed hospitals via mobile service vendors in some parts of the country, many medium-sized and large hospitals also have entered the MRI services market in this fashion. In the larger hospitals, the patient demand or need for the service often would justify acquisition of MRI, but the expense of the technology, and in many areas restrictive state health planning policies, modified purchase of MRI systems by hospitals. Mobile service vendors offered hospitals a way to startup MRI services in a limited fashion without a major capital expenditure and its associated risk. As hospitals gain experience with mobile MRI and achieve or exceed their early utilization projections, administrators are reevaluating the need to expand services to a full-time fixed site. Early fixed

  20. Diffusion coefficient adaptive correction in Lagrangian puff model

    International Nuclear Information System (INIS)

    Tan Wenji; Wang Dezhong; Ma Yuanwei; Ji Zhilong

    2014-01-01

    Lagrangian puff model is widely used in the decision support system for nuclear emergency management. The diffusion coefficient is one of the key parameters impacting puff model. An adaptive method was proposed in this paper, which could correct the diffusion coefficient in Lagrangian puff model, and it aimed to improve the accuracy of calculating the nuclide concentration distribution. This method used detected concentration data, meteorological data and source release data to estimate the actual diffusion coefficient with least square method. The diffusion coefficient adaptive correction method was evaluated by Kincaid data in MVK, and was compared with traditional Pasquill-Gifford (P-G) diffusion scheme method. The results indicate that this diffusion coefficient adaptive correction method can improve the accuracy of Lagrangian puff model. (authors)

  1. Determination of the diffusion coefficient of hydrogen ion in hydrogels.

    Science.gov (United States)

    Schuszter, Gábor; Gehér-Herczegh, Tünde; Szűcs, Árpád; Tóth, Ágota; Horváth, Dezső

    2017-05-17

    The role of diffusion in chemical pattern formation has been widely studied due to the great diversity of patterns emerging in reaction-diffusion systems, particularly in H + -autocatalytic reactions where hydrogels are applied to avoid convection. A custom-made conductometric cell is designed to measure the effective diffusion coefficient of a pair of strong electrolytes containing sodium ions or hydrogen ions with a common anion. This together with the individual diffusion coefficient for sodium ions, obtained from PFGSE-NMR spectroscopy, allows the determination of the diffusion coefficient of hydrogen ions in hydrogels. Numerical calculations are also performed to study the behavior of a diffusion-migration model describing ionic diffusion in our system. The method we present for one particular case may be extended for various hydrogels and diffusing ions (such as hydroxide) which are relevant e.g. for the development of pH-regulated self-healing mechanisms and hydrogels used for drug delivery.

  2. Diffusion coefficients gases, dissolved in fluid of NPPs circulation contours

    International Nuclear Information System (INIS)

    Piontkovskij, A.I.

    2000-01-01

    In article is brought analysis of diverse gases diffusion coefficients computation methods, dissolved in liquid. On the basis of this analysis and treatment of being equalizations for concrete gases and certain parameters offers universal diffusion coefficients determination dependence for diverse gases in wide range of parameters, circulation contours typical for work NPP

  3. Measurement of chemical diffusion coefficients in liquid binary alloys

    International Nuclear Information System (INIS)

    Keita, M.; Steinemann, S.; Kuenzi, H.U.

    1976-01-01

    New measurements of the chemical diffusion coefficient in liquid binary alloys are presented. The wellknown geometry of the 'capillary-reservoir' is used and the concentration is obtained from a resistivity measurement. The method allows to follow continuously the diffusion process in the liquid state. A precision of at least 10% in the diffusion coefficient is obtained with a reproductibility better than 5%. The systems Hg-In, Al-Sn, Al-Si have been studied. Diffusion coefficients are obtained as a function of temperature, concentration, and geometrical factors related to the capillary (diameter, relative orientation of density gradient and gravity). (orig.) [de

  4. Determination of ion diffusion coefficients by the electromigration method

    International Nuclear Information System (INIS)

    Bonchev, G.D.; Milanov, M.V.; Bozhikov, G.A.; Ivanov, P.I.; Priemyshev, A.N.; Maslov, O.D.; Dmitriev, S.N.

    2003-01-01

    An electrophoretic method for measuring ion diffusion coefficients in aqueous solutions is developed. The value of the diffusion coefficient can be determined from the linear relationship between the square standard deviation of the electrophoretic zone and the time from the start of the diffusion process. Using the device for horizontal zone electrophoresis in a free electrolyte, a series of diffusion experiments are performed with no-carrier-added radionuclides in microconcentrations (10 -9 - 10 -10 M). Diffusion coefficients of 111 In(III), 175 Hf(IV) and 237 Pu(VI) ions at 25 0 C are determined in nitric acid media. Simultaneous determination of the diffusion coefficient and electrophoretic mobility allows one to calculate the effective charge of the investigated ions in accordance with the Nernst-Einstein law

  5. Analysis and visualization methods for interpretation of diffusion MRI data

    NARCIS (Netherlands)

    Vos, S.B.

    2013-01-01

    Diffusion MRI is an imaging technique that is very sensitive to microstructural changes in tissue. Diffusion tensor MRI, the most commonly used method, can estimate the magnitude and anisotropy of diffusion. These tensor-based diffusion parameters have been shown to change in many neuropathological

  6. Role of magnetic resonance diffusion imaging and apparent diffusion coefficient values in the evaluation of spinal tuberculosis in Indian patients

    International Nuclear Information System (INIS)

    Palle, Lalitha; Reddy, MCH Balaji; Reddy, K Jagannath

    2010-01-01

    To define a range of apparent diffusion coefficient values in spinal tuberculosis and to evaluate the sensitivity of diffusion-weighted magnetic resonance imaging (DW-MRI) and apparent diffusion coefficient values in patients of spinal tuberculosis. This study was conducted over a period of 20 months and included 110 patients with a total of 230 vertebral bodies. The study was performed in two parts. The first part included all patients of known tuberculosis and patients with classical features of tuberculosis. The second part included patients with spinal pathology of indeterminate etiology. All the patients underwent a routine MRI examination along with diffusion sequences. The apparent diffusion coefficient (ADC) values were calculated from all the involved vertebral bodies. The mean ADC value of affected vertebrae in first part of the study was found to be 1.4 ± 0.20 × 10 −3 mm 2 /s. This ADC value was then applied to patients in the second part of study in order to determine its ability in predicting tuberculosis. This range of ADC values was significantly different from the mean ADC values of normal vertebrae and those with metastatic involvement. However, there was an overlap of ADC values in a few tuberculous vertebrae with the ADC values in metastatic vertebrae. We found that DW-MRI and ADC values may help in the differentiation of spinal tuberculosis from other lesions of similar appearance. However, an overlap of ADC values was noted with those of metastatic vertebrae. Therefore diffusion imaging and ADC values must always be interpreted in association with clinical history and routine MRI findings and not in isolation

  7. Monte Carlo based diffusion coefficients for LMFBR analysis

    International Nuclear Information System (INIS)

    Van Rooijen, Willem F.G.; Takeda, Toshikazu; Hazama, Taira

    2010-01-01

    A method based on Monte Carlo calculations is developed to estimate the diffusion coefficient of unit cells. The method uses a geometrical model similar to that used in lattice theory, but does not use the assumption of a separable fundamental mode used in lattice theory. The method uses standard Monte Carlo flux and current tallies, and the continuous energy Monte Carlo code MVP was used without modifications. Four models are presented to derive the diffusion coefficient from tally results of flux and partial currents. In this paper the method is applied to the calculation of a plate cell of the fast-spectrum critical facility ZEBRA. Conventional calculations of the diffusion coefficient diverge in the presence of planar voids in the lattice, but our Monte Carlo method can treat this situation without any problem. The Monte Carlo method was used to investigate the influence of geometrical modeling as well as the directional dependence of the diffusion coefficient. The method can be used to estimate the diffusion coefficient of complicated unit cells, the limitation being the capabilities of the Monte Carlo code. The method will be used in the future to confirm results for the diffusion coefficient obtained of the Monte Carlo code. The method will be used in the future to confirm results for the diffusion coefficient obtained with deterministic codes. (author)

  8. Imaging and assessment of diffusion coefficients by magnetic resonance

    International Nuclear Information System (INIS)

    Tintera, J.; Dezortova, M.; Hajek, M.; Fitzek, C.

    1999-01-01

    The problem of assessment of molecular diffusion by magnetic resonance is highlighted and some typical applications of diffusion imaging in the diagnosis, e.g., of cerebral ischemia, changes in patients with phenylketonuria or multiple sclerosis are discussed. The images were obtained by using diffusion weighted spin echo Echo-Planar Imaging sequence with subsequent correction of the geometrical distortion of the images and calculation of the Apparent Diffusion Coefficient map

  9. Elastography and diffusion-weighted MRI in patients with rectal cancer

    DEFF Research Database (Denmark)

    Rafaelsen, Søren Rafael; Vagn-Hansen, Chris Aksel; Sørensen, Torben

    2015-01-01

    -weighted coefficient (ADC). The purpose of the present study was to compare quantitative elastography based on ultrasound shear wave measurements with MRI ADC. METHODS: We prospectively examined 52 patients with histopathologically proven rectal cancer. The mean age was 67 years (range 42-90 years). Males: 39, females...... a correlation between tissue elasticity and diffusion in rectal cancer.......OBJECTIVE: The current literature has described the usefulness of elastography and diffusion-weighted MRI in patients with cancer, but to the best of our knowledge so far none of them has compared the two new methods. The tumour cell density is related to the MRI-measured apparent diffusion...

  10. Improved diffusion coefficients generated from Monte Carlo codes

    International Nuclear Information System (INIS)

    Herman, B. R.; Forget, B.; Smith, K.; Aviles, B. N.

    2013-01-01

    Monte Carlo codes are becoming more widely used for reactor analysis. Some of these applications involve the generation of diffusion theory parameters including macroscopic cross sections and diffusion coefficients. Two approximations used to generate diffusion coefficients are assessed using the Monte Carlo code MC21. The first is the method of homogenization; whether to weight either fine-group transport cross sections or fine-group diffusion coefficients when collapsing to few-group diffusion coefficients. The second is a fundamental approximation made to the energy-dependent P1 equations to derive the energy-dependent diffusion equations. Standard Monte Carlo codes usually generate a flux-weighted transport cross section with no correction to the diffusion approximation. Results indicate that this causes noticeable tilting in reconstructed pin powers in simple test lattices with L2 norm error of 3.6%. This error is reduced significantly to 0.27% when weighting fine-group diffusion coefficients by the flux and applying a correction to the diffusion approximation. Noticeable tilting in reconstructed fluxes and pin powers was reduced when applying these corrections. (authors)

  11. The solubility and diffusion coefficient of helium in uranium dioxide

    International Nuclear Information System (INIS)

    Nakajima, Kunihisa; Serizawa, Hiroyuki; Shirasu, Noriko; Haga, Yoshinori; Arai, Yasuo

    2011-01-01

    Highlights: ► The solubility and diffusivity of He in single-crystal UO 2 were determined. ► The determined He solubility lay within the scatter of the available data. ► The determined He diffusivity was in good agreement with recent experimental data. ► The He behavior was analyzed in terms of a simple interstitial diffusion mechanism. ► The experimental diffusivity was much lower than that analyzed theoretically. - Abstract: The solubility and diffusion coefficient of helium in the single-crystal UO 2 samples were determined by a Knudsen-effusion mass-spectrometric method. The measured helium solubilities were found to lie within the scatter of the available data, but to be much lower than those for the polycrystalline samples. The diffusion analysis was conducted based on a hypothetical equivalent sphere model and the simple Fick’s law. The helium diffusion coefficient was determined by using the pre-exponential factor and activation energy as the fitting parameters for the measured and calculated fractional releases of helium. The optimized diffusion coefficients were in good agreement with those obtained by a nuclear reaction method reported in the past. It was also found that the pre-exponential factors of the determined diffusion coefficients were much lower than those analyzed in terms of a simple interstitial diffusion mechanism.

  12. Local carbon diffusion coefficient measurement in the S-1 spheromak

    International Nuclear Information System (INIS)

    Mayo, R.M.; Levinton, F.M.; Meyerhofer, D.D.; Chu, T.K.; Paul, S.F.; Yamada, M.

    1988-10-01

    The local carbon diffusion coefficient was measured in the S - 1 spheromak by detecting the radial spread of injected carbon impurity. The radial impurity density profile is determined by the balance of ionization and diffusion. Using measured local electron temperature T/sub e/ and density n/sub e/, the ionization rate is determined from which the particle diffusion coefficient is inferred. The results found in this work are consistent with Bohm diffusion. The absolute magnitude of D/sub /perpendicular// was determined to be (4/approximately/6) /times/ D/sub Bohm/. 25 refs., 13 figs., 2 tabs

  13. Diffusion simulation of ferric ions in dosemeter Fricke-gel with variable diffusion coefficient

    International Nuclear Information System (INIS)

    Milani, Caio Jacob; Bevilacqua, Joyce da Silva; Rodrigues Junior, Orlando

    2014-01-01

    Dosimetry using dosimeters Fricke-xylenol-Gel (FXG) allows confirmation and better understanding of radiotherapy treatments. The technique involves the evaluation of volumes irradiated by magnetic resonance imaging (MRI) or CT-optical. In both cases, the time spent between the irradiation and measurement is an important factor that directly influences the results. The quality of the images can be compromised by the mobility of ferric ions (Fe 3+), formed during the interaction of radiation with matter, increasing the uncertainty in determining the isodose. In this work, we simulated the dynamic involving ferric ions formed in one irradiated region irradiated in a two-dimensional domain with a variable diffusion coefficient. This phenomenon is modeled by a differential equation and solved numerically by an efficient algorithm that generalizes the Crank-Nicolson method. The stability and consistency of the method guarantee the convergence of the numerical solution for a predefined tolerance based in the choice of discretization steps of time and space. Different continuous functions were chosen to represent the diffusion coefficient and graphical views of the phenomenon are presented for a better understanding of the process

  14. Calculation of ternary interdiffusion coefficients using a single diffusion couple

    Czech Academy of Sciences Publication Activity Database

    Čermák, Jiří; Rothová, Věra

    2016-01-01

    Roč. 54, č. 5 (2016), s. 305-314 ISSN 0023-432X R&D Projects: GA MŠk(CZ) ED1.1.00/02.0068 Institutional support: RVO:68081723 Keywords : diffusion * interdiffusion * ternary alloys * ternary diffusion coefficients Subject RIV: BJ - Thermodynamics Impact factor: 0.366, year: 2016

  15. Calculation of self-diffusion coefficients in iron

    Directory of Open Access Journals (Sweden)

    Baohua Zhang

    2014-01-01

    Full Text Available On the basis of available P-V-T equation of state of iron, the temperature and pressure dependence of self-diffusion coefficients in iron polymorphs (α, δ, γ and ɛ phases have been successfully reproduced in terms of the bulk elastic and expansivity data by means of a thermodynamical model that interconnects point defects parameters with bulk properties. The calculated diffusion parameters, such as self-diffusion coefficient, activation energy and activation volume over a broad temperature range (500-2500 K and pressure range (0-100 GPa, compare favorably well with experimental or theoretical ones when the uncertainties are considered.

  16. Diffusion coefficients of decay products of radon and thoron

    International Nuclear Information System (INIS)

    Raghunath, B.; Kotrappa, P.

    1979-01-01

    The diffusion coefficients of the decay products of radon and thoron have relevance in the evaluation of inhalation hazards in uranium and thorium processing industries. A recently developed diffusion sampler, based on Mercer's theory of diffusional deposition between the concentric circular plates, has been used for determining the diffusion coefficients of the unattached decay products of radon and thoron (RaA, RaB, RaC and ThB). Experiments were conducted at different ventilation rates (6 and 60 changes/hr) at different relative humidities (10 and 90%) and both in air and argon atmospheres. Diffusion coefficients were found to increase with increasing ventilation rates and were found to decrease at higher relative humidities, the effect being more marked at lower ventilation rates. Both of these effects were less pronounced in argon than in air. Results are discussed in light of the known properties of these decay products. (author)

  17. Anomalous behavior of the diffusion coefficient in thin active films

    International Nuclear Information System (INIS)

    Basu, Abhik; Joanny, Jean-Francois; Prost, Jacques; Jülicher, Frank

    2012-01-01

    Inspired by recent experiments in cell biology, we elucidate the visco-elastic properties of an active gel by studying the dynamics of a small tracer particle inside it. In a stochastic hydrodynamic approach for an active gel of finite thickness L, we calculate the mean square displacement of a particle. These particle displacements are governed by fluctuations in the velocity field. We characterize the short-time behavior when the gel is a solid as well as the limit of long times when the gel becomes a fluid and the particle shows simple diffusion. Active stresses together with local polar order give rise to velocity fluctuations that lead to characteristic behaviors of the diffusion coefficient that differ fundamentally from those found in a passive system: the diffusion coefficient can depend on system size and diverges as L approaches an instability threshold. Furthermore, the diffusion coefficient becomes independent of the particle size in this case. (paper)

  18. Brain microstructure mapping using quantitative and diffusion MRI

    International Nuclear Information System (INIS)

    Lebois, Alice

    2014-01-01

    This thesis is focused on the human brain microstructure mapping using quantitative and diffusion MRI. The T1/T2 quantitative imaging relies on sequences dedicated to the mapping of T1 and T2 relaxation times. Their variations within the tissue are linked to the presence of different water compartments defined by a specific organization of the tissue at the cell scale. Measuring these parameters can help, therefore, to better characterize the brain microstructure. The dMRI, on the other hand, explores the brownian motion of water molecules in the brain tissue, where the water molecules' movement is constrained by natural barriers, such as cell membranes. Thus, the information on their displacement carried by the dMRI signal gives access to the underlying cyto-architecture. Combination of these two modalities is, therefore, a promising way to probe the brain tissue microstructure. The main goal of the present thesis is to set up the methodology to study the microstructure of the white matter of the human brain in vivo. The first part includes the acquisition of a unique MRI database of 79 healthy subjects (the Archi/CONNECT), which includes anatomical high resolution data, relaxometry data, diffusion-weighted data at high spatio-angular resolution and functional data. This database has allowed us to build the first atlas of the anatomical connectivity of the healthy brain through the automatic segmentation of the major white matter bundles, providing an appropriate anatomical reference for the white matter to study individually the quantitative parameters along each fascicle, characterizing its microstructure organization. Emphasis was placed on the construction of the first atlas of the T1/T2 profiles along the major white matter pathways. The profiles of the T1 and T2 relaxation times were then correlated to the quantitative profiles computed from the diffusion MRI data (fractional anisotropy, radial and longitudinal diffusivities, apparent diffusion coefficient

  19. Verifying reciprocal relations for experimental diffusion coefficients in multicomponent mixtures

    DEFF Research Database (Denmark)

    Medvedev, Oleg; Shapiro, Alexander

    2003-01-01

    The goal of the present study is to verify the agreement of the available data on diffusion in ternary mixtures with the theoretical requirement of linear non-equilibrium thermodynamics consisting in symmetry of the matrix of the phenomenological coefficients. A common set of measured diffusion...... coefficients for a three-component mixture consists of four Fickian diffusion coefficients, each being reported separately. However, the Onsager theory predicts the existence of only three independent coefficients, as one of them disappears due to the symmetry requirement. Re-calculation of the Fickian...... extended sets of experimental data and reliable thermodynamic models were available. The sensitivity of the symmetry property to different thermodynamic parameters of the models was also checked. (C) 2003 Elsevier Science B.V. All rights reserved....

  20. Comparison of field-measured radon diffusion coefficients with laboratory-measured coefficients

    International Nuclear Information System (INIS)

    Lepel, E.A.; Silker, W.B.; Thomas, V.W.; Kalkwarf, D.R.

    1983-04-01

    Experiments were conducted to compare radon diffusion coefficients determined for 0.1-m depths of soils by a steady-state method in the laboratory and diffusion coefficients evaluated from radon fluxes through several-fold greater depths of the same soils covering uranium-mill tailings. The coefficients referred to diffusion in the total pore volume of the soils and are equivalent to values for the quantity, D/P, in the Generic Environmental Impact Statement on Uranium Milling prepared by the US Nuclear Regulatory Commission. Two soils were tested: a well-graded sand and an inorganic clay of low plasticity. For the flux evaluations, radon was collected by adsorption on charcoal following passive diffusion from the soil surface and also from air recirculating through an aluminum tent over the soil surface. An analysis of variance in the flux evaluations showed no significant difference between these two collection methods. Radon diffusion coefficients evaluated from field data were statistically indistinguishable, at the 95% confidence level, from those measured in the laboratory; however, the low precision of the field data prevented a sensitive validation of the laboratory measurements. From the field data, the coefficients were calculated to be 0.03 +- 0.03 cm 2 /s for the sand cover and 0.0036 +- 0.0004 cm 2 /s for the clay cover. The low precision in the coefficients evaluated from field data was attributed to high variation in radon flux with time and surface location at the field site

  1. Analysis and correction of gradient nonlinearity bias in apparent diffusion coefficient measurements.

    Science.gov (United States)

    Malyarenko, Dariya I; Ross, Brian D; Chenevert, Thomas L

    2014-03-01

    Gradient nonlinearity of MRI systems leads to spatially dependent b-values and consequently high non-uniformity errors (10-20%) in apparent diffusion coefficient (ADC) measurements over clinically relevant field-of-views. This work seeks practical correction procedure that effectively reduces observed ADC bias for media of arbitrary anisotropy in the fewest measurements. All-inclusive bias analysis considers spatial and time-domain cross-terms for diffusion and imaging gradients. The proposed correction is based on rotation of the gradient nonlinearity tensor into the diffusion gradient frame where spatial bias of b-matrix can be approximated by its Euclidean norm. Correction efficiency of the proposed procedure is numerically evaluated for a range of model diffusion tensor anisotropies and orientations. Spatial dependence of nonlinearity correction terms accounts for the bulk (75-95%) of ADC bias for FA = 0.3-0.9. Residual ADC non-uniformity errors are amplified for anisotropic diffusion. This approximation obviates need for full diffusion tensor measurement and diagonalization to derive a corrected ADC. Practical scenarios are outlined for implementation of the correction on clinical MRI systems. The proposed simplified correction algorithm appears sufficient to control ADC non-uniformity errors in clinical studies using three orthogonal diffusion measurements. The most efficient reduction of ADC bias for anisotropic medium is achieved with non-lab-based diffusion gradients. Copyright © 2013 Wiley Periodicals, Inc.

  2. Variability of non-Gaussian diffusion MRI and intravoxel incoherent motion (IVIM) measurements in the breast.

    Science.gov (United States)

    Iima, Mami; Kataoka, Masako; Kanao, Shotaro; Kawai, Makiko; Onishi, Natsuko; Koyasu, Sho; Murata, Katsutoshi; Ohashi, Akane; Sakaguchi, Rena; Togashi, Kaori

    2018-01-01

    We prospectively examined the variability of non-Gaussian diffusion magnetic resonance imaging (MRI) and intravoxel incoherent motion (IVIM) measurements with different numbers of b-values and excitations in normal breast tissue and breast lesions. Thirteen volunteers and fourteen patients with breast lesions (seven malignant, eight benign; one patient had bilateral lesions) were recruited in this prospective study (approved by the Internal Review Board). Diffusion-weighted MRI was performed with 16 b-values (0-2500 s/mm2 with one number of excitations [NEX]) and five b-values (0-2500 s/mm2, 3 NEX), using a 3T breast MRI. Intravoxel incoherent motion (flowing blood volume fraction [fIVIM] and pseudodiffusion coefficient [D*]) and non-Gaussian diffusion (theoretical apparent diffusion coefficient [ADC] at b value of 0 sec/mm2 [ADC0] and kurtosis [K]) parameters were estimated from IVIM and Kurtosis models using 16 b-values, and synthetic apparent diffusion coefficient (sADC) values were obtained from two key b-values. The variabilities between and within subjects and between different diffusion acquisition methods were estimated. There were no statistical differences in ADC0, K, or sADC values between the different b-values or NEX. A good agreement of diffusion parameters was observed between 16 b-values (one NEX), five b-values (one NEX), and five b-values (three NEX) in normal breast tissue or breast lesions. Insufficient agreement was observed for IVIM parameters. There were no statistical differences in the non-Gaussian diffusion MRI estimated values obtained from a different number of b-values or excitations in normal breast tissue or breast lesions. These data suggest that a limited MRI protocol using a few b-values might be relevant in a clinical setting for the estimation of non-Gaussian diffusion MRI parameters in normal breast tissue and breast lesions.

  3. Study of apparent diffusion coefficient value in the normal breastq

    International Nuclear Information System (INIS)

    Cai Shifeng

    2007-01-01

    Objective: To investigate the differences of apparent diffusion coefficient (ADC) value in normal breasts and to evaluate the correlation between ADC value and corresponding histology. Methods: Sixty-two normal breasts including 42 normal breasts of 42 patients with unilateral lesions and 20 normal breasts of 10 volunteers were studied. The ADC value of all 62 normal breasts were calculated when b value was given from 1000 to 0 s/mm 2 , 1000 to 500 s/mm 2 and 500 to 0 s/mm 2 . The MRI features of 60 normal breasts were classified into 3 types (dense, lobular-speckled, degenerative types) according to Wolf's classification and histology. Results: DWI and ADC images were different in 3 types of normal breasts because of different histologic structures. The mean ADC value of the dense type breasts was (1.70 ± 0.37) x 10 -3 mm 2 /s, the lobular-speckled type was (1.93 ± 0.46) x 10 -3 mm 2 /s and the degenerative type was (1.18 ± 0.65) x 10 -3 mm 2 /s (F=12.998, P=0.000). There were no significant differences between the dense type and the lobular-speckled type (F=2.167, P=0.147), but significant differences between the dense type and the degenerative type, the lobular-speckled type and the degenerate type (F=5.593 and 19.128; P=0.029 and 0.000). When b value decreased, the ADC value of the dense type and the lobular-speckled type increased correspondingly, but the degenerative type didn't increase apparently. Conclusion: ADC value was influenced by histologic structures in normal breasts and also was influenced by b value in the dense type and lobular-speckled type breasts. (authors)

  4. Spatial Mapping of Translational Diffusion Coefficients Using Diffusion Tensor Imaging: A Mathematical Description.

    Science.gov (United States)

    Shetty, Anil N; Chiang, Sharon; Maletic-Savatic, Mirjana; Kasprian, Gregor; Vannucci, Marina; Lee, Wesley

    2014-01-01

    In this article, we discuss the theoretical background for diffusion weighted imaging and diffusion tensor imaging. Molecular diffusion is a random process involving thermal Brownian motion. In biological tissues, the underlying microstructures restrict the diffusion of water molecules, making diffusion directionally dependent. Water diffusion in tissue is mathematically characterized by the diffusion tensor, the elements of which contain information about the magnitude and direction of diffusion and is a function of the coordinate system. Thus, it is possible to generate contrast in tissue based primarily on diffusion effects. Expressing diffusion in terms of the measured diffusion coefficient (eigenvalue) in any one direction can lead to errors. Nowhere is this more evident than in white matter, due to the preferential orientation of myelin fibers. The directional dependency is removed by diagonalization of the diffusion tensor, which then yields a set of three eigenvalues and eigenvectors, representing the magnitude and direction of the three orthogonal axes of the diffusion ellipsoid, respectively. For example, the eigenvalue corresponding to the eigenvector along the long axis of the fiber corresponds qualitatively to diffusion with least restriction. Determination of the principal values of the diffusion tensor and various anisotropic indices provides structural information. We review the use of diffusion measurements using the modified Stejskal-Tanner diffusion equation. The anisotropy is analyzed by decomposing the diffusion tensor based on symmetrical properties describing the geometry of diffusion tensor. We further describe diffusion tensor properties in visualizing fiber tract organization of the human brain.

  5. THE DETERMINATION OF DIFFUSION COEFFICIENT OF INVERT MATERIALS

    International Nuclear Information System (INIS)

    P. Heller and J. Wright

    2000-01-01

    The Engineered Barrier System (EBS) Testing Department is performing tests in the Department of Energy's Atlas Facility to evaluate the performance of various means for increasing the time for breakthrough of radionuclides from the waste package to the base of the invert. This includes testing various barriers in the invert as a means of increasing breakthrough time through the process of diffusion. A diffusion barrier may serve as an invert material for the emplacement drifts. The invert material may consist of crushed tuff from the repository excavation at Yucca Mountain or silica sand. The objective of this report is to determine the diffusion coefficient of the crushed tuff and silica sand invert materials specified by the EBS Testing Department. The laboratory derived information from the testing was used in the Nernst-Einstein equation (Jurinak et al. 1987, p. 626) to determine the diffusion coefficient of the invert material. This report transmits the results and describes the methodology and interpretation. The scope of this report is to determine the diffusion coefficients of the invert materials mentioned above using the centrifuge at UFA Ventures. Standard laboratory procedures, described in Section 2 of this report, were used. The diffusion coefficients are to be determined over a range of moisture contents. The report contains the diffusion coefficients calculated by the Nernst-Einstein equation (Jurinak et al. 1987, p. 626) that become a part of the Technical Database. Raw data is also included in the report, however this data does not become part of the Technical Database as per Section 3.23 of AP-SIII.3Q ''Submittal and Incorporation of Data to the Technical Data Management System''. A sieve analysis of the samples was not conducted as part of this report, but sieve analysis may be accomplished as part of other reports. Two samples of crushed tuff and two samples of silica sand were tested

  6. Flux-limited diffusion coefficients in reactor physics applications

    International Nuclear Information System (INIS)

    Pounders, J.; Rahnema, F.; Szilard, R.

    2007-01-01

    Flux-limited diffusion theory has been successfully applied to problems in radiative transfer and radiation hydrodynamics, but its relevance to reactor physics has not yet been explored. The current investigation compares the performance of a flux-limited diffusion coefficient against the traditionally defined transport cross section. A one-dimensional BWR benchmark problem is examined at both the assembly and full-core level with varying degrees of heterogeneity. (authors)

  7. D-BRAIN : Anatomically accurate simulated diffusion MRI brain data

    NARCIS (Netherlands)

    Perrone, Daniele; Jeurissen, Ben; Aelterman, Jan; Roine, Timo; Sijbers, Jan; Pizurica, Aleksandra; Leemans, Alexander; Philips, Wilfried

    2016-01-01

    Diffusion Weighted (DW) MRI allows for the non-invasive study of water diffusion inside living tissues. As such, it is useful for the investigation of human brain white matter (WM) connectivity in vivo through fiber tractography (FT) algorithms. Many DW-MRI tailored restoration techniques and FT

  8. Associations among q-space MRI, diffusion-weighted MRI and histopathological parameters in meningiomas

    Energy Technology Data Exchange (ETDEWEB)

    Fatima, Zareen; Motosugi, Utaroh; Ishigame, Keiichi; Araki, Tsutomu [University of Yamanashi, Department of Radiology, Chuo-shi, Yamanashi (Japan); Waqar, Ahmed Bilal [University of Yamanashi, Department of Molecular Pathology, Interdisciplinary Graduate School of Medicine and Engineering, Chuo-shi, Yamanashi (Japan); Hori, Masaaki [Juntendo University, Department of Radiology, School of Medicine, Tokyo (Japan); Oishi, Naoki; Katoh, Ryohei [University of Yamanashi, Department of Pathology, Chuo-shi, Yamanashi (Japan); Onodera, Toshiyuki; Yagi, Kazuo [Tokyo Metropolitan University, Department of Radiological Sciences, Graduate School of Human Health Sciences, Tokyo (Japan)

    2013-08-15

    The purposes of this MR-based study were to calculate q-space imaging (QSI)-derived mean displacement (MDP) in meningiomas, to evaluate the correlation of MDP values with apparent diffusion coefficient (ADC) and to investigate the relationships among these diffusion parameters, tumour cell count (TCC) and MIB-1 labelling index (LI). MRI, including QSI and conventional diffusion-weighted imaging (DWI), was performed in 44 meningioma patients (52 lesions). ADC and MDP maps were acquired from post-processing of the data. Quantitative analyses of these maps were performed by applying regions of interest. Pearson correlation coefficients were calculated for ADC and MDP in all lesions and for ADC and TCC, MDP and TCC, ADC and MIB-1 LI, and MDP and MIB-1 LI in 17 patients who underwent subsequent surgery. ADC and MDP values were found to have a strong correlation: r = 0.78 (P = <0.0001). Both ADC and MDP values had a significant negative association with TCC: r = -0.53 (p = 0.02) and -0.48 (P = 0.04), respectively. MIB-1 LI was not, however, found to have a significant association with these diffusion parameters. In meningiomas, both ADC and MDP may be representative of cell density. (orig.)

  9. Associations among q-space MRI, diffusion-weighted MRI and histopathological parameters in meningiomas

    International Nuclear Information System (INIS)

    Fatima, Zareen; Motosugi, Utaroh; Ishigame, Keiichi; Araki, Tsutomu; Waqar, Ahmed Bilal; Hori, Masaaki; Oishi, Naoki; Katoh, Ryohei; Onodera, Toshiyuki; Yagi, Kazuo

    2013-01-01

    The purposes of this MR-based study were to calculate q-space imaging (QSI)-derived mean displacement (MDP) in meningiomas, to evaluate the correlation of MDP values with apparent diffusion coefficient (ADC) and to investigate the relationships among these diffusion parameters, tumour cell count (TCC) and MIB-1 labelling index (LI). MRI, including QSI and conventional diffusion-weighted imaging (DWI), was performed in 44 meningioma patients (52 lesions). ADC and MDP maps were acquired from post-processing of the data. Quantitative analyses of these maps were performed by applying regions of interest. Pearson correlation coefficients were calculated for ADC and MDP in all lesions and for ADC and TCC, MDP and TCC, ADC and MIB-1 LI, and MDP and MIB-1 LI in 17 patients who underwent subsequent surgery. ADC and MDP values were found to have a strong correlation: r = 0.78 (P = <0.0001). Both ADC and MDP values had a significant negative association with TCC: r = -0.53 (p = 0.02) and -0.48 (P = 0.04), respectively. MIB-1 LI was not, however, found to have a significant association with these diffusion parameters. In meningiomas, both ADC and MDP may be representative of cell density. (orig.)

  10. Oxygen transport in waterlogged soils, Part II. Diffusion coefficients

    International Nuclear Information System (INIS)

    Obando Moncayo, F.H.

    2004-01-01

    Several equations are available for Oxygen Transport in Waterlogged Soils and have been used for soils and plants. All of them are some form of first Fick's law as given by dQ = - DA(dc/dx)/dt. This equation illustrates some important aspects of aeration in waterlogged soils; first, D is a property of the medium and the gas, and is affected by temperature T. Likewise, the amount of diffusing substance dQ in dt is a direct function of the cross sectional area A and inversely proportional to the distance x. In fact, increasing the water content of air-dry soil, drastically decreases A and creates a further resistance for the flow of oxygen through water films around root plants, soil micro organisms and soil aggregates. The solid phase is also limiting the cross-section of surface of the free gaseous diffusion and the length and tortuosity of diffusion path in soil. In most of cases, soil gas porosity and tortuosity of soil voids are expressed in the equations of diffusion as a broad 'diffusion coefficient' (apparent coefficient diffusion). The process of soil respiration is complicated, involves many parameters, and is difficult to realistically quantify. With regard to the oxygen supply, it is convenient to distinguish macro and micro models, and hence, the flux of oxygen is assumed to have two steps. The first step is related to oxygen diffusion from the atmosphere and the air-filled porosity. The second step is related to the oxygen diffusion through water-films in and around plant roots, soil micro organisms and aggregates. Because of these models we obtain coefficients of macro or micro diffusion, rates of macro or micro diffusion, etc. In the macro diffusion process oxygen is transferred in the soil profile, mainly from the soil surface to a certain depth of the root zone, while micro diffusion deals with the flux over very short distances. Both processes, macro and micro diffusion are highly influenced by soil water content. Of course, if water is added to

  11. Diffusion coefficients in 4-component mixture expressed explicitly in terms of binary diffusion coefficients and mole fractions

    International Nuclear Information System (INIS)

    Furuta, Hiroshi; Yamamoto, Ichiro

    1996-01-01

    Diffusion coefficients in 4-component mixture D ij (4) were expressed explicitly in terms of binary diffusion coefficients and mole fractions by solving a ratio of determinants defined by Hirschfelder et al. The explicit expressions of D ij (4) were divided into two terms, a term due to the i-j pairs of attention and a term common to all the pairs out of the 4 components. The two terms of D ij (4) had extended structures similar to corresponding those of D ij (3) respectively. (author)

  12. Clinical utility of apparent diffusion coefficient values obtained using high b-value when diagnosing prostate cancer using 3 tesla MRI: comparison between ultra-high b-value (2000 s/mm²) and standard high b-value (1000 s/mm²).

    Science.gov (United States)

    Kitajima, Kazuhiro; Takahashi, Satoru; Ueno, Yoshiko; Yoshikawa, Takeshi; Ohno, Yoshiharu; Obara, Makoto; Miyake, Hideaki; Fujisawa, Masato; Sugimura, Kazuro

    2012-07-01

    To determine whether the apparent diffusion coefficient (ADC) obtained using b = 2000 s/mm(2) upon 3 Tesla (T) diffusion-weighted MRI is superior to b = 1000 s/mm(2) for discriminating malignant from normal prostate tissue and predicting the aggressiveness of prostate cancer, using histopathological findings of radical prostatectomy as a reference. Eighty prostate cancer patients underwent preoperative 3T MRI including diffusion weighted imaging with b-values of 0, 1000, and 2000 s/mm(2) . ADCs were measured for malignant lesions and normal sites on three sets of ADC maps calculated with monoexponential fitting between b = 0 and 1000, 0 and 2000, and 1000 and 2000, respectively. The relationship between the ADC and Gleason score was evaluated. The areas under the ROC curves for b = 0,1000, b = 0,2000, and b = 1000,2000 were 0.896, 0.937, and 0.857, respectively, in the peripheral zone (PZ) and 0.877, 0.889, and 0.731, respectively, in the transition zone (TZ). The difference between b = 0,1000 and b = 0,2000 was significant in PZ (P = 0.033), but not in TZ (P = 0.84). Weak but significant negative correlations were identified between ADCs and Gleason score in both PZ and TZ cancer at b = 0,1000 and b = 0,2000 (r = -0.323 to -0.341). For 3T MRI, ADCs using b = 0,2000 are more accurate than b = 0,1000 for diagnosing PZ cancer, and as accurate for TZ cancer. Copyright © 2012 Wiley Periodicals, Inc.

  13. Estimating the Diffusion Coefficients of Sugars Using Diffusion Experiments in Agar-Gel and Computer Simulations.

    Science.gov (United States)

    Miyamoto, Shuichi; Atsuyama, Kenji; Ekino, Keisuke; Shin, Takashi

    2018-01-01

    The isolation of useful microbes is one of the traditional approaches for the lead generation in drug discovery. As an effective technique for microbe isolation, we recently developed a multidimensional diffusion-based gradient culture system of microbes. In order to enhance the utility of the system, it is favorable to have diffusion coefficients of nutrients such as sugars in the culture medium beforehand. We have, therefore, built a simple and convenient experimental system that uses agar-gel to observe diffusion. Next, we performed computer simulations-based on random-walk concepts-of the experimental diffusion system and derived correlation formulas that relate observable diffusion data to diffusion coefficients. Finally, we applied these correlation formulas to our experimentally-determined diffusion data to estimate the diffusion coefficients of sugars. Our values for these coefficients agree reasonably well with values published in the literature. The effectiveness of our simple technique, which has elucidated the diffusion coefficients of some molecules which are rarely reported (e.g., galactose, trehalose, and glycerol) is demonstrated by the strong correspondence between the literature values and those obtained in our experiments.

  14. Diffusion-weighted MRI in acute cerebral stroke

    Energy Technology Data Exchange (ETDEWEB)

    Takayama, Hideichi; Kobayashi, Masahito; Suga, Sadao; Kawase, Takeshi; Nagasawa, Masakazu; Sadanaga, Humiko; Okamura, Miyuki; Kanai, Yoshihiro; Mihara, Ban [Mihara Memorial Hospital, Isezaki, Gunma (Japan)

    1999-03-01

    Diffusion-weighted MRI has been demonstrated to be valuable in the assessment of cerebral stroke. Recent advance in MR systems of hardware with larger maximum gradient amplitude and faster imaging strategies, such as EPI, has made it possible to acquire whole brain diffusion-weighted imaging (DWI) in less that one minute. The purposes of this study are to evaluate clinical usefulness of DWI and to clarify pitfalls in the diagnosis of acute cerebral stroke. Seventeen patients with 18 ischemic lesions were studied. DWI were taken with 1.5 Tesla MRI (Magnetom Vision, Siemens, Germany) using EPI sequence. Fifteen lesions out of them (3 in cerebral cortex, 9 in basal ganglia/deep white matter and 3 in cerebellum) were studied serially at various times up to 147 days. Acute cerebral infarction was seen clearly as an area of hyperintensity with DWI and as hypointensity in apparent diffusion coefficient (ADC) maps which are indicative of decreased diffusion. DWI detected areas of hyperintense acute infarcts, as early as 2.5 hours after onset, which were not visualized on T{sub 2}-weighted image (T2WI). The lesion of cerebral infarction became isointense in ADC maps at 14-28 days after onset, whereas with DWI it became isointense at about 2 months. Because ADC changed earlier than DWI, ADC maps were useful for differentiate acute from nonacute lesion in cases of recurrent stroke within a short period. In a patient with transient global amnesia for 7 hours, DWI did not show any lesion at 8 hours. In terms of cerebral hemorrhage, lesions were seen as area of hyperintensity in DWI at 3 days and were not distinguishable from that of infarct. Despite limitations in the diagnosis of transient ischemia and cerebral hemorrhage, DWI is a useful technique for early detection of cerebral infarction, especially within the first 6 hours after stroke onset. (author)

  15. Diffusion-weighted MRI in acute cerebral stroke

    International Nuclear Information System (INIS)

    Takayama, Hideichi; Kobayashi, Masahito; Suga, Sadao; Kawase, Takeshi; Nagasawa, Masakazu; Sadanaga, Humiko; Okamura, Miyuki; Kanai, Yoshihiro; Mihara, Ban

    1999-01-01

    Diffusion-weighted MRI has been demonstrated to be valuable in the assessment of cerebral stroke. Recent advance in MR systems of hardware with larger maximum gradient amplitude and faster imaging strategies, such as EPI, has made it possible to acquire whole brain diffusion-weighted imaging (DWI) in less that one minute. The purposes of this study are to evaluate clinical usefulness of DWI and to clarify pitfalls in the diagnosis of acute cerebral stroke. Seventeen patients with 18 ischemic lesions were studied. DWI were taken with 1.5 Tesla MRI (Magnetom Vision, Siemens, Germany) using EPI sequence. Fifteen lesions out of them (3 in cerebral cortex, 9 in basal ganglia/deep white matter and 3 in cerebellum) were studied serially at various times up to 147 days. Acute cerebral infarction was seen clearly as an area of hyperintensity with DWI and as hypointensity in apparent diffusion coefficient (ADC) maps which are indicative of decreased diffusion. DWI detected areas of hyperintense acute infarcts, as early as 2.5 hours after onset, which were not visualized on T 2 -weighted image (T2WI). The lesion of cerebral infarction became isointense in ADC maps at 14-28 days after onset, whereas with DWI it became isointense at about 2 months. Because ADC changed earlier than DWI, ADC maps were useful for differentiate acute from nonacute lesion in cases of recurrent stroke within a short period. In a patient with transient global amnesia for 7 hours, DWI did not show any lesion at 8 hours. In terms of cerebral hemorrhage, lesions were seen as area of hyperintensity in DWI at 3 days and were not distinguishable from that of infarct. Despite limitations in the diagnosis of transient ischemia and cerebral hemorrhage, DWI is a useful technique for early detection of cerebral infarction, especially within the first 6 hours after stroke onset. (author)

  16. Determination of the chloride diffusion coefficient in blended cement mortars

    NARCIS (Netherlands)

    Elfmarkova, V.; Spiesz, P.R.; Brouwers, H.J.H.

    2015-01-01

    The rapid chloride migration test (RCM) is a commonly used accelerated test for the determination of the chloride diffusion coefficient in concrete. Nevertheless, the initial development and further experience with the RCM test concern mainly the ordinary Portland cement system. Therefore, the

  17. Redox Couples with Unequal Diffusion Coefficients: Effect on Redox Cycling

    NARCIS (Netherlands)

    Mampallil Augustine, Dileep; Mathwig, Klaus; Kang, Shuo; Lemay, Serge Joseph Guy

    2013-01-01

    Redox cycling between two electrodes separated by a narrow gap allows dramatic amplification of the faradaic current. Unlike conventional electrochemistry at a single electrode, however, the mass-transport-limited current is controlled by the diffusion coefficient of both the reduced and oxidized

  18. Plateau diffusion coefficient for arbitrary flux surface geometry

    International Nuclear Information System (INIS)

    Meier, H.K.; Hirshman, S.P.; Sigmar, D.J.; Lao, L.L.

    1981-03-01

    A relatively simple but accurate representation has been developed for magnetic flux surfaces; it is valid for finite β and it describes configurations with both ellipticity and D-shape. This representation has been applied to the computation of the diffusion coefficient in the plateau regime

  19. Pressure drop coefficient of laminar Newtonian flow in axisymmetric diffusers

    International Nuclear Information System (INIS)

    Rosa, S.; Pinho, F.T.

    2006-01-01

    The laminar flow of Newtonian fluids in axisymmetric diffusers has been numerically investigated to evaluate the pressure-loss coefficient as a function of Reynolds number, diffusion angle and expansion ratio. The numerical simulations were carried out with a finite-volume based code using non-orthogonal collocated grids and second order accurate differencing schemes to discretize all terms of the transport equations. The calculations were carried out for Reynolds numbers between 2 and 200, diffusion angles from 0 deg. to 90 deg. and expansion ratios of 1.5 and 2 and the data are presented in tabular form and as correlations. A simplified 1D theoretical analysis helped explain the various contributions to the loss coefficient and its difference relative to the reversible pressure variation due to differences between the actual and fully developed friction losses, distortions of the velocity profiles and pressure non-uniformity upstream and downstream of the expansion section

  20. Pressure drop coefficient of laminar Newtonian flow in axisymmetric diffusers

    Energy Technology Data Exchange (ETDEWEB)

    Rosa, S. [Escola Superior de Tecnologia e Gestao, Instituto Politecnico, Campus de Santa Apolonia, 5301-857 Braganca (Portugal)]. E-mail: srosa@ipb.pt; Pinho, F.T. [Centro de Estudos de Fenomenos de Transporte, DEM, Universidade do Minho, Campus de Azurem, 4800-058 Guimaraes (Portugal)]. E-mail: fpinho@fe.up.pt

    2006-04-15

    The laminar flow of Newtonian fluids in axisymmetric diffusers has been numerically investigated to evaluate the pressure-loss coefficient as a function of Reynolds number, diffusion angle and expansion ratio. The numerical simulations were carried out with a finite-volume based code using non-orthogonal collocated grids and second order accurate differencing schemes to discretize all terms of the transport equations. The calculations were carried out for Reynolds numbers between 2 and 200, diffusion angles from 0 deg. to 90 deg. and expansion ratios of 1.5 and 2 and the data are presented in tabular form and as correlations. A simplified 1D theoretical analysis helped explain the various contributions to the loss coefficient and its difference relative to the reversible pressure variation due to differences between the actual and fully developed friction losses, distortions of the velocity profiles and pressure non-uniformity upstream and downstream of the expansion section.

  1. Effective hydrogen diffusion coefficient for solidifying aluminium alloys

    International Nuclear Information System (INIS)

    Felberbaum, M.; Landry-Desy, E.; Weber, L.; Rappaz, M.

    2011-01-01

    An effective hydrogen diffusion coefficient has been calculated for two solidifying Al - 4.5 wt.% Cu and Al - 10 wt.% Cu alloys as a function of the volume fraction of solid. For this purpose, in situ X-ray tomography was performed on these alloys. For each volume fraction of solid between 0.6 and 0.9, a representative volume element of the microstructure was extracted. Solid and liquid voxels were assimilated to solid and liquid nodes in order to solve the hydrogen diffusion equation based on the chemical potential and using a finite volume formulation. An effective hydrogen diffusion coefficient based on the volume fraction of solid only could be deduced from the results of the numerical model at steady state. The results are compared with various effective medium theories.

  2. Variable Eddington factors and flux-limiting diffusion coefficients

    International Nuclear Information System (INIS)

    Whalen, P.P.

    1982-01-01

    Variable Eddington factors and flux limiting diffusion coefficients arise in two common techniques of closing the moment equations of transport. The first two moment equations of the full transport equation are still frequently used to solve many problems of radiative or particle transport. An approximate analysis, developed by Levermore, exhibits the relation between the coefficients of the two different techniques. This analysis is described and then used to test the validity of several commonly used flux limiters and Eddington factors. All of the ad-hoc flux limiters have limited validity. All of the variable Eddington factors derived from some underlying description of the angular distribution function are generally valid. The use of coefficients from Minerbo's elegant maximum entropy Eddington factor analysis is suggested for use in either flux limited diffusion or variable Eddington factor equations

  3. Correlation Between Minimum Apparent Diffusion Coefficient (ADCmin) and Tumor Cellularity: A Meta-analysis.

    Science.gov (United States)

    Surov, Alexey; Meyer, Hans Jonas; Wienke, Andreas

    2017-07-01

    Diffusion-weighted imaging (DWI) is a magnetic resonance imaging (MRI) technique based on measure of water diffusion that can provide information about tissue microstructure, especially about cell count. Increase of cell density induces restriction of water diffusion and decreases apparent diffusion coefficient (ADC). ADC can be divided into three sub-parameters: ADC minimum or ADC min , mean ADC or ADC mean and ADC maximum or ADC max Some studies have suggested that ADC min shows stronger correlations with cell count in comparison to other ADC fractions and may be used as a parameter for estimation of tumor cellularity. The aim of the present meta-analysis was to summarize correlation coefficients between ADC min and cellularity in different tumors based on large patient data. For this analysis, MEDLINE database was screened for associations between ADC and cell count in different tumors up to September 2016. For this work, only data regarding ADC min were included. Overall, 12 publications with 317 patients were identified. Spearman's correlation coefficient was used to analyze associations between ADC min and cellularity. The reported Pearson correlation coefficients in some publications were converted into Spearman correlation coefficients. The pooled correlation coefficient for all included studies was ρ=-0.59 (95% confidence interval (CI)=-0.72 to -0.45), heterogeneity Tau 2 =0.04 (pcorrelated moderately with tumor cellularity. The calculated correlation coefficient is not stronger in comparison to the reported coefficient for ADC mean and, therefore, ADC min does not represent a better means to reflect cellularity. Copyright© 2017, International Institute of Anticancer Research (Dr. George J. Delinasios), All rights reserved.

  4. Apparent Diffusion Coefficient and Dynamic Contrast-Enhanced Magnetic Resonance Imaging in Pancreatic Cancer: Characteristics and Correlation With Histopathologic Parameters.

    Science.gov (United States)

    Ma, Wanling; Li, Na; Zhao, Weiwei; Ren, Jing; Wei, Mengqi; Yang, Yong; Wang, Yingmei; Fu, Xin; Zhang, Zhuoli; Larson, Andrew C; Huan, Yi

    2016-01-01

    To clarify diffusion and perfusion abnormalities and evaluate correlation between apparent diffusion coefficient (ADC), MR perfusion and histopathologic parameters of pancreatic cancer (PC). Eighteen patients with PC underwent diffusion-weighted imaging and dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI). Parameters of DCE-MRI and ADC of cancer and non-cancerous tissue were compared. Correlation between the rate constant that represents transfer of contrast agent from the arterial blood into the extravascular extracellular space (K, volume of the extravascular extracellular space per unit volume of tissue (Ve), and ADC of PC and histopathologic parameters were analyzed. The rate constant that represents transfer of contrast agent from the extravascular extracellular space into blood plasma, K, tissue volume fraction occupied by vascular space, and ADC of PC were significantly lower than nontumoral pancreases. Ve of PC was significantly higher than that of nontumoral pancreas. Apparent diffusion coefficient and K values of PC were negatively correlated to fibrosis content and fibroblast activation protein staining score. Fibrosis content was positively correlated to Ve. Apparent diffusion coefficient values and parameters of DCE-MRI can differentiate PC from nontumoral pancreases. There are correlations between ADC, K, Ve, and fibrosis content of PC. Fibroblast activation protein staining score of PC is negatively correlated to ADC and K. Apparent diffusion coefficient, K, and Ve may be feasible to predict prognosis of PC.

  5. Regularized spherical polar fourier diffusion MRI with optimal dictionary learning.

    Science.gov (United States)

    Cheng, Jian; Jiang, Tianzi; Deriche, Rachid; Shen, Dinggang; Yap, Pew-Thian

    2013-01-01

    Compressed Sensing (CS) takes advantage of signal sparsity or compressibility and allows superb signal reconstruction from relatively few measurements. Based on CS theory, a suitable dictionary for sparse representation of the signal is required. In diffusion MRI (dMRI), CS methods proposed for reconstruction of diffusion-weighted signal and the Ensemble Average Propagator (EAP) utilize two kinds of Dictionary Learning (DL) methods: 1) Discrete Representation DL (DR-DL), and 2) Continuous Representation DL (CR-DL). DR-DL is susceptible to numerical inaccuracy owing to interpolation and regridding errors in a discretized q-space. In this paper, we propose a novel CR-DL approach, called Dictionary Learning - Spherical Polar Fourier Imaging (DL-SPFI) for effective compressed-sensing reconstruction of the q-space diffusion-weighted signal and the EAP. In DL-SPFI, a dictionary that sparsifies the signal is learned from the space of continuous Gaussian diffusion signals. The learned dictionary is then adaptively applied to different voxels using a weighted LASSO framework for robust signal reconstruction. Compared with the start-of-the-art CR-DL and DR-DL methods proposed by Merlet et al. and Bilgic et al., respectively, our work offers the following advantages. First, the learned dictionary is proved to be optimal for Gaussian diffusion signals. Second, to our knowledge, this is the first work to learn a voxel-adaptive dictionary. The importance of the adaptive dictionary in EAP reconstruction will be demonstrated theoretically and empirically. Third, optimization in DL-SPFI is only performed in a small subspace resided by the SPF coefficients, as opposed to the q-space approach utilized by Merlet et al. We experimentally evaluated DL-SPFI with respect to L1-norm regularized SPFI (L1-SPFI), which uses the original SPF basis, and the DR-DL method proposed by Bilgic et al. The experiment results on synthetic and real data indicate that the learned dictionary produces

  6. Diffusion coefficient of hydrogen in niobium and tantalum

    International Nuclear Information System (INIS)

    Vargas, P.; Miranda, L.; Lagos, M.

    1988-08-01

    We show that the current data on hydrogen diffusion in Tantalum between 15K and 550K and in Niobium between 135K and 400K can be quantitatively explained by the small polaron theory. The experimental data can be understood assuming ground-state to ground-state tunneling between interstitial sites with tetrahedral symmetry plus an activated contribution due to tunneling between excited states having octahedral symmetry. The break of the diffusivity curve at T approx. = 250K follows naturally. It evidences the transition between the tetrahedral and octahedral hopping. For Ta the second break of the diffusivity curve at T approx. = 20K indicated the recovering of the ground-state hopping with tetrahedral symmetry. Below T approx. = 10K for Ta and T approx. = 7K for Nb the diffusion coefficient becomes independent of T. (author). 17 refs, 3 figs, 1 tab

  7. Diffusion-weighted MRI in Crohn's disease: Current status and recommendations

    OpenAIRE

    Dohan, A.; Taylor, S.; Hoeffel, C.; Barret, M.; Allez, M.; Dautry, R.; Zappa, M.; Savoye-Collet, C.; Dray, X.; Boudiaf, M.; Reinhold, C.; Soyer, P.

    2016-01-01

    Over the past years, technological improvements and refinements in magnetic resonance imaging (MRI) hardware have made high-quality diffusion-weighted imaging (DWI) routinely possible for the bowel. DWI is promising for the detection and characterization of lesions in Crohn's disease (CD) and has been advocated as an alternative to intravenous gadolinium-based contrast agents. Furthermore, quantification using the apparent diffusion coefficient may have value as a biomarker of CD activity and...

  8. Intercomparison of diffusion coefficient derived from the through-diffusion experiment using different numerical methods

    International Nuclear Information System (INIS)

    Chih-Lung Chen; Institute of Nuclear Energy Research, Taoyuan, Taiwan; Tsing-Hai Wang; Shi-Ping Teng; Ching-Hor Lee

    2014-01-01

    Diffusion is a dominant mechanism regulating the transport of released nuclides. The through-diffusion method is typically applied to determine the diffusion coefficients (D). Depending on the design of the experiment, the concentrations in the source term [i.e., inlet reservoir (IR)] or the end term [i.e., outlet reservoir (OR)] can be fixed or vary. The combinations involve four distinct models (i.e., the CC-CC model, CC-VC model, VC-CC model, and the VC-VC model). Studies discussing the VC-CC model are scant. An analytical method considering the decay effect is required to accurately interpret the radioactive nuclide diffusion experiment results. Therefore, we developed a CC-CC model and a CC-VC model with a decay effect and the simplified formulas of these two models to determine the diffusion coefficient (i.e., the CC-CC method and CC-VC method). We also proposed two simplified methods using the VC-VC model to determine the diffusion coefficient straightforwardly based upon the concentration variation in IR and OR. More importantly, the best advantage of proposed method over others is that one can derive three diffusion coefficients based on one run of experiment. In addition, applying our CC-VC method to those data reported from Radiochemica Acta 96:111-117, 2008; and J Contam Hydrol 35:55-65, 1998, derived comparable diffusion coefficient lying in the identical order of magnitude. Furthermore, we proposed a formula to determine the conceptual critical time (Tc), which is particularly beneficial for the selection of using CC-VC or VC-VC method. Based on our proposed method, it becomes possible to calculate diffusion coefficient from a through-diffusion experiment in a shorter period of time. (author)

  9. Focal status epilepticus: follow-up by perfusion- and diffusion MRI

    International Nuclear Information System (INIS)

    El-Koussy, M.; Loevblad, K.O.; Kiefer, C.; Schroth, G.; Mathis, J.; Stepper, F.

    2002-01-01

    Diffusion-weighted MRI demonstrated bright right temporoparietal cortex, right hippocampus, and left cerebellum in a 63-year-old female suffering a focal convulsive status epilepticus. Hyperperfusion was noted in the right temporoparietal region. Two days later, a tendency to normalization of most of the diffusion and perfusion changes was noted, apart from the right hippocampus which became brighter on diffusion- and T2-weighted images. On the tenth day the apparent diffusion coefficient was slightly elevated, getting brighter on T2-weighted images with suspected mild post-contrast enhancement. We postulate that the discharging right hippocampus suffered cytotoxic edema, which later progressed to cell damage. (orig.)

  10. Focal status epilepticus: follow-up by perfusion- and diffusion MRI

    Energy Technology Data Exchange (ETDEWEB)

    El-Koussy, M; Loevblad, K O; Kiefer, C; Schroth, G [Department of Neuroradiology, University of Bern, Inselspital (Switzerland); Mathis, J; Stepper, F [Department of Neurology, University of Bern, Inselspital (Switzerland)

    2002-03-01

    Diffusion-weighted MRI demonstrated bright right temporoparietal cortex, right hippocampus, and left cerebellum in a 63-year-old female suffering a focal convulsive status epilepticus. Hyperperfusion was noted in the right temporoparietal region. Two days later, a tendency to normalization of most of the diffusion and perfusion changes was noted, apart from the right hippocampus which became brighter on diffusion- and T2-weighted images. On the tenth day the apparent diffusion coefficient was slightly elevated, getting brighter on T2-weighted images with suspected mild post-contrast enhancement. We postulate that the discharging right hippocampus suffered cytotoxic edema, which later progressed to cell damage. (orig.)

  11. Diffusion weighted imaging and estimation of prognosis using apparent diffusion coefficient measurements in ischemic stroke

    Energy Technology Data Exchange (ETDEWEB)

    Gonen, Korcan Aysun, E-mail: aysunbalc@yahoo.com [Department of Radiology, State Hospital, Eski Cami district, Hastane street, N:1, 59300, Tekirdag (Turkey); Simsek, Mehmet Masum, E-mail: radyoloji@haydapasanumune.gov.tr [Department of Radiology, Haydarpasa Numune Training and Research Hospital, Tibbiye street, Uskudar 34200, Istanbul (Turkey)

    2010-11-15

    Objective: Estimation of the prognosis of infarction by using diffusion weighted imaging (DWI) and quantitative apparent diffusion coefficient (ADC) measurements. Methods: 23 patients having acute stroke symptoms with verified infarction in magnetic resonance imaging (MRI) were included in this study. Their MRI studies were performed between 6 and 12 h after the onset of their symptoms and were repeated on the fifth day. The infarction volumes were calculated by using DWI and the patients were divided into two groups as the ones having an expansion in the infarction area (group 1, n = 16) and the others having no expansion in the infarction area (group 2, n = 7). Quantitative ADC values were estimated. The groups were compared in terms of the ADC values on ADC maps obtained from DWI, performed during the between 6 and 12 h from the onset of the symptoms, referring to the core of the infarction (ADC{sub IC}), ischemic penumbra (ADC{sub P}) and the nonischemic parenchymal tissue (ADC{sub N}). P values < 0.05 were accepted to be statistically significant. Results: During the between 6 and 12 h mean infarction volume calculated by DWI was 23.3 cm{sup 3} for group 1 patients (ranging from 1.1 to 68.6) and this was found to be 40.3 cm{sup 3} (ranging from 1.8 to 91.5) on the fifth day. For the group 2 patients these values were found to be 42.1 cm{sup 3} (ranging from 1 to 94.7) and 41.9 (ranging from 1 to 94.7) for the same intervals respectively. A significant statistical result was failed to be demonstrated between the mean ADC{sub IC} and ADC{sub N} values (p = 0.350 and p = 0.229 respectively). However the comparison of the ADC{sub P} values between the groups was found to be highly significant (p < 0.001). When the differences between the ADC{sub P} and ADC{sub IC} and ADC{sub N} and ADC{sub P} were compared the results proved to be statistically significant (p = 0.038 and p < 0.001 respectively). Conclusions: We believe that ADC results that would be obtained from

  12. Diffusion weighted imaging and estimation of prognosis using apparent diffusion coefficient measurements in ischemic stroke

    International Nuclear Information System (INIS)

    Gonen, Korcan Aysun; Simsek, Mehmet Masum

    2010-01-01

    Objective: Estimation of the prognosis of infarction by using diffusion weighted imaging (DWI) and quantitative apparent diffusion coefficient (ADC) measurements. Methods: 23 patients having acute stroke symptoms with verified infarction in magnetic resonance imaging (MRI) were included in this study. Their MRI studies were performed between 6 and 12 h after the onset of their symptoms and were repeated on the fifth day. The infarction volumes were calculated by using DWI and the patients were divided into two groups as the ones having an expansion in the infarction area (group 1, n = 16) and the others having no expansion in the infarction area (group 2, n = 7). Quantitative ADC values were estimated. The groups were compared in terms of the ADC values on ADC maps obtained from DWI, performed during the between 6 and 12 h from the onset of the symptoms, referring to the core of the infarction (ADC IC ), ischemic penumbra (ADC P ) and the nonischemic parenchymal tissue (ADC N ). P values 3 for group 1 patients (ranging from 1.1 to 68.6) and this was found to be 40.3 cm 3 (ranging from 1.8 to 91.5) on the fifth day. For the group 2 patients these values were found to be 42.1 cm 3 (ranging from 1 to 94.7) and 41.9 (ranging from 1 to 94.7) for the same intervals respectively. A significant statistical result was failed to be demonstrated between the mean ADC IC and ADC N values (p = 0.350 and p = 0.229 respectively). However the comparison of the ADC P values between the groups was found to be highly significant (p P and ADC IC and ADC N and ADC P were compared the results proved to be statistically significant (p = 0.038 and p < 0.001 respectively). Conclusions: We believe that ADC results that would be obtained from the core and the penumbra of the infarction area will be beneficial in the estimation of the infarction prognosis and in the planning of a treatment protocol.

