WorldWideScience

Sample records for diagnostic upper port

  1. Engineering issues on the diagnostic port integration in ITER upper port 18

    Energy Technology Data Exchange (ETDEWEB)

    Pak, Sunil, E-mail: paksunil@nfri.re.kr [National Fusion Research Institute, Gwahak-ro, Yuseong-gu, Daejeon (Korea, Republic of); Bertalot, Luciano [ITER Organization, Route de Vinon sur Verdon, 13115 St Paul-lez-Durance (France); Cheon, Mun Seong [National Fusion Research Institute, Gwahak-ro, Yuseong-gu, Daejeon (Korea, Republic of); Giacomin, Thibaud [ITER Organization, Route de Vinon sur Verdon, 13115 St Paul-lez-Durance (France); Heemskerk, Cock J.M.; Koning, Jarich F. [Heemskerk Innovative Technology, Merelhof 2, 2172 HZ Sassenheim (Netherlands); Lee, Hyeon Gon [National Fusion Research Institute, Gwahak-ro, Yuseong-gu, Daejeon (Korea, Republic of); Nemtcev, Grigorii [Institution “PROJECT CENTER ITER”, Akademika Kurchatova sq., Moscow (Russian Federation); Ronden, Dennis M.S. [FOM Institute DIFFER, P.O. Box 1207, 3430 BE Nieuwegein (Netherlands); Seon, Chang Rae [National Fusion Research Institute, Gwahak-ro, Yuseong-gu, Daejeon (Korea, Republic of); Udintsev, Victor; Yukhnov, Nikolay [ITER Organization, Route de Vinon sur Verdon, 13115 St Paul-lez-Durance (France); Zvonkov, Alexander [Institution “PROJECT CENTER ITER”, Akademika Kurchatova sq., Moscow (Russian Federation)

    2016-11-01

    Highlights: • Diagnostic port integration in the upper port 18 of ITER is presented in order to house the three diagnostic systems. • Issue on the neutron shielding in the upper port 18 is addressed and the shut-down dose rate in the interspace is summarized. • The maintenance strategy in the upper port 18 is described. - Abstract: The upper port #18 (UP18) in ITER hosts three diagnostic systems: the neutron activation system, the Vacuum Ultra-Violet spectrometer system, and the vertical neutron camera. These diagnostics are integrated into three infrastructures in the port: the upper port plug, interspace support structure and port cell support structure. The port integration in UP18 is at the preliminary design stage and the current design of the infrastructure as well as the diagnostic integration is described here. The engineering issues related to neutron shielding and maintenance are addressed and the design approach is suggested.

  2. Numerical simulation on bake-out of the ITER diagnostic upper port plug

    International Nuclear Information System (INIS)

    Pak, S.; Pitcher, C.S.; Kalish, M.R.; Cheon, M.S.; Seon, C.R.; Lee, H.G.

    2010-01-01

    The diagnostic upper port plug in ITER is fixed to the upper port of the vacuum vessel as a cantilevered beam with bolts and forms a primary vacuum boundary. It needs to be baked out for outgassing before normal operation. This study calculated the required bake-out time and the transient thermal stress during baking for the diagnostic upper port plug. The calculation was done through numerical simulation. The analysis took into consideration the gradual temperature increase of working fluid. In order to look into the effect of radiation heat transfer from the upper port plug to the vacuum vessel port, the upper vacuum vessel port was included in this analysis.

  3. Shutdown dose rate contribution from diagnostics in ITER upper port 18

    Energy Technology Data Exchange (ETDEWEB)

    Cheon, M.S., E-mail: munseong@nfri.re.kr [National Fusion Research Institute, Daejeon (Korea, Republic of); Pak, S.; An, Y.H.; Seon, C.R.; Lee, H.G. [National Fusion Research Institute, Daejeon (Korea, Republic of); Bertalot, L.; Krasilnikov, V. [ITER Organization, St Paul-lez-Durance (France); Zvonkov, A. [Agency ITER-RF, Moscow (Russian Federation)

    2016-11-01

    Highlights: • The Shutdown Dose Rate in the interspace of ITER upper port 18 was evaluated. • VUV spectrometer is the dominant contributor to the average SDR. • The existence and size of the blanket cooling pipes impacts significantly on SDR. - Abstract: D-T operation of ITER plasma will produce high-energy fusion neutrons those can activate materials around the place where human-access is necessary. The interspace of the diagnostic port is one of the area where human-access is necessary for the maintenance of diagnostic systems installed at the port, so it is important to evaluate a dose rate of the interspace area in order to comply with ALARA principle. The shutdown dose rate (SDR) in the interspace of ITER upper port 18 was evaluated by the Direct 1-Step (D1S) method using MCNP5 code. This port contains three diagnostics: Vacuum Ultra-Violet (VUV) Spectrometer, Neutron Activation System (NAS), and Upper Vertical Neutron Camera (UVNC). The contribution of each diagnostic in the port was evaluated by running separate upper port MCNP models those contain individual diagnostic only, and the total dose rate contribution was evaluated with the model which was fully integrated with all the diagnostics. The effect of the opening around the upper port plug and of the other ports was also investigated. The purpose of this assessment is to provide the shielding design basis for the preliminary design of the diagnostic integration in the port. The method and result of the calculation will be presented in this paper.

  4. Final design of the generic upper port plug structure for ITER diagnostic systems

    Energy Technology Data Exchange (ETDEWEB)

    Pak, Sunil, E-mail: paksunil@nfri.re.kr [National Fusion Research Institute, Daejeon (Korea, Republic of); Feder, Russell [Princeton Plasma Physics Laboratory, Princeton, NJ (United States); Giacomin, Thibaud; Guirao, Julio; Iglesias, Silvia; Josseaume, Fabien [ITER Organization, Route de Vinon sur Verdon, 13115 St Paul-lez-Durance (France); Kalish, Michael; Loesser, Douglas [Princeton Plasma Physics Laboratory, Princeton, NJ (United States); Maquet, Philippe [ITER Organization, Route de Vinon sur Verdon, 13115 St Paul-lez-Durance (France); Ordieres, Javier; Panizo, Marcos [NATEC, Ingenieros, Gijón (Spain); Pitcher, Spencer; Portalès, Mickael [ITER Organization, Route de Vinon sur Verdon, 13115 St Paul-lez-Durance (France); Proust, Maxime [CEA, Cadarache, St. Paul-lez-Durance (France); Ronden, Dennis [FOM Institute DIFFER, Nieuwegein (Netherlands); Serikov, Arkady [Karlsruhe Institute of Technology, Eggenstein-Leopoldshafen (Germany); Suarez, Alejandro [ITER Organization, Route de Vinon sur Verdon, 13115 St Paul-lez-Durance (France); Tanchuk, Victor [NIIEFA, St.-Petersburg (Russian Federation); Udintsev, Victor; Vacas, Christian [ITER Organization, Route de Vinon sur Verdon, 13115 St Paul-lez-Durance (France); and others

    2016-01-15

    The generic upper port plug (GUPP) structure in ITER is a 6 m long metal box which deploys diagnostic components into the vacuum vessel. This structure is commonly used for all the diagnostic upper ports. The final design of the GUPP structure, which has successfully passed the final design review in 2013, is described here. The diagnostic port plug is cantilevered to the vacuum vessel with a heavy payload at the front, so called the diagnostic first wall (DFW) and the diagnostic shield module (DSM). Most of electromagnetic (EM) load (∼80%) occurs in DFW/DSM. Therefore, the mounting design to transfer the EM load from DFW/DSM to the GUPP structure is challenging, which should also comply with thermal expansion and tolerance for assembly and manufacturing. Another key design parameter to be considered is the gap between the port plug and the vacuum vessel port. The gap should be large enough to accommodate the remote handling of the heavy port plug (max. 25 t), the structural deflection due to external loads and machine assembly tolerance. At the same time, the gap should be minimized to stop the neutron streaming according to the ALARA (as low as reasonably achievable) principle. With these design constraints, the GUPP structure should also provide space for diagnostic integration as much as possible. This requirement has led to the single wall structure having the gun-drilled water channels inside the structure. Furthermore, intensive efforts have been made on the manufacturing study including material selection, manufacturing codes and French regulation related to nuclear equipment and safety. All these main design and manufacturing aspects are discussed in this paper, including requirements, interfaces, loads and structural assessment and maintenance.

  5. Evaluation of electromagnetic loads on various design options of the ITER diagnostic upper port plug during plasma disruptions

    International Nuclear Information System (INIS)

    Pak, Sunil; Ku, Duck Young; Oh, Dong-Keun; Jhang, Hogun; Kim, Duck-Hoi; Cheon, Mun-Seong; Seon, Chang Rae; Lee, Hyeon Gon; Pitcher, Spencer

    2011-01-01

    Electromagnetic (EM) loads due to eddy current and halo current during plasma disruptions are evaluated for the ITER diagnostic upper port plug. To reduce strong EM loads acting on the port plug fixed to the vacuum vessel like a cantilever beam, three design options have been considered: removal of the diagnostic first wall, slitting of the diagnostic shield module and recess of the port plug. The main focus of the present study is to examine the efficacy of these options in terms of EM loads on the upper port plug. It is found that making slits is more effective than removing the first wall. It is also shown that the upper port plug needs to be recessed to reduce the EM load induced by halo current.

  6. ITER Generic Diagnostic Upper Port Plug Nuclear Heating and Personnel Dose Rate Assessment

    International Nuclear Information System (INIS)

    Feder, Russell E.; Youssef, Mahmoud Z.

    2009-01-01

    Neutronics analysis to find nuclear heating rates and personnel dose rates were conducted in support of the integration of diagnostics in to the ITER Upper Port Plugs. Simplified shielding models of the Visible-Infrared diagnostic and of a large aperture diagnostic were incorporated in to the ITER global CAD model. Results for these systems are representative of typical designs with maximum shielding and a small aperture (Vis-IR) and minimal shielding with a large aperture. The neutronics discrete-ordinates code ATTILA(reg s ign) and SEVERIAN(reg s ign) (the ATTILA parallel processing version) was used. Material properties and the 500 MW D-T volume source were taken from the ITER 'Brand Model' MCNP benchmark model. A biased quadrature set equivalent to Sn=32 and a scattering degree of Pn=3 were used along with a 46-neutron and 21-gamma FENDL energy subgrouping. Total nuclear heating (neutron plug gamma heating) in the upper port plugs ranged between 380 and 350 kW for the Vis-IR and Large Aperture cases. The Large Aperture model exhibited lower total heating but much higher peak volumetric heating on the upper port plug structure. Personnel dose rates are calculated in a three step process involving a neutron-only transport calculation, the generation of activation volume sources at pre-defined time steps and finally gamma transport analyses are run for selected time steps. ANSI-ANS 6.1.1 1977 Flux-to-Dose conversion factors were used. Dose rates were evaluated for 1 full year of 500 MW DT operation which is comprised of 3000 1800-second pulses. After one year the machine is shut down for maintenance and personnel are permitted to access the diagnostic interspace after 2-weeks if dose rates are below 100 (micro)Sv/hr. Dose rates in the Visible-IR diagnostic model after one day of shutdown were 130 (micro)Sv/hr but fell below the limit to 90 (micro)Sv/hr 2-weeks later. The Large Aperture style shielding model exhibited higher and more persistent dose rates. After 1

  7. Starting manufacturing phase of ITER upper ports

    Energy Technology Data Exchange (ETDEWEB)

    Utin, Yuri, E-mail: yuri.utin@iter.org [ITER Organization, Route de Vinon-sur-Verdon, CS 90 046, 13067 St. Paul Lez Durance Cedex (France); Alekseev, Alexander; Sborchia, Carlo; Choi, Changho; Albin, Vincent; Barabash, Vladimir; Davis, James [ITER Organization, Route de Vinon-sur-Verdon, CS 90 046, 13067 St. Paul Lez Durance Cedex (France); Fabritsiev, Sergey [NTC Sintez, Efremov Inst., 189631 Metallostroy, St. Petersburg (Russian Federation); Giraud, Benoit; Guirao, Julio [ITER Organization, Route de Vinon-sur-Verdon, CS 90 046, 13067 St. Paul Lez Durance Cedex (France); Koenig, Werner [MAN Diesel & Turbo SE, Werftstrasse 17, Deggendorf (Germany); Kedrov, Igor; Kuzmin, Evgeny [NTC Sintez, Efremov Inst., 189631 Metallostroy, St. Petersburg (Russian Federation); Levesy, Bruno; Martinez, Jean-Marc [ITER Organization, Route de Vinon-sur-Verdon, CS 90 046, 13067 St. Paul Lez Durance Cedex (France); Prebeck, Markus [MAN Diesel & Turbo SE, Werftstrasse 17, Deggendorf (Germany); Privalova, Elena [NTC Sintez, Efremov Inst., 189631 Metallostroy, St. Petersburg (Russian Federation); Ranzinger, Franz [MAN Diesel & Turbo SE, Werftstrasse 17, Deggendorf (Germany); Savrukhin, Petr [Russian Federation ITER Domestic Agency, Kurchatov sq.1, 123182 Moscow (Russian Federation); Schiller, Thomas [MAN Diesel & Turbo SE, Werftstrasse 17, Deggendorf (Germany); and others

    2015-10-15

    Highlights: • The port plugs are attached to the ports with high-strength fasteners. • Tightening of the fasteners via inductive heating was tested. • A concept for the port/plug sealing with metal-type gaskets has progressed. • Manufacturing design of the Upper Ports is in progress. • A full-scale mock-up of double-wall part of the port stub extension is in manufacturing process – acceptable final tolerances are expected. - Abstract: The ITER Vacuum Vessel (VV) features upper, equatorial and lower ports. The upper and regular equatorial ports are occupied by the port plugs. Although the port design has been overall completed in the past, the design of some remaining interfaces was still in progress: in particular, the Sealing Flange package, which includes the high-vacuum seals and the plug fasteners. As the ITER construction phase has started, the procurement of the VV ports has been launched. The VV upper ports will be procured by the Russian Federation Domestic Agency. The main suppliers were selected and the manufacturing design of the first parts is in full progress now. Since the VV is classified at nuclear level N2, the design and manufacture of its components are to be compliant with the French RCC-MR code and regulations for nuclear pressure equipment in France. These regulations make a strong impact to the port design and manufacturing process.

  8. Starting manufacturing phase of ITER upper ports

    International Nuclear Information System (INIS)

    Utin, Yuri; Alekseev, Alexander; Sborchia, Carlo; Choi, Changho; Albin, Vincent; Barabash, Vladimir; Davis, James; Fabritsiev, Sergey; Giraud, Benoit; Guirao, Julio; Koenig, Werner; Kedrov, Igor; Kuzmin, Evgeny; Levesy, Bruno; Martinez, Jean-Marc; Prebeck, Markus; Privalova, Elena; Ranzinger, Franz; Savrukhin, Petr; Schiller, Thomas

    2015-01-01

    Highlights: • The port plugs are attached to the ports with high-strength fasteners. • Tightening of the fasteners via inductive heating was tested. • A concept for the port/plug sealing with metal-type gaskets has progressed. • Manufacturing design of the Upper Ports is in progress. • A full-scale mock-up of double-wall part of the port stub extension is in manufacturing process – acceptable final tolerances are expected. - Abstract: The ITER Vacuum Vessel (VV) features upper, equatorial and lower ports. The upper and regular equatorial ports are occupied by the port plugs. Although the port design has been overall completed in the past, the design of some remaining interfaces was still in progress: in particular, the Sealing Flange package, which includes the high-vacuum seals and the plug fasteners. As the ITER construction phase has started, the procurement of the VV ports has been launched. The VV upper ports will be procured by the Russian Federation Domestic Agency. The main suppliers were selected and the manufacturing design of the first parts is in full progress now. Since the VV is classified at nuclear level N2, the design and manufacture of its components are to be compliant with the French RCC-MR code and regulations for nuclear pressure equipment in France. These regulations make a strong impact to the port design and manufacturing process.

  9. Design and integration of lower ports for ITER diagnostic systems

    Energy Technology Data Exchange (ETDEWEB)

    Casal, Natalia, E-mail: Natalia.casal@iter.org [ITER Organization, Route de Vinon-sur-Verdon – CS 90 046 – 13067 St Paul Lez Durance Cedex (France); Bertalot, Luciano; Cheng, Hao; Drevon, Jean Marc; Duckworth, Philip; Giacomin, Thibaud; Guirao, Julio; Iglesias, Silvia [ITER Organization, Route de Vinon-sur-Verdon – CS 90 046 – 13067 St Paul Lez Durance Cedex (France); Kochergin, Mikhail [IOFFE Institute, Saint Petersburg (Russian Federation); Martin, Alex [ITER Organization, Route de Vinon-sur-Verdon – CS 90 046 – 13067 St Paul Lez Durance Cedex (France); McCarron, Eddie [Oxford Technologies Ltd., Abingdon (United Kingdom); Mokeev, Alexander [Russian Federation Domestic Agency, Moscow (Russian Federation); Mota, Fernando [CIEMAT, Madrid (Spain); Penot, Christophe; Portales, Mickael [ITER Organization, Route de Vinon-sur-Verdon – CS 90 046 – 13067 St Paul Lez Durance Cedex (France); Kitazawa, Sin-iti [Japanese Domestic Agency, Naka (Japan); Sky, Jack [Oxford Technologies Ltd., Abingdon (United Kingdom); Suarez, Alejandro; Udintsev, Victor; Utin, Yuri [ITER Organization, Route de Vinon-sur-Verdon – CS 90 046 – 13067 St Paul Lez Durance Cedex (France); and others

    2015-10-15

    Highlights: • Lower port structures are in its conceptual design phase. • Electromagnetic and seismic loads, will dominate all other mechanical loads. • Design allows diagnostics support, neutron shielding while and signals transmission. • Installation and maintenance operations are fully remote handling compatible. - Abstract: All around the ITER vacuum vessel, forty-four ports will provide access to the vacuum vessel for remote handling operations, diagnostic systems, heating, and vacuum systems: 18 upper ports, 17 equatorial ports, and 9 lower ports. Among the lower ports, three of them will be used for the remote handling installation of the ITER divertor. Once the divertor is in place, these ports will host various diagnostic systems mounted in the so-called diagnostic racks. The diagnostic racks must allow the support and cooling of the diagnostics, extraction of the required diagnostic signals, and providing access and maintainability while minimizing the leakage of radiation toward the back of the port where the humans are allowed to enter. A fully integrated inner rack, carrying the near plasma diagnostic components, will be an stainless steel structure, 4.2 m long, with a maximum weight of 10 t. This structure brings water for cooling and baking at maximum temperature of 240 °C and provides connection with gas, vacuum and electric services. Additional racks (placed away from plasma and not requiring cooling) may be required for the support of some particular diagnostic components. The diagnostics racks and its associated ex vessel structures, which are in its conceptual design phase, are being designed to survive the lifetime of ITER of 20 years. This paper presents the current state of development including interfaces, diagnostic integration, operation and maintenance, shielding requirements, remote handling, loads cases and discussion of the main challenges coming from the severe environment and engineering requirements.

  10. CAD-Based Shielding Analysis for ITER Port Diagnostics

    Directory of Open Access Journals (Sweden)

    Serikov Arkady

    2017-01-01

    Full Text Available Radiation shielding analysis conducted in support of design development of the contemporary diagnostic systems integrated inside the ITER ports is relied on the use of CAD models. This paper presents the CAD-based MCNP Monte Carlo radiation transport and activation analyses for the Diagnostic Upper and Equatorial Port Plugs (UPP #3 and EPP #8, #17. The creation process of the complicated 3D MCNP models of the diagnostics systems was substantially accelerated by application of the CAD-to-MCNP converter programs MCAM and McCad. High performance computing resources of the Helios supercomputer allowed to speed-up the MCNP parallel transport calculations with the MPI/OpenMP interface. The found shielding solutions could be universal, reducing ports R&D costs. The shield block behind the Tritium and Deposit Monitor (TDM optical box was added to study its influence on Shut-Down Dose Rate (SDDR in Port Interspace (PI of EPP#17. Influence of neutron streaming along the Lost Alpha Monitor (LAM on the neutron energy spectra calculated in the Tangential Neutron Spectrometer (TNS of EPP#8. For the UPP#3 with Charge eXchange Recombination Spectroscopy (CXRS-core, an excessive neutron streaming along the CXRS shutter, which should be prevented in further design iteration.

  11. CAD-Based Shielding Analysis for ITER Port Diagnostics

    Science.gov (United States)

    Serikov, Arkady; Fischer, Ulrich; Anthoine, David; Bertalot, Luciano; De Bock, Maartin; O'Connor, Richard; Juarez, Rafael; Krasilnikov, Vitaly

    2017-09-01

    Radiation shielding analysis conducted in support of design development of the contemporary diagnostic systems integrated inside the ITER ports is relied on the use of CAD models. This paper presents the CAD-based MCNP Monte Carlo radiation transport and activation analyses for the Diagnostic Upper and Equatorial Port Plugs (UPP #3 and EPP #8, #17). The creation process of the complicated 3D MCNP models of the diagnostics systems was substantially accelerated by application of the CAD-to-MCNP converter programs MCAM and McCad. High performance computing resources of the Helios supercomputer allowed to speed-up the MCNP parallel transport calculations with the MPI/OpenMP interface. The found shielding solutions could be universal, reducing ports R&D costs. The shield block behind the Tritium and Deposit Monitor (TDM) optical box was added to study its influence on Shut-Down Dose Rate (SDDR) in Port Interspace (PI) of EPP#17. Influence of neutron streaming along the Lost Alpha Monitor (LAM) on the neutron energy spectra calculated in the Tangential Neutron Spectrometer (TNS) of EPP#8. For the UPP#3 with Charge eXchange Recombination Spectroscopy (CXRS-core), an excessive neutron streaming along the CXRS shutter, which should be prevented in further design iteration.

  12. Support structure concept for integration of ITER diagnostics in the port cell

    Energy Technology Data Exchange (ETDEWEB)

    Udintsev, V.S., E-mail: victor.udintsev@iter.org [ITER Organization, Route de Vinon sur Verdon, 13115 St. Paul-Lez-Durance (France); Portalès, M.; Giacomin, T.; Darcourt, O.; Direz, M.-F.; Martins, J.P.; Penot, C.; Arumugam, A.P.; Drevon, J.-M.; Friconneau, J.P.; Levesy, B.; Maquet, P.; Patel, K.M.; Pitcher, C.S. [ITER Organization, Route de Vinon sur Verdon, 13115 St. Paul-Lez-Durance (France); Popova, E. [Russian Federation Domestic Agency, Moscow (Russian Federation); Proust, M. [ITER Organization, Route de Vinon sur Verdon, 13115 St. Paul-Lez-Durance (France); Ronden, D.M.S. [DIFFER, Nieuwegein (Netherlands); Walker, C.I.; Walsh, M.J.; Watts, C. [ITER Organization, Route de Vinon sur Verdon, 13115 St. Paul-Lez-Durance (France)

    2013-10-15

    Highlights: ► An interspace support structure to support the diagnostic systems from the back of the upper and equatorial port plugs to the biological shield plug. ► Port cell support structures are foreseen to handle the equipment in the port cell. ► Both ISS and PCSS will be supported by means of RH rail system. ► The structures will be positioned with a certain tolerance. ► The proposed concepts are found to fulfil the needs for support of the diagnostics in ITER. -- Abstract: Development of the diagnostics for ITER tokamak, which is presently under construction by several international partners at Cadarache in France, is a major challenge because of severe environment, strict engineering requirements, and the need for high reliability in the measurements. The diagnostic systems in the upper, equatorial and lower port cells on ITER are designed to be integrated within the interspace and port cell support structures. These structures are interfacing with remote handling rail system for the cask operations, thus facilitating the removal and installation of the diagnostics in the port and hence minimizing time for working close to the tokamak. In this paper, the challenges associated with the integration of the diagnostics in the port interspace and port cell, as well as their solutions will be addressed and presented. The interspace and the port cell support structures, as well as their interfaces with the biological shield, will be discussed.

  13. A conceptual design of the ITER upper port plug structure and its cooling channels

    International Nuclear Information System (INIS)

    Pak, S.I.; Lee, H.G.; Jung, K.J.; Walker, C.I.; Kim, D.G.; Choi, K.S.

    2008-01-01

    A study is conducted on the conceptual design of the structure and cooling channels of the upper port plug of International Thermonuclear Experimental Reactor (ITER). Modification of the earlier port plug design is made and a simple fabrication method is proposed. It is shown that the newly designed port plug can accommodate the installation of both diagnostic and electron cyclotron heating (ECH) devices. Design assessment is carried out through structural and thermo-hydraulic analyses. Results of the analyses show that the port plug structure is stable against one of the most severe plasma events and the total pressure drop of the coolant is within the allowable level

  14. Process and overview of diagnostics integration in ITER ports

    International Nuclear Information System (INIS)

    Drevon, J.M.; Walsh, M.; Andrew, P.; Barnsley, R.; Bertalot, L.; Bock, M. de; Bora, D.; Bouhamou, R.; Direz, M.F.; Encheva, A.; Fang, T.; Feder, R.; Giacomin, T.; Hellermann, M. von; Jakhar, S.; Johnson, D.; Kaschuk, Y.; Kusama, Y.; Lee, H.G.; Levesy, B.

    2013-01-01

    Highlights: ► An overview of the Port Integration hardware for tenant system hosting inside ITER diagnostics ports is given. ► The main challenges for diagnostic port integration engineering are presented. ► The actions taken for a common modular approach and a coordinated design are detailed. -- Abstract: ITER will have a set of 45 diagnostics to ensure controlled operation. Many of them are integrated in the ITER ports. This paper addresses the integration process of the diagnostic systems and the approach taken to enable coordinated progress. An overview of the Port Integration hardware introduces the various structures needed for hosting tenant systems inside ITER diagnostics ports. The responsibilities of the different parties involved (ITER Organization and the Domestic Agencies) are outlined. The main challenges for diagnostic port integration engineering are summarized. The plan for a common approach to design and manufacture of the supporting structures, in particular the Port Plug is detailed. A coordinated design including common components and a common approach for neutronic analyses is proposed. One particular port, the equatorial port 11, is used to illustrate the approach

  15. Neutronics analysis for integration of ITER diagnostics port EP10

    Energy Technology Data Exchange (ETDEWEB)

    Colling, Bethany, E-mail: bethany.colling@ccfe.ac.uk [Culham Centre for Fusion Energy, Culham Science Centre, Abingdon, Oxon OX14 3DB (United Kingdom); Department of Engineering, Lancaster University, Lancashire LA1 4YR (United Kingdom); Eade, Tim [Culham Centre for Fusion Energy, Culham Science Centre, Abingdon, Oxon OX14 3DB (United Kingdom); Joyce, Malcolm J. [Department of Engineering, Lancaster University, Lancashire LA1 4YR (United Kingdom); Pampin, Raul; Seyvet, Fabien [Fusion for Energy, Josep Pla 2, Torres Diagonal Litoral B3, 08019 Barcelona (Spain); Turner, Andrew [Culham Centre for Fusion Energy, Culham Science Centre, Abingdon, Oxon OX14 3DB (United Kingdom); Udintsev, Victor [ITER Organization, Route de Vinon-sur-Verdon, CS 90 046, 13067 St. Paul Lez Durance Cedex (France)

    2016-11-01

    Shutdown dose rate calculations have been performed on an integrated ITER C-lite neutronics model with equatorial port 10. A ‘fully shielded’ configuration, optimised for a given set of diagnostic designs (i.e. shielding in all available space within the port plug drawers), results in a shutdown dose rate in the port interspace, from the activation of materials comprising equatorial port 10, in excess of 2000 μSv/h. Achieving dose rates of 100 μSv/h or less, as required in areas where hands-on maintenance can be performed, in the port interspace region will be challenging. A combination of methods will need to be implemented, such as reducing mass and/or the use of reduced activation steel in the port interspace, optimisation of the diagnostic designs and shielding of the port interspace floor. Further analysis is required to test these options and the ongoing design optimisation of the EP10 diagnostic systems.

  16. Analysis of ITER upper port plug remote handling maintenance scenarios

    International Nuclear Information System (INIS)

    Koning, J.F.; Baar, M.R. de; Elzendoorn, B.S.Q.; Heemskerk, C.J.M.; Ronden, D.M.S.; Schuth, W.J.

    2012-01-01

    Highlights: ► Remote Handling Study Centre: providing RH compatibility analysis. ► Simulation: virtual reality including kinematics and realtime physics simulator. ► Applied on analysis of RH compatibility of Upper Launcher component replacement. ► Resulting in lowered maintenance procedure time and lessons learned. - Abstract: The ITER tokamak has a modular design, with port plugs, blanket modules and divertor cassettes. This set-up allows for maintenance of diagnostics, heating systems and first wall elements. The maintenance can be done in situ, or in the Hot Cell. Safe and effective remote handling (RH) will be ensured by the RH requirements and standards. Compliance is verified through remote handling compatibility assessments at the ITER Design Review milestones. The Remote Handling Study Centre at FOM Institute DIFFER is created to study ITER RH maintenance processes at different levels of complexity, from relatively simple situational awareness checks using snap-shots in the CAD system, time studies using virtual reality (VR) animations, to extensive operational sequence validation with multiple operators in real-time. The multi-operator facility mimics an RH work-cell as presently foreseen in the ITER RH control room. Novel VR technology is used to create a realistic setting in which a team of RH operators can interact with virtual ITER environments. A physics engine is used to emulate real-time contact interaction as to provide realistic haptic feed-back. Complex interactions between the RH operators and the control room system software are tested. RH task performance is quantified and operational resource usage estimated. The article provides a description and lessons learned from a recent study on replacement of the Steering Mirror Assembly on the ECRH (Electron Cyclotron Resonance Heating) Upper Launcher port plug.

  17. Analysis of ITER upper port plug remote handling maintenance scenarios

    Energy Technology Data Exchange (ETDEWEB)

    Koning, J.F., E-mail: j.f.koning@heemskerk-innovative.nl [FOM Institute DIFFER - Dutch Institute for Fundamental Energy Research, Association EURATOM-FOM, Partner in the Trilateral Euregio Cluster and ITER-NL, PO Box 1207, 3430 BE Nieuwegein (Netherlands); Baar, M.R. de; Elzendoorn, B.S.Q. [FOM Institute DIFFER - Dutch Institute for Fundamental Energy Research, Association EURATOM-FOM, Partner in the Trilateral Euregio Cluster and ITER-NL, PO Box 1207, 3430 BE Nieuwegein (Netherlands); Heemskerk, C.J.M. [Heemskerk Innovative Technology, Noordwijk (Netherlands); Ronden, D.M.S.; Schuth, W.J. [FOM Institute DIFFER - Dutch Institute for Fundamental Energy Research, Association EURATOM-FOM, Partner in the Trilateral Euregio Cluster and ITER-NL, PO Box 1207, 3430 BE Nieuwegein (Netherlands)

    2012-08-15

    Highlights: Black-Right-Pointing-Pointer Remote Handling Study Centre: providing RH compatibility analysis. Black-Right-Pointing-Pointer Simulation: virtual reality including kinematics and realtime physics simulator. Black-Right-Pointing-Pointer Applied on analysis of RH compatibility of Upper Launcher component replacement. Black-Right-Pointing-Pointer Resulting in lowered maintenance procedure time and lessons learned. - Abstract: The ITER tokamak has a modular design, with port plugs, blanket modules and divertor cassettes. This set-up allows for maintenance of diagnostics, heating systems and first wall elements. The maintenance can be done in situ, or in the Hot Cell. Safe and effective remote handling (RH) will be ensured by the RH requirements and standards. Compliance is verified through remote handling compatibility assessments at the ITER Design Review milestones. The Remote Handling Study Centre at FOM Institute DIFFER is created to study ITER RH maintenance processes at different levels of complexity, from relatively simple situational awareness checks using snap-shots in the CAD system, time studies using virtual reality (VR) animations, to extensive operational sequence validation with multiple operators in real-time. The multi-operator facility mimics an RH work-cell as presently foreseen in the ITER RH control room. Novel VR technology is used to create a realistic setting in which a team of RH operators can interact with virtual ITER environments. A physics engine is used to emulate real-time contact interaction as to provide realistic haptic feed-back. Complex interactions between the RH operators and the control room system software are tested. RH task performance is quantified and operational resource usage estimated. The article provides a description and lessons learned from a recent study on replacement of the Steering Mirror Assembly on the ECRH (Electron Cyclotron Resonance Heating) Upper Launcher port plug.

  18. Engineering activities on the ITER representative diagnostic equatorial port plug

    International Nuclear Information System (INIS)

    Meunier, L.; Doceul, L.; Salasca, S.; Martins, J.-P.; Jullien, F.; Dechelle, Christian; Bidaud, Pierre; Pilard, Vincent; Terra, Alexis; Ogea, Mathieu; Ciattaglia, Emanuela; Walker, Christopher

    2009-01-01

    Most of ITER diagnostic systems are integrated in port plugs, which are water cooled stainless steel structures inserted into the vacuum vessel ports. The port plug must provide basic functions such as neutron and gamma shielding, supporting the first wall armour (BSM), closing the vacuum vessel ports, while supporting the diagnostic equipments. ITER diagnostic port plug must resist a severe environment like high temperature due to neutron interaction with the structures and high electromechanical loading during disruptions events. CEA has contributed to the design and integration tasks in the frame of the representative equatorial port plug EQ no. 01, in particular on the engineering, structural and thermal finite element analysis. These detailed analyses have highlighted some design issues which were worked out through different solutions. This paper contains a description of the engineering activities performed such as: -The static mechanical calculations of the top plate closure system under disruption load. -The static mechanical calculations of the BSM attachment to the port plug. These two first studies led to design changes proposals which significantly improved the behaviour of the structures but also showed that the safety margin with respect to design limits is quite low. -The design of a Diagnostic Shield Module (DSM) integrated inside the port plug and a proposition of attachment scheme, with respect to disruption loads. The manufacturing of the DSM has been taken into account, as well as diagnostic integration inside the structure and maintenance aspects. -The thermal assessment of the port plug under neutronic load during normal operation, with the optimization of the cooling system. The maximum temperature calculated in normal operation has been reduced from 900 deg. C to less than 400 deg. C in the front plate; and the cooling arrangement at the back of the port plug has been simplified without important temperature increase.

  19. Engineering activities on the ITER representative diagnostic equatorial port plug

    Energy Technology Data Exchange (ETDEWEB)

    Meunier, L. [Association Euratom CEA, CEA/DSM/IRFM (France)], E-mail: lmeunier@cea.fr; Doceul, L.; Salasca, S.; Martins, J.-P.; Jullien, F.; Dechelle, Christian; Bidaud, Pierre; Pilard, Vincent; Terra, Alexis; Ogea, Mathieu [Association Euratom CEA, CEA/DSM/IRFM (France); Ciattaglia, Emanuela [EFDA CSU, Garching (Germany); Walker, Christopher [ITER International Organisation (France)

    2009-06-15

    Most of ITER diagnostic systems are integrated in port plugs, which are water cooled stainless steel structures inserted into the vacuum vessel ports. The port plug must provide basic functions such as neutron and gamma shielding, supporting the first wall armour (BSM), closing the vacuum vessel ports, while supporting the diagnostic equipments. ITER diagnostic port plug must resist a severe environment like high temperature due to neutron interaction with the structures and high electromechanical loading during disruptions events. CEA has contributed to the design and integration tasks in the frame of the representative equatorial port plug EQ no. 01, in particular on the engineering, structural and thermal finite element analysis. These detailed analyses have highlighted some design issues which were worked out through different solutions. This paper contains a description of the engineering activities performed such as: -The static mechanical calculations of the top plate closure system under disruption load. -The static mechanical calculations of the BSM attachment to the port plug. These two first studies led to design changes proposals which significantly improved the behaviour of the structures but also showed that the safety margin with respect to design limits is quite low. -The design of a Diagnostic Shield Module (DSM) integrated inside the port plug and a proposition of attachment scheme, with respect to disruption loads. The manufacturing of the DSM has been taken into account, as well as diagnostic integration inside the structure and maintenance aspects. -The thermal assessment of the port plug under neutronic load during normal operation, with the optimization of the cooling system. The maximum temperature calculated in normal operation has been reduced from 900 deg. C to less than 400 deg. C in the front plate; and the cooling arrangement at the back of the port plug has been simplified without important temperature increase.

  20. Generic Diagnostic Port Integration for the Equatorial Port Plug of ITER

    International Nuclear Information System (INIS)

    Doceul, L.; Chappuis, Ph.; Portafaix, Ch.; Guillaume, T.; Bruyere, Ch.; Walker, Ch.; Ingesson, Ch.; Ciattaglia, E.; Salasca, S.; Eric, T.

    2006-01-01

    ITER requires an extensive set of diagnostic systems to provide several key functions such as protection of the device, input to plasma control systems and evaluation of the plasma performance. Most of these diagnostics system are to be integrated in port plugs, which are water cooled stainless steel structures (approximately: 50 t, 2 m x 2 m x 4 m) inserted into the vacuum-vessel ports. The port plug must perform basic functions such as providing neutron and gamma shielding, supporting the first wall armour and shielding blanket material, closing the vacuum vessel ports, supporting the diagnostic equipment (within the primary vacuum, on the primary vacuum boundary and in the port interspace). CEA (Commissariat l'Energie Atomique) has contributed to the engineering activities on the port plugs and has more particularly focused on the design and diagnostic integration in the representative equatorial port plug EQ01. The specific CEA contributions were to perform the general engineering, structural and thermal analysis. These detailed analysis have highlighted some design issues which were worked out through different solutions. This paper will contain the description of the engineering activities performed such as: - The conceptual design of the EQ01 and the associated diagnostics, such as the visible and infrared optical diagnostic, - The static mechanical calculations, taking into account the electromagnetic loads occurring during fast transient plasma events, - The dynamic calculation constituted of modal and transient analysis under the same electromagnetic loads to estimate the dynamic amplification factor due to the resonance phenomenon, - The thermal assessment under the neutronic load of the water-cooled stainless steel structure, - The seismic response of the port plug inside the vacuum vessel, taking into account the ground spectra and soil conditions in the Cadarache site. (author)

  1. Conceptual design on structure and cooling channel of ITER upper port plug

    International Nuclear Information System (INIS)

    Pak, Sunil; Lee, Hyeon Gon; Jung, Ki Jung; Walker, C.; Kim, Doo Gi; Choi, Kwang Suk; Eo, Sang Gon

    2007-01-01

    This study has performed conceptual design on structure and cooling channel for the upper port plug of the International Thermonuclear Experimental Reactor (ITER), in which electron cyclotron heating (ECH) launcher and various diagnostic modules will be installed with the same structure. There are twelve diagnostic plugs and four ECH plugs at the upper port in ITER Tokamak. The use of the same port plug structure is beneficial for installation of diagnostic modules and ECH launcher from the viewpoint of cost reduction and simple RH maintenance. The diagnostic modules have rectangular cross-section and ECH modules have trapezoidal crosssection with the lower part wider. Here was suggested the bolt-jointed common structure of inverted-U shape beam and bottom plate, where the diagnostic and ECH modules are installed onto the bottom plate and then the assembly is bolted to the inverted-U beam from the bottom. The common structure of Inverted-U type was evaluated by considering several aspects, such as installation, remote handling (RH) maintenance, cooling line connection, manufacturing, and structural stiffness. For the inverted-U port plug structure developed here, this paper proposed a network of water channel for cooling and baking. Pressurized water as working fluid has to be supplied into the whole port plug. It consists of the structure, diagnostic/shielding modules fixed onto the bottom plate, and the blanket shield module (BSM) attached to the front. The internal water ways for these three components were designed in the direction that would not only minimize the RH connections, flow restrictors, and the length of water-vacuum welding, but also make the welding reliable. Independent coolant loops were composed for three parts of the structure, BSM, and diagnostic/shielding modules with bottom plate. These loops, therefore, make it possible to perform the leakage test for each one separately. Finally hydraulic analysis has been performed with ANSYS in order to

  2. The remote handling compatibility analysis of the ITER generic upper port plug structure

    Energy Technology Data Exchange (ETDEWEB)

    Ronden, D.M.S., E-mail: d.m.s.ronden@differ.nl [FOM Institute DIFFER, P.O. Box 1207, 3430 BE Nieuwegein (Netherlands); Dammann, A. [ITER Organization, Route de Vinon sur Verdon, 13115 Saint Paul-lez-Durance (France); Elzendoorn, B. [FOM Institute DIFFER, P.O. Box 1207, 3430 BE Nieuwegein (Netherlands); Giacomin, T. [ITER Organization, Route de Vinon sur Verdon, 13115 Saint Paul-lez-Durance (France); Heemskerk, C. [Heemskerk Innovative Technology, Merelhof 2, 2172 HZ Sassenheim (Netherlands); Loesser, D. [Princeton Plasma Physics Laboratory, Princeton, NJ 08543-0451 (United States); Maquet, P. [ITER Organization, Route de Vinon sur Verdon, 13115 Saint Paul-lez-Durance (France); Oosterhout, J. van [FOM Institute DIFFER, P.O. Box 1207, 3430 BE Nieuwegein (Netherlands); Pak, S.; Pitcher, C.S.; Portales, M.; Proust, M.; Udintsev, V.S.; Walsh, M.J. [ITER Organization, Route de Vinon sur Verdon, 13115 Saint Paul-lez-Durance (France)

    2014-10-15

    Highlights: • We describe the remote handling compatibility of the ITER generic upper port plug. • Concepts are presented of specific design solutions to improve RH compatibility. • Simulation in VR of the GUPP DSM replacement indicates possible collisions. • Specific tooling concepts are proposed for GUPP handling equipment for the hot cell. - Abstract: The ITER diagnostics generic upper port plug (GUPP) is developed as a standardized design for all diagnostic upper port plugs, in which a variety of payloads can be mounted. Here, the remote handling compatibility analysis (RHCA) of the GUPP design is presented that was performed for the GUPP final design review. The analysis focuses mainly on the insertion and extraction procedure of the diagnostic shield module (DSM), a removable cassette that contains the diagnostic in-vessel components. It is foreseen that the DSM is a replaceable component – the procedure of which is to be performed inside the ITER hot cell facility (HCF), where the GUPP can be oriented in a vertical position. The DSM removal procedure in the HCF consists of removing locking pins, an M30 sized shoulder bolt and two electrical straps through the use of a dexterous manipulator, after which the DSM is lifted out of the GUPP by an overhead crane. For optimum access to its internals, the DSM is mounted in a handling device. The insertion of a new or refurbished DSM follows the reverse procedure. The RHCA shows that the GUPP design requires a moderate amount of changes to become fully compatible with RH maintenance requirements.

  3. The remote handling compatibility analysis of the ITER generic upper port plug structure

    International Nuclear Information System (INIS)

    Ronden, D.M.S.; Dammann, A.; Elzendoorn, B.; Giacomin, T.; Heemskerk, C.; Loesser, D.; Maquet, P.; Oosterhout, J. van; Pak, S.; Pitcher, C.S.; Portales, M.; Proust, M.; Udintsev, V.S.; Walsh, M.J.

    2014-01-01

    Highlights: • We describe the remote handling compatibility of the ITER generic upper port plug. • Concepts are presented of specific design solutions to improve RH compatibility. • Simulation in VR of the GUPP DSM replacement indicates possible collisions. • Specific tooling concepts are proposed for GUPP handling equipment for the hot cell. - Abstract: The ITER diagnostics generic upper port plug (GUPP) is developed as a standardized design for all diagnostic upper port plugs, in which a variety of payloads can be mounted. Here, the remote handling compatibility analysis (RHCA) of the GUPP design is presented that was performed for the GUPP final design review. The analysis focuses mainly on the insertion and extraction procedure of the diagnostic shield module (DSM), a removable cassette that contains the diagnostic in-vessel components. It is foreseen that the DSM is a replaceable component – the procedure of which is to be performed inside the ITER hot cell facility (HCF), where the GUPP can be oriented in a vertical position. The DSM removal procedure in the HCF consists of removing locking pins, an M30 sized shoulder bolt and two electrical straps through the use of a dexterous manipulator, after which the DSM is lifted out of the GUPP by an overhead crane. For optimum access to its internals, the DSM is mounted in a handling device. The insertion of a new or refurbished DSM follows the reverse procedure. The RHCA shows that the GUPP design requires a moderate amount of changes to become fully compatible with RH maintenance requirements

  4. Maintenance implications of critical components in ITER CXRS upper port plug design

    International Nuclear Information System (INIS)

    Koning, Jarich; Jaspers, Roger; Doornink, Jan; Ouwehand, Bernard; Klinkhamer, Friso; Snijders, Bart; Sadakov, Sergey; Heemskerk, Cock

    2009-01-01

    Already in the early phase of a design for ITER, the maintenance aspects should be taken into account, since they might have serious implications. This paper presents the arguments in support of the case for the maintainability of the design, notably if this maintenance is to be performed by advanced remote methods. This structure is compliant to the evolving maintenance strategy of ITER. Initial results of a Failure Mode Effects and Criticality Analysis (FMECA) and a development risk analysis for the ITER upper port plug no. 3, housing the Charge Exchange Recombination Spectroscopy (CXRS) diagnostic, are employed for the definition of the maintenance strategy. The CXRS upper port plug is essentially an optical system which transfers visible light from the plasma into a fiber bundle. The most critical component in this path is the first mirror (M1) whose reflectivity degrades during operation due to deposition and/or erosion dominated effects. Amongst other measures to mitigate these effects, the strategy is to allow for a replacement of this mirror. Therefore it is mounted on a retractable central tube. The main purpose of this tube is to make frequent replacements possible without hindering operation. The maintenance method in terms of time, geometry and spare part policy has a large impact on cost of the system and time usage in the hot cell. Replacement of the tube under vacuum and magnetic field seems infeasible due to the operational risk involved. The preferred solution is to have a spare tube available which is replaced in parallel with other maintenance operations on the vessel, as to avoid any interference in the hot cell with the shutdown scheduling. This avoids having to refurbish a full port plug and also allows for a more frequent replacement of M1, as we can replace the mirror anytime the vacuum vessel is vented, estimated to be once a year.

  5. Structural Analysis for an Upper Port of the ITER Vacuum Vessel

    International Nuclear Information System (INIS)

    Yun-Seok Hong; Kwon, T. K.; Ahn, H. J.; Kim, Y.K.; Lee, C.D.

    2006-01-01

    The ITER vacuum vessel (VV) has numerous openings for the port structures including upper, equatorial, and lower ports used for equipment installation, utility feed through, vacuum pumping, and access into the vessel for maintenance. Every upper port, slanted upward slightly, has a trapezoidal/rectangular cross-section and consists of a port stub, a stub extension and a port extension with a connecting duct. To investigate the structural integrity and to increase the structural reliability of the VV and ports, the structural analyses of the upper port structure have been performed. The global structural analysis of the upper port with the in-port components has been carried out. The local analyses of a tangential key, an upper port flange, a connecting duct and a sealing unit have been performed. The design loads are dead weight, normal and abnormal pressure load, electromagnetic load, and seismic load in consideration of the dynamic amplification factors. The stress analyses were performed in a nonlinear elastic approach taking into account the contact surface between port extension flange and port plug flange. Two advanced designs from the ITER international team have been reviewed. To verify the strength of the reinforcing ribs for the connecting duct and of the fastening/sealing units, the local analyses utilizing the sub-modeling technique have been performed. The ASME code and the ITER design criteria were applied for the evaluation of the structural analysis results from the global and local analyses. The clearance between a port and a plug to accommodate the plug deformation has been assessed. The upper port flange based on the original design could withstand design loads, but there could be a gap on the flange surface under the design condition. The modified flange design, which is under the bolt friction only without tangential key was proposed. The deflection of the plug for an advanced design with a removable flange is higher than that for the original

  6. Radiation level analysis for the port cell of the ITER electron cyclotron-heating upper launcher

    Energy Technology Data Exchange (ETDEWEB)

    Weinhorst, Bastian, E-mail: bastian.weinhorst@kit.edu [KIT, Institute for Neutron Physics and Reactor Technology, Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen (Germany); Fischer, Ulrich; Lu, Lei [KIT, Institute for Neutron Physics and Reactor Technology, Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen (Germany); Strauss, Dirk; Spaeh, Peter; Scherer, Theo [KIT, Institute for Applied Materials, Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen (Germany); Leichtle, Dieter [F4E, Analysis & Codes/Technical Support Services, Josep Pla 2, Torres Diagonal Litoral B3, 08019 Barcelona (Spain)

    2016-11-01

    Highlights: • First detailed neutronic modelling of the ECHUL port cell with ECHUL equipment (including beam lines with diamond windows, the beam lines mounting box, conduit boxes and rails). • Three different bioshield port plug configurations and two different neutron source configurations are investigated. • Radiation Levels are calculated in the port cell, focusing on the position of the diamond window. • The dose rate in the port cell is below the limit for maintenance in the port cell. • The radiation level at the diamond window is very low and should not influence its performance. - Abstract: The electron cyclotron-heating upper launcher (ECHUL) will be installed in four upper ports of the ITER tokamak thermonuclear fusion reactor. Each ECHUL is able to deposit 8 MW power into the plasma for plasma mode stabilization via microwave beam lines. An essential part of these beam lines are the diamond windows. They are located in the upper port cell behind the bioshield to reduce the radiation levels to a minimum. The paper describes the first detailed neutronic modelling of the ECHUL port cell with ECHUL equipment. The bioshield plug is modelled including passageways for the microwave beam lines, piping and cables looms as well as rails and openings for ventilation. The port cell is equipped with the beam lines including the diamond windows, the beam lines mounting box, conduit boxes and rails. The neutrons are transported into the port cell starting from a surface source in front of the bioshield. Neutronic results are obtained for radiation levels in the port cell at different positions, mainly focusing on the diamond windows position. It is shown that the radiation level is below the limit for maintenance in the port cell. The radiation level at the diamond window is very low and should not influence its performance.

  7. Upper extremity deep venous thrombosis after port insertion: What are the risk factors?

    Science.gov (United States)

    Tabatabaie, Omidreza; Kasumova, Gyulnara G; Kent, Tara S; Eskander, Mariam F; Fadayomi, Ayotunde B; Ng, Sing Chau; Critchlow, Jonathan F; Tawa, Nicholas E; Tseng, Jennifer F

    2017-08-01

    Totally implantable venous access devices (ports) are widely used, especially for cancer chemotherapy. Although their use has been associated with upper extremity deep venous thrombosis, the risk factors of upper extremity deep venous thrombosis in patients with a port are not studied adequately. The Healthcare Cost and Utilization Project's Florida State Ambulatory Surgery and Services Database was queried between 2007 and 2011 for patients who underwent outpatient port insertion, identified by Current Procedural Terminology code. Patients were followed in the State Ambulatory Surgery and Services Database, State Inpatient Database, and State Emergency Department Database for upper extremity deep venous thrombosis occurrence. The cohort was divided into a test cohort and a validation cohort based on the year of port placement. A multivariable logistic regression model was developed to identify risk factors for upper extremity deep venous thrombosis in patients with a port. The model then was tested on the validation cohort. Of the 51,049 patients in the derivation cohort, 926 (1.81%) developed an upper extremity deep venous thrombosis. On multivariate analysis, independently significant predictors of upper extremity deep venous thrombosis included age deep venous thrombosis (odds ratio = 1.77), all-cause 30-day revisit (odds ratio = 2.36), African American race (versus white; odds ratio = 1.86), and other nonwhite races (odds ratio = 1.35). Additionally, compared with genitourinary malignancies, patients with gastrointestinal (odds ratio = 1.55), metastatic (odds ratio = 1.76), and lung cancers (odds ratio = 1.68) had greater risks of developing an upper extremity deep venous thrombosis. This study identified major risk factors of upper extremity deep venous thrombosis. Further studies are needed to evaluate the appropriateness of thromboprophylaxis in patients at greater risk of upper extremity deep venous thrombosis. Copyright © 2017 Elsevier Inc

  8. Results of an integration study of a diagnostics port plug in ITER

    International Nuclear Information System (INIS)

    Salasca, Sophie; Cantone, Bruno; Grosman, André; Esposito, Basilio; Moro, Fabio; Morocco, Daniele; Villari, Rosaria; Angelone, Maurizio; Rincon, Esther; Hidalgo, Carlos; Nagy, Daniel; Kocsis, Gabor; Varela, Paulo; Porempovics, Gabor; Perrollaz, Guillaume; Patel, Kunal; Krivchenkov, Yuri; Walsh, Michael

    2013-01-01

    Highlights: ► An extensive study on the integration of diagnostics in a port plug of ITER has been performed. ► It has shown that the diagnostic performances could not be reached if their number was not decreased. ► A design of Diagnostic Shield Modules has been validated through mechanical and thermal analyses. ► These analyses have confirmed that the highest loads are concentrated in the vicinity of the plasma. -- Abstract: Diagnostics in ITER are mandatory to characterize the parameters of plasma and study its interactions with plasma-facing components. Diagnostics components in the vicinity of the plasma are supported by metallic structures called port plugs. At the tokamak mid-plane, these components are installed in port plugs through intermediate structures called drawers. Apart from hosting the diagnostics, the port plugs act as shielding against neutrons and gammas, in order to limit the nuclear loads in crucial components (such as diagnostics and superconducting coils) as well as the dose levels in the controlled zones of the tokamak. The radiation shielding function of the port plugs is ensured through an optimized mixture of heavy metallic materials and water, forming shielding blocks surrounding the diagnostics and called Diagnostic Shield Modules (DSMs). These DSMs constitute the rear part of the drawers (the front part being composed of the Diagnostic First Wall). This paper presents the main results of a study performed in Europe on the integration of a particular diagnostics port plug, the Equatorial Port Plug 1 (EPP1). The paper first provides the results of the EPP1 diagnostics integration analysis. In a second step it focuses on the design of the EPP1 DSMs and summarizes the major results of a thorough set of analyses aiming at studying the DSMs behaviour under different loads, suggesting recommendations to improve their current design

  9. ITER Upper Port Plug handling cask system assessment and design proposals

    NARCIS (Netherlands)

    Pustjens, J.; Friconneau, J.P.; Heemskerk, C.J.M.; Koning, J.F.; Martins, J.P.; Rosielle, P.C.J.N.; Steinbuch, M.

    2011-01-01

    The current design of the ITER cask for Upper Port Plugs has been evaluated. Careful reduction of the number of mechanical degrees of freedom is an opportunity to relax the tolerances in the design, resulting in cost reduction and reliability increase. A new kinematical design for the tractor module

  10. ITER Upper Port Plug Handling Cask System assessment and design proposals

    NARCIS (Netherlands)

    Pustjens, J.; Friconneau, J.P.; Heemskerk, C.J.M.; Koning, J.F.; Martins, J.P.; Rosielle, P.C.J.N.; Steinbuch, M.

    2010-01-01

    The current design of the ITER Cask for Upper Port Plugs (UPPs) has been evaluated. Careful reduction of the number of mechanical Degrees of Freedom is an opportunity to relax the tolerances in the design, resulting in cost reduction and reliability increase. A new kinematical design for the tractor

  11. Upper Gastro-Intestinal Endoscopy in Port Harcourt, Nigeria: An Audit

    African Journals Online (AJOL)

    Background: Accurate diagnosis of disease conditions using laboratory, imaging or endoscopic investigation is essential for appropriate treatment. There is paucity of data on upper GI endoscopy in Port-Harcourt. This audit of our early experience is intended to provide data on the pattern of endoscopy findings which is ...

  12. CEA engineering studies and integration of the ITER diagnostic port plugs

    International Nuclear Information System (INIS)

    Doceul, L.; Walker, C.; Ingesson, C.; Ciattaglia, E.; Chappuis, P.; Portafaix, C.; Salasca, S.; Thomas, E.; Tremblay, G.; Bruyere, C.

    2007-01-01

    Most of the ITER diagnostic system is integrated in port plugs, which are water cooled stainless steel structures inserted into the vacuum-vessel ports. The port plug must perform basic functions such as providing neutron and gamma shielding, supporting the first wall armour and shielding blanket material, closing the vacuum vessel ports, while supporting the diagnostic equipment. CEA has contributed to the engineering activities on the port plugs and has more particularly focused on the design and diagnostic integration in the representative equatorial port plug Eq no. 01. The specific CEA contributions have been the engineering, structural and thermal analysis. These detailed analyses have highlighted some design issues which were worked out through different solutions. This paper contains a description of the engineering activities performed such as: the conceptual design of the Eq no. 01 port plug, the static mechanical calculations, the dynamic calculation to estimate the dynamic amplification factor due to the resonance phenomenon, the thermal assessment under the neutronic load and the seismic response of the port plug inside the vacuum vessel

  13. CEA engineering studies and integration of the ITER diagnostic port plugs

    Energy Technology Data Exchange (ETDEWEB)

    Doceul, L. [Association Euratom-CEA sur la Fusion Controlee, Centre d' Etudes de Cadarache, F-13108 Saint-Paul-Lez-Durance Cedex (France)], E-mail: louis.doceul@cea.fr; Walker, C. [ITER International Team, Boltzmannstr. 2, D-85748 Garching bei Muenchen (Germany); Ingesson, C.; Ciattaglia, E. [EFDA CSU - Garching, Boltzmannstr. 2, D-85748 Garching bei Muenchen (Germany); Chappuis, P.; Portafaix, C.; Salasca, S.; Thomas, E.; Tremblay, G.; Bruyere, C. [Association Euratom-CEA sur la Fusion Controlee, Centre d' Etudes de Cadarache, F-13108 Saint-Paul-Lez-Durance Cedex (France)

    2007-10-15

    Most of the ITER diagnostic system is integrated in port plugs, which are water cooled stainless steel structures inserted into the vacuum-vessel ports. The port plug must perform basic functions such as providing neutron and gamma shielding, supporting the first wall armour and shielding blanket material, closing the vacuum vessel ports, while supporting the diagnostic equipment. CEA has contributed to the engineering activities on the port plugs and has more particularly focused on the design and diagnostic integration in the representative equatorial port plug Eq no. 01. The specific CEA contributions have been the engineering, structural and thermal analysis. These detailed analyses have highlighted some design issues which were worked out through different solutions. This paper contains a description of the engineering activities performed such as: the conceptual design of the Eq no. 01 port plug, the static mechanical calculations, the dynamic calculation to estimate the dynamic amplification factor due to the resonance phenomenon, the thermal assessment under the neutronic load and the seismic response of the port plug inside the vacuum vessel.

  14. The Front Steering Launcher Design for the ITER ECRH Upper Port

    International Nuclear Information System (INIS)

    Henderson, M A; Chavan, R; Heidinger, R; Nikkola, P; Ramponi, G; Saibene, G; Sanchez, F; Sauter, O; Serikov, A; Zohm, H

    2005-01-01

    The ECRH ITER upper port antenna's role is to stabilize the neoclassical tearing mode (NTM) on either the q = 2 or 3/2 rational flux surfaces, which requires a narrow current deposition profile (j CD ) over a wide range along the resonance surfaces. The width of j CD should be equivalent to the marginal island width to fully stabilise the NTM. Two antenna concepts are under consideration for the upper port launcher: front steering (FS) and remote steering (RS). The FS launcher decouples the steering and focusing aspects using a two mirror system (one focusing and one steering), achieving a wider steering range and higher current density for NTM stabilisation than required by ITER, offering a threefold increase in NTM stabilization efficiency over the RS launcher. The improved physics performance has motivated the further design study of the FS launcher aiming toward a build to print launcher. The present design is compatible with ≥2.0 MW CW operation and 8 beams per port plug. A frictionless backlashfree system is envisioned for the steering mechanism. An overview of the launcher design, the calculated physics performance and the possibility of using the upper port launcher for extended physics applications (beyond NTM stabilisation) are discussed

  15. Electromagnetic analysis of ITER diagnostic equatorial port plugs during plasma disruptions

    International Nuclear Information System (INIS)

    Zhai, Y.; Feder, R.; Brooks, A.; Ulrickson, M.; Pitcher, C.S.; Loesser, G.D.

