WorldWideScience

Sample records for diagnostic techniques ophthalmological

  1. Diagnostic imaging in ophthalmology

    International Nuclear Information System (INIS)

    Gonzalez, C.F.; Becker, M.H.; Flanagan, J.C.

    1986-01-01

    There are three sections in the book. The first section is a discussion of imaging techniques, which includes plain film radiography and multidirectional tomography of the orbit, computed tomography (CT) of the orbit and its use in the evaluation of ocular motility disorders, ultrasonography of the eye and orbit, investigation of the orbit by contrast techniques (which includes a brief review of angiography), the lachrimal drainage system, foreign body localization, and magnetic resonance imaging of the eye and orbit. There is extensive discussion of CT throughout the book. The second section is devoted to the role of these imaging methods in the evaluation of ophthalmic disorders. A discussion of congenital anomalies is useful for those centers that are exposed to unusual congenital anomalies and syndromes. Also included is evaluation of exophthalmous and thyroid ophthamalopathy, orbital tumors, lesions involving the visual pathways, CT assessment of paraorbital pathology (including basal and squamous cell tumors of the face), infection of the orbit, and orbital trauma. The third section is an overview of radiation therapy and malignant intraoccular tumors

  2. Diagnostic techniques

    International Nuclear Information System (INIS)

    Berquist, T.H.; Bender, C.E.; James, E.M.; Brown, M.L.; McLeod, R.A.; Broderick, D.F.; Welch, T.J.

    1989-01-01

    Proper application of imaging procedures is essential to obtain needed information for diagnosis and therapy planning in patients with suspected foot and/or ankle pathology. This paper provides basic background data for the numerous imaging techniques

  3. TECHNIQUES OF EVALUATION OF HEMOGLOBIN OXYGEN SATURATION IN CLINICAL OPHTHALMOLOGY

    Directory of Open Access Journals (Sweden)

    S. Yu. Petrov

    2016-01-01

    Full Text Available Oxygen content in body fluids and tissues is an important indicator of life support functions. A number of ocular pathologies, e.g. glaucoma, are of presumable vascular origin which means altered blood supply and oxygen circulation. Most oxygen is transported in the blood in the association with hemoglobin. When passing through the capillaries, hemoglobin releases oxygen, converting from oxygenated form to deoxygenated form. This process is accompanied by the changes in spectral characteristics of hemoglobin which result in different colors of arterial and venous blood. Photometric technique for the measurement of oxygen saturation in blood is based on the differences in light absorption by different forms of hemoglobin. The measurement of saturation is called oximetry. Pulse oximetry with assessment of tissue oxygenation is the most commonly used method in medicine. The degree of hemoglobin oxygen saturation in the eye blood vessels is the most accessible for noninvasive studies during ophthalmoscopy and informative. Numerous studies showed the importance of this parameter for the diagnosis of retinopathy of various genesis, metabolic status analysis in hyperglycemia, diagnosis and control of treatment of glaucoma and other diseases involving alterations in eye blood supply. The specific method for evaluation of oxygen concentration is the measurement of pressure of oxygen dissolved in the blood, i.e. partial pressure of oxygen. In ophthalmological practice, this parameter is measured in anterior chamber fluid evaluating oxygen level for several ophthalmopathies including different forms of glaucoma, for instillations of hypotensive eye drops as well as in vitreous body near to the optic disc under various levels of intraocular pressure. Currently, monitoring of oxygen saturation in retinal blood vessels, i.e. retinal oximetry, is well developed. This technique is based on the assessment of light absorption by blood depending on

  4. LEAN SIX SIGMA TECHNIQUES TO IMPROVE OPHTHALMOLOGY CLINIC EFFICIENCY.

    Science.gov (United States)

    Ciulla, Thomas A; Tatikonda, Mohan V; ElMaraghi, Yehya A; Hussain, Rehan M; Hill, Amanda L; Clary, Julie M; Hattab, Eyas

    2017-07-18

    Ophthalmologists serve an increasing volume of a growing elderly population undergoing increasingly complex outpatient medical care, including extensive diagnostic testing and treatment. The resulting prolonged patient visit times ("patient flow times") limit quality, patient and employee satisfaction, and represent waste. Lean Six Sigma process improvement was used in a vitreoretinal practice to decrease patient flow time, demonstrating that this approach can yield significant improvement in health care. Process flow maps were created to determine the most common care pathways within clinic. Three months' visits from the electronic medical record system, which tracks patient task times at each process step in the office were collected. Care tasks and care pathways consuming the greatest time and variation were identified and modified. Follow-up analysis from 6 weeks' visits was conducted to assess improvement. Nearly all patients took one of five paths through the office. Patient flow was redesigned to reduce waiting room time by having staff members immediately start patients into one of those five paths; staffing was adjusted to address high demand tasks, and scheduling was optimized around derived predictors of patient flow times. Follow-up analysis revealed a statistically significant decline in mean patient flow time by 18% and inpatient flow time SD by 4.6%. Patient and employee satisfaction scores improved. Manufacturing industry techniques, such as Lean and Six Sigma, can be used to improve patient care, minimize waste, and enhance patient and staff satisfaction in outpatient clinics.

  5. The use of ultrasonography in pediatric ophthalmology - diagnostics of ophthalmic disorders in newborns and infants

    International Nuclear Information System (INIS)

    Modrzejewska, M.; Karczewicz, D.; Wilk, G.

    2006-01-01

    Ultrasonographic (US) examinations in ophthalmology play a major role as one of the additional examination modes in the diagnostics of orbital diseases, and in cases of changes of a vascular origin it is useful in the evaluation of blood flow velocity. The special value of this examination in the assessment of the opaque optical structures on the fundus of the eye is emphasized. The aim of the study was 1) to present the ultrasonographic images and the efficacy of the method in the evaluation of some congenital and acquired bulbar diseases and 2) on the bases of the advantages of the examination, to determine whether ultrasonography could be included as a screening method in the diagnostics of preterm infants as well as a method of choice in term infants with ophthalmologic diseases. One thousand sixty-two children between the ages of 3 weeks to 12 months, of whom 1135 were preterm and 27 term infants, with ophthalmologic changes were examined. A real-time ultrasonographic apparatus with color Doppler (5-7.5 MHz sectoral and 7.5-10 MHz linear transducers). The US examinations of preterm infants were conducted four times and in term infants twice. In 105 children (8.99%) and in 184 eyes, premature retinopathy, intra-bulbar tumors, retinal ablation, posttraumatic changes, inflammatory processes in the posterior chamber of the eyeball, and congenital anomalies of the bulbar structures were diagnosed. Bulbar ultrasonography, being a safe, quick, and efficient examination, should be included as an additional screening method in preterm infants. Ultrasonography with color Doppler is an efficient method of choice for diagnosing problematic diseases of the eyeballs of infants. (author)

  6. Indications for and techniques of keratoplasty at Vietnam National Institute of Ophthalmology

    Directory of Open Access Journals (Sweden)

    Pham Ngoc Dong

    2016-03-01

    Full Text Available AIM: To report the indications for and techniques of corneal transplantation at Vietnam National Institute of Ophthalmology (VNIO over a period of 12y (2002-2013. METHODS: Records of patients who had undergone corneal transplantation at VNIO from January 1, 2002 to January 1, 2014 were reviewed to determine the indication for and type of corneal transplant performed. Patient age, gender, indication for corneal transplantation and surgical technique were recorded and analyzed. RESULTS: Corneal transplantation were underwent in 1390 eyes of 1278 patients with a mean age of 44.9±18.1y during the period under review. The most common indication was infectious corneal ulcer (n=670; 48.2%, followed by corneal scar (n=333, 24.0%, corneal dystrophy (n=138, 9.9% and failed graft (n=112, 8.1%. Nearly all procedures performed were penetrating keratoplasty (n=1300, 93.5%, with a few lamellar keratoplasty procedures performed: lamellar keratoplasty (n=52, 3.7%, Descemet’s stripping automated endothelial keratoplasty (n=27, 1.9% and deep anterior lamellar keratoplasty (n=11, 0.8%. CONCLUSION: While the most common indication for keratoplasty was infectious keratitis, nearly all indications for corneal transplantation were managed with penetrating keratoplasty. However, lamellar keratoplasty techniques, including deep anterior lamellar keratoplasty and Descemet’s stripping automated endothelial keratoplasty, are being performed with increasing frequency for isolated stromal and endothelial disorders, respectively.

  7. International patenting in ophthalmology: An analysis of its structure and relevance for the development of drugs and diagnostics

    Directory of Open Access Journals (Sweden)

    Hermann AM Mucke

    2008-10-01

    Full Text Available Hermann AM Mucke, Peter Mucke, Eva MuckeHM Pharma Consultancy, Vienna, AustriaAbstract: While investigative ophthalmologists access peer-reviewed journals as part of their daily routine, and while they regularly visit scientific congresses, they rarely peruse patent documents as an information source. Among the reasons for this negligence are the incompatibility of patent search algorithms with those known from journal databases, a legalistic and frequently redundant language, and misconceptions about the nature of the patenting system. Here we present key data and analyses from the ophthalmology module of a patent database system that we are developing to address some of these problems. We show that international patent applications consistently reflect developer interest in the ocular drug and diagnostics field; that they are technically focused lead indicators of developments that frequently feature in peer-reviewed patenting only much later; and that patenting targets are well aligned with the unmet therapeutic needs of populations in industrialized countries. Most applications (74%–78% in years since 2006 are supported with experimental data, and most (on average, 80%–90% faced at least one objection to patentability during their initial stage of examination. In contrast to the peer-reviewed scenery that is highly diverse, the corresponding patenting arena shows a pronounced focus on the United States.Keywords: ophthalmology, eye diseases, iontophoresis, intellectual property, patents as topic, bibliographic databases

  8. Reported estimates of diagnostic accuracy in ophthalmology conference abstracts were not associated with full-text publication.

    Science.gov (United States)

    Korevaar, Daniël A; Cohen, Jérémie F; Spijker, René; Saldanha, Ian J; Dickersin, Kay; Virgili, Gianni; Hooft, Lotty; Bossuyt, Patrick M M

    2016-11-01

    To assess whether conference abstracts that report higher estimates of diagnostic accuracy are more likely to reach full-text publication in a peer-reviewed journal. We identified abstracts describing diagnostic accuracy studies, presented between 2007 and 2010 at the Association for Research in Vision and Ophthalmology (ARVO) Annual Meeting. We extracted reported estimates of sensitivity, specificity, area under the receiver operating characteristic curve (AUC), and diagnostic odds ratio (DOR). Between May and July 2015, we searched MEDLINE and EMBASE to identify corresponding full-text publications; if needed, we contacted abstract authors. Cox regression was performed to estimate associations with full-text publication, where sensitivity, specificity, and AUC were logit transformed, and DOR was log transformed. A full-text publication was found for 226/399 (57%) included abstracts. There was no association between reported estimates of sensitivity and full-text publication (hazard ratio [HR] 1.09 [95% confidence interval {CI} 0.98, 1.22]). The same applied to specificity (HR 1.00 [95% CI 0.88, 1.14]), AUC (HR 0.91 [95% CI 0.75, 1.09]), and DOR (HR 1.01 [95% CI 0.94, 1.09]). Almost half of the ARVO conference abstracts describing diagnostic accuracy studies did not reach full-text publication. Studies in abstracts that mentioned higher accuracy estimates were not more likely to be reported in a full-text publication. Copyright © 2016 Elsevier Inc. All rights reserved.

  9. Simplified diagnostic coding sheet for computerized data storage and analysis in ophthalmology.

    Science.gov (United States)

    Tauber, J; Lahav, M

    1987-11-01

    A review of currently-available diagnostic coding systems revealed that most are either too abbreviated or too detailed. We have compiled a simplified diagnostic coding sheet based on the International Coding and Diagnosis (ICD-9), which is both complete and easy to use in a general practice. The information is transferred to a computer, which uses the relevant (ICD-9) diagnoses as database and can be retrieved later for display of patients' problems or analysis of clinical data.

  10. Novel Nonlinear Laser Diagnostic Techniques

    Science.gov (United States)

    1993-07-01

    a thermometric probe of reactive flows. Since the two-photon pump laser couples a Doppler broadened ground state velocity distribution to the excited...rism, and passed unfocused into an aluminum cell con- in frequency space. Regions for line fitting are found by taining 99% pure NO. The gas mixture...of ASE as a More recently, ASE has prompted interest as an thermometric probe of combustion environments optical diagnostic of combustion environments

  11. Mammography: Technique and diagnostic accuracy

    International Nuclear Information System (INIS)

    Kim, Chung Ja; Bahk, Yong Whee; Lee, Don Young

    1974-01-01

    Mammography is now in world wide use, But this has received rather scanty attention in Korea. The purposes of the present communication are twofold: (1) Detailing of technical and photographic aspects of mam in ography and (2) an assessment of its diagnostic accuracy as experienced by us. The clinical materials consisted of 88 cases of mammography performed at the Department of Radiology, St. Mary's Hospital, Catholic Medical College during the 2 years-period from April 1972. We used nonscreen type mammographic or industrial fine- grain films, and a special mammographic device that can be attached to any of the ordinary radiographic machine. Technical factors are shown in Table II. Of 88 cases 19 were operated on or biopsied. There were 7 cases of carcinoma. 8 cases of inflammatory diseases, and 4 cases of benign tumor. Mammographic diagnosis was correct in 85.7% of carcinoma and 87.5% of inflammatory diseases. One misdiagnosis of 7 cases of carcinoma was turned out to be cystosarcoma phylloides. Of 4 cases of benign tumors 2 were correctly diagnosed, and the other 2 mistaken for either inflammatory disease or simple lactating breast. However, none of the benign conditions were diagnosed as malignant process. We found that nonscreen type mammographic or industrial fine-grain films, and hand-processing were necessary in obtaining the mammograms of desirable quality

  12. Progress in diagnostic techniques for sc cavities

    International Nuclear Information System (INIS)

    Reece, C.E.

    1988-01-01

    While routinely achieved performance characteristics of superconducting cavities have now reached a level which makes them useful in large scale applications, achieving this level has come only through the knowledge gained by systematic studies of performance limiting phenomena. Despite the very real progress that has been made, the routine performance of superconducting cavities still falls far short of both the theoretical expectations and the performance of a few exception examples. It is the task of systematically applied diagnostic techniques to reveal additional information concerning the response of superconducting surfaces to applied RF fields. Here recent developments in diagnostic techniques are discussed. 18 references, 12 figures

  13. Alternative diagnostic technique for carpal tunnel syndrome

    International Nuclear Information System (INIS)

    Hayakawa, Katsuhiko; Nakane, Takashi; Kobayashi, Shigeru; Shibata, Kunio

    2002-01-01

    Compressive and entrapment neuropathies are common clinical syndromes characterized by neurologic deficits due to mechanical or dynamic compression of peripheral nerves. However, the definitive diagnosis based on clinical symptoms alone is difficult in many cases, and the electrophysiological diagnostic method is solely used as a supplementary diagnostic method at present. As a new diagnostic method for entrapment neuropathy, the present study investigated the usefulness of gadolinium-enhanced MRI in carpal tunnel syndrome. On enhanced MRI of idiopathic carpal tunnel syndrome, contrast-enhancement in the median nerve was found in 30 of 34 hands (88.2%). Enhanced MRI allows to visualize intraneural edema in the nerve easily on the naked eye. Therefore, this technique supplied useful information for making definitive diagnosis and is promising as a non-invasive diagnostic method for entrapment neuropathy. (author)

  14. Alternative diagnostic technique for carpal tunnel syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Hayakawa, Katsuhiko; Nakane, Takashi [Aiko Orthopaedic Hospital, Nagoya (Japan); Kobayashi, Shigeru; Shibata, Kunio [Fujita Health Univ., Toyoake, Aichi (Japan). School of Medicine

    2002-10-01

    Compressive and entrapment neuropathies are common clinical syndromes characterized by neurologic deficits due to mechanical or dynamic compression of peripheral nerves. However, the definitive diagnosis based on clinical symptoms alone is difficult in many cases, and the electrophysiological diagnostic method is solely used as a supplementary diagnostic method at present. As a new diagnostic method for entrapment neuropathy, the present study investigated the usefulness of gadolinium-enhanced MRI in carpal tunnel syndrome. On enhanced MRI of idiopathic carpal tunnel syndrome, contrast-enhancement in the median nerve was found in 30 of 34 hands (88.2%). Enhanced MRI allows to visualize intraneural edema in the nerve easily on the naked eye. Therefore, this technique supplied useful information for making definitive diagnosis and is promising as a non-invasive diagnostic method for entrapment neuropathy. (author)

  15. A REVIEW ON DIAGNOSTIC TECHNIQUES FOR BRUCELLOSIS

    African Journals Online (AJOL)

    User

    2014-01-01

    Jan 1, 2014 ... Brucellosis presents with many clinical manifestation that make its diagnosis a difficult task. Ever since the report of the first serologic test for brucellosis, a definitive diagnostic technique has been actively pursued. The most widely used methods of diagnosis are based on serology, which measures the.

  16. Adaptive techniques for diagnostics of vibrating structures

    International Nuclear Information System (INIS)

    Skormin, V.A.; Sankar, S.

    1983-01-01

    An adaptive diagnostic procedure for vibrating structures based on correspondence between current estimates of stiffness matrix and structure status is proposed. Procedure employs adaptive mathematical description of the vibrating structure in frequency domain, statistical techniques for detection and location of changes of structure properties, 'recognition' and prediction of defects. (orig.)

  17. Nordic research in ophthalmology

    DEFF Research Database (Denmark)

    Stefánsson, Einar; Zetterström, Charlotta; Ehlers, Niels

    2003-01-01

    Ophthalmology, eye research, cornea, catarcat, paediatric ophthalmology, glaucoma, diabetic eye disease, age-related macular degeneration, ophthalmic oncology......Ophthalmology, eye research, cornea, catarcat, paediatric ophthalmology, glaucoma, diabetic eye disease, age-related macular degeneration, ophthalmic oncology...

  18. Technique of infrared synchrotron acceleration diagnostics

    International Nuclear Information System (INIS)

    Mal'tsev, A.A.; Mal'tsev, M.A.

    1997-01-01

    Techniques of measuring of current and geometric parameters and evaluating of energy parameters of the ring bunch of relativistic low-energy electrons have been presented. They have been based on using the synchrotron radiation effect in its infrared spectral part. Fast infrared detectors have provided radiation detection in the spectral range Δλ ≅ 0.3-45 μm. The descriptions of some data monitoring and measuring systems developed in JINR for the realization of techniques of the infrared synchrotron acceleration diagnostics have been given. Infrared optics elements specially developed have been used in these systems

  19. Therapeutic application of lasers in ophthalmology

    International Nuclear Information System (INIS)

    Misiuk-Hojlo, M.; Krzyzanowska-Berkowska, P.; Hill-Bator, A.

    2007-01-01

    Lasers have found application in diverse branches of medicine. In ophthalmology, laser technology has various therapeutic and diagnostic applications. The purpose of this article is to review the major therapeutic applications of lasers in different eye disorders. The effects of lasers on biological tissues and different laser techniques as well as the indications for laser therapy in various parts of the eye are discussed. Lasers are used to treat glaucoma and many vascular disorders of the retina. Laser treatment may be useful in preventing the development of neovascularization in diabetic retinopathy, BRVO, or CRVO. Laser techniques are also available for the treatment of the exudative form of age-related macular degeneration (AMD) and some malignant and benign intraocular tumors and in retina abnormalities which predispose to rhegmatogenous retinal detachment. Corneal laser surgery is the most frequently applied laser procedure in ophthalmology. PRK, LASIK, and LASEK are used to correct errors in vision such as myopia, hyperopia, and astigmatism. Laser photocoagulation is also helpful in cataract surgery. Nowadays, lasers have become so universal that it is difficult to imagine ophthalmology without them. We are still witnessing rapid advances in the development of laser techniques, especially in plastic surgery, cataract extraction, and ocular imaging. (authors)

  20. Dental diagnostics using optical coherence techniques

    Energy Technology Data Exchange (ETDEWEB)

    Nathel, H. [Lawrence Livermore National Lab., CA (United States); Colston, B. [Univ. of California, San Francisco, CA (United States); Armitage, G. [Univ. of California, Davis, CA (United States)] [and others

    1994-11-15

    Optical radiation can be used for diagnostic purposes in oral medicine. However, due to the turbid, amorphous, and inhomogeneous nature of dental tissue conventional techniques used to transilluminate materials are not well suited to dental tissues. Optical coherence techniques either in the time- of frequency-domain offer the capabilities of discriminating scattered from unscattered light, thus allowing for imaging through turbid tissue. Currently, using optical time-domain reflectometry we are able to discriminate specular from diffuse reflections occurring at tissue boundaries. We have determined the specular reflectivity of enamel and dentin to be approximately 6.6 x 10{sup -5} and 1.3 x 10{sup -6}, respectively. Implications to periodontal imaging will be discussed.

  1. Neuro-ophthalmology update.

    Science.gov (United States)

    Weber, Konrad P; Straumann, Dominik

    2014-07-01

    This review summarizes the most relevant articles from the field of neuro-ophthalmology published in the Journal of Neurology from January 2012 to July 2013. With the advent of video-oculography, several articles describe new applications for eye movement recordings as a diagnostic tool for a wide range of disorders. In myasthenia gravis, anti-Kv1.4 and anti-Lrp4 have been characterized as promising novel autoantibodies for the diagnosis of hitherto 'seronegative' myasthenia gravis. Several articles address new diagnostic and therapeutic approaches to neuromyelitis optica, which further sharpen its profile as a distinct entity. Additionally, 4-aminopyridine has become a standard therapeutic for patients with cerebellar downbeat nystagmus. Finally, revised diagnostic criteria have been proposed for chronic relapsing inflammatory optic neuropathy based on a careful literature review over the last decade.

  2. Focused ultrasound in ophthalmology

    Directory of Open Access Journals (Sweden)

    Silverman RH

    2016-09-01

    Full Text Available Ronald H Silverman1,2 1Department of Ophthalmology, Columbia University Medical Center, 2F.L. Lizzi Center for Biomedical Engineering, Riverside Research, New York, NY, USA Abstract: The use of focused ultrasound to obtain diagnostically significant information about the eye goes back to the 1950s. This review describes the historical and technological development of ophthalmic ultrasound and its clinical application and impact. Ultrasound, like light, can be focused, which is crucial for formation of high-resolution, diagnostically useful images. Focused, single-element, mechanically scanned transducers are most common in ophthalmology. Specially designed transducers have been used to generate focused, high-intensity ultrasound that through thermal effects has been used to treat glaucoma (via cilio-destruction, tumors, and other pathologies. Linear and annular transducer arrays offer synthetic focusing in which precise timing of the excitation of independently addressable array elements allows formation of a converging wavefront to create a focus at one or more programmable depths. Most recently, linear array-based plane-wave ultrasound, in which the array emits an unfocused wavefront and focusing is performed solely on received data, has been demonstrated for imaging ocular anatomy and blood flow. While the history of ophthalmic ultrasound extends back over half-a-century, new and powerful technologic advances continue to be made, offering the prospect of novel diagnostic capabilities. Keywords: ophthalmic ultrasound, ultrasound biomicroscopy (UBM, high-intensity focused ultrasound (HIFU, ultrafast imaging, Doppler imaging 

  3. Noninvasive Diagnostic Technique in Stenotic Coronary Atherosclerosis

    Directory of Open Access Journals (Sweden)

    A. Yu. Vasilyev

    2005-01-01

    Full Text Available Objective: to determine the sensitivity and specificity of combined stress echocardiography (EchoCG using dipyri-damole and dobutamine in diagnosing and defining the extent of stenotic coronary lesions in coronary heart disease (CHD in a group of critically ill patients who are unable to perform a physical exercise.Materials and methods: the study included 57 male patients with suspected acute coronary syndrome who underwent stress EchoCG using dipyridamole in high doses in combination with dobutamine, as well as coronary angiography.Results: stress EchoCG could bring up to the diagnostic criteria in all the patients, of whom 9 patients were found at coronary angiography to have no coronary lesion, 34 and 14 patients had one- and many-vessel lesions, respectively. The sensitivity and specificity of combined stress EchoCG were significantly higher than those of EchoCG used in the diagnosis of CHD.Conclusion: stress EchoCG using dipyridamole in combination with dobutamine is a highly informative safe noninvasive technique for diagnosing CHD, its helps to identify patients with atypical acute coronary syndrome and to form a group of patients to be subject to urgent coronarography and angiosurgical intervention. The pattern of segmental contractile disorders at the height of exercise during combined stress Echo-CG makes it possible to define the site of stenotic coronary atherosclerosis with 97.3% sensitivity and to diagnose many-vessel lesion with 100% sensitivity and 100%specificity.

