WorldWideScience

Sample records for diagnostic tests achieve

  1. Auditory Automotive Mechanics Diagnostic Achievement Test. Center Technical Paper No. 2.

    Science.gov (United States)

    Swanson, Richard Arthur

    The Auditory Automotive Mechanics Diagnostic Achievement Test assesses an automobile mechanic's ability to determine mechanical faults from auditory cues alone. The 44-item test and its instructions are recorded on magnetic tape; answer choices are presented on tape, and are also written in the printed test booklets. The norming and validity…

  2. Quality Control in Diagnostic Radiology: Experiences and Achievements

    International Nuclear Information System (INIS)

    Mohd Khalid Matori; Husaini Salleh; Muhammad Jamal Md Isa

    2015-01-01

    Malaysian Nuclear Agency through its Medical Physics Group has been providing Quality Control (QC) services for medical X-ray apparatus used in diagnostic radiology to private clinics and hospitals since the year 1997. The Medical Physics Groups services is endorsed by the Malaysian Ministry Of Health (MOH) and is in accordance with the Malaysian Standard MS 838 and the Atomic Energy Licensing Act, 1984. Until today, the scopes of testing services also include all types of medical x-ray apparatus. The quality control (QC) in diagnostic radiology is considered as part of quality assurance program which provide accurate diagnostic information at the lowest cost and the least exposure of the patients to radiation. Many experience and obstacles were faced by Medical Physics Group. This paper will discuss the experiences and achievements of providing QC service from early stage until now so that it can be shared by the citizens of the Malaysian Nuclear Agency. The results of quality assurance inspection of all types of X-ray apparatus for medical conducted by Agency Nuclear Malaysia will be presented in brief. (author)

  3. Better Tests, Better Care: Improved Diagnostics for Infectious Diseases

    Science.gov (United States)

    Caliendo, Angela M.; Gilbert, David N.; Ginocchio, Christine C.; Hanson, Kimberly E.; May, Larissa; Quinn, Thomas C.; Tenover, Fred C.; Alland, David; Blaschke, Anne J.; Bonomo, Robert A.; Carroll, Karen C.; Ferraro, Mary Jane; Hirschhorn, Lisa R.; Joseph, W. Patrick; Karchmer, Tobi; MacIntyre, Ann T.; Reller, L. Barth; Jackson, Audrey F.

    2013-01-01

    In this IDSA policy paper, we review the current diagnostic landscape, including unmet needs and emerging technologies, and assess the challenges to the development and clinical integration of improved tests. To fulfill the promise of emerging diagnostics, IDSA presents recommendations that address a host of identified barriers. Achieving these goals will require the engagement and coordination of a number of stakeholders, including Congress, funding and regulatory bodies, public health agencies, the diagnostics industry, healthcare systems, professional societies, and individual clinicians. PMID:24200831

  4. Optimal Combinations of Diagnostic Tests Based on AUC.

    Science.gov (United States)

    Huang, Xin; Qin, Gengsheng; Fang, Yixin

    2011-06-01

    When several diagnostic tests are available, one can combine them to achieve better diagnostic accuracy. This article considers the optimal linear combination that maximizes the area under the receiver operating characteristic curve (AUC); the estimates of the combination's coefficients can be obtained via a nonparametric procedure. However, for estimating the AUC associated with the estimated coefficients, the apparent estimation by re-substitution is too optimistic. To adjust for the upward bias, several methods are proposed. Among them the cross-validation approach is especially advocated, and an approximated cross-validation is developed to reduce the computational cost. Furthermore, these proposed methods can be applied for variable selection to select important diagnostic tests. The proposed methods are examined through simulation studies and applications to three real examples. © 2010, The International Biometric Society.

  5. 42 CFR 410.32 - Diagnostic x-ray tests, diagnostic laboratory tests, and other diagnostic tests: Conditions.

    Science.gov (United States)

    2010-10-01

    ... Procedural Terminology published by the American Medical Association. (3) Levels of supervision. Except where... & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES MEDICARE PROGRAM SUPPLEMENTARY MEDICAL INSURANCE (SMI) BENEFITS Medical and Other Health Services § 410.32 Diagnostic x-ray tests, diagnostic laboratory...

  6. Beyond Diagnostic Accuracy: The Clinical Utility of Diagnostic Tests

    NARCIS (Netherlands)

    Bossuyt, Patrick M. M.; Reitsma, Johannes B.; Linnet, Kristian; Moons, Karel G. M.

    2012-01-01

    Like any other medical technology or intervention, diagnostic tests should be thoroughly evaluated before their introduction into daily practice. Increasingly, decision makers, physicians, and other users of diagnostic tests request more than simple measures of a test's analytical or technical

  7. Whole Genome Sequencing Increases Molecular Diagnostic Yield Compared with Current Diagnostic Testing for Inherited Retinal Disease.

    Science.gov (United States)

    Ellingford, Jamie M; Barton, Stephanie; Bhaskar, Sanjeev; Williams, Simon G; Sergouniotis, Panagiotis I; O'Sullivan, James; Lamb, Janine A; Perveen, Rahat; Hall, Georgina; Newman, William G; Bishop, Paul N; Roberts, Stephen A; Leach, Rick; Tearle, Rick; Bayliss, Stuart; Ramsden, Simon C; Nemeth, Andrea H; Black, Graeme C M

    2016-05-01

    To compare the efficacy of whole genome sequencing (WGS) with targeted next-generation sequencing (NGS) in the diagnosis of inherited retinal disease (IRD). Case series. A total of 562 patients diagnosed with IRD. We performed a direct comparative analysis of current molecular diagnostics with WGS. We retrospectively reviewed the findings from a diagnostic NGS DNA test for 562 patients with IRD. A subset of 46 of 562 patients (encompassing potential clinical outcomes of diagnostic analysis) also underwent WGS, and we compared mutation detection rates and molecular diagnostic yields. In addition, we compared the sensitivity and specificity of the 2 techniques to identify known single nucleotide variants (SNVs) using 6 control samples with publically available genotype data. Diagnostic yield of genomic testing. Across known disease-causing genes, targeted NGS and WGS achieved similar levels of sensitivity and specificity for SNV detection. However, WGS also identified 14 clinically relevant genetic variants through WGS that had not been identified by NGS diagnostic testing for the 46 individuals with IRD. These variants included large deletions and variants in noncoding regions of the genome. Identification of these variants confirmed a molecular diagnosis of IRD for 11 of the 33 individuals referred for WGS who had not obtained a molecular diagnosis through targeted NGS testing. Weighted estimates, accounting for population structure, suggest that WGS methods could result in an overall 29% (95% confidence interval, 15-45) uplift in diagnostic yield. We show that WGS methods can detect disease-causing genetic variants missed by current NGS diagnostic methodologies for IRD and thereby demonstrate the clinical utility and additional value of WGS. Copyright © 2016 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  8. Non-Destructive Testing for Building Diagnostics and Monitoring: Experience Achieved with Case Studies

    Directory of Open Access Journals (Sweden)

    Tavukçuoğlu Ayşe

    2018-01-01

    Full Text Available Building inspection on site, in other words in-situ examinations of buildings is a troublesome work that necessitates the use of non-destructive investigation (NDT techniques. One of the main concerns of non-destructive testing studies is to improve in-situ use of NDT techniques for diagnostic and monitoring studies. The quantitative infrared thermography (QIRT and ultrasonic pulse velocity (UPV measurements have distinct importance in that regard. The joint use of QIRT and ultrasonic testing allows in-situ evaluation and monitoring of historical structures and contemporary ones in relation to moisture, thermal, materials and structural failures while the buildings themselves remain intact. For instances, those methods are useful for detection of visible and invisible cracks, thermal bridges and damp zones in building materials, components and functional systems as well as for soundness assessment of materials and thermal performance assessment of building components. In addition, those methods are promising for moisture content analyses in materials and monitoring the success of conservation treatments or interventions in structures. The in-situ NDT studies for diagnostic purposes should start with the mapping of decay forms and scanning of building surfaces with infrared images. Quantitative analyses are shaped for data acquisition on site and at laboratory from representative sound and problem areas in structures or laboratory samples. Laboratory analyses are needed to support in-situ examinations and to establish the reference data for better interpretation of in situ data. Advances in laboratory tests using IRT and ultrasonic testing are guiding for in-situ materials investigations based on measurable parameters. The knowledge and experience on QIRT and ultrasonic testing are promising for the innovative studies on today’s materials technologies, building science and conservation/maintenance practices. Such studies demand a multi

  9. Effects of Concept Map Extraction and a Test-Based Diagnostic Environment on Learning Achievement and Learners' Perceptions

    Science.gov (United States)

    Lin, Yu-Shih; Chang, Yi-Chun; Liew, Keng-Hou; Chu, Chih-Ping

    2016-01-01

    Computerised testing and diagnostics are critical challenges within an e-learning environment, where the learners can assess their learning performance through tests. However, a test result based on only a single score is insufficient information to provide a full picture of learning performance. In addition, because test results implicitly…

  10. Comparing diagnostic tests on benefit-risk.

    Science.gov (United States)

    Pennello, Gene; Pantoja-Galicia, Norberto; Evans, Scott

    2016-01-01

    Comparing diagnostic tests on accuracy alone can be inconclusive. For example, a test may have better sensitivity than another test yet worse specificity. Comparing tests on benefit risk may be more conclusive because clinical consequences of diagnostic error are considered. For benefit-risk evaluation, we propose diagnostic yield, the expected distribution of subjects with true positive, false positive, true negative, and false negative test results in a hypothetical population. We construct a table of diagnostic yield that includes the number of false positive subjects experiencing adverse consequences from unnecessary work-up. We then develop a decision theory for evaluating tests. The theory provides additional interpretation to quantities in the diagnostic yield table. It also indicates that the expected utility of a test relative to a perfect test is a weighted accuracy measure, the average of sensitivity and specificity weighted for prevalence and relative importance of false positive and false negative testing errors, also interpretable as the cost-benefit ratio of treating non-diseased and diseased subjects. We propose plots of diagnostic yield, weighted accuracy, and relative net benefit of tests as functions of prevalence or cost-benefit ratio. Concepts are illustrated with hypothetical screening tests for colorectal cancer with test positive subjects being referred to colonoscopy.

  11. How to appraise a diagnostic test

    Directory of Open Access Journals (Sweden)

    Ramanitharan Manikandan

    2011-01-01

    Full Text Available Urologists frequently encounter problems in making a clinical diagnosis whose resolution requires the use of diagnostic tests. With an ever increasing choice of investigations being available, the urologist often has to decide which diagnostic test(s will best resolve the patient′s diagnostic problem. In this article, we aim to help the urologist understand how to critically appraise studies on diagnostic tests and make a rational choice. This article presents the guiding principles in scientifically assessing studies on diagnostic tests by proposing a clinical scenario. The authors describe a standardized protocol to assess the validity of the test and its relevance to the clinical problem that can help the urologist in decision making. The three important issues to be considered when evaluating the validity of the study are to identify how the study population was chosen, how the test was performed and whether there is a comparison to the gold standard test so as to confirm or refute the diagnosis. Then, the urologist would need to know the probability of the test in providing the correct diagnosis in an individual patient in order to decide about its utility in solving the diagnostic dilemma. By performing the steps described in this article, the urologist would be able to critically appraise diagnostic studies and draw meaningful conclusions about the investigations in terms of validity, results and its applicability to the patient′s problem. This would provide a scientific basis for using diagnostic tests for improving patient care.

  12. 1968 Prototype Diagnostic Test.

    Science.gov (United States)

    Veterans Administration Hospital, Bedford, MA.

    This true-false diagnostic test was used for pretesting of employees at a Veterans Administration Hospital. The test is comprised of 20 items. An alternate test--Classification Questionnaire--was used for testing after remedial training. (For related document, see TM 002 334.) (DB)

  13. Myasthenia Gravis: Tests and Diagnostic Methods

    Science.gov (United States)

    ... Focus on MG Newsletter MG Quarterly Test & Diagnostic methods In addition to a complete medical and neurological ... How can I help? About MGFA Test & Diagnostic methods Treatment for MG FAQ's Upcoming Events 2018 MG ...

  14. Diagnosis of asthma: diagnostic testing.

    Science.gov (United States)

    Brigham, Emily P; West, Natalie E

    2015-09-01

    Asthma is a heterogeneous disease, encompassing both atopic and non-atopic phenotypes. Diagnosis of asthma is based on the combined presence of typical symptoms and objective tests of lung function. Objective diagnostic testing consists of 2 components: (1) demonstration of airway obstruction, and (2) documentation of variability in degree of obstruction. A review of current guidelines and literature was performed regarding diagnostic testing for asthma. Spirometry with bronchodilator reversibility testing remains the mainstay of asthma diagnostic testing for children and adults. Repetition of the test over several time points may be necessary to confirm airway obstruction and variability thereof. Repeated peak flow measurement is relatively simple to implement in a clinical and home setting. Bronchial challenge testing is reserved for patients in whom the aforementioned testing has been unrevealing but clinical suspicion remains, though is associated with low specificity. Demonstration of eosinophilic inflammation, via fractional exhaled nitric oxide measurement, or atopy, may be supportive of atopic asthma, though diagnostic utility is limited particularly in nonatopic asthma. All efforts should be made to confirm the diagnosis of asthma in those who are being presumptively treated but have not had objective measurements of variability in the degree of obstruction. Multiple testing modalities are available for objective confirmation of airway obstruction and variability thereof, consistent with a diagnosis of asthma in the appropriate clinical context. Providers should be aware that both these characteristics may be present in other disease states, and may not be specific to a diagnosis of asthma. © 2015 ARS-AAOA, LLC.

  15. Decision analysis to complete diagnostic research by closing the gap between test characteristics and cost-effectiveness.

    Science.gov (United States)

    Schaafsma, Joanna D; van der Graaf, Yolanda; Rinkel, Gabriel J E; Buskens, Erik

    2009-12-01

    The lack of a standard methodology in diagnostic research impedes adequate evaluation before implementation of constantly developing diagnostic techniques. We discuss the methodology of diagnostic research and underscore the relevance of decision analysis in the process of evaluation of diagnostic tests. Overview and conceptual discussion. Diagnostic research requires a stepwise approach comprising assessment of test characteristics followed by evaluation of added value, clinical outcome, and cost-effectiveness. These multiple goals are generally incompatible with a randomized design. Decision-analytic models provide an important alternative through integration of the best available evidence. Thus, critical assessment of clinical value and efficient use of resources can be achieved. Decision-analytic models should be considered part of the standard methodology in diagnostic research. They can serve as a valid alternative to diagnostic randomized clinical trials (RCTs).

  16. Methodology of diagnostic tests in hepatology

    DEFF Research Database (Denmark)

    Christensen, Erik

    2009-01-01

    The performance of diagnostic tests can be assessed by a number of methods. These include sensitivity, specificity,positive and negative predictive values, likelihood ratios and receiver operating characteristic (ROC) curves. This paper describes the methods and explains which information...... they provide. Sensitivity and specificity provides measures of the diagnostic accuracy of a test in diagnosing the condition. The positive and negative predictive values estimate the probability of the condition from the test-outcome and the condition's prevalence. The likelihood ratios bring together......' and plotting sensitivity as a function of 1-specificity. The ROC-curve can be used to define optimal cut-off values for a test, to assess the diagnostic accuracy of the test, and to compare the usefulness of different tests in the same patients. Under certain conditions it may be possible to utilize a test...

  17. Real-Time Remote Diagnostic Monitoring Test-bed in JET

    Energy Technology Data Exchange (ETDEWEB)

    Castro, R. [Asociation Euratom/CIEMAT para Fusion, Madrid (Spain); Kneupner, K.; Purahoo, K. [EURATOM/UKAEA Fusion Association, Abingdon (United Kingdom); Vega, J.; Pereira, A.; Portas, A. [Association EuratomCIEMAT para Fusion, Madrid (Spain); De Arcas, G.; Lopez, J.M. [Universidad Politecnica de Madrid (Spain); Murari, A. [Consorzio RFX, Padova (Italy); Fonseca, A. [Associacao URATOM/IST, Lisboa (Portugal); Contributors, J.E. [JET-EFDA, Abingdon (United Kingdom)

    2009-07-01

    Based on the remote experimentation concept oriented to long pulse shots, a test-bed system has been implemented in JET. It integrates 2 functionalities. The first one is the real-time monitoring, on remote, of a reflectometer diagnostic, to visualize different data outputs and status information. The second one is the integration of dotJET (Diagnostic Overview Tool for JET), which internally provides at JET an overview about the current diagnostic systems state, in order to monitor, on remote, JET diagnostics status. The architecture of the system is formed by: the data generator components, the data distribution system, an access control service, and the client applications. In the test-bed there are two data generators: the acquisition equipment associated with the reflectometer diagnostic that generates data and status information, and dotJET server that centralize the access to the status information of JET diagnostics. The data distribution system has been implemented using a publishing-subscribing technology that receives data from data generators and redistributes them to client applications. And finally, for monitoring, a client application based on Java Web Start technology, and a dotJET client application have been used. There are 3 interesting results from this project. The first one is the analysis of different aspects (data formats, data frame rate, data resolution, etc) related with remote real-time diagnostic monitoring oriented to long pulse experiments. The second one is the definition and implementation of a flexible enough architecture, to be applied to different types of data generated from other diagnostics, and that fits with remote access requirements; and the third one is to have achieved a secure system, taking into account internal networks and firewalls aspects in JET, and securing the access from remote users. For this last issue, PAPI technology has been used, enabling access control based on user attributes, enabling mobile users to

  18. The interpretation of diagnostic tests

    International Nuclear Information System (INIS)

    Lamk, M.; Lamki, M.D.

    1987-01-01

    The progress of nuclear and other diagnostic imaging is near rampant. With almost every issue of the major journals in this field, a new diagnostic test, or at least a new utility of an old test is described. Before we accept these innovations, we have to have a clear understanding of the clinical performance of the test. The major criteria are the sensitivity and the specificity of the test. From these derived other statistical parameters such as accuracy or efficiency of that test; also, the receiver operating characteristic (ROC) curves may then be evaluated and used in comparison of different tests. When we know the prevalence of the disease tested in the population we are investigating, we can then derive the predictive value of a positive or a negative result. This introduction tries to explain these parameters to help the reader understand the literature dealing with the subject of efficacy of imaging procedures. It is not intended as a critical review of the literature on the subject or a comprehensive overview of the subject matter. The benefit derived from explaination of statistical concepts to physicians is documented in a recent publication. Explaination of these basic statistical parameters will be followed by a demonstration of the utility of multiple testing with these parameters. The reader is thereby introduced to relevant statistical concepts that must be grasped for full comprehension of published results of a new diagnostic imaging modality, or before clinical decision making

  19. Diagnostic tests based on human basophils

    DEFF Research Database (Denmark)

    Kleine-Tebbe, Jörg; Erdmann, Stephan; Knol, Edward F

    2006-01-01

    -maximal responses, termed 'intrinsic sensitivity'. These variables give rise to shifts in the dose-response curves which, in a diagnostic setting where only a single antigen concentration is employed, may produce false-negative data. Thus, in order to meaningfully utilize the current basophil activation tests....... Diagnostic studies using CD63 or CD203c in hymenoptera, food and drug allergy are critically discussed. Basophil-based tests are indicated for allergy testing in selected cases but should only be performed by experienced laboratories....

  20. Prenatal Genetic Diagnostic Tests

    Science.gov (United States)

    ... are available for many inherited disorders. The main disadvantage is that diagnostic testing carries a very small ... chromosomes, arranged in order of size. Microarray: A technology that examines all of a person’s genes to ...

  1. Diagnostic significance of haematological testing in patients presenting at the Emergency Department

    Directory of Open Access Journals (Sweden)

    Giuseppe Lippi

    2012-03-01

    Full Text Available The use of simple and economic tests to rule out diseases of sufficient clinical severity is appealing in emergency department (ED, since it would be effective for contrasting ED overcrowding and decreasing healthcare costs. The aim of this study was to assess the diagnostic performance of simple and economic haematological testing in a large sample of adult patients presenting at the ED of the Academic Hospital of Parma during the year 2010 with the five most frequent acute pathologies (i.e., acute myocardial infarction, renal colic, pneumonia, trauma and pancreatitis. Both leukocyte count and hemoglobin showed a good diagnostic performance (Area Under the Curve [AUC] of 0.85 for leukocyte count and 0.76 for hemoglobin; both p < 0.01. Although the platelet count was significantly increased in all patients groups except pancreatitis, the diagnostic performance did not achieve statistical significance (AUC 0.53; p = 0.07. We also observed an increased RDW in all groups, except in those with trauma and the diagnostic performance was acceptable (AUC 0.705; p < 0.01. The mean platelet volume (MPV was consistently lower in all patients groups and also characterized by an efficient diagnostic performance (AUC 0.76; p < 0.01. This evidence led us to design an arbitrary formula, whereby MPV and hemoglobin were multiplied, and further divided by the leukocyte count, obtaining a remarkable AUC (0.91; p < 0.01. We conclude that simple, rapid and cheap hematological tests might provide relevant clinical information for decision making to busy emergency physicians, and the their combination into an arbitrary formula might further increase the specific diagnostic potential of each of them.

  2. Evaluating Diagnostic Point-of-Care Tests in Resource-Limited Settings

    Science.gov (United States)

    Drain, Paul K; Hyle, Emily P; Noubary, Farzad; Freedberg, Kenneth A; Wilson, Douglas; Bishai, William; Rodriguez, William; Bassett, Ingrid V

    2014-01-01

    Diagnostic point-of-care (POC) testing is intended to minimize the time to obtain a test result, thereby allowing clinicians and patients to make an expeditious clinical decision. As POC tests expand into resource-limited settings (RLS), the benefits must outweigh the costs. To optimize POC testing in RLS, diagnostic POC tests need rigorous evaluations focused on relevant clinical outcomes and operational costs, which differ from evaluations of conventional diagnostic tests. Here, we reviewed published studies on POC testing in RLS, and found no clearly defined metric for the clinical utility of POC testing. Therefore, we propose a framework for evaluating POC tests, and suggest and define the term “test efficacy” to describe a diagnostic test’s capacity to support a clinical decision within its operational context. We also proposed revised criteria for an ideal diagnostic POC test in resource-limited settings. Through systematic evaluations, comparisons between centralized diagnostic testing and novel POC technologies can be more formalized, and health officials can better determine which POC technologies represent valuable additions to their clinical programs. PMID:24332389

  3. Diagnostic x-ray equipment compliance and facility survey. Recommended procedures for equipment and facility testing

    International Nuclear Information System (INIS)

    1994-01-01

    The Radiation Protection Bureau has set out guidelines for the testing of diagnostic x-ray equipment and facilities. This guide provides information for the x-ray inspector, test engineer, technologist, medical physicist and any other person responsible for verifying the regulatory compliance or safety of diagnostic x-ray equipment and facilities. Diagnostic x-radiation is an essential part of present day medical practice. The largest contributor of irradiation to the general population comes from diagnostic x-radiation. Although individual irradiations are usually small, there is a concern of possible excess cancer risk when large populations are irradiated. Unnecessary irradiations to patients from radiological procedures can be significantly reduced with little or no decrease in the value of medical diagnostic information. This can be achieved by using well designed x-ray equipment which is installed, used and maintained by trained personnel, and by the adoption of standardized procedures. In general, when patient surface dose is reduced, there is a corresponding decrease in dose to x-ray equipment operators and other health care personnel. 2 tabs., 4 figs

  4. Diagnostic x-ray equipment compliance and facility survey. Recommended procedures for equipment and facility testing

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1994-12-31

    The Radiation Protection Bureau has set out guidelines for the testing of diagnostic x-ray equipment and facilities. This guide provides information for the x-ray inspector, test engineer, technologist, medical physicist and any other person responsible for verifying the regulatory compliance or safety of diagnostic x-ray equipment and facilities. Diagnostic x-radiation is an essential part of present day medical practice. The largest contributor of irradiation to the general population comes from diagnostic x-radiation. Although individual irradiations are usually small, there is a concern of possible excess cancer risk when large populations are irradiated. Unnecessary irradiations to patients from radiological procedures can be significantly reduced with little or no decrease in the value of medical diagnostic information. This can be achieved by using well designed x-ray equipment which is installed, used and maintained by trained personnel, and by the adoption of standardized procedures. In general, when patient surface dose is reduced, there is a corresponding decrease in dose to x-ray equipment operators and other health care personnel. 2 tabs., 4 figs.

  5. [Diagnostic test scale SI5: Assessment of sacroiliac joint dysfunction].

    Science.gov (United States)

    Acevedo González, Juan C; Quintero Oliveros, Silvia

    2015-01-01

    Sacroiliac joint dysfunction is a known cause of low back pain. We think that a diagnostic score scale (SI5) may be performed to assess diagnostic utility of clinical signs of sacroiliac joint dysfunction. The primary aim of the present study was to conduct the pilot study of our new diagnostic score scale, the SI5, for sacroiliac joint syndrome. We reviewed the literature on clinical characteristics, diagnostic tests and imaging most commonly used in diagnosing sacroiliac joint dysfunction. Our group evaluated the diagnostic utility of these aspects and we used those considered most representative to develop the SI5 diagnostic scale. The SI5 scale was applied to 22 patients with low back pain; afterwards, the standard test for diagnosing this pathology (selective blockage of the SI joint) was also performed on these patients. The sensitivity and specificity for each sign were also assessed and the diagnostic scale called SI5 was then proposed, based on these data. The most sensitive clinical tests for diagnosing SI joint dysfunction were 2 patient-reported clinical characteristics, the Laguerre Test, sacroiliac rocking test and Yeomans test (greater than 80% sensitivity). The tests with greatest diagnostic specificity (>80%) were the Lewitt test, Piedallu test and Gillet test. The proposed SI5 test score scale showed sensitivity of 73% and specificity of 71%. Sacroiliac joint syndrome has been shown to produce low back pain frequently; however, the diagnostic value of examination tests for sacroiliac joint pain has been questioned by other authors. The pilot study on the SI5 diagnostic score scale showed good sensitivity and specificity. However, the process of statistical validation of the SI5 needs to be continued. Copyright © 2014 Sociedad Española de Neurocirugía. Published by Elsevier España. All rights reserved.

  6. Systematic reviews of diagnostic test accuracy

    DEFF Research Database (Denmark)

    Leeflang, Mariska M G; Deeks, Jonathan J; Gatsonis, Constantine

    2008-01-01

    More and more systematic reviews of diagnostic test accuracy studies are being published, but they can be methodologically challenging. In this paper, the authors present some of the recent developments in the methodology for conducting systematic reviews of diagnostic test accuracy studies....... Restrictive electronic search filters are discouraged, as is the use of summary quality scores. Methods for meta-analysis should take into account the paired nature of the estimates and their dependence on threshold. Authors of these reviews are advised to use the hierarchical summary receiver...

  7. Understanding the properties of diagnostic tests - Part 2: Likelihood ratios.

    Science.gov (United States)

    Ranganathan, Priya; Aggarwal, Rakesh

    2018-01-01

    Diagnostic tests are used to identify subjects with and without disease. In a previous article in this series, we examined some attributes of diagnostic tests - sensitivity, specificity, and predictive values. In this second article, we look at likelihood ratios, which are useful for the interpretation of diagnostic test results in everyday clinical practice.

  8. The indication area of a diagnostic test. Part I--discounting gain and loss in diagnostic certainty

    NARCIS (Netherlands)

    Stalpers, Lukas J. A.; Nelemans, Patty J.; Geurts, Sandra M. E.; Jansen, Erik; de Boer, Peter; Verbeek, André L. M.

    2015-01-01

    Test performance is conventionally expressed by gain in diagnostic certainty. We propose net diagnostic gain and indication area as more appropriate measures of test performance; then, the loss in certainty due to misclassification and the information of "no test" would be performed are taken into

  9. Antimicrobial susceptibility testing by Australian veterinary diagnostic laboratories.

    Science.gov (United States)

    Hardefeldt, L Y; Marenda, M; Crabb, H; Stevenson, M A; Gilkerson, J R; Billman-Jacobe, H; Browning, G F

    2018-04-01

    The national strategy for tackling antimicrobial resistance highlights the need for antimicrobial stewardship in veterinary practice and for surveillance of antimicrobial susceptibility in veterinary pathogens. Diagnostic laboratories have an important role in facilitating both of these processes, but it is unclear whether data from veterinary diagnostic laboratories are similar enough to allow for compilation and if there is consistent promotion of appropriate antimicrobial use embedded in the approaches of different laboratories to susceptibility testing. A cross-sectional study of antimicrobial susceptibility testing and reporting procedures by Australian veterinary diagnostic laboratories was conducted in 2017 using an online questionnaire. All 18 veterinary diagnostic laboratories in Australia completed the questionnaire. Kirby-Bauer disc diffusion was the method predominantly used for antimicrobial susceptibility testing and was used to evaluate 86% of all isolates, although two different protocols were used across the 18 laboratories (CLSI 15/18, CDS 3/18). Minimum inhibitory concentrations were never reported by 61% of laboratories. Common isolates were consistently reported on across all species, except for gram-negative isolates in pigs, for which there was some variation in the approach to reporting. There was considerable diversity in the panels of antimicrobials used for susceptibility testing on common isolates and no consistency was apparent between laboratories for any bacterial species. We recommend that nationally agreed and consistent antimicrobial panels for routine susceptibility testing should be developed and a uniform set of guidelines should be adopted by veterinary diagnostic laboratories in Australia. © 2018 Australian Veterinary Association.

  10. The impact of new trends in POCTs for companion diagnostics, non-invasive testing and molecular diagnostics.

    Science.gov (United States)

    Huckle, David

    2015-06-01

    Point-of-care diagnostics have been slowly developing over several decades and have taken on a new importance in current healthcare delivery for both diagnostics and development of new drugs. Molecular diagnostics have become a key driver of technology change and opened up new areas in companion diagnostics for use alongside pharmaceuticals and in new clinical approaches such as non-invasive testing. Future areas involving smartphone and other information technology advances, together with new developments in molecular biology, microfluidics and surface chemistry are adding to advances in the market. The focus for point-of-care tests with molecular diagnostic technologies is focused on advancing effective applications.

  11. Immunochromatographic diagnostic test analysis using Google Glass.

    Science.gov (United States)

    Feng, Steve; Caire, Romain; Cortazar, Bingen; Turan, Mehmet; Wong, Andrew; Ozcan, Aydogan

    2014-03-25

    We demonstrate a Google Glass-based rapid diagnostic test (RDT) reader platform capable of qualitative and quantitative measurements of various lateral flow immunochromatographic assays and similar biomedical diagnostics tests. Using a custom-written Glass application and without any external hardware attachments, one or more RDTs labeled with Quick Response (QR) code identifiers are simultaneously imaged using the built-in camera of the Google Glass that is based on a hands-free and voice-controlled interface and digitally transmitted to a server for digital processing. The acquired JPEG images are automatically processed to locate all the RDTs and, for each RDT, to produce a quantitative diagnostic result, which is returned to the Google Glass (i.e., the user) and also stored on a central server along with the RDT image, QR code, and other related information (e.g., demographic data). The same server also provides a dynamic spatiotemporal map and real-time statistics for uploaded RDT results accessible through Internet browsers. We tested this Google Glass-based diagnostic platform using qualitative (i.e., yes/no) human immunodeficiency virus (HIV) and quantitative prostate-specific antigen (PSA) tests. For the quantitative RDTs, we measured activated tests at various concentrations ranging from 0 to 200 ng/mL for free and total PSA. This wearable RDT reader platform running on Google Glass combines a hands-free sensing and image capture interface with powerful servers running our custom image processing codes, and it can be quite useful for real-time spatiotemporal tracking of various diseases and personal medical conditions, providing a valuable tool for epidemiology and mobile health.

  12. Dilution testing using rapid diagnostic tests in a HIV diagnostic algorithm: a novel alternative for confirmation testing in resource limited settings.

    Science.gov (United States)

    Shanks, Leslie; Siddiqui, M Ruby; Abebe, Almaz; Piriou, Erwan; Pearce, Neil; Ariti, Cono; Masiga, Johnson; Muluneh, Libsework; Wazome, Joseph; Ritmeijer, Koert; Klarkowski, Derryck

    2015-05-14

    Current WHO testing guidelines for resource limited settings diagnose HIV on the basis of screening tests without a confirmation test due to cost constraints. This leads to a potential risk of false positive HIV diagnosis. In this paper, we evaluate the dilution test, a novel method for confirmation testing, which is simple, rapid, and low cost. The principle of the dilution test is to alter the sensitivity of a rapid diagnostic test (RDT) by dilution of the sample, in order to screen out the cross reacting antibodies responsible for falsely positive RDT results. Participants were recruited from two testing centres in Ethiopia where a tiebreaker algorithm using 3 different RDTs in series is used to diagnose HIV. All samples positive on the initial screening RDT and every 10th negative sample underwent testing with the gold standard and dilution test. Dilution testing was performed using Determine™ rapid diagnostic test at 6 different dilutions. Results were compared to the gold standard of Western Blot; where Western Blot was indeterminate, PCR testing determined the final result. 2895 samples were recruited to the study. 247 were positive for a prevalence of 8.5 % (247/2895). A total of 495 samples underwent dilution testing. The RDT diagnostic algorithm misclassified 18 samples as positive. Dilution at the level of 1/160 was able to correctly identify all these 18 false positives, but at a cost of a single false negative result (sensitivity 99.6 %, 95 % CI 97.8-100; specificity 100 %, 95 % CI: 98.5-100). Concordance between the gold standard and the 1/160 dilution strength was 99.8 %. This study provides proof of concept for a new, low cost method of confirming HIV diagnosis in resource-limited settings. It has potential for use as a supplementary test in a confirmatory algorithm, whereby double positive RDT results undergo dilution testing, with positive results confirming HIV infection. Negative results require nucleic acid testing to rule out false

  13. Quantifying the Accuracy of a Diagnostic Test or Marker

    NARCIS (Netherlands)

    Linnet, Kristian; Bossuyt, Patrick M. M.; Moons, Karel G. M.; Reitsma, Johannes B. R.

    2012-01-01

    BACKGROUND: In recent years, increasing focus has been directed to the methodology for evaluating (new) tests or biomarkers. A key step in the evaluation of a diagnostic test is the investigation into its accuracy. CONTENT: We reviewed the literature on how to assess the accuracy of diagnostic

  14. Applications of optical fibers in nuclear test diagnostics

    International Nuclear Information System (INIS)

    Lyons, P.B.; Hodson, E.K.; Looney, L.D.

    1980-01-01

    Two new plasma diagnostic experiments have been successfully fielded on nuclear device tests at NTS. Both systems rely on the unique advantages provided by optical fiber technology and both systems provide new diagnostic capabilities that previously were beyond the state-of-the-art in coaxial cable systems. One system addresses the need to record e wide bandwidth data on gamma-ray sources. Over the long (< 1 km) distances that characterize NTS testing, the bandwidth of coaxial cable systems is usually limited to < 200 to 400 MHz even with extensive equalization. The new system uses the Cerenkov process to generate light in a converter material. High bandwidth fibers and detectors are used to approach a 1-GHz bandwidth. In this case fibers provided the bandwidth capability. The second system provides time and space resolution of a neutron source on a fast (ns) time scale. Previous systems have utilized either an array of neutron detectors with individual coaxial cables or a fast scintillator viewed by a gated image intensifier. For a large number of channels, the coaxial system becomes very costly and is subject to potentially severe EMI concerns. The gated intensifier system requires complex electronics and accurate timing and can be affected by EMI. An alternative system is described which provides continuous time coverage with limited spatial resolution. Complete freedom from EMI is achieved through the use of optical data collection and transmission. The optical fibers offered a major (2 to 3 times) cost savings and a large weight savings relative to the coax system. Each system is discussed

  15. Local Sensitivity and Diagnostic Tests

    NARCIS (Netherlands)

    Magnus, J.R.; Vasnev, A.L.

    2004-01-01

    In this paper we confront sensitivity analysis with diagnostic testing.Every model is misspecified, but a model is useful if the parameters of interest (the focus) are not sensitive to small perturbations in the underlying assumptions. The study of the e ect of these violations on the focus is

  16. DiagTest3Grp: An R Package for Analyzing Diagnostic Tests with Three Ordinal Groups

    Directory of Open Access Journals (Sweden)

    Jingqin Luo

    2012-10-01

    Full Text Available Medical researchers endeavor to identify potentially useful biomarkers to develop marker-based screening assays for disease diagnosis and prevention. Useful summary measures which properly evaluate the discriminative ability of diagnostic markers are critical for this purpose. Literature and existing software, for example, R packages nicely cover summary measures for diagnostic markers used for the binary case (e.g., healthy vs. diseased. An intermediate population at an early disease stage usually exists between the healthy and the fully diseased population in many disease processes. Supporting utilities for three-group diagnostic tests are highly desired and important for identifying patients at the early disease stage for timely treatments. However, application packages which provide summary measures for three ordinal groups are currently lacking. This paper focuses on two summary measures of diagnostic accuracy—volume under the receiver operating characteristic surface and the extended Youden index, with three diagnostic groups. We provide the R package DiagTest3Grp to estimate, under both parametric and nonparametric assumptions, the two summary measures and the associated variances, as well as the optimal cut-points for disease diagnosis. An omnibus test for multiple markers and a Wald test for two markers, on independent or paired samples, are incorporated to compare diagnostic accuracy across biomarkers. Sample size calculation under the normality assumption can be performed in the R package to design future diagnostic studies. A real world application evaluating the diagnostic accuracy of neuropsychological markers for Alzheimer’s disease is used to guide readers through step-by-step implementation of DiagTest3Grp to demonstrate its utility.

  17. Translating microarray data for diagnostic testing in childhood leukaemia

    International Nuclear Information System (INIS)

    Hoffmann, Katrin; Firth, Martin J; Beesley, Alex H; Klerk, Nicholas H de; Kees, Ursula R

    2006-01-01

    Recent findings from microarray studies have raised the prospect of a standardized diagnostic gene expression platform to enhance accurate diagnosis and risk stratification in paediatric acute lymphoblastic leukaemia (ALL). However, the robustness as well as the format for such a diagnostic test remains to be determined. As a step towards clinical application of these findings, we have systematically analyzed a published ALL microarray data set using Robust Multi-array Analysis (RMA) and Random Forest (RF). We examined published microarray data from 104 ALL patients specimens, that represent six different subgroups defined by cytogenetic features and immunophenotypes. Using the decision-tree based supervised learning algorithm Random Forest (RF), we determined a small set of genes for optimal subgroup distinction and subsequently validated their predictive power in an independent patient cohort. We achieved very high overall ALL subgroup prediction accuracies of about 98%, and were able to verify the robustness of these genes in an independent panel of 68 specimens obtained from a different institution and processed in a different laboratory. Our study established that the selection of discriminating genes is strongly dependent on the analysis method. This may have profound implications for clinical use, particularly when the classifier is reduced to a small set of genes. We have demonstrated that as few as 26 genes yield accurate class prediction and importantly, almost 70% of these genes have not been previously identified as essential for class distinction of the six ALL subgroups. Our finding supports the feasibility of qRT-PCR technology for standardized diagnostic testing in paediatric ALL and should, in conjunction with conventional cytogenetics lead to a more accurate classification of the disease. In addition, we have demonstrated that microarray findings from one study can be confirmed in an independent study, using an entirely independent patient cohort

  18. Reporting Diagnostic Scores in Educational Testing: Temptations, Pitfalls, and Some Solutions

    Science.gov (United States)

    Sinharay, Sandip; Puhan, Gautam; Haberman, Shelby J.

    2010-01-01

    Diagnostic scores are of increasing interest in educational testing due to their potential remedial and instructional benefit. Naturally, the number of educational tests that report diagnostic scores is on the rise, as are the number of research publications on such scores. This article provides a critical evaluation of diagnostic score reporting…

  19. Automation of diagnostic genetic testing: mutation detection by cyclic minisequencing.

    Science.gov (United States)

    Alagrund, Katariina; Orpana, Arto K

    2014-01-01

    The rising role of nucleic acid testing in clinical decision making is creating a need for efficient and automated diagnostic nucleic acid test platforms. Clinical use of nucleic acid testing sets demands for shorter turnaround times (TATs), lower production costs and robust, reliable methods that can easily adopt new test panels and is able to run rare tests in random access principle. Here we present a novel home-brew laboratory automation platform for diagnostic mutation testing. This platform is based on the cyclic minisequecing (cMS) and two color near-infrared (NIR) detection. Pipetting is automated using Tecan Freedom EVO pipetting robots and all assays are performed in 384-well micro plate format. The automation platform includes a data processing system, controlling all procedures, and automated patient result reporting to the hospital information system. We have found automated cMS a reliable, inexpensive and robust method for nucleic acid testing for a wide variety of diagnostic tests. The platform is currently in clinical use for over 80 mutations or polymorphisms. Additionally to tests performed from blood samples, the system performs also epigenetic test for the methylation of the MGMT gene promoter, and companion diagnostic tests for analysis of KRAS and BRAF gene mutations from formalin fixed and paraffin embedded tumor samples. Automation of genetic test reporting is found reliable and efficient decreasing the work load of academic personnel.

  20. A web-based test of residents' skills in diagnostic radiology

    International Nuclear Information System (INIS)

    Finlay, K.; Norman, G.R.; Keane, D.R.; Stolberg, H.

    2006-01-01

    To develop an objective, Web-based tool for evaluating residents' knowledge of diagnostic radiology. We developed and tested a Web-based evaluation tool (the Diagnostic Radiology Skills Test) that consists of 3 tests, one in each of 3 domains of diagnostic radiology: chest, gastrointestinal, and musculoskeletal imaging. Each test comprises 30 cases representing a range of difficulty in the domain, including normal states, normal variants, typical cases of common diagnoses, and cases with more subtle findings. Cases are presented with a long menu of domain-specific possible diagnoses (response options), each coded for diagnostic appropriateness. Our subjects were 21 residents in postgraduate year (PGY) 2 to 5 and 11 experts in diagnostic radiology. Subjects accessed the tool via a Web site on our Web server. Residents test results were compared for reliability and validity across domain, case, and training level. In addition, results were correlated with commonly used established and objective evaluation tools. The tool demonstrated consistent monotonic improvement in performance with training level. It showed acceptable reliability in discriminating between residents at different performance levels, both within and across training levels (r = 0.53 within level and 0.69 across levels). Test results also had concurrent validity against the American College of Radiology In-Training Examination, a widely accepted objective assessment tool (r = 0.65, P < 0.01), and 2 Objective Structured Clinical Examinations (OSCEs) focusing on diagnostic skills (r = 0.78 and r 0.69, P < 0.01, respectively). Our study demonstrates the feasibility of a Web-based, standardized, objective assessment method for evaluating residents' performance. (author)

  1. Predictors of Inappropriate Use of Diagnostic Tests and Management of Bronchiolitis

    Science.gov (United States)

    Sarmiento, Lorena; Rojas-Soto, Gladys E.

    2017-01-01

    Background The aim of the present study was to determine predictors of inappropriate use of diagnostic tests and management of bronchiolitis in a population of hospitalized infants. Methods In an analytical cross-sectional study, we determined independent predictors of the inappropriate use of diagnostic tests and management of bronchiolitis in a population of hospitalized infants. We defined a composite outcome score as the main outcome variable. Results Of the 303 included patients, 216 (71.3%) experienced an inappropriate use of diagnostic tests and treatment of bronchiolitis. After controlling for potential confounders, it was found that atopic dermatitis (OR 5.30; CI 95% 1.14–24.79; p = 0.034), length of hospital stay (OR 1.48; CI 95% 1.08–2.03; p = 0.015), and the number of siblings (OR 1.92; CI 95% 1.13–3.26; p = 0.015) were independent predictors of an inappropriate use of diagnostic tests and treatment of the disease. Conclusions Inappropriate use of diagnostic tests and treatment of bronchiolitis was a highly prevalent outcome in our population of study. Participants with atopic dermatitis, a longer hospital stay, and a greater number of siblings were at increased risk for inappropriate use of diagnostic tests and management of the disease. PMID:28758127

  2. Improving prescribing practices with rapid diagnostic tests (RDTs)

    DEFF Research Database (Denmark)

    Burchett, Helen E D; Leurent, Baptiste; Baiden, Frank

    2017-01-01

    OBJECTIVES: The overuse of antimalarial drugs is widespread. Effective methods to improve prescribing practice remain unclear. We evaluated the impact of 10 interventions that introduced rapid diagnostic tests for malaria (mRDTs) on the use of tests and adherence to results in different contexts...... packages, supervision, supplies and community sensitisation. OUTCOME MEASURES: Analysis explored variation in: (1) uptake of mRDTs (% febrile patients tested); (2) provider adherence to positive mRDTs (% Plasmodium falciparum positive prescribed/given Artemisinin Combination Treatment); (3) provider...... characteristics fitted with their own priorities. Goodness of fit of mRDTs with existing consultation and diagnostic practices appeared crucial to maximising the impact of mRDTs on care, as did prior familiarity with malaria testing; adequate human resources and supplies; possible alternative treatments for m...

  3. Drug sensitivity testing platforms for gastric cancer diagnostics.

    Science.gov (United States)

    Lau, Vianne; Wong, Andrea Li-Ann; Ng, Christopher; Mok, Yingting; Lakshmanan, Manikandan; Yan, Benedict

    2016-02-01

    Gastric cancer diagnostics has traditionally been histomorphological and primarily the domain of surgical pathologists. Although there is an increasing usage of molecular and genomic techniques for clinical diagnostics, there is an emerging field of personalised drug sensitivity testing. In this review, we describe the various personalised drug sensitivity testing platforms and discuss the challenges facing clinical adoption of these assays for gastric cancer. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  4. A Comparison of Salivary Steroid Levels during Diagnostic Tests for Adrenal Insufficiency

    Directory of Open Access Journals (Sweden)

    Michaela Dušková

    2016-01-01

    Full Text Available Numerous diagnostic tests are used to evaluate the hypothalamic-pituitary-adrenal axis (HPA axis. The gold standard is still considered the insulin tolerance test (ITT, but this test has many limitations. Current guidelines therefore recommend the Synacthen test first when an HPA axis insufficiency is suspected. However, the dose of Synacthen that is diagnostically most accurate and sensitive is still a matter of debate. We investigated 15 healthy men with mean/median age 27.4/26 (SD ±4.8 years, and mean/median BMI (body mass index 25.38/24.82 (SD ±3.2 kg/m2. All subjects underwent 4 dynamic tests of the HPA axis, specifically 1 μg, 10 μg, and 250 μg Synacthen (ACTH tests and an ITT. Salivary cortisol, cortisone, pregnenolone, and DHEA (dehydroepiandrosterone were analysed using liquid chromatography-tandem mass spectrometry. During the ITT maximum salivary cortisol levels over 12.5 nmol/l were found at 60 minutes. Maximum cortisol levels in all of the Synacthen tests were higher than this; however, demonstrating that sufficient stimulation of the adrenal glands was achieved. Cortisone reacted similarly as cortisol, i.e. we did not find any change in the ratio of cortisol to cortisone. Pregnenolone and DHEA were higher during the ITT, and their peaks preceded the cortisol peak. There was no increase of pregnenolone or DHEA in any of the Synacthen tests. We demonstrate that the 10 μg Synacthen dose is sufficient stimulus for testing the HPA axis and is also a safe and cost-effective alternative. This dose also largely eliminates both false negative and false positive results.

  5. Yield and cost of individual common diagnostic tests in new primary care outpatients in Japan.

    Science.gov (United States)

    Takemura, Yuzuru; Ishida, Haku; Inoue, Yuji; Beck, J Robert

    2002-01-01

    Appropriate diagnostic testing involves considerations of cost-effectiveness. We examined the cost-effectiveness of individual tests in a panel of tests defined by the Japan Society of Clinical Pathology. We studied 540 new, symptomatic primary care outpatients with a set of 30 common diagnostic tests [the Essential Laboratory Tests (2); ELT(2) panel] for clinical evaluation and identification of occult disease. A useful result (UR) of testing was defined as a finding that contributed to a change in a physician's diagnosis or decision-making relating to a "tentative initial diagnosis" obtained from history and physical examination alone. The ELT(2) panel testing yielded 398 URs and uncovered 261 occult diseases among 540 patients. In total, 1592 tests contributed to either UR-generation or discovery of occult disease. The cost per effective test (cost required per test that contributed to either definition of effectiveness) ranged from 108 yen (approximately 0.92 US dollars) for total cholesterol to 6200 yen (approximately 52.50 dollars) for chest x-ray. Contribution rates and the cost per effective test varied among disease categories. We restructured panel components considering the effectiveness of each test. Subsets of the ELT(2) would have improved cost-effectiveness and achieved cost savings in five of eight disease categories. Assembly of tests based on cost-effectiveness can improve clinical efficiency and decrease total cost of panel testing for selected patient groups.

  6. Nonparametric predictive inference for combining diagnostic tests with parametric copula

    Science.gov (United States)

    Muhammad, Noryanti; Coolen, F. P. A.; Coolen-Maturi, T.

    2017-09-01

    Measuring the accuracy of diagnostic tests is crucial in many application areas including medicine and health care. The Receiver Operating Characteristic (ROC) curve is a popular statistical tool for describing the performance of diagnostic tests. The area under the ROC curve (AUC) is often used as a measure of the overall performance of the diagnostic test. In this paper, we interest in developing strategies for combining test results in order to increase the diagnostic accuracy. We introduce nonparametric predictive inference (NPI) for combining two diagnostic test results with considering dependence structure using parametric copula. NPI is a frequentist statistical framework for inference on a future observation based on past data observations. NPI uses lower and upper probabilities to quantify uncertainty and is based on only a few modelling assumptions. While copula is a well-known statistical concept for modelling dependence of random variables. A copula is a joint distribution function whose marginals are all uniformly distributed and it can be used to model the dependence separately from the marginal distributions. In this research, we estimate the copula density using a parametric method which is maximum likelihood estimator (MLE). We investigate the performance of this proposed method via data sets from the literature and discuss results to show how our method performs for different family of copulas. Finally, we briefly outline related challenges and opportunities for future research.

  7. ITER diagnostics: Maintenance and commissioning in the hot cell test bed

    International Nuclear Information System (INIS)

    Walker, C.I.; Barnsley, R.; Costley, A.E.; Gottfried, R.; Haist, B.; Itami, K.; Kondoh, T.; Loesser, G.D.; Palmer, J.; Sugie, T.; Tesini, A.; Vayakis, G.

    2005-01-01

    In-vessel diagnostic equipment in ITER integrated in six equatorial and 12 upper ports, 16 divertor cassettes and five lower ports is designed to be removed in modules and then repaired, tested and commissioned in the same location at the ITER hot cell. The repair requirements and tests on these components are described along with design features that facilitate repair. The testing establishes the repair strategy, qualifies the refurbishment work and finally checks the mechanical and diagnostic function before the return of the modules. At the hot cell, a dummy port is provided for tests of mechanical and vacuum integrity as well as commissioning of the diagnostic equipment. The scope of the hot cell maintenance and commissioning activities is summarised and an overview of the integration of the diagnostic equipment is given

  8. Diagnostic reliability of MMPI-2 computer-based test interpretations.

    Science.gov (United States)

    Pant, Hina; McCabe, Brian J; Deskovitz, Mark A; Weed, Nathan C; Williams, John E

    2014-09-01

    Reflecting the common use of the MMPI-2 to provide diagnostic considerations, computer-based test interpretations (CBTIs) also typically offer diagnostic suggestions. However, these diagnostic suggestions can sometimes be shown to vary widely across different CBTI programs even for identical MMPI-2 profiles. The present study evaluated the diagnostic reliability of 6 commercially available CBTIs using a 20-item Q-sort task developed for this study. Four raters each sorted diagnostic classifications based on these 6 CBTI reports for 20 MMPI-2 profiles. Two questions were addressed. First, do users of CBTIs understand the diagnostic information contained within the reports similarly? Overall, diagnostic sorts of the CBTIs showed moderate inter-interpreter diagnostic reliability (mean r = .56), with sorts for the 1/2/3 profile showing the highest inter-interpreter diagnostic reliability (mean r = .67). Second, do different CBTIs programs vary with respect to diagnostic suggestions? It was found that diagnostic sorts of the CBTIs had a mean inter-CBTI diagnostic reliability of r = .56, indicating moderate but not strong agreement across CBTIs in terms of diagnostic suggestions. The strongest inter-CBTI diagnostic agreement was found for sorts of the 1/2/3 profile CBTIs (mean r = .71). Limitations and future directions are discussed. PsycINFO Database Record (c) 2014 APA, all rights reserved.

  9. A diagnostic test for apraxia in stroke patients: internal consistency and diagnostic value.

    NARCIS (Netherlands)

    Heugten, C.M. van; Dekker, J.; Deelman, B.G.; Stehmann-Saris, F.C.; Kinebanian, A.

    1999-01-01

    The internal consistency and the diagnostic value of a test for apraxia in patients having had a stroke are presented. Results indicate that the items of the test form a strong and consistent scale: Cronbach's alpha as well as the results of a Mokken scale analysis present good reliability and good

  10. Analysis of the Astronomy Diagnostic Test

    Science.gov (United States)

    Brogt, Erik; Sabers, Darrell; Prather, Edward E.; Deming, Grace L.; Hufnagel, Beth; Slater, Timothy F.

    2007-01-01

    Seventy undergraduate class sections were examined from the database of Astronomy Diagnostic Test (ADT) results of Deming and Hufnagel to determine if course format correlated with ADT normalized gain scores. Normalized gains were calculated for four different classroom scenarios: lecture, lecture with discussion, lecture with lab, and lecture…

  11. Diagnostic development and support of MHD test facilities

    Energy Technology Data Exchange (ETDEWEB)

    1990-01-01

    The Diagnostic Instrumentation and Analysis Laboratory (DIAL) at Mississippi State University (MSU) is developing diagnostic instruments for MHD power train data acquisition and for support of MHD component development test facilities. Microprocessor-controlled optical instruments, initially developed for Heat Recovery/Seed Recovery support, are being refined, and new systems to measure temperatures and gas-seed-slag stream characteristics are being developed. To further data acquisition and analysis capabilities, the diagnostic systems are being interfaced with DIAL's computers. Technical support for the diagnostic needs of the national MHD research effort is being provided. DIAL personnel will also cooperate with government agencies and private industries to improve the transformation of research and development results into processes, products and services applicable to their needs. 25 figs., 6 tabs.

  12. Diagnostic development and support of MHD test facilities

    International Nuclear Information System (INIS)

    Shepard, W.S.; Cook, R.L.

    1990-01-01

    The Diagnostic Instrumentation and Analysis Laboratory (DIAL) at Mississippi State University (MSU) is developing diagnostic instruments for MHD power train data acquisition and for support of MHD component development test facilities. Microprocessor-controlled optical instruments, initially developed for Heat Recovery/ Seed Recovery support, are being refined, and new systems to measure temperatures and gas-seed-slag stream characteristics are being developed. To further data acquisition and analysis capabilities, the diagnostic systems are being interfaced with DIAL's computers. Technical support for the diagnostic needs of the national MHD research effort is being provided. DIAL personnel will also cooperate with government agencies and private industries to improve the transformation of research and development results into processes, products and services applicable to their needs

  13. 9 CFR 147.8 - Procedures for preparing egg yolk samples for diagnostic tests.

    Science.gov (United States)

    2010-01-01

    ... samples for diagnostic tests. 147.8 Section 147.8 Animals and Animal Products ANIMAL AND PLANT HEALTH... IMPROVEMENT PLAN Blood Testing Procedures § 147.8 Procedures for preparing egg yolk samples for diagnostic... for diagnostic testing. (b) The authorized laboratory must identify each egg as to the breeding flock...

  14. Rapid diagnostic tests for typhoid and paratyphoid (enteric) fever.

    Science.gov (United States)

    Wijedoru, Lalith; Mallett, Sue; Parry, Christopher M

    2017-05-26

    Differentiating both typhoid (Salmonella Typhi) and paratyphoid (Salmonella Paratyphi A) infection from other causes of fever in endemic areas is a diagnostic challenge. Although commercial point-of-care rapid diagnostic tests (RDTs) for enteric fever are available as alternatives to the current reference standard test of blood or bone marrow culture, or to the widely used Widal Test, their diagnostic accuracy is unclear. If accurate, they could potentially replace blood culture as the World Health Organization (WHO)-recommended main diagnostic test for enteric fever. To assess the diagnostic accuracy of commercially available rapid diagnostic tests (RDTs) and prototypes for detecting Salmonella Typhi or Paratyphi A infection in symptomatic persons living in endemic areas. We searched the Cochrane Infectious Diseases Group Specialized Register, MEDLINE, Embase, Science Citation Index, IndMED, African Index Medicus, LILACS, ClinicalTrials.gov, and the World Health Organization (WHO) International Clinical Trials Registry Platform (ICTRP) up to 4 March 2016. We manually searched WHO reports, and papers from international conferences on Salmonella infections. We also contacted test manufacturers to identify studies. We included diagnostic accuracy studies of enteric fever RDTs in patients with fever or with symptoms suggestive of enteric fever living in endemic areas. We classified the reference standard used as either Grade 1 (result from a blood culture and a bone marrow culture) or Grade 2 (result from blood culture and blood polymerase chain reaction, or from blood culture alone). Two review authors independently extracted the test result data. We used a modified QUADAS-2 extraction form to assess methodological quality. We performed a meta-analysis when there were sufficient studies for the test and heterogeneity was reasonable. Thirty-seven studies met the inclusion criteria and included a total of 5080 participants (range 50 to 1732). Enteric fever prevalence

  15. Antiphospholipid Syndrome Laboratory Testing and Diagnostic Strategies

    Science.gov (United States)

    Ortel, Thomas L.

    2016-01-01

    The Antiphospholipid Syndrome (APS) is diagnosed in patients with recurrent thromboembolic events and/or pregnancy loss in the presence of persistent laboratory evidence for antiphospholipid antibodies. Diagnostic tests for the detection of antiphospholipid antibodies include laboratory assays that detect anticardiolipin antibodies, lupus anticoagulants, and anti-β2-glycoprotein I antibodies. These assays have their origins beginning more than sixty years ago, with the identification of the biologic false positive test for syphilis, the observation of ‘circulating anticoagulants’ in certain patients with systemic lupus erythematosus, the identification of cardiolipin as a key component in the serologic test for syphilis, and the recognition and characterization of a ‘cofactor’ for antibody binding to phospholipids. Although these assays have been used clinically for many years, there are still problems with the accurate diagnosis of patients with this syndrome. For example, lupus anticoagulant testing can be difficult to interpret in patients receiving anticoagulant therapy, but most patients with a thromboembolic event will already be anticoagulated before the decision to perform the tests has been made. In addition to understanding limitations of the assays, clinicians also need to be aware of which patients should be tested and not obtain testing on patients unlikely to have APS. New tests and diagnostic strategies are in various stages of development and should help improve our ability to accurately diagnose this important clinical disorder. PMID:22473619

  16. 30 CFR 250.522 - When do I have to repeat casing diagnostic testing?

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 2 2010-07-01 2010-07-01 false When do I have to repeat casing diagnostic... Operations Casing Pressure Management § 250.522 When do I have to repeat casing diagnostic testing? Casing diagnostic testing must be repeated according to the following table: When * * * you must repeat diagnostic...

  17. More Than Just Accuracy: A Novel Method to Incorporate Multiple Test Attributes in Evaluating Diagnostic Tests Including Point of Care Tests.

    Science.gov (United States)

    Thompson, Matthew; Weigl, Bernhard; Fitzpatrick, Annette; Ide, Nicole

    2016-01-01

    Current frameworks for evaluating diagnostic tests are constrained by a focus on diagnostic accuracy, and assume that all aspects of the testing process and test attributes are discrete and equally important. Determining the balance between the benefits and harms associated with new or existing tests has been overlooked. Yet, this is critically important information for stakeholders involved in developing, testing, and implementing tests. This is particularly important for point of care tests (POCTs) where tradeoffs exist between numerous aspects of the testing process and test attributes. We developed a new model that multiple stakeholders (e.g., clinicians, patients, researchers, test developers, industry, regulators, and health care funders) can use to visualize the multiple attributes of tests, the interactions that occur between these attributes, and their impacts on health outcomes. We use multiple examples to illustrate interactions between test attributes (test availability, test experience, and test results) and outcomes, including several POCTs. The model could be used to prioritize research and development efforts, and inform regulatory submissions for new diagnostics. It could potentially provide a way to incorporate the relative weights that various subgroups or clinical settings might place on different test attributes. Our model provides a novel way that multiple stakeholders can use to visualize test attributes, their interactions, and impacts on individual and population outcomes. We anticipate that this will facilitate more informed decision making around diagnostic tests.

  18. Molecular Diagnostic Tests for Microsporidia

    Directory of Open Access Journals (Sweden)

    Kaya Ghosh

    2009-01-01

    Full Text Available The Microsporidia are a ubiquitous group of eukaryotic obligate intracellular parasites which were recognized over 100 years ago with the description of Nosema bombycis, a parasite of silkworms. It is now appreciated that these organisms are related to the Fungi. Microsporidia infect all major animal groups most often as gastrointestinal pathogens; however they have been reported from every tissue and organ, and their spores are common in environmental sources such as ditch water. Several different genera of these organisms infect humans, but the majority of infections are due to either Enterocytozoon bieneusi or Encephalitozoon species. These pathogens can be difficult to diagnose, but significant progress has been made in the last decade in the development of molecular diagnostic reagents for these organisms. This report reviews the molecular diagnostic tests that have been described for the identification of the microsporidia that infect humans.

  19. Network meta-analysis of diagnostic test accuracy studies identifies and ranks the optimal diagnostic tests and thresholds for health care policy and decision-making.

    Science.gov (United States)

    Owen, Rhiannon K; Cooper, Nicola J; Quinn, Terence J; Lees, Rosalind; Sutton, Alex J

    2018-07-01

    Network meta-analyses (NMA) have extensively been used to compare the effectiveness of multiple interventions for health care policy and decision-making. However, methods for evaluating the performance of multiple diagnostic tests are less established. In a decision-making context, we are often interested in comparing and ranking the performance of multiple diagnostic tests, at varying levels of test thresholds, in one simultaneous analysis. Motivated by an example of cognitive impairment diagnosis following stroke, we synthesized data from 13 studies assessing the efficiency of two diagnostic tests: Mini-Mental State Examination (MMSE) and Montreal Cognitive Assessment (MoCA), at two test thresholds: MMSE accounting for the correlations between multiple test accuracy measures from the same study. We developed and successfully fitted a model comparing multiple tests/threshold combinations while imposing threshold constraints. Using this model, we found that MoCA at threshold decision making. Copyright © 2018 The Authors. Published by Elsevier Inc. All rights reserved.

  20. Efficient strategies to find diagnostic test accuracy studies in kidney journals.

    Science.gov (United States)

    Rogerson, Thomas E; Ladhani, Maleeka; Mitchell, Ruth; Craig, Jonathan C; Webster, Angela C

    2015-08-01

    Nephrologists looking for quick answers to diagnostic clinical questions in MEDLINE can use a range of published search strategies or Clinical Query limits to improve the precision of their searches. We aimed to evaluate existing search strategies for finding diagnostic test accuracy studies in nephrology journals. We assessed the accuracy of 14 search strategies for retrieving diagnostic test accuracy studies from three nephrology journals indexed in MEDLINE. Two investigators hand searched the same journals to create a reference set of diagnostic test accuracy studies to compare search strategy results against. We identified 103 diagnostic test accuracy studies, accounting for 2.1% of all studies published. The most specific search strategy was the Narrow Clinical Queries limit (sensitivity: 0.20, 95% CI 0.13-0.29; specificity: 0.99, 95% CI 0.99-0.99). Using the Narrow Clinical Queries limit, a searcher would need to screen three (95% CI 2-6) articles to find one diagnostic study. The most sensitive search strategy was van der Weijden 1999 Extended (sensitivity: 0.95; 95% CI 0.89-0.98; specificity 0.55, 95% CI 0.53-0.56) but required a searcher to screen 24 (95% CI 23-26) articles to find one diagnostic study. Bachmann 2002 was the best balanced search strategy, which was sensitive (0.88, 95% CI 0.81-0.94), but also specific (0.74, 95% CI 0.73-0.75), with a number needed to screen of 15 (95% CI 14-17). Diagnostic studies are infrequently published in nephrology journals. The addition of a strategy for diagnostic studies to a subject search strategy in MEDLINE may reduce the records needed to screen while preserving adequate search sensitivity for routine clinical use. © 2015 Asian Pacific Society of Nephrology.

  1. Subjective Well-Being, Test Anxiety, Academic Achievement: Testing for Reciprocal Effects.

    Science.gov (United States)

    Steinmayr, Ricarda; Crede, Julia; McElvany, Nele; Wirthwein, Linda

    2015-01-01

    In the context of adolescents' subjective well-being (SWB), research has recently focused on a number of different school variables. The direction of the relationships between adolescents' SWB, academic achievement, and test anxiety is, however, still open although reciprocal causation has been hypothesized. The present study set out to investigate to what extent SWB, academic achievement, and test anxiety influence each other over time. A sample of N = 290 11th grade students (n = 138 female; age: M = 16.54 years, SD = 0.57) completed measures of SWB and test anxiety in the time span of 1 year. Grade point average (GPA) indicated students' academic achievement. We analyzed the reciprocal relations using cross-lagged structural equation modeling. The model fit was satisfactory for all computed models. Results indicated that the worry component of test anxiety negatively and GPA positively predicted changes in the cognitive component of SWB (life satisfaction). Worry also negatively predicted changes in the affective component of SWB. Moreover, worry negatively predicted changes in students' GPA. Directions for future research and the differential predictive influences of academic achievement and test anxiety on adolescents' SWB are discussed with regard to potential underlying processes.

  2. Subjective Well-Being, Test Anxiety, Academic Achievement: Testing for Reciprocal Effects

    Directory of Open Access Journals (Sweden)

    Ricarda eSteinmayr

    2016-01-01

    Full Text Available In the context of adolescents’ subjective well-being (SWB, research has recently focused on a number of different school variables. The direction of the relationships between adolescents’ SWB, academic achievement, and test anxiety is however still open although reciprocal causation has been hypothesized. The present study set out to investigate to what extent SWB, academic achievement, and test anxiety influence each other over time. A sample of N = 290 11th grade students (n = 138 female; age: M = 16.54 years, SD = 0.57 completed measures of SWB and test anxiety in the time span of one year. Grade Point Average (GPA indicated students’ academic achievement. We analyzed the reciprocal relations using cross-lagged structural equation modeling. The model fit was satisfactory for all computed models. Results indicated that the worry component of test anxiety negatively and GPA positively predicted changes in the cognitive component of SWB (life satisfaction. Worry also negatively predicted changes in the affective component of SWB. Moreover, worry negatively predicted changes in students’ GPA. Directions for future research and the differential predictive influences of academic achievement and test anxiety on adolescents’ SWB are discussed with regard to potential underlying processes.

  3. Characterization of the Goubau line for testing beam diagnostic instruments

    Science.gov (United States)

    Kim, S. Y.; Stulle, F.; Sung, C. K.; Yoo, K. H.; Seok, J.; Moon, K. J.; Choi, C. U.; Chung, Y.; Kim, G.; Woo, H. J.; Kwon, J.; Lee, I. G.; Choi, E. M.; Chung, M.

    2017-12-01

    One of the main characteristics of the Goubau line is that it supports a low-loss, non-radiated surface wave guided by a dielectric-coated metal wire. The dominant mode of the surface wave along the Goubau line is a TM01 mode, which resembles the pattern of the electromagnetic fields induced in the metallic beam pipe when the charged particle beam passes through it. Therefore, the Goubau line can be used for the preliminary bench test and performance optimization of the beam diagnostic instruments without requiring charged particle beams from the accelerators. In this paper, we discuss the basic properties of the Goubau line for testing beam diagnostic instruments and present the initial test results for button-type beam position monitors (BPMs). The experimental results are consistent with the theoretical estimations, which indicates that Goubau line allows effective testing of beam diagnostic equipment.

  4. Mixed Portmanteau Test for Diagnostic Checking of Time Series Models

    Directory of Open Access Journals (Sweden)

    Sohail Chand

    2014-01-01

    Full Text Available Model criticism is an important stage of model building and thus goodness of fit tests provides a set of tools for diagnostic checking of the fitted model. Several tests are suggested in literature for diagnostic checking. These tests use autocorrelation or partial autocorrelation in the residuals to criticize the adequacy of fitted model. The main idea underlying these portmanteau tests is to identify if there is any dependence structure which is yet unexplained by the fitted model. In this paper, we suggest mixed portmanteau tests based on autocorrelation and partial autocorrelation functions of the residuals. We derived the asymptotic distribution of the mixture test and studied its size and power using Monte Carlo simulations.

  5. Development of diagnostic test instruments to reveal level student conception in kinematic and dynamics

    Science.gov (United States)

    Handhika, J.; Cari, C.; Suparmi, A.; Sunarno, W.; Purwandari, P.

    2018-03-01

    The purpose of this research was to develop a diagnostic test instrument to reveal students' conceptions in kinematics and dynamics. The diagnostic test was developed based on the content indicator the concept of (1) displacement and distance, (2) instantaneous and average velocity, (3) zero and constant acceleration, (4) gravitational acceleration (5) Newton's first Law, (6) and Newton's third Law. The diagnostic test development model includes: Diagnostic test requirement analysis, formulating test-making objectives, developing tests, checking the validity of the content and the performance of reliability, and application of tests. The Content Validation Index (CVI) results in the category are highly relevant, with a value of 0.85. Three questions get negative Content Validation Ratio CVR) (-0.6), after revised distractors and clarify visual presentation; the CVR become 1 (highly relevant). This test was applied, obtained 16 valid test items, with Cronbach Alpha value of 0.80. It can conclude that diagnostic test can be used to reveal the level of students conception in kinematics and dynamics.

  6. Fuel-motion diagnostics and cineradiography

    International Nuclear Information System (INIS)

    DeVolpi, A.

    1982-09-01

    Nuclear and non-nuclear applications of cineradiography are reviewed, with emphasis on diagnostic instrumentation for in-pile transient-reactor safety testing of nuclear fuel motion. The primary instrument for this purpose has been the fast-neutron hodoscope, which has achieved quantitative monitoring of time, location, mass, and velocity of fuel movement under the difficult conditions associated with transient-reactor experiments. Alternative diagnostic devices that have been developed have not matched the capabilities of the hodoscope. Other applications for the fuel-motion diagnostic apparatus are also evolving, including time-integrated radiography and direct time- and space-resolved fuel-pin power monitoring. Although only two reactors are now actively equipped with high-resolution fuel-motion diagnostic systems, studies and tests have been carried out in and for many other reactors

  7. Rapid diagnostic tests for typhoid and paratyphoid (enteric) fever

    Science.gov (United States)

    Wijedoru, Lalith; Mallett, Sue; Parry, Christopher M

    2017-01-01

    Background Differentiating both typhoid (Salmonella Typhi) and paratyphoid (Salmonella Paratyphi A) infection from other causes of fever in endemic areas is a diagnostic challenge. Although commercial point-of-care rapid diagnostic tests (RDTs) for enteric fever are available as alternatives to the current reference standard test of blood or bone marrow culture, or to the widely used Widal Test, their diagnostic accuracy is unclear. If accurate, they could potentially replace blood culture as the World Health Organization (WHO)-recommended main diagnostic test for enteric fever. Objectives To assess the diagnostic accuracy of commercially available rapid diagnostic tests (RDTs) and prototypes for detecting Salmonella Typhi or Paratyphi A infection in symptomatic persons living in endemic areas. Search methods We searched the Cochrane Infectious Diseases Group Specialized Register, MEDLINE, Embase, Science Citation Index, IndMED, African Index Medicus, LILACS, ClinicalTrials.gov, and the World Health Organization (WHO) International Clinical Trials Registry Platform (ICTRP) up to 4 March 2016. We manually searched WHO reports, and papers from international conferences on Salmonella infections. We also contacted test manufacturers to identify studies. Selection criteria We included diagnostic accuracy studies of enteric fever RDTs in patients with fever or with symptoms suggestive of enteric fever living in endemic areas. We classified the reference standard used as either Grade 1 (result from a blood culture and a bone marrow culture) or Grade 2 (result from blood culture and blood polymerase chain reaction, or from blood culture alone). Data collection and analysis Two review authors independently extracted the test result data. We used a modified QUADAS-2 extraction form to assess methodological quality. We performed a meta-analysis when there were sufficient studies for the test and heterogeneity was reasonable. Main results Thirty-seven studies met the inclusion

  8. Diagnostic value of serologic tests in celiac screening

    Directory of Open Access Journals (Sweden)

    Hosein Saneian

    2012-01-01

    Conclusions: According to our study results, there is no correlation between gastrointestinal symptoms such as vomiting diarrhea, anorexia, bulimia, and failure to thrive (FFT with celiac. TTG was the best screening test method to diagnose celiac disease and other tests such as AGA and EMA do not have high diagnostic value.

  9. Compare diagnostic tests using transformation-invariant smoothed ROC curves⋆

    Science.gov (United States)

    Tang, Liansheng; Du, Pang; Wu, Chengqing

    2012-01-01

    Receiver operating characteristic (ROC) curve, plotting true positive rates against false positive rates as threshold varies, is an important tool for evaluating biomarkers in diagnostic medicine studies. By definition, ROC curve is monotone increasing from 0 to 1 and is invariant to any monotone transformation of test results. And it is often a curve with certain level of smoothness when test results from the diseased and non-diseased subjects follow continuous distributions. Most existing ROC curve estimation methods do not guarantee all of these properties. One of the exceptions is Du and Tang (2009) which applies certain monotone spline regression procedure to empirical ROC estimates. However, their method does not consider the inherent correlations between empirical ROC estimates. This makes the derivation of the asymptotic properties very difficult. In this paper we propose a penalized weighted least square estimation method, which incorporates the covariance between empirical ROC estimates as a weight matrix. The resulting estimator satisfies all the aforementioned properties, and we show that it is also consistent. Then a resampling approach is used to extend our method for comparisons of two or more diagnostic tests. Our simulations show a significantly improved performance over the existing method, especially for steep ROC curves. We then apply the proposed method to a cancer diagnostic study that compares several newly developed diagnostic biomarkers to a traditional one. PMID:22639484

  10. The diagnostic odds ratio: a single indicator of test performance

    NARCIS (Netherlands)

    Glas, Afina S.; Lijmer, Jeroen G.; Prins, Martin H.; Bonsel, Gouke J.; Bossuyt, Patrick M. M.

    2003-01-01

    Diagnostic testing can be used to discriminate subjects with a target disorder from subjects without it. Several indicators of diagnostic performance have been proposed, such as sensitivity and specificity. Using paired indicators can be a disadvantage in comparing the performance of competing

  11. Diagnostic accuracy of temporomandibular disorder pain tests: a multicenter study

    NARCIS (Netherlands)

    Visscher, C.M.; Naeije, M.; de Laat, A.; Michelotti, A.; Nilner, M.; Craane, B.; Ekberg, E.; Farella, M.; Lobbezoo, F.