    2013-01-01

    Highlights: ► Disruption loads on ITER diagnostic equatorial port plugs are extracted. ► Upward major disruption produces the largest radial moment and radial force on diagnostic first walls and diagnostic shield modules. ► Large eddy currents on supporting rails, keys and water pipes are observed during disruption. -- Abstract: ITER diagnostic port plugs perform many functions including structural support of diagnostic systems under high electromagnetic loads while allowing for diagnostic access to the plasma. The design of diagnostic equatorial port plugs (EPP) are largely driven by electromagnetic loads and associate responses of EPP structure during plasma disruptions and VDEs. This paper summarizes results of transient electromagnetic analysis using Opera 3d in support of the design activities for ITER diagnostic EPP. A complete distribution of disruption loads on the diagnostic first walls (DFWs), diagnostic shield modules (DSMs) and the EPP structure, as well as impact on the system design integration due to electrical contact among various EPP structural components are discussed

  16. Final design of the generic equatorial port plug structure for ITER diagnostic systems

    International Nuclear Information System (INIS)

    Udintsev, V.S.; Maquet, P.; Alexandrov, E.; Casal, N.; Cuenca, D.; Drevon, J.-M.; Feder, R.; Friconneau, J.P.; Giacomin, T.; Guirao, J.; Iglesias, S.; Josseaume, F.; Levesy, B.; Loesser, D.; Ordieres, J.; Quinn, E.; Pak, S.; Penot, C.; Pitcher, C.S.; Portalès, M.

    2015-01-01

    The Diagnostic Generic Equatorial Port Plug (GEPP) is designed to be common to all equatorial port-based diagnostic systems. It is designed to survive throughout the lifetime of ITER for 20 years, 30,000 discharges, and 3000 disruptions. The EPP structure dimensions (without Diagnostic First Walls and Diagnostic Shield Modules) are L2.9 × W1.9 × H2.4 m"3. The length of the fully integrated EPP is 3174 mm. The weight of the EPP structure is about 15 t, whereas the total weight of the integrated EPP may be up to 45 t. The EPP structure provides a flexible platform for a variety of diagnostics. The Diagnostic Shield Module assemblies, or drawers, allow a modular approach with respect to diagnostic integration and maintenance. In the nuclear phase of ITER operations, they will be remotely inserted into the EPP structure in the Hot Cell Facility. The port plug structure must also contribute to the nuclear shielding, or plugging, of the port and further contain circulated water to allow cooling during operation and heating during bake-out. The Final Design of the GEPP has been successfully passed in late 2013 and is now heading toward manufacturing. The final design of the GEPP includes interfaces, manufacturing, R&D, operation and maintenance, load cases and analysis of failure modes.

  17. Analysis of welding distortion due to narrow-gap welding of upper port plug

    International Nuclear Information System (INIS)

    Biswas, Pankaj; Mandal, N.R.; Vasu, Parameswaran; Padasalag, Shrishail B.

    2010-01-01

    Narrow-gap welding is a low distortion welding process. This process allows very thick plates to be joined using fewer weld passes as compared to conventional V-groove or double V-groove welding. In case of narrow-gap arc welding as the heat input and weld volume is low, it reduces thermal stress leading to reduction of both residual stress and distortion. In this present study the effect of narrow-gap welding was studied on fabrication of a scaled down port plug in the form of a trapezoidal box made of 10 mm thick mild steel (MS) plates using gas tungsten arc welding (GTAW). Inherent strain method was used for numerical prediction of resulting distortions. The numerical results compared well with that of the experimentally measured distortion. The validated numerical scheme was used for prediction of weld induced distortion due to narrow-gap welding of full scale upper port plug made of 60 mm thick SS316LN material as is proposed for use in ITER project. It was observed that it is feasible to fabricate the said port plug keeping the distortions minimum within about 7 mm using GTAW for root pass welding followed by SMAW for filler runs.

  18. Diagnostic distribution of non-traumatic upper limb disorders

    DEFF Research Database (Denmark)

    Laursen, Lise H; Sjøgaard, Gisela; Hagert, C G

    2007-01-01

    BACKGROUND: Upper limb disorders (ULDs) are common, and so are the difficulties in specific diagnoses of these disorders. Prior studies have shed light on the nerves in the diagnostic approach beside disorders related to muscles, tendons and joints (MCDs). OBJECTIVE: The study aimed to compare th...

  19. A modified method using a two-port approach for accessing the hilar vasculature without transferring an endostapler from camera port to utility port during thoracoscopic right upper lobectomy.

    Science.gov (United States)

    Jiao, W; Zhao, Y; Xuan, Y; Wang, M

    2015-02-01

    For thoracoscopic upper lobectomies, most cutting endostaplers must be inserted through the camera port when using a two-port approach. Access to the hilar vasculature through only the utility port remains a challenge. In this study, we describe a procedure to access the hilar vasculature without transferring the endostapler site during a thoracoscopic right upper lobectomy. A 2.5-cm utility anterior incision was made in the fourth intercostal space. The posterior mediastinal visceral pleura were dissected to expose the posterior portion of the right upper bronchus and the anterior trunk of the right pulmonary artery. The pleura over the right hilar vasculature were then peeled with an electrocoagulation hook. The anterior trunk of the right pulmonary artery was then transected with a cutting endostapler through the utility port firstly. This crucial maneuver allowed the endostapler access to the right upper lobe pulmonary vein. The hilar structures were then easily handled in turn. This novel technique was performed successfully in 32 patients, with no perioperative deaths. The average operation time was 120.6 min (range 75-180 min). This novel technique permits effective control of the hilar vessels through the utility port, enabling simple, safe, quick and effective resection.

  20. Analysis of the ITER ECH Upper Port Launcher remote maintenance using virtual reality

    International Nuclear Information System (INIS)

    Elzendoorn, Ben; de Baar, Marco; Chavan, Rene; Goodman, Timothy; Heemskerk, Cock; Heidinger, Roland; Kleefeldt, Klaus; Koning, Jarich; Sanders, Stephen; Spaeh, Peter; Strauss, Dirk; Verhoeven, Toon; Vreede, Fred de

    2009-01-01

    All ITER sub-systems of remote handling (RH) classes 1 and 2 have to be remotely maintainable. The maintenance strategy for these components has to ensure system availability after failure or scheduled maintenance. This paper shows how virtual reality (VR) simulation can be used as a tool to analyze the maintenance process, to predict the mean time to repair and to ensure the RH compatibility of one ITER sub-system, the Upper Port Launcher (UPL) . Special emphasis is put on the development of RH procedures and the identification of tooling requirements. The possibility to simulate RH logistics and repair actions in an early stage of the design process allows for the identification of those maintenance actions that require dedicated tests in the Launcher Handling Test Facility at Karlsruhe. The VR analysis, together with dedicated mock-up tests will demonstrate the RH compatibility of the UPL plug, provide input to the design of the Port Plug maintenance area in the ITER Hot Cell, and support the development of RH maintenance tooling.

  1. Mechanical design aspects of a "Long-Waveguide" version of the remote steering ECRH upper port launcher for ITER

    NARCIS (Netherlands)

    Ronden, D. M. S.; van den Berg, M.; Bongers, W. A.; Elzendoorn, B. S. Q.; M. F. Graswinckel,; Lamers, B.; Van Nigtevecht, K.; Verhoeven, A. G. A.; Henderson, M. A.

    2008-01-01

    The current status of the mechanical design of the remote steering electron cyclotron resonance heating upper port launching system for ITER is presented. Although an alternative front steering launcher has now been selected as the reference design for ITER, the development of a remote steering

  2. Risk mitigation strategy for the ITER electron cyclotron upper port launcher

    International Nuclear Information System (INIS)

    Goede, A.P.H.; Bongers, W.A.; Elzendoorn, B.S.Q.; Graswinckel, M.F.; Baar, M.R. de

    2010-01-01

    A basic requirement for ITER equipment to meet is a high level of reliability, because ITER operation time is precious and radioactive operation leaves limited scope for repair. In order to reduce the risk of failure during ITER operation an effective risk mitigation strategy is necessary. This paper presents such strategy for the ITER electron cyclotron upper port launcher (ECUPL). A preliminary ECUPL risk analysis identifies possible failure modes. A probabilistic risk assessment quantifies the risk of failure using a 4 x 4 impact-likelihood matrix. Impact is quantified through technical, cost and schedule elements. Likelihood depends on the risk mitigation strategy adopted. A cost benefit analysis determines the most cost effective risk mitigation strategy. An essential element in risk mitigation is the testing of equipment prior to installation on the ITER machine. This paper argues the need for low- and highpower millimetre wave tests carried out on the fully assembled ECUPL. It presents a conceptual design for a dedicated on-site test bed that can handle 2 of 8 microwave beams at 2 MW long pulse operation.

  3. A Frictionless Steering Mechanism for the Front Steering ECCD ITER Upper Port Launcher

    International Nuclear Information System (INIS)

    Chavan, R; Henderson, M A; Sanchez, F

    2005-01-01

    A FS launcher is being designed for the ITER upper port, which offers enhanced physics performance over the RS launcher. A two mirror system is used to decouple the focusing and steering aspects of the launcher and provide a relatively small beam waist ( 1.6 m from the steering mirror). The resulting NTM stabilization efficiency (maximum CD density divided by the local bootstrap current >1.6) is above marginal for the q = 2 and 3/2 rational flux surfaces of the relevant ITER equilibria (scenarios 2, 3a and 5) and a factor of ∼3 relative to an equivalent RS launcher. The performance of the FS launcher strongly depends on the reliability of the steering mechanism, which is used to rotate the plasma facing steering mirror. CRPP has designed a frictionless steering mechanism assembled in a compact cartridge capable of up to ±10 deg. rotation (corresponding to a poloidal steering range of up to ±20 deg. for the microwave beam around a fixed axis of rotation) that offers a high operation reliability despite the close proximity to the thermal and neutron flux coming from the ITER plasma

  4. Incidence of Central Vein Stenosis and Occlusion Following Upper Extremity PICC and Port Placement

    International Nuclear Information System (INIS)

    Gonsalves, Carin F.; Eschelman, David J.; Sullivan, Kevin L.; DuBois, Nancy; Bonn, Joseph

    2003-01-01

    The purpose of this study was to determine the incidence of central vein stenosis and occlusion following upper extremity placement of peripherally inserted central venous catheters(PICCs) and venous ports. One hundred fifty-four patients who underwent venography of the ipsilateral central veins prior to initial and subsequent venous access device insertion were retrospectively identified. All follow-up venograms were interpreted at the time of catheter placement by one interventional radiologist over a 5-year period and compared to the findings on initial venography. For patients with central vein abnormalities, hospital and home infusion service records and radiology reports were reviewed to determine catheter dwelltime and potential alternative etiologies of central vein stenosis or occlusion. The effect of catheter caliber and dwell time on development of central vein abnormalities was evaluated. Venography performed prior to initial catheter placement showed that 150 patients had normal central veins. Three patients had central vein stenosis, and one had central vein occlusion. Subsequent venograms (n = 154)at the time of additional venous access device placement demonstrated 8 patients with occlusions and 10 with stenoses. Three of the 18 patients with abnormal follow-up venograms were found to have potential alternative causes of central vein abnormalities. Excluding these 3 patients and the 4 patients with abnormal initial venograms, a 7% incidence of central vein stenosis or occlusion was found in patients with prior indwelling catheters and normal initial venograms. Catheter caliber showed no effect on the subsequent development of central vein abnormalities. Patients who developed new or worsened central vein stenosis or occlusion had significantly (p =0.03) longer catheter dwell times than patients without central vein abnormalities. New central vein stenosis or occlusion occurred in 7% of patients following upper arm placement of venous access devices

  5. 77 FR 40518 - Swim Events in the Captain of the Port New York Zone; Hudson River, East River, Upper New York...

    Science.gov (United States)

    2012-07-10

    ... 1625-AA00 Swim Events in the Captain of the Port New York Zone; Hudson River, East River, Upper New York Bay, Lower New York Bay; New York, NY ACTION: Final rule. SUMMARY: The Coast Guard is establishing seven temporary safety zones for swim events within the Captain of the Port (COTP) New York Zone. These...

  6. A prospective study of risk for Sturge-Weber syndrome in children with upper facial port-wine stain.

    Science.gov (United States)

    Dutkiewicz, Anne-Sophie; Ezzedine, Khaled; Mazereeuw-Hautier, Juliette; Lacour, Jean-Philippe; Barbarot, Sébastien; Vabres, Pierre; Miquel, Juliette; Balguerie, Xavier; Martin, Ludovic; Boralevi, Franck; Bessou, Pierre; Chateil, Jean-François; Léauté-Labrèze, Christine

    2015-03-01

    Upper facial port-wine stain (PWS) is a feature of Sturge-Weber syndrome (SWS). Recent studies suggest that the distribution of the PWS corresponds to genetic mosaicism rather than to trigeminal nerve impairment. We sought to refine the cutaneous distribution of upper facial PWS at risk for SWS. This was a prospective multicenter study of consecutive cases of upper facial PWS larger than 1 cm² located in the ophthalmic division of trigeminal nerve distribution in infants aged less than 1 year, seen in 8 French pediatric dermatology departments between 2006 and 2012. Clinical data, magnetic resonance imaging, and photographs were systematically collected and studied. PWS were classified into 6 distinct patterns. In all, 66 patients were included. Eleven presented with SWS (magnetic resonance imaging signs and seizure). Four additional infants had suspected SWS without neurologic manifestations. Hemifacial (odds ratio 7.7, P = .003) and median (odds ratio 17.08, P = .008) PWS patterns were found to be at high risk for SWS. A nonmedian linear pattern was not associated with SWS. Small number of patients translated to limited power of the study. Specific PWS distribution patterns are associated with an increased risk of SWS. These PWS patterns conform to areas of somatic mosaicism. Terminology stipulating ophthalmic division of trigeminal nerve territory involvement in SWS should be abandoned. Copyright © 2014 American Academy of Dermatology, Inc. Published by Elsevier Inc. All rights reserved.

  7. The use of the long modular diagnostics shield module to mitigate shutdown dose rates in the ITER diagnostics equatorial ports

    Science.gov (United States)

    Juárez, R.; Guirao, J.; Kolsek, A.; Lopez, A.; Pedroche, G.; Bertalot, L.; Udintsev, V. S.; Walsh, M. J.; Sauvan, P.; Sanz, J.

    2018-05-01

    The ITER equatorial port plugs are submitted to a drained weight limit of 45 T. This limitation can conflict with their radiation shielding demands, although some weight margin is being discussed. The port interspaces are subject to a shutdown dose rate limit of 100 µSv h‑1 after 106 s of cooling time. To meet it, the port plugs must show a neutron flux attenuation comparable to their neighborhood, despite considering penetrations to host systems. Most of this task relies on the drawer shield module (DSM). In this work, two DSM concepts are analyzed with this perspective: the box-based DSM and the modular DSM. Regardless the penetrations, the box-based DSM leads to unsatisfactory port plugs to meet both weight and SDDR requirements. On the contrary, the modular DSM shows a performance which allows for the adoption of such DSM concept, or equivalent, a port may comply with both requirements at the same time, provided the penetrations are well designed.

  8. Gastric volvulus following diagnostic upper gastrointestinal endoscopy: a rare complication.

    Science.gov (United States)

    Karthikeyan, Vilvapathy Senguttuvan; Sistla, Sarath Chandra; Ram, Duvuru; Rajkumar, Nagarajan

    2014-02-10

    Esophagogastroduodenoscopy (EGD) is a commonly used, safe diagnostic modality for evaluation of epigastric pain and rarely its major complications include perforation, haemorrhage, dysrhythmias and death. Gastric volvulus has been reported to complicate percutaneous endoscopic gastrostomy but its occurrence after diagnostic EGD has not yet been reported in literature. The successful management relies on prompt diagnosis and gastric untwisting, decompression and gastropexy or gastrectomy in full thickness necrosis of the stomach wall. A 38-year-old woman presented with epigastric pain and EGD showed pangastritis. Immediately after EGD she developed increased severity of pain, vomiting and abdominal distension. Emergency laparotomy carried out for peritoneal signs revealed eventration of left hemidiaphragm with the stomach twisted anticlockwise in the longitudinal axis. After gastric decompression and untwisting of volvulus, anterior gastropexy and gastrostomy was carried out. Hence, we report this rare complication of diagnostic endoscopy and review the existing literature on the management.

  9. The radiation analyses of ITER lower ports

    International Nuclear Information System (INIS)

    Petrizzi, L.; Brolatti, G.; Martin, A.; Loughlin, M.; Moro, F.; Villari, R.

    2010-01-01

    The ITER Vacuum Vessel has upper, equatorial, and lower ports used for equipment installation, diagnostics, heating and current drive systems, cryo-vacuum pumping, and access inside the vessel for maintenance. At the level of the divertor, the nine lower ports for remote handling, cryo-vacuum pumping and diagnostic are inclined downwards and toroidally located each every 40 o . The cryopump port has additionally a branch to allocate a second cryopump. The ports, as openings in the Vacuum Vessel, permit radiation streaming out of the vessel which affects the heating in the components in the outer regions of the machine inside and outside the ports. Safety concerns are also raised with respect to the dose after shutdown at the cryostat behind the ports: in such zones the radiation dose level must be kept below the regulatory limit to allow personnel access for maintenance purposes. Neutronic analyses have been required to qualify the ITER project related to the lower ports. A 3-D model was used to take into account full details of the ports and the lower machine surroundings. MCNP version 5 1.40 has been used with the FENDL 2.1 nuclear data library. The ITER 40 o model distributed by the ITER Organization was developed in the lower part to include the relevant details. The results of a first analysis, focused on cryopump system only, were recently published. In this paper more complete data on the cryopump port and analysis for the remote handling port and the diagnostic rack are presented; the results of both analyses give a complete map of the radiation loads in the outer divertor ports. Nuclear heating, dpa, tritium production, and dose rates after shutdown are provided and the implications for the design are discussed.

  10. Infrared tomography for diagnostic imaging of port wine stain blood vessels

    Energy Technology Data Exchange (ETDEWEB)

    Goodman, D. [Lawrence Livermore National Lab., CA (United States)

    1994-11-15

    The objective of this work is the development of Infrared Tomography (IRT) for detecting and characterizing subsurface chromophores in human skin. Characterization of cutaneous chromophores is crucial for advances in the laser treatment of pigmented lesions (e.g., port wine stain birthmarks and tatoos). Infrared tomography (IRT) uses a fast infrared focal plane array (IR-FPA) to detect temperature rises in a substrate induced by pulsed radiation. A pulsed laser is used to produce transient heating of an object. The temperature rise, due to the optical absorption of the pulsed laser light, creates an increase in infrared emission which is measured by the IR-FPA. Although the application of IRT to image subsurface cracks due to metal fatigue is a topic of great interest in the aircraft industry, the application to image subsurface chromophores in biological materials is novel. We present an image recovery method based on a constrained conjugate gradient algorithm that has obtained the first ever high quality images of port wine blood vessels.

  11. Fracture mechanics analysis approach to assess structural integrity of the first confinement boundaries in ITER Generic Upper Port Plug structure

    Energy Technology Data Exchange (ETDEWEB)

    Guirao, Julio, E-mail: julio@natec-ingenieros.com [Numerical Analysis Technologies S.L. (NATEC), Gijon (Spain); Iglesias, Silvia; Vacas, Christian; Udintsev, Victor [CHD, Diagnostic Division, ITER Organization, Route de Vinon-sur-Verdon, CS 90 046, 13067 St. Paul Lez Durance Cedex (France); Pak, Sunil [Diagnostic and Control Team, National Fusion Research Institute, Daejeon (Korea, Republic of); Maquet, Philippe [CHD, Diagnostic Division, ITER Organization, Route de Vinon-sur-Verdon, CS 90 046, 13067 St. Paul Lez Durance Cedex (France); Rodriguez, Eduardo; Roces, Jorge [Department of Construction and Manufacturing Engineering, University of Oviedo, Gijon (Spain)

    2015-10-15

    Highlights: • A parametric submodel of the spot under study is developed. • The associated macro has the capability to successively re-build the submodel implementing the crack with the geometry of the updated crack front as a function of the predicted increments of length in the apexes of the crack from the calculated stress intensity factor at the crack front. • The analysis incorporates the crack behavior model to predict the evolution of the postulated defect under the application of the different transients. • The analysis is based on the Elasto-Plastic Fracture Mechanics (EPFM) theory to account for the ductility of the materials (316LN type stainless steel). - Abstract: This paper demonstrates structural integrity of the first confinement boundary in Generic Upper Port Plug structures against cracking during service. This constitutes part of the justification to demonstrate that the non-aggression to the confinement barrier requirement may be compatible with the absent of a specific in-service inspections (ISI) program in the trapezoidal section. Since the component will be subjected to 100% volumetric inspections it can be assumed that no defects below the threshold of applied Nondestructive Evaluation techniques will be present before its commissioning. Cracks during service would be associated to defects under Code acceptance limit. This limit can be reasonably taken as 2 mm. Using elastic–plastic fracture mechanics an initial defect is postulated at the worst location in terms of probability and impact on the confinement boundary. Its evolution is simulated through finite element analysis and final dimension at the end of service is estimated. Applying the procedures in RCC-MR 2007 (App-16) the stability of the crack is assessed. As relative high safety margin was achieved, a complementary assessment postulating an initial defect of 6 mm was also conducted. New margin calculated provides a more robust design.

  12. On the theoretical–numerical study of the ITER Upper Port Plug structure hydraulic behaviour under steady state and draining and drying transient conditions

    International Nuclear Information System (INIS)

    Di Maio, P.A.; Paradiso, D.; Dell’Orco, G.; Pitcher, C.S.; Kalish, M.

    2011-01-01

    Highlights: ► UPP TS hydraulic behaviour has been investigated under steady state and D and D transient conditions. ► A thermal–hydraulic system code has been adopted and a UPP TS model has been set-up and validated against results of steady state CFD analyses. ► The TS steady state hydraulic characteristic functions have been derived for two coolant flow paths showing that right plate inlet one is the most promising. ► Draining simulations indicate that the 4 MPa injection pressure is high enough to drain almost completely the circuit in a reasonable time (∼6 s). ► Results indicate that right plate inlet flow path allows the TS complete draining, eliminating the need for the drying procedure. - Abstract: The ITER diagnostic Upper Port Plug (UPP) is a water-cooled stainless steel structure aimed to integrate within vacuum vessel the plasma diagnostic systems, shielding them from neutron and photon irradiation. Due to the very intense heat loads expected, a proper cooling circuit has been designed to ensure an adequate UPP cooling with an acceptable thermal rise and an unduly high pumping power and to perform its draining and drying procedure by injection of pressurized nitrogen. A theoretical research activity has been launched at the Department of Nuclear Engineering of the University of Palermo aiming to investigate the hydraulic behaviour of the UPP Trapezoid Section cooling circuit under steady state conditions and during its draining and drying transient procedure. The research activity has been performed following a theoretical–computational approach and adopting the RELAP5 thermal–hydraulic system code. The Trapezoid Section cooling circuit characteristic functions have been derived under steady state conditions at various coolant temperatures for both the coolant flow paths at the present under consideration for this circuit. The distributions of coolant mass flow rates along the channels of the cooling circuit have been calculated too

  13. Imaging diagnostics of ethanol port fuel injection sprays for automobile engine applications

    International Nuclear Information System (INIS)

    Padala, Srinivas; Le, Minh Khoi; Kook, Sanghoon; Hawkes, Evatt R.

    2013-01-01

    This paper presents characteristics of ethanol sprays at port fuel injection (PFI) conditions with variations in injection and ambient parameters. Details of temporal and spatial development of ethanol PFI sprays are studied using Mie-scattering and high-speed shadowgraph imaging techniques. Momentum flux-based injection rate measurement is also performed. The influences of fuel flow-rate, injection duration, and ambient air cross-flow are of particular interest in an effort to understand ethanol PFI spray characteristics that are relevant to automobile engines. For comparison purposes, the results from gasoline fuel are also presented. Ethanol flow-rate effects are studied using two injectors with different nozzle-hole sizes at a fixed injection pressure. From the experiments, it was found that the actual injection duration was longer for the higher flow-rate injector although an electronic pulse width was fixed. This was due to an extended delay in the injector needle closing as the flow resistance against the needle was increased for the high flow-rate injector. For liquid droplets, the larger hole size of the higher flow-rate injector caused a higher mean droplet diameter and higher number of droplets. Injection duration was also varied to study transient spray behaviour: short-injection sprays with the end-of-injection transient dominating the overall spray development were compared to long, steady-injection sprays. From Mie-scattering images, the number of droplets and mean droplet diameter were found to be less for the short injection sprays. Detailed analysis using an axial profile of the number of droplets and mean droplet diameter suggested that the observed trends were a result of increased evaporation rate near the nozzle after the end of injection. This was consistent with shadowgraph images showing no liquid regions but only the vapour-phase fuel near the nozzle. Under the influence of ambient air cross-flow, both mean droplet diameter and number of

  14. The comparison of upper endoscopy and scintigraphy results in the diagnostics of duodenogastric reflux

    International Nuclear Information System (INIS)

    Leja, M.; Lejnieks, A.; Pokrotnieks, J.; Sosare, L.; Reinholds, E.; Brezinskis, G.; Aboltins, A.

    2002-01-01

    The results of upper endoscopy in respect to the symptoms potentially indicative for duodenogastric reflux (DGR) have been compared to the results obtained by a scintigraphic method, elaborated by the group of the authors. Altogether 89 patients (48 women, 41 men) have been studied. For the analysis of signs indicative for functional disturbances of the upper digestive symptoms (status of the lower esophageal sphincter, gastric tone, presence of bile in the gastric content, status of the pyloric sphincter, influx of the duodenal content observed during the upper endoscopy, presence of the bile in the duodenum) the maximum accepted interval between the two investigations was 24 hours, while 1 month interval was accepted for the evaluations of structural changes (esophagitis, presence of hiatal hernis, gastritis and duodenitis, deformation of the pyloric sphincter and duodenal bulb. No statistically significant correlations has been found between any of the above mentioned parameters at upper endoscopy and the presence or absence of DGR as determined by the scintigraphic method. If a influx of the duodenal content into the stomach during the upper endoscopy, this could be considered as a specific indicator (specificity - 91,3%0, while the sensitivity (16,7%) is very low. There has been a trend to decreased DGR in patients with an atrophic gastritis, still this correlation was not statistically significant. The conclusion is made that the intubation of the stomach during the upper endoscopy could be causative for artificial DGR therefore leading to incorrect data interpretation and hyper diagnostics. (authors)

  15. Laser welding and ablation cutting process for hydraulic connections by remote handling in the ITER diagnostic port plug

    International Nuclear Information System (INIS)

    Pak, S.; Kim, Y.; Park, K.Y.; Lee, K.D.; Cheon, M.S.; Lee, H.G.

    2010-01-01

    To assess hydraulic connections between subcomponents of the International Thermonuclear Experimental Reactor (ITER) diagnostic port plug, we investigated the laser welding and ablation cutting process, which can be applied to remote handling maintenance. In this study, laser ablation cutting, which vaporizes a small amount of solid material directly into gas by focusing a laser beam of high-density energy, is adopted in order to overcome the limitation of the normal laser cutting technology that the head should be placed as close to the work piece as possible to blow out melt metal at a distance. Complete cutting of a work piece is obtained by repetitive multi-passes of the laser beam. The welding and cutting process were tested on the sample work pieces and finally on a prototype of a hydraulic connection module for remote handling. The results showed that this process can be a promising candidate for hydraulic connections by remote handling. Furthermore the design of the hydraulic connection module has been updated to resolve some technical difficulties that were found during the test.

  16. Laser welding and ablation cutting process for hydraulic connections by remote handling in the ITER diagnostic port plug

    Energy Technology Data Exchange (ETDEWEB)

    Pak, S. [National Fusion Research Institute, 52 Eoeun-dong, Yuseong-gu, Daejeon (Korea, Republic of)], E-mail: paksunil@nfri.re.kr; Kim, Y.; Park, K.Y.; Lee, K.D. [Institute for Advanced Engineering, 633-2, Goan-ri, Baegam-myeon, Cheoin-gu, Yongin-si, Gyeonggi-do (Korea, Republic of); Cheon, M.S.; Lee, H.G. [National Fusion Research Institute, 52 Eoeun-dong, Yuseong-gu, Daejeon (Korea, Republic of)

    2010-04-15

    To assess hydraulic connections between subcomponents of the International Thermonuclear Experimental Reactor (ITER) diagnostic port plug, we investigated the laser welding and ablation cutting process, which can be applied to remote handling maintenance. In this study, laser ablation cutting, which vaporizes a small amount of solid material directly into gas by focusing a laser beam of high-density energy, is adopted in order to overcome the limitation of the normal laser cutting technology that the head should be placed as close to the work piece as possible to blow out melt metal at a distance. Complete cutting of a work piece is obtained by repetitive multi-passes of the laser beam. The welding and cutting process were tested on the sample work pieces and finally on a prototype of a hydraulic connection module for remote handling. The results showed that this process can be a promising candidate for hydraulic connections by remote handling. Furthermore the design of the hydraulic connection module has been updated to resolve some technical difficulties that were found during the test.

  17. PERFORATION AS A COMPLICATION OF THE DIAGNOSTIC UPPER AND LOWER ENDOSCOPY OF THE GASTROINTESTINAL TRACT

    Directory of Open Access Journals (Sweden)

    Ivailo P. Vazharov

    2012-08-01

    Full Text Available Purpose: The purpose of this examination is to evaluate the risk of perforation during endoscopy of upper and lower gastrointestinal tract.Patients and methods used: 1210 diagnostic gastroduodenoscopies and 412 colonoscopies of hospitalized patients were performed by two experienced endoscopists for the period March 2007 – March 2012 at MHAT Varna, MMA. The endoscopies were performed without premedication and sedation. The patients were examined for complications of the procedure during and after the endoscopy. One of the most serious complications is the perforation of the oesophagus, stomach or the large intestine.Results: We had no perforations caused by the examination during the 1210 upper endoscopies performed. We had 2 perforations (0,48% from the 412 colonoscopies performed, which were treated successfully surgically.Conclusions: The perforation is a rare but serious complication of the endoscopy of gastrointestinal tract, which can be healed completely.

  18. The Use of a Magnetic Port Finder in the Retrieval of Air Rifle BBs to the Upper Extremity.

    Science.gov (United States)

    Kiwanuka, Elizabeth; Hsieh, Sun; Roussel, Lauren Ouellet; Jehle, Charles Christopher; Mehrzad, Raman; Schmidt, Scott

    2018-04-03

    Air-powered rifles shoot ball bearings with enough kinetic energy to penetrate skin and fracture underlying bones. In addition, there are reports of these ball bearings embolizing within the vascular network, causing serious injuries such as ischemic stroke with resultant blindness. The severity of these complications warrants occasional removal of these foreign bodies; however, they can be difficult to localize. In this case report, we describe the use of a magnetic port finder, a sterilizable tool used in breast reconstruction, to localize the foreign body in situ. We believe that this tool is effective at locating ferrous foreign bodies precisely, allowing for surgical retrieval while minimizing damage to surrounding tissue. Copyright © 2018 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  19. Hospital discharge diagnostic and procedure codes for upper gastro-intestinal cancer: how accurate are they?

    Directory of Open Access Journals (Sweden)

    Stavrou Efty

    2012-09-01

    Full Text Available Abstract Background Population-level health administrative datasets such as hospital discharge data are used increasingly to evaluate health services and outcomes of care. However information about the accuracy of Australian discharge data in identifying cancer, associated procedures and comorbidity is limited. The Admitted Patients Data Collection (APDC is a census of inpatient hospital discharges in the state of New South Wales (NSW. Our aim was to assess the accuracy of the APDC in identifying upper gastro-intestinal (upper GI cancer cases, procedures for associated curative resection and comorbidities at the time of admission compared to data abstracted from medical records (the ‘gold standard’. Methods We reviewed the medical records of 240 patients with an incident upper GI cancer diagnosis derived from a clinical database in one NSW area health service from July 2006 to June 2007. Extracted case record data was matched to APDC discharge data to determine sensitivity, positive predictive value (PPV and agreement between the two data sources (κ-coefficient. Results The accuracy of the APDC diagnostic codes in identifying site-specific incident cancer ranged from 80-95% sensitivity. This was comparable to the accuracy of APDC procedure codes in identifying curative resection for upper GI cancer. PPV ranged from 42-80% for cancer diagnosis and 56-93% for curative surgery. Agreement between the data sources was >0.72 for most cancer diagnoses and curative resections. However, APDC discharge data was less accurate in reporting common comorbidities - for each condition, sensitivity ranged from 9-70%, whilst agreement ranged from κ = 0.64 for diabetes down to κ  Conclusions Identifying incident cases of upper GI cancer and curative resection from hospital administrative data is satisfactory but under-ascertained. Linkage of multiple population-health datasets is advisable to maximise case ascertainment and minimise false

  20. Scintigraphy in diagnostics of algodystrophy in the upper extremity: a review

    International Nuclear Information System (INIS)

    Zyluk, A.

    1995-01-01

    Basing on the literature, the information concerning usefulness of the three phase scintigraphy in algodystrophy of the upper extremity, both in diagnostic and etiopathogenetic aspects were presented. Delayed image phase is the examination of the best value in the diagnostics of the condition (the highest sensitivity and specificity). Typical feature of algodystrophy on the bone scan is diffuse periarticular hyperfixation of the tracer, in many joints of the distal part of the extremity. Early phases of scintigraphy are valuable in staging of the disease (distinguishing between 1. and 2. stage), in choice of the method of the treatment (vasoconstrictive or vasodilatative) and in monitoring of the course of the treatment. Haemodynamic changes in dystrophic extremity, appearing in early phases, provide interesting information about the etiopathogenesis of algodystrophy. Prognostic implications of scintigraphy (the prediction of the possibility of algodystrophy developing and prediction of good result of the treatment) were mentioned. The method of quantitative analysis of the scans and the problems concerning the choice of proper region of interesting were discussed. (author). 20 refs, 1 tab

  1. Videofluoroscopy versus upper G.I. endoscopy: A comparative study as a diagnostic tool in patients presenting with dysphagia

    OpenAIRE

    Sharwak Ramlan; Sai Manohar; Gangadhara Somayaji

    2015-01-01

    Background and Objective: Dysphagia is a major symptom in many of the patients coming to the hospital. There can be various causes of dysphagia and its accurate diagnosis shows the way for the necessary treatment. Videofluoroscopy and upper gastrointestinal (GI) endoscopy are the two most commonly employed primary investigating modalities in assessing dysphagia. The objective of the study was to compare videofluoroscopy and upper GI endoscopy and establish a primary diagnostic tool for assess...

  2. Final design of ITER port plug test facility

    Energy Technology Data Exchange (ETDEWEB)

    Cerisier, Thierry, E-mail: thierry.cerisier@yahoo.fr [ITER Organization, Route de Vinon-sur-Verdon, CS 90046, St Paul-lez-Durance Cedex, 13067 (France); Levesy, Bruno [ITER Organization, Route de Vinon-sur-Verdon, CS 90046, St Paul-lez-Durance Cedex, 13067 (France); Romannikov, Alexander [Institution “Project Center ITER”, Kurchatov sq. 1, Building 3, Moscow 123182 (Russian Federation); Rumyantsev, Yuri [JSC “Cryogenmash”, Moscow reg., Balashikha 143907 (Russian Federation); Cordier, Jean-Jacques; Dammann, Alexis [ITER Organization, Route de Vinon-sur-Verdon, CS 90046, St Paul-lez-Durance Cedex, 13067 (France); Minakov, Victor; Rosales, Natalya; Mitrofanova, Elena [JSC “Cryogenmash”, Moscow reg., Balashikha 143907 (Russian Federation); Portone, Sergey; Mironova, Ekaterina [Institution “Project Center ITER”, Kurchatov sq. 1, Building 3, Moscow 123182 (Russian Federation)

    2016-11-01

    Highlights: • We introduce the port plug test facility (purpose and status of the design). • We present the PPTF sub-systems. • We present the environmental and functional tests. • We present the occupational and nuclear safety functions. • We conclude on the achievements and next steps. - Abstract: To achieve the overall ITER machine availability target, the availability of diagnostics and heating port plugs shall be as high as 99.5%. To fulfill this requirement, it is mandatory to test the port plugs at operating temperature before installation on the machine and after refurbishment. The ITER port plug test facility (PPTF) is composed of several test stands that can be used to test the port plugs whereas at the end of manufacturing (in a non-nuclear environment), or after refurbishment in the ITER hot cell facility. The PPTF provides the possibility to perform environmental (leak tightness, vacuum and thermo-hydraulic performances) and functional tests (radio frequency acceptance tests, behavior of the plugs’ steering mechanism and calibration of diagnostics) on upper and equatorial port plugs. The final design of the port plug test facility is described. The configuration of the standalone test stands and the integration in the hot cell facility are presented.

  3. Modelling the assessment of port wine stain parameters from skin surface temperature following a diagnostic laser pulse

    NARCIS (Netherlands)

    Gabay, S.; Lucassen, G. W.; Verkruysse, W.; van Gemert, M. J.

    1997-01-01

    Laser treatment of port wine stains (PWS) has become an established clinical modality over the past decade. However, in some cases full clearance of the PWS cannot be achieved. To improve the clinical results, it is necessary to match the laser treatment parameters to the PWS anatomy on an

  4. Ports Initiative

    Science.gov (United States)

    EPA's Ports Initiative works in collaboration with the port industry, communities, and government to improve environmental performance and increase economic prosperity. This effort helps people near ports breath cleaner air and live better lives.

  5. Endovascular diagnostics and treatment of stenosis, acute thrombosis and chronic occlusion of arteries and upper limbs

    International Nuclear Information System (INIS)

    Tonev, I.; Zechirov, B.; Stanoev, D.; Velikov, C.; Smilkova, D.

    2015-01-01

    Full text: Diseases of the upper limb arteries are significantly rarer than those of the lower limbs but they are not causes and due to the lack of diagnostic algorithms are often missed. the symptoms are not typical except for those in acute thrombosis. The complaints in acute thrombosis is strong, sudden pain in the limb or part of it, bruising or paleness of the ischemic area and a lack of pulsation. Diagnosis is fairly easy – clinical events, difference in blood pressure or a lack of blood pressure in the affected limb, a total lack of blood pressure or a difference in the pressure in the left and right arm. Then complaints in stenosis and chronic occlusions is significantly less pronounced and is expressed as weakness in the affected limb, heaviness, bluish or paleness. If the proximal segments are affected Still’s syndrome is often observed. The complaints is not decisive for diagnosis. A difference in blood pressure of more than 20 mm Hg and an echodoppler examination of the arteries are the main criteria for directing the patients for angiography. Contrast CT and MRT are not used often. treatment is vascular surgery and endovascular. In acute thrombosis priority takes vascular surgery through extraction of the thrombi with Fogerty catheters, and in chronical stenosis and occlusions – dilation and stenting. Clinical cases: Case 1 – Revascularization of artery brachialis, radialis and ulnaris after acute occlusion L.Y., 77 years old. Complains of sharp pain and bruising of right forearm since two hours before hospitalization. A lack of blood flow was identified using palpation and echodoppler. After a diagnostic angiography , thrombaspiration was undertaken, through a leading catheter, recovering blood flow in both arteries and stenting of the proximal segment of artery radialis. Case 2: Revascularization of Trunkus brachiocefalicus K.P., 65 years old. Suffering from bradypsychia for several months. Bradypsychia becomes worse after manual labor

  6. RADAR upper hybrid resonance scattering diagnostics of small-scale fluctuations and waves in tokamak plasmas

    International Nuclear Information System (INIS)

    Bulyiginskiy, D.G.; Gurchenko, A.D.; Gusakov, E.Z.; Korkin, V.V.; Larionov, M.M.; Novik, K.M.; Petrov, Yu.V.; Popov, A.Yu.; Saveliev, A.N.; Selenin, V.L.; Stepanov, A.Yu.

    2001-01-01

    The upper hybrid resonance (UHR) scattering technique possessing such merits as one-dimensional probing geometry, enhancement of cross section, and fine localization of scattering region is modified in the new diagnostics under development to achieve wave number resolution. The fluctuation wave number is estimated in the new technique from the scattering signal time delay measurements. The feasibility of the scheme is checked in the proof of principal experiment in a tokamak. The time delay of the UHR scattering signal exceeding 10 ns is observed. The small scale low frequency density fluctuations are investigated in the UHR RADAR backscattering experiment. The UHR cross-polarization scattering signal related to small scale magnetic fluctuations is observed. The lower hybrid (LH) wave propagation and both linear and nonlinear wave conversion are investigated. The small wavelength (λ≤0.02 cm) high number ion Bernstein harmonics, resulting from the linear wave conversion of the LH wave are observed in a tokamak plasma for the first time

  7. Validation and analysis of the coupled multiple response Colorado upper-division electrostatics diagnostic

    Directory of Open Access Journals (Sweden)

    Bethany R. Wilcox

    2015-11-01

    Full Text Available Standardized conceptual assessment represents a widely used tool for educational researchers interested in student learning within the standard undergraduate physics curriculum. For example, these assessments are often used to measure student learning across educational contexts and instructional strategies. However, to support the large-scale implementation often required for cross-institutional testing, it is necessary for these instruments to have question formats that facilitate easy grading. Previously, we created a multiple-response version of an existing, validated, upper-division electrostatics diagnostic with the goal of increasing the instrument’s potential for large-scale implementation. Here, we report on the validity and reliability of this new version as an independent instrument. These findings establish the validity of the multiple-response version as measured by multiple test statistics including item difficulty, item discrimination, and internal consistency. Moreover, we demonstrate that the majority of student responses to the new version are internally consistent even when they are incorrect and provide an example of how the new format can be used to gain insight into student difficulties with specific content in electrostatics.

  8. Diagnostic performance of the upper gastrointestinal series in the evaluation of children with clinically suspected malrotation

    International Nuclear Information System (INIS)

    Sizemore, Alecia W.; Rabbani, Kaneez Z.; Ladd, Alan; Applegate, Kimberly E.

    2008-01-01

    Malrotation is a congenital disorder of abnormal intestinal rotation and fixation that predisposes infants to potentially life-threatening midgut volvulus. Upper gastrointestinal tract (UGI) examination is sometimes equivocal and can lead to inaccurate diagnosis. To determine the diagnostic performance of UGI examinations in children who subsequently underwent a Ladd procedure for suspected malrotation or volvulus. We reviewed all children up to 21 years old who had undergone both a UGI examination and a Ladd procedure for possible malrotation across 9 years. Children were excluded if they had not undergone either a UGI examination or a Ladd procedure and if congenital abdominal wall defects were present. Of 229 patients identified, 166 (59% male, median age 67 days) were included. Excluded were 47 without a UGI series, 12 with omphalocele or gastroschisis, 1 without verifiable operative data, 1 who had not undergone a Ladd procedure, and 2 older than 21 years. Of the 166 patients, 40% were neonates and 73% were <12 months old, and 31% presented with bilious vomiting and 15% with abdominal distention. Of 163 patients with surgically verified malrotation, 156 had a positive UGI examination, a sensitivity of 96%. There were two patients with a false-positive UGI examination and seven with false-negative examination. Jejunal position was normal in six of the seven with a false-negative examination and abnormal in the two with a false-positive examination. Of 38 patients with surgically verified volvulus, 30 showed volvulus on the UGI series. Five required bowel resection and three died. Jejunal position can lead to inaccurate UGI series interpretation. Meticulous technique and periodic assessment of performance will help more accurately diagnose difficult or equivocal cases. (orig.)

  9. Diagnostic performance of the upper gastrointestinal series in the evaluation of children with clinically suspected malrotation

    Energy Technology Data Exchange (ETDEWEB)

    Sizemore, Alecia W [Indiana University School of Medicine, Department of Radiology, Indianapolis, IN (United States); University of Virginia School of Medicine, Department of Radiology, Charlottesville, VA (United States); Rabbani, Kaneez Z [Indiana University School of Medicine, Department of Medicine, Indianapolis, IN (United States); Ladd, Alan [Indiana University School of Medicine, Division of Pediatric Surgery, Riley Hospital, Indianapolis, IN (United States); Applegate, Kimberly E [Indiana University School of Medicine, Section of Pediatric Radiology, Department of Radiology, Indianapolis, IN (United States); Riley Hospital for Children, Department of Radiology, Indianapolis, IN (United States)

    2008-05-15

    Malrotation is a congenital disorder of abnormal intestinal rotation and fixation that predisposes infants to potentially life-threatening midgut volvulus. Upper gastrointestinal tract (UGI) examination is sometimes equivocal and can lead to inaccurate diagnosis. To determine the diagnostic performance of UGI examinations in children who subsequently underwent a Ladd procedure for suspected malrotation or volvulus. We reviewed all children up to 21 years old who had undergone both a UGI examination and a Ladd procedure for possible malrotation across 9 years. Children were excluded if they had not undergone either a UGI examination or a Ladd procedure and if congenital abdominal wall defects were present. Of 229 patients identified, 166 (59% male, median age 67 days) were included. Excluded were 47 without a UGI series, 12 with omphalocele or gastroschisis, 1 without verifiable operative data, 1 who had not undergone a Ladd procedure, and 2 older than 21 years. Of the 166 patients, 40% were neonates and 73% were <12 months old, and 31% presented with bilious vomiting and 15% with abdominal distention. Of 163 patients with surgically verified malrotation, 156 had a positive UGI examination, a sensitivity of 96%. There were two patients with a false-positive UGI examination and seven with false-negative examination. Jejunal position was normal in six of the seven with a false-negative examination and abnormal in the two with a false-positive examination. Of 38 patients with surgically verified volvulus, 30 showed volvulus on the UGI series. Five required bowel resection and three died. Jejunal position can lead to inaccurate UGI series interpretation. Meticulous technique and periodic assessment of performance will help more accurately diagnose difficult or equivocal cases. (orig.)

  10. [Analysis for serological diagnostic results of syphilis among entry personnel in Beijing port during 2012-2014].

    Science.gov (United States)

    Feng, M X; Sun, F J; Wang, F; Wang, K L; Liu, M

    2016-06-18

    To analyze the results of syphilis specific serological tests among entry personnel in Beijing port during year 2012-2014 in order to provide evidence for the prevention and control of syphilis. Demographics data and syphilis specific test results of entry personnel were obtained from the information system of Beijing International Travel Healthcare Center and input into Excel 2016. Database for entry personnel was built up accordingly and was analyzed by IBM SPSS22.0. The number of entry personnel in Beijing port during year 2012-2014 was 106 302 person-time. According to the evaluation criteria, 71 308 persons were recruited and analyzed, of whom 277 were tested serologically positive and the total prevalence was 0.39% (95% CI: 0.34%-0.43%). The prevalence was highest in the persons aged 40-49 years (0.81%) and was higher in males (0.50%) than in females (0.23%). The persons from Africa held higher prevalence (1.27%) than from other five regions. As multivariate logical regression analysis indicated that the risk of syphilis infection was 10.38 times more in the persons aged 40-49 years than in the persons 0.05). Twenty-seven seropositive cases were found within 6 246 entry persons who were tested repeatedly during the research period, 9 of which were seroconversion cases so that the cumulative conversion rate was 0.14% (9/6 228). The average conversion time was (6.3±3.0) months. There was no statistical significance between the cumulative seroconversion rates of the persons with different genders and nationalities (P of Fisher's exact test>0.05). Serological detection of syphilis for entry personnel in Beijing port and syphilis-related health education should be reinforced to reduce the risk of disease importing and spreading, protect susceptible subjects and promote health.

  11. ITER lower port systems integration

    Energy Technology Data Exchange (ETDEWEB)

    Levesy, B., E-mail: bruno.levesy@iter.org [ITER Organization, CS 90 046, 13067 St Paul Lez Durance Cedex (France); Baker, D.; Boussier, B.; Bryan, S.; Cordier, J.J.; Dremel, M.; Dell' Orco, G.; Daly, E.; Doshi, B.; Jeannoutot, T.; Friconneau, J.P.; Gliss, C.; Le Barbier, R.; Lachevre, F.; Loughlin, M.; Martin, A.; Martins, J.P.; Maruyama, S.; Palmer, J.; Reichle, R. [ITER Organization, CS 90 046, 13067 St Paul Lez Durance Cedex (France)

    2011-10-15

    The lower port systems are installed inside the vacuum vessel lower ports and in the adjacent port cells. The vacuum vessel ports and penetrations are allocated as follow: -4 ports dedicated to remote handling of the divertor cassettes, contain diagnostics racks and divertor cooling pipes. -5 ports connecting the main vessel to the torus cryopumps, contain divertor cooling pipes, pellet and gas injection pipes and vertical stabilization coil feeders. -3 penetrations connecting torus cryopumps are connected to the vacuum vessel by branch pipes. -Specific penetrations for divertor cooling lines, in-vessel viewing and glow discharge systems. The general layout of the port systems has been revised recently to improve the cryopump (8 t weight, 1.8 m diameter and 2.5 m long) maintenance scheme with remote handling tools and integrate the in-vessel vertical stabilization coil feeders. The port allocation, the pumping ports design, and interfaces in-between ports and cryostat and in-between cryopumps and cryostat have been up-dated. The integration inside the 18 port cells (11 m x 4 m each) has been reviewed to avoid clashes in between systems and to fix the openings in the port cell concrete walls. The new layout integrates safety and neutron-shielding requirements as well as remote handling and maintenance compatibility for the different systems. The paper presents the up-dated integration of the lower port systems inside the ports and the port cells. Interfaces of the port systems with the vacuum vessel, the cryostat and the port cells are described.

  12. Principal Ports

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Principal Ports are defined by port limits or US Army Corps of Engineers (USACE) projects, these exclude non-USACE projects not authorized for publication. The...

  13. [A retrospective controlled clinical study of single-incision plus one port laparoscopic surgery for sigmoid colon and upper rectal cancer].

    Science.gov (United States)

    Li, G X; Li, J M; Wang, Y N; Deng, H J; Mou, T Y; Liu, H

    2017-07-01

    Objective: To evaluate the short-term and oncologic outcomes of single-incision plus one port laparoscopic surgery (SILS+ 1) for sigmoid colon and upper rectal cancer. Methods: The clinic data of 46 patients with sigmoid colon and upper rectal cancer underwent SILS+ 1 at Department of General Surgery, Nanfang Hospital, Southern Medical University from September 2013 to September 2014 were retrospectively reviewed (SILS+ 1 group). After generating 1∶1 ration propensity scores given the covariates of age, gender, body mass index, American Society of Anesthesiologists score, surgeons, tumor location, the distance of tumor from anal, tumor diameter, and pathologic TNM stage, 46 patients with sigmoid colon and upper rectal cancer underwent conventional laparoscopic surgery (CLS) in the same time were matched as CLS group. The baseline characteristics and short-term outcomes were compared using t test, χ(2) test or Wilcoxon signed ranks test. Kaplan-Meier survival curves and Log-rank tests demonstrated the distribution of disease free survival. Results: The two study groups were well balanced with respect to the baseline characteristics of the propensity score derivation model. As compared to the CLS group, patients in SILS+ 1 group had a smaller incision ((6.9±1.1) cm vs . (8.4±1.2) cm, t =6.502, P =0.000), less estimated blood loss (20(11) ml vs . 50(30) ml, Z =2.414, P =0.016), shorter intracorporeal operating time ((67.0±25.8) minutes vs . (75.5±27.7) minutes, t =2.062, P =0.042) and significantly faster recovery course including shorter time to first ambulation ((46.7±20.3) hours vs . (78.6±28.0) hours, t =6.255, P =0.000), shorter time to first oral diet ((64.7±28.8) hours vs . (77.1±30.0) hours, t =2.026, P =0.047), shorter time of postoperative hospital stay ((7.8±2.2) days vs . (6.5±2.2) days, t =2.680, P =0.009), and lower postoperative visual analogue scale scores ( F =4.721, P =0.032). No significant difference was observed in total operating

  14. Diagnostic dilemma in vascular mal-formation of the upper lip: a ...

    African Journals Online (AJOL)

    richard

    2014-09-08

    Sep 8, 2014 ... Radiography, Lagos University Teaching Hospital, Lagos. *Corresponding author: ... To present a case of vascular lesion on the upper lip and its management. Methods: We .... midline of the face without bone involvement.

  15. Attributes of diagnostic tests to increase uptake of dual testing for syphilis and HIV in Port-au-Prince, Haiti.

    Science.gov (United States)

    Bristow, Claire C; Lee, Sung-Jae; Severe, Linda; William Pape, Jean; Javanbakht, Marjan; Scott Comulada, Warren; Klausner, Jeffrey D

    2017-03-01

    Introduction Syphilis and HIV screening is highly recommended for pregnant women and those at risk for infection. We used conjoint analysis to identify factors associated with testing preferences for HIV and syphilis infection. Methods We recruited 298 men and women 18 years and over seeking testing or care at GHESKIO (Haitian Study Group for Kaposi's Sarcoma and Opportunistic Infections) clinics. We created eight hypothetical dual HIV-syphilis test profiles varying across six dichotomous attributes. Participants were asked to rate each profile using Likert preference scales. An impact score was generated for each attribute by taking the difference between the preference scores for the preferred and non-preferred level of each attribute. Two-sided one-sample t-test was used to generate p values. Results Of 298 study participants, 61 (20.5%) were male. Of 237 females, 49 (20.7%) were pregnant. Cost (free vs. US$4; p syphilis testing preferences for this study sample in Port-au-Prince prioritized cost, single fingerprick, laboratory-based testing and timeliness.

  16. Diagnostic Ureteroscopy Prior to Radical Nephroureterectomy for Upper Tract Urothelial Carcinoma Increased the Risk of Intravesical Recurrence.

    Science.gov (United States)

    Tan, Ping; Xie, Nan; Yang, Lu; Liu, Liangren; Tang, Zhuang; Wei, Qiang

    2018-01-01

    To assess the impact of diagnostic ureteroscopy (URS) prior to radical nephroureterectomy (RNU) on intravesical recurrence (IVR) in patients with upper tract urothelial carcinoma (UTUC). A systematic literature search of the Medline, Embase, PubMed, and Cochrane library was performed in August 2017. Cumulative analyses of available hazard ratios (HRs) and their 95% CI were conducted using Stata version 12.0. Eleven studies including 4,057 participants were included, with a total of 1,403 patients diagnosed with IVR during the follow-up period. The pooled HRs of eight studies suggested that diagnostic URS prior to RNU significantly increased the IVR risk after RNU (HR 1.53, 95% CI 1.31-1.77; p guides decisions in UTUC, more future studies should be performed to find a novel way to mitigate the potential risk of IVR after RNU, such as chemoprophylaxis after endoscopy. © 2017 S. Karger AG, Basel.

  17. Additional Value of Upper GI Tract Endoscopy in the Diagnostic Assessment of Childhood IBD

    NARCIS (Netherlands)

    Hummel, Thalia Z.; ten Kate, Fiebo J. W.; Reitsma, Johannes B.; Benninga, Marc A.; Kindermann, Angelika

    2012-01-01

    Objectives: For the choice of treatment in children with inflammatory bowel disease (IBD), it is important to make a distinction between Crohn disease (CD) and ulcerative colitis (UC). To look for pathognomonic features of CD, upper gastrointestinal tract (UGT) endoscopy has become part of the

  18. Colorado Upper-Division Electrostatics Diagnostic: A Conceptual Assessment for the Junior Level

    Science.gov (United States)

    Chasteen, Stephanie V.; Pepper, Rachel E.; Caballero, Marcos D.; Pollock, Steven J.; Perkins, Katherine K.

    2012-01-01

    As part of an effort to systematically improve our junior-level E&M I course, we have developed a tool to assess student conceptual learning of electrostatics at the upper division. Together with a group of physics faculty, we established a list of learning goals for the course that, with results from student observations and interviews,…

  19. A comparison of analogue and digital techniques in upper gastrointestinal examinations: absorbed dose and diagnostic quality of the images

    Energy Technology Data Exchange (ETDEWEB)

    Axelsson, B.; Hansson, I.B. [Department of Hospital Physics, Karolinska Hospital, Stockholm (Sweden); Boden, K.; Witt, H.H. [Department of Diagnostic Radiology, Karolinska Hospital, Stockholm (Sweden); Fransson, S.G. [Department of Thoracic Radiology, University Hospital, Linkoeping (Sweden); Persliden, J. [Department of Radiation Physics, University Hospital, Linkoeping (Sweden)

    2000-08-01

    This study was performed to investigate whether patient exposure and diagnostic quality of the image is significantly influenced by the introduction of digital image acquisition techniques. Evaluation was performed for three different techniques (analogue, analogue fluoro+digital radiography, digital) in examination of the upper gastrointestinal tract. The evaluation was done from data acquired in three different departments. Patient exposure was recorded as KERMA-area product (KAP) and the individual patient readings were normalised to a standard size patient. Image quality was assessed using visual grading with a reference image. The recorded KAP values were significantly higher (22.3 Gycm{sup 2}) for the fully digital technique compared to the others (analogue 6.8 Gycm{sup 2}, analogue+digital 3.6 Gycm{sup 2}). This was due mostly to an increased number of exposures. The diagnostic quality of the image was, however, also regarded to be slightly lower for the technique giving the lowest patient dose with the smallest number of exposures (analogue+digital). The digital examination technique, as used in this study, thus resulted in significantly higher patient dose without any significant gain in diagnostic quality of the image. (orig.)

  20. A comparison of analogue and digital techniques in upper gastrointestinal examinations: absorbed dose and diagnostic quality of the images

    International Nuclear Information System (INIS)

    Axelsson, B.; Hansson, I.B.; Boden, K.; Witt, H.H.; Fransson, S.G.; Persliden, J.

    2000-01-01

    This study was performed to investigate whether patient exposure and diagnostic quality of the image is significantly influenced by the introduction of digital image acquisition techniques. Evaluation was performed for three different techniques (analogue, analogue fluoro+digital radiography, digital) in examination of the upper gastrointestinal tract. The evaluation was done from data acquired in three different departments. Patient exposure was recorded as KERMA-area product (KAP) and the individual patient readings were normalised to a standard size patient. Image quality was assessed using visual grading with a reference image. The recorded KAP values were significantly higher (22.3 Gycm 2 ) for the fully digital technique compared to the others (analogue 6.8 Gycm 2 , analogue+digital 3.6 Gycm 2 ). This was due mostly to an increased number of exposures. The diagnostic quality of the image was, however, also regarded to be slightly lower for the technique giving the lowest patient dose with the smallest number of exposures (analogue+digital). The digital examination technique, as used in this study, thus resulted in significantly higher patient dose without any significant gain in diagnostic quality of the image. (orig.)

  1. Intake port

    Science.gov (United States)

    Mendler, Edward Charles

    2005-02-01

    The volumetric efficiency and power of internal combustion engines is improved with an intake port having an intake nozzle, a venturi, and a surge chamber. The venturi is located almost halfway upstream the intake port between the intake valves and the intake plenum enabling the venturi throat diameter to be exceptionally small for providing an exceptionally high ram velocity and an exceptionally long and in turn high efficiency diffuser flowing into the surge chamber. The intake port includes an exceptionally large surge chamber volume for blow down of the intake air into the working cylinder of the engine.

  2. Dual-focus Magnification, High-Definition Endoscopy Improves Pathology Detection in Direct-to-Test Diagnostic Upper Gastrointestinal Endoscopy.

    Science.gov (United States)

    Bond, Ashley; Burkitt, Michael D; Cox, Trevor; Smart, Howard L; Probert, Chris; Haslam, Neil; Sarkar, Sanchoy

    2017-03-01

    In the UK, the majority of diagnostic upper gastrointestinal (UGI) endoscopies are a result of direct-to-test referral from the primary care physician. The diagnostic yield of these tests is relatively low, and the burden high on endoscopy services. Dual-focus magnification, high-definition endoscopy is expected to improve detection and classification of UGI mucosal lesions and also help minimize biopsies by allowing better targeting. This is a retrospective study of patients attending for direct-to-test UGI endoscopy from January 2015 to June 2015. The primary outcome of interest was the identification of significant pathology. Detection of significant pathology was modelled using logistic regression. 500 procedures were included. The mean age of patients was 61.5 (±15.6) years; 60.8% of patients were female. Ninety-four gastroscopies were performed using dual-focus magnification high-definition endoscopy. Increasing age, male gender, type of endoscope, and type of operator were all identified as significant factors influencing the odds of detecting significant mucosal pathology. Use of dual-focus magnification, high-definition endoscopy was associated with an odds ratio of 1.87 (95%CI 1.11-3.12) favouring the detection of significant pathology. Subsequent analysis suggested that the increased detection of pathology during dual-focus magnification, high-definition endoscopy also influenced patient follow-up and led to a 3.0 fold (p=0.04) increase in the proportion of patients entered into an UGI endoscopic surveillance program. Dual-focus magnification, high-definition endoscopy improved the diagnostic yield for significant mucosal pathology in patients referred for direct-to-test endoscopy. If this finding is recapitulated elsewhere it will have substantial impact on the provision of UGI endoscopic services.

  3. ITER diagnostic system: Vacuum interface

    International Nuclear Information System (INIS)

    Patel, K.M.; Udintsev, V.S.; Hughes, S.; Walker, C.I.; Andrew, P.; Barnsley, R.; Bertalot, L.; Drevon, J.M.; Encheva, A.; Kashchuk, Y.; Maquet, Ph.; Pearce, R.; Taylor, N.; Vayakis, G.; Walsh, M.J.