  13. Diffusion weighted MRI in intrahepatic bile duct adenoma arising from the cirrhotic liver

    Energy Technology Data Exchange (ETDEWEB)

    An, Chansik [Research Institute of Radiological Science, Severance Hospital, Yonsei University College of Medicine, Seoul (Korea, Republic of); Park, Sumi; Choi, Yoon Jung [National Health Insurance Corporation Ilsan Hospital, Goyang (Korea, Republic of)

    2013-10-15

    A 64-year-old male patient with liver cirrhosis underwent a CT study for hepatocellular carcinoma surveillance, which demonstrated a 1.4-cm hypervascular subcapsular tumor in the liver. On gadoxetic acid-enhanced MRI, the tumor showed brisk arterial enhancement and persistent hyperenhancement in the portal phase, but hypointensity in the hepatobiliary phase. On diffusion-weighted MRI, the tumor showed an apparent diffusion coefficient twofold greater than that of the background liver parenchyma, which suggested that the lesion was benign. The histologic diagnosis was intrahepatic bile duct adenoma with alcoholic liver cirrhosis.

  14. Diffusion-weighted MRI in intrahepatic bile duct adenoma arising from the cirrhotic liver.

    Science.gov (United States)

    An, Chansik; Park, Sumi; Choi, Yoon Jung

    2013-01-01

    A 64-year-old male patient with liver cirrhosis underwent a CT study for hepatocellular carcinoma surveillance, which demonstrated a 1.4-cm hypervascular subcapsular tumor in the liver. On gadoxetic acid-enhanced MRI, the tumor showed brisk arterial enhancement and persistent hyperenhancement in the portal phase, but hypointensity in the hepatobiliary phase. On diffusion-weighted MRI, the tumor showed an apparent diffusion coefficient twofold greater than that of the background liver parenchyma, which suggested that the lesion was benign. The histologic diagnosis was intrahepatic bile duct adenoma with alcoholic liver cirrhosis.

  15. Solubility and diffusion coefficient of oxygen in silicon

    International Nuclear Information System (INIS)

    Itoh, Yoshiko; Nozaki, Tadashi

    1985-01-01

    The solubility and diffusion coefficient of oxygen in silicon between 1000 0 C and 1375 0 C were examined by charged particle activation analysis with the 16 O( 3 He,p) 18 F reaction, in which oxygen was activated with an equal probability over the depth of up to 250μm by a specially devised apparatus. Silicon wafers of known histories were heated in oxygen or argon for 12 to 473 hours, and the resultant oxygen depth profiles were determined by the activation, subsequent stepwise etching and 18 F activity measurement. The solubility thus obtained is given as 9.3 x 10 21 exp[-27.6kcal mol -1 /RT] at.cm -3 ; the diffusion coefficient has been found to be approximated as 3.2 exp[-67.1kcal mol -1 /RT] cm 2 s -1 over 1150 0 C, under which the apparent activation energy seems to decrease with decrease of temperature. (author)

  16. Diffusion properties of conventional and calcium-sensitive MRI contrast agents in the rat cerebral cortex.

    Science.gov (United States)

    Hagberg, Gisela E; Mamedov, Ilgar; Power, Anthony; Beyerlein, Michael; Merkle, Hellmut; Kiselev, Valerij G; Dhingra, Kirti; Kubìček, Vojtĕch; Angelovski, Goran; Logothetis, Nikos K

    2014-01-01

    Calcium-sensitive MRI contrast agents can only yield quantitative results if the agent concentration in the tissue is known. The agent concentration could be determined by diffusion modeling, if relevant parameters were available. We have established an MRI-based method capable of determining diffusion properties of conventional and calcium-sensitive agents. Simulations and experiments demonstrate that the method is applicable both for conventional contrast agents with a fixed relaxivity value and for calcium-sensitive contrast agents. The full pharmacokinetic time-course of gadolinium concentration estimates was observed by MRI before, during and after intracerebral administration of the agent, and the effective diffusion coefficient D* was determined by voxel-wise fitting of the solution to the diffusion equation. The method yielded whole brain coverage with a high spatial and temporal sampling. The use of two types of MRI sequences for sampling of the diffusion time courses was investigated: Look-Locker-based quantitative T(1) mapping, and T(1) -weighted MRI. The observation times of the proposed MRI method is long (up to 20 h) and consequently the diffusion distances covered are also long (2-4 mm). Despite this difference, the D* values in vivo were in agreement with previous findings using optical measurement techniques, based on observation times of a few minutes. The effective diffusion coefficient determined for the calcium-sensitive contrast agents may be used to determine local tissue concentrations and to design infusion protocols that maintain the agent concentration at a steady state, thereby enabling quantitative sensing of the local calcium concentration. Copyright © 2014 John Wiley & Sons, Ltd.

  17. An axisymmetric diffusion experiment for the determination of diffusion and sorption coefficients of rock samples.

    Science.gov (United States)

    Takeda, M; Hiratsuka, T; Ito, K; Finsterle, S

    2011-04-25

    Diffusion anisotropy is a critical property in predicting migration of substances in sedimentary formations with very low permeability. The diffusion anisotropy of sedimentary rocks has been evaluated mainly from laboratory diffusion experiments, in which the directional diffusivities are separately estimated by through-diffusion experiments using different rock samples, or concurrently by in-diffusion experiments in which only the tracer profile in a rock block is measured. To estimate the diffusion anisotropy from a single rock sample, this study proposes an axisymmetric diffusion test, in which tracer diffuses between a cylindrical rock sample and a surrounding solution reservoir. The tracer diffusion between the sample and reservoir can be monitored from the reservoir tracer concentrations, and the tracer profile could also be obtained after dismantling the sample. Semi-analytical solutions are derived for tracer concentrations in both the reservoir and sample, accounting for an anisotropic diffusion tensor of rank two as well as the dilution effects from sampling and replacement of reservoir solution. The transient and steady-state analyses were examined experimentally and numerically for different experimental configurations, but without the need for tracer profiling. These experimental configurations are tested for in- and out-diffusion experiments using Koetoi and Wakkanai mudstones and Shirahama sandstone, and are scrutinized by a numerical approach to identify favorable conditions for parameter estimation. The analysis reveals the difficulty in estimating diffusion anisotropy; test configurations are proposed for enhanced identifiability of diffusion anisotropy. Moreover, it is demonstrated that the axisymmetric diffusion test is efficient in obtaining the sorption parameter from both steady-state and transient data, and in determining the effective diffusion coefficient if isotropic diffusion is assumed. Moreover, measuring reservoir concentrations in an

  18. An asixymmetric diffusion experiment for the determination of diffusion and sorption coefficients of rock samples

    Energy Technology Data Exchange (ETDEWEB)

    Takeda, M.; Hiratsuka, T.; Ito, K.; Finsterle, S.

    2011-02-01

    Diffusion anisotropy is a critical property in predicting migration of substances in sedimentary formations with very low permeability. The diffusion anisotropy of sedimentary rocks has been evaluated mainly from laboratory diffusion experiments, in which the directional diffusivities are separately estimated by through-diffusion experiments using different rock samples, or concurrently by in-diffusion experiments in which only the tracer profile in a rock block is measured. To estimate the diffusion anisotropy from a single rock sample, this study proposes an axisymmetric diffusion test, in which tracer diffuses between a cylindrical rock sample and a surrounding solution reservoir. The tracer diffusion between the sample and reservoir can be monitored from the reservoir tracer concentrations, and the tracer profile could also be obtained after dismantling the sample. Semi-analytical solutions are derived for tracer concentrations in both the reservoir and sample, accounting for an anisotropic diffusion tensor of rank two as well as the dilution effects from sampling and replacement of reservoir solution. The transient and steady-state analyses were examined experimentally and numerically for different experimental configurations, but without the need for tracer profiling. These experimental configurations are tested for in- and out-diffusion experiments using Koetoi and Wakkanai mudstones and Shirahama sandstone, and are scrutinized by a numerical approach to identify favorable conditions for parameter estimation. The analysis reveals the difficulty in estimating diffusion anisotropy; test configurations are proposed for enhanced identifiability of diffusion anisotropy. Moreover, it is demonstrated that the axisymmetric diffusion test is efficient in obtaining the sorption parameter from both steady-state and transient data, and in determining the effective diffusion coefficient if isotropic diffusion is assumed. Moreover, measuring reservoir concentrations in an

  19. Longitudinal diffusion MRI for treatment response assessment: Preliminary experience using an MRI-guided tri-cobalt 60 radiotherapy system.

    Science.gov (United States)

    Yang, Yingli; Cao, Minsong; Sheng, Ke; Gao, Yu; Chen, Allen; Kamrava, Mitch; Lee, Percy; Agazaryan, Nzhde; Lamb, James; Thomas, David; Low, Daniel; Hu, Peng

    2016-03-01

    To demonstrate the preliminary feasibility of a longitudinal diffusion magnetic resonance imaging (MRI) strategy for assessing patient response to radiotherapy at 0.35 T using an MRI-guided radiotherapy system (ViewRay). Six patients (three head and neck cancer, three sarcoma) who underwent fractionated radiotherapy were enrolled in this study. A 2D multislice spin echo single-shot echo planar imaging diffusion pulse sequence was implemented on the ViewRay system and tested in phantom studies. The same pulse sequence was used to acquire longitudinal diffusion data (every 2-5 fractions) on the six patients throughout the entire course of radiotherapy. The reproducibility of the apparent diffusion coefficient (ADC) measurements was assessed using reference regions and the temporal variations of the tumor ADC values were evaluated. In diffusion phantom studies, the ADC values measured on the ViewRay system matched well with reference ADC values with ViewRay MRI. Larger patient cohort studies are warranted to correlate the longitudinal diffusion measurements to patient outcomes. Such an approach may enable response-guided adaptive radiotherapy.

  20. D-BRAIN : Anatomically accurate simulated diffusion MRI brain data

    OpenAIRE

    Perrone, Daniele; Jeurissen, Ben; Aelterman, Jan; Roine, Timo; Sijbers, Jan; Pizurica, Aleksandra; Leemans, Alexander; Philips, Wilfried

    2016-01-01

    Diffusion Weighted (DW) MRI allows for the non-invasive study of water diffusion inside living tissues. As such, it is useful for the investigation of human brain white matter (WM) connectivity in vivo through fiber tractography (FT) algorithms. Many DW-MRI tailored restoration techniques and FT algorithms have been developed. However, it is not clear how accurately these methods reproduce the WM bundle characteristics in real-world conditions, such as in the presence of noise, partial volume...

  1. Diffusion-weighted MRI in acute posterior ischemic optic neuropathy

    International Nuclear Information System (INIS)

    Srinivasan, Sivasubramanian; Moorthy, Srikant; Sreekumar, KP; Kulkarni, Chinmay

    2012-01-01

    Blindness following surgery, especially cardiac surgery, has been reported sporadically, the most common cause being ischemic optic neuropathy. The role of MRI in the diagnosis of this condition is not well established. We present a case of postoperative posterior ischemic optic neuropathy that was diagnosed on diffusion-weighted MRI

  2. Diffusion and perfusion MRI for the localisation of epileptogenic foci in drug-resistant epilepsy

    International Nuclear Information System (INIS)

    Heiniger, P.; El-Koussy, M.; Kiefer, C.; Oswald, H.; Schroth, G.; Schindler, K.; Donati, F.; Loevblad, K.O.; Wissmeyer, M.; Mariani, L.; Weder, B.

    2002-01-01

    Drug-resistant epilepsy is an important clinical challenge, both diagnostically and therapeutically. More and more surgical options are being considered, but precise presurgical assessment is necessary. We prospectively studied eight patients with drug-resistant epilepsy, who underwent clinical examination, single photon emission computed tomography (SPECT) and interictal MRI, including diffusion- and perfusion-weighted echoplanar sequences. Lesions suspected on SPECT of being epileptogenic showed mild hypoperfusion, while the diffusion-weighted MRI (DWI) revealed increased apparent diffusion coefficients relative to the other side. However, these abnormalities were not visible on the corresponding maps. We showed that DWI and perfusion-weighted MRI could be used confirm the characteristics and site of an epileptogenic area in patients with drug-resistant epilepsy. (orig.)

  3. Benign and malignant skull-involved lesions: discriminative value of conventional CT and MRI combined with diffusion-weighted MRI.

    Science.gov (United States)

    Tu, Zhanhai; Xiao, Zebin; Zheng, Yingyan; Huang, Hongjie; Yang, Libin; Cao, Dairong

    2018-01-01

    Background Little is known about the value of computed tomography (CT) and magnetic resonance imaging (MRI) combined with diffusion-weighted imaging (DWI) in distinguishing malignant from benign skull-involved lesions. Purpose To evaluate the discriminative value of DWI combined with conventional CT and MRI for differentiating between benign and malignant skull-involved lesions. Material and Methods CT and MRI findings of 58 patients with pathologically proven skull-involved lesions (43 benign and 15 malignant) were retrospectively reviewed. Conventional CT and MRI characteristics and apparent diffusion coefficient (ADC) value of the two groups were evaluated and compared. Multivariate logistic regression and receiver operating characteristic (ROC) curve analyses were performed to assess the differential performance of each parameter separately and together. Results The presence of cortical defects or break-through and ill-defined margins were associated with malignant skull-involved lesions (both P benign and malignant skull-involved lesions. Conclusion The combination of CT, MRI, and DWI can help to differentiate malignant from benign skull-involved lesions. CT + MRI + DWI offers optimal sensitivity, while DWI offers optimal specificity.

  4. Determination of gas diffusion coefficients in undisturbed Boom clay

    International Nuclear Information System (INIS)

    Jacops, E.; Volckaert, G.; Maes, N.; Govaerts, J.; Weetjens, E.

    2012-01-01

    Document available in extended abstract form only. The Belgian agency for radioactive waste and enriched fissile materials Ondraf/Niras presently considers Boom Clay as a potential host formation for the disposal of high-level and long-lived radioactive waste. The production of gas is unavoidable within a geological repository. Gas is produced by different mechanisms: anaerobic corrosion of metals in waste and packaging, radiolysis of water and organic materials in the waste and engineered barriers and microbial degradation of various organic wastes. Corrosion and radiolysis yield mainly hydrogen while microbial degradation leads to methane and carbon dioxide. The gas generated in the near field of a geological repository will dissolve in the pore water and is transported away from the repository by diffusion as dissolved species. If the gas generation rate is larger than the diffusive flux, the pore water will become over-saturated and a free gas phase will form. Initially, isolated gas bubbles will accumulate until a continuous gas phase is formed. As gas pressure continues to increase, discrete gas pathways may be formed by tensile fractures within the rock fabric. Consequently, this entire process may locally and at least temporarily alter the hydraulic and mechanical properties of the engineered barriers and the clay and, perhaps, their performance. Therefore it is important to assess whether or not gas production rates might exceed the diffusive gas flux. The currently available gas diffusion parameters (D eff : effective diffusion coefficient) for hydrogen in Boom Clay, obtained from the MEGAS project, and re-evaluated after lead to an estimated D eff between 1.9 10 -12 and 1.5 10 -10 m 2 /s. Sensitivity calculations showed that this uncertainty on the diffusion coefficient, combined with that on the gas source term, made it impossible to exclude the formation of a free gas phase. To reduce the uncertainty, an experimental method was developed to determine

  5. Diffusion-weighted MRI of lymphoma: prognostic utility and implications for PET/MRI?

    Energy Technology Data Exchange (ETDEWEB)

    Punwani, Shonit; Taylor, Stuart A.; Halligan, Steve [University College London, Centre for Medical Imaging, London (United Kingdom); University College London Hospital, Department of Radiology, London (United Kingdom); Saad, Ziauddin Z.; Groves, Ashley [University College London Hospital, Institute of Nuclear Medicine, London (United Kingdom); Bainbridge, Alan [University College London Hospital, Department of Medical Physics and Bioengineering, London (United Kingdom); Daw, Stephen; Shankar, Ananth [University College London Hospital, Department of Paediatrics, London (United Kingdom); Humphries, Paul D. [University College London Hospital, Department of Radiology, London (United Kingdom); Great Ormond Street Hospital, Department of Radiology, London (United Kingdom)

    2013-03-15

    With the recent introduction of PET/MRI, we investigated whether diffusion-weighted imaging (DWI) can complement PET for predicting local treatment response in Hodgkin lymphoma. This retrospective study included 39 patients selected from a hospital database with a histological diagnosis of Hodgkin lymphoma undergoing whole-body MRI (supplemented by DWI) and PET/CT before and after two cycles of vincristine, etoposide, prednisolone and doxorubicin (OEPA). The pretreatment volume, MRI apparent diffusion coefficient (ADC) and PET maximum standardized uptake value (SUV{sub max}) of the largest nodal mass were determined quantitatively for evaluation of the local response following two cycles of OEPA. Quantitative pretreatment imaging biomarkers (disease volume, ADC, SUV{sub max}) were compared between sites with an adequate and those with an inadequate response using Fisher's exact test and Mann Whitney statistics. Multivariate models predictive of an inadequate response based on demographic/clinical features, pretreatment disease volume and SUV{sub max} without (model 1) and with (model 2) the addition of ADC were derived and crossvalidated. The ROC area under curve (AUC) was calculated for both models using the full dataset (training) and the crossvalidation (test) data. Sites with an adequate response had a significantly lower median pretreatment ADC (1.0 x 10{sup -3}mm{sup 2}s{sup -1}) than those with an inadequate response (1.26 x 10{sup -3}mm{sup 2}s{sup -1}; p < 0.01). There were no significant differences in patient demographic/clinical parameters, pretreatment SUV{sub max} or pretreatment nodal volume between sites with inadequate and adequate response. The ROC-AUCs for prediction of an inadequate response for the training and test data for model 1 were 0.90 and 0.53, and for model 2 were 0.84 and 0.71, respectively. DWI complements PET for prediction of site-specific interim response to chemotherapy. (orig.)

  6. Diffusion-weighted MRI of the transplanted liver

    International Nuclear Information System (INIS)

    Sandrasegaran, K.; Ramaswamy, R.; Ghosh, S.; Tahir, B.; Akisik, F.M.; Saxena, R.; Kwo, P.

    2011-01-01

    Aim: To assess the value of diffusion-weighted imaging (DWI) in evaluating parenchymal disorders following orthotopic liver transplantation (OLT). Materials and methods: This institutional review board-approved, retrospective study measured the hepatic apparent diffusion coefficients (ADC) in patients following OLT. Those with vascular complications or within 3 months of OLT were excluded. A single-shot echoplanar sequence with b values of 50, 400 (or 500), and 800 s/mm 2 was performed. Liver biopsy specimens [performed with a median of 17 days after magnetic resonance imaging (MRI)] were recorded for the presence and severity of parenchymal disorders, such as acute cellular rejection, and recurrence of fibrosis in all patients, and the recurrence of viral hepatitis in patients with hepatitis C. ADC values were measured blinded to histology in 41 patients (33 males) who had 56 MRI scans. Results: There was a significant difference in ADC values associated with a histological abnormality seen on core biopsy [n = 43, mean (SD) ADC of 0.91 (0.15)x10 -3 mm 2 /s] and those associated with no histological abnormality [n = 13, mean (SD) ADC of 1.11 (0.17)x10 -3 mm 2 /s; (p = 0.003)]. ADC values did not predict any of the individual parenchymal disorders on logistic regression analysis. When the ADC value was -3 mm 2 /s, there was a sensitivity and specificity of 85% and 72%, respectively, in predicting a parenchymal disorder (area under ROC curve = 0.84; 95% CI 0.72 to 0.92). Conclusion: ADC measurements may help in deciding which patients require core liver biopsy after OLT. However, ADC values are not likely to be reliable in differentiating between the various parenchymal disorders.

  7. Diffusion-weighted MRI of the transplanted liver

    Energy Technology Data Exchange (ETDEWEB)

    Sandrasegaran, K., E-mail: ksandras@iupui.edu [Department of Radiology, Indiana University School of Medicine, Indianapolis, IN (United States); Ramaswamy, R. [Department of Radiology, Indiana University School of Medicine, Indianapolis, IN (United States); Ghosh, S. [Department of Mathematics, Indiana University, IN (United States); Tahir, B.; Akisik, F.M. [Department of Radiology, Indiana University School of Medicine, Indianapolis, IN (United States); Saxena, R. [Department of Pathology, Indiana University School of Medicine, Indianapolis, IN (United States); Kwo, P. [Department of Medicine, Indiana University School of Medicine, Indianapolis, IN (United States)

    2011-09-15

    Aim: To assess the value of diffusion-weighted imaging (DWI) in evaluating parenchymal disorders following orthotopic liver transplantation (OLT). Materials and methods: This institutional review board-approved, retrospective study measured the hepatic apparent diffusion coefficients (ADC) in patients following OLT. Those with vascular complications or within 3 months of OLT were excluded. A single-shot echoplanar sequence with b values of 50, 400 (or 500), and 800 s/mm{sup 2} was performed. Liver biopsy specimens [performed with a median of 17 days after magnetic resonance imaging (MRI)] were recorded for the presence and severity of parenchymal disorders, such as acute cellular rejection, and recurrence of fibrosis in all patients, and the recurrence of viral hepatitis in patients with hepatitis C. ADC values were measured blinded to histology in 41 patients (33 males) who had 56 MRI scans. Results: There was a significant difference in ADC values associated with a histological abnormality seen on core biopsy [n = 43, mean (SD) ADC of 0.91 (0.15)x10{sup -3} mm{sup 2}/s] and those associated with no histological abnormality [n = 13, mean (SD) ADC of 1.11 (0.17)x10{sup -3} mm{sup 2}/s; (p = 0.003)]. ADC values did not predict any of the individual parenchymal disorders on logistic regression analysis. When the ADC value was <0.99x10{sup -3} mm{sup 2}/s, there was a sensitivity and specificity of 85% and 72%, respectively, in predicting a parenchymal disorder (area under ROC curve = 0.84; 95% CI 0.72 to 0.92). Conclusion: ADC measurements may help in deciding which patients require core liver biopsy after OLT. However, ADC values are not likely to be reliable in differentiating between the various parenchymal disorders.

  8. Pseudotumours in chronic kidney disease: Can diffusion-weighted MRI rule out malignancy

    International Nuclear Information System (INIS)

    Goyal, Ankur; Sharma, Raju; Bhalla, Ashu S.; Gamanagatti, Shivanand; Seth, Amlesh

    2013-01-01

    Highlights: •Conventional non-contrast MRI is unable to distinguish CKD pseudotumors from RCCs. •Pseudotumours in a background of CKD do not show restricted diffusion. •CKD pseudotumours demonstrate high ADC values whereas RCCs show restricted diffusion. •DW-MRI is reliable in ruling out malignancy incase of pseudotumours found in chronic kidney disease. •DW-MRI may obviate contrast administration and/or tissue sampling in renal pseudotumours and prevent inadvertent surgeries. -- Abstract: Objectives: To evaluate whether diffusion-weighted MRI (DW-MRI) can distinguish pseudotumours in chronic kidney disease (CKD pseudotumours) from renal-cell-carcinomas (RCCs) (with or without CKD) and whether it offers additional benefit over conventional MRI. Methods: One-hundred patients underwent MDCT, MRI and DW-MRI (at b-values of 0 and 500 s/mm 2 ) for evaluation of focal renal lesions. Of these, 20 patients with 40 CKD pseudotumours and 36 patients with 40 RCCs were retrospectively analyzed. T1-weighted, T2-weighted, diffusion-weighted images were evaluated, apparent-diffusion-coefficient (ADC) values were compared and receiver-operating-characteristic (ROC) curves were drawn to establish cut-off ADC-values. Results: 92.5% of CKD pseudotumours remained indeterminate after conventional MRI. On DW-MRI, none of them showed restricted diffusion and thus malignancy could be ruled out in 100% of the lesions. In contrast, all the solid RCCs showed diffusion restriction. Mean ADC-value for CKD pseudotumours was significantly higher than RCCs and surrounding diseased parenchyma [2.50 vs 1.56 (×10 −3 mm 2 /s) (P < 0.0001) and 2.05 (×10 −3 mm 2 /s) (P = 0.0001) respectively]. ROC analysis for differentiating CKD pseudotumours and RCC yielded high sensitivity (91.7%) and specificity (100%) for cut-off ADC-value of 2.04 (×10 −3 mm 2 /s). Conclusions: CKD pseudotumors usually remain indeterminate on conventional non-contrast MRI. DW-MRI can distinguish CKD pseudotumors

  9. Pseudotumours in chronic kidney disease: Can diffusion-weighted MRI rule out malignancy

    Energy Technology Data Exchange (ETDEWEB)

    Goyal, Ankur, E-mail: ankurgoyalaiims@gmail.com [Department of Radiodiagnosis, All India Institute of Medical Sciences (A.I.I.M.S.), New Delhi (India); Sharma, Raju, E-mail: raju152@yahoo.com [Department of Radiodiagnosis, All India Institute of Medical Sciences (A.I.I.M.S.), New Delhi (India); Bhalla, Ashu S., E-mail: ashubhalla1@yahoo.com [Department of Radiodiagnosis, All India Institute of Medical Sciences (A.I.I.M.S.), New Delhi (India); Gamanagatti, Shivanand, E-mail: shiv223@rediffmail.com [Department of Radiodiagnosis, All India Institute of Medical Sciences (A.I.I.M.S.), New Delhi (India); Seth, Amlesh, E-mail: amlesh.seth@gmail.com [Department of Urology, All India Institute of Medical Sciences (A.I.I.M.S.), New Delhi (India)

    2013-11-01

    Highlights: •Conventional non-contrast MRI is unable to distinguish CKD pseudotumors from RCCs. •Pseudotumours in a background of CKD do not show restricted diffusion. •CKD pseudotumours demonstrate high ADC values whereas RCCs show restricted diffusion. •DW-MRI is reliable in ruling out malignancy incase of pseudotumours found in chronic kidney disease. •DW-MRI may obviate contrast administration and/or tissue sampling in renal pseudotumours and prevent inadvertent surgeries. -- Abstract: Objectives: To evaluate whether diffusion-weighted MRI (DW-MRI) can distinguish pseudotumours in chronic kidney disease (CKD pseudotumours) from renal-cell-carcinomas (RCCs) (with or without CKD) and whether it offers additional benefit over conventional MRI. Methods: One-hundred patients underwent MDCT, MRI and DW-MRI (at b-values of 0 and 500 s/mm{sup 2}) for evaluation of focal renal lesions. Of these, 20 patients with 40 CKD pseudotumours and 36 patients with 40 RCCs were retrospectively analyzed. T1-weighted, T2-weighted, diffusion-weighted images were evaluated, apparent-diffusion-coefficient (ADC) values were compared and receiver-operating-characteristic (ROC) curves were drawn to establish cut-off ADC-values. Results: 92.5% of CKD pseudotumours remained indeterminate after conventional MRI. On DW-MRI, none of them showed restricted diffusion and thus malignancy could be ruled out in 100% of the lesions. In contrast, all the solid RCCs showed diffusion restriction. Mean ADC-value for CKD pseudotumours was significantly higher than RCCs and surrounding diseased parenchyma [2.50 vs 1.56 (×10{sup −3} mm{sup 2}/s) (P < 0.0001) and 2.05 (×10{sup −3} mm{sup 2}/s) (P = 0.0001) respectively]. ROC analysis for differentiating CKD pseudotumours and RCC yielded high sensitivity (91.7%) and specificity (100%) for cut-off ADC-value of 2.04 (×10{sup −3} mm{sup 2}/s). Conclusions: CKD pseudotumors usually remain indeterminate on conventional non-contrast MRI. DW-MRI

  10. Practical estimate of gradient nonlinearity for implementation of apparent diffusion coefficient bias correction.

    Science.gov (United States)

    Malkyarenko, Dariya I; Chenevert, Thomas L

    2014-12-01

    To describe an efficient procedure to empirically characterize gradient nonlinearity and correct for the corresponding apparent diffusion coefficient (ADC) bias on a clinical magnetic resonance imaging (MRI) scanner. Spatial nonlinearity scalars for individual gradient coils along superior and right directions were estimated via diffusion measurements of an isotropicic e-water phantom. Digital nonlinearity model from an independent scanner, described in the literature, was rescaled by system-specific scalars to approximate 3D bias correction maps. Correction efficacy was assessed by comparison to unbiased ADC values measured at isocenter. Empirically estimated nonlinearity scalars were confirmed by geometric distortion measurements of a regular grid phantom. The applied nonlinearity correction for arbitrarily oriented diffusion gradients reduced ADC bias from 20% down to 2% at clinically relevant offsets both for isotropic and anisotropic media. Identical performance was achieved using either corrected diffusion-weighted imaging (DWI) intensities or corrected b-values for each direction in brain and ice-water. Direction-average trace image correction was adequate only for isotropic medium. Empiric scalar adjustment of an independent gradient nonlinearity model adequately described DWI bias for a clinical scanner. Observed efficiency of implemented ADC bias correction quantitatively agreed with previous theoretical predictions and numerical simulations. The described procedure provides an independent benchmark for nonlinearity bias correction of clinical MRI scanners.

  11. Comparison of radon diffusion coefficients measured by transient-diffusion and steady-state laboratory methods

    International Nuclear Information System (INIS)

    Kalwarf, D.R.; Nielson, K.K.; Rich, D.C.; Rogers, V.C.

    1982-11-01

    A method was developed and used to determine radon diffusion coefficients in compacted soils by transient-diffusion measurements. A relative standard deviation of 12% was observed in repeated measurements with a dry soil by the transient-diffusion method, and a 40% uncertainty was determined for moistures exceeding 50% of saturation. Excellent agreement was also obtained between values of the diffusion coefficient for radon in air, as measured by the transient-diffusion method, and those in the published literature. Good agreement was also obtained with diffusion coefficients measured by a steady-state method on the same soils. The agreement was best at low moistures, averaging less than ten percent difference, but differences of up to a factor of two were observed at high moistures. The comparison of the transient-diffusion and steady-state methods at low moistures provides an excellent verification of the theoretical validity and technical accuracy of these approaches, which are based on completely independent experimental conditions, measurement methods and mathematical interpretations

  12. Apparent diffusion coefficient correlation with oesophageal tumour stroma and angiogenesis

    Energy Technology Data Exchange (ETDEWEB)

    Aoyagi, Tomoyoshi; Shuto, Kiyohiko; Okazumi, Shinichi; Hayano, Kohichi; Satoh, Asami; Saitoh, Hiroshige; Shimada, Hideaki; Nabeya, Yoshihiro; Matsubara, Hisahiro [Chiba University, Department of Frontier Surgery, Graduate School of Medicine, Chiba (Japan); Kazama, Toshiki [Chiba University, Department of Radiology, Graduate School of Medicine, Chiba (Japan)

    2012-06-15

    Because diffusion-weighted imaging (DWI) can predict the prognosis of patients with oesophageal squamous cell carcinoma (ESCC), we hypothesised that apparent diffusion coefficient (ADC) values might be correlated with the collagen content and tumour angiogenesis. The purpose of this study was to determine the correlation between ADC values of ESCC before treatment and oesophageal tumour stroma and angiogenesis. Seventeen patients with ESCC were enrolled. The ADC values were calculated from the DWI score. Seventeen patients who had undergone oesophagectomy were analysed for tumour stroma, vascular endothelial growth factor (VEGF) and CD34. Tissue collagen was stained with azocarmine and aniline blue to quantitatively analyse the extracellular matrix in cancer stroma. Tissues were stained with VEGF and CD34 to analyse the angiogenesis. The ADC values decreased with stromal collagen growth. We found a negative correlation between the tumour ADC and the amount of stromal collagen (r = -0.729, P = 0.001), i.e. the ADC values decreased with growth of VEGF. We also found a negative correlation between the ADC of the tumours and the amount of VEGF (r = 0.538, P = 0.026). Our results indicated that the ADC value may be a novel prognostic factor and contribute to the treatment of oesophageal cancer. circle Magnetic resonance apparent diffusion coefficient values inversely indicate tumour stromal collagen circle There is also negative correlation between ADCs and vascular endothelial growth factor circle ADC values may contribute to the treatment of oesophageal cancer. (orig.)

  13. Apparent diffusion coefficient correlation with oesophageal tumour stroma and angiogenesis

    International Nuclear Information System (INIS)

    Aoyagi, Tomoyoshi; Shuto, Kiyohiko; Okazumi, Shinichi; Hayano, Kohichi; Satoh, Asami; Saitoh, Hiroshige; Shimada, Hideaki; Nabeya, Yoshihiro; Matsubara, Hisahiro; Kazama, Toshiki

    2012-01-01

    Because diffusion-weighted imaging (DWI) can predict the prognosis of patients with oesophageal squamous cell carcinoma (ESCC), we hypothesised that apparent diffusion coefficient (ADC) values might be correlated with the collagen content and tumour angiogenesis. The purpose of this study was to determine the correlation between ADC values of ESCC before treatment and oesophageal tumour stroma and angiogenesis. Seventeen patients with ESCC were enrolled. The ADC values were calculated from the DWI score. Seventeen patients who had undergone oesophagectomy were analysed for tumour stroma, vascular endothelial growth factor (VEGF) and CD34. Tissue collagen was stained with azocarmine and aniline blue to quantitatively analyse the extracellular matrix in cancer stroma. Tissues were stained with VEGF and CD34 to analyse the angiogenesis. The ADC values decreased with stromal collagen growth. We found a negative correlation between the tumour ADC and the amount of stromal collagen (r = -0.729, P = 0.001), i.e. the ADC values decreased with growth of VEGF. We also found a negative correlation between the ADC of the tumours and the amount of VEGF (r = 0.538, P = 0.026). Our results indicated that the ADC value may be a novel prognostic factor and contribute to the treatment of oesophageal cancer. circle Magnetic resonance apparent diffusion coefficient values inversely indicate tumour stromal collagen circle There is also negative correlation between ADCs and vascular endothelial growth factor circle ADC values may contribute to the treatment of oesophageal cancer. (orig.)

  14. Conventions and nomenclature for double diffusion encoding NMR and MRI

    DEFF Research Database (Denmark)

    Shemesh, Noam; Jespersen, Sune N; Alexander, Daniel C

    2015-01-01

    , such as double diffusion encoding (DDE) NMR and MRI, may provide novel quantifiable metrics that are less easily inferred from conventional diffusion acquisitions. Despite the growing interest on the topic, the terminology for the pulse sequences, their parameters, and the metrics that can be derived from them...

  15. Purulent meningitis with unusual diffusion-weighted MRI findings

    International Nuclear Information System (INIS)

    Abe, M.; Takayama, Y.; Yamashita, H.; Noguchi, M.; Sagoh, T.

    2002-01-01

    We describe unusual findings obtained by diffusion-weighted magnetic resonance imaging (MRI) in a patient with acute purulent meningitis caused by penicillin-resistant Streptococcus pneumoniae. Along cerebral convexities and the Sylvian fissure, multiple small intense lesions showed high signal intensity in these sequences. This may be the first report of diffusion-weighted in purulent meningitis

  16. Diffusion microscopist simulator - The development and application of a Monte Carlo simulation system for diffusion MRI

    International Nuclear Information System (INIS)

    Yeh, C.H.

    2011-09-01

    Diffusion magnetic resonance imaging (dMRI) has made a significant breakthrough in neurological disorders and brain research thanks to its exquisite sensitivity to tissue cyto-architecture. However, as the water diffusion process in neuronal tissues is a complex biophysical phenomena at molecular scale, it is difficult to infer tissue microscopic characteristics on a voxel scale from dMRI data. The major methodological contribution of this thesis is the development of an integrated and generic Monte Carlo simulation framework, 'Diffusion Microscopist Simulator' (DMS), which has the capacity to create 3D biological tissue models of various shapes and properties, as well as to synthesize dMRI data for a large variety of MRI methods, pulse sequence design and parameters. DMS aims at bridging the gap between the elementary diffusion processes occurring at a micrometric scale and the resulting diffusion signal measured at millimetric scale, providing better insights into the features observed in dMRI, as well as offering ground-truth information for optimization and validation of dMRI acquisition protocols for different applications. We have verified the performance and validity of DMS through various benchmark experiments, and applied to address particular research topics in dMRI. Based on DMS, there are two major application contributions in this thesis. First, we use DMS to investigate the impact of finite diffusion gradient pulse duration (delta) on fibre orientation estimation in dMRI. We propose that current practice of using long delta, which is enforced by the hardware limitation of clinical MRI scanners, is actually beneficial for mapping fibre orientations, even though it violates the underlying assumption made in q-space theory. Second, we employ DMS to investigate the feasibility of estimating axon radius using a clinical MRI system. The results suggest that the algorithm for mapping the direct microstructures is applicable to dMRI data acquired from

  17. Role of PROPELLER diffusion-weighted imaging and apparent diffusion coefficient in the evaluation of pituitary adenomas

    International Nuclear Information System (INIS)

    Mahmoud, Omar M.; Tominaga, Atsushi; Amatya, Vishwa Jeet; Ohtaki, Megu; Sugiyama, Kazuhiko; Sakoguchi, Tetsuhiko; Kinoshita, Yasuyuki; Takeshima, Yukio; Abe, Nobukazu; Akiyama, Yuji; El-Ghoriany, Ahmad I.; Alla, Abdel Karim H. Abd; El-Sharkawy, Mostafa A.M.; Arita, Kazunori; Kurisu, Kaoru; Yamasaki, Fumiyuki

    2011-01-01

    Objective: The relationship between tumor consistency and apparent diffusion coefficient (ADC) values is controversial. We evaluated the role of the ADC using an advanced diffusion-weighted imaging (DWI) technique. We employed periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER) DWI acquired on a 3-T magnetic resonance imaging (MRI) scanner to assess the consistency of pituitary adenomas and examined the relationship between the ADC and the hormone secretion status of the tumors and their MIB-1 labeling index (MIB-1 LI). Materials and methods: The study protocol was approved by our institutional review board. We retrospectively studied 24 operated patients with pituitary adenomas who had undergone PROPELLER DWI on a 3-T MRI scanner. Conventional MRI findings were expressed as the ratio of the signal intensity (SI) in the lesions to the SI of the normal white matter and the degree of contrast enhancement. Minimum-, mean-, and maximum ADC (ADC min , ADC mean , ADC max ) values were calculated. The consistency of the tumors was determined by neurosurgeons. All surgical specimens were submitted for histological study to calculate the MIB-1 LI and the percent collagen content. Preoperative MRI-, intraoperative-, and histological findings were analyzed by a statistician. Results: Our study included 15 soft-, 5 fibrous-, and 4 hard tumors. Tumor consistency was strongly associated with the percent collagen content. However, neither the tumor consistency nor the percent collagen content was correlated with MRI findings or ADC values. The SI of growth hormone-producing adenomas on T2-WI was lower than of the other pituitary adenomas studied (p < 0.01); no other significant difference was found in the ADC or on conventional MRI between pituitary adenomas with different secretory functions. The MIB-1 LI of pituitary adenomas was not correlated with their appearance on conventional MRI or their ADC values. Conclusion: Using the PROPELLER DWI

  18. Role of PROPELLER diffusion-weighted imaging and apparent diffusion coefficient in the evaluation of pituitary adenomas

    Energy Technology Data Exchange (ETDEWEB)

    Mahmoud, Omar M. [Department of Neurosurgery, Graduate School of Biomedical Sciences, Hiroshima University, 1-2-3 Kasumi, Minami-ku, Hiroshima 734-8551 (Japan); Department of Radiology, South Egypt Cancer Institute, Assiut University, Assiut 71515 (Egypt); Tominaga, Atsushi [Department of Neurosurgery, Graduate School of Biomedical Sciences, Hiroshima University, 1-2-3 Kasumi, Minami-ku, Hiroshima 734-8551 (Japan); Amatya, Vishwa Jeet [Department of Pathology, Graduate School of Biomedical Sciences, Hiroshima University, Hiroshima 734-8551 (Japan); Ohtaki, Megu [Department of Environmetrics and Biometrics, Research Institute for Radiation Biology and Medicine, Hiroshima University, Hiroshima 734-8551 (Japan); Sugiyama, Kazuhiko; Sakoguchi, Tetsuhiko; Kinoshita, Yasuyuki [Department of Neurosurgery, Graduate School of Biomedical Sciences, Hiroshima University, 1-2-3 Kasumi, Minami-ku, Hiroshima 734-8551 (Japan); Takeshima, Yukio [Department of Pathology, Graduate School of Biomedical Sciences, Hiroshima University, Hiroshima 734-8551 (Japan); Abe, Nobukazu; Akiyama, Yuji [Department of Clinical Radiology, Hiroshima University Hospital, Hiroshima 734-8551 (Japan); El-Ghoriany, Ahmad I. [Department of Neurosurgery, Faculty of Medicine, Assiut University, Assiut 71515 (Egypt); Alla, Abdel Karim H. Abd; El-Sharkawy, Mostafa A.M. [Department of Radiology, Faculty of Medicine, Assiut University, Assiut 71515 (Egypt); Arita, Kazunori [Department of Neurosurgery, Graduate School of Medical and Dental Sciences, Kagoshima University, Kagoshima (Japan); Kurisu, Kaoru [Department of Neurosurgery, Graduate School of Biomedical Sciences, Hiroshima University, 1-2-3 Kasumi, Minami-ku, Hiroshima 734-8551 (Japan); Yamasaki, Fumiyuki, E-mail: fyama@hiroshima-u.ac.jp [Department of Neurosurgery, Graduate School of Biomedical Sciences, Hiroshima University, 1-2-3 Kasumi, Minami-ku, Hiroshima 734-8551 (Japan)

    2011-11-15

    Objective: The relationship between tumor consistency and apparent diffusion coefficient (ADC) values is controversial. We evaluated the role of the ADC using an advanced diffusion-weighted imaging (DWI) technique. We employed periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER) DWI acquired on a 3-T magnetic resonance imaging (MRI) scanner to assess the consistency of pituitary adenomas and examined the relationship between the ADC and the hormone secretion status of the tumors and their MIB-1 labeling index (MIB-1 LI). Materials and methods: The study protocol was approved by our institutional review board. We retrospectively studied 24 operated patients with pituitary adenomas who had undergone PROPELLER DWI on a 3-T MRI scanner. Conventional MRI findings were expressed as the ratio of the signal intensity (SI) in the lesions to the SI of the normal white matter and the degree of contrast enhancement. Minimum-, mean-, and maximum ADC (ADC{sub min}, ADC{sub mean}, ADC{sub max}) values were calculated. The consistency of the tumors was determined by neurosurgeons. All surgical specimens were submitted for histological study to calculate the MIB-1 LI and the percent collagen content. Preoperative MRI-, intraoperative-, and histological findings were analyzed by a statistician. Results: Our study included 15 soft-, 5 fibrous-, and 4 hard tumors. Tumor consistency was strongly associated with the percent collagen content. However, neither the tumor consistency nor the percent collagen content was correlated with MRI findings or ADC values. The SI of growth hormone-producing adenomas on T2-WI was lower than of the other pituitary adenomas studied (p < 0.01); no other significant difference was found in the ADC or on conventional MRI between pituitary adenomas with different secretory functions. The MIB-1 LI of pituitary adenomas was not correlated with their appearance on conventional MRI or their ADC values. Conclusion: Using the

  19. Mathematical methods for diffusion MRI processing

    International Nuclear Information System (INIS)

    Lenglet, C.; Lenglet, C.; Sapiro, G.; Campbell, J.S.W.; Pike, G.B.; Campbell, J.S.W.; Siddiqi, K.; Descoteaux, M.; Haro, G.; Wassermann, D.; Deriche, R.; Wassermann, D.; Anwander, A.; Thompson, P.M.

    2009-01-01

    In this article, we review recent mathematical models and computational methods for the processing of diffusion Magnetic Resonance Images, including state-of-the-art reconstruction of diffusion models, cerebral white matter connectivity analysis, and segmentation techniques. We focus on Diffusion Tensor Images (DTI) and Q-Ball Images (QBI). (authors)

  20. Density dependence of the diffusion coefficient of alkali metals

    International Nuclear Information System (INIS)

    Adebayo, G.A.; Anusionwu, B.C.; Njah, A.N.; Mathew, B.; Fabamise, O.A.T.

    2004-06-01

    The effect of density on transport coefficients of liquid Li, Na and K at high temperatures using the method of Molecular Dynamics simulation has been studied. Simulation of these liquid alkali metals were carried out with 800 particles in simulation boxes with periodic boundary conditions imposed. In order to test the reliability of the interatomic potential used in the calculations, experimental data on the structural properties were compared with calculated results. The calculations showed a linear relationship between the density and the diffusion coefficient in all the systems investigated except in lithium, where, due to the small size of the atom, standard molecular dynamics simulation method may not be appropriate for calculating the properties of interest. (author)

  1. New MRI technologies. Diffusion MRI and its application to functional neuroimaging and analyses of white matter integrity

    International Nuclear Information System (INIS)

    Kobayashi, Tetsuo

    2010-01-01

    Described is the technological aspect of MRI, MR diffusion-weighted imaging (MR-DWI), principles of its measurement and application for imaging the cerebral function and for aiding the quantitative diagnosis of brain diseases. The author explains the principle of MR imaging process; diffusion properties of water molecules, MR-DWI based on them and DW-fMRI of the brain; MR-diffusion tensor imaging (MR-DTI), its analysis and color acquisition, and tracking of white matter nerve fibers; analysis of white matter lesions by the tracking; and the new tracking method at the chiasm of nerve fascicles. The usual fMRI reflects the blood oxygen level depending (BOLD) signals whereas recently attracted DW-fMRI, the volume changes of nerve cells concomitant to nerve activation accompanying apparent changes of water diffusion coefficients in and out of cells which occur faster than BOLD signs, resulting in higher resolution of time and space. However, DWI requires the higher intensity of static magnetic field like 3T. MR-DTI acquires the anisotropic diffusion of water molecules using MR-DWI technique with application of 6 or more motion probing gradients, thus makes it possible to track the running directions of nerve fibers and capillary vessels, and is proposed to be a useful mean of specific fiber tracking in the white matter when displayed by 3 different colors exhibiting the directions like the right/left (x axis, red), anterior/posterior (y, green) and upper/lower (z, blue) sides of head. Recently, MR-DWI and MR-DTI have been found usable for pathogenic studies of brain diseases such as dementia. Tensor anisotropy is apparently lowered at the chiasm of nerve fascicles, the cause of tracking error, for which authors have developed a new method using the similarity of directional vector, not of tensor, before and behind the chiasm. As exemplified, MRI technology is further advancing even at present. (T.T.)

  2. The importance of correcting for signal drift in diffusion MRI

    OpenAIRE

    Vos, Sjoerd B; Tax, Chantal M W; Luijten, Peter R; Ourselin, Sebastien; Leemans, Alexander; Froeling, Martijn

    2017-01-01

    PURPOSE: To investigate previously unreported effects of signal drift as a result of temporal scanner instability on diffusion MRI data analysis and to propose a method to correct this signal drift. METHODS: We investigated the signal magnitude of non-diffusion-weighted EPI volumes in a series of diffusion-weighted imaging experiments to determine whether signal magnitude changes over time. Different scan protocols and scanners from multiple vendors were used to verify this on phantom data, a...

  3. Modifications of pancreatic diffusion MRI by tissue characteristics: what are we weighting for?

    Science.gov (United States)

    Nissan, Noam

    2017-08-01

    Diffusion-weighted imaging holds the potential to improve the diagnosis and biological characterization of pancreatic disease, and in particular pancreatic cancer, which exhibits decreased values of the apparent diffusion coefficient (ADC). Yet, variable and overlapping ADC values have been reported for the healthy and the pathological pancreas, including for cancer and other benign conditions. This controversy reflects the complexity of probing the water-diffusion process in the pancreas, which is dependent upon multiple biological factors within this organ's unique physiological environment. In recent years, extensive studies have investigated the correlation between tissue properties including cellularity, vascularity, fibrosis, secretion and microstructure and pancreatic diffusivity. Understanding how the various physiological and pathological features and the underlying functional processes affect the diffusion measurement may serve to optimize the method for improved diagnostic gain. Therefore, the aim of the present review article is to elucidate the relationship between pancreatic tissue characteristics and diffusion MRI measurement. Copyright © 2017 John Wiley & Sons, Ltd.

  4. Unsaturated soil moisture drying and wetting diffusion coefficient measurements in the laboratory.

    Science.gov (United States)

    2009-09-01

    ABSTRACTTransient moisture flow in an unsaturated soil in response to suction changes is controlled by the unsaturated moisture diffusion coefficient. The moisture diffusion coefficient can be determined by measuring suction profiles over time. The l...

  5. Evaluation of downwelling diffuse attenuation coefficient algorithms in the Red Sea

    KAUST Repository

    Tiwari, Surya Prakash; Yellepeddi, Sarma B.; Jones, Burton

    2016-01-01

    to comprehend the diffuse attenuation coefficient and its relationship with in situ properties. Two apparent optical properties, spectral remote sensing reflectance (Rrs) and the downwelling diffuse attenuation coefficient (Kd), are calculated from vertical

  6. Continuous diffusion signal, EAP and ODF estimation via Compressive Sensing in diffusion MRI.

    Science.gov (United States)

    Merlet, Sylvain L; Deriche, Rachid

    2013-07-01

    In this paper, we exploit the ability of Compressed Sensing (CS) to recover the whole 3D Diffusion MRI (dMRI) signal from a limited number of samples while efficiently recovering important diffusion features such as the Ensemble Average Propagator (EAP) and the Orientation Distribution Function (ODF). Some attempts to use CS in estimating diffusion signals have been done recently. However, this was mainly an experimental insight of CS capabilities in dMRI and the CS theory has not been fully exploited. In this work, we also propose to study the impact of the sparsity, the incoherence and the RIP property on the reconstruction of diffusion signals. We show that an efficient use of the CS theory enables to drastically reduce the number of measurements commonly used in dMRI acquisitions. Only 20-30 measurements, optimally spread on several b-value shells, are shown to be necessary, which is less than previous attempts to recover the diffusion signal using CS. This opens an attractive perspective to measure the diffusion signals in white matter within a reduced acquisition time and shows that CS holds great promise and opens new and exciting perspectives in diffusion MRI (dMRI). Copyright © 2013 Elsevier B.V. All rights reserved.

  7. Diffusion-Weighted MRI for the Assessment of Liver Fibrosis: Principles and Applications

    Directory of Open Access Journals (Sweden)

    Stefano Palmucci

    2015-01-01

    Full Text Available The importance of an early identification of hepatic fibrosis has been emphasized, in order to start therapy and obtain fibrosis regression. Biopsy is the gold-standard method for the assessment of liver fibrosis in chronic liver diseases, but it is limited by complications, interobserver variability, and sampling errors. Several noninvasive methods have been recently introduced into clinical routine, in order to detect liver fibrosis early. One of the most diffuse approaches is represented by diffusion-weighted liver MRI. In this review, the main technical principles are briefly reported in order to explain the rationale for clinical applications. In addition, roles of apparent diffusion coefficient, intravoxel incoherent motion, and relative apparent diffusion coefficient are also reported, showing their advantages and limits.

  8. An inverse moisture diffusion algorithm for the determination of diffusion coefficient

    Science.gov (United States)

    Jen Y. Liu; William T. Simpson; Steve P. Verrill

    2000-01-01

    The finite difference approximation is applied to estimate the moisture-dependent diffusion coefficient by utilizing test data of isothermal moisture desorption in northern red oak (Quercus rubra). The test data contain moisture distributions at discrete locations across the thickness of specimens, which coincides with the radial direction of northern red oak, and at...

  9. Role of apparent diffusion coefficient values and diffusion weighted magnetic resonance imaging in differentiation between benign and malignant thyroid nodules

    International Nuclear Information System (INIS)

    Incedayi, M.; Sivrioglu, A.; Mutlu, H.; Sonmez, G.; Velioglu, M.; Sildiroglu, O.; Basekim, C.; Kizilkaya, E.

    2012-01-01

    Full text: Objective: The purpose of the study was to differentiate between benign and malignant thyroid nodules using nodule-spinal cord signal intensity and nodule apparent diffusion coefficient (ADC) ratios on diffusion weighted magnetic resonance imaging. Materials and methods: Forty-four patients (27 females, 17 males; mean age 49) with nodules who underwent diffusion weighted magnetic resonance imaging (DW-MRI) were included in this study. The images were acquired with 0, 50, 400 and 1000 s/mm 2 b values. ADC maps were calculated afterwards. Fine needle aspiration biopsies (FNAB) were performed at the same day with DW-MRI acquisition. The diagnosis in patients where malignity was detected after FNAB was confirmed by histopathologic analysis of the operation material. The signal intensities of the spinal cord and the nodule were measured additionally, over b-1000 diffusion weighted images. Nodule /cord signal intensity (SI) ratios were obtained and the digital values were calculated by dividing to ADC values estimated for each nodule. Statistical analysis was performed. Results: The (nodule SI-cord SI)/nodule ADC ratio is calculated in the DW images and a statistically significant relationship was found between this ratio and the histopathology of the nodules (p<0.001). The ratio was determined as 0.27 in benign, and 0.86 in malignant lesions. The result of ROC analysis was statistically significant, and the area under Receiver Operating Characteristic (ROC) curve (100%) was considerably high. The threshold value was calculated as 0.56 according to the ROC analysis. According to this threshold value, the sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and accuracy rates for (nodule SI/cord SI)/ADC ratios in differentiating benign from malignant thyroid nodules are calculated as 100%, 97%, 83%, 100%, and 98%, respectively. Conclusion: We have found that (nodule/cord SI)/ nodule ADC ratio has the highest values for

  10. Abnormal diffusion-weighted MRI in medulloblastoma: does it reflect small cell histology?

    International Nuclear Information System (INIS)

    Kotsenas, A.L.; Roth, T.C.; Manness, W.K.; Faerber, E.N.

    1999-01-01

    A 12-year-old boy presented with the classic CT and MRI findings of medulloblastoma and the unusual finding of increased signal on diffusion MRI. The small-cell histology of medulloblastoma may account for the increased signal seen on diffusion MRI. Diffusion MRI with echoplanar technique may be useful in evaluation of these tumors and metastatic disease. (orig.)

  11. Measurements of the diffusion and reflection coefficients of Cd(1S0) in noble gases

    International Nuclear Information System (INIS)

    Rudecki, P.; Domyslawska, J.

    2003-01-01

    A new method of simultaneous determining of the diffusion coefficient and the reflection coefficient of atoms from the reservoir walls is presented. The diffusion coefficient of cadmium atoms in the ground state in buffer noble gas atoms such as Ne, Ar, Kr and Xe and reflection coefficient of Cd atoms from the quartz cell wall in the temperature range 350-550 K were determined. Experimental values diffusion coefficient are compared with theoretical ones calculated from a available potentials. (author)

  12. White matter biomarkers from diffusion MRI

    Science.gov (United States)

    Nørhøj Jespersen, Sune

    2018-06-01

    As part of an issue celebrating 2 decades of Joseph Ackerman editing the Journal of Magnetic Resonance, this paper reviews recent progress in one of the many areas in which Ackerman and his lab has made significant contributions: NMR measurement of diffusion in biological media, specifically in brain tissue. NMR diffusion signals display exquisite sensitivity to tissue microstructure, and have the potential to offer quantitative and specific information on the cellular scale orders of magnitude below nominal image resolution when combined with biophysical modeling. Here, I offer a personal perspective on some recent advances in diffusion imaging, from diffusion kurtosis imaging to microstructural modeling, and the connection between the two. A new result on the estimation accuracy of axial and radial kurtosis with axially symmetric DKI is presented. I moreover touch upon recently suggested generalized diffusion sequences, promising to offer independent microstructural information. We discuss the need and some methods for validation, and end with an outlook on some promising future directions.

  13. Dipy, a library for the analysis of diffusion MRI data.

    Science.gov (United States)

    Garyfallidis, Eleftherios; Brett, Matthew; Amirbekian, Bagrat; Rokem, Ariel; van der Walt, Stefan; Descoteaux, Maxime; Nimmo-Smith, Ian

    2014-01-01

    Diffusion Imaging in Python (Dipy) is a free and open source software project for the analysis of data from diffusion magnetic resonance imaging (dMRI) experiments. dMRI is an application of MRI that can be used to measure structural features of brain white matter. Many methods have been developed to use dMRI data to model the local configuration of white matter nerve fiber bundles and infer the trajectory of bundles connecting different parts of the brain. Dipy gathers implementations of many different methods in dMRI, including: diffusion signal pre-processing; reconstruction of diffusion distributions in individual voxels; fiber tractography and fiber track post-processing, analysis and visualization. Dipy aims to provide transparent implementations for all the different steps of dMRI analysis with a uniform programming interface. We have implemented classical signal reconstruction techniques, such as the diffusion tensor model and deterministic fiber tractography. In addition, cutting edge novel reconstruction techniques are implemented, such as constrained spherical deconvolution and diffusion spectrum imaging (DSI) with deconvolution, as well as methods for probabilistic tracking and original methods for tractography clustering. Many additional utility functions are provided to calculate various statistics, informative visualizations, as well as file-handling routines to assist in the development and use of novel techniques. In contrast to many other scientific software projects, Dipy is not being developed by a single research group. Rather, it is an open project that encourages contributions from any scientist/developer through GitHub and open discussions on the project mailing list. Consequently, Dipy today has an international team of contributors, spanning seven different academic institutions in five countries and three continents, which is still growing.

  14. Apparent diffusion coefficient in glioblastoma with PNET-like components, a GBM variant.

    Science.gov (United States)

    Ali, Saad; Joseph, Nancy M; Perry, Arie; Barajas, Ramon F; Cha, Soonmee

    2014-09-01

    Glioblastoma (GBM) with primitive neuroectodermal tumor (PNET)-like (GBM-PNET) components is a rare variant of GBM. Recent studies describe PNET-like clinical behavior in these patients-with significantly increased propensity for CSF dissemination and a benefit of "PNET-like" chemotherapy. The imaging appearance of GBM-PNET is not well-described and given areas of marked cellularity in the PNET components one might expect significantly reduced diffusion on MRI. The purpose of this study is to quantitatively evaluate the diffusion characteristics in GBM-PNET and compare them with conventional GBMs. Nine patients with surgical specimens yielding GBM-PNET were identified from the UCSF Pathology files. MR images of these patients were reviewed retrospectively. DWI (diffusion-weighted imaging) sequences were analyzed with multiple regions of interests placed within the tumor, and ADC (apparent diffusion coefficient) values were measured. Results were compared to previously published ADC values in pathology-proven conventional GBM cases from our institution. Reduced ADC was seen in GBM-PNET (mean 581 × 10(-6) mm(2)/s, range 338-817) compared to previously published mean of 1,030 × 10(-6) mm(2)/s in the enhancing components of conventional GBMs. We report substantially reduced ADC values in GBM-PNETs compared to conventional GBMs. If demonstrated in a larger sample, when areas of marked reduced diffusion are seen in a suspected GBM, MRI may appropriately direct tissue sampling and can advocate a thorough search for PNET-like components on histopathology. These patients may have a higher chance of developing CSF dissemination and may benefit from "PNET-like" platinum-based chemotherapy.

  15. Apparent diffusion coefficient values and dynamic contrast enhancement patterns in differentiating seminomas from nonseminomatous testicular neoplasms

    International Nuclear Information System (INIS)

    Tsili, Athina C.; Sylakos, Anastasios; Ntorkou, Alexandra; Stavrou, Sotirios; Astrakas, Loukas G.; Sofikitis, Nikolaos; Argyropoulou, Maria I.