    2009-01-01

    AIMS: To estimate the diagnostic accuracy of the Research Diagnostic Criteria for Temporomandibular Disorders (RDC/TMD) clinical examination and of the dynamic/static tests for the recognition of TMD pain. Since the diagnosis of TMD pain is especially complicated in persistent orofacial pain

  12. Optimal Sequential Diagnostic Strategy Generation Considering Test Placement Cost for Multimode Systems

    Directory of Open Access Journals (Sweden)

    Shigang Zhang

    2015-10-01

    Full Text Available Sequential fault diagnosis is an approach that realizes fault isolation by executing the optimal test step by step. The strategy used, i.e., the sequential diagnostic strategy, has great influence on diagnostic accuracy and cost. Optimal sequential diagnostic strategy generation is an important step in the process of diagnosis system construction, which has been studied extensively in the literature. However, previous algorithms either are designed for single mode systems or do not consider test placement cost. They are not suitable to solve the sequential diagnostic strategy generation problem considering test placement cost for multimode systems. Therefore, this problem is studied in this paper. A formulation is presented. Two algorithms are proposed, one of which is realized by system transformation and the other is newly designed. Extensive simulations are carried out to test the effectiveness of the algorithms. A real-world system is also presented. All the results show that both of them have the ability to solve the diagnostic strategy generation problem, and they have different characteristics.

  13. Optimal Sequential Diagnostic Strategy Generation Considering Test Placement Cost for Multimode Systems

    Science.gov (United States)

    Zhang, Shigang; Song, Lijun; Zhang, Wei; Hu, Zheng; Yang, Yongmin

    2015-01-01

    Sequential fault diagnosis is an approach that realizes fault isolation by executing the optimal test step by step. The strategy used, i.e., the sequential diagnostic strategy, has great influence on diagnostic accuracy and cost. Optimal sequential diagnostic strategy generation is an important step in the process of diagnosis system construction, which has been studied extensively in the literature. However, previous algorithms either are designed for single mode systems or do not consider test placement cost. They are not suitable to solve the sequential diagnostic strategy generation problem considering test placement cost for multimode systems. Therefore, this problem is studied in this paper. A formulation is presented. Two algorithms are proposed, one of which is realized by system transformation and the other is newly designed. Extensive simulations are carried out to test the effectiveness of the algorithms. A real-world system is also presented. All the results show that both of them have the ability to solve the diagnostic strategy generation problem, and they have different characteristics. PMID:26457709

  14. Background review for diagnostic test development for Zika virus infection.

    Science.gov (United States)

    Charrel, Rémi N; Leparc-Goffart, Isabelle; Pas, Suzan; de Lamballerie, Xavier; Koopmans, Marion; Reusken, Chantal

    2016-08-01

    To review the state of knowledge about diagnostic testing for Zika virus infection and identify areas of research needed to address the current gaps in knowledge. We made a non-systematic review of the published literature about Zika virus and supplemented this with information from commercial diagnostic test kits and personal communications with researchers in European preparedness networks. The review covered current knowledge about the geographical spread, pathogen characteristics, life cycle and infection kinetics of the virus. The available molecular and serological tests and biosafety issues are described and discussed in the context of the current outbreak strain. We identified the following areas of research to address current knowledge gaps: (i) an urgent assessment of the laboratory capacity and capability of countries to detect Zika virus; (ii) rapid and extensive field validation of the available molecular and serological tests in areas with and without Zika virus transmission, with a focus on pregnant women; (iii) monitoring the genomic diversity of circulating Zika virus strains; (iv) prospective studies into the virus infection kinetics, focusing on diagnostic sampling (specimen types, combinations and timings); and (v) developing external quality assessments for molecular and serological testing, including differential diagnosis for similar viruses and symptom clusters. The availability of reagents for diagnostic development (virus strains and antigens, quantified viral ribonucleic acid) needs to be facilitated. An international laboratory response is needed, including preparation of protocols for prospective studies to address the most pressing information needs.

  15. Can Emergency Medicine Residents Predict Cost of Diagnostic Testing?

    Directory of Open Access Journals (Sweden)

    Tainter, Christopher R

    2017-01-01

    Full Text Available Diagnostic testing represents a significant portion of healthcare spending, and cost should be considered when ordering such tests. Needless and excessive spending may occur without an appreciation of the impact on the larger healthcare system. Knowledge regarding the cost of diagnostic testing among emergency medicine (EM residents has not previously been studied. A survey was administered to 20 EM residents from a single ACGME-accredited three-year EM residency program, asking for an estimation of patient charges for 20 commonly ordered laboratory tests and seven radiological exams. We compared responses between residency classes to evaluate whether there was a difference based on level of training. The survey completion rate was 100% (20/20 residents. We noted significant discrepancies between the median resident estimates and actual charge to patient for both laboratory and radiological exams. Nearly all responses were an underestimate of the actual cost. The group median underestimation for laboratory testing was $114, for radiographs $57, and for computed tomography exams was $1,058. There was improvement in accuracy with increasing level of training. This pilot study demonstrates that EM residents have a poor understanding of the charges burdening patients and health insurance providers. In order to make balanced decisions with regard to diagnostic testing, providers must appreciate these factors. Education regarding the cost of providing emergency care is a potential area for improvement of EM residency curricula, and warrants further attention and investigation.

  16. Laboratory development and testing of spacecraft diagnostics

    Science.gov (United States)

    Amatucci, William; Tejero, Erik; Blackwell, Dave; Walker, Dave; Gatling, George; Enloe, Lon; Gillman, Eric

    2017-10-01

    The Naval Research Laboratory's Space Chamber experiment is a large-scale laboratory device dedicated to the creation of large-volume plasmas with parameters scaled to realistic space plasmas. Such devices make valuable contributions to the investigation of space plasma phenomena under controlled, reproducible conditions, allowing for the validation of theoretical models being applied to space data. However, in addition to investigations such as plasma wave and instability studies, such devices can also make valuable contributions to the development and testing of space plasma diagnostics. One example is the plasma impedance probe developed at NRL. Originally developed as a laboratory diagnostic, the sensor has now been flown on a sounding rocket, is included on a CubeSat experiment, and will be included on the DoD Space Test Program's STP-H6 experiment on the International Space Station. In this talk, we will describe how the laboratory simulation of space plasmas made this development path possible. Work sponsored by the US Naval Research Laboratory Base Program.

  17. 30 CFR 250.523 - How long do I keep records of casing pressure and diagnostic tests?

    Science.gov (United States)

    2010-07-01

    ... and diagnostic tests? 250.523 Section 250.523 Mineral Resources MINERALS MANAGEMENT SERVICE... casing pressure and diagnostic tests? Records of casing pressure and diagnostic tests must be kept at the field office nearest the well for a minimum of 2 years. The last casing diagnostic test for each casing...

  18. A low cost, safe, disposable, rapid and self-sustainable paper-based platform for diagnostic testing: lab-on-paper

    International Nuclear Information System (INIS)

    Costa, M N; Veigas, B; Jacob, J M; Santos, D S; Martins, R; Fortunato, E; Gomes, J; Inácio, J; Baptista, P V

    2014-01-01

    There is a strong interest in the use of biopolymers in the electronic and biomedical industries, mainly towards low-cost applications. The possibility of developing entirely new kinds of products based on cellulose is of current interest, in order to enhance and to add new functionalities to conventional paper-based products. We present our results towards the development of paper-based microfluidics for molecular diagnostic testing. Paper properties were evaluated and compared to nitrocellulose, the most commonly used material in lateral flow and other rapid tests. Focusing on the use of paper as a substrate for microfluidic applications, through an eco-friendly wax-printing technology, we present three main and distinct colorimetric approaches: (i) enzymatic reactions (glucose detection); (ii) immunoassays (antibodies anti-Leishmania detection); (iii) nucleic acid sequence identification (Mycobacterium tuberculosis complex detection). Colorimetric glucose quantification was achieved through enzymatic reactions performed within specific zones of the paper-based device. The colouration achieved increased with growing glucose concentration and was highly homogeneous, covering all the surface of the paper reaction zones in a 3D sensor format. These devices showed a major advantage when compared to the 2D lateral flow glucose sensors, where some carryover of the coloured products usually occurs. The detection of anti-Leishmania antibodies in canine sera was conceptually achieved using a paper-based 96-well enzyme-linked immunosorbent assay format. However, optimization is still needed for this test, regarding the efficiency of the immobilization of antigens on the cellulose fibres. The detection of Mycobacterium tuberculosis nucleic acids integrated with a non-cross-linking gold nanoprobe detection scheme was also achieved in a wax-printed 384-well paper-based microplate, by the hybridization with a species-specific probe. The obtained results with the above

  19. A low cost, safe, disposable, rapid and self-sustainable paper-based platform for diagnostic testing: lab-on-paper

    Science.gov (United States)

    Costa, M. N.; Veigas, B.; Jacob, J. M.; Santos, D. S.; Gomes, J.; Baptista, P. V.; Martins, R.; Inácio, J.; Fortunato, E.

    2014-03-01

    There is a strong interest in the use of biopolymers in the electronic and biomedical industries, mainly towards low-cost applications. The possibility of developing entirely new kinds of products based on cellulose is of current interest, in order to enhance and to add new functionalities to conventional paper-based products. We present our results towards the development of paper-based microfluidics for molecular diagnostic testing. Paper properties were evaluated and compared to nitrocellulose, the most commonly used material in lateral flow and other rapid tests. Focusing on the use of paper as a substrate for microfluidic applications, through an eco-friendly wax-printing technology, we present three main and distinct colorimetric approaches: (i) enzymatic reactions (glucose detection); (ii) immunoassays (antibodies anti-Leishmania detection); (iii) nucleic acid sequence identification (Mycobacterium tuberculosis complex detection). Colorimetric glucose quantification was achieved through enzymatic reactions performed within specific zones of the paper-based device. The colouration achieved increased with growing glucose concentration and was highly homogeneous, covering all the surface of the paper reaction zones in a 3D sensor format. These devices showed a major advantage when compared to the 2D lateral flow glucose sensors, where some carryover of the coloured products usually occurs. The detection of anti-Leishmania antibodies in canine sera was conceptually achieved using a paper-based 96-well enzyme-linked immunosorbent assay format. However, optimization is still needed for this test, regarding the efficiency of the immobilization of antigens on the cellulose fibres. The detection of Mycobacterium tuberculosis nucleic acids integrated with a non-cross-linking gold nanoprobe detection scheme was also achieved in a wax-printed 384-well paper-based microplate, by the hybridization with a species-specific probe. The obtained results with the above

  20. Aquifer test interpretation using derivative analysis and diagnostic plots

    Science.gov (United States)

    Hernández-Espriú, Antonio; Real-Rangel, Roberto; Cortés-Salazar, Iván; Castro-Herrera, Israel; Luna-Izazaga, Gabriela; Sánchez-León, Emilio

    2017-04-01

    Pumping tests remain a method of choice to deduce fundamental aquifer properties and to assess well condition. In the oil and gas (O&G) industry, well testing has been the core technique in examining reservoir behavior over the last 50 years. The pressure derivative by Bourdet, it is perhaps, the most significant single development in the history of well test analysis. Recently, the so-called diagnostics plots (e.g. drawdown and drawdown derivative in a log-log plot) have been successfully tested in aquifers. However, this procedure is still underutilized by groundwater professionals. This research illustrates the applicability range, advantages and drawbacks (e.g. smoothing procedures) of diagnostic plots using field examples from a wide spectrum of tests (short/long tests, constant/variable flow rates, drawdown/buildup stages, pumping well/observation well) in dissimilar geological conditions. We analyze new and pre-existent aquifer tests in Mexico, USA, Canada, Germany, France and Saudi Arabia. In constant flow rate tests, our results show that derivative analysis is an easy, robust and powerful tool to assess near-borehole damage effects, formation heterogeneity, boundaries, flow regimes, infinite-acting radial stages, i.e., valid Theisian framework, and fracture-driven flow. In step tests, the effectiveness relies on high-frequency drawdown measurements. Moreover, we adapt O&G analytical solutions to cater for the conditions in groundwater systems. In this context, further parameters can be computed analytically from the plots, such as skin factor, head losses, wellbore storage, distance to the boundary, channel-aquifer and/or fracture zone width, among others. Therefore, diagnostic plots should be considered a mandatory tool for pumping tests analysis among hydrogeologists. This project has been supported by DGAPA (UNAM) under the research project PAPIIT IN-112815.

  1. Heavy ion beams from an Alphatross source for use in calibration and testing of diagnostics

    Science.gov (United States)

    Ward, R. J.; Brown, G. M.; Ho, D.; Stockler, B. F. O. F.; Freeman, C. G.; Padalino, S. J.; Regan, S. P.

    2016-10-01

    Ion beams from the 1.7 MV Pelletron Accelerator at SUNY Geneseo have been used to test and calibrate many inertial confinement fusion (ICF) diagnostics and high energy density physics (HEDP) diagnostics used at the Laboratory for Laser Energetics (LLE). The ion source on this accelerator, a radio-frequency (RF) alkali-metal charge exchange source called an Alphatross, is designed to produce beams of hydrogen and helium isotopes. There is interest in accelerating beams of carbon, oxygen, argon, and other heavy ions for use in testing several diagnostics, including the Time Resolved Tandem Faraday Cup (TRTF). The feasibility of generating these heavy ion beams using the Alphatross source will be reported. Small amounts of various gases are mixed into the helium plasma in the ion source bottle. A velocity selector is used to allow the desired ions to pass into the accelerator. As the heavy ions pass through the stripper canal of the accelerator, they emerge in a variety of charge states. The energy of the ion beam at the high-energy end of the accelerator will vary as a function of the charge state, however the maximum energy deliverable to target is limited by the maximum achievable magnetic field produced by the accelerator's steering magnet. This material is based upon work supported by the Department of Energy National Nuclear Security Administration under Award Number DE-NA0001944.

  2. Assessing Old and New Diagnostic Tests for Gastroesophageal Reflux Disease.

    Science.gov (United States)

    Vaezi, Michael F; Sifrim, Daniel

    2018-01-01

    A detailed critique of objective measurements of gastroesophageal reflux disease (GERD) would improve management of patients suspecting of having reflux, leading to rational selection of treatment and better outcomes. Many diagnostic tests for GERD have been developed over the past decades. We analyze their development, positive- and negative-predictive values, and ability to predict response to treatment. These features are important for development of medical, surgical, and endoscopic therapies for GERD. We discuss the value of available diagnostic tests and review their role in management of patients with persistent reflux symptoms despite adequate medical or surgical treatment. This is becoming a significant health economic problem, due to the widespread use of proton pump inhibitors. GERD is believed to cause nonesophageal symptoms, such as those provoked by ear, nose, throat, or respiratory disorders. We analyze the value of GERD diagnostic tests in evaluation of these troublesome, nonesophageal symptoms. Copyright © 2018 AGA Institute. Published by Elsevier Inc. All rights reserved.

  3. Comparison of the Reading Subtests of the Wechsler Individual Achievement Test-Third Edition and the Peabody Individual Achievement Test-Revised/Normative Update

    Science.gov (United States)

    Ott, Lauren M.

    2010-01-01

    This study compared the reading subtests of the Wechsler Individual Achievement Test-Third Edition and the Peabody Individual Achievement Test-Revised/Normative Update. Scores were compared on these two tests in a group of 28 students ages 7 through 12 who were referred or reevaluated for suspected learning problems. The data were collected…

  4. Dry Eye Disease: Concordance Between the Diagnostic Tests in African Eyes.

    Science.gov (United States)

    Onwubiko, Stella N; Eze, Boniface I; Udeh, Nnenma N; Onwasigwe, Ernest N; Umeh, Rich E

    2016-11-01

    To assess the concordance between the diagnostic tests for dry eye disease (DED) in a Nigerian hospital population. The study was a hospital-based cross-sectional survey of adults (≥18 years) presenting at the eye clinic of the University of Nigeria Teaching Hospital (UNTH), Enugu; September-December, 2011. Participants' socio-demographic data were collected. Each subject was assessed for DED using the "Ocular Surface Disease Index" (OSDI) questionnaire, tear-film breakup time (TBUT), and Schirmer test. The intertest concordance was assessed using kappa statistic, correlation, and regression coefficients. The participants (n=402; men: 193) were aged 50.1±19.1 standard deviation years (range: 18-94 years). Dry eye disease was diagnosed in 203 by TBUT, 170 by Schirmer test, and 295 by OSDI; the concordance between the tests were OSDI versus TBUT (Kappa, κ=-0.194); OSDI versus Schirmer (κ=-0.276); and TBUT versus Schirmer (κ=0.082). Ocular Surface Disease Index was inversely correlated with Schirmer test (Spearman ρ=-0.231, P<0.001) and TBUT (ρ=-0.237, P<0.001). In the linear regression model, OSDI was poorly predicted by TBUT (β=-0.09; 95% confidence interval (CI): -0.26 to -0.03, P=0.14) and Schirmer test (β=-0.35, 95% CI: -0.53 to -0.18, P=0.18). At UNTH, there is poor agreement, and almost equal correlation, between the subjective and objective tests for DED. Therefore, the selection of diagnostic test for DED should be informed by cost-effectiveness and diagnostic resource availability, not diagnostic efficiency or utility.

  5. Subjective Well-Being, Test Anxiety, Academic Achievement: Testing for Reciprocal Effects

    OpenAIRE

    Steinmayr, Ricarda; Crede, Julia; McElvany, Nele; Wirthwein, Linda

    2016-01-01

    In the context of adolescents’ subjective well-being (SWB), research has recently focused on a number of different school variables. The direction of the relationships between adolescents’ SWB, academic achievement, and test anxiety is, however, still open although reciprocal causation has been hypothesized. The present study set out to investigate to what extent SWB, academic achievement, and test anxiety influence each other over time. A sample of N = 290 11th grade students (n = 138 female...

  6. Genetic test utilization and diagnostic yield in adult patients with neurological disorders.

    Science.gov (United States)

    Bardakjian, Tanya M; Helbig, Ingo; Quinn, Colin; Elman, Lauren B; McCluskey, Leo F; Scherer, Steven S; Gonzalez-Alegre, Pedro

    2018-03-28

    To determine the diagnostic yield of different genetic test modalities in adult patients with neurological disorders, we evaluated all adult patients seen for genetic diagnostic evaluation in the outpatient neurology practice at the University of Pennsylvania between January 2016 and April 2017 as part of the newly created Penn Neurogenetics Program. Subjects were identified through our electronic medical system as those evaluated by the Program's single clinical genetic counselor in that period. A total of 377 patients were evaluated by the Penn Neurogenetics Program in different settings and genetic testing recommended. Of those, 182 (48%) were seen in subspecialty clinic setting and 195 (52%) in a General Neurogenetics Clinic. Genetic testing was completed in over 80% of patients in whom it was recommended. The diagnostic yield was 32% across disease groups. Stratified by testing modality, the yield was highest with directed testing (50%) and array comparative genomic hybridization (45%), followed by gene panels and exome testing (25% each). In conclusion, genetic testing can be successfully requested in clinic in a large majority of adult patients. Age is not a limiting factor for a genetic diagnostic evaluation and the yield of clinical testing across phenotypes (almost 30%) is consistent with previous phenotype-focused or research-based studies. These results should inform the development of specific guidelines for clinical testing and serve as evidence to improve reimbursement by insurance payers.

  7. Diagnostic accuracy of tests to detect Hepatitis C antibody: a meta-analysis and review of the literature.

    Science.gov (United States)

    Tang, Weiming; Chen, Wen; Amini, Ali; Boeras, Debi; Falconer, Jane; Kelly, Helen; Peeling, Rosanna; Varsaneux, Olivia; Tucker, Joseph D; Easterbrook, Philippa

    2017-11-01

    Although direct-acting antivirals can achieve sustained virological response rates greater than 90% in Hepatitis C Virus (HCV) infected persons, at present the majority of HCV-infected individuals remain undiagnosed and therefore untreated. While there are a wide range of HCV serological tests available, there is a lack of formal assessment of their diagnostic performance. We undertook a systematic review and meta-analysis to evaluate he diagnostic accuracy of available rapid diagnostic tests (RDT) and laboratory based EIA assays in detecting antibodies to HCV. We used the PRISMA checklist and Cochrane guidance to develop our search protocol. The search strategy was registered in PROSPERO (CRD42015023567). The search focused on hepatitis C, diagnostic tests, and diagnostic accuracy within eight databases (MEDLINE, EMBASE, the Cochrane Central Register of Controlled Trials, Science Citation Index Expanded, Conference Proceedings Citation Index-Science, SCOPUS, Literatura Latino-Americana e do Caribe em Ciências da Saúde and WHO Global Index Medicus. Studies were included if they evaluated an assay to determine the sensitivity and specificity of HCV antibody (HCV Ab) in humans. Two reviewers independently extracted data and performed a quality assessment of the studies using the QUADAS tool. We pooled test estimates using the DerSimonian-Laird method, by using the software R and RevMan. 5.3. A total of 52 studies were identified that included 52,673 unique test measurements. Based on five studies, the pooled sensitivity and specificity of HCV Ab rapid diagnostic tests (RDTs) were 98% (95% CI 98-100%) and 100% (95% CI 100-100%) compared to an enzyme immunoassay (EIA) reference standard. High HCV Ab RDTs sensitivity and specificity were observed across screening populations (general population, high risk populations, and hospital patients) using different reference standards (EIA, nucleic acid testing, immunoblot). There were insufficient studies to undertake

  8. Efficient Noninferiority Testing Procedures for Simultaneously Assessing Sensitivity and Specificity of Two Diagnostic Tests

    Directory of Open Access Journals (Sweden)

    Guogen Shan

    2015-01-01

    Full Text Available Sensitivity and specificity are often used to assess the performance of a diagnostic test with binary outcomes. Wald-type test statistics have been proposed for testing sensitivity and specificity individually. In the presence of a gold standard, simultaneous comparison between two diagnostic tests for noninferiority of sensitivity and specificity based on an asymptotic approach has been studied by Chen et al. (2003. However, the asymptotic approach may suffer from unsatisfactory type I error control as observed from many studies, especially in small to medium sample settings. In this paper, we compare three unconditional approaches for simultaneously testing sensitivity and specificity. They are approaches based on estimation, maximization, and a combination of estimation and maximization. Although the estimation approach does not guarantee type I error, it has satisfactory performance with regard to type I error control. The other two unconditional approaches are exact. The approach based on estimation and maximization is generally more powerful than the approach based on maximization.

  9. Compounding diagnostic delays: a qualitative study of point-of-care testing in South Africa.

    Science.gov (United States)

    Engel, Nora; Davids, Malika; Blankvoort, Nadine; Pai, Nitika Pant; Dheda, Keertan; Pai, Madhukar

    2015-04-01

    Successful point-of-care (POC) testing (completion of test-and-treat cycle in one patient encounter) has immense potential to reduce diagnostic and treatment delays, and improve patient and public health outcomes. We explored what tests are done and how in public/private, rural/urban hospitals and clinics in South Africa and whether they can ensure successful POC testing. This qualitative research study examined POC testing across major diseases in Cape Town, Durban and Eastern Cape. We conducted 101 semi-structured interviews and seven focus group discussions with doctors, nurses, community health workers, patients, laboratory technicians, policymakers, hospital managers and diagnostic manufacturers. In South Africa, diagnostics are characterised by a centralised system. Most tests conducted on the spot can be made to work successfully as POC tests. The majority of public/private clinics and smaller hospitals send samples via couriers to centralised laboratories and retrieve results the same way, via internet, fax or phone. The main challenge to POC testing lies in transporting samples and results, while delays risk patient loss from diagnostic/treatment pathways. Strategies to deal with associated delays create new problems, such as artificially prolonged turnaround times, strains on human resources and quality of testing, compounding additional diagnostic and treatment delays. For POC testing to succeed, particular characteristics of diagnostic ecosystems and adaptations of professional practices to overcome associated challenges must be taken into account. © 2014 John Wiley & Sons Ltd.

  10. A comparison of rapid diagnostic testing (by plasmodium lactate ...

    African Journals Online (AJOL)

    Background: The World Health Organization (WHO) considers early and rapid diagnosis as one of the strategies to control malaria. This study compared the performance of Quantitative Buffy Coat (QBC) test and the Plasmodium lactate dehydrogenase (pLDH) rapid diagnostic test (RDT) with microscopy as the gold ...

  11. Technology diffusion and diagnostic testing for prostate cancer

    Science.gov (United States)

    Schroeck, Florian R.; Kaufman, Samuel R.; Jacobs, Bruce L.; Skolarus, Ted A.; Miller, David C.; Weizer, Alon Z.; Montgomery, Jeffrey S.; Wei, John T.; Shahinian, Vahakn B.; Hollenbeck, Brent K.

    2013-01-01

    Purpose While the dissemination of robotic prostatectomy and intensity-modulated radiotherapy (IMRT) may fuel increased use of prostatectomy and radiotherapy, these new technologies may also have spillover effects related to diagnostic testing for prostate cancer. Therefore, we examined the association of regional technology penetration with receipt of prostate specific antigen (PSA) testing and prostate biopsy. Methods In this retrospective cohort study, we included 117,857 men age 66 and older from the 5% sample of Medicare beneficiaries living in the Surveillance Epidemiology and End Results (SEER) areas from 2003 – 2007. Regional technology penetration was measured as the number of providers performing robotic prostatectomy or IMRT per population in a healthcare market (i.e., hospital referral region). We assessed the association of technology penetration with rates of PSA testing and prostate biopsy with generalized estimating equations. Results High technology penetration was associated with increased rates of PSA testing (442 versus 425 per 1,000 person-years, pimpact of technology penetration on PSA testing and prostate biopsy was much smaller than the effect of age, race, and comorbidity (e.g., PSA testing rate per 1,000 person-years: 485 versus 373 for men with only one versus 3+ co-morbid conditions, ppenetration was associated with slightly higher rates of PSA testing and no change in prostate biopsy rates. Collectively, our findings temper concerns that adoption of new technology accelerates diagnostic testing for prostate cancer. PMID:23669564

  12. Evaluation of Diagnostic Tests Using Information Theory for Multi-Class Diagnostic Problems and its Application for the Detection of Occlusal Caries Lesions

    Directory of Open Access Journals (Sweden)

    Umut Arslan

    2014-09-01

    Full Text Available Background: Several methods are available to evaluate the performance of the tests when the purpose of the diagnostic test is to discriminate between two possible disease states. However multi-class diagnostic problems frequently appear in many areas of medical science. Hence, there is a need for methods which will enable us to characterize the accuracy of diagnostic tests when there are more than two possible disease states. Aims: To show that two information theory measures, information content (IC and proportional reduction in diagnostic uncertainty (PRDU, can be used for the evaluation of the performance of diagnostic tests for multi-class diagnostic problems that may appear in different areas of medical science. Study Design: Diagnostic accuracy study. Methods: Sixty freshly extracted permanent human molar and premolar teeth suspected to have occlusal caries lesions were selected for the study and were assessed by two experienced examiners. Each examiner performed two evaluations. Histological examination was used as the gold standard. The scores of the histological examination were defined as sound (n=11, enamel caries (n=22 and dentin caries (n=27. Diagnostic performance of i visual inspection, ii radiography, iii laser fluorescence (LF and iv micro-computed tomography (M-CT caries detection methods was evaluated by calculating IC and PRDU. Results: Micro-computed tomography examination was the best method among the diagnostic techniques for the diagnosis of occlusal caries in terms of both IC and PRDU. M-CT examination supplied the maximum diagnostic information about the diagnosis of occlusal caries in the first (IC: 1.056; p<0.05, (PRDU: 70.5% and second evaluation (IC: 1.105; p<0.05, (PRDU: 73.8% for the first examiner. M-CT examination was the best method among the diagnostic techniques for the second examiner in both the first (IC:1.105; p<0.05, (PRDU:73.8% and second evaluation (IC:1.061; p<0.05, (PRDU:70.8%. IC and PRDU were

  13. Cost Implications of Value-Based Pricing for Companion Diagnostic Tests in Precision Medicine.

    Science.gov (United States)

    Zaric, Gregory S

    2016-07-01

    Many interpretations of personalized medicine, also referred to as precision medicine, include discussions of companion diagnostic tests that allow drugs to be targeted to those individuals who are most likely to benefit or that allow treatment to be designed in a way such that individuals who are unlikely to benefit do not receive treatment. Many authors have commented on the clinical and competitive implications of companion diagnostics, but there has been relatively little formal analysis of the cost implications of companion diagnostics, although cost reduction is often cited as a significant benefit of precision medicine. We investigate the potential impact on costs of precision medicine implemented through the use of companion diagnostics. We develop a framework in which the costs of companion diagnostic tests are determined by considerations of profit maximization and cost effectiveness. We analyze four scenarios that are defined by the incremental cost-effectiveness ratio of the new drug in the absence of a companion diagnostic test. We find that, in most scenarios, precision medicine strategies based on companion diagnostics should be expected to lead to increases in costs in the short term and that costs would fall only in a limited number of situations.

  14. Developing and Standardization of a Diagnostic Reading Test

    Directory of Open Access Journals (Sweden)

    Tahereh Sima-Shirazi

    2004-06-01

    Full Text Available Objective: This paper is a report on the development, structure and content of a diagnostic dyslexia reading test. The target population of this test is persian children who have problems in learning reading and may be considered as dyslexic. This diagnostic test is the first reading test developed for the native speakers of persian. Materials & Methods: The theoretical framework of the test is based on two well- established reading tests for the English speaking children, namely Durrell Analysis of Reading and Neale Analysis of Reading Ability. The linguistic content of the subtests is selected from the vocabulary and texts of the textbook used in the primary schools. Both the vocabulary and the sentences of the parrallel passeges were controlled for frequency, phonemic/graphemic regularity, syllable structure, morphology, syntax and semantics. They were also controlled for value judgement by two linguistics and three first grader teachers.The first version of the test is normed on 605 boy and girl first graders from different educational sectors and schools selected randomly.The method used in this research is cross- sectional, descriptive- analytic and the data analysis is based on pearson, and mann-whitney u. Results: Reliability of the test is calculated based on parrallel forms (~ 90% and validity is based on content validity.This test has a supplementary section including spelling, graphem/ phoneme correspondness, nonword reading, irregular word reading, and copy subtests. Conclusion: Considering highreliability and precise validation of the test it can be used to diagnose the dyslexia and related linguistic impairments.

  15. Systematic reviews of diagnostic tests in endocrinology: an audit of methods, reporting, and performance.

    Science.gov (United States)

    Spencer-Bonilla, Gabriela; Singh Ospina, Naykky; Rodriguez-Gutierrez, Rene; Brito, Juan P; Iñiguez-Ariza, Nicole; Tamhane, Shrikant; Erwin, Patricia J; Murad, M Hassan; Montori, Victor M

    2017-07-01

    Systematic reviews provide clinicians and policymakers estimates of diagnostic test accuracy and their usefulness in clinical practice. We identified all available systematic reviews of diagnosis in endocrinology, summarized the diagnostic accuracy of the tests included, and assessed the credibility and clinical usefulness of the methods and reporting. We searched Ovid MEDLINE, EMBASE, and Cochrane CENTRAL from inception to December 2015 for systematic reviews and meta-analyses reporting accuracy measures of diagnostic tests in endocrinology. Experienced reviewers independently screened for eligible studies and collected data. We summarized the results, methods, and reporting of the reviews. We performed subgroup analyses to categorize diagnostic tests as most useful based on their accuracy. We identified 84 systematic reviews; half of the tests included were classified as helpful when positive, one-fourth as helpful when negative. Most authors adequately reported how studies were identified and selected and how their trustworthiness (risk of bias) was judged. Only one in three reviews, however, reported an overall judgment about trustworthiness and one in five reported using adequate meta-analytic methods. One in four reported contacting authors for further information and about half included only patients with diagnostic uncertainty. Up to half of the diagnostic endocrine tests in which the likelihood ratio was calculated or provided are likely to be helpful in practice when positive as are one-quarter when negative. Most diagnostic systematic reviews in endocrine lack methodological rigor, protection against bias, and offer limited credibility. Substantial efforts, therefore, seem necessary to improve the quality of diagnostic systematic reviews in endocrinology.

  16. Model of critical diagnostic reasoning: achieving expert clinician performance.

    Science.gov (United States)

    Harjai, Prashant Kumar; Tiwari, Ruby

    2009-01-01

    Diagnostic reasoning refers to the analytical processes used to determine patient health problems. While the education curriculum and health care system focus on training nurse clinicians to accurately recognize and rescue clinical situations, assessments of non-expert nurses have yielded less than satisfactory data on diagnostic competency. The contrast between the expert and non-expert nurse clinician raises the important question of how differences in thinking may contribute to a large divergence in accurate diagnostic reasoning. This article recognizes superior organization of one's knowledge base, using prototypes, and quick retrieval of pertinent information, using similarity recognition as two reasons for the expert's superior diagnostic performance. A model of critical diagnostic reasoning, using prototypes and similarity recognition, is proposed and elucidated using case studies. This model serves as a starting point toward bridging the gap between clinical data and accurate problem identification, verification, and management while providing a structure for a knowledge exchange between expert and non-expert clinicians.

  17. A general diagnostic model applied to language testing data.

    Science.gov (United States)

    von Davier, Matthias

    2008-11-01

    Probabilistic models with one or more latent variables are designed to report on a corresponding number of skills or cognitive attributes. Multidimensional skill profiles offer additional information beyond what a single test score can provide, if the reported skills can be identified and distinguished reliably. Many recent approaches to skill profile models are limited to dichotomous data and have made use of computationally intensive estimation methods such as Markov chain Monte Carlo, since standard maximum likelihood (ML) estimation techniques were deemed infeasible. This paper presents a general diagnostic model (GDM) that can be estimated with standard ML techniques and applies to polytomous response variables as well as to skills with two or more proficiency levels. The paper uses one member of a larger class of diagnostic models, a compensatory diagnostic model for dichotomous and partial credit data. Many well-known models, such as univariate and multivariate versions of the Rasch model and the two-parameter logistic item response theory model, the generalized partial credit model, as well as a variety of skill profile models, are special cases of this GDM. In addition to an introduction to this model, the paper presents a parameter recovery study using simulated data and an application to real data from the field test for TOEFL Internet-based testing.

  18. Common pitfalls in statistical analysis: Understanding the properties of diagnostic tests - Part 1.

    Science.gov (United States)

    Ranganathan, Priya; Aggarwal, Rakesh

    2018-01-01

    In this article in our series on common pitfalls in statistical analysis, we look at some of the attributes of diagnostic tests (i.e., tests which are used to determine whether an individual does or does not have disease). The next article in this series will focus on further issues related to diagnostic tests.

  19. Diagnostic development and support of MHD (magnetohydrodynamics) test facilities

    Energy Technology Data Exchange (ETDEWEB)

    1989-07-01

    Mississippi State University (MSU) is developing diagnostic instruments for Magnetohydrodynamics (MHD) power train data acquisition and for support of MHD component development test facilities. Microprocessor-controlled optical instruments, initially developed for HRSR support, are being refined, and new systems to measure temperatures and gas-seed-slag stream characteristics are being developed. To further data acquisition and analysis capabilities, the diagnostic systems are being interfaced with MHD Energy Center computers. Technical support for the diagnostic needs of the national MHD research effort is being provided. MSU personnel will also cooperate with government agencies and private industries to improve the transformation of research and development results into processes, products and services applicable to their needs.

  20. The glucose breath test: a diagnostic test for small bowel stricture(s) in Crohn's disease.

    Science.gov (United States)

    Mishkin, Daniel; Boston, Francis M; Blank, David; Yalovsky, Morty; Mishkin, Seymour

    2002-03-01

    The aim of this study was to determine whether an indirect noninvasive indicator of proximal bacterial overgrowth, the glucose breath test, was of diagnostic value in inflammatory bowel disease. Twenty four of 71 Crohn's disease patients tested had a positive glucose breath test. No statistical conclusions could be drawn between the Crohn's disease activity index and glucose breath test status. Of patients with radiologic evidence of small bowel stricture(s), 96.0% had a positive glucose breath test, while only one of 46 negative glucose breath test patients had a stricture. The positive and negative predictive values for a positive glucose breath test as an indicator of stricture formation were 96.0% and 97.8%, respectively. This correlation was not altered in Crohn's disease patients with fistulae or status postresection of the terminal ileum. The data in ulcerative colitis were nondiagnostic. In conclusion, the glucose breath test appears to be an accurate noninvasive inexpensive diagnostic test for small bowel stricture(s) and secondary bacterial overgrowth in Crohn's disease.

  1. 30 CFR 250.520 - When do I have to perform a casing diagnostic test?

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 2 2010-07-01 2010-07-01 false When do I have to perform a casing diagnostic... Operations Casing Pressure Management § 250.520 When do I have to perform a casing diagnostic test? (a) You must perform a casing diagnostic test within 30 days after first observing or imposing casing pressure...

  2. [Pathogenic Mechanism and Diagnostic Testing for Drug Allergies].

    Science.gov (United States)

    Uno, Katsuji

    2018-01-01

     Three stages of the pathogenic mechanism of drug allergies can be considered: antigen formation, immune reaction and inflammation/disorder reaction. Drugs are thought to form 4 types of antigens: drug only, polymers, drug-carrier conjugates, and metabolite-carrier complexes. Antigens are recognized by B cell receptors and T cell receptors. Helper T cells (Th) are differentiated into four subsets, namely, Th1, Th2, Th17 and regulatory T cells (Treg). Th1 produces interleukin (IL)-2 and interferon (IFN)-γ, and activates macrophages and cytotoxic T cells (Tc). Macrophages induce type IV allergies, and Tc lead to serious type IV allergies. On the other hand, Th2 produces IL-4, IL-5, and IL-6, etc., and activates B cells. B cells produce IgE antibodies, and the IgE antibody affects mast cells and induces type I allergies. Activated eosinophil leads to the chronic state of type I allergy. Diagnostic testing for allergenic drugs is necessary for patients with drug allergies. Because in vivo diagnostic tests for allergenic drugs are associated with a risk and burden to the patient, in vitro allergy tests are recommended to identify allergenic drugs. In allergy tests performed in vitro, cytological tests are more effective than serological tests, and the leukocyte migration test (LMT) presently has the highest efficacy. An LMT-chamber is better than LMT-agarose in terms of usability and sensitivity, and it can detect about 80% of allergenic drugs.

  3. Get the Diagnosis: an evidence-based medicine collaborative Wiki for diagnostic test accuracy.

    Science.gov (United States)

    Hammer, Mark M; Kohlberg, Gavriel D

    2017-04-01

    Despite widespread calls for its use, there are challenges to the implementation of evidence-based medicine (EBM) in clinical practice. In response to the challenges of finding timely, pertinent information on diagnostic test accuracy, we developed an online, crowd-sourced Wiki on diagnostic test accuracy called Get the Diagnosis (GTD, http://www.getthediagnosis.org). Since its launch in November 2008 till October 2015, GTD has accumulated information on 300 diagnoses, with 1617 total diagnostic entries. There are a total of 1097 unique diagnostic tests with a mean of 5.4 tests (range 0-38) per diagnosis. 73% of entries (1182 of 1617) have an associated sensitivity and specificity and 89% of entries (1432 of 1617) have associated peer-reviewed literature citations. Altogether, GTD contains 474 unique literature citations. For a sample of three diagnoses, the search precision (percentage of relevant results in the first 30 entries) in GTD was 100% as compared with a range of 13.3%-63.3% for PubMed and between 6.7% and 76.7% for Google Scholar. GTD offers a fast, precise and efficient way to look up diagnostic test accuracy. On three selected examples, GTD had a greater precision rate compared with PubMed and Google Scholar in identifying diagnostic test information. GTD is a free resource that complements other currently available resources. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  4. What is the role of clinical tests and ultrasound in acetabular labral tear diagnostics?

    DEFF Research Database (Denmark)

    Troelsen, Anders; Mechlenburg, Inger; Gelineck, John

    2009-01-01

    BACKGROUND AND PURPOSE: An acetabular labral tear is a diagnostic challenge. Various clinical tests have been described, but little is known about their diagnostic sensitivity and specificity. We investigated the diagnostic validity of clinical tests and ultrasound as compared with MR arthrography...... no or only slight signs of osteoarthritis (Tönnis grade 0-1). RESULTS: MR arthrography identified labral tears in 17 of the 18 hips. Ultrasound had a sensitivity of 94%, a positive predictive value of 94%, and was false negative in only 1 case compared to MR arthrography. The impingement test had the best...... diagnostic ability of the clinical tests, with a sensitivity of 59% and a specificity of 100%. The positive predictive value was 100% while the negative predictive value was 13%. INTERPRETATION: The impingement test is helpful in identifying acetabular labral tears. If this test is negative and if a labral...

  5. Technology diffusion and diagnostic testing for prostate cancer.

    Science.gov (United States)

    Schroeck, Florian R; Kaufman, Samuel R; Jacobs, Bruce L; Skolarus, Ted A; Miller, David C; Weizer, Alon Z; Montgomery, Jeffrey S; Wei, John T; Shahinian, Vahakn B; Hollenbeck, Brent K

    2013-11-01

    While the dissemination of robotic prostatectomy and intensity modulated radiotherapy may fuel the increased use of prostatectomy and radiotherapy, these new technologies may also have spillover effects related to diagnostic testing for prostate cancer. Therefore, we examined the association of regional technology penetration with the receipt of prostate specific antigen testing and prostate biopsy. In this retrospective cohort study we included 117,857 men 66 years old or older from the 5% sample of Medicare beneficiaries living in Surveillance, Epidemiology and End Results (SEER) areas from 2003 to 2007. Regional technology penetration was measured as the number of providers performing robotic prostatectomy or intensity modulated radiotherapy per population in a health care market, ie hospital referral region. We assessed the association of technology penetration with the prostate specific antigen testing rate and prostate biopsy using generalized estimating equations. High technology penetration was associated with an increased rate of prostate specific antigen testing (442 vs 425/1,000 person-years, pimpact of technology penetration on prostate specific antigen testing and prostate biopsy was much less than the effect of age, race and comorbidity, eg the prostate specific antigen testing rate per 1,000 person-years was 485 vs 373 for men with only 1 vs 3+ comorbid conditions (ppenetration is associated with a slightly higher rate of prostate specific antigen testing and no change in the prostate biopsy rate. Collectively, our findings temper concerns that adopting new technology accelerates diagnostic testing for prostate cancer. Copyright © 2013 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  6. Requirements for appropriate evaluation of diagnostic tests in suspected pulmonary embolism

    NARCIS (Netherlands)

    Sanson, B. J.; Meinders, A. J.; Kraaijenhagen, R. A.; van Beek, E. J.; Büller, H. R.

    1999-01-01

    In contrast to the development of new drugs, strict guidelines for the development of new diagnostic methods do not exist. A diagnostic test can be made available without proper evaluation of its clinical utility, which can lead to its premature introduction and inappropriate use. In this review

  7. Beam Diagnostics for the BNL Energy Recovery Linac Test Facility

    International Nuclear Information System (INIS)

    Cameron, Peter; Ben-Zvi, Ilan; Blaskiewicz, Michael; Brennan, Michael; Connolly, Roger; Dawson, William; Degen, Chris; DellaPenna, Al; Gassner, David; Kesselman, Martin; Kewish, Jorg; Litvinenko, Vladimir; Mead, Joseph; Oerter, Brian; Russo, Tom; Vetter, Kurt; Yakimenko, Vitaly

    2004-01-01

    An Energy Recovery Linac (ERL) test facility is presently under construction at BNL. The goals of this test facility are first to demonstrate stable intense CW electron beam with parameters typical for the RHIC e-cooling project (and potentially for eRHIC), second to test novel elements of the ERL (high current CW photo-cathode, superconducting RF cavity with HOM dampers, and feedback systems), and finally to test lattice dependence of stability criteria. Planned diagnostics include position monitors, loss monitors, transverse profile monitors (both optical and wires), scrapers/halo monitors, a high resolution differential current monitor, phase monitors, an energy spread monitor, and a fast transverse monitor (for beam break-up studies and the energy feedback system). We discuss diagnostics challenges that are unique to this project, and present preliminary system specifications. In addition, we include a brief discussion of the timing system

  8. Bovine paratuberculosis: a review of the advantages and disadvantages of different diagnostic tests.

    Science.gov (United States)

    Gilardoni, Liliana R; Paolicchi, Fernando A; Mundo, Silvia L

    2012-01-01

    Paratuberculosis (PTB), or Johne's disease, is a chronic infectious granulomatous enteritis of ruminants, caused by Mycobacterium avium subspecies paratuberculosis (Map). It is characterized by diarrhea and progressive cachexia, which may cause the death of the animal. Calves are the most susceptible to infection. Infected animals excrete Map mainly by the feces. PTB is endemic worldwide, with high prevalence levels, strong economic impact and public health relevance because of its possible association with Crohn's disease. Although the current reference diagnostic test is identification of Map in the bacterial culture, there are different diagnostic tests to identify infected individuals and/or herds. The sensitivity and specificity of these tests vary according to the stage of the disease in the animals to be evaluated. The correct choice and application of each of these diagnostic tests will ensure their success and may allow to establish a control program. The aim of this work is to review and discuss the different diagnostic tests used in the detection of Map-infected animals, focusing on their advantages and disadvantages.

  9. Divergence-based tests for model diagnostic

    Czech Academy of Sciences Publication Activity Database

    Hobza, Tomáš; Esteban, M. D.; Morales, D.; Marhuenda, Y.

    2008-01-01

    Roč. 78, č. 13 (2008), s. 1702-1710 ISSN 0167-7152 R&D Projects: GA MŠk 1M0572 Grant - others:Instituto Nacional de Estadistica (ES) MTM2006-05693 Institutional research plan: CEZ:AV0Z10750506 Keywords : goodness of fit * devergence statistics * GLM * model checking * bootstrap Subject RIV: BB - Applied Statistics, Operational Research Impact factor: 0.445, year: 2008 http://library.utia.cas.cz/separaty/2008/SI/hobza-divergence-based%20tests%20for%20model%20diagnostic.pdf

  10. Real-time remote diagnostic monitoring test-bed in JET

    International Nuclear Information System (INIS)

    Castro, R.; Kneupner, K.; Vega, J.; De Arcas, G.; Lopez, J.M.; Purahoo, K.; Murari, A.; Fonseca, A.; Pereira, A.; Portas, A.

    2010-01-01

    Based on the remote experimentation concept oriented to long pulse shots, a test-bed system has been implemented in JET. Its main functionality is the real-time monitoring, on remote, of a reflectometer diagnostic, to visualize different data outputs and status information. The architecture of the system is formed by: the data generator components, the data distribution system, an access control service, and the client applications. In the test-bed there is one data generator, which is the acquisition equipment associated with the reflectometer diagnostic that generates data and status information. The data distribution system has been implemented using a publishing-subscribing technology that receives data from data generators and redistributes them to client applications. And finally, for monitoring, a client application based on JAVA Web Start technology has been used. There are three interesting results from this project. The first one is the analysis of different aspects (data formats, data frame rate, data resolution, etc) related with remote real-time diagnostic monitoring oriented to long pulse experiments. The second one is the definition and implementation of an architecture, flexible enough to be applied to different types of data generated from other diagnostics, and that fits with remote access requirements. Finally, the third result is a secure system, taking into account internal networks and firewalls aspects of JET, and securing the access from remote users. For this last issue, PAPI technology has been used, enabling access control based on user attributes, enabling mobile users to monitor diagnostics in real-time, and enabling the integration of this service into the EFDA Federation (Castro et al., 2008 ).

  11. Real-time remote diagnostic monitoring test-bed in JET

    Energy Technology Data Exchange (ETDEWEB)

    Castro, R., E-mail: rodrigo.castro@ciemat.e [Asociacion EURATOM/CIEMAT para Fusion, Madrid (Spain); Kneupner, K. [EURATOM/UKAEA Fusion Association, Culham Science Centre, Abingdon, OX14 3DB (United Kingdom); Vega, J. [Asociacion EURATOM/CIEMAT para Fusion, Madrid (Spain); De Arcas, G.; Lopez, J.M. [Universidad Politecnica de Madrid, Grupo I2A2, Madrid (Spain); Purahoo, K. [EURATOM/UKAEA Fusion Association, Culham Science Centre, Abingdon, OX14 3DB (United Kingdom); Murari, A. [Associazione EURATOM-ENEA per la Fusione, Consorzio RFX, 4-35127 Padova (Italy); Fonseca, A. [Associacao EURATOM/IST, Lisbon (Portugal); Pereira, A.; Portas, A. [Asociacion EURATOM/CIEMAT para Fusion, Madrid (Spain)

    2010-07-15

    Based on the remote experimentation concept oriented to long pulse shots, a test-bed system has been implemented in JET. Its main functionality is the real-time monitoring, on remote, of a reflectometer diagnostic, to visualize different data outputs and status information. The architecture of the system is formed by: the data generator components, the data distribution system, an access control service, and the client applications. In the test-bed there is one data generator, which is the acquisition equipment associated with the reflectometer diagnostic that generates data and status information. The data distribution system has been implemented using a publishing-subscribing technology that receives data from data generators and redistributes them to client applications. And finally, for monitoring, a client application based on JAVA Web Start technology has been used. There are three interesting results from this project. The first one is the analysis of different aspects (data formats, data frame rate, data resolution, etc) related with remote real-time diagnostic monitoring oriented to long pulse experiments. The second one is the definition and implementation of an architecture, flexible enough to be applied to different types of data generated from other diagnostics, and that fits with remote access requirements. Finally, the third result is a secure system, taking into account internal networks and firewalls aspects of JET, and securing the access from remote users. For this last issue, PAPI technology has been used, enabling access control based on user attributes, enabling mobile users to monitor diagnostics in real-time, and enabling the integration of this service into the EFDA Federation (Castro et al., 2008 ).

  12. Introducing malaria rapid diagnostic tests in private medicine retail outlets: A systematic literature review.

    Directory of Open Access Journals (Sweden)

    Theodoor Visser

    Full Text Available Many patients with malaria-like symptoms seek treatment in private medicine retail outlets (PMR that distribute malaria medicines but do not traditionally provide diagnostic services, potentially leading to overtreatment with antimalarial drugs. To achieve universal access to prompt parasite-based diagnosis, many malaria-endemic countries are considering scaling up malaria rapid diagnostic tests (RDTs in these outlets, an intervention that may require legislative changes and major investments in supporting programs and infrastructures. This review identifies studies that introduced malaria RDTs in PMRs and examines study outcomes and success factors to inform scale up decisions.Published and unpublished studies that introduced malaria RDTs in PMRs were systematically identified and reviewed. Literature published before November 2016 was searched in six electronic databases, and unpublished studies were identified through personal contacts and stakeholder meetings. Outcomes were extracted from publications or provided by principal investigators.Six published and six unpublished studies were found. Most studies took place in sub-Saharan Africa and were small-scale pilots of RDT introduction in drug shops or pharmacies. None of the studies assessed large-scale implementation in PMRs. RDT uptake varied widely from 8%-100%. Provision of artemisinin-based combination therapy (ACT for patients testing positive ranged from 30%-99%, and was more than 85% in five studies. Of those testing negative, provision of antimalarials varied from 2%-83% and was less than 20% in eight studies. Longer provider training, lower RDT retail prices and frequent supervision appeared to have a positive effect on RDT uptake and provider adherence to test results. Performance of RDTs by PMR vendors was generally good, but disposal of medical waste and referral of patients to public facilities were common challenges.Expanding services of PMRs to include malaria diagnostic

  13. Diagnostic validation of selected serological tests for detecting scrub typhus.

    Science.gov (United States)

    Koraluru, Munegowda; Bairy, Indira; Varma, Muralidhar; Vidyasagar, Sudha

    2015-07-01

    Clinical diagnosis of scrub typhus is often difficult because the symptoms are very similar to those of other febrile illness such as dengue, leptospirosis, malaria and other viral hemorrhagic fevers. Though better diagnostic tests are available for rickettsial diseases and scrub typhus elsewhere, the Weil-Felix test is still commonly used in India, mainly because microimmunofluorescence assays (M-IFA) were not available in India till recently and relevant staff had insufficient training. The present study was performed to investigate the performance of M-IFA, IgM ELISA, and Weil-Felix test on 546 non-repeated serum samples from subjects suspected of having scrub typhus. One hundred and forty-three of these 546 samples were positive by M-IFA; these cases were also confirmed clinically to have scrub typhus based on their dramatic responses to doxycycline therapy. IgM ELISA was positive in 122 of the 143 M-IFA positive cases and the Weil-Felix test in 96. Though the Weil-Felix test is a heterophile agglutination test, it was found in this study to have good specificity but far too little sensitivity to use as a routine diagnostic test. IgM ELISA can be a good substitute for M-IFA. Incorporation of multiple prototype antigens on M-IFA slides is likely one of the reasons for its superior performance. As newer and better diagnostic assays become available for scrub typhus diagnosis in developed countries, it will be imperative to also use such tests in other endemic countries to prevent over- or under-diagnosis of scrub typhus. © 2015 The Societies and Wiley Publishing Asia Pty Ltd.

  14. Diagnostic Accuracy of Obstructive Airway Adult Test for Diagnosis of Obstructive Sleep Apnea.

    Science.gov (United States)

    Gasparini, Giulio; Vicini, Claudio; De Benedetto, Michele; Salamanca, Fabrizio; Sorrenti, Giovanni; Romandini, Mario; Bosi, Marcello; Saponaro, Gianmarco; Foresta, Enrico; Laforì, Andreina; Meccariello, Giuseppe; Bianchi, Alessandro; Toraldo, Domenico Maurizio; Campanini, Aldo; Montevecchi, Filippo; Rizzotto, Grazia; Cervelli, Daniele; Moro, Alessandro; Arigliani, Michele; Gobbi, Riccardo; Pelo, Sandro

    2015-01-01

    The gold standard for the diagnosis of Obstructive Sleep Apnea (OSA) is polysomnography, whose access is however reduced by costs and limited availability, so that additional diagnostic tests are needed. To analyze the diagnostic accuracy of the Obstructive Airway Adult Test (OAAT) compared to polysomnography for the diagnosis of OSA in adult patients. Ninety patients affected by OSA verified with polysomnography (AHI ≥ 5) and ten healthy patients, randomly selected, were included and all were interviewed by one blind examiner with OAAT questions. The Spearman rho, evaluated to measure the correlation between OAAT and polysomnography, was 0.72 (p diagnostic accuracy for the diagnosis of OSA. It has also been shown to be able to discriminate among the different degrees of severity of OSA. Additional large studies aiming to validate this questionnaire as a screening or diagnostic test are needed.

  15. Diagnostic accuracy of physical examination tests of the ankle/foot complex: a systematic review.

    Science.gov (United States)

    Schwieterman, Braun; Haas, Deniele; Columber, Kirby; Knupp, Darren; Cook, Chad

    2013-08-01

    Orthopedic special tests of the ankle/foot complex are routinely used during the physical examination process in order to help diagnose ankle/lower leg pathologies. The purpose of this systematic review was to investigate the diagnostic accuracy of ankle/lower leg special tests. A search of the current literature was conducted using PubMed, CINAHL, SPORTDiscus, ProQuest Nursing and Allied Health Sources, Scopus, and Cochrane Library. Studies were eligible if they included the following: 1) a diagnostic clinical test of musculoskeletal pathology in the ankle/foot complex, 2) description of the clinical test or tests, 3) a report of the diagnostic accuracy of the clinical test (e.g. sensitivity and specificity), and 4) an acceptable reference standard for comparison. The quality of included studies was determined by two independent reviewers using the Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) tool. Nine diagnostic accuracy studies met the inclusion criteria for this systematic review; analyzing a total of 16 special tests of the ankle/foot complex. After assessment using the QUADAS-2, only one study had low risk of bias and low concerns regarding applicability. Most ankle/lower leg orthopedic special tests are confirmatory in nature and are best utilized at the end of the physical examination. Most of the studies included in this systematic review demonstrate notable biases, which suggest that results and recommendations in this review should be taken as a guide rather than an outright standard. There is need for future research with more stringent study design criteria so that more accurate diagnostic power of ankle/lower leg special tests can be determined. 3a.

  16. Integrated Rapid-Diagnostic-Test Reader Platform on a Cellphone

    Science.gov (United States)

    Mudanyali, Onur; Dimitrov, Stoyan; Sikora, Uzair; Padmanabhan, Swati; Navruz, Isa; Ozcan, Aydogan

    2012-01-01

    We demonstrate a cellphone based Rapid-Diagnostic-Test (RDT) reader platform that can work with various lateral flow immuno-chromatographic assays and similar tests to sense the presence of a target analyte in a sample. This compact and cost-effective digital RDT reader, weighing only ~65 grams, mechanically attaches to the existing camera unit of a cellphone, where various types of RDTs can be inserted to be imaged in reflection or transmission modes under light-emitting-diode (LED) based illumination. Captured raw images of these tests are then digitally processed (within less than 0.2 sec/image) through a smart application running on the cellphone for validation of the RDT as well as for automated reading of its diagnostic result. The same smart application running on the cellphone then transmits the resulting data, together with the RDT images and other related information (e.g., demographic data) to a central server, which presents the diagnostic results on a world-map through geo-tagging. This dynamic spatio-temporal map of various RDT results can then be viewed and shared using internet browsers or through the same cellphone application. We tested this platform using malaria, tuberculosis (TB) as well as HIV RDTs by installing it on both Android based smart-phones as well as an iPhone. Providing real-time spatio-temporal statistics for the prevalence of various infectious diseases, this smart RDT reader platform running on cellphones might assist health-care professionals and policy makers to track emerging epidemics worldwide and help epidemic preparedness. PMID:22596243

  17. A comparison of diagnostic tests for lactose malabsorption - which one is the best?

    Directory of Open Access Journals (Sweden)

    Hovde Øistein

    2009-10-01

    Full Text Available Abstract Background Perceived milk intolerance is a common complaint, and tests for lactose malabsorption (LM are unreliable. This study assesses the agreement between diagnostic tests for LM and describes the diagnostic properties of the tests. Methods Patients above 18 years of age with suspected LM were included. After oral intake of 25 g lactose, a combined test with measurement of serum glucose (s-glucose and hydrogen (H2 and methane (CH4 in expired air was performed and symptoms were recorded. In patients with discrepancies between the results, the combined test was repeated and a gene test for lactose non-persistence was added. The diagnosis of LM was based on an evaluation of all tests. The following tests were compared: Increase in H2, CH4, H2+CH4 and H2+CH4x2 in expired air, increase in s-glucose, and symptoms. The agreement was calculated and the diagnostic properties described. Results Sixty patients were included, seven (12% had LM. The agreement (kappa-values between the methods varied from 0.25 to 0.91. The best test was the lactose breath test with measurement of the increase in H2 + CH4x2 in expired air. With a cut-off level Conclusion The agreement between commonly used methods for the diagnosis of LM was unsatisfactory. A lactose breath test with measurement of H2 + CH4x2 in expired air had the best diagnostic properties.

  18. Evaluating the accuracy of molecular diagnostic testing for canine visceral leishmaniasis using latent class analysis.

    Directory of Open Access Journals (Sweden)

    Manuela da Silva Solcà

    Full Text Available Host tissues affected by Leishmania infantum have differing degrees of parasitism. Previously, the use of different biological tissues to detect L. infantum DNA in dogs has provided variable results. The present study was conducted to evaluate the accuracy of molecular diagnostic testing (qPCR in dogs from an endemic area for canine visceral leishmaniasis (CVL by determining which tissue type provided the highest rate of parasite DNA detection. Fifty-one symptomatic dogs were tested for CVL using serological, parasitological and molecular methods. Latent class analysis (LCA was performed for accuracy evaluation of these methods. qPCR detected parasite DNA in 100% of these animals from at least one of the following tissues: splenic and bone marrow aspirates, lymph node and skin fragments, blood and conjunctival swabs. Using latent variable as gold standard, the qPCR achieved a sensitivity of 95.8% (CI 90.4-100 in splenic aspirate; 79.2% (CI 68-90.3 in lymph nodes; 77.3% (CI 64.5-90.1 in skin; 75% (CI 63.1-86.9 in blood; 50% (CI 30-70 in bone marrow; 37.5% (CI 24.2-50.8 in left-eye; and 29.2% (CI 16.7-41.6 in right-eye conjunctival swabs. The accuracy of qPCR using splenic aspirates was further evaluated in a random larger sample (n = 800, collected from dogs during a prevalence study. The specificity achieved by qPCR was 76.7% (CI 73.7-79.6 for splenic aspirates obtained from the greater sample. The sensitivity accomplished by this technique was 95% (CI 93.5-96.5 that was higher than those obtained for the other diagnostic tests and was similar to that observed in the smaller sampling study. This confirms that the splenic aspirate is the most effective type of tissue for detecting L. infantum infection. Additionally, we demonstrated that LCA could be used to generate a suitable gold standard for comparative CVL testing.

  19. The role of molecular diagnostic testing in the management of thyroid nodules.

    Science.gov (United States)

    Moore, Maureen D; Panjwani, Suraj; Gray, Katherine D; Finnerty, Brendan M; Zarnegar, Rasa; Fahey, Thomas J

    2017-06-01

    Fine needle aspiration (FNA) with cytologic examination remains the standard of care for investigation of thyroid nodules. However, as many as 30% of FNA samples are cytologically indeterminate for malignancy, which confounds clinical management. To reduce the burden of repeat diagnostic testing and unnecessary surgery, there has been extensive investigation into molecular markers that can be detected on FNA specimens to more accurately stratify a patient's risk of malignancy. Areas covered: In this review, the authors discuss recent evidence and progress in molecular markers used in the diagnosis of thyroid cancer highlighting somatic gene alterations, molecular technologies and microRNA analysis. Expert commentary: The goal of molecular markers is to improve diagnostic accuracy and aid clinicians in the preoperative management of thyroid lesions. Modalities such as direct mutation analysis, mRNA gene expression profiling, next-generation sequencing, and miRNA expression profiling have been explored to improve the diagnostic accuracy of thyroid nodule FNA. Although no perfect test has been discovered, molecular diagnostic testing has revolutionized the management of thyroid nodules.

  20. Concordance in diagnostic testing for respiratory pathogens of bighorn sheep

    Science.gov (United States)

    Walsh, Daniel P.; Cassirer, E. Frances; Bonds, Michael D.; Brown, Daniel R.; Edwards, William H.; Weiser, Glen C.; Drew, Mark L.; Briggs, Robert E.; Fox, Karen A.; Miller, Michael W.; Shanthalingam, Sudarvili; Srikumaran, Subramaniam; Besser, Thomas E.

    2016-01-01

    Reliable diagnostic tests are essential for disease investigation and management. This is particularly true for diseases of free-ranging wildlife where sampling is logistically difficult precluding retesting. Clinical assays for wildlife diseases frequently vary among laboratories because of lack of appropriate standardized commercial kits. Results of diagnostic testing may also be called into question when investigators report different etiologies for disease outbreaks, despite similar clinical and pathologic findings. To evaluate reliability of diagnostic testing for respiratory pathogens of bighorn sheep (Ovis canadensis), we conducted a series of ring tests across 6 laboratories routinely involved in detection of Mycoplasma ovipneumoniae, Pasteurellaceae, lktA (the Pasteurellaceae gene encoding leukotoxin), and 3 reference laboratories. Consistency of results for replicate samples within laboratories was high (median agreement = 1.0). Agreement between laboratories was high for polymerase chain reaction (PCR) detection of M. ovipneumoniae and culture isolation of Mannheimia spp. and Bibersteinia trehalosi(median agreement = 0.89–0.95, Kappa = 0.65–0.74), and lower for PCR detection of Mannheimiaspp. lktA (median agreement = 0.58, Kappa = 0.12). Most errors on defined status samples were false negatives, suggesting test sensitivity was a greater problem than specificity. However, tests for M. haemolytica and lktA yielded some false positive results. Despite differences in testing protocols, median agreement among laboratories and correct classification of controls for most agents was ≥0.80, meeting or exceeding the standard required by federal proficiency testing programs. This information is valuable for interpreting test results, laboratory quality assessments, and advancing diagnosis of respiratory disease in wild sheep. Published 2016. This article is a U.S. Government work and is in the public domain in the USA.

  1. A systematic review of the diagnostic performance of orthopedic physical examination tests of the hip.

    Science.gov (United States)

    Rahman, Labib Ataur; Adie, Sam; Naylor, Justine Maree; Mittal, Rajat; So, Sarah; Harris, Ian Andrew

    2013-08-30

    Previous reviews of the diagnostic performances of physical tests of the hip in orthopedics have drawn limited conclusions because of the low to moderate quality of primary studies published in the literature. This systematic review aims to build on these reviews by assessing a broad range of hip pathologies, and employing a more selective approach to the inclusion of studies in order to accurately gauge diagnostic performance for the purposes of making recommendations for clinical practice and future research. It specifically identifies tests which demonstrate strong and moderate diagnostic performance. A systematic search of Medline, Embase, Embase Classic and CINAHL was conducted to identify studies of hip tests. Our selection criteria included an analysis of internal and external validity. We reported diagnostic performance in terms of sensitivity, specificity, predictive values and likelihood ratios. Likelihood ratios were used to identify tests with strong and moderate diagnostic utility. Only a small proportion of tests reported in the literature have been assessed in methodologically valid primary studies. 16 studies were included in our review, producing 56 independent test-pathology combinations. Two tests demonstrated strong clinical utility, the patellar-pubic percussion test for excluding radiologically occult hip fractures (negative LR 0.05, 95% Confidence Interval [CI] 0.03-0.08) and the hip abduction sign for diagnosing sarcoglycanopathies in patients with known muscular dystrophies (positive LR 34.29, 95% CI 10.97-122.30). Fifteen tests demonstrated moderate diagnostic utility for diagnosing and/or excluding hip fractures, symptomatic osteoarthritis and loosening of components post-total hip arthroplasty. We have identified a number of tests demonstrating strong and moderate diagnostic performance. These findings must be viewed with caution as there are concerns over the methodological quality of the primary studies from which we have extracted our

  2. Modeling Complex Workflow in Molecular Diagnostics

    Science.gov (United States)

    Gomah, Mohamed E.; Turley, James P.; Lu, Huimin; Jones, Dan

    2010-01-01

    One of the hurdles to achieving personalized medicine has been implementing the laboratory processes for performing and reporting complex molecular tests. The rapidly changing test rosters and complex analysis platforms in molecular diagnostics have meant that many clinical laboratories still use labor-intensive manual processing and testing without the level of automation seen in high-volume chemistry and hematology testing. We provide here a discussion of design requirements and the results of implementation of a suite of lab management tools that incorporate the many elements required for use of molecular diagnostics in personalized medicine, particularly in cancer. These applications provide the functionality required for sample accessioning and tracking, material generation, and testing that are particular to the evolving needs of individualized molecular diagnostics. On implementation, the applications described here resulted in improvements in the turn-around time for reporting of more complex molecular test sets, and significant changes in the workflow. Therefore, careful mapping of workflow can permit design of software applications that simplify even the complex demands of specialized molecular testing. By incorporating design features for order review, software tools can permit a more personalized approach to sample handling and test selection without compromising efficiency. PMID:20007844

  3. Quality of information accompanying on-line marketing of home diagnostic tests.

    Science.gov (United States)

    Datta, Adrija K; Selman, Tara J; Kwok, Tony; Tang, Teresa; Khan, Khalid S

    2008-01-01

    To assess the quality of information provided to consumers by websites marketing medical home diagnostic tests. A cross-sectional analysis of a database developed from searching targeted websites. Data sources were websites written in English which marketed medical home diagnostic tests. A meta-search engine was used to identify the first 20 citations for each type of home diagnostic medical test. Relevant websites limited to those written in English were reviewed independently and in triplicate, with disputes resolved by two further reviewers. Information on the quality of these sites was extracted using a pre-piloted performer. 168 websites were suitable for inclusion in the review. The quality of these sites showed marked variation. Only 24 of 168 (14.2%) complied with at least three-quarters of the quality items and just over half (95 of 168, 56.5%) reported official approval or certification of the test. Information on accuracy of the test marketed was reported by 87 of 168 (51.7%) websites, with 15 of 168 (8.9%) providing a scientific reference. Instructions for use of the product were found in 97 of 168 (57.9%). However, the course of action to be taken after obtaining the test result was stated in only 63 of 168 (37.5%) for a positive result and 43 of 168 (25.5%) for a negative result. The quality of information posted on commercial websites marketing home tests online is unsatisfactory and potentially misleading for consumers.

  4. Evidence Based Medicine; Positive and Negative Likelihood Ratios of Diagnostic Tests

    Directory of Open Access Journals (Sweden)

    Alireza Baratloo

    2015-10-01

    Full Text Available In the previous two parts of educational manuscript series in Emergency, we explained some screening characteristics of diagnostic tests including accuracy, sensitivity, specificity, and positive and negative predictive values. In the 3rd  part we aimed to explain positive and negative likelihood ratio (LR as one of the most reliable performance measures of a diagnostic test. To better understand this characteristic of a test, it is first necessary to fully understand the concept of sensitivity and specificity. So we strongly advise you to review the 1st part of this series again. In short, the likelihood ratios are about the percentage of people with and without a disease but having the same test result. The prevalence of a disease can directly influence screening characteristics of a diagnostic test, especially its sensitivity and specificity. Trying to eliminate this effect, LR was developed. Pre-test probability of a disease multiplied by positive or negative LR can estimate post-test probability. Therefore, LR is the most important characteristic of a test to rule out or rule in a diagnosis. A positive likelihood ratio > 1 means higher probability of the disease to be present in a patient with a positive test. The further from 1, either higher or lower, the stronger the evidence to rule in or rule out the disease, respectively. It is obvious that tests with LR close to one are less practical. On the other hand, LR further from one will have more value for application in medicine. Usually tests with 0.1 < LR > 10 are considered suitable for implication in routine practice.

  5. The dilemma of diagnostic testing for Prader-Willi syndrome

    Science.gov (United States)

    Hung, Dorothy

    2017-01-01

    Although Prader-Willi syndrome (PWS) is a well-described clinical dysmorphic syndrome, DNA testing is required for a definitive diagnosis. A definitive diagnosis can be made in approximately 99% of cases using DNA testing; there are a number of DNA tests that can be used for this purpose, although there is no set standard algorithm of testing. The dilemma arises because of the complex genetic mechanisms at the basis of PWS, which need to be elucidated. To establish the molecular mechanism with a complete work up, involves at least 2 tests. Here we discuss the commonly used tests currently available and suggest a cost—effective approach to diagnostic testing. PMID:28164030

  6. Diagnostic accuracy of the Thessaly test, standardised clinical history and other clinical examination tests (Apley's, McMurray's and joint line tenderness) for meniscal tears in comparison with magnetic resonance imaging diagnosis.

    Science.gov (United States)

    Blyth, Mark; Anthony, Iain; Francq, Bernard; Brooksbank, Katriona; Downie, Paul; Powell, Andrew; Jones, Bryn; MacLean, Angus; McConnachie, Alex; Norrie, John

    2015-08-01

    Reliable non-invasive diagnosis of meniscal tears is difficult. Magnetic resonance imaging (MRI) is often used but is expensive and incidental findings are problematic. There are a number of physical examination tests for the diagnosis of meniscal tears that are simple, cheap and non-invasive. To determine the diagnostic accuracy of the Thessaly test and to determine if the Thessaly test (alone or in combination with other physical tests) can obviate the need for further investigation by MRI or arthroscopy for patients with a suspected meniscal tear. Single-centre prospective diagnostic accuracy study. Although the study was performed in a secondary care setting, it was designed to replicate the results that would have been achieved in a primary care setting. Two cohorts of patients were recruited: patients with knee pathology (n = 292) and a control cohort with no knee pathology (n = 75). Sensitivity, specificity and diagnostic accuracy of the Thessaly test in determining the presence of meniscal tears. Participants were assessed by both a primary care clinician and a musculoskeletal clinician. Both clinicians performed the Thessaly test, McMurray's test, Apley's test, joint line tenderness test and took a standardised clinical history from the patient. The Thessaly test had a sensitivity of 0.66, a specificity of 0.39 and a diagnostic accuracy of 54% when utilised by primary care clinicians. This compared with a sensitivity of 0.62, a specificity of 0.55 and diagnostic accuracy of 59% when used by musculoskeletal clinicians. The diagnostics accuracy of the other tests when used by primary care clinicians was 54% for McMurray's test, 53% for Apley's test, 54% for the joint line tenderness test and 55% for clinical history. For primary care clinicians, age and past history of osteoarthritis were both significant predictors of MRI diagnosis of meniscal tears. For musculoskeletal clinicians age and a positive diagnosis of meniscal tears on clinical history

  7. Systematic review, meta-analysis and economic modelling of molecular diagnostic tests for antibiotic resistance in tuberculosis.

    Science.gov (United States)

    Drobniewski, Francis; Cooke, Mary; Jordan, Jake; Casali, Nicola; Mugwagwa, Tendai; Broda, Agnieszka; Townsend, Catherine; Sivaramakrishnan, Anand; Green, Nathan; Jit, Mark; Lipman, Marc; Lord, Joanne; White, Peter J; Abubakar, Ibrahim

    2015-05-01

    introducing rapid molecular testing (in addition to culture and drug sensitivity testing). Probabilistic sensitivity analysis was performed to evaluate the impact on cost-effectiveness of diagnostic and treatment time delays, diagnosis and treatment costs, and associated QALYs. A total of 8922 titles and abstracts were identified, with 557 papers being potentially eligible. Of these, 56 studies contained sufficient test information for analysis. All three commercial tests performed well when detecting drug resistance in clinical samples, although with evidence of heterogeneity between studies. Pooled sensitivity for GenoType® MTBDRplus (Hain Lifescience, Nehren, Germany) (isoniazid and rifampicin resistance), INNO-LiPA Rif.TB® (Fujirebio Europe, Ghent, Belgium) (rifampicin resistance) and Xpert® MTB/RIF (Cepheid Inc., Sunnyvale, CA, USA) (rifampicin resistance) was 83.4%, 94.6%, 95.4% and 96.8%, respectively; equivalent pooled specificity was 99.6%, 98.2%, 99.7% and 98.4%, respectively. Results of the transmission model suggest that all of the rapid assays considered here, if added to the current diagnostic pathway, would be cost-saving and achieve a reduction in expected QALY loss compared with current practice. GenoType MTBDRplus appeared to be the most cost-effective of the rapid tests in the South Asian population, although results were similar for GeneXpert. In all other scenarios GeneXpert appeared to be the most cost-effective strategy. Rapid molecular tests for rifampicin and isoniazid resistance were sensitive and specific. They may also be cost-effective when added to culture drug susceptibility testing in the UK. There is global interest in point-of-care testing and further work is needed to review the performance of emerging tests and the wider health-economic impact of decentralised testing in clinics and primary care, as well as non-health-care settings, such as shelters and prisons. This study is registered as PROSPERO CRD42011001537. The National Institute

  8. Systematic review, meta-analysis and economic modelling of molecular diagnostic tests for antibiotic resistance in tuberculosis.