    2013-01-01

    Diagnostics play an essential role for the successful operation of the ITER tokamak. They provide the means to observe control and to measure plasma during the operation of ITER tokamak. The components of the diagnostic system in the ITER tokamak will be installed in the vacuum vessel, in the cryostat, in the upper, equatorial and divertor ports, in the divertor cassettes and racks, as well as in various buildings. Diagnostic components that are placed in a high radiation environment are expected to operate for the life of ITER. There are approx. 45 diagnostic systems located on ITER. Some diagnostics incorporate direct or independently pumped extensions to maintain their necessary vacuum conditions. They require a base pressure less than 10 −7 Pa, irrespective of plasma operation, and a leak rate of less than 10 −10 Pa m 3 s −1 . In all the cases it is essential to maintain the ITER closed fuel cycle. These directly coupled diagnostic systems are an integral part of the ITER vacuum containment and are therefore subject to the same design requirements for tritium and active gas confinement, for all normal and accidental conditions. All the diagnostics, whether or not pumped, incorporate penetration of the vacuum boundary (i.e. window assembly, vacuum feedthrough etc.) and demountable joints. Monitored guard volumes are provided for all elements of the vacuum boundary that are judged to be vulnerable by virtue of their construction, material, load specification etc. Standard arrangements are made for their construction and for the monitoring, evacuating and leak testing of these volumes. Diagnostic systems are incorporated at more than 20 ports on ITER. This paper will describe typical and particular arrangements of pumped diagnostic and monitored guard volume. The status of the diagnostic vacuum systems, which are at the start of their detailed design, will be outlined and the specific features of the vacuum systems in ports and extensions will be described

  4. ITER diagnostic system: Vacuum interface

    Energy Technology Data Exchange (ETDEWEB)

    Patel, K.M., E-mail: Kaushal.Patel@iter.org [ITER Organization, Route de Vinon sur Verdon, 13115 St Paul-Lez-Durance (France); Udintsev, V.S.; Hughes, S.; Walker, C.I.; Andrew, P.; Barnsley, R.; Bertalot, L. [ITER Organization, Route de Vinon sur Verdon, 13115 St Paul-Lez-Durance (France); Drevon, J.M. [Bertin Technologies, BP 22, 13762 Aix-en Provence cedex 3 (France); Encheva, A. [ITER Organization, Route de Vinon sur Verdon, 13115 St Paul-Lez-Durance (France); Kashchuk, Y. [Institution “PROJECT CENTER ITER”, 1, Akademika Kurchatova pl., Moscow (Russian Federation); Maquet, Ph. [Bertin Technologies, BP 22, 13762 Aix-en Provence cedex 3 (France); Pearce, R.; Taylor, N.; Vayakis, G.; Walsh, M.J. [ITER Organization, Route de Vinon sur Verdon, 13115 St Paul-Lez-Durance (France)

    2013-10-15

    Diagnostics play an essential role for the successful operation of the ITER tokamak. They provide the means to observe control and to measure plasma during the operation of ITER tokamak. The components of the diagnostic system in the ITER tokamak will be installed in the vacuum vessel, in the cryostat, in the upper, equatorial and divertor ports, in the divertor cassettes and racks, as well as in various buildings. Diagnostic components that are placed in a high radiation environment are expected to operate for the life of ITER. There are approx. 45 diagnostic systems located on ITER. Some diagnostics incorporate direct or independently pumped extensions to maintain their necessary vacuum conditions. They require a base pressure less than 10{sup −7} Pa, irrespective of plasma operation, and a leak rate of less than 10{sup −10} Pa m{sup 3} s{sup −1}. In all the cases it is essential to maintain the ITER closed fuel cycle. These directly coupled diagnostic systems are an integral part of the ITER vacuum containment and are therefore subject to the same design requirements for tritium and active gas confinement, for all normal and accidental conditions. All the diagnostics, whether or not pumped, incorporate penetration of the vacuum boundary (i.e. window assembly, vacuum feedthrough etc.) and demountable joints. Monitored guard volumes are provided for all elements of the vacuum boundary that are judged to be vulnerable by virtue of their construction, material, load specification etc. Standard arrangements are made for their construction and for the monitoring, evacuating and leak testing of these volumes. Diagnostic systems are incorporated at more than 20 ports on ITER. This paper will describe typical and particular arrangements of pumped diagnostic and monitored guard volume. The status of the diagnostic vacuum systems, which are at the start of their detailed design, will be outlined and the specific features of the vacuum systems in ports and extensions

  5. Diagnostics

    DEFF Research Database (Denmark)

    Donné, A.J.H.; Costley, A.E.; Barnsley, R.

    2007-01-01

    of the measurements—time and spatial resolutions, etc—will in some cases be more stringent. Many of the measurements will be used in the real time control of the plasma driving a requirement for very high reliability in the systems (diagnostics) that provide the measurements. The implementation of diagnostic systems...... on ITER is a substantial challenge. Because of the harsh environment (high levels of neutron and gamma fluxes, neutron heating, particle bombardment) diagnostic system selection and design has to cope with a range of phenomena not previously encountered in diagnostic design. Extensive design and R......&D is needed to prepare the systems. In some cases the environmental difficulties are so severe that new diagnostic techniques are required. The starting point in the development of diagnostics for ITER is to define the measurement requirements and develop their justification. It is necessary to include all...

  6. Use of remifentanil to reduce propofol injection pain and the required propofol dose in upper digestive tract endoscopy diagnostic tests.

    Science.gov (United States)

    Uliana, Gustavo Nadal; Tambara, Elizabeth Milla; Baretta, Giorgio Alfredo Pedroso

    2015-01-01

    The introduction of propofol (2,6-diisopropylphenol) as a sedative agent has transformed the area of sedation for endoscopic procedures. However, a major drawback of sedation with the use of propofol is its high incidence of injection pain. The most widely used technique in reducing propofol injection pain is through the association of other drugs. The aim of this study was to evaluate the effect of remifentanil-propofol combination on the incidence of propofol injection pain and its influence on the total dose of propofol required for sedation in upper digestive tract endoscopy (UDE) diagnostic tests. One hundred and five patients undergoing upper digestive tract endoscopy were evaluated and randomly divided into 3 groups of 35 patients each. The Control Group received propofol alone; Study-group 1 received remifentanil at a fixed dose of 0.2mg/kg combined with propofol; Study-group 2 received remifentanil at a fixed dose of 0.3mg/kg combined with propofol. The incidence of propofol injection pain and the total dose of propofol required for the test were evaluated. The sample was very similar regarding age, weight, height, sex, and physical status. Statistical analysis was performed according to the nature of the evaluated data. Student's t-test was used to compare the mean of age, weight, height (cm), and dose (mg/kg) variables between groups. The χ(2) test was used to compare sex, physical status, and propofol injection pain between groups. The significance level was αpain and total dose of propofol (mg/kg) used. However, there were no statistical differences between the two study groups for these parameters. We conclude that the use of remifentanil at doses of 0.2mg/kg and 0.3mg/kg was effective for reducing both the propofol injection pain and the total dose of propofol used. Copyright © 2015 Sociedade Brasileira de Anestesiologia. Published by Elsevier Editora Ltda. All rights reserved.

  7. Vacuum vessel port structures for ITER-FEAT

    International Nuclear Information System (INIS)

    Utin, Yu.; Ioki, K.; Komarov, V.; Krylov, V.; Kuzmin, E.; Labusov, I.; Miki, N.; Onozuka, M.; Rozov, V.; Sannazzaro, G.; Tesini, A.; Yamada, M.; Barthel, Th.

    2001-01-01

    The equatorial and the upper port structures are the most loaded among those of the ITER-FEAT vacuum vessel (VV). For all of these ports, the VV closure plate and the in-port components are integrated into the port plug. The plugs/port structures are affected by plasma events and must withstand high mechanical loads. Based on typical port plugs, this paper presents the conceptual design of the port structures (with emphasis on the supporting system), and the results of analyses performed

  8. Vacuum vessel port structures for ITER-FEAT

    Energy Technology Data Exchange (ETDEWEB)

    Utin, Yu.; Ioki, K.; Komarov, V.; Krylov, V.; Kuzmin, E.; Labusov, I.; Miki, N.; Onozuka, M.; Rozov, V.; Sannazzaro, G.; Tesini, A.; Yamada, M.; Barthel, Th

    2001-11-01

    The equatorial and the upper port structures are the most loaded among those of the ITER-FEAT vacuum vessel (VV). For all of these ports, the VV closure plate and the in-port components are integrated into the port plug. The plugs/port structures are affected by plasma events and must withstand high mechanical loads. Based on typical port plugs, this paper presents the conceptual design of the port structures (with emphasis on the supporting system), and the results of analyses performed.

  9. Comparison of the diagnostic performance of microscopic examination with nested polymerase chain reaction for optimum malaria diagnosis in Upper Myanmar.

    Science.gov (United States)

    Kang, Jung-Mi; Cho, Pyo-Yun; Moe, Mya; Lee, Jinyoung; Jun, Hojong; Lee, Hyeong-Woo; Ahn, Seong Kyu; Kim, Tae Im; Pak, Jhang Ho; Myint, Moe Kyaw; Lin, Khin; Kim, Tong-Soo; Na, Byoung-Kuk

    2017-03-16

    Accurate diagnosis of Plasmodium infection is crucial for prompt malaria treatment and surveillance. Microscopic examination has been widely applied as the gold standard for malaria diagnosis in most part of malaria endemic areas, but its diagnostic value has been questioned, particularly in submicroscopic malaria. In this study, the diagnostic performance of microscopic examination and nested polymerase chain reaction (PCR) was evaluated to establish optimal malaria diagnosis method in Myanmar. A total of 1125 blood samples collected from residents in the villages and towns located in Naung Cho, Pyin Oo Lwin, Tha Beik Kyin townships and Mandalay of Upper Myanmar were screened by microscopic examination and species-specific nested PCR method. Among the 1125 blood samples, 261 samples were confirmed to be infected with malaria by microscopic examination. Evaluation of the 1125 samples by species-specific nested PCR analysis revealed that the agreement between microscopic examination and nested PCR was 87.3% (261/299). Nested PCR successfully detected 38 Plasmodium falciparum or Plasmodium vivax infections, which were missed in microscopic examination. Microscopic examinations also either misdiagnosed the infected Plasmodium species, or did not detect mixed infections with different Plasmodium species in 31 cases. The nested PCR method is more reliable than conventional microscopic examination for the diagnosis of malaria infections, and this is particularly true in cases of mixed infections and submicroscopic infections. Given the observed higher sensitivity and specificity of nested PCR, the molecular method holds enormous promise in malaria diagnosis and species differentiation, and can be applied as an effective monitoring tool for malaria surveillance, control and elimination in Myanmar.

  10. Ports Primer: 3.2 Port Governance

    Science.gov (United States)

    State and local governments are important players in port governance and in oversight of transportation projects that may affect ports. Private corporations may also play a role if they lease or own a terminal at a port.

  11. Difficult identification of Haemophilus influenzae, a typical cause of upper respiratory tract infections, in the microbiological diagnostic routine.

    Science.gov (United States)

    Hinz, Rebecca; Zautner, Andreas Erich; Hagen, Ralf Matthias; Frickmann, Hagen

    2015-03-01

    Haemophilus influenzae is a key pathogen of upper respiratory tract infections. Its reliable discrimination from nonpathogenic Haemophilus spp. is necessary because merely colonizing bacteria are frequent at primarily unsterile sites. Due to close phylogenetic relationship, it is not easy to discriminate H. influenzae from the colonizer Haemophilus haemolyticus. The frequency of H. haemolyticus isolations depends on factors like sampling site, patient condition, and geographic region. Biochemical discrimination has been shown to be nonreliable. Multiplex PCR including marker genes like sodC, fucK, and hpd or sequencing of the 16S rRNA gene, the P6 gene, or multilocus-sequence-typing is more promising. For the diagnostic routine, such techniques are too expensive and laborious. If available, matrix-assisted laser-desorption-ionization time-of-flight mass spectrometry is a routine-compatible option and should be used in the first line. However, the used database should contain well-defined reference spectra, and the spectral difference between H. influenzae and H. haemolyticus is small. Fluorescence in-situ hybridization is an option for less well-equipped laboratories, but the available protocol will not lead to conclusive results in all instances. It can be used as a second line approach. Occasional ambiguous results have to be resolved by alternative molecular methods like 16S rRNA gene sequencing.

  12. HomePort

    DEFF Research Database (Denmark)

    Madsen, Per Printz

    2009-01-01

    In the last couple of year's computer based home control systems are getting more and more common in modern homes. For instance these systems take care of light control, heat control and security systems.  The latest trend is to use wireless communication like Z-Wave and ZigBee to interconnect...... different components in these systems. One of the characteristics is that each system, like for instance heat and light, has their own specific way of using the communication system.   This paper describes a way to connect different home control systems through an intelligent gateway, called a Home......Port. The HomePort consists of a number of Subsystem communication drivers, a virtual communication layer, an interpreter and a PC- based compiler for a high level control language, called GIL (Gateway intelligence language). The focus in this paper will be on the upper two layers in the Home...

  13. Impact of the layout of the ITER Radial Neutron Camera in-port system on the measurement of the neutron emissivity profile

    International Nuclear Information System (INIS)

    Marocco, D.; Moro, F.; Esposito, B.; Brolatti, G.; Villari, R.; Salasca, S.; Cantone, B.

    2013-01-01

    Highlights: ► MCNP ITER model ‘Alite-4′ has been updated with the new Port Plug structure (three vertical drawers). ► Two different layouts for the Radial Neutron Camera (RNC) in-vessel system have been considered. ► The impact of both layouts on the RNC diagnostic performance has been assessed. ► The analysis provides useful information for a proper integration of the RNC in the EPP1. -- Abstract: The Radial Neutron Camera (RNC), located in the ITER Equatorial Port Plug 1 (EPP1), is designed to provide the neutron emissivity profile through the measurement of the neutron flux along several collimated channels. The present design of the RNC is based on collimating structures: an ex-port system viewing the plasma core and an in-port system composed by two detector cassettes viewing the upper and lower plasma edges. A design of the EPP1 in which the diagnostics are installed in three completely independent vertical drawers is under study. In this frame, space optimization and integration issues suggest two possible solutions for the layout of the in-port RNC cassettes: the first one in which both cassettes are located in a side drawer; the second one in which the two cassettes lie in the central drawer, on opposite sides of the ex-port RNC cut-out. This paper describes the work performed to assess the impact of the two different in-port system layouts on the capability of the RNC to measure the neutron emissivity profile by means of MCNP and diagnostic performance calculations. The results of the analysis provide guidelines for the integration of the RNC into the EPP1 showing that the proximity of the in-port cassettes to the ex-port cut-out strongly increases the amount of uncollimated and scattered neutrons at the detector positions, thus reducing the diagnostic measurement capability

  14. Thermo-hydraulic analysis of the generic equatorial port plug design

    International Nuclear Information System (INIS)

    Rodríguez, E.; Guirao, J.; Ordieres, J.; Cortizo, J.L.; Iglesias, S.

    2012-01-01

    Highlights: ► Thermo-hydraulic transient performance evaluation and optimization of the GEPP structure cooling/heating system under neutronic heating and baking conditions. ► The optimization of the GEPP box structure's cooling system includes positioning and minimization of number and size of gun drilled channels, complying with the flow and functional requirements during operating and baking conditions. - Abstract: The port-based ITER diagnostic systems are housed primarily in two locations, the equatorial and upper port plugs. The port plug structure provides confinement function, maintains ultra-high vacuum quality and the first confinement barrier for radioactive materials at the ports. The port plug structure design, from the ITER International Organisation (IO), is cooled and heated by pressurized water which flows through a series of gun-drilled water channels and water pipes. The cooling function is required to remove nuclear heating due to radiation during operation of ITER, while the heating function is intended to heat up uniformly the machine during baking condition. The work presented provides coupled thermo-hydraulic analysis and optimization of a Generic Equatorial Port Plug (GEPP) structure cooling and heating system. The optimization performed includes positioning, minimization of number and size of gun drilled channels, complying with the flow and functional requirements during operating and baking conditions.

  15. ITER diagnostics: Maintenance and commissioning in the hot cell test bed

    International Nuclear Information System (INIS)

    Walker, C.I.; Barnsley, R.; Costley, A.E.; Gottfried, R.; Haist, B.; Itami, K.; Kondoh, T.; Loesser, G.D.; Palmer, J.; Sugie, T.; Tesini, A.; Vayakis, G.

    2005-01-01

    In-vessel diagnostic equipment in ITER integrated in six equatorial and 12 upper ports, 16 divertor cassettes and five lower ports is designed to be removed in modules and then repaired, tested and commissioned in the same location at the ITER hot cell. The repair requirements and tests on these components are described along with design features that facilitate repair. The testing establishes the repair strategy, qualifies the refurbishment work and finally checks the mechanical and diagnostic function before the return of the modules. At the hot cell, a dummy port is provided for tests of mechanical and vacuum integrity as well as commissioning of the diagnostic equipment. The scope of the hot cell maintenance and commissioning activities is summarised and an overview of the integration of the diagnostic equipment is given

  16. Design progress of the VV sectors and ports towards the ITER construction

    International Nuclear Information System (INIS)

    Utin, Yu.; Ioki, K.; Bachmann, C.

    2007-01-01

    The ITER vacuum vessel (VV) is an all-welded torus-shaped double-wall structure with stiffening ribs between the shells. The VV main function is to provide the high-vacuum and primary confinement boundary. The vessel also supports in-vessel components such as the blanket modules and the divertor cassettes. Along with these components, the VV provides radiation shielding - the neutron heat is removed by water circulating between the shells. To satisfy the manufacture and assembly needs, the VV consists of nine sectors. To provide access inside the vessel for auxiliary plasma heating, diagnostics, vacuum pumping and other needs, the VV is equipped with upper, equatorial and lower ports. The upper and regular equatorial ports are occupied with the port plugs. In addition, there are three ports at the equatorial level dedicated for neutral beam (NB) injection. As the ITER construction phase approaches, the VV design has been improved and developed in more detail with the focus on improved manufacture and reduced cost. Based on achievements of manufacturing studies being performed in cooperation with industry, design improvement of the typical VV sector (1) has been nearly finalized. Design improvement of other sectors is in progress - in particular, of the VV sectors 2 and 3 which interface with the NB ports. For all sectors, the concept for the in-wall shielding has been improved and developed in more detail. The design progress of VV sectors 2-3 has been accompanied by progress in the NB port design (including the beam-facing components to handle the heat flux input of the neutral beams). Design of other port structures has also progressed. Thus, supporting and sealing components between the port plugs and the ports have been further developed with the focus on improved structural performance and maintenance. At the lower level, there are full-size ports, and the pipe feedthroughs and local small penetrations. Design of all port structures at this level has

  17. Three ports versus four ports laparoscopic cholecystectomy

    International Nuclear Information System (INIS)

    Shah, S.F.; Waqar, S.; Chaudry, M.A.; Hameed, S.

    2017-01-01

    To compare three ports laparoscopic cholecystectomy and four ports laparoscopic cholecystectomy in terms of complications, time taken to complete the procedure, hospital stay and cost effectiveness in local perspective. Methodology: This randomized control trial included 60 patients who underwent elective laparoscopic cholecystectomy at Department of Surgery, Pakistan Institute of Medical Sciences, Islamabad, Pakistan from January 2013 to June 2013. These patients were randomized on computer generated table of random numbers into group A and Group B. In Group A patients four ports were passed to perform laparoscopic cholecystectomy and in Group B patients three ports were passed to perform the procedure. Results: The mean age in both groups was 44 years (range 18-72). Three ports laparoscopic cholecystectomy (43 min) took less time to complete than four ports laparoscopic cholecystectomy (51 min). Patients in three ports laparoscopic cholecystectomy experienced less pain as compared to four ports group. The total additional analgesia requirement in 24 hours calculated in milligrams was less in three port laparoscopic cholecystectomy group as compared four port laparoscopic cholecystectomy group. The mean hospital stay in three port laparoscopic cholecystectomy group is 25 hours while the mean hospital stay in the four port laparoscopic cholecystectomy group is 28 hours. Conclusion: Three ports laparoscopic cholecystectomy is safe and effective procedure and it did not compromise the patient safety. (author)

  18. Principal Ports and Facilities

    Data.gov (United States)

    California Natural Resource Agency — The Principal Port file contains USACE port codes, geographic locations (longitude, latitude), names, and commodity tonnage summaries (total tons, domestic, foreign,...

  19. Principal Ports and Facilities

    Data.gov (United States)

    California Department of Resources — The Principal Port file contains USACE port codes, geographic locations (longitude, latitude), names, and commodity tonnage summaries (total tons, domestic, foreign,...

  20. Diagnostic accuracy of ultrasound in upper and lower extremity long bone fractures of emergency department trauma patients.

    Science.gov (United States)

    Frouzan, Arash; Masoumi, Kambiz; Delirroyfard, Ali; Mazdaie, Behnaz; Bagherzadegan, Elnaz

    2017-08-01

    Long bone fractures are common injuries caused by trauma. Some studies have demonstrated that ultrasound has a high sensitivity and specificity in the diagnosis of upper and lower extremity long bone fractures. The aim of this study was to determine the accuracy of ultrasound compared with plain radiography in diagnosis of upper and lower extremity long bone fractures in traumatic patients. This cross-sectional study assessed 100 patients admitted to the emergency department of Imam Khomeini Hospital, Ahvaz, Iran with trauma to the upper and lower extremities, from September 2014 through October 2015. In all patients, first ultrasound and then standard plain radiography for the upper and lower limb was performed. Data were analyzed by SPSS version 21 to determine the specificity and sensitivity. The mean age of patients with upper and lower limb trauma were 31.43±12.32 years and 29.63±5.89 years, respectively. Radius fracture was the most frequent compared to other fractures (27%). Sensitivity, specificity, positive predicted value, and negative predicted value of ultrasound compared with plain radiography in the diagnosis of upper extremity long bones were 95.3%, 87.7%, 87.2% and 96.2%, respectively, and the highest accuracy was observed in left arm fractures (100%). Tibia and fibula fractures were the most frequent types compared to other fractures (89.2%). Sensitivity, specificity, PPV and NPV of ultrasound compared with plain radiography in the diagnosis of upper extremity long bone fractures were 98.6%, 83%, 65.4% and 87.1%, respectively, and the highest accuracy was observed in men, lower ages and femoral fractures. The results of this study showed that ultrasound compared with plain radiography has a high accuracy in the diagnosis of upper and lower extremity long bone fractures.

  1. Shutdown dose rates at ITER equatorial ports considering radiation cross-talk from torus cryopump lower port

    Energy Technology Data Exchange (ETDEWEB)

    Juárez, Rafael, E-mail: rjuarez@ind.uned.es [Departamento de Ingeniería Energética, ETSII-UNED, Calle Juan del Rosal 12, Madrid 28040 (Spain); Pampin, Raul [F4E, Torres Diagonal Litoral B3, Josep Pla 2, Barcelona 08019 (Spain); Levesy, Bruno [ITER Organization, 13115 Route de Vinon sur Verdon, St Paul Lez Durance (France); Moro, Fabio [ENEA, Via Enrico Fermi 45, Frascati, Rome (Italy); Suarez, Alejandro [ITER Organization, 13115 Route de Vinon sur Verdon, St Paul Lez Durance (France); Sanz, Javier [Departamento de Ingeniería Energética, ETSII-UNED, Calle Juan del Rosal 12, Madrid 28040 (Spain)

    2015-11-15

    Shutdown dose rates for planned maintenance purposes is an active research field in ITER. In this work the radiation (neutron and gamma) cross-talk between ports in the most conservative case foreseen in ITER is investigated: the presence of a torus cryopump lower port, mostly empty for pumping efficiency reasons. There will be six of those ports: #4, #6, #10, #12, #16 and #18. The equatorial ports placed above them will receive a significant amount of additional radiation affecting the shutdown dose rates during in situ maintenance activities inside the cryostat, and particularly in the port interspace area. In this study a general situation to all the equatorial ports placed above torus cryopump lower ports is considered: a generic diagnostics equatorial port placed above the torus cryopump lower port (LP#4). In terms of shutdown dose rates at equatorial port interspace after 10{sup 6} s of cooling time, 405 μSv/h has been obtained, of which 160 μSv/h (40%) are exclusively due to radiation cross-talk from a torus cryopump lower port. Equatorial port activation due to only “local neutrons” contributes 166 μSv/h at port interspace, showing that radiation cross-talk from such a lower port is a phenomenon comparable in magnitude to the neutron leakage though the equatorial port plug.

  2. Studies on improvement of diagnostic ability of computed tomography (CT) in the parenchymatous organs in the upper abdomen, 1. Study on the upper abdominal compression method

    Energy Technology Data Exchange (ETDEWEB)

    Kawata, Ryo [Gifu Univ. (Japan). Faculty of Medicine

    1982-07-01

    1) The upper abdominal compression method was easily applicable for CT examination in practically all the patients. It gave no harm and considerably improved CT diagnosis. 2) The materials used for compression were foamed polystyrene, the Mix-Dp and a water bag. When CT examination was performed to diagnose such lesions as a circumscribed tumor, compression with the Mix-Dp was most useful, and when it was performed for screening examination of upper abdominal diseases, compression with a water bag was most effective. 3) Improvement in contour-depicting ability of CT by the compression method was most marked at the body of the pancreas, followed by the head of the pancreas and the posterior surface of the left lobe of the liver. Slight improvement was seen also at the tail of the pancreas and the left adrenal gland. 4) Improvement in organ-depicting ability of CT by the compression method was estimated by a 4-category classification method. It was found that the improvement was most marked at the body and the head of the pancreas. Considerable improvement was observed also at the left lobe of the liver and the both adrenal glands. Little improvement was obtained at the spleen. When contrast enhancement was combined with the compression method, improvement at such organs which were liable to be enhanced, as the liver and the adrenal glands, was promoted, while the organ-depicting ability was decreased at the pancreas. 5) By comparing the CT image under compression with that without compression, continuous infiltrations of gastric cancer into the body and the tail of the pancreas in 2 cases and a retroperitoneal infiltration of pancreatic tumor in 1 case were diagnosed preoperatively.

  3. Port of Rotterdam

    NARCIS (Netherlands)

    Veenstra, A.W.

    2014-01-01

    The port of Rotterdam is one of the largest ports in the World and has great significance for the Dutch and European economy. Newly appointed TU/e professor Albert Veenstra explains if and how the Port of Rotterdam is affected by the economic crisis. With other European ports closing in, what can

  4. Strategic port development

    DEFF Research Database (Denmark)

    Olesen, Peter Bjerg; Dukovska-Popovska, Iskra; Hvolby, Hans-Henrik

    2014-01-01

    While large global ports are recognised as playing a central role in many supply chains as logistic gateways, smaller regional ports have been more stagnant and have not reached the same level of development as the larger ports. The research literature in relation to port development is also...

  5. Port-Wine Stains

    Science.gov (United States)

    ... Safe Videos for Educators Search English Español Port-Wine Stains KidsHealth / For Parents / Port-Wine Stains What's ... Manchas de vino de oporto What Are Port-Wine Stains? A port-wine stain is a type ...

  6. Flat-port connectors

    KAUST Repository

    Alrashed, Mohammed

    2017-05-26

    Disclosed are various embodiments for connectors used with electronic devices, such as input and/or output ports to connect peripheral equipment or accessories. More specifically, various flat-port are provided that can be used in place of standard connectors including, but not limited to, audio jacks and Universal Serial Bus (USB) ports. The flat-port connectors are an alternate connection design to replace the traditional receptacle port (female-port), making the device more sealed creation more dust and water resistant. It is unique in the way of using the outer surfaces of the device for the electrical connection between the ports. Flat-port design can allow the manufacture of extremely thin devices by eliminating the side ports slots that take a lot of space and contribute to the increase thickness of the device. The flat-port receptacle improves the overall appearance of the device and makes it more resistant to dust and water.

  7. Management of Port Operations

    OpenAIRE

    Gheorghe BASANU; Georgiana NUKINA

    2011-01-01

    The Management of port operation requires the proper and efficient use of port facility, equipment for cargo handling, berth facilities, waterways and roads. It also entails the use of effective communications system, storage facilities, and dockworkers. The whole activities mentioned above form the bulk of port operations. The aspiration of port operator is to get cargo through the gateway of ports as fast as possible on to other modes of transport (rail or road) with a minimal cost to them ...

  8. The Role of Endoscopic Ultrasound in the Diagnostic Assessment of Subepithelial Lesions of the Upper Gastrointestinal Tract

    Directory of Open Access Journals (Sweden)

    Francisca Dias de Castro

    2016-11-01

    Conclusion: EUS is the method of choice in the study of subepithelial lesions of the upper gastrointestinal tract, in most cases defining a diagnosis. The need for a definitive diagnosis or therapeutic approaches can be based on ultrasound risk features, presented, in the majority, at presentation. This study shows that EUS is capable of safely and accurately define those subepithelial lesions that can be managed only with surveillance ultrasound while waiting for better results with fine needle aspiration.

  9. Severe form of streptococcal necrotizing fasciitis of the upper limb - diagnostic and therapeutic challenge: A case report

    Directory of Open Access Journals (Sweden)

    Mikić Dragan

    2015-01-01

    Full Text Available Introduction. Since delay in recognition and effective treatment of necrotizing fasciitis (NF caused by invasive group A streptococcus increases the mortality and disability, the early diagnosis and management of this disease are essential for a better outcome. We presented a patient with a severe form of streptococcal NF of the left upper limb in whom amputation was performed as a life saving procedure. Case report. A 65-year-old man, previously healthy, suffered an injury to his left hand by sting on a fish bone. Two days after that the patient got fever, redness, swelling and pain in his left hand. Clinical examination of the patient after admission indicated NF that spread quickly to the entire left upper limb, left armpit, and the left side of the chest and abdomen. Despite the use of aggressive antibiotic and surgical therapy severe destruction of the skin and subcutaneous tissues developed with the development of gangrene of the left upper limb. In this situation, the team of specialists decided that the patient must be operated on submited to amputation of the left arm, at the shoulder. After amputation and aggressive debridement of soft tissue on the left side of the trunk, the patient completely recovered. β-hemolytic streptococcus group A was isolated from the skin and tissue obtained during the surgery. Conclusion. In the most severe forms of streptococcal NF of the extremities, adequate multidisciplinary treatment, including limb amputation, can save the life of a patient.

  10. Diagnostic accuracy of age and alarm symptoms for upper GI malignancy in patients with dyspepsia in a GI clinic: a 7-year cross-sectional study.

    Directory of Open Access Journals (Sweden)

    Hooman Khademi

    Full Text Available OBJECTIVES: We investigated whether using demographic characteristics and alarm symptoms can accurately predict cancer in patients with dyspepsia in Iran, where upper GI cancers and H. pylori infection are common. METHODS: All consecutive patients referred to a tertiary gastroenterology clinic in Tehran, Iran, from 2002 to 2009 were invited to participate in this study. Each patient completed a standard questionnaire and underwent upper gastrointestinal endoscopy. Alarm symptoms included in the questionnaire were weight loss, dysphagia, GI bleeding, and persistent vomiting. We used logistic regression models to estimate the diagnostic value of each variable in combination with other ones, and to develop a risk-prediction model. RESULTS: A total of 2,847 patients with dyspepsia participated in this study, of whom 87 (3.1% had upper GI malignancy. Patients reporting at least one of the alarm symptoms constituted 66.7% of cancer patients compared to 38.9% in patients without cancer (p<0.001. Esophageal or gastric cancers in patients with dyspepsia was associated with older age, being male, and symptoms of weight loss and vomiting. Each single predictor had low sensitivity and specificity. Using a combination of age, alarm symptoms, and smoking, we built a risk-prediction model that distinguished between high-risk and low-risk individuals with an area under the ROC curve of 0.85 and acceptable calibration. CONCLUSIONS: None of the predictors demonstrated high diagnostic accuracy. While our risk-prediction model had reasonable accuracy, some cancer cases would have remained undiagnosed. Therefore, where available, low cost endoscopy may be preferable for dyspeptic older patient or those with history of weight loss.

  11. Comprehensive MR Urography Protocol: Equally Good Diagnostic Performance and Enhanced Visibility of the Upper Urinary Tract Compared to Triple-Phase CT Urography.

    Directory of Open Access Journals (Sweden)

    Mazen Sudah

    Full Text Available To prospectively compare the diagnostic performance and the visualization of the upper urinary tract (UUT using a comprehensive 3.0T- magnetic resonance urography (MRU protocol versus triple-phase computed tomography urography (CTU.During the study period (January-2014 through December-2015, all consecutive patients in our tertiary university hospital scheduled by a urologist for CTU to exclude UUT malignancy were invited to participate. Diagnostic performance and visualization scores of 3.0T-MRU were compared to CTU using Wilcoxon matched-pairs test.Twenty patients (39 UUT excreting units were evaluated. 3.0T-MRU and CTU achieved equal diagnostic performances. The benign etiology of seven UUT obstructions was clarified equally with both methods. Another two urinary tract malignant tumors and one benign extraurinary tumor were detected and confirmed. Diagnostic visualization was slightly better in the intrarenal cavity areas with CTU but worsened towards distal ureter. MRU showed consistently slightly better visualization of the ureter. In the comparison, full 100% visualizations were detected in all areas in 93.6% (with 3.0T-MRU and 87.2% (with CTU and >75% visualization in 100% (3.0T-MRU and 93.6% (CTU. Mean CTU effective radiation dose was 9.2 mSv.Comprehensive 3.0T-MRU is an accurate imaging modality achieving comparable performance with CTU; since it does not entail exposure to radiation, it has the potential to become the primary investigation technique in selected patients.ClinicalTrials.gov NCT02606513.

  12. Port Authority Best Practices

    Science.gov (United States)

    Best practices for port authorities include near-port community collaboration, anti-idling policies, expanding off-peak hours, development of EMS, developing an emissions inventory, education, electric power and substituting trucking for rail or barge.

  13. US Ports of Entry

    Data.gov (United States)

    Department of Homeland Security — HSIP Non-Crossing Ports-of-Entry A Port of Entry is any designated place at which a CBP officer is authorized to accept entries of merchandise to collect duties, and...

  14. Studies on improvement of diagnostic ability of computed tomography (CT) in the parenchymatous organs in the upper abdomen, 1

    International Nuclear Information System (INIS)

    Kawata, Ryo

    1982-01-01

    1) The upper abdominal compression method was easily applicable for CT examination in practically all the patients. It gave no harm and considerably improved CT diagnosis. 2) The materials used for compression were foamed polystyrene, the Mix-Dp and a water bag. When CT examination was performed to diagnose such lesions as a circumscribed tumor, compression with the Mix-Dp was most useful, and when it was performed for screening examination of upper abdominal diseases, compression with a water bag was most effective. 3) Improvement in contour-depicting ability of CT by the compression method was most marked at the body of the pancreas, followed by the head of the pancreas and the posterior surface of the left lobe of the liver. Slight improvement was seen also at the tail of the pancreas and the left adrenal gland. 4) Improvement in organ-depicting ability of CT by the compression method was estimated by a 4-category classification method. It was found that the improvement was most marked at the body and the head of the pancreas. Considerable improvement was observed also at the left lobe of the liver and the both adrenal glands. Little improvement was obtained at the spleen. When contrast enhancement was combined with the compression method, improvement at such organs which were liable to be enhanced, as the liver and the adrenal glands, was promoted, while the organ-depicting ability was decreased at the pancreas. 5) By comparing the CT image under compression with that without compression, continuous infiltrations of gastric cancer into the body and the tail of the pancreas in 2 cases and a retroperitoneal infiltration of pancreatic tumor in 1 case were diagnosed preoperatively. (J.P.N.)

  15. Flat-port connectors

    KAUST Repository

    Alrashed, Mohammed

    2017-01-01

    and water resistant. It is unique in the way of using the outer surfaces of the device for the electrical connection between the ports. Flat-port design can allow the manufacture of extremely thin devices by eliminating the side ports slots that take a lot

  16. Getting Port Governance Right

    DEFF Research Database (Denmark)

    de Langen, Peter; Saragiotis, Periklis

    2018-01-01

    This chapter discusses the relevance of ports for economic development and next identifies port governance as a critical determinant of a well-functioning port industry. While in the past decades privately owned terminal operating companies have emerged and contributed to more efficient supply ch...

  17. Shipping emissions in ports

    OpenAIRE

    Merk, Olaf

    2014-01-01

    Shipping emissions in ports are substantial, accounting for 18 million tonnes of CO2 emissions, 0.4 million tonnes of NOx, 0.2 million of SOx and 0.03 million tonnes of PM10 in 2011. Around 85% of emissions come from containerships and tankers. Containerships have short port stays, but high emissions during these stays. Most of CO2 emissions in ports from shipping are in Asia and Europe (58%), but this share is low compared to their share of port calls (70%). European ports have much less emi...

  18. Sea freight - Antwerp Port

    Directory of Open Access Journals (Sweden)

    NEACSU Nicoleta Andreea

    2017-01-01

    Full Text Available Shipping plays a vital role in achieving the movement of goods, both in terms of quantity and efficiency. This paper presents the role and advantages of shipping in the global economy and analyzes the development and Antwerp Port activity. Currently, the second most important trading port in Europe and 14th in the ranking of most important ports that handle containers worldwide, the Port of Antwerp, Belgium is a port in the heart of Europe, accessible to large sized vessels. 200 years of constructing infrastructure and logistics around the central location, as well as pressure from Rotterdam, that had an impact on the competitiveness of the port of Antwerp, all this led the port to occupy a leading position in the top rankings.

  19. Diagnostic accuracy of indirect laryngoscopy and x-ray neck in the diagnosis of fish bone impaction in upper aero digestive tract

    International Nuclear Information System (INIS)

    Kundi, N.; Mehmood, T.

    2015-01-01

    This study was aimed at finding the validity of indirect laryngoscopy (IDL) and neck X-Rays in the diagnosis of fish bone impaction. Study Design: Validation study. Place and Duration of Study: CMH Nowshera from August 2012 to February 2013. Material and Methods: A total of 50 patients were selected by consecutive sampling presenting with history of fishbone impaction in aerodigestive tract. IDL examination and neck X-rays were performed and findings were recorded. Those with no fishbone on both the investigations were discharged from hospital with follow up after 03 days. Those with fishbone detected on either of investigations underwent removal. Fishbone easily approachable were removed under local anaesthesia with foreceps and in others Endoscopy (Direct laryngoscopy or Oesophagoscopy) was performed under General Anaesthesia. Sensitivities and specificities of both the modalities were calculated using standard 2/2 Table. ROC curve analysis was carried out and significance level p < 0.05 was taken as significant. Results: In 20 patients no fishbone was found, 26 patients were diagnosed on IDL and in 04 patients fishbone was detected by neck X-Rays. Most common site for fishbone impaction was pharyngeal tonsil. In 22 patients fishbone was removed with foreceps and in 08 patients endoscopy was performed. Diagnostic accuracy for IDL 86% and Neck X-Rays 48% was calculated. ROC curve analysis revealed AUC for IDL 0.933 and Significance level (P) as <0.0001. ROC curve analysis for X-ray gives AUC of 0.567 and Significance level (p) 0.4132. Conclusion: IDL shows higher diagnostic accuracy than neck X-Rays for detection of fishbone in upper aerodigestive tract. Neck X-rays are more useful for impacted foreign bodies in oesophagus. (author)

  20. Spatial Determinants of Import Traffic Distribution At Port Harcourt (Nigeria

    Directory of Open Access Journals (Sweden)

    Soddy I. Inyang

    2013-07-01

    Full Text Available This paper highlights the result of a study carried out to examine the Geographic determinants of import traffic distribution at the Port Harcourt Port. A substantial aspect of the study involved building a regression model to estimate import distribution from the Port. The import function was specified in log-linear form. The adequacy of the model was then tested; this, involved statistical experiments to obtain the R-squared, as well as t and f values. Further test on the adequacy of the nwdel was conducted through diagnostic exercises designed to check for inulticollinedrity and heteroscedasticity, in the data used. Results obtained show that road distance and manufacturing industries are significant Geographic determinants of import Cargo distribution at the study Port. It is therefore important to lake the two variables into account in any policy or planning exercise at Port Harcourt Port.

  1. Major aspects of the design of a first mirror for the ITER core CXRS diagnostics

    International Nuclear Information System (INIS)

    Krasikov, Yury; Panin, Anatoly; Biel, Wolfgang; Krimmer, Andreas; Litnovsky, Andrey; Mertens, Philippe; Neubauer, Olaf; Schrader, Michael

    2015-01-01

    Highlights: • Availability, technological issues, and changes in the ScMo structure to be solved in future. • Developed passively cooled mirror is a workable, flexible, scalable and robust concept. • The generic upper port plug is to be considerable customized. - Abstract: The ITER core charge exchange recombination spectroscopy diagnostics (cCXRS) occupies the vacuum vessel upper port #3 and includes, in its generic version, the following in-vessel components: an optical mirror system, a shutter, the diagnostic first wall and the neutron shielding block. The most vulnerable diagnostic mirror is obviously the first one (M1) directly observing the plasma. The M1 reference option is made of a single crystalline molybdenum (ScMo). The paper indicates major aspects influencing the first mirror design and identifies the most reasonable and reliable concept for cCXRS M1 at present. The applicability of the option presented is determined by many reasons, and especially, by the ITER generic upper port plug and its customization flexibility. The largest dimension of the mirror polished face is ∼300 mm. Such large ScMo workpieces are currently not available on the market. The mirror should be designed as an assembly of several ScMo pieces joined together. The M1 design is supported by multifield thermal, electromagnetic and structural analyses. The performed study confirms the feasibility of the proposed solutions. At the same time, the paper indicates numerous technological issues of the M1 unit to be solved in future.

  2. Major aspects of the design of a first mirror for the ITER core CXRS diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Krasikov, Yury, E-mail: y.krasikov@fz-juelich.de; Panin, Anatoly; Biel, Wolfgang; Krimmer, Andreas; Litnovsky, Andrey; Mertens, Philippe; Neubauer, Olaf; Schrader, Michael

    2015-10-15

    Highlights: • Availability, technological issues, and changes in the ScMo structure to be solved in future. • Developed passively cooled mirror is a workable, flexible, scalable and robust concept. • The generic upper port plug is to be considerable customized. - Abstract: The ITER core charge exchange recombination spectroscopy diagnostics (cCXRS) occupies the vacuum vessel upper port #3 and includes, in its generic version, the following in-vessel components: an optical mirror system, a shutter, the diagnostic first wall and the neutron shielding block. The most vulnerable diagnostic mirror is obviously the first one (M1) directly observing the plasma. The M1 reference option is made of a single crystalline molybdenum (ScMo). The paper indicates major aspects influencing the first mirror design and identifies the most reasonable and reliable concept for cCXRS M1 at present. The applicability of the option presented is determined by many reasons, and especially, by the ITER generic upper port plug and its customization flexibility. The largest dimension of the mirror polished face is ∼300 mm. Such large ScMo workpieces are currently not available on the market. The mirror should be designed as an assembly of several ScMo pieces joined together. The M1 design is supported by multifield thermal, electromagnetic and structural analyses. The performed study confirms the feasibility of the proposed solutions. At the same time, the paper indicates numerous technological issues of the M1 unit to be solved in future.

  3. Port Stakeholder Summit: Advancing More Sustainable Ports (April 2014)

    Science.gov (United States)

    EPA's National Port Stakeholders Summit, Advancing More Sustainable Ports, focused on actions to protect air quality while reducing climate risk and supporting economic growth, making ports more environmentally sustainable.

  4. Port Harcourt Medical Journal

    African Journals Online (AJOL)

    Port Harcourt Medical Journal's objectives are to disseminate medical information from the College of Health Sciences, University of Port Harcourt and the rest of the national and international medical community; act as a medium for the articulation of research and findings from same as well as proceedings of medical ...

  5. The Flexible Port

    NARCIS (Netherlands)

    Taneja, P.

    2013-01-01

    Ports are beset with many uncertainties about their futures. They are confronted with new demands in terms of functions and scales, new external constraints, and changed expectations. The inability to adequately meet these demands can mean costly adaptations for a port, or loss of cargo and

  6. Port Stakeholder Summit - April 2014

    Science.gov (United States)

    EPA's National Port Stakeholders Summit, Advancing More Sustainable Ports, focused on actions to protect air quality while reducing climate risk and supporting economic growth, making ports more environmentally sustainable.

  7. Diagnostics on Z (invited)

    International Nuclear Information System (INIS)

    Nash, T. J.; Derzon, M. S.; Chandler, G. A.; Fehl, D. L.; Leeper, R. J.; Porter, J. L.; Spielman, R. B.; Ruiz, C.; Cooper, G.; McGurn, J.

    2001-01-01

    The 100 ns, 20 MA pinch-driver Z is surrounded by an extensive set of diagnostics. There are nine radial lines of sight set at 12 o above horizontal and each of these may be equipped with up to five diagnostic ports. Instruments routinely fielded viewing the pinch from the side with these ports include x-ray diode arrays, photoconducting detector arrays, bolometers, transmission grating spectrometers, time-resolved x-ray pinhole cameras, x-ray crystal spectrometers, calorimeters, silicon photodiodes, and neutron detectors. A diagnostic package fielded on axis for viewing internal pinch radiation consists of nine lines of sight. This package accommodates virtually the same diagnostics as the radial ports. Other diagnostics not fielded on the axial or radial ports include current B-dot monitors, filtered x-ray scintillators coupled by fiber optics to streak cameras, streaked visible spectroscopy, velocity interferometric system for any reflector, bremsstrahlung cameras, and active shock breakout measurement of hohlraum temperature. The data acquisition system is capable of recording up to 500 channels and the data from each shot is available on the Internet. A major new diagnostic presently under construction is the BEAMLET backlighter. We will briefly describe each of these diagnostics and present some of the highest-quality data from them

  8. The Windows serial port programming handbook

    CERN Document Server

    Bai, Ying

    2004-01-01

    The fundamentals of serial port communications. Serial port programming in ANSI C and Assembly languages for MS-DOS. Serial ports interface developed in VC++ 6.0. Serial port programming in Visual Basic. Serial port programming in LabVIEW. Serial port programming in MATLAB. Serial port programming in Smalltalk. Serial port programming in Java.

  9. COSIMA-ES-PORT

    DEFF Research Database (Denmark)

    Barfod, Michael Bruhn; Leleur, Steen

    2007-01-01

    This article describes the results of the research project – WP3 East-west, Interreg IIIB – concerning the de¬velop¬ment of a new composite decision model, COSIMA-ES-PORT, for the assessment of three pre-feasibility studies situated at the Port of Esbjerg: a road project, a railway project...... and a multimodal terminal. The three studies indicates that a new road connection to the Port of Esbjerg is a very profitable project due to large travel time savings, whereas a new railway connection is not economically viable. However, a new multimodal terminal is also a very profitable project. The COSIMA...

  10. Revisiting port pricing : a proposal for seven port pricing principles

    NARCIS (Netherlands)

    Van Den Berg, R.; De Langen, P.W.; Van Zuijlen, P.C.J.

    2017-01-01

    A review of seven large landlord port authorities around the world reveals a notable diversity of pricing structures. While port authorities increasingly act as commercial undertakings, port pricing often seems to be not driven by commercial considerations. In this paper, we argue that ports can be

  11. Oluvil Port Development Project

    DEFF Research Database (Denmark)

    Frigaard, Peter; Margheritini, Lucia

    Oluvil Port Development Project is the first development of a large port infrastructure in the entire eastern coastline of Sri Lanka. The project is supported by the Danish Foreign Ministry. Feasibility studies and detailed design studies were carried out by Lanka Hydraulic Institute Ltd during...... the years 1995 to 2003. The design was reviewed by COWI a/s. Construction of the port was started in 2008. MT Højgaard a/s acted as contractor. The outer breakwaters were constructed as first part of the project. During and after completion of the breakwaters a serious beach erosion and sand accumulation...... has been observed. Severe erosion is seen north of the harbour and some accumulation of sand is seen south of the harbour. On a sandy coastline like the one in Oluvil such erosion problems as observed are very typical. The report: Oluvil Port Development Project: Studies on Beach Erosion written...

  12. Multiple-port valve

    International Nuclear Information System (INIS)

    Doody, T.J.

    1978-01-01

    A multiple-port valve assembly is designed to direct flow from a primary conduit into any one of a plurality of secondary conduits as well as to direct a reverse flow. The valve includes two mating hemispherical sockets that rotatably receive a spherical valve plug. The valve plug is attached to the primary conduit and includes diverging passageways from that conduit to a plurality of ports. Each of the ports is alignable with one or more of a plurality of secondary conduits fitting into one of the hemispherical sockets. The other hemispherical socket includes a slot for the primary conduit such that the conduit's motion along that slot with rotation of the spherical plug about various axes will position the valve-plug ports in respect to the secondary conduits

  13. Slewing Port Jib Cranes

    OpenAIRE

    Boris Visočnik; Stojan Kravanja

    2002-01-01

    The paper presents slewing port cranes with a luffing jib. The advantages of slewing port jib cranes are high lifting capacities, high speeds of re-loading and excellent mobility since they are capable of load lifting, travelling, luffing and slewing. The paper gives a detailed description of their characteristics such as the highest reached load-carrying capacities, speeds of motion and accelerations. It also presents the crane assembly, driving mechanisms, loads and load cases, transport by...

  14. Peripheral Venous Access Ports: Outcomes Analysis in 109 Patients

    International Nuclear Information System (INIS)

    Bodner, Leonard J.; Nosher, John L.; Patel, Kaushik M.; Siegel, Randall L.; Biswal, Rajiv; Gribbin, Christopher E.; Tokarz, Robert

    2000-01-01

    Purpose: To perform a retrospective outcomes analysis of central venous catheters with peripheral venous access ports, with comparison to published data.Methods: One hundred and twelve central venous catheters with peripherally placed access ports were placed under sonographic guidance in 109 patients over a 4-year period. Ports were placed for the administration of chemotherapy, hyperalimentation, long-term antibiotic therapy, gamma-globulin therapy, and frequent blood sampling. A vein in the upper arm was accessed in each case and the catheter was passed to the superior vena cava or right atrium. Povidone iodine skin preparation was used in the first 65 port insertions. A combination of Iodophor solution and povidone iodine solution was used in the last 47 port insertions. Forty patients received low-dose (1 mg) warfarin sodium beginning the day after port insertion. Three patients received higher doses of warfarin sodium for preexistent venous thrombosis. Catheter performance and complications were assessed and compared with published data.Results: Access into the basilic or brachial veins was obtained in all cases. Ports remained functional for a total of 28,936 patient days. The port functioned in 50% of patients until completion of therapy, or the patient's expiration. Ports were removed prior to completion of therapy in 18% of patients. Eleven patients (9.9% of ports placed) suffered an infectious complication (0.38 per thousand catheter-days)-in nine, at the port implantation site, in two along the catheter. In all 11 instances the port was removed. Port pocket infection in the early postoperative period occurred in three patients (4.7%) receiving a Betadine prep vs two patients (4.2%) receiving a standard O.R. prep. This difference was not statistically significant (p = 0.9). Venous thrombosis occurred in three patients (6.8%) receiving warfarin sodium and in two patients (3%) not receiving warfarin sodium. This difference was not statistically significant

  15. Slewing Port Jib Cranes

    Directory of Open Access Journals (Sweden)

    Boris Visočnik

    2002-09-01

    Full Text Available The paper presents slewing port cra11es with a luffing jib.The advantages of slewing port jib cranes are high lifting capacities,high speeds of re-loading and excellent mobility since theyare capable of load lifting, travelling, luffing and slewing. Thepaper gives a detailed description of their characteristics suchas the highest reached load-canying capacities, speeds of motionand accelerations. It also presents the crane assembly,driving mechanisms, loads and load cases, transport by shipsand testing of lifting capacity. As a practical example the paperpresents the slewing port jib crane with the capacity of25!15!5 tat a 27/37/40 m radius made by the Slovenian companyMetalna Maribor for the shipyard 3. Maj, Rijeka, Croatia.

  16. HomePort

    DEFF Research Database (Denmark)

    Le Guilly, Thibaut; Olsen, Petur; Ravn, Anders Peter

    2013-01-01

    Ambient Intelligence systems use many sensors and actuators, with a diversity of networks, protocols and technologies which makes it impossible to access the devices in a common manner. This paper presents the HomePort software, which provides an open source RESTful interface to heterogeneous...... sensor networks, allowing a simple unified access to virtually any kind of protocol using well known standards. HomePort includes means to provide event notification, as well as a tracing mechanism. The software is implemented and we report on initial experiments and provide an evaluation that shows...

  17. Port entry arrangements

    International Nuclear Information System (INIS)

    Chicken, J.C.; King, M.A.

    1978-01-01

    The objective of the paper is to describe the safety scheme port authorities should establish to deal with any contingency that may result from the visit of a nuclear powered ship. The safety scheme should be devised to cover both normal operation and any accident conditions that could arise while the ship is in port. The paper is divided into three parts. The three parts being: background information, general instructions, and emergency procedures. The background information will describe the nature of the hazards a port authority has to be prepared to deal with, and the philosophical basis for a berthing policy. In the part dealing with general instructions the objective of the safety scheme will be described. Also this part will describe the composition of the Port Safety Panel, allocation of responsibilities, passage and berthing arrangements, general safety precautions, records required, and rescue arrangements. In the part dealing with emergency procedures the role of: the Ship's Master, Harbour Authorities, Local Police, and local Health Services are discussed. As an Appendix to the paper a copy of the safety scheme that has been devised for visits of nuclear merchant ships to Southampton is given

  18. Strategic port development

    DEFF Research Database (Denmark)

    Olesen, Peter Bjerg; Dukovska-Popovska, Iskra; Steger-Jensen, Kenn

    2012-01-01

    This paper proposes a framework for strategic development of a port’s collaboration with its hinterland. The framework is based on literature relevant to port development and undertakes market perspective by considering import/export data relevant for the region of interest. The series of steps...

  19. Ports and innovation

    NARCIS (Netherlands)

    Taneja, P.; Vellinga, T.; Van Schuylenburg, M.

    2012-01-01

    A volatile environment, dynamic markets, and challenges created by new environmental and social consideration demand innovative solutions. Innovation is the implementation of ideas to create value. It promises ports resilience into the future. In this paper we trace some recent successful

  20. Essays on Dry Ports

    NARCIS (Netherlands)

    G.G. Chandrakant (Gujar)

    2011-01-01

    textabstractDue to several reasons, currently the global supply chains are getting stretched further away into the hinterlands from the gateway seaports. This single fact enhances the importance of dry ports. It would not be against logic, to state that in coming times, as a result of ever-growing

  1. Port-wine stain

    Science.gov (United States)

    ... About MedlinePlus Show Search Search MedlinePlus GO GO About MedlinePlus Site Map FAQs Customer Support Health Topics Drugs & Supplements Videos & Tools Español You Are Here: Home → Medical Encyclopedia → Port-wine stain URL of this page: //medlineplus.gov/ency/ ...

  2. Optimization of costs of Port Operations in Nigeria: A Scenario For ...

    African Journals Online (AJOL)

    2013-03-01

    Mar 1, 2013 ... +Department of Maritime Management Technology,. Federal ... Abstract. This study attempts to optimize the cost of port operations in Nigeria. ..... Slack. Original Value. Lower. Bound. Upper Bound. Const. 1. 0. 685.7727. 672.

  3. Green Port / Eco Port Project - Applications and Procedures in Turkey

    Science.gov (United States)

    Akgul, Burak

    2017-12-01

    As being the heartlands of international trade, sea ports are the junction points of land and sea routes. The growth of global trade has led to the development of number and capacity as well as the service quality of ports. The policies and procedures applied during construction, operation and development of ports under development with environmental considerations scope has evolved in accordance with the needs of global trends. Although maritime transportation provides the most ecofriendly transportation method, the reduction of potential environmental threats and continuous improvement of ports and their vicinity is paramount from environmental concerns with regards to the international environmental standards. In the context of the study, national and international legal regulations governing the control of the environmental impacts of the activity groups causing pollution in Turkey based sea ports were viewed. In addition, the models applied during the measurement and documentation of environmental impacts were investigated. The most important aspects in terms of the effectiveness of the environmental management models are legal regulations. However, the standards applied at the ports without any legal obligation, such as EcoPorts applications, ISO 14001 standard, and the EMAS (Eco-Management and Audit Scheme) were sought in the scope of the study. The boundaries of the study were determined as the EU based Environmental Management Systems and the Green Port/Eco Port Project which is being administered by the Turkish Ministry of Transport, Maritime and Communication. “Marport”, which is Turkey’s first certified Green Port / Eco Port is designated as the experimental study site. In addition, the provisions in the ports of ESPO member countries are approached in order to compare the effectiveness and applicability of Green Port / Eco Port Project.

  4. Port Card Module

    International Nuclear Information System (INIS)

    Utes, M.

    1994-01-01

    The Port Card will be one link in the data acquisition system for the D0 Silicon Vertex Detector. This system consists of the following parts, starting at the detector: Silicon strip detectors are mounted in a spaceframe and wire-bonded to custom bare-die integrated circuits (SVX-II chips) that digitize the charge collected by the strips. The 128-channel chips are mounted on a High-Density Interconnect (HDI) that consists of a small flex circuit that routes control signals and eight data bits for each of three to ten chips onto a common data bus. A cable then routes this bus approximately thirty feet out from the detector to the Port Card. The Port Card houses a commercial chipset that serializes the data in real time and converts the signal into laser light impulses that are then transmitted through a multi-mode optical fiber about 150 feet to a Silicon Acquisition and Readout board (SAR). Here, the data is transformed back to parallel electrical signals that are stored in one of several banks of FIFO memories. The FIFOs place their data onto the VME backplane to a VME Buffer Driver (VBD) which stores the event data in buffers for eventual readout over a thirty-two signal ribbon cable to the Level Two Computers and subsequent tape storage. Control and sequencing of the whole operation starts with the Silicon Acquisition/Readout Controller (SARC) working in tandem with the D0 Clock System. The SARC resides in the same VME crate as the SARs, and transforms signals from the Trigger System into control codes distributed to the various Port Cards via optical fibers operating at 53 Mb/s. It is through these control codes that data taking operations such as data-acquisition, digitization, readout, and various resets can be carried out. The Port Card receives the control codes and manipulates the SVX-II chips in the proper way to effect proper data taking. There will be a total of about 700,000 channels, which translates into about 5580 SVX-II chips, 66 to 100 Port Cards

  5. The Standard Deviation of Differential Index as an innovation diagnostic tool based on kinematic parameters for objective assessment of a upper limb motion pathology.

    Science.gov (United States)

    Jurkojć, Jacek; Wodarski, Piotr; Michnik, Robert A; Bieniek, Andrzej; Gzik, Marek; Granek, Arkadiusz

    2017-01-01

    Indexing methods are very popular in terms of determining the degree of disability associated with motor dysfunctions. Currently, indexing methods dedicated to the upper limbs are not very popular, probably due to difficulties in their interpretation. This work presents the calculation algorithm of new SDDI index and the attempt is made to determine the level of physical dysfunction along with description of its kind, based on the interpretation of the calculation results of SDDI and PULMI indices. 23 healthy people (10 women and 13 men), which constituted a reference group, and a group of 3 people with mobility impairments participated in the tests. In order to examine possibilities of the utilization of the SDDI index the participants had to repetitively perform two selected rehabilitation movements of upper extremities. During the tests the kinematic value was registered using inertial motion analysis system MVN BIOMECH. The results of the test were collected in waveforms of 9 anatomical angles in 4 joints of upper extremities. Then, SDDI and PULMI indices were calculated for each person with mobility impairments. Next, the analysis was performed to check which abnormalities in upper extremity motion can influence the value of both indexes and interpretation of those indexes was shown. Joint analysis of the both indices provides information on whether the patient has correctly performed the set sequence of movement and enables the determination of possible irregularities in the performance of movement given.

  6. Effects of noise-induced hearing loss within Port Harcourt metropolis ...

    African Journals Online (AJOL)

    This paper investigates the effects of Noise-Induced Hearing Loss within Port Harcourt Metropolis using a micro-controlled diagnostic audiometer (Kamplex KLD21).The data was obtained at two specific locations namely: Rivers State University of Science and Technology and Port Harcourt International Airport.

  7. Port interface requirements

    International Nuclear Information System (INIS)

    O'Neil, R.