    2015-01-01

    Highlights: • Functional MRI in the characterization of testicular germ cell tumors was assessed. • ADC values proved useful in the characterization of testicular germ cell tumors. • Testicular germ cell tumors had similar enhancement patterns of dynamic MRI. - Abstract: Introduction: The aim of this study is to investigate the role of apparent diffusion coefficient (ADC) values and dynamic contrast enhancement (DCE) patterns in differentiating seminomas from nonseminomatous germ cell tumors (NSGCTs). Materials and methods: The MRI examinations of the scrotum of 26 men with histologically proven testicular GCTs were reviewed. DWI was performed in all patients, using a single shot, multi-slice spin-echo planar diffusion pulse sequence and b-values of 0 and 900 s/mm 2 . Subtraction DCE-MRI was performed in 20 cases using a 3D fast-field echo sequence after gadolinium administration. Time-signal intensity curves were created and semi-quantitative parameters (peak enhancement, time to peak, wash-in and wash-out rate) were calculated. The Student's t-test was used to compare the mean values of ADC, peak enhancement, time to peak, wash-in and wash-out rate between seminomas and NSGCTs. ROC analysis was also performed. Results: Histopathology disclosed the presence of 15 seminomas and 11 NSGCTs. The mean ± s.d. of ADC values (× 10 −3 mm 2 /s) of seminomas (0.59 ± 0.009) were significantly lower than those of NSGCTs (0.90 ± 0.33) (P = 0.01). The optimal ADC cut-off value was 0.68 × 10 −3 mm 2 /s. No differences between the two groups were observed for peak enhancement (P = 0.18), time to peak (P = 0.63) wash-in rate (P = 0.32) and wash-out rate (P = 0.18). Conclusions: ADC values may be used to preoperatively differentiate seminomas from NSGCTs

  16. Correlation between tissue metabolism and cellularity assessed by standardized uptake value and apparent diffusion coefficient in peritoneal metastasis.

    Science.gov (United States)

    Yu, Xue; Lee, Elaine Yuen Phin; Lai, Vincent; Chan, Queenie

    2014-07-01

    To evaluate the correlation between standardized uptake value (SUV) (tissue metabolism) and apparent diffusion coefficient (ADC) (water diffusivity) in peritoneal metastases. Patients with peritoneal dissemination detected on (18)F-fluorodeoxyglucose positron emission tomography combined with computed tomography (FDG-PET/CT) were prospectively recruited for MRI examinations with informed consent and the study was approved by the local Institutional Review Board. FDG-PET/CT, diffusion-weighted imaging (DWI), MRI, and DWI/MRI images were independently reviewed by two radiologists based on visual analysis. SUVmax/SUVmean and ADCmin/ADCmean were obtained manually by drawing ROIs over the peritoneal metastases on FDG-PET/CT and DWI, respectively. Diagnostic characteristics of each technique were evaluated. Pearson's coefficient and McNemar and Kappa tests were used for statistical analysis. Eight patients were recruited for this prospective study and 34 peritoneal metastases were evaluated. ADCmean was significantly and negatively correlated with SUVmax (r = -0.528, P = 0.001) and SUVmean (r = -0.548, P = 0.001). ADCmin had similar correlation with SUVmax (r = -0.508, P = 0.002) and SUVmean (r = -0.513, P = 0.002). DWI/MRI had high diagnostic performance (accuracy = 98%) comparable to FDG-PET/CT, in peritoneal metastasis detection. Kappa values were excellent for all techniques. There was a significant inverse correlation between SUV and ADC. © 2013 Wiley Periodicals, Inc.

  17. Apparent diffusion coefficients of breast tumors. Clinical application

    International Nuclear Information System (INIS)

    Hatakenaka, Masamitsu; Soeda, Hiroyasu; Yabuuchi, Hidetake; Matsuo, Yoshio; Kamitani, Takeshi; Oda, Yoshinao; Tsuneyoshi, Masazumi; Honda, Hiroshi

    2008-01-01

    The purpose of this study was to evaluate the usefulness of apparent diffusion coefficient (ADC) for the differential diagnosis of breast tumors and to determine the relation between ADC and tumor cellularity. One hundred and thirty-six female patients (age range, 17-83 years; average age, 51.7 years) with 140 histologically proven breast tumors underwent diffusion-weighted magnetic resonance (MR) imaging (DWI) using the spin-echo echo-planar technique, and the ADCs of the tumors were calculated using 3 different b values, 0, 500, and 1000 s/mm 2 . The diagnoses consisted of fibroadenoma (FA, n=16), invasive ductal carcinoma, not otherwise specified (IDC, n=117), medullary carcinoma (ME, n=3) and mucinous carcinoma (MU, n=4). Tumor cellularity was calculated from surgical specimens. The ADCs of breast tumors and cellularity were compared between different histological types by analysis of variance and Scheffe's post hoc test. The correlation between tumor cellularity and ADC was analyzed by Pearson correlation test. Significant differences were observed in ADCs between FA and all types of cancers (P 2 =0.451). The ADC may potentially help in differentiating benign and malignant breast tumors. Tumor ADC correlates inversely with tumor cellularity. (author)

  18. Solution of time dependent atmospheric diffusion equation with a proposed diffusion coefficient

    International Nuclear Information System (INIS)

    Mayhoub, A.B.; Essa, KH.S.M.; Aly, SH.

    2004-01-01

    One-dimensional model for the dispersion of passive atmospheric contaminant (not included chemical reactions) in the atmospheric boundary layer is considered. On the basis of the gradient transfer theory (K-theory), the time dependent diffusion equation represents the dispersion of the pollutants is solved analytically. The solution depends on diffusion coefficient K', which is expressed in terms of the friction velocity 'u the vertical coordinate -L and the depth of the mixing layer 'h'. The solution is obtained to either the vertical coordinate 'z' is less or greater than the mixing height 'h'. The obtained solution may be applied to study the atmospheric dispersion of pollutants

  19. Differentiation of thyroid nodules using diffusion-weighted MRI

    African Journals Online (AJOL)

    Lamiss Mohamed Abd el Aziz

    2014-10-19

    Oct 19, 2014 ... technique for brain tumors. DWI is sensitive to changes in the microstructural organization of tissue that may affect water diffusion. It has been used to evaluate head and neck tumors.9–11 The Apparent Diffusion Coefficient (ADC) value is a quantitative parameter for distinguishing malignant tumors from ...

  20. Procedure for obtaining neutron diffusion coefficients from neutron transport Monte Carlo calculations (AWBA Development Program)

    International Nuclear Information System (INIS)

    Gast, R.C.

    1981-08-01

    A procedure for defining diffusion coefficients from Monte Carlo calculations that results in suitable ones for use in neutron diffusion theory calculations is not readily obtained. This study provides a survey of the methods used to define diffusion coefficients from deterministic calculations and provides a discussion as to why such traditional methods cannot be used in Monte Carlo. This study further provides the empirical procedure used for defining diffusion coefficients from the RCP01 Monte Carlo program

  1. Changes on diffusion-weighted MRI with focal motor status epilepticus: case report

    International Nuclear Information System (INIS)

    Loevblad, K.O.; Senn, P.; Zutter, D.; Bassetti, C.; Donati, F.; Loevblad, K.O.; Zeller, O.; Schroth, G.

    2003-01-01

    Transient imaging abnormalities, including changes on diffusion-weighted imaging (DWI), may be seen in focal status epilepticus. The changes on DWI provide an insight into the pathophysiology. We report a 53-year-old man with focal motor status epilepticus involving the left hand, arm and face with focal slowing on EEG. The apparent diffusion coefficients (ADC) were higher in the affected hemisphere than on the other side. At 10 days and 6 weeks after the end of the seizures, we saw normal ADCs and atrophy of the affected hemisphere. We conclude that the MRI findings indicate both cytotoxic and vasogenic oedema during seizure activity and subsequent loss of brain parenchyma. (orig.)

  2. Changes on diffusion-weighted MRI with focal motor status epilepticus: case report

    Energy Technology Data Exchange (ETDEWEB)

    Loevblad, K O [Neuroradiology, Radiodiagnostic, Hopital Cantonal de Geneve HUG, Geneve (Switzerland); Senn, P; Zutter, D; Bassetti, C; Donati, F [Dept. of Neurology, Inselspital, Univ. Hospital, Berne (Switzerland); Loevblad, K O; Zeller, O; Schroth, G [Div. of Neuroradiology, Inselspital, Univ. Hospital, Berne (Switzerland)

    2003-04-01

    Transient imaging abnormalities, including changes on diffusion-weighted imaging (DWI), may be seen in focal status epilepticus. The changes on DWI provide an insight into the pathophysiology. We report a 53-year-old man with focal motor status epilepticus involving the left hand, arm and face with focal slowing on EEG. The apparent diffusion coefficients (ADC) were higher in the affected hemisphere than on the other side. At 10 days and 6 weeks after the end of the seizures, we saw normal ADCs and atrophy of the affected hemisphere. We conclude that the MRI findings indicate both cytotoxic and vasogenic oedema during seizure activity and subsequent loss of brain parenchyma. (orig.)

  3. White matter biomarkers from diffusion MRI

    DEFF Research Database (Denmark)

    Jespersen, Sune

    2018-01-01

    Abstract As part of an issue celebrating 2 decades of Joseph Ackerman editing the Journal of Magnetic Resonance, this paper reviews recent progress in one of the many areas in which Ackerman and his lab has made significant contributions: NMR measurement of diffusion in biological media, specific...

  4. Diffusion of helium and estimated diffusion coefficients of hydrogen dissolved in water-saturated, compacted Ca-montmorillonite

    International Nuclear Information System (INIS)

    Higashihara, Tomohiro; Sato, Seichi; Ohashi, Hiroshi; Otsuka, Teppei

    2001-01-01

    The diffusion coefficients of hydrogen gas dissolved in water-saturated, compacted montmorillonite are required to estimate the performance of bentonite buffer materials for geological disposal of nuclear waste. As part of the effort to determine the diffusion coefficients, the diffusion coefficients of helium in water-saturated, compacted calcium montmorillonite (Ca-montmorillonite) were determined as a function of dry density, 0.78 to 1.37x10 3 kg m -3 , by a transient diffusion method. The diffusion coefficients were from 8.3x10 -10 m 2 s -1 at 0.78x10 3 kgm -3 to 2.8x10 -10 m 2 s -1 at 1.37x10 3 kgm -3 . The data obtained by this diffusion experiment of helium were highly reproducible. The diffusion coefficients of helium in Ca-montmorillonite were somewhat larger than those previously obtained for helium in sodium montmorillonite (Na-montmorillonite). The diffusion coefficients of hydrogen gas in the montmorillonites were roughly estimated using the diffusion coefficients of helium. These estimates were based on assumptions that both helium and hydrogen molecules are non-adsorptive and that the geometric factors in the compacted montmorillonites are approximately the same for diffusion of helium and diffusion of hydrogen. (author)

  5. Image quality transfer and applications in diffusion MRI

    DEFF Research Database (Denmark)

    Alexander, Daniel C.; Zikic, Darko; Ghosh, Aurobrata

    2017-01-01

    and the uniquely rich diffusion MRI data set from the human connectome project (HCP). Results highlight potential benefits of IQT in both brain connectivity mapping and microstructure imaging. In brain connectivity mapping, IQT reveals, from standard data sets, thin connection pathways that tractography normally...

  6. Cumulant expansions for measuring water exchange using diffusion MRI

    Science.gov (United States)

    Ning, Lipeng; Nilsson, Markus; Lasič, Samo; Westin, Carl-Fredrik; Rathi, Yogesh

    2018-02-01

    The rate of water exchange across cell membranes is a parameter of biological interest and can be measured by diffusion magnetic resonance imaging (dMRI). In this work, we investigate a stochastic model for the diffusion-and-exchange of water molecules. This model provides a general solution for the temporal evolution of dMRI signal using any type of gradient waveform, thereby generalizing the signal expressions for the Kärger model. Moreover, we also derive a general nth order cumulant expansion of the dMRI signal accounting for water exchange, which has not been explored in earlier studies. Based on this analytical expression, we compute the cumulant expansion for dMRI signals for the special case of single diffusion encoding (SDE) and double diffusion encoding (DDE) sequences. Our results provide a theoretical guideline on optimizing experimental parameters for SDE and DDE sequences, respectively. Moreover, we show that DDE signals are more sensitive to water exchange at short-time scale but provide less attenuation at long-time scale than SDE signals. Our theoretical analysis is also validated using Monte Carlo simulations on synthetic structures.

  7. Repeated diffusion MRI reveals earliest time point for stratification of radiotherapy response in brain metastases

    DEFF Research Database (Denmark)

    Mahmood, Faisal; Johannesen, Helle H; Geertsen, Poul

    2017-01-01

    An imaging biomarker for early prediction of treatment response potentially provides a non-invasive tool for better prognostics and individualized management of the disease. Radiotherapy (RT) response is generally related to changes in gross tumor volume manifesting months later. In this prospect......An imaging biomarker for early prediction of treatment response potentially provides a non-invasive tool for better prognostics and individualized management of the disease. Radiotherapy (RT) response is generally related to changes in gross tumor volume manifesting months later....... In this prospective study we investigated the apparent diffusion coefficient (ADC), perfusion fraction and pseudo diffusion coefficient derived from diffusion weighted MRI as potential early biomarkers for radiotherapy response of brain metastases. It was a particular aim to assess the optimal time point...

  8. Effective diffusion coefficient of radon in concrete, theory and method for field measurements

    International Nuclear Information System (INIS)

    Culot, M.V.J.; Olson, H.G.; Schiager, K.J.

    1976-01-01

    A linear diffusion model serves as the basis for determination of an effective radon diffusion coefficient in concrete. The coefficient was needed to later allow quantitative prediction of radon accumulation within and behind concrete walls after application of an impervious radon barrier. A resolution of certain discrepancies noted in the literature in the use of an effective diffusion coefficient to model diffusion of a radioactive gas through a porous medium is suggested. An outline of factors expected to affect the concrete physical structure and the effective diffusion coefficient of radon through it is also presented. Finally, a field method for evaluating effective radon diffusion coefficients in concrete is proposed and results of measurements performed on a concrete foundation wall are compared with similar published values of gas diffusion coefficients in concrete. (author)

  9. Dipy, a library for the analysis of diffusion MRI data

    Directory of Open Access Journals (Sweden)

    Eleftherios eGaryfallidis

    2014-02-01

    Full Text Available Diffusion Imaging in Python (Dipy is a free and open source software projectfor the analysis of data from diffusion magnetic resonance imaging (dMRIexperiments. dMRI is an application of MRI that can be used to measurestructural features of brain white matter. Many methods have been developed touse dMRI data to model the local configuration of white matter nerve fiberbundles and infer the trajectory of bundles connecting different parts of thebrain.Dipy gathers implementations of many different methods in dMRI, including:diffusion signal pre-processing; reconstruction of diffusion distributions inindividual voxels; fiber tractography and fiber track post-processing, analysisand visualization. Dipy aims to provide transparent implementations forall the different steps of dMRI analysis with a uniform programming interface.We have implemented classical signal reconstruction techniques, such as thediffusion tensor model and deterministic fiber tractography. In addition,cutting edge novel reconstruction techniques are implemented, such asconstrained spherical deconvolution and diffusion spectrum imaging withdeconvolution, as well as methods for probabilistic tracking and originalmethods for tractography clustering. Many additional utility functions areprovided to calculate various statistics, informative visualizations, as wellas file-handling routines to assist in the development and use of noveltechniques.In contrast to many other scientific software projects, Dipy is not beingdeveloped by a single research group. Rather, it is an open project thatencourages contributions from any scientist/developer through GitHub and opendiscussions on the project mailing list. Consequently, Dipy today has aninternational team of contributors, spanning seven different academic institutionsin five countries and three continents, which is still growing.

  10. Quantifying brain microstructure with diffusion MRI

    DEFF Research Database (Denmark)

    Novikov, Dmitry S.; Jespersen, Sune N.; Kiselev, Valerij G.

    2016-01-01

    the potential to quantify the relevant length scales for neuronal tissue, such as the packing correlation length for neuronal fibers, the degree of neuronal beading, and compartment sizes. The second avenue corresponds to the long-time limit, when the observed signal can be approximated as a sum of multiple non......-exchanging anisotropic Gaussian components. Here the challenge lies in parameter estimation and in resolving its hidden degeneracies. The third avenue employs multiple diffusion encoding techniques, able to access information not contained in the conventional diffusion propagator. We conclude with our outlook...... on the future research directions which can open exciting possibilities for developing markers of pathology and development based on methods of studying mesoscopic transport in disordered systems....

  11. Diffusion MRI: Mitigation of Magnetic Field Inhomogeneities

    Czech Academy of Sciences Publication Activity Database

    Marcon, P.; Bartušek, Karel; Dokoupil, Zdeněk; Gescheidtová, E.

    2012-01-01

    Roč. 12, č. 5 (2012), s. 205-212 ISSN 1335-8871 R&D Projects: GA MŠk ED0017/01/01; GA ČR GAP102/11/0318; GA ČR GAP102/12/1104 Institutional support: RVO:68081731 Keywords : correction * diffusion * inhomogeneity * eddy currents * magnetic resonance Subject RIV: JA - Electronics ; Optoelectronics, Electrical Engineering Impact factor: 1.233, year: 2012

  12. Correlation between 3 T apparent diffusion coefficient values and grading of invasive breast carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Cipolla, Valentina, E-mail: valentina.cipolla@yahoo.it [Department of Radiological Sciences, University of Rome “Sapienza”, Viale del Policlinico 155, 00161 Rome (Italy); Santucci, Domiziana; Guerrieri, Daniele; Drudi, Francesco Maria [Department of Radiological Sciences, University of Rome “Sapienza”, Viale del Policlinico 155, 00161 Rome (Italy); Meggiorini, Maria Letizia [Department of Gynaecological Sciences, University of Rome “Sapienza”, Viale del Policlinico 155, 00161 Rome (Italy); Felice, Carlo de [Department of Radiological Sciences, University of Rome “Sapienza”, Viale del Policlinico 155, 00161 Rome (Italy)

    2014-12-15

    Highlights: • Apparent diffusion coefficient is a quantitative parameter which reflects molecular water movement. • Grading is an independent prognostic factor which correlates with other histopathological features. • Apparent diffusion coefficient values were significantly different between G1 and G3 classes. - Abstract: Purpose: The aim of this study was to evaluate whether the apparent diffusion coefficient (ADC) provided by 3.0 T (3 T) magnetic resonance diffusion-weighted imaging (DWI) varied according to the grading of invasive breast carcinoma. Materials and methods: A total of 92 patients with 96 invasive breast cancer lesions were enrolled; all had undergone 3 T magnetic resonance imaging (MRI) for local staging. All lesions were confirmed by histological analysis, and tumor grade was established according to the Nottingham Grading System (NGS). MRI included both dynamic contrast-enhanced and DWI sequences, and ADC value was calculated for each lesion. ADC values were compared with NGS classification using the Mann–Whitney U and the Kruskal–Wallis H tests. Grading was considered as a comprehensive prognostic factor, and Rho Spearman test was performed to determine correlation between grading and tumor size, hormonal receptor status, HER2 expression and Ki67 index. Pearson's Chi square test was carried out to compare grading with the other prognostic factors. Results: ADC values were significantly higher in G1 than in G3 tumors. No significant difference was observed when G1 and G3 were compared with G2. Tumor size, hormonal receptor status, HER2 expression and Ki67 index correlated significantly with grading but there was a significant difference only between G1 and G3 related to the ER and PR status, HER2 expression and Ki67 index. There was no statistically significant difference in lesion size between the two groups. Conclusion: ADC values obtained on 3 T DWI correlated with low-grade (G1) and high-grade (G3) invasive breast carcinoma. 3

  13. Apparent diffusion coefficient histogram analysis of neonatal hypoxic-ischemic encephalopathy

    International Nuclear Information System (INIS)

    Cauley, Keith A.; Filippi, Christopher G.

    2014-01-01

    Diffusion-weighted imaging is a valuable tool in the assessment of the neonatal brain, and changes in diffusion are seen in normal development as well as in pathological states such as hypoxic-ischemic encephalopathy (HIE). Various methods of quantitative assessment of diffusion values have been reported. Global ischemic injury occurring during the time of rapid developmental changes in brain myelination can complicate the imaging diagnosis of neonatal HIE. To compare a quantitative method of histographic analysis of brain apparent coefficient (ADC) maps to the qualitative interpretation of routine brain MR imaging studies. We correlate changes in diffusion values with gestational age in radiographically normal neonates, and we investigate the sensitivity of the method as a quantitative measure of hypoxic-ischemic encephalopathy. We reviewed all brain MRI studies from the neonatal intensive care unit (NICU) at our university medical center over a 4-year period to identify cases that were radiographically normal (23 cases) and those with diffuse, global hypoxic-ischemic encephalopathy (12 cases). We histographically displayed ADC values of a single brain slice at the level of the basal ganglia and correlated peak (s-sD av ) and lowest histogram values (s-sD lowest ) with gestational age. Normative s-sD av values correlated significantly with gestational age and declined linearly through the neonatal period (r 2 = 0.477, P av and s-sD lowest ADC values than were reflected in the normative distribution; several cases of HIE fell within a 95% confidence interval for normative studies, and one case demonstrated higher-than-normal s-sD av . Single-slice histographic display of ADC values is a rapid and clinically feasible method of quantitative analysis of diffusion. In this study normative values derived from consecutive neonates without radiographic evidence of ischemic injury are correlated with gestational age, declining linearly throughout the perinatal period. This

  14. Axon diameter mapping in crossing fibers with diffusion MRI

    DEFF Research Database (Denmark)

    Zhang, Hui; Dyrby, Tim B; Alexander, Daniel C

    2011-01-01

    This paper proposes a technique for a previously unaddressed problem, namely, mapping axon diameter in crossing fiber regions, using diffusion MRI. Direct measurement of tissue microstructure of this kind using diffusion MRI offers a new class of biomarkers that give more specific information about...... tissue than measures derived from diffusion tensor imaging. Most existing techniques for axon diameter mapping assume a single axon orientation in the tissue model, which limits their application to only the most coherently oriented brain white matter, such as the corpus callosum, where the single...... model to enable axon diameter mapping in voxels with crossing fibers. We show in simulation that the technique can provide robust axon diameter estimates in a two-fiber crossing with the crossing angle as small as 45 degrees. Using ex vivo imaging data, we further demonstrate the feasibility...

  15. A systematic determination of diffusion coefficients of trace elements in open and restricted diffusive layers used by the diffusive gradients in a thin film technique

    DEFF Research Database (Denmark)

    Shiva, Amir Houshang; Teasdale, Peter R.; Bennett, William W.

    2015-01-01

    A systematic comparison of the diffusion coefficients of cations (Al, Cd, Co, Cu, Mn, Ni, Pb, Zn) and oxyanions (Al, As, Mo, Sb, V, W) in open (ODL) and restricted (RDL) diffusive layers used by the DGT technique was undertaken. Diffusion coefficients were measured using both the diffusion cell...... concentrations required with the Dcell measurements. This is the first time that D values have been reported for several oxyanions using RDL. Except for Al at pH 8.30 with ODL, all DDGT measurements were retarded relative to diffusion coefficients in water (DW) for both diffusive hydrogels. Diffusion in RDL...

  16. MRI findings in acute diffuse axonal injured patients

    International Nuclear Information System (INIS)

    Sato, Hidetaka

    2001-01-01

    Diffuse axonal injury (DAI) in the acute stage was clinically evaluated using magnetic resonance imaging (MRI), which is considered superior to computed tomography (CT) in detecting parenchymal brain lesions. MRI was disadvantageous, however, to patients suffering from acute severe head injury because of the long time required to construct imaging and unstable patient vital signs. We conducted MRI safely under a high magnetic field (1.5 tesla) in acute DAI by close observation and with nonmagnetic respirator and electrocardiographic monitoring. MRI was conducted in 95 patients diagnosed with DAI classified into mild (14), moderate (17) and severe (64) DAI by criteria established by Gennarelli (1986). In patients with mild or moderate DAI, CT revealed no lesion in the parenchymal area although MRI detected lesions in every case, mainly in cortical white matter or basal ganglia. In patients with severe DAI, CT revealed parenchymal lesions in 14 although MRI detected further lesions in cortical white matter, basal ganglia, corpus callosum and brainstem in every case. These results correspond well to the experimental model Gennarelli's. This study concluded that MRI was useful in assessing acute DAI patients. (author)

  17. Comparison of non-Gaussian and Gaussian diffusion models of diffusion weighted imaging of rectal cancer at 3.0 T MRI.

    Science.gov (United States)

    Zhang, Guangwen; Wang, Shuangshuang; Wen, Didi; Zhang, Jing; Wei, Xiaocheng; Ma, Wanling; Zhao, Weiwei; Wang, Mian; Wu, Guosheng; Zhang, Jinsong

    2016-12-09

    Water molecular diffusion in vivo tissue is much more complicated. We aimed to compare non-Gaussian diffusion models of diffusion-weighted imaging (DWI) including intra-voxel incoherent motion (IVIM), stretched-exponential model (SEM) and Gaussian diffusion model at 3.0 T MRI in patients with rectal cancer, and to determine the optimal model for investigating the water diffusion properties and characterization of rectal carcinoma. Fifty-nine consecutive patients with pathologically confirmed rectal adenocarcinoma underwent DWI with 16 b-values at a 3.0 T MRI system. DWI signals were fitted to the mono-exponential and non-Gaussian diffusion models (IVIM-mono, IVIM-bi and SEM) on primary tumor and adjacent normal rectal tissue. Parameters of standard apparent diffusion coefficient (ADC), slow- and fast-ADC, fraction of fast ADC (f), α value and distributed diffusion coefficient (DDC) were generated and compared between the tumor and normal tissues. The SEM exhibited the best fitting results of actual DWI signal in rectal cancer and the normal rectal wall (R 2  = 0.998, 0.999 respectively). The DDC achieved relatively high area under the curve (AUC = 0.980) in differentiating tumor from normal rectal wall. Non-Gaussian diffusion models could assess tissue properties more accurately than the ADC derived Gaussian diffusion model. SEM may be used as a potential optimal model for characterization of rectal cancer.

  18. Gene interference regulates aquaporin-4 expression in swollen tissue of rats with cerebral ischemic edema: Correlation with variation in apparent diffusion coefficient.

    Science.gov (United States)

    Hu, Hui; Lu, Hong; He, Zhanping; Han, Xiangjun; Chen, Jing; Tu, Rong

    2012-07-25

    To investigate the effects of mRNA interference on aquaporin-4 expression in swollen tissue of rats with ischemic cerebral edema, and diagnose the significance of diffusion-weighted MRI, we injected 5 μL shRNA- aquaporin-4 (control group) or siRNA- aquaporin-4 solution (1:800) (RNA interference group) into the rat right basal ganglia immediately before occlusion of the middle cerebral artery. At 0.25 hours after occlusion of the middle cerebral artery, diffusion-weighted MRI displayed a high signal; within 2 hours, the relative apparent diffusion coefficient decreased markedly, aquaporin-4 expression increased rapidly, and intracellular edema was obviously aggravated; at 4 and 6 hours, the relative apparent diffusion coefficient slowly returned to control levels, aquaporin-4 expression slightly increased, and angioedema was observed. In the RNA interference group, during 0.25-6 hours after injection of siRNA- aquaporin-4 solution, the relative apparent diffusion coefficient slightly fluctuated and aquaporin-4 expression was upregulated; during 0.5-4 hours, the relative apparent diffusion coefficient was significantly higher, while aquaporin-4 expression was significantly lower when compared with the control group, and intracellular edema was markedly reduced; at 0.25 and 6 hours, the relative apparent diffusion coefficient and aquaporin-4 expression were similar when compared with the control group; obvious angioedema remained at 6 hours. Pearson's correlation test results showed that aquaporin-4 expression was negatively correlated with the apparent diffusion coefficient (r = -0.806, P coefficient. Aquaporin-4 gene interference can effectively inhibit the upregulation of aquaporin-4 expression during the stage of intracellular edema with time-effectiveness. Moreover, diffusion-weighted MRI can accurately detect intracellular edema.

  19. Associations between apparent diffusion coefficient and electromyography parameters in myositis-A preliminary study.

    Science.gov (United States)

    Meyer, Hans-Jonas; Emmer, Alexander; Kornhuber, Malte; Surov, Alexey

    2018-05-01

    MRI is widely used in several muscle disorders. Diffusion-weighted imaging (DWI) is an emergent imaging modality sensitive to microstructural alterations in tissue. The apparent diffusion coefficient (ADC) is used to quantify the random motion of water molecules. Electromyography (EMG) is a clinically used diagnostic tool in myositis. The aim of this study was to elucidate possible associations between ADC values and EMG findings in myositis patients. Seven patients (eight investigated muscles) with myositis (mean age 51.43 ± 19 years) were included in this study. The diagnosis was confirmed by histopathology in every case. DWI was obtained with a 1.5-T scanner using two b-values 0 and 1000 s/mm². In all patients, a needle electromyography (EMG) was performed within 3 days to the MRI. The following EMG parameters were studied: motor unit action potential (MUAP) amplitudes and durations, as well as pathological spontaneous activity. Spearman's correlation coefficient was used to analyze associations between investigated parameters. The estimated mean ADC mean value was 1.51 ± 0.29 × 10 -3  mm²/s, mean ADC min was 1.28 ± 0.27 × 10 -3  mm²/s, and mean ADC max was 1.73 ± 0.28 × 10 -3  mm²/s. Correlation analysis identified significant associations between ADC mean and duration of the MUAP (p   = .78 P = .0279) and between ADC min and duration of the MUAP (p = .85, P = .01). There were no significant differences according to pathological spontaneous activity. ADC mean and ADC min showed strong positive correlations with the duration of the MUAP in myositis patients. Both modalities might similarly reflect muscle fiber loss in myositis patients.

  20. Discrimination of paediatric brain tumours using apparent diffusion coefficient histograms

    International Nuclear Information System (INIS)

    Bull, Jonathan G.; Clark, Christopher A.; Saunders, Dawn E.

    2012-01-01

    To determine if histograms of apparent diffusion coefficients (ADC) can be used to differentiate paediatric brain tumours. Imaging of histologically confirmed tumours with pre-operative ADC maps were reviewed (54 cases, 32 male, mean age 6.1 years; range 0.1-15.8 years) comprising 6 groups. Whole tumour ADC histograms were calculated; normalised for volume. Stepwise logistic regression analysis was used to differentiate tumour types using histogram metrics, initially for all groups and then for specific subsets. All 6 groups (5 dysembryoplastic neuroectodermal tumours, 22 primitive neuroectodermal tumours (PNET), 5 ependymomas, 7 choroid plexus papillomas, 4 atypical teratoid rhabdoid tumours (ATRT) and 9 juvenile pilocytic astrocytomas (JPA)) were compared. 74% (40/54) were correctly classified using logistic regression of ADC histogram parameters. In the analysis of posterior fossa tumours, 80% of ependymomas, 100% of astrocytomas and 94% of PNET-medulloblastoma were classified correctly. All PNETs were discriminated from ATRTs (22 PNET and 4 supratentorial ATRTs) (100%). ADC histograms are useful in differentiating paediatric brain tumours, in particular, the common posterior fossa tumours of childhood. PNETs were differentiated from supratentorial ATRTs, in all cases, which has important implications in terms of clinical management. (orig.)

  1. Quantitative differentiation of breast lesions at 3T diffusion-weighted imaging (DWI) using the ratio of distributed diffusion coefficient (DDC).

    Science.gov (United States)

    Ertas, Gokhan; Onaygil, Can; Akin, Yasin; Kaya, Handan; Aribal, Erkin

    2016-12-01

    To investigate the accuracy of diffusion coefficients and diffusion coefficient ratios of breast lesions and of glandular breast tissue from mono- and stretched-exponential models for quantitative diagnosis in diffusion-weighted magnetic resonance imaging (MRI). We analyzed pathologically confirmed 170 lesions (85 benign and 85 malignant) imaged using a 3.0T MR scanner. Small regions of interest (ROIs) focusing on the highest signal intensity for lesions and also for glandular tissue of contralateral breast were obtained. Apparent diffusion coefficient (ADC) and distributed diffusion coefficient (DDC) were estimated by performing nonlinear fittings using mono- and stretched-exponential models, respectively. Coefficient ratios were calculated by dividing the lesion coefficient by the glandular tissue coefficient. A stretched exponential model provides significantly better fits then the monoexponential model (P DDC ratio (area under the curve [AUC] = 0.93) when compared with lesion DDC, ADC ratio, and lesion ADC (AUC = 0.91, 0.90, 0.90) but with no statistically significant difference (P > 0.05). At optimal thresholds, the DDC ratio achieves 93% sensitivity, 80% specificity, and 87% overall diagnostic accuracy, while ADC ratio leads to 89% sensitivity, 78% specificity, and 83% overall diagnostic accuracy. The stretched exponential model fits better with signal intensity measurements from both lesion and glandular tissue ROIs. Although the DDC ratio estimated by using the model shows a higher diagnostic accuracy than the ADC ratio, lesion DDC, and ADC, it is not statistically significant. J. Magn. Reson. Imaging 2016;44:1633-1641. © 2016 International Society for Magnetic Resonance in Medicine.

  2. Hepatic hemangioma: Correlation of enhancement types with diffusion-weighted MR findings and apparent diffusion coefficients

    Energy Technology Data Exchange (ETDEWEB)

    Goshima, Satoshi [Department of Radiology, Gifu University Hospital, 1-1 Yanagido, Gifu 501-1194 (Japan)], E-mail: gossy@par.odn.ne.jp; Kanematsu, Masayuki [Department of Radiology, Gifu University Hospital, 1-1 Yanagido, Gifu 501-1194 (Japan); Department of Radiology Services, Gifu University Hospital, 1-1 Yanagido, Gifu 501-1194 (Japan); Kondo, Hiroshi [Department of Radiology, Gifu University Hospital, 1-1 Yanagido, Gifu 501-1194 (Japan); Yokoyama, Ryujiro; Kajita, Kimihiro [Department of Radiology Services, Gifu University Hospital, 1-1 Yanagido, Gifu 501-1194 (Japan); Tsuge, Yusuke [Department of Radiology, Gifu University Hospital, 1-1 Yanagido, Gifu 501-1194 (Japan); Shiratori, Yoshimune [Department of Medical Informatics, Gifu University School of Medicine, Gifu (Japan); Onozuka, Minoru [Department of Physiology and Neuroscience, Kanagawa Dental College, Yokosuka (Japan); Moriyama, Noriyuki [Research Center for Cancer Prevention and Screening, National Cancer Center Hospital, Tsukiji (Japan)

    2009-05-15

    Purpose: To correlate hepatic hemangioma enhancement types in gadolinium-enhanced magnetic resonance (MR) images with diffusion-weighted MR findings and apparent diffusion coefficients (ADCs). Materials and methods: Respiratory-triggered diffusion-weighted MR images (TR/TE, 2422/46 ms; parallel imaging factor, 2; b factor, 500 s/mm{sup 2}; number of averaging, 6) obtained in 35 patients with 44 hepatic hemangiomas diagnosed by gadolinium-enhanced MR and by follow-up imaging were retrospectively evaluated. Hemangiomas were classified into three enhancement types based on gadolinium-enhanced MR imaging findings: type I, early-enhancement type; type II, peripheral nodular enhancement type; type III, delayed enhancement type. Two blinded readers qualitatively assessed lesion sizes and signal intensities on T2-weighted turbo spin-echo and diffusion-weighted images. The ADCs of hemangiomas were also measured. Results: No significant difference was observed between the three enhancement types in terms of signal intensities on T2-weighted images. Signal intensities on diffusion-weighted images were lower in the order type I to III (P < .01), and mean ADCs were 2.18 x 10{sup -3}, 1.86 x 10{sup -3}, and 1.71 x 10{sup -3} mm{sup 2}/s for types I, II, and III, respectively (P < .01). No correlation was found between lesion sizes and ADCs. Conclusion: Hepatic hemangiomas were found to have enhancement type dependent signal intensities and ADCs on diffusion-weighted MR images. Further studies will have to substantiate that these diffusion patterns might reflect intratumoral blood flow or perfusion.

  3. Differentiation of prostate cancer lesions with high and with low Gleason score by diffusion-weighted MRI

    Energy Technology Data Exchange (ETDEWEB)

    Barbieri, Sebastiano; Broennimann, Michael; Vermathen, Peter; Thoeny, Harriet C. [Inselspital University Hospital, Institute of Diagnostic, Pediatric, and Interventional Radiology, Bern (Switzerland); Boxler, Silvan [Inselspital, Inselspital University Hospital, Department of Urology, Bern (Switzerland)

    2017-04-15

    To differentiate prostate cancer lesions with high and with low Gleason score by diffusion-weighted-MRI (DW-MRI). This prospective study was approved by the responsible ethics committee. DW-MRI of 84 consenting prostate and/or bladder cancer patients scheduled for radical prostatectomy were acquired and used to compute apparent diffusion coefficient (ADC), intravoxel incoherent motion (IVIM: the pure diffusion coefficient D{sub t}, the pseudo-diffusion fraction F{sub p} and the pseudo-diffusion coefficient D{sub p}), and high b value (as acquired and Hessian filtered) parameters within the index lesion. These parameters (separately and combined in a logistic regression model) were used to differentiate lesions depending on whether whole-prostate histopathological analysis after prostatectomy determined a high (≥7) or low (6) Gleason score. Mean ADC and D{sub t} differed significantly (p of independent two-sample t test < 0.01) between high- and low-grade lesions. The highest classification accuracy was achieved by the mean ADC (AUC 0.74) and D{sub t} (AUC 0.70). A logistic regression model based on mean ADC, mean F{sub p} and mean high b value image led to an AUC of 0.74 following leave-one-out cross-validation. Classification by IVIM parameters was not superior to classification by ADC. DW-MRI parameters correlated with Gleason score but did not provide sufficient information to classify individual patients. (orig.)

  4. Diffusion-weighted magnetic resonance imaging with apparent diffusion coefficient (ADC) determination in normal and pathological fetal kidneys.

    Science.gov (United States)

    Chaumoitre, K; Colavolpe, N; Shojai, R; Sarran, A; D' Ercole, C; Panuel, M

    2007-01-01

    To assess the use of diffusion-weighted magnetic resonance imaging (DW-MRI) in the evaluation of the fetal kidney and to estimate age-dependent changes in the apparent diffusion coefficient (ADC) of normal and pathological fetal kidneys. DW-MRI was performed on a 1.5-T machine at 23-38 gestational weeks in 51 pregnant women in whom the fetal kidneys were normal and in 10 whose fetuses had renal pathology (three with suspected nephropathy, three with renal tract dilatation, one with unilateral renal venous thrombosis, and three with twin-twin transfusion syndrome (TTTS)). The ADC was measured in an approximately 1-cm2 region of interest within the renal parenchyma. ADC values in normal renal parenchyma ranged from 1.1 to 1.8 10(-3) mm2 s-1. There was no significant age-dependent change in the ADC of normal kidneys. In cases of nephropathy, the ADC value was not always pathological but an ADC map could show abnormal findings. In cases of dilatation, the ADC value was difficult to determine when the dilatation was huge. In cases of TTTS, the ADC of the donor twin was higher than that of the recipient twin and the difference seemed to be related to the severity of the syndrome. Evaluation of the ADC for fetal kidneys is feasible. Fetal measurement of the ADC value and ADC maps may be useful tools with which to explore the fetal kidney when used in conjunction with current methods. DW-MR images, ADC value and ADC map seem to be useful in cases of suspected nephropathy (hyperechoic kidneys), dilated kidney and vascular pathology (renal venous thrombosis, TTTS). Copyright (c) 2006 ISUOG.

  5. Role of PROPELLER diffusion weighted imaging and apparent diffusion coefficient in the diagnosis of sellar and parasellar lesions

    Energy Technology Data Exchange (ETDEWEB)

    Mahmoud, Omar M., E-mail: omarmostafa2008@yahoo.co [Department of Neurosurgery, Graduate School of Biomedical Science, Hiroshima University, 1-2-3 Kasumi, Minami-ku, Hiroshima 734-8551 (Japan); Department of Radiology, South Egypt Cancer Institute, Assiut University, Assiut 71515 (Egypt); Tominaga, Atsushi, E-mail: atom@hiroshima-u.ac.j [Department of Neurosurgery, Graduate School of Biomedical Science, Hiroshima University, 1-2-3 Kasumi, Minami-ku, Hiroshima 734-8551 (Japan); Amatya, Vishwa Jeet, E-mail: amatya@hiroshima-u.ac.j [Department of Pathology, Graduate School of Biomedical Sciences, Hiroshima University, Hiroshima 734-8551 (Japan); Ohtaki, Megu, E-mail: ohtaki@hiroshima-u.ac.j [Department of Environmetrics and Biometrics, Research Institute for Radiation Biology and Medicine, Hiroshima University, Hiroshima 734-8551 (Japan); Sugiyama, Kazuhiko, E-mail: brain@hiroshima-u.ac.j [Department of Neurosurgery, Graduate School of Biomedical Science, Hiroshima University, 1-2-3 Kasumi, Minami-ku, Hiroshima 734-8551 (Japan); Saito, Taiichi, E-mail: taiichi@hiroshima-u.ac.j [Department of Neurosurgery, Graduate School of Biomedical Science, Hiroshima University, 1-2-3 Kasumi, Minami-ku, Hiroshima 734-8551 (Japan); Sakoguchi, Tetsuhiko, E-mail: sakog@hiroshima-u.ac.j [Department of Neurosurgery, Graduate School of Biomedical Science, Hiroshima University, 1-2-3 Kasumi, Minami-ku, Hiroshima 734-8551 (Japan); Kinoshita, Yasuyuki, E-mail: d055634@hiroshima-u.ac.j [Department of Neurosurgery, Graduate School of Biomedical Science, Hiroshima University, 1-2-3 Kasumi, Minami-ku, Hiroshima 734-8551 (Japan); Shrestha, Prabin, E-mail: prabinshrestha@hotmail.co [Department of Neurosurgery, Graduate School of Biomedical Science, Hiroshima University, 1-2-3 Kasumi, Minami-ku, Hiroshima 734-8551 (Japan); Abe, Nobukazu, E-mail: abebe@hiroshima-u.ac.j [Dept. of Clinical Radiology, Graduate School of Biomedical Sciences, Hiroshima Univ., Hiroshima 734-8551 (Japan)

    2010-06-15

    Objective: To evaluate the role of the apparent diffusion coefficient (ADC) using periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER) diffusion weighted imaging (DWI) in the differentiation between sellar and parasellar mass lesions. Materials and methods: The study protocol was approved by our institutional review board. We retrospectively studied 60 patients with sellar and parasellar lesions who had undergone PROPELLER DWI on a 3-T MR imager. Conventional MRI findings were expressed as the ratio of signal intensity (SI) in the lesions to the normal white matter and the degree of contrast enhancement. ADC values were calculated as the minimum (ADC-MIN), mean (ADC-MEAN), and maximum (ADC-MAX). All patients underwent surgery and all specimens were examined histologically. Logistic discriminant analysis was performed by using the SI ratios on T1- and T2-weighted images (T1-WI, T2-WI), the degree of enhancement, and absolute ADC values as independent variables. Results: ADC-MIN of hemorrhagic pituitary adenomas was lower than of the other lesions with similar appearance on conventional MRI (non-hemorrhagic pituitary adenomas, craniopharyngiomas, Rathke's cleft cysts; accuracy 100%); the useful cut-off value was 0.700 x 10{sup -3} mm{sup 2}/s. ADC-MAX of meningiomas was lower than of non-hemorrhagic pituitary adenomas (accuracy 90.3%; p < 0.01). ADC-MIN of craniopharyngiomas was lower than of Rathke's cleft cysts (accuracy 100%; p < 0.05). Conclusion: As PROPELLER DWI is less sensitive to susceptibility artifacts than single-shot echoplanar DWI, it is more useful in the examination of sellar and parasellar lesions. Calculation of the ADC values helps to differentiate between various sellar and parasellar lesions.

  6. Role of PROPELLER diffusion weighted imaging and apparent diffusion coefficient in the diagnosis of sellar and parasellar lesions

    International Nuclear Information System (INIS)

    Mahmoud, Omar M.; Tominaga, Atsushi; Amatya, Vishwa Jeet; Ohtaki, Megu; Sugiyama, Kazuhiko; Saito, Taiichi; Sakoguchi, Tetsuhiko; Kinoshita, Yasuyuki; Shrestha, Prabin; Abe, Nobukazu

    2010-01-01

    Objective: To evaluate the role of the apparent diffusion coefficient (ADC) using periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER) diffusion weighted imaging (DWI) in the differentiation between sellar and parasellar mass lesions. Materials and methods: The study protocol was approved by our institutional review board. We retrospectively studied 60 patients with sellar and parasellar lesions who had undergone PROPELLER DWI on a 3-T MR imager. Conventional MRI findings were expressed as the ratio of signal intensity (SI) in the lesions to the normal white matter and the degree of contrast enhancement. ADC values were calculated as the minimum (ADC-MIN), mean (ADC-MEAN), and maximum (ADC-MAX). All patients underwent surgery and all specimens were examined histologically. Logistic discriminant analysis was performed by using the SI ratios on T1- and T2-weighted images (T1-WI, T2-WI), the degree of enhancement, and absolute ADC values as independent variables. Results: ADC-MIN of hemorrhagic pituitary adenomas was lower than of the other lesions with similar appearance on conventional MRI (non-hemorrhagic pituitary adenomas, craniopharyngiomas, Rathke's cleft cysts; accuracy 100%); the useful cut-off value was 0.700 x 10 -3 mm 2 /s. ADC-MAX of meningiomas was lower than of non-hemorrhagic pituitary adenomas (accuracy 90.3%; p < 0.01). ADC-MIN of craniopharyngiomas was lower than of Rathke's cleft cysts (accuracy 100%; p < 0.05). Conclusion: As PROPELLER DWI is less sensitive to susceptibility artifacts than single-shot echoplanar DWI, it is more useful in the examination of sellar and parasellar lesions. Calculation of the ADC values helps to differentiate between various sellar and parasellar lesions.

  7. Early Changes in Apparent Diffusion Coefficient From Diffusion-Weighted MR Imaging During Radiotherapy for Prostate Cancer

    International Nuclear Information System (INIS)

    Park, Sung Yoon; Kim, Chan Kyo; Park, Byung Kwan; Park, Won; Park, Hee Chul; Han, Deok Hyun; Kim, Bohyun

    2012-01-01

    Purpose: To investigate the feasibility of diffusion-weighted MRI (DWI) as an early and reproducible change indicator in patients receiving radiotherapy for prostate cancer (PC). Methods and Materials: Eight consecutive patients with biopsy-proven PC underwent DWI at 3T. All patients who received external-beam radiotherapy had four serial MR scans, as follows: before therapy (PreTx); after 1 week of therapy (PostT1); after 3 weeks of therapy (PostT2); and 1 month after the completion of therapy (PostT3). At each time, the apparent diffusion coefficient (ADC) was measured in tumors and normal tissues. For reproducibility of the ADC measurement, five patients also had two separate pretreatment DWI scans at an interval of −3 mm 2 /s in sequence, respectively. Compared with PreTx, PostT1 (p = 0.005), PostT2 (p = 0.003), and PostT3 (p −3 mm 2 /s in sequence, respectively. Reproducibility of ADC measurements was confirmed with a mean difference in ADC of –0.04 in peripheral zone and –0.017 in transition zone between two separate pretreatment MR scans. The mean PSA levels from PreTx to PostT3 were 9.05, 9.18, 9.25, and 4.11 ng/mL in sequence, respectively. Conclusions: DWI, as a reproducible biomarker, has the potential to evaluate the early therapeutic changes of PC to radiotherapy.

  8. Correlation between apparent diffusion coefficient value on diffusion-weighted MR imaging and Gleason score in prostate cancer.

    Science.gov (United States)

    Wu, X; Reinikainen, P; Vanhanen, A; Kapanen, M; Vierikko, T; Ryymin, P; Hyödynmaa, S; Kellokumpu-Lehtinen, P-L

    2017-01-01

    To investigate whether diffusion-weighted imaging (DWI) apparent diffusion coefficient (ADC) correlates with prostate cancer aggressiveness and further to compare the diagnostic performance of ADC and normalized ADC (nADC: normalized to non-tumor tissue). Thirty pre-treatment patients (mean age, 69years; range: 59-78years) with prostate cancer underwent magnetic resonance imaging (MRI) examination, including DWI with three b values: 50, 400, and 800s/mm 2 . Both ADC and nADC were correlated with the Gleason score obtained through transrectal ultrasound-guided biopsy. The tumor minimum ADC (ADC min : the lowest ADC value within tumor) had an inverse correlation with the Gleason score (r=-0.43, Pcorrelated with the Gleason score (r=-0.52 and r=-0.55, P<0.01; respectively), and they were lower in patients with Gleason score 3+4 than those with Gleason score 3+3 (P<0.01; respectively). Receiver operating characteristic (ROC) analysis showed that the area under the ROC curve was 0.765, 0.818, or 0.833 for the ADC min , nADC min , or nADC mean ; respectively, in differentiating between Gleason score 3+4 and 3+3 tumors. Tumor ADC min , nADC min , and nADC mean are useful markers to predict the aggressiveness of prostate cancer. Copyright © 2016 Éditions françaises de radiologie. Published by Elsevier Masson SAS. All rights reserved.

  9. Diffuse axonal injury at ultra-high field MRI.

    Directory of Open Access Journals (Sweden)

    Christoph Moenninghoff

    Full Text Available Diffuse axonal injury (DAI is a specific type of traumatic brain injury caused by shearing forces leading to widespread tearing of axons and small vessels. Traumatic microbleeds (TMBs are regarded as a radiological marker for DAI. This study aims to compare DAI-associated TMBs at 3 Tesla (T and 7 T susceptibility weighted imaging (SWI to evaluate possible diagnostic benefits of ultra-high field (UHF MRI.10 study participants (4 male, 6 female, age range 20-74 years with known DAI were included. All MR exams were performed with a 3 T MR system (Magnetom Skyra and a 7 T MR research system (Magnetom 7 T, Siemens AG, Healthcare Sector, Erlangen, Germany each in combination with a 32-channel-receive coil. The average time interval between trauma and imaging was 22 months. Location and count of TMBs were independently evaluated by two neuroradiologists on 3 T and 7 T SWI images with similar and additionally increased spatial resolution at 7 T. Inter- and intraobserver reliability was assessed using the interclass correlation coefficient (ICC. Count and diameter of TMB were evaluated with Wilcoxon signed rank test.Susceptibility weighted imaging revealed a total of 485 TMBs (range 1-190, median 25 at 3 T, 584 TMBs (plus 20%, range 1-262, median 30.5 at 7 T with similar spatial resolution, and 684 TMBs (plus 41%, range 1-288, median 39.5 at 7 T with 10-times higher spatial resolution. Hemorrhagic DAI appeared significantly larger at 7 T compared to 3 T (p = 0.005. Inter- and intraobserver correlation regarding the counted TMB was high and almost equal 3 T and 7 T.7 T SWI improves the depiction of small hemorrhagic DAI compared to 3 T and may be supplementary to lower field strengths for diagnostic in inconclusive or medicolegal cases.

  10. Focal Pancreatitis Mimicking Pancreatic Mass: Magnetic Resonance Imaging (MRI)/Magnetic Resonance Cholangiopancreatography (MRCP) Findings Including Diffusion-Weighted MRI

    International Nuclear Information System (INIS)

    Momtahen, A.J.; Balci, N.C.; Alkaade, S.; Akduman, E.I.; Burton, F.R.

    2008-01-01

    Background: Focal pancreatitis (FP) is a confined inflammation that mimics a pancreatic mass. Its imaging diagnosis is important to avoid unnecessary procedures. Purpose: To describe the spectrum of magnetic resonance imaging (MRI)/magnetic resonance cholangiopancreatography (MRCP) and diffusion-weighted MRI (DWI) findings of focal pancreatitis mimicking pancreatic masses. Material and Methods: Findings of MRI/MRCP including DWI with a b value of 0 and 600 s/mm2 in 14 patients with pancreatic masses on MRI were retrospectively reviewed and compared to normal pancreas in 14 patients as a control group. Results: FP revealed hypointense signal intensity (SI) (3/14), hypo- to isointense SI (7/14), or isointense SI (4/14) on T1-weighted images, and hypointense SI (1/14), isointense SI (5/14), iso- to hyperintense SI (7/14), or hyperintense SI (1/14) on T2-weighted images compared to remaining pancreas (RP). MRCP images revealed dilatation of the common bile duct (CBD) and main pancreatic duct (MPD) (5/14), dilatation of the MPD only (3/14), dilatation of the CBD only (3/14), and normal MPD and CBD (3/14). Both FP and RP revealed three types of time-signal intensity curves: 1) rapid rise to a peak, with a rapid decline (FP=2, RP=4), 2) slow rise to a peak, followed by a slow decline (FP=5, RP=4), and 3) slower rise to a peak, with a slow decline or plateau (FP=7, RP=6). Mean apparent diffusion coefficient (ADC) values for FP and RP were 2.09±0.18 and 2.03±0.2x10 -3 mm 2 /s, respectively. ADC values of FP and RP revealed no significant difference. Conclusion: The spectrum of imaging findings of focal pancreatitis on MRI/MRCP including DWI was described. Findings of FP were not distinctive as compared to the remaining pancreas

  11. Relationship between pretreatment FDG-PET and diffusion-weighted MRI biomarkers in diffuse large B-cell lymphoma

    Science.gov (United States)

    de Jong, Antoinette; Kwee, Thomas C; de Klerk, John MH; Adam, Judit A; de Keizer, Bart; Fijnheer, Rob; Kersten, Marie José; Ludwig, Inge; Jauw, Yvonne WS; Zijlstra, Josée M; den Bos, Indra C Pieters - Van; Stoker, Jaap; Hoekstra, Otto S; Nievelstein, Rutger AJ

    2014-01-01

    The purpose of this study was to determine the correlation between the 18F-fluoro-2-deoxy-D-glucose positron emission tomography (FDG-PET) standardized uptake value (SUV) and the diffusion-weighted magnetic resonance imaging (MRI) apparent diffusion coefficient (ADC) in newly diagnosed diffuse large B-cell lymphoma (DLBCL). Pretreatment FDG-PET and diffusion-weighted MRI of 21 patients with histologically proven DLBCL were prospectively analyzed. In each patient, maximum, mean and peak standardized uptake value (SUV) was measured in the lesion with visually highest FDG uptake and in the largest lesion. Mean ADC (ADCmean, calculated with b-values of 0 and 1000 s/mm2) was measured in the same lesions. Correlations between FDG-PET metrics (SUVmax, SUVmean, SUVpeak) and ADCmean were assessed using Pearson’s correlation coefficients. In the lesions with visually highest FDG uptake, no significant correlations were found between the SUVmax, SUVmean, SUVpeak and the ADCmean (P=0.498, P=0.609 and P=0.595, respectively). In the largest lesions, there were no significant correlations either between the SUVmax, SUVmean, SUVpeak and the ADCmean (P=0.992, P=0.843 and P=0.894, respectively). The results of this study indicate that the glycolytic rate as measured by FDG-PET and changes in water compartmentalization and water diffusion as measured by the ADC are independent biological phenomena in newly diagnosed DLBCL. Further studies are warranted to assess the complementary roles of these different imaging biomarkers in the evaluation and follow-up of DLBCL. PMID:24795837

  12. Fast and direct detection of neuronal activation with diffusion MRI

    International Nuclear Information System (INIS)

    Le Bihan, D.; Urayama, S.; Aso, T.; Hanakawa, T.; Fukuyama, H.

    2006-01-01

    conditions or in the presence of drugs. Also, it has been pointed out that the spatial functional resolution of vascular based functional neuroimaging might be limited, because vessels responsible for the increase of blood flow and blood volume feed or drain somewhat large territories which include clusters of neurons with potentially different functions. Similarly the physiological delay necessary for the mechanisms triggering the vascular response to work intrinsically limits the temporal resolution of BOLD f MRI. On the other hand, a fundamentally new paradigm is being proposed to look at brain activity through the observation with MRI of the diffusion behavior of the water molecules. It has been shown that the diffusion of water slightly slows down during brain activation. This slowdown, which occurs several seconds before the hemodynamic response detected by BOLD f MRI, has been described in terms of a phase transition of the water molecules in the cells undergoing activation and tentatively attributed to the swelling of those cells. This finding marks a significant departure from the former blood flow based PET and MRI approaches, and potentially offers improved spatial and temporal resolution, because the proposed mechanism appears more intimately linked to neuronal activation. However, the step might even extend further: Contrarily to the former approaches based on changes in artificially induced water physical properties, namely radioactivity and magnetization, required for the external PET or MR I detection, the new, diffusion based approach, merely uses MRI as a means to reveal changes in intrinsic water physical properties. These changes in the diffusion behaviour of water during activation seem to belong to an endogenous part of the activation process, and perhaps even more, could be an active component of this process that evolution has capitalized upon. The aim of this presentation is to review our current knowledge on the water physical properties i n

  13. Evaluation of diffusion coefficients in multicomponent mixtures by means of the fluctuation theory

    DEFF Research Database (Denmark)

    Shapiro, Alexander

    2003-01-01

    We derive general expressions for diffusion coefficients in multicomponent non-ideal gas or liquid mixtures. The derivation is based on the general statistical theory of fluctuations around an equilibrium state. The matrix of diffusion coefficients is expressed in terms of the equilibrium...... characteristics. We demonstrate on several examples that the developed theory is in agreement with the established experimental facts and dependencies for the diffusion coefficients. (C) 2002 Elsevier Science B.V. All rights reserved....

  14. On time-dependent diffusion coefficients arising from stochastic processes with memory

    Science.gov (United States)

    Carpio-Bernido, M. Victoria; Barredo, Wilson I.; Bernido, Christopher C.

    2017-08-01

    Time-dependent diffusion coefficients arise from anomalous diffusion encountered in many physical systems such as protein transport in cells. We compare these coefficients with those arising from analysis of stochastic processes with memory that go beyond fractional Brownian motion. Facilitated by the Hida white noise functional integral approach, diffusion propagators or probability density functions (pdf) are obtained and shown to be solutions of modified diffusion equations with time-dependent diffusion coefficients. This should be useful in the study of complex transport processes.

  15. Solution of the atmospheric diffusion equation with a realistic diffusion coefficient and time dependent mixing height

    International Nuclear Information System (INIS)

    Mayhoub, A.B.; Etman, S.M.

    1997-01-01

    One dimensional model for the dispersion of a passive atmospheric contaminant (neglecting chemical reactions) in the atmospheric boundary layer is introduced. The differential equation representing the dispersion of pollutants is solved on the basis of gradient-transfer theory (K- theory). The present approach deals with a more appropriate and realistic profile for the diffusion coefficient K, which is expressed in terms of the friction velocity U, the vertical coordinate z and the depth of the mixing layer h, which is taken time dependent. After some mathematical simplification, the equation analytic obtained solution can be easily applied to case study concerning atmospheric dispersion of pollutants

  16. Diffusion-weighted MRI in shaken baby syndrome

    International Nuclear Information System (INIS)

    Chan, Yu-Leung; Chu, Winnie C.W.; Wong, Gary W.K.; Yeung, David K.W.

    2003-01-01

    We present the characteristic CT and MRI findings of a 2-month-old girl with shaken baby syndrome. Diffusion-weighted MR imaging performed 8 days after the insult established the presence of injury to the white matter in the corpus callosum and subcortical white matter in the temporo-occipito-parietal region. Diffusion-weighted MR imaging is valuable in the diagnostic work-up of suspected shaken baby syndrome, as injury to the white matter can be demonstrated days after the injury. (orig.)

  17. Short-term evolution of spinal cord damage in multiple sclerosis: a diffusion tensor MRI study

    Energy Technology Data Exchange (ETDEWEB)

    Theaudin, M.; Denier, C.; Adams, D. [AP-HP, CHU Bicetre, Service de Neurologie Adultes, Le Kremlin-Bicetre (France); INSERM, UMR788, Faculte de Medecine Paris Sud, Le Kremlin-Bicetre (France); Saliou, G. [AP-HP, CHU Bicetre, Service de Neuroradiologie, Le Kremlin-Bicetre (France); Ducot, B. [INSERM, U1018, CESP Centre for Research in Epidemiology and Population Health, Faculte de Medecine Paris Sud, Le Kremlin-Bicetre (France); Deiva, K. [Service de Neuropediatrie, Le Kremlin-Bicetre (France); Ducreux, D. [INSERM, UMR788, Faculte de Medecine Paris Sud, Le Kremlin-Bicetre (France); AP-HP, CHU Bicetre, Service de Neuroradiologie, Le Kremlin-Bicetre (France)

    2012-10-15

    The potential of diffusion tensor imaging (DTI) to detect spinal cord abnormalities in patients with multiple sclerosis has already been demonstrated. The objective of this study was to apply DTI techniques to multiple sclerosis patients with a recently diagnosed spinal cord lesion, in order to demonstrate a correlation between variations of DTI parameters and clinical outcome, and to try to identify DTI parameters predictive of outcome. A prospective single-centre study of patients with spinal cord relapse treated by intravenous steroid therapy was made. Patients were assessed clinically and by conventional MRI with DTI sequences at baseline and at 3 months. Sixteen patients were recruited. At 3 months, 12 patients were clinically improved. All but one patient had lower fractional anisotropy (FA) and apparent diffusion coefficient (ADC) values than normal subjects in either inflammatory lesions or normal-appearing spinal cord. Patients who improved at 3 months presented a significant reduction in the radial diffusivity (p = 0.05) in lesions during the follow-up period. They also had a significant reduction in the mean ADC (p = 0.002), axial diffusivity (p = 0.02), radial diffusivity (p = 0.02) and a significant increase in FA values (p = 0.02) in normal-appearing spinal cord. Patients in whom the American Spinal Injury Association sensory score improved at 3 months showed a significantly higher FA (p = 0.009) and lower radial diffusivity (p = 0.04) in inflammatory lesion at baseline compared to patients with no improvement. DTI MRI detects more extensive abnormalities than conventional T2 MRI. A less marked decrease in FA value and more marked decreased in radial diffusivity inside the inflammatory lesion were associated with better outcome. (orig.)

  18. Short-term evolution of spinal cord damage in multiple sclerosis: a diffusion tensor MRI study

    International Nuclear Information System (INIS)

    Theaudin, M.; Denier, C.; Adams, D.; Saliou, G.; Ducot, B.; Deiva, K.; Ducreux, D.

