WorldWideScience

Sample records for diagnostic techniques ophthalmological

  1. Therapeutic application of lasers in ophthalmology

    International Nuclear Information System (INIS)

    Misiuk-Hojlo, M.; Krzyzanowska-Berkowska, P.; Hill-Bator, A.

    2007-01-01

    Lasers have found application in diverse branches of medicine. In ophthalmology, laser technology has various therapeutic and diagnostic applications. The purpose of this article is to review the major therapeutic applications of lasers in different eye disorders. The effects of lasers on biological tissues and different laser techniques as well as the indications for laser therapy in various parts of the eye are discussed. Lasers are used to treat glaucoma and many vascular disorders of the retina. Laser treatment may be useful in preventing the development of neovascularization in diabetic retinopathy, BRVO, or CRVO. Laser techniques are also available for the treatment of the exudative form of age-related macular degeneration (AMD) and some malignant and benign intraocular tumors and in retina abnormalities which predispose to rhegmatogenous retinal detachment. Corneal laser surgery is the most frequently applied laser procedure in ophthalmology. PRK, LASIK, and LASEK are used to correct errors in vision such as myopia, hyperopia, and astigmatism. Laser photocoagulation is also helpful in cataract surgery. Nowadays, lasers have become so universal that it is difficult to imagine ophthalmology without them. We are still witnessing rapid advances in the development of laser techniques, especially in plastic surgery, cataract extraction, and ocular imaging. (authors)

  2. The use of ultrasonography in pediatric ophthalmology - diagnostics of ophthalmic disorders in newborns and infants

    International Nuclear Information System (INIS)

    Modrzejewska, M.; Karczewicz, D.; Wilk, G.

    2006-01-01

    Ultrasonographic (US) examinations in ophthalmology play a major role as one of the additional examination modes in the diagnostics of orbital diseases, and in cases of changes of a vascular origin it is useful in the evaluation of blood flow velocity. The special value of this examination in the assessment of the opaque optical structures on the fundus of the eye is emphasized. The aim of the study was 1) to present the ultrasonographic images and the efficacy of the method in the evaluation of some congenital and acquired bulbar diseases and 2) on the bases of the advantages of the examination, to determine whether ultrasonography could be included as a screening method in the diagnostics of preterm infants as well as a method of choice in term infants with ophthalmologic diseases. One thousand sixty-two children between the ages of 3 weeks to 12 months, of whom 1135 were preterm and 27 term infants, with ophthalmologic changes were examined. A real-time ultrasonographic apparatus with color Doppler (5-7.5 MHz sectoral and 7.5-10 MHz linear transducers). The US examinations of preterm infants were conducted four times and in term infants twice. In 105 children (8.99%) and in 184 eyes, premature retinopathy, intra-bulbar tumors, retinal ablation, posttraumatic changes, inflammatory processes in the posterior chamber of the eyeball, and congenital anomalies of the bulbar structures were diagnosed. Bulbar ultrasonography, being a safe, quick, and efficient examination, should be included as an additional screening method in preterm infants. Ultrasonography with color Doppler is an efficient method of choice for diagnosing problematic diseases of the eyeballs of infants. (author)

  3. Feedback of final year ophthalmology postgraduates about their residency ophthalmology training in South India

    Directory of Open Access Journals (Sweden)

    K Ajay

    2014-01-01

    Full Text Available Background and Aims: This study documents a survey of final-year ophthalmology postgraduate students on the subject of their residency training. A similar survey conducted 7 years ago published in IJO had concluded that the residency program was not up to expectations in many centers. Our study aimed to see if ophthalmology training and student perceptions differed since then. Materials and Methods: For our study, we added a few questions to the same questionnaire used in the article "which is the best method to learn ophthalmology? Resident doctors′ perspective of ophthalmology training" published in IJO, Vol. 56 (5. Results: Forty-nine students (62.02% returned completed forms. Most students desired an orientation program on entering residency, and wished to undergo diagnostic training initially. Case-presentation with demonstration and Wet-lab learning were most preferred. There was a big difference between the number of surgeries students actually performed and the number they felt would have been ideal. Conclusion: On the whole, the students still felt the need for improved training across all aspects of ophthalmology.

  4. Therapeutic application of lasers in ophthalmology; Terapeutyczne zastosowanie laserow w okulistyce

    Energy Technology Data Exchange (ETDEWEB)

    Misiuk-Hojlo, M; Krzyzanowska-Berkowska, P; Hill-Bator, A [Department of Ophthalmology, Silesian Piasts University of Medicine in Wroclaw (Poland)

    2007-07-01

    Lasers have found application in diverse branches of medicine. In ophthalmology, laser technology has various therapeutic and diagnostic applications. The purpose of this article is to review the major therapeutic applications of lasers in different eye disorders. The effects of lasers on biological tissues and different laser techniques as well as the indications for laser therapy in various parts of the eye are discussed. Lasers are used to treat glaucoma and many vascular disorders of the retina. Laser treatment may be useful in preventing the development of neovascularization in diabetic retinopathy, BRVO, or CRVO. Laser techniques are also available for the treatment of the exudative form of age-related macular degeneration (AMD) and some malignant and benign intraocular tumors and in retina abnormalities which predispose to rhegmatogenous retinal detachment. Corneal laser surgery is the most frequently applied laser procedure in ophthalmology. PRK, LASIK, and LASEK are used to correct errors in vision such as myopia, hyperopia, and astigmatism. Laser photocoagulation is also helpful in cataract surgery. Nowadays, lasers have become so universal that it is difficult to imagine ophthalmology without them. We are still witnessing rapid advances in the development of laser techniques, especially in plastic surgery, cataract extraction, and ocular imaging. (authors)

  5. Neuro-ophthalmology update.

    Science.gov (United States)

    Weber, Konrad P; Straumann, Dominik

    2014-07-01

    This review summarizes the most relevant articles from the field of neuro-ophthalmology published in the Journal of Neurology from January 2012 to July 2013. With the advent of video-oculography, several articles describe new applications for eye movement recordings as a diagnostic tool for a wide range of disorders. In myasthenia gravis, anti-Kv1.4 and anti-Lrp4 have been characterized as promising novel autoantibodies for the diagnosis of hitherto 'seronegative' myasthenia gravis. Several articles address new diagnostic and therapeutic approaches to neuromyelitis optica, which further sharpen its profile as a distinct entity. Additionally, 4-aminopyridine has become a standard therapeutic for patients with cerebellar downbeat nystagmus. Finally, revised diagnostic criteria have been proposed for chronic relapsing inflammatory optic neuropathy based on a careful literature review over the last decade.

  6. Focused ultrasound in ophthalmology

    Directory of Open Access Journals (Sweden)

    Silverman RH

    2016-09-01

    Full Text Available Ronald H Silverman1,2 1Department of Ophthalmology, Columbia University Medical Center, 2F.L. Lizzi Center for Biomedical Engineering, Riverside Research, New York, NY, USA Abstract: The use of focused ultrasound to obtain diagnostically significant information about the eye goes back to the 1950s. This review describes the historical and technological development of ophthalmic ultrasound and its clinical application and impact. Ultrasound, like light, can be focused, which is crucial for formation of high-resolution, diagnostically useful images. Focused, single-element, mechanically scanned transducers are most common in ophthalmology. Specially designed transducers have been used to generate focused, high-intensity ultrasound that through thermal effects has been used to treat glaucoma (via cilio-destruction, tumors, and other pathologies. Linear and annular transducer arrays offer synthetic focusing in which precise timing of the excitation of independently addressable array elements allows formation of a converging wavefront to create a focus at one or more programmable depths. Most recently, linear array-based plane-wave ultrasound, in which the array emits an unfocused wavefront and focusing is performed solely on received data, has been demonstrated for imaging ocular anatomy and blood flow. While the history of ophthalmic ultrasound extends back over half-a-century, new and powerful technologic advances continue to be made, offering the prospect of novel diagnostic capabilities. Keywords: ophthalmic ultrasound, ultrasound biomicroscopy (UBM, high-intensity focused ultrasound (HIFU, ultrafast imaging, Doppler imaging 

  7. [Basic research in ophthalmology in Germany and its international context].

    Science.gov (United States)

    Schlötzer-Schrehardt, U; Cursiefen, C

    2017-09-01

    Experimental basic research provides the foundations for the elucidation of pathophysiological mechanisms of diseases and the development of novel diagnostic and therapeutic strategies for ophthalmological diseases. The objective of this contribution is to provide an overview of the international interconnection of basic research in ophthalmology in Germany. The international context of ophthalmological research conducted in Germany is presented by means of personal experiences and data published by the German Ophthalmological Society (DOG), the German Research Foundation (DFG) and the European Union (EU). Due to the lack of organized databases this article lays no claim to completeness. Basic research in ophthalmology in Germany is mainly conducted in university eye departments and is mainly related to the etiology, pathophysiology and therapy development for various ophthalmic diseases. It is primarily funded by the DFG, the Federal Ministry of Education and Research (BMBF) and the EU plays an increasingly important role. Thus, ophthalmological research is integrated into numerous European research networks and beyond that into many international interconnections and relationships. In Germany, both clinical and basic research in ophthalmology is integrated into many international networks and is only functionally viable in an international context; however, given the increasing impact of ophthalmological research in Asian countries, future strategies require a continued focus on career development, research infrastructure, working environment and international cooperation.

  8. Reported estimates of diagnostic accuracy in ophthalmology conference abstracts were not associated with full-text publication.

    Science.gov (United States)

    Korevaar, Daniël A; Cohen, Jérémie F; Spijker, René; Saldanha, Ian J; Dickersin, Kay; Virgili, Gianni; Hooft, Lotty; Bossuyt, Patrick M M

    2016-11-01

    To assess whether conference abstracts that report higher estimates of diagnostic accuracy are more likely to reach full-text publication in a peer-reviewed journal. We identified abstracts describing diagnostic accuracy studies, presented between 2007 and 2010 at the Association for Research in Vision and Ophthalmology (ARVO) Annual Meeting. We extracted reported estimates of sensitivity, specificity, area under the receiver operating characteristic curve (AUC), and diagnostic odds ratio (DOR). Between May and July 2015, we searched MEDLINE and EMBASE to identify corresponding full-text publications; if needed, we contacted abstract authors. Cox regression was performed to estimate associations with full-text publication, where sensitivity, specificity, and AUC were logit transformed, and DOR was log transformed. A full-text publication was found for 226/399 (57%) included abstracts. There was no association between reported estimates of sensitivity and full-text publication (hazard ratio [HR] 1.09 [95% confidence interval {CI} 0.98, 1.22]). The same applied to specificity (HR 1.00 [95% CI 0.88, 1.14]), AUC (HR 0.91 [95% CI 0.75, 1.09]), and DOR (HR 1.01 [95% CI 0.94, 1.09]). Almost half of the ARVO conference abstracts describing diagnostic accuracy studies did not reach full-text publication. Studies in abstracts that mentioned higher accuracy estimates were not more likely to be reported in a full-text publication. Copyright © 2016 Elsevier Inc. All rights reserved.

  9. Nordic research in ophthalmology

    DEFF Research Database (Denmark)

    Stefánsson, Einar; Zetterström, Charlotta; Ehlers, Niels

    2003-01-01

    Ophthalmology, eye research, cornea, catarcat, paediatric ophthalmology, glaucoma, diabetic eye disease, age-related macular degeneration, ophthalmic oncology......Ophthalmology, eye research, cornea, catarcat, paediatric ophthalmology, glaucoma, diabetic eye disease, age-related macular degeneration, ophthalmic oncology...

  10. International patenting in ophthalmology: An analysis of its structure and relevance for the development of drugs and diagnostics

    Directory of Open Access Journals (Sweden)

    Hermann AM Mucke

    2008-10-01

    Full Text Available Hermann AM Mucke, Peter Mucke, Eva MuckeHM Pharma Consultancy, Vienna, AustriaAbstract: While investigative ophthalmologists access peer-reviewed journals as part of their daily routine, and while they regularly visit scientific congresses, they rarely peruse patent documents as an information source. Among the reasons for this negligence are the incompatibility of patent search algorithms with those known from journal databases, a legalistic and frequently redundant language, and misconceptions about the nature of the patenting system. Here we present key data and analyses from the ophthalmology module of a patent database system that we are developing to address some of these problems. We show that international patent applications consistently reflect developer interest in the ocular drug and diagnostics field; that they are technically focused lead indicators of developments that frequently feature in peer-reviewed patenting only much later; and that patenting targets are well aligned with the unmet therapeutic needs of populations in industrialized countries. Most applications (74%–78% in years since 2006 are supported with experimental data, and most (on average, 80%–90% faced at least one objection to patentability during their initial stage of examination. In contrast to the peer-reviewed scenery that is highly diverse, the corresponding patenting arena shows a pronounced focus on the United States.Keywords: ophthalmology, eye diseases, iontophoresis, intellectual property, patents as topic, bibliographic databases

  11. Neuro-ophthalmology as a career.

    Science.gov (United States)

    Spitze, Arielle; Al-Zubidi, Nagham; Lam, Peter; Yalamanchili, Sushma; Lee, Andrew G

    2014-10-01

    This essay was written to discuss the reasoning behind the personal decisions made by 2 current neuro-ophthalmology fellows to pursue neuro-ophthalmology as a career. It is meant to enlighten the reader about what role neuro-ophthalmologists play in clinical practice, what makes neuro-ophthalmology unique to all other sub-specialties, and how this contributes to making neuro-ophthalmology not only one of the most medically interesting, yet rewarding sub-specialties in ophthalmology.

  12. [Scientific role of German ophthalmology in the European telecommunication project OPHTEL].

    Science.gov (United States)

    Mertz, M; Mann, G; Zahlmann, G; Obermaier, M

    1997-07-01

    In Denmark, France, Germany, Great Britain and Italy, the OPHTEL project combines clinical centers of ophthalmology and internal medicine, an institute for medical informatics and health services research, a publishing company and different industrial partners in the EDP market. With the aid of visual telecommunication and rapid data transfer, methods and conditions will be developed and proved so that any physician can very easily obtain sufficient information for treating his patient. Thus, the regional differences in the quality of structured health service (e.g., urban/ rural) will be overcome throughout Europe. SCIENTIFIC TASKS: A multilingual diagnostic and therapeutic thesaurus has to be worked out in order to create standards for communication and quality control. Based on literature, images and image analysis in a knowledge-based data bank, a monitoring system (containing watch-dog functions) and the basic aspects of an ophthalmological patient/disease register will be investigated. (In parallel, a technical development of synchronous and asynchronous telecommunication between eye physicians is taking place in close cooperation with the regional Bavarian project Teleopathalmology in Bavaria on-line). State of the art 6 months after starting the project:the knowledge-based image data bank has been founded and also an ophthalmological 8 language thesaurus and definition standard. All data transfer lines are installed. The project is taking place amid diverging sections of medicine: ophthalmology and internal medicine, health politics and data protection, individual treatment and common interest (health care), product management and office organization. Thus, the scientific quality of the transferred ophthalmological content must undergo sophisticated controls. FUTURE STEPS: Intense cooperation with the big German associations for ophthalmology (DOG, BVA) and the European ophthalmological societies concerning EDP, classification and quality control.

  13. Indications for and techniques of keratoplasty at Vietnam National Institute of Ophthalmology

    Directory of Open Access Journals (Sweden)

    Pham Ngoc Dong

    2016-03-01

    Full Text Available AIM: To report the indications for and techniques of corneal transplantation at Vietnam National Institute of Ophthalmology (VNIO over a period of 12y (2002-2013. METHODS: Records of patients who had undergone corneal transplantation at VNIO from January 1, 2002 to January 1, 2014 were reviewed to determine the indication for and type of corneal transplant performed. Patient age, gender, indication for corneal transplantation and surgical technique were recorded and analyzed. RESULTS: Corneal transplantation were underwent in 1390 eyes of 1278 patients with a mean age of 44.9±18.1y during the period under review. The most common indication was infectious corneal ulcer (n=670; 48.2%, followed by corneal scar (n=333, 24.0%, corneal dystrophy (n=138, 9.9% and failed graft (n=112, 8.1%. Nearly all procedures performed were penetrating keratoplasty (n=1300, 93.5%, with a few lamellar keratoplasty procedures performed: lamellar keratoplasty (n=52, 3.7%, Descemet’s stripping automated endothelial keratoplasty (n=27, 1.9% and deep anterior lamellar keratoplasty (n=11, 0.8%. CONCLUSION: While the most common indication for keratoplasty was infectious keratitis, nearly all indications for corneal transplantation were managed with penetrating keratoplasty. However, lamellar keratoplasty techniques, including deep anterior lamellar keratoplasty and Descemet’s stripping automated endothelial keratoplasty, are being performed with increasing frequency for isolated stromal and endothelial disorders, respectively.

  14. A pilot trial of tele-ophthalmology for diagnosis of chronic blurred vision.

    Science.gov (United States)

    Tan, Johnson Choon Hwai; Poh, Eugenie Wei Ting; Srinivasan, Sanjay; Lim, Tock Han

    2013-02-01

    We evaluated the accuracy of tele-ophthalmology in diagnosing the major causes of chronic blurring of vision. Thirty consecutive patients attending a primary eye-care facility in Singapore (the Ang Mo Kio Polyclinic, AMKP) with the symptom of chronic blurred vision were recruited. An ophthalmic technician was trained to perform Snellen acuity; auto-refraction; intraocular pressure measurement; red-colour perimetry; video recordings of extraocular movement, cover tests and pupillary reactions; and anterior segment and fundus photography. Digital information was transmitted to a tertiary hospital in Singapore (the Tan Tock Seng Hospital) via a tele-ophthalmology system for teleconsultation with an ophthalmologist. The diagnoses were compared with face-to-face consultation by another ophthalmologist at the AMKP. A user experience questionnaire was administered at the end of the consultation. Using face-to-face consultation as the gold standard, tele-ophthalmology achieved 100% sensitivity and specificity in diagnosing media opacity (n = 29), maculopathy (n = 23) and keratopathy (n = 30) of any type; and 100% sensitivity and 92% specificity in diagnosing optic neuropathy of any type (n = 24). The majority of the patients (97%) were satisfied with the tele-ophthalmology workflow and consultation. The tele-ophthalmology system was able to detect causes of chronic blurred vision accurately. It has the potential to deliver high-accuracy diagnostic eye support to remote areas if suitably trained ophthalmic technicians are available.

  15. Ophthalmologic identification of cerebral malaria in adults

    Directory of Open Access Journals (Sweden)

    Pedrosa, Catarina Areias

    2015-11-01

    Full Text Available Objective: To report the clinical presentation of malarial retinopathy in an adult, emphasizing the importance of this diagnosis for the clinical suspicion and prognosis of cerebral malaria. Methods: A 39-year-old caucasian man presented with hemolytic anemia, thrombocytopenia, acidemia and acute renal failure, developing severe encephalopathy. The diagnosis of malaria was done and after systemic stabilization, the patient noticed a central scotoma in the left eye. Ophthalmological examination revealed retinal features of malarial retinopathy. Results: At one-month follow-up, the patient had improved his systemic condition and the left eye scotoma had disappeared. Visual acuity was 20/20 in both eyes and on examination almost all lesions had regressed. Conclusion: Malarial retinopathy is a diagnostic factor and a prognosis indicator of severe infection, usually with brain involvement. The knowledge of the ophthalmological features associated with severe malaria, which is more frequent in children but can also occur in adults, becomes imperative in order to reduce the risk of neurologic sequelae and associated mortality.

  16. Optical coherence tomography--a new imaging method in ophthalmology.

    Science.gov (United States)

    Svorenova, I; Strmen, P; Olah, Z

    2010-01-01

    An improvement of examination methods in ophthalmology, technical digitalisation and knowledge of validity of examinations in various diseases contributes to early diagnostics, thereby leading to an opportunity for early treatment of eye disorders. Standard introduction of the so-called optical coherence tomography into the ophthamological clinical practice facilitated new options for a detailed analysis of pathological processes in the particular layers of the retina (Fig. 2, Ref. 5). Full Text (Free, PDF) www.bmj.sk.

  17. The clinical neuro-ophthalmology of vision

    International Nuclear Information System (INIS)

    Kashii, Satoshi

    2008-01-01

    To diagnose a patient with a failing visual system, it is necessary to localize the site of the lesion in the system, and identify the etiology that has produced it. Physicians do not see diseases but just their manifestations. Clinical neuro-ophthalmology provides the basic principles on how to progress from manifestations to the diseases they indicate. The Frank B. Walsh Neuro-Ophthalmology Society (the Walsh Society) that originated in 1969 in the United States has been the center of clinical neuro-ophthalmology case studies throughout the world. In Japan, the Ronald M. Burde Clinical Neuro-Ophthalmology Study Group (the RMB Society) was organized in 2001 to establish and promote a clinicopathologic conference in the style of the Walsh Society. On this occasion, Prof. Burde was invited to the Annual Japanese Ophthalmological Society meeting. Based on some illustrative cases presented at the annual meetings of the RMB society, this review was carried out to present the current knowledge of clinical neuro-ophthalmology. (author)

  18. An Aid to Neuro-Ophthalmology

    OpenAIRE

    Akram, Muhammad

    2011-01-01

    Muhammad Shoaib AkramDepartment of Ophthalmology, King Fahad Military Hospital, Khamis Mushyat, Saudi ArabiaNeuro-ophthalmology is a very interesting field. Localizing a lesion in various pathways can be challenging, particularly for beginners. One needs a solid foundation of the neuro-anatomy of visual pathways to enhance understanding. The author aims to provide medical students and residents with the basic concepts of neuro-ophthalmology. This text attempts to simplify the complex problems...

  19. Intracranial Aneurysms of Neuro-Ophthalmologic Relevance.

    Science.gov (United States)

    Micieli, Jonathan A; Newman, Nancy J; Barrow, Daniel L; Biousse, Valérie

    2017-12-01

    Intracranial saccular aneurysms are acquired lesions that often present with neuro-ophthalmologic symptoms and signs. Recent advances in neurosurgical techniques, endovascular treatments, and neurocritical care have improved the optimal management of symptomatic unruptured aneurysms, but whether the chosen treatment has an impact on neuro-ophthalmologic outcomes remains debated. A review of the literature focused on neuro-ophthalmic manifestations and treatment of intracranial aneurysms with specific relevance to neuro-ophthalmologic outcomes was conducted using Ovid MEDLINE and EMBASE databases. Cavernous sinus aneurysms were not included in this review. Surgical clipping vs endovascular coiling for aneurysms causing third nerve palsies was compared in 13 retrospective studies representing 447 patients. Complete recovery was achieved in 78% of surgical patients compared with 44% of patients treated with endovascular coiling. However, the complication rate, hospital costs, and days spent in intensive care were reported as higher in surgically treated patients. Retrospective reviews of surgical clipping and endovascular coiling for all ocular motor nerve palsies (third, fourth, or sixth cranial nerves) revealed similar results of complete resolution in 76% and 49%, respectively. Improvement in visual deficits related to aneurysmal compression of the anterior visual pathways was also better among patients treated with clipping than with coiling. The time to treatment from onset of visual symptoms was a predictive factor of visual recovery in several studies. Few reports have specifically assessed the improvement of visual deficits after treatment with flow diverters. Decisions regarding the choice of therapy for intracranial aneurysms causing neuro-ophthalmologic signs ideally should be made at high-volume centers with access to both surgical and endovascular treatments. The status of the patient, location of the aneurysm, and experience of the treating physicians

  20. Neuro-ophthalmology | Bekibele | Nigerian Journal of Ophthalmology

    African Journals Online (AJOL)

    Nigerian Journal of Ophthalmology. Journal Home · ABOUT THIS JOURNAL · Advanced Search · Current Issue · Archives · Journal Home > Vol 23, No 3 (2015) >. Log in or Register to get access to full text downloads.

  1. Diagnostic imaging in ophthalmology

    International Nuclear Information System (INIS)

    Gonzalez, C.F.; Becker, M.H.; Flanagan, J.C.

    1986-01-01

    There are three sections in the book. The first section is a discussion of imaging techniques, which includes plain film radiography and multidirectional tomography of the orbit, computed tomography (CT) of the orbit and its use in the evaluation of ocular motility disorders, ultrasonography of the eye and orbit, investigation of the orbit by contrast techniques (which includes a brief review of angiography), the lachrimal drainage system, foreign body localization, and magnetic resonance imaging of the eye and orbit. There is extensive discussion of CT throughout the book. The second section is devoted to the role of these imaging methods in the evaluation of ophthalmic disorders. A discussion of congenital anomalies is useful for those centers that are exposed to unusual congenital anomalies and syndromes. Also included is evaluation of exophthalmous and thyroid ophthamalopathy, orbital tumors, lesions involving the visual pathways, CT assessment of paraorbital pathology (including basal and squamous cell tumors of the face), infection of the orbit, and orbital trauma. The third section is an overview of radiation therapy and malignant intraoccular tumors

  2. Neuro-ophthalmology | Bekibele | Nigerian Journal of Ophthalmology

    African Journals Online (AJOL)

    Transactions of the Ophthalmological Society of Nigeria: Proceedings of the annual OSN Conference, Jos, Nigeria, August 25–28, 2015. Full Text: EMAIL FREE FULL TEXT EMAIL FREE FULL TEXT · DOWNLOAD FULL TEXT DOWNLOAD FULL TEXT · AJOL African Journals Online. HOW TO USE AJOL... for Researchers ...

  3. Neuro-ophthalmology and neuro-otology update.

    Science.gov (United States)

    Gold, Daniel R; Zee, David S

    2015-12-01

    This review summarizes topical papers from the fields of neuro-ophthalmology and neuro-otology published from August 2013 to February 2015. The main findings are: (1) diagnostic criteria for pseudotumor cerebri have been updated, and the Idiopathic Intracranial Hypertension Treatment Trial evaluated the efficacy of acetazolamide in patients with mild vision loss, (2) categorization of vestibular disorders through history and ocular motor examination is particularly important in the acute vestibular syndrome, where timely distinction between a central or peripheral localization is essential, (3) the newly described "sagging eye syndrome" provides a mechanical explanation for an isolated esodeviation that increases at distance in the aging population and (4) eye movement recordings better define how cerebellar dysfunction and/or sixth nerve palsy may play a role in other patients with esodeviations that increase at distance.

  4. The Global Education Network for Retinopathy of Prematurity (Gen-Rop): Development, Implementation, and Evaluation of A Novel Tele-Education System (An American Ophthalmological Society Thesis).

    Science.gov (United States)

    Chan, R V Paul; Patel, Samir N; Ryan, Michael C; Jonas, Karyn E; Ostmo, Susan; Port, Alexander D; Sun, Grace I; Lauer, Andreas K; Chiang, Michael F

    2015-01-01

    To describe the design, implementation, and evaluation of a tele-education system developed to improve diagnostic competency in retinopathy of prematurity (ROP) by ophthalmology residents. A secure Web-based tele-education system was developed utilizing a repository of over 2,500 unique image sets of ROP. For each image set used in the system, a reference standard ROP diagnosis was established. Performance by ophthalmology residents (postgraduate years 2 to 4) from the United States and Canada in taking the ROP tele-education program was prospectively evaluated. Residents were presented with image-based clinical cases of ROP during a pretest, posttest, and training chapters. Accuracy and reliability of ROP diagnosis (eg, plus disease, zone, stage, category) were determined using sensitivity, specificity, and the kappa statistic calculations of the results from the pretest and posttest. Fifty-five ophthalmology residents were provided access to the ROP tele-education program. Thirty-one ophthalmology residents completed the program. When all training levels were analyzed together, a statistically significant increase was observed in sensitivity for the diagnosis of plus disease, zone, stage, category, and aggressive posterior ROP (Peducation system for ROP education is effective in improving diagnostic accuracy of ROP by ophthalmology residents. This system may have utility in the setting of both healthcare and medical education reform by creating a validated method to certify telemedicine providers and educate the next generation of ophthalmologists.

  5. Selection of suitable diagnostic techniques for an RF atmospheric pressure plasma

    International Nuclear Information System (INIS)

    Kong, M.G.; Deng, X.T.

    2001-01-01

    As an early report of our study, this paper summaries the RF atmospheric pressure plasma system we intend to characterize and a number of diagnostic techniques presently under assessment for our plasma rig. By discussing the advantages and disadvantages of these diagnostic techniques at this meeting, we hope to gain feedback and comments to improve our choice of appropriate diagnostic techniques as well as our subsequent application of these techniques to nonthermal RF atmospheric pressure plasmas

  6. Caring for academic ophthalmology in Croatia.

    Science.gov (United States)

    Mandić, Zdravko; Vatavuk, Zoran

    2004-06-01

    Like any other area of academic medicine in Croatia, academic ophthalmology has always been limited by or has depended on the factors outside the profession itself: during the communist regime, it was mostly political and ideological correctness of academic ophthalmologists, and today during the social and economic transition, it is the lack of finances, planning, and sophisticated technology. The four university eye clinics, which are the pillars of academic ophthalmology in Croatia, provide health care to most difficult cases, educate students, residents, and specialists, and do research. On the other hand, they lack equipment, room, and financial recognition. This ever growing imbalance between requirements imposed on academic ophthalmology today and its possibilities make it less and less attractive, especially in comparison with private practice. The possible solution lies in increasing the independence of ophthalmology from pharmaceutical industry and politics, especially in research and financial aspects.

  7. Development of process diagnostic techniques for piping and equipment

    International Nuclear Information System (INIS)

    Yotsutsuji, Mitoshi

    1987-01-01

    The thing required for using the facilities composing a plant for a long period without anxiety is to quantitatively grasp the quantities of the present condition of the facilities and to take the necessary measures beforehand. For this purpose, the diagnostic techniques for quickly and accurately detect the quantities of the condition of facilities are necessary, and the development of process diagnostic techniques has been desired. The process diagnostic techniques mentioned here mean those for diagnosing the contamination, clogging and performance of towers, tanks, heat exchangers and others. Idemitsu Engineering Co. had developed a simplified diagnostic equipment for detecting the state of fouling in piping in 1982, which is the gamma ray transmission diagnosis named Scale Checker. By further improving it, the process diagnostic techniques for piping and equipment were developed. In this report, the course of development and examination, the principle of detection, the constitution and the examination of remodeling of the Scale Checker are reported. As the cases of process diagnosis in plant facilities, the diagnosis of the clogging in process piping and the diagnosis of the performance of a distillation tower were carried out. The contents of the diagnosis and the results of those cases are explained. (Kako, I.)

  8. Investigating the perception of Romanian adults on ophthalmology services from an experiential marketing perspective.

    Science.gov (United States)

    Gheorghe, Consuela-Mădălina; Gheorghe, Iuliana-Raluca; Purcărea, Victor Lorin

    2017-01-01

    Nowadays, we live in a world in which we are daily bombed by hundreds of advertisements. Specialists have to discover other channels or embed attractive elements in the advertisements' messages to cut through the clutter and catch the consumers' attention. The evolution of the concept of service has changed from the commercial status to determining a lifestyle. Buying a service has led to a change in the consumer behavior. Consumers want to buy services that dazzle their senses, touch their hearts, and stimulate their minds, not as before, excellent or satisfying. Ophthalmology is the medical specialty that is the most oriented toward outpatient care, as hospitalization is required only in a small percentage of cases. The objective of this case study was to investigate the perception of Romanian adult consumers on ophthalmology services from an experiential marketing perspective, by using the Focus Group method. Ophthalmology requires a wide range of skills due to the diversity of consumers who demand specialized consultations. Experiential marketing is a valuable strategy that ophthalmologic organizations may use to target specific consumers. The purpose of this case study was to identify the perceptions of Romanian adults on experiential marketing campaigns and determine the degree to which these campaigns influenced their decisions of buying an ophthalmologic service. Using a snowball sampling technique we have sent a filter questionnaire to 40 people on the internet. The filter questionnaire consisted of questions about wearing eyeglasses, the period of wearing them, the last ophthalmologic consultation, the type of ophthalmologic clinic they were going to, age and education. The respondents revealed there is almost no visibility on promoting services even if there is an upsurge of organizations offering this type of health service in the Romanian ophthalmology sector.

  9. Investigating the perception of Romanian adults on ophthalmology services from an experiential marketing perspective

    Science.gov (United States)

    Gheorghe, Consuela-Mădălina; Gheorghe, Iuliana-Raluca; Purcărea, Victor Lorin

    2017-01-01

    Nowadays, we live in a world in which we are daily bombed by hundreds of advertisements. Specialists have to discover other channels or embed attractive elements in the advertisements’ messages to cut through the clutter and catch the consumers’ attention. The evolution of the concept of service has changed from the commercial status to determining a lifestyle. Buying a service has led to a change in the consumer behavior. Consumers want to buy services that dazzle their senses, touch their hearts, and stimulate their minds, not as before, excellent or satisfying. Ophthalmology is the medical specialty that is the most oriented toward outpatient care, as hospitalization is required only in a small percentage of cases. The objective of this case study was to investigate the perception of Romanian adult consumers on ophthalmology services from an experiential marketing perspective, by using the Focus Group method. Ophthalmology requires a wide range of skills due to the diversity of consumers who demand specialized consultations. Experiential marketing is a valuable strategy that ophthalmologic organizations may use to target specific consumers. The purpose of this case study was to identify the perceptions of Romanian adults on experiential marketing campaigns and determine the degree to which these campaigns influenced their decisions of buying an ophthalmologic service. Using a snowball sampling technique we have sent a filter questionnaire to 40 people on the internet. The filter questionnaire consisted of questions about wearing eyeglasses, the period of wearing them, the last ophthalmologic consultation, the type of ophthalmologic clinic they were going to, age and education. The respondents revealed there is almost no visibility on promoting services even if there is an upsurge of organizations offering this type of health service in the Romanian ophthalmology sector. PMID:29450395

  10. TECHNIQUES OF EVALUATION OF HEMOGLOBIN OXYGEN SATURATION IN CLINICAL OPHTHALMOLOGY

    Directory of Open Access Journals (Sweden)

    S. Yu. Petrov

    2016-01-01

    Full Text Available Oxygen content in body fluids and tissues is an important indicator of life support functions. A number of ocular pathologies, e.g. glaucoma, are of presumable vascular origin which means altered blood supply and oxygen circulation. Most oxygen is transported in the blood in the association with hemoglobin. When passing through the capillaries, hemoglobin releases oxygen, converting from oxygenated form to deoxygenated form. This process is accompanied by the changes in spectral characteristics of hemoglobin which result in different colors of arterial and venous blood. Photometric technique for the measurement of oxygen saturation in blood is based on the differences in light absorption by different forms of hemoglobin. The measurement of saturation is called oximetry. Pulse oximetry with assessment of tissue oxygenation is the most commonly used method in medicine. The degree of hemoglobin oxygen saturation in the eye blood vessels is the most accessible for noninvasive studies during ophthalmoscopy and informative. Numerous studies showed the importance of this parameter for the diagnosis of retinopathy of various genesis, metabolic status analysis in hyperglycemia, diagnosis and control of treatment of glaucoma and other diseases involving alterations in eye blood supply. The specific method for evaluation of oxygen concentration is the measurement of pressure of oxygen dissolved in the blood, i.e. partial pressure of oxygen. In ophthalmological practice, this parameter is measured in anterior chamber fluid evaluating oxygen level for several ophthalmopathies including different forms of glaucoma, for instillations of hypotensive eye drops as well as in vitreous body near to the optic disc under various levels of intraocular pressure. Currently, monitoring of oxygen saturation in retinal blood vessels, i.e. retinal oximetry, is well developed. This technique is based on the assessment of light absorption by blood depending on

  11. Progress in diagnostic techniques for sc cavities

    International Nuclear Information System (INIS)

    Reece, C.E.

    1988-01-01

    While routinely achieved performance characteristics of superconducting cavities have now reached a level which makes them useful in large scale applications, achieving this level has come only through the knowledge gained by systematic studies of performance limiting phenomena. Despite the very real progress that has been made, the routine performance of superconducting cavities still falls far short of both the theoretical expectations and the performance of a few exception examples. It is the task of systematically applied diagnostic techniques to reveal additional information concerning the response of superconducting surfaces to applied RF fields. Here recent developments in diagnostic techniques are discussed. 18 references, 12 figures

  12. [Citation analysis of originals in Chinese Journal of Ophthalmology].

    Science.gov (United States)

    Cai, Lian

    2002-09-01

    To evaluate the academic level and the popularity of Chinese Journal of Ophthalmology. According to the information of Chinese science and technology papers and citation database (CSTPC), I statistically analyzed the amount and distribution of the originals in Chinese Journal of Ophthalmology cited by the journals included by CSTPC. The originals of Chinese Journal of Ophthalmology were high-qualified and influential, and their authors were all over the country. With the unique style and character, Chinese Journal of Ophthalmology is the main medical core periodical and one of the most important information resources in the field of ophthalmology in China.

  13. Tests for malingering in ophthalmology

    Directory of Open Access Journals (Sweden)

    Ali Ihsan Incesu

    2013-10-01

    Full Text Available Simulation can be defined as malingering, or sometimes functional visual loss (FVL. It manifests as either simulating an ophthalmic disease (positive simulation, or denial of ophthalmic disease (negative simulation. Conscious behavior and compensation or indemnity claims are prominent features of simulation. Since some authors suggest that this is a manifestation of underlying psychopathology, even conversion is included in this context. In today’s world, every ophthalmologist can face with simulation of ophthalmic disease or disorder. In case of simulation suspect, the physician’s responsibility is to prove the simulation considering the disease/disorder first, and simulation as an exclusion. In simulation examinations, the physician should be firm and smart to select appropriate test(s to convince not only the subject, but also the judge in case of indemnity or compensation trials. Almost all ophthalmic sensory and motor functions including visual acuity, visual field, color vision and night vision can be the subject of simulation. Examiner must be skillful in selecting the most appropriate test. Apart from those in the literature, we included all kinds of simulation in ophthalmology. In addition, simulation examination techniques, such as, use of optical coherence tomography, frequency doubling perimetry (FDP, and modified polarization tests were also included. In this review, we made a thorough literature search, and added our experiences to give the readers up-to-date information on malingering or simulation in ophthalmology.

  14. System of the ophthalmologic help premature children with retinopathy of prematurity in the Central region of Russia

    Directory of Open Access Journals (Sweden)

    A. V. Tereshchenko

    2012-01-01

    Full Text Available Purpose: Functional results analysis of ophthalmologic help system for premature infants, which includes the full cycle of early revelation, treatment and regular medical check-up activities for patients with ROP in Central region of Russia.Methods: Fields for ROP screening were performed in premature infants medical care units by clinic specialists. Infants with re- vealed ROP were directed to Kaluga Branch of IRtC «Eye Microsurgery» for detailed diagnostic examination and subsequent treatment and monitoring.Results: In 2003-2011 454 fields in Kaluga, tula, Bryansk, and Orel regions were made. 8861 infants were examined. ROP was found in 1834 infants (20.7%. 823 different interventions for infants with active ROP were performed: 737 retinal lasercoagulations, 3-ports vitrectomy — 72, lensvitrectomy — 14. the total efficacy of the treatment was 92.9%.Conclusion: the ophthalmologic help system for premature infants in Central region of Russia combines all directions from de-tailed diagnostic to hich-technology treatment. It allows to reproduce one all over the Russian Federation territory.

  15. System of the ophthalmologic help premature children with retinopathy of prematurity in the Central region of Russia

    Directory of Open Access Journals (Sweden)

    A. V. Tereshchenko

    2014-07-01

    Full Text Available Purpose: Functional results analysis of ophthalmologic help system for premature infants, which includes the full cycle of early revelation, treatment and regular medical check-up activities for patients with ROP in Central region of Russia.Methods: Fields for ROP screening were performed in premature infants medical care units by clinic specialists. Infants with re- vealed ROP were directed to Kaluga Branch of IRtC «Eye Microsurgery» for detailed diagnostic examination and subsequent treatment and monitoring.Results: In 2003-2011 454 fields in Kaluga, tula, Bryansk, and Orel regions were made. 8861 infants were examined. ROP was found in 1834 infants (20.7%. 823 different interventions for infants with active ROP were performed: 737 retinal lasercoagulations, 3-ports vitrectomy — 72, lensvitrectomy — 14. the total efficacy of the treatment was 92.9%.Conclusion: the ophthalmologic help system for premature infants in Central region of Russia combines all directions from de-tailed diagnostic to hich-technology treatment. It allows to reproduce one all over the Russian Federation territory.

  16. HINT for Squint: A Computer Reliant Diagnostic Aid for Strabismus

    OpenAIRE

    Gieszl, Louis R.; Morris, Jacqueline; Guyton, David L.

    1983-01-01

    This paper provides an outline of methods used for the implementation of a computer reliant diagnostic aid in the medical specialty of Ophthalmology. Some problems have been associated with many previous diagnostic models. A careful review indicates that the most serious problems were:

  17. Alternative diagnostic technique for carpal tunnel syndrome

    International Nuclear Information System (INIS)

    Hayakawa, Katsuhiko; Nakane, Takashi; Kobayashi, Shigeru; Shibata, Kunio

    2002-01-01

    Compressive and entrapment neuropathies are common clinical syndromes characterized by neurologic deficits due to mechanical or dynamic compression of peripheral nerves. However, the definitive diagnosis based on clinical symptoms alone is difficult in many cases, and the electrophysiological diagnostic method is solely used as a supplementary diagnostic method at present. As a new diagnostic method for entrapment neuropathy, the present study investigated the usefulness of gadolinium-enhanced MRI in carpal tunnel syndrome. On enhanced MRI of idiopathic carpal tunnel syndrome, contrast-enhancement in the median nerve was found in 30 of 34 hands (88.2%). Enhanced MRI allows to visualize intraneural edema in the nerve easily on the naked eye. Therefore, this technique supplied useful information for making definitive diagnosis and is promising as a non-invasive diagnostic method for entrapment neuropathy. (author)

  18. Alternative diagnostic technique for carpal tunnel syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Hayakawa, Katsuhiko; Nakane, Takashi [Aiko Orthopaedic Hospital, Nagoya (Japan); Kobayashi, Shigeru; Shibata, Kunio [Fujita Health Univ., Toyoake, Aichi (Japan). School of Medicine

    2002-10-01

    Compressive and entrapment neuropathies are common clinical syndromes characterized by neurologic deficits due to mechanical or dynamic compression of peripheral nerves. However, the definitive diagnosis based on clinical symptoms alone is difficult in many cases, and the electrophysiological diagnostic method is solely used as a supplementary diagnostic method at present. As a new diagnostic method for entrapment neuropathy, the present study investigated the usefulness of gadolinium-enhanced MRI in carpal tunnel syndrome. On enhanced MRI of idiopathic carpal tunnel syndrome, contrast-enhancement in the median nerve was found in 30 of 34 hands (88.2%). Enhanced MRI allows to visualize intraneural edema in the nerve easily on the naked eye. Therefore, this technique supplied useful information for making definitive diagnosis and is promising as a non-invasive diagnostic method for entrapment neuropathy. (author)

  19. The application of laser plasma in ophthalmology

    International Nuclear Information System (INIS)

    He Yujiang; Luo Le; Sun Yabing

    2000-01-01

    The production and development of laser plasma are introduced, and the contribution of laser biomedicine and laser plasma technology to ophthalmology is analyzed. The latest three progresses (laser photocoagulation, photo-refractive keratotomy and laser iridectomy) of laser plasma applications in ophthalmology are presented

  20. Medical X-ray techniques in diagnostic radiography. 4. ed.

    International Nuclear Information System (INIS)

    Plaats, G.J. van der; Vijlbrief, P.

    1980-01-01

    A step by step account is given of every aspect of the technical factors involved in the production of X-ray images. Chapter titles include, methods of image formation and laws of projection, sharpness and unsharpness, contrast, perceptibility of detail in the radiographic image-image quality, properties of fluoroscopic screens, radiographic films, intensifying screens and cassettes, image intensification and X-ray television, processing technique, fluoroscopy and radiographic technique in general, special radiographic techniques, radiographic examinations using contrast media, exposure and exposure tables and automatic density control, diagnostic X-ray apparatus, and diagnostic stands and accessories. (C.F.)

  1. Effectiveness of relaxation techniques before diagnostic screening of cancer patients

    Directory of Open Access Journals (Sweden)

    Montserrat Aiger

    2016-07-01

    Full Text Available Psychophysiological arousal was observed in cancer patients during the application of relaxation techniques prior to a diagnostic scan (PET-CT. The aim of the study is twofold: firstly, it is sought to establish whether such techniques can minimize patient arousal before diagnostic screening begins, and secondly to measure which of them are most effective. The dependent variable is electrodermal activity, recording the attentional level and emotional response, and the independent variable comprises the relaxation techniques used, namely Jacobson, breathing and visualization. The 39 patients were split into experimental groups to whom the relaxation techniques (Jacobson, breathing exercises, and visualization were applied before they went for the PET-CT. An activity-module procedure was applied to track electrodermal activity during the relaxation sessions, consisting of instructions, timeout; wait, task; relaxation and end of the recording session. The control group received no relaxation techniques before the PET-CT. Session-end results show that patients who perform relaxation techniques achieve greater attentional focus using Jacobson's technique (M = .212 and enhanced emotional containment using visualization (M = .206. It is concluded that relaxation techniques minimize the state of activation during the waiting period before a diagnostic scan.

  2. The Global Education Network for Retinopathy of Prematurity (Gen-Rop): Development, Implementation, and Evaluation of A Novel Tele-Education System (An American Ophthalmological Society Thesis)

    Science.gov (United States)

    Chan, R.V. Paul; Patel, Samir N.; Ryan, Michael C.; Jonas, Karyn E.; Ostmo, Susan; Port, Alexander D.; Sun, Grace I.; Lauer, Andreas K.; Chiang, Michael F.

    2015-01-01

    Purpose: To describe the design, implementation, and evaluation of a tele-education system developed to improve diagnostic competency in retinopathy of prematurity (ROP) by ophthalmology residents. Methods: A secure Web-based tele-education system was developed utilizing a repository of over 2,500 unique image sets of ROP. For each image set used in the system, a reference standard ROP diagnosis was established. Performance by ophthalmology residents (postgraduate years 2 to 4) from the United States and Canada in taking the ROP tele-education program was prospectively evaluated. Residents were presented with image-based clinical cases of ROP during a pretest, posttest, and training chapters. Accuracy and reliability of ROP diagnosis (eg, plus disease, zone, stage, category) were determined using sensitivity, specificity, and the kappa statistic calculations of the results from the pretest and posttest. Results: Fifty-five ophthalmology residents were provided access to the ROP tele-education program. Thirty-one ophthalmology residents completed the program. When all training levels were analyzed together, a statistically significant increase was observed in sensitivity for the diagnosis of plus disease, zone, stage, category, and aggressive posterior ROP (P<.05). Statistically significant changes in specificity for identification of stage 2 or worse (P=.027) and pre-plus (P=.028) were observed. Conclusions: A tele-education system for ROP education is effective in improving diagnostic accuracy of ROP by ophthalmology residents. This system may have utility in the setting of both healthcare and medical education reform by creating a validated method to certify telemedicine providers and educate the next generation of ophthalmologists. PMID:26538772

  3. Significance of head CT in neuro-ophthalmology

    International Nuclear Information System (INIS)

    Nishimoto, Yuichiro; Masuyama, Yoshimasa; Nakamura, Yasuko; Fujimoto, Toshiro.

    1979-01-01

    It is important to perform CT purposefully in patients with some neuro-ophthalmological disorders. Using Hitachi CT-H250 with the finer matrix of 256 x 256 and a section thickness of 5 mm and 10 mm, we performed head CT in 98 patients with various kinds of neuro-ophthalmological disorders in these 30 months. Neuro-ophthalmological findings in these patients were visual disturbance, visual field defects (hemianopsia, quandrantanopsia, enlargement of the blind spot, central scotoma), papilledema, optic nerve atrophy, difficulties in ocular movements, and others. In 44 (44.9%) of these 98 patients, abnormal findings were displayed in the head CT, characterizing intracranial tumors, intracranial infarction, aneurysms in intracranial vessels, arterio-venous malformation, enlargement of the ventricle or the cistern. In some cases the head CT was the decisive procedure in ensuring a correct diagnosis. We presented findings in the head CT in several interesting cases. We recognized the necessity of the head CT in patients with neuro-ophthalmological disorders. (author)

  4. Ophthalmologic abnormalities among deaf students in Kaduna ...

    African Journals Online (AJOL)

    ... syndrome (0.6%) and Ushers syndrome (0.6%). Refractive error was the most common (7.9%). Conclusion: Since these deaf students use their sight to compensate for the deafness, routine ophthalmologic examination should be carried out on them so that ophthalmologic abnormalities are detected early and treatment ...

  5. Ophthalmologic complications of systemic disease.

    Science.gov (United States)

    Klig, Jean E

    2008-02-01

    The human eye, as an organ, can offer critical clues to the presence of systemic disease. This article discusses the various ophthalmologic manifestations of systemic disease that can be evident on examination by an emergency department provider, as well as some findings that can be discerned with specialty consultation. The following topics are reviewed with respect to potential ocular signs and complications: syphilis, herpes zoster, Lyme disease, acquired immunodeficiency syndrome, Reiter's syndrome, Kawasaki's disease, temporal arteritis, endocarditis, hypertension, and diabetes mellitus. Indications for emergent ophthalmologic consultation are also emphasized.

  6. Clinical trials in Brazilian journals of ophthalmology: where we are.

    Science.gov (United States)

    Lira, Rodrigo Pessoa Cavalcanti; Leal, Franz Schubert; Gonçalves, Fauze Abdulmassih; Amorim, Fernando Henrique Ramos; Felix, João Paulo Fernandes; Arieta, Carlos Eduardo Leite

    2013-01-01

    To compare clinical trials published in Brazilian journals of ophthalmology and in foreign journals of ophthalmology with respect to the number of citations and the quality of reporting [by applying the Consolidated Standards for Reporting Trials (CONSORT) statement writing standards]. The sample of this systematic review comprised the two Brazilian journals of ophthalmology indexed at Science Citation Index Expanded and six of the foreign journals of ophthalmology with highest Impact Factor® according ISI. All clinical trials (CTs) published from January 2009 to December 2010 at the Brazilians journals and a 1:1 randomized sample of the foreign journals were included. The primary outcome was the number of citations through the end of 2011. Subgroup analysis included language. The secondary outcome included likelihood of citation (cited at least once versus no citation), and presence or absence of CONSORT statement indicators. The citation counts were statistically significantly higher (Pjournals of ophthalmology still are low when compared with the foreign journals of ophthalmology with highest Impact Factor®.

  7. Electroencephalography as a diagnostic technique for canine neurological diseases

    Directory of Open Access Journals (Sweden)

    Wrzosek Marcin

    2016-06-01

    Full Text Available Electroencephalography (EEG is a non-invasive examination method for the assessment of functional central nervous system (CNS disturbances. In human medicine it has a special importance as a diagnostic tool for epilepsy. Although many studies were done on the use of EEG for diagnostics of canine central nervous system disorders, the technique is still not applied routinely. The purpose of this paper was to review the use of the electroencephalography in canine neurological disorders of central nervous system diagnosis and assess the future perspectives of this technique in veterinary medicine.

  8. Trends in impact factors of ophthalmology journals.

    Science.gov (United States)

    Vainer, Igor; Mimouni, Francis; Blumenthal, Eytan Z; Mimouni, Michael

    2016-09-01

    To test whether there is an association between the growth in the number of ophthalmic journals in the past years and their mean and maximum impact factor (IF) as a common sign of scientific proliferation. Using data from the 2013 Journal Citation Report database a study of the major clinical medical fields was conducted to assess the correlation between the number of journals and maximum IF in a given field in the year 2013. In the field of ophthalmology, we examined the correlation between year, number of journals, mean IF and maximum IF in the field of ophthalmology throughout the years 2000-2013. In the major medical fields, a positive correlation was found between the number of journals and the maximum IF (quadratic R2 = 0.71, Pjournals and mean IF (R2 = 0.84, Pjournals and maximum IF (R2 = 0.71, Pjournals in the field of ophthalmology. In the future, the formation of additional ophthalmology journals is likely to further increase the IFs of existing journals.

  9. [Advances of Molecular Diagnostic Techniques Application in Clinical Diagnosis.

    Science.gov (United States)

    Ying, Bin-Wu

    2016-11-01

    Over the past 20 years,clinical molecular diagnostic technology has made rapid development,and became the most promising field in clinical laboratory medicine.In particular,with the development of genomics,clinical molecular diagnostic methods will reveal the nature of clinical diseases in a deeper level,thus guiding the clinical diagnosis and treatments.Many molecular diagnostic projects have been routinely applied in clinical works.This paper reviews the advances on application of clinical diagnostic techniques in infectious disease,tumor and genetic disorders,including nucleic acid amplification,biochip,next-generation sequencing,and automation molecular system,and so on.

  10. Nigerian Journal of Ophthalmology

    African Journals Online (AJOL)

    tulyasys

    Nigerian Journal of Ophthalmology / Jan-Jun 2014 / Vol 1 | Issue 1. I. Nigerian Journal of ... Inquiries about advertising should be sent to Medknow. Publications ... reproduce articles/information from this journal, please ... BUSINESS EDITOR.

  11. Technique of infrared synchrotron acceleration diagnostics

    International Nuclear Information System (INIS)

    Mal'tsev, A.A.; Mal'tsev, M.A.

    1997-01-01

    Techniques of measuring of current and geometric parameters and evaluating of energy parameters of the ring bunch of relativistic low-energy electrons have been presented. They have been based on using the synchrotron radiation effect in its infrared spectral part. Fast infrared detectors have provided radiation detection in the spectral range Δλ ≅ 0.3-45 μm. The descriptions of some data monitoring and measuring systems developed in JINR for the realization of techniques of the infrared synchrotron acceleration diagnostics have been given. Infrared optics elements specially developed have been used in these systems

  12. The gamma knife in ophthalmology. Part One--Uveal melanoma.

    Science.gov (United States)

    Wygledowska-Promieńska, Dorota; Jurys, Małgorzata; Wilczyński, Tomasz; Drzyzga, Łukasz

    2014-01-01

    The Gamma Knife was designed by Lars Leksell in the early 1950's. It gave rise to a new discipline of medicine--stereotactic radiosurgery. Primarily dedicated to neurosurgery, the Gamma Knife has become an alternative, widely used surgery technique. According to Elekta's statistics, approximately 60,000 people are treated with Leksell Gamma Knife every year and it is the most extensively studied stereotactic radiosurgery system in the world. The Leksell Gamma Knife can also be used in ophthalmology. The gamma ray beam concentration enables effective treatment of uveal melanoma, choroidal hemangioma, orbital tumors or even choroidal neovascularization. The virtue of Leksell Gamma Knife is its extreme precision, non-invasiveness and the possibility of outpatient treatment, which significantly reduces costs and diminishes post-operative complications. Innovative solutions shorten a single session to a minimum, which is very comfortable and safe for both staff and patients. Advantages and possible side effects of gamma knife radiosurgery are well-documented in the professional literature. The objective of this review is to present the recognized applications of Leksell Gamma Knife in ophthalmology.

  13. Paradigm Shifts in Ophthalmic Diagnostics.

    Science.gov (United States)

    Sebag, J; Sadun, Alfredo A; Pierce, Eric A

    2016-08-01

    Future advances in ophthalmology will see a paradigm shift in diagnostics from a focus on dysfunction and disease to better measures of psychophysical function and health. Practical methods to define genotypes will be increasingly important and non-invasive nanotechnologies are needed to detect molecular changes that predate histopathology. This is not a review nor meant to be comprehensive. Specific topics have been selected to illustrate the principles of important paradigm shifts that will influence the future of ophthalmic diagnostics. It is our impression that future evaluation of vision will go beyond visual acuity to assess ocular health in terms of psychophysical function. The definition of disease will incorporate genotype into what has historically been a phenotype-centric discipline. Non-invasive nanotechnologies will enable a paradigm shift from disease detection on a cellular level to a sub-cellular molecular level. Vision can be evaluated beyond visual acuity by measuring contrast sensitivity, color vision, and macular function, as these provide better insights into the impact of aging and disease. Distortions can be quantified and the psychophysical basis of vision can be better evaluated than in the past by designing tests that assess particular macular cell function(s). Advances in our understanding of the genetic basis of eye diseases will enable better characterization of ocular health and disease. Non-invasive nanotechnologies can assess molecular changes in the lens, vitreous, and macula that predate visible pathology. Oxygen metabolism and circulatory physiology are measurable indices of ocular health that can detect variations of physiology and early disease. This overview of paradigm shifts in ophthalmology suggests that the future will see significant improvements in ophthalmic diagnostics. The selected topics illustrate the principles of these paradigm shifts and should serve as a guide to further research and development. Indeed

  14. Three dimensional imaging technique for laser-plasma diagnostics

    International Nuclear Information System (INIS)

    Jiang Shaoen; Zheng Zhijian; Liu Zhongli

    2001-01-01

    A CT technique for laser-plasma diagnostic and a three-dimensional (3D) image reconstruction program (CT3D) have been developed. The 3D images of the laser-plasma are reconstructed by using a multiplication algebraic reconstruction technique (MART) from five pinhole camera images obtained along different sight directions. The technique has been used to measure the three-dimensional distribution of X-ray of laser-plasma experiments in Xingguang II device, and the good results are obtained. This shows that a CT technique can be applied to ICF experiments

  15. Three dimensional imaging technique for laser-plasma diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Shaoen, Jiang; Zhijian, Zheng; Zhongli, Liu [China Academy of Engineering Physics, Chengdu (China)

    2001-04-01

    A CT technique for laser-plasma diagnostic and a three-dimensional (3D) image reconstruction program (CT3D) have been developed. The 3D images of the laser-plasma are reconstructed by using a multiplication algebraic reconstruction technique (MART) from five pinhole camera images obtained along different sight directions. The technique has been used to measure the three-dimensional distribution of X-ray of laser-plasma experiments in Xingguang II device, and the good results are obtained. This shows that a CT technique can be applied to ICF experiments.

  16. A REVIEW ON DIAGNOSTIC TECHNIQUES FOR BRUCELLOSIS

    African Journals Online (AJOL)

    User

    2014-01-01

    Jan 1, 2014 ... Brucellosis presents with many clinical manifestation that make its diagnosis a difficult task. Ever since the report of the first serologic test for brucellosis, a definitive diagnostic technique has been actively pursued. The most widely used methods of diagnosis are based on serology, which measures the.

  17. [To strengthen the education on basic knowledge and skills of neuro-ophthalmology].

    Science.gov (United States)

    Zhang, Xiao-jun; Wang, Ning-li

    2011-12-01

    Basic knowledge and skills are cornerstone of the diagnosis and treatment of neuro-ophthalmology diseases in ophthalmology practice. Due to the interdisciplinary features of neuro-ophthalmology, neuro-anatomy, neuro-physiology related to eyes, neuro-image and neuro-electrodiagnosis, these should be included in the education for the ophthalmologist. Special attention should be paid to training on capability of logically thinking in neuro-ophthalmology. Multiple ways can be used for the education of ophthalmologists and neurologists for the enhancement of basic knowledge and skills of neuro-ophthalmology in China.

  18. Novel non-intercepting diagnostic techniques for low-emittance relativistic electron beams

    International Nuclear Information System (INIS)

    Moran, M.J.; Chang, B.

    1988-01-01

    Relativistic electron beams are being generated with emittances low enough that diffraction radiation can be used for beam diagnostics. Techniques based on diffraction radiation can be used to measure the beam transverse momentum distribution and to measure the transverse spatial distribution. The radiation is intense and can be in the visible spectral region where optical diagnostic techniques can be used to maximum advantage. 4 refs. 3 figs

  19. The Awareness of Health Professionals in Diagnostic Techniques ...

    African Journals Online (AJOL)

    hanumantp

    clear that most reviewed articles used the same conventional methods in ... Knowledge about the possible correlation of occult blood with reasons other than ... diagnostic techniques used in the examination of intestinal parasites in Gaza Strip.

  20. Lasers in Ophthalmology

    Institute of Scientific and Technical Information of China (English)

    1992-01-01

    In recent years,lasers have entered every fieldof medicine and especially so in ophthalmol-ogy.The scientific basis of lasers in ophthal-mology is based on three mechanisms:1.Photothermal effectLasers:argon,krypton,dye and diodeA thermal effect is generated when laserenergy is absorbed by pigment leading to in-creased vibration and therefore heat content.A

  1. Adaptive techniques for diagnostics of vibrating structures

    International Nuclear Information System (INIS)

    Skormin, V.A.; Sankar, S.

    1983-01-01

    An adaptive diagnostic procedure for vibrating structures based on correspondence between current estimates of stiffness matrix and structure status is proposed. Procedure employs adaptive mathematical description of the vibrating structure in frequency domain, statistical techniques for detection and location of changes of structure properties, 'recognition' and prediction of defects. (orig.)

  2. Prototype Development: Context-Driven Dynamic XML Ophthalmologic Data Capture Application

    Science.gov (United States)

    Schwei, Kelsey M; Kadolph, Christopher; Finamore, Joseph; Cancel, Efrain; McCarty, Catherine A; Okorie, Asha; Thomas, Kate L; Allen Pacheco, Jennifer; Pathak, Jyotishman; Ellis, Stephen B; Denny, Joshua C; Rasmussen, Luke V; Tromp, Gerard; Williams, Marc S; Vrabec, Tamara R; Brilliant, Murray H

    2017-01-01

    Background The capture and integration of structured ophthalmologic data into electronic health records (EHRs) has historically been a challenge. However, the importance of this activity for patient care and research is critical. Objective The purpose of this study was to develop a prototype of a context-driven dynamic extensible markup language (XML) ophthalmologic data capture application for research and clinical care that could be easily integrated into an EHR system. Methods Stakeholders in the medical, research, and informatics fields were interviewed and surveyed to determine data and system requirements for ophthalmologic data capture. On the basis of these requirements, an ophthalmology data capture application was developed to collect and store discrete data elements with important graphical information. Results The context-driven data entry application supports several features, including ink-over drawing capability for documenting eye abnormalities, context-based Web controls that guide data entry based on preestablished dependencies, and an adaptable database or XML schema that stores Web form specifications and allows for immediate changes in form layout or content. The application utilizes Web services to enable data integration with a variety of EHRs for retrieval and storage of patient data. Conclusions This paper describes the development process used to create a context-driven dynamic XML data capture application for optometry and ophthalmology. The list of ophthalmologic data elements identified as important for care and research can be used as a baseline list for future ophthalmologic data collection activities. PMID:28903894

  3. Whole Genome Sequencing Increases Molecular Diagnostic Yield Compared with Current Diagnostic Testing for Inherited Retinal Disease.

    Science.gov (United States)

    Ellingford, Jamie M; Barton, Stephanie; Bhaskar, Sanjeev; Williams, Simon G; Sergouniotis, Panagiotis I; O'Sullivan, James; Lamb, Janine A; Perveen, Rahat; Hall, Georgina; Newman, William G; Bishop, Paul N; Roberts, Stephen A; Leach, Rick; Tearle, Rick; Bayliss, Stuart; Ramsden, Simon C; Nemeth, Andrea H; Black, Graeme C M

    2016-05-01

    To compare the efficacy of whole genome sequencing (WGS) with targeted next-generation sequencing (NGS) in the diagnosis of inherited retinal disease (IRD). Case series. A total of 562 patients diagnosed with IRD. We performed a direct comparative analysis of current molecular diagnostics with WGS. We retrospectively reviewed the findings from a diagnostic NGS DNA test for 562 patients with IRD. A subset of 46 of 562 patients (encompassing potential clinical outcomes of diagnostic analysis) also underwent WGS, and we compared mutation detection rates and molecular diagnostic yields. In addition, we compared the sensitivity and specificity of the 2 techniques to identify known single nucleotide variants (SNVs) using 6 control samples with publically available genotype data. Diagnostic yield of genomic testing. Across known disease-causing genes, targeted NGS and WGS achieved similar levels of sensitivity and specificity for SNV detection. However, WGS also identified 14 clinically relevant genetic variants through WGS that had not been identified by NGS diagnostic testing for the 46 individuals with IRD. These variants included large deletions and variants in noncoding regions of the genome. Identification of these variants confirmed a molecular diagnosis of IRD for 11 of the 33 individuals referred for WGS who had not obtained a molecular diagnosis through targeted NGS testing. Weighted estimates, accounting for population structure, suggest that WGS methods could result in an overall 29% (95% confidence interval, 15-45) uplift in diagnostic yield. We show that WGS methods can detect disease-causing genetic variants missed by current NGS diagnostic methodologies for IRD and thereby demonstrate the clinical utility and additional value of WGS. Copyright © 2016 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  4. Modeling the consumer's perception of experiential marketing in the Romanian private ophthalmologic services.

    Science.gov (United States)

    Gheorghe, Consuela-Mădălina; Gheorghe, Iuliana-Raluca; Purcărea, Victor Lorin

    2017-01-01

    Introduction. The importance of experience in marketing grew, as the concept itself is very personal and difficult to measure. Experience turns out to be complicated but once placed in a context it gets significant features. As the health care competitive environment increases, marketers are looking for new and effective methods of engaging consumers by using experiential marketing strategies. Moreover, little is known about the consumers' perceptions related to ophthalmologic services. Aim. The objective of this paper was to measure the consumer's perception of experiential marketing in the Romanian private ophthalmologic services by using structural equation modeling. Materials and Methods. The Experiential Marketing model consisted of the following components: Sense Experience, Feel Experience, Think Experience, Act Experience and Relate Experience as well as the consequences of applying Experiential Marketing in the form of willingness to purchase a service, generating word-of-mouth communication and building consumer loyalty. The sampling method was non-probabilistic, using the snowball technique and the sample was made up of 190 people who wore eyeglasses for more than 3 years. The instrument for data collection was a self-administered questionnaire, which consisted of 2 parts: the first section contained several demographic questions and the second section encompassed closed end questions related to the perception of private ophthalmologic services from an experiential marketing perspective. All the second section questions were measured on a 5-point Likert scale ranging from 1 with Strongly Disagree to 5 to Strongly Agree. The data analysis was conducted in SPSS and the structural equation modeling was performed in WarpPLS version 6.0. Findings. There were 71.05% respondents, who appreciated the application of experiential marketing in private ophthalmologic services, followed by 18.95%, who were confused. The demographic profile of respondents encompassed

  5. Progress in diagnostic techniques for SC [superconducting] cavities

    International Nuclear Information System (INIS)

    Reece, C.E.

    1988-01-01

    Despite the very real progress that has been made, the routine performance of superconducting cavities still falls far short of both the theoretical expectations and the performance of afew exceptional examples. It is the task of systematically applied diagnostic techniques to reveal additional information concerning the response of superconducting surfaces to applied RF fields. In this paper we will direct our attention to discussions of recent developments in diagnostic techniqeus, such as thermometry in superfluid helium, and scanning laser acoustic microscopy. 18 refs., 12 figs

  6. The radiation protection optimisation in contrast X-ray diagnostic techniques

    International Nuclear Information System (INIS)

    Markovic, S.; Pavlovic, R.

    1995-01-01

    In the class of artificial sources, X-ray diagnostic techniques irradiate global population with more than 90 % share in total dose. At the same time this is the only area with high possibilities in collective dose reduction without important investments. Exposure of the medical team is mainly related to unnecessary irradiation. Eliminating this unnecessary irradiation quality of diagnostic information remains undisturbed. From the radiation protection point of view the most critical X-ray diagnostic method is angiography. This paper presents the radiation protection optimisation calculation of the protective lead thickness using the Cost - Benefit analysis technique. The obtained numerical results are based on calculated collective dose, the estimated prices of the lead and lead glass thickness and the adopted price for monetary value of the collective dose unit α. (author) 3 figs., 10 refs

  7. The radiation protection optimisation in contrast X-ray diagnostic techniques

    Energy Technology Data Exchange (ETDEWEB)

    Markovic, S; Pavlovic, R [Inst. of Nuclear Science Vinca, Belgrade (Yugoslavia). Radiation and Environmental Protection Lab.; Boreli, F [Fac. of Electrical Engineering, Belgrade (Yugoslavia)

    1996-12-31

    In the class of artificial sources, X-ray diagnostic techniques irradiate global population with more than 90 % share in total dose. At the same time this is the only area with high possibilities in collective dose reduction without important investments. Exposure of the medical team is mainly related to unnecessary irradiation. Eliminating this unnecessary irradiation quality of diagnostic information remains undisturbed. From the radiation protection point of view the most critical X-ray diagnostic method is angiography. This paper presents the radiation protection optimisation calculation of the protective lead thickness using the Cost - Benefit analysis technique. The obtained numerical results are based on calculated collective dose, the estimated prices of the lead and lead glass thickness and the adopted price for monetary value of the collective dose unit {alpha}. (author) 3 figs., 10 refs.

  8. Dental diagnostics using optical coherence techniques

    Energy Technology Data Exchange (ETDEWEB)

    Nathel, H. [Lawrence Livermore National Lab., CA (United States); Colston, B. [Univ. of California, San Francisco, CA (United States); Armitage, G. [Univ. of California, Davis, CA (United States)] [and others

    1994-11-15

    Optical radiation can be used for diagnostic purposes in oral medicine. However, due to the turbid, amorphous, and inhomogeneous nature of dental tissue conventional techniques used to transilluminate materials are not well suited to dental tissues. Optical coherence techniques either in the time- of frequency-domain offer the capabilities of discriminating scattered from unscattered light, thus allowing for imaging through turbid tissue. Currently, using optical time-domain reflectometry we are able to discriminate specular from diffuse reflections occurring at tissue boundaries. We have determined the specular reflectivity of enamel and dentin to be approximately 6.6 x 10{sup -5} and 1.3 x 10{sup -6}, respectively. Implications to periodontal imaging will be discussed.

  9. VALUE-BASED MEDICINE AND OPHTHALMOLOGY: AN APPRAISAL OF COST-UTILITY ANALYSES

    Science.gov (United States)

    Brown, Gary C; Brown, Melissa M; Sharma, Sanjay; Brown, Heidi; Smithen, Lindsay; Leeser, David B; Beauchamp, George

    2004-01-01

    ABSTRACT Purpose To ascertain the extent to which ophthalmologic interventions have been evaluated in value-based medicine format. Methods Retrospective literature review. Papers in the healthcare literature utilizing cost-utility analysis were reviewed by researchers at the Center for Value-Based Medicine, Flourtown, Pennsylvania. A literature review of papers addressing the cost-utility analysis of ophthalmologic procedures in the United States over a 12-year period from 1992 to 2003 was undertaken using the National Library of Medicine and EMBASE databases. The cost-utility of ophthalmologic interventions in inflation-adjusted (real) year 2003 US dollars expended per quality-adjusted life-year ($/QALY) was ascertained in all instances. Results A total of 19 papers were found, including a total of 25 interventions. The median cost-utility of ophthalmologic interventions was $5,219/QALY, with a range from $746/QALY to $6.5 million/QALY. Conclusions The majority of ophthalmologic interventions are especially cost-effective by conventional standards. This is because of the substantial value that ophthalmologic interventions confer to patients with eye diseases for the resources expended. PMID:15747756

  10. New diagnostic technique for Zeeman-compensated atomic beam slowing: technique and results

    OpenAIRE

    Molenaar, P.A.; Straten, P. van der; Heideman, H.G.M.; Metcalf, H.