    1978-01-01

    In a land-based reactor programme the Administration are usually confronted with a specific design in a particular environment. Safety and Reliability criteria necessary to the designer can be specified on the basis of acceptable risk to the population. However for the successful implementation of a nuclear ship programme on a broad commercial basis it is necessary to have agreed standards of risks from ships yet to be designed and agreed standards of acceptable risks to the population at likely ports of call yet to be specified, consulted, or agreed. At first sight it would seem that this double uncertainty must either lead to unnecessarily high safety standards for the ship or unacceptably conservative standards for berth selection. The paper discusses the problem and proposes a possible solution based on the concept of a 'Standard Port' and a 'Standard Ship' and indicates the level of risk implied by such a concept

  8. Handling of waste in ports

    International Nuclear Information System (INIS)

    Olson, P.H.

    1994-01-01

    The regulations governing the handling of port-generated waste are often national and/or local legislation, whereas the handling of ship-generated waste is governed by the MARPOL Convention in most parts of the world. The handling of waste consists of two main phases -collection and treatment. Waste has to be collected in every port and on board every ship, whereas generally only some wastes are treated and to a certain degree in ports and on board ships. This paper considers the different kinds of waste generated in both ports and on board ships, where and how it is generated, how it could be collected and treated. The two sources are treated together to show how some ship-generated waste may be treated in port installations primarily constructed for the treatment of the port-generated waste, making integrated use of the available treatment facilities. (author)

  9. Right upper quadrant pain

    International Nuclear Information System (INIS)

    Ralls, P.W.; Colletti, P.M.; Boswell, W.D. Jr.; Halls, J.M.

    1984-01-01

    Historically, assessment of acute right upper quadrant abdominal pain has been a considerable clinical challenge. While clinical findings and laboratory data frequently narrow the differential diagnosis, symptom overlap generally precludes definitive diagnosis among the various diseases causing acute right upper quadrant pain. Fortunately, the advent of newer diagnostic imaging modalities has greatly improved the rapidity and reliability of diagnosis in these patients. An additional challenge to the physician, with increased awareness of the importance of cost effectiveness in medicine, is to select appropriate diagnostic schema that rapidly establish accurate diagnoses in the most economical fashion possible. The dual goals of this discussion are to assess not only the accuracy of techniques used to evaluate patients with acute right upper quadrant pain, but also to seek out cost-effective, coordinated imaging techniques to achieve this goal

  10. A review of dry ports

    OpenAIRE

    Violeta Roso; Kent Lumsden

    2010-01-01

    The objective of this article is to present the previous research on the dry port concept and to review the world's existing dry ports, that is freight terminals that use the term ‘dry port’ in their name. Therefore, the purpose of this article is to clarify the concept by showing potential discrepancies or agreements between theory and practice. Starting from a literature review on the dry port concept, this article presents a review of existing dry ports in the world. A number of qualitativ...

  11. DIII-D in-vessel port cover and shutter assembly for the phase contrast interferometer

    International Nuclear Information System (INIS)

    Phelps, R.D.

    1994-01-01

    The entire outer wall of the DIII-D vacuum vessel interion is covered with a regular array of graphite tiles. Certain of the diagnostic ports through the outer vessel wall contain equipment which is shielded from the plasma by installing port covers designed to withstand energy deposition. If the diagnostic contained in the port must communicate with the vessel volume, a shutter assembly is usually provided. In the ports at 285 degrees, R+1 and R-1, interferometer mirrors have been installed to provide a means for transmitting a large diameter CO-2 laser beam through the edge of the plasma. To protect the mirrors and other hardware contained in these ports, a special protective plate and shutter arrangement has been designed. This report describes the details of design, fabrication, and installation of these protective covers and shutters

  12. Diagnostic planning in JT-60 project

    International Nuclear Information System (INIS)

    Matoba, Tohru; Suzuki, Yasuo; Funahashi, Akimasa; Itagaki, Tokiyoshi

    1977-08-01

    The diagnostic plans of JT-60 were made along with design of the main machine. Basic requirements of the diagnostic program are (1) multiple measurement of respective plasma parameters, (2) efficient usage of the discharge, (3) capable data acquisition system, (4) high reliability of the diagnostic equipments, and (5) systematic development of new diagnostic techniques. Dimensions of the diagnostic ports were determined in detailed design of the vacuum vessel, anticipating the possible diagnostic methods. The proposed diagnostic systems and the plans are shown in table and figures respectively. Problems in the diagnostics are also described. (auth.)

  13. 360 PORT MDA - A Strategy to Improve Port Security

    Science.gov (United States)

    2006-09-01

    Participating Agencies (After: Executive Briefing..........................27 Table 6. Designated Joint Operations Center Participants (From: SAFE...Investigations CGIP Coast Guard Intelligence Program CHOC Charleston Harbor Operations Center CIO Command Intelligence Officer CMT Combating Maritime... EXECUTIVE SUMMARY Ports are critical to our economy and national security. Key hubs in the international trade network, U.S. ports accounted for more than

  14. Conceptual Model Development of Sustainability Practices: The Case of Port Operations for Collaboration and Governance

    Directory of Open Access Journals (Sweden)

    Dalwon Kang

    2017-12-01

    Full Text Available Sustainability practices in port operations are critical issue to achieve port sustainability involving economic, social and environmental issues. To assist ports to successfully implant sustainability practices into their operations, this paper conceptualized the structure of sustainability practices in international port operations, by clustering the relevant issues, empirically. Using 203 samples collected from port stakeholders in the major ports in Northeast Asia, multi-measurement items were analyzed on exploratory factor analysis in SPSS 21. Results generated a structure that consists of five sub-dimensions conceptualizing sustainability practices in the context of port operations. As operative practices to accommodate current and future demands in a port, the five-factor model clustering the relevant issues incorporate environmental technologies, process and quality improvement, monitoring and upgrading, communication and cooperation, and active participation. Providing useful insights for strategic agenda to assist ports to incorporate sustainability practices in their operations, the five-factor model offer both a descriptive and diagnostic management tool for future improvement in port operations.

  15. Container Traffic In European Ports

    Directory of Open Access Journals (Sweden)

    Elen Twrdy

    2004-03-01

    Full Text Available Over the last fifteen years the European transport markethas witnessed a growth of container traffic which today reachesapproximately 50 million TEU per year. From 1997 to 2002,container traffic in the northern European ports increased from14 to 20.6 million TEU per year, in the ports of the westernMedite"anean from 6 to 10 million TEU per year, and in thenorthern Adriatic ports from 0. 69 to 0. 74 million TEU per year.The ports of the northern Adriatic are located in three states(Slovenia, Croatia and Italy with different statuses in relationto the common European market. In addition, different developmentlevels of these states are reflected in different levels ofinternational commercial exchange, the development of the existinginfrastructure and plans for the construction of new infrastructures.However, all three countries share a common goaltoincrease their competitiveness in comparison with the westemEuropean ports.

  16. Principles of subcutaneous port placement.

    Science.gov (United States)

    Gonda, Shaun J; Li, Ruizong

    2011-12-01

    The introduction of totally implantable subcutaneous devices in the early 1980s provided patients with secure, reliable venous access and also gave them the ability to move more freely and have a more normal lifestyle with these devices in place. The most common totally implantable device used today is the subcutaneous port. These ports consist of an injection port connected to a catheter. Ports provide a number of advantages compared with other venous catheters; the most important is the reduced risk of infection. These devices have significantly lower rates of infection than nontunneled and tunneled catheters. Additional advantages include less frequent irrigation and minimal home care, and they are less prone to environmental or cutaneous contamination when not being accessed. This article will focus on the placement of these ports. Copyright © 2011 Elsevier Inc. All rights reserved.

  17. Single-port laparoscopic partial splenectomy: a case report.

    Science.gov (United States)

    Hong, Tae Ho; Lee, Sang Kuon; You, Young Kyoung; Kim, Jun Gi

    2010-10-01

    With the better understanding of the importance of the spleen as a primary organ of the human immune system, there has been an increased interest in performing the partial splenectomy for a number of indications such as nonparasitic cysts, benign tumors, staging of lymphomas, etc. Moreover, laparoscopic partial splenectomy has been gaining more interest as the recommended approach for benign splenic disorders to preserve the splenic function with very low recurrence rates. Meanwhile, many surgeons have attempted to reduce the number and size of the ports in laparoscopic surgery with the aim of inducing less parietal trauma and fewer scars. One of these efforts is single-port laparoscopic surgery, which is a rapidly evolving field all over the world. Here, we describe a feasible method of single-port laparoscopic partial splenectomy for treating a benign splenic cyst that was located in the upper medial aspect of the spleen.

  18. Single port laparoscopic surgery

    DEFF Research Database (Denmark)

    Springborg, Henrik; Istre, Olav

    2012-01-01

    LESS, or laparo-endoscopic single site surgery, is a promising new method in minimally invasive surgery. An increasing number of surgical procedures are being performed using this technique, however, its large-scale adoption awaits results of prospective randomized controlled studies confirming...... potential benefits. Theoretically, cosmetic outcomes, postoperative pain and complication rates could be improved with use of single site surgery. This study describes introduction of the method in a private hospital in Denmark, in which 40 patients have been treated for benign gynecologic conditions....... Although the operations described are the first of their kind reported in Denmark, favorable operating times and very low complication rates are seen. It is the authors' opinion that in addition to being feasible for hysterectomy, single port laparoscopy may become the preferred method for many simple...

  19. 33 CFR 165.168 - Safety Zones; Coast Guard Captain of the Port New York Fireworks Displays.

    Science.gov (United States)

    2010-07-01

    ... of the Port New York Fireworks Displays. 165.168 Section 165.168 Navigation and Navigable Waters... Guard District § 165.168 Safety Zones; Coast Guard Captain of the Port New York Fireworks Displays. (a... Upper New York Bay within a 360-yard radius of the fireworks barge in approximate position 40°41′16.5″ N...

  20. Unsedated Flexible Upper Gastrointestinal Endoscopy: Need for ...

    African Journals Online (AJOL)

    Background: To determine the incidence of oxygen desaturation and whether routine oxygen monitoring is necessary during unsedated diagnostic flexible upper gastrointestinal endoscopy. Methods: A prospective study involving 54 consecutive in and out patients who had diagnostic upper gastrointestinal endoscopy at ...

  1. Modern diagnostic assessment of the upper urinary tract using multislice CT urography; Moderne Diagnostik des oberen Harntraktes mittels Mehrschicht-CT-Urographie

    Energy Technology Data Exchange (ETDEWEB)

    Kemper, J.; Adam, G.; Nolte-Ernsting, C. [Klinik und Poliklinik fuer Diagnostische und Interventionelle Radiologie, Universitaetsklinikum Hamburg-Eppendorf (Germany)

    2006-11-15

    The advent of Multislice Computed Tomography (MSCT) has made evaluation of the entire urinary tract with high-resolution sections during a single breath-hold a reality. Acquisition of multiple thin overlapping slices provides excellent two-dimensional (2D) and three-dimensional (3D) reformations of the urinary tract. The concept of 'Multislice CT Urography (MSCTU)' has emerged from this technical improvement. As a result, a wide range of pathologies inside and outside the urinary tract can be identified. During the last several years, MSCTU has challenged intravenous urography (IVU) in the evaluation of urinary tract abnormalities. Compared with IVU, MSCT(U) is more sensitive and specific in the detection and characterization of a variety of urinary tract disorders, including renal masses and urolithiasis. The main advantage of IVU has been its ability to offer excellent delineation of kidney basin cup system and ureteral anatomy and to depict subtle uroepithelial abnormalities. MSCTU has already shown promising results for overcoming this challenge. Optimal opacification and distension appear to be an essential requirement for a thorough evaluation of the collecting system. Dedicated preparation strategies have been developed to meet these technical difficulties. The biggest disadvantage of MSCTU is the significant radiation exposure. For broad routine clinical application, there is still a need for dose reduction protocols despite the ongoing technical developments in MSCTU. In this article, we outline the different concepts of technical processing for MSCTU and summarize the current role of MSCTU in the evaluation of the upper urinary tract. (orig.)

  2. Concerning background from calorimeter ports

    International Nuclear Information System (INIS)

    Digiacomo, N.J.

    1985-01-01

    Any detector system viewing a port or slit in a calorimeter wall will see, in addition to the primary particles of interest, a background of charged and neutral particles and photons generated by scattering from the port walls and by leakage from incompletely contained primary particle showers in the calorimeter near the port. The signal to noise ratio attainable outside the port is a complex function of the primary source spectrum, the calorimeter and port design and, of course, the nature and acceptance of the detector system that views the port. Rather than making general statements about the overall suitability (or lack thereof) of calorimeter ports, we offer here a specific example based on the external spectrometer and slit of the NA34 experiment. This combination of slit and spectrometer is designed for fixed-target work, so that the primary particle momentum spectrum contains higher momentum particles than expected in a heavy ion colliding beam environment. The results are, nevertheless, quite relevant for the collider case

  3. Developing the port of Belawan as a modern and international port

    Science.gov (United States)

    Many, N.

    2018-03-01

    This study discusses the processes of government to pass the port development plan in Indonesia with the Port of Belawan and its port expansion as the study case. The study uses a descriptive approach by reviewing and analyzing some of relevant literature as the sources. It also reviews and examines the port development theoretical concepts and models giving attention to the international hub port models resulted from the previous studies. The international hub port aspects assessed to be further applied and compared to the actual situation of the Port of Belawan. This process draws the conclusion on which concept and model the port classified, followed by some recommendations concerning the necessary actions to be taken. The results show that: (1) The port planning regulated in port master plan is the guideline and foundation to implement the port development; (2) Spatial and zoning plan regulations are very important in the preparation, planning, and implementation of port development; (3) It has not provided the necessary facilities and criteria of the global hub port model has not been met completely. The port is strategic to be completely developed as the regional hub port to compete with the major ports of neighboring countries. Eventually, this study requires further analysis to examine the economic feasibility of the Port of Belawan in more comprehensive way functioning as an international hub port along with the ongoing development of Kuala Tanjung Port to achieve its ultimate objectives, among other things, the port effectiveness, efficiency, and competitiveness.

  4. Concept development for the ITER equatorial port visible/infrared wide angle viewing system

    International Nuclear Information System (INIS)

    Reichle, R.; Beaumont, B.; Boilson, D.; Bouhamou, R.; Direz, M.-F.; Encheva, A.; Henderson, M.; Kazarian, F.; Lamalle, Ph.; Lisgo, S.; Mitteau, R.; Patel, K. M.; Pitcher, C. S.; Pitts, R. A.; Prakash, A.; Raffray, R.; Schunke, B.; Snipes, J.; Diaz, A. Suarez; Udintsev, V. S.

    2012-01-01

    The ITER equatorial port visible/infrared wide angle viewing system concept is developed from the measurement requirements. The proposed solution situates 4 viewing systems in the equatorial ports 3, 9, 12, and 17 with 4 views each (looking at the upper target, the inner divertor, and tangentially left and right). This gives sufficient coverage. The spatial resolution of the divertor system is 2 times higher than the other views. For compensation of vacuum-vessel movements, an optical hinge concept is proposed. Compactness and low neutron streaming is achieved by orienting port plug doglegs horizontally. Calibration methods, risks, and R and D topics are outlined.

  5. Detailed Design and Fabrication Method of the ITER Vacuum Vessel Ports

    International Nuclear Information System (INIS)

    Hee-Jae Ahn; Kwon, T.H.; Hong, Y.S.

    2006-01-01

    The engineering design of the ITER vacuum vessel (VV) has been progressed by the ITER International Team (IT) with the cooperation of several participant teams (PT). The VV and ports are the components allocated to Korea for the construction of the ITER. Hyundai Heavy Industries has been involved in the structural analysis, detailed design and development of the fabrication method of the upper and lower ports within the framework of the ITER transitional arrangements (ITA). The design of the port structures has been investigated to validate and to improve the conceptual designs of the ITER IT and other PT. The special emphasis was laid on the flange joint between the port extension and the in-port plug to develop the design of the upper port. The modified design with a pure friction type flange with forty-eight pieces of bolts instead of the tangential key is recommended. Furthermore, the alternative flange designs developed by the ITER IT have been analyzed in detail to simplify the lip seal maintenance into the port flange. The structural analyses of the lower RH port have been also performed to verify the capacity for supporting the VV. The maximum stress exceeds the allowable value at the reinforcing block and basement. More elaborate local models have been developed to mitigate the stress concentration and to modify the component design. The fabrication method and the sequence of the detailed fabrication for the ports are developed focusing on the cost reduction as well as the simplification. A typical port structure includes a port stub, a stub extension and a port extension with a connecting duct. The fabrication sequence consists of surface treatment, cutting, forming, cleaning, welding, machining, and non-destructive inspection and test. Tolerance study has been performed to avoid the mismatch of each fabricated component and to obtain the suitable tolerances in the assembly at the shop and site. This study is based on the experience in the fabrication of

  6. ITER diagnostics ex-vessel engineering services

    Energy Technology Data Exchange (ETDEWEB)

    Arumugam, A.P., E-mail: arun.prakash@iter.org; Walker, C.I.; Andrew, P.; Barnsley, R.; Beltran, D.; Bertalot, L.; Dammann, A.; Direz, M.F.; Drevon, J.M.; Encheva, A.; Giacomin, T.; Hourtoule, J.; Kuehn, I.; Lanza, R.; Levesy, B.; Maquet, P.; Patel, K.M.; Patisson, L.; Pitcher, C.S.; Portales, M.; and others

    2013-10-15

    Highlights: • This paper describes about the ITER diagnostics ex-vessel engineering services. • It describes various diagnostics systems, its location and its environment. • Diagnostics interfaces with other services such as the buildings, HVAC, electrical services, cooling water, vacuum, liquid and gas distribution. • All the interfaces with these services are identified and defined. • Buildings services for diagnostics, such as penetrations, local shielding, embedment and temperature control are discussed. -- Abstract: Extensive diagnostics systems will be installed on the ITER machine to provide the measurements necessary to control, evaluate and optimize plasma performance in ITER and to further the understanding of plasma physics. These include measurements of temperature, density, impurity concentration, and particle and energy confinement times. ITER diagnostic systems extend from the center of the Tokamak to the various diagnostic areas, where they are controlled and acquired data is processed. This mainly includes the areas such as ports, port cells, gallery, diagnostics enclosures and cubicle areas. The diagnostics port plugs encloses the front end of the diagnostic systems and the diagnostics building houses the diagnostics equipment, instrumentation and control cubicles. There are several systems providing services to diagnostics. These mainly include ITER buildings, electrical power services, cooling water services, Heating Ventilation and Air Conditioning (HVAC), vacuum services, liquid and gas distribution services, cable engineering, de-tritiation systems, control cubicles, etc. Requirements of these service systems have to be defined, even though many of the diagnostics are at an early stage of development. It is a real challenge to define and to design diagnostics systems considering the constraints imposed by these service systems. This paper summarizes the provision of these services to the individual diagnostics and diagnostics areas

  7. ITER diagnostics ex-vessel engineering services

    International Nuclear Information System (INIS)

    Arumugam, A.P.; Walker, C.I.; Andrew, P.; Barnsley, R.; Beltran, D.; Bertalot, L.; Dammann, A.; Direz, M.F.; Drevon, J.M.; Encheva, A.; Giacomin, T.; Hourtoule, J.; Kuehn, I.; Lanza, R.; Levesy, B.; Maquet, P.; Patel, K.M.; Patisson, L.; Pitcher, C.S.; Portales, M.

    2013-01-01

    Highlights: • This paper describes about the ITER diagnostics ex-vessel engineering services. • It describes various diagnostics systems, its location and its environment. • Diagnostics interfaces with other services such as the buildings, HVAC, electrical services, cooling water, vacuum, liquid and gas distribution. • All the interfaces with these services are identified and defined. • Buildings services for diagnostics, such as penetrations, local shielding, embedment and temperature control are discussed. -- Abstract: Extensive diagnostics systems will be installed on the ITER machine to provide the measurements necessary to control, evaluate and optimize plasma performance in ITER and to further the understanding of plasma physics. These include measurements of temperature, density, impurity concentration, and particle and energy confinement times. ITER diagnostic systems extend from the center of the Tokamak to the various diagnostic areas, where they are controlled and acquired data is processed. This mainly includes the areas such as ports, port cells, gallery, diagnostics enclosures and cubicle areas. The diagnostics port plugs encloses the front end of the diagnostic systems and the diagnostics building houses the diagnostics equipment, instrumentation and control cubicles. There are several systems providing services to diagnostics. These mainly include ITER buildings, electrical power services, cooling water services, Heating Ventilation and Air Conditioning (HVAC), vacuum services, liquid and gas distribution services, cable engineering, de-tritiation systems, control cubicles, etc. Requirements of these service systems have to be defined, even though many of the diagnostics are at an early stage of development. It is a real challenge to define and to design diagnostics systems considering the constraints imposed by these service systems. This paper summarizes the provision of these services to the individual diagnostics and diagnostics areas

  8. Case Studies: Improving Environmental Performance and Economic Prosperity at Ports and in Near-Port Communities

    Science.gov (United States)

    Case Study links for improving environmental performance and economic prosperity at ports and in near-port communities. Case studies on equipment upgrades, jobs and benefits, land use and transportation, port-community engagement, and citizen science.

  9. Applying HAZOP analysis in assessing remote handling compatibility of ITER port plugs

    International Nuclear Information System (INIS)

    Duisings, L.P.M.; Til, S. van; Magielsen, A.J.; Ronden, D.M.S.; Elzendoorn, B.S.Q.; Heemskerk, C.J.M.

    2013-01-01

    Highlights: ► We applied HAZOP analysis to assess the criticality of remote handling maintenance activities on port plugs in the ITER Hot Cell facility. ► We identified several weak points in the general upper port plug maintenance concept. ► We made clear recommendations on redesign in port plug design, operational sequence and Hot Cell equipment. ► The use of a HAZOP approach for the ECH UL port can also be applied to ITER port plugs in general. -- Abstract: This paper describes the application of a Hazard and Operability Analysis (HAZOP) methodology in assessing the criticality of remote handling maintenance activities on port plugs in the ITER Hot Cell facility. As part of the ECHUL consortium, the remote handling team at the DIFFER Institute is developing maintenance tools and procedures for critical components of the ECH Upper launcher (UL). Based on NRG's experience with nuclear risk analysis and Hot Cell procedures, early versions of these tool concepts and maintenance procedures were subjected to a HAZOP analysis. The analysis identified several weak points in the general upper port plug maintenance concept and led to clear recommendations on redesigns in port plug design, the operational sequence and ITER Hot Cell equipment. The paper describes the HAZOP methodology and illustrates its application with specific procedures: the Steering Mirror Assembly (SMA) replacement and the exchange of the Mid Shield Optics (MSO) in the ECH UPL. A selection of recommended changes to the launcher design associated with the accessibility, maintainability and manageability of replaceable components are presented

  10. Cooperation Performance Evaluation between Seaport and Dry Port; Case of Qingdao Port and Xi'an Port

    Directory of Open Access Journals (Sweden)

    Jian Li

    2014-12-01

    Full Text Available Along with the drastic competition among ports, the strive for the vast economic hinterland and the supply of goods have become strategic problems for port operators. At the same time, port enterprises are paying more and more attention to the construction of dry ports. This article establishes the port cooperation performance evaluation index based on the balanced score card method and uses the grey relational degree method to evaluate the cooperation performance between seaports and dry ports. Finally using Qingdao port and Xi'an port as an example, and Zhengzhou port and Lanzhou port as benchmarks, the application of this evaluation method is introduced in detail. The conclusion reveals that cooperation between Qingdao port and Xi'an port has deficiencies in customer satisfaction, financial cooperation and non-market tools. Alongside this, the author proposes related issues about information management in the supply chain, competition position and the scope of hinterland. This article, combined with the related theory of supply chain and performance evaluation, puts forward a set of relatively complete cooperation performance evaluations between seaports and dry ports, which provide scientific theory support for better cooperation.

  11. Interface Circuit For Printer Port

    Science.gov (United States)

    Tucker, Jerry H.; Yadlowsky, Ann B.

    1991-01-01

    Electronic circuit, called printer-port interface circuit (PPI) developed to overcome certain disadvantages of previous methods for connecting IBM PC or PC-compatible computer to other equipment. Has both reading and writing modes of operation. Very simple, requiring only six integrated circuits. Provides for moderately fast rates of transfer of data and uses existing unmodified circuit card in IBM PC. When used with appropriate software, circuit converts printer port on IBM PC, XT, AT, or compatible personal computer to general purpose, 8-bit-data, 16-bit address bus that connects to multitude of devices.

  12. Effectively reducing emissions from ports

    Energy Technology Data Exchange (ETDEWEB)

    Fazlagic, Ismir; Martelin, Marcus; Skinner, Ryan

    2010-09-15

    Commercial ships calling at more and more ports worldwide can now turn off their diesel engines and tap into cleaner energy sources provided by electrical connections from shore. The technology to make this possible has been in place for over a decade. With a global technology standard due to be ratified by three technical bodies in 2010, high-voltage shore connections will soon get much more attention. Environmentally-minded ports, governments and shipowners are all tuning in to the benefits of supplying electricity to ships at berth. ABB presents the challenge, the technical solution and the business case for all parties involved.

  13. Port Harcourt Medical Journal, a paradigm shift | Eke | Port Harcourt ...

    African Journals Online (AJOL)

    Port Harcourt Medical Journal, a paradigm shift. N Eke. Abstract. No Abstract. Full Text: EMAIL FULL TEXT EMAIL FULL TEXT · DOWNLOAD FULL TEXT DOWNLOAD FULL TEXT · http://dx.doi.org/10.4103/0795-3038.179439 · AJOL African Journals Online. HOW TO USE AJOL... for Researchers · for Librarians · for Authors ...

  14. The VisPort Project: Visualization of Port Logistics

    Science.gov (United States)

    Katsioloudis, Petros J.; Watson, Ginger

    2011-01-01

    There is concern about the diminishing availability of skilled personnel that can operate in the wide variety of disciplines associated with port operations. Increasing cargo volume, combined with a shrinking workforce, could potentially create alarming situations in the future, hence the motivation to publicize to current students the breadth and…

  15. Ports Primer: 7.1 Environmental Impacts

    Science.gov (United States)

    Port operations can lead to environmental impacts on air, water and land. Many communities with environmental justice concerns also experience disparities in health outcomes that they attribute to exposure to emissions from port operations.

  16. Ports Primer: 7.0 Environmental Impacts

    Science.gov (United States)

    Port operations can lead to environmental impacts on air, water and land. Many communities with environmental justice concerns also experience disparities in health outcomes that they attribute to exposure to emissions from port operations.

  17. Single port Billroth I gastrectomy

    Directory of Open Access Journals (Sweden)

    Jeremy R Huddy

    2013-01-01

    Full Text Available Introduction: Experience has allowed increasingly complex procedures to be undertaken by single port surgery. We describe a technique for single port Billroth I gastrectomy with a hand-sewn intracorporeal anastomosis in the resection of a benign tumour diagnosed incidentally on a background of cholelithiasis. Materials and Methods: Single port Billroth I gastrectomy and cholecystectomy was performed using a transumbilical quadport. Flexible tipped camera and straight conventional instruments were used throughout the procedure. The stomach was mobilised including a limited lymph node dissection and resection margins in the proximal antrum and duodenum were divided with a flexible tipped laparoscopic stapler. The lesser curve was reconstructed and an intracorporal hand sewn two layer end-to-end anastomosis was performed using unidirectional barbed sutures. Intraoperative endoscopy confirmed the anastomosis to be patent without leak. Results: Enteral feed was started on the day of surgery, increasing to a full diet by day 6. Analgesic requirements were a patient-controlled analgesia morphine pump for 4 postoperative days and paracetamol for 6 days. There were no postoperative complications and the patient was discharged on the eighth day. Histology confirmed gastric submucosal lipoma. Discussion: As technology improves more complex procedures are possible by single port laparoscopic surgery. In this case, flexible tipped cameras and unidirectional barbed sutures have facilitated an intracorporal hand-sewn two layer end-to-end anastomosis. Experience will allow such techniques to become mainstream.

  18. Port Harcourt Medical Journal: Submissions

    African Journals Online (AJOL)

    Port Harcourt Medical Journal (PMJ) is a general medical journal that will consider any original contribution that advances or illuminates medical science or ... The covering letter must include information on prior or duplicate publication and a statement of financial or other relationships that might lead to a conflict of interest.

  19. Cyber security in ports: Business as usual

    OpenAIRE

    Moerel, Lokke; Dezeure, Freddy

    2017-01-01

    Our paper summarizes the risks and provides concrete and pragmatic proposals to increase substantially the cyber maturity and resilience in the ports by organizing training and awareness raising, fostering cooperation and information exchange both between the stakeholders in the ports and across the ports and integrating the cyber risk into the physical security risk management processes and structures already in place within the ports. This also involves a higher degree of oversight by the P...

  20. COMPARATIVE ANALYSIS OF LEADING PORTS OF LATVIA: COMPETITIVENESS OF LIEPAJA PORT

    Directory of Open Access Journals (Sweden)

    Diāna Līduma

    2015-06-01

    Full Text Available There are 10 operating ports in Latvia and 3 of them – Liepaja, Ventspils and Riga ports are regarded as the leading commercial ports. Role of port operation in the economics of region and country is essential from the point of view of employment and entrepreneurship. This is based with data on investment of operation of Latvian ports in GDP, on average it is assessed to be 5-7% annually. In the context of employment, Liepaja Port gives work to 6.9% of human resources of the city. However, concern about the competitiveness of Liepaja Port influenced by the proximity of more developed competitive ports, technical possibilities of the port and dynamics of freight turnover has occurred in recent years. Therewith in framework of this article in the context of such criteria as location of ports and their technical parameters, volumes of freight, specialization and costs of ports, the operation of leading ports of Latvia is intercompared and analyzed by clarifying whether Liepaja Port is competitive among other ports of Latvia. Opinions of port experts on perspectives of port development and statistical data of ports from 2011-2013 are analyzed within the framework of the article. The aim of the research is to clarify the comparative advantages of ports of Latvia. The research revealed that the provision of competitiveness of Liepaja Port is to be related with application of the available free territories, advantages of location in relation to the Scandinavian market, and the necessity to develop the cooperation among ports of Latvia to offer joint freight acquisition, distributions and unified logistics solution and strengthen the position of ports in the circumstances of international competition.

  1. Parametric decay below the upper hybrid frequency

    Energy Technology Data Exchange (ETDEWEB)

    Albers, E; Krause, K; Schlueter, H [Bochum Univ. (Germany, F.R.). Inst. fuer Experimentalphysik 2

    1977-03-21

    Parametric decay of the upper hybrid mode is observed between the electron cyclotron frequency and its first two harmonics. The decay products are identified as electron Bernstein and ion acoustic mode. The diagnostic results confirm the relevant dispersion relations.

  2. Multi-functional use of port areas

    NARCIS (Netherlands)

    Ros, R.; Taneja, P.; Vellinga, T.

    2012-01-01

    The core business of a port is handling vessels and cargo. In addition a landlord Port Authority invests in development of port areas. However, in view of the new trends such as stakeholders interests related to environment and sustainability, it is can be wise to reexamine the business portfolio

  3. Systems theory of interconnected port contact systems

    NARCIS (Netherlands)

    Eberard, D.; Maschke, B.M.; Schaft, A.J. van der

    2005-01-01

    Port-based network modeling of a large class of complex physical systems leads to dynamical systems known as port-Hamiltonian systems. The key ingredient of any port-Hamiltonian system is a power-conserving interconnection structure (mathematically formalized by the geometric notion of a Dirac

  4. 50 CFR 24.12 - Designated ports.

    Science.gov (United States)

    2010-10-01

    ...) The U.S. Department of Agriculture ports at Hilo, Hawaii, and Chicago, Illinois, are designated ports..., Florida Atlanta, Georgia Savannah, Georgia Agana, Guam Hilo, Hawaii Honolulu, Hawaii Wailuku, Maui, Hawaii... Orlando, Florida Honolulu, Hawaii New Orleans, Louisiana Hoboken, New Jersey (Port of New York) Jamaica...

  5. Notch filters for port-Hamiltonian systems

    NARCIS (Netherlands)

    Dirksz, D.A.; Scherpen, J.M.A.; van der Schaft, A.J.; Steinbuch, M.

    2012-01-01

    In this paper a standard notch filter is modeled in the port-Hamiltonian framework. By having such a port-Hamiltonian description it is proven that the notch filter is a passive system. The notch filter can then be interconnected with another (nonlinear) port-Hamiltonian system, while preserving the

  6. Conservative systems with ports on contact manifolds

    NARCIS (Netherlands)

    Eberard, D.; Maschke, B.M.; van der Schaft, Arjan; Piztek, P.

    In this paper we propose an extension of port Hamiltonian systems, called conservative systems with ports, which encompass systems arising from the Irreversible Thermodynamics. Firstly we lift a port Hamiltonian system from its state space manifold to the thermodynamic phase space to a contact

  7. Ports and Terminals : Planning and Functional Design

    NARCIS (Netherlands)

    Groenveld, R.; Velsink, H.

    1993-01-01

    1. Maritime transport, means and commodities 3. Principles of integrated port planning 4. Planning and design of a port's water areas 5. Port terminals - introduction 6. Conventional general cargo terminals 7. Container terminals 8. Oil & liquid gas terminals 9. Dry bulk cargo terminals 10. Fishery

  8. Port-contact systems in bilateral telemanipulation

    NARCIS (Netherlands)

    Secchi, C; Stramigioli, Stefano; Fantuzzi, C.

    2007-01-01

    In this paper we develop one of the first control applications of the recently proposed port-contact framework. We show how it is possible to model and control a bilateral telemanipulation system using port-contact systems and we develop a port-contact impedance controller that allows to impose a

  9. Evaluating export container pooling options in MN, WI, and MI's Upper Peninsula.

    Science.gov (United States)

    2013-04-01

    Research was undertaken to investigate the issues impacting the expansion of containerized cargo in : Wisconsin, Minnesota and the Upper Peninsula of Michigan. Best practices in container pooling, load matching, : inland ports and electronic tracking...

  10. Perancangan Miniatur Traffic Light Dengan Mempergunakan Pengendali Port Paralel

    OpenAIRE

    Eka Wahyudi; Desi Permanasari

    2012-01-01

    Port paralel tentunya sudah tidak asing lagi dalam dunia komputer. Hal tersebut disebabkan karena port paralel merupakan sarana komunikasi yang terdapat pada Personal Computer (PC). Dengan memanfaatkan port tersebut, saat ini komputer juga dapat dipergunakan untuk keperluan pengontrolan/pengendalian rangkaian listrik dengan memanfaatkan port paralel (port printer). Port paralel memiliki kecepatan transfer data yang lebih cepat apabila dibandingkan dengan port serial, maka dari itu port parale...

  11. FASTBUS Snoop Diagnostic Module

    International Nuclear Information System (INIS)

    Walz, H.V.; Downing, R.

    1980-11-01

    Development of the FASTBUS Snoop Module, undertaken as part of the prototype program for the new interlaboratory data bus standard, is described. The Snoop Module resides on a FASTBUS crate segment and provides diagnostic monitoring and testing capability. Communication with a remote host computer is handled independent of FASTBUS through a serial link. The module consists of a high-speed ECL front-end to monitor and single-step FASTBUS cycles, a master-slave interface, and a control microprocessor with serial communication ports. Design details and performance specifications of the prototype module are reported. 9 figures, 1 table

  12. 78 FR 36014 - Deepwater Port License Application: Liberty Natural Gas, LLC, Port Ambrose Deepwater Port

    Science.gov (United States)

    2013-06-14

    ... timeline for processing an application. When MarAd and USCG determine that an application contains the... that Port Ambrose falls within the proposed area of interest for the New York Power Authority Long Island-New York City Offshore Wind Project. This project will be acknowledged and considered in the...

  13. Maintaining and Researching Port Safety: A Case Study of the Port of Kaohsiung

    OpenAIRE

    Tseng, Po-Hsing.; Pilcher, Nick.

    2017-01-01

    Maintaining port safety in full conformity with IMO standards is a requisite for every port and country. To do this, understanding the challenges and human factors involved is key. To date, much research has shed valuable light on these factors and considered how to address them. One aspect that is often noted is that both maintaining port safety and researching port safety presents numerous challenges. This paper considers both these aspects in the context of a case study of port safety in K...

  14. Vaginoscopy in Ewes Utilizing a Laparoscopic Surgical Port Device

    Directory of Open Access Journals (Sweden)

    Jeremiah Easley

    2017-01-01

    Full Text Available Vaginoscopy allows for diagnostic evaluation and treatment of the vaginal vault. A laparoscopic surgical port device and rigid telescope were utilized for serial vaginoscopy in 8 healthy anesthetized ewes. Vaginoscopy examinations were performed in each ewe at days 1, 14, and 28. This technique was well-tolerated and facilitated carbon dioxide vaginal inflation, complete vaginal examination, identification of the cervix, and targeted biopsy collection. No complications were encountered during or following the vaginoscopy procedures. The laparoscopic port device was well-suited to the ewe vulvar size. This technique could be applied to clinical evaluation in ewes for the purposes of examination, biopsy, culture, foreign body removal, and minor surgical procedures.

  15. Hub Status and Indexation of Container Ports

    Directory of Open Access Journals (Sweden)

    Yong-An Park

    2015-06-01

    This study develops two sub-indexes of port classification and capacity, and combines cases of these two sub-indexes into various types in order to find a proper port hub index. The paper demonstrates how different types of port hub index are useful measurements for evaluating outputs and inputs of container ports. In a case analysis we show that the indexes of period variables and lagged variables have more explanatory power with regard to changes of port throughputs and high correlation with inputs.

  16. 75 FR 39839 - Regulated Navigation Area; Hudson River and Port of NY/NJ

    Science.gov (United States)

    2010-07-13

    ... navigation area (RNA) from Port Coeymans, New York on the Hudson River to Jersey City, New Jersey on Upper... replacement span. DATES: This rule is effective from July 13, 2010 through October 31, 2010. The RNA will be... time and place announced by a later notice in the Federal Register. [[Page 39840

  17. Status of the R&D activities to the design of an ITER core CXRS diagnostic system

    Energy Technology Data Exchange (ETDEWEB)

    Mertens, Philippe, E-mail: ph.mertens@fz-juelich.de [Institute of Energy and Climate Research IEK-4 (Plasma Physics), Forschungszentrum Jülich (FZJ), Trilateral Euregio Cluster, D-52425 Jülich (Germany); Castaño Bardawil, David A. [Institute of Energy and Climate Research IEK-4 (Plasma Physics), Forschungszentrum Jülich (FZJ), Trilateral Euregio Cluster, D-52425 Jülich (Germany); Baross, Tétény [Wigner Research Centre for Physics (Wigner RCP), HU-1121 Budapest (Hungary); Biel, Wolfgang; Friese, Sebastian [Institute of Energy and Climate Research IEK-4 (Plasma Physics), Forschungszentrum Jülich (FZJ), Trilateral Euregio Cluster, D-52425 Jülich (Germany); Hawkes, Nick [Culham Centre for Fusion Energy (CCFE), Culham OX14 3DB (United Kingdom); Jaspers, Roger J.E. [Eindhoven University of Technology (TU/e), PO Box 513, NL-5600 MB Eindhoven (Netherlands); Kotov, Vladislav; Krasikov, Yury; Krimmer, Andreas; Litnovsky, Andrey; Marchuk, Oleksander; Neubauer, Olaf [Institute of Energy and Climate Research IEK-4 (Plasma Physics), Forschungszentrum Jülich (FZJ), Trilateral Euregio Cluster, D-52425 Jülich (Germany); Offermanns, Guido [Zentralinstitut für Engineering, Elektronik und Analytik ZEA-1 (Engineering and Technology), FZJ, Trilateral Euregio Cluster, D-52425 Jülich (Germany); Panin, Anatoly [Institute of Energy and Climate Research IEK-4 (Plasma Physics), Forschungszentrum Jülich (FZJ), Trilateral Euregio Cluster, D-52425 Jülich (Germany); and others

    2015-10-15

    Highlights: • The CXRS diagnostic for the core plasma of ITER will provide observation of the dedicated diagnostic beam (DNB) over a wide radial range, roughly r/a = 0.7 to 0. • A high performance (étendue × transmission, dynamic range) is expected for the port plug system since the beam attenuation is large and the background light omnipresent. • The design is particularly challenging in view of the ITER environment, especially with respect to the first mirror which faces the plasma. • The current status of development is presented by detailing several sub-systems before a four years design phase under an FPA between F4E and the ITER core CXRS Consortium (IC3). - Abstract: The CXRS (Charge-eXchange Recombination Spectroscopy) diagnostic for the core plasma of ITER will be designed to provide observation of the dedicated diagnostic beam (DNB) over a wide radial range, roughly from a normalised radius r/a = 0.7 to close to the plasma axis. The collected light will be transported through the Upper Port Plug #3 (UPP3) to a bundle of fibres and ultimately to a set of remote spectrometers. The design is particularly challenging in view of the ITER environment of particle, heat and neutron fluxes, temperature cycles, electromagnetic loads, vibrations, expected material degradation and fatigue, constraints against tritium penetration, integration in the plug and limited opportunities for maintenance. Moreover, a high performance (étendue × transmission, dynamic range) is expected for the port plug system since the beam attenuation is large and the background light omnipresent, especially in terms of bremsstrahlung, line radiation and reflections. The present contribution will give an overview of the current status and activities which deal with the core CXRS system, summarising the investigations which have taken place before entering the actual development and design phase.

  18. Upper High School Students' Understanding of Electromagnetism

    Science.gov (United States)

    Saglam, Murat; Millar, Robin

    2006-01-01

    Although electromagnetism is an important component of upper secondary school physics syllabuses in many countries, there has been relatively little research on students' understanding of the topic. A written test consisting of 16 diagnostic questions was developed and used to survey the understanding of electromagnetism of upper secondary school…

  19. Determinants of Port Performance - Case Study of 4 Main Ports in Indonesia (2005-2015

    Directory of Open Access Journals (Sweden)

    Atika Aqmarina

    2018-03-01

    Full Text Available Port plays significant role in supporting economic growth of a country. This study aims to analyze the determinant of port performance in Indonesia. In this research, the ports selected are four main ports in Indonesia which are Port of Belawan, Port of Tanjung Priok, Port of Tanjung Perak, and Makassar. These ports are designed as the hub ports in the national sea transport system of the country. The study used pooled OLS as the methodology to analyze the determinant. The result of this studies shows that total traffic is not influenced by operating surplus per ton, whereas the rest of variables such as turnaround time, idle time, berth of occupancy rate, rate of return, number of employee and cargo equipment have significant results and significantly influenced the total traffic.

  20. Tourist Ports and Yachting: The Case of Sardinia

    Directory of Open Access Journals (Sweden)

    Gian Marco Ugolini

    2017-12-01

    Full Text Available The aim of this work is to describe the situation of nautical tourism in one of the largest islands in the Mediterranean through the analysis of the marinas and the sailing habits of the boaters. After outlining the typology, characteristics and functions of the marinas in the introduction, we briefly present the quantitative-qualitative analysis methodology that was carried out through interviews to the stakeholders and subsequent processing of the original information obtained. The presentation of the results concerns the context of Italian ports and then focuses on Sardinia in terms of ports and berths. The discussion, on the other hand, is based on the original analysis of the use of Sardinian ports, the navigation mode of the boaters, including the characteristics of the boats used. In the conclusions, it is emphasized that Sardinia is at the centre of a boating area that extends to the Upper Tyrrhenian Sea, within which it represents a hub and the favourite area for the most important and rich segment of yachts. This, however, does not preclude existing structures from pursuing an improvement in the supply from the point of view of environmental compatibility, of the quality of the services offered and, above all, of a stronger connection to the tourist offer of the hinterlands. A possible development of the present study may cover other similar cases in the Mediterranean, regarding in particular the specific aspect of the degree of openness towards the boaters coming from "continental" territories.

  1. COMPETITION BETWEEN CONTAINER PORTS IN THE NORTHERN ADRIATIC

    OpenAIRE

    Elen Twrdy; Milan Batista

    2014-01-01

    World trade has changed in the last decade such that container traffic flows are oriented towards more parts of the European continent. The European container port system is not a homogeneous set of ports; instead it consists of several big ports (e.g., Rotterdam, Hamburg, Algeciras...) and a large number of medium and small ports. Northern Adriatic (NA) ports, namely Rijeka, Koper, Trieste, Venice and Ravenna, are small ports. Each of these ports have different development plans but in varyi...

  2. The Challenges of Malaysian Dry Ports Development

    Directory of Open Access Journals (Sweden)

    Jagan Jeevan

    2015-03-01

    Full Text Available This paper examines the functions and challenges of dry ports development in Malaysia through 11 face-to-face interviews with dry port stakeholders. The findings reveal that Malaysian dry ports are developed to accelerate national and international business, to activate intermodalism in the nation, to promote regional economic development and to enhance seaport competitiveness. Malaysian dry ports perform the function of transport and logistics, information processing, seaports and value-added services. Challenges facing Malaysian dry ports include insufficient railway tracks, unorganized container planning on the rail deck, highly dependent on single mode of transportation, poor recognition from the seaport community, and competition from localized seaports. This paper further indicates strategies for coping with these challenges and identifies future opportunities for Malaysian dry ports development.

  3. Mitigation diagnostics

    International Nuclear Information System (INIS)

    Hall, S.T.

    1990-01-01

    This paper reports that experience in the remediation of schools and other large buildings has shown the importance of the effects of both the location of geologic sources and HVAC-induced distribution of indoor radon. In general, elevated radon in areas of schools with evenly distributed HVAC pressures are correlated with maximum soil radon emanations. However, strong or unequal HVAC effects can redistribute indoor radon to areas away from the direct source. Effective remediation required a complete understanding of both contributions. In some schools, highest indoor radon levels were located near large return ducts and were attributed to proximity to negative HVAC pressure. Successful sub-slab depressurization systems were installed, however, in rooms with lower indoor but greatest sub-slab radon levels, closest to the source. This shows the inadequacy of using indoor radon levels alone as a basis for remediation. Wings of two other schools with radon problems have equivalent window fan coil units in rooms of equal size and no central HVAC system. Highest indoor radon levels correlated well with highest sub-slab radon levels due to the equivalent effects of the window units. Diagnostic tests in other schools have revealed: blockwall radon transport to upper floors; high blockwall radon adjacent to sub-slab sources; and elevated indoor radon over crawlspace being drawn upward by HVAC-induced negative pressure, determined from indoor to outdoor micromanometer measurements

  4. Port pricing : principles, structure and models

    OpenAIRE

    Meersman, Hilde; Strandenes, Siri Pettersen; Van de Voorde, Eddy

    2014-01-01

    Price level and price transparency are input to shippers’ choice of supply chain and transport mode. In this paper, we analyse current port pricing structures in the light of the pricing literature and consider opportunities for improvement. We present a detailed overview of pricing criteria, who sets prices and who ultimately foots the bill for port-of-call charges, cargo-handling fees and congestion charges. Current port pricing practice is based on a rather linear structure and fails to in...

  5. Efficiency analysis of container ports and terminals

    OpenAIRE

    Liu, Q.

    2010-01-01

    In the past two decades the steady growth of seaborne trade has resulted in the increase of container ships, container ports and their terminals. The structure of the shipping market is, moreover, continuously evolving. On the carrier side, shipping companies form consortia and alliances; on the port side, global terminal operators and dedicated container terminals are emerging. The aim of this research is to evaluate the efficiency of container ports and terminals and to study...

  6. Port Sunlight, essai architectural et social

    OpenAIRE

    Machet, Laurence

    2017-01-01

    The purpose of this article is to examine the city of Port Sunlight, its history, design and originality. Created by William Lever in 1888 in order to house his newly-built soap factory, Port Sunlight is part of the numerous “factory villages” built in the wake of the industrial revolution according to philanthropic and utilitarian principles. But this article intends to show that Port Sunlight differs from other factory towns. Its careful design, elaborate architecture and public facilities ...

  7. PORT SECURITY-Threats and Vulnerabilities

    OpenAIRE

    Kusi, Bernard

    2015-01-01

    The main objective of this thesis is to identify the threats and the vulnerabilities concerning Takoradi port, and finally recommend measure to overcome the identified threats and vul-nerabilities. Various categories of potential threats and vulnerabilities have been studied throughout the literature review. However, because each port presents a unique sets of threats and vulnerabilities, there was a need to look critically into how Takoradi port operations are being conducted in other to ide...

  8. Maximizing port and transportation system productivity by exploring alternative port operation strategies.

    Science.gov (United States)

    2011-06-01

    Seaports are a critical transportation component that supports the nations economy. Many U.S. : ports are now experiencing significant truck congestion at the gate, which decreases the productivity of : ports and truck fleets (e.g. truck wait time...

  9. US Army Corps of Engineers Ports, Geographic WGS84, BTS (2006) [usace_port_BTS_2006

    Data.gov (United States)

    Louisiana Geographic Information Center — Contains physical information on commercial facilities at the principal U.S. Coastal, Great Lakes and Inland Ports. The data consists of listings of port area's...

  10. THE Port - hackathon at CERN

    CERN Multimedia

    CERN. Geneva; KNAEPPER, Ines; SILVA DE SOUSA, Bruno

    2014-01-01

    THE Port association combines creative minds from CERN and non-profit organisations in interdisciplinary teams to work on humanitarian technology related benefits to society. Our interdisciplinary teams of handpicked individuals chosen for their field-leading expertise and innovative mind combine humanitarian questions with state of the art science, cutting-edge technology and endless fantasy. We aim to impact the future by fusion of today’s real life problems analysis and vision of scientific evolution of the next decades. This forces us to develop concepts and solutions for the future - hungry to use our expertise in challenges of new fields.

  11. Port virtual addressing for PC

    International Nuclear Information System (INIS)

    Bolanos, L.; Arista, E.; Osorio Deliz, J.F.

    1997-01-01

    Instruments for nuclear signal measurements based on add-on card for a personal computer (PC) are designed often. Then one faces the problem of the addressing of data input/output devices which show an integration level or intelligence that makes the use of several port address indispensable, and these are limited in the PC. The virtual addressing offers the advantage of the occupation of few addresses to accede to many of these devices. The principles of this technique and the appliances of a solution in radiometric in a radiometric card based on programmed logic are discussed in this paper

  12. POLICY PORT IN LATIN AMERICA

    Directory of Open Access Journals (Sweden)

    María Victoria Flores

    2012-07-01

    Full Text Available This work achieves a contextual approach the port services market in Latin America, from the document review the legal framework and jurisprudence. It observes and evaluates the phenomenon under study, establishing a correlation between the grant in the shape of the free supply and demand for services and operating in a market of few suppliers, resulting in national legislation and concession contracts defending a free market and on the other hand, case law on market practice indicating that there is no free market to defend.

  13. Testing and Analysis of Sensor Ports

    Science.gov (United States)

    Zhang, M.; Frendi, A.; Thompson, W.; Casiano, M. J.

    2016-01-01

    This Technical Publication summarizes the work focused on the testing and analysis of sensor ports. The tasks under this contract were divided into three areas: (1) Development of an Analytical Model, (2) Conducting a Set of Experiments, and (3) Obtaining Computational Solutions. Results from the experiment using both short and long sensor ports were obtained using harmonic, random, and frequency sweep plane acoustic waves. An amplification factor of the pressure signal between the port inlet and the back of the port is obtained and compared to models. Comparisons of model and experimental results showed very good agreement.

  14. DEA Window Analysis for Measuring Port Efficiencies in Serbia

    Directory of Open Access Journals (Sweden)

    Danijela Pjevčević

    2012-01-01

    Full Text Available The aim of the paper is to apply Data Envelopment Analysis (DEA method in measuring and analyzing the efficiencies of ports on the river Danube. DEA window analysis is used to determine the efficiency of ports and to observe the possibility of changes in the port efficiency over time. A study is conducted to evaluate the efficiencies of ports on the territory of Serbia in order to identify the sources of inefficiencies and formulate proposals for improving the services of those ports and their operations through a four-year window analysis with port efficiency trends and average efficiencies. The progress is made in the measurement of port efficiency in relation to port productive activities - total area of warehouses, quay length, number of cranes and port throughput, for the Serbian river ports. Keywords: river ports, total area of warehouses, quay length, number of cranes, port throughput, port efficiency, DEA window analysis

  15. Perancangan Miniatur Traffic Light Dengan Mempergunakan Pengendali Port Paralel

    Directory of Open Access Journals (Sweden)

    Eka Wahyudi

    2012-05-01

    Full Text Available Port paralel tentunya sudah tidak asing lagi dalam dunia komputer. Hal tersebut disebabkan karena port paralel merupakan sarana komunikasi yang terdapat pada Personal Computer (PC. Dengan memanfaatkan port tersebut, saat ini komputer juga dapat dipergunakan untuk keperluan pengontrolan/pengendalian rangkaian listrik dengan memanfaatkan port paralel (port printer. Port paralel memiliki kecepatan transfer data yang lebih cepat apabila dibandingkan dengan port serial, maka dari itu port paralel lebih banyak dipergunakan untuk pengendalian nyala lampu (LED. Dengan memanfaatkan bantuan software Saraf Listrik versi 1.01, maka port paralel dapat menjadi alternatif baru untuk pengendalian traffic light.

  16. Non-Price Competition in the Port Sector: A Case Study of Ports in Turkey

    OpenAIRE

    Soner Esmer; Hong-Oanh Nguyen, Ph.D.; Yapa Mahinda Bandara, Ph.D.; Kazim Yeni, Ph.D.

    2016-01-01

    Although the port sector has been facing increasing competition, there is limited research on how ports compete using non-price competition strategies. There are a few studies on non-price competition in the port sector. However they mainly focus on the marketing aspect. This paper seeks to fill this gap in the literature, especially from a combined marketing-economic perspective. Especially the paper's main objective is to identify the determinants of non-price competition in the port sector...

  17. 19 CFR 101.3 - Customs service ports and ports of entry.

    Science.gov (United States)

    2010-04-01

    ... and Service Ports. Many of the ports listed were created by the President's message of March 3, 1913....S.C. 1). Subsequent orders of the President or of the Secretary of the Treasury which affected these... Port of the Delaware River and Bay described in T.D. 96-4. Perth Amboy New Mexico Albuquerque Including...

  18. DEMO port plug design and integration studies

    Science.gov (United States)

    Grossetti, G.; Boccaccini, L. V.; Cismondi, F.; Del Nevo, A.; Fischer, U.; Franke, T.; Granucci, G.; Hernández, F.; Mozzillo, R.; Strauß, D.; Tran, M. Q.; Vaccaro, A.; Villari, R.

    2017-11-01

    The EUROfusion Consortium established in 2014 and composed by European Fusion Laboratories, and in particular the Power Plant Physics and Technology department aims to develop a conceptual design for the Fusion DEMOnstration Power Plant, DEMO. With respect to present experimental machines and ITER, the main goals of DEMO are to produce electricity continuously for a period of about 2 h, with a net electrical power output of a few hundreds of MW, and to allow tritium self-sufficient breeding with an adequately high margin in order to guarantee its planned operational schedule, including all planned maintenance intervals. This will eliminate the need to import tritium fuel from external sources during operations. In order to achieve these goals, extensive engineering efforts as well as physics studies are required to develop a design that can ensure a high level of plant reliability and availability. In particular, interfaces between systems must be addressed at a very early phase of the project, in order to proceed consistently. In this paper we present a preliminary design and integration study, based on physics assessments for the EU DEMO1 Baseline 2015 with an aspect ratio of 3.1 and 18 toroidal field coils, for the DEMO port plugs. These aim to host systems like electron cyclotron heating launchers currently developed within the Work Package Heating and Current Drive that need an external radial access to the plasma and through in-vessel systems like the breeder blanket. A similar approach shown here could be in principle followed by other systems, e.g. other heating and current drive systems or diagnostics. The work addresses the interfaces between the port plug and the blanket considering the helium-cooled pebble bed and the water cooled lithium lead which are two of four breeding blanket concepts under investigation in Europe within the Power Plant Physics and Technology Programme: the required openings will be evaluated in terms of their impact onto the

  19. Development of ITER diagnostics: Neutronic analysis and radiation hardness

    Energy Technology Data Exchange (ETDEWEB)

    Vukolov, Konstantin, E-mail: vukolov_KY@nrcki.ru; Borisov, Andrey; Deryabina, Natalya; Orlovskiy, Ilya

    2015-10-15

    Highlights: • Problems of ITER diagnostics caused by neutron radiation from hot DT plasma considered. • Careful neutronic analysis is necessary for ITER diagnostics development. • Effective nuclear shielding for ITER diagnostics in the 11th equatorial port plug proposed. • Requirements for study of radiation hardness of diagnostic elements defined. • Results of optical glasses irradiation tests in a fission reactor given. - Abstract: The paper is dedicated to the problems of ITER diagnostics caused by effects of radiation from hot DT plasma. An effective nuclear shielding must be arranged in diagnostic port plugs to meet the nuclear safety requirements and to provide reliable operation of the diagnostics. This task can be solved with the help of neutronic analysis of the diagnostics environment within the port plugs at the design stage. Problems of neutronic calculations are demonstrated for the 11th equatorial port plug. The numerical simulation includes the calculations of neutron fluxes in the port-plug and in the interspace. Options for nuclear shielding, such as tungsten collimator, boron carbide and water moderators, stainless steel and lead screens are considered. Data on neutron fluxes along diagnostic labyrinths allow to define radiation hardness requirements for the diagnostic components and to specify their materials. Options for windows and lenses materials for optical diagnostics are described. The results of irradiation of flint and silica glasses in nuclear reactor have shown that silica KU-1 and KS-4V retain transparency in visible range after neutron fluence of 10{sup 17} cm{sup −2}. Flints required for achromatic objectives have much less radiation hardness about 5 × 10{sup 14} n/cm{sup 2}.

  20. Progress of the ECRH Upper Launcher design for ITER

    International Nuclear Information System (INIS)

    Strauss, D.; Aiello, G.; Bruschi, A.; Chavan, R.; Farina, D.; Figini, L.; Gagliardi, M.; Garcia, V.; Goodman, T.P.; Grossetti, G.; Heemskerk, C.; Henderson, M.A.; Kasparek, W.; Krause, A.; Landis, J.-D.; Meier, A.; Moro, A.; Platania, P.; Plaum, B.; Poli, E.

    2014-01-01

    The design of the ITER ECRH system provides 20 MW millimeter wave power for central plasma heating and MHD stabilization. The system consists of an array of 24 gyrotrons with power supplies coupled to a set of transmission lines guiding the beams to the four upper and the equatorial launcher. The front steering upper launcher design described herein has passed successfully the preliminary design review, and it is presently in the final design stage. The launcher consists of a millimeter wave system and steering mechanism with neutron shielding integrated into an upper port plug with the plasma facing blanket shield module (in-vessel) and a set of ex-vessel waveguides connecting the launcher to the transmission lines. Part of the transmission lines are the ultra-low loss CVD torus diamond windows and a shutter valve, a miter bend section and the feedthroughs integrated in the plug closure plate. These components are connected by corrugated waveguides and form together the first confinement system (FCS). In-vessel, the millimeter-wave system includes a quasi-optical beam propagation system including four mirror sets and a front steering mirror. The millimeter wave system is integrated into a specifically optimized upper port plug providing structural stability to withstand plasma disruption forces and the high heat load from the plasma side with a dedicated blanket shield module. A recent update in the ITER interface definition has resulted in the recession of the upper port plug first wall panels, which is now integrated into the design. Apart from the millimeter wave system the upper port plug houses also a set of shield blocks which provide neutron shielding. An overview of the actual ITER ECRH Upper Launcher is given together with some highlights of the design

  1. Porting Biomedical Applications to Grids

    NARCIS (Netherlands)

    T.A. Knoch (Tobias)

    2008-01-01

    textabstractToday advances in scientific research as well as clinical diagnostics and treatment are inevitably connected with information solutions concerning computation power and information storage. The needs for information technology are enormous and are in many cases the limiting

  2. Port-Orford-Cedar Root Disease

    Science.gov (United States)

    Lewis F. Roth; Robert D. Jr. Harvey; John T. Kliejunas

    1987-01-01

    The most serious disease of Port-Orford-cedar (Chamaecyparis lawsoniana (A. Murr.) Parl.) is a root disease caused by the fungus Phytophthora lateralis. Nursery stock, ornamentals, and timber trees are subject to attack. Other species of Chamaecyparis are less susceptible than Port-Orford-cedar, and trees of other genera are not affected.