    2012-01-01

    The potential of diffusion tensor imaging (DTI) to detect spinal cord abnormalities in patients with multiple sclerosis has already been demonstrated. The objective of this study was to apply DTI techniques to multiple sclerosis patients with a recently diagnosed spinal cord lesion, in order to demonstrate a correlation between variations of DTI parameters and clinical outcome, and to try to identify DTI parameters predictive of outcome. A prospective single-centre study of patients with spinal cord relapse treated by intravenous steroid therapy was made. Patients were assessed clinically and by conventional MRI with DTI sequences at baseline and at 3 months. Sixteen patients were recruited. At 3 months, 12 patients were clinically improved. All but one patient had lower fractional anisotropy (FA) and apparent diffusion coefficient (ADC) values than normal subjects in either inflammatory lesions or normal-appearing spinal cord. Patients who improved at 3 months presented a significant reduction in the radial diffusivity (p = 0.05) in lesions during the follow-up period. They also had a significant reduction in the mean ADC (p = 0.002), axial diffusivity (p = 0.02), radial diffusivity (p = 0.02) and a significant increase in FA values (p = 0.02) in normal-appearing spinal cord. Patients in whom the American Spinal Injury Association sensory score improved at 3 months showed a significantly higher FA (p = 0.009) and lower radial diffusivity (p = 0.04) in inflammatory lesion at baseline compared to patients with no improvement. DTI MRI detects more extensive abnormalities than conventional T2 MRI. A less marked decrease in FA value and more marked decreased in radial diffusivity inside the inflammatory lesion were associated with better outcome. (orig.)

  19. Separate measurement of local diffusion coefficients in grain boundaries and in adjacent regions

    International Nuclear Information System (INIS)

    Klotsman, S.M.; Kajgorodov, V.N.

    1994-01-01

    A new measuring technique is presented that allows one separate determination of grain boundary width and local diffusion coefficients. With the use of the technique presented phenomenological description is accompished for time and temperature dependences of relative and absolute level populations in a zone of preferential intercrystalline diffusion. Local diffusion coefficients obtained for the upper temperature limit of applicability of the technique proposed are in a good agreement with values calculated form coordinate distribution of atoic probes. Local diffusion coefficients determined at lower temperatures essentially differ from those calculated assuming that suction coefficient is equal to a coefficient of volume diffusion. Experimental dta are given for diffusion parameters in Ag, Pd and W polycrystals. 16 refs., 3 figs., 2 tabs

  20. Measurements of brain microstructure and connectivity with diffusion MRI

    Directory of Open Access Journals (Sweden)

    Ching-Po Lin

    2011-12-01

    Full Text Available By probing direction-dependent diffusivity of water molecules, diffusion MRI has shown its capability to reflect the microstructural tissue status and to estimate the neural orientation and pathways in the living brain. This approach has supplied novel insights into in-vivo human brain connections. By detecting the connection patterns, anatomical architecture and structural integrity between cortical regions or subcortical nuclei in the living human brain can be easily identified. It thus opens a new window on brain connectivity studies and disease processes. During the past years, there is a growing interest in exploring the connectivity patterns of the human brain. Specifically, the utilities of noninvasive neuroimaging data and graph theoretical analysis have provided important insights into the anatomical connections and topological pattern of human brain structural networks in vivo. Here, we review the progress of this important technique and the recent methodological and application studies utilizing graph theoretical approaches on brain structural networks with structural MRI and diffusion MRI.

  1. The influence of the b-value combination on apparent diffusion coefficient based differentiation between malignant and benign tissue in cervical cancer

    NARCIS (Netherlands)

    Hoogendam, Jacob P.; Klerkx, Wenche M.; de Kort, Gerard A. P.; Bipat, Shandra; Zweemer, Ronald P.; Sie-Go, Daisy M. D. S.; Verheijen, René H. M.; Mali, Willem P. T. M.; Veldhuis, Wouter B.

    2010-01-01

    To analyze the influence of different b-value combinations on apparent diffusion coefficient (ADC)-based differentiation of known malignant and benign tissue in cervical cancer patients. A total of 35 patients with stage IB1, IB2, IIA cervical cancer underwent a 3.0T MRI scan prior to radical

  2. Turbulent eddy diffusion models in exposure assessment - Determination of the eddy diffusion coefficient.

    Science.gov (United States)

    Shao, Yuan; Ramachandran, Sandhya; Arnold, Susan; Ramachandran, Gurumurthy

    2017-03-01

    The use of the turbulent eddy diffusion model and its variants in exposure assessment is limited due to the lack of knowledge regarding the isotropic eddy diffusion coefficient, D T . But some studies have suggested a possible relationship between D T and the air changes per hour (ACH) through a room. The main goal of this study was to accurately estimate D T for a range of ACH values by minimizing the difference between the concentrations measured and predicted by eddy diffusion model. We constructed an experimental chamber with a spatial concentration gradient away from the contaminant source, and conducted 27 3-hr long experiments using toluene and acetone under different air flow conditions (0.43-2.89 ACHs). An eddy diffusion model accounting for chamber boundary, general ventilation, and advection was developed. A mathematical expression for the slope based on the geometrical parameters of the ventilation system was also derived. There is a strong linear relationship between D T and ACH, providing a surrogate parameter for estimating D T in real-life settings. For the first time, a mathematical expression for the relationship between D T and ACH has been derived that also corrects for non-ideal conditions, and the calculated value of the slope between these two parameters is very close to the experimentally determined value. The values of D T obtained from the experiments are generally consistent with values reported in the literature. They are also independent of averaging time of measurements, allowing for comparison of values obtained from different measurement settings. These findings make the use of turbulent eddy diffusion models for exposure assessment in workplace/indoor environments more practical.

  3. Apparent diffusion coefficient values and dynamic contrast enhancement patterns in differentiating seminomas from nonseminomatous testicular neoplasms

    Energy Technology Data Exchange (ETDEWEB)

    Tsili, Athina C., E-mail: a_tsili@yahoo.gr [Department of Radiology, Medical School, University of Ioannina, 45110 Ioannina (Greece); Sylakos, Anastasios, E-mail: anasylakos@yahoo.gr [Department of Urology, Medical School, University of Ioannina, 45110 Ioannina (Greece); Ntorkou, Alexandra, E-mail: alexdorkou@yahoo.com [Department of Radiology, Medical School, University of Ioannina, 45110 Ioannina (Greece); Stavrou, Sotirios, E-mail: s.sotiris@yahoo.gr [Department of Urology, Medical School, University of Ioannina, 45110 Ioannina (Greece); Astrakas, Loukas G., E-mail: astrakas@uoi.gr [Department of Medical Physics, Medical School, University of Ioannina, 45110 Ioannina (Greece); Sofikitis, Nikolaos, E-mail: akrosnin@hotmail.com [Department of Urology, Medical School, University of Ioannina, 45110 Ioannina (Greece); Argyropoulou, Maria I., E-mail: margyrop@cc.uoi.gr [Department of Radiology, Medical School, University of Ioannina, 45110 Ioannina (Greece)

    2015-07-15

    Highlights: • Functional MRI in the characterization of testicular germ cell tumors was assessed. • ADC values proved useful in the characterization of testicular germ cell tumors. • Testicular germ cell tumors had similar enhancement patterns of dynamic MRI. - Abstract: Introduction: The aim of this study is to investigate the role of apparent diffusion coefficient (ADC) values and dynamic contrast enhancement (DCE) patterns in differentiating seminomas from nonseminomatous germ cell tumors (NSGCTs). Materials and methods: The MRI examinations of the scrotum of 26 men with histologically proven testicular GCTs were reviewed. DWI was performed in all patients, using a single shot, multi-slice spin-echo planar diffusion pulse sequence and b-values of 0 and 900 s/mm{sup 2}. Subtraction DCE-MRI was performed in 20 cases using a 3D fast-field echo sequence after gadolinium administration. Time-signal intensity curves were created and semi-quantitative parameters (peak enhancement, time to peak, wash-in and wash-out rate) were calculated. The Student's t-test was used to compare the mean values of ADC, peak enhancement, time to peak, wash-in and wash-out rate between seminomas and NSGCTs. ROC analysis was also performed. Results: Histopathology disclosed the presence of 15 seminomas and 11 NSGCTs. The mean ± s.d. of ADC values (× 10{sup −3} mm{sup 2}/s) of seminomas (0.59 ± 0.009) were significantly lower than those of NSGCTs (0.90 ± 0.33) (P = 0.01). The optimal ADC cut-off value was 0.68 × 10{sup −3} mm{sup 2}/s. No differences between the two groups were observed for peak enhancement (P = 0.18), time to peak (P = 0.63) wash-in rate (P = 0.32) and wash-out rate (P = 0.18). Conclusions: ADC values may be used to preoperatively differentiate seminomas from NSGCTs.

  4. Diffusion-weighted MR and apparent diffusion coefficient in the evaluation of severe brain injury

    International Nuclear Information System (INIS)

    Nakahara, M.; Ericson, K.; Bellander, B.M.

    2001-01-01

    Purpose: To study apparent diffusion coefficient (ADC) maps in severely brain-injured patients. Material and Methods: Four deeply comatose patients with severe brain injury were investigated with single-shot, diffusion-weighted, spin-echo echo planar imaging. The tetrahedral diffusion gradient configuration and four iterations of a set of b-values (one time of 0 mm2/s, and four times of 1000 mm2/s) were used to create isotropic ADC maps with high signal-to-noise ratio. ADC values of gray and white matter were compared among patients and 4 reference subjects. Results: one patient was diagnosed as clinically brain dead after the MR examination. The patient's ADC values of gray and white matter were significantly lower than those of 3 other brain-injured patients. In addition the ADC value of white matter was significantly lower than that of gray matter. Conclusion: The patient with fatal outcome shortly after MR examination differed significantly from other patients with severe brain injury but non-fatal outcome, with regard to ADC values in gray and white matter. This might indicate a prognostic value of ADC maps in the evaluation of traumatic brain injury

  5. Report of diffusion-weighted MRI in two cases with different cerebral hydatid disease

    Energy Technology Data Exchange (ETDEWEB)

    Kitis, O.; Calli, C.; Yunten, N. [Ege Univ., Izmir (Turkey). Dept. of Radiology

    2004-02-01

    To present MRI findings in two cases of cerebral hydatid disease with an emphasis on diffusion-weighted imaging (DWI) findings of Echinococcus granulosus (EG) versus Echinococcus alveolaris (EA). EG lesions were isointense with cerebrospinal fluid in all sequences including DWI. On DWI, EA lesions remained hypointense on b = 1000 s/mm2 diffusion-weighted images. Apparent diffusion coefficient (ADC) values of EG and EA lesions were completely different from each other, 2.88 {+-} 0.24 x 10{sup -3} s/mm{sup 2} and 1.33 {+-} 0.15 x 10{sup -3} s/mm{sup 2}, respectively. The ADC values could not be used to discriminate from other differential diagnoses.

  6. Report of diffusion-weighted MRI in two cases with different cerebral hydatid disease

    International Nuclear Information System (INIS)

    Kitis, O.; Calli, C.; Yunten, N.

    2004-01-01

    To present MRI findings in two cases of cerebral hydatid disease with an emphasis on diffusion-weighted imaging (DWI) findings of Echinococcus granulosus (EG) versus Echinococcus alveolaris (EA). EG lesions were isointense with cerebrospinal fluid in all sequences including DWI. On DWI, EA lesions remained hypointense on b = 1000 s/mm2 diffusion-weighted images. Apparent diffusion coefficient (ADC) values of EG and EA lesions were completely different from each other, 2.88 ± 0.24 x 10 -3 s/mm 2 and 1.33 ± 0.15 x 10 -3 s/mm 2 , respectively. The ADC values could not be used to discriminate from other differential diagnoses

  7. Evaluation of malignant and benign renal lesions using diffusion-weighted MRI with multiple b values

    International Nuclear Information System (INIS)

    Erbay, Gurcan; Koc, Zafer; Karadeli, Elif; Kuzgunbay, Baris; Goren, M. Resit; Bal, Nebil

    2012-01-01

    Background: Limited data are available regarding the use of diffusion-weighted (DW) magnetic resonance imaging (MRI) with multiple b values for characterization of renal lesions. Purpose: To demonstrate and compare the diagnostic performance of DW-MRI with multiple b values for renal lesion characterization. Material and Methods: Sixty-three lesions (36 malignant, 27 benign) in 60 consecutive patients (48 men, 12 women; age 60 ± 12.5 years) with solid/cystic renal lesion diagnosed after MRI were included prospectively. Single-shot echo-planar DW abdominal MRI (1.5T) was obtained using seven b values with eight apparent diffusion coefficient (ADC) maps. Contrast-to-noise ratios (CNRs), signal intensities, lesion ADCs, and lesion/normal parenchyma ADC ratios were analyzed. Receiver-operating characteristic analysis was performed. Results: The mean signal intensities of malignant lesions (at b0, 50, and 200 s/mm 2 ) were significantly lower than those of benign lesions (P 2 . ADC with all b values could better distinguish between benign and malignant lesions. A 1.35 x 10 -3 mm 2 /s threshold ADC value permitted this distinction with 85.2% sensitivity and 65.6% specificity. The lesion/normal parenchyma ADC ratio was more effective than the lesion ADC. Conclusion: In addition to the ADC value, the signal intensity curve on DW images using multiple b values could be helpful for differentiation of malignant and benign renal lesions

  8. Separation of type and grade in cervical tumours using non-mono-exponential models of diffusion-weighted MRI

    International Nuclear Information System (INIS)

    Winfield, Jessica M.; Collins, David J.; Morgan, Veronica A.; DeSouza, Nandita M.; Orton, Matthew R.; Ind, Thomas E.J.; Attygalle, Ayoma; Hazell, Steve

    2017-01-01

    Assessment of empirical diffusion-weighted MRI (DW-MRI) models in cervical tumours to investigate whether fitted parameters distinguish between types and grades of tumours. Forty-two patients (24 squamous cell carcinomas, 14 well/moderately differentiated, 10 poorly differentiated; 15 adenocarcinomas, 13 well/moderately differentiated, two poorly differentiated; three rare types) were imaged at 3 T using nine b-values (0 to 800 s mm -2 ). Mono-exponential, stretched exponential, kurtosis, statistical, and bi-exponential models were fitted. Model preference was assessed using Bayesian Information Criterion analysis. Differences in fitted parameters between tumour types/grades and correlation between fitted parameters were assessed using two-way analysis of variance and Pearson's linear correlation coefficient, respectively. Non-mono-exponential models were preferred by 83 % of tumours with bi-exponential and stretched exponential models preferred by the largest numbers of tumours. Apparent diffusion coefficient (ADC) and diffusion coefficients from non-mono-exponential models were significantly lower in poorly differentiated tumours than well/moderately differentiated tumours. α (stretched exponential), K (kurtosis), f and D* (bi-exponential) were significantly different between tumour types. Strong correlation was observed between ADC and diffusion coefficients from other models. Non-mono-exponential models were preferred to the mono-exponential model in DW-MRI data from cervical tumours. Parameters of non-mono-exponential models showed significant differences between types and grades of tumours. (orig.)

  9. Separation of type and grade in cervical tumours using non-mono-exponential models of diffusion-weighted MRI

    Energy Technology Data Exchange (ETDEWEB)

    Winfield, Jessica M.; Collins, David J.; Morgan, Veronica A.; DeSouza, Nandita M. [The Royal Marsden NHS Foundation Trust, MRI Unit, Sutton, Surrey (United Kingdom); The Institute of Cancer Research, Cancer Research UK Cancer Imaging Centre, Division of Radiotherapy and Imaging, London (United Kingdom); Orton, Matthew R. [The Institute of Cancer Research, Cancer Research UK Cancer Imaging Centre, Division of Radiotherapy and Imaging, London (United Kingdom); Ind, Thomas E.J. [The Royal Marsden NHS Foundation Trust, Gynaecology Unit, London (United Kingdom); Attygalle, Ayoma; Hazell, Steve [The Royal Marsden NHS Foundation Trust, Department of Histopathology, London (United Kingdom)

    2017-02-15

    Assessment of empirical diffusion-weighted MRI (DW-MRI) models in cervical tumours to investigate whether fitted parameters distinguish between types and grades of tumours. Forty-two patients (24 squamous cell carcinomas, 14 well/moderately differentiated, 10 poorly differentiated; 15 adenocarcinomas, 13 well/moderately differentiated, two poorly differentiated; three rare types) were imaged at 3 T using nine b-values (0 to 800 s mm{sup -2}). Mono-exponential, stretched exponential, kurtosis, statistical, and bi-exponential models were fitted. Model preference was assessed using Bayesian Information Criterion analysis. Differences in fitted parameters between tumour types/grades and correlation between fitted parameters were assessed using two-way analysis of variance and Pearson's linear correlation coefficient, respectively. Non-mono-exponential models were preferred by 83 % of tumours with bi-exponential and stretched exponential models preferred by the largest numbers of tumours. Apparent diffusion coefficient (ADC) and diffusion coefficients from non-mono-exponential models were significantly lower in poorly differentiated tumours than well/moderately differentiated tumours. α (stretched exponential), K (kurtosis), f and D* (bi-exponential) were significantly different between tumour types. Strong correlation was observed between ADC and diffusion coefficients from other models. Non-mono-exponential models were preferred to the mono-exponential model in DW-MRI data from cervical tumours. Parameters of non-mono-exponential models showed significant differences between types and grades of tumours. (orig.)

  10. Apparent diffusion coefficient (ADC) does not correlate with different serological parameters in myositis and myopathy.

    Science.gov (United States)

    Meyer, Hans-Jonas; Ziemann, Oliver; Kornhuber, Malte; Emmer, Alexander; Quäschling, Ulf; Schob, Stefan; Surov, Alexey

    2018-06-01

    Background Magnetic resonance imaging (MRI) is widely used in several muscle disorders. Diffusion-weighted imaging (DWI) is an imaging modality, which can reflect microstructural tissue composition. The apparent diffusion coefficient (ADC) is used to quantify the random motion of water molecules in tissue. Purpose To investigate ADC values in patients with myositis and non-inflammatory myopathy and to analyze possible associations between ADC and laboratory parameters in these patients. Material and Methods Overall, 17 patients with several myositis entities, eight patients with non-inflammatory myopathies, and nine patients without muscle disorder as a control group were included in the study (mean age = 55.3 ± 14.3 years). The diagnosis was confirmed by histopathology in every case. DWI was obtained in a 1.5-T scanner using two b-values: 0 and 1000 s/mm 2 . In all patients, the blood sample was acquired within three days to the MRI. The following serological parameters were estimated: C-reactive protein, lactate dehydrogenase, alanine aminotransferase, aspartate aminotransferase, creatine kinase, and myoglobine. Results The estimated mean ADC value for the myositis group was 1.89 ± 0.37 × 10 -3  mm 2 /s and for the non-inflammatory myopathy group was 1.79 ± 0.33 × 10 -3  mm 2 /s, respectively. The mean ADC values (1.15 ± 0.37 × 10 -3  mm 2 /s) were significantly higher to unaffected muscles (vs. myositis P = 0.0002 and vs. myopathy P = 0.0021). There were no significant correlations between serological parameters and ADC values. Conclusion Affected muscles showed statistically significantly higher ADC values than normal muscles. No linear correlations between ADC and serological parameters were identified.

  11. Diffusion-Coefficients of Sulfate and Methane in Marine-Sediments - Influence of Porosity

    DEFF Research Database (Denmark)

    IVERSEN, N.; JØRGENSEN, BB

    1993-01-01

    diffusion coefficients can be related to the diffusion coefficient in free solution by D(s) = D(o)/theta2, where theta is the tortuosity of the sediment. The sediment tortuosity calculated from this equation showed a linear relationship with sediment porosity (phi) over the porosity range of 0.4-0.9. From...

  12. Study on the chloride diffusion coefficient in concrete obtained in electrically accelerated tests

    NARCIS (Netherlands)

    Spiesz, P.R.; Brouwers, H.J.H.; Gulikers, J.J.W.; Polder, R.; Andrade, C.

    2015-01-01

    This study presents an analysis of the chloride diffusion coefficient (DRCM), obtained in electrically accelerated chloride migration tests. As demonstrated here, the obtained chloride diffusion coefficient does not represent the apparent one, as it is independent of chloride binding. This is

  13. Correlation factor, velocity autocorrelation function and frequency-dependent tracer diffusion coefficient

    NARCIS (Netherlands)

    Beijeren, H. van; Kehr, K.W.

    1986-01-01

    The correlation factor, defined as the ratio between the tracer diffusion coefficient in lattice gases and the diffusion coefficient for a corresponding uncorrelated random walk, is known to assume a very simple form under certain conditions. A simple derivation of this is given with the aid of

  14. Apparent diffusion coefficient value as a biomarker reflecting morphological and biological features of prostate cancer.

    Science.gov (United States)

    Bae, Hyeyeol; Yoshida, Soichiro; Matsuoka, Yoh; Nakajima, Hiroshi; Ito, Eisaku; Tanaka, Hiroshi; Oya, Miyako; Nakayama, Takayuki; Takeshita, Hideki; Kijima, Toshiki; Ishioka, Junichiro; Numao, Noboru; Koga, Fumitaka; Saito, Kazutaka; Akashi, Takumi; Fujii, Yasuhisa; Kihara, Kazunori

    2014-03-01

    To assess whether there is an association between the apparent diffusion coefficient (ADC) value and the pathological characteristics of prostate cancer. The study cohort consisted of 29 consecutive patients with prostate cancer treated with radical prostatectomy. All patients underwent diffusion-weighted MRI before the prostate biopsy. In 42 tumor foci, the associations of the ADC values with the clinicopathological characteristics and Ki-67 labeling index (LI) were analyzed. High-grade cancers (Gleason score [GS] ≥ 4 + 3), larger cancers (maximum diameter (MD) ≥ 16 mm), and highly proliferating cancers (Ki-67 LI ≥ 4.43 %) had significantly lower ADC values, respectively (P value according to age, prostate-specific antigen, presence of extra-prostatic extension, and intra-tumoral stroma proportion. Multivariate analysis showed that GS, Ki-67 LI, and MD had independent and significant correlations with ADC value (P value to predict high-grade cancer foci are 81.8 and 93.5 %, respectively. A low ADC value reflects the morphological and biological features of prostate cancer. Analyzing the ADC value may make it possible to more precisely predict the cancer aggressiveness of each focus before treatment.

  15. Temperature dependence of Self-diffusion coefficient (SDC) of liquid ...

    African Journals Online (AJOL)

    PROF HORSFALL

    2018-04-09

    Apr 9, 2018 ... inverse square relationship between the natural logarithm of self-diffusion ... using the Equilibrium Molecular Dynamics (MD) and ..... Density, and Viscosity of Liquid Aluminum and. Iron. J. Phys. Chem. Ref. Data 35 ... Atomic Diffusion in Condensed Matter. Nature. 381: 137. Einstein, A (1905). Annalen der ...

  16. Effective diffusion coefficients of /sup 3/H/sub 2/O in several porous materials

    Energy Technology Data Exchange (ETDEWEB)

    Terashima, Y [Kyoto Univ. (Japan). Faculty of Engineering; Kumaki, T

    1976-12-01

    Diffusion coefficients of radionuclides in some porous structural materials and porous components of earth stratum are important as the basis for the safety evaluation of the storage and disposal of radioactive wastes. In our previous works, the method of analysis and experiment using a permeative type diffusion cell for measurement of effective diffusion coefficient was established, and experimental results were reported. In this paper, effective diffusion coefficients of /sup 3/H/sub 2/O in mortar, concrete, brick, clay layer, and sand layer were measured, and characteristics of these pore structure were discussed on the basis of tourtusity factor.

  17. Effective diffusion coefficients of 3H2O in several porous materials

    International Nuclear Information System (INIS)

    Terashima, Yutaka; Kumaki, Toru.

    1976-01-01

    Diffusion coefficients of radionuclides in some porous structural materials and porous components of earth stratum are important as the basis for the safety evaluation of the storage and disposal of radioactive wastes. In our previous works, the method of analysis and experiment using a permeative type diffusion cell for measurement of effective diffusion coefficient was established, and experimental results were reported. In this paper, effective diffusion coefficients of 3 H 2 O in mortar, concrete, brick, clay layer, and sand layer were measured, and characteristics of these pore structure were discussed on the basis of tourtusity factor. (auth.)

  18. Temperature effects on diffusion coefficient for 6-gingerol and 6-shogaol in subcritical water extraction

    Science.gov (United States)

    Ilia Anisa, Nor; Azian, Noor; Sharizan, Mohd; Iwai, Yoshio

    2014-04-01

    6-gingerol and 6-shogaol are the main constituents as anti-inflammatory or bioactive compounds from zingiber officinale Roscoe. These bioactive compounds have been proven for inflammatory disease, antioxidatives and anticancer. The effect of temperature on diffusion coefficient for 6-gingerol and 6-shogaol were studied in subcritical water extraction. The diffusion coefficient was determined by Fick's second law. By neglecting external mass transfer and solid particle in spherical form, a linear portion of Ln (1-(Ct/Co)) versus time was plotted in determining the diffusion coefficient. 6-gingerol obtained the higher yield at 130°C with diffusion coefficient of 8.582x10-11 m2/s whilst for 6-shogaol, the higher yield and diffusion coefficient at 170°C and 19.417 × 10-11 m2/s.

  19. Temperature effects on diffusion coefficient for 6-gingerol and 6-shogaol in subcritical water extraction

    International Nuclear Information System (INIS)

    Anisa, Nor Ilia; Azian, Noor; Sharizan, Mohd; Iwai, Yoshio

    2014-01-01

    6-gingerol and 6-shogaol are the main constituents as anti-inflammatory or bioactive compounds from zingiber officinale Roscoe. These bioactive compounds have been proven for inflammatory disease, antioxidatives and anticancer. The effect of temperature on diffusion coefficient for 6-gingerol and 6-shogaol were studied in subcritical water extraction. The diffusion coefficient was determined by Fick's second law. By neglecting external mass transfer and solid particle in spherical form, a linear portion of Ln (1-(Ct/Co)) versus time was plotted in determining the diffusion coefficient. 6-gingerol obtained the higher yield at 130°C with diffusion coefficient of 8.582x10 −11 m 2 /s whilst for 6-shogaol, the higher yield and diffusion coefficient at 170°C and 19.417 × 10 −11 m 2 /s.

  20. Determination of trapping parameters and the chemical diffusion coefficient from hydrogen permeation experiments

    International Nuclear Information System (INIS)

    Svoboda, J.; Mori, G.; Prethaler, A.; Fischer, F.D.

    2014-01-01

    Highlights: • A modeling study for diffusion of hydrogen with traps is presented. • Introduction of a new chemical diffusion coefficient. • Density of traps and average depth of traps can be determined. • Lattice diffusion and sub-surface concentration of atomic hydrogen can be determined. - Abstract: An improved diffusion theory accounting for trapping effects is applied to evaluation of hydrogen permeation experiments performed for pure iron and pearlitic and martensitic steels. The trapping parameters as molar volume and depth of traps are determined by fitting experiments by simulations based on the theory. The concentration-dependent chemical diffusion coefficient of hydrogen is extracted indicating that the trapping effect on diffusion in pure iron and pearlitic steel is negligible. However, it is significant for martensitic steel, for which the chemical diffusion coefficient cannot be considered as concentration-independent as it is established in current standards

  1. Endometrial cancer: correlation of apparent diffusion coefficient (ADC) with tumor cellularity and tumor grade.

    Science.gov (United States)

    Kishimoto, Keiko; Tajima, Shinya; Maeda, Ichiro; Takagi, Masayuki; Ueno, Takahiko; Suzuki, Nao; Nakajima, Yasuo

    2016-08-01

    Diffusion-weighted imaging (DWI) and the apparent diffusion coefficient (ADC) are widely used for detecting uterine endometrial cancer. The relationships between ADC values and pathological features of endometrial cancer have not yet been established. To investigate whether ADC values of endometrial cancer vary according to histologic tumor cellularity and tumor grade. We retrospectively reviewed 30 pathologically confirmed endometrial cancers. All patients underwent conventional non-enhanced magnetic resonance imaging (MRI) and DWI procedures, and ADC values were calculated. Tumor cellularity was evaluated by counting cancer cells in three high-power ( × 400) fields. The correlation between ADC values and tumor cellularity was assessed using Pearson's correlation coefficient test for statistical analysis. The mean ± standard deviation (SD) ADC value ( ×10(-3) mm(2)/s) of endometrial cancer was 0.85 ± 0.22 (range, 0.55-1.71). The mean ± SD tumor cellularity was 528.36 ± 16.89 (range, 298.0-763.6). ADC values were significantly inversely correlated with tumor cellularity. No significant relationship was observed between ADC values and tumor grade (mean ADC values: G1, 0.88 ± 0.265 × 10(-3) mm(2)/s; G2, 0.80 ± 0.178 × 10(-3) mm(2)/s; G3, 0.81 ± 0.117 × 10(-3) mm(2)/s). There is a significant inverse relationship between ADC values and tumor cellularity in endometrial cancer. No significant differences in average ADC value were observed between G1, G2, and G3 tumors. However, the lower the tumor grade, the wider the SD. © The Foundation Acta Radiologica 2015.

  2. Atypical abdominal paediatric lymphangiomatosis: diagnosis aided by diffusion-weighted MRI

    International Nuclear Information System (INIS)

    Humphries, Paul D.; Olsen, Oeystein E.; Wynne, Catherine S.; Sebire, Neil J.

    2006-01-01

    We report a 4-year-old child with a mesenteric mass, which on ultrasound, CT and conventional MRI appeared solid, raising lymphoma as a possible diagnosis. Diffusion weighted MRI (DW-MRI), however, suggested a low-cellularity lesion, making lymphoma less likely. Biopsy confirmed lymphangioma. DW-MRI may be a useful adjunct to conventional imaging, even in the abdomen. (orig.)

  3. Apparent diffusion coefficient value of gastric cancer by diffusion-weighted imaging: Correlations with the histological differentiation and Lauren classification

    International Nuclear Information System (INIS)

    Liu, Song; Guan, Wenxian; Wang, Hao; Pan, Liang; Zhou, Zhuping; Yu, Haiping; Liu, Tian; Yang, Xiaofeng; He, Jian; Zhou, Zhengyang

    2014-01-01

    Highlights: • Gastric cancers’ ADC values were significantly lower than normal gastric wall. • Gastric adenocarcinomas with different differentiation had different ADC values. • Gastric adenocarcinomas’ ADC values correlated with histologic differentiations. • Gastric cancers’ ADC values correlated with Lauren classifications. • Mean ADC value was better than min ADC value in characterizing gastric cancers. - Abstract: Objective: The purpose of this study was to evaluate the correlations between histological differentiation and Lauren classification of gastric cancer and the apparent diffusion coefficient (ADC) value of diffusion weighted imaging (DWI). Materials and methods: Sixty-nine patients with gastric cancer lesions underwent preoperative magnetic resonance imaging (MRI) (3.0T) and surgical resection. DWI was obtained with a single-shot, echo-planar imaging sequence in the axial plane (b values: 0 and 1000 s/mm 2 ). Mean and minimum ADC values were obtained for each gastric cancer and normal gastric walls by two radiologists, who were blinded to the histological findings. Histological type, degree of differentiation and Lauren classification of each resected specimen were determined by one pathologist. Mean and minimum ADC values of gastric cancers with different histological types, degrees of differentiation and Lauren classifications were compared. Correlations between ADC values and histological differentiation and Lauren classification were analyzed. Results: The mean and minimum ADC values of gastric cancers, as a whole and separately, were significantly lower than those of normal gastric walls (all p values <0.001). There were significant differences in the mean and minimum ADC values among gastric cancers with different histological types, degrees of differentiation and Lauren classifications (p < 0.05). Mean and minimum ADC values correlated significantly (all p < 0.001) with histological differentiation (r = 0.564, 0.578) and Lauren

  4. Joint brain connectivity estimation from diffusion and functional MRI data

    Science.gov (United States)

    Chu, Shu-Hsien; Lenglet, Christophe; Parhi, Keshab K.

    2015-03-01

    Estimating brain wiring patterns is critical to better understand the brain organization and function. Anatomical brain connectivity models axonal pathways, while the functional brain connectivity characterizes the statistical dependencies and correlation between the activities of various brain regions. The synchronization of brain activity can be inferred through the variation of blood-oxygen-level dependent (BOLD) signal from functional MRI (fMRI) and the neural connections can be estimated using tractography from diffusion MRI (dMRI). Functional connections between brain regions are supported by anatomical connections, and the synchronization of brain activities arises through sharing of information in the form of electro-chemical signals on axon pathways. Jointly modeling fMRI and dMRI data may improve the accuracy in constructing anatomical connectivity as well as functional connectivity. Such an approach may lead to novel multimodal biomarkers potentially able to better capture functional and anatomical connectivity variations. We present a novel brain network model which jointly models the dMRI and fMRI data to improve the anatomical connectivity estimation and extract the anatomical subnetworks associated with specific functional modes by constraining the anatomical connections as structural supports to the functional connections. The key idea is similar to a multi-commodity flow optimization problem that minimizes the cost or maximizes the efficiency for flow configuration and simultaneously fulfills the supply-demand constraint for each commodity. In the proposed network, the nodes represent the grey matter (GM) regions providing brain functionality, and the links represent white matter (WM) fiber bundles connecting those regions and delivering information. The commodities can be thought of as the information corresponding to brain activity patterns as obtained for instance by independent component analysis (ICA) of fMRI data. The concept of information

  5. Apparent diffusion coefficient histogram analysis of neonatal hypoxic-ischemic encephalopathy

    Energy Technology Data Exchange (ETDEWEB)

    Cauley, Keith A. [University of Massachusetts Medical School, Department of Radiology, Worcester, MA (United States); New York Presbyterian Hospital, Columbia University Medical Center, Department of Radiology, New York, NY (United States); Filippi, Christopher G. [New York Presbyterian Hospital, Columbia University Medical Center, Department of Radiology, New York, NY (United States)

    2014-06-15

    Diffusion-weighted imaging is a valuable tool in the assessment of the neonatal brain, and changes in diffusion are seen in normal development as well as in pathological states such as hypoxic-ischemic encephalopathy (HIE). Various methods of quantitative assessment of diffusion values have been reported. Global ischemic injury occurring during the time of rapid developmental changes in brain myelination can complicate the imaging diagnosis of neonatal HIE. To compare a quantitative method of histographic analysis of brain apparent coefficient (ADC) maps to the qualitative interpretation of routine brain MR imaging studies. We correlate changes in diffusion values with gestational age in radiographically normal neonates, and we investigate the sensitivity of the method as a quantitative measure of hypoxic-ischemic encephalopathy. We reviewed all brain MRI studies from the neonatal intensive care unit (NICU) at our university medical center over a 4-year period to identify cases that were radiographically normal (23 cases) and those with diffuse, global hypoxic-ischemic encephalopathy (12 cases). We histographically displayed ADC values of a single brain slice at the level of the basal ganglia and correlated peak (s-sD{sub av}) and lowest histogram values (s-sD{sub lowest}) with gestational age. Normative s-sD{sub av} values correlated significantly with gestational age and declined linearly through the neonatal period (r {sup 2} = 0.477, P < 0.01). Six of 12 cases of known HIE demonstrated significantly lower s-sD{sub av} and s-sD{sub lowest} ADC values than were reflected in the normative distribution; several cases of HIE fell within a 95% confidence interval for normative studies, and one case demonstrated higher-than-normal s-sD{sub av}. Single-slice histographic display of ADC values is a rapid and clinically feasible method of quantitative analysis of diffusion. In this study normative values derived from consecutive neonates without radiographic evidence of

  6. Determination of diffusion coefficients and diffusion characteristics for chlorferon and diethylthiophosphate in Ca-alginate gel beads.

    Science.gov (United States)

    Ha, Jiyeon; Engler, Cady R; Lee, Seung Jae

    2008-07-01

    Diffusion characteristics of chlorferon and diethylthiophosphate (DETP) in Ca-alginate gel beads were studied to assist in designing and operating bioreactor systems. Diffusion coefficients for chlorferon and DETP in Ca-alginate gel beads determined at conditions suitable for biodegradation studies were 2.70 x 10(-11) m(2)/s and 4.28 x 10(-11) m(2)/s, respectively. Diffusivities of chlorferon and DETP were influenced by several factors, including viscosity of the bulk solution, agitation speed, and the concentrations of diffusing substrate and immobilized cells. Diffusion coefficients increased with increasing agitation speed, probably due to poor mixing at low speed and some attrition of beads at high speeds. Diffusion coefficients also increased with decreasing substrate concentration. Increased cell concentration in the gel beads caused lower diffusivity. Theoretical models to predict diffusivities as a function of cell weight fraction overestimated the effective diffusivities for both chlorferon and DETP, but linear relations between effective diffusivity and cell weight fraction were derived from experimental data. Calcium-alginate gel beads with radii of 1.65-1.70 mm used in this study were not subject to diffusional limitations: external mass transfer resistances were negligible based on Biot number calculations and effectiveness factors indicated that internal mass transfer resistance was negligible. Therefore, the degradation rates of chlorferon and DETP inside Ca-alginate gel beads were reaction-limited. (c) 2007 Wiley Periodicals, Inc.

  7. Ischemic lesion volume determination on diffusion weighted images vs. apparent diffusion coefficient maps.

    Science.gov (United States)

    Bråtane, Bernt Tore; Bastan, Birgul; Fisher, Marc; Bouley, James; Henninger, Nils

    2009-07-07

    Though diffusion weighted imaging (DWI) is frequently used for identifying the ischemic lesion in focal cerebral ischemia, the understanding of spatiotemporal evolution patterns observed with different analysis methods remains imprecise. DWI and calculated apparent diffusion coefficient (ADC) maps were serially obtained in rat stroke models (MCAO): permanent, 90 min, and 180 min temporary MCAO. Lesion volumes were analyzed in a blinded and randomized manner by 2 investigators using (i) a previously validated ADC threshold, (ii) visual determination of hypointense regions on ADC maps, and (iii) visual determination of hyperintense regions on DWI. Lesion volumes were correlated with 24 hour 2,3,5-triphenyltetrazoliumchloride (TTC)-derived infarct volumes. TTC-derived infarct volumes were not significantly different from the ADC and DWI-derived lesion volumes at the last imaging time points except for significantly smaller DWI lesions in the pMCAO model (p=0.02). Volumetric calculation based on TTC-derived infarct also correlated significantly stronger to volumetric calculation based on last imaging time point derived lesions on ADC maps than DWI (pdetermined lesion volumes on ADC maps and DWI by both investigators correlated significantly with threshold-derived lesion volumes on ADC maps with the former method demonstrating a stronger correlation. There was also a better interrater agreement for ADC map analysis than for DWI analysis. Ischemic lesion determination by ADC was more accurate in final infarct prediction, rater independent, and provided exclusive information on ischemic lesion reversibility.

  8. The mutual diffusion coefficient for (meth)acrylate monomers as determined with a nuclear microprobe

    International Nuclear Information System (INIS)

    Leewis, Christian M.; Mutsaers, Peter H.A.; Jong, Arthur M. de; Ijzendoorn, Leo J. van; Voigt, Martien J.A. de; Ren, Min Q.; Watt, Frank; Broer, Dirk J.

    2004-01-01

    The value of the mutual diffusion coefficient D V of two acrylic monomers is determined with nuclear microprobe measurements on a set of polymer films. These films have been prepared by allowing the monomers to diffuse into each other for a certain time and subsequently applying fast ultraviolet photo-polymerization, which freezes the concentration profile. The monomer diffusion profiles are studied with a scanning 2.1 MeV proton microprobe. Each monomer contains a marker element, e.g., Cl and Si, which are easily detected with proton induced x-ray emission. From the diffusion profiles, it is possible to determine the mutual diffusion coefficient. The mutual diffusion coefficient is dependent of concentration, which is concluded from the asymmetry in the Cl- and Si-profiles. A linear dependence of the mutual diffusion coefficient on the composition is used as a first order approximation. The best fits are obtained for a value of b=(0.38±0.15), which is the ratio of the diffusion coefficient of 1,3-bis(3-methacryloxypropyl)-1, 1,3,3-tetramethyldisiloxane in pure 2-chloroethyl acrylate and the diffusion coefficient of 2-chloroethyl acrylate in pure 1,3-bis(3-methacryloxypropyl)-1,1,3,3-tetramethyldisiloxane. Under the assumption of a linear dependence of the mutual diffusion coefficient D V on monomer composition, it follows that D V =(2.9±0.6)·10 -10 m 2 /s at a 1:1 monomer ratio. With Flory-Huggins expressions for the monomer chemical potentials, one can derive approximate values for the individual monomer diffusion coefficients

  9. Sensitivity analysis of an experimental methodology to determine radionuclide diffusion coefficients in granite

    International Nuclear Information System (INIS)

    Alonso, U.; Missana, T.; Garcia-Gutierrez, M.; Patelli, A.; Rigato, V.

    2005-01-01

    Full text of publication follows: The long-term quantitative analysis of the migration behaviour of the relevant radionuclides (RN) within the geological barrier of a radioactive waste repository requires, amongst other data, the introduction of reliable transport parameters, as diffusion coefficients. Since the determination of diffusion coefficients within crystalline rocks is complex and requires long experimental times even for non-sorbing radionuclides, the data available in the literature are very scarce. The nuclear ion beam technique RBS (Rutherford Backscattering Spectrometry) that is successfully used to determine diffusion profiles in thin film science is here examined as possible suitable technique to determine the diffusion coefficients of different RN within granite. As first step, the technique sensitivity and limitations to analyse diffusion coefficients in granite samples is evaluated, considering that the technique is especially sensitive to heavy elements. The required experimental conditions in terms of experimental times, concentration and methodology of analysis are discussed. The diffusants were selected accounting the RBS sensitivity but also trying to cover different behaviours of critical RN and a wide range of possible oxidation states. In particular, Cs(I) was chosen as representative fission product, while as relevant actinides or homologues, the diffusion of Th(IV), U(IV) and Eu (III) was studied. The diffusion of these above-mentioned cations is compared to the diffusion of Re, and I as representative of anionic species. The methodology allowed evaluating diffusion coefficients in the granite samples and, for most of the elements, the values obtained are in agreement with the values found in the literature. The diffusion coefficients calculated ranged from 10 -13 to 10 -16 m 2 /s. It is remarkable that the RBS technique is especially promising to determine diffusion coefficients of high-sorbing RN and it is applicable to a wide range

  10. Diffusion-weighted MRI of kidneys in healthy volunteers and living kidney donors

    International Nuclear Information System (INIS)

    Sulkowska, K.; Palczewski, P.; Duda-Zysk, A.; Szeszkowski, W.; Wojcik, D.; Kownacka-Piotrowska, D.; Gołebiowski, M.

    2015-01-01

    Aim: To establish the normal apparent diffusion coefficient (ADC) values in healthy kidneys, comparing them with the literature, and assessing the correlation between ADC values, creatinine blood level, and glomerular filtration rate (GFR). Materials and methods: Twenty-four healthy volunteers and 26 living kidney donors were examined on a 1.5 T magnetic resonance imaging (MRI) unit. Two diffusion-weighted imaging (DWI) sequences were included in the study protocol (protocol 1 with 16 b-values, protocol 2 with 10 b-values) before the examination blood and urine samples were collected. The GFR was calculated using Cockcroft & Gault and MDRD (Modification of Diet In Renal Disease) formulas and the ADC values were measured separately for the cortex and medulla of each kidney by two independent observers. All statistical analyses were performed using the STATISTICA (version 10.0) software package. Data were analysed using an unpaired t-test; p<0.05 indicated a statistically significant difference. Results: The average ADC value for protocol 1 for the cortex was 2.26×10 −3  mm 2 /s, for the medulla 2.21×10 −3  mm 2 /s. In protocol 2, the respective values were 2.13×10 −3  mm 2 /s and 2.06×10 −3  mm 2 /s. Neither statistically significant interobserver differences nor correlation between ADC values, GFR, and creatinine serum level were observed. Conclusion: The reference ADC values were established. The measurements show high interobserver consistency. The differences in ADC values reported in the literature suggest dependence on the equipment and methodology and point to the necessity of obtaining ADC norms for each MRI unit. -- Highlights: •Magnetic resonance diffusion-weighted imaging of kidneys. •Apparent diffusion coefficient in healthy individuals. •Monoexponential model of diffusion

  11. Effective diffusion coefficients of DNAPL waste components in saturated low permeability soil materials

    Science.gov (United States)

    Ayral-Cinar, Derya; Demond, Avery H.

    2017-12-01

    Diffusion is regarded as the dominant transport mechanism into and out of low permeable subsurface lenses and layers in the subsurface. But, some reports of mass storage in such zones are higher than what might be attributable to diffusion, based on estimated diffusion coefficients. Despite the importance of diffusion to efforts to estimate the quantity of residual contamination in the subsurface, relatively few studies present measured diffusion coefficients of organic solutes in saturated low permeability soils. This study reports the diffusion coefficients of a trichloroethylene (TCE), and an anionic surfactant, Aerosol OT (AOT), in water-saturated silt and a silt-montmorillonite (25:75) mixture, obtained using steady-state experiments. The relative diffusivity ranged from 0.11 to 0.17 for all three compounds for the silt and the silt-clay mixture that was allowed to expand. In the case in which the swelling was constrained, the relative diffusivity was about 0.07. In addition, the relative diffusivity of 13C-labeled TCE through a water saturated silt-clay mixture that had contacted a field dense non-aqueous phase liquid (DNAPL) for 18 months was measured and equaled 0.001. These experimental results were compared with the estimates generated using common correlations, and it was found that, in all cases, the measured diffusion coefficients were significantly lower than the estimated. Thus, the discrepancy between mass accumulations observed in the field and the mass storage that can attributable to diffusion may be greater than previously believed.

  12. Diffusion

    International Nuclear Information System (INIS)

    Kubaschewski, O.

    1983-01-01

    The diffusion rate values of titanium, its compounds and alloys are summarized and tabulated. The individual chemical diffusion coefficients and self-diffusion coefficients of certain isotopes are given. Experimental methods are listed which were used for the determination of diffusion coefficients. Some values have been taken over from other studies. Also given are graphs showing the temperature dependences of diffusion and changes in the diffusion coefficient with concentration changes

  13. Evaluation Technique of Chloride Penetration Using Apparent Diffusion Coefficient and Neural Network Algorithm

    Directory of Open Access Journals (Sweden)

    Yun-Yong Kim

    2014-01-01

    Full Text Available Diffusion coefficient from chloride migration test is currently used; however this cannot provide a conventional solution like total chloride contents since it depicts only ion migration velocity in electrical field. This paper proposes a simple analysis technique for chloride behavior using apparent diffusion coefficient from neural network algorithm with time-dependent diffusion phenomena. For this work, thirty mix proportions of high performance concrete are prepared and their diffusion coefficients are obtained after long term-NaCl submerged test. Considering time-dependent diffusion coefficient based on Fick’s 2nd Law and NNA (neural network algorithm, analysis technique for chloride penetration is proposed. The applicability of the proposed technique is verified through the results from accelerated test, long term submerged test, and field investigation results.

  14. Modeling and experiments for the time-dependent diffusion coefficient during methane desorption from coal

    Science.gov (United States)

    Cheng-Wu, Li; Hong-Lai, Xue; Cheng, Guan; Wen-biao, Liu

    2018-04-01

    Statistical analysis shows that in the coal matrix, the diffusion coefficient for methane is time-varying, and its integral satisfies the formula μt κ /(1 + β κ ). Therefore, a so-called dynamic diffusion coefficient model (DDC model) is developed. To verify the suitability and accuracy of the DDC model, a series of gas diffusion experiments were conducted using coal particles of different sizes. The results show that the experimental data can be accurately described by the DDC and bidisperse models, but the fit to the DDC model is slightly better. For all coal samples, as time increases, the effective diffusion coefficient first shows a sudden drop, followed by a gradual decrease before stabilizing at longer times. The effective diffusion coefficient has a negative relationship with the size of the coal particle. Finally, the relationship between the constants of the DDC model and the effective diffusion coefficient is discussed. The constant α (μ/R 2 ) denotes the effective coefficient at the initial time, and the constants κ and β control the attenuation characteristic of the effective diffusion coefficient.

  15. Mapping human whole-brain structural networks with diffusion MRI.

    Directory of Open Access Journals (Sweden)

    Patric Hagmann

    Full Text Available Understanding the large-scale structural network formed by neurons is a major challenge in system neuroscience. A detailed connectivity map covering the entire brain would therefore be of great value. Based on diffusion MRI, we propose an efficient methodology to generate large, comprehensive and individual white matter connectional datasets of the living or dead, human or animal brain. This non-invasive tool enables us to study the basic and potentially complex network properties of the entire brain. For two human subjects we find that their individual brain networks have an exponential node degree distribution and that their global organization is in the form of a small world.

  16. DETERMINATION OF MOISTURE DIFFUSION COEFFICIENT OF LARCH BOARD WITH FINITE DIFFERENCE METHOD

    Directory of Open Access Journals (Sweden)

    Qiaofang Zhou

    2011-04-01

    Full Text Available This paper deals with the moisture diffusion coefficient of Dahurian Larch (Larix gmelinii Rupr. by use of the Finite Difference Method (FDM. To obtain moisture distributions the dimensional boards of Dahurian Larch were dried, from which test samples were cut and sliced evenly into 9 pieces in different drying periods, so that moisture distributions at different locations and times across the thickness of Dahurian Larch were obtained with a weighing method. With these experimental data, FDM was used to solve Fick’s one-dimensional unsteady-state diffusion equation, and the moisture diffusion coefficient across the thickness at specified time was obtained. Results indicated that the moisture diffusion coefficient decreased from the surface to the center of the Dahurian Larch wood, and it decreased with decreasing moisture content at constant wood temperature; as the wood temperature increased, the moisture diffusion coefficient increased, and the effect of the wood temperature on the moisture diffusion coefficient was more significant than that of moisture content. Moisture diffusion coefficients were different for the two experiments due to differing diffusivity of the specimens.

  17. Diffusion coefficients for unattached decay products of thoron - dependence on ventilation and relative humidity

    International Nuclear Information System (INIS)

    Kotrappa, P.; Bhanti, D.P.; Raghunath, B.

    1976-01-01

    The results of a study of the diffusivity of unattached decay products of thoron with respect to air changes using a recently developed diffusion sampler are reported. The dependence of diffusivity of radon/thoron decay products on relative humidity has also been investigated by measurement of diffusion coefficients in an atmosphere where relative humidities varied from 5 to 90%. Results are shown tabulated. (U.K.)

  18. Comparison of diffusion-weighted fMRI and BOLD fMRI responses in a verbal working memory task

    International Nuclear Information System (INIS)

    Aso, Toshihiko; Urayama, Shin-ichi; Fukuyama, Hidenao; Le Bihan, Denis

    2013-01-01

    Diffusion-weighted functional MRI (DfMRI) has been reported to have a different response pattern in the visual cortex than that of BOLD-fMRI. Especially, the DfMRI signal shows a constantly faster response at both onset and offset of the stimulus, suggesting that the DfMRI signal might be more directly linked to neuronal events than the hemodynamic response. However, because the DfMRI response also contains a residual sensitivity to BOLD this hypothesis has been challenged. Using a verbal working memory task we show that the DfMRI time-course features are preserved outside visual cortices, but also less liable to between-subject/between-regional variation than the BOLD response. The overall findings not only support the feasibility of DfMRI as an approach for functional brain imaging, but also strengthen the uniqueness of the DfMRI signal origin. (authors)

  19. Diffusion-weighted (DW) MRI in lung cancers. ADC test-retest repeatability

    Energy Technology Data Exchange (ETDEWEB)

    Weller, Alex; Papoutsaki, Marianthi Vasiliki; Blackledge, Matthew; DeSouza, Nandita M. [Institute of Cancer Research and Royal Marsden NHS Foundation Trust, CRUK Cancer Imaging Centre, Surrey (United Kingdom); Waterton, John C. [University of Manchester, Manchester (United Kingdom); Chiti, Arturo [Humanitas University, Milan (Italy); Stroobants, Sigrid [Universiteit Antwerpen, Antwerpen (Belgium); Kuijer, Joost [Vrije Universiteit Medisch Centrum, Amsterdam (Netherlands); Morgan, Veronica [Royal Marsden NHS Foundation Trust, Department of Medicine, London (United Kingdom)

    2017-11-15

    To determine the test-retest repeatability of Apparent Diffusion Coefficient (ADC) measurements across institutions and MRI vendors, plus investigate the effect of post-processing methodology on measurement precision. Thirty malignant lung lesions >2 cm in size (23 patients) were scanned on two occasions, using echo-planar-Diffusion-Weighted (DW)-MRI to derive whole-tumour ADC (b = 100, 500 and 800 s/mm{sup -2}). Scanning was performed at 4 institutions (3 MRI vendors). Whole-tumour volumes-of-interest were copied from first visit onto second visit images and from one post-processing platform to an open-source platform, to assess ADC repeatability and cross-platform reproducibility. Whole-tumour ADC values ranged from 0.66-1.94x10{sup -3} mm{sup 2}s{sup -1} (mean = 1.14). Within-patient coefficient-of-variation (wCV) was 7.1% (95% CI 5.7-9.6%), limits-of-agreement (LoA) -18.0 to 21.9%. Lesions >3 cm had improved repeatability: wCV 3.9% (95% CI 2.9-5.9%); and LoA -10.2 to 11.4%. Variability for lesions <3 cm was 2.46 times higher. ADC reproducibility across different post-processing platforms was excellent: Pearson's R{sup 2} = 0.99; CoV 2.8% (95% CI 2.3-3.4%); and LoA -7.4 to 8.0%. A free-breathing DW-MRI protocol for imaging malignant lung tumours achieved satisfactory within-patient repeatability and was robust to changes in post-processing software, justifying its use in multi-centre trials. For response evaluation in individual patients, a change in ADC >21.9% will reflect treatment-related change. (orig.)

  20. DCCO and SCCO: measurements of diffusion coefficients and of thermodiffusion in microgravity; DCCO et SCCO: mesures de coefficients de diffusion et de thermodiffusion en microgravite

    Energy Technology Data Exchange (ETDEWEB)

    Legros, J.C.; Van Vaerenbergh, S.; Dubois, F.; Decroly, Y. [Universite Libre de Bruxelles (Belgium); Montel, F. [ELF-Aquitaine Production, 64 - Pau (France); Goodman, S. [C-CORE, New Foundland, (Canada); Bekaert, G. [SABCA, Bruxelles (Belgium); Van Ransbeek, E. [IASB-BIRA, Bruxelles (Belgium)

    1996-12-31

    Measurements of diffusion coefficients of ternary systems and of thermodiffusion coefficients of multicomponent systems, including crude oils, have been undertaken by MRC and Elf-Aquitaine. The experiments DCCO and SCCO (respectively Diffusion and Soret Coefficients of Crude Oils) will be performed in 1997 and 1998 in GAS containers on the Space Shuttle. The 9 systems of DCCO are analyzed by Mach-Zehnder bicolor interferometry. The samples of the 18 systems of SCCO, among which three at 300 bars and at a mean temperature of 60 deg. C, will be analyzed after recovery on ground by a chromatographic technique. Such measurements performed in microgravity, like the measurements of Soret coefficients of binary solutions performed in the microgravity SCM experiments, are necessary reference measurements. (authors) 12 refs.

  1. Comparison of Biomarkers in Transgenic Alzheimer Rats Using Multi-shell Diffusion MRI

    OpenAIRE

    Fick , Rutger ,; Daianu , Madelaine; Pizzolato , Marco; Wassermann , Demian; Jacobs , Russel E.; Thompson , Paul M.; Town , Terrence; Deriche , Rachid

    2016-01-01

    International audience; In this study, we assessed the evolution of diffusion MRI (dMRI) derived markers from different white matter models as progressive neurodegeneration occurs in transgenic Alzheimer rats (TgF344-AD) at 10, 15 and 24 months. We compared biomarkers reconstructed from Diffusion Tensor Imaging (DTI), Neurite Orientation Dispersion and Density Imaging (NODDI) and Mean Apparent Propagator (MAP)-MRI in the hippocampus, cingulate cortex and corpus callosum using multi-shell dMRI...

  2. An improved procedure for determining grain boundary diffusion coefficients from averaged concentration profiles

    Science.gov (United States)

    Gryaznov, D.; Fleig, J.; Maier, J.

    2008-03-01

    Whipple's solution of the problem of grain boundary diffusion and Le Claire's relation, which is often used to determine grain boundary diffusion coefficients, are examined for a broad range of ratios of grain boundary to bulk diffusivities Δ and diffusion times t. Different reasons leading to errors in determining the grain boundary diffusivity (DGB) when using Le Claire's relation are discussed. It is shown that nonlinearities of the diffusion profiles in lnCav-y6/5 plots and deviations from "Le Claire's constant" (-0.78) are the major error sources (Cav=averaged concentration, y =coordinate in diffusion direction). An improved relation (replacing Le Claire's constant) is suggested for analyzing diffusion profiles particularly suited for small diffusion lengths (short times) as often required in diffusion experiments on nanocrystalline materials.

  3. What’s the clinical significance of adding diffusion and perfusion MRI in the differentiation of glioblastoma multiforme and solitary brain metastasis?

    Directory of Open Access Journals (Sweden)

    Amr F. Mourad

    2017-09-01

    Full Text Available Objective: To evaluate the additional diagnostic value of diffusion and perfusion MRI in the differentiation of glioblastoma multiforme (GBM and solitary brain metastasis. Patients and methods: This retrospective study included 24 patients with histologically proven brain tumors who underwent conventional MRI with analysis of diffusion (DWI and perfusion (PWI MRI findings of each tumor. The Apparent Diffusion Coefficient (ADC values were calculated in the minimum (ADC-MIN, mean (ADC-MEAN, and maximum (ADC-MAX in all the tumors and the peritumoral regions. The PWI data was expressed as maximum regional cerebral blood volume (rCBV of the tumors and peritumoral regions. Results: After adding diffusion and perfusion to conventional MRI findings, we found that the accuracy of differentiation between glioblastoma multiforme (GBM and solitary metastasis increased from 70% to 90%.There is a significant difference in DWI signal intensity between GBM and metastatic tumors (P < 0.05. The ADC values of GBM were lower than that of metastatic tumors. On perfusion MRI, the maximum rCBV of the peritumoral region (rCBVP of GBM was higher than that of brain metastases (P < 0.001. Conclusion: The addition of diffusion and perfusion to the MRI protocol increases the accuracy of differentiation between GBM and solitary brain metastasis and should be considered routinely. Keywords: Diffusion MRI, Perfusion MRI, GBM, Solitary brain metastases

  4. Scale dependence of the effective matrix diffusion coefficient: Evidence and preliminary interpretation

    International Nuclear Information System (INIS)

    Liu, Hui-Hai; Zhang, Yingqi; Molz, Fred J.

