  1. A Diagnostic Ultrasound Imaging System

    International Nuclear Information System (INIS)

    Lee, Seong Woo

    1999-01-01

    The ability to see the internal organs of the human body in a noninvasive way is a powerful diagnostic tool of modern medicine. Among these imaging modalities such as X-ray, MRI, and ultrasound. MRI and ultrasound are presenting much less risk of undesirable damage of both patient and examiner. In fact, no deleterious effects have been reported as a result of clinical examination by using MRI and ultrasound diagnostic equipment. As a result, their market volume has been rapidly increased. MRI has a good resolution. but there are a few disadvantages such as high price. non-real-time imaging capability. and expensive diagnostic cost. On the other hand, the ultrasound imaging system has inherently poor resolution as compared with X-ray and MRI. In spite of its poor resolution, the ultrasound diagnostic equipment is lower in price and has an ability of real-time imaging as compared with the others. As a result, the ultrasound imaging system has become general and essential modality for imaging the internal organs of human body. In this review various researches and developments to enhance the resolution of the ultrasound images are explained and future trends of the ultrasound imaging technology are described

  2. Clinical diagnostic ultrasound

    International Nuclear Information System (INIS)

    Barnett, E.; Morley, P.

    1986-01-01

    This textbook on diagnostic ultrasound covers the main systems, with emphasis being placed on the clinical application of diagnostic ultrasound in everyday practice. It provides not only a textbook for postgraduates (particularly FRCR candidates), but also a reference work for practitioners of clinical ultrasound and clinicians generally

  3. WE-AB-206-01: Diagnostic Ultrasound Imaging Quality Assurance

    Energy Technology Data Exchange (ETDEWEB)

    Zagzebski, J. [University of Wisconsin (United States)

    2016-06-15

    The involvement of medical physicists in diagnostic ultrasound imaging service is increasing due to QC and accreditation requirements. The goal of this ultrasound hands-on workshop is to demonstrate quality control (QC) testing in diagnostic ultrasound and to provide updates in ACR ultrasound accreditation requirements. The first half of this workshop will include two presentations reviewing diagnostic ultrasound QA/QC and ACR ultrasound accreditation requirements. The second half of the workshop will include live demonstrations of basic QC tests. An array of ultrasound testing phantoms and ultrasound scanners will be available for attendees to learn diagnostic ultrasound QC in a hands-on environment with live demonstrations and on-site instructors. The targeted attendees are medical physicists in diagnostic imaging. Learning Objectives: Gain familiarity with common elements of a QA/QC program for diagnostic ultrasound imaging dentify QC tools available for testing diagnostic ultrasound systems and learn how to use these tools Learn ACR ultrasound accreditation requirements Jennifer Walter is an employee of American College of Radiology on Ultrasound Accreditation.

  4. WE-AB-206-01: Diagnostic Ultrasound Imaging Quality Assurance

    International Nuclear Information System (INIS)

    Zagzebski, J.

    2016-01-01

    The involvement of medical physicists in diagnostic ultrasound imaging service is increasing due to QC and accreditation requirements. The goal of this ultrasound hands-on workshop is to demonstrate quality control (QC) testing in diagnostic ultrasound and to provide updates in ACR ultrasound accreditation requirements. The first half of this workshop will include two presentations reviewing diagnostic ultrasound QA/QC and ACR ultrasound accreditation requirements. The second half of the workshop will include live demonstrations of basic QC tests. An array of ultrasound testing phantoms and ultrasound scanners will be available for attendees to learn diagnostic ultrasound QC in a hands-on environment with live demonstrations and on-site instructors. The targeted attendees are medical physicists in diagnostic imaging. Learning Objectives: Gain familiarity with common elements of a QA/QC program for diagnostic ultrasound imaging dentify QC tools available for testing diagnostic ultrasound systems and learn how to use these tools Learn ACR ultrasound accreditation requirements Jennifer Walter is an employee of American College of Radiology on Ultrasound Accreditation.

  5. MO-AB-210-00: Diagnostic Ultrasound Imaging Quality Control and High Intensity Focused Ultrasound Therapy Hands-On Workshop

    International Nuclear Information System (INIS)

    2015-01-01

    The goal of this ultrasound hands-on workshop is to demonstrate advancements in high intensity focused ultrasound (HIFU) and to demonstrate quality control (QC) testing in diagnostic ultrasound. HIFU is a therapeutic modality that uses ultrasound waves as carriers of energy. HIFU is used to focus a beam of ultrasound energy into a small volume at specific target locations within the body. The focused beam causes localized high temperatures and produces a well-defined regions of necrosis. This completely non-invasive technology has great potential for tumor ablation and targeted drug delivery. At the workshop, attendees will see configurations, applications, and hands-on demonstrations with on-site instructors at separate stations. The involvement of medical physicists in diagnostic ultrasound imaging service is increasing due to QC and accreditation requirements. At the workshop, an array of ultrasound testing phantoms and ultrasound scanners will be provided for attendees to learn diagnostic ultrasound QC in a hands-on environment with live demonstrations of the techniques. Target audience: Medical physicists and other medical professionals in diagnostic imaging and radiation oncology with interest in high-intensity focused ultrasound and in diagnostic ultrasound QC. Learning Objectives: Learn ultrasound physics and safety for HIFU applications through live demonstrations Get an overview of the state-of-the art in HIFU technologies and equipment Gain familiarity with common elements of a quality control program for diagnostic ultrasound imaging Identify QC tools available for testing diagnostic ultrasound systems and learn how to use these tools List of supporting vendors for HIFU and diagnostic ultrasound QC hands-on workshop: Philips Healthcare Alpinion Medical Systems Verasonics, Inc Zonare Medical Systems, Inc Computerized Imaging Reference Systems (CIRS), Inc. GAMMEX, Inc., Cablon Medical BV Steffen Sammet: NIH/NCI grant 5R25CA132822, NIH/NINDS grant 5R25NS

  6. MO-AB-210-00: Diagnostic Ultrasound Imaging Quality Control and High Intensity Focused Ultrasound Therapy Hands-On Workshop

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2015-06-15

    The goal of this ultrasound hands-on workshop is to demonstrate advancements in high intensity focused ultrasound (HIFU) and to demonstrate quality control (QC) testing in diagnostic ultrasound. HIFU is a therapeutic modality that uses ultrasound waves as carriers of energy. HIFU is used to focus a beam of ultrasound energy into a small volume at specific target locations within the body. The focused beam causes localized high temperatures and produces a well-defined regions of necrosis. This completely non-invasive technology has great potential for tumor ablation and targeted drug delivery. At the workshop, attendees will see configurations, applications, and hands-on demonstrations with on-site instructors at separate stations. The involvement of medical physicists in diagnostic ultrasound imaging service is increasing due to QC and accreditation requirements. At the workshop, an array of ultrasound testing phantoms and ultrasound scanners will be provided for attendees to learn diagnostic ultrasound QC in a hands-on environment with live demonstrations of the techniques. Target audience: Medical physicists and other medical professionals in diagnostic imaging and radiation oncology with interest in high-intensity focused ultrasound and in diagnostic ultrasound QC. Learning Objectives: Learn ultrasound physics and safety for HIFU applications through live demonstrations Get an overview of the state-of-the art in HIFU technologies and equipment Gain familiarity with common elements of a quality control program for diagnostic ultrasound imaging Identify QC tools available for testing diagnostic ultrasound systems and learn how to use these tools List of supporting vendors for HIFU and diagnostic ultrasound QC hands-on workshop: Philips Healthcare Alpinion Medical Systems Verasonics, Inc Zonare Medical Systems, Inc Computerized Imaging Reference Systems (CIRS), Inc. GAMMEX, Inc., Cablon Medical BV Steffen Sammet: NIH/NCI grant 5R25CA132822, NIH/NINDS grant 5R25NS

  7. Ultrasound diagnostics of thyroid diseases

    International Nuclear Information System (INIS)

    Kharchenko, Vladimir P.; Kotlyarov, Peter M.; Mogutov, Mikhail S.; Sencha, Alexander N.; Patrunov, Yury N.; Belyaev, Denis V.; Alexandrov, Yury K.

    2010-01-01

    This book is based on the authors' extensive practical experience in the use of modern ultrasound, and other radiological methods, in the diagnosis of thyroid diseases. The authors have analyzed more than 100,000 ultrasound examinations performed between 1995 and 2008 in patients with thyroid and parathyroid disease, as well as many thousands of diagnostic and therapeutic ultrasound-guided minimally invasive procedures. The opening chapters include discussion of current ultrasound techniques, pitfalls, and the specifics of ultrasound examination of the thyroid in children. Detailed attention is then devoted to findings in the normal thyroid and in the presence of diffuse and focal changes. Further chapters focus on such topics as ultrasound examination after thyroid surgery and ultrasound diagnosis of parathyroid disease, recurrent goiter, and neck masses. Ultrasound-guided minimally invasive techniques, such as fine-needle aspiration biopsy, percutaneous laser ablation, and ethanol and glucocorticoid injections, are considered in depth. This up-to-date and richly illustrated book will interest and assist specialists in ultrasound diagnostics, radiologists, endocrinologists, and neck surgeons. (orig.)

  8. Safety of Medical Diagnostic Ultrasound

    International Nuclear Information System (INIS)

    Breyer, B.

    1998-01-01

    Large numbers of people (both sick and healthy) are routinely exposed to ultrasound waves. We shall discuss wave parameters and scanner properties that are relevant to the safety aspect. This includes central pulse frequency, pulse length, intensity (ISPTA and others), focusing, pulse repetition frequency, pulse pressure, etc. Since the transmitted ultrasound power has steadily been increasing during the last two decades, the problems are becoming more serious with time. Doppler methods have gained importance and 'popularity, which additionally increases ultrasound power requirements since the reflectivity of red blood cells is so small that the backscattered pressure is about 100 times less than that from soft tissue structures in the body. Main mechanisms that can potentially present hazard are heating and cavitation. The basic parameter used to assess thermal hazard is ISPTA and the optimal predictor of cavitation hazard is the peak rarefractional pressure. The hazard of heating-up can be summarized in saying that temperatures up to 38.5 o C are safe, while temperatures above 41 o C are definitely not. Care must be taken to stay within the safe zone. However, there does not exist a confirmed report of any type of hazardous effects on humans using intensities presently applied in diagnostic ultrasound scanners. Taking this into account, various international bodies have put limits to the application of ultrasound, which is best summarized in the FDA (USA) regulation that diagnostic apparatus may have an output of maximally 720 mW/cm 2 (derated) provided thermal and mechanical properties are indicated (onscreen) by properly defined Thermal Indices (TI) and Mechanical Index (MI). These aspects shall be discussed in some detail. We shall give the rules for the operator to apply ultrasound with minimal hazard. The general conclusion is that diagnostic ultrasound, as presently known, may be used whenever a qualified expert expects essential medical benefit for the

  9. Machine Learning in Ultrasound Computer-Aided Diagnostic Systems: A Survey.

    Science.gov (United States)

    Huang, Qinghua; Zhang, Fan; Li, Xuelong

    2018-01-01

    The ultrasound imaging is one of the most common schemes to detect diseases in the clinical practice. There are many advantages of ultrasound imaging such as safety, convenience, and low cost. However, reading ultrasound imaging is not easy. To support the diagnosis of clinicians and reduce the load of doctors, many ultrasound computer-aided diagnosis (CAD) systems are proposed. In recent years, the success of deep learning in the image classification and segmentation led to more and more scholars realizing the potential of performance improvement brought by utilizing the deep learning in the ultrasound CAD system. This paper summarized the research which focuses on the ultrasound CAD system utilizing machine learning technology in recent years. This study divided the ultrasound CAD system into two categories. One is the traditional ultrasound CAD system which employed the manmade feature and the other is the deep learning ultrasound CAD system. The major feature and the classifier employed by the traditional ultrasound CAD system are introduced. As for the deep learning ultrasound CAD, newest applications are summarized. This paper will be useful for researchers who focus on the ultrasound CAD system.

  10. Machine Learning in Ultrasound Computer-Aided Diagnostic Systems: A Survey

    Directory of Open Access Journals (Sweden)

    Qinghua Huang

    2018-01-01

    Full Text Available The ultrasound imaging is one of the most common schemes to detect diseases in the clinical practice. There are many advantages of ultrasound imaging such as safety, convenience, and low cost. However, reading ultrasound imaging is not easy. To support the diagnosis of clinicians and reduce the load of doctors, many ultrasound computer-aided diagnosis (CAD systems are proposed. In recent years, the success of deep learning in the image classification and segmentation led to more and more scholars realizing the potential of performance improvement brought by utilizing the deep learning in the ultrasound CAD system. This paper summarized the research which focuses on the ultrasound CAD system utilizing machine learning technology in recent years. This study divided the ultrasound CAD system into two categories. One is the traditional ultrasound CAD system which employed the manmade feature and the other is the deep learning ultrasound CAD system. The major feature and the classifier employed by the traditional ultrasound CAD system are introduced. As for the deep learning ultrasound CAD, newest applications are summarized. This paper will be useful for researchers who focus on the ultrasound CAD system.

  11. Diagnostic significance of ultrasound in dermatology

    OpenAIRE

    Stojanović Slobodan; Poljački Mirjana N.; Roš Tatjana

    2002-01-01

    Introduction Utilization of 20 MHz ultrasound probes provided application of ultrasound in dermatology - dermatosonography. As a diagnostic tool, ultrasound was first registered in the early fifties of the past century. Great progress of dermatosonography occurred in the mid-nineties with introduction of the first 20 MHz scanner. Methods of ultrasonography in dermatology Several methods of ultrasonography have been developed: method A, method B, scanning C method and Doppler ultrasound. They ...

  12. Computer-aided diagnostic system for detection of Hashimoto thyroiditis on ultrasound images from a Polish population.

    Science.gov (United States)

    Acharya, U Rajendra; Sree, S Vinitha; Krishnan, M Muthu Rama; Molinari, Filippo; Zieleźnik, Witold; Bardales, Ricardo H; Witkowska, Agnieszka; Suri, Jasjit S

    2014-02-01

    Computer-aided diagnostic (CAD) techniques aid physicians in better diagnosis of diseases by extracting objective and accurate diagnostic information from medical data. Hashimoto thyroiditis is the most common type of inflammation of the thyroid gland. The inflammation changes the structure of the thyroid tissue, and these changes are reflected as echogenic changes on ultrasound images. In this work, we propose a novel CAD system (a class of systems called ThyroScan) that extracts textural features from a thyroid sonogram and uses them to aid in the detection of Hashimoto thyroiditis. In this paradigm, we extracted grayscale features based on stationary wavelet transform from 232 normal and 294 Hashimoto thyroiditis-affected thyroid ultrasound images obtained from a Polish population. Significant features were selected using a Student t test. The resulting feature vectors were used to build and evaluate the following 4 classifiers using a 10-fold stratified cross-validation technique: support vector machine, decision tree, fuzzy classifier, and K-nearest neighbor. Using 7 significant features that characterized the textural changes in the images, the fuzzy classifier had the highest classification accuracy of 84.6%, sensitivity of 82.8%, specificity of 87.0%, and a positive predictive value of 88.9%. The proposed ThyroScan CAD system uses novel features to noninvasively detect the presence of Hashimoto thyroiditis on ultrasound images. Compared to manual interpretations of ultrasound images, the CAD system offers a more objective interpretation of the nature of the thyroid. The preliminary results presented in this work indicate the possibility of using such a CAD system in a clinical setting after evaluating it with larger databases in multicenter clinical trials.

  13. Fetal stimulation by pulsed diagnostic ultrasound.

    Science.gov (United States)

    Fatemi, M; Ogburn, P L; Greenleaf, J F

    2001-08-01

    To show that pulsed ultrasound from a clinical ultrasonic imaging system can stimulate the fetus. Stimulation is defined mainly as increased fetal gross body movements in response to excitation. Fetuses of a group of 9 volunteer women (mean gestational age, 33.37 weeks; range, 25-40 weeks) were evaluated for body movement under 3 different conditions: (1) control, with no ultrasound exposure; (2) ultrasound in continuous wave Doppler mode; and (3) pulsed ultrasound in pulsed Doppler and B modes. A conventional external fetal monitor, with negligible ultrasonic output, was used to monitor fetal gross body motions. After an initial rest period of 3 minutes with 1 or no fetal motion, fetuses were monitored for an additional 3 minutes under the exposure criterion defined for each condition. Resulting fetal motions under the 3 conditions were compared using the Wilcoxon signed rank test. The test showed that fetuses moved significantly more frequently under condition 3 (mean +/- SD, 3.43 +/- 1.93 movements per minute) than under condition 1 (0.40 +/- 7.33 movements per minute) or condition 2 (0.63 +/- 7.67 movements per minute); P = .004 and .016, respectively. Fetal movements under conditions 1 and 2 did not differ significantly. Diagnostic ultrasound may stimulate fetal body motion.

  14. Diagnostic ultrasound use in physiotherapy, emergency medicine, and anaesthesiology

    Energy Technology Data Exchange (ETDEWEB)

    McKiernan, Sharmaine [School of Health Sciences, University of Newcastle, Callagham, NSW 2308 (Australia)], E-mail: sharmaine.mckiernan@newcastle.edu.au; Chiarelli, Pauline; Warren-Forward, Helen [School of Health Sciences, University of Newcastle, Callagham, NSW 2308 (Australia)

    2010-05-15

    Background: Diagnostic ultrasound is traditionally and extensively used within the radiology department. However in recent years its use has expanded outside this traditional area into health professions such as physiotherapy, emergency medicine and anaesthesiology. Purpose: The radiology community needs to be aware of the expansion of use of diagnostic ultrasound. This article starts this exploration in the health professions mentioned, however it is acknowledged that diagnostic ultrasound use goes beyond what is covered in this article. As diagnostic ultrasound is a user dependant modality and the outcome of an examination is largely influenced by the skill and experience of the operator, the radiology community should take a guiding role in its use, training and protocol development for health professionals. Method: This article explores the literature on the use of diagnostic ultrasound within physiotherapy, emergency medicine and anaesthesiology. Literature was searched for on the databases Medline, Cinahl and Embase. Results: Diagnostic ultrasound is being used in health professions such as physiotherapy, where it is being used to provide biofeedback to patients on contraction of abdominal and pelvic floor muscles; emergency medicine, for the investigation of free fluid within the abdomen of a trauma patient and anaesthesiology, for the placement of catheters and nerve blocks. Conclusion: As members of the radiology community are considered experts in the field, they need to take the lead to guide and mentor the other health professionals who are now using the modality. To be able to achieve this they must have an understanding of what these professions are using the modality for.

  15. Diagnostic ultrasound use in physiotherapy, emergency medicine, and anaesthesiology

    International Nuclear Information System (INIS)

    McKiernan, Sharmaine; Chiarelli, Pauline; Warren-Forward, Helen

    2010-01-01

    Background: Diagnostic ultrasound is traditionally and extensively used within the radiology department. However in recent years its use has expanded outside this traditional area into health professions such as physiotherapy, emergency medicine and anaesthesiology. Purpose: The radiology community needs to be aware of the expansion of use of diagnostic ultrasound. This article starts this exploration in the health professions mentioned, however it is acknowledged that diagnostic ultrasound use goes beyond what is covered in this article. As diagnostic ultrasound is a user dependant modality and the outcome of an examination is largely influenced by the skill and experience of the operator, the radiology community should take a guiding role in its use, training and protocol development for health professionals. Method: This article explores the literature on the use of diagnostic ultrasound within physiotherapy, emergency medicine and anaesthesiology. Literature was searched for on the databases Medline, Cinahl and Embase. Results: Diagnostic ultrasound is being used in health professions such as physiotherapy, where it is being used to provide biofeedback to patients on contraction of abdominal and pelvic floor muscles; emergency medicine, for the investigation of free fluid within the abdomen of a trauma patient and anaesthesiology, for the placement of catheters and nerve blocks. Conclusion: As members of the radiology community are considered experts in the field, they need to take the lead to guide and mentor the other health professionals who are now using the modality. To be able to achieve this they must have an understanding of what these professions are using the modality for.

  16. Diagnostic Ultrasound in Colorectal Cancer

    DEFF Research Database (Denmark)

    Rafaelsen, Søren Rafael

    2014-01-01

    SUMMARYBackground and purpose Colorectal cancer is a common disease in Denmark with considerable morbidity and mortality. Although survival in recent years has improved, Denmark still has the lowest 5-year survival compared to the other Nordic countries. The treatment of patients depends on local...... the potential to contribute to the staging of colorectal cancer. The purpose of these studies was to determine the usefulness of ultrasound diagnostics in patients with colorectal cancer.The purpose of the TRUS studies was to compare staging of rectal carcinomas using digital rectal exploration...... of 295 patients with primary colorectal cancer we found a sensitivity of preoperative ultrasound, surgical exploration, and intraoperative ultrasound of 70%, 84%, and 97%, respectively, based on a patient-by-patient comparison (p

  17. Quality control culture of diagnostic ultrasound parameters

    International Nuclear Information System (INIS)

    Andam, A.A.B; Addison, E.C.K.; Aggry-Smith, S.; Nani, E.K.

    2003-01-01

    A phantom, consisting of two phases, has been designed and constructed to mimic the human body. The phase one phantom was designed to mimic a a surface lesion in the human body and the phase two phantom designed to mimic a section of the whole body. Ultrasound scans of the phantom were acquired for various material in the phantom at six hospitals in Kumasi, Ghana. A linear array transducer with parallel beams having a convex probe and a 3.5 MHz ultrasound frequency were used to carry out the experiment. It was observed that the depth of penetration of ultrasound, which constitutes the maximum depth of visualization or sensitivity, is determined by the frequency of the transducer, the attenuation of the medium being imaged and the system settings. Uniformity and linearity of the machines investigated were found to be within clinically acceptable standards. Spatial resolution, comprising axial and lateral resolutions, was observed to be satisfactory for the machines tested. It was observed that lateral resolution improved with the narrowing of the beam width. The ultrasound scanners at the selected hospitals were found to be operating at the expected level of performance. This work highlights the importance of putting in place a locally based mechanism for quality control of diagnostic ultrasound machines (author)

  18. Review of Safety of Diagnostic Ultrasound in Medical Practice ...

    African Journals Online (AJOL)

    In Nigeria, there is a dearth of scientific literature about the safety of ultrasound as a diagnostic modality. Because of its low cost, real-time image display and lack of evidence of bio-effects, ultrasound is a fast growing imaging modality. The impact of ultrasound in the care of women and children is most obvious. Information ...

  19. Diagnostic ultrasound in pregnancy - ethical problems

    International Nuclear Information System (INIS)

    Sande, H.A.

    1991-01-01

    Foetal diagnostics has changed prenatal checkups beyond the point of no return. The practice of offering ultrasound screening involves great responsibility. Routine ultrasound screening requires a high level of competency. Four main ethical issues are discussed; life or death, malformations, the foetus as patient, and the feotus as donor. Other issues discussed are verifying the diagnosis of death, how to inform the parents, procedures in connection with pathological findings, procedures in connection with stillbirth, and the legal rights of the foetus, as well as three recommendations focussing on the above-mentioned issues. 9 refs

  20. Enhanced ultrasound for advanced diagnostics, ultrasound tomography for volume limb imaging and prosthetic fitting

    Science.gov (United States)

    Anthony, Brian W.

    2016-04-01

    Ultrasound imaging methods hold the potential to deliver low-cost, high-resolution, operator-independent and nonionizing imaging systems - such systems couple appropriate algorithms with imaging devices and techniques. The increasing demands on general practitioners motivate us to develop more usable and productive diagnostic imaging equipment. Ultrasound, specifically freehand ultrasound, is a low cost and safe medical imaging technique. It doesn't expose a patient to ionizing radiation. Its safety and versatility make it very well suited for the increasing demands on general practitioners, or for providing improved medical care in rural regions or the developing world. However it typically suffers from sonographer variability; we will discuss techniques to address user variability. We also discuss our work to combine cylindrical scanning systems with state of the art inversion algorithms to deliver ultrasound systems for imaging and quantifying limbs in 3-D in vivo. Such systems have the potential to track the progression of limb health at a low cost and without radiation exposure, as well as, improve prosthetic socket fitting. Current methods of prosthetic socket fabrication remain subjective and ineffective at creating an interface to the human body that is both comfortable and functional. Though there has been recent success using methods like magnetic resonance imaging and biomechanical modeling, a low-cost, streamlined, and quantitative process for prosthetic cup design and fabrication has not been fully demonstrated. Medical ultrasonography may inform the design process of prosthetic sockets in a more objective manner. This keynote talk presents the results of progress in this area.

  1. Errors and mistakes in breast ultrasound diagnostics

    Directory of Open Access Journals (Sweden)

    Wiesław Jakubowski

    2012-09-01

    Full Text Available Sonomammography is often the first additional examination performed in the diagnostics of breast diseases. The development of ultrasound imaging techniques, particularly the introduction of high frequency transducers, matrix transducers, harmonic imaging and finally, elastography, influenced the improvement of breast disease diagnostics. Neverthe‑ less, as in each imaging method, there are errors and mistakes resulting from the techni‑ cal limitations of the method, breast anatomy (fibrous remodeling, insufficient sensitivity and, in particular, specificity. Errors in breast ultrasound diagnostics can be divided into impossible to be avoided and potentially possible to be reduced. In this article the most frequently made errors in ultrasound have been presented, including the ones caused by the presence of artifacts resulting from volumetric averaging in the near and far field, artifacts in cysts or in dilated lactiferous ducts (reverberations, comet tail artifacts, lateral beam artifacts, improper setting of general enhancement or time gain curve or range. Errors dependent on the examiner, resulting in the wrong BIRADS‑usg classification, are divided into negative and positive errors. The sources of these errors have been listed. The methods of minimization of the number of errors made have been discussed, includ‑ ing the ones related to the appropriate examination technique, taking into account data from case history and the use of the greatest possible number of additional options such as: harmonic imaging, color and power Doppler and elastography. In the article examples of errors resulting from the technical conditions of the method have been presented, and those dependent on the examiner which are related to the great diversity and variation of ultrasound images of pathological breast lesions.

  2. Combined Scanning Confocal Ultrasound Diagnostic and Treatment System for Bone Quality Assessment and Fracture Healing

    Data.gov (United States)

    National Aeronautics and Space Administration — The objectives of this study are to develop a combined diagnostic and treatment ultrasound technology for early prediction of bone disorder and guided acceleration...

  3. The Diagnostic Value of Pelvic Ultrasound in Girls with Central Precocious Puberty.

    Science.gov (United States)

    Lee, Sang Heon; Joo, Eun Young; Lee, Ji-Eun; Jun, Yong-Hoon; Kim, Mi-Young

    2016-01-01

    The gonadotropin-releasing hormone (GnRH) stimulation test is the gold standard for differentiating central precocious puberty (CPP) from exaggerated thelarche (ET). Because of this test's limitations, previous studies have clarified the clinical and laboratory factors that predict CPP. The present study investigated the early diagnostic significance of pelvic ultrasound in girls with CPP. The GnRH stimulation test and pelvic ultrasound were performed between March 2007 and February 2015 in 192 girls (aged values in pelvic ultrasound for differentiating between CPP and ET. Pelvic ultrasound should be combined with clinical and laboratory tests to maximize its diagnostic value for CPP.

  4. Pulmonary Capillary Hemorrhage Induced by Different Imaging Modes of Diagnostic Ultrasound.

    Science.gov (United States)

    Miller, Douglas L; Dong, Zhihong; Dou, Chunyan; Raghavendran, Krishnan

    2018-05-01

    The induction of pulmonary capillary hemorrhage (PCH) is a well-established non-thermal biological effect of pulsed ultrasound in animal models. Typically, research has been done using laboratory pulsed ultrasound systems with a fixed beam and, recently, by B-mode diagnostic ultrasound. In this study, a GE Vivid 7 Dimension ultrasound machine with 10 L linear array probe was used at 6.6 MHz to explore the relative PCH efficacy of B-mode imaging, M-mode (fixed beam), color angio mode Doppler imaging and pulsed Doppler mode (fixed beam). Anesthetized rats were scanned in a warmed water bath, and thresholds were determined by scanning at different power steps, 2 dB apart, in different groups of six rats. Exposures were performed for 5 min, except for a 15-s M-mode group. Peak rarefactional pressure amplitude thresholds were 1.5 MPa for B-mode and 1.1 MPa for angio Doppler mode. For the non-scanned modes, thresholds were 1.1 MPa for M-mode and 0.6 MPa for pulsed Doppler mode with its relatively high duty cycle (7.7 × 10 -3 vs. 0.27 × 10 -3 for M-mode). Reducing the duration of M-mode to 15 s (from 300 s) did not significantly reduce PCH (area, volume or depth) for some power settings, but the threshold was increased to 1.4 MPa. Pulmonary sonographers should be aware of this unique adverse bio-effect of diagnostic ultrasound and should consider reduced on-screen mechanical index settings for potentially vulnerable patients. Copyright © 2018 World Federation for Ultrasound in Medicine and Biology. Published by Elsevier Inc. All rights reserved.

  5. Exposure criteria for medical diagnostic ultrasound: 1, Criteria based on thermal mechanisms

    International Nuclear Information System (INIS)

    1992-01-01

    A previous report (NCRP, 1983) contains a comprehensive review of biological effects and mechanisms of action of ultrasound and an analysis of their implications for medical ultrasound. This Report presents background material for a scientifically-based approach to safety assessment of ultrasound. It is intended to help the medical community take advantage of new developments, while maintaining the excellent safety record which now exists for diagnostic ultrasound

  6. Reliability of measuring abductor hallucis muscle parameters using two different diagnostic ultrasound machines

    Directory of Open Access Journals (Sweden)

    Cameron Alyse FM

    2009-11-01

    Full Text Available Abstract Background Diagnostic ultrasound provides a method of analysing soft tissue structures of the musculoskeletal system effectively and reliably. The aim of this study was to evaluate within and between session reliability of measuring muscle dorso-plantar thickness, medio-lateral length and cross-sectional area, of the abductor hallucis muscle using two different ultrasound machines, a higher end Philips HD11 Ultrasound machine and clinically orientated Chison 8300 Deluxe Digital Portable Ultrasound System. Methods The abductor hallucis muscle of both the left and right feet of thirty asymptomatic participants was imaged and then measured using both ultrasound machines. Interclass correlation coefficients (ICC with 95% confidence intervals (CI were used to calculate both within and between session intra-tester reliability. Standard error of the measurement (SEM calculations were undertaken to assess difference between the actual measured score across trials and the smallest real difference (SRD was calculated from the SEM to indicate the degree of change that would exceed the expected trial to trial variability. Results The ICCs, SEM and SRD for dorso-plantar thickness and medial-lateral length were shown to have excellent to high within and between-session reliability for both ultrasound machines. The between-session reliability indices for cross-sectional area were acceptable for both ultrasound machines. Conclusion The results of the current study suggest that regardless of the type ultrasound machine, intra-tester reliability for the measurement the abductor hallucis muscle parameters is very high.

  7. Evaluation of Chest Ultrasound Integrated Teaching of Respiratory System Physiology to Medical Students

    Science.gov (United States)

    Paganini, Matteo; Bondì, Michela; Rubini, Alessandro

    2017-01-01

    Ultrasound imaging is a widely used diagnostic technique, whose integration in medical education is constantly growing. The aim of this study was to evaluate chest ultrasound usefulness in teaching respiratory system physiology, students' perception of chest ultrasound integration into a traditional lecture in human physiology, and short-term…

  8. Improvement of diagnostic efficiency in distinguishing the benign and malignant thyroid nodules via conventional ultrasound combined with ultrasound contrast and elastography.

    Science.gov (United States)

    Liu, Mei-Juan; Men, Yan-Ming; Zhang, Yong-Lin; Zhang, Yu-Xi; Liu, Hao

    2017-07-01

    We aimed to evaluate the diagnostic values of conventional ultrasound (US), ultrasound contrast (UC) and ultrasound elastography (UE) in distinguishing the benign and malignant thyroid nodules. A total of 100 patients with thyroid nodules receiving operative treatment were selected; they underwent the conventional US, UE and UC examinations before operation, respectively. The nodules received pathological examination after operation to distinguish benign from malignant lesions. The sensitivity, specificity and diagnostic accordance rate of each diagnostic method was evaluated by receiver operating characteristic (ROC) curve, and the area under the curve (AUC) of ROC was calculated. The manifestations of malignant thyroid nodules in conventional US examination were mostly the hypoecho, heterogeneous echo, irregular shape, unclear boundary, aspect ratio benign and malignant nodules in 2, 3 and 4 points were statistically significant (Pbenign and malignant thyroid nodules.

  9. A survey of diagnostic ultrasound within the physiotherapy profession for the design of future training tools

    International Nuclear Information System (INIS)

    McKiernan, Sharmaine; Chiarelli, Pauline; Warren-Forward, Helen

    2011-01-01

    The expansion of diagnostic ultrasound outside of the traditional radiology profession into the physiotherapy profession is occurring. The purpose of this study was to determine if physiotherapists are purchasing diagnostic ultrasound machines, receiving training in the modality and what imaging procedures they are performing. For the design of future training tools, also investigated were the methods of training that physiotherapists might find most beneficial and what content they deem necessary to be covered during such training for the use of diagnostic ultrasound for their profession. An e-mail invitation was sent to physiotherapists throughout Australian who were registered on two databases, asking them to complete a web based survey. The survey was comprised of 18 questions including open and closed items. The data was then categorised into themes in accordance with the purpose of the study. Of the respondents, 39% did not own a diagnostic ultrasound machine, 33% had access to a machine that was owned by their employer and 18% actually owned a machine themselves. Training in diagnostic ultrasound had been received by 61% of the respondents however for 67% of those who had been trained, this training had only lasted for several hours, not days or weeks. For future training in ultrasound the majority of respondents would prefer either a workshop or DVD to cover imaging anatomy, the use of machine controls and scanning the pelvic floor, abdominal muscles and shoulder. From this survey it can be concluded that physiotherapists have an interest in or are using diagnostic ultrasound in their practice. While some form of training is being provided, further training is considered necessary and wanted by the physiotherapists so training tools need to be developed.

  10. A survey of diagnostic ultrasound within the physiotherapy profession for the design of future training tools

    Energy Technology Data Exchange (ETDEWEB)

    McKiernan, Sharmaine, E-mail: sharmaine.mckiernan@newcastle.edu.a [School of Health Sciences, University of Newcastle, Callaghan, NSW (Australia); Chiarelli, Pauline; Warren-Forward, Helen [School of Health Sciences, University of Newcastle, Callaghan, NSW (Australia)

    2011-05-15

    The expansion of diagnostic ultrasound outside of the traditional radiology profession into the physiotherapy profession is occurring. The purpose of this study was to determine if physiotherapists are purchasing diagnostic ultrasound machines, receiving training in the modality and what imaging procedures they are performing. For the design of future training tools, also investigated were the methods of training that physiotherapists might find most beneficial and what content they deem necessary to be covered during such training for the use of diagnostic ultrasound for their profession. An e-mail invitation was sent to physiotherapists throughout Australian who were registered on two databases, asking them to complete a web based survey. The survey was comprised of 18 questions including open and closed items. The data was then categorised into themes in accordance with the purpose of the study. Of the respondents, 39% did not own a diagnostic ultrasound machine, 33% had access to a machine that was owned by their employer and 18% actually owned a machine themselves. Training in diagnostic ultrasound had been received by 61% of the respondents however for 67% of those who had been trained, this training had only lasted for several hours, not days or weeks. For future training in ultrasound the majority of respondents would prefer either a workshop or DVD to cover imaging anatomy, the use of machine controls and scanning the pelvic floor, abdominal muscles and shoulder. From this survey it can be concluded that physiotherapists have an interest in or are using diagnostic ultrasound in their practice. While some form of training is being provided, further training is considered necessary and wanted by the physiotherapists so training tools need to be developed.

  11. Professional issues in the use of diagnostic ultrasound biofeedback in physiotherapy of the female pelvic floor

    International Nuclear Information System (INIS)

    McKiernan, Sharmaine; Chiarelli, Pauline; Warren-Forward, Helen

    2013-01-01

    The usage of diagnostic ultrasound equipment has expanded into physiotherapy. The aim of this paper is to deliver to both the ultrasound and physiotherapy professions an understanding of the use of diagnostic ultrasound for biofeedback in physiotherapy of the female pelvic floor and the issues related to competent and safe practice, including accessing suitable training. This has been evaluated using a qualitative research paradigm with data gathered via focus groups of Australian physiotherapists. The target group were pelvic floor physiotherapists as this is one of the main uses of diagnostic ultrasound within physiotherapy and the main area physiotherapists would like to be trained in. Two focus groups were run with a total of sixteen physiotherapists. Focus group participants reported their training in diagnostic ultrasound to be largely self directed. They also reported they were learning on their patients. Despite very limited training, participants demonstrated some familiarity with images and equipment settings. Participants felt the modality had a role within physiotherapy as an adjunct to their current practices. The main need raised by participants during the focus groups was related to patient expectations and the fact that the physiotherapist may miss evidence of pathology

  12. Diagnostic performance and useful findings of ultrasound re-evaluation for patients with equivocal CT features of acute appendicitis.

    Science.gov (United States)

    Kim, Mi Sung; Kwon, Heon-Ju; Kang, Kyung A; Do, In-Gu; Park, Hee-Jin; Kim, Eun Young; Hong, Hyun Pyo; Choi, Yoon Jung; Kim, Young Hwan

    2018-02-01

    To evaluate the diagnostic performance of ultrasound and to determine which ultrasound findings are useful to differentiate appendicitis from non-appendicitis in patients who underwent ultrasound re-evaluation owing to equivocal CT features of acute appendicitis. 62 patients who underwent CT examinations for suspected appendicitis followed by ultrasound re-evaluation owing to equivocal CT findings were included. Equivocal CT findings were considered based on the presence of only one or two findings among the CT criteria, and ultrasound re-evaluation was done based on a predefined structured report form. The diagnostic performance of ultrasound and independent variables to discriminate appendicitis from non-appendicitis were assessed. There were 27 patients in the appendicitis group. The overall diagnostic performance of ultrasound re-evaluation was sensitivity of 96.3%, specificity of 91.2% and accuracy of 91.9%. In terms of the performance of individual ultrasound findings, probe-induced tenderness showed the highest accuracy (86.7%) with sensitivity of 74% and specificity of 97%, followed by non-compressibility (accuracy 71.7%, sensitivity 85.2% and specificity 60.6%). The independent ultrasound findings for discriminating appendicitis were non-compressibility (p = 0.002) and increased flow on the appendiceal wall (p = 0.001). Ultrasound re-evaluation can be used to improve diagnostic accuracy in cases with equivocal CT features for diagnosing appendicitis. The presence of non-compressibility and increased vascular flow on the appendix wall are useful ultrasound findings to discriminate appendicitis from non-appendicitis. Advances in knowledge: Ultrasound re-evaluation is useful to discriminate appendicitis from non-appendicitis when CT features are inconclusive.

  13. Unilateral Opening of Rat Blood-Brain Barrier Assisted by Diagnostic Ultrasound Targeted Microbubbles Destruction.

    Science.gov (United States)

    Xu, Yali; Cui, Hai; Zhu, Qiong; Hua, Xing; Xia, Hongmei; Tan, Kaibin; Gao, Yunhua; Zhao, Jing; Liu, Zheng

    2016-01-01

    Objective. Blood-brain barrier (BBB) is a key obstacle that prevents the medication from blood to the brain. Microbubble-enhanced cavitation by focused ultrasound can open the BBB and proves to be valuable in the brain drug delivery. The study aimed to explore the feasibility, efficacy, and safety of unilateral opening of BBB using diagnostic ultrasound targeted microbubbles destruction in rats. Methods. A transtemporal bone irradiation of diagnostic ultrasound and intravenous injection of lipid-coated microbubbles were performed at unilateral hemisphere. Pathological changes were monitored. Evans Blue extravasation grades, extraction from brain tissue, and fluorescence optical density were quantified. Lanthanum nitrate was traced by transmission electron microscopy. Results. After diagnostic ultrasound mediated microbubbles destruction, Evans Blue extravasation and fluorescence integrated optical density were significantly higher in the irradiated hemisphere than the contralateral side (all p ultrasound-exposed hemisphere (4 ± 1, grade 2) while being invisible in the control side. Lanthanum nitrate tracers leaked through interendothelial cleft and spread to the nerve fiber existed in the irradiation side. Conclusions. Transtemporal bone irradiation under DUS mediated microbubble destruction provides us with a more accessible, safer, and higher selective BBB opening approach in rats, which is advantageous in brain targeted drugs delivery.

  14. Unilateral Opening of Rat Blood-Brain Barrier Assisted by Diagnostic Ultrasound Targeted Microbubbles Destruction

    Directory of Open Access Journals (Sweden)

    Yali Xu

    2016-01-01

    Full Text Available Objective. Blood-brain barrier (BBB is a key obstacle that prevents the medication from blood to the brain. Microbubble-enhanced cavitation by focused ultrasound can open the BBB and proves to be valuable in the brain drug delivery. The study aimed to explore the feasibility, efficacy, and safety of unilateral opening of BBB using diagnostic ultrasound targeted microbubbles destruction in rats. Methods. A transtemporal bone irradiation of diagnostic ultrasound and intravenous injection of lipid-coated microbubbles were performed at unilateral hemisphere. Pathological changes were monitored. Evans Blue extravasation grades, extraction from brain tissue, and fluorescence optical density were quantified. Lanthanum nitrate was traced by transmission electron microscopy. Results. After diagnostic ultrasound mediated microbubbles destruction, Evans Blue extravasation and fluorescence integrated optical density were significantly higher in the irradiated hemisphere than the contralateral side (all p<0.01. Erythrocytes extravasations were demonstrated in the ultrasound-exposed hemisphere (4±1, grade 2 while being invisible in the control side. Lanthanum nitrate tracers leaked through interendothelial cleft and spread to the nerve fiber existed in the irradiation side. Conclusions. Transtemporal bone irradiation under DUS mediated microbubble destruction provides us with a more accessible, safer, and higher selective BBB opening approach in rats, which is advantageous in brain targeted drugs delivery.

  15. MO-AB-210-02: Ultrasound Imaging and Therapy-Hands On Workshop

    International Nuclear Information System (INIS)

    Sammet, S.

    2015-01-01

    The goal of this ultrasound hands-on workshop is to demonstrate advancements in high intensity focused ultrasound (HIFU) and to demonstrate quality control (QC) testing in diagnostic ultrasound. HIFU is a therapeutic modality that uses ultrasound waves as carriers of energy. HIFU is used to focus a beam of ultrasound energy into a small volume at specific target locations within the body. The focused beam causes localized high temperatures and produces a well-defined regions of necrosis. This completely non-invasive technology has great potential for tumor ablation and targeted drug delivery. At the workshop, attendees will see configurations, applications, and hands-on demonstrations with on-site instructors at separate stations. The involvement of medical physicists in diagnostic ultrasound imaging service is increasing due to QC and accreditation requirements. At the workshop, an array of ultrasound testing phantoms and ultrasound scanners will be provided for attendees to learn diagnostic ultrasound QC in a hands-on environment with live demonstrations of the techniques. Target audience: Medical physicists and other medical professionals in diagnostic imaging and radiation oncology with interest in high-intensity focused ultrasound and in diagnostic ultrasound QC. Learning Objectives: Learn ultrasound physics and safety for HIFU applications through live demonstrations Get an overview of the state-of-the art in HIFU technologies and equipment Gain familiarity with common elements of a quality control program for diagnostic ultrasound imaging Identify QC tools available for testing diagnostic ultrasound systems and learn how to use these tools List of supporting vendors for HIFU and diagnostic ultrasound QC hands-on workshop: Philips Healthcare Alpinion Medical Systems Verasonics, Inc Zonare Medical Systems, Inc Computerized Imaging Reference Systems (CIRS), Inc. GAMMEX, Inc., Cablon Medical BV Steffen Sammet: NIH/NCI grant 5R25CA132822, NIH/NINDS grant 5R25NS

  16. MO-AB-210-01: Ultrasound Imaging and Therapy-Hands On Workshop

    International Nuclear Information System (INIS)

    Lu, Z.

    2015-01-01

    The goal of this ultrasound hands-on workshop is to demonstrate advancements in high intensity focused ultrasound (HIFU) and to demonstrate quality control (QC) testing in diagnostic ultrasound. HIFU is a therapeutic modality that uses ultrasound waves as carriers of energy. HIFU is used to focus a beam of ultrasound energy into a small volume at specific target locations within the body. The focused beam causes localized high temperatures and produces a well-defined regions of necrosis. This completely non-invasive technology has great potential for tumor ablation and targeted drug delivery. At the workshop, attendees will see configurations, applications, and hands-on demonstrations with on-site instructors at separate stations. The involvement of medical physicists in diagnostic ultrasound imaging service is increasing due to QC and accreditation requirements. At the workshop, an array of ultrasound testing phantoms and ultrasound scanners will be provided for attendees to learn diagnostic ultrasound QC in a hands-on environment with live demonstrations of the techniques. Target audience: Medical physicists and other medical professionals in diagnostic imaging and radiation oncology with interest in high-intensity focused ultrasound and in diagnostic ultrasound QC. Learning Objectives: Learn ultrasound physics and safety for HIFU applications through live demonstrations Get an overview of the state-of-the art in HIFU technologies and equipment Gain familiarity with common elements of a quality control program for diagnostic ultrasound imaging Identify QC tools available for testing diagnostic ultrasound systems and learn how to use these tools List of supporting vendors for HIFU and diagnostic ultrasound QC hands-on workshop: Philips Healthcare Alpinion Medical Systems Verasonics, Inc Zonare Medical Systems, Inc Computerized Imaging Reference Systems (CIRS), Inc. GAMMEX, Inc., Cablon Medical BV Steffen Sammet: NIH/NCI grant 5R25CA132822, NIH/NINDS grant 5R25NS

  17. MO-AB-210-02: Ultrasound Imaging and Therapy-Hands On Workshop

    Energy Technology Data Exchange (ETDEWEB)

    Sammet, S. [University of Chicago Medical Center (United States)

    2015-06-15

    The goal of this ultrasound hands-on workshop is to demonstrate advancements in high intensity focused ultrasound (HIFU) and to demonstrate quality control (QC) testing in diagnostic ultrasound. HIFU is a therapeutic modality that uses ultrasound waves as carriers of energy. HIFU is used to focus a beam of ultrasound energy into a small volume at specific target locations within the body. The focused beam causes localized high temperatures and produces a well-defined regions of necrosis. This completely non-invasive technology has great potential for tumor ablation and targeted drug delivery. At the workshop, attendees will see configurations, applications, and hands-on demonstrations with on-site instructors at separate stations. The involvement of medical physicists in diagnostic ultrasound imaging service is increasing due to QC and accreditation requirements. At the workshop, an array of ultrasound testing phantoms and ultrasound scanners will be provided for attendees to learn diagnostic ultrasound QC in a hands-on environment with live demonstrations of the techniques. Target audience: Medical physicists and other medical professionals in diagnostic imaging and radiation oncology with interest in high-intensity focused ultrasound and in diagnostic ultrasound QC. Learning Objectives: Learn ultrasound physics and safety for HIFU applications through live demonstrations Get an overview of the state-of-the art in HIFU technologies and equipment Gain familiarity with common elements of a quality control program for diagnostic ultrasound imaging Identify QC tools available for testing diagnostic ultrasound systems and learn how to use these tools List of supporting vendors for HIFU and diagnostic ultrasound QC hands-on workshop: Philips Healthcare Alpinion Medical Systems Verasonics, Inc Zonare Medical Systems, Inc Computerized Imaging Reference Systems (CIRS), Inc. GAMMEX, Inc., Cablon Medical BV Steffen Sammet: NIH/NCI grant 5R25CA132822, NIH/NINDS grant 5R25NS

  18. MO-AB-210-01: Ultrasound Imaging and Therapy-Hands On Workshop

    Energy Technology Data Exchange (ETDEWEB)

    Lu, Z. [University of Chicago (United States)

    2015-06-15

    The goal of this ultrasound hands-on workshop is to demonstrate advancements in high intensity focused ultrasound (HIFU) and to demonstrate quality control (QC) testing in diagnostic ultrasound. HIFU is a therapeutic modality that uses ultrasound waves as carriers of energy. HIFU is used to focus a beam of ultrasound energy into a small volume at specific target locations within the body. The focused beam causes localized high temperatures and produces a well-defined regions of necrosis. This completely non-invasive technology has great potential for tumor ablation and targeted drug delivery. At the workshop, attendees will see configurations, applications, and hands-on demonstrations with on-site instructors at separate stations. The involvement of medical physicists in diagnostic ultrasound imaging service is increasing due to QC and accreditation requirements. At the workshop, an array of ultrasound testing phantoms and ultrasound scanners will be provided for attendees to learn diagnostic ultrasound QC in a hands-on environment with live demonstrations of the techniques. Target audience: Medical physicists and other medical professionals in diagnostic imaging and radiation oncology with interest in high-intensity focused ultrasound and in diagnostic ultrasound QC. Learning Objectives: Learn ultrasound physics and safety for HIFU applications through live demonstrations Get an overview of the state-of-the art in HIFU technologies and equipment Gain familiarity with common elements of a quality control program for diagnostic ultrasound imaging Identify QC tools available for testing diagnostic ultrasound systems and learn how to use these tools List of supporting vendors for HIFU and diagnostic ultrasound QC hands-on workshop: Philips Healthcare Alpinion Medical Systems Verasonics, Inc Zonare Medical Systems, Inc Computerized Imaging Reference Systems (CIRS), Inc. GAMMEX, Inc., Cablon Medical BV Steffen Sammet: NIH/NCI grant 5R25CA132822, NIH/NINDS grant 5R25NS

  19. WE-AB-206-02: ACR Ultrasound Accreditation: Requirements and Pitfalls

    International Nuclear Information System (INIS)

    Walter, J.

    2016-01-01

    The involvement of medical physicists in diagnostic ultrasound imaging service is increasing due to QC and accreditation requirements. The goal of this ultrasound hands-on workshop is to demonstrate quality control (QC) testing in diagnostic ultrasound and to provide updates in ACR ultrasound accreditation requirements. The first half of this workshop will include two presentations reviewing diagnostic ultrasound QA/QC and ACR ultrasound accreditation requirements. The second half of the workshop will include live demonstrations of basic QC tests. An array of ultrasound testing phantoms and ultrasound scanners will be available for attendees to learn diagnostic ultrasound QC in a hands-on environment with live demonstrations and on-site instructors. The targeted attendees are medical physicists in diagnostic imaging. Learning Objectives: Gain familiarity with common elements of a QA/QC program for diagnostic ultrasound imaging dentify QC tools available for testing diagnostic ultrasound systems and learn how to use these tools Learn ACR ultrasound accreditation requirements Jennifer Walter is an employee of American College of Radiology on Ultrasound Accreditation.

  20. MO-AB-210-03: Workshop [Advancements in high intensity focused ultrasound

    Energy Technology Data Exchange (ETDEWEB)

    Lu, Z. [University of Chicago (United States)

    2015-06-15

    The goal of this ultrasound hands-on workshop is to demonstrate advancements in high intensity focused ultrasound (HIFU) and to demonstrate quality control (QC) testing in diagnostic ultrasound. HIFU is a therapeutic modality that uses ultrasound waves as carriers of energy. HIFU is used to focus a beam of ultrasound energy into a small volume at specific target locations within the body. The focused beam causes localized high temperatures and produces a well-defined regions of necrosis. This completely non-invasive technology has great potential for tumor ablation and targeted drug delivery. At the workshop, attendees will see configurations, applications, and hands-on demonstrations with on-site instructors at separate stations. The involvement of medical physicists in diagnostic ultrasound imaging service is increasing due to QC and accreditation requirements. At the workshop, an array of ultrasound testing phantoms and ultrasound scanners will be provided for attendees to learn diagnostic ultrasound QC in a hands-on environment with live demonstrations of the techniques. Target audience: Medical physicists and other medical professionals in diagnostic imaging and radiation oncology with interest in high-intensity focused ultrasound and in diagnostic ultrasound QC. Learning Objectives: Learn ultrasound physics and safety for HIFU applications through live demonstrations Get an overview of the state-of-the art in HIFU technologies and equipment Gain familiarity with common elements of a quality control program for diagnostic ultrasound imaging Identify QC tools available for testing diagnostic ultrasound systems and learn how to use these tools List of supporting vendors for HIFU and diagnostic ultrasound QC hands-on workshop: Philips Healthcare Alpinion Medical Systems Verasonics, Inc Zonare Medical Systems, Inc Computerized Imaging Reference Systems (CIRS), Inc. GAMMEX, Inc., Cablon Medical BV Steffen Sammet: NIH/NCI grant 5R25CA132822, NIH/NINDS grant 5R25NS

  1. Clinical Evaluation of Iliopsoas Strain with Findings from Diagnostic Musculoskeletal Ultrasound in Agility Performance Canines – 73 Cases

    Directory of Open Access Journals (Sweden)

    Robert Cullen

    2017-06-01

    Full Text Available Objective: Iliopsoas injury and strain is a commonly diagnosed disease process, especially amongst working and sporting canines. There has been very little published literature regarding iliopsoas injuries and there is no information regarding the ultrasound evaluation of abnormal iliopsoas muscles. This manuscript is intended to describe the ultrasound findings in 73 canine agility athletes who had physical examination findings consistent with iliopsoas discomfort. The population was chosen given the high incidence of these animals for the development of iliopsoas injury; likely due to repetitive stress.Methods: Medical records of 73 agility performance canines that underwent musculoskeletal ultrasound evaluation of bilateral iliopsoas muscle groups were retrospectively reviewed. Data included signalment, previous radiographic findings, and ultrasound findings. A 3-tier grading scheme for acute strains was used while the practitioner also evaluated for evidence of chronic injury and bursitis.Results: The majority of pathologies were localised to the tendon of insertion, with the majority being low grade I-II strains (80.8%. Tendon fibre disruption (71.2% and indistinct hypoechoic lesions (91.8% were the most common of acute changes noted. Hyperechoic chronic changes were noted in 84.9 percent of cases. Acute and chronic changes were commonly seen together (62.8%.Conclusion: Diagnostic musculoskeletal ultrasound was used to identify lesions of the iliopsoas tendon consistent with acute and chronic injury, as well as identifying the region of pathology. The majority of agility performance dogs had low grade acute strains based on the tiered system, with mixed acute and chronic lesions being noted frequently.Application: Diagnostic musculoskeletal ultrasound provides a non-invasive diagnostic modality for patients suspected of having an iliopsoas strain.

  2. Breast Ultrasound Examination with Video Monitor System: A Satisfaction Survey among Patients

    International Nuclear Information System (INIS)

    Ryu, Jung Kyu; Kim, Hyun Cheol; Yang, Dal Mo

    2010-01-01

    The purpose of this study is to assess the patients satisfaction with a newly established video-monitor system and the associated basic items for performing breast ultrasound exams by conducting a survey among the patients. 349 patients were invited to take the survey and they had undergone breast ultrasound examination once during the 3 months after the monitor system has been introduced. The questionnaire was composed of 8 questions, 4 of which were about the basic items such as age, gender and the reason of their taking the breast ultrasound exam, their preference for the gender of the examiner and the desired length of time for the examination. The other 4 question were about their satisfaction with the video monitor. The patients were divided into two groups according to the purposes of taking the exams, which were screening or diagnostic purposes. The results were compared between these 2 groups. The satisfaction with the video monitor system was assessed by using a scoring system that ranged from 1 to 5. For the total patients, the screening group was composed of 124 patients and the diagnostic group was composed of 225. The reasons why the patients wanted to take the examinations in the diagnostic group varied. The questionnaire about the preference of the gender of the examiner showed that 81.5% in the screening group and 79.1% in the diagnostic group preferred a woman doctor. The required, suitable time for the breast ultrasound examination was 5 to 10 minutes or 10 to 15 minutes for about 70% of the patients. The mean satisfaction score for the video monitor system was as high as 3.95 point. The portion of patients in each group who answered over 3 points for their satisfaction with the monitor system was 88.7% and 94.2%, respectively. Our study showed that patients preferred 5-15 minutes for the length of the examination time and a female examiner. We also confirmed high patient satisfaction with the video monitor system

  3. Breast Ultrasound Examination with Video Monitor System: A Satisfaction Survey among Patients

    Energy Technology Data Exchange (ETDEWEB)

    Ryu, Jung Kyu; Kim, Hyun Cheol; Yang, Dal Mo [East-West Neo Medical Center, Kyung-Hee University, Seoul (Korea, Republic of)

    2010-03-15

    The purpose of this study is to assess the patients satisfaction with a newly established video-monitor system and the associated basic items for performing breast ultrasound exams by conducting a survey among the patients. 349 patients were invited to take the survey and they had undergone breast ultrasound examination once during the 3 months after the monitor system has been introduced. The questionnaire was composed of 8 questions, 4 of which were about the basic items such as age, gender and the reason of their taking the breast ultrasound exam, their preference for the gender of the examiner and the desired length of time for the examination. The other 4 question were about their satisfaction with the video monitor. The patients were divided into two groups according to the purposes of taking the exams, which were screening or diagnostic purposes. The results were compared between these 2 groups. The satisfaction with the video monitor system was assessed by using a scoring system that ranged from 1 to 5. For the total patients, the screening group was composed of 124 patients and the diagnostic group was composed of 225. The reasons why the patients wanted to take the examinations in the diagnostic group varied. The questionnaire about the preference of the gender of the examiner showed that 81.5% in the screening group and 79.1% in the diagnostic group preferred a woman doctor. The required, suitable time for the breast ultrasound examination was 5 to 10 minutes or 10 to 15 minutes for about 70% of the patients. The mean satisfaction score for the video monitor system was as high as 3.95 point. The portion of patients in each group who answered over 3 points for their satisfaction with the monitor system was 88.7% and 94.2%, respectively. Our study showed that patients preferred 5-15 minutes for the length of the examination time and a female examiner. We also confirmed high patient satisfaction with the video monitor system

  4. Diagnostic errors in musculoskeletal ultrasound imaging and how to avoid them

    Directory of Open Access Journals (Sweden)

    Małgorzata Serafin-Król

    2017-09-01

    Full Text Available The article reviews the major challenges related to the principles of the correct technique of musculoskeletal ultrasound (MSK US. All the crucial aspects of correct MSK soft tissue diagnosis have been discussed, including equipment settings, use of recent image software innovations and ultrasound standoff pads, and correct transducer positioning. The importance of the fundamental principles of MSK US, facilitating good quality image and limiting the occurrence of artifacts, has been highlighted. The most common artifacts of the musculoskeletal system have been described, including those that diagnostically helpful, such as the presence of echo enhancement deep to a fluidfilled structure, or an acoustic shadow behind a calcification. The presence of acoustic shadow in the context of lesions of a different type has also been discussed. The common anisotropy-related artifacts, frequently leading to diagnosis of a pathological condition where none is present, have been elaborated on. The frequently encountered mirror reflection artifact has been described. Special attention has been paid to the means of either eliminating, or taking advantage of artifacts for the correct diagnosis of musculoskeletal lesions. The possibilities and technique of correct differentiation of hypoechoic or anechoic foci, commonly found in the pathological conditions of the musculoskeletal system, have been analysed. Non-typical ultrasound findings leading to misdiagnosis of given pathological conditions have been discussed.

  5. Non-invasive estimation of temperature using diagnostic ultrasound during HIFU therapy

    Science.gov (United States)

    Georg, O.; Wilkens, V.

    2017-03-01

    The use of HIFU for thermal ablation of human tissues requires safe real-time monitoring of the lesion formation during the treatment to avoid damage of the surrounding healthy tissues and to control temperature rise. Besides MR imaging, several methods have been proposed for temperature imaging using diagnostic ultrasound, and echoshift estimation (using speckle tracking) is the most promising and commonly used technique. It is based on the thermal dependence of the ultrasound echo that accounts for two different physical phenomena: local change in speed of sound and thermal expansion of the propagating medium due to changes in temperature. In our experiments we have used two separate transducers: HIFU exposure was performed using a 1.06 MHz single element focusing transducer of 64 mm aperture and 63.2 mm focal length; the ultrasound diagnostic probe of 11 MHz operated in B-mode for image guidance. The temperature measurements were performed in an agar-based tissue-mimicking phantom. To verify the obtained results, numerical modeling of the acoustic and temperature fields was carried out using KZK and Pennes Bioheat equations, as well as measurements with thermocouples were performed.

  6. The diagnostic validity of musculoskeletal ultrasound in lateral epicondylalgia: a systematic review

    International Nuclear Information System (INIS)

    Dones, Valentin C III; Grimmer, Karen; Thoirs, Kerry; Suarez, Consuelo G; Luker, Julie

    2014-01-01

    Ultrasound is considered a reliable, widely available, non-invasive and inexpensive imaging technique for assessing soft tissue involvement in Lateral epicondylalgia. Despite the number of diagnostic studies for Lateral Epicondylalgia, there is no consensus in the current literature on the best abnormal ultrasound findings that confirm lateral epicondylalgia. Eligible studies identified by searching electronic databases, scanning reference lists of articles and chapters on ultrasound in reference books, and consultation of experts in sonography. Three reviewers (VCDIII, KP, KW) independently searched the databases using the agreed search strategy, and independently conducted all stages of article selection. Two reviewers (VCDIII, KP) then screened titles and abstracts to remove obvious irrelevance. Potentially relevant full text publications which met the inclusion criteria were reviewed by the primary investigator (VCDIII) and another reviewer (CGS). Among the 15 included diagnostic studies in this review, seven were Level II diagnostic accuracy studies for chronic lateral epicondylalgia based on the National Health and Medical Research Council Hierarchy of Evidence. Based from the pooled sensitivity of abnormal ultrasound findings with homogenous results (p > 0.05), the hypoechogenicity of the common extensor origin has the best combination of diagnostic sensitivity and specificity. It is moderately sensitive [Sensitivity: 0.64 (0.56-0.72)] and highly specific [Specificity: 0.82 (0.72-0.90)] in determining elbows with lateral epicondylalgia. Additionally, bone changes on the lateral epicondyle [Sensitivity: 0.56 (0.50-0.62)] were moderately sensitive to chronic LE. Conversely, neovascularity [Specificity: 1.00 (0.97-1.00)], calcifications [Specificity: 0.97 (0.94-0.99)] and cortical irregularities [Specificity: 0.96 (0.88-0.99)] have strong specificity for chronic lateral epicondylalgia. There is insufficient evidence supporting the use of Power Doppler

  7. Principles of Billing for Diagnostic Ultrasound in the Office and Operating Room.

    Science.gov (United States)

    Grasu, Beatrice L; Wolock, Bruce S; Sedgley, Matthew D; Murphy, Michael S

    2018-05-08

    Ultrasound is becoming more prevalent as physicians gain comfort in its diagnostic and therapeutic uses. It allows for both static and dynamic evaluation of conditions and assists in therapeutic injections of joints and tendons. Proper technique is necessary for successful use of this modality. Appropriate coding for physician reimbursement is required. We discuss common wrist and hand pathology for which ultrasound may be useful as an adjunct to diagnosis and treatment and provide an overview of technique and reimbursement codes when using ultrasound in a variety of situations. Copyright © 2018 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  8. What is the role of clinical tests and ultrasound in acetabular labral tear diagnostics?

    DEFF Research Database (Denmark)

    Troelsen, Anders; Mechlenburg, Inger; Gelineck, John

    2009-01-01

    BACKGROUND AND PURPOSE: An acetabular labral tear is a diagnostic challenge. Various clinical tests have been described, but little is known about their diagnostic sensitivity and specificity. We investigated the diagnostic validity of clinical tests and ultrasound as compared with MR arthrography...... no or only slight signs of osteoarthritis (Tönnis grade 0-1). RESULTS: MR arthrography identified labral tears in 17 of the 18 hips. Ultrasound had a sensitivity of 94%, a positive predictive value of 94%, and was false negative in only 1 case compared to MR arthrography. The impingement test had the best...... diagnostic ability of the clinical tests, with a sensitivity of 59% and a specificity of 100%. The positive predictive value was 100% while the negative predictive value was 13%. INTERPRETATION: The impingement test is helpful in identifying acetabular labral tears. If this test is negative and if a labral...

  9. Low-cost Volumetric Ultrasound by Augmentation of 2D Systems: Design and Prototype.

    Science.gov (United States)

    Herickhoff, Carl D; Morgan, Matthew R; Broder, Joshua S; Dahl, Jeremy J

    2018-01-01

    Conventional two-dimensional (2D) ultrasound imaging is a powerful diagnostic tool in the hands of an experienced user, yet 2D ultrasound remains clinically underutilized and inherently incomplete, with output being very operator dependent. Volumetric ultrasound systems can more fully capture a three-dimensional (3D) region of interest, but current 3D systems require specialized transducers, are prohibitively expensive for many clinical departments, and do not register image orientation with respect to the patient; these systems are designed to provide improved workflow rather than operator independence. This work investigates whether it is possible to add volumetric 3D imaging capability to existing 2D ultrasound systems at minimal cost, providing a practical means of reducing operator dependence in ultrasound. In this paper, we present a low-cost method to make 2D ultrasound systems capable of quality volumetric image acquisition: we present the general system design and image acquisition method, including the use of a probe-mounted orientation sensor, a simple probe fixture prototype, and an offline volume reconstruction technique. We demonstrate initial results of the method, implemented using a Verasonics Vantage research scanner.

  10. Blood-brain barrier disruption induced by diagnostic ultrasound combined with microbubbles in mice.

    Science.gov (United States)

    Zhao, Bingxia; Chen, Yihan; Liu, Jinfeng; Zhang, Li; Wang, Jing; Yang, Yali; Lv, Qing; Xie, Mingxing

    2018-01-12

    To investigate the effects of the microbubble (MB) dose, mechanism index (MI) and sonication duration on blood-brain barrier (BBB) disruption induced by diagnostic ultrasound combined with MBs as well as to investigate the potential molecular mechanism. The extent of BBB disruption increased with MB dose, MI and sonication duration. A relatively larger extent of BBB disruption associated with minimal tissue damage was achieved by an appropriate MB dose and ultrasound exposure parameters with diagnostic ultrasound. Decreased expression of ZO-1, occludin and claudin-5 were correlated with disruption of the BBB, as confirmed by paracellular passage of the tracer lanthanum nitrate into the brain parenchyma after BBB disruption. These findings indicated that this technique is a promising tool for promoting brain delivery of diagnostic and therapeutic agents in the diagnosis and treatment of brain diseases. The extent of BBB disruption was qualitatively assessed by Evans blue (EB) staining and quantitatively analyzed by an EB extravasation measurement. A histological examination was performed to evaluate tissue damage. Expression of tight junction (TJ) related proteins ZO-1, occludin and claudin-5 was determined by western blotting analysis and immunohistofluorescence. Transmission electron microscopy was performed to observe ultrastructure changes of TJs after BBB disruption.

  11. Therapeutic ultrasound

    International Nuclear Information System (INIS)

    Crum, Lawrence A

    2004-01-01

    The use of ultrasound in medicine is now quite commonplace, especially with the recent introduction of small, portable and relatively inexpensive, hand-held diagnostic imaging devices. Moreover, ultrasound has expanded beyond the imaging realm, with methods and applications extending to novel therapeutic and surgical uses. These applications broadly include: tissue ablation, acoustocautery, lipoplasty, site-specific and ultrasound mediated drug activity, extracorporeal lithotripsy, and the enhancement of natural physiological functions such as wound healing and tissue regeneration. A particularly attractive aspect of this technology is that diagnostic and therapeutic systems can be combined to produce totally non-invasive, imageguided therapy. This general lecture will review a number of these exciting new applications of ultrasound and address some of the basic scientific questions and future challenges in developing these methods and technologies for general use in our society. We shall particularly emphasize the use of High Intensity Focused Ultrasound (HIFU) in the treatment of benign and malignant tumors as well as the introduction of acoustic hemostasis, especially in organs which are difficult to treat using conventional medical and surgical techniques. (amum lecture)

  12. Transbiliary intravascular ultrasound-guided diagnostic biopsy of an inaccessible pancreatic head mass

    Directory of Open Access Journals (Sweden)

    Jeffrey Forris Beecham Chick, MD, MPH, DABR

    2017-06-01

    Full Text Available Percutaneous image-guided biopsies of pancreatic malignancies may prove challenging and nondiagnostic due to a variety of anatomic considerations. For patients with complex post-surgical anatomy, such as a Roux-en-Y gastric bypass, diagnosis via endoscopic ultrasound with fine-needle aspiration may not be possible because of an inability to reach the proximal duodenum. This report describes the first diagnostic case of transbiliary intravascular ultrasound-guided biopsy of a pancreatic head mass in a patient with prior Roux-en-Y gastric bypass for which a diagnosis could not be achieved via percutaneous and endoscopic approaches. Transbiliary intravascular ultrasound-guided biopsy resulted in a diagnosis of pancreatic adenocarcinoma, allowing the initiation of chemotherapy.

  13. Anterolateral ankle impingement: findings and diagnostic accuracy with ultrasound imaging

    International Nuclear Information System (INIS)

    McCarthy, C.L.; Wilson, D.J.; Coltman, T.P.

    2008-01-01

    The objective was to evaluate the findings and diagnostic accuracy of ultrasound in antero-lateral ankle impingement (ALI) with clinical and arthroscopic correlation. Seventeen elite footballers with chronic ankle pain were referred for ultrasound with a clinical diagnosis of ALI (n = 8) or a control condition (n = 9; lateral mechanical instability, osteochondral defect, intra-articular bodies and osteoarthritis). Ultrasound examination included the antero-lateral gutter for abnormal synovial tissue (synovitic lesion), lateral ligament integrity, tibiotalar joint and osseous spurs of the distal tibia and talus. Ultrasound findings were correlated with subsequent arthroscopic appearance. Ultrasound examination detected a synovitic mass in the antero-lateral gutter in all 8 footballers with clinical ALI (100%) and in 2 patients with a control diagnosis (22%). Arthroscopic correlation of antero-lateral synovitis and fibrosis was present in all 10 cases (100%). The synovitic lesion was seen at ultrasound as a nodular soft tissue mass of mixed echogenicity within the antero-lateral gutter, which extruded anteriorly with manual compression of the distal fibula against the tibia. Increased blood supply was detected using power Doppler imaging in only 1 patient. The synovitic lesion measured >10 mm in its maximum dimension in 7 footballers with clinical ALI and <10 mm in the control group. Additional ultrasound findings in patients with abnormal antero-lateral synovial tissue included an anterior talofibular ligament injury in all patients (n = 10), a tibiotalar joint effusion (n = 6) and osseous spurs (n = 4). Antero-lateral synovitic tissue was accurately identified at ultrasound in the absence of an effusion (n = 4). No synovitic lesion was detected at ultrasound or arthroscopy in the remaining 7 patients with a control diagnosis. Ultrasound is accurate in detecting synovitic lesions within the antero-lateral gutter, demonstrating associated ligamentous injuries and in

  14. Comparison of Diagnostic Performance of Semi-Quantitative Knee Ultrasound and Knee Radiography with MRI: Oulu Knee Osteoarthritis Study

    Science.gov (United States)

    Podlipská, Jana; Guermazi, Ali; Lehenkari, Petri; Niinimäki, Jaakko; Roemer, Frank W.; Arokoski, Jari P.; Kaukinen, Päivi; Liukkonen, Esa; Lammentausta, Eveliina; Nieminen, Miika T.; Tervonen, Osmo; Koski, Juhani M.; Saarakkala, Simo

    2016-01-01

    Osteoarthritis (OA) is a common degenerative musculoskeletal disease highly prevalent in aging societies worldwide. Traditionally, knee OA is diagnosed using conventional radiography. However, structural changes of articular cartilage or menisci cannot be directly evaluated using this method. On the other hand, ultrasound is a promising tool able to provide direct information on soft tissue degeneration. The aim of our study was to systematically determine the site-specific diagnostic performance of semi-quantitative ultrasound grading of knee femoral articular cartilage, osteophytes and meniscal extrusion, and of radiographic assessment of joint space narrowing and osteophytes, using MRI as a reference standard. Eighty asymptomatic and 79 symptomatic subjects with mean age of 57.7 years were included in the study. Ultrasound performed best in the assessment of femoral medial and lateral osteophytes, and medial meniscal extrusion. In comparison to radiography, ultrasound performed better or at least equally well in identification of tibio-femoral osteophytes, medial meniscal extrusion and medial femoral cartilage morphological degeneration. Ultrasound provides relevant additional diagnostic information on tissue-specific morphological changes not depicted by conventional radiography. Consequently, the use of ultrasound as a complementary imaging tool along with radiography may enable more accurate and cost-effective diagnostics of knee osteoarthritis at the primary healthcare level. PMID:26926836

  15. Endoscopic and ultrasound diagnostics as contemporary method in diagnostics of dog stomach diseases

    Directory of Open Access Journals (Sweden)

    Krstić Vanja

    2005-01-01

    Full Text Available The visualization of pathological processes in the dog stomach determines a correct diagnosis or differential diagnosis, which presents the basic prerequisite for rational therapy. In addition to the conventional type of clinical examination which covers the taking of anamnestic data, observation of the patient and laboratory tests, there are also certain computerized diagnostic methods (magnetic resonance and scanner which are the most precise and most reliable in the verification of stomach diseases. However, the listed approaches are either insufficiently relevant in making the diagnosis or are too expensive and demanding for the everyday clinical practice. These are the reasons why veterinary medicine today increasingly resorts to the use of other forms of imaging diagnostics, and, as its representatives, the video endoscopic, ultrasound and X-ray examination of the digestive tract.

  16. CT and Ultrasound Guided Stereotactic High Intensity Focused Ultrasound (HIFU)

    Science.gov (United States)

    Wood, Bradford J.; Yanof, J.; Frenkel, V.; Viswanathan, A.; Dromi, S.; Oh, K.; Kruecker, J.; Bauer, C.; Seip, R.; Kam, A.; Li, K. C. P.

    2006-05-01

    To demonstrate the feasibility of CT and B-mode Ultrasound (US) targeted HIFU, a prototype coaxial focused ultrasound transducer was registered and integrated to a CT scanner. CT and diagnostic ultrasound were used for HIFU targeting and monitoring, with the goals of both thermal ablation and non-thermal enhanced drug delivery. A 1 megahertz coaxial ultrasound transducer was custom fabricated and attached to a passive position-sensing arm and an active six degree-of-freedom robotic arm via a CT stereotactic frame. The outer therapeutic transducer with a 10 cm fixed focal zone was coaxially mounted to an inner diagnostic US transducer (2-4 megahertz, Philips Medical Systems). This coaxial US transducer was connected to a modified commercial focused ultrasound generator (Focus Surgery, Indianapolis, IN) with a maximum total acoustic power of 100 watts. This pre-clinical paradigm was tested for ability to heat tissue in phantoms with monitoring and navigation from CT and live US. The feasibility of navigation via image fusion of CT with other modalities such as PET and MRI was demonstrated. Heated water phantoms were tested for correlation between CT numbers and temperature (for ablation monitoring). The prototype transducer and integrated CT/US imaging system enabled simultaneous multimodality imaging and therapy. Pre-clinical phantom models validated the treatment paradigm and demonstrated integrated multimodality guidance and treatment monitoring. Temperature changes during phantom cooling corresponded to CT number changes. Contrast enhanced or non-enhanced CT numbers may potentially be used to monitor thermal ablation with HIFU. Integrated CT, diagnostic US, and therapeutic focused ultrasound bridges a gap between diagnosis and therapy. Preliminary results show that the multimodality system may represent a relatively inexpensive, accessible, and simple method of both targeting and monitoring HIFU effects. Small animal pre-clinical models may be translated to large

  17. Acute diverticulitis of the sigmoid colon: value of ultrasound as an initial diagnostic test

    International Nuclear Information System (INIS)

    Garcia-Aguayo, F. J.; Gil, P. M.

    2002-01-01

    To assess the value of ultrasound as an initial diagnostic method in cases of acute diverticulitis. Ultrasound was carried out in 76 patients with a clinical diagnosis of acute sigmoid diverticulitis. The final diagnosis was based on the clinical course in every case, as well as on computed tomography (CT; n=46), histopathological examination (n=10), colonoscopy (n=4) and barium enema (n=2). The diagnostic criteria established for ultrasound was a thickening of the sigmoid colon wall of >4 mm and the presence of a least one of the following features: diverticular, phlegmon or abscess. The CT diagnosis was based on two indispensable findings: thickening of the sigmoid colon of>4 mm and inflammation of pericolonic fat. The final diagnosis was acute diverticulitis in 52 patients, some other disease in 18 and undetermined in 6. The sensitivities of ultrasound and CT were 81% and 94%, respectively, and their specificities were 79% and 83%, respectively. Of the 10 false negatives on ultrasound, seven corresponded to cases of simple diverticulitis and three to cases of complicated diverticulitis (two in patients with abscess and one in a patient with pneumoperitoneum). CT provided the correct diagnosis in eight of these cases, and resulted in false negatives in two cases of mild diverticulitis. Ultrasound is a valid test in the initial diagnosis of acute diverticulitis of the sigmoid colon. CT should be performed when ultrasound fails to provide a diagnosis or in cases of negative results when there is a strong clinical suspicion of diverticulitis, as well as when the possibility of complicated diverticulitis exists. (Author) 14 refs

  18. An experimental system for the study of ultrasound exposure of isolated blood vessels

    NARCIS (Netherlands)

    Tokarczyk, Anna; Rivens, Ian; van Bavel, E.; Symonds-Tayler, Richard; ter Haar, Gail

    2013-01-01

    An experimental system designed for the study of the effects of diagnostic or therapeutic ultrasound exposure on isolated blood vessels in the presence or absence of intraluminal contrast agent is described. The system comprised several components. A microscope was used to monitor vessel size (and

  19. Diagnostic ultrasound imaging for lateral epicondylalgia: a case-control study.

    Science.gov (United States)

    Heales, Luke James; Broadhurst, Nathan; Mellor, Rebecca; Hodges, Paul William; Vicenzino, Bill

    2014-11-01

    Lateral epicondylalgia (LE) is clinically diagnosed as pain over the lateral elbow that is provoked by gripping. Usually, LE responds well to conservative intervention; however, those who fail such treatment require further evaluation, including musculoskeletal ultrasound. Previous studies of musculoskeletal ultrasound have methodological flaws, such as lack of assessor blinding and failure to control for participant age, sex, and arm dominance. The purpose of this study was to assess the diagnostic use of blinded ultrasound imaging in people with clinically diagnosed LE compared with that in a control group matched for age, sex, and arm dominance. Participants (30 with LE and 30 controls) underwent clinical examination as the criterion standard test. Unilateral LE was defined as pain over the lateral epicondyle, which was provoked by palpation, resisted wrist and finger extension, and gripping. Controls without symptoms were matched for age, sex, and arm dominance. Ultrasound investigations were performed by two sonographers using a standardized protocol. Grayscale images were assessed for signs of tendon pathology and rated on a four-point ordinal scale. Power Doppler was used to assess neovascularity and rated on a five-point ordinal scale. The combination of grayscale and power Doppler imaging revealed an overall sensitivity of 90% and specificity of 47%. The positive and negative likelihood ratios for combined grayscale and power Doppler imaging were 1.69 and 0.21, respectively. Although ultrasound imaging helps confirm the absence of LE, when findings are negative for tendinopathic changes, the high prevalence of tendinopathic changes in pain-free controls challenges the specificity of the measure. The validity of ultrasound imaging to confirm tendon pathology in clinically diagnosed LE requires further study with strong methodology.