    1997-01-01

    We have developed a new diagnostic tool for the study of Zeeman-compensated slowing of an alkali atomic beam. Our time-of-flight technique measures the longitudinal veloc- ity distribution of the slowed atoms with a resolution below the Doppler limit of 30 cm/s. Furthermore, it can map the position and velocity distribution of atoms in either ground hyperfine level inside the solenoid without any devices inside the solenoid. The technique reveals the optical pumping ef- fects, and shows in de...

  11. New diagnostic technique for Zeeman-compensated atomic beam slowing: technique and results

    NARCIS (Netherlands)

    Molenaar, P.A.; Straten, P. van der; Heideman, H.G.M.; Metcalf, H.

    1997-01-01

    We have developed a new diagnostic tool for the study of Zeeman-compensated slowing of an alkali atomic beam. Our time-of-flight technique measures the longitudinal veloc- ity distribution of the slowed atoms with a resolution below the Doppler limit of 30 cm/s. Furthermore, it can map

  12. Breaking bad news: A communication competency for ophthalmology training programs.

    Science.gov (United States)

    Hilkert, Sarah M; Cebulla, Colleen M; Jain, Shelly Gupta; Pfeil, Sheryl A; Benes, Susan C; Robbins, Shira L

    As the ophthalmology accreditation system undergoes major changes, training programs must evaluate residents in the 6 core competencies, including appropriately communicating bad news. Although the literature is replete with recommendations for breaking bad news across various non-ophthalmology specialties, no formal training programs exist for ophthalmology. There are many valuable lessons to be learned from our colleagues regarding this important skill. We examine the historic basis for breaking bad news, explore current recommendations among other specialties, and then evaluate a pilot study in breaking bad news for ophthalmology residents. The results of this study are limited by a small number of residents at a single academic center. Future studies from multiple training programs should be conducted to further evaluate the need and efficacy of formal communication skills training in this area, as well as the generalizability of our pilot training program. If validated, this work could serve as a template for future ophthalmology resident training and evaluation in this core competency. Copyright © 2016 Elsevier Inc. All rights reserved.

  13. Teaching of ophthalmology in undergraduate curricula: a survey of Australasian and Asian medical schools.

    Science.gov (United States)

    Fan, Jennifer C; Sherwin, Trevor; McGhee, Charles N J

    2007-01-01

    Despite established international guidelines on preferred teaching components for ophthalmology in undergraduate curricula, with increasingly less specialty-based undergraduate teaching within curricula, teaching of core ophthalmology knowledge and skills may become marginalized. This survey aims to evaluate the current state of undergraduate ophthalmology teaching in Australasia and proximate Asian medical schools. A questionnaire was developed to determine the content and extent of ophthalmology teaching in the undergraduate medical curriculum. The questionnaire was sent to 25 medical schools throughout Australasia and Asia. Nineteen of the 25 questionnaires were returned (76% response rate). Ophthalmology teaching programmes ranged from 2 to 20 days: five (26%) medical schools having one ophthalmology attachment; six schools (32%) two attachments; and the remainder three or more. Only seven of the schools taught all 13 ophthalmology topics recommended in current curriculum guidelines. Ocular examination (100%), lens and cataract (95%) and ocular manifestations of systemic disease (95%) were the most commonly taught topics, with intraocular tumours only covered by 10 schools (53%). Students in 14 schools (74%) attended ophthalmology operating theatre, but only two schools (11%) offered attendance at optometry clinics. Ten schools (53%) required a pass in ophthalmology to complete the academic year. Ophthalmology may increasingly be a small, or even absent, component of undergraduate medical curricula. Despite established international ophthalmology curriculum guidelines, this survey highlights significant lack of uniformity in their implementation.

  14. A Hybrid Neural Network-Genetic Algorithm Technique for Aircraft Engine Performance Diagnostics

    Science.gov (United States)

    Kobayashi, Takahisa; Simon, Donald L.

    2001-01-01

    In this paper, a model-based diagnostic method, which utilizes Neural Networks and Genetic Algorithms, is investigated. Neural networks are applied to estimate the engine internal health, and Genetic Algorithms are applied for sensor bias detection and estimation. This hybrid approach takes advantage of the nonlinear estimation capability provided by neural networks while improving the robustness to measurement uncertainty through the application of Genetic Algorithms. The hybrid diagnostic technique also has the ability to rank multiple potential solutions for a given set of anomalous sensor measurements in order to reduce false alarms and missed detections. The performance of the hybrid diagnostic technique is evaluated through some case studies derived from a turbofan engine simulation. The results show this approach is promising for reliable diagnostics of aircraft engines.

  15. [Establishment of diagnosis and treatment patterns of holistic integrated medicine for neuro-ophthalmology].

    Science.gov (United States)

    Wang, Yanling

    2014-12-01

    Neuro-ophthalmology, as an interdisciplinary, covers at least three disciplines- ophthalmology, neurology and neurosurgery. With limited knowledge in each discipline, doctors often make misdiagnoses for neuro-ophthalmology diseases. Therefore, it is imperative to abandon the distinction between disciplines and combine all the knowledge to diagnose and treat patients in patterns of holistic integrated medicine in order to effectively improve the diagnosis and treatment of neuro-ophthalmology.

  16. Evaluation of techniques for inspection and diagnostics of HWR pressure tubes

    International Nuclear Information System (INIS)

    Choi, Jong-Ho

    2008-01-01

    Efficient and accurate inspection and diagnostic techniques for various reactor components and systems, especially pressure tubes for Heavy Water Reactors (HWRs), are an important factor in assuring reliable and safe plant operation. To foster international collaboration in the efficient and safe use of nuclear power, the IAEA conducted a Coordinated Research Project (CRP) on Inter-comparison of Techniques for HWR Pressure Tube Inspection and Diagnostics. The objective of the CRP was to inter-compare inspection and diagnostic techniques, in use and being developed, for structural integrity assessment of HWR pressure tubes. During the first phase of the CRP, participants investigated the capability of different techniques to detect and characterize flaws. During the second phase, participants collaborated to determine the hydrogen concentration and to detect and characterize hydride blisters in zirconium alloy pressure tubes. Eight organizations from six countries, which operate HWRs, have participated in this CRP, Most of the techniques examined are well established and many of them are regularly used during in-service inspection of pressure tubes. The inter-comparison of these techniques provides a platform for identifying a particular technique (or a set of techniques), which is more accurate and reliable as compared to others for a specified task. The CRP also witnessed some new methodologies, which can be implemented on in-service inspection tools. These new techniques could complement the existing ones to overcome their limitations, thereby improving the reliability and accuracy of in-service inspection. This CRP also identified future areas of research and development. (author)

  17. Modeling the consumer’s perception of experiential marketing in the Romanian private ophthalmologic services

    Science.gov (United States)

    Gheorghe, Consuela-Mădălina; Gheorghe, Iuliana-Raluca; Purcărea, Victor Lorin

    2017-01-01

    Introduction. The importance of experience in marketing grew, as the concept itself is very personal and difficult to measure. Experience turns out to be complicated but once placed in a context it gets significant features. As the health care competitive environment increases, marketers are looking for new and effective methods of engaging consumers by using experiential marketing strategies. Moreover, little is known about the consumers’ perceptions related to ophthalmologic services. Aim. The objective of this paper was to measure the consumer’s perception of experiential marketing in the Romanian private ophthalmologic services by using structural equation modeling. Materials and Methods. The Experiential Marketing model consisted of the following components: Sense Experience, Feel Experience, Think Experience, Act Experience and Relate Experience as well as the consequences of applying Experiential Marketing in the form of willingness to purchase a service, generating word-of-mouth communication and building consumer loyalty. The sampling method was non-probabilistic, using the snowball technique and the sample was made up of 190 people who wore eyeglasses for more than 3 years. The instrument for data collection was a self-administered questionnaire, which consisted of 2 parts: the first section contained several demographic questions and the second section encompassed closed end questions related to the perception of private ophthalmologic services from an experiential marketing perspective. All the second section questions were measured on a 5-point Likert scale ranging from 1 with Strongly Disagree to 5 to Strongly Agree. The data analysis was conducted in SPSS and the structural equation modeling was performed in WarpPLS version 6.0. Findings. There were 71.05% respondents, who appreciated the application of experiential marketing in private ophthalmologic services, followed by 18.95%, who were confused. The demographic profile of respondents

  18. Prototype Development: Context-Driven Dynamic XML Ophthalmologic Data Capture Application.

    Science.gov (United States)

    Peissig, Peggy; Schwei, Kelsey M; Kadolph, Christopher; Finamore, Joseph; Cancel, Efrain; McCarty, Catherine A; Okorie, Asha; Thomas, Kate L; Allen Pacheco, Jennifer; Pathak, Jyotishman; Ellis, Stephen B; Denny, Joshua C; Rasmussen, Luke V; Tromp, Gerard; Williams, Marc S; Vrabec, Tamara R; Brilliant, Murray H

    2017-09-13

    The capture and integration of structured ophthalmologic data into electronic health records (EHRs) has historically been a challenge. However, the importance of this activity for patient care and research is critical. The purpose of this study was to develop a prototype of a context-driven dynamic extensible markup language (XML) ophthalmologic data capture application for research and clinical care that could be easily integrated into an EHR system. Stakeholders in the medical, research, and informatics fields were interviewed and surveyed to determine data and system requirements for ophthalmologic data capture. On the basis of these requirements, an ophthalmology data capture application was developed to collect and store discrete data elements with important graphical information. The context-driven data entry application supports several features, including ink-over drawing capability for documenting eye abnormalities, context-based Web controls that guide data entry based on preestablished dependencies, and an adaptable database or XML schema that stores Web form specifications and allows for immediate changes in form layout or content. The application utilizes Web services to enable data integration with a variety of EHRs for retrieval and storage of patient data. This paper describes the development process used to create a context-driven dynamic XML data capture application for optometry and ophthalmology. The list of ophthalmologic data elements identified as important for care and research can be used as a baseline list for future ophthalmologic data collection activities. ©Peggy Peissig, Kelsey M Schwei, Christopher Kadolph, Joseph Finamore, Efrain Cancel, Catherine A McCarty, Asha Okorie, Kate L Thomas, Jennifer Allen Pacheco, Jyotishman Pathak, Stephen B Ellis, Joshua C Denny, Luke V Rasmussen, Gerard Tromp, Marc S Williams, Tamara R Vrabec, Murray H Brilliant. Originally published in JMIR Medical Informatics (http://medinform.jmir.org), 13.09.2017.

  19. Reliability of diagnostic imaging techniques in suspected acute appendicitis: proposed diagnostic protocol

    International Nuclear Information System (INIS)

    Cura del, J. L.; Oleaga, L.; Grande, D.; Vela, A. C.; Ibanez, A. M.

    2001-01-01

    To study the utility of ultrasound and computed tomography (CT) in case of suspected appendicitis. To determine the diagnostic yield in terms of different clinical contexts and patient characteristics. to assess the costs and benefits of introducing these techniques and propose a protocol for their use. Negative appendectomies, complications and length of hospital stay in a group of 152 patients with suspected appendicitis who underwent ultrasound and CT were compared with those of 180 patients who underwent appendectomy during the same time period, but had not been selected for the first group: these patients costs for each group were calculated. In the first group, the diagnostic value of the clinical signs was also evaluated. The reliability of the clinical signs was limited, while the results with ultrasound and CT were excellent. The incidence of negative appendectomy was 9.6% in the study group and 12.2% in the control group. Moreover, there were fewer complications and a shorter hospital stay in the first group. Among men, however, the rate of negative appendectomy was lower in the control group. The cost of using ultrasound and CT in the management of appendicitis was only slightly higher than that of the control group. Although ultrasound and CT are not necessary in cases in which the probability of appendicitis is low or in men presenting clear clinical evidence, the use of these techniques is indicated in the remaining cases in which appendicitis is suspected. In children, ultrasound is the technique of choice. In all other patients, if negative results are obtained with one of the two techniques, the other should be performed. (Author) 49 refs

  20. Scientometric analysis of published papers in global ophthalmology in the past ten years.

    Science.gov (United States)

    Yu, Zheng-Lu; Hu, Xin-Yue; Wang, Ying-Na; Ma, Zheng

    2017-01-01

    To investigate the published papers of ophthalmology in past ten years and explore the development of ophthalmology. The data of this study retrieved from Science Citation Index Expanded and downloaded online in November 2017, including all the papers with publication year from 2007-2016 were analyzed. The papers were based on the Web of Science category and the journals were based on the Journal Citation Report category. The number of ophthalmology papers increased from 7450 to 9089 during 2007 to 2017. The average rate increased 2.2% annually. USA accounts for one thirds of the total and two thirds of the highly cited papers. In Asia, China, Japan and South Korea were in Top 10 by the number of ophthalmology papers. UK, Germany, Japan and Australia also had great impact in global ophthalmology. The hot spots included endothelial growth factor, optical coherence tomography and open-angle glaucoma. USA is in the leading position in global ophthalmology. Part of Asian countries play an important role in the development of ophthalmology, but the impact needs to be improved.

  1. Neuro-ophthalmological manifestations of neurosyphilis in 22 cases

    Directory of Open Access Journals (Sweden)

    Xiao-Juan Fan

    2017-10-01

    Full Text Available AIM: To analyze the characteristics of neurological ophthalmology manifestation of patients with neurosyphilis.METHODS: Retrospective and nonrandomized case analysis were used. Totally 22 cases of 39 eyes were included. They were 17 males and 5 females, aged from 34 to 65 years old. The average age were 49.6 years old. RESULTS: The optic nerve atrophy presented in 11 cases of 22 eyes. One eye of them accompanied by left eye oculomotor nerve palsy; 5 eyes in 3 cases expressed as optic neuritis acute phase; neuroretinitis appeared in 4 cases of 6 eyes; 1 case of 2 eyes expressed as chorioretinitis accompanied by optic disc edema; central retinal artery occlusion were found in 1 case of 1 eye. Argyll-Robertson pupil was as only manifestation in 2 cases of 3 eyes. In all cases, Argyll-Robertson pupil signs can be seen in 19 eyes. Treponema pallidum particle agglutination test(TPPAwere positive in all 22 cases. Syphilis rapid plasma reactin test(RPRwere positive in 19 of 21 cases. All patients underwent lumbar puncture and cerebrospinal fluid were detected for RPR, cerebrospinal fluid protein, white blood cell count. Cerebrospinal fluid RPR were positive in 13 cases. Cerebrospinal fluid protein were greater than 450mg/L in 18 cases. Cerebrospinal fluid white blood cell count were greater than 5/mm3 in 13 cases. CONCLUSION: Neurosyphilis involving neuro-ophthalmology often occurs in middle-aged men and subacute onset. Both eyes can suffered from optic nerve disease simultaneously or sequencely. A few can be expressed as other cranial nerve palsy, which may lead to misdiagnosis. Considering medical history, clinical manifestations, ophthalmic examination, serum and cerebrospinal fluid laboratory tests can improve the diagnostic rate.

  2. [Organizational ethics: a study in ophthalmologic clinics].

    Science.gov (United States)

    Sanches, Maria Aparecida; Scarpi, Marinho Jorge

    2005-01-01

    Research on the field of organizational ethics to investigate to which extent ophthalmologic clinics, inserted in the competitive atmosphere, in the condition of organizations in search of survival, subordinate ethics to competitiveness in the managerial praxis, that is, in the administrative sphere. Kohlberg is taken as theoretical reference, approaching the theme of ethical subordination to competitiveness. The instrument to evaluate moral behaviors of organizations, elaborated by Licht, is applied. The quantitative method is used, adopting analytic instruments, such as Q of Yule and non parametric tests, when dealing with the data of 41 ophthalmologic clinics. The results of the research seem to indicate that administrators of ophthalmologic clinics of greater performance subordinate ethical principles to competitiveness, seeking to assure the survival of the company and, when confronted with the instrument to evaluate their moral behavior, proposed by Kohlberg, have a significantly smaller presence in the postconventional stage than administrators of ophthalmologic clinics with a smaller performance. One may affirm, according to non parametric tests, at the level of significance of 0.05, that the levels of moral development of the two groups differ significantly. The obtained results are according to the literature, especially concerning the "paradox of the ethical subordination and competitiveness". They also suggest that the warrant of the survival of the company tends to reduce the perception of the groups in power regarding the problems that happen in the community, and that a reduction of the ethical values subordinated to competition occurs, and such reduction provokes growing feelings of economical disputes in the social sphere.

  3. Ophthalmologic Findings in Patients with Neuro-metabolic Disorders.

    Science.gov (United States)

    Jafari, Narjes; Golnik, Karl; Shahriari, Mansoor; Karimzadeh, Parvaneh; Jabbehdari, Sayena

    2018-01-01

    We aimed to present the ophthalmic manifestations of neuro-metabolic disorders. Patients who were diagnosed with neuro-metabolic disorders in the Neurology Department of Mofid Pediatric Hospital in Tehran, Iran, between 2004 and 2014 were included in this study. Disorders were confirmed using clinical findings, neuroimaging, laboratory data, and genomic analyses. All enrolled patients were assessed for ophthalmological abnormalities. A total of 213 patients with 34 different neuro-metabolic disorders were included. Ophthalmological abnormalities were observed in 33.5% of patients. Abnormal findings in the anterior segment included Kayser-Fleischer rings, congenital or secondary cataracts, and lens dislocation into the anterior chamber. Posterior segment (i.e., retina, vitreous body, and optic nerve) evaluation revealed retinitis pigmentosa, cherry-red spots, and optic atrophy. In addition, strabismus, nystagmus, and lack of fixation were noted during external examination. Ophthalmological examination and assessment is essential in patients that may exhibit neuro-metabolic disorders.

  4. Improvement of Railroad Roller Bearing Test Procedures & Development of Roller Bearing Diagnostic Techniques. Volume 2.

    Science.gov (United States)

    1982-04-01

    A comprehensive review of existing basic diagnostic techniques applicable to the railcar roller bearing defect and failure problem was made. Of the potentially feasible diagnostic techniques identified, high frequency vibration was selected for exper...

  5. LEAN SIX SIGMA TECHNIQUES TO IMPROVE OPHTHALMOLOGY CLINIC EFFICIENCY.

    Science.gov (United States)

    Ciulla, Thomas A; Tatikonda, Mohan V; ElMaraghi, Yehya A; Hussain, Rehan M; Hill, Amanda L; Clary, Julie M; Hattab, Eyas

    2017-07-18

    Ophthalmologists serve an increasing volume of a growing elderly population undergoing increasingly complex outpatient medical care, including extensive diagnostic testing and treatment. The resulting prolonged patient visit times ("patient flow times") limit quality, patient and employee satisfaction, and represent waste. Lean Six Sigma process improvement was used in a vitreoretinal practice to decrease patient flow time, demonstrating that this approach can yield significant improvement in health care. Process flow maps were created to determine the most common care pathways within clinic. Three months' visits from the electronic medical record system, which tracks patient task times at each process step in the office were collected. Care tasks and care pathways consuming the greatest time and variation were identified and modified. Follow-up analysis from 6 weeks' visits was conducted to assess improvement. Nearly all patients took one of five paths through the office. Patient flow was redesigned to reduce waiting room time by having staff members immediately start patients into one of those five paths; staffing was adjusted to address high demand tasks, and scheduling was optimized around derived predictors of patient flow times. Follow-up analysis revealed a statistically significant decline in mean patient flow time by 18% and inpatient flow time SD by 4.6%. Patient and employee satisfaction scores improved. Manufacturing industry techniques, such as Lean and Six Sigma, can be used to improve patient care, minimize waste, and enhance patient and staff satisfaction in outpatient clinics.

  6. Textbook of focusing techniques in diagnostic radiography. 5. new rev. ed.

    International Nuclear Information System (INIS)

    Bosnjakovic-Buescher, S.; Riegler-Bubeck, C.; Zimmer-Brossy, M.; Bast, B.

    1998-01-01

    This 5th edition of the standard work on focusing techniques in diagnostic radiography is a guide for X-ray medical technicians and radiologists wishing to optimize their skills and produce images of high technical standard and diagnostic value. The major part of the textbook deals with the focusing and imaging techniques for evaluation of the skeleton and inner body organs. The new edition includes the current legal provisions for radiological protection and the latest quality assurance legislation. It is an indispensable source of reference for clinical departments, radiographic practice, and training institutions. (orig./CB) [de

  7. The invention of gonioscopy by Alexios Trantas and his contribution to ophthalmology.

    Science.gov (United States)

    Kalantzis, G; Georgalas, I; Tsiamis, C; El-Hindy, N; Poulakou-Rebelakou, E

    2015-01-01

    Gonioscopy is a technique used to examine structures in the anterior chamber angle (the fluid filled space inside the eye between the iris and the innermost layer of the cornea, the endothelium). It is an essential tool in ophthalmic practice, particularly in the diagnosis of glaucoma. In 1899, the Greek ophthalmologist Alexios Trantas was the first to visualise the angle in vivo and coined the term 'gonioscopy'. He made a number of other important contributions to ophthalmology.

  8. Literature systematic review on the ophthalmological side effects of interferons

    Directory of Open Access Journals (Sweden)

    Yara Dadalti Fragoso

    2011-08-01

    Full Text Available Interferons alpha and beta have been used worldwide for a few decades, altering the natural history of several severe diseases including hepatitis C, cancer and immune-mediated conditions such as multiple sclerosis. The adverse events profile of interferons is well established, but only isolated reports of ophthalmological complications of interferon therapy have been published. The objective of this study was to carry out a literature systematic review on the subject, bringing to light the need for careful ophthalmological monitoring of patients undergoing interferon treatment. Nearly 500 cases of ophthalmological complications related to interferon have been reported. The most frequent findings were soft exudates, hemorrhages and retina ischemia.

  9. A clinicopathological study of various oral cancer diagnostic techniques

    Directory of Open Access Journals (Sweden)

    G Ulaganathan

    2017-01-01

    Full Text Available Oral cancer is one of the most commonly occurring malignant tumors in the head and neck regions with high incident rate and mortality rate in the developed countries than in the developing countries. Generally, the survival rate of cancer patients may increase when diagnosed at early stage, followed by prompt treatment and therapy. Recently, cancer diagnosis and therapy design for a specific cancer patient have been performed with the advanced computer-aided techniques. The responses of the cancer therapy could be continuously monitored to ensure the effectiveness of the treatment process that hardly requires diagnostic result as quick as possible to improve the quality and patient care. This paper gives an overview of oral cancer occurrence, different types, and various diagnostic techniques. In addition, a brief introduction is given to various stages of immunoanalysis including tissue image preparation, whole slide imaging, and microscopic image analysis.

  10. Teaching and Assessing Systems-based Competency in Ophthalmology Residency Training Programs

    NARCIS (Netherlands)

    Lee, Andrew G.; Beaver, Hilary A.; Greenlee, Emily; Oetting, Thomas A.; Boldt, H. Culver; Olson, Richard; Abramoff, Michael; Carter, Keith

    2007-01-01

    The Accreditation Council for Graduate Medical Education (ACGME) has mandated that residency programs, including ophthalmology, teach and assess specific competencies, including systems-based learning. We review the pertinent literature on systems-based learning for ophthalmology and recommend

  11. Ophthalmology resident surgical competency: a national survey.

    Science.gov (United States)

    Binenbaum, Gil; Volpe, Nicholas J

    2006-07-01

    To describe the prevalence, management, and career outcomes of ophthalmology residents who struggle with surgical competency and to explore related educational issues. Fourteen-question written survey. Fifty-eight program directors at Accreditation Council on Graduate Medical Education-accredited, United States ophthalmology residency programs, representing a total of 2179 resident graduates, between 1991 and 2000. Study participants completed a mailed, anonymous survey whose format combined multiple choice and free comment questions. Number of surgically challenged residents, types of problems identified, types of remediation, final departmental decision at the end of residency, known career outcomes, and residency program use of microsurgical skills laboratories and applicant screening tests. One hundred ninety-nine residents (9% overall; 10% mean per program) were labeled as having trouble mastering surgical skills. All of the programs except 2 had encountered such residents. The most frequently cited problems were poor hand-eye coordination (24%) and poor intraoperative judgment (22%). Most programs were supportive and used educational rather than punitive measures, the most common being extra practice-laboratory time (32%), scheduling cases with the best teaching surgeon (23%), and counseling (21%). Nearly one third (31%) of residents were believed to have overcome their difficulties before graduation. Other residents were encouraged to pursue medical ophthalmology (22%) or to obtain further surgical training through a fellowship (21%) or a supervised practice setting (12%); these residents were granted a departmental statement of satisfactory completion of residency for Board eligibility. Twelve percent were asked to leave residency. Of reported career outcomes, 92% of residents were practicing ophthalmology, 65% as surgical and 27% as medical ophthalmologists. Ninety-eight percent of residency programs had microsurgical practice facilities, 64% had a formal

  12. The human resource crisis in neuro-ophthalmology.

    Science.gov (United States)

    Frohman, Larry P

    2008-09-01

    Neuro-ophthalmology is facing a serious human resource issue. Few are entering the subspecialty, which is perceived as being poorly compensated compared with other subspecialties of ophthalmology. The low compensation comes from the fact that 1) non-procedural encounters remain undervalued, 2) efforts that benefit other medical specialists are not counted, and 3) the relatively low expenses of neuro-ophthalmologists are not factored into compensation formulas. Mission-based budgeting, which forces academic departments to be financially accountable without the expectation of fiscal relief from medical schools or practice plans, has exacerbated the compensation issue. Solutions must come from within neuro-ophthalmology, academic departments, medical schools, and medical practice plans. They include 1) providing educational resources so that neuro-ophthalmologists need not spend so much time teaching the basics, 2) factoring into compensation the impact of neuro-ophthalmologists in teaching and on revenue generation by procedure-based specialists, 3) improving the efficiency of neuro-ophthalmologists in their consultative practices by providing ample clerical support and other measures, 4) providing contractual salary compensation by departments such as neurosurgery to recognize the contributions made by neuro-ophthalmologists, and 5) reorganizing the academic clinical effort as multidisciplinary rather than departmental.

  13. Relocation consequences on an ophthalmology consultation service from an inpatient to outpatient facility

    Directory of Open Access Journals (Sweden)

    Singh JS

    2015-10-01

    Full Text Available Jorawer S Singh,1 Vincent M Imbrogno,2 Mary K Howard,3 Amandip S Cheema,3 Ausra D Selvadurai,4 Surbhi Bansal5 1Department of Ophthalmology, George Washington University, Washington, DC, 2Contemporary Ophthalmology of Erie, Erie, PA, 3Department of Ophthalmology, University at Buffalo, Buffalo, NY, 4OcuSight Eye Care Center, Rochester, NY, 5Department of Ophthalmology, Virginia Commonwealth University, Richmond, VA, USA Importance: This study shows that relocation of an academic ophthalmology residency program from an inpatient to an outpatient setting in western New York does not affect the consult volume but affects management patterns and follow-up rates.Objective: To investigate the effects on the ophthalmology consultation service of an academic program with relocation from a Regional Level-1 Trauma center to an outpatient facility.Design: Consultation notes from 3 years before and 3 years after the University at Buffalo’s (UB Department of Ophthalmology relocation from a Regional Level-1 Trauma center (Erie County Medical Center to an outpatient facility (Ross Eye Institute were obtained from hospital electronic medical records and analyzed.Setting: Hospitalized care and institutional practice.Participants: All inpatient or Emergency Room Ophthalmology consultation patients from the Department of Ophthalmology at UB from 2004 to 2010 (1,379 patients.Exposures: None, this was a retrospective chart review.Main outcome measures: Patient demographics, reason for consult, diagnoses, and ophthalmic procedures performed by the UB Department of Ophthalmology before and after its relocation.Results: Relocation to the outpatient facility did not affect consult volume (P=0.15. The number of consults focusing on ophthalmic conditions, as a percentage of the yearly total, rose 460% (P=0.0001, while systemic condition consults with ocular manifestations fell 83% (P=0.0001. Consults for ocular trauma decreased 65% (P=0.0034. Consults ending with a

  14. Ophthalmology on social networking sites: an observational study of Facebook, Twitter, and LinkedIn

    Directory of Open Access Journals (Sweden)

    Micieli JA

    2015-02-01

    Full Text Available Jonathan A Micieli,1 Edmund Tsui2 1Department of Ophthalmology and Vision Sciences, University of Toronto, Toronto, ON, Canada; 2Department of Surgery, Dartmouth-Hitchcock Medical Center, Lebanon, NH, USA Background: The use of social media in ophthalmology remains largely unknown. Our aim was to evaluate the extent and involvement of ophthalmology journals, professional associations, trade publications, and patient advocacy and fundraising groups on social networking sites. Methods: An archived list of 107 ophthalmology journals from SCImago, trade publications, professional ophthalmology associations, and patient advocacy organizations were searched for their presence on Facebook, Twitter, and LinkedIn. Activity and popularity of each account was quantified by using the number of “likes” on Facebook, the number of followers on Twitter, and members on LinkedIn. Results: Of the 107 journals ranked by SCImago, 21.5% were present on Facebook and 18.7% were present on Twitter. Journal of Community Eye Health was the most popular on Facebook and JAMA Ophthalmology was most popular on Twitter. Among the 133 members of the International Council of Ophthalmology, 17.3% were present on Facebook, 12.8% were present on Twitter, and 7.5% were present on LinkedIn. The most popular on Facebook was the International Council of Ophthalmology, and the American Academy of Ophthalmology was most popular on Twitter and LinkedIn. Patient advocacy organizations were more popular on all sites compared with journals, professional association, and trade publications. Among the top ten most popular pages in each category, patient advocacy groups were most active followed by trade publications, professional associations, and journals. Conclusion: Patient advocacy groups lead the way in social networking followed by professional organizations and journals. Although some journals use social media, most have yet to engage its full potential and maximize the number of

  15. Analysis of ophthalmological and vision-related publications in Latin America

    Directory of Open Access Journals (Sweden)

    Lesly Carrillo Galván

    Full Text Available ABSTRACT Purpose: To assess scientific production related to ophthalmology and vision in Latin America during the period from 2006 to 2015. Methods: The PubMed, Lilacs (Bireme, Google Scholar, SciELO, and Medigraphic databases were evaluated for this retrospective, descriptive, and comparative study. Results: A total of 1,510 articles was identified. Brazil was the leader in quantitative production in ophthalmology, averaging 85.4 articles per year. Mexico was in second place with 27.4, and Argentina was in third place with 11.1 articles per year. Forty-one percent of articles were published in English, 28.1% dealt with the subspecialty of the retina, and 63% were published by researchers affiliated with universities. The frequency of male first authors was 58.9%, and the journal Arquivos Brasileiros de Oftalmologia accounted for 36.42% of the identified articles. Conclusions: Brazil stands in first place in Latin America in ophthalmologic scientific production. Nearly half of the researchers in ophthalmology in Latin America included in our study were listed in databases other than PubMed.

  16. Medical students perception of undergraduate ophthalmology training in Nnamdi Azikiwe University Nnewi Campus.

    Science.gov (United States)

    Onyekwe, L O; Nwosu, S N N

    2006-12-01

    To determine the perception and aspiration of medical students towards ophthalmology. Information for the study was obtained through forced-choice questionnaire set to 102 medical students in 2000/2001 graduating class in Nnamdi Azikiwe University. One hundred questionnaires were completed. As a specialty of choice ophthalmology ranked fourth {16.0%} as a first choice; second {21.0%} as a second choice and first {26.0%} as a third choice. Ninety-five of respondents found ophthalmology training useful. This cohort of medical students considered ophthalmic training in this institution essential and adequate. Undergraduate ophthalmic course should ensure an understanding of the basic principles of ophthalmology and should be designed to motivate the interest and confidence of the medical students in the specialty. Training period should be at least 4 weeks. With appropriate training ophthalmology can attract reasonable interest as a choice for specification.

  17. The Role of Retinal Imaging and Portable Screening Devices in Tele-ophthalmology Applications for Diabetic Retinopathy Management.

    Science.gov (United States)

    DeBuc, Delia Cabrera

    2016-12-01

    In the years since its introduction, retinal imaging has transformed our capability to visualize the posterior pole of the eye. Increasing practical advances in mobile technology, regular monitoring, and population screening for diabetic retinopathy management offer the opportunity for further development of cost-effective applications through remote assessment of the diabetic eye using portable retinal cameras, smart-phone-based devices and telemedicine networks. Numerous retinal imaging methods and mobile technologies in tele-ophthalmology applications have been reported for diabetic retinopathy screening and management. They provide several advantages of automation, sensitivity, specificity, portability, and miniaturization for the development of point-of-care diagnostics for eye complications in diabetes. The aim of this paper is to review the role of retinal imaging and mobile technologies in tele-ophthalmology applications for diabetic retinopathy screening and management. At large, although improvements in current technology and telemedicine services are still needed, telemedicine has demonstrated to be a worthy tool to support health caregivers in the effective management and prevention of diabetes and its complications.

  18. Finlay y la oftalmología Finlay and ophthalmology

    Directory of Open Access Journals (Sweden)

    Elsa Lisset Arredondo Torres

    2012-04-01

    Full Text Available Se realizó una revisión bibliográfica acerca de la personalidad y la obra del científico camagüeyano Carlos Juan Finlay Barré, para ampliar y profundizar los conocimientos de médicos generales y oftalmólogos. En síntesis, se describe la vida de quien realizó trascendentales contribuciones a la medicina universal. Como sus descubrimientos sobre la fiebre amarilla irradian un conocimiento científico tan elevado, es necesario escudriñar sus aportes a la oftalmología. Se destacan algunos de los aportes más relevantes y de forma precisa se hace referencia a varios estudios realizados por él, así como la descripción de su técnica para la cirugía de catarata.A bibliographical revision on Carlos Juan Finlay Barré’s life and work was carried out to widen and deepen knowledge on general medicine and ophthalmology. In short, the life of man who made significant contributions to universal medicine is herein described. As his discoveries about the yellow fever have provided prominent scientific knowledge, so it is necessary to examine his contributions to ophthalmology. Some of his more relevant contributions and studies are also pointed out, as well as the description of his technique for cataract surgery.

  19. Introduction to metabolomics and its applications in ophthalmology

    Science.gov (United States)

    Tan, S Z; Begley, P; Mullard, G; Hollywood, K A; Bishop, P N

    2016-01-01

    Metabolomics is the study of endogenous and exogenous metabolites in biological systems, which aims to provide comparative semi-quantitative information about all metabolites in the system. Metabolomics is an emerging and potentially powerful tool in ophthalmology research. It is therefore important for health professionals and researchers involved in the speciality to understand the basic principles of metabolomics experiments. This article provides an overview of the experimental workflow and examples of its use in ophthalmology research from the study of disease metabolism and pathogenesis to identification of biomarkers. PMID:26987591

  20. [THE CYTOMETRIC TECHNIQUE OF BINDING OF EOSIN-5-MALEIMIDE IN DIAGNOSTIC OF INHERENT SPHEROCYTOSIS].

    Science.gov (United States)

    Kuzminova, J A; Plyasunova, S A; Jogov, V V; Smetanina, N S

    2016-03-01

    The laboratory diagnostic of inherent spherocytosis is based on detection of spherocytes in peripheral blood, decreasing of index of sphericity, decreasing of osmotic resistance of erythrocytes. The new test of diagnostic of hereditary spherocytosis build on molecular defect was developed on the basis of binding extracellular fragments of protein of band 3 with eosin-5-maleimide (EMA-test). The study was carried out to implement comparative analysis of sensitivity and specificity of techniques applied to diagnose inherent spherocytosis. The sampling of 94 patients with various forms of anemias was analyzed All patients were applied complex clinical laboratory examination including analysis of osmotic resistance of erythrocytes, erythrocytometry and EMA-test as specific techniques of diagnostic of inherent spherocytosis. In 51 out of 94 patients (54%) decreasing of values of EMA-test was detected and in 47 patients diagnosis of inherent spherocytosis was confirmed. The standard values of EMA-test were established in 43 patients (46%) and 12 patients out of them with established diagnosis of inherent spherocytosis. Therefore, sensitivity of EMA-test made up to 79% and specificity - 80%. The most sensitive techniques of diagnostic remain osmotic resistance of erythrocytes (91%) and index of sphericity (up to 96%). But the highest specificity in this respect has EMA-test (80%). Nowadays, none of implemented techniques of diagnostic of inherent spherocytosis can be applied as a universal one. The implementation of complex examination is needed for proper diagnostic of disease.

  1. Case-based reasoning diagnostic technique based on multi-attribute similarity

    Energy Technology Data Exchange (ETDEWEB)

    Makoto, Takahashi [Tohoku University, Miyagi (Japan); Akio, Gofuku [Okayama University, Okayamaa (Japan)

    2014-08-15

    Case-based diagnostic technique has been developed based on the multi-attribute similarity. Specific feature of the developed system is to use multiple attributes of process signals for similarity evaluation to retrieve a similar case stored in a case base. The present technique has been applied to the measurement data from Monju with some simulated anomalies. The results of numerical experiments showed that the present technique can be utilizes as one of the methods for a hybrid-type diagnosis system.

  2. Simplified diagnostic coding sheet for computerized data storage and analysis in ophthalmology.

    Science.gov (United States)

    Tauber, J; Lahav, M

    1987-11-01

    A review of currently-available diagnostic coding systems revealed that most are either too abbreviated or too detailed. We have compiled a simplified diagnostic coding sheet based on the International Coding and Diagnosis (ICD-9), which is both complete and easy to use in a general practice. The information is transferred to a computer, which uses the relevant (ICD-9) diagnoses as database and can be retrieved later for display of patients' problems or analysis of clinical data.

  3. RESULTS OF THE SURVEY CONDUCTED AMONG OPHTHALMOLOGISTS ON THE ISSUE OF EQUIPMENT OF MEDICAL INSTITUTIONS WITH OPHTHALMOLOGY DEVICES

    Directory of Open Access Journals (Sweden)

    S. V. Seraphimov

    2017-01-01

    Full Text Available Introduction. The problem of limited accessibility and quality of ophthalmic medical care remains one of the leading ones in the national healthcare. This article presents results of the survey conducted among ophthalmologists about the effect of large-scale equipment of all medical institutions in the Leningrad Region with modern ophthalmologic devices over the recent years.Objective is to determine the contribution of the health care modernization program to equipping the medical institutions of the Leningrad Region with modern ophthalmologic medical devices, and to identify the main areas for improving the ophthalmologic care for residents of the Leningrad region with cataracts.Materials and methods. According to a specially developed questionnaire, 105 ophthalmologists from the Leningrad Region were interviewed. The survey was conducted among physicians working both in out-patient medical facilities and in medical facilities with in-patient modalities.Results. The results of the study confirmed positive changes that occurred in recent years as a result of equipping medical institutions with modern medical devices. Almost two-thirds (59.9% of respondents noted that equipping with modern medical devices had a significant impact on the quality of the medical and diagnostic measures carried out in healthcare facilities of the region.Conclusions. The equipment had a significant impact on the diagnosis and treatment of all kinds of diseases of the eye and its appendages, especially such eye disease which is so common among the population of the Leningrad Region as cataracts (75.0 per 100 ophthalmologists surveyed. At the same time, in spite of these efforts, the standard for equipping ophthalmologic departments in individual medical institutions has not been fully provided. Only every fifth (20.9% ophthalmologist noted during the survey that the list of available ophthalmic devices was sufficient, and that they all worked properly.

  4. Funding models for outreach ophthalmology services.

    Science.gov (United States)

    Turner, Angus W; Mulholland, Will; Taylor, Hugh R

    2011-01-01

    This paper aims to describe funding models used and compare the effects of funding models for remuneration on clinical activity and cost-effectiveness in outreach eye services in Australia. Cross-sectional case study based in remote outreach ophthalmology services in Australia. Key stake-holders from eye services in nine outreach regions participated in the study. Semistructured interviews were conducted to perform a qualitative assessment of outreach eye services' funding mechanisms. Records of clinical activity were used to statistically compare funding models. Workforce availability (supply of ophthalmologists), costs of services, clinical activity (surgery and clinic consultation rates) and waiting times. The supply of ophthalmologists (full-time equivalence) to all remote regions was below the national average (up to 19 times lower). Cataract surgery rates were also below national averages (up to 10 times lower). Fee-for-service funding significantly increased clinical activity. There were also trends to shorter waiting times and lower costs per attendance. For outreach ophthalmology services, the funding model used for clinician reimbursement may influence the efficiency and costs of the services. Fee-for-service funding models, safety-net funding options or differential funding/incentives need further exploration to ensure isolated disadvantaged areas prone to poor patient attendance are not neglected. In order for outreach eye health services to be sustainable, remuneration rates need to be comparable to those for urban practice. © 2011 The Authors. Clinical and Experimental Ophthalmology © 2011 Royal Australian and New Zealand College of Ophthalmologists.

  5. Foundation of the American Academy of Ophthalmology

    Science.gov (United States)

    ... Plastic Surgery Center Laser Surgery Education Center Redmond Ethics Center Global Ophthalmology Guide Eye ... and Planned Giving Ophthalmic Business Council Orbital Gala Orbital Gala Overview Why Attend ...

  6. Crowdsourcing: an overview and applications to ophthalmology.

    Science.gov (United States)

    Wang, Xueyang; Mudie, Lucy; Brady, Christopher J

    2016-05-01

    Crowdsourcing involves the use of the collective intelligence of online communities to produce solutions and outcomes for defined objectives. The use of crowdsourcing is growing in many scientific areas. Crowdsourcing in ophthalmology has been used in basic science and clinical research; however, it also shows promise as a method with wide-ranging applications. This review presents current findings on the use of crowdsourcing in ophthalmology and potential applications in the future. Crowdsourcing has been used to distinguish normal retinal images from images with diabetic retinopathy; the collective intelligence of the crowd was able to correctly classify 81% of 230 images (19 unique) for US$1.10/eye in 20 min. Crowdsourcing has also been used to distinguish normal optic discs from abnormal ones with reasonable sensitivity (83-88%), but low specificity (35-43%). Another study used crowdsourcing for quick and reliable manual segmentation of optical coherence tomography images. Outside of ophthalmology, crowdsourcing has been used for text and image interpretation, language translation, and data analysis. Crowdsourcing has the potential for rapid and economical data processing. Among other applications, it could be used in research settings to provide the 'ground-truth' data, and in the clinical settings to relieve the burden of image processing on experts.

  7. Novel use of smart tablet computer for ophthalmology

    Directory of Open Access Journals (Sweden)

    Zhao-Tian Zhang

    2015-01-01

    Full Text Available AIM:To identify and categorize ophthalmology-relevant apps for the iPad tablet computer as a source for ophthalmic practices on the Apple's App Store.METHODS: The Apple's App Store was searched for ophthalmology-relevant apps from January 2013 to August 2013. Eligible apps were identified and downloaded into the iPad tablet computers, and then categorized according to the apps' initial contents and our using experiences. Methods about how to use the iPad's built-in functions of instant video call(FaceTime®and automatic data storage technology(iCloud®were also described together with the apps. Other operating systems of Microsoft's Window Phone and Google's Android were also searched for ophthalmology-relevant apps.RESULTS: The keywords for searching on the Apple's App Store were “ophthalmology” and “eye”. And we could found 111 eligible apps with the former keyword, and 452 ones with the latter one. The integrated uses of the iPad tablet computer were then categorized into five aspects. Based on our clinical practice, we finally summarized the advantages and disadvantages of the iPad tablet computer for ophthalmic practices. However, ophthalmology-relevant apps were found to be very limited in number on the other two platforms.CONCLUSION: The integrated use of self built-in apps and third-party apps can facilitate our clinical work in examination, telemedicine, reference, disease education and literature searching. More studies are needed to verify its validation and reliability in the professional fields, especially eye examinations.

  8. Clinical safety and professional liability claims in Ophthalmology.

    Science.gov (United States)

    Dolz-Güerri, F; Gómez-Durán, E L; Martínez-Palmer, A; Castilla Céspedes, M; Arimany-Manso, J

    2017-11-01

    Patient safety is an international public health priority. Ophthalmology scientific societies and organisations have intensified their efforts in this field. As a tool to learn from errors, these efforts have been linked to the management of medical professional liability insurance through the analysis of claims. A review is performed on the improvements in patient safety, as well as professional liability issues in Ophthalmology. There is a high frequency of claims and risk of economic reparation of damage in the event of a claim in Ophthalmology. Special complaints, such as wrong surgery or lack of information, have a high risk of financial compensation and need strong efforts to prevent these potentially avoidable events. Studies focused on pathologies or specific procedures provide information of special interest to sub-specialists. The specialist in Ophthalmology, like any other doctor, is subject to the current legal provisions and appropriate mandatory training in the medical-legal aspects of health care is essential. Professionals must be aware of the fundamental aspects of medical professional liability, as well as specific aspects, such as defensive medicine and clinical safety. The understanding of these medical-legal aspects in the routine clinical practice can help to pave the way towards a satisfactory and safe professional career, and help in increasing patient safety. The aim of this review is to contribute to this training, for the benefit of professionals and patients. Copyright © 2017 Sociedad Española de Oftalmología. Publicado por Elsevier España, S.L.U. All rights reserved.

  9. Advanced Laser-Based Techniques for Gas-Phase Diagnostics in Combustion and Aerospace Engineering.

    Science.gov (United States)

    Ehn, Andreas; Zhu, Jiajian; Li, Xuesong; Kiefer, Johannes

    2017-03-01

    Gaining information of species, temperature, and velocity distributions in turbulent combustion and high-speed reactive flows is challenging, particularly for conducting measurements without influencing the experimental object itself. The use of optical and spectroscopic techniques, and in particular laser-based diagnostics, has shown outstanding abilities for performing non-intrusive in situ diagnostics. The development of instrumentation, such as robust lasers with high pulse energy, ultra-short pulse duration, and high repetition rate along with digitized cameras exhibiting high sensitivity, large dynamic range, and frame rates on the order of MHz, has opened up for temporally and spatially resolved volumetric measurements of extreme dynamics and complexities. The aim of this article is to present selected important laser-based techniques for gas-phase diagnostics focusing on their applications in combustion and aerospace engineering. Applicable laser-based techniques for investigations of turbulent flows and combustion such as planar laser-induced fluorescence, Raman and Rayleigh scattering, coherent anti-Stokes Raman scattering, laser-induced grating scattering, particle image velocimetry, laser Doppler anemometry, and tomographic imaging are reviewed and described with some background physics. In addition, demands on instrumentation are further discussed to give insight in the possibilities that are offered by laser flow diagnostics.

  10. [Neuro-ophthalmology: the eye as a window to the brain].

    Science.gov (United States)

    Kesler, Anat

    2013-02-01

    Neuro-ophthalmology focuses on the diagnosis and treatment of visual disorders related to the neurological system rather than the globe itself. Being a subspecialty of both neurology and ophthalmology, it requires specialized training and expertise in diseases of the eye, brain, nerves and muscles. Commonly encountered pathologies in neuro-ophthalmology include: optic neuropathies (such as optic neuritis and ischemic optic neuropathy), visual field loss (transient, constant, unexplained), transient visual loss, unspecified visual disturbances, diplopia, abnormal eye movements, thyroid eye disease, myasthenia gravis, anisocoria, and eyelid abnormalities. The current issue of "Harefuah" is dedicated to contemporary knowledge in neuro-opthalmology, and spans from studies of neuromyelitis optica (NMO), ischemic optic neuropathies, and optic neuropathies induced by phosphodiesterase inhibitors, to the management of sight-threatening carotid-cavernous fistulas, and more. These studies emphasize the importance of an interdisciplinary treatment team consisting of a neuro-ophthalmologist, a neuro-radiologist, and sometimes, even a neuro-surgeon. Such an approach may prove to be beneficial to the patient, by optimizing follow-up and treatment decisions. This issue emphasizes how a correct and timely diagnosis is of paramount significance in patients with neuro-ophthalmological disorders.

  11. 3D Printing: Print the future of ophthalmology.

    Science.gov (United States)

    Huang, Wenbin; Zhang, Xiulan

    2014-08-26

    The three-dimensional (3D) printer is a new technology that creates physical objects from digital files. Recent technological advances in 3D printing have resulted in increased use of this technology in the medical field, where it is beginning to revolutionize medical and surgical possibilities. It is already providing medicine with powerful tools that facilitate education, surgical planning, and organ transplantation research. A good understanding of this technology will be beneficial to ophthalmologists. The potential applications of 3D printing in ophthalmology, both current and future, are explored in this article. Copyright 2014 The Association for Research in Vision and Ophthalmology, Inc.

  12. Review of Physicochemical-Based Diagnostic Techniques for Assessing Insulation Condition in Aged Transformers

    Directory of Open Access Journals (Sweden)

    Janvier Sylvestre N’cho

    2016-05-01

    Full Text Available A power transformer outage has a dramatic financial consequence not only for electric power systems utilities but also for interconnected customers. The service reliability of this important asset largely depends upon the condition of the oil-paper insulation. Therefore, by keeping the qualities of oil-paper insulation system in pristine condition, the maintenance planners can reduce the decline rate of internal faults. Accurate diagnostic methods for analyzing the condition of transformers are therefore essential. Currently, there are various electrical and physicochemical diagnostic techniques available for insulation condition monitoring of power transformers. This paper is aimed at the description, analysis and interpretation of modern physicochemical diagnostics techniques for assessing insulation condition in aged transformers. Since fields and laboratory experiences have shown that transformer oil contains about 70% of diagnostic information, the physicochemical analyses of oil samples can therefore be extremely useful in monitoring the condition of power transformers.

  13. Vincenz Fukala (1847-1911): versatile surgeon and early historian of ophthalmology.

    Science.gov (United States)

    Schmidt, Dieter; Grzybowski, Andrzej

    2011-01-01

    Vincenz Fukala is best known for his technique of discission and linear extraction of the lens in young, highly myopic eyes--the technique adopted by Harold Ridley in preparation for lens implantation in young patients. He was Polish and trained in Vienna under Karl Ferdinand. von Arlt. Fukala practiced first in Pilsen (1889-1894), but returned to Vienna in 1895. He studied trachoma in Egypt in 1872. His research on scrofulous eye disease led him twice to the United States, in 1891 and 1892. Fukala also developed highly successful, pioneering techniques for the treatment of ectropion in blepharitis, of trachoma, and of shallow sockets following enucleation. In glaucoma, he recommended early iridectomy of the fellow eye when the first eye has gone blind. He was also an expert on the history of ancient European texts and of Arabic ophthalmology. Copyright © 2011 Elsevier Inc. All rights reserved.

  14. Perspective of ophthalmology residents in the United States about residency programs and competency in relation to the International Council of Ophthalmology guidelines.

    Science.gov (United States)

    Abdelfattah, Nizar Saleh; Radwan, Ahmed E; Sadda, Srinivas R

    2016-09-01

    To evaluate the perspective of ophthalmology residents in the US about their residency programs and compare the competency of residency programs to international competency levels set by the International Council of Ophthalmology (ICO). A cross-sectional web-based survey extracted from the ICO published competency standards was sent to program directors of ophthalmology residency programs in the US to forward it to current PGY-3, 4 residents, and residency graduates from 2011 to 2014. Eighty-seven responses were received, comprising 61 residents and 26 graduates. Most respondents were highly satisfied with their programs (93.6%). Clinic-based training was rated satisfactorily. Insufficient exposure to low-vision rehabilitation (38.5%), refraction and contact lenses prescription (38.5%), and vitreo-retinal surgeries (38.5%) was reported. Respondents were satisfied with their overall surgical experiences, with the vast majority (>83%) rating case volume, complexity, and variety as satisfactory or better. A significant group stated they had insufficient exposure to extra-capsular cataract extraction (26.3%), refractive surgery (19.7%), and orbital surgery (64.5%). All graduates surveyed passed their Ophthalmic Knowledge Assessment Program (OKAP) examinations, and 72% felt their residency programs adequately prepared them for the examinations. All respondents reported insufficient training in certain nonclinical areas, such as practice management, staffing, and administration skills. Ophthalmology residents in the US express high levels of satisfaction with their residency training programs. While most programs adequately address most ICO core objectives, certain curriculum modifications should be considered.

  15. Competency based ophthalmology training curriculum for ...

    African Journals Online (AJOL)

    Background: The establishment of a credible, defensible and acceptable “formal competency based ophthalmology training curriculum for undergraduate medical and dental students” is fundamental to program recognition, monitoring and evaluation. The University of Zimbabwe College of Health Sciences (UZ-CHS) has ...

  16. Diagnostic techniques used in controlled thermonuclear research at Harwell

    Energy Technology Data Exchange (ETDEWEB)

    Harding, G N; Dellis, A N; Gibson, A; Jones, B; Lees, D J; McWhirter, R W.P.; Ramsden, S A; Ward, S [UK Atomic Energy Authority, AERE, Harwell (United Kingdom)

    1958-07-01

    This paper is a general survey of the lines along which diagnostic methods (spectroscopy, electrical measurements, and the study of high energy radiations) are developing at Harwell, and indicates the results which have been obtained so far. Many of the techniques are in a rudimentary state, and most of the Zeta experiments are incomplete.

  17. Diagnostics of anterior eye segment in cats and dogs

    Directory of Open Access Journals (Sweden)

    Hadži-Milić Milan

    2006-01-01

    Full Text Available Diagnostics of the anterior segment of the eye present the most frequent diagnostics implemented in ophthalmology and by most veterinary practicians as well. This paper presents the complete diagnostics in the most concise form possible. The procedure with animals is presented first, followed by the equipment, and then anamnesis. The following diagnostic methods are presented: examination in a lighted room which include an examination from a distance, taking a smear, the Schirmer tear test (STT, an examination from close by, examination in a dark room which comprises the elementary examinations, such as the use of focal lighting and examination using a direct ophthalmoscope, and special examination in a dark room, such as biomicroscopy, gonioscopy and keratoscopy. Additional examination methods are also included.

  18. Electrical-Based Diagnostic Techniques for Assessing Insulation Condition in Aged Transformers

    Directory of Open Access Journals (Sweden)

    Issouf Fofana

    2016-08-01

    Full Text Available The condition of the internal cellulosic paper and oil insulation are of concern for the performance of power transformers. Over the years, a number of methods have been developed to diagnose and monitor the degradation/aging of the transformer internal insulation system. Some of this degradation/aging can be assessed from electrical responses. Currently there are a variety of electrical-based diagnostic techniques available for insulation condition monitoring of power transformers. In most cases, the electrical signals being monitored are due to mechanical or electric changes caused by physical changes in resistivity, inductance or capacitance, moisture, contamination or aging by-products in the insulation. This paper presents a description of commonly used and modern electrical-based diagnostic techniques along with their interpretation schemes.

  19. Trends in Authorship of Articles in Major Ophthalmology Journals by Gender, 2002-2014.

    Science.gov (United States)

    Mimouni, Michael; Zayit-Soudry, Shiri; Segal, Ori; Barak, Yoreh; Nemet, Arie Y; Shulman, Shiri; Geffen, Noa

    2016-08-01

    To evaluate trends in the prevalence of women authors in ophthalmology in recent years. Cohort study. Authors listed in publications of 6 leading ophthalmology journals between January 2002 and December 2014. Using the PubMed search engine, we conducted an observational study of trends in gender distribution of all authors in 6 leading ophthalmology journals between January 2002 and December 2014. In multiauthored articles, the first listed author often is the lead investigator and the last author is the senior author. Therefore, the full names and positions (first, middle, or last) of all authors in every article were collected. A Google-based name identifier was used to assign the gender of authors. Proportion of women authors throughout the study period in all journals, general ophthalmology versus subspecialty journals, and basic science versus clinical research journals. Furthermore, we assessed the proportion of women in different authorship positions (first, middle, and last). A total of 102 254 authors from 23 026 published articles were analyzed. There was a significant rise over time in the percentage of women authors, with a steeper slope for first authors than for last authors (P<0.001), although in 2014, women authors were less than the 50% mark in all categories of authorship. The rise in the percentage of women authors was similar in basic and clinical research, but was steeper for first authorship than for last authorship (P<0.001). In all 3 authorship positions (first, middle, or last), women's contributions consistently were higher in basic research publications. The rise in the percentage of women authors was significantly steeper for general journals than for subspecialty journals (P<0.001). There was no significant rise for last authorship in subspecialty journals. In all 3 authorship positions, the proportion of women was consistently higher in general ophthalmology journals than for subspecialty journals. Despite an overall increase in

  20. A new techniques in the physics of diagnostic radiology

    International Nuclear Information System (INIS)

    Jennings, R.J.

    1987-01-01

    The basic physics involved in the generation of X-rays and in the energy dependence of their interaction with matter are reviewed. Some applications of those ideas in both conventional X-ray imaging and in new imaging techniques are studied. Methods for the optimization of X-ray diagnostic imaging system are discussed. (M.A.C.) [pt

  1. Decision support systems and applications in ophthalmology: literature and commercial review focused on mobile apps.

    Science.gov (United States)

    de la Torre-Díez, Isabel; Martínez-Pérez, Borja; López-Coronado, Miguel; Díaz, Javier Rodríguez; López, Miguel Maldonado

    2015-01-01

    The growing importance that mobile devices have in daily life has also reached health care and medicine. This is making the paradigm of health care change and the concept of mHealth or mobile health more relevant, whose main essence is the apps. This new reality makes it possible for doctors who are not specialist to have easy access to all the information generated in different corners of the world, making them potential keepers of that knowledge. However, the new daily information exceeds the limits of the human intellect, making Decision Support Systems (DSS) necessary for helping doctors to diagnose diseases and also help them to decide the attitude that has to be taken towards these diagnoses. These could improve the health care in remote areas and developing countries. All of this is even more important in diseases that are more prevalent in primary care and that directly affect the people's quality of life, this is the case in ophthalmological problems where in first patient care a specialist in ophthalmology is not involved. The goal of this paper is to analyse the state of the art of DSS in Ophthalmology. Many of them focused on diseases affecting the eye's posterior pole. For achieving the main purpose of this research work, a literature review and commercial apps analysis will be done. The used databases and systems will be IEEE Xplore, Web of Science (WoS), Scopus, and PubMed. The search is limited to articles published from 2000 until now. Later, different Mobile Decision Support System (MDSS) in Ophthalmology will be analyzed in the virtual stores for Android and iOS. 37 articles were selected according their thematic (posterior pole, anterior pole, Electronic Health Records (EHRs), cloud, data mining, algorithms and structures for DSS, and other) from a total of 600 found in the above cited databases. Very few mobile apps were found in the different stores. It can be concluded that almost all existing mobile apps are focused on the eye's posterior

  2. History and development of ophthalmology in Taiwan

    Directory of Open Access Journals (Sweden)

    Yu-Chih Hou

    2016-12-01

    Full Text Available Western medicine was first introduced to Taiwan by medical missionaries in the mid-19th century. Modernization of medicine was systematically transplanted to Taiwan in the Japanese colonial period, and ophthalmology was established third among hospital departments, following internal medicine and surgery. Dr Hidetaka Yamaguchi, an ophthalmologist, was the first head of the Taihoku Hospital, later known as National Taiwan University Hospital (NTUH; Taipei, Taiwan. Ophthalmologists during the colonial period conducted studies on tropical and infectious eye diseases. After World War II, ophthalmologists at NTUH played an important role in medical education, residency training, studies, and teaching. Dr Yan-Fei Yang established the Taiwan Ophthalmological Society in 1960 and instituted its official journal in 1962. Dr Ho-Ming Lin established the Department of Ophthalmology at the Tri-Service General Hospital in the 1950s and the Veterans General Hospital in the 1960s. Taiwan ophthalmologists eradicated trachoma by 1971. Cataract surgery and penetrating keratoplasty were initially performed in the 1960s. Currently, there are about 1600 ophthalmologists in Taiwan conducting an estimated 120,000 cataract surgeries and 600 corneal transplantations annually. Many subspecialty societies have been established recently that serve to educate Taiwanese ophthalmologists and to connect with international ophthalmic societies. Taiwan ophthalmologists continue to contribute to the advancement of ophthalmic knowledge globally.

  3. Ophthalmology on social networking sites: an observational study of Facebook, Twitter, and LinkedIn.

    Science.gov (United States)

    Micieli, Jonathan A; Tsui, Edmund

    2015-01-01

    The use of social media in ophthalmology remains largely unknown. Our aim was to evaluate the extent and involvement of ophthalmology journals, professional associations, trade publications, and patient advocacy and fundraising groups on social networking sites. An archived list of 107 ophthalmology journals from SCImago, trade publications, professional ophthalmology associations, and patient advocacy organizations were searched for their presence on Facebook, Twitter, and LinkedIn. Activity and popularity of each account was quantified by using the number of "likes" on Facebook, the number of followers on Twitter, and members on LinkedIn. Of the 107 journals ranked by SCImago, 21.5% were present on Facebook and 18.7% were present on Twitter. Journal of Community Eye Health was the most popular on Facebook and JAMA Ophthalmology was most popular on Twitter. Among the 133 members of the International Council of Ophthalmology, 17.3% were present on Facebook, 12.8% were present on Twitter, and 7.5% were present on LinkedIn. The most popular on Facebook was the International Council of Ophthalmology, and the American Academy of Ophthalmology was most popular on Twitter and LinkedIn. Patient advocacy organizations were more popular on all sites compared with journals, professional association, and trade publications. Among the top ten most popular pages in each category, patient advocacy groups were most active followed by trade publications, professional associations, and journals. Patient advocacy groups lead the way in social networking followed by professional organizations and journals. Although some journals use social media, most have yet to engage its full potential and maximize the number of potential interested individuals.

  4. Impact of fellowship training on research productivity in academic ophthalmology.

    Science.gov (United States)

    Huang, Grace; Fang, Christina H; Lopez, Santiago A; Bhagat, Neelakshi; Langer, Paul D; Eloy, Jean Anderson

    2015-01-01

    To assess whether scholarly impact of academic ophthalmologists, as measured using the h-index, is affected by fellowship training status and to further characterize differences in productivity among the various subspecialties and by departmental rank. A descriptive and correlational design was used. In total, 1440 academic ophthalmologists from 99 ophthalmology training programs were analyzed. The h-index data were obtained from the Scopus database. Faculty members were classified by academic rank and grouped into 10 categories based on fellowship training: anterior segment, corneal and external disease, glaucoma, uveitis and ocular immunology, vitreoretinal disease, ophthalmic plastic surgery, pediatric ophthalmology, neuro-ophthalmology, ophthalmic pathology, and "other." A one-way analysis of variance or Student t test using Microsoft Excel and "R" statistical software were used for comparison of continuous variables, with significance set at p productivity, as measured using the h-index, than non-fellowship-trained ophthalmologists in this study (p productivity compared with those in other ophthalmology subspecialties (p productivity with increasing academic rank from Assistant Professor to Professor (p productivity between fellowship-trained and non-fellowship-trained ophthalmologists existed individually only at the level of Assistant Professor (p productivity increases with departmental academic rank from Assistant Professor to Professor. Copyright © 2015 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.

  5. [Teleconsultation network for ophthalmology--experiences and results].

    Science.gov (United States)

    Zahlmann, G; Walther, H D; Liesenfeld, B; Kaatz, H; Kluthe, S; Fabian, E; Klaas, D; Schnarr, K D; Neubauer, L; Obermaier, M; Wegner, A; Mertz, M; Mann, G

    1998-02-01

    Telemedical services for ophthalmology are developed within the OPHTEL project, which has been funded by the European Union and by the Bavarian government in the Bavaria-online initiative. Seven private ophthalmologists, one university eye clinic, one clinical Diabetes center and an informatics research institute are connected within a teleconsultation network. Asynchronous (based on Internet E-Mail) and synchronous (based on ISDN-mediated videoconferencing tools) types of teleconsultations are realized. 86 teleconsultations (62 asynchronous, 23 synchronous) took place within the first 10 months. Complex and rare eye diseases as well as interdisciplinary questions (ophthalmology--diabetology) are the main area of medical communication interest. Legal and security problems are discussed. Telemedical services must be understood as a complete process of medical care on the basis of modern communication technologies, which influences also the management of this process.

  6. On-line diagnostic techniques for air-operated control valves based on time series analysis

    International Nuclear Information System (INIS)

    Ito, Kenji; Matsuoka, Yoshinori; Minamikawa, Shigeru; Komatsu, Yasuki; Satoh, Takeshi.

    1996-01-01

    The objective of this research is to study the feasibility of applying on-line diagnostic techniques based on time series analysis to air-operated control valves - numerous valves of the type which are used in PWR plants. Generally the techniques can detect anomalies by failures in the initial stages for which detection is difficult by conventional surveillance of process parameters measured directly. However, the effectiveness of these techniques depends on the system being diagnosed. The difficulties in applying diagnostic techniques to air-operated control valves seem to come from the reduced sensitivity of their response as compared with hydraulic control systems, as well as the need to identify anomalies in low level signals that fluctuate only slightly but continuously. In this research, simulation tests were performed by setting various kinds of failure modes for a test valve with the same specifications as of a valve actually used in the plants. Actual control signals recorded from an operating plant were then used as input signals for simulation. The results of the tests confirmed the feasibility of applying on-line diagnostic techniques based on time series analysis to air-operated control valves. (author)

  7. TOF technique for laser-driven proton beam diagnostics for the ELIMED beamline

    International Nuclear Information System (INIS)

    Milluzzo, G.; Scuderi, V.; Amico, A.G.; Cirrone, G.A.P.; Cuttone, G.; Larosa, G.; Leanza, R.; Petringa, G.; Pipek, J.; Romano, F.; Napoli, M. De; Dostal, J.; Margarone, D.; Schillaci, F.; Velyhan, A.

    2017-01-01

    The Time of Flight (TOF) method for laser-driven ion beam diagnostics has been extensively investigated so far for low energy ion diagnostics and several works, reported in literature [1,2], have shown its efficiency in the measurement of particle beam characteristics such as ion species, energy spectrum and current. Moreover, such technique allows obtaining a shot-to-shot on-line monitoring of optically accelerated particles, necessary to control the reproducibility of the accelerated beam and to deliver a beam suitable for any kind of applications. For this reason, the ELIMED beamline [3,4], which will be entirely developed at INFN-LNS and installed in 2017 within the ion beamline ELIMAIA (ELI Multidisciplinary Applications of laser-Ion Acceleration) experimental hall at ELI-Beamlines in Prague, will be equipped with an on-line diagnostics system composed by silicon carbide and diamond detectors, using the TOF technique. In this contribution, the procedure developed for TOF signal analysis will be briefly reported.

  8. Assessment of Durability of Online and Multisensory Learning Using an Ophthalmology Model.

    Science.gov (United States)

    Lippa, Linda Mottow; Anderson, Craig L

    2015-10-01

    To explore the impact of online learning and multisensory small-group teaching on acquisition and retention of specialty knowledge and diagnostic skills during a third-year family medicine rotation. Exploratory, observational, longitudinal, and multiple-skill measures. Two medical school classes (n = 199) at a public medical school in California. Students engaged in online self-study, small-group interactive diagnostic sessions, picture identification of critical pathologic features, and funduscopic simulator examinations. The authors compared performance on testing immediately after online learning with testing at end-rotation, as well as picture identification versus simulator diagnostic ability in students with (n = 94) and without (n = 105) practice tracing contours on whiteboard projections of those same slides depicting fundus pathologic features of common systemic diseases. Picture identification, accuracy of funduscopic descriptions, online module post-tests, and end-rotation tests. Proprioceptive reinforcement of fundus pattern recognition significantly reduced the need for remediation for misdiagnosing optic disc edema during end-rotation funduscopic simulator testing, but it had no effect on fundus pattern recognition or diagnostic ability overall. Near-perfect immediate online post-test scores contrasted sharply with poor end-rotation scores on an in-house test (average, 59.4%). Rotation timing was not a factor because the patterns remained consistent throughout the academic school year. Neither multisensory teaching nor online self-study significantly improved retention of ophthalmic knowledge and diagnostic skills by the end of a month-long third-year rotation. Timing such training closer to internship when application is imminent may enhance students' appreciation for its value and perhaps may improve retention. Pulsed quizzes over time also may be necessary to motivate students to retain the knowledge gained. Copyright © 2015 American Academy of

  9. Using Pattern Classification and Recognition Techniques for Diagnostic and Prediction

    Directory of Open Access Journals (Sweden)

    MORARIU, N.

    2007-04-01

    Full Text Available The paper presents some aspects regarding the joint use of classification and recognition techniques for the activity evolution diagnostication and prediction by means of a set of indexes. Starting from the indexes set there is defined a measure on the patterns set, measure representing a scalar value that characterizes the activity analyzed at each time moment. A pattern is defined by the values of the indexes set at a given time. Over the classes set obtained by means of the classification and recognition techniques is defined a relation that allows the representation of the evolution from negative evolution towards positive evolution. For the diagnostication and prediction the following tools are used: pattern recognition and multilayer perceptron. The data set used in experiments describes the pollution due to CO2 emission from the consumption of fuels in Europe. The paper also presents the REFORME software written by the authors and the results of the experiment obtained with this software.

  10. Robotic-assisted surgery in ophthalmology.

    Science.gov (United States)

    de Smet, Marc D; Naus, Gerrit J L; Faridpooya, Koorosh; Mura, Marco

    2018-05-01

    Provide an overview of the current landscape of robotics in ophthalmology, including the pros and cons of system designs, the clinical development path, and the likely future direction of the field. Robots designed for eye surgery should meet certain basic requirements. Three designs are currently being developed: smart surgical tools such as the steady hand, comanipulation devices and telemanipulators using either a fixed or virtual remote center of motion. Successful human intraocular surgery is being performed using the Preceyes surgical system. Another telemanipulation robot, the da Vinci Surgical System, has been used to perform a pterygium repair in humans and was successful in ex-vivo corneal surgery despite its nonophthalmic design. Apart from Preceyes' BV research platform, none of the currently eye-specific systems has reached a commercial stage. Systems are likely to evolve from robotic assistance during specific procedural steps to semiautonomous surgery, as smart sensors are introduced to enhance the basic functionalities of robotic systems. Robotics is still in its infancy in ophthalmology but is rapidly reaching a stage wherein it will be introduced into everyday ophthalmic practice. It will most likely be introduced first for demanding vitreo-retinal procedures, followed by anterior segment applications.