  3. Are we connected? : Ports in Global Networks

    NARCIS (Netherlands)

    R.A. Zuidwijk (Rob)

    2015-01-01

    markdownabstractAbstract Global supply chains are built on organizational, information, and logistics networks. Ports are connected via these networks and also need to connect these networks. Synchromodality is an innovative concept for container transportation, and the port plays an important

  4. Lessons from Hurricane Sandy for port resilience.

    Science.gov (United States)

    2013-12-01

    New York Harbor was directly in the path of the most damaging part of Hurricane Sandy causing significant impact on many of the : facilities of the Port of New York and New Jersey. The U.S. Coast Guard closed the entire Port to all traffic before the...

  5. Visual Support for Porting Large Code Bases

    NARCIS (Netherlands)

    Broeksema, Bertjan; Telea, Alexandru

    2011-01-01

    We present a tool that helps C/C++ developers to estimate the effort and automate software porting. Our tool supports project leaders in planning a porting project by showing where a project must be changed, how many changes are needed, what kinds of changes are needed, and how these interact with

  6. Single port VATS: recent developments in Asia.

    Science.gov (United States)

    Yu, Peter S Y; Capili, Freddie; Ng, Calvin S H

    2016-03-01

    Single port video-assisted thoracic surgery (VATS) is the most recent evolution in minimally invasive thoracic surgery. With increasing global popularity, the single port VATS approach has been adopted by experienced thoracic surgeons in many Asian countries. From initial experience of single port VATS lobectomy to the more complex sleeve resection procedures now forming part of daily practice in some Asia institutes, the region has been the proving ground for single port VATS approaches' feasibility and safety. In addition, certain technical refinements in single port VATS lung resection and lymph node dissection have also sprung from Asia. Novel equipment designed to facilitate single port VATS allowing further reduce access trauma are being realized by the partnership between surgeons and the industries. Advanced thoracoscopes and staplers that are narrower and more maneuverable are particularly important in the smaller habitus of patients from Asia. These and similar new generation equipment are being applied to single port VATS in novel ways. As dedicated thoracic surgeons in the region continue to striving for excellence, innovative ideas in single incision access including subxiphoid and embryonic natural-orifice transluminal endoscopic surgery (e-NOTES) have been explored. Adjunct techniques and technology used in association with single port VATS such as non-intubated surgery, hybrid operating room image guidance and electromagnetic navigational bronchoscopy are all in rapid development in Asia.

  7. Cyber security in ports : Business as usual

    NARCIS (Netherlands)

    Moerel, Lokke; Dezeure, Freddy

    2017-01-01

    Our paper summarizes the risks and provides concrete and pragmatic proposals to increase substantially the cyber maturity and resilience in the ports by organizing training and awareness raising, fostering cooperation and information exchange both between the stakeholders in the ports and across the

  8. On Distributed Port-Hamiltonian Process Systems

    NARCIS (Netherlands)

    Lopezlena, Ricardo; Scherpen, Jacquelien M.A.

    2004-01-01

    In this paper we use the term distributed port-Hamiltonian Process Systems (DPHPS) to refer to the result of merging the theory of distributed Port-Hamiltonian systems (DPHS) with the theory of process systems (PS). Such concept is useful for combining the systematic interconnection of PHS with the

  9. Rotterdam as a World Port City

    NARCIS (Netherlands)

    Wouter Jacobs; Menno Huijs; Isabelle Vries

    2015-01-01

    Most studies and models on the port-city interface focus on the inevitable process in which ports and cities grow apart, both spatially and economically. What is often overlooked is the relationships that remain in the form of maritime business services (finance, insurance, legal). These maritime

  10. Working with Nature in Wadden Sea Ports

    NARCIS (Netherlands)

    Baptist, M.J.; Eekelen, van E.; Dankers, P.J.T.; Grasmeijer, B.; Kessel, van T.; Maren, van D.S.

    2017-01-01

    Wadden Sea ports are situated at the border of the UNESCO World Heritage site Wadden Sea. Because of the protected status of this area, developing new economic activities is not straightforward. However, maintaining and developing port activities is needed to safeguard the economic viability of the

  11. Dry Port Development: A Systematic Review

    Directory of Open Access Journals (Sweden)

    Fatimazahra BENTALEB

    2015-12-01

    Full Text Available Studies on dry ports as nodes in multimodal transport have been expanded to decrease the mounting congestion on seaports. The principal objective of this study is to inspect how dry port researches have been conducted from different perspective. This paper tries to recap the existing researches that aimed to study dry port concept via a systematic review, to present a general overview of the researches on our relevant region and propose a classification for these researches. This paper present a systematic review of dry port that looks to illustrate the progress of researches on this area between 1986 and 2015, collecting researches on dry port concept and analyzing the main characteristics of the dry port development and their contribution to the multimodal transport. The results indicated that most dry port studies considerate the strategic level and concentrate in the Asian continent. Studies regarding other decision levels and continents have to be developed in further researches. Although the existing studies make a contribution in dry port concept, they allow gaps in terms of operational and tactical decision levels considering their limited geographical region.

  12. Laser treatment of Port-wine stains

    OpenAIRE

    Boffa, Michael J.

    2001-01-01

    A state-of-the-art pulsed dye laser machine to treat port-wine stains and other vascular lesions has been available in the Malta Health Service since 1999. This article reviews the pathophysiology and clinical features of port- wine stains and describes the principles of laser treatment for this condition.

  13. Ports Primer: 3.3 Federal and International Governance

    Science.gov (United States)

    State and local governments are important players in port governance and in oversight of transportation projects that may affect ports. Private corporations may also play a role if they lease or own a terminal at a port.

  14. in upper gastrointestinal endoscopy

    Directory of Open Access Journals (Sweden)

    Sinan Uzman

    2016-07-01

    Full Text Available Introduction : There is increasing interest in sedation for upper gastrointestinal endoscopy (UGE. Prospective randomized studies comparing sedation properties and complications of propofol and midazolam/meperidine in upper gastrointestinal endoscopy (UGE are few. Aim: To compare propofol and midazolam/meperidine sedation for UGE in terms of cardiopulmonary side effects, patient and endoscopist satisfaction and procedure-related times. Material and methods: This was a prospective, randomized, double-blind study of propofol versus midazolam and meperidine in 100 patients scheduled for diagnostic upper gastrointestinal endoscopy. The patients were divided into propofol and midazolam/meperidine groups. Randomization was generated by a computer. Cardiopulmonary side effects (hypotension, bradycardia, hypoxemia, procedure-related times (endoscopy time, awake time, time to hospital discharge, and patient and endoscopist satisfaction were compared between groups. Results: There was no significant difference between the groups with respect to the cost, endoscopy time, or demographic and clinical characteristics of the patients. Awake time and time to hospital discharge were significantly shorter in the propofol group (6.58 ±4.72 vs. 9.32 ±4.26 min, p = 0.030 and 27.60 ±7.88 vs. 32.00 ±10.54 min, p = 0.019. Hypotension incidence was significantly higher in the propofol group (12% vs. 0%, p = 0.027. The patient and endoscopist satisfaction was better with propofol. Conclusions : Propofol may be preferred to midazolam/meperidine sedation, with a shorter awake and hospital discharge time and better patient and endoscopist satisfaction. However, hypotension risk should be considered with propofol, and careful evaluation is needed, particularly in cardiopulmonary disorders.

  15. Two-port access versus four-port access laparoscopic ovarian cystectomy.

    Science.gov (United States)

    Choi, Won-Kyu; Kim, Jang-Kew; Yang, Jung-Bo; Ko, Young-Bok; Nam, Sang-Lyun; Lee, Ki-Hwan

    2014-09-01

    This study was conducted to compare the surgical outcomes between two-port access and four-port access laparoscopic ovarian cystectomy. Four hundred and eighty nine patients who had received two-port access laparoscopic ovarian cystectomy (n=175) and four-port access laparoscopic ovarian cystectomy (n=314) in Chungnam National University Hospital from January 2009 to August 2012 were analyzed retrospectively. The data were compared between the bilaterality of the cysts and cyst diameter of less than 6 cm and 6 cm or more. There were no significant differences in patient's age, parity, body weight, body mass index and history of previous surgery between the two-port and four-port access laparoscopy group. Bilaterality of ovarian cysts was more in fourport access laparoscopy group (13.7% vs. 32.5%, P=0.000). There were no significant differences in operation time, hemoglobin change, hospital stay, adhesiolysis, transfusion, and insertion of hemo-vac between the two-port and four-port access laparoscopy group for size matched compare. However additional analgesics were more in four-port access laparoscopy group for unilateral ovarian cystectomy. Two-port access laparoscopic surgery was feasible and safe for unilateral and bilateral ovarian cystectomy compare with four-port access laparoscopic surgery.

  16. Influence of Port Policy on the Development of Croatian Container Ports

    Directory of Open Access Journals (Sweden)

    Čedomir Dundović

    2002-03-01

    Full Text Available It is important to consider the port development throughoutthe world from the aspect of economical, transport and portpolicy and their mutual impact on commerce and efficiency ofports. By examining such relations in the context of developmentof the Croatian container ports, it is possible to define reasonsfor lagging behind of Croatian ports compared to theworld movements.The main reason for the negative trend of development ofCroatian container ports lies in the non-existence of adequatemeasures of transport, maritime and port policy. Analysis ofstatistics over the past decade and comparison of structure andvolume of the general cargo traffic in the Rijeka port and theneighbouring ports in the area of North Adriatic are both showingsignificant size discrepancy and uncompetitiveness of theCroatian port. Disturbances that have brought to such a situationresult from inadequate port policy and non-harmonisedactivities between various modes of transport.In order to overcome such situation, the authors suggest determiningof clear tasks, goals and measures of the port policythat have to be undertaken so that the Croatian policy could becompatible with the main aspects, development tendencies andmeasures of theE U port policy.

  17. Colonial Origins of the Port of Buenaventura

    Directory of Open Access Journals (Sweden)

    Alonso Valencia Llano

    2014-07-01

    Full Text Available This article studies the origins of the Port of Buenaventura in the New Kingdom of Granada. It begins with the process of exploration of the coastal territory in order to highlight the different sites in which it was situated, demonstrating that it began as a river port and was later resituated and gradually converted into a maritime port. In addition, this article analyzes the problems it faced, such as the dificulty of communication with the interior of the country, the indigenous resistance that caused the destruction of the town, and inally the necessity of populating the zone with black slaves in order to exploit the mining border. This study also discusses how this port was controlled by the elite of the city of Cali, until the Republican period when it became the sole Colombian port on the Paciic Ocean.

  18. Integrated circuit test-port architecture and method and apparatus of test-port generation

    Science.gov (United States)

    Teifel, John

    2016-04-12

    A method and apparatus are provided for generating RTL code for a test-port interface of an integrated circuit. In an embodiment, a test-port table is provided as input data. A computer automatically parses the test-port table into data structures and analyzes it to determine input, output, local, and output-enable port names. The computer generates address-detect and test-enable logic constructed from combinational functions. The computer generates one-hot multiplexer logic for at least some of the output ports. The one-hot multiplexer logic for each port is generated so as to enable the port to toggle between data signals and test signals. The computer then completes the generation of the RTL code.

  19. Dual-port distal gastrectomy for the early gastric cancer

    OpenAIRE

    Kashiwagi, Hiroyuki; Kumagai, Kenta; Monma, Eiji; Nozue, Mutsumi

    2014-01-01

    Background Although recent trends in laparoscopic procedures have been toward minimizing the number of incisions, four or five ports are normally required to complete laparoscopic gastrectomy because of the complexity of this procedure. Multi-channel ports, such as the SILS port (Covidien, JAPAN), are now available and are crucial for performing single-incision laparoscopic surgery (SILS) or reduced port surgery (RPS). We carried out reduced port distal gastrectomy (RPDG) using a dual-port me...

  20. E-Commerce in Ports

    Directory of Open Access Journals (Sweden)

    Elen Twrdy

    2002-01-01

    Full Text Available EDI (Electronic Data Interchange and electronic businessshould be looked upon as a natural evolution in the internationaltrade and transport cycle. One of the principal reasonsfor starting to use EDI are the heaps of documents written,shifted, handled, conected, transcribed and copied for normalbusiness and administrative transactions. EDJ and in generalelectronic business would have none of the disadvantages ofpaper documents and have already brought substantial benefitsand savings to companies that implement it.Most port community systems today still do not provide forelectronic transfer of funds or for electronic interchange of invoicesand other trade documents, for instance bills of lading.Such services are specific toe-business and they are the necessarytransport-related documents.

  1. The Practice of Guangzhou Port Planning Environmental Impact Assessment

    Science.gov (United States)

    Wang, Ning; Zhao, Junjie; Shou, Youping; Qiao, Jianzhe; Dong, Shipei; Zhang, Lu

    2018-01-01

    In this paper, the effects of the implementation of Guangzhou port plan were analyzed from hydrological condition, water environment and ecological environment. Regional water environmental carrying capacity was analyzed. Guangzhou port is a main port in the coast of China, it is an important port of foreign trade in south China, it is an important port for energy supplies and raw materials in Guangdong province [1]. With the shipping channel condition improvement and the construction of large specialized container port area, Guangzhou port will gradually become trunk line port of container transport in south China.

  2. Šport in humanistika

    Directory of Open Access Journals (Sweden)

    Jože Vogrinc

    2012-07-01

    Full Text Available O tem, ali je šport »neresen« pojav ali pojav, ki razkriva bistvene razsežnosti tistega, za kar človeku gre, se pogledi razhajajo. Glede na to, da so humanistične študije športa vsaj na prvi pogled nekje na obrobju ved, ki jih združuje Filozofska fakulteta, bi morda veljalo, da ga ne moremo primerjati z globoko resnimi temami, zlasti pa ne z najnovejšimi resnimi zahtevami, ki jih družba postavlja univerzi in znanostim: pripomoči k višji donosnosti in poslovnosti podjetništva ter ohranjati tradicijo in krepiti življenjsko moč naroda. Pa se že pri tem izkaže, da športa ne gre preveč zapostavljati; po eni strani je že nekaj desetletij, kar je postal izjemno kapitalsko zanimivo in donosno področje, v katero podjetniki bodisi vlagajo, da bi dosegali dobičke, bodisi ga podpirajo, da bi z njegovo pomočjo svoje blago povzdignili v simbol pravilno naravnanega načina življenja; po drugi strani pa je tradicija nacionalne pomembnosti vrhunskih športnih izidov in dosežkov le nekaj krajša od drugih načinov mednarodnega uveljavljanja naroda, pomen športnih dosežkov za dokazovanje življenjske moči naroda pa se lahko kosa s pomenom lestvic, kakršne izdajajo mednarodne finančne ustanove o državah, ali lestvic, na katerih najdemo univerze, razvrščene po njihovi pedagoški in znanstveni moči. Pomembnost športa pa podčrtavajo tudi tisti, ki ga ostro kritizirajo in njegovo sodobno vrhunsko različico odklanjajo kot obliko alienacije, manipulacije in ideologije, saj prav športni spektakularizaciji pripisujejo najvišjo napetost, največji pomen in najotipljivejšo moč nad ljudmi, ki bi se morali bojevati za spremembo svojega družbenega položaja in prevrat v vsej družbeni strukturi, pa jih razvedrila, med katerimi ima šport posebej visoko mesto, uspavajo in pomirjajo prav s tem, da njihovo napetost sproščajo v nenevaren odliv socialne energije. Tega kritičnega vidika sodobnega športa ne kaže omejiti zgolj na vrhunski

  3. Surface CUrrents from a Diagnostic model (SCUD): Pacific

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The SCUD data product is an estimate of upper-ocean velocities computed from a diagnostic model (Surface CUrrents from a Diagnostic model). This model makes daily...

  4. ITER diagnostics: Design choices and solutions

    International Nuclear Information System (INIS)

    Costley, A.E.; Sugie, T.; Vayakis, G.; Malaquias, A.; Walker, C.

    2003-01-01

    An extensive diagnostic system will be installed on ITER to provide the measurements necessary to control, evaluate and optimise the plasma performance and to study burning plasma physics. Because of the harsh environment, diagnostic system selection and design has to cope with a range of phenomena not previously encountered in diagnostic implementation. In this paper, we describe the key problems encountered and give examples of the solutions that have been developed. A brief description of the scheme developed for integrating multiple systems into individual ports is also included. We conclude with an assessment of overall system performance. (author)

  5. DIM and diagnostic placement for NIF experiments

    International Nuclear Information System (INIS)

    Kalantar, D.

    1999-01-01

    The input that has been provided on the NIF experiment setup sheets has allowed us to review the diagnostic and DIM placement as well as the baseline unconverted light management plan. We have done an iteration to identify common diagnostic lines of sight, and with additional requirements defined by specific experiments, we propose (1) a baseline plan for DIM placement requiring only five DIMs that may be moved between up to seven DIM ports, and (2) a modified baseline unconverted light management plan. We request additional input to identify primary vs. secondary diagnostics for each experiment definition

  6. TRENDS IN CONTEMPORARY PORT SERVICES MARKETS

    Directory of Open Access Journals (Sweden)

    Hanna Klimek

    2014-12-01

    Full Text Available This article describes the issues associated with functioning of contemporary seaport services markets. The growth of international supply chains, technical progress and the integration processes in shipping, growth of containerization, increasing competition in the seaport services markets and environmental protection regulations make it necessary for port service providers to adapt to the changing expectations and requirements of their customers, both shippers and, especially maritime, carriers. Thus, the activities they undertake are associated with making investments to ensure an adequate capacity to handle cargo, passengers and means of transport, required quality of service, but also with appropriate organization of port supply centres and lead to an improvement of their competitiveness. Both the factors associated with the external and internal environment of seaports affect the changes in the relationship between the supply and demand on port services markets. Contemporary port services markets are characterized by certain phenomena which can be a sign of their adaptation and development. The aim of this article is to present the essence of the port services market and its relationship with the environment, which subject to rapid and significant changes, creates new conditions for the operation of port supply centres and the entire port services market.

  7. Towards Sustainable ASEAN Port Development: Challenges and Opportunities for Vietnamese Ports

    Directory of Open Access Journals (Sweden)

    Saeyeon Roh

    2016-06-01

    Full Text Available Sustainability agendas are challenging port authorities around the world to find ways of operating and managing their ports efficiently and effectively in terms of economic, social, as well as environmental development. In this respect, governments in ASEAN countries have been implementing various green activities seeking to reduce the environmental impact of shipping and related activities. In this connection, most studies in the existing literature mainly focus on the environmental aspects of sustainable development and have not clearly explained what sustainable port development exactly entails. Furthermore, most of these studies emphasized on the impact of port development and overlooked what factors influence sustainable port development. To address these gaps, this research aim to explore the main factors shaping sustainable port development. This was conducted through a comprehensive review of related literature as well as confirmatory in-depth interviews with port authorities. As a result, findings from this research would help identify key elements of sustainable port development from port authorities’ perspective. The challenges, opportunities and managerial implications for Vietnamese ports are also discussed accordingly.

  8. [Cytology in uropathological diagnostics].

    Science.gov (United States)

    Gaisa, N T; Lindemann-Docter, K

    2015-11-01

    Cytology in uropathological diagnostics is mainly performed for oncological purposes. The assessment of malignancy by urothelial cell morphology is therefore decisive; however, cytology is only sensitive enough to detect high-grade tumor cells and the different low-grade tumors cannot be reliably diagnosed. Thus, the four-tier classification system of cytological findings (i.e. negative, atypical cells but significance uncertain, suspicious and positive) refers to high-grade tumor cells only. Furthermore, for valid cytological diagnostics not only the cytological specimen but also clinical information on cystoscopy findings and, if applicable, a biopsy should be evaluated together. In difficult differential diagnostic settings, e.g. differentiation between reactive versus neoplastic atypia or difficult to access lesions in the upper urinary tract, additional fluorescence in situ hybridization of cytological preparations might be helpful. At the moment there are no indications for further immunocytology or additional biomarker tests.

  9. Long-term Outcome of Peripherally Implanted Venous Access Ports in the Forearm in Female Cancer Patients

    Energy Technology Data Exchange (ETDEWEB)

    Klösges, Laura, E-mail: l.kloesges@uni-bonn.de; Meyer, Carsten, E-mail: carsten.meyer@ukb.uni-bonn.de; Boschewitz, Jack, E-mail: jack.boschewitz@ukb.uni-bonn.de; Andersson, Magnus, E-mail: magnus.andersson@ukb.uni-bonn.de [Universitätsklinikum Bonn, Department of Radiology (Germany); Rudlowski, Christian, E-mail: c.rudlowski@evk.de [Evangelisches Krankenhaus Bergisch Gladbach, Department of Gynecology (Germany); Schild, Hans H., E-mail: hans.schild@ukb.uni-bonn.de [Universitätsklinikum Bonn, Department of Radiology (Germany); Wilhelm, Kai, E-mail: kai.wilhelm@ek-bonn.de [Ev. Kliniken Bonn, Johanniter-Krankenhaus, Department of Radiology (Germany)

    2015-06-15

    PurposeThe aim of this retrospective study was to analyze the long-term outcome of peripherally implanted venous access ports in the forearm at our institution in a female patient collective.MethodsBetween June 2002 and May 2011, a total of 293 female patients with an underlying malignancy had 299 forearm ports implanted in our interventional radiology suite. The mean age of the cohort was 55 ± 12 years (range 26–81 years). The majority of women suffered from breast (59.5 %) or ovarian cancer (28.1 %). Complications were classified as infectious complications, thrombotic and nonthrombotic catheter dysfunction (dislocation of the catheter or port chamber, fracture with/without embolization or kinking of the catheter, port occlusion), and others.ResultsWe analyzed a total of 90,276 catheter days in 248 port systems (47 patients were lost to follow-up). The mean device service interval was 364 days per catheter (range 8–2,132, median 223 days, CI 311–415, SD 404). Sixty-seven early (≤30 days from implantation) or late complications (>30 days) occurred during the observation period (0.74/1,000 catheter days). Common complications were port infection (0.18/1,000 days), thrombotic dysfunction (0.12/1,000 days), and skin dehiscence (0.12/1,000 days). Nonthrombotic dysfunction occurred in a total of 21 cases (0.23/1,000 days) and seemed to cumulate on the venous catheter entry site on the distal upper arm.ConclusionPeripherally implanted venous access ports in the forearm are a safe alternative to chest or upper-arm ports in female oncology patients. Special attention should be paid to signs of skin dehiscence and nonthrombotic dysfunction, especially when used for long-term treatment.

  10. Potential risk of port-site adhesions in patients after laparoscopic myomectomy using radially expanding trocars.

    Science.gov (United States)

    Kumakiri, Jun; Kikuchi, Iwaho; Kitade, Mari; Jinushi, Makoto; Shinjyo, Azusa; Takeda, Satoru

    2015-01-01

    To investigate the incidence of port-site adhesions following use of radially expanding trocars (RETs) at laparoscopic myomectomy by observation via second-look laparoscopy (SLL). In a retrospective study, data from patients who underwent SLL after laparoscopic myomectomy between January 2007 and June 2012 at Juntendo University Hospital, Tokyo, were assessed for the incidence of port-site adhesions forming below RET incisional scars when fascial and peritoneal defects had not been closed. During the study period, 554 patients underwent SLL, and 2176 incisional scars were examined. Adhesions were detected in 15 patients (2.8%); thus, the incidence of port-site adhesions under scars was 0.7% (15/2176). Among these 15 patients, the wounds with adhesions were located as follows: 6 (1.1%) under the umbilical scar, 5 (0.9%) under the right lower abdominal scar, 2 (0.4%) under the left upper abdominal scar, and 2 (0.4%) under the left lower abdominal scar. According to multiple regression analysis, the duration of laparoscopic myomectomy was positively associated with port-site adhesions (odds ratio, 1.79; 95% confidence interval, 1.09-2.94; P=0.02). The present data suggest that the incidence of port-site hernias and adhesions under RET incisional scars is low despite the non-closure of fascial and peritoneal defects. Copyright © 2014 International Federation of Gynecology and Obstetrics. Published by Elsevier Ireland Ltd. All rights reserved.

  11. Shut-down dose rate analyses for the ITER electron cyclotron-heating upper launcher

    Energy Technology Data Exchange (ETDEWEB)

    Weinhorst, Bastian; Serikov, Arkady; Fischer, Ulrich; Lu, Lei [Institute for Neutron Physics and Reactor Technology INR (Germany); Karlsruhe Institute of Technology KIT (Germany); Spaeh, Peter; Strauss, Dirk [Institute for Applied Materials IAM (Germany); Karlsruhe Institute of Technology KIT (Germany)

    2014-10-15

    The electron cyclotron resonance heating upper launcher (ECHUL) is going to be installed in the upper port of the ITER tokamak thermonuclear fusion reactor for plasma mode stabilization (neoclassical tearing modes and the sawtooth instability). The paper reports the latest neutronic modeling and analyses which have been performed for the ITER reference front steering launcher design. It focuses on the port accessibility after reactor shut-down for which dose rate (SDDR) distributions on a fine regular mesh grid were calculated. The results are compared to those obtained for the ITER Dummy Upper Port. The calculations showed that the heterogeneous ECHUL design gives rise to enhanced radiation streaming as compared to the homogenous dummy upper port. Therefore the used launcher geometry was upgraded to a more recent development stage. The inter-comparison shows a significant improvement of the launchers shielding properties but also the necessity to further upgrade the shielding performance. Furthermore, the analysis for the homogenous dummy upper port, which represents optimal shielding inside the launcher, demonstrates that the shielding upgrade also needs to include the launcher's environment.

  12. Intraluminal erosion of laparoscopic gastric band tubing into duodenum with recurrent port-site infections.

    Science.gov (United States)

    Cintolo, Jessica A; Levine, Marc S; Huang, Stephanie; Dumon, Kristoffel

    2012-01-01

    Intraluminal erosion of a laparoscopic gastric band into the stomach has been reported as a complication of laparoscopic adjustable gastric banding. To our knowledge, however, intraluminal erosion of the band tubing into the duodenum has not been described. We report a 46-year-old man in whom a laparoscopic adjustable gastric band tubing eroded into the duodenal lumen, causing recurrent port-site infections. This complication was diagnosed on upper endoscopy and also, in retrospect, on an upper gastrointestinal barium study and computed tomography. The patient underwent surgical removal of the band and tubing, with a primary duodenal repair, and made a complete recovery without complications. Erosion of laparoscopic band tubing into the duodenum should be included in the differential diagnosis for recurrent port-site infections after laparoscopic adjustable gastric banding. Radiographic or endoscopic visualization of the intraluminal portion of the tubing may be required for confirmation. Definitive treatment of this complication entails surgical removal of the tubing from the duodenum.

  13. Enabling information sharing in a port

    DEFF Research Database (Denmark)

    Olesen, Peter Bjerg; Hvolby, Hans-Henrik; Dukovska-Popovska, Iskra

    2012-01-01

    Ports are integral parts of many supply chains and are as such a contributing factor to the overall efficiency of the supply chain. Ports are also dynamic entities where things changes continuously. The dynamic nature of ports is also a problem when trying to optimise the utilisation of resources...... and ensure a low lead-time. Information sharing is a very important tool to reduce the effect of dynamism. This paper attempts to explain how information sharing is enabled in such an environment, and which considerations are relevant, both in regards to the information and required technology. The paper...

  14. Assesment of port governance in Brazil: a managerial perspective on the port of Santos

    OpenAIRE

    Almeida, José Eduardo Costa de

    2015-01-01

    The role of maritime transportation within international trade was drastically revamped during the inception of the globalization process, which enhanced the contribution of ports in world economy as main logistics gateways for global production and trade. As a result, the relationship between ports and governments has changed. Devolution ideologies that had been applied in other industries decades ago were now being considered by governments for the port industry. Many central governments so...

  15. Algorithms for Port-of-Entry Inspection

    National Research Council Canada - National Science Library

    Roberts, Fred S

    2007-01-01

    .... The percentage at some ports has now risen to 6%, but this is still a very small percentage. The purpose of this project was to develop decision support algorithms that help to optimally intercept illicit materials and weapons...

  16. Port: arstid kasutavad narkootikume / Marina Lohk

    Index Scriptorium Estoniae

    Lohk, Marina

    2015-01-01

    Tallinna ülikooli terviseteaduste ja spordi instituudi direktor ja spordibioloog Kristjan Port mainis ETV saates "Vabariigi kodanikud", et töövõime taastamiseks kasutatakse sageli narkootilisi aineid ning seda teevad ka arstid. Kristjan Porti selgitused

  17. Port Authority of Allegheny County Transit Stops

    Data.gov (United States)

    Allegheny County / City of Pittsburgh / Western PA Regional Data Center — All transit stops within the Port Authority of Allegheny County's service area for the November 20, 2016 - March (TBD) 2017 schedule period.

  18. Grain operator miffed at port administration

    Index Scriptorium Estoniae

    2006-01-01

    Ventspils Grain Terminal saatis president Vaira Vike-Freibergale ja mitmetele ministritele kirja sõnumiga, et Ventspilsi Vabasadama (Ventspils Free Port) administratsiooni tegevus takistab terminali äritegevust

  19. Tamralipti: The ancient port of India

    Digital Repository Service at National Institute of Oceanography (India)

    Tripati, S.; Rao, S.R.

    20', 87 degrees 55') east coast of India. Other ports of Bengal, such as Satgaon and Sonargaon were also having overseas contacts with Ceylone, Java and Sumatra. In this paper, an attempt is made to synthesize archaeological, literary, epigraphic...

  20. Public Port Finance Survey for FY 2006

    Science.gov (United States)

    2008-12-01

    This report is the result of a cooperative effort between the Maritime Administration and : the American Association of Port Authorities (AAPA). It was prepared by the Maritime : Administration, using financial information furnished by AAPA. : This i...

  1. Variable Delay in port-Hamiltonian Telemanipulation

    NARCIS (Netherlands)

    Secchi, C; Stramigioli, Stefano; Fantuzzi, C.

    2006-01-01

    In several applications involving bilateral telemanipulation, master and slave act at different power scales. In this paper a strategy for passively dealing with variable communication delay in scaled port-Hamiltonian based telemanipulation over packet switched networks is proposed.

  2. An Analysis of Port Service Quality and Customer Satisfaction: The Case of Korean Container Ports

    Directory of Open Access Journals (Sweden)

    Gi Tae Yeo

    2015-12-01

    Full Text Available Ports play a critical role in the economy of many countries and regions. Failure or unreliability of port services can significantly influence port customers—shipping lines and cargo owners—and result in their dissatisfaction. However, what constitutes port service quality (PSQ and its influence on the satisfaction of port customers has not been well investigated in the literature. Therefore, this study investigates the concept of PSQ and its influence on customer satisfaction in the case of Korean container ports. Following a literature review, a conceptual model of PSQ and its influence on customer satisfaction is proposed. The model was validated through a survey of 313 members of the Korean Port Logistics Association (KPLA. Partial least squares structural equation modeling (PLS-SEM was conducted to confirm the PSQ dimensions and to examine their relationship with customer satisfaction using SmartPLS 3.2.1 software. PSQ is found to be a five-factor construct, and its management, and image and social responsibility factors have significant positive effects on customer satisfaction. In addition to its academic contribution, this study also contributes to management practices because port managers can use the PSQ scale to measure their customers’ satisfaction and justify investments in the quality management of port services.

  3. Managing Risks in Dry Port Operations

    OpenAIRE

    Ciortescu Cezar-Gabriel; Pãvãla?cu Narcis Sebastian

    2012-01-01

    The purpose of this paper is to have an in-depth look into the phenomenon of risk assessment and risk management strategies in managing dry port operations as an integrated part into international containerized freight trade. The fact that world crises take the form of disruptions, bankruptcies, breakdowns, macroeconomic and political changes, and disasters leads to higher risks and makes risk management more and more difficult. This paper aims to discuss the theory behind the dry port concep...

  4. Research for Foreign Advanced Ports for Protection and Development Experience

    Science.gov (United States)

    Zhang, Lu; Tian, Mingjing; Zhao, Junjie; Shou, Youping; Wang, Ning; Qiao, Jianzhe; Li, Guanglou

    2018-04-01

    Into the twenty-first century, the process globalization of economic and trade is getting faster and faster, As of 2014, China's annual port trading amount topped the world, But in the port of environmental protection sustainable development approach with foreign advanced port environmental management concept has a big gap. Combined with the present situation of modern ports in China. Drawing lessons from foreign advanced environmental protection idea of port, in order to promote the protection of port environment in our country. The experience of protection and development of foreign advanced port environment will be discussed and discussed.

  5. Occupational hazards to health of port workers.

    Science.gov (United States)

    Wang, Yukun; Zhan, Shuifen; Liu, Yan; Li, Yan

    2017-12-01

    The aim of this article is to reduce the risk of occupational hazards and improve safety conditions by enhancing hazard knowledge and identification as well as improving safety behavior for freight port enterprises. In the article, occupational hazards to health and their prevention measures of freight port enterprises have been summarized through a lot of occupational health evaluation work, experience and understanding. Workers of freight port enterprises confront an equally wide variety of chemical, physical and psychological hazards in production technology, production environment and the course of labor. Such health hazards have been identified, the risks evaluated, the dangers to health notified and effective prevention measures which should be put in place to ensure the health of the port workers summarized. There is still a long way to go for the freight port enterprises to prevent and control the occupational hazards. Except for occupational hazards and their prevention measures, other factors that influence the health of port workers should also be paid attention to, such as age, work history, gender, contraindication and even the occurrence and development rules of occupational hazards in current production conditions.

  6. Classification and prediction of port variables

    Energy Technology Data Exchange (ETDEWEB)

    Molina Serrano, B.

    2016-07-01

    Many variables are included in planning and management of port terminals. They can beeconomic, social, environmental and institutional. Agent needs to know relationshipbetween these variables to modify planning conditions. Use of Bayesian Networks allowsfor classifying, predicting and diagnosing these variables. Bayesian Networks allow forestimating subsequent probability of unknown variables, basing on know variables.In planning level, it means that it is not necessary to know all variables because theirrelationships are known. Agent can know interesting information about how port variablesare connected. It can be interpreted as cause-effect relationship. Bayesian Networks can beused to make optimal decisions by introduction of possible actions and utility of theirresults.In proposed methodology, a data base has been generated with more than 40 port variables.They have been classified in economic, social, environmental and institutional variables, inthe same way that smart port studies in Spanish Port System make. From this data base, anetwork has been generated using a non-cyclic conducted grafo which allows for knowingport variable relationships - parents-children relationships-. Obtained network exhibits thateconomic variables are – in cause-effect terms- cause of rest of variable typologies.Economic variables represent parent role in the most of cases. Moreover, whenenvironmental variables are known, obtained network allows for estimating subsequentprobability of social variables.It has been concluded that Bayesian Networks allow for modeling uncertainty in aprobabilistic way, even when number of variables is high as occurs in planning andmanagement of port terminals. (Author)

  7. Inland Ports in the Republic of Croatia: Approvals for Port Activities instead of Concessions

    Directory of Open Access Journals (Sweden)

    Goran Vojković

    2008-11-01

    Full Text Available According to the 1998 Act on Inland Ports, the right to performall port activities within inland ports of the Republic ofCroatia is given on the basis of concession, obtained throughbidding. It has been noticed in practice that modem businessprocesses and traffic flows are more dynamic than before whenclassic concession relations were created. Also, types andamounts of cargo are changing every couple of years, which isfollowed by quick adjustments, instead of working according torigid and long-term defined decisions and concession contracts.Furthermore, the practice has shown for some activitiesthat the number of port providers (such as ship suppliers,port-agency and freight forwarders should not be limited. Thismeans that the system of a limited number of port providers isimportant only for the activities that require location within aport, as the port area is physically limited. Therefore, the newAct on Navigation and Inland Ports from 2007, whose framehas been completed by sub-law acts during 2008, has replacedthe complex concession system for performing activities in inlandports by a more liberal approval system. On the basis ofthese, higher dynamics of work of port providers is enabled aswell as easier adjustment to market conditions. Furthermore,the main limitation factor that determines the number of portusers becomes the available physical space within a port, whichprovides undisturbed competition, along with larger offer ofport services that do not require that space. It is also importantto point out that the new Act specifically includes distributionand cargo logistics, also processing and improvement of goodsas well as industrial activities including production that enablecomplete economic utilization of port capacities into the existingport activities, thus significantly changing the role of the portitself as a logistic centre.

  8. Shutdown dose rate analysis of European test blanket modules shields in ITER Equatorial Port #16

    Energy Technology Data Exchange (ETDEWEB)

    Juárez, Rafael, E-mail: rjuarez@ind.uned.es [Departamento de Ingeniería Energética, ETSII-UNED, Calle Juan del Rosal 12, Madrid 28040 (Spain); Sauvan, Patrick; Perez, Lucia [Departamento de Ingeniería Energética, ETSII-UNED, Calle Juan del Rosal 12, Madrid 28040 (Spain); Panayotov, Dobromir; Vallory, Joelle; Zmitko, Milan; Poitevin, Yves [Fusion for Energy (F4E), Torres Diagonal Litoral B3, Josep Pla 2, Barcelona 08019 (Spain); Sanz, Javier [Departamento de Ingeniería Energética, ETSII-UNED, Calle Juan del Rosal 12, Madrid 28040 (Spain)

    2016-11-01

    Highlights: • Nuclear analysis for European TBMs and shields, in ITER Equatorial Port #16, has been conducted in support of the ‘Concept Design Review’ from ITER. • The objective of the work is the characterization of the Shutdown Dose Rates at Equatorial Port #16 interspace. • The role played by the TBM and TBM shields, the equatorial port gaps and the vacuum vessel permeation, in terms of neutron flux transmission is assessed. • The role played by the TBM, TBM shields, Port Plug Frame, Pipe Forest and the machine in terms of activation is also investigated. - Abstract: ‘Fusion for Energy’ (F4E) is designing, developing, and implementing the European Helium-Cooled Lead-Lithium (HCLL) and Helium-Cooled Pebble-Bed (HCPB) Test Blanket Systems (TBSs) for ITER (Nuclear Facility INB-174). An essential element of the Conceptual Design Review (CDR) of these TBSs is the demonstration of capability of Test Blanket Modules (TBM) and their shields to fulfil their function and comply with the design requirements. One of the TBM shields highly relevant design aspects is the project target for shutdown dose rates (SDDR) in the interspace. We investigated two functions of the TBMs and TBM shields—the neutron flux attenuation along the shields, and the reduction of the activation of the components contributing to SDDR. It is shown that TBMs and TBM shields reduce significantly the neutron flux in the port plug (PP). In terms of neutron flux attenuation, the TBM shield provides sufficient neutron flux reduction, being responsible for 5 × 10{sup 6} n/cm{sup 2} s at port interspace, while the EPP gaps and BSM gaps are responsible for 5 × 10{sup 7} n/cm{sup 2} s each. When considering closed upper, lower and lateral neighbour equatorial ports (thus, excluding the cross-talk between ports), a SDDR of 121 μSv/h averaged near the port closure flange was obtained, out of which, only 4 μSv/h are due to the activation of TBMs and TBM shields. Maximum SDDR in the range

  9. PHACE syndrome misdiagnosed as a port-wine stain.

    Science.gov (United States)

    Thomson, Jason; Greig, Aina; Lloyd, Claire; Morrison, Danny; Flohr, Carsten

    2015-07-15

    We present the case of a boy born with a large macular, segmental vascular anomaly over the left face, initially diagnosed as a capillary malformation (port-wine stain) by the postnatal paediatric team. The vascular anomaly in the face then grew rapidly during the first few weeks of life and started to occlude the left eye, causing parental concerns about the infant's vision. A dermatological opinion established that the lesion was a segmental infantile haemangioma (IH). This, in combination with the posterior fossa malformation previously detected on antenatal scanning and confirmed by an MRI postnatally, satisfied the criteria for Posterior fossa abnormalities, Haemangiomas, Arterial abnormalities, Cardiac abnormalities and Eye abnormalities (PHACE) syndrome: a rare cutaneous neurovascular syndrome. This case highlights the diagnostic challenge posed by early phenotypes of haemangiomas as well as the importance of correctly diagnosing PHACE syndrome. 2015 BMJ Publishing Group Ltd.

  10. Application of Game Theory and Uncertainty Theory in Port Competition between Hong Kong Port and Shenzhen Port

    Directory of Open Access Journals (Sweden)

    Thi Minh Hoang Do

    2015-06-01

    Full Text Available This paper unveils the strong competition in container cargo between Hong Kong Port which has been emerging as an international maritime center since the 1970s and Shenzhen Port which has recently gained remarkable achievements in the Pearl River Delta region. Among various competing strategies, the study focuses on the long-term one in which two ports will decide to compete by investing in capacity. The purpose of this research is to examine their decision making process and to suggest future strategic actions in the current situation. Within its scope, only economic profit brought back from the investment is considered. For this reason, an uncertain payoff two-person game model is developed where an uncertain factor of demand is involved. In applying Uncertainty theory (Liu, 2013, the two methods to solve the game are introduced, including uncertain statistics and the expected Nash Equilibrium strategy. The results obtained from this research generate meaningful suggestions for future competition plan for the two selected ports, which conclude that Shenzhen is the dominant port in this long-term strategy. Compared to existing works on the same topic, the paper shows its distinctiveness by studying the latest competitive situation with regard to the uncertain demand in the game model.

  11. Adaptive Port Planning under Disruptive Trends with focus on the case of The Port of Kuala Tanjung, Indonesia

    OpenAIRE

    Prakoso Andre; Taneja Poonam; Velinga Tiedo

    2018-01-01

    As a national strategic project, the Port of Kuala Tanjung draws significant attention at national and international level. Considering the semi-greenfield nature of the port, the diverse set of stakeholders, and the prevailing disruptive trends in the world port business, a robust first-phase port layout is required to kick-start the project and guarantee the overall sustainability of the port development. The objective of this research is to identify any uncertain or disruptive trends, both...

  12. Management of Artisanal Fishing Port: a Case Study on Labuhanhaji Fishing Port, South Aceh Regency, Aceh Province

    OpenAIRE

    NurJannah, Betri; ', Syaifuddin; Zain, Jonny

    2014-01-01

    A series survey activity was carried out for evaluating management function atlabuanhaji fishing port, South Aceh regency. This research was emphasis on planning, organizing, action and controlling at management pattern of labuhanhaji fishing port. The facilities of fishing port data and daily activities description of staff at labuhanhaji fishing port was used as additional information and consideration in management of labuhanhaji fishing port. Lack of good management was impact on staff an...

  13. The Re-Conceptualization of the Port Supply Chain as a Smart Port Service System: The Case of the Port of Salerno

    Directory of Open Access Journals (Sweden)

    Antonio Botti

    2017-04-01

    Full Text Available This paper proposes a re-conceptualization of the port supply chain as a smart service system, in accordance with the theory of service science. Starting from a short literature review about the port supply chain approach and service science, a new comprehensive framework is provided to better understand seaport dynamics and the creation of competitive port supply chains. The methodology used is the case study approach. The Authors examined the Port of Salerno (Italy and re-conceptualized it as a smart port service system. The originality of the work lies in the application of service science as a lens to re-conceptualize the port supply chain, that allows the implementation of a logistic framework. Both theoretical and practical implications are provided to enrich the literature about port supply chains and to support port operators.

  14. Nuclear analysis of the ITER Cryopump Ports

    International Nuclear Information System (INIS)

    Moro, Fabio; Villari, Rosaria; Flammini, Davide; Antipenkov, Alexander; Dremel, Matthias; Levesy, Bruno; Loughlin, Michael; Juarez, Rafael; Perez, Lucia; Petrizzi, Luigino

    2015-01-01

    Highlights: • Evaluation the shielding effectiveness of the TCPHs by means of 3-D neutrons and gamma maps. • Assessment of the nuclear heating induced by neutron and photons on the TCP and TCPHs. • Calculation of the dose rate at 12 days after shutdown in the maintenance area of the Lower Ports with the Advanced D1S method, in order to verify the design target (100 μSv/h). • Potential improvements of the shielding configuration aimed at the reduction of the dose level in the Port Cell have been proposed and discussed. - Abstract: The ITER machine will be equipped with 6 torus Cryopumps (TCP) that are positioned in their housings (TCPH) and integrated into the cryostat walls at B1 level in the port cells. A comprehensive nuclear analysis of the Cryopump Ports #4 and #12 has been carried out by means of the MCNP-5 Monte Carlo code in a full 3-D geometry, providing guidelines for the design of the embedded components. Radiation transport calculations have been performed in order to determine the radiation field inside the Lower Ports, up the Port Cell: 3-D neutrons and gamma maps have been provided in order to evaluate the shielding effectiveness of the TCPHs. Nuclear heating induced by neutron and photons have been estimated on the TCP and TCPH to assess the nuclear loads during plasma operations. The shutdown dose rate in the maintenance area of the Lower Ports has been assessed with the Advanced D1S method to verify the design limits.

  15. Nuclear analysis of the ITER Cryopump Ports

    Energy Technology Data Exchange (ETDEWEB)

    Moro, Fabio, E-mail: fabio.moro@enea.it [ENEA, Fusion Technical Unit, Nuclear Technologies Laboratory, Via Enrico Fermi 45, 00044 Frascati, Rome (Italy); Villari, Rosaria; Flammini, Davide [ENEA, Fusion Technical Unit, Nuclear Technologies Laboratory, Via Enrico Fermi 45, 00044 Frascati, Rome (Italy); Antipenkov, Alexander; Dremel, Matthias; Levesy, Bruno; Loughlin, Michael [ITER Organization, Route de Vinon sur Verdon, 13115 Saint Paul-lez-Durance (France); Juarez, Rafael; Perez, Lucia [UNED, Energetic Engineering Department, C/Juan del Rosal 12, Madrid (Spain); Petrizzi, Luigino [European Commission, DG Research & Innovation G5, CDMA 00/030, B-1049 Brussels (Belgium)

    2015-10-15

    Highlights: • Evaluation the shielding effectiveness of the TCPHs by means of 3-D neutrons and gamma maps. • Assessment of the nuclear heating induced by neutron and photons on the TCP and TCPHs. • Calculation of the dose rate at 12 days after shutdown in the maintenance area of the Lower Ports with the Advanced D1S method, in order to verify the design target (100 μSv/h). • Potential improvements of the shielding configuration aimed at the reduction of the dose level in the Port Cell have been proposed and discussed. - Abstract: The ITER machine will be equipped with 6 torus Cryopumps (TCP) that are positioned in their housings (TCPH) and integrated into the cryostat walls at B1 level in the port cells. A comprehensive nuclear analysis of the Cryopump Ports #4 and #12 has been carried out by means of the MCNP-5 Monte Carlo code in a full 3-D geometry, providing guidelines for the design of the embedded components. Radiation transport calculations have been performed in order to determine the radiation field inside the Lower Ports, up the Port Cell: 3-D neutrons and gamma maps have been provided in order to evaluate the shielding effectiveness of the TCPHs. Nuclear heating induced by neutron and photons have been estimated on the TCP and TCPH to assess the nuclear loads during plasma operations. The shutdown dose rate in the maintenance area of the Lower Ports has been assessed with the Advanced D1S method to verify the design limits.

  16. 78 FR 24069 - Safety Zone; 12th Annual Saltwater Classic; Port Canaveral Harbor; Port Canaveral, FL

    Science.gov (United States)

    2013-04-24

    ... under Executive Order 13045, Protection of Children from Environmental Health Risks and Safety Risks. This rule is not an economically significant rule and does not create an environmental risk to health...-AA00 Safety Zone; 12th Annual Saltwater Classic; Port Canaveral Harbor; Port Canaveral, FL AGENCY...

  17. Single port laparoscopic ileocaecal resection for Crohn's disease: a multicentre comparison with multi-port laparoscopy

    NARCIS (Netherlands)

    Carvello, M.; de Groof, E. J.; de Buck van Overstraeten, A.; Sacchi, M.; Wolthuis, A. M.; Buskens, C. J.; D'Hoore, A.; Bemelman, W. A.; Spinelli, A.

    2018-01-01

    AimSingle port (SP) ileocaecal resection (ICR) is an established technique but there are no large studies comparing SP and multi-port (MP) laparoscopic surgery in Crohn's disease (CD). The aim of this study was to compare postoperative pain scores and analgesia requirements after SP and MP

  18. Molecular Diagnostics

    OpenAIRE

    Choe, Hyonmin; Deirmengian, Carl A.; Hickok, Noreen J.; Morrison, Tiffany N.; Tuan, Rocky S.

    2015-01-01

    Orthopaedic infections are complex conditions that require immediate diagnosis and accurate identification of the causative organisms to facilitate appropriate management. Conventional methodologies for diagnosis of these infections sometimes lack accuracy or sufficient rapidity. Current molecular diagnostics are an emerging area of bench-to-bedside research in orthopaedic infections. Examples of promising molecular diagnostics include measurement of a specific biomarker in the synovial fluid...

  19. Venous Access Ports: Indications, Implantation Technique, Follow-Up, and Complications

    Energy Technology Data Exchange (ETDEWEB)

    Walser, Eric M., E-mail: walser.eric@mayo.edu [Mayo Clinic, Department of Radiology (United States)

    2012-08-15

    The subcutaneous venous access device (SVAD or 'port') is a critical component in the care of patients with chronic disease. The modern SVAD provides reliable access for blood withdrawal and medication administration with minimal disruption to a patient's lifestyle. Because of improved materials and catheter technology, today's ports are lighter and stronger and capable of high-pressure injections of contrast for cross-sectional imaging. The majority of SVAD placement occurs in interventional radiology departments due to their ability to provide this service at lower costs, lower, complication rates, and greater volumes. Port-insertion techniques vary depending on the operator, but all consist of catheter placement in the central venous circulation followed by subcutaneous pocket creation and port attachment to the catheter with fixation and closure of the pocket. Venous access challenges occasionally occur in patients with central vein occlusions, necessitating catheterization of collateral veins or port placement in alternate locations. Complications of SVADs include those associated with the procedure as well as short- (<30 days) and long-term problems. Procedural and early complications are quite rare due to the near-universal use of real-time ultrasound guidance for vein puncture, but they can include hematoma, catheter malposition, arrhythmias, and pneumothorax. Late problems include both thrombotic complications (native venous or port-catheter thrombosis) and infections (tunnel or pocket infections or catheter-associated bloodstream infections). Most guidelines suggest that 0.3 infections/1000 catheter days is an appropriate upper threshold for the insertion of SVADs.

  20. Evaluation of the Necessity of Port Fixation in Central Venous Port Implantation

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Sang Su; Kim, Hyung Pil [Inje University Pusan Paik Hospital, Busan (Korea, Republic of); Bae, Jae Ik; Won, Je Hwan [Ajou University School of Medicine, Suwon (Korea, Republic of)

    2010-06-15

    The technical success and complications were especially focused on and evaluated the need for fixation of a port under fluoroscopic guidance placement of the totally implantable central venous access ports for long term central venous access. Two hundred eighty nine consecutive patients (170 men, 119 women, mean age: 52-year-old) who underwent venous port implantation for the administration of chemotherapy were followed over a 1-month period. The procedures were performed in the angiographic suite by an interventional radiologist and all access was through the right jugular vein, except for the patients who had undergone a right mastectomy. The procedures were performed in the following order: 1) venous puncture, 2) making a pocket, 3) catheter tunneling, 4) port insertion, 5) catheter sizing, and 6) insertion. A port which was connected to the tunneled catheter was inserted into the minimally sized subcutaneous pocket with the aid of a small retractor. A follow-up was performed with medical records and chest radiographs. The follow-up period for evaluating the venous port ranged from 59 to 329 days (mean: 175 days) The procedures performed to gain right jugular vein access were successful without difficulty in all cases. The 18 patients that underwent procedures to gain left jugular vein access encountered some difficulty upon insertion of a catheter into the SVC due to encountering the tortuous left brachiocephalic vein. No complications occurred during and immediately after the procedure. In one case the port chamber rotated within the subcutaneous pocket; however, no catheter migration or malfunction occurred. If port insertion was followed by catheter insertion, the port chamber can be tightly implanted in the minimally sized pocket. This would avoid the need for fixation of the catheter to the port chamber leading into the pocket

  1. Dynamism Patterns of Western Mediterranean Cruise Ports and the Coopetition Relationships Between Major Cruise Ports

    Directory of Open Access Journals (Sweden)

    Esteve-Perez Jeronimo

    2018-03-01

    Full Text Available The Mediterranean Sea has seen an increase of ports hosting cruise ships during the first fifteen years of the 21st century. The increase in cruise ship presence in Mediterranean ports is associated with the dynamism of cruise traffic in recent years, with an average annual growth of 7.45% for cruise passengers worldwide during the period of 1990-2015. Cruise traffic is a maritime business that is primarily composed of two elements, maritime affairs and tourism. This article focuses on the maritime component. With the growth of the cruise industry, cruise lines have been forced to seek new ports to meet demand in an attempt to create differentiated products based on the ports that compose the itinerary. The itinerary system of cruise traffic makes the cruise ports depend on one another to design an itinerary. This feature results in both complex geographic relationships in the design of a cruise itinerary and complex competitive/cooperative relationships between ports. The aim of this article is to present the hierarchic picture of a sample of 29 cruise ports in the Western Mediterranean region during the period of 2000-2015. To achieve this goal, a port size classification is proposed and a shift-share analysis at the inter- and intra-group size level is applied. Moreover, concentration measures are used to determine the changes in the levels of market concentration. Furthermore, a dynamic model is proposed to determine the competitive or cooperative relationships between cruise ports. The proposed model is applied to the largest ports with data from the 2001-2015 period.

  2. Pyogenic Granuloma in a Patient of Sturge-Weber Syndrome with Bilateral Port Wine Stain- A Rare Case Report

    Directory of Open Access Journals (Sweden)

    Shantala Arunkumar

    2014-07-01

    Full Text Available Sturge-Weber syndrome (SWS also known as encephalotrigeminal angiomatosis. It is a neurocutaneous syndrome, characterized by a facial vascular birthmark and neurological abnormalities. An ipsilateral or bilateral facial cutaneous vascular malformation Port Wine Stain (PWS usually affects the upper face. Other clinical manifestations are seizures, glaucoma, hemiparesis, mental retardation and delayed developmental milestones. The main objective of this case report is to unravel such a rarest syndrome with bilateral port-wine stain, which has intraoral manifestation of pyogenic granuloma involving gingiva in an 11 year old boy.

  3. Characterization of the radiation field and evaluation of the nuclear responses in the ITER cryopump port cell

    International Nuclear Information System (INIS)

    Moro, Fabio; Villari, Rosaria; Flammini, Davide; Podda, Salvatore; Antipenkov, Alexander; Dremel, Matthias; Levesy, Bruno; Loughlin, Michael; Cambi, Gilio; Cepraga, Dan Gabriel; Petrizzi, Luigino

    2016-01-01

    The ITER main vacuum system consists of six torus exhaust pumps integrated in the Cryostat through dedicated housings at the building B1 level. The Port Cell area outside the cryopump plug is affected by neutrons streaming through the housing structure and diagnostics penetrations. The aim of the study presented in this paper is to perform a complete assessment of the nuclear responses in the Cryopump Port Cell #12 by means of the MCNP-5 Monte Carlo code in a full 3-D geometry. The results of the neutronic analyses provide guidelines for the design and maintenance of the embedded components, ensuring their structural integrity and proper operation. Radiation transport calculations have been carried out to determine the radiation field inside the Port Cell through 3-D neutrons and gamma maps. Nuclear heating induced by neutrons and photons and the absorbed dose during the ITER lifetime on steel and silicon have been estimated in the Port Cell area, in order to assess the nuclear loads that the diagnostics and related electronic components have to withstand. Furthermore, the impact of the gamma-rays emitted by neutron-activated water circulating in the Primary Heat Transfer System have been evaluated on the Port Cell environment: 3-D maps of the gamma flux, nuclear loads on steel/silicon during plasma operation are provided.

  4. Characterization of the radiation field and evaluation of the nuclear responses in the ITER cryopump port cell

    Energy Technology Data Exchange (ETDEWEB)

    Moro, Fabio, E-mail: fabio.moro@enea.it [ENEA, Fusion Technical Unit, Nuclear Technologies Laboratory, 45th Enrico Fermi St., 00044 Frascati, Rome (Italy); Villari, Rosaria; Flammini, Davide; Podda, Salvatore [ENEA, Fusion Technical Unit, Nuclear Technologies Laboratory, 45th Enrico Fermi St., 00044 Frascati, Rome (Italy); Antipenkov, Alexander; Dremel, Matthias; Levesy, Bruno; Loughlin, Michael [ITER Organization, Route de Vinon sur Verdon, 13115 Saint Paul-lez-Durance (France); Cambi, Gilio; Cepraga, Dan Gabriel [Bologna University, Physics Department, 46th Irnerio St., I-401226 Bologna (Italy); Petrizzi, Luigino [European Commission, DG Research & Innovation G5, CDMA 00/030, B-1049 Brussels (Belgium)

    2016-11-01

    The ITER main vacuum system consists of six torus exhaust pumps integrated in the Cryostat through dedicated housings at the building B1 level. The Port Cell area outside the cryopump plug is affected by neutrons streaming through the housing structure and diagnostics penetrations. The aim of the study presented in this paper is to perform a complete assessment of the nuclear responses in the Cryopump Port Cell #12 by means of the MCNP-5 Monte Carlo code in a full 3-D geometry. The results of the neutronic analyses provide guidelines for the design and maintenance of the embedded components, ensuring their structural integrity and proper operation. Radiation transport calculations have been carried out to determine the radiation field inside the Port Cell through 3-D neutrons and gamma maps. Nuclear heating induced by neutrons and photons and the absorbed dose during the ITER lifetime on steel and silicon have been estimated in the Port Cell area, in order to assess the nuclear loads that the diagnostics and related electronic components have to withstand. Furthermore, the impact of the gamma-rays emitted by neutron-activated water circulating in the Primary Heat Transfer System have been evaluated on the Port Cell environment: 3-D maps of the gamma flux, nuclear loads on steel/silicon during plasma operation are provided.

  5. Simulation model for port shunting yards

    Science.gov (United States)

    Rusca, A.; Popa, M.; Rosca, E.; Rosca, M.; Dragu, V.; Rusca, F.

    2016-08-01

    Sea ports are important nodes in the supply chain, joining two high capacity transport modes: rail and maritime transport. The huge cargo flows transiting port requires high capacity construction and installation such as berths, large capacity cranes, respectively shunting yards. However, the port shunting yards specificity raises several problems such as: limited access since these are terminus stations for rail network, the in-output of large transit flows of cargo relatively to the scarcity of the departure/arrival of a ship, as well as limited land availability for implementing solutions to serve these flows. It is necessary to identify technological solutions that lead to an answer to these problems. The paper proposed a simulation model developed with ARENA computer simulation software suitable for shunting yards which serve sea ports with access to the rail network. Are investigates the principal aspects of shunting yards and adequate measures to increase their transit capacity. The operation capacity for shunting yards sub-system is assessed taking in consideration the required operating standards and the measure of performance (e.g. waiting time for freight wagons, number of railway line in station, storage area, etc.) of the railway station are computed. The conclusion and results, drawn from simulation, help transports and logistics specialists to test the proposals for improving the port management.

  6. Specialization and Flexibility in Port Cargo Handling

    Directory of Open Access Journals (Sweden)

    Hakkı KİŞİ

    2016-11-01

    Full Text Available Cargo handling appears to be the fundamental function of ports. In this context, the question of type of equipment and capacity rate need to be tackled with respect to cargo handling principles. The purpose of this study is to discuss the types of equipment to be used in ports, relating the matter to costs and capacity. The question is studied with a basic economic theoretical approach. Various conditions like port location, size, resources, cargo traffic, ships, etc. are given parameters to dictate the type and specification of the cargo handling equipment. Besides, a simple approach in the context of cost capacity relation can be useful in deciding whether to use specialized or flexible equipment. Port equipment is sometimes expected to be flexible to handle various types of cargo as many as possible and sometimes to be specialized to handle one specific type of cargo. The cases that might be suitable for those alternatives are discussed from an economic point of view in this article. Consequently, effectiveness and efficiency criteria play important roles in determining the handling equipment in ports.