  20. Multiparametric ultrasound in the detection of prostate cancer: a systematic review.

    Science.gov (United States)

    Postema, Arnoud; Mischi, Massimo; de la Rosette, Jean; Wijkstra, Hessel

    2015-11-01

    To investigate the advances and clinical results of the different ultrasound modalities and the progress in combining them into multiparametric UltraSound (mpUS). A systematic literature search on mpUS and the different ultrasound modalities included: greyscale ultrasound, computerized transrectal ultrasound, Doppler and power Doppler techniques, dynamic contrast-enhanced ultrasound and (shear wave) elastography. Limited research available on combining ultrasound modalities has presented improvement in diagnostic performance. The data of two studies suggest that even adding a lower performing ultrasound modality to a better performing modality using crude methods can already improve the sensitivity by 13-51 %. The different modalities detect different tumours. No study has tried to combine ultrasound modalities employing a system similar to the PIRADS system used for mpMRI or more advanced classifying algorithms. Available evidence confirms that combining different ultrasound modalities significantly improves diagnostic performance.

  1. ULTRASOUND CRITERIA OF EARLY DIAGNOSTICS OF OVARIAN CARCINOMA

    Directory of Open Access Journals (Sweden)

    L. A. Ashrafyan

    2015-01-01

    Full Text Available Introduction. Ovarian cancer (OC in Russia is ranked the seventh within the structure of general cancer diseases and the third within the gynecological tumors, due to such reasons the problem of early diagnostics is still actual. New technologies, such as color Doppler ultrasonography,3D power Doppler ultrasonography contribute to increasing of opportunities of ultrasound analysis to detect any malignancy signs.Materials and methods. The paper sets out the results of comprehensive ultrasound study of 68 patients with morphologically verified OC at stages IА–В, IIА–В. The control group was made of 100 female patients with morphologically verified ovarian tumors (serosal cystadenomas, thecomas, fibromas. A complex of the following ultrasound methods was used during the study: 2D and 3D ultrasonography in B mode, in color Doppler and power mapping mode, 3D angiography, spectrum Doppler imaging.Results. Maximum size of tumor varied within a range between 37 and 300 mm (108 ± 61.2 mm. It worth noting that no direct dependence between the size of neoplasm and process phase was established. When assessing the echostructure, all ovarian tumors were divided into 3 structure types: cystic type (57.8 % of cases, cystic and solid type (33.3 % of cases, solid type (8.9 % of cases. The conducted analysis of types of small pelvis neoplasm echostructures enabled to evolve the sonographic types of ovarian tumors, more or less associated with the malignant transformation. The most relevanl Doppler ultrasonography exponents characteristic for benignant and malignant processes: resistance index in benignant tumors was 0.56, at OC – 0.32 (р < 0.001; average arterial blood velocity in benignant tumors – 7.8 cm/s, at OC – 20.1 cm/s (р < 0.001; average maximum venous flow velocity in benignant tumors – 3.2 cm/s, at OC – 9.3 cm/s (р < 0.001.Conclusion. Therefore modern ultrasonography can detect and differentiate rather efficiently the localized

  2. Lung ultrasound as a diagnostic tool for radiographically-confirmed pneumonia in low resource settings.

    Science.gov (United States)

    Ellington, Laura E; Gilman, Robert H; Chavez, Miguel A; Pervaiz, Farhan; Marin-Concha, Julio; Compen-Chang, Patricia; Riedel, Stefan; Rodriguez, Shalim J; Gaydos, Charlotte; Hardick, Justin; Tielsch, James M; Steinhoff, Mark; Benson, Jane; May, Evelyn A; Figueroa-Quintanilla, Dante; Checkley, William

    2017-07-01

    Pneumonia is a leading cause of morbidity and mortality in children worldwide; however, its diagnosis can be challenging, especially in settings where skilled clinicians or standard imaging are unavailable. We sought to determine the diagnostic accuracy of lung ultrasound when compared to radiographically-confirmed clinical pediatric pneumonia. Between January 2012 and September 2013, we consecutively enrolled children aged 2-59 months with primary respiratory complaints at the outpatient clinics, emergency department, and inpatient wards of the Instituto Nacional de Salud del Niño in Lima, Peru. All participants underwent clinical evaluation by a pediatrician and lung ultrasonography by one of three general practitioners. We also consecutively enrolled children without respiratory symptoms. Children with respiratory symptoms had a chest radiograph. We obtained ancillary laboratory testing in a subset. Final clinical diagnoses included 453 children with pneumonia, 133 with asthma, 103 with bronchiolitis, and 143 with upper respiratory infections. In total, CXR confirmed the diagnosis in 191 (42%) of 453 children with clinical pneumonia. A consolidation on lung ultrasound, which is our primary endpoint for pneumonia, had a sensitivity of 88.5%, specificity of 100%, and an area under-the-curve of 0.94 (95% CI 0.92-0.97) when compared to radiographically-confirmed clinical pneumonia. When any abnormality on lung ultrasound was compared to radiographically-confirmed clinical pneumonia the sensitivity increased to 92.2% and the specificity decreased to 95.2%, with an area under-the-curve of 0.94 (95% CI 0.91-0.96). Lung ultrasound had high diagnostic accuracy for the diagnosis of radiographically-confirmed pneumonia. Added benefits of lung ultrasound include rapid testing and high inter-rater agreement. Lung ultrasound may serve as an alternative tool for the diagnosis of pediatric pneumonia. Copyright © 2017 The Author(s). Published by Elsevier Ltd.. All rights

  3. Tuberculosis and the pancreas: a diagnostic challenge solved by endoscopic ultrasound. A case series.

    Science.gov (United States)

    Chatterjee, Suvadip; Schmid, Matthias L; Anderson, Kirsty; Oppong, Kofi W

    2012-03-01

    Pancreatic tuberculosis is a rare disease. It can be easily confused with malignancy or pancreatitis on imaging. This could result in unnecessary surgery. As this is a treatable disease it is imperative to diagnose this condition pre-operatively. We report three cases of pancreatic tuberculosis that were diagnosed by endoscopic ultrasound. In conclusion, endoscopic ultrasound is the diagnostic modality of choice for pancreatic tuberculosis facilitating high resolution imaging, as well as sampling of tissue for staining, cytology, culture and polymerase chain reaction assay.

  4. Visualizing and measuring the temperature field produced by medical diagnostic ultrasound using thermography

    International Nuclear Information System (INIS)

    Vachutka, J; Grec, P; Mornstein, V; Caruana, C J

    2008-01-01

    The heating of tissues by diagnostic ultrasound can pose a significant hazard particularly in the imaging of the unborn child. The demonstration of the temperature field in tissue is therefore an important objective in the teaching of biomedical physics to healthcare professionals. The temperature field in a soft tissue model was made visible and measured using thermography. Temperature data from the images were used to investigate the dependence of temperature increase within the model on ultrasound exposure time and distance from the transducer. The experiment will be used within a multi-professional biomedical physics teaching laboratory for enhancing learning regarding the principles of thermography and the thermal effects of ultrasound to medical and healthcare students and also for demonstrating the quantitative use of thermographic imaging to students of biophysics, medical physics and medical technology

  5. Prehospital Ultrasound

    Directory of Open Access Journals (Sweden)

    Jen-Tang Sun

    2014-06-01

    Full Text Available Ultrasound is a commonly used diagnostic tool in clinical conditions. With recent developments in technology, use of portable ultrasound devices has become feasible in prehospital settings. Many studies also proved the feasibility and accuracy of prehospital ultrasound. In this article, we focus on the use of prehospital ultrasound, with emphasis on trauma and chest ultrasound.

  6. Diagnostic ultrasound estimates of muscle mass and muscle quality discriminate between women with and without sarcopenia

    Directory of Open Access Journals (Sweden)

    Catheeja eIsmail

    2015-10-01

    Full Text Available Introduction: Age-related changes in muscle mass and muscle tissue composition contribute to diminished strength in older adults. The objectives of this study are to examine if an assessment method using mobile diagnostic ultrasound augments well-known determinants of lean body mass (LBM to aid sarcopenia staging, and if a sonographic measure of muscle quality is associated with muscle performance.Methods: Twenty community-dwelling female subjects participated in the study (age = 43.4 ±20.9 years; BMI: 23.8, interquartile range: 8.5. Dual energy X-ray absorptiometry (DXA and diagnostic ultrasound morphometry were used to estimate LBM. Muscle tissue quality was estimated via the echogenicity using grayscale histogram analysis. Peak force was measured with grip dynamometry and scaled for body size. Bivariate and multiple regression analyses were used to determine the association of the predictor variables with appendicular lean mass (aLM/ht2, and examine the relationship between scaled peak force values and muscle echogenicity. The sarcopenia LBM cut point value of 6.75 kg/m2 determined participant assignment into the Normal LBM and Low LBM subgroups.Results: The selected LBM predictor variables were body mass index (BMI, ultrasound morphometry, and age. Although BMI exhibited a significant positive relationship with aLM/ht2 (adj. R2 = .61, p < .001, the strength of association improved with the addition of ultrasound morphometry and age as predictor variables (adj. R2 = .85, p < .001. Scaled peak force was associated with age and echogenicity (adj. R2 = .53, p < .001, but not LBM. The Low LBM subgroup of women (n = 10 had higher scaled peak force, lower BMI, and lower echogenicity values in comparison to the Normal LBM subgroup (n = 10; p < .05.Conclusions: Diagnostic ultrasound morphometry values are associated with LBM, and improve the BMI predictive model for aLM/ht2 in women. In addition, ultrasound proxy measures of muscle quality are more

  7. Diagnostic value of CT compared to ultrasound in the evaluation of acute abdominal pain in children younger than 10 years old.

    Science.gov (United States)

    Simanovsky, Natalia; Dola, Tamar; Hiller, Nurith

    2016-02-01

    To assess the diagnostic value of ultrasound compared to CT in evaluating acute abdominal pain of different causes in children 10 years of age and under, hospital records and imaging files of 4052 patients under age of 10 who had imaging for abdominal pain were reviewed. One-hundred-thirty-two patients (3 %), (74 males/58 females) who underwent ultrasound and CT within 24 h were divided by age: group I, ages 0-48 months (25 patients); group II, 49-84 months (53 patients); and group III, 85-120 months (54 patients). Diagnoses at ultrasound, CT, and discharge were compared. Cases of a change in diagnosis following CT and impact of the changed diagnosis on patient management were assessed. Non-diagnostic ultrasound or a diagnostic conundrum was present in a small percentage (3 %) of our patients. In the group of patients imaged with two modalities, CT changed the diagnosis in 73/132 patients (55.3 %). Patient management changed in 63/132 patients (47.7 %). CT changed the diagnosis in 46/64 patients with surgical conditions (71.8 %, p diagnostic or equivocal US in a small percentage of patients is probably sufficient to justify the additional radiation burden.

  8. Evaluation of lymph node status after neoadjuvant chemotherapy in breast cancer patients: comparison of diagnostic performance of ultrasound, MRI and ¹⁸F-FDG PET/CT.

    Science.gov (United States)

    You, S; Kang, D K; Jung, Y S; An, Y-S; Jeon, G S; Kim, T H

    2015-08-01

    To evaluate the diagnostic performance of ultrasound, MRI and fluorine-18 fludeoxyglucose positron emission tomography (¹⁸F-FDG PET)/CT for the diagnosis of metastatic axillary lymph node (ALN) after neoadjuvant chemotherapy (NAC) and to find out histopathological factors affecting the diagnostic performance of these imaging modalities. From January 2012 to November 2014, 191 consecutive patients with breast cancer who underwent NAC before surgery were retrospectively reviewed. We included 139 patients with ALN metastasis that was confirmed on fine needle aspiration or core needle biopsy at initial diagnosis. After NAC, 39 (28%) patients showed negative conversion of ALN on surgical specimens of sentinel lymph node (LN) or ALN. The sensitivity of ultrasound, MRI and PET/CT was 50% (48/96), 72% (70/97) and 22% (16/73), respectively. The specificity of ultrasound, MRI and PET/CT was 77% (30/39), 54% (21/39) and 85% (22/26), respectively. The Az value of combination of ultrasound and PET/CT was the highest (0.634) followed by ultrasound (0.626) and combination of ultrasound, MRI and PET/CT (0.617). The size of tumour deposit in LN and oestrogen receptor was significantly associated with the diagnostic performance of ultrasound (p performance of PET/CT (p = 0.023, p = 0.002, p = 0.036, p = 0.044 and p = 0.008, respectively). On multivariate logistic regression analysis, size of tumour deposit within LN was identified as being independently associated with diagnostic performance of ultrasound [odds ratio, 13.07; 95% confidence interval (CI), 2.95-57.96] and PET/CT (odds ratio, 6.47; 95% CI, 1.407-29.737). Combination of three imaging modalities showed the highest sensitivity, and PET/CT showed the highest specificity for the evaluation of ALN metastasis after NAC. Ultrasound alone or combination of ultrasound and PET/CT showed the highest positive-predictive value. The size of tumour deposit within ALN was significantly associated with

  9. The Thrombolytic Effect of Diagnostic Ultrasound-Induced Microbubble Cavitation in Acute Carotid Thromboembolism.

    Science.gov (United States)

    Porter, Thomas R; Xie, Feng; Lof, John; Powers, Jeffry; Vignon, Francois; Shi, William; White, Matthew

    2017-08-01

    Acute ischemic stroke is often due to thromboembolism forming over ruptured atherosclerotic plaque in the carotid artery (CA). The presence of intraluminal CA thrombus is associated with a high risk of thromboembolic cerebral ischemic events. The cavitation induced by diagnostic ultrasound high mechanical index (MI) impulses applied locally during a commercially available intravenous microbubble infusion has dissolved intravascular thrombi, especially when using longer pulse durations. The beneficial effects of this in acute carotid thromboembolism is not known. An oversized balloon injury was created in the distal extracranial common CA of 38 porcine carotid arteries. After this, a 70% to 80% stenosis was created in the mid common CA proximal to the injury site using partial balloon inflation. Acute thrombotic CA occlusions were created just distal to the balloon catheter by injecting fresh autologous arterial thrombi. After angiographic documentation of occlusion, the common carotid thrombosis was treated with either diagnostic low MI imaging alone (0.2 MI; Philips S5-1) applied through a tissue mimicking phantom (TMP) or intermittent diagnostic high MI stable cavitation (SC)-inducing impulses with a longer pulse duration (0.8 MI; 20 microseconds' pulse duration) or inertial cavitation (IC) impulses (1.2 MI; 20 microseconds' pulse duration). All treatment times were for 30 minutes. Intravenous ultrasound contrast (2% Definity; Lantheus Medical) was infused during the treatment period. Angiographic recanalization in 4 intracranial and extracranial vessels downstream from the CA occlusion (auricular, ascending pharyngeal, buccinator, and maxillary) was assessed with both magnetic resonance 3-dimensional time-of-flight and phase contrast angiography. All magnetic resonance images were interpreted by an independent neuroradiologist using the thrombolysis in cerebral infarction (TICI) scoring system. By phase contrast angiography, at least mild recanalization (TICI 2a

  10. Computed tomography, nuclear medicine, ultrasound. Advanced diagnostic imaging for problematic areas in paediatric otolaryngology

    International Nuclear Information System (INIS)

    Noyek, A.M.; Friedberg, J.; Fitz, C.R.; Greyson, N.D.; Gilday, D.; Ash, J.; Miskin, M.; Rothberg, R.

    1982-01-01

    This presentation considers the diagnostic role of three major advanced imaging modalities in paediatric otolaryngology: computed tomography, nuclear medicine and ultrasound. These techniques allow for both more specific diagnosis, and for more precise understanding of the natural history of diagnoses already rendered. (Auth.)

  11. Comparison of the Diagnostic Performance of Power Doppler Ultrasound and a New Microvascular Doppler Ultrasound Technique (AngioPLUS) for Differentiating Benign and Malignant Breast Masses.

    Science.gov (United States)

    Jung, Hae Kyoung; Park, Ah Young; Ko, Kyung Hee; Koh, Jieun

    2018-03-12

    This study was performed to compare the diagnostic performance of power Doppler ultrasound (US) and a new microvascular Doppler US technique (AngioPLUS; SuperSonic Imagine, Aix-en-Provence, France) for differentiating benign and malignant breast masses. Power Doppler US and AngioPLUS findings were available in 124 breast masses with confirmed pathologic results (benign, 80 [64.5%]; malignant, 44 [35.5%]). The diagnostic performance of each tool was calculated to distinguish benign from malignant masses using a receiver operating characteristic curve analysis and compared. The area under the curve showed that AngioPLUS was superior to power Doppler US in differentiating benign from malignant breast masses, but the difference was not statistically significant. © 2018 by the American Institute of Ultrasound in Medicine.

  12. An ultrasound system for simultaneous ultrasound hyperthermia and photon beam irradiation

    International Nuclear Information System (INIS)

    Straube, William L.; Moros, Eduardo G.; Low, Daniel A.; Klein, Eric E.; Willcut, Virgil M.; Myerson, Robert J.

    1996-01-01

    Purpose: An existing ultrasound system has been adapted for simultaneous use with external photon beam irradiation. The system is being used to investigate the potential for increased biological benefit of simultaneously combined hyperthermia and external beam irradiation with currently achievable temperature distributions. Methods and Materials: An existing clinical ultrasound system has been modified for simultaneous operation with a 60 Co teletherapy machine. The generator, thermometry system, computer, and applicators are located inside the treatment room, while the monitor and system control are located at the control console. Two approaches have been used clinically to combine the two modalities. In the first approach, an en-face setup is used in which the ultrasound beam and the photon beam travel through the same window of entry to the tumor. This is achieved by a reflecting system designed to deflect the ultrasound to the tumor while positioning the ultrasound transducer outside the radiation beam. The reflecting system consists of water and water-equivalent materials except for a 1 mm sheet of polished brass that is used as the reflector. The relative pressure fields were measured in water at the same distance from the ultrasound source using a scanning hydrophone with and without the reflector at the two operating frequencies of the device (1.0 and 3.4 MHz) for two applicators. Radiation dosimetry measurements were performed to determine the relationship between 60 Co irradiation through the reflector and absorbed dose. In the second approach the ultrasound and the radiation beam travel into the tumor from different windows of entry such that the radiation beam passes through no portion of the water bolus prior to entering the patient. We have termed this approach the orthogonal approach. For both approaches, the radiation fraction is given in the middle of an uninterrupted 60-min hyperthermia treatment. Results: The system modifications did not impair

  13. Strain elastography of abnormal axillary nodes in breast cancer patients does not improve diagnostic accuracy compared with conventional ultrasound alone.

    Science.gov (United States)

    Park, Young Mi; Fornage, Bruno D; Benveniste, Ana Paula; Fox, Patricia S; Bassett, Roland L; Yang, Wei Tse

    2014-12-01

    The purpose of this study was to determine the diagnostic value of strain elastography (SE) alone and in combination with gray-scale ultrasound in the diagnosis of benign versus metastatic disease for abnormal axillary lymph nodes in breast cancer patients. Patients with breast cancer and axillary lymph nodes suspicious for metastatic disease on conventional ultrasound who underwent SE of the suspicious node before ultrasound-guided fine-needle aspiration biopsy (FNAB) were included in this study. On conventional ultrasound, the long- and short-axis diameters, long-axis-to-short-axis ratio, cortical echogenicity, thickness, and evenness were documented. The nodal vascularity was assessed on power Doppler imaging. Elastograms were evaluated for the percentage of black (hard) areas in the lymph node, and the SE-ultrasound size ratio was calculated. Two readers assessed the images independently and then in consensus in cases of disagreement. ROC AUCs were calculated for conventional ultrasound, SE, and both methods combined. Interreader reliability was assessed using kappa statistics. A total of 101 patients with 104 nodes were examined; 35 nodes were benign, and 69 had metastases. SE alone showed a significantly lower AUC (62%) than did conventional ultrasound (92%) (pultrasound and the AUC of the combination of conventional ultrasound and SE (93%) (p=0.16). Interreader reliability was moderate for all variables (κ≥0.60) except the SE-ultrasound size ratio (κ=0.35). Added SE does not improve the diagnostic ability of conventional ultrasound when evaluating abnormal axillary lymph nodes.

  14. Diagnostic performance of multi-organ ultrasound with pocket-sized device in the management of acute dyspnea.

    Science.gov (United States)

    Sforza, Alfonso; Mancusi, Costantino; Carlino, Maria Viviana; Buonauro, Agostino; Barozzi, Marco; Romano, Giuseppe; Serra, Sossio; de Simone, Giovanni

    2017-06-19

    The availability of ultra-miniaturized pocket ultrasound devices (PUD) adds diagnostic power to the clinical examination. Information on accuracy of ultrasound with handheld units in immediate differential diagnosis in emergency department (ED) is poor. The aim of this study is to test the usefulness and accuracy of lung ultrasound (LUS) alone or combined with ultrasound of the heart and inferior vena cava (IVC) using a PUD for the differential diagnosis of acute dyspnea (AD). We included 68 patients presenting to the ED of "Maurizio Bufalini" Hospital in Cesena (Italy) for AD. All patients underwent integrated ultrasound examination (IUE) of lung-heart-IVC, using PUD. The series was divided into patients with dyspnea of cardiac or non-cardiac origin. We used 2 × 2 contingency tables to analyze sensitivity, specificity, positive predictive value and negative predictive value of the three ultrasonic methods and their various combinations for the diagnosis of cardiogenic dyspnea (CD), comparing with the final diagnosis made by an independent emergency physician. LUS alone exhibited a good sensitivity (92.6%) and specificity (80.5%). The highest accuracy (90%) for the diagnosis of CD was obtained with the combination of LUS and one of the other two methods (heart or IVC). The IUE with PUD is a useful extension of the clinical examination, can be readily available at the bedside or in ambulance, requires few minutes and has a reliable diagnostic discriminant ability in the setting of AD.

  15. The usefulness of ultrasound in the diagnostics of Sjögren’s syndrome

    Directory of Open Access Journals (Sweden)

    Fadhil Saied

    2013-06-01

    Full Text Available Sjögren’s syndrome is an autoimmune exocrinopathy which manifests itself with dryness of the eyes and the oral cavity. These symptoms comprise a so-called sicca syndrome (xerostomia and xerophthalmia. Two forms of this disease may be distinguished: primary Sjögren’s syndrome which affects salivary glands and secondary Sjögren’s syndrome with other autoimmune diseases present such as rheumatoid arthritis, systemic lupus erythematosus or systemic scleroderma. The diagnosis is based on the classification criteria established in 2002 by a group of American and European scientists (American-European Consensus Group, which involve the interview and physical examination as well as serological, histopathological and radiological tests. Most of these examinations show some limitations such as invasiveness, expensiveness or limited accessibility. The latest research suggests that ultrasound examination may appear promising in the diagnostics of the main salivary glands: submandibular and parotid glands. It is an accessible and relatively cheap examination with high sensitivity and specificity values which are comparable to those obtained via conventional means used in the diagnostics of this disease, i.e. biopsy of the minor salivary glands, sialography and scintigraphy, as well as superior to those obtained in sialometry and Schirmer’s test. Additionally, ultrasonography correlates with the results of magnetic resonance imaging. Therefore, a number of authors claim that US examination should be included in the classification criteria of Sjögren’s syndrome. The aim of this article is to present the diagnostic capacity of the US examination in Sjögren’s syndrome using the current ultrasound classification systems based on the grey-scale, Doppler and contrast-enhanced examinations. The latest research confirms that the most valuable diagnostic criterion in Sjögren’s syndrome is the heterogeneity of the

  16. Ultrasound diagnostics of muscle and tendon injuries

    Directory of Open Access Journals (Sweden)

    Stević Ruža

    2009-01-01

    Full Text Available Introduction. Sonography is a useful technique for the investigation of a number of musculoskeletal disorders. The most common indication for ultrasonography of muscles and tendons is the diagnosis of traumatic lesions, distinguishing them from other disorders and follow-up of healing process. Objective. The purpose of this paper is to show the importance of ultrasound in the diagnosis of muscle and tendon injuries. Methods. The study included 170 patients (148 male and 22 female, mean age 29.6 years (range 14-60 years. All examinations were performed by linear transducer of 7.5-10 MHz, with longitudinal and transverse scanning. Ultrasound examination followed physical examination. Results. Traumatic lesions of muscles were diagnosed in 113 patients (66.7% and tendon injuries in 57 cases (33.2%. The muscle changes detected by ultrasonography were the following: 70 (61.9% partial and two (1.76% complete ruptures, 22 (19.46% haematoma, 9 (7.96% strains grade I, 4 fibroses and 4 ossifying myositis 4 (3.5%, respectively. Complications of muscle injuries were diagnosed in two cases, a muscular hernia and an arteriovenous fistula. Among tendon injuries, 21 (33.8% ruptures and 36 (66.1% tendinitis were diagnosed. Accompanying effusion in the bursa of patients with tendon injuries was found in 9 cases. Conclusion. Ultrasonography allowed visualization and objective assessment of the type and the extent of traumatic pathomorphological changes of muscles and tendons. Such diagnostic possibilities of ultrasonography are especially important in the choice of appropriate therapy.

  17. The diagnostic test accuracy of ultrasound for the detection of lateral epicondylitis: a systematic review and meta-analysis.

    Science.gov (United States)

    Latham, S K; Smith, T O

    2014-05-01

    The purpose of this study was to determine the diagnostic test accuracy of ultrasound for the detection of lateral epicondylitis. An electronic search of databases registering published (MEDLINE, EMBASE, CINAHL, AMED, Cochrane Library, ScienceDirect) and unpublished literature was conducted to January 2013. All diagnostic accuracy studies that compared the accuracy of ultrasound (index test) with a reference standard for lateral epicondylitis were included. The methodological quality of each of the studies was appraised using the QUADAS tool. When appropriate, the pooled sensitivity and specificity analysis was conducted. Ten studies investigating 711 participants and 1077 elbows were included in this review. Ultrasound had variable sensitivity and specificity (sensitivity: 64%-100%; specificity: 36%-100%). The available literature had modest methodological quality, and was limited in terms of sample sizes and blinding between index and reference test results. There is evidence to support the use of ultrasound in the detection of lateral epicondylitis. However, its accuracy appears to be highly dependent on numerous variables, such as operator experience, equipment and stage of pathology. Judgement should be used when considering the benefit of ultrasound for use in clinical practice. Further research assessing variables such a transducer frequency independently is specifically warranted. Level II. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  18. Diagnostic accuracy of ultrasound for rotator cuff tears in adults: A systematic review and meta-analysis

    Energy Technology Data Exchange (ETDEWEB)

    Smith, T.O., E-mail: toby.smith@uea.ac.uk [Department of Physiotherapy, University of East Anglia (United Kingdom); Back, T. [Department of Physiotherapy, Norfolk and Norwich University Hospital, London (United Kingdom); Toms, A.P. [Department of Radiology, Norfolk and Norwich University Hospital, London (United Kingdom); Hing, C.B. [Department of Orthopaedic Surgery, St George' s Hospital, London (United Kingdom)

    2011-11-15

    Aim: To determine the diagnostic accuracy of ultrasound to detect partial and complete thickness rotator cuff tears based on all available clinical trials. Materials and methods: An electronic search of databases registering published and unpublished literature was conducted. All diagnostic accuracy studies that directly compared the accuracy of ultrasound (the index test) to either arthroscopic or open surgical findings (the reference test) for rotator cuff tear were included. The methodological quality of each included study was assessed using the QUADAS form. When appropriate, pooled sensitivity and specificity analysis was conducted, with an assessment of the summary receiver operating characteristic (ROC) curve for each analysis. Results: Sixty-two studies assessing 6007 patients and 6066 shoulders were included. Ultrasonography had good sensitivity and specificity for the assessment of partial thickness (sensitivity 0.84; specificity 0.89), and full-thickness rotator cuff tears (sensitivity 0.96; specificity 0.93). However, the literature poorly described population characteristics, assessor blinding, and was based on limited sample sizes. The literature assessing transducer frequency was particularly small in size. Conclusion: Ultrasonography is an appropriate radiological technique for the assessment of rotator cuff tears with an acceptable sensitivity and specificity. The diagnostic test accuracy of ultrasound is superior for the detection of full-thickness compared to partial-thickness cuff tears. Further study assessing the effect of transducer frequency is warranted.

  19. Diagnostic accuracy of ultrasound for rotator cuff tears in adults: A systematic review and meta-analysis

    International Nuclear Information System (INIS)

    Smith, T.O.; Back, T.; Toms, A.P.; Hing, C.B.

    2011-01-01

    Aim: To determine the diagnostic accuracy of ultrasound to detect partial and complete thickness rotator cuff tears based on all available clinical trials. Materials and methods: An electronic search of databases registering published and unpublished literature was conducted. All diagnostic accuracy studies that directly compared the accuracy of ultrasound (the index test) to either arthroscopic or open surgical findings (the reference test) for rotator cuff tear were included. The methodological quality of each included study was assessed using the QUADAS form. When appropriate, pooled sensitivity and specificity analysis was conducted, with an assessment of the summary receiver operating characteristic (ROC) curve for each analysis. Results: Sixty-two studies assessing 6007 patients and 6066 shoulders were included. Ultrasonography had good sensitivity and specificity for the assessment of partial thickness (sensitivity 0.84; specificity 0.89), and full-thickness rotator cuff tears (sensitivity 0.96; specificity 0.93). However, the literature poorly described population characteristics, assessor blinding, and was based on limited sample sizes. The literature assessing transducer frequency was particularly small in size. Conclusion: Ultrasonography is an appropriate radiological technique for the assessment of rotator cuff tears with an acceptable sensitivity and specificity. The diagnostic test accuracy of ultrasound is superior for the detection of full-thickness compared to partial-thickness cuff tears. Further study assessing the effect of transducer frequency is warranted.

  20. Mammotome biopsy under ultrasound control in the diagnostics and treatment of nodular breast lesions - own experience.

    Science.gov (United States)

    Kibil, Wojciech; Hodorowicz-Zaniewska, Diana; Kulig, Jan

    2012-05-01

    Mammotome biopsy is an effective, minimally invasive, novel technique used in the verification of breast lesions.The aim of the study was to assess the value of ultrasound-guided vacuum-assisted core needle biopsy (mammotome biopsy) in the diagnostics and treatment of nodular breast lesions, considering own data.Material and methods. Analysis comprised 1183 mammotome biopsies under ultrasound control performed in 1177 female patients during the period between 2000 and 2010, at the Regional Clinic for Early Diagnostics and Treatment of Breast Lesions, I Chair and Department of General Surgery, Jagiellonian University, Collegium Medicum.Results. The average patient age amounted to 41.7 years. The size of the investigated lesions ranged between 4 and 65 mm (mean - 12 mm). The histopathological examination result was as follows: fibrocystic lesions (n=285), adenofibroma (n=477), adenosis sclerosans (n=188), hyperplasia without atypy (n=58), phyllode tumor (n=2), papilloma (n=14), hamartoma (n=1), atypical hyperplasia (n=25), in situ ductal carcinoma (n=4), in situ lobular carcinoma (n=5), infiltrating ductal carcinoma (n=114), infiltrating lobular carcinoma (n=4), non-diagnostic result (n=6). The histopathological diagnosis was obtained in 99.5% of cases. Patients diagnosed with atypical hyperplasia or cancer were qualified for surgery, according to accepted standards. The presence of a hematoma was the most common complication after the biopsy, observed in 16.5% of patients.Conclusions. The obtained results confirmed the high value of ultrasound-guided biopsies in the diagnostics of nodular breast lesions. The method is safe, minimally invasive, with few complications, providing a good cosmetic effect. In case of benign lesions with a diameter of less than 15 mm the mammotome biopsy enables to completely excise the lesions, being an alternative to open surgical biopsies. The mammotome biopsy should become the method of choice considering the diagnostics of nodular

  1. 3D ultrasound imaging for prosthesis fabrication and diagnostic imaging

    Energy Technology Data Exchange (ETDEWEB)

    Morimoto, A.K.; Bow, W.J.; Strong, D.S. [and others

    1995-06-01

    The fabrication of a prosthetic socket for a below-the-knee amputee requires knowledge of the underlying bone structure in order to provide pressure relief for sensitive areas and support for load bearing areas. The goal is to enable the residual limb to bear pressure with greater ease and utility. Conventional methods of prosthesis fabrication are based on limited knowledge about the patient`s underlying bone structure. A 3D ultrasound imaging system was developed at Sandia National Laboratories. The imaging system provides information about the location of the bones in the residual limb along with the shape of the skin surface. Computer assisted design (CAD) software can use this data to design prosthetic sockets for amputees. Ultrasound was selected as the imaging modality. A computer model was developed to analyze the effect of the various scanning parameters and to assist in the design of the overall system. The 3D ultrasound imaging system combines off-the-shelf technology for image capturing, custom hardware, and control and image processing software to generate two types of image data -- volumetric and planar. Both volumetric and planar images reveal definition of skin and bone geometry with planar images providing details on muscle fascial planes, muscle/fat interfaces, and blood vessel definition. The 3D ultrasound imaging system was tested on 9 unilateral below-the- knee amputees. Image data was acquired from both the sound limb and the residual limb. The imaging system was operated in both volumetric and planar formats. An x-ray CT (Computed Tomography) scan was performed on each amputee for comparison. Results of the test indicate beneficial use of ultrasound to generate databases for fabrication of prostheses at a lower cost and with better initial fit as compared to manually fabricated prostheses.

  2. Advanced signal processing theory and implementation for sonar, radar, and non-invasive medical diagnostic systems

    CERN Document Server

    Stergiopoulos, Stergios

    2009-01-01

    Integrates topics of signal processing from sonar, radar, and medical system technologies by identifying their concept similarities. This book covers non-invasive medical diagnostic system applications, including intracranial ultrasound, a technology that attempts to address non-invasive detection on brain injuries and stroke.

  3. First steps towards ultrasound-based motion compensation for imaging and therapy: calibration with an optical system and 4D PET imaging

    Directory of Open Access Journals (Sweden)

    Julia eSchwaab

    2015-11-01

    Full Text Available Target motion, particularly in the abdomen, due to respiration or patient movement is still a challenge in many diagnostic and therapeutic processes. Hence, methods to detect and compensate this motion are required. Diagnostic ultrasound represents a non-invasive and dose-free alternative to fluoroscopy, providing more information about internal target motion than respiration belt or optical tracking.The goal of this project is to develop an ultrasound based motion tracking for real time motion correction in radiation therapy and diagnostic imaging, notably in 4D positron emission tomography (PET. In this work, a workflow is established to enable the transformation of ultrasound tracking data to the coordinates of the treatment delivery or imaging system – even if the ultrasound probe is moving due to respiration. It is shown that the ultrasound tracking signal is equally adequate for 4D PET image reconstruction as the clinically used respiration belt and provides additional opportunities in this concern. Furthermore, it is demonstrated that the ultrasound probe being within the PET field of view generally has no relevant influence on the image quality. The accuracy and precision of all the steps in the calibration workflow for ultrasound tracking based 4D PET imaging are found to be in an acceptable range for clinical implementation. Eventually, we show in vitro that an ultrasound based motion tracking in absolute room coordinates with a moving US-transducer is feasible.

  4. TH-A-207B-02: QIBA Ultrasound Elasticity Imaging System Biomarker Qualification and User Testing of Systems

    International Nuclear Information System (INIS)

    Garra, B.

    2016-01-01

    Imaging of tissue elastic properties is a relatively new and powerful approach to one of the oldest and most important diagnostic tools. Imaging of shear wave speed with ultrasound is has been added to most high-end ultrasound systems. Understanding this exciting imaging mode aiding its most effective use in medicine can be a rewarding effort for medical physicists and other medical imaging and treatment professionals. Assuring consistent, quantitative measurements across the many ultrasound systems in a typical imaging department will constitute a major step toward realizing the great potential of this technique and other quantitative imaging. This session will target these two goals with two presentations. A. Basics and Current Implementations of Ultrasound Imaging of Shear Wave Speed and Elasticity - Shigao Chen, Ph.D. Learning objectives-To understand: Introduction: Importance of tissue elasticity measurement Strain vs. shear wave elastography (SWE), beneficial features of SWE The link between shear wave speed and material properties, influence of viscosity Generation of shear waves External vibration (Fibroscan) ultrasound radiation force Point push Supersonic push (Aixplorer) Comb push (GE Logiq E9) Detection of shear waves Motion detection from pulse-echo ultrasound Importance of frame rate for shear wave imaging Plane wave imaging detection How to achieve high effective frame rate using line-by-line scanners Shear wave speed calculation Time to peak Random sample consensus (RANSAC) Cross correlation Sources of bias and variation in SWE Tissue viscosity Transducer compression or internal pressure of organ Reflection of shear waves at boundaries B. Elasticity Imaging System Biomarker Qualification and User Testing of Systems – Brian Garra, M.D. Learning objectives-To understand: Goals Review the need for quantitative medical imaging Provide examples of quantitative imaging biomarkers Acquaint the participant with the purpose of the RSNA Quantitative Imaging

  5. TH-A-207B-02: QIBA Ultrasound Elasticity Imaging System Biomarker Qualification and User Testing of Systems

    Energy Technology Data Exchange (ETDEWEB)

    Garra, B. [FDA, Silver Spring, MD (United States)

    2016-06-15

    Imaging of tissue elastic properties is a relatively new and powerful approach to one of the oldest and most important diagnostic tools. Imaging of shear wave speed with ultrasound is has been added to most high-end ultrasound systems. Understanding this exciting imaging mode aiding its most effective use in medicine can be a rewarding effort for medical physicists and other medical imaging and treatment professionals. Assuring consistent, quantitative measurements across the many ultrasound systems in a typical imaging department will constitute a major step toward realizing the great potential of this technique and other quantitative imaging. This session will target these two goals with two presentations. A. Basics and Current Implementations of Ultrasound Imaging of Shear Wave Speed and Elasticity - Shigao Chen, Ph.D. Learning objectives-To understand: Introduction: Importance of tissue elasticity measurement Strain vs. shear wave elastography (SWE), beneficial features of SWE The link between shear wave speed and material properties, influence of viscosity Generation of shear waves External vibration (Fibroscan) ultrasound radiation force Point push Supersonic push (Aixplorer) Comb push (GE Logiq E9) Detection of shear waves Motion detection from pulse-echo ultrasound Importance of frame rate for shear wave imaging Plane wave imaging detection How to achieve high effective frame rate using line-by-line scanners Shear wave speed calculation Time to peak Random sample consensus (RANSAC) Cross correlation Sources of bias and variation in SWE Tissue viscosity Transducer compression or internal pressure of organ Reflection of shear waves at boundaries B. Elasticity Imaging System Biomarker Qualification and User Testing of Systems – Brian Garra, M.D. Learning objectives-To understand: Goals Review the need for quantitative medical imaging Provide examples of quantitative imaging biomarkers Acquaint the participant with the purpose of the RSNA Quantitative Imaging

  6. High definition ultrasound imaging for battlefield medical applications

    Energy Technology Data Exchange (ETDEWEB)

    Kwok, K.S.; Morimoto, A.K.; Kozlowski, D.M.; Krumm, J.C.; Dickey, F.M. [Sandia National Labs., Albuquerque, NM (United States); Rogers, B; Walsh, N. [Texas Univ. Health Science Center, San Antonio, TX (United States)

    1996-06-23

    A team has developed an improved resolution ultrasound system for low cost diagnostics. This paper describes the development of an ultrasound based imaging system capable of generating 3D images showing surface and subsurface tissue and bone structures. We include results of a comparative study between images obtained from X-Ray Computed Tomography (CT) and ultrasound. We found that the quality of ultrasound images compares favorably with those from CT. Volumetric and surface data extracted from these images were within 7% of the range between ultrasound and CT scans. We also include images of porcine abdominal scans from two different sets of animal trials.

  7. Tele-ultrasound using ATM over a T-1 satellite connection

    Science.gov (United States)

    Williamson, Morgan P.; Suitor, Charles T.; de Treville, Robert E.; Freckleton, Michael W.; Kinsey, Van; Goeringer, Fred; Lyche, David K.; Hunter, Bruce; Jennings, Neal E.; Shelton, Philip D.; Marcy, Jon; Poore, Tom; North, Jack

    1996-04-01

    In September 1995 the United States military conducted a demonstration project to provide live ultrasound video and diagnostic DICOM still images using GTE's asynchronous transfer mode (ATM) technologies over an Orion T-1 satellite link. Still images were frame-grabbed from a Diasonics ultrasound and sent to the ALI Wide Area Network system. A group of diagnostic images was then sent in DICOM 3.0 format over a virtual ethernet satellite link from Chantilly, Virginia to Dayton, Ohio. These images came across a DICOM gateway into the Medical Diagnostic Imaging Support (MDIS) System. Live video from the ultrasound was also routed through a CLI Radiance VTC over the satellite to a VTC in Ohio. The video bandwidth was progressively narrowed with two radiologists determining the minimal acceptable bandwidth for detecting test objects in a phantom. The radiologists accepted live video ultrasound at bandwidths as low as 384 kbps from the hands of an experienced ultrasonographer located hundreds of miles away. DICOM still images were sent uncompressed and were of acceptable image quality when viewed on the MDIS system. The technology demonstrated holds great promise for both deployed U.S. Military Forces and civil uses of remote radiology. Detailed network drawings and videotapes of the ultrasound examinations at the remote site are provided.

  8. Ultrasound-guided diagnostic breast biopsy methodology: retrospective comparison of the 8-gauge vacuum-assisted biopsy approach versus the spring-loaded 14-gauge core biopsy approach

    Science.gov (United States)

    2011-01-01

    Background Ultrasound-guided diagnostic breast biopsy technology represents the current standard of care for the evaluation of indeterminate and suspicious lesions seen on diagnostic breast ultrasound. Yet, there remains much debate as to which particular method of ultrasound-guided diagnostic breast biopsy provides the most accurate and optimal diagnostic information. The aim of the current study was to compare and contrast the 8-gauge vacuum-assisted biopsy approach and the spring-loaded 14-gauge core biopsy approach. Methods A retrospective analysis was done of all ultrasound-guided diagnostic breast biopsy procedures performed by either the 8-gauge vacuum-assisted biopsy approach or the spring-loaded 14-gauge core biopsy approach by a single surgeon from July 2001 through June 2009. Results Among 1443 ultrasound-guided diagnostic breast biopsy procedures performed, 724 (50.2%) were by the 8-gauge vacuum-assisted biopsy technique and 719 (49.8%) were by the spring-loaded 14-gauge core biopsy technique. The total number of false negative cases (i.e., benign findings instead of invasive breast carcinoma) was significantly greater (P = 0.008) in the spring-loaded 14-gauge core biopsy group (8/681, 1.2%) as compared to in the 8-gauge vacuum-assisted biopsy group (0/652, 0%), with an overall false negative rate of 2.1% (8/386) for the spring-loaded 14-gauge core biopsy group as compared to 0% (0/148) for the 8-gauge vacuum-assisted biopsy group. Significantly more (P guided diagnostic breast biopsy procedure. Significantly more (P guided diagnostic breast biopsy procedure. Conclusions In appropriately selected cases, the 8-gauge vacuum-assisted biopsy approach appears to be advantageous to the spring-loaded 14-gauge core biopsy approach for providing the most accurate and optimal diagnostic information. PMID:21835024

  9. Usefulness of diagnostic ultrasound for detecting myofascial change of the hamstring muscles due to lmmobilization: Experimental study with caged rabbits

    International Nuclear Information System (INIS)

    Kang, Yoon Kyoo; Kim, Joo Hyun; Lee, Chang Hyung; Kim, Jung Ryul; Kim, Han Kyum

    2002-01-01

    To evaluate the usefulness of diagnostic ultrasound in the localization of soft tissue changes in the region of clinically suspected myofascial pain syndrome and to investigate the ultrasonographic and pathologic differences of the hamstring muscles between caged and freely mobile rabbits. A total of eight caged rabbits were used in this study. Four rabbits (age; two were 3-4 months, and the other two were 8-9 months) were raised in a small cage (40 X 50 X 30 cm), and the other four rabbits (age; two were 3-4 months while the other two 8-9 months) raised in a yard where they were free to move around. First, clinically identified myofascial trigger point-taut band or nodule was identified followed by diagnostic ultrasound examination of the hamstring and gluteus muscles and injection of Indian ink of the band or nodule. Biopsies were performed to include the hyperechoic regions as well as clinically identified myofascial trigger points, and the obtained specimens were stained with hematoxylin-eosin and masson-trichrome. The analysis of the results of the ultrasound study and pathologic study found correlation between the pathologic identification of myofascial trigger point and diagnostic ultrasound, where palpable nodules of caged animal, older more than younger one should greater extent of increment of echogenicity and degenerative pathologic changes such as fatty changes and appearance of hyaline fibers. Diagnostic ultrasound could be applied to identify or observe soft tissue changes in the regions of clinically identified myofascial trigger points. A pattern has emerged where soft tissue changes were ore likely to be observed in the caged animal where their movements were restricted and prone to fixed position. Further study to investigate the reversibility of pathologic changes of caged animal should be carried out.

  10. [Diagnostic ultrasound in pneumothorax].

    Science.gov (United States)

    Maury, É; Pichereau, C; Bourcier, S; Galbois, A; Lejour, G; Baudel, J-L; Ait-Oufella, H; Guidet, B

    2016-10-01

    For a long time the lung has been regarded as inaccessible to ultrasound. However, recent clinical studies have shown that this organ can be examined by this technique, which appears, in some situations, to be superior to thoracic radiography. The examination does not require special equipment and is possible using a combination of simple qualitative signs: lung sliding, the presence of B lines and the demonstration of the lung point. The lung sliding corresponds to the artefact produced by the movement of the two pleural layers, one against the other. The B lines indicate the presence of an interstitial syndrome. The presence of lung sliding and/or B lines has a negative predictive value of 100% and formally excludes a pneumothorax in the area where the probe has been applied. The presence of the lung point is pathognomonic of pneumothorax but the sensitivity is no more than 60%. Ultrasound is therefore a rapid and simple means of excluding a pneumothorax (lung sliding or B lines) and of confirming a pneumothorax when the lung point is visible. The question that remains is whether ultrasound can totally replace radiography in the management of this disorder. Copyright © 2015 SPLF. Published by Elsevier Masson SAS. All rights reserved.

  11. Doppler ultrasound for diagnosis of soft tissue sarcoma: efficacy of ultrasound-based screening score

    Directory of Open Access Journals (Sweden)

    Nagano Satoshi

    2015-06-01

    Full Text Available Background. The utility of ultrasound imaging in the screening of soft-part tumours (SPTs has been reported. We classified SPTs according to their blood flow pattern on Doppler ultrasound and re-evaluated the efficacy of this imaging modality as a screening method. Additionally, we combined Doppler ultrasound with several values to improve the diagnostic efficacy and to establish a new diagnostic tool.

  12. Prostate Ultrasound

    Medline Plus

    Full Text Available ... top of page What are the benefits vs. risks? Benefits Ultrasound is widely available, easy-to-use ... procedures such as needle biopsies and fluid aspiration. Risks For standard diagnostic ultrasound , there are no known ...

  13. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... Ultrasound is the preferred imaging modality for the diagnosis and monitoring of pregnant women and their unborn ... sexes without x-ray exposure. Risks For standard diagnostic ultrasound , there are no known harmful effects on ...

  14. A comparison between workshop and DVD methods of training for physiotherapists in diagnostic ultrasound

    International Nuclear Information System (INIS)

    McKiernan, Sharmaine; Chiarelli, Pauline; Warren-Forward, Helen

    2012-01-01

    Diagnostic ultrasound has expanded into physiotherapy though training in the modality appears to be and is reported by physiotherapists as limited. To address this, a training package was specifically developed for physiotherapists within Australia. The aim of this study was to evaluate the training package for improved educational outcome and to ascertain if there was a difference in outcome between two forms of delivery. The training package was delivered either during a workshop, where the training package was delivered face to face, or via a self paced DVD, which was mailed to participants. Both participant groups completed a web based assessment prior to and at the completion of the training. The assessment assessed their knowledge in ultrasound physics, scanning technique and anatomy. Pre and post training assessment scores were available for 84 participants who attended a workshop and 96 participants who received the DVD. Important and statistically significant (p < 0.05) increases in assessment scores from the beginning to the end of the training program were seen in both groups. On average, workshop participant scores improved by 37% and DVD participant scores improved by 27%. No statistical difference in the post assessment scores of the workshop trained or DVD trained participants was evident. On comparison, no statistically significant difference between the two methods of training; workshop and DVD, was found so both can be seen to be beneficial to the professional development of the physiotherapist in the use of diagnostic ultrasound within their profession.

  15. Patient-exposure data for doppler ultrasound

    International Nuclear Information System (INIS)

    Stewart, H.F.; Silvis, P.X.; Smith, S.W.

    1986-01-01

    In recent years ultrasound imaging and Doppler blood flow measurements have become important tools for use in diagnostic medicine. Commercial pulse-echo imaging equipment was first introduced into commerce in 1963. The first commercial continuous wave Doppler unit was introduced to the marketplace in 1966. As equipment improved and applications developed, the industry experienced rapid growth in the 1970s. One of the more recent growth areas in the application of diagnostic ultrasound has been the use of pulsed Doppler equipment for cardiac applications. Prior to 1976, some continuous wave Doppler ultrasound was used for cardiovascular diagnosis. However, only a single manufacturer marketed a pulsed Doppler clinical instrument for cardiac or peripheral vascular diagnosis. Currently, many continuous wave and pulsed Doppler instruments are commercially available for both peripheral vascular and cardiac diagnosis. This chapter (1) briefly reviews current safety guidelines, regulations, and recommendations for diagnostic ultrasound; (2) discusses the patient-exposure intensities associated with Doppler ultrasound medical equipment and compare these levels of exposure with intensities from other medical ultrasound devices; and (3) considers some of the current information as it relates to the safety of diagnostic ultrasound

  16. Agreement Between an Automated Volume Breast Scanner and Handheld Ultrasound for Diagnostic Breast Examinations.

    Science.gov (United States)

    Barr, Richard G; DeVita, Robert; Destounis, Stamatia; Manzoni, Federica; De Silvestri, Annalisa; Tinelli, Carmine

    2017-10-01

    To compare the agreement and interobserver variability of diagnostic handheld ultrasound (US) and a single volume on an automated breast volume scanner (ABVS) and to determine whether there was a significant difference if the ABVS was used by a sonographer or mammographic technologist. Ninety patients scheduled for diagnostic US examinations were randomized to either handheld US or the ABVS first. The AVBS was randomized between a sonographer and a mammographic technologist performing the study. The studies were blinded, randomized, and read by 2 radiologists. The lesion with the highest Breast Imaging Reporting and Data System (BI-RADS) score was used in the analysis. Final diagnoses were made by core biopsy or follow-up for 2 years. Lesions included 9 malignant and 81 benign. The 90 patients had a mean age ± SD of 53.1 ± 16.3 years. The κ value for agreement between the ABVS and handheld US was 0.831 (95% confidence interval, 0.744-0.925), whereas the global agreement for a 7-point BI-RADS score was 0.488 (0.372-0.560). The agreement between the ABVS and handheld US was nearly the same when the ABVS was used by a mammographic technologist (κ = 0.858 [0.723-0.963]) or sonographer (κ = 0.803 [0.596-1.000]; P = .47). The areas under the receiver operating characteristic curves for characterization by the ABVS were 0.91 (0.84-0.96) for reader 1 and 0.91 (0.83-0.96) for reader 2; those for handheld US were 0.91 (0.84-0.96) for reader 1 and 0.83 (0.74-0.90) for reader 2, with no statistical difference. The agreement based on pathologic images was κ = 0.831 (0.718-0.944); for handheld US, κ = 0.795 (0.623-0.967); and for the AVBS, κ = 0.869 (0.725-1.000). Performing a single-view diagnostic ABVS examination has good agreement with a handheld diagnostic US workup. There is no difference if the ABVS is used by a sonographer or mammographic technologist. © 2017 by the American Institute of Ultrasound in Medicine.

  17. Focused ultrasound in ophthalmology

    Directory of Open Access Journals (Sweden)

    Silverman RH

    2016-09-01

    Full Text Available Ronald H Silverman1,2 1Department of Ophthalmology, Columbia University Medical Center, 2F.L. Lizzi Center for Biomedical Engineering, Riverside Research, New York, NY, USA Abstract: The use of focused ultrasound to obtain diagnostically significant information about the eye goes back to the 1950s. This review describes the historical and technological development of ophthalmic ultrasound and its clinical application and impact. Ultrasound, like light, can be focused, which is crucial for formation of high-resolution, diagnostically useful images. Focused, single-element, mechanically scanned transducers are most common in ophthalmology. Specially designed transducers have been used to generate focused, high-intensity ultrasound that through thermal effects has been used to treat glaucoma (via cilio-destruction, tumors, and other pathologies. Linear and annular transducer arrays offer synthetic focusing in which precise timing of the excitation of independently addressable array elements allows formation of a converging wavefront to create a focus at one or more programmable depths. Most recently, linear array-based plane-wave ultrasound, in which the array emits an unfocused wavefront and focusing is performed solely on received data, has been demonstrated for imaging ocular anatomy and blood flow. While the history of ophthalmic ultrasound extends back over half-a-century, new and powerful technologic advances continue to be made, offering the prospect of novel diagnostic capabilities. Keywords: ophthalmic ultrasound, ultrasound biomicroscopy (UBM, high-intensity focused ultrasound (HIFU, ultrafast imaging, Doppler imaging 

  18. Accuracy of diagnostic ultrasound in patients with suspected subacromial disorders: a systematic review and meta-analysis.

    NARCIS (Netherlands)

    Ottenheijm, R.P.; Jansen, M.J.; Staal, J.B.; Bruel, A. van den; Weijers, R.E.; Bie, R.A. de; Dinant, G.J.

    2010-01-01

    OBJECTIVE: To determine the diagnostic accuracy of ultrasound for detecting subacromial disorders in patients presenting in primary and secondary care settings. DATA SOURCES: Medline and Embase were searched on June 9, 2010. In addition, the reference list of 1 systematic review and all included

  19. Temperature measurement by thermal strain imaging with diagnostic power ultrasound, with potential for thermal index determination.

    Science.gov (United States)

    Liang, Hai-Dong; Zhou, Li-Xia; Wells, Peter N T; Halliwell, Michael

    2009-05-01

    Over the years, there has been a substantial increase in acoustic exposure in diagnostic ultrasound as new imaging modalities with higher intensities and frame rates have been introduced; and more electronic components have been packed into the probe head, so that there is a tendency for it to become hotter. With respect to potential thermal effects, including those which may be hazardous occurring during ultrasound scanning, there is a correspondingly growing need for in vivo techniques to guide the operator as to the actual temperature rise occurring in the examined tissues. Therefore, an in vivo temperature estimator would be of considerable practical value. The commonly-used method of tissue thermal index (TI) measurement with a hydrophone in water could underestimate the actual value of TI (in one report by as much as 2.9 times). To obtain meaningful results, it is necessary to map the temperature elevation in 2-D (or 3-D) space. We present methodology, results and validation of a 2-D spatial and temporal thermal strain ultrasound temperature estimation technique in phantoms, and its apparently novel application in tracking the evolution of heat deposition at diagnostic exposure levels. The same ultrasound probe is used for both transmission and reception. The displacement and thermal strain estimation methods are similar to those used in high-intensity focused ultrasound thermal monitoring. The use of radiofrequency signals permits the application of cross correlation as a similarity measurement for tracking feature displacement. The displacement is used to calculate the thermal strain directly related to the temperature rise. Good agreement was observed between the temperature rise and the ultrasound power and scan duration. Thermal strain up to 1.4% was observed during 4000-s scan. Based on the results obtained for the temperature range studied in this work, the technique demonstrates potential for applicability in phantom (and possibly in vivo tissue

  20. An experimental system for the study of ultrasound exposure of isolated blood vessels

    International Nuclear Information System (INIS)

    Tokarczyk, Anna; Rivens, Ian; Symonds-Tayler, Richard; Ter Haar, Gail; Van Bavel, E

    2013-01-01

    An experimental system designed for the study of the effects of diagnostic or therapeutic ultrasound exposure on isolated blood vessels in the presence or absence of intraluminal contrast agent is described. The system comprised several components. A microscope was used to monitor vessel size (and thus vessel functionality), and potential leakage of intraluminal 70 kDa FITC-dextran fluorescence marker. A vessel chamber allowed the mounting of an isolated vessel whilst maintaining its viability, with pressure regulation for the control of intraluminal pressure and induction of flow for the infusion of contrast microbubbles. A fibre-optic hydrophone sensor mounted on the vessel chamber using a micromanipulator allowed pre-exposure targeting of the vessel to within 150 µm, and monitoring of acoustic cavitation emissions during exposures. Acoustic cavitation was also detected using changes in the ultrasound drive voltage and by detection of audible emissions using a submerged microphone. The suitability of this system for studying effects in the isolated vessel model has been demonstrated using a pilot study of 6 sham exposed and 18 high intensity focused ultrasound exposed vessels, with or without intraluminal contrast agent (SonoVue) within the vessels. (paper)

  1. [Ultrasound of the urinary system].

    Science.gov (United States)

    Segura-Grau, A; Herzog, R; Díaz-Rodriguez, N; Segura-Cabral, J M

    2016-09-01

    Ultrasound techniques are able to provide a fairly complete examination of the urinary system, achieving a high sensitivity in relevant-pathology detection, especially in the kidney, bladder and prostate. Early detection of pathologies such as tumors or urinary tract obstructions, sometimes even before their clinical manifestation, has improved their management and prognosis in many cases. This, added to its low cost and harmlessness, makes ultrasound ideal for early approaches and follow-up of a wide number of urinary system pathologies. In this article, the ultrasound characteristics of the main urinary system pathologies that can be diagnosed by this technique, are reviewed. Copyright © 2014 Sociedad Española de Médicos de Atención Primaria (SEMERGEN). Publicado por Elsevier España, S.L.U. All rights reserved.

  2. Comparing diagnostic accuracy of bedside ultrasound and radiography for bone fracture screening in multiple trauma patients at the ED.

    Science.gov (United States)

    Bolandparvaz, Shahram; Moharamzadeh, Payman; Jamali, Kazem; Pouraghaei, Mahboob; Fadaie, Maryam; Sefidbakht, Sepideh; Shahsavari, Kavous

    2013-11-01

    Long bone fractures are currently diagnosed using radiography, but radiography has some disadvantages (radiation and being time consuming). The present study compared the diagnostic accuracy of bedside ultrasound and radiography in multiple trauma patients at the emergency department (ED). The study assessed 80 injured patients with multiple trauma from February 2011 to July 2012. The patients were older than 18 years and triaged to the cardiopulmonary resuscitation ward of the ED. Bedside ultrasound and radiography were conducted for them. The findings were separately and blindly assessed by 2 radiologists. Sensitivity, specificity, the positive and negative predictive value, and κ coefficient were measured to assess the accuracy and validity of ultrasound as compared with radiography. The sensitivity of ultrasound for diagnosis of limb bone fractures was not high enough and ranged between 55% and 75% depending on the fracture site. The specificity of this diagnostic method had an acceptable range of 62% to 84%. Ultrasound negative prediction value was higher than other indices under study and ranged between 73% and 83%, but its positive prediction value varied between 33.3% and 71%. The κ coefficient for diagnosis of long bone fractures of upper limb (κ = 0.58) and upper limb joints (κ = 0.47) and long bones of lower limb (κ = 0.52) was within the medium range. However, the value for diagnosing fractures of lower limb joints (κ = 0.47) was relatively low. Bedside ultrasound is not a reliable method for diagnosing fractures of upper and lower limb bones compared with radiography. © 2013 Elsevier Inc. All rights reserved.

  3. OSPACS: Ultrasound image management system

    Directory of Open Access Journals (Sweden)

    Bessant Conrad

    2008-06-01

    Full Text Available Abstract Background Ultrasound scanning uses the medical imaging format, DICOM, for electronically storing the images and data associated with a particular scan. Large health care facilities typically use a picture archiving and communication system (PACS for storing and retrieving such images. However, these systems are usually not suitable for managing large collections of anonymized ultrasound images gathered during a clinical screening trial. Results We have developed a system enabling the accurate archiving and management of ultrasound images gathered during a clinical screening trial. It is based upon a Windows application utilizing an open-source DICOM image viewer and a relational database. The system automates the bulk import of DICOM files from removable media by cross-validating the patient information against an external database, anonymizing the data as well as the image, and then storing the contents of the file as a field in a database record. These image records may then be retrieved from the database and presented in a tree-view control so that the user can select particular images for display in a DICOM viewer or export them to external media. Conclusion This system provides error-free automation of ultrasound image archiving and management, suitable for use in a clinical trial. An open-source project has been established to promote continued development of the system.

  4. Ultrasound in Space Medicine

    Science.gov (United States)

    Dulchavsky, Scott A.; Sargsyan, A.E.

    2009-01-01

    This slide presentation reviews the use of ultrasound as a diagnostic tool in microgravity environments. The goals of research in ultrasound usage in space environments are: (1) Determine accuracy of ultrasound in novel clinical conditions. (2) Determine optimal training methodologies, (3) Determine microgravity associated changes and (4) Develop intuitive ultrasound catalog to enhance autonomous medical care. Also uses of Ultrasound technology in terrestrial applications are reviewed.

  5. Diagnostic value of chest ultrasound after cardiac surgery: a comparison with chest X-ray and auscultation.

    Science.gov (United States)

    Vezzani, Antonella; Manca, Tullio; Brusasco, Claudia; Santori, Gregorio; Valentino, Massimo; Nicolini, Francesco; Molardi, Alberto; Gherli, Tiziano; Corradi, Francesco

    2014-12-01

    Chest auscultation and chest x-ray commonly are used to detect postoperative abnormalities and complications in patients admitted to intensive care after cardiac surgery. The aim of the study was to evaluate whether chest ultrasound represents an effective alternative to bedside chest x-ray to identify early postoperative abnormalities. Diagnostic accuracy of chest auscultation and chest ultrasound were compared in identifying individual abnormalities detected by chest x-ray, considered the reference method. Cardiac surgery intensive care unit. One hundred fifty-one consecutive adult patients undergoing cardiac surgery. All patients included were studied by chest auscultation, ultrasound, and x-ray upon admission to intensive care after cardiac surgery. Six lung pathologic changes and endotracheal tube malposition were found. There was a highly significant correlation between abnormalities detected by chest ultrasound and x-ray (k = 0.90), but a poor correlation between chest auscultation and x-ray abnormalities (k = 0.15). Chest auscultation may help identify endotracheal tube misplacement and tension pneumothorax but it may miss most major abnormalities. Chest ultrasound represents a valid alternative to chest x-ray to detect most postoperative abnormalities and misplacements. Copyright © 2014 Elsevier Inc. All rights reserved.

  6. Prenatal Sex Selection and Missing Girls in China: Evidence from the Diffusion of Diagnostic Ultrasound

    Science.gov (United States)

    Chen, Yuyu; Li, Hongbin; Meng, Lingsheng

    2013-01-01

    How much of the increase in sex ratio (male to female) at birth since the early 1980s in China is attributed to increased prenatal sex selection? This question is addressed by exploiting the differential introduction of diagnostic ultrasound in the country during the 1980s, which significantly reduced the cost of prenatal sex selection. We…

  7. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... top of page What are the benefits vs. risks? Benefits Most ultrasound scanning is noninvasive (no needles ... procedures such as needle biopsies and fluid aspiration. Risks For standard diagnostic ultrasound , there are no known ...

  8. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... Ultrasound is the preferred imaging modality for the diagnosis and monitoring of pregnant women and their unborn ... needle biopsies and fluid aspiration. Risks For standard diagnostic ultrasound , there are no known harmful effects on ...

  9. A comparison of hepatic steatosis index, controlled attenuation parameter and ultrasound as noninvasive diagnostic tools for steatosis in chronic hepatitis B.

    Science.gov (United States)

    Xu, Liang; Lu, Wei; Li, Ping; Shen, Feng; Mi, Yu-Qiang; Fan, Jian-Gao

    2017-08-01

    To evaluate the value of noninvasive tools for diagnosis of hepatic steatosis in patients with chronic hepatitis B (CHB). Consecutive treatment-naïve patients with CHB with body mass index less than 30kg/m 2 who underwent liver biopsy, ultrasound and FibroScan ® were enrolled. The diagnostic performance of controlled attenuation parameter (CAP), hepatic steatosis index (HSI) and ultrasound for hepatic steatosis compared with liver biopsy was assessed. The areas under receiver operating characteristics curves (AUROCs) were calculated to determine the diagnostic efficacy, with comparisons using the DeLong test. CAP and HSI accuracies were significantly higher than that of ultrasound to detect patients with biopsy-proven mild steatosis (S1, 65.3%, 56.5%, respectively, vs. 17.7%, χ 2 =46.305, 31.736, both Psteatosis (92.3%, 100%, respectively, vs. 53.8%, χ 2 =4.887, 7.800, P=0.037, 0.007, respectively). Both CAP and HSI had lower underestimation rates of steatosis grade than ultrasound (12%, 14.8%, respectively, vs. 29.5%, χ 2 =9.765, 6.452; Phepatic steatosis than HSI and ultrasound in patients with CHB, but further studies are needed to reduce the overestimation rates. Copyright © 2017 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.

  10. Thyroid Ultrasound: Change of Inter-observer Variability and Diagnostic Performance after Training

    International Nuclear Information System (INIS)

    Moon, Hee Jung; Kim, Eun Kyung; Kwak, Jin Young; Park, Jeong Seon

    2011-01-01

    To investigate and compare inter-observer variability and diagnostic performance of thyroid ultrasound (US) between a faculty member and observing residents. From October 2007 to June 2009, 18 residents underwent training in thyroid US section. Group 1 included 8 residents that were trained for the first time and group 2 included 10 residents that were trained for the second time. US features of nodules were recorded according to the composition, echogenicity, margin, calcifications, shape, and final assessment by a faculty member and residents, respectively. Following a discussion, a faculty member performed fine needle aspiration. Then, the inter-observer variability and diagnostic performance between a faculty member and residents were investigated and compared for US. In group 1, agreement for composition in resident 1, calcification for residents 5 and 6, and shape for resident 4 were slight, moderate, moderate, and moderate, respectively. In group 2, agreement for composition in residents 1 and 10 were moderate. Substantial or greater agreement was observed more frequently in group 2 than 1. The diagnostic performances for both the faculty and residents were high and not statistically different. Agreement for US features between a faculty and residents as well as diagnostic performance were high. Moreover, diagnostic performance of residents that underwent training a second time of training was higher than residents that underwent training only once

  11. Prostate ultrasound imaging: evaluation of a two-step scoring system in the diagnosis of prostate cancer.

    Science.gov (United States)

    Gao, Yong; Liao, Xin-Hong; Ma, Yan; Lu, Lu; Wei, Li-Yan; Yan, Xue

    2017-12-01

    This study aims to investigate the feasibility and performance of a two-step scoring system of ultrasound imaging in the diagnosis of prostate cancer. 75 patients with 888 consecutive histopathologically verified lesions were included in this study. Step 1, an initial 5-point scoring system was developed based on conventional transrectal ultrasound (TRUS). Step 2, a final scoring system was evaluated according to contrast-enhanced transrectal ultrasound (CE-TRUS). Each lesion was evaluated using the two-step scoring system (step 1 + step 2) and compared with only using conventional TRUS (step 1). 888 lesions were histologically verified: 315 of them were prostate cancer from 46 patients and 573 were benign prostatic hypertrophy (BPH) from 29 patients. According to the two-step scoring system, 284 lesions were upgraded and 130 lesions were downgraded from step 1 to step 2 (this means using step 2 to assess the results by step 1). However, 96 cases were improperly upgraded after step 2 and 48 malignant lesions were still missed after step 2 as score-1. For the two-step scoring system, the sensitivity, specificity, and accuracy were 84.7%, 83.2%, and 83.7%, respectively, versus 22.8%, 96.6%, and 70.4%, respectively, for conventional TRUS. The area under the ROC curve (AUC) for lesion diagnosis was 0.799-0.952 for the two-step scoring system, versus 0.479-0.712 for conventional TRUS. The difference in the diagnostic accuracy of the two-step scoring system and conventional TRUS was statistically significant (Pstep scoring system was straightforward to use and achieved a considerably accurate diagnostic performance for prostate cancer. The application of the two-step scoring system for prostate cancer is promising.

  12. Smart Ultrasound Remote Guidance Experiment (SURGE) Preliminary Findings

    Science.gov (United States)

    Hurst, Victor; Dulchavsky, Scott; Garcia, Kathleen; Sargsyan, Ashot; Ebert, Doug

    2009-01-01

    To date, diagnostic quality ultrasound images were obtained aboard the International Space Station (ISS) using the ultrasound of the Human Research Facility (HRF) rack in the Laboratory module. Through the Advanced Diagnostic Ultrasound in Microgravity (ADUM) and the Braslet-M Occlusion Cuffs (BRASLET SDTO) studies, non-expert ultrasound operators aboard the ISS have performed cardiac, thoracic, abdominal, vascular, ocular, and musculoskeletal ultrasound assessments using remote guidance from ground-based ultrasound experts. With exploration class missions to the lunar and Martian surfaces on the horizon, crew medical officers will necessarily need to operate with greater autonomy given communication delays (round trip times of up to 5 seconds for the Moon and 90 minutes for Mars) and longer periods of communication blackouts (due to orbital constraints of communication assets). The SURGE project explored the feasibility and training requirements of having non-expert ultrasound operators perform autonomous ultrasound assessments in a simulated exploration mission outpost. The project aimed to identify experience, training, and human factors requirements for crew medical officers to perform autonomous ultrasonography. All of these aims pertained to the following risks from the NASA Bioastronautics Road Map: 1) Risk 18: Major Illness and Trauna; 2) Risk 20) Ambulatory Care; 3) Risk 22: Medical Informatics, Technologies, and Support Systems; and 4) Risk 23: Medical Skill Training and Maintenance.

  13. Real-time image fusion involving diagnostic ultrasound

    DEFF Research Database (Denmark)

    Ewertsen, Caroline; Săftoiu, Adrian; Gruionu, Lucian G

    2013-01-01

    The aim of our article is to give an overview of the current and future possibilities of real-time image fusion involving ultrasound. We present a review of the existing English-language peer-reviewed literature assessing this technique, which covers technical solutions (for ultrasound...

  14. Security of patient data when decommissioning ultrasound systems.

    Science.gov (United States)

    Moggridge, James

    2017-02-01

    Although ultrasound systems generally archive to Picture Archiving and Communication Systems (PACS), their archiving workflow typically involves storage to an internal hard disk before data are transferred onwards. Deleting records from the local system will delete entries in the database and from the file allocation table or equivalent but, as with a PC, files can be recovered. Great care is taken with disposal of media from a healthcare organisation to prevent data breaches, but ultrasound systems are routinely returned to lease companies, sold on or donated to third parties without such controls. In this project, five methods of hard disk erasure were tested on nine ultrasound systems being decommissioned: the system's own delete function; full reinstallation of system software; the manufacturer's own disk wiping service; open source disk wiping software for full and just blank space erasure. Attempts were then made to recover data using open source recovery tools. All methods deleted patient data as viewable from the ultrasound system and from browsing the disk from a PC. However, patient identifiable data (PID) could be recovered following the system's own deletion and the reinstallation methods. No PID could be recovered after using the manufacturer's wiping service or the open source wiping software. The typical method of reinstalling an ultrasound system's software may not prevent PID from being recovered. When transferring ownership, care should be taken that an ultrasound system's hard disk has been wiped to a sufficient level, particularly if the scanner is to be returned with approved parts and in a fully working state.

  15. A passive wireless ultrasound pitch–catch system

    International Nuclear Information System (INIS)

    Zahedi, F; Yao, J; Huang, H

    2015-01-01

    This paper exploits amplitude modulation and demodulation to achieve a passive wireless ultrasound pitch–catch system consisting of a wireless interrogator and a combination of a wireless actuator and a sensor mounted on a structure. The wireless interrogator operates in two modes, i.e. the generation and sensing modes. At the generation mode, the interrogator transmits two microwave signals; one is amplitude modulated with the ultrasound excitation signal while the other is a continuous-wave carrier signal. Once received by the wireless actuator, the amplitude modulated signal is demodulated using the carrier signal to recover the ultrasound excitation signal, which is then supplied to a piezoelectric wafer actuator for ultrasound generation. Subsequently, the interrogator is switched to the sensing mode by transmitting a carrier signal with a different frequency. Once received by the wireless sensor, this carrier signal is modulated with the ultrasound sensing signal acquired by the piezoelectric wafer sensor to produce an amplitude modulated microwave signal, which can then be wirelessly transmitted and demodulated by the interrogator to recover the original ultrasound sensing signal. The principle and implementation of the wireless ultrasound pitch–catch system as well as the data processing of the wirelessly received sensing signal are described. Experiment results validating wireless ultrasound generation and sensing from a distance of 0.5 m are presented. (paper)

  16. Do Anesthetic Techniques Influence the Threshold for Glomerular Capillary Hemorrhage Induced in Rats by Contrast-Enhanced Diagnostic Ultrasound?

    Science.gov (United States)

    Miller, Douglas L; Lu, Xiaofang; Fabiilli, Mario; Dou, Chunyan

    2016-02-01

    Glomerular capillary hemorrhage can be induced by ultrasonic cavitation during contrast-enhanced diagnostic ultrasound (US) exposure, an important nonthermal US bioeffect. Recent studies of pulmonary US exposure have shown that thresholds for another nonthermal bioeffect of US, pulmonary capillary hemorrhage, is strongly influenced by whether xylazine is included in the specific anesthetic technique. The objective of this study was to determine the influence of xylazine on contrast-enhanced diagnostic US-induced glomerular capillary hemorrhage. In this study, anesthesia with ketamine only was compared to ketamine plus xylazine for induction of glomerular capillary hemorrhage in rats by 1.6-MHz intermittent diagnostic US with a microsphere contrast agent (similar to Definity; Lantheus Medical Imaging, Inc, North Billerica, MA). Glomerular capillary hemorrhage was measured as a percentage of glomeruli with hemorrhage found in histologic sections for groups of rats scanned at different peak rarefactional pressure amplitudes. There was a significant difference between the magnitude of the glomerular capillary hemorrhage between the anesthetics at 2.3 MPa, with 45.6% hemorrhage for ketamine only, increasing to 63.2% hemorrhage for ketamine plus xylazine (P Ultrasound in Medicine.

  17. The Safety of Using High Frequency, Low Intensity Ultrasound to Enhance Thrombolysis

    International Nuclear Information System (INIS)

    Soltani, Azita

    2006-01-01

    The EKOS Ultrasound Infusion Systems (EKOS Corporation, Bothell, WA) use high frequency, low intensity ultrasound to accelerate thrombolysis by enhancing clot permeability and lytic drug penetration into thrombus. These systems are designed to provide efficacious catheter-directed treatment for the management of stroke, peripheral arterial occlusion and deep vein thrombosis. The in vitro and in vivo results of investigating the stability of therapeutic and diagnostic compounds used in combination with EKOS devices, the potential for adverse biological effects and the clot fragmentation confirmed the safety of EKOS ultrasound infusion systems in thrombolysis treatment

  18. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... women and their unborn babies. Ultrasound provides real-time imaging, making it a good tool for guiding minimally invasive procedures such as needle biopsies and fluid aspiration. Risks For standard diagnostic ultrasound , there are no known harmful effects on humans. top of page What are the ...

  19. Mammography and ultrasound in the evaluation of male breast disease

    Energy Technology Data Exchange (ETDEWEB)

    Munoz Carrasco, Rafaela; Alvarez Benito, Marina; Raya Povedano, Jose Luis [Hospital Universitario ' Reina Sofia' , Radiology Department, Cordoba (Spain); Munoz Gomariz, Elisa [Hospital Universitario ' Reina Sofia' , Support Unit for Research, Cordoba (Spain); Martinez Paredes, Maria [University of Cordoba, Radiology and Physical Medicine Area, Cordoba (Spain)

    2010-12-15

    To assess clinical variables that may be useful in differentiating gynaecomastia from carcinoma and to analyse the contribution of mammography and ultrasound to the evaluation of male breast disease. All men who underwent mammography and/or ultrasound between 1993 and 2006 in our hospital were retrospectively evaluated. Clinical characteristics in patients with gynaecomastia and those with carcinoma were compared. Radiological findings were classified according to the BI-RADS (Breast Imaging Reporting and Data System) criteria. The diagnostic performance of physical examination, mammography and ultrasound was determined and compared. A total of 628 patients with 518 mammograms and 423 ultrasounds were reviewed. The final diagnoses were: 19 carcinomas, 526 gynaecomastias, 84 other benign conditions and 25 normal. There were statistically significant differences in age, bilateral involvement, clinical presentation and physical examination between patients with carcinoma and those with gynaecomastia. The diagnostic performance of physical examination was lower than that of mammography and ultrasound (p < 0.05 for specificity). Mammography was the most sensitive (94.7%) and ultrasound the most specific (95.3%) for detection of malignancy (p > 0.05). We propose an algorithm for the use of mammography and ultrasound in men. Mammography and ultrasound, with a negative predictive value close to 100%, make it possible to avoid very many unnecessary surgical procedures in men. (orig.)

  20. Ultrasound elastography as an objective diagnostic measurement tool for lymphoedema of the treated breast in breast cancer patients following breast conserving surgery and radiotherapy

    International Nuclear Information System (INIS)

    Adriaenssens, Nele; Belsack, Dries; Buyl, Ronald; Ruggiero, Leonardo; Breucq, Catherine; De Mey, Johan; Lievens, Pierre; Lamote, Jan

    2012-01-01

    Lymphoedema of the operated and irradiated breast is a common complication following early breast cancer treatment. There is no consensus on objective diagnostic criteria and standard measurement tools. This study investigates the use of ultrasound elastography as an objective quantitative measurement tool for the diagnosis of parenchymal breast oedema. The elasticity ratio of the subcutis, measured with ultrasound elastography, was compared with high-frequency ultrasound parameters and subjective symptoms in twenty patients, bilaterally, prior to and following breast conserving surgery and breast irradiation. Elasticity ratio of the subcutis of the operated breast following radiation therapy increased in 88.9% of patients, was significantly higher than prior to surgery, unlike the non operated breast and significantly higher than the non operated breast, unlike preoperative results. These results were significantly correlated with visibility of the echogenic line, measured with high-frequency ultrasound. Big preoperative bra cup size was a significant risk factor for the development of breast oedema. Ultrasound elastography is an objective quantitative measurement tool for the diagnosis of parenchymal breast oedema, in combination with other objective diagnostic criteria. Further research with longer follow-up and more patients is necessary to confirm our findings

  1. Ultrasound Instrumentation for Beam Diagnostics and Accelerating Structures Control

    CERN Document Server

    Moiseev, V I

    2005-01-01

    Sensitive elements and electronics for ultrasound measurements at conducting walls of beam pipes and accelerating structures are described. Noise protected instrumentation provides ultrasound spectra analysis in a wide frequency range up to 5 MHz.In circular accelerators, ultrasound fields in conducting walls of beam pipe represent the space-time characteristics of circulating beams. In accelerating structures, real high power operation modes of structure can be studied by outer ultrasound monitors. The experimental results at KSRS accelerators are discussed.