  4. Noise diagnostic: An advanced technique in Cuba

    International Nuclear Information System (INIS)

    Aguilar, O.

    1992-01-01

    This paper examines the main steps of the noise analysis technique implementation in our country from 1988. The review identifies two main areas, improvements of Nuclear Power Plant operational surveillance techniques and non-nuclear industrial applications. Also reported are some of the on going researches programs including projects on noise analysis instrumentation developments at the Higher Institute for Nuclear Sciences and Technology

  5. The Awareness of Health Professionals in Diagnostic Techniques ...

    African Journals Online (AJOL)

    hanumantp

    clear that most reviewed articles used the same conventional methods in ... Knowledge about the possible correlation of occult blood with reasons other than ... diagnostic techniques used in the examination of intestinal parasites in Gaza Strip.

  6. [Advances of Molecular Diagnostic Techniques Application in Clinical Diagnosis.

    Science.gov (United States)

    Ying, Bin-Wu

    2016-11-01

    Over the past 20 years,clinical molecular diagnostic technology has made rapid development,and became the most promising field in clinical laboratory medicine.In particular,with the development of genomics,clinical molecular diagnostic methods will reveal the nature of clinical diseases in a deeper level,thus guiding the clinical diagnosis and treatments.Many molecular diagnostic projects have been routinely applied in clinical works.This paper reviews the advances on application of clinical diagnostic techniques in infectious disease,tumor and genetic disorders,including nucleic acid amplification,biochip,next-generation sequencing,and automation molecular system,and so on.

  7. Essentials of diagnostic and interventional angiographic technique

    International Nuclear Information System (INIS)

    Gerlock, A.J.; Mirfakhraee, M.

    1985-01-01

    This volume presents coverage of basic angiographic techniques and shows how to get to the point of taking the angiogram, and tells how to avoid pitfalls. Particularly valuable is the information on how to get out of trouble if an error is made while manipulating the catheter

  8. Noninvasive Remote Sensing Techniques for Infrastructures Diagnostics

    Directory of Open Access Journals (Sweden)

    Angelo Palombo

    2011-01-01

    Full Text Available The present paper aims at analyzing the potentialities of noninvasive remote sensing techniques used for detecting the conservation status of infrastructures. The applied remote sensing techniques are ground-based microwave radar interferometer and InfraRed Thermography (IRT to study a particular structure planned and made in the framework of the ISTIMES project (funded by the European Commission in the frame of a joint Call “ICT and Security” of the Seventh Framework Programme. To exploit the effectiveness of the high-resolution remote sensing techniques applied we will use the high-frequency thermal camera to measure the structures oscillations by high-frequency analysis and ground-based microwave radar interferometer to measure the dynamic displacement of several points belonging to a large structure. The paper describes the preliminary research results and discusses on the future applicability and techniques developments for integrating high-frequency time series data of the thermal imagery and ground-based microwave radar interferometer data.

  9. Diagnostic techniques in deflagration and detonation studies.

    Science.gov (United States)

    Proud, William G; Williamson, David M; Field, John E; Walley, Stephen M

    2015-12-01

    Advances in experimental, high-speed techniques can be used to explore the processes occurring within energetic materials. This review describes techniques used to study a wide range of processes: hot-spot formation, ignition thresholds, deflagration, sensitivity and finally the detonation process. As this is a wide field the focus will be on small-scale experiments and quantitative studies. It is important that such studies are linked to predictive models, which inform the experimental design process. The stimuli range includes, thermal ignition, drop-weight, Hopkinson Bar and Plate Impact studies. Studies made with inert simulants are also included as these are important in differentiating between reactive response and purely mechanical behaviour.

  10. Mechanical system diagnostics using vibration testing techniques

    Science.gov (United States)

    Mcleod, Catherine D.; Raju, P. K.; Crocker, M. J.

    1990-01-01

    The 'Cepstrum' technique of vibration-path identification allows the recovery of the transfer function of a system with little knowledge as to its excitation force, by means of a mathematical manipulation of the system output in conjunction with subtraction of part of the output and suitable signal processing. An experimental program has been conducted to evaluate the usefulness of this technique in the cases of simple, cantilever-beam and free-free plate structures as well as in that of a complex mechanical system. On the basis of the transfer functions thus recovered, it was possible to evaluate the shifts in the resonance frequencies of a structure due to the presence of defects.

  11. Diagnostic techniques in cerebral artery occlusions

    Energy Technology Data Exchange (ETDEWEB)

    Huber, P

    1972-01-01

    In two-thrids of the cases of cerebral artery occlusions ophthalmodynamotry, thermography, and the fluorescein test are sufficient. In cases where these give insufficient data, scintigraphy is the preferred screening method. For determination of the regional blood flow /sup 133/Xe is used. Angiographic investigation, however, is the method that gives the most clinically valuable data. The techniques used and the risks inherent in the method are described. (JSR)

  12. Oncologic applications of diagnostic imaging techniques

    International Nuclear Information System (INIS)

    Forrest, L.J.; Thrall, D.E.

    1995-01-01

    Before appropriate therapy can be instituted for a cancer patient, the presence and extent of tumor must be evaluated. Deciding which imaging technique to use depends on tumor location, type, and biologic behavior. Conventional radiography provides important information at a relatively low cost compared with other imaging modalities. Ultrasound is a valuable adjunct to radiography, but does not replace it because both imaging modalities provide unique information. Nuclear medicine procedures contribute additional, unique data by providing physiological information, but specificity is lacking. Both CT and MRI provide images with exquisite anatomic detail, but availability and cost prohibit their general use

  13. Some novel diagnostic techniques for plasma chemistry

    International Nuclear Information System (INIS)

    Kaufman, M.

    1976-01-01

    In order to probe the mechanisms of chemical transformations in electric discharges it is most useful to monitor concentrations of reactants, products and reactive intermediates as a function of discharge parameters. Mass spectrometry, a popular technique for observing intermediates in chemical reactions, meets with particular difficulty when applied to discharges, due to the presence of excited molecules as well as free radicals in such systems. Molecular beam analysis, a synthesis of mass spectrometry with molecular beam measurements of electric and magnetic moments and velocity distributions, is a technique developed in the laboratory which offers distinct advantages for the analysis of intermediates in electric discharges. In low pressure discharges, end-product analysis can be facilitated by sample compression. A chromatographic sampling system which employs compression in order to achieve sensitivity has been developed and evaluated. There is some question concerning the appropriate discharge parameters to be employed in correlating measured variations in concentrations. An investigation is being made of the use of discharge 'actinometers' as a means of measuring the intensity of electric discharges. In discharges the intensity (number and energy of the electrons) and the chemistry are strongly coupled. Thus, it is necessary that the actinometer be present in the reactor; it is not permissible to substitute vessels as is customary in photochemical investigations. Since the actinometer is to measure only the discharge intensity, it must not participate in any chemical reactions with molecules and intermediates in the discharge. Finally, the ratio of the rates of the primary interactions of the actinometer and reactant with the discharge must be independent of discharge parameters. (author)

  14. Medical X-ray techniques in diagnostic radiography. 4. ed.

    International Nuclear Information System (INIS)

    Plaats, G.J. van der; Vijlbrief, P.

    1980-01-01

    A step by step account is given of every aspect of the technical factors involved in the production of X-ray images. Chapter titles include, methods of image formation and laws of projection, sharpness and unsharpness, contrast, perceptibility of detail in the radiographic image-image quality, properties of fluoroscopic screens, radiographic films, intensifying screens and cassettes, image intensification and X-ray television, processing technique, fluoroscopy and radiographic technique in general, special radiographic techniques, radiographic examinations using contrast media, exposure and exposure tables and automatic density control, diagnostic X-ray apparatus, and diagnostic stands and accessories. (C.F.)

  15. The Positron Emission Tomography. A diagnostic technique

    International Nuclear Information System (INIS)

    Salvadori, P.

    2001-01-01

    Positron Emission Tomography (PET) is a new imaging modality, which is able to assess non-invasively the biochemical mechanisms, underlying physiological and pathophysiological processes in vivo in humans. The technique relies on the administration of radioactive tracers labeled with short-lived positron emitters, which need to be produced on site via a particle accelerator (cyclotron). Radionuclides are produced upon request and formulated into biologically active organic molecules having precise pharmacokinetics and specificity. The radiotracer can be detected by the PET scanner and represented as tomographic sections (images of body sections) showing its regional distribution and concentration. This makes it possible to address clinical questions concerning occurrence and evolution of many diseases as well as their response to therapy. The ability to image (measure) biological processes and not only anatomy enables PET to explore diseases in the very early stage, including those diseases which are not related to modifications of organ structure (e.g. psychiatric diseases, metabolic disorders, biochemical disfunction). PET plays a major role, in conjunction with the other imaging modalities, to improve diagnosis capabilities and disease mechanism understanding [it

  16. Laser-based techniques for combustion diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Georgiev, N.

    1997-04-01

    Two-photon-induced Degenerate Four-Wave Mixing, DFWM, was applied for the first time to the detection of CO, and NH{sub 3} molecules. Measurements were performed in a cell, and in atmospheric-pressure flames. In the cell measurements, the signal dependence on the pressure and on the laser beam intensity was studied. The possibility of simultaneous detection of NH{sub 3} and OH was investigated. Carbon monoxide and ammonia were also detected employing two-photon-induced Polarization Spectroscopy, PS. In the measurements performed in a cold gas flow, the signal strength dependence on the laser intensity, and on the polarization of the pump beam, was investigated. An approach to improve the spatial resolution of the Amplified Stimulated Emission, ASE, was developed. In this approach, two laser beams at different frequencies were crossed in the sample. If the sum of the frequencies of the two laser beams matches a two photon resonance of the investigated species, only the molecules in the intersection volume will be excited. NH{sub 3} molecules and C atoms were studied. The potential of using two-photon LIF for two-dimensional imaging of combustion species was investigated. Although LIF is species specific, several species can be detected simultaneously by utilizing spectral coincidences. Combining one- and two-photon process, OH, NO, and O were detected simultaneously, as well as OH, NO, and NH{sub 3}. Collisional quenching is the major source of uncertainty in quantitative applications of LIF. A technique for two-dimensional, absolute species concentration measurements, circumventing the problems associated with collisional quenching, was developed. By applying simple mathematics to the ratio of two LIF signals generated from two counterpropagating laser beams, the absolute species concentration could be obtained. 41 refs

  17. Development of process diagnostic techniques for piping and equipment

    International Nuclear Information System (INIS)

    Yotsutsuji, Mitoshi

    1987-01-01

    The thing required for using the facilities composing a plant for a long period without anxiety is to quantitatively grasp the quantities of the present condition of the facilities and to take the necessary measures beforehand. For this purpose, the diagnostic techniques for quickly and accurately detect the quantities of the condition of facilities are necessary, and the development of process diagnostic techniques has been desired. The process diagnostic techniques mentioned here mean those for diagnosing the contamination, clogging and performance of towers, tanks, heat exchangers and others. Idemitsu Engineering Co. had developed a simplified diagnostic equipment for detecting the state of fouling in piping in 1982, which is the gamma ray transmission diagnosis named Scale Checker. By further improving it, the process diagnostic techniques for piping and equipment were developed. In this report, the course of development and examination, the principle of detection, the constitution and the examination of remodeling of the Scale Checker are reported. As the cases of process diagnosis in plant facilities, the diagnosis of the clogging in process piping and the diagnosis of the performance of a distillation tower were carried out. The contents of the diagnosis and the results of those cases are explained. (Kako, I.)

  18. Effectiveness of relaxation techniques before diagnostic screening of cancer patients

    Directory of Open Access Journals (Sweden)

    Montserrat Aiger

    2016-07-01

    Full Text Available Psychophysiological arousal was observed in cancer patients during the application of relaxation techniques prior to a diagnostic scan (PET-CT. The aim of the study is twofold: firstly, it is sought to establish whether such techniques can minimize patient arousal before diagnostic screening begins, and secondly to measure which of them are most effective. The dependent variable is electrodermal activity, recording the attentional level and emotional response, and the independent variable comprises the relaxation techniques used, namely Jacobson, breathing and visualization. The 39 patients were split into experimental groups to whom the relaxation techniques (Jacobson, breathing exercises, and visualization were applied before they went for the PET-CT. An activity-module procedure was applied to track electrodermal activity during the relaxation sessions, consisting of instructions, timeout; wait, task; relaxation and end of the recording session. The control group received no relaxation techniques before the PET-CT. Session-end results show that patients who perform relaxation techniques achieve greater attentional focus using Jacobson's technique (M = .212 and enhanced emotional containment using visualization (M = .206. It is concluded that relaxation techniques minimize the state of activation during the waiting period before a diagnostic scan.

  19. Electroencephalography as a diagnostic technique for canine neurological diseases

    Directory of Open Access Journals (Sweden)

    Wrzosek Marcin

    2016-06-01

    Full Text Available Electroencephalography (EEG is a non-invasive examination method for the assessment of functional central nervous system (CNS disturbances. In human medicine it has a special importance as a diagnostic tool for epilepsy. Although many studies were done on the use of EEG for diagnostics of canine central nervous system disorders, the technique is still not applied routinely. The purpose of this paper was to review the use of the electroencephalography in canine neurological disorders of central nervous system diagnosis and assess the future perspectives of this technique in veterinary medicine.

  20. Three dimensional imaging technique for laser-plasma diagnostics

    International Nuclear Information System (INIS)

    Jiang Shaoen; Zheng Zhijian; Liu Zhongli

    2001-01-01

    A CT technique for laser-plasma diagnostic and a three-dimensional (3D) image reconstruction program (CT3D) have been developed. The 3D images of the laser-plasma are reconstructed by using a multiplication algebraic reconstruction technique (MART) from five pinhole camera images obtained along different sight directions. The technique has been used to measure the three-dimensional distribution of X-ray of laser-plasma experiments in Xingguang II device, and the good results are obtained. This shows that a CT technique can be applied to ICF experiments

  1. Three dimensional imaging technique for laser-plasma diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Shaoen, Jiang; Zhijian, Zheng; Zhongli, Liu [China Academy of Engineering Physics, Chengdu (China)

    2001-04-01

    A CT technique for laser-plasma diagnostic and a three-dimensional (3D) image reconstruction program (CT3D) have been developed. The 3D images of the laser-plasma are reconstructed by using a multiplication algebraic reconstruction technique (MART) from five pinhole camera images obtained along different sight directions. The technique has been used to measure the three-dimensional distribution of X-ray of laser-plasma experiments in Xingguang II device, and the good results are obtained. This shows that a CT technique can be applied to ICF experiments.

  2. A new techniques in the physics of diagnostic radiology

    International Nuclear Information System (INIS)

    Jennings, R.J.

    1987-01-01

    The basic physics involved in the generation of X-rays and in the energy dependence of their interaction with matter are reviewed. Some applications of those ideas in both conventional X-ray imaging and in new imaging techniques are studied. Methods for the optimization of X-ray diagnostic imaging system are discussed. (M.A.C.) [pt

  3. Diagnostic techniques used in controlled thermonuclear research at Harwell

    Energy Technology Data Exchange (ETDEWEB)

    Harding, G N; Dellis, A N; Gibson, A; Jones, B; Lees, D J; McWhirter, R W.P.; Ramsden, S A; Ward, S [UK Atomic Energy Authority, AERE, Harwell (United Kingdom)

    1958-07-01

    This paper is a general survey of the lines along which diagnostic methods (spectroscopy, electrical measurements, and the study of high energy radiations) are developing at Harwell, and indicates the results which have been obtained so far. Many of the techniques are in a rudimentary state, and most of the Zeta experiments are incomplete.

  4. Nigerian Journal of Ophthalmology

    African Journals Online (AJOL)

    tulyasys

    Nigerian Journal of Ophthalmology / Jan-Jun 2014 / Vol 1 | Issue 1. I. Nigerian Journal of ... Inquiries about advertising should be sent to Medknow. Publications ... reproduce articles/information from this journal, please ... BUSINESS EDITOR.

  5. Imaging nuclear medicine techniques for diagnostic evaluation of arterial hypertension

    International Nuclear Information System (INIS)

    Eisenberg, B.M.; Linss, G.

    1989-01-01

    Arterial hypertension may be caused by a malfunction of organs and in turn may lead to secondary organic lesions. Modern diagnostic nuclear medicine is applied for function studies in order to detect or exclude secondary hypertension and functional or perfusion disturbances due to hypertension, or to assess and follow up hemodynamic conditions and cardiac functions prior to and during therapy. The article presents a survey of imaging diagnostic nuclear medicine techniques for the eamination of the heart, the brain, the kidneys and endocrine glands in patients with arterial hypertension, discussing the methods with a view to obtainable information, limits of detection, and indications. (orig.) [de

  6. Progress in diagnostic techniques for SC [superconducting] cavities

    International Nuclear Information System (INIS)

    Reece, C.E.

    1988-01-01

    Despite the very real progress that has been made, the routine performance of superconducting cavities still falls far short of both the theoretical expectations and the performance of afew exceptional examples. It is the task of systematically applied diagnostic techniques to reveal additional information concerning the response of superconducting surfaces to applied RF fields. In this paper we will direct our attention to discussions of recent developments in diagnostic techniqeus, such as thermometry in superfluid helium, and scanning laser acoustic microscopy. 18 refs., 12 figs

  7. Using Pattern Classification and Recognition Techniques for Diagnostic and Prediction

    Directory of Open Access Journals (Sweden)

    MORARIU, N.

    2007-04-01

    Full Text Available The paper presents some aspects regarding the joint use of classification and recognition techniques for the activity evolution diagnostication and prediction by means of a set of indexes. Starting from the indexes set there is defined a measure on the patterns set, measure representing a scalar value that characterizes the activity analyzed at each time moment. A pattern is defined by the values of the indexes set at a given time. Over the classes set obtained by means of the classification and recognition techniques is defined a relation that allows the representation of the evolution from negative evolution towards positive evolution. For the diagnostication and prediction the following tools are used: pattern recognition and multilayer perceptron. The data set used in experiments describes the pollution due to CO2 emission from the consumption of fuels in Europe. The paper also presents the REFORME software written by the authors and the results of the experiment obtained with this software.

  8. A clinicopathological study of various oral cancer diagnostic techniques

    Directory of Open Access Journals (Sweden)

    G Ulaganathan

    2017-01-01

    Full Text Available Oral cancer is one of the most commonly occurring malignant tumors in the head and neck regions with high incident rate and mortality rate in the developed countries than in the developing countries. Generally, the survival rate of cancer patients may increase when diagnosed at early stage, followed by prompt treatment and therapy. Recently, cancer diagnosis and therapy design for a specific cancer patient have been performed with the advanced computer-aided techniques. The responses of the cancer therapy could be continuously monitored to ensure the effectiveness of the treatment process that hardly requires diagnostic result as quick as possible to improve the quality and patient care. This paper gives an overview of oral cancer occurrence, different types, and various diagnostic techniques. In addition, a brief introduction is given to various stages of immunoanalysis including tissue image preparation, whole slide imaging, and microscopic image analysis.

  9. Fusion alpha loss diagnostic for ITER using activation technique

    Czech Academy of Sciences Publication Activity Database

    Bonheure, G.; Hult, M.; González de Orduña, R.; Vermaercke, P.; Murari, A.; Popovichev, S.; Mlynář, Jan

    2011-01-01

    Roč. 86, 6-8 (2011), s. 1298-1301 ISSN 0920-3796. [Symposium on Fusion Technology (SOFT) /26th./. Port o, 27.09.2010-01.10.2010] Institutional research plan: CEZ:AV0Z20430508 Keywords : ITER * fusion product * burning plasma diagnostics * alpha losses * activation technique Subject RIV: BL - Plasma and Gas Discharge Physics Impact factor: 1.490, year: 2011 http://www.sciencedirect.com/science/article/pii/S0920379611002778

  10. Imaging mammary diagnostics. Diagnostic techniques, archetypical findings, differential diagnostcs and interventions. 2. rev. and enl. ed.

    International Nuclear Information System (INIS)

    Heywang-Koebrunner, S.; Schreer, I.

    2008-01-01

    The book includes the following chapters: I. Methodology: anamnesis and interview; clinical evidence, mammography, sonography, magnetic resonance tomography, new imaging techniques (scintigraphy, PET), transcutaneous biopsy, pre-operative marking; II. phenotypes: normal mammary glands, mastopathics, cysts, benign tumors, inflammatory diseases, in-situ carcinomas, invasive carcinomas, lymphomas, other semi-malign and malign tumors, post-traumatic, post-surgical and post-therapeutic changes, skin changes, male mamma, screening, continuative diagnostics of screening evidence and problem solving for symptomatic patients

  11. LeRC rail accelerators: test designs and diagnostic techniques

    International Nuclear Information System (INIS)

    Zana, L.M.; Kerslake, W.R.; Sturman, J.C.; Wang, S.Y.; Terdan, F.F.

    1984-01-01

    The feasibility of using rail accelerators for various in-space and to-space propulsion applications was investigated. A 1 meter, 24 sq mm bore accelerator was designed with the goal of demonstrating projectile velocities of 15 km/sec using a peak current of 200 kA. A second rail accelerator, 1 meter long with a 156.25 sq mm bore, was designed with clear polycarbonate sidewalls to permit visual observation of the plasma arc. A study of available diagnostic techniques and their application to the rail accelerator is presented. Specific topics of discussion include the use of interferometry and spectroscopy to examine the plasma armature as well as the use of optical sensors to measure rail displacement during acceleration. Standard diagnostics such as current and voltage measurements are also discussed. 15 references

  12. Diagnostic accuracy of new imaging techniques in breast diseases

    Energy Technology Data Exchange (ETDEWEB)

    Gordenne, W; Bauduin, E [Liege Univ. (Belgium)

    1989-01-01

    During the last decade, the hypothetical carcinogenic effects of mammography have lead to new technical developments in X-ray diagnosis and to use of other imaging techniques such as ultrasonography (US), transillumination, magnetic resonance imaging (MRI). Many preliminary studies were published but few clinical trials are really convincing. According to the definition of a diagnostic tool, none of these new modalities is supposed to supplant mammography in the diagnosis of breast cancer. Improvements are expected by digital mammography in the near future. (Authors).

  13. Improvement of Railroad Roller Bearing Test Procedures & Development of Roller Bearing Diagnostic Techniques. Volume 2.

    Science.gov (United States)

    1982-04-01

    A comprehensive review of existing basic diagnostic techniques applicable to the railcar roller bearing defect and failure problem was made. Of the potentially feasible diagnostic techniques identified, high frequency vibration was selected for exper...

  14. New diagnostic technique for Zeeman-compensated atomic beam slowing: technique and results

    NARCIS (Netherlands)

    Molenaar, P.A.; Straten, P. van der; Heideman, H.G.M.; Metcalf, H.

    1997-01-01

    We have developed a new diagnostic tool for the study of Zeeman-compensated slowing of an alkali atomic beam. Our time-of-flight technique measures the longitudinal veloc- ity distribution of the slowed atoms with a resolution below the Doppler limit of 30 cm/s. Furthermore, it can map

  15. [Basic research in ophthalmology in Germany and its international context].