  11. General ophthalmology | Bekibele | Nigerian Journal of ...

    African Journals Online (AJOL)

    Transactions of the Ophthalmological Society of Nigeria: Proceedings of the annual OSN Conference, Jos, Nigeria, August 25–28, 2015. Full Text: EMAIL FREE FULL TEXT EMAIL FREE FULL TEXT · DOWNLOAD FULL TEXT DOWNLOAD FULL TEXT · AJOL African Journals Online. HOW TO USE AJOL... for Researchers ...

  12. General ophthalmology | Bekibele | Nigerian Journal of ...

    African Journals Online (AJOL)

    Proceedings from the Ophthalmological Society of Nigeria Conference, 2014. Full Text: EMAIL FREE FULL TEXT EMAIL FREE FULL TEXT · DOWNLOAD FULL TEXT DOWNLOAD FULL TEXT · AJOL African Journals Online. HOW TO USE AJOL... for Researchers · for Librarians · for Authors · FAQ's · More about AJOL ...

  13. Communication Skills Training in Ophthalmology: Results of a Needs Assessment and Pilot Training Program.

    Science.gov (United States)

    Mishra, Anuradha; Browning, David; Haviland, Miriam J; Jackson, Mary Lou; Luff, Donna; Meyer, Elaine C; Talcott, Katherine; Kloek, Carolyn E

    To conduct a needs assessment to identify gaps in communication skills training in ophthalmology residency programs and to use these results to pilot a communication workshop that prepares residents for difficult conversations. A mixed-methods design was used to perform the needs assessment. A pre-and postsurvey was administered to workshop participants. Mass Eye and Ear Infirmary, Harvard Medical School (HMS), Department of Ophthalmology. HMS ophthalmology residents from postgraduate years 2-4 participated in the needs assessment and the workshop. Ophthalmology residency program directors in the United States participated in national needs assessment. Ophthalmology program directors across the United States were queried on their perception of resident communication skills training through an online survey. A targeted needs assessment in the form of a narrative exercise captured resident perspectives on communication in ophthalmology from HMS residents. A group of HMS residents participated in the pilot workshop and a pre- and postsurvey was administered to participants to assess its effectiveness. The survey of program directors yielded a response rate of 40%. Ninety percent of respondents agreed that the communication skills training in their programs could be improved. Fifteen of 24 residents (62%) completed the needs assessment. Qualitative analysis of the narrative material revealed four themes; (1) differing expectations, (2) work role and environment, (3) challenges specific to ophthalmology, and (4) successful strategies adopted. Nine residents participated in the workshop. There was a significant improvement post-workshop in resident reported scores on their ability to manage their emotions during difficult conversations (p = 0.03). There is an opportunity to improve communication skills training in ophthalmology residency through formalized curriculum. Copyright © 2017 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights

  14. General Information | Bekibele | Nigerian Journal of Ophthalmology

    African Journals Online (AJOL)

    Nigerian Journal of Ophthalmology. Journal Home · ABOUT THIS JOURNAL · Advanced Search · Current Issue · Archives · Journal Home > Vol 22, No 1 (2014) >. Log in or Register to get access to full text downloads.

  15. [Ophthalmological symptoms of measles and their treatment].

    Science.gov (United States)

    Végh, Mihály; Hári-Kovács, András; Roth, Hans-Walter; Facskó, Andrea

    2017-10-01

    Measles, caused by the Morbilli virus, is a highly (about 95 %) contagious disease affecting primarily children, but without proper immunisation, adults can also be infected. The leading symptoms of the disease are high fever that presents after an incubation period of 9-10 days and the red rash that begins several days after the fever starts. Beyond specific generalized symptoms, measles may have ocular symptoms. The most commonly occurring conjunctivitis, the so-called "red eye symptom", is not characteristic only for measles infection, however, by taking the generalized symptoms it can suggest the diagnosis at the beginning of the disease. Conjunctivitis of varying severity is noticed in the half of the cases without using ophthalmological instrumentation. Using ophthalmological instrumentation, the mild forms of conjunctivitis can be diagnosed, by meticulous ophthalmological examination, further eye diseases can be discovered. The viral conjunctivitis can progress to keratitis and bacterial superinfection can occur. If the infection presents in childhood it can affect the posterior segment. The fight against measles is very effective in Hungary since the vaccination has been introduced, and the lack of vaccination is also the primary cause of the risk to the disease. In the diagnosis, symptomatic treatment of the disease and the curbing of possible mass infections, the practicing physician (general practitioner) has a key role. The correct care of the infected patient in Hungary is provided by a methodological letter, professional information and legal guides. Orv Hetil. 2017; 158(39): 1523-1527.

  16. Two cases of colossal heamtometra in old women with a difficult preoperative diagnostic technique

    International Nuclear Information System (INIS)

    Aono, Kaname; Fukumoto, Satoru

    1980-01-01

    With the progress in diagnostic imaging techniques, the preoperative diagnostic technique for lesion in the pelvic cavity has become comparatively easy and its clinical usefulness is in high estimation. However, in case of an atypical lesion, it is not always easy to recognize the original organ by traditional imaging pattern. In the present report two cases of colossal hematometra in old women which presented a cystic lesion pattern are dealt with and discussed from a point of medical imagings for diagnosis. (author)

  17. Application of traditional indexes and adverse events in the ophthalmologic perioperative medical quality evaluation during 2010-2012

    Directory of Open Access Journals (Sweden)

    Yong-Na Bian

    2015-10-01

    Full Text Available AIM: To evaluate the medical quality of ophthalmologic perioperative period during 2010-2012 in our hospital.METHODS:The relevant data of perioperative period were collected in our hospital during 2010-2012, and the medical quality of perioperative period was evaluated by using the traditional evaluation indexes and adverse events. Whereby, the traditional indicators include vision changes, improving of intraocular pressure, diagnostic accordance rate before and after operation, cure improvement rate, successful rescue rate, and incidence of surgical complications, etc. Adverse events are associated with ophthalmologic perioperative events including pressure sores, postoperative wound infection, drug adverse events, and equipment related adverse events.RESULTS:There were 1483, 1662 and 1931 ophthalmic operations in our hospital in the year 2010, 2011 and 2012, respectively. From traditional index analysis, the proportions of vision improvement for each year were 96.43%, 96.76% and 97.32%, respectively; the rates of intraocular pressure improvement were 87.50%, 85.72% and 90.17%, respectively (P <0.05; the diagnostic accordance rates before and after operation were 99.86%, 99.94% and 99.90%, respectively; cure improvement rates were 99.73%, 99.93% and 99.84%, respectively; the successful rescue rates were 82.98%, 81.46% and 76.66%, respectively; the complications incidence rates were 18.44%, 17.52% and 17.97%, respectively. The negative factor analysis results showed that:among all the patients of ophthalmic surgeries in our hospital during 2010 and 2012, only one case of postoperative wound infection was found in 2011, and also only one case of tumbling in 2010. The adverse drug events for each year were 1 case (0.07%, 2 cases (0.12%, and 4 cases (0.21%, respectively; the medical device adverse events for each year were 3 cases (0.20%, 5 cases (0.30%, and 6 cases (0.31%, respectively. Noticeably, only one case with postoperative infection of

  18. Imaging nuclear medicine techniques for diagnostic evaluation of arterial hypertension

    International Nuclear Information System (INIS)

    Eisenberg, B.M.; Linss, G.

    1989-01-01

    Arterial hypertension may be caused by a malfunction of organs and in turn may lead to secondary organic lesions. Modern diagnostic nuclear medicine is applied for function studies in order to detect or exclude secondary hypertension and functional or perfusion disturbances due to hypertension, or to assess and follow up hemodynamic conditions and cardiac functions prior to and during therapy. The article presents a survey of imaging diagnostic nuclear medicine techniques for the eamination of the heart, the brain, the kidneys and endocrine glands in patients with arterial hypertension, discussing the methods with a view to obtainable information, limits of detection, and indications. (orig.) [de

  19. The Iowa ophthalmology wet laboratory curriculum for teaching and assessing cataract surgical competency

    NARCIS (Netherlands)

    Lee, Andrew G.; Greenlee, Emily; Oetting, Thomas A.; Beaver, Hilary A.; Johnson, A. Tim; Boldt, H. Culver; Abramoff, Michael; Olson, Richard; Carter, Keith

    2007-01-01

    Purpose To describe an ophthalmology wet laboratory (OWL) curriculum for residents in training. Methods Systematic literature review and selection of best practices for use in the OWL learning plan from a single academic ophthalmology program. Results A pretest and posttest of cognitive

  20. LeRC rail accelerators: test designs and diagnostic techniques

    International Nuclear Information System (INIS)

    Zana, L.M.; Kerslake, W.R.; Sturman, J.C.; Wang, S.Y.; Terdan, F.F.

    1984-01-01

    The feasibility of using rail accelerators for various in-space and to-space propulsion applications was investigated. A 1 meter, 24 sq mm bore accelerator was designed with the goal of demonstrating projectile velocities of 15 km/sec using a peak current of 200 kA. A second rail accelerator, 1 meter long with a 156.25 sq mm bore, was designed with clear polycarbonate sidewalls to permit visual observation of the plasma arc. A study of available diagnostic techniques and their application to the rail accelerator is presented. Specific topics of discussion include the use of interferometry and spectroscopy to examine the plasma armature as well as the use of optical sensors to measure rail displacement during acceleration. Standard diagnostics such as current and voltage measurements are also discussed. 15 references

  1. Fusion alpha loss diagnostic for ITER using activation technique

    Czech Academy of Sciences Publication Activity Database

    Bonheure, G.; Hult, M.; González de Orduña, R.; Vermaercke, P.; Murari, A.; Popovichev, S.; Mlynář, Jan

    2011-01-01

    Roč. 86, 6-8 (2011), s. 1298-1301 ISSN 0920-3796. [Symposium on Fusion Technology (SOFT) /26th./. Port o, 27.09.2010-01.10.2010] Institutional research plan: CEZ:AV0Z20430508 Keywords : ITER * fusion product * burning plasma diagnostics * alpha losses * activation technique Subject RIV: BL - Plasma and Gas Discharge Physics Impact factor: 1.490, year: 2011 http://www.sciencedirect.com/science/article/pii/S0920379611002778

  2. [Development of an ophthalmological clinical information system for inpatient eye clinics].

    Science.gov (United States)

    Kortüm, K U; Müller, M; Babenko, A; Kampik, A; Kreutzer, T C

    2015-12-01

    In times of increased digitalization in healthcare, departments of ophthalmology are faced with the challenge of introducing electronic clinical health records (EHR); however, specialized software for ophthalmology is not available with most major EHR sytems. The aim of this project was to create specific ophthalmological user interfaces for large inpatient eye care providers within a hospitalwide EHR. Additionally the integration of ophthalmic imaging systems, scheduling and surgical documentation should be achieved. The existing EHR i.s.h.med (Siemens, Germany) was modified using advanced business application programming (ABAP) language to create specific ophthalmological user interfaces for reproduction and moreover optimization of the clinical workflow. A user interface for documentation of ambulatory patients with eight tabs was designed. From June 2013 to October 2014 a total of 61,551 patient contact details were documented. For surgical documentation a separate user interface was set up. Digital clinical orders for documentation of registration and scheduling of operations user interfaces were also set up. A direct integration of ophthalmic imaging modalities could be established. An ophthalmologist-orientated EHR for outpatient and surgical documentation for inpatient clinics was created and successfully implemented. By incorporation of imaging procedures the foundation of future smart/big data analyses was created.

  3. Assessment of online patient education materials from major ophthalmologic associations.

    Science.gov (United States)

    Huang, Grace; Fang, Christina H; Agarwal, Nitin; Bhagat, Neelakshi; Eloy, Jean Anderson; Langer, Paul D

    2015-04-01

    Patients are increasingly using the Internet to supplement finding medical information, which can be complex and requires a high level of reading comprehension. Online ophthalmologic materials from major ophthalmologic associations should be written at an appropriate reading level. To assess ophthalmologic online patient education materials (PEMs) on ophthalmologic association websites and to determine whether they are above the reading level recommended by the American Medical Association and National Institutes of Health. Descriptive and correlational design. Patient education materials from major ophthalmology websites were downloaded from June 1, 2014, through June 30, 2014, and assessed for level of readability using 10 scales. The Flesch Reading Ease test, Flesch-Kincaid Grade Level, Simple Measure of Gobbledygook test, Coleman-Liau Index, Gunning Fog Index, New Fog Count, New Dale-Chall Readability Formula, FORCAST scale, Raygor Readability Estimate Graph, and Fry Readability Graph were used. Text from each article was pasted into Microsoft Word and analyzed using the software Readability Studio professional edition version 2012.1 for Windows. Flesch Reading Ease score, Flesch-Kincaid Grade Level, Simple Measure of Gobbledygook grade, Coleman-Liau Index score, Gunning Fog Index score, New Fog Count, New Dale-Chall Readability Formula score, FORCAST score, Raygor Readability Estimate Graph score, and Fry Readability Graph score. Three hundred thirty-nine online PEMs were assessed. The mean Flesch Reading Ease score was 40.7 (range, 17.0-51.0), which correlates with a difficult level of reading. The mean readability grade levels ranged as follows: 10.4 to 12.6 for the Flesch-Kincaid Grade Level; 12.9 to 17.7 for the Simple Measure of Gobbledygook test; 11.4 to 15.8 for the Coleman-Liau Index; 12.4 to 18.7 for the Gunning Fog Index; 8.2 to 16.0 for the New Fog Count; 11.2 to 16.0 for the New Dale-Chall Readability Formula; 10.9 to 12.5 for the FORCAST scale; 11

  4. Acquisition and retrieval of ophthalmology academic information

    Directory of Open Access Journals (Sweden)

    Lei Li

    2014-06-01

    Full Text Available This article discusses how to search and access ophthalmology information based on specialized websites and resources by introducing the database, search engines, electronic journals, electronic books and so on. Hope to help ophthalmic practitioners to carry out scientific research and clinical practice.

  5. Dr Adam Zamenhof (1888-1940) and his insight into ophthalmology.

    Science.gov (United States)

    Wincewicz, Andrzej; Sulkowska, Mariola; Lieberman, E James; Bakunowicz-Lazarczyk, Alina; Sulkowski, Stanislaw

    2009-02-01

    Adam Zamenhof was greatly influenced by his father, Ludwik Zamenhof, who designed the international language Esperanto. Like his father, he became an ophthalmologist and joined the Esperanto movement. He published in the field of ophthalmology and was soon chosen as head of an ophthalmology department. He subsequently became Chief of the Orthodox Jewish Hospital at Czystem in Warsaw. He was active in the leadership of the Bialystok-Warsaw Chamber of Medical Doctors. He perished in the Nazi Holocaust (Shoah) but all Zamenhof's ideals that Adam served as a doctor and social activist remain still alive.

  6. Modified Team-Based Learning in an Ophthalmology Clerkship in China.

    Directory of Open Access Journals (Sweden)

    Zheqian Huang

    Full Text Available Team-based learning (TBL is an increasingly popular teaching method in medical education. However, TBL hasn't been well-studied in the ophthalmology clerkship context. This study was to examine the impact of modified TBL in such context and to assess the student evaluations of TBL.Ninety-nine students of an 8-year clinical medicine program from Zhongshan Ophthalmic Centre, Sun Yat-sen University, were randomly divided into four sequential units and assigned to six teams with the same faculty. The one-week ophthalmology clerkship module included traditional lectures, gross anatomy and a TBL module. The effects of the TBL module on student performance were measured by the Individual Readiness Assurance Test (IRAT, the Group Readiness Assurance Test (GRAT, the Group Application Problem (GAP and final examination scores (FESs. Students' evaluations of TBL were measured by a 16-item questionnaire. IRAT and GRAT scores were compared using a paired t-test. One-way analysis of variance (ANOVA and subgroup analysis compared the effects among quartiles that were stratified by the Basic Ophthalmology Levels (BOLs. The BOLs were evaluated before the ophthalmology clerkship.In TBL classes, the GRAT scores were significantly higher than the IRAT scores in both the full example and the BOL-stratified groups. It highlighted the advantages of TBL compared to the individual learning. Quartile-stratified ANOVA comparisons showed significant differences at FES scores (P < 0.01. In terms to IRAT, GRAT and GAP scores, there was no significant result. Moreover, IRAT scores only significantly differed between the first and fourth groups. The FES scores of the first three groups are significantly higher than the fourth group. Gender-specific differences were significant in FES but not the IRAT. Overall, 57.65% of student respondents agreed that TBL was helpful. Male students tended to rate TBL higher than female students.The application of modified TBL to the

  7. Cryotherapy in ophthalmology. Kryotherapie in der Augenheilkunde

    Energy Technology Data Exchange (ETDEWEB)

    Anders, M. (Medizinische Akademie Dresden (Germany))

    1993-01-01

    Ophthalmology is the only medical field in which all of the six known therapeutic applications of low temperature are used. The most important indications are discussed with reference to the corresponding device technology developed at the Department of Cryomedicine of the Dresden Academy of Medicine. (orig.)

  8. Ophthalmologic Disease in HIV Infection: Recent Changes in Pathophysiology and Treatment.

    Science.gov (United States)

    Stewart, Michael W

    2017-10-19

    Ophthalmologic conditions were among the earliest described findings in patients with the acquired immunodeficiency syndrome (AIDS). The purpose of this review is to highlight recent changes in the pathophysiology and management of ophthalmologic conditions in patients infected with the human immunodeficiency virus (HIV). The introduction of highly active antiretroviral therapy (HAART) in 1996 changed ophthalmologic findings from predominantly acute infectious diseases to chronic, slowly progressive, debilitating conditions. HIV-associated neuroretinal disorder infrequently leads to blindness, but it causes visual disability in a large percentage of patients. Cytomegalovirus retinitis is now seen less commonly in the USA, but it remains an important cause of blindness in HIV-infected patients from developing countries. Immune recovery uveitis has emerged as a major cause of visual disability in the USA. As HIV has become a chronic disease, visual disability due to chronic noninfectious diseases have become increasingly important.

  9. Models for joint ophthalmology-optometry patient management.

    Science.gov (United States)

    Kim, John J; Kim, Christine M

    2011-07-01

    American Academy of Ophthalmology (AAO) and American Society of Cataract and Refractive Surgery (ASCRS) presented a joint position paper in February 2000 declaring that they do not support routine comanagement of patients with the optometrists. American Optometric Association and American Academy of Optometry quickly responded in support of AAO and ASCRS. All four entities did not preclude legitimate and proper comanagement arrangements. Since that time, the pattern of practice has changed, requiring us to rethink our positions. This paper is written to provide a possible model for the ophthalmology-optometry practice management in ophthalmic surgeries including refractive surgery. Since the publication of the Joint Position Paper, the concept of comanagement has faded and a new model of integrated management has evolved. This has occurred as the changes in the employment pattern of the ophthalmic practice have incorporated optometrists into its fold. This evolution allowed ophthalmic and optometric community to co-exist and thrive to provide better patient care.

  10. Amniotic membrane allografts: development and clinical utility in ophthalmology

    Directory of Open Access Journals (Sweden)

    Rizzuti A

    2014-12-01

    Full Text Available Allison Rizzuti,1,2 Adam Goldenberg,1 Douglas R Lazzaro1,2 1SUNY Downstate Medical Center, 2Kings County Hospital Center, Brooklyn, NY, USA Abstract: Amniotic membrane, the innermost layer of the placenta, is a tissue that promotes epithelialization, while decreasing inflammation, neovascularization, and scarring. It is used in the surgical management of a wide variety of ophthalmic conditions where it functions as a graft or patch in ocular surface reconstruction. The development of new preservation techniques, as well as a sutureless amniotic membrane, has allowed for easier, in-office placement, without the disadvantages of an operating room procedure. The purpose of this review is to describe the historical development of amniotic membrane in ophthalmology and to describe its current clinical applications, particularly focusing on recent advances. Keywords: ocular surface, cornea, stem cells, prokera, allograft, patch, transplantation

  11. Gender differences in successful National Institutes of Health funding in ophthalmology.

    Science.gov (United States)

    Svider, Peter F; D'Aguillo, Christine M; White, Priscilla E; Pashkova, Anna A; Bhagat, Neelakshi; Langer, Paul D; Eloy, Jean Anderson

    2014-01-01

    To determine whether gender differences in individual National Institutes of Health (NIH) awards and in funding totals exist in ophthalmology, and to further characterize whether factors such as experience, academic rank, and terminal degree play a role. A retrospective review of awards granted to primary investigators (PIs) in ophthalmology departments from 2011 through the present was conducted. PIs were classified by gender, degree, experience, and academic position. The NIH funding database was used to gather award data. Academic medical center. Men had higher mean NIH awards ($418,605) than their female colleagues ($353,170; p = 0.005) and had higher total funding per PI (p = 0.004). Men had statistically higher awards at the level of assistant professor than their female counterparts (p careers, although this difference only reached statistical significance on comparison of faculty with 10 or fewer years of experience. Male PIs receiving grants since 2011 had higher awards than their female colleagues did, most markedly among PIs in the earlier portions of their career. Differences in gender representation among senior faculty and in positions of leadership in academic ophthalmology may be partially a result of disparities in research output, as scholarly productivity is an important component of the academic advancement process in ophthalmology. Copyright © 2014 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.

  12. Effectiveness of a 40-minute Ophthalmologic Examination Teaching Session on Medical Student Learning

    Directory of Open Access Journals (Sweden)

    Wirachin Hoonpongsimanont

    2015-10-01

    Full Text Available Introduction: Emergency physicians are among the few specialists besides ophthalmologists who commonly perform ophthalmologic examinations using the slit lamp and other instruments. However, most medical schools in the United States do not require an ophthalmology rotation upon completion. Teaching procedural skills to medical students can be challenging due to limited resources and instructor availability. Our study assesses the effectiveness of a 40-minute hands-on teaching session on ophthalmologic examination for medical students using only two instructors and low-cost equipment. Methods: We performed an interventional study using a convenience sample of subjects. Pre- and post-workshop questionnaires on students’ confidence in performing ophthalmologic examination were administered. We used a paired t-test and Wilcoxon rank test to analyze the data. Results: Of the 30 participants in the study, the mean age was 25 and the majority were first-year medical students. The students’ confidence in performing every portion of the ophthalmologic exam increased significantly after the teaching session. We found that the average confidence level before the teaching session were below 2 on a 1-5 Likert scale (1 being the least confident. Confidence levels in using the slit lamp had the highest improvement among the skills taught (2.17 95% CI [1.84-2.49]. Students reported the least improvement in their confidence in assessing extraocular movements (0.73, 95% CI [0.30-1.71] and examining pupillary function (0.73, 95% CI [0.42-1.04]. We observed the biggest difference in median confidence level in the use of the tonometer (4 with a p-value of <0.05. Conclusion: A 40-minute structured hands-on training session can significantly improve students’ confidence levels in ophthalmologic skills.

  13. COMPUTER LEARNING SIMULATOR WITH VIRTUAL REALITY FOR OPHTHALMOLOGY

    Directory of Open Access Journals (Sweden)

    Valeria V. Gribova

    2013-01-01

    Full Text Available A toolset of a medical computer learning simulator for ophthalmology with virtual reality and its implementation are considered in the paper. The simulator is oriented for professional skills training for students of medical universities. 

  14. Diagnostic accuracy of new imaging techniques in breast diseases

    Energy Technology Data Exchange (ETDEWEB)

    Gordenne, W; Bauduin, E [Liege Univ. (Belgium)

    1989-01-01

    During the last decade, the hypothetical carcinogenic effects of mammography have lead to new technical developments in X-ray diagnosis and to use of other imaging techniques such as ultrasonography (US), transillumination, magnetic resonance imaging (MRI). Many preliminary studies were published but few clinical trials are really convincing. According to the definition of a diagnostic tool, none of these new modalities is supposed to supplant mammography in the diagnosis of breast cancer. Improvements are expected by digital mammography in the near future. (Authors).

  15. Neuro-ophthalmological conditions: Study of the clinical care pathway.

    Science.gov (United States)

    Layat, I; Challe, G; LeHoang, P; Bodaghi, B; Touitou, V

    2017-06-01

    Neuro-ophthalmologic conditions require specialized multidisciplinary management, both medical and surgical, for patients affected by visual loss due to nervous system disease. The primary goal of this study is to define the specificity of neuro-ophthalmology within the realm of visual health. The secondary goal is to review clinical care pathways by studying the organization of management, in terms of accessibility to care and personalization of the care pathway. A field study was carried out from February to June 2015, within the ophthalmology service of the Pitié-Salpêtrière University Medical Center in Paris. A 30-minute interview with the patient before or after his or her neuro-ophthalmology consultation was performed, to describe the clinical care pathway. The medical records of interviewed patients were also analyzed. Seventeen care pathways (10 women and 7 men) were reviewed. The mean age at appearance of visual involvement was 44.5 years (±8.4 years). If we exclude 3 patients over 66 years and retired, 35.71% were active, 35.71% were disabled, and 28.57% were on sick leave. Ten patients (58.82%) met the criteria for admission to long-term care. The first step had been carried out by local private practitioners. The first physician seen was the general medicine physician (59%), then the private ophthalmologist on an emergency basis (17%). On average, patients went through 8 steps during their care pathway (from 6 to 10 steps) and 14 medical departments were involved. The study showed collaboration with the other services of the University Hospital Department of Vision and Disabilities (notably with the Fondation Rothschild, the Quinze-Vingts National Ophthalmology Hospital, and the Fondation Sainte-Marie). In addition to rehabilitation services, health care professionals participating in the outpatient care of the patients included an orthoptist (11.7%), a psychologist (11.7%), and an optician specializing in low vision for visual aids. Finally

  16. Vibration monitoring/diagnostic techniques, as applied to reactor coolant pumps

    International Nuclear Information System (INIS)

    Sculthorpe, B.R.; Johnson, K.M.

    1986-01-01

    With the increased awareness of reactor coolant pump (RCP) cracked shafts, brought about by the catastrophic shaft failure at Crystal River number3, Florida Power and Light Company, in conjunction with Bently Nevada Corporation, undertook a test program at St. Lucie Nuclear Unit number2, to confirm the integrity of all four RCP pump shafts. Reactor coolant pumps play a major roll in the operation of nuclear-powered generation facilities. The time required to disassemble and physically inspect a single RCP shaft would be lengthy, monetarily costly to the utility and its customers, and cause possible unnecessary man-rem exposure to plant personnel. When properly applied, vibration instrumentation can increase unit availability/reliability, as well as provide enhanced diagnostic capability. This paper reviews monitoring benefits and diagnostic techniques applicable to RCPs/motor drives

  17. Neuro-Ophthalmology at a Tertiary Eye Care Centre in India.

    Science.gov (United States)

    Dhiman, Rebika; Singh, Digvijay; Gantayala, Shiva P; Ganesan, Vaitheeswaran L; Sharma, Pradeep; Saxena, Rohit

    2017-11-09

    Neuro-ophthalmology as a specialty is underdeveloped in India. The aim of our study was to determine the spectrum and profile of patients presenting to a tertiary eye care center with neuro-ophthalmic disorders. A retrospective hospital-based study was conducted, and records of all patients seen at the neuro-ophthalmology clinic of Dr. Rajendra Prasad Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, New Delhi, India, over a 1-year period were retrieved and evaluated. Of a total of 30,111 patients referred to various specialty clinics in a span of 1 year, 1597 (5%) were referred for neuro-ophthalmology evaluation. The mean patient age was 30.8 ± 19.5 years, with a male dominance (M:F = 2.02:1). Among these patients, optic nerve disorders were noted in 63.8% (n = 1,020), cranial nerve palsy in 7% (n = 114), cortical visual impairment in 6.5% (n = 105), and others (eye/optic nerve hypophasia, blepharospasm, and optic disc drusen) in 6% (n = 95). Among the patients with optic nerve disorders, optic neuropathy without disc edema/(traumatic optic neuropathy, hereditary, tumor-related, retrobulbar neuritis, toxic, and idiopathic) was noted in 42.8% (n = 685) and optic neuropathy with disc edema (ischemic optic neuropathy, papilledema, post-papilledema optic atrophy, papillitis, neuroretinitis, and inflammatory optic neuropathy) in 20.9% (n = 335). Sixteen percent of patients (n = 263) were incorrect referrals. The neuro-ophthalmic clinic constitutes a significant referral unit in a tertiary eye care center in India. Traumatic and ischemic optic neuropathies are the most common diagnoses. Neuro-ophthalmology requires further development as a subspecialty in India to better serve the nation's population.

  18. Imaging mammary diagnostics. Diagnostic techniques, archetypical findings, differential diagnostcs and interventions. 2. rev. and enl. ed.

    International Nuclear Information System (INIS)

    Heywang-Koebrunner, S.; Schreer, I.

    2008-01-01

    The book includes the following chapters: I. Methodology: anamnesis and interview; clinical evidence, mammography, sonography, magnetic resonance tomography, new imaging techniques (scintigraphy, PET), transcutaneous biopsy, pre-operative marking; II. phenotypes: normal mammary glands, mastopathics, cysts, benign tumors, inflammatory diseases, in-situ carcinomas, invasive carcinomas, lymphomas, other semi-malign and malign tumors, post-traumatic, post-surgical and post-therapeutic changes, skin changes, male mamma, screening, continuative diagnostics of screening evidence and problem solving for symptomatic patients

  19. The influence on finite measurement accuracy on the SWE-to-PWE antenna diagnostics technique

    DEFF Research Database (Denmark)

    Cappellin, Cecilia; Breinbjerg, Olav; Frandsen, Aksel

    2006-01-01

    A new antenna diagnostics technique based on the transformation of the spherical wave expansion (SWE) into the plane wave expansion (PWE) is proposed. The new technique allows the recovery of the plane wave spectrum in the visible region, and in principle also in part of the invisible region, from...

  20. Application of smart phone on interactive teaching methods in ophthalmology

    Directory of Open Access Journals (Sweden)

    Xiao-Li Ma

    2016-06-01

    Full Text Available Smart phones as a symbol of the mobile Internet appears in college classroom, which is not only a challenge, but also a great opportunities of education information. This paper applied smart phones as the carrier of the "Internet" into ophthalmology classroom. Smart phones has a lot of features, such as rich teaching resources, diverse learning methods, flexible learning time, collating and recording capabilities and the timely, comprehensive and accurate teaching feedback so on, and could be used in case teaching and interactive teaching. The implementation of smart phones into ophthalmology classroom could inspire the learning enthusiasm of the students, enhance the quality of teaching, eventually improve teaching effects.

  1. Using Electronic Health Records to Build an Ophthalmologic Data Warehouse and Visualize Patients' Data.

    Science.gov (United States)

    Kortüm, Karsten U; Müller, Michael; Kern, Christoph; Babenko, Alexander; Mayer, Wolfgang J; Kampik, Anselm; Kreutzer, Thomas C; Priglinger, Siegfried; Hirneiss, Christoph

    2017-06-01

    To develop a near-real-time data warehouse (DW) in an academic ophthalmologic center to gain scientific use of increasing digital data from electronic medical records (EMR) and diagnostic devices. Database development. Specific macular clinic user interfaces within the institutional hospital information system were created. Orders for imaging modalities were sent by an EMR-linked picture-archiving and communications system to the respective devices. All data of 325 767 patients since 2002 were gathered in a DW running on an SQL database. A data discovery tool was developed. An exemplary search for patients with age-related macular degeneration, performed cataract surgery, and at least 10 intravitreal (excluding bevacizumab) injections was conducted. Data related to those patients (3 142 204 diagnoses [including diagnoses from other fields of medicine], 720 721 procedures [eg, surgery], and 45 416 intravitreal injections) were stored, including 81 274 optical coherence tomography measurements. A web-based browsing tool was successfully developed for data visualization and filtering data by several linked criteria, for example, minimum number of intravitreal injections of a specific drug and visual acuity interval. The exemplary search identified 450 patients with 516 eyes meeting all criteria. A DW was successfully implemented in an ophthalmologic academic environment to support and facilitate research by using increasing EMR and measurement data. The identification of eligible patients for studies was simplified. In future, software for decision support can be developed based on the DW and its structured data. The improved classification of diseases and semiautomatic validation of data via machine learning are warranted. Copyright © 2017 Elsevier Inc. All rights reserved.

  2. Encouraging Subspecialty Practice by Constructively Influencing Trainees Early in their Careers Will Improve Advocacy for Neuro-Ophthalmology among Nigerian Ophthalmologists

    Science.gov (United States)

    Ogun, Olufunmilola A.

    2016-01-01

    This study was conducted to assess the current knowledge, attitude, and perception of Nigerian ophthalmologists toward neuro-ophthalmology; identify barriers to the uptake of neuro-ophthalmology as a desired subspecialty; and make recommendations to improve interest in neuro-ophthalmology training. This was a cross-sectional survey of ophthalmology consultants and trainees from the six geopolitical zones of Nigeria, who were attending a national ophthalmology conference. All consenting respondents voluntarily completed a validated self-administered questionnaire. There were 107 respondents comprising 56 males and 51 females. Majority (54.2%) of respondents were aged 40 years and younger. Almost half (47.8%) worked at tertiary level, public health institutions. Only 10.3% worked in private practice. Neuro-ophthalmology exposure was short and occurred mainly during residency (65.7%), while 15% had no exposure at all. Most (80.4%) indicated only nominal interest in neuro-ophthalmology, while only 4.6% indicated a desire to specialize in the field. Financial constraint was the main obstacle to the pursuit of subspecialty training. A total of 86% of respondents admitted that full (34%) or partial (52%) Funding would motivate them to pursue the training. Among respondents desiring part sponsorship, more than half were willing to augment such sponsorship with personal funds. In conclusion, career interest in neuro-ophthalmology is very low among Nigerian ophthalmologists. Late and limited exposure to neuro-ophthalmology during medical training may be contributing factors. Early exposure to neuro-ophthalmology during medical school rotations, coupled with the provision of sponsored subspecialty training opportunities, will serve to increase enrollment in the field. PMID:29349319

  3. ICF implosion hotspot ion temperature diagnostic techniques based on neutron time-of-flight method

    International Nuclear Information System (INIS)

    Tang Qi; Song Zifeng; Chen Jiabin; Zhan Xiayu

    2013-01-01

    Ion temperature of implosion hotspot is a very important parameter for inertial confinement fusion. It reflects the energy level of the hotspot, and it is very sensitive to implosion symmetry and implosion speed. ICF implosion hotspot ion temperature diagnostic techniques based on neutron time-of-flight method were described. A neutron TOF spectrometer was developed using a ultrafast plastic scintillator as the neutron detector. Time response of the spectrometer has 1.1 ns FWHM and 0.5 ns rising time. TOF spectrum resolving method based on deconvolution and low pass filter was illuminated. Implosion hotspot ion temperature in low neutron yield and low ion temperature condition at Shenguang-Ⅲ facility was acquired using the diagnostic techniques. (authors)

  4. Electronic health record impact on productivity and efficiency in an academic pediatric ophthalmology practice.

    Science.gov (United States)

    Redd, Travis K; Read-Brown, Sarah; Choi, Dongseok; Yackel, Thomas R; Tu, Daniel C; Chiang, Michael F

    2014-12-01

    To measure the effect of electronic health record (EHR) implementation on productivity and efficiency in the pediatric ophthalmology division at an academic medical center. Four established providers were selected from the pediatric ophthalmology division at the Oregon Health & Science University Casey Eye Institute. Clinical volume was compared before and after EHR implementation for each provider. Time elapsed from chart open to completion (OTC time) and the proportion of charts completed during business hours were monitored for 3 years following implementation. Overall there was an 11% decrease in clinical volume following EHR implementation, which was not statistically significant (P = 0.18). The mean OTC time ranged from 5.5 to 28.3 hours among providers in this study, and trends over time were variable among the four providers. Forty-four percent of all charts were closed outside normal business hours (30% on weekdays, 14% on weekends). EHR implementation was associated with a negative impact on productivity and efficiency in our pediatric ophthalmology division. Copyright © 2014 American Association for Pediatric Ophthalmology and Strabismus. Published by Elsevier Inc. All rights reserved.

  5. Attitudes to research and research training among ophthalmologists and ophthalmology trainees in New Zealand.

    Science.gov (United States)

    Jayasundera, Thiran; Fisk, Michael; McGhee, Charles N J

    2003-08-01

    To determine the attitudes to research and research training among ophthalmologists and ophthalmology trainees in New Zealand. A structured, self-administered questionnaire was devised and after preliminary validation a postal survey was sent to all ophthalmologists and ophthalmology registrars and fellows in New Zealand. A total of 82 replies were received from 115 questionnaires sent out; a response rate of 71.3%. An overwhelming majority found research to have benefited their education, clinical practice and career; 67.1% of the respondents intended to do research in the future. Although a majority (56.4%) felt research to be beneficial to ophthalmology training, 42.3% felt research would be of limited or no benefit when selecting candidates for vocational training. However, 97.5% of respondents felt that ophthalmology trainees should undertake some form of research during training, with most supporting small studies or case reports (44.4%) or a short structured training course in research (42.0%). Interestingly, 86.6% felt that research methodology and data analysis should be taught in a structured fashion with most supporting courses or seminars of a few weeks duration during the vocational training period. Many ophthalmologists felt inadequately equipped or trained to mentor and supervise trainees undertaking research and 41.5% of consultant ophthalmologists felt further training to fulfil this role would be beneficial. This survey suggests that New Zealand ophthalmologists generally approve of and support a place for research, possibly of a more structured design, during ophthalmology training.

  6. [CME-certified online education in Germany - status in ophthalmology 2011].

    Science.gov (United States)

    Handzel, D M

    2012-06-01

    The use of the internet is becoming more and more important in every aspect of daily life, also in professional education. Online education and face-to-face learning have proven to be equally efficient. The aim of this study is to evaluate the amount of online education in the German-speaking internet 2011. The terms "ophthalmology", "online-education", "continuing medical education" and "CME" (partly in German language) were searched by an internet-search engine. The first 100 pages were visited. Pages were evaluated in respect of quality and quantity, authorship and possible influence of sponsors. Only 9 of the first 100 hits had an actual offer for ophthalmology. Nearly all of these were websites of ophthalmological scientific journals. The content represented the same educational format (pictures and text) as in the print issue. CME-certified online education can be found in Germany as offspring of print issues only. The content is identical with educational texts in the print issues. An enlargement of the offer, which uses the possibilities of modern internet technology is highly probable. This estimation is supported by the growing use of the internet and developments on English-speaking websites for online-education. © Georg Thieme Verlag KG Stuttgart · New York.

  7. Office-based deep sedation for pediatric ophthalmologic procedures using a sedation service model.

    Science.gov (United States)

    Lalwani, Kirk; Tomlinson, Matthew; Koh, Jeffrey; Wheeler, David

    2012-01-01

    Aims. (1) To assess the efficacy and safety of pediatric office-based sedation for ophthalmologic procedures using a pediatric sedation service model. (2) To assess the reduction in hospital charges of this model of care delivery compared to the operating room (OR) setting for similar procedures. Background. Sedation is used to facilitate pediatric procedures and to immobilize patients for imaging and examination. We believe that the pediatric sedation service model can be used to facilitate office-based deep sedation for brief ophthalmologic procedures and examinations. Methods. After IRB approval, all children who underwent office-based ophthalmologic procedures at our institution between January 1, 2000 and July 31, 2008 were identified using the sedation service database and the electronic health record. A comparison of hospital charges between similar procedures in the operating room was performed. Results. A total of 855 procedures were reviewed. Procedure completion rate was 100% (C.I. 99.62-100). There were no serious complications or unanticipated admissions. Our analysis showed a significant reduction in hospital charges (average of $1287 per patient) as a result of absent OR and recovery unit charges. Conclusions. Pediatric ophthalmologic minor procedures can be performed using a sedation service model with significant reductions in hospital charges.

  8. Office-Based Deep Sedation for Pediatric Ophthalmologic Procedures Using a Sedation Service Model

    Directory of Open Access Journals (Sweden)

    Kirk Lalwani

    2012-01-01

    Full Text Available Aims. (1 To assess the efficacy and safety of pediatric office-based sedation for ophthalmologic procedures using a pediatric sedation service model. (2 To assess the reduction in hospital charges of this model of care delivery compared to the operating room (OR setting for similar procedures. Background. Sedation is used to facilitate pediatric procedures and to immobilize patients for imaging and examination. We believe that the pediatric sedation service model can be used to facilitate office-based deep sedation for brief ophthalmologic procedures and examinations. Methods. After IRB approval, all children who underwent office-based ophthalmologic procedures at our institution between January 1, 2000 and July 31, 2008 were identified using the sedation service database and the electronic health record. A comparison of hospital charges between similar procedures in the operating room was performed. Results. A total of 855 procedures were reviewed. Procedure completion rate was 100% (C.I. 99.62–100. There were no serious complications or unanticipated admissions. Our analysis showed a significant reduction in hospital charges (average of $1287 per patient as a result of absent OR and recovery unit charges. Conclusions. Pediatric ophthalmologic minor procedures can be performed using a sedation service model with significant reductions in hospital charges.

  9. Alberto Urrets-Zavalía Jr (1920-2010): An Argentinian contributor to ophthalmology.

    Science.gov (United States)

    Grzybowski, Andrzej; Urrets-Zavalía, Julio A; Ascaso, Francisco J

    2016-05-01

    Alberto Urrets-Zavalía Jr was born in Córdoba (Argentina) in 1920. Chairman of the Department of Ophthalmology of the National University of Córdoba and founder of the Cornea and Glaucoma Surgical Center in the same city, in 1956 he created the first residency programme in Ophthalmology in his country. He founded the first Eye Bank and introduced one of the first argon laser photocoagulators in South America. He authored around 200 scientific presentations and publications, describing new findings and clinical entities. Thus, his individualisation of the cyclovertical component in strabismus contributed to important evolution of ideas concerning pathogenesis and therapy in oculomotor disorders of infancy. He was the first to propose the dehydration of the vitreous body in glaucoma patients before ocular surgery and developed a fixation pick and scleral depressor for retinal detachment surgery. He also described a new technique, the V-Z procedures for the correction of senile ectropion. In 1968, he published his Décollement de la rétine, considered a masterpiece in retinal detachment literature for many years. Urrets-Zavalía died in his native city at the age of 89. His prolific scientific and educational contributions make him one of the most brilliant and influential ophthalmologists of the 20th-century. © The Author(s) 2014.

  10. Plasma diagnostic techniques in thermal-barrier tandem-mirror fusion experiments

    International Nuclear Information System (INIS)

    Silver, E.H.; Clauser, J.F.; Carter, M.R.; Failor, B.H.; Foote, J.H.; Hornady, R.S.; James, R.A.; Lasnier, C.J.; Perkins, D.E.

    1986-01-01

    We review two classes of plasma diagnostic techniques used in thermal-barrier tandem-mirror fusion experiments. The emphasis of the first class is to study mirror-trapped electrons at the thermal-barrier location. The focus of the second class is to measure the spatial and temporal behavior of the plasma space potential at various axial locations. The design and operation of the instruments in these two categories are discussed and data that are representative of their performance is presented

  11. Laser diagnodent: a comparative study with other diagnostic techniques

    International Nuclear Information System (INIS)

    Godinho, Reugma Rego

    2002-01-01

    An evaluation of the Diagnodent equipment (Kavo Company, Germany) for the occlusal caries detection was dane through the comparison with other conventional diagnostic techniques, such as visual inspection, intra-oral micro camera and digital X-ray. The effectiveness of the equipment in the detection of hidden caries and its viability as a diagnosis method for caries in their initial stage was also studied. Fifty eight permanent molars and premolars teeth from patients with age between 6 and 30 years were studied. The obtained results indicated that the conventional methods employed for the caries diagnosis are unable to detect the carious lesion in its initial stage. The Diagnodent equipment has this capability to detect caries presenting a flawless surface, specially the hidden caries, allowing the dentist to decide between a preventive ar a conservative procedure. The main advantage of the Diagnodent is to be an objective method, compared to the visual and radiographic ones, that are dependent on the professional interpretation. The Diagnodent is, therefore, a promising alternative as an objective and standardized diagnosis method for the final diagnostic. (author)

  12. Imaging techniques used in the diagnostic workup of acute venous thromboembolic disease.

    Science.gov (United States)

    Tilve-Gómez, A; Rodríguez-Fernández, P; Trillo-Fandiño, L; Plasencia-Martínez, J M

    Early diagnosis is one of the most important factors affecting the prognosis of pulmonary embolism (PE); however, the clinical presentation of PE is often very unspecific and it can simulate other diseases. For these reasons, imaging tests, especially computed tomography angiography (CTA) of the pulmonary arteries, have become the keystone in the diagnostic workup of PE. The wide availability and high diagnostic performance of pulmonary CTA has led to an increase in the number of examinations done and a consequent increase in the population's exposure to radiation and iodinated contrast material. Thus, other techniques such as scintigraphy and venous ultrasonography of the lower limbs, although less accurate, continue to be used in certain circumstances, and optimized protocols have been developed for CTA to reduce the dose of radiation (by decreasing the kilovoltage) and the dose of contrast agents. We describe the technical characteristics and interpretation of the findings for each imaging technique used to diagnose PE and discuss their advantages and limitations; this knowledge will help the best technique to be chosen for each case. Finally, we comment on some data about the increased use of CTA, its clinical repercussions, its "overuse", and doubts about its cost-effectiveness. Copyright © 2016 SERAM. Publicado por Elsevier España, S.L.U. All rights reserved.

  13. Resonant laser techniques for combustion and flow diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Fritzon, Rolf

    1998-05-01

    This thesis presents results from two areas of research. Firstly, the resonant coherent laser techniques polarization spectroscopy (PS), degenerate four-wave mixing (DFWM) and stimulated emission (SE) have been developed in the general field of combustion diagnostics. Secondly, laser induced fluorescence (LIF) has been developed and applied for the visualization of mixture fractions in turbulent non reacting flows. PS was developed for instantaneous two-dimensional imaging of minor species in flames, the technique being demonstrated on OH and NO. Various aspects of imaging and of detection in general were investigated. Two-photon induced PS was demonstrated for the detection of NH{sub 3}, CO and N{sub 2} molecules. LIF was monitored simultaneously to allow a quantitative comparison between the techniques. Furthermore, PS and DFWM were developed for instantaneous two-dimensional OH temperature imaging. Through a novel experimental approach based on the use of a dual-wavelength dye laser and a diffraction grating the temperature imaging measurements were performed using only one laser and one CCD camera. A comparison between the two techniques was made. SE was through a crossed-beam arrangement developed for spatially resolved detection of flame species. Two-dimensional LIF was developed and applied for measuring mixture fractions in the shear layer between two co-flowing turbulent gaseous jets. The technique was further applied in a study of the mixing of a turbulent water jet impinging orthogonally onto a flat surface. Average concentration fields in the center-plane of the jet was compared with results from large eddy simulations and with data from the literature 221 refs, 48 figs, 5 tabs

  14. What is new in recommendations on ophthalmological screening in ...

    African Journals Online (AJOL)

    ... complication-toxic retinopathy. The present recommendations warn against making premature decision on medicine withdrawal, especially in the light of the most recent studies on their beneficial systemic influence. This paper systematizes the information on ophthalmological screening in chloroquine derivatives users.

  15. Career choices for ophthalmology made by newly qualified doctors in the United Kingdom, 1974–2005

    Directory of Open Access Journals (Sweden)

    Goldacre Michael J

    2008-03-01

    Full Text Available Abstract Background The paper aims to report trends in career choices for ophthalmology among UK medical graduates. Methods Postal questionnaire surveys were undertaken of qualifiers from all UK medical schools in nine qualification years since 1974. Data were analysed by univariate cross-tabulation. The significance of comparisons between groups of doctors were calculated by the use of chi-squared tests and adjusted residuals. Results Ophthalmology was the first choice of long term career for 2.3% of men and 1.5% of women one year after qualification; 2.0% of men and 1.4% of women three years after; and 1.8% of men and 1.2% of women at five years. Comparing early choices with eventual destinations, 64% who chose ophthalmology in year one, 84% in year three, and 92% in year five eventually practised in the specialty. The concordance between year one choice and eventual destination was higher for ophthalmology than for most other specialties. 'Enthusiasm for and commitment to the specialty' was the most important single factor in influencing career choice. The prospect of good working hours and conditions was also an important influence: it influenced career choice a great deal for a higher percentage of those who chose ophthalmology (66% in the third year than those who made other surgical choices (23%. Conclusion Those choosing ophthalmology show a high level of commitment to it. Their commitment is strengthened by the prospect of attractive hours and working conditions. Many doctors who become ophthalmologists have already made their choice by the end of their first post-qualification year.

  16. Image analysis in modern ophthalmology: from acquisition to computer assisted diagnosis and telemedicine

    Science.gov (United States)

    Marrugo, Andrés G.; Millán, María S.; Cristóbal, Gabriel; Gabarda, Salvador; Sorel, Michal; Sroubek, Filip

    2012-06-01

    Medical digital imaging has become a key element of modern health care procedures. It provides visual documentation and a permanent record for the patients, and most important the ability to extract information about many diseases. Modern ophthalmology thrives and develops on the advances in digital imaging and computing power. In this work we present an overview of recent image processing techniques proposed by the authors in the area of digital eye fundus photography. Our applications range from retinal image quality assessment to image restoration via blind deconvolution and visualization of structural changes in time between patient visits. All proposed within a framework for improving and assisting the medical practice and the forthcoming scenario of the information chain in telemedicine.

  17. Experiences with E-learning in Ophthalmology

    OpenAIRE

    Seema Dutt Bandhu; Swati Raje

    2014-01-01

    Introduction: E-learning is the use of internet for the purpose of education. E-learning in medical education is at a nascent stage in our country. The present study was carried out with the purpose of introducing e-learning to third year medical students in the subject of Ophthalmology and taking feedback on their attitude towards the new methodology of teaching and evaluating. Materials and Methods: E-learning was introduced to the seventh semester students of MBBS in the subject of Ophthal...

  18. MR cholangiopancreatography: prospective comparison of a breath-hold 2D projection technique with diagnostic ERCP

    International Nuclear Information System (INIS)

    Lomas, D.J.; Bearcroft, P.W.P.; Gimson, A.E.

    1999-01-01

    The aim of this study was to compare prospectively a breath-hold projection magnetic resonance cholangiopancreatography (MRCP) technique with diagnostic endoscopic retrograde cholangiopancreatography (ERCP). Seventy-six patients with suspected strictures or choledocholithiasis were referred for MRCP and subsequent ERCP examination, which were performed within 4 h of each other. The MRCP technique was performed using fat-suppressed rapid acquisition with relaxation enhancement (RARE) projection images obtained in standardised planes with additional targeted projections as required by the supervising radiologist. Two radiologists (in consensus) assessed the MRCP results prospectively and independently for the presence of bile duct calculi, strictures, non-specific biliary dilatation and pancreatic duct dilatation, and recorded a single primary diagnosis. The ERCP was assessed prospectively and independently by a single endoscopist and used as a gold standard for comparison with MRCP. Diagnostic agreement was assessed by the Kappa statistic. The MRCP technique failed in two patients and ERCP in five. In the remaining 69 referrals ERCP demonstrated normal findings in 23 cases, strictures in 19 cases, choledocholithiasis in 9 cases, non-specific biliary dilatation in 14 cases and chronic pancreatitis in 4 cases. The MRCP technique correctly demonstrated 22 of 23 normal cases, 19 strictures with one false positive (sensitivity 100 %, specificity 98 %), all 9 cases of choledocholithiasis with two false positives (sensitivity 100 %, specificity 97 %), 12 of 14 cases of non-specific biliary dilatation and only 1 of 4 cases of chronic pancreatitis. There was overall good agreement for diagnosis based on a kappa value of 0.88. Breath-hold projection MRCP can provide non-invasively comparable diagnostic information to diagnostic ERCP for suspected choledocholithiasis and biliary strictures and may allow more selective use of therapeutic ERCP. (orig.)

  19. Optimized design of shields for diagnostic X rays with NCRP 147 technique

    International Nuclear Information System (INIS)

    Gama T, G.

    2006-01-01

    A comparison among the design techniques of shielding for X-ray diagnostic rooms with the NCRP 49 (1976) report technique, AAPM 39 (1993) Y the one of the NCRP 147 (2005) technique. The designs correspond to a room of conventional X-rays, one of fluoroscopy, one of tomography Y one of mammography. In all the cases it demonstrates that the NCRP 49 technique overestimate the shieldings. The causes of the overestimation of the NCRP 49 can be attributed to: a) high values of the work charge that don't consider the spectral fluence of the photons that are present in each room, b) to the differences in the values of the kerma in air without attenuation for the dispersed primary radiation Y of leakage among both reports. (Author)

  20. Development of technique for diagnostics of social reserves of development of collective labour potential

    OpenAIRE

    Голубєв, Станіслав Миколайович

    2015-01-01

    The problems of diagnostics of social reserves of the collective labour potential are considered in the article. The aim of this study is to develop diagnostic techniques of social reserves of the collective labour potential in the work and the essence of the concept of "social reserves" as a subject of study of economics and their features in the study of collective labour potential. The use of these reserves can increase the efficiency of the labour collective processes by improving coopera...

  1. Analysis of online patient education materials in pediatric ophthalmology.

    Science.gov (United States)

    John, Ann M; John, Elizabeth S; Hansberry, David R; Thomas, Prashant J; Guo, Suqin

    2015-10-01

    Patients increasingly consult online resources for healthcare information. The American Medical Association (AMA) and National Institutes of Health (NIH) recommend that online education resources be written between a 3rd- and 7th-grade level. This study assesses whether online health information abides by these guidelines. Ten pediatric ophthalmology conditions were entered into a commonly used search engine, Google.com, and analyzed using 10 validated readability scales. Scientific articles and articles written on patient forums were excluded. The 10 conditions--amblyopia, cataract, conjunctivitis, corneal abrasion, nystagmus, retinoblastoma, retinopathy of prematurity, strabismus, stye, and glaucoma--were also searched and analyzed separately from widely used websites, including Wikipedia and WebMD, as well as those of professional societies, including the American Association for Pediatric Ophthalmology and Strabismus (AAPOS) and the American Optometric Association (AOA). The majority of articles were written above recommended guidelines. All scales showed that the 100 articles were written at a mean grade-level of 11.75 ± 2.72. Only 12% of articles were written below a 9th-grade level and only 3% met recommended criteria. The articles accrued separately from Wikipedia, WebMD, AAPOS, and AOA also had average grade levels above the recommended guidelines. The readability of online patient education material exceeds NIH and AMA guidelines. This disparity can adversely affect caregiver comprehension of such resources and contribute to poor decision making. Pediatric ophthalmology online articles are generally written at a level too high for average caregiver comprehension. Revision of articles can increase satisfaction, improve outcomes, and facilitate the patient-ophthalmologist relationship. Published by Elsevier Inc.

  2. New perineal injection technique for pudendal nerve infiltration in diagnostic and therapeutic procedures

    NARCIS (Netherlands)

    Weinschenk, Stefan; Hollmann, Markus W.; Strowitzki, Thomas

    2016-01-01

    Pudendal nerve injection is used as a diagnostic procedure in the vulvar region and for therapeutic purposes, such as in vulvodynia. Here, we provide a new, easy-to-perform perineal injection technique. We analyzed 105 perineal injections into the pudendal nerve with a local anesthetic (LA),

  3. Ophthalmology's future in the next decade: a historical and comparative perspective.

    Science.gov (United States)

    Day, S H

    1999-01-01

    To gain a historical and comparative perspective about the future of ophthalmology within the profession of medicine. A literature search is made of disciplines other than medicine (history, sociology, philosophy, economics, and ethics) in order to assess factors responsible for survival and healthiness of a profession. The "learned" professions (medicine, law, and theology) are assessed. Other "professional" careers valued by society (sports and classical music) are reviewed. From the perspective of other disciplines, the future of ophthalmology is seen as vulnerable and fragile. Survival of professions, be they classically or economically defined, is linked to societal needs, a profession's unique commitment and ability to provide services to society, and the profession's maintenance of knowledge as well as skill-based services. Historical evidence has shown erosion of a profession's power consequent to capitalist influences, government influences, access of skills by less trained individuals, and elitist posturing by a profession. Comparative evidence has shown societal acceptance of an escalation of salaries for designated superstars, increasing roles and influence of managerial personnel, and trivialization of values other than economic ones. Attention to historical and comparative trends by individual ophthalmologists as well as associations representing ophthalmologists is mandatory if ophthalmology as we know it is to survive within the profession of medicine.

  4. Ophthalmological evolution in hyperthyroid patients treated with radioactive iodine

    International Nuclear Information System (INIS)

    Marrero Rodriguez, Maria Teresa; Rodriguez Gonzalez, Julio Cesar; Alavez Martin, Ernesto

    2005-01-01

    This study was aimed at analyzing the ophthalmological evolution in hyperthyroid patients treated with radioactive iodine. 100 patients (88 females and 12 males) from the thyroid department of the National Institute of Endocrinology with clinical and biochemical diagnosis of hyperthyroidism and with a mean age of 40 + - 10 years old, were studied. These patients underwent a treatment with radioactive iodine at a dose of 80 m Ci/g of thyroid tissue. A bilateral ophthalmometry was performed to each patient before the treatment and 12 months after it. Mean ophthalmometry of the right eye was 14.51 + - 2.86 mm before the treatment and 13.92 + - 2.83 mm after the treatment, whereas for the left eye it was 14.98 + - 2.91 mm and 14.27 + - 2.83 mm , respectively. Taking into account the results of the ophthalmometry, we concluded that the use of radioactive iodine in the treatment of hyperthyroid patients had no negative results on the ophthalmological evolution of the studied patients

  5. PREFACE: IX International Conference on Modern Techniques of Plasma Diagnostics and their Application

    Science.gov (United States)

    Savjolov, A. S.; Dodulad, E. I.

    2016-01-01

    The IX Conference on ''Modern Techniques of Plasma Diagnosis and their Application'' was held on 5 - 7 November, 2014 at National Research Nuclear University MEPhI (NRNU MEPhI). The goal of the conference was an exchange of information on both high-temperature and low-temperature plasma diagnostics as well as deliberation and analysis of various diagnostic techniques and their applicability in science, industry, ecology, medicine and other fields. The Conference also provided young scientists from scientific centres and universities engaged in plasma diagnostics with an opportunity to attend the lectures given by the leading specialists in this field as well as present their own results and findings. The first workshop titled ''Modern problems of plasma diagnostics and their application for control of chemicals and the environment'' took place at Moscow Engineering and Physics Institute (MEPhI) in June 1998 with the support of the Section on Diagnostics of the Council of Russian Academic of Science on Plasma Physics and since then these forums have been held at MEPhI every two years. In 2008 the workshop was assigned a conference status. More than 150 specialists on plasma diagnostics and students took part in the last conference. They represented leading Russian scientific centres (such as Troitsk Institute of Innovative and Thermonuclear Research, National Research Centre ''Kurchatov Institute'', Russian Federal Nuclear Centre - All-Russian Scientific Research Institute of Experimental Physics and others) and universities from Belarus, Ukraine, Germany, USA, Belgium and Sweden. About 30 reports were made by young researchers, students and post-graduate students. All presentations during the conference were broadcasted online over the internet with viewers in Moscow, Prague, St. Petersburgh and other cities. The Conference was held within the framework of the Centre of Plasma, Laser Research and Technology supported by MEPhI Academic Excellence Project (Russian

  6. Facing the challenges in ophthalmology clerkship teaching: Is flipped classroom the answer?

    Directory of Open Access Journals (Sweden)

    Ying Lin

    Full Text Available Recent reform of medical education highlights the growing concerns about the capability of the current educational model to equip medical school students with essential skills for future career development. In the field of ophthalmology, although many attempts have been made to address the problem of the decreasing teaching time and the increasing load of course content, a growing body of literature indicates the need to reform the current ophthalmology teaching strategies. Flipped classroom is a new pedagogical model in which students develop a basic understanding of the course materials before class, and use in-class time for learner-centered activities, such as group discussion and presentation. However, few studies have evaluated the effectiveness of the flipped classroom in ophthalmology education. This study, for the first time, assesses the use of flipped classroom in ophthalmology, specifically glaucoma and ocular trauma clerkship teaching. A total number of 44 international medical school students from diverse background were enrolled in this study, and randomly divided into two groups. One group took the flipped glaucoma classroom and lecture-based ocular trauma classroom, while the other group took the flipped ocular trauma classroom and lecture-based glaucoma classroom. In the traditional lecture-based classroom, students attended the didactic lecture and did the homework after class. In the flipped classroom, students were asked to watch the prerecorded lectures before the class, and use the class time for homework discussion. Both the teachers and students were asked to complete feedback questionnaires after the classroom. We found that the two groups did not show differences in the final exam scores. However, the flipped classroom helped students to develop skills in problem solving, creative thinking and team working. Also, compared to the lecture-based classroom, both teachers and students were more satisfied with the flipped

  7. Facing the challenges in ophthalmology clerkship teaching: Is flipped classroom the answer?

    Science.gov (United States)

    Lin, Ying; Zhu, Yi; Chen, Chuan; Wang, Wei; Chen, Tingting; Li, Tao; Li, Yonghao; Liu, Bingqian; Lian, Yu; Lu, Lin; Zou, Yuxian; Liu, Yizhi

    2017-01-01

    Recent reform of medical education highlights the growing concerns about the capability of the current educational model to equip medical school students with essential skills for future career development. In the field of ophthalmology, although many attempts have been made to address the problem of the decreasing teaching time and the increasing load of course content, a growing body of literature indicates the need to reform the current ophthalmology teaching strategies. Flipped classroom is a new pedagogical model in which students develop a basic understanding of the course materials before class, and use in-class time for learner-centered activities, such as group discussion and presentation. However, few studies have evaluated the effectiveness of the flipped classroom in ophthalmology education. This study, for the first time, assesses the use of flipped classroom in ophthalmology, specifically glaucoma and ocular trauma clerkship teaching. A total number of 44 international medical school students from diverse background were enrolled in this study, and randomly divided into two groups. One group took the flipped glaucoma classroom and lecture-based ocular trauma classroom, while the other group took the flipped ocular trauma classroom and lecture-based glaucoma classroom. In the traditional lecture-based classroom, students attended the didactic lecture and did the homework after class. In the flipped classroom, students were asked to watch the prerecorded lectures before the class, and use the class time for homework discussion. Both the teachers and students were asked to complete feedback questionnaires after the classroom. We found that the two groups did not show differences in the final exam scores. However, the flipped classroom helped students to develop skills in problem solving, creative thinking and team working. Also, compared to the lecture-based classroom, both teachers and students were more satisfied with the flipped classroom

  8. [Essential aspects of ophthalmological expert assessment in private accident insurance].

    Science.gov (United States)

    Tost, F

    2014-06-01

    Commissions for an expert assessment place basically high demands on commissioned eye specialists because this activity differs from the normal routine field of work. In addition to assessing objective symptoms and subjective symptomatics in a special analytical manner, eye specialists are expected to have knowledge of basic legal terminology, such as proximate cause, evidence and evidential value. Only under these prerequisites can an ophthalmologist fulfill the function of an expert with a high level of quality and adequately adjust the special medical ophthalmological expertise to the requirements of the predominantly legally based clients commissioning the report and oriented to the appropriate valid legal norms. Particularly common difficulties associated with making an ophthalmological expert report for private accident insurance, e.g. determination of the reduction in functional quality, consideration of partial causality and assessment of diplopia are discussed.

  9. P3-1: Ophthalmologic Factors Influencing Asthenopia with Watching 3D Displays

    Directory of Open Access Journals (Sweden)

    Sungwook Wee

    2012-10-01

    Full Text Available Purpose: To identify ophthalmologic factors influencing asthenopia while watching 3D displays. Methods: 30 adult subjects without ophthalmologic abnormality watched the same 3D displays for 30 minutes. Each subject's far and near visual acuity, near points of accommodation and convergence, amplitude of fusional convergence and divergence, stereopsis, angle of phoric deviation, tear break-up time, and temperature of ocular surface before and after watching 3D displays were measured. And surveys for subjective symptoms right after watching 3D displays were conducted. The above-mentioned experiments were performed equally with 2D displays for detection of innate influence of 3D displays. Results: The near points of accommodation and convergence were significantly changed after watching 3D displays (p < .05 compared to 2D displays. And all 10 subjective symptoms were significantly increased after watching 3D displays (p < .05. Conclusion: The accommodation and binocular vergence are predominant ophthalmologic factors that might influence asthenopia significantly while watching 3D displays. Subjective visual discomfort significantly increases with watching 3D displays, and more specific evaluation should be added for detecting the practically related factors with asthenopia.

  10. [Evaluation of Web-based software applications for administrating and organising an ophthalmological clinical trial site].

    Science.gov (United States)

    Kortüm, K; Reznicek, L; Leicht, S; Ulbig, M; Wolf, A

    2013-07-01

    The importance and complexity of clinical trials is continuously increasing, especially in innovative specialties like ophthalmology. Therefore an efficient clinical trial site organisational structure is essential. In modern internet times, this can be accomplished by web-based applications. In total, 3 software applications (Vibe on Prem, Sharepoint and open source software) were evaluated in a clinical trial site in ophthalmology. Assessment criteria were set; they were: reliability, easiness of administration, usability, scheduling, task list, knowledge management, operating costs and worldwide availability. Vibe on Prem customised by the local university met the assessment criteria best. Other applications were not as strong. By introducing a web-based application for administrating and organising an ophthalmological trial site, studies can be conducted in a more efficient and reliable manner. Georg Thieme Verlag KG Stuttgart · New York.

  11. Usefulness of post-mortem ophthalmological endoscopy during forensic autopsy: a case report.

    Science.gov (United States)

    Tsujinaka, Masatake; Akaza, Kayoko; Nagai, Atsushi; Nakamura, Isao; Bunai, Yasuo

    2005-01-01

    Post-mortem intraocular findings in two autopsy cases with traumatic intracranial haemorrhage were obtained using an ophthalmological endoscope. The endoscopy results clearly revealed the presence of intraocular haemorrhages and papilledema caused by intracranial haemorrhage. Post-mortem ophthalmological endoscopy offers several benefits. First, post-mortem intraocular findings can be directly observed in corpses with post-mortem clouding of the cornea. Secondly, the endoscopy only requires a 0.9 mm incision in the sclera and does not require the removal of the eye from the corpse, a procedure that should be avoided for ethical and cosmetic reasons. Thus, post-mortem opthalmological endoscopy is a useful method for obtaining intraocular findings in autopsies.

  12. Diagnostic techniques

    International Nuclear Information System (INIS)

    Berquist, T.H.; Bender, C.E.; James, E.M.; Brown, M.L.; McLeod, R.A.; Broderick, D.F.; Welch, T.J.

    1989-01-01

    Proper application of imaging procedures is essential to obtain needed information for diagnosis and therapy planning in patients with suspected foot and/or ankle pathology. This paper provides basic background data for the numerous imaging techniques

  13. The impact of the economy and recessions on the marketplace demand for ophthalmologists (an American Ophthalmological Society thesis).

    Science.gov (United States)

    Adelman, Ron A; Nwanze, Chukwuemeka C

    2011-12-01

    To develop a help-wanted index (HWI) to measure trends in marketplace demand for ophthalmologists, to identify the economic drivers of demand, and to determine the impact of economic recessions on the ophthalmology job market. Review of physician recruitment advertisements appearing in the journals Ophthalmology, American Journal of Ophthalmology, and Archives of Ophthalmology from January 1980 through June 2006. Over the 26-year study period a consistent increase in the demand for subspecialists (31% of HWI in 1980 to 80% in 2005) was noted. There was also an increase in the demand for academic ophthalmologists. The need for academic ophthalmologists seems to be correlated with national research expenditure and stock market gains (P = .00191), whereas demand for private practice ophthalmologists seems to be correlated with the national economic well-being, as measured by gross domestic product (GDP) (P market gains, GDP, and discretionary health care expenditure have been associated with the ophthalmology job market. These factors tend to decline with economic recessions. Historically, the demand for ophthalmologists has declined 2 to 3 years following a recession, which may mean lower demand in the near future, given the recent recession.

  14. Measuring the perceived quality of ophthalmology services in private organizations. A marketing perspective

    Science.gov (United States)

    Gheorghe, Iuliana Raluca; Gheorghe, Consuela-Mădălina; Purcărea, Victor Lorin

    2018-01-01

    Nowadays, the competition registered on the Romanian markets regarding the activity of private ophthalmology organizations has raised their interest in developing consumer-oriented strategies. The key factor that assures a differentiation as well as a competitive advantage is the service quality from a marketing perspective. Objectives: From a marketing perspective, service quality is measured as a perceived discrepancy between the consumers’ expectations and was actually performed in health care services. The most widely and validated measurement is the SERVQUAL scale. However, a variety of SERVQUAL scales have been applied in different health care environments without taking into consideration the specialty of the health care service. Thus, the objective of this paper was to measure the service quality in the Romanian ophthalmology private organizations using the SERVQUAL measurement, by identifying the SERVQUAL dimensions, which register the highest and the lowest gap scores. Materials and methods: The instrument for data collection was the SERVQUAL self-administered questionnaire that consisted of 22 items measured on a 5-point Likert scale. The sample size encompassed 100 participants and the sampling technique was the snowball. The internal consistency, validity and the reliability of the SERVQUAL scale was determined by the Cronbach’s alpha coefficients and factor analysis. The SERVQUAL questionnaire focused on 5 dimensions (tangibles, reliability, assurance, empathy and responsiveness) and each dimension, in its turn, was characterized by different items. Results: The mean age of the participants was 49.52 years, with a mean income of 3031 Romanian Currency and the mean period of wearing eyeglasses was 5 years (±2). Further, there were 47% females and 53% males. The overall internal consistency of the SERVQUAL scale, as well as the dimensions’ internal consistency were all above 0.7 and the factor analysis revealed that the items loaded properly on

  15. Measuring the perceived quality of ophthalmology services in private organizations. A marketing perspective.

    Science.gov (United States)

    Gheorghe, Iuliana Raluca; Gheorghe, Consuela-Mădălina; Purcărea, Victor Lorin

    2018-01-01

    Nowadays, the competition registered on the Romanian markets regarding the activity of private ophthalmology organizations has raised their interest in developing consumer-oriented strategies. The key factor that assures a differentiation as well as a competitive advantage is the service quality from a marketing perspective. From a marketing perspective, service quality is measured as a perceived discrepancy between the consumers' expectations and was actually performed in health care services. The most widely and validated measurement is the SERVQUAL scale. However, a variety of SERVQUAL scales have been applied in different health care environments without taking into consideration the specialty of the health care service. Thus, the objective of this paper was to measure the service quality in the Romanian ophthalmology private organizations using the SERVQUAL measurement, by identifying the SERVQUAL dimensions, which register the highest and the lowest gap scores. The instrument for data collection was the SERVQUAL self-administered questionnaire that consisted of 22 items measured on a 5-point Likert scale. The sample size encompassed 100 participants and the sampling technique was the snowball. The internal consistency, validity and the reliability of the SERVQUAL scale was determined by the Cronbach's alpha coefficients and factor analysis. The SERVQUAL questionnaire focused on 5 dimensions (tangibles, reliability, assurance, empathy and responsiveness) and each dimension, in its turn, was characterized by different items. The mean age of the participants was 49.52 years, with a mean income of 3031 Romanian Currency and the mean period of wearing eyeglasses was 5 years (±2). Further, there were 47% females and 53% males. The overall internal consistency of the SERVQUAL scale, as well as the dimensions' internal consistency were all above 0.7 and the factor analysis revealed that the items loaded properly on each dimension. Moreover, the gap scores of the

  16. Toward computer-assisted diagnosis and telemedicine in ophthalmology

    Czech Academy of Sciences Publication Activity Database

    Marrugo, A.; Millán, M. S.; Cristóbal, G.; Gabarda, S.; Šorel, Michal; Šroubek, Filip

    2012-01-01

    Roč. 2012, č. 6 (2012), s. 1-3 ISSN 1818-2259 R&D Projects: GA MŠk 1M0572 Institutional research plan: CEZ:AV0Z10750506 Institutional support: RVO:67985556 Keywords : computer-aided diagnosis * medical and retinal image * deconvolution * telemedicine Subject RIV: JD - Computer Applications, Robotics http://library.utia.cas.cz/separaty/2012/ZOI/sorel-toward computer-assisted diagnosis and telemedicine in ophthalmology.pdf

  17. [Clinical and therapeutic differences in neuro-ophthalmological involvement secondary to syphilis].