    Science.gov (United States)

    Drobniewski, Francis; Cooke, Mary; Jordan, Jake; Casali, Nicola; Mugwagwa, Tendai; Broda, Agnieszka; Townsend, Catherine; Sivaramakrishnan, Anand; Green, Nathan; Jit, Mark; Lipman, Marc; Lord, Joanne; White, Peter J; Abubakar, Ibrahim

    2015-01-01

    economic model was used to evaluate the cost-effectiveness of introducing rapid molecular testing (in addition to culture and drug sensitivity testing). Probabilistic sensitivity analysis was performed to evaluate the impact on cost-effectiveness of diagnostic and treatment time delays, diagnosis and treatment costs, and associated QALYs. RESULTS A total of 8922 titles and abstracts were identified, with 557 papers being potentially eligible. Of these, 56 studies contained sufficient test information for analysis. All three commercial tests performed well when detecting drug resistance in clinical samples, although with evidence of heterogeneity between studies. Pooled sensitivity for GenoType® MTBDRplus (Hain Lifescience, Nehren, Germany) (isoniazid and rifampicin resistance), INNO-LiPA Rif.TB® (Fujirebio Europe, Ghent, Belgium) (rifampicin resistance) and Xpert® MTB/RIF (Cepheid Inc., Sunnyvale, CA, USA) (rifampicin resistance) was 83.4%, 94.6%, 95.4% and 96.8%, respectively; equivalent pooled specificity was 99.6%, 98.2%, 99.7% and 98.4%, respectively. Results of the transmission model suggest that all of the rapid assays considered here, if added to the current diagnostic pathway, would be cost-saving and achieve a reduction in expected QALY loss compared with current practice. GenoType MTBDRplus appeared to be the most cost-effective of the rapid tests in the South Asian population, although results were similar for GeneXpert. In all other scenarios GeneXpert appeared to be the most cost-effective strategy. CONCLUSIONS Rapid molecular tests for rifampicin and isoniazid resistance were sensitive and specific. They may also be cost-effective when added to culture drug susceptibility testing in the UK. There is global interest in point-of-care testing and further work is needed to review the performance of emerging tests and the wider health-economic impact of decentralised testing in clinics and primary care, as well as non-health-care settings, such as shelters and

  9. Receiver operating characteristic (ROC) curves and the definition of threshold levels to diagnose coronary artery disease on electrocardiographic stress testing. Part I: The use of ROC curves in diagnostic medicine and electrocardiographic markers of ischaemia.

    Science.gov (United States)

    Barnabei, Luca; Marazìa, Stefania; De Caterina, Raffaele

    2007-11-01

    A common problem in diagnostic medicine, when performing a diagnostic test, is to obtain an accurate discrimination between 'normal' cases and cases with disease, owing to the overlapping distributions of these populations. In clinical practice, it is exceedingly rare that a chosen cut point will achieve perfect discrimination between normal cases and those with disease, and one has to select the best compromise between sensitivity and specificity by comparing the diagnostic performance of different tests or diagnostic criteria available. Receiver operating characteristic (or receiver operator characteristic, ROC) curves allow systematic and intuitively appealing descriptions of the diagnostic performance of a test and a comparison of the performance of different tests or diagnostic criteria. This review will analyse the basic principles underlying ROC curves and their specific application to the choice of optimal parameters on exercise electrocardiographic (ECG) stress testing. Part I will focus on theoretical description and analysis along with reviewing the common problems related to the diagnosis of myocardial ischaemia by means of exercise ECG stress testing. Part II will be devoted to applying ROC curves to available diagnostic criteria through the analysis of ECG stress test parameters.

  10. The Evaluation of Diagnostic Tests for Sexually Transmitted Infections

    Directory of Open Access Journals (Sweden)

    Max A Chernesky

    2005-01-01

    Full Text Available Diagnostic tests should receive method- and use-effectiveness evaluations. Method-effectiveness evaluations determine sensitivity, specificity and predictive values for new tests. Use-effectiveness evaluations determine how practical or convenient a new test will be in a specific setting and may not be performed in a formal way in North American laboratories. To perform a clinical method evaluation of diagnostic tests, a good relationship between laboratory and clinical personnel is essential. Studies are usually conducted separately on populations of men and women, and should include sampling from different prevalence groups. Test performance comparisons may be made on a single specimen type or on more than one specimen from the same patient, which allows for the expansion of a reference standard and includes the ability of a particular assay, performed on a specimen type to diagnose an infected individual. The following components of the evaluation should be standardized and carefully followed: specimen identification; collection; transportation; processing; quality control; reading; proficiency testing; confirmatory testing; discordant analysis -- sensitivity, specificity and predictive value calculations; and record keeping. Methods are available to determine whether sample results are true or false positives or negatives. Use-effectiveness evaluations might determine the stability or durability of supplies and equipment; the logistics of shipping, receiving and storing supplies; the clarity and completeness of test instructions; the time and effort required to process and read results; the subjectivity factors in interpretation and reporting; and the costs. These determinations are usually more apparent for commercial assays than for homemade tests.

  11. Testing for Chronic Diarrhea.

    Science.gov (United States)

    Raman, M

    Chronic diarrhea is a frequently encountered symptom in clinical practice. The etiologies for chronic diarrhea are diverse and broad with varying clinical implications. A useful method of categorizing chronic diarrhea to guide a diagnostic work-up is a pathophysiology-based framework. Chronic diarrhea may be categorized as malabsorptive, secretory, osmotic, and inflammatory or motility related. Frequently, overlap between categories may exist for any given diarrhea etiology and diagnostic testing must occur with an understanding of the differential diagnosis. Investigations to achieve a diagnosis for chronic diarrhea range from screening blood and stool tests to more directed testing such as diagnostic imaging, and endoscopic and histological evaluation. The pathophysiology-based framework proposed in this chapter will allow the clinician to select screening tests followed by targeted tests to minimize cost and complications to the patient, while providing a highly effective method to achieve an accurate diagnosis. © 2017 Elsevier Inc. All rights reserved.

  12. Diagnostic Tests for Entering and Departing Undergraduate Students

    Science.gov (United States)

    Waltham, Chris; Kotlicki, A.

    2006-12-01

    A diagnostic test administered at the start of a class should test basic concepts which are recognized as course prerequisites. The questions should not be over-packaged: e.g. students should be required to create models, rather than this being done for them each time. Students should be allowed great latitude in their answers, so we can discover what they are thinking. When administered at the end of a class the goals should be similar: testing concepts taught in the class itself and the retention of necessary concepts from previous classes. Great care has to be taken to avoid teaching to the test. In assessing an entire program, for example an undergraduate majors degree in physics, then one looks for very general skills and knowledge not specific to any one course. The purpose of an undergraduate degree in physics (or indeed any science) is to equip the students with a set of problem-solving skills and basic knowledge which can be applied in a large variety of workplace settings and to allow that student to contribute to civic society as a science-literate person. The creator of any diagnostic test should always have these big goals in mind. We have developed a set of questions which we think fulfill these criteria, yet are not specific to any particular level of science education. They have been administered to students in secondary schools across Canada, incoming first-year science students and final-year physics students at the University of British Columbia. The results will be presented.

  13. Achieving successful evidence-based practice implementation in juvenile justice: The importance of diagnostic and evaluative capacity.

    Science.gov (United States)

    Walker, Sarah Cusworth; Bumbarger, Brian K; Phillippi, Stephen W

    2015-10-01

    Evidence-based programs (EBPs) are an increasingly visible aspect of the treatment landscape in juvenile justice. Research demonstrates that such programs yield positive returns on investment and are replacing more expensive, less effective options. However, programs are unlikely to produce expected benefits when they are not well-matched to community needs, not sustained and do not reach sufficient reach and scale. We argue that achieving these benchmarks for successful implementation will require states and county governments to invest in data-driven decision infrastructure in order to respond in a rigorous and flexible way to shifting political and funding climates. We conceptualize this infrastructure as diagnostic capacity and evaluative capacity: Diagnostic capacity is defined as the process of selecting appropriate programing and evaluative capacity is defined as the ability to monitor and evaluate progress. Policy analyses of Washington State, Pennsylvania and Louisiana's program implementation successes are used to illustrate the benefits of diagnostic and evaluate capacity as a critical element of EBP implementation. Copyright © 2015 Elsevier Ltd. All rights reserved.

  14. Beyond the 2×2 -contingency table: a primer on entropies and mutual information in various scenarios involving m diagnostic categories and n categories of diagnostic tests.

    Science.gov (United States)

    Reibnegger, Gilbert

    2013-10-21

    Usual evaluation tools for diagnostic tests such as, sensitivity/specificity and ROC analyses, are designed for the discrimination between two diagnostic categories, using dichotomous test results. Information theoretical quantities such as mutual information allow in depth-analysis of more complex discrimination problems, including continuous test results, but are rarely used in clinical chemistry. This paper provides a primer on useful information theoretical concepts with a strong focus on typical diagnostic scenarios. Information theoretical concepts are shortly explained. Mathematica CDF documents are provided which compute entropies and mutual information as function of pretest probabilities and the distribution of test results among the categories, and allow interactive exploration of the behavior of these quantities in comparison with more conventional diagnostic measures. Using data from a previously published study, the application of information theory to practical diagnostic problems involving up to 4×4 -contingency tables is demonstrated. Information theoretical concepts are particularly useful for diagnostic problems requiring more than the usual binary classification. Quantitative test results can be properly analyzed, and in contrast to popular concepts such as ROC analysis, the effects of variations of pre-test probabilities of the diagnostic categories can be explicitly taken into account. © 2013 Elsevier B.V. All rights reserved.

  15. Identification student’s misconception of heat and temperature using three-tier diagnostic test

    Science.gov (United States)

    Suliyanah; Putri, H. N. P. A.; Rohmawati, L.

    2018-03-01

    The objective of this research is to develop a Three-Tier Diagnostic Test (TTDT) to identify the student's misconception of heat and temperature. Stages of development include: analysis, planning, design, development, evaluation and revise. The results of this study show that (1) the quality of the three-tier type diagnostic test instrument developed has been expressed well with the following details: (a) Internal validity of 88.19% belonging to the valid category. (b) External validity of empirical construct validity test using Pearson Product Moment obtained 0.43 is classified and result of empirical construct validity test obtained false positives 6.1% and false negatives 5.9% then the instrument was valid. (c) Test reliability by using Cronbach’s Alpha of 0.98 which means acceptable. (d) The 80% difficulty level test is quite difficult. (2) Student misconceptions on the temperature of heat and displacement materials based on the II test the highest (84%), the lowest (21%), and the non-misconceptions (7%). (3) The highest cause of misconception among students is associative thinking (22%) and the lowest is caused by incomplete or incomplete reasoning (11%). Three-Tier Diagnostic Test (TTDT) could identify the student's misconception of heat and temperature.

  16. Quality of information accompanying on-line marketing of home diagnostic tests

    Science.gov (United States)

    Datta, Adrija K; Selman, Tara J; Kwok, Tony; Tang, Teresa; Khan, Khalid S

    2008-01-01

    Objective To assess the quality of information provided to consumers by websites marketing medical home diagnostic tests. Design A cross-sectional analysis of a database developed from searching targeted websites. Setting Data sources were websites written in English which marketed medical home diagnostic tests. Main outcome measures A meta-search engine was used to identify the first 20 citations for each type of home diagnostic medical test. Relevant websites limited to those written in English were reviewed independently and in triplicate, with disputes resolved by two further reviewers. Information on the quality of these sites was extracted using a pre-piloted performer. Results 168 websites were suitable for inclusion in the review. The quality of these sites showed marked variation. Only 24 of 168 (14.2%) complied with at least three-quarters of the quality items and just over half (95 of 168, 56.5%) reported official approval or certification of the test. Information on accuracy of the test marketed was reported by 87 of 168 (51.7%) websites, with 15 of 168 (8.9%) providing a scientific reference. Instructions for use of the product were found in 97 of 168 (57.9%). However, the course of action to be taken after obtaining the test result was stated in only 63 of 168 (37.5%) for a positive result and 43 of 168 (25.5%) for a negative result. Conclusions The quality of information posted on commercial websites marketing home tests online is unsatisfactory and potentially misleading for consumers. PMID:18263912

  17. Decision making about healthcare-related tests and diagnostic test strategies. Paper 2: a review of methodological and practical challenges.

    Science.gov (United States)

    Mustafa, Reem A; Wiercioch, Wojtek; Cheung, Adrienne; Prediger, Barbara; Brozek, Jan; Bossuyt, Patrick; Garg, Amit X; Lelgemann, Monika; Büehler, Diedrich; Schünemann, Holger J

    2017-12-01

    In this first of a series of five articles, we provide an overview of how and why healthcare-related tests and diagnostic strategies are currently applied. We also describe how our findings can be integrated with existing frameworks for making decisions that guide the use of healthcare-related tests and diagnostic strategies. We searched MEDLINE, references of identified articles, chapters in relevant textbooks, and identified articles citing classic literature on this topic. We provide updated frameworks for the potential roles and applications of tests with suggested definitions and practical examples. We also discuss study designs that are commonly used to assess tests' performance and the effects of tests on people's health. These designs include diagnostic randomized controlled trials and retrospective validation. We describe the utility of these and other currently suggested designs, which questions they can answer and which ones they cannot. In addition, we summarize the challenges unique to decision-making resulting from the use of tests. This overview highlights current challenges in the application of tests in decision-making in healthcare, provides clarifications, and informs the proposed solutions. Copyright © 2017 Elsevier Inc. All rights reserved.

  18. Performance Evaluation of Commercial Dengue Diagnostic Tests for Early Detection of Dengue in Clinical Samples

    Directory of Open Access Journals (Sweden)

    Tuan Nur Akmalina Mat Jusoh

    2017-01-01

    Full Text Available The shattering rise in dengue virus infections globally has created a need for an accurate and validated rapid diagnostic test for this virus. Rapid diagnostic test (RDT and reverse transcription-polymerase chain reaction (RT-PCR diagnostic detection are useful tools for diagnosis of early dengue infection. We prospectively evaluated the diagnostic performance of nonstructural 1 (NS1 RDT and real-time RT-PCR diagnostic kits in 86 patient serum samples. Thirty-six samples were positive for dengue NS1 antigen while the remaining 50 were negative when tested with enzyme-linked immunosorbent assay (ELISA. Commercially available RDTs for NS1 detection, RTK ProDetect™, and SD Bioline showed high sensitivity of 94% and 89%, respectively, compared with ELISA. GenoAmp® Trioplex Real-Time RT-PCR and RealStar® Dengue RT-PCR tests presented a comparable kappa agreement with 0.722. The result obtained from GenoAmp® Real-Time RT-PCR Dengue test showed that 14 samples harbored dengue virus type 1 (DENV-1, 8 samples harbored DENV-2, 2 samples harbored DENV-3, and 1 sample harbored DENV-4. 1 sample had a double infection with DENV-1 and DENV-2. The NS1 RDTs and real-time RT-PCR tests were found to be a useful diagnostic for early and rapid diagnosis of acute dengue and an excellent surveillance tool in our battle against dengue.

  19. Diagnostic and laboratory test ordering in Northern Portuguese Primary Health Care: a cross-sectional study

    Science.gov (United States)

    Sá, Luísa; Teixeira, Andreia Sofia Costa; Tavares, Fernando; Costa-Santos, Cristina; Couto, Luciana; Costa-Pereira, Altamiro; Hespanhol, Alberto Pinto; Santos, Paulo

    2017-01-01

    Objectives To characterise the test ordering pattern in Northern Portugal and to investigate the influence of context-related factors, analysing the test ordered at the level of geographical groups of family physicians and at the level of different healthcare organisations. Design Cross-sectional study. Setting Northern Primary Health Care, Portugal. Participants Records about diagnostic and laboratory tests ordered from 2035 family physicians working at the Northern Regional Health Administration, who served approximately 3.5 million Portuguese patients, in 2014. Outcomes To determine the 20 most ordered diagnostic and laboratory tests in the Northern Regional Health Administration; to identify the presence and extent of variations in the 20 most ordered diagnostic and laboratory tests between the Groups of Primary Care Centres and between health units; and to study factors that may explain these variations. Results The 20 most ordered diagnostic and laboratory tests almost entirely comprise laboratory tests and account for 70.9% of the total tests requested. We can trace a major pattern of test ordering for haemogram, glucose, lipid profile, creatinine and urinalysis. There was a significant difference (P<0.001) in test orders for all tests between Groups of Primary Care Centres and for all tests, except glycated haemoglobin (P=0.06), between health units. Generally, the Personalised Healthcare Units ordered more than Family Health Units. Conclusions The results from this study show that the most commonly ordered tests in Portugal are laboratory tests, that there is a tendency for overtesting and that there is a large variability in diagnostic and laboratory test ordering in different geographical and organisational Portuguese primary care practices, suggesting that there may be considerable potential for the rationalisation of test ordering. The existence of Family Health Units seems to be a strong determinant in decreasing test ordering by Portuguese family

  20. The impact of communication barriers on diagnostic confidence and ancillary testing in the emergency department.

    Science.gov (United States)

    Garra, Gregory; Albino, Hiram; Chapman, Heather; Singer, Adam J; Thode, Henry C

    2010-06-01

    Communication barriers (CBs) compromise the diagnostic power of the medical interview and may result in increased reliance on diagnostic tests or incorrect test ordering. The prevalence and degree to which these barriers affect diagnosis, testing, and treatment are unknown. To quantify and characterize CBs encountered in the Emergency Department (ED), and assess the effect of CBs on initial diagnosis and perceived reliance on ancillary testing. This was a prospective survey completed by emergency physicians after initial adult patient encounters. CB severity, diagnostic confidence, and reliance on ancillary testing were quantified on a 100-mm Visual Analog Scale (VAS) from least (0) to most (100). Data were collected on 417 ED patient encounters. CBs were reported in 46%; with a mean severity of 50 mm on a 100-mm VAS with endpoints of "perfect communication and "no communication." Language was the most commonly reported form of CB (28%). More than one CB was identified in 6%. The 100-mm VAS rating of diagnostic confidence was lower in patients with perceived CBs (64 mm) vs. those without CBs (80 mm), p Communication barriers in our ED setting were common, and resulted in lower diagnostic confidence and increased perception that ancillary tests are needed to narrow the diagnosis. Copyright 2010 Elsevier Inc. All rights reserved.

  1. Mirror fusion test facility plasma diagnostics system

    International Nuclear Information System (INIS)

    Thomas, S.R. Jr.; Coffield, F.E.; Davis, G.E.; Felker, B.

    1979-01-01

    During the past 25 years, experiments with several magnetic mirror machines were performed as part of the Magnetic Fusion Energy (MFE) Program at LLL. The latest MFE experiment, the Mirror Fusion Test Facility (MFTF), builds on the advances of earlier machines in initiating, stabilizing, heating, and sustaining plasmas formed with deuterium. The goals of this machine are to increase ion and electron temperatures and show a corresponding increase in containment time, to test theoretical scaling laws of plasma instabilities with increased physical dimensions, and to sustain high-beta plasmas for times that are long compared to the energy containment time. This paper describes the diagnostic system being developed to characterize these plasma parameters

  2. Development of a molecular diagnostic test for Retinitis Pigmentosa in the Japanese population.

    Science.gov (United States)

    Maeda, Akiko; Yoshida, Akiko; Kawai, Kanako; Arai, Yuki; Akiba, Ryutaro; Inaba, Akira; Takagi, Seiji; Fujiki, Ryoji; Hirami, Yasuhiko; Kurimoto, Yasuo; Ohara, Osamu; Takahashi, Masayo

    2018-05-21

    Retinitis Pigmentosa (RP) is the most common form of inherited retinal dystrophy caused by different genetic variants. More than 60 causative genes have been identified to date. The establishment of cost-effective molecular diagnostic tests with high sensitivity and specificity can be beneficial for patients and clinicians. Here, we developed a clinical diagnostic test for RP in the Japanese population. Evaluation of diagnostic technology, Prospective, Clinical and experimental study. A panel of 39 genes reported to cause RP in Japanese patients was established. Next generation sequence (NGS) technology was applied for the analyses of 94 probands with RP and RP-related diseases. After interpretation of detected genetic variants, molecular diagnosis based on a study of the genetic variants and a clinical phenotype was made by a multidisciplinary team including clinicians, researchers and genetic counselors. NGS analyses found 14,343 variants from 94 probands. Among them, 189 variants in 83 probands (88.3% of all cases) were selected as pathogenic variants and 64 probands (68.1%) have variants which can cause diseases. After the deliberation of these 64 cases, molecular diagnosis was made in 43 probands (45.7%). The final molecular diagnostic rate with the current system combining supplemental Sanger sequencing was 47.9% (45 of 94 cases). The RP panel provides the significant advantage of detecting genetic variants with a high molecular diagnostic rate. This type of race-specific high-throughput genotyping allows us to conduct a cost-effective and clinically useful genetic diagnostic test.

  3. Inventions leading to the development of the diagnostic test kit industry--from the modern pregnancy test to the sandwich assays.

    Science.gov (United States)

    Wide, Leif

    2005-01-01

    The universities are encouraged by the government nowadays to stimulate innovations and also to provide the proper machinery for assisting the protection and commercialisation of innovations. A better understanding of the innovation process may help to create an atmosphere suitable for inventions at the university. Examples can be taken from successful innovations previously made at the university. During the 1960's I made a series of inventions, which ultimately led to the development of the diagnostic test kit industry. The first, which I made as an undergraduate, was a simple and reliable test kit for diagnosis of pregnancy. This was followed by the solid phase radioimmunoassay and a solid phase assay for vitamin B12; next, the dual specific non-competitive sandwich assay and the in-vitro test for diagnosis of allergy, called RAST (Radioallergosorbent test). Organon in Holland with the pregnancy test kit, and Pharmacia in Sweden with test kits for radioimmunoassay, became pioneers among the diagnostic test kit industries. Pharmacia Diagnostics later became one of the leading diagnostic test kit companies in the world and has continued to be so in the field of allergy diagnosis. Each one of these inventions started with a few unique observations leading to a technical development. The pregnancy test as well as the allergy test emerged from the development of assay methods with unique qualities with the subsequent search for appropriate applications. The foreseeing of a commercial value on a future market was a very important step. This was followed by the search for a suitable industry interested to exploit the invention with its new business opportunity i.e. apply for a patent, produce and market the products, which in my case consisted of the necessary reagents and equipments for particular diagnostic tests. Finally, an agreement had to be settled between the entrepreneur and the inventors. This report describes these inventions and particularly discusses some

  4. Pre-examination factors affecting molecular diagnostic test results and interpretation: A case-based approach.

    Science.gov (United States)

    Payne, Deborah A; Baluchova, Katarina; Peoc'h, Katell H; van Schaik, Ron H N; Chan, K C Allen; Maekawa, Masato; Mamotte, Cyril; Russomando, Graciela; Rousseau, François; Ahmad-Nejad, Parviz

    2017-04-01

    Multiple organizations produce guidance documents that provide opportunities to harmonize quality practices for diagnostic testing. The International Organization for Standardization ISO 15189 standard addresses requirements for quality in management and technical aspects of the clinical laboratory. One technical aspect addresses the complexities of the pre-examination phase prior to diagnostic testing. The Committee for Molecular Diagnostics of the International Federation for Clinical Chemistry and Laboratory Medicine (also known as, IFCC C-MD) conducted a survey of international molecular laboratories and determined ISO 15189 to be the most referenced guidance document. In this review, the IFCC C-MD provides case-based examples illustrating the value of select pre-examination processes as these processes relate to molecular diagnostic testing. Case-based examples in infectious disease, oncology, inherited disease and pharmacogenomics address the utility of: 1) providing information to patients and users, 2) designing requisition forms, 3) obtaining informed consent and 4) maintaining sample integrity prior to testing. The pre-examination phase requires extensive and consistent communication between the laboratory, the healthcare provider and the end user. The clinical vignettes presented in this paper illustrate the value of applying select ISO 15189 recommendations for general laboratory to the more specialized area of Molecular Diagnostics. Copyright © 2016 Elsevier B.V. All rights reserved.

  5. Achieving robust interchangeability of test assets in ATE systems

    CERN Document Server

    Oblad, R P

    1999-01-01

    This paper identities the key issues that have made if so difficult to achieve asset interchangeability. Several of the historical attempts to solve the problem of asset interchangeability are described, along with an analysis of the reasons that they did not achieve the expected results. Specific topics that are covered are SCPI, VXIplug&play, IVI, ATLAS, and Measurement Subsystems. Principles associated with the ownership of interfaces will be outlined. Finally, a set of rules and principles will be discussed that must be applied to achieve robust asset interchangeability. Robust is defined as interchangeability that can be "guaranteed" without testing all TPSs against the modified test system. (9 refs).

  6. Appraising and applying evidence about a diagnostic test during a performance-based assessment

    Directory of Open Access Journals (Sweden)

    Franklin Ellen

    2004-10-01

    Full Text Available Abstract Background The practice of Evidence-based Medicine requires that clinicians assess the validity of published research and then apply the results to patient care. We wanted to assess whether our soon-to-graduate medical students could appraise and apply research about a diagnostic test within a clinical context and to compare our students with peers trained at other institutions. Methods 4th year medical students who previously had demonstrated competency at probability revision and just starting first-year Internal Medicine residents were used for this research. Following an encounter with a simulated patient, subjects critically appraised a paper about an applicable diagnostic test and revised the patient's pretest probability given the test result. Results The medical students and residents demonstrated similar skills at critical appraisal, correctly answering 4.7 and 4.9, respectively, of 6 questions (p = 0.67. Only one out of 28 (3% medical students and none of the 15 residents were able to correctly complete the probability revision task (p = 1.00. Conclusions This study found that most students completing medical school are able to appraise an article about a diagnostic test but few are able to apply the information from the article to a patient. These findings raise questions about the clinical usefulness of the EBM skills possessed by graduating medical students within the area of diagnostic testing.

  7. Sequential Test Selection by Quantifying of the Reduction in Diagnostic Uncertainty for the Diagnosis of Proximal Caries

    Directory of Open Access Journals (Sweden)

    Umut Arslan

    2013-06-01

    Full Text Available Background: In order to determine the presence or absence of a certain disease, multiple diagnostic tests may be necessary. Performance of these tests can be sequentially evaluated. Aims: The aim of the study is to determine the contribution of the test in each step, in reducing diagnostic uncertainty when multiple tests are sequentially used for the diagnosis. Study Design: Diagnostic accuracy study Methods: Radiographs of seventy-three patients of the Department of Dento-Maxillofacial Radiology of Hacettepe University Faculty of Dentistry were assessed. Panoramic (PAN, full mouth intraoral (FM, and bitewing (BW radiographs were used for the diagnosis of proximal caries in the maxillary and mandibular molar regions. Diagnostic performance of radiography was sequentially evaluated by using the reduction in diagnostic uncertainty. Results: FM provided maximum diagnostic information for ruling in potential in the maxillary and mandibular molar regions in the first step. FM provided more diagnostic information than BW radiographs for ruling in the mandibular region in the second step. In the mandibular region, BW radiographs provided more diagnostic information than FM for ruling out in the first step. Conclusion: The presented method in this study provides the clinicians with a solution for the decision of the sequential selection of diagnostic tests for the correct diagnosis of the presence or absence of a certain disease.

  8. Learned Helplessness, Test Anxiety, and Academic Achievement: A Longitudinal Analysis.

    Science.gov (United States)

    Fincham, Frank D.; And Others

    1989-01-01

    Examines the stability of individual differences in test anxiety and learned helplessness of 82 children in third grade and later in fifth grade. Results indicate that teacher reports of helplessness had the strongest and most consistent relation to concurrent achievement and to achievement test scores two years later. (RJC)

  9. Privacy and equality in diagnostic genetic testing.

    Science.gov (United States)

    Nyrhinen, Tarja; Hietala, Marja; Puukka, Pauli; Leino-Kilpi, Helena

    2007-05-01

    This study aimed to determine the extent to which the principles of privacy and equality were observed during diagnostic genetic testing according to views held by patients or child patients' parents (n = 106) and by staff (n = 162) from three Finnish university hospitals. The data were collected through a structured questionnaire and analysed using the SAS 8.1 statistical software. In general, the two principles were observed relatively satisfactorily in clinical practice. According to patients/parents, equality in the post-analytic phase and, according to staff, privacy in the pre-analytic phase, involved the greatest ethical problems. The two groups differed in their views concerning pre-analytic privacy. Although there were no major problems regarding the two principles, the differences between the testing phases require further clarification. To enhance privacy protection and equality, professionals need to be given more genetics/ethics training, and patients individual counselling by genetics units staff, giving more consideration to patients' world-view, the purpose of the test and the test result.

  10. Computer-Adaptive Testing: Implications for Students' Achievement, Motivation, Engagement, and Subjective Test Experience

    Science.gov (United States)

    Martin, Andrew J.; Lazendic, Goran

    2018-01-01

    The present study investigated the implications of computer-adaptive testing (operationalized by way of multistage adaptive testing; MAT) and "conventional" fixed order computer testing for various test-relevant outcomes in numeracy, including achievement, test-relevant motivation and engagement, and subjective test experience. It did so…

  11. Diagnostic accuracy of scapular physical examination tests for shoulder disorders: a systematic review.

    Science.gov (United States)

    Wright, Alexis A; Wassinger, Craig A; Frank, Mason; Michener, Lori A; Hegedus, Eric J

    2013-09-01

    To systematically review and critique the evidence regarding the diagnostic accuracy of physical examination tests for the scapula in patients with shoulder disorders. A systematic, computerised literature search of PubMED, EMBASE, CINAHL and the Cochrane Library databases (from database inception through January 2012) using keywords related to diagnostic accuracy of physical examination tests of the scapula. The Quality Assessment of Diagnostic Accuracy Studies tool was used to critique the quality of each paper. Eight articles met the inclusion criteria; three were considered to be of high quality. Of the three high-quality studies, two were in reference to a 'diagnosis' of shoulder pain. Only one high-quality article referenced specific shoulder pathology of acromioclavicular dislocation with reported sensitivity of 71% and 41% for the scapular dyskinesis and SICK scapula test, respectively. Overall, no physical examination test of the scapula was found to be useful in differentially diagnosing pathologies of the shoulder.

  12. The evaluation and impact of diagnostic tests

    International Nuclear Information System (INIS)

    Royal, H.D.; McNeil, B.J.

    1989-01-01

    The authors describe the usefulness of the techniques that are applied to study the role of tests and point out their limitations. In many instances, complex tasks must be oversimplified in order to use currently available analytic tools. Certain tools, such as decision analysis, are useful not only because they can provide insight regarding the most favorable diagnostic/therapeutic strategies but also because they can identify areas where present knowledge is inadequate and thereby help put priorities on areas of research

  13. Bayesian analysis of longitudinal Johne's disease diagnostic data without a gold standard test

    DEFF Research Database (Denmark)

    Wang, C.; Turnbull, B.W.; Nielsen, Søren Saxmose

    2011-01-01

    the posterior estimates of the model parameters that provide the basis for inference concerning the accuracy of the diagnostic procedure. Based on the Bayesian approach, the posterior probability distribution of the change-point onset time can be obtained and used as a criterion for infection diagnosis......-point process with a Weibull survival hazard function was used to model the progression of the hidden disease status. The model adjusted for the fixed effects of covariate variables and random effects of subject on the diagnostic testing procedure. Markov chain Monte Carlo methods were used to compute....... An application is presented to an analysis of ELISA and fecal culture test outcomes in the diagnostic testing of paratuberculosis (Johne's disease) for a Danish longitudinal study from January 2000 to March 2003. The posterior probability criterion based on the Bayesian model with 4 repeated observations has...

  14. Evaluation of microscopy and rapid diagnostic tests in screening ...

    African Journals Online (AJOL)

    Malaria is a life-threatening disease caused by the protozoa of the genus Plasmodium. Infection of individual is through the bites of infected female Anopheles mosquitoes. This study evaluated the performance of microscopy and rapid diagnostic tests (RDTs) in diagnosing malaria. A total of 400 clinically suspected malaria ...

  15. Achievement Goals and Achievement Emotions: Testing a Model of Their Joint Relations with Academic Performance

    Science.gov (United States)

    Pekrun, Reinhard; Elliot, Andrew J.; Maier, Markus A.

    2009-01-01

    The authors propose a theoretical model linking achievement goals and achievement emotions to academic performance. This model was tested in a prospective study with undergraduates (N = 213), using exam-specific assessments of both goals and emotions as predictors of exam performance in an introductory-level psychology course. The findings were…

  16. Prospective evaluation of three rapid diagnostic tests for diagnosis of human leptospirosis.

    Directory of Open Access Journals (Sweden)

    Marga G A Goris

    Full Text Available BACKGROUND: Diagnosis of leptospirosis by the microscopic agglutination test (MAT or by culture is confined to specialized laboratories. Although ELISA techniques are more common, they still require laboratory facilities. Rapid Diagnostic Tests (RDTs can be used for easy point-of-care diagnosis. This study aims to evaluate the diagnostic performance of the RDTs LeptoTek Dri Dot, LeptoTek Lateral Flow, and Leptocheck-WB, prospectively. METHODOLOGY: During 2001 to 2012, one or two of the RDTs at the same time have been applied prior to routine diagnostics (MAT, ELISA and culture on serum specimens from participants sent in for leptospirosis diagnosis. The case definition was based on MAT, ELISA and culture results. Participants not fulfilling the case definition were considered not to have leptospirosis. The diagnostic accuracy was determined based on the 1(st submitted sample and paired samples, either in an overall analysis or stratified according to days post onset of illness. RESULTS: The overall sensitivity and specificity for the LeptoTek Dri Dot was 75% respectively 96%, for the LeptoTek Lateral Flow 78% respectively 95%, and for the Leptocheck-WB 78% respectively 98%. Based on the 1(st submitted sample the sensitivity was low (51% for LeptoTek Dri Dot, 69% for LeptoTek Lateral Flow, and 55% for Leptocheck-WB, but substantially increased when the results of paired samples were combined, although accompanied by a lower specificity (82% respectively 91% for LeptoTek Dri Dot, 86% respectively 84% for LeptoTek Lateral Flow, and 80% respectively 93% for Leptocheck-WB. CONCLUSIONS: All three tests present antibody tests contributing to the diagnosis of leptospirosis, thus supporting clinical suspicion and contributing to awareness. Since the overall sensitivity of the tested RDTs did not exceed 80%, one should be cautious to rely only on an RDT result, and confirmation by reference tests is strongly recommended.

  17. Reference materials for molecular diagnostics: Current achievements and future strategies.

    Science.gov (United States)

    Jing, Rongrong; Wang, Huimin; Ju, Shaoqing; Cui, Ming

    2018-06-01

    Molecular diagnoses have become more widespread in many areas of laboratory medicine where qualitative or quantitative approaches are used to detect nucleic acids. The increasing number of assay methods and the targets for molecular diagnostics contribute to variability in the test results among clinical laboratories. Thus, reference materials (RMs) are required to enhance the comparability of results. This review focuses on the definition of RMs as well as the production and characteristics of higher order RMs from different organizations and their future strategies. We describe the recent progress in RMs, including the definition of RMs by the Joint Committee for Guides in Metrology, as well as the production and characteristics of higher order RMs by international official bodies. There is an urgent need for RMs in nucleic acid testing, especially higher order RMs. To advance the harmonization and standardization of clinical nucleic acid detection, cooperation between the above organizations is proposed and different approaches to higher order RMs development are also needed. Copyright © 2018 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  18. Lacrimination in Sjogren′s syndrome. Is Schirmer′s test really a useful diagnostic tool?

    Directory of Open Access Journals (Sweden)

    Bhadoria D

    1988-01-01

    Full Text Available In the past, Schinier′s test was used as a diagnostic tool in Sjogren′s Syndrome. In this study, a comparison of 100 normal patients with 2l patients with Sjogren′s Syndrome has been made to study its reliability. It has been concluded that Schimer′s test is of a poor diagnostic value in Sjogren′s Syndrome.

  19. Diagnostic Accuracy of Tests for Polyuria in Lithium-Treated Patients.

    Science.gov (United States)

    Kinahan, James Conor; NiChorcorain, Aoife; Cunningham, Sean; Freyne, Aideen; Cooney, Colm; Barry, Siobhan; Kelly, Brendan D

    2015-08-01

    In lithium-treated patients, polyuria increases the risk of dehydration and lithium toxicity. If detected early, it is reversible. Despite its prevalence and associated morbidity in clinical practice, it remains underrecognized and therefore undertreated. The 24-hour urine collection is limited by its convenience and practicality. This study explores the diagnostic accuracy of alternative tests such as questionnaires on subjective polyuria, polydipsia, nocturia (dichotomous and ordinal responses), early morning urine sample osmolality (EMUO), and fluid intake record (FIR). This is a cross-sectional study of 179 lithium-treated patients attending a general adult and an old age psychiatry service. Participants completed the tests after completing an accurate 24-hour urine collection. The diagnostic accuracy of the individual tests was explored using the appropriate statistical techniques. Seventy-nine participants completed all of the tests. Polydipsia severity, EMUO, and FIR significantly differentiated the participants with polyuria (area under the receiver operating characteristic curve of 0.646, 0.760, and 0.846, respectively). Of the tests investigated, the FIR made the largest significant change in the probability that a patient experiences polyuria (3500 mL/24 hours; interval likelihood ratio, 14). Symptomatic questioning, EMUO, and an FIR could be used in clinical practice to inform the prescriber of the probability that a lithium-treated patient is experiencing polyuria.

  20. Concordance in diagnostic testing for respiratory pathogens of Bighorn Sheep

    Science.gov (United States)

    Reliable diagnostic tests are essential for disease investigation and management. This is particularly true for diseases of free-ranging wildlife where sampling is logistically difficult precluding retesting. Clinical assays for wildlife diseases frequently vary among laboratories because of lack ...

  1. Diagnostic Algorithm for Glycogenoses and Myoadenylate Deaminase Deficiency Based on Exercise Testing Parameters: A Prospective Study.

    Directory of Open Access Journals (Sweden)

    Fabrice Rannou

    Full Text Available Our aim was to evaluate the accuracy of aerobic exercise testing to diagnose metabolic myopathies.From December 2008 to September 2012, all the consecutive patients that underwent both metabolic exercise testing and a muscle biopsy were prospectively enrolled. Subjects performed an incremental and maximal exercise testing on a cycle ergometer. Lactate, pyruvate, and ammonia concentrations were determined from venous blood samples drawn at rest, during exercise (50% predicted maximal power, peak exercise, and recovery (2, 5, 10, and 15 min. Biopsies from vastus lateralis or deltoid muscles were analysed using standard techniques (reference test. Myoadenylate deaminase (MAD activity was determined using p-nitro blue tetrazolium staining in muscle cryostat sections. Glycogen storage was assessed using periodic acid-Schiff staining. The diagnostic accuracy of plasma metabolite levels to identify absent and decreased MAD activity was assessed using Receiver Operating Characteristic (ROC curve analysis.The study involved 51 patients. Omitting patients with glycogenoses (n = 3, MAD staining was absent in 5, decreased in 6, and normal in 37 subjects. Lactate/pyruvate at the 10th minute of recovery provided the greatest area under the ROC curves (AUC, 0.893 ± 0.067 to differentiate Abnormal from Normal MAD activity. The lactate/rest ratio at the 10th minute of recovery from exercise displayed the best AUC (1.0 for discriminating between Decreased and Absent MAD activities. The resulting decision tree achieved a diagnostic accuracy of 86.3%.The present algorithm provides a non-invasive test to accurately predict absent and decreased MAD activity, facilitating the selection of patients for muscle biopsy and target appropriate histochemical analysis.

  2. Diagnostic Accuracy of the Slump Test for Identifying Neuropathic Pain in the Lower Limb.

    Science.gov (United States)

    Urban, Lawrence M; MacNeil, Brian J

    2015-08-01

    Diagnostic accuracy study with nonconsecutive enrollment. To assess the diagnostic accuracy of the slump test for neuropathic pain (NeP) in those with low to moderate levels of chronic low back pain (LBP), and to determine whether accuracy of the slump test improves by adding anatomical or qualitative pain descriptors. Neuropathic pain has been linked with poor outcomes, likely due to inadequate diagnosis, which precludes treatment specific for NeP. Current diagnostic approaches are time consuming or lack accuracy. A convenience sample of 21 individuals with LBP, with or without radiating leg pain, was recruited. A standardized neurosensory examination was used to determine the reference diagnosis for NeP. Afterward, the slump test was administered to all participants. Reports of pain location and quality produced during the slump test were recorded. The neurosensory examination designated 11 of the 21 participants with LBP/sciatica as having NeP. The slump test displayed high sensitivity (0.91), moderate specificity (0.70), a positive likelihood ratio of 3.03, and a negative likelihood ratio of 0.13. Adding the criterion of pain below the knee significantly increased specificity to 1.00 (positive likelihood ratio = 11.9). Pain-quality descriptors did not improve diagnostic accuracy. The slump test was highly sensitive in identifying NeP within the study sample. Adding a pain-location criterion improved specificity. Combining the diagnostic outcomes was very effective in identifying all those without NeP and half of those with NeP. Limitations arising from the small and narrow spectrum of participants with LBP/sciatica sampled within the study prevent application of the findings to a wider population. Diagnosis, level 4-.

  3. Preferred Reporting Items for a Systematic Review and Meta-analysis of Diagnostic Test Accuracy Studies: The PRISMA-DTA Statement.

    Science.gov (United States)

    McInnes, Matthew D F; Moher, David; Thombs, Brett D; McGrath, Trevor A; Bossuyt, Patrick M; Clifford, Tammy; Cohen, Jérémie F; Deeks, Jonathan J; Gatsonis, Constantine; Hooft, Lotty; Hunt, Harriet A; Hyde, Christopher J; Korevaar, Daniël A; Leeflang, Mariska M G; Macaskill, Petra; Reitsma, Johannes B; Rodin, Rachel; Rutjes, Anne W S; Salameh, Jean-Paul; Stevens, Adrienne; Takwoingi, Yemisi; Tonelli, Marcello; Weeks, Laura; Whiting, Penny; Willis, Brian H

    2018-01-23

    Systematic reviews of diagnostic test accuracy synthesize data from primary diagnostic studies that have evaluated the accuracy of 1 or more index tests against a reference standard, provide estimates of test performance, allow comparisons of the accuracy of different tests, and facilitate the identification of sources of variability in test accuracy. To develop the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) diagnostic test accuracy guideline as a stand-alone extension of the PRISMA statement. Modifications to the PRISMA statement reflect the specific requirements for reporting of systematic reviews and meta-analyses of diagnostic test accuracy studies and the abstracts for these reviews. Established standards from the Enhancing the Quality and Transparency of Health Research (EQUATOR) Network were followed for the development of the guideline. The original PRISMA statement was used as a framework on which to modify and add items. A group of 24 multidisciplinary experts used a systematic review of articles on existing reporting guidelines and methods, a 3-round Delphi process, a consensus meeting, pilot testing, and iterative refinement to develop the PRISMA diagnostic test accuracy guideline. The final version of the PRISMA diagnostic test accuracy guideline checklist was approved by the group. The systematic review (produced 64 items) and the Delphi process (provided feedback on 7 proposed items; 1 item was later split into 2 items) identified 71 potentially relevant items for consideration. The Delphi process reduced these to 60 items that were discussed at the consensus meeting. Following the meeting, pilot testing and iterative feedback were used to generate the 27-item PRISMA diagnostic test accuracy checklist. To reflect specific or optimal contemporary systematic review methods for diagnostic test accuracy, 8 of the 27 original PRISMA items were left unchanged, 17 were modified, 2 were added, and 2 were omitted. The 27-item

  4. Plasma diagnostic development and UHV testing for the ALPHA collaboration at Marquette University

    Science.gov (United States)

    Tharp, T. D.; Alpha Collaboration

    2017-10-01

    At Marquette, we are developing the next generation of nonneutral plasma diagnostics for the ALPHA experiment at CERN. ALPHA is building a new vertical experiment to test the gravitational interaction of antihydrogen with Earth. This expansion requires significant changes to the design of our plasma diagnostic suites: the next generation of tools must be able to measure plasmas from two directions, and must be capable of operating in a horizontal position. The diagnostic suite includes measurements of plasma density, shape, and temperature. The hardware used includes a MicroChannel Plate (MCP), a Faraday Cup, and an electron gun. In addition, we are building a vacuum chamber to test the viability of 3-d printed components for UHV compatibility, with target pressures of 10-10 mbar.

  5. Cost-effectiveness of using a molecular diagnostic test to improve preoperative diagnosis of thyroid cancer.

    Science.gov (United States)

    Najafzadeh, Mehdi; Marra, Carlo A; Lynd, Larry D; Wiseman, Sam M

    2012-12-01

    Fine-needle aspiration biopsy (FNAB) is a safe and inexpensive diagnostic procedure for evaluating thyroid nodules.Up to 25% of the results from an FNAB, however, may not be diagnostic or may be indeterminate, leading to a subsequent diagnostic thyroid surgery. A new molecularly based diagnostic test could potentially reduce indeterminate cytological results and, with high accuracy, provide a definitive diagnosis for cancer in thyroid nodules. The aim of the study was to estimate the cost-effectiveness of utilizing a molecular diagnostic (DX) test as an adjunct to FNAB, compared with NoDX, to improve the preoperative diagnosis of thyroid nodules. We constructed a patient-level simulation model to estimate the clinical and economic outcomes of using a DX test compared with current practice (NoDX) for the diagnosis of thyroid nodules. By using a cost-effectiveness framework, we measured incremental clinical benefits in terms of quality-adjusted life-years and incremental costs over a 10-year time horizon. Assuming 95% sensitivity and specificity of the Dx test when used as an adjunct to FNAB, the utilization of the DX test resulted in a gain of 0.046 quality-adjusted life-years (95% confidence interval 0.019-0.078) and a saving of $1087 (95% confidence interval $691-$1533) in direct costs per patient. If the cost of the Dx test is less than $1087 per test, we expect to save quality-adjusted life-years and reduce costs when it is utilized. Sensitivity of the DX test, compared with specificity, had a larger influence on the overall outcomes. Copyright © 2012 International Society for Pharmacoeconomics and Outcomes Research (ISPOR). Published by Elsevier Inc. All rights reserved.

  6. Classification of chronic orofacial pain using an intravenous diagnostic test

    NARCIS (Netherlands)

    Tjakkes, G. -H. E.; De Bont, L. G. M.; van Wijhe, M.; Stegenga, B.

    The aim of this study was to evaluate the ability of a preliminary intravenous diagnostic test to classify chronic orofacial pain patients into different subgroups. Patients with chronic orofacial pain conditions that could not be unambiguously diagnosed. A retrospective evaluation of series of

  7. Portuguese Family Physicians' Awareness of Diagnostic and Laboratory Test Costs: A Cross-Sectional Study.

    Directory of Open Access Journals (Sweden)

    Luísa Sá

    Full Text Available Physicians' ability to make cost-effective decisions has been shown to be affected by their knowledge of health care costs. This study assessed whether Portuguese family physicians are aware of the costs of the most frequently prescribed diagnostic and laboratory tests.A cross-sectional study was conducted in a representative sample of Portuguese family physicians, using computer-assisted telephone interviews for data collection. A Likert scale was used to assess physician's level of agreement with four statements about health care costs. Family physicians were also asked to estimate the costs of diagnostic and laboratory tests. Each physician's cost estimate was compared with the true cost and the absolute error was calculated.One-quarter (24%; 95% confidence interval: 23%-25% of all cost estimates were accurate to within 25% of the true cost, with 55% (95% IC: 53-56 overestimating and 21% (95% IC: 20-22 underestimating the true actual cost. The majority (76% of family physicians thought they did not have or were uncertain as to whether they had adequate knowledge of diagnostic and laboratory test costs, and only 7% reported receiving adequate education. The majority of the family physicians (82% said that they had adequate access to information about the diagnostic and laboratory test costs. Thirty-three percent thought that costs did not influence their decision to order tests, while 27% were uncertain.Portuguese family physicians have limited awareness of diagnostic and laboratory test costs, and our results demonstrate a need for improved education in this area. Further research should focus on identifying whether interventions in cost knowledge actually change ordering behavior, in identifying optimal methods to disseminate cost information, and on improving the cost-effectiveness of care.

  8. Portuguese Family Physicians’ Awareness of Diagnostic and Laboratory Test Costs: A Cross-Sectional Study

    Science.gov (United States)

    Sá, Luísa; Costa-Santos, Cristina; Teixeira, Andreia; Couto, Luciana; Costa-Pereira, Altamiro; Hespanhol, Alberto; Santos, Paulo; Martins, Carlos

    2015-01-01

    Background Physicians’ ability to make cost-effective decisions has been shown to be affected by their knowledge of health care costs. This study assessed whether Portuguese family physicians are aware of the costs of the most frequently prescribed diagnostic and laboratory tests. Methods A cross-sectional study was conducted in a representative sample of Portuguese family physicians, using computer-assisted telephone interviews for data collection. A Likert scale was used to assess physician’s level of agreement with four statements about health care costs. Family physicians were also asked to estimate the costs of diagnostic and laboratory tests. Each physician’s cost estimate was compared with the true cost and the absolute error was calculated. Results One-quarter (24%; 95% confidence interval: 23%–25%) of all cost estimates were accurate to within 25% of the true cost, with 55% (95% IC: 53–56) overestimating and 21% (95% IC: 20–22) underestimating the true actual cost. The majority (76%) of family physicians thought they did not have or were uncertain as to whether they had adequate knowledge of diagnostic and laboratory test costs, and only 7% reported receiving adequate education. The majority of the family physicians (82%) said that they had adequate access to information about the diagnostic and laboratory test costs. Thirty-three percent thought that costs did not influence their decision to order tests, while 27% were uncertain. Conclusions Portuguese family physicians have limited awareness of diagnostic and laboratory test costs, and our results demonstrate a need for improved education in this area. Further research should focus on identifying whether interventions in cost knowledge actually change ordering behavior, in identifying optimal methods to disseminate cost information, and on improving the cost-effectiveness of care. PMID:26356625

  9. Dual Processing Model for Medical Decision-Making: An Extension to Diagnostic Testing.

    Science.gov (United States)

    Tsalatsanis, Athanasios; Hozo, Iztok; Kumar, Ambuj; Djulbegovic, Benjamin

    2015-01-01

    Dual Processing Theories (DPT) assume that human cognition is governed by two distinct types of processes typically referred to as type 1 (intuitive) and type 2 (deliberative). Based on DPT we have derived a Dual Processing Model (DPM) to describe and explain therapeutic medical decision-making. The DPM model indicates that doctors decide to treat when treatment benefits outweigh its harms, which occurs when the probability of the disease is greater than the so called "threshold probability" at which treatment benefits are equal to treatment harms. Here we extend our work to include a wider class of decision problems that involve diagnostic testing. We illustrate applicability of the proposed model in a typical clinical scenario considering the management of a patient with prostate cancer. To that end, we calculate and compare two types of decision-thresholds: one that adheres to expected utility theory (EUT) and the second according to DPM. Our results showed that the decisions to administer a diagnostic test could be better explained using the DPM threshold. This is because such decisions depend on objective evidence of test/treatment benefits and harms as well as type 1 cognition of benefits and harms, which are not considered under EUT. Given that type 1 processes are unique to each decision-maker, this means that the DPM threshold will vary among different individuals. We also showed that when type 1 processes exclusively dominate decisions, ordering a diagnostic test does not affect a decision; the decision is based on the assessment of benefits and harms of treatment. These findings could explain variations in the treatment and diagnostic patterns documented in today's clinical practice.

  10. Dual Processing Model for Medical Decision-Making: An Extension to Diagnostic Testing.

    Directory of Open Access Journals (Sweden)

    Athanasios Tsalatsanis

    Full Text Available Dual Processing Theories (DPT assume that human cognition is governed by two distinct types of processes typically referred to as type 1 (intuitive and type 2 (deliberative. Based on DPT we have derived a Dual Processing Model (DPM to describe and explain therapeutic medical decision-making. The DPM model indicates that doctors decide to treat when treatment benefits outweigh its harms, which occurs when the probability of the disease is greater than the so called "threshold probability" at which treatment benefits are equal to treatment harms. Here we extend our work to include a wider class of decision problems that involve diagnostic testing. We illustrate applicability of the proposed model in a typical clinical scenario considering the management of a patient with prostate cancer. To that end, we calculate and compare two types of decision-thresholds: one that adheres to expected utility theory (EUT and the second according to DPM. Our results showed that the decisions to administer a diagnostic test could be better explained using the DPM threshold. This is because such decisions depend on objective evidence of test/treatment benefits and harms as well as type 1 cognition of benefits and harms, which are not considered under EUT. Given that type 1 processes are unique to each decision-maker, this means that the DPM threshold will vary among different individuals. We also showed that when type 1 processes exclusively dominate decisions, ordering a diagnostic test does not affect a decision; the decision is based on the assessment of benefits and harms of treatment. These findings could explain variations in the treatment and diagnostic patterns documented in today's clinical practice.

  11. Development, Evaluation, and Integration of a Quantitative Reverse-Transcription Polymerase Chain Reaction Diagnostic Test for Ebola Virus on a Molecular Diagnostics Platform.

    Science.gov (United States)

    Cnops, Lieselotte; Van den Eede, Peter; Pettitt, James; Heyndrickx, Leo; De Smet, Birgit; Coppens, Sandra; Andries, Ilse; Pattery, Theresa; Van Hove, Luc; Meersseman, Geert; Van Den Herrewegen, Sari; Vergauwe, Nicolas; Thijs, Rein; Jahrling, Peter B; Nauwelaers, David; Ariën, Kevin K

    2016-10-15

     The 2013-2016 Ebola epidemic in West Africa resulted in accelerated development of rapid diagnostic tests for emergency outbreak preparedness. We describe the development and evaluation of the Idylla™ prototype Ebola virus test, a fully automated sample-to-result molecular diagnostic test for rapid detection of Zaire ebolavirus (EBOV) and Sudan ebolavirus (SUDV).  The Idylla™ prototype Ebola virus test can simultaneously detect EBOV and SUDV in 200 µL of whole blood. The sample is directly added to a disposable cartridge containing all reagents for sample preparation, RNA extraction, and amplification by reverse-transcription polymerase chain reaction analysis. The performance was evaluated with a variety of sample types, including synthetic constructs and whole blood samples from healthy volunteers spiked with viral RNA, inactivated virus, and infectious virus.  The 95% limits of detection for EBOV and SUDV were 465 plaque-forming units (PFU)/mL (1010 copies/mL) and 324 PFU/mL (8204 copies/mL), respectively. In silico and in vitro analyses demonstrated 100% correct reactivity for EBOV and SUDV and no cross-reactivity with relevant pathogens. The diagnostic sensitivity was 97.4% (for EBOV) and 91.7% (for SUDV), the specificity was 100%, and the diagnostic accuracy was 95.9%.  The Idylla™ prototype Ebola virus test is a fast, safe, easy-to-use, and near-patient test that meets the performance criteria to detect EBOV in patients with suspected Ebola. © The Author 2016. Published by Oxford University Press for the Infectious Diseases Society of America. All rights reserved. For permissions, e-mail journals.permissions@oup.com.

  12. Online formative tests linked to microlectures improving academic achievement.

    Science.gov (United States)

    Bouwmeester, Rianne A M; de Kleijn, Renske A M; Freriksen, Astrid W M; van Emst, Maarten G; Veeneklaas, Rob J; van Hoeij, Maggy J W; Spinder, Matty; Ritzen, Magda J; Ten Cate, Olle Th J; van Rijen, Harold V M

    2013-12-01

    Online formative tests (OFTs) are powerful tools to direct student learning behavior, especially when enriched with specific feedback. In the present study, we have investigated the effect of OFTs enriched with hyperlinks to microlectures on examination scores. OFTs, available one week preceding each midterm and the final exams, could be used voluntarily. The use of OFTs was related to scores on midterm and final exams using ANOVA, with prior academic achievement as a covariate. On average, 74% of all students used the online formative tests (OFT+) while preparing for the summative midterm exam. OFT+ students obtained significantly higher grades compared to OFT-students, both without and with correction for previous academic achievement. Two out of three final exam scores did not significantly improve. Students using online formative tests linked to microlectures receive higher grades especially in highly aligned summative tests.

  13. In Search of Optimal Cognitive Diagnostic Model(s) for ESL Grammar Test Data

    Science.gov (United States)

    Yi, Yeon-Sook

    2017-01-01

    This study compares five cognitive diagnostic models in search of optimal one(s) for English as a Second Language grammar test data. Using a unified modeling framework that can represent specific models with proper constraints, the article first fit the full model (the log-linear cognitive diagnostic model, LCDM) and investigated which model…

  14. Consensus-based reporting standards for diagnostic test accuracy studies for paratuberculosis in ruminants

    DEFF Research Database (Denmark)

    Gardner, Ian A.; Nielsen, Søren Saxmose; Whittington, Richard

    2011-01-01

    The Standards for Reporting of Diagnostic Accuracy (STARD) statement (www.stard-statement.org) was developed to encourage complete and transparent reporting of key elements of test accuracy studies in human medicine. The statement was motivated by widespread evidence of bias in test accuracy...... studies and the finding that incomplete or absent reporting of items in the STARD checklist was associated with overly optimistic estimates of test performance characteristics. Although STARD principles apply broadly, specific guidelines do not exist to account for unique considerations in livestock...... for Reporting of Animal Diagnostic Accuracy Studies for paratuberculosis), should facilitate improved quality of reporting of the design, conduct and results of paratuberculosis test accuracy studies which were identified as “poor” in a review published in 2008 in Veterinary Microbiology...

  15. Convergent and diagnostic validity of STAVUX, a word and pseudoword spelling test for adults.

    Science.gov (United States)

    Östberg, Per; Backlund, Charlotte; Lindström, Emma

    2016-10-01

    Few comprehensive spelling tests are available in Swedish, and none have been validated in adults with reading and writing disorders. The recently developed STAVUX test includes word and pseudoword spelling subtests with high internal consistency and adult norms stratified by education. This study evaluated the convergent and diagnostic validity of STAVUX in adults with dyslexia. Forty-six adults, 23 with dyslexia and 23 controls, took STAVUX together with a standard word-decoding test and a self-rated measure of spelling skills. STAVUX subtest scores showed moderate to strong correlations with word-decoding scores and predicted self-rated spelling skills. Word and pseudoword subtest scores both predicted dyslexia status. Receiver-operating characteristic (ROC) analysis showed excellent diagnostic discriminability. Sensitivity was 91% and specificity 96%. In conclusion, the results of this study support the convergent and diagnostic validity of STAVUX.

  16. A new condition for assessing the clinical efficiency of a diagnostic test.

    Science.gov (United States)

    Bokhari, Ehsan; Hubert, Lawrence

    2015-09-01

    When prediction using a diagnostic test outperforms simple prediction using base rates, the test is said to be "clinically efficient," a term first introduced into the literature by Meehl and Rosen (1955) in Psychological Bulletin. This article provides three equivalent conditions for determining the clinical efficiency of a diagnostic test: (a) Meehl-Rosen (Meehl & Rosen, 1955); (b) Dawes (Dawes, 1962); and (c) the Bokhari-Hubert condition, introduced here for the first time. Clinical efficiency is then generalized to situations where misclassification costs are considered unequal (for example, false negatives are more costly than false positives). As an illustration, the clinical efficiency of an actuarial device for predicting violent and dangerous behavior is examined that was developed as part of the MacArthur Violence Risk Assessment Study. (c) 2015 APA, all rights reserved.

  17. Quality assurance in diagnostic radiology in Hungary - first experiences in acceptance testing

    International Nuclear Information System (INIS)

    Porubszky, T.; Pellet, S.; Ballay, L.; Talian, L.; Giczi, F.

    2003-01-01

    It is a general experience that optimum imaging with minimum patient doses, moreover, the safe operation and long life of X-ray equipment can be assured by regular measurement of technical parameters and checking of their constancy (routine performance testing) only. These tests are generally known as quality control, while together with the so-called corrective actions and its management it is called (physical-technical) quality assurance (QA). In the European Union, Directive 97/43/EURATOM about radiation protection of patients requires - among others - the good practice of (physical-technical) quality assurance. In Hungary, Decree No. 31/2001. (X.3.) of the Minister of Health harmonizes all of its requirements. Acceptance testing of new diagnostic X-ray equipment is assigned to NPHC-NRIRR. QA has been a daily practice in radiation therapy and nuclear medicine for a long time. A National Patient Dose Assessment Programme has also successfully run since 1989. We had, however, only few preliminaries in QA in diagnostic radiology in the second half of the eighties. Nowadays there are running QA programmes in some hospitals and mammography centres. he testing activity of our institute is independent from manufacturers, it is run within the frame of an accredited testing laboratory, using calibrated measuring instruments and based on valid international standards. So the started way of implementing QA in diagnostic radiology needs a lot of further efforts, adapting experiences of other countries, and also some financial help to reach an acceptable level in the EU. (authors)

  18. 2012 HIV Diagnostics Conference: the molecular diagnostics perspective.

    Science.gov (United States)

    Branson, Bernard M; Pandori, Mark

    2013-04-01

    2012 HIV Diagnostic Conference Atlanta, GA, USA, 12-14 December 2012. This report highlights the presentations and discussions from the 2012 National HIV Diagnostic Conference held in Atlanta (GA, USA), on 12-14 December 2012. Reflecting changes in the evolving field of HIV diagnostics, the conference provided a forum for evaluating developments in molecular diagnostics and their role in HIV diagnosis. In 2010, the HIV Diagnostics Conference concluded with the proposal of a new diagnostic algorithm which included nucleic acid testing to resolve discordant screening and supplemental antibody test results. The 2012 meeting, picking up where the 2010 meeting left off, focused on scientific presentations that assessed this new algorithm and the role played by RNA testing and new developments in molecular diagnostics, including detection of total and integrated HIV-1 DNA, detection and quantification of HIV-2 RNA, and rapid formats for detection of HIV-1 RNA.

  19. Culture-independent diagnostic testing: have we opened Pandora's box for good?

    Science.gov (United States)

    Janda, J Michael; Abbott, Sharon A

    2014-11-01

    The ability to accurately and quickly identify microbial agents associated with infectious diseases has been a longstanding and continuous goal of diagnostic microbiology laboratories. Over the course of several decades, technology and testing methodologies in this field have gradually evolved from traditional- or classic-based culture and identification approaches to antigen capture systems and more molecular-oriented applications. Recently, these molecular-based applications have signaled a new era in clinical diagnostic microbiology with the commercial introduction of culture-independent diagnostic testing (CIDT) systems. The first major commercial venture into the CIDT arena involves the detection of acute bacterial gastroenteritis. Several commercial products are now on the market globally with at least 4 Food and Drug Administration approved since January of 2013. These new systems offer the direct detection of a variety of enteropathogens quickly without the need for traditional culture. In Greek mythology, Pandora opened a "jar" or "box" out of curiosity thereby releasing all of humanity's evils most notably diseases and plagues according to Hesiod's Theogony. While not ill-intentioned the only thing left in the box was Hope. Copyright © 2014 Elsevier Inc. All rights reserved.

  20. Usage of Latent Class Analysis in Diagnostic Microbiology in the Absence of Gold Standard Test

    Directory of Open Access Journals (Sweden)

    Gul Bayram Abiha

    2016-12-01

    Full Text Available The evaluation of performance of various tests diagnostic tests in the absence of gold standard is an important problem. Latent class analysis (LCA is a statistical analysis method known for many years, especially in the absence of a gold standard for evaluation of diagnostic tests so that LCA has found its wide application area. During the last decade, LCA method has widely used in for determining sensivity and specifity of different microbiological tests. It has investigated in the diagnosis of mycobacterium tuberculosis, mycobacterium bovis, human papilloma virus, bordetella pertussis, influenza viruses, hepatitis E virus (HEV, hepatitis C virus (HCV and other various viral infections. Researchers have compared several diagnostic tests for the diagnosis of different pathogens with LCA. We aimed to evaluate performance of latent class analysis method used microbiological diagnosis in various diseases in several researches. When we took into account all of these tests' results, we suppose that LCA is a good statistical analysis method to assess different test performances in the absence of gold standard. [Archives Medical Review Journal 2016; 25(4.000: 467-488

  1. Laboratory evaluation of immunochromatographic rapid diagnostic tests for cholera in Haiti.

    Directory of Open Access Journals (Sweden)

    Wilfredo R Matias

    Full Text Available Rapid diagnostic tests (RDT for cholera are promising tools for detecting cholera in areas with limited laboratory infrastructure. However, evidence on the characteristics of the many available RDTs is scarce, and their use has been limited by suboptimal performance. We evaluated the performance characteristics of three cholera RDTs from Span Diagnostics, Artron Laboratories, and Standard Diagnostics in a regional laboratory in Haiti.We retrospectively reviewed records from May 2014 to October 2015 of a laboratory-based surveillance program for Vibrio cholerae at Hôpital Saint-Nicolas in Saint-Marc, Haiti. We compared the results of 511 Crystal VC, 129 Artron and 451 SD Bioline RDTs to bacterial culture as the gold standard. Of 905 cultures, 477 (52.7% were positive for V. cholerae O1, of which 27.7% were serotype Inaba. No cultures grew V. cholerae O139. Sensitivity and specificity of Crystal VC were 98.6% (95%CI: 96.5%-99.6% and 71.1% (95%CI: 64.7%-76.9%, respectively. Artron demonstrated a sensitivity of 98.6% (95%CI: 92.7%-100% and specificity of 69.1% (95%CI: 55.2%-80.9%. SD Bioline demonstrated a sensitivity of 81.1% (95%CI: 75.6%-85.8% and specificity of 92.8% (95%CI: 88.4%-95.9%. Crystal VC and Artron frequently showed false positive O139 bands, whereas none were seen with SD Bioline.There is significant variation in the performance of different cholera diagnostic RDTs. Artron and Crystal VC RDTs have high sensitivity and low specificity, while SD Bioline RDT has low to moderate sensitivity and high specificity when performed by laboratory technicians in Haiti. Study limitations included its retrospective design. The suboptimal characteristics of these tests limit their use as clinical point-of-care tests; however, they may be useful in outbreak response, surveillance, and research in resource-limited settings.

  2. Diagnostic accuracy of patch test in children with food allergy.

    Science.gov (United States)

    Caglayan Sozmen, Sule; Povesi Dascola, Carlotta; Gioia, Edoardo; Mastrorilli, Carla; Rizzuti, Laura; Caffarelli, Carlo

    2015-08-01

    The gold standard test for confirming whether a child has clinical hypersensitivity reactions to foods is the oral food challenge. Therefore, there is increasing interest in simpler diagnostic markers of food allergy, especially in children, to avoid oral food challenge. The goal of this study was to assess the diagnostic accuracy of atopy patch test in comparison with oral food challenge. We investigated 243 children (mean age, 51 months) referred for evaluation of suspected egg or cow's milk allergy. Skin prick test and atopy patch test were carried out, and after a 2 weeks elimination diet, oral food challenge was performed. Two hundred and forty-three children underwent OFC to the suspected food. We found clinically relevant food allergies in 40 (65%) children to egg and in 22 (35%) to cow's milk. The sensitivity of skin prick test for both milk and egg was 92%, specificity 91%, positive predictive value 35%, and negative predictive value of 93%. Sensitivity, specificity, positive predictive value, and negative predictive value of atopy patch test for both milk and egg were 21%, 73%, 20%, and 74%, respectively. Our study suggests that there is insufficient evidence for the routine use of atopy patch test for the evaluation of egg and cow's milk allergy. OFC remains gold standard for the diagnosis of egg and milk allergy even in the presence of high costs in terms of both time and risks during application. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  3. A compliance testing program for diagnostic X-ray equipment

    International Nuclear Information System (INIS)

    Hutchinson, D.E.; Cobb, B.J.; Jacob, C.S.

    1999-01-01

    Compliance testing is nominally that part of a quality assurance program dealing with those aspects of X-ray equipment performance that are subject to radiation control legislation. Quality assurance programs for medical X-ray equipment should be an integral part of the quality culture in health care. However while major hospitals and individual medical centers may implement such programs with some diligence, much X-ray equipment can remain unappraised unless there is a comprehensive regulatory inspection program or some form of compulsion on the equipment owner to implement a testing program. Since the late 1950s all X-ray equipment in the State of Western Australia has been inspected by authorized officers acting on behalf of the Radiological Council, the regulatory authority responsible for administration of the State's Radiation Safety Act. However, economic constraints, coupled with increasing X-ray equipment numbers and a geographically large State have significantly affected the inspection rate. Data available from inspections demonstrate that regular compliance and performance checks are essential in order to ensure proper performance and to minimize unnecessary patient and operator dose. To ensure that diagnostic X-ray equipment complies with accepted standards and performance criteria, the regulatory authority introduced a compulsory compliance testing program for all medical, dental and chiropractic diagnostic X-ray equipment effective from 1 January 1997

  4. Comparative analysis of two rapid diagnostic tests for diagnosis of ...

    African Journals Online (AJOL)

    This study aims at comparing the diagnostic efficiencies of two commercially available kits for detecting Plasmodium falciparum infection in urine and blood of febrile patients for malaria diagnosis. This was an observational study in which matched blood and urine from symptomatic patients were tested for malaria using two ...

  5. An audit of diagnostic tests performed in medical microbiology, and ...

    African Journals Online (AJOL)

    Clinical audit is an important tool for reviewing and improving the quality of service in clinical laboratories. This is a three year audit of diagnostic test carried out in Medical Microbiology and Immunology laboratories of University of Maiduguri Teaching Hospital, Maiduguri, Nigeria. The objectives were to document and ...

  6. Night Sleep in the Company of a Sibling Related to School Achievement.

    Science.gov (United States)

    Ong, Sara

    A single subject ABAB design was used to investigate the effect on academic achievement of altering the sleeping arrangements of a low-achieving, 9-year-old third grade male student who slept in bunk beds with an older brother aged 14 years. The subject's diagnostic test performance on reading and math measures was assessed at the beginning of the…

  7. Using Meta-Analysis to Inform the Design of Subsequent Studies of Diagnostic Test Accuracy

    Science.gov (United States)

    Hinchliffe, Sally R.; Crowther, Michael J.; Phillips, Robert S.; Sutton, Alex J.

    2013-01-01

    An individual diagnostic accuracy study rarely provides enough information to make conclusive recommendations about the accuracy of a diagnostic test; particularly when the study is small. Meta-analysis methods provide a way of combining information from multiple studies, reducing uncertainty in the result and hopefully providing substantial…

  8. An outline of possible pre-course diagnostics for differential calculus

    Directory of Open Access Journals (Sweden)

    Aneshkumar Maharaj

    2014-07-01

    Full Text Available There is a view that many first-year students lack the basic knowledge and skills expected of them to study at university level. We examined the expected work habits and pre-course diagnostics for students who choose to take a course on differential calculus. We focused on the lecturer pre-course expectations of a student in the context of work habits, knowledge and technical skills. In particular, we formulated outcomes and then sample diagnostic questions to test whether the identified learning outcomes on expected work habits and learning are in place. If students are made aware of the expected learning outcomes and if they take the diagnostic test, they should be able to achieve greater success in their studies. The validity of this assumption will be the subject of a future paper which will report on the implementation of the learning outcomes and diagnostic questions that we formulated for pre-course diagnostics in differential calculus.

  9. The diagnostic accuracy of three rapid diagnostic tests for typhoid fever at Chittagong Medical College Hospital, Chittagong, Bangladesh.

    Science.gov (United States)

    Maude, Rapeephan R; de Jong, Hanna K; Wijedoru, Lalith; Fukushima, Masako; Ghose, Aniruddha; Samad, Rasheda; Hossain, Mohammed Amir; Karim, Mohammed Rezaul; Faiz, Mohammed Abul; Parry, Christopher M

    2015-10-01

    To determine the diagnostic accuracy of three rapid diagnostic tests (RDTs) for typhoid fever in febrile hospitalised patients in Bangladesh. Febrile adults and children admitted to Chittagong Medical College Hospital, Bangladesh, were investigated with Bact/Alert(®) blood cultures and real-time PCR to detect Salmonella enterica Typhi and Paratyphi A and assays for Rickettsia, leptospirosis and dengue fever. Acute serum samples were examined with the LifeAssay (LA) Test-it™ Typhoid IgM lateral flow assay detecting IgM antibodies against S. Typhi O antigen, CTKBiotech Onsite Typhoid IgG/IgM Combo Rapid-test cassette lateral flow assay detecting IgG and IgM antibodies against S. Typhi O and H antigens and SD Bioline line assay for IgG and IgM antibodies against S. Typhi proteins. In 300 malaria smear-negative febrile patients [median (IQR) age of 13.5 (5-31) years], 34 (11.3%) had confirmed typhoid fever: 19 positive by blood culture for S. Typhi (three blood PCR positive) and 15 blood culture negative but PCR positive for S. Typhi in blood. The respective sensitivity and specificity of the three RDTs in patients using a composite reference standard of blood culture and/or PCR-confirmed typhoid fever were 59% and 61% for LifeAssay, 59% and 74% for the CTK IgM and/or IgG, and 24% and 96% for the SD Bioline RDT IgM and/or IgG. The LifeAssay RDT had a sensitivity of 63% and a specificity of 91% when modified with a positive cut-off of ≥2+ and analysed using a Bayesian latent class model. These typhoid RDTs demonstrated moderate diagnostic accuracies, and better tests are needed. © 2015 The Authors. Tropical Medicine & International Health Published by John Wiley & Sons Ltd.

  10. Systematic Review of Health Economic Evaluations of Diagnostic Tests in Brazil: How accurate are the results?

    Science.gov (United States)

    Oliveira, Maria Regina Fernandes; Leandro, Roseli; Decimoni, Tassia Cristina; Rozman, Luciana Martins; Novaes, Hillegonda Maria Dutilh; De Soárez, Patrícia Coelho

    2017-08-01

    The aim of this study is to identify and characterize the health economic evaluations (HEEs) of diagnostic tests conducted in Brazil, in terms of their adherence to international guidelines for reporting economic studies and specific questions in test accuracy reports. We systematically searched multiple databases, selecting partial and full HEEs of diagnostic tests, published between 1980 and 2013. Two independent reviewers screened articles for relevance and extracted the data. We performed a qualitative narrative synthesis. Forty-three articles were reviewed. The most frequently studied diagnostic tests were laboratory tests (37.2%) and imaging tests (32.6%). Most were non-invasive tests (51.2%) and were performed in the adult population (48.8%). The intended purposes of the technologies evaluated were mostly diagnostic (69.8%), but diagnosis and treatment and screening, diagnosis, and treatment accounted for 25.6% and 4.7%, respectively. Of the reviewed studies, 12.5% described the methods used to estimate the quantities of resources, 33.3% reported the discount rate applied, and 29.2% listed the type of sensitivity analysis performed. Among the 12 cost-effectiveness analyses, only two studies (17%) referred to the application of formal methods to check the quality of the accuracy studies that provided support for the economic model. The existing Brazilian literature on the HEEs of diagnostic tests exhibited reasonably good performance. However, the following points still require improvement: 1) the methods used to estimate resource quantities and unit costs, 2) the discount rate, 3) descriptions of sensitivity analysis methods, 4) reporting of conflicts of interest, 5) evaluations of the quality of the accuracy studies considered in the cost-effectiveness models, and 6) the incorporation of accuracy measures into sensitivity analyses.