    Science.gov (United States)

    Schlötzer-Schrehardt, U; Cursiefen, C

    2017-09-01

    Experimental basic research provides the foundations for the elucidation of pathophysiological mechanisms of diseases and the development of novel diagnostic and therapeutic strategies for ophthalmological diseases. The objective of this contribution is to provide an overview of the international interconnection of basic research in ophthalmology in Germany. The international context of ophthalmological research conducted in Germany is presented by means of personal experiences and data published by the German Ophthalmological Society (DOG), the German Research Foundation (DFG) and the European Union (EU). Due to the lack of organized databases this article lays no claim to completeness. Basic research in ophthalmology in Germany is mainly conducted in university eye departments and is mainly related to the etiology, pathophysiology and therapy development for various ophthalmic diseases. It is primarily funded by the DFG, the Federal Ministry of Education and Research (BMBF) and the EU plays an increasingly important role. Thus, ophthalmological research is integrated into numerous European research networks and beyond that into many international interconnections and relationships. In Germany, both clinical and basic research in ophthalmology is integrated into many international networks and is only functionally viable in an international context; however, given the increasing impact of ophthalmological research in Asian countries, future strategies require a continued focus on career development, research infrastructure, working environment and international cooperation.

  16. Lasers in Ophthalmology

    Institute of Scientific and Technical Information of China (English)

    1992-01-01

    In recent years,lasers have entered every fieldof medicine and especially so in ophthalmol-ogy.The scientific basis of lasers in ophthal-mology is based on three mechanisms:1.Photothermal effectLasers:argon,krypton,dye and diodeA thermal effect is generated when laserenergy is absorbed by pigment leading to in-creased vibration and therefore heat content.A

  17. Tests for malingering in ophthalmology

    Directory of Open Access Journals (Sweden)

    Ali Ihsan Incesu

    2013-10-01

    Full Text Available Simulation can be defined as malingering, or sometimes functional visual loss (FVL. It manifests as either simulating an ophthalmic disease (positive simulation, or denial of ophthalmic disease (negative simulation. Conscious behavior and compensation or indemnity claims are prominent features of simulation. Since some authors suggest that this is a manifestation of underlying psychopathology, even conversion is included in this context. In today’s world, every ophthalmologist can face with simulation of ophthalmic disease or disorder. In case of simulation suspect, the physician’s responsibility is to prove the simulation considering the disease/disorder first, and simulation as an exclusion. In simulation examinations, the physician should be firm and smart to select appropriate test(s to convince not only the subject, but also the judge in case of indemnity or compensation trials. Almost all ophthalmic sensory and motor functions including visual acuity, visual field, color vision and night vision can be the subject of simulation. Examiner must be skillful in selecting the most appropriate test. Apart from those in the literature, we included all kinds of simulation in ophthalmology. In addition, simulation examination techniques, such as, use of optical coherence tomography, frequency doubling perimetry (FDP, and modified polarization tests were also included. In this review, we made a thorough literature search, and added our experiences to give the readers up-to-date information on malingering or simulation in ophthalmology.

  18. Resonant laser techniques for combustion and flow diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Fritzon, Rolf

    1998-05-01

    This thesis presents results from two areas of research. Firstly, the resonant coherent laser techniques polarization spectroscopy (PS), degenerate four-wave mixing (DFWM) and stimulated emission (SE) have been developed in the general field of combustion diagnostics. Secondly, laser induced fluorescence (LIF) has been developed and applied for the visualization of mixture fractions in turbulent non reacting flows. PS was developed for instantaneous two-dimensional imaging of minor species in flames, the technique being demonstrated on OH and NO. Various aspects of imaging and of detection in general were investigated. Two-photon induced PS was demonstrated for the detection of NH{sub 3}, CO and N{sub 2} molecules. LIF was monitored simultaneously to allow a quantitative comparison between the techniques. Furthermore, PS and DFWM were developed for instantaneous two-dimensional OH temperature imaging. Through a novel experimental approach based on the use of a dual-wavelength dye laser and a diffraction grating the temperature imaging measurements were performed using only one laser and one CCD camera. A comparison between the two techniques was made. SE was through a crossed-beam arrangement developed for spatially resolved detection of flame species. Two-dimensional LIF was developed and applied for measuring mixture fractions in the shear layer between two co-flowing turbulent gaseous jets. The technique was further applied in a study of the mixing of a turbulent water jet impinging orthogonally onto a flat surface. Average concentration fields in the center-plane of the jet was compared with results from large eddy simulations and with data from the literature 221 refs, 48 figs, 5 tabs

  19. Laser diagnodent: a comparative study with other diagnostic techniques

    International Nuclear Information System (INIS)

    Godinho, Reugma Rego

    2002-01-01

    An evaluation of the Diagnodent equipment (Kavo Company, Germany) for the occlusal caries detection was dane through the comparison with other conventional diagnostic techniques, such as visual inspection, intra-oral micro camera and digital X-ray. The effectiveness of the equipment in the detection of hidden caries and its viability as a diagnosis method for caries in their initial stage was also studied. Fifty eight permanent molars and premolars teeth from patients with age between 6 and 30 years were studied. The obtained results indicated that the conventional methods employed for the caries diagnosis are unable to detect the carious lesion in its initial stage. The Diagnodent equipment has this capability to detect caries presenting a flawless surface, specially the hidden caries, allowing the dentist to decide between a preventive ar a conservative procedure. The main advantage of the Diagnodent is to be an objective method, compared to the visual and radiographic ones, that are dependent on the professional interpretation. The Diagnodent is, therefore, a promising alternative as an objective and standardized diagnosis method for the final diagnostic. (author)

  20. Reliability of diagnostic imaging techniques in suspected acute appendicitis: proposed diagnostic protocol

    International Nuclear Information System (INIS)

    Cura del, J. L.; Oleaga, L.; Grande, D.; Vela, A. C.; Ibanez, A. M.

    2001-01-01

    To study the utility of ultrasound and computed tomography (CT) in case of suspected appendicitis. To determine the diagnostic yield in terms of different clinical contexts and patient characteristics. to assess the costs and benefits of introducing these techniques and propose a protocol for their use. Negative appendectomies, complications and length of hospital stay in a group of 152 patients with suspected appendicitis who underwent ultrasound and CT were compared with those of 180 patients who underwent appendectomy during the same time period, but had not been selected for the first group: these patients costs for each group were calculated. In the first group, the diagnostic value of the clinical signs was also evaluated. The reliability of the clinical signs was limited, while the results with ultrasound and CT were excellent. The incidence of negative appendectomy was 9.6% in the study group and 12.2% in the control group. Moreover, there were fewer complications and a shorter hospital stay in the first group. Among men, however, the rate of negative appendectomy was lower in the control group. The cost of using ultrasound and CT in the management of appendicitis was only slightly higher than that of the control group. Although ultrasound and CT are not necessary in cases in which the probability of appendicitis is low or in men presenting clear clinical evidence, the use of these techniques is indicated in the remaining cases in which appendicitis is suspected. In children, ultrasound is the technique of choice. In all other patients, if negative results are obtained with one of the two techniques, the other should be performed. (Author) 49 refs

  1. Diagnostics

    DEFF Research Database (Denmark)

    Donné, A.J.H.; Costley, A.E.; Barnsley, R.

    2007-01-01

    of the measurements—time and spatial resolutions, etc—will in some cases be more stringent. Many of the measurements will be used in the real time control of the plasma driving a requirement for very high reliability in the systems (diagnostics) that provide the measurements. The implementation of diagnostic systems...... on ITER is a substantial challenge. Because of the harsh environment (high levels of neutron and gamma fluxes, neutron heating, particle bombardment) diagnostic system selection and design has to cope with a range of phenomena not previously encountered in diagnostic design. Extensive design and R......&D is needed to prepare the systems. In some cases the environmental difficulties are so severe that new diagnostic techniques are required. The starting point in the development of diagnostics for ITER is to define the measurement requirements and develop their justification. It is necessary to include all...

  2. Feedback of final year ophthalmology postgraduates about their residency ophthalmology training in South India

    Directory of Open Access Journals (Sweden)

    K Ajay

    2014-01-01

    Full Text Available Background and Aims: This study documents a survey of final-year ophthalmology postgraduate students on the subject of their residency training. A similar survey conducted 7 years ago published in IJO had concluded that the residency program was not up to expectations in many centers. Our study aimed to see if ophthalmology training and student perceptions differed since then. Materials and Methods: For our study, we added a few questions to the same questionnaire used in the article "which is the best method to learn ophthalmology? Resident doctors′ perspective of ophthalmology training" published in IJO, Vol. 56 (5. Results: Forty-nine students (62.02% returned completed forms. Most students desired an orientation program on entering residency, and wished to undergo diagnostic training initially. Case-presentation with demonstration and Wet-lab learning were most preferred. There was a big difference between the number of surgeries students actually performed and the number they felt would have been ideal. Conclusion: On the whole, the students still felt the need for improved training across all aspects of ophthalmology.

  3. New diagnostic technique for Zeeman-compensated atomic beam slowing: technique and results

    OpenAIRE

    Molenaar, P.A.; Straten, P. van der; Heideman, H.G.M.; Metcalf, H.

    1997-01-01

    We have developed a new diagnostic tool for the study of Zeeman-compensated slowing of an alkali atomic beam. Our time-of-flight technique measures the longitudinal veloc- ity distribution of the slowed atoms with a resolution below the Doppler limit of 30 cm/s. Furthermore, it can map the position and velocity distribution of atoms in either ground hyperfine level inside the solenoid without any devices inside the solenoid. The technique reveals the optical pumping ef- fects, and shows in de...

  4. Selection of suitable diagnostic techniques for an RF atmospheric pressure plasma

    International Nuclear Information System (INIS)

    Kong, M.G.; Deng, X.T.

    2001-01-01

    As an early report of our study, this paper summaries the RF atmospheric pressure plasma system we intend to characterize and a number of diagnostic techniques presently under assessment for our plasma rig. By discussing the advantages and disadvantages of these diagnostic techniques at this meeting, we hope to gain feedback and comments to improve our choice of appropriate diagnostic techniques as well as our subsequent application of these techniques to nonthermal RF atmospheric pressure plasmas

  5. Development of advanced strain diagnostic techniques for reactor environments.

    Energy Technology Data Exchange (ETDEWEB)

    Fleming, Darryn D.; Holschuh, Thomas Vernon,; Miller, Timothy J.; Hall, Aaron Christopher; Urrea, David Anthony,; Parma, Edward J.,

    2013-02-01

    The following research is operated as a Laboratory Directed Research and Development (LDRD) initiative at Sandia National Laboratories. The long-term goals of the program include sophisticated diagnostics of advanced fuels testing for nuclear reactors for the Department of Energy (DOE) Gen IV program, with the future capability to provide real-time measurement of strain in fuel rod cladding during operation in situ at any research or power reactor in the United States. By quantifying the stress and strain in fuel rods, it is possible to significantly improve fuel rod design, and consequently, to improve the performance and lifetime of the cladding. During the past year of this program, two sets of experiments were performed: small-scale tests to ensure reliability of the gages, and reactor pulse experiments involving the most viable samples in the Annulated Core Research Reactor (ACRR), located onsite at Sandia. Strain measurement techniques that can provide useful data in the extreme environment of a nuclear reactor core are needed to characterize nuclear fuel rods. This report documents the progression of solutions to this issue that were explored for feasibility in FY12 at Sandia National Laboratories, Albuquerque, NM.

  6. Therapeutic application of lasers in ophthalmology; Terapeutyczne zastosowanie laserow w okulistyce

    Energy Technology Data Exchange (ETDEWEB)

    Misiuk-Hojlo, M; Krzyzanowska-Berkowska, P; Hill-Bator, A [Department of Ophthalmology, Silesian Piasts University of Medicine in Wroclaw (Poland)

    2007-07-01

    Lasers have found application in diverse branches of medicine. In ophthalmology, laser technology has various therapeutic and diagnostic applications. The purpose of this article is to review the major therapeutic applications of lasers in different eye disorders. The effects of lasers on biological tissues and different laser techniques as well as the indications for laser therapy in various parts of the eye are discussed. Lasers are used to treat glaucoma and many vascular disorders of the retina. Laser treatment may be useful in preventing the development of neovascularization in diabetic retinopathy, BRVO, or CRVO. Laser techniques are also available for the treatment of the exudative form of age-related macular degeneration (AMD) and some malignant and benign intraocular tumors and in retina abnormalities which predispose to rhegmatogenous retinal detachment. Corneal laser surgery is the most frequently applied laser procedure in ophthalmology. PRK, LASIK, and LASEK are used to correct errors in vision such as myopia, hyperopia, and astigmatism. Laser photocoagulation is also helpful in cataract surgery. Nowadays, lasers have become so universal that it is difficult to imagine ophthalmology without them. We are still witnessing rapid advances in the development of laser techniques, especially in plastic surgery, cataract extraction, and ocular imaging. (authors)

  7. Monte Carlo techniques in diagnostic and therapeutic nuclear medicine

    International Nuclear Information System (INIS)

    Zaidi, H.

    2002-01-01

    Monte Carlo techniques have become one of the most popular tools in different areas of medical radiation physics following the development and subsequent implementation of powerful computing systems for clinical use. In particular, they have been extensively applied to simulate processes involving random behaviour and to quantify physical parameters that are difficult or even impossible to calculate analytically or to determine by experimental measurements. The use of the Monte Carlo method to simulate radiation transport turned out to be the most accurate means of predicting absorbed dose distributions and other quantities of interest in the radiation treatment of cancer patients using either external or radionuclide radiotherapy. The same trend has occurred for the estimation of the absorbed dose in diagnostic procedures using radionuclides. There is broad consensus in accepting that the earliest Monte Carlo calculations in medical radiation physics were made in the area of nuclear medicine, where the technique was used for dosimetry modelling and computations. Formalism and data based on Monte Carlo calculations, developed by the Medical Internal Radiation Dose (MIRD) committee of the Society of Nuclear Medicine, were published in a series of supplements to the Journal of Nuclear Medicine, the first one being released in 1968. Some of these pamphlets made extensive use of Monte Carlo calculations to derive specific absorbed fractions for electron and photon sources uniformly distributed in organs of mathematical phantoms. Interest in Monte Carlo-based dose calculations with β-emitters has been revived with the application of radiolabelled monoclonal antibodies to radioimmunotherapy. As a consequence of this generalized use, many questions are being raised primarily about the need and potential of Monte Carlo techniques, but also about how accurate it really is, what would it take to apply it clinically and make it available widely to the medical physics

  8. Fibrin glue in ophthalmology

    Directory of Open Access Journals (Sweden)

    Panda Anita

    2009-01-01

    Full Text Available Suturing is a time consuming task in ophthalmology and suture induced irritation and redness are frequent problems. Postoperative wound infection and corneal graft rejection are examples of possible suture related complications. To prevent these complications, ophthalmic surgeons are switching to sutureless surgery. A number of recent developments have established tissue adhesives like cyanoacrylate glue and fibrin glue as attractive alternatives to sutures. A possible and promising new application for tissue adhesives is to provide a platform for tissue engineering. Currently, tissue glue is being used for conjunctival closure following pterygium and strabismus surgery, forniceal reconstruction surgery, amniotic membrane transplantation, lamellar corneal grafting, closure of corneal perforations and descematoceles, management of conjunctival wound leaks after trabeculectomy, lid surgery, adnexal surgery and as a hemostat to minimise bleeding. The purpose of this review is to discuss the currently available information on fibrin glue.

  9. Diagnostic imaging techniques in Rubinstein-Taybi syndrome

    International Nuclear Information System (INIS)

    Albanese, A.; Carcione, A.; Benenati, A.; Albano, S.; Rubino, F.P.; Reina, C.; Verde, V.; Giuffre, L.; Corsello, G.; Cammarata, M.; Piccione, M.

    1991-01-01

    Both etiology and pathogenesis of Rubinstein-Taybi syndrome (RTS) are still questionable, even though a genetic factor seems to be certain. A typical face, psychomotor delay, and thumb and halluces abnormalities (big, prevalently short, and often 'spoon-like' toes) are the main characteristic patterns of RTS. Eight subjects (4 male and 3 female children aged 26 days-7 years, and a 31-year old woman, mother of 1 of the affected children) with different signs of RTS were studied over the last 3 years. The results are here reported, with a special emphasis on malformations detected with conventional radiography (Rx), Computerized Tomography (CT), and ultrasound (US). Evaluated parameters were thumbs and halluces (Rx), bone age and skeleton (Rx), cranium (Rx) and encephalon (US, CT), cryptochidism (US, CT), and urogical (Rx, US) and carciovascolar (US) system. Atypical face and psycomotor delay were found in all cases, while thumb and halluces abnormalities were observed only in 6 cases. Among several clinical signs of RTS, we found: severe (<3rd centile) bone maturation delay in 4 cases; skull volume reduction (<50th centile) in 3 subjects and microcrania in 4; skeletal abnormalities in 7 cases (5 of them positive for bilateral coxofemoral abnormalities); urinary tract (4 cases) and cardiovascular (3 cases) malformation; and cryptorcidism in 3 of 4 males. A case was diagnosed during neonatal period (within the first month of life) it was a rare case associated with a variant form of Dandy-Walker anomaly; semiologic similarities were observed between mother and daughter patients. X-rays, US and CT rarely play an important role in the diagnosis of RTS, considering the several clinical signs, mainly tha face, affecting the patients. However, diagnostic imaging techniques help diagnose hidden malformations and confirm and integrate clinical signs

  10. Neuro-ophthalmology | Bekibele | Nigerian Journal of Ophthalmology

    African Journals Online (AJOL)

    Nigerian Journal of Ophthalmology. Journal Home · ABOUT THIS JOURNAL · Advanced Search · Current Issue · Archives · Journal Home > Vol 23, No 3 (2015) >. Log in or Register to get access to full text downloads.

  11. Neuro-ophthalmology as a career.

    Science.gov (United States)

    Spitze, Arielle; Al-Zubidi, Nagham; Lam, Peter; Yalamanchili, Sushma; Lee, Andrew G

    2014-10-01

    This essay was written to discuss the reasoning behind the personal decisions made by 2 current neuro-ophthalmology fellows to pursue neuro-ophthalmology as a career. It is meant to enlighten the reader about what role neuro-ophthalmologists play in clinical practice, what makes neuro-ophthalmology unique to all other sub-specialties, and how this contributes to making neuro-ophthalmology not only one of the most medically interesting, yet rewarding sub-specialties in ophthalmology.

  12. Indications and new diagnostic techniques in micturating cystourethrographic studies

    International Nuclear Information System (INIS)

    Schuster, W.; Bruenger, J.

    1978-01-01

    Urological radiographic procedures on children are of great importance. The frequency of examinations is comparable to the number of Gl tract studies. In diagnosing chronically recurrent urinary tract infections, micturating cystourethrography is a valuable addition to excretory urography. Indications and performance of micturating cystourethrography at juvenile age are described. All measures reducing radiation exposure must be taken into consideration. New technological devices grant improved diagnostic information with a minimal radiation exposure for patients. (orig.) [de

  13. Tunable diode laser spectroscopy as a technique for combustion diagnostics

    International Nuclear Information System (INIS)

    Bolshov, M.A.; Kuritsyn, Yu.A.; Romanovskii, Yu.V.

    2015-01-01

    Tunable diode laser absorption spectroscopy (TDLAS) has become a proven method of rapid gas diagnostics. In the present review an overview of the state of the art of TDL-based sensors and their applications for measurements of temperature, pressure, and species concentrations of gas components in harsh environments is given. In particular, the contemporary tunable diode laser systems, various methods of absorption detection (direct absorption measurements, wavelength modulation based phase sensitive detection), and relevant algorithms for data processing that improve accuracy and accelerate the diagnostics cycle are discussed in detail. The paper demonstrates how the recent developments of these methods and algorithms made it possible to extend the functionality of TDLAS in the tomographic imaging of combustion processes. Some prominent examples of applications of TDL-based sensors in a wide range of practical combustion aggregates, including scramjet engines and facilities, internal combustion engines, pulse detonation combustors, and coal gasifiers, are given in the final part of the review. - Highlights: • Overview of modern TDL-based sensors for combustion • TDL systems, methods of absorption detection and algorithms of data processing • Prominent examples of TDLAS diagnostics of the combustion facilities • Extension of the TDLAS on the tomographic imaging of combustion processes

  14. Intracranial Aneurysms of Neuro-Ophthalmologic Relevance.

    Science.gov (United States)

    Micieli, Jonathan A; Newman, Nancy J; Barrow, Daniel L; Biousse, Valérie

    2017-12-01

    Intracranial saccular aneurysms are acquired lesions that often present with neuro-ophthalmologic symptoms and signs. Recent advances in neurosurgical techniques, endovascular treatments, and neurocritical care have improved the optimal management of symptomatic unruptured aneurysms, but whether the chosen treatment has an impact on neuro-ophthalmologic outcomes remains debated. A review of the literature focused on neuro-ophthalmic manifestations and treatment of intracranial aneurysms with specific relevance to neuro-ophthalmologic outcomes was conducted using Ovid MEDLINE and EMBASE databases. Cavernous sinus aneurysms were not included in this review. Surgical clipping vs endovascular coiling for aneurysms causing third nerve palsies was compared in 13 retrospective studies representing 447 patients. Complete recovery was achieved in 78% of surgical patients compared with 44% of patients treated with endovascular coiling. However, the complication rate, hospital costs, and days spent in intensive care were reported as higher in surgically treated patients. Retrospective reviews of surgical clipping and endovascular coiling for all ocular motor nerve palsies (third, fourth, or sixth cranial nerves) revealed similar results of complete resolution in 76% and 49%, respectively. Improvement in visual deficits related to aneurysmal compression of the anterior visual pathways was also better among patients treated with clipping than with coiling. The time to treatment from onset of visual symptoms was a predictive factor of visual recovery in several studies. Few reports have specifically assessed the improvement of visual deficits after treatment with flow diverters. Decisions regarding the choice of therapy for intracranial aneurysms causing neuro-ophthalmologic signs ideally should be made at high-volume centers with access to both surgical and endovascular treatments. The status of the patient, location of the aneurysm, and experience of the treating physicians

  15. A review on diagnostic techniques for brucellosis | Kaltungo | African ...

    African Journals Online (AJOL)

    ... but has not been validated for standard laboratory use. This paper highlights useful samples and, especially the different conventional to more sophisticated molecular techniques for the diagnosis of brucellosis. Keywords: Brucellosis, diagnosis, techniques. African Journal of Biotechnology, Vol. 13(1), pp. 1-10, 1 January, ...

  16. Endoscopy as a diagnostic and therapeutic alternative technique of taeniasis.

    Science.gov (United States)

    Canaval Zuleta, Héctor Julián; Company Campins, María M; Dolz Abadía, Carlos

    2016-06-01

    Despite a low incidence in developed countries, gastrointestinal taeniasis should be suspected in patients with abdominal pain, diarrhea, anemia, and/or malabsorption of unknown origin, even more so if they come from endemic regions or areas with poor hygienic and alimentary habits. Diagnosis is traditionally reached by identifying the parasite in stools, but more recently both serological and immunological approaches are also available. Based on a patient diagnosed by gastroscopy, a literature review was undertaken of patients diagnosed by endoscopy. We discuss endoscopy as diagnostic modality, and the effectiveness and safety that endoscopic treatment may provide in view of the potential risk for neurocysticercosis.

  17. Endoscopy as a diagnostic and therapeutic alternative technique of taeniasis

    Directory of Open Access Journals (Sweden)

    Héctor Julian Canaval-Zuleta

    Full Text Available Despite a low incidence in developed countries, gastrointestinal taeniasis should be suspected in patients with abdominal pain, diarrhea, anemia, and/or malabsorption of unknown origin, even more so if they come from endemic regions or areas with poor hygienic and alimentary habits. Diagnosis is traditionally reached by identifying the parasite in stools, but more recently both serological and immunological approaches are also available. Based on a patient diagnosed by gastroscopy, a literature review was undertaken of patients diagnosed by endoscopy. We discuss endoscopy as diagnostic modality, and the effectiveness and safety that endoscopic treatment may provide in view of the potential risk for neurocysticercosis.