    2006-01-01

    The exchange of solute mass (through molecular diffusion) between fluid in fractures and fluid in the rock matrix is called matrix diffusion. Owing to the orders-of-magnitude slower flow velocity in the matrix compared to fractures, matrix diffusion can significantly retard solute transport in fractured rock, and therefore is an important process for a variety of problems, including remediation of subsurface contamination and geological disposal of nuclear waste. The effective matrix diffusion coefficient (molecular diffusion coefficient in free water multiplied by matrix tortuosity) is an important parameter for describing matrix diffusion, and in many cases largely determines overall solute transport behavior. While matrix diffusion coefficient values measured from small rock samples in the laboratory are generally used for modeling field-scale solute transport in fractured rock (Boving and Grathwohl, 2001), several research groups recently have independently found that effective matrix diffusion coefficients much larger than laboratory measurements are needed to match field-scale tracer-test data (Neretnieks, 2002; Becker and Shapiro, 2000; Shapiro, 2001; Liu et al., 2003, 2004a). In addition to the observed enhancement, Liu et al. (2004b), based on a relatively small number of field-test results, reported that the effective matrix diffusion coefficient might be scale dependent, and, like permeability and dispersivity, it seems to increases with test scale. This scale-dependence has important implications for large-scale solute transport in fractured rock. Although a number of mechanisms have been proposed to explain the enhancement of the effective matrix diffusion coefficient, the potential scale dependence and its mechanisms are not fully investigated at this stage. The major objective of this study is to again demonstrate (based on more data published in the literature than those used in Liu et al. [2004b]) the potential scale dependence of the effective

  5. Scale Dependence of the Effective Matrix Diffusion Coefficient : Evidence and Preliminary Interpretation

    International Nuclear Information System (INIS)

    H.H. Liu; Y. Zhang

    2006-01-01

    The exchange of solute mass (through molecular diffusion) between fluid in fractures and fluid in the rock matrix is called matrix diffusion. Owing to the orders-of-magnitude slower flow velocity in the matrix compared to fractures, matrix diffusion can significantly retard solute transport in fractured rock, and therefore is an important process for a variety of problems, including remediation of subsurface contamination and geological disposal of nuclear waste. The effective matrix diffusion coefficient (molecular diffusion coefficient in free water multiplied by matrix tortuosity) is an important parameter for describing matrix diffusion, and in many cases largely determines overall solute transport behavior. While matrix diffusion coefficient values measured from small rock samples in the laboratory are generally used for modeling field-scale solute transport in fractured rock (Boving and Grathwohl, 2001), several research groups recently have independently found that effective matrix diffusion coefficients much larger than laboratory measurements are needed to match field-scale tracer-test data (Neretnieks, 2002; Becker and Shapiro, 2000; Shapiro, 2001; Liu et al., 2003,2004a). In addition to the observed enhancement, Liu et al. (2004b), based on a relatively small number of field-test results, reported that the effective matrix diffusion coefficient might be scale dependent, and, like permeability and dispersivity, it seems to increases with test scale. This scale-dependence has important implications for large-scale solute transport in fractured rock. Although a number of mechanisms have been proposed to explain the enhancement of the effective matrix diffusion coefficient, the potential scale dependence and its mechanisms are not fully investigated at this stage. The major objective of this study is to again demonstrate (based on more data published in the literature than those used in Liu et al. [2004b]) the potential scale dependence of the effective

  6. Fast and direct detection of neuronal activation with diffusion MRI

    Energy Technology Data Exchange (ETDEWEB)

    Le Bihan, D. [Service Hospitalier Frederic Joliot (CEA/DSV/DRM), Lab. Anatomical and Functional Neuroimaging, 91 - Orsay (France); Urayama, S.; Aso, T.; Hanakawa, T.; Fukuyama, H. [Kyoto Univ. Graduate School of Medicine, Human Brain Research Center, Kyoto (Japan)

    2006-07-01

    pathological conditions or in the presence of drugs. Also, it has been pointed out that the spatial functional resolution of vascular based functional neuroimaging might be limited, because vessels responsible for the increase of blood flow and blood volume feed or drain somewhat large territories which include clusters of neurons with potentially different functions. Similarly the physiological delay necessary for the mechanisms triggering the vascular response to work intrinsically limits the temporal resolution of BOLD f MRI. On the other hand, a fundamentally new paradigm is being proposed to look at brain activity through the observation with MRI of the diffusion behavior of the water molecules. It has been shown that the diffusion of water slightly slows down during brain activation. This slowdown, which occurs several seconds before the hemodynamic response detected by BOLD f MRI, has been described in terms of a phase transition of the water molecules in the cells undergoing activation and tentatively attributed to the swelling of those cells. This finding marks a significant departure from the former blood flow based PET and MRI approaches, and potentially offers improved spatial and temporal resolution, because the proposed mechanism appears more intimately linked to neuronal activation. However, the step might even extend further: Contrarily to the former approaches based on changes in artificially induced water physical properties, namely radioactivity and magnetization, required for the external PET or MR I detection, the new, diffusion based approach, merely uses MRI as a means to reveal changes in intrinsic water physical properties. These changes in the diffusion behaviour of water during activation seem to belong to an endogenous part of the activation process, and perhaps even more, could be an active component of this process that evolution has capitalized upon. The aim of this presentation is to review our current knowledge on the water physical properties

  7. Robust and fast nonlinear optimization of diffusion MRI microstructure models.

    Science.gov (United States)

    Harms, R L; Fritz, F J; Tobisch, A; Goebel, R; Roebroeck, A

    2017-07-15

    Advances in biophysical multi-compartment modeling for diffusion MRI (dMRI) have gained popularity because of greater specificity than DTI in relating the dMRI signal to underlying cellular microstructure. A large range of these diffusion microstructure models have been developed and each of the popular models comes with its own, often different, optimization algorithm, noise model and initialization strategy to estimate its parameter maps. Since data fit, accuracy and precision is hard to verify, this creates additional challenges to comparability and generalization of results from diffusion microstructure models. In addition, non-linear optimization is computationally expensive leading to very long run times, which can be prohibitive in large group or population studies. In this technical note we investigate the performance of several optimization algorithms and initialization strategies over a few of the most popular diffusion microstructure models, including NODDI and CHARMED. We evaluate whether a single well performing optimization approach exists that could be applied to many models and would equate both run time and fit aspects. All models, algorithms and strategies were implemented on the Graphics Processing Unit (GPU) to remove run time constraints, with which we achieve whole brain dataset fits in seconds to minutes. We then evaluated fit, accuracy, precision and run time for different models of differing complexity against three common optimization algorithms and three parameter initialization strategies. Variability of the achieved quality of fit in actual data was evaluated on ten subjects of each of two population studies with a different acquisition protocol. We find that optimization algorithms and multi-step optimization approaches have a considerable influence on performance and stability over subjects and over acquisition protocols. The gradient-free Powell conjugate-direction algorithm was found to outperform other common algorithms in terms of

  8. Self-diffusion coefficients of the metastable Lennard-Jones vapor

    International Nuclear Information System (INIS)

    Nie Chu; Zhou Youhua; Marlow, W H; Hassan, Y A

    2008-01-01

    Self-diffusion coefficients of a metastable Lennard-Jones vapor were obtained using the memory function formalism and the frequency moments of the velocity autocorrelation function at reduced temperatures from 0.75 to 1.0. The radial density distribution functions used to evaluate the second, fourth and sixth frequency moments of the velocity autocorrelation function were obtained from the restricted canonical ensemble Monte Carlo simulation (Corti and Debenedetti 1994 Chem. Eng. Sci. 49 2717). The self-diffusion coefficients at reduced temperature 0.75 do not vary monotonically as the density increases, and for the other three temperatures the self-diffusion coefficients vary normally

  9. Self-diffusion coefficients of the metastable Lennard-Jones vapor

    Energy Technology Data Exchange (ETDEWEB)

    Nie Chu; Zhou Youhua [School of Physics and Information Engineering, Jianghan University, Wuhan 430056 (China); Marlow, W H; Hassan, Y A [Department of Nuclear Engineering, Texas A and M University, College Station, TX 77843 (United States)], E-mail: yhzhou@jhun.edu.cn

    2008-10-15

    Self-diffusion coefficients of a metastable Lennard-Jones vapor were obtained using the memory function formalism and the frequency moments of the velocity autocorrelation function at reduced temperatures from 0.75 to 1.0. The radial density distribution functions used to evaluate the second, fourth and sixth frequency moments of the velocity autocorrelation function were obtained from the restricted canonical ensemble Monte Carlo simulation (Corti and Debenedetti 1994 Chem. Eng. Sci. 49 2717). The self-diffusion coefficients at reduced temperature 0.75 do not vary monotonically as the density increases, and for the other three temperatures the self-diffusion coefficients vary normally.

  10. Investigation of a phantom for diffusion weighted imaging that controlled the apparent diffusion coefficient using gelatin and sucrose

    International Nuclear Information System (INIS)

    Tamura, Takayuki; Usui, Shuji; Akiyama, Mitoshi

    2009-01-01

    When studying diffusion weighted imaging (DWI), it is important to create a phantom that has a reliably controlled diffusion coefficient. In this study, we investigated phantoms to control both the diffusion coefficient and the T2-value by changing the concentration of gelatin or sucrose and MnCl 2 , respectively. The results showed that the diffusion coefficient decreased linearly with increases in the gelatin or sucrose concentration, and decreasing of their relaxation times was observed. By properly adjusting the MnCl 2 concentrations, we were able to equalize the T2-values between phantoms having different gelatin or sucrose concentrations. Temperature dependence of the diffusion coefficient was also revealed. This phantom can be made stable for a few months by adding a small amount of NaN 3 as an antiseptic agent, has a diffusion coefficient similar to that of neural tissue or clinical tumor, and is able to control the T2-value properly. We consider this phantom suitable for studying SE-type DWI and contributes to elucidation of this technique. (author)

  11. Rotationally invariant clustering of diffusion MRI data using spherical harmonics

    DEFF Research Database (Denmark)

    Liptrot, Matthew George; Lauze, Francois Bernard

    2016-01-01

    simple features that are invariant to the rotation of the highly orientational diffusion data. This provides a way to directly classify voxels whose diffusion characteristics are similar yet whose primary diffusion orientations differ. Subsequent application of machine-learning to the spherical harmonic...... data as a collection of spherical basis functions. We use the derived coefficients as voxelwise feature vectors for classification. Using a simple Gaussian mixture model, we examined the classification performance for a range of sub-classes (3-20). The results were compared against existing...... classification of DWI data can be performed without the need for a model reconstruction step. This avoids the potential confounds and uncertainty that such models may impose, and has the benefit of being computable directly from the DWI volumes. As such, the method could prove useful in subsequent pre...

  12. Banded Structures in Electron Pitch Angle Diffusion Coefficients from Resonant Wave Particle Interactions

    Science.gov (United States)

    Tripathi, A. K.; Singhal, R. P.; Khazanov, G. V.; Avanov, L. A.

    2016-01-01

    Electron pitch angle (D (alpha)) and momentum (D(pp)) diffusion coefficients have been calculated due to resonant interactions with electrostatic electron cyclotron harmonic (ECH) and whistler mode chorus waves. Calculations have been performed at two spatial locations L = 4.6 and 6.8 for electron energies 10 keV. Landau (n = 0) resonance and cyclotron harmonic resonances n = +/-1, +/-2,...+/-5 have been included in the calculations. It is found that diffusion coefficient versus pitch angle (alpha) profiles show large dips and oscillations or banded structures. The structures are more pronounced for ECH and lower band chorus (LBC) and particularly at location 4.6. Calculations of diffusion coefficients have also been performed for individual resonances. It is noticed that the main contribution of ECH waves in pitch angle diffusion coefficient is due to resonances n = +1 and n = +2. A major contribution to momentum diffusion coefficients appears from n = +2. However, the banded structures in D alpha and Dpp coefficients appear only in the profile of diffusion coefficients for n = +2. The contribution of other resonances to diffusion coefficients is found to be, in general, quite small or even negligible. For LBC and upper band chorus waves, the banded structures appear only in Landau resonance. The Dpp diffusion coefficient for ECH waves is one to two orders smaller than D alpha coefficients. For chorus waves, Dpp coefficients are about an order of magnitude smaller than D alpha coefficients for the case n does not = 0. In case of Landau resonance, the values of Dpp coefficient are generally larger than the values of D alpha coefficients particularly at lower energies. As an aid to the interpretation of results, we have also determined the resonant frequencies. For ECH waves, resonant frequencies have been estimated for wave normal angle 89 deg and harmonic resonances n = +1, +2, and +3, whereas for whistler mode waves, the frequencies have been calculated for angle

  13. Banded Structures in Electron Pitch Angle Diffusion Coefficients from Resonant Wave-Particle Interactions

    Science.gov (United States)

    Tripathi, A. K.; Singhal, R. P.; Khazanov, G. V.; Avanov, L. A.

    2016-01-01

    Electron pitch angle (D(sub (alpha alpha))) and momentum (D(sub pp)) diffusion coefficients have been calculated due to resonant interactions with electrostatic electron cyclotron harmonic (ECH) and whistler mode chorus waves. Calculations have been performed at two spatial locations L=4.6 and 6.8 for electron energies less than or equal to 10 keV. Landau (n=0) resonance and cyclotron harmonic resonances n= +/- 1, +/-2, ... +/-5 have been included in the calculations. It is found that diffusion coefficient versus pitch angle (alpha) profiles show large dips and oscillations or banded structures. The structures are more pronounced for ECH and lower band chorus (LBC) and particularly at location 4.6. Calculations of diffusion coefficients have also been performed for individual resonances. It is noticed that the main contribution of ECH waves in pitch angle diffusion coefficient is due to resonances n=+1 and n=+2. A major contribution to momentum diffusion coefficients appears from n=+2. However, the banded structures in D(sub alpha alpha) and D(sub pp) coefficients appear only in the profile of diffusion coefficients for n=+2. The contribution of other resonances to diffusion coefficients is found to be, in general, quite small or even negligible. For LBC and upper band chorus waves, the banded structures appear only in Landau resonance. The D(sub pp) diffusion coefficient for ECH waves is one to two orders smaller than D(sub alpha alpha) coefficients. For chorus waves, D(sub pp) coefficients are about an order of magnitude smaller than D(sub alpha alpha) coefficients for the case n does not equal 0. In case of Landau resonance, the values of D(sub pp) coefficient are generally larger than the values of D(sub alpha alpha) coefficients particularly at lower energies. As an aid to the interpretation of results, we have also determined the resonant frequencies. For ECH waves, resonant frequencies have been estimated for wave normal angle 89 deg and harmonic resonances

  14. Diffusion-weighted MRI of adult male pelvic cancers

    International Nuclear Information System (INIS)

    Lim, K.S.; Tan, C.H.

    2012-01-01

    Magnetic resonance imaging (MRI), with its superior soft-tissue delineation, plays a pivotal role in the staging and surveillance of cancers affecting adult males, in particular, rectal, urinary bladder, and prostate cancers. There has been much recent interest in the complementary roles of diffusion-weighted imaging (DWI) for imaging of pelvic cancers. DWI measures the diffusivity of water molecules in biological tissue. Cancer, with its high cellular density and nuclear:cytoplasmic ratio, and extracellular disorganization, typically shows significant restricted diffusivity compared with surrounding normal tissue. In theory, diffusivity of water molecules may vary according to degree of tumour aggressiveness and changes in cell density and extracellular fluid content after treatment. Information regarding these variations may be used to study the histological grades of cancers and their response to treatment. In this article, we present the currently available evidence on the potential roles of DWI for the assessment of pelvic cancers in men, and demonstrate with imaging examples how this knowledge may be applied to daily clinical practice.

  15. Contribution to the evaluation of diffusion coefficients in plasmas containing argon and fluorine

    International Nuclear Information System (INIS)

    Novakovic, N V

    2006-01-01

    The theoretical values of the numerical evaluation of the electron and ion diffusion coefficients in plasmas from mixtures of argon and fluorine are presented. The temperature dependence of the diffusion coefficients for low-pressure (from 0.1 to 1.0 kPa) and low-temperature (from 500 to 5000 K) argon plasmas with 20% and 30% of added fluorine are investigated. These values are results of the applications of the specific numerical model to the evaluation plasma composition and transport coefficients in argon plasma with fluorine as additive. It is assumed that the system is kept under constant pressure and that a corresponding state of local thermodynamical equilibrium (LTE) is attained. Since the LTE can be assumed, a Maxwellian electron distribution function will be adopted. The hypothesis of LTE, which is commonly used in most of the numerical evaluations, is analysed with the modified Debye radius r D *. The binary electron and ion diffusion coefficients are calculated with the equilibrium plasma composition and with the collision frequencies. Strictly speaking, Maxwellian distribution function (in the state LTE) is not valid for low pressure, but in this case with the aid of the modified Debye radius, a Maxwellian f e M is assumed correctly. It is shown that the electron diffusion coefficients are about four orders of magnitude larger than the corresponding overall diffusion coefficients of ions. Both diffusion coefficients are lower in argon plasma with 30% than with 20% of fluorine additives, in the whole temperature range examined

  16. Extracting surface diffusion coefficients from batch adsorption measurement data: application of the classic Langmuir kinetics model.

    Science.gov (United States)

    Chu, Khim Hoong

    2017-11-09

    Surface diffusion coefficients may be estimated by fitting solutions of a diffusion model to batch kinetic data. For non-linear systems, a numerical solution of the diffusion model's governing equations is generally required. We report here the application of the classic Langmuir kinetics model to extract surface diffusion coefficients from batch kinetic data. The use of the Langmuir kinetics model in lieu of the conventional surface diffusion model allows derivation of an analytical expression. The parameter estimation procedure requires determining the Langmuir rate coefficient from which the pertinent surface diffusion coefficient is calculated. Surface diffusion coefficients within the 10 -9 to 10 -6  cm 2 /s range obtained by fitting the Langmuir kinetics model to experimental kinetic data taken from the literature are found to be consistent with the corresponding values obtained from the traditional surface diffusion model. The virtue of this simplified parameter estimation method is that it reduces the computational complexity as the analytical expression involves only an algebraic equation in closed form which is easily evaluated by spreadsheet computation.

  17. Maxwell-Stefan diffusion coefficient estimation for ternary systems: an ideal ternary alcohol system.

    Science.gov (United States)

    Allie-Ebrahim, Tariq; Zhu, Qingyu; Bräuer, Pierre; Moggridge, Geoff D; D'Agostino, Carmine

    2017-06-21

    The Maxwell-Stefan model is a popular diffusion model originally developed to model diffusion of gases, which can be considered thermodynamically ideal mixtures, although its application has been extended to model diffusion in non-ideal liquid mixtures as well. A drawback of the model is that it requires the Maxwell-Stefan diffusion coefficients, which are not based on measurable quantities but they have to be estimated. As a result, numerous estimation methods, such as the Darken model, have been proposed to estimate these diffusion coefficients. However, the Darken model was derived, and is only well defined, for binary systems. This model has been extended to ternary systems according to two proposed forms, one by R. Krishna and J. M. van Baten, Ind. Eng. Chem. Res., 2005, 44, 6939-6947 and the other by X. Liu, T. J. H. Vlugt and A. Bardow, Ind. Eng. Chem. Res., 2011, 50, 10350-10358. In this paper, the two forms have been analysed against the ideal ternary system of methanol/butan-1-ol/propan-1-ol and using experimental values of self-diffusion coefficients. In particular, using pulsed gradient stimulated echo nuclear magnetic resonance (PGSTE-NMR) we have measured the self-diffusion coefficients in various methanol/butan-1-ol/propan-1-ol mixtures. The experimental values of self-diffusion coefficients were then used as the input data required for the Darken model. The predictions of the two proposed multicomponent forms of this model were then compared to experimental values of mutual diffusion coefficients for the ideal alcohol ternary system. This experimental-based approach showed that the Liu's model gives better predictions compared to that of Krishna and van Baten, although it was only accurate to within 26%. Nonetheless, the multicomponent Darken model in conjunction with self-diffusion measurements from PGSTE-NMR represents an attractive method for a rapid estimation of mutual diffusion in multicomponent systems, especially when compared to exhaustive

  18. Comparison of Experimental Methods for Estimating Matrix Diffusion Coefficients for Contaminant Transport Modeling

    Energy Technology Data Exchange (ETDEWEB)

    Telfeyan, Katherine Christina [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Ware, Stuart Douglas [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Reimus, Paul William [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Birdsell, Kay Hanson [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-11-06

    Diffusion cell and diffusion wafer experiments were conducted to compare methods for estimating matrix diffusion coefficients in rock core samples from Pahute Mesa at the Nevada Nuclear Security Site (NNSS). A diffusion wafer method, in which a solute diffuses out of a rock matrix that is pre-saturated with water containing the solute, is presented as a simpler alternative to the traditional through-diffusion (diffusion cell) method. Both methods yielded estimates of matrix diffusion coefficients that were within the range of values previously reported for NNSS volcanic rocks. The difference between the estimates of the two methods ranged from 14 to 30%, and there was no systematic high or low bias of one method relative to the other. From a transport modeling perspective, these differences are relatively minor when one considers that other variables (e.g., fracture apertures, fracture spacings) influence matrix diffusion to a greater degree and tend to have greater uncertainty than diffusion coefficients. For the same relative random errors in concentration measurements, the diffusion cell method yields diffusion coefficient estimates that have less uncertainty than the wafer method. However, the wafer method is easier and less costly to implement and yields estimates more quickly, thus allowing a greater number of samples to be analyzed for the same cost and time. Given the relatively good agreement between the methods, and the lack of any apparent bias between the methods, the diffusion wafer method appears to offer advantages over the diffusion cell method if better statistical representation of a given set of rock samples is desired.

  19. Comparison of experimental methods for estimating matrix diffusion coefficients for contaminant transport modeling

    Science.gov (United States)

    Telfeyan, Katherine; Ware, S. Doug; Reimus, Paul W.; Birdsell, Kay H.

    2018-02-01

    Diffusion cell and diffusion wafer experiments were conducted to compare methods for estimating effective matrix diffusion coefficients in rock core samples from Pahute Mesa at the Nevada Nuclear Security Site (NNSS). A diffusion wafer method, in which a solute diffuses out of a rock matrix that is pre-saturated with water containing the solute, is presented as a simpler alternative to the traditional through-diffusion (diffusion cell) method. Both methods yielded estimates of effective matrix diffusion coefficients that were within the range of values previously reported for NNSS volcanic rocks. The difference between the estimates of the two methods ranged from 14 to 30%, and there was no systematic high or low bias of one method relative to the other. From a transport modeling perspective, these differences are relatively minor when one considers that other variables (e.g., fracture apertures, fracture spacings) influence matrix diffusion to a greater degree and tend to have greater uncertainty than effective matrix diffusion coefficients. For the same relative random errors in concentration measurements, the diffusion cell method yields effective matrix diffusion coefficient estimates that have less uncertainty than the wafer method. However, the wafer method is easier and less costly to implement and yields estimates more quickly, thus allowing a greater number of samples to be analyzed for the same cost and time. Given the relatively good agreement between the methods, and the lack of any apparent bias between the methods, the diffusion wafer method appears to offer advantages over the diffusion cell method if better statistical representation of a given set of rock samples is desired.

  20. A 4-channel 3 Tesla phased array receive coil for awake rhesus monkey fMRI and diffusion MRI experiments.

    Science.gov (United States)

    Khachaturian, Mark Haig

    2010-01-01

    Awake monkey fMRI and diffusion MRI combined with conventional neuroscience techniques has the potential to study the structural and functional neural network. The majority of monkey fMRI and diffusion MRI experiments are performed with single coils which suffer from severe EPI distortions which limit resolution. By constructing phased array coils for monkey MRI studies, gains in SNR and anatomical accuracy (i.e., reduction of EPI distortions) can be achieved using parallel imaging. The major challenges associated with constructing phased array coils for monkeys are the variation in head size and space constraints. Here, we apply phased array technology to a 4-channel phased array coil capable of improving the resolution and image quality of full brain awake monkey fMRI and diffusion MRI experiments. The phased array coil is that can adapt to different rhesus monkey head sizes (ages 4-8) and fits in the limited space provided by monkey stereotactic equipment and provides SNR gains in primary visual cortex and anatomical accuracy in conjunction with parallel imaging and improves resolution in fMRI experiments by a factor of 2 (1.25 mm to 1.0 mm isotropic) and diffusion MRI experiments by a factor of 4 (1.5 mm to 0.9 mm isotropic).

  1. Apparent diffusion coefficient as it relates to histopathology findings in post-chemotherapy nephroblastoma: a feasibility study

    Energy Technology Data Exchange (ETDEWEB)

    Littooij, Annemieke S. [University Medical Centre Utrecht/Wilhelmina Children' s Hospital, Department of Radiology and Nuclear Medicine, Utrecht (Netherlands); Nikkels, Peter G. [University Medical Centre Utrecht, Department of Pathology, Utrecht (Netherlands); Hulsbergen-van de Kaa, Christina A. [Radboud University Medical Centre, Department of Pathology, Nijmegen (Netherlands); Ven, Cees P. van de [Princess Maxima Centre for Paediatric Oncology, Department of Paediatric Surgery, Utrecht (Netherlands); Heuvel-Eibrink, Marry M. van den [Princess Maxima Centre for Paediatric Oncology, Department of Paediatric Oncology, Utrecht (Netherlands); Olsen, Oeystein E. [Great Ormond Street Hospital for Children, Department of Radiology, London (United Kingdom)

    2017-11-15

    Nephroblastomas represent a group of heterogeneous tumours with variable proportions of distinct histopathological components. The purpose of this study was to investigate whether direct comparison of apparent diffusion coefficient (ADC) measurements with post-resection histopathology subtypes is feasible and whether ADC metrics are related to histopathological components. Twenty-three children were eligible for inclusion in this retrospective study. All children had MRI including diffusion-weighted imaging (DWI) after preoperative chemotherapy, just before tumour resection. A pathologist and radiologist identified corresponding slices at MRI and postoperative specimens using tumour morphology, the upper/lower calyx and hilar vessels as reference points. An experienced reader performed ADC measurements, excluding non-enhancing areas. A pathologist reviewed the corresponding postoperative slides according to the international standard guidelines. We tested potential associations with the Spearman rank test. Side-by-side comparison of MRI-DWI with corresponding histopathology slides was feasible in 15 transverse slices in 9 lesions in 8 patients. Most exclusions were related to extensive areas of necrosis/haemorrhage. In one lesion correlation was not possible because of the different orientation of sectioning of the specimen and MRI slices. The 25% ADC showed a strong relationship with percentage of blastema (Spearman rho=-0.71, P=0.003), whereas median ADC was strongly related to the percentage stroma (Spearman rho=0.74, P=0.002) at histopathology. Side-by-side comparison of MRI-DWI and histopathology is feasible in the majority of patients who do not have massive necrosis and hemorrhage. Blastemal and stromal components have a strong linear relationship with ADC markers. (orig.)

  2. Comparison of diffusion coefficients and activation energies for AG diffusion in silicon carbide

    International Nuclear Information System (INIS)

    Kim, Bong Goo; Yeo, Sung Hwan; Lee, Young Woo; Cho, Moon Sung

    2015-01-01

    The migration of silver (Ag) in silicon carbide (SiC) and 110mAg through SiC of irradiated tri-structural isotropic (TRISO) fuel has been studied for the past three to four decades. However, there is no satisfactory explanation for the transport mechanism of Ag in SiC. In this work, the diffusion coefficients of Ag measured and/or estimated in previous studies were reviewed, and then pre-exponential factors and activation energies from the previous experiments were evaluated using Arrhenius equation. The activation energy is 247.4 kJ·mol -1 from Ag paste experiments between two SiC layers produced using fluidized-bed chemical vapor deposition (FBCVD), 125.3 kJ·mol -1 from integral release experiments (annealing of irradiated TRISO fuel), 121.8 kJ·mol -1 from fractional Ag release during irradiation of TRISO fuel in high flux reactor (HFR), and 274.8 kJ·mol -1 from Ag ion implantation experiments, respectively. The activation energy from ion implantation experiments is greater than that from Ag paste, fractional release and integral release, and the activation energy from Ag paste experiments is approximately two times greater than that from integral release experiments and fractional Ag release during the irradiation of TRISO fuel in HFR. The pre-exponential factors are also very different depending on the experimental methods and estimation. From a comparison of the pre-exponential factors and activation energies, it can be analogized that the diffusion mechanism of Ag using ion implantation experiment is different from other experiments, such as a Ag paste experiment, integral release experiments, and heating experiments after irradiating TRISO fuel in HFR. However, the results of this work do not support the long held assumption that Ag release from FBCVD-SiC, used for the coating layer in TRISO fuel, is dominated by grain boundary diffusion. In order to understand in detail the transport mechanism of Ag through the coating layer, FBCVD-SiC in TRISO fuel, a

  3. Diffusion-weighted MRI of the prostate; Diffusionsgewichtete MRT der Prostata

    Energy Technology Data Exchange (ETDEWEB)

    Mueller-Lisse, U.G.; Scherr, M.K. [Klinikum der Ludwig-Maximilians-Universitaet Muenchen, Institut fuer Klinische Radiologie, Muenchen (Germany); Mueller-Lisse, U.L. [Klinikum der Ludwig-Maximilians-Universitaet Muenchen, Klinik und Poliklinik fuer Urologie, Muenchen (Germany); Zamecnik, P.; Schlemmer, H.P.W. [Deutsches Krebsforschungszentrum (DKFZ), Abteilung fuer Radiologische Diagnostik, Heidelberg (Germany)

    2011-03-15

    Diffusion-weighted magnetic resonance imaging (DWI) can complement MRI of the prostate in the detection and localization of prostate cancer, particularly after previous negative biopsy. A total of 13 original reports and 2 reviews published in 2010 demonstrate that prostate cancer can be detected by DWI due to its increased cell density and decreased diffusiveness, either qualitatively in DWI images or quantitatively by means of the apparent diffusion coefficient (ADC). In the prostate, the ADC is influenced by the strength of diffusion weighting, localization (peripheral or transitional zone), presence of prostatitis or hemorrhage and density and differentiation of prostate cancer cells. Mean differences between healthy tissue of the peripheral zone and prostate cancer appear to be smaller for ADC than for the (choline + creatine)/citrate ratio in MR spectroscopy. Test quality parameters vary greatly between different studies but appear to be slightly better for combined MRI and DWI than for MRI of the prostate alone. Clinical validation of DWI of the prostate requires both increased technical conformity and increased numbers of patients in clinical studies. (orig.) [German] Die diffusionsgewichtete MRT (''diffusion-weighted imaging'', DWI) kann die MRT der Prostata bei der Erkennung und Lokalisation von Prostatakarzinomen besonders nach vorangehender, negativer Stanzbiopsie ergaenzen. In 13 klinischen Original- und 2 Uebersichtsarbeiten des Jahres 2010 zeigt sich, dass die DWI Prostatakarzinome an Einschraenkungen der freien Teilchenbeweglichkeit bei erhoehter Zelldichte qualitativ im Bild oder quantitativ an Hand des ''apparent diffusion coefficient'' (ADC) nachweist. Den ADC in der Prostata beeinflussen Staerke der Diffusionsgewichtung, Lokalisation (periphere Zone, Transitionalzone), Vorliegen von Prostatitis oder Einblutung sowie Streudichte und Differenzierung von Prostatakarzinomzellen. Unterschiede zwischen gesundem

  4. Automatic classification of patients with idiopathic Parkinson's disease and progressive supranuclear palsy using diffusion MRI datasets

    Science.gov (United States)

    Talai, Sahand; Boelmans, Kai; Sedlacik, Jan; Forkert, Nils D.

    2017-03-01

    Parkinsonian syndromes encompass a spectrum of neurodegenerative diseases, which can be classified into various subtypes. The differentiation of these subtypes is typically conducted based on clinical criteria. Due to the overlap of intra-syndrome symptoms, the accurate differential diagnosis based on clinical guidelines remains a challenge with failure rates up to 25%. The aim of this study is to present an image-based classification method of patients with Parkinson's disease (PD) and patients with progressive supranuclear palsy (PSP), an atypical variant of PD. Therefore, apparent diffusion coefficient (ADC) parameter maps were calculated based on diffusion-tensor magnetic resonance imaging (MRI) datasets. Mean ADC values were determined in 82 brain regions using an atlas-based approach. The extracted mean ADC values for each patient were then used as features for classification using a linear kernel support vector machine classifier. To increase the classification accuracy, a feature selection was performed, which resulted in the top 17 attributes to be used as the final input features. A leave-one-out cross validation based on 56 PD and 21 PSP subjects revealed that the proposed method is capable of differentiating PD and PSP patients with an accuracy of 94.8%. In conclusion, the classification of PD and PSP patients based on ADC features obtained from diffusion MRI datasets is a promising new approach for the differentiation of Parkinsonian syndromes in the broader context of decision support systems.

  5. Determination of diffusion coefficients of various livestock antibiotics in water at infinite dilution

    Directory of Open Access Journals (Sweden)

    Soriano Allan N.

    2017-01-01

    Full Text Available The fate of antibiotics entering the environment raised concerns on the possible effect of antimicrobial resistance bacteria. Prediction of the fate and transport of these particles are needed to be determined, significantly the diffusion coefficient of antibiotic in water at infinite dilution. A systematic determination of diffusion coefficient of antibiotic in water at infinite dilution of five different kinds of livestock antibiotics namely: Amtyl, Ciprotyl, Doxylak Forte, Trisullak, and Vetracin Gold in the 293.15 to 313.15 K temperature range are reported through the use of the method involving the electrolytic conductivity measurements. A continuous stirred tank reactor is utilized to measure the electrolytic conductivities of the considered systems. These conductivities are correlated by using the Nernst-Haskell equation to determine the infinite dilution diffusion coefficient. Determined diffusion coefficients are based on the assumption that in dilute solution, these antibiotics behave as strong electrolyte from which H+ cation dissociate from the antibiotic’s anion.

  6. Determination of diffusion coefficients of various livestock antibiotics in water at infinite dilution

    Science.gov (United States)

    Soriano, Allan N.; Adamos, Kristoni G.; Bonifacio, Pauline B.; Adornado, Adonis P.; Bungay, Vergel C.; Vairavan, Rajendaran

    2017-11-01

    The fate of antibiotics entering the environment raised concerns on the possible effect of antimicrobial resistance bacteria. Prediction of the fate and transport of these particles are needed to be determined, significantly the diffusion coefficient of antibiotic in water at infinite dilution. A systematic determination of diffusion coefficient of antibiotic in water at infinite dilution of five different kinds of livestock antibiotics namely: Amtyl, Ciprotyl, Doxylak Forte, Trisullak, and Vetracin Gold in the 293.15 to 313.15 K temperature range are reported through the use of the method involving the electrolytic conductivity measurements. A continuous stirred tank reactor is utilized to measure the electrolytic conductivities of the considered systems. These conductivities are correlated by using the Nernst-Haskell equation to determine the infinite dilution diffusion coefficient. Determined diffusion coefficients are based on the assumption that in dilute solution, these antibiotics behave as strong electrolyte from which H+ cation dissociate from the antibiotic's anion.

  7. MRI-negative refractory partial epilepsy: role for diffusion tensor imaging in high field MRI.

    Science.gov (United States)

    Chen, Qin; Lui, Su; Li, Chun-Xiao; Jiang, Li-Jun; Ou-Yang, Luo; Tang, He-Han; Shang, Hui-Fang; Huang, Xiao-Qi; Gong, Qi-Yong; Zhou, Dong

    2008-07-01

    Our aim is to use the high field MR scanner (3T) to verify whether diffusion tensor imaging (DTI) could help in locating the epileptogenic zone in patients with MRI-negative refractory partial epilepsy. Fifteen patients with refractory partial epilepsy who had normal conventional MRI, and 40 healthy volunteers were recruited for the study. DTI was performed on a 3T MR scanner, individual maps of mean diffusivity (MD) and fractional anisotropy (FA) were calculated, and Voxel-Based Analysis (VBA) was performed for individual comparison between patients and controls. Voxel-based analysis revealed significant MD increase in variant regions in 13 patients. The electroclinical seizure localization was concurred to seven patients. No patient exhibited regions of significant decreased MD. Regions of significant reduced FA were observed in five patients, with two of these concurring with electroclinical seizure localization. Two patients had regions of significant increase in FA, which were distinct from electroclinical seizure localization. Our study's results revealed that DTI is a responsive neuroradiologic technique that provides information about the epileptogenic areas in patients with MRI-negative refractory partial epilepsy. This technique may also helpful in pre-surgical evaluation.

  8. Determination of the zincate diffusion coefficient and its application to alkaline battery problems

    Science.gov (United States)

    May, C. E.; Kautz, H. E.

    1978-01-01

    The diffusion coefficient for the zincate ion at 24 C was found to be 9.9 x 10 to the -7th power sq cm/sec + or - 30% in 45% potassium hydroxide and 1.4 x 10 to the -7th power sq cm/sec + or - 25% in 40% sodium hydroxide. Comparison of these values with literature values at different potassium hydroxide concentrations show that the Stokes-Einstein equation is obeyed. The diffusion coefficient is characteristic of the zincate ion (not the cation) and independent of its concentration. Calculations with the measured value of the diffusion coefficient show that the zinc concentration in an alkaline zincate half-cell becomes uniform throughout in tens of hours by diffusion alone. Diffusion equations are derived which are applicable to finite-size chambers. Details and discussion of the experimental method are also given.

  9. Determination of the concentration dependent diffusion coefficient of nitrogen in expanded austenite

    DEFF Research Database (Denmark)

    Christiansen, Thomas; Somers, Marcel A. J.

    2008-01-01

    The concentration dependent diffusion coefficient of nitrogen in expanded austenite was determined from of the rate of retracting nitrogen from thin initially N-saturated coupons. Nitrogen saturated homogeneous foils of expanded austenite were obtained by nitriding AISI 304 and AISI 316 in pure...... in the composition range where nitrogen can be extracted by hydrogen gas at the diffusion temperature. Numerical simulation of the denitriding experiments shows that the thus determined concentration dependent diffusion coefficients are an accurate approximation of the actual diffusivity of nitrogen in expanded...... ammonia at 693 K and 718 K. Denitriding experiments were performed by equilibrating the foils with a successively lower nitrogen activity, as imposed by a gas mixture of ammonia and hydrogen. The concentration dependent diffusion coefficient of nitrogen in expanded austenite was approximated...

  10. Carpal tunnel syndrome assessment with diffusion tensor imaging. Value of fractional anisotropy and apparent diffusion coefficient

    Energy Technology Data Exchange (ETDEWEB)

    Klauser, A.S.; Kremser, C. [Medical University of Innsbruck, Department of Radiology, Innsbruck (Austria); Abd Ellah, M. [Medical University of Innsbruck, Department of Radiology, Innsbruck (Austria); Assiut University, Department of Diagnostic Radiology, South Egypt Cancer Institute, Assiut (Egypt); Taljanovic, M. [University of Arizona, College of Medicine, Banner- University Medical Center, Department of Medical Imaging, Tucson (United States); Schmidle, G.; Gabl, M. [Medical University of Innsbruck, Department for Trauma Surgery, Innsbruck (Austria); Cartes-Zumelzu, F.; Steiger, R.; Gizewski, E.R. [Medical University of Innsbruck, Department of Neuroradiology, Neuroimaging core facility, Innsbruck (Austria)

    2018-03-15

    To quantitatively assess carpal tunnel syndrome (CTS) with DTI by evaluating two approaches to determine cut-off values. In forty patients with CTS diagnosis confirmed by nerve conduction studies (NCs) and 14 healthy subjects (mean age 58.54 and 57.8 years), cross-sectional area (CSA), apparent diffusion coefficient (ADC) and fractional anisotropy (FA) at single and multiple levels with intraobserver agreement were evaluated. Maximum and mean CSA and FA showed significant differences between healthy subjects and patients (12.85 mm{sup 2} vs. 28.18 mm{sup 2}, p < 0.001, and 0.613 vs. 0.524, p=0.007, respectively) (10.12 mm{sup 2} vs. 19.9 mm{sup 2}, p<0.001 and 0.617 vs. 0.54, p=0.003, respectively), but not maximum and mean ADC (p > 0.05). For cut-off values, mean and maximum CSA showed the same sensitivity and specificity (93.3 %). However, mean FA showed better sensitivity than maximum FA (82.6 % vs. 73.9 %), but lower specificity (66.7 % vs. 80 %), and significant correlation for maximum CSA, 97 % (p < 0.01), with good correlation for maximum ADC and FA, 84.5 % (p < 0.01) and 62 % (p=0.056), respectively. CSA and FA showed significant differences between healthy subjects and patients. Single measurement at maximum CSA is suitable for FA determination. (orig.)

  11. Diffusion coefficient and Kolmogorov entropy of magnetic field lines

    International Nuclear Information System (INIS)

    Zimbardo, G.; Veltri, P.; Malara, F.

    1984-01-01

    A diffusion equation for magnetic field lines of force in a turbulent magnetic field, which describes both the random walk of a single line and how two nearby lines separate from each other, has been obtained using standard statistical techniques. Starting from such an equation, a closed set of equations for the moments may be obtained, in general, with suitable assumptions. From such a set of equations the Kolmogorov entropy may be explicitly calculated. The results have been applied to the most interesting examples of magnetic field geometries. (author)

  12. FITTING OF THE DATA FOR DIFFUSION COEFFICIENTS IN UNSATURATED POROUS MEDIA

    Energy Technology Data Exchange (ETDEWEB)

    B. Bullard

    1999-05-01

    The purpose of this calculation is to evaluate diffusion coefficients in unsaturated porous media for use in the TSPA-VA analyses. Using experimental data, regression techniques were used to curve fit the diffusion coefficient in unsaturated porous media as a function of volumetric water content. This calculation substantiates the model fit used in Total System Performance Assessment-1995 An Evaluation of the Potential Yucca Mountain Repository (TSPA-1995), Section 6.5.4.

  13. FITTING OF THE DATA FOR DIFFUSION COEFFICIENTS IN UNSATURATED POROUS MEDIA

    International Nuclear Information System (INIS)

    B. Bullard

    1999-01-01

    The purpose of this calculation is to evaluate diffusion coefficients in unsaturated porous media for use in the TSPA-VA analyses. Using experimental data, regression techniques were used to curve fit the diffusion coefficient in unsaturated porous media as a function of volumetric water content. This calculation substantiates the model fit used in Total System Performance Assessment-1995 An Evaluation of the Potential Yucca Mountain Repository (TSPA-1995), Section 6.5.4

  14. The effect of radionuclides and their carriers on diffusion coefficient of radionuclides in local rocks

    International Nuclear Information System (INIS)

    Othman, I.; Takriti, S.

    1995-07-01

    The diffusion coefficient of sup 9 sup 0 Sr and sup 1 sup 3 sup 7 Cs has been calculated for different local rocks in stationary and dynamic state. The effect of pH radioisotope solution dependence in shown by diffusion coefficient in some rocks. The results show that the cement and dolomite have the best quality of radioisotope retention which do not allow them to pollute the environment. (author). 6 refs., 2 tabs., 13 figs

  15. Diffusion coefficients for multi-step persistent random walks on lattices

    International Nuclear Information System (INIS)

    Gilbert, Thomas; Sanders, David P

    2010-01-01

    We calculate the diffusion coefficients of persistent random walks on lattices, where the direction of a walker at a given step depends on the memory of a certain number of previous steps. In particular, we describe a simple method which enables us to obtain explicit expressions for the diffusion coefficients of walks with a two-step memory on different classes of one-, two- and higher dimensional lattices.

  16. The use of CACTUS to generate modified diffusion coefficients in LWRWIMS

    International Nuclear Information System (INIS)

    Halsall, M.J.

    1986-11-01

    A new method has been devised in the lattice code, LWRWIMS, for modifying diffusion coefficients for poison pins. The method is based on an earlier one which used a one dimensional transport calculation of flux gradient and leakage to determine the effective diffusion coefficient. The improvement is to use a two dimensional characteristics transport calculation to overcome the approximations in geometry made previously. The report explains the theory of the method, describes its use within LWRWIMS, and gives some results obtained. (author)

  17. Determination of axial diffusion coefficients by the Monte-Carlo method

    International Nuclear Information System (INIS)

    Milgram, M.

    1994-01-01

    A simple method to calculate the homogenized diffusion coefficient for a lattice cell using Monte-Carlo techniques is demonstrated. The method relies on modelling a finite reactor volume to induce a curvature in the flux distribution, and then follows a large number of histories to obtain sufficient statistics for a meaningful result. The goal is to determine the diffusion coefficient with sufficient accuracy to test approximate methods built into deterministic lattice codes. Numerical results are given. (author). 4 refs., 8 figs

  18. FIELD-SCALE EFFECTIVE MATRIX DIFFUSION COEFFICIENT FOR FRACTURED ROCK: RESULTS FROM LITERATURE SURVEY

    International Nuclear Information System (INIS)

    Zhou, Q.; Hui-Hai Liu; Molz, F.J.; Zhang, Y.; Bodvarsson, G.S.

    2005-01-01

    Matrix diffusion is an important mechanism for solute transport in fractured rock. We recently conducted a literature survey on the effective matrix diffusion coefficient, D m e , a key parameter for describing matrix diffusion processes at the field scale. Forty field tracer tests at 15 fractured geologic sites were surveyed and selected for the study, based on data availability and quality. Field-scale D m e values were calculated, either directly using data reported in the literature or by reanalyzing the corresponding field tracer tests. Surveyed data indicate that the effective-matrix-diffusion-coefficient factor F D (defined as the ratio of D m e to the lab-scale matrix diffusion coefficient [D m ] of the same tracer) is generally larger than one, indicating that the effective matrix diffusion coefficient in the field is comparatively larger than the matrix diffusion coefficient at the rock-core scale. This larger value can be attributed to the many mass-transfer processes at different scales in naturally heterogeneous, fractured rock systems. Furthermore, we observed a moderate trend toward systematic increase in the F D value with observation scale, indicating that the effective matrix diffusion coefficient is likely to be statistically scale dependent. The F D value ranges from 1 to 10,000 for observation scales from 5 to 2,000 m. At a given scale, the F D value varies by two orders of magnitude, reflecting the influence of differing degrees of fractured rock heterogeneity at different sites. In addition, the surveyed data indicate that field-scale longitudinal dispersivity generally increases with observation scale, which is consistent with previous studies. The scale-dependent field-scale matrix diffusion coefficient (and dispersivity) may have significant implications for assessing long-term, large-scale radionuclide and contaminant transport events in fractured rock, both for nuclear waste disposal and contaminant remediation

  19. Apparent diffusion coefficient mapping in medulloblastoma predicts non-infiltrative surgical planes.

    Science.gov (United States)

    Marupudi, Neena I; Altinok, Deniz; Goncalves, Luis; Ham, Steven D; Sood, Sandeep

    2016-11-01

    An appropriate surgical approach for posterior fossa lesions is to start tumor removal from areas with a defined plane to where tumor is infiltrating the brainstem or peduncles. This surgical approach minimizes risk of damage to eloquent areas. Although magnetic resonance imaging (MRI) is the current standard preoperative imaging obtained for diagnosis and surgical planning of pediatric posterior fossa tumors, it offers limited information on the infiltrative planes between tumor and normal structures in patients with medulloblastomas. Because medulloblastomas demonstrate diffusion restriction on apparent diffusion coefficient map (ADC map) sequences, we investigated the role of ADC map in predicting infiltrative and non-infiltrative planes along the brain stem and/or cerebellar peduncles by medulloblastomas prior to surgery. Thirty-four pediatric patients with pathologically confirmed medulloblastomas underwent surgical resection at our facility from 2004 to 2012. An experienced pediatric neuroradiologist reviewed the brain MRIs/ADC map, assessing the planes between the tumor and cerebellar peduncles/brain stem. An independent evaluator documented surgical findings from operative reports for comparison to the radiographic findings. The radiographic findings were statistically compared to the documented intraoperative findings to determine predictive value of the test in identifying tumor infiltration of the brain stem cerebellar peduncles. Twenty-six patients had preoperative ADC mapping completed and thereby, met inclusion criteria. Mean age at time of surgery was 8.3 ± 4.6 years. Positive predictive value of ADC maps to predict tumor invasion of the brain stem and cerebellar peduncles ranged from 69 to 88 %; negative predictive values ranged from 70 to 89 %. Sensitivity approached 93 % while specificity approached 78 %. ADC maps are valuable in predicting the infiltrative and non-infiltrative planes along the tumor and brain stem interface in

  20. Dependence of Exciton Diffusion Length and Diffusion Coefficient on Photophysical Parameters in Bulk Heterojunction Organic Solar Cells

    Science.gov (United States)

    Yeboah, Douglas; Singh, Jai

    2017-11-01

    Recently, the dependence of exciton diffusion length (LD ) on some photophysical parameters of organic solids has been experimentally demonstrated, however no systematic theoretical analysis of this phenomenon has been carried out. We have conducted a theoretical study by using the Förster resonance energy transfer and Dexter carrier transfer mechanisms together with the Einstein-Smoluchowski diffusion equation to derive analytical models for the diffusion lengths (LD ) and diffusion coefficients (D) of singlet (S) and triplet (T) excitons in organic solids as functions of spectral overlap integral (J) , photoluminescence (PL) quantum yield (φD ) , dipole moment (μT ) and refractive index (n) of the photoactive material. The exciton diffusion lengths and diffusion coefficients in some selected organic solids were calculated, and we found that the singlet exciton diffusion length (LDS ) increases with φD and J, and decreases with n. Also, the triplet exciton diffusion length (LDT ) increases with φD and decreases with μT . These may be achieved through doping the organic solids into broad optical energy gap host materials as observed in previous experiments. The calculated exciton diffusion lengths are compared with experimental values and a reasonably good agreement is found between them. The results presented are expected to provide insight relevant to the synthesis of new organic solids for fabrication of bulk heterojunction organic solar cells characterized by better power conversion efficiency.

  1. Imaging of postthalamic visual fiber tracts by anisotropic diffusion weighted MRI and diffusion tensor imaging: principles and applications

    International Nuclear Information System (INIS)

    Reinges, Marcus H.T.; Schoth, Felix; Coenen, Volker A.; Krings, Timo

    2004-01-01

    Diffusion weighted MRI offers the possibility to study the course of the cerebral white matter tracts. In the present manuscript, the basics, the technique and the limitations of diffusion tensor imaging and anisotropic diffusion weighted MRI are presented and their applications in various neurological and neurosurgical diseases are discussed with special emphasis on the visual system. A special focus is laid on the combination of fiber tract imaging, anatomical imaging and functional MRI for presurgical planning and intraoperative neuronavigation of lesions near the visual system

  2. Diffusion Decay Coefficient for Chloride Ions of Concrete Containing Mineral Admixtures

    Directory of Open Access Journals (Sweden)

    Jae-Im Park

    2016-01-01

    Full Text Available The diffusion coefficient for chloride ions and the diffusion decay coefficient for chloride ions are essential variables for a service life evaluation of concrete structures. They are influenced by water-binder ratio, exposure condition, curing temperature, cement type, and the type and use of mineral admixture. Mineral admixtures such as ground granulated blast furnace slag, fly ash, and silica fume have been increasingly used to improve resistance against chloride ions penetration in concrete structures built in an offshore environment. However, there is not enough measured data to identify the statistical properties of diffusion decay coefficient for chloride ions in concrete using mineral admixtures. This paper is aimed at evaluating the diffusion decay coefficient for chloride ions of concrete using ordinary Portland cement or blended cement. NT BUILD 492 method, an electrophoresis experiment, was used to measure the diffusion coefficient for chloride ions with ages. It was revealed from the test results that the diffusion decay coefficient for chloride ions was significantly influenced by W/B and the replacement ratio of mineral admixtures.

  3. Imaging brain microstructure with diffusion MRI: practicality and applications.

    Science.gov (United States)

    Alexander, Daniel C; Dyrby, Tim B; Nilsson, Markus; Zhang, Hui

    2017-11-29

    This article gives an overview of microstructure imaging of the brain with diffusion MRI and reviews the state of the art. The microstructure-imaging paradigm aims to estimate and map microscopic properties of tissue using a model that links these properties to the voxel scale MR signal. Imaging techniques of this type are just starting to make the transition from the technical research domain to wide application in biomedical studies. We focus here on the practicalities of both implementing such techniques and using them in applications. Specifically, the article summarizes the relevant aspects of brain microanatomy and the range of diffusion-weighted MR measurements that provide sensitivity to them. It then reviews the evolution of mathematical and computational models that relate the diffusion MR signal to brain tissue microstructure, as well as the expanding areas of application. Next we focus on practicalities of designing a working microstructure imaging technique: model selection, experiment design, parameter estimation, validation, and the pipeline of development of this class of technique. The article concludes with some future perspectives on opportunities in this topic and expectations on how the field will evolve in the short-to-medium term. Copyright © 2017 John Wiley & Sons, Ltd.

  4. Optimal Parameters to Determine the Apparent Diffusion Coefficient in Diffusion Weighted Imaging via Simulation

    Science.gov (United States)

    Perera, Dimuthu

    Diffusion weighted (DW) Imaging is a non-invasive MR technique that provides information about the tissue microstructure using the diffusion of water molecules. The diffusion is generally characterized by the apparent diffusion coefficient (ADC) parametric map. The purpose of this study is to investigate in silico how the calculation of ADC is affected by image SNR, b-values, and the true tissue ADC. Also, to provide optimal parameter combination depending on the percentage accuracy and precision for prostate peripheral region cancer application. Moreover, to suggest parameter choices for any type of tissue, while providing the expected accuracy and precision. In this research DW images were generated assuming a mono-exponential signal model at two different b-values and for known true ADC values. Rician noise of different levels was added to the DWI images to adjust the image SNR. Using the two DWI images, ADC was calculated using a mono-exponential model for each set of b-values, SNR, and true ADC. 40,000 ADC data were collected for each parameter setting to determine the mean and the standard-deviation of the calculated ADC, as well as the percentage accuracy and precision with respect to the true ADC. The accuracy was calculated using the difference between known and calculated ADC. The precision was calculated using the standard-deviation of calculated ADC. The optimal parameters for a specific study was determined when both the percentage accuracy and precision were minimized. In our study, we simulated two true ADCs (ADC 0.00102 for tumor and 0.00180 mm2/s for normal prostate peripheral region tissue). Image SNR was varied from 2 to 100 and b-values were varied from 0 to 2000s/mm2. The results show that the percentage accuracy and percentage precision were minimized with image SNR. To increase SNR, 10 signal-averagings (NEX) were used considering the limitation in total scan time. The optimal NEX combination for tumor and normal tissue for prostate

  5. Evaluation of diffusion coefficients from composition profiles - the influence of trapping

    DEFF Research Database (Denmark)

    Christiansen, Thomas; Somers, Marcel A. J.

    2006-01-01

    The applicability of the Boltzmann-Matano method for evaluation of a diffusion coefficient and its concentration dependency by line profile analysis is tested on three different (model) systems. All systems involve interstitial diffusion. It is shown that the occurrence of trapping corrupts...... the applicability of the Boltzmann-Matano method....

  6. Value of apparent diffusion coefficients in patients with brain tumors

    International Nuclear Information System (INIS)

    De Luca, Silvina; Stoisa, Daniela; Mondello, Eduardo; Vietti, Julio; Casas, Gabriel; Florenzano, Nestor; Eyheremendy, Eduardo; Martinez Boero, Macarena

    2004-01-01

    Purpose: To determine the utility of ADC values for the diagnosis of encephalic tumors. Material and method: Forty patients with encephalic tumors histopathologically confirmed, have been studied by conventional MR, diffusion and ADC maps. The intensities were measured in the solid tumor portion and the normal white matter, ratios were obtained and correlated in 13 patients with their respective cellularity indexes. Results: Seventeen were glial tumors, with lower ADC values in cases of greater malignancy. In 12 patients the diagnosis was secondary lesions in which the lowest ADC values were obtained. This feature was shared by the epidermoid cyst. The hamartomas, neurinomas, oligodendrogliomas and ependymomas have shown intermediate ADC values. Conclusion: The ADC map is a complement of conventional MR which provides additional information for the diagnosis of encephalic tumors. Low ADC values correlated with high grade malignant tumors. (author)

  7. Modeling diffusion coefficients in binary mixtures of polar and non-polar compounds

    DEFF Research Database (Denmark)

    Medvedev, Oleg; Shapiro, Alexander

    2005-01-01

    The theory of transport coefficients in liquids, developed previously, is tested on a description of the diffusion coefficients in binary polar/non-polar mixtures, by applying advanced thermodynamic models. Comparison to a large set of experimental data shows good performance of the model. Only f...

  8. A nodal method applied to a diffusion problem with generalized coefficients

    International Nuclear Information System (INIS)

    Laazizi, A.; Guessous, N.

    1999-01-01

    In this paper, we consider second order neutrons diffusion problem with coefficients in L ∞ (Ω). Nodal method of the lowest order is applied to approximate the problem's solution. The approximation uses special basis functions in which the coefficients appear. The rate of convergence obtained is O(h 2 ) in L 2 (Ω), with a free rectangular triangulation. (authors)

  9. Diffusion-weighted MRI characteristics of the cerebral metastasis to brain boundary predicts patient outcomes

    International Nuclear Information System (INIS)

    Zakaria, Rasheed; Das, Kumar; Radon, Mark; Bhojak, Maneesh; Rudland, Philip R; Sluming, Vanessa; Jenkinson, Michael D

    2014-01-01

    Diffusion-weighted MRI (DWI) has been used in neurosurgical practice mainly to distinguish cerebral metastases from abscess and glioma. There is evidence from other solid organ cancers and metastases that DWI may be used as a biomarker of prognosis and treatment response. We therefore investigated DWI characteristics of cerebral metastases and their peritumoral region recorded pre-operatively and related these to patient outcomes. Retrospective analysis of 76 cases operated upon at a single institution with DWI performed pre-operatively at 1.5T. Maps of apparent diffusion coefficient (ADC) were generated using standard protocols. Readings were taken from the tumor, peritumoral region and across the brain-tumor interface. Patient outcomes were overall survival and time to local recurrence. A minimum ADC greater than 919.4 × 10 -6 mm 2 /s within a metastasis predicted longer overall survival regardless of adjuvant therapies. This was not simply due to differences between the types of primary cancer because the effect was observed even in a subgroup of 36 patients with the same primary, non-small cell lung cancer. The change in diffusion across the tumor border and into peritumoral brain was measured by the “ADC transition coefficient” or ATC and this was more strongly predictive than ADC readings alone. Metastases with a sharp change in diffusion across their border (ATC >0.279) showed shorter overall survival compared to those with a more diffuse edge. The ATC was the only imaging measurement which independently predicted overall survival in multivariate analysis (hazard ratio 0.54, 95% CI 0.3 – 0.97, p = 0.04). DWI demonstrates changes in the tumor, across the tumor edge and in the peritumoral region which may not be visible on conventional MRI and this may be useful in predicting patient outcomes for operated cerebral metastases

  10. Diffusion MRI for rectal cancer staging: ADC measurements before and after ultrasonographic gel lumen distension

    Energy Technology Data Exchange (ETDEWEB)

    Palmucci, S., E-mail: spalmucci@sirm.org; Piccoli, M.; Piana, S.; Foti, P.V.; Siverino, R.O.A.; Mauro, L.A.; Milone, P.; Ettorre, G.C.

    2017-01-15

    Objectives: To compare Apparent Diffusion Coefficient (ADC) measurements in rectal neoplastic lesions before and after lumen distension obtained with sonography transmission gel. Methods: From January 2014 to July 2016, 25 patients (average age 63.7, range 41–85, 18 males) were studied for pre-treatment rectal cancer staging using a 1.5 T MRI. Diffusion MRI was obtained using echo-planar imaging with b = 800 value; all patients were studied acquiring diffusion sequences with and without rectal lumen distension obtained using sonography transmission gel. In both diffusion sequences, two blinded readers calculated border ADC values and small ADC values, drawing regions of interest respectively along tumour borders and far from tumour borders. Mean ADC values among readers − for each type of ADC measurement − were compared using Wilcoxon matched pairs signed rank test. Correlation was assessed using Pearson analysis. Results: Border ADC mean value for diffusion MR sequences without endorectal contrast was 1.122 mm{sup 2}/sec, with 95% Confidence Interval (CI) = 1.02–1.22; using gel lumen distension, higher border ADC mean value of 1.269 mm{sup 2}/s (95% CI = 1.16–1.38) was obtained. Wilcoxon matched pairs signed rank test revealed statistical difference (p < 0.01); a strong Pearson correlation was reported, with r value of 0.69. Small-ADC mean value was 1.038 mm{sup 2}/s (95% CI = 0.91–1.16) for diffusion sequences acquired without endorectal distension and 1.127 mm{sup 2}/s (95% CI = 0.98–1.27) for diffusion sequences obtained after endorectal gel lumen distension. Wilcoxon analysis did not show statistical difference (p = 0.13). A very strong positive correlation was observed, with r value of 0.81. Conclusions: ADC measurements are slightly higher using endorectal sonographic transmission gel; ROI should be traced far from tumour borders, to minimize gel filled-pixel along the interface between lumen and lesion. Further studies are needed to

  11. Diffusion MRI for rectal cancer staging: ADC measurements before and after ultrasonographic gel lumen distension

    International Nuclear Information System (INIS)

    Palmucci, S.; Piccoli, M.; Piana, S.; Foti, P.V.; Siverino, R.O.A.; Mauro, L.A.; Milone, P.; Ettorre, G.C.

    2017-01-01

    Objectives: To compare Apparent Diffusion Coefficient (ADC) measurements in rectal neoplastic lesions before and after lumen distension obtained with sonography transmission gel. Methods: From January 2014 to July 2016, 25 patients (average age 63.7, range 41–85, 18 males) were studied for pre-treatment rectal cancer staging using a 1.5 T MRI. Diffusion MRI was obtained using echo-planar imaging with b = 800 value; all patients were studied acquiring diffusion sequences with and without rectal lumen distension obtained using sonography transmission gel. In both diffusion sequences, two blinded readers calculated border ADC values and small ADC values, drawing regions of interest respectively along tumour borders and far from tumour borders. Mean ADC values among readers − for each type of ADC measurement − were compared using Wilcoxon matched pairs signed rank test. Correlation was assessed using Pearson analysis. Results: Border ADC mean value for diffusion MR sequences without endorectal contrast was 1.122 mm 2 /sec, with 95% Confidence Interval (CI) = 1.02–1.22; using gel lumen distension, higher border ADC mean value of 1.269 mm 2 /s (95% CI = 1.16–1.38) was obtained. Wilcoxon matched pairs signed rank test revealed statistical difference (p < 0.01); a strong Pearson correlation was reported, with r value of 0.69. Small-ADC mean value was 1.038 mm 2 /s (95% CI = 0.91–1.16) for diffusion sequences acquired without endorectal distension and 1.127 mm 2 /s (95% CI = 0.98–1.27) for diffusion sequences obtained after endorectal gel lumen distension. Wilcoxon analysis did not show statistical difference (p = 0.13). A very strong positive correlation was observed, with r value of 0.81. Conclusions: ADC measurements are slightly higher using endorectal sonographic transmission gel; ROI should be traced far from tumour borders, to minimize gel filled-pixel along the interface between lumen and lesion. Further studies are needed to investigate better

  12. Nonrigid Registration of Prostate Diffusion-Weighted MRI

    Directory of Open Access Journals (Sweden)

    Lei Hao

    2017-01-01

    Full Text Available Motion and deformation are common in prostate diffusion-weighted magnetic resonance imaging (DWI during acquisition. These misalignments lead to errors in estimating an apparent diffusion coefficient (ADC map fitted with DWI. To address this problem, we propose an image registration algorithm to align the prostate DWI and improve ADC map. First, we apply affine transformation to DWI to correct intraslice motions. Then, nonrigid registration based on free-form deformation (FFD is used to compensate for intraimage deformations. To evaluate the influence of the proposed algorithm on ADC values, we perform statistical experiments in three schemes: no processing of the DWI, with the affine transform approach, and with FFD. The experimental results show that our proposed algorithm can correct the misalignment of prostate DWI and decrease the artifacts of ROI in the ADC maps. These ADC maps thus obtain sharper contours of lesions, which are helpful for improving the diagnosis and clinical staging of prostate cancer.

  13. Computation of diffusion coefficients for waters of Gauthami Godavari estuary using one-dimensional advection-diffusion model

    Digital Repository Service at National Institute of Oceanography (India)

    Jyothi, D.; Murty, T.V.R.; Sarma, V.V.; Rao, D.P.

    conditions. As the pollutant load on the estuary increases, the. water quality may deteriorate rapidly and therefore the scientific interests are centered on the analysis of water quality. The pollutants will be subjected to a number of physical, chemical... study we have applied one-dimensional advection-diffusion model for the waters of Gauthami Godavari estuary to determine the axial diffusion coefficients and thereby to predict the impact assessment. The study area (Fig. 1) is the lower most 32 km...

  14. Diffusion-weighted imaging: Apparent diffusion coefficient histogram analysis for detecting pathologic complete response to chemoradiotherapy in locally advanced rectal cancer.