  2. Formulation and acoustic studies of a new phase-shift agent for diagnostic and therapeutic ultrasound.

    Science.gov (United States)

    Sheeran, Paul S; Luois, Samantha; Dayton, Paul A; Matsunaga, Terry O

    2011-09-06

    Recent efforts in the area of acoustic droplet vaporization with the objective of designing extravascular ultrasound contrast agents has led to the development of stabilized, lipid-encapsulated nanodroplets of the highly volatile compound decafluorobutane (DFB). We developed two methods of generating DFB droplets, the first of which involves condensing DFB gas (boiling point from -1.1 to -2 °C) followed by extrusion with a lipid formulation in HEPES buffer. Acoustic droplet vaporization of micrometer-sized lipid-coated droplets at diagnostic ultrasound frequencies and mechanical indices were confirmed optically. In our second formulation methodology, we demonstrate the formulation of submicrometer-sized lipid-coated nanodroplets based upon condensation of preformed microbubbles containing DFB. The droplets are routinely in the 200-300 nm range and yield microbubbles on the order of 1-5 μm once vaporized, consistent with ideal gas law expansion predictions. The simple and effective nature of this methodology allows for the development of a variety of different formulations that can be used for imaging, drug and gene delivery, and therapy. This study is the first to our knowledge to demonstrate both a method of generating ADV agents by microbubble condensation and formulation of primarily submicrometer droplets of decafluorobutane that remain stable at physiological temperatures. Finally, activation of DFB nanodroplets is demonstrated using pressures within the FDA guidelines for diagnostic imaging, which may minimize the potential for bioeffects in humans. This methodology offers a new means of developing extravascular contrast agents for diagnostic and therapeutic applications. © 2011 American Chemical Society

  3. Does ultrasound contrast agent improve the diagnostic value of colour and power Doppler sonography in superficial lymph node enlargement?

    International Nuclear Information System (INIS)

    Schulte-Altedorneburg, Gernot; Demharter, Johannes; Linne, Renate; Droste, Dirk W.; Bohndorf, Klaus; Buecklein, Wolfgang

    2003-01-01

    Objective: to analyse whether ultrasound contrast agent (UCA) improves the diagnostic accuracy to differentiate between benign and malignant superficial lymph node enlargement by using colour-coded duplex sonography (CCDS) and power Doppler (PD). Methods: 32 patients with suspected malignant superficial lymph node enlargement prospectively underwent standardised ultrasound examinations using B-mode sonography and native and contrast-enhanced CCDS and PD immediately before biopsy. Solbiati-Index (longitudinal-transverse diameter ratio) and intranodal flow patterns by using different vascularisation types were assessed. Histological and sonographical findings were correlated. Results: 27 malignant and 5 benign lymph nodes were found. Solbiati-Index was lower in malignant lymph nodes than in benign nodes (mean 1.5 vs. 2.4, P<0.045). More intranodal flow patterns could be detected after UCA (53 vs. 43) but the number of correctly identified malignant nodes decreased after UCA (26 vs. 24) and the number of correctly identified benign nodes remained constant compared with native CCDS and PD. In 31% of the colour-mode studies, PD was considered to visualise more clearly intranodal vascular flow patterns than CCDS. Conclusion: despite depicting more intranodal vascular patterns, the use of an ultrasound contrast agent seems not to improve the diagnostic value of CCDS and PD compared with native colour-mode studies in superficial lymph node enlargement

  4. The Role of Anthropomorphic Phantoms in Diagnostic Ultrasound Imaging for Disease Characterization

    International Nuclear Information System (INIS)

    Cannon, L. M.; King, D. M.; Browne, J. E.

    2009-01-01

    An anthropomorhic phantom is an object that can mimic a region of the human anatomy. Anthropomorphic phantoms have a variety of roles in diagnostic ultrasound. These roles include quality assurance testing of ultrasound machines, calibration and testing of new imaging techniques, training of sonographers, and--most importantly--use as a tool to obtain a better understanding of disease progression in the relevant anatomy. To be anthropomorphic a phantom must accurately mimic the body in terms of its ultrasonic and mechanical properties, as well as anatomically. The acoustic properties are speed of sound, attenuation, and backscatter. The mechanical properties are elasticity and density. Phantoms are constructed from tissue-mimicking materials (TMMs). TMMs are prepared from a variety of ingredients, such as gelatine, agar, safflower oil, and glass beads. These ingredients are then boiled and cooled under controlled conditions to produce a solid TMM. To determine if the TMM has the correct acoustic properties, acoustic measurements are performed using a scanning acoustic macroscope. Mechanical measurements are also performed to test the elasticity and density properties. TMMs with the correct properties are subsequently put through a series of moulding procedures to produce the anthropomorphic phantom.

  5. Nonlinear effects in ultrasound fields of diagnostic-type transducers used for kidney stone propulsion: Characterization in water

    International Nuclear Information System (INIS)

    Karzova, M.; th Street, Seattle, WA 98105 (United States))" data-affiliation=" (Center for Industrial and Medical Ultrasound, Applied Physics Laboratory, University of Washington, 1013 NE 40th Street, Seattle, WA 98105 (United States))" >Cunitz, B.; th Street, Seattle, WA 98105 (United States))" data-affiliation=" (Center for Industrial and Medical Ultrasound, Applied Physics Laboratory, University of Washington, 1013 NE 40th Street, Seattle, WA 98105 (United States))" >Kreider, W.; th Street, Seattle, WA 98105 (United States))" data-affiliation=" (Center for Industrial and Medical Ultrasound, Applied Physics Laboratory, University of Washington, 1013 NE 40th Street, Seattle, WA 98105 (United States))" >Bailey, M.; Yuldashev, P.; Andriyakhina, Y.; th Street, Seattle, WA 98105 (United States))" data-affiliation=" (Physics Faculty, Moscow State University, Leninskie Gory, 119991 Moscow (Russian Federation); Center for Industrial and Medical Ultrasound, Applied Physics Laboratory, University of Washington, 1013 NE 40th Street, Seattle, WA 98105 (United States))" >Sapozhnikov, O.; th Street, Seattle, WA 98105 (United States))" data-affiliation=" (Physics Faculty, Moscow State University, Leninskie Gory, 119991 Moscow (Russian Federation); Center for Industrial and Medical Ultrasound, Applied Physics Laboratory, University of Washington, 1013 NE 40th Street, Seattle, WA 98105 (United States))" >Khokhlova, V.

    2015-01-01

    Newer imaging and therapeutic ultrasound technologies require higher in situ pressure levels compared to conventional diagnostic values. One example is the recently developed use of focused ultrasonic radiation force to move kidney stones and residual fragments out of the urinary collecting system. A commercial diagnostic 2.3 MHz C5-2 array probe is used to deliver the acoustic pushing pulses. The probe comprises 128 elements equally spaced at the 55 mm long convex cylindrical surface with 38 mm radius of curvature. The efficacy of the treatment can be increased by using higher intensity at the focus to provide stronger pushing force; however, nonlinear acoustic saturation can be a limiting factor. In this work nonlinear propagation effects were analyzed for the C5-2 transducer using a combined measurement and modeling approach. Simulations were based on the 3D Westervelt equation; the boundary condition was set to match the focal geometry of the beam as measured at a low power output. Focal waveforms simulated for increased output power levels were compared with the fiber-optic hydrophone measurements and were found in good agreement. It was shown that saturation effects do limit the acoustic pressure in the focal region of the transducer. This work has application to standard diagnostic probes and imaging

  6. Nonlinear effects in ultrasound fields of diagnostic-type transducers used for kidney stone propulsion: Characterization in water

    Energy Technology Data Exchange (ETDEWEB)

    Karzova, M., E-mail: masha@acs366.phys.msu.ru [Laboratoire de Mécanique des Fluides et d’Acoustique, Ecole Centrale de Lyon, 36 Avenue Guy de Collongue, 69134 Ecully (France); Physics Faculty, Moscow State University, Leninskie Gory, 119991 Moscow (Russian Federation); Cunitz, B.; Kreider, W.; Bailey, M. [Center for Industrial and Medical Ultrasound, Applied Physics Laboratory, University of Washington, 1013 NE 40" t" h Street, Seattle, WA 98105 (United States); Yuldashev, P.; Andriyakhina, Y. [Physics Faculty, Moscow State University, Leninskie Gory, 119991 Moscow (Russian Federation); Sapozhnikov, O.; Khokhlova, V. [Physics Faculty, Moscow State University, Leninskie Gory, 119991 Moscow (Russian Federation); Center for Industrial and Medical Ultrasound, Applied Physics Laboratory, University of Washington, 1013 NE 40" t" h Street, Seattle, WA 98105 (United States)

    2015-10-28

    Newer imaging and therapeutic ultrasound technologies require higher in situ pressure levels compared to conventional diagnostic values. One example is the recently developed use of focused ultrasonic radiation force to move kidney stones and residual fragments out of the urinary collecting system. A commercial diagnostic 2.3 MHz C5-2 array probe is used to deliver the acoustic pushing pulses. The probe comprises 128 elements equally spaced at the 55 mm long convex cylindrical surface with 38 mm radius of curvature. The efficacy of the treatment can be increased by using higher intensity at the focus to provide stronger pushing force; however, nonlinear acoustic saturation can be a limiting factor. In this work nonlinear propagation effects were analyzed for the C5-2 transducer using a combined measurement and modeling approach. Simulations were based on the 3D Westervelt equation; the boundary condition was set to match the focal geometry of the beam as measured at a low power output. Focal waveforms simulated for increased output power levels were compared with the fiber-optic hydrophone measurements and were found in good agreement. It was shown that saturation effects do limit the acoustic pressure in the focal region of the transducer. This work has application to standard diagnostic probes and imaging.

  7. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... top of page What are the benefits vs. risks? Benefits Most ultrasound scanning is noninvasive (no needles ... cord and hip joints in newborns and infants. Risks For standard diagnostic ultrasound , there are no known ...

  8. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... safe and accurate placement and fluid drainage for diagnosis and/or relief of patient discomfort. Doppler ultrasound ... joints in newborns and infants. Risks For standard diagnostic ultrasound , there are no known harmful effects on ...

  9. PLUS: open-source toolkit for ultrasound-guided intervention systems.

    Science.gov (United States)

    Lasso, Andras; Heffter, Tamas; Rankin, Adam; Pinter, Csaba; Ungi, Tamas; Fichtinger, Gabor

    2014-10-01

    A variety of advanced image analysis methods have been under the development for ultrasound-guided interventions. Unfortunately, the transition from an image analysis algorithm to clinical feasibility trials as part of an intervention system requires integration of many components, such as imaging and tracking devices, data processing algorithms, and visualization software. The objective of our paper is to provide a freely available open-source software platform-PLUS: Public software Library for Ultrasound-to facilitate rapid prototyping of ultrasound-guided intervention systems for translational clinical research. PLUS provides a variety of methods for interventional tool pose and ultrasound image acquisition from a wide range of tracking and imaging devices, spatial and temporal calibration, volume reconstruction, simulated image generation, and recording and live streaming of the acquired data. This paper introduces PLUS, explains its functionality and architecture, and presents typical uses and performance in ultrasound-guided intervention systems. PLUS fulfills the essential requirements for the development of ultrasound-guided intervention systems and it aspires to become a widely used translational research prototyping platform. PLUS is freely available as open source software under BSD license and can be downloaded from http://www.plustoolkit.org.

  10. Diagnostic Accuracy of Secondary Ultrasound Exam in Blunt Abdominal Trauma

    International Nuclear Information System (INIS)

    Rajabzadeh Kanafi, Alireza; Giti, Masoumeh; Gharavi, Mohammad Hossein; Alizadeh, Ahmad; Pourghorban, Ramin; Shekarchi, Babak

    2014-01-01

    In stable patients with blunt abdominal trauma, accurate diagnosis of visceral injuries is crucial. To determine whether repeating ultrasound exam will increase the sensitivity of focused abdominal sonography for trauma (FAST) through revealing additional free intraperitoneal fluid in patients with blunt abdominal trauma. We performed a prospective observational study by performing primary and secondary ultrasound exams in blunt abdominal trauma patients. All ultrasound exams were performed by four radiology residents who had the experience of more than 400 FAST exams. Five routine intraperitoneal spaces as well as the interloop space were examined by ultrasound in order to find free fluid. All patients who expired or were transferred to the operating room before the second exam were excluded from the study. All positive ultrasound results were compared with intra-operative and computed tomography (CT) findings and/or the clinical status of the patients. Primary ultrasound was performed in 372 patients; 61 of them did not undergo secondary ultrasound exam; thus, were excluded from the study.Three hundred eleven patients underwent both primary and secondary ultrasound exams. One hundred and two of all patients were evaluated by contrast enhanced CT scan and 31 underwent laparotomy. The sensitivity of ultrasound exam in detecting intraperitoneal fluid significantly increased from 70.7% for the primary exam to 92.7% for the secondary exam. Examining the interloop space significantly improved the sensitivity of ultrasonography in both primary (from 36.6% to 70.7%) and secondary (from 65.9% to 92.7%) exams. Performing a secondary ultrasound exam in stable blunt abdominal trauma patients and adding interloop space scan to the routine FAST exam significantly increases the sensitivity of ultrasound in detecting intraperitoneal free fluid

  11. Evaluation of the equine digital flexor tendon sheath using diagnostic ultrasound and contrast radiography

    International Nuclear Information System (INIS)

    Redding, W.R.

    1994-01-01

    This study was designed to evaluate the normal anatomy of the digital flexor tendon sheath using contrast radiography and diagnostic ultrasound. Iodinated contrast medium was injected into eight cadaver limbs and the limbs immediately frozen. Lateromedial and dorsopalmar/plantar radiographs were made. These limps were then cut transversely and proximal to distal radiographs of each slab were made. This cross sectional contrast methodology allowed the visualization of the relative size and shape of the superficial and deep digital flexor tendons as well as the potential space taken by effusions of the digital flexor tendon sheath. The second part of the study used twelve live animals with normal digital flexor tendon sheaths. Ultrasonographic measurement of the structures of the digital flexor tendon sheath at each level were compiled. This documented the ability of diagnostic ultrasound to image: 1) the superficial and deep digital flexor tendons, 2) the proximal and distal ring of the manica flexoria, 3) the straight and oblique sesamoidean ligaments, and 4) the mesotendinous attachments to the superficial and deep flexor tendons. Iodinated contrast medium was then injected into the digital flexor tendon sheath and the ultrasonography repeated. These images were compared with those obtained from contrast radiography and prosections of twenty normal limbs. The iodinated contrast medium enhanced sonographic imaging of the structures of the digital tendon sheath, particularly the abaxial borders of the superficial digital flexor tendon branches and the mesotendinous attachments to the superficial and deep digital flexor tendons

  12. Ultrasound-guided antegrade pyelography of renal transplants

    International Nuclear Information System (INIS)

    Wernecke, K.; Heckemann, R.; Rehwald, U.; Ringert, R.H.; Essen Univ.

    1983-01-01

    The indications for, and technique of, ultrasound-guided antegrade pyelography of renal transplants are illustrated by eight patients. Because of the detailed anatomical information which the antegrade method provides, it is superior to other diagnostic methods for the investigation of ureteric obstruction or fistulae. The severity of renal pelvis dilatation as shown by sonography must not be taken as a criterian for the grade of obstruction, since transplants may show dilated collecting systems, even in the absence of obstruction. In our view, real time sonography with a suitable probe provides the best means of achieving successful puncture of the renal pelvis. The combination of ultrasound-guided puncture and radiological contrast examination of the ureter is the best diagnostic method available and lead, in all eight cases, to immediate and definitive treatment. (orig.)

  13. Prenatal 3D Ultrasound Diagnostics in Cleidocranial Dysplasia

    DEFF Research Database (Denmark)

    Hermann, NV; Hove, HD; Jørgensen, C

    2009-01-01

    A 34-year-old Caucasian woman with cleidocranial dysplasia (CCD) and a known family history of CCD was referred for an ultrasound examination in the first trimester of her second pregnancy. Molecular genetic analysis of the RUNX2 gene was non-informative. A routine 2D ultrasound examination carried...

  14. Survey of the prevalence and methodology of quality assurance for B-mode ultrasound image quality among veterinary sonographers.

    Science.gov (United States)

    Hoscheit, Larry P; Heng, Hock Gan; Lim, Chee Kin; Weng, Hsin-Yi

    2018-05-01

    Image quality in B-mode ultrasound is important as it reflects the diagnostic accuracy and diagnostic information provided during clinical scanning. Quality assurance programs for B-mode ultrasound systems/components are comprised of initial quality acceptance testing and subsequent regularly scheduled quality control testing. The importance of quality assurance programs for B-mode ultrasound image quality using ultrasound phantoms is well documented in the human medical and medical physics literature. The purpose of this prospective, cross-sectional, survey study was to determine the prevalence and methodology of quality acceptance testing and quality control testing of image quality for ultrasound system/components among veterinary sonographers. An online electronic survey was sent to 1497 members of veterinary imaging organizations: the American College of Veterinary Radiology, the Veterinary Ultrasound Society, and the European Association of Veterinary Diagnostic Imaging, and a total of 167 responses were received. The results showed that the percentages of veterinary sonographers performing quality acceptance testing and quality control testing are 42% (64/151; 95% confidence interval 34-52%) and 26% (40/156: 95% confidence interval 19-33%) respectively. Of the respondents who claimed to have quality acceptance testing or quality control testing of image quality in place for their ultrasound system/components, 0% have performed quality acceptance testing or quality control testing correctly (quality acceptance testing 95% confidence interval: 0-6%, quality control testing 95% confidence interval: 0-11%). Further education and guidelines are recommended for veterinary sonographers in the area of quality acceptance testing and quality control testing for B-mode ultrasound equipment/components. © 2018 American College of Veterinary Radiology.

  15. Rotational multispectral fluorescence lifetime imaging and intravascular ultrasound: bimodal system for intravascular applications

    Science.gov (United States)

    Ma, Dinglong; Bec, Julien; Yankelevich, Diego R.; Gorpas, Dimitris; Fatakdawala, Hussain; Marcu, Laura

    2014-01-01

    Abstract. We report the development and validation of a hybrid intravascular diagnostic system combining multispectral fluorescence lifetime imaging (FLIm) and intravascular ultrasound (IVUS) for cardiovascular imaging applications. A prototype FLIm system based on fluorescence pulse sampling technique providing information on artery biochemical composition was integrated with a commercial IVUS system providing information on artery morphology. A customized 3-Fr bimodal catheter combining a rotational side-view fiberoptic and a 40-MHz IVUS transducer was constructed for sequential helical scanning (rotation and pullback) of tubular structures. Validation of this bimodal approach was conducted in pig heart coronary arteries. Spatial resolution, fluorescence detection efficiency, pulse broadening effect, and lifetime measurement variability of the FLIm system were systematically evaluated. Current results show that this system is capable of temporarily resolving the fluorescence emission simultaneously in multiple spectral channels in a single pullback sequence. Accurate measurements of fluorescence decay characteristics from arterial segments can be obtained rapidly (e.g., 20 mm in 5 s), and accurate co-registration of fluorescence and ultrasound features can be achieved. The current finding demonstrates the compatibility of FLIm instrumentation with in vivo clinical investigations and its potential to complement conventional IVUS during catheterization procedures. PMID:24898604

  16. Image processing in medical ultrasound

    DEFF Research Database (Denmark)

    Hemmsen, Martin Christian

    This Ph.D project addresses image processing in medical ultrasound and seeks to achieve two major scientific goals: First to develop an understanding of the most significant factors influencing image quality in medical ultrasound, and secondly to use this knowledge to develop image processing...... multiple imaging setups. This makes the system well suited for development of new processing methods and for clinical evaluations, where acquisition of the exact same scan location for multiple methods is important. The second project addressed implementation, development and evaluation of SASB using...... methods for enhancing the diagnostic value of medical ultrasound. The project is an industrial Ph.D project co-sponsored by BK Medical ApS., with the commercial goal to improve the image quality of BK Medicals scanners. Currently BK Medical employ a simple conventional delay-and-sum beamformer to generate...

  17. Ultrasound findings in biliary system

    International Nuclear Information System (INIS)

    Park, Won Sik; Lee, Yong Woo; Cheung, Hwan

    1986-01-01

    In the liver and biliary system ultrasound has emerged as one of the most useful imaging techniques. It is usually the first radiological procedure selected and is often sufficient alone to enable a clinical decision to be made. Good result with ultrasound depend critically on expert scanning technique coupled with an understanding of tomographic anatomy and, of course, an appreciation of the clinical significance of any findings. In addition to we'd like to stress on the ultrasonical anatomy and for the technologist and also discuss about pathological part

  18. Ultrasound imaging

    International Nuclear Information System (INIS)

    Wells, P.N.T.

    1983-01-01

    Ultrasound is a form of energy which consists of mechanical vibrations the frequencies of which are so high that they are above the range of human hearing. The lower frequency limit of the ultrasonic spectrum may generally be taken to be about 20 kHz. Most biomedical applications of ultrasound employ frequencies in the range 1-15 MHz. At these frequencies, the wavelength is in the range 1.5 - 0.1 mm in soft tissues, and narrow beams of ultrasound can be generated which propagate through such tissues without excessive attenuation. This chapter begins with brief reviews of the physics of diagnostic ultrasound pulse-echo imaging methods and Doppler imaging methods. The remainder of the chapter is a resume of the applications of ultrasonic imaging to physiological measurement

  19. The Interobserver Variability and Diagnostic Performance of 3-Dimensional Breast Ultrasound

    International Nuclear Information System (INIS)

    Lyou, Chae Yeon; Kim, Sun Mi; Jang, Mi Jung; Kim, Sung Won; Kang, Eun Young; Park, So Yeon; Moon, Woo Kyung

    2011-01-01

    We wanted to evaluate the interobserver variability and diagnostic performance of 3-dimensional (3D) breast ultrasound (US) as compared with that of 2- dimensional (2D) US. We included 150 patients who received US-guided core biopsy and 3D US between June 2009 and April 2010. Three breast imaging radiologists analyzed the 2D and 3D US images using the Breast Imaging Reporting and Data System (BI-RADS) lexicon. The intra-observer agreement and inter-observer agreement were calculated. The sensitivity and specificity of 2D and 3D US were evaluated. The intra-observer agreement between 2D and 3D US was mostly slight or fair agreement. However, in terms of the final category, there was substantial agreement for all three radiologists. The inter-observer agreement of 3D US was similar to that of 2D US (moderate agreement for shape, orientation, circumscribed margin and boundary: fair agreement for indistinct margin, angular margin, microlobulated margin, echo pattern and final category). The sensitivity of 3D US for breast cancer was higher than that of 2D US for two radiologists (2D vs. 3D for reader 2: 55.8% vs. 61.5%, 2D vs. 3D for reader 3: 59.6% vs. 63.5%), and the specificity of 3D US was lower than that of 2D US for all the readers (2D vs. 3D for reader 1: 90.8% vs. 86.7%, 2D vs. 3D for reader 2: 90.8% vs. 87.8%, 2D vs. 3D for reader 3: 94.9% vs. 90.8%), but the difference was not significant (p ≥ 0.05). The interobserver variability and diagnostic performance of 3D breast US were similar to those of 2D US

  20. Systematic evaluation of a secondary method for measuring diagnostic-level medical ultrasound transducer output power based on a large-area pyroelectric sensor

    Science.gov (United States)

    Zeqiri, B.; Žauhar, G.; Rajagopal, S.; Pounder, A.

    2012-06-01

    measurement, appropriate for clinical diagnostic ultrasound systems, are discussed.

  1. The Role of Anthropomorphic Phantoms in Diagnostic Ultrasound Imaging for Disease Characterization (abstract)

    Science.gov (United States)

    Cannon, L. M.; King, D. M.; Browne, J. E.

    2009-04-01

    An anthropomorhic phantom is an object that can mimic a region of the human anatomy. Anthropomorphic phantoms have a variety of roles in diagnostic ultrasound. These roles include quality assurance testing of ultrasound machines, calibration and testing of new imaging techniques, training of sonographers, and-most importantly-use as a tool to obtain a better understanding of disease progression in the relevant anatomy. To be anthropomorphic a phantom must accurately mimic the body in terms of its ultrasonic and mechanical properties, as well as anatomically. The acoustic properties are speed of sound, attenuation, and backscatter. The mechanical properties are elasticity and density. Phantoms are constructed from tissue-mimicking materials (TMMs). TMMs are prepared from a variety of ingredients, such as gelatine, agar, safflower oil, and glass beads. These ingredients are then boiled and cooled under controlled conditions to produce a solid TMM. To determine if the TMM has the correct acoustic properties, acoustic measurements are performed using a scanning acoustic macroscope. Mechanical measurements are also performed to test the elasticity and density properties. TMMs with the correct properties are subsequently put through a series of moulding procedures to produce the anthropomorphic phantom.

  2. Outcomes of ultrasound guided renal mass biopsies.

    Science.gov (United States)

    Sutherland, Edward L; Choromanska, Agnieszka; Al-Katib, Sayf; Coffey, Mary

    2018-06-01

    The purpose of this study was to evaluate the rate of nondiagnostic ultrasound-guided renal mass biopsies (RMBs) at our institution and to determine what patient, procedural, and focal renal mass (FRM) factors were associated with nondiagnostic ultrasound-guided RMBs. Eighty-two ultrasound-guided renal mass biopsies performed between January 2014 and October 2016 were included in our study. Biopsy outcomes (diagnostic vs. nondiagnostic) and patient, procedural, and FRM characteristics were retrospectively reviewed and recorded. Univariate statistical analyses were performed to identify biopsy characteristics that were indicative of nondiagnostic biopsy. Ultrasound-guided RMBs were diagnostic in 70 out of 82 cases (85%) and non-diagnostic in 12 cases (15%). Among the diagnostic biopsies, 54 (77%) were malignant cases, 94% of which were renal cell carcinoma (RCC). Of the 12 nondiagnostic cases, the final diagnosis was RCC in 4 cases and angiomyolipoma in one case; seven of the nondiagnostic cases were lost to follow-up. A weak association (p = 0.04) was found between the number of needle passes and the biopsy outcome. None of the remaining collected RMB characteristics showed a significant correlation with a diagnostic or nondiagnostic RMB. Six patients (7%) experienced complications. Ultrasound-guided renal mass biopsy is a safe and effective method for the diagnosis of renal masses with a low rate of nondiagnostic outcomes. A nondiagnostic biopsy should not be treated as a surrogate for a diagnosis since a significant number of patients with nondiagnostic biopsies have subsequently been shown to have renal malignancies. Repeat biopsy should be considered in such cases.

  3. Droplets, Bubbles and Ultrasound Interactions

    NARCIS (Netherlands)

    Shpak, O.; Verweij, M.; de Jong, N.; Versluis, Michel; Escoffre, J.M.; Bouakaz, A.

    2016-01-01

    The interaction of droplets and bubbles with ultrasound has been studied extensively in the last 25 years. Microbubbles are broadly used in diagnostic and therapeutic medical applications, for instance, as ultrasound contrast agents. They have a similar size as red blood cells, and thus are able to

  4. Diagnostic accuracy of ultrasound, computed tomography, and endoscopic retrograde choleangiopancreatography in the detection of obstructive jaundice

    International Nuclear Information System (INIS)

    Pasanen, P.A.; Partainen, K.; Pikkarainen, P.; Alhava, E.; Pirinen, A.; Janatuinen, E.

    1991-01-01

    The purpose of this prospective study was to investigate the diagnostic accuracy of ultrasound (US), computed tomography (CT), and endoscopic retrograde cholangiopancreatography (ERCP) in the distinction between extrahepatic and intrahepatic causes of jaundice. The limit for the inclusion to the study was defined as a serum bilirubin concentration ≥40μmol/l. Altogether 187 jaundiced patients were studied. The sensitivities of US, CT and ERCP were 63%, 77%, and 87%, respectively. The differences between all these methods were statistically significant. The specificities and positive predictive values were high, reaching 96-99%, but the negative predictive values were low, ranging between 38% and 60%. Choledochal stone disease constituted the main etiology of false-negative studies in all investigations. Imaging procedures have a prominent role in the diagnostic study of the jaundiced patient, but it is obvious that their diagnostic accuracy may vary between institutions because of the variance in local experience and expertise and because of the differences in diseases causing jaundice. 37 refs., 5 tabs

  5. Robot-assisted ultrasound imaging: overview and development of a parallel telerobotic system.

    Science.gov (United States)

    Monfaredi, Reza; Wilson, Emmanuel; Azizi Koutenaei, Bamshad; Labrecque, Brendan; Leroy, Kristen; Goldie, James; Louis, Eric; Swerdlow, Daniel; Cleary, Kevin

    2015-02-01

    Ultrasound imaging is frequently used in medicine. The quality of ultrasound images is often dependent on the skill of the sonographer. Several researchers have proposed robotic systems to aid in ultrasound image acquisition. In this paper we first provide a short overview of robot-assisted ultrasound imaging (US). We categorize robot-assisted US imaging systems into three approaches: autonomous US imaging, teleoperated US imaging, and human-robot cooperation. For each approach several systems are introduced and briefly discussed. We then describe a compact six degree of freedom parallel mechanism telerobotic system for ultrasound imaging developed by our research team. The long-term goal of this work is to enable remote ultrasound scanning through teleoperation. This parallel mechanism allows for both translation and rotation of an ultrasound probe mounted on the top plate along with force control. Our experimental results confirmed good mechanical system performance with a positioning error of < 1 mm. Phantom experiments by a radiologist showed promising results with good image quality.

  6. Physics of Ultrasound. Chapter 12

    Energy Technology Data Exchange (ETDEWEB)

    Lacefield, J. C. [University of Western Ontario, London (Canada)

    2014-09-15

    Ultrasound is the most commonly used diagnostic imaging modality, accounting for approximately 25% of all imaging examinations performed worldwide at the beginning of the 21st century. The success of ultrasound may be attributed to a number of attractive characteristics, including the relatively low cost and portability of an ultrasound scanner, the non-ionizing nature of ultrasound waves, the ability to produce real time images of blood flow and moving structures such as the beating heart, and the intrinsic contrast among soft tissue structures that is achieved without the need for an injected contrast agent. The latter characteristic enables ultrasound to be used for a wide range of medical applications, which historically have primarily included cardiac and vascular imaging, imaging of the abdominal organs and, most famously, in utero imaging of the developing fetus. Ongoing technological improvements continue to expand the use of ultrasound for many applications, including cancer imaging, musculoskeletal imaging, ophthalmology and others. The term ultrasound refers specifically to acoustic waves at frequencies greater than the maximum frequency audible to humans, which is nominally 20 kHz. Diagnostic imaging is generally performed using ultrasound in the frequency range of 2–15 MHz. The choice of frequency is dictated by a trade off between spatial resolution and penetration depth, since higher frequency waves can be focused more tightly but are attenuated more rapidly by tissue. The information contained in an ultrasonic image is influenced by the physical processes underlying propagation, reflection and attenuation of ultrasound waves in tissue.

  7. Computer-Aided Diagnosis of Different Rotator Cuff Lesions Using Shoulder Musculoskeletal Ultrasound.

    Science.gov (United States)

    Chang, Ruey-Feng; Lee, Chung-Chien; Lo, Chung-Ming

    2016-09-01

    The lifetime prevalence of shoulder pain approaches 70%, which is mostly attributable to rotator cuff lesions such as inflammation, calcific tendinitis and tears. On clinical examination, shoulder ultrasound is recommended for the detection of lesions. However, there exists inter-operator variability in diagnostic accuracy because of differences in the experience and expertise of operators. In this study, a computer-aided diagnosis (CAD) system was developed to assist ultrasound operators in diagnosing rotator cuff lesions and to improve the practicality of ultrasound examination. The collected cases included 43 cases of inflammation, 30 cases of calcific tendinitis and 26 tears. For each case, the lesion area and texture features were extracted from the entire lesions and combined in a multinomial logistic regression classifier for lesion classification. The proposed CAD achieved an accuracy of 87.9%. The individual accuracy of this CAD system was 88.4% for inflammation, 83.3% for calcific tendinitis and 92.3% for tears. Cohen's k was 0.798. On the basis of its diagnostic performance, clinical use of this CAD technique has promise. Copyright © 2016 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  8. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... of the reflected sound waves (called the Doppler effect). A computer collects and processes the sounds and ... standard diagnostic ultrasound , there are no known harmful effects on humans. top of page What are the ...

  9. Prostate Ultrasound

    Medline Plus

    Full Text Available ... needle biopsies and fluid aspiration. Risks For standard diagnostic ultrasound , there are no known harmful effects on ... and Resources RTAnswers.org Radiation Therapy for Prostate Cancer top of page This page was reviewed on ...

  10. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... sexes without x-ray exposure. Risks For standard diagnostic ultrasound , there are no known harmful effects on ... and Resources RTAnswers.org Radiation Therapy for Gynecologic Cancers Radiation Therapy for Prostate Cancer top of page ...

  11. Prostate Ultrasound

    Medline Plus

    Full Text Available ... the rectal wall is relatively insensitive to the pain in the region of the prostate. A biopsy ... needle biopsies and fluid aspiration. Risks For standard diagnostic ultrasound , there are no known harmful effects on ...

  12. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... tip of the transducer is smaller than the standard speculum used when performing a Pap test . A ... both sexes without x-ray exposure. Risks For standard diagnostic ultrasound , there are no known harmful effects ...

  13. Diagnostic utility of three-dimensional power Doppler ultrasound for postmenopausal bleeding.

    Science.gov (United States)

    Kim, Ari; Lee, Ji Young; Chun, Sungwook; Kim, Heung Yeol

    2015-06-01

    We evaluated the role of three-dimensional power Doppler ultrasound (3D PD-US) to detect endometrial lesions in women with postmenopausal endometrial bleeding. In this prospective observational study, from January 2009 to November 2012, we recruited 225 postmenopausal women with postmenopausal uterine bleeding who met the study criteria. Women who had hematologic disease, chronic medical diseases, or nonuterine pelvic diseases were excluded. Prior to endometrial biopsy, the patients underwent a baseline transvaginal ultrasound screening. The vascular indices and endometrial volumes were calculated with 3D PD-US and compared with the endometrial histopathology. Among the endometrial histopathologic findings of 174 women, atrophic endometrium was the most common finding (30.5%). Endometrial malignancy was confirmed in 28 cases (16.1%), and endometrial hyperplasia was diagnosed in 17 cases (9.8%). The prevalence of endometrial cancer was high in patients who had endometrial thickness >9.5 mm (p < 0.001) and volume greater than 4.05 mL (p < 0.001). For the endometrial carcinoma only, the cutoff values of vascular index, flow index, and vascular flow index for predicting malignancy were 13.070, 12.610, and 3.764, respectively. For endometrial hyperplasia, endometrial thickness and vascular flow index were significant findings. Endometrial vasculature and volume can be obtained using 3D PD-US. The diagnostic usefulness of 3D PD-US for endometrial diseases is promising in women with postmenopausal endometrial bleeding. Copyright © 2015. Published by Elsevier B.V.

  14. A thermal technique for local ultrasound intensity measurement: part 2. Application to exposimetry on a medical diagnostic device

    International Nuclear Information System (INIS)

    Wilkens, V

    2010-01-01

    Acoustic output measurements on medical ultrasound equipment are usually performed using radiation force balances to determine the output power and using hydrophones to determine pressure and intensity parameters. The local temporal-average ultrasound intensity can be measured alternatively by thermal sensors. The technique was described and prototype sensors were characterized in a preceding paper. Here, the application of such a thermal intensity sensor to the output beam characterization of a typical medical diagnostic device is described. Two transducers, a 7.5 MHz linear array and a 3.5 MHz convex array were investigated in different operating modes. For comparison, hydrophone measurements were also performed. If the spatial averaging effect is taken into account, good agreement is found between both measurement methods. The maximum deviations of the spatial-peak temporal-average intensities I SPTA obtained with the thermal sensor from the corresponding hydrophone-based results were below 12%. The simple thermal technique offers advantages for intensity measurements especially in the case of scanning and combined modes of the diagnostic device, where the synchronization between hydrophone measurements and the complex pulse emission pattern can be difficult

  15. Open-access ultrasound referrals from general practice.

    LENUS (Irish Health Repository)

    Hughes, P

    2015-03-01

    Direct access referral for radiological investigations from General Practice (GP) provides an indispensable diagnostic tool and avoids the inherently long waiting time that referral through a hospital based specialty would entail. Improving access to hospital based radiology services is one of Health Information and Quality Authority\\'s key recommendations in its report on patient referrals from general practice. This study aimed to review all GP referrals for ultrasound investigations to a tertiary referral teaching hospital over a seven month period with respect to their demographics, waiting times and diagnostic outcomes. 1,090 ultrasounds originating in general practice were carried out during the study period. Positive findings were recorded in 332 (30.46%) examinations. The median waiting time from receipt of referral to the diagnostic investigation was 56 days (range 16 - 91 years). 71 (6.5%) patients had follow-up imaging investigations while recommendation for hospital based specialty referral was made in 35 cases (3.2%). Significant findings included abdominal aortic aneurysms, metastatic disease and lymphoma. Direct access to ultrasound for general practitioners allows the referring physician to make an informed decision with regard to the need for specialist referral. We believe these findings help support the case for national direct access to diagnostic ultrasound for general practitioners.

  16. Diagnostic accuracy of contrast-enhanced ultrasound for the differential diagnosis of hepatocellular carcinoma: ESCULAP versus CEUS-LI-RADS.

    Science.gov (United States)

    Schellhaas, Barbara; Görtz, Ruediger S; Pfeifer, Lukas; Kielisch, Christian; Neurath, Markus F; Strobel, Deike

    2017-09-01

    A comparison is made of two contrast-enhanced ultrasound (CEUS) algorithms for the diagnosis of hepatocellular carcinoma (HCC) in high-risk patients: Erlanger Synopsis of Contrast-enhanced Ultrasound for Liver lesion Assessment in Patients at Risk (ESCULAP) and American College of Radiology Contrast-Enhanced Ultrasound-Liver Imaging Reporting and Data System (ACR-CEUS-LI-RADSv.2016). Focal liver lesions in 100 high-risk patients were assessed using both CEUS algorithms (ESCULAP and CEUS-LI-RADSv.2016) for a direct comparison. Lesions were categorized according to size and contrast enhancement in the arterial, portal venous and late phases.For the definite diagnosis of HCC, categories ESCULAP-4, ESCULAP-Tr and ESCULAP-V and CEUS-LI-RADS-LR-5, LR-Tr and LR-5-V were compared. In addition, CEUS-LI-RADS-category LR-M (definitely/probably malignant, but not specific for HCC) and ESCULAP-category C [intrahepatic cholangiocellular carcinoma (ICC)] were compared.Histology, CE-computed tomography and CE-MRI served as reference standards. The reference standard among 100 lesions included 87 HCCs, six ICCs and seven non-HCC-non-ICC-lesions. For the diagnosis of HCC, the diagnostic accuracy of CEUS was significantly higher with ESCULAP versus CEUS-LI-RADS (94.3%/72.4%; pdiagnostic accuracy for ICC (LR-M/ESCULAP-C) was identical with both algorithms (50%), with higher PPV for ESCULAP-C versus LR-M (75 vs. 50%). CEUS-based algorithms contribute toward standardized assessment and reporting of HCC-suspect lesions in high-risk patients. ESCULAP shows significantly higher diagnostic accuracy, sensitivity and negative predictive value with no loss of specificity compared with CEUS-LI-RADS. Both algorithms have an excellent PPV. Arterial hyperenhancement is the key feature for the diagnosis of HCC with CEUS. Washout should not be a necessary prerequisite for the diagnosis of definite HCC. CEUS-LI-RADS in its current version is inferior to ESCULAP for the noninvasive diagnosis of HCC

  17. Active ultrasound pattern injection system (AUSPIS for interventional tool guidance.

    Directory of Open Access Journals (Sweden)

    Xiaoyu Guo

    Full Text Available Accurate tool tracking is a crucial task that directly affects the safety and effectiveness of many interventional medical procedures. Compared to CT and MRI, ultrasound-based tool tracking has many advantages, including low cost, safety, mobility and ease of use. However, surgical tools are poorly visualized in conventional ultrasound images, thus preventing effective tool tracking and guidance. Existing tracking methods have not yet provided a solution that effectively solves the tool visualization and mid-plane localization accuracy problem and fully meets the clinical requirements. In this paper, we present an active ultrasound tracking and guiding system for interventional tools. The main principle of this system is to establish a bi-directional ultrasound communication between the interventional tool and US imaging machine within the tissue. This method enables the interventional tool to generate an active ultrasound field over the original imaging ultrasound signals. By controlling the timing and amplitude of the active ultrasound field, a virtual pattern can be directly injected into the US machine B mode display. In this work, we introduce the time and frequency modulation, mid-plane detection, and arbitrary pattern injection methods. The implementation of these methods further improves the target visualization and guiding accuracy, and expands the system application beyond simple tool tracking. We performed ex vitro and in vivo experiments, showing significant improvements of tool visualization and accurate localization using different US imaging platforms. An ultrasound image mid-plane detection accuracy of ±0.3 mm and a detectable tissue depth over 8.5 cm was achieved in the experiment. The system performance is tested under different configurations and system parameters. We also report the first experiment of arbitrary pattern injection to the B mode image and its application in accurate tool tracking.

  18. The effect of nonlinear propagation on heating of tissue: A numerical model of diagnostic ultrasound beams

    Science.gov (United States)

    Cahill, Mark D.; Humphrey, Victor F.; Doody, Claire

    2000-07-01

    Thermal safety indices for diagnostic ultrasound beams are calculated under the assumption that the sound propagates under linear conditions. A non-axisymmetric finite difference model is used to solve the KZK equation, and so to model the beam of a diagnostic scanner in pulsed Doppler mode. Beams from both a uniform focused rectangular source and a linear array are considered. Calculations are performed in water, and in attenuating media with tissue-like characteristics. Attenuating media are found to exhibit significant nonlinear effects for finite-amplitude beams. The resulting loss of intensity by the beam is then used as the source term in a model of tissue heating to estimate the maximum temperature rises. These are compared with the thermal indices, derived from the properties of the water-propagated beams.

  19. High-frequency ultrasound imaging of tattoo reactions with histopathology as a comparative method. Introduction of preoperative ultrasound diagnostics as a guide to therapeutic intervention.

    Science.gov (United States)

    Carlsen, K Hutton; Tolstrup, J; Serup, J

    2014-08-01

    Tattoo adverse reactions requiring diagnostic evaluation and treatment are becoming more common. The aim of this study was to assess tattoo reactions by 20-MHz ultrasonography referenced to histopathology as a comparative method. A total of 73 individuals with clinical adverse reactions in their tattoos were studied. Punch biopsies for reference histology were available from 58 patients. The Dermascan C(®) of Cortex Technology, Denmark, was employed. Total skin thickness and echo density of the echolucent band in the outer dermis were measured. Biopsy served for diagnosis and for determination of the level of cellular infiltration in the dermis. In every tattoo reaction studied, the skin affected was found thicker compared with regional control of the same individual (mean difference 0.73 mm). A prominent echolucent band of mean thickness 0.89 mm was demonstrated, primarily located in the very outer dermis but propagating to deeper dermal layers parallel to increasing severity of reactions. The thickness of the echolucent band correlated with the thickness of cellular infiltration determined by microscopic examination, R = 0.6412 (P tattoo reactions showed no distinct characteristics by ultrasound, but mainly displayed themselves by their advanced inflammatory component. It is demonstrated for the first time that ultrasound, with histopathology as the comparative method, can quantify the severity of tattoo reactions and non-invasively diagnose the depth of the inflammatory process in the dermis elicited by the microparticulate tattoo pigment, which itself is too minute to be imaged by ultrasound. Preoperative 20-MHz ultrasound scanning is introduced as a potentially useful method to guide therapeutic interventions by surgery and lasers. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  20. Diagnostic possibilities of ultrasound examination and diuretic nephrography (Furosemide test F +20) to evaluate hydronephrosis in children

    International Nuclear Information System (INIS)

    Boueva, A.; Palashev, J.; Mlachkov, N.

    2005-01-01

    The aim of this study is to compare diagnostic value of kidney ultrasound examination (US) and diuretic nephrography (furosemide test F+20) for assessment of the kind and degree of obstructive renal changes in childhood. 12 children (8 girls and 4 boys; mean age 4.4 years) with observation of congenital hydronephrosis were examined. Diuretic 99mTc-EC nephrography (F+20) with SPECT gamma camera STARCAM 40001 (General Electric) was done. The results of 99mTc-EC Diuretic nephrography (F+20) were as follows: positive furosemide test (F+20) in ten children (seven girls and tree boys) 83.3% and no found dynamic changes in drainage after (F+20) in 2 children (one girl and one boy) 16.7%. Correlation between ultrasound examination and Diuretic nephrography 99mTcEC (F+20) for the diagnosis hydronephrosis was 100 %. The ultrasound examination and 99mTc-EC Diuretic nephrography (F+20) are highly informative and suitable methods for assessment kind and degree of hydronephrosis in children. The combination of two methods allows a possibility of differentiation of the type of obstruction - functional or organic etiology

  1. A single FPGA-based portable ultrasound imaging system for point-of-care applications.

    Science.gov (United States)

    Kim, Gi-Duck; Yoon, Changhan; Kye, Sang-Bum; Lee, Youngbae; Kang, Jeeun; Yoo, Yangmo; Song, Tai-kyong

    2012-07-01

    We present a cost-effective portable ultrasound system based on a single field-programmable gate array (FPGA) for point-of-care applications. In the portable ultrasound system developed, all the ultrasound signal and image processing modules, including an effective 32-channel receive beamformer with pseudo-dynamic focusing, are embedded in an FPGA chip. For overall system control, a mobile processor running Linux at 667 MHz is used. The scan-converted ultrasound image data from the FPGA are directly transferred to the system controller via external direct memory access without a video processing unit. The potable ultrasound system developed can provide real-time B-mode imaging with a maximum frame rate of 30, and it has a battery life of approximately 1.5 h. These results indicate that the single FPGA-based portable ultrasound system developed is able to meet the processing requirements in medical ultrasound imaging while providing improved flexibility for adapting to emerging POC applications.

  2. [Ultrasound diagnosis of aneurysm of the vein of Galen in children].

    Science.gov (United States)

    Gazikalović, S; Kosutić, J; Komar, P; Vukomanović, V; Mogić, M

    2001-01-01

    Aneurysm of the vein of Galen is rare and complex vascular disorder that develops during embriogenesis and provokes significant haemodynamic changes. Boys are more frequently involved. During the foetal period Ballantyne syndrome may develop, and postnatal clinical presentation vary with ages. Serious haemodynamic changes are followed by congestive heart failure and, if not treated, with lethal exitus. Fast and correct diagnosis is very important. Ultrasound examination of central nervous system supported with Duplex-Doppler and Colour-Doppler examination of the head and heart enables the diagnosis. This text comments ultrasound presentation of the malformation and ultrasound diagnostic possibilities.

  3. Acute diverticulitis of the sigmoid colon: value of ultrasound as an initial diagnostic test; Diverticulitis aguad de sigma: valor de la ecografia como test diagnostico inicial

    Energy Technology Data Exchange (ETDEWEB)

    Garcia-Aguayo, F J; Gil, P M [Hospital de Sagunto. Valencia (Spain)

    2002-07-01

    To assess the value of ultrasound as an initial diagnostic method in cases of acute diverticulitis. Ultrasound was carried out in 76 patients with a clinical diagnosis of acute sigmoid diverticulitis. The final diagnosis was based on the clinical course in every case, as well as on computed tomography (CT; n=46), histopathological examination (n=10), colonoscopy (n=4) and barium enema (n=2). The diagnostic criteria established for ultrasound was a thickening of the sigmoid colon wall of >4 mm and the presence of a least one of the following features: diverticular, phlegmon or abscess. The CT diagnosis was based on two indispensable findings: thickening of the sigmoid colon of>4 mm and inflammation of pericolonic fat. The final diagnosis was acute diverticulitis in 52 patients, some other disease in 18 and undetermined in 6. The sensitivities of ultrasound and CT were 81% and 94%, respectively, and their specificities were 79% and 83%, respectively. Of the 10 false negatives on ultrasound, seven corresponded to cases of simple diverticulitis and three to cases of complicated diverticulitis (two in patients with abscess and one in a patient with pneumoperitoneum). CT provided the correct diagnosis in eight of these cases, and resulted in false negatives in two cases of mild diverticulitis. Ultrasound is a valid test in the initial diagnosis of acute diverticulitis of the sigmoid colon. CT should be performed when ultrasound fails to provide a diagnosis or in cases of negative results when there is a strong clinical suspicion of diverticulitis, as well as when the possibility of complicated diverticulitis exists. (Author) 14 refs.

  4. Diagnostic sensitivity of ultrasound, radiography and computed tomography for gender determination in four species of lizards.

    Science.gov (United States)

    Di Ianni, Francesco; Volta, Antonella; Pelizzone, Igor; Manfredi, Sabrina; Gnudi, Giacomo; Parmigiani, Enrico

    2015-01-01

    Gender determination is frequently requested by reptile breeders, especially for species with poor or absent sexual dimorphism. The aims of the current study were to describe techniques and diagnostic sensitivities of ultrasound, radiography, and computed tomography for gender determination (identification of hemipenes) in four species of lizards. Nineteen lizards of known sex, belonging to four different species (Pogona vitticeps, Uromastyx aegyptia, Tiliqua scincoides, Gerrhosaurus major) were prospectively enrolled. With informed owner consent, ultrasound, noncontrast CT, contrast radiography, and contrast CT (with contrast medium administered into the cloaca) were performed in conscious animals. Imaging studies were reviewed by three different operators, each unaware of the gender of the animals and of the results of the other techniques. The lizard was classified as a male when hemipenes were identified. Nineteen lizards were included in the study, 10 females and nine males. The hemipenes were seen on ultrasound in only two male lizards, and appeared as oval hypoechoic structures. Radiographically, hemipenes filled with contrast medium appeared as spindle-shaped opacities. Noncontrast CT identified hemipenes in only two lizards, and these appeared as spindle-shaped kinked structures with hyperattenuating content consistent with smegma. Hemipenes were correctly identified in all nine males using contrast CT (accuracy of 100%). Accuracy of contrast radiography was excellent (94.7%). Accuracy of ultrasound and of noncontrast CT was poor (64.3% and 63.1%, respectively). Findings from the current study supported the use of contrast CT or contrast radiography for gender determination in lizards. © 2014 American College of Veterinary Radiology.

  5. EFSUMB Guidelines on Interventional Ultrasound (INVUS), Part IV - EUS-guided interventions

    DEFF Research Database (Denmark)

    Jenssen, C; Hocke, M; Fusaroli, P

    2016-01-01

    The fourth part of the European Federation of Societies for Ultrasound in Medicine and Biology (EFSUMB) Guidelines on Interventional Ultrasound describes general aspects of endoscopic ultrasound-guided diagnostic and therapeutic interventions and assesses the evidence for endoscopic ultrasound-gu...

  6. Implementing an ultrasound-based protocol for diagnosingappendicitis while maintaining diagnostic accuracy

    International Nuclear Information System (INIS)

    Van Atta, Angela J.; Baskin, Henry J.; Maves, Connie K.; Dansie, David M.; Rollins, Michael D.; Bolte, Robert G.; Mundorff, Michael B.; Andrews, Seth P.

    2015-01-01

    The use of ultrasound to diagnose appendicitis in children is well-documented but not universally employed outside of pediatric academic centers, especially in the United States. Various obstacles make it difficult for institutions and radiologists to abandon a successful and accurate CT-based imaging protocol in favor of a US-based protocol. To describe how we overcame barriers to implementing a US-based appendicitis protocol among a large group of nonacademic private-practice pediatric radiologists while maintaining diagnostic accuracy and decreasing medical costs. A multidisciplinary team of physicians (pediatric surgery, pediatric emergency medicine and pediatric radiology) approved an imaging protocol using US as the primary modality to evaluate suspected appendicitis with CT for equivocal cases. The protocol addressed potential bias against US and accommodated for institutional limitations of radiologist and sonographer experience and availability. Radiologists coded US reports according to the probability of appendicitis. Radiology reports were compared with clinical outcomes to assess diagnostic accuracy. During the study period, physicians from each group were apprised of the interim US protocol accuracy results. Problematic cases were discussed openly. A total of 512 children were enrolled and underwent US for evaluation of appendicitis over a 30-month period. Diagnostic accuracy was comparable to published results for combined US/CT protocols. Comparing the first 12 months to the last 12 months of the study period, the proportion of children achieving an unequivocal US result increased from 30% (51/169) to 53% (149/282) and the proportion of children undergoing surgery based solely on US findings increased from 55% (23/42) to 84% (92/109). Overall, 63% (325/512) of patients in the protocol did not require a CT. Total patient costs were reduced by $30,182 annually. We overcame several barriers to implementing a US protocol. During the study period our

  7. Implementing an ultrasound-based protocol for diagnosingappendicitis while maintaining diagnostic accuracy

    Energy Technology Data Exchange (ETDEWEB)

    Van Atta, Angela J. [University of Utah School of Medicine, Salt Lake City, UT (United States); Baskin, Henry J.; Maves, Connie K.; Dansie, David M. [Primary Children' s Hospital, Department of Radiology, Salt Lake City, UT (United States); Rollins, Michael D. [University of Utah School of Medicine, Department of Surgery, Division of Pediatric Surgery, Salt Lake City, UT (United States); Bolte, Robert G. [University of Utah School of Medicine, Department of Pediatrics, Division of Pediatric Emergency Medicine, Salt Lake City, UT (United States); Mundorff, Michael B.; Andrews, Seth P. [Primary Children' s Hospital, Systems Improvement, Salt Lake City, UT (United States)

    2015-05-01

    The use of ultrasound to diagnose appendicitis in children is well-documented but not universally employed outside of pediatric academic centers, especially in the United States. Various obstacles make it difficult for institutions and radiologists to abandon a successful and accurate CT-based imaging protocol in favor of a US-based protocol. To describe how we overcame barriers to implementing a US-based appendicitis protocol among a large group of nonacademic private-practice pediatric radiologists while maintaining diagnostic accuracy and decreasing medical costs. A multidisciplinary team of physicians (pediatric surgery, pediatric emergency medicine and pediatric radiology) approved an imaging protocol using US as the primary modality to evaluate suspected appendicitis with CT for equivocal cases. The protocol addressed potential bias against US and accommodated for institutional limitations of radiologist and sonographer experience and availability. Radiologists coded US reports according to the probability of appendicitis. Radiology reports were compared with clinical outcomes to assess diagnostic accuracy. During the study period, physicians from each group were apprised of the interim US protocol accuracy results. Problematic cases were discussed openly. A total of 512 children were enrolled and underwent US for evaluation of appendicitis over a 30-month period. Diagnostic accuracy was comparable to published results for combined US/CT protocols. Comparing the first 12 months to the last 12 months of the study period, the proportion of children achieving an unequivocal US result increased from 30% (51/169) to 53% (149/282) and the proportion of children undergoing surgery based solely on US findings increased from 55% (23/42) to 84% (92/109). Overall, 63% (325/512) of patients in the protocol did not require a CT. Total patient costs were reduced by $30,182 annually. We overcame several barriers to implementing a US protocol. During the study period our

  8. Modification of Food Systems by Ultrasound

    Directory of Open Access Journals (Sweden)

    L. M. Carrillo-Lopez

    2017-01-01

    Full Text Available This review describes the mechanism, operation, and recent potential applications of ultrasound in various food systems, as well as the physical and chemical effects of ultrasound treatments on the conservation and modification of different groups of food. Acoustic energy has been recognized as an emerging technology with great potential for applications in the food industry. The phenomenon of acoustic cavitation, which modifies the physical, chemical, and functional properties of food, can be used to improve existing processes and to develop new ones. The combination of ultrasonic energy with a sanitizing agent can improve the effect of microbial reduction in foods and, thereby, their quality. Finally, it is concluded that the use of ultrasound in food is a very promising area of research; however, more research is still needed before applying this technology in a wider range of industrial sectors.

  9. Breast cancer: determining the genetic profile from ultrasound-guided percutaneous biopsy specimens obtained during the diagnostic workups.

    Science.gov (United States)

    López Ruiz, J A; Zabalza Estévez, I; Mieza Arana, J A

    2016-01-01

    To evaluate the possibility of determining the genetic profile of primary malignant tumors of the breast from specimens obtained by ultrasound-guided percutaneous biopsies during the diagnostic imaging workup. This is a retrospective study in 13 consecutive patients diagnosed with invasive breast cancer by B-mode ultrasound-guided 12 G core needle biopsy. After clinical indication, the pathologist decided whether the paraffin block specimens seemed suitable (on the basis of tumor size, validity of the sample, and percentage of tumor cells) before sending them for genetic analysis with the MammaPrint® platform. The size of the tumors on ultrasound ranged from 0.6cm to 5cm. In 11 patients the preserved specimen was considered valid and suitable for use in determining the genetic profile. In 1 patient (with a 1cm tumor) the pathologist decided that it was necessary to repeat the core biopsy to obtain additional samples. In 1 patient (with a 5cm tumor) the specimen was not considered valid by the genetic laboratory. The percentage of tumor cells in the samples ranged from 60% to 70%. In 11/13 cases (84.62%) it was possible to do the genetic analysis on the previously diagnosed samples. In most cases, regardless of tumor size, it is possible to obtain the genetic profile from tissue specimens obtained with ultrasound-guided 12 G core biopsy preserved in paraffin blocks. Copyright © 2015 SERAM. Published by Elsevier España, S.L.U. All rights reserved.

  10. Ultrasound-guided biopsy of the thickened peritoneal reflections: efficacy and diagnostic role in the differential diagnosis of peritoneal tuberculosis and peritoneal carcinomatosis

    International Nuclear Information System (INIS)

    Kim, Young Hwan; Ryeom, Hun Kyu; Chung, Tae Gyun; Park, Hyo Yong; Kim, Yong Joo; Kang, Duck Sik

    2000-01-01

    To evaluate the accuracy and safety of ultrasound-guided biopsy of the thickened peritoneal reflections and to determine the efficacy and diagnostic role of this procedure in the differential diagnosis of peritoneal tuberculosis and peritoneal carcinomatosis. Twenty-seven patients with only mildly thickened (25 mm or less) peritoneal reflections without apparent mass formations, and in whom imaging findings were not diagnostic, underwent ultrasound-guided biopsy. Five-MHz linear or convex linear array transducers were used for ultrasound guidance, and an automated gun with 18-gauge (n=3D23) or 20-gauge (n=3D4) needles for tissue sampling. biopsies were performed on the thickened parietal peritoneum (n=3D9), greater omentum (n=3D11), and small bowel mesentery (n=3D7), and the results were compared with the final diagnosis determined by radiologic/clinical follow-up (n=3D17) or laparoscopic biopsy (n=3D10). Complications and changes in hemoglobin and hematocrit levels after the procedure were evaluated. Specimens adequate for pathologic examination were obtained in all 27 patients. The histopathologic results were metastatic carcinomatosis (n=3D15), peritoneal tuberculosis (n=3D8), and chronic granulomatous inflammation (n=3D4). Specific pathologic diagnosis was obtained in all patients except the four with chronic granulomatous inflammation. Differentiation between benignancy and malignancy was possible in all patients and the histopathologic specific accuracy rate was 100%. No clinically significant complications were observed. In 24 patients with ascites at the site of the biopsy, transient bleeding was observed immediately after the procedure, but this stopped spontaneously within a few minutes. Post-procedural hemoglobin and hematocrit levels were only minimally lower (mean values of 0.9 g/dL and 3.0%, respectively) than pre-procedurally. Ultrasound-guided biopsy of thickened peritoneal reflections is a safe and effective diagnostic procedure and is useful in

  11. Ultrasound-guided biopsy of the thickened peritoneal reflections: efficacy and diagnostic role in the differential diagnosis of peritoneal tuberculosis and peritoneal carcinomatosis

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Young Hwan; Ryeom, Hun Kyu; Chung, Tae Gyun; Park, Hyo Yong; Kim, Yong Joo; Kang, Duck Sik [Kyungpook National University Hospital, Taegu (Korea, Republic of)

    2000-08-01

    To evaluate the accuracy and safety of ultrasound-guided biopsy of the thickened peritoneal reflections and to determine the efficacy and diagnostic role of this procedure in the differential diagnosis of peritoneal tuberculosis and peritoneal carcinomatosis. Twenty-seven patients with only mildly thickened (25 mm or less) peritoneal reflections without apparent mass formations, and in whom imaging findings were not diagnostic, underwent ultrasound-guided biopsy. Five-MHz linear or convex linear array transducers were used for ultrasound guidance, and an automated gun with 18-gauge (n=3D23) or 20-gauge (n=3D4) needles for tissue sampling. biopsies were performed on the thickened parietal peritoneum (n=3D9), greater omentum (n=3D11), and small bowel mesentery (n=3D7), and the results were compared with the final diagnosis determined by radiologic/clinical follow-up (n=3D17) or laparoscopic biopsy (n=3D10). Complications and changes in hemoglobin and hematocrit levels after the procedure were evaluated. Specimens adequate for pathologic examination were obtained in all 27 patients. The histopathologic results were metastatic carcinomatosis (n=3D15), peritoneal tuberculosis (n=3D8), and chronic granulomatous inflammation (n=3D4). Specific pathologic diagnosis was obtained in all patients except the four with chronic granulomatous inflammation. Differentiation between benignancy and malignancy was possible in all patients and the histopathologic specific accuracy rate was 100%. No clinically significant complications were observed. In 24 patients with ascites at the site of the biopsy, transient bleeding was observed immediately after the procedure, but this stopped spontaneously within a few minutes. Post-procedural hemoglobin and hematocrit levels were only minimally lower (mean values of 0.9 g/dL and 3.0%, respectively) than pre-procedurally. Ultrasound-guided biopsy of thickened peritoneal reflections is a safe and effective diagnostic procedure and is useful in

  12. Ultrasound in the investigation of posterior compartment vaginal prolapse and obstructed defecation.

    Science.gov (United States)

    Dietz, H P; Beer-Gabel, M

    2012-07-01

    Recent developments in diagnostic imaging have made gynecologists, colorectal surgeons and gastroenterologists realize as never before that they share a common interest in anorectal and pelvic floor dysfunction. While we often may be using different words to describe the same phenomenon (e.g. anismus/vaginismus) or attributing different meanings to the same words (e.g. rectocele), we look after patients with problems that transcend the borders of our respective specialties. Like no other diagnostic modality, imaging helps us understand each other and provides new insights into conditions we all need to learn to investigate better in order to improve clinical management. In this review we attempt to show what modern ultrasound imaging can contribute to the diagnostic work-up of patients with posterior vaginal wall prolapse, obstructed defecation and rectal intussusception/prolapse. In summary, it is evident that translabial/perineal ultrasound can serve as a first-line diagnostic tool in women with such complaints, replacing defecation proctography and MR proctography in a large proportion of female patients. This is advantageous for the women themselves because ultrasound is much better tolerated, as well as for healthcare systems since sonographic imaging is much less expensive. However, there is a substantial need for education, which currently remains unmet. Copyright © 2012 ISUOG. Published by John Wiley & Sons, Ltd.

  13. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... as needle biopsies and fluid aspiration. Risks For standard diagnostic ultrasound , there are no known harmful effects ... possible charges you will incur. Web page review process: This Web page is reviewed regularly by a ...

  14. General Ultrasound Imaging

    Medline Plus

    Full Text Available ... of the reflected sound waves (called the Doppler effect). A computer collects and processes the sounds and ... standard diagnostic ultrasound , there are no known harmful effects on humans. top of page What are the ...

  15. Which children could benefit from additional diagnostic tools in case of suspected appendicitis?

    NARCIS (Netherlands)

    van den Broek, W. T.; van der Ende, E. D.; Bijnen, A. B.; Breslau, P. J.; Gouma, D. J.

    2004-01-01

    Background: New diagnostic tools such as ultrasound scan, computed tomography (CT) scan, and diagnostic laparoscopy, have become available for children with suspected appendicitis but should be reserved for equivocal cases. The aim of this study was to develop a scoring system to identify this

  16. Usefulness of Ultrasound Examinations in the Diagnostics of Necrotizing Enterocolitis

    International Nuclear Information System (INIS)

    Staryszak, Joanna; Stopa, Joanna; Kucharska-Miąsik, Iwona; Osuchowska, Magdalena; Guz, Wiesław; Błaż, Witold

    2015-01-01

    Necrotizing enterocolitis (NEC) is one of the most serious disorders of gastrointestinal tract during neonatal period. Early diagnosis and adequate treatment are essential in the presence of clinical suspicion of NEC. Plain abdominal radiography is currently the modality of choice for initial evaluation of gastrointestinal tract in neonates. However, when the diagnosis is uncertain, abdominal ultrasound with bowel assessment might be an important complementary examination. The aim of the study was to evaluate usefulness of ultrasound in the diagnosis of NEC and its value for implementation of proper treatment. The data of nine neonates diagnosed with NEC, hospitalized at the Provincial Hospital No. 2 in Rzeszow in the period from September 2009 to April 2013 was retrospectively analyzed. Apart from abdominal radiography, abdominal ultrasound with bowel assessment was performed in all nine cases. Imaging findings, epidemiological data, coexisting risk factors and disease course were assessed. Most children in the group were preterm neonates. Findings in plain abdominal radiography were normal or nonspecific. A wider spectrum of findings was demonstrated in all ultrasound examinations and intestinal pneumatosis, a pathognomonic sign for NEC, was more frequently noted than in plain abdominal x-ray. Most children were treated by surgical intervention with resection of necrotic bowel loops and in more than half of the cases location of changes identified during surgery was concordant with ultrasonographic findings. Abdominal ultrasound examination might be helpful in the diagnosis of NEC, especially when plain abdominal radiography findings do not correlate with clinical symptoms. However, abdominal radiography is still considered the modality of choice. The range of morphological changes detectable on ultrasound examination is much wider than in plain abdominal radiography. Ultrasound examination allows for more accurate assessment of changes within intestines and

  17. Utilization of diagnostic ultrasound and intravenous lipid-encapsulated perfluorocarbons in non-invasive targeted cardiovascular therapeutics.

    Science.gov (United States)

    Porter, Thomas R; Choudhury, Songita A; Xie, Feng

    2016-01-01

    Diagnostic ultrasound (DUS) pressures have the ability to induce inertial cavitation (IC) of systemically administered microbubbles; this bioeffect has many diagnostic and therapeutic implications in cardiovascular care. Diagnostically, commercially available lipid-encapsulated perfluorocarbons (LEP) can be utilized to improve endocardial and vascular border delineation as well as assess myocardial perfusion. Therapeutically, the liquid jets induced by IC can alter endothelial function and dissolve thrombi within the immediate vicinity of the cavitating microbubbles. The cavitating LEP can also result in the localized release of any bound therapeutic substance at the site of insonation. DUS-induced IC has been tested in pre-clinical studies to determine what effect it has on acute vascular and microvascular thrombosis as well as nitric oxide (NO) release. These pre-clinical studies have consistently shown that DUS-induced IC of LEP is effective in restoring coronary vascular and microvascular flow in acute ST segment elevation myocardial infarction (STEMI), with microvascular flow improving even if upstream large vessel flow has not been achieved. The initial clinical trials examining the efficacy of short pulse duration DUS high mechanical index impulses in patients with STEMI are underway, and preliminary studies have suggested that earlier epicardial vessel recanalization can be achieved prior to arriving in the cardiac catheterization laboratory. DUS high mechanical index impulses have also been effective in pre-clinical studies for targeting DNA delivery that has restored islet cell function in type I diabetes and restored vascular flow in the extremities downstream from a peripheral vascular occlusion. Improvements in this technique will come from three dimensional arrays for therapeutic applications, more automated delivery techniques that can be applied in the field, and use of submicron-sized acoustically activated LEP droplets that may better permeate the

  18. THE POSSIBILITIES TO DETERMINE FETAL MATURITY BY ULTRASOUND DIAGNOSTICS

    Directory of Open Access Journals (Sweden)

    S. N. Lysenko

    2015-01-01

    Full Text Available Background: Extragenital disorders in a pregnant patient, as well as complications of pregnancy often necessitate preterm delivery, when the state of the fetus is one of the criteria determining terms and type of delivery. In connection with this, the physician faces the challenge of accurate assessment of fetal maturity. Aim: To identify ultrasound signs of functional fetal maturity. Materials and methods: 120 pregnant patients were assessed at 35 to 40 weeks of gestation. Beyond a standard fetometry, we assessed interhemispheric cerebellar size, the biggest size of the Beclard’s nucleus, the ratio of cortical to medullar substance of fetal adrenal glands (adrenal coefficient, the ration between ultrasound density of lungs, liver and ultrasound density of fetal urine (histogram analysis. Results: Up to 36 weeks of gestation, the interhemispheric cerebellar size was below 52 mm, starting from 37 weeks, above 53 mm and from week 40 on, above 58 mm. All newborns, which had their interhemispheric cerebellar size ≥ 53 mm antenatally, were assessed as being mature at birth (p < 0.05. All newborns, which had Beclard’s nucleus size ≥ 5 mm antenatally, were assessed as being mature at birth (p < 0.05. At 35–35.6 weeks of gestation, mean adrenal coefficients in all cases exceeded 1. Starting with full 36 weeks of gestation onwards, this parameter decreased to 0.94 and showed a steady decrease thereafter. There were no signs of functional immaturity or respiratory distress among newborns with antenatal adrenal coefficient of ≤ 0.99 (p < 0.05. The ratio between ultrasound density of lungs to ultrasound density of bladder contents increases up to 37 weeks of gestation and remains stable up to 40 weeks. The ratio of liver density to the same substrate is non-significantly lower due to lower ultrasound density of the liver itself. The ratio of ultrasound density of the lung to that of the liver up to 36 weeks was at least 1.41 and decreased

  19. Spatially Resolved MR-Compatible Doppler Ultrasound: Proof of Concept for Triggering of Diagnostic Quality Cardiovascular MRI for Function and Flow Quantification at 3T.

    Science.gov (United States)

    Crowe, Lindsey Alexandra; Manasseh, Gibran; Chmielewski, Aneta; Hachulla, Anne-Lise; Speicher, Daniel; Greiser, Andreas; Muller, Hajo; de Perrot, Thomas; Vallee, Jean-Paul; Salomir, Rares

    2018-02-01

    We demonstrate the use of a magnetic-resonance (MR)-compatible ultrasound (US) imaging probe using spatially resolved Doppler for diagnostic quality cardiovascular MR imaging (MRI) as an initial step toward hybrid US/MR fetal imaging. A newly developed technology for a dedicated MR-compatible phased array ultrasound-imaging probe acquired pulsed color Doppler carotid images, which were converted in near-real time to a trigger signal for cardiac cine and flow quantification MRI. Ultrasound and MR data acquired simultaneously were interference free. Conventional electrocardiogram (ECG) and the proposed spatially resolved Doppler triggering were compared in 10 healthy volunteers. A synthetic "false-triggered" image was retrospectively processed using metric optimized gating (MOG). Images were scored by expert readers, and sharpness, cardiac function and aortic flow were quantified. Four-dimensional (4-D) flow (two volunteers) showed feasibility of Doppler triggering over a long acquisition time. Imaging modalities were compatible. US probe positioning was stable and comfortable. Image quality scores and quantified sharpness were statistically equal for Doppler- and ECG-triggering (p ). ECG-, Doppler-triggered, and MOG ejection fractions were equivalent (p ), with false-triggered values significantly lower (p 0.05). 4-D flow quantification gave consistent results between ECG and Doppler triggering. We report interference-free pulsed color Doppler ultrasound during MR data acquisition. Cardiovascular MRI of diagnostic quality was successfully obtained with pulsed color Doppler triggering. The hardware platform could further enable advanced free-breathing cardiac imaging. Doppler ultrasound triggering is applicable where ECG is compromised due to pathology or interference at higher magnetic fields, and where direct ECG is impossible, i.e., fetal imaging.

  20. Comparison of the diagnostic value of FDG-PET/CT and axillary ultrasound for the detection of lymph node metastases in breast cancer patients

    International Nuclear Information System (INIS)

    Riegger, Carolin; Heusner, Till A.; Koeninger, Angela; Kimmig, Rainer; Hartung, Verena; Bockisch, Andreas; Otterbach, Friedrich; Forsting, Michael; Antoch, Gerald

    2012-01-01

    Background. FDG-PET/CT is increasingly being used for breast cancer staging. Its diagnostic accuracy in comparison to ultrasound as the standard non-invasive imaging modality for the evaluation of axillary lymph nodes has yet not been evaluated. Purpose. To retrospectively compare the diagnostic value of full-dose, intravenously contrast-enhanced FDG-PET/CT and ultrasound for the detection of lymph node metastases in breast cancer patients. Material and Methods. Ninety patients (one patient with a bilateral carcinoma) (89 women, one man; mean age, 55.5 ± 16.6 years) suffering from primary breast cancer underwent whole-body FDG-PET/CT and axillary ultrasound. The ipsilateral axillary fossa (n = 91) was evaluated for metastatic spread. The sensitivity, specificity, the positive predictive value (PPV), negative predictive value (NPV), and accuracy of both methods were calculated. The sensitivity and accuracy were statistically compared using the McNemar Test (P <0.05). Analyses were made on a patient basis. The number of patients with extra-axillary locoregional lymph node metastases exclusively detected by FDG-PET/CT was evaluated. For axillary lymph node metastases histopathology served as the reference standard. Results. The sensitivity, specificity, PPV, NPV, and accuracy of FDG-PET/CT for the detection of axillary lymph node metastases were 54%, 89%, 77%, 74%, and 75%, respectively. For ultrasound it was 38%, 78%, 54%, 65%, and 62%, respectively. FDG-PET/CT was significantly more accurate than ultrasound for the detection of axillary lymph node metastases (P = 0.019). There was no statistically significant difference between the sensitivity of both modalities (P = 0.0578). FDG-PET/CT detected extra-axillary locoregional lymph node metastases in seven patients (8%) that had not been detected by another imaging modality. Conclusion. Though more accurate compared to ultrasound for evaluating the axillary lymph node status FDG-PET/CT is only as sensitive as

  1. Pelvicalyceal system duplication with ectopic ureter – diagnostic difficulties associated with the imaging procedure. Two cases report

    Directory of Open Access Journals (Sweden)

    Agnieszka Pukajło-Marczyk

    2014-09-01

    Full Text Available Urinary tract abnormalities are the most frequently occurring developmental anomaly in children. Pelvicalyceal system duplication is one of them and signifies the existence of two urine diverting separate systems. This anomaly occurs in 10% of population, usually in girls, and is associated with complete or partial ureter duplication. The frequency of total ureter duplication, which in 20–40% of patients is found as bilateral, is 1:125 children (0.8% of the population. The most frequent malformation is asymptomatic, diagnosed coincidentally casually and does not require any treatment. In some patients with pelvicalyceal system duplication, vesicoureteral reflux (VUR and ectopic ureter may coexist. Malposition of ureter’s orifice into the bladder predispose to urinary retention, development of hydronephrosis and urinary tract infection (UTI. Ectopic ureterocele is recognized in 6–20% of children with recurrent UTI. The reason why children are referred to the hospital is UTI or hydronephrosis revealed by ultrasound imaging. When the ultrasound image of pelvicalyceal system duplication is ambiguous, micturating cystourethrography (MCU and scintigraphy become the primary diagnostic procedure, or urography – in more complicated cases. In the case of ectopic ureter, the danger of inappropriate catheterization, i.e. directly into its lumen, may occur. Though very rare, this may cause some diagnostic difficulties and lead to injury of the urinary tract. For this reason, we want to further discuss this complication following a diagnostic procedure on the example of two cases of pelvicalyceal system duplication with ectopic ureter.

  2. Investigation of childhood blunt abdominal trauma: A practical approach using ultrasound as the initial diagnostic modality

    International Nuclear Information System (INIS)

    Filiatrault, D.; Longpre, D.; Patriquin, H.; Perreault, G.; Grignon, A.; Pronovost, J.; Boisvert, J.

    1987-01-01

    During a 5.5-year retrospective study (1979-84) 170 children with blunt abdominal trauma were investigated with intravenous urography (IVU), ultrasound (US) and scintigraphy. For the investigation of the last 71 children (after 1982) a 4th generation CT scanner was available in the same department. The results of radiologic investigations were compared with clinical outcome in 157 and results at laparotomy in 13 children. During the study period, real time US became the first line screening tool, and was combined with IVU in suspected renal trauma. In spite of permanent accessibility of CT since November 1982, the latter was used only in complex diagnostic problems or in children with multiple injuries (8% of the series). There were no deaths resulting from abdominal trauma. During the study, the incidence of splenectomy and exploratory laparotomy decreased, and no diagnostic peritoneal lavage was performed after 1980. (orig.)

  3. Ultrasound Vector Flow Imaging: Part II: Parallel Systems

    DEFF Research Database (Denmark)

    Jensen, Jørgen Arendt; Nikolov, Svetoslav Ivanov; Yu, Alfred C. H.

    2016-01-01

    The paper gives a review of the current state-of-theart in ultrasound parallel acquisition systems for flow imaging using spherical and plane waves emissions. The imaging methods are explained along with the advantages of using these very fast and sensitive velocity estimators. These experimental...... ultrasound imaging for studying brain function in animals. The paper explains the underlying acquisition and estimation methods for fast 2-D and 3-D velocity imaging and gives a number of examples. Future challenges and the potentials of parallel acquisition systems for flow imaging are also discussed....

  4. Objective and structured assessment of lung ultrasound competence

    DEFF Research Database (Denmark)

    Skaarup, Søren Helbo; Laursen, Christian B.; Bjerrum, Anne Sofie

    2017-01-01

    RATIONALE: Point-of-care lung ultrasound imaging has substantial diagnostic value and is widely used in respiratory, emergency and critical care medicine. Like other ultrasound examinations, lung ultrasound is operator-dependent. The current recommendations for competence in lung ultrasound sets...... a fixed number of ultrasound procedures to be performed without considering different learning rates. Recommendations do not consider different uses of lung ultrasound across specialties. OBJECTIVE: To create a reliable, valid and feasible instrument to assess lung ultrasound competence that includes...... 23 ultrasound operators of different competence levels. Examination time was measured and skill was rated by experienced observers using the assessment tool. Inter-rater agreement was examined by two observers in 9 lung ultrasound examinations. RESULTS: Consensus was obtained within 3 Delphi rounds...

  5. Comparison of Thresholds for Pulmonary Capillary Hemorrhage Induced by Pulsed-wave and B-mode Ultrasound

    Science.gov (United States)

    Miller, Douglas L.; Dou, Chunyan; Raghavendran, Krishnan

    Pulsed ultrasound was found to induce pulmonary capillary hemorrhage (PCH) in mice about 25 years ago but remains a poorly understood risk factor for pulmonary diagnostic ultrasound. In early research using laboratory fixed beam ultrasound, thresholds for PCH had frequency variation from 1-4 MHz similar to the Mechanical Index. In recent research, thresholds for B mode diagnostic ultrasound from 1.5-12 MHz had little dependence on frequency. To compare the diagnostic ultrasound method to laboratory pulsed exposure, thresholds for fixed beam ultrasound were determined using comparable methods at 1.5 and 7.5 MHz. PCH thresholds were lower for simple fixed-beam pulse modes than for B mode and in approximate agreement with early research. However, for comparable timing parameters, PCH thresholds had little dependence on ultrasonic frequency. These findings suggest that the MI may not be directly useful as a dosimetric parameter for safety guidance in pulmonary ultrasound.