  11. LOGICAL CONDITIONS ANALYSIS METHOD FOR DIAGNOSTIC TEST RESULTS DECODING APPLIED TO COMPETENCE ELEMENTS PROFICIENCY

    Directory of Open Access Journals (Sweden)

    V. I. Freyman

    2015-11-01

    Full Text Available Subject of Research.Representation features of education results for competence-based educational programs are analyzed. Solution importance of decoding and proficiency estimation for elements and components of discipline parts of competences is shown. The purpose and objectives of research are formulated. Methods. The paper deals with methods of mathematical logic, Boolean algebra, and parametrical analysis of complex diagnostic test results, that controls proficiency of some discipline competence elements. Results. The method of logical conditions analysis is created. It will give the possibility to formulate logical conditions for proficiency determination of each discipline competence element, controlled by complex diagnostic test. Normalized test result is divided into noncrossing zones; a logical condition about controlled elements proficiency is formulated for each of them. Summarized characteristics for test result zones are imposed. An example of logical conditions forming for diagnostic test with preset features is provided. Practical Relevance. The proposed method of logical conditions analysis is applied in the decoding algorithm of proficiency test diagnosis for discipline competence elements. It will give the possibility to automate the search procedure for elements with insufficient proficiency, and is also usable for estimation of education results of a discipline or a component of competence-based educational program.

  12. Towards Modernizing the Characterization of Shock and Detonation Physics Performance via Novel Diagnostics and Tests

    Science.gov (United States)

    Salyer, Terry

    2017-06-01

    For the bulk of detonation performance experiments, a fairly basic set of diagnostic techniques has evolved as the standard for acquiring the necessary measurements. Gold standard techniques such as pin switches and streak cameras still produce the high-quality data required, yet much room remains for improvement with regard to ease of use, cost of fielding, breadth of data, and diagnostic versatility. Over the past several years, an alternate set of diagnostics has been under development to replace many of these traditional techniques. Pulse Correlation Reflectometry (PCR) is a capable substitute for pin switches with the advantage of obtaining orders of magnitude more data at a small fraction of the cost and fielding time. Spectrally Encoded Imaging (SEI) can replace most applications of streak camera with the advantage of imaging surfaces through a single optical fiber that are otherwise optically inaccessible. Such diagnostics advance the measurement state of the art, but even further improvements may come through revamping the standardized tests themselves such as the copper cylinder expansion test. At the core of this modernization, the aforementioned diagnostics play a significant role in revamping and improving the standard test suite for the present era. This research was performed under the auspices of the United States Department of Energy.

  13. Advances in in vitro diagnostics in allergy, asthma, and immunology in 2012.

    Science.gov (United States)

    Renz, Harald

    2013-12-01

    Laboratory tests play an increasing role in risk assessment, diagnostics, and disease monitoring. Great advances have been achieved lately, particularly in the field of clinical immunology and allergy. These include neonatal screening of immunodeficiencies and asthma biomarkers and investigation into the role of recombinant allergens in in vitro testing. The latter area has implications for the diagnostics of food allergy, pollen-induced allergies, asthma, and insect allergies. Copyright © 2013 American Academy of Allergy, Asthma & Immunology. Published by Mosby, Inc. All rights reserved.

  14. Empirical evidence of design-related bias in studies of diagnostic tests

    NARCIS (Netherlands)

    Lijmer, J. G.; Mol, B. W.; Heisterkamp, S.; Bonsel, G. J.; Prins, M. H.; van der Meulen, J. H.; Bossuyt, P. M.

    1999-01-01

    CONTEXT: The literature contains a large number of potential biases in the evaluation of diagnostic tests. Strict application of appropriate methodological criteria would invalidate the clinical application of most study results. OBJECTIVE: To empirically determine the quantitative effect of study

  15. Planning for Plume Diagnostics for Ground Testing of J-2X Engines at the SSC

    Science.gov (United States)

    SaintCyr, William W.; Tejwani, Gopal D.; McVay, Gregory P.; Langford, Lester A.; SaintCyr, William W.

    2010-01-01

    John C. Stennis Space Center (SSC) is the premier test facility for liquid rocket engine development and certification for the National Aeronautics and Space Administration (NASA). Therefore, it is no surprise that the SSC will play the most prominent role in the engine development testing and certification for the J-2X engine. The Pratt & Whitney Rocketdyne J-2X engine has been selected by the Constellation Program to power the Ares I Upper Stage Element and the Ares V Earth Departure Stage in NASA s strategy of risk mitigation for hardware development by building on the Apollo program and other lessons learned to deliver a human-rated engine that is on an aggressive development schedule, with first demonstration flight in 2010 and human test flights in 2012. Accordingly, J-2X engine design, development, test, and evaluation is to build upon heritage hardware and apply valuable experience gained from past development and testing efforts. In order to leverage SSC s successful and innovative expertise in the plume diagnostics for the space shuttle main engine (SSME) health monitoring,1-10 this paper will present a blueprint for plume diagnostics for various proposed ground testing activities for J-2X at SSC. Complete description of the SSC s test facilities, supporting infrastructure, and test facilities is available in Ref. 11. The A-1 Test Stand is currently being prepared for testing the J-2X engine at sea level conditions. The A-2 Test Stand is currently being used for testing the SSME and may also be used for testing the J-2X engine at sea level conditions in the future. Very recently, ground-breaking ceremony for the new A-3 rocket engine test stand took place at SSC on August 23, 2007. A-3 is the first large - scale test stand to be built at the SSC since the A and B stands were constructed in the 1960s. The A-3 Test Stand will be used for testing J-2X engines under vacuum conditions simulating high altitude operation at approximately 30,480 m (100,000 ft

  16. An Indian test facility to characterise diagnostic neutral beam for ITER

    International Nuclear Information System (INIS)

    Singh, M.J.; Bandyopadhyay, M.; Rotti, C.; Singh, N.P.; Shah, Sejal; Bansal, G.; Gahlaut, A.; Soni, J.; Lakdawala, H.; Waghela, Harshad; Ahmed, I.; Roopesh, G.; Baruah, U.K.; Chakraborty, A.K.

    2011-01-01

    The diagnostic neutral beam (DNB) line shall be used to diagnose the He ash content in the D-T phase of the ITER machine using the charge exchange recombination spectroscopy (CXRS). Implementation of a successful DNB at ITER requires several challenges related to the production, neutralization and transport of the neutral beam over path lengths of 20.665 m, to be overcome. The delivery is aided if the above effects are tested prior to onsite commissioning. As DNB is a procurement package for INDIA, an ITER approved Indian test facility, INTF, is under construction at Institute for Plasma Research (IPR), India and is envisaged to be operational in 2015. The timeline for this facility is synchronized with the RADI, ELISE (IPP, Garching), SPIDER (RFX, Padova) in a manner that best utilization of configurational inputs available from them are incorporated in the design. This paper describes the facility in detail and discusses the experiments planned to optimise the beam transmission and testing of the beam line components using various diagnostics.

  17. [The Offer of Medical-Diagnostic Self-Tests on German Language Websites: Results of a Systematic Internet Search].

    Science.gov (United States)

    Kuecuekbalaban, P; Schmidt, S; Muehlan, H

    2018-03-01

    The aim of the current study was to provide an overview of medical-diagnostic self-tests which can be purchased without a medical prescription on German language websites. From September 2014 to March 2015, a systematic internet research was conducted with the following search terms: self-test, self-diagnosis, home test, home diagnosis, quick test, rapid test. 513 different self-tests for the diagnostics of 52 diverse diseases or health risks were identified, including chronic diseases (e. g. diabetes, chronic disease of the kidneys, liver, and lungs), sexually transmitted diseases (e. g. HIV, chlamydia, gonorrhea), infectious diseases (e. g. tuberculosis, malaria, Helicobacter pylori), allergies (e. g. house dust, cats, histamine) and cancer as well as tests for the diagnostics of 12 different psychotropic substances. These were sold by 90 companies in Germany and by other foreign companies. The number of medical-diagnostic self-tests which can be bought without a medical prescription on the Internet has increased enormously in the last 10 years. Further studies are needed for the identification of the determinants of the use of self-tests as well as the impact of the application on the experience and behavior of the user. © Georg Thieme Verlag KG Stuttgart · New York.

  18. Estimating diagnostic test accuracies for Brachyspira hyodysenteriae accounting for the complexities of population structure in food animals.

    Directory of Open Access Journals (Sweden)

    Sonja Hartnack

    Full Text Available For swine dysentery, which is caused by Brachyspira hyodysenteriae infection and is an economically important disease in intensive pig production systems worldwide, a perfect or error-free diagnostic test ("gold standard" is not available. In the absence of a gold standard, Bayesian latent class modelling is a well-established methodology for robust diagnostic test evaluation. In contrast to risk factor studies in food animals, where adjustment for within group correlations is both usual and required for good statistical practice, diagnostic test evaluation studies rarely take such clustering aspects into account, which can result in misleading results. The aim of the present study was to estimate test accuracies of a PCR originally designed for use as a confirmatory test, displaying a high diagnostic specificity, and cultural examination for B. hyodysenteriae. This estimation was conducted based on results of 239 samples from 103 herds originating from routine diagnostic sampling. Using Bayesian latent class modelling comprising of a hierarchical beta-binomial approach (which allowed prevalence across individual herds to vary as herd level random effect, robust estimates for the sensitivities of PCR and culture, as well as for the specificity of PCR, were obtained. The estimated diagnostic sensitivity of PCR (95% CI and culture were 73.2% (62.3; 82.9 and 88.6% (74.9; 99.3, respectively. The estimated specificity of the PCR was 96.2% (90.9; 99.8. For test evaluation studies, a Bayesian latent class approach is well suited for addressing the considerable complexities of population structure in food animals.

  19. Alkaline Comet Assay and Micronucleus Test Parameters in Children Exposed to Diagnostic X-Ray Examination

    International Nuclear Information System (INIS)

    Gajski, G.; Geric, M.; Garaj-Vrhovac, V.; Milkovic, Dj.; Beck, N.; Ranogajec-Komor, M.; Miljanic, S.; Knezevic, Z.

    2011-01-01

    Chest radiograms represent the basic radiological examination of thorax and are the most frequently performed radiological diagnostic procedure in the child population. Understanding the risks of low doses of radiation is an important aspect in the risk benefit analysis in paediatric populations. To provide the best care for the young patients the effects of radiation should be minimized thus chest X-rays must be performed by highest standards to ensure that the young patient has the lowest risk possible. Since children are the most sensitive to radiation, there is a need for follow up of the young populations that receive these X-ray diagnostic examinations. Follow up would be especially advisable for children that are at higher risk of radiation induced damage, for example children with a predisposition to DNA damage, or for children that are constantly exposed to numerous radiological examinations due to their illness. In that manner, present study was undertaken to evaluate application of different dosimetry systems in conjunction with alkaline comet assay and micronucleus test for the assessment of different types of DNA and chromosomal alterations in child population exposed to acute diagnostic X-rays examination. For that purpose doses were measured using thermoluminescence (TL) and radiophotoluminescent (RPL) dosimetry systems. The study demonstrated that immediately after exposure to diagnostic X-irradiation, mean percentage of DNA in tail of the comets, which is indirect measures of DNA damage, was significantly changed. The same was noticed for mean total number of micronuclei as well. It was shown that children with pulmonary diseases subjected to diagnostic procedure develop a significant increase in mean total number of each measured parameter which are the biomarkers of genetic damage for carcinogenesis, than prior to diagnostic procedure and that interindividual differences exist for each monitored child. Our results show that genetic damage arises

  20. [Critical reading of articles about diagnostic tests (part I): Are the results of the study valid?].

    Science.gov (United States)

    Arana, E

    2015-01-01

    In the era of evidence-based medicine, one of the most important skills a radiologist should have is the ability to analyze the diagnostic literature critically. This tutorial aims to present guidelines for determining whether primary diagnostic articles are valid for clinical practice. The following elements should be evaluated: whether the study can be applied to clinical practice, whether the technique was compared to the reference test, whether an appropriate spectrum of patients was included, whether expectation bias and verification bias were limited, the reproducibility of the study, the practical consequences of the study, the confidence intervals for the parameters analyzed, the normal range for continuous variables, and the placement of the test in the context of other diagnostic tests. We use elementary practical examples to illustrate how to select and interpret the literature on diagnostic imaging and specific references to provide more details. Copyright © 2014 SERAM. Published by Elsevier España, S.L.U. All rights reserved.

  1. A hybrid model for combining case-control and cohort studies in systematic reviews of diagnostic tests

    Science.gov (United States)

    Chen, Yong; Liu, Yulun; Ning, Jing; Cormier, Janice; Chu, Haitao

    2014-01-01

    Systematic reviews of diagnostic tests often involve a mixture of case-control and cohort studies. The standard methods for evaluating diagnostic accuracy only focus on sensitivity and specificity and ignore the information on disease prevalence contained in cohort studies. Consequently, such methods cannot provide estimates of measures related to disease prevalence, such as population averaged or overall positive and negative predictive values, which reflect the clinical utility of a diagnostic test. In this paper, we propose a hybrid approach that jointly models the disease prevalence along with the diagnostic test sensitivity and specificity in cohort studies, and the sensitivity and specificity in case-control studies. In order to overcome the potential computational difficulties in the standard full likelihood inference of the proposed hybrid model, we propose an alternative inference procedure based on the composite likelihood. Such composite likelihood based inference does not suffer computational problems and maintains high relative efficiency. In addition, it is more robust to model mis-specifications compared to the standard full likelihood inference. We apply our approach to a review of the performance of contemporary diagnostic imaging modalities for detecting metastases in patients with melanoma. PMID:25897179

  2. Beam diagnostic tools for the negative hydrogen ion source test facility ELISE

    International Nuclear Information System (INIS)

    Nocentini, Riccardo; Fantz, Ursel; Franzen, Peter; Froeschle, Markus; Heinemann, Bernd; Riedl, Rudolf; Ruf, Benjamin; Wuenderlich, Dirk

    2013-01-01

    Highlights: ► We present an overview of beam diagnostic tools foreseen for the new testbed ELISE. ► A sophisticated diagnostic calorimeter allows beam profile measurement. ► A tungsten wire mesh in the beam path provides a qualitative picture of the beam. ► Stripping losses and beam divergence are measured by H α Doppler shift spectroscopy. -- Abstract: The test facility ELISE, presently being commissioned at IPP, is a first step in the R and D roadmap for the RF driven ion source and extraction system of the ITER NBI system. The “half-size” ITER-like test facility includes a negative hydrogen ion source that can be operated for 1 h. ELISE is expected to extract an ion beam of 20 A at 60 kV for 10 s every 3 min, therefore delivering a total power of 1.2 MW. The extraction area has a geometry that closely reproduces the ITER design, with the same width and half the height, i.e. 1 m × 1 m. This paper presents an overview of beam diagnostic tools foreseen for ELISE. For the commissioning phase, a simple beam dump with basic diagnostic capabilities has been installed. In the second phase, the beam dump will be substituted by a more sophisticated diagnostic calorimeter to allow beam profile measurement. Additionally, a tungsten wire mesh will be introduced in the beam path to provide a qualitative picture of beam size and position. Stripping losses and beam divergence will be measured by means of H α Doppler shift spectroscopy. An absolute calibration is foreseen in order to measure beam intensity

  3. Assessment of the Diagnostic Potential of Clinotech TB Screen Test ...

    African Journals Online (AJOL)

    The Clinotech TB Screen test, a 3rd generation multi-antigen rapid chromatographic immunoassay for detection of IgG antibodies in serum against recombinant protein antigens 38kDa, 16kDa and 6kDa, was assessed for its diagnostic potential for diagnosis of active pulmonary TB in routine TB control programme in Abia ...

  4. Interlaboratory comparison and accreditation in quality control testing of diagnostic X-ray equipment

    International Nuclear Information System (INIS)

    Kepler, K.; Vladimirov, A.; Servomaa, A.

    2005-01-01

    The Univ. of Tartu provides a quality control service to the majority of diagnostic X-ray departments in Estonia. Its methodology has been adopted from the IEC and other relevant standards. Recently the Testing Centre of the Univ. of Tartu was accredited on this methodology by ISO/IEC 17025. Besides the implementation of the quality management system, participation in interlaboratory comparison (ILC) was one of the prerequisites for the accreditation. Tests for estimating reproducibility of tube voltage and dose rate, accuracy of the voltage and accuracy of exposure time were carried out on a diagnostic X-ray unit in the Radiation and Nuclear Safety Authority in Helsinki. The measurement performance was judged by calculating deviation En normalised with respect to the stated uncertainties. En values for all tests were less than unity and by the common ILC criteria the testing performance could be considered as acceptable. (authors)

  5. The psychological impact of test results following diagnostic coronary CT angiography.

    Science.gov (United States)

    Devcich, Daniel A; Ellis, Christopher J; Broadbent, Elizabeth; Gamble, Greg; Petrie, Keith J

    2012-11-01

    Coronary computed tomography (CT) angiography is an advanced cardiac imaging test commonly used for diagnosing early signs of ischemic heart disease. Despite its importance in cardiology, little is known about its psychological effect on patients. The present study sought to examine these effects in relation to illness perceptions, cardiac health behavior intentions, and subsequent health behaviors. Forty-five nonacute cardiac patients who were referred for diagnostic coronary CT angiography completed questionnaires prior to testing and following the receipt of test results, at which point illness perceptions and intentions to take cardiac medication, as well as diet and exercise intentions were measured. Exercise and dietary behaviors were measured at follow-up 6 weeks later. Changes on these variables were then compared between patients diagnosed with normal arteries and patients diagnosed with diseased arteries. Compared to positive-testing patients, patients with normal test results reported significant changes toward more positive illness perceptions following testing, with improvements in emotional effect of illness, illness concern, consequences, and personal control of illness. The illness perception of treatment control was seen as more important among positive-testing patients, whereas both groups reported increases in illness coherence. Health behavior intentions (cardiac medication intentions and exercise intentions) increased for positive-testing patients only, as did physical activity at follow-up. Diagnosis-dependent psychological effects can be detected following coronary CT angiography. These effects have important implications for patient health and health care in diagnostic contexts, and the results from this study can be used to guide further research in this area.

  6. Diagnostic accuracy and optimal use of three tests for tuberculosis in live badgers.

    Directory of Open Access Journals (Sweden)

    Julian A Drewe

    Full Text Available BACKGROUND: Accurate diagnosis of tuberculosis (TB due to infection with Mycobacterium bovis is notoriously difficult in live animals, yet important if we are to understand the epidemiology of TB and devise effective strategies to limit its spread. Currently available tests for diagnosing TB in live Eurasian badgers (Meles meles remain unvalidated against a reliable gold standard. The aim of the present study was to evaluate the diagnostic accuracy and optimal use of three tests for TB in badgers in the absence of a gold standard. METHODOLOGY/PRINCIPAL FINDINGS: A Bayesian approach was used to evaluate the diagnostic accuracy and optimal use of mycobacterial culture, gamma-interferon assay and a commercially available serological test using multiple samples collected from 305 live wild badgers. Although no single test was judged to be sufficiently sensitive and specific to be used as a sole diagnostic method, selective combined use of the three tests allowed guidelines to be formulated that allow a diagnosis to be made for individual animals with an estimated overall accuracy of 93% (range: 75% to 97%. Employing this approach in the study population of badgers resulted in approximately 13 out of 14 animals having their true infection status correctly classified from samples collected on a single capture. CONCLUSIONS/SIGNIFICANCE: This method of interpretation represents a marked improvement on the current procedure for diagnosing M. bovis infection in live badgers. The results should be of use to inform future test and intervention strategies with the aim of reducing the incidence of TB in free-living wild badger populations.

  7. Consensus based reporting standards for diagnostic test accuracy studies for paratuberculosis in ruminants.

    NARCIS (Netherlands)

    Gardner, I.A.; Nielsen, S.S.; Whittington, R.J.; Collins, M.T.; Bakker, D.; Harris, B.; Sreevatsan, S.; Lombard, J.E.; Sweeney, R.; Smith, D.R.; Gavalchin, J.; Eda, S.

    2011-01-01

    The Standards for Reporting of Diagnostic Accuracy (STARD) statement (www.stard-statement.org) was developed to encourage complete and transparent reporting of key elements of test accuracy studies in human medicine. The statement was motivated by widespread evidence of bias in test accuracy studies

  8. Diagnostic tests for Helicobacter pylori : A prospective evaluation of their accuracy, without selecting a single test as the gold standard

    NARCIS (Netherlands)

    Thijs, J C; van Zwet, A A; Thijs, W J; Oey, H B; Karrenbeld, A; Stellaard, F; Luijt, D S; Meyer, B C; Kleibeuker, J H

    1996-01-01

    OBJECTIVE: To assess the accuracy of six commonly used diagnostic tests for Helicobacter pylori in a prospective study without using any specific test as the gold standard (the patient was regarded as H. pylori-infected if two or more tests, whatever their nature, were positive). METHODS: In 105

  9. Test Anxiety and Academic Performance among Undergraduates: The Moderating Role of Achievement Motivation.

    Science.gov (United States)

    Balogun, Anthony Gbenro; Balogun, Shyngle Kolawole; Onyencho, Chidi Victor

    2017-02-13

    This study investigated the moderating role of achievement motivation in the relationship between test anxiety and academic performance. Three hundred and ninety three participants (192 males and 201 females) selected from a public university in Ondo State, Nigeria using a purposive sampling technique, participated in the study. They responded to measures of test anxiety and achievement motivation. Three hypotheses were tested using moderated hierarchical multiple regression analysis. Results showed that test anxiety had a negative impact on academic performance (β = -.23; p motivation had a positive impact on academic performance (β = .38; p motivation significantly moderated the relationship between test anxiety and academic performance (β = .10; p students' achievement motivation.

  10. Continuous-data diagnostic tests for paratuberculosis as a multistage disease

    DEFF Research Database (Denmark)

    Toft, Nils; Nielsen, Søren Saxmose; Jørgensen, Erik

    2005-01-01

    We devised a general method for interpretation of multistage diseases using continuous-data diagnostic tests. As an example, we used paratuberculosis as a multistage infection with 2 stages of infection as well as a noninfected state. Using data from a Danish research project, a fecal culture...... testing scheme was linked to an indirect ELISA and adjusted for covariates (parity, age at first calving, and days in milk). We used the log-transformed optical densities in a Bayesian network to obtain the probabilities for each of the 3 infection stages for a given optical density (adjusted...... for covariates). The strength of this approach was that the uncertainty associated with a test was imposed directly on the individual test result rather than aggregated into the population-based measures of test properties (i.e., sensitivity and specificity)...

  11. The diagnostic effects of s-TSH and TRH stimulating test on subclinical thyroid function

    International Nuclear Information System (INIS)

    Lu Shujun; Wang Wenliang; Lu Shuyan; Zheng Linong; Hu Changjun; Fang Xiaozheng; Zheng Huian; Ma Meizhen

    2002-01-01

    The study was carried out to investigate the diagnostic effects of supersensitive TSH on diagnosing subclinical thyroid function with only once s-TSH detection and with TRH stimulating tests. TRH stimulating tests have been undertaken for 90 patients with different thyroid disease and 58 normal subjects. Diagnostic basal levels of s-TSH test in control group, subclinical hyperthyroidism group and subclinical hypothyroidism group were 2.20 +- 1.85 mIU/L, 0.54 +- 0.3 mIU/L and 9.08 +- 6.3 mIU/L, respectively, the levels of subclinical hyperthyroidism and subclinical hypothyroidism group were significantly higher than that of normal subjects group (P s -TSH>30 mIU/L. Dynamic observing of TRH stimulating tests have more effect than that of only once s-TSH detection in diagnosing subclinical thyroid function

  12. Protease activity measurement in milk as a diagnostic test for clinical mastitis in dairy cows

    NARCIS (Netherlands)

    Koop, G.; van Werven, T.; Roffel, S.; Hogeveen, H.; Nazmi, K.; Bikker, F.J.

    2015-01-01

    Due to the increasing use of automated milking systems, automated detection of clinical mastitis is becoming more important. Various in- or on-line diagnostic tests are in use, but generally suffer from false mastitis alerts. In this study, we explored a new diagnostic approach based on measurement

  13. Component-resolved diagnostics in vernal conjunctivitis.

    Science.gov (United States)

    Armentia, Alicia; Sanchís, Eugenia; Montero, Javier A

    2016-10-01

    Conventional diagnostic tests in allergy are insufficient to clarify the cause of vernal conjunctivitis. Component-resolved diagnostic (CRD) by microarray allergen assay may be useful in detecting allergens that might be involved in the inflammatory process. In a recent trial in patients suffered from eosinophilic esophagitis, after 2 years of the CRD-guided exclusion diet and specific immunotherapy, significant clinical improvement was observed, and 68% of patients were discharged (cure based on negative biopsy, no symptoms, and no medication intake). Our new objective was to evaluate IgE-mediated hypersensitivity by CRD in tears and serum from patients with vernal conjunctivitis and treat patients with identified triggering allergens by specific immunotherapy. Twenty-five patients with vernal conjunctivitis were evaluated. The identified triggering allergens were n Lol p 1 (11 cases), n Cyn d 1 (eight cases), group 4 and 6 grasses (six cases) and group 5 of grasses (five cases). Prick test and pollen IgE were positive in one case. Clinical improvement was observed in 13/25 vernal conjunctivitis patients after 1-year specific immunotherapy. CRD seems to be a more sensitive diagnostic tool compared with prick test and IgE detection. Specific CRD-led immunotherapy may achieve clinical improvements in vernal conjunctivitis patients.

  14. The furosemide diagnostic test in suspected slow-onset heart failure : popular but not useful

    NARCIS (Netherlands)

    Kelder, Johannes C.; Cramer, Maarten J.; Rutten, Frans H.; Plokker, H. W.; Grobbee, Diederick E.; Hoes, Arno W.

    Aims Early, slow-onset heart failure is difficult to diagnose from just signs and symptoms. The physician needs ancillary diagnostic tests. The 'loop-diuretic test' or 'furosemide test', characterized as weight loss and alleviation of symptoms after a short course of a loop-diuretic, could be a

  15. Structured approach to design of diagnostic test evaluation studies for chronic progressive infections in animals

    DEFF Research Database (Denmark)

    Nielsen, Søren Saxmose; Toft, Nils; Gardner, Ian Andrew

    2011-01-01

    Diagnostic test evaluations (DTEs) for chronic infections are challenging because a protracted incubation period has to be considered in the design of the DTE, and the adverse effects of infection may be widespread and progressive over an animal's entire life. Frequently, the specific purpose......) than originally intended. The objective of this paper is to outline a structured approach to the design and conduct of a DTE for diagnostic tests used for chronic infections in animals, and intended for different purposes. We describe the process from reflections about test purpose and the underlying...... of the test is not formally considered when a test is evaluated. Therefore, the result is often a DTE where test sensitivity and specificity estimates are biased, either because of problems with establishing the true infection status or because the test detects another aspect of the infection (and analyte...

  16. Diagnostic Tests for The Control of Foot and Mouth Disease: An ...

    African Journals Online (AJOL)

    This paper describes the various diagnostic tests available for FMD, the limitations of each and their potential application in a low technology setting. The need to have complementary field and laboratory operations including suitable samples and transport methods are discussed, and examples are given. The importance of ...

  17. The introduction of compulsory compliance testing of medical diagnostic x-ray equipment in Western Australia

    International Nuclear Information System (INIS)

    Rafferty, M. W.; Jacob, C. S.

    1995-01-01

    Performance testing of medical diagnostic X-ray equipment can reveal equipment faults which, while not always clinically detectable, may contribute to reduced image quality and unnecessary radiation exposure of both patients and staff. Routine testing of such equipment is highly desirable to identify such faults and allows them to be rectified. The Radiological council of Western Australia is moving towards requiring compulsory compliance testing of all (new and existing) medical diagnostic X-ray equipment that all new mobile radiographic and new mammographic X-ray equipment be issued with a compliance test certificate as a prerequisite for registration. Workbooks which provide details of the tests required and recommended test methods have been prepared for medical radiographic (mobile and fixed), fluoroscopic and mammographic X-ray equipment. It is intended that future workbooks include details of the tests and methods for dental and computed tomography X-ray units. The workbooks are not limited to the compliance testing of items as specified in the Regulations, but include tests for other items such as film processing, darkrooms and image quality (for fluoroscopic equipment). Many of the workbook tests could be used within a regular quality assurance program for diagnostic X-ray equipment. Persons who conduct such compliance tests will need to be licensed and have all test certificates endorsed by a qualified expert. Suitable training and assessment of compliance testers will be required. Notification of such tests (including non-compliant items and corrective actions taken) will be required by the Radiological Council as a condition of equipment registration. 9 refs

  18. Pearls and pitfalls of allergy diagnostic testing: report from the American College of Allergy, Asthma and Immunology/American Academy of Allergy, Asthma and Immunology Specific IgE Test Task Force.

    Science.gov (United States)

    Cox, Linda; Williams, Brock; Sicherer, Scott; Oppenheimer, John; Sher, Larry; Hamilton, Robert; Golden, David

    2008-12-01

    The intended purpose of this monograph is to provide a general overview of allergy diagnostics for health care professionals who care for patients with allergic disease. For a more comprehensive review of allergy diagnostic testing, readers can refer to the Allergy Diagnostic Practice Parameters. A key message is that a positive allergy test result (skin or blood) indicates only the presence of allergen specific IgE (called sensitization). It does not necessarily mean clinical allergy (ie, allergic symptoms with exposure). It is important for this reason that the allergy evaluation be based on the patient's history and directed by a health care professional with sufficient understanding of allergy diagnostic testing to use the information obtained from his/her evaluation of the patient to determine (1) what allergy diagnostic tests to order, (2) how to interpret the allergy diagnostic test results, and (3) how to use the information obtained from the allergy evaluation to develop an appropriate therapeutic treatment plan.

  19. The relation between math self-concept, test and math anxiety, achievement motivation and math achievement in 12 to 14-year-old typically developing adolescents

    OpenAIRE

    Timmerman, H.L.; Toll, S.W.M.; van Luit, J.E.H.

    2017-01-01

    :This study examines the relation between math self-concept, test and math anxiety, achievement motivation, and math achievement in typically developing 12 to 14-year-old adolescents (N = 108) from a school for secondary education in the Netherlands. Data was obtained using a math speed test, achievement motivation test, and the math experience questionnaire. A significant positive correlation was found between math self-concept and math achievement in all four math domains (measurement, rela...

  20. 42 CFR 415.180 - Teaching setting requirements for the interpretation of diagnostic radiology and other diagnostic...

    Science.gov (United States)

    2010-10-01

    ... interpretation of diagnostic radiology and other diagnostic tests. 415.180 Section 415.180 Public Health CENTERS... for the interpretation of diagnostic radiology and other diagnostic tests. (a) General rule. Physician fee schedule payment is made for the interpretation of diagnostic radiology and other diagnostic tests...

  1. [Pilot tests using molecular diagnostic assay cervicovaginal infection during pregnancy].

    Science.gov (United States)

    Beltrán-Montoya, J; Escudero-Gontes, S; Martínez-Huerta, N E; Ávila-Vergara, M A; Morales-Hernández, V; Canchola-Sotelo, C; Palacios-González, B; Vadillo-Ortega, F

    2016-08-01

    The prevalence of cervicovaginal infections during pregnancy has been associated with adverse perinatal outcomes however, the actual approach used for diagnosis is not effective. The aim of this study was to compare the diagnosis of vaginal infections in pregnant women using clinical, molecular diagnostic and traditional microbiological culture in a pilot study, to determine the prevalence and association with the development of preterm labor. We performed a nested cross-sectional study composed by 54 women in a cohort of pregnant women in Mexico City. Cervicovaginal infections were evaluated by clinical methods, microbiology culture and a commercially available molecular biology test. Prevalence of cervicovaginal infections during pregnancy was estimated between 28% and 50% according to methodologies. Considering the clinical diagnosis of preterm labor as the gold standard, all diagnostic tests were poor as predictors of preterm labor. Traditional approaches to establish the significance of cervicovaginal infection in pregnancy are exhausted, so be sought new ways to understand this complex relationship. Meanwhile it is recommended to continue to use traditional methods to identify infections during pregnancy in both knowledge of new methods aimed at understanding these relationships are sophisticated.

  2. [Joint diagnostic value of four temperature sensation tests in elderly patients with type 2 diabetic peripheral neuropathy].

    Science.gov (United States)

    Guo, Wei; Li, Yun-Ming; Ai, Zhi-Hua; You, Zhi-Qing; Wan, Yong; Cheng, Ying; Lang, Hong-Mei

    2013-07-01

    To explore the joint diagnostic value of four temperature sensation tests in elderly patients with type 2 diabetic peripheral neuropathy. Thermal sensory analyzer-II were applied to measure cool sensation (CS), warm sensation (WS), cold pain sensation (CP)and heat pain sensation (HP) of 308 elderly patients with type 2 diabetes. Logistic regression model was adopted to create the new variable Temp4 from four temperature sensation tests to diagnose type 2 diabetic peripheral neuropathy. The ROC curve analysis was used to determine the best cut-off points of the four temperature sensation and Temp4, and the diagnostic value of it was evaluated. The means of temperature sensation tests of the diabetic peripheral neuropathy (DPN) group were significantly different from those of the non-DPN group (P sensation tests to diagnose the DPN, the sensitivity of WS test was the highest, and the value was 0.710; but the specificity, positive predictive value, negative predictive value, Youden index, diagnostic accuracy and Kappa value of cold sensation test were the highest, and the values were 0.842, 0.746, 0.799, 0.528, 77.92% and 0.535, respectively; the Kappa values of the other three temperature sensation tests were all greater than 0.4 (P sensation tests (P sensation quantitative tests were in good agreementand could be applied to diagnose DPN; the new variable Temp4 could be used for diagnosis of DPN with a higher diagnostic accuracy.

  3. Review: Diagnostic accuracy of PCR-based detection tests for Helicobacter Pylori in stool samples.

    Science.gov (United States)

    Khadangi, Fatemeh; Yassi, Maryam; Kerachian, Mohammad Amin

    2017-12-01

    Although different methods have been established to detect Helicobacter pylori (H. pylori) infection, identifying infected patients is an ongoing challenge. The aim of this meta-analysis was to provide pooled diagnostic accuracy measures for stool PCR test in the diagnosis of H. pylori infection. In this study, a systematic review and meta-analysis were carried out on various sources, including MEDLINE, Web of Sciences, and the Cochrane Library from April 1, 1999, to May 1, 2016. This meta-analysis adheres to the guidelines provided by the Preferred Reporting Items for Systematic Reviews and Meta-Analyses report (PRISMA Statement). The clinical value of DNA stool PCR test was based on the pooled false positive, false negative, true positive, and true negative of different genes. Twenty-six of 328 studies identified met the eligibility criteria. Stool PCR test had a performance of 71% (95% CI: 68-73) sensitivity, 96% (95% CI: 94-97) specificity, and 65.6 (95% CI: 30.2-142.5) diagnostic odds ratio (DOR) in diagnosis of H. pylori. The DOR of genes which showed the highest performance of stool PCR tests was as follows: 23S rRNA 152.5 (95% CI: 55.5-418.9), 16S rRNA 67.9 (95%CI: 6.4-714.3), and glmM 68.1 (95%CI: 20.1-231.7). The sensitivity and specificity of stool PCR test are relatively in the same spectrum of other diagnostic methods for the detection of H. pylori infection. In descending order of significance, the most diagnostic candidate genes using PCR detection were 23S rRNA, 16S rRNA, and glmM. PCR for 23S rRNA gene which has the highest performance could be applicable to detect H. pylori infection. © 2017 John Wiley & Sons Ltd.

  4. Results of metallographical diagnostic examination of Navy half-watt thermoelectric converters degraded by accelerated tests

    International Nuclear Information System (INIS)

    Rosell, F.E. Jr.; Rouklove, P.G.

    1977-01-01

    To verify the 15-year reliability of the Navy half-watt radioisotope thermoelectric generator (RTG), bismuth--telluride thermoelectric converters were submitted to testing at high temperatures which accelerated the degradation and caused failure of the converters. Metallographic diagnostic examination of failed units verified failure mechanisms. Results of diagnostic examinations are presented

  5. Beam-Based Diagnostics of RF-Breakdown in the Two-Beam Test-Stand in CTF3

    CERN Document Server

    Johnson, M

    2007-01-01

    The general outline of a beam-based diagnostic method of RF-breakdown, using BPMs, at the two-beam test-stand in CTF3 is discussed. The basic components of the set-up and their functions in the diagnostic are described. Estimations of the expected error in the measured parameters are performed.

  6. Estimating the true accuracy of diagnostic tests for dengue infection using bayesian latent class models.

    Directory of Open Access Journals (Sweden)

    Wirichada Pan-ngum

    Full Text Available Accuracy of rapid diagnostic tests for dengue infection has been repeatedly estimated by comparing those tests with reference assays. We hypothesized that those estimates might be inaccurate if the accuracy of the reference assays is not perfect. Here, we investigated this using statistical modeling.Data from a cohort study of 549 patients suspected of dengue infection presenting at Colombo North Teaching Hospital, Ragama, Sri Lanka, that described the application of our reference assay (a combination of Dengue IgM antibody capture ELISA and IgG antibody capture ELISA and of three rapid diagnostic tests (Panbio NS1 antigen, IgM antibody and IgG antibody rapid immunochromatographic cassette tests were re-evaluated using bayesian latent class models (LCMs. The estimated sensitivity and specificity of the reference assay were 62.0% and 99.6%, respectively. Prevalence of dengue infection (24.3%, and sensitivities and specificities of the Panbio NS1 (45.9% and 97.9%, IgM (54.5% and 95.5% and IgG (62.1% and 84.5% estimated by bayesian LCMs were significantly different from those estimated by assuming that the reference assay was perfect. Sensitivity, specificity, PPV and NPV for a combination of NS1, IgM and IgG cassette tests on admission samples were 87.0%, 82.8%, 62.0% and 95.2%, respectively.Our reference assay is an imperfect gold standard. In our setting, the combination of NS1, IgM and IgG rapid diagnostic tests could be used on admission to rule out dengue infection with a high level of accuracy (NPV 95.2%. Further evaluation of rapid diagnostic tests for dengue infection should include the use of appropriate statistical models.

  7. Comparison of a New and Rapid Method: Brucella Coombs Gel Test With Other Diagnostic Tests.

    Science.gov (United States)

    Kalem, Fatma; Ergün, Ayşe Gül; Durmaz, Süleyman; Doğan, Metin; Ertuğrul, Ömür; Gündem, Seval

    2016-09-01

    The aim of this study was to detect reliability of Brucella Coombs gel test (BCGT) by comparing with with ELISA (IgG + IgM), Standard agglutination test, and Brucella immunocapture agglutination methods in serological diagnosis of brucellosis. Brucella Coombs gel test (BCGT), Brucella ELISA (IgG + IgM), Standard agglutination test, and Brucella immunocapture agglutination tests of 78 patients with presumptive diagnosis of brucellosis which were sent to Microbiology Laboratory of Konya Numune Hospital from various regions of Konya were studied. Of 78 patients with ELISA IgG and IgM, STA, BICA and BCGT; 26, 21, 10, 12 and 12 were positive. When compared with BICA, the sensitivity and specifity of BCGT were 100% and 100%, respectively. According to results BCGT can be used as a diagnostic test in routine laboratories after more comprehensive studies in control groups and patients. © 2016 Wiley Periodicals, Inc.

  8. Achievement Goals as Mediators of the Relationship between Competence Beliefs and Test Anxiety

    Science.gov (United States)

    Putwain, David W.; Symes, Wendy

    2012-01-01

    Background: Previous work suggests that the expectation of failure is related to higher test anxiety and achievement goals grounded in a fear of failure. Aim: To test the hypothesis, based on the work of Elliot and Pekrun (2007), that the relationship between perceived competence and test anxiety is mediated by achievement goal orientations.…

  9. [Diagnostic capacity of skin prick test in egg and cow's milk allergic infants].

    Science.gov (United States)

    Yan, Jun-mei; Chen, Jing; Li, Hai-qi; Hu, Yan

    2011-05-01

    Mean diameter is the most common used parameter for wheal response assessment after skin prick test. This study aimed to investigate the diagnostic capacity of mean diameter according to the outcome of oral food challenge, and to determine the cut-off points that could render food challenges unnecessary. Data of 173 children referred to the Division of Primary Child Health Care for the evaluation of suspected food allergy were prospectively studied. All children underwent skin prick test and open food challenge to the relevant food(s) in clinic. The mean wheal diameter of skin prick test was measured, and open food challenge was performed to confirm food allergy. The SPSS software package version 13.0 for windows (SPSS, Chicago, IL, USA) was used for all statistical analysis. Open food challenge was taken as the gold standard for diagnosis. Diagnostic capacity of skin prick test, including the sensitivity, specificity, positive predictive value, negative predictive value, was calculated by cross-table. In addition, receiver operating characteristic curve (ROC) was plotted and area under the curve (AUC) was calculated to quantify the accuracy of the parameter. For the 173 children, 271 open food challenges were performed with egg white, egg yolk and cow's milk, In which 123 were positive, 99 children were diagnosed as food allergy. Cutaneous symptoms (87.0%) were most common, followed by gastrointestinal symptoms (9.8%). The AUC of mean diameter was 0.794 for egg white, 0.804 for egg yolk and 0.904 for cow's milk. The sensitivity of skin prick test with a cut-off value of ≥ 3 mm was ranged from 71% to 87%, while the specificity was between 31% and 57%. The authors also defined food specific skin prick test mean diameters that were 100% diagnostic for allergy to egg white (≥ 8.5 mm), egg yolk (≥ 5.5 mm), cow's milk (≥ 5.5 mm). Predictive decision points for a positive outcome of food challenges can be calculated for egg and cow's milk using mean diameter. It

  10. ACER Chemistry Test Item Collection. ACER Chemtic Year 12.

    Science.gov (United States)

    Australian Council for Educational Research, Hawthorn.

    The chemistry test item banks contains 225 multiple-choice questions suitable for diagnostic and achievement testing; a three-page teacher's guide; answer key with item facilities; an answer sheet; and a 45-item sample achievement test. Although written for the new grade 12 chemistry course in Victoria, Australia, the items are widely applicable.…

  11. Accuracy of different diagnostic tests for early, delayed and late prosthetic joint infection.

    Science.gov (United States)

    Fernández-Sampedro, M; Fariñas-Alvarez, C; Garces-Zarzalejo, C; Alonso-Aguirre, M A; Salas-Venero, C; Martínez-Martínez, L; Fariñas, M C

    2017-08-25

    A combination of laboratory, histopathological and microbiological tests for diagnosis of prosthetic joint infection (PJI) have been strongly recommended. This study aims to characterize the accuracy of individual or group tests, such as culture of sonicate fluid, synovial fluid and peri-implant tissue, C-reactive protein (CRP) and histopathology for detection of early, delayed and late PJI. A prospective study of patients undergoing hip or knee arthroplasty from February 2009 to February 2014 was performed in a Spanish tertiary health care hospital. The diagnostic accuracy of the different methods was evaluated constructing receiver-operating-characteristic (ROC) curve areas. One hundred thirty consecutive patients were included: 18 (13.8%) early PJI, 35 (27%) delayed PJI and 77 (59.2%) late PJI. For individual parameters, the area under the ROC curve for peri-implant tissue culture was larger for early (0.917) than for delayed (0.829) and late PJI (0.778), p = 0.033. There was a significantly larger difference for ROC area in the synovial fluid culture for delayed (0.803) than for early (0.781) and late infections (0.679), p = 0.039. The comparison of the areas under the ROC curves for the two microbiological tests showed that sonicate fluid was significantly different from peri-implant tissue in delayed (0.951 vs 0.829, p = 0.005) and late PJI (0.901 vs 0.778, p = 0.000). The conjunction of preoperative parameters, synovial fluid culture and CRP, improved the accuracy for late PJI (p = 0.01). The conjunction of histopathology and sonicate fluid culture increased the area under ROC curve of sonication in early (0.917 vs 1.000); p = 0.06 and late cases (0.901 vs 0.999); p < 0.001. For early PJI, sonicate fluid and peri-implant tissue cultures achieve the same best sensitivity. For delayed and late PJI, sonicate fluid culture is the most sensitive individual diagnostic method. By combining histopathology and peri-implant tissue, all early, 97% of

  12. Diagnostic efficacy of in vitro methods vs. skin testing in patients with inhalant allergies

    International Nuclear Information System (INIS)

    Corey, J.P.; Liudahl, J.J.; Young, S.A.; Rodman, S.M.

    1991-01-01

    The purpose of our study was to investigate the diagnostic efficacy of two selected methods of in vitro allergy testing. Specifically, the PRIST/modified RAST I125 isotope systems and the Quantizyme/modified EAST alkaline phosphatase method were compared. The time, expense, convenience, and diagnostic efficacy of the two procedures are discussed. Special attention is given to the practicality of each method for the practicing physician

  13. Single and Combined Diagnostic Value of Clinical Features and Laboratory Tests in Acute Appendicitis

    NARCIS (Netherlands)

    Laméris, Wytze; van Randen, Adrienne; Go, Peter M. N. Y. H.; Bouma, Wim H.; Donkervoort, Sandra C.; Bossuyt, Patrick M. M.; Stoker, Jaap; Boermeester, Marja A.

    2009-01-01

    Objectives: The objective was to evaluate the diagnostic accuracy of clinical features and laboratory test results in detecting acute appendicitis. Methods: Clinical features and laboratory test results were prospectively recorded in a consecutive series of 1,101 patients presenting with abdominal

  14. Diagnostic Accuracy of Molecular Amplification Tests for Human African Trypanosomiasis-Systematic Review

    NARCIS (Netherlands)

    Mugasa, Claire M.; Adams, Emily R.; Boer, Kimberly R.; Dyserinck, Heleen C.; Büscher, Philippe; Schallig, Henk D. H. F.; Leeflang, Mariska M. G.

    2012-01-01

    Background: A range of molecular amplification techniques have been developed for the diagnosis of Human African Trypanosomiasis (HAT); however, careful evaluation of these tests must precede implementation to ensure their high clinical accuracy. Here, we investigated the diagnostic accuracy of

  15. Urinary tract infections in general practice patients: diagnostic tests versus bacteriological culture.

    NARCIS (Netherlands)

    Nys, S.; Merode, T. van; Bartelds, A.I.M.; Stobberingh, E.E.

    2006-01-01

    Objectives: Urinary tract infections (UTIs) are common bacterial infections encountered in general practice. For the optimal treatment the general practitioner (GP) should rely on the results of diagnostic tests and recent antimicrobial susceptibility of uropathogens. Patients and methods: In total

  16. Remote visual testing (RVT) for the diagnostic inspection of feedwater heaters

    International Nuclear Information System (INIS)

    Nugent, M.J.; Pellegrino, B.A.

    1991-01-01

    In this paper the benefits and limitations of Non-Destructive Testing (NDT) on feedwater heaters will be briefly reviewed. All Remote Visual Testing (RVT) devices including borescopes, fiberscopes, videoborescopes and Closed Circuit Television (CCTV) cameras will be discussed along with currently accepted formats for documentation. The benefits of a comprehensive in-place inspection involving Remote Visual Testing will be discussed in relationship to its diagnostic capabilities. The results of eight post-service heater inspections will be discussed along with the root cause of failure of seven unique failure mechanisms. These inspections, including FWH access, RVT tool and data analysis, will be detailed

  17. Molecular diagnostics for hereditary hearing loss in children.

    Science.gov (United States)

    Sommen, Manou; Wuyts, Wim; Van Camp, Guy

    2017-08-01

    Hearing loss (HL) is the most common birth defect in industrialized countries with far-reaching social, psychological and cognitive implications. It is an extremely heterogeneous disease, complicating molecular testing. The introduction of next-generation sequencing (NGS) has resulted in great progress in diagnostics allowing to study all known HL genes in a single assay. The diagnostic yield is currently still limited, but has the potential to increase substantially. Areas covered: In this review the utility of NGS and the problems for comprehensive molecular testing for HL are evaluated and discussed. Expert commentary: Different publications have proven the appropriateness of NGS for molecular testing of heterogeneous diseases such as HL. However, several problems still exist, such as pseudogenic background of some genes and problematic copy number variant analysis on targeted NGS data. Another main challenge for the future will be the establishment of population specific mutation-spectra to achieve accurate personalized comprehensive molecular testing for HL.

  18. Diagnostic validation of three test methods for detection of cyprinid herpesvirus 3 (CyHV-3).

    Science.gov (United States)

    Clouthier, Sharon C; McClure, Carol; Schroeder, Tamara; Desai, Megan; Hawley, Laura; Khatkar, Sunita; Lindsay, Melissa; Lowe, Geoff; Richard, Jon; Anderson, Eric D

    2017-03-06

    Cyprinid herpesvirus 3 (CyHV-3) is the aetiological agent of koi herpesvirus disease in koi and common carp. The disease is notifiable to the World Organisation for Animal Health. Three tests-quantitative polymerase chain reaction (qPCR), conventional PCR (cPCR) and virus isolation by cell culture (VI)-were validated to assess their fitness as diagnostic tools for detection of CyHV-3. Test performance metrics of diagnostic accuracy were sensitivity (DSe) and specificity (DSp). Repeatability and reproducibility were measured to assess diagnostic precision. Estimates of test accuracy, in the absence of a gold standard reference test, were generated using latent class models. Test samples originated from wild common carp naturally exposed to CyHV-3 or domesticated koi either virus free or experimentally infected with the virus. Three laboratories in Canada participated in the precision study. Moderate to high repeatability (81 to 99%) and reproducibility (72 to 97%) were observed for the qPCR and cPCR tests. The lack of agreement observed between some of the PCR test pair results was attributed to cross-contamination of samples with CyHV-3 nucleic acid. Accuracy estimates for the PCR tests were 99% for DSe and 93% for DSp. Poor precision was observed for the VI test (4 to 95%). Accuracy estimates for VI/qPCR were 90% for DSe and 88% for DSp. Collectively, the results show that the CyHV-3 qPCR test is a suitable tool for surveillance, presumptive diagnosis and certification of individuals or populations as CyHV-3 free.

  19. Decreased CSF transferrin in sCJD: a potential pre-mortem diagnostic test for prion disorders.

    Directory of Open Access Journals (Sweden)

    Ajay Singh

    2011-03-01

    Full Text Available Sporadic Creutzfeldt-Jakob-disease (sCJD is a fatal neurodegenerative condition that escapes detection until autopsy. Recently, brain iron dyshomeostasis accompanied by increased transferrin (Tf was reported in sCJD cases. The consequence of this abnormality on cerebrospinal-fluid (CSF levels of Tf is uncertain. We evaluated the accuracy of CSF Tf, a 'new' biomarker, as a pre-mortem diagnostic test for sCJD when used alone or in combination with the 'current' biomarker total-tau (T-tau. Levels of total-Tf (T-Tf, isoforms of Tf (Tf-1 and Tf-β2, and iron saturation of Tf were quantified in CSF collected 0.3-36 months before death (duration from 99 autopsy confirmed sCJD (CJD+ and 75 confirmed cases of dementia of non-CJD origin (CJD-. Diagnostic accuracy was estimated by non-parametric tests, logistic regression, and receiver operating characteristic (ROC analysis. Area under the ROC curve (AUC, sensitivity, specificity, positive and negative predictive values (PV, and likelihood ratios (LR of each biomarker and biomarker combination were calculated. We report that relative to CJD-, CJD+ cases had lower median CSF T-Tf (125,7093 vs. 217,7893 and higher T-tau (11530 vs. 1266 values. AUC was 0.90 (95% confidence interval (CI, 0.85-0.94 for T-Tf, and 0.93 (95% CI, 0.89-0.97 for T-Tf combined with T-tau. With cut-offs defined to achieve a sensitivity of ∼85%, T-Tf identified CJD+ cases with a specificity of 71.6% (95% CI, 59.1-81.7, positive LR of 3.0 (95% CI, 2.1-4.5, negative LR of 0.2 (95% CI, 0.1-0.3, and accuracy of 80.1%. The effect of patient age and duration was insignificant. T-Tf combined with T-tau identified CJD+ with improved specificity of 87.5% (95%CI, 76.3-94.1, positive LR of 6.8 (95% CI, 3.5-13.1, negative LR of 0.2 (95% CI, 0.1-0.3, positive-PV of 91.0%, negative-PV of 80.0%, and accuracy of 86.2%. Thus, CSF T-Tf, a new biomarker, when combined with the current biomarker T-tau, is a reliable pre-mortem diagnostic test for sCJD.

  20. Diagnostic tests’ decision-making rules based upon analysis of ROC-curves

    Directory of Open Access Journals (Sweden)

    Л. В. Батюк

    2015-10-01

    Full Text Available In this paper we propose the model which substantiates diagnostics decision making based on the analysis of Receiver Operating Characteristic curves (ROC-curves and predicts optimal values of diagnostic indicators of biomedical information. To assess the quality of the test result prediction the standard criteria of the sensitivity and specificity of the model were used. Values of these criteria were calculated for the cases when the sensitivity of the test was greater than specificity by several times, when the number of correct diagnoses was maximal, when the sensitivity of the test was equal to its specificity and the sensitivity of the test was several times greater than the specificity of the test. To assess the significance of the factor characteristics and to compare the prognostic characteristics of models we used mathematical modeling and plotting the ROC-curves. The optimal value of the diagnostic indicator was found to be achieved when the sensitivity of the test is equal to its specificity. The model was adapted to solve the case when the sensitivity of the test is greater than specificity of the test.

  1. Development and testing of a diagnostic system for intelligen distributed control at EBR-2

    International Nuclear Information System (INIS)

    Edwards, R.M.; Ruhl, D.W.; Klevans, E.H.; Robinson, G.E.

    1990-01-01

    A diagnostic system is under development for demonstration of Intelligent Distributed Control at the Experimental Breeder Reactor (EBR--II). In the first phase of the project a diagnostic system is being developed for the EBR-II steam plant based on the DISYS expert systems approach. Current testing uses recorded plant data and data from simulated plant faults. The dynamical simulation of the EBR-II steam plant uses the Babcock and Wilcox (B ampersand W) Modular Modeling System (MMS). At EBR-II the diagnostic system operates in the UNIX workstation and receives live plant data from the plant Data Acquisition System (DAS). Future work will seek implementation of the steam plant diagnostic in a distributed manner using UNIX based computers and Bailey microprocessor-based control system. 10 refs., 6 figs

  2. The Relationship between Learning Style, Test Anxiety and Academic Achievement

    Science.gov (United States)

    Yazici, Kubilay

    2017-01-01

    This study aimed to investigate the relationship between social studies pre-service teachers' (SSPTs) learning style, test anxiety and academic achievement. A total of 315 SSPTs participated in the study. Data were collected using Turkish versions of Grasha-Reichmann learning style scale (GRLSS) and test anxiety scale (TAS) by Spielberger.…

  3. 9 CFR 130.17 - User fees for other veterinary diagnostic laboratory tests performed at NVSL (excluding FADDL) or...

    Science.gov (United States)

    2010-01-01

    ... 9 Animals and Animal Products 1 2010-01-01 2010-01-01 false User fees for other veterinary... FEES USER FEES § 130.17 User fees for other veterinary diagnostic laboratory tests performed at NVSL (excluding FADDL) or at authorized sites. (a) User fees for veterinary diagnostics tests performed at the...

  4. 9 CFR 130.16 - User fees for veterinary diagnostic serology tests performed at NVSL (excluding FADDL) or at...

    Science.gov (United States)

    2010-01-01

    ... 9 Animals and Animal Products 1 2010-01-01 2010-01-01 false User fees for veterinary diagnostic serology tests performed at NVSL (excluding FADDL) or at authorized sites. 130.16 Section 130.16 Animals... USER FEES § 130.16 User fees for veterinary diagnostic serology tests performed at NVSL (excluding...

  5. A Review of Neuropathic Pain: From Diagnostic Tests to Mechanisms

    OpenAIRE

    Truini, Andrea

    2017-01-01

    Neuropathic pain develops when the somatosensory nervous system is affected by a lesion or disease. Diagnostic tests aimed at assessing somatosensory afferent pathway damage are therefore useful for diagnosing neuropathic pain. Neuropathic pain manifests with a range of different symptoms such as ongoing burning pain, squeezing or pressure pain, paroxysmal electric shock-like sensations, stabbing pain, or mechanical dynamic allodynia. The various types of neuropathic pain are associated with ...

  6. Diagnostic Accuracy of Quantitative Sensory Testing to Discriminate Inflammatory Toothache and Intraoral Neuropathic Pain.

    Science.gov (United States)

    Porporatti, André Luís; Costa, Yuri Martins; Stuginski-Barbosa, Juliana; Bonjardim, Leonardo Rigoldi; Duarte, Marco Antônio Hungaro; Conti, Paulo César Rodrigues

    2015-10-01

    A differential diagnosis between inflammatory toothache (IT) and intraoral neuropathic pain is challenging. The aim of this diagnostic study was to quantify somatosensory function of subjects with IT (acute pulpitis) and atypical odontalgia (AO, intraoral neuropathic pain) and healthy volunteers and to quantify how accurately quantitative sensory testing (QST) discriminates an IT or AO diagnosis. The sample consisted of 60 subjects equally divided (n = 20) into 3 groups: (1) IT, (2) AO, and (3) control. A sequence of 4 QST methods was performed over the dentoalveolar mucosa in the apical maxillar or mandibular area: mechanical detection threshold, pain detection threshold (PDT), dynamic mechanical allodynia, and temporal summation. One-way analysis of variance, Tukey post hoc analyses, and z score transformation were applied to the data. In addition, the receiver operating characteristic curve analysis, diagnostic accuracy, sensitivity, specificity, likelihood ratios, and diagnostic odds ratio of the QST methods were calculated (α = 5%). Somatosensory abnormalities were found for the AO group, which is consistent with a low detection threshold to touch and pain and the presence of mechanical allodynia. For the IT group, no somatosensory abnormality was observed when compared with the control group. The most accurate QST to discriminate the diagnostic differences between IT and healthy individuals is the PDT. The diagnostic differences between AO and healthy individuals and between IT and AO are best discriminated with the mechanical detection threshold, PDT, and dynamic mechanical allodynia. The proposed QST methods may aid in the differential diagnosis between IT and AO with strong accuracy and may be used as complementary diagnostic tests. Copyright © 2015 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  7. A diagnostic model incorporating P50 sensory gating and neuropsychological tests for schizophrenia.

    Directory of Open Access Journals (Sweden)

    Jia-Chi Shan

    Full Text Available OBJECTIVES: Endophenotypes in schizophrenia research is a contemporary approach to studying this heterogeneous mental illness, and several candidate neurophysiological markers (e.g. P50 sensory gating and neuropsychological tests (e.g. Continuous Performance Test (CPT and Wisconsin Card Sorting Test (WCST have been proposed. However, the clinical utility of a single marker appears to be limited. In the present study, we aimed to construct a diagnostic model incorporating P50 sensory gating with other neuropsychological tests in order to improve the clinical utility. METHODS: We recruited clinically stable outpatients meeting DSM-IV criteria of schizophrenia and age- and gender-matched healthy controls. Participants underwent P50 sensory gating experimental sessions and batteries of neuropsychological tests, including CPT, WCST and Wechsler Adult Intelligence Scale Third Edition (WAIS-III. RESULTS: A total of 106 schizophrenia patients and 74 healthy controls were enrolled. Compared with healthy controls, the patient group had significantly a larger S2 amplitude, and thus poorer P50 gating ratio (gating ratio = S2/S1. In addition, schizophrenia patients had a poorer performance on neuropsychological tests. We then developed a diagnostic model by using multivariable logistic regression analysis to differentiate patients from healthy controls. The final model included the following covariates: abnormal P50 gating (defined as P50 gating ratio >0.4, three subscales derived from the WAIS-III (Arithmetic, Block Design, and Performance IQ, sensitivity index from CPT and smoking status. This model had an adequate accuracy (concordant percentage = 90.4%; c-statistic = 0.904; Hosmer-Lemeshow Goodness-of-Fit Test, p = 0.64>0.05. CONCLUSION: To the best of our knowledge, this is the largest study to date using P50 sensory gating in subjects of Chinese ethnicity and the first to use P50 sensory gating along with other neuropsychological tests

  8. Diagnostic test accuracy of nutritional tools used to identify undernutrition in patients with colorectal cancer: a systematic review.

    Science.gov (United States)

    Håkonsen, Sasja Jul; Pedersen, Preben Ulrich; Bath-Hextall, Fiona; Kirkpatrick, Pamela

    2015-05-15

    Effective nutritional screening, nutritional care planning and nutritional support are essential in all settings, and there is no doubt that a health service seeking to increase safety and clinical effectiveness must take nutritional care seriously. Screening and early detection of malnutrition is crucial in identifying patients at nutritional risk. There is a high prevalence of malnutrition in hospitalized patients undergoing treatment for colorectal cancer. To synthesize the best available evidence regarding the diagnostic test accuracy of nutritional tools (sensitivity and specificity) used to identify malnutrition (specifically undernutrition) in patients with colorectal cancer (such as the Malnutrition Screening Tool and Nutritional Risk Index) compared to reference tests (such as the Subjective Global Assessment or Patient Generated Subjective Global Assessment). Patients with colorectal cancer requiring either (or all) surgery, chemotherapy and/or radiotherapy in secondary care. Focus of the review: The diagnostic test accuracy of validated assessment tools/instruments (such as the Malnutrition Screening Tool and Nutritional Risk Index) in the diagnosis of malnutrition (specifically under-nutrition) in patients with colorectal cancer, relative to reference tests (Subjective Global Assessment or Patient Generated Subjective Global Assessment). Types of studies: Diagnostic test accuracy studies regardless of study design. Studies published in English, German, Danish, Swedish and Norwegian were considered for inclusion in this review. Databases were searched from their inception to April 2014. Methodological quality was determined using the Quality Assessment of Diagnostic Accuracy Studies checklist. Data was collected using the data extraction form: the Standards for Reporting Studies of Diagnostic Accuracy checklist for the reporting of studies of diagnostic accuracy. The accuracy of diagnostic tests is presented in terms of sensitivity, specificity, positive

  9. The meaning of diagnostic test results: A spreadsheet for swift data analysis

    International Nuclear Information System (INIS)

    MacEneaney, Peter M.; Malone, Dermot E.

    2000-01-01

    AIMS: To design a spreadsheet program to: (a) analyse rapidly diagnostic test result data produced in local research or reported in the literature; (b) correct reported predictive values for disease prevalence in any population; (c) estimate the post-test probability of disease in individual patients. MATERIALS AND METHODS: Microsoft Excel TM was used. Section A: a contingency (2 x 2) table was incorporated into the spreadsheet. Formulae for standard calculations [sample size, disease prevalence, sensitivity and specificity with 95% confidence intervals, predictive values and likelihood ratios (LRs)] were linked to this table. The results change automatically when the data in the true or false negative and positive cells are changed. Section B: this estimates predictive values in any population, compensating for altered disease prevalence. Sections C-F: Bayes' theorem was incorporated to generate individual post-test probabilities. The spreadsheet generates 95% confidence intervals, LRs and a table and graph of conditional probabilities once the sensitivity and specificity of the test are entered. The latter shows the expected post-test probability of disease for any pre-test probability when a test of known sensitivity and specificity is positive or negative. RESULTS: This spreadsheet can be used on desktop and palmtop computers. The MS Excel TM version can be downloaded via the Internet from the URL ftp://radiography.com/pub/Rad-data99.xls CONCLUSION: A spreadsheet is useful for contingency table data analysis and assessment of the clinical meaning of diagnostic test results. MacEneaney, P.M., Malone, D.E. (2000)

  10. Reactor protection system with automatic self-testing and diagnostic

    International Nuclear Information System (INIS)

    Gaubatz, D.C.

    1996-01-01

    A reactor protection system is disclosed having four divisions, with quad redundant sensors for each scram parameter providing input to four independent microprocessor-based electronic chassis. Each electronic chassis acquires the scram parameter data from its own sensor, digitizes the information, and then transmits the sensor reading to the other three electronic chassis via optical fibers. To increase system availability and reduce false scrams, the reactor protection system employs two levels of voting on a need for reactor scram. The electronic chassis perform software divisional data processing, vote 2/3 with spare based upon information from all four sensors, and send the divisional scram signals to the hardware logic panel, which performs a 2/4 division vote on whether or not to initiate a reactor scram. Each chassis makes a divisional scram decision based on data from all sensors. Automatic detection and discrimination against failed sensors allows the reactor protection system to automatically enter a known state when sensor failures occur. Cross communication of sensor readings allows comparison of four theoretically ''identical'' values. This permits identification of sensor errors such as drift or malfunction. A diagnostic request for service is issued for errant sensor data. Automated self test and diagnostic monitoring, sensor input through output relay logic, virtually eliminate the need for manual surveillance testing. This provides an ability for each division to cross-check all divisions and to sense failures of the hardware logic. 16 figs

  11. Safety and Yield of Diagnostic ERCP in Liver Transplant Patients with Abnormal Liver Function Tests

    Directory of Open Access Journals (Sweden)

    Jayapal Ramesh

    2014-01-01

    Full Text Available Background. Abnormal liver enzymes postorthotopic liver transplant (OLT may indicate significant biliary pathology or organ rejection. There is very little known in the literature regarding the current role of diagnostic ERCP in this scenario. Aim. To review the utility of diagnostic ERCP in patients presenting with abnormal liver function tests in the setting of OLT. Methods. A retrospective review of diagnostic ERCPs in patients with OLT from 2002 to 2013 from a prospectively maintained, IRB approved database. Results. Of the 474 ERCPs performed in OLT patients, 210 (44.3%; 95% CI 39.8–48.8 were performed for abnormal liver function tests during the study period. Majority of patients were Caucasian (83.8%, male (62.4% with median age of 55 years (IQR 48–62 years. Biliary cannulation was successful in 99.6% of cases and findings included stricture in 45 (21.4 %; biliary stones/sludge in 23 (11%; biliary dilation alone in 31 (14.8%; and normal in 91 (43.3%. Three (1.4% patients developed mild, self-limiting pancreatitis; one patient (0.5% developed cholangitis and two (1% had postsphincterotomy bleeding. Multivariate analyses showed significant association between dilated ducts on imaging with a therapeutic outcome. Conclusion. Diagnostic ERCP in OLT patients presenting with liver function test abnormalities is safe and frequently therapeutic.

  12. HIV misdiagnosis in sub-Saharan Africa: performance of diagnostic algorithms at six testing sites

    Science.gov (United States)

    Kosack, Cara S.; Shanks, Leslie; Beelaert, Greet; Benson, Tumwesigye; Savane, Aboubacar; Ng’ang’a, Anne; Andre, Bita; Zahinda, Jean-Paul BN; Fransen, Katrien; Page, Anne-Laure

    2017-01-01

    Abstract Introduction: We evaluated the diagnostic accuracy of HIV testing algorithms at six programmes in five sub-Saharan African countries. Methods: In this prospective multisite diagnostic evaluation study (Conakry, Guinea; Kitgum, Uganda; Arua, Uganda; Homa Bay, Kenya; Doula, Cameroun and Baraka, Democratic Republic of Congo), samples from clients (greater than equal to five years of age) testing for HIV were collected and compared to a state-of-the-art algorithm from the AIDS reference laboratory at the Institute of Tropical Medicine, Belgium. The reference algorithm consisted of an enzyme-linked immuno-sorbent assay, a line-immunoassay, a single antigen-enzyme immunoassay and a DNA polymerase chain reaction test. Results: Between August 2011 and January 2015, over 14,000 clients were tested for HIV at 6 HIV counselling and testing sites. Of those, 2786 (median age: 30; 38.1% males) were included in the study. Sensitivity of the testing algorithms ranged from 89.5% in Arua to 100% in Douala and Conakry, while specificity ranged from 98.3% in Doula to 100% in Conakry. Overall, 24 (0.9%) clients, and as many as 8 per site (1.7%), were misdiagnosed, with 16 false-positive and 8 false-negative results. Six false-negative specimens were retested with the on-site algorithm on the same sample and were found to be positive. Conversely, 13 false-positive specimens were retested: 8 remained false-positive with the on-site algorithm. Conclusions: The performance of algorithms at several sites failed to meet expectations and thresholds set by the World Health Organization, with unacceptably high rates of false results. Alongside the careful selection of rapid diagnostic tests and the validation of algorithms, strictly observing correct procedures can reduce the risk of false results. In the meantime, to identify false-positive diagnoses at initial testing, patients should be retested upon initiating antiretroviral therapy. PMID:28691437

  13. Spatial resolution test of a beam diagnostic system for DESIREE

    Science.gov (United States)

    Das, Susanta; Kallberg, A.

    2010-11-01

    A diagnostic system based on the observation of low energy ( ˜ 10 eV) secondary electrons (SE) produced by a beam, striking a metallic foil has been built to monitor and to cover the wide range of beam intensities and energies for Double ElectroStatic Ion Ring ExpEriment [1,2].The system consists of a Faraday cup to measure the beam current, a collimator with circular apertures of different diameters to measure the spatial resolution of the system, a beam profile monitoring system (BPMS), and a control unit. The BPMS, in turn, consists of an aluminim (Al) foil, a grid placed in front of the Al foil to accelerate the SE, position sensitive MCP, fluorescent screen, and a CCD camera to capture the images. The collimator contains a set of circular holes of different diameters and separations (d) between them. The collimator cuts out from the beam areas equal to the holes with separation d mm between the beams centers and creates well separated (distinguishable) narrow beams of approximately same intensity close to each other. A 10 keV proton beam was used. The spatial resolution of the system was tested for different Al plate and MCP voltages and resolution of better than 2 mm was achieved. Ref.: 1. K. Kruglov {et al}., NIM A 441 (2000) 595; 701 (2002) 193c, 2. MSL and Atomic Physics, Stockholm Univ.(www.msl.se, http://www.atom.physto.se/Cederquist/desiree/web/hc.html).

  14. Bias in logistic regression due to imperfect diagnostic test results and practical correction approaches.

    Science.gov (United States)

    Valle, Denis; Lima, Joanna M Tucker; Millar, Justin; Amratia, Punam; Haque, Ubydul

    2015-11-04

    Logistic regression is a statistical model widely used in cross-sectional and cohort studies to identify and quantify the effects of potential disease risk factors. However, the impact of imperfect tests on adjusted odds ratios (and thus on the identification of risk factors) is under-appreciated. The purpose of this article is to draw attention to the problem associated with modelling imperfect diagnostic tests, and propose simple Bayesian models to adequately address this issue. A systematic literature review was conducted to determine the proportion of malaria studies that appropriately accounted for false-negatives/false-positives in a logistic regression setting. Inference from the standard logistic regression was also compared with that from three proposed Bayesian models using simulations and malaria data from the western Brazilian Amazon. A systematic literature review suggests that malaria epidemiologists are largely unaware of the problem of using logistic regression to model imperfect diagnostic test results. Simulation results reveal that statistical inference can be substantially improved when using the proposed Bayesian models versus the standard logistic regression. Finally, analysis of original malaria data with one of the proposed Bayesian models reveals that microscopy sensitivity is strongly influenced by how long people have lived in the study region, and an important risk factor (i.e., participation in forest extractivism) is identified that would have been missed by standard logistic regression. Given the numerous diagnostic methods employed by malaria researchers and the ubiquitous use of logistic regression to model the results of these diagnostic tests, this paper provides critical guidelines to improve data analysis practice in the presence of misclassification error. Easy-to-use code that can be readily adapted to WinBUGS is provided, enabling straightforward implementation of the proposed Bayesian models.

  15. The Value of Naproxen Test as a Diagnostic Method to Differentiate Cause of Fever

    Directory of Open Access Journals (Sweden)

    Omer Coskun

    2012-12-01

    Full Text Available Objective: Fever of whatever etiology still remains a perplexing problem to both clinicians and investigators. Increasingly, its role in connective tissue diseases, malignancies and other inflammatory disorders is slowly supplanting the exclusivity of the symptom to just infectious conditions. This study aims to determine the sensitivity of the naproxen test and the diagnostic value in patients with a prolonged febrile illness. Methods: We evaluated twenty patients had been administered the naproxen test. Fever lysis after or within the time frame of drug administration was interpreted as a infectious or an infectious condition. Results: Infectious diseases etiology was detected at 15 patients. 12 and 3 of them responded to naproxen test at the first and second days respectively. Two of non-infectious etiology patients remained unanswered. Conclusion: This study clearly showed that the naproxen test cannot be relied upon to guide diagnostic decision making in patients with fever unknown origin. [TAF Prev Med Bull 2012; 11(6.000: 779-782

  16. Diagnostic evaluation of rapid tests for scrub typhus in the Indian population is needed.

    Science.gov (United States)

    Shivalli, Siddharudha

    2016-05-12

    Owing to frequent outbreaks witnessed in different parts of the country in the recent past, scrub typhus is being described as a re-emerging infectious disease in India. Differentiating scrub typhus from other endemic diseases like malaria, leptospirosis, dengue fever, typhoid, etc. is difficult due to overlapping clinical features and a lower positivity for eschars in Asian populations. Hence, the diagnosis heavily relies on laboratory tests. Costs and the need of technical expertise limit the wide use of indirect immunoperoxidase or immunofluorescence assays, ELISA and PCR. The Weil-Felix test is the most commonly used and least expensive serological test, but lacks both sensitivity and specificity. Hence, the diagnosis of scrub typhus is often delayed or overlooked. With due consideration of the cost, rapidity, single test result and simplicity of interpretation, rapid diagnostic tests have come into vogue. However, evaluation of rapid diagnostic tests for scrub typhus in the Indian population is needed to justify or discourage their use. Research studies are needed to find the most suitable test in terms of the rapidity of the result, simplicity of the procedure, ease of interpretation and cost to be used in the Indian populace.

  17. 9 CFR 130.15 - User fees for veterinary diagnostic isolation and identification tests performed at NVSL...

    Science.gov (United States)

    2010-01-01

    ... 9 Animals and Animal Products 1 2010-01-01 2010-01-01 false User fees for veterinary diagnostic isolation and identification tests performed at NVSL (excluding FADDL) or other authorized site. 130.15... AGRICULTURE USER FEES USER FEES § 130.15 User fees for veterinary diagnostic isolation and identification...

  18. Utilisation du test GeneXpert pour le diagnostic de la tuberculose au ...

    African Journals Online (AJOL)

    Utilisation du test GeneXpert pour le diagnostic de la tuberculose au service des maladies infectieuses du CHNU de Fann. Sylvie Audrey Diop, Aminata Massaly, Daye Ka, Noel Magloire Manga, Louise Fortes-Déguénonvo, Cheikh Tidiane Ndour, Viviane Marie Pierre Cisse, Moussa Seydi ...

  19. Mathematics Diagnostic Testing in Engineering: An International Comparison between Ireland and Portugal

    Science.gov (United States)

    Carr, M.; Fidalgo, C.; Bigotte de Almeida, M. E.; Branco, J. R.; Santos, V.; Murphy, E.; Ní Fhloinn, E.