    Science.gov (United States)

    Choi, Moon Hyung; Oh, Soon Nam; Rha, Sung Eun; Choi, Joon-Il; Lee, Sung Hak; Jang, Hong Seok; Kim, Jun-Gi; Grimm, Robert; Son, Yohan

    2016-07-01

    To investigate the usefulness of apparent diffusion coefficient (ADC) values derived from histogram analysis of the whole rectal cancer as a quantitative parameter to evaluate pathologic complete response (pCR) on preoperative magnetic resonance imaging (MRI). We enrolled a total of 86 consecutive patients who had undergone surgery for rectal cancer after neoadjuvant chemoradiotherapy (CRT) at our institution between July 2012 and November 2014. Two radiologists who were blinded to the final pathological results reviewed post-CRT MRI to evaluate tumor stage. Quantitative image analysis was performed using T2 -weighted and diffusion-weighted images independently by two radiologists using dedicated software that performed histogram analysis to assess the distribution of ADC in the whole tumor. After surgery, 16 patients were confirmed to have achieved pCR (18.6%). All parameters from pre- and post-CRT ADC histogram showed good or excellent agreement between two readers. The minimum, 10th, 25th, 50th, and 75th percentile and mean ADC from post-CRT ADC histogram were significantly higher in the pCR group than in the non-pCR group for both readers. The 25th percentile value from ADC histogram in post-CRT MRI had the best diagnostic performance for detecting pCR, with an area under the receiver operating characteristic curve of 0.796. Low percentile values derived from the ADC histogram analysis of rectal cancer on MRI after CRT showed a significant difference between pCR and non-pCR groups, demonstrating the utility of the ADC value as a quantitative and objective marker to evaluate complete pathologic response to preoperative CRT in rectal cancer. J. Magn. Reson. Imaging 2016;44:212-220. © 2015 Wiley Periodicals, Inc.

  15. Determination of the diffusion coefficient of ionic species in Boom Clay by electromigration. First evaluation

    International Nuclear Information System (INIS)

    Maes, N.; Moors, H.; De Canniere, P.; Aertsens, M.; Put, M.

    1997-03-01

    Classical diffusion experiments for strongly retarded radionuclides take a very long time. The migration can be accelerated considerably by applying an electrical field across a saturated porous medium (electromigration). Under the influence of the electric field, the ions will attain a constant velocity which is related to the diffusion coefficient by the law of Einstein (V=zeED/KT). The displacement of the concentration profile is a direct measure for the diffusion coefficient. A description of the problems of pH-disturbances, electro-osmosis and dispersion is given and an the feasibility of the electromigration method is evaluated

  16. Computational error estimates for Monte Carlo finite element approximation with log normal diffusion coefficients

    KAUST Repository

    Sandberg, Mattias

    2015-01-07

    The Monte Carlo (and Multi-level Monte Carlo) finite element method can be used to approximate observables of solutions to diffusion equations with log normal distributed diffusion coefficients, e.g. modelling ground water flow. Typical models use log normal diffusion coefficients with H¨older regularity of order up to 1/2 a.s. This low regularity implies that the high frequency finite element approximation error (i.e. the error from frequencies larger than the mesh frequency) is not negligible and can be larger than the computable low frequency error. This talk will address how the total error can be estimated by the computable error.

  17. Computable error estimates for Monte Carlo finite element approximation of elliptic PDE with lognormal diffusion coefficients

    KAUST Repository

    Hall, Eric

    2016-01-09

    The Monte Carlo (and Multi-level Monte Carlo) finite element method can be used to approximate observables of solutions to diffusion equations with lognormal distributed diffusion coefficients, e.g. modeling ground water flow. Typical models use lognormal diffusion coefficients with H´ older regularity of order up to 1/2 a.s. This low regularity implies that the high frequency finite element approximation error (i.e. the error from frequencies larger than the mesh frequency) is not negligible and can be larger than the computable low frequency error. We address how the total error can be estimated by the computable error.

  18. FORTRAN program for calculating liquid-phase and gas-phase thermal diffusion column coefficients

    International Nuclear Information System (INIS)

    Rutherford, W.M.

    1980-01-01

    A computer program (COLCO) was developed for calculating thermal diffusion column coefficients from theory. The program, which is written in FORTRAN IV, can be used for both liquid-phase and gas-phase thermal diffusion columns. Column coefficients for the gas phase can be based on gas properties calculated from kinetic theory using tables of omega integrals or on tables of compiled physical properties as functions of temperature. Column coefficients for the liquid phase can be based on compiled physical property tables. Program listings, test data, sample output, and users manual are supplied for appendices

  19. Procedures and apparatus for measuring diffusion and distribution coefficients in compacted clays

    Energy Technology Data Exchange (ETDEWEB)

    Hume, H B

    1993-12-01

    Diffusion and distribution coefficients are needed to assess the migration of radionuclides through the compacted clay-based buffer and backfill materials proposed for use in a nuclear fuel waste disposal vault. This report describes the techniques used to measure these coefficients. Both steady-state and transient diffusion experiments are discussed. The procedures used to prepare the clay plug, assemble the cell, conduct the experiment and calculate the results are described. In addition, methods for obtaining distribution coefficients for radionuclides on both loose and compacted clays are discussed. (author). 18 refs., 3 tabs., 16 figs.

  20. Diffusion and solubility coefficients determined by permeation and immersion experiments for organic solvents in HDPE geomembrane.

    Science.gov (United States)

    Chao, Keh-Ping; Wang, Ping; Wang, Ya-Ting

    2007-04-02

    The chemical resistance of eight organic solvents in high density polyethylene (HDPE) geomembrane has been investigated using the ASTM F739 permeation method and the immersion test at different temperatures. The diffusion of the experimental organic solvents in HDPE geomembrane was non-Fickian kinetic, and the solubility coefficients can be consistent with the solubility parameter theory. The diffusion coefficients and solubility coefficients determined by the ASTM F739 method were significantly correlated to the immersion tests (pHDPE as barriers in the field.

  1. Procedures and apparatus for measuring diffusion and distribution coefficients in compacted clays

    International Nuclear Information System (INIS)

    Hume, H.B.

    1993-12-01

    Diffusion and distribution coefficients are needed to assess the migration of radionuclides through the compacted clay-based buffer and backfill materials proposed for use in a nuclear fuel waste disposal vault. This report describes the techniques used to measure these coefficients. Both steady-state and transient diffusion experiments are discussed. The procedures used to prepare the clay plug, assemble the cell, conduct the experiment and calculate the results are described. In addition, methods for obtaining distribution coefficients for radionuclides on both loose and compacted clays are discussed. (author). 18 refs., 3 tabs., 16 figs

  2. Linear Invariant Tensor Interpolation Applied to Cardiac Diffusion Tensor MRI

    Science.gov (United States)

    Gahm, Jin Kyu; Wisniewski, Nicholas; Kindlmann, Gordon; Kung, Geoffrey L.; Klug, William S.; Garfinkel, Alan; Ennis, Daniel B.

    2015-01-01

    Purpose Various methods exist for interpolating diffusion tensor fields, but none of them linearly interpolate tensor shape attributes. Linear interpolation is expected not to introduce spurious changes in tensor shape. Methods Herein we define a new linear invariant (LI) tensor interpolation method that linearly interpolates components of tensor shape (tensor invariants) and recapitulates the interpolated tensor from the linearly interpolated tensor invariants and the eigenvectors of a linearly interpolated tensor. The LI tensor interpolation method is compared to the Euclidean (EU), affine-invariant Riemannian (AI), log-Euclidean (LE) and geodesic-loxodrome (GL) interpolation methods using both a synthetic tensor field and three experimentally measured cardiac DT-MRI datasets. Results EU, AI, and LE introduce significant microstructural bias, which can be avoided through the use of GL or LI. Conclusion GL introduces the least microstructural bias, but LI tensor interpolation performs very similarly and at substantially reduced computational cost. PMID:23286085

  3. Pancreatic cancer: Lack of association between apparent diffusion coefficient values and adverse pathological features

    International Nuclear Information System (INIS)

    Rosenkrantz, A.B.; Matza, B.W.; Sabach, A.; Hajdu, C.H.; Hindman, N.

    2013-01-01

    Aim: To identify retrospectively potential associations between apparent diffusion coefficient (ADC) values of pancreatic adenocarcinoma and tumour grade as well as other pathological features, using histopathological assessment from the Whipple procedure as the reference standard. Materials and methods: Thirty patients with pancreatic adenocarcinoma underwent magnetic resonance imaging (MRI) including diffusion-weighted imaging with b-values of 0 and 500 s/mm 2 before the Whipple procedure. Two radiologists independently recorded the ADC values of the tumour and benign pancreas for all cases. ADC values were compared with histopathological findings following the Whipple procedure. Results: The intra-class correlation coefficient was 0.689 for benign pancreas and 0.695 for tumours, indicating good inter-reader agreement for ADC values. The mean ADC value was significantly lower in tumours than in benign pancreas for both readers (reader 1: 1.74 ± 0.34 × 10 −3 mm 2 /s versus 2.08 ± 0.48 × 10 −3 mm 2 /s, respectively, p = 0.006; reader 2: 1.69 ± 0.41 × 10 −3 mm 2 /s versus 2.11 ± 0.54 × 10 −3 mm 2 /s, respectively, p −3 mm 2 /s versus 1.78 ± 0.33 × 10 −3 mm 2 /s, respectively, p = 0.491; reader 2: 1.62 ± 0.33 × 10 −3 mm 2 /s versus 1.75 ± 0.49 × 10 −3 mm 2 /s, respectively, p = 0.405). The area under the curve (AUC) for differentiation of poorly and well/moderately differentiated tumours was 0.611 and 0.596 for readers 1 and 2, respectively, and was not significantly better than an AUC of 0.500 for either reader (p ≥ 0.306). In addition, ADC was not significantly different for either reader between tumours with stage T3 versus stage T1/T2, between tumours with and without metastatic peri-pancreatic lymph nodes, or between tumours located in the pancreatic head versus other pancreatic regions (p ≥ 0.413). Conclusion: No associations between ADC values of pancreatic adenocarcinoma and tumour grade or other adverse pathological features

  4. Survey on visualization and analysis techniques based on diffusion MRI for in-vivo anisotropic diffusion structures

    International Nuclear Information System (INIS)

    Masutani, Yoshitaka; Sato, Tetsuo; Urayama, Shin-ichi; Bihan, D.L.

    2008-01-01

    In association with development of diffusion MR imaging technologies for anisotropic diffusion measurement in living body, related research is explosively increasing including research fields of applied mathematics and visualization in addition to MR imaging, biomedical image technology, and medical science. One of the reasons is that the diffusion MRI data set is a set of high dimensional image information beyond conventional scalar or vector images, and is attractive for the researchers in the related fields. This survey paper is mainly aimed at introducing state-of-the-art of post processing techniques reported in the literature for diffusion MRI data, such as analysis and visualization. (author)

  5. Study on diffusion anisotropy of cerebral ischemia using diffusion weighted echo-planar MRI

    International Nuclear Information System (INIS)

    Kajima, Toshio

    1997-01-01

    Focal cerebral ischemia was produced by occlusion of the intracranial main cerebral artery with a silicone cylinder in Wistar rats. Diffusion-weighted echo-planar images (DW-EPls) using the motion-probing gradient (MPG) method were acquired at 1-3 hours and 24-48 hours after occlusion. Apparent diffusion coefficients (ADCs) were calculated from these images in ischemic lesions and in normal unoccluded regions. Results were as follows. Ischemic lesions could be detected on the DW-EPIs at 1 hour after occlusion. The ADC of water in the brain tissue was smaller than that of free water as a result of restricted diffusion. Anisotropic diffusion that probably can be attributed to the myelin sheath was observed in the normal white matter. In the ischemic lesions, the ADC decreased rapidly within 1-3 hours after occlusion and then decreased gradually after 24-48 hours. In the ischemic white matter, diffusion anisotropy disappeared at 24-48 hours after occlusion. Diffusion-weighted imaging may have applications in the examination of pathophysiological mechanisms in cerebral ischemia by means of evaluation of ADC and diffusion anisotropy. (author)

  6. Dense fluid self-diffusion coefficient calculations using perturbation theory and molecular dynamics

    Directory of Open Access Journals (Sweden)

    COELHO L. A. F.

    1999-01-01

    Full Text Available A procedure to correlate self-diffusion coefficients in dense fluids by using the perturbation theory (WCA coupled with the smooth-hard-sphere theory is presented and tested against molecular simulations and experimental data. This simple algebraic expression correlates well the self-diffusion coefficients of carbon dioxide, ethane, propane, ethylene, and sulfur hexafluoride. We have also performed canonical ensemble molecular dynamics simulations by using the Hoover-Nosé thermostat and the mean-square displacement formula to compute self-diffusion coefficients for the reference WCA intermolecular potential. The good agreement obtained from both methods, when compared with experimental data, suggests that the smooth-effective-sphere theory is a useful procedure to correlate diffusivity of pure substances.

  7. The surface diffusion coefficient for an arbitrarily curved fluid-fluid interface. (I). General expression

    Science.gov (United States)

    M. C. Sagis, Leonard

    2001-03-01

    In this paper, we develop a theory for the calculation of the surface diffusion coefficient for an arbitrarily curved fluid-fluid interface. The theory is valid for systems in hydrodynamic equilibrium, with zero mass-averaged velocities in the bulk and interfacial regions. We restrict our attention to systems with isotropic bulk phases, and an interfacial region that is isotropic in the plane parallel to the dividing surface. The dividing surface is assumed to be a simple interface, without memory effects or yield stresses. We derive an expression for the surface diffusion coefficient in terms of two parameters of the interfacial region: the coefficient for plane-parallel diffusion D (AB)aa(ξ) , and the driving force d(B)I||(ξ) . This driving force is the parallel component of the driving force for diffusion in the interfacial region. We derive an expression for this driving force using the entropy balance.

  8. ADC histogram analysis for adrenal tumor histogram analysis of apparent diffusion coefficient in differentiating adrenal adenoma from pheochromocytoma.

    Science.gov (United States)

    Umanodan, Tomokazu; Fukukura, Yoshihiko; Kumagae, Yuichi; Shindo, Toshikazu; Nakajo, Masatoyo; Takumi, Koji; Nakajo, Masanori; Hakamada, Hiroto; Umanodan, Aya; Yoshiura, Takashi

    2017-04-01

    To determine the diagnostic performance of apparent diffusion coefficient (ADC) histogram analysis in diffusion-weighted (DW) magnetic resonance imaging (MRI) for differentiating adrenal adenoma from pheochromocytoma. We retrospectively evaluated 52 adrenal tumors (39 adenomas and 13 pheochromocytomas) in 47 patients (21 men, 26 women; mean age, 59.3 years; range, 16-86 years) who underwent DW 3.0T MRI. Histogram parameters of ADC (b-values of 0 and 200 [ADC 200 ], 0 and 400 [ADC 400 ], and 0 and 800 s/mm 2 [ADC 800 ])-mean, variance, coefficient of variation (CV), kurtosis, skewness, and entropy-were compared between adrenal adenomas and pheochromocytomas, using the Mann-Whitney U-test. Receiver operating characteristic (ROC) curves for the histogram parameters were generated to differentiate adrenal adenomas from pheochromocytomas. Sensitivity and specificity were calculated by using a threshold criterion that would maximize the average of sensitivity and specificity. Variance and CV of ADC 800 were significantly higher in pheochromocytomas than in adrenal adenomas (P histogram parameters for diagnosing adrenal adenomas (ADC 200 , 0.82; ADC 400 , 0.87; and ADC 800 , 0.92), with sensitivity of 84.6% and specificity of 84.6% (cutoff, ≤2.82) with ADC 200 ; sensitivity of 89.7% and specificity of 84.6% (cutoff, ≤2.77) with ADC 400 ; and sensitivity of 94.9% and specificity of 92.3% (cutoff, ≤2.67) with ADC 800 . ADC histogram analysis of DW MRI can help differentiate adrenal adenoma from pheochromocytoma. 3 J. Magn. Reson. Imaging 2017;45:1195-1203. © 2016 International Society for Magnetic Resonance in Medicine.

  9. Assessment of renal fibrosis in chronic kidney disease using diffusion-weighted MRI

    International Nuclear Information System (INIS)

    Zhao, J.; Wang, Z.J.; Liu, M.; Zhu, J.; Zhang, X.; Zhang, T.; Li, S.; Li, Y.

    2014-01-01

    Aim: To assess the performance of diffusion-weighted magnetic resonance imaging (MRI) for the assessment of renal fibrosis in chronic kidney disease (CKD), with histopathology as a reference standard. Materials and methods: Forty patients with CKD and 30 healthy volunteers were recruited for the study. All participants underwent diffusion-weighted MRI. Renal biopsy was performed in 25 patients with CKD. Mean renal medullary and cortical apparent diffusion coefficient (ADC) values were compared between CKD patients and the healthy volunteers. Pearson's correlation coefficient was calculated to investigate the relationship between ADC values, serum creatinine (SCr), estimated glomerular filtration rate (eGFR), 24 h urinary protein (24h-UPRO), and renal histopathological scores. Results: Cortical and medullary ADC values in the CKD group were significantly lower compared to those in the healthy controls. In the CKD group, a significant negative correlation was found between cortical ADC values and SCr/24h-UPRO, and significant positive correlation was found between cortical ADC and eGFR. There was also a significant negative correlation between medullary ADC values and SCr. Both cortical and medullary ADC values were significantly correlated with histopathological fibrosis score. Conclusion: Renal ADC values strongly correlate with histological measures of fibrosis, and have the potential to enhance the non-invasive monitoring of chronic kidney disease. - Highlights: • Renal ADC values in the CKD patients were lower than those in controls. • Renal ADC values were strongly correlated with histological fibrosis score. • Renal ADC values have the potential to enhance the noninvasive monitoring of CKD

  10. A new consistent definition of the homogenized diffusion coefficient of a lattice, limitations of the homogenization concept, and discussion of previously defined coefficients

    International Nuclear Information System (INIS)

    Deniz, V.C.

    1980-01-01

    The problem concerned with the correct definition of the homogenized diffusion coefficient of a lattice, and the concurrent problem of whether or not a homogenized diffusion equation can be formally set up, is studied by a space-energy-angle dependent treatment for a general lattice cell using an operator notation which applies to any eigen-problem. A new definition of the diffusion coefficient is given, which combines within itself the individual merits of the two definitions of Benoist. The relation between the new coefficient and the ''uncorrected'' Benoist coefficient is discussed by considering continuous-spectrum and multi-group diffusion equations. Other definitions existing in the literature are briefly discussed. It is concluded that a diffusion coefficient should represent only leakage effects. A comparison is made between the homogenization approach and the approach via eigen-coefficients, and brief indications are given of a possible scheme for the latter. (author)

  11. Research and development of groundwater dating (Part 3). A proposal of determination method for diffusion coefficients of dissolved helium in rock and applicability of estimation of diffusion coefficients using anions

    International Nuclear Information System (INIS)

    Higashihara, Tomohiro; Nakata, Kotaro; Hasegawa, Takuma

    2006-01-01

    Dissolved helium in groundwater is one of the most suitable tracers for the groundwater dating. The diffusion coefficients in aquitard and aquifer were important to estimate an accumulation of the helium in groundwater. However, few papers have been reported about the diffusion of helium in rocks. In this study, effective diffusion coefficients of the helium in sandstones and mudstone were determined using a through-diffusion method. The effective diffusion coefficients of helium were in the range of 1.5 x 10 -10 to 1.1 x 10 -9 m 2 s -1 and larger than those of Br - ions. Geometrical factors for the diffusion of helium were also larger than those for the diffusion of Br - ions. This fact suggests that diffusion path of helium in the rocks is not more restricted than that of Br - ions. The diffusion coefficients of helium were also estimated using the diffusion coefficient of helium in bulk water and formation factors for diffusion of Br - ions. The estimated diffusion coefficients of helium were larger than the effective diffusion coefficients. It is clarified that the effective diffusion coefficients of helium are underestimated by the estimation method using anions. (author)

  12. A new consistent definition of the homogenized diffusion coefficient of a lattice, limitations of the homogenization concept, and discussion of previously defined coefficients

    International Nuclear Information System (INIS)

    Deniz, V.C.

    1978-01-01

    The problem concerned with the correct definition of the homogenized diffusion coefficient of a lattice, and the concurrent problem of whether or not a homogenized diffusion equation can be formally set up, is studied by a space-energy angle dependent treatment for a general lattice cell; using an operator notation which applies to any eigen-problem. It is shown that the diffusion coefficient should represent only leakage effects. A new definition of the diffusion coefficient is given, which combines within itself the individual merits of each of the two definitions of Benoist, and reduces to the 'uncorrected' Benoist coefficient in certain cases. The conditions under which a homogenized diffusion equation can be obtained are discussed. A compatison is made between the approach via a diffusion equation and the approach via the eigen-coefficients of Deniz. Previously defined diffusion coefficients are discussed, and it is shown that the transformed eigen-coefficients proposed by Gelbard and by Larsen are unsuitable as diffusion coefficients, and that the cell-edge normalization of the Bonalumi coefficient is not physically justifiable. (author)

  13. Eddy diffusion coefficients and their upper limits based on application of the similarity theory

    Directory of Open Access Journals (Sweden)

    M. N. Vlasov

    2015-07-01

    Full Text Available The equation for the diffusion velocity in the mesosphere and the lower thermosphere (MLT includes the terms for molecular and eddy diffusion. These terms are very similar. For the first time, we show that, by using the similarity theory, the same formula can be obtained for the eddy diffusion coefficient as the commonly used formula derived by Weinstock (1981. The latter was obtained by taking, as a basis, the integral function for diffusion derived by Taylor (1921 and the three-dimensional Kolmogorov kinetic energy spectrum. The exact identity of both formulas means that the eddy diffusion and heat transport coefficients used in the equations, both for diffusion and thermal conductivity, must meet a criterion that restricts the outer eddy scale to being much less than the scale height of the atmosphere. This requirement is the same as the requirement that the free path of molecules must be much smaller than the scale height of the atmosphere. A further result of this criterion is that the eddy diffusion coefficients Ked, inferred from measurements of energy dissipation rates, cannot exceed the maximum value of 3.2 × 106 cm2 s−1 for the maximum value of the energy dissipation rate of 2 W kg−1 measured in the mesosphere and the lower thermosphere (MLT. This means that eddy diffusion coefficients larger than the maximum value correspond to eddies with outer scales so large that it is impossible to use these coefficients in eddy diffusion and eddy heat transport equations. The application of this criterion to the different experimental data shows that some reported eddy diffusion coefficients do not meet this criterion. For example, the large values of these coefficients (1 × 107 cm2 s−1 estimated in the Turbulent Oxygen Mixing Experiment (TOMEX do not correspond to this criterion. The Ked values inferred at high latitudes by Lübken (1997 meet this criterion for summer and winter polar data, but the Ked values for summer at low latitudes

  14. A numerical study of one-dimensional replicating patterns in reaction-diffusion systems with non-linear diffusion coefficients

    International Nuclear Information System (INIS)

    Ferreri, J. C.; Carmen, A. del

    1998-01-01

    A numerical study of the dynamics of pattern evolution in reaction-diffusion systems is performed, although limited to one spatial dimension. The diffusion coefficients are nonlinear, based on powers of the scalar variables. The system keeps the dynamics of previous studies in the literature, but the presence of nonlinear diffusion generates a field of strong nonlinear interactions due to the presence of receding travelling waves. This field is limited by the plane of symmetry of the space domain and the last born outgoing travelling wave. These effects are discussed. (author). 10 refs., 7 figs

  15. Radon diffusion coefficients for soils. Previous studies and their application to uranium-bearing wastes

    International Nuclear Information System (INIS)

    Sasaki, Tomozo; Gunji, Yasuyoshi; Iida, Takao

    2008-01-01

    Radon diffusion in soils has been studied over the years by many researchers. The application of such studies to the evaluation of radiation exposure caused by radon from uranium-bearing wastes disposed in a shallow land site is very important. The present paper surveyed closely relevant studies and elucidated the inherent nature of radon diffusion in terms of the definition of radon diffusion coefficients. Then, basic features of measurement methods for determining radon diffusion coefficients in soils were explained. Furthermore, theoretical aspects of radon diffusion in soils were discussed in terms of microscopic radon diffusion in soils and large-scale radon diffusion through cover soil defects for uranium mill tailings. Finally, in order to apply the radon diffusion studies to uranium-bearing waste disposal in shallow land sites, new challenges were presented: elucidation of radon diffusion in uranium-bearing wastes and cover-soil cracks, and demonstration of the validity of applying only radon diffusion in the evaluation of radiation exposure caused by radon, which would come through Japanese cover soils for uranium-bearing waste disposal. (author)

  16. Using the apparent diffusion coefficient to identifying MGMT promoter methylation status early in glioblastoma: importance of analytical method

    Energy Technology Data Exchange (ETDEWEB)

    Rundle-Thiele, Dayle [Centre for Clinical Research, University of Queensland, Brisbane, Queensland (Australia); Day, Bryan; Stringer, Brett [Brain Cancer Research Unit, Queensland Institute of Medical Research, Brisbane, Queensland (Australia); Fay, Michael [Department of Radiation Oncology, Royal Brisbane and Women' s Hospital, Brisbane, Queensland (Australia); Martin, Jennifer [Discipline of Clinical Pharmacology, School of Medicine and Public Health, University of Newcastle, Newcastle, New South Wales (Australia); Jeffree, Rosalind L [Department of Neurosurgery, Royal Brisbane and Women' s Hospital, Brisbane, Queensland (Australia); Thomas, Paul [Queensland PET Service, Royal Brisbane and Women' s Hospital, Brisbane, Queensland (Australia); Bell, Christopher [Centre for Clinical Research, University of Queensland, Brisbane, Queensland (Australia); Salvado, Olivier [CSIRO Digital Productivity Flagship, CSIRO, Herston, Queensland (Australia); Gal, Yaniv [Centre for Medical Diagnostic Technologies in Queensland, University of Queensland, Brisbane, Queensland (Australia); Coulthard, Alan [Discipline of Medical Imaging, University of Queensland, St Lucia, Queensland (Australia); Department of Medical Imaging, Royal Brisbane and Women' s Hospital, Brisbane, Queensland (Australia); Crozier, Stuart [Centre for Medical Diagnostic Technologies in Queensland, University of Queensland, Brisbane, Queensland (Australia); Rose, Stephen, E-mail: stephen.rose@csiro.au [CSIRO Digital Productivity Flagship, CSIRO, Herston, Queensland (Australia); Centre for Clinical Research, University of Queensland, Brisbane, Queensland (Australia)

    2015-06-15

    Accurate knowledge of O{sup 6}-methylguanine methyltransferase (MGMT) gene promoter subtype in patients with glioblastoma (GBM) is important for treatment. However, this test is not always available. Pre-operative diffusion MRI (dMRI) can be used to probe tumour biology using the apparent diffusion coefficient (ADC); however, its ability to act as a surrogate to predict MGMT status has shown mixed results. We investigated whether this was due to variations in the method used to analyse ADC. We undertook a retrospective study of 32 patients with GBM who had MGMT status measured. Matching pre-operative MRI data were used to calculate the ADC within contrast enhancing regions of tumour. The relationship between ADC and MGMT was examined using two published ADC methods. A strong trend between a measure of ‘minimum ADC’ and methylation status was seen. An elevated minimum ADC was more likely in the methylated compared to the unmethylated MGMT group (U = 56, P = 0.0561). In contrast, utilising a two-mixture model histogram approach, a significant reduction in mean measure of the ‘low ADC’ component within the histogram was associated with an MGMT promoter methylation subtype (P < 0.0246). This study shows that within the same patient cohort, the method selected to analyse ADC measures has a significant bearing on the use of that metric as a surrogate marker of MGMT status. Thus for dMRI data to be clinically useful, consistent methods of data analysis need to be established prior to establishing any relationship with genetic or epigenetic profiling.

  17. Using the apparent diffusion coefficient to identifying MGMT promoter methylation status early in glioblastoma: importance of analytical method

    International Nuclear Information System (INIS)

    Rundle-Thiele, Dayle; Day, Bryan; Stringer, Brett; Fay, Michael; Martin, Jennifer; Jeffree, Rosalind L; Thomas, Paul; Bell, Christopher; Salvado, Olivier; Gal, Yaniv; Coulthard, Alan; Crozier, Stuart; Rose, Stephen

    2015-01-01

    Accurate knowledge of O 6 -methylguanine methyltransferase (MGMT) gene promoter subtype in patients with glioblastoma (GBM) is important for treatment. However, this test is not always available. Pre-operative diffusion MRI (dMRI) can be used to probe tumour biology using the apparent diffusion coefficient (ADC); however, its ability to act as a surrogate to predict MGMT status has shown mixed results. We investigated whether this was due to variations in the method used to analyse ADC. We undertook a retrospective study of 32 patients with GBM who had MGMT status measured. Matching pre-operative MRI data were used to calculate the ADC within contrast enhancing regions of tumour. The relationship between ADC and MGMT was examined using two published ADC methods. A strong trend between a measure of ‘minimum ADC’ and methylation status was seen. An elevated minimum ADC was more likely in the methylated compared to the unmethylated MGMT group (U = 56, P = 0.0561). In contrast, utilising a two-mixture model histogram approach, a significant reduction in mean measure of the ‘low ADC’ component within the histogram was associated with an MGMT promoter methylation subtype (P < 0.0246). This study shows that within the same patient cohort, the method selected to analyse ADC measures has a significant bearing on the use of that metric as a surrogate marker of MGMT status. Thus for dMRI data to be clinically useful, consistent methods of data analysis need to be established prior to establishing any relationship with genetic or epigenetic profiling

  18. Exciton diffusion coefficient measurement in ZnO nanowires under electron beam irradiation

    Science.gov (United States)

    Donatini, Fabrice; Pernot, Julien

    2018-03-01

    In semiconductor nanowires (NWs) the exciton diffusion coefficient can be determined using a scanning electron microscope fitted with a cathodoluminescence system. High spatial and temporal resolution cathodoluminescence experiments are needed to measure independently the exciton diffusion length and lifetime in single NWs. However, both diffusion length and lifetime can be affected by the electron beam bombardment during observation and measurement. Thus, in this work the exciton lifetime in a ZnO NW is measured versus the electron beam dose (EBD) via a time-resolved cathodoluminescence experiment with a temporal resolution of 50 ps. The behavior of the measured exciton lifetime is consistent with our recent work on the EBD dependence of the exciton diffusion length in similar NWs investigated under comparable SEM conditions. Combining the two results, the exciton diffusion coefficient in ZnO is determined at room temperature and is found constant over the full span of EBD.

  19. Blackness coefficients, effective diffusion parameters, and control rod worths for thermal reactors - Methods

    Energy Technology Data Exchange (ETDEWEB)

    Bretscher, M M [Argonne National Laboratory, Argonne, IL 60439 (United States)

    1985-07-01

    Simple diffusion theory cannot be used to evaluate control rod worths in thermal neutron reactors because of the strongly absorbing character of the control material. However, reliable control rod worths can be obtained within the framework of diffusion theory if the control material is characterized by a set of mesh-dependent effective diffusion parameters. For thin slab absorbers the effective diffusion parameters can be expressed as functions of a suitably-defined pair of 'blackness coefficients'. Methods for calculating these blackness coefficients in the P1, P3, and P5 approximations, with and without scattering, are presented. For control elements whose geometry does not permit a thin slab treatment, other methods are needed for determining the effective diffusion parameters. One such method, based on reaction rate ratios, is discussed. (author)

  20. Albedo-adjusted fast-neutron diffusion coefficients in reactor reflectors

    International Nuclear Information System (INIS)

    Terney, W.B.

    1975-01-01

    In the newer, larger pressurized-water reactor cores, the calculated power distributions are fairly sensitive to the number of neutron groups used and to the treatment of the reflector cross sections. Comparisons between transport and diffusion calculations show that the latter substantially underpredict the reflector albedos in the fast (top) group and that the power distribution is shifted toward the core center when compared to 4-group transport theory results. When the fast-neutron diffusion coefficients are altered to make the transport- and diffusion-theory albedos agree, the power distributions are also brought into agreement. An expression for the fast-neutron diffusion coefficients in reflector regions has been derived such that the diffusion calculation reproduces the albedo obtained from a transport solution. In addition, a correction factor for mesh effects applicable to coarse mesh problems is presented. The use of the formalism gives the correct albedos and improved power distributions. (U.S.)

  1. Rapid yet accurate measurement of mass diffusion coefficients by phase shifting interferometer

    CERN Document Server

    Guo Zhi Xiong; Komiya, A

    1999-01-01

    The technique of using a phase-shifting interferometer is applied to the study of diffusion in transparent liquid mixtures. A quick method is proposed for determining the diffusion coefficient from the measurements of the location of fringes on a grey level picture. The measurement time is very short (within 100 s) and a very small transient diffusion field can be observed and recorded accurately with a rate of 30 frames per second. The measurement can be completed using less than 0.12 cc of solutions. The influence of gravity on the measurement of the diffusion coefficient is eliminated in the present method. Results on NaCl-water diffusion systems are presented and compared with the reference data. (author)

  2. Interaction between lactose and cadmium chloride in aqueous solutions as seen by diffusion coefficients measurements

    International Nuclear Information System (INIS)

    Verissimo, Luis M.P.; Gomes, Joselaine C.S.; Romero, Carmen; Esteso, Miguel A.; Sobral, Abilio J.F.N.; Ribeiro, Ana C.F.

    2013-01-01

    Highlights: ► Diffusion coefficients of aqueous systems containing lactose and cadmium chloride. ► Influence of the lactose on the diffusion of cadmium chloride. ► Interactions between Cd 2+ and lactose. -- Abstract: Diffusion coefficients of an aqueous system containing cadmium chloride 0.100 mol · dm −3 and lactose at different concentrations at 25 °C have been measured, using a conductimetric cell and an automatic apparatus to follow diffusion. The cell relies on an open-ended capillary method and a conductimetric technique is used to follow the diffusion process by measuring the resistance of a solution inside the capillaries, at recorded times. From these results and by ab initio calculations, it was possible to obtain a better understanding of the effect of lactose on transport of cadmium chloride in aqueous solutions

  3. Support vector machine for breast cancer classification using diffusion-weighted MRI histogram features: Preliminary study.

    Science.gov (United States)

    Vidić, Igor; Egnell, Liv; Jerome, Neil P; Teruel, Jose R; Sjøbakk, Torill E; Østlie, Agnes; Fjøsne, Hans E; Bathen, Tone F; Goa, Pål Erik

    2018-05-01

    Diffusion-weighted MRI (DWI) is currently one of the fastest developing MRI-based techniques in oncology. Histogram properties from model fitting of DWI are useful features for differentiation of lesions, and classification can potentially be improved by machine learning. To evaluate classification of malignant and benign tumors and breast cancer subtypes using support vector machine (SVM). Prospective. Fifty-one patients with benign (n = 23) and malignant (n = 28) breast tumors (26 ER+, whereof six were HER2+). Patients were imaged with DW-MRI (3T) using twice refocused spin-echo echo-planar imaging with echo time / repetition time (TR/TE) = 9000/86 msec, 90 × 90 matrix size, 2 × 2 mm in-plane resolution, 2.5 mm slice thickness, and 13 b-values. Apparent diffusion coefficient (ADC), relative enhanced diffusivity (RED), and the intravoxel incoherent motion (IVIM) parameters diffusivity (D), pseudo-diffusivity (D*), and perfusion fraction (f) were calculated. The histogram properties (median, mean, standard deviation, skewness, kurtosis) were used as features in SVM (10-fold cross-validation) for differentiation of lesions and subtyping. Accuracies of the SVM classifications were calculated to find the combination of features with highest prediction accuracy. Mann-Whitney tests were performed for univariate comparisons. For benign versus malignant tumors, univariate analysis found 11 histogram properties to be significant differentiators. Using SVM, the highest accuracy (0.96) was achieved from a single feature (mean of RED), or from three feature combinations of IVIM or ADC. Combining features from all models gave perfect classification. No single feature predicted HER2 status of ER + tumors (univariate or SVM), although high accuracy (0.90) was achieved with SVM combining several features. Importantly, these features had to include higher-order statistics (kurtosis and skewness), indicating the importance to account for heterogeneity. Our

  4. A biomimetic tumor tissue phantom for validating diffusion-weighted MRI measurements.

    Science.gov (United States)

    McHugh, Damien J; Zhou, Feng-Lei; Wimpenny, Ian; Poologasundarampillai, Gowsihan; Naish, Josephine H; Hubbard Cristinacce, Penny L; Parker, Geoffrey J M

    2018-07-01

    To develop a biomimetic tumor tissue phantom which more closely reflects water diffusion in biological tissue than previously used phantoms, and to evaluate the stability of the phantom and its potential as a tool for validating diffusion-weighted (DW) MRI measurements. Coaxial-electrospraying was used to generate micron-sized hollow polymer spheres, which mimic cells. The bulk structure was immersed in water, providing a DW-MRI phantom whose apparent diffusion coefficient (ADC) and microstructural properties were evaluated over a period of 10 months. Independent characterization of the phantom's microstructure was performed using scanning electron microscopy (SEM). The repeatability of the construction process was investigated by generating a second phantom, which underwent high resolution synchrotron-CT as well as SEM and MR scans. ADC values were stable (coefficients of variation (CoVs) < 5%), and varied with diffusion time, with average values of 1.44 ± 0.03 µm 2 /ms (Δ = 12 ms) and 1.20 ± 0.05 µm 2 /ms (Δ = 45 ms). Microstructural parameters showed greater variability (CoVs up to 13%), with evidence of bias in sphere size estimates. Similar trends were observed in the second phantom. A novel biomimetic phantom has been developed and shown to be stable over 10 months. It is envisaged that such phantoms will be used for further investigation of microstructural models relevant to characterizing tumor tissue, and may also find application in evaluating acquisition protocols and comparing DW-MRI-derived biomarkers obtained from different scanners at different sites. Magn Reson Med 80:147-158, 2018. © 2017 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is

  5. Permeability and Diffusion Coefficients of Single Methyl Lactate Enantiomers in Nafion® and Cellophane Membranes Measured in Diffusion Cell.

    Czech Academy of Sciences Publication Activity Database

    Hovorka, Š.; Randová, A.; Borbášová, T.; Sysel, P.; Vychodilová, Hana; Červenková Šťastná, Lucie; Brožová, Libuše; Žitka, Jan; Storch, Jan; Kačírková, Marie; Drašar, P.; Izák, Pavel

    2016-01-01

    Roč. 158, JAN 28 (2016), s. 322-332 ISSN 1383-5866 R&D Projects: GA ČR(CZ) GAP106/12/0569 Institutional support: RVO:67985858 ; RVO:61389013 Keywords : diffusion coefficient measurement * permeability * nafion * cellophane * chirality of polymer membrane Subject RIV: CI - Industrial Chemistry, Chemical Engineering Impact factor: 3.359, year: 2016

  6. Quantitative diffusion characteristics of the human brain depend on MRI sequence parameters

    Energy Technology Data Exchange (ETDEWEB)

    Wilson, M.; Blumhardt, L.D. [University of Nottingham, Department of Neurology, Royal Preston Hospital, Preston (United Kingdom); Morgan, P.S. [Division of Academic Radiology, Queens Medical Centre, Nottingham (United Kingdom)

    2002-07-01

    Quantitative diffusion-weighted MRI has been applied to the study of neurological diseases, including multiple sclerosis, where the molecular self-diffusion coefficient D has been measured in both lesions and normal-appearing white matter. Histograms of D have been used as a novel measure of the ''lesion load'', with potential applications that include the monitoring of efficacy in new treatment trials. However different ways of measuring D may affect its value, making comparison between different centres and research groups impossible. We aimed to assess the effect, if any, of using two different MRI sequences on the value of D. We studied 13 healthy volunteers, using two different quantitative diffusion sequences (including different b{sub max} values and gradient applications). Maps of D were analysed using both regions of interest (ROI) in white matter and ''whole brain'' histograms, and compared between the two sequences. In addition, we studied three standardised test liquids (with known values of D) using both sequences. Histograms from the two sequences had different distributions, with a greater spread and higher peak position from the sequence with lower b{sub max}. This greater spread of D was also evident in the white matter and test liquid ROI. ''Limits of agreement'' analysis demonstrated that the differences could be clinically relevant, despite significant correlations between the sequences obtained using simple rank methods. We conclude that different quantitative diffusion sequences are unlikely to produce directly comparable values of D, particularly if different b{sub max} values are used. In addition, the use of inappropriate statistical tests may give false impressions of close agreement. Standardisation of methods for the measurement of D are required if these techniques are to become useful tools, for example in monitoring changes in the disease burden of multiple sclerosis. (orig.)

  7. Quantitative diffusion characteristics of the human brain depend on MRI sequence parameters

    International Nuclear Information System (INIS)

    Wilson, M.; Blumhardt, L.D.; Morgan, P.S.

    2002-01-01

    Quantitative diffusion-weighted MRI has been applied to the study of neurological diseases, including multiple sclerosis, where the molecular self-diffusion coefficient D has been measured in both lesions and normal-appearing white matter. Histograms of D have been used as a novel measure of the ''lesion load'', with potential applications that include the monitoring of efficacy in new treatment trials. However different ways of measuring D may affect its value, making comparison between different centres and research groups impossible. We aimed to assess the effect, if any, of using two different MRI sequences on the value of D. We studied 13 healthy volunteers, using two different quantitative diffusion sequences (including different b max values and gradient applications). Maps of D were analysed using both regions of interest (ROI) in white matter and ''whole brain'' histograms, and compared between the two sequences. In addition, we studied three standardised test liquids (with known values of D) using both sequences. Histograms from the two sequences had different distributions, with a greater spread and higher peak position from the sequence with lower b max . This greater spread of D was also evident in the white matter and test liquid ROI. ''Limits of agreement'' analysis demonstrated that the differences could be clinically relevant, despite significant correlations between the sequences obtained using simple rank methods. We conclude that different quantitative diffusion sequences are unlikely to produce directly comparable values of D, particularly if different b max values are used. In addition, the use of inappropriate statistical tests may give false impressions of close agreement. Standardisation of methods for the measurement of D are required if these techniques are to become useful tools, for example in monitoring changes in the disease burden of multiple sclerosis. (orig.)

  8. On the Diffusion Coefficient of Two-step Method for LWR analysis

    International Nuclear Information System (INIS)

    Lee, Deokjung; Choi, Sooyoung; Smith, Kord S.

    2015-01-01

    The few-group constants including diffusion coefficients are generated from the assembly calculation results. Once the assembly calculation is done, the cross sections (XSs) are spatially homogenized, and a critical spectrum calculation is performed in order to take into account the neutron leakages of the lattice. The diffusion coefficient is also generated through the critical spectrum calculation. Three different methods of the critical spectrum calculation such as B1 method, P1 method, and fundamental mode (FM) calculation method are considered in this paper. The diffusion coefficients can also be affected by transport approximations for the transport XS calculation which is used in the assembly transport lattice calculation in order to account for the anisotropic scattering effects. The outflow transport approximation and the inflow transport approximation are investigated in this paper. The accuracy of the few group data especially the diffusion coefficients has been studied to optimize the combination of the transport correction methods and the critical spectrum calculation methods using the UNIST lattice physics code STREAM. The combination of the inflow transport approximation and the FM method is shown to provide the highest accuracy in the LWR core calculations. The methodologies to calculate the diffusion coefficients have been reviewed, and the performances of them have been investigated with a LWR core problem. The combination of the inflow transport approximation and the fundamental mode critical spectrum calculation shows the smallest errors in terms of assembly power distribution

  9. Interpretation of diffusion coefficients in nanostructured materials from random walk numerical simulation.

    Science.gov (United States)

    Anta, Juan A; Mora-Seró, Iván; Dittrich, Thomas; Bisquert, Juan

    2008-08-14

    We make use of the numerical simulation random walk (RWNS) method to compute the "jump" diffusion coefficient of electrons in nanostructured materials via mean-square displacement. First, a summary of analytical results is given that relates the diffusion coefficient obtained from RWNS to those in the multiple-trapping (MT) and hopping models. Simulations are performed in a three-dimensional lattice of trap sites with energies distributed according to an exponential distribution and with a step-function distribution centered at the Fermi level. It is observed that once the stationary state is reached, the ensemble of particles follow Fermi-Dirac statistics with a well-defined Fermi level. In this stationary situation the diffusion coefficient obeys the theoretical predictions so that RWNS effectively reproduces the MT model. Mobilities can be also computed when an electrical bias is applied and they are observed to comply with the Einstein relation when compared with steady-state diffusion coefficients. The evolution of the system towards the stationary situation is also studied. When the diffusion coefficients are monitored along simulation time a transition from anomalous to trap-limited transport is observed. The nature of this transition is discussed in terms of the evolution of electron distribution and the Fermi level. All these results will facilitate the use of RW simulation and related methods to interpret steady-state as well as transient experimental techniques.

  10. Mutual diffusion coefficients of isopropanol + n-heptane and isobutanol + n-heptane

    International Nuclear Information System (INIS)

    He, Maogang; Peng, Sanguo; Zhang, Ying; Zhang, Shi; Liu, Xiangyang

    2016-01-01

    Graphical abstract: Mutual diffusion coefficients of isopropanol + n-heptane as a function of mass fraction of isopropanol. - Highlights: • D_1_2 of isopropanol + n-heptane and isobutanol + n-heptane were measured. • Effect of T, w and M of the solute on D_1_2 were analyzed. • A new correlation is proposed for the experimental data. - Abstract: The mutual diffusion coefficients of isopropanol + n-heptane and isobutanol + n-heptane were measured at different concentrations and in the temperature range from (283.15 to 323.15) K. The measurements were carried out using a digital holographic interferometry system. For all the mixtures investigated, the mutual diffusion coefficient increases as the temperature increases. At the same concentration and temperature, the mutual diffusion coefficients of isobutanol + n-heptane were lower than those of isopropanol + n-heptane due to the fact that the molecular weight of isobutanol is larger than that of isopropanol. A new correlation is proposed for the mutual diffusion coefficients of isopropanol + n-heptane and isobutanol + n-heptane. The absolute average relative deviation between the correlation and experiment is less than 1.90%.

  11. Analytical performance bounds for multi-tensor diffusion-MRI.

    Science.gov (United States)

    Ahmed Sid, Farid; Abed-Meraim, Karim; Harba, Rachid; Oulebsir-Boumghar, Fatima

    2017-02-01

    To examine the effects of MR acquisition parameters on brain white matter fiber orientation estimation and parameter of clinical interest in crossing fiber areas based on the Multi-Tensor Model (MTM). We compute the Cramér-Rao Bound (CRB) for the MTM and the parameter of clinical interest such as the Fractional Anisotropy (FA) and the dominant fiber orientations, assuming that the diffusion MRI data are recorded by a multi-coil, multi-shell acquisition system. Considering the sum-of-squares method for the reconstructed magnitude image, we introduce an approximate closed-form formula for Fisher Information Matrix that has the simplicity and easy interpretation advantages. In addition, we propose to generalize the FA and the mean diffusivity to the multi-tensor model. We show the application of the CRB to reduce the scan time while preserving a good estimation precision. We provide results showing how the increase of the number of acquisition coils compensates the decrease of the number of diffusion gradient directions. We analyze the impact of the b-value and the Signal-to-Noise Ratio (SNR). The analysis shows that the estimation error variance decreases with a quadratic rate with the SNR, and that the optimum b-values are not unique but depend on the target parameter, the context, and eventually the target cost function. In this study we highlight the importance of choosing the appropriate acquisition parameters especially when dealing with crossing fiber areas. We also provide a methodology for the optimal tuning of these parameters using the CRB. Copyright © 2016 Elsevier Inc. All rights reserved.

  12. Complete Fourier Direct Magnetic Resonance Imaging (CFD-MRI for Diffusion MRI

    Directory of Open Access Journals (Sweden)

    Alpay eÖzcan

    2013-04-01

    Full Text Available The foundation for an accurate and unifying Fourier based theory of diffusion weighted magnetic resonance imaging (DW-MRI is constructed by carefully re-examining the first principles of DW-MRI signal formation and deriving its mathematical model from scratch. The derivations are specifically obtained for DW-MRI signal by including all of its elements (e.g., imaging gradients using complex values. Particle methods are utilized in contrast to conventional partial differential equations approach. The signal is shown to be the Fourier transform of the joint distribution of number of the magnetic moments (at a given location at the initial time and magnetic moment displacement integrals. In effect, the k-space is augmented by three more dimensions, corresponding to the frequency variables dual to displacement integral vectors. The joint distribution function is recovered by applying the Fourier transform to the complete high-dimensional data set. In the process, to obtain a physically meaningful real valued distribution function, phase corrections are applied for the re-establishment of Hermitian symmetry in the signal. Consequently, the method is fully unconstrained and directly presents the distribution of displacement integrals without any assumptions such as symmetry or Markovian property. The joint distribution function is visualized with isosurfaces, which describe the displacement integrals, overlaid on the distribution map of the number of magnetic moments with low mobility. The model provides an accurate description of the molecular motion measurements via DW-MRI. The improvement of the characterization of tissue microstructure leads to a better localization, detection and assessment of biological properties such as white matter integrity. The results are demonstrated on the experimental data obtained from an ex-vivo baboon brain.

  13. Perpendicular Diffusion Coefficient of Comic Rays: The Presence of Weak Adiabatic Focusing

    Energy Technology Data Exchange (ETDEWEB)

    Wang, J. F.; Ma, Q. M.; Song, T.; Yuan, S. B. [Research Department of Biomedical Engineering, Institute of Electrical Engineering, Chinese Academy of Science, Beijing 100190 (China); Qin, G., E-mail: wangjunfang@mail.iee.ac.cn, E-mail: qingang@hit.edu.cn [School of Science, Harbin Institute of Technology, Shenzhen 518055 (China)

    2017-08-20

    The influence of adiabatic focusing on particle diffusion is an important topic in astrophysics and plasma physics. In the past, several authors have explored the influence of along-field adiabatic focusing on the parallel diffusion of charged energetic particles. In this paper, using the unified nonlinear transport theory developed by Shalchi and the method of He and Schlickeiser, we derive a new nonlinear perpendicular diffusion coefficient for a non-uniform background magnetic field. This formula demonstrates that the particle perpendicular diffusion coefficient is modified by along-field adiabatic focusing. For isotropic pitch-angle scattering and the weak adiabatic focusing limit, the derived perpendicular diffusion coefficient is independent of the sign of adiabatic focusing characteristic length. For the two-component model, we simplify the perpendicular diffusion coefficient up to the second order of the power series of the adiabatic focusing characteristic quantity. We find that the first-order modifying factor is equal to zero and that the sign of the second order is determined by the energy of the particles.

  14. The Influence of Conditioning Agent on Phosphate Diffusion Coefficient through Polyacrylamide and Agarose Gel

    Directory of Open Access Journals (Sweden)

    Layta Dinira

    2013-03-01

    Full Text Available Excess phosphate in natural water can cause algae grow rapidly, to the extent causing many fish deaths that led to the extinction of certain species. Therefore, an analysis or periodic observations of phosphate levels in the water is needed. The commonly used method is diffusive gradient in thin films (DGT technique. The DGT technique is based on the ability of analyte to diffuse through a gel, which have a value named diffusion coefficient. This research was conducted in order to study the effect of different storage solution to the phosphate diffusion coefficient through polyacrylamide and agarose gels. Initial research performed with making the polyacrylamide and agarose gels. To observe the effect of different storage solutions, the gels partly stored in distilled water gel while the others are stored in a NaCl solution of 0.01 M. Phosphate diffusion coefficient was determined using Fick's Law after analyze the phosphate concentration using UV-Visible spectrophotometer. The results showed that phosphate diffusion coefficient was highest when polyacrylamide and agarose gels stored in NaCl solution of 0.01 M.

  15. Diffusion coefficients of tracers in glassy polymer systems prepared by gamma radiolysis

    International Nuclear Information System (INIS)

    Tonge, M.P.; Gilbert, R.G.

    1996-01-01

    Diffusion-controlled reactions are common in free radical polymerisation reactions, especially in glassy polymer matrices. Such reactions commonly have an important influence on the polymerisation process and final polymer properties. For example, the dominant growth-stopping event (bimolecular termination) is generally diffusion-controlled. In glassy polymer systems, where molecular mobility is very low, the chain growth mechanism (propagation) may become diffusion-controlled. At present, the mechanism for propagation in glassy polymers is poorly understood, but it is expected by the Smoluchowski expression applied to propagation to depend strongly on the diffusion coefficient of monomer. The objective of this study is to measure reliable diffusion coefficients of small tracer molecules in glassy polymers, and compare these with propagation rate coefficients in similar systems, by the prediction above. Samples were initially prepared in a sealed sampled cell containing monomer, inert diluent, and tracer dye. After irradiation for several days, complete conversion of monomer to polymer can be obtained. The diffusion coefficients for two tracer dyes have been measured as a function of weight fraction polymer glassy poly(methyl methacrylate) samples

  16. Perpendicular Diffusion Coefficient of Comic Rays: The Presence of Weak Adiabatic Focusing

    Science.gov (United States)

    Wang, J. F.; Qin, G.; Ma, Q. M.; Song, T.; Yuan, S. B.

    2017-08-01

    The influence of adiabatic focusing on particle diffusion is an important topic in astrophysics and plasma physics. In the past, several authors have explored the influence of along-field adiabatic focusing on the parallel diffusion of charged energetic particles. In this paper, using the unified nonlinear transport theory developed by Shalchi and the method of He and Schlickeiser, we derive a new nonlinear perpendicular diffusion coefficient for a non-uniform background magnetic field. This formula demonstrates that the particle perpendicular diffusion coefficient is modified by along-field adiabatic focusing. For isotropic pitch-angle scattering and the weak adiabatic focusing limit, the derived perpendicular diffusion coefficient is independent of the sign of adiabatic focusing characteristic length. For the two-component model, we simplify the perpendicular diffusion coefficient up to the second order of the power series of the adiabatic focusing characteristic quantity. We find that the first-order modifying factor is equal to zero and that the sign of the second order is determined by the energy of the particles.

  17. Perpendicular Diffusion Coefficient of Comic Rays: The Presence of Weak Adiabatic Focusing

    International Nuclear Information System (INIS)

    Wang, J. F.; Ma, Q. M.; Song, T.; Yuan, S. B.; Qin, G.

    2017-01-01

    The influence of adiabatic focusing on particle diffusion is an important topic in astrophysics and plasma physics. In the past, several authors have explored the influence of along-field adiabatic focusing on the parallel diffusion of charged energetic particles. In this paper, using the unified nonlinear transport theory developed by Shalchi and the method of He and Schlickeiser, we derive a new nonlinear perpendicular diffusion coefficient for a non-uniform background magnetic field. This formula demonstrates that the particle perpendicular diffusion coefficient is modified by along-field adiabatic focusing. For isotropic pitch-angle scattering and the weak adiabatic focusing limit, the derived perpendicular diffusion coefficient is independent of the sign of adiabatic focusing characteristic length. For the two-component model, we simplify the perpendicular diffusion coefficient up to the second order of the power series of the adiabatic focusing characteristic quantity. We find that the first-order modifying factor is equal to zero and that the sign of the second order is determined by the energy of the particles.

  18. Estimation of the thermal diffusion coefficient in fusion plasmas taking frequency measurement uncertainties into account

    International Nuclear Information System (INIS)

    Van Berkel, M; Hogeweij, G M D; Van den Brand, H; De Baar, M R; Zwart, H J; Vandersteen, G

    2014-01-01

    In this paper, the estimation of the thermal diffusivity from perturbative experiments in fusion plasmas is discussed. The measurements used to estimate the thermal diffusivity suffer from stochastic noise. Accurate estimation of the thermal diffusivity should take this into account. It will be shown that formulas found in the literature often result in a thermal diffusivity that has a bias (a difference between the estimated value and the actual value that remains even if more measurements are added) or have an unnecessarily large uncertainty. This will be shown by modeling a plasma using only diffusion as heat transport mechanism and measurement noise based on ASDEX Upgrade measurements. The Fourier coefficients of a temperature perturbation will exhibit noise from the circular complex normal distribution (CCND). Based on Fourier coefficients distributed according to a CCND, it is shown that the resulting probability density function of the thermal diffusivity is an inverse non-central chi-squared distribution. The thermal diffusivity that is found by sampling this distribution will always be biased, and averaging of multiple estimated diffusivities will not necessarily improve the estimation. Confidence bounds are constructed to illustrate the uncertainty in the diffusivity using several formulas that are equivalent in the noiseless case. Finally, a different method of averaging, that reduces the uncertainty significantly, is suggested. The methodology is also extended to the case where damping is included, and it is explained how to include the cylindrical geometry. (paper)

  19. The diffusion coefficient as a function of energy for usual moderators; Le coefficient de diffusion en fonction de l'energie des thermaliseurs usuels

    Energy Technology Data Exchange (ETDEWEB)

    Cadilhac, M; Livolant, M; Pillard, D; Soule, J -L [Commissariat a l' Energie Atomique, Centre d' Etudes Nucleaires de Saclay, 91 - Gif-sur-Yvette (France)

    1966-07-01

    After a review of the definition of the energy function to be taken for the diffusion coefficient used in calculations of reactor cells, in the elementary theory of diffusion, various possible approximations of this function are given. These approximations are shown to be accurate enough for practical uses. Methods for the direct calculations of these approximations for the currently used 'normal' models (methods avoiding the calculation of differential cross sections) are described; these methods are applied to several usual moderators at various temperatures according to different models. (authors) [French] On rappelle la definition de la fonction de l'energie que l'on doit prendre pour le coefficient de diffusion dans les calculs de cellule de reacteur en theorie elementaire de la diffusion. Puis on indique diverses approximations possibles de cette fonction. On montre que ces approximations ont en pratique une precision suffisante. Enfin on decrit des methodes de calcul direct de ces approximations pour les modeles 'normaux' couramment employes (methodes qui evitent d'avoir a calculer les sections efficaces differentielles), et on les applique a plusieurs thermaliseurs usuels a differentes temperatures (selon differents modeles). (auteurs)

  20. Combined measurement of surface, grain boundary and lattice diffusion coefficients on olivine bi-crystals

    Science.gov (United States)

    Marquardt, Katharina; Dohmen, Ralf; Wagner, Johannes

    2014-05-01

    Diffusion along interface and grain boundaries provides an efficient pathway and may control chemical transport in rocks as well as their mechanical strength. Besides the significant relevance of these diffusion processes for various geologic processes, experimental data are still very limited (e.g., Dohmen & Milke, 2010). Most of these data were measured using polycrystalline materials and the formalism of LeClaire (1951) to fit integrated concentration depth profiles. To correctly apply this formalism, certain boundary conditions of the diffusion problem need to be fulfilled, e.g., surface diffusion is ignored, and furthermore the lattice diffusion coefficient has to be known from other studies or is an additional fitting parameter, which produces some ambiguity in the derived grain boundary diffusion coefficients. We developed an experimental setup where we can measure the lattice and grain boundary diffusion coefficients simultaneously but independent and demonstrate the relevance of surface diffusion for typical grain boundary diffusion experiments. We performed Mg2SiO4 bicrystal diffusion experiments, where a single grain boundary is covered by a thin-film of pure Ni2SiO4 acting as diffusant source, produced by pulsed laser deposition. The investigated grain boundary is a 60° (011)/[100]. This specific grain boundary configuration was modeled using molecular dynamics for comparison with the experimental observations in the transmission electron microscope (TEM). Both, experiment and model are in good agreement regarding the misorientation, whereas there are still some disagreements regarding the strain fields along the grain boundary that are of outmost importance for the strengths of the material. The subsequent diffusion experiments were carried out in the temperature range between 800° and 1450° C. The inter diffusion profiles were measured using the TEMs energy dispersive x-ray spectrometer standardized using the Cliff-Lorimer equation and EMPA

  1. Whole-body MRI, dynamic contrast-enhanced MRI, and diffusion-weighted imaging for the staging of multiple myeloma

    Energy Technology Data Exchange (ETDEWEB)

    Dutoit, Julie C.; Verstraete, Koenraad L. [Ghent University Hospital, Department of Radiology, Ghent (Belgium)

    2017-06-15

    Magnetic resonance imaging (MRI) is the most sensitive imaging technique for the detection of bone marrow infiltration, and has therefore recently been included in the new diagnostic myeloma criteria, as proposed by the International Myeloma Working Group. Nevertheless, conventional MRI only provides anatomical information and is therefore only of limited use in the response assessment of patients with multiple myeloma. The additional information from functional MRI techniques, such as diffusion-weighted imaging and dynamic contrast-enhanced MRI, can improve the detection rate of bone marrow infiltration and the assessment of response. This can further enhance the sensitivity and specificity of MRI in the staging of multiple myeloma patients. This article provides an overview of the technical aspects of conventional and functional MRI techniques with practical recommendations. It reviews the diagnostic performance, prognostic value, and role in therapy assessment in multiple myeloma and its precursor stages. (orig.)

  2. Diffusion-weighted imaging and dynamic contrast-enhanced MRI of experimental breast cancer bone metastases – A correlation study with histology

    Energy Technology Data Exchange (ETDEWEB)

    Merz, Maximilian [Department of Medical Physics in Radiology, German Cancer Research Center, Im Neuenheimer Feld 280, 69120 Heidelberg (Germany); Department of Hematology, Oncology and Rheumatology, Heidelberg University Hospital, Im Neuenheimer Feld 410, 69120 Heidelberg (Germany); Seyler, Lisa; Bretschi, Maren; Semmler, Wolfhard [Department of Medical Physics in Radiology, German Cancer Research Center, Im Neuenheimer Feld 280, 69120 Heidelberg (Germany); Bäuerle, Tobias, E-mail: tobias.baeuerle@uk-erlangen.de [Department of Medical Physics in Radiology, German Cancer Research Center, Im Neuenheimer Feld 280, 69120 Heidelberg (Germany); Institute of Radiology, University Medical Center Erlangen, Palmsanlage 5, 90154 Erlangen (Germany)

    2015-04-15

    Purpose: To validate imaging parameters from diffusion-weighted imaging and dynamic contrast-enhanced MRI with immunohistology and to non-invasively assess microstructure of experimental breast cancer bone metastases. Materials and methods: Animals bearing breast cancer bone metastases were imaged in a clinical 1.5 T MRI scanner. HASTE sequences were performed to calculate apparent diffusion coefficients. Saturation recovery turbo FLASH sequences were conducted while infusing 0.1 mmol/l Gd–DTPA for dynamic contrast-enhanced MRI to quantify parameters amplitude A and exchange rate constant k{sub ep}. After imaging, bone metastases were analyzed immunohistologically. Results: We found correlations of the apparent diffusion coefficients from diffusion-weighted imaging with tumor cellularity as assessed with cell nuclei staining. Histological vessel maturity was correlated negatively with parameters A and k{sub ep} from dynamic contrast-enhanced MRI. Tumor size correlated inversely with cell density and vessel permeability as well as positively with mean vessel calibers. Parameters from the rim of bone metastases differed significantly from values of the center. Conclusion: In vivo diffusion-weighted imaging and dynamic contrast-enhanced MRI in experimental bone metastases provide information about tumor cellularity and vascularity and correlate well with immunohistology.