  6. The therapeutic impact of abdominal ultrasound in patients with acute abdominal symptoms

    International Nuclear Information System (INIS)

    Dhillon, S.; Halligan, S.; Goh, V.; Matravers, P.; Chambers, A.; Remedios, D.

    2002-01-01

    AIM: The technical performance of abdominal ultrasound in the investigation of acute abdominal pain has been thoroughly investigated but its therapeutic effects are less well understood. We aimed to determine the therapeutic effect of abdominal ultrasound in the investigation of acute abdominal pain. MATERIAL AND METHODS: A pre- and post-intervention observational study design was used to determine the diagnostic and therapeutic effects of abdominal ultrasound for acute abdominal pain. Referring clinicians completed a pre-ultrasound questionnaire that detailed their leading diagnosis, confidence in this and intended management in 100 consecutive adult patients. Following ultrasound a second questionnaire was completed. This again detailed the leading diagnosis, confidence in this and their intended management. Clinicians quantified the management contribution of ultrasound both for the individual case in question and in their clinical experience generally. RESULTS: The leading diagnosis was either confirmed or rejected in 72 patients and a new diagnosis provided where no prior differential diagnosis existed in 10. Diagnostic confidence increased significantly following ultrasound (mean score 6·5 pre-ultrasound vs 7·6 post-ultrasound, P < 0·001). Intended management changed following ultrasound in 22 patients; 15 intended laparotomies were halted and a further seven patients underwent surgery where this was not originally intended. Ultrasound was rated either 'very' or 'moderately' helpful in 87% of patients, with 99% of clinicians finding it either 'very' or 'moderately' helpful generally. CONCLUSION: Abdominal ultrasound has considerable diagnostic and therapeutic effect in the setting of acute abdominal pain. Dhillon, S. et al. (2002)

  7. Design and development of an ultrasound calibration phantom and system

    Science.gov (United States)

    Cheng, Alexis; Ackerman, Martin K.; Chirikjian, Gregory S.; Boctor, Emad M.

    2014-03-01

    Image-guided surgery systems are often used to provide surgeons with informational support. Due to several unique advantages such as ease of use, real-time image acquisition, and no ionizing radiation, ultrasound is a common medical imaging modality used in image-guided surgery systems. To perform advanced forms of guidance with ultrasound, such as virtual image overlays or automated robotic actuation, an ultrasound calibration process must be performed. This process recovers the rigid body transformation between a tracked marker attached to the ultrasound transducer and the ultrasound image. A phantom or model with known geometry is also required. In this work, we design and test an ultrasound calibration phantom and software. The two main considerations in this work are utilizing our knowledge of ultrasound physics to design the phantom and delivering an easy to use calibration process to the user. We explore the use of a three-dimensional printer to create the phantom in its entirety without need for user assembly. We have also developed software to automatically segment the three-dimensional printed rods from the ultrasound image by leveraging knowledge about the shape and scale of the phantom. In this work, we present preliminary results from using this phantom to perform ultrasound calibration. To test the efficacy of our method, we match the projection of the points segmented from the image to the known model and calculate a sum squared difference between each point for several combinations of motion generation and filtering methods. The best performing combination of motion and filtering techniques had an error of 1.56 mm and a standard deviation of 1.02 mm.

  8. Ergonomic design and evaluation of a diagnostic ultrasound transducer holder.

    Science.gov (United States)

    Ghasemi, Mohamad Sadegh; Hosseinzadeh, Payam; Zamani, Farhad; Ahmadpoor, Hossein; Dehghan, Naser

    2017-12-01

    Work-related musculoskeletal disorders (WMSDs) are injuries and disorders that affect the body's movement and musculoskeletal system. Awkward postures represent one of the major ergonomic risk factors that cause WMSDs among sonographers while working with an ultrasound transducer. This study aimed to design and evaluate a new holder for the ultrasound transducer. In the first phase a new holder was designed for the transducer, considering design principles. Evaluation of the new holder was then carried out by electrogoniometry and a locally perceived discomfort (LPD) scale. The application of design principles to the new holder resulted in an improvement of wrist posture and comfort. Wrist angles in extension, flexion, radial deviation and ulnar deviation were lower with utilization of the new holder. The severity of discomfort based on the LPD method in the two modes of work with and without the new holder was reported with values of 1.3 and 1.8, respectively (p ergonomics design principles was effective in minimizing wrist deviation and increasing comfort while working with the new holder.

  9. Chest Ultrasound Integrated Teaching of Respiratory System Physiology to Medical Students: A First Experience

    Science.gov (United States)

    Paganini, M.; Rubini, A.

    2015-01-01

    Ultrasound imaging is a useful diagnostic technique that has spread among several different medical specialties within the last few years. Initially restricted to radiology, cardiology, obstetrics, and gynecology, today it is widely used by many specialists, especially in critical care. New graduate physicians will need to be comfortable with…

  10. Verification and compensation of respiratory motion using an ultrasound imaging system

    International Nuclear Information System (INIS)

    Chuang, Ho-Chiao; Hsu, Hsiao-Yu; Chiu, Wei-Hung; Tien, Der-Chi; Wu, Ren-Hong; Hsu, Chung-Hsien

    2015-01-01

    Purpose: The purpose of this study was to determine if it is feasible to use ultrasound imaging as an aid for moving the treatment couch during diagnosis and treatment procedures associated with radiation therapy, in order to offset organ displacement caused by respiratory motion. A noninvasive ultrasound system was used to replace the C-arm device during diagnosis and treatment with the aims of reducing the x-ray radiation dose on the human body while simultaneously being able to monitor organ displacements. Methods: This study used a proposed respiratory compensating system combined with an ultrasound imaging system to monitor the compensation effect of respiratory motion. The accuracy of the compensation effect was verified by fluoroscopy, which means that fluoroscopy could be replaced so as to reduce unnecessary radiation dose on patients. A respiratory simulation system was used to simulate the respiratory motion of the human abdomen and a strain gauge (respiratory signal acquisition device) was used to capture the simulated respiratory signals. The target displacements could be detected by an ultrasound probe and used as a reference for adjusting the gain value of the respiratory signal used by the respiratory compensating system. This ensured that the amplitude of the respiratory compensation signal was a faithful representation of the target displacement. Results: The results show that performing respiratory compensation with the assistance of the ultrasound images reduced the compensation error of the respiratory compensating system to 0.81–2.92 mm, both for sine-wave input signals with amplitudes of 5, 10, and 15 mm, and human respiratory signals; this represented compensation of the respiratory motion by up to 92.48%. In addition, the respiratory signals of 10 patients were captured in clinical trials, while their diaphragm displacements were observed simultaneously using ultrasound. Using the respiratory compensating system to offset, the diaphragm

  11. Development of JT-60 diagnostics system

    International Nuclear Information System (INIS)

    Suzuki, Yasuo

    1988-01-01

    The various kinds of plasma diagnostics have been developed and utilized in the JT-60 experiments. The features of JT-60 diagnostics system and the historical proceeding of the development are described in this paper. Taking account of the design consideration, JT-60 diagnostics system is sorted out into eight groups, which include six diagnostics systems, the data processing system and diagnostics supporting system. The all devices in the JT-60 diagnostics system were instrumented on schedule in the end of the fiscal year of 1985 and have contributed to JT-60 experiments. (author)

  12. Automated assessment of joint synovitis activity from medical ultrasound and power doppler examinations using image processing and machine learning methods

    Directory of Open Access Journals (Sweden)

    Rafal Cupek

    2016-11-01

    Full Text Available Objectives : Rheumatoid arthritis is the most common rheumatic disease with arthritis, and causes substantial functional disability in approximately 50% patients after 10 years. Accurate measurement of the disease activity is crucial to provide an adequate treatment and care to the patients. The aim of this study is focused on a computer aided diagnostic system that supports an assessment of synovitis severity. Material and methods : This paper focus on a computer aided diagnostic system that was developed within joint Polish–Norwegian research project related to the automated assessment of the severity of synovitis. Semiquantitative ultrasound with power Doppler is a reliable and widely used method of assessing synovitis. Synovitis is estimated by ultrasound examiner using the scoring system graded from 0 to 3. Activity score is estimated on the basis of the examiner’s experience or standardized ultrasound atlases. The method needs trained medical personnel and the result can be affected by a human error. Results : The porotype of a computer-aided diagnostic system and algorithms essential for an analysis of ultrasonic images of finger joints are main scientific output of the MEDUSA project. Medusa Evaluation System prototype uses bone, skin, joint and synovitis area detectors for mutual structural model based evaluation of synovitis. Finally, several algorithms that support the semi-automatic or automatic detection of the bone region were prepared as well as a system that uses the statistical data processing approach in order to automatically localize the regions of interest. Conclusions : Semiquantitative ultrasound with power Doppler is a reliable and widely used method of assessing synovitis. Activity score is estimated on the basis of the examiner’s experience and the result can be affected by a human error. In this paper we presented the MEDUSA project which is focused on a computer aided diagnostic system that supports an

  13. Ultrasound mediated nanoparticle drug delivery

    Science.gov (United States)

    Mullin, Lee B.

    Ultrasound is not only a powerful diagnostic tool, but also a promising therapeutic technology that can be used to improve localized drug delivery. Microbubble contrast agents are micron sized encapsulated gas filled bubbles that are administered intravenously. Originally developed to enhance ultrasound images, microbubbles are highly echogenic due to the gas core that provides a detectable impedance difference from the surrounding medium. The core also allows for controlled response of the microbubbles to ultrasound pulses. Microbubbles can be pushed using acoustic radiation force and ruptured using high pressures. Destruction of microbubbles can increase permeability at the cellular and vascular level, which can be advantageous for drug delivery. Advances in drug delivery methods have been seen with the introduction of nanoparticles, nanometer sized objects often carrying a drug payload. In chemotherapy, nanoparticles can deliver drugs to tumors while limiting systemic exposure due to abnormalities in tumor vasculature such large gaps between endothelial cells that allow nanoparticles to enter into the interstitial space; this is referred to as the enhanced permeability and retention (EPR) effect. However, this effect may be overestimated in many tumors. Additionally, only a small percentage of the injected dose accumulates in the tumor, which most the nanoparticles accumulating in the liver and spleen. It is hypothesized that combining the acoustic activity of an ultrasound contrast agent with the high payload and extravasation ability of a nanoparticle, localized delivery to the tumor with reduced systemic toxicity can be achieved. This method can be accomplished by either loading nanoparticles onto the shell of the microbubble or through a coadministration method of both nanoparticles and microbubbles. The work presented in this dissertation utilizes novel and commercial nanoparticle formulations, combined with microbubbles and a variety of ultrasound systems

  14. Initial results of the FUSION-X-US prototype combining 3D automated breast ultrasound and digital breast tomosynthesis.

    Science.gov (United States)

    Schaefgen, Benedikt; Heil, Joerg; Barr, Richard G; Radicke, Marcus; Harcos, Aba; Gomez, Christina; Stieber, Anne; Hennigs, André; von Au, Alexandra; Spratte, Julia; Rauch, Geraldine; Rom, Joachim; Schütz, Florian; Sohn, Christof; Golatta, Michael

    2018-06-01

    To determine the feasibility of a prototype device combining 3D-automated breast ultrasound (ABVS) and digital breast tomosynthesis in a single device to detect and characterize breast lesions. In this prospective feasibility study, the FUSION-X-US prototype was used to perform digital breast tomosynthesis and ABVS in 23 patients with an indication for tomosynthesis based on current guidelines after clinical examination and standard imaging. The ABVS and tomosynthesis images of the prototype were interpreted separately by two blinded experts. The study compares the detection and BI-RADS® scores of breast lesions using only the tomosynthesis and ABVS data from the FUSION-X-US prototype to the results of the complete diagnostic workup. Image acquisition and processing by the prototype was fast and accurate, with some limitations in ultrasound coverage and image quality. In the diagnostic workup, 29 solid lesions (23 benign, including three cases with microcalcifications, and six malignant lesions) were identified. Using the prototype, all malignant lesions were detected and classified as malignant or suspicious by both investigators. Solid breast lesions can be localized accurately and fast by the Fusion-X-US system. Technical improvements of the ultrasound image quality and ultrasound coverage are needed to further study this new device. The prototype combines tomosynthesis and automated 3D-ultrasound (ABVS) in one device. It allows accurate detection of malignant lesions, directly correlating tomosynthesis and ABVS data. The diagnostic evaluation of the prototype-acquired data was interpreter-independent. The prototype provides a time-efficient and technically reliable diagnostic procedure. The combination of tomosynthesis and ABVS is a promising diagnostic approach.

  15. Ultrasound of musculoskeletal soft-tissue tumors superficial to the investing fascia.

    Science.gov (United States)

    Hung, Esther Hiu Yee; Griffith, James Francis; Ng, Alex Wing Hung; Lee, Ryan Ka Lok; Lau, Domily Ting Yi; Leung, Jason Chi Shun

    2014-06-01

    The objective of our study was to evaluate the diagnostic accuracy of ultrasound in assessing musculoskeletal soft-tissue tumors superficial to the investing fascia. Seven hundred fourteen superficial soft-tissue tumors evaluated with ultrasound by two musculoskeletal radiologists were retrospectively reviewed. In all ultrasound reports, the reporting radiologists provided one, two, or three diagnoses depending on their perceived level of diagnostic certainty. Two hundred forty-seven tumors had subsequent histologic correlation, thus allowing the accuracy of the ultrasound diagnosis to be determined. Images of the lesions with a discordant ultrasound diagnosis and histologic diagnosis were reviewed, and the ultrasound features were further classified as concordant with the known histologic diagnosis, concordant with the known histologic diagnosis with atypical features present, or discordant with the known histologic diagnosis. Four hundred sixty-seven tumors without pathologic confirmation were followed up clinically. Overall the accuracy of ultrasound examination for assessing superficial soft-tissue masses was 79.0% when all differential diagnoses were considered and 77.0% when only the first differential diagnosis was considered. The sensitivity and specificity of the first ultrasound diagnosis were 95.2% and 94.3%, respectively, for lipoma; 73.0% and 97.7% for vascular malformation; 80.0% and 95.4% for epidermoid cyst; and 68.8% and 95.2% for nerve sheath tumor. Reduced observer awareness of specific tumor entities tended to contribute to underdiagnosis more than poor specificity of ultrasound findings. Most tumors (236/247, 96%) were benign. The sensitivity and specificity of ultrasound for identifying malignant superficial soft-tissue tumors was 94.1% and 99.7%, respectively. The diagnostic accuracy of ultrasound in the assessment of superficial musculoskeletal soft-tissue tumors is high and can be improved through increased radiologist awareness of less

  16. Emergency medicine physicians performed ultrasound for pediatric intussusceptions

    Directory of Open Access Journals (Sweden)

    Yi-Jung Chang

    2013-08-01

    Full Text Available Background: Intussusception is the common acute abdomen in children with difficult clinical diagnosis. The routine ultrasound has recently been proposed as the initial diagnostic modality with high accuracy, but is not available for 24 h by gastroenterologists. We aimed to evaluate the validation of bedside ultrasound for intussusceptions performed by pediatric emergency physicians with ultrasound training during the night or holiday. Methods: A retrospective study was conducted in children with suspected intussusceptions when routine ultrasounds by gastroenterologists were not available over the period from July 2004 to July 2008. Patients were divided into two groups: those diagnosed by emergency physicians with ultrasound training and without training. The clinical characteristics and course for all patients were reviewed and compared for seeking the difference. Results: A total of 186 children were included. One hundred and thirteen (61% children were diagnosed by pediatric emergency physician with ultrasound training. The clinical symptoms were not statistically different between the two groups. The diagnostic sensitivity of the ultrasound training group was significantly higher (90% vs. 79%, p = 0.034. Children of the training group also had significantly shorter hospital stay duration at emergency departments before reduction (2.41 ± 2.01 vs. 4.58 ± 4.80 h, p = 0.002. Conclusion: Bedside ultrasound performed by pediatric emergency physicians with ultrasound training is a sensitive test for detecting intussusceptions. Knowledge and use of bedside ultrasound can aid the emergency physician in the diagnosis of pediatric intussusceptions with less delay in treatment.

  17. Feasibility of dynamic cardiac ultrasound transmission via mobile phone for basic emergency teleconsultation.

    Science.gov (United States)

    Lim, Tae Ho; Choi, Hyuk Joong; Kang, Bo Seung

    2010-01-01

    We assessed the feasibility of using a camcorder mobile phone for teleconsulting about cardiac echocardiography. The diagnostic performance of evaluating left ventricle (LV) systolic function was measured by three emergency medicine physicians. A total of 138 short echocardiography video sequences (from 70 subjects) was selected from previous emergency room ultrasound examinations. The measurement of LV ejection fraction based on the transmitted video displayed on a mobile phone was compared with the original video displayed on the LCD monitor of the ultrasound machine. The image quality was evaluated using the double stimulation impairment scale (DSIS). All observers showed high sensitivity. There was an improvement in specificity with the observer's increasing experience of cardiac ultrasound. Although the image quality of video on the mobile phone was lower than that of the original, a receiver operating characteristic (ROC) analysis indicated that there was no significant difference in diagnostic performance. Immediate basic teleconsulting of echocardiography movies is possible using current commercially-available mobile phone systems.

  18. Development of estimation system of knee extension strength using image features in ultrasound images of rectus femoris

    Science.gov (United States)

    Murakami, Hiroki; Watanabe, Tsuneo; Fukuoka, Daisuke; Terabayashi, Nobuo; Hara, Takeshi; Muramatsu, Chisako; Fujita, Hiroshi

    2016-04-01

    The word "Locomotive syndrome" has been proposed to describe the state of requiring care by musculoskeletal disorders and its high-risk condition. Reduction of the knee extension strength is cited as one of the risk factors, and the accurate measurement of the strength is needed for the evaluation. The measurement of knee extension strength using a dynamometer is one of the most direct and quantitative methods. This study aims to develop a system for measuring the knee extension strength using the ultrasound images of the rectus femoris muscles obtained with non-invasive ultrasonic diagnostic equipment. First, we extract the muscle area from the ultrasound images and determine the image features, such as the thickness of the muscle. We combine these features and physical features, such as the patient's height, and build a regression model of the knee extension strength from training data. We have developed a system for estimating the knee extension strength by applying the regression model to the features obtained from test data. Using the test data of 168 cases, correlation coefficient value between the measured values and estimated values was 0.82. This result suggests that this system can estimate knee extension strength with high accuracy.

  19. Performance Evaluation of a Synthetic Aperture Real-Time Ultrasound System

    DEFF Research Database (Denmark)

    Stuart, Matthias Bo; Tomov, Borislav Gueorguiev; Jensen, Jørgen Arendt

    2011-01-01

    This paper evaluates the signal-to-noise ratio, the time stability, and the phase difference of the sampling in the experimental ultrasound scanner SARUS: A synthetic aperture, real-time ultrasound system. SARUS has 1024 independent transmit and receive channels and is capable of handling 2D probes...... arrays (FPGAs) making it very flexible and allowing implementation of other real-time ultrasound processing methods in the future. For conventional B-mode imaging, a penetration depth around 7 cm for a 7 MHz transducer is obtained (signal-tonoise ratio of 0 dB), which is comparable to commercial...... for 3D ultrasound imaging. It samples at 12 bits per sample and has a sampling rate of 70 MHz with the possibility of decimating the sampling frequency at the input. SARUS is capable of advanced real-time computations such as synthetic aperture imaging. The system is built using fieldprogrammable gate...

  20. Essure microinsert imaging: does abnormal shape on ultrasound predict complications on HSG?

    Science.gov (United States)

    VanBuren, Wendaline M; Suchet, Ian B; Thiel, John A; Karreman, Erwin

    2016-12-01

    We hypothesize that the shape of the Essure microinsert on ultrasound is able to predict complications evident on hysterosalpingogram (HSG), the accepted gold standard. From July 2, 2009 to July 2, 2012, 441 women at our institution received Essure microinsert placement for the purpose of permanent sterilization. 2D and 3D coronal plane transvaginal ultrasounds were performed three months after Essure microinsert placement. Those patients with complications identified on ultrasound, a non-diagnostic ultrasound, or following a difficult insertion were referred for HSG. Patients with both HSG and ultrasound performed were retrospectively selected and anonymized. The ultrasounds were reviewed by a single, blinded radiologist. A total of 122 microinserts in 65 patients were described on ultrasound using a numeric grading system and compared to HSG findings. Microinsert placement resulted in 37 complications, 31 of which were identified on ultrasound, including uterine and tubal perforations and placement in the endometrial cavity. The sensitivity of Essure microinsert shape on ultrasound in predicting complications, compared with standard HSG, was 94%, with a positive predictive value of 85%; specificity was 95%, with a negative predictive value of 98%. The Kappa coefficient was 0.85 (p Essure microinsert placement.

  1. The role of contrast-enhanced ultrasound in risk assessment of carotid atheroma

    Directory of Open Access Journals (Sweden)

    Silviu Stanciu

    2016-07-01

    Full Text Available Background and objective: Contrast-enhanced ultrasound, used to assess atherosclerotic carotid plaques, improves visualization of vessel wall irregularities and depicts intraplaque neovascularization. This article illustrates the use of contrast-enhanced ultrasound in the risk assessment of carotid atherosclerotic lesions, especially in challenging plaques evaluation. Materials and methods: For 23 patients with difficult duplex ultrasound examination due to carotid tortuosity or calcifications we assessed plaque morphology (contour, echogenicity and stenosis degree using contrast substance (Sonovue, Braco with dedicated vascular low mechanical index CPC software. Conclusion: Contrast-enhanced ultrasound is a new, noninvasive, and safe procedure for imaging carotid atherosclerotic lesions. It is a valuable tool for evaluating the vulnerable plaque at risk for rupture and for the diagnostic of the development and severity of systemic atherosclerotic disease

  2. Cavitation and contrast: the use of bubbles in ultrasound imaging and therapy.

    Science.gov (United States)

    Stride, E P; Coussios, C C

    2010-01-01

    Microbubbles and cavitation are playing an increasingly significant role in both diagnostic and therapeutic applications of ultrasound. Microbubble ultrasound contrast agents have been in clinical use now for more than two decades, stimulating the development of a range of new contrast-specific imaging techniques which offer substantial benefits in echocardiography, microcirculatory imaging, and more recently, quantitative and molecular imaging. In drug delivery and gene therapy, microbubbles are being investigated/developed as vehicles which can be loaded with the required therapeutic agent, traced to the target site using diagnostic ultrasound, and then destroyed with ultrasound of higher intensity energy burst to release the material locally, thus avoiding side effects associated with systemic administration, e.g. of toxic chemotherapy. It has moreover been shown that the motion of the microbubbles increases the permeability of both individual cell membranes and the endothelium, thus enhancing therapeutic uptake, and can locally increase the activity of drugs by enhancing their transport across biologically inaccessible interfaces such as blood clots or solid tumours. In high-intensity focused ultrasound (HIFU) surgery and lithotripsy, controlled cavitation is being investigated as a means of increasing the speed and efficacy of the treatment. The aim of this paper is both to describe the key features of the physical behaviour of acoustically driven bubbles which underlie their effectiveness in biomedical applications and to review the current state of the art.

  3. MFTF-B plasma-diagnostic system

    International Nuclear Information System (INIS)

    Throop, A.L.; Goerz, D.A.; Thomas, S.R.

    1981-01-01

    This paper describes the current design status of the plasma diagnostic system for MFTF-B. In this paper we describe the system requirement changes which have occurred as a result of the funded rescoping of the original MFTF facility into MFTF-B. We outline the diagnostic instruments which are currently planned, and present an overview of the diagnostic system

  4. Ultrasound elastography-based assessment of the elasticity of the supraspinatus muscle in impingement syndrome: does elastography has any diagnostic value?

    Science.gov (United States)

    Demirel, Adnan; Baykara, Murat; Koca, Tuba Tülay; Berk, Ejder

    2018-06-01

    Ultrasound elastography (UE) is a new ultrasound-based imaging technique that provides information about elasticity and stiffness of tissues. This cross-sectional study aimed to identify the diagnostic importance of UE in supraspinatus impingement syndrome. Forty-one subjects, aged 38-70 years, were included in the study. UE was used to determine the elasticity of the supraspinatus muscle. The strain ratio was calculated as the evaluation criteria to measure the elasticity of the muscle. High strain ratio indicated low elasticity. The measurements were made by the blinded radiologist while the patients sat with their shoulder in a neutral position. The diagnostic value of the strain ratio was evaluated using the receiver operating characteristic (ROC) analysis. The mean strain value of the supraspinatus muscle on the intact and pathological shoulders determined by UE was 0.74 ± 0.33 and 0.31 ± 0.24, respectively. A low strain ratio value in the supraspinatus muscle on the side with impingement syndrome was measured. When the test variable was evaluated as "strain ratio" according to ROC curve analysis, it was found to be above the reference line [0.849 (> 0.5)] (P = 0.00). When the cutoff value was selected as 0.495, the sensitivity and specificity were found to be 75.6 and 78% (the strain ratio value > 0.495), respectively. Measurement of strain ratio with UE can be used as a noninvasive, inexpensive, and practical diagnostic test for the shoulder impingement disease.

  5. High intensity focused ultrasound technology, its scope and applications in therapy and drug delivery.

    Science.gov (United States)

    Phenix, Christopher Peter; Togtema, Melissa; Pichardo, Samuel; Zehbe, Ingeborg; Curiel, Laura

    2014-01-01

    Ultrasonography is a safe, inexpensive and wide-spread diagnostic tool capable of producing real-time non-invasive images without significant biological effects. However, the propagation of higher energy, intensity and frequency ultrasound waves through living tissues can induce thermal, mechanical and chemical effects useful for a variety of therapeutic applications. With the recent development of clinically approved High Intensity Focused Ultrasound (HIFU) systems, therapeutic ultrasound is now a medical reality. Indeed, HIFU has been used for the thermal ablation of pathological lesions; localized, minimally invasive ultrasound-mediated drug delivery through the transient formation of pores on cell membranes; the temporary disruption of skin and the blood brain barrier; the ultrasound induced break-down of blood clots; and the targeted release of drugs using ultrasound and temperature sensitive drug carriers. This review seeks to engage the pharmaceutical research community by providing an overview on the biological effects of ultrasound as well as highlighting important therapeutic applications, current deficiencies and future directions.

  6. Ultrasound techniques in the evaluation of the mediastinum, part 2

    DEFF Research Database (Denmark)

    Jenssen, Christian; Annema, Jouke Tabe; Clementsen, Paul

    2015-01-01

    and inoperable lung cancer (e.g., surgery vs. combined chemoradiation therapy). Tissue sampling is often indicated for accurate nodal staging. Recent international lung cancer staging guidelines clearly state that endosonography should be the initial tissue sampling test over surgical staging. Mediastinal nodes...... can be sampled from the airways [endobronchial ultrasound combined with transbronchial needle aspiration (EBUS-TBNA)] or the esophagus [endoscopic ultrasound fine needle aspiration (EUS-FNA)]. EBUS and EUS have a complementary diagnostic yield and in combination virtually all MLNs can be biopsied...... and mediastinal staging of lung cancer. A specific emphasis will be on learning mediastinal endosonography. Part 1 deals with an introduction into ultrasound techniques, MLN anatomy and diagnostic reach of ultrasound techniques and part 2 with the clinical work up of neoplastic and inflammatory mediastinal...

  7. Real-Time Implementation of Medical Ultrasound Strain Imaging System

    International Nuclear Information System (INIS)

    Jeong, Mok Kun; Kwon, Sung Jae; Bae, Moo Ho

    2008-01-01

    Strain imaging in a medical ultrasound imaging system can differentiate the cancer or tumor in a lesion that is stiffer than the surrounding tissue. In this paper, a strain imaging technique using quasistatic compression is implemented that estimates the displacement between pre- and postcompression ultrasound echoes and obtains strain by differentiating it in the spatial direction. Displacements are computed from the phase difference of complex baseband signals obtained using their autocorrelation, and errors associated with converting the phase difference into time or distance are compensated for by taking into the center frequency variation. Also, to reduce the effect of operator's hand motion, the displacements of all scanlines are normalized with the result that satisfactory strain image quality has been obtained. These techniques have been incorporated into implementing a medical ultrasound strain imaging system that operates in real time.

  8. WE-D-18C-01: Art of Imaging: Diagnostic Ultrasound Image Artifacts

    Energy Technology Data Exchange (ETDEWEB)

    Zagzebski, J [University of Wisconsin, Madison, WI (United States); Lu, Z [University of Chicago, Chicago, IL (United States)

    2014-06-15

    Assumptions followed during construction of B-mode and color flow images are that the pulse-echo transit time can be converted to reflector depth through uniform tissue models, echoes originate only from locations along the transmit-receive axes of pulse propagation, and first order correction schemes adequately account for acoustic wave attenuation and absorption. The latter allows the display brightness to encode tissue echogenicity. This course will challenge participants to identify imaging artifacts whose origins stem from the more complex and realistic propagating and scattering conditions common in clinical ultrasound. Speckle, a very common artifact but a clinically employed feature, originates from simultaneous echoes from diffuse scatterers and is a result of coherent detection of signals. One of the most bothersome artifacts are those due to reverberations especially that originating from superficial tissue interfaces. Methods to overcome these will be discussed. This presentation also will describe and illustrate speed of sound, refraction, enhancement, shadowing, mirroring, beam width, beam-forming, and slice thickness artifacts. All are useful examples of limitations introduced by acoustic waves propagating through complex tissue paths. New formats for physician board certification exams are demanding the inclusion of image-based examples of ultrasound physics. Instructors' knowledge of, and access to examples of ultrasound artifacts are important in this effort. The presentation will incorporate an audience response system to challenge participants in correct identification of some of these artifacts. Learning Objectives: Review basic mechanisms for producing ultrasound images. Identify the etiology of speckle, reverberation noise, beam width and slice thickness artifacts, and artifacts associated with pulse propagation. Discuss methods that reduce the impact of artifacts OR employ artifacts effectively to facilitate clinical diagnosis.

  9. Ultrasound systems for blood velocity estimation

    DEFF Research Database (Denmark)

    Jensen, Jørgen Arendt

    1998-01-01

    Medical ultrasound scanners can be used both for displayinggray-scale images of the anatomy and for visualizing theblood flow dynamically in the body.The systems can interrogate the flow at a single position in the bodyand there find the velocity distribution over time. They can also show adynamic...

  10. Diagnostic accuracy of percutaneous cytodiagnosis of hepatic masses, by ultrasound guided fine needle aspiration cytology

    International Nuclear Information System (INIS)

    Asghar, F.; Riaz, S.

    2010-01-01

    Objective: To evaluate the diagnostic accuracy, usefulness and limitations of ultrasound guided FNAC of hepatic masses. Design: Cross - sectional analytical (comparative study). Place and Duration: Department of histopathology, Sheikh Zayed Hospital, Lahore. Study period 1 year. Material and Methods: A total of 32 patients with solitary or multiple hepatic masses underwent FNAC from March 1999 to March 2000. Adequate aspirates were obtained in all these cases. Smears were stained with May-Grunwald Giemsa, Haematoxylin and Eosin and Papanicolaou stain. Needle biopsies from the same cases were also obtained and processed. These were stained with routine Haematoxylin and Eosin staining. The blood clots obtained during FNAC were fixed in 10% neu-tral buffered formalin. The histopathology of these blood clots was used for cases whose needle core biopsy was not available. The screened FNAC smears were divided into 3 categories i.e., benign (group - I), malignant (group - II), non-neoplastic / inflammatory lesions (including cysts and abscesses) (group - III). Results: Out of 32 cases, 6 were categorized as benign, 18 as malignant, and 8 as non-neoplastic inflammatory lesions. Three false negative diagnoses, including 1 for malignant tumour and 2 for benign tumours was obtained. There was 1 false positive diagnosis for malignancy. FNAC - histological correlation showed a 94.2% sensitivity and 92.3% diagnostic accuracy for malignant tumours, while benign tumours posed maximum diagnostic problems, giving a 66.67% sensitivity and 85.7% diagnostic accuracy. FNAC picked up correctly all the non-neoplastic lesions giving a 100% sensitivity and diagnostic accuracy. Conclusion: Majority of the malignant tumours can be categorized on FNAC, with a high degree of accuracy, while benign tumours should be subjected to biopsy, as there is a relatively greater possibility of false negative diagnosis. (author)

  11. Characterization of controlled bone defects using 2D and 3D ultrasound imaging techniques

    Energy Technology Data Exchange (ETDEWEB)

    Parmar, Biren J; Longsine, Whitney; Han, Arum; Righetti, Raffaella [Department of Electrical and Computer Engineering, Dwight Look College of Engineering, Texas A and M University, College Station, TX (United States); Sabonghy, Eric P [OneOrtho Orthopedic Surgery Clinic, Houston, TX (United States); Tasciotti, Ennio; Ferrari, Mauro [Department of Nanomedicine and Biomedical Engineering, University of Texas Health Science Center at Houston, Houston, TX (United States); Weiner, Bradley K, E-mail: righetti@ece.tamu.ed [Division of Spinal Surgery, Department of Orthopaedic Surgery, Methodist Hospital, Houston, TX 77030 (United States)

    2010-08-21

    Ultrasound is emerging as an attractive alternative modality to standard x-ray and CT methods for bone assessment applications. As of today, however, there is a lack of systematic studies that investigate the performance of diagnostic ultrasound techniques in bone imaging applications. This study aims at understanding the performance limitations of new ultrasound techniques for imaging bones in controlled experiments in vitro. Experiments are performed on samples of mammalian and non-mammalian bones with controlled defects with size ranging from 400 {mu}m to 5 mm. Ultrasound findings are statistically compared with those obtained from the same samples using standard x-ray imaging modalities and optical microscopy. The results of this study demonstrate that it is feasible to use diagnostic ultrasound imaging techniques to assess sub-millimeter bone defects in real time and with high accuracy and precision. These results also demonstrate that ultrasound imaging techniques perform comparably better than x-ray imaging and optical imaging methods, in the assessment of a wide range of controlled defects both in mammalian and non-mammalian bones. In the future, ultrasound imaging techniques might provide a cost-effective, real-time, safe and portable diagnostic tool for bone imaging applications.

  12. "Anterior convergent" chest probing in rapid ultrasound transducer positioning versus formal chest ultrasonography to detect pneumothorax during the primary survey of hospital trauma patients: a diagnostic accuracy study.

    Science.gov (United States)

    Ziapour, Behrad; Haji, Houman Seyedjavady

    2015-01-01

    Occult pneumothorax represents a diagnostic pitfall during the primary survey of trauma patients, particularly if these patients require early positive pressure ventilation. This study investigated the accuracy of our proposed rapid model of ultrasound transducer positioning during the primary survey of trauma patients after their arrival at the hospital. This diagnostic trial was conducted over 12 months and was based on the results of 84 ultrasound (US) exams performed on patients with severe multiple trauma. Our index test (US) was used to detect pneumothorax in four pre-defined locations on the anterior of each hemi-thorax using the "Anterior Convergent" approach, and its performance was limited to the primary survey. Consecutively, patients underwent chest-computed tomography (CT) with or without chest radiography. The diagnostic findings of both chest radiography and chest ultrasounds were compared to the gold-standard test (CT). The diagnostic sensitivity was 78 % for US and 36.4 % for chest radiography (p chest radiography (not significant); the positive predictive values were 74 % for US and 80 % for chest radiography (not significant); the negative predictive values were 94 % for US and 87 % for chest radiography (not significant); the positive likelihood ratio was 10 for US and 18 for chest radiography (p = 0.007); and the negative likelihood ratio was 0.25 for US and 0.65 for chest radiography (p = 0.001). The mean required time for performing the new method was 64 ± 10 s. An absence of the expected diffused dynamic view among ultrasound images obtained from patients with pneumothorax was also observed. We designated this phenomenon "Gestalt Lung Recession." "Anterior convergent" chest US probing represents a brief but efficient model that provides clinicians a safe and accurate exam and adequate resuscitation during critical minutes of the primary survey without interrupting other medical staff activities taking place around the

  13. The Role of Airway and Endobronchial Ultrasound in Perioperative Medicine

    Directory of Open Access Journals (Sweden)

    Jiri Votruba

    2015-01-01

    Full Text Available Recent years have witnessed an increased use of ultrasound in evaluation of the airway and the lower parts of the respiratory system. Ultrasound examination is fast and reliable and can be performed at the bedside and does not carry the risk of exposure to ionizing radiation. Apart from use in diagnostics it may also provide safe guidance for invasive and semi-invasive procedures. Ultrasound examination of the oral cavity structures, epiglottis, vocal cords, and subglottic space may help in the prediction of difficult intubation. Preoperative ultrasound may diagnose vocal cord palsy or deviation or stenosis of the trachea. Ultrasonography can also be used for confirmation of endotracheal tube, double-lumen tube, or laryngeal mask placement. This can be achieved by direct examination of the tube inside the trachea or by indirect methods evaluating lung movements. Postoperative airway ultrasound may reveal laryngeal pathology or subglottic oedema. Conventional ultrasound is a reliable real-time navigational tool for emergency cricothyrotomy or percutaneous dilational tracheostomy. Endobronchial ultrasound is a combination of bronchoscopy and ultrasonography and is used for preoperative examination of lung cancer and solitary pulmonary nodules. The method is also useful for real-time navigated biopsies of such pathological structures.

  14. The Use of Enteric Contrast Media for Diagnostic CT, MRI, and Ultrasound in Infants and Children: A Practical Approach.

    Science.gov (United States)

    Callahan, Michael J; Talmadge, Jennifer M; MacDougall, Robert; Buonomo, Carlo; Taylor, George A

    2016-05-01

    Enteric contrast media are commonly administered for diagnostic cross-sectional imaging studies in the pediatric population. The purpose of this manuscript is to review the use of enteric contrast media for CT, MRI, and ultrasound in infants, children, and adolescents and to share our experiences at a large tertiary care pediatric teaching hospital. The use of enteric contrast material for diagnostic imaging in infants and children continues to evolve with advances in imaging technology and available enteric contrast media. Many principles of enteric contrast use in pediatric imaging are similar to those in adult imaging, but important differences must be kept in mind when imaging the gastrointestinal tract in infants and children, and practical ways to optimize the imaging examination and the patient experience should be employed where possible.

  15. A Computer-Aided Diagnosis System Using Artificial Intelligence for the Diagnosis and Characterization of Thyroid Nodules on Ultrasound: Initial Clinical Assessment.

    Science.gov (United States)

    Choi, Young Jun; Baek, Jung Hwan; Park, Hye Sun; Shim, Woo Hyun; Kim, Tae Yong; Shong, Young Kee; Lee, Jeong Hyun

    2017-04-01

    An initial clinical assessment is described of a new, commercially available, computer-aided diagnosis (CAD) system using artificial intelligence (AI) for thyroid ultrasound, and its performance is evaluated in the diagnosis of malignant thyroid nodules and categorization of nodule characteristics. Patients with thyroid nodules with decisive diagnosis, whether benign or malignant, were consecutively enrolled from November 2015 to February 2016. An experienced radiologist reviewed the ultrasound image characteristics of the thyroid nodules, while another radiologist assessed the same thyroid nodules using the CAD system, providing ultrasound characteristics and a diagnosis of whether nodules were benign or malignant. The diagnostic performance and agreement of US characteristics between the experienced radiologist and the CAD system were compared. In total, 102 thyroid nodules from 89 patients were included; 59 (57.8%) were benign and 43 (42.2%) were malignant. The CAD system showed a similar sensitivity as the experienced radiologist (90.7% vs. 88.4%, p > 0.99), but a lower specificity and a lower area under the receiver operating characteristic (AUROC) curve (specificity: 74.6% vs. 94.9%, p = 0.002; AUROC: 0.83 vs. 0.92, p = 0.021). Classifications of the ultrasound characteristics (composition, orientation, echogenicity, and spongiform) between radiologist and CAD system were in substantial agreement (κ = 0.659, 0.740, 0.733, and 0.658, respectively), while the margin showed a fair agreement (κ = 0.239). The sensitivity of the CAD system using AI for malignant thyroid nodules was as good as that of the experienced radiologist, while specificity and accuracy were lower than those of the experienced radiologist. The CAD system showed an acceptable agreement with the experienced radiologist for characterization of thyroid nodules.

  16. Evolution of contrast agents for ultrasound imaging and ultrasound-mediated drug delivery

    Directory of Open Access Journals (Sweden)

    Vera ePaefgen

    2015-09-01

    Full Text Available Ultrasound is one of the most frequently used diagnostic methods. It is a non-invasive, comparably inexpensive imaging method with a broad spectrum of applications, which can be increased even more by using bubbles as contrast agents. There are various different types of bubbles: filled with different gases, composed of soft- or hard-shell materials, and ranging in size from nano- to micrometers. These intravascular contrast agents enable functional analyses, e.g. to acquire organ perfusion in real-time. Molecular analyses are achieved by coupling specific ligands to the bubbles’ shell, which bind to marker molecules in the area of interest. Bubbles can also be loaded with or attached to drugs, peptides or genes and can be destroyed by ultrasound pulses to locally release the entrapped agent. Recent studies show that ultrasound contrast agents are also valuable tools in hyperthermia-induced ablation therapy of tumors, or can increase cellular uptake of locally released drugs by enhancing membrane permeability. This review summarizes important steps in the development of ultrasound contrast agents and introduces the current clinical applications of contrast-enhanced ultrasound. Additionally, an overview of the recent developments in ultrasound probe design for functional and molecular diagnosis as well as for drug delivery is given.

  17. Endobronchial Ultrasound (EBUS) - Update 2017.

    Science.gov (United States)

    Darwiche, Kaid; Özkan, Filiz; Wolters, Celina; Eisenmann, Stephan

    2018-02-01

    Endobronchial ultrasound (EBUS) has revolutionized the diagnosis of lung cancer over the last decade. This minimally invasive diagnostic method has also become increasingly important in the case of other diseases such as sarcoidosis, thereby helping to avoid unnecessary diagnostic interventions. This review article provides an update regarding EBUS and discusses current and future developments of this method. © Georg Thieme Verlag KG Stuttgart · New York.

  18. A contrast-enhanced ultrasound study of benign and malignant ...

    African Journals Online (AJOL)

    A contrast-enhanced ultrasound study of benign and malignant breast tissue. S Barnard, E Leen, T Cooke, W Angerson. Abstract. Objective. To determine the diagnostic value of haemodynamic contrast-enhanced ultrasound assessment in benign and malignant breast tissue, using histological examination as the reference ...

  19. Strain ratio ultrasound elastography increases the accuracy of colour-Doppler ultrasound in the evaluation of Thy-3 nodules. A bi-centre university experience.

    Science.gov (United States)

    Cantisani, Vito; Maceroni, Piero; D'Andrea, Vito; Patrizi, Gregorio; Di Segni, Mattia; De Vito, Corrado; Grazhdani, Hektor; Isidori, Andrea M; Giannetta, Elisa; Redler, Adriano; Frattaroli, Fabrizio; Giacomelli, Laura; Di Rocco, Giorgio; Catalano, Carlo; D'Ambrosio, Ferdinando

    2016-05-01

    To assess whether ultrasound elastography (USE) with strain ratio increases diagnostic accuracy of Doppler ultrasound in further characterisation of cytologically Thy3 thyroid nodules. In two different university diagnostic centres, 315 patients with indeterminate cytology (Thy3) in thyroid nodules aspirates were prospectively evaluated with Doppler ultrasound and strain ratio USE before surgery. Ultrasonographic features were analysed separately and together as ultrasound score, to assess sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV). Receiver operating characteristic (ROC) curves to identify optimal cut-off value of the strain ratio were also provided. Diagnosis on a surgical specimen was considered the standard of reference. Higher strain ratio values were found in malignant nodules, with an optimum strain ratio cut-off of 2.09 at ROC analysis. USE with strain ratio showed 90.6% sensitivity, 93% specificity, 82.8% PPV, 96.4% NPV, while US score yielded a sensitivity of 52.9%, specificity of 84.3%, PPV 55.6% and NPV 82.9%. The diagnostic gain with strain ratio was statistically significant as proved by ROC areas, which was 0.9182 for strain ratio and 0.6864 for US score. USE with strain ratio should be considered a useful additional tool to colour-Doppler US, since it improves characterisation of thyroid nodules with indeterminate cytology. • Strain ratio measurements improve differentiation of thyroid nodules with indeterminate cytology • Elastography with strain ratio is more reliable than ultrasound features and ultrasound score • Strain ratio may help to better select patients with Thy 3 nodules candidate for surgery.

  20. Holistic ultrasound in trauma: An update.

    Science.gov (United States)

    Saranteas, Theodosios; Mavrogenis, Andreas F

    2016-10-01

    Holistic ultrasound is a total body examination using an ultrasound device aiming to achieve immediate patient care and decision making. In the setting of trauma, it is one of the most fundamental components of care of the injured patients. Ground-breaking imaging software allows physicians to examine various organs thoroughly, recognize imaging signs early, and potentially foresee the onset or the possible outcome of certain types of injuries. Holistic ultrasound can be performed on a routine basis at the bedside of the patients, at admission and during the perioperative period. Trauma care physicians should be aware of the diagnostic and guidance benefits of ultrasound and should receive appropriate training for the optimal management of their patients. In this paper, the findings of holistic ultrasound in trauma patients are presented, with emphasis on the lungs, heart, cerebral circulation, abdomen, and airway. Additionally, the benefits of ultrasound imaging in interventional anaesthesia techniques such as ultrasound-guided peripheral nerve blocks and central vein catheterization are described. Copyright © 2016 Elsevier Ltd. All rights reserved.

  1. Evaluation of the diagnostic accuracy of ultra-miniaturized pocket ultrasound device on cardiac function in critically ill patients

    Directory of Open Access Journals (Sweden)

    Li WANG

    2016-09-01

    Full Text Available Objective  To compare the diagnostic accuracy of a new ultra-miniaturized pocket ultrasound device (PUD (VscanTM, GE Healthcare, Wauwatosa, WI and conventional high-quality echocardiography system (Vivid qTM, GE Healthcare for a cardiac focused ultrasonography in critical patients. Methods  The patients admitted to our hospital and receiving transthoracic echocardiography (TTE using a PUD and a conventional echocardiography system were included in this study during the 10 months from December 2013 to October 2014. Each examination was performed independently by an intensive care unit (ICU physician and an experienced ultrasound doctor, unaware of the results found by the alternative device. The following parameters were assessed: global cardiac systolic function, identification of ventricular size, whether or not accompanying enlargement or hypertrophy, assessment for the morphology of cardiac valves and its function, pericardial effusion and estimation of the inferior vena cava (IVC diameter. The time-consuming of each device were recorded. Results  One hundred and twenty-eight patients were included in the study. Their left ventricular wall motion abnormalities, global left ventricular systolic dysfunction, pericardial effusion, IVC dilation were assessed by PUD and the assessment results were highly consistent with those by Vivid q (κ>0.84. The consistency was slightly lower in evaluating the left and right ventricular size. For evaluating the cardiac valves function, the agreement of two devices were relatively low (κ=0.69-0.84. Compared with Vivid q, PUD took less time (4.7±1.4min vs 6.3±2.6min; P<0.05. Conclusion  PUD can provide fast, reliable cardiac examination, thus being an effective method for ICU physicians to assess the cardiac f unction in critical patients. DOI: 10.11855/j.issn.0577-7402.2016.08.10

  2. Development and implementation of ultrasound picture archiving and communication system

    Science.gov (United States)

    Weinberg, Wolfram S.; Tessler, Franklin N.; Grant, Edward G.; Kangarloo, Hooshang; Huang, H. K.

    1990-08-01

    The Department of Radiological Sciences at the UCLA School of Medicine is developing an archiving and communication system (PACS) for digitized ultrasound images. In its final stage the system will involve the acquisition and archiving of ultrasound studies from four different locations including the Center for Health Sciences, the Department for Mental Health and the Outpatient Radiology and Endoscopy Departments with a total of 200-250 patient studies per week. The concept comprises two stages of image manipulation for each ultrasound work area. The first station is located close to the examination site and accomodates the acquisition of digital images from up to five ultrasound devices and provides for instantaneous display and primary viewing and image selection. Completed patient studies are transferred to a main workstation for secondary review, further analysis and comparison studies. The review station has an on-line storage capacity of 10,000 images with a resolution of 512x512 8 bit data to allow for immediate retrieval of active patient studies of up to two weeks. The main work stations are connected through the general network and use one central archive for long term storage and a film printer for hardcopy output. First phase development efforts concentrate on the implementation and testing of a system at one location consisting of a number of ultrasound units with video digitizer and network interfaces and a microcomputer workstation as host for the display station with two color monitors, each allowing simultaneous display of four 512x512 images. The discussion emphasizes functionality, performance and acceptance of the system in the clinical environment.

  3. ITER diagnostic system: Vacuum interface

    Energy Technology Data Exchange (ETDEWEB)

    Patel, K.M., E-mail: Kaushal.Patel@iter.org [ITER Organization, Route de Vinon sur Verdon, 13115 St Paul-Lez-Durance (France); Udintsev, V.S.; Hughes, S.; Walker, C.I.; Andrew, P.; Barnsley, R.; Bertalot, L. [ITER Organization, Route de Vinon sur Verdon, 13115 St Paul-Lez-Durance (France); Drevon, J.M. [Bertin Technologies, BP 22, 13762 Aix-en Provence cedex 3 (France); Encheva, A. [ITER Organization, Route de Vinon sur Verdon, 13115 St Paul-Lez-Durance (France); Kashchuk, Y. [Institution “PROJECT CENTER ITER”, 1, Akademika Kurchatova pl., Moscow (Russian Federation); Maquet, Ph. [Bertin Technologies, BP 22, 13762 Aix-en Provence cedex 3 (France); Pearce, R.; Taylor, N.; Vayakis, G.; Walsh, M.J. [ITER Organization, Route de Vinon sur Verdon, 13115 St Paul-Lez-Durance (France)

    2013-10-15

    Diagnostics play an essential role for the successful operation of the ITER tokamak. They provide the means to observe control and to measure plasma during the operation of ITER tokamak. The components of the diagnostic system in the ITER tokamak will be installed in the vacuum vessel, in the cryostat, in the upper, equatorial and divertor ports, in the divertor cassettes and racks, as well as in various buildings. Diagnostic components that are placed in a high radiation environment are expected to operate for the life of ITER. There are approx. 45 diagnostic systems located on ITER. Some diagnostics incorporate direct or independently pumped extensions to maintain their necessary vacuum conditions. They require a base pressure less than 10{sup −7} Pa, irrespective of plasma operation, and a leak rate of less than 10{sup −10} Pa m{sup 3} s{sup −1}. In all the cases it is essential to maintain the ITER closed fuel cycle. These directly coupled diagnostic systems are an integral part of the ITER vacuum containment and are therefore subject to the same design requirements for tritium and active gas confinement, for all normal and accidental conditions. All the diagnostics, whether or not pumped, incorporate penetration of the vacuum boundary (i.e. window assembly, vacuum feedthrough etc.) and demountable joints. Monitored guard volumes are provided for all elements of the vacuum boundary that are judged to be vulnerable by virtue of their construction, material, load specification etc. Standard arrangements are made for their construction and for the monitoring, evacuating and leak testing of these volumes. Diagnostic systems are incorporated at more than 20 ports on ITER. This paper will describe typical and particular arrangements of pumped diagnostic and monitored guard volume. The status of the diagnostic vacuum systems, which are at the start of their detailed design, will be outlined and the specific features of the vacuum systems in ports and extensions

  4. ITER diagnostic system: Vacuum interface

    International Nuclear Information System (INIS)

    Patel, K.M.; Udintsev, V.S.; Hughes, S.; Walker, C.I.; Andrew, P.; Barnsley, R.; Bertalot, L.; Drevon, J.M.; Encheva, A.; Kashchuk, Y.; Maquet, Ph.; Pearce, R.; Taylor, N.; Vayakis, G.; Walsh, M.J.

    2013-01-01

    Diagnostics play an essential role for the successful operation of the ITER tokamak. They provide the means to observe control and to measure plasma during the operation of ITER tokamak. The components of the diagnostic system in the ITER tokamak will be installed in the vacuum vessel, in the cryostat, in the upper, equatorial and divertor ports, in the divertor cassettes and racks, as well as in various buildings. Diagnostic components that are placed in a high radiation environment are expected to operate for the life of ITER. There are approx. 45 diagnostic systems located on ITER. Some diagnostics incorporate direct or independently pumped extensions to maintain their necessary vacuum conditions. They require a base pressure less than 10 −7 Pa, irrespective of plasma operation, and a leak rate of less than 10 −10 Pa m 3 s −1 . In all the cases it is essential to maintain the ITER closed fuel cycle. These directly coupled diagnostic systems are an integral part of the ITER vacuum containment and are therefore subject to the same design requirements for tritium and active gas confinement, for all normal and accidental conditions. All the diagnostics, whether or not pumped, incorporate penetration of the vacuum boundary (i.e. window assembly, vacuum feedthrough etc.) and demountable joints. Monitored guard volumes are provided for all elements of the vacuum boundary that are judged to be vulnerable by virtue of their construction, material, load specification etc. Standard arrangements are made for their construction and for the monitoring, evacuating and leak testing of these volumes. Diagnostic systems are incorporated at more than 20 ports on ITER. This paper will describe typical and particular arrangements of pumped diagnostic and monitored guard volume. The status of the diagnostic vacuum systems, which are at the start of their detailed design, will be outlined and the specific features of the vacuum systems in ports and extensions will be described

  5. Diagnostic accuracy of commercial system for computer-assisted detection (CADx) as an adjunct to interpretation of mammograms

    International Nuclear Information System (INIS)

    Menna, Sabatino; Di Virgilio, Maria Rosaria; Burke, Paolo; Frigerio, Alfonso; Boglione, Elisa; Ciccarelli, Grazia; Di Filippo, Sabato; Garretti, Licia

    2005-01-01

    Purpose. To evaluate the diagnostic accuracy of the commercial computer-aided detection CADx system for the reading of mammograms. Materials and methods. The study assessed the Second Look system developed and marketed by CADx Medical Systems, Montreal, Canada. The diagnostic sensitivity was evaluated by means of a retrospective study on 98 consecutive cancers detected at screening by double independent reading. The specificity and the positive predictive value (PPV) for cancer of the CADx system were prospectively evaluated on a second group of 560 consecutive mammograms of asymptomatic women not included in screening program. The radiologist who was present during the test assessed the abnormal mammographic findings by one or more of the following diagnostic procedures: physical examination, additional mammographic detail views with or without magnification,ultrasonography, ultrasound- or mammography guided fine needle aspiration cytology, and core-biopsy. The exams first underwent conventional reading and then a second reading carried out with the aid of the CADx system. Results.The overall diagnostic sensitivity of the CADx system on the 98 screening cancers was 81.6%; in particular it was 89.3% for calcifications, 83.9% for masses and only 37.5% for architectural distortion. The CADx markings for each mammography were 4.7 on average. Identification of invasive carcinoma was independent from tumour size. In the second group of 560 mammograms, the CADx system marked all cases identified as positive by conventional reading and confirmed by biopsy (7/7), but did not permit the detection of any additional cancer. The CADx markings per exam were 4.2 on average, the specificity was 13.7% and the PPV was 0.55% versus 13.7% recall rate of conventional reading. CADx reading led to a 1.96% (11/560) increase of the women necessitating further diagnostic investigation. Conclusions. The results of our study show that the diagnostic sensitivity of the CADx system is lower

  6. Indeterminate solid hepatic lesions identified on non-diagnostic contrast-enhanced computed tomography: Assessment of the additional diagnostic value of contrast-enhanced ultrasound in the non-cirrhotic liver

    International Nuclear Information System (INIS)

    Quaia, Emilio; De Paoli, Luca; Angileri, Roberta; Cabibbo, Biagio; Cova, Maria Assunta

    2014-01-01

    Objective: To assess the additional diagnostic value of contrast-enhanced ultrasound (CEUS) in the characterization of indeterminate solid hepatic lesions identified on non-diagnostic contrast-enhanced computed tomography (CT). Methods: Fifty-five solid hepatic lesions (1–4 cm in diameter) in 46 non-cirrhotic patients (26 female, 20 male; age ± SD, 55 ± 10 years) underwent CEUS after being detected on contrast-enhanced CT which was considered as non-diagnostic after on-site analysis. Two blinded independent readers assessed CT and CEUS scans and were asked to classify retrospectively each lesion as a malignant or benign based on reference diagnostic criteria for the different hepatic lesion histotypes. Diagnostic accuracy and confidence (area – A z – under ROC curve) were assessed by using gadobenate dimeglumine-enhanced magnetic resonance (MR) imaging (n = 30 lesions), histology (n = 7 lesions), or US follow-up (n = 18 lesions) as the reference standards. Results: Final diagnoses included 29 hemangiomas, 3 focal nodular hyperplasias, 1 hepatocellular adenoma, and 22 metastases. The additional review of CEUS after CT images improved significantly (P < .05) the diagnostic accuracy (before vs after CEUS review = 49% [20/55] vs 89% [49/55] – reader 1 and 43% [24/55] vs 92% [51/55] – reader 2) and confidence (A z , 95% Confidence Intervals before vs after CEUS review = .773 [.652–.895] vs .997 [.987–1] – reader 1 and .831 [.724–.938] vs .998 [.992–1] – reader 2). Conclusions: CEUS improved the characterization of indeterminate solid hepatic lesions identified on non-diagnostic contrast-enhanced CT by identifying some specific contrast enhancement patterns.

  7. The Maastricht Ultrasound Shoulder pain trial (MUST: Ultrasound imaging as a diagnostic triage tool to improve management of patients with non-chronic shoulder pain in primary care

    Directory of Open Access Journals (Sweden)

    Cals Jochen WL

    2011-07-01

    Full Text Available Abstract Background Subacromial disorders are considered to be one of the most common pathologies affecting the shoulder. Optimal therapy for shoulder pain (SP in primary care is yet unknown, since clinical history and physical examination do not provide decisive evidence as to the patho-anatomical origin of the symptoms. Optimal decision strategies can be furthered by applying ultrasound imaging (US, an accurate method in diagnosing SP, demonstrating a clear relationship between diagnosis and available therapies. Yet, the clinical cost-effectiveness of applying US in the management of SP in primary care has not been studied. The aim of this paper is to describe the design and methods of a trial assessing the cost-effectiveness of ultrasound imaging as a diagnostic triage tool to improve management of primary care patients with non-chronic shoulder pain. Methods/Design This randomised controlled trial (RCT will involve 226 adult patients with suspected subacromial disorders recruited by general practitioners. During a Qualification period of two weeks, patients receive care as usual as advised by the Dutch College of General Practitioners, and patients are referred for US. Patients with insufficient improvement qualify for the RCT. These patients are then randomly assigned to the intervention or the control group. The therapies used in both groups are the same (corticosteroid injections, referral to a physiotherapist or orthopedic surgeon except that therapies used in the intervention group will be tailored based on the US results. Ultrasound diagnosed disorders include tendinopathy, calcific tendinitis, partial and full thickness tears, and subacromial bursitis. The primary outcome is patient-perceived recovery at 52 weeks, using the Global Perceived Effect questionnaire. Secondary outcomes are disease specific and generic quality of life, cost-effectiveness, and the adherence to the initial applied treatment. Outcome measures will be assessed

  8. Hybrid Photoacoustic/Ultrasound Tomograph for Real-Time Finger Imaging.

    Science.gov (United States)

    Oeri, Milan; Bost, Wolfgang; Sénégond, Nicolas; Tretbar, Steffen; Fournelle, Marc

    2017-10-01

    We report a target-enclosing, hybrid tomograph with a total of 768 elements based on capacitive micromachined ultrasound transducer technology and providing fast, high-resolution 2-D/3-D photoacoustic and ultrasound tomography tailored to finger imaging. A freely programmable ultrasound beamforming platform sampling data at 80 MHz was developed to realize plane wave transmission under multiple angles. A multiplexing unit enables the connection and control of a large number of elements. Fast image reconstruction is provided by GPU processing. The tomograph is composed of four independent and fully automated movable arc-shaped transducers, allowing imaging of all three finger joints. The system benefits from photoacoustics, yielding high optical contrast and enabling visualization of finger vascularization, and ultrasound provides morphologic information on joints and surrounding tissue. A diode-pumped, Q-switched Nd:YAG laser and an optical parametric oscillator are used to broaden the spectrum of emitted wavelengths to provide multispectral imaging. Custom-made optical fiber bundles enable illumination of the region of interest in the plane of acoustic detection. Precision in positioning of the probe in motion is ensured by use of a motor-driven guide slide. The current position of the probe is encoded by the stage and used to relate ultrasound and photoacoustic signals to the corresponding region of interest of the suspicious finger joint. The system is characterized in phantoms and a healthy human finger in vivo. The results obtained promise to provide new opportunities in finger diagnostics and establish photoacoustic/ultrasound-tomography in medical routine. Copyright © 2017 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  9. Ultrasound diagnosis and evaluation of plantar heel pain.

    Science.gov (United States)

    Argerakis, Nicholas G; Positano, Rock G; Positano, Rock C J; Boccio, Ashley K; Adler, Ronald S; Saboeiro, Gregory R; Dines, Joshua S

    2015-03-01

    One of the most common causes of heel pain is plantar fasciitis; however, there are other pathologic disorders that can mimic the symptoms and clinical presentation of this disorder. The purpose of this study was to retrospectively review the prevalence of various pathologic disorders on ultrasound in patients with proximal plantar heel pain. The medical records and diagnostic ultrasound reports of patients presenting with plantar heel pain between March 1, 2006, and March 31, 2007, were reviewed retrospectively, and the prevalence of various etiologies was collected. The inclusion criteria were based on their clinical presentation of plantar fasciitis or previous diagnosis of plantar fasciitis from an unknown source. Ultrasound evaluation was then performed to confirm the clinical diagnosis. We examined 175 feet of 143 patients (62 males and 81 females; age range, 16-79 years). Plantar fibromas were present in 90 feet (51%). Plantar fasciitis was diagnosed in 128 feet (73%). Coexistent plantar fibroma and plantar fascial thickening was found in 63 feet (36%). Of the 47 feet that were negative for plantar fasciitis on ultrasound, 27 (57%) revealed the presence of plantar fibroma. Diagnostic ultrasound can effectively and safely identify the prevalence of various etiologies of heel pain. The high prevalence of plantar fibromas and plantar fascial tears cannot be determined by clinical examination alone, and, therefore, ultrasound evaluation should be performed for confirmation of diagnosis.

  10. [Endobronchial Ultrasound (EBUS) - an Update 2017].

    Science.gov (United States)

    Darwiche, K; Özkan, F; Wolters, C; Eisenmann, S

    2017-11-01

    Endobronchial Ultrasound (EBUS) with the two modalities curved and radial EBUS significantly improved the diagnostics in several pulmonary diseases. The examination and staging of mediastinal and hilar lymph nodes in patients with known or suspected lung malignancy as well as the evaluation of unknown pulmonary or mediastinal lesions can be achieved with minimal invasive means when using EBUS. More invasive surgical procedures for diagnostic purposes can be omitted. The diagnostic yield also increases when EBUS is applied in sarcoidosis or mediastinal lymph node tuberculosis but only to some extend in case of lymphoma. Samples obtained by EBUS-TBNA should be handled efficiently to allow molecular analysis in lung cancer. EBUS is a safe procedure, and complication rate is extremely low. Further advances of the EBUS technology focus on improving analysis of the information provided by the ultrasound image and a better tissue sampling by developing of new EBUS bronchoscopes and TBNA-needles. © Georg Thieme Verlag KG Stuttgart · New York.

  11. Indications for and comparative diagnostic value of combined ultrasound and X-ray mammography

    International Nuclear Information System (INIS)

    Novak, D.

    1983-01-01

    A standardised method of ultrasound mammography is described. In order to achieve the same position, form, and shape of the breast as during roentgen mammography a Lucite plate in horizontal, and vertical position us used. Ultrasound contact scanning of the whole breast is carried out in cranio-caudal as well as in medio-lateral direction of the ultrasound beam. Ultrasound scanning is performed with the compression of the breast corresponding to the compression during roentgen mammography. It was found that the ultrasound breast examination combined with X-ray mammography optimizes the differentiation between benign and malignant masses and therefore may reduce the incidence of breast biopsy. A combined use of both examination modalities in the evaluation of the breast is advocated. (orig.)

  12. System Architecture of an Experimental Synthetic Aperture Real-Time Ultrasound System

    DEFF Research Database (Denmark)

    Jensen, Jørgen Arendt; Hansen, Martin; Tomov, Borislav Gueorguiev

    2007-01-01

    is done using a parametric beam former. Code synthesized for a Xilinx V4FX100 speed grade 11 FPGA can operate at a maximum clock frequency of 167.8 MHz producing 1 billion I and Q samples/second sufficient for real time SA imaging. The system is currently in production, and all boards have been laid out......Synthetic Aperture (SA) ultrasound imaging has many advantages in terms of flexibility and accuracy. One of the major drawbacks is, however, that no system exists, which can implement SA imaging in real time due to the very high number of calculations amounting to roughly 1 billion complex focused...... samples per second per receive channel. Real time imaging is a key aspect in ultrasound, and to truly demonstrate the many advantages of SA imaging, a system usable in the clinic should be made. The paper describes a system capable of real time SA B-mode and vector flow imaging. The Synthetic Aperture...

  13. Obstetrical ultrasound

    International Nuclear Information System (INIS)

    Bundy, A.L.

    1988-01-01

    The use of diagnostic ultrasound in obstetrics may provide fuel for legal action. While most legal implications of this relatively new imaging modality are purely speculative, some have already given rise to legal action. Several situations will likely provide a basis for the courts to find against the physician. The failure to perform a sonogram when clinically indicated will most likely be the strongest plaintiff argument. Other major concerns include the use and availability of state-of-the-art equipment, as well as interpretation of the scans by a trained physician. Obstetrical ultrasound is usually performed by a radiologist or obstetrician. However, many physicians performing these examinations have had little or no formal training in the field. While this is now being remedied by the respective board examines who require a certain amount of training, it may not be enough. When ultrasound-related cases reach the courts, the involved physicians will most likely be regarded as experts in the field and, therefore, will be held to a very high standard of care. This would be difficult to achieve without formal training. At the present time, the American Board of Radiology requires more training time in ultrasound than the American Board of Obstetrics and Gynecology

  14. Point-of-care ultrasound in aerospace medicine: known and potential applications.

    Science.gov (United States)

    Wagner, Michael S; Garcia, Kathleen; Martin, David S

    2014-07-01

    Since its initial introduction into the bedside assessment of the trauma patient via the Focused Assessment with Sonography for Trauma (FAST) exam, the use of point-of-care ultrasound has expanded rapidly. A growing body of literature demonstrates ultrasound can be used by nonradiologists as an extension of the physical exam to accurately diagnose or exclude a variety of conditions. These conditions include, but are not limited to, hemoperitoneum, pneumothorax, pulmonary edema, long-bone fracture, deep vein thrombosis, and elevated intracranial pressure. As ultrasound machines have become more compact and portable, their use has extended outside of hospitals to places where the physical exam and diagnostic capabilities may be limited, including the aviation environment. A number of studies using focused sonography have been performed to meet the diagnostic challenges of space medicine. The following article reviews the available literature on portable ultrasound use in aerospace medicine and highlights both known and potential applications of point-of-care ultrasound for the aeromedical clinician.

  15. Percutaneous antegrade pyelgraphy guided by ultrasound

    International Nuclear Information System (INIS)

    Kim, Jin Gyoo; Chung, Chun Phil; Lee, Suk Hong; Sol, Chang Hyo; Kim, Byung Soo

    1985-01-01

    The authors performed percutaneous antegrade pyelography guided by ultrasound on 33 patients, from June 1982 to October 1984, at the Department of Radiology, Busan National University Hospital. The results obtained were as follows: 1. Of the 31 cases, 17 cases (51.5%) were female and 16 cases (48.5%) were male, and age distribution was nearly even, but most prevalent age group was third decade. 2. Comparing intravenous pyelographic findings with ultrasonographic findings, pyelographically nonvisualized kidney 15 cases (45.5%) were hydronephrosis 12 cases, multiple cysts 2 cases, and intrarenal cystic mass 1 case, ultrasonographically. Pyelographically hydronephrosis 9 cases (27.3%) were all hydronephrosis, ultrasonographically. Intrarenal mass 5 cases (15.2%) were all intrarenal cystic mass, NVK with air kidney 1 case (3.0%) was air in perirenal space, partial NVK 1 case (3.0%) was perirenal fluid, suprarenal mass 1 case (3.0%) was suprarenal intrarenal and huge perirenal cystic masses, ultrasonographically. 3. On technical reliability of antegrade pyelography under ultrasound guide, 31 cases (93.9%) could be done fluid aspiration and visualization, and 2 cases (6.1%) could be only done fluid aspiration but failed visualization. 31 successful cases were visualization of collecting systems 23 cases, visualization of cyst 6 case, and visualization of perirenal space 2 cases. 2 partical successful cases were perirenal injection 1 case and parenchymal injection 1 case. 4. On fluid aspiration, 22 cases (66.7%) were clear, but 11 cases (33.3%) were not clear, which were pus 7 cases, turbid urine 2 cases, bloody urine 1 case, and bloody pus and air 1 case. 5. Comparing ultrasonographic findings with antegrade pyelographic findings, ultrasonographiclly hydronephrosis 21 cases revealed obstruction in 16 cases, antegrade pyelographicaaly, which were consisted of ureteral stricture 14 case, ureteral stone 1 case, and ureteral mass 1 case, non-obstruction in 4 cases, which

  16. Diagnostic accuracy of a noninvasive hepatic ultrasound score for non-alcoholic fatty liver disease (NAFLD in the Brazilian Longitudinal Study of Adult Health (ELSA-Brasil

    Directory of Open Access Journals (Sweden)

    Alessandra Carvalho Goulart

    Full Text Available CONTEXT AND OBJECTIVE: Noninvasive strategies for evaluating non-alcoholic fatty liver disease (NAFLD have been investigated over the last few decades. Our aim was to evaluate the diagnostic accuracy of a new hepatic ultrasound score for NAFLD in the ELSA-Brasil study. DESIGN AND SETTINGS: Diagnostic accuracy study conducted in the ELSA center, in the hospital of a public university. METHODS: Among the 15,105 participants of the ELSA study who were evaluated for NAFLD, 195 individuals were included in this sub-study. Hepatic ultrasound was performed (deep beam attenuation, hepatorenal index and anteroposterior diameter of the right hepatic lobe and compared with the hepatic steatosis findings from 64-channel high-resolution computed tomography (CT. We also evaluated two clinical indices relating to NAFLD: the fatty liver index (FLI and the hepatic steatosis index (HSI. RESULTS: Among the 195 participants, the NAFLD frequency was 34.4%. High body mass index, high waist circumference, diabetes and hypertriglyceridemia were associated with high hepatic attenuation and large anteroposterior diameter of the right hepatic lobe, but not with the hepatorenal index. The hepatic ultrasound score, based on hepatic attenuation and the anteroposterior diameter of the right hepatic lobe, presented the best performance for NAFLD screening at the cutoff point ≥ 1 point; sensitivity: 85.1%; specificity: 73.4%; accuracy: 79.3%; and area under the curve (AUC 0.85; 95% confidence interval, CI: 0.78-0.91]. FLI and HSI presented lower performance (AUC 0.76; 95% CI: 0.69-0.83 than CT. CONCLUSION: The hepatic ultrasound score based on hepatic attenuation and the anteroposterior diameter of the right hepatic lobe has good reproducibility and accuracy for NAFLD screening.

  17. Diagnostic accuracy of a noninvasive hepatic ultrasound score for non-alcoholic fatty liver disease (NAFLD) in the Brazilian Longitudinal Study of Adult Health (ELSA-Brasil).

    Science.gov (United States)

    Goulart, Alessandra Carvalho; Oliveira, Ilka Regina Souza de; Alencar, Airlane Pereira; Santos, Maira Solange Camara dos; Santos, Itamar Souza; Martines, Brenda Margatho Ramos; Meireles, Danilo Peron; Martines, João Augusto dos Santos; Misciagna, Giovanni; Benseñor, Isabela Martins; Lotufo, Paulo Andrade

    2015-01-01

    Noninvasive strategies for evaluating non-alcoholic fatty liver disease (NAFLD) have been investigated over the last few decades. Our aim was to evaluate the diagnostic accuracy of a new hepatic ultrasound score for NAFLD in the ELSA-Brasil study. Diagnostic accuracy study conducted in the ELSA center, in the hospital of a public university. Among the 15,105 participants of the ELSA study who were evaluated for NAFLD, 195 individuals were included in this sub-study. Hepatic ultrasound was performed (deep beam attenuation, hepatorenal index and anteroposterior diameter of the right hepatic lobe) and compared with the hepatic steatosis findings from 64-channel high-resolution computed tomography (CT). We also evaluated two clinical indices relating to NAFLD: the fatty liver index (FLI) and the hepatic steatosis index (HSI). Among the 195 participants, the NAFLD frequency was 34.4%. High body mass index, high waist circumference, diabetes and hypertriglyceridemia were associated with high hepatic attenuation and large anteroposterior diameter of the right hepatic lobe, but not with the hepatorenal index. The hepatic ultrasound score, based on hepatic attenuation and the anteroposterior diameter of the right hepatic lobe, presented the best performance for NAFLD screening at the cutoff point ≥ 1 point; sensitivity: 85.1%; specificity: 73.4%; accuracy: 79.3%; and area under the curve (AUC 0.85; 95% confidence interval, CI: 0.78-0.91)]. FLI and HSI presented lower performance (AUC 0.76; 95% CI: 0.69-0.83) than CT. The hepatic ultrasound score based on hepatic attenuation and the anteroposterior diameter of the right hepatic lobe has good reproducibility and accuracy for NAFLD screening.

  18. Preliminary Clinical Experience with a Combined Automated Breast Ultrasound and Digital Breast Tomosynthesis System.

    Science.gov (United States)

    Larson, Eric D; Lee, Won-Mean; Roubidoux, Marilyn A; Goodsitt, Mitchell M; Lashbrook, Chris; Davis, Cynthia E; Kripfgans, Oliver D; Carson, Paul L

    2018-03-01

    We analyzed the performance of a mammographically configured, automated breast ultrasound (McABUS) scanner combined with a digital breast tomosynthesis (DBT) system. The GE Invenia ultrasound system was modified for integration with GE DBT systems. Ultrasound and DBT imaging were performed in the same mammographic compression. Our small preliminary study included 13 cases, six of whom had contained invasive cancers. From analysis of these cases, current limitations and corresponding potential improvements of the system were determined. A registration analysis was performed to compare the ease of McABUS to DBT registration for this system with that of two systems designed previously. It was observed that in comparison to data from an earlier study, the McABUS-to-DBT registration alignment errors for both this system and a previously built combined system were smaller than those for a previously built standalone McABUS system. Copyright © 2018 World Federation for Ultrasound in Medicine and Biology. Published by Elsevier Inc. All rights reserved.

  19. Advances in point-of-care ultrasound in pediatric emergency medicine.

    Science.gov (United States)

    Gallagher, Rachel A; Levy, Jason A

    2014-06-01

    Point-of-care ultrasound (POCUS) has become an integral part of emergency medicine practice. Research evaluating POCUS in the care of pediatric patients has improved the understanding of its potential role in clinical care. Recent work has investigated the ability of pediatric emergency medicine (PEM) physicians to perform a wide array of diagnostic and procedural applications in POCUS ultrasound. Studies have demonstrated that PEM providers are able to identify an array of diseases, including intussusception, pyloric stenosis and appendicitis. Novel applications of ultrasound, such as a cardiac evaluation in the acutely ill patient or identification of skull fractures in the assessment of a patient with head injury, have shown excellent promise in recent studies. These novel applications have the potential to reshape pediatric diagnostic algorithms. Key applications in PEM have been investigated in the recent publications. Further exploration of the ability to integrate ultrasound into routine practice will require larger-scale studies and continued growth of education in the field. The use of ultrasound in clinical practice has the potential to improve safety and efficiency of care in the pediatric emergency department.

  20. The utility of ultrasound superb microvascular imaging for evaluation of breast tumour vascularity: comparison with colour and power Doppler imaging regarding diagnostic performance.

    Science.gov (United States)

    Park, A Y; Seo, B K; Woo, O H; Jung, K S; Cho, K R; Park, E K; Cha, S H; Cha, J

    2018-03-01

    To investigate the utility of superb microvascular imaging (SMI) for evaluating the vascularity of breast masses in comparison with colour or power Doppler ultrasound (US) and the effect on diagnostic performance. A total of 191 biopsy-proven masses (99 benign and 92 malignant) in 166 women with greyscale, colour Doppler, power Doppler, and SMI images were enrolled in this retrospective study. Three radiologists analysed the vascular images using a three-factor scoring system to evaluate the number, morphology, and distribution of tumour vessels. They assessed the Breast Imaging-Reporting and Data System categories for greyscale US alone and combinations of greyscale US and each type of vascular US. The Kruskal-Wallis test was performed and the area under the receiver-operating characteristic curve (AUC) measured. On SMI, vascular scores were compared between benign and malignant masses and the optimal cut-off value for the overall score was determined. SMI showed higher vascular scores than colour or power Doppler US and malignant masses had higher scores than benign masses (ppower Doppler US (AUC, 0.815 versus 0.774, 0.789, 0.791; ppower Doppler US for characterising the vascularity in breast masses and improving diagnostic performance. Copyright © 2017 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  1. Mobile point-of-care monitors and diagnostic device design

    CERN Document Server

    Karlen, Walter

    2014-01-01

    PrefaceEditorsContributorsSensors and SystemsInterfacing Diagnostics with Consumer ElectronicsPakorn Preechaburana, Anke Suska, and Daniel FilippiniLab on a CellphoneAhmet F. Coskun, Hongying Zhu, Onur Mudanyali, and Aydogan OzcanThe Phone OximeterChristian Leth PetersenCurrent Technology and Advances in Transepidermal Water Loss SensorsPietro Salvo, Bernardo Melai, Nicola Calisi, and Fabio Di FrancescoPortable High-Frequency Ultrasound Imaging System Design and Hardware Considerations

  2. Lumbar ultrasound: useful gadget or time-consuming gimmick?

    Science.gov (United States)

    Gambling, D R

    2011-10-01

    Despite widespread enthusiasm for using lumbar ultrasound in obstetrics, there are some who believe it is expensive and time-consuming, with undetermined risks and uncertain benefits. For decades, anesthesiologists have striven to perfect the identification and cannulation of the epidural space using skills learned during training and early clinical practice. These skills include knowledge of the relevant anatomy and detection of subtle tactile clues that aid successful placement of an epidural catheter. Indeed, obstetric anesthesiologists have managed to do this with great success without using imaging techniques. There is a long learning curve associated with lumbar ultrasound and it is unclear from the literature if the success rates associated with its use are superior to clinical skill alone. Is it only a matter of time before regulators insist that lumbar ultrasound is used before inserting an epidural? Indeed, this has already happened for central vein catheters. The United States spent $2.2 trillion on health care in 2007, nearly twice the average of other developed nations. If rapid health cost growth persists, one out of every four dollars in the US national economy will be tied up in the health system by 2025. Do obstetric anesthesiologists want to add to these costs by using unnecessary and expensive equipment? Although many feel that diagnostic ultrasound in obstetrics is safe, some argue that we have yet to perform an appropriate risk analysis for lumbar ultrasound during pregnancy. The issue of ultrasound bio-safety needs to be considered before we all jump on the ultrasound bandwagon. Copyright © 2010 Elsevier Ltd. All rights reserved.