  7. Pollution prevention at ports: clearing the air

    International Nuclear Information System (INIS)

    Bailey, Diane; Solomon, Gina

    2004-01-01

    Seaports are major hubs of economic activity and of environmental pollution in coastal urban areas. Due to increasing global trade, transport of goods through ports has been steadily increasing and will likely continue to increase in the future. Evaluating air pollution impacts of ports requires consideration of numerous sources, including marine vessels, trucks, locomotives, and off-road equipment used for moving cargo. The air quality impacts of ports are significant, with particularly large emissions of diesel exhaust, particulate matter, and nitrogen oxides. The health effects of these air pollutants to residents of local communities include asthma, other respiratory diseases, cardiovascular disease, lung cancer, and premature mortality. In children, there are links with asthma, bronchitis, missed school days, and emergency room visits. The significance of these environmental health impacts requires aggressive efforts to mitigate the problem. Approaches to mitigation encompass a range of possibilities from currently available, low-cost approaches, to more significant investments for cleaner air. Examples of the former include restrictions on truck idling and the use of low-sulfur diesel fuel; the latter includes shore-side power for docked ships, and alternative fuels. A precautionary approach to port-related air pollution would encourage local production of goods in order to reduce marine traffic, greener design for new terminals, and state-of-the art approaches to emissions-control that have been successfully demonstrated at ports throughout the world

  8. Fewer-than-four ports versus four ports for laparoscopic cholecystectomy.

    Science.gov (United States)

    Gurusamy, Kurinchi Selvan; Vaughan, Jessica; Rossi, Michele; Davidson, Brian R

    2014-02-20

    Traditionally, laparoscopic cholecystectomy is performed using two 10-mm ports and two 5-mm ports. Recently, a reduction in the number of ports has been suggested as a modification of the standard technique with a view to decreasing pain and improving cosmesis. The safety and effectiveness of using fewer-than-four ports has not yet been established. To assess the benefits (such as improvement in cosmesis and earlier return to activity) and harms (such as increased complications) of using fewer-than-four ports (fewer-than-four-ports laparoscopic cholecystectomy) versus four ports in people undergoing laparoscopic cholecystectomy for any reason (symptomatic gallstones, acalculous cholecystitis, gallbladder polyp, or any other condition). We searched the Cochrane Central Register of Controlled Trials (CENTRAL; Issue 8, 2013), MEDLINE, EMBASE, Science Citation Index Expanded, and the World Health Organization International Clinical Trials Registry Platform portal to September 2013. We included all randomised clinical trials comparing fewer-than-four ports versus four ports, that is, with standard laparoscopic cholecystectomy that is performed with two ports of at least 10-mm incision and two ports of at least 5-mm incision. Two review authors independently identified the trials and extracted the data. We analysed the data using both the fixed-effect and the random-effects models. For each outcome, we calculated the risk ratio (RR) or mean difference (MD) with 95% confidence intervals (CI) based on intention-to-treat analysis, whenever possible. We found nine trials with 855 participants that randomised participants to fewer-than-four-ports laparoscopic cholecystectomy (n = 427) versus four-port laparoscopic cholecystectomy (n = 428). Most trials included low anaesthetic risk participants undergoing elective laparoscopic cholecystectomy. Seven of the nine trials used a single port laparoscopic cholecystectomy and the remaining two trials used three-port laparoscopic

  9. Bouveret's Syndrome: diagnostic considerations

    International Nuclear Information System (INIS)

    Cooper, S.G.; Sherman, S.B.; Steinhardt, J.E.; Wilson, J.M. Jr.; Richman, A.H.

    1987-01-01

    Bouveret's syndrome is a rare disease entity manifested by the formation of a cholecystoduodenal or choledochoduodenal fistula with passage of a gallstone into the duodenal bulb and subsequent obstruction of the gastric outlet. To date, no report of this entity using computed tomographic (CT) imaging is available. This article presents a case of Bouveret's syndrome with the classic findings on upper gastrointestinal (GI) tract series and a description of the CT manifestations. The literature is reviewed with discussion of the diagnostic approach to patients with Bouveret's syndrome

  10. Intra-arterial port implantation for intra-arterial chemotherapy : comparison between PIPS(Percutaneously Implantable Port System) and port system

    International Nuclear Information System (INIS)

    Yoon, Sang Jin; Shim, Hyung Jin; Jung, Hun Young; Choi, Yong Ho; Kim, Yang Soo; Song, In Sup; Kwak, Byung Kook

    1999-01-01

    To compare the techniques and complications of intra-arterial port implantation for intra-arterial chemotherapy between PIPS and the port system. For intra-arterial port implantation, 27 cases in 27 patients were retrospectively evaluated using PIPS(PIPS-200, William Cook Europe, Denmark) while for 21 cases in 19 patients a pediatric venous port system(Port-A-Cath, 5.8F, SIMS Deltec, U. S. A.) was used. All intra-arterial port implantation was performed percuteneously in an angiographic ward. Hepatocellular carcinoma was diagnosed in 18 patients and hepatic metastasis in 16. Peripheral cholangiocarcinoma, and pancreatic gastric, ovarian, renal cell and colon carcinoma were included. We compared the techniques and complications between PIPS and the port system. The follow up period ranged from 23 to 494(mean, 163) days in PIPS and from 12 to 431(mean, 150) days in the port system. In all cases, intra-arterial port implantations were technically successful. Port catheter tips were located in the common hepatic artery(n=8), proper hepatic artery(n=7), right hepatic artery(n=5), gastroduodenal artery(n=2), left hepatic artery(n=1), pancreaticoduodenal artery(n=1), inferior mesenteric artery(n=1), lumbar artery(n=1), and renal artery(n=1) in PIPS, and in the proper hepatic artery(n=6), gastroduodenal artery(n=6), common hepatic artery(n=3), right hepatic artery(n=4), inferior mesenteric artery(n=1), and internal iliac artery(n=1) in the port system. Port chambers were buried in infrainguinal subcutaneous tissue. Using PIPS, complications developed in seven cases(25.9%) and of these, four (57.1%) were catheter or chamber related. In the port system, catheter or chamber related complications developed in four cases(19.0%). Because PIPS and the port system have relative merits and demetrits, successful intra-arterial port implantation is possible if equipment is properly selected

  11. PERFORMANCE ASSESSMENT IN OPERATING DRY PORTS

    Directory of Open Access Journals (Sweden)

    Ciortescu Cezar-Gabriel

    2010-12-01

    Full Text Available In this paper, an approach for recognizing and defining correct and operable performance will be presented with the purpose of evaluating the effectiveness and efficiency of processes in dry ports (inland intermodal hubs. The challenge in evaluating the possible improvements of the underlying processes lies in the special nature and the complex structure of dry ports. It is important to consider that all the processes are highly interconnected and that changes in parameters in one process also have an impact on parameters in other processes. Furthermore, the performance of dry ports, seen as the backbone of the system, has a significant impact on the overall performance of the whole transportation network.

  12. Development Possibilities of the Port of Koper

    Directory of Open Access Journals (Sweden)

    Igor Trupac

    2002-03-01

    Full Text Available The extent to which Slovenia will exploit its good geographictransport position, whether it will be merely a transportcorridor or assume an additional quality (e.g. a distributioncentre or a logistic centre will depend on a cluster of circumstances.The importance will also be laid on how Slovenia willpresent itself and what it will offer to Europe and the rest of theworld. One of its best assets is the Port of Koper (favourable position,good condition, capacities in the frame of the whole logisticsystem.A larger volume of transport and consequently be/fer exploitationof the Port of Koper will in the future depend on increasedtransit. However, to acquire new cargo, the mere installationand modernisation of port infrastructure and rise in thequality of services may not be sufficient: it will also require goodconnections to the hinterland.

  13. Smartphone audio port data collection cookbook

    Directory of Open Access Journals (Sweden)

    Kyle Forinash

    2018-06-01

    Full Text Available The audio port of a smartphone is designed to send and receive audio but can be harnessed for portable, economical, and accurate data collection from a variety of sources. While smartphones have internal sensors to measure a number of physical phenomena such as acceleration, magnetism and illumination levels, measurement of other phenomena such as voltage, external temperature, or accurate timing of moving objects are excluded. The audio port cannot be only employed to sense external phenomena. It has the additional advantage of timing precision; because audio is recorded or played at a controlled rate separated from other smartphone activities, timings based on audio can be highly accurate. The following outlines unpublished details of the audio port technical elements for data collection, a general data collection recipe and an example timing application for Android devices.

  14. INSTITUTIONAL AND MANAGEMENT STRUCTURE OF RUSSIAN ARCTIC SEA PORTS

    Directory of Open Access Journals (Sweden)

    P. A. Bryzgalov

    2012-01-01

    Full Text Available Institutional and management structure of any sea port is a system of interaction between commercial enterprises engaged in cargo operations in port, a subsidiary of Rosmorport FSUE, Sea Port Authority and a number of services (immigration, customs and sanitary-veterinary. Institutional and management structure of some Russian Arctic sea ports is significantly different from the typical one resulting in management problems for these socially significant objects of the Russian Arctic. A plan is proposed to improve the organizational and administrative structure of these ports based on the use of domestic and international experience in port infrastructure management including effective cooperation between the state and the private business.

  15. Port Site Infections After Laparoscopic Cholecystectomy

    Directory of Open Access Journals (Sweden)

    Mumtaz KH Al-Naser

    2017-06-01

    Full Text Available Background: Port site infection (PSI is an infrequent surgical site infection that complicates laparoscopic surgery but has a considerable influence in the overall outcome of laparoscopic cholecystectomy. The aim of this study was to evaluate factors that influence PSI after laparoscopic cholecystectomies and to analyze which of these factors can be modified to avoid PSI in a trail to achieve maximum laparoscopic advantages. Methods: A prospective descriptive qualitative study conducted on patients who underwent laparoscopic cholecystectomies. Swabs were taken for culture & sensitivity in all patients who developed PSI. Exploration under general anaesthesia, for patients, had deep surgical site infections and wound debridement was done, excisional biopsies had been taken for histopathological studies, and tissue samples for polymerase chain reaction for detection of mycobacterium tuberculosis was done. All patients were followed up for six months postoperatively. Factors as gender, site of infected port, type of microorganism, acute versus chronic cholecystitis, type of infection (superficial or deep infection and intraoperative spillage of stones, bile or pus were analyzed in our sample. Results: Port site infection rate was recorded in 40/889 procedures (4.5%, higher rates were observed in male patients 8/89 (8.9%, in acute cholecystitis 13/125 (10.4%, when spillage of bile, stones or pus occurred 24/80 (30%, and at epigastric port 32/40 (80%. Most of the PSI were superficial infections 77.5% with non-specific microorganism 34/40 (85%. Conclusion: There is a significant association of port site infection with spillage of bile, stones, or pus, with the port of gallbladder extraction and with acute cholecystitis. Especial consideration should be taken in chronic deep surgical site infection as mycobacterium tuberculosis could be the cause. Most of the PSIs are superficial and more common in males.

  16. Companion diagnostics

    DEFF Research Database (Denmark)

    Jørgensen, Jan Trøst; Hersom, Maria

    2016-01-01

    of disease mechanisms, things are slowly changing. Within the last few years, we have seen an increasing number of predictive biomarker assays being developed to guide the use of targeted cancer drugs. This type of assay is called companion diagnostics and is developed in parallel to the drug using the drug-diagnostic...... co-development model. The development of companion diagnostics is a relatively new discipline and in this review, different aspects will be discussed including clinical and regulatory issues. Furthermore, examples of drugs, such as the ALK and PD-1/PD-L1 inhibitors, that have been approved recently....... Despite having discussed personalized medicine for more than a decade, we still see that most drug prescriptions for severe chronic diseases are largely based on 'trial and error' and not on solid biomarker data. However, with the advance of molecular diagnostics and a subsequent increased understanding...

  17. Development of the Bosaso Port Somalia

    DEFF Research Database (Denmark)

    Burcharth, Hans F.

    1988-01-01

    The first stage of the port of Bosaso will be completed within half a year's time. It offers accomodation for one general cargo/Ro-Ro vessel of 5,000 DWT plus 350 meters of quays for small cargo vessels and fishing boats. Hinterlands for handling of the goods are arranged along the quays. Areas...... for long term storage of goods and storage of oil are not yet provided. The first stage represents a significant development in the transport system of Somalia in being the most prosperous port in the northern Somalia because of its position at the terminal of the new north-south national main road and its...

  18. Operational Optimization in Port Container Terminals

    DEFF Research Database (Denmark)

    As a result of the significant increase in worldwide containerized transportation the development of efficient handling systems in marine terminals has become very important for port competitiveness. In order to optimize the productivity the total handling time for containers in the terminal must...... be minimized. An overview of the different operational problems in port container terminals is presented and an aggregated model and solution approach is shown. Next, there will be focused on the yard storage problem and a mathematical formulation and solution proposals will be presented....

  19. Remote Handling behind port plug in ITER

    International Nuclear Information System (INIS)

    Bede, O.; Neuberger, H.

    2006-01-01

    Different Test Blanket Modules (TBM) will be used in succession in the same equatorial ports of ITER. The remote handling operations for connection/disconnection of an interface between the port plug of the EU-HCPB-TBM and the port cell equipment are investigated with the goal to reach a quick and simple TBM exchange procedure. This paper describes the operations and systems which are required for connection of the TBM to its supply lines at this interface. The interface is located inside the free space of the port plug flange between the port plug shield and the bioshield of the port cell behind. The approach of the operation place is only available through a narrow gate in the bioshield opened temporarily during maintenance periods. This gate limits the dimensions of the whole system and its tools. The current design of the EU-HCPB-TBM foresees up to 9 supply lines which have to be connected inside the free space of one half of the port plug flange. The connection operations require positioning and adjustment of the tools for each pipe separately. Despite the strict circumstances it is still possible to find such an industrial jointed-arm robot with sufficient payload, which can penetrate into the working area. A mechanical system is necessary to move the robot from its storing place in the hot cell to the port plug on 6 m distance. Each operation requires different end-of-arm tools. The most special one is a pipe positioner tool, which can position and pull the pipe ends to each other and align the tool before welding and hold them in proper position during the welding process. Weld seams can be made by orbital welding tool. The pipe positioner tool has to provide place for welding tool. Using of inbore tool is impossible because pipes have no open ends where the tool could leave it. Orbital tool must be modified to meet requirements of remote handling because it is designed for human handling. The coolant is helium, so for eliminating the leak of helium it is

  20. Upper Gastrointestinal (GI) Series

    Science.gov (United States)

    ... standard barium upper GI series, which uses only barium a double-contrast upper GI series, which uses both air and ... evenly coat your upper GI tract with the barium. If you are having a double-contrast study, you will swallow gas-forming crystals that ...

  1. Strategic Planning for Port Development: Improvement of Container Transit from the Iranian Southern Ports Terminals

    Directory of Open Access Journals (Sweden)

    Homayoun Yousefi

    2013-09-01

    Full Text Available The author attempts to highlight the significance of the Iranian southern ports development strategy planning which allows for the maximum container transit with minimum resources such as service capacities, human resources, and financial potential in order to expand the Iranian container transit. It should be noted that the strategic objectives, the business strategy and its implementation can be arranged only after the port vision and mission obviously delineated. For the purpose of improving the outcome of the ports operational management, it is recommended to concentrate on new strategies such as exploit of transit corridors for development of the Iranian South Ports. The main part of this paper is dedicated to evaluate the role of container transit from the Iranian south ports terminals from various transport corridors in order to improve Maritime Transport in Iran. The importance of defin¬ing the existing and potential competitors at the Persian Gulf and making a comparison between their and our own strengths and weaknesses is of utmost importance. Sometimes, the real business opportunities and threats are placed beyond one’s own line of indus¬try and business. It is therefore necessary to make a careful analysis of the port environment. After the port competition and environment have been analyzed, it would be possible to initiate the building of the SWOT analysis for the Iranian Southern Container Terminals such as Khoramshahr, Imam Khomani, Busher, Bandar Abbas and Chabahar port which have suitable strategic position as transit base in the region. The SWOT analysis method is therefore applied aiming at defining the weaknesses and strengths of the economic subjects as well as opportunities and threats coming from the environment. The next segment of this paper is dedicated to consider the role of dry ports and the International North-South Transit Corridor for the purpose of improving the Iranian container trade.

  2. New technologies for upper tract urothelial carcinoma management

    NARCIS (Netherlands)

    Baard, Joyce; Freund, Jan Erik; de La Rosette, Jean J. M. C. H.; Laguna, Maria P.

    2017-01-01

    Purpose of review Image enhancement techniques and optical diagnostic tools have emerged in the quest to improve diagnostics and treatment in patients with upper urinary tract carcinoma (UTUC). The aim of the present report is to describe their mechanisms of action and to assess the current evidence

  3. Analysis of laparoscopic port site complications: A descriptive study.

    Science.gov (United States)

    Karthik, Somu; Augustine, Alfred Joseph; Shibumon, Mundunadackal Madhavan; Pai, Manohar Varadaraya

    2013-04-01

    The rate of port site complications following conventional laparoscopic surgery is about 21 per 100,000 cases. It has shown a proportional rise with increase in the size of the port site incision and trocar. Although rare, complications that occur at the port site include infection, bleeding, and port site hernia. To determine the morbidity associated with ports at the site of their insertion in laparoscopic surgery and to identify risk factors for complications. Prospective descriptive study. In the present descriptive study, a total of 570 patients who underwent laparoscopic surgeries for various ailments between August 2009 and July 2011 at our institute were observed for port site complications prospectively and the complications were reviewed. Descriptive statistical analysis was carried out in the present study. The statistical software, namely, SPSS 15.0 was used for the analysis of the data. Of the 570 patients undergoing laparoscopic surgery, 17 (3%) had developed complications specifically related to the port site during a minimum follow-up of three months; port site infection (PSI) was the most frequent (n = 10, 1.8%), followed by port site bleeding (n = 4, 0.7%), omentum-related complications (n = 2; 0.35%), and port site metastasis (n = 1, 0.175%). Laparoscopic surgeries are associated with minimal port site complications. Complications are related to the increased number of ports. Umbilical port involvement is the commonest. Most complications are manageable with minimal morbidity, and can be further minimized with meticulous surgical technique during entry and exit.

  4. Status of the SLAC SNOOP diagnostic module for FASTBUS

    International Nuclear Information System (INIS)

    Walz, H.V.; Gustavson, D.B.

    1983-03-01

    A SNOOP Diagnostic Module for FASTBUS is under development at SLAC. The SNOOP Module resides on a FASTBUS crate segment and provides diagnostic monitoring and testing capability. It consists of a high-speed ECL front-end to monitor and single-step segment operations, a simple master interface, and a control processor with two serial communication ports. Module features and specifications are summrized, and prototype hardware is shown

  5. Current epidemiology of hypertension in Port Harcourt metropolis ...

    African Journals Online (AJOL)

    Current epidemiology of hypertension in Port Harcourt metropolis, Rivers State ... the University of Port Harcourt Teaching Hospital formed the cohort for this study. ... is high and only a small fraction of hypertensives are aware of their condition.

  6. Logistics Road map for Smart SeaPorts

    Directory of Open Access Journals (Sweden)

    Khaled Gaber EL Sakty

    2016-12-01

    Full Text Available In the digital world, a smart concept became an essential feature for port organizations to serve as intelligent hubs in the world transport networks.  Smart ports are the trend for the future long-term strategies. Henceforth, ports aims at contributing to sustainable growth by establishing the appropriate conditions for the adoption of new management energy models based on low environmental impact and triggering innovation of both technologies and processes. The scope of this paper is to examine three main issues of smart ports; smart port arctic logistics roadmap, smart port challenges and obstacles in arctic port areas, and the criteria and Key Performance Indicators guiding the assessment of ports against this concept. The main purpose is to develop a smart arctic logistics road map for the future.

  7. An Appraisal of Hospital Based Blood Pressure Control in Port ...

    African Journals Online (AJOL)

    Alasia Datonye

    Department of Internal Medicine, College of Health Sciences, University of Port Harcourt,. Port Harcourt ... The assessment of hypertension control and evaluation of the impact of poor ..... An updated coronary risk profile: A statement from.

  8. The “diamond port configuration”: A standardised laparoscopic ...

    African Journals Online (AJOL)

    This covered patient position, port insertion, technical aspects of intestinal resection and perioperative management. In particular, a diamond configuration for ports was agreed upon. Data were prospectively collected, and included patient demographics, operative times, conversion rates and postoperative outcomes.

  9. Deepwater Ports in US waters as of August 2013

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The Deepwater Port Licensing Program is the application process designed to promote the construction of LNG and oil deepwater ports. This license system was...

  10. System аnalysis concession maritime trade ports

    Directory of Open Access Journals (Sweden)

    Y.V. Shmatock

    2015-03-01

    Full Text Available The article proves the significance of maritime commercial ports as strategic for the country. The urgency of port concessions to improve transport infrastructure. The definition of ports in terms of system analysis and determination of management port. Outlined the sequence of system analysis concessions maritime trade ports in the table. Selection of qualified managers is based on the concession tender under prescribed conditions. These criteria should be considered when determining the concessionaire. These stages of the concession tender. Meeting the needs of the economy, international trade, public inquiries into transportation of goods is not possible without the efficient operation of maritime trade ports. Only complex technological modernization of maritime trade ports will enable them to take leadership positions. Tree depicted objectives effectively manage commercial sea port. Therefore, initiation of concessions needs to implement measures to achieve the talented and skillful result.

  11. FHWA operations support : port peak pricing program evaluation

    Science.gov (United States)

    2009-01-01

    This report evaluates the applicability, Federal policy implications, and possible public and private sector roles related to peak pricing strategies at ports and intermodal facilities in the U.S. A number of ports and intermodal terminals are consid...

  12. Radiation and Shipping Port Security | RadTown USA | US ...

    Science.gov (United States)

    2017-08-07

    Cargo comes into the U.S. from all over the world. Ports can ensure safety by: Screening cargo for radiation before it gets here. Safely handling any radioactive material that needs to pass through a port.

  13. The Port Elizabeth Electric Tramway Case: Is the Meaning Ascribed ...

    African Journals Online (AJOL)

    The Port Elizabeth Electric Tramway Case: Is the Meaning Ascribed to the Phrase “In the Production of the Income” By Watermeyer AJP in the Port Elizabeth Electric Tramway Case Still Religiously Followed Today?

  14. Port wine stain on a child's face (image)

    Science.gov (United States)

    Port wine stains are always present at birth. In an infant, they are flat, pink, vascular lesions. Common locations ... may be present anywhere on the body. Port wine stains may appear in association with other syndromes.

  15. Plasma Diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Zaveryaev, V [Kurchatov Institute, Moscow (Russian Federation); others, and

    2012-09-15

    The success in achieving peaceful fusion power depends on the ability to control a high temperature plasma, which is an object with unique properties, possibly the most complicated object created by humans. Over years of fusion research a new branch of science has been created, namely plasma diagnostics, which involves knowledge of almost all fields of physics, from electromagnetism to nuclear physics, and up-to-date progress in engineering and technology (materials, electronics, mathematical methods of data treatment). Historically, work on controlled fusion started with pulsed systems and accordingly the methods of plasma parameter measurement were first developed for short lived and dense plasmas. Magnetically confined hot plasmas require the creation of special experimental techniques for diagnostics. The diagnostic set is the most scientifically intensive part of a plasma device. During many years of research operation some scientific tasks have been solved while new ones arose. New tasks often require significant changes in the diagnostic system, which is thus a very flexible part of plasma machines. Diagnostic systems are designed to solve several tasks. As an example here are the diagnostic tasks for the International Thermonuclear Experimental Reactor - ITER: (1) Measurements for machine protection and basic control; (2) Measurements for advanced control; (3) Additional measurements for performance evaluation and physics. Every new plasma machine is a further step along the path to the main goal - controlled fusion - and nobody knows in advance what new phenomena will be met on the way. So in the planning of diagnostic construction we should keep in mind further system upgrading to meet possible new scientific and technical challenges. (author)

  16. Reduced-port robotic total mesorectal resection for rectal cancer using a single-port access: a technical note.

    Science.gov (United States)

    Bae, Sung Uk; Jeong, Woon Kyung; Baek, Seong Kyu

    2017-12-01

    Single-port laparoscopic surgery has some advantages, including improved cosmetic outcomes and minimized parietal trauma. However, pure single-port laparoscopic rectal cancer surgery is challenging because of the difficulties in creating triangulation and applying the laparoscopic staplers with sufficient distal margins in the narrow pelvic cavity. Recently, a reduced-port robotic operation with a robotic single-port access plus one wristed robotic arm for colon cancer was introduced to overcome the limitations of single-port laparoscopic rectal surgery. Single-port laparoscopic surgery has some advantages, including improved cosmetic outcomes and minimized parietal trauma. However, the pure single-port laparoscopic rectal cancer operation is challenging. Recently, a reduced-port robotic operation with a robotic single-port access plus one wristed robotic arm for colon cancer was introduced to overcome the limitations of single-port laparoscopic rectal surgery. We performed a single-port plus an additional port robotic operation using a robotic single-port access through the umbilical incision, and the wristed robotic instruments were inserted through an additional robotic port in the right lower quadrant. The total operative and docking times were 310 min and 25 min, respectively. The total number of lymph nodes harvested was 12, and the proximal and distal resection margins were 11.1 and 2 cm, respectively. The patient was discharged on postoperative day 12 uneventfully. Based on a representative case, reduced-port robotic total mesorectal excision for rectal cancer using the single-port access appears to be feasible and safe. This approach could overcome the limitations of single-port laparoscopic rectal surgery.

  17. Mechanical design and thermo-hydraulic simulation of the infrared thermography diagnostic of the WEST tokamak

    Energy Technology Data Exchange (ETDEWEB)

    Micolon, Frédéric, E-mail: frederic.micolon@cea.fr; Courtois, Xavier; Aumeunier, Marie-Hélène; Chenevois, Jean-Pierre; Larroque, Sébastien

    2015-10-15

    The WEST (Tungsten (W) Environment in Steady state Tokamak) project is a partial rebuild of the Tore Supra tokamak to make it an X-point metallic environment machine aimed at testing ITER technologies in relevant plasma environment. For the safe operation of the WEST tokamak, infra-red (IR) thermography is a crucial diagnostic as it is a sound and reliable way to detect hotspots or abnormal heating patterns on the plasma facing components (PFCs). Thus WEST will be fitted with middle/short-IR (1.5–2 μm or 3–5 μm) cameras in the upper port plugs to get a full view of the critical PFCs (in particular the new lower divertor) and radio-frequency (RF) heating antennas and one camera at the equatorial level to monitor the new upper divertor and the first wall. This paper describes the design of the up-to-date optical system along with the hydraulic analysis and the thermal and mechanical finite element analysis conducted to ensure adequate heat extraction capabilities. Boundary conditions and simulation results will be presented and discussed as well as technological solutions retained.

  18. Adaptive control of port-Hamiltonian systems

    NARCIS (Netherlands)

    Dirksz, D.A.; Scherpen, J.M.A.; Edelmayer, András

    2010-01-01

    In this paper an adaptive control scheme is presented for general port-Hamiltonian systems. Adaptive control is used to compensate for control errors that are caused by unknown or uncertain parameter values of a system. The adaptive control is also combined with canonical transformation theory for

  19. Sewage Disposal in Port Harcourt, Nigeria.

    Science.gov (United States)

    Ayotamuno, M. J.

    1993-01-01

    This survey of the Port Harcourt, Nigeria, sewage disposal system exemplifies sewage disposal in the developing world. Results reveal that some well-constructed and maintained drains, as well as many open drains and septic tanks, expose women and children to the possibility of direct contact with parasitic organisms and threaten water resources.…

  20. Transparency in port-Hamiltonian based telemanipulation

    NARCIS (Netherlands)

    Secchi, C; Stramigioli, Stefano; Fantuzzi, C.

    2005-01-01

    After stability, transparency is the major issue in the design of a telemanipulation system. In this paper we exploit a behavioral approach in order to provide an index for the evaluation of transparency in port-Hamiltonian based teleoperators. Furthermore we provide a transparency analysis of

  1. Transparency in Port-Hamiltonian-Based Telemanipulation

    NARCIS (Netherlands)

    Secchi, Cristian; Stramigioli, Stefano; Fantuzzi, Cesare

    After stability, transparency is the major issue in the design of a telemanipulation system. In this paper, we exploit the behavioral approach in order to provide an index for the evaluation of transparency in port-Hamiltonian-based teleoperators. Furthermore, we provide a transparency analysis of

  2. Guidance on Port Biological Baseline Surveys (PBBS)

    Digital Repository Service at National Institute of Oceanography (India)

    Awad, A.; Haag, F.; Anil, A.C.; Abdulla, A.

    This publication has been prepared by GBP, IOI, CSIR-NIO and IUCN in order to serve as guidance to those who are planning to carry out a port biological baseline survey, in particular in the context of Ballast Water Management. It has been drafted...

  3. Remote Identification of Port Scan Toolchains

    NARCIS (Netherlands)

    Ghiëtte, Vincent; Blenn, N.; Doerr, C.; Badra, Mohamad; Pau, Giovanni; Vassiliou, Vasos

    2016-01-01

    Port scans are typically at the begin of a chain of events that will lead to the attack and exploitation of a host over a network. Since building an effective defense relies on information what kind of threat an organization is facing, threat intelligence outlining an actor’s modus operandi is a

  4. Stuctures in hydraulic engineering : Port Infrastructure

    NARCIS (Netherlands)

    de Gijt, J.G.

    2007-01-01

    Lecture notes on the planning and design of port infrastructure, like quay walls as gravity structures, sheet-piles, jetties and ro-ro facilties; anchoring of walls. Discussion of the loads on quay walls, jetties and dolphins. Construction of quay walls. Risk analysis, fender design. Scour problems

  5. Port Hamiltonian modeling of Power Networks

    NARCIS (Netherlands)

    van Schaik, F.; van der Schaft, Abraham; Scherpen, Jacquelien M.A.; Zonetti, Daniele; Ortega, R

    2012-01-01

    In this talk a full nonlinear model for the power network in port–Hamiltonian framework is derived to study its stability properties. For this we use the modularity approach i.e., we first derive the models of individual components in power network as port-Hamiltonian systems and then we combine all

  6. Agile Port and High Speed Ship Technologies

    Science.gov (United States)

    2009-12-31

    Alternative Shipboard Powering Systems for Naval and Regulatory Review • The Evaluation and Implementation Plan for Southern California Maglev ...Ackerman". CSULB Foundation Annual Report. CSULB Foundation, Long Beach, CA. December 2005. " Maglev Technology ’Conveys’ Port Transportation Solutions...34. Newsflash. College of Engineering, California State University, Long Beach. Cover page. Spring 2006 Hanson, Kristopher. "Engineers Tout Maglev at

  7. The Global View on Port State Control

    NARCIS (Netherlands)

    S. Knapp (Sabine); Ph.H.B.F. Franses (Philip Hans)

    2006-01-01

    textabstractThis report is the second part of a PhD project entitled "The Econometrics of Maritime Safety – Recommendations to Enhance Safety at Sea" which is based on 183,000 port state control inspections and 11,700 casualties from various data sources. Its overall objective is to provide

  8. Photoacoustic imaging of port-wine stains

    NARCIS (Netherlands)

    Kolkman, Roy G. M.; Mulder, Miranda J.; Glade, Conrad P.; Steenbergen, Wiendelt; van Leeuwen, Ton G.

    2008-01-01

    BACKGROUND AND OBJECTIVE: To optimize laser therapy of port-wine stains (PWSs), information about the vasculature as well as lesion depth is valuable. In this study we investigated the use of photoacoustic imaging (PAI) to obtain this information. STUDY DESIGN/MATERIALS AND METHODS: PAI uses pulsed

  9. Photoacoustic Imaging of Port-Wine Stains

    NARCIS (Netherlands)

    Kolkman, R.G.M.; Mulder, M.J.; Mulder, Miranda J.; Glade, Conrad P.; Steenbergen, Wiendelt; van Leeuwen, Ton

    2008-01-01

    Background and Objective: To optimize laser therapy of port-wine stains (PWSs), information about the vasculature as well as lesion depth is valuable. In this study we investigated the use of photoacoustic imaging (PAI) to obtain this information. - Study Design/Materials and Methods: PAI uses

  10. Structures in hydraulic engineering : Port Infrastructure

    NARCIS (Netherlands)

    de Gijt, J.G.

    2004-01-01

    In history harbours were places of 'natural' shelter, ships could be safely anchored, however loading and unloading facilities were generally non existent apart from human labour. On the other hand ports are man made places of shelter purpose built for efficient transfer of cargo. The distinction

  11. Port-Hamiltonian Systems on Open Graphs

    NARCIS (Netherlands)

    Schaft, A.J. van der; Maschke, B.M.

    2010-01-01

    In this talk we discuss how to define in an intrinsic manner port-Hamiltonian dynamics on open graphs. Open graphs are graphs where some of the vertices are boundary vertices (terminals), which allow interconnection with other systems. We show that a directed graph carries two natural Dirac

  12. Role of Flexibility in Sustainable Port Development

    NARCIS (Netherlands)

    Taneja, P.; Vellinga, T.; Ros, R.

    2012-01-01

    Sustainability has become a high profile objective in all aspects of our lives, including the development of our infrastructures. Flexibility can enhance sustainability endeavors, yet its contribution is not clear to most. In this paper we investigate the role of flexibility in sustainable port

  13. 33 CFR 165.761 - Security Zones; Port of Palm Beach, Port Everglades, Port of Miami, and Port of Key West, Florida.

    Science.gov (United States)

    2010-07-01

    ... of the law enforcement boats and cruise ship tenders which will mark a transit lane in channel. (ii... east of the law enforcement vessels and cruise ship tenders, which will mark a transit lane in the..., tug boats and contracted security vessels may assist the Coast Guard Captain of the Port under the...

  14. Single port access for laparoscopic lateral segmentectomy.

    Science.gov (United States)

    Inoue, Yoshihiro; Asakuma, Mitsuhiro; Hirokawa, Fumitoshi; Hayashi, Michihiro; Shimizu, Tetsunosuke; Uchiyama, Kazuhisa

    2017-12-01

    Single-port access laparoscopic lateral segmentectomy (LLS) has been developed as a novel minimally invasive surgery. We have experience with this LLS technique. To report our technique and patients' postoperative course in a series of single-port access LLS performed in our department. We also examine the cosmetic outcome, safety, and utility of the procedure. Between February 2010 and October 2016, 54 patients who underwent single- or multiple-port laparoscopic or open lateral segmentectomy (LS) were retrospectively analyzed with respect to cosmetic outcome, safety, and utility. In the single LLS group, the laparoscopic procedure was successfully completed for all 14 patients. The median operative time was significantly shorter in the single LLS group (123 min; range: 50-270 min) than in the other groups. Estimated blood loss was also significantly lower in the single LLS group (10 ml; range: 0-330 ml). During the first 7 postoperative days, the visual analog scale pain score and the use of additional analgesia were not significantly different between groups. The single LLS group had a 7.1% complication rate (Clavien-Dindo classification > IIIA); this was not significantly different between groups. Single-port access LLS is a procedure with excellent cosmetic results, although, with regard to invasiveness, there are no major differences from conventional LLS.

  15. HomePort ZigBee Adapter

    DEFF Research Database (Denmark)

    Pedersen, Thomas; Smedegaard, Jacob Haubach; Hansen, Rene

    the existing tool, Homeport, to act as a middleware and bridge between ConLAN's existing network and the ZigBee network. This report primarily discusses three possible solutions for constructing this bridge and current status on the implementation of a Develco SmartAMM and Zigbee stack for HomePort....

  16. Optimizing yard operations in port container terminals

    DEFF Research Database (Denmark)

    Kallehauge, Louise Sibbesen

    2005-01-01

    This paper deals with the problem of positioning containers in a yard block of a port container terminal. The objective of the container positioning problem (CPP) is to minimise the total handling time in the block, i.e. the time required for storage and reshuffling of containers. One...

  17. Regional Hub port development : the case of Montevideo, Uruguay

    OpenAIRE

    Wilmsmeier, Gordon; Martínez Zarzoso, Inmaculada; Fiess, Norbert

    2011-01-01

    This paper reflects on port development in Uruguay in an environment of trilateral interport competition. The regional characteristics of port development in terms of their geographical, functional and operational characteristics are discussed by analysing the port system’s evolution. The case of Montevideo as the success or failure of a regional hub port development strategy is analysed in detail. Particular attention is given to the evolution and impact of the liner shipping service network...

  18. Process for evaluating overweight truck corridors serving coastal port regions and border ports of entry

    Science.gov (United States)

    2017-08-01

    Coastal and inland ports, regional mobility authorities, cities, and counties located near or along the Texas Gulf Coast, and along the border with Mexico, have been granted authority by the state legislature to establish permitted overweight truck c...

  19. National Port Strategy Assessment: Reducing Air Pollution and Greenhouse Gases at U.S. Ports

    Science.gov (United States)

    The assessment finds that air pollution at the Nation's ports can be significantly reduced by implementing currently available strategies and technologies to reduce emissions of harmful pollutants from diesel vehicles and engines.

  20. Wounds caused by contact with muzzle-lift relief ports (Mag-Na-Port).

    Science.gov (United States)

    Rogers, D R; Shem, R J

    1992-12-01

    Fan-shaped stippled burns were produced on the skin when a revolver whose barrel had been modified by the Mag-Na-Port process was fired twice with the side of the muzzle in contact. A grazing wound was produced by one bullet, and an oblique entry was produced by the other. The characteristics of Mag-Na-Port wounds and test shots are described, and these are compared with test shots from two other higher power revolvers.

  1. The Development of the Regional Sea Port Infrastructure on the Basis of Dry Port

    Directory of Open Access Journals (Sweden)

    Aleksandr Nelevich Rakhmangulov

    2016-09-01

    Full Text Available This article contributes to the solution of the relevant problem of the seaport infrastructure development for the purpose of increasing the cargo turnover in the regions of seaport location as well as to improve the quality of freight traffic on the basis of the creation of container hinterlands — dry ports. The options of dry ports as the potentially effective solution to increase the cargo turnover of existing seaports, improve the timeliness of freight transportation and overcome the environmental problems of the regions of seaport location are shown. This work analyzes the transport infrastructure of the region, the cargo turnover of major Russian sea and dry ports as well as the experience of creating dry ports in the Russian Federation and abroad. The authors propose the system of parameters for dry ports, which are recommended for the assessment of seaport infrastructure development scenarios on the stage of strategic planning. The authors have developed the approach of optimal values determination of the main parameters of dry ports by simulation modeling method. The features of construction and research of the simulation models of system “seaport — dry port” in programming software AnyLogic are considered. The results of modeling experiments with a developed simulation model are provided. This model is aimed to assess the maximum estimated capacity of the existing seaport in the conditions of the increasing irregularity of cargo traffic, and also to determine the optimum parameters of the constructed «dry port». The obtained dependencies as a result of modeling experiments prove the adequacy of the selected main parameters of dry ports for the effective evaluation of the scenarios of the strengthening of carrying and estimated capacity of existing seaports on the stage of strategic planning. The article shows that the methodology of this research can be used by the investors and public authorities as grounds for a decision on

  2. Hub port competition and welfare effects of strategic privatization

    NARCIS (Netherlands)

    Czerny, A.I.; Hoffler, F.; Mun, S.

    2014-01-01

    Private operation of port facilities is becoming increasingly common worldwide. We investigate the effect of port privatization in a setting with two ports located in different countries, each serving their home market but also competing for the transshipment traffic from a third region. Each

  3. Performance Effects of the Corporatisation of Port of Rotterdam Authority

    NARCIS (Netherlands)

    P.W. de Langen (Peter); C. Heij (Christiaan)

    2013-01-01

    textabstractPort of Rotterdam Authority is a publicly owned but corporatized port development company. In 2004, this organisation was transformed from a municipal department to an independently operating company. The corporatisation intended to improve the overall performance of the port of

  4. Diagnostic development

    International Nuclear Information System (INIS)

    Barnett, C.F.; Brisson, D.A.; Greco, S.E.

    1978-01-01

    During the past year the far-infrared or submillimeter diagnostic research program resulted in three major developments: (1) an optically pumped 0.385-μm D 2 O-laser oscillator-amplifier system was operated at a power level of 1 MW with a line width of less than 50 MHz; (2) a conical Pyrex submillimeter laser beam dump with a retention efficiency greater than 10 4 was developed for the ion temperature Thompson scattering experiment; and (3) a new diagnostic technique was developed that makes use of the Faraday rotation of a modulated submillimeter laser beam to determine plasma current profile. Measurements of the asymmetric distortion of the H/sub α/ (6563 A) spectral line profile show that the effective toroidal drift velocity, dv/sub two vertical bars i/dT/sub i/, may be used as an indicator of plasma quality and as a complement to other ion temperature diagnostics

  5. Non-Price Competition in the Port Sector: A Case Study of Ports in Turkey

    Directory of Open Access Journals (Sweden)

    Soner Esmer

    2016-03-01

    Full Text Available Although the port sector has been facing increasing competition, there is limited research on how ports compete using non-price competition strategies. There are a few studies on non-price competition in the port sector. However they mainly focus on the marketing aspect. This paper seeks to fill this gap in the literature, especially from a combined marketing-economic perspective. Especially the paper's main objective is to identify the determinants of non-price competition in the port sector and evaluate their effect on various aspects of non-price competition. We start with a general conceptual framework to explain how competition in the sector can be affected by various factors and then propose an analytical framework on non-price competition. The analytical model is then used to support the design of a survey questionnaire. Next, hypothesis tests are conducted using exploratory factor analysis (EFA and structural equation modeling (SEM and data collected from a survey of Turkish ports. Based on the analysis results, the implications for port management and future research are also discussed.

  6. Carbonaceous particles and aerosol mass closure in PM2.5 collected in a port city

    Science.gov (United States)

    Genga, A.; Ielpo, P.; Siciliano, T.; Siciliano, M.

    2017-01-01

    Mass concentrations of PM2.5, mineral dust, organic carbon (OC) and elemental carbon (EC), water-soluble organic carbon (WSOC), sea salts and anthropogenic metals have been studied in a city-port of south Italy (Brindisi). This city is characterized by different emission sources (ship, vehicular traffic, biomass burning and industrial emissions) and it is an important port and industrial site of the Adriatic sea. Based on diagnostic ratios of carbonaceous species we assess the presence of biomass burning emissions (BBE), fossil fuel emissions (FFE) and ship emission (SE). Our proposed conversion factors from OC to OM are higher than those reported in the literature for urban site: the reason of this could be due to the existence of aged combustion aerosols during the sampling campaign (WSOC/OC = 0.6 ± 0.3).

  7. Adaptive Port Planning under Disruptive Trends with focus on the case of the Port of Kuala Tanjung, Indonesia

    NARCIS (Netherlands)

    Taneja, P.; Velinga, Tiedo

    2018-01-01

    As a national strategic project, the Port of Kuala Tanjung draws significant attention at national and international level. Considering the semi-greenfield nature of the port, the diverse set of stakeholders, and the prevailing disruptive trends in the world port business, a robust first-phase

  8. Diagnostic dilemma

    DEFF Research Database (Denmark)

    Feldt-Rasmussen, Ulla; Dobrovolny, Robert; Nazarenko, Irina

    2011-01-01

    Fabry disease, an X-linked lysosomal storage disorder, results from the deficient activity of a-galactosidase A (a-Gal A). In affected males, the clinical diagnosis is confirmed by the markedly decreased a-Gal A activity. However, in female heterozygotes, the a-Gal A activity can range from low t...... on enzyme replacement therapy. Thus, gene dosage analyses can detect large deletions (>50bp) in suspect heterozygotes for X-linked and autosomal dominant diseases that are "sequencing cryptic," resolving molecular diagnostic dilemmas....... to normal due to random X-chromosomal inactivation, and diagnostic confirmation requires identification of the family's a-Gal A gene mutation. In a young female who had occasional acroparesthesias, corneal opacities, and 15 to 50% of the lower limit of normal leukocyte a-Gal A activity, a-Gal A sequencing...... in two expert laboratories did not identify a confirmatory mutation, presenting a diagnostic dilemma. A renal biopsy proved diagnostic and renewed efforts to detect an a-Gal A mutation. Subsequent gene dosage analyses identified a large a-Gal A deletion confirming her heterozygosity, and she was started...

  9. PC interfacing using Centronics, RS232 and game ports

    CERN Document Server

    An, Pei

    1998-01-01

    The main links with your PC and the outside world are the centronic port, used for connecting the printer, the RS232 port, used for the mouse, and the games port for a joystick. This book explores how these input/output (I/O) ports can be put to use through a range of other interfacing applications. This is especially useful for laptop and palmtop PCs which cannot be fitted with internal I/O cards. A novel approach is taken by this book, combining the hardware through which the ports can be explored, and the software programming needed to carry out a range of experiments.Circuits are p

  10. The Port Hope area initiative municipal involvement

    International Nuclear Information System (INIS)

    Austin, Rick; Stevenson, Mark

    2006-01-01

    Port Hope (Canada) contains one of the world's oldest nuclear facility sites. From the 1930's through to the 1970's, processing residues from radium refining facilities located at the Port Hope Harbour were being stored and/or deposited on numerous sites throughout the municipality. For a variety of reasons, including spillage of material during transportation and un-monitored or unauthorized diversion of materials, many private and public properties in the municipality were contaminated with low level radioactive waste. Over the past 30 years, the community has demanded that the nuclear industry and the federal government clean up the mess left in Port Hope. In the 1980's and 1990's, the federal government sought to fulfill its commitment to clean up over one million cubic metres of contaminated material remaining in Port Hope but was unable to find a solution. The Low Level Radioactive Waste Management Siting Task Force worked in trying to find a home for historic LLRW in the 1980's and 1990's. It is only within the past 6 years that Port Hope's community began to see the 'light at the end of the tunnel'. And, the light began to shine when the communities took the issue of long term management of the waste into their own hands and proposed possible solutions to the federal government. So the Port Hope Area Initiative is a community-based initiative. In this paper the author presents some of the reasons for success (so far) and some opportunities and challenges that his municipality, and specifically municipal Council, faces as a partner in this Environmental Assessment and project development process. He addresses some of the key elements of the Project that he believes have led to the success of the Project to this point, including: the Legal Agreement and Agreement Monitoring process; the Property Value Protection Program; the Hosting Fee; the Municipal veto on some decisions; the end Use as an asset to the Community; the Value of Peer Review. He also touches

  11. Benchmark dynamics in the environmental performance of ports.

    Science.gov (United States)

    Puig, Martí; Michail, Antonis; Wooldridge, Chris; Darbra, Rosa Mari

    2017-08-15

    This paper analyses the 2016 environmental benchmark performance of the port sector, based on a wide representation of EcoPorts members. This is the fifth time that this study has been conducted as an initiative of the European Sea Ports Organisation (ESPO). The data and results are derived from the Self-Diagnosis Method (SDM), a concise checklist against which port managers can self-assess the environmental management of their port in relation to the performance of the EcoPorts membership. The SDM tool was developed in the framework of the ECOPORTS project (2002-2005) and it is managed by ESPO. A total number of 91 ports from 20 different European Maritime States contributed to this evaluation. The main results are that air quality remains as the top environmental priority of the respondent ports, followed by energy consumption and noise. In terms of environmental management, the study confirms that key components are commonly implemented in the majority of European ports. 94% of contributing ports have a designated environmental manager, 92% own an environmental policy and 82% implement an environmental monitoring program. Waste is identified as the most monitored issue in ports (80%), followed by energy consumption (73%) and water quality (70%). Copyright © 2017 Elsevier Ltd. All rights reserved.

  12. [Clinical retrospective control study of single-port laparoendoscopic and multi-port laparoscopic ovarian cystectomy].

    Science.gov (United States)

    Liu, X; Wen, M K; Liu, H Y; Sun, D W; Lang, J H; Fan, Q B; Shi, H H

    2017-10-25

    Objective: To investigate clinical outcomes of laparoendoscopic single-site ovarian cystectomy compared with traditional multi-port laparoscopic ovarian cystectomy. Methods: Data of 81 patients with ovarian cystectomy from January 2016 to May 2017, the single-site group ( n= 40) and the multi-port group ( n= 41) in Peking Union Medical College Hospital were retrospectively collected. The outcomes of single-site and multi-port groups were analyzed and compared, including: postoperative fever, operation time, blood loss, hemoglobin change, surgical complications, postoperative pain score, postoperative analgesic requirements, body image scale and cosmetic score, length of hospital stay, postoperative total cost. Results: No complication was found in two groups. No difference was found in postoperative fever, blood loss, hemoglobin change, postoperative pain score, length of hospital stay, and total cost between the two groups (all P> 0.05). Operation time was (50±20) minutes in single-site group, and (40±15) minutes in multi-port group; postoperative analgesic requirements was 28%(11/40) in single-site group, and 7%(4/41) in multi-port group; cosmetic score was 22.6±2.6 in single-site group, and 17.3±2.6 in multi-port group; body image scale was 5.7±1.2 in single-site group, and 6.2±1.2 in multi-port group; these four clinical parameters were statistical differences (all P< 0.05). Conculsion: Laparoendoscopic single-site ovarian cystectomy is feasible and safe, although it could't relieve the postoperative pian, it do offer a higher cosmetic satisfaction.

  13. Robotic right middle lobectomy with a subxiphoid utility port.

    Science.gov (United States)

    Jayakumar, Shruti; Nardini, Marco; Papoulidis, Pavlos; Dunning, Joel

    2018-06-01

    We present the case of a 74-year-old man with Stage IIa pulmonary adenocarcinoma, for which he underwent a robotic right middle lobectomy. A 4-armed, 5-port approach was used. Four intercostal ports were created above the ninth rib using the Cerfolio's technique. The subxiphoid port was created in the midline, 5 cm down from the xiphisternum. The robot offers higher image quality, depth perception and improved articulation of the instruments, allowing for more accurate dissection and stitching. The usage of a subxiphoid utility port reduces the clashing between instruments, offers a good angle for stapling and provides a direct view of the instruments entering into the chest. Specimen removal through the subxiphoid port may reduce postoperative pain and enhance patient recovery. The use of the subxiphoid approach as a utility port for robotic surgery is promising and may be a suitable replacement for the traditional utility port.

  14. Feasibility of Reduced Port Laparoscopic Colectomy for Colon Cancer.

    Science.gov (United States)

    Tsutsumi, Soichi; Morita, Hiroki; Fujii, Takaaki; Suto, Toshinaga; Yajima, Reina; Takada, Takahiro; Asao, Takayuki; Kuwano, Hiroyuki

    2015-06-01

    Reduced port laparoscopic surgery has recently emerged as a method to improve the cosmetic results of conventional laparoscopic surgery. We reported our technique of reduced port laparoscopic colectomy using 3-port and short-time outcomes. Between 2005 and 2012, we performed 161 reduced port laparoscopic colectomies using the 3-port technique. Data analyzed in-cluded age, gender, body mass index (BMI), duration of surgery, number of harvested lymph nodes, and duration of hospital stay. All of the cases were successfully performed using the 3-port procedure. The median durations of surgery and postoperative hospital stay were 140 mm (range 75-463 mm) and 9 days (range 5-38 days), respectively. No mortality was associated with this technique. Reduced port laparoscopic colectomy is feasible and may have advantages over conventional laparoscopic colectomy.

  15. Port performance evaluation tool based on microsimulation model

    Directory of Open Access Journals (Sweden)

    Tsavalista Burhani Jzolanda

    2017-01-01

    Full Text Available As port performance is becoming correlative to national competitiveness, the issue of port performance evaluation has significantly raised. Port performances can simply be indicated by port service levels to the ship (e.g., throughput, waiting for berthing etc., as well as the utilization level of equipment and facilities within a certain period. The performances evaluation then can be used as a tool to develop related policies for improving the port’s performance to be more effective and efficient. However, the evaluation is frequently conducted based on deterministic approach, which hardly captures the nature variations of port parameters. Therefore, this paper presents a stochastic microsimulation model for investigating the impacts of port parameter variations to the port performances. The variations are derived from actual data in order to provide more realistic results. The model is further developed using MATLAB and Simulink based on the queuing theory.

  16. Study of shielding options for lower ports for mitigation of neutron environment and shutdown dose inside the ITER cryostat

    International Nuclear Information System (INIS)

    Pampin, Raul; Suarez, Alejandro; Arnould, Anne; Casal, Natalia; Juarez, Rafael; Martin, Alex; Moro, Fabio; Mota, Fernando; Polunovskiy, Eduard; Sabourin, Flavien

    2016-01-01

    Highlights: • Mitigation of the radiation environment inside the cryostat needed to reduce ITER coil heating and occupational exposure. • Cryopump and diagnostics lower ports are significant contributors, shielding options for both are explored. • Shielding performance studied in terms of neutron transmission and nuclear heating to coils for a range of options. • Benefits/constraints discussed together with other engineering parameters. - Abstract: Mitigation of the neutron environment inside the cryostat, and of the subsequent decay gamma dose field from activated materials, is necessary in order to reduce heating of coils and occupational exposure, thereby facilitating smooth operation and maintenance of ITER. Several lines of action are currently being explored to mitigate crucial contributions, such as the leakage through the lower ports. Results are presented here for the two types of lower ports in ITER: cryopump ports and remote-handling ports. Different shielding configurations and material options are investigated and compared in terms of neutron attenuation, coil heating and shutdown dose rate reduction, whilst also considering other engineering constraints such as weight or pumping power. Results enable informed decision-making of best compromise solutions for subsequent design and integration.

  17. Study of shielding options for lower ports for mitigation of neutron environment and shutdown dose inside the ITER cryostat

    Energy Technology Data Exchange (ETDEWEB)

    Pampin, Raul, E-mail: raul.pampin@f4e.europa.eu [Fusion For Energy, Josep Pla 2, Barcelona 08019 (Spain); Suarez, Alejandro; Arnould, Anne; Casal, Natalia [ITER Organization, Route de Vinon sur Verdon, 13067 Saint Paul lez Durance Cedex (France); Juarez, Rafael [UNED, Juan del Rosal 12, Madrid 28040 (Spain); Martin, Alex [ITER Organization, Route de Vinon sur Verdon, 13067 Saint Paul lez Durance Cedex (France); Moro, Fabio [ENEA, Via Enrico Fermi, Frascati, Rome (Italy); Mota, Fernando [CIEMAT, Avenida Complutense 40, Madrid 28040 (Spain); Polunovskiy, Eduard; Sabourin, Flavien [ITER Organization, Route de Vinon sur Verdon, 13067 Saint Paul lez Durance Cedex (France)

    2016-11-01

    Highlights: • Mitigation of the radiation environment inside the cryostat needed to reduce ITER coil heating and occupational exposure. • Cryopump and diagnostics lower ports are significant contributors, shielding options for both are explored. • Shielding performance studied in terms of neutron transmission and nuclear heating to coils for a range of options. • Benefits/constraints discussed together with other engineering parameters. - Abstract: Mitigation of the neutron environment inside the cryostat, and of the subsequent decay gamma dose field from activated materials, is necessary in order to reduce heating of coils and occupational exposure, thereby facilitating smooth operation and maintenance of ITER. Several lines of action are currently being explored to mitigate crucial contributions, such as the leakage through the lower ports. Results are presented here for the two types of lower ports in ITER: cryopump ports and remote-handling ports. Different shielding configurations and material options are investigated and compared in terms of neutron attenuation, coil heating and shutdown dose rate reduction, whilst also considering other engineering constraints such as weight or pumping power. Results enable informed decision-making of best compromise solutions for subsequent design and integration.

  18. Prostate cancer in primary care, Port Harcourt, Nigeria

    Directory of Open Access Journals (Sweden)

    Andrew Bock-Oruma

    2014-01-01

    Full Text Available Context: Prostate cancer (PC is under-researched in primary care settings in the developing world, and diagnostic modalities available to the primary care physician could limit the making of the diagnosis, thus affecting the prevalence. Aims: This study aims to determine the prevalence of prostate cancer in patients that presented with LUTS to a family medicine clinic, using the screening tools (DRE and PSA available in the facility. Settings and Design: A cross-sectional study of middle-aged and elderly men that presented to the Family Medicine Clinic, University of Port Harcourt Teaching Hospital, Port Harcourt, Nigeria, with LUTS. Materials and Methods: Consenting and eligible males that presented to the Family Medicine Clinic with LUTS were assessed for prostate cancer using the PSA and digital rectal examination (DRE between October 2010 and April 2012. Data were entered and analyzed using the statistical package for the social sciences (SPSS version 16.0. Association between the variables was compared using chi-Square test with statistical significance set at P < 0.05. Results: Two hundred and ninety subjects participated in the study; the mean age of the subjects was 62.50 ± 11.66 years with an age range of 40 to 100 years. The prevalence for DRE-detected abnormal prostate was 13%, suggestive of PC. One hundred and sixty-one (55.5% of the subjects had their PSA done and results retrieved, with 51.6% of them having PSA values within the normal range of 0-4 ng/ml, and 48.4% had PSA values outside the normal limits. An association of PSA and DRE gave 24.2% prevalence for probable PC and a significant association between elevated PSA and DRE. Conclusion: The diagnostic modality in study is inconclusive, but it offers the family physician the opportunity of improving the quality of life of the patient that presented to him with PC by initiating early referral for secondary care.

  19. A three-port direct current converter

    DEFF Research Database (Denmark)

    2016-01-01

    circuit comprises a connection between the at least one input direct current source and the at least one storage battery, the primary side circuit configured for operating as a buck converter; a second magnetic component serially coupled to the first single magnetic component, wherein the first and second...... magnetic components are configured to perform a voltage step-up, wherein the secondary side circuit comprises a connection between the at least one storage battery and at least one load, the secondary side configured for operating as a tapped boost converter; wherein the three-port direct current converter......The three-port direct current converter comprising: at least one input direct current source; at least one storage battery; a primary side circuit; a secondary side circuit; a first single magnetic component shared by the primary side circuit and the secondary side circuit, wherein the primary side...

  20. United Kingdom Ireland coal ports directory

    Energy Technology Data Exchange (ETDEWEB)

    1992-01-01

    The directory gives details of ports at 65 locations in the UK and Ireland. For each port, the directory lists the name of the terminal; the name, address, contact name and numbers of the terminal owner and of the terminal operator; and the name and telephone/fax numbers of ship's agents. It also give details, for each terminal, where available, of tidal rise, access routes, vessel maxima, working hours, coal traders and handlers, discharge facilities, daily discharge rate, coal loading facilities, daily loading rate, stocking area dimensions and capacity, stocking area facilities and inland transport infrastructure. Research for the directory was undertaken by S. Fazal and C. Measham of Sheffield Hallam University, Business School.

  1. Major impact in shipping and port sectors

    Energy Technology Data Exchange (ETDEWEB)

    Cottrill, K.

    1985-08-01

    The impact of information technology (IT) on operations efficiency in the transport field is comparable to the revolution brought on by the use of containers. The author examines the influence of IT on British shipping in terms of documentation, cargo tracking, and trend analysis on the operational side and communications links on the structural side. Shipboard computers were slow to penetrate the traditional bastion of the ship's bridge, but the effects of automation are already evident in the size of crews and their work roles. Britain is a world leader in specialized networks in the ports sector. A European-based initiative for a European ports database is in the development stage. It is essential for the IT networks to be compatible both nationally and internationally for the technology to be worthwhile.

  2. Ethnopharmacology of Medicinal Plants in Genaveh Port

    Directory of Open Access Journals (Sweden)

    Leila Moradi

    2014-11-01

    Full Text Available Background: Ethnopharmacology has been seen as a multidisciplinatary approach for novel drug discovery by providing valuable data about medicinal plants in different cultures. The aim of this ethnopharmacological study was to identify medicinal plants of the Genaveh port in the North of Persian Gulf. Material and Methods: The medical uses of medicinal plants were gathered from 30 local informants by face to face interview. The relative frequency of citation (FRC and cultural importance (CI indices were calculated. Results: A total of 93 medicinal plants belonging to 55 families were identified. Plantago psyllium, Teucrium polium, Peganum harmala, Descuraninia sophia, Cichorium intybus, Achillea erophora DC, Matricarria charmomilla and Citrolus colocynthis had the highest cultural importance indices. Plantago psyllium, Descuraninia sophia and Zataria multiflora had the highest FRC indices. The highest medical uses were for gastrointestinal diseases, gynocological diseases, respiratory disorders, infectious diseases, nature of cool and metabolic disorders, respectively. In addition to the use of these plants to treat diseases as in Iran’s traditional medicine, people in the Genaveh port particularly use Plantago psyllium for drainage of infective boils and abscesses, cough, skin diseases, Teucrium polium for diabetes mellitus, wound washing and sterilizing, Peganum harmala for uterus infections and abdominal cramps, Descuraninia sophia for heart diseases and heatstroke, Cichorium intybus for heatstroke and liver diseases, Achillea eriophora DC for reflex, diabetes mellitus and wound healing, Matricarria charmomilla for seizure and dysmenorrhea, Citrolus colocynthis for hemorrhoid, diabetes mellitus and rheumatism and Zataria multiflora for sedation, abdominal pain and respiratory diseases. Conclusion: There is a vast variety of medicinal plants in Genaveh port. Although most of therapeutic applications of these plants in the Genaveh port are the

  3. Globalization and wine business: Port wine

    OpenAIRE

    Rebelo, Joao; Correia, Leonida; Caldas, Jose Vaz

    2007-01-01

    In the past two decades the world has seen acceleration in the process of globalisation, affecting virtually all industries and consumers. The wine sector is no exception, witnessing increased exports and imports, decreasing consumption per capita in the producing countries, and a wave of direct foreign investment and mergers and acquisitions in the industry. Among European wine producers the Port wine can be seen as a representative case of globalisation and as a benchmark, because almost 90...