    2015-01-01

    Concern has been expressed throughout Europe about the significant deficiencies in the basic mathematical skills of many engineering undergraduates. Mathematics diagnostic tests in the UK, Ireland and Portugal have shown these shortcomings, which provide a challenge to those striving to introduce more innovative educational practices into…

  20. Test Format and the Variation of Gender Achievement Gaps within the United States

    Science.gov (United States)

    Reardon, Sean; Fahle, Erin; Kalogrides, Demetra; Podolsky, Anne; Zarate, Rosalia

    2016-01-01

    Prior research demonstrates the existence of gender achievement gaps and the variation in the magnitude of these gaps across states. This paper characterizes the extent to which the variation of gender achievement gaps on standardized tests across the United States can be explained by differing state accountability test formats. A comprehensive…

  1. Test Review: D. Wechsler "Wechsler Individual Achievement Test-Third Edition." San Antonio, TX--NCS Pearson, 2009

    Science.gov (United States)

    McCrimmon, Adam W.; Climie, Emma A.

    2011-01-01

    This article reviews the "Wechsler Individual Achievement Test-Third Edition" (WIAT-III), a newly updated individual measure of academic achievement for students in Pre-Kindergarten through Grade 12 (age 4 years, 0 months to 19 years, 11 months). Suitable for use in educational, clinical, and research settings, the stated purposes of the WIAT-III…

  2. Performance and Pain Tolerability of Current Diagnostic Allergy Skin Prick Test Devices.

    Science.gov (United States)

    Tversky, Jody R; Chelladurai, Yohalakshmi; McGready, John; Hamilton, Robert G

    2015-01-01

    Allergen skin prick testing remains an essential tool for diagnosing atopic disease and guiding treatment. Sensitivity needs to be defined for newly introduced devices. Our aim was to compare the performance of 10 current allergy skin prick test devices. Single- and multiheaded skin test devices (n = 10) were applied by a single operator in a prospective randomized manner. Histamine (1 and 6 mg/mL) and control diluent were introduced at 6 randomized locations onto the upper and lower arms of healthy subjects. Wheal and flare reactions were measured independently by 2 masked technicians. Twenty-four subjects provided consent, and 768 skin tests were placed. Mean wheal diameter among devices differed from 3.0 mm (ComforTen; Hollister-Stier, Spokane, Wash) to 6.8 mm (UniTest PC; Lincoln Diagnostics, Decatur, Ill) using 1 mg/mL histamine (P Diagnostics, Decatur, Ill; and Sharp-Test; Panatrex, Placentia, Calif) using 6 mg/mL histamine (P pain score of less than 4 on a 10-point visual analog scale. Pain scores were higher among women, but this did not reach statistical significance. The Multi-Test PC and the UniTest PC had the lowest pain scores compared with the other devices. All 10 skin prick test devices displayed good analytical sensitivity and specificity; however, 3 mm cannot arbitrarily be used as a positive threshold. The use of histamine at 1 mg/mL is unacceptable for certain devices but may be preferable for the most sensitive devices. On average, there was no pain score difference between multiheaded and single-head devices. Copyright © 2015 American Academy of Allergy, Asthma & Immunology. Published by Elsevier Inc. All rights reserved.

  3. The Hug-up Test: A New, Sensitive Diagnostic Test for Supraspinatus Tears

    Directory of Open Access Journals (Sweden)

    Yu-Lei Liu

    2016-01-01

    Full Text Available Background: The supraspinatus tendon is the most commonly affected tendon in rotator cuff tears. Early detection of a supraspinatus tear using an accurate physical examination is, therefore, important. However, the currently used physical tests for detecting supraspinatus tears are poor diagnostic indicators and involve a wide range of sensitivity and specificity values. Therefore, the aim of this study was to establish a new physical test for the diagnosis of supraspinatus tears and evaluate its accuracy in comparison with conventional tests. Methods: Between November 2012 and January 2014, 200 consecutive patients undergoing shoulder arthroscopy were prospectively evaluated preoperatively. The hug-up test, empty can (EC test, full can (FC test, Neer impingement sign, and Hawkins-Kennedy impingement sign were used and compared statistically for their accuracy in terms of supraspinatus tears, with arthroscopic findings as the gold standard. Muscle strength was precisely quantified using an electronic digital tensiometer. Results: The prevalence of supraspinatus tears was 76.5%. The hug-up test demonstrated the highest sensitivity (94.1%, with a low negative likelihood ratio (NLR, 0.08 and comparable specificity (76.6% compared with the other four tests. The area under the receiver operating characteristic curve for the hug-up test was 0.854, with no statistical difference compared with the EC test (z = 1.438, P = 0.075 or the FC test (z = 1.498, P = 0.067. The hug-up test showed no statistical difference in terms of detecting different tear patterns according to the position (χ2 = 0.578, P = 0.898 and size (Fisher′s exact test, P > 0.999 compared with the arthroscopic examination. The interobserver reproducibility of the hug-up test was high, with a kappa coefficient of 0.823. Conclusions: The hug-up test can accurately detect supraspinatus tears with a high sensitivity, comparable specificity, and low NLR compared with the conventional

  4. Rapid antigen detection test for respiratory syncytial virus diagnosis as a diagnostic tool

    Directory of Open Access Journals (Sweden)

    Flávio da Silva Mesquita

    2017-05-01

    Conclusions: This study demonstrated that the QuickVue® RSV Test Kit can be effective in early detection of Respiratory syncytial virus in nasopharyngeal aspirate and is reliable for use as a diagnostic tool in pediatrics.

  5. The cobas® 6800/8800 System: a new era of automation in molecular diagnostics.

    Science.gov (United States)

    Cobb, Bryan; Simon, Christian O; Stramer, Susan L; Body, Barbara; Mitchell, P Shawn; Reisch, Natasa; Stevens, Wendy; Carmona, Sergio; Katz, Louis; Will, Stephen; Liesenfeld, Oliver

    2017-02-01

    Molecular diagnostics is a key component of laboratory medicine. Here, the authors review key triggers of ever-increasing automation in nucleic acid amplification testing (NAAT) with a focus on specific automated Polymerase Chain Reaction (PCR) testing and platforms such as the recently launched cobas® 6800 and cobas® 8800 Systems. The benefits of such automation for different stakeholders including patients, clinicians, laboratory personnel, hospital administrators, payers, and manufacturers are described. Areas Covered: The authors describe how molecular diagnostics has achieved total laboratory automation over time, rivaling clinical chemistry to significantly improve testing efficiency. Finally, the authors discuss how advances in automation decrease the development time for new tests enabling clinicians to more readily provide test results. Expert Commentary: The advancements described enable complete diagnostic solutions whereby specific test results can be combined with relevant patient data sets to allow healthcare providers to deliver comprehensive clinical recommendations in multiple fields ranging from infectious disease to outbreak management and blood safety solutions.

  6. Diagnostic validity of physical examination tests for common knee disorders: An overview of systematic reviews and meta-analysis.

    Science.gov (United States)

    Décary, Simon; Ouellet, Philippe; Vendittoli, Pascal-André; Roy, Jean-Sébastien; Desmeules, François

    2017-01-01

    More evidence on diagnostic validity of physical examination tests for knee disorders is needed to lower frequently used and costly imaging tests. To conduct a systematic review of systematic reviews (SR) and meta-analyses (MA) evaluating the diagnostic validity of physical examination tests for knee disorders. A structured literature search was conducted in five databases until January 2016. Methodological quality was assessed using the AMSTAR. Seventeen reviews were included with mean AMSTAR score of 5.5 ± 2.3. Based on six SR, only the Lachman test for ACL injuries is diagnostically valid when individually performed (Likelihood ratio (LR+):10.2, LR-:0.2). Based on two SR, the Ottawa Knee Rule is a valid screening tool for knee fractures (LR-:0.05). Based on one SR, the EULAR criteria had a post-test probability of 99% for the diagnosis of knee osteoarthritis. Based on two SR, a complete physical examination performed by a trained health provider was found to be diagnostically valid for ACL, PCL and meniscal injuries as well as for cartilage lesions. When individually performed, common physical tests are rarely able to rule in or rule out a specific knee disorder, except the Lachman for ACL injuries. There is low-quality evidence concerning the validity of combining history elements and physical tests. Copyright © 2016 Elsevier Ltd. All rights reserved.

  7. Self Diagnostic Accelerometer Testing on the C-17 Aircraft

    Science.gov (United States)

    Tokars, Roger P.; Lekki, John D.

    2013-01-01

    The self diagnostic accelerometer (SDA) developed by the NASA Glenn Research Center was tested for the first time in an aircraft engine environment as part of the Vehicle Integrated Propulsion Research (VIPR) program. The VIPR program includes testing multiple critical flight sensor technologies. One such sensor, the accelerometer, measures vibrations to detect faults in the engine. In order to rely upon the accelerometer, the health of the accelerometer must be ensured. The SDA is a sensor system designed to actively determine the accelerometer structural health and attachment condition, in addition to vibration measurements. The SDA uses a signal conditioning unit that sends an electrical chirp to the accelerometer and recognizes changes in the response due to changes in the accelerometer health and attachment condition. To demonstrate the SDAs flight worthiness and robustness, multiple SDAs were mounted and tested on a C-17 aircraft engine. The engine test conditions varied from engine off, to idle, to maximum power. The SDA attachment conditions were varied from fully tight to loose. The newly developed SDA health algorithm described herein uses cross correlation pattern recognition to discriminate a healthy from a faulty SDA. The VIPR test results demonstrate for the first.

  8. Math Self-Concept, Grades, and Achievement Test Scores: Long-Term Reciprocal Effects across Five Waves and Three Achievement Tracks

    Science.gov (United States)

    Arens, A. Katrin; Marsh, Herbert W.; Pekrun, Reinhard; Lichtenfeld, Stephanie; Murayama, Kou; vom Hofe, Rudolf

    2017-01-01

    This study examines reciprocal effects between self-concept and achievement by considering a long time span covering grades 5 through 9. Extending previous research on the reciprocal effects model (REM), this study tests (1) the assumption of developmental equilibrium as time-invariant cross-lagged paths from self-concept to achievement and from…

  9. Locus of control, test anxiety, academic procrastination, and achievement among college students.

    Science.gov (United States)

    Carden, Randy; Bryant, Courtney; Moss, Rebekah

    2004-10-01

    114 undergraduates completed the Internal-External Locus of Control scale, the Procrastination Scale, and the Achievement Anxiety Test. They also provided a self-report of their cumulative GPA. Students were divided into two groups by a median-split of 10.5, yielding an internally oriented group of 57 and an externally oriented group of 57. The former students showed significantly lower academic procrastination, debilitating test anxiety, and reported higher academic achievement than the latter.

  10. Frontline diagnostic evaluation of patients suspected of angina by coronary computed tomography reduces downstream resource utilization when compared to conventional ischemia testing

    DEFF Research Database (Denmark)

    Nielsen, L. H.; Markenvard, John; Jensen, Jesper Møller

    2011-01-01

    It has been proposed that the increasing use of coronary computed tomographic angiography (CTA) may introduce additional unnecessary diagnostic procedures. However, no previous study has assessed the impact on downstream test utilization of conventional diagnostic testing relative to CTA in patie...... prospective trials are needed in order to define the most cost-effective diagnostic use of CTA relative to conventional ischemia testing....

  11. Clinical Evaluation of Rapid Diagnostic Test Kit for Scrub Typhus with Improved Performance.

    Science.gov (United States)

    Kim, Young-Jin; Park, Sungman; Premaratna, Ranjan; Selvaraj, Stephen; Park, Sang-Jin; Kim, Sora; Kim, Donghwan; Kim, Min Soo; Shin, Dong Hoon; Choi, Kyung-Chan; Kwon, Soon-Hwan; Seo, Wonjun; Lee, Nam Taek; Kim, Seung-Han; Kang, Heui Keun; Kim, Yoon-Won

    2016-08-01

    Diagnosis of scrub typhus is challenging due to its more than twenty serotypes and the similar clinical symptoms with other acute febrile illnesses including leptospirosis, murine typhus and hemorrhagic fever with renal syndrome. Accuracy and rapidity of a diagnostic test to Orientia tsutsugamushi is an important step to diagnose this disease. To discriminate scrub typhus from other diseases, the improved ImmuneMed Scrub Typhus Rapid Diagnostic Test (RDT) was evaluated in Korea and Sri Lanka. The sensitivity at the base of each IgM and IgG indirect immunofluorescent assay (IFA) in Korean patients was 98.6% and 97.1%, and the specificity was 98.2% and 97.7% respectively. The sensitivity and specificity for retrospective diagnosis at the base of IFA in Sri Lanka was 92.1% and 96.1%. ImmuneMed RDT was not reactive to any serum from seventeen diseases including hemorrhagic fever with renal syndrome (n = 48), leptospirosis (n = 23), and murine typhus (n = 48). ImmuneMed RDT shows superior sensitivity (98.6% and 97.1%) compared with SD Bioline RDT (84.4% at IgM and 83.3% at IgG) in Korea. The retrospective diagnosis of ImmuneMed RDT exhibits 94.0% identity with enzyme-linked Immunosorbent assay (ELISA) using South India patient serum samples. These results suggest that this RDT can replace other diagnostic tests and is applicable for global diagnosis of scrub typhus. This rapid and accurate diagnosis will be beneficial for diagnosing and managing scrub typhus.

  12. Addressing Barriers to the Development and Adoption of Rapid Diagnostic Tests in Global Health

    Directory of Open Access Journals (Sweden)

    Eric Miller

    2015-06-01

    Full Text Available Immunochromatographic rapid diagnostic tests (RDTs have demonstrated significant potential for use as point-of- care diagnostic tests in resource-limited settings. Most notably, RDTs for malaria have reached an unparalleled level of technological maturity and market penetration, and are now considered an important complement to standard microscopic methods of malaria diagnosis. However, the technical development of RDTs for other infectious diseases, and their uptake within the global health community as a core diagnostic modality, has been hindered by a number of extant challenges. These range from technical and biological issues, such as the need for better affinity agents and biomarkers of disease, to social, infrastructural, regulatory and economic barriers, which have all served to slow their adoption and diminish their impact. In order for the immunochromatographic RDT format to be successfully adapted to other disease targets, to see widespread distribution, and to improve clinical outcomes for patients on a global scale, these challenges must be identified and addressed, and the global health community must be engaged in championing the broader use of RDTs.

  13. Addressing Barriers to the Development and Adoption of Rapid Diagnostic Tests in Global Health

    Directory of Open Access Journals (Sweden)

    Eric Miller

    2015-06-01

    Full Text Available Immunochromatographic rapid diagnostic tests (RDTs have demonstrated significant potential for use as point-of-care diagnostic tests in resource-limited settings. Most notably, RDTs for malaria have reached an unparalleled level of technological maturity and market penetration, and are now considered an important complement to standard microscopic methods of malaria diagnosis. However, the technical development of RDTs for other infectious diseases, and their uptake within the global health community as a core diagnostic modality, has been hindered by a number of extant challenges. These range from technical and biological issues, such as the need for better affinity agents and biomarkers of disease, to social, infrastructural, regulatory and economic barriers, which have all served to slow their adoption and diminish their impact. In order for the immunochromatographic RDT format to be successfully adapted to other disease targets, to see widespread distribution, and to improve clinical outcomes for patients on a global scale, these challenges must be identified and addressed, and the global health community must be engaged in championing the broader use of RDTs.

  14. Addressing Barriers to the Development and Adoption of Rapid Diagnostic Tests in Global Health.

    Science.gov (United States)

    Miller, Eric; Sikes, Hadley D

    Immunochromatographic rapid diagnostic tests (RDTs) have demonstrated significant potential for use as point-of-care diagnostic tests in resource-limited settings. Most notably, RDTs for malaria have reached an unparalleled level of technological maturity and market penetration, and are now considered an important complement to standard microscopic methods of malaria diagnosis. However, the technical development of RDTs for other infectious diseases, and their uptake within the global health community as a core diagnostic modality, has been hindered by a number of extant challenges. These range from technical and biological issues, such as the need for better affinity agents and biomarkers of disease, to social, infrastructural, regulatory and economic barriers, which have all served to slow their adoption and diminish their impact. In order for the immunochromatographic RDT format to be successfully adapted to other disease targets, to see widespread distribution, and to improve clinical outcomes for patients on a global scale, these challenges must be identified and addressed, and the global health community must be engaged in championing the broader use of RDTs.

  15. A weighted generalized score statistic for comparison of predictive values of diagnostic tests.

    Science.gov (United States)

    Kosinski, Andrzej S

    2013-03-15

    Positive and negative predictive values are important measures of a medical diagnostic test performance. We consider testing equality of two positive or two negative predictive values within a paired design in which all patients receive two diagnostic tests. The existing statistical tests for testing equality of predictive values are either Wald tests based on the multinomial distribution or the empirical Wald and generalized score tests within the generalized estimating equations (GEE) framework. As presented in the literature, these test statistics have considerably complex formulas without clear intuitive insight. We propose their re-formulations that are mathematically equivalent but algebraically simple and intuitive. As is clearly seen with a new re-formulation we presented, the generalized score statistic does not always reduce to the commonly used score statistic in the independent samples case. To alleviate this, we introduce a weighted generalized score (WGS) test statistic that incorporates empirical covariance matrix with newly proposed weights. This statistic is simple to compute, always reduces to the score statistic in the independent samples situation, and preserves type I error better than the other statistics as demonstrated by simulations. Thus, we believe that the proposed WGS statistic is the preferred statistic for testing equality of two predictive values and for corresponding sample size computations. The new formulas of the Wald statistics may be useful for easy computation of confidence intervals for difference of predictive values. The introduced concepts have potential to lead to development of the WGS test statistic in a general GEE setting. Copyright © 2012 John Wiley & Sons, Ltd.

  16. Publishing nutrition research: validity, reliability, and diagnostic test assessment in nutrition-related research.

    Science.gov (United States)

    Gleason, Philip M; Harris, Jeffrey; Sheean, Patricia M; Boushey, Carol J; Bruemmer, Barbara

    2010-03-01

    This is the sixth in a series of monographs on research design and analysis. The purpose of this article is to describe and discuss several concepts related to the measurement of nutrition-related characteristics and outcomes, including validity, reliability, and diagnostic tests. The article reviews the methodologic issues related to capturing the various aspects of a given nutrition measure's reliability, including test-retest, inter-item, and interobserver or inter-rater reliability. Similarly, it covers content validity, indicators of absolute vs relative validity, and internal vs external validity. With respect to diagnostic assessment, the article summarizes the concepts of sensitivity and specificity. The hope is that dietetics practitioners will be able to both use high-quality measures of nutrition concepts in their research and recognize these measures in research completed by others. Copyright 2010 American Dietetic Association. Published by Elsevier Inc. All rights reserved.

  17. CT-guided transthoracic core needle biopsy for small pulmonary lesions: diagnostic performance and adequacy for molecular testing.

    Science.gov (United States)

    Tian, Panwen; Wang, Ye; Li, Lei; Zhou, Yongzhao; Luo, Wenxin; Li, Weimin

    2017-02-01

    Computed tomography (CT)-guided transthoracic needle biopsy is a well-established, minimally invasive diagnostic tool for pulmonary lesions. Few large studies have been conducted on the diagnostic performance and adequacy for molecular testing of transthoracic core needle biopsy (TCNB) for small pulmonary lesions. This study included CT-guided TCNB with 18-gauge cutting needles in 560 consecutive patients with small (≤3 cm) pulmonary lesions from January 2012 to January 2015. There were 323 males and 237 females, aged 51.8±12.7 years. The size of the pulmonary lesions was 1.8±0.6 cm. The sensitivity, specificity, accuracy and complications of the biopsies were investigated. The risk factors of diagnostic failure were assessed using univariate and multivariate analyses. The sample's adequacy for molecular testing of non-small cell lung cancer (NSCLC) was analyzed. The overall sensitivity, specificity, and accuracy for diagnosis of malignancy were 92.0% (311/338), 98.6% (219/222), and 94.6% (530/560), respectively. The incidence of bleeding complications was 22.9% (128/560), and the incidence of pneumothorax was 10.4% (58/560). Logistic multivariate regression analysis showed that the independent risk factors for diagnostic failure were a lesion size ≤1 cm [odds ratio (OR), 3.95; P=0.007], lower lobe lesions (OR, 2.83; P=0.001), and pneumothorax (OR, 1.98; P=0.004). Genetic analysis was successfully performed on 95.45% (168/176) of specimens diagnosed as NSCLC. At least 96.8% of samples with two or more passes from a lesion were sufficient for molecular testing. The diagnostic yield of small pulmonary lesions by CT-guided TCNB is high, and the procedure is relatively safe. A lesion size ≤1 cm, lower lobe lesions, and pneumothorax are independent risk factors for biopsy diagnostic failure. TCNB specimens could provide adequate tissues for molecular testing.

  18. Recall Tests Are Effective to Detect Mild Cognitive Impairment: A Systematic Review and Meta-analysis of 108 Diagnostic Studies.

    Science.gov (United States)

    Tsoi, Kelvin K F; Chan, Joyce Y C; Hirai, Hoyee W; Wong, Adrian; Mok, Vincent C T; Lam, Linda C W; Kwok, Timothy C Y; Wong, Samuel Y S

    2017-09-01

    Mild cognitive impairment (MCI) is a prevalent symptom associated with the increased risk of dementia. There are many cognitive tests available for detection of MCI, and investigation of the diagnostic performance of the tests is deemed necessary. This study aims to evaluate the diagnostic performance of different cognitive tests used for MCI detection. A list of cognitive tests was identified in previous reviews and from online search engines. Literature searches were performed on each of the cognitive tests in MEDLINE, Embase, and PsycINFO from the earliest available dates of individual databases to December 31, 2016. Google Scholar was used as a supplementary search tool. Studies that were used to assess the diagnostic performance of the cognitive tests were extracted with inclusion and exclusion criteria. Each test's performance was compared with the standard diagnostic criteria. Bivariate random effects models were used to summarize the test performance as a point estimate for sensitivity and specificity, and presented in a summary receiver operating characteristic curve. Reporting quality and risk of bias were evaluated. A total of 108 studies with 23,546 participants were selected to evaluate 9 cognitive tests for MCI detection. Most of the studies used the Mini-Mental State Examination (MMSE) (n = 58) and the Montreal Cognitive Assessment (MoCA) (n = 35). The combined diagnostic performance of the MMSE in MCI detection was 0.71 sensitivity [95% confidence interval (CI): 0.66-0.75] and 0.74 specificity (95% CI: 0.70-0.78), and of the MoCA in MCI detection was 0.83 sensitivity (95% CI: 0.80-0.86) and 0.75 specificity (95% CI: 0.69-0.80). Among the 9 cognitive tests, recall tests showed the best diagnostic performance with 0.89 sensitivity (95% CI: 0.86-0.92) and 0.84 specificity (95% CI, 0.79-0.89). In subgroup analyses, long- or short-delay recall tests have shown better performance than immediate recall tests. Recall tests were shown to be the most

  19. Evaluation of the Ortho-Clinical Diagnostics Vitros ECi Anti-HCV test: comparison with three other methods.

    Science.gov (United States)

    Watterson, Jeannette M; Stallcup, Paulina; Escamilla, David; Chernay, Patrick; Reyes, Alfred; Trevino, Sylvia C

    2007-01-01

    After observing a high incidence of low positive hepatitis C virus (HCV) antibody screens by the Ortho-Clinical Vitros ECi test (Orthoclinical Diagnostics, Raritan, NJ), we compared results against those obtained using another chemiluminescent analyzer, as well as two U.S. Food and Drug Administration (FDA)-approved confirmatory methodologies. To ascertain the true anti-HCV status of samples deemed low-positive by the Ortho-Clinical Vitros ECi test, we tested samples using the ADVIA Centaur HCV screen test (Siemens Medical Solutions Diagnostics), the Chiron recombinant immunoblot assay (RIBA) test (Chiron Corp., Emeryville, CA), and the Roche COBAS Amplicor HCV qualitative test (Roche Diagnostics, Indianapolis, IN) in a series of studies. Of 94 specimens positive by Vitros ECi, 19% were observed to be negative by Centaur. A separate study of 91 samples with signal-to-cutoff (s/co) values less than 8.0 showed that all but one was negative for HCV ribonucleic acid (RNA). In comparison with RIBA, 100% (77) samples positive by the Vitros ECi test with s/co values less than 12.0 were negative or indeterminate by RIBA. A final study comparing all four methods side-by-side showed 63% disagreement by Centaur for Vitros ECi low-positive samples, 75% disagreement by RIBA, and 97% disagreement by polymerase chain reaction (PCR). In conclusion, the Ortho-Clinical Vitros ECi Anti-HCV test yields a high rate of false-positive results in the low s/co range in our patient population. (c) 2007 Wiley-Liss, Inc.

  20. Implementation of Rapid Molecular Infectious Disease Diagnostics: the Role of Diagnostic and Antimicrobial Stewardship.

    Science.gov (United States)

    Messacar, Kevin; Parker, Sarah K; Todd, James K; Dominguez, Samuel R

    2017-03-01

    New rapid molecular diagnostic technologies for infectious diseases enable expedited accurate microbiological diagnoses. However, diagnostic stewardship and antimicrobial stewardship are necessary to ensure that these technologies conserve, rather than consume, additional health care resources and optimally affect patient care. Diagnostic stewardship is needed to implement appropriate tests for the clinical setting and to direct testing toward appropriate patients. Antimicrobial stewardship is needed to ensure prompt appropriate clinical action to translate faster diagnostic test results in the laboratory into improved outcomes at the bedside. This minireview outlines the roles of diagnostic stewardship and antimicrobial stewardship in the implementation of rapid molecular infectious disease diagnostics. Copyright © 2017 American Society for Microbiology.

  1. Test Review: D. Wechsler "Wechsler Individual Achievement Test" (3rd ed.). San Antonio, Texas--Pearson, 2009

    Science.gov (United States)

    Vaughan-Jensen, Jessica; Adame, Cindy; McLean, Lauren; Gamez, Brenda

    2011-01-01

    This article reviews "Wechsler Individual Achievement Test-Third Edition" (WIAT-III), which is designed to assess students' skills in listening, speaking, reading, writing, and mathematics. The test can identify an individual's strengths and weaknesses, assist professionals who are determining whether a student is eligible for special…

  2. Real-world utilization of molecular diagnostic testing and matched drug therapies in the treatment of metastatic cancers.

    Science.gov (United States)

    Chawla, Anita; Peeples, Miranda; Li, Nanxin; Anhorn, Rachel; Ryan, Jason; Signorovitch, James

    2018-06-01

    To assess the frequency of biopsies and molecular diagnostic testing (human DNA/RNA analysis), anti-cancer drug use (genomically-matched targeted therapy [GMTT], unmatched targeted therapy [UTT], endocrine therapy [ET], and chemotherapy [CT]), and medical service costs among adults with metastatic cancer. Adults diagnosed with metastatic breast, non-small cell lung (NSCLC), colorectal, head and neck, ovarian, and uterine cancer (2010Q1-2015Q1) were identified in the OptumHealth Care Solutions claims database and followed from first metastatic diagnosis for ≥1 month and until the end of data availability. Utilization was assessed for each cancer cohort (all and patients aged ≥65 years); per-patient-per-month (PPPM) medical service costs were assessed for all patients. Testing frequency estimates were applied to Surveillance, Epidemiology, and End Results Program data to estimate the number of untested patients (2010-2014). Patients with metastatic cancer (n = 8,193; breast [n = 3,414], NSCLC [n = 2,231], colorectal [n = 1,611], head and neck [n = 511], ovarian [n = 275], and uterine [n = 151]) were 63 years old (mean), with 11.1-22.2 months of observation. Biopsy and molecular diagnostic testing frequencies ranged from 7% (uterine) to 73% (ovarian), and from 34% (head and neck) to 52% (breast), respectively. Few were treated with GMTT (breast, 11%; NSCLC, 9%; colorectal, 6%). Treatment with UTT ranged from 0.7% (uterine) to 21% (colorectal). Biopsy, diagnostic testing, and anti-cancer drug therapy were less frequent for those ≥65 years. Medical service costs (PPPM, mean) ranged from $6,618 (head and neck) to $9,940 (ovarian). The estimated number of untested new patients with metastatic cancer was 636,369 (all) and 341,397 (≥65). In addition to the limitations of claims analyses, diagnostic testing frequency may be under-estimated if patients underwent testing prior to study inclusion. The low frequency of molecular diagnostic

  3. Held Back: The Impact of Curricular and Pedagogical Factors on Tested Achievement in High School Mathematics

    Science.gov (United States)

    Agvanian, Zara

    2013-01-01

    This study examined the impact of curricular factors and teaching practices on students' tested achievement in mathematics, explored the best predictors of the tested achievement, and examined differences in the tested achievement among student subgroups. The study utilized qualitative and quantitative methods and triangulated findings from…

  4. Post-mortem diagnostics in cases of sepsis. Part 1. Aetiology, epidemiology and microbiological tests

    Directory of Open Access Journals (Sweden)

    Marta Rorat

    2015-03-01

    Full Text Available Clinical practice has an effective methodology of diagnostic procedures to be followed in cases of sepsis. However, there are as yet no corresponding standards of action in post-mortem diagnostics. The scope of examinations is limited to an autopsy and histopathological tests. This situation may lead to errors in medico-legal opinions on the cause of death and in the assessment of appropriateness of medical procedures. In cases of suspected sepsis, medico-legal investigations require obtaining detailed information about the circumstances of death (including symptoms and results of intravital examinations before autopsy is performed, as well as sterile collection of specimens for microbiological tests and interpretation of their results on the basis of knowledge of epidemiology, pathophysiology and clinical progression of sepsis.

  5. A Global Comparative Evaluation of Commercial Immunochromatographic Rapid Diagnostic Tests for Visceral Leishmaniasis

    NARCIS (Netherlands)

    Cunningham, Jane; Hasker, Epco; Das, Pradeep; El Safi, Sayda; Goto, Hiro; Mondal, Dinesh; Mbuchi, Margaret; Mukhtar, Maowia; Rabello, Ana; Rijal, Suman; Sundar, Shyam; Wasunna, Monique; Adams, Emily; Menten, Joris; Peeling, Rosanna; Boelaert, Marleen; Khanal, Basudha; Das, Murari; Oliveira, Edward; de Assis, Tália Machado; Costa, Dorcas Lamounier; Bhaskar, Khondaker Rifathassan; Huda, M. Mamun; Hassan, Mukidul; Abdoun, Asim Osman; Awad, Aymen; Osman, Mohamed; Prajapati, Dinesh Kumar; Gidwani, Kamlesh; Tiwary, Puja; Paniago, Anamaria Mello Miranda; Sanchez, Maria Carmen Arroyo; Celeste, Beatriz Julieta; Jacquet, Diane; Magiri, Charles; Muia, A.; Kesusu, J.; Ageed, Al Farazdag; Galal, Nuha; Osman, Osman Salih; Gupta, A. K.; Bimal, Afrad S.; Das, V. N. R.

    2012-01-01

    Background. Poor access to diagnosis stymies control of visceral leishmaniasis (VL). Antibody-detecting rapid diagnostic tests (RDTs) can be performed in peripheral health settings. However, there are many brands available and published reports of variable accuracy. Methods. Commercial VL RDTs

  6. The impact of a computerised test of attention and activity (QbTest) on diagnostic decision-making in children and young people with suspected attention deficit hyperactivity disorder: single-blind randomised controlled trial.

    Science.gov (United States)

    Hollis, Chris; Hall, Charlotte L; Guo, Boliang; James, Marilyn; Boadu, Janet; Groom, Madeleine J; Brown, Nikki; Kaylor-Hughes, Catherine; Moldavsky, Maria; Valentine, Althea Z; Walker, Gemma M; Daley, David; Sayal, Kapil; Morriss, Richard

    2018-04-26

    Diagnosis of attention deficit hyperactivity disorder (ADHD) relies on subjective methods which can lead to diagnostic uncertainty and delay. This trial evaluated the impact of providing a computerised test of attention and activity (QbTest) report on the speed and accuracy of diagnostic decision-making in children with suspected ADHD. Randomised, parallel, single-blind controlled trial in mental health and community paediatric clinics in England. Participants were 6-17 years-old and referred for ADHD diagnostic assessment; all underwent assessment-as-usual, plus QbTest. Participants and their clinician were randomised to either receive the QbTest report immediately (QbOpen group) or the report was withheld (QbBlind group). The primary outcome was number of consultations until a diagnostic decision confirming/excluding ADHD within 6-months from baseline. Health economic cost-effectiveness and cost utility analysis was conducted. Assessing QbTest Utility in ADHD: A Randomised Controlled Trial was registered at ClinicalTrials.gov (https://clinicaltrials.gov/ct2/show/NCT02209116). One hundred and thirty-two participants were randomised to QbOpen group (123 analysed) and 135 to QbBlind group (127 analysed). Clinicians with access to the QbTest report (QbOpen) were more likely to reach a diagnostic decision about ADHD (hazard ratio 1.44, 95% CI 1.04-2.01). At 6-months, 76% of those with a QbTest report had received a diagnostic decision, compared with 50% without. QbTest reduced appointment length by 15% (time ratio 0.85, 95% CI 0.77-0.93), increased clinicians' confidence in their diagnostic decisions (odds ratio 1.77, 95% CI 1.09-2.89) and doubled the likelihood of excluding ADHD. There was no difference in diagnostic accuracy. Health economic analysis showed a position of strict dominance; however, cost savings were small suggesting that the impact of providing the QbTest report within this trial can best be viewed as 'cost neutral'. QbTest may increase the

  7. Synthesis of evidence of diagnostic tests and preventive programs identifying pre-diabetes type

    Directory of Open Access Journals (Sweden)

    Dagmar Tučková

    2015-09-01

    Full Text Available Introduction: Type 2 diabetes mellitus (T2D has become the main type of diabetes in children and it is expected that in countries with high income diabetes it is projected to be one of the leading causes of death by 2030. Another fact is that programs and tests diagnosing pre-diabetes type 2 (T2P-DMC are missing. Methods: The aim of the paper is to present the steps for the synthesis of the evidence within the brand new type of the systematic review (SR: SR of diagnostic test accuracy (DTA. Using the acronym PIRD it was developed a review question, search strategy and inclusion and exclusion criteria. Results: The initial search was done in two databases (MedLine and Cinahl with 2 025 results. The second search after the improvement of the sensitivity and the specificity was done in 15 databases with 3 681 results. Conclusion: This methodological paper introduces how to conduct the systematic review protocols of diagnostic test accuracy on the example of T2P-DMC.

  8. Quality control test solutions for diagnostic radiology, nuclear medicine and health physics with PTW equipment

    International Nuclear Information System (INIS)

    Froescher, Olga

    2007-01-01

    Complete test of publication follows. In 1922 PTW-Freiburg was founded to produce and market a revolutionary new electromechanical component for measuring very small electrical charges. Today PTW is the specialist and one of the global market leaders for manufacturing and supplying high-quality products in diagnostic radiology, nuclear medicine, radiation therapy and health physics. The quality control of X-ray images is influenced by a number of parameters. To maintain a consistent performance of X-ray installations, quality checks have to be conducted regularly. PTW offers a variety of diagnostic test tools for different X-ray devices, and therefore to reduce patient exposure and costs for X-ray departments. PTW's 'Code of Practice' defines in an easy and compact way how to perform quality control measurements on different diagnostic X-ray installations. The necessary equipment for measuring main parameters as well as acceptable limits are mentioned accordingly. The 'Code of Practice' bases on actual standards.

  9. Diagnostic grand rounds: A new teaching concept to train diagnostic reasoning

    International Nuclear Information System (INIS)

    Stieger, Stefan; Praschinger, Andrea; Kletter, Kurt; Kainberger, Franz

    2011-01-01

    Introduction: Diagnostic reasoning is a core skill in teaching and learning in undergraduate curricula. Diagnostic grand rounds (DGRs) as a subform of grand rounds are intended to train the students' skills in the selection of appropriate tests and in the interpretation of test results. The aim of this study was to test DGRs for their ability to improve diagnostic reasoning by using a pre-post-test design. Methods: During one winter term, all 398 fifth-year students (36.1% male, 63.9% female) solved 23 clinical cases presented in 8 DGRs. In an online questionnaire, a Diagnostic Thinking Inventory (DTI) with 41 items was evaluated for flexibility in thinking and structure of knowledge in memory. Results were correlated with those from a summative multiple-choice knowledge test and of the learning objectives in a logbook. Results: The students' DTI scores in the post-test were significantly higher than those reported in the pre-test. DTI scores at either testing time did not correlate with medical knowledge as assessed by a multiple-choice knowledge test. Abilities acquired during clinical clerkships as documented in a logbook could only account for a small proportion of the increase in the flexibility subscale score. This effect still remained significant after accounting for potential confounders. Conclusion: Establishing DGRs proofed to be an effective way of successfully improving both students' diagnostic reasoning and the ability to select the appropriate test method in routine clinical practice.

  10. Diagnostic grand rounds: A new teaching concept to train diagnostic reasoning

    Energy Technology Data Exchange (ETDEWEB)

    Stieger, Stefan, E-mail: stefan.stieger@univie.ac.at [Department of Basic Psychological Research, School of Psychology, University of Vienna, Liebiggasse 5, A-1010 Vienna (Austria); Praschinger, Andrea, E-mail: andrea.praschinger@meduniwien.ac.at [Core Unit for Medical Education (BEMAW), Medical University of Vienna, Spitalgasse 23, BT87, P.O. 10, A-1097 Vienna (Austria); Kletter, Kurt, E-mail: kurt.kletter@meduniwien.ac.at [Department of Nuclear Medicine, General Hospital of Vienna, Waehringer Guertel 18-20, A-1090 Vienna (Austria); Kainberger, Franz, E-mail: franz.kainberger@meduniwien.ac.at [Department of Radiology, General Hospital of Vienna, Waehringer Guertel 18-20, A-1090 Vienna (Austria)

    2011-06-15

    Introduction: Diagnostic reasoning is a core skill in teaching and learning in undergraduate curricula. Diagnostic grand rounds (DGRs) as a subform of grand rounds are intended to train the students' skills in the selection of appropriate tests and in the interpretation of test results. The aim of this study was to test DGRs for their ability to improve diagnostic reasoning by using a pre-post-test design. Methods: During one winter term, all 398 fifth-year students (36.1% male, 63.9% female) solved 23 clinical cases presented in 8 DGRs. In an online questionnaire, a Diagnostic Thinking Inventory (DTI) with 41 items was evaluated for flexibility in thinking and structure of knowledge in memory. Results were correlated with those from a summative multiple-choice knowledge test and of the learning objectives in a logbook. Results: The students' DTI scores in the post-test were significantly higher than those reported in the pre-test. DTI scores at either testing time did not correlate with medical knowledge as assessed by a multiple-choice knowledge test. Abilities acquired during clinical clerkships as documented in a logbook could only account for a small proportion of the increase in the flexibility subscale score. This effect still remained significant after accounting for potential confounders. Conclusion: Establishing DGRs proofed to be an effective way of successfully improving both students' diagnostic reasoning and the ability to select the appropriate test method in routine clinical practice.

  11. Diagnostic value of patient characteristics, history, and six clinical tests for traumatic anterior shoulder instability

    NARCIS (Netherlands)

    van Kampen, D.A.; van den Berg, T.; van der Woude, H.J.; Castelein, R.M.; Terwee, C.B.; Willems, W.J.

    2013-01-01

    Background: It is unknown which combination of patient information and clinical tests might beoptimal for the diagnosis of traumatic anterior shoulder instability. This study aimed to determinethe diagnostic value of individual clinical tests and to develop a prediction model that combined patient

  12. The bone diagnostic instrument III: Testing mouse femora

    Science.gov (United States)

    Randall, Connor; Mathews, Phillip; Yurtsev, Eugene; Sahar, Nadder; Kohn, David; Hansma, Paul

    2009-06-01

    Here we describe modifications that allow the bone diagnostic instrument (BDI) [P. Hansma et al., Rev. Sci. Instrum. 79, 064303 (2008); Rev. Sci. Instrum. 77, 075105 (2006)], developed to test human bone, to test the femora of mice. These modifications include reducing the effective weight of the instrument on the bone, designing and fabricating new probe assemblies to minimize damage to the small bone, developing new testing protocols that involve smaller testing forces, and fabricating a jig for securing the smaller bones for testing. With these modifications, the BDI was used to test the hypothesis that short-term running has greater benefit on the mechanical properties of the femur for young growing mice compared to older, skeletally mature mice. We measured elastic modulus, hardness, and indentation distance increase (IDI), which had previously been shown to be the best discriminators in model systems known to exhibit differences in mechanical properties at the whole bone level. In the young exercised murine femora, the IDI was significantly lower than in young control femora. Since IDI has a relation to postyield properties, these results suggest that exercise during bone development increases post yield mechanical competence. We were also able to measure effects of aging on bone properties with the BDI. There was a significant increase in the IDI, and a significant decrease in the elastic modulus and hardness between the young and old groups. Thus, with the modifications described here, the BDI can take measurements on mouse bones and obtain statistically significant results.

  13. Feasibility of using microbiology diagnostic tests of moderate or high complexity at the point - of - care in a delivery suite.

    Science.gov (United States)

    Gray, J W; Milner, P J; Edwards, E H; Daniels, J P; Khan, K S

    2012-07-01

    Point-of-care testing (POCT) is one of the fastest growing sectors of laboratory diagnostics. Most tests in routine use are haematology or biochemistry tests that are of low complexity. Microbiology POCT has been constrained by a lack of tests that are both accurate and of low complexity. We describe our experience of the practical issues around using more complex POCT for detection of Group B streptococci (GBS) in swabs from labouring women. We evaluated two tests for their feasibility in POCT: an optical immune assay (Biostar OIA Strep B, Inverness Medical, Princetown, NJ) and a PCR (IDI-Strep B, Cepheid, Sunnyvale, CA), which have been categorised as being of moderate and high complexity, respectively. A total of 12 unqualified midwifery assistants (MA) were trained to undertake testing on the delivery suite. A systematic approach to the introduction and management of POC testing was used. Modelling showed that the probability of test results being available within a clinically useful timescale was high. However, in the clinical setting, we found it impossible to maintain reliable availability of trained testers. Implementation of more complex POC testing is technically feasible, but it is expensive, and may be difficult to achieve in a busy delivery suite.

  14. Sensitive KIT D816V mutation analysis of blood as a diagnostic test in mastocytosis

    DEFF Research Database (Denmark)

    Kielsgaard Kristensen, Thomas; Vestergaard, Hanne; Bindslev-Jensen, Carsten

    2014-01-01

    The recent progress in sensitive KIT D816V mutation analysis suggests that mutation analysis of peripheral blood (PB) represents a promising diagnostic test in mastocytosis. However, there is a need for systematic assessment of the analytical sensitivity and specificity of the approach in order...... to establish its value in clinical use. We therefore evaluated sensitive KIT D816V mutation analysis of PB as a diagnostic test in an entire case-series of adults with mastocytosis. We demonstrate for the first time that by using a sufficiently sensitive KIT D816V mutation analysis, it is possible to detect...... the mutation in PB in nearly all adult mastocytosis patients. The mutation was detected in PB in 78 of 83 systemic mastocytosis (94%) and 3 of 4 cutaneous mastocytosis patients (75%). The test was 100% specific as determined by analysis of clinically relevant control patients who all tested negative. Mutation...

  15. State of malaria diagnostic testing at clinical laboratories in the United States, 2010: a nationwide survey

    Directory of Open Access Journals (Sweden)

    Abanyie Francisca A

    2011-11-01

    Full Text Available Abstract Background The diagnosis of malaria can be difficult in non-endemic areas, such as the United States, and delays in diagnosis and errors in treatment occur too often. Methods A nationwide survey of laboratories in the United States and its nine dependent territories was conducted in 2010 to determine factors that may contribute to shortcomings in the diagnosis of malaria. This survey explored the availability of malaria diagnostic tests, techniques used, and reporting practices. Results The survey was completed by 201 participants. Ninety percent reported that their laboratories had at least one type of malaria diagnostic test available on-site. Nearly all of the respondents' laboratories performed thick and thin smears on-site; approximately 50% had access to molecular testing; and only 17% had access to rapid diagnostic tests on-site. Seventy-three percent reported fewer than five confirmed cases of malaria in their laboratory during the 12-month period preceding the survey. Twenty-eight percent stated that results of species identification took more than 24 hours to report. Only five of 149 respondents that performed testing 24 hours a day, 7 days a week complied with all of the Clinical and Laboratory Standards Institute (CLSI guidelines for analysis and reporting of results. Conclusion Although malaria diagnostic testing services were available to a majority of U.S. laboratories surveyed, very few were in complete compliance with all of the CLSI guidelines for analysis and reporting of results, and most respondents reported very few cases of malaria annually. Laboratories' difficulty in adhering to the rigorous CLSI guidelines and their personnel's lack of practice and proficiency may account for delays and errors in diagnosis. It is recommended that laboratories that infrequently process samples for malaria seek opportunities for practice and proficiency training annually and take advantage of available resources to assist in

  16. Is Serial Testing Required to Diagnose Imported Malaria in the Era of Rapid Diagnostic Tests?

    Science.gov (United States)

    Pasricha, Janet M.; Juneja, Surender; Manitta, Joseph; Whitehead, Susan; Maxwell, Ellen; Goh, Wai-Keong; Pasricha, Sant-Rayn; Eisen, Damon P.

    2013-01-01

    Exclusion of malaria traditionally requires three negative serial thick and thin blood films. However, many clinical laboratories now routinely perform rapid diagnostic tests (RDTs) in addition to blood films when malaria is suspected. We sought to determine whether serial testing is necessary in this setting. We examined 388 cases of malaria diagnosed during 1999–2010 at three laboratories in Melbourne, Australia. For each case, we ascertained whether the diagnosis was made on initial or follow-up testing. Nine cases (3.5%) were diagnosed after a negative initial blood film and RDT: 7 Plasmodium vivax, 1 P. ovale, and 1 P. falciparum. Of four case-patients with P. vivax in which clinical data were available, all had recent exposure to antimalarial medication. Our data suggest that among patients who have not received recent anti-malarial therapy, and when RDTs are performed and blood films are prepared, most malaria diagnoses are made by using the first set of tests. PMID:23208885

  17. Student certainty answering misconception question: study of Three-Tier Multiple-Choice Diagnostic Test in Acid-Base and Solubility Equilibrium

    Science.gov (United States)

    Ardiansah; Masykuri, M.; Rahardjo, S. B.

    2018-04-01

    Students’ concept comprehension in three-tier multiple-choice diagnostic test related to student confidence level. The confidence level related to certainty and student’s self-efficacy. The purpose of this research was to find out students’ certainty in misconception test. This research was quantitative-qualitative research method counting students’ confidence level. The research participants were 484 students that were studying acid-base and equilibrium solubility subject. Data was collected using three-tier multiple-choice (3TMC) with thirty questions and students’ questionnaire. The findings showed that #6 item gives the highest misconception percentage and high student confidence about the counting of ultra-dilute solution’s pH. Other findings were that 1) the student tendency chosen the misconception answer is to increase over item number, 2) student certainty decreased in terms of answering the 3TMC, and 3) student self-efficacy and achievement were related each other in the research. The findings suggest some implications and limitations for further research.

  18. A Three-Tier Diagnostic Test to Assess Pre-Service Teachers' Misconceptions about Global Warming, Greenhouse Effect, Ozone Layer Depletion, and Acid Rain

    Science.gov (United States)

    Arslan, Harika Ozge; Cigdemoglu, Ceyhan; Moseley, Christine

    2012-01-01

    This study describes the development and validation of a three-tier multiple-choice diagnostic test, the atmosphere-related environmental problems diagnostic test (AREPDiT), to reveal common misconceptions of global warming (GW), greenhouse effect (GE), ozone layer depletion (OLD), and acid rain (AR). The development of a two-tier diagnostic test…

  19. Diagnostic value of R wave amplitude changes during exercise testing after myocardial infarction

    NARCIS (Netherlands)

    de Hert, S.; Vrints, C.; Vanagt, E.; Snoeck, J.

    1986-01-01

    To determine the diagnostic value of R wave amplitude changes occurring during exercise testing after myocardial infarction, exercise ECG's and coronary angiograms were reviewed in 76 postinfarction patients and in 40 patients with normal coronary arteries. During exercise, an increase in R wave

  20. Diagnostic testing for celiac disease among patients with abdominal symptoms a systematic review

    NARCIS (Netherlands)

    van der Windt, D.A.W.M.; Jellema, A.P.; Mulder, C.J.J.; Kneepkens, C.M.F.; van der Horst, H.E.

    2010-01-01

    Context: The symptoms and consequences of celiac disease usually resolve with a lifelong gluten-free diet. However, clinical presentation is variable and most patients presenting with abdominal symptoms in primary care will not have celiac disease and unnecessary diagnostic testing should be

  1. Diagnostic testing for celiac disease among patients with abdominal symptoms: a systematic review

    NARCIS (Netherlands)

    van der Windt, Daniëlle A. W. M.; Jellema, Petra; Mulder, Chris J.; Kneepkens, C. M. Frank; van der Horst, Henriëtte E.

    2010-01-01

    The symptoms and consequences of celiac disease usually resolve with a lifelong gluten-free diet. However, clinical presentation is variable and most patients presenting with abdominal symptoms in primary care will not have celiac disease and unnecessary diagnostic testing should be avoided. To

  2. Diagnostic performance of serological tests to detect antibodies against acute scrub typhus infection in central India

    Directory of Open Access Journals (Sweden)

    Kiran Pote

    2018-01-01

    Full Text Available Background: Differentiating scrub typhus from other acute febrile illness is difficult due to non specificity of clinical symptoms and relative absence of eschar in Indian population. The diagnosis thus relies mainly on laboratory tests. Antibody based serological tests are mainstay of scrub typhus diagnosis. Here, we evaluated the diagnostic performance of IgM ELISA, IgM IFA and ICT to detect antibodies against O. tsutsugamushi in acute serum of febrile patients. Methodology: The serum samples from 600 randomly selected patients suffering from acute undifferentiated fever were tested by all the three tests mentioned above. We used latent class analysis to generate unbiased results as all the tests for scrub typhus diagnosis are imperfect and none of them can be considered as reference standard. Results: We found that IgM ELISA with cutoff titer 0.5 OD has high diagnostic accuracy (sensitivity 99.9% and specificity 99.15 than IgM IFA (sensitivity 96.8% and specificity 99.7% for scrub typhus diagnosis. ICT used in our study had very high specificity 100% but low sensitivity (38% which would limit its use for acute serum samples. ICT being a screening or point of care test, has to be more sensitive while some compromise with specificity is affordable. Hence, optimal cutoff for ICT should be evaluated under different settings. Conclusion: IgM ELISA being simple and affordable could be an alternative diagnostic test to IgM IFA which is subjective and costly.

  3. Diagnostic performance of serological tests to detect antibodies against acute scrub typhus infection in central India.

    Science.gov (United States)

    Pote, Kiran; Narang, Rahul; Deshmukh, Pradeep

    2018-01-01

    Differentiating scrub typhus from other acute febrile illness is difficult due to non specificity of clinical symptoms and relative absence of eschar in Indian population. The diagnosis thus relies mainly on laboratory tests. Antibody based serological tests are mainstay of scrub typhus diagnosis. Here, we evaluated the diagnostic performance of IgM ELISA, IgM IFA and ICT to detect antibodies against O. tsutsugamushi in acute serum of febrile patients. The serum samples from 600 randomly selected patients suffering from acute undifferentiated fever were tested by all the three tests mentioned above. We used latent class analysis to generate unbiased results as all the tests for scrub typhus diagnosis are imperfect and none of them can be considered as reference standard. We found that IgM ELISA with cutoff titer 0.5 OD has high diagnostic accuracy (sensitivity 99.9% and specificity 99.15) than IgM IFA (sensitivity 96.8% and specificity 99.7%) for scrub typhus diagnosis. ICT used in our study had very high specificity 100% but low sensitivity (38%) which would limit its use for acute serum samples. ICT being a screening or point of care test, has to be more sensitive while some compromise with specificity is affordable. Hence, optimal cutoff for ICT should be evaluated under different settings. IgM ELISA being simple and affordable could be an alternative diagnostic test to IgM IFA which is subjective and costly.

  4. Physical examination tests of the shoulder: a systematic review and meta-analysis of diagnostic test performance.

    Science.gov (United States)

    Gismervik, Sigmund Ø; Drogset, Jon O; Granviken, Fredrik; Rø, Magne; Leivseth, Gunnar

    2017-01-25

    Physical examination tests of the shoulder (PETS) are clinical examination maneuvers designed to aid the assessment of shoulder complaints. Despite more than 180 PETS described in the literature, evidence of their validity and usefulness in diagnosing the shoulder is questioned. This meta-analysis aims to use diagnostic odds ratio (DOR) to evaluate how much PETS shift overall probability and to rank the test performance of single PETS in order to aid the clinician's choice of which tests to use. This study adheres to the principles outlined in the Cochrane guidelines and the PRISMA statement. A fixed effect model was used to assess the overall diagnostic validity of PETS by pooling DOR for different PETS with similar biomechanical rationale when possible. Single PETS were assessed and ranked by DOR. Clinical performance was assessed by sensitivity, specificity, accuracy and likelihood ratio. Six thousand nine-hundred abstracts and 202 full-text articles were assessed for eligibility; 20 articles were eligible and data from 11 articles could be included in the meta-analysis. All PETS for SLAP (superior labral anterior posterior) lesions pooled gave a DOR of 1.38 [1.13, 1.69]. The Supraspinatus test for any full thickness rotator cuff tear obtained the highest DOR of 9.24 (sensitivity was 0.74, specificity 0.77). Compression-Rotation test obtained the highest DOR (6.36) among single PETS for SLAP lesions (sensitivity 0.43, specificity 0.89) and Hawkins test obtained the highest DOR (2.86) for impingement syndrome (sensitivity 0.58, specificity 0.67). No single PETS showed superior clinical test performance. The clinical performance of single PETS is limited. However, when the different PETS for SLAP lesions were pooled, we found a statistical significant change in post-test probability indicating an overall statistical validity. We suggest that clinicians choose their PETS among those with the highest pooled DOR and to assess validity to their own specific clinical

  5. Clinical relevance of the proposed sexual addiction diagnostic criteria: relation to the Sexual Addiction Screening Test-Revised.

    Science.gov (United States)

    Carnes, Patrick J; Hopkins, Tiffany A; Green, Bradley A

    2014-01-01

    The present article examines and compares the various diagnostic rubrics proposed to codify symptoms of sexual addiction, and then briefly summarizes the ongoing controversy on whether sexual addiction is a valid construct. Using the diagnostic criteria proposed by , the prevalence rate of each criterion is examined in terms of scores on the Sexual Addiction Screening Test-Revised scales (). Differences in diagnostic criteria endorsement associated with sex, sexual orientation, and setting were also explored. Results from a clinical sample of men and women seeking treatment for sexual addiction demonstrated clinical relevance of the criteria, in that all but 3 criteria are endorsed at more than 50% of participants screening positive for sexual addiction on the Sexual Addiction Screening Test-Revised. Sex differences were also noted for endorsement rates of several of the criteria. Finally, several proposed criteria may pose a higher clinical threshold and thus be utilized by clinicians to identify patients with increased pathology. Results are discussed in the context of existing diagnostic frameworks across etiological perspectives.

  6. Evidence synthesis to inform model-based cost-effectiveness evaluations of diagnostic tests: a methodological review of health technology assessments

    Directory of Open Access Journals (Sweden)

    Bethany Shinkins

    2017-04-01

    Full Text Available Abstract Background Evaluations of diagnostic tests are challenging because of the indirect nature of their impact on patient outcomes. Model-based health economic evaluations of tests allow different types of evidence from various sources to be incorporated and enable cost-effectiveness estimates to be made beyond the duration of available study data. To parameterize a health-economic model fully, all the ways a test impacts on patient health must be quantified, including but not limited to diagnostic test accuracy. Methods We assessed all UK NIHR HTA reports published May 2009-July 2015. Reports were included if they evaluated a diagnostic test, included a model-based health economic evaluation and included a systematic review and meta-analysis of test accuracy. From each eligible report we extracted information on the following topics: 1 what evidence aside from test accuracy was searched for and synthesised, 2 which methods were used to synthesise test accuracy evidence and how did the results inform the economic model, 3 how/whether threshold effects were explored, 4 how the potential dependency between multiple tests in a pathway was accounted for, and 5 for evaluations of tests targeted at the primary care setting, how evidence from differing healthcare settings was incorporated. Results The bivariate or HSROC model was implemented in 20/22 reports that met all inclusion criteria. Test accuracy data for health economic modelling was obtained from meta-analyses completely in four reports, partially in fourteen reports and not at all in four reports. Only 2/7 reports that used a quantitative test gave clear threshold recommendations. All 22 reports explored the effect of uncertainty in accuracy parameters but most of those that used multiple tests did not allow for dependence between test results. 7/22 tests were potentially suitable for primary care but the majority found limited evidence on test accuracy in primary care settings

  7. USING OF BYOD MODEL FOR TESTING OF EDUCATIONAL ACHIEVEMENTS ON THE BASIS OF GOOGLE SEARCH SERVICES

    Directory of Open Access Journals (Sweden)

    Tetiana Bondarenko

    2016-04-01

    Full Text Available The technology of using their own mobile devices of learners for testing educational achievements, based on the model of BYOD, in an article is offered. The proposed technology is based on cloud services Google. This technology provides a comprehensive support of testing system: creating appropriate forms, storing the results in cloud storage, processing test results and management of testing system through the use of Google-Calendar. A number of software products based on cloud technologies that allow using BYOD model for testing of educational achievement are described, their strengths and weaknesses are identified. This article also describes the stages of the testing process of the academic achievements of students on the basis of Google search services with using the BYOD model. The proposed approaches to the testing of educational achievements based on using of BYOD model extends the space and time of the testing, makes the test procedure more flexible and systematically, adds to the procedure for testing the elements of a computer game. BYOD model opens up broad prospects for implementation of ICT in all forms of learning process, and particularly in testing of educational achievement in view of the limited computing resources in education

  8. Major Reduction in Anti-Malarial Drug Consumption in Senegal after Nation-Wide Introduction of Malaria Rapid Diagnostic Tests

    Science.gov (United States)

    Thiam, Sylla; Thior, Moussa; Faye, Babacar; Ndiop, Médoune; Diouf, Mamadou Lamine; Diouf, Mame Birame; Diallo, Ibrahima; Fall, Fatou Ba; Ndiaye, Jean Louis; Albertini, Audrey; Lee, Evan; Jorgensen, Pernille; Gaye, Oumar; Bell, David

    2011-01-01

    Background While WHO recently recommended universal parasitological confirmation of suspected malaria prior to treatment, debate has continued as to whether wide-scale use of rapid diagnostic tests (RDTs) can achieve this goal. Adherence of health service personnel to RDT results has been poor in some settings, with little impact on anti-malarial drug consumption. The Senegal national malaria control programme introduced universal parasite-based diagnosis using malaria RDTs from late 2007 in all public health facilities. This paper assesses the impact of this programme on anti-malarial drug consumption and disease reporting. Methods and Findings Nationally-collated programme data from 2007 to 2009 including malaria diagnostic outcomes, prescription of artemisinin-based combination therapy (ACT) and consumption of RDTs in public health facilities, were reviewed and compared. Against a marked seasonal variation in all-cause out-patient visits, non-malarial fever and confirmed malaria, parasite-based diagnosis increased nationally from 3.9% of reported malaria-like febrile illness to 86.0% over a 3 year period. The prescription of ACT dropped throughout this period from 72.9% of malaria-like febrile illness to 31.5%, reaching close equivalence to confirmed malaria (29.9% of 584873 suspect fever cases). An estimated 516576 courses of inappropriate ACT prescription were averted. Conclusions The data indicate high adherence of anti-malarial prescribing practice to RDT results after an initial run-in period. The large reduction in ACT consumption enabled by the move from symptom-based to parasite-based diagnosis demonstrates that effective roll-out and use of malaria RDTs is achievable on a national scale through well planned and structured implementation. While more detailed information on management of parasite-negative cases is required at point of care level to assess overall cost-benefits to the health sector, considerable cost-savings were achieved in ACT

  9. Systematic review and meta-analysis of studies evaluating diagnostic test accuracy: A practical review for clinical researchers-Part II. general guidance and tips

    International Nuclear Information System (INIS)

    Kim, Kyung Won; Choi, Sang Hyun; Huh, Jimi; Park, Seong Ho; Lee, June Young

    2015-01-01

    Meta-analysis of diagnostic test accuracy studies differs from the usual meta-analysis of therapeutic/interventional studies in that, it is required to simultaneously analyze a pair of two outcome measures such as sensitivity and specificity, instead of a single outcome. Since sensitivity and specificity are generally inversely correlated and could be affected by a threshold effect, more sophisticated statistical methods are required for the meta-analysis of diagnostic test accuracy. Hierarchical models including the bivariate model and the hierarchical summary receiver operating characteristic model are increasingly being accepted as standard methods for meta-analysis of diagnostic test accuracy studies. We provide a conceptual review of statistical methods currently used and recommended for meta-analysis of diagnostic test accuracy studies. This article could serve as a methodological reference for those who perform systematic review and meta-analysis of diagnostic test accuracy studies

  10. [Stress-ECG is adequate to detect myocardial ischemia: when are additional diagnostic tests needed?].

    Science.gov (United States)

    Baer, F M

    2007-09-01

    The stress-ECG is the most often adopted and most cost effective initial diagnostic test for the assessment of myocardial ischemia in patients with suspected coronary artery disease (CAD). Prerequisites for the diagnostic usefullness of stress-ECG are a clearly interpretable ST-segment, ability to reach the predicted work load, an intermediate pretest probability for CAD ranging between 10% and 90% and the absence of any contraindications for dynamic exercise. Because of the limited diagnostic sensitivity of about 70%, and a high percentage of patients, who are unable to exercise, a negative stress ECG can definitely not exclude hemodynamically significant CAD. Therefore, stress imaging techniques like myocardial scintigraphy, stress-echocardiography and stress magnetic resonance imaging play a major role in the stepwise diagnostic work-up of patients with suspected CAD. These stress imaging techniques are basically interchangeable since no method is definitely superior to one of the others. However, each method has its specific pros and cons and inherent contraindications. Therefore the choice of the stress imaging method and the form of stress applied should be based on the individual patients characteristics to gain optimal image quality and diagnostic accuracy. Moreover, the decision for one method should take the local availability and institutional expertise of diagnostic centers into account. Although partly substituted by stress imaging techniques the stress-ECG still remains the workhorse for a stepwise diagnostic work-up of patients with suspected CAD.

  11. Accuracy of an Immunochromatographic Diagnostic Test (ICT Malaria Combo Cassette Test) Compared to Microscopy among under Five-Year-Old Children when Diagnosing Malaria in Equatorial Guinea

    Science.gov (United States)

    Portero, José-Luis; Rubio-Yuste, Maria; Descalzo, Miguel Angel; Raso, Jose; Lwanga, Magdalena; Obono, Jaquelina; Nseng, Gloria; Benito, Agustin; Cano, Jorge

    2010-01-01

    Conventional malaria diagnosis based on microscopy raises serious difficulties in weak health systems. Cost-effective and sensitive rapid diagnostic tests have been recently proposed as alternatives to microscopy. In Equatorial Guinea, a study was conducted to assess the reliability of a rapid diagnostic test compared to microscopy. The study was designed in accordance with the directives of the Standards for Reporting Diagnostic Accuracy Initiative (STARD). Peripheral thick and thin films for the microscopy diagnosis and a rapid immunochromatographic test (ICT Malaria Combo Cassette Test) were performed on under five-year-old children with malaria suspicion. The ICT test detected Plasmodium spp. infection with a sensitivity of 81.5% and a specificity of 81.9% while P. falciparum diagnosis occurred with a sensitivity of 69.7% and a specificity of 73.7%. The sensitivity of the ICT test increased with higher parasitemias. The general results showed little concordance between the ICT test and microscopy (kappa = 0.28, se: 0.04). In Equatorial Guinea, the ICT Malaria Combo Cassette Test has proven to be an acceptable test to detect high P. falciparum parasitemias. However, the decrease of sensitivity at medium and low parasitemias hampers that ICT can replace properly performed microscopy at present in the diagnosis of malaria in children. PMID:22332024

  12. Evaluation of the diagnostic performance and operational characteristics of four rapid immunochromatographic syphilis tests in Burkina Faso.

    Science.gov (United States)

    Bocoum, Fadima Yaya; Ouédraogo, Henri; Tarnagda, Grissoum; Kiba, Alice; Tiendrebeogo, Simon; Bationo, Fabrice; Liestman, Benjamin; Diagbouga, Serge; Zarowsky, Christina; Traoré, Ramata Ouédraogo; Kouanda, Séni

    2015-06-01

    Little information is available on the rapid diagnostic testing for syphilis in Burkina Faso. The objectives of the study were (i) to assess the sensitivity and specificity of four on site rapid tests in comparison with Treponema pallidum haemagglutination assay (TPHA) as a gold standard and (ii) to evaluate the operational characteristics of those tests among health workers in a maternity unit. Four rapid syphilis tests commercially available in Burkina Faso were evaluated using archived serum samples and Treponema pallidum hemagglutination assay (TPHA) as the gold standard. Blood samples were collected between November 2011 and June 2012 from blood donors at the Regional Blood Transfusion Center of Ouagadougou. The sensitivity and specificity of the tests were calculated. Evaluation of operational characteristics such as clarity of pamphlet, complexity of technique, duration, was conducted in a first-level healthcare center with health workers in maternity unit. Alere DetermineTM Syphilis was the most sensitive of the four rapid syphilis tests evaluated. It was followed by SD Bioline Syphilis 3.0, Cypress Diagnostics Syphilis Quick test and Accu-Tell ® Rapid Anti-TP, which was the least sensitive. The four tests demonstrated a good diagnostic specificity for syphilis (95-98%), and healthcare workers found them easy to use. The study allowed confirming the good performance of three of four rapid syphilis tests in Burkina Faso. More research will be conducted to assess the feasibility of introducing selected rapid tests for syphilis in antenatal care services.

  13. Parallel Recovery in a Trilingual Speaker: The Use of the Bilingual Aphasia Test as a Diagnostic Complement to the Comprehensive Aphasia Test

    Science.gov (United States)

    Green, David W.; Ruffle, Louise; Grogan, Alice; Ali, Nilufa; Ramsden, Sue; Schofield, Tom; Leff, Alex P.; Crinion, Jenny; Price, Cathy J.

    2011-01-01

    We illustrate the value of the Bilingual Aphasia Test in the diagnostic assessment of a trilingual speaker post-stroke living in England for whom English was a non-native language. The Comprehensive Aphasia Test is routinely used to assess patients in English, but only in combination with the Bilingual Aphasia Test is it possible and practical to…

  14. Accuracy of Triple Diagnostic Test in Patients with Thyroid Nodule at Dr. Cipto Mangunkusumo General Hospital

    Directory of Open Access Journals (Sweden)

    Diani Kartini

    2017-04-01

    Full Text Available The aim of the study is to evaluate the accuracy of triple diagnostic test on thyroid nodules. The data from patients’ medical records who came to Cipto Mangunkusumo General Hospital for the first time or for evaluation of thyroid nodule and patients who underwent thyroidectomy during 2010 to 2011. Clinical examination was scored by McGill Thyroid Nodule Score. ROC procedure was performed to obtain clinical cut-off scores of diagnosis of malignant. Ultrasonography (USG result was considered malignant for TIRADS 4, 5, and 6. If clinical, USG and histopathology examinations of triple diagnostic give positive results, it will be classified as concordant malignant whereas if all those three show benign results, the classification is benign. Thyroid carcinoma was found in 134 out of 161 patients with thyroid nodule. There were 84 patients with concordant results for all three elements of the triple test. Out of 84 patients with concordant triple diagnostic results, there were 53 malignant cases (32.9% and 31 benign cases (19.3%. Main histopathological findings among patients with thyroid carcinoma was papillary (90.3%, follicular (3%, medullary (0.7%, and anaplastic (6%. The sensitivity and specificity of triple diagnostic was 77% and 94%, with positive predictive value of 98%, negative predictive value of 51,6% and accuracy of 80.9%. Combination of clinical findings, USG, and FNAB gave malignant probability of 92%, better than combination of clinical findings and USG (81.6% or clinical findings and FNAB (87%. Triple diagnostic cannot be used as an ideal test to replace frozen section examination in managing thyroid nodule. However, in cases with concordant results of each triple diagnostic’s element, the positive predictive value (98% and malignant probability (92% is high. Keywords: thyroid nodule, triple diagnostic, accuracy.   Akurasi Metode Triple Diagnostic pada Pasien Nodul Tiroid  di RSUPN Dr. Cipto Mangunkusumo   Abstrak Tujuan

  15. Self Diagnostic Accelerometer Ground Testing on a C-17 Aircraft Engine

    Science.gov (United States)

    Tokars, Roger P.; Lekki, John D.

    2013-01-01

    The self diagnostic accelerometer (SDA) developed by the NASA Glenn Research Center was tested for the first time in an aircraft engine environment as part of the Vehicle Integrated Propulsion Research (VIPR) program. The VIPR program includes testing multiple critical flight sensor technologies. One such sensor, the accelerometer, measures vibrations to detect faults in the engine. In order to rely upon the accelerometer, the health of the accelerometer must be ensured. Sensor system malfunction is a significant contributor to propulsion in flight shutdowns (IFSD) which can lead to aircraft accidents when the issue is compounded with an inappropriate crew response. The development of the SDA is important for both reducing the IFSD rate, and hence reducing the rate at which this component failure type can put an aircraft in jeopardy, and also as a critical enabling technology for future automated malfunction diagnostic systems. The SDA is a sensor system designed to actively determine the accelerometer structural health and attachment condition, in addition to making vibration measurements. The SDA uses a signal conditioning unit that sends an electrical chirp to the accelerometer and recognizes changes in the response due to changes in the accelerometer health and attachment condition. In an effort toward demonstrating the SDAs flight worthiness and robustness, multiple SDAs were mounted and tested on a C-17 aircraft engine. The engine test conditions varied from engine off, to idle, to maximum power. The two SDA attachment conditions used were fully tight and loose. The newly developed SDA health algorithm described herein uses cross correlation pattern recognition to discriminate a healthy from a faulty SDA. The VIPR test results demonstrate for the first time the robustness of the SDA in an engine environment characterized by high vibration levels.

  16. Development and assessment of molecular diagnostic tests for 15 enteropathogens causing childhood diarrhoea: a multicentre study.

    Science.gov (United States)

    Liu, Jie; Kabir, Furqan; Manneh, Jainaba; Lertsethtakarn, Paphavee; Begum, Sharmin; Gratz, Jean; Becker, Steve M; Operario, Darwin J; Taniuchi, Mami; Janaki, Lalitha; Platts-Mills, James A; Haverstick, Doris M; Kabir, Mamun; Sobuz, Shihab U; Nakjarung, Kaewkanya; Sakpaisal, Pimmada; Silapong, Sasikorn; Bodhidatta, Ladaporn; Qureshi, Shahida; Kalam, Adil; Saidi, Queen; Swai, Ndealilia; Mujaga, Buliga; Maro, Athanasia; Kwambana, Brenda; Dione, Michel; Antonio, Martin; Kibiki, Gibson; Mason, Carl J; Haque, Rashidul; Iqbal, Najeeha; Zaidi, Anita K M; Houpt, Eric R

    2014-08-01

    Childhood diarrhoea can be caused by many pathogens that are difficult to assay in the laboratory. Molecular diagnostic techniques provide a uniform method to detect and quantify candidate enteropathogens. We aimed to develop and assess molecular tests for identification of enteropathogens and their association with disease. We developed and assessed molecular diagnostic tests for 15 enteropathogens across three platforms-PCR-Luminex, multiplex real-time PCR, and TaqMan array card-at five laboratories worldwide. We judged the analytical and clinical performance of these molecular techniques against comparator methods (bacterial culture, ELISA, and PCR) using 867 diarrhoeal and 619 non-diarrhoeal stool specimens. We also measured molecular quantities of pathogens to predict the association with diarrhoea, by univariate logistic regression analysis. The molecular tests showed very good analytical and clinical performance at all five laboratories. Comparator methods had limited sensitivity compared with the molecular techniques (20-85% depending on the target) but good specificity (median 97·3%, IQR 96·5-98·9; mean 95·2%, SD 9·1). Positive samples by comparator methods usually had higher molecular quantities of pathogens than did negative samples, across almost all platforms and for most pathogens (pMolecular diagnostic tests can be implemented successfully and with fidelity across laboratories around the world. In the case of diarrhoea, these techniques can detect pathogens with high sensitivity and ascribe diarrhoeal associations based on quantification, including in mixed infections, providing rich and unprecedented measurements of infectious causes. Bill & Melinda Gates Foundation Next Generation Molecular Diagnostics Project. Copyright © 2014 Elsevier Ltd. All rights reserved.

  17. Decision making about healthcare-related tests and diagnostic test strategies. Paper 2: a review of methodological and practical challenges

    NARCIS (Netherlands)

    Mustafa, Reem A.; Wiercioch, Wojtek; Cheung, Adrienne; Prediger, Barbara; Brozek, Jan; Bossuyt, Patrick; Garg, Amit X.; Lelgemann, Monika; Büehler, Diedrich; Schünemann, Holger J.

    2017-01-01

    Objectives: In this first of a series of five articles, we provide an overview of how and why healthcare-related tests and diagnostic strategies are currently applied. We also describe how our findings can be integrated with existing frameworks for making decisions that guide the use of

  18. The diagnostic accuracy of a single CEA blood test in detecting colorectal cancer recurrence: Results from the FACS trial.