  3. Reliability of diagnostic imaging techniques in suspected acute appendicitis: proposed diagnostic protocol

    International Nuclear Information System (INIS)

    Cura del, J. L.; Oleaga, L.; Grande, D.; Vela, A. C.; Ibanez, A. M.

    2001-01-01

    To study the utility of ultrasound and computed tomography (CT) in case of suspected appendicitis. To determine the diagnostic yield in terms of different clinical contexts and patient characteristics. to assess the costs and benefits of introducing these techniques and propose a protocol for their use. Negative appendectomies, complications and length of hospital stay in a group of 152 patients with suspected appendicitis who underwent ultrasound and CT were compared with those of 180 patients who underwent appendectomy during the same time period, but had not been selected for the first group: these patients costs for each group were calculated. In the first group, the diagnostic value of the clinical signs was also evaluated. The reliability of the clinical signs was limited, while the results with ultrasound and CT were excellent. The incidence of negative appendectomy was 9.6% in the study group and 12.2% in the control group. Moreover, there were fewer complications and a shorter hospital stay in the first group. Among men, however, the rate of negative appendectomy was lower in the control group. The cost of using ultrasound and CT in the management of appendicitis was only slightly higher than that of the control group. Although ultrasound and CT are not necessary in cases in which the probability of appendicitis is low or in men presenting clear clinical evidence, the use of these techniques is indicated in the remaining cases in which appendicitis is suspected. In children, ultrasound is the technique of choice. In all other patients, if negative results are obtained with one of the two techniques, the other should be performed. (Author) 49 refs

  4. Scaling-Up the Functional Diagnostic Systems

    International Nuclear Information System (INIS)

    Mohamed, A.H.

    2008-01-01

    Functional diagnostic systems received a lot of attention in the last decade. They have proven their powerful for diagnosis the new faults of some complex systems. But, they still have some complexity in both the representation and reasoning about the large-scale systems. This paper introduces a new functional diagnostic system that can divide its small functions into main and auxiliary ones. This process enables the diagnostic system to scale -up the representation of the tested system and simplify the diagnostic mechanism tasks. Thus, it can improve both the representation and reasoning complexity. Also,it can decrease the required analysis, cost, and time. Proposed system can be applied for a wide area of the large-scale systems. It has been proven its acceptance to be applied practically for the Complex real-time systems

  5. A Standard Mammography Unit - Standard 3D Ultrasound Probe Fusion Prototype: First Results.

    Science.gov (United States)

    Schulz-Wendtland, Rüdiger; Jud, Sebastian M; Fasching, Peter A; Hartmann, Arndt; Radicke, Marcus; Rauh, Claudia; Uder, Michael; Wunderle, Marius; Gass, Paul; Langemann, Hanna; Beckmann, Matthias W; Emons, Julius

    2017-06-01

    The combination of different imaging modalities through the use of fusion devices promises significant diagnostic improvement for breast pathology. The aim of this study was to evaluate image quality and clinical feasibility of a prototype fusion device (fusion prototype) constructed from a standard tomosynthesis mammography unit and a standard 3D ultrasound probe using a new method of breast compression. Imaging was performed on 5 mastectomy specimens from patients with confirmed DCIS or invasive carcinoma (BI-RADS ™ 6). For the preclinical fusion prototype an ABVS system ultrasound probe from an Acuson S2000 was integrated into a MAMMOMAT Inspiration (both Siemens Healthcare Ltd) and, with the aid of a newly developed compression plate, digital mammogram and automated 3D ultrasound images were obtained. The quality of digital mammogram images produced by the fusion prototype was comparable to those produced using conventional compression. The newly developed compression plate did not influence the applied x-ray dose. The method was not more labour intensive or time-consuming than conventional mammography. From the technical perspective, fusion of the two modalities was achievable. In this study, using only a few mastectomy specimens, the fusion of an automated 3D ultrasound machine with a standard mammography unit delivered images of comparable quality to conventional mammography. The device allows simultaneous ultrasound - the second important imaging modality in complementary breast diagnostics - without increasing examination time or requiring additional staff.

  6. Recent advances of ultrasound imaging in dentistry--a review of the literature.

    Science.gov (United States)

    Marotti, Juliana; Heger, Stefan; Tinschert, Joachim; Tortamano, Pedro; Chuembou, Fabrice; Radermacher, Klaus; Wolfart, Stefan

    2013-06-01

    Ultrasonography as an imaging modality in dentistry has been extensively explored in recent years due to several advantages that diagnostic ultrasound provides. It is a non-invasive, inexpensive, painless method and unlike X-ray, it does not cause harmful ionizing radiation. Ultrasound has a promising future as a diagnostic imaging tool in all specialties in dentistry, for both hard and soft tissue detection. The aim of this review is to provide the scientific community and clinicians with an overview of the most recent advances of ultrasound imaging in dentistry. The use of ultrasound is described and discussed in the fields of dental scanning, caries detection, dental fractures, soft tissue and periapical lesions, maxillofacial fractures, periodontal bony defects, gingival and muscle thickness, temporomandibular disorders, and implant dentistry. Copyright © 2013 Elsevier Inc. All rights reserved.

  7. Nova target diagnostics control system

    International Nuclear Information System (INIS)

    Severyn, J.R.

    1985-01-01

    During the past year the Nova target diagnostics control system was finished and put in service. The diagnostics loft constructed to the north of the target room provides the environmental conditions required to collect reliable target diagnostic data. These improvements include equipment cooling and isolation of the power source with strict control of instrumentation grounds to eliminate data corruption due to electromagnetic pulses from the laser power-conditioning system or from target implosion effects

  8. Computerized Diagnostic Assistant for the Automatic Detection of Pneumothorax on Ultrasound: A Pilot Study

    Directory of Open Access Journals (Sweden)

    Shane M. Summers, MD, RDMS

    2016-03-01

    Full Text Available Introduction: Bedside thoracic ultrasound (US can rapidly diagnose pneumothorax (PTX with improved accuracy over the physical examination and without the need for chest radiography (CXR; however, US is highly operator dependent. A computerized diagnostic assistant was developed by the United States Army Institute of Surgical Research to detect PTX on standard thoracic US images. This computer algorithm is designed to automatically detect sonographic signs of PTX by systematically analyzing B-mode US video clips for pleural sliding and M-mode still images for the seashore sign. This was a pilot study to estimate the diagnostic accuracy of the PTX detection computer algorithm when compared to an expert panel of US trained physicians. Methods: This was a retrospective study using archived thoracic US obtained on adult patients presenting to the emergency department (ED between 5/23/2011 and 8/6/2014. Emergency medicine residents, fellows, attending physicians, physician assistants, and medical students performed the US examinations and stored the images in the picture archive and communications system (PACS. The PACS was queried for all ED bedside US examinations with reported positive PTX during the study period along with a random sample of negatives. The computer algorithm then interpreted the images, and we compared the results to an independent, blinded expert panel of three physicians, each with experience reviewing over 10,000 US examinations. Results: Query of the PACS system revealed 146 bedside thoracic US examinations for analysis. Thirteen examinations were indeterminate and were excluded. There were 79 true negatives, 33 true positives, 9 false negatives, and 12 false positives. The test characteristics of the algorithm when compared to the expert panel were sensitivity 79% (95 % CI [63-89] and specificity 87% (95% CI [77-93]. For the 20 images scored as highest quality by the expert panel, the algorithm demonstrated 100% sensitivity

  9. Usefulness of emergency ultrasound in nontraumatic cardiac arrest.

    Science.gov (United States)

    Volpicelli, Giovanni

    2011-02-01

    Treatment of nontraumatic cardiac arrest in the hospital setting depends on the recognition of heart rhythm and differential diagnosis of the underlying condition while maintaining a constant oxygenated blood flow by ventilation and chest compression. Diagnostic process relies only on patient's history, physical findings, and active electrocardiography. Ultrasound is not currently scheduled in the resuscitation guidelines. Nevertheless, the use of real-time ultrasonography during resuscitation has the potential to improve diagnostic accuracy and allows the physician a greater confidence in deciding aggressive life-saving therapeutic procedures. This article reviews the current opinions and literature about the use of emergency ultrasound during resuscitation of nontraumatic cardiac arrest. Cardiac and lung ultrasound have a great potential in identifying the reversible mechanical causes of pulseless electrical activity or asystole. Brief examination of the heart can even detect a real cardiac standstill regardless of electrical activity displayed on the monitor, which is a crucial prognostic indicator. Moreover, ultrasound can be useful to verify and monitor the tracheal tube placement. Limitation to the use of ultrasound is the need to minimize the no-flow intervals during mechanical cardiopulmonary resuscitation. However, real-time ultrasound can be successfully applied during brief pausing of chest compression and first pulse-check. Finally, lung sonographic examination targeted to the detection of signs of pulmonary congestion has the potential to allow hemodynamic noninvasive monitoring before and after mechanical cardiopulmonary maneuvers. Copyright © 2011 Elsevier Inc. All rights reserved.

  10. Bedside ultrasound reliability in locating catheter and detecting complications

    Directory of Open Access Journals (Sweden)

    Payman Moharamzadeh

    2016-10-01

    Full Text Available Introduction: Central venous catheterization is one of the most common medical procedures and is associated with such complications as misplacement and pneumothorax. Chest X-ray is among good ways for evaluation of these complications. However, due to patient’s excessive exposure to radiation, time consumption and low diagnostic value in detecting pneumothorax in the supine patient, the present study intends to examine bedside ultrasound diagnostic value in locating tip of the catheter and pneumothorax. Materials and methods: In the present cross-sectional study, all referred patients requiring central venous catheterization were examined. Central venous catheterization was performed by a trained emergency medicine specialist, and the location of catheter and the presence of pneumothorax were examined and compared using two modalities of ultrasound and x-ray (as the reference standard. Sensitivity, specificity, and positive and negative predicting values were reported. Results: A total of 200 non-trauma patients were included in the study (58% men. Cohen’s Kappa consistency coefficients for catheterization and diagnosis of pneumothorax were found as 0.49 (95% CI: 0.43-0.55, 0.89 (P<0.001, (95% CI: 97.8-100, respectively. Also, ultrasound sensitivity and specificity in diagnosing pneumothorax were 75% (95% CI: 35.6-95.5, and 100% (95% CI: 97.6-100, respectively. Conclusion: The present study results showed low diagnostic value of ultrasound in determining catheter location and in detecting pneumothorax. With knowledge of previous studies, the search still on this field.   Keywords: Central venous catheterization; complications; bedside ultrasound; radiography;

  11. Ultrasound in obstetric anaesthesia: a review of current applications.

    LENUS (Irish Health Repository)

    Ecimovic, P

    2010-07-01

    Ultrasound equipment is increasingly used by non-radiologists to perform interventional techniques and for diagnostic evaluation. Equipment is becoming more portable and durable, with easier user-interface and software enhancement to improve image quality. While obstetric utilisation of ultrasound for fetal assessment has developed over more than 40years, the same technology has not found a widespread role in obstetric anaesthesia. Within the broader specialty of anaesthesia; vascular access, cardiac imaging and regional anaesthesia are the areas in which ultrasound is becoming increasingly established. In addition to ultrasound for neuraxial blocks, these other clinical applications may be of value in obstetric anaesthesia practice.

  12. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... young children. It is also valuable for evaluating the brain, spinal cord and hip joints in newborns and infants. Risks For standard diagnostic ultrasound , there are no known harmful effects on humans. top of page What are the limitations of ...

  13. Applying Diagnostics to Enhance Cable System Reliability (Cable Diagnostic Focused Initiative, Phase II)

    Energy Technology Data Exchange (ETDEWEB)

    Hartlein, Rick [Georgia Tech Research Corporation (GTRC), Atlanta, GA (United States). National Electric Energy Testing, Research and Applications Center (NEETRAC); Hampton, Nigel [Georgia Tech Research Corporation (GTRC), Atlanta, GA (United States). National Electric Energy Testing, Research and Applications Center (NEETRAC); Perkel, Josh [Georgia Tech Research Corporation (GTRC), Atlanta, GA (United States). National Electric Energy Testing, Research and Applications Center (NEETRAC); Hernandez, JC [Univ. de Los Andes, Merida (Venezuela); Elledge, Stacy [Georgia Tech Research Corporation (GTRC), Atlanta, GA (United States). National Electric Energy Testing, Research and Applications Center (NEETRAC); del Valle, Yamille [Georgia Tech Research Corporation (GTRC), Atlanta, GA (United States). National Electric Energy Testing, Research and Applications Center (NEETRAC); Grimaldo, Jose [Georgia Inst. of Technology, Atlanta, GA (United States). School of Electrical and Computer Engineering; Deku, Kodzo [Georgia Inst. of Technology, Atlanta, GA (United States). George W. Woodruff School of Mechanical Engineering

    2016-02-01

    The Cable Diagnostic Focused Initiative (CDFI) played a significant and powerful role in clarifying the concerns and understanding the benefits of performing diagnostic tests on underground power cable systems. This project focused on the medium and high voltage cable systems used in utility transmission and distribution (T&D) systems. While many of the analysis techniques and interpretations are applicable to diagnostics and cable systems outside of T&D, areas such as generating stations (nuclear, coal, wind, etc.) and other industrial environments were not the focus. Many large utilities in North America now deploy diagnostics or have changed their diagnostic testing approach as a result of this project. Previous to the CDFI, different diagnostic technology providers individually promoted their approach as the “the best” or “the only” means of detecting cable system defects.

  14. A procedure to detect flaws inside large size marble blocks by ultrasound

    OpenAIRE

    Bramanti, Mauro; Bozzi, Edoardo

    1999-01-01

    In stone and marble industry there is considerable interest in the possibility of using ultrasound diagnostic techniques for non-destructive testing of large size blocks in order to detect internal flaws such as faults, cracks and fissures. In this paper some preliminary measurements are reported in order to acquire basic knowledge of the fundamental properties of ultrasound, such as propagation velocity and attenuation, in the media here considered. We then outline a particular diagnostic pr...

  15. Ultrasound of the coracoclavicular ligaments in the acute phase of an acromioclavicular disjonction: Comparison of radiographic, ultrasound and MRI findings.

    Science.gov (United States)

    Faruch Bilfeld, Marie; Lapègue, Franck; Chiavassa Gandois, Hélène; Bayol, Marie Aurélie; Bonnevialle, Nicolas; Sans, Nicolas

    2017-02-01

    Acromioclavicular joint injuries are typically diagnosed by clinical and radiographic assessment with the Rockwood classification, which is crucial for treatment planning. The purpose of this study was to describe how the ultrasound findings of acromioclavicular joint injury compare with radiography and MRI findings. Forty-seven patients with suspected unilateral acromioclavicular joint injury after acute trauma were enrolled in this prospective study. All patients underwent digital radiography, ultrasound and 3T MRI. A modified Rockwood classification was used to evaluate the coracoclavicular ligaments. The classifications of acromioclavicular joint injuries diagnosed with radiography, ultrasound and MRI were compared. MRI was used as the gold standard. The agreement between the ultrasound and MRI findings was very good, with a correlation coefficient of 0.83 (95 % CI: 0.72-0.90; p acromioclavicular injury. • Ultrasound is appropriate for acute acromioclavicular trauma due to its accessibility. • Ultrasound contributes to the diagnostic work-up of acute lesions of the coracoclavicular ligaments. • Ultrasound is appropriate in patients likely to benefit from surgical treatment. • Ultrasound could be a supplement to standard radiography in acute acromioclavicular trauma.

  16. Antenatal diagnosis of anophthalmia by three-dimensional ultrasound: a novel application of the reverse face view.

    Science.gov (United States)

    Wong, H S; Parker, S; Tait, J; Pringle, K C

    2008-07-01

    The prenatal diagnosis of anophthalmia can be made on the demonstration of absent eye globe and lens on the affected side(s) on two-dimensional ultrasound examination, but when the fetal head position is unfavorable three-dimensional (3D) ultrasound may reveal additional diagnostic sonographic features, including sunken eyelids and small or hypoplastic orbit on the affected side(s). We present two cases of isolated anophthalmia diagnosed on prenatal ultrasound examination in which 3D ultrasound provided additional diagnostic information. The reverse face view provides valuable information about the orbits and the eyeballs for prenatal diagnosis and assessment of anophthalmia.

  17. A review of suspension-Scattered particles used in blood-mimicking fluid for doppler ultrasound imaging

    Directory of Open Access Journals (Sweden)

    Ammar A Oglat

    2018-01-01

    Full Text Available Doppler ultrasound imaging system description and calibration need blood-mimicking fluids (BMFs for the test target of medical ultrasound diagnostic tools, with known interior features and acoustic and physical properties of this fluid (BMF. Physical and acoustical properties determined in the International Electrotechnical Commission (IEC standard are specified as constant values, the materials used in the BMF preparation should have values similar to the IEC standard values. However, BMF is ready-made commercially from a field of medical usage, which may not be appropriate in the layout of ultrasound system or for an estimate of novel imaging mechanism. It is often eligible to have the capability to make sound properties and mimic blood arrangement for specific applications. In this review, sufficient BMF materials, liquids, and measures are described which have been generated by utilizing diverse operation mechanism and materials that have sculptured a range of biological systems.

  18. Secondary Signs May Improve the Diagnostic Accuracy of Equivocal Ultrasounds for Suspected Appendicitis in Children

    Science.gov (United States)

    Partain, Kristin N.; Patel, Adarsh; Travers, Curtis; McCracken, Courtney; Loewen, Jonathan; Braithwaite, Kiery; Heiss, Kurt F.; Raval, Mehul V.

    2016-01-01

    Introduction Ultrasound (US) is the preferred imaging modality for evaluating appendicitis. Our purpose was to determine if including secondary signs (SS) improves diagnostic accuracy in equivocal US studies. Methods Retrospective review identified 825 children presenting with concern for appendicitis and with a right lower quadrant (RLQ) US. Regression models identified which SS were associated with appendicitis. Test characteristics were demonstrated. Results 530 patients (64%) had equivocal US reports. Of 114 (22%) patients with equivocal US undergoing CT, those with SS were more likely to have appendicitis (48.6% vs 14.6%, pappendicitis (61.0% vs 33.6%, pappendicitis included fluid collection (adjusted odds ratio (OR) 13.3, 95% Confidence Interval (CI) 2.1–82.8), hyperemia (OR=2.0, 95%CI 1.5–95.5), free fluid (OR=9.8, 95%CI 3.8–25.4), and appendicolith (OR=7.9, 95%CI 1.7–37.2). Wall thickness, bowel peristalsis, and echogenic fat were not associated with appendicitis. Equivocal US that included hyperemia, a fluid collection, or an appendicolith had 96% specificity and 88% accuracy. Conclusion Use of SS in RLQ US assists in the diagnostic accuracy of appendicitis. SS may guide clinicians and reduce unnecessary CT and admissions. PMID:27039121

  19. Ultrasound-Mediated Local Drug and Gene Delivery Using Nanocarriers

    Science.gov (United States)

    Zhou, Qiu-Lan; Chen, Zhi-Yi; Yang, Feng

    2014-01-01

    With the development of nanotechnology, nanocarriers have been increasingly used for curative drug/gene delivery. Various nanocarriers are being introduced and assessed, such as polymer nanoparticles, liposomes, and micelles. As a novel theranostic system, nanocarriers hold great promise for ultrasound molecular imaging, targeted drug/gene delivery, and therapy. Nanocarriers, with the properties of smaller particle size, and long circulation time, would be advantageous in diagnostic and therapeutic applications. Nanocarriers can pass through blood capillary walls and cell membrane walls to deliver drugs. The mechanisms of interaction between ultrasound and nanocarriers are not clearly understood, which may be related to cavitation, mechanical effects, thermal effects, and so forth. These effects may induce transient membrane permeabilization (sonoporation) on a single cell level, cell death, and disruption of tissue structure, ensuring noninvasive, targeted, and efficient drug/gene delivery and therapy. The system has been used in various tissues and organs (in vitro or in vivo), including tumor tissues, kidney, cardiac, skeletal muscle, and vascular smooth muscle. In this review, we explore the research progress and application of ultrasound-mediated local drug/gene delivery with nanocarriers. PMID:25202710

  20. Ultrasound-Mediated Local Drug and Gene Delivery Using Nanocarriers

    Directory of Open Access Journals (Sweden)

    Qiu-Lan Zhou

    2014-01-01

    Full Text Available With the development of nanotechnology, nanocarriers have been increasingly used for curative drug/gene delivery. Various nanocarriers are being introduced and assessed, such as polymer nanoparticles, liposomes, and micelles. As a novel theranostic system, nanocarriers hold great promise for ultrasound molecular imaging, targeted drug/gene delivery, and therapy. Nanocarriers, with the properties of smaller particle size, and long circulation time, would be advantageous in diagnostic and therapeutic applications. Nanocarriers can pass through blood capillary walls and cell membrane walls to deliver drugs. The mechanisms of interaction between ultrasound and nanocarriers are not clearly understood, which may be related to cavitation, mechanical effects, thermal effects, and so forth. These effects may induce transient membrane permeabilization (sonoporation on a single cell level, cell death, and disruption of tissue structure, ensuring noninvasive, targeted, and efficient drug/gene delivery and therapy. The system has been used in various tissues and organs (in vitro or in vivo, including tumor tissues, kidney, cardiac, skeletal muscle, and vascular smooth muscle. In this review, we explore the research progress and application of ultrasound-mediated local drug/gene delivery with nanocarriers.

  1. Endoscopic Ultrasound Elastography: Current Clinical Use in Pancreas.

    Science.gov (United States)

    Mondal, Utpal; Henkes, Nichole; Patel, Sandeep; Rosenkranz, Laura

    2016-08-01

    Elastography is a newer technique for the assessment of tissue elasticity using ultrasound. Cancerous tissue is known to be stiffer (hence, less elastic) than corresponding healthy tissue, and as a result, could be identified in an elasticity-based imaging. Ultrasound elastography has been used in the breast, thyroid, and cervix to differentiate malignant from benign neoplasms and to guide or avoid unnecessary biopsies. In the liver, elastography has enabled a noninvasive and reliable estimate of fibrosis. Endoscopic ultrasound has become a robust diagnostic and therapeutic tool for the management of pancreatic diseases. The addition of elastography to endoscopic ultrasound enabled further characterization of pancreas lesions, and several European and Asian studies have reported encouraging results. The current clinical role of endoscopic ultrasound elastography in the management of pancreas disorders and related literature are reviewed.

  2. Children's (Pediatric) Abdominal Ultrasound Imaging

    Medline Plus

    Full Text Available ... particularly valuable for evaluating abdominal, pelvic or scrotal pain in young children. It is also valuable for evaluating the brain, spinal cord and hip joints in newborns and infants. Risks For standard diagnostic ultrasound , there are no known harmful effects on ...

  3. Visualization of the diaphragm muscle with ultrasound improves diagnostic accuracy of phrenic nerve conduction studies.

    Science.gov (United States)

    Johnson, Nicholas E; Utz, Michael; Patrick, Erica; Rheinwald, Nicole; Downs, Marlene; Dilek, Nuran; Dogra, Vikram; Logigian, Eric L

    2014-05-01

    Evaluation of phrenic neuropathy (PN) with phrenic nerve conduction studies (PNCS) is associated with false negatives. Visualization of diaphragmatic muscle twitch with diaphragm ultrasound (DUS) when performing PNCS may help to solve this problem. We performed bilateral, simultaneous DUS-PNCS in 10 healthy adults and 12 patients with PN. The amplitude of the diaphragm compound muscle action potential (CMAP) (on PNCS) and twitch (on DUS) was calculated. Control subjects had phrenic CMAP (on PCNS). In the 12 patients with PN, 12 phrenic neuropathies were detected. Three of these patients had either significant side-to-side asymmetry or absolute reduction in diaphragm movement that was not detected with PNCS. There were no cases in which the PNCS showed an abnormality but the DUS did not. The addition of DUS to PNCS enhances diagnostic accuracy in PN. Copyright © 2013 Wiley Periodicals, Inc.

  4. A multicenter hospital-based diagnosis study of automated breast ultrasound system in detecting breast cancer among Chinese women.

    Science.gov (United States)

    Zhang, Xi; Lin, Xi; Tan, Yanjuan; Zhu, Ying; Wang, Hui; Feng, Ruimei; Tang, Guoxue; Zhou, Xiang; Li, Anhua; Qiao, Youlin

    2018-04-01

    The automated breast ultrasound system (ABUS) is a potential method for breast cancer detection; however, its diagnostic performance remains unclear. We conducted a hospital-based multicenter diagnostic study to evaluate the clinical performance of the ABUS for breast cancer detection by comparing it to handheld ultrasound (HHUS) and mammography (MG). Eligible participants underwent HHUS and ABUS testing; women aged 40-69 years additionally underwent MG. Images were interpreted using the Breast Imaging Reporting and Data System (BI-RADS). Women in the BI-RADS categories 1-2 were considered negative. Women classified as BI-RADS 3 underwent magnetic resonance imaging to distinguish true- and false-negative results. Core aspiration or surgical biopsy was performed in women classified as BI-RADS 4-5, followed by a pathological diagnosis. Kappa values and agreement rates were calculated between ABUS, HHUS and MG. A total of 1,973 women were included in the final analysis. Of these, 1,353 (68.6%) and 620 (31.4%) were classified as BI-RADS categories 1-3 and 4-5, respectively. In the older age group, the agreement rate and Kappa value between the ABUS and HHUS were 94.0% and 0.860 (P<0.001), respectively; they were 89.2% and 0.735 (P<0.001) between the ABUS and MG, respectively. Regarding consistency between imaging and pathology results, 78.6% of women classified as BI-RADS 4-5 based on the ABUS were diagnosed with precancerous lesions or cancer; which was 7.2% higher than that of women based on HHUS. For BI-RADS 1-2, the false-negative rates of the ABUS and HHUS were almost identical and were much lower than those of MG. We observed a good diagnostic reliability for the ABUS. Considering its performance for breast cancer detection in women with high-density breasts and its lower operator dependence, the ABUS is a promising option for breast cancer detection in China.

  5. Some aspects of diagnostic systems perspective

    International Nuclear Information System (INIS)

    Korosec, D.

    1998-01-01

    The integrity and safety of all nuclear power plant systems and components is guaranteed by the high requirements to quality assurance during all phases of design, fabrication, construction and operation. Many of the countries operating nuclear facilities, introduced advanced, sophisticated diagnostic systems for continuous monitoring safety important process parameters. The licensee should perform an assessment of the existing diagnostic systems, often supplied by the original design, their reliability and the need for the introduction of the additional monitoring/diagnostic systems. The operating experience should be taken into account and the assessment of the further needs. On this field has to be made on the results of PSA studies. In addition to the cost benefit analysis the evaluation of the new diagnostic systems in the light of nuclear safety should be also made. Experience, gained from the utilities, which have already installed this kind of the equipment should be very useful. Introducing new diagnostic systems will require often a safety assessment of the necessary modifications. Licensing process should be based on the existing nuclear legislation with certain additional requirements. (author)

  6. Musculoskeletal ultrasound: how to treat calcific tendinitis of the rotator cuff by ultrasound-guided single-needle lavage technique.

    Science.gov (United States)

    Lee, Kenneth S; Rosas, Humberto G

    2010-09-01

    The purpose of this video article is to illustrate the ultrasound appearance of calcium deposition in the rotator cuff and provide a detailed step-by-step protocol for performing the ultrasound-guided single-needle lavage technique for the treatment of calcific tendinitis with emphasis on patient positioning, necessary supplies, real-time lavage technique, and steroid injection into the subacromial subdeltoid bursa. Musculoskeletal ultrasound is well established as a safe, cost-effective imaging tool in diagnosing and treating common musculoskeletal disorders. Calcific tendinitis of the rotator cuff is a common disabling cause of shoulder pain. Although most cases are self-limiting, a subset of patients is refractory to conservative therapy and requires treatment intervention. Ultrasound-guided lavage is an effective and safe minimally-invasive treatment not readily offered in the United States as an alternative to surgery, perhaps because of the limited prevalence of musculoskeletal ultrasound programs and limited training. On completion of this video article, the participant should be able to develop an appropriate diagnostic and therapeutic algorithm for the treatment of calcific tendinitis of the rotator cuff using ultrasound.

  7. Challenges and regulatory considerations in the acoustic measurement of high-frequency (>20 MHz) ultrasound.

    Science.gov (United States)

    Nagle, Samuel M; Sundar, Guru; Schafer, Mark E; Harris, Gerald R; Vaezy, Shahram; Gessert, James M; Howard, Samuel M; Moore, Mary K; Eaton, Richard M

    2013-11-01

    This article examines the challenges associated with making acoustic output measurements at high ultrasound frequencies (>20 MHz) in the context of regulatory considerations contained in the US Food and Drug Administration industry guidance document for diagnostic ultrasound devices. Error sources in the acoustic measurement, including hydrophone calibration and spatial averaging, nonlinear distortion, and mechanical alignment, are evaluated, and the limitations of currently available acoustic measurement instruments are discussed. An uncertainty analysis of acoustic intensity and power measurements is presented, and an example uncertainty calculation is done on a hypothetical 30-MHz high-frequency ultrasound system. This analysis concludes that the estimated measurement uncertainty of the acoustic intensity is +73%/-86%, and the uncertainty in the mechanical index is +37%/-43%. These values exceed the respective levels in the Food and Drug Administration guidance document of 30% and 15%, respectively, which are more representative of the measurement uncertainty associated with characterizing lower-frequency ultrasound systems. Recommendations made for minimizing the measurement uncertainty include implementing a mechanical positioning system that has sufficient repeatability and precision, reconstructing the time-pressure waveform via deconvolution using the hydrophone frequency response, and correcting for hydrophone spatial averaging.

  8. [Monitoring radiofrequency ablation by ultrasound temperature imaging and elastography under different power intensities].

    Science.gov (United States)

    Geng, Xiaonan; Li, Qiang; Tsui, Pohsiang; Wang, Chiaoyin; Liu, Haoli

    2013-09-01

    To evaluate the reliability of diagnostic ultrasound-based temperature and elasticity imaging during radiofrequency ablation (RFA) through ex vivo experiments. Procine liver samples (n=7) were employed for RFA experiments with exposures of different power intensities (10 and 50w). The RFA process was monitored by a diagnostic ultrasound imager and the information were postoperatively captured for further temperature and elasticity image analysis. Infrared thermometry was concurrently applied to provide temperature change calibration during the RFA process. Results from this study demonstrated that temperature imaging was valid under 10 W RF exposure (r=0.95), but the ablation zone was no longer consistent with the reference infrared temperature distribution under high RF exposures. The elasticity change could well reflect the ablation zone under a 50 W exposure, whereas under low exposures, the thermal lesion could not be well detected due to the limited range of temperature elevation and incomplete tissue necrosis. Diagnostic ultrasound-based temperature and elastography is valid for monitoring thr RFA process. Temperature estimation can well reflect mild-power RF ablation dynamics, whereas the elastic-change estimation can can well predict the tissue necrosis. This study provide advances toward using diagnostic ultrasound to monitor RFA or other thermal-based interventions.

  9. Impact of new society of radiologists in ultrasound early first-trimester diagnostic criteria for nonviable pregnancy.

    Science.gov (United States)

    Hu, Maowen; Poder, Liina; Filly, Roy A

    2014-09-01

    New early first-trimester diagnostic criteria for nonviable pregnancy recommended by the Society of Radiologists in Ultrasound via a multispecialty consensus panel extended the diagnostic size criteria of crown-rump length from 5 to 7 mm for embryos without a heartbeat and mean sac diameter from 16 to 25 mm for "empty" sacs. Our study assessed the potential impact of the new criteria on the number of additional follow-up sonograms these changes would engender. A retrospective study of all first-trimester sonograms in women with first trimester bleeding from 1999 to 2008 was conducted. Everyone included in the study had a visible gestational sac in the uterus. There were no pregnancies of unknown location or ectopic pregnancies included in this study cohort. Pregnancy of unknown location was used to describe cases in which there were no signs of pregnancy inside or outside the uterus on transvaginal sonography despite a positive pregnancy test result. A total of 1013 patients met the inclusion criteria. Seven hundred fifty-two patients (74%) had identifiable embryos, and 261 (26%) did not. Of those with an identifiable embryo, 286 (38%) had no detectable embryonic cardiac activity. The breakdown of crown-rump lengths in this group was as follows: 100 measuring less than 5 mm, 36 measuring 5 to 7 mm, and 150 measuring 7 mm or greater. The breakdown of mean sac diameters in those without a visible embryo was as follows: 120 measuring less than 16 mm, 90 measuring 16 to 25 mm, and 51 measuring 25 mm or greater. When diagnosing a failed pregnancy, there can be no room for error. Only 126 of 1013 early pregnancies threatening to abort (12%) fell into the more conservative zones defined by the new compared to the former size criteria (crown-rump length, 5-7 mm; mean sac diameter, 16-25 mm). Therefore, the potential impact of the new guidelines on follow-up sonograms does not appear inordinate. © 2014 by the American Institute of Ultrasound in Medicine.

  10. Diagnostic imaging of the kidney and the urinary tract in infancy

    International Nuclear Information System (INIS)

    Troeger, J.; Darge, K.; Rohrschneider, W.

    1999-01-01

    Imaging flow charts differ in pediatric and general radiology. The reasons are: Different illnesses, different consequences arising out of imaging results and different sequence of imaging methods. Ultrasound is always the first imaging method of the urinary tract in infancy and childhood starts with ultrasound with the exception of severe abdominal trauma which is investigated by computertomography. The decision 'normal or abnormal' is possible using ultrasound in the most pediatric cases. The diagnostic value and significance of ultrasound in infancy and childhood is far better than in general radiology because of the higher resolution of the high-frequency units taken. The result of the ultrasound examination should be the basis for the following imaging procedures. We will describe diagnostic flow charts starting with three important clinical symptoms: Prenatal pathology, urinary tract obstruction and urinary tract infection. (orig.) [de

  11. Technical diagnostics of steam turbines

    International Nuclear Information System (INIS)

    Vlckova, B.; Drahy, J.

    1987-01-01

    This paper deals with practical experience in application of technical diagnostics methods to steam turbines, in particular using pedestal and shaft vibration measurements as well as estimation of bearing metal temperature and ultrasound emission signals. An estimation of effectiveness of the diagnostics methods used is given on the basis of experimental investigations made on a 30-MW turbine. (author)

  12. Laparoscopic ultrasound and gastric cancer

    Science.gov (United States)

    Dixon, T. Michael; Vu, Huan

    2001-05-01

    The management of gastrointestinal malignancies continues to evolve with the latest available therapeutic and diagnostic modalities. There are currently two driving forces in the management of these cancers: the benefits of minimally invasive surgery so thoroughly demonstrated by laparoscopic surgery, and the shift toward neoadjuvant chemotherapy for upper gastrointestinal cancers. In order to match the appropriate treatment to the disease, accurate staging is imperative. No technological advances have combined these two needs as much as laparascopic ultrasound to evaluate the liver and peritoneal cavity. We present a concise review of the latest application of laparoscopic ultrasound in management of gastrointestinal malignancy.

  13. Classification and management of gynecomastia: defining the role of ultrasound-assisted liposuction.

    Science.gov (United States)

    Rohrich, Rod J; Ha, Richard Y; Kenkel, Jeffrey M; Adams, William P

    2003-02-01

    Gynecomastia, or excessive male breast development, has an incidence of 32 to 65 percent in the male population. This condition has important physical and psychological impacts. Advances in elucidating the pathophysiology of gynecomastia have been made, though understanding remains limited. Recommendations for evaluation and workup have varied and are often arbitrary. A diagnostic algorithm is suggested, with emphasis on a comprehensive history, physical examination, and minimizing unnecessary diagnostic testing. Medical management has had limited success; surgical therapy, primarily through excisional techniques, has been the accepted standard. Although effective, excisional techniques subject patients to large, visible scars. Ultrasound-assisted liposuction has recently emerged as a safe and effective method for the treatment of gynecomastia. It is particularly efficient in the removal of the dense, fibrous male breast tissue while offering advantages in minimal external scarring. A new system of classification and graduated treatment is proposed, based on glandular versus fibrous hypertrophy and degree of breast ptosis (skin excess). The authors' series of 61 patients with gynecomastia from 1987 to 2000 at the University of Texas Southwestern Department of Plastic Surgery demonstrated an overall success rate of 86.9 percent using suction-assisted lipectomy (1987 to 1997) and ultrasound-assisted liposuction (1997 to 2000). The authors have found ultrasound-assisted liposuction to be effective in treating most grades of gynecomastia. Excisional techniques are reserved for severe gynecomastia with significant skin excess after attempted ultrasound-assisted liposuction.

  14. Digital breast tomosynthesis versus mammography and breast ultrasound: a multireader performance study

    International Nuclear Information System (INIS)

    Thibault, Fabienne; Malhaire, Caroline; Tardivon, Anne; Dromain, Clarisse; Balleyguier, Corinne S.; Breucq, Catherine; Steyaert, Luc; Baldan, Enrica; Drevon, Harir

    2013-01-01

    To compare the diagnostic performance of single-view breast tomosynthesis (BT) with that of dual-view mammography (MX); to assess the benefit of adding the craniocaudal (CC) mammographic view to BT, and of adding BT to MX plus breast ultrasound, considered to be the reference work-up. One hundred and fifty-five consenting patients with unresolved mammographic and/or ultrasound findings or breast symptoms underwent conventional work-up plus mediolateral oblique-view BT of the affected breast. The final study set in 130 patients resulted in 55 malignant and 76 benign and normal cases. Seven breast radiologists rated the cases through five sequential techniques using a BIRADS-based scale: MX, MX + ultrasound, MX + ultrasound + BT, BT, BT + MX(CC). Multireader, multicase receiver operating characteristic (ROC) analysis was performed and performance of the techniques was assessed from the areas under ROC curves. The performance of BT and of BT + MX(CC) was tested versus MX; the performance of MX + ultrasound + BT tested versus MX + ultrasound. Tomosynthesis was found to be non-inferior to mammography. BT + MX(CC) did not appear to be superior to MX, and MX + ultrasound + BT not superior to MX + ultrasound. Overall, none of the five techniques tested outperformed the others. Further clinical studies are needed to clarify the role of BT as a substitute for traditional work-up in the diagnostic environment. (orig.)

  15. Studies of nonlinear ultrasound propagation: safety considerations in the use of ultrasound for medical diagnosis - nonlinear propagation

    International Nuclear Information System (INIS)

    Egerton, B.; Barnett, S.; Vella, G.

    1994-01-01

    Diagnostic ultrasound is an established imaging modality without any documented harmful effects. New developments such as pulsed Doppler and intracavity investigations may result in increases in ultrasound exposures which could cause harm. Thermal mechanisms and cavitation may become relevant sources of bioeffects. The preliminary study described here investigates the distribution and amplitude of harmonics generated through nonlinear propagation of ultrasound in water. Knowledge of harmonic attenuation will help predict sites of enhanced heating and enable accurate modelling of clinical situations. This presentation is concerned with thermal safety guidelines, their relationship to a typical ultrasound beam profile for a single, medium focussed, transducer operating in water and possible sites of enhanced heating due to nonlinear propagation effects. Measurements were made of the amplitudes of the harmonics generated by the nonlinear propagation of ultrasound in water. The amplitudes of the harmonics were detected up to frequencies of 35 MHz and displayed using Fast Fourier Transform facilities within the oscilloscope. The nonlinearity parameter of the ultrasonic waveforms has been identified as an important factor in thermal effects of ultrasound interactions. The appearance of nonlinear distortion is shown to be dependant on the peak compressional pressure and distance from the ultrasound source. 20 refs., 2 figs

  16. Evolution of Robot-assisted ultrasound-guided breast biopsy systems

    Directory of Open Access Journals (Sweden)

    Mustafa Z. Mahmoud

    2018-01-01

    Full Text Available Robot-assisted ultrasound-guided breast biopsy combines ultrasound (US imaging with a robotic system for medical interventions. This study was designed to provide a literature review of a robotic US-guided breast biopsy system to delineate its efficacious impact on current medical practice. In addition, the strengths and limitations of this approach were also addressed. Articles published in the English language between 2000 and 2016 were appraised in this review. A wide range of systems that bind robotics with US imaging and guided breast biopsy were examined in this article. The fundamental safety and real-time imaging capabilities of US, together with the accuracy and maneuverability of robotic devices, is clearly an effective association with unmatched capabilities. Numerous experimental systems have obvious benefits over old-fashioned techniques, and the future of robot-assisted US-guided breast biopsy will be characterized by increasing levels of automation, and they hold tremendous possibility to impact doctor achievement, patient recovery, and clinical management.

  17. Ultrasound determination of rotator cuff tear repairability

    Science.gov (United States)

    Tse, Andrew K; Lam, Patrick H; Walton, Judie R; Hackett, Lisa

    2015-01-01

    Background Rotator cuff repair aims to reattach the torn tendon to the greater tuberosity footprint with suture anchors. The present study aimed to assess the diagnostic accuracy of ultrasound in predicting rotator cuff tear repairability and to assess which sonographic and pre-operative features are strongest in predicting repairability. Methods The study was a retrospective analysis of measurements made prospectively in a cohort of 373 patients who had ultrasounds of their shoulder and underwent rotator cuff repair. Measurements of rotator cuff tear size and muscle atrophy were made pre-operatively by ultrasound to enable prediction of rotator cuff repairability. Tears were classified following ultrasound as repairable or irreparable, and were correlated with intra-operative repairability. Results Ultrasound assessment of rotator cuff tear repairability has a sensitivity of 86% (p tear size (p tear size ≥4 cm2 or anteroposterior tear length ≥25 mm indicated an irreparable rotator cuff tear. Conclusions Ultrasound assessment is accurate in predicting rotator cuff tear repairability. Tear size or anteroposterior tear length and age were the best predictors of repairability. PMID:27582996

  18. Thioaptamer Diagnostic System, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — AM Biotechnologies (AM) will develop a diagnostic system in response to SBIR Topic X10.01 Reusable Diagnostic Lab Technology that will simultaneously detect and...

  19. Ultrasound assisted evaluation of chest pain in the emergency department.

    Science.gov (United States)

    Colony, M Deborah; Edwards, Frank; Kellogg, Dylan

    2018-04-01

    Chest pain is a commonly encountered emergency department complaint, with a broad differential including several life-threatening possible conditions. Ultrasound-assisted evaluation can potentially be used to rapidly and accurately arrive at the correct diagnosis. We propose an organized, ultrasound assisted evaluation of the patient with chest pain using a combination of ultrasound, echocardiography and clinical parameters. Basic echo techniques which can be mastered by residents in a short time are used plus standardized clinical questions and examination. Information is kept on a checklist. We hypothesize that this will result in a quicker, more accurate evaluation of chest pain in the ED leading to timely treatment and disposition of the patient, less provider anxiety, a reduction in the number of diagnostic errors, and the removal of false assumptions from the diagnostic process. Copyright © 2017 Elsevier Inc. All rights reserved.

  20. Obstetrical ultrasound data-base management system by using personal computer

    International Nuclear Information System (INIS)

    Jeon, Hae Jeong; Park, Jeong Hee; Kim, Soo Nyung

    1993-01-01

    A computer program which performs obstetric calculations on Clipper Language using the data from ultrasonography was developed for personal computer. It was designed for fast assessment of fetal development, prediction of gestational age, and weight from ultrasonographic measurements which included biparietal diameter, femur length, gestational sac, occipito-frontal diameter, abdominal diameter, and etc. The Obstetrical-Ultrasound Data-Base Management System was tested for its performance. The Obstetrical-Ultrasound Data-Base Management System was very useful in patient management with its convenient data filing, easy retrieval of previous report, prompt but accurate estimation of fetal growth and skeletal anomaly and production of equation and growth curve for pregnant women

  1. Quantitative evaluation of contrast-enhanced ultrasound after intravenous administration of a microbubble contrast agent for differentiation of benign and malignant thyroid nodules: assessment of diagnostic accuracy.

    Science.gov (United States)

    Nemec, Ursula; Nemec, Stefan F; Novotny, Clemens; Weber, Michael; Czerny, Christian; Krestan, Christian R

    2012-06-01

    To investigate the diagnostic accuracy, through quantitative analysis, of contrast-enhanced ultrasound (CEUS), using a microbubble contrast agent, in the differentiation of thyroid nodules. This prospective study enrolled 46 patients with solitary, scintigraphically non-functional thyroid nodules. These patients were scheduled for surgery and underwent preoperative CEUS with pulse-inversion harmonic imaging after intravenous microbubble contrast medium administration. Using histology as a standard of reference, time-intensity curves of benign and malignant nodules were compared by means of peak enhancement and wash-out enhancement relative to the baseline intensity using a mixed model ANOVA. ROC analysis was performed to assess the diagnostic accuracy in the differentiation of benign and malignant nodules on CEUS. The complete CEUS data of 42 patients (31/42 [73.8%] benign and 11/42 [26.2%] malignant nodules) revealed a significant difference (P benign and malignant nodules. Furthermore, based on ROC analysis, CEUS demonstrated sensitivity of 76.9%, specificity of 84.8% and accuracy of 82.6%. Quantitative analysis of CEUS using a microbubble contrast agent allows the differentiation of benign and malignant thyroid nodules and may potentially serve, in addition to grey-scale and Doppler ultrasound, as an adjunctive tool in the assessment of patients with thyroid nodules. • Contrast-enhanced ultrasound (CEUS) helps differentiate between benign and malignant thyroid nodules. • Quantitative CEUS analysis yields sensitivity of 76.9% and specificity of 84.8%. • CEUS may be a potentially useful adjunct in assessing thyroid nodules.

  2. WFUMB Position Paper. Learning Gastrointestinal Ultrasound

    DEFF Research Database (Denmark)

    Atkinson, Nathan S S; Bryant, Robert V; Dong, Yi

    2016-01-01

    Gastrointestinal ultrasound (GIUS) is an ultrasound application that has been practiced for more than 30 years. Recently, GIUS has enjoyed a resurgence of interest, and there is now strong evidence of its utility and accuracy as a diagnostic tool for multiple indications. The method of learning...... GIUS is not standardised and may incorporate mentorship, didactic teaching and e-learning. Simulation, using either low- or high-fidelity models, can also play a key role in practicing and honing novice GIUS skills. A course for training as well as establishing and evaluating competency in GIUS...

  3. Ultrasound update: Where we've been, where we're heading

    International Nuclear Information System (INIS)

    Rodriguez, J.

    1987-01-01

    The roots of diagnostic ultrasound are less than 30 years old, yet the technological advances have far surpassed the expectations of its founding fathers. The boom age of ultrasound, the 1970s, was characterized by new equipment, procedures, and educational opportunities. The growth of ultrasound has temporarily leveled out, but a new age of technological advances is again visible on the horizon. This lecture looks back to the impact of the 1970s and the new boom of the 1980s

  4. High-intensity ultrasound production of Maillard reaction flavor compounds in a cysteine-xylose model system.

    Science.gov (United States)

    Ong, Olivia X H; Seow, Yi-Xin; Ong, Peter K C; Zhou, Weibiao

    2015-09-01

    Application of high intensity ultrasound has shown potential in the production of Maillard reaction odor-active flavor compounds in model systems. The impact of initial pH, sonication duration, and ultrasound intensity on the production of Maillard reaction products (MRPs) by ultrasound processing in a cysteine-xylose model system were evaluated using Response Surface Methodology (RSM) with a modified mathematical model. Generation of selected MRPs, 2-methylthiophene and tetramethyl pyrazine, was optimal at an initial pH of 6.00, accompanied with 78.1 min of processing at an ultrasound intensity of 19.8 W cm(-2). However, identification of volatiles using gas chromatography-mass spectrometry (GC/MS) revealed that ultrasound-assisted Maillard reactions generated fewer sulfur-containing volatile flavor compounds as compared to conventional heat treatment of the model system. Likely reasons for this difference in flavor profile include the expulsion of H2S due to ultrasonic degassing and inefficient transmission of ultrasonic energy. Copyright © 2015 Elsevier B.V. All rights reserved.

  5. Droplets, Bubbles and Ultrasound Interactions.

    Science.gov (United States)

    Shpak, Oleksandr; Verweij, Martin; de Jong, Nico; Versluis, Michel

    2016-01-01

    The interaction of droplets and bubbles with ultrasound has been studied extensively in the last 25 years. Microbubbles are broadly used in diagnostic and therapeutic medical applications, for instance, as ultrasound contrast agents. They have a similar size as red blood cells, and thus are able to circulate within blood vessels. Perfluorocarbon liquid droplets can be a potential new generation of microbubble agents as ultrasound can trigger their conversion into gas bubbles. Prior to activation, they are at least five times smaller in diameter than the resulting bubbles. Together with the violent nature of the phase-transition, the droplets can be used for local drug delivery, embolotherapy, HIFU enhancement and tumor imaging. Here we explain the basics of bubble dynamics, described by the Rayleigh-Plesset equation, bubble resonance frequency, damping and quality factor. We show the elegant calculation of the above characteristics for the case of small amplitude oscillations by linearizing the equations. The effect and importance of a bubble coating and effective surface tension are also discussed. We give the main characteristics of the power spectrum of bubble oscillations. Preceding bubble dynamics, ultrasound propagation is introduced. We explain the speed of sound, nonlinearity and attenuation terms. We examine bubble ultrasound scattering and how it depends on the wave-shape of the incident wave. Finally, we introduce droplet interaction with ultrasound. We elucidate the ultrasound-focusing concept within a droplets sphere, droplet shaking due to media compressibility and droplet phase-conversion dynamics.

  6. Toward a real-time system for temporal enhanced ultrasound-guided prostate biopsy.

    Science.gov (United States)

    Azizi, Shekoofeh; Van Woudenberg, Nathan; Sojoudi, Samira; Li, Ming; Xu, Sheng; Abu Anas, Emran M; Yan, Pingkun; Tahmasebi, Amir; Kwak, Jin Tae; Turkbey, Baris; Choyke, Peter; Pinto, Peter; Wood, Bradford; Mousavi, Parvin; Abolmaesumi, Purang

    2018-03-27

    We have previously proposed temporal enhanced ultrasound (TeUS) as a new paradigm for tissue characterization. TeUS is based on analyzing a sequence of ultrasound data with deep learning and has been demonstrated to be successful for detection of cancer in ultrasound-guided prostate biopsy. Our aim is to enable the dissemination of this technology to the community for large-scale clinical validation. In this paper, we present a unified software framework demonstrating near-real-time analysis of ultrasound data stream using a deep learning solution. The system integrates ultrasound imaging hardware, visualization and a deep learning back-end to build an accessible, flexible and robust platform. A client-server approach is used in order to run computationally expensive algorithms in parallel. We demonstrate the efficacy of the framework using two applications as case studies. First, we show that prostate cancer detection using near-real-time analysis of RF and B-mode TeUS data and deep learning is feasible. Second, we present real-time segmentation of ultrasound prostate data using an integrated deep learning solution. The system is evaluated for cancer detection accuracy on ultrasound data obtained from a large clinical study with 255 biopsy cores from 157 subjects. It is further assessed with an independent dataset with 21 biopsy targets from six subjects. In the first study, we achieve area under the curve, sensitivity, specificity and accuracy of 0.94, 0.77, 0.94 and 0.92, respectively, for the detection of prostate cancer. In the second study, we achieve an AUC of 0.85. Our results suggest that TeUS-guided biopsy can be potentially effective for the detection of prostate cancer.

  7. The 'humble' bubble: Contrast-enhanced ultrasound

    International Nuclear Information System (INIS)

    Marshall, Gill; Sykes, Anne; Berry, Jonathan; Jonker, Leon

    2011-01-01

    The use of contrast-enhanced ultrasound (CEUS) is increasing within the field of medical imaging. Ultrasonic contrast agent (UCA) contain gas microbubbles similar in size to red corpuscles which provide highly reflective interfaces, enabling dynamic demonstration of echogenic streams of the contrast within the anatomical area of interest on real-time grey scale ultrasound. Longevity of the microbubbles has been improved by changing their composition. The application of CEUS in the UK continues to grow, bringing it into territories historically occupied by computerised tomography (CT) scanning and magnetic resonance imaging (MRI). Hence, the role of CEUS may be of interest to all diagnostic imaging practitioners. Here we summarise the mode of action and use of CEUS, and its role within a range of applications. The potential risks of CEUS are compared to other contrast-enhanced imaging techniques. The benefits of CEUS and its implications for diagnostic imaging practice are also covered.

  8. [Relevance of contrast ultrasound with microbubbles in vascular medecine].

    Science.gov (United States)

    Erdmann, Andreas; Ney, Barbara; Alatri, Adriano; Calanca, Luca; Mazzolai, Lucia

    2016-12-07

    Application of ultrasound contrast media has become a standard in diagnostic imaging in cardiology and in the characterization of focal lesions in multiple organs, especially of the liver. In the past years there was a growing body of evidence for their usefulness in vascular medicine. The development of contrast media, microbubbles with a stabilizing envelope and filled with gaz, small enough to pass through pulmonary capillaries made real-time imaging of organ perfusion possible. Ultrasound contrast media are rapidly eliminated by exhalation and can safely be administered to patients with renal failure. The objective of this review is to describe the basic principles of ultrasound contrast imaging and to inform about vascular applications of contrast ultrasound.

  9. A novel fluoride anion modified gelatin nanogel system for ultrasound-triggered drug release.

    Science.gov (United States)

    Wu, Daocheng; Wan, Mingxi

    2008-01-01

    Controlled drug release, especially tumor-targeted drug release, remains a great challenge. Here, we prepare a novel fluoride anion-modified gelatin nanogel system and investigate its characteristics of ultrasound-triggered drug release. Adriamycin gelatin nanogel modified with fluoride anion (ADM-GNMF) was prepared by a modified co-precipitation method with fluoride anion and sodium sulfate. The loading and encapsulation efficiency of the anti-neoplastic agent adriamycin (ADM) were measured by high performance liquid chromatography (HPLC). The size and shape of ADM-GNMF were determined by electron microscopy and photo-correlation spectroscopy. The size distribution and drug release efficiency of ADM-GNMF, before and after sonication, were measured by two designed measuring devices that consisted of either a submicron particle size analyzer and an ultrasound generator as well as an ultrasound generator, automatic sampler, and HPLC. The ADM-GNMF was stable in solution with an average diameter of 46+/-12 nm; the encapsulation and loading efficiency of adriamycin were 87.2% and 6.38%, respectively. The ultrasound-triggered drug release and size change were most efficient at a frequency of 20 kHz, power density of 0.4w/cm2, and a 1~2 min duration. Under this ultrasound-triggered condition, 51.5% of drug in ADM-GNMF was released within 1~2 min, while the size of ADM-GNMF changed from 46 +/- 12 nm to 1212 +/- 35 nm within 1~2 min of sonication and restored to its previous size in 2~3 min after the ultrasound stopped. In contrast, 8.2% of drug in ADM-GNMF was released within 2~3 min without sonication, and only negligible size changes were found. The ADM-GNMF system efficiently released the encompassed drug in response to ultrasound, offering a novel and promising controlled drug release system for targeted therapy for cancer or other diseases.

  10. Diagnostic and prognostic values of standard and dynamic ultrasound in early detection and treatment of developmental hip deformity

    Directory of Open Access Journals (Sweden)

    Pajić Miloš

    2007-01-01

    Full Text Available Introduction A clinical examination of a newborn infant is indispensable, but certainly insufficient for a diagnosis of developmental deformity of the hip (DDH to be made. The use of the ultrasound in the diagnostics of DDH, beside the visualization and making the respective clinical findings objective, made possible verification (still without a distinction of the tissues of the two basic categories of the primary condition of a newborn baby hips. Objective The purpose of this study was to find out the optimal methodological procedure for the early detection of DDH in newborn infants and suckling. Method During 2002 and 2003, at the Neonatal Department of the Clinic for Gynecology and Obstetrics, Novi Sad, as well as at the Institute for Orthopedic Surgery "Banjica" Belgrade, there were 4016 newborn infants examined, i.e. 8032 hips clinically and by ultrasound. The standard Graf’s methodological procedure was applied completely, supplemented by the dynamic examination by pushing back and stretching femora along, that is by the techniques of Couture and Harcke. Results In order to categorize the condition of the hip of a newborn infant, the sonographic classification of R. Graaf, Th. Harcke and D. Pajić was used. The ultrasound analysis demonstrated a frequency of the sonotype Ia in 552 (13.08% of the newborn infants, the sonotype Ib in 2934 (73.00%, the sonotype IIa+ in 481 (11.97% and the pathological cases with sonotypes IIg 42 (1.04%, IId 17 (0.42%, IIIa 15 (0.37% and IV 5 (0.12%. The total number of unstable critical, discentering and discentered cases of DDH was 79 (1.95%. The incidence of DDH was three times more frequent in girls, mostly bilateral; when unilateral, it was more frequent in the left one. The results of the early treatment were uniformly excellent, but in two cases there was established osteochondritis of the first degree (Pavlik’s harness 1, Von Rosen’s splint 1. Conclusion It has been proven that the clinical

  11. Ultrasound-guided image fusion with computed tomography and magnetic resonance imaging. Clinical utility for imaging and interventional diagnostics of hepatic lesions

    International Nuclear Information System (INIS)

    Clevert, D.A.; Helck, A.; Paprottka, P.M.; Trumm, C.; Reiser, M.F.; Zengel, P.

    2012-01-01

    Abdominal ultrasound is often the first-line imaging modality for assessing focal liver lesions. Due to various new ultrasound techniques, such as image fusion, global positioning system (GPS) tracking and needle tracking guided biopsy, abdominal ultrasound now has great potential regarding detection, characterization and treatment of focal liver lesions. Furthermore, these new techniques will help to improve the clinical management of patients before and during interventional procedures. This article presents the principle and clinical impact of recently developed techniques in the field of ultrasound, e.g. image fusion, GPS tracking and needle tracking guided biopsy and discusses the results based on a feasibility study on 20 patients with focal hepatic lesions. (orig.) [de

  12. Chronic pelvic pain: how does noninvasive imaging compare with diagnostic laparoscopy?

    Science.gov (United States)

    Tirlapur, Seema A; Daniels, Jane P; Khan, Khalid S

    2015-12-01

    Chronic pelvic pain (CPP) has an annual prevalence of 38/1000 in the UK, with coexisting pathologies often present. Diagnostic laparoscopy has long been the gold standard diagnostic test, but with up to 40% showing no abnormality, we explore the value of noninvasive imaging, such as pelvic ultrasound and MRI. A literature review from inception until January 2015 of the following databases: PubMed, MEDLINE, Cumulative Index to Nursing and Allied Health Literature, Excerpta Medica database, and System for Information on Grey Literature in Europe were performed to identify published studies assessing the usefulness of ultrasound, MRI, and laparoscopy in the diagnosis of CPP. Three studies (194 women) addressed their comparative performance in patients with endometriosis, showing the sensitivity of ultrasound ranged between 58 and 88.5%; MRI was 56-91.5% and in the one study using histology as its reference standard, the sensitivity of laparoscopy was 85.7%. Noninvasive imaging has the additional benefit of being well tolerated, safer, and cheaper than surgery. CPP, by nature of its multifactorial causation, can be difficult to manage and often requires a multidisciplinary team. Ultrasound and MRI may provide information about the presence or lack of abnormality, which would allow general practitioners or office gynaecologists to initiate treatment and think about surgery as a second-line investigative tool.

  13. Ultrasound of the acute abdomen performed by surgeons in training

    DEFF Research Database (Denmark)

    Eiberg, J.P.; Grantcharov, T.P.; Eriksen, J.R.

    2008-01-01

    , specificity and kappa-agreement of the surgeon performed ultrasound examination was 1.00 (0.77-1.00), 0.96 (0.79-0.99), 0.94 (0.3-1.00) and 0.40 (0.12-0.77), 0.97 (0.83-0.99), 0.44 (0.00-0.96); respectively. Visualization of the common bile duct was poor having 73% non-diagnostic surgeon-performed ultrasound...... perform valid abdominal ultrasound examinations of patients referred with acute abdominal pain. METHODS: Patients referred with acute abdominal pain had an ultrasound examination by a surgeon in training as well as by an experienced consultant radiologist whose results served as the gold standard. All...... participating surgeons were without any pre-existing ultrasound experience and received one hour of introduction to abdominal ultrasound. RESULTS: Thirty patients underwent 40 surgeon performed and 30 radiologist performed ultrasound examinations. Regarding gallstone and cholecholecystitis the sensitivity...

  14. A Portable Ultrasound System for Non-Invasive Ultrasonic Neuro-Stimulation.

    Science.gov (United States)

    Qiu, Weibao; Zhou, Juan; Chen, Yan; Su, Min; Li, Guofeng; Zhao, Huixia; Gu, Xianyi; Meng, De; Wang, Congzhi; Xiao, Yang; Lam, Kwok Ho; Dai, Jiyan; Zheng, Hairong

    2017-12-01

    Fundamental insights into the function of the neural circuits often follows from the advances in methodologies and tools for neuroscience. Electrode- and optical- based stimulation methods have been used widely for neuro-modulation with high resolution. However, they are suffering from inherent invasive surgical procedure. Ultrasound has been proved as a promising technology for neuro-stimulation in a non-invasive manner. However, no portable ultrasound system has been developed particularly for neuro-stimulation. The utilities used currently are assembled by traditional functional generator, power amplifier, and general transducer, therefore, resulting in lack of flexibility. This paper presents a portable system to achieve ultrasonic neuro-stimulation to satisfy various studies. The system incorporated a high voltage waveform generator and a matching circuit that were optimized for neuro-stimulation. A new switching mode power amplifier was designed and fabricated. The noise generated by the power amplifier was reduced (about 30 dB), and the size and weight were smaller in contrast with commercial equipment. In addition, a miniaturized ultrasound transducer was fabricated using Pb(Mg 1/3 Nb 2/3 )O 3 -PbTiO 3 (PMN-PT) 1-3 composite single crystal for the improved ultrasonic performance. The spatial peak temporal average pressure was higher than 250 kPa in the range of 0.5-5 MHz. In vitro and in vivo studies were conducted to show the performance of the system.

  15. Diagnostic Performance and Confidence of Contrast-Enhanced Ultrasound in the Differential Diagnosis of Cystic and Cysticlike Liver Lesions.

    Science.gov (United States)

    Corvino, Antonio; Catalano, Orlando; Corvino, Fabio; Sandomenico, Fabio; Petrillo, Antonella

    2017-09-01

    The aims of this study were to assess the diagnostic performance of contrast-enhanced ultrasound (CEUS) in the characterization of atypical cystic and cysticlike focal liver lesions in comparison with conventional US and to determine whether the use of CEUS can reduce the need for further diagnostic workup. In a 3-year period 48 patients with 50 atypical cystic and cysticlike lesions found at conventional US underwent CEUS. Diagnostic confirmation was obtained in cytohistopathologic examinations, with other imaging modalities, and in follow-up. Overall, there were 24 cystic lesions and 26 cysticlike solid lesions, specifically 32 benign and 18 malignant lesions. The conventional US and CEUS images and cine loops were reviewed by two blinded readers independently. Sensitivity, specificity, area under the ROC curve (A z ), and interobserver agreement were calculated. Diagnostic performance improved after review of CEUS examinations by both readers (conventional US A z = 0.781 vs 0.972; CEUS A z = 0.734 vs 0.957). Interreader agreement increased, although slightly (conventional US weighted κ = 0.894; CEUS weighted κ = 0.953). In terms of differential diagnosis, the occurrence of correctly characterized lesions increased after CEUS for both readers (reader 1, 62% to 98%; reader 2, 56% to 96%). The development of low-acoustic-power CEUS has made it possible to identify several imaging features of cystic and cysticlike focal liver lesions that, in association with history and clinical findings, may help to correctly characterize them. Our data indicate the usefulness of CEUS in the evaluation of patients with these lesions.

  16. Case-Based Fault Diagnostic System

    International Nuclear Information System (INIS)

    Mohamed, A.H.

    2014-01-01

    Nowadays, case-based fault diagnostic (CBFD) systems have become important and widely applied problem solving technologies. They are based on the assumption that “similar faults have similar diagnosis”. On the other hand, CBFD systems still suffer from some limitations. Common ones of them are: (1) failure of CBFD to have the needed diagnosis for the new faults that have no similar cases in the case library. (2) Limited memorization when increasing the number of stored cases in the library. The proposed research introduces incorporating the neural network into the case based system to enable the system to diagnose all the faults. Neural networks have proved their success in the classification and diagnosis problems. The suggested system uses the neural network to diagnose the new faults (cases) that cannot be diagnosed by the traditional CBR diagnostic system. Besides, the proposed system can use the another neural network to control adding and deleting the cases in the library to manage the size of the cases in the case library. However, the suggested system has improved the performance of the case based fault diagnostic system when applied for the motor rolling bearing as a case of study

  17. Use of Ultrasound Elastography in the Assessment of the Musculoskeletal System

    International Nuclear Information System (INIS)

    Paluch, Łukasz; Nawrocka-Laskus, Ewa; Wieczorek, Janusz; Mruk, Bartosz; Frel, Małgorzata; Walecki, Jerzy

    2016-01-01

    This article presents possible applications of ultrasound elastography in musculoskeletal imaging based on the available literature, as well as the possibility of extending indications for the use of elastography in the future. Ultrasound elastography (EUS) is a new method that shows structural changes in tissues following application of physical stress. Elastography techniques have been widely used to assess muscles and tendons in vitro since the early parts of the twentieth century. Only recently with the advent of new technology and creation of highly specialized ultrasound devices, has elastography gained widespread use in numerous applications. The authors performed a search of the Medline/PubMed databases for original research and reviewed publications on the application of ultrasound elastography for musculoskeletal imaging. All publications demonstrate possible uses of ultrasound elastography in examinations of the musculoskeletal system. The most widely studied areas include the muscles, tendons and rheumatic diseases. There are also reports on the employment in vessel imaging. The main limitation of elastography as a technique is above all the variability of applied pressure during imaging, which is operator-dependent. It would therefore be reasonable to provide clear guidelines on the technique applied, as well as clear indications for performing the test. It is important to develop methods for creating artifact-free, closed-loop, compression-decompression cycles. The main advantages include cost-effectiveness, short duration of the study, non-invasive nature of the procedure, as well as a potentially broader clinical availability. There are no clear guidelines with regard to indications as well as examination techniques. Ultrasound elastography is a new and still poorly researched method. We conclude, however, that it can be widely used in the examinations of musculoskeletal system. Therefore, it is necessary to conduct large, multi-center studies to

  18. [Ultrasound of spleen and retroperitoneum].

    Science.gov (United States)

    Salcedo Joven, I; Segura-Grau, A; Díaz Rodríguez, N; Segura-Cabral, J M

    2016-09-01

    Ultrasound provides data of extremely great value when studying spleen pathology, being diagnostic in splenomegaly and splenic trauma, as well as offering a good approach to the diagnosis of both benign and malignant focal pathology, particularly lymphoma. However, for the evaluation of adrenal and retroperitoneal diseases, other techniques such as CT or MRI are more suitable, even though ultrasound is still an excellent screening and monitoring method, as well as being useful in non-invasive therapeutic approaches. Copyright © 2014 Sociedad Española de Médicos de Atención Primaria (SEMERGEN). Publicado por Elsevier España, S.L.U. All rights reserved.

  19. Accuracy and safety of ward based pleural ultrasound in the Australian healthcare system.

    Science.gov (United States)

    Hammerschlag, Gary; Denton, Matthew; Wallbridge, Peter; Irving, Louis; Hew, Mark; Steinfort, Daniel

    2017-04-01

    Ultrasound has been shown to improve the accuracy and safety of pleural procedures. Studies to date have been performed in large, specialized units, where pleural procedures are performed by a small number of highly specialized physicians. There are no studies examining the safety and accuracy of ultrasound in the Australian healthcare system where procedures are performed by junior doctors with a high staff turnover. We performed a retrospective review of the ultrasound database in the Respiratory Department at the Royal Melbourne Hospital to determine accuracy and complications associated pleural procedures. A total of 357 ultrasounds were performed between October 2010 and June 2013. Accuracy of pleural procedures was 350 of 356 (98.3%). Aspiration of pleural fluid was successful in 121 of 126 (96%) of patients. Two (0.9%) patients required chest tube insertion for management of pneumothorax. There were no recorded pleural infections, haemorrhage or viscera puncture. Ward-based ultrasound for pleural procedures is safe and accurate when performed by appropriately trained and supported junior medical officers. Our findings support this model of pleural service care in the Australian healthcare system. © 2016 Asian Pacific Society of Respirology.

  20. Psychometric perspectives on diagnostic systems

    NARCIS (Netherlands)

    Borsboom, D.

    2008-01-01

    The author identifies four conceptualizations of the relation between symptoms and disorders as utilized in diagnostic systems such as the Diagnostic and Statistical Manual of Mental Disorders, Fourth Edition (DSM-IV; American Psychiatric Association, 1994): A constructivist perspective, which holds

  1. Detection of vascularity in wrist tenosynovitis: power doppler ultrasound compared with contrast-enhanced grey-scale ultrasound.

    Science.gov (United States)

    Klauser, Andrea S; Franz, Magdalena; Arora, Rohit; Feuchtner, Gudrun M; Gruber, Johann; Schirmer, Michael; Jaschke, Werner R; Gabl, Markus F

    2010-01-01

    We sought to assess vascularity in wrist tenosynovitis by using power Doppler ultrasound (PDUS) and to compare detection of intra- and peritendinous vascularity with that of contrast-enhanced grey-scale ultrasound (CEUS). Twenty-six tendons of 24 patients (nine men, 15 women; mean age ± SD, 54.4 ± 11.8 years) with a clinical diagnosis of tenosynovitis were examined with B-mode ultrasonography, PDUS, and CEUS by using a second-generation contrast agent, SonoVue (Bracco Diagnostics, Milan, Italy) and a low-mechanical-index ultrasound technique. Thickness of synovitis, extent of vascularized pannus, intensity of peritendinous vascularisation, and detection of intratendinous vessels was incorporated in a 3-score grading system (grade 0 to 2). Interobserver variability was calculated. With CEUS, a significantly greater extent of vascularity could be detected than by using PDUS (P < 0.001). In terms of peri- and intratendinous vessels, CEUS was significantly more sensitive in the detection of vascularization compared with PDUS (P < 0.001). No significant correlation between synovial thickening and extent of vascularity could be found (P = 0.089 to 0.097). Interobserver reliability was calculated to be excellent when evaluating the grading score (κ = 0.811 to 1.00). CEUS is a promising tool to detect tendon vascularity with higher sensitivity than PDUS by improved detection of intra- and peritendinous vascularity.

  2. Imaging of the peripheral vascular system

    International Nuclear Information System (INIS)

    Gould, S.A.; Pond, G.D.; Pinsky, S.; Moss, G.S.; Srikantaswamy, S.; Ryo, U.Y.

    1984-01-01

    This book is limited neither to the peripheral vascular system nor to diagnostic imaging techniques. Its 18 chapters cover nonimaging blood-flow techniques (Doppler ultrasound, plethysmography) as well as noninvasive and invasive imaging techniques (ultrasound, computed tomography, radionuclide digital-subtraction angiography, and contrast angiography). These are applied not only to the peripheral vascular system but also to the aorta and vena cava

  3. Duplex ultrasound evidence of fat embolism syndrome

    Directory of Open Access Journals (Sweden)

    Abdallah Naddaf, MD

    2016-12-01

    Full Text Available Fat embolism syndrome is a potentially fatal disease process most commonly associated with long-bone and pelvic fractures. Reports describing ultrasound evidence of fat emboli are restricted to echocardiography. We propose a new objective finding on venous duplex ultrasound imaging of the lower extremities as a useful diagnostic criterion by presenting the case reports of two patients with acute long-bone fractures, possibly leading to earlier orthopedic fixation and allocation of resources to those patients at higher risk of fat embolism syndrome.

  4. Comparison of diagnostic yield of endoscopic ultrasound-guided fine-needle aspiration cytology and cell block in solid lesions

    Directory of Open Access Journals (Sweden)

    Avinash Bhat Balekuduru

    2017-01-01

    Full Text Available Background and Aim: Endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA is a procedure of choice for the diagnostic evaluation of submucosal and periluminal lesions. Tissue sample can be obtained by EUS-FNA cytology (FNAC or cell block (CB. The aim of the present study is to compare diagnostic yield of EUS-FNA CB and cytology in the absence of onsite pathologist following a protocol-based EUS-FNA approach in solid lesions. Patients and Methods: Participants who underwent EUS-FNA at our center for solid submucosal or periluminal lesions (pancreas, lymph node, and liver between 2014 and 2016 were included, retrospectively. The indication for the procedure along with the clinical and other investigation details and the final etiological diagnosis were recorded on uniform structured data forms. The diagnostic yield of cytology and CB were compared using McNemar's test. The P < 0.05 was considered statistically significant. Results: EUS-FNA for solid lesion was performed in 130 lesions in 101 patients during the study period. Their mean age was 52.5 ± 12 years and 42.5% were female. Pancreatic masses were the most common lesions (37.7% followed by lymph nodes (36.9%. Submucosal lesions (17.7% and liver lesions (7.7% accounted for rest of the cases. The overall diagnostic yield for EUS-FNAC (70% and CB (74.6% was not significantly different (P = 0.3 and their combined yield was 85.3%. For the 23 patients with submucosal lesion, diagnostic yield of CB (82.6% was significantly better than cytology (47.8%, P = 0.04. Conclusions: EUS-guided CB has better yield compared to cytology in gastrointestinal submucosal lesions. The combination of CB with cytology improves the overall yield of the procedure; and hence, they should be considered complimentary rather than alternatives.

  5. Value of contrast-enhanced ultrasound in rheumatoid arthritis

    International Nuclear Information System (INIS)

    Zordo, Tobias de; Mlekusch, Sabine P.; Feuchtner, Gudrun M.; Mur, Erich; Schirmer, Michael; Klauser, Andrea S.

    2007-01-01

    The purpose of this review is to describe the spectrum of sonographic findings in rheumatic diseases with respect to the diagnostic potential using US contrast media which prove activity or inactivity in synovial tissue where new treatment regimes target. Synovial activity can be found in non-erosive and erosive forms of primary and secondary osteoarthritis, and in inflammatory forms of joint diseases like rheumatoid arthritis and peripheral manifestations of spondyloarthritis including, ankylosing spondylitis, Reiter's syndrome, psoriatic arthritis and enteropathic arthritis. It can also be present in metabolic and endocrine forms of arthritis, in connective tissue arthropathies like systemic lupus erythematosus or scleroderma and in infectious arthritis. Ultrasound should be used as first-line imaging modality in suspected early cases of RA and other forms of arthritis, whereas contrast-enhanced ultrasound (CEUS) can further enable for sensitive assessment of vascularity which correlates with disease activity

  6. Value of contrast-enhanced ultrasound in rheumatoid arthritis

    Energy Technology Data Exchange (ETDEWEB)

    Zordo, Tobias de; Mlekusch, Sabine P.; Feuchtner, Gudrun M. [Department of Radiology II, Medical University Innsbruck, Anichstrasse 35, 6020 Innsbruck (Austria); Mur, Erich [Department of Internal Medicine, Medical University Innsbruck, Anichstrasse 35, 6020 Innsbruck (Austria); Schirmer, Michael [Department of Internal Medicine, Hospital of the Elisabethines Klagenfurt, Voelkermarkter Strasse 15-19, 9020 Klagenfurt (Austria); Klauser, Andrea S. [Department of Radiology II, Medical University Innsbruck, Anichstrasse 35, 6020 Innsbruck (Austria)], E-mail: andrea.klauser@i-med.ac.at

    2007-11-15

    The purpose of this review is to describe the spectrum of sonographic findings in rheumatic diseases with respect to the diagnostic potential using US contrast media which prove activity or inactivity in synovial tissue where new treatment regimes target. Synovial activity can be found in non-erosive and erosive forms of primary and secondary osteoarthritis, and in inflammatory forms of joint diseases like rheumatoid arthritis and peripheral manifestations of spondyloarthritis including, ankylosing spondylitis, Reiter's syndrome, psoriatic arthritis and enteropathic arthritis. It can also be present in metabolic and endocrine forms of arthritis, in connective tissue arthropathies like systemic lupus erythematosus or scleroderma and in infectious arthritis. Ultrasound should be used as first-line imaging modality in suspected early cases of RA and other forms of arthritis, whereas contrast-enhanced ultrasound (CEUS) can further enable for sensitive assessment of vascularity which correlates with disease activity.

  7. Endobronchial ultrasound elastography: a new method in endobronchial ultrasound-guided transbronchial needle aspiration.

    Science.gov (United States)

    Jiang, Jun-Hong; Turner, J Francis; Huang, Jian-An

    2015-12-01

    TBNA through the flexible bronchoscope is a 37-year-old technology that utilizes a TBNA needle to puncture the bronchial wall and obtain specimens of peribronchial and mediastinal lesions through the flexible bronchoscope for the diagnosis of benign and malignant diseases in the mediastinum and lung. Since 2002, the Olympus Company developed the first generation ultrasound equipment for use in the airway, initially utilizing an ultrasound probe introduced through the working channel followed by incoroporation of a fixed linear ultrasound array at the distal tip of the bronchoscope. This new bronchoscope equipped with a convex type ultrasound probe on the tip was subsequently introduced into clinical practice. The convex probe (CP)-EBUS allows real-time endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) of mediastinal and hilar lymph nodes. EBUS-TBNA is a minimally invasive procedure performed under local anesthesia that has been shown to have a high sensitivity and diagnostic yield for lymph node staging of lung cancer. In 10 years of EBUS development, the Olympus Company developed the second generation EBUS bronchoscope (BF-UC260FW) with the ultrasound image processor (EU-M1), and in 2013 introduced a new ultrasound image processor (EU-M2) into clinical practice. FUJI company has also developed a curvilinear array endobronchial ultrasound bronchoscope (EB-530 US) that makes it easier for the operator to master the operation of the ultrasonic bronchoscope. Also, the new thin convex probe endobronchial ultrasound bronchoscope (TCP-EBUS) is able to visualize one to three bifurcations distal to the current CP-EBUS. The emergence of EBUS-TBNA has also been accompanied by innovation in EBUS instruments. EBUS elastography is, then, a new technique for describing the compliance of structures during EBUS, which may be of use in the determination of metastasis to the mediastinal and hilar lymph nodes. This article describes these new EBUS

  8. High-resolution, low-delay, and error-resilient medical ultrasound video communication using H.264/AVC over mobile WiMAX networks.