    Science.gov (United States)

    Crespo-Burillo, J A; Gil-Perez, D; Alarcia-Alejos, R; Hernando-Quintana, N; Garcia-Rubio, S; Martin-Martinez, J

    2014-09-16

    INTRODUCTION. There are many forms of neuro-ophthalmological involvement secondary to syphilis, and not all of them are well known. Our aim is to determine the clinical and therapeutic differences in these patients. CASE REPORTS. Our sample included eight patients diagnosed with an ocular and neuro-ophthalmological disorder due to syphilis over the years 2012 and 2013. Five of them presented uveitis, pan-eveitis being the most frequent, with three cases. Two cases presented papilloedema and another displayed retrobulbar optic neuropathy. A total of 62.5% were diagnosed with neurosyphilis, the presence of which was related with compromise of the optic nerve (p = 0.035). None of them gave positive for VDRL in cerebrospinal fluid and they were diagnosed by the presence of FTA antibodies together with high protein levels in cerebrospinal fluid, lymphocytic pleocytosis or intrathecal synthesis of antibodies. In the absence of uveitis, diagnosis was delayed by a mean time of 2.6 months (p = 0.047). All the patients, except one who required a vitrectomy, progressed favourably with intravenous antibiotic therapy. CONCLUSIONS. In cases of neuro-ophthalmological compromise, whether inflammatory or non-inflammatory, the physician must bear syphilis in mind as a potential causation in order to avoid delays in the diagnosis, since early well-tailored treatment can prevent permanent loss of sight.

  18. Experiences with E-learning in Ophthalmology

    Directory of Open Access Journals (Sweden)

    Seema Dutt Bandhu

    2014-01-01

    Full Text Available Introduction: E-learning is the use of internet for the purpose of education. E-learning in medical education is at a nascent stage in our country. The present study was carried out with the purpose of introducing e-learning to third year medical students in the subject of Ophthalmology and taking feedback on their attitude towards the new methodology of teaching and evaluating. Materials and Methods: E-learning was introduced to the seventh semester students of MBBS in the subject of Ophthalmology. The topics were converted to web friendly format and used for teaching and evaluating. Feedback was taken from the students on completion of the term on their attitudes towards e-learning and their views on the scope of e-learning in medical education. Results: All the students agreed on the usefulness of e-learning in medical education. Eleven students (27.5% found the medium of e-learning to be interesting, 15 (37.5% considered it to be easy and accessible, 10 (25% found it to be fast and easy, 4 (10% considered it to be a medium which can give updated information. Twenty-three (57.5% students considered that e-learning should be a medium of instruction in all the subjects, 15 (37.5% students considered its usefulness in clinical subjects only. Twenty-eight students (70% desired that e-learning should be used to provide important notes, questions, MCQs on all topics. Conclusions: E-learning is well accepted as a medium of instruction by medical students.

  19. A comparison of analogue and digital techniques in upper gastrointestinal examinations: absorbed dose and diagnostic quality of the images

    Energy Technology Data Exchange (ETDEWEB)

    Axelsson, B.; Hansson, I.B. [Department of Hospital Physics, Karolinska Hospital, Stockholm (Sweden); Boden, K.; Witt, H.H. [Department of Diagnostic Radiology, Karolinska Hospital, Stockholm (Sweden); Fransson, S.G. [Department of Thoracic Radiology, University Hospital, Linkoeping (Sweden); Persliden, J. [Department of Radiation Physics, University Hospital, Linkoeping (Sweden)

    2000-08-01

    This study was performed to investigate whether patient exposure and diagnostic quality of the image is significantly influenced by the introduction of digital image acquisition techniques. Evaluation was performed for three different techniques (analogue, analogue fluoro+digital radiography, digital) in examination of the upper gastrointestinal tract. The evaluation was done from data acquired in three different departments. Patient exposure was recorded as KERMA-area product (KAP) and the individual patient readings were normalised to a standard size patient. Image quality was assessed using visual grading with a reference image. The recorded KAP values were significantly higher (22.3 Gycm{sup 2}) for the fully digital technique compared to the others (analogue 6.8 Gycm{sup 2}, analogue+digital 3.6 Gycm{sup 2}). This was due mostly to an increased number of exposures. The diagnostic quality of the image was, however, also regarded to be slightly lower for the technique giving the lowest patient dose with the smallest number of exposures (analogue+digital). The digital examination technique, as used in this study, thus resulted in significantly higher patient dose without any significant gain in diagnostic quality of the image. (orig.)

  20. A comparison of analogue and digital techniques in upper gastrointestinal examinations: absorbed dose and diagnostic quality of the images

    International Nuclear Information System (INIS)

    Axelsson, B.; Hansson, I.B.; Boden, K.; Witt, H.H.; Fransson, S.G.; Persliden, J.

    2000-01-01

    This study was performed to investigate whether patient exposure and diagnostic quality of the image is significantly influenced by the introduction of digital image acquisition techniques. Evaluation was performed for three different techniques (analogue, analogue fluoro+digital radiography, digital) in examination of the upper gastrointestinal tract. The evaluation was done from data acquired in three different departments. Patient exposure was recorded as KERMA-area product (KAP) and the individual patient readings were normalised to a standard size patient. Image quality was assessed using visual grading with a reference image. The recorded KAP values were significantly higher (22.3 Gycm 2 ) for the fully digital technique compared to the others (analogue 6.8 Gycm 2 , analogue+digital 3.6 Gycm 2 ). This was due mostly to an increased number of exposures. The diagnostic quality of the image was, however, also regarded to be slightly lower for the technique giving the lowest patient dose with the smallest number of exposures (analogue+digital). The digital examination technique, as used in this study, thus resulted in significantly higher patient dose without any significant gain in diagnostic quality of the image. (orig.)

  1. Ophthalmology programs at ABCC. A brief review and preliminary plan

    Energy Technology Data Exchange (ETDEWEB)

    Finch, S C; Jablon, S

    1961-07-19

    A proposal is made for a continuing ophthalmology program for exposed and control subjects at Nagasaki and Hiroshima. This program is based on a fixed population selected from the PE-86 and the ME-200 Adult Health Study samples. 27 references, 4 tables.

  2. Risk of bias assessment of randomised controlled trials in high-impact ophthalmology journals and general medical journals: a systematic review.

    Science.gov (United States)

    Joksimovic, Lazar; Koucheki, Robert; Popovic, Marko; Ahmed, Yusuf; Schlenker, Matthew B; Ahmed, Iqbal Ike K

    2017-10-01

    Evidence-based treatments in ophthalmology are often based on the results of randomised controlled trials. Biased conclusions from randomised controlled trials may lead to inappropriate management recommendations. This systematic review investigates the prevalence of bias risk in randomised controlled trials published in high-impact ophthalmology journals and ophthalmology trials from general medical journals. Using Ovid MEDLINE, randomised controlled trials in the top 10 high-impact ophthalmology journals in 2015 were systematically identified and critically appraised for the prevalence of bias risk. Included randomised controlled trials were assessed in all domains of bias as defined by the Cochrane Collaboration. In addition, the prevalence of conflict of interest and industry sponsorship was investigated. A comparison with ophthalmology articles from high-impact general medical journals was performed. Of the 259 records that were screened from ophthalmology-specific journals, 119 trials met all inclusion criteria and were critically appraised. In total, 29.4% of domains had an unclear risk, 13.8% had a high risk and 56.8% had a low risk of bias. In comparison, ophthalmology articles from general medical journals had a lower prevalence of unclear risk (17.1%), higher prevalence of high risk (21.9%) and a higher prevalence of low risk domains (61.9%). Furthermore, 64.7% of critically appraised trials from ophthalmology-specific journals did not report any conflicts of interest, while 70.6% did not report an industry sponsor of their trial. In closing, it is essential that authors, peer reviewers and readers closely follow published risk of bias guidelines. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  3. Improving the effectiveness of service delivery in the public healthcare sector: the case of ophthalmology services in Malaysia.

    Science.gov (United States)

    Foo, Chee Yoong; Lim, Ka Keat; Sivasampu, Sheamini; Dahian, Kamilah Binti; Goh, Pik Pin

    2015-08-28

    Rising demand of ophthalmology care is increasingly straining Malaysia's public healthcare sector due to its limited human and financial resources. Improving the effectiveness of ophthalmology service delivery can promote national policy goals of population health improvement and system sustainability. This study examined the performance variation of public ophthalmology service in Malaysia, estimated the potential output gain and investigated several factors that might explain the differential performance. Data for 2011 and 2012 on 36 ophthalmology centres operating in the Ministry of Health hospitals were used in this analysis. We first consulted a panel of ophthalmology service managers to understand the production of ophthalmology services and to verify the production model. We then assessed the relative performance of these centres using Data Envelopment Analysis (DEA). Efficiency scores (ES) were decomposed into technical, scale, and congestion component. Potential increase in service output was estimated. Sensitivity analysis of model changes was performed and stability of the result was assessed using bootstrap approach. Second stage Tobit regression was conducted to determine if hospital type, availability of day services and population characteristics were related to the DEA scores. In 2011, 33% of the ophthalmology centres were found to have ES > 1 (mean ES = 1.10). Potential output gains were 10% (SE ± 2.92), 7.4% (SE ± 2.06), 6.9% (SE ± 1.97) if the centres could overcome their technical, scale and congestion inefficiencies. More centres moved to the performance frontier in 2012 (mean ES = 1.07), with lower potential output gain. The model used has good stability. Robustness checks show that the DEA correctly identified low performing centres. Being in state hospital was significantly associated with better performance. Using DEA to benchmarking service performance of ophthalmology care could provide insights for policy

  4. Comparison between flipped classroom and lecture-based classroom in ophthalmology clerkship

    Science.gov (United States)

    Tang, Fen; Chen, Chuan; Zhu, Yi; Zuo, Chengguo; Zhong, Yimin; Wang, Nan; Zhou, Lijun; Zou, Yuxian; Liang, Dan

    2017-01-01

    ABSTRACT Background: In recent years, the flipped classroom method of teaching has received much attention in health sciences education. However, the application of flipped classrooms in ophthalmology education has not been well investigated. Objective: The goal of this study was to investigate the effectiveness and acceptability of the flipped classroom approach to teaching ophthalmology at the clerkship level. Design: Ninety-five fourth year medical students in an ophthalmology clerkship were randomly divided into two groups. An ocular trauma module was chosen for the content of this study. One group (FG (flipped group), n = 48) participated in flipped classroom instruction and was asked to watch a recorded lecture video and to read study materials before a face-to-face class meeting. They used the in-class time for discussion. The other group (TG (traditional group), n = 47) was assigned to traditional lecture-based instruction. These students attended a didactic lecture and completed assigned homework after the lecture. Feedback questionnaires were collected to compare students’ perspectives on the teaching approach they experienced and to evaluate students’ self-perceived competence and interest in ocular trauma. Pre- and post-tests were performed to assess student learning of the course materials. Results: More students in the FG agreed that the classroom helped to promote their learning motivation, improve their understanding of the course materials, and enhance their communication skill and clinical thinking. However, students in the FG did not show a preference for this method of teaching, and also reported more burden and pressure than those from the TG. Students from the FG performed better on the post test over the ocular trauma-related questions when compared to those from the TG. Conclusions: The flipped classroom approach shows promise in ophthalmology clerkship teaching. However, it has some drawbacks. Further evaluation and modifications

  5. Comparison between flipped classroom and lecture-based classroom in ophthalmology clerkship.

    Science.gov (United States)

    Tang, Fen; Chen, Chuan; Zhu, Yi; Zuo, Chengguo; Zhong, Yimin; Wang, Nan; Zhou, Lijun; Zou, Yuxian; Liang, Dan

    2017-01-01

    In recent years, the flipped classroom method of teaching has received much attention in health sciences education. However, the application of flipped classrooms in ophthalmology education has not been well investigated. The goal of this study was to investigate the effectiveness and acceptability of the flipped classroom approach to teaching ophthalmology at the clerkship level. Ninety-five fourth year medical students in an ophthalmology clerkship were randomly divided into two groups. An ocular trauma module was chosen for the content of this study. One group (FG (flipped group), n = 48) participated in flipped classroom instruction and was asked to watch a recorded lecture video and to read study materials before a face-to-face class meeting. They used the in-class time for discussion. The other group (TG (traditional group), n = 47) was assigned to traditional lecture-based instruction. These students attended a didactic lecture and completed assigned homework after the lecture. Feedback questionnaires were collected to compare students' perspectives on the teaching approach they experienced and to evaluate students' self-perceived competence and interest in ocular trauma. Pre- and post-tests were performed to assess student learning of the course materials. More students in the FG agreed that the classroom helped to promote their learning motivation, improve their understanding of the course materials, and enhance their communication skill and clinical thinking. However, students in the FG did not show a preference for this method of teaching, and also reported more burden and pressure than those from the TG. Students from the FG performed better on the post test over the ocular trauma-related questions when compared to those from the TG. The flipped classroom approach shows promise in ophthalmology clerkship teaching. However, it has some drawbacks. Further evaluation and modifications are required before it can be widely accepted and implemented

  6. Measuring the differences in work ratios between pediatric and adult ophthalmologic examinations.

    Science.gov (United States)

    Hyun, Joo; Chang, Jee Ho; Kim, Seung Hoon; Park, Song Hee; Kim, Sunghoon

    2017-06-01

    To assess the differences in work needed for pediatric and adult ophthalmologic examinations. Seven ophthalmology residents conducted slit-lamp and refraction examinations on children 3-7 years of age and adults 20-69 years of age. The examiners reported the magnitude estimate (ME) of their work in relation to two references (cross-reference ME): average adult examination and average pediatric examination. The examination time was also measured. For the slit-lamp examination, 50 children and 58 adults were recruited. The ME was 1.45 (95% CI, 1.30-1.62) times higher for the pediatric examinations than for the adult examinations when the reference was an average adult case. With respect to time, the pediatric examinations took 1.22 (95% CI, 1.06-1.41) times longer than the adult examinations. For the refraction examinations, 58 children and 96 adults were recruited. The ME was 1.35 (95% CI, 1.21-1.52) times higher for the pediatric examinations. The pediatric examination took 1.32 (95% CI, 1.16-1.50) times longer than the adult examination. The cross-reference ME ratios measuring the pediatric over adult examinations against both the pediatric and adult reference cases were equivalent in both the slit-lamp and the refraction examinations; however, the ME and time ratios of the pediatric over the adult examinations were not equivalent for the slit-lamp or for the refraction examinations. The cross-reference ME showed that pediatric ophthalmologic examinations require more work than the adult examination with validity and reliability. The time estimate was insufficient as a single indicator for work estimation. Copyright © 2017 American Association for Pediatric Ophthalmology and Strabismus. Published by Elsevier Inc. All rights reserved.

  7. Representation of ophthalmology concepts by electronic systems: adequacy of controlled medical terminologies.

    Science.gov (United States)

    Chiang, Michael F; Casper, Daniel S; Cimino, James J; Starren, Justin

    2005-02-01

    To assess the adequacy of 5 controlled medical terminologies (International Classification of Diseases 9, Clinical Modification [ICD9-CM]; Current Procedural Terminology 4 [CPT-4]; Systematized Nomenclature of Medicine, Clinical Terms [SNOMED-CT]; Logical Identifiers, Names, and Codes [LOINC]; Medical Entities Dictionary [MED]) for representing concepts in ophthalmology. Noncomparative case series. Twenty complete ophthalmology case presentations were sequentially selected from a publicly available ophthalmology journal. Each of the 20 cases was parsed into discrete concepts, and each concept was classified along 2 axes: (1) diagnosis, finding, or procedure and (2) ophthalmic or medical concept. Electronic or paper browsers were used to assign a code for every concept in each of the 5 terminologies. Adequacy of assignment for each concept was scored on a 3-point scale. Findings from all 20 case presentations were combined and compared based on a coverage score, which was the average score for all concepts in that terminology. Adequacy of assignment for concepts in each terminology, based on a 3-point Likert scale (0, no match; 1, partial match; 2, complete match). Cases were parsed into 1603 concepts. SNOMED-CT had the highest mean overall coverage score (1.625+/-0.667), followed by MED (0.974+/-0.764), LOINC (0.781+/-0.929), ICD9-CM (0.280+/-0.619), and CPT-4 (0.082+/-0.337). SNOMED-CT also had higher coverage scores than any of the other terminologies for concepts in the diagnosis, finding, and procedure categories. Average coverage scores for ophthalmic concepts were lower than those for medical concepts. Controlled terminologies are required for electronic representation of ophthalmology data. SNOMED-CT had significantly higher content coverage than any other terminology in this study.

  8. The application of DECnet TTT technique in beam diagnostical system of SSC central region

    International Nuclear Information System (INIS)

    Zhang Guixu; Huang Tuanhua

    1997-01-01

    The DECnet TTT technique and the real time network communication based on DECnet TTT are presented. Information can be transferred between console and diagnostical system via DECnet communication, so all kinds of operation can be done on console. The working computer of HIRFL console is VAX8350

  9. [Microbiological and pharmacokinetic studies on flomoxef in ophthalmologic field].

    Science.gov (United States)

    Ooishi, M; Sakaue, F; Oomomo, A; Tazawa, H

    1989-05-01

    Microbiological and pharmacokinetic studies were carried out on flomoxef (FMOX, 6315-S), a new oxacephem parenteral antibiotic, in the ophthalmologic field. The results obtained are summarized as follows. FMOX has a broad antimicrobial activity spectrum against Gram-positive and Gram-negative bacteria. The MIC distribution against Staphylococcus aureus isolated from clinical cases was less than or equal to 0.20 - greater than or equal to 100 micrograms/ml with the peak value of 0.39 micrograms/ml. Concentrations of FMOX in aqueous humor and ocular tissues were determined after intravenous injection of 50 mg/kg to rabbits. FMOX showed a peak level of 2.2 micrograms/ml in the aqueous humor at 1/2 hour after administration with the ratio to serum level of 3.4%. Levels of FMOX in external and internal ocular tissues were 12.7 - 76.5 micrograms/g, less than 0.8 - 34.4 micrograms/g (ml) at 1/2 hour after administration, respectively. From these results, we concluded that FMOX may be expected to be a useful and valuable agent against infections in the ophthalmologic field.

  10. Fibrin glue in ophthalmology

    Directory of Open Access Journals (Sweden)

    Panda Anita

    2009-01-01

    Full Text Available Suturing is a time consuming task in ophthalmology and suture induced irritation and redness are frequent problems. Postoperative wound infection and corneal graft rejection are examples of possible suture related complications. To prevent these complications, ophthalmic surgeons are switching to sutureless surgery. A number of recent developments have established tissue adhesives like cyanoacrylate glue and fibrin glue as attractive alternatives to sutures. A possible and promising new application for tissue adhesives is to provide a platform for tissue engineering. Currently, tissue glue is being used for conjunctival closure following pterygium and strabismus surgery, forniceal reconstruction surgery, amniotic membrane transplantation, lamellar corneal grafting, closure of corneal perforations and descematoceles, management of conjunctival wound leaks after trabeculectomy, lid surgery, adnexal surgery and as a hemostat to minimise bleeding. The purpose of this review is to discuss the currently available information on fibrin glue.

  11. Contingent Valuation Analysis of an Otolaryngology and Ophthalmology Emergency Department: The Value of Acute Specialty Care.

    Science.gov (United States)

    Naunheim, Matthew R; Kozin, Elliot D; Sethi, Rosh K; Ota, H G; Gray, Stacey T; Shrime, Mark G

    2017-03-01

    Specialty emergency departments (EDs) provide a unique mechanism of health care delivery, but the value that they add to the medical system is not known. Evaluation of patient preferences to determine value can have a direct impact on resource allocation and direct-to-specialist care. To assess the feasibility of contingent valuation (CV) methodology using a willingness-to-pay (WTP) survey to evaluate specialty emergency services, in the context of an ophthalmology- and otolaryngology-specific ED. Contingent valuation analysis of a standalone otolaryngology and ophthalmology ED. Participants were English-speaking adults presenting to a dedicated otolaryngology and ophthalmology ED. The WTP questions were assessed using a payment card format, with reference to an alternative modality of treatment (ie, general ED), and were analyzed with multivariate regression. Validated WTP survey administered from October 14, 2014, through October 1, 2015. Sociodemographic data, level of distress, referral data, income, and WTP. A total of 327 of 423 (77.3%) ED patients responded to the WTP survey, with 116 ophthalmology and 211 otolaryngology patients included (52.3% female; mean [range] age, 46 [18-90] years). The most common reason for seeking care at this facility was a reputation for specialty care for both ear, nose, and throat (80 [37.9%]) and ophthalmology (43 [37.1%]). Mean WTP for specialty-specific ED services was $377 for ophthalmology patients, and $321 for otolaryngology patients ($340 overall; 95% CI, $294 to $386), without significant difference between groups (absolute difference, $56; 95% CI, $-156 to $43). Self-reported level of distress was higher among ear, nose, and throat vs ophthalmology patients (absolute difference, 0.47 on a Likert scale of 1-7; 95% CI, 0.10 to 0.84). Neither level of distress, income, nor demographic characteristics influenced WTP, but patients with higher estimates of total visit cost were more likely to have higher WTP (β coefficient

  12. Creation of an Accurate Algorithm to Detect Snellen Best Documented Visual Acuity from Ophthalmology Electronic Health Record Notes.

    Science.gov (United States)

    Mbagwu, Michael; French, Dustin D; Gill, Manjot; Mitchell, Christopher; Jackson, Kathryn; Kho, Abel; Bryar, Paul J

    2016-05-04

    Visual acuity is the primary measure used in ophthalmology to determine how well a patient can see. Visual acuity for a single eye may be recorded in multiple ways for a single patient visit (eg, Snellen vs. Jäger units vs. font print size), and be recorded for either distance or near vision. Capturing the best documented visual acuity (BDVA) of each eye in an individual patient visit is an important step for making electronic ophthalmology clinical notes useful in research. Currently, there is limited methodology for capturing BDVA in an efficient and accurate manner from electronic health record (EHR) notes. We developed an algorithm to detect BDVA for right and left eyes from defined fields within electronic ophthalmology clinical notes. We designed an algorithm to detect the BDVA from defined fields within 295,218 ophthalmology clinical notes with visual acuity data present. About 5668 unique responses were identified and an algorithm was developed to map all of the unique responses to a structured list of Snellen visual acuities. Visual acuity was captured from a total of 295,218 ophthalmology clinical notes during the study dates. The algorithm identified all visual acuities in the defined visual acuity section for each eye and returned a single BDVA for each eye. A clinician chart review of 100 random patient notes showed a 99% accuracy detecting BDVA from these records and 1% observed error. Our algorithm successfully captures best documented Snellen distance visual acuity from ophthalmology clinical notes and transforms a variety of inputs into a structured Snellen equivalent list. Our work, to the best of our knowledge, represents the first attempt at capturing visual acuity accurately from large numbers of electronic ophthalmology notes. Use of this algorithm can benefit research groups interested in assessing visual acuity for patient centered outcome. All codes used for this study are currently available, and will be made available online at https://phekb.org.

  13. Ophthalmology patients' interest in online access to clinic notes at three US clinics.

    Science.gov (United States)

    Lee, Bryan S; Oster, Natalia V; Chen, Galen Y; Ding, Leona L; Walker, Janice D; Elmore, Joann G

    2017-07-01

    This study aimed to understand patients' perceptions about potential benefits and harms of accessing their own ophthalmology clinic notes via an electronic patient portal as part of the OpenNotes initiative. The authors conducted a cross-sectional, in-person survey of ophthalmology patients at three US eye clinics. The paper survey was self-administered or administered with assistance from study staff before or after patients' clinical visits. The authors used descriptive statistics to summarise patient characteristics and patient attitudes about accessing their ophthalmology notes online. Chi-square and t-tests were performed to assess differences in patient responses between clinic locations. Four hundred and fifty-one patients responded (response rate 65%). Most patients thought that accessing doctors' notes online was a good idea (95%), wanted to view their clinic notes online (94%), and agreed online access would increase their understanding of their eye problems (95%) and help them better remember their care plan (94%); 14% said online access would increase their worry; 43% had privacy concerns; and 96% indicated they would show or discuss their notes with at least one other person. Non-white patients were more likely than white patients to perceive online clinic notes as a useful tool, but they were also more likely to worry and to express greater privacy concerns. Patients at three US eye clinics were strongly in favour of online access to ophthalmology notes and were optimistic this access would improve their understanding and self-care. Ophthalmologists should consider offering online access to their notes to enhance doctor-patient communication and improve clinical outcomes. © 2017 The Authors Ophthalmic & Physiological Optics © 2017 The College of Optometrists.

  14. Evaluation of Temporal Diagnostic Techniques for Two-Bunch Facet Beam

    Energy Technology Data Exchange (ETDEWEB)

    Litos, M.D.; Bionta, M.R.; Dolgashev, V.A.; England, R.J.; Fritz, D.; Gilevich, S.; Hering, Ph.; Hogan, M.J.; /SLAC

    2011-08-19

    Three temporal diagnostic techniques are considered for use in the FACET facility at SLAC, which will incorporate a unique two-bunch beam for plasma wakefield acceleration experiments. The results of these experiments will depend strongly on the the inter-bunch spacing as well as the longitudinal profiles of the two bunches. A reliable, singleshot, high resolution measurement of the beam's temporal profile is necessary to fully quantify the physical mechanisms underlying the beam driven plasma wakefield acceleration. In this study we show that a transverse deflecting cavity is the diagnostic which best meets our criteria. Based on our laboratory testing, numerical calculations, and simulations of the three single-shot temporal diagnostic devices, the X-band TCAV system is the best candidate for resolving FACET's two-bunch beam, with an estimated resolution of 7 {micro}m. Both the S-band TCAV system and the EO system could resolve the peak-to-peak separation of the two bunches in the FACET beam with estimated resolutions of 25 {micro}m and 30 {micro}m, respectively, but would be unable to resolve the temporal profiles of the individual bunches themselves. Because the TCAV signal is more easily interpreted and because the reliability of the EO system is less well known, however, the S-band TCAV system would be the next preferred option after the X-band TCAV system. The Fesca-200 streak camera, though simple, compact, and reliable, is unable to achieve a resolution that would be of use to FACET.

  15. Neuro-ophthalmological approach to facial nerve palsy.

    Science.gov (United States)

    Portelinha, Joana; Passarinho, Maria Picoto; Costa, João Marques

    2015-01-01

    Facial nerve palsy is associated with significant morbidity and can have different etiologies. The most common causes are Bell's palsy, Ramsay-Hunt syndrome and trauma, including surgical trauma. Incidence varies between 17 and 35 cases per 100,000. Initial evaluation should include accurate clinical history, followed by a comprehensive investigation of the head and neck, including ophthalmological, otological, oral and neurological examination, to exclude secondary causes. Routine laboratory testing and diagnostic imaging is not indicated in patients with new-onset Bell's palsy, but should be performed in patients with risk factors, atypical cases or in any case without resolution within 4 months. Many factors are involved in determining the appropriate treatment of these patients: the underlying cause, expected duration of nerve dysfunction, anatomical manifestations, severity of symptoms and objective clinical findings. Systemic steroids should be offered to patients with new-onset Bell's palsy to increase the chance of facial nerve recovery and reduce synkinesis. Ophthalmologists play a pivotal role in the multidisciplinary team involved in the evaluation and rehabilitation of these patients. In the acute phase, the main priority should be to ensure adequate corneal protection. Treatment depends on the degree of nerve lesion and on the risk of the corneal damage based on the amount of lagophthalmos, the quality of Bell's phenomenon, the presence or absence of corneal sensitivity and the degree of lid retraction. The main therapy is intensive lubrication. Other treatments include: taping the eyelid overnight, botulinum toxin injection, tarsorrhaphy, eyelid weight implants, scleral contact lenses and palpebral spring. Once the cornea is protected, longer term planning for eyelid and facial rehabilitation may take place. Spontaneous complete recovery of Bell's palsy occurs in up to 70% of cases. Long-term complications include aberrant regeneration with

  16. A forecast of ophthalmology practice trends in saudi arabia: a survey of junior residents.

    Science.gov (United States)

    Alwadani, Fahad; Alrushood, Aziz; Altokhy, Hisham; Alasbali, Tariq

    2010-10-01

    The aim of this study is to identify the trends in practice pattern among current ophthalmology residents in Saudi Arabia. Ophthalmology residents in Saudi Arabia responded anonymously to a written survey between November 2007 and February 2008. The survey contained questions on demographic information, medical education, residency training, career goals and factors influencing their career choice. The data were categorized by gender. The influence of gender on outcome was assessed in a univariate fashion using the Chi-square or Fisher exact test when appropriate. A P-value of 0.05 or less was considered statistically significant for all analyses. A total of 68 out of 85 residents (80%) responded to the survey. Over one-half of the residents preferred to pursue a fellowship within Saudi Arabia (53%), while others (25%) planned to train in North America. The majority of respondents wished to practice in an urban setting (63%). Anterior segment was the most desired subspecialty, while general ophthalmology and glaucoma were not a popular choice. Most residents were interested in refractive surgery (77%) and research (75%). The main factor influencing the decision to pursue ophthalmology was the ability to combine medicine and surgery (97%), while a positive elective experience was also an important factor, particularly for female respondents (91% vs. 57%; P < 0.001). Concerted efforts are required to encourage adoption to ophthalmic practice in public institutions rather than in private practice. In addition training in underrepresented subspecilaties should be encouraged to ensure adequate ophthalmic care for all citizens of Saudi Arabia.

  17. Intercomparison of techniques for inspection and diagnostics of heavy water reactor pressure tubes. Additional information

    International Nuclear Information System (INIS)

    2009-03-01

    The reports from Argentina, Canada, India, Korea and Romania are presented concerning the projects carried out under the Coordinated Research Program (CRP) I3.30.10 of the International Agency for Atomic Energy - Vienna related to 'Intercomparison of Techniques for Pressure Tube Inspection and Diagnostics'

  18. [Understanding the advantages and disadvantages of femtosecond laser comprehensive applications in ophthalmology].

    Science.gov (United States)

    Xie, Li-xin; Gao, Hua

    2013-04-01

    The femtosecond (FS) laser is a novel laser technology, and is approved clinical application by FDA in 2000. FS laser initially mainly used in corneal refractive surgery to replace the mechanical microkeratome. Since the accuracy and controllability of the FS laser is very high, it shows superiority in the field of corneal refractive surgery. And with the development of the relative hard and software, FS laser is began to used in other fields of ophthalmology, such as corneal transplants, cataract surgery, as well as assisted diagnosis et al., although still have some limitations, the preliminary clinical results have been shown a very good prospects in the ophthalmology fields. Therefore, we reviewed the alternative applications, challenges and limitations, research direction in the future of FS laser, so that provide a reference and revelations for the peers.

  19. The QuantiFERON-TB Gold In-Tube Assay in Neuro-Ophthalmology.

    Science.gov (United States)

    Little, Leanne M; Rigi, Mohammed; Suleiman, Ayman; Smith, Stacy V; Graviss, Edward A; Foroozan, Rod; Lee, Andrew G

    2017-09-01

    Although QuantiFERON-TB Gold In-Tube (QFT-GIT) testing is regularly used to detect infection with Mycobacterium tuberculosis, its utility in a patient population with a low risk for tuberculosis (TB) has been questioned. The following is a cohort study analyzing the efficacy of QFT-GIT testing as a method for detection of active TB disease in low-risk individuals in a neuro-ophthalmologic setting. Ninety-nine patients from 2 neuro-ophthalmology centers were identified as having undergone QFT-GIT testing between January 2012 and February 2016. Patients were divided into groups of negative, indeterminate, and positive QFT-GIT results. Records of patients with positive QFT-GIT results were reviewed for development of latent or active TB, as determined by clinical, bacteriologic, and/or radiographic evidence. Of the 99 cases reviewed, 18 patients had positive QFT-GIT tests. Of these 18 cases, 12 had documentation of chest radiographs or computed tomography which showed no evidence for either active TB or pulmonary latent TB infection (LTBI). Four had chest imaging which was indicative of possible LTBI. None of these 18 patients had symptoms of active TB and none developed active TB within the follow-up period. Based on our results, we conclude that routine testing with QFT-GIT in a low-risk cohort did not diagnose active TB infection. We do not recommend routine QFT-GIT testing for TB low-risk individuals, as discerned through patient and exposure history, ocular examination, and clinical judgment, in neuro-ophthalmology practice.

  20. Electronic Referrals and Digital Imaging Systems in Ophthalmology: A Global Perspective.

    Science.gov (United States)

    Jeganathan, V Swetha E; Hall, H Nikki; Sanders, Roshini

    2017-01-01

    Ophthalmology departments face intensifying pressure to expedite sight-saving treatments and reduce the global burden of disease. The use of electronic communication systems, digital imaging, and redesigned service care models is imperative for addressing such demands. The recently developed Scottish Eyecare Integration Project involves an electronic referral system from community optometry to the hospital ophthalmology department using National Health Service (NHS) email with digital ophthalmic images attached, via a virtual private network connection. The benefits over the previous system include reduced waiting times, improved triage, e-diagnosis in 20% without the need for hospital attendance, and rapid electronic feedback to referrers. We draw on the experience of the Scottish Eyecare Integration Project and discuss the global applications of this and other advances in teleophthalmology. We focus particularly on the implications for management and screening of chronic disease, such as glaucoma and diabetic eye disease, and ophthalmic disease, such as retinopathy of prematurity where diagnosis is almost entirely and critically dependent on fundus appearance. Currently in Scotland, approximately 75% of all referrals are electronic from community to hospital. The Scottish Eyecare Integration Project is globally the first of its kind and unique in a national health service. Such speedy, safe, and efficient models of communication are geographically sensitive to service provision, especially in remote and rural regions. Along with advances in teleophthalmology, such systems promote the earlier detection of sight-threatening disease and safe follow-up of non-sight-threatening disease in the community. Copyright© 2017 Asia-Pacific Academy of Ophthalmology.

  1. Leadership in Ophthalmology: The Role of Physician-MBAs.

    Science.gov (United States)

    Pathipati, Akhilesh S; Tsai, James C

    2018-04-01

    As American health care evolves, an increasing number of doctors are pursuing MBAs. However, relatively little is known about how business training translates into their future careers. This study characterizes ophthalmologists who have completed MBAs and identifies opportunities for physician leadership in the field. Cross-sectional study. We identified 120 ophthalmologists who hold MBAs. We searched each individual's online profiles to collect information on demographics, training, and professional activities. Physician-MBAs in ophthalmology are 80% male; 80% are fellowship trained; and 28% are in primarily nonclinical roles and 55% participate in significant nonclinical activity. Hospital administration is most common (31%), followed by pharmaceutical administration (7%) and consulting (5%). Older ophthalmologist-MBAs were more likely to work in nonclinical roles, with 79% of those who completed residency before 2000 engaged in significant nonclinical activity compared to 30% of those who completed residency after 2000. The most common employers of physician-MBAs in ophthalmology are academic medical centers (43%), large group practices (30%), and private practices (13%). The majority of ophthalmologist-MBAs work in primarily clinical roles, although a sizable proportion hold nonclinical positions. Moving forward, we anticipate an increased role for physician leaders in health care administration, policy, and entrepreneurship. While formal management training is not necessary for these roles, a growing number of physicians have sought out MBAs to support their nonclinical interests. Copyright © 2018 Elsevier Inc. All rights reserved.

  2. Application of OCT angiography in ophthalmology

    Directory of Open Access Journals (Sweden)

    Ai-Ping Yang

    2017-11-01

    Full Text Available Optical coherence tomography angiography(OCTAis a new technology of angiography in recent years. In addition to the advantages of traditional OCT, it can observe blood flow in different retinal and choroidal segmentation slab. By using the pseudo-color, abnormal vascular structure can be distinguished from normal vascular structure of the retina. Dye injection is not needed with OCTA, which is different from fundus fluorescein angiography(FFAand indocyanine green angiography(ICGA. OCTA provides more and more accurate blood flow information. However, like other biometric technology, OCTA has its limitations and shortcomings. This review will analyze and summarize the operating principle of OCTA, its application in ophthalmology, as well as its advantages and limitations.

  3. The Role of Flow Diagnostic Techniques in Fan and Open Rotor Noise Modeling

    Science.gov (United States)

    Envia, Edmane

    2016-01-01

    A principal source of turbomachinery noise is the interaction of the rotating and stationary blade rows with the perturbations in the airstream through the engine. As such, a lot of research has been devoted to the study of the turbomachinery noise generation mechanisms. This is particularly true of fan and open rotors, both of which are the major contributors to the overall noise output of modern aircraft engines. Much of the research in fan and open rotor noise has been focused on developing theoretical models for predicting their noise characteristics. These models, which run the gamut from the semi-empirical to fully computational ones, are, in one form or another, informed by the description of the unsteady flow-field in which the propulsors (i.e., the fan and open rotors) operate. Not surprisingly, the fidelity of the theoretical models is dependent, to a large extent, on capturing the nuances of the unsteady flowfield that have a direct role in the noise generation process. As such, flow diagnostic techniques have proven to be indispensible in identifying the shortcoming of theoretical models and in helping to improve them. This presentation will provide a few examples of the role of flow diagnostic techniques in assessing the fidelity and robustness of the fan and open rotor noise prediction models.

  4. The polaroid suppression test in a pediatric population with ophthalmologic disorders

    NARCIS (Netherlands)

    Pott, JWR; Kingma, C; Verhoeff, K; Grootendorst, RJ; de Faber, JTHN

    Purpose: The Polaroid suppression test (PST) is a new method for early detection of amblyogenic factors by screening for suppression. The apparatus can elicit suppression with the use of Polaroid filters. The aim of the present study was to examine a population of children with known ophthalmologic

  5. Iterative reconstruction technique with reduced volume CT dose index: diagnostic accuracy in pediatric acute appendicitis

    International Nuclear Information System (INIS)

    Didier, Ryne A.; Vajtai, Petra L.; Hopkins, Katharine L.

    2015-01-01

    Iterative reconstruction technique has been proposed as a means of reducing patient radiation dose in pediatric CT. Yet, the effect of such reductions on diagnostic accuracy has not been thoroughly evaluated. This study compares accuracy of diagnosing pediatric acute appendicitis using contrast-enhanced abdominopelvic CT scans performed with traditional pediatric weight-based protocols and filtered back projection reconstruction vs. a filtered back projection/iterative reconstruction technique blend with reduced volume CT dose index (CTDI vol ). Results of pediatric contrast-enhanced abdominopelvic CT scans done for pain and/or suspected appendicitis were reviewed in two groups: A, 192 scans performed with the hospital's established weight-based CT protocols and filtered back projection reconstruction; B, 194 scans performed with iterative reconstruction technique and reduced CTDI vol . Reduced CTDI vol was achieved primarily by reductions in effective tube current-time product (mAs eff ) and tube peak kilovoltage (kVp). CT interpretation was correlated with clinical follow-up and/or surgical pathology. CTDI vol , size-specific dose estimates (SSDE) and performance characteristics of the two CT techniques were then compared. Between groups A and B, mean CTDI vol was reduced by 45%, and mean SSDE was reduced by 46%. Sensitivity, specificity and diagnostic accuracy were 96%, 97% and 96% in group A vs. 100%, 99% and 99% in group B. Accuracy in diagnosing pediatric acute appendicitis was maintained in contrast-enhanced abdominopelvic CT scans that incorporated iterative reconstruction technique, despite reductions in mean CTDI vol and SSDE by nearly half as compared to the hospital's traditional weight-based protocols. (orig.)

  6. Optical diagnostics of vascular reactions triggered by weak allergens using laser speckle-contrast imaging technique

    International Nuclear Information System (INIS)

    Kuznetsov, Yu L; Kalchenko, V V; Astaf'eva, N G; Meglinski, I V

    2014-01-01

    The capability of using the laser speckle contrast imaging technique with a long exposure time for visualisation of primary acute skin vascular reactions caused by a topical application of a weak contact allergen is considered. The method is shown to provide efficient and accurate detection of irritant-induced primary acute vascular reactions of skin. The presented technique possesses a high potential in everyday diagnostic practice, preclinical studies, as well as in the prognosis of skin reactions to the interaction with potentially allergenic materials. (laser biophotonics)

  7. Optical diagnostics of vascular reactions triggered by weak allergens using laser speckle-contrast imaging technique

    Energy Technology Data Exchange (ETDEWEB)

    Kuznetsov, Yu L; Kalchenko, V V [Department of Veterinary Resources, Weizmann Institute of Science, Rehovot, 76100 (Israel); Astaf' eva, N G [V.I.Razumovsky Saratov State Medical University, Saratov (Russian Federation); Meglinski, I V [N.G. Chernyshevsky Saratov State University, Saratov (Russian Federation)

    2014-08-31

    The capability of using the laser speckle contrast imaging technique with a long exposure time for visualisation of primary acute skin vascular reactions caused by a topical application of a weak contact allergen is considered. The method is shown to provide efficient and accurate detection of irritant-induced primary acute vascular reactions of skin. The presented technique possesses a high potential in everyday diagnostic practice, preclinical studies, as well as in the prognosis of skin reactions to the interaction with potentially allergenic materials. (laser biophotonics)

  8. Consideration on the diagnostic ability of various imaging techniques in relation to renal tumor

    International Nuclear Information System (INIS)

    Ike, Katsushi

    1984-01-01

    Radiological diagnosis of renal tumors is being improved with the increased imaging accuracy which has resulted from advancement in the various equipment used and improvement in techniques. However, at the clinical level, diagnostic procedures based on the characteristics of the delineated images are not yet established and the diverse diagnostic procedures are being conducted currently in a stereotyped manner. In this study, the images of 61 cases diagnosed as renal tumor were analysed retrospectively with the purpose of establishing the imaging accuracy, capacity for diagnosis based on image characteristics and a subseguent proper diagnostic procedure. It was found that CT and Angio gave similar diagnostic accuracy. It was further revealed that US images enabled to differentiate renal tumors from the more commonly experienced renal cystic disease. For determination of tunica involucrum infiltration, which is essential to diagnose Stage I and II renal tumors, CT was proved to be superior to Angio. CT and US were also to be so in the determination of metastasis to para-aortic lymph nodes which is a Stage III criterion. In recent years, CT and US imaging accuracies have increased, hence the improvement in the capacity to diagnose non-observable renal tumors is highly expected. (author)

  9. Plasma diagnostics discharge parameters and chemistry

    CERN Document Server

    Auciello, Orlando

    1989-01-01

    Plasma Diagnostics, Volume 1: Discharge Parameters and Chemistry covers seven chapters on the important diagnostic techniques for plasmas and details their use in particular applications. The book discusses optical diagnostic techniques for low pressure plasmas and plasma processing; plasma diagnostics for electrical discharge light sources; as well as Langmuir probes. The text also describes the mass spectroscopy of plasmas, microwave diagnostics, paramagnetic resonance diagnostics, and diagnostics in thermal plasma processing. Electrical engineers, nuclear engineers, microwave engineers, che

  10. Veterinary Molecular Diagnostics

    NARCIS (Netherlands)

    Roest, H.I.J.; Engelsma, M.Y.; Weesendorp, E.; Bossers, A.; Elbers, A.R.W.

    2017-01-01

    In veterinary molecular diagnostics, samples originating from animals are tested. Developments in the farm animals sector and in our societal attitude towards pet animals have resulted in an increased demand for fast and reliable diagnostic techniques. Molecular diagnostics perfectly matches this

  11. [Application of molecular diagnostic techniques in precision medicine of personalized treatment for colorectal cancer].

    Science.gov (United States)

    Fu, Ji; Lin, Guole

    2016-01-01

    Precision medicine is to customize the treatment options for individual patient based on the personal genome information. Colorectal cancer (CRC) is one of the most common cancer worldwide. Molecular heterogeneity of CRC, which includes the MSI phenotype, hypermutation phenotype, and their relationship with clinical preferences, is believed to be one of the main factors responsible for the considerable variability in treatment response. The development of powerful next-generation sequencing (NGS) technologies allows us to further understand the biological behavior of colorectal cancer, and to analyze the prognosis and chemotherapeutic drug reactions by molecular diagnostic techniques, which can guide the clinical treatment. This paper will introduce the new findings in this field. Meanwhile we integrate the new progress of key pathways including EGFR, RAS, PI3K/AKT and VEGF, and the experience in selective patients through associated molecular diagnostic screening who gain better efficacy after target therapy. The technique for detecting circulating tumor DNA (ctDNA) is introduced here as well, which can identify patients with high risk for recurrence, and demonstrate the risk of chemotherapy resistance. Mechanism of tumor drug resistance may be revealed by dynamic observation of gene alteration during treatment.

  12. Radiation-related ophthalmologic changes and aging among the atomic bomb survivors

    International Nuclear Information System (INIS)

    Otake, Masanori; Finch, S.C.; Choshi, Kanji; Takaku, Isao; Mishima, Hiromu; Takase, Tomoko.

    1993-05-01

    The relationship of ionizing radiation to the age-related ophthalmologic findings of the 1978-80 ophthalmologic examination of the atomic bomb (A-bomb) survivors of Hiroshima and Nagasaki has been reanalyzed using Dosimetry System 1986 eye organ dose estimates. The main purpose of this re-evaluation was to determine whether age and radiation exposure have an additive, synergistic, or antagonistic effect on ophthalmologic changes. The best model fitting axial opacities gives a significant positive effect for both linear dose-response and linear age-related regression coefficients and a significant negative effect for an interaction between radiation dose and age. Such a negative interaction implies an antagonistic effect in that the relative risks with relation to radiation doses decrease with increasing age. This phenomenon suggests that the lenses of younger persons are more sensitive to radiation than are those of older persons. However, the best-fitting relationship for posterior subcapsular changes suggested a linear-quadratic dose response and linear age-related effects. The quadratic estimate of radiation dose squared showed a highly significant effect with a negative trend, but the negative quadratic estimate was so extremely small it had almost no contributive value within an appropriative dose area. These data suggest an additive relationship between aging and radiation for the induction of posterior subcapsular changes, and they also indicate that there is no distinct evidence of a radiation-induced aging effect. The radiation-related relative risks increase with a log linearity. The decrease of visual acuity and accommodation with increasing age were comparable in both exposed and control subjects, with age-related visual acuity decreasing more than accommodation. (J.P.N.)

  13. [Study of the impact of a MBA Administration in Health course on the organizational modernity of ophthalmologic clinics].

    Science.gov (United States)

    Meireles, Manuel; Scarpi, Marinho Jorge

    2005-01-01

    Investigations in the field of the learning competence that investigate the impact of the acquisition of new individual competence of those responsible for ophthalmologic clinics, by means of a MBA Administration in Health course, on the organizational modernity of ophthalmologic clinics. Survey using questionnaires applied to students and former students of the course and to managers of ophthalmologic clinics not linked to the course (n=30 each one). The analysis was made by means of statistical methods: r of Pearson and Q of Yule; Student's t test, sum of series test, median test and U test of Mann-Whitney. Linear and positive correlation was observed between excellency of MBA Administration in Health and the development of the veteran students' capacities (rho correlation of Spearman at the level of 0.01); there is a significant difference (0.0364, by the Mann-Whitney test), between veteran students and freshmen regarding the need to extend the individual capacities provided by the MBA Administration in Health course, to the other operational employees of the ophthalmologic clinics; and there is a significant difference (0.0057, for the Mann-Whitney test), among veteran students of the MBA Administration in Health course and freshmen regarding the importance of the organizational modernity for the ophthalmologic clinics. The obtained results are consistent, in a general way, with the proposed model: MBA Administration's excellence in Health contributes significantly to the organizational modernity, to the development of competence of the veteran students, and, also in substantial way to the perception of organizational hiatuses.

  14. Uses and complications of mitomycin C in ophthalmology.

    Science.gov (United States)

    Mearza, Ali A; Aslanides, Ioannis M

    2007-01-01

    Mitomycin C is a chemotherapeutic agent that acts by inhibiting DNA synthesis. Its use and application in ophthalmology has been increasing in recent years because of its modulatory effects on wound healing. Current applications include pterygium surgery, glaucoma surgery, corneal refractive surgery, cicatricial eye disease, conjunctival neoplasia and allergic eye disease. Although it has been used successfully in these conditions, it has also been associated with significant complications. This article reviews the current trends and uses of mitomycin C in the eye and its reported complications.

  15. Diagnostic evaluation of rolling behavior in ball bearings by ultrasonic technique

    International Nuclear Information System (INIS)

    Wakabayashi, T

    2012-01-01

    Failures of machines having rotating parts are mostly caused by damage to bearings and there exist increasing demands for detecting damaged bearings at an early stage. However, conventional diagnostic methods, such as measuring temperature and observing vibration, have found difficulties in performing the early detection, so that more advanced diagnosis is necessary. This study therefore applies an ultrasonic technique as an advanced diagnostic method to bearing life tests. Ultrasonic wave pulses (UWP) emitted from a piezoelectric UWP generator can partially reflect from the interfaces of contact zones within the housing and the bearing with regard to the different acoustic impedance between a solid-to-solid contact and a contact dominated by some fluid layers. Hence, the intensity of the resultant UWP echoes can be determined by the real contact area formed at the interfaces. The experimental results of UWP echoes under the different operating conditions have demonstrated that the time intervals between peaks of UWP echoes varied in accordance with the movement of rolling balls and the lubricating phenomena in bearings. This behavior has further suggested the possibility of the early detection of abnormalities in ball bearings by using the variation in UWP echoes.

  16. Development and applications of laser spectroscopic techniques related to combustion diagnostics

    International Nuclear Information System (INIS)

    Alden, Marcus

    2006-01-01

    Thanks to features as non-intrusiveness combined with high spatial and temporal resolution, various laser diagnostic techniques have during the last decades become of utmost importance for characterization of combustion related phenomena. In the following presentation some further development of the techniques will be highlighted aiming at a) surface temperatures using Thermographic Phosphors, TP, b) species specific, spatially and temporally resolved detection of species absorbing in the IR spectral region using polarization spectroscopy and Laser-induced fluorescence, and finally c) high speed visualization using a special designed laser system in combination with a framing camera. In terms of surface thermometry, Thermographic Phosphors have been used for many years for temperature measurements on solid surfaces. We have during the last years further developed and applied this technique for temperature measurements on burning surfaces and on materials going through phase shifts, e.g. pyrolysis and droplets. The basic principle behind this technique is to apply micron size particles to the surface of interest. By exciting the TP with a short pulse UV laser (ns), the phosphorescence will exhibit a behaviour where the spectral emission as well as the temporal decay are dependent on the temperature. It is thus possible to measure the temperature both in one and two dimensions. The presentation will include basic description of the technique as well as various applications, e.g in fire science, IC engines and gasturbines. Several of the species of interest for combustion/flow diagnostics exhibit a molecular structure which inhibits the use of conventional laser-induced fluorescence for spatially and spectrally resolved measurements. We have during the last years investigated the use of excitation and detection in the infrared region of the spectrum. Here, it is possible to detect both carbonmono/dioxide, water as well as species specific hydrocarbons. The techniques

  17. A Comprehensive Proteomics Analysis of the Human Iris Tissue: Ready to Embrace Postgenomics Precision Medicine in Ophthalmology?

    Science.gov (United States)

    Murthy, Krishna R; Dammalli, Manjunath; Pinto, Sneha M; Murthy, Kalpana Babu; Nirujogi, Raja Sekhar; Madugundu, Anil K; Dey, Gourav; Subbannayya, Yashwanth; Mishra, Uttam Kumar; Nair, Bipin; Gowda, Harsha; Prasad, T S Keshava

    2016-09-01

    The annual economic burden of visual disorders in the United States was estimated at $139 billion. Ophthalmology is therefore one of the salient application fields of postgenomics biotechnologies such as proteomics in the pursuit of global precision medicine. Interestingly, the protein composition of the human iris tissue still remains largely unexplored. In this context, the uveal tract constitutes the vascular middle coat of the eye and is formed by the choroid, ciliary body, and iris. The iris forms the anterior most part of the uvea. It is a thin muscular diaphragm with a central perforation called pupil. Inflammation of the uvea is termed uveitis and causes reduced vision or blindness. However, the pathogenesis of the spectrum of diseases causing uveitis is still not very well understood. We investigated the proteome of the iris tissue harvested from healthy donor eyes that were enucleated within 6 h of death using high-resolution Fourier transform mass spectrometry. A total of 4959 nonredundant proteins were identified in the human iris, which included proteins involved in signaling, cell communication, metabolism, immune response, and transport. This study is the first attempt to comprehensively profile the global proteome of the human iris tissue and, thus, offers the potential to facilitate biomedical research into pathological diseases of the uvea such as Behcet's disease, Vogt Koyonagi Harada's disease, and juvenile rheumatoid arthritis. Finally, we make a call to the broader visual health and ophthalmology community that proteomics offers a veritable prospect to obtain a systems scale, functional, and dynamic picture of the eye tissue in health and disease. This knowledge is ultimately pertinent for precision medicine diagnostics and therapeutics innovation to address the pressing needs of the 21st century visual health.

  18. A Randomized Controlled Study of Art Observation Training to Improve Medical Student Ophthalmology Skills.

    Science.gov (United States)

    Gurwin, Jaclyn; Revere, Karen E; Niepold, Suzannah; Bassett, Barbara; Mitchell, Rebecca; Davidson, Stephanie; DeLisser, Horace; Binenbaum, Gil

    2018-01-01

    Observation and description are critical to the practice of medicine, and to ophthalmology in particular. However, medical education does not provide explicit training in these areas, and medical students are often criticized for deficiencies in these skills. We sought to evaluate the effects of formal observation training in the visual arts on the general and ophthalmologic observational skills of medical students. Randomized, single-masked, controlled trial. Thirty-six first-year medical students, randomized 1:1 into art-training and control groups. Students in the art-training group were taught by professional art educators at the Philadelphia Museum of Art, during 6 custom-designed, 1.5-hour art observation sessions over a 3-month period. All subjects completed pre- and posttesting, in which they described works of art, retinal pathology images, and external photographs of eye diseases. Grading of written descriptions for observational and descriptive abilities by reviewers using an a priori rubric and masked to group assignment and pretesting/posttesting status. Observational skills, as measured by description testing, improved significantly in the training group (mean change +19.1 points) compared with the control group (mean change -13.5 points), P = 0.001. There were significant improvements in the training vs. control group for each of the test subscores. In a poststudy questionnaire, students reported applying the skills they learned in the museum in clinically meaningful ways at medical school. Art observation training for first-year medical students can improve clinical ophthalmology observational skills. Principles from the field of visual arts, which is reputed to excel in teaching observation and descriptive abilities, can be successfully applied to medical training. Further studies can examine the impact of such training on clinical care. Copyright © 2017 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  19. Multimodal imaging of vascular network and blood microcirculation by optical diagnostic techniques

    International Nuclear Information System (INIS)

    Kuznetsov, Yu L; Kalchenko, V V; Meglinski, I V

    2011-01-01

    We present a multimodal optical diagnostic approach for simultaneous non-invasive in vivo imaging of blood and lymphatic microvessels, utilising a combined use of fluorescence intravital microscopy and a method of dynamic light scattering. This approach makes it possible to renounce the use of fluorescent markers for visualisation of blood vessels and, therefore, significantly (tenfold) reduce the toxicity of the technique and minimise side effects caused by the use of contrast fluorescent markers. We demonstrate that along with the ability to obtain images of lymph and blood microvessels with a high spatial resolution, current multimodal approach allows one to observe in real time permeability of blood vessels. This technique appears to be promising in physiology studies of blood vessels, and especially in the study of peripheral cardiovascular system in vivo. (optical technologies in biophysics and medicine)

  20. Novel Nonlinear Laser Diagnostic Techniques

    Science.gov (United States)

    1993-07-01

    a thermometric probe of reactive flows. Since the two-photon pump laser couples a Doppler broadened ground state velocity distribution to the excited...rism, and passed unfocused into an aluminum cell con- in frequency space. Regions for line fitting are found by taining 99% pure NO. The gas mixture...of ASE as a More recently, ASE has prompted interest as an thermometric probe of combustion environments optical diagnostic of combustion environments

  1. A novel non-invasive diagnostic sampling technique for cutaneous leishmaniasis.

    Directory of Open Access Journals (Sweden)

    Yasaman Taslimi

    2017-07-01

    Full Text Available Accurate diagnosis of cutaneous leishmaniasis (CL is important for chemotherapy and epidemiological studies. Common approaches for Leishmania detection involve the invasive collection of specimens for direct identification of amastigotes by microscopy and the culturing of promastigotes from infected tissues. Although these techniques are highly specific, they require highly skilled health workers and have the inherent risks of all invasive procedures, such as pain and risk of bacterial and fungal super-infection. Therefore, it is essential to reduce discomfort, potential infection and scarring caused by invasive diagnostic approaches especially for children. In this report, we present a novel non-invasive method, that is painless, rapid and user-friendly, using sequential tape strips for sampling and isolation of DNA from the surface of active and healed skin lesions of CL patients. A total of 119 patients suspected of suffering from cutaneous leishmaniasis with different clinical manifestations were recruited and samples were collected both from their lesions and from uninfected areas. In addition, 15 fungal-infected lesions and 54 areas of healthy skin were examined. The duration of sampling is short (less than one minute and species identification by PCR is highly specific and sensitive. The sequential tape stripping sampling method is a sensitive, non-invasive and cost-effective alternative to traditional diagnostic assays and it is suitable for field studies as well as for use in health care centers.

  2. Ophthalmology research protocol, Hiroshima - Nagasaki

    Energy Technology Data Exchange (ETDEWEB)

    Miller, R J; Fujino, Tadashi; Nefzger, M D

    1964-05-21

    Several large ophthalmic studies have been made at ABCC. However, all preceded the final identification and definition of the Master Sample which unifies the three present major research studies, and T57D estimates were not available. For these reasons it seemed highly desirable to undertake another ophthalmic study which would both relate to the present program and utilize available dose information. Consequently, in 1962 a consultant in ophthalmology, Dr. P.J. Leinfelder visited ABCC to acquaint himself with the ABCC program and facilities, and he prepared the broad plan for this study. The present document describes the detailed working program which developed from this initial plan. For the period 1963 to 1964, investigation will be directed towards detection and evaluation of the following possible late effects of exposure to ionizing radiation: lens opacities; accelerated aging; and decreased acuity. 43 references, 1 figure, 4 tables.

  3. Application of RNB for high sensitive wear diagnostics in medicine technique and industry

    International Nuclear Information System (INIS)

    Fehsenfeld, P.; Eifrig, C.; Kubat, R.

    2002-01-01

    The RTM--Radionuclide Technique in Mechanical engineering--is now extended to the solution of world wide problems in medicine technique (prosthetics), and in development of modern materials (synthetic materials, ceramics, hard coatings, etc.) and their industrial application. RNB--Radioactive Nuclear Beams of 7 Be or 22 Na--may enable the required extreme thin radioactive surface labeling (several micrometers) of synthetic materials for wear measurements without producing radiation damages of influence to the wear properties of the material. The function principle and special properties of the RTM on-line wear diagnostics and its components, the measurement methods, the radioactive surface labeling, and the measurement instruments are explained. The quality features of a 7 Be and 22 Na-beam for RTM application are specified

  4. Iterative reconstruction technique with reduced volume CT dose index: diagnostic accuracy in pediatric acute appendicitis

    Energy Technology Data Exchange (ETDEWEB)

    Didier, Ryne A. [Oregon Health and Science University, Department of Diagnostic Radiology, DC7R, Portland, OR (United States); Vajtai, Petra L. [Oregon Health and Science University, Department of Pediatrics, Portland, OR (United States); Oregon Health and Science University, Department of Diagnostic Radiology, DC7R, Portland, OR (United States); Hopkins, Katharine L. [Oregon Health and Science University, Department of Diagnostic Radiology, DC7R, Portland, OR (United States); Oregon Health and Science University, Department of Pediatrics, Portland, OR (United States)

    2014-07-05

    Iterative reconstruction technique has been proposed as a means of reducing patient radiation dose in pediatric CT. Yet, the effect of such reductions on diagnostic accuracy has not been thoroughly evaluated. This study compares accuracy of diagnosing pediatric acute appendicitis using contrast-enhanced abdominopelvic CT scans performed with traditional pediatric weight-based protocols and filtered back projection reconstruction vs. a filtered back projection/iterative reconstruction technique blend with reduced volume CT dose index (CTDI{sub vol}). Results of pediatric contrast-enhanced abdominopelvic CT scans done for pain and/or suspected appendicitis were reviewed in two groups: A, 192 scans performed with the hospital's established weight-based CT protocols and filtered back projection reconstruction; B, 194 scans performed with iterative reconstruction technique and reduced CTDI{sub vol}. Reduced CTDI{sub vol} was achieved primarily by reductions in effective tube current-time product (mAs{sub eff}) and tube peak kilovoltage (kVp). CT interpretation was correlated with clinical follow-up and/or surgical pathology. CTDI{sub vol}, size-specific dose estimates (SSDE) and performance characteristics of the two CT techniques were then compared. Between groups A and B, mean CTDI{sub vol} was reduced by 45%, and mean SSDE was reduced by 46%. Sensitivity, specificity and diagnostic accuracy were 96%, 97% and 96% in group A vs. 100%, 99% and 99% in group B. Accuracy in diagnosing pediatric acute appendicitis was maintained in contrast-enhanced abdominopelvic CT scans that incorporated iterative reconstruction technique, despite reductions in mean CTDI{sub vol} and SSDE by nearly half as compared to the hospital's traditional weight-based protocols. (orig.)

  5. Evidence-based practice instruction by faculty members and librarians in North American optometry and ophthalmology programs.

    Science.gov (United States)

    MacDonald, Katherine A; Hrynchak, Patricia K; Spafford, Marlee M

    2014-07-01

    North American optometry and ophthalmology faculty members and vision science librarians were surveyed online (14% response rate) about teaching evidence-based practice (EBP). Similar to studies of other health care programs, all five EBP steps (Ask, Acquire, Appraise, Apply, Assess) were taught to varying degrees. Optometry and ophthalmology EBP educators may want to place further emphasis on (1) the Apply and Assess steps, (2) faculty- and student-generated questions and self-assessment in clinical settings, (3) online teaching strategies, (4) programmatic integration of EBP learning objectives, and (5) collaboration between faculty members and librarians.

  6. Recent developments in diagnostic imaging techniques and management for acute pulmonary embolism. Multicenter registry by the Japanese Society of Pulmonary Embolism Research

    International Nuclear Information System (INIS)

    Sakuma, Masahito; Okada, Osamu; Nakamura, Mashio

    2003-01-01

    There are many reports on the diagnosis and management of acute pulmonary embolism (APE), but there have been no investigations concerning the actual conditions in which recent developments in diagnostic imaging techniques and therapies have been applied in clinical practice. The present study was designed to investigate the changes in diagnostic imaging techniques and therapies for APE. Three hundred and nine APE patients diagnosed during January 1994-October 1997 (Group 1) were compared with 257 APE patients diagnosed during November 1997-October 2000 (Group 2) in terms of the diagnostic imaging techniques and therapies for APE. Compared with Group 1, pulmonary angiography and contrast-enhanced computed tomography were more frequently performed for diagnosis in Group 2 [45.3% vs 56.8% (p=0.0069) and 13.9% vs 57.6% (p<0.0001), respectively]. Heparin and vena cava filter were used more often in Group 2 [74.4% vs 82.1% (p=0.033) and 18.4% vs 33.9% (p<0.0001), respectively]. The frequency of thrombolytic therapy was unchanged between the two groups. Warfarin use in discharged patients increased from 71.9% to 83.8% (p=0.0022). However, the examination rates for deep vein thrombosis (DVT) were low (60.8% in Group 1 and 65.4% in Group 2, p=0.29) and unchanged using any imaging techniques. The diagnostic imaging techniques for APE increased in variety and the management has improved, while the diagnosis for DVT remains unchanged. (author)

  7. [International relationships in ophthalmology in the German Democratic Republic (GDR)].

    Science.gov (United States)

    Jähne, M

    2017-09-01

    International relationships in ophthalmology in the former German Democratic Republic (GDR) were directed by the government and predominantly promoted relationships to socialist countries in Eastern Europe. The lack of freedom of travel, restrictions of import for scientific journals and general prevention of contacts by the State security service led to a stagnation in daily practice and in research, mainly from 1961 until 1989.

  8. Diagnostics

    DEFF Research Database (Denmark)

    Donné, A.J.H.; Costley, A.E.; Barnsley, R.

    2007-01-01

    of the measurements—time and spatial resolutions, etc—will in some cases be more stringent. Many of the measurements will be used in the real time control of the plasma driving a requirement for very high reliability in the systems (diagnostics) that provide the measurements. The implementation of diagnostic systems...... on ITER is a substantial challenge. Because of the harsh environment (high levels of neutron and gamma fluxes, neutron heating, particle bombardment) diagnostic system selection and design has to cope with a range of phenomena not previously encountered in diagnostic design. Extensive design and R......&D is needed to prepare the systems. In some cases the environmental difficulties are so severe that new diagnostic techniques are required. The starting point in the development of diagnostics for ITER is to define the measurement requirements and develop their justification. It is necessary to include all...

  9. Ophthalmologic outcome after third cranial nerve palsy or paresis in childhood.

    Science.gov (United States)

    Mudgil, A V; Repka, M X

    1999-02-01

    The purpose of this study was to evaluate the causes and ophthalmologic outcome of oculomotor nerve palsy or paresis in children younger than 8 years of age. Patients evaluated between 1985 and 1997 were retrospectively reviewed. Data analyzed included vision, residual strabismus after surgery, aberrant reinnervation, binocular function, and anisometropia. Long-term outcome was assessed in patients followed-up longer than 6 months. Forty-one patients were identified. The most frequent causes were congenital (39%), traumatic (37%), and neoplastic (17%). Visual acuities were reduced in 71% of patients at the time of the initial visit. Long-term outcome could be assessed in 20 of the 41 patients (49%), with a mean follow-up of 3.6 years (range, 0.5 to 13 years). Visual acuities were reduced because of amblyopia in 35% and nonamblyopic factors in 25% of patients in the long-term outcome group at last follow-up. The best response to amblyopia therapy was in the congenital group, in which all patients improved to normal visual acuity. Strabismus surgery was performed on 8 of 20 children (40%) followed-up, none of whom demonstrated measurable stereopsis after operation despite improved alignment. Aberrant reinnervation was present in 9 of 20 patients (45%). Only 3 patients fully recovered from their oculomotor nerve injuries, and these were the only patients to regain measurable stereopsis. The causes in those 3 patients were congenital, traumatic, and neoplastic. Oculomotor nerve palsy/paresis is associated with poor visual and sensorimotor outcome in children younger than 8 years of age. The best ophthalmologic outcome was in the resolved cases (3 of 20; 15%). Amblyopia therapy was most effective with congenital causes, but treatment results were poor with other causes. Young children with posttraumatic and postneoplastic oculomotor nerve injuries demonstrated the worst ophthalmologic outcomes.

  10. Refractive surgery: Is the new small-incision lenticule extraction (SMILE) technique equal to or better than the standard flap-and-ablation (FS-LASIK) technique for treating high-degree myopia?

    DEFF Research Database (Denmark)

    Hansen, Rasmus Søgaard; Lyhne, Niels; Grauslund, Jakob

    Field: Ophthalmology Introduction: Corneal laser surgery for myopia (nearsightedness) is one of the most performed surgical procedures today. FS-LASIK has been the dominating surgical technique for almost two decades, but a shift to the new less invasive SMILE technique might be underway. However...... the literature on SMILE is sparse, especially for high-degree myopia (six or more dioptres (D)). We hypothesize that the accuracy, efficacy, stability and safety after SMILE is equal to or better than FS-LASIK up to three months post-operatively for high-degree myopia. Methods: Retrospective study of 1214 eyes...... treated with SMILE or FS-LASIK for high-degree myopia from 2011-2013 at the Department of Ophthalmology, Odense University Hospital, Denmark. Inclusion criteria: Best spectacle-corrected visual acuity (BSCVA) of 20/25 or better on Snellen chart, and no other ocular condition than high-degree myopia...

  11. [Results of an internet-based survey amongst members of the German Ophthalmological Society concerning postmortem cornea donation].

    Science.gov (United States)

    Uhlig, C E; Promesberger, J; Hirschfeld, G; Koch, R; Reinhard, T; Seitz, B

    2012-12-01

    Analysis of willingness for postmortem cornea donation by professionals in ophthalmology and their motives in favor of or against donation. 3887 members of the German Ophthalmological Society received an anonymous questionnaire concerning sociodemographic background, physical health, experiences with organ explantation and their former engagement and motives concerning organ and cornea donation. 722 of the questionnaires were partially and 533 completely answered with an average willingness for cornea donation of 79.4%. Significant parameters for cornea donation were gender, former experience with organ explantation, ophthalmological health and fear of false diagnosis of brain death, worse medical treatment or organ commercialization. Of the participants 53.9% suggested the internet as a favorite source of information in this matter. The factors which had a significant impact on cornea donation in this survey seem to be mainly a result of insufficient information. Detailed information regarding this topic should preferentially be presented on internet pages of professional societies and could probably increase donation approval of DOG members.

  12. Towards diagnostics for a fusion reactor

    International Nuclear Information System (INIS)

    Costley, A. E.