    Directory of Open Access Journals (Sweden)

    Bethany Shinkins

    Full Text Available To evaluate the diagnostic accuracy of a single CEA (carcinoembryonic antigen blood test in detecting colorectal cancer recurrence.Patients who have undergone curative resection for primary colorectal cancer are typically followed up with scheduled CEA testing for 5 years. Decisions to investigate further (usually by CT imaging are based on single test results, reflecting international guidelines.A secondary analysis was undertaken of data from the FACS trial (two arms included CEA testing. The composite reference standard applied included CT-CAP imaging, clinical assessment and colonoscopy. Accuracy in detecting recurrence was evaluated in terms of sensitivity, specificity, likelihood ratios, predictive values, time-dependent area under the ROC curves, and operational performance when used prospectively in clinical practice are reported.Of 582 patients, 104 (17.9% developed recurrence during the 5 year follow-up period. Applying the recommended threshold of 5μg/L achieves at best 50.0% sensitivity (95% CI: 40.1-59.9%; in prospective use in clinical practice it would lead to 56 missed recurrences (53.8%; 95% CI: 44.2-64.4% and 89 false alarms (56.7% of 157 patients referred for investigation. Applying a lower threshold of 2.5μg/L would reduce the number of missed recurrences to 36.5% (95% CI: 26.5-46.5% but would increase the false alarms to 84.2% (924/1097 referred. Some patients are more prone to false alarms than others-at the 5μg/L threshold, the 89 episodes of unnecessary investigation were clustered in 29 individuals.Our results demonstrated very low sensitivity for CEA, bringing to question whether it could ever be used as an independent triage test. It is not feasible to improve the diagnostic performance of a single test result by reducing the recommended action threshold because of the workload and false alarms generated. Current national and international guidelines merit re-evaluation and options to improve performance, such as

  19. Diagnostic tests and algorithms used in the investigation of haematuria: systematic reviews and economic evaluation.

    Science.gov (United States)

    Rodgers, M; Nixon, J; Hempel, S; Aho, T; Kelly, J; Neal, D; Duffy, S; Ritchie, G; Kleijnen, J; Westwood, M

    2006-06-01

    To determine the most effective diagnostic strategy for the investigation of microscopic and macroscopic haematuria in adults. Electronic databases from inception to October 2003, updated in August 2004. A systematic review was undertaken according to published guidelines. Decision analytic modelling was undertaken, based on the findings of the review, expert opinion and additional information from the literature, to assess the relative cost-effectiveness of plausible alternative tests that are part of diagnostic algorithms for haematuria. A total of 118 studies met the inclusion criteria. No studies that evaluated the effectiveness of diagnostic algorithms for haematuria or the effectiveness of screening for haematuria or investigating its underlying cause were identified. Eighteen out of 19 identified studies evaluated dipstick tests and data from these suggested that these are moderately useful in establishing the presence of, but cannot be used to rule out, haematuria. Six studies using haematuria as a test for the presence of a disease indicated that the detection of microhaematuria cannot alone be considered a useful test either to rule in or rule out the presence of a significant underlying pathology (urinary calculi or bladder cancer). Forty-eight of 80 studies addressed methods to localise the source of bleeding (renal or lower urinary tract). The methods and thresholds described in these studies varied greatly, precluding any estimate of a 'best performance' threshold that could be applied across patient groups. However, studies of red blood cell morphology that used a cut-off value of 80% dysmorphic cells for glomerular disease reported consistently high specificities (potentially useful in ruling in a renal cause for haematuria). The reported sensitivities were generally low. Twenty-eight studies included data on the accuracy of laboratory tests (tumour markers, cytology) for the diagnosis of bladder cancer. The majority of tumour marker studies

  20. Veterinary Molecular Diagnostics

    NARCIS (Netherlands)

    Roest, H.I.J.; Engelsma, M.Y.; Weesendorp, E.; Bossers, A.; Elbers, A.R.W.

    2017-01-01

    In veterinary molecular diagnostics, samples originating from animals are tested. Developments in the farm animals sector and in our societal attitude towards pet animals have resulted in an increased demand for fast and reliable diagnostic techniques. Molecular diagnostics perfectly matches this

  1. The relation between math self-concept, test and math anxiety, achievement motivation and math achievement in 12 to 14-year-old typically developing adolescents

    NARCIS (Netherlands)

    Timmerman, H.L.; Toll, S.W.M.; van Luit, J.E.H.

    2017-01-01

    :This study examines the relation between math self-concept, test and math anxiety, achievement motivation, and math achievement in typically developing 12 to 14-year-old adolescents (N = 108) from a school for secondary education in the Netherlands. Data was obtained using a math speed test,

  2. Recent Progress in the Development of Diagnostic Tests for Malaria.

    Science.gov (United States)

    Krampa, Francis D; Aniweh, Yaw; Awandare, Gordon A; Kanyong, Prosper

    2017-09-19

    The impact of malaria on global health has continually prompted the need to develop effective diagnostic strategies. In malaria endemic regions, routine diagnosis is hampered by technical and infrastructural challenges to laboratories. These laboratories lack standard facilities, expertise or diagnostic supplies; thus, therapy is administered based on clinical or self-diagnosis. There is the need for accurate diagnosis of malaria due to the continuous increase in the cost of medication, and the emergence and spread of drug resistant strains. However, the widely utilized Giemsa-stained microscopy and immunochromatographic tests for malaria are liable to several drawbacks, including inadequate sensitivity and false-positive outcomes. Alternative methods that offer improvements in performance are either expensive, have longer turnaround time or require a level of expertise that makes them unsuitable for point-of-care (POC) applications. These gaps necessitate exploration of more efficient detection techniques with the potential of POC applications, especially in resource-limited settings. This minireview discusses some of the recent trends and new approaches that are seeking to improve the clinical diagnosis of malaria.

  3. Recent Progress in the Development of Diagnostic Tests for Malaria

    Directory of Open Access Journals (Sweden)

    Francis D. Krampa

    2017-09-01

    Full Text Available The impact of malaria on global health has continually prompted the need to develop effective diagnostic strategies. In malaria endemic regions, routine diagnosis is hampered by technical and infrastructural challenges to laboratories. These laboratories lack standard facilities, expertise or diagnostic supplies; thus, therapy is administered based on clinical or self-diagnosis. There is the need for accurate diagnosis of malaria due to the continuous increase in the cost of medication, and the emergence and spread of drug resistant strains. However, the widely utilized Giemsa-stained microscopy and immunochromatographic tests for malaria are liable to several drawbacks, including inadequate sensitivity and false-positive outcomes. Alternative methods that offer improvements in performance are either expensive, have longer turnaround time or require a level of expertise that makes them unsuitable for point-of-care (POC applications. These gaps necessitate exploration of more efficient detection techniques with the potential of POC applications, especially in resource-limited settings. This minireview discusses some of the recent trends and new approaches that are seeking to improve the clinical diagnosis of malaria.

  4. Surface enhanced Raman spectroscopy (SERS for in vitro diagnostic testing at the point of care

    Directory of Open Access Journals (Sweden)

    Marks Haley

    2017-06-01

    Full Text Available Point-of-care (POC device development is a growing field that aims to develop low-cost, rapid, sensitive in-vitro diagnostic testing platforms that are portable, self-contained, and can be used anywhere – from modern clinics to remote and low resource areas. In this review, surface enhanced Raman spectroscopy (SERS is discussed as a solution to facilitating the translation of bioanalytical sensing to the POC. The potential for SERS to meet the widely accepted “ASSURED” (Affordable, Sensitive, Specific, User-friendly, Rapid, Equipment-free, and Deliverable criterion provided by the World Health Organization is discussed based on recent advances in SERS in vitro assay development. As SERS provides attractive characteristics for multiplexed sensing at low concentration limits with a high degree of specificity, it holds great promise for enhancing current efforts in rapid diagnostic testing. In outlining the progression of SERS techniques over the past years combined with recent developments in smart nanomaterials, high-throughput microfluidics, and low-cost paper diagnostics, an extensive number of new possibilities show potential for translating SERS biosensors to the POC.

  5. Surface enhanced Raman spectroscopy (SERS) for in vitro diagnostic testing at the point of care

    Science.gov (United States)

    Marks, Haley; Schechinger, Monika; Garza, Javier; Locke, Andrea; Coté, Gerard

    2017-06-01

    Point-of-care (POC) device development is a growing field that aims to develop low-cost, rapid, sensitive in-vitro diagnostic testing platforms that are portable, self-contained, and can be used anywhere - from modern clinics to remote and low resource areas. In this review, surface enhanced Raman spectroscopy (SERS) is discussed as a solution to facilitating the translation of bioanalytical sensing to the POC. The potential for SERS to meet the widely accepted "ASSURED" (Affordable, Sensitive, Specific, User-friendly, Rapid, Equipment-free, and Deliverable) criterion provided by the World Health Organization is discussed based on recent advances in SERS in vitro assay development. As SERS provides attractive characteristics for multiplexed sensing at low concentration limits with a high degree of specificity, it holds great promise for enhancing current efforts in rapid diagnostic testing. In outlining the progression of SERS techniques over the past years combined with recent developments in smart nanomaterials, high-throughput microfluidics, and low-cost paper diagnostics, an extensive number of new possibilities show potential for translating SERS biosensors to the POC.

  6. Progeria Research Foundation Diagnostic Testing Program

    Science.gov (United States)

    ... Share the DVD Meet the Kids in the Movie Bring LATS to the classroom! Close News/Events ... this could severely affect their research results and interpretation. Through the PRF Diagnostics Program, each cell line ...

  7. Characteristics of diagnostic tests used in the 2002 low-pathogenicity avian influenza H7N2 outbreak in Virginia.

    Science.gov (United States)

    Elvinger, François; Akey, Bruce L; Senne, Dennis A; Pierson, F William; Porter-Spalding, Barbara A; Spackman, Erica; Suarez, David L

    2007-07-01

    An outbreak of low-pathogenicity avian influenza (LPAI) H7N2 occurred in 2002 in the Shenandoah Valley, a high-density poultry production region in Virginia. Infected flocks were identified through a combination of observation of clinical signs and laboratory diagnostic tests designed to detect avian influenza (AI) antibodies, virus, or H7-specific RNA. In this report, fitness for purpose of 3 virus/RNA detection assays used during the outbreak was examined: 1) antigen capture enzyme immunoassay (AC-EIA), 2) real-time reverse transcription polymerase chain reaction (RRT-PCR), and 3) virus isolation (VI). Results from testing 762 turkey and 2,216 chicken tracheal swab pooled specimens were analyzed to determine diagnostic sensitivities and specificities of these tests under field conditions using Bayesian techniques for validation of diagnostic tests in the absence of a "gold standard." Diagnostic sensitivities (with 95% probability intervals) in turkeys of AC-EIA and RRT-PCR, in reference to VI, were 65.9 (50.6; 81.3)% and 85.1 (71.9; 95.7)% and of VI 92.9 (78.0; 98.8)% in reference to AC-EIA or 88.7 (76.0; 97.2)% in reference to RRT-PCR; in chickens, diagnostic sensitivities were 75.1 (45.6; 94.2)%, 86.3 (65.9; 97.1)%, and 86.2 (65.8; 97.1)% or 86.3 (66.4; 97.2)%, respectively. Specificities were 99.1 (97.9; 99.8)%, 98.9 (98.0; 99.5)%, and 98.6 (97.4; 99.4)% or 98.8 (97.8; 99.5)% in turkeys and between 99.25% and 99.27% with probability intervals of approximately +/-0.4% for all tests in chickens. Simultaneous use of AC-EIA and RRT-PCR contributed significantly to the rapid control of the outbreak, but the AI RRT-PCR assay with >85% sensitivity and approximately 99% specificity, combined with relatively low cost and fast turnaround, could be used as the sole diagnostic test in outbreaks of LPAI.

  8. The Impact of Time-Series Diagnostic Tests on the Writing Ability of Iranian EFL Learners

    Science.gov (United States)

    Atashgahi, Bahareh Molazem

    2014-01-01

    This study aimed to show whether administering a battery of time-series diagnostic tests (screening) has any impact on Iranian EFL learners' writing ability. The study was conducted on the intermediate EFL learners at Islamic Azad University North Tehran branch. The researcher administered a homogenizing test in order to exclude the exceptional…

  9. Diagnostic testing for celiac disease among patients with abdominal symptoms: a systematic review.

    Science.gov (United States)

    van der Windt, Daniëlle A W M; Jellema, Petra; Mulder, Chris J; Kneepkens, C M Frank; van der Horst, Henriëtte E

    2010-05-05

    The symptoms and consequences of celiac disease usually resolve with a lifelong gluten-free diet. However, clinical presentation is variable and most patients presenting with abdominal symptoms in primary care will not have celiac disease and unnecessary diagnostic testing should be avoided. To summarize evidence on the performance of diagnostic tests for identifying celiac disease in adults presenting with abdominal symptoms in primary care or similar settings. A literature search via MEDLINE (beginning in January 1966) and EMBASE (beginning in January 1947) through December 2009 and a manual search of references for additional relevant studies. Diagnostic studies were selected if they had a cohort or nested case-control design, enrolled adults presenting with nonacute abdominal symptoms, the prevalence of celiac disease was 15% or less, and the tests used included gastrointestinal symptoms or serum antibody tests. Quality assessment using the Quality Assessment of Diagnostic Accuracy Studies tool and data extraction were performed by 2 reviewers independently. Sensitivities and specificities were calculated for each study and pooled estimates were computed using bivariate analysis if there was clinical and statistical homogeneity. Sixteen studies were included in the review (N = 6085 patients). The performance of abdominal symptoms varied widely. The sensitivity of diarrhea, for example, ranged from 0.27 to 0.86 and specificity from 0.21 to 0.86. Pooled estimates for IgA antiendomysial antibodies (8 studies) were 0.90 (95% confidence interval [CI], 0.80-0.95) for sensitivity and 0.99 (95% CI, 0.98-1.00) for specificity (positive likelihood ratio [LR] of 171 and negative LR of 0.11). Pooled estimates for IgA antitissue transglutaminase antibodies (7 studies) were 0.89 (95% CI, 0.82-0.94) and 0.98 (95% CI, 0.95-0.99), respectively (positive LR of 37.7 and negative LR of 0.11). The IgA and IgG antigliadin antibodies showed variable results, especially for

  10. Shoulder pain in primary care: diagnostic accuracy of clinical examination tests for non-traumatic acromioclavicular joint pain

    Science.gov (United States)

    2013-01-01

    Background Despite numerous methodological flaws in previous study designs and the lack of validation in primary care populations, clinical tests for identifying acromioclavicular joint (ACJ) pain are widely utilised without concern for such issues. The aim of this study was to estimate the diagnostic accuracy of traditional ACJ tests and to compare their accuracy with other clinical examination features for identifying a predominant ACJ pain source in a primary care cohort. Methods Consecutive patients with shoulder pain were recruited prospectively from primary health care clinics. Following a standardised clinical examination and diagnostic injection into the subacromial bursa, all participants received a fluoroscopically guided diagnostic block of 1% lidocaine hydrochloride (XylocaineTM) into the ACJ. Diagnostic accuracy statistics including sensitivity, specificity, predictive values, positive and negative likelihood ratios (LR+ and LR-) were calculated for traditional ACJ tests (Active Compression/O’Brien’s test, cross-body adduction, localised ACJ tenderness and Hawkins-Kennedy test), and for individual and combinations of clinical examination variables that were associated with a positive anaesthetic response (PAR) (P≤0.05) defined as 80% or more reduction in post-injection pain intensity during provocative clinical tests. Results Twenty two of 153 participants (14%) reported an 80% PAR. None of the traditional ACJ tests were associated with an 80% PAR (P0.05). Five clinical examination variables (repetitive mechanism of pain onset, no referred pain below the elbow, thickened or swollen ACJ, no symptom provocation during passive glenohumeral abduction and external rotation) were associated with an 80% PAR (P<0.05) and demonstrated an ability to accurately discriminate between an PAR and NAR (AUC 0.791; 95% CI 0.702, 0.880; P<0.001). Less than two positive clinical features resulted in 96% sensitivity (95% CI 0.78, 0.99) and a LR- 0.09 (95% CI 0.02, 0

  11. Achievement Goals and Discrete Achievement Emotions: A Theoretical Model and Prospective Test

    Science.gov (United States)

    Pekrun, Reinhard; Elliot, Andrew J.; Maier, Markus A.

    2006-01-01

    A theoretical model linking achievement goals to discrete achievement emotions is proposed. The model posits relations between the goals of the trichotomous achievement goal framework and 8 commonly experienced achievement emotions organized in a 2 (activity/outcome focus) x 2 (positive/negative valence) taxonomy. Two prospective studies tested…

  12. Appropriate targeting of artemisinin-based combination therapy by community health workers using malaria rapid diagnostic tests

    DEFF Research Database (Denmark)

    Ndyomugyenyi, Richard; Magnussen, Pascal; Lal, Sham

    2016-01-01

    OBJECTIVE: To compare the impact of malaria rapid diagnostic tests (mRDTs), used by community health workers (CHWs), on the proportion of children ...-randomized trials were conducted in two contrasting areas of moderate-to-high and low malaria transmission in rural Uganda. Each trial examined the effectiveness of mRDTs in the management of malaria and targeting of ACTs by CHWs comparing two diagnostic approaches: (i) presumptive clinical diagnosis of malaria...

  13. Rapid antigen detection test for respiratory syncytial virus diagnosis as a diagnostic tool.

    Science.gov (United States)

    Mesquita, Flávio da Silva; Oliveira, Danielle Bruna Leal de; Crema, Daniela; Pinez, Célia Miranda Nunes; Colmanetti, Thaís Cristina; Thomazelli, Luciano Matsumia; Gilio, Alfredo Elias; Vieira, Sandra Elisabeth; Martinez, Marina Baquerizo; Botosso, Viviane Fongaro; Durigon, Edison Luiz

    The aim of this study was to evaluate the QuickVue ® RSV Test Kit (QUIDEL Corp, CA, USA) as a screening tool for respiratory syncytial virus in children with acute respiratory disease in comparison with the indirect immunofluorescence assay as gold standard. In Brazil, rapid antigen detection tests for respiratory syncytial virus are not routinely utilized as a diagnostic tool, except for the diagnosis of dengue and influenza. The authors retrospectively analyzed 486 nasopharyngeal aspirate samples from children under age 5 with acute respiratory infection, between December 2013 and August 2014, the samples were analyzed by indirect immunofluorescence assay and QuickVue ® RSV Test kit. Samples with discordant results were analyzed by real time PCR and nucleotide sequencing. From 313 positive samples by immunofluorescence assays, 282 (90%) were also positive by the rapid antigen detection test, two were positive only by rapid antigen detection test, 33 were positive only by immunofluorescence assays, and 171 were positive by both methods. The 35 samples with discordant results were analyzed by real time PCR; the two samples positive only by rapid antigen detection test and the five positive only by immunofluorescence assays were also positive by real time PCR. There was no relation between the negativity by QuickVue ® RSV Test and viral load or specific strain. The QuickVue ® RSV Test showed sensitivity of 90%, specificity of 98.8%, predictive positive value of 99.3%, and negative predictive value of 94.6%, with accuracy of 93.2% and agreement κ index of 0.85 in comparison to immunofluorescence assay. This study demonstrated that the QuickVue ® RSV Test Kit can be effective in early detection of Respiratory syncytial virus in nasopharyngeal aspirate and is reliable for use as a diagnostic tool in pediatrics. Copyright © 2016 Sociedade Brasileira de Pediatria. Published by Elsevier Editora Ltda. All rights reserved.

  14. Rapid antigen detection test for respiratory syncytial virus diagnosis as a diagnostic tool,

    Directory of Open Access Journals (Sweden)

    Flávio da Silva Mesquita

    Full Text Available Abstract Objective: The aim of this study was to evaluate the QuickVue® RSV Test Kit (QUIDEL Corp, CA, USA as a screening tool for respiratory syncytial virus in children with acute respiratory disease in comparison with the indirect immunofluorescence assay as gold standard. In Brazil, rapid antigen detection tests for respiratory syncytial virus are not routinely utilized as a diagnostic tool, except for the diagnosis of dengue and influenza. Methods: The authors retrospectively analyzed 486 nasopharyngeal aspirate samples from children under age 5 with acute respiratory infection, between December 2013 and August 2014, the samples were analyzed by indirect immunofluorescence assay and QuickVue® RSV Test kit. Samples with discordant results were analyzed by real time PCR and nucleotide sequencing. Results: From 313 positive samples by immunofluorescence assays, 282 (90% were also positive by the rapid antigen detection test, two were positive only by rapid antigen detection test, 33 were positive only by immunofluorescence assays, and 171 were positive by both methods. The 35 samples with discordant results were analyzed by real time PCR; the two samples positive only by rapid antigen detection test and the five positive only by immunofluorescence assays were also positive by real time PCR. There was no relation between the negativity by QuickVue® RSV Test and viral load or specific strain. The QuickVue® RSV Test showed sensitivity of 90%, specificity of 98.8%, predictive positive value of 99.3%, and negative predictive value of 94.6%, with accuracy of 93.2% and agreement κ index of 0.85 in comparison to immunofluorescence assay. Conclusions: This study demonstrated that the QuickVue® RSV Test Kit can be effective in early detection of Respiratory syncytial virus in nasopharyngeal aspirate and is reliable for use as a diagnostic tool in pediatrics.

  15. Confirmatory Tests for the Diagnosis of Primary Aldosteronism: A Prospective Diagnostic Accuracy Study.

    Science.gov (United States)

    Song, Ying; Yang, Shumin; He, Wenwen; Hu, Jinbo; Cheng, Qingfeng; Wang, Yue; Luo, Ting; Ma, Linqiang; Zhen, Qianna; Zhang, Suhua; Mei, Mei; Wang, Zhihong; Qing, Hua; Bruemmer, Dennis; Peng, Bin; Li, Qifu

    2018-01-01

    The diagnosis of primary aldosteronism typically requires at least one confirmatory test. The fludrocortisone suppression test is generally accepted as a reliable confirmatory test, but it is cumbersome. Evidence from accuracy studies of the saline infusion test (SIT) and the captopril challenge test (CCT) has provided conflicting results. This prospective study aimed to evaluate the diagnostic accuracy of the SIT and CCT using fludrocortisone suppression test as the reference standard. One hundred thirty-five patients diagnosed with primary aldosteronism and 101 patients diagnosed with essential hypertension who completed the 3 confirmatory tests were included for the diagnostic accuracy analysis. The areas under the receiver-operator characteristics curves of the CCT and SIT were 0.96 (95% confidence interval [CI], 0.92-0.98) and 0.96 (95% CI, 0.92-0.98), respectively, using post-test plasma aldosterone concentration (PAC) for diagnosis. However, the areas under the receiver-operator characteristics curves of the CCT decreased to 0.71 (95% CI, 0.65-0.77) when the PAC suppression percentage was used to diagnose primary aldosteronism. The optimal cutoff of PAC post-CCT was set at 11 ng/dL, resulting in a sensitivity of 0.90 (95% CI, 0.84-0.95) and a specificity of 0.90 (95% CI, 0.83-0.95), which were not significantly different from those of SIT (with PAC post-SIT set at 8 ng/dL, sensitivity: 0.85 [95% CI, 0.78-0.91], P =0.192; specificity: 0.92 [95% CI, 0.85-0.97], P =0.551). In conclusion, both CCT and SIT are accurate alternatives to the more complex fludrocortisone suppression test. Because CCT is safe and much easier to perform, it may serve as a more feasible alternative. When interpreting the results of CCT, PAC post-CCT is highly recommended. © 2017 American Heart Association, Inc.

  16. Effects on costs of frontline diagnostic evaluation in patients suspected of angina: coronary computed tomography angiography vs. conventional ischaemia testing

    DEFF Research Database (Denmark)

    Nielsen, Lene H; Olsen, Jens; Markenvard, John

    2013-01-01

    group. The mean (SD) total costs per patient at the end of thefollow-up were 14% lower in the CTA group than in the ex-test group, € 1510 (3474) vs. €1777 (3746) (P = 0.03). CONCLUSION: Diagnostic assessment of symptomatic patients with a low-intermediate probability of CAD by CTA incurred lower costs......AIMS: The aim of this study was to investigate in patients with stable angina the effects on costs of frontline diagnostics by exercise-stress testing (ex-test) vs. coronary computed tomography angiography (CTA). METHODS AND RESULTS: In two coronary units at Lillebaelt Hospital, Denmark, 498...... patients were identified in whom either ex-test (n = 247) or CTA (n = 251) were applied as the frontline diagnostic strategy in symptomatic patients with a low-intermediate pre-test probability of coronary artery disease (CAD). During 12 months of follow-up, death, myocardial infarction and costs...

  17. The architecture of diagnostic research

    DEFF Research Database (Denmark)

    Colli, Agostino; Fraquelli, Mirella; Casazza, Giovanni

    2014-01-01

    The diagnostic research process can be divided into five phases, designed to establish the clinical utility of a new diagnostic test - the index test. The aim of the present review is to illustrate the study designs that are appropriate for each diagnostic phase, using clinical examples regarding...

  18. Estimation of diagnostic performance of dementia screening tests: Mini-Mental State Examination, Mini-Cog, Clock Drawing test and Ascertain Dementia 8 questionnaire.

    Science.gov (United States)

    Yang, Li; Yan, Jing; Jin, Xiaoqing; Jin, Yu; Yu, Wei; Xu, Shanhu; Wu, Haibin; Xu, Ying; Liu, Caixia

    2017-05-09

    Dementia is one of the leading causes of dependence in the elderly. This study was conducted to estimate diagnostic performance of dementia screening tests including Mini-Mental State Examination (MMSE), Mini-Cog, Clock Drawing Test (CDT) and Ascertain Dementia 8 questionnaire (AD8) by Bayesian models. A total of 2015 participants aged 65 years or more in eastern China were enrolled. The four screening tests were administered and scored by specifically trained psychiatrists. The prior information of sensitivity and specificity of every screening test was updated via Bayes' theorem to a posterior distribution. Then the results were compared with the estimation based on National Institute of Aging-Alzheimer's Association criteria (NIA-AA). The diagnostic characteristics of Mini-Cog, including sensitivity, specificity, PPV, NPV, especially the Youden index, performed well, even better than the combinations of several screening tests. The Mini-Cog with excellent screening characteristics, spending less time, could be considered to be used as a screening test to help to screen patients with cognitive impairment or dementia early. And Bayesian method was shown to be a suitable tool for evaluating dementia screening tests. The Mini-Cog with excellent screening characteristics, spending less time, could be considered to be used as a screening test to help to screen patients with cognitive impairment or dementia early. And Bayesian method was shown to be a suitable tool for evaluating dementia screening tests.

  19. Development of advanced diagnostics for characterization of burning droplets in microgravity

    Science.gov (United States)

    Sankar, Subramanian; Buermann, Dale H.; Bachalo, William D.

    1995-01-01

    Diagnostic techniques currently used for microgravity research are generally not as advanced as those used in earth based gravity experiments. Diagnostic techniques for measuring the instantaneous radial temperature profile (or temperature gradients) within the burning droplet do not exist. Over the past few years, Aerometrics has been researching and developing a rainbow thermometric technique for measuring the droplet temperatures of burning droplets. This technique has recently been integrated with the phase Doppler interferometric technique to yield a diagnostic instrument that can be used to simultaneously measure the size, velocity, and temperature of burning droplets in complex spray flames. Also, the rainbow thermometric technique has been recently integrated with a point-diffraction interferometric technique for measuring the instantaneous gas phase temperature field surrounding a burning droplet. These research programs, apart from being very successful, have also helped us identify other innovative techniques for the characterization of burning droplets. For example, new techniques have been identified for measuring the instantaneous regression rate of burning droplets. Also, there is the possibility of extracting the instantaneous radial temperature distribution or the temperature gradients within a droplet during transient heating. What is important is that these diagnostic techniques have the potential for making use of inexpensive, light-weight, and rugged devices such as diode lasers and linear CCD arrays. As a result, they can be easily packaged for incorporation into microgravity drop-test and flight-test facilities. Furthermore, with the use of linear CCD arrays, data rates as high as 10-100 kHz can be easily achieved. This data rate is orders of magnitude higher than what is currently achievable. In this research and development program, a compact and rugged diagnostic system will be developed that can be used to measure instantaneous fuel

  20. Predicting Examination Performance Using an Expanded Integrated Hierarchical Model of Test Emotions and Achievement Goals

    Science.gov (United States)

    Putwain, Dave; Deveney, Carolyn

    2009-01-01

    The aim of this study was to examine an expanded integrative hierarchical model of test emotions and achievement goal orientations in predicting the examination performance of undergraduate students. Achievement goals were theorised as mediating the relationship between test emotions and performance. 120 undergraduate students completed…

  1. Application of diagnostic tests for mycoplasmal infections of desert and gopher tortoises with management recommendations

    Science.gov (United States)

    Brown, D.R.; Schumacher, Isabella M.; Mclaughlin, Grace S.; Wendland, L.D.; Brown, Mary E.; Klein, P.A.; Jacobson, E.R.

    2002-01-01

    Mycoplasmosis is a transmissible upper respiratory tract disease that has affected plans for management and conservation of wild desert and gopher tortoises in the United States. Although impact of mycoplasmosis on populations of desert and gopher tortoises is unknown, increased prevalence of seropositive animals as well as field observations of clinically ill tortoises have occurred in association with declining populations. In order to help in the identification of potentially infected animals, three tests have been developed to diagnose mycoplasmal infections of tortoises: 1) direct mycoplasmal culture; 2) detection of mycolplasmal chromosomal DNA by polymerase chain reaction (PCR); and 3) detection of anti-Mycoplasma antibodies in tortoise plasma by enzyme-linked immunosorbent assay (ELISA). Each test provides different, complementary information that collectively can be used to define tortoise mycoplasmal infection status. The types of samples required, the predictive value, interpretation, and cost vary among tests. These assays have been used for epidemiological surveys and in decision making for relocation, repatriation, or captive management of tortoises to minimize the risk of outbreaks of mycoplasmal respiratory disease and spread of the causative agent of this disease. Certain features of mycoplasmal infections of tortoises and other animals create a diagnostic dilemma. Multiple Mycoplasma species can cause respiratory disease with identical clinical presentations. Further, individual strains of a given species may vary with respect to their virulence potential, and some species may be commensals rather than pathogens. Current diagnostic tests may not differentiate among mycoplasmal species or strains or permit determination of pathogenicity of individual isolates. Thus, the information provided by testing is not a simple 'positive' vs. 'negative' issue. While these tests provide much needed information on the exposure of tortoise populations to

  2. Large-Scale Academic Achievement Testing of Deaf and Hard-of-Hearing Students: Past, Present, and Future

    Science.gov (United States)

    Qi, Sen; Mitchell, Ross E.

    2012-01-01

    The first large-scale, nationwide academic achievement testing program using Stanford Achievement Test (Stanford) for deaf and hard-of-hearing children in the United States started in 1969. Over the past three decades, the Stanford has served as a benchmark in the field of deaf education for assessing student academic achievement. However, the…

  3. Implementation of the International Code of Practice on Dosimetry in Diagnostic Radiology (TRS 457): Review of Test Results

    International Nuclear Information System (INIS)

    2011-01-01

    In 2007, the IAEA published Dosimetry in Diagnostic Radiology: An International Code of Practice (IAEA Technical Reports Series No. 457). This publication recommends procedures for calibration and dosimetric measurement for the attainment of standardized dosimetry. It also addresses requirements both in standards dosimetry laboratories, especially Secondary Standards Dosimetry Laboratories (SSDLs), and in clinical centres for radiology, as found in most hospitals. The implementation of TRS No. 457 decreases the uncertainty in the dosimetry of diagnostic radiology beams and provides Member States with a unified and consistent framework for dosimetry in diagnostic radiology, which previously did not exist. A coordinated research project (CRP E2.10.06) was established in order to provide practical guidance to professionals at SSDLs and to clinical medical physicists on the implementation of TRS No. 457. This includes the calibration of radiological dosimetry instrumentation, the dissemination of calibration coefficients to clinical centres and the establishment of dosimetric measurement processes in clinical settings. The main goals of the CRP were to: Test the procedures recommended in TRS No. 457 for calibration of radiation detectors in different types of diagnostic beams and measuring instruments for varying diagnostic X ray modalities; Test the clinical dosimetry procedures, including the use of phantoms and patient dose surveys; Report on the practical implementation of TRS No. 457 at both SSDLs and hospital sites. Testing of TRS No. 457 was performed by a group of medical physicists from hospitals and SSDLs from various institutions worldwide

  4. Quality Control in Diagnostic Radiology in the Netherlands (invited paper)

    International Nuclear Information System (INIS)

    Zoetelief, J.

    1998-01-01

    Application of the general principles of radiation protection to medical diagnostic radiology implies that each procedure using X rays or radionuclides is to be justified and optimised. Optimisation in diagnostic radiology implies that the radiation burden to the patient should be as low as possible, but compatible with the image quality necessary to obtain an adequate diagnosis or to guide treatment. Quality control of equipment is a prerequisite for achieving optimisation in diagnostic radiology. This was especially recognised for mammography as employed for breast cancer screening. Existing legislation in the Netherlands includes only a few criteria for equipment used in diagnostic radiology. In addition, the criteria are not all operational and measurement methods are lacking. Therefore, upon the initiative of the Dutch Ministry of Health, Welfare and Sports, the relevant professional societies, in collaboration with the former TNO Centre for Radiological Protection and Dosimetry, formulated eleven guidelines for quality control of equipment used in diagnostic radiology, including test procedures, test frequencies and limiting values. The implementation of quality control of equipment was included in the 1984 European Directive (84/466/Euratom) laying down basic measures for the radiation protection of persons undergoing medical examination or treatment. In the most recent European Directive on medical exposure (97/43/Euratom) the importance of quality control is stressed. In addition, the latter EC directive proposes the use of diagnostic reference levels for limiting the risks for patients undergoing diagnostic radiology. In the Netherlands preliminary reference levels for various procedures employed in diagnostic radiology are suggested. Finally, methods applied in the Netherlands for assessment of image quality are discussed. (author)

  5. Clinical review: Distinguishing constitutional delay of growth and puberty from isolated hypogonadotropic hypogonadism: critical appraisal of available diagnostic tests.

    Science.gov (United States)

    Harrington, Jennifer; Palmert, Mark R

    2012-09-01

    Determining the etiology of delayed puberty during initial evaluation can be challenging. Specifically, clinicians often cannot distinguish constitutional delay of growth and puberty (CDGP) from isolated hypogonadotropic hypogonadism (IHH), with definitive diagnosis of IHH awaiting lack of spontaneous puberty by age 18 yr. However, the ability to make a timely, correct diagnosis has important clinical implications. The aim was to describe and evaluate the literature regarding the ability of diagnostic tests to distinguish CDGP from IHH. A PubMed search was performed using key words "puberty, delayed" and "hypogonadotropic hypogonadism," and citations within retrieved articles were reviewed to identify studies that assessed the utility of basal and stimulation tests in the diagnosis of delayed puberty. Emphasis was given to a test's ability to distinguish prepubertal adolescents with CDGP from those with IHH. Basal gonadotropin and GnRH stimulation tests have limited diagnostic specificity, with overlap in gonadotropin levels between adolescents with CDGP and IHH. Stimulation tests using more potent GnRH agonists and/or human chorionic gonadotropin may have better discriminatory value, but small study size, lack of replication of diagnostic thresholds, and prolonged protocols limit clinical application. A single inhibin B level in two recent studies demonstrated good differentiation between groups. Distinguishing IHH from CDGP is an important clinical issue. Basal inhibin B may offer a simple, discriminatory test if results from recent studies are replicated. However, current literature does not allow for recommendation of any diagnostic test for routine clinical use, making this an important area for future investigation.

  6. The Impact of Time-Series Diagnostic Tests on the Writing Ability of Iranian EFL learners

    Directory of Open Access Journals (Sweden)

    Bahareh Molazem Atashgahi

    2014-02-01

    Full Text Available This study aimed to show whether administering a battery of time-series diagnostic tests (screening has any impact on Iranian EFL learners’ writing ability. The study was conducted on the intermediate EFL learners at Islamic Azad University North Tehran branch.  The researcher administered a homogenizing test in order to exclude the exceptional scores, among all the testers, only those whose scores were nearly within one standard deviation above or below the mean were selected as the participants of this study. After the assignment of the participants to the control and experimental groups- 30 students in each group- they were asked to write five-paragraph-essays on two topics. Such a pretest was given to both groups to test their initial writing ability. Once scoring of the students’ writings (five- paragraph essay was finished the two means of the groups were calculated and compared with each other through the t-test analysis. The result demonstrated that there was no statistically significant difference between those two groups regarding the variable under investigation. Four sets of diagnostic tests were given to the experimental group every two weeks and after each test both the result of the exam and suitable feedback regarding students’ errors were given to them by the teacher, while the Current-Traditional Rhetoric method was administered in the control group. In the posttest which was run after giving the treatment and placebo to experimental group and control group respectively, students took another writing test with the same characteristics in administration, topics and scoring as the one in pretest. Thereafter, the significance of the difference between the obtained means of experimental and control groups in the posttest was determined through the t-test.  The result of the t-test analysis indicated a significant difference between the two groups which consequently rejected the null hypothesis of the study. Therefore, any

  7. Diagnostic value of the proton pump inhibitor test for gastro-oesophageal reflux disease in primary care

    NARCIS (Netherlands)

    Aanen, M. C.; Weusten, B. L. A. M.; Numans, M. E.; de Wit, N. J.; Baron, A.; Smout, A. J. P. M.

    2006-01-01

    AIM: To assess the diagnostic accuracy of the proton pump inhibitor test in a primary care population as well as its additional value over reflux history, using the symptom association probability outcome during 24-h oesophageal pH recording as reference test for gastro-oesophageal reflux disease.

  8. English Language Proficiency Tests and Academic Achievement: A Study on the Malaysian University English Test as a Predictor of Technical Programme Undergraduates Academic Achievement

    Directory of Open Access Journals (Sweden)

    Nurhazlini Rahmat

    2015-02-01

    Full Text Available In the Malaysian education system, English has always played an important role. In acknowledging its importance, Malaysian University English Test (MUET has been introduced to enable continued emphasis on this role.  MUET has been made compulsory for those who wish to pursue a first degree programme in local universities. This study aims to examine the relationship between English language proficiency test (as measured by MUET bands to predict the undergraduates academic achievement (as measured by Cumulative Grade Point Average score. It also aims to determine the recommended MUET band as an entry requirement for prospective technical programme undergraduates in Universiti Putra Malaysia (UPM. The study was carried out among 225 final year undergraduates of five different faculties in UPM, namely Faculty of Engineering, Faculty of Forestry, Faculty of Biotechnology and Biomolecular, Faculty of Food Science and Technology, and Faculty of Veterinary Medicine.  The data used were obtained by administering a brief questionnaire and were quantitatively analysed using Statistical Package for Social Science (SPSS version 19.  The study revealed that there is a medium positive correlation between English language proficiency and academic achievement where students who have scored higher bands for MUET are the ones who obtained higher CGPA in their study. Based on the findings, it is recommended that UPM and other local universities make changes towards the minimum MUET entry requirement to help prospective undergraduates excel in their academic study. Keywords: English language proficiency, academic achievement, technical programme, MUET, CGPA

  9. Evaluating the Instructional Sensitivity of Four States' Student Achievement Tests

    Science.gov (United States)

    Polikoff, Morgan S.

    2016-01-01

    As state tests of student achievement are used for an increasingly wide array of high- and low-stakes purposes, evaluating their instructional sensitivity is essential. This article uses data from the Bill and Melinda Gates Foundation's Measures of Effective Project to examine the instructional sensitivity of 4 states' mathematics and English…

  10. Small-scale deflagration cylinder test with velocimetry wall-motion diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Hooks, Daniel E [Los Alamos National Laboratory; Hill, Larry G [Los Alamos National Laboratory; Pierce, Timothy H [Los Alamos National Laboratory

    2010-01-01

    Predicting the likelihood and effects of outcomes resultant from thermal initiation of explosives remains a significant challenge. For certain explosive formulations, the general outcome can be broadly predicted given knowledge of certain conditions. However, there remain unexplained violent events, and increased statistical understanding of outcomes as a function of many variables, or 'violence categorization,' is needed. Additionally, the development of an equation of state equivalent for deflagration would be very useful in predicting possible detailed event consequences using traditional hydrodynamic detonation moders. For violence categorization, it is desirable that testing be efficient, such that it is possible to statistically define outcomes reliant on the processes of initiation of deflagration, steady state deflagration, and deflagration to detonation transitions. If the test simultaneously acquires information to inform models of violent deflagration events, overall predictive capabilities for event likelihood and consequence might improve remarkably. In this paper we describe an economical scaled deflagration cylinder test. The cyclotetramethylene tetranitramine (HMX) based explosive formu1lation PBX 9501 was tested using different temperature profiles in a thick-walled copper cylindrical confiner. This test is a scaled version of a recently demonstrated deflagration cylinder test, and is similar to several other thermal explosion tests. The primary difference is the passive velocimetry diagnostic, which enables measurement of confinement vessel wall velocities at failure, regardless of the timing and location of ignition.

  11. Frequency of chest pain in primary care, diagnostic tests performed and final diagnoses.

    Science.gov (United States)

    Hoorweg, Beatrijs Bn; Willemsen, Robert Ta; Cleef, Lotte E; Boogaerts, Tom; Buntinx, Frank; Glatz, Jan Fc; Dinant, Geert Jan

    2017-11-01

    Observational study of patients with chest pain in primary care: determination of incidence, referral rate, diagnostic tests and (agreement between) working and final diagnoses. 118 general practitioners (GPs) in the Netherlands and Belgium recorded all patient contacts during  2weeks. Furthermore, patients presenting with chest pain were registered extensively. A follow-up form was filled in after 30 days. 22 294 patient contacts were registered. In 281 (1.26%), chest pain was a reason for consulting the GP (mean age for men 54.4/women 53 years). In this cohort of 281 patients, in 38.1% of patients, acute coronary syndrome (ACS) was suspected at least temporarily during consultation, 40.2% of patients were referred to secondary care and 512 diagnostic tests were performed by GPs and consulted specialists. Musculoskeletal pain was the most frequent working (26.1%) and final diagnoses (33.1%). Potentially life-threatening diseases as final diagnosis (such as myocardial infarction) accounted for 8.4% of all chest pain cases. In 23.1% of cases, a major difference between working and final diagnoses was found, in 0.7% a severe disease was initially missed by the GP. Chest pain was present in 281 patients (1.26% of all consultations). Final diagnoses were mostly non-life-threatening. Nevertheless, in 8.4% of patients with chest pain, life-threatening underlying causes were identified. This seems reflected in the magnitude and wide variety of diagnostic tests performed in these patients by GPs and specialists, in the (safe) overestimation of life-threatening diseases by GPs at initial assessment and in the high referral rate we found. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  12. Diagnostic Validity of Combining History Elements and Physical Examination Tests for Traumatic and Degenerative Symptomatic Meniscal Tears.

    Science.gov (United States)

    Décary, Simon; Fallaha, Michel; Frémont, Pierre; Martel-Pelletier, Johanne; Pelletier, Jean-Pierre; Feldman, Debbie E; Sylvestre, Marie-Pierre; Vendittoli, Pascal-André; Desmeules, François

    2017-10-27

    The current approach to the clinical diagnosis of traumatic and degenerative symptomatic meniscal tears (SMTs) proposes combining history elements and physical examination tests without systematic prescription of imaging investigations, yet the evidence to support this diagnostic approach is scarce. To assess the validity of diagnostic clusters combining history elements and physical examination tests to diagnose or exclude traumatic and degenerative SMT compared with other knee disorders. Prospective diagnostic accuracy study. Patients were recruited from 2 orthopedic clinics, 2 family medicine clinics, and from a university community. A total of 279 consecutive patients who underwent consultation for a new knee complaint. Each patient was assessed independently by 2 evaluators. History elements and standardized physical examination tests performed by a physiotherapist were compared with the reference standard: an expert physicians' composite diagnosis including a clinical examination and confirmatory magnetic resonance imaging. Participating expert physicians were orthopedic surgeons (n = 3) or sport medicine physicians (n = 2). Penalized logistic regression (least absolute shrinkage and selection operator) was used to identify history elements and physical examination tests associated with the diagnosis of SMT and recursive partitioning was used to develop diagnostic clusters. Diagnostic accuracy measures were calculated including sensitivity, specificity, positive and negative predictive values, and positive and negative likelihood ratios (LR+/-) with associated 95% confidence intervals (CIs). Eighty patients had a diagnosis of SMT (28.7%), including 35 traumatic tears and 45 degenerative tears. The combination a history of trauma during a pivot, medial knee pain location, and a positive medial joint line tenderness test was able to diagnose (LR+ = 8.9; 95% CI 6.1-13.1) or exclude (LR- = 0.10; 95% CI 0.03-0.28) a traumatic SMT. Combining a history of

  13. Large-scale academic achievement testing of deaf and hard-of-hearing students: past, present, and future.

    Science.gov (United States)

    Qi, Sen; Mitchell, Ross E

    2012-01-01

    The first large-scale, nationwide academic achievement testing program using Stanford Achievement Test (Stanford) for deaf and hard-of-hearing children in the United States started in 1969. Over the past three decades, the Stanford has served as a benchmark in the field of deaf education for assessing student academic achievement. However, the validity and reliability of using the Stanford for this special student population still require extensive scrutiny. Recent shifts in educational policy environment, which require that schools enable all children to achieve proficiency through accountability testing, warrants a close examination of the adequacy and relevance of the current large-scale testing of deaf and hard-of-hearing students. This study has three objectives: (a) it will summarize the historical data over the last three decades to indicate trends in academic achievement for this special population, (b) it will analyze the current federal laws and regulations related to educational testing and special education, thereby identifying gaps between policy and practice in the field, especially identifying the limitations of current testing programs in assessing what deaf and hard-of-hearing students know, and (c) it will offer some insights and suggestions for future testing programs for deaf and hard-of-hearing students.

  14. Epidemiology of meningitis with a negative CSF Gram stain: under-utilization of available diagnostic tests.

    Science.gov (United States)

    Nesher, L; Hadi, C M; Salazar, L; Wootton, S H; Garey, K W; Lasco, T; Luce, A M; Hasbun, R

    2016-01-01

    Meningitis with a negative cerebrospinal fluid Gram stain (CSF-GS) poses a diagnostic challenge as more than 50% of patients remain without an aetiology. The introduction of polymerase chain reaction (PCR) and arboviral serologies have increased diagnostic capabilities, yet large scale epidemiological studies evaluating their use in clinical practice are lacking. We conducted a prospective observational study in New Orleans between November 1999 and September 2008 (early era) when PCR was not widely available, and in Houston between November 2008 and June 2013 (modern era), when PCR was commonly used. Patients presenting with meningitis and negative CSF-GS were followed for 4 weeks. All investigations, PCR used, and results were recorded as they became available. In 323 patients enrolled, PCR provided the highest diagnostic yield (24·2%) but was ordered for 128 (39·6%) patients; followed by serology for arboviruses (15%) that was ordered for 100 (31%) of all patients. The yield of blood cultures was (10·3%) and that of CSF cultures was 4%; the yield for all other tests was meningitis and a negative CSF-GS, but both tests are being under-utilized.

  15. HIV rapid diagnostic testing by lay providers in a key population-led health service programme in Thailand.

    Science.gov (United States)

    Wongkanya, Rapeeporn; Pankam, Tippawan; Wolf, Shauna; Pattanachaiwit, Supanit; Jantarapakde, Jureeporn; Pengnongyang, Supabhorn; Thapwong, Prasopsuk; Udomjirasirichot, Apichat; Churattanakraisri, Yutthana; Prawepray, Nanthika; Paksornsit, Apiluk; Sitthipau, Thidadaow; Petchaithong, Sarayut; Jitsakulchaidejt, Raruay; Nookhai, Somboon; Lertpiriyasuwat, Cheewanan; Ongwandee, Sumet; Phanuphak, Praphan; Phanuphak, Nittaya

    2018-01-01

    Introduction:  Rapid diagnostic testing (RDT) for HIV has a quick turn-around time, which increases the proportion of people testing who receive their result. HIV RDT in Thailand has traditionally been performed only by medical technologists (MTs), which is a barrier to its being scaled up. We evaluated the performance of HIV RDT conducted by trained lay providers who were members of, or worked closely with, a group of men who have sex with men (MSM) and with transgender women (TG) communities, and compared it to tests conducted by MTs. Methods:  Lay providers received a 3-day intensive training course on how to perform a finger-prick blood collection and an HIV RDT as part of the Key Population-led Health Services (KPLHS) programme among MSM and TG. All the samples were tested by lay providers using Alere Determine HIV 1/2. HIV-reactive samples were confirmed by DoubleCheckGold Ultra HIV 1&2 and SD Bioline HIV 1/2. All HIV-positive and 10% of HIV-negative samples were re-tested by MTs using Serodia HIV 1/2. Results:  Of 1680 finger-prick blood samples collected and tested using HIV RDT by lay providers in six drop-in centres in Bangkok, Chiang Mai, Chonburi and Songkhla, 252 (15%) were HIV-positive. MTs re-tested these HIV-positive samples and 143 randomly selected HIV-negative samples with 100% concordant test results. Conclusion:  Lay providers in Thailand can be trained and empowered to perform HIV RDT as they were found to achieve comparable results in sample testing with MTs. Based on the task-shifting concept, this rapid HIV testing performed by lay providers as part of the KPLHS programme has great potential to enhance HIV prevention and treatment programmes among key at-risk populations.

  16. Diagnostic development and support of MHD test facilities: Technical progress report for the period January, February, March 1985

    International Nuclear Information System (INIS)

    Shepard, W.S.; Cook, R.L.

    1985-04-01

    Mississippi State University is developing diagnostic instruments for MHD power train data acquisition and for support of MHD component development test facilities. Microprocessor-controlled optical instruments, initially developed for HRSR support, are being refined, and new systems to measure temperatures and gas-seed-slag stream characteristics are being developed. To further data acquisition and analysis capabilities, the diagnostic systems are being interfaced with MHD Energy Center computers. Additionally, technical support of the diagnostic needs of the national MHD research effort is being provided

  17. Applying Diagnostics to Enhance Cable System Reliability (Cable Diagnostic Focused Initiative, Phase II)

    Energy Technology Data Exchange (ETDEWEB)

    Hartlein, Rick [Georgia Tech Research Corporation (GTRC), Atlanta, GA (United States). National Electric Energy Testing, Research and Applications Center (NEETRAC); Hampton, Nigel [Georgia Tech Research Corporation (GTRC), Atlanta, GA (United States). National Electric Energy Testing, Research and Applications Center (NEETRAC); Perkel, Josh [Georgia Tech Research Corporation (GTRC), Atlanta, GA (United States). National Electric Energy Testing, Research and Applications Center (NEETRAC); Hernandez, JC [Univ. de Los Andes, Merida (Venezuela); Elledge, Stacy [Georgia Tech Research Corporation (GTRC), Atlanta, GA (United States). National Electric Energy Testing, Research and Applications Center (NEETRAC); del Valle, Yamille [Georgia Tech Research Corporation (GTRC), Atlanta, GA (United States). National Electric Energy Testing, Research and Applications Center (NEETRAC); Grimaldo, Jose [Georgia Inst. of Technology, Atlanta, GA (United States). School of Electrical and Computer Engineering; Deku, Kodzo [Georgia Inst. of Technology, Atlanta, GA (United States). George W. Woodruff School of Mechanical Engineering

    2016-02-01

    The Cable Diagnostic Focused Initiative (CDFI) played a significant and powerful role in clarifying the concerns and understanding the benefits of performing diagnostic tests on underground power cable systems. This project focused on the medium and high voltage cable systems used in utility transmission and distribution (T&D) systems. While many of the analysis techniques and interpretations are applicable to diagnostics and cable systems outside of T&D, areas such as generating stations (nuclear, coal, wind, etc.) and other industrial environments were not the focus. Many large utilities in North America now deploy diagnostics or have changed their diagnostic testing approach as a result of this project. Previous to the CDFI, different diagnostic technology providers individually promoted their approach as the “the best” or “the only” means of detecting cable system defects.

  18. Laboratory Information Systems in Molecular Diagnostics: Why Molecular Diagnostics Data are Different.

    Science.gov (United States)

    Lee, Roy E; Henricks, Walter H; Sirintrapun, Sahussapont J

    2016-03-01

    Molecular diagnostic testing presents new challenges to information management that are yet to be sufficiently addressed by currently available information systems for the molecular laboratory. These challenges relate to unique aspects of molecular genetic testing: molecular test ordering, informed consent issues, diverse specimen types that encompass the full breadth of specimens handled by traditional anatomic and clinical pathology information systems, data structures and data elements specific to molecular testing, varied testing workflows and protocols, diverse instrument outputs, unique needs and requirements of molecular test reporting, and nuances related to the dissemination of molecular pathology test reports. By satisfactorily addressing these needs in molecular test data management, a laboratory information system designed for the unique needs of molecular diagnostics presents a compelling reason to migrate away from the current paper and spreadsheet information management that many molecular laboratories currently use. This paper reviews the issues and challenges of information management in the molecular diagnostics laboratory.

  19. Gearbox vibration diagnostic analyzer

    Science.gov (United States)

    1992-01-01

    This report describes the Gearbox Vibration Diagnostic Analyzer installed in the NASA Lewis Research Center's 500 HP Helicopter Transmission Test Stand to monitor gearbox testing. The vibration of the gearbox is analyzed using diagnostic algorithms to calculate a parameter indicating damaged components.

  20. How to diagnose neuropathic pain? The contribution from clinical examination, pain questionnaires and diagnostic tests.

    Science.gov (United States)

    La Cesa, S; Tamburin, S; Tugnoli, V; Sandrini, G; Paolucci, S; Lacerenza, M; Marchettini, P; Cruccu, G; Truini, A

    2015-12-01

    Patients with peripheral and central nervous system diseases may suffer from different types of pain, namely nociceptive, neuropathic and mixed pain. Although in some cases, the distinction between these types of pain is clinically evident, yet in some patients an accurate differential diagnosis requires dedicated clinical examination, screening questionnaires and diagnostic techniques some of which are available only in specialized pain centres. This review briefly addresses the currently agreed definitions of the different types of pain and shows how clinical examination, pain questionnaires and diagnostic tests can help the clinicians in identifying neuropathic pain.

  1. Implementation of broad screening with Ebola rapid diagnostic tests in Forécariah, Guinea

    Directory of Open Access Journals (Sweden)

    Frantz Jean Louis

    2017-03-01

    Full Text Available Background: Laboratory-enhanced surveillance is critical for rapidly detecting the potential re-emergence of Ebola virus disease. Rapid diagnostic tests (RDT for Ebola antigens could expand diagnostic capacity for Ebola virus disease. Objectives: The Guinean National Coordination for Ebola Response conducted a pilot implementation to determine the feasibility of broad screening of patients and corpses with the OraQuick® Ebola RDT. Methods: The implementation team developed protocols and trained healthcare workers to screen patients and corpses in Forécariah prefecture, Guinea, from 15 October to 30 November 2015. Data collected included number of consultations, number of fevers reported or measured, number of tests performed for patients or corpses and results of confirmatory RT-PCR testing. Data on malaria RDT results were collected for comparison. Feedback from Ebola RDT users was collected informally during supervision visits and forums. Results: There were 3738 consultations at the 15 selected healthcare facilities; 74.6% of consultations were for febrile illness. Among 2787 eligible febrile patients, 2633 were tested for malaria and 1628 OraQuick® Ebola RDTs were performed. A total of 322 OraQuick® Ebola RDTs were conducted on corpses. All Ebola tests on eligible patients were negative. Conclusions: Access to Ebola testing was expanded by the implementation of RDTs in an emergency situation. Feedback from Ebola RDT users and lessons learned will contribute to improving quality for RDT expansion.

  2. Enhancing the Usability of an Optical Reader System to Support Point-of-Care Rapid Diagnostic Testing: An Iterative Design Approach.

    Science.gov (United States)

    Hohenstein, Jess; O'Dell, Dakota; Murnane, Elizabeth L; Lu, Zhengda; Erickson, David; Gay, Geri

    2017-11-21

    In today's health care environment, increasing costs and inadequate medical resources have created a worldwide need for more affordable diagnostic tools that are also portable, fast, and easy to use. To address this issue, numerous research and commercial efforts have focused on developing rapid diagnostic technologies; however, the efficacy of existing systems has been hindered by usability problems or high production costs, making them infeasible for deployment in at-home, point-of-care (POC), or resource-limited settings. The aim of this study was to create a low-cost optical reader system that integrates with any smart device and accepts any type of rapid diagnostic test strip to provide fast and accurate data collection, sample analysis, and diagnostic result reporting. An iterative design methodology was employed by a multidisciplinary research team to engineer three versions of a portable diagnostic testing device that were evaluated for usability and overall user receptivity. Repeated design critiques and usability studies identified a number of system requirements and considerations (eg, software compatibility, biomatter contamination, and physical footprint) that we worked to incrementally incorporate into successive system variants. Our final design phase culminated in the development of Tidbit, a reader that is compatible with any Wi-Fi-enabled device and test strip format. The Tidbit includes various features that support intuitive operation, including a straightforward test strip insertion point, external indicator lights, concealed electronic components, and an asymmetric shape, which inherently signals correct device orientation. Usability testing of the Tidbit indicates high usability for potential user communities. This study presents the design process, specification, and user reception of the Tidbit, an inexpensive, easy-to-use, portable optical reader for fast, accurate quantification of rapid diagnostic test results. Usability testing suggests

  3. Operational evaluation of rapid diagnostic testing for Ebola Virus Disease in Guinean laboratories.

    Directory of Open Access Journals (Sweden)

    Amanda VanSteelandt

    Full Text Available Rapid Diagnostic Tests (RDTs for Ebola Virus Disease (EVD at the point of care have the potential to increase access and acceptability of EVD testing and the speed of patient isolation and secure burials for suspect cases. A pilot program for EVD RDTs in high risk areas of Guinea was introduced in October 2015. This paper presents concordance data between EVD RDTs and PCR testing in the field as well as an assessment of the acceptability, feasibility, and quality assurance of the RDT program.Concordance data were compiled from laboratory surveillance databases. The operational measures of the laboratory-based EVD RDT program were evaluated at all 34 sentinel sites in Guinea through: (1 a technical questionnaire filled by the lab technicians who performed the RDTs, (2 a checklist filled by the evaluator during the site visits, and (3 direct observation of the lab technicians performing the quality control test. Acceptability of the EVD RDT was good for technicians, patients, and families although many technicians (69.8% expressed concern for their safety while performing the test. The feasibility of the program was good based on average technician knowledge scores (6.6 out of 8 but basic infrastructure, equipment, and supplies were lacking. There was much room for improvement in quality assurance of the program.The implementation of new diagnostics in weak laboratory systems requires general training in quality assurance, biosafety and communication with patients in addition to specific training for the new test. Corresponding capacity building in terms of basic equipment and a long-term commitment to transfer supervision and quality improvement to national public health staff are necessary for successful implementation.

  4. [Diagnostic value of neuropsychological tests in mild cognitive impairment comorbid with Parkinson's disease].

    Science.gov (United States)

    Laskowska, Ilona; Koczorowski, Andrzej; Koziorowski, Dariusz; Gawryś, Ludwika

    2014-01-01

    Mild cognitive impairment (MCI) is present in on average one-fourth of Parkinson's disease (PD) patients with no dementia diagnosis. Only recently has PD-MCI been treated as a new diagnostic entity. In 2012, unified criteria were adopted which allow both diagnosing MCI in Parkinson's disease (PD-MCI) and further classification taking into account the profile of cognitive dysfunctions and the probability of evolution towards dementia. The diagnostic criteria were presented in the form of stipulations and guidelines assuming that diagnostic process is based on the neuropsychological assessment of the patient. The notion of MCI had been borrowed and for a couple of years had been relying on definitions developed in relation to Alzheimer's disease. For the first time, in the proposed criteria memory dysfunction is not the basis of classification. Only two categories of dysfunctions have been retained, single-domain and multiple-domain. Whether the adopted criteria will contribute to an accurate diagnosis of cognitive dysfunctions and PD-specific dementing processes remains an open question. In spite of some limitations, the presented criteria can certainly improve the efficacy of monitoring the patient's state at the same time allowing the hope for an appropriate therapy and a higher quality of life. Moreover, the unification of diagnostic criteria will be crucial in assessing usefulness ofneuropsychological test instruments as a basic method of investigating neurodegenerative processes not only in PD.

  5. Low diagnostic value of fasting and post-methionine load homocysteine tests. A study in Dutch subjects with homocysteine test indications

    NARCIS (Netherlands)

    Fokkema, M R; Dijck-Brouwer, D A J; van Doormaal, J J; Reijngoud, D J; Muskiet, F A J

    BACKGROUND: Homocysteine is a cardiovascular disease risk factor. We investigated, both in subjects with past plasma total homocysteine (tHcy) test indications and healthy adults, the diagnostic value of a fasting (tHcy) (f-tHcy) and the added value of a post-methionine-load tHcy (postload-tHcy).

  6. Diagnostic Efficacy of Modified Coagglutination Test in the Diagnosis of Human Brucellosis

    Directory of Open Access Journals (Sweden)

    Mohite S.T

    2013-07-01

    Full Text Available Background: Laboratory help is must for thediagnosis of human brucellosis due to proteanclinical manifestations. As culture is hazardous,time consuming and less sensitive, serologicaltests are preferred for the diagnosis. Aggluti-nation tests like Rose Bengal PlateTest (RBPT, Serum Agglutination tests (SAT,2-Mercaptoethanol test (2-ME that are com-monly employed for the diagnosis either lacksensitivity or specificity. Coombs test andBrucellacapt though are sensitive and specific,workout costly. Therefore, modifiedcoagglutination test was developed and its di-agnostic efficacy was evaluated. Aims and Ob-jectives: To develop modified coagglutinationtest for the diagnosis of human brucellosis andcompare it with Coombs test. Materials andMethods: Serum samples collected from 191brucellosis patients and 100 controls were sub-jected to 2-ME, Coombs test and modifiedcoagglutination test (MCOAG. Blood culturewas performed by Castaneda’s method in all thepatients. Results: Significant difference in thepositivity rate was seen between MCOAG and2-ME. The results of MCOAG were compa-rable with Coombs test. Conclusions: Modi-fied coagglutination test is a better option toCoombs test for the serodiagnosis of brucel-losis in resource constrained countries as it issensitive, specific and cost effective.

  7. More than just T₄: diagnostic testing for hyperthyroidism in cats.

    Science.gov (United States)

    Peterson, Mark E

    2013-09-01

    In older cats presenting with clinical features of hyperthyroidism, confirmation of a diagnosis of thyroid disease is usually straightforward. However, the potential for false-negative and false-positive results exists with all thyroid function tests (especially in the context of routine screening of asymptomatic cats) and leads to clinical dilemmas. For example, a high serum T₄ value may be found in a cat that lacks clinical signs of hyperthyroidism, or hyperthyroidism may be suspected in a cat with normal total T₄ concentrations. To avoid unnecessary treatment and potentially adverse effects in a euthyroid cat, thyroid function tests must always be interpreted in the light of the cat's history, clinical signs, physical examination findings and other laboratory findings. In this article the author reviews the use of commonly recommended thyroid function tests, focusing on clinical scenarios that present diagnostic difficulties. In doing so, he draws on the veterinary and comparative literature, his own clinical experience, and data, unpublished to date, obtained from a series of 100 hyperthyroid cats consecutively diagnosed at his clinic.

  8. Diagnostic utility of the glucagon stimulation test in comparison to the insulin tolerance test in patients following pituitary surgery

    DEFF Research Database (Denmark)

    Berg, Christian; Meinel, Timo; Lahner, Harald

    2009-01-01

    OBJECTIVE: The glucagon stimulation test (GST) like the insulin tolerance test (ITT) stimulates both ACTH and GH secretion. However, there are limited data with modern assays on sensitivity and specificity for GST in comparison to ITT. The aim of this study was to evaluate the diagnostic utility......). Receiver-operating characteristic (ROC) analysis was performed to identify the thresholds for GST. RESULTS: In ITT, 18/49 cases were classified as AI. ROC analysis revealed a peak cortisol value >599 nmol/l in GST for adrenal sufficiency with 100% specificity and 32% sensitivity, and a peak cortisol

  9. Cable Diagnostic Focused Initiative

    Energy Technology Data Exchange (ETDEWEB)

    Hartlein, R.A.; Hampton, R.N.

    2010-12-30

    This report summarizes an extensive effort made to understand how to effectively use the various diagnostic technologies to establish the condition of medium voltage underground cable circuits. These circuits make up an extensive portion of the electric delivery infrastructure in the United States. Much of this infrastructure is old and experiencing unacceptable failure rates. By deploying efficient diagnostic testing programs, electric utilities can replace or repair circuits that are about to fail, providing an optimal approach to improving electric system reliability. This is an intrinsically complex topic. Underground cable systems are not homogeneous. Cable circuits often contain multiple branches with different cable designs and a range of insulation materials. In addition, each insulation material ages differently as a function of time, temperature and operating environment. To complicate matters further, there are a wide variety of diagnostic technologies available for assessing the condition of cable circuits with a diversity of claims about the effectiveness of each approach. As a result, the benefits of deploying cable diagnostic testing programs have been difficult to establish, leading many utilities to avoid the their use altogether. This project was designed to help address these issues. The information provided is the result of a collaborative effort between Georgia Tech NEETRAC staff, Georgia Tech academic faculty, electric utility industry participants, as well as cable system diagnostic testing service providers and test equipment providers. Report topics include: •How cable systems age and fail, •The various technologies available for detecting potential failure sites, •The advantages and disadvantages of different diagnostic technologies, •Different approaches for utilities to employ cable system diagnostics. The primary deliverables of this project are this report, a Cable Diagnostic Handbook (a subset of this report) and an online

  10. Diagnostic value of stool DNA testing for multiple markers of colorectal cancer and advanced adenoma: a meta-analysis.

    Science.gov (United States)

    Yang, Hua; Xia, Bing-Qing; Jiang, Bo; Wang, Guozhen; Yang, Yi-Peng; Chen, Hao; Li, Bing-Sheng; Xu, An-Gao; Huang, Yun-Bo; Wang, Xin-Ying

    2013-08-01

    The diagnostic value of stool DNA (sDNA) testing for colorectal neoplasms remains controversial. To compensate for the lack of large-scale unbiased population studies, a meta-analysis was performed to evaluate the diagnostic value of sDNA testing for multiple markers of colorectal cancer (CRC) and advanced adenoma. The PubMed, Science Direct, Biosis Review, Cochrane Library and Embase databases were systematically searched in January 2012 without time restriction. Meta-analysis was performed using a random-effects model using sensitivity, specificity, diagnostic OR (DOR), summary ROC curves, area under the curve (AUC), and 95% CIs as effect measures. Heterogeneity was measured using the χ(2) test and Q statistic; subgroup analysis was also conducted. A total of 20 studies comprising 5876 individuals were eligible. There was no heterogeneity for CRC, but adenoma and advanced adenoma harboured considerable heterogeneity influenced by risk classification and various detection markers. Stratification analysis according to risk classification showed that multiple markers had a high DOR for the high-risk subgroups of both CRC (sensitivity 0.759 [95% CI 0.711 to 0.804]; specificity 0.883 [95% CI 0.846 to 0.913]; AUC 0.906) and advanced adenoma (sensitivity 0.683 [95% CI 0.584 to 0.771]; specificity 0.918 [95% CI 0.866 to 0.954]; AUC 0.946) but not for the average-risk subgroups of either. In the methylation subgroup, sDNA testing had significantly higher DOR for CRC (sensitivity 0.753 [95% CI 0.685 to 0.812]; specificity 0.913 [95% CI 0.860 to 0.950]; AUC 0.918) and advanced adenoma (sensitivity 0.623 [95% CI 0.527 to 0.712]; specificity 0.926 [95% CI 0.882 to 0.958]; AUC 0.910) compared with the mutation subgroup. There was no significant heterogeneity among studies for subgroup analysis. sDNA testing for multiple markers had strong diagnostic significance for CRC and advanced adenoma in high-risk subjects. Methylation makers had more diagnostic value than mutation

  11. Laser based beam diagnostic for the RAL Front End Test Stand (FETS)

    International Nuclear Information System (INIS)

    Gabor, C.; Lee, D. A.; Pozimski, J. K.; Letchford, A.

    2007-01-01

    For the diagnostic of high power particle beams, non-destructive measurement devices provide minimum influence on the beam and avoid various problems in connection with the high power density on surfaces. An H- ion beam offers the opportunity of non destructive beam diagnostics based on the effect of photo detachment. By the interaction of light with H- ions, the additional electron can be detached and a small number of neutrals will be produced. An additional magnetic dipole field can then be used to separate the detached electrons and neutrals from the ions. Using an integral detector the spatial distribution of the beam ion density can be derived, while the use of a spatial resolving detector enables to determine the phase space distribution. To investigate the measurement principle of the latter, a test stand was set up at the IAP in Frankfurt. This system will now be adopted to the requirements of the Front End Test Stand at CCLRC/ RAL. The aim of this FETS is to demonstrate a chopped H- beam of 60mA at 3MeV and 50pps with sufficiently high beam quality. The paper will present a detailed description of the proposed set up at RAL and discuss several results of simulations and experimental data gained in Frankfurt

  12. Self-diagnosis of malaria by travelers and expatriates: assessment of malaria rapid diagnostic tests available on the internet.

    Science.gov (United States)

    Maltha, Jessica; Gillet, Philippe; Heutmekers, Marloes; Bottieau, Emmanuel; Van Gompel, Alfons; Jacobs, Jan

    2013-01-01

    In the past malaria rapid diagnostic tests (RDTs) for self-diagnosis by travelers were considered suboptimal due to poor performance. Nowadays RDTs for self-diagnosis are marketed and available through the internet. The present study assessed RDT products marketed for self-diagnosis for diagnostic accuracy and quality of labeling, content and instructions for use (IFU). Diagnostic accuracy of eight RDT products was assessed with a panel of stored whole blood samples comprising the four Plasmodium species (n = 90) as well as Plasmodium negative samples (n = 10). IFUs were assessed for quality of description of procedure and interpretation and for lay-out and readability level. Errors in packaging and content were recorded. Two products gave false-positive test lines in 70% and 80% of Plasmodium negative samples, precluding their use. Of the remaining products, 4/6 had good to excellent sensitivity for the diagnosis of Plasmodium falciparum (98.2%-100.0%) and Plasmodium vivax (93.3%-100.0%). Sensitivity for Plasmodium ovale and Plasmodium malariae diagnosis was poor (6.7%-80.0%). All but one product yielded false-positive test lines after reading beyond the recommended reading time. Problems with labeling (not specifying target antigens (n = 3), and content (desiccant with no humidity indicator (n = 6)) were observed. IFUs had major shortcomings in description of test procedure and interpretation, poor readability and lay-out and user-unfriendly typography. Strategic issues (e.g. the need for repeat testing and reasons for false-negative tests) were not addressed in any of the IFUs. Diagnostic accuracy of RDTs for self-diagnosis was variable, with only 4/8 RDT products being reliable for the diagnosis of P. falciparum and P. vivax, and none for P. ovale and P. malariae. RDTs for self-diagnosis need improvements in IFUs (content and user-friendliness), labeling and content before they can be considered for self-diagnosis by the traveler.

  13. Developing a Cloze Procedure as a Reading Comprehension Achievement Test

    Directory of Open Access Journals (Sweden)

    I Ketut Seken

    2004-01-01

    Full Text Available The project was concerned with developing a cloze procedure as a reading comprehension achievement test. The subjects were students of the English Department of the Faculty of Letters, State University of Malang, who were halfway in the semester to complete Reading II course. The test was planned and constructed on the foundation of existing theory of cloze test construction. A review of theory concerning reading comprehension, testing reading comprehension, and cloze testing led to the construction of the test, including the decision concerning how to score the test and to interpret the scores. Using a class of 28 students, the test was tried out a week after the mid-semester test was administered by the Reading II teacher. It was found that the test is sufficienty reliable on the basis of a reliability coefficient of .79 through split-half procedure and a coefficient value of .78 by K-R 20. The test also showed high inter-section correlation. The validity of the test was viewed in terms of face, content, and construct. The test scores correlate moderately with those obtained from the mid-semester test by the teacher. Some problems are discussed and a suggestion made with regard to a possible solution to these problems.

  14. Allergic bronchopulmonary aspergillosis in Italian cystic fibrosis patients: Prevalence and percentage of positive tests in the employed diagnostic criteria

    International Nuclear Information System (INIS)

    Taccetti, Giovanni; Procopio, Elena; Marianelli, Lore; Campana, Silvia

    2000-01-01

    The prevalence of allergic bronchopulmonary aspergillosis (ABPA) in cystic fibrosis (CF) patients is difficult to determine because the data in the literature are not homogeneous or comparable. ABPA and CF have similar clinical symptoms which make diagnosis difficult and underestimate the real dimensions of the problem. We conducted an epidemiological study on 3089 Italian CF patients to determine the prevalence of ABPA in Italy and verify the percentage of positive tests in the employed diagnostic criteria. Our results indicate that the prevalence of ABPA in Italian CF patients is 6.18%, mainly in adolescents and young adults. ABPA is diagnosed using clinical symptoms (presence of episodic bronchial obstructions or typical radiographic features) and on the basis of other criteria which can only be partially fulfilled in paediatric patients. Among the diagnostic tests the most sensitive are the total IgE (84.5%), specific IgE anti-Aspergillus fumigatus (81.6%) and the prick test (68.3%). In the absence of clinical symptoms and gold standard diagnostic tests, serological positivity and/or the skin test are not sufficient evidence to confirm the presence of ABPA

  15. UREA BREATH TEST – ITS ROLE IN DIAGNOSTICS

    Directory of Open Access Journals (Sweden)

    Joško Osredkar

    2004-01-01

    reproduced.Conclusions. Invasive and noninvasive diagnostic tests for H. pylori are described. In a more detailed frame UBT is presented, the test which is recomended in certain instances by European Gastroenterologic Society. The UBT should be available for use in the doctor’s office to provide a rapid diagnosis.

  16. The FAO/IAEA External Quality Assurance Programme (EQAP) and movement towards a generic veterinary diagnostic testing laboratory accreditation scheme. Report of an FAO/IAEA consultants meeting

    International Nuclear Information System (INIS)

    2002-01-01

    establish a network of national veterinary diagnostic testing laboratories that are recognized for their achievements in establishing QA systems and their proficiency in the use of specific diagnostic assays. This network would facilitate the exchange of epidemiological information and, in the current atmosphere of international and regional trade agreements, provide a greater opportunity to increase the share of developing countries in the international trade of livestock and livestock products. In February 1998, a Consultants' Meeting was convened to consider the design, impact, and proposals for future implementation of the current FAO/IAEA EQAP for Animal Disease Diagnosis and make recommendations with regard to its central purposes and future direction. In addition, the Consultants considered the broader question of a generic QA 'accreditation' scheme for veterinary diagnostic testing laboratories that could be made available through international, regional, or national organizations as appropriate to the country of interest. This broader discussion was stimulated by the fact that few developed and no developing countries have nationally organized schemes to measure and recognize the QA systems and technical competence of veterinary diagnostic testing laboratories, but that such a scheme is of vital importance to the quality of policy decisions and actions taken on national animal health issues and the international trade of livestock and livestock commodities. It followed that, in the Subprogramme's role as a Collaborating Centre to the Office International Epizooties (OIE, or World Animal Health Organization), it would be appropriate to consider the FAO/IAEA EQAP within the broader scope of an international scheme for veterinary diagnostic laboratory accreditation for two reasons: 1) to use information learned through the design and implementation of the FAO/IAEA EQAP to assist in the appropriate development of an international scheme and 2) to ensure that the FAO

  17. Statistical Methods for the detection of answer copying on achievement tests

    NARCIS (Netherlands)

    Sotaridona, Leonardo

    2003-01-01

    This thesis contains a collection of studies where statistical methods for the detection of answer copying on achievement tests in multiple-choice format are proposed and investigated. Although all methods are suited to detect answer copying, each method is designed to address specific

  18. Diagnostic Imaging in Snakes and Lizards

    OpenAIRE

    Banzato , Tommaso

    2013-01-01

    The increasing popularity of snakes and lizards as pets has led to an increasing demand of specialised veterinary duties in these animals. Diagnostic imaging is often a fundamental step of the clinical investigation. The interpretation of diagnostic images is complex and requires a broad knowledge of anatomy, physiology and pathology of the species object of the clinical investigation. Moreover, in order to achieve a correct diagnosis, the comparison between normal and abnormal diagnostic im...