    Science.gov (United States)

    Panayides, Andreas; Antoniou, Zinonas C; Mylonas, Yiannos; Pattichis, Marios S; Pitsillides, Andreas; Pattichis, Constantinos S

    2013-05-01

    In this study, we describe an effective video communication framework for the wireless transmission of H.264/AVC medical ultrasound video over mobile WiMAX networks. Medical ultrasound video is encoded using diagnostically-driven, error resilient encoding, where quantization levels are varied as a function of the diagnostic significance of each image region. We demonstrate how our proposed system allows for the transmission of high-resolution clinical video that is encoded at the clinical acquisition resolution and can then be decoded with low-delay. To validate performance, we perform OPNET simulations of mobile WiMAX Medium Access Control (MAC) and Physical (PHY) layers characteristics that include service prioritization classes, different modulation and coding schemes, fading channels conditions, and mobility. We encode the medical ultrasound videos at the 4CIF (704 × 576) resolution that can accommodate clinical acquisition that is typically performed at lower resolutions. Video quality assessment is based on both clinical (subjective) and objective evaluations.

  9. Assessment of substantia nigra echogenicity in German and Filipino populations using a portable ultrasound system.

    Science.gov (United States)

    Go, Criscely L; Frenzel, Antonia; Rosales, Raymond L; Lee, Lillian V; Benecke, Reiner; Dressler, Dirk; Walter, Uwe

    2012-02-01

    Transcranial sonography of the substantia nigra for diagnosing premotor stages of Parkinson disease has been attracting increasing interest. Standard reference values defining an abnormal increased echogenic size (hyperechogenicity) of the substantia nigra have been established in several populations using high-end stationary ultrasound systems. It is unknown whether a portable ultrasound system can be appropriately used and how the Filipino population would compare with the well-studied white population. We prospectively studied substantia nigra echogenic sizes and third ventricle widths in 71 healthy adult German participants and 30 age- and sex-matched Filipino participants using both a well-established stationary ultrasound system (in the German cohort) and a recently distributed portable ultrasound system (in both ethnic cohorts). Mean substantia nigra echogenic sizes, cutoff values defining abnormal hyperechogenicity, and intra-rater reliability were similar with both systems and in both ethnic cohorts studied. The Filipino and German participants did not differ with respect to the frequency of insufficient insonation conditions (each 3%) and substantia nigra hyperechogenicity (10% versus 9%; P = .80). However, third ventricle widths were smaller in the Filipino than the German participants (mean ± SD, 1.6 ± 1.1 versus 2.4 ± 1.0 mm; P = .004). The frequency of substantia nigra hyperechogenicity appears to be homogeneous in white and Asian populations. Screening for this feature may well be performed with a present-day portable ultrasound system.

  10. Microbubble embedded with upconversion nanoparticles as a bimodal contrast agent for fluorescence and ultrasound imaging

    International Nuclear Information System (INIS)

    Jin, Birui; Lin, Min; You, Minli; Xu, Feng; Lu, Tianjian; Zong, Yujin; Wan, Mingxi; Duan, Zhenfeng

    2015-01-01

    Bimodal imaging offers additional imaging signal thus finds wide spread application in clinical diagnostic imaging. Fluorescence/ultrasound bimodal imaging contrast agent using fluorescent dyes or quantum dots for fluorescence signal has emerged as a promising method, which however requires visible light or UV irradiation resulting in photobleaching, photoblinking, auto-fluorescence and limited tissue penetration depth. To surmount these problems, we developed a novel bimodal contrast agent using layer-by-layer assembly of upconversion nanoparticles onto the surface of microbubbles. The resulting microbubbles with average size of 2 μm provide enhanced ultrasound echo for ultrasound imaging and upconversion emission upon near infrared irradiation for fluorescence imaging. The developed bimodal contrast agent holds great potential to be applied in ultrasound target technique for targeted diseases diagnostics and therapy. (paper)

  11. Duplex ultrasound: A diagnostic tool for carotid stenosis management in type 2 diabetes mellitus

    Directory of Open Access Journals (Sweden)

    Yogan Kisten

    2013-07-01

    Full Text Available Background: Diabetic patients are at increased risk of developing cardiac events and stroke, and prevention of diabetes mellitus is therefore desirable. Marked geographical and ethnic variation in the prevalence of diabetes caused by urbanisation, demographic and epidemiological transitions has rendered this one of the major non-communicable diseases in South Africa. Duplex ultrasound (DUS plays an important role in primary health care in early detection of carotid atherosclerotic disease and the degree of carotid stenosis present. It is a reliable, cost-effective and non-invasive diagnostic tool. The purpose of this study was to determine the role of ultrasound in carotid stenosis management in type 2 diabetes mellitus (T2DM. Objectives: To determine the prevalence of carotid stenosis in a selected T2DM population using DUS and to correlate these findings with other predisposing atherosclerotic risk factors. Methods: The study setting was at an academic hospital in the Western Cape using carotid DUS reports of 103 diabetic subjects ≥ 35 years old. Predisposing risk factors were correlated with degree of carotid stenosis present. Data were analysed using the Fischer exact test, Chisquare and Student t-test. Results: Carotid DUS reports of 63 out of 103 T2DM patients revealed no evidence of a carotid stenosis, thereby lowering the risk profile. Forty patients were identified as having carotidstenosis; 22 symptomatic patients had a > 70% carotid stenosis which warranted surgicalintervention. A greater prevalence of stenosis in the Caucasian group, in both the male (p =0.0411 and female (p = 0.0458 cohorts, was noted. The overall trend suggested a relationship between T2DM and lifestyle, and a statistically significant relationship (p = 0.0063 between smoking and carotid stenosis was observed. Conclusion: T2DM and predisposing atherosclerotic risk factors significantly increased thepossibility of carotid stenosis development.

  12. On the safety of diagnostic ultrasound in pregnancy: Have we ...

    African Journals Online (AJOL)

    Robust evidence of the bioeffects of ultrasound is available from animal studies but human studies are less convincing. Nevertheless ... that exposure of pregnant mice to Doppler and .... New York: Informa Health Care; ... development of mice.

  13. Role of laparoscopy and ultrasound in the management of “impalpable testis” in children

    Directory of Open Access Journals (Sweden)

    Iskandar Rahardjo Budianto

    2014-10-01

    Conclusions: Laparoscopy is superior to ultrasound in the management of impalpable testes when high-resolution ultrasound is not available during the diagnostic process, with respect to both the sensitivity of localizing the testis and being more time and cost effective.

  14. Results of vardenafil mediated power Doppler ultrasound, contrast enhanced ultrasound and systematic random biopsies to detect prostate cancer.

    Science.gov (United States)

    Morelli, Girolamo; Pagni, Riccardo; Mariani, Chiara; Minervini, Riccardo; Morelli, Andrea; Gori, Francesco; Ferdeghini, Ezio Maria; Paterni, Marco; Mauro, Eva; Guidi, Elisa; Armillotta, Nicola; Canale, Domenico; Vitti, Paolo; Caramella, Davide; Minervini, Andrea

    2011-06-01

    We evaluated the ability of the phosphodiesterase-5 inhibitor vardenafil to increase prostate microcirculation during power Doppler ultrasound. We also evaluated the results of contrast and vardenafil enhanced targeted biopsies compared to those of standard 12-core random biopsies to detect cancer. Between May 2008 and January 2010, 150 consecutive patients with prostate specific antigen more than 4 ng/ml at first diagnosis with negative digital rectal examination and transrectal ultrasound, and no clinical history of prostatitis underwent contrast enhanced power Doppler ultrasound (bolus injection of 2.4 ml SonoVue® contrast agent), followed by vardenafil enhanced power Doppler ultrasound (1 hour after oral administration of vardenafil 20 mg). All patients underwent standard 12-core transrectal ultrasound guided random prostate biopsy plus 1 further sampling from each suspected hypervascular lesion detected by contrast and vardenafil enhanced power Doppler ultrasound. Prostate cancer was detected in 44 patients (29.3%). Contrast and vardenafil enhanced power Doppler ultrasound detected suspicious, contrast enhanced and vardenafil enhanced areas in 112 (74.6%) and 110 patients (73.3%), and was diagnostic for cancer in 32 (28.5%) and 42 (38%), respectively. Analysis of standard technique, and contrast and vardenafil enhanced power Doppler ultrasound findings by biopsy core showed significantly higher detection using vardenafil vs contrast enhanced power Doppler ultrasound and standard technique (41.2% vs 22.7% and 8.1%, p power Doppler ultrasound was 10% and 11.7% (p not significant). Vardenafil enhanced power Doppler ultrasound enables excellent visualization of the microvasculature associated with cancer and can improve the detection rate compared to contrast enhanced power Doppler ultrasound and the random technique. Copyright © 2011 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  15. Primary lymphoma of appendix: Ultrasound finding

    International Nuclear Information System (INIS)

    Sotillos Parra, V.E.; Belda Serrano, J.; Mota Castilla, A.; Falomir Gil, G.; Abreu Maqueda, V.; Trigueris Sanchez, M.; Hernandez Barcelo, J.E.; Martinez Diaz, F.

    1994-01-01

    We present an uncommon case of primary lymphoma of the appendix in a patient who complained of discomfort in lower right quadrant. The findings revealed by ultrasound, barium enema and CT scan are reported and the diagnostic aspects of this appendiceal tumor and others are discussed. (Author) 6 refs

  16. Surgical fiducial segmentation and tracking for pose estimation based on ultrasound B-mode images.

    Science.gov (United States)

    Lei Chen; Kuo, Nathanael; Aalamifar, Fereshteh; Narrow, David; Coon, Devin; Prince, Jerry; Boctor, Emad M

    2016-08-01

    Doppler ultrasound is a non-invasive diagnostic tool for the quantitative measurement of blood flow. However, given that it provides velocity data that is dependent on the location and angle of measurement, repeat measurements to detect problems over time may require an expert to return to the same location. We therefore developed an image-guidance system based on ultrasound B-mode images that enables an inexperienced user to position the ultrasound probe at the same site repeatedly in order to acquire a comparable time series of Doppler readings. The system utilizes a bioresorbable fiducial and complementing software composed of the fiducial detection, key points tracking, probe pose estimation, and graphical user interface (GUI) modules. The fiducial is an echogenic marker that is implanted at the surgical site and can be detected and tracked during ultrasound B-mode screening. The key points on the marker can next be used to determine the pose of the ultrasound probe with respect to the marker. The 3D representation of the probe with its position and orientation are then displayed in the GUI for the user guidance. The fiducial detection has been tested on the data sets collected from three animal studies. The pose estimation algorithm was validated by five data sets collected by a UR5 robot. We tested the system on a plastisol phantom and showed that it can detect and track the fiducial marker while displaying the probe pose in real-time.

  17. Musculoskeletal ultrasound and other imaging modalities in rheumatoid arthritis.

    Science.gov (United States)

    Ohrndorf, Sarah; Werner, Stephanie G; Finzel, Stephanie; Backhaus, Marina

    2013-05-01

    This review refers to the use of musculoskeletal ultrasound in patients with rheumatoid arthritis (RA) both in clinical practice and research. Furthermore, other novel sensitive imaging modalities (high resolution peripheral quantitative computed tomography and fluorescence optical imaging) are introduced in this article. Recently published ultrasound studies presented power Doppler activity by ultrasound highly predictive for later radiographic erosions in patients with RA. Another study presented synovitis detected by ultrasound being predictive of subsequent structural radiographic destruction irrespective of the ultrasound modality (grayscale ultrasound/power Doppler ultrasound). Further studies are currently under way which prove ultrasound findings as imaging biomarkers in the destructive process of RA. Other introduced novel imaging modalities are in the validation process to prove their impact and significance in inflammatory joint diseases. The introduced imaging modalities show different sensitivities and specificities as well as strength and weakness belonging to the assessment of inflammation, differentiation of the involved structures and radiological progression. The review tries to give an answer regarding how to best integrate them into daily clinical practice with the aim to improve the diagnostic algorithms, the daily patient care and, furthermore, the disease's outcome.

  18. Standardized ultrasound templates for diagnosing appendicitis reduce annual imaging costs.

    Science.gov (United States)

    Nordin, Andrew B; Sales, Stephen; Nielsen, Jason W; Adler, Brent; Bates, David Gregory; Kenney, Brian

    2018-01-01

    Ultrasound is preferred over computed tomography (CT) for diagnosing appendicitis in children to avoid undue radiation exposure. We previously reported our experience in instituting a standardized appendicitis ultrasound template, which decreased CT rates by 67.3%. In this analysis, we demonstrate the ongoing cost savings associated with using this template. Retrospective chart review for the time period preceding template implementation (June 2012-September 2012) was combined with prospective review through December 2015 for all patients in the emergency department receiving diagnostic imaging for appendicitis. The type of imaging was recorded, and imaging rates and ultrasound test statistics were calculated. Estimated annual imaging costs based on pretemplate ultrasound and CT utilization rates were compared with post-template annual costs to calculate annual and cumulative savings. In the pretemplate period, ultrasound and CT rates were 80.2% and 44.3%, respectively, resulting in a combined annual cost of $300,527.70. Similar calculations were performed for each succeeding year, accounting for changes in patient volume. Using pretemplate rates, our projected 2015 imaging cost was $371,402.86; however, our ultrasound rate had increased to 98.3%, whereas the CT rate declined to 9.6%, yielding an annual estimated cost of $224,853.00 and a savings of $146,549.86. Since implementation, annual savings have steadily increased for a cumulative cost savings of $336,683.83. Standardizing ultrasound reports for appendicitis not only reduces the use of CT scans and the associated radiation exposure but also decreases annual imaging costs despite increased numbers of imaging studies. Continued cost reduction may be possible by using diagnostic algorithms. Copyright © 2017 Elsevier Inc. All rights reserved.

  19. Expert system for fast reactor diagnostic

    International Nuclear Information System (INIS)

    Parcy, J.P.

    1982-09-01

    A general description of expert systems is given. The operation of a fast reactor is reviewed. The expert system to the diagnosis of breakdowns limited to the reactor core. The structure of the system is described: specification of the diagnostics; structure of the data bank and evaluation of the rules; specification of the prediagnostics and evaluation; explanation of the diagnostics; time evolution of the system; comparison with other expert systems. Applications to some cases of faults are finally presented [fr

  20. Value of mammography and breast ultrasound in male patients with nipple discharge.

    Science.gov (United States)

    Muñoz Carrasco, Rafaela; Álvarez Benito, Marina; Rivin del Campo, Eleonor

    2013-03-01

    To assess the contribution of mammography and ultrasound in men with nipple discharge. All men with nipple discharge who underwent mammography and/or ultrasound between 1993 and 2011 in our hospital were retrospectively evaluated. Radiological findings were classified according to BI-RADS lexicon. The final diagnosis was made based on histopathological results or clinical-radiological follow-up. The diagnostic performance of physical examination, mammography and ultrasound was calculated and compared. 26 men with 21 mammograms and 19 ultrasounds were reviewed. The final diagnoses were: 6 carcinomas (23.1%), 10 gynaecomastias, 2 pseudogynaecomastias and 8 normal breast tissues. Mammograms and ultrasounds performed on all five patients with infiltrating carcinoma showed a mass (categories 4 and 5). In all these patients except one, a breast mass was also noted and the physical examination was positive or suspected malignancy. In the patient with carcinoma in situ, the only conspicuous clinical sign was bloody nipple discharge and the mammography showed calcifications (category 4) that were not visible on ultrasound. Radiological findings of all patients without malignancy were classified as categories 1 and 2. The diagnostic performance of physical examination was lower than mammography and ultrasound (P>0.05). Mammography was more sensitive than ultrasound (100% vs. 83.3%). Both techniques showed the same specificity (100%). Men with nipple discharge have a high incidence of breast carcinoma. Nipple discharge may be the only clinical sign of carcinoma in situ. Mammography and ultrasound are useful in the evaluation of men with nipple discharge, diagnosing carcinoma in initial stages, avoiding unnecessary biopsies. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  1. Prostatic carcinoma. Diagnostic and stating: MR imaging. Cancer de la prostate Diagnostic et bilan: role de l'imagerie

    Energy Technology Data Exchange (ETDEWEB)

    Roy, C; Spittler, G; Jacqmin, D [Centre Hospitalier Universitaire, 67 - Strasbourg (FR); Morel, M [Clinique Saint-Francois, 67 Haguenau (FR)

    1991-01-01

    Prostatic carcinoma is the second most commun cause of cancer death over 60 years. It is suspected by digital examination and prostatic specific antigen dosage. Transrectal ultrasound shows the tumor as an hypoechoic lesion. Sensitivity is good but specificity is low. Transrectal biopsy of prostate guided by transrectal ultrasound made the diagnosis. At present, MR Imaging is the most accurate diagnostic modality for loco-regional staging of prostatic carcinoma.

  2. Impact of point-of-care ultrasound on quality of care in clinical practice

    Directory of Open Access Journals (Sweden)

    Adhikari S

    2014-09-01

    Full Text Available Srikar Adhikari,1 Richard Amini,1 Lori A Stolz,1 Michael Blaivas2 1Department of Emergency Medicine, University of Arizona Medical Center, Tucson, AZ, 2Department of Internal Medicine, University of South Carolina School of Medicine, Columbia, SC, USA Abstract: The use of point-of-care (POC ultrasonography has rapidly expanded in recent years, in both academic and community settings. It is one of the few diagnostic modalities that can be performed rapidly at the bedside by a physician and has significant impact on patient outcomes. It is portable, readily accessible, and cost-effective, and has no risk of ionizing radiation. There is an abundance of evidence that supports the use of POC ultrasound by physicians in different subspecialties. Multiple studies have documented the diagnostic accuracy of POC ultrasound and its ability to decrease the time to definitive treatment. As ultrasound technology has advanced, POC ultrasound applications have also evolved from being used solely in patients with blunt abdominal trauma to applications for nearly every clinical scenario imaginable. From performing procedures more safely to diagnosing pathology more quickly, POC ultrasound is radically changing clinical practice, patient outcomes, and the overall quality of patient care a clinician can provide. Recently, there has been a paradigm shift involving a symptom-based approach to POC ultrasound. This unique symptom-based ultrasound approach has led to improved quality of care in a variety of clinical settings. Keywords: point-of-care ultrasound, ultrasonography, bedside ultrasound, emergency physician, emergency department, quality, symptom-based

  3. Ultrasound in evaluating ovarian reserve

    Directory of Open Access Journals (Sweden)

    Eman Ahmaed Shawky Sabek

    2015-12-01

    Full Text Available The objective of this study was to compare the diagnostic accuracy of transvaginal ultrasound (TVS, as a less invasive technique instead of hormonal assay to evaluate the ovarian reserve. This study included fifty-five females with breast cancer and we compared the ovarian reserve for these patients by hormonal assay through measuring the serum AntiMullerian Hormone (AMH level and follicular stimulating hormone (FSH level before and after chemotherapy, and by transvaginal ultrasound through the ovarian volume (OV calculation and counting the Antral follicles (AFC before and after chemotherapy treatment. There was decline in the AntiMullerian Hormone level after chemotherapy by 27 ± 11.19% and decrease in the Antral follicle counts by 21 ± 13.43%. In conclusion there was strong relation between AMH level and AFC which makes the use of transvaginal ultrasound is a reliable alternative method to the hormonal assay to detect the ovarian reserve.

  4. Phase-Change Nanoparticles Using Highly Volatile Perfluorocarbons: Toward a Platform for Extravascular Ultrasound Imaging

    Directory of Open Access Journals (Sweden)

    Terry O. Matsunaga, Paul S. Sheeran, Samantha Luois, Jason E. Streeter, Lee B. Mullin, Bhaskar Banerjee, Paul A. Dayton

    2012-01-01

    Full Text Available Recent efforts using perfluorocarbon (PFC nanoparticles in conjunction with acoustic droplet vaporization has introduced the possibility of expanding the diagnostic and therapeutic capability of ultrasound contrast agents to beyond the vascular space. Our laboratories have developed phase-change nanoparticles (PCNs from the highly volatile PFCs decafluorobutane (DFB, bp =-2 °C and octafluoropropane (OFP, bp =-37 °C for acoustic droplet vaporization. Studies with commonly used clinical ultrasound scanners have demonstrated the ability to vaporize PCN emulsions with frequencies and mechanical indices that may significantly decrease tissue bioeffects. In addition, these contrast agents can be formulated to be stable at physiological temperatures and the perfluorocarbons can be mixed to modulate the balance between sensitivity to ultrasound and general stability. We herein discuss our recent efforts to develop finely-tuned diagnostic/molecular imaging agents for tissue interrogation. We discuss studies currently under investigation as well as potential diagnostic and therapeutic paradigms that may emerge as a result of formulating PCNs with low boiling point PFCs.

  5. Compensated Row-Column Ultrasound Imaging System Using Multilayered Edge Guided Stochastically Fully Connected Random Fields.

    Science.gov (United States)

    Ben Daya, Ibrahim; Chen, Albert I H; Shafiee, Mohammad Javad; Wong, Alexander; Yeow, John T W

    2017-09-06

    The row-column method received a lot of attention for 3-D ultrasound imaging. By reducing the number of connections required to address the 2-D array and therefore reducing the amount of data to handle, this addressing method allows for real time 3-D imaging. Row-column still has its limitations: the issues of sparsity, speckle noise inherent to ultrasound, the spatially varying point spread function, and the ghosting artifacts inherent to the row-column method must all be taken into account when building a reconstruction framework. In this research, we build on a previously published system and propose an edge-guided, compensated row-column ultrasound imaging system that incorporates multilayered edge-guided stochastically fully connected conditional random fields to address the limitations of the row-column method. Tests carried out on simulated and real row-column ultrasound images show the effectiveness of our proposed system over other published systems. Visual assessment show our proposed system's potential at preserving edges and reducing speckle. Quantitative analysis shows that our proposed system outperforms previously published systems when evaluated with metrics such as Peak Signal-to-Noise Ratio, Coefficient of Correlation, and Effective Number of Looks. These results show the potential of our proposed system as an effective tool for enhancing 3-D row-column imaging.

  6. A comparison of liver surface and hepatic vein wall ultrasound as markers for fibrosis or cirrhosis of the liver

    International Nuclear Information System (INIS)

    Allan, Richard B.; Thoirs, Kerry A.

    2014-01-01

    Objective: Clinical management of patients with suspected chronic liver disease (CLD) relies on liver biopsy which carries significant risks. This study aimed to compare the diagnostic accuracy of two previously described ultrasound techniques of liver assessment in patients who were clinically at risk of cirrhosis or fibrosis. Methods: We obtained approval from our institutional review board prior to commencement of this prospective, blinded, observational study. A sample of convenience (n = 65) was recruited from the Flinders Medical Centre endoscopy unit to compare the liver biopsy results and ultrasound assessments of the liver surface and the hepatic vein wall. The diagnostic accuracy of each ultrasound technique was measured by calculating the sensitivity, specificity, positive and negative likelihood ratios, positive and negative predictive values and diagnostic accuracy. Comparisons between diagnostic performance of the two techniques was calculated with McNemar's χ 2 test. Results: Highest diagnostic accuracy (0.721) was demonstrated for assessment of the left lobe liver surface. Highest specificity was demonstrated for assessments of the left lobe liver (0.94) and right liver surfaces (0.98) and sensitivity was low for all ultrasound assessments (0–0.5). Conclusion: Compared to the hepatic vein wall image, the left surface image has higher specificity and diagnostic accuracy, a higher technical success rate, and has higher inter-reader agreement. The high specificity and low false positive rate for ultrasound assessment of liver surface indicates that a patient testing negative can potentially be ruled out of having CLD without the need for liver biopsy

  7. Ultrasound of the coracoclavicular ligaments in the acute phase of an acromioclavicular disjunction: Comparison of radiographic, ultrasound and MRI findings

    Energy Technology Data Exchange (ETDEWEB)

    Faruch Bilfeld, Marie; Lapegue, Franck; Chiavassa Gandois, Helene; Bayol, Marie Aurelie; Sans, Nicolas [CHU Toulouse-Purpan, Service de Radiologie, Toulouse Cedex 9 (France); Bonnevialle, Nicolas [CHU Toulouse-Purpan, Service d' Orthopedie, Toulouse Cedex 9 (France)

    2017-02-15

    Acromioclavicular joint injuries are typically diagnosed by clinical and radiographic assessment with the Rockwood classification, which is crucial for treatment planning. The purpose of this study was to describe how the ultrasound findings of acromioclavicular joint injury compare with radiography and MRI findings. Forty-seven patients with suspected unilateral acromioclavicular joint injury after acute trauma were enrolled in this prospective study. All patients underwent digital radiography, ultrasound and 3T MRI. A modified Rockwood classification was used to evaluate the coracoclavicular ligaments. The classifications of acromioclavicular joint injuries diagnosed with radiography, ultrasound and MRI were compared. MRI was used as the gold standard. The agreement between the ultrasound and MRI findings was very good, with a correlation coefficient of 0.83 (95 % CI: 0.72-0.90; p < 0.0001). Ultrasound detected coracoclavicular ligament injuries with a sensitivity of 88.9 %, specificity of 90.0 %, positive predictive value of 92.3 % and negative predictive value of 85.7 %. The agreement between the ultrasound and radiography findings was poor, with a correlation coefficient of 0.69 (95 % CI: 0.51-0.82; p < 0.0001). Ultrasound is an effective examination for the diagnostic work-up of lesions of the coracoclavicular ligaments in the acute phase of an acromioclavicular injury. (orig.)

  8. Ultrasound of the coracoclavicular ligaments in the acute phase of an acromioclavicular disjunction: Comparison of radiographic, ultrasound and MRI findings

    International Nuclear Information System (INIS)

    Faruch Bilfeld, Marie; Lapegue, Franck; Chiavassa Gandois, Helene; Bayol, Marie Aurelie; Sans, Nicolas; Bonnevialle, Nicolas

    2017-01-01

    Acromioclavicular joint injuries are typically diagnosed by clinical and radiographic assessment with the Rockwood classification, which is crucial for treatment planning. The purpose of this study was to describe how the ultrasound findings of acromioclavicular joint injury compare with radiography and MRI findings. Forty-seven patients with suspected unilateral acromioclavicular joint injury after acute trauma were enrolled in this prospective study. All patients underwent digital radiography, ultrasound and 3T MRI. A modified Rockwood classification was used to evaluate the coracoclavicular ligaments. The classifications of acromioclavicular joint injuries diagnosed with radiography, ultrasound and MRI were compared. MRI was used as the gold standard. The agreement between the ultrasound and MRI findings was very good, with a correlation coefficient of 0.83 (95 % CI: 0.72-0.90; p < 0.0001). Ultrasound detected coracoclavicular ligament injuries with a sensitivity of 88.9 %, specificity of 90.0 %, positive predictive value of 92.3 % and negative predictive value of 85.7 %. The agreement between the ultrasound and radiography findings was poor, with a correlation coefficient of 0.69 (95 % CI: 0.51-0.82; p < 0.0001). Ultrasound is an effective examination for the diagnostic work-up of lesions of the coracoclavicular ligaments in the acute phase of an acromioclavicular injury. (orig.)

  9. Role of ultrasound in rotator cuff tears

    International Nuclear Information System (INIS)

    Siddiqi, H.A.; Mirza, T.

    2010-01-01

    The study was designed to evaluate the efficacy of ultrasound in rotator cuff tears and to compare it with MRI. Total number of patients was thirty. All of these were above thirty years of age and were referred by clinicians, with shoulder pain for diagnostic workup. Post operative patients were excluded. Ultrasound and Magnetic Resonance Imaging (MRI) were performed on each patient. Same operator performed ultrasound in all patients. Ultrasound (US) and Magnetic Resonance Imaging (MRI) detected equal number of full thickness tears while two partial thickness tears were missed on US. Hypoechoic defect was the most important primary sign while cortical irregularity and fluid in subacromial and subdeltroid busra were the most important secondary signs on US. US was equally effective to MRI in detection of rotator cuff tears. It should be the primary investigation because of its availability, cost effective and real time evaluation provided significant expertise is developed, as it is highly operator dependent. (author)

  10. A multipoint feedback control system for scanned focussed ultrasound hyperthermia

    International Nuclear Information System (INIS)

    Johnson, C.; Kress, R.; Roemer, R.; Hynynen, K.

    1987-01-01

    A multipoint feedback control system has been developed and tested for use with a scanned focussed ultrasound hyperthermia system. Extensive in-vivo tests (using a perfused organ model) have been made to evaluate the basic performance characteristics of the feedback control scheme for control of temperature in perfused media. The results of these tests are presented and compared with the predictions of a simulation routine. The control scheme was also tested in vivo using dogs' thighs and kidneys. Thigh experiments show the control scheme responds well to the affects of vasodilation and is able to maintain the targeted temperatures. In kidney experiments, where the rate of perfusion was controllable, the power adjusting algorithm successfully maintained uniform temperature distributions across regions of varying rates of perfusion. As a conclusion, the results show that this multipoint feedback controller scheme induces uniform temperature distributions when used with scanned focussed ultrasound systems

  11. Remotely supported prehospital ultrasound: A feasibility study of real-time image transmission and expert guidance to aid diagnosis in remote and rural communities.

    Science.gov (United States)

    Eadie, Leila; Mulhern, John; Regan, Luke; Mort, Alasdair; Shannon, Helen; Macaden, Ashish; Wilson, Philip

    2017-01-01

    Introduction Our aim is to expedite prehospital assessment of remote and rural patients using remotely-supported ultrasound and satellite/cellular communications. In this paradigm, paramedics are remotely-supported ultrasound operators, guided by hospital-based specialists, to record images before receiving diagnostic advice. Technology can support users in areas with little access to medical imaging and suboptimal communications coverage by connecting to multiple cellular networks and/or satellites to stream live ultrasound and audio-video. Methods An ambulance-based demonstrator system captured standard trauma and novel transcranial ultrasound scans from 10 healthy volunteers at 16 locations across the Scottish Highlands. Volunteers underwent brief scanning training before receiving expert guidance via the communications link. Ultrasound images were streamed with an audio/video feed to reviewers for interpretation. Two sessions were transmitted via satellite and 21 used cellular networks. Reviewers rated image and communication quality, and their utility for diagnosis. Transmission latency and bandwidth were recorded, and effects of scanner and reviewer experience were assessed. Results Appropriate views were provided in 94% of the simulated trauma scans. The mean upload rate was 835/150 kbps and mean latency was 114/2072 ms for cellular and satellite networks, respectively. Scanning experience had a significant impact on time to achieve a diagnostic image, and review of offline scans required significantly less time than live-streamed scans. Discussion This prehospital ultrasound system could facilitate early diagnosis and streamlining of treatment pathways for remote emergency patients, being particularly applicable in rural areas worldwide with poor communications infrastructure and extensive transport times.

  12. Super-Resolution Image Reconstruction Applied to Medical Ultrasound

    Science.gov (United States)

    Ellis, Michael

    Ultrasound is the preferred imaging modality for many diagnostic applications due to its real-time image reconstruction and low cost. Nonetheless, conventional ultrasound is not used in many applications because of limited spatial resolution and soft tissue contrast. Most commercial ultrasound systems reconstruct images using a simple delay-and-sum architecture on receive, which is fast and robust but does not utilize all information available in the raw data. Recently, more sophisticated image reconstruction methods have been developed that make use of far more information in the raw data to improve resolution and contrast. One such method is the Time-Domain Optimized Near-Field Estimator (TONE), which employs a maximum a priori estimation to solve a highly underdetermined problem, given a well-defined system model. TONE has been shown to significantly improve both the contrast and resolution of ultrasound images when compared to conventional methods. However, TONE's lack of robustness to variations from the system model and extremely high computational cost hinder it from being readily adopted in clinical scanners. This dissertation aims to reduce the impact of TONE's shortcomings, transforming it from an academic construct to a clinically viable image reconstruction algorithm. By altering the system model from a collection of individual hypothetical scatterers to a collection of weighted, diffuse regions, dTONE is able to achieve much greater robustness to modeling errors. A method for efficient parallelization of dTONE is presented that reduces reconstruction time by more than an order of magnitude with little loss in image fidelity. An alternative reconstruction algorithm, called qTONE, is also developed and is able to reduce reconstruction times by another two orders of magnitude while simultaneously improving image contrast. Each of these methods for improving TONE are presented, their limitations are explored, and all are used in concert to reconstruct in

  13. Unpowered wireless transmission of ultrasound signals

    International Nuclear Information System (INIS)

    Huang, H; Paramo, D; Deshmukh, S

    2011-01-01

    This paper presents a wireless ultrasound sensing system that uses frequency conversion to convert the ultrasound signal to a microwave signal and transmit it directly without digitization. Constructed from a few passive microwave components, the sensor is able to sense, modulate, and transmit the full waveform of ultrasound signals wirelessly without requiring any local power source. The principle of operation of the unpowered wireless ultrasound sensor is described first, and this is followed by a detailed description of the implementation of the sensor and the sensor interrogation unit using commercially available antennas and microwave components. Validation of the sensing system using an ultrasound pitch–catch system and the power analysis model of the system are also presented

  14. Size and Ultrasound Features Affecting Results of Ultrasound-Guided Fine-Needle Aspiration of Thyroid Nodules.

    Science.gov (United States)

    Dong, YiJie; Mao, MinJing; Zhan, WeiWei; Zhou, JianQiao; Zhou, Wei; Yao, JieJie; Hu, YunYun; Wang, Yan; Ye, TingJun

    2017-11-09

    Our goal was to assess the diagnostic efficacy of ultrasound (US)-guided fine-needle aspiration (FNA) of thyroid nodules according to size and US features. A retrospective correlation was made with 1745 whole thyroidectomy and hemithyroidectomy specimens with preoperative US-guided FNA results. All cases were divided into 5 groups according to nodule size (≤5, 5.1-10, 10.1-15, 15.1-20, and >20 mm). For target nodules, static images and cine clips of conventional US and color Doppler were obtained. Ultrasound images were reviewed and evaluated by two radiologists with at least 5 years US working experience without knowing the results of pathology, and then agreement was achieved. The Bethesda category I rate was higher in nodules larger than 15 mm (P 20 mm) with several US features tended to yield false-negative FNA results. © 2017 by the American Institute of Ultrasound in Medicine.

  15. Essential ultrasound techniques of the pediatric airway

    DEFF Research Database (Denmark)

    Stafrace, Samuel; Engelhardt, Thomas; Teoh, Wendy H

    2016-01-01

    Ultrasound of the airways is a technique which has been described in a number of recent articles and reviews highlighting the diagnostic possibilities and simple methodology. However, there is a paucity of information focusing specifically on such methods in children where equipment, technique, a...

  16. Intelligent neural network diagnostic system

    International Nuclear Information System (INIS)

    Mohamed, A.H.

    2010-01-01

    Recently, artificial neural network (ANN) has made a significant mark in the domain of diagnostic applications. Neural networks are used to implement complex non-linear mappings (functions) using simple elementary units interrelated through connections with adaptive weights. The performance of the ANN is mainly depending on their topology structure and weights. Some systems have been developed using genetic algorithm (GA) to optimize the topology of the ANN. But, they suffer from some limitations. They are : (1) The computation time requires for training the ANN several time reaching for the average weight required, (2) Slowness of GA for optimization process and (3) Fitness noise appeared in the optimization of ANN. This research suggests new issues to overcome these limitations for finding optimal neural network architectures to learn particular problems. This proposed methodology is used to develop a diagnostic neural network system. It has been applied for a 600 MW turbo-generator as a case of real complex systems. The proposed system has proved its significant performance compared to two common methods used in the diagnostic applications.

  17. Point-of-Care Ultrasound: A Trend in Health Care.

    Science.gov (United States)

    Buerger, Anita M; Clark, Kevin R

    2017-11-01

    To discuss the current and growing use of point-of-care (POC) ultrasound in the management and care of patients. Several electronic research databases were searched to find articles that emphasized the use of POC ultrasound by health care providers who manage and treat critically ill or injured patients. Thirty-five relevant peer-reviewed journal articles were selected for this literature review. Common themes identified in the literature included the use of POC ultrasound in emergency medicine, military medicine, and remote care; comparison of POC ultrasound to other medical imaging modalities; investigation of the education and training required for nonimaging health care professionals who perform POC ultrasound in their practices; and discussion of the financial implications and limitations of POC ultrasound. POC ultrasound provides clinicians with real-time information to better manage and treat critically ill or injured patients in emergency medicine, military medicine, and remote care. In addition to providing immediate bedside diagnostic information, use of POC ultrasound has increased because of concerns regarding radiation protection. Finally, the expansion of POC ultrasound to other specialty areas requires nonimaging health care professionals to perform bedside ultrasound examinations and interpret the resulting images. Because POC ultrasound is user-dependent, adequate training is essential for all who perform and interpret the examinations. Research involving POC ultrasound will continue as innovations and confidence in ultrasound applications advance. Future research should continue to examine the broad use of POC ultrasound in patient care and management. ©2017 American Society of Radiologic Technologists.

  18. Dissimilar trend of nonlinearity in ultrasound transducers and systems at resonance and non-resonance frequencies

    DEFF Research Database (Denmark)

    Ghasemi, Negareh; Zare, Firuz; Davari, Pooya

    2017-01-01

    Several factors can affect performance of an ultrasound system such as quality of excitation signal and ultrasound transducer behaviour. Nonlinearity of piezoelectric ultrasound transducers is a key determinant in designing a proper driving power supply. Although, the nonlinearity of piezoelectric...... was excited at different frequencies. Different excitation signals were generated using a linear power amplifier and a multilevel converter within a range of 30–200 V. Empirical relation was developed to express the resistance of the piezoelectric transducer as a nonlinear function of both excitation voltage...... and resonance frequency. The impedance measurements revealed that at higher voltage ranges, the piezoelectric transducer can be easily saturated. Also, it was shown that for the developed ultrasound system composed of two transducers (one transmitter and one receiver), the output voltage measured across...

  19. Advanced ultrasound applications in the assessment of renal transplants: contrast-enhanced ultrasound, elastography, and B-flow.

    Science.gov (United States)

    Morgan, Tara A; Jha, Priyanka; Poder, Liina; Weinstein, Stefanie

    2018-04-09

    Ultrasound is routinely used as the first imaging exam for evaluation of renal transplants and can identify most major surgical complications and evaluate vascularity with color Doppler. Ultrasound is limited, however, in the detection of parenchymal disease processes and Doppler evaluation is also prone to technical errors. Multiple new ultrasound applications have been developed and are under ongoing investigation which could add additional diagnostic capability to the routine ultrasound exam with minimal additional time, cost, and patient risk. Contrast-enhanced ultrasound (CEUS) can be used off-label in the transplant kidney, and can assist in detection of infection, trauma, and vascular complications. CEUS also can demonstrate perfusion of the transplant assessed quantitatively with generation of time-intensity curves. Future directions of CEUS include monitoring treatment response and microbubble targeted medication delivery. Elastography is an ultrasound application that can detect changes in tissue elasticity, which is useful to diagnose diffuse parenchymal disease, such as fibrosis, otherwise unrecognizable with ultrasound. Elastography has been successfully applied in other organs including the liver, thyroid, and breast; however, it is still under development for use in the transplant kidney. Unique properties of the transplant kidney including its heterogeneity, anatomic location, and other technical factors present challenges in the development of reference standard measurements. Lastly, B-flow imaging is a flow application derived from B-mode. This application can show the true lumen size of a vessel which is useful to depict vascular anatomy and bypasses some of the pitfalls of color Doppler such as demonstration of slow flow.

  20. Dynamic MRI-based computer aided diagnostic systems for early detection of kidney transplant rejection: A survey

    Science.gov (United States)

    Mostapha, Mahmoud; Khalifa, Fahmi; Alansary, Amir; Soliman, Ahmed; Gimel'farb, Georgy; El-Baz, Ayman

    2013-10-01

    Early detection of renal transplant rejection is important to implement appropriate medical and immune therapy in patients with transplanted kidneys. In literature, a large number of computer-aided diagnostic (CAD) systems using different image modalities, such as ultrasound (US), magnetic resonance imaging (MRI), computed tomography (CT), and radionuclide imaging, have been proposed for early detection of kidney diseases. A typical CAD system for kidney diagnosis consists of a set of processing steps including: motion correction, segmentation of the kidney and/or its internal structures (e.g., cortex, medulla), construction of agent kinetic curves, functional parameter estimation, diagnosis, and assessment of the kidney status. In this paper, we survey the current state-of-the-art CAD systems that have been developed for kidney disease diagnosis using dynamic MRI. In addition, the paper addresses several challenges that researchers face in developing efficient, fast and reliable CAD systems for the early detection of kidney diseases.

  1. Ultrasound versus Magnetic Resonance Arthrography in Acetabular Labral Tear Diagnostics: A Prospective Comparison in 20 Dysplastic Hips

    Energy Technology Data Exchange (ETDEWEB)

    Troelsen, A.; Jacobsen, S.; Bolvig, L.; Gelineck, J.; Roemer, L.; Soeballe, K. [Orthopedic Research Unit and Dept. of Radiology, Univ. Hospital of Aarhus, A arhus (Denmark)

    2007-11-15

    Background: Acetabular labral tears are highly associated with hip dysplasia. Magnetic resonance arthrography (MR arthrography) is the expensive and time-consuming contemporary gold-standard method in the radiological assessment of acetabular labral tears. Purpose: To assess the diagnostic ability of noninvasive ultrasound (US) examination compared to MR arthrography in diagnosing acetabular labral tears in dysplastic hip joints. Material and Methods: The study compared US examination and MR arthrography diagnosis of labral tears in 20 consecutively referred dysplastic hip joints. Results: The ability to diagnose acetabular labral tears upon US examination was calculated: sensitivity 44%, specificity 75%, positive predictive value 88%, and negative predictive value 25%. Conclusion: The ability of US examination in diagnosing acetabular labral tears is not yet good enough. The technique is still to be developed, and more experience, especially with the interpretation of US examinations, is needed.

  2. Nuclear power plant diagnostic system

    International Nuclear Information System (INIS)

    Prokop, K.; Volavy, J.

    1982-01-01

    Basic information is presented on diagnostic systems used at nuclear power plants with PWR reactors. They include systems used at the Novovoronezh nuclear power plant in the USSR, at the Nord power plant in the GDR, the system developed at the Hungarian VEIKI institute, the system used at the V-1 nuclear power plant at Jaslovske Bohunice in Czechoslovakia and systems of the Rockwell International company used in US nuclear power plants. These diagnostic systems are basically founded on monitoring vibrations and noise, loose parts, pressure pulsations, neutron noise, coolant leaks and acoustic emissions. The Rockwell International system represents a complex unit whose advantage is the on-line evaluation of signals which gives certain instructions for the given situation directly to the operator. The other described systems process signals using similar methods. Digitized signals only serve off-line computer analyses. (Z.M.)

  3. A new computer aided diagnosis system for evaluation of chronic liver disease with ultrasound shear wave elastography imaging.

    Science.gov (United States)

    Gatos, Ilias; Tsantis, Stavros; Spiliopoulos, Stavros; Karnabatidis, Dimitris; Theotokas, Ioannis; Zoumpoulis, Pavlos; Loupas, Thanasis; Hazle, John D; Kagadis, George C

    2016-03-01

    Classify chronic liver disease (CLD) from ultrasound shear-wave elastography (SWE) imaging by means of a computer aided diagnosis (CAD) system. The proposed algorithm employs an inverse mapping technique (red-green-blue to stiffness) to quantify 85 SWE images (54 healthy and 31 with CLD). Texture analysis is then applied involving the automatic calculation of 330 first and second order textural features from every transformed stiffness value map to determine functional features that characterize liver elasticity and describe liver condition for all available stages. Consequently, a stepwise regression analysis feature selection procedure is utilized toward a reduced feature subset that is fed into the support vector machines (SVMs) classification algorithm in the design of the CAD system. With regard to the mapping procedure accuracy, the stiffness map values had an average difference of 0.01 ± 0.001 kPa compared to the quantification results derived from the color-box provided by the built-in software of the ultrasound system. Highest classification accuracy from the SVM model was 87.0% with sensitivity and specificity values of 83.3% and 89.1%, respectively. Receiver operating characteristic curves analysis gave an area under the curve value of 0.85 with [0.77-0.89] confidence interval. The proposed CAD system employing color to stiffness mapping and classification algorithms offered superior results, comparing the already published clinical studies. It could prove to be of value to physicians improving the diagnostic accuracy of CLD and can be employed as a second opinion tool for avoiding unnecessary invasive procedures.

  4. The Effects of Ultrasound on Biological Systems: Site

    Science.gov (United States)

    El-Karmi, Anan M.

    Earlier studies (Dinno et al., Ultrasound Med. Biol. 15:461 -470; 1989) demonstrated that ultrasound at therapeutic intensities causes large increases in total conductance (G_{rm t}) of frog skin. These changes were attributed to non-thermal mechanisms, primarily, cavitation. In this study, the site(s) and mechanism(s) of action of ultrasound for the increase in G_{rm t} were examined. The reversible changes in G_{rm t } and sodium current were monitored in real time as a function of ultrasound exposure. Amiloride, a sodium channel blocker, was used to differentiate between cellular (G_{rm c}) and paracellular (G_{rm s}) pathways in the presence and absence of ultrasound. No significant changes were detected in G_ {rm c}. However, changes in G _{rm s} were significant. These results demonstrate that most of the increase in G _{rm t} due to ultrasound is taking place in the paracellular pathways. Sodium channels were not significantly affected by ultrasound. Thus, the changes in G_{rm c} are not specific. The effects of ultrasound were examined in the presence of radical scavengers and antioxidants. The increase in G_{rm t} due to ultrasound was significantly minimized in the presence of cystamine, cysteamine, and sodium ascorbate. This demonstrates that free radicals and other reactive species generated by cavitation are causing the increase in G_ {rm t}, possibly by acting from inside the cells. Radical scavengers and antioxidants are providing protection from oxidative damage but are not involved in the recovery of G_{ rm t} towards steady state values after sonication. The role of Ca^{2+} in the effects of ultrasound was examined since many of the cellular reactions involved in tissue recovery are dependent on the intracellular availability of free Ca^{2+}. The percentage increase in G_{rm t} in the presence of Ca^{2+} was larger than in its absence (140% vs. 27%). The time constant for G_{rm t} to return to steady state was longer in calcium-free solutions (122

  5. A review of the recommendations governing quality assurance of ultrasound systems used for guidance in prostate brachytherapy.

    Science.gov (United States)

    Doyle, Andrea Jane; King, Deirdre M; Browne, Jacinta E

    2017-12-01

    Ultrasound guided brachytherapy for the treatment of prostate cancer has become a routine treatment option, due to many benefits including patient recovery and dose localisation [1]; however it is not clear whether the standards which govern the image quality for these systems are adequate. Upon review of the recommended standards for ultrasound systems used in prostate brachytherapy procedures, the recommended tests do not appear to be specific to the clinical application of ultrasound guided prostate brachytherapy. Rather they are generic and similar to those recommended for other clinical applications such as general abdominal scanning [2]. Furthermore, there is growing evidence that these tests should be specific to the clinical application [3,4] in order to gain meaningful data about the performance of the system for the application, and also to detect clinically relevant changes in quality control results. An additional problem is that there are no clinically relevant test phantom recommended for the quality assurance of ultrasound systems used in prostate brachytherapy. The image quality for this application of ultrasound needs to be monitored to ensure consistent levels of confidence in the procedure. This paper reviews the currently recommended test guidelines and test phantoms for ultrasound systems used in prostate brachytherapy from the different standard bodies and professional organisations. A critical analysis of those tests which are most reflective of the imaging and guidance tasks undertaken in an ultrasound guided prostate brachytherapy procedure will also be presented to inform the design of a TRUS quality assurance protocol. Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  6. Experience in the diagnostic and surgical treatment of pancreatic pseudocysts

    Directory of Open Access Journals (Sweden)

    N. G. Golovko

    2015-10-01

    Full Text Available Actuality. Problem of surgical treatment of pancreatic pseudocysts is actual and debatable. The incidence of pancreatic pseudocysts is 0.5–1 per 100 000 adults per year, and in the overall incidence it reaches 1.6% –4.5%. Aim. Surgical treatment results of 34 patients with pancreatic pseudocysts were analyzed to improve results of diagnostic and surgical management of pancreatic pseudocests. Methods and results. Ultrasound scan combined with computer tomography were used for pancreatic pseudocysts diagnostic. Pancreatic pseudocysts surgical treatment was performed by minimally invasive percutaneous techniques and laparotomic surgery. Laparotomy operations were performed in 27 patients. The structure of operations was follow: external drainage of pseudocysts - 11 patients, 2 of them by minilaparotomy access, pseudocyst jejunostomy by Roux – 9 patients, pseudocyst jejunostomy with entero-enteroanastamosis by Brown – 3 patients, pseudocyst gastrostomy and pseudocyst duodenostomy – in 2 patients. Percutaneous external drainage of pancreatic pseudocysts under ultrasound control was performed in 7 patients. Indications for external percutaneous needle drainage of pancreatic pseudocysts under ultrasound control were: presence of a secure acoustic windows, lack of communication with the pancreatic pseudocysts ductal system, pseudocyst cavity diameter greater than 60 mm with wall thickness more than 3–4 mm, presence of the severe comorbidity and high operational and anesthetic risk (III–IV class ASA. Conclusions. Analysis of early treatment results (3–6 months found that pancreatic pseudocysts minimally invasive percutaneous puncture external drainage use in combination with ultrasound control, in addition to laparotomic operation, allows to achieve excellent and good results in 91.1% of patients.

  7. Construction of modern Australian first trimester ultrasound dating and growth charts

    International Nuclear Information System (INIS)

    McLennan, A. C.; Schluter, P. J.; and the University of Queensland, Brisbane, Queensland Australia

    2008-01-01

    Full text: Accurate pregnancy dating is vital to obstetric management. However, first trimester fetal charts commonly used in Australia rely on data reported more than three decades ago. This study reports first trimester dating and growth charts for crown-rump length between 5 and 14 weeks of gestation and biparietal diameter between 9 and 14 weeks of gestation on an Australia population using modern real-time ultrasound equipment. All consenting eligible women attending a large Sydney clinic for first trimester ultrasound between March 2005 and December 2006 were recruited. Measurements were carried out to Australasian Society for Ultrasound in Medicine standard protocols. Statistical analyses were undertaken using polynomial regression models and thorough diagnostic checks made. Overall 396 eligible women consented to the study, with 268 between 9 and 14 weeks of gestation. The average participant age was 34 years (range 22-45 years), 371 and all yielded valid biometry measurements. Equations, means and 90% reference intervals for crown-rump length measurements and biparietal diameter measurements were derived using polynomial regression models. Thorough residual and diagnostic checks were made. Once validated by others, we believe they will warrant consideration for use by Australasian Society for Ultrasound in Medicine.

  8. Cranial ultrasound in neonates and infants in rural Africa

    African Journals Online (AJOL)

    birth asphyxia, suspected intracranial malformations, infections, trauma and ... the total catchment area.18-22 The prematurity rate is about 10%, but very premature .... The value of diagnostic ultrasound in developing country settings has ...

  9. Numerical Calculation and Measurement of Nonlinear Acoustic Fields in Ultrasound Diagnosis

    Science.gov (United States)

    Kawagishi, Tetsuya; Saito, Shigemi; Mine, Yoshitaka

    2002-05-01

    In order to develop a tool for designing on the ultrasonic probe and its peripheral devices for tissue-harmonic-imaging systems, a study is carried out to compare the calculation and observation results of nonlinear acoustic fields for a diagnostic ultrasound system. The pulsed ultrasound with a center frequency of 2.5 MHz is emanated from a weakly focusing sector probe with a 6.5 mm aperture radius and a 50 mm focal length into an agar phantom with an attenuation coefficient of about 0.6 dB/cm/MHz or 1.2 dB/cm/MHz. The nonlinear acoustic field is measured using a needle-type hydrophone. The calculation is based on the Khokhlov-Zabolotskaya-Kuznetsov(KZK) equation which is modified so that the frequency dependence of the attenuation coefficient is the same as that in biological tissue. This equation is numerically solved with the implicit backward method employing the iterative method. The measured and calculated amplitude spectra show good agreement with each other.

  10. Comparative analysis of diagnostic accuracy of different brain biopsy procedures.

    Science.gov (United States)

    Jain, Deepali; Sharma, Mehar Chand; Sarkar, Chitra; Gupta, Deepak; Singh, Manmohan; Mahapatra, A K

    2006-12-01

    Image-guided procedures such as computed tomography (CT) guided, neuronavigator-guided and ultrasound-guided methods can assist neurosurgeons in localizing the intraparenchymal lesion of the brain. However, despite improvements in the imaging techniques, an accurate diagnosis of intrinsic lesion requires tissue sampling and histological verification. The present study was carried out to examine the reliability of the diagnoses made on tumor sample obtained via different stereotactic and ultrasound-guided brain biopsy procedures. A retrospective analysis was conducted of all brain biopsies (frame-based and frameless stereotactic and ultrasound-guided) performed in a single tertiary care neurosciences center between 1995 and 2005. The overall diagnostic accuracy achieved on histopathology and correlation with type of biopsy technique was evaluated. A total of 130 cases were included, which consisted of 82 males and 48 females. Age ranged from 4 to 75 years (mean age 39.5 years). Twenty per cent (27 patients) were in the pediatric age group, while 12% (16 patients) were >or= 60-years of age. A definitive histological diagnosis was established in 109 cases (diagnostic yield 80.2%), which encompassed 101 neoplastic and eight nonneoplastic lesions. Frame-based, frameless stereotactic and ultrasound-guided biopsies were done in 95, 15 and 20 patients respectively. Although the numbers of cases were small there was trend for better yield with frameless image-guided stereotactic biopsy and maximum diagnostic yield was obtained i.e, 87% (13/15) in comparison to conventional frame-based CT-guided stereotactic biopsy and ultrasound-guided biopsy. Overall, a trend of higher diagnostic yield was seen in cases with frameless image-guided stereotactic biopsy. Thus, this small series confirms that frameless neuronavigator-guided stereotactic procedures represent the lesion sufficiently in order to make histopathologic diagnosis.

  11. IMPLEMENTATION OF TURNOUTS TECHNICAL DIAGNOSTICS SYSTEMS

    Directory of Open Access Journals (Sweden)

    S. YU. Buryak

    2015-06-01

    Full Text Available Purpose. In the paper it is necessary to: 1 find out the causes of turnouts faults to determine diagnostic features failures; 2 consider the requirements structure, purpose components of turnouts, work and technology of their maintenance to determine the construction of the economic activities related to system to the turnout’s maintenance; 3 substantiate the possibility, necessity and prospects of automated diagnostics turnout’s implementation; 4 elaborate a prototype of an automated hardware and software system for the turnouts control parameters and perform diagnostics on them. Methodology. In the paper possible turnouts faults were presented and manifestations and influence on its work were shown. According to the current technology works the process analyze of turnouts’ maintenance was conducted, were defined the basic performed operations during the examination of appearance, parameters and check the repair or replacement of parts and assemblies. Based on the analysis of reasons of turnouts malfunctioning and their fixes were systematized types of damages and ways to deal with them, an information scheme of troubleshooting were created, opportunities and limits of automating the process of diagnostics were identified and compared with the existing method of turnouts maintenance. A diagnostics system block diagram was created, an algorithm of its work was developed and established main basic principles of operation. Software and hardware to determine the turnout’s state considering diagnostic performance of points in use were applied. Findings. During the experiment was created a method of automated turnout’s diagnostics with AC electric drives, managed centrally. The results of automated hardware and software system make it possible to control turnout’s parameters and perform diagnostics on them. Originality. Authors created the method of turnout’s state determination by current curve and its spectral composition in the

  12. Ultrasound-triggered drug release from vibrating microbubbles

    NARCIS (Netherlands)

    Y. Luan (Ying)

    2014-01-01

    markdownabstract__Abstract__ Diagnostic medical ultrasound may have a slightly longer history than what you expected. Its root dates back to 1930s and 1940s, when Theodore Dussik, a psychiatrist and neurologist, and his brother Friederich used a 1.5 MHz source to record signal variations after

  13. Ultrasound Enhanced Matrix Metalloproteinase-9 Triggered Release of Contents from Echogenic Liposomes

    Science.gov (United States)

    Nahire, Rahul; Paul, Shirshendu; Scott, Michael D.; Singh, Raushan K.; Muhonen, Wallace W.; Shabb, John; Gange, Kara N.; Srivastava, D. K.; Sarkar, Kausik; Mallik, Sanku

    2012-01-01

    The extracellular enzyme matrix metalloproteinase-9 (MMP-9) is overexpressed in atherosclerotic plaques and in metastatic cancers. The enzyme is responsible for rupture of the plaques and for the invasion and metastasis of a large number of cancers. The ability of ultrasonic excitation to induce thermal and mechanical effects has been used to release drugs from different carriers. However, majority of these studies were performed with low frequency ultrasound (LFUS) at kHz frequencies. Clinical usage of LFUS excitations will be limited due to harmful biological effects. Herein, we report our results on the release of encapsulated contents from substrate lipopeptide incorporated echogenic liposomes triggered by recombinant human MMP-9. The contents release was further enhanced by the application of diagnostic frequency (3 MHz) ultrasound. The echogenic liposomes were successfully imaged employing a medical ultrasound transducer (4 – 15 MHz). The conditioned cell culture media from cancer cells (secreting MMP-9) released the encapsulated dye from the liposomes (30 – 50%) and this release is also increased (50 – 80%) by applying diagnostic frequency ultrasound (3 MHz) for 3 minutes. With further developments, these liposomes have the potential to serve as multimodal carriers for triggered release and simultaneous ultrasound imaging. PMID:22849291

  14. A REVIEW OF LOW-INTENSITY ULTRASOUND FOR CANCER THERAPY

    Science.gov (United States)

    WOOD, ANDREW K. W.; SEHGAL, CHANDRA M.

    2015-01-01

    The literature describing the use of low-intensity ultrasound in four major areas of cancer therapy was reviewed - sonodynamic therapy, ultrasound mediated chemotherapy, ultrasound mediated gene delivery and antivascular ultrasound therapy. Each technique consistently resulted in the death of cancer cells and the bioeffects of ultrasound were primarily attributed to thermal actions and inertial cavitation. In each therapeutic modality, theranostic contrast agents composed of microbubbles played a role in both therapy and vascular imaging. The development of these agents is important as it establishes a therapeutic-diagnostic platform which can monitor the success of anti-cancer therapy. Little attention, however, has been given to either the direct assessment of the underlying mechanisms of the observed bioeffects or to the viability of these therapies in naturally occurring cancers in larger mammals; if such investigations provided encouraging data there could be a prompt application of a therapy technique in treating cancer patients. PMID:25728459

  15. ATA diagnostic data handling system: an overview

    International Nuclear Information System (INIS)

    Chambers, F.W.; Kallman, J.; McDonald, J.; Slominski, M.

    1984-01-01

    The functions to be performed by the ATA diagnostic data handling system are discussed. The capabilities of the present data acquisition system (System 0) are presented. The goals for the next generation acquisition system (System 1), currently under design, are discussed. Facilities on the Octopus system for data handling are reviewed. Finally, we discuss what has been learned about diagnostics and computer based data handling during the past year

  16. Ultrasound guided pleural biopsy in undiagnosed exudative pleural effusion patients

    Directory of Open Access Journals (Sweden)

    Adel S. Ahmed

    2016-04-01

    In conclusion: Thoracic ultrasound (TUS guided pleural biopsy had a diagnostic yield which was slightly lower but comparable to both CT guided pleural biopsy and medical thoracoscopic pleural biopsy (MT.

  17. Ultrasound assisted combustion synthesis of TiC in Al-Ti-C system.

    Science.gov (United States)

    Liu, Zhiwei; Rakita, Milan; Xu, Wilson; Wang, Xiaoming; Han, Qingyou

    2015-11-01

    This research investigated the effects of high-intensity ultrasound on the combustion synthesis of TiC particles in Al-Ti-C system. The process involved that high-intensity ultrasound was applied on the surface of a compacted Al-Ti-C pellet directly through a Nb probe during the thermal explosion reaction. By comparing with the sample without ultrasonic treatment, it was found that the thermal explosion reaction for synthesizing TiC phase could take place thoroughly in the ultrasonically treated sample. During the process of synthesizing TiC phase, the dissolution of solid graphite particles into the Al-Ti melt, as well as the nucleation and growth of TiC particles could be promoted effectively due to the effects of ultrasound, leading to an enhancement of the formation of TiC particles. Ultrasound assisted combustion synthesis as a simple and effective approach was proposed for synthesizing materials in this research. Copyright © 2015 Elsevier B.V. All rights reserved.

  18. Has 4D transperineal ultrasound additional value over 2D transperineal ultrasound for diagnosing obstructed defaecation syndrome?

    Science.gov (United States)

    van Gruting, I M A; Kluivers, K; Sultan, A H; De Bin, R; Stankiewicz, A; Blake, H; Thakar, R

    2018-06-08

    To establish the diagnostic test accuracy of both two-dimensional (2D) and four-dimensional (4D) transperineal ultrasound, to assess if 4D ultrasound imaging provides additional value in the diagnosis of posterior pelvic floor disorders in women with obstructed defaecation syndrome. In this prospective cohort study, 121 consecutive women with obstructed defaecation syndrome were recruited. Symptoms of obstructed defaecation and signs of pelvic organ prolapse were assessed using validated methods. All women underwent both 2D transperineal ultrasound (Pro-focus, 8802 transducer, BK-medical) and 4D transperineal ultrasound (Voluson i, RAB4-8-RS transducer, GE). Imaging analysis was performed by two blinded observers. Pelvic floor disorders were dichotomised into presence or absence according pre-defined cut-off values. In the absence of a reference standard a composite reference standard was created from a combination of results of evacuation proctogram, magnetic resonance imaging and endovaginal ultrasound. Primary outcome measures were diagnostic test characteristics of 2D and 4D transperineal ultrasound for diagnosis or rectocele, enterocele, intussusception and anismus. Secondary outcome measures were interobserver agreement, agreement between the two techniques and correlation of signs and symptoms to imaging findings. For diagnosis of all four posterior pelvic floor disorders there was no difference in sensitivity and specificity between 2D and 4D TPUS (p= 0.131 - 1.000). A good agreement between 2D and 4D TPUS was found for the diagnosis of rectocele (ĸ 0.675) and a moderate agreement for diagnosis of enterocele, intussusception and anismus (ĸ 0.465 - 0.545). There was no difference in rectocele depth measurements between both TPUS techniques (19.9 mm vs 19.0 mm, p=0.802). Inter-observer agreement was comparable for both techniques, however 2D TPUS had an excellent interobserver agreement for diagnosis of enterocele and rectocele depth measurements. Diagnosis

  19. A Self-Diagnostic System for the M6 Accelerometer

    Science.gov (United States)

    Flanagan, Patrick M.; Lekki, John

    2001-01-01

    The design of a Self-Diagnostic (SD) accelerometer system for the Space Shuttle Main Engine is presented. This retrofit system connects diagnostic electronic hardware and software to the current M6 accelerometer system. This paper discusses the general operation of the M6 accelerometer SD system and procedures for developing and evaluating the SD system. Signal processing techniques using M6 accelerometer diagnostic data are explained. Test results include diagnostic data responding to changing ambient temperature, mounting torque and base mounting impedance.

  20. Diagnostic performances of shear wave elastography: which parameter to use in differential diagnosis of solid breast masses?

    Science.gov (United States)

    Lee, Eun Jung; Jung, Hae Kyoung; Ko, Kyung Hee; Lee, Jong Tae; Yoon, Jung Hyun

    2013-07-01

    To evaluate which shear wave elastography (SWE) parameter proves most accurate in the differential diagnosis of solid breast masses. One hundred and fifty-six breast lesions in 139 consecutive women (mean age: 43.54 ± 9.94 years, range 21-88 years), who had been scheduled for ultrasound-guided breast biopsy, were included. Conventional ultrasound and SWE were performed in all women before biopsy procedures. Ultrasound BI-RADS final assessment and SWE parameters were recorded. Diagnostic performance of each SWE parameter was calculated and compared with those obtained when applying cut-off values of previously published data. Performance of conventional ultrasound and ultrasound combined with each parameter was also compared. Of the 156 breast masses, 120 (76.9 %) were benign and 36 (23.1 %) malignant. Maximum stiffness (Emax) with a cut-off of 82.3 kPa had the highest area under the receiver operating characteristics curve (Az) value compared with other SWE parameters, 0.860 (sensitivity 88.9 %, specificity 77.5 %, accuracy 80.1 %). Az values of conventional ultrasound combined with each SWE parameter showed lower (but not significantly) values than with conventional ultrasound alone. Maximum stiffness (82.3 kPa) provided the best diagnostic performance. However the overall diagnostic performance of ultrasound plus SWE was not significantly better than that of conventional ultrasound alone. • SWE offers new information over and above conventional breast ultrasound • Various SWE parameters were explored regarding distinction between benign and malignant lesions • An elasticity of 82.3 kPa appears optimal in differentiating solid breast masses • However, ultrasound plus SWE was not significantly better than conventional ultrasound alone.

  1. Reliability and diagnostic of modular systems

    Directory of Open Access Journals (Sweden)

    J. Kohlas

    2014-01-01

    Full Text Available Reliability and diagnostic are in general two problems discussed separately. Yet the two problems are in fact closely related to each other. Here, this relation is considered in the simple case of modular systems. We show, how the computation of reliability and diagnostic can efficiently be done within the same Bayesian network induced by the modularity of the structure function of the system.

  2. Hybrid case-neural network (CNN) diagnostic system

    International Nuclear Information System (INIS)

    Mohamed, A.H.

    2010-01-01

    recently, the mobile health care has a great attention for the researcher and people all over the world. Case based reasoning (CBR) systems have proved their performance as world wide web (WWW) medical diagnostic systems. They were preferred rather than different reasoning approaches due to their high performance and results' explanation. But, their operations require a complex knowledge acquisition and management processes. On the other hand, it is found that, artificial neural network (ANN) has a great acceptance as a classifier methodology using a little amount of knowledge. But, ANN lacks of an explanation capability .The present research introduces a new web-based hybrid diagnostic system that can use the ANN inside the CBR , cycle.It can provide higher performance for the web diagnostic systems. Besides, the proposed system can be used as a web diagnostic system. It can be applied for diagnosis different types of systems in several domains. It has been applied in diagnosis of the cancer diseases that has a great spreading in recent years as a case of study . However, the suggested system has proved its acceptance in the manner.

  3. Renal candidiasis in newborn: the ultrasonography as diagnostic and therapeutic method

    International Nuclear Information System (INIS)

    Lopez Pino, M.A.; Serrano Hernandez, C.; Alba Romero, C.; Aransay Bramtot, A.; Paul Diaz, L.

    1995-01-01

    We present a case of systemic candidiasis in a low-weight newborn. Renal involvement presented as unilateral hydronephrosis secondary to the fungal construction. Ultrasound served not only as a diagnostic tool, but as a guide for the performance of performance of percutaneous nephrostomy which was included in the therapeutic approach to decompress the excretory pathway and allow local installation of anti fungal agents. (Author) 16 refs

  4. Diagnostic accuracy of 22/25-gauge core needle in endoscopic ultrasound-guided sampling: systematic review and meta-analysis.

    Science.gov (United States)

    Oh, Hyoung-Chul; Kang, Hyun; Lee, Jae Young; Choi, Geun Joo; Choi, Jung Sik

    2016-11-01

    To compare the diagnostic accuracy of endoscopic ultrasound-guided core needle aspiration with that of standard fine-needle aspiration by systematic review and meta-analysis. Studies using 22/25-gauge core needles, irrespective of comparison with standard fine needles, were comprehensively reviewed. Pooled sensitivity, specificity, diagnostic odds ratio (DOR), and summary receiver operating characteristic curves for the diagnosis of malignancy were used to estimate the overall diagnostic efficiency. The pooled sensitivity, specificity, and DOR of the core needle for the diagnosis of malignancy were 0.88 (95% confidence interval [CI], 0.84 to 0.90), 0.99 (95% CI, 0.96 to 1), and 167.37 (95% CI, 65.77 to 425.91), respectively. The pooled sensitivity, specificity, and DOR of the standard needle were 0.84 (95% CI, 0.79 to 0.88), 1 (95% CI, 0.97 to 1), and 130.14 (95% CI, 34.00 to 495.35), respectively. The area under the curve of core and standard needle in the diagnosis of malignancy was 0.974 and 0.955, respectively. The core and standard needle were comparable in terms of pancreatic malignancy diagnosis. There was no significant difference in procurement of optimal histologic cores between core and standard needles (risk ratio [RR], 0.545; 95% CI, 0.187 to 1.589). The number of needle passes for diagnosis was significantly lower with the core needle (standardized mean difference, -0.72; 95% CI, -1.02 to -0.41). There were no significant differences in overall complications (RR, 1.26; 95% CI, 0.34 to 4.62) and technical failure (RR, 5.07; 95% CI, 0.68 to 37.64). Core and standard needles were comparable in terms of diagnostic accuracy, technical performance, and safety profile.

  5. Potential and problems in ultrasound-responsive drug delivery systems

    Directory of Open Access Journals (Sweden)

    Zhao YZ

    2013-04-01

    Full Text Available Ying-Zheng Zhao,1,3 Li-Na Du,2 Cui-Tao Lu,1 Yi-Guang Jin,2 Shu-Ping Ge3 1Wenzhou Medical College, Wenzhou City, Zhejiang Province, 2Department of Pharmaceutical Sciences, Beijing Institute of Radiation Medicine, Beijing, People’s Republic of China; 3St Christopher’s Hospital for Children/Drexel University College of Medicine, Philadelphia, PA, USA Abstract: Ultrasound is an important local stimulus for triggering drug release at the target tissue. Ultrasound-responsive drug delivery systems (URDDS have become an important research focus in targeted therapy. URDDS include many different formulations, such as microbubbles, nanobubbles, nanodroplets, liposomes, emulsions, and micelles. Drugs that can be loaded into URDDS include small molecules, biomacromolecules, and inorganic substances. Fields of clinical application include anticancer therapy, treatment of ischemic myocardium, induction of an immune response, cartilage tissue engineering, transdermal drug delivery, treatment of Huntington’s disease, thrombolysis, and disruption of the blood–brain barrier. This review focuses on recent advances in URDDS, and discusses their formulations, clinical application, and problems, as well as a perspective on their potential use in the future. Keywords: ultrasound, targeted therapy, clinical application

  6. Diagnostic accuracy and patient acceptance of MRI in children with suspected appendicitis

    Energy Technology Data Exchange (ETDEWEB)

    Thieme, Mai E.; Valdehueza, Zaldy D.; Wiarda, Bart M. [Medical Centre Alkmaar, Department of Radiology, Alkmaar (Netherlands); Leeuwenburgh, Marjolein M.N. [Academic Medical Centre Amsterdam, Department of Radiology, Amsterdam (Netherlands); Academic Medical Centre Amsterdam, Department of Surgery, Amsterdam (Netherlands); Bouman, Donald E. [Medical Spectrum Twente, Department of Radiology, Enschede (Netherlands); Bruin, Ivar G.J.M. de; Schreurs, W.H.; Houdijk, Alexander P.J. [Medical Centre Alkmaar, Department of Surgery, Alkmaar (Netherlands); Stoker, Jaap [Academic Medical Centre Amsterdam, Department of Radiology, Amsterdam (Netherlands)

    2014-03-15

    To compare magnetic resonance imaging (MRI) and ultrasound in children with suspected appendicitis. In a single-centre diagnostic accuracy study, children with suspected appendicitis were prospectively identified at the emergency department. All underwent abdominal ultrasound and MRI within 2 h, with the reader blinded to other imaging findings. An expert panel established the final diagnosis after 3 months. We evaluated the diagnostic accuracy of three imaging strategies: ultrasound only, conditional MRI after negative or inconclusive ultrasound, and MRI only. Significance between sensitivity and specificity was calculated using McNemar's test statistic. Between April and December 2009 we included 104 consecutive children (47 male, mean age 12). According to the expert panel, 58 patients had appendicitis. The sensitivity of MRI only and conditional MRI was 100 % (95 % confidence interval 92-100), that of ultrasound was significantly lower (76 %; 63-85, P < 0.001). Specificity was comparable among the three investigated strategies; ultrasound only 89 % (77-95), conditional MRI 80 % (67-89), MRI only 89 % (77-95) (P values 0.13, 0.13 and 1.00). In children with suspected appendicitis, strategies with MRI (MRI only, conditional MRI) had a higher sensitivity for appendicitis compared with a strategy with ultrasound only, while specificity was comparable. (orig.)

  7. Radiation effects in IFMIF Li target diagnostic systems

    International Nuclear Information System (INIS)

    Molla, J.; Vila, R.; Shikama, T.; Horiike, H.; Simakov, S.; Ciotti, M.; Ibarra, A.

    2009-01-01

    Diagnostics for the lithium target will be crucial for the operation of IFMIF. Several parameters as the lithium temperature, target thickness or wave pattern must be monitored during operation. Radiation effects may produce malfunctioning in any of these diagnostics due to the exposure to high radiation fields. The main diagnostic systems proposed for the operation of IFMIF are reviewed in this paper from the point of view of radiation damage. The main tools for the assessment of the performance of these diagnostics are the neutronics calculations by using specialised codes and the information accumulated during the last decades on the radiation effects in functional materials, components and diagnostics for ITER. This analysis allows to conclude that the design of some of the diagnostic systems must be revised to assure the high availability required for the target system.

  8. Chest radiography and abdominal ultrasound in general practice

    NARCIS (Netherlands)

    Speets, Anouk Mariëlle

    2006-01-01

    Chest radiography (CXR) and abdominal ultrasound (US) are two widely used diagnostic imaging techniques in Western societies. General practitioners (GPs) in The Netherlands annually request approximately 500,000 CXRs and 200,000 abdominal US, and therefore clearly place a burden on health care.

  9. MFTF plasma diagnostics data acquisition system

    International Nuclear Information System (INIS)

    Davis, G.E.; Coffield, F.E.

    1979-01-01

    The initial goal of the Data Acquisition System (DAS) is to control 11 instruments chosen as the startup diagnostic set and to collect, process, and display the data that these instruments produce. These instruments are described in a paper by Stan Thomas, et. al. entitled ''MFTF Plasma Diagnostics System.'' The DAS must be modular and flexible enough to allow upgrades in the quantity of data taken by an instrument, and also to allow new instruments to be added to the system. This is particularly necessary to support a research project where needs and requirements may change rapidly as a result of experimental findings. Typically, the startup configuration of the diagnostic instruments will contain only a fraction of the planned detectors, and produce approximately one half the data that the expanded version is designed to generate. Expansion of the system will occur in fiscal year 1982

  10. Residual heat removal system diagnostic advisor

    International Nuclear Information System (INIS)

    Tripp, L.

    1991-01-01

    This paper reports on the Residual Heat Removal System (RHRS) Diagnostic Advisor which is an expert system designed to alert the operators to abnormal conditions that exits in the RHRS and offer advice about the cause of the abnormal conditions. The Advisor uses a combination of rule-based and model-based diagnostic techniques to perform its functions. This diagnostic approach leads to a deeper understanding of the RHRS by the Advisor and consequently makes it more robust to unexpected conditions. The main window of the interactive graphic display is a schematic diagram of the RHRS piping system. When a conclusion about a failed component can be reached, the operator can bring up windows that describe the failure mode of the component and a brief explanation about how the Advisor arrived at its conclusion

  11. Portable Ultrasound Imaging

    DEFF Research Database (Denmark)

    di Ianni, Tommaso

    This PhD project investigates hardware strategies and imaging methods for hand-held ultrasound systems. The overall idea is to use a wireless ultrasound probe linked to general-purpose mobile devices for the processing and visualization. The approach has the potential to reduce the upfront costs...... beamforming strategies are simulated from a system-level perspective. The quality of the B-mode image is evaluated and the minimum specifications are derived for the design of a portable probe with integrated electronics in-handle. The system is based on a synthetic aperture sequential beamforming approach...... that allows to significantly reduce the data rate between the probe and processing unit. The second part investigates the feasibility of vector flow imaging in a hand-held ultrasound system. Vector flow imaging overcomes the limitations of conventional imaging methods in terms of flow angle compensation...

  12. Mesh three-dimensional arm orthosis with built-in ultrasound physiotherapy system

    Science.gov (United States)

    Kashapova, R. M.; Kashapov, R. N.; Kashapova, R. S.

    2017-09-01

    The possibility of using the built-in ultrasound physiotherapy system of the hand orthosis is explored in the work. The individual mesh orthosis from nylon 12 was manufactured by the 3D prototyping method on the installation of selective laser sintering SLS SPro 60HD. The applied technology of three-dimensional scanning made it possible to obtain a model of the patient’s hand and on the basis of it to build a virtual model of the mesh frame. In the course of the research, the developed system of ultrasound exposure was installed on the orthosis and its tests were carried out. As a result, the acceleration of the healing process and the reduction in the time of wearing orthosis were found.

  13. NPP Mochovce units 1 and 2 diagnostic systems

    International Nuclear Information System (INIS)

    Heidenreich, S.

    1997-01-01

    In this paper the diagnostic systems (leak detection monitoring, vibration monitoring, lose parts monitoring, fatigue monitoring) of NPP Mochovce units 1 and 2 are presented. All of the designed diagnostic systems are personal computer based systems

  14. Ultrasound-guided forceps for pleural biopsy

    Directory of Open Access Journals (Sweden)

    Gamal Agmy

    2014-04-01

    Clinical implications: Ultrasound-guided forceps for pleural biopsy can overcome many of the limitations of the conventional needle biopsy procedures, provides multiple biopsy specimens of the parietal pleura that are inaccessible to the biopsy needle, and can be carried out easily and safely even in sick and obese patients. The diagnostic yield is nearly similar to thoracoscopy.

  15. Mechatronics in design of monitoring and diagnostic systems

    Energy Technology Data Exchange (ETDEWEB)

    Uhl, T.; Barszcz, T. [Univ. of Mining and Metallurgy, Krakow (Poland); Hanc, A. [Energocontrol Ltd., Krakow (Poland)

    2003-07-01

    Nowadays development of computer engineering in area of hardware and software gives new possibilities of monitoring and diagnostics system design. The paper presents analysis of new possible solutions for design of monitoring and diagnostic systems including; smart sensor design, modular software design and communication modules. New concept of monitoring system based on home page server solution (nano-server) is presented. Smart sensor design concept with embedded hardware for diagnostic application is shown. New software concept for monitoring and diagnostics automation and examples of applications of new design for condition monitoring based on proposed solution are carefully discussed. (orig.)

  16. Vascular ultrasound.

    Science.gov (United States)

    Pilcher, D B; Ricci, M A

    1998-04-01

    Surgeon-interpreted diagnostic ultrasound has become the preferred screening test and often the definitive test for the diagnosis of arterial stenosis, aneurysm, and venous thrombosis. As a modality for surveillance, its noninvasive quality makes it particularly appealing as the test of choice to screen patients for abdominal aortic aneurysms or to perform follow-up examinations on those patients with a carotid endartectomy or in situ bypass grafts. The increasing reliance on intraoperative duplex imaging of vascular procedures demands that the surgeon learn the skills to perform the studies without a technologist or radiologist to interpret the examination.

  17. Imaging systems for medical diagnostics

    International Nuclear Information System (INIS)

    Krestel, E.