  18. Action Research to Improve the Learning Space for Diagnostic Techniques

    Directory of Open Access Journals (Sweden)

    Ellen Ariel

    2015-08-01

    Full Text Available The module described and evaluated here was created in response to perceived learning difficulties in diagnostic test design and interpretation for students in third-year Clinical Microbiology. Previously, the activities in lectures and laboratory classes in the module fell into the lower cognitive operations of “knowledge” and “understanding.” The new approach was to exchange part of the traditional activities with elements of interactive learning, where students had the opportunity to engage in deep learning using a variety of learning styles. The effectiveness of the new curriculum was assessed by means of on-course student assessment throughout the module, a final exam, an anonymous questionnaire on student evaluation of the different activities and a focus group of volunteers. Although the new curriculum enabled a major part of the student cohort to achieve higher pass grades (p < 0.001, it did not meet the requirements of the weaker students, and the proportion of the students failing the module remained at 34%. The action research applied here provided a number of valuable suggestions from students on how to improve future curricula from their perspective. Most importantly, an interactive online program that facilitated flexibility in the learning space for the different reagents and their interaction in diagnostic tests was proposed. The methods applied to improve and assess a curriculum refresh by involving students as partners in the process, as well as the outcomes, are discussed.

  19. Action Research to Improve the Learning Space for Diagnostic Techniques.

    Science.gov (United States)

    Ariel, Ellen; Owens, Leigh

    2015-12-01

    The module described and evaluated here was created in response to perceived learning difficulties in diagnostic test design and interpretation for students in third-year Clinical Microbiology. Previously, the activities in lectures and laboratory classes in the module fell into the lower cognitive operations of "knowledge" and "understanding." The new approach was to exchange part of the traditional activities with elements of interactive learning, where students had the opportunity to engage in deep learning using a variety of learning styles. The effectiveness of the new curriculum was assessed by means of on-course student assessment throughout the module, a final exam, an anonymous questionnaire on student evaluation of the different activities and a focus group of volunteers. Although the new curriculum enabled a major part of the student cohort to achieve higher pass grades (p < 0.001), it did not meet the requirements of the weaker students, and the proportion of the students failing the module remained at 34%. The action research applied here provided a number of valuable suggestions from students on how to improve future curricula from their perspective. Most importantly, an interactive online program that facilitated flexibility in the learning space for the different reagents and their interaction in diagnostic tests was proposed. The methods applied to improve and assess a curriculum refresh by involving students as partners in the process, as well as the outcomes, are discussed. Journal of Microbiology & Biology Education.

  20. Dose classification scheme for digital imaging techniques in diagnostic radiology

    International Nuclear Information System (INIS)

    Hojreh, A.

    2002-04-01

    Purpose: image quality in diagnostic radiology is determined in crucial extent by the signal-noise-ratio, which is proportional to the applied x-ray dose. Onward technological developments in the diagnostic radiology are therefore frequently connected with a dose increase, which subjectively is hardly or even not perceptible. The aim of this work was to define reproducible standards for image quality as a function of dose and expected therapeutical consequence in case of computed tomography of the paranasal sinuses and the upper and lower jaw (dental CT), whereby practical-clinical purposes are considered. Materials and methods: the image quality of computed tomography of the paranasal sinuses and dental CT was determined by standard deviation of the CT-numbers (pixel noise) in a region of interest of the phantom of American Association of Physicists in Medicine (AAPM phantom) and additionally in the patients CT images. The diagnostic quality of the examination was classified on the basis of patients CT images in three dose levels (low dose, standard dose and high dose). Results: the pixel noise of CT of the paranasal sinuses with soft tissue reconstruction amounts to 19.3 Hounsfield units (HU) for low dose, 8.8 HU for standard dose, and below 8 HU for high dose. The pixel noise of the dental CT with bone (high resolution) reconstruction amounts to 344 HU for low dose, 221 HU for standard dose, and below 200 HU for high dose. Suitable indications for low dose CT are the scanning of body regions with high contrast differences, like the bony delimitations of air-filled spaces of the facial bones, and radiological follow-up examinations with dedicated questions such as axis determination in dental implantology, as well as the images of objects with small diameter such as in case of children. The standard dose CT can be recommended for all cases, in which precise staging of the illness plays an indispensable role for the diagnosis and therapy planning. With high dose

  1. Novel non-intercepting diagnostic techniques for low-emittance relativistic electron beams

    International Nuclear Information System (INIS)

    Moran, M.J.; Chang, B.

    1988-01-01

    Relativistic electron beams are being generated with emittances low enough that diffraction radiation can be used for beam diagnostics. Techniques based on diffraction radiation can be used to measure the beam transverse momentum distribution and to measure the transverse spatial distribution. The radiation is intense and can be in the visible spectral region where optical diagnostic techniques can be used to maximum advantage. 4 refs. 3 figs

  2. Two cases of colossal heamtometra in old women with a difficult preoperative diagnostic technique

    International Nuclear Information System (INIS)

    Aono, Kaname; Fukumoto, Satoru

    1980-01-01

    With the progress in diagnostic imaging techniques, the preoperative diagnostic technique for lesion in the pelvic cavity has become comparatively easy and its clinical usefulness is in high estimation. However, in case of an atypical lesion, it is not always easy to recognize the original organ by traditional imaging pattern. In the present report two cases of colossal hematometra in old women which presented a cystic lesion pattern are dealt with and discussed from a point of medical imagings for diagnosis. (author)

  3. Diagnostic methods and techniques in cervical cancer prevention Part II: Molecular diagnostics of HPV infection

    Directory of Open Access Journals (Sweden)

    Adriana Vince,

    2010-02-01

    Full Text Available Clinical diagnostics of HPV infection is based on analytically andclinically validated assays for qualitative detection of HPV DNAfrom high risk genotypes. New generation of HPV DNA assayscombines qualitative detection of 12 high-risk HPV genotypeswith HPV-16 and HPV-18 genotyping. New generation of HPVmolecular assays designed to increase clinical specificity of moleculartesting is based on detection of mRNA for E6 and E7.

  4. Ophthalmologic complications of systemic disease.

    Science.gov (United States)

    Klig, Jean E

    2008-02-01

    The human eye, as an organ, can offer critical clues to the presence of systemic disease. This article discusses the various ophthalmologic manifestations of systemic disease that can be evident on examination by an emergency department provider, as well as some findings that can be discerned with specialty consultation. The following topics are reviewed with respect to potential ocular signs and complications: syphilis, herpes zoster, Lyme disease, acquired immunodeficiency syndrome, Reiter's syndrome, Kawasaki's disease, temporal arteritis, endocarditis, hypertension, and diabetes mellitus. Indications for emergent ophthalmologic consultation are also emphasized.

  5. Computer Tomography: A Novel Diagnostic Technique used in Horses

    African Journals Online (AJOL)

    In Veterinary Medicine, Computer Tomography (CT scan) is used more often in dogs and cats than in large animals due to their small size and ease of manipulation. This paper, however, illustrates the use of the technique in horses. CT scan was used in the diagnosis of two conditions of the head and limbs, namely alveolar ...

  6. Neuro-ophthalmology | Bekibele | Nigerian Journal of Ophthalmology

    African Journals Online (AJOL)

    Transactions of the Ophthalmological Society of Nigeria: Proceedings of the annual OSN Conference, Jos, Nigeria, August 25–28, 2015. Full Text: EMAIL FREE FULL TEXT EMAIL FREE FULL TEXT · DOWNLOAD FULL TEXT DOWNLOAD FULL TEXT · AJOL African Journals Online. HOW TO USE AJOL... for Researchers ...

  7. Unbiased stereologic techniques for practical use in diagnostic histopathology

    DEFF Research Database (Denmark)

    Sørensen, Flemming Brandt

    1995-01-01

    Grading of malignancy by the examination of morphologic and cytologic details in histologic sections from malignant neoplasms is based exclusively on qualitative features, associated with significant subjectivity, and thus rather poor reproducibility. The traditional way of malignancy grading may...... by introducing quantitative techniques in the histopathologic discipline of malignancy grading. Unbiased stereologic methods, especially based on measurements of nuclear three-dimensional mean size, have during the last decade proved their value in this regard. In this survey, the methods are reviewed regarding...... the basic technique involved, sampling, efficiency, and reproducibility. Various types of cancers, where stereologic grading of malignancy has been used, are reviewed and discussed with regard to the development of a new objective and reproducible basis for carrying out prognosis-related malignancy grading...

  8. Diagnostic analysis of vibration signals using adaptive digital filtering techniques

    Science.gov (United States)

    Jewell, R. E.; Jones, J. H.; Paul, J. E.

    1983-01-01

    Signal enhancement techniques are described using recently developed digital adaptive filtering equipment. Adaptive filtering concepts are not new; however, as a result of recent advances in microprocessor-based electronics, hardware has been developed that has stable characteristics and of a size exceeding 1000th order. Selected data processing examples are presented illustrating spectral line enhancement, adaptive noise cancellation, and transfer function estimation in the presence of corrupting noise.

  9. Development of fault diagnostic technique using reactor noise analysis

    International Nuclear Information System (INIS)

    Park, Jin Ho; Kim, J. S.; Oh, I. S.; Ryu, J. S.; Joo, Y. S.; Choi, S.; Yoon, D. B.

    1999-04-01

    The ultimate goal of this project is to establish the analysis technique to diagnose the integrity of reactor internals using reactor noise. The reactor noise analyses techniques for the PWR and CANDU NPP(Nuclear Power Plants) were established by which the dynamic characteristics of reactor internals and SPND instrumentations could be identified, and the noise database corresponding to each plant(both Korean and foreign one) was constructed and compared. Also the change of dynamic characteristics of the Ulchin 1 and 2 reactor internals were simulated under presumed fault conditions. Additionally portable reactor noise analysis system was developed so that real time noise analysis could directly be able to be performed at plant site. The reactor noise analyses techniques developed and the database obtained from the fault simulation, can be used to establish a knowledge based expert system to diagnose the NPP's abnormal conditions. And the portable reactor noise analysis system may be utilized as a substitute for plant IVMS(Internal Vibration Monitoring System). (author)

  10. Development of fault diagnostic technique using reactor noise analysis

    Energy Technology Data Exchange (ETDEWEB)

    Park, Jin Ho; Kim, J. S.; Oh, I. S.; Ryu, J. S.; Joo, Y. S.; Choi, S.; Yoon, D. B

    1999-04-01

    The ultimate goal of this project is to establish the analysis technique to diagnose the integrity of reactor internals using reactor noise. The reactor noise analyses techniques for the PWR and CANDU NPP(Nuclear Power Plants) were established by which the dynamic characteristics of reactor internals and SPND instrumentations could be identified, and the noise database corresponding to each plant(both Korean and foreign one) was constructed and compared. Also the change of dynamic characteristics of the Ulchin 1 and 2 reactor internals were simulated under presumed fault conditions. Additionally portable reactor noise analysis system was developed so that real time noise analysis could directly be able to be performed at plant site. The reactor noise analyses techniques developed and the database obtained from the fault simulation, can be used to establish a knowledge based expert system to diagnose the NPP's abnormal conditions. And the portable reactor noise analysis system may be utilized as a substitute for plant IVMS(Internal Vibration Monitoring System). (author)

  11. Ophthalmologic identification of cerebral malaria in adults

    Directory of Open Access Journals (Sweden)

    Pedrosa, Catarina Areias

    2015-11-01

    Full Text Available Objective: To report the clinical presentation of malarial retinopathy in an adult, emphasizing the importance of this diagnosis for the clinical suspicion and prognosis of cerebral malaria. Methods: A 39-year-old caucasian man presented with hemolytic anemia, thrombocytopenia, acidemia and acute renal failure, developing severe encephalopathy. The diagnosis of malaria was done and after systemic stabilization, the patient noticed a central scotoma in the left eye. Ophthalmological examination revealed retinal features of malarial retinopathy. Results: At one-month follow-up, the patient had improved his systemic condition and the left eye scotoma had disappeared. Visual acuity was 20/20 in both eyes and on examination almost all lesions had regressed. Conclusion: Malarial retinopathy is a diagnostic factor and a prognosis indicator of severe infection, usually with brain involvement. The knowledge of the ophthalmological features associated with severe malaria, which is more frequent in children but can also occur in adults, becomes imperative in order to reduce the risk of neurologic sequelae and associated mortality.

  12. Diagnostics of gas behind shock waves by refractive optical techniques

    International Nuclear Information System (INIS)

    Blaha, J.

    In a brief outline of optical methods for measuring neutral gas and plasma parameters, techniques are specifically dealt with based on the interferometric measurement of the refractive index. The investigation is shown of gas density changes in a shock tube using the optical Mach-Zehnder interferometer. While in a neutral gas the refractive index is determined by gas density, in a plasma the effects of all components, ie., electrons, ions and atoms are additive. The contributions to refraction from the various components may, in view of the different character and frequencies of the components, be resolved by measurement on more than one wavelength. (J.U.)

  13. Analysis of diagnostic calorimeter data by the transfer function technique

    Energy Technology Data Exchange (ETDEWEB)

    Delogu, R. S., E-mail: rita.delogu@igi.cnr.it; Pimazzoni, A.; Serianni, G. [Consorzio RFX, Corso Stati Uniti, 35127 Padova (Italy); Poggi, C.; Rossi, G. [Università degli Studi di Padova, Via 8 Febbraio 1848, 35122 Padova (Italy)

    2016-02-15

    This paper describes the analysis procedure applied to the thermal measurements on the rear side of a carbon fibre composite calorimeter with the purpose of reconstructing the energy flux due to an ion beam colliding on the front side. The method is based on the transfer function technique and allows a fast analysis by means of the fast Fourier transform algorithm. Its efficacy has been tested both on simulated and measured temperature profiles: in all cases, the energy flux features are well reproduced and beamlets are well resolved. Limits and restrictions of the method are also discussed, providing strategies to handle issues related to signal noise and digital processing.

  14. The influence on finite measurement accuracy on the SWE-to-PWE antenna diagnostics technique

    DEFF Research Database (Denmark)

    Cappellin, Cecilia; Breinbjerg, Olav; Frandsen, Aksel

    2006-01-01

    A new antenna diagnostics technique based on the transformation of the spherical wave expansion (SWE) into the plane wave expansion (PWE) is proposed. The new technique allows the recovery of the plane wave spectrum in the visible region, and in principle also in part of the invisible region, from...

  15. Diagnostics of detector tube impacting with wavelet techniques

    Energy Technology Data Exchange (ETDEWEB)

    Racz, A. [KFKI-AEKI Applied Reactor Physics, Budapest (Hungary); Pazsit, I. [Chalmers Univ. of Tech., Goeteborg (Sweden). Dept. of Reactor Physics

    1997-12-08

    A neutron noise based method is proposed for the detection of impacting of detector tubes in BWRs. The basic idea relies on the assumption that non-stationary transients (e.g. fuel box vibrations) may be induced at impacting. Such short-lived transients are difficult to detect by spectral analysis methods. However, their presence in the detector signal can be detected by wavelet analysis. A simple wavelet technique, the so-called Haar transform, is suggested for the detection of impacting. Tests of the proposed method have been performed with success on both simulated data with controlled impacting as well as with real measurement data. The simulation model as well as the results of the wavelet analysis are reported in this paper. The source code written in MATLAB are available at a public ftp site. The necessary information to reproduce the simulation results is also reported. (author).

  16. Diagnostics of detector tube impacting with wavelet techniques

    Energy Technology Data Exchange (ETDEWEB)

    Racz, A.; Pazsit, I

    1998-04-01

    A neutron noise based method is proposed for the detection of impacting of detector tubes in BWRs. The basic idea relies on the assumption that non-stationary transients (e.g. fuel box vibrations) may be induced at impacting. Such short-lived transients are difficult to detect by spectral analysis methods. However, their presence in the detector signal can be detected by wavelet analysis. A simple wavelet technique, the so-called Haar transform, is suggested for the detection of impacting. Tests of the proposed method have been performed with success on both simulated data with controlled impacting as well as with real measurement data. The simulation model as well as the results of the wavelet analysis are reported in this paper. The source codes written in MATLAB[reg] are available at a public ftp site. The necessary information to reproduce the simulation results is also reported.

  17. Mild cognitive impairment. Diagnostic value of different MR techniques

    International Nuclear Information System (INIS)

    Hauser, T.; Stieltjes, B.; Essig, M.; Thomann, P.A.

    2011-01-01

    In view of an increasingly aging population the prevalence of dementia is also expected to increase rapidly. As well as clinical, neuropsychological and laboratory procedures magnetic resonance imaging (MRI) plays an important role in the early diagnosis of dementia which is important in the precursor stage of mild cognitive impairment (MCI). On the one hand this stage is associated with an increased risk of dementia and on the other hand an early treatment in this stage could attenuate development of the disease. In addition to morphological changes different functional MRI techniques can help in the early diagnosis of dementia and the precursor stages. Moreover, it is important to detect those MCI patients who are at particularly risk for developing dementia. In the differentiation of converters to non-converters initial studies suggest that particularly voxel-based morphometry, MR spectroscopy and diffusion tensor imaging can provide important additional information. (orig.) [de

  18. Unbiased stereologic techniques for practical use in diagnostic histopathology

    DEFF Research Database (Denmark)

    Sørensen, Flemming Brandt

    1995-01-01

    by introducing quantitative techniques in the histopathologic discipline of malignancy grading. Unbiased stereologic methods, especially based on measurements of nuclear three-dimensional mean size, have during the last decade proved their value in this regard. In this survey, the methods are reviewed regarding......Grading of malignancy by the examination of morphologic and cytologic details in histologic sections from malignant neoplasms is based exclusively on qualitative features, associated with significant subjectivity, and thus rather poor reproducibility. The traditional way of malignancy grading may...... of solid tumors. This new, unbiased attitude to malignancy grading is associated with excellent virtues, which ultimately may help the clinician in the choice of optimal treatment of the individual patient suffering from cancer. Stereologic methods are not solely applicable to the field of malignancy...

  19. Valve Calcification in Aortic Stenosis: Etiology and Diagnostic Imaging Techniques

    Directory of Open Access Journals (Sweden)

    María Manuela Izquierdo-Gómez

    2017-01-01

    Full Text Available Aortic stenosis is the most common valvulopathy in the Western world. Its prevalence has increased significantly in recent years due to population aging; hence, up to 8% of westerners above the age of 84 now have severe aortic stenosis (Lindroos et al., 1993. This causes increased morbidity and mortality and therein lies the importance of adequate diagnosis and stratification of the degree of severity which allows planning the best therapeutic option in each case. Long understood as a passive age-related degenerative process, it is now considered a rather more complex entity involving mechanisms and factors similar to those of atherosclerosis (Stewart et al., 1997. In this review, we summarize the pathophysiological mechanisms underlying the onset and progression of the disease and analyze the current role of cardiac imaging techniques for diagnosis.

  20. [THE CYTOMETRIC TECHNIQUE OF BINDING OF EOSIN-5-MALEIMIDE IN DIAGNOSTIC OF INHERENT SPHEROCYTOSIS].

    Science.gov (United States)

    Kuzminova, J A; Plyasunova, S A; Jogov, V V; Smetanina, N S

    2016-03-01

    The laboratory diagnostic of inherent spherocytosis is based on detection of spherocytes in peripheral blood, decreasing of index of sphericity, decreasing of osmotic resistance of erythrocytes. The new test of diagnostic of hereditary spherocytosis build on molecular defect was developed on the basis of binding extracellular fragments of protein of band 3 with eosin-5-maleimide (EMA-test). The study was carried out to implement comparative analysis of sensitivity and specificity of techniques applied to diagnose inherent spherocytosis. The sampling of 94 patients with various forms of anemias was analyzed All patients were applied complex clinical laboratory examination including analysis of osmotic resistance of erythrocytes, erythrocytometry and EMA-test as specific techniques of diagnostic of inherent spherocytosis. In 51 out of 94 patients (54%) decreasing of values of EMA-test was detected and in 47 patients diagnosis of inherent spherocytosis was confirmed. The standard values of EMA-test were established in 43 patients (46%) and 12 patients out of them with established diagnosis of inherent spherocytosis. Therefore, sensitivity of EMA-test made up to 79% and specificity - 80%. The most sensitive techniques of diagnostic remain osmotic resistance of erythrocytes (91%) and index of sphericity (up to 96%). But the highest specificity in this respect has EMA-test (80%). Nowadays, none of implemented techniques of diagnostic of inherent spherocytosis can be applied as a universal one. The implementation of complex examination is needed for proper diagnostic of disease.

  1. The pulses as a diagnostic technique in the sun

    International Nuclear Information System (INIS)

    Das, G.C.

    1980-01-01

    In this paper we discuss a method of finding physical parameters by studying the pulses in the Sun. For the sake of a mathematical approach, we consider an ideal, highly relevant model which could exist in the Sun with the effects of ionization, due to which there will be a continuous formation of ionized particles. It is observed that the pulse originated at the centre of a dipole field propagates along the magnetic field. We derive a dispersion relation for these types of pulses, propagating from the centre to the solar surface. The time taken by the pulse from its source to the solar surface is also estimated, with due account of the ionization effects on the pulse. Without proper account of these effects, the technique employed in determing the physical parameters may lead to error. Temporal and spatial damping of the pulses lead to estimates of the velocity distribution of the ionized particles and of the amplitude of the magnetic field of the wave in pulse. (orig.)

  2. Proton current measurements using the prompt gamma ray diagnostic technique

    International Nuclear Information System (INIS)

    Leeper, R.J.; Burns, E.J.T.; Johnson, D.J.; McMurtry, W.M.

    1981-01-01

    Prompt gamma ray signals from the nuclear reaction 7 Li(p,γ) 8 Be have been used to make time resolved proton current measurements. In these measurements, the proton beam was allowed to strike cylindrical thick lithium metal targets. The time integrated proton current was measured using gamma activation of copper via the reaction 63 Cu(γ,n) 62 Cu(β+). The positron activity of the copper sample was easily measured using coincidence counting techniques. The number of 62 Cu atoms produced per proton incident on a thick Li metal target was determined with separate calibration runs performed on the Sandia 2.5 MeV Van de Graaff accelerator. The time history of the prompt gamma production was measured using six EGG NPM-54 scintillator photomultiplier combinations shielded by 96.5 cm of concrete and 5.1 cm of Pb. The use of six scintillator photomultiplier combinations was necessary to increase the statistical precision of the data. The normalization of the prompt gamma time history data with the total time integrated proton-current measurement yielded the absolute time resolved proton current on target. Data from runs performed on the Sandia Proto I accelerator will be presented

  3. Review of Physicochemical-Based Diagnostic Techniques for Assessing Insulation Condition in Aged Transformers

    Directory of Open Access Journals (Sweden)

    Janvier Sylvestre N’cho

    2016-05-01

    Full Text Available A power transformer outage has a dramatic financial consequence not only for electric power systems utilities but also for interconnected customers. The service reliability of this important asset largely depends upon the condition of the oil-paper insulation. Therefore, by keeping the qualities of oil-paper insulation system in pristine condition, the maintenance planners can reduce the decline rate of internal faults. Accurate diagnostic methods for analyzing the condition of transformers are therefore essential. Currently, there are various electrical and physicochemical diagnostic techniques available for insulation condition monitoring of power transformers. This paper is aimed at the description, analysis and interpretation of modern physicochemical diagnostics techniques for assessing insulation condition in aged transformers. Since fields and laboratory experiences have shown that transformer oil contains about 70% of diagnostic information, the physicochemical analyses of oil samples can therefore be extremely useful in monitoring the condition of power transformers.

  4. A Hybrid Neural Network-Genetic Algorithm Technique for Aircraft Engine Performance Diagnostics

    Science.gov (United States)

    Kobayashi, Takahisa; Simon, Donald L.

    2001-01-01

    In this paper, a model-based diagnostic method, which utilizes Neural Networks and Genetic Algorithms, is investigated. Neural networks are applied to estimate the engine internal health, and Genetic Algorithms are applied for sensor bias detection and estimation. This hybrid approach takes advantage of the nonlinear estimation capability provided by neural networks while improving the robustness to measurement uncertainty through the application of Genetic Algorithms. The hybrid diagnostic technique also has the ability to rank multiple potential solutions for a given set of anomalous sensor measurements in order to reduce false alarms and missed detections. The performance of the hybrid diagnostic technique is evaluated through some case studies derived from a turbofan engine simulation. The results show this approach is promising for reliable diagnostics of aircraft engines.