    2009-01-01

    The requirements for measurements on modern tokamak fusion plasmas are outlined, and the techniques and systems used to make the measurements, usually referred to as 'diagnostics', are introduced. The basics of three particular diagnostics - magnetics, neutron systems and a laser based optical system - are outlined as examples of modern diagnostic systems, and the implementation of these diagnostics on a current tokamak (JET) are described. The next major step in magnetic confinement fusion is the construction and operation of the International Thermonuclear Experimental Reactor (ITER), which is a joint project of China, Europe, Japan, India, Korea, the Russian Federation, and the United States. Construction has begun in Cadarache, France. It is expected that ITER will operate at the 500 MW level. Because of the harsh environment in the vacuum vessel where many diagnostic components are located, the development of diagnostics for ITER is a major challenge - arguably the most difficult challenge ever undertaken in the field of diagnostics. The main elements in the diagnostic step are outlined using the three chosen techniques as examples. Finally, the step beyond ITER to a demonstration reactor, DEMO, that is expected to produce several GWs of fusion power is considered and the impact on diagnostics outlined. It is shown that the applicability and development steps needed for the individual diagnostics techniques will differ. The challenges for DEMO diagnostics are substantial and a dedicated effort should be made to find and develop new techniques, and especially techniques appropriate to the DEMO environment. It is argued that the limitations and difficulties in diagnostics should be a consideration in the optimization and designs of DEMO. (author)

  13. Low-level therapy in ophthalmology

    Science.gov (United States)

    Pankov, O. P.

    1999-07-01

    Extremely slow introduction of low-level laser therapy into the practice of ophthalmologists is restricted by the lack of good methodological recommendation and modern equipment adopted to the needs of ophthalmology. The most perspective is considered to be further improvement of the methods and the elaboration of the medical equipment, working in several wave bands, combined with magnetotherapy and working with the use of various modes of the modulation of the intensity of the luminous flux. It may be asserted that unlike the mode of continuous radiation, in some cases, the effectiveness of the treatment increases when the modulated light with the frequency of one to a few tens HZ is used. Moreover, the methods are being elaborated, when the modulation frequency of laser light and the biorhythms of man physiologic parameters are synchronized. Very perspective seems the computerization of the treatment process with the simultaneous electrophysiological control of the condition of visual functions.

  14. Intercomparison of techniques for inspection and diagnostics of heavy water reactor pressure tubes. Determination of hydrogen concentration and blister characterization

    International Nuclear Information System (INIS)

    2009-03-01

    Heavy water reactors (HWRs) comprise significant numbers of today's operating nuclear power plants, and more are under construction. Efficient and accurate inspection and diagnostic techniques for various reactor components and systems, especially pressure tubes, are an important factor in ensuring reliable and safe plant operation. To foster international collaboration in the efficient and safe use of nuclear power, the IAEA conducted a Coordinated Research Project (CRP) on Intercomparison of Techniques for HWR Pressure Tube Inspection and Diagnostics. This CRP was carried out within the framework of the IAEA's Technical Working Group on Advanced Technologies for HWRs (the TWG-HWR). The TWG-HWR is a group of experts nominated by their governments and designated by the IAEA to provide advice and to support implementation of IAEA's project on advanced technologies for HWRs. The objective of the CRP was to compare non-destructive inspection and diagnostic techniques, in use and being developed, for structural integrity assessment of HWR pressure tubes. During the first phase of this CRP participants investigated the capability of different techniques to detect and characterize flaws. During the second phase participants collaborated to detect and characterize hydride blisters and to determine the hydrogen concentration in zirconium alloys. The intention was to identify the most effective pressure tube inspection and diagnostic methods and to identify further development needs. The organizations which participated in phase 2 of this CRP are: - Comision Nacional de Energia Atomica (CNEA), Argentina; - Atomic Energy of Canada Ltd. (AECL), Chalk River Laboratories (CRL), Canada; - Bhabha Atomic Research Centre (BARC), India; - Korea Atomic Energy Research Institute (KAERI), Republic of Korea; - National Institute for Research and Development for Technical Physics (NIRDTP), Romania; - Nuclear Non-Destructive Testing Research and Services (NNDT), Romania. IAEA-TECDOC-1499

  15. Imaging nuclear medicine techniques for diagnostic evaluation of arterial hypertension. Bildgebende nuklearmedizinische Diagnostik bei arterieller Hypertonie

    Energy Technology Data Exchange (ETDEWEB)

    Eisenberg, B M; Linss, G

    1989-01-01

    Arterial hypertension may be caused by a malfunction of organs and in turn may lead to secondary organic lesions. Modern diagnostic nuclear medicine is applied for function studies in order to detect or exclude secondary hypertension and functional or perfusion disturbances due to hypertension, or to assess and follow up hemodynamic conditions and cardiac functions prior to and during therapy. The article presents a survey of imaging diagnostic nuclear medicine techniques for the eamination of the heart, the brain, the kidneys and endocrine glands in patients with arterial hypertension, discussing the methods with a view to obtainable information, limits of detection, and indications. (orig.).

  16. Development of a diagnostic technique based on Cherenkov effect for measurements of fast electrons in fusion devices

    Energy Technology Data Exchange (ETDEWEB)

    Plyusnin, V. V.; Duarte, P.; Fernandes, H.; Silva, C. [Association Euratom/IST, Instituto de Plasmas e Fusao Nuclear, Instituto Superior Tecnico, Universidade Tecnica de Lisboa, Av. Rovisco Pais, 1049-001 Lisboa (Portugal); Jakubowski, L.; Zebrowski, J.; Malinowski, K.; Rabinski, M.; Sadowski, M. J. [National Centre for Nuclear Research (NCBJ), 7 Andrzeja Soltana Str., 05-400 Otwock (Poland)

    2012-08-15

    A diagnostic technique based on the Cherenkov effect is proposed for detection and characterization of fast (super-thermal and runaway) electrons in fusion devices. The detectors of Cherenkov radiation have been specially designed for measurements in the ISTTOK tokamak. Properties of several materials have been studied to determine the most appropriate one to be used as a radiator of Cherenkov emission in the detector. This technique has enabled the detection of energetic electrons (70 keV and higher) and the determination of their spatial and temporal variations in the ISTTOK discharges. Measurement of hard x-ray emission has also been carried out in experiments for validation of the measuring capabilities of the Cherenkov-type detector and a high correlation was found between the data of both diagnostics. A reasonable agreement was found between experimental data and the results of numerical modeling of the runaway electron generation in ISTTOK.

  17. Estimating the burden of pneumococcal pneumonia among adults: a systematic review and meta-analysis of diagnostic techniques.

    Directory of Open Access Journals (Sweden)

    Maria A Said

    Full Text Available Pneumococcal pneumonia causes significant morbidity and mortality among adults. Given limitations of diagnostic tests for non-bacteremic pneumococcal pneumonia, most studies report the incidence of bacteremic or invasive pneumococcal disease (IPD, and thus, grossly underestimate the pneumococcal pneumonia burden. We aimed to develop a conceptual and quantitative strategy to estimate the non-bacteremic disease burden among adults with community-acquired pneumonia (CAP using systematic study methods and the availability of a urine antigen assay.We performed a systematic literature review of studies providing information on the relative yield of various diagnostic assays (BinaxNOW® S. pneumoniae urine antigen test (UAT with blood and/or sputum culture in diagnosing pneumococcal pneumonia. We estimated the proportion of pneumococcal pneumonia that is bacteremic, the proportion of CAP attributable to pneumococcus, and the additional contribution of the Binax UAT beyond conventional diagnostic techniques, using random effects meta-analytic methods and bootstrapping. We included 35 studies in the analysis, predominantly from developed countries. The estimated proportion of pneumococcal pneumonia that is bacteremic was 24.8% (95% CI: 21.3%, 28.9%. The estimated proportion of CAP attributable to pneumococcus was 27.3% (95% CI: 23.9%, 31.1%. The Binax UAT diagnosed an additional 11.4% (95% CI: 9.6, 13.6% of CAP beyond conventional techniques. We were limited by the fact that not all patients underwent all diagnostic tests and by the sensitivity and specificity of the diagnostic tests themselves. We address these resulting biases and provide a range of plausible values in order to estimate the burden of pneumococcal pneumonia among adults.Estimating the adult burden of pneumococcal disease from bacteremic pneumococcal pneumonia data alone significantly underestimates the true burden of disease in adults. For every case of bacteremic pneumococcal pneumonia

  18. Comparison of advanced optical imaging techniques with current otolaryngology diagnostics for improved middle ear assessment (Conference Presentation)

    Science.gov (United States)

    Nolan, Ryan M.; Shelton, Ryan L.; Monroy, Guillermo L.; Spillman, Darold R.; Novak, Michael A.; Boppart, Stephen A.

    2016-02-01

    Otolaryngologists utilize a variety of diagnostic techniques to assess middle ear health. Tympanometry, audiometry, and otoacoustic emissions examine the mobility of the tympanic membrane (eardrum) and ossicles using ear canal pressure and auditory tone delivery and detection. Laser Doppler vibrometry provides non-contact vibrational measurement, and acoustic reflectometry is used to assess middle ear effusion using sonar. These technologies and techniques have advanced the field beyond the use of the standard otoscope, a simple tissue magnifier, yet the need for direct visualization of middle ear disease for superior detection, assessment, and management remains. In this study, we evaluated the use of portable optical coherence tomography (OCT) and pneumatic low-coherence interferometry (LCI) systems with handheld probe delivery to standard tympanometry, audiometry, otoacoustic emissions, laser Doppler vibrometry, and acoustic reflectometry. Comparison of these advanced optical imaging techniques and current diagnostics was conducted with a case study subject with a history of unilateral eardrum trauma. OCT and pneumatic LCI provide novel dynamic spatiotemporal structural data of the middle ear, such as the thickness of the eardrum and quantitative detection of underlying disease pathology, which could allow for more accurate diagnosis and more appropriate management than currently possible.

  19. Evaluation of the anterior chamber angle in glaucoma: a report by the american academy of ophthalmology.

    Science.gov (United States)

    Smith, Scott D; Singh, Kuldev; Lin, Shan C; Chen, Philip P; Chen, Teresa C; Francis, Brian A; Jampel, Henry D

    2013-10-01

    gonioscopy. Longitudinal studies are needed to validate the diagnostic significance of the parameters measured by these instruments for prospectively identifying individuals at risk for PAC. Proprietary or commercial disclosure may be found after the references. Copyright © 2013 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  20. Picosecond high power laser systems and picosecond diagnostic technique in laser produced plasma

    International Nuclear Information System (INIS)

    Kuroda, Hiroto; Masuko, H.; Maekawa, Shigeru; Suzuki, Yoshiji; Sugiyama, Masaru.

    1979-01-01

    Highly repetitive, high power YAG and Glass laser systems have been developed and been successfully used for the studies of laser-plasma interactions. Various picosecond diagnostic techniques have been developed for such purposes in the regions from optical to X-ray frequency. Recently highly sensitive X-ray (1 - 10 KeV) streak camera for highly repetitive operations have been developed. Preliminary experiment shows the achievement of 28ps temporal resolution (100μm slit) and good sensitivity with detectable minimum number of 10E3-1KeV photons/shot/slit area. (author)

  1. The evaluation of the irradiation of medical team in critical X-ray diagnostic techniques

    Energy Technology Data Exchange (ETDEWEB)

    Markovic, S; Pavlovic, R [Inst. of Nuclear Science Vinca, Belgrade (Yugoslavia). Radiation and Environmental Protection Lab.; Boreli, F [Fac. of Electrical Engineering, Belgrade (Yugoslavia)

    1996-12-31

    A good realized assessment of the irradiation for any exposed group of population serves as the base for the radiation protection measures (emergency radiation preparedness, radiation protection optimization etc.). This is especially important, by the radiation protection point of view, in contrast X-ray diagnostic techniques - angiographies. This paper presents the way for the realization of the medical team irradiation assessment, based on originally derived simple equations for the scattered radiation field around patient. (author) 1 fig., 3 figs.

  2. A comparison of undergraduate clinical ophthalmology learning methods: smart phone television display versus slit-lamp teaching telescope.

    Science.gov (United States)

    Wenting, Sandy Zhou; Samin, Margaret Million; Sanjay, Srinivasan; Neelam, Kumari; Shibli, Khalil; Chang, Su; Cheng, Jason

    2017-08-01

    To compare medical students' preference of smart phone television display (SPTD) to a slit-lamp teaching telescope (SLTT) in undergraduate clinical ophthalmology education. This is a randomized, crossover, comparative study. Pairs of medical students were randomly assigned to 2 teaching sessions using either SPTD first followed by SLTT or in reverse order. Students were asked to give feedback on the 2 teaching devices by answering 6 questions using a numeric rating score from 1 to 10. All participating students were sent the results of the study 1 month after the completion of the study and were asked to reflect upon the outcome. Thirty-eight students were recruited. The overall satisfaction scores were significantly higher for SPTD than SLTT (8.6 ± 1.4 vs 7.5 ± 1.0, p teaching. Our study has demonstrated that the utility of SPTD as a teaching aid can significantly increase the satisfaction of undergraduate medical students during their ophthalmology attachment. It offers specific practical advantages in teaching medical students over the traditional SLTT. Copyright © 2017 Canadian Ophthalmological Society. Published by Elsevier Inc. All rights reserved.

  3. OPHTHALMOLOGICAL AND RADIOLOGICAL PICTURE OF CROUZON SYNDROME – A CASE REPORT

    Directory of Open Access Journals (Sweden)

    Rade R. Babić

    2009-04-01

    Full Text Available Crouzon syndrome (CS accounts for about 4.8% of all cases of craniosynostosis. Crouzon syndrome occurs in approximately 1 per 25.000 births worldwide. It may be transmitted as an autosomal dominant genetic condition, but 25% of cases represent a fresh mutation. There is no race or sex predilection. The appearance of an infant with CS can vary in severity from mild presentation with subtle midface characteristics to severe forms with multiple cranial sutures, fused and marked midface and eye problems.A ten-year-old girl suspected to have congenital glaucoma was sent to a consultative examination to the Ophthalmology Clinic, CC Nis. The very appearance of the girl indicated the diagnosis – Crouzon syndrome, which was confirmed by ophthalmological and radiological examinations. The patient was referred to the ophthalmologist in charge for further attendance and was recommended to undergo a surgical treatment by a maxillofacial surgeon.Exophtalmus, hypertelorism, divergent strabismus, hypermetropy, head, orbit and jaw deformities, extremely illustrative, mostly rarely seen in everday practice, are the elements of the clinical picture of Crouzon syndrome. It deserves our attention, taking into consideration ocular complications and multifactorial purblindness which it causes.

  4. Noninvasive Diagnostic Technique in Stenotic Coronary Atherosclerosis

    Directory of Open Access Journals (Sweden)

    A. Yu. Vasilyev

    2005-01-01

    Full Text Available Objective: to determine the sensitivity and specificity of combined stress echocardiography (EchoCG using dipyri-damole and dobutamine in diagnosing and defining the extent of stenotic coronary lesions in coronary heart disease (CHD in a group of critically ill patients who are unable to perform a physical exercise.Materials and methods: the study included 57 male patients with suspected acute coronary syndrome who underwent stress EchoCG using dipyridamole in high doses in combination with dobutamine, as well as coronary angiography.Results: stress EchoCG could bring up to the diagnostic criteria in all the patients, of whom 9 patients were found at coronary angiography to have no coronary lesion, 34 and 14 patients had one- and many-vessel lesions, respectively. The sensitivity and specificity of combined stress EchoCG were significantly higher than those of EchoCG used in the diagnosis of CHD.Conclusion: stress EchoCG using dipyridamole in combination with dobutamine is a highly informative safe noninvasive technique for diagnosing CHD, its helps to identify patients with atypical acute coronary syndrome and to form a group of patients to be subject to urgent coronarography and angiosurgical intervention. The pattern of segmental contractile disorders at the height of exercise during combined stress Echo-CG makes it possible to define the site of stenotic coronary atherosclerosis with 97.3% sensitivity and to diagnose many-vessel lesion with 100% sensitivity and 100%specificity.

  5. Evidence-based medical research on diagnostic criteria and screening technique of vascular mild cognitive impairment

    Directory of Open Access Journals (Sweden)

    Xia-wei LIU

    2015-07-01

    Full Text Available Background Vascular mild cognitive impairment (VaMCI is the prodromal syndrome of vascular dementia (VaD and key target for drug treatment. There is controversy over the diagnostic criteria and screening tools of VaMCI, which affects its clinical diagnosis. This paper aims to explore the clinical features, diagnostic criteria and screening technique of VaMCI.  Methods Taking "vascular mild cognitive impairment OR vascular cognitive impairment no dementia" as retrieval terms, search in PubMed database from January 1997 to March 2015 and screen relevant literatures concerning VaMCI. According to Guidance for the Preparation of Neurological Management Guidelines revised by European Federation of Neurological Societies (EFNS in 2004, evidence grading was performed on literatures. Results A total of 32 literatures in English were selected according to inclusion and exclusion criteria, including 3 guidelines and consensus and 29 clinical studies. Seven literatures (2 on Level Ⅰ, 5 on Level Ⅱ studied on neuropsychological features in VaMCI patients and found reduced processing speed and executive function impairment were main features. Two literatures reported the diagnostic criteria of VaMCI, including VaMCI criteria published by American Heart Association (AHA/American Stroke Association (ASA in 2011 and "Diagnostic Criteria for Vascular Cognitive Disorders" published by International Society for Vascular Behavioral and Cognitive Disorders (VASCOG in 2014. Fifteen literatures (4 on LevelⅠ, 11 on Level Ⅱ described the diagnostic criteria of VaMCI used in clinical research, from which 6 operational diagnostic items were extracted. Fourteen literatures (4 on Level Ⅰ, 10 on Level Ⅱ described neuropsychological assessment tools for VaMCI screening, and found the 5-minute protocol recommended by National Institute of Neurological Disorders and Stroke-Canadian Stroke Network (NINDS-CSN was being good consistency with other neuropsychological

  6. Use of health care claims data to study patients with ophthalmologic conditions.

    Science.gov (United States)

    Stein, Joshua D; Lum, Flora; Lee, Paul P; Rich, William L; Coleman, Anne L

    2014-05-01

    To describe what information is or is not included in health care claims data, provide an overview of the main advantages and limitations of performing analyses using health care claims data, and offer general guidance on how to report and interpret findings of ophthalmology-related claims data analyses. Systematic review. Not applicable. A literature review and synthesis of methods for claims-based data analyses. Not applicable. Some advantages of using claims data for analyses include large, diverse sample sizes, longitudinal follow-up, lack of selection bias, and potential for complex, multivariable modeling. The disadvantages include (a) the inherent limitations of claims data, such as incomplete, inaccurate, or missing data, or the lack of specific billing codes for some conditions; and (b) the inability, in some circumstances, to adequately evaluate the appropriateness of care. In general, reports of claims data analyses should include clear descriptions of the following methodological elements: the data source, the inclusion and exclusion criteria, the specific billing codes used, and the potential confounding factors incorporated in the multivariable models. The use of claims data for research is expected to increase with the enhanced availability of data from Medicare and other sources. The use of claims data to evaluate resource use and efficiency and to determine the basis for supplementary payment methods for physicians is anticipated. Thus, it will be increasingly important for eye care providers to use accurate and descriptive codes for billing. Adherence to general guidance on the reporting of claims data analyses, as outlined in this article, is important to enhance the credibility and applicability of findings. Guidance on optimal ways to conduct and report ophthalmology-related investigations using claims data will likely continue to evolve as health services researchers refine the metrics to analyze large administrative data sets. Copyright

  7. Patient satisfaction with wait times at an emergency ophthalmology on-call service.

    Science.gov (United States)

    Chan, Brian J; Barbosa, Joshua; Moinul, Prima; Sivachandran, Nirojini; Donaldson, Laura; Zhao, Lily; Mullen, Sarah J; McLaughlin, Christopher R; Chaudhary, Varun

    2018-04-01

    To assess patient satisfaction with emergency ophthalmology care and determine the effect provision of anticipated appointment wait time has on scores. Single-centre, randomized control trial. Fifty patients triaged at the Hamilton Regional Eye Institute (HREI) from November 2015 to July 2016. Fifty patients triaged for next-day appointments at the HREI were randomly assigned to receive standard-of-care preappointment information or standard-of-care information in addition to an estimated appointment wait time. Patient satisfaction with care was assessed postvisit using the modified Judgements of Hospital Quality Questionnaire (JHQQ). In determining how informing patients of typical wait times influenced satisfaction, the Mann-Whitney U test was performed. As secondary study outcomes, we sought to determine patient satisfaction with the intervention material using the Fisher exact test and the effect that wait time, age, sex, education, mobility, and number of health care providers seen had on satisfaction scores using logistic regression analysis. The median JHQQ response was "very good" (4/5) and between "very good" and "excellent" (4.5/5) in the intervention and control arms, respectively. There was no difference in patient satisfaction between the cohorts (Mann-Whitney U = 297.00, p = 0.964). Logistic regression analysis demonstrated that wait times influenced patient satisfaction (OR = 0.919, 95% CI 0.864-0.978, p = 0.008). Of the intervention arm patients, 92.0% (N = 23) found the preappointment information useful, whereas only 12.5% (N = 3) of the control cohort patients noted the same (p < 0.001). Provision of anticipated wait time information to patients in an emergency on-call ophthalmology clinic did not influence satisfaction with care as captured by the JHQQ. Copyright © 2018 Canadian Ophthalmological Society. Published by Elsevier Inc. All rights reserved.

  8. Angiography - interventional diagnostic applications

    International Nuclear Information System (INIS)

    Schild, H.

    1994-01-01

    The angiography system is very different from the other systems used in diagnostic radiology. The invasivity of angiography requires special, high standards in theoretical and practical training and experience both of beginners and experienced personnel. This textbook fully meets the demand for in-depth and exhaustive information, as it presents: - The fundamentals and techniques of angiography, the vascular anatomy, and many hints and tips of great help in practice. - A comprehensive survey of diagnostic problems and examination approaches, including neuro-angiography, with 221 reproductions of original angiographs, and additional schematic representations. - A special chapter devoted to indication and relevant techniques for the major vascular interventional examinations. - A great number of tables explain at a glance standard examination techniques, indications and diagnostic criteria. (orig./CB) [de

  9. [Platforms are needed for innovative basic research in ophthalmology].

    Science.gov (United States)

    Wang, Yi-qiang

    2012-07-01

    Basic research poses the cornerstone of technical innovation in all lines including medical sciences. Currently, there are shortages of professional scientists as well as technical supporting teams and facilities in the field of basic research of ophthalmology and visual science in China. Evaluation system and personnel policies are not supportive for innovative but high-risk-of-failure research projects. Discussion of reasons and possible solutions are given here to address these problems, aiming at promoting buildup of platforms hosting novel and important basic research in eye science in this country.

  10. PHYSICO-CHEMICAL CHARACTERIZATION OF POLYMERIC FILMS USED IN OPHTHALMOLOGY

    Directory of Open Access Journals (Sweden)

    Ioan Emanuel STAVARACHE

    2017-03-01

    Full Text Available The aim of the present work was to characterize the surface properties of (polymethylmethacrylate (PMMA foils used in ophathalmological applications. Thus, the morphology, chemical composition and surface energy of these PMMA foils are analyzed, by specific measurements, at the interface with different test liquids of interest in ophthalmology, i.e. distilled H2 O, physiological serum and ophthalmic solution of ReNu Multiplus, used for contact lens cleaning, hydration and disinfection. Also, a solution of Nostamine, known as a drug used in eye irritation and conjunctival inflammation, was tested.

  11. Exploration and deliberation of on-job postgraduates training in clinical ophthalmology

    Directory of Open Access Journals (Sweden)

    Wei-Jia Dai

    2014-07-01

    Full Text Available With the diversified development in training clinical students, an impeccable system in clinical on-job postgraduates training has been established. It has been being an important problem for colleges and tutors to improve the quality in the postgraduates training program in the specialty of ophthalmology. This paper analyzed the problems in the training of clinical postgraduates and explored the ways to resolve the problems.

  12. Effects of hand massage on anxiety in patients undergoing ophthalmology surgery using local anesthesia

    Directory of Open Access Journals (Sweden)

    Jafar Rafiei Kiasari

    2012-08-01

    Full Text Available Introduction: Anxiety is a common disorder in patients before surgery. Inappropriately managed anxiety can cause psychological and physiological reactions and will affect the process of surgery and recovery. Therefore, this study examined the effects of hand mas-sage on anxiety in patients undergoing ophthalmology surgery using local anesthesia. Methods: In this interventional study, 52 patients who were supposed to undergo oph-thalmology surgery using local anesthesia were studied. Patients were randomly as-signed to two groups of intervention, who received hand massage before surgery (n = 27 and control (n = 25. Massaging lasted for 5 minutes (2.5 minutes on each hand before surgery. Stroking and scrubbing methods were performed by 2 trained research-ers. Anxiety level, blood pressure, heart rate, and respiratory rate were measured before and after the intervention in both groups. Anxiety was evaluated using Spielberger State-Trait Anxiety Inventory. Data was analyzed by chi-square, independent samples t-test, and paired t-test. Results: There were no significant differences in mean anxiety, systolic blood pressure, diastolic blood pressure, heart rate, and respiratory rate between the two groups before the intervention (p > 0.05. However, there was a significant differenc in the mean stress level between the two groups after the intervention (p 0.05. Conclusion: Our findings suggested that 5 minutes of hand massage before ophthalmology surgery (under local anesthesia could reduce anxiety. Therefore, this method can be used to increase patient comfort and reduce anxiety before surgical interventions.

  13. A general purpose diagnostic technique for marine diesel engines - Application on the main propulsion and auxiliary diesel units of a marine vessel

    International Nuclear Information System (INIS)

    Lamaris, V.T.; Hountalas, D.T.

    2010-01-01

    Diesel engines are widely used in marine applications (i.e. propulsion and auxiliaries) except from a few cases where gas or steam turbines are used. This is the result of their high efficiency, power concentration and reliability compared to other compatible or alternative power sources. The proper and efficient operation of the engines (main engine and diesel generator units) in marine applications is critical, and therefore techniques or systems that determine engine current condition and detect potential faults are extremely important. Furthermore, it is advantageous when such techniques can be applied on different engine configurations and provide reliable results, because on a vessel usually exist diesel engines of different type, i.e. the main propulsion unit is a large low-speed two-stroke diesel engine while the diesel generators are four-stroke medium or high speed engines. In the present work is described and evaluated for the first time the application of an improved diagnostic technique, developed by the authors, on both the main engine and the auxiliary units of a commercial marine vessel. The diagnostic technique is based on a thermodynamic simulation model. The simulation model embedded in the technique has been modified, namely an existing two-zone model is replaced by a multi-zone one. With this modification it is avoided model constant tuning with the operating conditions. This is extremely important for the diagnostic philosophy of the proposed technique. Using data from engine shop tests, the simulation model is calibrated (i.e. model constants are determined) and the engine reference condition is obtained. The simulation model is then used to estimate the current engine condition, using field measurements (i.e. cylinder pressure measurements, periphery data, etc.). From the results it is revealed that the diagnosis method provides detailed information for the operating condition of both engines and the values of parameters that cannot be

  14. Microscopic alterations in silicone tubes surface after application of ophthalmological lubricants

    Directory of Open Access Journals (Sweden)

    Jacqueline Sousa

    2015-02-01

    Full Text Available Objective: To identify microscopic morphological alterations in the surface of silicone tubes used for intubation of the lachrymal system after exposure to ophthalmological lubricants. Methods: Experimental, descriptive and longitudinal study consisted of the application of ophthalmological lubricants in silicone tubes. The tubes were divided in: Group 1 (Cylocort®, 2 (Epitezan®, 3 (Labcaína®, 4 (Liposic®, 5 (Maxinom® and 6 (Vista Gel®. One tube was not exposed to any lubricant, used as control. The tubes were observed and photographed after 2 hours, 30 days, 45 days before and after cleaning the surface and lumen. The following aspects were observed: surface (regularity, transparency, quantity, size and shape of the substances and lumen (obstruction. Results: Control: irregular surface with pores after 2 hours: Group 1 – irregular surface with presence of film; Groups 2, 3 and 5 – abundant and irregular quantity of ointment at the surface; Group 4 – discrete modification at the surface; Group 6 – growth of pigmented (brownish structures with filaments in the lumen, with discrete film in the surface. 30 Days: Groups 1, 4 and 5 – increase of the irregular superficial film; Group 2 – crust with notorious horizontal lines; Group 3 – diminution of the superficial film; Group 4 – crust less evident. Group 6 – increase of the structure seen with 2 hours of exposition, arboriform aspect. Forty-five days pre cleaning: Group 4 – diminution of the surface crust; Group 6 – expansion of the arboriform structure; unaltered findings in other groups. 45 days after cleaning: Groups 1 and 5 – light diminution of the surface crust; Groups 2, 3 and 4 – kept the modifications; Group 6 – the structure inside the lumen was not identified, clear surface, without evidence of film. Conclusions: Microscopic morphological alterations in the surface and lumen of silicone tubes can occur when those remain in contact with determined

  15. Reducing beam shaper alignment complexity: diagnostic techniques for alignment and tuning

    Science.gov (United States)

    Lizotte, Todd E.

    2011-10-01

    Safe and efficient optical alignment is a critical requirement for industrial laser systems used in a high volume manufacturing environment. Of specific interest is the development of techniques to align beam shaping optics within a beam line; having the ability to instantly verify by a qualitative means that each element is in its proper position as the beam shaper module is being aligned. There is a need to reduce these types of alignment techniques down to a level where even a newbie to optical alignment will be able to complete the task. Couple this alignment need with the fact that most laser system manufacturers ship their products worldwide and the introduction of a new set of variables including cultural and language barriers, makes this a top priority for manufacturers. Tools and methodologies for alignment of complex optical systems need to be able to cross these barriers to ensure the highest degree of up time and reduce the cost of maintenance on the production floor. Customers worldwide, who purchase production laser equipment, understand that the majority of costs to a manufacturing facility is spent on system maintenance and is typically the largest single controllable expenditure in a production plant. This desire to reduce costs is driving the trend these days towards predictive and proactive, not reactive maintenance of laser based optical beam delivery systems [10]. With proper diagnostic tools, laser system developers can develop proactive approaches to reduce system down time, safe guard operational performance and reduce premature or catastrophic optics failures. Obviously analytical data will provide quantifiable performance standards which are more precise than qualitative standards, but each have a role in determining overall optical system performance [10]. This paper will discuss the use of film and fluorescent mirror devices as diagnostic tools for beam shaper module alignment off line or in-situ. The paper will also provide an overview

  16. Sensorimotor Characteristics of Neuro-Ophthalmology and Oculo-Plastics Patients.

    Science.gov (United States)

    Christoff, Alex

    2015-01-01

    Certified orthoptists are routinely required, as a standard component of outpatient care, to examine and identify the cause of double vision described by neuro-ophthalmology and oculo-plastics patients. Peer-reviewed articles in the strabismus literature describing the significance of this role of the orthoptists, especially in more complex cases of strabismus, do exist, but are outdated. The importance of creating a differential diagnosis in the understanding of the disease process is a well-recognized component of medical education and modern medicine. This work was a retrospective chart review and descriptive study of the most common clinical characteristics of adult neuro-ophthalmology and oculo-plastics patients seen over a 9-year period by an orthoptist in a large, urban academic institution in the United States. History and clinical data obtained included demographic information; whether the subjects were neuro-ophthalmology or oculo-plastic patients or both; chief complaint; past medical history and associated medical risk factors; past ocular history of strabismus or amblyopia; whether reported diplopia was monocular or binocular; visual acuities; sensorimotor examination and fusion status information; presence or absence of ptosis; pupil size and reactivity; basic accommodative function; orthoptist and physician diagnoses; and suggested treatment of diplopia. Five hundred seventy-five subjects were identified based on inclusion criteria. Racial demographics matched that of the state of Maryland, with the majority of the patients being Caucasian. The minority were of Hispanic origin. Ninety-one percent of the study cohort was referred by the department of neuro-ophthalmology at the institution. Hypertension was a statistically significant medical risk factor for acquired strabismus and diplopia in this adult cohort. Etiology for the strabismus and associated diplopia suggested by the orthoptist was in close agreement with the final diagnosis made by the

  17. The diagnostic value of double-contrast-technique cystography in the evaluation of benign and malignant lesions of the urinary bladder

    International Nuclear Information System (INIS)

    Beyer, D.; Koester, R.; Schuett, H.

    1979-01-01

    Cystography by double-contrast-technique as simple and quick method of evaluating benign and malignant lesions of the urinary bladder is being described. 301 examinations were reviewed and are being discussed in regard to diagnostic value, indication, complication and radiation exposure of this method. A few typical cases are being demonstrated to illustrate the value of this method in the spectrum of other diagnostic methods in the workup of urinary bladder lesions. (orig.) [de

  18. Publication rate of abstracts presented at the 2010 Canadian Ophthalmological Society Annual Meeting.

    Science.gov (United States)

    Basilious, Alfred; Benavides Vargas, Ana Maria; Buys, Yvonne M

    2017-08-01

    To evaluate the publication rate of submitted abstracts accepted for presentation at the 2010 Canadian Ophthalmological Society (COS) Annual Meeting in peer-reviewed journals. A retrospective analysis and literature search of abstracts presented at the 2010 COS Annual Meeting. Abstracts accepted as an oral presentation or poster from the 2010 COS Annual Meeting were tabulated by type of presentation (oral vs poster), subspecialty, study design, number of authors, and principal investigator's institution. A PubMed search was conducted for each abstract by key word, first author, and last author. The year of publication, journal, and impact factor were recorded for identified publications. Publication rate was calculated by type of presentation, subspecialty, study design, number of authors, and institution. A total of 175 abstracts were presented at the 2010 COS Annual Meeting. There were 105 oral (60%) and 70 poster (40%) presentations. The overall publication rate was 45.7%; 49.5% for oral presentations and 40.0% for posters. Cornea (57.6%) and public health (54.5%) had the highest publication rates of all subspecialties. Randomized control trials (71.4%) and cohort studies (70.0%) had higher publication rates than other study designs. Overall, 28.8% of abstracts were published in the Canadian Journal of Ophthalmology. The average impact factor of all publications was 2.73. Of abstracts presented at the 2010 COS Annual Meeting, 45.7% were published within 5 years after the conference. This publication rate is within the upper end of previously reported meeting publication rates for medical societies. Copyright © 2017 Canadian Ophthalmological Society. Published by Elsevier Inc. All rights reserved.

  19. Neuro-Behçet’s disease in childhood: A focus on the neuro-ophthalmological features

    Directory of Open Access Journals (Sweden)

    Mora Paolo

    2013-01-01

    Full Text Available Abstract Neuro-Behçet’s disease (NBD involves the central nervous system; peripheral nervous system involvement is not often reported. NBD is quite common in adult patients and occurs rarely during childhood and adolescence. Young patients may share symptoms and signs of NBD with other neuro-ophthalmological disorders (e.g. idiopathic intracranial hypertension; thus, making the differential diagnosis difficult. Neuroimaging is mandatory and necessary for a correct NBD diagnosis but in children radiological examinations are often difficult to perform without sedation. From 1971 to 2011, 130 patients aged ≤16 years have been reported with NBD, according to retrospective surveys, case series, and case reports. The origin of the reported cases met the well-known geographical distribution of Behçet’s disease (BD; the mean age at presentation of neurological findings was 11.8 years, with male gender prevalence (ratio, 2.9:1. We considered in detail the neuro-ophthalmological features of the 53 cases whose neuroimaging alterations were described with an assigned radiological pattern of the disease (parenchymal: 14 cases, non-parechymal: 35 cases, and mixed: 4 cases. In 19/53 patients (36%, neuro-ophthalmological symptoms anticipated any pathognomonic sign for a BD diagnosis, or only occasional aphtae were recalled by the patients. Family history was positive in 17% of subjects. Headache was reported in 75% of the patients; in those presenting with cerebral vascular involvement, headache was combined to other symptoms of intracranial hypertension. Papilledema was the most frequently reported ophthalmological finding, followed by posterior uveitis. Treatment consisted of systemic steroids in 93% of patients, often combined with other immunosuppressive drugs (especially colchicine and azathioprine. Clinical recovery or improvement was documented in the large majority of patients. Nine subjects had definitive alterations, and one died. Based on our

  20. Early Experience with Technology-Based Eye Care Services (TECS): A Novel Ophthalmologic Telemedicine Initiative.

    Science.gov (United States)

    Maa, April Y; Wojciechowski, Barbara; Hunt, Kelly J; Dismuke, Clara; Shyu, Jason; Janjua, Rabeea; Lu, Xiaoqin; Medert, Charles M; Lynch, Mary G

    2017-04-01

    The aging population is at risk of common eye diseases, and routine eye examinations are recommended to prevent visual impairment. Unfortunately, patients are less likely to seek care as they age, which may be the result of significant travel and time burdens associated with going to an eye clinic in person. A new method of eye-care delivery that mitigates distance barriers and improves access was developed to improve screening for potentially blinding conditions. We present the quality data from the early experience (first 13 months) of Technology-Based Eye Care Services (TECS), a novel ophthalmologic telemedicine program. With TECS, a trained ophthalmology technician is stationed in a primary care clinic away from the main hospital. The ophthalmology technician follows a detailed protocol that collects information about the patient's eyes. The information then is interpreted remotely. Patients with possible abnormal findings are scheduled for a face-to-face examination in the eye clinic. Any patient with no known ocular disease who desires a routine eye screening examination is eligible. Technology-Based Eye Care Services was established in 5 primary care clinics in Georgia surrounding the Atlanta Veterans Affairs hospital. Four program operation metrics (patient satisfaction, eyeglass remakes, disease detection, and visit length) and 2 access-to-care metrics (appointment wait time and no-show rate) were tracked. Care was rendered to 2690 patients over the first 13 months of TECS. The program has been met with high patient satisfaction (4.95 of 5). Eyeglass remake rate was 0.59%. Abnormal findings were noted in 36.8% of patients and there was >90% agreement between the TECS reading and the face-to-face findings of the physician. TECS saved both patient (25% less) and physician time (50% less), and access to care substantially improved with 99% of patients seen within 14 days of contacting the eye clinic, with a TECS no-show rate of 5.2%. The early experience with

  1. Molecular diagnostics of periodontitis

    OpenAIRE

    Izabela Korona-Głowniak; Radosław Siwiec; Marcin Berger; Anna Malm; Jolanta Szymańska

    2017-01-01

    The microorganisms that form dental plaque are the main cause of periodontitis. Their identification and the understanding of the complex relationships and interactions that involve these microorganisms, environmental factors and the host’s health status enable improvement in diagnostics and targeted therapy in patients with periodontitis. To this end, molecular diagnostics techniques (both techniques based on the polymerase chain reaction and those involving nucleic acid analysis via hybridi...

  2. The use of ultrasonographic techniques for the diagnosis of retinopathy of prematurity

    International Nuclear Information System (INIS)

    Modzejewska, M.

    2006-01-01

    Introduction: Ultrasonographic techniques are commonly used for the imaging of various tissue structures and organs, including the eyeball and orbit. The non-invasive ultrasound imaging is safe for the patient and may be repeated after a short time unlike in the case of other radiological techniques. In pediatric ophthalmology, ultrasonography plays a major role as an auxiliary examination for the diagnosis of various intraocular diseases, pathologies of the retina and choroid, and retrobulbar conditions. Ultrasonography is of major importance in diagnosing eye disorders associated with opacity preventing visual inspection of the posterior eye segment. Methods: Among ultrasonographic techniques in pediatric ophthalmology the most frequently used are B-scan, A-scan, and Doppler ultrasonography. Because of the resolution of ultrasonographic methods in comparison to radiological techniques, they play an important role in monitoring the dynamics of pathological processes in retinopathy of prematurity (ROP). Other radiological methods such as CT, MRI or subtractive angiography do not offer a detailed view of retinal attachment or vitreo-retinal proliferation. Conclusion: Ultrasonography as an auxiliary examination at subsequent stages of ROP helps to document the changes and in case of corneal opacity connected with progression of vitreo-retinal abnormalities is the basis for the diagnosis. (author)

  3. International Council of Ophthalmology: Refocusing Ophthalmic Education in the Asia-Pacific Region and Beyond.

    Science.gov (United States)

    Golnik, Karl; Mayorga, Eduardo; Spivey, Bruce; Ritch, Robert; Gauthier, Tina-Marie

    2012-01-01

    The International Council of Ophthalmology (ICO) is a global organization with a regional focus. Working in partnership with supranational and ICO member societies, the ICO is building a "World Alliance for Sight" to improve access to the highest-quality eye care worldwide. Designed to preserve and restore vision on an international scale, the ICO initiative, "Refocusing Ophthalmic Education," enhances ophthalmic education of residents, subspecialists, medical students, and allied eye care personnel by redefining the most effective ways to teach and in creating beneficial educational opportunities. The "Teaching the Teachers" program helps ophthalmic educators incorporate more effective methods of training and continuing professional development to meet societal needs, achieved in part through regional courses for residency program directors; symposia, and keynote talks presented by ICO's World Ophthalmology Educational Colloquium, Conferences for Ophthalmic Educators, and ophthalmic surgical competency rubrics. Recognizing that standardized curricula are essential for consistent ophthalmic education, the ICO has developed a curricular framework whereby goals, expectations, knowledge base, competencies, and technical training are delineated. The ICO is defining worldwide models of team training and compiling best practice, which will include training-program accreditation to ensure improvement in the education of ophthalmologists. International Council of Ophthalmology Web-based teaching courses, a Webinar Network, and a technology blog further support information and communication technologies for teaching and learning. At the ICO's Center for Ophthalmic Educators (educators.icoph.org), trainers will find valuable teaching resources in multiple languages as well as ways to share ideas and collaborate with peers and other ophthalmic educators.

  4. Quality of the ophthalmological service to outpatients of the public and private healthcare systems.

    Science.gov (United States)

    Hercos, Benigno Vicente Santos; Berezovsky, Adriana

    2017-01-01

    To compare perceptions of the quality of ophthalmological services offered to outpatients from the public healthcare system to those from the private healthcare system, and to determine which measures are seen as necessary and a priority for improving the quality of care. This was a prospective observational study on 200 patients, 101 and 99 of whom were from the public and private healthcare systems, respectively. All patients underwent an ophthalmological examination at an ophthalmology hospital in Belo Horizonte, Minas Gerais, Brazil. Personal interviews were conducted using two structured questionnaires adapted from the modified SERVQUAL scale. Overall, patients from the private healthcare system were significantly more dissatisfied than those from the public healthcare system. In both systems, reliability was considered to be the most important determinant of quality, and it presented the highest level of dissatisfaction. Satisfaction with the public healthcare system was significantly greater than that with the private healthcare system in terms of the tangibles, reliability, responsiveness, and assurance determinants of the SERVQUAL scale. Institutions must plan, execute, evaluate, and monitor measures that seek to improve the overall patient satisfaction with the quality of services provided, particularly in the private healthcare system, and special attention must be paid to reliability in both healthcare systems. The identification and monitoring of the quality of healthcare services through the periodic use of the SERVQUAL scale may provide healthcare managers with information so that they can identify, plan, and monitor necessary and priority measures. This could be a key strategy for improving the quality of outpatient health services in the public and private systems.

  5. Ophthalmologic Baseline Characteristics and 2-Year Ophthalmologic Safety Profile of Pramipexole IR Compared with Ropinirole IR in Patients with Early Parkinson’s Disease

    Directory of Open Access Journals (Sweden)

    William Seiple

    2016-01-01

    Full Text Available Background. Parkinson’s disease (PD progressively affects dopaminergic neurotransmission and may affect retinal dopaminergic functions and structures. Objective. This 2-year randomized, open-label, parallel-group, flexible-dose study, NCT00144300, evaluated ophthalmologic safety profiles of immediate-release (IR pramipexole and ropinirole in patients with early idiopathic PD with ≤6 months’ prior dopamine agonist exposure and without preexisting major eye disorders. Methods. Patients received labeled IR regimens of pramipexole (n=121 or ropinirole (n=125 for 2 years. Comprehensive ophthalmologic assessments (COA included corrected acuity, Roth 28-color test, slit-lamp biomicroscopy, intraocular pressure, computerized visual field test, fundus photography, and electroretinography. Results. At baseline, we observed retinal pigmentary epithelium (RPE hypopigmentation not previously reported in PD patients. The estimated relative risk of 2-year COA worsening with pramipexole versus ropinirole was 1.07 (95% CI: 0.71–1.60. Mean changes from baseline in Unified Parkinson’s Disease Rating System parts II+III total scores (pramipexole: 1 year, −4.1±8.9, and 2 years, −0.7±10.1, and ropinirole: 1 year, −3.7±8.2, and 2 years, −1.7±10.5 and Hoehn–Yahr stage distribution showed therapeutic effects on PD symptoms. Safety profiles were consistent with labeling. Conclusions. The risk of retinal deterioration did not differ in early idiopathic PD patients receiving pramipexole versus ropinirole. RPE hypopigmentation at baseline was not previously reported in this population. This trial is registered with NCT00144300.

  6. Diagnostic Accuracy of Imaging Modalities and Injection Techniques for the Diagnosis of Femoroacetabular Impingement/Labral Tear

    DEFF Research Database (Denmark)

    Reiman, Michael P.; Thorborg, Kristian; Goode, Adam P.

    2017-01-01

    Background: Diagnosing femoroacetabular impingement/acetabular labral tear (FAI/ALT) and subsequently making a decision regarding surgery are based primarily on diagnostic imaging and intra-articular hip joint injection techniques of unknown accuracy. Purpose: Summarize and evaluate the diagnostic...... probability of disease was demonstrated. Positive imaging findings increased the probability that a labral tear existed by a minimal to small degree with the use of magnetic resonance imaging/magnetic resonance angiogram (MRI/MRA) and ultrasound (US) and by a moderate degree for CTA. Negative imaging findings...... decreased the probability that a labral tear existed by a minimal degree with the use of MRI and US, a small to moderate degree with MRA, and a moderate degree with CTA. Clinical Relevance: Although findings of the included studies suggested potentially favorable use of these modalities for the diagnosis...

  7. DIABETIC RETINOPATHY SCREENING THROUGH TELE-OPHTHALMOLOGY IN A PRIMARY CARE CENTER IN SOUTHERN BRAZIL.

    NARCIS (Netherlands)

    Rosses, Ana PO; Jornada Ben, A.; Souza, Camila Furtado de; Araújo, Aline Lutz de; Szortika, Adriana; Locatelli, Franciele; Carvalho, Gabriela de; Neumann, Cristina Rolim

    2015-01-01

    Diabetic retinopathy (DR) is a major cause of blindness and its prevalence varies between 15 and 20%. Brazilian people face limited access to ophthalmological services, so strategies in telemedicine to monitor retinal status may help to early diagnose patients developing DR. Objectives: To determine

  8. Plasma diagnostics for tokamaks and stellarators

    International Nuclear Information System (INIS)

    Stott, P.E.; Sanchez, J.

    1994-01-01

    A collection of papers on plasma diagnostics is presented. The papers show the state of the art developments in a series of techniques: magnetic diagnostics, Edge diagnostics, Langmuir probes, Spectroscopy, Microwave and FIR diagnostics as well as Thomson Sattering. Special interest was focused on those diagnostics oriented to fluctuations measurements in the plasma

  9. Development of advanced strain diagnostic techniques for reactor environments.

    Energy Technology Data Exchange (ETDEWEB)

    Fleming, Darryn D.; Holschuh, Thomas Vernon,; Miller, Timothy J.; Hall, Aaron Christopher; Urrea, David Anthony,; Parma, Edward J.,

    2013-02-01

    The following research is operated as a Laboratory Directed Research and Development (LDRD) initiative at Sandia National Laboratories. The long-term goals of the program include sophisticated diagnostics of advanced fuels testing for nuclear reactors for the Department of Energy (DOE) Gen IV program, with the future capability to provide real-time measurement of strain in fuel rod cladding during operation in situ at any research or power reactor in the United States. By quantifying the stress and strain in fuel rods, it is possible to significantly improve fuel rod design, and consequently, to improve the performance and lifetime of the cladding. During the past year of this program, two sets of experiments were performed: small-scale tests to ensure reliability of the gages, and reactor pulse experiments involving the most viable samples in the Annulated Core Research Reactor (ACRR), located onsite at Sandia. Strain measurement techniques that can provide useful data in the extreme environment of a nuclear reactor core are needed to characterize nuclear fuel rods. This report documents the progression of solutions to this issue that were explored for feasibility in FY12 at Sandia National Laboratories, Albuquerque, NM.

  10. Intercomparison of techniques for inspection and diagnostics of heavy water reactor pressure tubes: Flaw detection and characterization [Phase 1

    International Nuclear Information System (INIS)

    2006-05-01

    Nuclear power plants with heavy water reactors (HWRs) comprise nine percent of today's operating nuclear units, and more are under construction. Efficient and accurate inspection and diagnostic techniques for various reactor components and systems are an important factor in assuring reliable and safe plant operation. To foster international collaboration in the efficient and safe use of nuclear power, the IAEA conducted a Coordinated Research Programme (CRP) on Inter-comparison of Techniques for HWR Pressure Tube Inspection and Diagnostics. This CRP was carried out within the frame of the IAEA Department of Nuclear Energy's Technical Working Group on Advanced Technologies for HWRs (the TWG-HWR). The TWG-HWR is a group of experts nominated by their governments and designated by the IAEA to provide advice and to support implementation of the IAEA's project on advanced technologies for HWRs. The objective of the CRP was to inter-compare non-destructive inspection and diagnostic techniques, in use and being developed, for structural integrity assessment of HWR pressure tubes. During the first phase of this CRP, participants have investigated the capability of different techniques to detect and characterize flaws. During the second phase of this CRP, participants collaborated to detect and characterize hydride blisters and to determine the hydrogen concentration in Zirconium alloys. The intent was to identify the most effective pressure tube inspection and diagnostic methods, and to identify further development needs. The organizations that have participated in this CRP are: - The Comision Nacional de Energia Atomica (CNEA), Argentina; - Atomic Energy of Canada Ltd. (AECL); Chalk River Laboratories (CRL), Canada; - The Research Institute of Nuclear Power Operations (RINPO), China National Nuclear Corporation (CNNC), China; - Bhabha Atomic Research Centre (BARC), India; - The Korea Electric Power Research Institute (KEPRI), Republic of Korea; - The Korea Atomic Energy

  11. Radiation levels in nuclear diagnostic examinations

    International Nuclear Information System (INIS)

    Vermeulen, A.M.T.I.

    1987-01-01

    To estimate the risks for a pregnant radiological worker, radiation level measurements are executed for common nuclear diagnostic techniques. These measurements are combined with the time which the radiologic worker is present during the performance of the diagnostic techniques. It is concluded that a radiologic worker is receiving less than 5 mSv during pregnancy. This is the case with in vivo determination in a department of nuclear medicine with common diagnostic techniques. Reduction of radiation doses during pregnancy is possible by reduction of heart function examinations, skeletal examinations and brain scans. 1 figure; 13 tabs

  12. Factors influencing the choice of ophthalmology as a career among medical students of king saud bin abdulaziz university Riyadh, Saudi Arabia

    Directory of Open Access Journals (Sweden)

    Sarah Abdullah AlSalman

    2017-01-01

    Full Text Available Context: Choosing a future speciality for medical students can be frightening as well as confusing. Identifying factors that influence medical students' future career choice is critical and can play an important role in shaping the future workforce. Aims: The study aims to determine factors associated with medical students' preference of Ophthalmology as a future career choice at King Saud bin Abdulaziz University for Health Sciences (KSAU-HS. Settings and Design: A cross-sectional study was carried out among Saudi students of both genders who were enrolled in KSAU-HS (clinical phase during the study. Subjects and Methods: A validated questionnaire was sent through E-mail to 302 eligible students, of which 275 participated, with a response rate of (91%. Statistical Analysis Used: Descriptive analysis was carried out for all categorical variables. In addition, data were compared using Chi-square test; all tests were two-sided and P < 0.05 was considered statistically significant. Results: A total of 28 students (10.2% considered Ophthalmology as their first choice, while it was the second choice for four students (1.5%. Among all the participants, factors that attracted medical students to consider Ophthalmology as a career choice included the high income (54%, private sector opportunities (40%, part-time opportunities (40% and leisure (34%. Whereas, the difficulty of getting into the Ophthalmology Residency Programme (53% was the most important factor that pushed students away from choosing Ophthalmology. Conclusions: Multiple factors influenced the KSAU-HS medical students' choice of when choosing a future speciality. Knowing these factors can help in directing work-force to choose specialities that are currently limited in Saudi Arabia.

  13. Basic and clinical application progression of invigorating blood and dissolving stasis Chinese medicine in ophthalmology

    Directory of Open Access Journals (Sweden)

    Ying Wang

    2017-06-01

    Full Text Available Invigorating blood and dissolving stasis method is a kind of unique therapy of Traditional Chinese Medicine(TCMtreatment, which efficacy has become increasingly prominent in the treatment of ophthalmology. With the further studies of blood stasis and invigorating blood and dissolving stasis therapy, it is widely used in clinical ophthalmology, and get good effects beyond thought, especially when western medicine has no curative effects. It improved the cure rate of fundus oculi disease from the eyelids, conjunctiva, lacrimal sac, vitreous body to the choroid and retina, optic nerve and macula lutea, from surface to fundus, or pathological changes related to inflammation, degeneration, necrosis, atrophy, hyperplasia of fibrous tissue hyperplasia. This paper is aim to explain the definition of invigorating blood and dissolving stasis and make a review of basic research and clinical application about it in several diseases.

  14. Diagnostic Development on NSTX

    International Nuclear Information System (INIS)

    A.L. Roquemore; D. Johnson; R. Kaita; et al

    1999-01-01

    Diagnostics are described which are currently installed or under active development for the newly commissioned NSTX device. The low aspect ratio (R/a less than or equal to 1.3) and low toroidal field (0.1-0.3T) used in this device dictate adaptations in many standard diagnostic techniques. Technical summaries of each diagnostic are given, and adaptations, where significant, are highlighted

  15. Plasma diagnostics for tokamaks and stellarators

    Energy Technology Data Exchange (ETDEWEB)

    Stott, P E; Sanchez, J

    1994-07-01

    A collection of papers on plasma diagnostics is presented. The papers show the state of the art developments in a series of techniques: Magnetic diagnostics, Edge diagnostics, Langmuir probes, Spectroscopy, Microwave and FIR diagnostics as well as Thomson Scattering. Special interest was focused on those diagnostics oriented to fluctuations measurements in the plasma. (Author) 451 refs.

  16. Monte Carlo techniques in diagnostic and therapeutic nuclear medicine

    International Nuclear Information System (INIS)

    Zaidi, H.

    2002-01-01

    Monte Carlo techniques have become one of the most popular tools in different areas of medical radiation physics following the development and subsequent implementation of powerful computing systems for clinical use. In particular, they have been extensively applied to simulate processes involving random behaviour and to quantify physical parameters that are difficult or even impossible to calculate analytically or to determine by experimental measurements. The use of the Monte Carlo method to simulate radiation transport turned out to be the most accurate means of predicting absorbed dose distributions and other quantities of interest in the radiation treatment of cancer patients using either external or radionuclide radiotherapy. The same trend has occurred for the estimation of the absorbed dose in diagnostic procedures using radionuclides. There is broad consensus in accepting that the earliest Monte Carlo calculations in medical radiation physics were made in the area of nuclear medicine, where the technique was used for dosimetry modelling and computations. Formalism and data based on Monte Carlo calculations, developed by the Medical Internal Radiation Dose (MIRD) committee of the Society of Nuclear Medicine, were published in a series of supplements to the Journal of Nuclear Medicine, the first one being released in 1968. Some of these pamphlets made extensive use of Monte Carlo calculations to derive specific absorbed fractions for electron and photon sources uniformly distributed in organs of mathematical phantoms. Interest in Monte Carlo-based dose calculations with β-emitters has been revived with the application of radiolabelled monoclonal antibodies to radioimmunotherapy. As a consequence of this generalized use, many questions are being raised primarily about the need and potential of Monte Carlo techniques, but also about how accurate it really is, what would it take to apply it clinically and make it available widely to the medical physics

  17. Photon acceleration versus frequency-domain interferometry for laser wakefield diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Dias, J M; Oliveira e Silva, L; Mendonca, J T [GoLP/Centro de Fisica de Plasmas, Inst. Superior Tecnico, Lisbon (Portugal)

    1998-03-01

    A detailed comparison between the photon acceleration diagnostic technique and the frequency-domain interferometric technique for laser wakefield diagnostics, by using ray-tracing equations is presented here. The dispersion effects on the probe beam and the implications of an arbitrary phase velocity of the plasma wave are discussed for both diagnostic techniques. In the presence of large amplitude plasma wave and long interaction distances significant frequency shifts can be observed. The importance of this effect on the determination of the phase and frequency shifts measurements given by each of the two diagnostic techniques, is also analyzed. The accuracy of both diagnostic techniques is discussed and some of their technical problems are reviewed. (author)

  18. Rate of Unverifiable Publications Among Ophthalmology Residency Applicants Invited to Interview.

    Science.gov (United States)

    Tamez, Heather M; Tauscher, Robert; Brown, Eric N; Wayman, Laura; Mawn, Louise A

    2018-04-19

    Unverifiable publications in applications for ophthalmology residencies could be a serious concern if they represent publication dishonesty. To determine the rate of unverifiable publications among applicants offered an interview. Retrospective review of 322 ophthalmology residency applications for entering classes 2012 to 2017 at Vanderbilt University School of Medicine, Nashville, Tennessee. Full-length publications reported in the applications were searched in PubMed, Google, Google Scholar, and directly on the journal's website. Applications were deemed unverifiable if there was no record of the publication by any of these means or if substantial discrepancies existed, such as incorrect authorship, incorrect journal, or a meaningful discrepancy in title or length (full-length article vs abstract). Inability to locate publication with search, incorrect author position, applicant not listed as an author, article being an abstract and not a published paper, substantial title discrepancy suggesting an alternative project, and incorrect journal. Of the 322 applicants offered interviews during the 6-year study period, 22 (6.8%) had 24 unverifiable publications. Two hundred thirty-nine of these applicants (74.2%) reported at least 1 qualifying publication; of this group, 22 (9.2%) had an unverifiable publication. The applications with unverifiable publications were evenly distributed across the years of the study (range, 2-6 per cycle; Pearson χ25 = 3.65; P = .60). Two applicants had 2 unverifiable publications each. Two of the 22 applicants (9.1%) with unverifiable publications were graduates of medical schools outside the United States. Among the unverifiable publications, the most common reason was inability to locate the publication (13 [54%]). Additional issues included abstract rather than full-length publication (5 [20.8%]), incorrect author position (4 [16.7%]), applicant not listed as an author on the publication (1 [4.2%]), and substantial title

  19. Ophthalmological screening of a paediatric cochlear implant population: a retrospective analysis and 12-year follow-up.

    LENUS (Irish Health Repository)

    Falzon, K

    2010-06-01

    To determine the nature and prevalence of ophthalmological findings for a cohort of children in a paediatric cochlear implant program and to assist the clinician in devising an investigative plan for this population.

  20. Stem Cell Ophthalmology Treatment Study (SCOTS): bone marrow-derived stem cells in the treatment of Leber's hereditary optic neuropathy

    Science.gov (United States)

    Weiss, Jeffrey N.; Levy, Steven; Benes, Susan C.

    2016-01-01

    The Stem Cell Ophthalmology Treatment Study (SCOTS) is currently the largest-scale stem cell ophthalmology trial registered at ClinicalTrials.gov (identifier: NCT01920867). SCOTS utilizes autologous bone marrow-derived stem cells (BMSCs) to treat optic nerve and retinal diseases. Treatment approaches include a combination of retrobulbar, subtenon, intravitreal, intra-optic nerve, subretinal, and intravenous injection of autologous BMSCs according to the nature of the disease, the degree of visual loss, and any risk factors related to the treatments. Patients with Leber's hereditary optic neuropathy had visual acuity gains on the Early Treatment Diabetic Retinopathy Study (ETDRS) of up to 35 letters and Snellen acuity improvements from hand motion to 20/200 and from counting fingers to 20/100. Visual field improvements were noted. Macular and optic nerve head nerve fiber layer typically thickened. No serious complications were seen. The increases in visual acuity obtained in our study were encouraging and suggest that the use of autologous BMSCs as provided in SCOTS for ophthalmologic mitochondrial diseases including Leber's hereditary optic neuropathy may be a viable treatment option. PMID:27904503

  1. Ophthalmologic changes related to radiation exposure and age in the adult health study sample, Hiroshima and Nagasaki

    International Nuclear Information System (INIS)

    Choshi, Kanji; Mishima, Hiromu; Takaku, Isao; Takase, Tomoko; Neriishi, Shotaro.

    1983-11-01

    A two-year ophthalmologic study of age- and radiation-related ophthalmologic lesions among the Adult Health Study (AHS) population of Hiroshima and Nagasaki was conducted at RERF in 1978-80. The study population in both cities was composed of all persons exposed to 100+ rad in the AHS, their controls, and all other persons in the AHS sample with a previous record of axial opacities or posterior subcapsular changes, and the in utero clinical sample. The ophthalmologic examination was conducted on 1,582 persons in Hiroshima and 719 persons in Nagasaki belonging to the AHS sample, and 67 persons in Hiroshima and 17 persons in Nagasaki belonging to the in utero clinical sample. Participation in the study was 42% of the eligible AHS sample in Hiroshima and 21% in Nagasaki, and 24% of the eligible in utero sample in Hiroshima and 26% in Nagasaki. Increased lenticular opacities, other lens changes, and loss of visual acuity and accommodation occurred with increasing age in both exposed and control subjects as manifestations of the normal aging process. A highly significant excess risk for all ages in the 300+ rad group in comparison to those in the control group was observed for both axial opacities and posterior subcapsular changes in Hiroshima, but not in Nagasaki. (J.P.N.)

  2. Uncertainty Management for Diagnostics and Prognostics of Batteries using Bayesian Techniques

    Science.gov (United States)

    Saha, Bhaskar; Goebel, kai

    2007-01-01

    Uncertainty management has always been the key hurdle faced by diagnostics and prognostics algorithms. A Bayesian treatment of this problem provides an elegant and theoretically sound approach to the modern Condition- Based Maintenance (CBM)/Prognostic Health Management (PHM) paradigm. The application of the Bayesian techniques to regression and classification in the form of Relevance Vector Machine (RVM), and to state estimation as in Particle Filters (PF), provides a powerful tool to integrate the diagnosis and prognosis of battery health. The RVM, which is a Bayesian treatment of the Support Vector Machine (SVM), is used for model identification, while the PF framework uses the learnt model, statistical estimates of noise and anticipated operational conditions to provide estimates of remaining useful life (RUL) in the form of a probability density function (PDF). This type of prognostics generates a significant value addition to the management of any operation involving electrical systems.

  3. Probabilistic techniques using Monte Carlo sampling for multi- component system diagnostics

    International Nuclear Information System (INIS)

    Aumeier, S.E.; Lee, J.C.; Akcasu, A.Z.

    1995-01-01

    We outline the structure of a new approach at multi-component system fault diagnostics which utilizes detailed system simulation models, uncertain system observation data, statistical knowledge of system parameters, expert opinion, and component reliability data in an effort to identify incipient component performance degradations of arbitrary number and magnitude. The technique involves the use of multiple adaptive Kalman filters for fault estimation, the results of which are screened using standard hypothesis testing procedures to define a set of component events that could have transpired. Latin Hypercube sample each of these feasible component events in terms of uncertain component reliability data and filter estimates. The capabilities of the procedure are demonstrated through the analysis of a simulated small magnitude binary component fault in a boiling water reactor balance of plant. The results show that the procedure has the potential to be a very effective tool for incipient component fault diagnosis

  4. An Analysis of Peer-Reviewed Scores and Impact Factors with Different Citation Time Windows: A Case Study of 28 Ophthalmologic Journals.

    Science.gov (United States)

    Liu, Xue-Li; Gai, Shuang-Shuang; Zhang, Shi-Le; Wang, Pu

    2015-01-01

    An important attribute of the traditional impact factor was the controversial 2-year citation window. So far, several scholars have proposed using different citation time windows for evaluating journals. However, there is no confirmation whether a longer citation time window would be better. How did the journal evaluation effects of 3IF, 4IF, and 6IF comparing with 2IF and 5IF? In order to understand these questions, we made a comparative study of impact factors with different citation time windows with the peer-reviewed scores of ophthalmologic journals indexed by Science Citation Index Expanded (SCIE) database. The peer-reviewed scores of 28 ophthalmologic journals were obtained through a self-designed survey questionnaire. Impact factors with different citation time windows (including 2IF, 3IF, 4IF, 5IF, and 6IF) of 28 ophthalmologic journals were computed and compared in accordance with each impact factor's definition and formula, using the citation analysis function of the Web of Science (WoS) database. An analysis of the correlation between impact factors with different citation time windows and peer-reviewed scores was carried out. Although impact factor values with different citation time windows were different, there was a high level of correlation between them when it came to evaluating journals. In the current study, for ophthalmologic journals' impact factors with different time windows in 2013, 3IF and 4IF seemed the ideal ranges for comparison, when assessed in relation to peer-reviewed scores. In addition, the 3-year and 4-year windows were quite consistent with the cited peak age of documents published by ophthalmologic journals. Our study is based on ophthalmology journals and we only analyze the impact factors with different citation time window in 2013, so it has yet to be ascertained whether other disciplines (especially those with a later cited peak) or other years would follow the same or similar patterns. We designed the survey questionnaire

  5. Diagnostics of glass fiber reinforced polymers and comparative analysis of their fabrication techniques with the use of acoustic emission

    Science.gov (United States)

    Bashkov, O. V.; Bryansky, A. A.; Panin, S. V.; Zaikov, V. I.

    2016-11-01

    Strength properties of the glass fiber reinforced polymers (GFRP) fabricated by vacuum and vacuum autoclave molding techniques were analyzed. Measurements of porosity of the GFRP parts manufactured by various molding techniques were conducted with the help of optical microscopy. On the basis of experimental data obtained by means of acoustic emission hardware/software setup, the technique for running diagnostics and forecasting the bearing capacity of polymeric composite materials based on the result of three-point bending tests has been developed. The operation principle of the technique is underlined by the evaluation of the power function index change which takes place on the dependence of the total acoustic emission counts versus the loading stress.

  6. Ahmed glaucoma valve implant: surgical technique and complications

    Directory of Open Access Journals (Sweden)

    Riva I

    2017-02-01

    Full Text Available Ivano Riva,1 Gloria Roberti,1 Francesco Oddone,1 Anastasios GP Konstas,2 Luciano Quaranta3 1IRCCS “Fondazione GB Bietti per l’Oftalmologia”, Rome, Italy; 21st University Department of Ophthalmology, Glaucoma Unit, AHEPA Hospital, Thessaloniki, Greece; 3Department of Medical and Surgical Specialties, Section of Ophthalmology, University of Brescia, Brescia, Italy Abstract: Implantation of Ahmed glaucoma valve is an effective surgical technique to reduce intraocular pressure in patients affected with glaucoma. While in the past, the use of this device was reserved to glaucoma refractory to multiple filtration surgical procedures, up-to-date mounting experience has encouraged its use also as a primary surgery for selected cases. Implantation of Ahmed glaucoma valve can be challenging for the surgeon, especially in patients who already underwent previous multiple surgeries. Several tips have to be acquired by the surgeon, and a long learning curve is always needed. Although the valve mechanism embedded in the Ahmed glaucoma valve decreases the risk of postoperative hypotony-related complications, it does not avoid the need of a careful follow-up. Complications related to this type of surgery include early and late postoperative hypotony, excessive capsule fibrosis around the plate, erosion of the tube or plate edge, and very rarely infection. The aim of this review is to describe surgical technique for Ahmed glaucoma valve implantation and to report related complications. Keywords: glaucoma, surgical technique, glaucoma drainage devices, Ahmed glaucoma valve, complications

  7. Integrated Artificial Intelligence Approaches for Disease Diagnostics.

    Science.gov (United States)

    Vashistha, Rajat; Chhabra, Deepak; Shukla, Pratyoosh

    2018-06-01

    Mechanocomputational techniques in conjunction with artificial intelligence (AI) are revolutionizing the interpretations of the crucial information from the medical data and converting it into optimized and organized information for diagnostics. It is possible due to valuable perfection in artificial intelligence, computer aided diagnostics, virtual assistant, robotic surgery, augmented reality and genome editing (based on AI) technologies. Such techniques are serving as the products for diagnosing emerging microbial or non microbial diseases. This article represents a combinatory approach of using such approaches and providing therapeutic solutions towards utilizing these techniques in disease diagnostics.

  8. Diagnostic technique for measuring fusion reaction rate for inertial confinement fusion experiments at Shen Guang-III prototype laser facility

    International Nuclear Information System (INIS)

    Wang Feng; Peng Xiao-Shi; Liu Shen-Ye; Xu Tao; Kang Dong-Guo

    2013-01-01

    A study is conducted using a two-dimensional simulation program (Lared-s) with the goal of developing a technique to evaluate the effect of Rayleigh-Taylor growth in a neutron fusion reaction region. Two peaks of fusion reaction rate are simulated by using a two-dimensional simulation program (Lared-s) and confirmed by the experimental results. A neutron temporal diagnostic (NTD) system is developed with a high temporal resolution of ∼ 30 ps at the Shen Guang-III (SG-III) prototype laser facility in China, to measure the fusion reaction rate history. With the shape of neutron reaction rate curve and the spherical harmonic function in this paper, the degree of Rayleigh-Taylor growth and the main source of the neutron yield in our experiment can be estimated qualitatively. This technique, including the diagnostic system and the simulation program, may provide important information for obtaining a higher neutron yield in implosion experiments of inertial confinement fusion

  9. Upgrades of Diagnostic Techniques and Technologies for JET next D-T Campaigns

    Energy Technology Data Exchange (ETDEWEB)

    Murari, Andrea [Consorzio RFX - CNR, ENEA, INFN, Universita di Padova, Acciaierie Venete SpA,Corso Stati Uniti 4, 35127 Padova (Italy)

    2015-07-01

    . With regard to the fusion products, JET now can deploy a consistent set of techniques to measure the neutron yield and neutron spectra and to diagnose the fast particles. A full calibration of the neutron diagnostics with a 14 MeV source is being considered, after the recent very successful calibration for the 2.45 MeV neutrons. Vertical and horizontal lines of sight are foreseen for neutron and gamma spectrometry, in order to better determine the thermal neutron yield and to separate the trapped and passing components of the alphas. Various gamma ray spectrometers are being developed to cover all the various operational scenarios, from trace tritium to 50-50 D-T operation. The redistribution of the alphas will be measured with the gamma ray cameras, recently upgraded with full digital electronics; new detectors are being considered to bring the time resolution of the system in the ten of ms range. The lost alphas will also be diagnosed with improved spatial and temporal resolution, using Faraday cups and a scintillator probe. From a technological perspective, the D-T campaign will provide a unique opportunity to test ITER relevant technologies. From radiation hard detectors, for example Hall probes, to neutron absorbers and to shielding concepts, the potential of various solutions in a realistic 14 MeV radiation field will be assessed. The effects of neutrons and gamma on ancillary technologies and systems, such as fibre optics and electronics circuits, are also expected to be sufficiently high to derive useful information about the competitive advantage of various alternatives.