  4. Laser Treatment of Port Wine Stains

    Science.gov (United States)

    Majaron, Boris; Nelson, J. Stuart

    Port wine stain (PWS), also called nevus flammeus, is a congenital, cutaneous vascular malformation involving post-capillary venules which produce a light pink to red to dark-red-violet discoloration of human skin [1]. PWS occurs in an estimated 3 children per 1000 live births, affecting males and females and all racial groups equally [2]. There appears to be no hereditary predilection for PWS within families. There are no known risk factors or ways to prevent PWS.

  5. 3D visualization of port simulation.

    Energy Technology Data Exchange (ETDEWEB)

    Horsthemke, W. H.; Macal, C. M.; Nevins, M. R.

    1999-06-14

    Affordable and realistic three dimensional visualization technology can be applied to large scale constructive simulations such as the port simulation model, PORTSIM. These visualization tools enhance the experienced planner's ability to form mental models of how seaport operations will unfold when the simulation model is implemented and executed. They also offer unique opportunities to train new planners not only in the use of the simulation model but on the layout and design of seaports. Simulation visualization capabilities are enhanced by borrowing from work on interface design, camera control, and data presentation. Using selective fidelity, the designers of these visualization systems can reduce their time and efforts by concentrating on those features which yield the most value for their simulation. Offering the user various observational tools allows the freedom to simply watch or engage in the simulation without getting lost. Identifying the underlying infrastructure or cargo items with labels can provide useful information at the risk of some visual clutter. The PortVis visualization expands the PORTSIM user base which can benefit from the results provided by this capability, especially in strategic planning, mission rehearsal, and training. Strategic planners will immediately reap the benefits of seeing the impact of increased throughput visually without keeping track of statistical data. Mission rehearsal and training users will have an effective training tool to supplement their operational training exercises which are limited in number because of their high costs. Having another effective training modality in this visualization system allows more training to take place and more personnel to gain an understanding of seaport operations. This simulation and visualization training can be accomplished at lower cost than would be possible for the operational training exercises alone. The application of PORTSIM and PortVis will lead to more efficient

  6. Managing Temporal Knowledge in Port Management Systems

    Directory of Open Access Journals (Sweden)

    Anita Gudelj

    2006-05-01

    Full Text Available Large ports need to deal with a number of disparate activities:the movement of ships, containers and other cargo, theloading and unloading of ships and containers, customs activities.As well as human resources, anchorages, channels, lighters,tugs, berths, warehouse and other storage spaces have to beallocated and released. The efficient management of a port involvesmanaging these activities and resources, managing theflows of money involved between the agents providing and usingthese resources, and providing management information.Many information systems will be involved.Many applications have to deal with a large amount of datawhich not only represent the perceived state of the real world atpresent, but also past and/or future states. These applicationsare not served adequately by today's computer managementand database systems. In particular, deletions and updates insuch systems have destructive semantics. This means that previousdatabase contents (representing previous perceived statesof the real world cannot be accessed anymore.A review of how define temporal data models, based ongeneralizing a non-temporal data model in to a temporal one toimprove port management is presented. This paper describes apractical experiment which supports managing temporal dataalong with the corresponding prototype implementations.

  7. Underwater Calibration of Dome Port Pressure Housings

    Science.gov (United States)

    Nocerino, E.; Menna, F.; Fassi, F.; Remondino, F.

    2016-03-01

    Underwater photogrammetry using consumer grade photographic equipment can be feasible for different applications, e.g. archaeology, biology, industrial inspections, etc. The use of a camera underwater can be very different from its terrestrial use due to the optical phenomena involved. The presence of the water and camera pressure housing in front of the camera act as additional optical elements. Spherical dome ports are difficult to manufacture and consequently expensive but at the same time they are the most useful for underwater photogrammetry as they keep the main geometric characteristics of the lens unchanged. Nevertheless, the manufacturing and alignment of dome port pressure housing components can be the source of unexpected changes of radial and decentring distortion, source of systematic errors that can influence the final 3D measurements. The paper provides a brief introduction of underwater optical phenomena involved in underwater photography, then presents the main differences between flat and dome ports to finally discuss the effect of manufacturing on 3D measurements in two case studies.

  8. A new system for port films.

    Science.gov (United States)

    Sephton, R; Green, M; Fitzpatrick, C

    1989-01-01

    A novel system for port films is described which incorporates a high-quality fluorescent screen lying behind a flat, heavy-metal screen or filter and the film pressed between them is not an X ray type but a single-emulsion, very high contrast graphics or line-type film. In experimental comparisons using 4 MV, 6 MV, and 25 MV photon beams, the new Peter MacCallum Cancer Institute (PMCI) system produced clearer images, about X2 higher in contrast yet lower in relative noise levels, than did the conventional commercially-available systems which use x-ray film between heavy-metal screens. Direct clinical comparisons, chiefly using 6 MV accelerators, confirmed that anatomical details were correspondingly better visualized and in general, the PMCI port film could be matched against the simulator radiograph with greater confidence. Routine use for greater than 2 yr in this Institute (4000 new patients per yr, 20 cassettes made for use with four 6 MV accelerators) has shown the PMCI system to be an economical and practical device, giving reproducibly high quality images in all the common port film applications.

  9. Unique problems of hydrocarbon contamination for ports

    International Nuclear Information System (INIS)

    Rice, D.W.

    1991-01-01

    Since the early 1900s, port facilities in the United States have been involved in the import and export of petroleum products. The WORLDPORT L.A. is a 7,000 acre land and water area that is administered by the Department of The City of Los Angeles under a tidelands grant from the State of California for the purposes of commerce, navigation, and fisheries. Over half of the oil-refining of California lies within 20 miles of WORLDPORT L.A. It is therefore not surprising that the port is a major hub for the handling of crude oil and petroleum products, including gasoline, aviation gas/jet fuel, and marine fuels. This paper reports that it is also not surprising that port facilities, given their long history of handling petroleum products, contain areas where soils and groundwater are contaminated with hydrocarbons. This contamination is localized but can be extensive. Petroleum and petrochemical products are handled at terminal facilities that are leased to oil companies

  10. Vectorization, parallelization and porting of nuclear codes (porting). Progress report fiscal 1999

    Energy Technology Data Exchange (ETDEWEB)

    Kawasaki, Nobuo; Nemoto, Toshiyuki; Kawai, Wataru; Ishizuki, Shigeru [Fujitsu Ltd., Tokyo (Japan); Ogasawara, Shinobu; Kume, Etsuo; Adachi, Masaaki [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment; Yatake, Yo-ichi [Hitachi Ltd., Tokyo (Japan)

    2001-01-01

    Several computer codes in the nuclear field have been vectorized, parallelized and transported on the FUJITSU VPP500 system, the AP3000 system, the SX-4 system and the Paragon system at Center for Promotion of Computational Science and Engineering in Japan Atomic Energy Research Institute. We dealt with 18 codes in fiscal 1999. These results are reported in 3 parts, i.e., the vectorization and the parallelization part on vector processors, the parallelization port on scalar processors and the porting part. In this report, we describe the porting. In this porting part, the porting of Assisted Model Building with Energy Refinement code version 5 (AMBER5), general purpose Monte Carlo codes far neutron and photon transport calculations based on continuous energy and multigroup methods (MVP/GMVP), automatic editing system for MCNP library code (autonj), neutron damage calculations for materials irradiations and neutron damage calculations for compounds code (SPECTER/SPECOMP), severe accident analysis code (MELCOR) and COolant Boiling in Rod Arrays, Two-Fluid code (COBRA-TF) on the VPP500 system and/or the AP3000 system are described. (author)

  11. Social Media Usage Patterns in Port Industry: Implications for Port Promotion and Public Relations

    Directory of Open Access Journals (Sweden)

    Aylin ÇALIŞKAN

    2018-03-01

    Full Text Available While social media has been penetrating the daily lives of individuals, the businesses have started to develop new strategical approaches for using social media tools, since they understand the importance of this new area. This study aims to take a step on the gap about social media marketing in the port industry. The focused sample is container ports located in Turkey, but to gain more meaningful insights, a comparison is also made with the ports of Los Angeles, Rotterdam, and Antwerp. The post set on Facebook, which covers the 8 months’ period, was analyzed through a social media analytics software, and the most attractive topics and engagement levels were determined. It was found that the most attractive posts of ports with high engagement levels do not include any statement, image, or video about port service, infrastructure and superstructure, investments, or success stories. At the end of the study, suggestions are developed by supporting with real cases for ports’ social media management.

  12. Nonvariceal upper gastrointestinal bleeding

    International Nuclear Information System (INIS)

    Burke, Stephen J.; Weldon, Derik; Sun, Shiliang; Golzarian, Jafar

    2007-01-01

    Nonvariceal upper gastrointestinal bleeding (NUGB) remains a major medical problem even after advances in medical therapy with gastric acid suppression and cyclooxygenase (COX-2) inhibitors. Although the incidence of upper gastrointestinal bleeding presenting to the emergency room has slightly decreased, similar decreases in overall mortality and rebleeding rate have not been experienced over the last few decades. Many causes of upper gastrointestinal bleeding have been identified and will be reviewed. Endoscopic, radiographic and angiographic modalities continue to form the basis of the diagnosis of upper gastrointestinal bleeding with new research in the field of CT angiography to diagnose gastrointestinal bleeding. Endoscopic and angiographic treatment modalities will be highlighted, emphasizing a multi-modality treatment plan for upper gastrointestinal bleeding. (orig.)

  13. Nonvariceal upper gastrointestinal bleeding

    Energy Technology Data Exchange (ETDEWEB)

    Burke, Stephen J.; Weldon, Derik; Sun, Shiliang [University of Iowa, Department of Radiology, Iowa, IA (United States); Golzarian, Jafar [University of Iowa, Department of Radiology, Iowa, IA (United States); University of Iowa, Department of Radiology, Carver College of Medicine, Iowa, IA (United States)

    2007-07-15

    Nonvariceal upper gastrointestinal bleeding (NUGB) remains a major medical problem even after advances in medical therapy with gastric acid suppression and cyclooxygenase (COX-2) inhibitors. Although the incidence of upper gastrointestinal bleeding presenting to the emergency room has slightly decreased, similar decreases in overall mortality and rebleeding rate have not been experienced over the last few decades. Many causes of upper gastrointestinal bleeding have been identified and will be reviewed. Endoscopic, radiographic and angiographic modalities continue to form the basis of the diagnosis of upper gastrointestinal bleeding with new research in the field of CT angiography to diagnose gastrointestinal bleeding. Endoscopic and angiographic treatment modalities will be highlighted, emphasizing a multi-modality treatment plan for upper gastrointestinal bleeding. (orig.)

  14. Six upper incisors: what's next?

    Science.gov (United States)

    Berneburg, Mirjam; Meller, Christian

    2016-01-01

    This case report describes our therapeutic approach taken in a girl with eruption disturbance of the upper anterior teeth. Two supernumerary teeth were involved, which required a combination of orthodontic and surgical treatment. The initial situation in the upper anterior segment was characterized by two supernumerary mesial incisors, ectopic eruption of the distally located lateral incisors, and crowded tooth buds in the canine areas. Key decisions had to be made as to whether any teeth needed to be extracted and, if so, regarding the timing and sites of extraction. Removing teeth too early would have preempted a complete assessment of tooth quality, whereas late extraction would have carried a risk of eruption disturbance. Once the distal lateral incisors had erupted, the supernumerary mesial incisors were extracted and the central incisors (initially located in between) mesialized with a bracket appliance. Following space closure and mesialization of the lateral incisors, a functional appliance was used. Tooth 13 was erupting, while tooth 23 was displaced and subsequently aligned as part of the final bracket treatment. To successfully treat eruption disturbances, a careful diagnostic workup is essential, including informative radiographs, personalized treatment planning, and correct decision-making as to whether teeth need to be extracted and regarding the timing and sites of extraction. Finally, the eruption of the canines should be monitored.

  15. Analyzer for gamma cameras diagnostic

    International Nuclear Information System (INIS)

    Oramas Polo, I.; Osorio Deliz, J. F.; Diaz Garcia, A.

    2013-01-01

    This research work was carried out to develop an analyzer for gamma cameras diagnostic. It is composed of an electronic system that includes hardware and software capabilities, and operates from the acquisition of the 4 head position signals of a gamma camera detector. The result is the spectrum of the energy delivered by nuclear radiation coming from the camera detector head. This system includes analog processing of position signals from the camera, digitization and the subsequent processing of the energy signal in a multichannel analyzer, sending data to a computer via a standard USB port and processing of data in a personal computer to obtain the final histogram. The circuits are composed of an analog processing board and a universal kit with micro controller and programmable gate array. (Author)

  16. An integrated port camera and display system for laparoscopy.

    Science.gov (United States)

    Terry, Benjamin S; Ruppert, Austin D; Steinhaus, Kristen R; Schoen, Jonathan A; Rentschler, Mark E

    2010-05-01

    In this paper, we built and tested the port camera, a novel, inexpensive, portable, and battery-powered laparoscopic tool that integrates the components of a vision system with a cannula port. This new device 1) minimizes the invasiveness of laparoscopic surgery by combining a camera port and tool port; 2) reduces the cost of laparoscopic vision systems by integrating an inexpensive CMOS sensor and LED light source; and 3) enhances laparoscopic surgical procedures by mechanically coupling the camera, tool port, and liquid crystal display (LCD) screen to provide an on-patient visual display. The port camera video system was compared to two laparoscopic video systems: a standard resolution unit from Karl Storz (model 22220130) and a high definition unit from Stryker (model 1188HD). Brightness, contrast, hue, colorfulness, and sharpness were compared. The port camera video is superior to the Storz scope and approximately equivalent to the Stryker scope. An ex vivo study was conducted to measure the operative performance of the port camera. The results suggest that simulated tissue identification and biopsy acquisition with the port camera is as efficient as with a traditional laparoscopic system. The port camera was successfully used by a laparoscopic surgeon for exploratory surgery and liver biopsy during a porcine surgery, demonstrating initial surgical feasibility.

  17. Radiologically-placed venous ports in children under venous anesthesia

    International Nuclear Information System (INIS)

    Jang, Joo Yeon; Jeon, Ung Bae; Choo, Ki Seok; Hwang, Jae Yeon; Kim, Yong Woo; Lee, Yun Jin; Nam, Sang Ool; Lim, Young Tak

    2015-01-01

    To evaluate the efficacy and safety of radiologic venous port placement in children under venous anesthesia. Between April 2009 and July 2011, 44 ports were implanted in 41 children (24 boys, 17 girls). The age of patients ranged from 9 months to 19 years (mean, 6.5 years) and their body weights ranged from 6.8 kg to 56.3 kg (mean, 23.2 kg). Right internal jugular vein access was used in 42 ports, right subclavian vein in 1, and left subclavian in 1. Durability and complications of port implantation were reviewed. The technical success rate was 100%. The catheter life was 10-661 days (mean 246 days). Two patients died during the follow-up period, 21 and 6 ports were removed at the end of treatment or as a result of complications, respectively. One port was removed and replaced by a Hickmann catheter. Three ports were explanted due to port-related sepsis, one due to a catheter kink, and two for unexplained fever or insertion site pain. The overall port-related infection was 3 cases (6.8%, 0.28/1000 catheter days). Venous port placement by interventional radiologists in children under intravenous sedation is relatively safe, with a high rate of technical success and low rate of complications.

  18. Assessing Port Governance, Devolution and Terminal Performance in Nigeria

    Directory of Open Access Journals (Sweden)

    D. E. Onwuegbuchunam

    2018-02-01

    Full Text Available Concerns about performance and efficiency in port terminals led many national governments to embark on port reforms. The Federal government of Nigeria, for example, adopted the Landlord port model which brought about concessioning of port terminals to private operators. Despite high investments in terminal facilities by the private terminal operators, there are still complaints about level of service offered to port users. This paper applied key performance indicator metrics and parameters of queuing model in assessing performance of Nigeria’s concessioned port terminals. Data for the study were obtained from terminal level records of cargo and ship handling activities for years 2000 to 2015. Major findings indicate that cargo and vessel throughputs improved after the reforms in the six ports examined. However, much variability was observed in trends in ships’ turnround times across all ports after the concession policy implementation. Additional results from the queuing model analysis suggest that the high ships turnround times observed in some ports are associated to delays in ship operation at the berths. The paper recommends that policy interventions be focused on ship operations at the berths as a step in improving service level in the port terminals.

  19. Radiologically-placed venous ports in children under venous anesthesia

    Energy Technology Data Exchange (ETDEWEB)

    Jang, Joo Yeon; Jeon, Ung Bae; Choo, Ki Seok; Hwang, Jae Yeon; Kim, Yong Woo; Lee, Yun Jin; Nam, Sang Ool; Lim, Young Tak [Pusan National University School of Medicine, Yangsan (Korea, Republic of)

    2015-02-15

    To evaluate the efficacy and safety of radiologic venous port placement in children under venous anesthesia. Between April 2009 and July 2011, 44 ports were implanted in 41 children (24 boys, 17 girls). The age of patients ranged from 9 months to 19 years (mean, 6.5 years) and their body weights ranged from 6.8 kg to 56.3 kg (mean, 23.2 kg). Right internal jugular vein access was used in 42 ports, right subclavian vein in 1, and left subclavian in 1. Durability and complications of port implantation were reviewed. The technical success rate was 100%. The catheter life was 10-661 days (mean 246 days). Two patients died during the follow-up period, 21 and 6 ports were removed at the end of treatment or as a result of complications, respectively. One port was removed and replaced by a Hickmann catheter. Three ports were explanted due to port-related sepsis, one due to a catheter kink, and two for unexplained fever or insertion site pain. The overall port-related infection was 3 cases (6.8%, 0.28/1000 catheter days). Venous port placement by interventional radiologists in children under intravenous sedation is relatively safe, with a high rate of technical success and low rate of complications.

  20. Ecological risk assessments for the baseline condition for the Port Hope and Port Granby Projects

    International Nuclear Information System (INIS)

    Hart, D.R.; Kleb, H.

    2006-01-01

    Baseline ecological risk assessments were completed in and around the areas where cleanup of low-level radioactive waste (LLRW) and marginally contaminated soil (MCS) is planned under the Port Hope Area Initiative (PHAI). Both aquatic and terrestrial environments were assessed, in the vicinity of the proposed waste management facilities near Welcome and Port Granby, in locations potentially influenced by LLRW and MCS that will be cleaned up in future, and in reference locations that are not potentially influenced. The calculated doses and risk quotients suggest potential radiation effects for pre-cleanup benthic invertebrates in Port Hope Harbour, for any ducks feeding exclusively in this area, and for soil invertebrates in some other waste sites. In addition, risk quotients suggest potential baseline effects from some elements, particularly uranium and arsenic, in localized areas that are influenced by LLRW and MCS. (author)

  1. Analysis of laparoscopic port site complications: A descriptive study

    Directory of Open Access Journals (Sweden)

    Somu Karthik

    2013-01-01

    Full Text Available Context: The rate of port site complications following conventional laparoscopic surgery is about 21 per 100,000 cases. It has shown a proportional rise with increase in the size of the port site incision and trocar. Although rare, complications that occur at the port site include infection, bleeding, and port site hernia. Aims: To determine the morbidity associated with ports at the site of their insertion in laparoscopic surgery and to identify risk factors for complications. Settings and Design: Prospective descriptive study. Materials and Methods: In the present descriptive study, a total of 570 patients who underwent laparoscopic surgeries for various ailments between August 2009 and July 2011 at our institute were observed for port site complications prospectively and the complications were reviewed. Statistical Analysis Used: Descriptive statistical analysis was carried out in the present study. The statistical software, namely, SPSS 15.0 was used for the analysis of the data. Results: Of the 570 patients undergoing laparoscopic surgery, 17 (3% had developed complications specifically related to the port site during a minimum follow-up of three months; port site infection (PSI was the most frequent (n = 10, 1.8%, followed by port site bleeding (n = 4, 0.7%, omentum-related complications (n = 2; 0.35%, and port site metastasis (n = 1, 0.175%. Conclusions: Laparoscopic surgeries are associated with minimal port site complications. Complications are related to the increased number of ports. Umbilical port involvement is the commonest. Most complications are manageable with minimal morbidity, and can be further minimized with meticulous surgical technique during entry and exit.

  2. Analysis of laparoscopic port site complications: A descriptive study

    Science.gov (United States)

    Karthik, Somu; Augustine, Alfred Joseph; Shibumon, Mundunadackal Madhavan; Pai, Manohar Varadaraya

    2013-01-01

    CONTEXT: The rate of port site complications following conventional laparoscopic surgery is about 21 per 100,000 cases. It has shown a proportional rise with increase in the size of the port site incision and trocar. Although rare, complications that occur at the port site include infection, bleeding, and port site hernia. AIMS: To determine the morbidity associated with ports at the site of their insertion in laparoscopic surgery and to identify risk factors for complications. SETTINGS AND DESIGN: Prospective descriptive study. MATERIALS AND METHODS: In the present descriptive study, a total of 570 patients who underwent laparoscopic surgeries for various ailments between August 2009 and July 2011 at our institute were observed for port site complications prospectively and the complications were reviewed. STATISTICAL ANALYSIS USED: Descriptive statistical analysis was carried out in the present study. The statistical software, namely, SPSS 15.0 was used for the analysis of the data. RESULTS: Of the 570 patients undergoing laparoscopic surgery, 17 (3%) had developed complications specifically related to the port site during a minimum follow-up of three months; port site infection (PSI) was the most frequent (n = 10, 1.8%), followed by port site bleeding (n = 4, 0.7%), omentum-related complications (n = 2; 0.35%), and port site metastasis (n = 1, 0.175%). CONCLUSIONS: Laparoscopic surgeries are associated with minimal port site complications. Complications are related to the increased number of ports. Umbilical port involvement is the commonest. Most complications are manageable with minimal morbidity, and can be further minimized with meticulous surgical technique during entry and exit. PMID:23741110

  3. EVALUATING THE COMPETITION DYNAMICS OF CONTAINER PORTS IN THE NORTH ADRIATIC

    OpenAIRE

    Twrdy, Elen; Batista, Milan

    2014-01-01

    World trade has changed in the last decade and the container traffic flows are oriented towards several parts of the European continent. A European container port system is not a homogenous set of ports, but is established of several large ports (Rotterdam, Hamburg, Algeciras...) and a large number of medium- and small-sized ports. North Adriatic (NA) ports belong to this category of ports and in this paper we have analysed the container flows and the throughput attained in these ports.

  4. An analysis of the development of port operation in Da Nang Port, Vietnam

    Science.gov (United States)

    Nguyen, T. D. H.; Cools, M.

    2018-04-01

    This paper presents the current operating status in Da Nang Port, Vietnam in the period 2012-2016. The port operation had positive changes that were reflected by a significant increase in total throughputs, especially containerized cargo volumes. Classical decomposition techniques are used to find trend-cycle and seasonal components of monthly throughput flows. Appropriate predictive models of different kinds of throughputs are proposed. Finally, a development strategy towards containerization and investment policies in facilities, equipment, and infrastructure are suggested based on the predictive results.

  5. Ports, policies and interventions in ports in Portugal - 20th Century

    OpenAIRE

    Dias, Emílio Brògueira; Alves, Jorge Fernandes

    2010-01-01

    Ce texte, inspiré des données issues des travaux des deux auteurs, aborde, de manière synthétique, les grandes lignes des transformations portuaires au Portugal, à travers un panorama des différents ports et de leur évolution. Cet exposé se focalise sur les exemples les plus significatifs que sont les ports de Leixões, Aveiro, Lisbonne, Setubal et Sines. This text, based on the data used in previous works by the authors, seeks to assess briefly, the main lines of transformations in Portuga...

  6. The effectiveness of single port thoracoscopic approach in pleural effusions

    Directory of Open Access Journals (Sweden)

    Yasemin Bilgin Büyükkarabacak

    2014-12-01

    Full Text Available Objective: Currently, thoracoscopic procedures have been used frequently in diagnosis and treatment of pleural effusions. It was reported, high diagnosis and treatment success with thoracoscopy in pleural effusion, which was not, diagnosed using cytology and blinding pleural biopsy procedures. In this study, it was aimed to evaluate of the patient was performed video-assisted thoracic surgery (VATS due to pleural effusion. Methods: Between 2011 and 2014 years, it was evaluated 52 patients was performed VATS because of pleural effusion. The procedure was performed under general anesthesia and single lung ventilation in 50 patients, and local anesthesia in 2 patients. Results: Histopathological results were reported as carcinoma infiltration in 29 patients, benign disease in 23 patients. Cytological examination of liquid was executed before thoracoscopy in all of the patients with malignity positive. In addition, in eight patients pleura biopsy, on which blinding was executed, evaluated as malignity negative. The diagnostic value of our procedure has 100% in malign group and 98% in benign group. In patients with malignant disease, pleurodesis was performed peroperatively. Mean hospital stay was 5 days (3-15. Mean duration of terminating chest tube was 3 days (3-15. There were no morbidity and mortality due to procedure. Conclusion: Single port VATS is an effective and safe procedure in diagnosis and palliative treatment of patient with pleural effusion, and it has high success rate and reduces hospital stay.

  7. Analyzing Growth Opportunity of Port from the Resource-based Perspective The Case of Port of Tanjung Pelepas Malaysia

    Directory of Open Access Journals (Sweden)

    Muhammad Subhan

    2008-09-01

    Full Text Available Capturing growth opportunity has become a major integral activity of any port to sustain growth and competitive advantage. One of the famous strategies in leveraging sustainable growth and competitive advantage is the resource-based theory application into port strategic management, viewing resources of the port (internal and external and its capabilities as the sources for achieving competitive advantage. In this study, we attempt to identify, exploit, and analyze growth opportunity of a Malaysian port from the perspective of the theory. We analyze the port’s resources in terms of values, uniqueness, inimitability, durability, and substitutability. The result is then compared with its rival ports in the region. This study recognizes that the port has successfully identified and exploited its resources for capturing growth opportunity and competing with other ports in the region. We perceive that the port will sustain its growth and competitive advantage as a major port in the region based on its current performance and rivalry circumstances. This study signifies that the higher the level to which resource-based theory of competitive advantage is applied, the higher and longer the growth and competitive advantage will be achieved by the port.

  8. FNR demonstration experiments Part I: Beam port leakage currents and spectra

    International Nuclear Information System (INIS)

    Wehe, D.K.; King, J.S.

    1983-01-01

    , unexpected changes in A-port beam geometry occurred. As a consequence G-port data is somewhat suspect, and A-port data was available for only part of the experiments. Second, the initial conversion to the LEU core was sufficiently unpredictable in reactivity that fuel element additions were necessary during the initial LEU experiments. As a consequence three LEU cores of slightly different loading geometry are reported herein. The major difference in these cores, as is evident in the figures, was a shift from east to west in the core loading pattern. This had a considerable effect, apparently, in shifting the beam port leakage pattern, is discussed. Third, the D 2 0 tank has presented several special problems. Access to the volume of the tank is very limited; it is possible to reach only the upper region of the tank, the deepest penetration being 5 in below the core fuel top level for the SPND detector and, for wire activations. This requires a large extrapolation from a position of maximum flux gradient to predict data equivalent to core midplane. In addition there is now evidence that the rhodium SPND response in the D 2 O tank does not agree with either Fe or Rh wire activations when all three measurements are normalized to measurements at the same point at the center of the core

  9. Catheter fracture of intravenous ports and its management.

    Science.gov (United States)

    Wu, Ching-Yang; Fu, Jui-Ying; Feng, Po-Hao; Kao, Tsung-Chi; Yu, Sheng-Yueh; Li, Hao-Jui; Ko, Po-Jen; Hsieh, Hung-Chang

    2011-11-01

    Intravenous ports are widely used for oncology patients. However, catheter fractures may lead to the need for re-intervention. We aimed to identify the risk factors associated with catheter fractures. Between January 1 and December 31, 2006, we retrospectively reviewed the clinical data and plain chest films of 1,505 patients implanted with an intravenous port at Chang Gung Memorial Hospital. Different vascular sites were compared using the chi-square or Fisher's exact test for categorical variables, and the t test was used for continuous variables with normal distribution; P port type Arrow French (Fr.) 8.1 (P port and catheter removal is recommended. Female gender, intravenous port implantation via the subclavian route, and the Arrow Fr. 8.1 port were found to be risk factors. Patients with these risk factors should be monitored closely to avoid catheter fractures.

  10. Risk mitigation strategy for the ITER electron cyclotron upper port launcher

    NARCIS (Netherlands)

    Goede, A. P. H.; Bongers, W. A.; Elzendoorn, B. S. Q.; M. F. Graswinckel,; M.R. de Baar,

    2010-01-01

    A basic requirement for ITER equipment to meet is a high level of reliability, because ITER operation time is precious and radioactive operation leaves limited scope for repair. In order to reduce the risk of failure during ITER operation an effective risk mitigation strategy is necessary. This

  11. Maintenance implications of critical components in ITER CXRS upper port plug design

    NARCIS (Netherlands)

    Koning, J.; Jaspers, R.; Doornink, J.; Ouwehand, B.; Klinkhamer, J.F.F.; Snijders, B.; Sadakov, S.; Heemskerk, C.

    2009-01-01

    Already in the early phase of a design for ITER, the maintenance aspects should be taken into account, since they might have serious implications. This paper presents the arguments in support of the case for the maintainability of the design, notably if this maintenance is to be performed by

  12. Analysis of the ITER ECH Upper Port Launcher remote maintenance using virtual reality

    NARCIS (Netherlands)

    Elzendoorn, B.; Baar, M. de; Chavan, R.; Goodman, T.; Heemskerk, C.; Heidinger, R.; Kleefeldt, K.; Koning, J.; Sanders, S.; Späh, P.; Strauss, D.; Verhoeven, T.; Vreede, F. de

    2009-01-01

    All ITER sub-systems of remote handling (RH) classes 1 and 2 have to be remotely maintainable. The maintenance strategy for these components has to ensure system availability after failure or scheduled maintenance. This paper shows how virtual reality (VR) simulation [1] can be used as a tool to

  13. Upper respiratory tract (image)

    Science.gov (United States)

    The major passages and structures of the upper respiratory tract include the nose or nostrils, nasal cavity, mouth, throat (pharynx), and voice box (larynx). The respiratory system is lined with a mucous membrane that ...

  14. ACA Federal Upper Limits

    Data.gov (United States)

    U.S. Department of Health & Human Services — Affordable Care Act Federal Upper Limits (FUL) based on the weighted average of the most recently reported monthly average manufacturer price (AMP) for...

  15. Umbilical KeyPort bilateral laparoscopic orchiectomy in patient with complete androgen insensitivity syndrome

    Directory of Open Access Journals (Sweden)

    Felipe P. Andrade

    2012-10-01

    Full Text Available MAIN FINDINGS: A 22-year-old woman with complete androgen insensitivity syndrome (CAIS presenting with primary amenorrhea and normal female external genitalia was referred for laparoscopic gonadectomy. She had been diagnosed several years earlier but was reluctant to undergo surgery. CASE HYPOTHESIS: Diagnosis of this X-linked recessive inherited syndrome characterizes by disturbance of virilization in males with an AR mutation, XY karyotipe, female genitalia and severely undescended testis with risk of malignization. The optimal time to orchidectomy is not settled; neither the real risk of malignancy in these patients. Early surgery impacts development of a complete female phenotype, with enlargement of the breasts. Based on modern diagnostic imaging using DCE-MRI and surgical technology with single port laparoscopic access we hypothesize that the optimum time for gonadectomy is not at the time of diagnosis, but once feminization has completed. PROMISING FUTURE IMPLICATIONS: An umbilical laparoendoscopic single-site access for bilateral gonadectomy appears to be the first choice approach as leaves no visible incision and diminishes the psychological impact of surgery in a patient with CAIS absolutely reassured as female. KeyPort, a single port access with duo-rotate instruments developed by Richard Wolf facilitates this surgery and allows excellent cosmetic results.

  16. Diagnosis and management of upper gastrointestinal bleeding in children.

    Science.gov (United States)

    Owensby, Susan; Taylor, Kellee; Wilkins, Thad

    2015-01-01

    Upper gastrointestinal bleeding is an uncommon but potentially serious, life-threatening condition in children. Rapid assessment, stabilization, and resuscitation should precede all diagnostic modalities in unstable children. The diagnostic approach includes history, examination, laboratory evaluation, endoscopic procedures, and imaging studies. The clinician needs to determine carefully whether any blood or possible blood reported by a child or adult represents true upper gastrointestinal bleeding because most children with true upper gastrointestinal bleeding require admission to a pediatric intensive care unit. After the diagnosis is established, the physician should start a proton pump inhibitor or histamine 2 receptor antagonist in children with upper gastrointestinal bleeding. Consideration should also be given to the initiation of vasoactive drugs in all children in whom variceal bleeding is suspected. An endoscopy should be performed once the child is hemodynamically stable. © Copyright 2015 by the American Board of Family Medicine.

  17. Thyroid diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Scriba, P C; Boerner, W; Emrich, S; Gutekunst, R; Herrmann, J; Horn, K; Klett, M; Krueskemper, H L; Pfannenstiel, P; Pickardt, C R

    1985-03-01

    None of the in-vitro and in-vivo methods listed permits on unambiguous diagnosis when applied alone, owing to the fact that similar or even identical findings are obtained for various individual parameters in different thyroid diseases. Further, especially the in-vitro tests are also subject to extrathyroidal effects which may mask the typical findings. The limited and varying specificity and sensitivity of the tests applied, as well as the falsification of results caused by the patients' idiosyncracies and the methodology, make it necessary to interpret and evaluate the in-vivo and in-vitro findings only if the clinical situation (anamnesis and physical examination) is known. For maximum diagnostic quality of the tests, the initial probability of the assumed type of thyroid disease must be increased (formulation of the clinical problem). The concepts of exclusion diagnosis and identification must be distinguished as well as the diagnosis of functional disturbances on the one hand and of thyroid diseases on the other. Both of this requires a qualified, specific and detailed anamnesis and examination procedure, and the clinical examination remains the obligatory basis of clinical diagnostics. In case of inexplicable discrepancies between the clinical manifestations and the findings obtained with specific methods, or between the findings obtained with a specific method, the patient should be referred to an expert institution, or the expert institution should be consulted.

  18. Thyroid diagnostics

    International Nuclear Information System (INIS)

    Scriba, P.C.; Boerner, W.; Emrich, S.; Gutekunst, R.; Herrmann, J.; Horn, K.; Klett, M.; Krueskemper, H.L.; Pfannenstiel, P.; Pickardt, C.R.; Reiners, C.; Reinwein, D.; Schleusener, H.

    1985-01-01

    None of the in-vitro and in-vivo methods listed permits on unambiguous diagnosis when applied alone, owing to the fact that similar or even identical findings are obtained for various individual parameters in different thyroid diseases. Further, especially the in-vitro tests are also subject to extrathyroidal effects which may mask the typical findings. The limited and varying specificity and sensitivity of the tests applied, as well as the falsification of results caused by the patients' idiosyncracies and the methodology, make it necessary to interpret and evaluate the in-vivo and in-vitro findings only if the clinical situation (anamnesis and physical examination) is known. For maximum diagnostic quality of the tests, the initial probability of the assumed type of thyroid disease must be increased (formulation of the clinical problem). The concepts of exclusion diagnosis and identification must be distinguished as well as the diagnosis of functional disturbances on the one hand and of thyroid diseases on the other. Both of this requires a qualified, specific and detailed anamnesis and examination procedure, and the clinical examination remains the obligatory basis of clinical diagnostics. In case of inexplicable discrepancies between the clinical manifestations and the findings obtained with specific methods, or between the findings obtained with a specific method, the patient should be referred to an expert institution, or the expert institution should be consulted. (orig./MG) [de

  19. Ambient diagnostics

    CERN Document Server

    Cai, Yang

    2014-01-01

    Part I. FundamentalsIntroductionWhat is Ambient Diagnostics?Diagnostic ModelsMultimedia IntelligenceCrowd SourcingSoft SensorsScience of SimplicityPersonal DiagnosesBasic AlgorithmsBasic ToolsSummaryProblemsTransformationEarly Discoveries of Heartbeat PatternsTransforms, Features, and AttributesSequential FeaturesSpatiotemporal FeaturesShape FeaturesImagery FeaturesFrequency Domain FeaturesMulti-Resolution FeaturesSummaryProblemsPattern RecognitionSimilarities and DistancesClustering MethodsClassification MethodsClassifier Accuracy MeasuresSummaryProblemsPart II. Multimedia IntelligenceSound RecognitionMicrophone AppsModern Acoustic Transducers (Microphones)Frequency Response CharacteristicsDigital Audio File FormatsHeart Sound SensingLung Sound SensingSnore MeterSpectrogram (STFT)Ambient Sound AnalysisSound RecognitionRecognizing Asthma SoundPeak ShiftFeature CompressionRegroupingNoise IssuesFuture ApplicationsSummaryProblemsColor SensorsColor SensingHuman Color VisionColor SensorsColor Matching ExperimentsC...

  20. Upper gastrointestinal bleeding.

    Science.gov (United States)

    Feinman, Marcie; Haut, Elliott R

    2014-02-01

    Upper gastrointestinal (GI) bleeding remains a commonly encountered diagnosis for acute care surgeons. Initial stabilization and resuscitation of patients is imperative. Stable patients can have initiation of medical therapy and localization of the bleeding, whereas persistently unstable patients require emergent endoscopic or operative intervention. Minimally invasive techniques have surpassed surgery as the treatment of choice for most upper GI bleeding. Copyright © 2014 Elsevier Inc. All rights reserved.

  1. Repair of traumatic tricuspid insufficiency via minimally invasive port access.

    Science.gov (United States)

    Kasahara, Hirofumi; Kudo, Mikihiko; Kawajiri, Hiroyuki; Yozu, Ryohei

    2010-04-01

    We report on a successful tricuspid valve plasty using port-access minimally invasive cardiac surgery (MICS) for severe traumatic tricuspid insufficiency caused by blunt chest trauma suffered 15 years previously. A combination repair procedure, consisting of cleft closures, plication of the anteroseptal commissure, and ring annuloplasty, was necessary to achieve valve competence and proved possible via port access without difficulty. Port-access MICS is an alternative approach for tricuspid valve surgery.

  2. A Mixed Integer Programming for Port Anzali Development Plan

    OpenAIRE

    Mahdieh Allahviranloo

    2009-01-01

    This paper introduces a mixed integer programming model to find the optimum development plan for port Anzali. The model minimizes total system costs taking into account both port infrastructure costs and shipping costs. Due to the multipurpose function of the port, the model consists of 1020 decision variables and 2490 constraints. Results of the model determine the optimum number of berths that should be constructed in each period and for each type of cargo. In addition to, the results of se...

  3. Intracorporeal hybrid single port vs conventional laparoscopic appendectomy in children

    Directory of Open Access Journals (Sweden)

    Paul Anthony Karam

    2016-12-01

    Full Text Available Transumbilical laparoscopic assisted appendectomy combines laparoscopic single port dissection with open appendectomy after exteriorization of the appendix through the port site. Compared to the conventional three-port approach, this technique provides an alternative with excellent cosmetic outcome. We developed a safe and effective technique to perform an intracorporeal single port appendectomy, using the same laparoscope employed in the extracorporeal procedure. Retrospective review of 71 consecutively performed intracorporeal single port appendectomies and 30 conventional three-port appendectomies in children 6 to 17 years of age. A straight 10-mm Storz telescope with inbuilt 6 mm working channel is used to dissect the appendix, combined with one port-less 2.3 mm percutaneous grasper. Polymer WECK® hem-o-lock® clips are applied to seal the base of the appendix and the appendiceal vessels. No intraoperative complications were reported with the hybrid intracorporeal single port appendectomy or three-port appendectomy. There were two post-operative complications in the group treated with the single port hybrid technique: one intra-abdominal abscess and one surgical site infection. Groups did not differ in age, weight, and types of appendicitis. Operative times were shorter for the hybrid technique (70 vs 79 minutes but did not differ significantly (P=0.19. This modified technique to a previously described single port extracorporeal appendectomy is easy to master and implement. It provides exposure similar to a three-port laparoscopic appendectomy, while maintaining virtually scarless results and potentially reduces the risk for surgical site infections compared to the extracorporeal technique.

  4. Irrigation port hydration in phacoemulsification surgery

    Directory of Open Access Journals (Sweden)

    Suzuki H

    2018-01-01

    Full Text Available Hisaharu Suzuki,1 Yoichiro Masuda,2 Yuki Hamajima,1 Hiroshi Takahashi3 1Department of Ophthalmology, Nippon Medical School Musashikosugi Hospital, Kawasaki City, Kanagawa, 2Department of Ophthalmology, The Jikei University, Katsushika Medical Center, Tokyo, 3Department of Ophthalmology, Nippon Medical School, Tokyo, Japan Background: In most cases, hydration is performed by water injection into the stromal tissue with a needle. The technique is simple, however it is sometimes troublesome.Purpose: We describe a simple technique for hydrating the corneal stroma in cataract surgery using an irrigation port.Patients and methods: The technique began by pushing the irrigation port against the corneal stroma for a few seconds during phacoemulsification, which generated edema in the corneal incision that subsequently prevented leakage. This procedure is called the hydration using irrigation port (HYUIP technique. A total of 60 eyes were randomized and placed in two groups, 30 eyes underwent surgeries using the HYUIP technique (HYUIP group and 30 eyes underwent surgeries without the HYUIP technique (control. The three points evaluated during each surgery included 1 the occurrence of anterior chamber collapse during the pulling out of the I/A tip after inserting the intraocular lens, 2 the need for conventional hydration, and 3 watertight completion at the end stage of surgery.Results: The anterior chamber collapse and the need for conventional hydration were significantly smaller in the HYUIP group compared to the control group. Regarding the self-sealing completion, no significant difference was observed between the two groups.Conclusion: The HYUIP technique is an effective method for creating self-sealing wound. In addition, this technique helps to prevent anterior chamber collapse. Keywords: cataract surgery, hydration, irrigation and aspiration, phacoemulsification, wound, self-sealing 

  5. Single-port unilateral transaxillary totally endoscopic thyroidectomy: A survival animal and cadaver feasibility study

    Directory of Open Access Journals (Sweden)

    Henrique Neubarth Phillips

    2016-01-01

    Full Text Available Background: Single-port unilateral axillary thyroidectomy has great potential to become a valid alternative technique for thyroid surgery. We tested the technique in a study on live animals and cadavers to evaluate the feasibility and reproducibility of the procedure. Materials and Methods: Institutional review board (IRB approval was obtained in our university by the Council of Ethics for the study in surviving animals and cadavers. Subtotal thyroidectomy using unilateral axillary single port was performed in five dogs and five cadavers. Performing incision in the axillary fossa, a disposable single port was inserted. The dissection progressed for creating a subcutaneous tunnel to the subplatysmal region; after opening the platysma muscle and separation of the strap muscles, the thyroid gland was identified. After key anatomical landmarks were identified, the dissection was started at the upper pole towards the bottom, and to the isthmus. Specimens were extracted intact through the tunnel. Clinical and laboratorial observations of the experimental study in a 15-day follow-up and intraoperative data were documented. Results: All surgeries were performed in five animals which survived 15 days without postoperative complications. In the surgeries successfully performed in five cadavers, anatomical landmarks were recognised and intraoperative dissection of recurrent nerves and parathyroid glands was performed. Mean operative time was 64 min (46-85 min in animals and 123 min (110-140 min in cadavers, with a good cosmetic outcome since the incision was situated in the axillary fold. Conclusion: The technique of single-port axillary unilateral thyroidectomy was feasible and reproducible in the cadavers and animal survival study, suggesting the procedure as an alternative to minimally invasive surgery of the neck.

  6. Port and EGR Mass Flow Sensors

    DEFF Research Database (Denmark)

    Hendricks, Elbert

    1998-01-01

    The note documents briefly work done on what is thought to be a new method of measurement of the pulsating flow in the intake port ot and SI engine and in the EGR returen line. The work reviewed has been carried out in close cooperation with Civ. Ing. Michael Føns, Civ. Ing. Christian Jepsen, the......, the author (IAU) and Spencer C. Sorenson (ET). The theory which decribes in detail the overall dynamic chracteristics of the sensor was developed at IAU and ET, DTU....

  7. Compressor ported shroud for foil bearing cooling

    Science.gov (United States)

    Elpern, David G [Los Angeles, CA; McCabe, Niall [Torrance, CA; Gee, Mark [South Pasadena, CA

    2011-08-02

    A compressor ported shroud takes compressed air from the shroud of the compressor before it is completely compressed and delivers it to foil bearings. The compressed air has a lower pressure and temperature than compressed outlet air. The lower temperature of the air means that less air needs to be bled off from the compressor to cool the foil bearings. This increases the overall system efficiency due to the reduced mass flow requirements of the lower temperature air. By taking the air at a lower pressure, less work is lost compressing the bearing cooling air.

  8. Three port converters used as interface in photovoltaic energy systems

    Directory of Open Access Journals (Sweden)

    Sarab Al-Chlaihawi

    2018-04-01

    Full Text Available The aim of this paper is to derive and study a full-bridge three-port converter. Based on the standard design of full-bridge converter, we have modeled and derived a three port converter. The three port converter can be used in renewable energy scenarios, such as solar cells or wind turbines connected to the input port. The input can be taken from two-ports simultaneously or from one port at a time. In order to balance the power mismatch between the input port and load port, the batteries are attached to the third port, to ensure there are no discrepancies in the power generated at the input and power demand at the load. In order to ensure isolation and reduced voltage stress on the switches, a high frequency transformer is also used in the design. The overall design contains four switches, and four diodes. MOSFETs are the strongest candidate for the switches owing to their high switching speed, lower losses and high resistance to higher voltage. Moreover, a buck-boost structure is modeled in order to ensure that it can work for a wide variety of different applications by adjusting the duty cycle of the switches properly. To minimize the switching losses in the converter, Zero-Voltage Switching (ZVS is also achievable in the modeled system.

  9. Soil contamination issues at U.S. ports

    International Nuclear Information System (INIS)

    Rice, D.W.; Hagner, D.

    1991-01-01

    This paper reports that seven large and medium size west coast ports were surveyed during August 1990 to determine their involvement with hydrocarbon contaminated soils and activities associated with the characterization and remediation of these soils. All ports surveyed indicated that hey have hydrocarbon contaminated soil problems. Although other west coast ports do not have the scale of petroleum transfer and storage facilities that the Prot of Los Angeles has, all ports had tenants with bulk oil or fuel storage in aboveground tanks and were undertaking characterization and remediation work. Hydrocarbon contaminated soil problems were associated with these facilities or with decommissioned facilities of this type

  10. The Aggregate Planning For Trucking Operation in Cikarang Dry Port

    Directory of Open Access Journals (Sweden)

    Dwi Puspita Sari Utami

    2015-06-01

    Full Text Available Abstract. Cikarang Dry Port currently is the only dry port in Indonesia. This Dry Port has a role to connect or extend the Sea Port to the industrial areas located far from Sea Port. Thus, it creates a value added and also reduce costs. One of the operations done in Cikarang Dry Port is trucking operation. This research aims to examine the planning of 2014 trucking activity in Cikarang Dry Port to determine the right number of the truck that will be best occupied to manage all demands. The analysis begins with demand forecasting by using a moving average method of 12 months or one year period in 2013 which will be used as main information to develop the plans. There are three plans developed in this research. Based on the three plans, Plan A with minimum trucking plan with subcontracting is the most profitable which gives the highest profitability of Rp. 374,984,625. Recommendation for this research is using the current minimum number of 39 trucks rent with additional subcontracting when the demand is exceeding the capacity, thus, Cikarang Dry Port can occupy all demands and gain more profits. Keywords: Aggregate Planning; Scheduling; Trucking Operation; Moving Average; Cikarang Dry Port

  11. The Aggregate Planning For Trucking Operation in Cikarang Dry Port

    Directory of Open Access Journals (Sweden)

    Dwi Puspita Sari Utami

    2015-07-01

    Full Text Available Abstract. Cikarang Dry Port currently is the only dry port in Indonesia. This Dry Port has a role to connect or extend the Sea Port to the industrial areas located far from Sea Port. Thus, it creates a value added and also reduce costs. One of the operations done in Cikarang Dry Port is trucking operation. This research aims to examine the planning of 2014 trucking activity in Cikarang Dry Port to determine the right number of the truck that will be best occupied to manage all demands. The analysis begins with demand forecasting by using a moving average method of 12 months or one year period in 2013 which will be used as main information to develop the plans. There are three plans developed in this research. Based on the three plans, Plan A with minimum trucking plan with subcontracting is the most profitable which gives the highest profitability of Rp. 374,984,625. Recommendation for this research is using the current minimum number of 39 trucks rent with additional subcontracting when the demand is exceeding the capacity, thus, Cikarang Dry Port can occupy all demands and gain more profits.Keywords: Aggregate Planning; Scheduling; Trucking Operation; Moving Average; Cikarang Dry Port

  12. Development of the alternate entry port for the ATF

    International Nuclear Information System (INIS)

    Parsa, Z.

    1993-05-01

    We discussed a second entry port for the Accelerator Test Facility (ATF) injection system at Brookhaven National Laboratory, which consists of a photocathode rf gun and a straight - ahead beamline directly into the 50 MeV linac. The proposed second entry port should improve the beam quality and lower the emittance needed for FEL (Free Electron Laser), and laser - acceleration experiments. A discussion on the laser driven high brightness photoelectrons through the primary entry port (a low energy 180 degrees achromatic double bend transport line) now in operation, and a beam analysis for the proposed secondary port is also given

  13. Upper GI Bleeding in Children

    Science.gov (United States)

    Upper GI Bleeding in Children What is upper GI Bleeding? Irritation and ulcers of the lining of the esophagus, stomach or duodenum can result in upper GI bleeding. When this occurs the child may vomit blood ...

  14. Vectorization, parallelization and porting of nuclear codes (porting). Progress report fiscal 1998

    International Nuclear Information System (INIS)

    Nemoto, Toshiyuki; Kawai, Wataru; Ishizuki, Shigeru; Kawasaki, Nobuo; Kume, Etsuo; Adachi, Masaaki; Ogasawara, Shinobu

    2000-03-01

    Several computer codes in the nuclear field have been vectorized, parallelized and transported on the FUJITSU VPP500 system, the AP3000 system and the Paragon system at Center for Promotion of Computational Science and Engineering in Japan Atomic Energy Research Institute. We dealt with 12 codes in fiscal 1998. These results are reported in 3 parts, i.e., the vectorization and parallelization on vector processors part, the parallelization on scalar processors part and the porting part. In this report, we describe the porting. In this porting part, the porting of Monte Carlo N-Particle Transport code MCNP4B2 and Reactor Safety Analysis code RELAP5 on the AP3000 are described. In the vectorization and parallelization on vector processors part, the vectorization of General Tokamak Circuit Simulation Program code GTCSP, the vectorization and parallelization of Molecular Dynamics Ntv Simulation code MSP2, Eddy Current Analysis code EDDYCAL, Thermal Analysis Code for Test of Passive Cooling System by HENDEL T2 code THANPACST2 and MHD Equilibrium code SELENEJ on the VPP500 are described. In the parallelization on scalar processors part, the parallelization of Monte Carlo N-Particle Transport code MCNP4B2, Plasma Hydrodynamics code using Cubic Interpolated propagation Method PHCIP and Vectorized Monte Carlo code (continuous energy model/multi-group model) MVP/GMVP on the Paragon are described. (author)

  15. Optimisation of ported yield of hemispherical ported microparticles for soft tissue augmentation

    CSIR Research Space (South Africa)

    Barnard, A

    2011-05-01

    Full Text Available degradation period and biocompatibility. Micro-porous particles are useful in soft-tissue bulking due to their relatively large surface area, low density and high degree of porosity. In this study, the authors have developed ported porous PCL particles...

  16. Diagnostic accuracy of organ electrodermal diagnostics | Szopinski ...

    African Journals Online (AJOL)

    Objective. To estimate the diagnostic accuracy as well as the scope of utilisation of a new bio-electronic method of organ diagnostics. Design. Double-blind comparative study of the diagnostic results obtained by means of organ electrodermal diagnostics (OED) and clinical diagnoses, as a criterion standard. Setting.

  17. Analyzing Growth Opportunity of Port from the Resource-based Perspective The Case of Port of Tanjung Pelepas Malaysia

    OpenAIRE

    Subhan, Muhammad; Abdul Ghani, Ahmad Bashawir

    2008-01-01

    Capturing growth opportunity has become a major integral activity of any port to sustain growth and competitive advantage. One of the famous strategies in leveraging sustainable growth and competitive advantage is the resource-based theory application into port strategic management, viewing resources of the port (internal and external) and its capabilities as the sources for achieving competitive advantage. In this study, we attempt to identify, exploit, and analyze growth opportunity of a Ma...

  18. Adding some context to port marketing: Exploring the content and measurement of market orientation in the port industry

    OpenAIRE

    Kounoupas, Evangelos; Pardali, Angeliki

    2015-01-01

    Understanding and responding to customer needs is the essence of the marketing concept and as such it has been discussed in various fields of business and economic literature. Port economics and management literature has thoroughly investigated areas such as port efficiency and effectiveness, understanding and overcoming competitive pressures and identifying the sources of potential sustainable competitive advantage. In line with this discussion, albeit with a significant time delay, port eco...

  19. SNS Diagnostics

    International Nuclear Information System (INIS)

    Shea, T.J.; Cameron, P.; Doolittle, L.; Power, J.

    2000-01-01

    The Spallation Neutron Source (SNS) Project is a collaborative effort to build the next generation neutron science facility at Oak Ridge, TN. The facility will deliver a 2 MW proton beam to a liquid mercury target. Neutrons from this target will be moderated and sent to several state-of-the-art instruments. Six national laboratories are involved in SNS construction. Berkeley (LBNL) will build the front end that produces a 2.5 MeV, 52 mA H-beam. Los Alamos (LANL) is responsible for the 1 GeV linac with a superconducting section provided by Thomas Jefferson (JLab). Brookhaven (BNL) is building the transfer lines and accumulator ring. Oak Ridge (ORNL) and Argonne (ANL) have responsibility for the target and instruments. All activities are coordinated by the SNS project office at Oak Ridge. The high beam power, a desired availability of 95%, and an aggressive commissioning schedule lead to some interesting challenges in beam diagnostics

  20. Upper Extremity Injuries in Tennis Players: Diagnosis, Treatment, and Management.

    Science.gov (United States)

    Chung, Kevin C; Lark, Meghan E

    2017-02-01

    Upper extremity tennis injuries are most commonly characterized as overuse injuries to the wrist, elbow, and shoulder. The complex anatomy of these structures and their interaction with biomechanical properties of tennis strokes contributes to the diagnostic challenges. A thorough understanding of tennis kinetics, in combination with the current literature surrounding diagnostic and treatment methods, will improve clinical decision-making. Copyright © 2016 Elsevier Inc. All rights reserved.

  1. An overview of San Francisco Bay PORTS

    Science.gov (United States)

    Cheng, Ralph T.; McKinnie, David; English, Chad; Smith, Richard E.

    1998-01-01

    The Physical Oceanographic Real-Time System (PORTS) provides observations of tides, tidal currents, and meteorological conditions in real-time. The San Francisco Bay PORTS (SFPORTS) is a decision support system to facilitate safe and efficient maritime commerce. In addition to real-time observations, SFPORTS includes a nowcast numerical model forming a San Francisco Bay marine nowcast system. SFPORTS data and nowcast numerical model results are made available to users through the World Wide Web (WWW). A brief overview of SFPORTS is presented, from the data flow originated at instrument sensors to final results delivered to end users on the WWW. A user-friendly interface for SFPORTS has been designed and implemented. Appropriate field data analysis, nowcast procedures, design and generation of graphics for WWW display of field data and nowcast results are presented and discussed. Furthermore, SFPORTS is designed to support hazardous materials spill prevention and response, and to serve as resources to scientists studying the health of San Francisco Bay ecosystem. The success (or failure) of the SFPORTS to serve the intended user community is determined by the effectiveness of the user interface.

  2. Strategic and Operational Plan Implementation of Seaports (Utilization Jeddah Port

    Directory of Open Access Journals (Sweden)

    Akram Elentably

    2015-12-01

    Full Text Available The Port of Jeddah (Port released the initial version of this Strategic Plan in 2006. It was developed by Port staff, along with input, as a five-year rolling plan designed to guide the Port’s future development while keeping in mind the needs of our tenants, local community members and stakeholders, and the nation. This is the second update to the Strategic Plan since its initial release. While the Port’s overarching principles – commitment to environmental stewardship, addressing tenant needs, goods movement, economic development, and security – have remained largely unchanged, it is important for us to adapt our strategies to meet the challenges of an ever changing local and global environment. The Port is among the world’s premier ports and is a critical hub for global trade. This prominence brings with it responsibilities and expectations for the highest possible standards for efficiency, safety and security, and environmental leadership. The Port is the nation’s busiest container port and part of the world’s busiest port complex, handling 3.7 million twenty-foot equivalent units in 2013. Global trade and goods movement is Western kingdom of Saudi Arabia’s strongest industries in terms of jobs and economic activity. The Port of Jeddah powers these industries, handling almost more than a quarter of the cargo that enters the kingdom of Saudi Arabia annually. Through the Port’s activities, a lot of jobs are created in western kingdom of Saudi Arabia and over five hundred thousand nationwide. In order to maintain our position among the world’ the kingdom of Saudi Arabia premier ports, the Port is continually addressing the demands for providing modern and efficient cargo handling terminals as well as transportation and infrastructure projects. Protecting one of the nation’s most vital economic hubs is also an ongoing challenge. Finally, promoting a sustainable “grow green” philosophy and ensuring that we are the leader

  3. Diagnostic and therapeutic peroral cholangioscopy

    Directory of Open Access Journals (Sweden)

    Jong Ho Moon

    2012-01-01

    Full Text Available Peroral cholangioscopy (POC provides direct visualization of the bile duct and facilitates diagnostic or therapeutic intervention. The currently available single-operator POC systems are "Mother-baby" scope system, SpyGlass direct visualization system, and direct POC using a regular ultra-slim upper endoscope. Direct POC using an ultra-slim upper endoscope having a larger 2-mm working channel can provide a valuable and economic solution for evaluating bile-duct lesions. Main diagnostic procedures under direct POC are visual characterization and optically guided target biopsy for the indeterminate bile duct lesion. Image-enhanced endoscopy such as narrow-band imaging has shown promise for more detailed evaluation of mucosal abnormality and can be performed under direct POC. Intracorporeal lithotripsy such as electrohydraulic lithotripsy or laser lithotripsy is a main therapeutic intervention of direct POC for patients with bile duct stones that are resistant to conventional endoscopic stone-removal procedures. Besides, tumor ablation therapy, such as photodynamic therapy and argon plasma coagulation may be also performed using direct POC. Further developments of the endoscope and specialized accessories or devices are expected to facilitate diagnostic and therapeutic role of this cholangioscopic procedure.

  4. Environmental reform of West and Central Africa ports

    NARCIS (Netherlands)

    Barnes-Dabban, Harry; Koppen, Van Kris; Mol, Arthur

    2017-01-01

    West and Central Africa ports have historically not paid much attention to environmental issues. In the past decade, however, environmental concerns are beginning to emerge with pockets of innovative responses to environmental risks as the ports undergo institutional and infrastructural reform –

  5. 33 CFR 80.1440 - Port Allen, Kauai, HI.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 1 2010-07-01 2010-07-01 false Port Allen, Kauai, HI. 80.1440 Section 80.1440 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY INTERNATIONAL NAVIGATION RULES COLREGS DEMARCATION LINES Pacific Islands § 80.1440 Port Allen, Kauai, HI. A line drawn from...

  6. Port supply chain integration : analyzing biofuel supply chains

    NARCIS (Netherlands)

    Stevens, Leonie C. E.; Vis, Iris F. A.

    2016-01-01

    This paper focuses on port supply chain integration to strengthen operational and business performance. We provide a structured and comprehensive method to enable port supply chain integration and demonstrate its applicability to the biofuel supply chain. We define the value proposition, role,

  7. 7 CFR 319.55-3 - Ports of entry.