  5. Development of technique for diagnostics of social reserves of development of collective labour potential

    OpenAIRE

    Голубєв, Станіслав Миколайович

    2015-01-01

    The problems of diagnostics of social reserves of the collective labour potential are considered in the article. The aim of this study is to develop diagnostic techniques of social reserves of the collective labour potential in the work and the essence of the concept of "social reserves" as a subject of study of economics and their features in the study of collective labour potential. The use of these reserves can increase the efficiency of the labour collective processes by improving coopera...

  6. Case-based reasoning diagnostic technique based on multi-attribute similarity

    Energy Technology Data Exchange (ETDEWEB)

    Makoto, Takahashi [Tohoku University, Miyagi (Japan); Akio, Gofuku [Okayama University, Okayamaa (Japan)

    2014-08-15

    Case-based diagnostic technique has been developed based on the multi-attribute similarity. Specific feature of the developed system is to use multiple attributes of process signals for similarity evaluation to retrieve a similar case stored in a case base. The present technique has been applied to the measurement data from Monju with some simulated anomalies. The results of numerical experiments showed that the present technique can be utilizes as one of the methods for a hybrid-type diagnosis system.

  7. Wavefront Measurement in Ophthalmology

    Science.gov (United States)

    Molebny, Vasyl

    Wavefront sensing or aberration measurement in the eye is a key problem in refractive surgery and vision correction with laser. The accuracy of these measurements is critical for the outcome of the surgery. Practically all clinical methods use laser as a source of light. To better understand the background, we analyze the pre-laser techniques developed over centuries. They allowed new discoveries of the nature of the optical system of the eye, and many served as prototypes for laser-based wavefront sensing technologies. Hartmann's test was strengthened by Platt's lenslet matrix and the CCD two-dimensional photodetector acquired a new life as a Hartmann-Shack sensor in Heidelberg. Tscherning's aberroscope, invented in France, was transformed into a laser device known as a Dresden aberrometer, having seen its reincarnation in Germany with Seiler's help. The clinical ray tracing technique was brought to life by Molebny in Ukraine, and skiascopy was created by Fujieda in Japan. With the maturation of these technologies, new demands now arise for their wider implementation in optometry and vision correction with customized contact and intraocular lenses.

  8. Evaluation of techniques for inspection and diagnostics of HWR pressure tubes

    International Nuclear Information System (INIS)

    Choi, Jong-Ho

    2008-01-01

    Efficient and accurate inspection and diagnostic techniques for various reactor components and systems, especially pressure tubes for Heavy Water Reactors (HWRs), are an important factor in assuring reliable and safe plant operation. To foster international collaboration in the efficient and safe use of nuclear power, the IAEA conducted a Coordinated Research Project (CRP) on Inter-comparison of Techniques for HWR Pressure Tube Inspection and Diagnostics. The objective of the CRP was to inter-compare inspection and diagnostic techniques, in use and being developed, for structural integrity assessment of HWR pressure tubes. During the first phase of the CRP, participants investigated the capability of different techniques to detect and characterize flaws. During the second phase, participants collaborated to determine the hydrogen concentration and to detect and characterize hydride blisters in zirconium alloy pressure tubes. Eight organizations from six countries, which operate HWRs, have participated in this CRP, Most of the techniques examined are well established and many of them are regularly used during in-service inspection of pressure tubes. The inter-comparison of these techniques provides a platform for identifying a particular technique (or a set of techniques), which is more accurate and reliable as compared to others for a specified task. The CRP also witnessed some new methodologies, which can be implemented on in-service inspection tools. These new techniques could complement the existing ones to overcome their limitations, thereby improving the reliability and accuracy of in-service inspection. This CRP also identified future areas of research and development. (author)

  9. Optical coherence tomography--a new imaging method in ophthalmology.

    Science.gov (United States)

    Svorenova, I; Strmen, P; Olah, Z

    2010-01-01

    An improvement of examination methods in ophthalmology, technical digitalisation and knowledge of validity of examinations in various diseases contributes to early diagnostics, thereby leading to an opportunity for early treatment of eye disorders. Standard introduction of the so-called optical coherence tomography into the ophthamological clinical practice facilitated new options for a detailed analysis of pathological processes in the particular layers of the retina (Fig. 2, Ref. 5). Full Text (Free, PDF) www.bmj.sk.

  10. Textbook of focusing techniques in diagnostic radiography. 5. new rev. ed.

    International Nuclear Information System (INIS)

    Bosnjakovic-Buescher, S.; Riegler-Bubeck, C.; Zimmer-Brossy, M.; Bast, B.

    1998-01-01

    This 5th edition of the standard work on focusing techniques in diagnostic radiography is a guide for X-ray medical technicians and radiologists wishing to optimize their skills and produce images of high technical standard and diagnostic value. The major part of the textbook deals with the focusing and imaging techniques for evaluation of the skeleton and inner body organs. The new edition includes the current legal provisions for radiological protection and the latest quality assurance legislation. It is an indispensable source of reference for clinical departments, radiographic practice, and training institutions. (orig./CB) [de

  11. The radiation protection optimisation in contrast X-ray diagnostic techniques

    International Nuclear Information System (INIS)

    Markovic, S.; Pavlovic, R.

    1995-01-01

    In the class of artificial sources, X-ray diagnostic techniques irradiate global population with more than 90 % share in total dose. At the same time this is the only area with high possibilities in collective dose reduction without important investments. Exposure of the medical team is mainly related to unnecessary irradiation. Eliminating this unnecessary irradiation quality of diagnostic information remains undisturbed. From the radiation protection point of view the most critical X-ray diagnostic method is angiography. This paper presents the radiation protection optimisation calculation of the protective lead thickness using the Cost - Benefit analysis technique. The obtained numerical results are based on calculated collective dose, the estimated prices of the lead and lead glass thickness and the adopted price for monetary value of the collective dose unit α. (author) 3 figs., 10 refs

  12. The radiation protection optimisation in contrast X-ray diagnostic techniques

    Energy Technology Data Exchange (ETDEWEB)

    Markovic, S; Pavlovic, R [Inst. of Nuclear Science Vinca, Belgrade (Yugoslavia). Radiation and Environmental Protection Lab.; Boreli, F [Fac. of Electrical Engineering, Belgrade (Yugoslavia)

    1996-12-31

    In the class of artificial sources, X-ray diagnostic techniques irradiate global population with more than 90 % share in total dose. At the same time this is the only area with high possibilities in collective dose reduction without important investments. Exposure of the medical team is mainly related to unnecessary irradiation. Eliminating this unnecessary irradiation quality of diagnostic information remains undisturbed. From the radiation protection point of view the most critical X-ray diagnostic method is angiography. This paper presents the radiation protection optimisation calculation of the protective lead thickness using the Cost - Benefit analysis technique. The obtained numerical results are based on calculated collective dose, the estimated prices of the lead and lead glass thickness and the adopted price for monetary value of the collective dose unit {alpha}. (author) 3 figs., 10 refs.

  13. The application of DECnet TTT technique in beam diagnostical system of SSC central region

    International Nuclear Information System (INIS)

    Zhang Guixu; Huang Tuanhua

    1997-01-01

    The DECnet TTT technique and the real time network communication based on DECnet TTT are presented. Information can be transferred between console and diagnostical system via DECnet communication, so all kinds of operation can be done on console. The working computer of HIRFL console is VAX8350

  14. New perineal injection technique for pudendal nerve infiltration in diagnostic and therapeutic procedures

    NARCIS (Netherlands)

    Weinschenk, Stefan; Hollmann, Markus W.; Strowitzki, Thomas

    2016-01-01

    Pudendal nerve injection is used as a diagnostic procedure in the vulvar region and for therapeutic purposes, such as in vulvodynia. Here, we provide a new, easy-to-perform perineal injection technique. We analyzed 105 perineal injections into the pudendal nerve with a local anesthetic (LA),

  15. Intercomparison of techniques for inspection and diagnostics of heavy water reactor pressure tubes. Additional information

    International Nuclear Information System (INIS)

    2009-03-01

    The reports from Argentina, Canada, India, Korea and Romania are presented concerning the projects carried out under the Coordinated Research Program (CRP) I3.30.10 of the International Agency for Atomic Energy - Vienna related to 'Intercomparison of Techniques for Pressure Tube Inspection and Diagnostics'

  16. On-line diagnostic techniques for air-operated control valves based on time series analysis

    International Nuclear Information System (INIS)

    Ito, Kenji; Matsuoka, Yoshinori; Minamikawa, Shigeru; Komatsu, Yasuki; Satoh, Takeshi.

    1996-01-01

    The objective of this research is to study the feasibility of applying on-line diagnostic techniques based on time series analysis to air-operated control valves - numerous valves of the type which are used in PWR plants. Generally the techniques can detect anomalies by failures in the initial stages for which detection is difficult by conventional surveillance of process parameters measured directly. However, the effectiveness of these techniques depends on the system being diagnosed. The difficulties in applying diagnostic techniques to air-operated control valves seem to come from the reduced sensitivity of their response as compared with hydraulic control systems, as well as the need to identify anomalies in low level signals that fluctuate only slightly but continuously. In this research, simulation tests were performed by setting various kinds of failure modes for a test valve with the same specifications as of a valve actually used in the plants. Actual control signals recorded from an operating plant were then used as input signals for simulation. The results of the tests confirmed the feasibility of applying on-line diagnostic techniques based on time series analysis to air-operated control valves. (author)

  17. An Aid to Neuro-Ophthalmology

    OpenAIRE

    Akram, Muhammad

    2011-01-01

    Muhammad Shoaib AkramDepartment of Ophthalmology, King Fahad Military Hospital, Khamis Mushyat, Saudi ArabiaNeuro-ophthalmology is a very interesting field. Localizing a lesion in various pathways can be challenging, particularly for beginners. One needs a solid foundation of the neuro-anatomy of visual pathways to enhance understanding. The author aims to provide medical students and residents with the basic concepts of neuro-ophthalmology. This text attempts to simplify the complex problems...

  18. Advanced Laser-Based Techniques for Gas-Phase Diagnostics in Combustion and Aerospace Engineering.

    Science.gov (United States)

    Ehn, Andreas; Zhu, Jiajian; Li, Xuesong; Kiefer, Johannes

    2017-03-01

    Gaining information of species, temperature, and velocity distributions in turbulent combustion and high-speed reactive flows is challenging, particularly for conducting measurements without influencing the experimental object itself. The use of optical and spectroscopic techniques, and in particular laser-based diagnostics, has shown outstanding abilities for performing non-intrusive in situ diagnostics. The development of instrumentation, such as robust lasers with high pulse energy, ultra-short pulse duration, and high repetition rate along with digitized cameras exhibiting high sensitivity, large dynamic range, and frame rates on the order of MHz, has opened up for temporally and spatially resolved volumetric measurements of extreme dynamics and complexities. The aim of this article is to present selected important laser-based techniques for gas-phase diagnostics focusing on their applications in combustion and aerospace engineering. Applicable laser-based techniques for investigations of turbulent flows and combustion such as planar laser-induced fluorescence, Raman and Rayleigh scattering, coherent anti-Stokes Raman scattering, laser-induced grating scattering, particle image velocimetry, laser Doppler anemometry, and tomographic imaging are reviewed and described with some background physics. In addition, demands on instrumentation are further discussed to give insight in the possibilities that are offered by laser flow diagnostics.

  19. Imaging nuclear medicine techniques for diagnostic evaluation of arterial hypertension. Bildgebende nuklearmedizinische Diagnostik bei arterieller Hypertonie

    Energy Technology Data Exchange (ETDEWEB)

    Eisenberg, B M; Linss, G

    1989-01-01

    Arterial hypertension may be caused by a malfunction of organs and in turn may lead to secondary organic lesions. Modern diagnostic nuclear medicine is applied for function studies in order to detect or exclude secondary hypertension and functional or perfusion disturbances due to hypertension, or to assess and follow up hemodynamic conditions and cardiac functions prior to and during therapy. The article presents a survey of imaging diagnostic nuclear medicine techniques for the eamination of the heart, the brain, the kidneys and endocrine glands in patients with arterial hypertension, discussing the methods with a view to obtainable information, limits of detection, and indications. (orig.).

  20. Foundation of the American Academy of Ophthalmology

    Science.gov (United States)

    ... Plastic Surgery Center Laser Surgery Education Center Redmond Ethics Center Global Ophthalmology Guide Eye ... and Planned Giving Ophthalmic Business Council Orbital Gala Orbital Gala Overview Why Attend ...

  1. ICF implosion hotspot ion temperature diagnostic techniques based on neutron time-of-flight method

    International Nuclear Information System (INIS)

    Tang Qi; Song Zifeng; Chen Jiabin; Zhan Xiayu

    2013-01-01

    Ion temperature of implosion hotspot is a very important parameter for inertial confinement fusion. It reflects the energy level of the hotspot, and it is very sensitive to implosion symmetry and implosion speed. ICF implosion hotspot ion temperature diagnostic techniques based on neutron time-of-flight method were described. A neutron TOF spectrometer was developed using a ultrafast plastic scintillator as the neutron detector. Time response of the spectrometer has 1.1 ns FWHM and 0.5 ns rising time. TOF spectrum resolving method based on deconvolution and low pass filter was illuminated. Implosion hotspot ion temperature in low neutron yield and low ion temperature condition at Shenguang-Ⅲ facility was acquired using the diagnostic techniques. (authors)

  2. Electrical-Based Diagnostic Techniques for Assessing Insulation Condition in Aged Transformers

    Directory of Open Access Journals (Sweden)

    Issouf Fofana

    2016-08-01

    Full Text Available The condition of the internal cellulosic paper and oil insulation are of concern for the performance of power transformers. Over the years, a number of methods have been developed to diagnose and monitor the degradation/aging of the transformer internal insulation system. Some of this degradation/aging can be assessed from electrical responses. Currently there are a variety of electrical-based diagnostic techniques available for insulation condition monitoring of power transformers. In most cases, the electrical signals being monitored are due to mechanical or electric changes caused by physical changes in resistivity, inductance or capacitance, moisture, contamination or aging by-products in the insulation. This paper presents a description of commonly used and modern electrical-based diagnostic techniques along with their interpretation schemes.

  3. MR cholangiopancreatography: prospective comparison of a breath-hold 2D projection technique with diagnostic ERCP

    International Nuclear Information System (INIS)

    Lomas, D.J.; Bearcroft, P.W.P.; Gimson, A.E.

    1999-01-01

    The aim of this study was to compare prospectively a breath-hold projection magnetic resonance cholangiopancreatography (MRCP) technique with diagnostic endoscopic retrograde cholangiopancreatography (ERCP). Seventy-six patients with suspected strictures or choledocholithiasis were referred for MRCP and subsequent ERCP examination, which were performed within 4 h of each other. The MRCP technique was performed using fat-suppressed rapid acquisition with relaxation enhancement (RARE) projection images obtained in standardised planes with additional targeted projections as required by the supervising radiologist. Two radiologists (in consensus) assessed the MRCP results prospectively and independently for the presence of bile duct calculi, strictures, non-specific biliary dilatation and pancreatic duct dilatation, and recorded a single primary diagnosis. The ERCP was assessed prospectively and independently by a single endoscopist and used as a gold standard for comparison with MRCP. Diagnostic agreement was assessed by the Kappa statistic. The MRCP technique failed in two patients and ERCP in five. In the remaining 69 referrals ERCP demonstrated normal findings in 23 cases, strictures in 19 cases, choledocholithiasis in 9 cases, non-specific biliary dilatation in 14 cases and chronic pancreatitis in 4 cases. The MRCP technique correctly demonstrated 22 of 23 normal cases, 19 strictures with one false positive (sensitivity 100 %, specificity 98 %), all 9 cases of choledocholithiasis with two false positives (sensitivity 100 %, specificity 97 %), 12 of 14 cases of non-specific biliary dilatation and only 1 of 4 cases of chronic pancreatitis. There was overall good agreement for diagnosis based on a kappa value of 0.88. Breath-hold projection MRCP can provide non-invasively comparable diagnostic information to diagnostic ERCP for suspected choledocholithiasis and biliary strictures and may allow more selective use of therapeutic ERCP. (orig.)

  4. Plasma diagnostic techniques in thermal-barrier tandem-mirror fusion experiments

    International Nuclear Information System (INIS)

    Silver, E.H.; Clauser, J.F.; Carter, M.R.; Failor, B.H.; Foote, J.H.; Hornady, R.S.; James, R.A.; Lasnier, C.J.; Perkins, D.E.

    1986-01-01

    We review two classes of plasma diagnostic techniques used in thermal-barrier tandem-mirror fusion experiments. The emphasis of the first class is to study mirror-trapped electrons at the thermal-barrier location. The focus of the second class is to measure the spatial and temporal behavior of the plasma space potential at various axial locations. The design and operation of the instruments in these two categories are discussed and data that are representative of their performance is presented

  5. The evaluation of the irradiation of medical team in critical X-ray diagnostic techniques

    Energy Technology Data Exchange (ETDEWEB)

    Markovic, S; Pavlovic, R [Inst. of Nuclear Science Vinca, Belgrade (Yugoslavia). Radiation and Environmental Protection Lab.; Boreli, F [Fac. of Electrical Engineering, Belgrade (Yugoslavia)

    1996-12-31

    A good realized assessment of the irradiation for any exposed group of population serves as the base for the radiation protection measures (emergency radiation preparedness, radiation protection optimization etc.). This is especially important, by the radiation protection point of view, in contrast X-ray diagnostic techniques - angiographies. This paper presents the way for the realization of the medical team irradiation assessment, based on originally derived simple equations for the scattered radiation field around patient. (author) 1 fig., 3 figs.

  6. Ophthalmologic abnormalities among deaf students in Kaduna ...

    African Journals Online (AJOL)

    ... syndrome (0.6%) and Ushers syndrome (0.6%). Refractive error was the most common (7.9%). Conclusion: Since these deaf students use their sight to compensate for the deafness, routine ophthalmologic examination should be carried out on them so that ophthalmologic abnormalities are detected early and treatment ...

  7. The application of laser plasma in ophthalmology

    International Nuclear Information System (INIS)

    He Yujiang; Luo Le; Sun Yabing

    2000-01-01

    The production and development of laser plasma are introduced, and the contribution of laser biomedicine and laser plasma technology to ophthalmology is analyzed. The latest three progresses (laser photocoagulation, photo-refractive keratotomy and laser iridectomy) of laser plasma applications in ophthalmology are presented

  8. Optical diagnostics of vascular reactions triggered by weak allergens using laser speckle-contrast imaging technique

    International Nuclear Information System (INIS)

    Kuznetsov, Yu L; Kalchenko, V V; Astaf'eva, N G; Meglinski, I V

    2014-01-01

    The capability of using the laser speckle contrast imaging technique with a long exposure time for visualisation of primary acute skin vascular reactions caused by a topical application of a weak contact allergen is considered. The method is shown to provide efficient and accurate detection of irritant-induced primary acute vascular reactions of skin. The presented technique possesses a high potential in everyday diagnostic practice, preclinical studies, as well as in the prognosis of skin reactions to the interaction with potentially allergenic materials. (laser biophotonics)

  9. Optical diagnostics of vascular reactions triggered by weak allergens using laser speckle-contrast imaging technique

    Energy Technology Data Exchange (ETDEWEB)

    Kuznetsov, Yu L; Kalchenko, V V [Department of Veterinary Resources, Weizmann Institute of Science, Rehovot, 76100 (Israel); Astaf' eva, N G [V.I.Razumovsky Saratov State Medical University, Saratov (Russian Federation); Meglinski, I V [N.G. Chernyshevsky Saratov State University, Saratov (Russian Federation)

    2014-08-31

    The capability of using the laser speckle contrast imaging technique with a long exposure time for visualisation of primary acute skin vascular reactions caused by a topical application of a weak contact allergen is considered. The method is shown to provide efficient and accurate detection of irritant-induced primary acute vascular reactions of skin. The presented technique possesses a high potential in everyday diagnostic practice, preclinical studies, as well as in the prognosis of skin reactions to the interaction with potentially allergenic materials. (laser biophotonics)

  10. Ophthalmology research protocol, Hiroshima - Nagasaki

    Energy Technology Data Exchange (ETDEWEB)

    Miller, R J; Fujino, Tadashi; Nefzger, M D

    1964-05-21

    Several large ophthalmic studies have been made at ABCC. However, all preceded the final identification and definition of the Master Sample which unifies the three present major research studies, and T57D estimates were not available. For these reasons it seemed highly desirable to undertake another ophthalmic study which would both relate to the present program and utilize available dose information. Consequently, in 1962 a consultant in ophthalmology, Dr. P.J. Leinfelder visited ABCC to acquaint himself with the ABCC program and facilities, and he prepared the broad plan for this study. The present document describes the detailed working program which developed from this initial plan. For the period 1963 to 1964, investigation will be directed towards detection and evaluation of the following possible late effects of exposure to ionizing radiation: lens opacities; accelerated aging; and decreased acuity. 43 references, 1 figure, 4 tables.

  11. Optimized design of shields for diagnostic X rays with NCRP 147 technique

    International Nuclear Information System (INIS)

    Gama T, G.

    2006-01-01

    A comparison among the design techniques of shielding for X-ray diagnostic rooms with the NCRP 49 (1976) report technique, AAPM 39 (1993) Y the one of the NCRP 147 (2005) technique. The designs correspond to a room of conventional X-rays, one of fluoroscopy, one of tomography Y one of mammography. In all the cases it demonstrates that the NCRP 49 technique overestimate the shieldings. The causes of the overestimation of the NCRP 49 can be attributed to: a) high values of the work charge that don't consider the spectral fluence of the photons that are present in each room, b) to the differences in the values of the kerma in air without attenuation for the dispersed primary radiation Y of leakage among both reports. (Author)

  12. Consideration on the diagnostic ability of various imaging techniques in relation to renal tumor

    International Nuclear Information System (INIS)

    Ike, Katsushi

    1984-01-01

    Radiological diagnosis of renal tumors is being improved with the increased imaging accuracy which has resulted from advancement in the various equipment used and improvement in techniques. However, at the clinical level, diagnostic procedures based on the characteristics of the delineated images are not yet established and the diverse diagnostic procedures are being conducted currently in a stereotyped manner. In this study, the images of 61 cases diagnosed as renal tumor were analysed retrospectively with the purpose of establishing the imaging accuracy, capacity for diagnosis based on image characteristics and a subseguent proper diagnostic procedure. It was found that CT and Angio gave similar diagnostic accuracy. It was further revealed that US images enabled to differentiate renal tumors from the more commonly experienced renal cystic disease. For determination of tunica involucrum infiltration, which is essential to diagnose Stage I and II renal tumors, CT was proved to be superior to Angio. CT and US were also to be so in the determination of metastasis to para-aortic lymph nodes which is a Stage III criterion. In recent years, CT and US imaging accuracies have increased, hence the improvement in the capacity to diagnose non-observable renal tumors is highly expected. (author)

  13. TOF technique for laser-driven proton beam diagnostics for the ELIMED beamline

    International Nuclear Information System (INIS)

    Milluzzo, G.; Scuderi, V.; Amico, A.G.; Cirrone, G.A.P.; Cuttone, G.; Larosa, G.; Leanza, R.; Petringa, G.; Pipek, J.; Romano, F.; Napoli, M. De; Dostal, J.; Margarone, D.; Schillaci, F.; Velyhan, A.

    2017-01-01

    The Time of Flight (TOF) method for laser-driven ion beam diagnostics has been extensively investigated so far for low energy ion diagnostics and several works, reported in literature [1,2], have shown its efficiency in the measurement of particle beam characteristics such as ion species, energy spectrum and current. Moreover, such technique allows obtaining a shot-to-shot on-line monitoring of optically accelerated particles, necessary to control the reproducibility of the accelerated beam and to deliver a beam suitable for any kind of applications. For this reason, the ELIMED beamline [3,4], which will be entirely developed at INFN-LNS and installed in 2017 within the ion beamline ELIMAIA (ELI Multidisciplinary Applications of laser-Ion Acceleration) experimental hall at ELI-Beamlines in Prague, will be equipped with an on-line diagnostics system composed by silicon carbide and diamond detectors, using the TOF technique. In this contribution, the procedure developed for TOF signal analysis will be briefly reported.