  10. Listas de comprobación de las habilidades prácticas de la asignatura Oftalmología Checking lists of the practical abilities of the Ophthalmology subject

    Directory of Open Access Journals (Sweden)

    Georgina Saint-Blancard Morgado

    2001-06-01

    Full Text Available En la asignatura Oftalmología los procederes diagnósticos se basan en exámenes instrumentados que requieren un entrenamiento especial y sistemático para la adquisión de las habilidades. La evaluación sistemática y el examen práctico, basados en la observación, constituyen las vías fundamentales para constatar su apropiación. Con el fin de hacer más certeros los juicios y unificar criterios, se diseñaron sobre la base de la teoría de la actividad, listas de comprobación para 3 de las habilidades que se incluyen en el programa de la asignatura Oftalmología en 5to. año de Medicina. Se incluyen además los criterios de calificación.In the Ophthalmology subject the diagnostic procedures are based on tests designed in such a way that require a special and systematic training for the acquisition of abilities. The systematic evaluation and the practical test, which are based on obervation, are the fundamental ways to verify their suitability. In order to make judgments more accurate and to unify criteria, checking lists for 3 of the abilities included in the program of Ophthalmology subject in the 5th year of Medicine were made on the basis of the theory of activity. The marking criteria were also taken into consideration

  11. IERIAS: inference engine for reactor accident diagnostic system using knowledge engineering technique

    International Nuclear Information System (INIS)

    Yokobayashi, Masao; Yoshida, Kazuo; Kohsaka, Atsuo; Yamamoto, Minoru.

    1984-11-01

    This report describes an inference engine IERIAS which has been devoloped for a diagnostic system to identify the cause and type of an abnormal transient of a reactor plant. This system using knowledge engineering technique consists of a knowledge base and an inference engine. The inference engine IERIAS is designed so as to treat time-varying data of a plant. The major features of IERIAS are ; (1) histroy of transients can be treated, (2) knowledge base can be divided into some knowledge units, (3) program language UTILISP is used which is suitable for symbolic data manipulation. Inference was made using IERIAS with a knowledge base which was created from simulated results of various transients by a PWR plant simulator. The results showed a good applicability of IERIAS for reactor diagnosis. (author)

  12. Nanotechnology and glaucoma: a review of the potential implications of glaucoma nanomedicine.

    Science.gov (United States)

    Kim, Nathaniel J; Harris, Alon; Gerber, Austin; Tobe, Leslie Abrams; Amireskandari, Annahita; Huck, Andrew; Siesky, Brent

    2014-04-01

    The purpose of this review is to discuss the evolution of nanotechnology and its potential diagnostic and therapeutic applications in the field of ophthalmology, particularly as it pertains to glaucoma. We reviewed literature using MEDLINE and PubMed databases with the following search terms: glaucoma, nanotechnology, nanomedicine, nanoparticles, ophthalmology and liposomes. We also reviewed pertinent references from articles found in this search. A brief history of nanotechnology and nanomedicine will be covered, followed by a discussion of the advantages and concerns of using this technology in the field of glaucoma. We will look at various studies concerning the development of nanomedicine, its potential applications in ocular drug delivery, diagnostic and imaging modalities and, surgical techniques. In particular, the challenges of assuring safety and efficacy of nanomedicine will be examined. We conclude that nanotechnology offers a novel approach to expanding diagnostic, imaging and surgical modalities in glaucoma and may contribute to the knowledge of disease pathogenesis at a molecular level. However, more research is needed to better elucidate the mechanism of cellular entry, the potential for nanoparticle cytotoxicity and the assurance of clinical efficacy.

  13. Summary from working group on noninterceptive diagnostics

    International Nuclear Information System (INIS)

    Chamberlin, D.D.

    1985-01-01

    The working group for noninterceptive diagnostics spent much of its time comparing diagnostic techniques from different fields and their possible application to high-power injectors. The group included backgrounds from electron beam diagnostics, fusion power diagnostics, cw ion source and transport design, and ion beam of diagnostics. The probability of success for adapting techniques from these different areas is quite difficult to judge, short of a detailed examination of each application. Unexpected flaws or unforeseen noise sources can eliminate an idea that would otherwise appear promising. The report presents several ideas that were discussed, with an indication of those ideas most likely to succeed if implemented

  14. Effectiveness of mobile-phone short message service (SMS reminders for ophthalmology outpatient appointments: Observational study

    Directory of Open Access Journals (Sweden)

    Car Josip

    2008-05-01

    Full Text Available Abstract Background Non-attendance for hospital outpatient appointments is a significant problem in many countries. It causes suboptimal use of clinical and administrative staff and financial losses, as well as longer waiting times. The use of Short Message Service (SMS appointment reminders potentially offers a cost-effective and time-efficient strategy to decrease non-attendance and so improve the efficiency of outpatient healthcare delivery. Methods An SMS text message was sent to patients with scheduled appointments between April and September 2006 in a hospital ophthalmology department in London, reminding them of their appointments. This group acted as the intervention group. Controls were patients with scheduled ophthalmology appointments who did not receive an SMS or any alternative reminder. Results During the period of the study, 11.2% (50/447 of patients who received an SMS appointment reminder were non-attenders, compared to 18.1% (1720/9512 who did not receive an SMS reminder. Non-attendance rates were 38% lower in patients who received an SMS reminder than in patients who did not receive a reminder (RR of non-attendance = 0.62; 95% CI = 0.48 – 0.80. Conclusion The use of SMS reminders for ophthalmology outpatient appointments was associated with a reduction of 38% in the likelihood of patients not attending their appointments, compared to no appointment reminder. The use of SMS reminders may also be more cost-effective than traditional appointment reminders and require less labour. These findings should be confirmed with a more rigorous study design before a wider roll-out.

  15. A study on the fault diagnostic techniques for reactor internal structures using neutron noise analysis

    International Nuclear Information System (INIS)

    Kim, Tae Ryong; Jeong, Seong Ho; Park, Jin Ho; Park, Jin Suk

    1994-08-01

    The unfavorable phenomena, such as flow induced vibration and aging process in reactor internals, cause degradation of structural integrity and may result in loosing some mechanical binding components which might impact other equipments and components or cause flow blockage. Since these malfunctions and potential failures change reactor noise signal, it is necessary to analyze reactor noise signal for early fault diagnosis in the point of few of safety and plant economics. The objectives of this study are to establish fault diagnostic and TS(thermal shield), and to develop a data acquisition and signal processing software system. In the first year of this study, an analysis technique for the reactor internal vibration using the reactor noise was proposed. With the technique proposed and the reactor noise signals (ex-core neutron and acceleration), the dynamic characteristics of Ulchin-1 reactor internals were obtained, and compared with those of Tricastin-1 which is the prototype of Ulchin-1. In the second year, a PC-based expert system for reactor internals fault diagnosis is developed, which included data acquisition, signal processing, feature extraction function, and represented diagnostic knowledge by the IF-THEN rule. To know the effect of the faults, the reactor internals of Ulchin-1 is modeled using FEM and simulated with an artificial defect given in the hold-down spring. Trend in the dynamic characteristics of reactor internals is also observed during one fuel cycle to know the effect of boron concentration. 100 figs, 7 tabs, 18 refs. (Author)

  16. Danish Ophthalmology - from start to 1865.

    Science.gov (United States)

    Norn, Mogens

    2016-03-01

    This short paper mentioned the medical treatment using the 'holy' springs, the first 'eye doctor' in Denmark, the first picture of spectacles which was found in Viborg Cathedral of the high priest before he performs circumcisio praeputii on Jesus Christ, further cataract reclination in Denmark from around year zero and cataract extraction in 1667 in Denmark on a goose by Francisco Borri and on humans by the Danish Georg Heuermann in 1755. Epidemic military eye diseases in 1807, 1856 and 1865 are also described in this study. From 1856, a new ophthalmological period started in Denmark with the first eye hospital (lazaret only for eye diseases), and in 1864, patients with eye diseases were transported from the few beds in the surgical departments in the municipal hospital to the first civil eye department in Denmark, the eye hospital Sct. Annae in Copenhagen. The new scientific period started with Jacob Christian Bentz (ophthalmia granulosa, joint editor of the Danish Medical Journal) and Heinrich Lehmann. © 2016 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  17. Mining for diagnostic information in body surface potential maps: A comparison of feature selection techniques

    Directory of Open Access Journals (Sweden)

    McCullagh Paul J

    2005-09-01

    Full Text Available Abstract Background In body surface potential mapping, increased spatial sampling is used to allow more accurate detection of a cardiac abnormality. Although diagnostically superior to more conventional electrocardiographic techniques, the perceived complexity of the Body Surface Potential Map (BSPM acquisition process has prohibited its acceptance in clinical practice. For this reason there is an interest in striking a compromise between the minimum number of electrocardiographic recording sites required to sample the maximum electrocardiographic information. Methods In the current study, several techniques widely used in the domains of data mining and knowledge discovery have been employed to mine for diagnostic information in 192 lead BSPMs. In particular, the Single Variable Classifier (SVC based filter and Sequential Forward Selection (SFS based wrapper approaches to feature selection have been implemented and evaluated. Using a set of recordings from 116 subjects, the diagnostic ability of subsets of 3, 6, 9, 12, 24 and 32 electrocardiographic recording sites have been evaluated based on their ability to correctly asses the presence or absence of Myocardial Infarction (MI. Results It was observed that the wrapper approach, using sequential forward selection and a 5 nearest neighbour classifier, was capable of choosing a set of 24 recording sites that could correctly classify 82.8% of BSPMs. Although the filter method performed slightly less favourably, the performance was comparable with a classification accuracy of 79.3%. In addition, experiments were conducted to show how (a features chosen using the wrapper approach were specific to the classifier used in the selection model, and (b lead subsets chosen were not necessarily unique. Conclusion It was concluded that both the filter and wrapper approaches adopted were suitable for guiding the choice of recording sites useful for determining the presence of MI. It should be noted however

  18. Diagnostic accuracy of magnetic resonance imaging techniques for treatment response evaluation in patients with head and neck tumors, a systematic review and meta-analysis

    NARCIS (Netherlands)

    van der Hoorn, Anouk; van Laar, Peter Jan; Holtman, Gea A.; Westerlaan, Henriette E.

    2017-01-01

    Background Novel advanced MRI techniques are investigated in patients treated for head and neck tumors as conventional anatomical MRI is unreliable to differentiate tumor from treatment related imaging changes. Purpose As the diagnostic accuracy of MRI techniques to detect tumor residual or

  19. Diagnostic imaging techniques in Rubinstein-Taybi syndrome

    International Nuclear Information System (INIS)

    Albanese, A.; Carcione, A.; Benenati, A.; Albano, S.; Rubino, F.P.; Reina, C.; Verde, V.; Giuffre, L.; Corsello, G.; Cammarata, M.; Piccione, M.

    1991-01-01

    Both etiology and pathogenesis of Rubinstein-Taybi syndrome (RTS) are still questionable, even though a genetic factor seems to be certain. A typical face, psychomotor delay, and thumb and halluces abnormalities (big, prevalently short, and often 'spoon-like' toes) are the main characteristic patterns of RTS. Eight subjects (4 male and 3 female children aged 26 days-7 years, and a 31-year old woman, mother of 1 of the affected children) with different signs of RTS were studied over the last 3 years. The results are here reported, with a special emphasis on malformations detected with conventional radiography (Rx), Computerized Tomography (CT), and ultrasound (US). Evaluated parameters were thumbs and halluces (Rx), bone age and skeleton (Rx), cranium (Rx) and encephalon (US, CT), cryptochidism (US, CT), and urogical (Rx, US) and carciovascolar (US) system. Atypical face and psycomotor delay were found in all cases, while thumb and halluces abnormalities were observed only in 6 cases. Among several clinical signs of RTS, we found: severe (<3rd centile) bone maturation delay in 4 cases; skull volume reduction (<50th centile) in 3 subjects and microcrania in 4; skeletal abnormalities in 7 cases (5 of them positive for bilateral coxofemoral abnormalities); urinary tract (4 cases) and cardiovascular (3 cases) malformation; and cryptorcidism in 3 of 4 males. A case was diagnosed during neonatal period (within the first month of life) it was a rare case associated with a variant form of Dandy-Walker anomaly; semiologic similarities were observed between mother and daughter patients. X-rays, US and CT rarely play an important role in the diagnosis of RTS, considering the several clinical signs, mainly tha face, affecting the patients. However, diagnostic imaging techniques help diagnose hidden malformations and confirm and integrate clinical signs

  20. Pigment dispersion syndrome associated with intraocular lens implantation: a new surgical technique

    Directory of Open Access Journals (Sweden)

    M Isabel Canut Jordana

    2010-11-01

    Full Text Available M Isabel Canut Jordana1, Daniel Pérez Formigó1, Rodrigo Abreu González2, Jeroni Nadal Reus11Barraquer Ophthalmology Centre, Barcelona, Spain; 2University Hospital of La Candelaria, Tenerife, SpainAims: We report the case of a myopic patient who, after intraocular lens transplant in the posterior chamber, suffered elevated intraocular pressure due to pigment dispersion, with recurrent episodes of blurred vision. The patient was treated with a new surgical technique that can avoid potential iridolenticular contact.Methods: Complete ophthalmologic examination and optical coherence tomography (OCT of the anterior segment were performed.Results: Contact between the pigmentary epithelium and the iris with an intraocular lens was revealed by utrasound biomicroscopy and OCT. In this case, Nd:YAG laser iridotomy and laser iridoplasty were not effective for iridolenticular separation and control of the pigment dispersion. We propose a new technique: stitches on the surface of the iris to obtain good iridolenticular separation and good intraocular pressure control.Conclusion: Stitches on the iris surface should be considered as optional therapy in pigmentary glaucoma secondary to intraocular lens implantation. This surgical technique can avoid potential iridolenticular contacts more definitively.Keywords: pigmentary glaucoma, intraocular lens, optical coherence tomography, laser

  1. Ophthalmologic abnormalities in Mowat-Wilson syndrome and a mutation in ZEB2.

    Science.gov (United States)

    Ariss, Michelle; Natan, Kristina; Friedman, Neil; Traboulsi, Elias I

    2012-09-01

    Mowat-Wilson syndrome is a genetic disorder characterized by a distinct facial appearance, moderate-to-severe mental retardation, microcephaly, agenesis of the corpus callosum, Hirschsprung disease, congenital heart disease, and genital anomalies. Ophthalmological abnormalities have been rarely described in patients with this condition which is caused by mutations in the ZEB2 gene. We report a 9-year-old female with this syndrome who has severe ocular abnormalities including bilateral microphthalmia, cataract, and retinal aplasia.

  2. CT guided diagnostic foot injections

    International Nuclear Information System (INIS)

    Saifuddin, A.; Abdus-Samee, M.; Mann, C.; Singh, D.; Angel, J.C.

    2005-01-01

    AIM: To describe a CT technique for guiding diagnostic and therapeutic injections in the hind- and mid-foot. MATERIALS AND METHODS: Over a period of 50 months, 28 individuals were referred for diagnostic and therapeutic hind- and mid-foot injections before possible arthrodesis. A CT technique was developed that allowed entry into the various joints using a vertical approach. Numbers of joints injected were as follows: posterior subtalar, 21; talonavicular, 4; calcaneonavicular, calcaneocuboid, navicular-cuneiform and 5th metatarsocuboid joints, 1 each. RESULTS: All injections but one were technically successful. Significant relief of symptoms was noted by 16 participants, whereas for 9 there was no improvement and for 3 a partial response was achieved. CONCLUSION: CT is a simple and safe alternative to fluoroscopy for guiding diagnostic and therapeutic foot injections, and may be the technique of choice in cases of disordered anatomy

  3. Ophthalmological findings in infants with microcephaly and presumable intra-uterus Zika virus infection

    Directory of Open Access Journals (Sweden)

    Camila V. Ventura

    2016-02-01

    Full Text Available ABSTRACT Purpose: In 2015, a twenty-fold increase in the prevalence of microcephaly in Brazil was reported, and the Ministry of Health associated this abnormal prevalence with the maternal-fetal Zika virus (ZIKV transmission. Methods: We assessed the ophthalmological findings of ten mothers and their infants that had been clinically diagnosed with ZIKV-related microcephaly and presented ocular abnormalities, born from May to December 2015. Results: Seven mothers (70.0% referred symptoms during pregnancy (malaise, rash and arthralgia, of which six (85.7% were in the first trimester. At the time of exam, no ophthalmological abnormalities were identified in the mothers and they did not report ocular symptoms during pregnancy. Serology was negative in all infants for Toxoplasmosis, Rubella, Cytomegalovirus, Syphilis and Human Immunodeficiency Viruses. Ocular findings included macular alterations (gross pigment mottling and/or chorioretinal atrophy in fifteen eyes (75.0%, and optic nerve abnormalities (hypoplasia with double-ring sign, pallor, and/or increased cup-to-disk ratio in nine eyes (45.0%. Conclusions: Patients presented normal anterior segment and important macular and optic nerve abnormalities. Further studies will assess the visual significance of these alterations.

  4. Stem Cell Ophthalmology Treatment Study (SCOTS for retinal and optic nerve diseases: a preliminary report

    Directory of Open Access Journals (Sweden)

    Jeffrey N Weiss

    2015-01-01

    Full Text Available In this report, we present the results of a single patient with optic neuropathy treated within the Stem Cell Ophthalmology Treatment Study (SCOTS. SCOTS is an Institutional Review Board approved clinical trial and is the largest ophthalmology stem cell study registered at the National Institutes of Health to date- www.clinicaltrials.gov Identifier NCT 01920867. SCOTS utilizes autologous bone marrow-derived stem cells in the treatment of optic nerve and retinal diseases. Pre- and post-treatment comprehensive eye exams were independently performed at the Wilmer Eye Institute at the Johns Hopkins Hospital, USA. A 27 year old female patient had lost vision approximately 5 years prior to enrollment in SCOTS. Pre-treatment best-corrected visual acuity at the Wilmer Eye Institute was 20/800 Right Eye (OD and 20/4,000 Left Eye (OS. Four months following treatment in SCOTS, the central visual acuity had improved to 20/100 OD and 20/40 OS.

  5. Optical coherence tomography angiography: Technical principles and clinical applications in ophthalmology

    Directory of Open Access Journals (Sweden)

    Ahmed M Hagag

    2017-01-01

    Full Text Available Optical coherence tomography angiography (OCTA is a functional extension of OCT that provides information on retinal and choroidal circulations without the need for dye injections. With the recent development of high-speed OCT systems and efficient algorithms, OCTA has become clinically feasible. In this review article, we discuss the technical principles of OCTA, including image processing and artifacts, and its clinical applications in ophthalmology. We summarize recent studies which qualitatively or quantitatively assess disease presentation, progression, and/or response to treatment.

  6. Procedural aspects of the organization of the comprehensive European Board of Ophthalmology Diploma examination

    Directory of Open Access Journals (Sweden)

    Danny G.P. Mathysen

    2016-07-01

    Full Text Available The comprehensive European Board of Ophthalmology Diploma (EBOD examination is one of 38 European medical specialty examinations. This review aims at disclosing the specific procedures and content of the EBOD examination. It is a descriptive study summarizing the present organization of the EBOD examination. It is the 3rd largest European postgraduate medical assessment after anaesthesiology and cardiology. The master language is English for the Part 1 written test (knowledge test with 52 modified type X multiple-choice questions (in the past the written test was also available in French and German. Ophthalmology training of minimum 4 years in a full or associated European Union of Medical Specialists (UEMS member state is a prerequisite. Problem-solving skills are tested in the Part 2 oral assessment, which is a viva of 4 subjects conducted in English with support for native language whenever feasible. The comprehensive EBOD examination is one of the leading examinations organized by UEMS European Boards or Specialist Sections from the point of number of examinees, item banking, and item contents.

  7. Effect of digital problem-based learning cases on student learning outcomes in ophthalmology courses.

    Science.gov (United States)

    Kong, Jun; Li, Xiaoyan; Wang, Youdong; Sun, Wei; Zhang, Jinsong

    2009-09-01

    To assess the impact of digital problem-based learning (PBL) cases on student learning in ophthalmology courses. Ninety students were randomly divided into 3 classes (30 students per class). The first class studied under a didactic model. The other 2 classes were divided into 6 groups (10 students per group) and received PBL teaching; 3 groups studied via cases presented in digital form and the others studied via paper-form cases. The results of theoretical and case analysis examinations were analyzed using the chi(2) test. Student performance on the interval practice was analyzed using the Kruskal-Wallis test. Questionnaires were used to evaluate student and facilitator perceptions. Students in the digital groups exhibited better performance in the practice procedures according to tutorial evaluations compared with the other groups (P digital groups (vs 73% in the paper groups) noted that the cases greatly stimulated their interest. Introducing PBL into ophthalmology could improve educational quality and effectiveness. Digital PBL cases stimulate interest and motivate students to further improve diagnosis and problem-handling skills.

  8. Sportsmen’s Groin—Diagnostic Approach and Treatment With the Minimal Repair Technique

    Science.gov (United States)

    Muschaweck, Ulrike; Berger, Luise Masami

    2010-01-01

    Context: Sportsmen’s groin, also called sports hernia and Gilmore groin, is one of the most frequent sports injuries in athletes and may place an athletic career at risk. It presents with acute or chronic groin pain exacerbated with physical activity. So far, there is little consensus regarding pathogenesis, diagnostic criteria, or treatment. There have been various attempts to explain the cause of the groin pain. The assumption is that a circumscribed weakness in the posterior wall of the inguinal canal, which leads to a localized bulge, induces a compression of the genital branch of the genitofemoral nerve, considered responsible for the symptoms. Methods: The authors developed an innovative open suture repair—the Minimal Repair technique—to fit the needs of professional athletes. With this technique, the circumscribed weakness of the posterior wall of the inguinal canal is repaired by an elastic suture; the compression on the nerve is abolished, and the cause of the pain is removed. In contrast with that of common open suture repairs, the defect of the posterior wall is not enlarged, the suture is nearly tension free, and the patient can return to full training and athletic activity within a shorter time. The outcome of patients undergoing operations with the Minimal Repair technique was compared with that of commonly used surgical procedures. Results: The following advantages of the Minimal Repair technique were found: no insertion of prosthetic mesh, no general anesthesia required, less traumatization, and lower risk of severe complications with equal or even faster convalescence. In 2009, a prospective cohort of 129 patients resumed training in 7 days and experienced complete pain relief in an average of 14 days. Professional athletes (67%) returned to full activity in 14 days (median). Conclusion: The Minimal Repair technique is an effective and safe way to treat sportsmen’s groin. PMID:23015941

  9. Teaching Neuro-Ophthalmology in the Asia-Pacific Region and China: A Personal Perspective.

    Science.gov (United States)

    Crompton, John

    2015-12-01

    Over the last 30 years, I have been involved in a number of projects helping to educate and train local ophthalmologists in many parts of Asia and the Pacific Islands, which lack adequate training and service in neuro-ophthalmology. In this article, I offer an overview of a number of different teaching initiatives and offer practical suggestions to anyone who might wish to become involved.

  10. Diagnostic planning in JT-60 project

    International Nuclear Information System (INIS)

    Matoba, Tohru; Suzuki, Yasuo; Funahashi, Akimasa; Itagaki, Tokiyoshi

    1977-08-01

    The diagnostic plans of JT-60 were made along with design of the main machine. Basic requirements of the diagnostic program are (1) multiple measurement of respective plasma parameters, (2) efficient usage of the discharge, (3) capable data acquisition system, (4) high reliability of the diagnostic equipments, and (5) systematic development of new diagnostic techniques. Dimensions of the diagnostic ports were determined in detailed design of the vacuum vessel, anticipating the possible diagnostic methods. The proposed diagnostic systems and the plans are shown in table and figures respectively. Problems in the diagnostics are also described. (auth.)

  11. Lasers in ophthalmology: achievements and new directions

    Science.gov (United States)

    Carstocea, Benone D.; Apostol, Silvia; Gafencu, Otilia L.

    1995-03-01

    The main characteristics of the laser radiations are: directivity, monochromaticity and spatially and temporally coherence. Using the aggregation state as a criterion for classification, we describe solid, liquid and gaseous active media. Concerning the methods used to realize the population inversion, we also describe: optically, electrically and high energy particles pumped lasers. Depending on the laser media and the mode of excitation, a laser may operate in multiple ways: the continuous-wave operation, the long-pulsed operation, the Q-switched mode of operation and the mode-locked operation. The interaction of laser radiations with the living matter is based upon four main effects: the thermal, mechanical, electrical and biological effect. The main field of therapeutical use of lasers are: the management of lid tumors and intraocular tumors, dacryocystorhinostomy, the treatment of diabetic retinopathy, thromboembolic retinal syndromes, inflammatory choriretinal disease, chorioroetinal degenerations, retinal angimatosis, retinal breaks and retinal detachment, corneal diseases, glaucoma, lens diseases. Laser has also nontherapeutical applications in diagnosis and prognosis of ophthalmologic diseases.

  12. A thermal technique for local ultrasound intensity measurement: part 2. Application to exposimetry on a medical diagnostic device

    International Nuclear Information System (INIS)

    Wilkens, V

    2010-01-01

    Acoustic output measurements on medical ultrasound equipment are usually performed using radiation force balances to determine the output power and using hydrophones to determine pressure and intensity parameters. The local temporal-average ultrasound intensity can be measured alternatively by thermal sensors. The technique was described and prototype sensors were characterized in a preceding paper. Here, the application of such a thermal intensity sensor to the output beam characterization of a typical medical diagnostic device is described. Two transducers, a 7.5 MHz linear array and a 3.5 MHz convex array were investigated in different operating modes. For comparison, hydrophone measurements were also performed. If the spatial averaging effect is taken into account, good agreement is found between both measurement methods. The maximum deviations of the spatial-peak temporal-average intensities I SPTA obtained with the thermal sensor from the corresponding hydrophone-based results were below 12%. The simple thermal technique offers advantages for intensity measurements especially in the case of scanning and combined modes of the diagnostic device, where the synchronization between hydrophone measurements and the complex pulse emission pattern can be difficult

  13. Effects of optical diagnostic techniques on the accuracy of laminar flame speeds measured from Bunsen flames: OH* chemiluminescence, OH-PLIF and acetone/kerosene-PLIF

    Science.gov (United States)

    Wu, Yi; Modica, Vincent; Yu, Xilong; Li, Fei; Grisch, Frédéric

    2018-01-01

    The effects of optical diagnostic techniques on the accuracy of laminar flame speed measured from Bunsen flames were investigated. Laminar flame speed measurements were conducted for different fuel/air mixtures including CH4/air, acetone/air and kerosene (Jet A-1)/air in applying different optical diagnostic techniques, i.e. OH* chemiluminescence, OH-PLIF and acetone/kerosene-PLIF. It is found that the OH* chemiluminescence imaging technique cannot directly derive the location of the outer edge of the fresh gases and it is necessary to correct the position of the OH* peak to guarantee the accuracy of the measurements. OH-PLIF and acetone/kerosene-PLIF respectively are able to measure the disappearance of the fresh gas contour and the appearance of the reaction zone. It shows that the aromatic-PLIF technique gives similar laminar flame speed values when compared with those obtained from corrected OH* chemiluminescence images. However, discrepancies were observed between the OH-PLIF and the aromatic-PLIF techniques, in that OH-PLIF slightly underestimates laminar flame speeds by up to 5%. The difference between the flame contours obtained from different optical techniques are further analysed and illustrated with 1D flame structure simulation using detailed kinetic mechanisms.

  14. Molecular diagnostics of periodontitis.

    Science.gov (United States)

    Korona-Głowniak, Izabela; Siwiec, Radosław; Berger, Marcin; Malm, Anna; Szymańska, Jolanta

    2017-01-28

    The microorganisms that form dental plaque are the main cause of periodontitis. Their identification and the understanding of the complex relationships and interactions that involve these microorganisms, environmental factors and the host's health status enable improvement in diagnostics and targeted therapy in patients with periodontitis. To this end, molecular diagnostics techniques (both techniques based on the polymerase chain reaction and those involving nucleic acid analysis via hybridization) come increasingly into use. On the basis of a literature review, the following methods are presented: polymerase chain reaction (PCR), real-time polymerase chain reaction (real-time PCR), 16S rRNA-encoding gene sequencing, checkerboard and reverse-capture checkerboard hybridization, microarrays, denaturing gradient gel electrophoresis (DGGE), temperature gradient gel electrophoresis (TGGE), as well as terminal restriction fragment length polymorphism (TRFLP) and next generation sequencing (NGS). The advantages and drawbacks of each method in the examination of periopathogens are indicated. The techniques listed above allow fast detection of even small quantities of pathogen present in diagnostic material and prove particularly useful to detect microorganisms that are difficult or impossible to grow in a laboratory.

  15. Pocket book on setting techniques for medical imaging. X-ray diagnostics, angiography, CT, MRT. 4. rev. and enl. ed.; Taschenatlas Einstelltechnik. Roentgendiagnostik, Angiografie, CT, MRT

    Energy Technology Data Exchange (ETDEWEB)

    Moeller, Torsten B.; Reif, Emil [Caritas-Krankenhaus, Dillingen/Saar (Germany)

    2009-07-01

    The pocketbook on setting techniques for medical imaging is concerned with the problem to prepare appropriate images for diagnostic purposes using modern high-technology instruments like x-ray diagnostics, angiography, computerized tomography and magnetic resonance tomography. The following issues are covered: Head, spinal column, upper extremities, lower extremities, thorax, gastrointestinal tract, intravenous organ examination, angiography, computerized tomography, NMR imaging.

  16. Applying Diagnostics to Enhance Cable System Reliability (Cable Diagnostic Focused Initiative, Phase II)

    Energy Technology Data Exchange (ETDEWEB)

    Hartlein, Rick [Georgia Tech Research Corporation (GTRC), Atlanta, GA (United States). National Electric Energy Testing, Research and Applications Center (NEETRAC); Hampton, Nigel [Georgia Tech Research Corporation (GTRC), Atlanta, GA (United States). National Electric Energy Testing, Research and Applications Center (NEETRAC); Perkel, Josh [Georgia Tech Research Corporation (GTRC), Atlanta, GA (United States). National Electric Energy Testing, Research and Applications Center (NEETRAC); Hernandez, JC [Univ. de Los Andes, Merida (Venezuela); Elledge, Stacy [Georgia Tech Research Corporation (GTRC), Atlanta, GA (United States). National Electric Energy Testing, Research and Applications Center (NEETRAC); del Valle, Yamille [Georgia Tech Research Corporation (GTRC), Atlanta, GA (United States). National Electric Energy Testing, Research and Applications Center (NEETRAC); Grimaldo, Jose [Georgia Inst. of Technology, Atlanta, GA (United States). School of Electrical and Computer Engineering; Deku, Kodzo [Georgia Inst. of Technology, Atlanta, GA (United States). George W. Woodruff School of Mechanical Engineering

    2016-02-01

    The Cable Diagnostic Focused Initiative (CDFI) played a significant and powerful role in clarifying the concerns and understanding the benefits of performing diagnostic tests on underground power cable systems. This project focused on the medium and high voltage cable systems used in utility transmission and distribution (T&D) systems. While many of the analysis techniques and interpretations are applicable to diagnostics and cable systems outside of T&D, areas such as generating stations (nuclear, coal, wind, etc.) and other industrial environments were not the focus. Many large utilities in North America now deploy diagnostics or have changed their diagnostic testing approach as a result of this project. Previous to the CDFI, different diagnostic technology providers individually promoted their approach as the “the best” or “the only” means of detecting cable system defects.

  17. Guiding role of typical cases in clinical training for ophthalmology professional degree graduate students

    Directory of Open Access Journals (Sweden)

    Zhe Wang

    2014-05-01

    Full Text Available With the change of the concept of graduate enrollment, the recruiting proportion of clinical medicine professional degree graduate students is more and more, and the training of professional degree graduate students is increasingly focusing on practical. In our experience in clinical training for ophthalmology professional degree graduate students, increasing the ward clinical practice time is important. For particular emphasis on the guiding role of the typical cases, each professional group combined their professional characteristics of the typical cases to instruct the graduate students, training their clinical diagnosis and treatment ability, training their microsurgical techniques. From clinical medical writing, record summary, literature review, professional degree graduate students could expand their knowledge structure, practice their thesis writing ability. Based on the typical cases, expansion of knowledge coverage, they could improve the ability of diagnosis and treatment for special disease cases. In this rigorous training system, professional degree graduate students can learn by analogy, and focus on typical cases to get the most intuitive panoramic understanding of the diseases, with a minimum of time to master the most clinical knowledge, to enrich clinical experience, and to lay the foundation for future work in the assessment.

  18. Risk estimation in association with diagnostic techniques in the nuclear medicine service of the Camaguey Ciego de Avila Territory

    International Nuclear Information System (INIS)

    Barrerras, C.A.; Brigido, F.O.; Naranjo, L.A.; Lasserra, S.O.; Hernandez Garcia, J.

    1999-01-01

    The nuclear medicine service at the Maria Curie Oncological Hospital, Camaguey, has experience of over three decades in using radiofarmaceutical imaging agents for diagnosis. Although the clinical risk associated with these techniques is negligible, it is necessary to evaluate the effective dose administered to the patient due to the introduction of radioactive substances into the body. The study of the dose administered to the patient provides useful data for evaluating the detriment associated with this medical practice, its subsequently optimization and consequently, for minimizing the stochastic effects on the patient. The aim of our paper is to study the collective effective dose administered by nuclear medicine service to Camaguey and Ciego de Avila population from 1995 to 1998 and the relative contribution to the total annual effective collective dose of the different diagnostic examinations. The studies were conducted on the basis of statistics from nuclear medicine examinations given to a population of 1102353 inhabitants since 1995. The results show that the nuclear medicine techniques of neck examinations with 1168.8 Sv man (1.11 Sv/expl), thyroid explorations with 119.6 Sv man (55.5 mSv/expl) and iodide uptake with 113.7 Sv man (14.0 mSv/expl) are the main techniques implicated in the relative contribution to the total annual effective collective dose of 1419.5 Sv man. The risk estimation in association with diagnostic techniques in the nuclear medicine service studied is globally low (total detriment: 103.6 as a result of 16232 explorations), similar to other published data

  19. Mersey deanery ophthalmology trainees' views of the objective assessment of surgical and technical skills (OSATS) workplace-based assessment tool.

    Science.gov (United States)

    Tsagkataki, Myrto; Choudhary, Anshoo

    2013-02-01

    Objective assessment of surgical and technical skills (OSATS) workplace-based assessment tool is now mandatory during ophthalmology speciality training in the United Kingdom. The opinions of those undergoing this assessment have not been formally sought. This study evaluated the views of ophthalmology trainees on OSATS assessment as applied to cataract surgery. A questionnaire was circulated to 34 ophthalmology speciality trainees of the Mersey deanery. A total of 28 responses were received. The most positive aspects of the process identified were feedback, learning and opportunity for reflective practice. The most negative aspects were time constraints, assessor's availability and case selection. Of the trainees, 93 % mentioned that no previous agreed action was taken into consideration when filling in subsequent forms and their performance was not discussed in their annual summative assessment. This study highlights important aspects of trainees' perceptions of OSATS. Trainees appreciate the formative aspects of OSATS assessment. Some problems came to light, which can be resolved by specification of standards, training of assessors, and commitment from both trainers and trainees. Changes are needed to allow demonstration of surgical progression with time. The issues identified here will be relevant to other specialities as well. A larger survey would be beneficial.

  20. Comparative value of diagnostic imaging techniques in a cat with exophthalmos

    International Nuclear Information System (INIS)

    Ramsey, D.T.; Gerding, P.A. Jr.; Losonsky, J.M.; Kuriashkin, I.V.; Clarkson, R.D.

    1994-01-01

    A mass that appeared to originate from the frontal bone and extended into retrobulbar tissues of the light orbit was imaged in a cat using ultrasound, skull radiographs, computed tomography, and magnetic resonance imaging. The cat was presented with ventrolateral strabismus, exophthalmos, and elevated nictitans membrane of the tight eye. The mass was not delineated entirely after orbital echography and survey radiography of the skull was performed. Cytologic examination of fine-needle aspirate of the mass was suggestive of a neoplastic disease. Results of computed tomography indicated lysis of the calvarium but did not delineate borders of the mass in the calvarium. Magnetic resonance imaging was then used to confirm borders of the neoplasm. Magnetic resonance imaging was the only imaging technique that delineated the entire border of the neoplasm, including in the calvarium, when compared to postmortem evaluation. Results of orbital echography, skull radiographs, or computed tomography, when used as the only diagnostic imaging modality, must be interpreted with caution when evaluating borders of retrobulbar neoplasia prior to surgical planning

  1. Neuro-ophthalmologic evaluation, quality of life, and functional disability in patients with MS.

    Science.gov (United States)

    Garcia-Martin, Elena; Rodriguez-Mena, Diego; Herrero, Raquel; Almarcegui, Carmen; Dolz, Isabel; Martin, Jesus; Ara, Jose R; Larrosa, Jose M; Polo, Vicente; Fernández, Javier; Pablo, Luis E

    2013-07-02

    To evaluate correlations between longitudinal changes in neuro-ophthalmologic measures and quality of life (QOL) and disability in patients with multiple sclerosis (MS), using optical coherence tomography (OCT), visual evoked potentials (VEP), and visual field examination. Fifty-four patients with relapsing-remitting MS were enrolled in this study and underwent Multiple Sclerosis Quality of Life questionnaire (54 items) (MSQOL-54) and Expanded Disability Status Scale (EDSS) evaluation, as well as complete neuro-ophthalmologic examination including visual field testing and retinal nerve fiber layer (RNFL) measurements using Cirrus and Spectralis OCT and VEP. All patients were re-evaluated at 12, 24, and 36 months. Logistical regression was performed to analyze which measures, if any, could predict QOL. Overall, RNFL thickness results at the baseline evaluation were significantly different from those at 3 years (p ≤ 0.05), but there were no differences in functional measures (visual acuity, contrast sensitivity, color vision, visual field, and VEP). A reduced MSQOL-54 score was associated with an increase in EDSS score and a decrease in both functional and structural parameters. Patients with longer MS duration presented with a lower MSQOL-54 score (reduction in QOL). Patients with progressive axonal loss as seen in RNFL results had a lower QOL and more functional disability.

  2. Diagnostic examination of the urethra in the female and double-balloon urethrography as a diagnostic method

    International Nuclear Information System (INIS)

    Madeja, C.; Mutze, S.; Poetzschke, B.; Tunn, R.; Heinrich, G.; Hamm, B.

    1997-01-01

    The double-balloon urethrography can be recommended as an efficient diagnostic method for examination of the urethra in the female patient. Because of its improved controllability, retrograde application of the contrast agent is superior to other techniques. Complications can be avoided by maintaining constant pressure during contrast agent application. The few commercially available double-balloon instruments suffer from a number of deficiencies which are the reason for this technique having met with low acceptance, thus being only rarely applied. In addition, application of the instrument is not easy. Nevertheless, this diagnostic technique would deserve much more frequent application. (orig.) [de

  3. Multi-method automated diagnostics of rotating machines

    Science.gov (United States)

    Kostyukov, A. V.; Boychenko, S. N.; Shchelkanov, A. V.; Burda, E. A.

    2017-08-01

    The automated machinery diagnostics and monitoring systems utilized within the petrochemical plants are an integral part of the measures taken to ensure safety and, as a consequence, the efficiency of these industrial facilities. Such systems are often limited in their functionality due to the specifics of the diagnostic techniques adopted. As the diagnostic techniques applied in each system are limited, and machinery defects can have different physical nature, it becomes necessary to combine several diagnostics and monitoring systems to control various machinery components. Such an approach is inconvenient, since it requires additional measures to bring the diagnostic results in a single view of the technical condition of production assets. In this case, we mean by a production facility a bonded complex of a process unit, a drive, a power source and lines. A failure of any of these components will cause an outage of the production asset, which is unacceptable. The purpose of the study is to test a combined use of vibration diagnostics and partial discharge techniques within the diagnostic systems of enterprises for automated control of the technical condition of rotating machinery during maintenance and at production facilities. The described solutions allow you to control the condition of mechanical and electrical components of rotating machines. It is shown that the functionality of the diagnostics systems can be expanded with minimal changes in technological chains of repair and operation of rotating machinery. Automation of such systems reduces the influence of the human factor on the quality of repair and diagnostics of the machinery.

  4. Far infrared fusion plasma diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Luhmann, N.C. Jr.; Peebles, W.A.

    1990-01-01

    Over the last several years, reflectometry has grown in importance as a diagnostic for both steady-state density Profiles as well as for the investigation of density fluctuations and turbulence. As a diagnostic for density profile measurement, it is generally believed to be well understood in the tokamak environment. However, its use as a fluctuation diagnostic is hampered by a lack of quantitative experimental understanding of its wavenumber sensitivity and spatial resolution. Several researchers, have theoretically investigated these questions. However, prior to the UCLA laboratory investigation, no group has experimentally investigated these questions. Because of the reflectometer's importance to the world effort in understanding plasma turbulence and transport, UCLA has, over the last year, made its primary Task IIIA effort the resolution of these questions. UCLA has taken the lead in a quantitative experimental understanding of reflectometer data as applied to the measurement of density fluctuations. In addition to this, work has proceeded on the design, construction, and installation of a reflectometer system on UCLA's CCT tokamak. This effort will allow a comparison between the improved confinement regimes (H-mode) observed on both the DIII-D and CCT machines with the goal of achieving a physics understanding of the phenomena. Preliminary investigation of a new diagnostic technique to measure density profiles as a function of time has been initiated at UCLA. The technique promises to be a valuable addition to the range of available plasma diagnostics. Work on advanced holographic reflectometry technique as applied to fluctuation diagnostics has awaited a better understanding of the reflectometer signal itself as discussed above. Efforts to ensure the transfer of the diagnostic developments have continued with particular attention devoted to the preliminary design of a multichannel FIR interferometer for MST.

  5. On textual and contextual position of the ophthalmological treatise of bodhisattva nāgārjuna.

    Science.gov (United States)

    Kim, Seongsu; Kang, Sungyong

    2013-04-01

    Medical knowledge in India began to be introduced to China in earliest from the Later Han Dynasty period to the times of Wei-Qin and South & North Dynasties. This is proved by many Buddhist medical books appeared in those days. Of the contents of Indian medicine, the theory of four major elements affected Chinese medicine more than did the theory of body fluids. Based on the theory of four major elements that was began to be introduced in Fú shuō fú yī jīng, an attempt to establish a new medical system was made in Zhŏu hòu băi yīfāng written by Táo Hóng-jĭng and Sūn Sī-miăo who tried to develop etiology further but could not achieve any great outcomes. Unlike the foregoing situation, Indian medicine aroused a large echo in China in the field of ophthalmology with ophthalmological knowledge mentioned in Suśrutasa hitā and 'Jīnzhēn-shù'(cataract couching) introduced as a surgical treatment of cataract. The Suśrutasa hitā which is one of the three major texts of Indian medicine contains additional information on surgical operations not introduced in the Carakasa hitā. The technique of cataract surgery was particularly popular in the Tang and Song dynasty periods in China under the name Lóng shù pú sà yăn lùn(The Ophthalmological Treatise of Bodhisattva Nāgārjuna) or Lóng shù lùn and was even designated as a subject to educate medical officers. While the original text of Lóng shù pú sà yăn lùn was not handed down, the first testimony that show the trace of the introduction of this text into China was the Tiān zhú jīng lùn yăn mentioned in Wài tái mì yào(Arcane Essential from the Imperial Library) written by Wang Tao. Long shàng dào ren who was mentioned as the compiler of the book is assumed to be Lóng shù. Although Tiān zhú jīng lùn yăn introduced anatomical knowledge about the eyeball that could have not been in the traditional Chinese medicine, this book has only limited quantity of information in this

  6. Unique identification code for medical fundus images using blood vessel pattern for tele-ophthalmology applications.

    Science.gov (United States)

    Singh, Anushikha; Dutta, Malay Kishore; Sharma, Dilip Kumar

    2016-10-01

    Identification of fundus images during transmission and storage in database for tele-ophthalmology applications is an important issue in modern era. The proposed work presents a novel accurate method for generation of unique identification code for identification of fundus images for tele-ophthalmology applications and storage in databases. Unlike existing methods of steganography and watermarking, this method does not tamper the medical image as nothing is embedded in this approach and there is no loss of medical information. Strategic combination of unique blood vessel pattern and patient ID is considered for generation of unique identification code for the digital fundus images. Segmented blood vessel pattern near the optic disc is strategically combined with patient ID for generation of a unique identification code for the image. The proposed method of medical image identification is tested on the publically available DRIVE and MESSIDOR database of fundus image and results are encouraging. Experimental results indicate the uniqueness of identification code and lossless recovery of patient identity from unique identification code for integrity verification of fundus images. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  7. Ethical and deontological dominants in ophthalmology

    Directory of Open Access Journals (Sweden)

    O. M. Panko

    2014-02-01

    Full Text Available In the article the ethical and deontological dominants as scientific and practical strategy that prevents the medical errors, and humanization doctor-patient relationship through a formation of culture of communication are presented. Ophthalmology as a branch of practical and scientific medicine requires special relationship between doctor and patient, and because of this it also requires particular ethical and deontological interpretation. Formal signs of ethics laws concerning ophthalmic practice aren’t worth anything in case of unskilled diagnosis and treatment. Possibility of errors on the part of the doctor-ophthalmologist while aiding a patient is of a special importance. In planed and in urgent cases irreparable flaws are not excluded. Consideration should be given, in particular, to the errors in the initial examination, insufficient amount of additional methods of examination, overdiagnosis, errors in determining the treatment strategy (conservative or surgical and others. Identification and analysis of the errors in order to prevent them is the ethical imperative in medical practice and effective way to improve clinical medicine. The author of the article describes the causes of errors, indicating that they are objective and subjective. The first are related to the change of views on the treatment of a certain disease. The complex of therapeutic measures, that was considered the most rational until recently, can be proven as wrong from the perspective of the latest achievements of science. Mistakes made by doctors in their communication with patients as a result of not following the basic deontological principles are also included here. In addition, the classification of medical errors on deontological, diagnostic, therapeutic is made and their essence is analyzed in the article. The violation of the principles of appropriate behavior of the doctor in treating the patient, that is not following the ethics of medical practice by the

  8. Adequacy of the ophthalmology workforce under Ontario's Local Health Integration Networks.

    Science.gov (United States)

    Lin, Tony; Xu, Mark; Hooper, Philip L

    2016-06-01

    To determine the current distribution of ophthalmologists across Ontario's Local Health Integration Networks (LHINs) and the influence on LHIN-specific cataract surgery wait times. Cross-sectional study. Ophthalmologists listed in the College of Physicians and Surgeons (CPSO) database and the Canadian population. A list of ophthalmologists and their practice locations were obtained from the CPSO website. The total population count for Ontario was obtained from the Statistics Canada census. The population counts for the population aged 65 years and older were generated using the Canadian Socioeconomic Information Management System (CANSIM) table 109-5425. Cataract surgery wait times were obtained from the Ontario Ministry of Health. Statistical analysis was completed using Microsoft Excel using StatPlus software. There are currently 3.28 ophthalmologists per 100 000 total population in Ontario. LHIN-specific ratios ranged from 8.87 (Toronto Central) to 1.67 (Central West), with 3 out of 14 LHINs having met the previously recommended ratio of 3.37. Median cataract surgery wait times ranged from 30 to 72 days. Although the number of cataract surgeries performed was positively correlated with the population aged 65 years and older (p < 0.001), there was no statistically significant association between wait times and number of cataract cases per 1000 population (p = 0.41). Although Ontario appears to have a sufficient number of ophthalmologists overall, there is significant variation in the distribution of the ophthalmology workforce at the LHIN level. This variation did not appear to significantly influence LHIN-specific cataract surgery wait times. Copyright © 2016 Canadian Ophthalmological Society. Published by Elsevier Inc. All rights reserved.

  9. Molecular diagnostics of periodontitis

    Directory of Open Access Journals (Sweden)

    Izabela Korona-Głowniak

    2017-01-01

    Full Text Available The microorganisms that form dental plaque are the main cause of periodontitis. Their identification and the understanding of the complex relationships and interactions that involve these microorganisms, environmental factors and the host’s health status enable improvement in diagnostics and targeted therapy in patients with periodontitis. To this end, molecular diagnostics techniques (both techniques based on the polymerase chain reaction and those involving nucleic acid analysis via hybridization come increasingly into use. On the basis of a literature review, the following methods are presented: polymerase chain reaction (PCR, real-time polymerase chain reaction (real-time PCR, 16S rRNA-encoding gene sequencing, checkerboard and reverse-capture checkerboard hybridization, microarrays, denaturing gradient gel electrophoresis (DGGE, temperature gradient gel electrophoresis (TGGE, as well as terminal restriction fragment length polymorphism (TRFLP and next generation sequencing (NGS. The advantages and drawbacks of each method in the examination of periopathogens are indicated. The techniques listed above allow fast detection of even small quantities of pathogen present in diagnostic material and prove particularly useful to detect microorganisms that are difficult or impossible to grow in a laboratory.

  10. [Surgeon and eye doctor Caspar Stromayr and the ophthalmological illustrations in his "Practica copiosa" (1559)].

    Science.gov (United States)

    Nover, A; Kümmel, W F

    1984-11-01

    In 1559 Caspar Stromayr wrote a richly illustrated book about hernias and their treatment. The manuscript also includes 3 chapters of a book on ophthalmological diseases which, however, was never published. In addition, it contains 6 separate watercolor illustrations of eye diseases, though without any explanatory texts. The authors attempt to interpret these first colored pictures of eye diseases.

  11. Nuclear diagnostics in support of ICF experiments

    International Nuclear Information System (INIS)

    Moran, M.J.; Hall, J.

    1996-01-01

    As the yields of Inertial Confinement Fusion (ICF) experiments increase to NIF levels new diagnostic techniques for studying details of fusion burn behavior will become feasible. The new techniques will provide improved measurements of fusion burn temperature and history. Improved temperature measurements might be achieved with magnetic spectroscopy of fusion neutrons. High-bandwidth fusion reaction history will be measured with fusion-specific γ-ray diagnostics. Additional energy-resolved γ-ray might be able to study a selection of specific behaviors during fusion burn. Present ICF yields greater than 10 13 neutrons are sufficient to demonstrate the basic methods that underlie the new techniques. As ICF yields increase, the diagnostics designs adjusted accordingly in order to provide clear and specific data on fusion burn performance

  12. Do Anesthetic Techniques Influence the Threshold for Glomerular Capillary Hemorrhage Induced in Rats by Contrast-Enhanced Diagnostic Ultrasound?

    Science.gov (United States)

    Miller, Douglas L; Lu, Xiaofang; Fabiilli, Mario; Dou, Chunyan

    2016-02-01

    Glomerular capillary hemorrhage can be induced by ultrasonic cavitation during contrast-enhanced diagnostic ultrasound (US) exposure, an important nonthermal US bioeffect. Recent studies of pulmonary US exposure have shown that thresholds for another nonthermal bioeffect of US, pulmonary capillary hemorrhage, is strongly influenced by whether xylazine is included in the specific anesthetic technique. The objective of this study was to determine the influence of xylazine on contrast-enhanced diagnostic US-induced glomerular capillary hemorrhage. In this study, anesthesia with ketamine only was compared to ketamine plus xylazine for induction of glomerular capillary hemorrhage in rats by 1.6-MHz intermittent diagnostic US with a microsphere contrast agent (similar to Definity; Lantheus Medical Imaging, Inc, North Billerica, MA). Glomerular capillary hemorrhage was measured as a percentage of glomeruli with hemorrhage found in histologic sections for groups of rats scanned at different peak rarefactional pressure amplitudes. There was a significant difference between the magnitude of the glomerular capillary hemorrhage between the anesthetics at 2.3 MPa, with 45.6% hemorrhage for ketamine only, increasing to 63.2% hemorrhage for ketamine plus xylazine (P Ultrasound in Medicine.

  13. Back pain in ophthalmology: National survey of Indian ophthalmologists

    Directory of Open Access Journals (Sweden)

    Ramesh Venkatesh

    2017-01-01

    Full Text Available Purpose: The aim is to assess the prevalence, severity, and associations of back pain among Indian ophthalmologists. Methods: A self-reporting questionnaire was sent to ophthalmologists with valid e-mail addresses registered with the All India Ophthalmological Society. The survey was open for responses for 2 months. Results: A total of 651 (5.96% responses were obtained; 394 (61% males and 257 (39% females. Half (50% of responses were obtained from doctors belonging to 31–40 years' age group. Two hundred and thirty (35% of the ophthalmologists had height ranging from 161 to 170 cm and 443 (68% had weight ranging from 51 to 75 kg. Four hundred and eighty-one (73.8% of the respondents had <15 years of ophthalmic experience. Cataract (346; 53.1% and general ophthalmology (342; 52.5% were commonly practised by the ophthalmologists. Time spent in the outpatient department (OPD was 39.37 ± 16.32 h/week and in the operating theater 13.64 ± 9.89 h/week, respectively. Self-reported prevalence of back pain was 70.5%. Fully 49% of respondents had low back pain, followed by neck pain (33% and upper extremity symptoms (16%. Age <50 years (odds ratio [OR] = 2.4485, female gender (OR = 2.0265, long working hours in OPD (OR = 1.6524, and performing retinal lasers and indirect ophthalmoscopy (OR = 3.3251 showed positive association with back pain. The intolerable back pain was noted in <7% of the respondents. Around 398 (61% respondents felt that their back pain was exacerbated while doing work and 86.6% felt that up to 5 h/week was lost due to persistent backache. Yoga and some form of exercise (74.3% was practised to alleviate back pain. Conclusion: Back pain symptoms appear to be common among ophthalmologists. Awkward posture and prolonged working hours are responsible for developing back pain among ophthalmologists. Performing yoga and regular exercises, modifications in instrumentation and creating a larger workforce of eye care practitioners are needed

  14. A secure and synthesis tele-ophthalmology system.

    Science.gov (United States)

    Wei, Zhuo; Wu, Yongdong; Deng, Robert H; Yu, Shengsheng; Yao, Haixia; Zhao, Zhigang; Ngoh, Lek Heng; Han, Lim Tock; Poh, Eugenie W T

    2008-10-01

    This paper describes a secure and synthesis ophthalmology telemedicine system, referred to as TeleOph. Under a Secure Socket Layer (SSL) channel, patient prerecorded data can be safely transferred via the Internet. With encrypted videoconference and white-board, the system not only supports hospital-to-clinic consultation, but also supplies hospital-tohospital joint discussion. Based on Directshow technology (Microsoft Corporation, Redmond, WA), video cameras connected to the computer by firewire can be captured and controlled to sample video data. By using TWAIN technology, the system automatically identifies networked still cameras (on fundus and slitlamp devices) and retrieves images. All the images are stored in a selected format (such as JPEG, DICOM, BMP). Besides offline-transferring prerecorded data, the system also supplies online sampling of patient data (real-time capturing from remote places). The system was deployed at Tan Tock Seng Hospital, Singapore and Ang Mo Kio, Singapore, where 100 patients were enrolled in the system for examination. TeleOph can be successfully used for patient consultation, and hospital joint discussion. Meanwhile, TeleOph can supply both offline and online sampling of patient data.

  15. New Diagnostic, Launch and Model Control Techniques in the NASA Ames HFFAF Ballistic Range

    Science.gov (United States)

    Bogdanoff, David W.

    2012-01-01

    This report presents new diagnostic, launch and model control techniques used in the NASA Ames HFFAF ballistic range. High speed movies were used to view the sabot separation process and the passage of the model through the model splap paper. Cavities in the rear of the sabot, to catch the muzzle blast of the gun, were used to control sabot finger separation angles and distances. Inserts were installed in the powder chamber to greatly reduce the ullage volume (empty space) in the chamber. This resulted in much more complete and repeatable combustion of the powder and hence, in much more repeatable muzzle velocities. Sheets of paper or cardstock, impacting one half of the model, were used to control the amplitudes of the model pitch oscillations.

  16. LASER CORRELATION SPECTROSCOPY (LCS AND ITS CLINICAL PERSPECTIVES IN OPHTHALMOLOGY

    Directory of Open Access Journals (Sweden)

    Karganov Mikhail

    2015-12-01

    Full Text Available The method of laser correlation spectroscopy (LCS is based on the analysis of the spectrum of quasielastic light scatter during coherent monochromatic laser irradiation of micro-particles in biological fluids (blood serum, urine, oropharyngeal washout fluid, tear fluid etc.. Spectrum provides information on dynamic processes in the analyzed system: translation motion of scattering particles and their orientation and conformation dynamics. Special procedures of cluster analysis make it possible to find out to which linkage group a particular spectrum belongs. LCS allows evaluation of sub-fractional composition of biological fluids in a wide range of molecular sizes (from 1 to 10,000 nm, which determines principal novelty of this approach in ophthalmology.

  17. Quality of life in chemical warfare survivors with ophthalmologic injuries: the first results form Iran Chemical Warfare Victims Health Assessment Study.

    Science.gov (United States)

    Mousavi, Batool; Soroush, Mohammad Reza; Montazeri, Ali

    2009-01-19

    Iraq used chemical weapons extensively against the Iranians during the Iran-Iraq war (1980-1988). The aim of this study was to assess the health related quality of life (HRQOL) in people who had ophthalmologic complications due to the sulfur mustard gas exposure during the war. The Veterans and Martyrs Affair Foundation (VMAF) database indicated that there were 196 patients with severe ophthalmologic complications due to chemical weapons exposure. Of these, those who gave consent (n = 147) entered into the study. Quality of life was measured using the 36-item Short Form Health Survey (SF-36) and scores were compared to those of the general public. In addition logistic regression analysis was performed to indicate variables that contribute to physical and mental health related quality of life. The mean age of the patients was 44.8 (SD = 8.7) ranging from 21 to 75 years. About one-third of the cases (n= 50) reported exposure to chemical weapons more than once. The mean exposure duration to sulfur mustard gas was 21.6 years (SD = 1.2). The lowest scores on the SF-36 subscales were found to be: the role physical and the general health. Quality of life in chemical warfare victims who had ophthalmologic problems was significantly lower than the general public (P chemical warfare victims with ophthalmologic complications suffer from poor health related quality of life. It seems that the need for provision of health and support for this population is urgent. In addition, further research is necessary to measure health related quality of life in victims with different types of disabilities in order to support and enhance quality of life among this population.

  18. Pitfalls in diagnostic radiology

    International Nuclear Information System (INIS)

    Peh, Wilfred C.G.

    2015-01-01

    Only textbook to focus primarily on the topic of pitfalls in diagnostic radiology. Highlights the pitfalls in a comprehensive and systematic manner. Written by experts in different imaging modalities and subspecialties from reputable centers across the world. The practice of diagnostic radiology has become increasingly complex, with the use of numerous imaging modalities and division into many subspecialty areas. It is becoming ever more difficult for subspecialist radiologists, general radiologists, and residents to keep up with the advances that are occurring year on year, and this is particularly true for less familiar topics. Failure to appreciate imaging pitfalls often leads to diagnostic error and misinterpretation, and potential medicolegal problems. Diagnostic errors may be due to various factors such as inadequate imaging technique, imaging artifacts, failure to recognize normal structures or variants, lack of correlation with clinical and other imaging findings, and poor training or inexperience. Many, if not most, of these factors are potentially recognizable, preventable, or correctable. This textbook, written by experts from reputable centers across the world, systematically and comprehensively highlights the pitfalls that may occur in diagnostic radiology. Both pitfalls specific to different modalities and techniques and those specific to particular organ systems are described with the help of numerous high-quality illustrations. Recognition of these pitfalls is crucial in helping the practicing radiologist to achieve a more accurate diagnosis.

  19. Pitfalls in diagnostic radiology

    Energy Technology Data Exchange (ETDEWEB)

    Peh, Wilfred C.G. (ed.) [Khoo Teck Puat Hospital (Singapore). Dept. of Diagnostic Radiology

    2015-04-01

    Only textbook to focus primarily on the topic of pitfalls in diagnostic radiology. Highlights the pitfalls in a comprehensive and systematic manner. Written by experts in different imaging modalities and subspecialties from reputable centers across the world. The practice of diagnostic radiology has become increasingly complex, with the use of numerous imaging modalities and division into many subspecialty areas. It is becoming ever more difficult for subspecialist radiologists, general radiologists, and residents to keep up with the advances that are occurring year on year, and this is particularly true for less familiar topics. Failure to appreciate imaging pitfalls often leads to diagnostic error and misinterpretation, and potential medicolegal problems. Diagnostic errors may be due to various factors such as inadequate imaging technique, imaging artifacts, failure to recognize normal structures or variants, lack of correlation with clinical and other imaging findings, and poor training or inexperience. Many, if not most, of these factors are potentially recognizable, preventable, or correctable. This textbook, written by experts from reputable centers across the world, systematically and comprehensively highlights the pitfalls that may occur in diagnostic radiology. Both pitfalls specific to different modalities and techniques and those specific to particular organ systems are described with the help of numerous high-quality illustrations. Recognition of these pitfalls is crucial in helping the practicing radiologist to achieve a more accurate diagnosis.

  20. Development of in situ cleaning techniques for diagnostic mirrors in ITER

    International Nuclear Information System (INIS)

    Litnovsky, A.; Laengner, M.; Matveeva, M.; Schulz, Ch.; Marot, L.; Voitsenya, V.S.; Philipps, V.; Biel, W.; Samm, U.

    2011-01-01

    Mirrors will be used in all optical and laser-based diagnostic systems of ITER. In the severe environment, the optical characteristics of mirrors will be degraded, hampering the entire performance of the respective diagnostics. A minute impurity deposition of 20 nm of carbon on the mirror is sufficient to decrease the mirror reflectivity by tens of percent outlining the necessity of the mirror cleaning in ITER. The results of R and D on plasma cleaning of molybdenum diagnostic mirrors are reported. The mirrors contaminated with amorphous carbon films in the laboratory conditions and in the tokamaks were cleaned in steady-state hydrogenic plasmas. The maximum cleaning efficiency of 4.2 nm/min was reached for the laboratory and soft tokamak hydrocarbon films, whereas for the hard tokamak films the carbidization of mirrors drastically decreased the cleaning efficiency down to 0.016 nm/min. This implies the necessity of sputtering cleaning of contaminated mirrors as the only reliable tool to remove the deposits by plasma cleaning. An overview of R and D program on mirror cleaning is provided along with plans for further studies and the recommendations for ITER mirror-based diagnostics.

  1. Critical evaluation of fine needle aspiration cytology as a diagnostic technique in bone tumors and tumor-like lesions.

    Science.gov (United States)

    Chakrabarti, Sudipta; Datta, Alok Sobhan; Hira, Michael

    2012-01-01

    Though open surgical biopsy is the procedure of choice for the diagnosis of bone tumors, many disadvantages are associated with this approach. The present study was undertaken to evaluate the role of fine needle aspiration cytology (FNAC) as a diagnostic tool in cases of bony tumors and tumor-like lesions which may be conducted in centers where facilities for surgical biopsies are inadequate. The study population consisted of 51 cases presenting with a skeletal mass. After clinical evaluation, radiological correlation was done to assess the nature and extent of each lesion. Fine needle aspiration was performed aseptically and smears were prepared. Patients subsequently underwent open surgical biopsy and tissue samples were obtained for histopathological examination. Standard statistical methods were applied for analysis of data. Adequate material was not obtained even after repeated aspiration in seven cases, six of which were benign. Among the remaining 44 cases, diagnosis of malignancy was correctly provided in 28 (93.3%) out of 30 cases and categorical diagnosis in 20 (66.67%). Interpretation of cytology was more difficult in cases of benign and tumor-like lesions, with a categorical opinion only possible in seven (50%) cases. Statistical analysis showed FNAC with malignant tumors to have high sensitivity (93.3%), specificity (92.9%) and positive predictive value of 96.6%, whereas the negative predictive value was 86.7%. FNAC should be included in the diagnostic workup of a skeletal tumor because of its simplicity and reliability. However, a definitive pathologic diagnosis heavily depends on compatible clinical and radiologic features which can only be accomplished by teamwork. The cytological technique applied in this study could detect many bone tumors and tumor-like conditions and appears particularly suitable as a diagnostic technique for rural regions of India as other developing countries.

  2. Nanobiosensors in diagnostics

    Directory of Open Access Journals (Sweden)

    Alejandro Chamorro-Garcia

    2016-11-01

    Full Text Available Medical diagnosis has been greatly improved thanks to the development of new techniques capable of performing very sensitive detection and quantifying certain parameters. These parameters can be correlated with the presence of specific molecules and their quantity. Unfortunately, these techniques are demanding, expensive, and often complicated. On the other side, progress in other fields of science and technology has contributed to the rapid growth of nanotechnology. Although being an emerging discipline, nanotechnology has raised huge interest and expectations. Most of the enthusiasm comes from new possibilities and properties of nanomaterials. Biosensors (simple, robust, sensitive, cost-effective combined with nanomaterials, also called nanobiosensors, are serving as bridge between advanced detection/diagnostics and daily/routine tests. Here we review some of the latest applications of nanobiosensors in diagnostics field.

  3. Development of a neural network technique for KSTAR Thomson scattering diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Seung Hun, E-mail: leesh81@nfri.re.kr; Lee, J. H. [National Fusion Research Institute, 169-148 Gwahak-ro, Yuseong-gu, Daejeon 34133 (Korea, Republic of); Yamada, I. [National Institute Fusion Science, Toki, Gifu 509-5292 (Japan); Park, Jae Sun [Department of Physics, Korea Advanced Institute of Science and Technology, 291 Daehak-ro, Yuseong-gu, Daejeon 34141 (Korea, Republic of)

    2016-11-15

    Neural networks provide powerful approaches of dealing with nonlinear data and have been successfully applied to fusion plasma diagnostics and control systems. Controlling tokamak plasmas in real time is essential to measure the plasma parameters in situ. However, the χ{sup 2} method traditionally used in Thomson scattering diagnostics hampers real-time measurement due to the complexity of the calculations involved. In this study, we applied a neural network approach to Thomson scattering diagnostics in order to calculate the electron temperature, comparing the results to those obtained with the χ{sup 2} method. The best results were obtained for 10{sup 3} training cycles and eight nodes in the hidden layer. Our neural network approach shows good agreement with the χ{sup 2} method and performs the calculation twenty times faster.

  4. Diagnostic performance of state-of-the-art imaging techniques for morphological assessment of vascular abnormalities in patients with chronic thromboembolic pulmonary hypertension (CTEPH)

    Energy Technology Data Exchange (ETDEWEB)

    Ley, Sebastian [University Hospital Heidelberg, Department of Diagnostic and Interventional Radiology, Heidelberg (Germany); Ley-Zaporozhan, Julia [University Hospital Heidelberg, Department of Diagnostic and Interventional Radiology, Heidelberg (Germany); Johannes Gutenberg University, Department of Diagnostic and Interventional Radiology; Universitaetsmedizin, Mainz (Germany); Pitton, Michael B.; Schneider, Jens; Wirth, Gesine M.; Dueber, Christoph; Kreitner, Karl-Friedrich [Johannes Gutenberg University, Department of Diagnostic and Interventional Radiology; Universitaetsmedizin, Mainz (Germany); Mayer, Eckhard [Kerckhoff-Hospital Bad Nauheim, Department of Thoracic Surgery, Bad Nauheim (Germany)

    2012-03-15

    To determine the most comprehensive imaging technique for the assessment of pulmonary arteries in patients with chronic thromboembolic pulmonary hypertension (CTEPH). 24 patients with CTEPH were examined by ECG-gated multi-detector CT angiography (MD-CTA), contrast-enhanced MR angiography (ce-MRA) and selective digital subtraction angiography (DSA) within 3 days. Two readers in consensus separately evaluated each imaging technique (48 main, 144 lobar and 449 segmental arteries) for typical changes like complete obstructions, vessel cut-offs, intimal irregularities, incorporated thrombus formations, and bands and webs. A joint interpretation of all three techniques served as a reference standard. Based on image quality, there was no non-diagnostic examination by either imaging technique. DSA did not sufficiently display 1 main, 3 lobar and 4 segmental arteries. The pulmonary trunk was not assessable by DSA. One patient showed thrombotic material at this level only by MD-CTA and MRA. Sensitivity and specificity of MD-CTA regarding CTEPH-related changes at the main/lobar and at the segmental levels were 100%/100% and 100%/99%, of ce-MRA 83.1%/98.6% and 87.7%/98.1%, and of DSA 65.7%/100% and 75.8%/100%, respectively. ECG-gated MD-CTA proved the most adequate technique for assessment of the pulmonary arteries in the diagnostic work-up of CTEPH patients. (orig.)

  5. [Continuous funding of National Natural Science Foundation of China has boosted the development of the discipline of ophthalmology over the past 25 years].

    Science.gov (United States)

    Jia, Ren-bing; Fan, Xian-qun; Xu, Yan-ying; Dong, Er-dan

    2012-02-01

    To analyze the role of National Natural Science Foundation of China (NSFC) on the development of the discipline of Ophthalmology from 1986 to 2010. Data on the total number of projects and funding of NSFC allocated to Ophthalmology, as well as papers published, awards, personnel training, subject construction were collected, and the role of NSFC on other sources of funding was evaluated. From 1986 to 2010, NSFC supported a total of 593 scientific research projects of Ophthalmology, funding a total amount of 152.44 million Yuan, among which were 371 free application projects, 156 Young Scientist Funds, 9 Key Programs, 5 National Science Fund for Distinguished Young Scholars, 3 Major international (regional) joint research programs, 1 Science Fund for Creative Research Group and 48 other projects. Over the past 25 years, the number of NSFC projects received by Ophthalmology has been an overall upward trend in the share in the Department of Life (Health) Sciences. Take the projects (186 of 292, 63.7%) as examples completed between 2002 and 2010, a total 262 papers were published in Science Citation Index (SCI) included journals and 442 papers were published in Chinese journals. Meanwhile, 8 Second prizes of National Science and Technology Progress Award and 1 State Technological Invention Award were received. As of 2010, the training of a total of more than 40 postdoctoral, more than 400 doctoral students and more than 600 graduate students have been completed. 5 national key disciplines and 1 national key laboratory have been built. Moreover, 2 "973" programs from Ministry of Science and Technology and 1 project of special fund in the public interest from Ministry of Public Health were obtained. 2 scholars were among the list of Yangtze Fund Scholars granted by Ministry of Education. Over the past 25 years, a full range of continuous funding from NSFC has led to fruitful results and a strong impetus to the progress of discipline of Ophthalmology.