    Science.gov (United States)

    2010-01-01

    ... through Mexican border ports and such other ports as may later be approved by the Plant Protection and... Plant Protection and Quarantine Programs. (c) Pending development of adequate treating facilities in... Regulations of the Department of Agriculture (Continued) ANIMAL AND PLANT HEALTH INSPECTION SERVICE...

  8. 33 CFR 110.155 - Port of New York.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 1 2010-07-01 2010-07-01 false Port of New York. 110.155 Section... ANCHORAGE REGULATIONS Anchorage Grounds § 110.155 Port of New York. (a) Long Island Sound—(1) Anchorage No... northwest corner of the crib icebreaker north of the New York Central Railroad Company drawbridge across...

  9. 75 FR 22323 - Anchorage Regulations; Port of New York

    Science.gov (United States)

    2010-04-28

    ...-AA01 Anchorage Regulations; Port of New York AGENCY: Coast Guard, DHS. ACTION: Supplemental notice of..., Coast Guard Sector New York, Waterways Management Division; telephone 718-354-4195, e-mail Jeff.M.Yunker... Purpose The Hudson River Pilots Association, through the Port of New York/ New Jersey Harbor Safety...

  10. Exploration of an ancient port: Elephanta Island (Bombay)

    Digital Repository Service at National Institute of Oceanography (India)

    Rao, S.R.; Gaur, A; Tripati, S.

    of amphora sherds were recovered from the site. Morabandar was busy port during 4th-5th century AD as a large number of coins of this period have been found. While Shetbandar served as port till modern period. Onshore and inter tidal zone explorations brought...

  11. Treatment of acute appendicitis with one-port transumbilical ...

    African Journals Online (AJOL)

    Background: Laparoscopic appendectomy is a feasible and safe alternative to open appendectomy for uncomplicated appendicitis. In the past decade several laparoscopic procedures have been described using one or more ports. We report our experience in treating acute appendicitis with one-port transumbilical ...

  12. Spatio-Temporal Variations in Urban Vehicular Emission in Port ...

    African Journals Online (AJOL)

    vThe increasing high volume of road traffic and congestion is a fundamental issue in Port Harcourt metropolis. The degradation of air quality arising from these is another serious dimension of the problem. This study estimated the emissions of pollutants from vehicles during traffic peak periods within parts of the city of Port ...

  13. Sustainability as a procurement criterion for port investments

    NARCIS (Netherlands)

    Broesterhuizen, E.F.M.; Vellinga, T.; Docters van Leeuwen, L.; Taneja, P.; Zwakhals, J.W.; Nijdam, M.H.

    2012-01-01

    Ports are known to be one of the most polluting sectors, and therefore provide an opportunity to reduce emission significantly. Until now, the attention has been given to reduction of emissions in transport and shipping. The scope of research must expand to include port infrastructures, which should

  14. Port-Orford-cedar—a poor risk for reforestation.

    Science.gov (United States)

    John Hunt; Edward J. Dimock

    1957-01-01

    Port-Orford-cedar (Chamaecyparis lawsoniana (A. Murr.) Parl.) has been the most widely used introduced species in reforestation projects in western Washington and Oregon. However, as a result of two recent and unrelated occurrences, a severe early cold wave and a destructive root disease, the advisability of continued planting of Port-Orford-cedar...

  15. Model reduction of port-Hamiltonian systems as structured systems

    NARCIS (Netherlands)

    Polyuga, R.V.; Schaft, van der A.J.

    2010-01-01

    The goal of this work is to demonstrate that a specific projection-based model reduction method, which provides an H2 error bound, turns out to be applicable to port-Hamiltonian systems, preserving the port-Hamiltonian structure for the reduced order model, and, as a consequence, passivity.

  16. Malaria infection and socioeconomic status of some residents of Port ...

    African Journals Online (AJOL)

    The study investigated the prevalence of malaria and socioeconomic status of subjects in part of Port Harcourt metropolis. Following ethical clearance which was obtained from the University of Port Harcourt and the parents of the subjects who gave their written consents, blood samples were collected and analysed ...

  17. Infant feeding tube as urinary tract stent | Ekeke | Port Harcourt ...

    African Journals Online (AJOL)

    Methods: Data from the hospital records of patients who required stents at the University of Port Harcourt Teaching Hospital, Port Harcourt, Nigeria were obtained from their case notes from May 2003 to May 2006. Information extracted from these case notes included: age and sex of patient, indications for stenting, ...

  18. 3D Spatial Information Infrastructure for the Port of Rotterdam

    NARCIS (Netherlands)

    Zlatanova, S.; Beetz, J.; Boersma, A.J.; Mulder, A.; Goos, J.

    2013-01-01

    The maintenance of the complex infrastructure and facilities of Port of Rotterdam is based on large amounts of heterogeneous information. Almost all activities of the Port require spatial information about features above- and under- ground. Current information systems are department and data

  19. Perception of undergraduates of University of Port Harcourt towards ...

    African Journals Online (AJOL)

    Aim: To assess the perception of undergraduates in University of Port Harcourt towards the use of condom. Methods: A cross-sectional questionnaire survey on the knowledge and use of condom among undergraduates of University of Port Harcourt. A systematic random sampling method was employed. Data collected was ...

  20. Perception of Rape Amongst Secondary School Students In Port ...

    African Journals Online (AJOL)

    Alasia Datonye

    Department of Paediatrics and Child health, University of Port Harcourt, Teaching Hospital,. Port Harcourt, Nigeria. ABSTRACT ... questionnaire, data collected included bio data, awareness information, response and practices. ..... behaviour and experience of sexual coercion among secondary school studenta in three ...

  1. Queuing theory models used for port equipment sizing

    Science.gov (United States)

    Dragu, V.; Dinu, O.; Ruscă, A.; Burciu, Ş.; Roman, E. A.

    2017-08-01

    The significant growth of volumes and distances on road transportation led to the necessity of finding solutions to increase water transportation market share together with the handling and transfer technologies within its terminals. It is widely known that the biggest times are consumed within the transport terminals (loading/unloading/transfer) and so the necessity of constantly developing handling techniques and technologies in concordance with the goods flows size so that the total waiting time of ships within ports is reduced. Port development should be achieved by harmonizing the contradictory interests of port administration and users. Port administrators aim profit increase opposite to users that want savings by increasing consumers’ surplus. The difficulty consists in the fact that the transport demand - supply equilibrium must be realised at costs and goods quantities transiting the port in order to satisfy the interests of both parties involved. This paper presents a port equipment sizing model by using queueing theory so that the sum of costs for ships waiting operations and equipment usage would be minimum. Ship operation within the port is assimilated to a mass service waiting system in which parameters are later used to determine the main costs for ships and port equipment.

  2. 77 FR 75823 - Closing of the Port of Whitetail, MT

    Science.gov (United States)

    2012-12-26

    ... Canada Border Services Agency's (CBSA) closure of its adjacent port of entry of Big Beaver, Saskatchewan... almost all of the decrease in southbound traffic occurring after CBSA closed the port of Big Beaver to... of entry. CBP expects that any impact on the environment and any costs incurred for this purpose will...

  3. Itinerary planning: Modelling cruise lines’ lengths of stay in ports

    NARCIS (Netherlands)

    Chen, Jamie M.; Nijkamp, Peter

    Cruise tourism is a fast-growing segment of the tourism industry that generates substantial benefits to port cities. This study explores strategic aspects of cruise lines’ itinerary planning, and models the determinants of their lengths of stay in ports, based on extensive observations of network

  4. 19 CFR 146.2 - Port director as Board representative.

    Science.gov (United States)

    2010-04-01

    ...; DEPARTMENT OF THE TREASURY (CONTINUED) FOREIGN TRADE ZONES General Provisions § 146.2 Port director as Board representative. The appropriate port director shall be in charge of the zone as the representative of the Board. [T.D. 86-16, 51 FR 5049, Feb. 11, 1986, as amended by T.D. 99-27, 64 FR 13676, Mar. 22, 1999] ...

  5. Characteristics of drayage operations at the Port of Houston.

    Science.gov (United States)

    2008-09-01

    Port drayage, defined as a container truck pickup to or from a seaport terminal with both the trip : origin and destination in the same urban area, is a critical yet comparatively understudied link in the : intermodal supply chain. Because port dray ...

  6. Challenges and Strategies of Abidjan Port-Hinterland Connectivity

    Directory of Open Access Journals (Sweden)

    Gamassa Pascal Kany Prud’ome

    2017-01-01

    Full Text Available Abidjan port-hinterland is composed of three countries which include Ivory Coast, Mali and Burkina Faso. The fast economic growth of the above countries resulted to a greater demand for the foreign goods from their population, causing a congestion problem at Abidjan port. Because of this problem, the connectivity movement between the port and its hinterland has considerably slowed down. In this article a qualitative methodology is used to analyse the Abidjan port-hinterland connectivity. The constant delays of the train services, the road congestion and the lack of coordination and communication between Abidjan port and its hinterland customers are the main presented challenges. The results of this research demonstrate that the poor quality roads and railways and the lack of a new dry port in Ivory Coast greatly affects the fluidity of the Abidjan port-hinterland connectivity. This article suggests some strategies on how to solve the current challenges and will be helpful in deciding on how the Abidjan port should be developed better and improve its connectivity with its hinterland.

  7. Port Hamiltonian Formulation of Infinite Dimensional Systems I. Modeling

    NARCIS (Netherlands)

    Macchelli, Alessandro; Schaft, Arjan J. van der; Melchiorri, Claudio

    2004-01-01

    In this paper, some new results concerning the modeling of distributed parameter systems in port Hamiltonian form are presented. The classical finite dimensional port Hamiltonian formulation of a dynamical system is generalized in order to cope with the distributed parameter and multi-variable case.

  8. Lasers or light sources for treating port-wine stains

    DEFF Research Database (Denmark)

    Faurschou, Annesofie; Olesen, Anne Braae; Leonardi-Bee, Jo

    2011-01-01

    Port-wine stains are birthmarks caused by malformations of blood vessels in the skin. Port-wine stains manifest themselves in infancy as a flat, red mark and do not regress spontaneously but may, if untreated, become darker and thicker in adult life. The profusion of various lasers and light...

  9. Two-port Laparoscopic-assisted Appendicectomy Under Local ...

    African Journals Online (AJOL)

    Journal of Surgical Technique and Case Report | Jul-Dec 2011 | Vol-3 | Issue-2. 84. Two-port Laparoscopic-assisted ... appendicectomy (LAA) using the two-port technique under local anesthesia in adults. As a pilot study we .... of failure are the reasons for avoidance of using local anesthesia for surgical procedures.

  10. 49 CFR 176.4 - Port security and safety regulations.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 2 2010-10-01 2010-10-01 false Port security and safety regulations. 176.4... SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION HAZARDOUS MATERIALS REGULATIONS CARRIAGE BY VESSEL General § 176.4 Port security and safety regulations. (a) Each carrier, master, agent, and charterer of a...

  11. An effective strategy for porting C++ applications on cell

    NARCIS (Netherlands)

    Varbanescu, A.L.; Sips, H.; Ross, K.A.; Liu, Q.; Liu, L.K.; Natsev, A.; Smith, J.R.

    2007-01-01

    In this paper we present a solution for efficient porting of sequential C++ applications on the Cell B.E. processor. We present our step-by-step approach, focusing on its generality, we provide a set of code templates and optimization guidelines to support the porting, and we include a set of

  12. 46 CFR 171.118 - Automatic ventilators and side ports.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Automatic ventilators and side ports. 171.118 Section 171.118 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) SUBDIVISION AND STABILITY... Bulkhead or Weather Deck § 171.118 Automatic ventilators and side ports. (a) An automatic ventilator must...

  13. Very High Frequency Two-Port Characterization of Transistors

    DEFF Research Database (Denmark)

    Hertel, Jens Christian; Nour, Yasser; Jørgensen, Ivan Harald Holger

    To properly use transistors in VHF converters, they need to be characterized under similar conditions. This research presents a two-port method, using a network analyzer (NWA) with a S-port setup. The method is a one-shot method, providing fast results of the off-state parasitics of the transistors....

  14. Agent Technology supports Inter-Organizational Planning in the Port

    NARCIS (Netherlands)

    J.M. Moonen (Hans); B. van de Rakt (Bastiaan); I. Miller; J.A.E.E. van Nunen (Jo); J. van Hillegersberg (Jos)

    2005-01-01

    textabstractThe Port of Rotterdam is a key container transshipment hub for Europe. Inland container shipping is important to connect the hinterland (40% market share). Barges visit several terminals per round-trip through the Port, thus requiring a proper planning support – to avoid planning

  15. Port exteriorization appendectomy in children: An alternative to the ...

    African Journals Online (AJOL)

    Introduction Laparoscopic appendectomy is usually performed using an intracorporeal approach. The conventional procedure uses three ports. The port exteriorization appendectomy uses two trocars to perform the entire procedure and can be considered an efficient alternative to the conventional approach, especially in ...

  16. RIVERS AND PORTS IN TRANSPORT HISTORY OF CAMEROON ...

    African Journals Online (AJOL)

    Dean SPGS NAU

    importance of the ports in the development of the cities and the migration of people ... known to have developed in this region with technological .... Douala port as a case study. .... taking place. Traders came from West African coast, Greece and. France. .... global networks have not been limited to particular hubs but rather.

  17. Structure preserving port-Hamiltonian model reduction of electrical circuits

    NARCIS (Netherlands)

    Polyuga, R.; Schaft, van der A.J.; Benner, P.; Hinze, M.; Maten, ter E.J.W.

    2011-01-01

    This paper discusses model reduction of electrical circuits based on a port-Hamiltonian representation. It is shown that by the use of the Kalman decomposition an uncontrollable and/or unobservable port-Hamiltonian system is reduced to a controllable/observable system that inherits the

  18. Safety shield for vacuum/pressure chamber viewing port

    Science.gov (United States)

    Shimansky, R. A.; Spencer, R. S. (Inventor)

    1981-01-01

    Observers are protected from flying debris resulting from a failure of a vacuum or pressure chamber viewing port following an implosion or explosion by an optically clear shatter resistant safety shield which spaced apart from the viewing port on the outer surface of the chamber.

  19. Prostate cancer in Port Harcourt, Nigeria: features and outcome ...

    African Journals Online (AJOL)

    Background: To present the clinical features and outcome of management of patients with prostate cancer in Port Harcourt, Nigeria. Methods: A retrospective study of patients with prostate cancer managed in 14 years at the University of Port Harcourt Teaching Hospital. Results: Of 154,594 men above 40 years old who ...

  20. The Long Shadow of Port Infrastructure in Germany

    DEFF Research Database (Denmark)

    Mitze, Timo Friedel; Breidenbach, Philipp

    2016-01-01

    . Since it is very likely that results from least square estimations suffer from endogeneity problems, we base the identification on exogenous long-run instruments. In particular, port facilities built before the industrial revolution provide an adequate instrument for current port infrastructure since...

  1. Toxicity evaluation of ballast water discharged at The Onne Port ...

    African Journals Online (AJOL)

    The discharge of these ballast water poses a major environmental threat to the water quality and Port infrastructures at the Onne Port complex as contaminants may find their way into the food chain/food web and bioaccumulate in the tissues of indigenous biota (microorganisms, crabs, mangrove oysters and fin-fishes).

  2. Upper Respiratory Tract Diseases in Athletes in Different Sports Disciplines.

    Science.gov (United States)

    Gałązka-Franta, Anna; Jura-Szołtys, Edyta; Smółka, Wojciech; Gawlik, Radosław

    2016-12-01

    Upper respiratory tract diseases in athletes are a very common medical problem. Training conditions in different sports disciplines increase the risk of upper respiratory disease. Epidemiological evidence suggests that heavy acute or chronic exercise is related to an increased incidence of upper respiratory tract infections in athletes. Regular physical exercise at high intensity may lead to transient immunosuppression due to high prevalence of allergic diseases in athletes. Regardless of the cause they can exclude athletes from the training program and significantly impair their performance. In the present work, the most common upper respiratory tract diseases in athletes taking into account the disciplines in which they most often occur were presented. The focus was laid on symptoms, diagnostic methods and pharmacotherapy. Moreover, preventive procedures which can help reduce the occurrence of upper respiratory tract disease in athletes were presented. Management according to anti-doping rules, criteria for return to training and competition as an important issues of athlete's health were discussed.

  3. Ballast Water Risk Assessment, Ports of Mumbai and Jawaharlal Nehru, India, October 2003: Final Report

    Digital Repository Service at National Institute of Oceanography (India)

    Anil, A.C.; Clarke, C.; Hayes, T.; Hilliard, R.; Joshi, G.; Krishnamurthy, V.; Polglaze, J.; Sawant, S.S.; Raaymakers, S.

    This report describes the BWRA activity undertaken for the neighbouring ports of Mumbai and Jawaharlal Nehru, which form the Mumbai Demonstration Site and are managed by the Mumbai Port Trust (MPT) and Jawaharlal Nehru Port Trust (JNPT) respectively...

  4. Goods Movement and Ports: Community Impacts and Collaborative Solutions (January 2014 Webinar)

    Science.gov (United States)

    To exchange views and develop a shared understanding of the challenges and opportunities of ports and port communities, EPA's Office of Transportation and Air Quality is hosting a series of webinars, bringing together port stakeholders.

  5. Diagnostic thoracoscopy

    Directory of Open Access Journals (Sweden)

    Plavec Goran

    2002-01-01

    Full Text Available Diagnostic thoracoscopy in patients with pleural effusion of unclear origin mostly provides the correct diagnosis. Results from published reports of previous researches are not uniform. In 47 male and 20 female patients with pleural effusion of unknown etiology, after receiving negative results obtained from cytological finding of pleural effusion and percutaneous needle biopsy, thoracoscopy with biopsy of one or both pleurae was performed. Procedure was done in local anesthesia using Stortz rigid thoracoscope. In 37 patients with malignant disease (primary or metastatic diagnosis was confirmed histopathologically in 31 patient (81.12%. In 27 patients with inflammatory pleural disease diagnosis was confirmed histopathologically in 22 patients (81.4%. Among 11 patients with specific pleural effusions, tuberculosis was confirmed in 10 (90.91%. Normal finding in cases of spontaneous pneumothorax and pulmonary embolism was taken as a positive result. Total number of positive findings was 55 (82.10%. In one patient, the third spontaneous pneumothorax was the indication for thoracoscopy, and after numerous bullae were seen during the procedure, talcum powder pleurodesis was done. In four patients low intensity subcutaneous emphysema occurred one day after thoracoscopy. It can be concluded that thoracoscopy in local anesthesia out of the operating room is good and practical method for solving the unclear pleural effusions, with neglectable rate of complications.

  6. Clinical advantages of single port laparoscopic hepatectomy.

    Science.gov (United States)

    Han, Jae Hyun; You, Young Kyoung; Choi, Ho Joong; Hong, Tae Ho; Kim, Dong Goo

    2018-01-21

    To evaluate the clinical advantages of single-port laparoscopic hepatectomy (SPLH) compare to multi-port laparoscopic hepatectomy (MPLH). We retrospectively reviewed the medical records of 246 patients who underwent laparoscopic liver resection between January 2008 and December 2015 at our hospital. We divided the surgical technique into two groups; SPLH and MPLH. We performed laparoscopic liver resection for both benign and malignant disease. Major hepatectomy such as right and left hepatectomy was also done with sufficient disease-free margin. The operative time, the volume of blood loss, transfusion rate, and the conversion rate to MPLH or open surgery was evaluated. The post-operative parameters included the meal start date after operation, the number of postoperative days spent in the hospital, and surgical complications was also evaluated. Of the 246 patients, 155 patients underwent SPLH and 91 patients underwent MPLH. Conversion rate was 22.6% in SPLH and 19.8% in MPLH ( P = 0.358). We performed major hepatectomy, which was defined as resection of more than 2 sections, in 13.5% of patients in the SPLH group and in 13.3% of patients in the MPLH group ( P = 0.962). Mean operative time was 136.9 ± 89.2 min in the SPLH group and 231.2 ± 149.7 min in the MPLH group ( P started earlier in the SPLH group (1.06 ± 0.27 d after operation) than in the MPLH group (1.63 ± 1.27 d) ( P < 0.001). The mean hospital stay after operation was non-significantly shorter in the SPLH group than in the MPLH group (7.82 ± 2.79 d vs 7.97 ± 3.69 d, P = 0.744). The complication rate was not significantly different ( P = 0.397) and there was no major perioperative complication or mortality case in both groups. Single-port laparoscopic liver surgery seems to be a feasible approach for various kinds of liver diseases.

  7. Climate variability and Port wine quality

    Science.gov (United States)

    Gouveia, Celia; Liberato, Margarida L. R.; Trigo, Ricardo M.; Dacamara, Carlos

    2010-05-01

    Recent warming trends for Portugal have been found to be steepest in winter and spring and more pronounced for minimum than for maximum values of temperature (Miranda et al, 2002). These trends and associated changes in temperature and precipitation regimes may exert strong influences on agriculture systems. For instance, high values of the North Atlantic Oscillation (NAO) index have been shown to significantly reduce precipitation over Iberia and therefore induce low yield wheat crops in Portugal (Gouveia and Trigo, 2006). Port wine is produced from grapes grown in selected areas of the Douro valley, the so-called Região Demarcada do Douro, the first wine-producing region of the world (dating from 1758). A vintage wine is made from grapes that were grown and harvested in a single specified year and is classified as such because of the above average quality, a status that is attributed by Port houses in their best years. The Douro region presents distinctive climatic, topographic and soil characteristics. While the latest factors are fixed in time, the former may considerably change from year to year, exposing the Port wine productions to a large risk associated to interannual and intra-seasonal climatic variations. It is therefore to be expected that high quality wines are generally associated to optimum climatic conditions. In this work we have performed an analysis of the distinct behaviour of several meteorological fields in vintage versus non-vintage years. The relative importance of maximum and minimum temperature, precipitation and frost days is assessed for each individual month of the vegetative cycle and their importance to a high quality wine year is evaluated. Composites of 500 hPa geopotential height and sea level pressure fields over the Euro Atlantic region are also compared for vintage and non-vintage years. Results reveal a strong dependence of vintage production on maximum temperature and precipitation during spring and summer (the growing season

  8. The state-of-the-art port of entry workshop

    Energy Technology Data Exchange (ETDEWEB)

    Godfrey, B.

    1995-05-01

    The increased demand for freight movements through international ports of entry and the signing of the North American Free Trade Agreement (NAFTA) have increased freight traffic at border ports of entry. The State-of-the-Art Port of Entry Workshop initiated a dialogue among technologists and stakeholders to explore the potential uses of technology at border crossings and to set development priorities. International ports of entry are both information and labor intensive, and there are many promising technologies that could be used to provide timely information and optimize inspection resources. Participants universally held that integration of technologies and operations is critical to improving port services. A series of Next Steps was developed to address stakeholder issues and national priorities, such as the National Transportation Policy and National Drug Policy. This report documents the views of the various stakeholders and technologists present at the workshop and outlines future directions of study.

  9. Towards port sustainability through probabilistic models: Bayesian networks

    Directory of Open Access Journals (Sweden)

    B. Molina

    2018-04-01

    Full Text Available It is necessary that a manager of an infrastructure knows relations between variables. Using Bayesian networks, variables can be classified, predicted and diagnosed, being able to estimate posterior probability of the unknown ones based on known ones. The proposed methodology has generated a database with port variables, which have been classified as economic, social, environmental and institutional, as addressed in of smart ports studies made in all Spanish Port System. Network has been developed using an acyclic directed graph, which have let us know relationships in terms of parents and sons. In probabilistic terms, it can be concluded from the constructed network that the most decisive variables for port sustainability are those that are part of the institutional dimension. It has been concluded that Bayesian networks allow modeling uncertainty probabilistically even when the number of variables is high as it occurs in port planning and exploitation.

  10. Dry Port Location Problem: A Hybrid Multi-Criteria Approach

    Directory of Open Access Journals (Sweden)

    BENTALEB Fatimazahra

    2016-03-01

    Full Text Available Choosing a location for a dry port is a problem which becomes more essential and crucial. This study deals with the problem of locating dry ports. On this matter, a model combining multi-criteria (MACBETH and mono-criteria (BARYCENTER methods to find a solution to dry port location problem has been proposed. In the first phase, a systematic literature review was carried out on dry port location problem and then a methodological classification was presented for this research. In the second phase, a hybrid multi-criteria approach was developed in order to determine the best dry port location taking different criteria into account. A Computational practice and a qualitative analysis from a case study in the Moroccan context have been provided. The results show that the optimal location is very convenient with the geographical region and the government policies.

  11. Target Diagnostics Supports NIF's Path to Ignition

    International Nuclear Information System (INIS)

    Shelton, R.

    2011-01-01

    the RAGS system. Three new instrument controllers were developed and commissioned to support this diagnostic. A residual-gas analyzer (RGA) instrument measures the gas content at various points in the system. The Digital Gamma Spectrometer instrument measures the radiological spectrum of the decaying gas isotopes. A final instrument controller was developed to interface to a PLC based Gas collection system. In order to support the implosion velocity measurements an additional Gated X-ray Detector (GXD) diagnostic was tested and commissioned. This third GXD views the target through a slit contained in its snout and allows the other GXD diagnostics to be used for measuring the shape on the same shot. In order to measure the implosion shape in a high neutron environment, Actide Readout In A Neutron Environment (ARIANE) and Neutron Imaging (NI) diagnostics were commissioned. The controls for ARIANE, a fixed port gated x-ray imager, contain a neutron shielded camera and micro channel plate pulser with its neutron sensitive electronics located in the diagnostic mezzanine. The NI diagnostic is composed of two Spectral Instruments SI-1000 cameras located 20M from the target and provides neutron images of the DT hot spot for high yield shots. The development and commissioning of these new or enhanced diagnostics in FY11 have provided meaningful insight that facilitates the optimization of the four key Ignition variables. In FY12 they will be adding three new diagnostics and enhancing four existing diagnostics in support of the continuing optimization series of campaigns.

  12. Challenges of ITER diagnostic electrical services

    Energy Technology Data Exchange (ETDEWEB)

    Encheva, A., E-mail: anna.encheva@iter.org [ITER Organization, Route de Vinon sur Verdon, 13115 St Paul-Lez-Durance (France); Omran, H. [Oxford Technologies Ltd, 7 Nuffield Way, Abingdon OX14 1RL (United Kingdom); Pérez-Lasala, M. [The European Joint Undertaking for ITER and the Development of Fusion Energy, c/Josep Pla, n° 2, Torres Diagonal Litoral, Edificio B3, 08019 Barcelona (Spain); Alekseev, A. [Efremov Institute, Metallostroy, Doroga na Metallostroy, 3 bld., Saint-Petersburg 196641 (Russian Federation); Arshad, S. [The European Joint Undertaking for ITER and the Development of Fusion Energy, c/Josep Pla, n° 2, Torres Diagonal Litoral, Edificio B3, 08019 Barcelona (Spain); Bede, O. [Oxford Technologies Ltd, 7 Nuffield Way, Abingdon OX14 1RL (United Kingdom); Bender, S. [Efremov Institute, Metallostroy, Doroga na Metallostroy, 3 bld., Saint-Petersburg 196641 (Russian Federation); Bertalot, L.; Direz, M.-F.; Drevon, J.-M.; Jakhar, S.; Kaschuk, Y.; Komarov, V.; Lebarbier, R. [ITER Organization, Route de Vinon sur Verdon, 13115 St Paul-Lez-Durance (France); Lucca, F. [L.T. Calcoli SaS, Piazza Prinetti 26/B, 23807 Merate (Italy); Macklin, B.; Maquet, P. [ITER Organization, Route de Vinon sur Verdon, 13115 St Paul-Lez-Durance (France); Marin, A. [L.T. Calcoli SaS, Piazza Prinetti 26/B, 23807 Merate (Italy); Martin, A. [ITER Organization, Route de Vinon sur Verdon, 13115 St Paul-Lez-Durance (France); Mills, S. [Oxford Technologies Ltd, 7 Nuffield Way, Abingdon OX14 1RL (United Kingdom); and others

    2013-10-15

    Highlights: • A brief description of all major components part of diagnostic electrical services has been given. • The integration challenges have been presented. • Design assumptions and requirements for the components have been described. • The design of the conduit/loom and the relevant analysis has been highlighted. -- Abstract: Diagnostic electrical services provide the electrical infrastructure to serve diagnostic components installed on the ITER tokamak. This infrastructure is composed of cables, connectors, cable tails, looms, conduits and feedthroughs. The diagnostic services offer as well a shelter for various instrumentations – vacuum vessel (VV), blanket and divertor. The diagnostic sensors are located on the inner and outer VV wall, on blanket shield modules, divertor cassettes and in port plugs. They require electrical cabling to extract the measurement and, in some cases, to supply electrical power to the sensors. These cables run from the sensors to feedthroughs on the VV and the port interspace or cryostat. The design and integration of all components that are part of diagnostic electrical services is an important engineering activity that is being challenged by the multiple requirements and constraints which have to be satisfied while at the same time delivering the required diagnostic performance. The positioning of the components must correlate not only with their functional specifications but also with the design of the major ITER components. This is a particular challenge because not all systems have reached the same level of design maturity. This paper outlines the engineering challenges of ITER diagnostics electrical services. The environmental conditions inside the VV will have an important impact. Leading risks to these components include poor electrical contact at connectors, the effects of exposure to nuclear irradiation, such as material transmutation, heating, and generation of spurious electrical signals etc., failure due to

  13. Fusion alpha loss diagnostic for ITER using activation technique

    Czech Academy of Sciences Publication Activity Database

    Bonheure, G.; Hult, M.; González de Orduña, R.; Vermaercke, P.; Murari, A.; Popovichev, S.; Mlynář, Jan

    2011-01-01

    Roč. 86, 6-8 (2011), s. 1298-1301 ISSN 0920-3796. [Symposium on Fusion Technology (SOFT) /26th./. Port o, 27.09.2010-01.10.2010] Institutional research plan: CEZ:AV0Z20430508 Keywords : ITER * fusion product * burning plasma diagnostics * alpha losses * activation technique Subject RIV: BL - Plasma and Gas Discharge Physics Impact factor: 1.490, year: 2011 http://www.sciencedirect.com/science/article/pii/S0920379611002778

  14. Climate change considerations for the Port Hope area initiative

    International Nuclear Information System (INIS)

    Kirklady, J.; Morassutti, M.; Tamm, J.; Coutts, P.; Chambers, D.

    2006-01-01

    The Port Hope Area Initiative (PHAI) is a community-based program intended to develop a safe and long-term (approximately 500 years) solution for the management of historic low-level radioactive waste (LLRW) that has been present in the Port Hope area for many years. The PHAI undertakings involve the construction and management of two Long-Term Low-Level Radioactive Waste Management Facilities (referred to as the LTWMFs) in Port Hope and in Port Granby. These undertakings are currently undergoing detailed examination through the Environmental Screening process under the Canadian Environmental Assessment Act. The purpose of the study described in this paper was to provide information necessary to satisfy the requirements of the Scope of Environmental Assessment for the Port Hope and Port Granby Projects. In particular, the purpose of the study was to satisfy the requirements to evaluate greenhouse gas (GHG) emissions from the proposed PHAI initiatives and to evaluate the potential effect of climate change parameters on the two Projects. The Port Hope and Port Granby Projects will contribute to Ontario's GHG emission inventory due to vehicle exhaust from excavation equipment and haul trucks during the construction phase of the LTWMFs. The construction phase of the Projects is of relatively short duration, and the contribution of GHGs from each Project was determined to be insignificant compared to Ontario's GHG emissions from the Construction and Transportations sectors. The proposed project elements associated with the Port Hope and Port Granby Projects were each evaluated with respect to potential sensitivities to future change in climate parameters. Considering the potential changes to climate, a screening analysis of each element of the LTWMFs was undertaken. Because it is considered likely that the current design level storms will be exceeded within the next 500 years, it was determined that the storm water management system was potentially sensitive to changes

  15. The alternative means process for the Port Hope Area Initiative

    International Nuclear Information System (INIS)

    O'Neill, J.E.; Campbell, D.; Rossi, R.

    2006-01-01

    In March of 2001, the Government of Canada, the Town of Port Hope, Hope Township and the Municipality of Clarington agreed to the cleanup and long-term management of historic, low-level radioactive waste materials in these communities. The agreement identified conceptual designs for long-term management facilities for the wastes. Two environmental assessments (EAs) of the proposed long-term management facilities have been initiated as part of the Port Hope Area Initiative (PHAI); namely the Port Hope Long-Term Low-Level Radioactive Waste Management Project and the Port Granby Long-Term Low-Level Radioactive Waste Management Project. A requirement set out in the Scope for the EAs is the consideration of technically and economically feasible Alternative Means of carrying out the PHAI projects. Alternative Means are the various ways that the projects could be implemented, such as alternative technologies, sites, transportation routes, etc. Early in the overall EA processes the Low-Level Radioactive Waste Management Office (LLRWMO), which is responsible for undertaking the EAs, recognized that it was facing a significant challenge; namely, the successful completion of a clear, technically sound and defendable Alternative Means analysis, including consultation with and acceptance by the community. This would be a fundamental requirement for the success of the PHAI EAs. A further challenge was to develop consistent assessment methodologies for the Port Hope and Port Granby projects, which were both initiated under the PHAI at the same time. Although similar in many respects, the two projects have major differences. For example, the Port Hope Project, with more sources of contamination within a built- up urban area is more complex and has a broader range of potential solutions to be considered than the rural Port Granby Project. This paper describes how the LLRWMO met that challenge, developed and implemented a successful Alternative Means process and presents the

  16. Tsunami response system for ports in Korea

    Science.gov (United States)

    Cho, H.-R.; Cho, J.-S.; Cho, Y.-S.

    2015-09-01

    The tsunamis that have occurred in many places around the world over the past decade have taken a heavy toll on human lives and property. The eastern coast of the Korean Peninsula is not safe from tsunamis, particularly the eastern coastal areas, which have long sustained tsunami damage. The eastern coast had been attacked by 1983 and 1993 tsunami events. The aim of this study was to mitigate the casualties and property damage against unexpected tsunami attacks along the eastern coast of the Korean Peninsula by developing a proper tsunami response system for important ports and harbors with high population densities and high concentrations of key national industries. The system is made based on numerical and physical modelings of 3 historical and 11 virtual tsunamis events, field surveys, and extensive interviews with related people.

  17. Survey of industrial noise in Port Elizabeth.

    Science.gov (United States)

    Lane, J L

    1976-02-07

    The amendment to the Factories, Machinery and Building Work Act of 1941 in regard to hearing conservation is outlined. A survey by the Port Elizabeth Deaf Association on workmen from Cadbury (Pty) Ltd was undertaken in 1973 and on a second group in 1974 and the results are published and discussed. Although the numbers of workmen were small, the results suggest that widespread testing will unearth many cases of unsuspected hearing loss. The implications as applied to industry at large are discussed and the difficulties in adequately assessing large numbers of workmen with adequately trained audiometric testers are stressed. A suggestion is made that mobile clinics under the control of Chambers of Industries would be the most efficient way of approaching the screening problem, and an estimated cost structure in the setting up of such a clinic is introduced.

  18. Port of Galveston Solar Energy Project

    Energy Technology Data Exchange (ETDEWEB)

    Falcioni, Diane [Port of Galveston (POG), Galveston, TX (United States); Cuclis, Alex [Houston Advanced Research Center, The Woodlands, TX (United States); Freundlich, Alex [Univ. of Houston, Houston, TX (United States)

    2014-03-31

    This study on the performance characteristics of existing solar technologies in a maritime environment was funded by an award given to The Port of Galveston (POG) from the U.S. Department of Energy (DOE). The study includes research performed by The Center for Advanced Materials at the University of Houston (UH). The UH researchers examined how solar cell efficiencies and life spans can be improved by examining the performance of a variety of antireflective (AR) coatings mounted on the top of one of the POG’s Cruise Terminals. Supplemental supporting research was performed at the UH laboratories. An educational Kiosk was constructed with a 55” display screen providing information about solar energy, the research work UH performed at POG and real time data from the solar panels located on the roof of the Cruise Terminal. The Houston Advanced Research Center (HARC) managed the project.

  19. Heat transfer at a beam port corner

    International Nuclear Information System (INIS)

    Krinsky, S.

    Along the general run of the vacuum chamber synchrotron radiation strikes the wall at a glancing angle of about 5.6 0 . The heat source is well-approximated by a ribbon of uniform power density having a small vertical height and an infinite azimuthal length. The heat transfer problem reduces to one in two-dimensions and it has been considered in a previous note. At the corner of a beam port the angle of incidence becomes 90 0 , so the temperature rises much higher than elsewhere. Since the power density at the corner is not uniform in its azimuthal dependence, but is strongly peaked at the point of normal incidence, two-dimensional heat flow is not a good approximation. The rectangular 3d problem is considered. This is easily solved and yields a good first estimate of the temperature rise at the corner

  20. Optimization of wireless power transmission for two port and three port inductive link

    International Nuclear Information System (INIS)

    Haider, Samnan; Mansor, Hasmah; Khan, Sheroz; Arshad, Atika; Shobaki, Mohammed M; Tasnim, Rumana

    2013-01-01

    Recent developments have shown that the use of buried electronic devices or body implants has been becoming prevalent. Such low power devices are being powered up through non-contact means utilizing inductive coupling from external powering source. Inductive coupling not only solves the issue of energy availability but helps collecting the sensed data that can be archived or used for subsequent monitoring purposes. This paper analyses the performance of two-port and three-port inductive links in terms of power sent, power received and power transfer efficiency. All the above mentioned parameters have been plotted using analytical approach and obtaining simulation where required. The effect of mutual coupling has been studied in detail for both systems and demonstrated by plotting the power transfer efficiency for different values of the coefficient of coupling (k) using MATLAB. Results show that power transfer efficiency depends highly upon the value of k

  1. Upper airway evaluation

    International Nuclear Information System (INIS)

    Hoffman, E.A.; Gefter, W.B.; Schnall, M.; Nordberg, J.; Listerud, J.; Lenkinski, R.E.

    1988-01-01

    The authors are evaluating upper-airway sleep disorders with magnetic resonance (MR) imaging and x-ray cine computed tomography (CT). Fixed structural anatomy is visualized with multisection spin-echo MR imaging, the dynamic component with cine CT. Unique aspects of the study are described in this paper

  2. 77 FR 47522 - Special Local Regulation; Port Huron Offshore Gran Prix, St. Clair River; Port Huron, MI

    Science.gov (United States)

    2012-08-09

    ... 13045, Protection of Children from Environmental Health Risks and Safety Risks. This rule is not an economically significant rule and does not create an environmental risk to health or risk to safety that may...-AA08 Special Local Regulation; Port Huron Offshore Gran Prix, St. Clair River; Port Huron, MI AGENCY...

  3. Diagnosis and treatment of upper limb apraxia.

    Science.gov (United States)

    Dovern, A; Fink, G R; Weiss, P H

    2012-07-01

    Upper limb apraxia, a disorder of higher motor cognition, is a common consequence of left-hemispheric stroke. Contrary to common assumption, apraxic deficits not only manifest themselves during clinical testing but also have delirious effects on the patients' everyday life and rehabilitation. Thus, a reliable diagnosis and efficient treatment of upper limb apraxia is important to improve the patients' prognosis after stroke. Nevertheless, to date, upper limb apraxia is still an underdiagnosed and ill-treated entity. Based on a systematic literature search, this review summarizes the current tools of diagnosis and treatment strategies for upper limb apraxia. It furthermore provides clinicians with graded recommendations. In particular, a short screening test for apraxia, and a more comprehensive diagnostic apraxia test for clinical use are recommended. Although currently only a few randomized controlled studies investigate the efficacy of different apraxia treatments, the gesture training suggested by Smania and colleagues can be recommended for the therapy of apraxia, the effects of which were shown to extend to activities of daily living and to persist for at least 2 months after completion of the training. This review aims at directing the reader's attention to the ecological relevance of apraxia. Moreover, it provides clinicians with appropriate tools for the reliable diagnosis and effective treatment of apraxia. Nevertheless, this review also highlights the need for further research into how to improve diagnosis of apraxia based on neuropsychological models and to develop new therapeutic strategies.

  4. Upper gastrointestinal bleeding in irbid, jordan

    International Nuclear Information System (INIS)

    Banisalamah, A.A.; Mraiat, Z.M.

    2007-01-01

    To define the various causes of nonvariceal upper gastrointestinal bleeding, to outline management modalities and to determine the final outcome of patients. A retrospective analysis of patients presenting with upper gastrointestinal (UGI) bleeding from January 2003 to December 2006 (4 years) was conducted. Patients with endoscopically proven variceal bleeding were excluded. Out of the 120 patients, most of the patients belonged to an age group of more than 50 years (mean 48.5 years). Haematemesis was the most common presentation and Acute Gastric Mucosal Lesion (AGML) was the most frequently encountered lesion. The cause of bleeding was not identified in 10 patients (undetermined group). Twenty-two (18.3%) underwent surgery and we had an overall mortality of 15.8%. AGML being the leading cause can be managed conservatively most of the time. There is a male preponderance and the incidence and mortality increases with advancing age. The undetermined group remains a diagnostic problem. (author)

  5. Laparoscopic Cholecystectomy by Sectorisation of Port Sites

    International Nuclear Information System (INIS)

    Sindhu, M. A.; Haq, I.; Rehman, S.

    2013-01-01

    Objectives: To evaluate the results of 160 consecutive laparoscopic cholecystectomy using sectorisation based port site selection to improve ergonomics for surgeons. Design: Descriptive study. Place and Duration of study: PNS Shifa Karachi, Pakistan from Feb 2011 to Feb 2012. Patients and Methods: In this prospective study, 160 consecutive patients had undergone laparoscopic cholecystectomy in a tertiary care hospital using sectorisation for trocar placement. All patients with symptomatic gallstones, acute calculous cholecystitis and empyema gallbladder were included. Patients with choledocholithiasis were excluded from the study. The collected data included age, sex, diagnosis, history of previous surgery, conversion to open surgery and its reasons, operative time, post-operative hospital stay, complications and laparoscopy related complications to the surgeon such as shoulder pain, wrist stress and pain, finger joint pain and stress exhaustion. Result: One hundred and sixty patients underwent laparoscopic cholecystectomy with mean age 45 +- 12.9 years. Female to male ratio was 7.8:1. A total of 110 patients had chronic cholecystitis / biliary colic, 34 patients were with acute cholecystitis and 16 patients had diagnosis of empyema gallbladder. The mean operative time was 35.3+-14.6 min. Conversion rate to open surgery was 1.2%. Complications included bleeding from cystic artery (n=1) and injury to common hepatic duct (CHD) (n=1). One patient developed port site hernia post operatively. There was no incidence of laparoscopy related complications in surgeon such as pain shoulder, strains on the wrist joint, stress exhaustion and hand-finger joint pain. Conclusion: Sectorisation technique can be used in laparoscopic cholecystectomy in order to avoid the physical constraints of laparoscopic shoulder, hand finger joint pain, tenosynovitis, stress exhaustion, and hand muscle injury without increasing any morbidity to the patients. (author)

  6. Ecological land classification and terrestrial environment effects assessment for the Port Hope and Port Granby projects

    International Nuclear Information System (INIS)

    Taylor, M.; Wittkugel, U.; Kleb, H.

    2006-01-01

    The Ecological Land Classification system was developed to provide a standardized methodology for describing plant communities and wildlife habitat in southern Ontario. The method employs a hierarchical classification system. It can be applied at different levels of accuracy, i.e., at regional, sub-regional, and local scales with an increasing differentiation of vegetation communities. The standardization of the approach permits a comparison of vegetation communities from different sites and an evaluation of the rarity of these communities within the province. Further, the approach facilitates the monitoring of changes in terrestrial communities with time. These characteristics make Ecological Land Classification mapping a useful tool for environmental assessment such as the ones undertaken for the Port Hope and Port Granby Long-Term Waste Management Projects, which were conducted pursuant to the Canadian Environmental Assessment Act 1992. In the context of the Environmental Assessment for the Port Hope and Port Granby Projects, an Ecological Land Classification study was undertaken to characterize the terrestrial environment at regional, local and site levels. Vegetation patches (polygons) were delineated on the basis of air photo interpretation. The individual polygons were then visited for detailed inventory and classified to the most detailed level; that is to the vegetation type. Plant communities were then compared with those listed in the Ontario Natural Heritage Information Centre database to determine their rarity and to determine where they rank as Valued Ecosystem Components. Ecological Land Classification mapping results were used in the assessment of effects to Valued Ecosystem Components. A spatial analysis of the digitized vegetation maps showed the geographic extent of habitat losses and impairments due to various project works and activities. Landscape rehabilitation strategies and concepts were subsequently developed based on Ecological Land

  7. Securing a port's future through Circular Economy: Experiences from the Port of Gävle in contributing to sustainability.

    Science.gov (United States)

    Carpenter, Angela; Lozano, Rodrigo; Sammalisto, Kaisu; Astner, Linda

    2018-03-01

    Ports are an important player in the world, due to their role in global production and distributions systems. They are major intermodal transport hubs, linking the sea to the land. For all ports, a key requirement for commercial and economic viability is to retain ships using them and to remain accessible to those ships. Ports need to find approaches to help them remain open. They must ensure their continued economic viability. At the same time, they face increasing pressure to become more environmentally and socially conscious. This paper examines the approach taken by the Port of Gävle, Sweden, which used contaminated dredged materials to create new land using principles of Circular Economy. The paper demonstrates that using Circular Economy principles can be a viable way of securing a port's future and contributing to its sustainability, and that of the city/region where it operates. Copyright © 2018 Elsevier Ltd. All rights reserved.

  8. Overview video diagnostics for the W7-X stellarator

    Energy Technology Data Exchange (ETDEWEB)

    Kocsis, G., E-mail: kocsis.gabor@wigner.mta.hu [Wigner RCP, RMI, Konkoly Thege 29-33, H-1121 Budapest (Hungary); Baross, T. [Wigner RCP, RMI, Konkoly Thege 29-33, H-1121 Budapest (Hungary); Biedermann, C. [Max-Planck-Institute for Plasma Physics, 17491 Greifswald (Germany); Bodnár, G.; Cseh, G.; Ilkei, T. [Wigner RCP, RMI, Konkoly Thege 29-33, H-1121 Budapest (Hungary); König, R.; Otte, M. [Max-Planck-Institute for Plasma Physics, 17491 Greifswald (Germany); Szabolics, T.; Szepesi, T.; Zoletnik, S. [Wigner RCP, RMI, Konkoly Thege 29-33, H-1121 Budapest (Hungary)

    2015-10-15

    Considering the requirements of the newly built Wendelstein 7-X stellarator a ten-channel overview video diagnostic system was developed and is presently under installation. The system covering the whole torus interior can be used not only to observe the plasma but also to detect irregular operational events which are dangerous for the stellarator itself and to send automatic warning for the machine safety. The ten tangential AEQ ports used by the diagnostic remain under atmospheric pressure, the vacuum/air interface is at the front window located at the plasma side of the AEQ port. The optical vacuum window is protected by a cooled pinhole. The Sensor Module (SM) of the intelligent camera (EDICAM) – developed especially for this purpose – is located directly behind the vacuum window. EDICAM is designed to simultaneously record several regions of interest of its CMOS sensor with different frame rate and to detect various predefined events in real time. The air cooled SM is fixed by a docking mechanism which can preserve the pointing of the view. EDICAM can withstand the magnetic field (∼3 T), the neutron and gamma fluxes expected in the AEQ port. In order to adopt the new features of the video diagnostics system both control and data acquisition and visualization and data processing softwares are developed.

  9. Overview video diagnostics for the W7-X stellarator

    International Nuclear Information System (INIS)

    Kocsis, G.; Baross, T.; Biedermann, C.; Bodnár, G.; Cseh, G.; Ilkei, T.; König, R.; Otte, M.; Szabolics, T.; Szepesi, T.; Zoletnik, S.

    2015-01-01

    Considering the requirements of the newly built Wendelstein 7-X stellarator a ten-channel overview video diagnostic system was developed and is presently under installation. The system covering the whole torus interior can be used not only to observe the plasma but also to detect irregular operational events which are dangerous for the stellarator itself and to send automatic warning for the machine safety. The ten tangential AEQ ports used by the diagnostic remain under atmospheric pressure, the vacuum/air interface is at the front window located at the plasma side of the AEQ port. The optical vacuum window is protected by a cooled pinhole. The Sensor Module (SM) of the intelligent camera (EDICAM) – developed especially for this purpose – is located directly behind the vacuum window. EDICAM is designed to simultaneously record several regions of interest of its CMOS sensor with different frame rate and to detect various predefined events in real time. The air cooled SM is fixed by a docking mechanism which can preserve the pointing of the view. EDICAM can withstand the magnetic field (∼3 T), the neutron and gamma fluxes expected in the AEQ port. In order to adopt the new features of the video diagnostics system both control and data acquisition and visualization and data processing softwares are developed.

  10. NEW ABELISAURID MATERIAL FROM THE UPPER CRETACEOUS (CENOMANIAN OF MOROCCO

    Directory of Open Access Journals (Sweden)

    SIMONE D'ORAZI PORCHETTI

    2011-11-01

    Full Text Available Fragmentary cranial bones of dinosaur origin have been recently recovered from the Kem Kem beds (Upper Cretaceous, Cenomanian of Morocco. They include two incompletely preserved maxillary bones evidencing diagnostic features of abelisaurid theropods. These new finds provide further evidence of Abelisauridae in the Late Cretaceous of Morocco. 

  11. New lidocaine lozenge as topical anesthesia compared to lidocaine viscous oral solution before upper gastrointestinal endoscopy

    DEFF Research Database (Denmark)

    Mogensen, Stine; Treldal, Charlotte; Feldager, Erik

    2012-01-01

    To evaluate the effect and acceptance of a new lidocaine lozenge compared with a lidocaine viscous oral solution as a pharyngeal anesthetic before upper gastrointestinal endoscopy (UGE), a diagnostic procedure commonly performed worldwide during which many patients experience severe discomfort...

  12. [Diagnosis of upper urinary tract tumors. A pending challenge].

    Science.gov (United States)

    Westendarp, M; Laguna, M P; de la Rosette, J J M C

    2014-07-01

    Early diagnosis of upper urinary tract tumors is not easy. The development of endoscopic equipment has expanded the group of patients candidates for minimally invasive treatment. Only by providing accurate tumor staging and grading can clinicians decide which patients should be offered conservative therapies. We need diagnostic methods that allow us to make an early and accurate diagnosis for these lesions, as well as safe follow-up. Our proposal is to present a review of the most used diagnostic method, their features, and future diagnostic tools. The diagnostic arsenal requires further improvement. Only through accurate diagnosis, we will be able to safely provide conservative treatment. Developing new diagnostic techniques seem to move us closer to this goal even more. We propose a working algorithm on the management of these lesions.

  13. Videoendoscopia digestiva superior en el Centro Médico de Diagnóstico de Alta Tecnología "Las Heroínas de Mérida" del estado venezolano de Mérida Upper gastrointestinal video endoscopy at the Diagnostic Medical Center of High Technology "Las heroínas de Mérida" of Mérida state in Venezuela

    Directory of Open Access Journals (Sweden)

    Odalis García Paneque

    2013-02-01

    Full Text Available Se efectuó un estudio descriptivo y transversal de los 1 742 pacientes mayores de 18 años en los que se realizó de forma satisfactoria la videoendoscopia del tracto digestivo superior en el Centro Médico de Diagnóstico de Alta Tecnología "Las Heroínas de Mérida" del Estado Mérida (Venezuela, desde el 2008 hasta el 2011, con vistas a describir los hallazgos a través de dicho procedimiento. En la casuística predominaron el sexo femenino (63,3 % y el grupo etario de 46-61 años, con una edad promedio de 55,8 años; además, 30,6 % de las pruebas resultaron normales. El dolor epigástrico (48,6 %, la dispepsia (43,5 % y el reflujo gastroesofágico (8,6 % fueron las principales causas de remisión, en tanto la gastritis (32,4 % constituyó el diagnóstico endoscópico más frecuente, específicamente sus variedades eritematosa y eritemato-erosiva, con 66,0 y 13,0 %, respectivamente. Del total, 10 pacientes presentaron cáncer gástrico y 9, cáncer esofágico. Se pudo concluir que el procedimiento permitió el diagnóstico preciso de las enfermedades del tracto digestivo superior, así como una atención terapéutica adecuada.A descriptive and cross-sectional study was conducted in 1 742 patients over 15 years, in whom the video endoscopy of upper gastrointestinal tract was successfully performed at the Diagnostic Medical Center of High Technology "Las Heroínas de Mérida" of Mérida state (Venezuela, from 2008 to 2011, with the purpose of describing the findings through this procedure. Female sex (63.3% and age group of 46-61 years with a mean age of 55.8 years predominated in the case material, and 30.6% of the tests were normal. Epigastric pain (48.6%, dyspepsia (43.5% and gastroesophageal reflux (8.6% were the main reasons for referrals, while gastritis (32.4% constituted the most frequent endoscopic diagnosis, specifically its erythematous and erythematous-erosive varieties, with 66.0 and 13.0%, respectively. Of the total, 10

  14. [Single-port laparoscopic cholecystectomy: advantages and disadvantages].

    Science.gov (United States)

    Alekberzade, A V; Lipnitsky, E M; Krylov, N N; Sundukov, I V; Badalov, D A

    2016-01-01

    To analyze the outcomes of single-port laparoscopic cholecystectomy. Early and long-term postoperative period has been analyzed in 240 patients who underwent laparoscopic cholecystectomy (LCE) including 120 cases of single-port technique and 120 cases of four-port technique. Both groups were compared in surgical time, pain syndrome severity (visual analog scale), need for analgesics, postoperative complications, hospital-stay, daily activity recovery and return to physical work, patients' satisfaction of surgical results and their aesthetic effect. It was revealed that single-port LCE is associated with lower severity of postoperative pain, quick recovery of daily activity and return to physical work, high satisfaction of surgical results and their aesthetic effect compared with four-port LCE. Disadvantages of single-port LCE include longer duration of surgery, high incidence of postoperative umbilical hernia. However hernia was predominantly observed during the period of surgical technique development. Further studies to standardize, evaluate the safety and benefits of single-port LCE are necessary.

  15. Comparison of differences between ports for radioactive material transport

    International Nuclear Information System (INIS)

    Massey, C.D.; Wheeler, T.A.; Yoshimura, H.R.

    1994-01-01

    Recent controversy and litigation over the import/export of radioactive materials into and out of the United States via United States ports has centered on differences between ports, especially differences in surrounding population densities, and also whether reliance on one or a few ports poses unacceptable risks for these ports and the surrounding populations. This study examines the results of risk analyses from several recent environmental assessments dealing with import/export of various types of radioactive materials ranging from uranium hexafluoride to spent nuclear fuel. Since an intermodal transfer is always involved, the maritime and intermodal transportation is broken down into its component activities and segments; each is determined separately. The results indicate that most of the potential exposure occurs during routine handling of packages during intermodal transfer. Since handling of containerized cargo is highly standardized at ports around the world, differences between ports are of secondary importance. The risks associated with any overland transport from port to inland destination are primarily a function of distance for a given package type

  16. Ports: Definition and study of types, sizes and business models

    Directory of Open Access Journals (Sweden)

    Ivan Roa

    2013-09-01

    Full Text Available Purpose: In the world today there are thousands of port facilities of different types and sizes, competing to capture some market share of freight by sea, mainly. This article aims to determine the type of port and the most common size, in order to find out which business model is applied in that segment and what is the legal status of the companies of such infrastructure.Design/methodology/approach: To achieve this goal, we develop a research on a representative sample of 800 ports worldwide, which manage 90% of the containerized port loading. Then you can find out the legal status of the companies that manage them.Findings: The results indicate a port type and a dominant size, which are mostly managed by companies subject to a concession model.Research limitations/implications: In this research, we study only those ports that handle freight (basically containerized, ignoring other activities such as fishing, military, tourism or recreational.Originality/value: This is an investigation to show that the vast majority of the studied segment port facilities are governed by a similar corporate model and subject to pressure from the markets, which increasingly demand efficiency and service. Consequently, we tend to concession terminals to private operators in a process that might be called privatization, but in the strictest sense of the term, is not entirely realistic because the ownership of the land never ceases to be public

  17. Two-port robotic hysterectomy: a novel approach.

    Science.gov (United States)

    Moawad, Gaby N; Tyan, Paul; Khalil, Elias D Abi

    2018-03-24

    The objective of the study was to demonstrate a novel technique for two-port robotic hysterectomy with a particular focus on the challenging portions of the procedure. The study is designed as a technical video, showing step-by-step a two-port robotic hysterectomy approach (Canadian Task Force classification level III). IRB approval was not required for this study. The benefits of minimally invasive surgery for gynecological pathology have been clearly documented in multiple studies. Patients had fewer medical and surgical complications postoperatively, better cosmesis and quality of life. Most gynecological surgeons require 3-5 ports for the standard gynecological procedure. Even though the minimally invasive multiport system provides an excellent safety profile, multiple incisions are associated with a greater risk for morbidity including infection, pain, and hernia. In the past decade, various new methods have emerged to minimize the number of ports used in gynecological surgery. The interventions employed were a two-port robotic hysterectomy, using a camera port plus one robotic arm, with a focus on salpingectomy and cuff closure. We describe a transvaginal and a transabdominal approach for salpingectomy and a novel method for cuff closure. The transvaginal and transabdominal techniques for salpingectomy for two-port robotic-assisted hysterectomy provide excellent tension and exposure for a safe procedure without the need for an extra port. We also describe a transvaginal technique to place the vaginal cuff on tension during closure. With the necessary set of skills on a carefully chosen patient, two-port robotic-assisted total laparoscopic hysterectomy is a feasible procedure.

  18. Free Port of Vladivostok: Development Conditions, Prospects, Risks

    Directory of Open Access Journals (Sweden)

    Elena Viktorovna Krasova

    2015-12-01

    Full Text Available One of the priority directions of Russia’s state policy with regard to territories’ development is the development of the Far Eastern region. The free port of Vladivostok is one of the key projects that are currently being implemented in the southern part of Primorsky Krai and they focus on boosting the socio-economic development of Vladivostok city, Primorsky Krai and the Far Eastern region as a whole. The goal of this research is to consider the conceptual issues of the free port of Vladivostok, to outline the conditions and prospects of its operation and identify risks associated with its future development. The article defines the modern concept of “free port”, characterizes historical experience of the “free port” regime in Vladivostok in the end of the 19th century, substantiates the strategic importance of using the free port of Vladivostok as a tool of intensive growth of Russian Far Eastern territories. The article also discloses the essence of the free port of Vladivostok as a means to promote free entrepreneurship, which is used to increase freight traffic through the port of Vladivostok, increase foreign trade, attract new investments, create new industries and develop the port’s infrastructure. The article provides a review of the main tax benefits and perspectives of the free port of Vladivostok in terms of the gross regional product formation. Analyzing the mechanisms of effective functioning of the free port of Vladivostok, the authors identify the short-term (mid-term and long-term priorities and operational risks for the free port of Vladivostok. The article also touches upon some issues concerning the response of some foreign countries to the creation of the free port of Vladivostok

  19. Lectures in plasma diagnostics

    International Nuclear Information System (INIS)

    Hutchinson, I.H.

    1990-06-01

    This paper discusses the following topics on plasma diagnostics: Electric probes in flowing and magnetized plasmas; Electron cyclotron emission absorption; Magnetic diagnostics; Spectroscopy; and Thomson Scattering

  20. Upper urinary tract tumors

    DEFF Research Database (Denmark)

    Gandrup, Karen L; Nordling, Jørgen; Balslev, Ingegerd

    2014-01-01

    BACKGROUND: Computed tomography urography (CTU) is used widely in the work-up of patients with symptoms of urinary tract lesions. Preoperative knowledge of whether a tumor is invasive or non-invasive is important for the choice of surgery. So far there are no studies about the distinction...... of invasive and non-invasive tumors in ureter and renal pelvis based on the enhancement measured with Hounsfield Units. PURPOSE: To examine the value of CTU using split-bolus technique to distinguish non-invasive from invasive urothelial carcinomas in the upper urinary tract. MATERIAL AND METHODS: Patients...... obtained at CTU could distinguish between invasive and non-invasive lesions. No patients had a CTU within the last year before the examination that resulted in surgery. CONCLUSION: A split-bolus CTU cannot distinguish between invasive and non-invasive urothelial tumors in the upper urinary tract...