  14. Vibration monitoring/diagnostic techniques, as applied to reactor coolant pumps

    International Nuclear Information System (INIS)

    Sculthorpe, B.R.; Johnson, K.M.

    1986-01-01

    With the increased awareness of reactor coolant pump (RCP) cracked shafts, brought about by the catastrophic shaft failure at Crystal River number3, Florida Power and Light Company, in conjunction with Bently Nevada Corporation, undertook a test program at St. Lucie Nuclear Unit number2, to confirm the integrity of all four RCP pump shafts. Reactor coolant pumps play a major roll in the operation of nuclear-powered generation facilities. The time required to disassemble and physically inspect a single RCP shaft would be lengthy, monetarily costly to the utility and its customers, and cause possible unnecessary man-rem exposure to plant personnel. When properly applied, vibration instrumentation can increase unit availability/reliability, as well as provide enhanced diagnostic capability. This paper reviews monitoring benefits and diagnostic techniques applicable to RCPs/motor drives

  15. PREFACE: IX International Conference on Modern Techniques of Plasma Diagnostics and their Application

    Science.gov (United States)

    Savjolov, A. S.; Dodulad, E. I.

    2016-01-01

    The IX Conference on ''Modern Techniques of Plasma Diagnosis and their Application'' was held on 5 - 7 November, 2014 at National Research Nuclear University MEPhI (NRNU MEPhI). The goal of the conference was an exchange of information on both high-temperature and low-temperature plasma diagnostics as well as deliberation and analysis of various diagnostic techniques and their applicability in science, industry, ecology, medicine and other fields. The Conference also provided young scientists from scientific centres and universities engaged in plasma diagnostics with an opportunity to attend the lectures given by the leading specialists in this field as well as present their own results and findings. The first workshop titled ''Modern problems of plasma diagnostics and their application for control of chemicals and the environment'' took place at Moscow Engineering and Physics Institute (MEPhI) in June 1998 with the support of the Section on Diagnostics of the Council of Russian Academic of Science on Plasma Physics and since then these forums have been held at MEPhI every two years. In 2008 the workshop was assigned a conference status. More than 150 specialists on plasma diagnostics and students took part in the last conference. They represented leading Russian scientific centres (such as Troitsk Institute of Innovative and Thermonuclear Research, National Research Centre ''Kurchatov Institute'', Russian Federal Nuclear Centre - All-Russian Scientific Research Institute of Experimental Physics and others) and universities from Belarus, Ukraine, Germany, USA, Belgium and Sweden. About 30 reports were made by young researchers, students and post-graduate students. All presentations during the conference were broadcasted online over the internet with viewers in Moscow, Prague, St. Petersburgh and other cities. The Conference was held within the framework of the Centre of Plasma, Laser Research and Technology supported by MEPhI Academic Excellence Project (Russian

  16. Evidence-based medical research on diagnostic criteria and screening technique of vascular mild cognitive impairment

    Directory of Open Access Journals (Sweden)

    Xia-wei LIU

    2015-07-01

    Full Text Available Background Vascular mild cognitive impairment (VaMCI is the prodromal syndrome of vascular dementia (VaD and key target for drug treatment. There is controversy over the diagnostic criteria and screening tools of VaMCI, which affects its clinical diagnosis. This paper aims to explore the clinical features, diagnostic criteria and screening technique of VaMCI.  Methods Taking "vascular mild cognitive impairment OR vascular cognitive impairment no dementia" as retrieval terms, search in PubMed database from January 1997 to March 2015 and screen relevant literatures concerning VaMCI. According to Guidance for the Preparation of Neurological Management Guidelines revised by European Federation of Neurological Societies (EFNS in 2004, evidence grading was performed on literatures. Results A total of 32 literatures in English were selected according to inclusion and exclusion criteria, including 3 guidelines and consensus and 29 clinical studies. Seven literatures (2 on Level Ⅰ, 5 on Level Ⅱ studied on neuropsychological features in VaMCI patients and found reduced processing speed and executive function impairment were main features. Two literatures reported the diagnostic criteria of VaMCI, including VaMCI criteria published by American Heart Association (AHA/American Stroke Association (ASA in 2011 and "Diagnostic Criteria for Vascular Cognitive Disorders" published by International Society for Vascular Behavioral and Cognitive Disorders (VASCOG in 2014. Fifteen literatures (4 on LevelⅠ, 11 on Level Ⅱ described the diagnostic criteria of VaMCI used in clinical research, from which 6 operational diagnostic items were extracted. Fourteen literatures (4 on Level Ⅰ, 10 on Level Ⅱ described neuropsychological assessment tools for VaMCI screening, and found the 5-minute protocol recommended by National Institute of Neurological Disorders and Stroke-Canadian Stroke Network (NINDS-CSN was being good consistency with other neuropsychological

  17. Imaging techniques used in the diagnostic workup of acute venous thromboembolic disease.

    Science.gov (United States)

    Tilve-Gómez, A; Rodríguez-Fernández, P; Trillo-Fandiño, L; Plasencia-Martínez, J M

    Early diagnosis is one of the most important factors affecting the prognosis of pulmonary embolism (PE); however, the clinical presentation of PE is often very unspecific and it can simulate other diseases. For these reasons, imaging tests, especially computed tomography angiography (CTA) of the pulmonary arteries, have become the keystone in the diagnostic workup of PE. The wide availability and high diagnostic performance of pulmonary CTA has led to an increase in the number of examinations done and a consequent increase in the population's exposure to radiation and iodinated contrast material. Thus, other techniques such as scintigraphy and venous ultrasonography of the lower limbs, although less accurate, continue to be used in certain circumstances, and optimized protocols have been developed for CTA to reduce the dose of radiation (by decreasing the kilovoltage) and the dose of contrast agents. We describe the technical characteristics and interpretation of the findings for each imaging technique used to diagnose PE and discuss their advantages and limitations; this knowledge will help the best technique to be chosen for each case. Finally, we comment on some data about the increased use of CTA, its clinical repercussions, its "overuse", and doubts about its cost-effectiveness. Copyright © 2016 SERAM. Publicado por Elsevier España, S.L.U. All rights reserved.

  18. Picosecond high power laser systems and picosecond diagnostic technique in laser produced plasma

    International Nuclear Information System (INIS)

    Kuroda, Hiroto; Masuko, H.; Maekawa, Shigeru; Suzuki, Yoshiji; Sugiyama, Masaru.

    1979-01-01

    Highly repetitive, high power YAG and Glass laser systems have been developed and been successfully used for the studies of laser-plasma interactions. Various picosecond diagnostic techniques have been developed for such purposes in the regions from optical to X-ray frequency. Recently highly sensitive X-ray (1 - 10 KeV) streak camera for highly repetitive operations have been developed. Preliminary experiment shows the achievement of 28ps temporal resolution (100μm slit) and good sensitivity with detectable minimum number of 10E3-1KeV photons/shot/slit area. (author)

  19. Iterative reconstruction technique with reduced volume CT dose index: diagnostic accuracy in pediatric acute appendicitis

    International Nuclear Information System (INIS)

    Didier, Ryne A.; Vajtai, Petra L.; Hopkins, Katharine L.

    2015-01-01

    Iterative reconstruction technique has been proposed as a means of reducing patient radiation dose in pediatric CT. Yet, the effect of such reductions on diagnostic accuracy has not been thoroughly evaluated. This study compares accuracy of diagnosing pediatric acute appendicitis using contrast-enhanced abdominopelvic CT scans performed with traditional pediatric weight-based protocols and filtered back projection reconstruction vs. a filtered back projection/iterative reconstruction technique blend with reduced volume CT dose index (CTDI vol ). Results of pediatric contrast-enhanced abdominopelvic CT scans done for pain and/or suspected appendicitis were reviewed in two groups: A, 192 scans performed with the hospital's established weight-based CT protocols and filtered back projection reconstruction; B, 194 scans performed with iterative reconstruction technique and reduced CTDI vol . Reduced CTDI vol was achieved primarily by reductions in effective tube current-time product (mAs eff ) and tube peak kilovoltage (kVp). CT interpretation was correlated with clinical follow-up and/or surgical pathology. CTDI vol , size-specific dose estimates (SSDE) and performance characteristics of the two CT techniques were then compared. Between groups A and B, mean CTDI vol was reduced by 45%, and mean SSDE was reduced by 46%. Sensitivity, specificity and diagnostic accuracy were 96%, 97% and 96% in group A vs. 100%, 99% and 99% in group B. Accuracy in diagnosing pediatric acute appendicitis was maintained in contrast-enhanced abdominopelvic CT scans that incorporated iterative reconstruction technique, despite reductions in mean CTDI vol and SSDE by nearly half as compared to the hospital's traditional weight-based protocols. (orig.)

  20. Iterative reconstruction technique with reduced volume CT dose index: diagnostic accuracy in pediatric acute appendicitis

    Energy Technology Data Exchange (ETDEWEB)

    Didier, Ryne A. [Oregon Health and Science University, Department of Diagnostic Radiology, DC7R, Portland, OR (United States); Vajtai, Petra L. [Oregon Health and Science University, Department of Pediatrics, Portland, OR (United States); Oregon Health and Science University, Department of Diagnostic Radiology, DC7R, Portland, OR (United States); Hopkins, Katharine L. [Oregon Health and Science University, Department of Diagnostic Radiology, DC7R, Portland, OR (United States); Oregon Health and Science University, Department of Pediatrics, Portland, OR (United States)

    2014-07-05

    Iterative reconstruction technique has been proposed as a means of reducing patient radiation dose in pediatric CT. Yet, the effect of such reductions on diagnostic accuracy has not been thoroughly evaluated. This study compares accuracy of diagnosing pediatric acute appendicitis using contrast-enhanced abdominopelvic CT scans performed with traditional pediatric weight-based protocols and filtered back projection reconstruction vs. a filtered back projection/iterative reconstruction technique blend with reduced volume CT dose index (CTDI{sub vol}). Results of pediatric contrast-enhanced abdominopelvic CT scans done for pain and/or suspected appendicitis were reviewed in two groups: A, 192 scans performed with the hospital's established weight-based CT protocols and filtered back projection reconstruction; B, 194 scans performed with iterative reconstruction technique and reduced CTDI{sub vol}. Reduced CTDI{sub vol} was achieved primarily by reductions in effective tube current-time product (mAs{sub eff}) and tube peak kilovoltage (kVp). CT interpretation was correlated with clinical follow-up and/or surgical pathology. CTDI{sub vol}, size-specific dose estimates (SSDE) and performance characteristics of the two CT techniques were then compared. Between groups A and B, mean CTDI{sub vol} was reduced by 45%, and mean SSDE was reduced by 46%. Sensitivity, specificity and diagnostic accuracy were 96%, 97% and 96% in group A vs. 100%, 99% and 99% in group B. Accuracy in diagnosing pediatric acute appendicitis was maintained in contrast-enhanced abdominopelvic CT scans that incorporated iterative reconstruction technique, despite reductions in mean CTDI{sub vol} and SSDE by nearly half as compared to the hospital's traditional weight-based protocols. (orig.)

  1. General Information | Bekibele | Nigerian Journal of Ophthalmology

    African Journals Online (AJOL)

    Nigerian Journal of Ophthalmology. Journal Home · ABOUT THIS JOURNAL · Advanced Search · Current Issue · Archives · Journal Home > Vol 22, No 1 (2014) >. Log in or Register to get access to full text downloads.

  2. Caring for academic ophthalmology in Croatia.

    Science.gov (United States)

    Mandić, Zdravko; Vatavuk, Zoran

    2004-06-01

    Like any other area of academic medicine in Croatia, academic ophthalmology has always been limited by or has depended on the factors outside the profession itself: during the communist regime, it was mostly political and ideological correctness of academic ophthalmologists, and today during the social and economic transition, it is the lack of finances, planning, and sophisticated technology. The four university eye clinics, which are the pillars of academic ophthalmology in Croatia, provide health care to most difficult cases, educate students, residents, and specialists, and do research. On the other hand, they lack equipment, room, and financial recognition. This ever growing imbalance between requirements imposed on academic ophthalmology today and its possibilities make it less and less attractive, especially in comparison with private practice. The possible solution lies in increasing the independence of ophthalmology from pharmaceutical industry and politics, especially in research and financial aspects.

  3. Multimodal imaging of vascular network and blood microcirculation by optical diagnostic techniques

    International Nuclear Information System (INIS)

    Kuznetsov, Yu L; Kalchenko, V V; Meglinski, I V

    2011-01-01

    We present a multimodal optical diagnostic approach for simultaneous non-invasive in vivo imaging of blood and lymphatic microvessels, utilising a combined use of fluorescence intravital microscopy and a method of dynamic light scattering. This approach makes it possible to renounce the use of fluorescent markers for visualisation of blood vessels and, therefore, significantly (tenfold) reduce the toxicity of the technique and minimise side effects caused by the use of contrast fluorescent markers. We demonstrate that along with the ability to obtain images of lymph and blood microvessels with a high spatial resolution, current multimodal approach allows one to observe in real time permeability of blood vessels. This technique appears to be promising in physiology studies of blood vessels, and especially in the study of peripheral cardiovascular system in vivo. (optical technologies in biophysics and medicine)

  4. Application of RNB for high sensitive wear diagnostics in medicine technique and industry

    International Nuclear Information System (INIS)

    Fehsenfeld, P.; Eifrig, C.; Kubat, R.

    2002-01-01

    The RTM--Radionuclide Technique in Mechanical engineering--is now extended to the solution of world wide problems in medicine technique (prosthetics), and in development of modern materials (synthetic materials, ceramics, hard coatings, etc.) and their industrial application. RNB--Radioactive Nuclear Beams of 7 Be or 22 Na--may enable the required extreme thin radioactive surface labeling (several micrometers) of synthetic materials for wear measurements without producing radiation damages of influence to the wear properties of the material. The function principle and special properties of the RTM on-line wear diagnostics and its components, the measurement methods, the radioactive surface labeling, and the measurement instruments are explained. The quality features of a 7 Be and 22 Na-beam for RTM application are specified

  5. The clinical neuro-ophthalmology of vision

    International Nuclear Information System (INIS)

    Kashii, Satoshi

    2008-01-01

    To diagnose a patient with a failing visual system, it is necessary to localize the site of the lesion in the system, and identify the etiology that has produced it. Physicians do not see diseases but just their manifestations. Clinical neuro-ophthalmology provides the basic principles on how to progress from manifestations to the diseases they indicate. The Frank B. Walsh Neuro-Ophthalmology Society (the Walsh Society) that originated in 1969 in the United States has been the center of clinical neuro-ophthalmology case studies throughout the world. In Japan, the Ronald M. Burde Clinical Neuro-Ophthalmology Study Group (the RMB Society) was organized in 2001 to establish and promote a clinicopathologic conference in the style of the Walsh Society. On this occasion, Prof. Burde was invited to the Annual Japanese Ophthalmological Society meeting. Based on some illustrative cases presented at the annual meetings of the RMB society, this review was carried out to present the current knowledge of clinical neuro-ophthalmology. (author)

  6. Development of a 2D temperature measurement technique for combustion diagnostics using 2-line atomic fluorescence

    Energy Technology Data Exchange (ETDEWEB)

    Engstroem, Johan

    2001-01-01

    The present thesis is concerned with the development and application of a novel planar laser-induced fluorescence (PLIF) technique for temperature measurements in a variety of combusting flows. Accurate measurement of temperature is an essential task in combustion diagnostics, since temperature is one of the most fundamental quantities for the characterization of combustion processes. The technique is based on two-line atomic fluorescence (TLAF) from small quantities of atomic indium (In) seeded into the fuel. It has been developed from small-scale experiments in laboratory flames to the point where practical combustion systems can be studied. The technique is conceptually simple and reveals temperature information in the post-flame regions. The viability of the technique has been tested in three extreme measurement situations: in spark ignition engine combustion, in ultra-lean combustion situations such as lean burning aero-engine concepts and, finally, in fuel-rich combustion. TLAF was successfully applied in an optical Sl engine using isooctane as fuel. The wide temperature sensitivity, 700 - 3000 K, of the technique using indium atoms allowed measurements over the entire combustion cycle in the engine to be performed. In applications in lean combustion a potential problem caused by the strong oxidation processes of indium atoms was encountered. This limits measurement times due to deposits of absorbing indium oxide on measurement windows. The seeding requirement is a disadvantage of the technique and can be a limitation in some applications. The results from experiments performed in sooting flames are very promising for thermometry measurements in such environments. Absorption by hydrocarbons and other native species was found to be negligible. Since low laser energies and low seeding concentrations could be used, the technique did not, unlike most other incoherent optical thermometry techniques, suffer interferences from LII of soot particles or LIF from PAH

  7. Mining for diagnostic information in body surface potential maps: A comparison of feature selection techniques

    Directory of Open Access Journals (Sweden)

    McCullagh Paul J

    2005-09-01

    Full Text Available Abstract Background In body surface potential mapping, increased spatial sampling is used to allow more accurate detection of a cardiac abnormality. Although diagnostically superior to more conventional electrocardiographic techniques, the perceived complexity of the Body Surface Potential Map (BSPM acquisition process has prohibited its acceptance in clinical practice. For this reason there is an interest in striking a compromise between the minimum number of electrocardiographic recording sites required to sample the maximum electrocardiographic information. Methods In the current study, several techniques widely used in the domains of data mining and knowledge discovery have been employed to mine for diagnostic information in 192 lead BSPMs. In particular, the Single Variable Classifier (SVC based filter and Sequential Forward Selection (SFS based wrapper approaches to feature selection have been implemented and evaluated. Using a set of recordings from 116 subjects, the diagnostic ability of subsets of 3, 6, 9, 12, 24 and 32 electrocardiographic recording sites have been evaluated based on their ability to correctly asses the presence or absence of Myocardial Infarction (MI. Results It was observed that the wrapper approach, using sequential forward selection and a 5 nearest neighbour classifier, was capable of choosing a set of 24 recording sites that could correctly classify 82.8% of BSPMs. Although the filter method performed slightly less favourably, the performance was comparable with a classification accuracy of 79.3%. In addition, experiments were conducted to show how (a features chosen using the wrapper approach were specific to the classifier used in the selection model, and (b lead subsets chosen were not necessarily unique. Conclusion It was concluded that both the filter and wrapper approaches adopted were suitable for guiding the choice of recording sites useful for determining the presence of MI. It should be noted however

  8. A study on the fault diagnostic techniques for reactor internal structures using neutron noise analysis

    International Nuclear Information System (INIS)

    Kim, Tae Ryong; Jeong, Seong Ho; Park, Jin Ho; Park, Jin Suk

    1994-08-01

    The unfavorable phenomena, such as flow induced vibration and aging process in reactor internals, cause degradation of structural integrity and may result in loosing some mechanical binding components which might impact other equipments and components or cause flow blockage. Since these malfunctions and potential failures change reactor noise signal, it is necessary to analyze reactor noise signal for early fault diagnosis in the point of few of safety and plant economics. The objectives of this study are to establish fault diagnostic and TS(thermal shield), and to develop a data acquisition and signal processing software system. In the first year of this study, an analysis technique for the reactor internal vibration using the reactor noise was proposed. With the technique proposed and the reactor noise signals (ex-core neutron and acceleration), the dynamic characteristics of Ulchin-1 reactor internals were obtained, and compared with those of Tricastin-1 which is the prototype of Ulchin-1. In the second year, a PC-based expert system for reactor internals fault diagnosis is developed, which included data acquisition, signal processing, feature extraction function, and represented diagnostic knowledge by the IF-THEN rule. To know the effect of the faults, the reactor internals of Ulchin-1 is modeled using FEM and simulated with an artificial defect given in the hold-down spring. Trend in the dynamic characteristics of reactor internals is also observed during one fuel cycle to know the effect of boron concentration. 100 figs, 7 tabs, 18 refs. (Author)

  9. The Role of Flow Diagnostic Techniques in Fan and Open Rotor Noise Modeling

    Science.gov (United States)

    Envia, Edmane

    2016-01-01

    A principal source of turbomachinery noise is the interaction of the rotating and stationary blade rows with the perturbations in the airstream through the engine. As such, a lot of research has been devoted to the study of the turbomachinery noise generation mechanisms. This is particularly true of fan and open rotors, both of which are the major contributors to the overall noise output of modern aircraft engines. Much of the research in fan and open rotor noise has been focused on developing theoretical models for predicting their noise characteristics. These models, which run the gamut from the semi-empirical to fully computational ones, are, in one form or another, informed by the description of the unsteady flow-field in which the propulsors (i.e., the fan and open rotors) operate. Not surprisingly, the fidelity of the theoretical models is dependent, to a large extent, on capturing the nuances of the unsteady flowfield that have a direct role in the noise generation process. As such, flow diagnostic techniques have proven to be indispensible in identifying the shortcoming of theoretical models and in helping to improve them. This presentation will provide a few examples of the role of flow diagnostic techniques in assessing the fidelity and robustness of the fan and open rotor noise prediction models.

  10. [Application of molecular diagnostic techniques in precision medicine of personalized treatment for colorectal cancer].

    Science.gov (United States)

    Fu, Ji; Lin, Guole

    2016-01-01

    Precision medicine is to customize the treatment options for individual patient based on the personal genome information. Colorectal cancer (CRC) is one of the most common cancer worldwide. Molecular heterogeneity of CRC, which includes the MSI phenotype, hypermutation phenotype, and their relationship with clinical preferences, is believed to be one of the main factors responsible for the considerable variability in treatment response. The development of powerful next-generation sequencing (NGS) technologies allows us to further understand the biological behavior of colorectal cancer, and to analyze the prognosis and chemotherapeutic drug reactions by molecular diagnostic techniques, which can guide the clinical treatment. This paper will introduce the new findings in this field. Meanwhile we integrate the new progress of key pathways including EGFR, RAS, PI3K/AKT and VEGF, and the experience in selective patients through associated molecular diagnostic screening who gain better efficacy after target therapy. The technique for detecting circulating tumor DNA (ctDNA) is introduced here as well, which can identify patients with high risk for recurrence, and demonstrate the risk of chemotherapy resistance. Mechanism of tumor drug resistance may be revealed by dynamic observation of gene alteration during treatment.

  11. Orange fiber laser for ophthalmology

    Science.gov (United States)

    Adachi, M.; Kojima, K.; Hayashi, K.

    2007-02-01

    For the light source of photocoagulators for ophthalmology, orange laser is more suitable than green laser because of low scattering loss by the crystalline lens, and low absorption by xanthophylls in the retina. We developed two orange fiber lasers (580 nm and 590 nm) to investigate the effect depending on the difference in the range of orange. The 580nm laser is composed of a 1160 nm fiber laser and a Periodically Polled Lithium Niobate (PPLN) crystal for second harmonic generation. The 1160 nm fiber laser beam is focused into the MgO-doped PPLN crystal whose length is 30 mm with 3-pass configuration. Continuous-wave 1.3 W output power of 580 nm was obtained with 5.8 W input power of 1160nm for the first time. The conversion efficiency was 22%. The band width of the second harmonic was 0.006 nm (FWHM). The 590 nm laser is almost the same as 580 nm laser source. In this case we used a Raman shift fiber to generate 1180 nm, and the output power of 590 nm was 1.4 W. We developed an evaluation model of photocoagulator system using these two laser sources. A 700 mW coagulation output power was obtained with this orange fiber laser photocoagulator system. This is enough power for the eye surgery. We have the prospect of the maintenance-free, long-life system that is completely air-cooled. We are planning to evaluate this photocoagulator system in order to investigate the difference between the two wavelengths at the field test.