  6. Kinetic and Diagnostic Studies of Molecular Plasmas Using Laser Absorption Techniques

    International Nuclear Information System (INIS)

    Welzel, S; Rousseau, A; Davies, P B; Roepcke, J

    2007-01-01

    Within the last decade mid infrared absorption spectroscopy between 3 and 20 μm, known as Infrared Laser Absorption Spectroscopy (IRLAS) and based on tuneable semiconductor lasers, namely lead salt diode lasers, often called tuneable diode lasers (TDL), and quantum cascade lasers (QCL) has progressed considerably as a powerful diagnostic technique for in situ studies of the fundamental physics and chemistry of molecular plasmas. The increasing interest in processing plasmas containing hydrocarbons, fluorocarbons, organo-silicon and boron compounds has lead to further applications of IRLAS because most of these compounds and their decomposition products are infrared active. IRLAS provides a means of determining the absolute concentrations of the ground states of stable and transient molecular species, which is of particular importance for the investigation of reaction kinetics. Information about gas temperature and population densities can also be derived from IRLAS measurements. A variety of free radicals and molecular ions have been detected, especially using TDLs. Since plasmas with molecular feed gases are used in many applications such as thin film deposition, semiconductor processing, surface activation and cleaning, and materials and waste treatment, this has stimulated the adaptation of infrared spectroscopic techniques to industrial requirements. The recent development of QCLs offers an attractive new option for the monitoring and control of industrial plasma processes as well as for highly time-resolved studies on the kinetics of plasma processes. The aim of the present article is threefold: (i) to review recent achievements in our understanding of molecular phenomena in plasmas (ii) to report on selected studies of the spectroscopic properties and kinetic behaviour of radicals, and (iii) to describe the current status of advanced instrumentation for TDLAS in the mid infrared

  7. Development of an Accident Diagnostic Scheme Using Artificial Intelligence Techniques (I)

    Energy Technology Data Exchange (ETDEWEB)

    Na, M. G.; Lee, S. H.; Kim, D. S.; No, Y. G.; Lee, S. W. [Chosun University, Gwangju (Korea, Republic of); Ahn, K. I. [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2010-06-15

    As a means to effectively manage the severe nuclear accidents, it is important to identify and diagnose the accident initiating events during an initial short time interval after the accidents by observing the major controlling parameters. Main objective of this study is to develop the diagnostic approach for the accurate prediction of accident initiating events using artificial intelligence techniques. For this, first, a variety of artificial intelligence techniques such as Finn, Gmbh, and Sm were examined through this study. Among them, Sc and Gmbh model were assessed as a useful approach to predict the break location and the break size of Local. In order to verify the proposed algorithm, the 111 accident simulation data (based on Map) were applied to train the Sc and Gmbh models, and the test data was used to independently verify whether or not the SVC and GMDH models work well. The analysis of the maximum errors and RMS errors, and the performance of the GMDH according to the existence of measurement errors and SIS actuation showed that the proposed SVC and GMDH models can accurately classify the break locations and accurately predict the break size. As the time-integrated signals were used for inputs into the GMDH model within a period of 60 second after a reactor scram, the actuation of the safety systems such as safety injection system (SIS), auxiliary feed water system, and containment spray system, were not considered in this study. It is because the initial 60 second time-integrated signals were used and the safety systems usually start to actuate after a more than 60 second time delay after the reactor scram

  8. Development of an Accident Diagnostic Scheme Using Artificial Intelligence Techniques (I)

    International Nuclear Information System (INIS)

    Na, M. G.; Lee, S. H.; Kim, D. S.; No, Y. G.; Lee, S. W.; Ahn, K. I.

    2010-06-01

    As a means to effectively manage the severe nuclear accidents, it is important to identify and diagnose the accident initiating events during an initial short time interval after the accidents by observing the major controlling parameters. Main objective of this study is to develop the diagnostic approach for the accurate prediction of accident initiating events using artificial intelligence techniques. For this, first, a variety of artificial intelligence techniques such as Finn, Gmbh, and Sm were examined through this study. Among them, Sc and Gmbh model were assessed as a useful approach to predict the break location and the break size of Local. In order to verify the proposed algorithm, the 111 accident simulation data (based on Map) were applied to train the Sc and Gmbh models, and the test data was used to independently verify whether or not the SVC and GMDH models work well. The analysis of the maximum errors and RMS errors, and the performance of the GMDH according to the existence of measurement errors and SIS actuation showed that the proposed SVC and GMDH models can accurately classify the break locations and accurately predict the break size. As the time-integrated signals were used for inputs into the GMDH model within a period of 60 second after a reactor scram, the actuation of the safety systems such as safety injection system (SIS), auxiliary feed water system, and containment spray system, were not considered in this study. It is because the initial 60 second time-integrated signals were used and the safety systems usually start to actuate after a more than 60 second time delay after the reactor scram

  9. Additive diagnostic role of imaging in glaucoma: optical coherence tomography and retinal nerve fiber layer photography.

    Science.gov (United States)

    Kim, Ko Eun; Kim, Seok Hwan; Oh, Sohee; Jeoung, Jin Wook; Suh, Min Hee; Seo, Je Hyun; Kim, Martha; Park, Ki Ho; Kim, Dong Myung

    2014-11-20

    To investigate the additive diagnostic role of spectral-domain optical coherence tomography (SD-OCT) and red-free retinal nerve fiber layer photography (RNFLP) in making clinical glaucoma diagnosis. Four diagnostic combination sets, including the most recent image from each measurement of 196 glaucoma eyes (including the 44 preperimetric glaucoma eyes) and 101 healthy eyes, were prepared: (1) stereo disc photography and Humphrey visual field (SH), (2) SH and SD-OCT (SHO), (3) SH and RNFLP (SHR), and (4) SHR and SD-OCT (SHRO). Each randomly sorted set was serially presented at 1-month intervals to five glaucoma specialists who were asked to evaluate them in a subjective and independent manner. The specialists' glaucoma-diagnostic performances based on the sets were then compared. For each specialist, adding SD-OCT to SH or SHR increased the glaucoma-diagnostic sensitivity but not to a level of statistical significance. For one specialist, adding RNFLP to SH significantly increased the sensitivity. Each specialist showed a high level of specificity regardless of the diagnostic set. The overall sensitivity of all specialists' assessments was significantly increased by adding RNFLP or the combination of SD-OCT and RNFLP to SH (P < 0.001); however, adding SD-OCT to SH or SHR did not significantly increase the sensitivity. A similar relationship was noted also for the preperimetric glaucoma subgroup. In contrast to RNFLP, SD-OCT did not significantly enhance the diagnostic accuracy of detecting glaucoma or even of preperimetric glaucoma. Our results suggest that, at least for glaucoma specialists, the additive diagnostic role of OCT is limited. Copyright 2014 The Association for Research in Vision and Ophthalmology, Inc.

  10. Diagnostic imaging of shoulder impingement

    International Nuclear Information System (INIS)

    Merl, T.; Weinhardt, H.; Oettl, G.; Lenz, M.; Riel, K.A.

    1996-01-01

    Magnetic resonance imaging is a method that has been advancing in the last few years to the modality of choice for diagnostic evaluation of the bone joints, as the method is capable of imaging not only the ossous but also the soft tissue components of the joint. MRI likewise has become an accepted method for diagnostic evaluation of syndromes of the shoulder, with high diagnostic accuracy in detecting rotator cuff lesions, or as an efficient MRI arthrography for evaluation of the instability or lesions of the labrocapsular complex. In the evaluation of early stages of shoulder impingement, the conventional MRI technique as a static technique yields indirect signs which in many cases do not provide the diagnostic certainty required in order to do justice to the functional nature of the syndrome. In these cases, functional MRI for imaging of the arm in abducted position and in rotational movement may offer a chance to early detect impingement and thus identify patients who will profit from treatment at an early stage [de

  11. Epidemiology of intestinal parasitosis in Italy between 2005 and 2008: diagnostic techniques and methodologies

    Directory of Open Access Journals (Sweden)

    Daniele Crotti

    2013-04-01

    Full Text Available Aim of the study was to keep a real and actual photo relating to 2005-2008 regarding to diagnostic techniques and methodologies for intestinal parasites; so it would be possible to know specific epidemiology and suggest more rational and efficacious guide-lines. All members of AMCLI were involved in the proposal of a retrospective study regarding bowel parasites, helminths and protozoa.To engaged laboratories we asked how O&P was performed, if a specifical research for E. vermicularis and S. stercoralis was performed, if for the identification of D. fragilis, Entamoeba histolytica/dispar and Cryptosporidum spp were performed recommended specific permanent stains. 23 laboratories gave assent; but for an inferior number was possible to use the data for analysis and evaluation. Relating O&P only some laboratories performed permanent stains: Giemsa for D. fragilis, antigen and/or Trichrome stain for E. histolytica/dispar, antigen and/or acid fast stain for Cryptosporidium spp.Not all laboratories research specifically S. stercoralis. So the epidemiology is differentiated and related more to adequate or not adequate techniques than cohorts of examined populations. The overall positivity for parasites ranged from 0% to18.7%,for protozoa (pathogens or not were from 0% to 14.7%; for nematodes from 0% to 3.7%; for cestodes from 0% to 1.0%; for trematodes from 0% to 1.0%.Among helminths, E. vermicularis, followed by S. stercoralis, also in O&P, is the most frequent.The specific research of S. stercoralis gave a positivity from 0% to 33.3%; the cellophane tape test was positive for E. vermicularis from 0% fo 21.9% of cases.Among pathogen protozoa, D. fragilis, when permanent stain were applied, prevailed from 0% to 16.6%; G. duodenalis from 0.8% to 4.3%; E. histolytica/dispar, using a permanent stain or research of antigen, was identified from 0% to 20.6%. Coccidia were very rare, with Cryptosporidium spp observed from 0% to 5.2%. These are our conclusions

  12. Optical diagnostics of intermittent flows

    DEFF Research Database (Denmark)

    Okulov, V.L.; Naumov, I.V.; Sørensen, Jens Nørkær

    2007-01-01

    The efficiency of combined use of different optical techniques for flow diagnostics is demonstrated with the practically important case of intense swirling flows. It is shown that, when applied separately, commonly used optical measuring techniques, such as laser Doppler anemometry and particle...... is for the first time applied for diagnostics of the flow pattern in a closed cylinder with a rotating end face with the aim of studying the changeover from the steady axisymmetric to unsteady asymmetric flow over a wide range of flow parameters. It is found that such a transition is notable for azimuthal...

  13. [Ophthalmological opinions for liability affairs material damage (Part I) (author's transl)].

    Science.gov (United States)

    Burggraf, H

    1979-02-01

    German law abides anyone reponsible for the damage he or she has caused to another person's property or corporal integrity. This includes all medical costs directed towards the restitution of health as well as economical damage in direct consequence of the corporal damage. An ophthalmological expert is to state his opinion therefore in accordance with the specific conditions of every individual case and not just according to general charts. Financial compensation is only granted for the actual results of damage inquestion. Prior damage and disability have to be remarked but not to justify a financial compensation. The question of smart-money is dealt with in Part II.

  14. Reliability of diagnostic imaging techniques in suspected acute appendicitis: proposed diagnostic protocol; Indicacion de las tecnicas de diagnostico por la imagen en la sospecha de apendicitis aguda: propuesta de protocolo diagnostico

    Energy Technology Data Exchange (ETDEWEB)

    Cura del, J. L.; Oleaga, L.; Grande, D.; Vela, A. C.; Ibanez, A. M. [Hospital de Basureto. Bilbao (Spain)

    2001-07-01

    To study the utility of ultrasound and computed tomography (CT) in case of suspected appendicitis. To determine the diagnostic yield in terms of different clinical contexts and patient characteristics. to assess the costs and benefits of introducing these techniques and propose a protocol for their use. Negative appendectomies, complications and length of hospital stay in a group of 152 patients with suspected appendicitis who underwent ultrasound and CT were compared with those of 180 patients who underwent appendectomy during the same time period, but had not been selected for the first group: these patients costs for each group were calculated. In the first group, the diagnostic value of the clinical signs was also evaluated. The reliability of the clinical signs was limited, while the results with ultrasound and CT were excellent. The incidence of negative appendectomy was 9.6% in the study group and 12.2% in the control group. Moreover, there were fewer complications and a shorter hospital stay in the first group. Among men, however, the rate of negative appendectomy was lower in the control group. The cost of using ultrasound and CT in the management of appendicitis was only slightly higher than that of the control group. Although ultrasound and CT are not necessary in cases in which the probability of appendicitis is low or in men presenting clear clinical evidence, the use of these techniques is indicated in the remaining cases in which appendicitis is suspected. In children, ultrasound is the technique of choice. In all other patients, if negative results are obtained with one of the two techniques, the other should be performed. (Author) 49 refs.

  15. Quality of life in chemical warfare survivors with ophthalmologic injuries: the first results form Iran Chemical Warfare Victims Health Assessment Study

    Directory of Open Access Journals (Sweden)

    Soroush Mohammad

    2009-01-01

    Full Text Available Abstract Background Iraq used chemical weapons extensively against the Iranians during the Iran-Iraq war (1980–1988. The aim of this study was to assess the health related quality of life (HRQOL in people who had ophthalmologic complications due to the sulfur mustard gas exposure during the war. Methods The Veterans and Martyrs Affair Foundation (VMAF database indicated that there were 196 patients with severe ophthalmologic complications due to chemical weapons exposure. Of these, those who gave consent (n = 147 entered into the study. Quality of life was measured using the 36-item Short Form Health Survey (SF-36 and scores were compared to those of the general public. In addition logistic regression analysis was performed to indicate variables that contribute to physical and mental health related quality of life. Results The mean age of the patients was 44.8 (SD = 8.7 ranging from 21 to 75 years. About one-third of the cases (n= 50 reported exposure to chemical weapons more than once. The mean exposure duration to sulfur mustard gas was 21.6 years (SD = 1.2. The lowest scores on the SF-36 subscales were found to be: the role physical and the general health. Quality of life in chemical warfare victims who had ophthalmologic problems was significantly lower than the general public (P Conclusion The study findings suggest that chemical warfare victims with ophthalmologic complications suffer from poor health related quality of life. It seems that the need for provision of health and support for this population is urgent. In addition, further research is necessary to measure health related quality of life in victims with different types of disabilities in order to support and enhance quality of life among this population.

  16. Diagnostics for environmental aspects of pulsed atmospheric discharges

    International Nuclear Information System (INIS)

    Rutgers, W.R.; Veldhuizen, E.M. van

    2001-01-01

    Diagnostics for the study of pulsed atmospheric discharges are discussed. To obtain parameters for describing conversion processes of pollutants into harmless products many diagnostic techniques are in use and under development. In this contribution electrical, optical and chemical diagnostics used in air and wastewater remediation are reviewed

  17. Diagnostics for environmental aspects of pulsed atmospheric discharges

    Energy Technology Data Exchange (ETDEWEB)

    Rutgers, W.R.; Veldhuizen, E.M. van [Eindhoven Univ. of Technology (Netherlands). Dept. of Applied Physics

    2001-07-01

    Diagnostics for the study of pulsed atmospheric discharges are discussed. To obtain parameters for describing conversion processes of pollutants into harmless products many diagnostic techniques are in use and under development. In this contribution electrical, optical and chemical diagnostics used in air and wastewater remediation are reviewed.

  18. A hybrid body technique: does the pulse diagnostic cun guan chi method have Chinese-Tibetan origins?

    Science.gov (United States)

    Hsu, Elisabeth

    2008-01-01

    This article investigates the medieval origins of the main pulse diagnostic method in contemporary Chinese medicine, sometimes known as san bu (three sectors) method, which requires physicians to examine the mai (vessels, vessel movements or pulse) on the wrist at the three locations cun guan chi (inch, gate, foot). The article provides evidence to suggest that this body technique grew out of an earlier Chinese one, the cun chi (inch-foot) method, which appears to have aimed at investigating the qualities of yin and yang in order to determine the condition of a patient by means of exploring fairly large areas of the patient's body surface with the palms. The article furthermore posits that the cun chi method was decisively transformed in medieval times, presumably due to the impact of early Tibetan pulse diagnostic practices: it became framed in a numerology of three and started advocating the use of the fingertips for sensing the pulse beats. The article, which draws on detailed textual analyses of medieval manuscripts, on visual evidence and also on psychophysical research, furthermore highlights how misunderstandings can constructively contribute to cultural communication.

  19. THE TECHNIQUE OF DIAGNOSTICS OF THE PRODUCTION CAPACITY OF THE ORGANIZATION

    Directory of Open Access Journals (Sweden)

    E. S. Popova

    2014-01-01

    Full Text Available In the article due to the need for diagnostics of the production capacity of the organization. Formed methodological framework for evaluating the production potential of the organization. Research capacity will also enable the organization to timely respond to current changes. A classification of types of diagnostics of the production capacity of the organization according to the following criteria: timing, goals, content, purpose results. The article discusses the economic and organizational diagnosis of the production capacity of the organization. Economic diagnosis is based on the calculation of indicators of use of resources of the organization. Organizational diagnosis assesses the security of the organization's activities. Diagnosis productive capacity is the basis for improvement of the organization's activities. Defined diagnostics of the production capacity of the organization. Justified the selection stages of the research production potential. The first stage is the preliminary diagnosis. The second stage provides for the rapid diagnosis of production potential. At the third stage it is advisable to perform problem diagnosis. Problem diagnosis consists of economic and organizational diagnosis. Economic diagnosis assesses the state of the elements of the production potential of the organization. Organizational diagnostics analyses provide productive capacity. The fourth stage is represented by the solution of the problems of utilization of production capacity. Each stage is considered, has its content and specific diagnostic methods of production potential. This method allows determining the state of the elements, the efficiency of utilization of production capacity. The estimation of the production potential is based on the application of utility theory. This assessment provides a definition of the criteria and the scale of usefulness. This will allow you to measure the production potential numerically. In the end, it is revealed

  20. An Interactive Method for Teaching Anatomy of the Human Eye for Medical Students in Ophthalmology Clinical Rotations

    Science.gov (United States)

    Kivell, Tracy L.; Doyle, Sara K.; Madden, Richard H.; Mitchell, Terry L.; Sims, Ershela L.

    2009-01-01

    Much research has shown the benefits of additional anatomical learning and dissection beyond the first year of medical school human gross anatomy, all the way through postgraduate medical training. We have developed an interactive method for teaching eye and orbit anatomy to medical students in their ophthalmology rotation at Duke University…

  1. Diagnostic development

    International Nuclear Information System (INIS)

    Barnett, C.F.; Brisson, D.A.; Greco, S.E.

    1978-01-01

    During the past year the far-infrared or submillimeter diagnostic research program resulted in three major developments: (1) an optically pumped 0.385-μm D 2 O-laser oscillator-amplifier system was operated at a power level of 1 MW with a line width of less than 50 MHz; (2) a conical Pyrex submillimeter laser beam dump with a retention efficiency greater than 10 4 was developed for the ion temperature Thompson scattering experiment; and (3) a new diagnostic technique was developed that makes use of the Faraday rotation of a modulated submillimeter laser beam to determine plasma current profile. Measurements of the asymmetric distortion of the H/sub α/ (6563 A) spectral line profile show that the effective toroidal drift velocity, dv/sub two vertical bars i/dT/sub i/, may be used as an indicator of plasma quality and as a complement to other ion temperature diagnostics

  2. Flowfield modeling and diagnostics

    International Nuclear Information System (INIS)

    Gupta, A.K.; Lilley, D.G.

    1985-01-01

    This textbook is devoted solely to flowfield modeling and diagnostics; their practical use, recent and current research, and projected developments and trends. It provides an account of the use of a broad range of techniques in industrial and research practice, both with and without combustion. Application ideas are complemented by details about experimental and modeling techniques

  3. [A comprehensive approach to designing of magnetotherapy techniques based on the Atos device].

    Science.gov (United States)

    Raĭgorodskiĭ, Iu M; Semiachkin, G P; Tatarenko, D A

    1995-01-01

    The paper determines how to apply a comprehensive approach to designing magnetic therapeutical techniques based on concomitant exposures to two or more physical factors. It shows the advantages of the running pattern of a magnetic field and photostimuli in terms of optimization of physiotherapeutical exposures. An Atos apparatus with an Amblio-1 attachment is used as an example to demonstrate how to apply the comprehensive approach for ophthalmology.

  4. Orange fiber laser for ophthalmology

    Science.gov (United States)

    Adachi, M.; Kojima, K.; Hayashi, K.

    2007-02-01

    For the light source of photocoagulators for ophthalmology, orange laser is more suitable than green laser because of low scattering loss by the crystalline lens, and low absorption by xanthophylls in the retina. We developed two orange fiber lasers (580 nm and 590 nm) to investigate the effect depending on the difference in the range of orange. The 580nm laser is composed of a 1160 nm fiber laser and a Periodically Polled Lithium Niobate (PPLN) crystal for second harmonic generation. The 1160 nm fiber laser beam is focused into the MgO-doped PPLN crystal whose length is 30 mm with 3-pass configuration. Continuous-wave 1.3 W output power of 580 nm was obtained with 5.8 W input power of 1160nm for the first time. The conversion efficiency was 22%. The band width of the second harmonic was 0.006 nm (FWHM). The 590 nm laser is almost the same as 580 nm laser source. In this case we used a Raman shift fiber to generate 1180 nm, and the output power of 590 nm was 1.4 W. We developed an evaluation model of photocoagulator system using these two laser sources. A 700 mW coagulation output power was obtained with this orange fiber laser photocoagulator system. This is enough power for the eye surgery. We have the prospect of the maintenance-free, long-life system that is completely air-cooled. We are planning to evaluate this photocoagulator system in order to investigate the difference between the two wavelengths at the field test.

  5. Gonad shielding in diagnostic radiology

    International Nuclear Information System (INIS)

    Anon.

    1975-01-01

    The use of gonad shielding is an important radiation protection technique, intended to reduce unnecessary x-ray exposure of the gonads of patients from diagnostic x-ray procedures. The types of gonad shields in use are discussed as are the types of diagnostic examinations that should include gonad shielding. It was found that when properly used, most shields provided substantial gonad dose reductions

  6. Tunable diode laser spectroscopy as a technique for combustion diagnostics

    International Nuclear Information System (INIS)

    Bolshov, M.A.; Kuritsyn, Yu.A.; Romanovskii, Yu.V.

    2015-01-01

    Tunable diode laser absorption spectroscopy (TDLAS) has become a proven method of rapid gas diagnostics. In the present review an overview of the state of the art of TDL-based sensors and their applications for measurements of temperature, pressure, and species concentrations of gas components in harsh environments is given. In particular, the contemporary tunable diode laser systems, various methods of absorption detection (direct absorption measurements, wavelength modulation based phase sensitive detection), and relevant algorithms for data processing that improve accuracy and accelerate the diagnostics cycle are discussed in detail. The paper demonstrates how the recent developments of these methods and algorithms made it possible to extend the functionality of TDLAS in the tomographic imaging of combustion processes. Some prominent examples of applications of TDL-based sensors in a wide range of practical combustion aggregates, including scramjet engines and facilities, internal combustion engines, pulse detonation combustors, and coal gasifiers, are given in the final part of the review. - Highlights: • Overview of modern TDL-based sensors for combustion • TDL systems, methods of absorption detection and algorithms of data processing • Prominent examples of TDLAS diagnostics of the combustion facilities • Extension of the TDLAS on the tomographic imaging of combustion processes

  7. Noninvasive Remote Sensing Techniques for Infrastructures Diagnostics

    Directory of Open Access Journals (Sweden)

    Angelo Palombo

    2011-01-01

    Full Text Available The present paper aims at analyzing the potentialities of noninvasive remote sensing techniques used for detecting the conservation status of infrastructures. The applied remote sensing techniques are ground-based microwave radar interferometer and InfraRed Thermography (IRT to study a particular structure planned and made in the framework of the ISTIMES project (funded by the European Commission in the frame of a joint Call “ICT and Security” of the Seventh Framework Programme. To exploit the effectiveness of the high-resolution remote sensing techniques applied we will use the high-frequency thermal camera to measure the structures oscillations by high-frequency analysis and ground-based microwave radar interferometer to measure the dynamic displacement of several points belonging to a large structure. The paper describes the preliminary research results and discusses on the future applicability and techniques developments for integrating high-frequency time series data of the thermal imagery and ground-based microwave radar interferometer data.

  8. Instrumentation for localized superconducting cavity diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Conway, Z. A. [Argonne National Lab. (ANL), Argonne, IL (United States). Physics Division; Ge, M. [Cornell Lab. for Accelerator-Based Sciences and Education, Ithaca, NY (United States); Iwashita, Y. [Kyoto Univ. (Japan)

    2017-01-12

    Superconducting accelerator cavities are now routinely operated at levels approaching the theoretical limit of niobium. To achieve these operating levels more information than is available from the RF excitation signal is required to characterize and determine fixes for the sources of performance limitations. This information is obtained using diagnostic techniques which complement the analysis of the RF signal. In this paper we describe the operation and select results from three of these diagnostic techniques: the use of large scale thermometer arrays, second sound wave defect location and high precision cavity imaging with the Kyoto camera.

  9. Time-resolved x-ray diagnostics

    International Nuclear Information System (INIS)

    Lyons, P.B.

    1981-01-01

    Techniques for time-resolved x-ray diagnostics will be reviewed with emphasis on systems utilizing x-ray diodes or scintillators. System design concerns for high-bandwidth (> 1 GHz) diagnostics will be emphasized. The limitations of a coaxial cable system and a technique for equalizing to improve bandwidth of such a system will be reviewed. Characteristics of new multi-GHz amplifiers will be presented. An example of a complete operational system on the Los Alamos Helios laser will be presented which has a bandwidth near 3 GHz over 38 m of coax. The system includes the cable, an amplifier, an oscilloscope, and a digital camera readout

  10. Data needs for diagnostics of low pressure plasmas

    International Nuclear Information System (INIS)

    Graham, Bill

    2000-01-01

    The low pressure plasma processing environment is complex and presents many diagnostic challenges. Here the diagnostic techniques used for accurate and detailed measurement of the density and energy distributions of charged and neutral species are reviewed. Most of the techniques rely heavily on atomic and molecular data. The specific data needs of each diagnostic are outlined. It is shown that in total these data needs are vast and diverse and cannot all be met from specific measurements or calculations. The real need is for generic scaling rules for each of the significant atomic and molecular processes

  11. The polaroid suppression test in a pediatric population with ophthalmologic disorders.

    Science.gov (United States)

    Pott, Jan Willem R; Kingma, C; Verhoeff, K; Grootendorst, R J; de Faber, J T H N

    2003-04-01

    The Polaroid suppression test (PST) is a new method for early detection of amblyogenic factors by screening for suppression. The apparatus can elicit suppression with the use of Polaroid filters. The aim of the present study was to examine a population of children with known ophthalmologic disorders using the PST to determine the rate of false-negative results of the PST. Six hundred four children, varying in age between 3 and 15 years (mean, 7.9) were examined using the PST. Ophthalmologic disorders ranged from strabismus and amblyopia to refractive disorders. Mean testing time for the PST was 43 seconds. The PST could not be administered to 34 children (5.6%); 443 children (73.3%) had abnormal results; and 127 children (22.2%) showed no suppression. The suppression in constant strabismus was detected in almost all cases. The sensitivity for accommodative forms of strabismus was lower, but amblyopia was never missed in these cases. In children with normal eye alignment, only 2.7% with an interocular acuity difference of more than 0.1 logMAR had no suppression. Of all 119 children with clinical defined amblyopia, only 1 (0.8%) did not have suppression. Overall sensitivity of the PST for strabismus and/or abnormal interocular acuity difference was 96.2% and specificity was 41.1%. The PST has great potential as a visual screening tool in young children. Only few children with amblyogenic factors were missed. Thus, the test can differentiate those children at risk for amblyopia from normally sighted children. Because specificity is lower, all children showing suppression with the PST in a screening situation should have further examination by the health care worker before being referred to the ophthalmologist.

  12. [Deep learning and neuronal networks in ophthalmology : Applications in the field of optical coherence tomography].

    Science.gov (United States)

    Treder, M; Eter, N

    2018-04-19

    Deep learning is increasingly becoming the focus of various imaging methods in medicine. Due to the large number of different imaging modalities, ophthalmology is particularly suitable for this field of application. This article gives a general overview on the topic of deep learning and its current applications in the field of optical coherence tomography. For the benefit of the reader it focuses on the clinical rather than the technical aspects.

  13. Update in Current Diagnostics and Therapeutics of Dry Eye Disease.

    Science.gov (United States)

    Thulasi, Praneetha; Djalilian, Ali Reza

    2017-11-01

    Dry eye disease (DED) represents a heterogeneous group of conditions with tear film insufficiency and signs and/or symptoms of ocular surface irritation. The clinical manifestations of DED can be highly variable; hence the diagnosis is often based on a combination of symptoms, signs, and clinical tests, given that any one of these alone would miss a significant number of patients. Similarly, the treatment must often be tailored to each patient by targeting the specific mechanisms involved in his or her disease. The purpose of this review is to summarize recent advances that have allowed us to better recognize, categorize, and treat patients with DED. The most notable new diagnostic tests in DED are tear film osmolarity, inflammatory biomarkers, and meibomian gland imaging. Therapeutically, anti-inflammatory therapy, meibomian gland heating and expression, and scleral contact lenses are some of the latest options available for treating DED. Copyright © 2017 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  14. Mammography: Technique and diagnostic accuracy

    International Nuclear Information System (INIS)

    Kim, Chung Ja; Bahk, Yong Whee; Lee, Don Young

    1974-01-01

    Mammography is now in world wide use, But this has received rather scanty attention in Korea. The purposes of the present communication are twofold: (1) Detailing of technical and photographic aspects of mam in ography and (2) an assessment of its diagnostic accuracy as experienced by us. The clinical materials consisted of 88 cases of mammography performed at the Department of Radiology, St. Mary's Hospital, Catholic Medical College during the 2 years-period from April 1972. We used nonscreen type mammographic or industrial fine- grain films, and a special mammographic device that can be attached to any of the ordinary radiographic machine. Technical factors are shown in Table II. Of 88 cases 19 were operated on or biopsied. There were 7 cases of carcinoma. 8 cases of inflammatory diseases, and 4 cases of benign tumor. Mammographic diagnosis was correct in 85.7% of carcinoma and 87.5% of inflammatory diseases. One misdiagnosis of 7 cases of carcinoma was turned out to be cystosarcoma phylloides. Of 4 cases of benign tumors 2 were correctly diagnosed, and the other 2 mistaken for either inflammatory disease or simple lactating breast. However, none of the benign conditions were diagnosed as malignant process. We found that nonscreen type mammographic or industrial fine-grain films, and hand-processing were necessary in obtaining the mammograms of desirable quality

  15. Microfluidic technology for molecular diagnostics.

    Science.gov (United States)

    Robinson, Tom; Dittrich, Petra S

    2013-01-01

    Molecular diagnostics have helped to improve the lives of millions of patients worldwide by allowing clinicians to diagnose patients earlier as well as providing better ongoing therapies. Point-of-care (POC) testing can bring these laboratory-based techniques to the patient in a home setting or to remote settings in the developing world. However, despite substantial progress in the field, there still remain many challenges. Progress in molecular diagnostics has benefitted greatly from microfluidic technology. This chapter aims to summarise the more recent advances in microfluidic-based molecular diagnostics. Sections include an introduction to microfluidic technology, the challenges of molecular diagnostics, how microfluidic advances are working to solve these issues, some alternative design approaches, and detection within these systems.

  16. Electron Bunch Length Diagnostic With Coherent Smith-Purcell Radiation

    Energy Technology Data Exchange (ETDEWEB)

    Nguyen, D.C.

    1997-05-12

    The authors have designed a new technique for measuring subpicosecond electron bunch lengths using coherent Smith-Purcell radiation. This new diagnostic technique involves passing the electron beam in close proximity of a grating with a period comparable to the electron bunch length. The emitted Smith-Purcell radiation will have a coherent component whose angular position and distribution are directly related to the electron bunch length and longitudinal profile, respectively. This new diagnostic technique is inherently simple, inexpensive and non-intercepting. The authors show that the new technique is also scaleable to femtosecond regime.

  17. Electron Bunch Length Diagnostic With Coherent Smith-Purcell Radiation

    International Nuclear Information System (INIS)

    Nguyen, D.C.

    1997-01-01

    The authors have designed a new technique for measuring subpicosecond electron bunch lengths using coherent Smith-Purcell radiation. This new diagnostic technique involves passing the electron beam in close proximity of a grating with a period comparable to the electron bunch length. The emitted Smith-Purcell radiation will have a coherent component whose angular position and distribution are directly related to the electron bunch length and longitudinal profile, respectively. This new diagnostic technique is inherently simple, inexpensive and non-intercepting. The authors show that the new technique is also scaleable to femtosecond regime

  18. Plasma Diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Zaveryaev, V [Kurchatov Institute, Moscow (Russian Federation); others, and

    2012-09-15

    The success in achieving peaceful fusion power depends on the ability to control a high temperature plasma, which is an object with unique properties, possibly the most complicated object created by humans. Over years of fusion research a new branch of science has been created, namely plasma diagnostics, which involves knowledge of almost all fields of physics, from electromagnetism to nuclear physics, and up-to-date progress in engineering and technology (materials, electronics, mathematical methods of data treatment). Historically, work on controlled fusion started with pulsed systems and accordingly the methods of plasma parameter measurement were first developed for short lived and dense plasmas. Magnetically confined hot plasmas require the creation of special experimental techniques for diagnostics. The diagnostic set is the most scientifically intensive part of a plasma device. During many years of research operation some scientific tasks have been solved while new ones arose. New tasks often require significant changes in the diagnostic system, which is thus a very flexible part of plasma machines. Diagnostic systems are designed to solve several tasks. As an example here are the diagnostic tasks for the International Thermonuclear Experimental Reactor - ITER: (1) Measurements for machine protection and basic control; (2) Measurements for advanced control; (3) Additional measurements for performance evaluation and physics. Every new plasma machine is a further step along the path to the main goal - controlled fusion - and nobody knows in advance what new phenomena will be met on the way. So in the planning of diagnostic construction we should keep in mind further system upgrading to meet possible new scientific and technical challenges. (author)

  19. Diagnostic double guarded low-volume uterine lavage in mares

    DEFF Research Database (Denmark)

    Christoffersen, Mette; Brandis, Louise; Samuelsson, Julia

    2014-01-01

    Endometritis constitutes a major problem in the management of broodmares; hence diagnostic tests with a high sensitivity and specificity are desired. We hypothesize that a double guarded uterine flush technique for bacterial culture and cytology is comparable to standard diagnostic tests, the end......Endometritis constitutes a major problem in the management of broodmares; hence diagnostic tests with a high sensitivity and specificity are desired. We hypothesize that a double guarded uterine flush technique for bacterial culture and cytology is comparable to standard diagnostic tests...... (lavage: 11%, swab: 8%, biopsy: 7%) (positive bacterial growth > 4 Colony forming units (CFU)). Positive cytology was less likely to occur when E. coli was isolated from the diagnostic tests compared to the growth of β-hemolytic streptococci. Isolation of pathogens from uterine samples was highly...

  20. Improving the Teaching Skills of Residents in a Surgical Training Program: Results of the Pilot Year of a Curricular Initiative in an Ophthalmology Residency Program.

    Science.gov (United States)

    Chee, Yewlin E; Newman, Lori R; Loewenstein, John I; Kloek, Carolyn E

    2015-01-01

    To design and implement a teaching skills curriculum that addressed the needs of an ophthalmology residency training program, to assess the effect of the curriculum, and to present important lessons learned. A teaching skills curriculum was designed for the Harvard Medical School (HMS) Residency Training Program in Ophthalmology. Results of a needs assessment survey were used to guide curriculum objectives. Overall, 3 teaching workshops were conducted between October 2012 and March 2013 that addressed areas of need, including procedural teaching. A postcurriculum survey was used to assess the effect of the curriculum. Massachusetts Eye and Ear Infirmary, a tertiary care institution in Boston, MA. Overall, 24 residents in the HMS Residency Training Program in Ophthalmology were included. The needs assessment survey demonstrated that although most residents anticipated that teaching would be important in their future career, only one-third had prior formal training in teaching. All residents reported they found the teaching workshops to be either very or extremely useful. All residents reported they would like further training in teaching, with most residents requesting additional training in best procedural teaching practices for future sessions. The pilot year of the resident-as-teacher curriculum for the HMS Residency Training Program in Ophthalmology demonstrated a need for this curriculum and was perceived as beneficial by the residents, who reported increased comfort in their teaching skills after attending the workshops. Copyright © 2015 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.

  1. Noise diagnostic: An advanced technique in Cuba

    International Nuclear Information System (INIS)

    Aguilar, O.

    1992-01-01

    This paper examines the main steps of the noise analysis technique implementation in our country from 1988. The review identifies two main areas, improvements of Nuclear Power Plant operational surveillance techniques and non-nuclear industrial applications. Also reported are some of the on going researches programs including projects on noise analysis instrumentation developments at the Higher Institute for Nuclear Sciences and Technology

  2. Evaluation of eLearning for the teaching of undergraduate ophthalmology at medical school: a randomised controlled crossover study.

    Science.gov (United States)

    Petrarca, Caroline A; Warner, Julia; Simpson, Andrew; Petrarca, Robert; Douiri, Abdel; Byrne, David; Jackson, Timothy L

    2018-05-25

    To compare ophthalmology teaching delivered by eLearning with traditional lectures, in terms of undergraduate performance and satisfaction. Randomised controlled crossover study at King's College London Medical School with 245 third year medical students. The ophthalmology syllabus was divided into ten topics. Five topics were randomised to be taught by traditional lectures and five by electronic learning (eLearning). For the second rotation of students the topics were crossed over, so that those topics taught by traditional lectures were taught by eLearning and vice versa. At the end of each rotation the students sat an optional online mock examination containing 100 questions (ten on each topic). Students' examination performance was compared between the two teaching methods. Student satisfaction was assessed using an online satisfaction survey. Outcome measures were the mean percentage of correct answers across all ten topics, student satisfaction and self-assessed knowledge. The mean examination score for questions taught by eLearning was 58% (95% CI, 55.7-59.6), versus 55% (95% CI 53.1-56.8) for traditional lectures (P = 0.047). Across all topics students were more satisfied with eLearning than traditional lectures, with 87% (95% CI 84.5-88.4) rating eLearning as 'excellent' or 'good' versus 65% (95% CI 62.0-67.4) for lectures (p eLearning compared to traditional lectures, with 166 (69.7%) rating eLearning 'much better' or 'better,' 61 (25.6%) 'neutral' and 11 (4.6%) 'worse' or 'much worse.' Student satisfaction and examination performance are both enhanced by ophthalmology eLearning. Similar eLearning modules may be suitable for other specialties and postgraduate learning.

  3. Prematures with and without Regressed Retinopathy of Prematurity: Comparison of Long-Term (6-10 Years) Ophthalmological Morbidity.

    Science.gov (United States)

    Cats, Bernard P.; Tan, Karel E. W. P.

    Reporting long-term ophthalmologic sequelae among ex-prematures at 6 to 10 years of age, this study compares 42 ex-premature infants who had had regressed forms of retinopathy of prematurity (ROP) during the neonatal period with 42 matched non-ROP ex-premature controls at 6 to 10 years of age. Subjects were subdivided into four groups: (1) ROP…

  4. Mamma diagnostics for MTRA (medical-radiological personnel)/RT (radiologists); Mammadiagnostik fuer MTRA/RT

    Energy Technology Data Exchange (ETDEWEB)

    Fischer, Uwe; Baum, Friedemann

    2014-07-01

    The text book on mamma diagnostics for MTRA (medical-radiological personnel)/RT (radiologists) covers the following issues: Anatomy, development and physiology of mammary glands; tumor development an breast cancer risk; pathology, non-imaging diagnostics; mammography: physical-technical fundamentals; mammography: analogue technique; mammography: digital technique; mammography: quality assurance; mammography: legal questions and radiation protection; mammography: new developments; mammography: setting technique; mammography: use and appraisal; mamma-sonography: technique and methodology; mamma-sonography: assignment and appraisal, mamma-NMR: technique and methodology; mamma-NMR: assignment and appraisal lymph node diagnostics; mamma interventions; biopsy; mamma interventions: marking examination concepts; therapeutic concepts; hygienic concepts; communication and interaction.

  5. Application of diagnostic system for diesel engine

    International Nuclear Information System (INIS)

    Yoshinaga, Takeshi; Hayashi, Haruji; Usui, Hiromi; Tsuruzono, Atsuya; Matsuda, Takafumi

    2008-01-01

    The Japan Atomic Power Company (JAPC) began to implement Condition Based Maintenance (CBM) for rotating components (pumps, fans and electric motors) from 1999 and, also has begun to apply diesel engine diagnostic techniques at our three nuclear power plants since 2004. This paper provides a description of the CBM methods used for diesel engines in nuclear standby service, a summary of the procedures to introduce these diagnostic techniques to our nuclear power plants, and experience with the application of these methods to JAPC nuclear power plants. (author)

  6. X-ray hot plasma diagnostics

    International Nuclear Information System (INIS)

    Cojocaru, E.

    1984-11-01

    X-ray plasma emission study is powerful diagnostic tool of hot plasmas. In this review article the main techniques of X-ray plasma emission measurement are shortly presented: X-ray spectrometry using absorbent filters, crystal and grating spectrometers, imaging techniques using pinhole cameras, X-ray microscopes and Fresnel zone plate cameras, X-ray plasma emission calorimetry. Advances in these techniques with examples for different hot plasma devices are also presentes. (author)

  7. Image enhancement of digital periapical radiographs according to diagnostic tasks

    International Nuclear Information System (INIS)

    Choi, Jin Woo; Han, Won Jeong; Kim, Eun Kyung

    2014-01-01

    his study was performed to investigate the effect of image enhancement of periapical radiographs according to the diagnostic task. Eighty digital intraoral radiographs were obtained from patients and classified into four groups according to the diagnostic tasks of dental caries, periodontal diseases, periapical lesions, and endodontic files. All images were enhanced differently by using five processing techniques. Three radiologists blindly compared the subjective image quality of the original images and the processed images using a 5-point scale. There were significant differences between the image quality of the processed images and that of the original images (P<0.01) in all the diagnostic task groups. Processing techniques showed significantly different efficacy according to the diagnostic task (P<0.01). Image enhancement affects the image quality differently depending on the diagnostic task. And the use of optimal parameters is important for each diagnostic task.

  8. Image enhancement of digital periapical radiographs according to diagnostic tasks

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Jin Woo; Han, Won Jeong; Kim, Eun Kyung [Dept. of Oral and Maxillofacial Radiology, Dankook University College of Dentistry, Cheonan (Korea, Republic of)

    2014-03-15

    his study was performed to investigate the effect of image enhancement of periapical radiographs according to the diagnostic task. Eighty digital intraoral radiographs were obtained from patients and classified into four groups according to the diagnostic tasks of dental caries, periodontal diseases, periapical lesions, and endodontic files. All images were enhanced differently by using five processing techniques. Three radiologists blindly compared the subjective image quality of the original images and the processed images using a 5-point scale. There were significant differences between the image quality of the processed images and that of the original images (P<0.01) in all the diagnostic task groups. Processing techniques showed significantly different efficacy according to the diagnostic task (P<0.01). Image enhancement affects the image quality differently depending on the diagnostic task. And the use of optimal parameters is important for each diagnostic task.

  9. Fungal disease detection in plants: Traditional assays, novel diagnostic techniques and biosensors.

    Science.gov (United States)

    Ray, Monalisa; Ray, Asit; Dash, Swagatika; Mishra, Abtar; Achary, K Gopinath; Nayak, Sanghamitra; Singh, Shikha

    2017-01-15

    Fungal diseases in commercially important plants results in a significant reduction in both quality and yield, often leading to the loss of an entire plant. In order to minimize the losses, it is essential to detect and identify the pathogens at an early stage. Early detection and accurate identification of pathogens can control the spread of infection. The present article provides a comprehensive overview of conventional methods, current trends and advances in fungal pathogen detection with an emphasis on biosensors. Traditional techniques are the "gold standard" in fungal detection which relies on symptoms, culture-based, morphological observation and biochemical identifications. In recent times, with the advancement of biotechnology, molecular and immunological approaches have revolutionized fungal disease detection. But the drawback lies in the fact that these methods require specific and expensive equipments. Thus, there is an urgent need for rapid, reliable, sensitive, cost effective and easy to use diagnostic methods for fungal pathogen detection. Biosensors would become a promising and attractive alternative, but they still have to be subjected to some modifications, improvements and proper validation for on-field use. Copyright © 2016 Elsevier B.V. All rights reserved.

  10. Diagnostic Accuracy of Imaging Modalities and Injection Techniques for the Diagnosis of Femoroacetabular Impingement/Labral Tear: A Systematic Review With Meta-analysis.

    Science.gov (United States)

    Reiman, Michael P; Thorborg, Kristian; Goode, Adam P; Cook, Chad E; Weir, Adam; Hölmich, Per

    2017-09-01

    Diagnosing femoroacetabular impingement/acetabular labral tear (FAI/ALT) and subsequently making a decision regarding surgery are based primarily on diagnostic imaging and intra-articular hip joint injection techniques of unknown accuracy. Summarize and evaluate the diagnostic accuracy and clinical utility of various imaging modalities and injection techniques relevant to hip FAI/ALT. Systematic review with meta-analysis. A computer-assisted literature search was conducted of MEDLINE, CINAHL, and EMBASE databases using keywords related to diagnostic accuracy of hip joint pathologic changes. The PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) guidelines were used for the search and reporting phases of the study. Quality assessment of bias and applicability was conducted using the Quality of Diagnostic Accuracy Studies (QUADAS) tool. Random effects models were used to summarize sensitivities (SN), specificities (SP), likelihood ratios (+LR and -LR), diagnostic odds ratios (DOR), and respective confidence intervals (CI). The search strategy and assessment for risk of bias revealed 25 articles scoring above 10/14 on the items of the QUADAS. Four studies investigated FAI, and the data were not pooled. Twenty articles on ALT qualified for meta-analysis. Pretest probability of ALT in the studies in this review was 81% (72%-88%), while the pretest probability of FAI diagnosis was 74% (95% CI, 51%-91%). The meta-analysis showed that computed tomography arthrography (CTA) demonstrated the strongest overall diagnostic accuracy: pooled SN 0.91 (95% CI, 0.83-0.96); SP 0.89 (95% CI, 0.74-0.97); +LR 6.28 (95% CI, 2.78-14.21); -LR 0.11 (95% CI, 0.06-0.21); and DOR 64.38 (95% CI, 19.17-216.21). High pretest probability of disease was demonstrated. Positive imaging findings increased the probability that a labral tear existed by a minimal to small degree with the use of magnetic resonance imaging/magnetic resonance angiogram (MRI/MRA) and ultrasound (US

  11. Is pediatric ophthalmology a popular subspecialty in India: Present scenario and future remedies

    Directory of Open Access Journals (Sweden)

    Sucheta Parija

    2017-01-01

    Full Text Available Purpose: The aim of the study was to assess the attitude and perceptions of residents regarding Pediatric Ophthalmology and Strabismus (POS subspecialty training. We also explored the possible barriers and solutions to promoting POS in India. Methods: A questionnaire consisting of 20 items, with a 5-point Likert scale, was provided to all postgraduate residents of Ophthalmology in the year 2013–2014. Semistructured interview of a selected panel of experts was carried out to understand the challenges, barriers, and opportunities for developing POS subspecialty in India. The data collected were coded and statistically analyzed using standard methods for quantitative and qualitative data. Results: Out of 81 residents, 69 responded (85.2%. The mean age of the respondents was 27.5 ± 1.23 years. Forty eight (69.0% residents reported that there was no structured surgical teaching and systematic periodic posting in this subspecialty during their residency program. Residents who stated difficulty to understand the subject were 59%. Pursuing POS as a career choice was indicated by 21.0%. Major attracting attributes of POS fellowship were intellectual stimulation (69.7% and independent operative skills (57.5%. Dissuading factors were difficulty to handle children (54.5% and stress factor (48.4%. Expert views were grouped under four domains, such as doctor–patient ratio, infrastructure, training opportunities, utilization, and accessibility to POS services. Conclusion: The study has provided useful insights into the preferential behavior among trainee resident doctors and reasons for not choosing POS as a possible choice of future fellowships.

  12. Extending the XNAT archive tool for image and analysis management in ophthalmology research

    Science.gov (United States)

    Wahle, Andreas; Lee, Kyungmoo; Harding, Adam T.; Garvin, Mona K.; Niemeijer, Meindert; Sonka, Milan; Abràmoff, Michael D.

    2013-03-01

    In ophthalmology, various modalities and tests are utilized to obtain vital information on the eye's structure and function. For example, optical coherence tomography (OCT) is utilized to diagnose, screen, and aid treatment of eye diseases like macular degeneration or glaucoma. Such data are complemented by photographic retinal fundus images and functional tests on the visual field. DICOM isn't widely used yet, though, and frequently images are encoded in proprietary formats. The eXtensible Neuroimaging Archive Tool (XNAT) is an open-source NIH-funded framework for research PACS and is in use at the University of Iowa for neurological research applications. Its use for ophthalmology was hence desirable but posed new challenges due to data types thus far not considered and the lack of standardized formats. We developed custom tools for data types not natively recognized by XNAT itself using XNAT's low-level REST API. Vendor-provided tools can be included as necessary to convert proprietary data sets into valid DICOM. Clients can access the data in a standardized format while still retaining the original format if needed by specific analysis tools. With respective project-specific permissions, results like segmentations or quantitative evaluations can be stored as additional resources to previously uploaded datasets. Applications can use our abstract-level Python or C/C++ API to communicate with the XNAT instance. This paper describes concepts and details of the designed upload script templates, which can be customized to the needs of specific projects, and the novel client-side communication API which allows integration into new or existing research applications.

  13. Laser diagnodent: a comparative study with other diagnostic techniques; Laser diagnodent: estudo comparativo com outras tecnicas de diagnostico

    Energy Technology Data Exchange (ETDEWEB)

    Godinho, Reugma Rego

    2002-07-01

    An evaluation of the Diagnodent equipment (Kavo Company, Germany) for the occlusal caries detection was dane through the comparison with other conventional diagnostic techniques, such as visual inspection, intra-oral micro camera and digital X-ray. The effectiveness of the equipment in the detection of hidden caries and its viability as a diagnosis method for caries in their initial stage was also studied. Fifty eight permanent molars and premolars teeth from patients with age between 6 and 30 years were studied. The obtained results indicated that the conventional methods employed for the caries diagnosis are unable to detect the carious lesion in its initial stage. The Diagnodent equipment has this capability to detect caries presenting a flawless surface, specially the hidden caries, allowing the dentist to decide between a preventive ar a conservative procedure. The main advantage of the Diagnodent is to be an objective method, compared to the visual and radiographic ones, that are dependent on the professional interpretation. The Diagnodent is, therefore, a promising alternative as an objective and standardized diagnosis method for the final diagnostic. (author)

  14. Development of a 2D temperature measurement technique for combustion diagnostics using 2-line atomic fluorescence

    Energy Technology Data Exchange (ETDEWEB)

    Engstroem, Johan

    2001-01-01

    The present thesis is concerned with the development and application of a novel planar laser-induced fluorescence (PLIF) technique for temperature measurements in a variety of combusting flows. Accurate measurement of temperature is an essential task in combustion diagnostics, since temperature is one of the most fundamental quantities for the characterization of combustion processes. The technique is based on two-line atomic fluorescence (TLAF) from small quantities of atomic indium (In) seeded into the fuel. It has been developed from small-scale experiments in laboratory flames to the point where practical combustion systems can be studied. The technique is conceptually simple and reveals temperature information in the post-flame regions. The viability of the technique has been tested in three extreme measurement situations: in spark ignition engine combustion, in ultra-lean combustion situations such as lean burning aero-engine concepts and, finally, in fuel-rich combustion. TLAF was successfully applied in an optical Sl engine using isooctane as fuel. The wide temperature sensitivity, 700 - 3000 K, of the technique using indium atoms allowed measurements over the entire combustion cycle in the engine to be performed. In applications in lean combustion a potential problem caused by the strong oxidation processes of indium atoms was encountered. This limits measurement times due to deposits of absorbing indium oxide on measurement windows. The seeding requirement is a disadvantage of the technique and can be a limitation in some applications. The results from experiments performed in sooting flames are very promising for thermometry measurements in such environments. Absorption by hydrocarbons and other native species was found to be negligible. Since low laser energies and low seeding concentrations could be used, the technique did not, unlike most other incoherent optical thermometry techniques, suffer interferences from LII of soot particles or LIF from PAH

  15. Phenotype analysis of early risk factors from electronic medical records improves image-derived diagnostic classifiers for optic nerve pathology

    Science.gov (United States)

    Chaganti, Shikha; Nabar, Kunal P.; Nelson, Katrina M.; Mawn, Louise A.; Landman, Bennett A.

    2017-03-01

    We examine imaging and electronic medical records (EMR) of 588 subjects over five major disease groups that affect optic nerve function. An objective evaluation of the role of imaging and EMR data in diagnosis of these conditions would improve understanding of these diseases and help in early intervention. We developed an automated image processing pipeline that identifies the orbital structures within the human eyes from computed tomography (CT) scans, calculates structural size, and performs volume measurements. We customized the EMR-based phenome-wide association study (PheWAS) to derive diagnostic EMR phenotypes that occur at least two years prior to the onset of the conditions of interest from a separate cohort of 28,411 ophthalmology patients. We used random forest classifiers to evaluate the predictive power of image-derived markers, EMR phenotypes, and clinical visual assessments in identifying disease cohorts from a control group of 763 patients without optic nerve disease. Image-derived markers showed more predictive power than clinical visual assessments or EMR phenotypes. However, the addition of EMR phenotypes to the imaging markers improves the classification accuracy against controls: the AUC improved from 0.67 to 0.88 for glaucoma, 0.73 to 0.78 for intrinsic optic nerve disease, 0.72 to 0.76 for optic nerve edema, 0.72 to 0.77 for orbital inflammation, and 0.81 to 0.85 for thyroid eye disease. This study illustrates the importance of diagnostic context for interpretation of image-derived markers and the proposed PheWAS technique provides a flexible approach for learning salient features of patient history and incorporating these data into traditional machine learning analyses.

  16. Mental stress as consequence and cause of vision loss: the dawn of psychosomatic ophthalmology for preventive and personalized medicine.

    Science.gov (United States)

    Sabel, Bernhard A; Wang, Jiaqi; Cárdenas-Morales, Lizbeth; Faiq, Muneeb; Heim, Christine

    2018-06-01

    The loss of vision after damage to the retina, optic nerve, or brain has often grave consequences in everyday life such as problems with recognizing faces, reading, or mobility. Because vision loss is considered to be irreversible and often progressive, patients experience continuous mental stress due to worries, anxiety, or fear with secondary consequences such as depression and social isolation. While prolonged mental stress is clearly a consequence of vision loss, it may also aggravate the situation. In fact, continuous stress and elevated cortisol levels negatively impact the eye and brain due to autonomous nervous system (sympathetic) imbalance and vascular dysregulation; hence stress may also be one of the major causes of visual system diseases such as glaucoma and optic neuropathy. Although stress is a known risk factor, its causal role in the development or progression of certain visual system disorders is not widely appreciated. This review of the literature discusses the relationship of stress and ophthalmological diseases. We conclude that stress is both consequence and cause of vision loss. This creates a vicious cycle of a downward spiral, in which initial vision loss creates stress which further accelerates vision loss, creating even more stress and so forth. This new psychosomatic perspective has several implications for clinical practice. Firstly, stress reduction and relaxation techniques (e.g., meditation, autogenic training, stress management training, and psychotherapy to learn to cope) should be recommended not only as complementary to traditional treatments of vision loss but possibly as preventive means to reduce progression of vision loss. Secondly, doctors should try their best to inculcate positivity and optimism in their patients while giving them the information the patients are entitled to, especially regarding the important value of stress reduction. In this way, the vicious cycle could be interrupted. More clinical studies are now

  17. Diagnostic difficulties with intraorbital foreign bogies: A case report

    International Nuclear Information System (INIS)

    Czarnowska, M.; Studniarek, D.; Socha-Korybalska, D.; Raczynska, K.

    2005-01-01

    As a result of trauma, a foreign body can enter the orbit and, via the orbital fissures, the cranial cavity. The most common are metallic, which are easily seen in X-rays, while low-density foreign bodies cause diagnostics problems. A 27-year old patient underwent trauma of the left orbit when walking in a forest. Twenty-four hours after the trauma the patient came to the ophthalmology outpatient clinic with complaints of inability to move the upper eyelid. The cause of the complaint was a 6-cm-long piece of wood within the orbit which was penetrating the middle cranial fossa via the upper orbital fissure. X-rays are the bases of diagnosing orbito-cranial injures and are a sufficient radiological method when the foreign body is metallic. CT is indispensable for the precise localization of low-density foreign bodies, the estimation of injury, and for diagnosis. CT scans are not typical for each foreign body. In this case, the hypo density of the wood was initially misinterpreted as an intra orbital air edema. (author)

  18. Practical X-ray diagnostics orthopedics and trauma surgery. Indication, adjustment technique and radiation protection

    International Nuclear Information System (INIS)

    Flechtenmacher, Johannes; Sabo, Desiderius

    2014-01-01

    The book on X-ray diagnostics in orthopedics and trauma surgery includes the following chapters: 1. Introduction: radiation protection, equipment technology radiological diagnostics of skeleton carcinomas, specific aspects of trauma surgery, special aspects of skeleton radiology for children. 2. X-ray diagnostics of different anatomical regions: ankle joint, knee, hips and pelvis, hand and wrist joint, elbow, shoulder, spinal cord. 3. Appendix: radiation protection according to the X-ray regulations.

  19. Development of advanced diagnostics for characterization of burning droplets in microgravity

    Science.gov (United States)

    Sankar, Subramanian; Buermann, Dale H.; Bachalo, William D.

    1995-01-01

    Diagnostic techniques currently used for microgravity research are generally not as advanced as those used in earth based gravity experiments. Diagnostic techniques for measuring the instantaneous radial temperature profile (or temperature gradients) within the burning droplet do not exist. Over the past few years, Aerometrics has been researching and developing a rainbow thermometric technique for measuring the droplet temperatures of burning droplets. This technique has recently been integrated with the phase Doppler interferometric technique to yield a diagnostic instrument that can be used to simultaneously measure the size, velocity, and temperature of burning droplets in complex spray flames. Also, the rainbow thermometric technique has been recently integrated with a point-diffraction interferometric technique for measuring the instantaneous gas phase temperature field surrounding a burning droplet. These research programs, apart from being very successful, have also helped us identify other innovative techniques for the characterization of burning droplets. For example, new techniques have been identified for measuring the instantaneous regression rate of burning droplets. Also, there is the possibility of extracting the instantaneous radial temperature distribution or the temperature gradients within a droplet during transient heating. What is important is that these diagnostic techniques have the potential for making use of inexpensive, light-weight, and rugged devices such as diode lasers and linear CCD arrays. As a result, they can be easily packaged for incorporation into microgravity drop-test and flight-test facilities. Furthermore, with the use of linear CCD arrays, data rates as high as 10-100 kHz can be easily achieved. This data rate is orders of magnitude higher than what is currently achievable. In this research and development program, a compact and rugged diagnostic system will be developed that can be used to measure instantaneous fuel

  20. Ophthalmological assessment of cannabis-induced persisting perception disorder: is there a direct retinal effect?

    Science.gov (United States)

    Zobor, Ditta; Strasser, Torsten; Zobor, Gergely; Schober, Franziska; Messias, Andre; Strauss, Olaf; Batra, Anil; Zrenner, Eberhart

    2015-04-01

    Cannabis is a psychotomimetic agent that induces impairment of sensory perception. We present detailed clinical and electrophysiological data of patients with hallucinogen persisting perception disorder (HPPD) after marijuana consumption. A HPPD patient and four heavy cannabis smokers with no visual disturbances (controls) underwent complete ophthalmological examination including psychophysical tests (visual acuity, color vision, visual field, and dark adaptation) and detailed electrophysiological examinations, including extended Ganzfeld ERG, multifocal ERG, and electrooculography (EOG). Furthermore, electrically evoked phosphene thresholds (EPTs) were measured to further evaluate retinal function. Ophthalmological and most electrophysiological examinations were within normal limits for the HPPD patient and for all control subjects. Interestingly, EOG results of the HPPD patient showed a slightly reduced fast oscillation ratio, diminished standing potentials of the slow oscillations, and a light peak within normal range resulting in higher Arden ratios. The EPTs of the patient were reduced, in particular for pulses with long durations (50 ms) causing visual sensations even at lowest possible currents of the neurostimulator. The control subjects did not reveal such alterations. Our findings suggest a direct effect of cannabinoids on the retina and retinal pigment epithelium function, which may be involved in disturbances of the visual function experienced after drug consumption. The observations presented here may contribute to the elucidation of the detailed mechanism. Furthermore, EOG and EPT measurements may be useful tools to demonstrate long-term retinal alterations in cannabis-induced HPPD in patients.

  1. Calibration issues for neutron diagnostics

    International Nuclear Information System (INIS)

    Sadler, G.J.; Adams, J.M.; Barnes, C.W.

    1997-10-01

    In order for ITER to meet its operational and programmatic goals, it will be necessary to measure a wide range of plasma parameters. Some of the required parameters e.g., neutron yield, fusion power and power density, ion temperature profile in the core plasma, and characteristics of confined and escaping alpha particle populations are best measured by fusion product diagnostic techniques. To make these measurements, ITER will have dedicated diagnostic systems, including radial and vertical neutron cameras, neutron and gamma ray spectrometers, internal and external fission chambers, a neutron activation system, and diagnostics for confined and escaping alpha particles. Engineering integration of many of these systems is in progress, and other systems are under investigation. This paper summarizes the present state of design of fusion product diagnostic systems for ITER and discusses expected measurement capability

  2. Study for the design method of multi-agent diagnostic system to improve diagnostic performance for similar abnormality

    International Nuclear Information System (INIS)

    Minowa, Hirotsugu; Gofuku, Akio

    2014-01-01

    Accidents on industrial plants cause large loss on human, economic, social credibility. In recent, studies of diagnostic methods using techniques of machine learning such as support vector machine is expected to detect the occurrence of abnormality in a plant early and correctly. There were reported that these diagnostic machines has high accuracy to diagnose the operating state of industrial plant under mono abnormality occurrence. But the each diagnostic machine on the multi-agent diagnostic system may misdiagnose similar abnormalities as a same abnormality if abnormalities to diagnose increases. That causes that a single diagnostic machine may show higher diagnostic performance than one of multi-agent diagnostic system because decision-making considering with misdiagnosis is difficult. Therefore, we study the design method for multi-agent diagnostic system to diagnose similar abnormality correctly. This method aimed to realize automatic generation of diagnostic system where the generation process and location of diagnostic machines are optimized to diagnose correctly the similar abnormalities which are evaluated from the similarity of process signals by statistical method. This paper explains our design method and reports the result evaluated our method applied to the process data of the fast-breeder reactor Monju

  3. Screening diagnostic program breast cancer

    International Nuclear Information System (INIS)

    Portnoj, L.M.; Zhakova, I.I.; Budnikova, N.V.; Rukhlyadko, E.D.

    1995-01-01

    The authors propose their screening program for detection of breast cancer. It includes the entire complex of present-day screening diagnostic methods, starting from an original system for the formation of groups at risk of breast cancer and completed by the direct diagnostic model of detection of the condition, oriented at a differentiated approach to the use of mammographic techniques. The proposed organizational and methodologic screening measures are both economic and diagnostically effective, thus meeting the principal requirements to screening programs. Screening of 8541 risk-groups patients helped detect 867 nodular formations, 244 of which were cancer and 623 benign formations. 8 refs., 3 figs.,

  4. Longitudinal Diagnostics for Short Electron Beam Bunches

    Energy Technology Data Exchange (ETDEWEB)

    Loos, H.; /SLAC

    2010-06-11

    Single-pass free electron lasers require high peak currents from ultra-short electron bunches to reach saturation and an accurate measurement of bunch length and longitudinal bunch profile is necessary to control the bunch compression process from low to high beam energy. The various state-of-the-art diagnostics methods from ps to fs time scales using coherent radiation detection, RF deflection, and other techniques are presented. The use of linear accelerators as drivers for free electron lasers (FEL) and the advent of single-pass (SASE) FELs has driven the development of a wide range of diagnostic techniques for measuring the length and longitudinal distribution of short and ultra-short electron bunches. For SASE FELs the radiation power and the length of the undulator needed to achieve saturation depend strongly on the charge density of the electron beam. In the case of X-ray FELs, this requires the accelerator to produce ultra-high brightness beams with micron size transverse normalized emittances and peak currents of several kA through several stages of magnetic bunch compression. Different longitudinal diagnostics are employed to measure the peak current and bunch profile along these stages. The measurement techniques can be distinguished into different classes. Coherent methods detect the light emitted from the beam by some coherent radiation process (spectroscopic measurement), or directly measure the Coulomb field traveling with the beam (electro-optic). Phase space manipulation techniques map the time coordinate onto a transverse dimension and then use conventional transverse beam diagnostics (transverse deflector, rf zero-phasing). Further methods measure the profile or duration of an incoherent light pulse emitted by the bunch at wavelengths much shorted than the bunch length (streak camera, fluctuation technique) or modulate the electron beam at an optical wavelength and then generate a narrow bandwidth radiation pulse with the longitudinal profile of

  5. Diagnostic methods and techniques in cervical cancer prevention Part II: Molecular diagnostics of HPV infection

    Directory of Open Access Journals (Sweden)

    Adriana Vince,

    2010-02-01

    Full Text Available Clinical diagnostics of HPV infection is based on analytically andclinically validated assays for qualitative detection of HPV DNAfrom high risk genotypes. New generation of HPV DNA assayscombines qualitative detection of 12 high-risk HPV genotypeswith HPV-16 and HPV-18 genotyping. New generation of HPVmolecular assays designed to increase clinical specificity of moleculartesting is based on detection of mRNA for E6 and E7.

  6. Exploration of problem-based learning combined with standardized patient in the teaching of basic science of ophthalmology

    Directory of Open Access Journals (Sweden)

    Jin Yan

    2015-08-01

    Full Text Available AIM:To investigate the effect of problem-based learning(PBLcombined with standardized patient(SPin the teaching of basic science of ophthalmology. METHODS: Sixty-four students of Optometry in grade 2012 were randomly divided into experimental group(n=32and control group(n=32. Traditional teaching method was implemented in control group while PBL combined with SP was applied in experimental group. At the end of term students were interviewed using self-administered questionnaire to obtain their evaluation for teaching effect. Measurement data were expressed as (-overx±s and analyzed by independent samples t test. Enumeration data were analyzed by χ2 test, and PRESULTS:The mean scores of theory test(83.22±3.75and experimental test(94.28±2.20in experimental group were significantly higher than theory test(70.72±3.95and experimental test(85.44±3.52in control group(all PPPCONCLUSION:Using PBL combined with SP teaching mode in basic science of ophthalmology can highly improve learning enthusiasm of students and cultivate self-learning ability of students, practice ability and ability of clinical analysis.

  7. Diagnostics of Gun Barrel Propellants

    National Research Council Canada - National Science Library

    Lederman, S

    1983-01-01

    A preliminary investigation of the applicability of the spontaneous Raman diagnostic technique to the determination of the temperature of the propellant gases in the vicinity of the muzzle of a 2Omm...

  8. Frequency and risk factors associated with dry eye in patients attending a tertiary care ophthalmology center in Mexico City

    Directory of Open Access Journals (Sweden)

    Martinez JD

    2016-07-01

    Full Text Available Jaime D Martinez,1 Anat Galor,2,3 Nallely Ramos-Betancourt,1 Andrés Lisker-Cervantes,1 Francisco Beltrán,1 Jorge Ozorno-Zárate,1 Valeria Sánchez-Huerta,1 Marco-Antonio Torres-Vera,1 Everardo Hernández-Quintela1 1Cornea and External Diseases Service, Asociación Para Evitar la Ceguera en Mexico (Association to prevent blindness in Mexico, Universidad Nacional Autónoma de México, Mexico City, Mexico; 2Department of Ophthalmology, Miami Veterans Affairs Medical Center, 3Cornea and External Diseases Division, Bascom Palmer Eye Institute, University of Miami, Miami, FL, USA Purpose: The purpose of this study was to ascertain the frequency and risk factors of dry eye (DE among patients attending a tertiary care ophthalmology center in Mexico.Methods: Approximately 338 consecutive new patients attending a tertiary care ophthalmology center in Mexico City underwent an ocular surface examination, which included tear film break-up time, fluorescein corneal staining, Schirmer’s test, and evaluation of meibum quality. Symptoms of DE were evaluated by the Ocular Surface Disease Index and Dry Eye Questionnaire-5. Information on demographics, exposures, past medical and ocular history, and medications was also collected.Results: The frequency of severe DE symptoms was found to be 43% based on the Ocular Surface Disease Index and 30% based on Dry Eye Questionnaire-5. Risk factors significantly associated with increased DE symptoms included dry mouth and gastrointestinal ulcer medications. With regard to signs, aqueous tear deficiency was a less-frequent finding (22% in our population than evaporative deficiency (94%. Risk factors associated with aqueous tear deficiency were dry mouth and diuretic use. No risk factors were associated with evaporative deficiency. Risk factors associated with meibomian gland dysfunction included old age, male sex, arthritis, and use of an antihypertensive. The only risk factor associated with corneal staining was dry

  9. Facilities and techniques for x-ray diagnostic calibration in the 100-eV to 100-keV energy range

    International Nuclear Information System (INIS)

    Gaines, J.L.; Wittmayer, F.J.

    1986-01-01

    The Lawrence Livermore National Laboratory (LLNL) has been a pioneer in the field of x-ray diagnostic calibration for more than 20 years. The authors built steady state x-ray sources capable of supplying fluorescent lines of high spectral purity in the 100-eV to 100-keV energy range, and these sources have been used in the calibration of x-ray detectors, mirrors, crystals, filters, and film. This paper discusses their calibration philosophy and techniques, and describes some of the x-ray sources. Examples of actual calibration data are presented as well

  10. Facilities and Techniques for X-Ray Diagnostic Calibration in the 100-eV to 100-keV Energy Range

    Science.gov (United States)

    Gaines, J. L.; Wittmayer, F. J.