    1990-01-01

    This book provides physicians and clinical physicists with detailed information on today's imaging modalities and assists them in selecting the optimal system for each clinical application. Physicists, engineers and computer specialists engaged in research and development and sales departments will also find this book to be of considerable use. It may also be employed at universities, training centers and in technical seminars. The physiological and physical fundamentals are explained in part 1. The technical solutions contained in part 2 illustrate the numerous possibilities available in X-ray diagnostics, computed tomography, nuclear medical diagnostics, magnetic resonance imaging, sonography and biomagnetic diagnostics. (orig.)

  18. Ultrasound guided core biopsy of suspicious mammographic calcifications using high frequency and power Doppler ultrasound

    International Nuclear Information System (INIS)

    Teh, W.L.; Wilson, A.R.M; Evans, A.J.; Burrell, H.; Pinder, S.E.; Ellis, I.O.

    2000-01-01

    AIM: The pre-operative diagnosis of suspicious mammographic microcalcifications usually requires stereotactic needle biopsy. The aim of this study was to evaluate if high frequency 13 MHz ultrasound (HFUS) and power Doppler (PD) can aid visualization and biopsy of microcalcifications. MATERIALS AND METHODS: Forty-four consecutive patients presenting with microcalcifications without associated mammographic or palpable masses were examined with HFUS and PD. Ultrasound-guided core biopsy (USCB) was performed where possible. Stereotactic biopsy was carried out when US-guided biopsy was unsuccessful. Surgery was performed if a diagnosis of malignancy was made on core biopsy or if the repeat core biopsy was non-diagnostic. RESULTS: Forty-one patients (93%) had ultrasound abnormalities corresponding to mammographic calcification. USCB was performed on 37 patients. In 29/37, USCB obtained a definitive result (78.4%). USCB was non-diagnostic in 4/9 benign (44.4%) and 4/28 (14.3%) malignant lesions biopsied. The complete and absolute sensitivities for malignancy using USCB were 85.7% (24/28) and 81% (23/28), respectively. USCB correctly identified invasive disease in 12/23 (52.2%) cases. There was no significant difference in the presence of abnormal flow on PD between benign and malignant lesions. However, abnormal PD vascularity was present in 43.5% of invasive cancer and was useful in directing successful biopsy in eight cases. CONCLUSION: The combination of high frequency US with PD is useful in the detection and guidance of successful needle biopsy of microcalcifications particularly where there is an invasive focus within larger areas of DCIS. Teh, W.L. (2000)

  19. Jaundice: a preliminary study with the ultrasound

    International Nuclear Information System (INIS)

    Chen Xiang; Sun Jian; Liu Haiping; Luo Weiquan

    2006-01-01

    Objective: To evaluate the ultrasound in imaging diagnosis of jaundice. Methods: The changes of ultrasonography of 116 patients with jaundice were correlatively studied with the final diagnosis. Results: Hepatocellular jaundice was found in 27 cases out of 116; and obstructive jaundice was revealed in other 89 cases. The level of obstruction was correctly assessed by ultrasound in 94.2% of the patients. The primary lesion was successfully identified by ultrasound in 87.6% cases of obstructive jaundice. Misdiagnosis was made in 8 cases. Conclusion: Ultrasonography can confirm the obstructive jaundice. The level of obstruction can be precisely located and the primary lesions can be correctly identified in most cases. Better understanding the sonographic characteristics of benign disorder such as inflam-matory mass of caput of pancreas and inflammatory stricture of common bile duct results in a higher diagnostic accuracy. (authors)

  20. Impact of antepartum diagnostic amnioinfusion on targeted ultrasound imaging of pregnancies presenting with severe oligo- and anhydramnios: An analysis of 61 cases.

    Science.gov (United States)

    Vikraman, Seneesh Kumar; Chandra, Vipin; Balakrishnan, Bijoy; Batra, Meenu; Sethumadhavan, Sreeja; Patil, Swapneel Neelkanth; Nair, Sabila; Kannoly, Gopinathan

    2017-05-01

    The primary objective our study was to assess the role of diagnostic antepartum amnioinfusion on the yield from targeted ultrasounds performed in pregnancies with severe oligo- and anhydramnios. This was a retrospective and descriptive study, conducted in the fetal medicine units of two private tertiary care referral centers in south India. The details of all the cases of diagnostic amnioinfusion performed at these two centers from January 2009 to June 2016 were collected and analyzed. Inclusion criteria were pregnancies between 17 and 26 weeks of gestational age with severe oligo- or anhydramnios. Pregnancies with obvious preterm premature rupture of membranes (PPROM) were excluded. The primary outcome measure was the improvement in diagnostic information pertaining to cause of severe oligo- and anhydramnios, and the nature of such anomalies. A total of 61 cases of were identified. The median gestational age at performance of the procedure was 22 weeks [IQR, 19.5-23]. The mean volume of normal saline infused was 314±54ml. A significant increase in the single vertical pocket (SVP) was observed following the procedure (pre-procedure SVP=0.6±0.9cm, post procedure SVP=3.4±1.7; paired t test, pamnioinfusion is a valuable ancillary technique in prenatal diagnosis as it increases the diagnostic yield from pregnancies presenting with severe oligo- and anhydramnios. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. THE POTENTIAL VALUE OF ULTRASOUND IN DIAGNOSIS OF SOFT TISSUE SARCOMA (LITERATURE REVIEW

    Directory of Open Access Journals (Sweden)

    I. G. Frolova

    2015-01-01

    Full Text Available Literature data on the potential value of ultrasound imaging in diagnosis of soft tissue sarcoma were analyzed. Ultrasound in B-regime was used to assess the extent of soft tissue sarcoma, Doppler ultrasonography was used to study tumor vascularization and sonoelastography was useful to differentiate benign from malignant tumors of soft tissues. The analysis of diagnostic value of ultrasound in detection of soft tissue lesions was carried out.  Criteria characterizing various histological types of tumors were identified.

  2. An easy-to-use diagnostic system development shell

    Science.gov (United States)

    Tsai, L. C.; Ross, J. B.; Han, C. Y.; Wee, W. G.

    1987-01-01

    The Diagnostic System Development Shell (DSDS), an expert system development shell for diagnostic systems, is described. The major objective of building the DSDS is to create a very easy to use and friendly environment for knowledge engineers and end-users. The DSDS is written in OPS5 and CommonLisp. It runs on a VAX/VMS system. A set of domain independent, generalized rules is built in the DSDS, so the users need not be concerned about building the rules. The facts are explicitly represented in a unified format. A powerful check facility which helps the user to check the errors in the created knowledge bases is provided. A judgement facility and other useful facilities are also available. A diagnostic system based on the DSDS system is question driven and can call or be called by other knowledge based systems written in OPS5 and CommonLisp. A prototype diagnostic system for diagnosing a Philips constant potential X-ray system has been built using the DSDS.

  3. Radiological evaluation of the fetal face using three-dimensional ultrasound imaging

    Directory of Open Access Journals (Sweden)

    Bäumler M

    2012-12-01

    Full Text Available Marcel Bäumler,1–3 Michèle Bigorre,1,4 Jean-Michel Faure1,51CHU Montpellier, Centre de Compétence des Fentes Faciales, Hôpital Lapeyronie, Montpellier, 2Clinique du Parc, Imagerie de la Femme, Castelnau-le-Lez, 3Cabinet de Radiologie du Trident, Lunel, 4CHU Service de Chirurgie Plastique Pédiatrique, Hôpital Lapeyronie, Montpellier, 5CHU Montpellier, Service de Gynécologie-Obstétrique, Hôpital Arnaud de Villeneuve, Montpellier, FranceAbstract: This paper reviews screening and three-dimensional diagnostic ultrasound imaging of the fetal face. The different techniques available for analyzing biometric and morphological items of the profile, eyes, ears, lips, and hard and soft palate are commented on and briefly compared with the respective bi-dimensional techniques. The available literature supports the use of three-dimensional ultrasound in difficult prenatal diagnostic conditions because of its diagnostic accuracy, enabling improved safety of perinatal care. Globally, a marked increase has been observed in the accuracy of three-dimensional ultrasound in comparison with the bi-dimensional approach. Because there is no consensus about the performance of the different three-dimensional techniques, future studies are needed in order to compare them and to find the best technique for analysis of each of the respective facial elements. Universal prenatal standards may integrate these potential new findings in the future. At this time, the existing guidelines for prenatal facial screening should not be changed.Keywords: prenatal three-dimensional ultrasound, prenatal screening, prenatal diagnosis, cleft lip and palate, fetal profile, retrognathism

  4. Application of contrast-enhanced ultrasound in the diagnosis of solid pancreatic lesions—A comparison of conventional ultrasound and contrast-enhanced CT

    International Nuclear Information System (INIS)

    Fan, Zhihui; Li, Ying; Yan, Kun; Wu, Wei; Yin, Shanshan; Yang, Wei; Xing, Baocai

    2013-01-01

    Objective: To explore the diagnostic value of contrast-enhanced ultrasound (CEUS) by comparison with conventional ultrasound (US) and contrast-enhanced CT (CECT) in solid pancreatic lesions. Method: Ninety patients with solid pancreatic focal lesions were enrolled, including 36 cases of pancreatic carcinoma, 28 cases of pancreatitis, 6 cases of pancreatic neuroendocrine tumor, 12 cases of solid pseudopapillary tumor of the pancreas, 6 cases of pancreatic metastases, 1 case of cavernous hemolymphangioma and 1 case of lymphoma. US and CEUS were applied respectively for the diagnosis of a total of 90 cases of solid pancreatic lesions. The diagnostic results were scored on a 5-point scale. Results of CEUS were compared with CECT. Results: (1) 3-score cases (undetermined) diagnosed by CEUS were obviously fewer than that of US, while the number of 1-score (definitely benign) and 5-score (definitely malignant) cases diagnosed by CEUS was significantly more than that of US. There was a significant difference in the distribution of final scores using the two methods (p < 0.001). The overall diagnostic accuracies of the 90 cases for CEUS and US were 83.33% and 44.44%, respectively, which indicated an obvious advantage for CEUS (p < 0.001). (2) The diagnostic consistency among three ultrasound doctors: the kappa values calculated for US were 0.537, 0.444 and 0.525, compared with 0.748, 0.645 and 0.795 for CEUS. The interobserver agreement for CEUS was higher than that for US. (3) The sensitivity, specificity and accuracy of the diagnosis of pancreatic carcinoma with CEUS and CECT were 91.7% and 97.2%, 87.0% and 88.9%, and 88.9% and 92.2%, respectively, while for the diagnosis of pancreatitis, the corresponding indices were 82.1% and 67.9%, 91.9% and 100%, and 88.9% and 90%, respectively, showing no significant differences (p > 0.05). Conclusion: CEUS has obvious superiority over conventional US in the general diagnostic accuracy of solid pancreatic lesions and in the

  5. Application of contrast-enhanced ultrasound in the diagnosis of solid pancreatic lesions—A comparison of conventional ultrasound and contrast-enhanced CT

    Energy Technology Data Exchange (ETDEWEB)

    Fan, Zhihui, E-mail: fanzhihui_1026@163.com [Key Laboratory of Carcinogenesis and Translational Research, Ministry of Education, Department of Ultrasound, Peking University Cancer Hospital and Institute, No. 52, Fucheng Road, Haidian District, Beijing 100142 (China); Li, Ying, E-mail: 18901033676@126.com [Key Laboratory of Carcinogenesis and Translational Research, Ministry of Education, Department of Radiology, Peking University Cancer Hospital and Institute, No. 52, Fucheng Road, Haidian District, Beijing 100142 (China); Yan, Kun, E-mail: ydbz@sina.com [Key Laboratory of Carcinogenesis and Translational Research, Ministry of Education, Department of Ultrasound, Peking University Cancer Hospital and Institute, No. 52, Fucheng Road, Haidian District, Beijing 100142 (China); Wu, Wei, E-mail: wuwei@163.com [Key Laboratory of Carcinogenesis and Translational Research, Ministry of Education, Department of Ultrasound, Peking University Cancer Hospital and Institute, No. 52, Fucheng Road, Haidian District, Beijing 100142 (China); Yin, Shanshan, E-mail: yshshmd@yahoo.com [Key Laboratory of Carcinogenesis and Translational Research, Ministry of Education, Department of Ultrasound, Peking University Cancer Hospital and Institute, No. 52, Fucheng Road, Haidian District, Beijing 100142 (China); Yang, Wei, E-mail: weiwei02032001@gmail.com [Key Laboratory of Carcinogenesis and Translational Research, Ministry of Education, Department of Ultrasound, Peking University Cancer Hospital and Institute, No. 52, Fucheng Road, Haidian District, Beijing 100142 (China); Xing, Baocai, E-mail: xinbaocai88@sina.com [Key Laboratory of Carcinogenesis and Translational Research, Ministry of Education, Department of Hepatic Biliary and Pancreatic Surgery, Peking University Cancer Hospital and Institute, No. 52, Fucheng Road, Haidian District, Beijing 100142 (China); and others

    2013-09-15

    Objective: To explore the diagnostic value of contrast-enhanced ultrasound (CEUS) by comparison with conventional ultrasound (US) and contrast-enhanced CT (CECT) in solid pancreatic lesions. Method: Ninety patients with solid pancreatic focal lesions were enrolled, including 36 cases of pancreatic carcinoma, 28 cases of pancreatitis, 6 cases of pancreatic neuroendocrine tumor, 12 cases of solid pseudopapillary tumor of the pancreas, 6 cases of pancreatic metastases, 1 case of cavernous hemolymphangioma and 1 case of lymphoma. US and CEUS were applied respectively for the diagnosis of a total of 90 cases of solid pancreatic lesions. The diagnostic results were scored on a 5-point scale. Results of CEUS were compared with CECT. Results: (1) 3-score cases (undetermined) diagnosed by CEUS were obviously fewer than that of US, while the number of 1-score (definitely benign) and 5-score (definitely malignant) cases diagnosed by CEUS was significantly more than that of US. There was a significant difference in the distribution of final scores using the two methods (p < 0.001). The overall diagnostic accuracies of the 90 cases for CEUS and US were 83.33% and 44.44%, respectively, which indicated an obvious advantage for CEUS (p < 0.001). (2) The diagnostic consistency among three ultrasound doctors: the kappa values calculated for US were 0.537, 0.444 and 0.525, compared with 0.748, 0.645 and 0.795 for CEUS. The interobserver agreement for CEUS was higher than that for US. (3) The sensitivity, specificity and accuracy of the diagnosis of pancreatic carcinoma with CEUS and CECT were 91.7% and 97.2%, 87.0% and 88.9%, and 88.9% and 92.2%, respectively, while for the diagnosis of pancreatitis, the corresponding indices were 82.1% and 67.9%, 91.9% and 100%, and 88.9% and 90%, respectively, showing no significant differences (p > 0.05). Conclusion: CEUS has obvious superiority over conventional US in the general diagnostic accuracy of solid pancreatic lesions and in the

  6. MTX [Microwave Tokamak Experiment] plasma diagnostic system

    International Nuclear Information System (INIS)

    Rice, B.W.; Hooper, E.B.; Brooksby, C.A.

    1987-01-01

    In this paper, a general overview of the MTX plasma diagnostics system is given. This includes a description of the MTX machine configuration and the overall facility layout. The data acquisition system and techniques for diagnostic signal transmission are also discussed. In addition, the diagnostic instruments planned for both an initial ohmic-heating set and a second FEL-heating set are described. The expected range of plasma parameters along with the planned plasma measurements will be reviewed. 7 refs., 5 figs

  7. PVT Degradation Studies: Acoustic Diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Dib, Gerges [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Tucker, Brian J. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Kouzes, Richard T. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Smith, Philip J. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2017-04-01

    Under certain environmental conditions, polyvinyl toluene (PVT) plastic scintillator has been observed to undergo internal fogging. This document reports on a study of acoustic techniques to determine whether they can provide a diagnostic for the fogging of PVT. Different ultrasound techniques were employed for detecting the level of internal fogging in PVT, including wave velocity measurements, attenuation, nonlinear acoustics, and acoustic microscopy. The results indicate that there are linear relations between the wave velocity and wave attenuation with the level of internal fogging. The effects of fogging on ultrasound wave attenuation is further verified by acoustic microscopy imaging, where regions with fog in the specimen demonstration higher levels of attenuation compared to clear regions. Results from the nonlinear ultrasound measurements were inconclusive due to high sensitivities to transducer coupling and fixture variabilities.

  8. Ultrasound skin tightening.

    Science.gov (United States)

    Minkis, Kira; Alam, Murad

    2014-01-01

    Ultrasound skin tightening is a noninvasive, nonablative method that allows for energy deposition into the deep dermal and subcutaneous tissue while avoiding epidermal heating. Ultrasound coagulation is confined to arrays of 1-mm(3) zones that include the superficial musculoaponeurotic system and connective tissue. This technology gained approval from the Food and Drug Administration as the first energy-based skin "lifting" device, specifically for lifting lax tissue on the neck, submentum, and eyebrows. Ultrasound has the unique advantage of direct visualization of treated structures during treatment. Ultrasound is a safe and efficacious treatment for mild skin tightening and lifting. Copyright © 2014 Elsevier Inc. All rights reserved.

  9. Medical ultrasound imaging

    DEFF Research Database (Denmark)

    Jensen, Jørgen Arendt

    2007-01-01

    The paper gives an introduction to current medical ultrasound imaging systems. The basics of anatomic and blood flow imaging are described. The properties of medical ultrasound and its focusing are described, and the various methods for two- and three-dimensional imaging of the human anatomy...

  10. Performance of hand-held whole-breast ultrasound based on BI-RADS in women with mammographically negative dense breast

    International Nuclear Information System (INIS)

    Youk, Ji Hyun; Kim, Eun-Kyung; Kim, Min Jung; Kwak, Jin Young; Son, Eun Ju

    2011-01-01

    To assess the performance of breast ultrasound based on BI-RADS final assessment categories in women with mammographically negative dense breast. Of 3,820 cases with mammographically negative dense breast and subsequent hand-held bilateral whole-breast ultrasound, a total of 1,507 cases in 1,046 women who had biopsy or at least 2-year follow-up ultrasound constituted the basis of this retrospective study. Cancer rate of each sonographic BI-RADS category was determined and medical audit was performed separately in screening-general, screening-treated, and diagnostic group. A total of 43 cases (2.9%) were confirmed as malignancy. Cancer rate among BI-RADS categories was significantly different (p < 0.0001). Among three groups, the cancer rate was significantly different (p < 0.0001) and the highest in diagnostic group (15.8%, 22 of 139). Abnormal interpretation rate, PPV of biopsy performed, cancer detection rate, and rate of early stage cancer, and the size of invasive cancer were significantly different among three groups and the highest in diagnostic group. Regarding cancer characteristics, the proportion of advanced cancer was the highest in diagnostic group. Breast ultrasound based on BI-RADS as an adjunctive to negative mammography can be useful for predicting malignancy in women with dense breast. (orig.)

  11. Study for the design method of multi-agent diagnostic system to improve diagnostic performance for similar abnormality

    International Nuclear Information System (INIS)

    Minowa, Hirotsugu; Gofuku, Akio

    2014-01-01

    Accidents on industrial plants cause large loss on human, economic, social credibility. In recent, studies of diagnostic methods using techniques of machine learning such as support vector machine is expected to detect the occurrence of abnormality in a plant early and correctly. There were reported that these diagnostic machines has high accuracy to diagnose the operating state of industrial plant under mono abnormality occurrence. But the each diagnostic machine on the multi-agent diagnostic system may misdiagnose similar abnormalities as a same abnormality if abnormalities to diagnose increases. That causes that a single diagnostic machine may show higher diagnostic performance than one of multi-agent diagnostic system because decision-making considering with misdiagnosis is difficult. Therefore, we study the design method for multi-agent diagnostic system to diagnose similar abnormality correctly. This method aimed to realize automatic generation of diagnostic system where the generation process and location of diagnostic machines are optimized to diagnose correctly the similar abnormalities which are evaluated from the similarity of process signals by statistical method. This paper explains our design method and reports the result evaluated our method applied to the process data of the fast-breeder reactor Monju

  12. GPs' perspectives on the diagnostic work-up in patients with shoulder pain: a qualitative study.

    Science.gov (United States)

    Ottenheijm, Ramon P G; Hesselmans, Nicolle J J M; Kemper, Anouk; Moser, Albine; de Bie, Rob A; Dinant, Geert-Jan; Cals, Jochen W L

    2014-06-01

    The diagnostic work-up of patients with shoulder pain in general practice is complex. General practitioners' (GPs) guidelines advise a pragmatic diagnostic work-up in which additional imaging has a limited role. However, diagnostic ultrasounds are increasingly ordered by GPs, which seems to reflect complexity in management of shoulder pain. This study aimed to explore GPs' perspectives on the diagnostic work-up of patients with shoulder pain. This study has a qualitative exploratory design with an inductive approach and was carried out in Dutch general practice. The study population consisted of 18 Dutch GPs who were sampled purposefully with a spread in clinical experience and ordering diagnostic ultrasound. Data were gathered by means of semi-structured interviews and analysed following principles of the constant comparative method. Three main categories with subcategories emerged that captured the diagnostic work-up of shoulder pain: variety in diagnostic classifications [(non-)specific diagnosis and interdisciplinary differences], establishing strategies for diagnostic work-up (use of existing tools and motives to deviate from existing tools), and strategies dealing with diagnostic uncertainties (accepting diagnostic uncertainties, diagnostic imaging tests, and interdisciplinary consultation and referral). Despite the availability of evidence-based shoulder guidelines, GPs experience uncertainties during diagnostic work-up and apply different strategies when dealing with these uncertainties. At some point, GPs as well as patients seem to have a need for a specific diagnosis. Currently, there appears to be little agreement if, or in which phase of shoulder pain, diagnostic ultrasound is useful or indicated. © 2014 John Wiley & Sons, Ltd.

  13. Costs and role of ultrasound follow-up of polytrauma patients after initial computed tomography

    International Nuclear Information System (INIS)

    Maurer, M.H.; Winkler, A.; Powerski, M.J.; Elgeti, F.; Huppertz, A.; Roettgen, R.; Marnitz, T.; Wichlas, F.

    2012-01-01

    Purpose: To assess the costs and diagnostic gain of abdominal ultrasound follow-up of polytrauma patients initially examined by whole-body computed tomography (CT). Materials and Methods: A total of 176 patients with suspected multiple trauma (126 men, 50 women; age 43.5 ± 17.4 years) were retrospectively analyzed with regard to supplementary and new findings obtained by ultrasound follow-up compared with the results of exploratory FAST (focused assessment with sonography for trauma) at admission and the findings of whole-body CT. A process model was used to document the staff, materials, and total costs of the ultrasound follow-up examinations. Results: FAST yielded 26 abdominal findings (organ injury and/or free intra-abdominal fluid) in 19 patients, while the abdominal scan of whole-body CT revealed 32 findings in 25 patients. FAST had 81 % sensitivity and 100 % specificity. Follow-up ultrasound examinations revealed new findings in 2 of the 25 patients with abdominal injuries detected with initial CT. In the 151 patients without abdominal injuries in the initial CT scan, ultrasound follow-up did not yield any supplementary or new findings. The total costs of an ultrasound follow-up examination were EUR 28.93. The total costs of all follow-up ultrasound examinations performed in the study population were EUR 5658.23. Conclusion: Follow-up abdominal ultrasound yields only a low overall diagnostic gain in polytrauma patients in whom initial CT fails to detect any abdominal injuries but incurs high personnel expenses for radiological departments. (orig.)

  14. Diagnostic Accuracy of Clinical Examination and Imaging Findings for Identifying Subacromial Pain.

    Science.gov (United States)

    Cadogan, Angela; McNair, Peter J; Laslett, Mark; Hing, Wayne A

    2016-01-01

    The diagnosis of subacromial pathology is limited by the poor accuracy of clinical tests for specific pathologies. The aim of this study was to estimate the diagnostic accuracy of clinical examination and imaging features for identifying subacromial pain (SAP) defined by a positive response to diagnostic injection, and to evaluate the influence of imaging findings on the clinical diagnosis of SAP. In a prospective, diagnostic accuracy design, 208 consecutive patients presenting to their primary healthcare practitioner for the first time with a new episode of shoulder pain were recruited. All participants underwent a standardized clinical examination, shoulder x-ray series and diagnostic ultrasound scan. Results were compared with the response to a diagnostic block of xylocaineTM injected into the SAB under ultrasound guidance using ≥80% post-injection reduction in pain intensity as the positive anaesthetic response (PAR) criterion. Diagnostic accuracy statistics were calculated for combinations of clinical and imaging variables demonstrating the highest likelihood of a PAR. A PAR was reported by 34% of participants. In participants with no loss of passive external rotation, combinations of three clinical variables (anterior shoulder pain, strain injury, absence of symptoms at end-range external rotation (in abduction)) demonstrated 100% specificity for a PAR when all three were positive (LR+ infinity; 95%CI 2.9, infinity). A full-thickness supraspinatus tear on ultrasound increased the likelihood of a PAR irrespective of age (specificity 98% (95%CI 94, 100); LR+ 6.2; 95% CI 1.5, 25.7)). Imaging did not improve the ability to rule-out a PAR. Combinations of clinical examination findings and a full-thickness supraspinatus tear on ultrasound scan can help confirm, but not exclude, the presence of subacromial pain. Other imaging findings were of limited value for diagnosing SAP.

  15. Point-of-care cardiac ultrasound techniques in the physical examination: better at the bedside.

    Science.gov (United States)

    Kimura, Bruce J

    2017-07-01

    The development of hand-carried, battery-powered ultrasound devices has created a new practice in ultrasound diagnostic imaging, called 'point-of-care' ultrasound (POCUS). Capitalising on device portability, POCUS is marked by brief and limited ultrasound imaging performed by the physician at the bedside to increase diagnostic accuracy and expediency. The natural evolution of POCUS techniques in general medicine, particularly with pocket-sized devices, may be in the development of a basic ultrasound examination similar to the use of the binaural stethoscope. This paper will specifically review how POCUS improves the limited sensitivity of the current practice of traditional cardiac physical examination by both cardiologists and non-cardiologists. Signs of left ventricular systolic dysfunction, left atrial enlargement, lung congestion and elevated central venous pressures are often missed by physical techniques but can be easily detected by POCUS and have prognostic and treatment implications. Creating a general set of repetitive imaging skills for these entities for application on all patients during routine examination will standardise and reduce heterogeneity in cardiac bedside ultrasound applications, simplify teaching curricula, enhance learning and recollection, and unify competency thresholds and practice. The addition of POCUS to standard physical examination techniques in cardiovascular medicine will result in an ultrasound-augmented cardiac physical examination that reaffirms the value of bedside diagnosis. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  16. Renal Ultrasound in the Diagnosis of the Non-functioning Kidney

    International Nuclear Information System (INIS)

    Kang, Ik Won; Suh, Jeong Soo

    1982-01-01

    Renal ultrasound is independent of renal function and capable of renal imaging in impaired or dysplastic renal diseases. Authors reviewed renal ultrasonographic findings of 36 cases which showed non-visualization in intravenous pyelography from Feb. 1979 to Sep. 1982 at Seoul National university Hospital. The results are as follows: 1. Causes of non-visualization of the kidney in IVP were unilateral hydronephrosis(18 cases), renal tuberculosis(7), renal failure(6), renal agenesis(3), tumor(1),and pyonephrosis(1) 2. The sonographic findings were diagnostic in all the cases of unilateral hydronephrosis, renal agenesis and renal tumor. 3. The sonographic findings were not diagnostic but suggestive in more than half cases of renal tuberculosis. 4. Renal ultrasound was not helpful in the diagnosis of renal failure, but useful in delineation of renal size and shape

  17. Does the Use of Diagnostic Technology Reduce Fetal Mortality?

    Science.gov (United States)

    Grytten, Jostein; Skau, Irene; Sørensen, Rune; Eskild, Anne

    2018-01-19

    To examine the effect that the introduction of new diagnostic technology in obstetric care has had on fetal death. The Medical Birth Registry of Norway provided detailed medical information for approximately 1.2 million deliveries from 1967 to 1995. Information about diagnostic technology was collected directly from the maternity units, using a questionnaire. The data were analyzed using a hospital fixed-effects regression with fetal mortality as the outcome measure. The key independent variables were the introduction of ultrasound and electronic fetal monitoring at each maternity ward. Hospital-specific trends and risk factors of the mother were included as control variables. The richness of the data allowed us to perform several robustness tests. The introduction of ultrasound caused a significant drop in fetal mortality rate, while the introduction of electronic fetal monitoring had no effect on the rate. In the population as a whole, ultrasound contributed to a reduction in fetal deaths of nearly 20 percent. For post-term deliveries, the reduction was well over 50 percent. The introduction of ultrasound made a major contribution to the decline in fetal mortality at the end of the last century. © Health Research and Educational Trust.

  18. Supervisory Control and Diagnostics System Distributed Operating System

    International Nuclear Information System (INIS)

    McGoldrick, P.R.

    1979-01-01

    This paper contains a description of the Supervisory Control and Diagnostics System (SCDS) Distributed Operating System. The SCDS consists of nine 32-bit minicomputers with shared memory. The system's main purpose is to control a large Mirror Fusion Test Facility

  19. Prediction of trabecular bone qualitative properties using scanning quantitative ultrasound

    Science.gov (United States)

    Qin, Yi-Xian; Lin, Wei; Mittra, Erik; Xia, Yi; Cheng, Jiqi; Judex, Stefan; Rubin, Clint; Müller, Ralph

    2013-11-01

    Microgravity induced bone loss represents a critical health problem in astronauts, particularly occurred in weight-supporting skeleton, which leads to osteopenia and increase of fracture risk. Lack of suitable evaluation modality makes it difficult for monitoring skeletal status in long term space mission and increases potential risk of complication. Such disuse osteopenia and osteoporosis compromise trabecular bone density, and architectural and mechanical properties. While X-ray based imaging would not be practical in space, quantitative ultrasound may provide advantages to characterize bone density and strength through wave propagation in complex trabecular structure. This study used a scanning confocal acoustic diagnostic and navigation system (SCAN) to evaluate trabecular bone quality in 60 cubic trabecular samples harvested from adult sheep. Ultrasound image based SCAN measurements in structural and strength properties were validated by μCT and compressive mechanical testing. This result indicated a moderately strong negative correlations observed between broadband ultrasonic attenuation (BUA) and μCT-determined bone volume fraction (BV/TV, R2=0.53). Strong correlations were observed between ultrasound velocity (UV) and bone's mechanical strength and structural parameters, i.e., bulk Young's modulus (R2=0.67) and BV/TV (R2=0.85). The predictions for bone density and mechanical strength were significantly improved by using a linear combination of both BUA and UV, yielding R2=0.92 for BV/TV and R2=0.71 for bulk Young's modulus. These results imply that quantitative ultrasound can characterize trabecular structural and mechanical properties through measurements of particular ultrasound parameters, and potentially provide an excellent estimation for bone's structural integrity.

  20. THE DIAGNOSTIC VALUE OF CLINICAL EXAMINATION AND ULTRASOUND STUDY OF ENTHESES FOR EARLY DETECTION OF PSORIATIC AND RHEUMATOID ARTHRITIS: REMARC STUDY

    Directory of Open Access Journals (Sweden)

    Tatiana Viktorovna Korotaeva

    2013-01-01

    Full Text Available The diagnosis of enthesitis can help in differentiating early psoriatic arthritis (ePsA from early rheumatoid arthritis (eRA.Objective. To estimate the diagnostic value of detecting enthesitis during clinical examination and ultrasound in ePsA and eRA.Subjects and methods. The trial included 36 patients with ePsA and 33 with eRA. Entheses were evaluated using the Leeds Enthesitis Index (LEI: lateral humeral epicondyle and medial femoral condyle (MFC, Achilles tendon insertion site (ATAP, and plantar fascia (PF point on the right and on the left. Enthesitis (on ultrasound presented with thickening, reduced echo density, and vascularization at Doppler energy imaging. DAS, DAS28, SDAI, CDAI, M±SD, Me [25th, 75th percentile], t-test, Fisher's exact test, χ2test, U test, and Spearman correlation coefficients (R were calculated; the value p < 0.05 was considered statistically significant.Results. Clinical examination revealed enthesitis in 41.6% of the patients with ePsA and in 39.4% of those with eRA (p >0.05. No significant differences were found between ePsA and eRA according to LEI (0.5 [0; 2] and 1 [0; 2] and to LEI+PF (1 [0; 2] and 1 [0; 2], respectively. Enthesitis of MFC and PF was significantly more frequently detected in ePsA than in eRA – 12 (33.3%/2 (6.1% and 10 (27.8%/2 (6.1% patients, respectively. In eRA versus ePsA, enthesitis of MFC was more frequently found (16 (48.4% and 8 (22.2% patients, respectively. Ultrasound revealed no significant differences between the groups in enthesitis. In ePsA, there was a significant correlation between DAS, DAS28, SDAI, CDAI, LEI, and LEI+PF.Conclusion. Enthesis ultrasound cannot differentiate ePsA from eRA. Clinical examination more frequently detects enthesitis in the knee joints in eRA and in the calcaneal region in ePsA.

  1. Electromagnetic-Tracked Biopsy under Ultrasound Guidance: Preliminary Results

    International Nuclear Information System (INIS)

    Hakime, Antoine; Deschamps, Frederic; Marques De Carvalho, Enio Garcia; Barah, Ali; Auperin, Anne; Baere, Thierry De

    2012-01-01

    Purpose: This study was designed to evaluate the accuracy and safety of electromagnetic needle tracking for sonographically guided percutaneous liver biopsies. Methods: We performed 23 consecutive ultrasound-guided liver biopsies for liver nodules with an electromagnetic tracking of the needle. A sensor placed at the tip of a sterile stylet (18G) inserted in a coaxial guiding trocar (16G) used for biopsy was localized in real time relative to the ultrasound imaging plane, thanks to an electromagnetic transmitter and two sensors on the ultrasound probe. This allows for electronic display of the needle tip location and the future needle path overlaid on the real-time ultrasound image. Distance between needle tip position and its electronic display, number of needle punctures, number of needle pull backs for redirection, technical success (needle positioned in the target), diagnostic success (correct histopathology result), procedure time, and complication were evaluated according to lesion sizes, depth and location, operator experience, and “in-plane” or “out-of-plane” needle approach. Results: Electronic display was always within 2 mm from the real position of the needle tip. The technical success rate was 100%. A single needle puncture without repuncture was used in all patients. Pull backs were necessary in six patients (26%) to obtain correct needle placement. The overall diagnostic success rate was 91%. The overall true-positive, true-negative, false-negative, and failure rates of the biopsy were 100% (19/19) 100% (2/2), 0% (0/23), and 9% (2/23). The median total procedure time from the skin puncture to the needle in the target was 30 sec (from 5–60 s). Lesion depth and localizations, operator experience, in-plane or out-of-plane approach did not affect significantly the technical, diagnostic success, or procedure time. Even when the tumor size decreased, the procedure time did not increase. Conclusions: Electromagnetic-tracked biopsy is accurate to

  2. Sampling system for in vivo ultrasound images

    DEFF Research Database (Denmark)

    Jensen, Jorgen Arendt; Mathorne, Jan

    1991-01-01

    Newly developed algorithms for processing medical ultrasound images use the high frequency sampled transducer signal. This paper describes demands imposed on a sampling system suitable for acquiring such data and gives details about a prototype constructed. It acquires full clinical images...... at a sampling frequency of 20 MHz with a resolution of 12 bits. The prototype can be used for real time image processing. An example of a clinical in vivo image is shown and various aspects of the data acquisition process are discussed....

  3. Molecular ultrasound imaging: current status and future directions

    International Nuclear Information System (INIS)

    Deshpande, N.; Needles, A.; Willmann, J.K.

    2010-01-01

    Targeted contrast-enhanced ultrasound (molecular ultrasound) is an emerging imaging strategy that combines ultrasound technology with novel molecularly-targeted ultrasound contrast agents for assessing biological processes at the molecular level. Molecular ultrasound contrast agents are nano- or micro-sized particles that are targeted to specific molecular markers by adding high-affinity binding ligands onto the surface of the particles. Following intravenous administration, these targeted ultrasound contrast agents accumulate at tissue sites overexpressing specific molecular markers, thereby enhancing the ultrasound imaging signal. High spatial and temporal resolution, real-time imaging, non-invasiveness, relatively low costs, lack of ionising irradiation and wide availability of ultrasound systems are advantages compared to other molecular imaging modalities. In this article we review current concepts and future directions of molecular ultrasound imaging, including different classes of molecular ultrasound contrast agents, ongoing technical developments of pre-clinical and clinical ultrasound systems, the potential of molecular ultrasound for imaging different diseases at the molecular level, and the translation of molecular ultrasound into the clinic.

  4. Portable bedside ultrasound: the visual stethoscope of the 21st century

    Directory of Open Access Journals (Sweden)

    Gillman Lawrence M

    2012-03-01

    Full Text Available Abstract Over the past decade technological advances in the realm of ultrasound have allowed what was once a cumbersome and large machine to become essentially hand-held. This coupled with a greater understanding of lung sonography has revolutionized our bedside assessment of patients. Using ultrasound not as a diagnostic test, but instead as a component of the physical exam, may allow it to become the stethoscope of the 21st century.

  5. Laser generated ultrasound sources using polymer nanocomposites for high frequency metrology

    KAUST Repository

    Rajagopal, Srinath; Sainsbury, Toby; Treeby, Bradley; Cox, Ben

    2017-01-01

    Accurate characterisation of ultrasound fields generated by diagnostic and therapeutic transducers is critical for patient safety. This requires hydrophones calibrated to a traceable standard. The existing implementation of the primary standard

  6. Diagnostic system for primary circuits of pressurized-water reactors

    International Nuclear Information System (INIS)

    Liska, J.; Majer, J.

    1983-01-01

    The diagnostic system monitors the reactor, the main circulating pipe, the main circulating pump, the main shut-off valve, the steam generator and the pressurizer. Diagnostic signals are obtained from the sensors designed for operation measurements and from sensors for special diagnostic purposes. The following operations are carried out: detection of dangerous dynamic stress of components, detection of damage to functional surfaces of components, detection of occurrence and propagation of defects in component materials, detection of loose particles and foreign bodies, detection of coolant leakage, detection of coolant boiling in the core and detection of impermissible non-homogeneities of fields of physical quantities in the core. The diagnostic system comprises: monitoring, classification of properly investigated effects, periodical tracing and long-term tracing. The operational diagnostics system developed by the SKODA Concern consists of a vibration monitoring system, a spectral analysis system and a central evaluation system. (M.D.)

  7. Auscultation versus Point-of-care Ultrasound to Determine Endotracheal versus Bronchial Intubation: A Diagnostic Accuracy Study.

    Science.gov (United States)

    Ramsingh, Davinder; Frank, Ethan; Haughton, Robert; Schilling, John; Gimenez, Kimberly M; Banh, Esther; Rinehart, Joseph; Cannesson, Maxime

    2016-05-01

    Unrecognized malposition of the endotracheal tube (ETT) can lead to severe complications in patients under general anesthesia. The focus of this double-blinded randomized study was to assess the accuracy of point-of-care ultrasound in verifying the correct position of the ETT and to compare it with the accuracy of auscultation. Forty-two adult patients requiring general anesthesia with ETT were consented. Patients were randomized to right main bronchus, left main bronchus, or tracheal intubation. After randomization, the ETT was placed via fiber-optic visualization. Next, the location of the ETT was assessed using auscultation by a separate blinded anesthesiologist, followed by an ultrasound performed by a third blinded anesthesiologist. Ultrasound examination included assessment of tracheal dilation via cuff inflation with air and evaluation of pleural lung sliding. Statistical analysis included sensitivity, specificity, positive predictive value, negative predictive value, and interobserver agreement for the ultrasound examination (95% CI). In differentiating tracheal versus bronchial intubations, auscultation showed a sensitivity of 66% (0.39 to 0.87) and a specificity of 59% (0.39 to 0.77), whereas ultrasound showed a sensitivity of 93% (0.66 to 0.99) and specificity of 96% (0.79 to 1). Identification of tracheal versus bronchial intubation was 62% (26 of 42) in the auscultation group and 95% (40 of 42) in the ultrasound group (P = 0.0005) (CI for difference, 0.15 to 0.52), and the McNemar comparison showed statistically significant improvement with ultrasound (P auscultation in determining the location of ETT.

  8. Five-dimensional ultrasound system for soft tissue visualization.

    Science.gov (United States)

    Deshmukh, Nishikant P; Caban, Jesus J; Taylor, Russell H; Hager, Gregory D; Boctor, Emad M

    2015-12-01

    A five-dimensional ultrasound (US) system is proposed as a real-time pipeline involving fusion of 3D B-mode data with the 3D ultrasound elastography (USE) data as well as visualization of these fused data and a real-time update capability over time for each consecutive scan. 3D B-mode data assist in visualizing the anatomy of the target organ, and 3D elastography data adds strain information. We investigate the feasibility of such a system and show that an end-to-end real-time system, from acquisition to visualization, can be developed. We present a system that consists of (a) a real-time 3D elastography algorithm based on a normalized cross-correlation (NCC) computation on a GPU; (b) real-time 3D B-mode acquisition and network transfer; (c) scan conversion of 3D elastography and B-mode volumes (if acquired by 4D wobbler probe); and (d) visualization software that fuses, visualizes, and updates 3D B-mode and 3D elastography data in real time. We achieved a speed improvement of 4.45-fold for the threaded version of the NCC-based 3D USE versus the non-threaded version. The maximum speed was 79 volumes/s for 3D scan conversion. In a phantom, we validated the dimensions of a 2.2-cm-diameter sphere scan-converted to B-mode volume. Also, we validated the 5D US system visualization transfer function and detected 1- and 2-cm spherical objects (phantom lesion). Finally, we applied the system to a phantom consisting of three lesions to delineate the lesions from the surrounding background regions of the phantom. A 5D US system is achievable with real-time performance. We can distinguish between hard and soft areas in a phantom using the transfer functions.

  9. EAMJ The Diagnostic Sep 09.indd

    African Journals Online (AJOL)

    East African Medical Journal Vol. 86 No. 9 September 2009. DIAGNOSTIC VALUES OF DIGITAL RECTAL EXAMINATION, PROSTATE SPECIFIC ANTIGEN AND TRANS-RECTAL. ULTRASOUND IN MEN WITH PROSTATISM. J. P. Manyahi, MD, MMed (Surg), MSc (Urol), Peramiho Hospital, P. O. Box 19, Peramiho.

  10. Actuator-Assisted Calibration of Freehand 3D Ultrasound System.

    Science.gov (United States)

    Koo, Terry K; Silvia, Nathaniel

    2018-01-01

    Freehand three-dimensional (3D) ultrasound has been used independently of other technologies to analyze complex geometries or registered with other imaging modalities to aid surgical and radiotherapy planning. A fundamental requirement for all freehand 3D ultrasound systems is probe calibration. The purpose of this study was to develop an actuator-assisted approach to facilitate freehand 3D ultrasound calibration using point-based phantoms. We modified the mathematical formulation of the calibration problem to eliminate the need of imaging the point targets at different viewing angles and developed an actuator-assisted approach/setup to facilitate quick and consistent collection of point targets spanning the entire image field of view. The actuator-assisted approach was applied to a commonly used cross wire phantom as well as two custom-made point-based phantoms (original and modified), each containing 7 collinear point targets, and compared the results with the traditional freehand cross wire phantom calibration in terms of calibration reproducibility, point reconstruction precision, point reconstruction accuracy, distance reconstruction accuracy, and data acquisition time. Results demonstrated that the actuator-assisted single cross wire phantom calibration significantly improved the calibration reproducibility and offered similar point reconstruction precision, point reconstruction accuracy, distance reconstruction accuracy, and data acquisition time with respect to the freehand cross wire phantom calibration. On the other hand, the actuator-assisted modified "collinear point target" phantom calibration offered similar precision and accuracy when compared to the freehand cross wire phantom calibration, but it reduced the data acquisition time by 57%. It appears that both actuator-assisted cross wire phantom and modified collinear point target phantom calibration approaches are viable options for freehand 3D ultrasound calibration.

  11. Resilient actions in the diagnostic process and system performance.

    Science.gov (United States)

    Smith, Michael W; Davis Giardina, Traber; Murphy, Daniel R; Laxmisan, Archana; Singh, Hardeep

    2013-12-01

    Systemic issues can adversely affect the diagnostic process. Many system-related barriers can be masked by 'resilient' actions of frontline providers (ie, actions supporting the safe delivery of care in the presence of pressures that the system cannot readily adapt to). We explored system barriers and resilient actions of primary care providers (PCPs) in the diagnostic evaluation of cancer. We conducted a secondary data analysis of interviews of PCPs involved in diagnostic evaluation of 29 lung and colorectal cancer cases. Cases covered a range of diagnostic timeliness and were analysed to identify barriers for rapid diagnostic evaluation, and PCPs' actions involving elements of resilience addressing those barriers. We rated these actions according to whether they were usual or extraordinary for typical PCP work. Resilient actions and associated barriers were found in 59% of the cases, in all ranges of timeliness, with 40% involving actions rated as beyond typical. Most of the barriers were related to access to specialty services and coordination with patients. Many of the resilient actions involved using additional communication channels to solicit cooperation from other participants in the diagnostic process. Diagnostic evaluation of cancer involves several resilient actions by PCPs targeted at system deficiencies. PCPs' actions can sometimes mitigate system barriers to diagnosis, and thereby impact the sensitivity of 'downstream' measures (eg, delays) in detecting barriers. While resilient actions might enable providers to mitigate system deficiencies in the short run, they can be resource intensive and potentially unsustainable. They complement, rather than substitute for, structural remedies to improve system performance. Measures to detect and fix system performance issues targeted by these resilient actions could facilitate diagnostic safety.

  12. Implementation of a versatile research data acquisition system using a commercially available medical ultrasound scanner

    DEFF Research Database (Denmark)

    Hemmsen, Martin Christian; Nikolov, Svetoslav Ivanov; Pedersen, Mads Møller

    2012-01-01

    to the clinic. The system consists of a standard PC equipped with a camera link and an ultrasound scanner equipped with a research interface. The ultrasound scanner is an easy-to-use imaging device that is capable of generating high-quality images. In addition to supporting the acquisition of multiple data...

  13. Predicting need for additional CT scan in children with a non-diagnostic ultrasound for appendicitis in the emergency department.

    Science.gov (United States)

    Nishizawa, Takuya; Maeda, Shigenobu; Goldman, Ran D; Hayashi, Hiroyuki

    2018-01-01

    This study aimed to determine which children with suspected appendicitis should be considered for a computerized tomography (CT) scan after a non-diagnostic ultrasound (US) in the Emergency Department (ED). We retrospectively reviewed patients 0-18year old, who presented to the ED with complaints of abdominal pain, during 2011-2015 and while in the hospital had both US and CT. We recorded demographic and clinical data and outcomes, and used univariate and multivariate methods for comparing patients who did and didn't have appendicitis on CT after non-diagnostic US. Multivariate analysis was performed using logistic regression to determine what variables were independently associated with appendicitis. A total of 328 patients were enrolled, 257 with non-diagnostic US (CT: 82 had appendicitis, 175 no-appendicitis). Younger children and those who reported vomiting or had right lower abdominal quadrant (RLQ) tenderness, peritoneal signs or White Blood Cell (WBC) count >10,000 in mm 3 were more likely to have appendicitis on CT. RLQ tenderness (Odds Ratio: 2.84, 95%CI: 1.07-7.53), peritoneal signs (Odds Ratio: 11.37, 95%CI: 5.08-25.47) and WBC count >10,000 in mm 3 (Odds Ratio: 21.88, 95%CI: 7.95-60.21) remained significant after multivariate analysis. Considering CT with 2 or 3 of these predictors would have resulted in sensitivity of 94%, specificity of 67%, positive predictive value of 57% and negative predictive value of 96% for appendicitis. Ordering CT should be considered after non-diagnostic US for appendicitis only when children meet at least 2 predictors of RLQ tenderness, peritoneal signs and WBC>10,000 in mm 3 . Copyright © 2017 Elsevier Inc. All rights reserved.

  14. Microbubbles induce renal hemorrhage when exposed to diagnostic ultrasound in anesthetized rats.

    Science.gov (United States)

    Wible, James H; Galen, Karen P; Wojdyla, Jolette K; Hughes, Michael S; Klibanov, Alexander L; Brandenburger, Gary H

    2002-01-01

    The generation of ultrasound (US) bioeffects using a clinical imaging system is controversial. We tested the hypothesis that the presence of microbubbles in the US field of a medical imager induces biologic effects. Both kidneys of anesthetized rats were insonified for 5 min using a medical imaging system after the administration of microbubbles. One kidney was insonified using a continuous mode (30 Hz) and the opposite kidney was insonified using an intermittent (1 Hz) technique. The microbubbles were exposed to three different transducer frequencies and four transducer output powers. After insonification, the animals were euthanized, the kidneys were removed and their gross appearance scored under "blinded" conditions using a defined scale. After the administration of microbubbles, US imaging of the kidney caused hemorrhage in the renal tissue. The severity and area of hemorrhage increased with an increase in the transducer power and a decrease in the transducer frequency. Intermittent insonification in the presence of microbubbles produced a greater degree of renal hemorrhage than continuous imaging techniques.

  15. Diagnostic Neural Network Systems for the Electronic Circuits

    International Nuclear Information System (INIS)

    Mohamed, A.H.

    2014-01-01

    Neural Networks is one of the most important artificial intelligent approaches for solving the diagnostic processes. This research concerns with uses the neural networks for diagnosis of the electronic circuits. Modern electronic systems contain both the analog and digital circuits. But, diagnosis of the analog circuits suffers from great complexity due to their nonlinearity. To overcome this problem, the proposed system introduces a diagnostic system that uses the neural network to diagnose both the digital and analog circuits. So, it can face the new requirements for the modern electronic systems. A fault dictionary method was implemented in the system. Experimental results are presented on three electronic systems. They are: artificial kidney, wireless network and personal computer systems. The proposed system has improved the performance of the diagnostic systems when applied for these practical cases

  16. Expert system applications in support of system diagnostics and prognostics at EBR-II

    International Nuclear Information System (INIS)

    Lehto, W.K.; Gross, K.C.

    1989-01-01

    Expert systems have been developed to aid in the monitoring and diagnostics of the Experimental Breeder Reactor-II (EBR-II) at the Idaho National Engineering Laboratory (INEL) in Idaho Falls, Idaho. Systems have been developed for failed fuel surveillance and diagnostics and reactor coolant pump monitoring and diagnostics. A third project is being done jointly by ANL-W and EG ampersand G Idaho to develop a transient analysis system to enhance overall plant diagnostic and prognostic capability. The failed fuel surveillance and diagnosis system monitors, processes, and interprets information from nine key plant sensors. It displays to the reactor operator diagnostic information needed to make proper decisions regarding technical specification conformance during reactor operation with failed fuel. 8 refs., 9 figs., 2 tabs

  17. TH-A-207B-01: Basics and Current Implementations of Ultrasound Imaging of Shear Wave Speed and Elasticity

    International Nuclear Information System (INIS)

    Chen, S.

    2016-01-01

    Imaging of tissue elastic properties is a relatively new and powerful approach to one of the oldest and most important diagnostic tools. Imaging of shear wave speed with ultrasound is has been added to most high-end ultrasound systems. Understanding this exciting imaging mode aiding its most effective use in medicine can be a rewarding effort for medical physicists and other medical imaging and treatment professionals. Assuring consistent, quantitative measurements across the many ultrasound systems in a typical imaging department will constitute a major step toward realizing the great potential of this technique and other quantitative imaging. This session will target these two goals with two presentations. A. Basics and Current Implementations of Ultrasound Imaging of Shear Wave Speed and Elasticity - Shigao Chen, Ph.D. Learning objectives-To understand: Introduction: Importance of tissue elasticity measurement Strain vs. shear wave elastography (SWE), beneficial features of SWE The link between shear wave speed and material properties, influence of viscosity Generation of shear waves External vibration (Fibroscan) ultrasound radiation force Point push Supersonic push (Aixplorer) Comb push (GE Logiq E9) Detection of shear waves Motion detection from pulse-echo ultrasound Importance of frame rate for shear wave imaging Plane wave imaging detection How to achieve high effective frame rate using line-by-line scanners Shear wave speed calculation Time to peak Random sample consensus (RANSAC) Cross correlation Sources of bias and variation in SWE Tissue viscosity Transducer compression or internal pressure of organ Reflection of shear waves at boundaries B. Elasticity Imaging System Biomarker Qualification and User Testing of Systems – Brian Garra, M.D. Learning objectives-To understand: Goals Review the need for quantitative medical imaging Provide examples of quantitative imaging biomarkers Acquaint the participant with the purpose of the RSNA Quantitative Imaging

  18. TH-A-207B-01: Basics and Current Implementations of Ultrasound Imaging of Shear Wave Speed and Elasticity

    Energy Technology Data Exchange (ETDEWEB)

    Chen, S. [Mayo Clinic (United States)

    2016-06-15

    Imaging of tissue elastic properties is a relatively new and powerful approach to one of the oldest and most important diagnostic tools. Imaging of shear wave speed with ultrasound is has been added to most high-end ultrasound systems. Understanding this exciting imaging mode aiding its most effective use in medicine can be a rewarding effort for medical physicists and other medical imaging and treatment professionals. Assuring consistent, quantitative measurements across the many ultrasound systems in a typical imaging department will constitute a major step toward realizing the great potential of this technique and other quantitative imaging. This session will target these two goals with two presentations. A. Basics and Current Implementations of Ultrasound Imaging of Shear Wave Speed and Elasticity - Shigao Chen, Ph.D. Learning objectives-To understand: Introduction: Importance of tissue elasticity measurement Strain vs. shear wave elastography (SWE), beneficial features of SWE The link between shear wave speed and material properties, influence of viscosity Generation of shear waves External vibration (Fibroscan) ultrasound radiation force Point push Supersonic push (Aixplorer) Comb push (GE Logiq E9) Detection of shear waves Motion detection from pulse-echo ultrasound Importance of frame rate for shear wave imaging Plane wave imaging detection How to achieve high effective frame rate using line-by-line scanners Shear wave speed calculation Time to peak Random sample consensus (RANSAC) Cross correlation Sources of bias and variation in SWE Tissue viscosity Transducer compression or internal pressure of organ Reflection of shear waves at boundaries B. Elasticity Imaging System Biomarker Qualification and User Testing of Systems – Brian Garra, M.D. Learning objectives-To understand: Goals Review the need for quantitative medical imaging Provide examples of quantitative imaging biomarkers Acquaint the participant with the purpose of the RSNA Quantitative Imaging

  19. Bone Composition Diagnostics: Photoacoustics Versus Ultrasound

    Science.gov (United States)

    Yang, Lifeng; Lashkari, Bahman; Mandelis, Andreas; Tan, Joel W. Y.

    2015-06-01

    Ultrasound (US) backscatter from bones depends on the mechanical properties and the microstructure of the interrogated bone. On the other hand, photoacoustics (PA) is sensitive to optical properties of tissue and can detect composition variation. Therefore, PA can provide complementary information about bone health and integrity. In this work, a comparative study of US backscattering and PA back-propagating signals from animal trabecular bones was performed. Both methods were applied using a linear frequency modulation chirp and matched filtering. A 2.2 MHz ultrasonic transducer was employed to detect both signals. The use of the frequency domain facilitates spectral analysis. The variation of signals shows that in addition to sensitivity to mineral changes, PA exhibits sensitivity to changes in the organic part of the bone. It is, therefore, concluded that the combination of both modalities can provide complementary detailed information on bone health than either method separately. In addition, comparison of PA and US depthwise images shows the higher penetration of US. Surface scan images exhibit very weak correlation between US and PA which could be caused by the different signal generation origins in mechanical versus optical properties, respectively.

  20. Field: A Program for Simulating Ultrasound Systems

    DEFF Research Database (Denmark)

    Jensen, Jørgen Arendt

    1997-01-01

    A program for the simulation of ultrasound systems is presented.It is based on the Tupholme-Stepanishen method, and is fastbecause of the use of a far-field approximation. Any kind oftransducer geometry and excitation can be simulated, and bothpulse-echo and continuous wave fields can be calculated...... for bothtransmit and pulse-echo. Dynamic apodization and focusing arehandled through time lines, and different focusingschemes can be simulated. The versatility of the program isensured by interfacing it to Matlab. All routines are calleddirectly from Matlab, and all Matlab features can be used. Thismakes...

  1. Assessment of portal venous system patency in the liver transplant candidate: A prospective study comparing ultrasound, microbubble-enhanced colour Doppler ultrasound, with arteriography and surgery

    International Nuclear Information System (INIS)

    Marshall, M.M.; Beese, R.C.; Muiesan, P.; Sarma, D.I.; O'Grady, J.; Sidhu, P.S.

    2002-01-01

    AIM: To determine the role of microbubble-enhanced colour Doppler ultrasound (CDUS) in assessing portal venous patency prior to liver transplantation. MATERIALS AND METHODS: Over a 2-year period, all patients with chronic liver disease undergoing routine pre-transplant CDUS examination in whom the portal venous system was inadequately demonstrated were recruited to the study. CDUS was performed in 368 patients and 33 patients (9%) were recruited. A repeat CDUS examination following an intravenous bolus injection of the microbubble contrast agent Levovist[reg] (Schering Healthcare AG, Berlin, Germany) was performed. Diagnostic confidence was recorded on a free linear analogue scale for both examinations. Findings were compared with indirect portography and surgery. RESULTS: Of the 33 patients with sub-optimal baseline examinations, improvement in portal vein visualization was achieved in 31 patients (94%). Median diagnostic confidence increased from 50% (interquartile range 30-60) to 90% (interquartile range 75-98) (P < 0.001) following administration of Levovist[reg]. Overall accuracy of portal vein assessment using microbubble-enhanced CDUS in 15 patients in whom a definitive diagnosis was made within 2 months was 87%. CONCLUSION: Microbubble-enhanced CDUS is a simple, inexpensive adjunct to standard pre liver transplant screening of the portal vein. It is particularly helpful in patients with end-stage cirrhosis who are at high risk of portal vein thrombosis and in whom the conventional examination is sub-optimal.Marshall, M.M. et al. (2002)

  2. A novel fusion imaging system for endoscopic ultrasound

    DEFF Research Database (Denmark)

    Gruionu, Lucian Gheorghe; Saftoiu, Adrian; Gruionu, Gabriel

    2016-01-01

    BACKGROUND AND OBJECTIVE: Navigation of a flexible endoscopic ultrasound (EUS) probe inside the gastrointestinal (GI) tract is problematic due to the small window size and complex anatomy. The goal of the present study was to test the feasibility of a novel fusion imaging (FI) system which uses...... time was 24.6 ± 6.6 min, while the time to reach the clinical target was 8.7 ± 4.2 min. CONCLUSIONS: The FI system is feasible for clinical use, and can reduce the learning curve for EUS procedures and improve navigation and targeting in difficult anatomic locations....

  3. Knowledge acquisition for nuclear power plant unit diagnostic system

    International Nuclear Information System (INIS)

    Li Xiaodong; Xi Shuren

    2003-01-01

    The process of acquiring knowledge and building a knowledge base is critical to realize fault diagnostic system at unit level in a nuclear power plant. It directly determines whether the diagnostic system can be applied eventually in a commercial plant. A means to acquire knowledge and its procedures was presented in this paper for fault diagnostic system in a nuclear power plant. The work can be carried out step by step and it is feasible in a commercial nuclear power plant. The knowledge base of the fault diagnostic system for a nuclear power plant can be built after the staff finish the tasks according to the framework presented in this paper

  4. Validation of the fifth edition BI-RADS ultrasound lexicon with comparison of fourth and fifth edition diagnostic performance using video clips

    International Nuclear Information System (INIS)

    Yoon, Jung Hyun; Kim, Min Jung; Lee, Hye Sun; Kim, Sung Hun; Youk, Ji Hyun; Jeong, Sun Hye; Kim, You Me

    2016-01-01

    The aim of this study was to evaluate the positive predictive value (PPV) and the diagnostic performance of the ultrasonographic descriptors in the fifth edition of BI-RADS, comparing with the fourth edition using video clips. From September 2013 to July 2014, 80 breast masses in 74 women (mean age, 47.5±10.7 years) from five institutions of the Korean Society of Breast Imaging were included. Two radiologists individually reviewed the static and video images and analyzed the images according to the fourth and fifth edition of BI-RADS. The PPV of each descriptor was calculated and diagnostic performances between the fourth and fifth editions were compared. Of the 80 breast masses, 51 (63.8%) were benign and 29 (36.2%) were malignant. Suspicious ultrasonographic features such as irregular shape, non-parallel orientation, angular or spiculated margins, and combined posterior features showed higher PPV in both editions (all P<0.05). No significant differences were found in the diagnostic performances between the two editions (all P>0.05). The area under the receiver operating characteristics curve was higher in the fourth edition (0.708 to 0.690), without significance (P=0.416). The fifth edition of the BI-RADS ultrasound lexicon showed comparable performance to the fourth edition and can be useful in the differential diagnosis of breast masses using ultrasonography

  5. Diagnostic accuracy of magnetic resonance, computed tomography and contrast enhanced ultrasound in radiological multimodality assessment of peribiliary liver metastases.

    Directory of Open Access Journals (Sweden)

    Vincenza Granata

    Full Text Available We compared diagnostic performance of Magnetic Resonance (MR, Computed Tomography (CT and Ultrasound (US with (CEUS and without contrast medium to identify peribiliary metastasis.We identified 35 subjects with histological proven peribiliary metastases who underwent CEUS, CT and MR study. Four radiologists evaluated the presence of peribiliary lesions, using a 4-point confidence scale. Echogenicity, density and T1-Weigthed (T1-W, T2-W and Diffusion Weighted Imaging (DWI signal intensity as well as the enhancement pattern during contrast studies on CEUS, CT and MR so as hepatobiliary-phase on MRI was assessed.All lesions were detected by MR. CT detected 8 lesions, while US/CEUS detected one lesion. According to the site of the lesion, respect to the bile duct and hepatic parenchyma: 19 (54.3% were periductal, 15 (42.8% were intra-periductal and 1 (2.8% was periductal-intrahepatic. According to the confidence scale MRI had the best diagnostic performance to assess the lesion. CT obtained lower diagnostic performance. There was no significant difference in MR signal intensity and contrast enhancement among all metastases (p>0.05. There was no significant difference in CT density and contrast enhancement among all metastases (p>0.05.MRI is the method of choice for biliary tract tumors but it does not allow a correct differential diagnosis among different histological types of metastasis. The presence of biliary tree dilatation without hepatic lesions on CT and US/CEUS study may be an indirect sign of peribiliary metastases and for this reason the patient should be evaluated by MRI.

  6. Laboratory Information Systems in Molecular Diagnostics: Why Molecular Diagnostics Data are Different.

    Science.gov (United States)

    Lee, Roy E; Henricks, Walter H; Sirintrapun, Sahussapont J

    2016-03-01

    Molecular diagnostic testing presents new challenges to information management that are yet to be sufficiently addressed by currently available information systems for the molecular laboratory. These challenges relate to unique aspects of molecular genetic testing: molecular test ordering, informed consent issues, diverse specimen types that encompass the full breadth of specimens handled by traditional anatomic and clinical pathology information systems, data structures and data elements specific to molecular testing, varied testing workflows and protocols, diverse instrument outputs, unique needs and requirements of molecular test reporting, and nuances related to the dissemination of molecular pathology test reports. By satisfactorily addressing these needs in molecular test data management, a laboratory information system designed for the unique needs of molecular diagnostics presents a compelling reason to migrate away from the current paper and spreadsheet information management that many molecular laboratories currently use. This paper reviews the issues and challenges of information management in the molecular diagnostics laboratory.

  7. The opinion and experiences of Dutch orthopedic surgeons and radiologists about diagnostic musculoskeletal ultrasound imaging in primary care: a survey.

    Science.gov (United States)

    Scholten-Peeters, Gwendolijne G M; Franken, Nicole; Beumer, Annechien; Verhagen, Arianne P

    2014-04-01

    The use of diagnostic musculoskeletal ultrasound (DMUS) in primary health care has increased in the recent years. Nevertheless, there are hardly any data concerning the reliability, accuracy and treatment consequences of DMUS used by physical therapists or general practitioners. Moreover, there are no papers published about how orthopedic surgeons or radiologists deal with the results of DMUS performed in primary care. Therefore, our aim is to evaluate the opinion, possible advantages or disadvantages and experiences of Dutch orthopedic surgeons and radiologists about DMUS in primary care. A cross-sectional survey in which respondents completed a self-developed questionnaire to determine their opinion, experiences, advantages, disadvantages of performing DMUS in primary care. Questionnaires were sent to 838 Dutch orthopedic surgeons and radiologists of which 213 were returned (response rate 25.4%). Our respondents saw no additional value for health care for diagnostic DMUS in primary care. DMUSs were generally repeated in secondary care. They perceived more disadvantages than advantages of performing DMUS in primary care. Mentioned disadvantages were: 'false positive results' (71.4%), 'lack of experience' (70%), 'insufficient education' (69.5%), not able to relate the outcomes of DMUS with other forms of diagnostic imaging' (65.7%), and 'false negative results' (65.3%). Radiologists and orthopedic surgeons sampled in the Netherlands show low trust in DMUS knowledge of physical therapists and general practitioners. The results should be interpreted with caution because of the small response rate and the lack of representativeness to other countries. Published by Elsevier Ltd.

  8. HIFU Monitoring and Control with Dual-Mode Ultrasound Arrays

    Science.gov (United States)

    Casper, Andrew Jacob

    The biological effects of high-intensity focused ultrasound (HIFU) have been known and studied for decades. HIFU has been shown capable of treating a wide variety of diseases and disorders. However, despite its demonstrated potential, HIFU has been slow to gain clinical acceptance. This is due, in part, to the difficulty associated with robustly monitoring and controlling the delivery of the HIFU energy. The non-invasive nature of the surgery makes the assessment of treatment progression difficult, leading to long treatment times and a significant risk of under treatment. This thesis research develops new techniques and systems for robustly monitoring HIFU therapies for the safe and efficacious delivery of the intended treatment. Systems and algorithms were developed for the two most common modes of HIFU delivery systems: single-element and phased array applicators. Delivering HIFU with a single element transducer is a widely used technique in HIFU therapies. The simplicity of a single element offers many benefits in terms of cost and overall system complexity. Typical monitoring schemes rely on an external device (e.g. diagnostic ultrasound or MRI) to assess the progression of therapy. The research presented in this thesis explores using the same element to both deliver and monitor the HIFU therapy. The use of a dual-mode ultrasound transducer (DMUT) required the development of an FPGA based single-channel arbitrary waveform generator and high-speed data acquisition unit. Data collected from initial uncontrolled ablations led to the development of monitoring and control algorithms which were implemented directly on the FPGA. Close integration between the data acquisition and arbitrary waveform units allowed for fast, low latency control over the ablation process. Results are presented that demonstrate control of HIFU therapies over a broad range of intensities and in multiple in vitro tissues. The second area of investigation expands the DMUT research to an

  9. Ultrasound assessment of selected peripheral nerve pathologies. Part III: Injuries and postoperative evaluation

    Directory of Open Access Journals (Sweden)

    Berta Kowalska

    2013-03-01

    Full Text Available The previous articles of the series devoted to ultrasound diagnostics of peripheral nerves concerned the most common nerve pathologies, i.e. entrapment neuropathies. The aim of the last part of the series is to present ultrasound possibilities in the postoperative control of the peripheral nerves as well as in the diagnostics of the second most common neuropathies of peripheral nerves, i.e. posttraumatic lesions. Early diagnostics of posttraumatic changes is of fundamental importance for the course of treatment and its long-term effects. It aids surgeons in making treatment decisions (whether surgical or conservative. When surgical treatment is necessary, the surgeon, based on US findings, is able to plan a given type of operative method. In certain cases, may even abandon the corrective or reconstructive surgery of the nerve trunk (when there are extensive defects of the nerve trunks and instead, proceed with muscle transfers. Medical literature proposes a range of divisions of the kinds of peripheral nerve injuries depending on, among others, the mechanism or degree of damage. However, the most important issue in the surgeon-diagnostician communication is a detailed description of stumps of the nerve trunks, their distance and location. In the postoperative period, ultrasound is used for monitoring the operative or conservative treatment effects including the determination of the causes of a persistent or recurrent neuropathy. It facilitates decision-making concerning a repeated surgical procedure or assuming a wait-and-see attitude. It is a difficult task for a diagnostician and it requires experience, close cooperation with a clinician and knowledge concerning surgical techniques. Apart from a static assessment, a dynamic assessment of possible adhesions constitutes a crucial element of postoperative examination. This feature distinguishes ultrasound scanning from other methods used in the diagnostics of peripheral neuropathies.

  10. Ultrasound-guided percutaneous core needle biopsy of splenic lesions

    Energy Technology Data Exchange (ETDEWEB)

    Park, SangIk; Shin, Yong Moon; Won, Hyung Jin; Kim, Pyo Nyun; Lee, Moon Gyu [Dept. of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center, Seoul (Korea, Republic of)

    2017-05-15

    To evaluate the safety and efficacy of ultrasound-guided percutaneous core needle biopsy of splenic lesions. This retrospective study included 30 patients who underwent percutaneous core needle biopsy of their splenic lesions using 18- or 20-gauge needles between January 2001 and July 2016 in a single tertiary care center. The characteristics of the splenic lesions were determined by reviewing the ultrasound and computed tomography examinations. Acquisition rate and diagnostic accuracy were calculated, using pathologic results of the splenectomy specimen, clinical course and/or imaging follow-up as a reference standard. Post-procedure complications were identified from electronic medical records, laboratory findings and computed tomography images. Seventy-three specimens were obtained from the 30 patients and splenectomy was performed in 2 patients. Twenty-nine of the 30 patients had focal splenic lesions, while the remaining patient had homogeneous splenomegaly. Acquisition rate and diagnostic accuracy were 80.0% (24/30) and 76.7% (23/30), respectively. Perisplenic hemorrhage without hemodynamic instability developed in one patient. Ultrasound-guided percutaneous core needle biopsy of splenic lesions is a safe method for achieving a histopathologic diagnosis and can be considered as an alternative to splenectomy in patients with a high risk of splenectomy-related complications.

  11. Ultrasound-guided percutaneous core needle biopsy of splenic lesions

    International Nuclear Information System (INIS)

    Park, SangIk; Shin, Yong Moon; Won, Hyung Jin; Kim, Pyo Nyun; Lee, Moon Gyu

    2017-01-01

    To evaluate the safety and efficacy of ultrasound-guided percutaneous core needle biopsy of splenic lesions. This retrospective study included 30 patients who underwent percutaneous core needle biopsy of their splenic lesions using 18- or 20-gauge needles between January 2001 and July 2016 in a single tertiary care center. The characteristics of the splenic lesions were determined by reviewing the ultrasound and computed tomography examinations. Acquisition rate and diagnostic accuracy were calculated, using pathologic results of the splenectomy specimen, clinical course and/or imaging follow-up as a reference standard. Post-procedure complications were identified from electronic medical records, laboratory findings and computed tomography images. Seventy-three specimens were obtained from the 30 patients and splenectomy was performed in 2 patients. Twenty-nine of the 30 patients had focal splenic lesions, while the remaining patient had homogeneous splenomegaly. Acquisition rate and diagnostic accuracy were 80.0% (24/30) and 76.7% (23/30), respectively. Perisplenic hemorrhage without hemodynamic instability developed in one patient. Ultrasound-guided percutaneous core needle biopsy of splenic lesions is a safe method for achieving a histopathologic diagnosis and can be considered as an alternative to splenectomy in patients with a high risk of splenectomy-related complications

  12. BWR recirculation pump diagnostic expert system

    International Nuclear Information System (INIS)

    Chiang, S.C.; Morimoto, C.N.; Torres, M.R.

    2004-01-01

    At General Electric (GE), an on-line expert system to support maintenance decisions for BWR recirculation pumps for nuclear power plants has been developed. This diagnostic expert system is an interactive on-line system that furnishes diagnostic information concerning BWR recirculation pump operational problems. It effectively provides the recirculation pump diagnostic expertise in the plant control room continuously 24 hours a day. The expert system is interfaced to an on-line monitoring system, which uses existing plant sensors to acquire non-safety related data in real time. The expert system correlates and evaluates process data and vibration data by applying expert rules to determine the condition of a BWR recirculation pump system by applying knowledge based rules. Any diagnosis will be automatically displayed, indicating which pump may have a problem, the category of the problem, and the degree of concern expressed by the validity index and color hierarchy. The rules incorporate the expert knowledge from various technical sources such as plant experience, engineering principles, and published reports. These rules are installed in IF-THEN formats and the resulting truth values are also expressed in fuzzy terms and a certainty factor called a validity index. This GE Recirculation Pump Expert System uses industry-standard software, hardware, and network access to provide flexible interfaces with other possible data acquisition systems. Gensym G2 Real-Time Expert System is used for the expert shell and provides the graphical user interface, knowledge base, and inference engine capabilities. (author)

  13. Confirmation of Essure placement using transvaginal ultrasound.

    Science.gov (United States)

    Veersema, Sebastiaan; Vleugels, Michel; Koks, Caroline; Thurkow, Andreas; van der Vaart, Huub; Brölmann, Hans

    2011-01-01

    To evaluate the protocol for confirmation of satisfactory Essure placement using transvaginal ultrasound. Prospective multicenter cohort study (Canadian Task Force classification II-2). Outpatient departments of 4 teaching hospitals in the Netherlands. Eleven hundred forty-five women who underwent hysteroscopic sterilization using the Essure device between March 2005 and December 2007. Transvaginal ultrasound examination 12 weeks after uncomplicated successful bilateral placement or as indicated according to the transvaginal ultrasound protocol after 4 weeks, and hysterosalpingography (HSG) at 12 weeks to confirm correct placement of the device after 3 months. The rate of successful placement was 88.4% initially. In 164 women (15%), successful placement was confirmed at HSG according the protocol. In 9 patients (0.84%), incorrect position of the device was observed at HSG. The cumulative pregnancy rate after 18 months was 3.85 per thousand women. Transvaginal ultrasound should be the first diagnostic test used to confirm the adequacy of hysteroscopic Essure sterilization because it is minimally invasive, averts ionizing radiation, and does not decrease the effectiveness of the Essure procedure. Copyright © 2011 AAGL. Published by Elsevier Inc. All rights reserved.

  14. Combined Use of Ultrasound Elastography and B-Mode Sonography for Differentiation of Benign and Malignant Circumscribed Breast Masses.

    Science.gov (United States)

    Kim, Soo-Yeon; Park, Jeong Seon; Koo, Hye Ryoung

    2015-11-01

    To evaluate the diagnostic performance of combined B-mode sonography and ultrasound elastography for differentiation between benign and malignant breast masses with circumscribed margins. We analyzed 109 pathologically proven circumscribed breast masses. Two radiologists retrospectively reviewed B-mode sonograms and elastograms in consensus. Based on the American College of Radiology Breast Imaging Reporting and Data System, we determined categories of the masses on B-mode sonography. Elastographic scores were assessed by a 3-point scale (negative, 0; equivocal, 1; and positive, 2). When the elastographic score for a lesion was 0 or 2, we downgraded or upgraded the B-mode category, respectively; thus, the reclassified Breast Imaging Reporting and Data System category was defined as the "reclassification category." Mean category values for benign and malignant lesions were compared by a Student t test. The diagnostic performance of B-mode, elastographic, and reclassification assessments was compared by receiver operating characteristic curve analysis. The mean B-mode category (2.5 versus 1.7), elastographic score (1.7 versus 0.8), and reclassification category (3.2 versus 1.6) were significantly higher in malignant than benign lesions (P benign and malignant circumscribed breast masses, combined use of B-mode sonography and elastography could provide a better diagnostic performance than B-mode sonography alone. © 2015 by the American Institute of Ultrasound in Medicine.

  15. PLGA Nanoparticles for Ultrasound-Mediated Gene Delivery to Solid Tumors

    Directory of Open Access Journals (Sweden)

    Marxa Figueiredo

    2012-01-01

    Full Text Available This paper focuses on novel approaches in the field of nanotechnology-based carriers utilizing ultrasound stimuli as a means to spatially target gene delivery in vivo, using nanoparticles made with either poly(lactic-co-glycolic acid (PLGA or other polymers. We specifically discuss the potential for gene delivery by particles that are echogenic (amenable to destruction by ultrasound composed either of polymers (PLGA, polystyrene or other contrast agent materials (Optison, SonoVue microbubbles. The use of ultrasound is an efficient tool to further enhance gene delivery by PLGA or other echogenic particles in vivo. Echogenic PLGA nanoparticles are an attractive strategy for ultrasound-mediated gene delivery since this polymer is currently approved by the US Food and Drug Administration for drug delivery and diagnostics in cancer, cardiovascular disease, and also other applications such as vaccines and tissue engineering. This paper will review recent successes and the potential of applying PLGA nanoparticles for gene delivery, which include (a echogenic PLGA used with ultrasound to enhance local gene delivery in tumors or muscle and (b PLGA nanoparticles currently under development, which could benefit in the future from ultrasound-enhanced tumor targeted gene delivery.

  16. Applications of ultrasound in dentistry.

    Science.gov (United States)

    Walmsley, A D

    1988-01-01

    An ultrasonic descaler working at kHz frequencies is used in dentistry to remove attached deposits from the teeth. Such devices offer many advantages over conventional hand instruments by reducing both the work and time involved in the clinical descaling process. Although it is a recognised clinical instrument, there has been little attempt to standardise its acoustic power output. A parameter which may characterise adequately the acoustic emission from these instruments is the displacement amplitude of the probe tip. Modification of the ultrasonic descaler generator has led to the further use of the instrument in other dental areas. Diagnostic applications of MHz ultrasound is limited by the structure and arrangement of the dental tissues. Therapeutic ultrasound has been used to treat a variety of dentally related ailments, and ultrasonic cleaning baths are used to clean both dental instruments and materials.

  17. TFTR diagnostic control and data acquisition system

    International Nuclear Information System (INIS)

    Sauthoff, N.R.; Daniels, R.E.; PPL Computer Division

    1985-01-01

    General computerized control and data-handling support for TFTR diagnostics is presented within the context of the Central Instrumentation, Control and Data Acquisition (CICADA) System. Procedures, hardware, the interactive man--machine interface, event-driven task scheduling, system-wide arming and data acquisition, and a hierarchical data base of raw data and results are described. Similarities in data structures involved in control, monitoring, and data acquisition afford a simplification of the system functions, based on ''groups'' of devices. Emphases and optimizations appropriate for fusion diagnostic system designs are provided. An off-line data reduction computer system is under development

  18. A recommender system for medical imaging diagnostic.

    Science.gov (United States)

    Monteiro, Eriksson; Valente, Frederico; Costa, Carlos; Oliveira, José Luís

    2015-01-01

    The large volume of data captured daily in healthcare institutions is opening new and great perspectives about the best ways to use it towards improving clinical practice. In this paper we present a context-based recommender system to support medical imaging diagnostic. The system relies on data mining and context-based retrieval techniques to automatically lookup for relevant information that may help physicians in the diagnostic decision.