  12. Evaluation of Temporal Diagnostic Techniques for Two-Bunch Facet Beam

    Energy Technology Data Exchange (ETDEWEB)

    Litos, M.D.; Bionta, M.R.; Dolgashev, V.A.; England, R.J.; Fritz, D.; Gilevich, S.; Hering, Ph.; Hogan, M.J.; /SLAC

    2011-08-19

    Three temporal diagnostic techniques are considered for use in the FACET facility at SLAC, which will incorporate a unique two-bunch beam for plasma wakefield acceleration experiments. The results of these experiments will depend strongly on the the inter-bunch spacing as well as the longitudinal profiles of the two bunches. A reliable, singleshot, high resolution measurement of the beam's temporal profile is necessary to fully quantify the physical mechanisms underlying the beam driven plasma wakefield acceleration. In this study we show that a transverse deflecting cavity is the diagnostic which best meets our criteria. Based on our laboratory testing, numerical calculations, and simulations of the three single-shot temporal diagnostic devices, the X-band TCAV system is the best candidate for resolving FACET's two-bunch beam, with an estimated resolution of 7 {micro}m. Both the S-band TCAV system and the EO system could resolve the peak-to-peak separation of the two bunches in the FACET beam with estimated resolutions of 25 {micro}m and 30 {micro}m, respectively, but would be unable to resolve the temporal profiles of the individual bunches themselves. Because the TCAV signal is more easily interpreted and because the reliability of the EO system is less well known, however, the S-band TCAV system would be the next preferred option after the X-band TCAV system. The Fesca-200 streak camera, though simple, compact, and reliable, is unable to achieve a resolution that would be of use to FACET.

  13. Upgrades of Diagnostic Techniques and Technologies for JET next D-T Campaigns

    Energy Technology Data Exchange (ETDEWEB)

    Murari, Andrea [Consorzio RFX - CNR, ENEA, INFN, Universita di Padova, Acciaierie Venete SpA,Corso Stati Uniti 4, 35127 Padova (Italy)

    2015-07-01

    . With regard to the fusion products, JET now can deploy a consistent set of techniques to measure the neutron yield and neutron spectra and to diagnose the fast particles. A full calibration of the neutron diagnostics with a 14 MeV source is being considered, after the recent very successful calibration for the 2.45 MeV neutrons. Vertical and horizontal lines of sight are foreseen for neutron and gamma spectrometry, in order to better determine the thermal neutron yield and to separate the trapped and passing components of the alphas. Various gamma ray spectrometers are being developed to cover all the various operational scenarios, from trace tritium to 50-50 D-T operation. The redistribution of the alphas will be measured with the gamma ray cameras, recently upgraded with full digital electronics; new detectors are being considered to bring the time resolution of the system in the ten of ms range. The lost alphas will also be diagnosed with improved spatial and temporal resolution, using Faraday cups and a scintillator probe. From a technological perspective, the D-T campaign will provide a unique opportunity to test ITER relevant technologies. From radiation hard detectors, for example Hall probes, to neutron absorbers and to shielding concepts, the potential of various solutions in a realistic 14 MeV radiation field will be assessed. The effects of neutrons and gamma on ancillary technologies and systems, such as fibre optics and electronics circuits, are also expected to be sufficiently high to derive useful information about the competitive advantage of various alternatives.

  14. Investigating the perception of Romanian adults on ophthalmology services from an experiential marketing perspective.

    Science.gov (United States)

    Gheorghe, Consuela-Mădălina; Gheorghe, Iuliana-Raluca; Purcărea, Victor Lorin

    2017-01-01

    Nowadays, we live in a world in which we are daily bombed by hundreds of advertisements. Specialists have to discover other channels or embed attractive elements in the advertisements' messages to cut through the clutter and catch the consumers' attention. The evolution of the concept of service has changed from the commercial status to determining a lifestyle. Buying a service has led to a change in the consumer behavior. Consumers want to buy services that dazzle their senses, touch their hearts, and stimulate their minds, not as before, excellent or satisfying. Ophthalmology is the medical specialty that is the most oriented toward outpatient care, as hospitalization is required only in a small percentage of cases. The objective of this case study was to investigate the perception of Romanian adult consumers on ophthalmology services from an experiential marketing perspective, by using the Focus Group method. Ophthalmology requires a wide range of skills due to the diversity of consumers who demand specialized consultations. Experiential marketing is a valuable strategy that ophthalmologic organizations may use to target specific consumers. The purpose of this case study was to identify the perceptions of Romanian adults on experiential marketing campaigns and determine the degree to which these campaigns influenced their decisions of buying an ophthalmologic service. Using a snowball sampling technique we have sent a filter questionnaire to 40 people on the internet. The filter questionnaire consisted of questions about wearing eyeglasses, the period of wearing them, the last ophthalmologic consultation, the type of ophthalmologic clinic they were going to, age and education. The respondents revealed there is almost no visibility on promoting services even if there is an upsurge of organizations offering this type of health service in the Romanian ophthalmology sector.

  15. Investigating the perception of Romanian adults on ophthalmology services from an experiential marketing perspective

    Science.gov (United States)

    Gheorghe, Consuela-Mădălina; Gheorghe, Iuliana-Raluca; Purcărea, Victor Lorin

    2017-01-01

    Nowadays, we live in a world in which we are daily bombed by hundreds of advertisements. Specialists have to discover other channels or embed attractive elements in the advertisements’ messages to cut through the clutter and catch the consumers’ attention. The evolution of the concept of service has changed from the commercial status to determining a lifestyle. Buying a service has led to a change in the consumer behavior. Consumers want to buy services that dazzle their senses, touch their hearts, and stimulate their minds, not as before, excellent or satisfying. Ophthalmology is the medical specialty that is the most oriented toward outpatient care, as hospitalization is required only in a small percentage of cases. The objective of this case study was to investigate the perception of Romanian adult consumers on ophthalmology services from an experiential marketing perspective, by using the Focus Group method. Ophthalmology requires a wide range of skills due to the diversity of consumers who demand specialized consultations. Experiential marketing is a valuable strategy that ophthalmologic organizations may use to target specific consumers. The purpose of this case study was to identify the perceptions of Romanian adults on experiential marketing campaigns and determine the degree to which these campaigns influenced their decisions of buying an ophthalmologic service. Using a snowball sampling technique we have sent a filter questionnaire to 40 people on the internet. The filter questionnaire consisted of questions about wearing eyeglasses, the period of wearing them, the last ophthalmologic consultation, the type of ophthalmologic clinic they were going to, age and education. The respondents revealed there is almost no visibility on promoting services even if there is an upsurge of organizations offering this type of health service in the Romanian ophthalmology sector. PMID:29450395

  16. A novel non-invasive diagnostic sampling technique for cutaneous leishmaniasis.

    Directory of Open Access Journals (Sweden)

    Yasaman Taslimi

    2017-07-01

    Full Text Available Accurate diagnosis of cutaneous leishmaniasis (CL is important for chemotherapy and epidemiological studies. Common approaches for Leishmania detection involve the invasive collection of specimens for direct identification of amastigotes by microscopy and the culturing of promastigotes from infected tissues. Although these techniques are highly specific, they require highly skilled health workers and have the inherent risks of all invasive procedures, such as pain and risk of bacterial and fungal super-infection. Therefore, it is essential to reduce discomfort, potential infection and scarring caused by invasive diagnostic approaches especially for children. In this report, we present a novel non-invasive method, that is painless, rapid and user-friendly, using sequential tape strips for sampling and isolation of DNA from the surface of active and healed skin lesions of CL patients. A total of 119 patients suspected of suffering from cutaneous leishmaniasis with different clinical manifestations were recruited and samples were collected both from their lesions and from uninfected areas. In addition, 15 fungal-infected lesions and 54 areas of healthy skin were examined. The duration of sampling is short (less than one minute and species identification by PCR is highly specific and sensitive. The sequential tape stripping sampling method is a sensitive, non-invasive and cost-effective alternative to traditional diagnostic assays and it is suitable for field studies as well as for use in health care centers.

  17. Diagnostic evaluation of rolling behavior in ball bearings by ultrasonic technique

    International Nuclear Information System (INIS)

    Wakabayashi, T

    2012-01-01

    Failures of machines having rotating parts are mostly caused by damage to bearings and there exist increasing demands for detecting damaged bearings at an early stage. However, conventional diagnostic methods, such as measuring temperature and observing vibration, have found difficulties in performing the early detection, so that more advanced diagnosis is necessary. This study therefore applies an ultrasonic technique as an advanced diagnostic method to bearing life tests. Ultrasonic wave pulses (UWP) emitted from a piezoelectric UWP generator can partially reflect from the interfaces of contact zones within the housing and the bearing with regard to the different acoustic impedance between a solid-to-solid contact and a contact dominated by some fluid layers. Hence, the intensity of the resultant UWP echoes can be determined by the real contact area formed at the interfaces. The experimental results of UWP echoes under the different operating conditions have demonstrated that the time intervals between peaks of UWP echoes varied in accordance with the movement of rolling balls and the lubricating phenomena in bearings. This behavior has further suggested the possibility of the early detection of abnormalities in ball bearings by using the variation in UWP echoes.

  18. Evaluation of diagnostic technique for degradation of low-voltage electric cables with silicone rubber insulator

    International Nuclear Information System (INIS)

    Mikami, Masao

    2005-01-01

    As a part of countermeasures against ageing problems of nuclear power plants, it is requested to establish non-destructive diagnostic technique for their degradation of low voltage electric cables and assessment standard of their life. Having aimed at investigating the degradation of low-voltage electric cable with silicone rubber insulator, change of its surface hardness at elevated temperature were measured by indenter modules. Moreover, we also measured the elongation at break, which is regarded as general degradation index of electric cables, and the surface hardness with a micro hardness meter. Consequently, it is seen that the indenter modulus measurement is (1) capable to obtain general feature of the thermal degradation of silicone rubber insulator, (2) applicable to diagnose the degree of degradation of the electric cable by converting the result to elongation at break, (3) well correlated with the hardness measurement of the electric cable with the micro hardness meter. (author)

  19. Uncertainty Management for Diagnostics and Prognostics of Batteries using Bayesian Techniques

    Science.gov (United States)

    Saha, Bhaskar; Goebel, kai

    2007-01-01

    Uncertainty management has always been the key hurdle faced by diagnostics and prognostics algorithms. A Bayesian treatment of this problem provides an elegant and theoretically sound approach to the modern Condition- Based Maintenance (CBM)/Prognostic Health Management (PHM) paradigm. The application of the Bayesian techniques to regression and classification in the form of Relevance Vector Machine (RVM), and to state estimation as in Particle Filters (PF), provides a powerful tool to integrate the diagnosis and prognosis of battery health. The RVM, which is a Bayesian treatment of the Support Vector Machine (SVM), is used for model identification, while the PF framework uses the learnt model, statistical estimates of noise and anticipated operational conditions to provide estimates of remaining useful life (RUL) in the form of a probability density function (PDF). This type of prognostics generates a significant value addition to the management of any operation involving electrical systems.

  20. IERIAS: inference engine for reactor accident diagnostic system using knowledge engineering technique

    International Nuclear Information System (INIS)

    Yokobayashi, Masao; Yoshida, Kazuo; Kohsaka, Atsuo; Yamamoto, Minoru.

    1984-11-01

    This report describes an inference engine IERIAS which has been devoloped for a diagnostic system to identify the cause and type of an abnormal transient of a reactor plant. This system using knowledge engineering technique consists of a knowledge base and an inference engine. The inference engine IERIAS is designed so as to treat time-varying data of a plant. The major features of IERIAS are ; (1) histroy of transients can be treated, (2) knowledge base can be divided into some knowledge units, (3) program language UTILISP is used which is suitable for symbolic data manipulation. Inference was made using IERIAS with a knowledge base which was created from simulated results of various transients by a PWR plant simulator. The results showed a good applicability of IERIAS for reactor diagnosis. (author)

  1. New Diagnostic, Launch and Model Control Techniques in the NASA Ames HFFAF Ballistic Range

    Science.gov (United States)

    Bogdanoff, David W.

    2012-01-01

    This report presents new diagnostic, launch and model control techniques used in the NASA Ames HFFAF ballistic range. High speed movies were used to view the sabot separation process and the passage of the model through the model splap paper. Cavities in the rear of the sabot, to catch the muzzle blast of the gun, were used to control sabot finger separation angles and distances. Inserts were installed in the powder chamber to greatly reduce the ullage volume (empty space) in the chamber. This resulted in much more complete and repeatable combustion of the powder and hence, in much more repeatable muzzle velocities. Sheets of paper or cardstock, impacting one half of the model, were used to control the amplitudes of the model pitch oscillations.

  2. Probabilistic techniques using Monte Carlo sampling for multi- component system diagnostics

    International Nuclear Information System (INIS)

    Aumeier, S.E.; Lee, J.C.; Akcasu, A.Z.

    1995-01-01

    We outline the structure of a new approach at multi-component system fault diagnostics which utilizes detailed system simulation models, uncertain system observation data, statistical knowledge of system parameters, expert opinion, and component reliability data in an effort to identify incipient component performance degradations of arbitrary number and magnitude. The technique involves the use of multiple adaptive Kalman filters for fault estimation, the results of which are screened using standard hypothesis testing procedures to define a set of component events that could have transpired. Latin Hypercube sample each of these feasible component events in terms of uncertain component reliability data and filter estimates. The capabilities of the procedure are demonstrated through the analysis of a simulated small magnitude binary component fault in a boiling water reactor balance of plant. The results show that the procedure has the potential to be a very effective tool for incipient component fault diagnosis

  3. [Scientific role of German ophthalmology in the European telecommunication project OPHTEL].

    Science.gov (United States)

    Mertz, M; Mann, G; Zahlmann, G; Obermaier, M

    1997-07-01

    In Denmark, France, Germany, Great Britain and Italy, the OPHTEL project combines clinical centers of ophthalmology and internal medicine, an institute for medical informatics and health services research, a publishing company and different industrial partners in the EDP market. With the aid of visual telecommunication and rapid data transfer, methods and conditions will be developed and proved so that any physician can very easily obtain sufficient information for treating his patient. Thus, the regional differences in the quality of structured health service (e.g., urban/ rural) will be overcome throughout Europe. SCIENTIFIC TASKS: A multilingual diagnostic and therapeutic thesaurus has to be worked out in order to create standards for communication and quality control. Based on literature, images and image analysis in a knowledge-based data bank, a monitoring system (containing watch-dog functions) and the basic aspects of an ophthalmological patient/disease register will be investigated. (In parallel, a technical development of synchronous and asynchronous telecommunication between eye physicians is taking place in close cooperation with the regional Bavarian project Teleopathalmology in Bavaria on-line). State of the art 6 months after starting the project:the knowledge-based image data bank has been founded and also an ophthalmological 8 language thesaurus and definition standard. All data transfer lines are installed. The project is taking place amid diverging sections of medicine: ophthalmology and internal medicine, health politics and data protection, individual treatment and common interest (health care), product management and office organization. Thus, the scientific quality of the transferred ophthalmological content must undergo sophisticated controls. FUTURE STEPS: Intense cooperation with the big German associations for ophthalmology (DOG, BVA) and the European ophthalmological societies concerning EDP, classification and quality control.

  4. Reducing beam shaper alignment complexity: diagnostic techniques for alignment and tuning

    Science.gov (United States)

    Lizotte, Todd E.

    2011-10-01

    Safe and efficient optical alignment is a critical requirement for industrial laser systems used in a high volume manufacturing environment. Of specific interest is the development of techniques to align beam shaping optics within a beam line; having the ability to instantly verify by a qualitative means that each element is in its proper position as the beam shaper module is being aligned. There is a need to reduce these types of alignment techniques down to a level where even a newbie to optical alignment will be able to complete the task. Couple this alignment need with the fact that most laser system manufacturers ship their products worldwide and the introduction of a new set of variables including cultural and language barriers, makes this a top priority for manufacturers. Tools and methodologies for alignment of complex optical systems need to be able to cross these barriers to ensure the highest degree of up time and reduce the cost of maintenance on the production floor. Customers worldwide, who purchase production laser equipment, understand that the majority of costs to a manufacturing facility is spent on system maintenance and is typically the largest single controllable expenditure in a production plant. This desire to reduce costs is driving the trend these days towards predictive and proactive, not reactive maintenance of laser based optical beam delivery systems [10]. With proper diagnostic tools, laser system developers can develop proactive approaches to reduce system down time, safe guard operational performance and reduce premature or catastrophic optics failures. Obviously analytical data will provide quantifiable performance standards which are more precise than qualitative standards, but each have a role in determining overall optical system performance [10]. This paper will discuss the use of film and fluorescent mirror devices as diagnostic tools for beam shaper module alignment off line or in-situ. The paper will also provide an overview

  5. A pilot trial of tele-ophthalmology for diagnosis of chronic blurred vision.

    Science.gov (United States)

    Tan, Johnson Choon Hwai; Poh, Eugenie Wei Ting; Srinivasan, Sanjay; Lim, Tock Han

    2013-02-01

    We evaluated the accuracy of tele-ophthalmology in diagnosing the major causes of chronic blurring of vision. Thirty consecutive patients attending a primary eye-care facility in Singapore (the Ang Mo Kio Polyclinic, AMKP) with the symptom of chronic blurred vision were recruited. An ophthalmic technician was trained to perform Snellen acuity; auto-refraction; intraocular pressure measurement; red-colour perimetry; video recordings of extraocular movement, cover tests and pupillary reactions; and anterior segment and fundus photography. Digital information was transmitted to a tertiary hospital in Singapore (the Tan Tock Seng Hospital) via a tele-ophthalmology system for teleconsultation with an ophthalmologist. The diagnoses were compared with face-to-face consultation by another ophthalmologist at the AMKP. A user experience questionnaire was administered at the end of the consultation. Using face-to-face consultation as the gold standard, tele-ophthalmology achieved 100% sensitivity and specificity in diagnosing media opacity (n = 29), maculopathy (n = 23) and keratopathy (n = 30) of any type; and 100% sensitivity and 92% specificity in diagnosing optic neuropathy of any type (n = 24). The majority of the patients (97%) were satisfied with the tele-ophthalmology workflow and consultation. The tele-ophthalmology system was able to detect causes of chronic blurred vision accurately. It has the potential to deliver high-accuracy diagnostic eye support to remote areas if suitably trained ophthalmic technicians are available.

  6. Sportsmen’s Groin—Diagnostic Approach and Treatment With the Minimal Repair Technique

    Science.gov (United States)

    Muschaweck, Ulrike; Berger, Luise Masami

    2010-01-01

    Context: Sportsmen’s groin, also called sports hernia and Gilmore groin, is one of the most frequent sports injuries in athletes and may place an athletic career at risk. It presents with acute or chronic groin pain exacerbated with physical activity. So far, there is little consensus regarding pathogenesis, diagnostic criteria, or treatment. There have been various attempts to explain the cause of the groin pain. The assumption is that a circumscribed weakness in the posterior wall of the inguinal canal, which leads to a localized bulge, induces a compression of the genital branch of the genitofemoral nerve, considered responsible for the symptoms. Methods: The authors developed an innovative open suture repair—the Minimal Repair technique—to fit the needs of professional athletes. With this technique, the circumscribed weakness of the posterior wall of the inguinal canal is repaired by an elastic suture; the compression on the nerve is abolished, and the cause of the pain is removed. In contrast with that of common open suture repairs, the defect of the posterior wall is not enlarged, the suture is nearly tension free, and the patient can return to full training and athletic activity within a shorter time. The outcome of patients undergoing operations with the Minimal Repair technique was compared with that of commonly used surgical procedures. Results: The following advantages of the Minimal Repair technique were found: no insertion of prosthetic mesh, no general anesthesia required, less traumatization, and lower risk of severe complications with equal or even faster convalescence. In 2009, a prospective cohort of 129 patients resumed training in 7 days and experienced complete pain relief in an average of 14 days. Professional athletes (67%) returned to full activity in 14 days (median). Conclusion: The Minimal Repair technique is an effective and safe way to treat sportsmen’s groin. PMID:23015941

  7. Development and applications of laser spectroscopic techniques related to combustion diagnostics

    International Nuclear Information System (INIS)

    Alden, Marcus

    2006-01-01

    Thanks to features as non-intrusiveness combined with high spatial and temporal resolution, various laser diagnostic techniques have during the last decades become of utmost importance for characterization of combustion related phenomena. In the following presentation some further development of the techniques will be highlighted aiming at a) surface temperatures using Thermographic Phosphors, TP, b) species specific, spatially and temporally resolved detection of species absorbing in the IR spectral region using polarization spectroscopy and Laser-induced fluorescence, and finally c) high speed visualization using a special designed laser system in combination with a framing camera. In terms of surface thermometry, Thermographic Phosphors have been used for many years for temperature measurements on solid surfaces. We have during the last years further developed and applied this technique for temperature measurements on burning surfaces and on materials going through phase shifts, e.g. pyrolysis and droplets. The basic principle behind this technique is to apply micron size particles to the surface of interest. By exciting the TP with a short pulse UV laser (ns), the phosphorescence will exhibit a behaviour where the spectral emission as well as the temporal decay are dependent on the temperature. It is thus possible to measure the temperature both in one and two dimensions. The presentation will include basic description of the technique as well as various applications, e.g in fire science, IC engines and gasturbines. Several of the species of interest for combustion/flow diagnostics exhibit a molecular structure which inhibits the use of conventional laser-induced fluorescence for spatially and spectrally resolved measurements. We have during the last years investigated the use of excitation and detection in the infrared region of the spectrum. Here, it is possible to detect both carbonmono/dioxide, water as well as species specific hydrocarbons. The techniques

  8. Effects of Different Compression Techniques on Diagnostic Accuracies of Breast Masses on Digitized Mammograms

    International Nuclear Information System (INIS)

    Zhigang Liang; Xiangying Du; Jiabin Liu; Yanhui Yang; Dongdong Rong; Xinyu Y ao; Kuncheng Li

    2008-01-01

    Background: The JPEG 2000 compression technique has recently been introduced into the medical imaging field. It is critical to understand the effects of this technique on the detection of breast masses on digitized images by human observers. Purpose: To evaluate whether lossless and lossy techniques affect the diagnostic results of malignant and benign breast masses on digitized mammograms. Material and Methods: A total of 90 screen-film mammograms including craniocaudal and lateral views obtained from 45 patients were selected by two non-observing radiologists. Of these, 22 cases were benign lesions and 23 cases were malignant. The mammographic films were digitized by a laser film digitizer, and compressed to three levels (lossless and lossy 20:1 and 40:1) using the JPEG 2000 wavelet-based image compression algorithm. Four radiologists with 10-12 years' experience in mammography interpreted the original and compressed images. The time interval was 3 weeks for each reading session. A five-point malignancy scale was used, with a score of 1 corresponding to definitely not a malignant mass, a score of 2 referring to not a malignant mass, a score of 3 meaning possibly a malignant mass, a score of 4 being probably a malignant mass, and a score of 5 interpreted as definitely a malignant mass. The radiologists' performance was evaluated using receiver operating characteristic analysis. Results: The average Az values for all radiologists decreased from 0.8933 for the original uncompressed images to 0.8299 for the images compressed at 40:1. This difference was not statistically significant. The detection accuracy of the original images was better than that of the compressed images, and the Az values decreased with increasing compression ratio. Conclusion: Digitized mammograms compressed at 40:1 could be used to substitute original images in the diagnosis of breast cancer

  9. The role of choline (Cho) in the diagnostics and differentiation of brain tumours with HMRS technique

    International Nuclear Information System (INIS)

    Sobiecka, B.; Urbanik, A.