    1986-08-01

    The Lawrence Livermore National Laboratory (LLNL) has been a pioneer in the field of x-ray diagnostic calibration for more than 20 years. We have built steady state x-ray sources capable of supplying fluorescent lines of high spectral purity in the 100-eV to 100-keV energy range, and these sources have been used in the calibration of x-ray detectors, mirrors, crystals, filters, and film. This paper discusses our calibration philosophy and techniques, and describes some of our x-ray sources. Examples of actual calibration data are presented as well.

  11. Facilities and techniques for x-ray diagnostic calibration in the 100-eV to 100-keV energy range

    International Nuclear Information System (INIS)

    Gaines, J.L.; Wittmayer, F.J.

    1986-06-01

    The Lawrence Livermore National Laboratory (LLNL) has been a pioneer in the field of x-ray diagnostic calibration for more than 20 years. We have built steady state x-ray sources capable of supplying fluorescent lines of high spectral purity in the 100-eV to 100-keV energy range, and these sources have been used in the calibration of x-ray detectors, mirrors, crystals, filters, and film. This paper discusses our calibration philosophy and techniques, and describes some of our x-ray sources. Examples of actual calibration data are presented as well

  12. [The German Ophthalmological Society (DOG) during the Period of National Socialism].

    Science.gov (United States)

    Rohrbach, J M

    2006-11-01

    Sixty-one years after the end of the Hitler dictatorship, the history of the German Ophthalmological Society (DOG) has still hardly been investigated. According to different sources, especially the reports of the DOG congresses 1934, 1936, 1938, and 1940, the following picture can be drawn: 1. The seizure of power ("Machtergreifung") of Adolf Hitler was appreciated by most of the DOG members. 2. After a change of the constitution the DOG came under the control of the "Reichsinnenministerium". However, it escaped the egalitarianism ("Gleichschaltung") and remained relatively independent. 3. Approximately 40 % of the heads of the German university eye clinics who were the most influential DOG representatives were members of the national socialistic German working party (NSDAP). Almost all of these joined the party in 1933 or later. 4. Up to the last congress in Dresden, 1940, the DOG activities were quite extensive. After that time the activities strongly declined. 5. The "Law for the prevention of genetically disabled offspring" ("Gesetz zur Verhütung erbkranken Nachwuchses") from January 1st 1934 was intensely discussed by the DOG. Some prominent ophthalmologists and DOG members were at least in part responsible for the sterilisations because of "congenital blindness". However, as far as it is known, the DOG itself did not intervene directly concerning the practice of sterilisation. 6. Between 1932 and 1940, the DOG lost approximately 12 % of its members. Many of these stemmed from foreign countries, and many were German Jews. The latter left the DOG, as Walther Löhlein stated after the end of the war, "voluntarily". However, a main reason for leaving the DOG was very likely the feeling of being unwanted. The national socialism had several disastrous effects on ophthalmology. Although single DOG members participated in the excesses, the DOG as an organization was not directly involved. However, taking into consideration that more than 10 % of the members of the

  13. Ophthalmological affectation: A way to mask Miastenia Gravis. A case purpose.

    Directory of Open Access Journals (Sweden)

    Néstor R. Sánchez Dacal

    2012-06-01

    Full Text Available Myasthenia Gravis MG is an autoimmune and chronic neuromuscular disease characterized by variable of weakness in the skeletal muscles that control the eye movements and it is confused with an ophthalmological disorder. With this presentation we pretend to systematize the Theoretical references about MG which allow making a correct diagnosis of the disease from the experience of a clinical case. The theory about MG regarding the presentation of the disease is discussed, emphasising on the significance of its differential diagnosis with an ophthalmopathy, which will contribute to apply a proper treatment and a satisfactory evolution of the patient, arriving to the conclusion that affectation of the III cranial pair is a way of frequent presentation of MG, being valuable the differential diagnosis of the ophthalmopaties in these entities.

  14. MTX [Microwave Tokamak Experiment] plasma diagnostic system

    International Nuclear Information System (INIS)

    Rice, B.W.; Hooper, E.B.; Brooksby, C.A.

    1987-01-01

    In this paper, a general overview of the MTX plasma diagnostics system is given. This includes a description of the MTX machine configuration and the overall facility layout. The data acquisition system and techniques for diagnostic signal transmission are also discussed. In addition, the diagnostic instruments planned for both an initial ohmic-heating set and a second FEL-heating set are described. The expected range of plasma parameters along with the planned plasma measurements will be reviewed. 7 refs., 5 figs

  15. Indications and new diagnostic techniques in micturating cystourethrographic studies

    International Nuclear Information System (INIS)

    Schuster, W.; Bruenger, J.

    1978-01-01

    Urological radiographic procedures on children are of great importance. The frequency of examinations is comparable to the number of Gl tract studies. In diagnosing chronically recurrent urinary tract infections, micturating cystourethrography is a valuable addition to excretory urography. Indications and performance of micturating cystourethrography at juvenile age are described. All measures reducing radiation exposure must be taken into consideration. New technological devices grant improved diagnostic information with a minimal radiation exposure for patients. (orig.) [de

  16. Effects of Different Compression Techniques on Diagnostic Accuracies of Breast Masses on Digitized Mammograms

    International Nuclear Information System (INIS)

    Zhigang Liang; Xiangying Du; Jiabin Liu; Yanhui Yang; Dongdong Rong; Xinyu Y ao; Kuncheng Li

    2008-01-01

    Background: The JPEG 2000 compression technique has recently been introduced into the medical imaging field. It is critical to understand the effects of this technique on the detection of breast masses on digitized images by human observers. Purpose: To evaluate whether lossless and lossy techniques affect the diagnostic results of malignant and benign breast masses on digitized mammograms. Material and Methods: A total of 90 screen-film mammograms including craniocaudal and lateral views obtained from 45 patients were selected by two non-observing radiologists. Of these, 22 cases were benign lesions and 23 cases were malignant. The mammographic films were digitized by a laser film digitizer, and compressed to three levels (lossless and lossy 20:1 and 40:1) using the JPEG 2000 wavelet-based image compression algorithm. Four radiologists with 10-12 years' experience in mammography interpreted the original and compressed images. The time interval was 3 weeks for each reading session. A five-point malignancy scale was used, with a score of 1 corresponding to definitely not a malignant mass, a score of 2 referring to not a malignant mass, a score of 3 meaning possibly a malignant mass, a score of 4 being probably a malignant mass, and a score of 5 interpreted as definitely a malignant mass. The radiologists' performance was evaluated using receiver operating characteristic analysis. Results: The average Az values for all radiologists decreased from 0.8933 for the original uncompressed images to 0.8299 for the images compressed at 40:1. This difference was not statistically significant. The detection accuracy of the original images was better than that of the compressed images, and the Az values decreased with increasing compression ratio. Conclusion: Digitized mammograms compressed at 40:1 could be used to substitute original images in the diagnosis of breast cancer

  17. Principles for new optical techniques in medical diagnostics for mHealth applications

    Science.gov (United States)

    Balsam, Joshua Michael

    Medical diagnostics is a critical element of effective medical treatment. However, many modern and emerging diagnostic technologies are not affordable or compatible with the needs and conditions found in low-income and middle-income countries and regions. Resource-poor areas require low-cost, robust, easy-to-use, and portable diagnostics devices compatible with telemedicine (i.e. mHealth) that can be adapted to meet diverse medical needs. Many suitable devices will need to be based on optical technologies, which are used for many types of biological analyses. This dissertation describes the fabrication and detection principles for several low-cost optical technologies for mHealth applications including: (1) a webcam based multi-wavelength fluorescence plate reader, (2) a lens-free optical detector used for the detection of Botulinum A neurotoxin activity, (3) a low cost micro-array reader that allows the performance of typical fluorescence based assays demonstrated for the detection of the toxin staphylococcal enterotoxin (SEB), and (4) a wide-field flow cytometer for high throughput detection of fluorescently labeled rare cells. This dissertation discusses how these technologies can be harnessed using readily available consumer electronics components such as webcams, cell phones, CCD cameras, LEDs, and laser diodes. There are challenges in developing devices with sufficient sensitivity and specificity, and approaches are presented to overcoming these challenges to create optical detectors that can serve as low cost medical diagnostics in resource-poor settings for mHealth.

  18. Uncertainty Management for Diagnostics and Prognostics of Batteries using Bayesian Techniques

    Data.gov (United States)

    National Aeronautics and Space Administration — Uncertainty management has always been the key hurdle faced by diagnostics and prognostics algorithms. A Bayesian treatment of this problem provides an elegant and...

  19. Primary Sjögren's syndrome and keratoconjunctivitis sicca: Diagnostic methods, frequency and social disease aspects

    DEFF Research Database (Denmark)

    Bjerrum, Kirsten Birgitte

    ophthalmology, Sjögren's syndrome, keratoconjunctivitis sicca, conjunctiva, dry eye, Schirmer-1 test, Rose Bengal score, break-up time, tear film, Copenhagen criteria......ophthalmology, Sjögren's syndrome, keratoconjunctivitis sicca, conjunctiva, dry eye, Schirmer-1 test, Rose Bengal score, break-up time, tear film, Copenhagen criteria...

  20. Nuclear diagnostics for inertial confinement fusion implosions

    International Nuclear Information System (INIS)

    Murphy, T.J.

    1997-01-01

    This abstract contains viewgraphs on nuclear diagnostic techniques for inertial confinement fusion implosions. The viewgraphs contain information on: reactions of interest in ICF; advantages and disadvantages of these methods; the properties nuclear techniques can measure; and some specifics on the detectors used

  1. Diagnostic studies in amyloidosis

    NARCIS (Netherlands)

    Hazenberg, Bouke Pier Cornelis

    2007-01-01

    In this thesis two diagnostic techniques are studied in amyloidosis. Systemic amyloidosis is characterized by deposition of amyloid fibrils (tiny fibres) throughout the body resulting in damage of vital organs. Amyloid can be detected in a tissue specimen stained with Congo red: red-stained amyloid

  2. X-ray diagnostics of female genitals in child age

    International Nuclear Information System (INIS)

    Willich, E.; Benz-Bohm, G.; Koeln Univ.

    1982-01-01

    The experiences of special X-ray diagnostics of female genitals are described, that were made in 41 children within a period of 12 years. The superiority of the X-ray-technique arises from the impossibility of the manual examination in newborn and infants and the avoidance of diagnostic techniques like laparoscopy or laparotomy. All the examination techniques are described. In intersexualmarked patients the discrimination into six types after Shopfner is preferred. Malformations and tumours are dealt with briefly. The relations between skeleton and female genitals are pointed out at the example of the gonadal dysgenesis. (orig.) [de

  3. Survey of intravitreal injection techniques among retina specialists in Israel

    Directory of Open Access Journals (Sweden)

    Segal O

    2016-06-01

    Full Text Available Ori Segal,1,2 Yael Segal-Trivitz,1,3 Arie Y Nemet,1,2 Noa Geffen,1,2 Ronit Nesher,1,2 Michael Mimouni4 1Department of Ophthalmology, Meir Medical Center, Kfar Saba, 2The Sackler School of Medicine, Tel Aviv University, Tel Aviv, 3Department of Psychiatry, Geha Psychiatric Hospital, Petah Tikva, 4Department of Ophthalmology, Rambam Health Care Campus, Haifa, Israel Purpose: The purpose of this study was to describe antivascular endothelial growth factor intravitreal injection techniques of retinal specialists in order to establish a cornerstone for future practice guidelines. Methods: All members of the Israeli Retina Society were contacted by email to complete an anonymous, 19-question, Internet-based survey regarding their intravitreal injection techniques. Results: Overall, 66% (52/79 completed the survey. Most (98% do not instruct patients to discontinue anticoagulant therapy and 92% prescribe treatment for patients in the waiting room. Three quarters wear sterile gloves and prepare the patient in the supine position. A majority (71% use sterile surgical draping. All respondents apply topical analgesics and a majority (69% measure the distance from the limbus to the injection site. A minority (21% displace the conjunctiva prior to injection. A majority of the survey participants use a 30-gauge needle and the most common quadrant for injection is superotemporal (33%. Less than half routinely assess postinjection optic nerve perfusion (44%. A majority (92% apply prophylactic antibiotics immediately after the injection. Conclusion: The majority of retina specialists perform intravitreal injections similarly. However, a relatively large minority performs this procedure differently. Due to the extremely low percentage of complications, it seems as though such differences do not increase the risk. However, more evidence-based medicine, a cornerstone for practice guidelines, is required in order to identify the intravitreal injection techniques

  4. Diagnostics for high-brightness beams

    International Nuclear Information System (INIS)

    Shafer, R.E.

    1990-01-01

    Special techniques are required for beam diagnostics on high-brightness particle beams. Examples of high-brightness beams include low-emittance proton linacs (either pulsed or CW), electron linacs suitable for free-electron-laser applications, and future linear colliders. Non-interceptive and minimally-interceptive techniques for measuring beam current, position, profile, and transverse and longitudinal emittance will be reviewed. Included will be stripline, wire scanner, laser neutralization, beam-beam scattering, interceptive microgratings, spontaneous emission, optical transition radiation, and other techniques. 24 refs

  5. Complex polarimetric and spectral techniques in diagnostics of blood plasma of patients with ovarian cancer as a preliminary stage molecular genetic screening

    Science.gov (United States)

    Grzegorzewski, B.; Peresunko, O. P.; Yermolenko, S. B.

    2018-01-01

    This work is devoted to the substantiation and selection of patients with ovarian cancer (OC) for the purpose of conducting expensive molecular genetic studies on genotyping. As diagnostic methods have been used ultraviolet spectrometry samples of blood plasma in the liquid state, infrared spectroscopy middle range (2,5 - 25 microns) dry residue of plasma polarization and laser diagnostic technique of thin histological sections of biological tissues. Obtained results showed that the use of spectrophotometry in the range of 1000-3000 cm-1 allowed to establish quantitative parameters of the plasma absorption rate of blood of patients in the third group in different ranges, which would allow in the future to conduct an express analysis of the patient's condition (procedure screening) for further molecular-genetic typing on BRCA I and II.

  6. Laser Diagnostics for Reacting Flows

    National Research Council Canada - National Science Library

    Hanson, Ronald K

    2007-01-01

    ... (UV) or infrared (IR) wavelengths. The cw lasers were spectrally narrow, allowing study of innovative diagnostics based on spectral lineshapes, while the pulsed lasers provided intense bursts of photons needed for techniques based on LIF...

  7. The role of diagnostic radiology in compressive and entrapment neuropathies

    International Nuclear Information System (INIS)

    Spratt, J.D.; Stanley, A.J.; Hide, I.G.; Campbell, R.S.D.; Grainger, A.J.

    2002-01-01

    Diagnostic imaging is increasingly being utilised to aid the diagnosis of compression and entrapment neuropathies. Cross-sectional imaging, primarily ultrasound and magnetic resonance imaging, can provide exquisite anatomical detail of peripheral nerves and the changes that may occur as a result of compression. Imaging can provide a useful diagnostic aid to clinicians, which may supplement clinical evaluation, and may eventually provide an alternative to other diagnostic techniques such as nerve conduction studies. This article describes the abnormalities that may be demonstrated by current imaging techniques, and critically analyses the impact of imaging in diagnosis of peripheral compressive neuropathy. (orig.)

  8. The role of diagnostic radiology in compressive and entrapment neuropathies

    Energy Technology Data Exchange (ETDEWEB)

    Spratt, J.D.; Stanley, A.J.; Hide, I.G.; Campbell, R.S.D. [Department of Radiology, James Cook University Hospital, Middlesbrough, TS4 3BW (United Kingdom); Grainger, A.J. [Department of Radiology, Leeds General Infirmary, Leeds (United Kingdom)

    2002-09-01

    Diagnostic imaging is increasingly being utilised to aid the diagnosis of compression and entrapment neuropathies. Cross-sectional imaging, primarily ultrasound and magnetic resonance imaging, can provide exquisite anatomical detail of peripheral nerves and the changes that may occur as a result of compression. Imaging can provide a useful diagnostic aid to clinicians, which may supplement clinical evaluation, and may eventually provide an alternative to other diagnostic techniques such as nerve conduction studies. This article describes the abnormalities that may be demonstrated by current imaging techniques, and critically analyses the impact of imaging in diagnosis of peripheral compressive neuropathy. (orig.)

  9. Skeletal diseases. Diagnostic clinical radiology and differential diagnostics. 2. rev. and enl. ed.

    International Nuclear Information System (INIS)

    Freyschmidt, J.

    1997-01-01

    The book focuses on the diagnostic evaluation of idiopathic diseases of the skeleton and bone joints, also including the fundamental healing processes of bone fractures, particularly of stress-induced and pathologic fractures. Ample space has been given to the description and imaging of the course of diseases under treatment by up-to-date therapies, as e.g. for ostitis deformans Paget's disease, or skeletal metastases. This second edition of the book incorporates the progress achieved over the last five years in skeletal diagnostics. The advances in this field have been resulting from basic research work, for instance in molecular biology, or from a variety of completed studies relating to clinical medicine, laboratory chemistry, histopathology and radiology of skeletal diseases, and from experience obtained with the diagnostic radiology methods and techniques, with the potentials and constraints of magnetic resonance imaging (MRI) today being more critically assessed than five years ago. MRI is a modality currently meeting with interest in the context of search for additional diagnostic information, new definition of complete pictures of diseases, or false or overinterpretation of diagnostic findings. (orig./MG). 431 figs [de

  10. Diagnostic techniques in deflagration and detonation studies.

    Science.gov (United States)

    Proud, William G; Williamson, David M; Field, John E; Walley, Stephen M

    2015-12-01

    Advances in experimental, high-speed techniques can be used to explore the processes occurring within energetic materials. This review describes techniques used to study a wide range of processes: hot-spot formation, ignition thresholds, deflagration, sensitivity and finally the detonation process. As this is a wide field the focus will be on small-scale experiments and quantitative studies. It is important that such studies are linked to predictive models, which inform the experimental design process. The stimuli range includes, thermal ignition, drop-weight, Hopkinson Bar and Plate Impact studies. Studies made with inert simulants are also included as these are important in differentiating between reactive response and purely mechanical behaviour.

  11. Skin manifestations in sulfur mustard exposed victims with ophthalmologic complications: Association between early and late phase

    Directory of Open Access Journals (Sweden)

    Somayeh Hejazi, MD

    Full Text Available Context: Sulfur mustard (SM was used during the Iraq-Iran war (1980–1988. Exposed veterans continue to suffer from its ocular, skin, and respiratory complications. Objective: We aimed to evaluate associations between early (at the time of acute exposure and decades later skin manifestations in individuals with severe ophthalmologic complications secondary to sulfur mustard exposure. Materials and methods: One hundred forty-nine veterans with severe ocular injuries were evaluated for acute and chronic skin complications. Logistic regression models were used to examine the associations between early and late skin manifestations. Results: Late skin complaints were observed in nearly all survivors who had early skin lesions (131 out of 137; 95.62%. Seven out of 12 patients (58.33% who did not have early skin lesions ultimately developed late skin complications. There was a significant relationship between the presence of lesions at the time of exposure and developing late skin complaints (two-sided Fisher's exact test, OR = 15.59, p < 0.001. There was an association between having at least one early skin lesion and occurrence of late skin complications. Survivors with blisters at the time of chemical exposure were more likely to complain of itching (95% CI: 3.63–25.97, p < 0.001, burning (OR = 11.16; 95% CI: 2.97–41.89, p < 0.001, pigmentation changes (OR = 10.17; 95% CI: 2.54–40.75, p = 0.001, dryness (OR = 6.71, 95% CI: 1.22–37.01, p = 0.03 or cherry angioma (OR = 2.59; 95% CI:1.21–5.55, p = 0.01 during the late phase. Using multivariate logistic models, early blisters remained significantly associated with latent skin complaints. Of note, the genitalia and great flexure areas were the most involved anatomical sites for both early and late skin lesions in SM exposed survivors. Conclusion: According to this study, the presence of blisters at the time of exposure to SM is the most important predictor of developing

  12. Evaluation of diagnostic technique for degradation of low-voltage electric cables with silicone rubber insulator

    International Nuclear Information System (INIS)

    Mikami, Masao

    2005-01-01

    As a part of countermeasures against ageing problems of nuclear power plants, it is requested to establish non-destructive diagnostic technique for their degradation of low voltage electric cables and assessment standard of their life. Having aimed at investigating the degradation of low-voltage electric cable with silicone rubber insulator, change of its surface hardness at elevated temperature were measured by indenter modules. Moreover, we also measured the elongation at break, which is regarded as general degradation index of electric cables, and the surface hardness with a micro hardness meter. Consequently, it is seen that the indenter modulus measurement is (1) capable to obtain general feature of the thermal degradation of silicone rubber insulator, (2) applicable to diagnose the degree of degradation of the electric cable by converting the result to elongation at break, (3) well correlated with the hardness measurement of the electric cable with the micro hardness meter. (author)

  13. Diagnostic imaging in medicine. 2. ed.

    International Nuclear Information System (INIS)

    Reba, R.C.; Goodenough, D.J.

    1984-01-01

    This book describes to practitioners the evolutionary progression of new non-invasive diagnostic imaging techniques. The utility of the procedures is also described in a series of state-of-the-art lectures given by outstanding international clinical investigators from NATO countries. Subjects of the papers include the following: advances in source and detector technology, acoustical imaging, NMR and microwave imaging, positron and single photon emission tomography, digital radiography and image processing and display techniques. Fundamental papers describing the theory of non-invasive procedures are included along with papers describing clinical examinations. Examples of utility and studies of diseases of the abdomen and pelvis, heart and lung, and central nervous system are included. Cost-effective and cost-benefit assessment of the new high technology procedures, as well as the use of diagnostic imaging techniques in developing countries are also presented. An index of leading topics completes the volume. (orig.)

  14. In-bore instrumentation/diagnostics for large-bore EMLs

    International Nuclear Information System (INIS)

    Fernandez, M.J.; Ager, S.A.; Hudson, R.D.

    1991-01-01

    This paper reports on a flying laboratory technique of in-bore diagnostics for large-bore electromagnetic launchers (EMLs). The high pressure, heat, and magnetic flux environment of the EML and its containment structures do not allow easy implementation of conventional diagnostic techniques. Researchers have relied on remote sensing methods, such as B probes (isolated from the bore), for data. The accuracy and relevance of such discrete, remote measurement is somewhat questionable. An in-house program has been initiated to determine the feasibility of making measurement of EML parameters on board a projectile. This technique utilizes off-the-shelf components in a configuration that has been proven effective in measuring projectile acceleration in the bore of propellant driven guns

  15. Active and Passive Diagnostic Signatures of Special Nuclear Materials

    Energy Technology Data Exchange (ETDEWEB)

    Myers, William L. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Karpius, Peter Joseph [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Myers, Steven Charles [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-05-26

    An overview will be given discussing signatures associated with special nuclear materials acquired using both active and passive diagnostic techniques. Examples of how technology advancements have helped improve diagnostic capabilities to meet the challenges of today’s applications will be discussed.

  16. The Diagnostic Challenge Competition: Probabilistic Techniques for Fault Diagnosis in Electrical Power Systems

    Science.gov (United States)

    Ricks, Brian W.; Mengshoel, Ole J.

    2009-01-01

    Reliable systems health management is an important research area of NASA. A health management system that can accurately and quickly diagnose faults in various on-board systems of a vehicle will play a key role in the success of current and future NASA missions. We introduce in this paper the ProDiagnose algorithm, a diagnostic algorithm that uses a probabilistic approach, accomplished with Bayesian Network models compiled to Arithmetic Circuits, to diagnose these systems. We describe the ProDiagnose algorithm, how it works, and the probabilistic models involved. We show by experimentation on two Electrical Power Systems based on the ADAPT testbed, used in the Diagnostic Challenge Competition (DX 09), that ProDiagnose can produce results with over 96% accuracy and less than 1 second mean diagnostic time.

  17. Optimized design of shields for diagnostic X rays with NCRP 147 technique; Diseno optimizado de blindajes para rayos X diagnostico con tecnica NCRP 147

    Energy Technology Data Exchange (ETDEWEB)

    Gama T, G. [Calidad XXI SA de CV, Zacatecas 67-007 Col. Roma, 06700 Mexico D.F. (Mexico)]. e-mail: cxxi@prodigy.net.mx

    2006-07-01

    A comparison among the design techniques of shielding for X-ray diagnostic rooms with the NCRP 49 (1976) report technique, AAPM 39 (1993) Y the one of the NCRP 147 (2005) technique. The designs correspond to a room of conventional X-rays, one of fluoroscopy, one of tomography Y one of mammography. In all the cases it demonstrates that the NCRP 49 technique overestimate the shieldings. The causes of the overestimation of the NCRP 49 can be attributed to: a) high values of the work charge that don't consider the spectral fluence of the photons that are present in each room, b) to the differences in the values of the kerma in air without attenuation for the dispersed primary radiation Y of leakage among both reports. (Author)

  18. Technical diagnostics - equipment monitoring for increasing safety and availability of nuclear power plants

    International Nuclear Information System (INIS)

    Sturm, A.; Foerster, R.

    1977-01-01

    Utilization of technical diagnostics in equipment monitoring of nuclear power plants for ensuring nuclear safety, economic availability, and for decision making on necessary maintenance is reviewed. Technical diagnostics is subdivided into inspection and early detection of malfunctions. Moreover, combination of technical diagnostics and equipment monitoring, integration of technical diagnostics into maintenance strategy, and problems of introducing early detection of malfunctions into maintenance management of nuclear power plants are also discussed. In addition, a compilation of measuring techniques used in technical diagnostics has been made. The international state of the art of equipment monitoring in PWR nuclear power plants is illustrated by description of the sound and vibration measuring techniques. (author)

  19. A Self-Diagnostic System for the M6 Accelerometer

    Science.gov (United States)

    Flanagan, Patrick M.; Lekki, John

    2001-01-01

    The design of a Self-Diagnostic (SD) accelerometer system for the Space Shuttle Main Engine is presented. This retrofit system connects diagnostic electronic hardware and software to the current M6 accelerometer system. This paper discusses the general operation of the M6 accelerometer SD system and procedures for developing and evaluating the SD system. Signal processing techniques using M6 accelerometer diagnostic data are explained. Test results include diagnostic data responding to changing ambient temperature, mounting torque and base mounting impedance.

  20. Cerebral visual impairment in children: Causes and associated ophthalmological problems.

    Science.gov (United States)

    Pehere, Niranjan; Chougule, Pratik; Dutton, Gordon N

    2018-06-01

    The aim of this study is to identify common causes, associated ophthalmological abnormalities, and systemic comorbidities in children in Andhra Pradesh, India, with cerebral visual impairment (CVI). A retrospective review of case records of all children aged visual impairment was seen in 88.8%, and 11.2% had high functioning CVI. Fifty-eight (46.4%) patients had significant refractive errors, 40 (32.25%) had strabismus, 4 (3.2%) had visually significant cataract, and 40 (32%) had optic atrophy. Motor delay was observed in 39.5%, speech delay was evident in 22.4%, and cognitive delay in 16%. HIE is the most common cause (one-third) of CVI in our population, and the majority of them presented at age visual impairment (88.8%). A significant number of them have treatable ophthalmic conditions such as refractive errors (46.4%), accommodative insufficiency (12.1%), and cataract (3.2%), and more than one-third of them also have delay in other areas of development.

  1. Mechanical system diagnostics using vibration testing techniques

    Science.gov (United States)

    Mcleod, Catherine D.; Raju, P. K.; Crocker, M. J.

    1990-01-01

    The 'Cepstrum' technique of vibration-path identification allows the recovery of the transfer function of a system with little knowledge as to its excitation force, by means of a mathematical manipulation of the system output in conjunction with subtraction of part of the output and suitable signal processing. An experimental program has been conducted to evaluate the usefulness of this technique in the cases of simple, cantilever-beam and free-free plate structures as well as in that of a complex mechanical system. On the basis of the transfer functions thus recovered, it was possible to evaluate the shifts in the resonance frequencies of a structure due to the presence of defects.

  2. Repercusión oftalmológica de los traumatismos maxilofaciales Ophthalmological repercussion of maxillofacial traumatisms

    Directory of Open Access Journals (Sweden)

    José Manuel Díaz Fernández

    2004-12-01

    Full Text Available Se presenta un estudio prospectivo de 40 pacientes afectados por traumatismos maxilofaciales con lesiones oftalmológicas asociadas, asistidos en el Hospital Clinico quirúrgico Docente "Saturnino Lora" de Santiago de Cuba, durante el año 1995. La lesión oftalmológica más frecuente fue el hematoma palpebral, asociado con un porcentaje significativo de lesiones graves, las cuales estaban en relación con el área afectada durante el traumatismo. Se comportó con incidencia elevada la agudeza visual dentro de los límites normales. La secuela que más se presentó fue la cicatriz deformante de anejos. Se reportan casos de secuelas graves como la pérdida del globo ocular. Los estudios electrofisiológicos demostraron su importancia para la evaluación funcional de las lesiones oftalmológicas.prospective study of 40 patients suffering from maxillofacial traumatisms with associated ophthalmological injuries that recieved attention at "Saturnino Lora" Clinical and Surgical Teaching Hospital, in Santiago de Cuba, in 1995, was presented. The most frequent ophthalmological injury was the palpebral hematoma associated with a significant percentage of severe injuries, which were related to the area affected during traumatism. Visual acuity had an elevated incidence within the normal limits. The adnexa deforming scar was the most common sequela. Cases of severe sequelae, such as the loss of the eyeball, were reported.

  3. Diagnostic imaging in internal medicine

    International Nuclear Information System (INIS)

    Eisenberg, R.L.

    1985-01-01

    This book examines medical diagnostic techniques. Topics considered include biological considerations in the approach to clinical medicines; infectious diseases; disorders of the heart; disorders of the vascular system; disorders of the respiratory system; diseases of the kidneys and urinary tract; disorders of the alimentary tract; disorders of the hepatobiliary system and pancreas; disorders of the hematopoietic system; disorders of bone and bone mineralization; disorders of the joints, connective tissues, and striated muscles; disorders of the nervous system; miscellaneous disorders; and procedures in diagnostic imaging

  4. Diagnostics for induction accelerators

    International Nuclear Information System (INIS)

    Fessenden, T.J.

    1996-04-01

    The induction accelerator was conceived by N. C. Christofilos and first realized as the Astron accelerator that operated at LLNL from the early 1960's to the end of 1975. This accelerator generated electron beams at energies near 6 MeV with typical currents of 600 Amperes in 400 ns pulses. The Advanced Test Accelerator (ATA) built at Livermore's Site 300 produced 10,000 Ampere beams with pulse widths of 70 ns at energies approaching 50 MeV. Several other electron and ion induction accelerators have been fabricated at LLNL and LBNL. This paper reviews the principal diagnostics developed through efforts by scientists at both laboratories for measuring the current, position, energy, and emittance of beams generated by these high current, short pulse accelerators. Many of these diagnostics are closely related to those developed for other accelerators. However, the very fast and intense current pulses often require special diagnostic techniques and considerations. The physics and design of the more unique diagnostics developed for electron induction accelerators are presented and discussed in detail

  5. Rifle Marksmanship Diagnostic and Training Guide

    Science.gov (United States)

    2011-05-01

    there any techniques you use to help prepare Soldiers to transition to firing with aiming lights (PEQ-2 or PAQ -4) and night vision goggles (ARM 1)? If...firing skills with the PAQ -4? A‐5    15. Are there any other diagnostic techniques you use that we haven’t discussed? a. Think back on your

  6. Environmental sensing and combustion diagnostics

    International Nuclear Information System (INIS)

    Santoleri, J.J.

    1991-01-01

    This book contains proceedings of Environmental Sensing and Combustion Diagnostics. Topics covered include: Incineration Systems Applications, Permitting, And Monitoring Overview; Infrared Techniques Applied to Incineration Systems; Continuous Emission Monitors; Analyzers and Sensors for Process Control And Environmental Monitoring

  7. Diagnostic techniques in cerebral artery occlusions

    Energy Technology Data Exchange (ETDEWEB)

    Huber, P

    1972-01-01

    In two-thrids of the cases of cerebral artery occlusions ophthalmodynamotry, thermography, and the fluorescein test are sufficient. In cases where these give insufficient data, scintigraphy is the preferred screening method. For determination of the regional blood flow /sup 133/Xe is used. Angiographic investigation, however, is the method that gives the most clinically valuable data. The techniques used and the risks inherent in the method are described. (JSR)

  8. Diagnostic accuracy of dynamic contrast-enhanced MR imaging of renal masses with rapid-acquisition spin-echo technique

    International Nuclear Information System (INIS)

    Eilenberg, S.S.; Lee, J.K.T.; Brown, J.J.; Heiken, J.P.; Mirowitz, S.A.

    1990-01-01

    This paper compares the diagnostic accuracy of Gd-DTPA-enhanced rapid-acquisition spin-echo (RASE) imaging with standard spin-echo techniques for detecting renal cysts and solid renal neoplasms. RASE imaging combines a short TR (275 msec)/short TE (10 msec), single excitation pulse sequence with half-Fourier data sampling. Eighteen patients with CT evidence of renal masses were first evaluated with standard T1-and T2-weighted SE sequences. Pre- and serial postcontrast (Cd-DTPA, 0.1 mmol./kg) RASE sequences were then performed during suspended respiration. A final set of postcontrast images was obtained with the standard T1-weighted SE sequence. Each set of MR images was first reviewed separately (ie, T1, T2, pre- and post-contrast RASE, etc)

  9. Diagnostics of atmospheric pressure air plasmas

    International Nuclear Information System (INIS)

    Laux, C.O.; Kruger, C.H.; Zare, R.N.

    2001-01-01

    Atmospheric pressure air plasmas are often thought to be in Local Thermodynamics Equilibrium (LTE) owing to fast interspecies collisional exchanges at high pressure. As will be seen here, this assumption cannot be relied upon, particularly with respect to optical diagnostics. Large velocity gradients in flowing plasmas and/or elevated electron temperatures created by electrical discharges can result in large departures from chemical and thermal equilibrium. Diagnostic techniques based on optical emission spectroscopy (OES) and Cavity Ring-Down Spectroscopy (CRDS) have been developed and applied at Stanford University to the investigation of atmospheric pressure plasmas under conditions ranging from thermal and chemical equilibrium to thermochemical nonequilibrium. This article presents a review of selected temperature and species concentration measurement techniques useful for the study of air and nitrogen plasmas

  10. Determination of Risk Factors and Treatment of Dry Eye Disease in Type 1 Diabetes Before Corneal Complications at Sindh Institute of Ophthalmology And Visual Sciences.

    Science.gov (United States)

    Shujaat, Shehnilla; Jawed, Muhammad; Memon, Shahzad; Talpur, Khalid Iqbal

    2017-01-01

    The objective of this study was to assess and determine the risk factors and treatment of dry eye disease in type 1 diabetes before any ocular surface or corneal complication occurs. This study was conducted at Sindh Institute of Ophthalmology And Visual Sciences, Hyderabad, Pakistan. Subjects and methods for observational study were undertaken at the Department of Ophthalmology Sindh Institute Of Ophthalmology And Visual Sciences, Hyderabad, Pakistan. Hundred confirmed cases of type 1 diabetes were included in the study by non probability convenience sampling. Tear film breakup time and schrimer test were carried out to determine dry eye disease. Data was collected by self-prepared questionnaire and entered and analyzed by using Statistical Program for Social Sciences (SPSS, version 20.0). The frequencies and percentage were recorded and any associations with predisposing factors were statistically analyzed by t test. Out of hundred patients, 71 (71%) were found to have dry eyes (Pdry eye disease (Pdry eyes in males and females. Long duration was found to be related with increased occurrence of dry eyes (Pdry eyes. There is marked increase in frequency/ risk of developing dry eye disease in type 1 diabetes patients. Therefore, it is recommended to have periodic ophthalmic examination for type 1 diabetic patients.

  11. Surgical adhesives in ophthalmology: history and current trends.

    Science.gov (United States)

    Guhan, Samantha; Peng, Si-Liang; Janbatian, Hrag; Saadeh, Stephanie; Greenstein, Stephen; Al Bahrani, Faisal; Fadlallah, Ali; Yeh, Tsai-Chu; Melki, Samir A

    2018-03-26

    Tissue adhesives are gaining popularity in ophthalmology, as they could potentially reduce the complications associated with current surgical methods. An ideal tissue adhesive should have superior tensile strength, be non-toxic and anti-inflammatory, improve efficiency and be cost-effective. Both synthetic and biological glues are available. The primary synthetic glues include cyanoacrylate and the recently introduced polyethylene glycol (PEG) derivatives, while most biological glues are composed of fibrin. Cyanoacrylate has a high tensile strength, but rapidly polymerises upon contact with any fluid and has been associated with histotoxicity. Fibrin induces less toxic and inflammatory reactions, and its polymerisation time can be controlled. Tensile strength studies have shown that fibrin is not as strong as cyanoacrylate. While more research is needed, PEG variants currently appear to have the most promise. These glues are non-toxic, strong and time-effective. Through MEDLINE and internet searches, this paper presents a systematic review of the current applications of surgical adhesives to corneal, glaucoma, retinal, cataract and strabismus surgeries. Our review suggests that surgical adhesives have promise to reduce problems in current ophthalmic surgical procedures. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  12. Anaesthesiological aspects of thorax-diagnostic procedures in intensive-care units

    International Nuclear Information System (INIS)

    Schulte am Esch, J.

    1989-01-01

    Diagnostic procedures of the thorax in intensive-care units are conventional X-ray chest images, chest images by digital luminescence radiography, sonography and transoesophageal Doppler echocardiography. In addition to these bedside methods the stationary usable techniques, such as computed tomography, digital subtraction angiography and the seldom in intensive care patients used computed nuclear spin resonance tomography (NMR) are applicable. The selection of the above mentioned techniques depends on the availability and the quality of the methods as well as the qualifications of the involved staff. The diagnostic procedures of the chest must be arranged depending on the decision if patients have to be transported or not. In conclusion it can be stated that in spite of growing technical preconditions the availability of the methods in immobile patients and the diagnostic potency of the techniques have to be examined. (orig.) [de

  13. Sportsmen's Groin-Diagnostic Approach and Treatment With the Minimal Repair Technique: A Single-Center Uncontrolled Clinical Review.

    Science.gov (United States)

    Muschaweck, Ulrike; Berger, Luise Masami

    2010-05-01

    Sportsmen's groin, also called sports hernia and Gilmore groin, is one of the most frequent sports injuries in athletes and may place an athletic career at risk. It presents with acute or chronic groin pain exacerbated with physical activity. So far, there is little consensus regarding pathogenesis, diagnostic criteria, or treatment. There have been various attempts to explain the cause of the groin pain. The assumption is that a circumscribed weakness in the posterior wall of the inguinal canal, which leads to a localized bulge, induces a compression of the genital branch of the genitofemoral nerve, considered responsible for the symptoms. The authors developed an innovative open suture repair-the Minimal Repair technique-to fit the needs of professional athletes. With this technique, the circumscribed weakness of the posterior wall of the inguinal canal is repaired by an elastic suture; the compression on the nerve is abolished, and the cause of the pain is removed. In contrast with that of common open suture repairs, the defect of the posterior wall is not enlarged, the suture is nearly tension free, and the patient can return to full training and athletic activity within a shorter time. The outcome of patients undergoing operations with the Minimal Repair technique was compared with that of commonly used surgical procedures. THE FOLLOWING ADVANTAGES OF THE MINIMAL REPAIR TECHNIQUE WERE FOUND: no insertion of prosthetic mesh, no general anesthesia required, less traumatization, and lower risk of severe complications with equal or even faster convalescence. In 2009, a prospective cohort of 129 patients resumed training in 7 days and experienced complete pain relief in an average of 14 days. Professional athletes (67%) returned to full activity in 14 days (median). The Minimal Repair technique is an effective and safe way to treat sportsmen's groin.

  14. In-cylinder pressure-based direct techniques and time frequency analysis for combustion diagnostics in IC engines

    International Nuclear Information System (INIS)

    D’Ambrosio, S.; Ferrari, A.; Galleani, L.

    2015-01-01

    Highlights: • Direct pressure-based techniques have been applied successfully to spark-ignition engines. • The burned mass fraction of pressure-based techniques has been compared with that of 2- and 3-zone combustion models. • The time frequency analysis has been employed to simulate complex diesel combustion events. - Abstract: In-cylinder pressure measurement and analysis has historically been a key tool for off-line combustion diagnosis in internal combustion engines, but online applications for real-time condition monitoring and combustion management have recently become popular. The present investigation presents and compares different low computing-cost in-cylinder pressure based methods for the analyses of the main features of combustion, that is, the start of combustion, the end of combustion and the crankshaft angle that responds to half of the overall burned mass. The instantaneous pressure in the combustion chamber has been used as an input datum for the described analytical procedures and it has been measured by means of a standard piezoelectric transducer. Traditional pressure-based techniques have been shown to be able to predict the burned mass fraction time history more accurately in spark ignition engines than in diesel engines. The most suitable pressure-based techniques for both spark ignition and compression ignition engines have been chosen on the basis of the available experimental data. Time–frequency analysis has also been applied to the analysis of diesel combustion, which is richer in events than spark ignited combustion. Time frequency algorithms for the calculation of the mean instantaneous frequency are computationally efficient, allow the main events of the diesel combustion to be identified and provide the greatest benefits in the presence of multiple injection events. These algorithms can be optimized and applied to onboard diagnostics tools designed for real control, but can also be used as an advanced validation tool for

  15. A recommender system for medical imaging diagnostic.

    Science.gov (United States)

    Monteiro, Eriksson; Valente, Frederico; Costa, Carlos; Oliveira, José Luís

    2015-01-01

    The large volume of data captured daily in healthcare institutions is opening new and great perspectives about the best ways to use it towards improving clinical practice. In this paper we present a context-based recommender system to support medical imaging diagnostic. The system relies on data mining and context-based retrieval techniques to automatically lookup for relevant information that may help physicians in the diagnostic decision.

  16. Pulmonary carcinoma. Diagnostic and bronchoscopic treatment

    International Nuclear Information System (INIS)

    Caballero Duran, Hugo

    1997-01-01

    A historical recount of the bronchoscopy is made, from its beginnings 100 years ago, in a same way some techniques of diagnostic and treatment are mentioned, as the laser, fluorescence, cryotherapy, etc

  17. [Hypercoagulable workup in ophthalmology. When and what].

    Science.gov (United States)

    Muñoz-Negrete, F J; Casas-Lleras, P; Pérez-López, M; Rebolleda, G

    2009-07-01

    Most ophthalmologic disorders secondary to hypercoagulabe state are due to the confluence of congenital and adquired factors. A systematic workup is mandatory. Most of congenital coagulation disorders cause venous trombosis and are inherited autosomal dominantly. In order of frequency these are factor V Leiden mutation (activated protein C resistance), G20210A mutation of the prothrombin gen and protein C, protein S, and antithrombin III deficiencies. Sickle cell anemia can determine arerial and venous thrombosis. In relation with arterial occlusion, the markers most frequently involved are homcysteine fasting levels and the markers of antiphospholipid antibody syndrome. Both of them can also determine venous thrombosis. Several acquired factors can lead to hypoercoagulable state, especially hyperhomocysteinemia, antiphospholipid antibody syndrome, hepatic disease, alcohol and tobacco intake, oral contraceptives, immobilization, surgeries and malignancies. In central venous occlusion is only necessary to rule out hyperhomocysteinemia and antiphospholipid antibody syndrome in young patients without known risk factors. In central artery occlusion, hypercoagulable workup is only recommended for patients less than 50 years-old with unknown emboli source. In this cases protein C, protein S, and antithrombin III deficiencies, homocystein, sickle cell disease and antiphospholipid antibody syndrome will ruled out. In non arteritic ischemic optic neuropathy hypercoagulable work up is not necessary. In amaurosis fugax without known emboli source, it is recommended to rule out etiologies of arterial occlusion, especially antithrombin III deficiencies, homocystein, sickle cell disease and antiphospholipid antibody syndrome.

  18. Using Role-plays as an Empathy Education Tool for Ophthalmology Postgraduate.

    Science.gov (United States)

    Singh, Kirti; Bhattacharyya, Mainak; Veerwal, Vikas; Singh, Arshi

    2017-12-01

    To assess the role of an "empathy sensitizing module" (ESM) in ophthalmology postgraduates in promoting effective empathetic communication. Thirty-nine ophthalmology postgraduates were taught effective empathetic communication using specially designed module, comprising of five illustrative role-plays. We evaluated the impact of the training by (a) self-assessment of empathy quotient by residents using Jefferson Scale of Empathy (JSE scale) before and 6 weeks after ESM training and (b) nonparticipant observation (NPO) by trained faculty in real-life settings over the next 4 months. A peer-validated, self-designed checklist was used for NPO. The change in score was analyzed using Student's paired t -test. The faculty observed the use of empathy in real-life patient encounters of the trainees over the next 6 months. In addition, secondary qualitative data were collected and analyzed to assess the impact of the module on other stakeholders such as the role-playing undergraduate students and core faculty. Pretraining assessment revealed that concept of empathy during patient communication was understood by only 10% students. PostESM training, the self-rated mean empathy score, on JSE, significantly increased from 95.9 to 106.7 (of a maximum of 140). This was also confirmed by a significant improvement in externally rated empathy and soft skills scores (from 29.3 to 39.1; of a maximum of 55) using the NPO tool. Focus group discussion was done on the continued display of empathy by the trainees in real-life situation over 6 months of observation by the faculty. The group agreed that there was a gradual attrition of initial gain in empathy behavior over the observation period of 6 months. The spillover benefits of the training process were observed among the role-playing undergraduates as well. A thematic analysis of their reflections on the process revealed a substantial change with an improved understanding of effective communication. There is a definite scope for

  19. Diagnostic criteria in MR neurography

    International Nuclear Information System (INIS)

    Baeumer, P.

    2017-01-01

    Peripheral neuropathies are frequent and can mostly be correctly diagnosed by clinical examination and electrophysiology; however, diagnostically difficult cases are sometimes encountered especially with respect to precise localization of nerve lesions. Imaging of the peripheral nervous system has been shown to provide additional useful diagnostic information. In addition to the more widely available nerve sonography, magnetic resonance neurography (MRN) is the method of choice in diagnostically complex cases. The most important pulse sequence is a T2-weighted fat-saturated pulse sequence with high in-plane resolution and detects increased T2-weighted signals of nerve fascicles as a highly sensitive sign for nerve lesions. Further established diagnostic criteria are nerve caliber and, less commonly used, contrast agent uptake. The spatial pattern of nerve lesions aids in the diagnostic classification of neuropathies. Functional imaging techniques, such as diffusion tensor imaging (DTI) and nerve perfusion are currently under examination with respect to the clinical potential. If all other diagnostic methods, including clinical examination, electrophysiology and nerve sonography do not arrive at an unambiguous diagnosis of a peripheral neuropathy, MRN should be used. The special value of MRN is demonstrated particularly in complex nerve lesions, such as traumatic plexopathies and in partial fascicular neuropathies and many other indications. (orig.) [de

  20. Optical Coherence Tomography Angiography: Employing a Novel Technique for Investigation in Vogt-Koyanagi-Harada Disease.

    Science.gov (United States)

    Giannakouras, Panagiotis; Andreanos, Konstantinos; Giavi, Barbara; Diagourtas, Andreas

    2017-01-01

    To report a case of Vogt-Koyanagi-Harada (VKH) disease and describe the imaging findings by means of optical coherence tomography angiography (OCTA). Medical and ophthalmological history, ophthalmological examination, laboratory evaluation, B-scan ultrasonography, fluorescein and indocyanine angiography, and optical coherence tomography (OCT) were performed at baseline, as well as OCTA. A 50-year-old healthy female presented with decreased vision in both eyes. A Topcon DRI OCT Triton Plus swept source OCT system was used to visualize and evaluate the retinal and choroidal vascular plexus. Patchy and confluent dark areas in the superficial and deep retinal capillary plexus and choriocapillaris corresponded to areas of hypoperfusion, analyzed as areas of ischemia. VKH disease is characterized by ocular, neurological, and integumentary findings in its complete form. We present a case of incomplete disease in a 50-year-old female evaluated by means of OCTA which is a novel technique that provides depth-resolved images of the retina and choroidal microvasculature without dye injection that allows better visualization and detailed evaluation of the retinal and choroidal vascular plexus.

  1. The Resin-Embedded Cornea Prepared Via Rapid Processing Protocol : A Good Histomorphometric Target for Clinical Investigation in Ophthalmology and Optometry

    Science.gov (United States)

    Cheah, Pike See; Mohidin, Norhani; Mohd Ali, Bariah; Maung, Myint; Latif, Azian Abdul

    2008-01-01

    This study illustrates and quantifies the changes on corneal tissue between the paraffin-embedded and resin-embedded blocks and thus, selects a better target in investigational ophthalmology and optometry via light microscopy. Corneas of two cynomolgus monkeys (Macaca fascicularis) were used in this study. The formalin-fixed cornea was prepared in paraffin block via the conventional tissue processing protocol (4-day protocol) and stained with haematoxylin and eosin. The glutaraldehyde-fixed cornea was prepared in resin block via the rapid and modified tissue processing procedure (1.2-day protocol) and stained with toluidine blue. The paraffin-embedded sample exhibits various undesired tissue damage and artifact such as thinner epithelium (due to the substantial volumic extraction from the tissue), thicker stroma layer (due to the separation of lamellae and the presence of voids) and the distorted endothelium. In contrast, the resin-embedded corneal tissue has demonstrated satisfactory corneal ultrastructural preservation. The rapid and modified tissue processing method for preparing the resin-embedded is particularly beneficial to accelerate the microscopic evaluation in ophthalmology and optometry. PMID:22570589

  2. Evaluation of a simulation tool in ophthalmology: application in teaching funduscopy

    Directory of Open Access Journals (Sweden)

    Joice Elise Androwiki

    2015-02-01

    Full Text Available Purpose: The aim of this study was to evaluate the Eye Retinopathy Trainer® as a teaching tool for direct ophthalmoscopy examination by comparing it with the traditional method using volunteers. Methods: Fourth year medical students received training in direct ophthalmoscopy using a simulation tool and human volunteers. Ninety students were randomized into a Simulation Group or a Control Group by the inclusion or absence of the simulation model in classroom practice. Differences between the groups were analyzed using unpaired Student’s t-test. Results: The Simulation Group was superior to the Control Group, with 51.06% successful in performing fundus examination in both the anatomical model simulation and the human model in comparison with 21.15% in the Control Group. Conclusion: The Eye Retinopathy Trainer® appears to be an effective teaching tool for practice and improvement of ophthalmologic examination among fourth year medical students.

  3. Microwave imaging for plasma diagnostics and its applications

    International Nuclear Information System (INIS)

    Mase, A.; Kogi, Y.; Ito, N.

    2007-01-01

    Microwave to millimeter-wave diagnostic techniques such as interferometry, reflectometry, scattering, and radiometry have been powerful tools for diagnosing magnetically confined plasmas. Important plasma parameters were measured to clarify the physics issues such as stability, wave phenomena, and fluctuation-induced transport. Recent advances in microwave and millimeter-wave technology together with computer technology have enabled the development of advanced diagnostics for visualization of 2D and 3D structures of plasmas. Microwave/millimeter-wave imaging is expected to be one of the most promising diagnostic methods for this purpose. We report here on the representative microwave diagnostics and their industrial applications as well as application to magnetically-confined plasmas. (author)

  4. Planetary Transmission Diagnostics

    Science.gov (United States)

    Lewicki, David G. (Technical Monitor); Samuel, Paul D.; Conroy, Joseph K.; Pines, Darryll J.

    2004-01-01

    This report presents a methodology for detecting and diagnosing gear faults in the planetary stage of a helicopter transmission. This diagnostic technique is based on the constrained adaptive lifting algorithm. The lifting scheme, developed by Wim Sweldens of Bell Labs, is a time domain, prediction-error realization of the wavelet transform that allows for greater flexibility in the construction of wavelet bases. Classic lifting analyzes a given signal using wavelets derived from a single fundamental basis function. A number of researchers have proposed techniques for adding adaptivity to the lifting scheme, allowing the transform to choose from a set of fundamental bases the basis that best fits the signal. This characteristic is desirable for gear diagnostics as it allows the technique to tailor itself to a specific transmission by selecting a set of wavelets that best represent vibration signals obtained while the gearbox is operating under healthy-state conditions. However, constraints on certain basis characteristics are necessary to enhance the detection of local wave-form changes caused by certain types of gear damage. The proposed methodology analyzes individual tooth-mesh waveforms from a healthy-state gearbox vibration signal that was generated using the vibration separation (synchronous signal-averaging) algorithm. Each waveform is separated into analysis domains using zeros of its slope and curvature. The bases selected in each analysis domain are chosen to minimize the prediction error, and constrained to have the same-sign local slope and curvature as the original signal. The resulting set of bases is used to analyze future-state vibration signals and the lifting prediction error is inspected. The constraints allow the transform to effectively adapt to global amplitude changes, yielding small prediction errors. However, local wave-form changes associated with certain types of gear damage are poorly adapted, causing a significant change in the

  5. Knowledge based diagnostics in nuclear power plants

    International Nuclear Information System (INIS)

    Baldeweg, F.; Fiedler, U.; Weiss, F.P.; Werner, M.

    1987-01-01

    In this paper a special process diagnostic system (PDS) is presented. It must be seen as the result of a long term work on computerized process surveillance and control; it includes a model based system for noise analysis of mechanical vibrations, which has recently been enhanced by using of knowledge based technique (expert systems). The paper discusses the process diagnostic frame concept and emphasize the vibration analysis expert system

  6. The role of choline (Cho) in the diagnostics and differentiation of brain tumours with HMRS technique

    International Nuclear Information System (INIS)

    Sobiecka, B.; Urbanik, A.

    2009-01-01

    Background: The aim of the research was a comprehensive analysis of Cho concentration and Cho/Cr, NAA/Cho, NAA/Cho+Cr ratios for the purposes of the diagnostics and differentiation of brain tumours (the type of the pathological lesion in patients with brain tumours) with the use of HMRS technique. Material/Methods: The HMRS examinations were performed with the use of the MRI Signa Excite 1.5 T system, in PRESS technique (TR = 1500 ms, TE = 35 ms) and involved 100 patients with brain tumours (age range: 18 to 81 yrs, mean age 50.61). Spectra were taken from three different locations: tumour centre, the tumour edge and contralateral unchanged cerebral tissue. All patients underwent surgery followed by histopathological analysis, on the basis of which two groups were separated (benign tumours, malignant tumours - 50 cases each). Additionally, 30 healthy volunteers in the age of 20 to 79 years (mean age 40.8) were examined. Results: The comparison of the examined patients with the control group revealed significantly higher Cho concentrations in patients with brain tumours. The analysis of Cho concentration was also performed with consideration of the age factor (under and over 60 years of age). Significantly lower mean Cho concentrations were discovered in a group of patients under 60 years of age. The analysis of Cho concentrations and Cho/Cr ratios reveled statistical significance for two factors: voxel location factor and the type of the pathological lesion. The average of Cho concentration and Cho/Cr ratios were higher in the group of patients with malignant tumours. The highest Cho concentrations and Cho/Cr ratios were observed in the tumour centre. The relative NAA/Cho and NAA/Cho+Cr ratios were statistically significant when taking into consideration the voxel location factor only. The results received from contralateral normal cerebral tissue (the internal model) were compared with control group (the external model). Mean values of Cho concentration were

  7. Targeted Vision Function Goals and Use of Vision Resources in Ophthalmology Patients with Age-Related Macular Degeneration and Comorbid Depressive Symptoms

    Science.gov (United States)

    Casten, Robin; Rovner, Barry W.; Fontenot, Joseph L.

    2016-01-01

    Introduction: This study characterizes self-reported functional vision goals and the use of low vision resources (for example, services and devices) in ophthalmology clinic patients with age-related macular degeneration (AMD) and comorbid depressive symptoms. Methods: From July 2009 to February 2013, we assessed 188 consecutive patients (age 65+;…

  8. Office hysteroscopic-guided selective tubal chromopertubation: acceptability, feasibility and diagnostic accuracy of this new diagnostic non-invasive technique in infertile women.

    Science.gov (United States)

    Carta, Gaspare; Palermo, Patrizia; Pasquale, Chiara; Conte, Valeria; Pulcinella, Ruggero; Necozione, Stefano; Cofini, Vincenza; Patacchiola, Felice

    2018-06-01

    The aim of this study was to evaluate accuracy, tolerability and side effects of office hysteroscopic-guided chromoperturbations in infertile women without anaesthesia. Forty-nine infertile women underwent the procedure to evaluate tubal patency and the uterine cavity. Women with unilateral or bilateral tubal stenosis at hysteroscopy with chromoperturbation, and women with bilateral tubal patency who did not conceive during the period of six months, underwent laparoscopy with chromoperturbation. The results obtained from hysteroscopy and laparoscopy in the assessment of tubal patency were compared. Sensitivity, specificity, accuracy, positive-predictive value and negative-predictive value were used to describe diagnostic performance. Pain and tolerance were assessed during procedure using a visual analogue scale (VAS). Side effects or late complications and pregnancy rate were also recorded three and six months after the procedure. The specificity was 87.8% (95% CI: 73.80-95.90), sensitivity was 85.7% (95% CI 57.20-98.20), positive and negative predictive values were 70.6% (95% CI: 44.00-89) and 94.7% (95% CI: 82.30-99.40), respectively. Pregnancy rate (PR) within six months after performance of hysteroscopy with chromoperturbation was 27%. Office hysteroscopy-guided selective chromoperturbation in infertile patients is a valid technique to evaluate tubal patency and uterine cavity.

  9. Diagnostic imaging in medicine. 2nd ed

    Energy Technology Data Exchange (ETDEWEB)

    Reba, R C; Goodenough, D J; Davidson, H F

    1984-01-01

    This book describes to practitioners the evolutionary progression of new non-invasive diagnostic imaging techniques. The utility of the procedures is also described in a series of state-of-the-art lectures given by outstanding international clinical investigators from NATO countries. Subjects of the papers include the following: advances in source and detector technology, acoustical imaging, NMR and microwave imaging, positron and single photon emission tomography, digital radiography and image processing and display techniques. Fundamental papers describing the theory of non-invasive procedures are included along with papers describing clinical examinations. Examples of utility and studies of diseases of the abdomen and pelvis, heart and lung, and central nervous system are included. Cost-effective and cost-benefit assessment of the new high technology procedures, as well as the use of diagnostic imaging techniques in developing countries are also presented. An index of leading topics completes the volume.

  10. Diagnostic accuracy of magnetic resonance imaging techniques for treatment response evaluation in patients with high-grade glioma, a systematic review and meta-analysis

    Energy Technology Data Exchange (ETDEWEB)

    Dijken, Bart R.J. van [University of Groningen, University Medical Center Groningen Department of Radiology, Groningen (Netherlands); Laar, Peter Jan van; Hoorn, Anouk van der [University of Groningen, University Medical Center Groningen Department of Radiology, Groningen (Netherlands); University of Groningen, University Medical Center Groningen, Center for Medical Imaging-North East Netherlands, Groningen (Netherlands); Holtman, Gea A. [University of Groningen, University Medical Center Groningen, Department of General Practice, Groningen (Netherlands)

    2017-10-15

    Treatment response assessment in high-grade gliomas uses contrast enhanced T1-weighted MRI, but is unreliable. Novel advanced MRI techniques have been studied, but the accuracy is not well known. Therefore, we performed a systematic meta-analysis to assess the diagnostic accuracy of anatomical and advanced MRI for treatment response in high-grade gliomas. Databases were searched systematically. Study selection and data extraction were done by two authors independently. Meta-analysis was performed using a bivariate random effects model when ≥5 studies were included. Anatomical MRI (five studies, 166 patients) showed a pooled sensitivity and specificity of 68% (95%CI 51-81) and 77% (45-93), respectively. Pooled apparent diffusion coefficients (seven studies, 204 patients) demonstrated a sensitivity of 71% (60-80) and specificity of 87% (77-93). DSC-perfusion (18 studies, 708 patients) sensitivity was 87% (82-91) with a specificity of 86% (77-91). DCE-perfusion (five studies, 207 patients) sensitivity was 92% (73-98) and specificity was 85% (76-92). The sensitivity of spectroscopy (nine studies, 203 patients) was 91% (79-97) and specificity was 95% (65-99). Advanced techniques showed higher diagnostic accuracy than anatomical MRI, the highest for spectroscopy, supporting the use in treatment response assessment in high-grade gliomas. (orig.)

  11. Diagnostics for induction accelerators

    International Nuclear Information System (INIS)

    Fessenden, T.J.

    1997-01-01

    The induction accelerator was conceived by N. C. Christofilos and first realized as the Astron accelerator that operated at Lawrence Livermore National Laboratory (LLNL) from the early 1960s to the end of 1975. This accelerator generated electron beams at energies near 6 MeV with typical currents of 600 Amperes in 400-ns pulses. The Advanced Test Accelerator (ATA) built at Livermore close-quote s Site 300 produced 10,000-Ampere beams with pulse widths of 70 ns at energies approaching 50 MeV. Several other electron and ion induction accelerators have been fabricated at LLNL and Lawrence Berkeley National Laboratory (LBNL). This paper reviews the principal diagnostics developed through efforts by scientists at both laboratories for measuring the current, position, energy, and emittance of beams generated by these high-current, short-pulse accelerators. Many of these diagnostics are closely related to those developed for other accelerators. However, the very fast and intense current pulses often require special diagnostic techniques and considerations. The physics and design of the more unique diagnostics developed for electron induction accelerators are presented and discussed in detail. copyright 1997 American Institute of Physics

  12. Mini-FLOTAC, an innovative direct diagnostic technique for intestinal parasitic infections: experience from the field.

    Science.gov (United States)

    Barda, Beatrice Divina; Rinaldi, Laura; Ianniello, Davide; Zepherine, Henry; Salvo, Fulvio; Sadutshang, Tsetan; Cringoli, Giuseppe; Clementi, Massimo; Albonico, Marco

    2013-01-01

    Soil-transmitted helminths and intestinal protozoa infection are widespread in developing countries, yet an accurate diagnosis is rarely performed. The aim of this study was to evaluate the recently developed mini-FLOTAC method and to compare with currently more widely used techniques for the diagnosis of intestinal parasitic infections in different settings. The study was carried out in Dharamsala, Himachal Pradesh, India, and in Bukumbi, Tanzania. A total of 180 pupils from two primary schools had their stool analyzed (n = 80 in Dharamsala and n = 100 in Bukumbi) for intestinal parasitic infections with three diagnostic methods: direct fecal smear, formol-ether concentration method (FECM) and mini-FLOTAC. Overall, 72% of the pupils were positive for any intestinal parasitic infection, 24% carried dual infections and 11% three infections or more. The most frequently encountered intestinal parasites were Entamoeba coli, Entamoeba histolytica/dispar, Giardia intestinalis, hookworm, (and Schistosoma mansoni, in Tanzania). Statistically significant differences were found in the detection of parasitic infections among the three methods: mini-FLOTAC was the most sensitive method for helminth infections (90% mini-FLOTAC, 60% FECM, and 30% direct fecal smear), whereas FECM was most sensitive for intestinal protozoa infections (88% FECM, 70% direct fecal smear, and 68% mini-FLOTAC). We present the first experiences with the mini-FLOTAC for the diagnosis of intestinal helminths and protozoa. Our results suggest that it is a valid, sensitive and potentially low-cost alternative technique that could be used in resource-limited settings--particularly for helminth diagnosis.

  13. SU-F-T-427: Utilization and Evaluation of Diagnostic CT Imaging with MAR Technique for Radiation Therapy Treatment Planning

    International Nuclear Information System (INIS)

    Xu, M; Foster, R; Parks, H; Pankuch, M

    2016-01-01

    Purpose: The objective was to utilize and evaluate diagnostic CT-MAR technique for radiation therapy treatment planning. Methods: A Toshiba-diagnostic-CT acquisition with SEMAR(Single-energy-MAR)-algorism was performed to make the metal-artifact-reduction (MAR) for patient treatment planning. CT-imaging datasets with and without SEMAR were taken on a Catphan-phantom. Two sets of CT-numbers were calibrated with the relative electron densities (RED). A tissue characterization phantom with Gammex various simulating material rods was used to establish the relationship between known REDs and corresponding CT-numbers. A GE-CT-sim acquisition was taken on the Catphan for comparison. A patient with bilateral hip arthroplasty was scanned in the radiotherapy CT-sim and the diagnostic SEMAR-CT on a flat panel. The derived SEMAR images were used as a primary CT dataset to create contours for the target, critical-structures, and for planning. A deformable registration was performed with VelocityAI to track voxel changes between SEMAR and CT-sim images. The SEMAR-CT images with minimal artifacts and high quality of geometrical and spatial integrity were employed for a treatment plan. Treatment-plans were evaluated based on deformable registration of SEMAR-CT and CT-sim dataset with assigned CT-numbers in the metal artifact regions in Eclipse v11 TPS. Results: The RED and CT-number relationships were consistent for the datasets in CT-sim and CT’s with and without SEMAR. SEMAR datasets with high image quality were used for PTV and organ delineation in the treatment planning process. For dose distribution to the PTV through the DVH analysis, the plan using CT-sim with the assigned CT-number showed a good agreement to those on deformable CT-SEMAR. Conclusion: A diagnostic-CT with MAR-algorithm can be utilized for radiotherapy treatment planning with CT-number calibrated to the RED. Treatment planning comparison and DVH shows a good agreement in the PTV and critical organs between

  14. Metabolomics for laboratory diagnostics.

    Science.gov (United States)

    Bujak, Renata; Struck-Lewicka, Wiktoria; Markuszewski, Michał J; Kaliszan, Roman

    2015-09-10

    Metabolomics is an emerging approach in a systems biology field. Due to continuous development in advanced analytical techniques and in bioinformatics, metabolomics has been extensively applied as a novel, holistic diagnostic tool in clinical and biomedical studies. Metabolome's measurement, as a chemical reflection of a current phenotype of a particular biological system, is nowadays frequently implemented to understand pathophysiological processes involved in disease progression as well as to search for new diagnostic or prognostic biomarkers of various organism's disorders. In this review, we discussed the research strategies and analytical platforms commonly applied in the metabolomics studies. The applications of the metabolomics in laboratory diagnostics in the last 5 years were also reviewed according to the type of biological sample used in the metabolome's analysis. We also discussed some limitations and further improvements which should be considered taking in mind potential applications of metabolomic research and practice. Copyright © 2014 Elsevier B.V. All rights reserved.

  15. Diagnostics for PLX-alpha

    Science.gov (United States)

    Gilmore, Mark; Hsu, Scott

    2015-11-01

    The goal of the Plasma Liner eXperiment PLX-alpha at Los Alamos National Laboratory is to establish the viability of creating a spherically imploding plasma liner for MIF and HED applications, using a spherical array of supersonic plasma jets launched by innovative contoured-gap coaxial plasma guns. PLX- α experiments will focus in particular on establishing the ram pressure and uniformity scalings of partial and fully spherical plasma liners. In order to characterize these parameters experimentally, a suite of diagnostics is planned, including multi-camera fast imaging, a 16-channel visible interferometer (upgraded from 8 channels) with reconfigurable, fiber-coupled front end, and visible and VUV high-resolution and survey spectroscopy. Tomographic reconstruction and data fusion techniques will be used in conjunction with interferometry, imaging, and synthetic diagnostics from modeling to characterize liner uniformity in 3D. Diagnostic and data analysis design, implementation, and status will be presented. Supported by the Advanced Research Projects Agency - Energy - U.S. Department of Energy.

  16. The Development of a Post-Baccalaureate Certificate Program in Molecular Diagnostics

    Science.gov (United States)

    Williams, Gail S.; Brown, Judith D.; Keagle, Martha B.

    2000-01-01

    A post-baccalaureate certificate program in diagnostic molecular sciences was created in 1995 by the Diagnostic Genetic Sciences Program in the School of Allied Health at the University of Connecticut. The required on-campus lecture and laboratory courses include basic laboratory techniques, health care issues, cell biology, immunology, human genetics, research, management, and molecular diagnostic techniques and laboratory in molecular diagnostics. These courses precede a 6-month, full-time practicum at an affiliated full-service molecular laboratory. The practicum includes amplification and blotting methods, a research project, and a choice of specialized electives including DNA sequencing, mutagenesis, in situ hybridization methods, or molecular diagnostic applications in microbiology. Graduates of the program are immediately eligible to sit for the National Credentialing Agency examination in molecular biology to obtain the credential Clinical Laboratory Specialist in Molecular Biology (CLSp(MB). This description of the University of Connecticut program may assist other laboratory science programs in creating similar curricula. PMID:11232107

  17. Essentials of diagnostic and interventional angiographic technique

    International Nuclear Information System (INIS)

    Gerlock, A.J.; Mirfakhraee, M.

    1985-01-01

    This volume presents coverage of basic angiographic techniques and shows how to get to the point of taking the angiogram, and tells how to avoid pitfalls. Particularly valuable is the information on how to get out of trouble if an error is made while manipulating the catheter

  18. Inertial confinement fusion diagnostics

    International Nuclear Information System (INIS)

    Coleman, L.W.

    1986-10-01

    The concept and goals of ICF will be briefly reviewed and the new 100 kJ class Nova laser facility will be described. Experimental results obtained to date with Nova will be summarized, and the discussions of diagnostics will use examples on the present capabilities of Nova and new developments that are underway. The classes of diagnostic systems to be discussed fall into three basic categories: optical, x-ray, and particle. Examples of highly space resolved, time resolved, and spectrally resolved techniques as well as schemes involving combinations of these capabilities will be presented. A brief summary of the sophisticated acquisition and analysis system in use for Nova data will be provided

  19. Gonad shielding in diagnostic radiology

    International Nuclear Information System (INIS)

    1975-06-01

    The use of gonad shielding is an important radiation protection technique, intended to reduce unnecessary x-ray exposure of the gonads of patients from diagnostic x-ray procedures. This pamphlet will provide physicians and radiologic technologists with information which will aid their appropriate use of gonad shielding

  20. Characterization and Diagnostics for Photovoltaic Modules and Arrays

    DEFF Research Database (Denmark)

    Spataru, Sergiu

    part of this work were developed based on two well-known module characterization techniques, namely current-voltage (I-V) characterization, and electroluminescence imaging. he I-V based module diagnostic methods were developed by combining the strengths of light I-V and dark I-V characterization......, characterization and diagnostic methods are increasingly important in identifying and understanding the failures and degradation modes affecting PV modules and arrays, as well as developing relevant tools and tests for assessing the reliability and lifetime of PV modules. This thesis investigates diagnostic...... methods for characterizing and detecting degradation modes in crystalline silicon photovoltaic modules and arrays, and is structured into two parts. The first part of this work is focused on developing PV module characterization and diagnostic methods for use in module diagnostics and failure...