  3. Crack diffusion coefficient - A candidate fracture toughness parameter for short fiber composites

    Science.gov (United States)

    Mull, M. A.; Chudnovsky, A.; Moet, A.

    1987-01-01

    In brittle matrix composites, crack propagation occurs along random trajectories reflecting the heterogeneous nature of the strength field. Considering the crack trajectory as a diffusive process, the 'crack diffusion coefficient' is introduced. From fatigue crack propagation experiments on a set of identical SEN polyester composite specimens, the variance of the crack tip position along the loading axis is found to be a linear function of the effective 'time'. The latter is taken as the effective crack length. The coefficient of proportionality between variance of the crack trajectory and the effective crack length defines the crack diffusion coefficient D which is found in the present study to be 0.165 mm. This parameter reflects the ability of the composite to deviate the crack from the energetically most efficient path and thus links fracture toughness to the microstructure.

  4. New method and installation for rapid determination of radon diffusion coefficient in various materials.

    Science.gov (United States)

    Tsapalov, Andrey; Gulabyants, Loren; Livshits, Mihail; Kovler, Konstantin

    2014-04-01

    The mathematical apparatus and the experimental installation for the rapid determination of radon diffusion coefficient in various materials are developed. The single test lasts not longer than 18 h and allows testing numerous materials, such as gaseous and liquid media, as well as soil, concrete and radon-proof membranes, in which diffusion coefficient of radon may vary in an extremely wide range, from 1·10(-12) to 5·10(-5) m(2)/s. The uncertainty of radon diffusion coefficient estimation depends on the permeability of the sample and varies from about 5% (for the most permeable materials) to 40% (for less permeable materials, such as radon-proof membranes). Copyright © 2014. Published by Elsevier Ltd.

  5. Non-destructive testing method for determining the solvent diffusion coefficient in the porous materials products

    Science.gov (United States)

    Belyaev, V. P.; Mishchenko, S. V.; Belyaev, P. S.

    2018-01-01

    Ensuring non-destructive testing of products in industry is an urgent task. Most of the modern methods for determining the diffusion coefficient in porous materials have been developed for bodies of a given configuration and size. This leads to the need for finished products destruction to make experimental samples from them. The purpose of this study is the development of a dynamic method that allows operatively determine the diffusion coefficient in finished products from porous materials without destroying them. The method is designed to investigate the solvents diffusion coefficient in building constructions from materials having a porous structure: brick, concrete and aerated concrete, gypsum, cement, gypsum or silicate solutions, gas silicate blocks, heat insulators, etc. A mathematical model of the method is constructed. The influence of the design and measuring device operating parameters on the method accuracy is studied. The application results of the developed method for structural porous products are presented.

  6. Temperature dependence of diffusion coefficients of trivalent uranium ions in chloride and chloride-fluoride melts

    International Nuclear Information System (INIS)

    Komarov, V.E.; Borodina, N.P.

    1981-01-01

    Diffusion coefficients of U 3+ ions are measured by chronopotentiometric method in chloride 3LiCl-2KCl and in mixed chloride fluoride 3LiCl(LiF)-2KCl melts in the temperature range 633-1235 K. It is shown It is shown that experimental values of diffusion-coefficients are approximated in a direct line in lg D-1/T coordinate in chloride melt in the whole temperature range and in chloride-fluoride melt in the range of 644-1040 K. Experimental values of diffusion coefficients diviate from Arrhenius equation in the direction of large values in chloride-fluoride melt at further increase of temperature up to 1235 K. Possible causes of such a diviation are considered [ru

  7. Diffusion coefficients of gaseous scavengers in organic liquids used in radiation chemistry

    International Nuclear Information System (INIS)

    Luthjens, L.H.; De Leng, H.C.; Warman, J.M.; Hummel, A.

    1990-01-01

    Diffusion coefficients have been measured of some gaseous scavengers commonly used in radiation chemical studies: CO 2 , NH 3 , SF 6 and O 2 in trans-decalin, cyclohexane, isooctane and n-hexane, and CO 2 in cis-decalin, at 25 0 C. A modified diaphragm cell method has been used in order to limit the time needed for a measurement to about 6 h. Analysis of the results yields a simple semi-empirical predictive relation for the diffusion coefficient of a (gaseous) solute A in an organic solvent B. Diffusion coefficients calculated using the simple relation appear to give results in fair agreement with published values, over a range of organic solvents including alcohols, and over a range of temperatures. Some measured and predicted values are discussed with reference to results from the literature. (author)

  8. Assessment and quantification of sources of variability in breast apparent diffusion coefficient (ADC) measurements at diffusion weighted imaging

    International Nuclear Information System (INIS)

    Giannotti, E.; Waugh, S.; Priba, L.; Davis, Z.; Crowe, E.; Vinnicombe, S.

    2015-01-01

    Highlights: • Inter-scan errors have minimal contribution to ADC measurement variability. • Intra-observer measures of ADC values in breast cancer are excellent. • ADC measures in whole tumour are more reproducible than minimum ADC measures. • ADC measurement error is most influenced by multiple readers. - Abstract: Purpose: Apparent Diffusion Coefficient (ADC) measurements are increasingly used for assessing breast cancer response to neoadjuvant chemotherapy although little data exists on ADC measurement reproducibility. The purpose of this work was to investigate and characterise the magnitude of errors in ADC measures that may be encountered in such follow-up studies- namely scanner stability, scan–scan reproducibility, inter- and intra- observer measures and the most reproducible measurement of ADC. Methods: Institutional Review Board approval was obtained for the prospective study of healthy volunteers and written consent acquired for the retrospective study of patient images. All scanning was performed on a 3.0-T MRI scanner. Scanner stability was assessed using an ice-water phantom weekly for 12 weeks. Inter-scan repeatability was assessed across two scans of 10 healthy volunteers (26–61 years; mean: 44.7 years). Inter- and intra-reader analysis repeatability was measured in 52 carcinomas from clinical patients (29–70 years; mean: 50.0 years) by measuring the whole tumor ADC value on a single slice with maximum tumor diameter (ADC S ) and the ADC value of a small region of interest (ROI) on the same slice (ADC min ). Repeatability was assessed using intraclass correlation coefficients (ICC) and coefficients of repeatability (CoR). Results: Scanner stability contributed 6% error to phantom ADC measurements (0.071 × 10 −3 mm 2 /s; mean ADC = 1.089 × 10 −3 mm 2 /s). The measured scan-scan CoR in the volunteers was 0.122 × 10 −3 mm 2 /s, contributing an error of 8% to the mean measured values (ADC scan1 = 1.529 × 10 −3 mm 2 /s; ADC scan

  9. Assessment and quantification of sources of variability in breast apparent diffusion coefficient (ADC) measurements at diffusion weighted imaging

    Energy Technology Data Exchange (ETDEWEB)

    Giannotti, E., E-mail: ytteb84@hotmail.com [Breast Imaging Department, Ninewells Hospital and Medical School, Dundee DD1 9SY (United Kingdom); Waugh, S., E-mail: shelley.waugh@nhs.net [Department of Medical Physics, Ninewells Hospital and Medical School, Dundee DD1 9SY (United Kingdom); Department of Clinical Radiology, Ninewells Hospital and Medical School, Dundee DD1 9SY (United Kingdom); Priba, L., E-mail: lpriba@nhs.net [Department of Medical Physics, Ninewells Hospital and Medical School, Dundee DD1 9SY (United Kingdom); Davis, Z., E-mail: zoedavis@doctors.org.uk [Breast Imaging Department, Ninewells Hospital and Medical School, Dundee DD1 9SY (United Kingdom); Crowe, E., E-mail: e.crowe@nhs.net [Department of Clinical Radiology, Ninewells Hospital and Medical School, Dundee DD1 9SY (United Kingdom); Vinnicombe, S., E-mail: s.vinnicombe@dundee.ac.uk [Division of Imaging and Technology, Ninewells Hospital and Medical School, University of Dundee, Dundee DD1 9SY (United Kingdom)

    2015-09-15

    Highlights: • Inter-scan errors have minimal contribution to ADC measurement variability. • Intra-observer measures of ADC values in breast cancer are excellent. • ADC measures in whole tumour are more reproducible than minimum ADC measures. • ADC measurement error is most influenced by multiple readers. - Abstract: Purpose: Apparent Diffusion Coefficient (ADC) measurements are increasingly used for assessing breast cancer response to neoadjuvant chemotherapy although little data exists on ADC measurement reproducibility. The purpose of this work was to investigate and characterise the magnitude of errors in ADC measures that may be encountered in such follow-up studies- namely scanner stability, scan–scan reproducibility, inter- and intra- observer measures and the most reproducible measurement of ADC. Methods: Institutional Review Board approval was obtained for the prospective study of healthy volunteers and written consent acquired for the retrospective study of patient images. All scanning was performed on a 3.0-T MRI scanner. Scanner stability was assessed using an ice-water phantom weekly for 12 weeks. Inter-scan repeatability was assessed across two scans of 10 healthy volunteers (26–61 years; mean: 44.7 years). Inter- and intra-reader analysis repeatability was measured in 52 carcinomas from clinical patients (29–70 years; mean: 50.0 years) by measuring the whole tumor ADC value on a single slice with maximum tumor diameter (ADC{sub S}) and the ADC value of a small region of interest (ROI) on the same slice (ADC{sub min}). Repeatability was assessed using intraclass correlation coefficients (ICC) and coefficients of repeatability (CoR). Results: Scanner stability contributed 6% error to phantom ADC measurements (0.071 × 10{sup −3} mm{sup 2}/s; mean ADC = 1.089 × 10{sup −3} mm{sup 2}/s). The measured scan-scan CoR in the volunteers was 0.122 × 10{sup −3} mm{sup 2}/s, contributing an error of 8% to the mean measured values (ADC

  10. Optimising diffusion weighted MRI for imaging metastatic and myeloma bone disease and assessing reproducibility

    International Nuclear Information System (INIS)

    Messiou, C.; Collins, D.J.; Morgan, V.A.; DeSouza, N.M.

    2011-01-01

    To establish normal bone marrow values of apparent diffusion coefficient (ADC) over an age range, compare them with metastatic and myelomatous involvement, to establish reproducibility and to optimise b values. The ADCs of bone marrow in 7 volunteers (mean age 29.7 years), 34 volunteers (mean age 63.3 years) and 43 patients with metastatic and myelomatous involvement (mean age 65.5 years) were measured. In 9 volunteers diffusion weighted MRI was repeated within 7 days. b values were derived to optimise contrast between normal and pathological marrow. The mean ADC of bone marrow in younger volunteers was significantly higher than that of older volunteers. The coefficient of reproducibility was 14.8%. The ADC mean of metastatic and myeloma bone disease was 1054+/-456 x 10 -6 mm 2 s -1 . An ADC threshold of 655 x 10 -6 mm 2 s -1 separated normal and abnormal marrow with a sensitivity and specificity of 90% and 93% respectively. Contrast between normal and abnormal marrow was optimal at b = 1389 smm -2 . The reproducibility of ADC measurements in bone is equivalent to published data for soft tissue with a high sensitivity and specificity for separating abnormal from age matched normal bone marrow. A b value of around 1,400 smm -2 is optimal for imaging bone marrow. (orig.)

  11. Optimising diffusion weighted MRI for imaging metastatic and myeloma bone disease and assessing reproducibility

    Energy Technology Data Exchange (ETDEWEB)

    Messiou, C. [Institute of Cancer Research and Royal Marsden, NHS Foundation Trust, Cancer Research UK Clinical Magnetic Resonance Research Group, Surrey (United Kingdom); Institute of Cancer Research and Royal Marsden, NHS Foundation Trust, MRI Department, Surrey (United Kingdom); Collins, D.J.; Morgan, V.A.; DeSouza, N.M. [Institute of Cancer Research and Royal Marsden, NHS Foundation Trust, Cancer Research UK Clinical Magnetic Resonance Research Group, Surrey (United Kingdom)

    2011-08-15

    To establish normal bone marrow values of apparent diffusion coefficient (ADC) over an age range, compare them with metastatic and myelomatous involvement, to establish reproducibility and to optimise b values. The ADCs of bone marrow in 7 volunteers (mean age 29.7 years), 34 volunteers (mean age 63.3 years) and 43 patients with metastatic and myelomatous involvement (mean age 65.5 years) were measured. In 9 volunteers diffusion weighted MRI was repeated within 7 days. b values were derived to optimise contrast between normal and pathological marrow. The mean ADC of bone marrow in younger volunteers was significantly higher than that of older volunteers. The coefficient of reproducibility was 14.8%. The ADC mean of metastatic and myeloma bone disease was 1054+/-456 x 10{sup -6} mm{sup 2}s{sup -1}. An ADC threshold of 655 x 10{sup -6} mm{sup 2}s{sup -1} separated normal and abnormal marrow with a sensitivity and specificity of 90% and 93% respectively. Contrast between normal and abnormal marrow was optimal at b = 1389 smm{sup -2}. The reproducibility of ADC measurements in bone is equivalent to published data for soft tissue with a high sensitivity and specificity for separating abnormal from age matched normal bone marrow. A b value of around 1,400 smm{sup -2} is optimal for imaging bone marrow. (orig.)

  12. [Characteristics of high resolution diffusion weighted imaging apparent diffusion coefficient histogram and its correlations with cancer stages in patients with nasopharyngeal carcinoma].

    Science.gov (United States)

    Wang, G J; Wang, Y; Ye, Y; Chen, F; Lu, Y T; Li, S L

    2017-11-07

    Objective: To investigate the features of apparent diffusion coefficient (ADC) histogram parameters based on entire tumor volume data in high resolution diffusion weighted imaging of nasopharyngeal carcinoma (NPC) and to evaluate its correlations with cancer stages. Methods: This retrospective study included 154 cases of NPC patients[102 males and 52 females, mean age (48±11) years]who had received readout segmentation of long variable echo trains of MRI scan before radiation therapy. The area of tumor was delineated on each section of axial ADC maps to generate ADC histogram by using Image J. ADC histogram of entire tumor along with the histogram parameters-the tumor voxels, ADC(mean), ADC(25%), ADC(50%), ADC(75%), skewness and kurtosis were obtained by merging all sections with SPSS 22.0 software. Intra-observer repeatability was assessed by using intra-class correlation coefficients (ICC). The patients were subdivided into two groups according to cancer volume: small cancer group (histogram parameters and cancer stages was evaluated with Spearman test. Results: The ICC of measuring ADC histogram parameters of tumor voxels, ADC(mean), ADC(25%), ADC(50%), ADC(75%), skewness, kurtosis was 0.938, 0.861, 0.885, 0.838, 0.836, 0.358 and 0.456, respectively. The tumor voxels was positively correlated with T staging ( r =0.368, P histogram (ADC(mean), ADC(25%), ADC(50%)) increases with T staging in NPC smaller than 2 cm(3).

  13. Measurement of the local particle diffusion coefficient in a magnetized plasma

    International Nuclear Information System (INIS)

    Meyerhofer, D.D.; Levinton, F.M.

    1987-02-01

    Local impurity particle diffusion coefficients have been measured in a low temperature plasma by the injection of test particles at the center of the plasma. The injection is accomplished by a high voltage discharge between two small graphite electrodes on a probe. The probe can be located anywhere in the plasma. The diffusion is observed spectroscopically. An analysis of the spatial and temporal evolution of the CII radiation from the carbon discharge can determine the parallel and perpendicular diffusion of the impurity ions. Results with the diagnostic have been obtained in the Proto S-1/C spheromak. The measured value of the diffusion coefficient in the afterglow plasma is in good agreement with classical predictions

  14. Interferometric measurement of a diffusion coefficient: comparison of two methods and uncertainty analysis

    International Nuclear Information System (INIS)

    Riquelme, Rodrigo; Lira, Ignacio; Perez-Lopez, Carlos; Rayas, Juan A; RodrIguez-Vera, Ramon

    2007-01-01

    Two methods to measure the diffusion coefficient of a species in a liquid by optical interferometry were compared. The methods were tested on a 1.75 M NaCl aqueous solution diffusing into water at 26 deg. C. Results were D = 1.587 x 10 -9 m 2 s -1 with the first method and D = 1.602 x 10 -9 m 2 s -1 with the second method. Monte Carlo simulation was used to assess the possible dispersion of these results. The standard uncertainties were found to be of the order of 0.05 x 10 -9 m 2 s -1 with both methods. We found that the value of the diffusion coefficient obtained by either method is very sensitive to the magnification of the optical system, and that if diffusion is slow the measurement of time does not need to be very accurate

  15. New sensitive micro-measurements of dynamic surface tension and diffusion coefficients

    DEFF Research Database (Denmark)

    Kinoshita, Koji; Ortiz, Elisa Parra; Needham, David

    2017-01-01

    Currently available dynamic surface tension (DST) measurement methods, such as Wilhelmy plate, droplet- or bubble-based methods, still have various experimental limitations such as the large size of the interface, convection in the solution, or a certain “dead time” at initial measurement....... These limitations create inconsistencies for the kinetic analysis of surfactant adsorption/desorption, especially significant for ionic surfactants. Here, the “micropipette interfacial area-expansion method” was introduced and validated as a new DST measurement having a high enough sensitivity to detect diffusion...... for surface excess concentration. We found that the measured diffusion coefficient of 1-Octanol, 7.2 ± 0.8 × 10−6 cm2/s, showed excellent agreement with the result from an alternative method, “single microdroplet catching method”, to measure the diffusion coefficient from diffusion-controlled microdroplet...

  16. Distortion-free diffusion MRI using an MRI-guided Tri-Cobalt 60 radiotherapy system: Sequence verification and preliminary clinical experience.

    Science.gov (United States)

    Gao, Yu; Han, Fei; Zhou, Ziwu; Cao, Minsong; Kaprealian, Tania; Kamrava, Mitchell; Wang, Chenyang; Neylon, John; Low, Daniel A; Yang, Yingli; Hu, Peng

    2017-10-01

    Monitoring tumor response during the course of treatment and adaptively modifying treatment plan based on tumor biological feedback may represent a new paradigm for radiotherapy. Diffusion MRI has shown great promises in assessing and predicting tumor response to radiotherapy. However, the conventional diffusion-weighted single-shot echo-planar-imaging (DW-ssEPI) technique suffers from limited resolution, severe distortion, and possibly inaccurate ADC at low field strength. The purpose of this work was to develop a reliable, accurate and distortion-free diffusion MRI technique that is practicable for longitudinal tumor response evaluation and adaptive radiotherapy on a 0.35 T MRI-guided radiotherapy system. A diffusion-prepared turbo spin echo readout (DP-TSE) sequence was developed and compared with the conventional diffusion-weighted single-shot echo-planar-imaging sequence on a 0.35 T MRI-guided radiotherapy system (ViewRay). A spatial integrity phantom was used to quantitate and compare the geometric accuracy of the two diffusion sequences for three orthogonal orientations. The apparent diffusion coefficient (ADC) accuracy was evaluated on a diffusion phantom under both 0 °C and room temperature to cover a diffusivity range between 0.40 × 10 -3 and 2.10 × 10 -3 mm 2 /s. Ten room temperature measurements repeated on five different days were conducted to assess the ADC reproducibility of DP-TSE. Two glioblastoma (GBM) and six sarcoma patients were included to examine the in vivo feasibility. The target registration error (TRE) was calculated to quantitate the geometric accuracy where structural CT or MR images were co-registered to the diffusion images as references. ADC maps from DP-TSE and DW-ssEPI were calculated and compared. A tube phantom was placed next to patients not treated on ViewRay, and ADCs of this reference tube were also compared. The proposed DP-TSE passed the spatial integrity test (< 1 mm within 100 mm radius and < 2 mm within 175 mm radius

  17. Diffusion-weighted MRI of malignant versus benign portal vein thrombosis

    Energy Technology Data Exchange (ETDEWEB)

    Ahn, Jhii Hyun; Yu, Jeong Sik; Cho, Eun Suk; Chung, Jae Joon; Kim, Joo Hee; Kim, Ki Whang [Yonsei University College of Medicine, Gangnam Severance Hospital, Seoul(Korea, Republic of)

    2016-07-15

    To validate the diffusion-weighted MRI (DWI) for differentiation of benign from malignant portal vein thrombosis. The Institutional Review Board approved this retrospective study and waived informed consent. A total of 59 consecutive patients (52 men and 7 women, aged 40-85 years) with grossly defined portal vein thrombus (PVT) on hepatic MRI were retrospectively analyzed. Among them, liver cirrhosis was found in 45 patients, and hepatocellular carcinoma in 47 patients. DWI was performed using b values of 50 and 800 sec/mm2 at 1.5-T unit. A thrombus was considered malignant if it enhanced on dynamic CT or MRI; otherwise, it was considered bland. There were 18 bland thrombi and 49 malignant thrombi in 59 patients, including 8 patients with simultaneous benign and malignant PVT. Mean apparent diffusion coefficients (ADCs) of benign and malignant PVTs were compared by using Mann-Whitney U test. Diagnostic accuracy was evaluated using receiver operating characteristic (ROC) curve analysis. The mean ADC ± standard deviation of bland and malignant PVT were 1.00 ± 0.39 × 10(-3) mm{sup 2}/sec and 0.92 ± 0.25 × 10(-3) mm{sup 2}/sec, respectively; without significant difference (p = 0.799). The area under ROC curve for ADC was 0.520. An ADC value of > 1.35 × 10(-3) mm{sup 2}/sec predicted bland PVT with a specificity of 94.6% (95% confidence interval [CI]: 84.9-98.9%) and a sensitivity of 22.2% (95% CI: 6.4-47.6%), respectively. Due to the wide range and considerable overlap of the ADCs, DWI cannot differentiate the benign from malignant thrombi efficiently.

  18. Diffusion-weighted MRI of malignant versus benign portal vein thrombosis

    International Nuclear Information System (INIS)

    Ahn, Jhii Hyun; Yu, Jeong Sik; Cho, Eun Suk; Chung, Jae Joon; Kim, Joo Hee; Kim, Ki Whang

    2016-01-01

    To validate the diffusion-weighted MRI (DWI) for differentiation of benign from malignant portal vein thrombosis. The Institutional Review Board approved this retrospective study and waived informed consent. A total of 59 consecutive patients (52 men and 7 women, aged 40-85 years) with grossly defined portal vein thrombus (PVT) on hepatic MRI were retrospectively analyzed. Among them, liver cirrhosis was found in 45 patients, and hepatocellular carcinoma in 47 patients. DWI was performed using b values of 50 and 800 sec/mm2 at 1.5-T unit. A thrombus was considered malignant if it enhanced on dynamic CT or MRI; otherwise, it was considered bland. There were 18 bland thrombi and 49 malignant thrombi in 59 patients, including 8 patients with simultaneous benign and malignant PVT. Mean apparent diffusion coefficients (ADCs) of benign and malignant PVTs were compared by using Mann-Whitney U test. Diagnostic accuracy was evaluated using receiver operating characteristic (ROC) curve analysis. The mean ADC ± standard deviation of bland and malignant PVT were 1.00 ± 0.39 × 10(-3) mm 2 /sec and 0.92 ± 0.25 × 10(-3) mm 2 /sec, respectively; without significant difference (p = 0.799). The area under ROC curve for ADC was 0.520. An ADC value of > 1.35 × 10(-3) mm 2 /sec predicted bland PVT with a specificity of 94.6% (95% confidence interval [CI]: 84.9-98.9%) and a sensitivity of 22.2% (95% CI: 6.4-47.6%), respectively. Due to the wide range and considerable overlap of the ADCs, DWI cannot differentiate the benign from malignant thrombi efficiently

  19. Diffusion-Weighted MRI of Malignant versus Benign Portal Vein Thrombosis

    Energy Technology Data Exchange (ETDEWEB)

    Ahn, Jhii-Hyun; Yu, Jeong-Sik; Cho, Eun-Suk; Chung, Jae-Joon; Kim, Joo Hee; Kim, Ki Whang [Department of Radiology, Yonsei University College of Medicine, Gangnam Severance Hospital, Seoul 06273 (Korea, Republic of)

    2016-11-01

    To validate the diffusion-weighted MRI (DWI) for differentiation of benign from malignant portal vein thrombosis. The Institutional Review Board approved this retrospective study and waived informed consent. A total of 59 consecutive patients (52 men and 7 women, aged 40–85 years) with grossly defined portal vein thrombus (PVT) on hepatic MRI were retrospectively analyzed. Among them, liver cirrhosis was found in 45 patients, and hepatocellular carcinoma in 47 patients. DWI was performed using b values of 50 and 800 sec/mm{sup 2} at 1.5-T unit. A thrombus was considered malignant if it enhanced on dynamic CT or MRI; otherwise, it was considered bland. There were 18 bland thrombi and 49 malignant thrombi in 59 patients, including 8 patients with simultaneous benign and malignant PVT. Mean apparent diffusion coefficients (ADCs) of benign and malignant PVTs were compared by using Mann-Whitney U test. Diagnostic accuracy was evaluated using receiver operating characteristic (ROC) curve analysis. The mean ADC ± standard deviation of bland and malignant PVT were 1.00 ± 0.39 × 10{sup -3} mm{sup 2}/sec and 0.92 ± 0.25 × 10{sup -3} mm{sup 2}/sec, respectively; without significant difference (p = 0.799). The area under ROC curve for ADC was 0.520. An ADC value of > 1.35 × 10{sup -3} mm{sup 2}/sec predicted bland PVT with a specificity of 94.6% (95% confidence interval [CI]: 84.9–98.9%) and a sensitivity of 22.2% (95% CI: 6.4–47.6%), respectively. Due to the wide range and considerable overlap of the ADCs, DWI cannot differentiate the benign from malignant thrombi efficiently.

  20. Can MRI diffusion-weighted imaging identify postoperative residual/recurrent soft-tissue sarcomas?

    Directory of Open Access Journals (Sweden)

    Mai Maher ElDaly

    2018-01-01

    Full Text Available Purpose: The aim of this study was to evaluate contrast-enhanced magnetic resonance imaging (CE-MRI and quantitative diffusion-weighted imaging (DWI with apparent diffusion coefficient (ADC mapping in the detection of recurrent/residual postoperative soft tissue sarcomas. Materials and Methods: This study included 36 patients; 27 patients had postoperative recurrent/residual soft tissue sarcomas and 9 patients had postoperative and treatment-related changes (inflammation/fibrosis. The DWI was obtained with 3 b values including 0, 400, and 800 s/mm2. Calculation of the ADC value of the lesion was done via placing the region of interest (ROI to include the largest area of the lesion. ADC values were compared to histopathology. Results: Our results showed that including CE-MRI improved the diagnostic accuracy and sensitivity in recurrence detection compared to conventional non-enhanced sequences. However, it showed low specificity (55.56% with a high false-positive rate that may lead to an unnecessary biopsy of a mass such as region of postoperative scar tissue. Conclusion: The joint use of gadolinium-enhanced MRI and quantitative DWI with ADC mapping offer added value in the detection of recurrent/residual postoperative soft tissue sarcoma. This combined use increased both the diagnostic sensitivity and specificity with a cut-off average ADC value for detecting nonmyxoid recurrent/residual lesions ≤1.3 × 10−3 mm2/s (100% specificity and 90.48% sensitivity. Our results showed limited value of DWI with ADC mapping in assessing myxoid sarcomatous tumor recurrences.

  1. Diffusion-Weighted MRI of Malignant versus Benign Portal Vein Thrombosis

    International Nuclear Information System (INIS)

    Ahn, Jhii-Hyun; Yu, Jeong-Sik; Cho, Eun-Suk; Chung, Jae-Joon; Kim, Joo Hee; Kim, Ki Whang

    2016-01-01

    To validate the diffusion-weighted MRI (DWI) for differentiation of benign from malignant portal vein thrombosis. The Institutional Review Board approved this retrospective study and waived informed consent. A total of 59 consecutive patients (52 men and 7 women, aged 40–85 years) with grossly defined portal vein thrombus (PVT) on hepatic MRI were retrospectively analyzed. Among them, liver cirrhosis was found in 45 patients, and hepatocellular carcinoma in 47 patients. DWI was performed using b values of 50 and 800 sec/mm 2 at 1.5-T unit. A thrombus was considered malignant if it enhanced on dynamic CT or MRI; otherwise, it was considered bland. There were 18 bland thrombi and 49 malignant thrombi in 59 patients, including 8 patients with simultaneous benign and malignant PVT. Mean apparent diffusion coefficients (ADCs) of benign and malignant PVTs were compared by using Mann-Whitney U test. Diagnostic accuracy was evaluated using receiver operating characteristic (ROC) curve analysis. The mean ADC ± standard deviation of bland and malignant PVT were 1.00 ± 0.39 × 10 -3 mm 2 /sec and 0.92 ± 0.25 × 10 -3 mm 2 /sec, respectively; without significant difference (p = 0.799). The area under ROC curve for ADC was 0.520. An ADC value of > 1.35 × 10 -3 mm 2 /sec predicted bland PVT with a specificity of 94.6% (95% confidence interval [CI]: 84.9–98.9%) and a sensitivity of 22.2% (95% CI: 6.4–47.6%), respectively. Due to the wide range and considerable overlap of the ADCs, DWI cannot differentiate the benign from malignant thrombi efficiently

  2. Diffusion coefficients of rare earth elements in fcc Fe: A first-principles study

    Science.gov (United States)

    Wang, Haiyan; Gao, Xueyun; Ren, Huiping; Chen, Shuming; Yao, Zhaofeng

    2018-01-01

    The diffusion data and corresponding detailed insights are particularly important for the understanding of the related kinetic processes in Fe based alloys, e.g. solute strengthening, phase transition, solution treatment etc. We present a density function theory study of the diffusivity of self and solutes (La, Ce, Y and Nb) in fcc Fe. The five-frequency model was employed to calculate the microscopic parameters in the correlation factors of the solute diffusion. The interactions of the solutes with the first nearest-neighbor vacancy (1nn) are all attractive, and can be well understood on the basis of the combination of the strain-relief effects and the electronic effects. It is found that among the investigated species, Ce is the fastest diffusing solute in fcc Fe matrix followed by Nb, and the diffusion coefficients of these two solutes are about an order of magnitude higher than that of Fe self-diffusion. And the results show that the diffusion coefficient of La is slightly higher than that of Y, and both species are comparable to that of Fe self-diffusion.

  3. The value of the apparent diffusion coefficient in MR diffusion weighted imaging for the differential diagnosis of sinonasal masses

    International Nuclear Information System (INIS)

    Wang Yongzhe; Yang Bentao; Xian Junfang; Li Jing; Chen Guangli

    2014-01-01

    Objective: To investigate the diagnostic value of apparent diffusion coefficient in the evaluation of sinonasal masses. Methods: Sixty-seven sinonasal solid masses over 1 cm in diameter confirmed by pathology were retrospectively analyzed, all patients underwent preoperative routine MRI with DWI, the ADC values were measured in ROI within the solid mass. The patients were divided into benign and malignant groups by the histopathology, according to pathological findings, the patients were further divided into the hematolymphoid tumors, the malignancy of epithelium and mesenchymal tissue, the benign tumors of epithelial and mesenchymal tissue, and vasogenic masses. ANOVA test and t test were used to compare the ADC values of different groups. The receiver operating characteristic curve (ROC) was constructed using various cut points of ADC for different parameters to confirm the diagnostic threshold value and evaluate the diagnostic efficacy. Results: All lesions were solitary. There were 22 malignant tumors, of which 6 lesions were hematolymphoid tumors and 16 lesions malignancy from epithelium and mesenchymal tissue. There were 45 benign tumors, of which 22 lesions were benign tumors from epithelium and mesenchymal tissue and 23 lesions vasogenic masses. The mean ADC value of malignant and benign masses was (0.88 ± 0.26) × 10 -3 mm 2 /s and (1.54 ± 0.41) × 10 -3 mm 2 /s respectively. There was statistically significant differences between them (t=6.897, P <0.01). The mean ADC value was(0.63 ± 0.10) × 10 -3 mm 2 /s in hematolymphoid tumors,(0.97 ±0.24) × 10 -3 mm 2 /s in malignancy from epithelium and mesenchymal tissue, (1.38 ± 0.23) × 10 -3 mm 2 /s in benign tumors from epithelium and mesenchymal tissue,(1.68 ± 0.49) × 10 -3 mm 2 /s in vasogenic masses respectively. There was statistically significant difference among all 4 groups(F=22.788, P<0.01), and the differences between any 2 groups were still statistically significant (P <0.05). The area under

  4. On a new procedure for determining the diffusion coefficients of swarm electrons

    International Nuclear Information System (INIS)

    Winkler, R.; Wilhelm, J.; Braglia, G.L.

    1985-01-01

    A new method for solving the Boltzmann kinetic equation applied to the determination of diffusion coefficients of swarm electrons in a model plasma, and CO 2 and N 2 plasmas is proposed. The method which uses Legendre polynomial expansion of the electron velocity distribution of the stationary and homogeneous plasma, is based upon an analytical isolation of the non-singular part of the general solution from the singular part. The converged values of the diffusion coefficients given by the new method are compared with the results of Monte-Carlo simulations. (D.Gy.)

  5. Estimation of water diffusion coefficient into polycarbonate at different temperatures using numerical simulation

    Energy Technology Data Exchange (ETDEWEB)

    Nasirabadi, P. Shojaee; Jabbari, M.; Hattel, J. H. [Process Modelling Group, Department of Mechanical Engineering, Technical University of Denmark, Nils Koppels Allé, 2800 Kgs. Lyngby (Denmark)

    2016-06-08

    Nowadays, many electronic systems are exposed to harsh conditions of relative humidity and temperature. Mass transport properties of electronic packaging materials are needed in order to investigate the influence of moisture and temperature on reliability of electronic devices. Polycarbonate (PC) is widely used in the electronics industry. Thus, in this work the water diffusion coefficient into PC is investigated. Furthermore, numerical methods used for estimation of the diffusion coefficient and their assumptions are discussed. 1D and 3D numerical solutions are compared and based on this, it is shown how the estimated value can be different depending on the choice of dimensionality in the model.

  6. LETTER TO THE EDITOR: Fractal diffusion coefficient from dynamical zeta functions

    Science.gov (United States)

    Cristadoro, Giampaolo

    2006-03-01

    Dynamical zeta functions provide a powerful method to analyse low-dimensional dynamical systems when the underlying symbolic dynamics is under control. On the other hand, even simple one-dimensional maps can show an intricate structure of the grammar rules that may lead to a non-smooth dependence of global observables on parameters changes. A paradigmatic example is the fractal diffusion coefficient arising in a simple piecewise linear one-dimensional map of the real line. Using the Baladi-Ruelle generalization of the Milnor-Thurnston kneading determinant, we provide the exact dynamical zeta function for such a map and compute the diffusion coefficient from its smallest zero.

  7. Estimating Outer Zone Radial Diffusion Coefficients from Drift Scale Fluctuations in Van Allen Particle Data

    Science.gov (United States)

    O'Brien, T. P., III; Claudepierre, S. G.

    2017-12-01

    During geomagnetic storms, the Earth's outer radiation belt experiences enhanced radial transport. This transport occurs via phase-dependent radial displacements of particles, either by impulsive events or drift resonant waves. Because transport is phase dependent, it produces drift phase bunching, which can be observed with in situ particle detectors. We provide bounds on the radial diffusion coefficients derived from this drift phase structure as seen by NASA's Van Allen Probes. We compare these bounds to published radial diffusion coefficient models, particularly those derived independently from electromagnetic field observations.

  8. Determination of diffusion coefficients in polypyrrole thin films using a current pulse relaxation method

    Science.gov (United States)

    Penner, Reginald M.; Vandyke, Leon S.; Martin, Charles R.

    1987-01-01

    The current pulse E sub oc relaxation method and its application to the determination of diffusion coefficients in electrochemically synthesized polypyrrole thin films is described. Diffusion coefficients for such films in Et4NBF4 and MeCN are determined for a series of submicron film thicknesses. Measurement of the double-layer capacitance, C sub dl, and the resistance, R sub u, of polypyrrole thin films as a function of potential obtained with the galvanostatic pulse method is reported. Measurements of the electrolyte concentration in reduced polypyrrole films are also presented to aid in the interpretation of the data.

  9. Estimation of Water Diffusion Coefficient into Polycarbonate at Different Temperatures Using Numerical Simulation

    DEFF Research Database (Denmark)

    Shojaee Nasirabadi, Parizad; Jabbaribehnam, Mirmasoud; Hattel, Jesper Henri

    2016-01-01

    ) is widely used in the electronics industry. Thus, in this work the water diffusion coefficient into PC is investigated. Furthermore, numerical methods used for estimation of the diffusion coefficient and their assumptions are discussed. 1D and 3D numerical solutions are compared and based on this, itis......Nowadays, many electronic systems are exposed to harsh conditions of relative humidity and temperature. Masstransport properties of electronic packaging materials are needed in order to investigate the influence of moisture andtemperature on reliability of electronic devices. Polycarbonate (PC...... shown how the estimated value can be different depending on the choice of dimensionality in the model....

  10. Determination of Concentration Dependent Diffusion Coefficients of Carbon in Expanded Austenite

    DEFF Research Database (Denmark)

    Hummelshøj, Thomas Strabo; Christiansen, Thomas; Somers, Marcel A. J.

    2008-01-01

    Abstract. In the present paper various experimental procedures to experimentally determine the concentration dependent diffusion coefficient of carbon in expanded austenite are evaluated. To this end thermogravimetric carburization was simulated for various experimental conditions and the evaluated...... composition dependent diffusivity of carbon derived from the simulated experiments was compared with the input data. The most promising procedure for an accurate determination is shown to be stepwise gaseous carburizing of thin foils in a gaseous atmosphere; the finer the stepsize, the more accurate...

  11. A method to measure the diffusion coefficient by neutron wave propagation for limited samples

    International Nuclear Information System (INIS)

    Woznicka, U.

    1986-03-01

    A study has been made of the use of the neutron wave and pulse propagation method for measurement of thermal neutron diffusion parameters. Earlier works an homogenous and heterogeneous media are reviewed. A new method is sketched for the determination of the diffusion coefficient for samples of limited size. The principle is to place a relatively thin slab of the material between two blocks of a medium with known properties. The advantages and disadvantages of the method are discussed. (author)

  12. Simultaneous inversion for the space-dependent diffusion coefficient and the fractional order in the time-fractional diffusion equation

    International Nuclear Information System (INIS)

    Li, Gongsheng; Zhang, Dali; Jia, Xianzheng; Yamamoto, Masahiro

    2013-01-01

    This paper deals with an inverse problem of simultaneously identifying the space-dependent diffusion coefficient and the fractional order in the 1D time-fractional diffusion equation with smooth initial functions by using boundary measurements. The uniqueness results for the inverse problem are proved on the basis of the inverse eigenvalue problem, and the Lipschitz continuity of the solution operator is established. A modified optimal perturbation algorithm with a regularization parameter chosen by a sigmoid-type function is put forward for the discretization of the minimization problem. Numerical inversions are performed for the diffusion coefficient taking on different functional forms and the additional data having random noise. Several factors which have important influences on the realization of the algorithm are discussed, including the approximate space of the diffusion coefficient, the regularization parameter and the initial iteration. The inversion solutions are good approximations to the exact solutions with stability and adaptivity demonstrating that the optimal perturbation algorithm with the sigmoid-type regularization parameter is efficient for the simultaneous inversion. (paper)

  13. Lie Symmetry of the Diffusive Lotka–Volterra System with Time-Dependent Coefficients

    Directory of Open Access Journals (Sweden)

    Vasyl’ Davydovych

    2018-02-01

    Full Text Available Lie symmetry classification of the diffusive Lotka–Volterra system with time-dependent coefficients in the case of a single space variable is studied. A set of such symmetries in an explicit form is constructed. A nontrivial ansatz reducing the Lotka–Volterra system with correctly-specified coefficients to the system of ordinary differential equations (ODEs and an example of the exact solution with a biological interpretation are found.

  14. The use of photon correlation spectroscopy method for determining diffusion coefficient in brine and herring flesh

    Directory of Open Access Journals (Sweden)

    Shumanova M.V.

    2015-03-01

    Full Text Available The process fish salting has been studied by the method of photon correlation spectroscopy; the distribution of salt concentration in the solution and herring flesh with skin has been found, diffusion coefficients and salt concentrations used for creating a mathematical model of the salting technology have been worked out; the possibility of determination by this method the coefficient of dynamic viscosity of solutions and different media (minced meat etc. has been considered

  15. Diffusion coefficient

    Indian Academy of Sciences (India)

    kbhattacharjee

    in bulk water becomes Au. 13 inside cell. Fluorescent Gold Nanocluster Inside a Human Breast Cell. Au. 25. Au. 13. Bulk water. Live cell. Emission energy = E f. / N1/3. Cancer. N = number of Au atoms in cluster ..... <λ/2. Super Resolution Microscopy: < λ/2. STED = Stimulated Emission Depletion (S. HELL). Strategy: two ...

  16. The effect of recombination and attachment on meteor radar diffusion coefficient profiles

    Science.gov (United States)

    Lee, C. S.; Younger, J. P.; Reid, I. M.; Kim, Y. H.; Kim, J.-H.

    2013-04-01

    Estimates of the ambipolar diffusion coefficient producedusing meteor radar echo decay times display an increasing trend below 80-85 km, which is inconsistent with a diffusion-only theory of the evolution of meteor trails. Data from the 33 MHz meteor radar at King Sejong Station, Antarctica, have been compared with observations from the Aura Earth Observing System Microwave Limb Sounder satellite instrument. It has been found that the height at which the diffusion coefficient gradient reverses follows the height of a constant neutral atmospheric density surface. Numerical simulations of meteor trail diffusion including dissociative recombination with atmospheric ions and three-body attachment of free electrons to neutral molecules indicate that three-body attachment is responsible for the distortion of meteor radar diffusion coefficient profiles at heights below 90 km, including the gradient reversal below 80-85 km. Further investigation has revealed that meteor trails with low initial electron line density produce decay times more consistent with a diffusion-only model of meteor trail evolution.

  17. An innovative method for determining the diffusion coefficient of product nuclide

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Chih Lung [Dept. of Nuclear Back-end Management, Taiwan Power Company, Taipei (China); Wang, Tsing Hai [Dept. Biomedical Engineering and Environment Sciences, National Tsing Hua University, Hsinchu (China)

    2017-08-15

    Diffusion is a crucial mechanism that regulates the migration of radioactive nuclides. In this study, an innovative numerical method was developed to simultaneously calculate the diffusion coefficient of both parent and, afterward, series daughter nuclides in a sequentially reactive through-diffusion model. Two constructed scenarios, a serial reaction (RN{sub 1} → RN{sub 2} → RN{sub 3}) and a parallel reaction (RN{sub 1} → RN{sub 2}A + RN{sub 2}B), were proposed and calculated for verification. First, the accuracy of the proposed three-member reaction equations was validated using several default numerical experiments. Second, by applying the validated numerical experimental concentration variation data, the as-determined diffusion coefficient of the product nuclide was observed to be identical to the default data. The results demonstrate the validity of the proposed method. The significance of the proposed numerical method will be particularly powerful in determining the diffusion coefficients of systems with extremely thin specimens, long periods of diffusion time, and parent nuclides with fast decay constants.

  18. Inverse method for determining radon diffusion coefficient and free radon production rate of fragmented uranium ore

    International Nuclear Information System (INIS)

    Ye, Yong-jun; Wang, Li-heng; Ding, De-xin; Zhao, Ya-li; Fan, Nan-bin

    2014-01-01

    The radon diffusion coefficient and the free radon production rate are important parameters for describing radon migration in the fragmented uranium ore. In order to determine the two parameters, the pure diffusion migration equation for radon was firstly established and its analytic solution with the two parameters to be determined was derived. Then, a self manufactured experimental column was used to simulate the pure diffusion of the radon, the improved scintillation cell method was used to measure the pore radon concentrations at different depths of the column loaded with the fragmented uranium ore, and the nonlinear least square algorithm was used to inversely determine the radon diffusion coefficient and the free radon production rate. Finally, the solution with the two inversely determined parameters was used to predict the pore radon concentrations at some depths of the column, and the predicted results were compared with the measured results. The results show that the predicted results are in good agreement with the measured results and the numerical inverse method is applicable to the determination of the radon diffusion coefficient and the free radon production rate for the fragmented uranium ore. - Highlights: • Inverse method for determining two transport parameters of radon is proposed. • A self-made experimental apparatus is used to simulate radon diffusion process. • Sampling volume and position for measuring radon concentration are optimized. • The inverse results of an experimental sample are verified

  19. Negative Correlation between the Diffusion Coefficient and Transcriptional Activity of the Glucocorticoid Receptor.

    Science.gov (United States)

    Mikuni, Shintaro; Yamamoto, Johtaro; Horio, Takashi; Kinjo, Masataka

    2017-08-25

    The glucocorticoid receptor (GR) is a transcription factor, which interacts with DNA and other cofactors to regulate gene transcription. Binding to other partners in the cell nucleus alters the diffusion properties of GR. Raster image correlation spectroscopy (RICS) was applied to quantitatively characterize the diffusion properties of EGFP labeled human GR (EGFP-hGR) and its mutants in the cell nucleus. RICS is an image correlation technique that evaluates the spatial distribution of the diffusion coefficient as a diffusion map. Interestingly, we observed that the averaged diffusion coefficient of EGFP-hGR strongly and negatively correlated with its transcriptional activities in comparison to that of EGFP-hGR wild type and mutants with various transcriptional activities. This result suggests that the decreasing of the diffusion coefficient of hGR was reflected in the high-affinity binding to DNA. Moreover, the hyper-phosphorylation of hGR can enhance the transcriptional activity by reduction of the interaction between the hGR and the nuclear corepressors.

  20. Usefulness of diffusion-weighted MRI in differentiating benign from malignant musculoskeletal tumors

    International Nuclear Information System (INIS)

    Nagata, Shuji; Uchida, Masafumi; Hayabuchi, Naofumi

    2005-01-01

    The purpose of this study was to evaluate the usefulness of diffusion-weighted MRI in distinguishing different components and in differentiating benign from malignant musculoskeletal tumors. Fifty-seven patients with musculoskeletal tumors underwent MR at our institution from October 1999 to April 2002. We evaluated 57 tumors (9 bone tumors and 48 soft tissue tumors). All tumors were classified into 8 groups (myxomatous, fibrous, cystic, cartilaginous, fatty components, hematomas, other benign tumors, and other malignant tumors). MR examinations were performed with a 1.5-Tesla system. Diffusion-weighted single-shot echo planer imaging (EPI) images were obtained in all patients. Apparent diffusion coefficients (ADCs) were calculated by using b factors of 0 and 1,000 sec/mm 2 . ADC values of myxomatous, cystic, and cartilaginous components were significantly higher than those of other tumors. In cartilaginous tumors, malignant tumor ADC values (2.33±0.44) were higher than those of benign tumors (2.13±0.13). However, there was no significant difference between benign and malignant tumors. Except for high-intensity components on T1-weighted imaging and low or homogeneously very high intensity components on T2-weighted imaging, there was a significant difference in ADC between malignant (1.35±0.40) and benign (1.97±0.50) tumors. Within the limited number of cases, there was a significant difference in ADC between malignant and benign tumors. (author)

  1. Diffusion-weighted echo-planar MRI of lacunar infarcts

    International Nuclear Information System (INIS)

    Noguchi, K.; Nagayoshi, T.; Watanabe, N.; Kanazawa, T.; Toyoshima, S.; Morijiri, M.; Shojaku, H.; Shimizu, M.; Seto, H.

    1998-01-01

    We studied 35 patients with lacunar infarcts, using diffusion-weighted echo-planar imaging (DW-EPI) at 1.5 T. The relative apparent diffusion coefficient ratio (ADCR) of each lesion was calculated and lesion conspicuity on DW-EPI was compared to that on images aquired with fast fluid-attenuated inversion recovery and T2-weighted fast spin-echo sequences. Acute small infarcts (within 3 days) were identified with DW-EPI as an area of decreased ADCR (range 0.33-0.87; mean 0.67) and high signal, subacute small infarcts (4-30 days) as a high-signal or isointense areas of decreased or nearly normal ADCR (0.54-0.98; 0.73), and chronic small infarcts (> 30 days) as low- or high-signal areas of nearly normal or increased ADCR (0.97-1.92; 1.32). In three patients, small infarcts of the brain stem in the hyperacute phase (within 6 h) were seen only with DW-EPI. In five patients, fresh small infarcts adjacent to multiple old infarcts could be distinguished only with DW-EPI. (orig.)

  2. Measurements of the Fe3+ diffusion coefficient in Fricke Xylenol gel using optical density measurements

    International Nuclear Information System (INIS)

    Nonato de Oliveira, Lucas; Sampaio, Francisco Glaildo Almeida; Moreira, Marcos Vasques; Almeida, Adelaide de

    2014-01-01

    In Fricke dosimetry, optical density measurements are performed some time after dosimeter irradiation. Values of the diffusion coefficient of Fe 3+ in Fricke Xylenol gel (FXG) are necessary for determining the spatial distribution of the absorbed dose from measurements of the optical density. Five sets of FXG dosimeters, kept at different constant temperatures, were exposed to collimated 6 MV photons. The optical density profile, proportional to the Fe 3+ concentration, at the boundary between irradiated and non-irradiated parts of each dosimeter was measured periodically over a period of 60 h. By comparing the experimental data with a function that accounts for the unobserved initial concentration profile of Fe 3+ in the FXG, we obtained diffusion coefficients 0.30±0.05, 0.40±0.05, 0.50±0.05, 0.60±0.05 and 0.80±0.05 mm 2 /h for the temperatures 283.0±0.5, 286.0±0.5, 289.0±0.5, 292.0±0.5, and 296.0±0.5 K, respectively. The activation energy of Fe 3+ diffusion in the gel, 0.54±0.06 eV, was determined from the temperature dependence of the diffusion coefficients. - Highlights: • A new analytical method to determine diffusion coefficients of ions in gels is proposed. • The method is applied for measurements of the diffusion coefficients of Fe 3+ ions in a Fricke gel dosimeter. • Activation energy of the Fe 3+ ions in the gel was found to be 0.54 ±0.06 eV

  3. The Role of Apparent Diffusion Coefficient Quantification in Differentiating Benign and Malignant Renal Masses by 3 Tesla Magnetic Resonance Imaging.

    Science.gov (United States)

    Göya, Cemil; Hamidi, Cihad; Bozkurt, Yaşar; Yavuz, Alpaslan; Kuday, Suzan; Gümüş, Hatice; Türkçü, Gül; Hattapoğlu, Salih; Bilici, Aslan

    2015-07-01

    Diffusion-weighted magnetic resonance imaging (DWI) is a widely-accepted diagnostic modality whose efficacy has been investigated by numerous past studies in the differentiation of malignant lesions from benign entities. The aim of this study was to evaluate the efficiency of diffusion-weighted magnetic resonance imaging in the characterization of renal lesions. Diagnostic accuracy study. A total of 137 patients with renal lesions were included in this study. The median apparent diffusion coefficient (ADC) values as well as the b 800 and b 1600 signal intensities of normal kidneys, solid components of mixed renal masses, and total cystic lesions were evaluated. There were significant differences between the ADC values of lesions and normal renal parenchyma, and between the ADC values of benign and malignant renal lesions on DWIs at b values of 800 and 1600 s/mm(2) (pbenign and malignant renal lesions. A cutoff value of 1.623 × 10(-3) mm(2)/s for the ADC with a b value of 1600 s/mm(2) provided 79% sensitivity and 96% specificity (pbenign and malignant renal lesions. Accurate assessment of renal masses is important for determining the necessity for surgical intervention. DWI provides additional value by differentiating benign from malignant renal tumors and can be added to routine kidney MRI protocols.

  4. Decreased apparent diffusion coefficient in the pituitary and correlation with hypopituitarism in patients with traumatic brain injury.

    Science.gov (United States)

    Zheng, Ping; He, Bin; Guo, Yijun; Zeng, Jingsong; Tong, Wusong

    2015-07-01

    The relationship between microstructural abnormality in patients with traumatic brain injury (TBI) and hormone-secreting status remains unknown. In this study, the authors aimed to identify the role of the apparent diffusion coefficient (ADC) using a diffusion-weighted imaging (DWI) technique and to evaluate the association of such changes with hypopituitarism in patients with TBI. Diffusion-weighted images were obtained in 164 consecutive patients with TBI within 2 weeks after injury to generate the pituitary ADC as a measure of microstructural change. Patients with TBI were further grouped into those with and those without hypopituitarism based on the secretion status of pituitary hormones at 6 months postinjury. Thirty healthy individuals were enrolled in the study and underwent MRI examinations for comparison. Mean ADC values were compared between this control group, the patients with TBI and hypopituitarism, and the patients with TBI without hypopituitarism; correlational studies were also performed. Neurological outcome was assessed with the Glasgow Outcome Scale (GOS) for all TBI patients 6 months postinjury. In the TBI group, 84 patients had hypopituitarism and 80 had normal pituitary function. The pituitary ADC in TBI patients was significantly less than that in controls (1.83 ± 0.16 vs 4.13 ± 0.33, p correlated with neurological outcome at 6 months following TBI (r = 0.602, p correlated with hormone-secreting status in TBI patients. The authors suggest that pituitary ADC may be a useful biomarker to predict pituitary function in patients with TBI.

  5. Monte Carlo Finite Volume Element Methods for the Convection-Diffusion Equation with a Random Diffusion Coefficient

    Directory of Open Access Journals (Sweden)

    Qian Zhang

    2014-01-01

    Full Text Available The paper presents a framework for the construction of Monte Carlo finite volume element method (MCFVEM for the convection-diffusion equation with a random diffusion coefficient, which is described as a random field. We first approximate the continuous stochastic field by a finite number of random variables via the Karhunen-Loève expansion and transform the initial stochastic problem into a deterministic one with a parameter in high dimensions. Then we generate independent identically distributed approximations of the solution by sampling the coefficient of the equation and employing finite volume element variational formulation. Finally the Monte Carlo (MC method is used to compute corresponding sample averages. Statistic error is estimated analytically and experimentally. A quasi-Monte Carlo (QMC technique with Sobol sequences is also used to accelerate convergence, and experiments indicate that it can improve the efficiency of the Monte Carlo method.

  6. Differentiation between benign and malignant breast lesions using quantitative diffusion-weighted sequence on 3 T MRI

    International Nuclear Information System (INIS)

    Tan, S.L.L.; Rahmat, K.; Rozalli, F.I.; Mohd-Shah, M.N.; Aziz, Y.F.A.; Yip, C.H.; Vijayananthan, A.; Ng, K.H.

    2014-01-01

    Aim: To investigate the capability and diagnostic accuracy of diffusion-weighted imaging (DWI) in differentiating benign from malignant breast lesions using 3 T magnetic resonance imaging (MRI). Materials and methods: Women with suspicious or indeterminate breast lesions detected at MRI, mammogram and/or ultrasound were recruited for dynamic contrast-enhanced (DCE)-MRI and DWI prior to their biopsy. Image fusion of DCE-MRI with apparent diffusion coefficient (ADC) map was utilized to select the region of interest (ROI) for ADC calculation in the area that showed the most avid enhancement. DWI was performed using two sets of b-values at 500 and 1000 s/mm 2 , respectively. Results: Fifty women were recruited and the final analysis comprised 44 breast lesions, 31 of which were malignant and 13 were benign. Significant results were obtained between ADC values of benign and malignant lesions (p −3 mm 2 /s for b = 500 s/mm 2 and 1.22 × 10 −3 mm 2 /s for b = 1000 s/mm 2 , respectively. The sensitivity of DCE-MRI alone was 100% with a specificity of 66.7%. When DCE-MRI was combined with b = 1000 s/mm 2 , the specificity rose to 100%, while only mildly affecting sensitivity (90.6%). No significant correlation was found between ADC values and prognostic factors, such as lymph node metastasis, tumour size, oestrogen receptor (ER), progesterone receptor (PR), and human epidermal growth factor receptor 2 (HER2) status, and tumour grades. Conclusion: The present study provides consistent evidence to support DWI as a diagnostic tool for breast lesion characterization. A combination of DCE-MRI with DWI is suggested to improve the sensitivity and specificity of lesion characterization

  7. Noninvasive photoacoustic measurement of absorption coefficient using internal light irradiation of cylindrical diffusing fiber

    Science.gov (United States)

    Peng, Dong-qing; Zhu, Li-li; Li, Zhi-fang; Li, Hui

    2017-09-01

    Absorption coefficient of biological tissue is an important parameter in biomedicine, but its determination remains a challenge. In this paper, we propose a method using focusing photoacoustic imaging technique and internal light irradiation of cylindrical diffusing fiber (CDF) to quantify the target optical absorption coefficient. Absorption coefficients for ink absorbers are firstly determined through photoacoustic and spectrophotometric measurements at the same excitation, which demonstrates the feasibility of this method. Also, the optical absorption coefficients of ink absorbers with several concentrations are measured. Finally, the two-dimensional scanning photoacoustic image is obtained. Optical absorption coefficient measurement and simultaneous photoacoustic imaging of absorber non-invasively are the typical characteristics of the method. This method can play a significant role for non-invasive determination of blood oxygen saturation, the absorption-based imaging and therapy.

  8. The diffusion coefficient for 239Pu, 241Am, 99Tc and 137Cs in highly compacted buffer materials

    International Nuclear Information System (INIS)

    Zhou Kanghan; Li Guoding

    1998-01-01

    Based on one-dimension diffusion model, the diffusion coefficients of Pu, Am, Tc and Cs in highly compacted sodium-bentonite generally used as buffer materials in geologic disposal system for high-level radioactive waste have been determined at room temperature in the atmosphere of nitrogen. The results show that the diffusion coefficients of Am, Pu and Tc and about 10 -13 ∼10 -15 m 2 /s, and that of Cs about 10 -12 m 2 /s. The diffusion coefficients of these elements decrease with the increasing of the dry density of buffer materials. From the relationship of diffusion coefficient, retardation coefficient and dry density of bentonite, it has been concluded that Am and Pu transfer predominately by diffusion in solid phase, however, Cs and Tc by diffusion in pore water

  9. Trapped-ion anomalous diffusion coefficient on the basis of single mode saturation

    International Nuclear Information System (INIS)

    Koshi, Yuji; Hatayama, Akiyoshi; Ogasawara, Masatada.

    1982-03-01

    Expressions of the anomalous diffusion coefficient due to the dissipative trapped ion instability (DTII) are derived for the case with and without the effect of magnetic shear. Derivation is made by taking into account of the single mode saturation of the DTII previously obtained numerically. In the absence of the shear effect, the diffusion coefficient is proportional to #betta#sub(i)a 2 (#betta#sub(i) is the effective collision frequency of the trapped ions and a is the minor radius of a torus) and is much larger than the neoclassical ion heat conductivity. In the presence of the shear effect, the diffusion coefficient is much smaller than the Kadomtsev and Pogutse's value and is the same order of magnitude as the neoclassical ion heat conductivity. Dependences of the diffusion coefficient on the temperature and on the total particle number density are rather complicated due to the additional spectral cut-off, which is introduced to regularize the short wavelength modes in the numerical analysis. (author)

  10. Calculation of calcium diffusion coefficient of cement hardenings using minute pore data

    International Nuclear Information System (INIS)

    Hitomi, Takashi; Takeda, Nobufumi; Iriya, Keishiro

    2009-01-01

    This report describes the calculations of the diffusion coefficient of the Ca ion of cement hardenings using minute pore data. The observed hardenings were ordinary Portland cement (OPC), low-heat Portland cement with fly ash (LPC+FA) and highly fly ash containing silica fume cement (HFSC). The samples were cured in the standard and artificially leached by accelerated test. Minute pore datas of the cement hardenings were acquired with image processing of internal structural information obtained from high resolution X-ray computed tomography observations. Upon analysis, several voxels are combined into one bigger voxel, the diffusion coefficient of the voxels were determined in proportion to the number of voxels which were included in. The results reveal that the change in the calcium diffusion coefficient of OPC due to leaching was large, but the LPC+FA and HFSC cements exhibited even greater changes than OPC. It is suggested that the diffusion coefficients are proportional to the Ca/Si ratio of the samples. (author)

  11. Diffusion Coefficients in Systems LDPE Plus Cyclohexane and LDPE Plus Benzene

    Czech Academy of Sciences Publication Activity Database

    Randová, A.; Bartovská, L.; Hovorka, Š.; Bartovský, T.; Poloncarzová, Magda; Friess, K.

    -, 068 (2010), s. 1-6 ISSN 1618-7229 R&D Projects: GA ČR GA104/08/0600 Institutional research plan: CEZ:AV0Z40720504 Keywords : swelling * diffusion coefficients * low density polyethylene Subject RIV: CI - Industrial Chemistry, Chemical Engineering Impact factor: 0.574, year: 2010

  12. Comparison of measured and satellite-derived spectral diffuse attenuation coefficients for the Arabian Sea

    Digital Repository Service at National Institute of Oceanography (India)

    Suresh, T.; Talaulikar, M.; Desa, E.; Matondkar, S.G.P.; Mascarenhas, A.

    The results of study comparing the spectral diffuse attenuation coefficients Kd(Lambda) measured in the Arabian Sea with those derived from the Sea-Viewing Wide Field-of-View Sensor (SeaWiFS) using three algorithms, of which two are empirical...