  19. SU-G-JeP3-08: Robotic System for Ultrasound Tracking in Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Kuhlemann, I [University of Luebeck, Luebeck (Germany); Graduate School for Computing in Medicine and Life Sciences, University of Luebeck (Germany); Jauer, P; Schweikard, A; Ernst, F [University of Luebeck, Luebeck (Germany)

    2016-06-15

    Purpose: For safe and accurate real-time tracking of tumors for IGRT using 4D ultrasound, it is necessary to make use of novel, high-end force-sensitive lightweight robots designed for human-machine interaction. Such a robot will be integrated into an existing robotized ultrasound system for non-invasive 4D live tracking, using a newly developed real-time control and communication framework. Methods: The new KUKA LWR iiwa robot is used for robotized ultrasound real-time tumor tracking. Besides more precise probe contact pressure detection, this robot provides an additional 7th link, enhancing the dexterity of the kinematic and the mounted transducer. Several integrated, certified safety features create a safe environment for the patients during treatment. However, to remotely control the robot for the ultrasound application, a real-time control and communication framework has to be developed. Based on a client/server concept, client-side control commands are received and processed by a central server unit and are implemented by a client module running directly on the robot’s controller. Several special functionalities for robotized ultrasound applications are integrated and the robot can now be used for real-time control of the image quality by adjusting the transducer position, and contact pressure. The framework was evaluated looking at overall real-time capability for communication and processing of three different standard commands. Results: Due to inherent, certified safety modules, the new robot ensures a safe environment for patients during tumor tracking. Furthermore, the developed framework shows overall real-time capability with a maximum average latency of 3.6 ms (Minimum 2.5 ms; 5000 trials). Conclusion: The novel KUKA LBR iiwa robot will advance the current robotized ultrasound tracking system with important features. With the developed framework, it is now possible to remotely control this robot and use it for robotized ultrasound tracking

  20. SU-G-JeP3-08: Robotic System for Ultrasound Tracking in Radiation Therapy

    International Nuclear Information System (INIS)

    Kuhlemann, I; Jauer, P; Schweikard, A; Ernst, F

    2016-01-01

    Purpose: For safe and accurate real-time tracking of tumors for IGRT using 4D ultrasound, it is necessary to make use of novel, high-end force-sensitive lightweight robots designed for human-machine interaction. Such a robot will be integrated into an existing robotized ultrasound system for non-invasive 4D live tracking, using a newly developed real-time control and communication framework. Methods: The new KUKA LWR iiwa robot is used for robotized ultrasound real-time tumor tracking. Besides more precise probe contact pressure detection, this robot provides an additional 7th link, enhancing the dexterity of the kinematic and the mounted transducer. Several integrated, certified safety features create a safe environment for the patients during treatment. However, to remotely control the robot for the ultrasound application, a real-time control and communication framework has to be developed. Based on a client/server concept, client-side control commands are received and processed by a central server unit and are implemented by a client module running directly on the robot’s controller. Several special functionalities for robotized ultrasound applications are integrated and the robot can now be used for real-time control of the image quality by adjusting the transducer position, and contact pressure. The framework was evaluated looking at overall real-time capability for communication and processing of three different standard commands. Results: Due to inherent, certified safety modules, the new robot ensures a safe environment for patients during tumor tracking. Furthermore, the developed framework shows overall real-time capability with a maximum average latency of 3.6 ms (Minimum 2.5 ms; 5000 trials). Conclusion: The novel KUKA LBR iiwa robot will advance the current robotized ultrasound tracking system with important features. With the developed framework, it is now possible to remotely control this robot and use it for robotized ultrasound tracking

  1. Bipolar-power-transistor-based limiter for high frequency ultrasound imaging systems.

    Science.gov (United States)

    Choi, Hojong; Yang, Hao-Chung; Shung, K Kirk

    2014-03-01

    High performance limiters are described in this paper for applications in high frequency ultrasound imaging systems. Limiters protect the ultrasound receiver from the high voltage (HV) spikes produced by the transmitter. We present a new bipolar power transistor (BPT) configuration and compare its design and performance to a diode limiter used in traditional ultrasound research and one commercially available limiter. Limiter performance depends greatly on the insertion loss (IL), total harmonic distortion (THD) and response time (RT), each of which will be evaluated in all the limiters. The results indicated that, compared with commercial limiter, BPT-based limiter had less IL (-7.7 dB), THD (-74.6 dB) and lower RT (43 ns) at 100 MHz. To evaluate the capability of these limiters, they were connected to a 100 MHz single element transducer and a two-way pulse-echo test was performed. It was found that the -6 dB bandwidth and sensitivity of the transducer using BPT-based limiter were better than those of the commercial limiter by 22% and 140%, respectively. Compared to the commercial limiter, BPT-based limiter is shown to be capable of minimizing signal attenuation, RT and THD at high frequencies and is thus suited for high frequency ultrasound applications. Copyright © 2013 Elsevier B.V. All rights reserved.

  2. Practical recommendations for performing ultrasound scanning in the urological and andrological fields

    Directory of Open Access Journals (Sweden)

    Pasquale Martino

    2014-03-01

    Full Text Available Aim: US scanning has been defined as the urologist’s stethoscope. These recommendations have been drawn up with the aim of ensuring minimum standards of excellence for ultrasound imaging in urological and andrological practice. A series of essential recommendations are made, to be followed during ultrasound investigations in kidney, prostate, bladder, scrotal and penile diseases. Methods: Members of the Imaging Working Group of the Italian Society of Urology (SIU in collaboration with the Italian Society of Ultrasound in Urology, Andrology and Nephrology (SIEUN identified expert Urologists, Andrologists, Nephrologists and Radiologists. The recommendations are based on review of the literature, previously published recommendations, books and the opinions of the experts. The final document was reviewed by national experts, including members of the Italian Society of Radiology. Results: Recommendations are listed in 5 chapters, focused on: kidney, bladder, prostate and seminal vesicles, scrotum and testis, penis, including penile echo-doppler. In each chapter clear definitions are made of: indications, technological standards of the devices, the method of performance of the investigation. The findings to be reported are described and discussed, and examples of final reports for each organ are included. In the tables, the ultrasound features of the principal male uro-genital diseases are summarized. Diagnostic accuracy and second level investigations are considered. Conclusions: Ultrasound is an integral part of the diagnosis and follow-up of diseases of the urinary system and male genitals in patients of all ages, in both the hospital and outpatient setting. These recommendations are dedicated to enhancing communication and evidence-based medicine in an inter- and multi-disciplinary approach. The ability to perform and interpret ultrasound imaging correctly has become an integral part of clinical practice in uro-andrology, but intra and inter

  3. Practical recommendations for performing ultrasound scanning in the urological and andrological fields.

    Science.gov (United States)

    Martino, Pasquale; Galosi, Andrea Benedetto; Bitelli, Marco; Consonni, Paolo; Fiorini, Fulvio; Granata, Antonio; Gunelli, Roberta; Liguori, Giovanni; Palazzo, Silvano; Pavan, Nicola; Scattoni, Vincenzo; Virgili, Guido

    2014-03-28

    US scanning has been defined as the urologist's stethoscope. These recommendations have been drawn up with the aim of ensuring minimum standards of excellence for ultrasound imaging in urological and andrological practice. A series of essential recommendations are made, to be followed during ultrasound investigations in kidney, prostate, bladder, scrotal and penile diseases. Members of the Imaging Working Group of the Italian Society of Urology (SIU) in collaboration with the Italian Society of Ultrasound in Urology, Andrology and Nephrology (SIEUN) identified expert Urologists, Andrologists, Nephrologists and Radiologists. The recommendations are based on review of the literature, previously published recommendations, books and the opinions of the experts. The final document was reviewed by national experts, including members of the Italian Society of Radiology. Recommendations are listed in 5 chapters, focused on: kidney, bladder, prostate and seminal vesicles, scrotum and testis, penis, including penile echo-doppler. In each chapter clear definitions are made of: indications, technological standards of the devices, the method of performance of the investigation. The findings to be reported are described and discussed, and examples of final reports for each organ are included. In the tables, the ultrasound features of the principal male uro-genital diseases are summarized. Diagnostic accuracy and second level investigations are considered. Ultrasound is an integral part of the diagnosis and follow-up of diseases of the urinary system and male genitals in patients of all ages, in both the hospital and outpatient setting. These recommendations are dedicated to enhancing communication and evidence-based medicine in an inter- and multi-disciplinary approach. The ability to perform and interpret ultrasound imaging correctly has become an integral part of clinical practice in uro-andrology, but intra and inter-observer variability is a well known limitation. These

  4. Target diagnostic system for the National Ignition Facility (NIF)

    International Nuclear Information System (INIS)

    Leeper, R.J.; Chandler, G.A.; Cooper, G.W.; Derzon, M.S.

    1996-01-01

    A review of recent progress on the design of a diagnostic system proposed for ignition target experiments on the National Ignition Facility (NIF) will be presented. This diagnostic package contains an extensive suite of optical, x-ray, gamma-ray, and neutron diagnostics that enable measurements of the performance of both direct and indirect driven NIF targets. The philosophy used in designing all of the diagnostics in the set has emphasized redundant and independent measurement of fundamental physical quantities relevant to the operation of the NIF target. A unique feature of these diagnostics is that they are being designed to be capable of operating, in the high radiation, EMP, and debris backgrounds expected on the NIF facility. The diagnostic system proposed can be categorized into three broad areas: laser characterization, hohlraum characterization, and capsule performance diagnostics. The operating principles of a representative instrument from each class of diagnostic employed in this package will be summarized and illustrated with data obtained in recent prototype diagnostic tests

  5. Ultrasound elastography in diagnosis and follow-up for patients with chronic recurrent parotitis.

    Science.gov (United States)

    Zengel, Pamela; Reichel, Christoph Andreas; Vincek, Teresa; Clevert, Dirk André

    2017-01-01

    Chronic recurrent parotitis (CRP) is a non-obstructive disease with episodes characterized by painful swelling of the parotid gland. It presents in both a juvenile and an adult form, with no clear information on its actual origin. Diagnosis is based on patient medical history and ultrasound examination but is frequently not correctly identified. Acoustic Radiation Force Impulse Imaging (ARFI) is a novel ultrasound elastography technology that has recently been implemented in the diagnostic work-up of patients with malignancies. This study aimed to answer whether ARFI can reasonably be employed in the initial examination and follow-up during therapy in patients with CRP. Mechanical tissue properties of the salivary glands were analyzed by ARFI in 37 parotid glands of patients with CRP. Having integrated ARFI into our diagnostic protocol for CRP, affected parotid glands were found to exhibit lower tissue elasticity compared to both healthy contralateral glands in the same individuals as well as those of healthy individuals. Most importantly, this method enabled us to quantitatively assess the patient benefit of therapy regarding the recovery of the glands' diseased parenchyma. ARFI provides a quick, easy, and reliable diagnostic tool for the assessment of disease severity and progression in patients with CRP that can be seamlessly implemented into preexisting ultrasound protocols.

  6. Thioaptamer Diagnostic System, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — AM Biotechnologies (AM) in partnership with Sandia National Laboratories will develop a Thioaptamer Diagnostic System (TDS) in response to Topic X10.01 Reusable...

  7. Severity of ASD symptoms and their correlation with the presence of copy number variations and exposure to first trimester ultrasound.

    Science.gov (United States)

    Webb, Sara Jane; Garrison, Michelle M; Bernier, Raphael; McClintic, Abbi M; King, Bryan H; Mourad, Pierre D

    2017-03-01

    Current research suggests that incidence and heterogeneity of autism spectrum disorder (ASD) symptoms may arise through a variety of exogenous and/or endogenous factors. While subject to routine clinical practice and generally considered safe, there exists speculation, though no human data, that diagnostic ultrasound may also contribute to ASD severity, supported by experimental evidence that exposure to ultrasound early in gestation could perturb brain development and alter behavior. Here we explored a modified triple hit hypothesis [Williams & Casanova, ] to assay for a possible relationship between the severity of ASD symptoms and (1) ultrasound exposure (2) during the first trimester of pregnancy in fetuses with a (3) genetic predisposition to ASD. We did so using retrospective analysis of data from the SSC (Simon's Simplex Collection) autism genetic repository funded by the Simons Foundation Autism Research Initiative. We found that male children with ASD, copy number variations (CNVs), and exposure to first trimester ultrasound had significantly decreased non-verbal IQ and increased repetitive behaviors relative to male children with ASD, with CNVs, and no ultrasound. These data suggest that heterogeneity in ASD symptoms may result, at least in part, from exposure to diagnostic ultrasound during early prenatal development of children with specific genetic vulnerabilities. These results also add weight to on-going concerns expressed by the FDA about non-medical use of diagnostic ultrasound during pregnancy. Autism Res 2017, 10: 472-484. © 2016 International Society for Autism Research, Wiley Periodicals, Inc. © 2016 International Society for Autism Research, Wiley Periodicals, Inc.

  8. [Magnetic resonance imaging as a prenatal diagnostic tool supplementary to ultrasound in diagnosing fetal and gestational abnormalities].

    Science.gov (United States)

    Porat, Shay; Agid, Ronit; Elchalal, Uriel; Ezra, Yossi; Gomori, J Moshe; Nadjari, Michelle

    2002-04-01

    The use of Magnetic Resonance Imaging (MRI) as a prenatal and gestational imaging modality supplementary to ultrasound has become widespread with the advent of rapid MR sequences in the last few years. These sequences allow acquisition of high-resolution images of the fetus in a single breath-holding period of the mother, with minimal fetal motion artifacts. We describe our experience with this modality in the diagnosis of prenatal and gestational abnormalities. The study population consisted of 39 pregnant women who had a total of 40 MRI examinations from 7/1998 to 7/2000. The indication for all examinations was a suspected fetal or gestational abnormality as suggested by ultrasound scan, laboratory tests or by family history. In 31 cases (77.5%) a correlation was found between the ultrasound findings and the MR imaging, of which in 6 cases (15%) the MRI added new valuable information. In 9 cases (22.5%) the MRI ruled out findings suspected by ultrasound. The prenatal findings were compared with postnatal clinical follow-up, imaging or pathology report in 26 cases (66.6%). In two cases the clinical outcome and postnatal imaging were discordant with the prenatal imaging findings in ultrasound and MRI. Although not proven, MRI is considered safe during pregnancy because it does not use ionizing radiation. It depicts fetal anatomy and pathology well. Also uterine, placental and other maternal structures are well demonstrated. This tool is useful in cases in which there is a suspicion of a malformed fetus or abnormal placenta by an ultrasound examination or in cases in which an ultrasound examination is limited by technical factors. MRI was found to help parents and doctors decide about the fate of a suspected abnormal pregnancy by adding valuable information supplemental to ultrasound examination.

  9. Discrimination between Newly Formed and Aged Thrombi Using Empirical Mode Decomposition of Ultrasound B-Scan Image

    Directory of Open Access Journals (Sweden)

    Jui Fang

    2015-01-01

    Full Text Available Ultrasound imaging is a first-line diagnostic method for screening the thrombus. During thrombus aging, the proportion of red blood cells (RBCs in the thrombus decreases and therefore the signal intensity of B-scan can be used to detect the thrombus age. To avoid the effect of system gain on the measurements, this study proposed using the empirical mode decomposition (EMD of ultrasound image as a strategy to classify newly formed and aged thrombi. Porcine blood samples were used for the in vitro induction of fresh and aged thrombi (at hematocrits of 40%. Each thrombus was imaged using an ultrasound scanner at different gains (15, 20, and 30 dB. Then, EMD of ultrasound signals was performed to obtain the first and second intrinsic mode functions (IMFs, which were further used to calculate the IMF-based echogenicity ratio (IER. The results showed that the performance of using signal amplitude of B-scan to reflect the thrombus age depends on gain. However, the IER is less affected by the gain in discriminating between fresh and aged thrombi. In the future, ultrasound B-scan combined with the EMD may be used to identify the thrombus age for the establishment of thrombolytic treatment planning.

  10. Ultrasound-guided core needle biopsy for breast cancer

    International Nuclear Information System (INIS)

    Naqvi, S.Q.H.; Solangi, R.A.; Memon, M.; Solangi, R.A.

    2008-01-01

    To evaluate the efficacy of ultrasound-guided core needle biopsy (US-CNB) as a preoperative diagnostic modality for breast cancer. Females with solid and/or intermediate breast lesions visualized on ultrasonography. Apart from clinical work-up, all the above mentioned patients underwent ultrasound-guided core needle biopsy and excisional biopsy of their breast lesions. The histopathological diagnosis on ultrasound-guided core needle biopsy was then compared with the findings of the excisional biopsy. Out of the total 93 cases, 47(50.5%) had benign lesions on ultrasound; US-CNB showed 24 as fibroadenomata, four with chronic non-specific mastitis, five chronic suppurative mastitis, one tuberculosis, four fat necrosis, two lactational adenoma and seven cases with benign ductal hyperplasia without atypia. Nine (9.7%) cases showed suspicious abnormality on ultrasound; US-CNB revealed five cases with atypical ductal hyperplasia, one ductal carcinoma in situ and three invasive ductal carcinoma. Thirty seven (39.8%) cases were highly suggestive of malignancy on ultrasound; US-CNB showed 34 as invasive ductal carcinoma, two invasive lobular and one medullary carcinoma. Excisional biopsy confirmed the diagnosis of ultrasound-guided core needle biopsy in all cases except four; one case of chronic suppurative mastitis was diagnosed as that of tuberculosis and three cases of atypial ductal hyperplasia as invasive ductal carcinoma. Hence there was no false positive case, but four (4.3%) false negative cases. The sensitivity of the US-CNB was thus 100% and specificity 91.1%. Ultrasound guided core needle biopsy is a satisfactory procedure for the histopathological diagnosis of breast lesions. Any unsatisfactory, suspicious or atypical change on US-CNB should be followed by an open biopsy. (author)

  11. Diagnostic Accuracy of Ultrasound, Contrast-enhanced CT, and Conventional MRI for Differentiating Leiomyoma From Leiomyosarcoma.

    Science.gov (United States)

    Gaetke-Udager, Kara; McLean, Karen; Sciallis, Andrew P; Alves, Timothy; Maturen, Katherine E; Mervak, Benjamin M; Moore, Andreea G; Wasnik, Ashish P; Erba, Jake; Davenport, Matthew S

    2016-10-01

    This study aimed to determine whether uterine leiomyoma can be distinguished from uterine leiomyosarcoma on ultrasound (US), computed tomography (CT), and/or magnetic resonance imaging (MRI) without diffusion-weighted imaging. Institutional review board approval was obtained and informed consent was waived for this Health Insurance Portability and Accountability Act-compliant retrospective case-control diagnostic accuracy study. All subjects with resected uterine leiomyosarcoma diagnosed over a 17-year period (1998-2014) at a single institution for whom pre-resection US (n = 10), CT (n = 11), or MRI (n = 7) was available were matched by tumor size and imaging modality with 28 subjects with resected uterine leiomyoma. Six blinded radiologists (three attendings, three residents) assigned 5-point Likert scores for the following features: (1) margins, (2) necrosis, (3) hemorrhage, (4) vascularity, (5) calcifications, (6) heterogeneity, and (7) likelihood of malignancy (primary end point). Mean suspicion scores were calculated and receiver operating characteristic curves were generated. The ability of individual morphologic features to predict malignancy was assessed with logistic regression. Mean suspicion scores were 2.5 ± 1.2 (attendings) and 2.4 ± 1.3 (residents) for leiomyoma, and 2.7 ± 1.3 (attendings) and 2.7 ± 1.4 (residents) for leiomyosarcoma. The areas under the receiver operating characteristic curves (range: 0.330-0.685) were not significantly different from chance, either overall (P = .36-.88) or by any modality (P = .28-.96), for any reader. Reader experience had no effect on diagnostic accuracy. No morphologic parameter was significantly predictive of malignancy (P = .10-.97). Uterine leiomyoma cannot be differentiated accurately from leiomyosarcoma on US, CT, or MRI without diffusion-weighted imaging. Copyright © 2016 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  12. The Role of Acoustic Cavitation in Ultrasound-triggered Drug Release from Echogenic Liposomes

    Science.gov (United States)

    Kopechek, Jonathan A.

    Cardiovascular disease (CVD) is the leading cause of death in the United States and globally. CVD-related mortality, including coronary heart disease, heart failure, or stroke, generally occurs due to atherosclerosis, a condition in which plaques build up within arterial walls, potentially causing blockage or rupture. Targeted therapies are needed to achieve more effective treatments. Echogenic liposomes (ELIP), which consist of a lipid membrane surrounding an aqueous core, have been developed to encapsulate a therapeutic agent and/or gas bubbles for targeted delivery and ultrasound image enhancement. Under certain conditions ultrasound can cause nonlinear bubble growth and collapse, known as "cavitation." Cavitation activity has been associated with enhanced drug delivery across cellular membranes. However, the mechanisms of ultrasound-mediated drug release from ELIP have not been previously investigated. Thus, the objective of this dissertation is to elucidate the role of acoustic cavitation in ultrasound-mediated drug release from ELIP. To determine the acoustic and physical properties of ELIP, the frequency-dependent attenuation and backscatter coefficients were measured between 3 and 30 MHz. The results were compared to a theoretical model by measuring the ELIP size distribution in order to determine properties of the lipid membrane. It was found that ELIP have a broad size distribution and can provide enhanced ultrasound image contrast across a broad range of clinically-relevant frequencies. Calcein, a hydrophilic fluorescent dye, and papaverine, a lipophilic vasodilator, were separately encapsulated in ELIP and exposed to color Doppler ultrasound pulses from a clinical diagnostic ultrasound scanner in a flow system. Spectrophotometric techniques (fluorescence and absorbance measurements) were used to detect calcein or papaverine release. As a positive control, Triton X-100 (a non-ionic detergent) was added to ELIP samples not exposed to ultrasound in order

  13. Diagnostic accuracy of contrast enhanced ultrasound in patients with blunt abdominal trauma presenting to the emergency department: a systematic review and meta-analysis.

    Science.gov (United States)

    Zhang, Zhongheng; Hong, Yucai; Liu, Ning; Chen, Yuhao

    2017-06-30

    We aimed to investigate the diagnostic accuracy of contrast-enhanced ultrasound (CEUS) in evaluating blunt abdominal trauma for patients presenting to the emergency department. Electronic search of Scopus and Pubmed was performed from inception to September 2016. Human studies investigating the diagnostic accuracy of CEUS in identifying abdominal solid organ injuries were included. Risk of bias was assessed using the QUADAS tool. A total of 10 studies were included in the study and 9 of them were included for meta-analysis. The log(DOR) values ranged from 3.80 (95% CI: 2.81-4.79) to 8.52 (95% CI: 4.58-12.47) in component studies. The combined log(DOR) was 6.56 (95% CI: 5.66-7.45). The Cochran's Q was 11.265 (p = 0.793 with 16 degrees of freedom), and the Higgins' I 2 was 0%. The CEUS had a sensitivity of 0.981 (95% CI: 0.868-0.950) and a false positive rate of 0.018 (95% CI: 0.010-0.032) for identifying parenchymal injuries, with an AUC of 0.984. CEUS performed at emergency department had good diagnostic accuracy in identifying abdominal solid organ injuries. CEUS can be recommended in monitoring solid organ injuries, especially for patients managed with non-operative strategy.

  14. Ultrasound diagnosis of pulmonary hypertension in children with chronic bronchopulmonary diseases

    International Nuclear Information System (INIS)

    Kondrat'ev, V.O.

    2000-01-01

    Ultrasound criteria of diagnosis of pulmonary hypertension and study this complication frequency in children with chronic bronchopulmonary diseases was determined. As diagnostic criteria of pulmonary hypertension Doppler echocardiographic indices of circulation in the pulmonary arteries are suggested

  15. Muscle blood volume assessment during exercise with Power Doppler Ultrasound

    NARCIS (Netherlands)

    Heres, H.M.; Tchang, B.C.Y.; Schoots, T.; Rutten, M.C.M.; van de Vosse, F.N.; Lopata, R.G.P.

    2016-01-01

    Assessment of perfusion adaptation in muscle during exercise can provide diagnostic information on cardiac and endothelial diseases. Power Doppler Ultrasound (PDUS) is known for its feasibility in the non-invasive measurement of moving blood volume (MBV), a perfusion related parameter. In this

  16. Beam profile diagnostics system for SDUV-FEL

    International Nuclear Information System (INIS)

    Xu Yichao; Han Lifeng; Chen Yongzhong

    2010-01-01

    A new beam profile diagnostics system for Shanghai Deep Ultraviolet Free Electron Laser (SDUV-FEL) has been developed based on industrial Ethernet, with good versatility and scalability. The system includes three major subsystems for image acquisition,pneumatic control and stepper motor control, respectively. Virtual instrument technology is adopted to drive the devices, and to develop the measurement software. In this paper,we describe the system structure, and its hardware and software design. The results of system commissioning are given as well. As an important diagnostic tool and data acquisition method, the system has been successfully applied to the measurement and control of the SDUV-FEL.(authors)

  17. Non invasive techniques for the study of the extracranial carotid arterial system

    International Nuclear Information System (INIS)

    Ameneiro Perez, Santiago; Alvarez Sanchez, Jose Antonio; Aldama Figueroa, Alfredo

    2000-01-01

    A review of the noninvasive diagnostic techniques that have been historically used to detect the stenoocclussive lesions of the extracranial carotid arterial system is made. The technological development and the new therapeutic criteria to prevent strokes caused by these lesions have encouraged research in this field. A review of the most used techniques at present: mode B ultrasound, duplex ultrasound and color duplex ultrasound, as well as of the advantages and disadvantages of each one is made. Nowadays, there are hemodynamic criteria together with these techniques that evaluate the stenosis degrees and the characteristics of the lesions with accuracy enough to substitute in most of the cases the invasive and more expensive diagnostic angiographic methods

  18. Development trends for diagnostic systems in nuclear power plants

    International Nuclear Information System (INIS)

    Kunze, U.; Pohl, U.

    1998-01-01

    Monitoring systems used in nuclear power plants have made remarkable progress over the past four or five years. Development has followed the trends and changes in philosophy for the purpose of monitoring systems in nuclear power plants: They are no longer expected to fulfill only safety tasks, the plant personnel require information on which to base condition-oriented maintenance. A new generation of monitoring and diagnostic systems has been developed by Siemens recently. This new generation, called Series '95, is PC-based. An overview is given for the KUeS '95 loose parts diagnostic system, the SUeS '95 vibration monitoring system, the FLUeS leak detection system and the SIPLUG valve diagnostics system. The objectives behind the development of these new systems are both safety-related and economic. The new systems improve the reliability and quality of monitoring techniques and incorporate better detection and diagnostic capabilities. Progress has also been made in automation of the systems so as to reduce routine work, give higher sensitivity for the monitoring task and reduce the scope of maintenance. (author)

  19. The efficacy of an ultrasound-guided core needle biopsy with an 18G cutting needle for the diagnosis of pancreatic diseases

    International Nuclear Information System (INIS)

    Jung, Sung Hwa; Park, Won Kyu; Chang, Jay Chun; Kim, Jae Woon; Cho, Jae Ho; Jang, Han Won; Lee, Jae Kyo; Choi, Joon Hyuk

    2008-01-01

    The objective of this study is to evaluate the efficacy and safety of an ultrasound-guided core needle biopsy with an 18G cutting needle in patients suspected of having a pancreatic disease by analyzing the diagnostic performance and complication rate. The study population comprised 35 consecutive patients who underwent an ultrasound-guided core needle biopsy using a high-speed biopsy gun accompanied with an 18G cutting-type needle between May of 2001 and October of 2005. The diagnostic performance (i.e., the acquisition rate and diagnostic accuracy) and complications associated with core needle biopsies were evaluated for its efficacy and safety. Thirty-six sessions of ultrasound-guided core needle biopsies were performed in 35 consecutive patients. All patients, except two (serous cystadenoma and autoimmune pancreatitis) were diagnosed with various subtypes of pancreatic cancer. The acquisition rate and diagnostic accuracy were 97% (35/36) and 94% (34/36), respectively. A complication occurred only in one patient (3%), which further proved to be a delayed complication (i.e., needle tract implantation). According to our findings, the ultrasound-guided core needle biopsy is a viable and safe method for the diagnosis of pancreatic diseases. Moreover, it enables the diagnosis of the pancreatic cancer subtype

  20. Comparison of barium swallow and ultrasound in diagnosis of gastro-oesophageal reflux in children.

    Science.gov (United States)

    Naik, D R; Bolia, A; Moore, D J

    1985-01-01

    Fifty one infants and older children with suspected gastro-oesophageal reflux entered a study comparing the diagnostic accuracy of a standard barium swallow examination with that of ultrasound scanning. All children were examined by both techniques. In 40 cases there was unequivocal agreement between the examinations. Of the remaining patients, four had definite reflux by ultrasonic criteria but showed no evidence of reflux on barium swallow examination, four had positive findings on ultrasound but showed only minimal reflux on barium swallow, and one showed minimal reflux on ultrasound but had a negative barium meal result. In two children the ultrasound study was inconclusive. Ultrasound has an important role in the diagnosis and follow up of patients under the age of 5 years with gastro-oesophageal reflux. Images FIG 1 FIG 2 PMID:3924317

  1. Ultrasound -- Pelvis

    Medline Plus

    Full Text Available ... frequently used to evaluate the reproductive and urinary systems. Ultrasound is safe, noninvasive and does not use ... and evaluate a variety of urinary and reproductive system disorders in both sexes without x-ray exposure. ...

  2. Proton storage ring (PSR) diagnostics and control system

    International Nuclear Information System (INIS)

    Clout, P.

    1983-01-01

    When any new accelerator or storage ring is built that advances the state of the art, the diagnostic system becomes extremely important in tuning the facility to full specification. This paper will discuss the various diagnostic devices planned or under construction for the PSR and their connection into the control system

  3. Combined ultrasound and MR imaging to guide focused ultrasound therapies in the brain

    Science.gov (United States)

    Arvanitis, Costas D.; Livingstone, Margaret S.; McDannold, Nathan

    2013-07-01

    Several emerging therapies with potential for use in the brain, harness effects produced by acoustic cavitation—the interaction between ultrasound and microbubbles either generated during sonication or introduced into the vasculature. Systems developed for transcranial MRI-guided focused ultrasound (MRgFUS) thermal ablation can enable their clinical translation, but methods for real-time monitoring and control are currently lacking. Acoustic emissions produced during sonication can provide information about the location, strength and type of the microbubble oscillations within the ultrasound field, and they can be mapped in real-time using passive imaging approaches. Here, we tested whether such mapping can be achieved transcranially within a clinical brain MRgFUS system. We integrated an ultrasound imaging array into the hemisphere transducer of the MRgFUS device. Passive cavitation maps were obtained during sonications combined with a circulating microbubble agent at 20 targets in the cingulate cortex in three macaques. The maps were compared with MRI-evident tissue effects. The system successfully mapped microbubble activity during both stable and inertial cavitation, which was correlated with MRI-evident transient blood-brain barrier disruption and vascular damage, respectively. The location of this activity was coincident with the resulting tissue changes within the expected resolution limits of the system. While preliminary, these data clearly demonstrate, for the first time, that it is possible to construct maps of stable and inertial cavitation transcranially, in a large animal model, and under clinically relevant conditions. Further, these results suggest that this hybrid ultrasound/MRI approach can provide comprehensive guidance for targeted drug delivery via blood-brain barrier disruption and other emerging ultrasound treatments, facilitating their clinical translation. We anticipate that it will also prove to be an important research tool that will

  4. Combined ultrasound and MR imaging to guide focused ultrasound therapies in the brain

    International Nuclear Information System (INIS)

    Arvanitis, Costas D; McDannold, Nathan; Livingstone, Margaret S

    2013-01-01

    Several emerging therapies with potential for use in the brain, harness effects produced by acoustic cavitation—the interaction between ultrasound and microbubbles either generated during sonication or introduced into the vasculature. Systems developed for transcranial MRI-guided focused ultrasound (MRgFUS) thermal ablation can enable their clinical translation, but methods for real-time monitoring and control are currently lacking. Acoustic emissions produced during sonication can provide information about the location, strength and type of the microbubble oscillations within the ultrasound field, and they can be mapped in real-time using passive imaging approaches. Here, we tested whether such mapping can be achieved transcranially within a clinical brain MRgFUS system. We integrated an ultrasound imaging array into the hemisphere transducer of the MRgFUS device. Passive cavitation maps were obtained during sonications combined with a circulating microbubble agent at 20 targets in the cingulate cortex in three macaques. The maps were compared with MRI-evident tissue effects. The system successfully mapped microbubble activity during both stable and inertial cavitation, which was correlated with MRI-evident transient blood–brain barrier disruption and vascular damage, respectively. The location of this activity was coincident with the resulting tissue changes within the expected resolution limits of the system. While preliminary, these data clearly demonstrate, for the first time, that it is possible to construct maps of stable and inertial cavitation transcranially, in a large animal model, and under clinically relevant conditions. Further, these results suggest that this hybrid ultrasound/MRI approach can provide comprehensive guidance for targeted drug delivery via blood–brain barrier disruption and other emerging ultrasound treatments, facilitating their clinical translation. We anticipate that it will also prove to be an important research tool that

  5. Ultrasound versus liver function tests for diagnosis of common bile duct stones.

    Science.gov (United States)

    Gurusamy, Kurinchi Selvan; Giljaca, Vanja; Takwoingi, Yemisi; Higgie, David; Poropat, Goran; Štimac, Davor; Davidson, Brian R

    2015-02-26

    Ultrasound and liver function tests (serum bilirubin and serum alkaline phosphatase) are used as screening tests for the diagnosis of common bile duct stones in people suspected of having common bile duct stones. There has been no systematic review of the diagnostic accuracy of ultrasound and liver function tests. To determine and compare the accuracy of ultrasound versus liver function tests for the diagnosis of common bile duct stones. We searched MEDLINE, EMBASE, Science Citation Index Expanded, BIOSIS, and Clinicaltrials.gov to September 2012. We searched the references of included studies to identify further studies and systematic reviews identified from various databases (Database of Abstracts of Reviews of Effects, Health Technology Assessment, Medion, and ARIF (Aggressive Research Intelligence Facility)). We did not restrict studies based on language or publication status, or whether data were collected prospectively or retrospectively. We included studies that provided the number of true positives, false positives, false negatives, and true negatives for ultrasound, serum bilirubin, or serum alkaline phosphatase. We only accepted studies that confirmed the presence of common bile duct stones by extraction of the stones (irrespective of whether this was done by surgical or endoscopic methods) for a positive test result, and absence of common bile duct stones by surgical or endoscopic negative exploration of the common bile duct, or symptom-free follow-up for at least six months for a negative test result as the reference standard in people suspected of having common bile duct stones. We included participants with or without prior diagnosis of cholelithiasis; with or without symptoms and complications of common bile duct stones, with or without prior treatment for common bile duct stones; and before or after cholecystectomy. At least two authors screened abstracts and selected studies for inclusion independently. Two authors independently collected data from

  6. Ultrasound assisted nucleation and growth characteristics of glycine polymorphs--a combined experimental and analytical approach.

    Science.gov (United States)

    Renuka Devi, K; Raja, A; Srinivasan, K

    2015-05-01

    For the first time, the effect of ultrasound in the diagnostic frequency range of 1-10 MHz on the nucleation and growth characteristics of glycine has been explored. The investigation employing the ultrasonic interferometer was carried out at a constant insonation time over a wide range of relative supersaturation from σ=-0.09 to 0.76 in the solution. Ultrasound promotes only α nucleation and completely inhibits both the β and γ nucleation in the system. The propagation of ultrasound assisted mass transport facilitates nucleation even at very low supersaturation levels in the solution. The presence of ultrasound exhibits a profound effect on nucleation and growth characteristics in terms of decrease in induction period, increase in nucleation rate and decrease in crystal size than its absence in the solution. With an increase in the frequency of ultrasound, a further decrease in induction period, increase in nucleation rate and decrease in the size of the crystal is noticed even at the same relative supersaturation levels. The increase in the nucleation rate explains the combined dominating effects of both the ultrasound frequency and the supersaturation in the solution. Analytically, the nucleation parameters of the nucleated polymorph have been deduced at different ultrasonic frequencies based on the classical nucleation theory and correlations with the experimental results have been obtained. Structural affirmation of the nucleated polymorph has been ascertained by powder X-ray diffraction. Copyright © 2014 Elsevier B.V. All rights reserved.

  7. Benchmarking Diagnostic Algorithms on an Electrical Power System Testbed

    Science.gov (United States)

    Kurtoglu, Tolga; Narasimhan, Sriram; Poll, Scott; Garcia, David; Wright, Stephanie

    2009-01-01

    Diagnostic algorithms (DAs) are key to enabling automated health management. These algorithms are designed to detect and isolate anomalies of either a component or the whole system based on observations received from sensors. In recent years a wide range of algorithms, both model-based and data-driven, have been developed to increase autonomy and improve system reliability and affordability. However, the lack of support to perform systematic benchmarking of these algorithms continues to create barriers for effective development and deployment of diagnostic technologies. In this paper, we present our efforts to benchmark a set of DAs on a common platform using a framework that was developed to evaluate and compare various performance metrics for diagnostic technologies. The diagnosed system is an electrical power system, namely the Advanced Diagnostics and Prognostics Testbed (ADAPT) developed and located at the NASA Ames Research Center. The paper presents the fundamentals of the benchmarking framework, the ADAPT system, description of faults and data sets, the metrics used for evaluation, and an in-depth analysis of benchmarking results obtained from testing ten diagnostic algorithms on the ADAPT electrical power system testbed.

  8. Systematic Benchmarking of Diagnostic Technologies for an Electrical Power System

    Science.gov (United States)

    Kurtoglu, Tolga; Jensen, David; Poll, Scott

    2009-01-01

    Automated health management is a critical functionality for complex aerospace systems. A wide variety of diagnostic algorithms have been developed to address this technical challenge. Unfortunately, the lack of support to perform large-scale V&V (verification and validation) of diagnostic technologies continues to create barriers to effective development and deployment of such algorithms for aerospace vehicles. In this paper, we describe a formal framework developed for benchmarking of diagnostic technologies. The diagnosed system is the Advanced Diagnostics and Prognostics Testbed (ADAPT), a real-world electrical power system (EPS), developed and maintained at the NASA Ames Research Center. The benchmarking approach provides a systematic, empirical basis to the testing of diagnostic software and is used to provide performance assessment for different diagnostic algorithms.

  9. Beam diagnostic system for SSC on HIRFL central console

    International Nuclear Information System (INIS)

    Zhang Guixu; Wang Zhen; Huang Tuanhua

    1998-01-01

    The SSC ion beam diagnostic system on the console of HIRFL in institute of modern physics is presented. The information between console and diagnostic system can be transferred via DECnet communication. The central computer for HIRFL console is VAX-8350, the working computer of diagnostic system is changed from IBM PC/XT to COMPAQ 486, and the operating program is rewritten from FORTRAN to C. In order to communicate information, DECnet TTT function is put into both programs on the VAX and PC

  10. Technical characterization of an ultrasound source for noninvasive thermoablation by high-intensity focused ultrasound.

    Science.gov (United States)

    Köhrmann, K U; Michel, M S; Steidler, A; Marlinghaus, E; Kraut, O; Alken, P

    2002-08-01

    To develop a generator for high-intensity focused ultrasound (HIFU, a method of delivering ultrasonic energy with resultant heat and tissue destruction to a tight focus at a selected depth within the body), designed for extracorporeal coupling to allow various parenchymal organs to be treated. The ultrasound generated by a cylindrical piezo-ceramic element is focused at a depth of 10 cm using a parabolic reflector with a diameter of 10 cm. A diagnostic B-mode ultrasonographic transducer is integrated into the source to allow the focus to be located in the target area. The field distribution of the sound pressure was measured in degassed water using a needle hydrophone. An ultrasound-force balance was used to determine the acoustic power. These measurements allowed the spatially averaged sound intensity to be calculated. The morphology and extent of tissue necrosis induced by HIFU was examined on an ex-vivo kidney model. The two-dimensional field distribution resulted in an approximately ellipsoidal focus of 32 x 4 mm (- 6 dB). The spatially maximum averaged sound intensity was 8591 W/cm2 at an electrical power of 400 W. The lesion caused to the ex-vivo kidney at this maximum generator power with a pulse duration of 2 s was a clearly delineated ellipsoidal coagulation necrosis up to 8.8 x 2.3 mm (length x width) and with central liquefied necrosis of 7.9 x 1.9 mm. This newly developed ultrasound generator with a focal length of 10 cm can induce clear necrosis in parenchymal tissue. Because of its specific configuration and the available power range of the ultrasound generator, there is potential for therapeutic noninvasive ablation of tissue deep within a patient's body.

  11. Instrumental tactile diagnostics in robot-assisted surgery

    Directory of Open Access Journals (Sweden)

    Solodova RF

    2016-10-01

    Full Text Available Rozalia F Solodova,1,2 Vladimir V Galatenko,1,2 Eldar R Nakashidze,3 Igor L Andreytsev,3 Alexey V Galatenko,1 Dmitriy K Senchik,2 Vladimir M Staroverov,1 Vladimir E Podolskii,1,2 Mikhail E Sokolov,1,2 Victor A Sadovnichy1,2 1Faculty of Mechanics and Mathematics, 2Institute of Mathematical Studies of Complex Systems, Lomonosov Moscow State University, 31st Surgery Department, Clinical Hospital 31, Moscow, Russia Background: Robotic surgery has gained wide acceptance due to minimizing trauma in patients. However, the lack of tactile feedback is an essential limiting factor for the further expansion. In robotic surgery, feedback related to touch is currently kinesthetic, and it is mainly aimed at the minimization of force applied to tissues and organs. Design and implementation of diagnostic tactile feedback is still an open problem. We hypothesized that a sufficient tactile feedback in robot-assisted surgery can be provided by utilization of Medical Tactile Endosurgical Complex (MTEC, which is a novel specialized tool that is already commercially available in the Russian Federation. MTEC allows registration of tactile images by a mechanoreceptor, real-time visualization of these images, and reproduction of images via a tactile display. Materials and methods: Nine elective surgeries were performed with da Vinci™ robotic system. An assistant performed tactile examination through an additional port under the guidance of a surgeon during revision of tissues. The operating surgeon sensed registered tactile data using a tactile display, and the assistant inspected the visualization of tactile data. First, surgeries where lesion boundaries were visually detectable were performed. The goal was to promote cooperation between the surgeon and the assistant and to train them in perception of the tactile feedback. Then, instrumental tactile diagnostics was utilized in case of visually undetectable boundaries. Results: In robot-assisted surgeries where lesion

  12. Copper oxide loaded PLGA nanospheres: towards a multifunctional nanoscale platform for ultrasound-based imaging and therapy

    Science.gov (United States)

    Perlman, Or; Weitz, Iris S.; Sivan, Sarit S.; Abu-Khalla, Hiba; Benguigui, Madeleine; Shaked, Yuval; Azhari, Haim

    2018-05-01

    Copper oxide nanoparticles (CuO-NPs) are increasingly becoming the subject of investigation exploring their potential use for diagnostic and therapeutic purposes. Recent work has demonstrated their anticancer potential, as well as contrast agent capabilities for magnetic resonance imaging (MRI) and through-transmission ultrasound. However, no capability of CuO-NPs has been demonstrated using conventional ultrasound systems, which, unlike the former, are widely deployed in the clinic. Furthermore, in spite of their potential as multifunctional nano-based materials for diagnosis and therapy, CuO-NPs have been delayed from further clinical application due to their inherent toxicity. Herein, we present the synthesis of a novel nanoscale system, composed of CuO-loaded PLGA nanospheres (CuO-PLGA-NS), and demonstrate its imaging detectability and augmented heating effect by therapeutic ultrasound. The CuO-PLGA-NS were prepared by a double emulsion (W/O/W) method with subsequent solvent evaporation. They were characterized as sphere-shaped, with size approximately 200 nm. Preliminary results showed that the viability of PANC-1, human pancreatic adenocarcinoma cells was not affected after 72 h exposure to CuO-PLGA-NS, implying that PLGA masks the toxic effects of CuO-NPs. A systematic ultrasound imaging evaluation of CuO-PLGA-NS, using a conventional system, was performed in vitro and ex vivo using poultry heart and liver, and also in vivo using mice, all yielding a significant contrast enhancement. In contrast to CuO-PLGA-NS, neither bare CuO-NPs nor blank PLGA-NS possess these unique advantageous ultrasonic properties. Furthermore, CuO-PLGA-NS accelerated ultrasound-induced temperature elevation by more than 4 °C within 2 min. The heating efficiency (cumulative equivalent minutes at 43 °C) was increased approximately six-fold, demonstrating the potential for improved ultrasound ablation. In conclusion, CuO-PLGA-NS constitute a versatile platform, potentially useful for

  13. Potential use of an ultrasound antifouling technology as a ballast water treatment system

    Science.gov (United States)

    Estévez-Calvar, Noelia; Gambardella, Chiara; Miraglia, Francesco; Pavanello, Giovanni; Greco, Giuliano; Faimali, Marco; Garaventa, Francesca

    2018-03-01

    The aim of this study was to investigate, at a laboratory scale, the potentialities of an ultrasound-based treatment initially designed to eliminate fouling, as a ballast water treatment system. Therefore, early life stages of three different zooplanktonic species (Amphibalanus amphitrite, Brachionus plicatilis and Artemia salina) were exposed to ultrasound waves (20-22 kHz). The experimental set up included static assays with variations of time exposure (30 s, 60 s and 30 s on/60 s off/30 s on), material of tanks (stainless steel, galvanized steel and plastic) and position of the ultrasound source. Results showed that the treatment efficacy increased from 30 to 60 s and no differences were registered between 60 s-continuous exposure and pulse exposure. The highest efficacy was observed in Experiment I (metal-to-metal contact assay) with a mortality value of 93-95% for B. plicatilis and A. salina. It consisted of organisms located inside stainless steel tubes that were located in direct contact with the ultrasound source and treated for 60 s. Further, we found that, generally, A. amphitrite and B. plicatilis were the most resistant species to the ultrasound treatment whereas A. salina was the most sensitive. We further discuss that US may unlikely be used for commercial vessels, but may be used to treat ballast water in smaller ballast tanks as on board of mega yachts.

  14. Eyeball test using abdominal ultrasound unit

    International Nuclear Information System (INIS)

    Choi, Chun Kyu; Lee, Yong Woo; Cheung, Hwan

    1984-01-01

    Ultrasonography is a wide diagnostic use for its desirable quality that it causes no radiation hazard to the patient and allows to test him without causing pains, while affording much valued diagnostic information. Since Mundt reported in 1955 that Ultrasonography can be used for testing the eyeball, it has widely been used for clinical purpose, but in Korea many difficulties are being exist in the sonographic evaluation of the eyeball due to storage of the exclusive Ultrasound units for eyeball diagnosis. This treatise describes eyeball test methods along with clinical instances observed by a compound scanner for abdomen scan mounted with an eyeball transducer of a frequency as high as 5 to 7.5MHz and using water bag

  15. Out of hospital point of care ultrasound: current use models and future directions.

    Science.gov (United States)

    Nelson, B P; Sanghvi, A

    2016-04-01

    Ultrasound has evolved from a modality that was once exclusively reserved to certain specialities of its current state, in which its portability and durability lend to its broadly increasing applications. This review describes portable ultrasound in the hospital setting and its comparison to gold standard imaging modalities. Also, this review summarizes current literature describing portable ultrasound use in prehospital, austere and remote environments, highlighting successes and barriers to use in these environments. Prehospital ultrasound has the ability to increase diagnostic ability and allow for therapeutic intervention in the field. In austere environments, ultrasound may be the only available imaging modality and thus can guide diagnosis, therapeutics and determine which patients may need emergent transfer to a healthcare facility. The most cutting edge applications of portable ultrasound employ telemedicine to obtain and transmit ultrasound images. This technology and ability to transmit images via satellite and cellular transmission can allow for even novice users to obtain interpretable images in austere environments. Portable ultrasound uses have steadily grown and will continue to do so with the introduction of more portable and durable technologies. As applications continue to grow, certain technologic considerations and future directions are explored.

  16. Minimum training requirement in ultrasound imaging of peripheral arterial disease.

    Science.gov (United States)

    Eiberg, J P; Hansen, M A; Grønvall Rasmussen, J B; Schroeder, T V

    2008-09-01

    To demonstrate the minimum training requirement when performing ultrasound of peripheral arterial disease. Prospective and blinded comparative study. 100 limbs in 100 consecutive patients suffering from peripheral arterial disease, 74% suffering critical limb ischemia, were enrolled during a 9 months period. One physician with limited ultrasound experience performed all the ultrasound examinations of the arteries of the most symptomatic limb. Before enrolling any patients 15 duplex ultrasound examinations were performed supervised by an experienced vascular technologist. All patients had a digital subtraction arteriography performed by an experienced vascular radiologist, unaware of the ultrasound result. The number of insufficiently insonated segments (non-diagnostic segments) was significantly reduced during the study; from 9% among the initial 50 limbs to 2% among the last 50 limbs (Pultrasound and arteriography from the initial 50 patients (overall Kappa=0.66, (95%-CI: 0.60-0.72); supragenicular Kappa=0.73 (95%-CI: 0.64-0.82); infragenicular Kappa=0.61 (95%-CI: 0.54-0.69)) to the last 50 patients (overall Kappa=0.66 (95%-CI: 0.60-0.72), supragenicular Kappa=0.67 (95%-CI: 0.57-0.76); infragenicular Kappa=0.66 (95%-CI: 0.58-0.73)). The minimum training requirement in ultrasound imaging of peripheral arterial disease appears to be less than 50 ultrasound examinations (probably only 15 examinations) for the supragenicular segments and 100 examinations for the infragenicular segments.

  17. Diagnostic imaging of hypertrophic pyloric stenosis (HPS)

    International Nuclear Information System (INIS)

    Frkovic, M.; Seronja Kuhar, M.; Perhoc, Z.; Barbaric-Babic, V.; Molnar, M.; Vukovic, J.

    2001-01-01

    Background. Imaging of the abdomen in children with suspected hypertrophic pyloric stenosis has been traditionally performed by plain film radiography and upper gastrointestinal contrast studies. In many clinical situations, this approach has been modified or replaced by ultrasound examination. The authors aimed to analyse the value of diagnostic algorithm in children with hypertrophic pyloric stenosis confirmed at surgery in our hospital. Patients and methods. The authors made a five year retrospective review of hospital records of all children operated on for HPS in Clinical Hospital Centre Zagreb - Rebro and found out that 14 boys, between 2 (17 days) and 10 weeks of life (75 days) underwent surgery due to HPS. Results. Specific radiographic signs were: string sign, double track sign, elongation and narrowing of pyloric canal, mushroom sign, gastric distension with fluid and beak sign. Ultrasound was performed in 9 patients, one of them was false negative (sonographer admitted that he had no experience), the rest were positive. Conclusions. If the physical examination is negative or equivocal, sonography by an experienced sonographer must be performed. If the ultrasound finding is negative, than the infant should undergo to barium upper gastrointestinal studies (UGI). If HPS isn't a primary diagnostic question, it's better to perform UGI first in order to make a correct diagnosis. (author)

  18. Diagnostic accuracy of fundal height and handheld ultrasound-measured abdominal circumference to screen for fetal growth abnormalities

    Science.gov (United States)

    Haragan, Adriane F.; Hulsey, Thomas C.; Hawk, Angela F.; Newman, Roger B.; Chang, Eugene Y.

    2015-01-01

    OBJECTIVE We sought to compare fundal height and handheld ultrasound–measured fetal abdominal circumference (HHAC) for the prediction of fetal growth restriction (FGR) or large for gestational age. STUDY DESIGN This was a diagnostic accuracy study in nonanomalous singleton pregnancies between 24 and 40 weeks’ gestation. Patients underwent HHAC and fundal height measurement prior to formal growth ultrasound. FGR was defined as estimated fetal weight less than 10%, whereas large for gestational age was defined as estimated fetal weight greater than 90%. Sensitivity and specificity were calculated and compared using methods described elsewhere. RESULTS There were 251 patients included in this study. HHAC had superior sensitivity and specificity for the detection of FGR (sensitivity, 100% vs 42.86%) and (specificity, 92.62% vs 85.24%). HHAC had higher specificity but lower sensitivity when screening for LGA (specificity, 85.66% vs 66.39%) and (sensitivity, 57.14% vs 71.43%). CONCLUSION HHAC could prove to be a valuable screening tool in the detection of FGR. Further studies are needed in a larger population. PMID:25818672

  19. Ultrasound pregnancy

    Science.gov (United States)

    Pregnancy sonogram; Obstetric ultrasonography; Obstetric sonogram; Ultrasound - pregnancy; IUGR - ultrasound; Intrauterine growth - ultrasound; Polyhydramnios - ultrasound; Oligohydramnios - ultrasound; ...

  20. Diagnostic system and diagnostic experiences at the Paks Nuclear Power Plant

    International Nuclear Information System (INIS)

    Katona, Tamas

    1986-01-01

    The major functions of the diagnostic system of the first two units of the Paks Nuclear Power Plant are as follows: monitoring the mechanical integrity of the reactor and the primary coolant circuit by means of vibration diagnostics; leakage detection of the primary coolant circuit by means of high frequency sonic analysis; loose parts monitoring based on the analysis of high frequency signals of acceleration detectors; and monitoring the vibration state of the turbines and rotary machines by the latter method or by a procedure based on the detection of mechanical vibrations. Up-to-date vibration diagnostics is based on the information supplied by either acceleration detectors or pressure fluctuation detectors, or in-core and ex-core neutron detectors. (V.N.)

  1. A retrospective analysis of ultrasound-guided large core needle ...

    African Journals Online (AJOL)

    A retrospective analysis of ultrasound-guided large core needle biopsies of breast lesions at a regional public hospital in Durban, KwaZulu-Natal, South Africa. ... Objective: To assess the influence of technical variables on the diagnostic yield of breast specimens obtained by using US-LCNB, and the sensitivity of detecting ...

  2. Overview of data acquisition system for SST-1 diagnostics

    International Nuclear Information System (INIS)

    Sharma, Manika; Mansuri, Imran; Raval, Tushar; Sharma, A.L; Pradhan, S.

    2016-01-01

    Highlights: • An account of architecture and data acquisition activities of SST-1 data acquisition system (DAS) for SST-1 diagnostics and subsystems. • PXI based Data acquisition system and CAMAC based Data acquisition system for slow and fast plasma diagnostics. • SST-1 DAS interface and its communication with SST-1 central control system. Integration of SST-1 DAS with timing system. • SST-1 DAS data archival and data analysis. - Abstract: The recent first phase operations of SST-1 in short pulse mode have provided an excellent opportunity for the essential initial tests and benchmark of the SST-1 Data Acquisition System. This paper describes the SST-1 Data Acquisition systems (DAS), which with its heterogeneous composition and distributed architecture, aims to cover a wide range of slow to fast channels interfaced with a large set of diagnostics. The DAS also provides the essential user interface for data acquisition to cater both on and off-line data usage. The central archiving and retrieval service is based on a dual step architecture involving a combination of Network Attached Server (NAS) and a Storage Area Network (SAN). SST-1 Data Acquisition Systems have been reliably operated in the SST-1 experimental campaigns. At present different distributed DAS caters the need of around 130 channels from different SST-1 diagnostics and its subsystems. PXI based DAS and CAMAC based DAS have been chosen to cater the need, with sampling rates varying from 10Ksamples/sec to 1Msamples/sec. For these large sets of channels acquiring from individual diagnostics and subsystems has been a combined setup, subjected to a gradual phase of optimization and tests resulting into a series of improvisations over the recent operations. In order to facilitate a reliable data acquisition, the model further integrates the objects of the systems with the Central Control System of SST-1 using the TCP/IP communication. The associated DAS software essentially addresses the

  3. Overview of data acquisition system for SST-1 diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Sharma, Manika, E-mail: bithi@ipr.res.in; Mansuri, Imran; Raval, Tushar; Sharma, A.L; Pradhan, S.

    2016-11-15

    Highlights: • An account of architecture and data acquisition activities of SST-1 data acquisition system (DAS) for SST-1 diagnostics and subsystems. • PXI based Data acquisition system and CAMAC based Data acquisition system for slow and fast plasma diagnostics. • SST-1 DAS interface and its communication with SST-1 central control system. Integration of SST-1 DAS with timing system. • SST-1 DAS data archival and data analysis. - Abstract: The recent first phase operations of SST-1 in short pulse mode have provided an excellent opportunity for the essential initial tests and benchmark of the SST-1 Data Acquisition System. This paper describes the SST-1 Data Acquisition systems (DAS), which with its heterogeneous composition and distributed architecture, aims to cover a wide range of slow to fast channels interfaced with a large set of diagnostics. The DAS also provides the essential user interface for data acquisition to cater both on and off-line data usage. The central archiving and retrieval service is based on a dual step architecture involving a combination of Network Attached Server (NAS) and a Storage Area Network (SAN). SST-1 Data Acquisition Systems have been reliably operated in the SST-1 experimental campaigns. At present different distributed DAS caters the need of around 130 channels from different SST-1 diagnostics and its subsystems. PXI based DAS and CAMAC based DAS have been chosen to cater the need, with sampling rates varying from 10Ksamples/sec to 1Msamples/sec. For these large sets of channels acquiring from individual diagnostics and subsystems has been a combined setup, subjected to a gradual phase of optimization and tests resulting into a series of improvisations over the recent operations. In order to facilitate a reliable data acquisition, the model further integrates the objects of the systems with the Central Control System of SST-1 using the TCP/IP communication. The associated DAS software essentially addresses the

  4. Optoacoustic diagnostic modality: from idea to clinical studies with highly compact laser diode-based systems

    Science.gov (United States)

    Esenaliev, Rinat O.

    2017-09-01

    Optoacoustic (photoacoustic) diagnostic modality is a technique that combines high optical contrast and ultrasound spatial resolution. We proposed using the optoacoustic technique for a number of applications, including cancer detection, monitoring of thermotherapy (hyperthermia, coagulation, and freezing), monitoring of cerebral blood oxygenation in patients with traumatic brain injury, neonatal patients, fetuses during late-stage labor, central venous oxygenation monitoring, and total hemoglobin concentration monitoring as well as hematoma detection and characterization. We developed and built optical parametric oscillator-based systems and multiwavelength, fiber-coupled highly compact, laser diode-based systems for optoacoustic imaging, monitoring, and sensing. To provide sufficient output pulse energy, a specially designed fiber-optic system was built and incorporated in ultrasensitive, wideband optoacoustic probes. We performed preclinical and clinical tests of the systems and the optoacoustic probes in backward mode for most of the applications and in forward mode for the breast cancer and cerebral applications. The high pulse energy and repetition rate allowed for rapid data acquisition with high signal-to-noise ratio from cerebral blood vessels, such as the superior sagittal sinus, central veins, and peripheral veins and arteries, as well as from intracranial hematomas. The optoacoustic systems were capable of automatic, real-time, continuous measurements of blood oxygenation in these blood vessels.

  5. MATLAB/Simulink Pulse-Echo Ultrasound System Simulator Based on Experimentally Validated Models.

    Science.gov (United States)

    Kim, Taehoon; Shin, Sangmin; Lee, Hyongmin; Lee, Hyunsook; Kim, Heewon; Shin, Eunhee; Kim, Suhwan

    2016-02-01

    A flexible clinical ultrasound system must operate with different transducers, which have characteristic impulse responses and widely varying impedances. The impulse response determines the shape of the high-voltage pulse that is transmitted and the specifications of the front-end electronics that receive the echo; the impedance determines the specification of the matching network through which the transducer is connected. System-level optimization of these subsystems requires accurate modeling of pulse-echo (two-way) response, which in turn demands a unified simulation of the ultrasonics and electronics. In this paper, this is realized by combining MATLAB/Simulink models of the high-voltage transmitter, the transmission interface, the acoustic subsystem which includes wave propagation and reflection, the receiving interface, and the front-end receiver. To demonstrate the effectiveness of our simulator, the models are experimentally validated by comparing the simulation results with the measured data from a commercial ultrasound system. This simulator could be used to quickly provide system-level feedback for an optimized tuning of electronic design parameters.

  6. Signal Processing in Medical Ultrasound B-mode Imaging

    International Nuclear Information System (INIS)

    Song, Tai Kyong

    2000-01-01

    Ultrasonic imaging is the most widely used modality among modern imaging device for medical diagnosis and the system performance has been improved dramatically since early 90's due to the rapid advances in DSP performance and VLSI technology that made it possible to employ more sophisticated algorithms. This paper describes 'main stream' digital signal processing functions along with the associated implementation considerations in modern medical ultrasound imaging systems. Topics covered include signal processing methods for resolution improvement, ultrasound imaging system architectures, roles and necessity of the applications of DSP and VLSI technology in the development of the medical ultrasound imaging systems, and array signal processing techniques for ultrasound focusing

  7. Ultrasound imaging with a micromotor; Micromotor ni yoru choonpa imaging

    Energy Technology Data Exchange (ETDEWEB)

    Oshiro, O.; Salimuzzaman, M.; Matani, A.; Chihara, K. [Nara Institute of Science and Technology, Nara (Japan); Asao, M. [Osaka National Hospital, Osaka (Japan)

    1998-03-01

    This paper describes a new ultrasound intravascular imaging system. In this system, an ultrasound probe consists of a micromotor, an ultrasound reflecting mirror attached with the micromotor and an ultrasound transducer. Ultrasound is scanned radially by a micromotor instead of a rotation transmitting wire and the rotation of the micromotor is performed and controlled by an external magnetic field. This ultrasound imaging system with a micromotor was applied to observe the inside of blood vessels through in vitro experiments. The preliminary results suggest that this system has the sufficient ability to define the blood vessel morphology and that the simple image processing enhances signal-to-noise ratio of the reconstructed image. 12 refs., 5 figs.

  8. Fuzzy logic algorithm for quantitative tissue characterization of diffuse liver diseases from ultrasound images.

    Science.gov (United States)

    Badawi, A M; Derbala, A S; Youssef, A M

    1999-08-01

    Computerized ultrasound tissue characterization has become an objective means for diagnosis of liver diseases. It is difficult to differentiate diffuse liver diseases, namely cirrhotic and fatty liver by visual inspection from the ultrasound images. The visual criteria for differentiating diffused diseases are rather confusing and highly dependent upon the sonographer's experience. This often causes a bias effects in the diagnostic procedure and limits its objectivity and reproducibility. Computerized tissue characterization to assist quantitatively the sonographer for the accurate differentiation and to minimize the degree of risk is thus justified. Fuzzy logic has emerged as one of the most active area in classification. In this paper, we present an approach that employs Fuzzy reasoning techniques to automatically differentiate diffuse liver diseases using numerical quantitative features measured from the ultrasound images. Fuzzy rules were generated from over 140 cases consisting of normal, fatty, and cirrhotic livers. The input to the fuzzy system is an eight dimensional vector of feature values: the mean gray level (MGL), the percentile 10%, the contrast (CON), the angular second moment (ASM), the entropy (ENT), the correlation (COR), the attenuation (ATTEN) and the speckle separation. The output of the fuzzy system is one of the three categories: cirrhosis, fatty or normal. The steps done for differentiating the pathologies are data acquisition and feature extraction, dividing the input spaces of the measured quantitative data into fuzzy sets. Based on the expert knowledge, the fuzzy rules are generated and applied using the fuzzy inference procedures to determine the pathology. Different membership functions are developed for the input spaces. This approach has resulted in very good sensitivities and specificity for classifying diffused liver pathologies. This classification technique can be used in the diagnostic process, together with the history

  9. Therapeutic ultrasound - The healing sound and its applications in oral diseases: The review of literature

    Directory of Open Access Journals (Sweden)

    Jyothirmai Koneru

    2012-01-01

    Full Text Available The application of medical ultrasound was mainly centered on the soft tissue diagnostic imaging until now. Recently, its use has been widened and adopted for various therapeutic purposes. It has been reported to facilitate the healing of bone fractures, wounds, apthous ulcers and temporomandibular disorders. In addition, ultrasound has also been shown to facilitate delivery of chemotherapeutic drugs into tumors, promote gene therapy to targeted tissues, and deliver thrombolytic drugs into blood clots. This article reviews the principles and current status of ultrasound-based treatments.

  10. Superficial Ultrasound Shear Wave Speed Measurements in Soft and Hard Elasticity Phantoms: Repeatability and Reproducibility Using Two Different Ultrasound Systems

    Science.gov (United States)

    Dillman, Jonathan R.; Chen, Shigao; Davenport, Matthew S.; Zhao, Heng; Urban, Matthew W.; Song, Pengfei; Watcharotone, Kuanwong; Carson, Paul L.

    2014-01-01

    Background There is a paucity of data available regarding the repeatability and reproducibility of superficial shear wave speed (SWS) measurements at imaging depths relevant to the pediatric population. Purpose To assess the repeatability and reproducibility of superficial shear wave speed (SWS) measurements acquired from elasticity phantoms at varying imaging depths using three different imaging methods, two different ultrasound systems, and multiple operators. Methods and Materials Soft and hard elasticity phantoms manufactured by Computerized Imaging Reference Systems, Inc. (Norfolk, VA) were utilized for our investigation. Institution #1 used an Acuson S3000 ultrasound system (Siemens Medical Solutions USA, Inc.) and three different shear wave imaging method/transducer combinations, while institution #2 used an Aixplorer ultrasound system (Supersonic Imagine) and two different transducers. Ten stiffness measurements were acquired from each phantom at three depths (1.0, 2.5, and 4.0 cm) by four operators at each institution. Student’s t-test was used to compare SWS measurements between imaging techniques, while SWS measurement agreement was assessed with two-way random effects single measure intra-class correlation coefficients and coefficients of variation. Mixed model regression analysis determined the effect of predictor variables on SWS measurements. Results For the soft phantom, the average of mean SWS measurements across the various imaging methods and depths was 0.84 ± 0.04 m/s (mean ± standard deviation) for the Acuson S3000 system and 0.90 ± 0.02 m/s for the Aixplorer system (p=0.003). For the hard phantom, the average of mean SWS measurements across the various imaging methods and depths was 2.14 ± 0.08 m/s for the Acuson S3000 system and 2.07 ± 0.03 m/s Aixplorer system (p>0.05). The coefficients of variation were low (0.5–6.8%), and inter-operator agreement was near-perfect (ICCs ≥0.99). Shear wave imaging method and imaging depth

  11. Accuracy of CESM versus conventional mammography and ultrasound in evaluation of BI-RADS 3 and 4 breast lesions with pathological correlation

    Directory of Open Access Journals (Sweden)

    Maha Helal

    2017-09-01

    Full Text Available Aim: Assess accuracy of contrast enhanced spectral mammography (CESM versus conventional mammography and ultrasound in evaluation of BI-RADS 3 and 4 breast lesions with pathological correlation. Patients and methods: Thirty female patients with 35 breast lesions diagnosed by conventional imaging as BI-RADS 3 and 4, presented to Women’s Imaging Unit of Radiology Department between January and December 2015, age ranged from 23 to 70 years. All patients underwent conventional mammography and ultrasound then CESM. Results: Patients divided into two groups, benign and malignant lesions group according to histological analysis. Mammography results that malignant lesions detected in 18/35 (51.4% while benign lesions 17/35 (48.6%. Ultrasound revealed 27/35 (77.1% lesions were malignant and 8/35 (22.9% lesions benign. But CESM, revealed 25/35 (71.4% lesions were malignant & 10/35 (28.6% lesions benign. Among 7 patients with multifocal/ multi-centric histologically proven malignant lesions, all detected by CESM 7/7 cases (100% versus 2/7 cases (28.6% and 6/7 cases (85.7% detected by mammography and ultrasound respectively. Based on, CESM had 95.2% sensitivity and 82.9% diagnostic accuracy. Conclusion: CESM has better diagnostic accuracy than mammography alone and mammography plus ultrasound. CESM has 82.9% diagnostic accuracy in comparison to 51.4% for mammography and 77.1% for ultrasound. Keywords: Breast lesions, CESM, BI-RADS lexicon

  12. A flexible simulator for training an early fault diagnostic system

    International Nuclear Information System (INIS)

    Marsiletti, M.; Santinelli, A.; Zuenkov, M.; Poletykin, A.

    1997-01-01

    An early fault diagnostic system has been developed addressed to timely trouble shooting in process plants during any operational modes. The theory of this diagnostic system is related with the usage of learning methods for automatic generation of knowledge bases. This approach enables the conversion of ''cause→effect'' relations into ''effect→possible-causes'' ones. The diagnostic rules are derived from the operation of a plant simulator according to a specific procedure. Flexibility, accuracy and high speed are the major characteristics of the training simulator, used to generate the diagnostic knowledge base. The simulator structure is very flexible, being based on LEGO code but allowing the use of practically any kind of FORTRAN routines (recently also ACSL macros has been introduced) as plant modules: this permits, when needed, a very accurate description of the malfunctions the diagnostic system should ''known''. The high speed is useful to shorten the ''learning'' phase of the diagnostic system. The feasibility of the overall system has been assessed, using as reference plant the conventional Sampierdarena (Italy) power station, that is a combined cycle plant dedicated to produce both electrical and heat power. The hardware configuration of this prototype system was made up of a network of a Hewlett-Packard workstation and a Digital VAX-Station. The paper illustrates the basic structure of the simulator used for this diagnostic system training purpose, as well as the theoretical background on which the diagnostic system is based. Some evidence of the effectiveness of the concept through the application to Sampierdarena 40 MW cogeneration plant is reported. Finally an outline of an ongoing application to a WWER-1000 plant is given; the operating system is, in this case, UNIX. (author)

  13. Primary ureteral carcinoma: MRI diagnosis and comparison with other diagnostic imaging facilities

    International Nuclear Information System (INIS)

    An Ningyu; Jiang Bo; Cai Youquan; Liang Yan

    2004-01-01

    Objective: To investigate MRI examination methods and imaging manifestations of primary ureteral carcinoma, and to evaluate its clinical values when comparing with other diagnostic imaging facilities. Methods: Eighty-seven cases of primary ureteral carcinoma who were operated within recent 8 years came into the study, among which, 35 cases had MRI examinations. For MRI examination, coronal heavy T 2 WI (water imaging) was performed to show the dilated ureter, then axial T 2 WI and T 1 WI were scanned at the obstruction level. 11 cases underwent additional Gd-DTPA dynamic contrast enhanced scans. The original pre-operative diagnostic reports of various imaging facilities were analyzed comparing with the results of operation and pathology. Results: MRI showed ureteral dilatation in 33 of 35 cases, no abnormal appearance in 1 case, and only primary kidney atrophy post renal transplantation in 1 case. Among the 33 cases with ureteral obstruction, soft mass at the obstruction level was detected on axial scans in 32 cases. The lesions showed gradual and homogeneous mild to moderate enhancement on contrast MRI. The overall employment rate of imaging facilities was as follows: ultrasound (94.3%), IVU (59.8%), CT (52.9%), MRI (40.2%), and RUP (35.6%). The accurate diagnostic rate was as follows :MRI (91.4%), RUP (80.6%), CT (63.0%), ultrasound (47.6%), and IVU (11.5%). Conclusion: Combination of MR water imaging and conventional sequences can demonstrate most primary ureteral carcinoma lesions and has a highest diagnostic accuracy among the current diagnostic imaging facilities. It should be taken as the first diagnostic imaging method of choice when primary ureteral carcinoma is suspected after ultrasound screening

  14. [Diagnostic imaging and acute abdominal pain].

    Science.gov (United States)

    Liljekvist, Mads Svane; Pommergaard, Hans-Christian; Burcharth, Jakob; Rosenberg, Jacob

    2015-01-19

    Acute abdominal pain is a common clinical condition. Clinical signs and symptoms can be difficult to interpret, and diagnostic imaging may help to identify intra-abdominal disease. Conventional X-ray, ultrasound (US) and computed tomography (CT) of the abdomen vary in usability between common surgical causes of acute abdominal pain. Overall, conventional X-ray cannot confidently diagnose or rule out disease. US and CT are equally trustworthy for most diseases. US with subsequent CT may enhance diagnostic precision. Magnetic resonance seems promising for future use in acute abdominal imaging.

  15. An expert system for turbogenerator diagnostics

    International Nuclear Information System (INIS)

    Bessenyei, Z.; Tomcsanyi, T.; Toth, Z.; Laczay, I.

    1992-01-01

    In 1990, an expert system for turbo-generator diagnostics (EST-D) was installed at the 3rd and 4th units of the Paks NPP (Hungary). The expert system is strongly integrated to the ARGUS II vibration monitoring and diagnostics system. The system works on IBM PC AT. The VEIKI's and the NPP's human experts were interviewed to fill up the knowledgebase. The system is able to identify 13 different faults of the parts of a turbogenerator. The knowledgebase consists of ca 200 rules. The rules were built in and the system was verified and validated using a model of the turbines and using the experiences gathered with ARGUS II during the last 3 years. The maintenance personnel is authorized to modify and/or extend the knowledgebase. The input data for evaluation come from measured vibration patterns produced by the ARGUS II system, database of events, and maintenance data input by the maintenance personnel. The expert system is based on the modified GENESYS 2.1 shell (developed by SZAMALK, Hungary). Some limitations from PC application were eliminated, and a new, independent explanation module and man-machine interface were developed. Using this man-machine interface, one of the basic goals of the expert system developments was achieved: the human experts contribution is not necessary for diagnoses. The operator of the diagnostics system is able to produce the reports of diagnoses. Of course the interface allows the human experts to see the diagnoses through. It should be mentioned, at the beginning of 1991, we installed a similar expert system at the 1st 1000 MW WWER type unit of the Kalinin NPP (Soviet Union). In this paper, the operation of the EST-D, the man-machine interface and the operational experiences of the first 4 months work are explained. 2 refs., 14 figs

  16. Clinical applications of SONIALVISION 100 digital diagnostic table system

    International Nuclear Information System (INIS)

    Shiomi, Takeshi; Shimizu, Tatsuya; Iinuma, Masao; Takemoto, Hajime; Tanaka, Shuji

    2003-01-01

    This report refers to the clinical applications of our newly developed SONIALVISION 100 fully digitalized X-ray diagnostic table system. The main design concept of the SONIALVISION 100 system is the improvement of workflow in various clinical fields. The development of digital imaging technologies has come to allow fully digitalized X-ray diagnostic table systems to be widely utilized in various clinical applications, including interventional radiology (IVR) and examinations using contrast medium. This report mainly refers to the clinical applications of the Shimadzu SONIALVISION 100 digitalized X-ray diagnostic table system, also presenting some typical image data demonstrating the high efficiency, made available through the use of this new system, in high-speed spot imaging and digital tomography. (author)

  17. New ultrasound stone locking system in extracorporeal lithotripsy: Decreased duration of fluoroscopy and radiation doses

    International Nuclear Information System (INIS)

    Abid, N.; Ravier, E.; Codas, R.; Crouzet, S.; Martin, X.

    2013-01-01

    Extracorporeal shock wave lithotripsy is the most common method of treatment for kidney stones. Both fluoroscopy and ultrasound imaging can be used to locate stones, but fluoroscopy is more frequently employed. Evaluation of a new stereotaxic navigational system: the stone was located using an ultrasound probe, and its 3D location was saved. The table automatically moved to position the stone at the focal point. A real-time follow-up was possible during treatment. Our objective was to demonstrate a decrease in the use of fluoroscopy to locate kidney stones for extracorporeal shock wave lithotripsy through the use of a 3D ultrasound stone locking system. Prospective analysis of the case records of the 20 patients preceding and the 20 patients succeeding the arrival of the ultrasound stone locking system Visio-Track (EDAP-TMS). We used a Student test to compare age, BMI, kidney stone size, number of shock waves and administered energy. Patient characteristics were comparable. The average age was 55 years old and the average kidney stone size was 10.7 mm. Radiation duration was 174.8 seconds in the group without Visio-Track versus 57.1 seconds in the group with it (P < 0.0001). A similar result was observed for radiation doses: 5197.25 mGy.cm 2 for the group without versus 1987.6 mGy.cm 2 for the group with Visio-Track (P ≡ 0.0033). The stone locking system Visio-Track reduced fluoroscopy in our first group of patients, which decreased the patient's individual absorbed irradiation dose. (authors)

  18. Transverse vs torsional ultrasound: prospective randomized contralaterally controlled study comparing two phacoemulsification-system handpieces.

    Science.gov (United States)

    Assil, Kerry K; Harris, Lindsay; Cecka, Jeannie

    2015-01-01

    To compare surgical efficiency and multiple early clinical outcome variables in eyes undergoing phacoemulsification using either transversal or torsional ultrasound systems. Assil Eye Institute, Beverly Hills, CA, USA. Prospective, randomized, clinician-masked, contralaterally controlled single-center evaluation. Patients seeking cataract removal in both eyes with implantation of multifocal intraocular lenses were randomly assigned to one of two treatment rooms for phacoemulsification with either a transverse ultrasound system or torsional handpiece system. The contralateral eye was treated at a later date with the alternate device. A total of 54 eyes of 27 patients having similar degrees of cataract, astigmatism, and visual potential were included. All operative data were collected for analysis, and patients were followed for 3 months after surgery. Similar visual acuity was reported at all postoperative visits between the two groups. Mean phacoemulsification time and total power required were both significantly lower with the transverse system than with the torsional technique (Ptransverse system vs torsional (Ptransverse vs torsional. Macular swelling was less at 1 week, 1 month, and 3 months with transverse vs torsional, although the difference did not achieve significance (P=0.1) at any single time point. Clinically detectable corneal edema was reported less frequently at all postoperative time points with the transverse system. The transverse ultrasound system was found to be possibly associated with less balanced salt-solution use, less phacoemulsification time, and less power required than the torsional phaco system. Postoperative data suggested that improved phaco efficiency may translate to a better overall safety profile for the patient.

  19. A Methodology for Anatomic Ultrasound Image Diagnostic Quality Assessment

    DEFF Research Database (Denmark)

    Hemmsen, Martin Christian; Lange, Theis; Brandt, Andreas Hjelm

    2017-01-01

    are presented. Earlier uses of the methodology has shown that it ensures validity of the assessment, as it separates the influences between developer, investigator, and assessor once a research protocol has been established. This separation reduces confounding influences on the result from the developer......This paper discusses methods for assessment of ultrasound image quality based on our experiences with evaluating new methods for anatomic imaging. It presents a methodology to ensure a fair assessment between competing imaging methods using clinically relevant evaluations. The methodology...... to properly reveal the clinical value. The paper exemplifies the methodology using recent studies of Synthetic Aperture Sequential Beamforming tissue harmonic imaging....

  20. A thermocouple thermometry system for ultrasound hyperthermia

    International Nuclear Information System (INIS)

    Ozarka, M.; Gharakhani, A.; Magin, R.; Cain, C.

    1984-01-01

    A thermometry system designed to be used in the treatment of cancer by ultrasound hyperthermia is described. The system monitors tumor temperatures using 16 type T (copper-constantan) thermocouples and is controlled by a 12 MHz Intel 8031 microcomputer. An analog circuit board contains the thermocouple amplifiers, an analog multiplexer, scaling circuitry, and an analog to digital converter. A digital board contains the Intel 8031, program memory, data memory, as well as circuitry for control and data communications. Communication with the hyperthermia system control computer is serially by RS-232 with selectable baud rate. Since the thermocouple amplifiers may have slight differences in gain and offset, a calibrated offset is added to a lookup table value to obtain the proper display temperature to within +- 0.1 0 C. The calibration routine, implemented in software, loads a nonvolatile random access memory chip with the proper offset values based on the outputs of each thermocouple channel at known temperatures which bracket a range of interest