  19. Optimal number of tests to achieve and validate product reliability

    International Nuclear Information System (INIS)

    Ahmed, Hussam; Chateauneuf, Alaa

    2014-01-01

    The reliability validation of engineering products and systems is mandatory for choosing the best cost-effective design among a series of alternatives. Decisions at early design stages have a large effect on the overall life cycle performance and cost of products. In this paper, an optimization-based formulation is proposed by coupling the costs of product design and validation testing, in order to ensure the product reliability with the minimum number of tests. This formulation addresses the question about the number of tests to be specified through reliability demonstration necessary to validate the product under appropriate confidence level. The proposed formulation takes into account the product cost, the failure cost and the testing cost. The optimization problem can be considered as a decision making system according to the hierarchy of structural reliability measures. The numerical examples show the interest of coupling design and testing parameters. - Highlights: • Coupled formulation for design and testing costs, with lifetime degradation. • Cost-effective testing optimization to achieve reliability target. • Solution procedure for nested aleatoric and epistemic variable spaces

  20. Coping strategies as mediators in the relationship between test anxiety and academic achievement

    Directory of Open Access Journals (Sweden)

    Genc Ana

    2017-01-01

    Full Text Available In most modern societies, nearly every realm of life involves some form of evaluation of our knowledge, abilities and skills. Given the potentially significant consequences of exams, it is not surprising that they are often very stressful. This study aimed to determine the existence and nature of the relationships between level of test anxiety, coping strategies, and achieved success on a mid-term test. As well as examining the direct relations between the given variables, our primary interest was to investigate the potential mediating role of coping mechanisms between the input and output variables of the examined stressful transaction. The study was conducted on a sample of 263 students from the Psychology and German Studies Departments of the Faculty of Philosophy at the University of Novi Sad. According to our results, only emotion-focused coping mechanisms were statistically significant mediators in the relationship between level of test anxiety and mid-term test achievement. The results indicate that students with high test anxiety who employ predominantly emotion-focused coping strategies score lower on a pre-exam knowledge test.

  1. Diagnostic Role of Head-Bending and Lying-Down Tests in Lateral Canal Benign Paroxysmal Positional Vertigo.

    Science.gov (United States)

    Yetiser, Sertac; Ince, Dilay

    2015-08-01

    To compare the diagnostic value of the head-bending test (HBT), lying-down positioning test (LDPT) and patient's report to identify the affected canal in video-nystagmographically (VNG) confirmed patients with lateral canal benign paroxysmal positional vertigo (LC-BPPV). Case series with chart review. Head-bending, lying-down positioning and the head-roll maneuver (HRM) under VNG guidance. The data were collected in a referral community hospital. Seventy-eight patients (32 apogeotropic and 46 geotropic nystagmus) with LC-BPPV who had been recruited between 2009 and 2013 were enrolled in the study. Patients were tested with the HRM and then were asked about subjectively worse side. Later, they were subjected to HBT when sitting and the LDPT. The results were compared and studied with the 1-way ANOVA and chi-square tests. Statistical significance was set at p < 0.05. Affected side was identified by HRM in 75% of patients with apogeotropic nystagmus and 95.6% of patients with geotropic nystagmus. Approximately 65.6% of patients with apogeotropic and 52% of patients with geotropic nystagmus had nystagmus during LDPT. However, its comparability with HRM was low. However, treatment plan based on LDPT results alone provided relief of symptoms in additional 12.5% of patients with apogeotropic and in 2.2% of patients with geotropic nystagmus. Approximately 63% of patients with apogeotropic and 56% of patients with geotropic nystagmus were able to tell the worse side. Nystagmus comparable with HRM during HBT was low and not diagnostic. HRM has the greatest diagnostic value of positioning tests in LC-BPPV in this study. LDPT provides some contribution in the diagnosis of LC-BPPV but much less than HRM. Patients' subjective feeling of vertigo was also a useful test. However, HBT was not as sensitive as other measures in uncertain cases.

  2. Standardization of positive controls in diagnostic immunohistochemistry

    DEFF Research Database (Denmark)

    Torlakovic, Emina E; Nielsen, Søren; Francis, Glenn

    2015-01-01

    Diagnostic immunohistochemistry (dIHC) has been practiced for several decades, with an ongoing expansion of applications for diagnostic use, and more recently for detection of prognostic and predictive biomarkers. However, standardization of practice has yet to be achieved, despite significant...

  3. Evaluation of serological diagnostic tests for typhoid fever in Papua New Guinea using a composite reference standard.

    Science.gov (United States)

    Siba, Valentine; Horwood, Paul F; Vanuga, Kilagi; Wapling, Johanna; Sehuko, Rebecca; Siba, Peter M; Greenhill, Andrew R

    2012-11-01

    Typhoid fever remains a major global health problem. A major impediment to improving outcomes is the lack of appropriate diagnostic tools, which have not significantly improved in low-income settings for 100 years. We evaluated two commercially available rapid diagnostic tests (Tubex and TyphiDot), a prototype (TyphiRapid TR-02), and the commonly used single-serum Widal test in a previously reported high-burden area of Papua New Guinea. Samples were collected from 530 outpatients with axillary temperatures of ≥37.5°C, and analysis was conducted on all malaria-negative samples (n = 500). A composite reference standard of blood culture and PCR was used, by which 47 participants (9.4%) were considered typhoid fever positive. The sensitivity and specificity of the Tubex (51.1% and 88.3%, respectively) and TyphiDot (70.0% and 80.1%, respectively) tests were not high enough to warrant their ongoing use in this setting; however, the sensitivity and specificity for the TR-02 prototype were promising (89.4% and 85.0%, respectively). An axillary temperature of ≥38.5°C correlated with typhoid fever (P = 0.014). With an appropriate diagnostic test, conducting typhoid fever diagnosis only on patients with high-grade fever could dramatically decrease the costs associated with diagnosis while having no detrimental impact on the ability to accurately diagnose the illness.

  4. Cognitive diagnostic assessment via Bayesian evaluation of informative diagnostic hypotheses.

    NARCIS (Netherlands)

    Hoijtink, Herbert; Béland, Sébastien; Vermeulen, Jorine A.

    2014-01-01

    There exist diverse approaches that can be used for cognitive diagnostic assessment, such as mastery testing, constrained latent class analysis, rule space methodology, diagnostic cognitive modeling, and person-fit analysis. Each of these approaches can be used within 1 of the 4 psychometric

  5. Cognitive Diagnostic Assessment via Bayesian Evaluation of Informative Diagnostic Hypotheses

    NARCIS (Netherlands)

    Hoitink, Herbert; Beland, Sebastien; Vermeulen, Jorine

    2014-01-01

    There exist diverse approaches that can be used for cognitive diagnostic assessment, such as mastery testing, constrained latent class analysis, rule space methodology, diagnostic cognitive modeling, and person-fit analysis. Each of these approaches can be used within 1 of the 4 psychometric

  6. Diagnostic methods for insect sting allergy.

    Science.gov (United States)

    Hamilton, Robert G

    2004-08-01

    This review overviews advances from mid-2002 to the present in the validation and performance methods used in the diagnosis of Hymenoptera venom-induced immediate-type hypersensitivity. The general diagnostic algorithm for insect sting allergy is initially discussed with an examination of the AAAAI's 2003 revised practice parameter guidelines. Changes as a result of a greater recognition of skin test negative systemic reactors include repeat analysis of all testing and acceptance of serology as a complementary diagnostic test to the skin test. Original data examining concordance of venom-specific IgE results produced by the second-generation Pharmacia CAP System with the Johns Hopkins University radioallergosorbent test are presented. Diagnostic performance of honeybee venom-specific IgE assays used in clinical laboratories in North America is discussed using data from the Diagnostic Allergy Proficiency Survey conducted by the College of American Pathologists. Validity of venom-specific IgE antibody in postmortem blood specimens is demonstrated. The utility of alternative in-vivo (provocation) and in-vitro (basophil-based) diagnostic testing methods is critiqued. This overview supports the following conclusions. Improved practice parameter guidelines include serology and skin test as complementary in supporting a positive clinical history during the diagnostic process. Data are provided which support the analytical performance of commercially available venom-specific IgE antibody serology-based assays. Intentional sting challenge in-vivo provocation, in-vitro basophil flow cytometry (CD63, CD203c) based assays, and in-vitro basophil histamine and sulfidoleukotriene release assays have their utility in the study of difficult diagnostic cases, but their use will remain as supplementary, secondary diagnostic tests.

  7. Assessment of Pupils’ Personal Achievements

    Directory of Open Access Journals (Sweden)

    T. A. Strokova

    2012-01-01

    Full Text Available The implementation of the new state educational standards, based on the competence approach, requires some new criteria, procedures and diagnostic tools for estimating pupils’ personal achievements. However, there is a lack of necessary guidelines and recommendations for such objective evaluation and comparative analysis of the effectiveness of educational establishments. The urgent need for unified monitoring instruments induced the author to develop a criteria-diagnostic complex providing the options for evaluating the important personal development aspects – intellectual, value-oriented and moral. The author recommends a self-assessment method for evaluating the intellectual qualities (i.e. self-dependency, critical thinking, logics, flexibility, depth, originality, etc., intellectual competences, and moral traits. The method is based on the tests – «Pupil in his own eyes» and «Pupil in the expert teachers’ eyes». For examining the value orientation, the author takes the classical method by M. Rokich. The approbation of the complex evaluation method was carried out in Tyumen schools and lyceums regarding the last year pupils. The research findings and proposed assessment tools can be used by headmasters and school teachers for monitoring the pupils’ personal growth. 

  8. Vacuum system design and tritium inventory for the charge exchange diagnostic on the Tokamak Fusion Test Reactor

    International Nuclear Information System (INIS)

    Medley, S.S.

    1986-01-01

    The application of charge exchange analyzers for the measurement of ion temperature in fusion plasma experiments requires a direct connection between the diagnostic and plasma-discharge vacuum chambers. Differential pumping of the gas load from the diagnostic stripping cell operated at > or approx. = 10 -3 Torr is required to maintain the analyzer chamber at a pressure of -6 Torr. The migration of gases between the diagnostic and plasma vacuum chambers must be minimized. In particular, introduction of the analyzer stripping cell gas into the plasma chamber having a base pressure of -8 Torr must be suppressed. The charge exchange diagnostic for the Tokamak Fusion Test Reactor (TFTR) is comprised of two analyzer systems designed to contain a total of 18 independent mass/energy analyzers and one diagnostic neutral beam rated at 80 keV, 15 A. The associated arrays of multiple, interconnected vacuum systems were analyzed using the Vacuum System Transient Simulator (Vsts) computer program which models the transient transport of multigas species through complex networks of ducts, valves, traps, vacuum pumps, and other related vacuum system components. In addition to providing improved design performance at reduced costs, the analysis yields estimates for the exchange of tritium from the torus to the diagnostic components and of the diagnostic working gases to the torus

  9. The role of chronotype, gender, test anxiety, and conscientiousness in academic achievement of high school students.

    Science.gov (United States)

    Rahafar, Arash; Maghsudloo, Mahdis; Farhangnia, Sajedeh; Vollmer, Christian; Randler, Christoph

    2016-01-01

    Previous findings have demonstrated that chronotype (morningness/intermediate/eveningness) is correlated with cognitive functions, that is, people show higher mental performance when they do a test at their preferred time of day. Empirical studies found a relationship between morningness and higher learning achievement at school and university. However, only a few of them controlled for other moderating and mediating variables. In this study, we included chronotype, gender, conscientiousness and test anxiety in a structural equation model (SEM) with grade point average (GPA) as academic achievement outcome. Participants were 158 high school students and results revealed that boys and girls differed in GPA and test anxiety significantly, with girls reporting better grades and higher test anxiety. Moreover, there was a positive correlation between conscientiousness and GPA (r = 0.17) and morningness (r = 0.29), respectively, and a negative correlation between conscientiousness and test anxiety (r = -0.22). The SEM demonstrated that gender was the strongest predictor of academic achievement. Lower test anxiety predicted higher GPA in girls but not in boys. Additionally, chronotype as moderator revealed a significant association between gender and GPA for evening types and intermediate types, while intermediate types showed a significant relationship between test anxiety and GPA. Our results suggest that gender is an essential predictor of academic achievement even stronger than low or absent test anxiety. Future studies are needed to explore how gender and chronotype act together in a longitudinal panel design and how chronotype is mediated by conscientiousness in the prediction of academic achievement.

  10. Remote Visual Testing (RVT) for the diagnostic inspection of feedwater heaters

    International Nuclear Information System (INIS)

    Nugent, M.J.; Pellegrino, B.A.

    1993-01-01

    Feedwater heaters are an important component in the overall plant heat rate, reliability, availability, performance and maintenance considerations at power stations. The ability to diagnose heater problems in-situ properly can lead to: (1) Preventative plugging of damaged, but unfailed tubes; (2) In-place repair procedures; (3) Incorporation of corrective actions into replacement designs or heater/unit operations. The benefits and limitations of Non-Destructive Testing (NDT) on feedwater heaters are briefly reviewed. All Remote Visual Testing (RVT) including borescopes, fiberscopes, videoborescopes and Closed Circuit Television (CCTV) cameras are discussed along with currently accepted formats for documentation. The benefits of a comprehensive in-place inspection involving Remote Visual Testing are discussed in relationship to its diagnostic capabilities. The results of eight post-service heater inspections are discussed along with the root cause of failure of seven unique failure mechanisms. These inspections, including FWH access, RVT tool and data analysis, are detailed. 13 figs

  11. Modern diagnostic capabilities for vasospastic angina diagnostics (intracoronary provocative testing

    Directory of Open Access Journals (Sweden)

    А. А. Обединский

    2017-04-01

    Full Text Available This review is devoted to a topical problem of modern cardiology – techniques of diagnosing vasospastic angina. The results of retrospective and prospective studies on the efficacy and safety of vasospastic angina diagnostics are reviewed. The literature on the prevalence, progression and treatment of this pathology is discussed.Received 13 January 2017. Accepted 6 February 2017.Financing: The study did not have sponsorship.Conflict of interest: The authors declare no conflict of interest.

  12. Costs of novel tuberculosis diagnostics--will countries be able to afford it?

    Science.gov (United States)

    Pantoja, Andrea; Kik, Sandra V; Denkinger, Claudia M

    2015-04-01

    Four priority target product profiles for the development of diagnostic tests for tuberculosis were identified: 1) Rapid sputum-based (RSP), 2) non-sputum Biomarker-based (BMT), 3) triage test followed by confirmatory test (TT), and 4) drug-susceptibility testing (DST). We assessed the cost of the new tests in suitable strategies and of the conventional diagnosis of tuberculosis as per World Health Organization guidelines, in 36 high tuberculosis and MDR burden countries. Costs were then compared to the available funding for tuberculosis at country level. Costs of diagnosing tuberculosis using RSP ranged US$93-187 million/year; if RSP unit cost is of US$2-4 it would be lower/similar cost than conventional strategy with sputum smear microscopy (US$ 119 million/year). Using BMT (with unit cost of US$2-4) would cost US$70-121 million/year and be lower/comparable cost than conventional diagnostics. Using TT with TPP characteristics (unit cost of US$1-2) followed by Xpert would reduce diagnostic costs up to US$36 million/year. Costs of using different novel DST strategies for the diagnosis of drug resistance would be higher compared with conventional diagnosis. Introducing a TT or a biomarker test with optimal characteristics would be affordable from a cost and affordability perspective at the current available funding for tuberculosis. Additional domestic or donor funding would be needed in most countries to achieve affordability for other new diagnostic tests. © The Author 2014. Published by Oxford University Press on behalf of the Infectious Diseases Society of America. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.

  13. Diagnostic accuracy of point-of-care tests for hepatitis C virus infection: a systematic review and meta-analysis.

    Directory of Open Access Journals (Sweden)

    Mehnaaz Sultan Khuroo

    Full Text Available Point-of-care tests provide a plausible diagnostic strategy for hepatitis C infection in economically impoverished areas. However, their utility depends upon the overall performance of individual tests.A literature search was conducted using the metasearch engine Mettā, a query interface for retrieving articles from five leading medical databases. Studies were included if they employed point-of-care tests to detect antibodies of hepatitis C virus and compared the results with reference tests. Two reviewers performed a quality assessment of the studies and extracted data for estimating test accuracy.Thirty studies that had evaluated 30 tests fulfilled the inclusion criteria. The overall pooled sensitivity, specificity, positive likelihood-ratio, negative likelihood-ratio and diagnostic odds ratio for all tests were 97.4% (95% CI: 95.9-98.4, 99.5% (99.2-99.7, 80.17 (55.35-116.14, 0.03 (0.02-0.04, and 3032.85 (1595.86-5763.78, respectively. This suggested a high pooled accuracy for all studies. We found substantial heterogeneity between studies, but none of the subgroups investigated could account for the heterogeneity. Genotype diversity of HCV had no or minimal influence on test performance. Of the seven tests evaluated in the meta-regression model, OraQuick had the highest test sensitivity and specificity and showed better performance than a third generation enzyme immunoassay in seroconversion panels. The next highest test sensitivities and specificities were from TriDot and SDBioline, followed by Genedia and Chembio. The Spot and Multiplo tests produced poor test sensitivities but high test specificities. Nine of the remaining 23 tests produced poor test sensitivities and specificities and/or showed poor performances in seroconversion panels, while 14 tests had high test performances with diagnostic odds ratios ranging from 590.70 to 28822.20.Performances varied widely among individual point-of-care tests for diagnosis of hepatitis C virus

  14. A Personal Computer as Diagnostic Aid for Strabismus

    OpenAIRE

    Albicki, A.; Cohen, G.H.; Metz, H.S.

    1984-01-01

    This paper describes a microcomputer aided strabismus diagnostic system STRABCON. Two goals were achieved: at any time during the diagnostic process a list of plausible disorders are produced, and an optimal procedure for arriving at a final diagnosis is determined. This publication deals primarily with a microcomputer implementation of the STRABCON diagnostic system.

  15. Receiver operating characteristic (ROC) curves and the definition of threshold levels to diagnose coronary artery disease on electrocardiographic stress testing. Part II: the use of ROC curves in the choice of electrocardiographic stress test markers of ischaemia.

    Science.gov (United States)

    Marazìa, Stefania; Barnabei, Luca; De Caterina, Raffaele

    2008-01-01

    A common problem in diagnostic medicine, when performing a diagnostic test, is to obtain an accurate discrimination between 'normal' cases and cases with disease, owing to the overlapping distributions of these populations. In clinical practice, it is exceedingly rare that a chosen cut point will achieve perfect discrimination between normal cases and those with disease, and one has to select the best compromise between sensitivity and specificity by comparing the diagnostic performance of different tests or diagnostic criteria available. Receiver operating characteristic (or receiver operator characteristic, ROC) curves allow systematic and intuitively appealing descriptions of the diagnostic performance of a test and a comparison of the performance of different tests or diagnostic criteria. This review will analyse the basic principles underlying ROC curves and their specific application to the choice of optimal parameters on exercise electrocardiographic stress testing. Part II will be devoted to the comparative analysis of various parameters derived from exercise stress testing for the diagnosis of underlying coronary artery disease.

  16. Substitution of Pichia pastoris-derived recombinant proteins with mannose containing O- and N-linked glycans decreases specificity of diagnostic tests

    NARCIS (Netherlands)

    van Oort, Erica; Lerouge, Patrice; de Heer, Pleuni G.; Séveno, Martial; Coquet, Laurent; Modderman, Piet W.; Faye, Loïc; Aalberse, Rob C.; van Ree, Ronald

    2004-01-01

    Background: Recombinant proteins from Pichia pastoris need to be fully evaluated before used as diagnostic tools. Objective: The objective of this study was to investigate whether glycosylation by P. pastoris interferes with the specificity of diagnostic tests. Methods: An autoantigen involved in

  17. An evaluation of the diagnostic value of different skin tests with egg in clinically egg-allergic children having atopic dermatitis

    DEFF Research Database (Denmark)

    Hansen, Tine K; Høst, Arne; Bindslev-Jensen, Carsten

    2004-01-01

    Skin testing is a common diagnostic procedure in food allergy, but the final diagnosis of food allergy is based on the clinical response to food challenge. We studied the value of the skin prick-prick test (SPT), skin application food test (SAFT) and atopy patch test (APT) with fresh egg extract......-allergic children were positive in SPT and 40-60% in APT. In APT and in SPT false-positive reactions to egg were observed. In this study comprising a small number of patients including control subjects, neither SAFT nor APT with fresh whole egg extract were able to increase the diagnostic accuracy in detecting egg...

  18. Bench-top validation testing of selected immunological and molecular Renibacterium salmoninarum diagnostic assays by comparison with quantitative bacteriological culture

    Science.gov (United States)

    Elliott, D.G.; Applegate, L.J.; Murray, A.L.; Purcell, M.K.; McKibben, C.L.

    2013-01-01

    No gold standard assay exhibiting error-free classification of results has been identified for detection of Renibacterium salmoninarum, the causative agent of salmonid bacterial kidney disease. Validation of diagnostic assays for R. salmoninarum has been hindered by its unique characteristics and biology, and difficulties in locating suitable populations of reference test animals. Infection status of fish in test populations is often unknown, and it is commonly assumed that the assay yielding the most positive results has the highest diagnostic accuracy, without consideration of misclassification of results. In this research, quantification of R. salmoninarum in samples by bacteriological culture provided a standardized measure of viable bacteria to evaluate analytical performance characteristics (sensitivity, specificity and repeatability) of non-culture assays in three matrices (phosphate-buffered saline, ovarian fluid and kidney tissue). Non-culture assays included polyclonal enzyme-linked immunosorbent assay (ELISA), direct smear fluorescent antibody technique (FAT), membrane-filtration FAT, nested polymerase chain reaction (nested PCR) and three real-time quantitative PCR assays. Injection challenge of specific pathogen-free Chinook salmon, Oncorhynchus tshawytscha (Walbaum), with R. salmoninarum was used to estimate diagnostic sensitivity and specificity. Results did not identify a single assay demonstrating the highest analytical and diagnostic performance characteristics, but revealed strengths and weaknesses of each test.

  19. Diagnostic performance of a rapid in-clinic test for the detection of Canine Parvovirus under different storage conditions and vaccination status.

    Science.gov (United States)

    Kantere, Maria C; Athanasiou, Labrini V; Spyrou, Vassiliki; Kyriakis, Constantinos S; Kontos, Vassilios; Chatzopoulos, Dimitrios C; Tsokana, Constantina N; Billinis, Charalambos

    2015-04-01

    Canine parvovirus (CPV) is one of the most common causes of acute haemorrhagic enteritis in young dogs, while clinical diagnosis is often indecisive. The aim of our study was to evaluate the diagnostic accuracy of an in-clinic rapid test in the detection of CPV infection in dogs. To this end, we compared the Rapid Diagnostic Kit of Canine Parvovirus, Coronavirus and Rotavirus antigen (Quicking(®)) to PCR, which is considered as the most reliable diagnostic method. A total of 78 duplicated faecal samples were collected from diarrhoeic dogs. Vaccination history within a month prior to the onset of diarrhoea was reported for 12 of the sampled dogs. The rapid diagnostic test was performed in 23 of the faecal samples directly, while the rest were placed into a sterile cotton tipped swab suitable for collection and transportation of viruses (Sigma Σ-VCM(®)) and stored at -20 °C. The sensitivity of the Quicking rapid diagnostic test compared to PCR in the total number of samples, in samples from non-vaccinated dogs and in samples tested directly after collection were 22.22% (95% CI: 13.27-33.57%), 26.67% (95% CI: 16.08-39.66%) and 76.47% (95% CI: 50.10-93.04%) respectively, while the specificity of the test was 100% in any case. In conclusion, negative results do not exclude parvoenteritis from the differential diagnosis, especially in dogs with early vaccination history, but a positive result almost certainly indicates CPV infection. An improved sensitivity may be expected when the test is performed immediately. Copyright © 2015 Elsevier B.V. All rights reserved.

  20. Turning the Page: Advancing Paper-Based Microfluidics for Broad Diagnostic Application.

    Science.gov (United States)

    Gong, Max M; Sinton, David

    2017-06-28

    Infectious diseases are a major global health issue. Diagnosis is a critical first step in effectively managing their spread. Paper-based microfluidic diagnostics first emerged in 2007 as a low-cost alternative to conventional laboratory testing, with the goal of improving accessibility to medical diagnostics in developing countries. In this review, we examine the advances in paper-based microfluidic diagnostics for medical diagnosis in the context of global health from 2007 to 2016. The theory of fluid transport in paper is first presented. The next section examines the strategies that have been employed to control fluid and analyte transport in paper-based assays. Tasks such as mixing, timing, and sequential fluid delivery have been achieved in paper and have enabled analytical capabilities comparable to those of conventional laboratory methods. The following section examines paper-based sample processing and analysis. The most impactful advancement here has been the translation of nucleic acid analysis to a paper-based format. Smartphone-based analysis is another exciting development with potential for wide dissemination. The last core section of the review highlights emerging health applications, such as male fertility testing and wearable diagnostics. We conclude the review with the future outlook, remaining challenges, and emerging opportunities.

  1. Performance-based alternative assessments as a means of eliminating gender achievement differences on science tests

    Science.gov (United States)

    Brown, Norman Merrill

    1998-09-01

    Historically, researchers have reported an achievement difference between females and males on standardized science tests. These differences have been reported to be based upon science knowledge, abstract reasoning skills, mathematical abilities, and cultural and social phenomena. This research was designed to determine how mastery of specific science content from public school curricula might be evaluated with performance-based assessment models, without producing gender achievement differences. The assessment instruments used were Harcourt Brace Educational Measurement's GOALSsp°ler: A Performance-Based Measure of Achievement and the performance-based portion of the Stanford Achievement Testspcopyright, Ninth Edition. The identified independent variables were test, gender, ethnicity, and grade level. A 2 x 2 x 6 x 12 (test x gender x ethnicity x grade) factorial experimental design was used to organize the data. A stratified random sample (N = 2400) was selected from a national pool of norming data: N = 1200 from the GOALSsp°ler group and N = 1200 from the SAT9spcopyright group. The ANOVA analysis yielded mixed results. The factors of test, gender, ethnicity by grade, gender by grade, and gender by grade by ethnicity failed to produce significant results (alpha = 0.05). The factors yielding significant results were ethnicity, grade, and ethnicity by grade. Therefore, no significant differences were found between female and male achievement on these performance-based assessments.

  2. Diagnostic challenges of childhood asthma.

    Science.gov (United States)

    Bakirtas, Arzu

    2017-01-01

    Diagnosis of asthma in childhood is challenging. Both underdiagnosis and overdiagnosis of asthma are important issues. The present review gives information about challenging factors for an accurate diagnosis of childhood asthma. Although underdiagnosis of asthma in childhood has always been the most important diagnostic problem, overdiagnosis of asthma has also been increasingly recognized. This is probably due to diagnosis of asthma based on symptoms and signs alone. Demonstration of variable airflow obstruction by lung function tests is the most common asthma diagnostic tests used in practice and is therefore strongly recommended in children who can cooperate. Recently, an asthma guideline combining the clinical and economic evidences with sensitivity and specificity of diagnostic procedures was developed to improve accuracy of diagnosis and to avoid overdiagnosis. This guideline provided an algorithmic clinical and cost-effective approach and included fractional exhaled nitric oxide measurement as one of the diagnostic tests in addition to lung function. Diagnosis of asthma in children should be made by combining relevant history with at least two confirmatory diagnostic tests whenever possible. Diagnosis based on short-period treatment trials should be limited to young children who are unable to cooperate with these tests.

  3. DETECTION OF RABIES VIRAL ANTIGEN IN CATTLE BY RAPID IMMUNOCHROMTOGRAPHIC DIAGNOSTIC TEST

    Directory of Open Access Journals (Sweden)

    Santanu Panda

    2016-06-01

    Full Text Available In recent years, improved quality, accuracy and speed for diagnosis of rabies has been adopted for rabies control strategies in developing countries. In field condition, rapid immunochromtographic diagnostic test (RIDT is a true requirement for rapid epidemiological surveillance of rabies. In the present study, a total of ten numbers of rabies suspected cattle brain sample form different parts of West Bengal, India were examined through RIDT. The results revealed that one sample was found to be positive. The test was established as powerful screening tool for rabies with high sensitivity and specificity. Thus, RIDT can be employed as a reliable and quick approach for diagnosis and control of rabies under field condition.

  4. A microcosting study of diagnostic tests for the detection of coronary artery disease in the Netherlands

    International Nuclear Information System (INIS)

    Tan, S.S.; Oppe, M.; Zoet-Nugteren, S.K.; Niezen, R.A.; Kofflard, M.J.M.; Ten Cate, F.J.; Roijen, L. Hakkaart-van

    2009-01-01

    Objective: The primary aim of the present study was to calculate the actual costs of four diagnostic tests for the detection of coronary artery disease in the Netherlands using a microcosting methodology. As a secondary objective, the cost effectiveness of eight diagnostic strategies was examined, using microcosting and reimbursement fees subsequently as the cost estimate. Design: A multicenter, retrospective cost analysis from a hospital perspective. Setting: The study was conducted in three general hospitals in the Netherlands for 2006. Interventions: Exercise electrocardiography (exECG), stress echocardiography (sECHO), single-photon emission computed tomography (SPECT) and coronary angiography (CA). Results: The actual costs of exECG, sECHO, SPECT and CA were Euro 33, 216, 614 and 1300 respectively. For all diagnostic tests, labour and indirect cost components (overheads and capital) together accounted for over 75% of the total costs. Consumables played a relatively important role in SPECT (14%). Hotel and nutrition were only applicable to SPECT and CA. Diagnostic services were solely performed for CA, but their costs were negligible (2%). Using microcosting estimates, exECG-sECHO-SPECT-CA was the most and CA the least cost effective strategy ( Euro 397 and 1302 per accurately diagnosed patient). Using reimbursement fees, exECG-sECHO-CA was most and SPECT-CA least cost effective ( Euro 147 and 567 per accurately diagnosed patient). Conclusions: The use of microcosting estimates instead of reimbursement fees led to different conclusions regarding the relative cost effectiveness of alternative strategies.

  5. Individual Differences in Digit Span, Susceptibility to Proactive Interference, and Aptitude/Achievement Test Scores.

    Science.gov (United States)

    Dempster, Frank N.; Cooney, John B.

    1982-01-01

    Individual differences in digit span, susceptibility to proactive interference, and various aptitude/achievement test scores were investigated in two experiments with college students. Results indicated that digit span was strongly correlated with aptitude/achievement scores, but did not indicate that susceptibility to proactive interference…

  6. Comorbidity negatively influences the outcomes of diagnostic tests for musculoskeletal pain in the orofacial region

    NARCIS (Netherlands)

    Koutris, M.; Visscher, C.M.; Lobbezoo, F.; Naeije, M.

    2013-01-01

    The aim of this study was to investigate whether diagnostic tests for musculoskeletal pain in the orofacial region [temporomandibular disorder (TMD) pain] are influenced by the presence of comorbid conditions, and to determine whether this influence decreases when the presence of "familiar pain" is

  7. Construction and characterization of a plasma focus device and diagnostic test ion

    International Nuclear Information System (INIS)

    Morales Arango, Diana Marsela

    2013-01-01

    In this work we designed and built a Plasma Focus device 2kJ power in order to extend the energy range of devices designed in DPTN CCHEN and study the scaling laws type Plasma Focus Device. The operating parameters of this device are: T/ 4 =907ns, C = 8000nF, L = 42nH, E = 2kJ, lo = 276kA. In such a way to optimize the device tests were performed with various electrode configurations, insulator length, to determine the conditions under which it operates in Plasma Focus mode. Subsequent to the construction tests were performed on devices PF-400J (T /4 = 300ns, C = 880nF, L = 38nH, E = 400J, lo = 168kA) y PF-2kJ (device between the hundreds of joules and kilojoules of energy) diagnostic charged particle emission used the Faraday Cup consisting of a biased graphite collector. For a series of shots on the PF-400J and PF-2kJ operated at 27kV and 20kV respectively kinetic energy distribution of proton between 60keV-150keV were found, deuterons between 60KeV-300KeV. With the idea of optimizing the results in future diagnostic type spectrometer Thompson, spectroscopy and diffraction networks in gas mixture will be implemented

  8. Final design of ITER port plug test facility

    Energy Technology Data Exchange (ETDEWEB)

    Cerisier, Thierry, E-mail: thierry.cerisier@yahoo.fr [ITER Organization, Route de Vinon-sur-Verdon, CS 90046, St Paul-lez-Durance Cedex, 13067 (France); Levesy, Bruno [ITER Organization, Route de Vinon-sur-Verdon, CS 90046, St Paul-lez-Durance Cedex, 13067 (France); Romannikov, Alexander [Institution “Project Center ITER”, Kurchatov sq. 1, Building 3, Moscow 123182 (Russian Federation); Rumyantsev, Yuri [JSC “Cryogenmash”, Moscow reg., Balashikha 143907 (Russian Federation); Cordier, Jean-Jacques; Dammann, Alexis [ITER Organization, Route de Vinon-sur-Verdon, CS 90046, St Paul-lez-Durance Cedex, 13067 (France); Minakov, Victor; Rosales, Natalya; Mitrofanova, Elena [JSC “Cryogenmash”, Moscow reg., Balashikha 143907 (Russian Federation); Portone, Sergey; Mironova, Ekaterina [Institution “Project Center ITER”, Kurchatov sq. 1, Building 3, Moscow 123182 (Russian Federation)

    2016-11-01

    Highlights: • We introduce the port plug test facility (purpose and status of the design). • We present the PPTF sub-systems. • We present the environmental and functional tests. • We present the occupational and nuclear safety functions. • We conclude on the achievements and next steps. - Abstract: To achieve the overall ITER machine availability target, the availability of diagnostics and heating port plugs shall be as high as 99.5%. To fulfill this requirement, it is mandatory to test the port plugs at operating temperature before installation on the machine and after refurbishment. The ITER port plug test facility (PPTF) is composed of several test stands that can be used to test the port plugs whereas at the end of manufacturing (in a non-nuclear environment), or after refurbishment in the ITER hot cell facility. The PPTF provides the possibility to perform environmental (leak tightness, vacuum and thermo-hydraulic performances) and functional tests (radio frequency acceptance tests, behavior of the plugs’ steering mechanism and calibration of diagnostics) on upper and equatorial port plugs. The final design of the port plug test facility is described. The configuration of the standalone test stands and the integration in the hot cell facility are presented.

  9. Using molecular diagnostic testing to personalize the treatment of patients with gastrointestinal stromal tumors.

    Science.gov (United States)

    Bannon, Amber E; Klug, Lillian R; Corless, Christopher L; Heinrich, Michael C

    2017-05-01

    The diagnosis and treatment of gastrointestinal stromal tumor (GIST) has emerged as a paradigm for modern cancer treatment ('precision medicine'), as it highlights the importance of matching molecular defects with specific therapies. Over the past two decades, the molecular classification and diagnostic work up of GIST has been radically transformed, accompanied by the development of molecular therapies for specific subgroups of GIST. This review summarizes the developments in the field of molecular diagnosis of GIST, particularly as they relate to optimizing medical therapy. Areas covered: Based on an extensive literature search of the molecular and clinical aspects of GIST, the authors review the most important developments in this field with an emphasis on the differential diagnosis of GIST including mutation testing, therapeutic implications of each molecular subtype, and emerging technologies relevant to the field. Expert commentary: The use of molecular diagnostics to classify GIST has been shown to be successful in optimizing patient treatment, but these methods remain under-utilized. In order to facilitate efficient and comprehensive molecular testing, the authors have developed a decision tree to aid clinicians.

  10. Development and Application of Diagnostic Test to Identify Students' Misconceptions of Quantum Physics

    International Nuclear Information System (INIS)

    Halim, A.A.; Meerah, T.S.; Lilia Halim

    2009-01-01

    A study on students' misconceptions on quantum physics is rarely being done, because the target audience is quite small. It is important to understand quantum physics concepts correctly especially for science students. This study was under taken to help students identify their misconceptions at the early stage. The aim of this study is to develop a diagnostic test which can access the students' misconceptions, and use the findings for the benefits of quantum physics courses. A multiple-choice Quantum Physics Diagnostic Test (QPDT), that involves concepts of light, atomic model, particle-wave dualism, wave function, and potential energy, was administered to 200 university students. The results shows that many students use the classical concepts to describe the quantum phenomenon. For example students describe light only as a wave, an electron only as a particle, and that the atomic structure is parallel to the solar system. To overcome these problems, it is suggested that lecturers spend more time in explaining the basic definitions and using analogies in quantum physics teaching. (author)

  11. Design standards for experimental and field studies to evaluate diagnostic accuracy of tests for infectious diseases in aquatic animals.

    Science.gov (United States)

    Laurin, E; Thakur, K K; Gardner, I A; Hick, P; Moody, N J G; Crane, M S J; Ernst, I

    2018-05-01

    Design and reporting quality of diagnostic accuracy studies (DAS) are important metrics for assessing utility of tests used in animal and human health. Following standards for designing DAS will assist in appropriate test selection for specific testing purposes and minimize the risk of reporting biased sensitivity and specificity estimates. To examine the benefits of recommending standards, design information from published DAS literature was assessed for 10 finfish, seven mollusc, nine crustacean and two amphibian diseases listed in the 2017 OIE Manual of Diagnostic Tests for Aquatic Animals. Of the 56 DAS identified, 41 were based on field testing, eight on experimental challenge studies and seven on both. Also, we adapted human and terrestrial-animal standards and guidelines for DAS structure for use in aquatic animal diagnostic research. Through this process, we identified and addressed important metrics for consideration at the design phase: study purpose, targeted disease state, selection of appropriate samples and specimens, laboratory analytical methods, statistical methods and data interpretation. These recommended design standards for DAS are presented as a checklist including risk-of-failure points and actions to mitigate bias at each critical step. Adherence to standards when designing DAS will also facilitate future systematic review and meta-analyses of DAS research literature. © 2018 John Wiley & Sons Ltd.

  12. A correlation electron cyclotron emission diagnostic and the importance of multifield fluctuation measurements for testing nonlinear gyrokinetic turbulence simulations.

    Science.gov (United States)

    White, A E; Schmitz, L; Peebles, W A; Carter, T A; Rhodes, T L; Doyle, E J; Gourdain, P A; Hillesheim, J C; Wang, G; Holland, C; Tynan, G R; Austin, M E; McKee, G R; Shafer, M W; Burrell, K H; Candy, J; DeBoo, J C; Prater, R; Staebler, G M; Waltz, R E; Makowski, M A

    2008-10-01

    A correlation electron cyclotron emission (CECE) diagnostic has been used to measure local, turbulent fluctuations of the electron temperature in the core of DIII-D plasmas. This paper describes the hardware and testing of the CECE diagnostic and highlights the importance of measurements of multifield fluctuation profiles for the testing and validation of nonlinear gyrokinetic codes. The process of testing and validating such codes is critical for extrapolation to next-step fusion devices. For the first time, the radial profiles of electron temperature and density fluctuations are compared to nonlinear gyrokinetic simulations. The CECE diagnostic at DIII-D uses correlation radiometry to measure the rms amplitude and spectrum of the electron temperature fluctuations. Gaussian optics are used to produce a poloidal spot size with w(o) approximately 1.75 cm in the plasma. The intermediate frequency filters and the natural linewidth of the EC emission determine the radial resolution of the CECE diagnostic, which can be less than 1 cm. Wavenumbers resolved by the CECE diagnostic are k(theta) < or = 1.8 cm(-1) and k(r) < or = 4 cm(-1), relevant for studies of long-wavelength turbulence associated with the trapped electron mode and the ion temperature gradient mode. In neutral beam heated L-mode plasmas, core electron temperature fluctuations in the region 0.5 < r/a < 0.9, increase with radius from approximately 0.5% to approximately 2%, similar to density fluctuations that are measured simultaneously with beam emission spectroscopy. After incorporating "synthetic diagnostics" to effectively filter the code output, the simulations reproduce the characteristics of the turbulence and transport at one radial location r/a = 0.5, but not at a second location, r/a = 0.75. These results illustrate that measurements of the profiles of multiple fluctuating fields can provide a significant constraint on the turbulence models employed by the code.

  13. Evaluation of the Effect of Diagnostic Molecular Testing on the Surgical Decision-Making Process for Patients With Thyroid Nodules.

    Science.gov (United States)

    Noureldine, Salem I; Najafian, Alireza; Aragon Han, Patricia; Olson, Matthew T; Genther, Dane J; Schneider, Eric B; Prescott, Jason D; Agrawal, Nishant; Mathur, Aarti; Zeiger, Martha A; Tufano, Ralph P

    2016-07-01

    Diagnostic molecular testing is used in the workup of thyroid nodules. While these tests appear to be promising in more definitively assigning a risk of malignancy, their effect on surgical decision making has yet to be demonstrated. To investigate the effect of diagnostic molecular profiling of thyroid nodules on the surgical decision-making process. A surgical management algorithm was developed and published after peer review that incorporated individual Bethesda System for Reporting Thyroid Cytopathology classifications with clinical, laboratory, and radiological results. This algorithm was created to formalize the decision-making process selected herein in managing patients with thyroid nodules. Between April 1, 2014, and March 31, 2015, a prospective study of patients who had undergone diagnostic molecular testing of a thyroid nodule before being seen for surgical consultation was performed. The recommended management undertaken by the surgeon was then prospectively compared with the corresponding one in the algorithm. Patients with thyroid nodules who did not undergo molecular testing and were seen for surgical consultation during the same period served as a control group. All pertinent treatment options were presented to each patient, and any deviation from the algorithm was recorded prospectively. To evaluate the appropriateness of any change (deviation) in management, the surgical histopathology diagnosis was correlated with the surgery performed. The study cohort comprised 140 patients who underwent molecular testing. Their mean (SD) age was 50.3 (14.6) years, and 75.0% (105 of 140) were female. Over a 1-year period, 20.3% (140 of 688) had undergone diagnostic molecular testing before surgical consultation, and 79.7% (548 of 688) had not undergone molecular testing. The surgical management deviated from the treatment algorithm in 12.9% (18 of 140) with molecular testing and in 10.2% (56 of 548) without molecular testing (P = .37). In the group with

  14. A Molecular Diagnostic Test for Persistent Müllerian Duct Syndrome in Miniature Schnauzer Dogs

    OpenAIRE

    Pujar, S.; Meyers-Wallen, V.N.

    2009-01-01

    In persistent Müllerian duct syndrome (PMDS), Müllerian ducts fail to regress in males during sexual differentiation. In the canine miniature schnauzer model, PMDS is caused by a C to T transition in exon 3 of the Müllerian inhibiting substance type II receptor (MISRII), which introduces a DdeI restriction site. Here we report a molecular diagnostic test for PMDS in the miniature schnauzer to identify affected dogs and carriers. As our test results suggest that the mutation is identical by de...

  15. Radiation protection type testing and licensing of diagnostic X-ray equipment in the GDR

    International Nuclear Information System (INIS)

    Taschner, P.; Poulheim, K.F.; Feldheim, W.

    1987-01-01

    The results of more than 10 years experience in type testing and type licensing of diagnostic X-ray equipment with respect to meeting radiation protection requirements as well as the implications for the conduct of these procedures resulting from the introduction of new radiation protection legislation in 1983 and 1984, are described. At present an updated version of the 'Regulation of 16 December 1977 concerning radiation protection type testing and licensing of sealed radiation sources and equipment emitting ionizing radiation' is being prepared. (author)

  16. Uncertainty during breast diagnostic evaluation: state of the science.

    Science.gov (United States)

    Montgomery, Mariann

    2010-01-01

    To present the state of the science on uncertainty in relationship to the experiences of women undergoing diagnostic evaluation for suspected breast cancer. Published articles from Medline, CINAHL, PubMED, and PsycINFO from 1983-2008 using the following key words: breast biopsy, mammography, uncertainty, reframing, inner strength, and disruption. Fifty research studies were examined with all reporting the presence of anxiety persisting throughout the diagnostic evaluation until certitude is achieved through the establishment of a definitive diagnosis. Indirect determinants of uncertainty for women undergoing breast diagnostic evaluation include measures of anxiety, depression, social support, emotional responses, defense mechanisms, and the psychological impact of events. Understanding and influencing the uncertainty experience have been suggested to be key in relieving psychosocial distress and positively influencing future screening behaviors. Several studies examine correlational relationships among anxiety, selection of coping methods, and demographic factors that influence uncertainty. A gap exists in the literature with regard to the relationship of inner strength and uncertainty. Nurses can be invaluable in assisting women in coping with the uncertainty experience by providing positive communication and support. Nursing interventions should be designed and tested for their effects on uncertainty experienced by women undergoing a breast diagnostic evaluation.

  17. Identification misconception of primary school teacher education students in changes of matters using a five-tier diagnostic test

    Science.gov (United States)

    Bayuni, T. C.; Sopandi, W.; Sujana, A.

    2018-05-01

    This research was conducted on third grade students (III) semester six, with sample number 84 respondents. The method used in this research is descriptive method. This article identifies the misconceptions of Primary School Teacher Education students by using a five tier diagnostic test research instrument, a question adapted to three chemical representations accompanied by an open reason and a level of confidence in the choice of answers. The categorization of the five tier diagnostic test scoring is divided into four namely, understand the concept, lack of concept, misconception and not understand the concept. Questionnaire in the form of a closed questionnaire is used to determine the factors that cause misconception. The data obtained is misconception has the highest percentage on the concept of substance properties and changes in its form. The highest incidence of misconceptions is due to self-factors. The conclusion is that five tier diagnostic tests can be used to uncover misconceptions of elementary school teachers and assist teachers in presenting lesson material tailored to the chemical representation so that students can understand the concept of the nature of matter and change its form well.

  18. Investigation of publication bias in meta-analyses of diagnostic test accuracy: a meta-epidemiological study

    NARCIS (Netherlands)

    van Enst, W. Annefloor; Ochodo, Eleanor; Scholten, Rob J. P. M.; Hooft, Lotty; Leeflang, Mariska M.

    2014-01-01

    The validity of a meta-analysis can be understood better in light of the possible impact of publication bias. The majority of the methods to investigate publication bias in terms of small study-effects are developed for meta-analyses of intervention studies, leaving authors of diagnostic test

  19. Parent Rated Symptoms of Inattention in Childhood Predict High School Academic Achievement Across Two Culturally and Diagnostically Diverse Samples

    Directory of Open Access Journals (Sweden)

    Astri J. Lundervold

    2017-08-01

    Full Text Available Objective: To investigate parent reports of childhood symptoms of inattention as a predictor of adolescent academic achievement, taking into account the impact of the child’s intellectual functioning, in two diagnostically and culturally diverse samples.Method: Samples: (a an all-female sample in the U.S. predominated by youth with ADHD (Berkeley Girls with ADHD Longitudinal Study [BGALS], N = 202, and (b a mixed-sex sample recruited from a Norwegian population-based sample (the Bergen Child Study [BCS], N = 93. Inattention and intellectual function were assessed via the same measures in the two samples; academic achievement scores during and beyond high school and demographic covariates were country-specific.Results: Childhood inattention predicted subsequent academic achievement in both samples, with a somewhat stronger effect in the BGALS sample, which included a large subgroup of children with ADHD. Intellectual function was another strong predictor, but the effect of early inattention remained statistically significant in both samples when intellectual function was covaried.Conclusion: The effect of early indicators of inattention on future academic success was robust across the two samples. These results support the use of remediation procedures broadly applied. Future longitudinal multicenter studies with pre-planned common inclusion criteria should be performed to increase our understanding of the importance of inattention in primary school children for concurrent and prospective functioning.

  20. Cost-effectiveness analysis of introducing malaria diagnostic testing in drug shops

    DEFF Research Database (Denmark)

    Hansen, Kristian Schultz; Clarke, Siân E.; Lal, Sham

    2017-01-01

    Background Private sector drug shops are an important source of malaria treatment in Africa, yet diagnosis without parasitological testing is common among these providers. Accurate rapid diagnostic tests for malaria (mRDTs) require limited training and present an opportunity to increase access...... to correct diagnosis. The present study was a cost-effectiveness analysis of the introduction of mRDTs in Ugandan drug shops. Methods Drug shop vendors were trained to perform and sell subsidised mRDTs and artemisinin-based combination therapies (ACTs) in the intervention arm while vendors offered ACTs...... following presumptive diagnosis of malaria in the control arm. The effect on the proportion of customers with fever ‘appropriately treated of malaria with ACT’ was captured during a randomised trial in drug shops in Mukono District, Uganda. Health sector costs included: training of drug shop vendors...

  1. Sex differences in mathematical achievement: Grades, national test, and self-confidence

    Directory of Open Access Journals (Sweden)

    Egorova, Marina S.

    2016-09-01

    Full Text Available Academic achievement, which is inherently an indicator of progress in the curriculum, can also be viewed as an indirect measure of cognitive development, social adaptation, and motivational climate characteristics. In addition to its direct application, academic achievement is used as a mediating factor in the study of various phenomena, from the etiology of learning disabilities to social inequality. Analysis of sex differences in mathematical achievement is considered particularly important for exploring academic achievement, since creating an adequate educational environment with equal opportunities for boys and girls serves as a prerequisite for improving the overall mathematical and technical literacy that is crucial for modern society, creates balanced professional opportunities, and destroys traditional stereotypes about the roles of men and women in society. The objective of our research was to analyze sex differences in mathematical achievement among high school students and to compare various methods for diagnosing academic performance, such as school grades, test scores, and self-concept. The results were obtained through two population studies whose samples are representative of the Russian population in the relevant age group. Study 1 looked at sex differences in math grades among twins (n = 1,234 pairs and singletons (n = 2,227 attending high school. The sample of Study 2 comprised all twins who took the Unified State Examination in 2010–2012. The research analyzed sex differences in USE math scores across the entire sample and within the extreme subgroups. It also explored differences between boys and girls in opposite-sex dizygotic (DZ twin pairs. The key results were as follows. No difference in mathematical achievement was observed between twins and singletons. Sex differences were found in all measures of mathematical achievement. Girls had higher school grades in math than boys, while boys outperformed girls in USE math

  2. [Diagnostic advantages of the test system "DS-EIA-HBsAg-0.01" for detection of HBV surface antigen].

    Science.gov (United States)

    Egorova, N I; Pyrenkova, I Iu; Igolkina, S N; Sharipova, I N; Puzyrev, V F; Obriadina, A P; Burkov, A N; Kornienko, N V; Fields, H A; Korovkin, A S; Shalunova, N V; Bektemirov, T A; Kuznetsov, K V; Koshcheeva, N A; Ulanova, T I

    2009-01-01

    The new highly sensitive test system "DS-EIA-HBsAg-0.01" (Priority Certificate No. 2006129019 of August 10, 2006) in detecting hepatitis B surface antigen (HBsAg) was assessed. The sensitivity of the test was estimated using the federal standards sample HBsAg 42-28-311-06, panels' samples Boston Biomedica Inc. (West Bridgewater, Mass, USA) and ZeptoMetrix Corp. (Buffalo, NY, USA). The findings have indicated that "DS-EIA-HBsAg-0.01" is equally effective in detecting different subtypes of HBsAg during a seroconversion period earlier than alternative assays. Along with its high analytical and diagnostic sensitivity, the system shows a high diagnostic specificity.

  3. Screening for Wilson disease in acute liver failure: a comparison of currently available diagnostic tests

    DEFF Research Database (Denmark)

    Korman, J.D.; Volenberg, I.; Balko, J.

    2008-01-01

    a diagnostic sensitivity of 21% and specificity of 84% while, by nephelometry, a sensitivity of 56% and specificity of 63%. Serum copper levels exceeded 200 microg/dL in all ALF-WD patients measured (13/16), but were also elevated in non-WD ALF. An alkaline phosphatase (AP) to total bilirubin (TB) ratio ... and specificity of 100%. CONCLUSION: Conventional WD testing utilizing serum ceruloplasmin and/or serum copper levels are less sensitive and specific in identifying patients with ALF-WD than other available tests. More readily available laboratory tests including alkaline phosphatase, bilirubin and serum...

  4. High frequency system project implementation plan. [Diagnostic recording system for Nevada Test Site

    Energy Technology Data Exchange (ETDEWEB)

    Moon, L. L.

    1976-03-12

    The High Frequency System is a new mobile, digital diagnostic recording system for use at the Nevada Test Site. Many different kinds of event data will be digitized in real-time by this system, and these data will be recorded and stored for later read-out and transmission to NADCEN. The hardware and software requirements of the High Frequency System are examined, and the parameters of the system are proposed.

  5. Comparison of rapid diagnostic tests to detect Mycobacterium avium subsp. paratuberculosis disseminated infection in bovine liver.

    Science.gov (United States)

    Zarei, Mehdi; Ghorbanpour, Masoud; Tajbakhsh, Samaneh; Mosavari, Nader

    2017-08-01

    Mycobacterium avium subsp. paratuberculosis (MAP) causes Johne's disease, a chronic enteritis in cattle and other domestic and wild ruminants. The presence of MAP in tissues other than intestines and associated lymph nodes, such as meat and liver, is a potential public health concern. In the present study, the relationship between the results of rapid diagnostic tests of the Johne's disease, such as serum ELISA, rectal scraping PCR, and acid-fast staining, and the presence of MAP in liver was evaluated. Blood, liver, and rectal scraping samples were collected from 200 slaughtered cattle with unknown Johne's disease status. ELISA was performed to determine the MAP antibody activity in the serum. Acid-fast staining was performed on rectal scraping samples, and PCR was performed on rectal scraping and liver samples. PCR-positive liver samples were used for mycobacterial culture. Overall, the results of this study demonstrated that MAP can be detected and cultured from liver of slaughtered cattle and rapid diagnostic tests of Johne's disease have limited value in detecting cattle with MAP infection in liver. These findings show that the presence of MAP in liver tissue may occur in cows with negative results for rapid diagnostic tests and vice versa. Hence, liver might represent another possible risk of human exposure to MAP. Given concerns about a potential zoonotic role for MAP, these results show the necessity to find new methods for detecting cattle with MAP disseminated infection.

  6. GAMBARAN PENGGUNAAN RAPID DIAGNOSTIC TEST PARASIT MALARIA DI DESA PASIRMUKTI KECAMATAN CINEAM KABUPATEN TASIKMALAYA

    Directory of Open Access Journals (Sweden)

    Hubullah Fuadzy

    2013-12-01

    Full Text Available Abstract. High mobility amongst mining workers, demanding officer of Cineam Public Health Center can perform rapid diagnosis to the workers. Nowadays, many techniques are developed to detect the early transmission of malaria, begins from the clinical to the molecular, one of that techniques are Rapid Diagnostic Tests (RDTs. This research has been conducted in the village of Pasirmukti district Cineam, Tasikmalaya in 2012. Objective of this paper is description RDT utilities as rapid diagnosing efforts on families who have family members as mine worker malaria endemic areas. Inclusion criteria for this study were family who have and do not have family members were working as workers in malaria-endemic areas at 2011 or 2012. Respondents were willing to participate in this study would be taken for examination RDT. Respondents were willing to participate in this study amounted to 256 people, and 5 of them positive Plasmodium malaria based on RDTs screening. Respondents who positive for malaria on RDTs test were 4 women with lower education background and work as a housewife, then a men with a background of secondary school education and are currently still as student. RDT is one of the malaria parasite tools which suitable for use in the Pasirmukti Village district Cineam - Tasikmalaya. However, keep in mind on how to storage and use in order to avoid errors both false-positive and false negatives test results.   Keywords: rapid diagnostic tests, malaria, Tasikmalaya Abstrak. Mobilitas yang tinggi penduduk Cineam  menuju wilayah pertambangan emas diluar pulau Jawa, menuntut tenaga kesehatan di Puskesmas Cineam dapat melakukan diagnosa dini penyakit malaria terhadap para pekerja tambang tersebut. Saat ini, banyak dikembangkan teknik untuk mendeteksi penularan penyakit malaria secara dini, mulai dari yang bersifat klinis hingga molekuler, diantaranya adalah Rapid Diagnostic Tests (RDTs. Untuk mengetahui gambaran pemanfaatan RDT di Cineam perlu

  7. Plasma Diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Zaveryaev, V [Kurchatov Institute, Moscow (Russian Federation); others, and

    2012-09-15

    The success in achieving peaceful fusion power depends on the ability to control a high temperature plasma, which is an object with unique properties, possibly the most complicated object created by humans. Over years of fusion research a new branch of science has been created, namely plasma diagnostics, which involves knowledge of almost all fields of physics, from electromagnetism to nuclear physics, and up-to-date progress in engineering and technology (materials, electronics, mathematical methods of data treatment). Historically, work on controlled fusion started with pulsed systems and accordingly the methods of plasma parameter measurement were first developed for short lived and dense plasmas. Magnetically confined hot plasmas require the creation of special experimental techniques for diagnostics. The diagnostic set is the most scientifically intensive part of a plasma device. During many years of research operation some scientific tasks have been solved while new ones arose. New tasks often require significant changes in the diagnostic system, which is thus a very flexible part of plasma machines. Diagnostic systems are designed to solve several tasks. As an example here are the diagnostic tasks for the International Thermonuclear Experimental Reactor - ITER: (1) Measurements for machine protection and basic control; (2) Measurements for advanced control; (3) Additional measurements for performance evaluation and physics. Every new plasma machine is a further step along the path to the main goal - controlled fusion - and nobody knows in advance what new phenomena will be met on the way. So in the planning of diagnostic construction we should keep in mind further system upgrading to meet possible new scientific and technical challenges. (author)

  8. Analysis of Frequency of Tests and Varying Feedback Delays in College Mathematics Achievement

    Science.gov (United States)

    Townsend, Neal R.; Wheatley, Grayson H.

    1975-01-01

    Sixteen beginning analytic geometry and calculus classes (442 students) followed eight testing regimes for one academic quarter. Three aptitude subgroups were identified in each class. Classes to which daily quizzes were given achieved significantly higher on a specially constructed test than those which had only a single midterm examination.…

  9. Diagnostic accuracy of the rapid urine lipoarabinomannan test for pulmonary tuberculosis among HIV-infected adults in Ghana-findings from the DETECT HIV-TB study

    DEFF Research Database (Denmark)

    Bjerrum, Stephanie; Kenu, Ernest; Lartey, Margaret

    2015-01-01

    BACKGROUND: Rapid diagnostic tests are urgently needed to mitigate HIV-associated tuberculosis (TB) mortality. We evaluated diagnostic accuracy of the rapid urine lipoarabinomannan (LAM) test for pulmonary TB and assessed the effect of a two-sample strategy. METHODS: HIV-infected adults eligible...

  10. A molecular diagnostic test for persistent Müllerian duct syndrome in miniature schnauzer dogs.

    Science.gov (United States)

    Pujar, S; Meyers-Wallen, V N

    2009-01-01

    In persistent Müllerian duct syndrome (PMDS), Müllerian ducts fail to regress in males during sexual differentiation. In the canine miniature schnauzer model, PMDS is caused by a C to T transition in exon 3 of the Müllerian inhibiting substance type II receptor (MISRII), which introduces a DdeI restriction site. Here we report a molecular diagnostic test for PMDS in the miniature schnauzer to identify affected dogs and carriers. As our test results suggest that the mutation is identical by descent in affected dogs of this breed, the test could be used to eliminate this mutation from the miniature schnauzer breed worldwide.

  11. Diagnostic accuracy of tests to detect hepatitis B surface antigen: a systematic review of the literature and meta-analysis

    Directory of Open Access Journals (Sweden)

    Ali Amini

    2017-11-01

    Full Text Available Abstract Background Chronic Hepatitis B Virus (HBV infection is characterised by the persistence of hepatitis B surface antigen (HBsAg. Expanding HBV diagnosis and treatment programmes into low resource settings will require high quality but inexpensive rapid diagnostic tests (RDTs in addition to laboratory-based enzyme immunoassays (EIAs to detect HBsAg. The purpose of this review is to assess the clinical accuracy of available diagnostic tests to detect HBsAg to inform recommendations on testing strategies in 2017 WHO hepatitis testing guidelines. Methods The systematic review was conducted according to the Preferred Reporting Items for Systematic Reviews and Meta-analyses (PRISMA guidelines using 9 databases. Two reviewers independently extracted data according to a pre-specified plan and evaluated study quality. Meta-analysis was performed. HBsAg diagnostic accuracy of rapid diagnostic tests (RDTs was compared to enzyme immunoassay (EIA and nucleic-acid test (NAT reference standards. Subanalyses were performed to determine accuracy among brands, HIV-status and specimen type. Results Of the 40 studies that met the inclusion criteria, 33 compared RDTs and/or EIAs against EIAs and 7 against NATs as reference standards. Thirty studies assessed diagnostic accuracy of 33 brands of RDTs in 23,716 individuals from 23 countries using EIA as the reference standard. The pooled sensitivity and specificity were 90.0% (95% CI: 89.1, 90.8 and 99.5% (95% CI: 99.4, 99.5 respectively, but accuracy varied widely among brands. Accuracy did not differ significantly whether serum, plasma, venous or capillary whole blood was used. Pooled sensitivity of RDTs in 5 studies of HIV-positive persons was lower at 72.3% (95% CI: 67.9, 76.4 compared to that in HIV-negative persons, but specificity remained high. Five studies evaluated 8 EIAs against a chemiluminescence immunoassay reference standard with a pooled sensitivity and specificity of 88.9% (95% CI: 87.0, 90.6 and

  12. Molecular diagnostic testing for primary biliary cholangitis.

    Science.gov (United States)

    Gatselis, Nikolaos K; Dalekos, George N

    2016-09-01

    A reliable liver autoimmune serology for the diagnosis of primary biliary cholangitis (PBC) is of particular importance. Recognition of patients at early stages and prompt treatment initiation may alter the outcome, slow progression, delays liver failure, and improves survival. In this review, we summarize and discuss the published data obtained from literature searches from PubMed and The National Library of Medicine (USA) and our own experience on the current and potential molecular based approaches to the diagnosis of PBC. Expert commentary: Standardization of liver diagnostic serology and clinical governance are two major points as antimitochondrial antibodies are the diagnostic hallmark of the disease and PBC-specific antinuclear antibodies could assist in the diagnosis and estimation of prognosis. New biomarkers such as novel autoantibodies, genetic polymorphisms, metabolomic profiling, micro-RNA and epigenetics may assist to the understanding, diagnosis and management of the disease.

  13. Achievements and Future Plans of CLIC Test Facilities

    CERN Document Server

    Braun, Hans Heinrich

    2001-01-01

    CTF2 was originally designed to demonstrate the feasibility of two-beam acceleration with high current drive beams and a string of 30 GHz CLIC accelerating structure prototypes (CAS). This goal was achieved in 1999 and the facility has since been modified to focus on high gradient testing of CAS's and 30 GHz single cell cavities (SCC). With these modifications, it is now possible to provide 30 GHz RF pulses of more than 150 MW and an adjustable pulselength from 3 to 15 ns. While the SCC results are promising, the testing of CAS's revealed problems of RF breakdown and related surface damage. As a consequence, a new R&D program has been launched to advance the understanding of RF breakdown processes, to improve surface properties, investigate new materials and to optimise the structure geometries of the CAS's. In parallel the construction of a new facility named CTF3 has started. CTF3 will mainly serve two purposes. The first is the demonstration of the CLIC drive beam generation scheme. CTF3 will acceler-a...

  14. Diagnostic evaluation of neck torsion test in objective examination in patients with vertigo and/or hearing impairment.

    Science.gov (United States)

    Niewiadomski, Piotr; Bielińska, Marzena; Pietkiewicz, Piotr; Olszewski, Jurek

    2017-10-30

    The aim of the study was to evaluate the neck torsion test in objective examinations of patients with vertigo and/or hearing loss. The study was conducted in 100 patients, including 54 women and 46 men aged 17-79 years, who were divided into two groups: I - 50 patients, including 30 women and 20 men aged 17-79 years (mean age 49.92 years) with dizziness and/or hearing impairments, and confirmed asymmetry of intracranial vessels, II - 50 patients - the control group, including 24 women and 26 men aged 20-71 years without dizziness and/or hearing disorders and without disturbance in the construction of intracranial vessels. For each patient, the following tests were carried out: subjective, objective otorhinolaryngological, Doppler ultrasound specifying the diameter of vertebral and carotid arteries and the velocity of blood flow in these vessels, audiological diagnostics, including the examination of latency of waves I, III, V of the auditory evoked potentials of the brain stem, otoneurological diagnostics with used the neck torsion test. It appears from the analysis of the material presented that the application of the neck torsion test in the Doppler ultrasound results in the fact that the difference in the mean systolic velocity of blood flow in vertebral artery is higher on the side opposite to the turning of the neck, and the increase in the average diastolic blood flow velocity in the vertebral artery on the side of the test being performed and its reduction on the opposite side in the study group, when compared to the control group. The value of the wave I, II, V latency in the ABR test during the neck torsion test is extended more in the study group than in the controls, on the side of the performed test. The performed neck torsion test in the VNG test increases the occurrence of both, square waves and nystagmus (much higher in the study group than in the controls). The application of the neck torsion test in the Doppler ultrasound, ABR and VNG test in

  15. Diagnostic evaluation of neck torsion test in objective examination in patients with vertigo and/or hearing-impairment.

    Science.gov (United States)

    Niewiadomski, Piotr; Bielińska, Marzena; Pietkiewicz, Piotr; Olszewski, Jurek

    2017-06-30

    The aim of the study was to evaluate the neck torsion test in objective examinations of patients with vertigo and/or hearing loss. The study was conducted in 100 patients, including 54 women and 46 men aged 17-79 years, who were divided into two groups: I - 50 patients, including 30 women and 20 men aged 17-79 years (mean age 49.92 years) with dizziness and/or hearing impairments, and confirmed asymmetry of intracranial vessels, II - 50 patients - control group, including 24 women and 26 men aged 20-71 years without dizziness and/or hearing disorders and without disturbance in the construction of intracranial vessels. For each patient, the following tests were carried out: subjective, objective otorhinolaryngological, Doppler ultrasound specifying diameter of vertebral and carotid arteries and the velocity of blood flow in these vessels, audiological diagnostics, including the examination of latency of waves I, III, V of the auditory evoked potentials of the brain stem, otoneurological diagnostics with used the neck torsion test. It appears from the analysis of the material presented that the application of the neck torsion test in the Doppler ultrasound results in the fact that the difference in the mean systolic velocity of blood flow in vertebral artery is higher on the side opposite to the turning of the neck, and the increase in the average diastolic blood flow velocity in the vertebral artery on the side of the test being performed and its reduction on the opposite side in the study group, when compared to the control group. The value of the wave I, II, V latency in the ABR test during the neck torsion test is extended more in the study group than in the controls, on the side of the performed test. The performed neck torsion test in the VNG test increases the occurrence of both, square waves and nystagmus (much higher in the study group than in the controls). Conclussion. The application of the neck torsion test in the Doppler ultrasound, ABR and VNG test in

  16. Effectiveness of a Test-Taking Strategy on Achievement in Essay Tests for Students with Learning Disabilities

    Science.gov (United States)

    Therrien, William J.; Hughes, Charles; Kapelski, Cory; Mokhtari, Kouider

    2009-01-01

    Research was conducted to ascertain if an essay-writing strategy was effective at improving the achievement on essay tests for 7th- and 8th-grade students with reading and writing disabilities. Students were assigned via a stratified random sample to treatment or control group. Student scores were also compared to students without learning…

  17. Mental Abilities and School Achievement: A Test of a Mediation Hypothesis

    Science.gov (United States)

    Vock, Miriam; Preckel, Franzis; Holling, Heinz

    2011-01-01

    This study analyzes the interplay of four cognitive abilities--reasoning, divergent thinking, mental speed, and short-term memory--and their impact on academic achievement in school in a sample of adolescents in grades seven to 10 (N = 1135). Based on information processing approaches to intelligence, we tested a mediation hypothesis, which states…

  18. Irradiation tests of radiation resistance optical fibers for fusion diagnostic application

    Science.gov (United States)

    Kakuta, Tsunemi; Shikama, Tatsuo; Nishitani, Takeo; Yamamoto, Shin; Nagata, Shinji; Tsuchiya, Bun; Toh, Kentaro; Hori, Junichi

    2002-11-01

    To promote development of radiation-resistant core optical fibers, the ITER-EDA (International Thermonuclear Experimental Reactor-Engineering Design Activity) recommended carrying out international round-robin irradiation tests of optical fibers to establish a reliable database for their applications in the ITER plasma diagnostics. Ten developed optical fibers were irradiation-tested in a Co-60 gamma cell, a Japan Materials Testing Reactor (JMTR). Also, some of them were irradiation tested in a fast neutron irradiation facility of FNS (Fast Neutron Source), especially to study temperature dependence of neutron-associated irradiation effects. Included were several Japanese fluorine doped fibers and one Japanese standard fiber (purified and undoped silica core), as well as seven Russian fibers. Some of Russian fibers were drawn by Japanese manufactures from Russian made pre-form rods to study effects of manufacturing processes to radiation resistant properties. The present paper will describe behaviors of growth of radiation-induced optical transmission loss in the wavelength range of 350-1750nm. Results indicate that role of displacement damages by fast neutrons are very important in introducing permanent optical transmission loss. Spectra of optical transmission loss in visible range will depend on irradiation temperatures and material parameters of optical fibers.

  19. Socioeconomic Status of Parents and the Achievement of Children on Readiness for School Tests

    Directory of Open Access Journals (Sweden)

    Anela Hasanagic

    2015-07-01

    Full Text Available Socioeconomic status is often determined like the academic background of parents, and it can be determined like the place of living, village or town, city, as well. Socioeconomic status is an important factor in many aspects of living as in academic achievement as well. Problem in this research paper was to examine whether there are differences between children from different socio-economic status (level of education of parents and between children from villages and towns, on Readiness for school tests. The sample was constituted 296 kids, half from villages, and half from towns in Bosnia and Herzegovina. Tests that were used are: Differences test, Similarities test, Numerical test, Trace test, Knowledge Test, Questionnaire for measuring socio-emotional maturity, and Goodenough's Draw-a-Man Test. Results show that there are statistically significant differences between children from different socio-economic background. Children whose parents are low educated have lower results on Readiness for school test, comparing with children whose parents have finished high school or university level. There were differences between village and town children only on Goodenough's Draw-a-Man Test and on Similarity test, while on other instruments place of living was not important factor for achievement on Readiness for School Test.

  20. Neutronics analysis for integration of ITER diagnostics port EP10

    Energy Technology Data Exchange (ETDEWEB)

    Colling, Bethany, E-mail: bethany.colling@ccfe.ac.uk [Culham Centre for Fusion Energy, Culham Science Centre, Abingdon, Oxon OX14 3DB (United Kingdom); Department of Engineering, Lancaster University, Lancashire LA1 4YR (United Kingdom); Eade, Tim [Culham Centre for Fusion Energy, Culham Science Centre, Abingdon, Oxon OX14 3DB (United Kingdom); Joyce, Malcolm J. [Department of Engineering, Lancaster University, Lancashire LA1 4YR (United Kingdom); Pampin, Raul; Seyvet, Fabien [Fusion for Energy, Josep Pla 2, Torres Diagonal Litoral B3, 08019 Barcelona (Spain); Turner, Andrew [Culham Centre for Fusion Energy, Culham Science Centre, Abingdon, Oxon OX14 3DB (United Kingdom); Udintsev, Victor [ITER Organization, Route de Vinon-sur-Verdon, CS 90 046, 13067 St. Paul Lez Durance Cedex (France)

    2016-11-01

    Shutdown dose rate calculations have been performed on an integrated ITER C-lite neutronics model with equatorial port 10. A ‘fully shielded’ configuration, optimised for a given set of diagnostic designs (i.e. shielding in all available space within the port plug drawers), results in a shutdown dose rate in the port interspace, from the activation of materials comprising equatorial port 10, in excess of 2000 μSv/h. Achieving dose rates of 100 μSv/h or less, as required in areas where hands-on maintenance can be performed, in the port interspace region will be challenging. A combination of methods will need to be implemented, such as reducing mass and/or the use of reduced activation steel in the port interspace, optimisation of the diagnostic designs and shielding of the port interspace floor. Further analysis is required to test these options and the ongoing design optimisation of the EP10 diagnostic systems.

  1. Adoption of rapid diagnostic tests for the diagnosis of malaria, a preliminary analysis of the Global Fund program data, 2005 to 2010.

    Directory of Open Access Journals (Sweden)

    Jinkou Zhao

    Full Text Available The World Health Organization Guidelines for the Treatment of Malaria, in 2006 and 2010, recommend parasitological confirmation of malaria before commencing treatment. Although microscopy has been the mainstay of malaria diagnostics, the magnitude of diagnostic scale up required to follow the Guidelines suggests that rapid diagnostic tests (RDTs will be a large component. This study analyzes the adoption of rapid diagnostic testing in malaria programs supported by the Global Fund to fight AIDS, Tuberculosis and Malaria (Global Fund, the leading international funder of malaria control globally.We analyzed, for the period 2005 to 2010, Global Fund programmatic data for 81 countries on the quantity of RDTs planned; actual quantities of RDTs and artemisinin-based combination treatments (ACTs procured in 2009 and 2010; RDT-related activities including RDTs distributed, RDTs used, total diagnostic tests including RDTs and microscopy performed, health facilities equipped with RDTs; personnel trained to perform rapid diagnostic malaria test; and grant budgets allocated to malaria diagnosis. In 2010, diagnosis accounted for 5.2% of malaria grant budget. From 2005 to 2010, the procurement plans include148 million RDTs through 96 malaria grants in 81 countries. Around 115 million parasitological tests, including RDTs, had reportedly been performed from 2005 to 2010. Over this period, 123,132 health facilities were equipped with RDTs and 137,140 health personnel had been trained to perform RDT examinations. In 2009 and 2010, 41 million RDTs and 136 million ACTs were purchased. The ratio of procured RDTs to ACTs was 0.26 in 2009 and 0.34 in 2010.Global Fund financing has enabled 81 malaria-endemic countries to adopt WHO guidelines by investing in RDTs for malaria diagnosis, thereby helping improve case management of acute febrile illness in children. However, roll-out of parasitological diagnosis lags behind the roll-out of ACT-based treatment, and will

  2. Diagnostic accuracy of the Rivalta test for feline infectious peritonitis.

    Science.gov (United States)

    Fischer, Yvonne; Sauter-Louis, Carola; Hartmann, Katrin

    2012-12-01

    The Rivalta test has been used routinely in Europe to diagnose feline infectious peritonitis (FIP) in cats with effusions, but its diagnostic accuracy is uncertain. The objectives of this study were to calculate sensitivity, specificity, and positive (PPV) and negative (NPV) predictive values of the Rivalta test for FIP and to identify correlations between a positive Rivalta test and variables measured in effusion fluid and peripheral blood. In this retrospective study, medical records of cats with effusions were reviewed, and cats with conclusive results for the Rivalta test were included. The prevalence of FIP in this population was determined, and sensitivity, specificity, and PPV and NPV of the Rivalta test were calculated. Variables measured in effusion fluid and peripheral blood were compared between cats that had positive or negative Rivalta tests using the Mann-Whitney U-test and multivariate analysis. Of 851 cats with effusions, 782 had conclusively positive or negative results for the Rivalta test. A definitive final diagnosis was made in 497 of these cats. Prevalence of FIP in cats with effusion and a conclusive Rivalta test result was 34.6%. The Rivalta test had a sensitivity of 91.3%, specificity of 65.5%, PPV of 58.4%, and NPV of 93.4% for the diagnosis of FIP. These values increased when cats with lymphoma or bacterial infections were excluded, or when only cats ≤ 2 years were considered. Increased effusion cholesterol concentration and specific gravity as well as decreased serum albumin:globulin ratio and hyperbilirubinemia were positively correlated with positive Rivalta test results. Sensitivity, specificity, and PPV of the Rivalta test for the diagnosis of FIP were lower than previously reported except when used in young cats. The components in effusions that lead to a positive Rivalta test remain unknown, but the positivity is not simply related to high total protein concentration. © 2012 American Society for Veterinary Clinical Pathology.