  13. New method and installation for rapid determination of radon diffusion coefficient in various materials

    International Nuclear Information System (INIS)

    Tsapalov, Andrey; Gulabyants, Loren; Livshits, Mihail; Kovler, Konstantin

    2014-01-01

    The mathematical apparatus and the experimental installation for the rapid determination of radon diffusion coefficient in various materials are developed. The single test lasts not longer than 18 h and allows testing numerous materials, such as gaseous and liquid media, as well as soil, concrete and radon-proof membranes, in which diffusion coefficient of radon may vary in an extremely wide range, from 1·10 −12 to 5·10 −5 m 2 /s. The uncertainty of radon diffusion coefficient estimation depends on the permeability of the sample and varies from about 5% (for the most permeable materials) to 40% (for less permeable materials, such as radon-proof membranes). - Highlights: • The new method and installation for determination of radon diffusion coefficient D are developed. • The measured D-values vary in an extremely wide range, from 5×10 -5 to 1×10 -12 m 2 /s. • The materials include water, air, soil, building materials and radon-proof membranes. • The duration of the single test does not exceed 18 hours. • The measurement uncertainty varies from 5% (in permeable materials) to 40% (in radon gas barriers)

  14. Determination of molecular diffusion coefficient in n-alkane binary mixtures: empirical correlations.

    Science.gov (United States)

    De Mezquia, D Alonso; Bou-Ali, M Mounir; Larrañaga, M; Madariaga, J A; Santamaría, C

    2012-03-08

    In this work we have measured the molecular diffusion coefficient of the n-alkane binary series nC(i)-nC(6), nC(i)-nC(10), and nC(i)-nC(12) at 298 K and 1 atm and a mass fraction of 0.5 by using the so-called sliding symmetric tubes technique. The results show that the diffusion coefficient at this concentration is proportional to the inverse viscosity of the mixture. In addition, we have also measured the diffusion coefficient of the systems nC(12)-nC(6), nC(12)-nC(7), and nC(12)-nC(8) as a function of concentration. From the data obtained, it is shown that the diffusion coefficient of the n-alkane binary mixtures at any concentration can be calculated from the molecular weight of the components and the dynamic viscosity of the corresponding mixture at 50% mass fraction.

  15. Computable error estimates for Monte Carlo finite element approximation of elliptic PDE with lognormal diffusion coefficients

    KAUST Repository

    Hall, Eric; Haakon, Hoel; Sandberg, Mattias; Szepessy, Anders; Tempone, Raul

    2016-01-01

    lognormal diffusion coefficients with H´ older regularity of order up to 1/2 a.s. This low regularity implies that the high frequency finite element approximation error (i.e. the error from frequencies larger than the mesh frequency) is not negligible

  16. Computational error estimates for Monte Carlo finite element approximation with log normal diffusion coefficients

    KAUST Repository

    Sandberg, Mattias

    2015-01-01

    log normal diffusion coefficients with H¨older regularity of order up to 1/2 a.s. This low regularity implies that the high frequency finite element approximation error (i.e. the error from frequencies larger than the mesh frequency) is not negligible

  17. Diffusion Coefficient in the Zinc Coating Shaped on the Surface of Cast Iron and Steel Alloys

    Directory of Open Access Journals (Sweden)

    Kopyciński D.

    2015-06-01

    Full Text Available The article presents the method to assess the diffusion coefficient D in the sub-layer of intermetallic phases formed during hot-dip galvanizing “Armco” iron and ductile cast iron EN-GJS-500-7. Hot-dip galvanizing is one of the most popular forms of long-term protection of Fe-C alloys against corrosion. The process for producing a protective layer of sufficient quality is closely related to diffusion of atoms of zinc and iron. The simulation consist in performed a hot-dip galvanizing in laboratory condition above Fe-C alloys, in the Department of Engineering of Cast Alloys and Composites. Galvanizing time ranged from 15 to 300 seconds. Then metallographic specimens were prepared, intermetallic layers were measured and diffusion coefficient (D were calculated. It was found that the diffusion coefficient obtained during hot-dip galvanizing “Armco” iron and zinc is about two orders of magnitude less than the coefficient obtained on ductile cast iron EN-GJS-500-7.

  18. Diffusion coefficients for periodically induced multi-step persistent walks on regular lattices

    International Nuclear Information System (INIS)

    Gilbert, Thomas; Sanders, David P

    2012-01-01

    We present a generalization of our formalism for the computation of diffusion coefficients of multi-step persistent random walks on regular lattices to walks which include zero-displacement states. This situation is especially relevant to systems where tracer particles move across potential barriers as a result of the action of a periodic forcing whose period sets the timescale between transitions. (paper)

  19. A rotational diffusion coefficient of the 70s ribosome determined by depolarized laser light scattering

    NARCIS (Netherlands)

    Bruining, J.; Fijnaut, H.M.

    We have obtained a rotational diffusion coefficient of the 70S ribosome isolated from Escherichia-coli (MRE-600), from the depolarized light scattering spectrum measured by photon correlation spectroscopy. The intensity correlation function of depolarized scattered light contains contributions due

  20. Diffusion coefficients of Co, CO2, N20, and N2 in ethanol and toluene

    NARCIS (Netherlands)

    Snijder, E.D.; Snijder, E.D.; te Riele, M.J.M.; van Swaaij, Willibrordus Petrus Maria; Versteeg, Geert

    1995-01-01

    The Taylor dispersion technique was applied for the measurement of diffusion coefficients of dissolved gases in ethanol and toluene. Experiments with the system COz in H20 have been made to evaluate the accuracy of the method. The experimental procedure as described provides a fast and highly

  1. Unified derivation of the various definitions of lattice cell diffusion coefficients

    International Nuclear Information System (INIS)

    Hughes, R.P.

    1978-01-01

    The various definitions of lattice cell diffusion coefficients are discussed within the context of a one-dimensional slab lattice in one energy group. It is shown how each definition, although originally derived in its own particular way, can be derived from a single approach. This makes clear the differences between, and the advantages of, the various definitions

  2. Novel Technique for Direct Measurement of the Plasma Diffusion Coefficient in Magnetized Plasma

    Czech Academy of Sciences Publication Activity Database

    Brotánková, Jana; Martines, E.; Adámek, Jiří; Stöckel, Jan; Popa, G.; Costin, C.; Ionita, G.; Schrittwieser, R.; Van Oost, G.

    2008-01-01

    Roč. 48, 5-7 (2008), s. 418-423 ISSN 0863-1042. [International Workshop on Electrical Probes in Magnetized Plasmas/7th./. Praha, 22.07.2007-25.07.2007] Institutional research plan: CEZ:AV0Z20430508 Keywords : Tokamak * probe diagnostics * diffusion coefficient Subject RIV: BL - Plasma and Gas Discharge Physics Impact factor: 1.250, year: 2008

  3. Accurate determination of the diffusion coefficient of proteins by Fourier analysis with whole column imaging detection.

    Science.gov (United States)

    Zarabadi, Atefeh S; Pawliszyn, Janusz

    2015-02-17

    Analysis in the frequency domain is considered a powerful tool to elicit precise information from spectroscopic signals. In this study, the Fourier transformation technique is employed to determine the diffusion coefficient (D) of a number of proteins in the frequency domain. Analytical approaches are investigated for determination of D from both experimental and data treatment viewpoints. The diffusion process is modeled to calculate diffusion coefficients based on the Fourier transformation solution to Fick's law equation, and its results are compared to time domain results. The simulations characterize optimum spatial and temporal conditions and demonstrate the noise tolerance of the method. The proposed model is validated by its application for the electropherograms from the diffusion path of a set of proteins. Real-time dynamic scanning is conducted to monitor dispersion by employing whole column imaging detection technology in combination with capillary isoelectric focusing (CIEF) and the imaging plug flow (iPF) experiment. These experimental techniques provide different peak shapes, which are utilized to demonstrate the Fourier transformation ability in extracting diffusion coefficients out of irregular shape signals. Experimental results confirmed that the Fourier transformation procedure substantially enhanced the accuracy of the determined values compared to those obtained in the time domain.

  4. Measurement of molecular diffusion coefficients of carbon dioxide and methane in heavy oil

    Energy Technology Data Exchange (ETDEWEB)

    Gu, Y.; Tharanivasan, A.K.; Yang, C. [Regina Univ., SK (Canada)

    2004-07-01

    Vapour extraction (VAPEX) is a solvent-based thermal recovery process which is considered to be a viable process for recovering heavy oil. In order to develop a solvent-based enhanced oil recovery (EOR) operation, it is necessary to know the rate and extent of oil mobilization by the solvent. The molecular diffusion coefficient of solvent gas in heavy oil must be known. In this study, the pressure decay method was used to measure the molecular diffusivity of a gas solvent in heavy oil by monitoring the decaying pressure. The pressure decay method is a non-intrusive method in which physical contact is made between the gas solvent and the heavy oil. The pressure versus time data are measured until the heavy oil reaches complete saturation. The diffusion coefficient can be determined from the measured data and a mathematical model. In this study, the molecular diffusion coefficients of carbon dioxide-heavy oil and methane-heavy oil systems were measured and compared. The experiments were performed in closed high-pressure cells at constant reservoir temperature. An analytical solution was also obtained to predict the pressure in the gas phase and for the boundary conditions at the solvent-heavy oil interface for each solvent. Solvent diffusivity was determined by finding the best match of the numerically predicted and experimentally measured pressures.

  5. Acquisition, estimation, and interpretation of diffusion- and relaxation-based cerebral MRI contrasts

    NARCIS (Netherlands)

    Rudrapatna, U.S.

    2013-01-01

    From the past few years, Magnetic Resonance Imaging has significantly enhanced our understanding of brain structure and function. In particular, developments in Diffusion MRI are providing unique contrast mechanisms heretofore unavailable from other imaging modalities. Although predominantly used

  6. Calculation of the mutual diffusion coefficient by equilibrium and nonequilibrium molecular dynamics

    International Nuclear Information System (INIS)

    Erpenbeck, J.J.; Kincaid, J.M.

    1985-01-01

    A nonequilibrium molecular dynamics method for the calculation of the mutual diffusion coefficient for a mixture of hard spheres is described. The method is applied to a 50-50 mixture of equidiameter particles having a mass ratio of 0.1 for the two species, at a volume of three times close-packing. By extrapolating the results to the limit of vanishing concentration gradient and infinite system size, we obtain a value in statistical agreement with the result obtained using a Green-Kubo molecular dynamics procedure which is also described. The nonequilibrium calculation yields a mutual diffusion coefficient which decreases slightly with increasing concentration gradient. The Green-Kubo time correlation function for mutual diffusion displays a slow decay with time, qualitatively similar to the long-time tail which has been predicted by the hydrodynamic theory of Pomeau

  7. Calculation of the mutual diffusion coefficient by equilibrium and nonequilibrium molecular dynamics

    International Nuclear Information System (INIS)

    Erpenbeck, J.J.; Kincaid, J.M.

    1986-01-01

    A nonequilibrium molecular dynamics method for the calculation of the mutual diffusion coefficient for a mixture of hard spheres is described. The method is applied to a 50-50 mixture of equidiameter particles having a mass ratio of 0.1 for the two species, at a volume of three times close-packing. By extrapolating the results to the limit of vanishing concentration gradient and infinite system size, we obtain a value in statistical agreement with the result obtained using a Green-Kubo molecular dynamics procedure, which is also described. The nonequilibrium calculation yields a mutual diffusion coefficient which decreases slightly with increasing concentration gradient. The Green-Kubo timecorrelation function for mutual diffusion displays a slow decay with time, qualitatively similar to the long-time tail which has been predicted by the hydrodynamic theory of Pomeau

  8. Diffusion weighted imaging of the normal breast: reproducibility of apparent diffusion coefficient measurements and variation with menstrual cycle and menopausal status

    International Nuclear Information System (INIS)

    O'Flynn, Elizabeth A.M.; Morgan, Veronica A.; Giles, Sharon L.; de Souza, Nandita M.

    2012-01-01

    To establish the reproducibility of apparent diffusion coefficient (ADC) measurements in normal fibroglandular breast tissue and to assess variation in ADC values with phase of the menstrual cycle and menopausal status. Thirty-one volunteers (13 premenopausal, 18 postmenopausal) underwent magnetic resonance twice (interval 11-22 days) using diffusion-weighted MRI. ADC total and a perfusion-insensitive ADC high (omitting b = 0) were calculated. Reproducibility and inter-observer variability of mean ADC values were assessed. The difference in mean ADC values between the two phases of the menstrual cycle and the postmenopausal breast were evaluated. ADC total and ADC high showed good reproducibility (r% = 17.6, 22.4). ADC high showed very good inter-observer agreement (kappa = 0.83). The intraclass correlation coefficients (ICC) were 0.93 and 0.91. Mean ADC values were significantly lower in the postmenopausal breast (ADC total 1.46 ± 0.3 x 10 -3 mm 2 /s, ADC high 1.33 ± 0.3 x 10 -3 mm 2 /s) compared with the premenopausal breast (ADC total 1.84 ± 0.26 x 10 -3 mm 2 /s, ADC high 1.77 ± 0.26 x 10 -3 mm 2 /s; both P total P = 0.2, ADC high P = 0.24) or between postmenopausal women taking or not taking oestrogen supplements (ADC total P = 0.6, ADC high P = 0.46). ADC values in fibroglandular breast tissue are reproducible. Lower ADC values within the postmenopausal breast may reduce diffusion-weighted contrast and have implications for accurately detecting tumours. (orig.)

  9. Diffusion weighted imaging of the normal breast: reproducibility of apparent diffusion coefficient measurements and variation with menstrual cycle and menopausal status

    Energy Technology Data Exchange (ETDEWEB)

    O' Flynn, Elizabeth A.M.; Morgan, Veronica A.; Giles, Sharon L. [Cancer Research UK and ESPSRC Cancer Imaging Centre, Clinical Magnetic Resonance Group, Surrey (United Kingdom); deSouza, Nandita M. [Royal Marsden NHS Foundation Trust, Clinical Magnetic Resonance Group, Institute of Cancer Research, Surrey (United Kingdom)

    2012-07-15

    To establish the reproducibility of apparent diffusion coefficient (ADC) measurements in normal fibroglandular breast tissue and to assess variation in ADC values with phase of the menstrual cycle and menopausal status. Thirty-one volunteers (13 premenopausal, 18 postmenopausal) underwent magnetic resonance twice (interval 11-22 days) using diffusion-weighted MRI. ADC{sub total} and a perfusion-insensitive ADC{sub high} (omitting b = 0) were calculated. Reproducibility and inter-observer variability of mean ADC values were assessed. The difference in mean ADC values between the two phases of the menstrual cycle and the postmenopausal breast were evaluated. ADC{sub total} and ADC{sub high} showed good reproducibility (r% = 17.6, 22.4). ADC{sub high} showed very good inter-observer agreement (kappa = 0.83). The intraclass correlation coefficients (ICC) were 0.93 and 0.91. Mean ADC values were significantly lower in the postmenopausal breast (ADC{sub total} 1.46 {+-} 0.3 x 10{sup -3} mm{sup 2}/s, ADC{sub high} 1.33 {+-} 0.3 x 10{sup -3} mm{sup 2}/s) compared with the premenopausal breast (ADC{sub total} 1.84 {+-} 0.26 x 10{sup -3} mm{sup 2}/s, ADC{sub high} 1.77 {+-} 0.26 x 10{sup -3} mm{sup 2}/s; both P < 0.001). No significant difference was seen in ADC values in relation to menstrual cycle (ADC{sub total} P = 0.2, ADC{sub high} P = 0.24) or between postmenopausal women taking or not taking oestrogen supplements (ADC{sub total} P = 0.6, ADC{sub high} P = 0.46). ADC values in fibroglandular breast tissue are reproducible. Lower ADC values within the postmenopausal breast may reduce diffusion-weighted contrast and have implications for accurately detecting tumours. (orig.)

  10. Determination of uranyl nitrate diffusion coefficients in organic and aqueous media using the porous diaphragm method

    International Nuclear Information System (INIS)

    Chierice, G.O.

    1974-01-01

    The diffusion coefficient is one of the parameters necessary for the obtention of the extraction exponential coefficients, that are contained within the H.T.U. (height of transfer unity) calculation expression, when operating with continuous organic phase. The organic phase used was tri-n-butyl-phosphate (TBP) and varsol in the 35% and 65% proportions respectively. After each experiment, the uranium content present in each compartment was spectrophotometrically determined and the quantities contained in the aqueous phases were determined by means of volumetric titration. It was found out that the uranyl ion diffusion coefficient is two and one half times less in organic phase, this just being attributed to the greater interactions of the uranyl ions in organic than in aqueous medium

  11. Generalized Einstein relation for the mutual diffusion coefficient of a binary fluid mixture.

    Science.gov (United States)

    Felderhof, B U

    2017-08-21

    The method employed by Einstein to derive his famous relation between the diffusion coefficient and the friction coefficient of a Brownian particle is used to derive a generalized Einstein relation for the mutual diffusion coefficient of a binary fluid mixture. The expression is compared with the one derived by de Groot and Mazur from irreversible thermodynamics and later by Batchelor for a Brownian suspension. A different result was derived by several other workers in irreversible thermodynamics. For a nearly incompressible solution, the generalized Einstein relation agrees with the expression derived by de Groot and Mazur. The two expressions also agree to first order in solute density. For a Brownian suspension, the result derived from the generalized Smoluchowski equation agrees with both expressions.

  12. Calculation and analysis of the mobility and diffusion coefficient of thermal electrons in methane/air premixed flames

    KAUST Repository

    Bisetti, Fabrizio; El Morsli, Mbark

    2012-01-01

    Simulations of ion and electron transport in flames routinely adopt plasma fluid models, which require transport coefficients to compute the mass flux of charged species. In this work, the mobility and diffusion coefficient of thermal electrons

  13. Evaluation of Systematic and Random Error in the Measurement of Equilibrium Solubility and Diffusion Coefficient for Liquids in Polymers

    National Research Council Canada - National Science Library

    Shuely, Wendel

    2001-01-01

    A standardized thermogravimetric analyzer (TGA) desorption method for measuring the equilibrium solubility and diffusion coefficient of toxic contaminants with polymers was further developed and evaluated...

  14. Incremental value of diffusion weighted and dynamic contrast enhanced MRI in the detection of locally recurrent prostate cancer after radiation treatment: preliminary results

    International Nuclear Information System (INIS)

    Akin, Oguz; Vargas, Hebert Alberto; Hricak, Hedvig; Gultekin, David H.; Zheng, Junting; Moskowitz, Chaya; Pei, Xin; Sperling, Dahlia; Zelefsky, Michael J.; Schwartz, Lawrence H.

    2011-01-01

    To assess the incremental value of diffusion-weighted (DW-MRI) and dynamic contrast-enhanced MRI (DCE-MRI) to T2-weighted MRI (T2WI) in detecting locally recurrent prostate cancer after radiotherapy. Twenty-four patients (median age, 70 years) with a history of radiotherapy-treated prostate cancer underwent multi-parametric MRI (MP-MRI) and transrectal prostate biopsy. Two readers independently scored the likelihood of cancer on a 1-5 scale, using T2WI alone and then adding DW-MRI and DCE-MRI. Areas under receiver operating characteristic curves (AUCs) were estimated at the patient and prostate-side levels. The apparent diffusion coefficient (ADC) from DW-MRI and the K trans , k ep , v e , AUGC90 and AUGC180 from DCE-MRI were recorded. Biopsy was positive in 16/24 (67%) and negative in 8/24 (33%) patients. AUCs for readers 1 and 2 increased from 0.64 and 0.53 to 0.95 and 0.86 with MP-MRI, at the patient level, and from 0.73 and 0.66 to 0.90 and 0.79 with MP-MRI, at the prostate-side level (p values -3 mm 2 /s)], median K trans [1.07 vs. 0.34 (1/min)], and k ep [2.06 vs 1.0 (1/min)] (p values < 0.05). MP-MRI was significantly more accurate than T2WI alone in detecting locally recurrent prostate cancer after radiotherapy. (orig.)

  15. Incremental value of diffusion weighted and dynamic contrast enhanced MRI in the detection of locally recurrent prostate cancer after radiation treatment: preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Akin, Oguz; Vargas, Hebert Alberto; Hricak, Hedvig [Memorial Sloan-Kettering Cancer Center, Department of Radiology, New York, NY (United States); Gultekin, David H. [Memorial Sloan-Kettering Cancer Center, Medical Physics, New York, NY (United States); Zheng, Junting; Moskowitz, Chaya [Memorial Sloan-Kettering Cancer Center, Epidemiology and Biostatistics, New York, NY (United States); Pei, Xin; Sperling, Dahlia; Zelefsky, Michael J. [Memorial Sloan-Kettering Cancer Center, Radiation Oncology, New York, NY (United States); Schwartz, Lawrence H. [Columbia University College of Physicians and Surgeons, Radiology, New York, NY (United States)

    2011-09-15

    To assess the incremental value of diffusion-weighted (DW-MRI) and dynamic contrast-enhanced MRI (DCE-MRI) to T2-weighted MRI (T2WI) in detecting locally recurrent prostate cancer after radiotherapy. Twenty-four patients (median age, 70 years) with a history of radiotherapy-treated prostate cancer underwent multi-parametric MRI (MP-MRI) and transrectal prostate biopsy. Two readers independently scored the likelihood of cancer on a 1-5 scale, using T2WI alone and then adding DW-MRI and DCE-MRI. Areas under receiver operating characteristic curves (AUCs) were estimated at the patient and prostate-side levels. The apparent diffusion coefficient (ADC) from DW-MRI and the K{sup trans}, k{sub ep}, v{sub e}, AUGC90 and AUGC180 from DCE-MRI were recorded. Biopsy was positive in 16/24 (67%) and negative in 8/24 (33%) patients. AUCs for readers 1 and 2 increased from 0.64 and 0.53 to 0.95 and 0.86 with MP-MRI, at the patient level, and from 0.73 and 0.66 to 0.90 and 0.79 with MP-MRI, at the prostate-side level (p values < 0.05). Biopsy-positive and biopsy-negative prostate sides differed significantly in median ADC [1.44 vs. 1.68 (x 10{sup -3} mm{sup 2}/s)], median K{sup trans} [1.07 vs. 0.34 (1/min)], and k{sub ep} [2.06 vs 1.0 (1/min)] (p values < 0.05). MP-MRI was significantly more accurate than T2WI alone in detecting locally recurrent prostate cancer after radiotherapy. (orig.)

  16. Apparent diffusion coefficient measurement in glioma: Influence of region-of-interest determination methods on apparent diffusion coefficient values, interobserver variability, time efficiency, and diagnostic ability.

    Science.gov (United States)

    Han, Xu; Suo, Shiteng; Sun, Yawen; Zu, Jinyan; Qu, Jianxun; Zhou, Yan; Chen, Zengai; Xu, Jianrong

    2017-03-01

    To compare four methods of region-of-interest (ROI) placement for apparent diffusion coefficient (ADC) measurements in distinguishing low-grade gliomas (LGGs) from high-grade gliomas (HGGs). Two independent readers measured ADC parameters using four ROI methods (single-slice [single-round, five-round and freehand] and whole-volume) on 43 patients (20 LGGs, 23 HGGs) who had undergone 3.0 Tesla diffusion-weighted imaging and time required for each method of ADC measurements was recorded. Intraclass correlation coefficients (ICCs) were used to assess interobserver variability of ADC measurements. Mean and minimum ADC values and time required were compared using paired Student's t-tests. All ADC parameters (mean/minimum ADC values of three single-slice methods, mean/minimum/standard deviation/skewness/kurtosis/the10 th and 25 th percentiles/median/maximum of whole-volume method) were correlated with tumor grade (low versus high) by unpaired Student's t-tests. Discriminative ability was determined by receiver operating characteristic curves. All ADC measurements except minimum, skewness, and kurtosis of whole-volume ROI differed significantly between LGGs and HGGs (all P determination methods. Whole-volume histogram analysis did not yield better results than single-slice methods and took longer. Mean ADC value derived from single-round ROI is the most optimal parameter for differentiating LGGs from HGGs. 3 J. Magn. Reson. Imaging 2017;45:722-730. © 2016 International Society for Magnetic Resonance in Medicine.

  17. Evaporation Kinetics of Polyol Droplets: Determination of Evaporation Coefficients and Diffusion Constants

    Science.gov (United States)

    Su, Yong-Yang; Marsh, Aleksandra; Haddrell, Allen E.; Li, Zhi-Ming; Reid, Jonathan P.

    2017-11-01

    In order to quantify the kinetics of mass transfer between the gas and condensed phases in aerosol, physicochemical properties of the gas and condensed phases and kinetic parameters (mass/thermal accommodation coefficients) are crucial for estimating mass fluxes over a wide size range from the free molecule to continuum regimes. In this study, we report measurements of the evaporation kinetics of droplets of 1-butanol, ethylene glycol (EG), diethylene glycol (DEG), and glycerol under well-controlled conditions (gas flow rates and temperature) using the previously developed cylindrical electrode electrodynamic balance technique. Measurements are compared with a model that captures the heat and mass transfer occurring at the evaporating droplet surface. The aim of these measurements is to clarify the discrepancy in the reported values of mass accommodation coefficient (αM, equals to evaporation coefficient based on microscopic reversibility) for 1-butanol, EG, and DEG and improve the accuracy of the value of the diffusion coefficient for glycerol in gaseous nitrogen. The uncertainties in the thermophysical and experimental parameters are carefully assessed, the literature values of the vapor pressures of these components are evaluated, and the plausible ranges of the evaporation coefficients for 1-butanol, EG, and DEG as well as uncertainty in diffusion coefficient for glycerol are reported. Results show that αM should be greater than 0.4, 0.2, and 0.4 for EG, DEG, and 1-butanol, respectively. The refined values are helpful for accurate prediction of the evaporation/condensation rates.

  18. Theory of the diffusion coefficient of neutrons in a lattice containing cavities; Theorie du coefficient de diffusion des neutrons dans un reseau comportant des cavites

    Energy Technology Data Exchange (ETDEWEB)

    Benoist, P [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1964-01-15

    In an previous publication, a simple and general formulation of the diffusion coefficient, which defines the mode of weighting of the mean free paths of the various media, in introducing the collision probabilities in each medium, was established. This expression is demonstrated again here through a more direct method, and the velocity is introduced; new terms are emphasised, the existence of which implies that the representation of the diffusion area as the mean square of the straight line distance from source to absorption is not correct in a lattice. However these terms are of small enough an order of magnitude to he treated as a correction. The general expression also shows the existence, for the radial coefficient, of the series of angular correlation terms, which is seen to converge very slowly for large channels. The term by term computation which was initiated in the first work was then interrupted and a global formulation, which emphasize a resemblance with the problem of the thermal utilisation factor, was adopted. An integral method, analogous to that use for the computation of this factor, gives the possibility to establish new and simple practical formulae, which require the use of a few basic functions only. These formulae are very accurate, as seen from the results of a variational method which was studied as a reference. Various correction effects are reviewed. Expressions which allow the exact treatment of fuel rod clusters are presented. The theory is confronted with various experimental results, and a new method of measuring the radial coefficient is proposed. (author) [French] Dans une publication anterieure, on a etablie une formulation simple et generale du coefficient de diffusion, qui definit le mode de ponderation des libres parcours des differents milieux constituants en faisant apparaitre les probabilites de collision dans chaque milieu. On redemontre ici cette expression d'une maniere plus directe, tout en introduisant la variable

  19. Theory of the diffusion coefficient of neutrons in a lattice containing cavities; Theorie du coefficient de diffusion des neutrons dans un reseau comportant des cavites

    Energy Technology Data Exchange (ETDEWEB)

    Benoist, P. [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1964-01-15

    In an previous publication, a simple and general formulation of the diffusion coefficient, which defines the mode of weighting of the mean free paths of the various media, in introducing the collision probabilities in each medium, was established. This expression is demonstrated again here through a more direct method, and the velocity is introduced; new terms are emphasised, the existence of which implies that the representation of the diffusion area as the mean square of the straight line distance from source to absorption is not correct in a lattice. However these terms are of small enough an order of magnitude to he treated as a correction. The general expression also shows the existence, for the radial coefficient, of the series of angular correlation terms, which is seen to converge very slowly for large channels. The term by term computation which was initiated in the first work was then interrupted and a global formulation, which emphasize a resemblance with the problem of the thermal utilisation factor, was adopted. An integral method, analogous to that use for the computation of this factor, gives the possibility to establish new and simple practical formulae, which require the use of a few basic functions only. These formulae are very accurate, as seen from the results of a variational method which was studied as a reference. Various correction effects are reviewed. Expressions which allow the exact treatment of fuel rod clusters are presented. The theory is confronted with various experimental results, and a new method of measuring the radial coefficient is proposed. (author) [French] Dans une publication anterieure, on a etablie une formulation simple et generale du coefficient de diffusion, qui definit le mode de ponderation des libres parcours des differents milieux constituants en faisant apparaitre les probabilites de collision dans chaque milieu. On redemontre ici cette expression d'une maniere plus directe, tout en introduisant la variable

  20. Assessment of early treatment response to neoadjuvant chemotherapy in breast cancer using non-mono-exponential diffusion models: a feasibility study comparing the baseline and mid-treatment MRI examinations

    Energy Technology Data Exchange (ETDEWEB)

    Bedair, Reem; Manavaki, Roido; Gill, Andrew B.; Abeyakoon, Oshaani; Gilbert, Fiona J. [University of Cambridge, Department of Radiology, School of Clinical Medicine, Cambridge (United Kingdom); Priest, Andrew N.; Patterson, Andrew J. [Cambridge University Hospitals NHS Foundation Trust, Department of Radiology, Addenbrookes Hospital, Cambridge (United Kingdom); McLean, Mary A. [Cambridge University Hospitals NHS Foundation Trust, Department of Radiology, Addenbrookes Hospital, Cambridge (United Kingdom); University of Cambridge, Li Ka Shing Centre, Cancer Research UK Cambridge Institute, Cambridge (United Kingdom); Graves, Martin J. [University of Cambridge, Department of Radiology, School of Clinical Medicine, Cambridge (United Kingdom); Cambridge University Hospitals NHS Foundation Trust, Department of Radiology, Addenbrookes Hospital, Cambridge (United Kingdom); Griffiths, John R. [University of Cambridge, Li Ka Shing Centre, Cancer Research UK Cambridge Institute, Cambridge (United Kingdom)

    2017-07-15

    To assess the feasibility of the mono-exponential, bi-exponential and stretched-exponential models in evaluating response of breast tumours to neoadjuvant chemotherapy (NACT) at 3 T. Thirty-six female patients (median age 53, range 32-75 years) with invasive breast cancer undergoing NACT were enrolled for diffusion-weighted MRI (DW-MRI) prior to the start of treatment. For assessment of early response, changes in parameters were evaluated on mid-treatment MRI in 22 patients. DW-MRI was performed using eight b values (0, 30, 60, 90, 120, 300, 600, 900 s/mm{sup 2}). Apparent diffusion coefficient (ADC), tissue diffusion coefficient (D{sub t}), vascular fraction (Florin), distributed diffusion coefficient (DDC) and alpha (α) parameters were derived. Then t tests compared the baseline and changes in parameters between response groups. Repeatability was assessed at inter- and intraobserver levels. All patients underwent baseline MRI whereas 22 lesions were available at mid-treatment. At pretreatment, mean diffusion coefficients demonstrated significant differences between groups (p < 0.05). At mid-treatment, percentage increase in ADC and DDC showed significant differences between responders (49 % and 43 %) and non-responders (21 % and 32 %) (p = 0.03, p = 0.04). Overall, stretched-exponential parameters showed excellent repeatability. DW-MRI is sensitive to baseline and early treatment changes in breast cancer using non-mono-exponential models, and the stretched-exponential model can potentially monitor such changes. (orig.)

  1. Assessment of early treatment response to neoadjuvant chemotherapy in breast cancer using non-mono-exponential diffusion models: a feasibility study comparing the baseline and mid-treatment MRI examinations

    International Nuclear Information System (INIS)

    Bedair, Reem; Manavaki, Roido; Gill, Andrew B.; Abeyakoon, Oshaani; Gilbert, Fiona J.; Priest, Andrew N.; Patterson, Andrew J.; McLean, Mary A.; Graves, Martin J.; Griffiths, John R.

    2017-01-01

    To assess the feasibility of the mono-exponential, bi-exponential and stretched-exponential models in evaluating response of breast tumours to neoadjuvant chemotherapy (NACT) at 3 T. Thirty-six female patients (median age 53, range 32-75 years) with invasive breast cancer undergoing NACT were enrolled for diffusion-weighted MRI (DW-MRI) prior to the start of treatment. For assessment of early response, changes in parameters were evaluated on mid-treatment MRI in 22 patients. DW-MRI was performed using eight b values (0, 30, 60, 90, 120, 300, 600, 900 s/mm"2). Apparent diffusion coefficient (ADC), tissue diffusion coefficient (D_t), vascular fraction (Florin), distributed diffusion coefficient (DDC) and alpha (α) parameters were derived. Then t tests compared the baseline and changes in parameters between response groups. Repeatability was assessed at inter- and intraobserver levels. All patients underwent baseline MRI whereas 22 lesions were available at mid-treatment. At pretreatment, mean diffusion coefficients demonstrated significant differences between groups (p < 0.05). At mid-treatment, percentage increase in ADC and DDC showed significant differences between responders (49 % and 43 %) and non-responders (21 % and 32 %) (p = 0.03, p = 0.04). Overall, stretched-exponential parameters showed excellent repeatability. DW-MRI is sensitive to baseline and early treatment changes in breast cancer using non-mono-exponential models, and the stretched-exponential model can potentially monitor such changes. (orig.)

  2. Diffusion-controlled reaction. V. Effect of concentration-dependent diffusion coefficient on reaction rate in graft polymerization

    International Nuclear Information System (INIS)

    Imre, K.; Odian, G.

    1979-01-01

    The effect of diffusion on radiation-initiated graft polymerization has been studied with emphasis on the single- and two-penetrant cases. When the physical properties of the penetrants are similar, the two-penetrant problems can be reduced to the single-penetrant problem by redefining the characteristic parameters of the system. The diffusion-free graft polymerization rate is assumed to be proportional to the upsilon power of the monomer concentration respectively, and, in which the proportionality constant a = k/sub p/R/sub i//sup w//k/sub t//sup z/, where k/sub p/ and k/sub t/ are the propagation and termination rate constants, respectively, and R/sub i/ is the initiation rate. The values of upsilon, w, and z depend on the particular reaction system. The results of earlier work were generalized by allowing a non-Fickian diffusion rate which predicts an essentially exponential dependence on the monomer concentration of the diffusion coefficient, D = D 0 [exp(deltaC/M)], where M is the saturation concentration. A reaction system is characterized by the three dimensionless parameters, upsilon, delta, and A = (L/2)[aM/sup (upsilon--1)//D 0 ]/sup 1/2/, where L is the polymer film thickness. Graft polymerization tends to become diffusion controlled as A increases. Larger values of delta and ν cause a reaction system to behave closer to the diffusion-free regime. Transition from diffusion-free to diffusion-controlled reaction involves changes in the dependence of the reaction rate on film thickness, initiation rate, and monomer concentration. Although the diffusion-free rate is w order in initiation rate, upsilon order in monomer, and independent of film thickness, the diffusion-controlled rate is w/2 order in initiator rate and inverse first-order in film thickness. Dependence of the diffusion-controlled rate on monomer is dependent in a complex manner on the diffusional characteristics of the reaction system. 11 figures, 4 tables

  3. Comparison of Absolute Apparent Diffusion Coefficient (ADC) Values in ADC Maps Generated Across Different Postprocessing Software: Reproducibility in Endometrial Carcinoma.

    Science.gov (United States)

    Ghosh, Adarsh; Singh, Tulika; Singla, Veenu; Bagga, Rashmi; Khandelwal, Niranjan

    2017-12-01

    Apparent diffusion coefficient (ADC) maps are usually generated by builtin software provided by the MRI scanner vendors; however, various open-source postprocessing software packages are available for image manipulation and parametric map generation. The purpose of this study is to establish the reproducibility of absolute ADC values obtained using different postprocessing software programs. DW images with three b values were obtained with a 1.5-T MRI scanner, and the trace images were obtained. ADC maps were automatically generated by the in-line software provided by the vendor during image generation and were also separately generated on postprocessing software. These ADC maps were compared on the basis of ROIs using paired t test, Bland-Altman plot, mountain plot, and Passing-Bablok regression plot. There was a statistically significant difference in the mean ADC values obtained from the different postprocessing software programs when the same baseline trace DW images were used for the ADC map generation. For using ADC values as a quantitative cutoff for histologic characterization of tissues, standardization of the postprocessing algorithm is essential across processing software packages, especially in view of the implementation of vendor-neutral archiving.

  4. Diffusion coefficients of alloying elements in dilute Mg alloys: A comprehensive first-principles study

    International Nuclear Information System (INIS)

    Zhou, Bi-Cheng; Shang, Shun-Li; Wang, Yi; Liu, Zi-Kui

    2016-01-01

    First-principles calculations based on density functional theory have been used to calculate the temperature-dependent dilute tracer diffusion coefficients for 47 substitutional alloying elements in hexagonal closed packed (hcp) Mg by combining transition state theory and an 8-frequency model. The minimum energy pathways and the saddle point configurations during solute migration are calculated with the climbing image nudged elastic band method. Vibrational properties are obtained using the quasi-harmonic Debye model with inputs from first-principles calculations. An improved generalized gradient approximation of PBEsol is used in the present first-principles calculations, which is able to well describe both vacancy formation energies and vibrational properties. It is found that the solute diffusion coefficients in hcp Mg are roughly inversely proportional to the bulk modulus of the dilute alloys, which reflects the solutes' bonding to Mg. Transition metal elements with d electrons show strong interactions with Mg and have large diffusion activation energies. Correlation effects are not negligible for solutes Ca, Na, Sr, Se, Te, and Y, in which the direct solute migration barriers are much smaller than the solvent (Mg) migration barriers. Calculated diffusion coefficients are in remarkable agreement with available experimental data in the literature.

  5. B0-correction and k-means clustering for accurate and automatic identification of regions with reduced apparent diffusion coefficient (ADC) in adva nced cervical cancer at the time of brachytherapy

    DEFF Research Database (Denmark)

    Haack, Søren; Pedersen, Erik Morre; Vinding, Mads Sloth

    in dose planning of radiotherapy. This study evaluates the use of k-means clustering for automatic user independent delineation of regions of reduced apparent diffusion coefficient (ADC) and the value of B0-correction of DW-MRI for reduction of geometrical distortions during dose planning of brachytherapy...

  6. Diffusion coefficients of radon in candidate soils for covering uranium mill tailings

    International Nuclear Information System (INIS)

    Kalkwarf, D.R.; Silker, W.B.

    1983-10-01

    Diffusion coefficients were measured for radon in 34 soils that had been identified by uranium mill personnel as candidate soils for covering their tailings piles in order to reduce radon emission. The coefficients referred to diffusion in the total pore space of the soils. They were measured by a steady-state method using soil columns compacted to greater than 80% of their Proctor maximum packing densities, but with moisture contents generally less than would be expected at a tailings site. Three published empirical equations relating diffusion coefficients to soil moisture and porosity were tested with these data. The best fir was obtained with the equation: D = 0.70 exp [-4(m-mP 2 +m 5 )] in which P is the dry porosity of the soil and m is its moisture saturation, i.e. the fraction of pore volume filled with water. This equation was used to extrapolate measured coefficients to values expected at soil-moisture contents representative of tailings sites in the western United States. Extrapolated values for silty sands and clayey sands range from 0.004 to 0.06 cm 2 /s where w, the weight ratio of water to dry soil, is expected to vary from 0.04 to 0.09. Values for inorganic silts and clays ranged from 0.001 to 0.02 cm 2 /s where w is expected to vary from 0.10 to 0.13. 8 references, 1 figure, 1 table

  7. Median nerve cross-sectional area and MRI diffusion characteristics: normative values at the carpal tunnel

    International Nuclear Information System (INIS)

    Yao, Lawrence; Gai, Neville

    2009-01-01

    Enlargement of the median nerve is an objective potential imaging sign of carpal tunnel syndrome. Diffusion tensor MRI (DTI) may provide additional structural information that may prove useful in characterizing median neuropathy. This study further examines normal values for median nerve cross-sectional area (CSA), apparent diffusion coefficient (ADC), and fractional anisotropy (FA). Twenty-three wrists in 17 healthy volunteers underwent MRI of the wrist at 3 T. In 13 subjects, DTI was performed at a B value of 600 mm 2 /s. Median nerve CSA, ADC, and FA were analyzed at standardized anatomic levels. Mean (SD) median nerve CSA within the proximal carpal tunnel was 10.0 (3.4) mm 2 . The mean (SD) FA of the median nerve was 0.71 (0.06) and 0.70 (0.13) proximal to and within the carpal tunnel, respectively. There was a significant difference between nerve CSA and ADC, but not FA, at the distal forearm and proximal carpal tunnel. Nerve CSA, ADC, and FA did not differ between men and women or between dominant and non-dominant wrists. Nerve CSA at the proximal carpal tunnel was positively correlated with subject age and body mass index. Our results suggest a 90% upper confidence limit for normal median nerve CSA of 14.4 mm 2 at the proximal carpal tunnel, higher than normal limits reported by many ultrasound studies. We observed a difference between the CSA and ADC, but not the FA, of the median nerve at the distal forearm and proximal carpal tunnel levels. (orig.)

  8. Evaluation of downwelling diffuse attenuation coefficient algorithms in the Red Sea

    KAUST Repository

    Tiwari, Surya Prakash

    2016-05-07

    Despite the importance of the optical properties such as the downwelling diffuse attenuation coefficient for characterizing the upper water column, until recently no in situ optical measurements were published for the Red Sea. Kirby et al. used observations from the Coastal Zone Color Scanner to characterize the spatial and temporal variability of the diffuse attenuation coefficient (Kd(490)) in the Red Sea. To better understand optical variability and its utility in the Red Sea, it is imperative to comprehend the diffuse attenuation coefficient and its relationship with in situ properties. Two apparent optical properties, spectral remote sensing reflectance (Rrs) and the downwelling diffuse attenuation coefficient (Kd), are calculated from vertical profile measurements of downwelling irradiance (Ed) and upwelling radiance (Lu). Kd characterizes light penetration into water column that is important for understanding both the physical and biogeochemical environment, including water quality and the health of ocean environment. Our study tests the performance of the existing Kd(490) algorithms in the Red Sea and compares them against direct in situ measurements within various subdivisions of the Red Sea. Most standard algorithms either overestimated or underestimated with the measured in situ values of Kd. Consequently, these algorithms provided poor retrieval of Kd(490) for the Red Sea. Random errors were high for all algorithms and the correlation coefficients (r2) with in situ measurements were quite low. Hence, these algorithms may not be suitable for the Red Sea. Overall, statistical analyses of the various algorithms indicated that the existing algorithms are inadequate for the Red Sea. The present study suggests that reparameterizing existing algorithms or developing new regional algorithms is required to improve retrieval of Kd(490) for the Red Sea. © (2016) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is

  9. Diffusion weighted imaging of liver lesions suspect for metastases: Apparent diffusion coefficient (ADC) values and lesion contrast are independent from Gd-EOB-DTPA administration

    International Nuclear Information System (INIS)

    Benndorf, Matthias; Schelhorn, Juliane; Dietzel, Matthias; Kaiser, Werner A.; Baltzer, Pascal A.T.

    2012-01-01

    Purpose: Gadolinium ethoxybenzyl diethylenetriamine pentaacetic acid (Gd-EOB-DTPA) enhanced liver MRI is widely used for detection and differentiation of focal liver lesions. Diffusion weighted imaging (DWI) including apparent diffusion coefficient (ADC) measurements is increasingly utilised as a fast and, with limitations, quantitative method for liver lesion detection and characterisation. Herein we investigate whether the administration of Gd-EOB-DTPA affects DWI. Materials and methods: 31 consecutive patients referred to standardised liver MRI (1.5 T, Gd-EOB-DTPA, 0.025 mmol/kg) were retrospectively reviewed. All underwent a breathhold DWI sequence before and after contrast agent administration (EPI-DWI, TR/TE (effective): 2100/62 ms, b-values: 0 and 800 s/mm 2 ). Patients with previously treated liver lesions were excluded. Signal intensity of lesion, parenchyma and noise on DWI images as well as the ADC value were measured after identification by two observers in consensus using manually placed regions of interest. The reference standard was imaging follow-up determined separately by two radiologists. Data analysis included signal-to-noise (SNR) ratio and contrast-to-noise ratio (CNR) calculations, comparisons were drawn by employing multiple Bonferroni corrected Wilcoxon signed-rank tests. Results: 50 malignant and 39 benign lesions were identified. Neither SNR, CNR nor ADC values showed significant differences between pre- and postcontrast DWI. Both pre- and postcontrast ADC values differed significantly between benign and malignant lesions (P < 0.001). Conclusion: We did not identify a significant influence of Gd-EOB-DTPA on DWI of liver lesions. This allows for individual tailoring of imaging protocols according to clinical needs.

  10. Conventional and Diffusion-Weighted MRI in the Evaluation of Methanol Poisoning. A case report

    International Nuclear Information System (INIS)

    Server, A.; Nakstad, P.Hj.; Dullerud, R.; Haakonsen, M.; Hovda, K.E.; Jacobsen, D.

    2003-01-01

    Cerebral lesions were studied in 2 methanol-poisoned patients using conventional magnetic resonance imaging (MRI). In 1 patient, diffusion-weighted MRI (DWI) was also performed. In this patient, conventional MRI showed symmetrical, bilateral increased signal in the lentiform nuclei, involving predominantly putamina, but also extending into the corona radiata, centrum semiovale and subcortical white matter. DWI showed decreased diffusion, which most probably reflects cytotoxic edema. In the other patient, fluid attenuated-inversion recovery (FLAIR) and T2-weighted images showed hyperintensity in the putamina, characteristic of post-necrotic changes

  11. Diffusion-weighted MRI - a new parameter for advanced rectal carcinoma?

    International Nuclear Information System (INIS)

    Hein, P.A.; Lukas, P.; DeVries, A.F.; Pfeiffer, K.-P.

    2003-01-01

    Purpose: To evaluate the predictive value of apparent diffusion coefficient (ADC) on therapy outcome of combined chemoradiation in patients with primary carcinoma of the rectum. Materials and Method: Prior to standardized, combined, neoadjuvant chemoradiation, 16 patients with primary carcinoma of the rectum (cT3) were examined with magnetic resonance imaging (MRI). Diffusion weighted spin echo echo-planar images (SE-EPI) and contrast-enhanced T 1 -weighted spin echo (SE) images at 1.5 Tesla were obtained. The mean ADC of the tumor region was calculated and correlated with the therapy outcome substantiated by postsurgical histopathologic staging. Results: Tumor downstaging (pT0-2) occurred in 9 patients (therapy responders) and no down-staging (pT3) in 7 patients (therapy non-responders). The mean ADC measured 0.476±0.114 x 10 -3 mm 2 /s in the responder group and 0.703±0.085 x 10 -3 mm 2 /s in the non-responder group. Comparison of the mean ADC between the groups reached statistical significance (p=0.001). Conclusion: The mean ADC might be a new quantitative parameter to predict therapy outcome of combined preoperative chemoradiation in patients with primary carcinoma of the rectum. (orig.) [de

  12. Characterization of ductal carcinoma in situ on diffusion weighted breast MRI

    International Nuclear Information System (INIS)

    Rahbar, Habib; Partridge, Savannah C.; Eby, Peter R.; DeMartini, Wendy B.; Gutierrez, Robert L.; Peacock, Sue; Lehman, Constance D.

    2011-01-01

    To characterize ductal carcinoma in situ (DCIS) and its subtypes on diffusion-weighted imaging (DWI). We retrospectively reviewed 74 pure DCIS lesions in 69 women who underwent DWI at 1.5 T (b = 0 and 600 s/mm 2 ). Each lesion was characterized by qualitative DWI intensity, quantitative DWI lesion-to-normal contrast-to-noise ratio (CNR), and quantitative apparent diffusion coefficient (ADC). The detection rate was calculated with predetermined thresholds for each parameter. The effects of lesion size, grade, morphology, and necrosis were assessed. Ninety-six percent (71/74) of DCIS lesions demonstrated greater qualitative DWI intensity than normal breast tissue. Quantitatively, DCIS lesions demonstrated on average 56% greater signal than normal tissue (mean CNR = 1.83 ± 2.7) and lower ADC values (1.50 ± 0.28 x 10 -3 mm 2 /s) than normal tissue (2.01 ± 0.37 x 10 -3 mm 2 /s, p -3 mm 2 /s). Non-high-grade DCIS exhibited greater qualitative DWI intensity (p = 0.02) and quantitative CNR (p = 0.01) than high-grade DCIS but no difference in ADC (p = 0.40). Lesion size, morphology, and necrosis did not affect qualitative or quantitative DWI parameters of DCIS lesions (p > 0.05). DCIS lesions have higher DWI signal intensity and lower ADC values than normal breast tissue. DWI warrants further investigation as a potential non-contrast MRI tool for early breast cancer detection. (orig.)

  13. Patterns in early diffusion-weighted MRI in children with haemolytic uraemic syndrome and CNS involvement

    International Nuclear Information System (INIS)

    Donnerstag, Frank; Ding, Xiaoqi; Bueltmann, Eva; Zajaczek, Jan; Lanfermann, Heinrich; Pape, Lars; Das, Anibh Martin; Ehrich, Jochen; Hartmann, Hans; Luecke, Thomas; Hoy, Ludwig

    2012-01-01

    Diffusion-weighted imaging (DWI) in children with diarrhoea associated haemolytic uraemic syndrome (D+HUS) and cerebral involvement was evaluated retrospectively. DWI within 24 h of onset of neurological symptoms. The apparent diffusion coefficient (ADC) was measured in grey/white matter and correlated with clinical and laboratory findings. DWI was abnormal in all. Abnormal ADC was detected in the supratentorial white matter (6/12) and cortex (1/12), the basal ganglia (5/12), the thalami (4/12), and the cerebellum (1/12). ADC was reduced in 5/12, increased in 4/12, and both in 3/12. Mean serum sodium was lower in patients with DWI abnormalities affecting the white matter (6/12), than in those with basal ganglia/thalamic involvement (6/12). Neurological outcome was normal in 4/11 and abnormal in 7/11, and 1 patient died, outcome did not correlate to either localisation or type of DWI abnormality. In D+HUS with neurological symptoms, early DWI may reveal abnormal ADC not only in the basal ganglia/thalami, but also in the white matter/cortex. Besides thrombotic microangiopathy, toxic effects of shiga toxin, azotaemia and hyponatraemia / hypoosmolality may be involved in cerebral involvement in children with D+HUS. Findings on early MRI seem not to predict clinical course or outcome. (orig.)

  14. Patterns in early diffusion-weighted MRI in children with haemolytic uraemic syndrome and CNS involvement

    Energy Technology Data Exchange (ETDEWEB)

    Donnerstag, Frank; Ding, Xiaoqi; Bueltmann, Eva; Zajaczek, Jan; Lanfermann, Heinrich [Hannover Medical School, Institute of Diagnostic and Therapeutic Neuroradiology, Hannover (Germany); Pape, Lars; Das, Anibh Martin; Ehrich, Jochen; Hartmann, Hans [Hannover Medical School, Clinic for Pediatric Kidney, Liver and Metabolic Diseases, Hannover (Germany); Luecke, Thomas [Hannover Medical School, Clinic for Pediatric Kidney, Liver and Metabolic Diseases, Hannover (Germany); University of Bochum, Department of Neuropediatrics, Pediatric Hospital, Bochum (Germany); Hoy, Ludwig [Hannover Medical School, Institute of Biometrics, Hannover (Germany)

    2012-03-15

    Diffusion-weighted imaging (DWI) in children with diarrhoea associated haemolytic uraemic syndrome (D+HUS) and cerebral involvement was evaluated retrospectively. DWI within 24 h of onset of neurological symptoms. The apparent diffusion coefficient (ADC) was measured in grey/white matter and correlated with clinical and laboratory findings. DWI was abnormal in all. Abnormal ADC was detected in the supratentorial white matter (6/12) and cortex (1/12), the basal ganglia (5/12), the thalami (4/12), and the cerebellum (1/12). ADC was reduced in 5/12, increased in 4/12, and both in 3/12. Mean serum sodium was lower in patients with DWI abnormalities affecting the white matter (6/12), than in those with basal ganglia/thalamic involvement (6/12). Neurological outcome was normal in 4/11 and abnormal in 7/11, and 1 patient died, outcome did not correlate to either localisation or type of DWI abnormality. In D+HUS with neurological symptoms, early DWI may reveal abnormal ADC not only in the basal ganglia/thalami, but also in the white matter/cortex. Besides thrombotic microangiopathy, toxic effects of shiga toxin, azotaemia and hyponatraemia / hypoosmolality may be involved in cerebral involvement in children with D+HUS. Findings on early MRI seem not to predict clinical course or outcome. (orig.)

  15. MRI-only lesions: application of diffusion-weighted imaging obviates unnecessary MR-guided breast biopsies

    Energy Technology Data Exchange (ETDEWEB)

    Spick, Claudio; Pinker-Domenig, Katja; Helbich, Thomas H.; Baltzer, Pascal A. [Medical University of Vienna (AKH), General Hospital Vienna, Department of Biomedical Imaging and Image-guided Therapy, Division of Molecular and Gender Imaging, Wien (Austria); Rudas, Margaretha [Medical University of Vienna (AKH), Clinical Institute of Pathology, Wien (Austria)

    2014-06-15

    To assess if the application of diffusion-weighted imaging (DWI) obviates unnecessary MR-guided biopsies in suspicious breast lesions visible only on contrast-enhanced MRI (CE-MRI). This institutional review board (IRB)-approved, retrospective, single-centre study included 101 patients (mean age, 49.5; SD 13.9 years) who underwent additional DWI at 1.5 T prior to MRI-guided biopsy of 104 lesions classified as suspicious for malignancy and visible on CE-MRI only. An experienced radiologist, blinded to histopathologic and follow-up results, measured apparent diffusion coefficient (ADC) values obtained from DWI. Diagnostic accuracy was investigated using receiver operating characteristics (ROC) analysis. Histopathology revealed 20 malignant and 84 benign lesions. Lesions were masses in 61 (15 malignant, 24.6 %) and non-masses in 43 cases (five malignant, 11.6 %). Mean ADC values were 1.53 ± 0.38 x 10{sup -3} mm{sup 2}/s in benign lesions and 1.06 ± 0.27 x 10{sup -3} mm{sup 2}/s in malignant lesions. ROC analysis revealed exclusively benign lesions if ADC values were greater than 1.58 x 10{sup -3} mm{sup 2}/s. As a consequence, 29 false-positive biopsies (34.5 %) could have been avoided without any false-negative findings. Both in mass and in non-mass lesions, rule-in and rule-out criteria were identified using flexible ADC thresholds based on ROC analysis. Additional application of DWI in breast lesions visible only on MRI can avoid false-positive, MR-guided biopsies. Thus, DWI should be an integral part of breast MRI protocols. (orig.)

  16. Role of diffusion-weighted MRI in differentiation of hepatic abscesses from non-infected fluid collections.

    Science.gov (United States)

    Schmid-Tannwald, C; Schmid-Tannwald, C M; Morelli, J N; Neumann, R; Reiser, M F; Nikolaou, K; Rist, C

    2014-07-01

    To evaluate the role of diffusion-weighted magnetic resonance imaging (DW-MRI) in the differentiation of hepatic abscesses from non-infected fluid collections. In this retrospective study, 22 hepatic abscesses and 27 non-infected hepatic fluid collections were examined in 27 patients who underwent abdominal MRI including DW-MRI. Two independent observers reviewed T2-weighted + DW-MRI and T2-weighted + contrast-enhanced T1-weighted (CET1W) images in two sessions. Detection rates and confidence levels were calculated and compared using McNemar's and Wilcoxon's signed rank tests, respectively. Apparent diffusion coefficient (ADC) values of abscesses and non-infected fluid collections were compared using the t-test. Receiver operating characteristic (ROC) curves were constructed. There was no statistically significant difference in the accuracy of detecting abscesses using T2-weighted + DW-MRI (both observers: 21/22, 95.5%) versus T2-weighted + CET1W images (observer 1: 21/22, 95.5%; observer 2: 22/22, 100%; p collections (0.83 ± 0.24 versus 2.25 ± 0.61 × 10(-3) mm(2)/s; p collections at a threshold ADC value of 1.36 × 10(-3) mm(2)/s. DW-MRI allows qualitative and quantitative differentiation of abscesses from non-infected fluid collections in the liver. Copyright © 2014 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  17. A new in-situ method to determine the apparent gas diffusion coefficient of soils

    Science.gov (United States)

    Laemmel, Thomas; Paulus, Sinikka; Schack-Kirchner, Helmer; Maier, Martin

    2015-04-01

    Soil aeration is an important factor for the biological activity in the soil and soil respiration. Generally, gas exchange between soil and atmosphere is assumed to be governed by diffusion and Fick's Law is used to describe the fluxes in the soil. The "apparent soil gas diffusion coefficient" represents the proportional factor between the flux and the gas concentration gradient in the soil and reflects the ability of the soil to "transport passively" gases through the soil. One common way to determine this coefficient is to take core samples in the field and determine it in the lab. Unfortunately this method is destructive and needs laborious field work and can only reflect a small fraction of the whole soil. As a consequence insecurity about the resulting effective diffusivity on the profile scale must remain. We developed a new in-situ method using new gas sampling device, tracer gas and inverse soil gas modelling. The gas sampling device contains several sampling depths and can be easily installed into vertical holes of an auger, which allows for fast installation of the system. At the lower end of the device inert tracer gas is injected continuously. The tracer gas diffuses into the surrounding soil. The resulting distribution of the tracer gas concentrations is used to deduce the diffusivity profile of the soil. For Finite Element Modeling of the gas sampling device/soil system the program COMSOL is used. We will present the results of a field campaign comparing the new in-situ method with lab measurements on soil cores. The new sampling pole has several interesting advantages: it can be used in-situ and over a long time; so it allows following modifications of diffusion coefficients in interaction with rain but also vegetation cycle and wind.

  18. Experimental Determination of Drug Diffusion Coefficients in Unstirred Aqueous Environments by Temporally Resolved Concentration Measurements

    DEFF Research Database (Denmark)

    Di Cagno, Massimiliano Pio; Clarelli, Fabrizio; Vabenø, Jon

    2018-01-01

    or the need for dedicated instrumentation. In this work, a simple but reliable method based on time resolved concentration measurements by UV-visible spectroscopy in an unstirred aqueous environment was developed. This method is based on spectroscopic measurement of the variation of the local concentration...... characteristics (i.e. ionic strength and presence of complexing agents) on the diffusivity. The method can be employed in any research laboratory equipped with a standard UV-visible spectrophotometer, and could become a useful and straightforward tool in order to characterize diffusion coefficients...

  19. Effects of MR parameter changes on the quantification of diffusion anisotropy and apparent diffusion coefficient in diffusion tensor imaging: Evaluation using a diffusional anisotropic phantom

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Sang Joon; Choi, Choong Gon; Kim, Jeong Kon [Dept. of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul (Korea, Republic of); Yun, Sung Cheol [Dept. of Biostatistics, University of Ulsan College of Medicine, Seoul (Korea, Republic of); Jeong, Ha Kyu [Dept. of Radiology, East-West Neomedical Center, Kyung Hee University College of Medicine, Seoul (Korea, Republic of); Kim, Eun Ju [Clinical Scientist, MR, Philips Healthcare, Seoul (Korea, Republic of)

    2015-04-15

    To validate the usefulness of a diffusional anisotropic capillary array phantom and to investigate the effects of diffusion tensor imaging (DTI) parameter changes on diffusion fractional anisotropy (FA) and apparent diffusion coefficient (ADC) using the phantom. Diffusion tensor imaging of a capillary array phantom was performed with imaging parameter changes, including voxel size, number of sensitivity encoding (SENSE) factor, echo time (TE), number of signal acquisitions, b-value, and number of diffusion gradient directions (NDGD), one-at-a-time in a stepwise-incremental fashion. We repeated the entire series of DTI scans thrice. The coefficients of variation (CoV) were evaluated for FA and ADC, and the correlation between each MR imaging parameter and the corresponding FA and ADC was evaluated using Spearman's correlation analysis. The capillary array phantom CoVs of FA and ADC were 7.1% and 2.4%, respectively. There were significant correlations between FA and SENSE factor, TE, b-value, and NDGD, as well as significant correlations between ADC and SENSE factor, TE, and b-value. A capillary array phantom enables repeated measurements of FA and ADC. Both FA and ADC can vary when certain parameters are changed during diffusion experiments. We suggest that the capillary array phantom can be used for quality control in longitudinal or multicenter clinical studies.

  20. Diffusion coefficients of Fokker-Planck equation for rotating dust grains in a fusion plasma

    Science.gov (United States)

    Bakhtiyari-Ramezani, M.; Mahmoodi, J.; Alinejad, N.

    2015-11-01

    In the fusion devices, ions, H atoms, and H2 molecules collide with dust grains and exert stochastic torques which lead to small variations in angular momentum of the grain. By considering adsorption of the colliding particles, thermal desorption of H atoms and normal H2 molecules, and desorption of the recombined H2 molecules from the surface of an oblate spheroidal grain, we obtain diffusion coefficients of the Fokker-Planck equation for the distribution function of fluctuating angular momentum. Torque coefficients corresponding to the recombination mechanism show that the nonspherical dust grains may rotate with a suprathermal angular velocity.

  1. Electron scattering on N2O-from cross sections to diffusion coefficients

    International Nuclear Information System (INIS)

    Mechlinska-Drewko, J.; Wroblewski, T.; Petrovic, Z.L.; Novakovic, V.; Karwasz, G.P.

    2003-01-01

    Results of measurements of the ratio of transverse (D T /μ) and longitudinal (D L /μ) diffusion coefficients to mobility and drift velocity (W) as function of reduced electrical field (E/N) for electrons in nitrous oxide are presented. The coefficients D T /μ and D L /μ have been determined by applying the Townsend-Huxley method. The drift velocities were obtained by using the Bradbury-Nielsen technique. Also the deduced set of total and partial cross sections has been used to calculate the D T /μ and W

  2. Cortical fibers orientation mapping using in-vivo whole brain 7 T diffusion MRI

    NARCIS (Netherlands)

    Gulban, Omer F; De Martino, Federico; Vu, An T; Yacoub, Essa; Uğurbil, Kamil; Lenglet, Christophe

    Diffusion MRI of the cortical gray matter is challenging because the micro-environment probed by water molecules is much more complex than within the white matter. High spatial and angular resolutions are therefore necessary to uncover anisotropic diffusion patterns and laminar structures, which