  3. Early Improvement As a Predictor of Later Response to Antipsychotics in Schizophrenia: A Diagnostic Test Review

    NARCIS (Netherlands)

    Samara, Myrto T.; Leucht, Claudia; Leeflang, Mariska M.; Anghelescu, Ion-George; Chung, Young-Chul; Crespo-Facorro, Benedicto; Elkis, Helio; Hatta, Kotaro; Giegling, Ina; Kane, John M.; Kayo, Monica; Lambert, Martin; Lin, Ching-Hua; Möller, Hans-Jürgen; Pelayo-Terán, José María; Riedel, Michael; Rujescu, Dan; Schimmelmann, Benno G.; Serretti, Alessandro; Correll, Christoph U.; Leucht, Stefan

    2015-01-01

    How long clinicians should wait before considering an antipsychotic ineffective and changing treatment in schizophrenia is an unresolved clinical question. Guidelines differ substantially in this regard. The authors conducted a diagnostic test meta-analysis using mostly individual patient data to

  4. Achievement-Based Rewards and Intrinsic Motivation: A Test of Cognitive Mediators

    Science.gov (United States)

    Cameron, Judy; Pierce, W. David; Banko, Katherine M.; Gear, Amber

    2005-01-01

    This study assessed how rewards impacted intrinsic motivation when students were rewarded for achievement while learning an activity, for performing at a specific level on a test, or for both. Undergraduate university students engaged in a problem-solving activity. The design was a 2 * 2 factorial with 2 levels of reward in a learning phase…

  5. 42 CFR 493.833 - Condition: Diagnostic immunology.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 5 2010-10-01 2010-10-01 false Condition: Diagnostic immunology. 493.833 Section..., Or Any Combination of These Tests § 493.833 Condition: Diagnostic immunology. The specialty of diagnostic immunology includes for purposes of proficiency testing the subspecialties of syphilis serology...

  6. Molecular evidence of malaria and zoonotic diseases among rapid diagnostic test-negative febrile patients in low-transmission season, Mali

    DEFF Research Database (Denmark)

    Touré, Mahamoudou; Petersen, Pelle T; Bathily, Sidy N'd

    2017-01-01

    From November to December 2012 in Sélingué-Mali, blood samples from 88 febrile patients who tested negative by malaria Paracheck (®) rapid diagnostic tests (RDTs) were used to assess the presence of sub-RDT Plasmodium falciparum as well as Borrelia, Coxiella burnetii, and Babesia applying molecular...... tools. Plasmodium sp. was present among 57 (60.2%) of the 88 malaria RDT-negative patients, whereas the prevalence of Borrelia, C. burnetii, and Babesia were 3.4% (N = 3), 1.1% (N = 1), and 0.0%, respectively. The additional diagnostic use of polymerase chain reaction (PCR) identified a high proportion...

  7. New Exercise-Dipyridamole Combined Test for Nuclear Cardiology in Insufficient Effort: Appropriate Diagnostic Sensitivity Keeping Exercise Prognosis

    Energy Technology Data Exchange (ETDEWEB)

    Cortinas, Inés Vidal, E-mail: invi@montevideo.com.uy; Beretta, Mario; Alonso, Omar; Mut, Fernando [Departamento de Medicina Nuclear do Hospital ‘Asociación Española’, Br. Artigas 1515, Montevideo (Uruguay)

    2015-08-15

    Myocardial perfusion scintigraphy (MPS) in patients not reaching 85% of the maximum predicted heart rate (MPHR) has reduced sensitivity. In an attempt to maintain diagnostic sensitivity without losing functional exercise data, a new exercise and dipyridamole combined protocol (EDCP) was developed. Our aim was to evaluate the feasibility and safety of this protocol and to compare its diagnostic sensitivity against standard exercise and dipyridamole protocols. In patients not reaching a sufficient exercise (SE) test and with no contraindications, 0.56 mg/kg of dipyridamole were IV administered over 1 minute simultaneously with exercise, followed by 99mTc-MIBI injection. Of 155 patients, 41 had MPS with EDCP, 47 had a SE test (≥ 85% MPHR) and 67 underwent the dipyridamole alone test (DIP). They all underwent coronary angiography within 3 months. The three stress methods for diagnosis of coronary lesions had their sensitivity compared. For stenosis ≥ 70%, EDCP yielded 97% sensitivity, SE 90% and DIP 95% (p = 0.43). For lesions ≥ 50%, the sensitivities were 94%, 88% and 95%, respectively (p = 0.35). Side effects of EDCP were present in only 12% of the patients, significantly less than with DIP (p < 0.001). The proposed combined protocol is a valid and safe method that yields adequate diagnostic sensitivity, keeping exercise prognostic information in patients unable to reach target heart rate, with fewer side effects than the DIP.

  8. Problem of presently available diagnostic tests for Zika virus infection: View from Thailand

    Institute of Scientific and Technical Information of China (English)

    Beuy Joob; Viroj Wiwanitkit

    2016-01-01

    Dear Editor,Zika virus infection is the present global issue due to the finding of occurrence of congenital defect relating to this infection[1,2].The disease is a dengue-like infection,hence,it is well-known that the missed and under diagnosis is possible[1,2].However,the big concern is on the reliability of the presently available diagnostic tests for diagnosing Zika virus infection.Here,the authors appraise on previous published

  9. Comparative evaluation of two rapid field tests for malaria diagnosis: Partec Rapid Malaria Test® and Binax Now® Malaria Rapid Diagnostic Test.

    Science.gov (United States)

    Nkrumah, Bernard; Acquah, Samuel Ek; Ibrahim, Lukeman; May, Juergen; Brattig, Norbert; Tannich, Egbert; Nguah, Samuel Blay; Adu-Sarkodie, Yaw; Huenger, Frank

    2011-05-23

    About 90% of all malaria deaths in sub-Saharan Africa occur in children under five years. Fast and reliable diagnosis of malaria requires confirmation of the presence of malaria parasites in the blood of patients with fever or history suggestive of malaria; hence a prompt and accurate diagnosis of malaria is the key to effective disease management. Confirmation of malaria infection requires the availability of a rapid, sensitive, and specific testing at an affordable cost. We compared two recent methods (the novel Partec Rapid Malaria Test® (PT) and the Binax Now® Malaria Rapid Diagnostic Test (BN RDT) with the conventional Giemsa stain microscopy (GM) for the diagnosis of malaria among children in a clinical laboratory of a hospital in a rural endemic area of Ghana. Blood samples were collected from 263 children admitted with fever or a history of fever to the pediatric clinic of the Agogo Presbyterian Hospital. The three different test methods PT, BN RDT and GM were performed independently by well trained and competent laboratory staff to assess the presence of malaria parasites. Results were analyzed and compared using GM as the reference standard. In 107 (40.7%) of 263 study participants, Plasmodium sp. was detected by GM. PT and BN RDT showed positive results in 111 (42.2%) and 114 (43.4%), respectively. Compared to GM reference standard, the sensitivities of the PT and BN RDT were 100% (95% CI: 96.6-100) and 97.2% (95% CI: 92.0-99.4), respectively, specificities were 97.4% (95% CI: 93.6-99.3) and 93.6% (95% CI: 88.5-96.9), respectively. There was a strong agreement (kappa) between the applied test methods (GM vs PT: 0.97; p < 0.001 and GM vs BN RDT: 0.90; p < 0.001). The average turnaround time per tests was 17 minutes. In this study two rapid malaria tests, PT and BN RDT, demonstrated a good quality of their performance compared to conventional GM. Both methods require little training, have short turnaround times, are applicable as well as affordable and

  10. Array-on-a-disk? How Blu-ray technology can be applied to molecular diagnostics.

    Science.gov (United States)

    Morais, Sergi; Tortajada-Genaro, Luis; Maquieira, Angel

    2014-09-01

    This editorial comments on the balance and perspectives of compact disk technology applied to molecular diagnostics. The development of sensitive, rapid and multiplex assays using Blu-ray technology for the determination of biomarkers, drug allergens, pathogens and detection of infections would have a direct impact on diagnostics. Effective tests for use in clinical, environmental and food applications require versatile and low-cost platforms as well as cost-effective detectors. Blu-ray technology accomplishes those requirements and advances on the concept of high density arrays for massive screening to achieve the demands of point of care or in situ analysis.

  11. Safety of a rapid diagnostic protocol with accelerated stress testing.

    Science.gov (United States)

    Soremekun, Olan A; Hamedani, Azita; Shofer, Frances S; O'Conor, Katie J; Svenson, James; Hollander, Judd E

    2014-02-01

    Most patients at low to intermediate risk for an acute coronary syndrome (ACS) receive a 12- to 24-hour "rule out." Recently, trials have found that a coronary computed tomographic angiography-based strategy is more efficient. If stress testing were performed within the same time frame as coronary computed tomographic angiography, the 2 strategies would be more similar. We tested the hypothesis that stress testing can safely be performed within several hours of presentation. We performed a retrospective cohort study of patients presenting to a university hospital from January 1, 2009, to December 31, 2011, with potential ACS. Patients placed in a clinical pathway that performed stress testing after 2 negative troponin values 2 hours apart were included. We excluded patients with ST-elevation myocardial infarction or with an elevated initial troponin. The main outcome was safety of immediate stress testing defined as the absence of death or acute myocardial infarction (defined as elevated troponin within 24 hours after the test). A total of 856 patients who presented with potential ACS were enrolled in the clinical pathway and included in this study. Patients had a median age of 55.0 (interquartile range, 48-62) years. Chest pain was the chief concern in 86%, and pain was present on arrival in 73% of the patients. There were no complications observed during the stress test. There were 0 deaths (95% confidence interval, 0%-0.46%) and 4 acute myocardial infarctions within 24 hours (0.5%; 95% confidence interval, 0.14%-1.27%). The peak troponins were small (0.06, 0.07, 0.07, and 0.19 ng/mL). Patients who present to the ED with potential ACS can safely undergo a rapid diagnostic protocol with stress testing. © 2013.

  12. Diagnostic and prognostic utility of an inexpensive rapid on site malaria diagnostic test (ParaHIT f) among ethnic tribal population in areas of high, low and no transmission in central India

    Science.gov (United States)

    Singh, Neeru; Mishra, AK; Shukla, MM; Chand, SK; Bharti, Praveen Kumar

    2005-01-01

    Background Malaria presents a diagnostic challenge in most tropical countries. Rapid detection of the malaria parasite and early treatment of infection still remain the most important goals of disease management. Therefore, performance characteristics of the new indigenous ParaHIT f test (Span diagnostic Ltd, Surat, India) was determined among ethnic tribal population in four districts of different transmission potential in central India to assess whether this rapid diagnostic test (RDT) could be widely applied as a diagnostic tool to control malaria. Beyond diagnosis, the logical utilization of RDTs is to monitor treatment outcome. Methods A finger prick blood sample was collected from each clinically suspected case of malaria to prepare blood smear and for testing with the RDT after taking informed consent. The blood smears were read by an experienced technician blinded to the RDT results and clinical status of the subjects. The figures for specificity, sensitivity, accuracy and predictive values were calculated using microscopy as gold standard. Results The prevalence of malaria infection estimated by RDT in parallel with microscopy provide evidence of the type of high, low or no transmission in the study area. Analysis revealed (pooled data of all four epidemiological settings) that overall sensitivity, specificity and accuracy of the RDT were >90% in areas of different endemicity. While, RDT is useful to confirm the diagnosis of new symptomatic cases of suspected P. falciparum infection, the persistence of parasite antigen leading to false positives even after clearance of asexual parasitaemia has limited its utility as a prognostic tool. Conclusion The study showed that the ParaHIT f test was easy to use, reliable and cheap. Thus this RDT is an appropriate test for the use in the field by paramedical staff when laboratory facilities are not available and thus likely to contribute greatly to an effective control of malaria in resource poor countries. PMID

  13. Hypersensitivity reactions to metallic implants-diagnostic algorithm and suggested patch test series for clinical use

    DEFF Research Database (Denmark)

    Schalock, Peter C; Menné, Torkil; Johansen, Jeanne D

    2011-01-01

    Cutaneous and systemic hypersensitivity reactions to implanted metals are challenging to evaluate and treat. Although they are uncommon, they do exist, and require appropriate and complete evaluation. This review summarizes the evidence regarding evaluation tools, especially patch and lymphocyte...... transformation tests, for hypersensitivity reactions to implanted metal devices. Patch test evaluation is the gold standard for metal hypersensitivity, although the results may be subjective. Regarding pre-implant testing, those patients with a reported history of metal dermatitis should be evaluated by patch...... testing. Those without a history of dermatitis should not be tested unless considerable concern exists. Regarding post-implant testing, a subset of patients with metal hypersensitivity may develop cutaneous or systemic reactions to implanted metals following implant. For symptomatic patients, a diagnostic...

  14. PageFocus: Using paradata to detect and prevent cheating on online achievement tests.

    Science.gov (United States)

    Diedenhofen, Birk; Musch, Jochen

    2017-08-01

    Cheating threatens the validity of unproctored online achievement tests. To address this problem, we developed PageFocus, a JavaScript that detects when participants abandon test pages by switching to another window or browser tab. In a first study, we aimed at testing whether PageFocus could detect and prevent cheating. We asked 115 lab and 186 online participants to complete a knowledge test comprising items that were difficult to answer but easy to look up on the Internet. Half of the participants were invited to look up the solutions, which significantly increased their test scores. The PageFocus script detected test takers who abandoned the test page with very high sensitivity and specificity, and successfully reduced cheating by generating a popup message that asked participants not to cheat. In a second study, 510 online participants completed a knowledge test comprising items that could easily be looked up and a reasoning task involving matrices that were impossible to look up. In a first group, a performance-related monetary reward was promised to the top scorers; in a second group, participants took part in a lottery that provided performance-unrelated rewards; and in a third group, no incentive was offered. PageFocus revealed that participants cheated more when performance-related incentives were offered. As expected, however, this effect was limited to items that could easily be looked up. We recommend that PageFocus be routinely employed to detect and prevent cheating on online achievement tests.

  15. Exploration of analysis methods for diagnostic imaging tests: problems with ROC AUC and confidence scores in CT colonography.

    Science.gov (United States)

    Mallett, Susan; Halligan, Steve; Collins, Gary S; Altman, Doug G

    2014-01-01

    Different methods of evaluating diagnostic performance when comparing diagnostic tests may lead to different results. We compared two such approaches, sensitivity and specificity with area under the Receiver Operating Characteristic Curve (ROC AUC) for the evaluation of CT colonography for the detection of polyps, either with or without computer assisted detection. In a multireader multicase study of 10 readers and 107 cases we compared sensitivity and specificity, using radiological reporting of the presence or absence of polyps, to ROC AUC calculated from confidence scores concerning the presence of polyps. Both methods were assessed against a reference standard. Here we focus on five readers, selected to illustrate issues in design and analysis. We compared diagnostic measures within readers, showing that differences in results are due to statistical methods. Reader performance varied widely depending on whether sensitivity and specificity or ROC AUC was used. There were problems using confidence scores; in assigning scores to all cases; in use of zero scores when no polyps were identified; the bimodal non-normal distribution of scores; fitting ROC curves due to extrapolation beyond the study data; and the undue influence of a few false positive results. Variation due to use of different ROC methods exceeded differences between test results for ROC AUC. The confidence scores recorded in our study violated many assumptions of ROC AUC methods, rendering these methods inappropriate. The problems we identified will apply to other detection studies using confidence scores. We found sensitivity and specificity were a more reliable and clinically appropriate method to compare diagnostic tests.

  16. ACER Chemistry Test Item Collection (ACER CHEMTIC Year 12 Supplement).

    Science.gov (United States)

    Australian Council for Educational Research, Hawthorn.

    This publication contains 317 multiple-choice chemistry test items related to topics covered in the Victorian (Australia) Year 12 chemistry course. It allows teachers access to a range of items suitable for diagnostic and achievement purposes, supplementing the ACER Chemistry Test Item Collection--Year 12 (CHEMTIC). The topics covered are: organic…

  17. Comparative evaluation of bivalent malaria rapid diagnostic tests versus traditional methods in field with special reference to heat stability testing in Central India.

    Directory of Open Access Journals (Sweden)

    Neeru Singh

    Full Text Available Malaria presents a diagnostic challenge in areas where both Plasmodium falciparum and P.vivax are co-endemic. Bivalent Rapid Diagnostic tests (RDTs showed promise as diagnostic tools for P.falciparum and P.vivax. To assist national malaria control programme in the selection of RDTs, commercially available seven malaria RDTs were evaluated in terms of their performance with special reference to heat stability.This study was undertaken in four forested districts of central India (July, 2011- March, 2012. All RDTs were tested simultaneously in field along with microscopy as gold standard. These RDTs were stored in their original packing at 25°C before transport to the field or they were stored at 35°C and 45°C upto 100 days for testing the performance of RDTs at high temperature. In all 2841 patients with fever were screened for malaria of which 26% were positive for P.falciparum, and 17% for P.vivax. The highest sensitivity of any RDT for P.falciparum was 98% (95% CI; 95.9-98.8 and lowest sensitivity was 76% (95% CI; 71.7-79.6. For P.vivax highest and lowest sensitivity for any RDT was 80% (95% CI; 94.9 - 83.9 and 20% (95% CI; 15.6-24.5 respectively. Heat stability experiments showed that most RDTs for P.falciparum showed high sensitivity at 45°C upto 90 days. While for P.vivax only two RDTs maintained good sensitivity upto day 90 when compared with RDTs kept at room temperature. Agreement between observers was excellent for positive and negative readings for both P.falciparum and P.vivax (Kappa >0.6-0.9.This is first field evaluation of RDTs regarding their temperature stability. Although RDTs are useful as diagnostic tool for P.falciparum and P.vivax even at high temperature, the quality of RDTs should be regulated and monitored more closely.

  18. Comorbidity negatively influences the outcomes of diagnostic tests for musculoskeletal pain in the orofacial region.

    Science.gov (United States)

    Koutris, Michail; Visscher, Corine M; Lobbezoo, Frank; Naeije, Machiel

    2013-06-01

    The aim of this study was to investigate whether diagnostic tests for musculoskeletal pain in the orofacial region [temporomandibular disorder (TMD) pain] are influenced by the presence of comorbid conditions, and to determine whether this influence decreases when the presence of "familiar pain" is used as outcome measure. In total, 117 patients (35 men, 82 women; 75 TMD-pain patients, 42 pain-free patients; mean age ± SD = 42.94 ± 14.17 years) were examined with palpation tests and dynamic/static tests. After each test, they were asked whether any pain was provoked and whether this pain response was familiar or not. For four clinical outcome measures (pain on palpation, familiar pain on palpation, pain on dynamic/static tests, and familiar pain on dynamic/static tests), multiple logistic regression analyses were performed with the presence of TMD pain as the primary predictor and regional (neck/shoulder) pain, widespread pain, depression, and somatization as comorbid factors. Pain on palpation was not associated with the primary predictor but with regional pain [P = 0.02, odds ratio (OR) = 4.59] and somatization (P = 0.011, OR = 8.47), whereas familiar pain on palpation was associated with the primary predictor (P = 0.003, OR = 5.23), but also with widespread pain (P = 0.001, OR = 2.02). Pain on dynamic/static tests was associated with the primary predictor (P pain on dynamic/static tests was only associated with the primary predictor (P diagnostic tests are negatively influenced by the presence of comorbidity. This influence decreases when the presence of familiar pain is used as outcome measure. Copyright © 2013 International Association for the Study of Pain. Published by Elsevier B.V. All rights reserved.

  19. Tumor specific lung cancer diagnostics with multiplexed FRET immunoassays

    Science.gov (United States)

    Geißler, D.; Hill, D.; Löhmannsröben, H.-G.; Thomas, E.; Lavigne, A.; Darbouret, B.; Bois, E.; Charbonnière, L. J.; Ziessel, R. F.; Hildebrandt, N.

    2010-02-01

    An optical multiplexed homogeneous (liquid phase) immunoassay based on FRET from a terbium complex to eight different fluorescent dyes is presented. We achieved highly sensitive parallel detection of four different lung cancer specific tumor markers (CEA, NSE, SCC and CYFRA21-1) within a single assay and show a proof-of-principle for 5- fold multiplexing. The method is well suited for fast and low-cost miniaturized point-of-care testing as well as for highthroughput screening in a broad range of in-vitro diagnostic applications.

  20. 42 CFR 493.921 - Diagnostic immunology.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 5 2010-10-01 2010-10-01 false Diagnostic immunology. 493.921 Section 493.921... Testing Proficiency Testing Programs by Specialty and Subspecialty § 493.921 Diagnostic immunology. The subspecialties under the specialty of immunology for which a program may offer proficiency testing are syphilis...

  1. Diagnostic Value of ELISA Tests for the Detection of Specific Antibodies in Cats and Rabbits with Dermatophytosis

    Directory of Open Access Journals (Sweden)

    Marinka Drobnič-Košorok

    2002-01-01

    Full Text Available Two indirect ELISA tests developed for the detection of specific IgG in cats and rabbits, infected with M. canis and T. mentagrophytes, respectively, were evaluated and compared. The levels of specific antibodies were determined in sera of 20 cats and 25 rabbits naturally infected with M. canis and T. mentagrophytes, respectively. Infection was confirmed by the results of fungal culture. Blood samples from 12 cats and 17 rabbits, previously unexposed to dermatophytes, served as negative controls. A significant increase in the level of specific antibodies in groups of infected animals was demonstrated. Sensitivity, specificity and predictive values of a positive and a negative test were determined to evaluate the diagnostic potential. ELISA for the detection of specific antibodies in cats infected with M. canis (ELISA-cats test exhibited 75.0 % of sensitivity at 91.7 % of specificity, whereas the test for the detection of specific antibodies in rabbits, infected with T. mentagrophytes (ELISA-rabbits test is highly sensitive (96.0 % and highly specific (94.1 %, confirming its encouraging diagnostic potential. The cross-reactivity of fungal antigens was tested by performing the assays with antigens M. canis, T. mentagrophytes, M. pachydermatis and A. fumigatus. There were no significant indications of cross-reactions in the test T. mentagrophytes-rabbits, whereas strong cross-reaction between dermatophyte antigens was observed in the test M. canis-cats.

  2. Battery Test Facility- Electrochemical Analysis and Diagnostics Laboratory

    Data.gov (United States)

    Federal Laboratory Consortium — The Electrochemical Analysis and Diagnostics Laboratory (EADL) provides battery developers with reliable, independent, and unbiased performance evaluations of their...

  3. International consensus diagnostic criteria for neuromyelitis optica spectrum disorders

    Science.gov (United States)

    Banwell, Brenda; Bennett, Jeffrey L.; Cabre, Philippe; Carroll, William; Chitnis, Tanuja; de Seze, Jérôme; Fujihara, Kazuo; Greenberg, Benjamin; Jacob, Anu; Jarius, Sven; Lana-Peixoto, Marco; Levy, Michael; Simon, Jack H.; Tenembaum, Silvia; Traboulsee, Anthony L.; Waters, Patrick; Wellik, Kay E.

    2015-01-01

    Neuromyelitis optica (NMO) is an inflammatory CNS syndrome distinct from multiple sclerosis (MS) that is associated with serum aquaporin-4 immunoglobulin G antibodies (AQP4-IgG). Prior NMO diagnostic criteria required optic nerve and spinal cord involvement but more restricted or more extensive CNS involvement may occur. The International Panel for NMO Diagnosis (IPND) was convened to develop revised diagnostic criteria using systematic literature reviews and electronic surveys to facilitate consensus. The new nomenclature defines the unifying term NMO spectrum disorders (NMOSD), which is stratified further by serologic testing (NMOSD with or without AQP4-IgG). The core clinical characteristics required for patients with NMOSD with AQP4-IgG include clinical syndromes or MRI findings related to optic nerve, spinal cord, area postrema, other brainstem, diencephalic, or cerebral presentations. More stringent clinical criteria, with additional neuroimaging findings, are required for diagnosis of NMOSD without AQP4-IgG or when serologic testing is unavailable. The IPND also proposed validation strategies and achieved consensus on pediatric NMOSD diagnosis and the concepts of monophasic NMOSD and opticospinal MS. PMID:26092914

  4. Informativity of proteinograms as a clinical-diagnostic test at dispoteinemia in the age aspect

    Directory of Open Access Journals (Sweden)

    R. F. Yeriomenko

    2017-02-01

    Full Text Available The article analyzed dates of the usefulness of proteinograms as a clinical diagnostic test at dysproteinemia in age aspect. Established that proteinograms has  differences that depending on age, so these aspects should be considered in the diagnosis of certain pathological conditions in different age groups. Studying of children’s proteinograms in various pathological conditions indicates the appropriate changes in the fractional part of albumin and globulin, that characterized the development of inflammation and destruction of connective tissue. Besides diagnostic tests that help in the diagnosis, determine the stage of disease and the effectiveness of therapy is to study proteins "acute phase" and rheumatoid factor. Established the feasibility of proteinograms on the studying of dysproteinemia in different pathological conditions in adult age. It is found correlation between changes in protein fractions and stage of pathological process in connective tissue diseases (rheumatoid arthritis and systemic lupus erythema. At skin diseases, urinary, respiratory and hepatobiliary systems were recorded proteinograms changes depending on the damage of a system. Analysis of the results allows more accurate founded the diagnosis, determine the stage of the pathological process and evaluate the effectiveness of the pharmacotherapy.

  5. Comparative analysis of diagnostic performance, feasibility and cost of different test-methods for thyroid nodules with indeterminate cytology.

    Science.gov (United States)

    Sciacchitano, Salvatore; Lavra, Luca; Ulivieri, Alessandra; Magi, Fiorenza; De Francesco, Gian Paolo; Bellotti, Carlo; Salehi, Leila B; Trovato, Maria; Drago, Carlo; Bartolazzi, Armando

    2017-07-25

    Since it is impossible to recognize malignancy at fine needle aspiration (FNA) cytology in indeterminate thyroid nodules, surgery is recommended for all of them. However, cancer rate at final histology is blood assay.We performed systematic reviews and meta-analyses to compare their features, feasibility, diagnostic performance and cost. GEC, GEC+BRAF, M/F panel+miRNA GEC and M/F panel by NGS were the best in ruling-out malignancy (sensitivity = 90%, 89%, 89% and 90% respectively). BRAF and M/F panel alone and by NGS were the best in ruling-in malignancy (specificity = 100%, 93% and 93%). The M/F by NGS showed the highest accuracy (92%) and BRAF the highest diagnostic odds ratio (DOR) (247). GAL-3-ICC performed well as rule-out (sensitivity = 83%) and rule-in test (specificity = 85%), with good accuracy (84%) and high DOR (27) and is one of the cheapest (113 USD) and easiest one to be performed in different clinical settings.In conclusion, the more accurate molecular-based test-methods are still expensive and restricted to few, highly specialized and centralized laboratories. GAL-3-ICC, although limited by some false negatives, represents the most suitable screening test-method to be applied on a large-scale basis in the diagnostic algorithm of indeterminate thyroid lesions.

  6. How does additional diagnostic testing influence the initial diagnosis in patients with cognitive complaints in a memory clinic setting?

    NARCIS (Netherlands)

    Meijs, A.P.; Claassen, J.A.H.R.; Olde Rikkert, M.G.M.; Schalk, B.W.M; Meulenbroek, O.V.; Kessels, R.P.C.; Melis, R.J.F.

    2015-01-01

    Background: patients suspected of dementia frequently undergo additional diagnostic testing (e.g. brain imaging or neuropsychological assessment) after standard clinical assessment at a memory clinic. This study investigates the use of additional testing in an academic outpatient memory clinic and

  7. How does additional diagnostic testing influence the initial diagnosis in patients with cognitive complaints in a memory clinic setting?

    NARCIS (Netherlands)

    Meijs, A.P.; Claassen, J.A.; Olde Rikkert, M.G.M.; Schalk, B.W.M; Meulenbroek, O.V.; Kessels, R.P.C.; Melis, R.J.F.

    2015-01-01

    BACKGROUND: patients suspected of dementia frequently undergo additional diagnostic testing (e.g. brain imaging or neuropsychological assessment) after standard clinical assessment at a memory clinic. This study investigates the use of additional testing in an academic outpatient memory clinic and

  8. Assessing stakeholder perceptions of the acceptability and feasibility of national scale-up for a dual HIV/syphilis rapid diagnostic test in Malawi.

    Science.gov (United States)

    Maddox, Brandy L Peterson; Wright, Shauntā S; Namadingo, Hazel; Bowen, Virginia B; Chipungu, Geoffrey A; Kamb, Mary L

    2017-12-01

    The WHO recommends pregnant women receive both HIV and syphilis testing at their first antenatal care visit, as untreated maternal infections can lead to severe, adverse pregnancy outcomes. One strategy for increasing testing for both HIV and syphilis is the use of point-of-care (rapid) diagnostic tests that are simple, proven effective and inexpensive. In Malawi, pregnant women routinely receive HIV testing, but only 10% are tested for syphilis at their first antenatal care visit. This evaluation explores stakeholder perceptions of a novel, dual HIV/syphilis rapid diagnostic test and potential barriers to national scale-up of the dual test in Malawi. During June and July 2015, we conducted 15 semistructured interviews with 25 healthcare workers, laboratorians, Ministry of Health leaders and partner agency representatives working in prevention of mother-to-child transmission in Malawi. We asked stakeholders about the importance of a dual rapid diagnostic test, concerns using and procuring the dual test and recommendations for national expansion. Stakeholders viewed the test favourably, citing the importance of a dual rapid test in preventing missed opportunities for syphilis diagnosis and treatment, improving infant outcomes and increasing syphilis testing coverage. Primary technical concerns were about the additional procedural steps needed to perform the test, the possibility that testers may not adhere to required waiting times before interpreting results and difficulty reading and interpreting test results. Stakeholders thought national scale-up would require demonstration of cost-savings, uniform coordination, revisions to testing guidelines and algorithms, training of testers and a reliable supply chain. Stakeholders largely support implementation of a dual HIV/syphilis rapid diagnostic test as a feasible alternative to current antenatal testing. Scale-up will require addressing perceived barriers; negotiating changes to existing algorithms and guidelines

  9. A stochastic model to determine the economic value of changing diagnostic test characteristics for identification of cattle for treatment of bovine respiratory disease.

    Science.gov (United States)

    Theurer, M E; White, B J; Larson, R L; Schroeder, T C

    2015-03-01

    Bovine respiratory disease is an economically important syndrome in the beef industry, and diagnostic accuracy is important for optimal disease management. The objective of this study was to determine whether improving diagnostic sensitivity or specificity was of greater economic value at varied levels of respiratory disease prevalence by using Monte Carlo simulation. Existing literature was used to populate model distributions of published sensitivity, specificity, and performance (ADG, carcass weight, yield grade, quality grade, and mortality risk) differences among calves based on clinical respiratory disease status. Data from multiple cattle feeding operations were used to generate true ranges of respiratory disease prevalence and associated mortality. Input variables were combined into a single model that calculated estimated net returns for animals by diagnostic category (true positive, false positive, false negative, and true negative) based on the prevalence, sensitivity, and specificity for each iteration. Net returns for each diagnostic category were multiplied by the proportion of animals in each diagnostic category to determine group profitability. Apparent prevalence was categorized into low (increasing specificity created more rapid, positive change in net returns than increasing sensitivity. Improvement of diagnostic specificity, perhaps through a confirmatory test interpreted in series or pen-level diagnostics, can increase diagnostic value more than improving sensitivity. Mortality risk was the primary driver for net returns. The results from this study are important for determining future research priorities to analyze diagnostic techniques for bovine respiratory disease and provide a novel way for modeling diagnostic tests.

  10. The evolution of whole field optical diagnostics for external transonic testing

    Science.gov (United States)

    Fry, K. A.; Bryanston-Cross, P.

    1992-09-01

    The diagnostic use of quantitative laser flow visualization techniques has increased rapidly over recent years. The limitations imposed by conventional single point techniques such as laser Doppler anemometry are addressed and how they have been overcome by the development of a new family of whole field measurement techniques is demonstrated. In particular near instantaneous whole field velocity data was obtained in a relatively hostile, industrial 2.74 m x 2.44 m transonic wind tunnel (TWT) at the Aircraft Research Association (ARA). The techniques were evaluated for their suitability for making quantitative measurements in the wing/pylon region of a model wing and engine combination. Three optical diagnostic techniques were successfully developed within the context of the ARA facility. The first technique, laser light sheet (LLS), combines the operation of a pulse laser and video capture system to provide a 'real time' visualization of the flow, whereas a second pulse laser technique, Particle Image Velocimetry (PIV) can be used to make specific quantitative whole field instantaneous velocity measurements. The third method, holography, was used to produce a stored three dimensional visualization of the unsteady and shock wave features of the transonic flow in the gully region. A description is made of their installation and operation, and examples are presented of current test results.

  11. Predictive diagnostic value of the tourniquet test for the diagnosis of dengue infection in adults

    Science.gov (United States)

    Mayxay, Mayfong; Phetsouvanh, Rattanaphone; Moore, Catrin E; Chansamouth, Vilada; Vongsouvath, Manivanh; Sisouphone, Syho; Vongphachanh, Pankham; Thaojaikong, Thaksinaporn; Thongpaseuth, Soulignasack; Phongmany, Simmaly; Keolouangkhot, Valy; Strobel, Michel; Newton, Paul N

    2011-01-01

    Objective To examine the accuracy of the admission tourniquet test in the diagnosis of dengue infection among Lao adults. Methods Prospective assessment of the predictive diagnostic value of the tourniquet test for the diagnosis of dengue infection, as defined by IgM, IgG and NS1 ELISAs (Panbio Ltd, Australia), among Lao adult inpatients with clinically suspected dengue infection. Results Of 234 patients with clinically suspected dengue infection on admission, 73% were serologically confirmed to have dengue, while 64 patients with negative dengue serology were diagnosed as having scrub typhus (39%), murine typhus (11%), undetermined typhus (12%), Japanese encephalitis virus (5%), undetermined flavivirus (5%) and typhoid fever (3%); 25% had no identifiable aetiology. The tourniquet test was positive in 29.1% (95% CI = 23.2–34.9%) of all patients and in 34.1% (95% CI = 27.0–41.2%) of dengue-seropositive patients, in 32.7% (95% CI = 23.5–41.8) of those with dengue fever and in 36.4% (95% CI = 24.7–48.0) of those with dengue haemorrhagic fever. Interobserver agreement for the tourniquet test was 90.2% (95% CI = 86.4–94.0) (Kappa = 0.76). Using ELISAs as the diagnostic gold standard, the sensitivity of the tourniquet test was 33.5–34%; its specificity was 84–91%. The positive and negative predictive values were 85–90% and 32.5–34%, respectively. Conclusions The admission tourniquet test has low sensitivity and adds relatively little value to the diagnosis of dengue among Lao adult inpatients with suspected dengue. Although a positive tourniquet test suggests dengue and that treatment of alternative diagnoses may not be needed, a negative test result does not exclude dengue. PMID:20958892

  12. Kepler Data Validation I: Architecture, Diagnostic Tests, and Data Products for Vetting Transiting Planet Candidates

    Science.gov (United States)

    Twicken, Joseph D.; Catanzarite, Joseph H.; Clarke, Bruce D.; Giroud, Forrest; Jenkins, Jon M.; Klaus, Todd C.; Li, Jie; McCauliff, Sean D.; Seader, Shawn E.; Tennenbaum, Peter; hide

    2018-01-01

    The Kepler Mission was designed to identify and characterize transiting planets in the Kepler Field of View and to determine their occurrence rates. Emphasis was placed on identification of Earth-size planets orbiting in the Habitable Zone of their host stars. Science data were acquired for a period of four years. Long-cadence data with 29.4 min sampling were obtained for approx. 200,000 individual stellar targets in at least one observing quarter in the primary Kepler Mission. Light curves for target stars are extracted in the Kepler Science Data Processing Pipeline, and are searched for transiting planet signatures. A Threshold Crossing Event is generated in the transit search for targets where the transit detection threshold is exceeded and transit consistency checks are satisfied. These targets are subjected to further scrutiny in the Data Validation (DV) component of the Pipeline. Transiting planet candidates are characterized in DV, and light curves are searched for additional planets after transit signatures are modeled and removed. A suite of diagnostic tests is performed on all candidates to aid in discrimination between genuine transiting planets and instrumental or astrophysical false positives. Data products are generated per target and planet candidate to document and display transiting planet model fit and diagnostic test results. These products are exported to the Exoplanet Archive at the NASA Exoplanet Science Institute, and are available to the community. We describe the DV architecture and diagnostic tests, and provide a brief overview of the data products. Transiting planet modeling and the search for multiple planets on individual targets are described in a companion paper. The final revision of the Kepler Pipeline code base is available to the general public through GitHub. The Kepler Pipeline has also been modified to support the Transiting Exoplanet Survey Satellite (TESS) Mission which is expected to commence in 2018.

  13. Kepler Data Validation I—Architecture, Diagnostic Tests, and Data Products for Vetting Transiting Planet Candidates

    Science.gov (United States)

    Twicken, Joseph D.; Catanzarite, Joseph H.; Clarke, Bruce D.; Girouard, Forrest; Jenkins, Jon M.; Klaus, Todd C.; Li, Jie; McCauliff, Sean D.; Seader, Shawn E.; Tenenbaum, Peter; Wohler, Bill; Bryson, Stephen T.; Burke, Christopher J.; Caldwell, Douglas A.; Haas, Michael R.; Henze, Christopher E.; Sanderfer, Dwight T.

    2018-06-01

    The Kepler Mission was designed to identify and characterize transiting planets in the Kepler Field of View and to determine their occurrence rates. Emphasis was placed on identification of Earth-size planets orbiting in the Habitable Zone of their host stars. Science data were acquired for a period of four years. Long-cadence data with 29.4 min sampling were obtained for ∼200,000 individual stellar targets in at least one observing quarter in the primary Kepler Mission. Light curves for target stars are extracted in the Kepler Science Data Processing Pipeline, and are searched for transiting planet signatures. A Threshold Crossing Event is generated in the transit search for targets where the transit detection threshold is exceeded and transit consistency checks are satisfied. These targets are subjected to further scrutiny in the Data Validation (DV) component of the Pipeline. Transiting planet candidates are characterized in DV, and light curves are searched for additional planets after transit signatures are modeled and removed. A suite of diagnostic tests is performed on all candidates to aid in discrimination between genuine transiting planets and instrumental or astrophysical false positives. Data products are generated per target and planet candidate to document and display transiting planet model fit and diagnostic test results. These products are exported to the Exoplanet Archive at the NASA Exoplanet Science Institute, and are available to the community. We describe the DV architecture and diagnostic tests, and provide a brief overview of the data products. Transiting planet modeling and the search for multiple planets on individual targets are described in a companion paper. The final revision of the Kepler Pipeline code base is available to the general public through GitHub. The Kepler Pipeline has also been modified to support the Transiting Exoplanet Survey Satellite (TESS) Mission which is expected to commence in 2018.

  14. TUBERCULIN DIAGNOSTICS: TO BE OR NOT TO BE?

    Directory of Open Access Journals (Sweden)

    N. M. Koretskaya

    2013-01-01

    Full Text Available Tuberculin diagnostics — is a diagnostic method of detection of specific sensitization to Mycobactrerium tuberculosis (MBT. It is used as a specific test during mass population screening on tuberculosis (mass tuberculin diagnostics and for individual examinations (individual tuberculin diagnostics. The aims of the mass diagnostics are: revealing of the patients contaminated with MBT for the first time; revealing of the patients with hyperergic and increasing reactions to tuberculin; selection of the population for vaccination against tuberculosis with weakened BCG vaccine in infants older than 2 months of life who had not been vaccinated after birth, as well for re-vaccination with BCG vaccine; early diagnostics of tuberculosis in children and adolescents; determination of epidemiological characteristics of tuberculosis (population contamination with MBT, yearly risk of contamination with MBT. On mass tuberculin diagnostics it is used only the united intradermal tuberculin Mantoux test with 2 tuberculin units (TU of purified tuberculin in standard solution (prepared form. In the article the author discusses questions of tuberculosis diagnostics in children and adolescents, lists indications to mass tuberculin diagnostics with Mantoux test with 2 TU PPD and test with recombinant tuberculosis allergen. Advantages of both methods, which should be used in order to increase efficacy of tuberculosis diagnostics among children population, are described. It was concluded that switch to the mass screening of tuberculosis with the means of recombinant tuberculosis allergen is not rational under current conditions. The appropriateness of 2-steps examination (necessity of test with recombinant tuberculosis allergen after receiving a positive result of Mantoux test with 2 TU PPD is explained. 

  15. The demand for pregnancy testing: The Aschheim–Zondek reaction, diagnostic versatility, and laboratory services in 1930s Britain

    Science.gov (United States)

    Olszynko-Gryn, Jesse

    2014-01-01

    The Aschheim–Zondek reaction is generally regarded as the first reliable hormone test for pregnancy and as a major product of the ‘heroic age’ of reproductive endocrinology. Invented in Berlin in the late 1920s, by the mid 1930s a diagnostic laboratory in Edinburgh was performing thousands of tests every year for doctors around Britain. In her classic history of antenatal care, sociologist Ann Oakley claimed that the Aschheim–Zondek test launched a ‘modern era’ of obstetric knowledge, which asserted its superiority over that of pregnant women. This article reconsiders Oakley’s claim by examining how pregnancy testing worked in practice. It explains the British adoption of the test in terms less of the medicalisation of pregnancy than of clinicians’ increasing general reliance on laboratory services for differential diagnosis. Crucially, the Aschheim–Zondek reaction was a test not directly for the fetus, but for placental tissue. It was used, less as a yes-or-no test for ordinary pregnancy, than as a versatile diagnostic tool for the early detection of malignant tumours and hormonal deficiencies believed to cause miscarriage. This test was as much a product of oncology and the little-explored world of laboratory services as of reproductive medicine. PMID:24388014

  16. Limited diagnostic accuracy of magnetic resonance imaging and clinical tests for detecting partial-thickness tears of the rotator cuff.

    Science.gov (United States)

    Brockmeyer, Matthias; Schmitt, Cornelia; Haupert, Alexander; Kohn, Dieter; Lorbach, Olaf

    2017-12-01

    The reliable diagnosis of partial-thickness tears of the rotator cuff is still elusive in clinical practise. Therefore, the purpose of the study was to determine the diagnostic accuracy of MR imaging and clinical tests for detecting partial-thickness tears of the rotator cuff as well as the combination of these parameters. 334 consecutive shoulder arthroscopies for rotator cuff pathologies performed during the time period between 2010 and 2012 were analyzed retrospectively for the findings of common clinical signs for rotator cuff lesions and preoperative MR imaging. These were compared with the intraoperative arthroscopic findings as "gold standard". The reports of the MR imaging were evaluated with regard to the integrity of the rotator cuff. The Ellman Classification was used to define partial-thickness tears of the rotator cuff in accordance with the arthroscopic findings. Descriptive statistics, sensitivity, specificity, positive and negative predictive value were calculated. MR imaging showed 80 partial-thickness and 70 full-thickness tears of the rotator cuff. The arthroscopic examination confirmed 64 partial-thickness tears of which 52 needed debridement or refixation of the rotator cuff. Sensitivity for MR imaging to identify partial-thickness tears was 51.6%, specificity 77.2%, positive predictive value 41.3% and negative predictive value 83.7%. For the Jobe-test, sensitivity was 64.1%, specificity 43.2%, positive predictive value 25.9% and negative predictive value 79.5%. Sensitivity for the Impingement-sign was 76.7%, specificity 46.6%, positive predictive value 30.8% and negative predictive value 86.5%. For the combination of MR imaging, Jobe-test and Impingement-sign sensitivity was 46.9%, specificity 85.4%, positive predictive value 50% and negative predictive value 83.8%. The diagnostic accuracy of MR imaging and clinical tests (Jobe-test and Impingement-sign) alone is limited for detecting partial-thickness tears of the rotator cuff. Additionally

  17. Does the Reporting Quality of Diagnostic Test Accuracy Studies, as Defined by STARD 2015, Affect Citation?

    Science.gov (United States)

    Choi, Young Jun; Chung, Mi Sun; Koo, Hyun Jung; Park, Ji Eun; Yoon, Hee Mang; Park, Seong Ho

    2016-01-01

    To determine the rate with which diagnostic test accuracy studies that are published in a general radiology journal adhere to the Standards for Reporting of Diagnostic Accuracy Studies (STARD) 2015, and to explore the relationship between adherence rate and citation rate while avoiding confounding by journal factors. All eligible diagnostic test accuracy studies that were published in the Korean Journal of Radiology in 2011-2015 were identified. Five reviewers assessed each article for yes/no compliance with 27 of the 30 STARD 2015 checklist items (items 28, 29, and 30 were excluded). The total STARD score (number of fulfilled STARD items) was calculated. The score of the 15 STARD items that related directly to the Quality Assessment of Diagnostic Accuracy Studies (QUADAS)-2 was also calculated. The number of times each article was cited (as indicated by the Web of Science) after publication until March 2016 and the article exposure time (time in months between publication and March 2016) were extracted. Sixty-three articles were analyzed. The mean (range) total and QUADAS-2-related STARD scores were 20.0 (14.5-25) and 11.4 (7-15), respectively. The mean citation number was 4 (0-21). Citation number did not associate significantly with either STARD score after accounting for exposure time (total score: correlation coefficient = 0.154, p = 0.232; QUADAS-2-related score: correlation coefficient = 0.143, p = 0.266). The degree of adherence to STARD 2015 was moderate for this journal, indicating that there is room for improvement. When adjusted for exposure time, the degree of adherence did not affect the citation rate.

  18. Dose the reporting quality of diagnostic test accuracy studies, as defined by STARD 2015, affect citation?

    International Nuclear Information System (INIS)

    Choi, Young Jun; Chung, Mi Sun; Koo, Hyun Jung; Park, Ji Eun; Yoon, Hee Mang; Park, Seong Ho

    2016-01-01

    To determine the rate with which diagnostic test accuracy studies that are published in a general radiology journal adhere to the Standards for Reporting of Diagnostic Accuracy Studies (STARD) 2015, and to explore the relationship between adherence rate and citation rate while avoiding confounding by journal factors. All eligible diagnostic test accuracy studies that were published in the Korean Journal of Radiology in 2011–2015 were identified. Five reviewers assessed each article for yes/no compliance with 27 of the 30 STARD 2015 checklist items (items 28, 29, and 30 were excluded). The total STARD score (number of fulfilled STARD items) was calculated. The score of the 15 STARD items that related directly to the Quality Assessment of Diagnostic Accuracy Studies (QUADAS)-2 was also calculated. The number of times each article was cited (as indicated by the Web of Science) after publication until March 2016 and the article exposure time (time in months between publication and March 2016) were extracted. Sixty-three articles were analyzed. The mean (range) total and QUADAS-2-related STARD scores were 20.0 (14.5–25) and 11.4 (7–15), respectively. The mean citation number was 4 (0–21). Citation number did not associate significantly with either STARD score after accounting for exposure time (total score: correlation coefficient = 0.154, p = 0.232; QUADAS-2-related score: correlation coefficient = 0.143, p = 0.266). The degree of adherence to STARD 2015 was moderate for this journal, indicating that there is room for improvement. When adjusted for exposure time, the degree of adherence did not affect the citation rate

  19. Dose the reporting quality of diagnostic test accuracy studies, as defined by STARD 2015, affect citation?

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Young Jun; Chung, Mi Sun; Koo, Hyun Jung; Park, Ji Eun; Yoon, Hee Mang; Park, Seong Ho [Dept. of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center, Seoul (Korea, Republic of)

    2016-09-15

    To determine the rate with which diagnostic test accuracy studies that are published in a general radiology journal adhere to the Standards for Reporting of Diagnostic Accuracy Studies (STARD) 2015, and to explore the relationship between adherence rate and citation rate while avoiding confounding by journal factors. All eligible diagnostic test accuracy studies that were published in the Korean Journal of Radiology in 2011–2015 were identified. Five reviewers assessed each article for yes/no compliance with 27 of the 30 STARD 2015 checklist items (items 28, 29, and 30 were excluded). The total STARD score (number of fulfilled STARD items) was calculated. The score of the 15 STARD items that related directly to the Quality Assessment of Diagnostic Accuracy Studies (QUADAS)-2 was also calculated. The number of times each article was cited (as indicated by the Web of Science) after publication until March 2016 and the article exposure time (time in months between publication and March 2016) were extracted. Sixty-three articles were analyzed. The mean (range) total and QUADAS-2-related STARD scores were 20.0 (14.5–25) and 11.4 (7–15), respectively. The mean citation number was 4 (0–21). Citation number did not associate significantly with either STARD score after accounting for exposure time (total score: correlation coefficient = 0.154, p = 0.232; QUADAS-2-related score: correlation coefficient = 0.143, p = 0.266). The degree of adherence to STARD 2015 was moderate for this journal, indicating that there is room for improvement. When adjusted for exposure time, the degree of adherence did not affect the citation rate.

  20. The Accuracy of Diagnostic Tests for Lyme Disease in Humans, A Systematic Review and Meta-Analysis of North American Research.

    Directory of Open Access Journals (Sweden)

    Lisa A Waddell

    Full Text Available There has been an increasing incidence of Lyme disease (LD in Canada and the United States corresponding to the expanding range of the Ixodes tick vector and Lyme disease agent (Borrelia burgdorferi sensu stricto. There are many diagnostic tests for LD available in North America, all of which have some performance issues, and physicians are concerned about the appropriate use and interpretation of these tests. The objective of this systematic review is to summarize the North American evidence on the accuracy of diagnostic tests and test regimes at various stages of LD. Included in the review are 48 studies on diagnostic tests used in North America published since 1995. Thirteen studies examined a two-tier serological test protocol vs. clinical diagnosis, 24 studies examined single assays vs. clinical diagnosis, 9 studies examined single immunoblot vs. clinical diagnosis, 7 studies compared culture or PCR direct detection methods vs. clinical diagnosis, 22 studies compared two or more tests with each other and 8 studies compared a two-tiered serological test protocol to another test. Recent studies examining the sensitivity and specificity of various test protocols noted that the Immunetics® C6 B. burgdorferi ELISA™ and the two tier approach have superior specificity compared to proposed replacements, and the CDC recommended western blot algorithm has equivalent or superior specificity over other proposed test algorithms. There is a dramatic increase in test sensitivity with progression of B. burgdorferi infection from early to late LD. Direct detection methods, culture and PCR of tissue or blood samples were not as sensitive or timely compared to serological testing. It was also noted that there are a large number of both commercial (n = 42 and in-house developed tests used by private laboratories which have not been evaluated in the primary literature.

  1. The Accuracy of Diagnostic Tests for Lyme Disease in Humans, A Systematic Review and Meta-Analysis of North American Research

    Science.gov (United States)

    Lindsay, Robbin; Ogden, Nicholas

    2016-01-01

    There has been an increasing incidence of Lyme disease (LD) in Canada and the United States corresponding to the expanding range of the Ixodes tick vector and Lyme disease agent (Borrelia burgdorferi sensu stricto). There are many diagnostic tests for LD available in North America, all of which have some performance issues, and physicians are concerned about the appropriate use and interpretation of these tests. The objective of this systematic review is to summarize the North American evidence on the accuracy of diagnostic tests and test regimes at various stages of LD. Included in the review are 48 studies on diagnostic tests used in North America published since 1995. Thirteen studies examined a two-tier serological test protocol vs. clinical diagnosis, 24 studies examined single assays vs. clinical diagnosis, 9 studies examined single immunoblot vs. clinical diagnosis, 7 studies compared culture or PCR direct detection methods vs. clinical diagnosis, 22 studies compared two or more tests with each other and 8 studies compared a two-tiered serological test protocol to another test. Recent studies examining the sensitivity and specificity of various test protocols noted that the Immunetics® C6 B. burgdorferi ELISA™ and the two tier approach have superior specificity compared to proposed replacements, and the CDC recommended western blot algorithm has equivalent or superior specificity over other proposed test algorithms. There is a dramatic increase in test sensitivity with progression of B. burgdorferi infection from early to late LD. Direct detection methods, culture and PCR of tissue or blood samples were not as sensitive or timely compared to serological testing. It was also noted that there are a large number of both commercial (n = 42) and in-house developed tests used by private laboratories which have not been evaluated in the primary literature. PMID:28002488

  2. Empirical likelihood-based confidence intervals for the sensitivity of a continuous-scale diagnostic test at a fixed level of specificity.

    Science.gov (United States)

    Gengsheng Qin; Davis, Angela E; Jing, Bing-Yi

    2011-06-01

    For a continuous-scale diagnostic test, it is often of interest to find the range of the sensitivity of the test at the cut-off that yields a desired specificity. In this article, we first define a profile empirical likelihood ratio for the sensitivity of a continuous-scale diagnostic test and show that its limiting distribution is a scaled chi-square distribution. We then propose two new empirical likelihood-based confidence intervals for the sensitivity of the test at a fixed level of specificity by using the scaled chi-square distribution. Simulation studies are conducted to compare the finite sample performance of the newly proposed intervals with the existing intervals for the sensitivity in terms of coverage probability. A real example is used to illustrate the application of the recommended methods.

  3. Diagnostic laboratory tests for systemic autoimmune rheumatic diseases: unmet needs towards harmonization.

    Science.gov (United States)

    Meroni, Pier Luigi; Borghi, Maria Orietta

    2018-05-01

    Autoantibodies are helpful tools not only for the diagnosis and the classification of systemic autoimmune rheumatic diseases (SARD) but also for sub-grouping patients and/or for monitoring disease activity or specific tissue/organ damage. Consequently, the role of the diagnostic laboratory in the management of SARD is becoming more and more important. The advent of new techniques raised the need of updating and harmonizing our use/interpretation of the assays. We discuss in this opinion paper some of these issues. Indirect immunofluorescence (IIF) was originally suggested as the reference technique for anti-nuclear antibody (ANA) detection as previous solid phase assays (SPA) displayed lower sensitivity. The new available SPA are now offering better results and can represent alternative or even complementary diagnostic tools for ANA detection. The improved sensitivity of SPA technology is also changing our interpretation of the results for other types of autoantibody assays, but we need updating their calibration and new reference materials are going to be obtained in order to harmonize the assays. There is growing evidence that the identification of autoantibody combinations or profiles is helpful in improving diagnosis, patients' subgrouping and predictivity for disease evolution in the field of SARD. We report some explanatory examples to support the idea to make the use of these autoantibody profiles more and more popular. The technological evolution of the autoimmune assays is going to change our routine diagnostic laboratory tests for SARD and validation of new algorithms is needed in order to harmonize our approach to the issue.

  4. Monocyte Activation in Immunopathology: Cellular Test for Development of Diagnostics and Therapy

    Directory of Open Access Journals (Sweden)

    Ekaterina A. Ivanova

    2016-01-01

    Full Text Available Several highly prevalent human diseases are associated with immunopathology. Alterations in the immune system are found in such life-threatening disorders as cancer and atherosclerosis. Monocyte activation followed by macrophage polarization is an important step in normal immune response to pathogens and other relevant stimuli. Depending on the nature of the activation signal, macrophages can acquire pro- or anti-inflammatory phenotypes that are characterized by the expression of distinct patterns of secreted cytokines and surface antigens. This process is disturbed in immunopathologies resulting in abnormal monocyte activation and/or bias of macrophage polarization towards one or the other phenotype. Such alterations could be used as important diagnostic markers and also as possible targets for the development of immunomodulating therapy. Recently developed cellular tests are designed to analyze the phenotype and activity of living cells circulating in patient’s bloodstream. Monocyte/macrophage activation test is a successful example of cellular test relevant for atherosclerosis and oncopathology. This test demonstrated changes in macrophage activation in subclinical atherosclerosis and breast cancer and could also be used for screening a panel of natural agents with immunomodulatory activity. Further development of cellular tests will allow broadening the scope of their clinical implication. Such tests may become useful tools for drug research and therapy optimization.

  5. New Exercise-Dipyridamole Combined Test for Nuclear Cardiology in Insufficient Effort: Appropriate Diagnostic Sensitivity Keeping Exercise Prognosis

    Directory of Open Access Journals (Sweden)

    Inés Vidal Cortinas

    2015-08-01

    Full Text Available AbstractBackground:Myocardial perfusion scintigraphy (MPS in patients not reaching 85% of the maximum predicted heart rate (MPHR has reduced sensitivity.Objectives:In an attempt to maintain diagnostic sensitivity without losing functional exercise data, a new exercise and dipyridamole combined protocol (EDCP was developed. Our aim was to evaluate the feasibility and safety of this protocol and to compare its diagnostic sensitivity against standard exercise and dipyridamole protocols.Methods:In patients not reaching a sufficient exercise (SE test and with no contraindications, 0.56 mg/kg of dipyridamole were IV administered over 1 minute simultaneously with exercise, followed by 99mTc-MIBI injection.Results:Of 155 patients, 41 had MPS with EDCP, 47 had a SE test (≥ 85% MPHR and 67 underwent the dipyridamole alone test (DIP. They all underwent coronary angiography within 3 months. The three stress methods for diagnosis of coronary lesions had their sensitivity compared. For stenosis ≥ 70%, EDCP yielded 97% sensitivity, SE 90% and DIP 95% (p = 0.43. For lesions ≥ 50%, the sensitivities were 94%, 88% and 95%, respectively (p = 0.35. Side effects of EDCP were present in only 12% of the patients, significantly less than with DIP (p < 0.001.Conclusions:The proposed combined protocol is a valid and safe method that yields adequate diagnostic sensitivity, keeping exercise prognostic information in patients unable to reach target heart rate, with fewer side effects than the DIP.

  6. Estimation of Sensitivity and Specificity of Three Conditionally Dependent Diagnostic Tests in the Absence of a Gold Standard

    NARCIS (Netherlands)

    Engel, B.; Swildens, B.; Stegeman, J.A.; Buist, W.G.; Jong, de M.

    2006-01-01

    This article presents a model to evaluate the accuracy of diagnostic tests. Data from three tests for the detection of EF-positive Streptococcus suis serotype 2 strains in sows were analyzed. The data were collected in a field study in the absence of a gold standard, that is, the true disease status

  7. Gaseous electron multiplier-based soft x-ray plasma diagnostics development: Preliminary tests at ASDEX Upgrade

    Energy Technology Data Exchange (ETDEWEB)

    Chernyshova, M., E-mail: maryna.chernyshova@ipplm.pl; Malinowski, K.; Czarski, T.; Kowalska-Strzęciwilk, E. [Institute of Plasma Physics and Laser Microfusion, Hery 23, 01-497 Warsaw (Poland); Wojeński, A.; Poźniak, K. T.; Kasprowicz, G.; Krawczyk, R.; Kolasiński, P.; Zabołotny, W.; Zienkiewicz, P. [Institute of Electronic Systems, Warsaw University of Technology, Nowowiejska 15/19, 00-665 Warsaw (Poland); Vezinet, D.; Herrmann, A. [Max Planck Institute for Plasma Physics, Boltzmannstr. 2, 85748 Garching (Germany); Mazon, D.; Jardin, A. [CEA, IRFM, F-13108 Saint-Paul-lez-Durance (France)

    2016-11-15

    A Gaseous Electron Multiplier (GEM)-based detector is being developed for soft X-ray diagnostics on tokamaks. Its main goal is to facilitate transport studies of impurities like tungsten. Such studies are very relevant to ITER, where the excessive accumulation of impurities in the plasma core should be avoided. This contribution provides details of the preliminary tests at ASDEX Upgrade (AUG) with a focus on the most important aspects for detector operation in harsh radiation environment. It was shown that both spatially and spectrally resolved data could be collected, in a reasonable agreement with other AUG diagnostics. Contributions to the GEM signal include also hard X-rays, gammas, and neutrons. First simulations of the effect of high-energy photons have helped understanding these contributions.

  8. Diagnostic test for prenatal identification of Down's syndrome and mental retardation and gene therapy therefor

    Science.gov (United States)

    Smith, Desmond J.; Rubin, Edward M.

    2000-01-01

    A a diagnostic test useful for prenatal identification of Down syndrome and mental retardation. A method for gene therapy for correction and treatment of Down syndrome. DYRK gene involved in the ability to learn. A method for diagnosing Down's syndrome and mental retardation and an assay therefor. A pharmaceutical composition for treatment of Down's syndrome mental retardation.

  9. ISHM-oriented adaptive fault diagnostics for avionics based on a distributed intelligent agent system

    Science.gov (United States)

    Xu, Jiuping; Zhong, Zhengqiang; Xu, Lei

    2015-10-01

    In this paper, an integrated system health management-oriented adaptive fault diagnostics and model for avionics is proposed. With avionics becoming increasingly complicated, precise and comprehensive avionics fault diagnostics has become an extremely complicated task. For the proposed fault diagnostic system, specific approaches, such as the artificial immune system, the intelligent agents system and the Dempster-Shafer evidence theory, are used to conduct deep fault avionics diagnostics. Through this proposed fault diagnostic system, efficient and accurate diagnostics can be achieved. A numerical example is conducted to apply the proposed hybrid diagnostics to a set of radar transmitters on an avionics system and to illustrate that the proposed system and model have the ability to achieve efficient and accurate fault diagnostics. By analyzing the diagnostic system's feasibility and pragmatics, the advantages of this system are demonstrated.

  10. Diagnostic tests in Raynaud's phenomena in workers exposed to vibration: a comparative study

    DEFF Research Database (Denmark)

    Olsen, N

    1988-01-01

    Four objective tests to evaluate Raynaud's phenomena (RP) in workers exposed to handarm vibrations were applied on 23 exposed men with RP (vibration induced white finger 18, primary Raynaud's phenomenon 5), 56 exposed men without RP, and 15 male controls. Finger systolic blood pressure was measured...... greater than 0.20). The results indicate that a finger colour test may be as valuable as a FSP(0) test for diagnostic purposes. FSP(A) only indicates if a cold response is exaggerated and does not diagnose RP. The pressure measurements may further be of guidance in evaluating preventive measures...... by a cuff and strain gauge technique after combined body cooling and finger cooling during five minute ischaemia to 30 degrees, 15 degrees, and 6 degrees C. An attack of RP was detected as a zero pressure, FSP(0) test, whereas a pressure, reduced to a value below the normal 95% confidence limit at 6 degrees...

  11. Ophthalmic diagnostic tests, orbital anatomy, and adnexal histology of the broad-snouted caiman (Caiman latirostris).

    Science.gov (United States)

    Oriá, Arianne P; Oliveira, Alberto Vinícius D; Pinna, Melissa H; Martins Filho, Emanoel F; Estrela-Lima, Alessandra; Peixoto, Tiago C; Silva, Renata Maria M da; Santana, Fernanda O; Meneses, Íris Daniela S; Requião, Kátia G; Ofri, Ron

    2015-01-01

    The aim of this study was to establish normal ophthalmic parameters for selected diagnostic tests, and to describe the orbital anatomy and adnexal histology of the broad-snouted caiman. A total of 35 Caiman latirostris that were free of obvious ocular diseases were used to measure the parameters in this investigation. Ages ranged from 5 to 15 years. Ophthalmic diagnostic tests were conducted, including evaluation of tear production with Schirmer Tear test-1 (STT1), culture of the conjunctival bacterial flora, applanation tonometry, conjunctival cytology, nictiating membrane incursion frequency test (NMIFT), endodontic absorbent paper point tear test (EAPPTT), palpebral fissure length measurement (PFL) and B-mode ultrasonography. Adnexal histology and skull samples were studied. Mean (±SD) STT1 was 3.4 ± 3.6 mm/min (95% confidence interval of 2.01-4.78 mm/min), intraocular pressure (IOP) was 12.9 ± 6.2 mmHg, NMIFT was 6.0 ± 3.5, EAPPTT was 17.1 ± 2.5 mm/min, PFL was 28.9 ± 3.0 mm, anterior chamber depth was 3.1 ± 0.3 mm, lens axial length was 8.4 ± 0.6 mm, vitreous chamber depth was 7.9 ± 0.7 mm and axial globe length was 19.9 ± 1.3 mm. For all animals evaluated, Bacillus sp., Diphteroids and Staphylococcus sp. were predominant. © 2013 American College of Veterinary Ophthalmologists.

  12. Optical diagnostics in the advanced test accelerator (ATA) environment

    International Nuclear Information System (INIS)

    Chong, Y.P.; Cornish, J.P.; Donnelly, D.

    1987-05-01

    The ATA is a 50-MeV, 10-kA, 70-ns pulsed electron beam accelerator that generates an extremely harsh environment for diagnostic measurements. Diagnostic targets placed in the beamline are subject to damage, frequently being destroyed by a single pulse. High radiation (x-ray, gamma, and neutron) and electromagnetic interference levels preclude placing components near the beamline that are susceptible to radiation damage. Examples of such components are integrated circuit elements, hydrocarbons such as Teflon insulation, and optical components that darken, resulting in transmission loss. Optical diagnostics play an important part in measuring experimental parameters such as the beam current density profile. A large number of optical lines of sight (LOS) are routinely deployed along the experimental beamlines that use the ATA beam. Gated TV cameras are located outside the accelerator tunnel, because the tunnel is inaccessible during operations. We will describe and discuss the difficulties, problems, and solutions encountered in making optical measurements in the ATA environment

  13. A centrifugal microfluidic platform for point-of-care diagnostic applications

    Directory of Open Access Journals (Sweden)

    Suzanne Hugo

    2014-02-01

    Full Text Available Microfluidic systems enable precise control over tiny volumes of fluid in a compact and low-cost form, thus providing the ideal platform on which to develop point-of-care diagnostic solutions. Centrifugal microfluidic systems, also referred to as lab-on-a-disc or lab-on-a-CD systems, provide a particularly attractive solution for the implementation of microfluidic point-of-care diagnostic solutions as a result of their simple and compact instrumentation, as well as their functional diversity. Here we detail the implementation of a centrifugal microfluidic platform the first of its kind in South Africa as a foundation for the development of point-of-care diagnostic applications for which both the need and impact is great. The centrifugal microfluidic platform consists of three main components: a microfluidic disc device similar in size and shape to a CD, a system for controlling fluid flow on the device, and a system for recording the results obtained. These components have been successfully implemented and tested. Preliminary test results show that microfluidic functions such as pumping and valving of fluids can be successfully achieved, as well as the generation of monodisperse microfluidic droplets, providing a complete centrifugal microfluidic platform and the building blocks on which to develop a variety of applications, including point-of-care diagnostics. The lab-on-a-disc platform has the potential to provide new diagnostic solutions at the point-of-need in health- and industry-related areas. This paves the way for providing resource limited areas with services such as improved, decentralised health-care access or water-quality monitoring, and reduced diagnosis times at a low cost.

  14. Dual-focus Magnification, High-Definition Endoscopy Improves Pathology Detection in Direct-to-Test Diagnostic Upper Gastrointestinal Endoscopy.

    Science.gov (United States)

    Bond, Ashley; Burkitt, Michael D; Cox, Trevor; Smart, Howard L; Probert, Chris; Haslam, Neil; Sarkar, Sanchoy

    2017-03-01

    In the UK, the majority of diagnostic upper gastrointestinal (UGI) endoscopies are a result of direct-to-test referral from the primary care physician. The diagnostic yield of these tests is relatively low, and the burden high on endoscopy services. Dual-focus magnification, high-definition endoscopy is expected to improve detection and classification of UGI mucosal lesions and also help minimize biopsies by allowing better targeting. This is a retrospective study of patients attending for direct-to-test UGI endoscopy from January 2015 to June 2015. The primary outcome of interest was the identification of significant pathology. Detection of significant pathology was modelled using logistic regression. 500 procedures were included. The mean age of patients was 61.5 (±15.6) years; 60.8% of patients were female. Ninety-four gastroscopies were performed using dual-focus magnification high-definition endoscopy. Increasing age, male gender, type of endoscope, and type of operator were all identified as significant factors influencing the odds of detecting significant mucosal pathology. Use of dual-focus magnification, high-definition endoscopy was associated with an odds ratio of 1.87 (95%CI 1.11-3.12) favouring the detection of significant pathology. Subsequent analysis suggested that the increased detection of pathology during dual-focus magnification, high-definition endoscopy also influenced patient follow-up and led to a 3.0 fold (p=0.04) increase in the proportion of patients entered into an UGI endoscopic surveillance program. Dual-focus magnification, high-definition endoscopy improved the diagnostic yield for significant mucosal pathology in patients referred for direct-to-test endoscopy. If this finding is recapitulated elsewhere it will have substantial impact on the provision of UGI endoscopic services.

  15. Teaching-Learning Conceptions and Academic Achievement: The Mediating Role of Test Anxiety

    Science.gov (United States)

    Bas, Gökhan

    2016-01-01

    The current research aimed at examining the mediating role of test anxiety in the relationship between teaching-learning conceptions and academic achievement. The correlation investigation model was adopted in this research. The participants of the research were volunteering teachers (n = 108) and students (n = 526) from five different high…

  16. Proband-only medical exome sequencing as a cost-effective first-tier genetic diagnostic test for patients without prior molecular tests and clinical diagnosis in a developing country: the China experience.

    Science.gov (United States)

    Hu, Xuyun; Li, Niu; Xu, Yufei; Li, Guoqiang; Yu, Tingting; Yao, Ru-En; Fu, Lijun; Wang, Jiwen; Yin, Lei; Yin, Yong; Wang, Ying; Jin, Xingming; Wang, Xiumin; Wang, Jian; Shen, Yiping

    2017-11-02

    PurposeTo evaluate the performance of proband-only medical exome sequencing (POMES) as a cost-effective first-tier diagnostic test for pediatric patients with unselected conditions.MethodsA total of 1,323 patients were tested by POMES, which targeted 2,742 known disease-causing genes. Clinical relevant variants were Sanger-confirmed in probands and parents. We assessed the diagnostic validity and clinical utility of POMES by means of a survey questionnaire.ResultsPOMES, ordered by 136 physicians, identified 512 pathogenic or likely pathogenic variants associated with over 200 conditions. The overall diagnostic rate was 28.8%, ranging from 10% in neonatal intensive care unit patients to over 35% in pediatric intensive care unit patients. The test results had an impact on the management of the 45.1% of patients for whom there were positive findings. The average turnaround time was 57 days; the cost was $360/case.ConclusionWe adopted a relatively efficient and cost-effective approach in China for the molecular diagnosis of pediatric patients with suspected genetic conditions. While training for clinical geneticists and other specialists is lagging behind in China POMES is serving as a diagnostic equalizer for patients who do not normally receive extensive clinical evaluation and clinical diagnosis prior to testing. This Chinese experience should be applicable to other developing countries that are lacking clinical, financial, and personnel resources.GENETICS in MEDICINE advance online publication, 2 November 2017; doi:10.1038/gim.2017.195.

  17. Fast, fat-suppressed diagnostic imaging of the breast

    International Nuclear Information System (INIS)

    Metzger, G.J.; Weatherall, P.

    1999-01-01

    Maximum sensitivity and diagnostic precision of MR imaging of the breast can be achieved only with fat-suppressed diagnostic scans with high resolution. Optimal results were obtained with a 3D-FFE sequence and excitation by a binomial pulse and an amplitude-modulated binomial pulse. (orig./CB) [de

  18. Recommendations for reporting of systematic reviews and meta-analyses of diagnostic test accuracy: a systematic review

    NARCIS (Netherlands)

    McGrath, Trevor A.; Alabousi, Mostafa; Skidmore, Becky; Korevaar, Daniël A.; Bossuyt, Patrick M. M.; Moher, David; Thombs, Brett; McInnes, Matthew D. F.

    2017-01-01

    This study is to perform a systematic review of existing guidance on quality of reporting and methodology for systematic reviews of diagnostic test accuracy (DTA) in order to compile a list of potential items that might be included in a reporting guideline for such reviews: Preferred Reporting Items

  19. The Development and Validation of a Three-Tier Diagnostic Test Measuring Pre-Service Elementary Education and Secondary Science Teachers' Understanding of the Water Cycle

    Science.gov (United States)

    Schaffer, Dannah Lynn

    2013-01-01

    The main goal of this research study was to develop and validate a three-tier diagnostic test to determine pre-service teachers' (PSTs) conceptual knowledge of the water cycle. For a three-tier diagnostic test, the first tier assesses content knowledge; in the second tier, a reason is selected for the content answer; and the third tier allows…

  20. Diagnostic value of ACTH stimulation test in determining the subtypes of primary aldosteronism.

    Science.gov (United States)

    Jiang, Yiran; Zhang, Cui; Wang, Weiqing; Su, Tingwei; Zhou, Weiwei; Jiang, Lei; Zhu, Wei; Xie, Jing; Ning, Guang

    2015-05-01

    Adrenal venous sampling is recommended as the golden standard for subtyping primary aldosteronism (PA). However, it is invasive and inconvenient, and seeking a better way to make differential diagnosis of PA is necessary. The objective of the study was to evaluate the diagnostic value of ACTH stimulation test under 1 mg dexamethasone suppression test (DST) in determining the subtypes of PA. Ninety-five patients with PA confirmed by saline infusion test were included in this study. According to adrenal venous sampling and histopathology, 39 patients were diagnosed as bilateral adrenal hyperplasia (BAH), 37 as aldosterone-producing adenoma (APA), and 19 as unilateral adrenal hyperplasia (UAH). An ACTH stimulation test under 1 mg DST was performed in all patients. Plasma aldosterone and cortisol levels were measured every 30 minutes until 120 minutes after the iv injection of 50 IU ACTH. During the ACTH stimulation test, aldosterone levels in APA and UAH were similar (P > .05) but higher than those in BAH (P APA and UAH) were significantly higher than bilateral PA (BAH) (P guide further treatment in PA patients.