    2009-01-01

    Background: The aim of the research was a comprehensive analysis of Cho concentration and Cho/Cr, NAA/Cho, NAA/Cho+Cr ratios for the purposes of the diagnostics and differentiation of brain tumours (the type of the pathological lesion in patients with brain tumours) with the use of HMRS technique. Material/Methods: The HMRS examinations were performed with the use of the MRI Signa Excite 1.5 T system, in PRESS technique (TR = 1500 ms, TE = 35 ms) and involved 100 patients with brain tumours (age range: 18 to 81 yrs, mean age 50.61). Spectra were taken from three different locations: tumour centre, the tumour edge and contralateral unchanged cerebral tissue. All patients underwent surgery followed by histopathological analysis, on the basis of which two groups were separated (benign tumours, malignant tumours - 50 cases each). Additionally, 30 healthy volunteers in the age of 20 to 79 years (mean age 40.8) were examined. Results: The comparison of the examined patients with the control group revealed significantly higher Cho concentrations in patients with brain tumours. The analysis of Cho concentration was also performed with consideration of the age factor (under and over 60 years of age). Significantly lower mean Cho concentrations were discovered in a group of patients under 60 years of age. The analysis of Cho concentrations and Cho/Cr ratios reveled statistical significance for two factors: voxel location factor and the type of the pathological lesion. The average of Cho concentration and Cho/Cr ratios were higher in the group of patients with malignant tumours. The highest Cho concentrations and Cho/Cr ratios were observed in the tumour centre. The relative NAA/Cho and NAA/Cho+Cr ratios were statistically significant when taking into consideration the voxel location factor only. The results received from contralateral normal cerebral tissue (the internal model) were compared with control group (the external model). Mean values of Cho concentration were

  10. Epidemiology of intestinal parasitosis in Italy between 2005 and 2008: diagnostic techniques and methodologies

    Directory of Open Access Journals (Sweden)

    Daniele Crotti

    2013-04-01

    Full Text Available Aim of the study was to keep a real and actual photo relating to 2005-2008 regarding to diagnostic techniques and methodologies for intestinal parasites; so it would be possible to know specific epidemiology and suggest more rational and efficacious guide-lines. All members of AMCLI were involved in the proposal of a retrospective study regarding bowel parasites, helminths and protozoa.To engaged laboratories we asked how O&P was performed, if a specifical research for E. vermicularis and S. stercoralis was performed, if for the identification of D. fragilis, Entamoeba histolytica/dispar and Cryptosporidum spp were performed recommended specific permanent stains. 23 laboratories gave assent; but for an inferior number was possible to use the data for analysis and evaluation. Relating O&P only some laboratories performed permanent stains: Giemsa for D. fragilis, antigen and/or Trichrome stain for E. histolytica/dispar, antigen and/or acid fast stain for Cryptosporidium spp.Not all laboratories research specifically S. stercoralis. So the epidemiology is differentiated and related more to adequate or not adequate techniques than cohorts of examined populations. The overall positivity for parasites ranged from 0% to18.7%,for protozoa (pathogens or not were from 0% to 14.7%; for nematodes from 0% to 3.7%; for cestodes from 0% to 1.0%; for trematodes from 0% to 1.0%.Among helminths, E. vermicularis, followed by S. stercoralis, also in O&P, is the most frequent.The specific research of S. stercoralis gave a positivity from 0% to 33.3%; the cellophane tape test was positive for E. vermicularis from 0% fo 21.9% of cases.Among pathogen protozoa, D. fragilis, when permanent stain were applied, prevailed from 0% to 16.6%; G. duodenalis from 0.8% to 4.3%; E. histolytica/dispar, using a permanent stain or research of antigen, was identified from 0% to 20.6%. Coccidia were very rare, with Cryptosporidium spp observed from 0% to 5.2%. These are our conclusions

  11. General ophthalmology | Bekibele | Nigerian Journal of ...

    African Journals Online (AJOL)

    Transactions of the Ophthalmological Society of Nigeria: Proceedings of the annual OSN Conference, Jos, Nigeria, August 25–28, 2015. Full Text: EMAIL FREE FULL TEXT EMAIL FREE FULL TEXT · DOWNLOAD FULL TEXT DOWNLOAD FULL TEXT · AJOL African Journals Online. HOW TO USE AJOL... for Researchers ...

  12. General ophthalmology | Bekibele | Nigerian Journal of ...

    African Journals Online (AJOL)

    Proceedings from the Ophthalmological Society of Nigeria Conference, 2014. Full Text: EMAIL FREE FULL TEXT EMAIL FREE FULL TEXT · DOWNLOAD FULL TEXT DOWNLOAD FULL TEXT · AJOL African Journals Online. HOW TO USE AJOL... for Researchers · for Librarians · for Authors · FAQ's · More about AJOL ...

  13. Cryotherapy in ophthalmology. Kryotherapie in der Augenheilkunde

    Energy Technology Data Exchange (ETDEWEB)

    Anders, M. (Medizinische Akademie Dresden (Germany))

    1993-01-01

    Ophthalmology is the only medical field in which all of the six known therapeutic applications of low temperature are used. The most important indications are discussed with reference to the corresponding device technology developed at the Department of Cryomedicine of the Dresden Academy of Medicine. (orig.)

  14. Acquisition and retrieval of ophthalmology academic information

    Directory of Open Access Journals (Sweden)

    Lei Li

    2014-06-01

    Full Text Available This article discusses how to search and access ophthalmology information based on specialized websites and resources by introducing the database, search engines, electronic journals, electronic books and so on. Hope to help ophthalmic practitioners to carry out scientific research and clinical practice.

  15. Trends in impact factors of ophthalmology journals.

    Science.gov (United States)

    Vainer, Igor; Mimouni, Francis; Blumenthal, Eytan Z; Mimouni, Michael

    2016-09-01

    To test whether there is an association between the growth in the number of ophthalmic journals in the past years and their mean and maximum impact factor (IF) as a common sign of scientific proliferation. Using data from the 2013 Journal Citation Report database a study of the major clinical medical fields was conducted to assess the correlation between the number of journals and maximum IF in a given field in the year 2013. In the field of ophthalmology, we examined the correlation between year, number of journals, mean IF and maximum IF in the field of ophthalmology throughout the years 2000-2013. In the major medical fields, a positive correlation was found between the number of journals and the maximum IF (quadratic R2 = 0.71, Pjournals and mean IF (R2 = 0.84, Pjournals and maximum IF (R2 = 0.71, Pjournals in the field of ophthalmology. In the future, the formation of additional ophthalmology journals is likely to further increase the IFs of existing journals.

  16. Competency based ophthalmology training curriculum for ...

    African Journals Online (AJOL)

    Background: The establishment of a credible, defensible and acceptable “formal competency based ophthalmology training curriculum for undergraduate medical and dental students” is fundamental to program recognition, monitoring and evaluation. The University of Zimbabwe College of Health Sciences (UZ-CHS) has ...

  17. Mini-FLOTAC, an innovative direct diagnostic technique for intestinal parasitic infections: experience from the field.

    Science.gov (United States)

    Barda, Beatrice Divina; Rinaldi, Laura; Ianniello, Davide; Zepherine, Henry; Salvo, Fulvio; Sadutshang, Tsetan; Cringoli, Giuseppe; Clementi, Massimo; Albonico, Marco

    2013-01-01

    Soil-transmitted helminths and intestinal protozoa infection are widespread in developing countries, yet an accurate diagnosis is rarely performed. The aim of this study was to evaluate the recently developed mini-FLOTAC method and to compare with currently more widely used techniques for the diagnosis of intestinal parasitic infections in different settings. The study was carried out in Dharamsala, Himachal Pradesh, India, and in Bukumbi, Tanzania. A total of 180 pupils from two primary schools had their stool analyzed (n = 80 in Dharamsala and n = 100 in Bukumbi) for intestinal parasitic infections with three diagnostic methods: direct fecal smear, formol-ether concentration method (FECM) and mini-FLOTAC. Overall, 72% of the pupils were positive for any intestinal parasitic infection, 24% carried dual infections and 11% three infections or more. The most frequently encountered intestinal parasites were Entamoeba coli, Entamoeba histolytica/dispar, Giardia intestinalis, hookworm, (and Schistosoma mansoni, in Tanzania). Statistically significant differences were found in the detection of parasitic infections among the three methods: mini-FLOTAC was the most sensitive method for helminth infections (90% mini-FLOTAC, 60% FECM, and 30% direct fecal smear), whereas FECM was most sensitive for intestinal protozoa infections (88% FECM, 70% direct fecal smear, and 68% mini-FLOTAC). We present the first experiences with the mini-FLOTAC for the diagnosis of intestinal helminths and protozoa. Our results suggest that it is a valid, sensitive and potentially low-cost alternative technique that could be used in resource-limited settings--particularly for helminth diagnosis.

  18. Kinetic and Diagnostic Studies of Molecular Plasmas Using Laser Absorption Techniques

    International Nuclear Information System (INIS)

    Welzel, S; Rousseau, A; Davies, P B; Roepcke, J

    2007-01-01

    Within the last decade mid infrared absorption spectroscopy between 3 and 20 μm, known as Infrared Laser Absorption Spectroscopy (IRLAS) and based on tuneable semiconductor lasers, namely lead salt diode lasers, often called tuneable diode lasers (TDL), and quantum cascade lasers (QCL) has progressed considerably as a powerful diagnostic technique for in situ studies of the fundamental physics and chemistry of molecular plasmas. The increasing interest in processing plasmas containing hydrocarbons, fluorocarbons, organo-silicon and boron compounds has lead to further applications of IRLAS because most of these compounds and their decomposition products are infrared active. IRLAS provides a means of determining the absolute concentrations of the ground states of stable and transient molecular species, which is of particular importance for the investigation of reaction kinetics. Information about gas temperature and population densities can also be derived from IRLAS measurements. A variety of free radicals and molecular ions have been detected, especially using TDLs. Since plasmas with molecular feed gases are used in many applications such as thin film deposition, semiconductor processing, surface activation and cleaning, and materials and waste treatment, this has stimulated the adaptation of infrared spectroscopic techniques to industrial requirements. The recent development of QCLs offers an attractive new option for the monitoring and control of industrial plasma processes as well as for highly time-resolved studies on the kinetics of plasma processes. The aim of the present article is threefold: (i) to review recent achievements in our understanding of molecular phenomena in plasmas (ii) to report on selected studies of the spectroscopic properties and kinetic behaviour of radicals, and (iii) to describe the current status of advanced instrumentation for TDLAS in the mid infrared

  19. Diagnostic value of the fluoroscopic triggering 3D LAVA technique for primary liver cancer.

    Science.gov (United States)

    Shen, Xiao-Yong; Chai, Chun-Hua; Xiao, Wen-Bo; Wang, Qi-Dong

    2010-04-01

    Primary liver cancer (PLC) is one of the common malignant tumors. Liver acquisition with acceleration volume acquisition (LAVA), which allows simultaneous dynamic enhancement of the hepatic parenchyma and vasculature imaging, is of great help in the diagnosis of PLC. This study aimed to evaluate application of the fluoroscopic triggering 3D LAVA technique in the imaging of PLC and liver vasculature. The clinical data and imaging findings of 38 adults with PLC (22 men and 16 women; average age 52 years), pathologically confirmed by surgical resection or biopsy, were collected and analyzed. All magnetic resonance images were obtained with a 1.5-T system (General Electrics Medical Systems) with an eight-element body array coil and application of the fluoroscopic triggering 3D LAVA technique. Overall image quality was assessed on a 5-point scale by two experienced radiologists. All the nodules and blood vessel were recorded and compared. The diagnostic accuracy and feasibility of LAVA were evaluated. Thirty-eight patients gave high quality images of 72 nodules in the liver for diagnosis. The accuracy of LAVA was 97.2% (70/72), and the coincidence rate between the extent of tumor judged by dynamic enhancement and pathological examination was 87.5% (63/72). Displayed by the maximum intensity projection reconstruction, nearly all cases gave satisfactory images of branches III and IV of the hepatic artery. Furthermore, small early-stage enhancing hepatic lesions and the parallel portal vein were also well displayed. Sequence of LAVA provides good multi-phase dynamic enhancement scanning of hepatic lesions. Combined with conventional scanning technology, LAVA effectively and safely displays focal hepatic lesions and the relationship between tumor and normal tissues, especially blood vessels.

  20. Development of an Accident Diagnostic Scheme Using Artificial Intelligence Techniques (I)

    Energy Technology Data Exchange (ETDEWEB)

    Na, M. G.; Lee, S. H.; Kim, D. S.; No, Y. G.; Lee, S. W. [Chosun University, Gwangju (Korea, Republic of); Ahn, K. I. [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2010-06-15

    As a means to effectively manage the severe nuclear accidents, it is important to identify and diagnose the accident initiating events during an initial short time interval after the accidents by observing the major controlling parameters. Main objective of this study is to develop the diagnostic approach for the accurate prediction of accident initiating events using artificial intelligence techniques. For this, first, a variety of artificial intelligence techniques such as Finn, Gmbh, and Sm were examined through this study. Among them, Sc and Gmbh model were assessed as a useful approach to predict the break location and the break size of Local. In order to verify the proposed algorithm, the 111 accident simulation data (based on Map) were applied to train the Sc and Gmbh models, and the test data was used to independently verify whether or not the SVC and GMDH models work well. The analysis of the maximum errors and RMS errors, and the performance of the GMDH according to the existence of measurement errors and SIS actuation showed that the proposed SVC and GMDH models can accurately classify the break locations and accurately predict the break size. As the time-integrated signals were used for inputs into the GMDH model within a period of 60 second after a reactor scram, the actuation of the safety systems such as safety injection system (SIS), auxiliary feed water system, and containment spray system, were not considered in this study. It is because the initial 60 second time-integrated signals were used and the safety systems usually start to actuate after a more than 60 second time delay after the reactor scram

  1. Development of an Accident Diagnostic Scheme Using Artificial Intelligence Techniques (I)

    International Nuclear Information System (INIS)

    Na, M. G.; Lee, S. H.; Kim, D. S.; No, Y. G.; Lee, S. W.; Ahn, K. I.

    2010-06-01

    As a means to effectively manage the severe nuclear accidents, it is important to identify and diagnose the accident initiating events during an initial short time interval after the accidents by observing the major controlling parameters. Main objective of this study is to develop the diagnostic approach for the accurate prediction of accident initiating events using artificial intelligence techniques. For this, first, a variety of artificial intelligence techniques such as Finn, Gmbh, and Sm were examined through this study. Among them, Sc and Gmbh model were assessed as a useful approach to predict the break location and the break size of Local. In order to verify the proposed algorithm, the 111 accident simulation data (based on Map) were applied to train the Sc and Gmbh models, and the test data was used to independently verify whether or not the SVC and GMDH models work well. The analysis of the maximum errors and RMS errors, and the performance of the GMDH according to the existence of measurement errors and SIS actuation showed that the proposed SVC and GMDH models can accurately classify the break locations and accurately predict the break size. As the time-integrated signals were used for inputs into the GMDH model within a period of 60 second after a reactor scram, the actuation of the safety systems such as safety injection system (SIS), auxiliary feed water system, and containment spray system, were not considered in this study. It is because the initial 60 second time-integrated signals were used and the safety systems usually start to actuate after a more than 60 second time delay after the reactor scram

  2. Comparative value of diagnostic imaging techniques in a cat with exophthalmos

    International Nuclear Information System (INIS)

    Ramsey, D.T.; Gerding, P.A. Jr.; Losonsky, J.M.; Kuriashkin, I.V.; Clarkson, R.D.

    1994-01-01

    A mass that appeared to originate from the frontal bone and extended into retrobulbar tissues of the light orbit was imaged in a cat using ultrasound, skull radiographs, computed tomography, and magnetic resonance imaging. The cat was presented with ventrolateral strabismus, exophthalmos, and elevated nictitans membrane of the tight eye. The mass was not delineated entirely after orbital echography and survey radiography of the skull was performed. Cytologic examination of fine-needle aspirate of the mass was suggestive of a neoplastic disease. Results of computed tomography indicated lysis of the calvarium but did not delineate borders of the mass in the calvarium. Magnetic resonance imaging was then used to confirm borders of the neoplasm. Magnetic resonance imaging was the only imaging technique that delineated the entire border of the neoplasm, including in the calvarium, when compared to postmortem evaluation. Results of orbital echography, skull radiographs, or computed tomography, when used as the only diagnostic imaging modality, must be interpreted with caution when evaluating borders of retrobulbar neoplasia prior to surgical planning

  3. Fungal disease detection in plants: Traditional assays, novel diagnostic techniques and biosensors.

    Science.gov (United States)

    Ray, Monalisa; Ray, Asit; Dash, Swagatika; Mishra, Abtar; Achary, K Gopinath; Nayak, Sanghamitra; Singh, Shikha

    2017-01-15

    Fungal diseases in commercially important plants results in a significant reduction in both quality and yield, often leading to the loss of an entire plant. In order to minimize the losses, it is essential to detect and identify the pathogens at an early stage. Early detection and accurate identification of pathogens can control the spread of infection. The present article provides a comprehensive overview of conventional methods, current trends and advances in fungal pathogen detection with an emphasis on biosensors. Traditional techniques are the "gold standard" in fungal detection which relies on symptoms, culture-based, morphological observation and biochemical identifications. In recent times, with the advancement of biotechnology, molecular and immunological approaches have revolutionized fungal disease detection. But the drawback lies in the fact that these methods require specific and expensive equipments. Thus, there is an urgent need for rapid, reliable, sensitive, cost effective and easy to use diagnostic methods for fungal pathogen detection. Biosensors would become a promising and attractive alternative, but they still have to be subjected to some modifications, improvements and proper validation for on-field use. Copyright © 2016 Elsevier B.V. All rights reserved.

  4. Nonculture molecular techniques for diagnosis of bacterial disease in animals: a diagnostic laboratory perspective.

    Science.gov (United States)

    Cai, H Y; Caswell, J L; Prescott, J F

    2014-03-01

    The past decade has seen remarkable technical advances in infectious disease diagnosis, and the pace of innovation is likely to continue. Many of these techniques are well suited to pathogen identification directly from pathologic or clinical samples, which is the focus of this review. Polymerase chain reaction (PCR) and gene sequencing are now routinely performed on frozen or fixed tissues for diagnosis of bacterial infections of animals. These assays are most useful for pathogens that are difficult to culture or identify phenotypically, when propagation poses a biosafety hazard, or when suitable fresh tissue is not available. Multiplex PCR assays, DNA microarrays, in situ hybridization, massive parallel DNA sequencing, microbiome profiling, molecular typing of pathogens, identification of antimicrobial resistance genes, and mass spectrometry are additional emerging technologies for the diagnosis of bacterial infections from pathologic and clinical samples in animals. These technical advances come, however, with 2 caveats. First, in the age of molecular diagnosis, quality control has become more important than ever to identify and control for the presence of inhibitors, cross-contamination, inadequate templates from diagnostic specimens, and other causes of erroneous microbial identifications. Second, the attraction of these technologic advances can obscure the reality that medical diagnoses cannot be made on the basis of molecular testing alone but instead through integrated consideration of clinical, pathologic, and laboratory findings. Proper validation of the method is required. It is critical that veterinary diagnosticians understand not only the value but also the limitations of these technical advances for routine diagnosis of infectious disease.

  5. Spiral CT during pharmacoangiography with angiotensin II in patients with pancreatic disease. Technique and diagnostic efficacy

    Energy Technology Data Exchange (ETDEWEB)

    Kuroda, C.; Mihara, N.; Hosomi, N.; Inoue, E.; Fujita, M. [Osaka Medical Center for Cancer and Cardiovascular Diseases (Japan). Dept. of Diagnostic Radiology; Ohigashi, H.; Ishikawa, O. [Osaka Medical Center for Cancer and Cardiovascular Diseases (Japan). Dept. of Surgery; Nakaizumi, A. [Osaka Medical Center for Cancer and Cardiovascular Deseases (Japan). Dept. of Internal Medicine; Ishiguro, S. [Osaka Medical Center for Cancer and Cardiovascular Diseases (Japan). Dept. of Pathology

    1998-03-01

    Purpose: To compare the diagnostic efficacy of pancreatic pharmacoangiographic CT using angiotensin II with conventional angiographic CT. Material and Methods: Eighteen patients with space-occupying pancreatic disease were examined in this study. Pharmacoangiographic CT was performed with a 1-3-{mu}/6-ml solution of angiotensin II injected through a catheter into the celiac artery during spiral CT. Results: In 17 of the 18 (94%) patients, the area of pancreatic parenchymal enhancement was the same or larger at pharmacoangiographic CT than at conventional angiographic CT. The attenuation value of the pancreatic parenchyma was significantly increased at pharmacoangiographic CT (p=0.0010). Although the attenuation value of tumors was also increased on images obtained after the injection of angiotensin II, the tumor-to-pancreas contrast was significantly greater at pharmacoangiographic CT (p=0.0479). The mean differences in attenuation between tumor and pancreas at angiographic CT with and without angiotensin II were respectively 182 HU and 115 HU. Conclusion: Pharmacoangiographic CT with angiotensin II proved superior to conventional angiographic CT in the diagnosis of pancreatic disease. We therefore recommend it as a supplementary technique at the angiographic examination of patients with suspected pancreatic tumor. (orig.).

  6. Modern Diagnostic Techniques for the Assessment of Ocular Blood Flow in Myopia: Current State of Knowledge.

    Science.gov (United States)

    Grudzińska, Ewa; Modrzejewska, Monika

    2018-01-01

    Myopia is the most common refractive error and the subject of interest of various studies assessing ocular blood flow. Increasing refractive error and axial elongation of the eye result in the stretching and thinning of the scleral, choroid, and retinal tissues and the decrease in retinal vessel diameter, disturbing ocular blood flow. Local and systemic factors known to change ocular blood flow include glaucoma, medications and fluctuations in intraocular pressure, and metabolic parameters. Techniques and tools assessing ocular blood flow include, among others, laser Doppler flowmetry (LDF), retinal function imager (RFI), laser speckle contrast imaging (LSCI), magnetic resonance imaging (MRI), optical coherence tomography angiography (OCTA), pulsatile ocular blood flowmeter (POBF), fundus pulsation amplitude (FPA), colour Doppler imaging (CDI), and Doppler optical coherence tomography (DOCT). Many researchers consistently reported lower blood flow parameters in myopic eyes regardless of the used diagnostic method. It is unclear whether this is a primary change that causes secondary thinning of ocular tissues or quite the opposite; that is, the mechanical stretching of the eye wall reduces its thickness and causes a secondary lower demand of tissues for oxygen. This paper presents a review of studies assessing ocular blood flow in myopes.

  7. Neuro-ophthalmology and neuro-otology update.

    Science.gov (United States)

    Gold, Daniel R; Zee, David S

    2015-12-01

    This review summarizes topical papers from the fields of neuro-ophthalmology and neuro-otology published from August 2013 to February 2015. The main findings are: (1) diagnostic criteria for pseudotumor cerebri have been updated, and the Idiopathic Intracranial Hypertension Treatment Trial evaluated the efficacy of acetazolamide in patients with mild vision loss, (2) categorization of vestibular disorders through history and ocular motor examination is particularly important in the acute vestibular syndrome, where timely distinction between a central or peripheral localization is essential, (3) the newly described "sagging eye syndrome" provides a mechanical explanation for an isolated esodeviation that increases at distance in the aging population and (4) eye movement recordings better define how cerebellar dysfunction and/or sixth nerve palsy may play a role in other patients with esodeviations that increase at distance.

  8. Practical X-ray diagnostics orthopedics and trauma surgery. Indication, adjustment technique and radiation protection

    International Nuclear Information System (INIS)

    Flechtenmacher, Johannes; Sabo, Desiderius

    2014-01-01

    The book on X-ray diagnostics in orthopedics and trauma surgery includes the following chapters: 1. Introduction: radiation protection, equipment technology radiological diagnostics of skeleton carcinomas, specific aspects of trauma surgery, special aspects of skeleton radiology for children. 2. X-ray diagnostics of different anatomical regions: ankle joint, knee, hips and pelvis, hand and wrist joint, elbow, shoulder, spinal cord. 3. Appendix: radiation protection according to the X-ray regulations.

  9. Applications of nanoparticles in ophthalmology.

    Science.gov (United States)

    Diebold, Yolanda; Calonge, Margarita

    2010-11-01

    , leaving normal cells untouched. This review summarizes experimental results from our group and others since the beginnings of nanocarrier technology to deliver drugs to different locations in the eye. Also, it explores the future possibilities of nanoparticles not only as drug delivery systems but also as aides for diagnostic purposes. Copyright © 2010 Elsevier Ltd. All rights reserved.

  10. [Citation analysis of originals in Chinese Journal of Ophthalmology].

    Science.gov (United States)

    Cai, Lian

    2002-09-01

    To evaluate the academic level and the popularity of Chinese Journal of Ophthalmology. According to the information of Chinese science and technology papers and citation database (CSTPC), I statistically analyzed the amount and distribution of the originals in Chinese Journal of Ophthalmology cited by the journals included by CSTPC. The originals of Chinese Journal of Ophthalmology were high-qualified and influential, and their authors were all over the country. With the unique style and character, Chinese Journal of Ophthalmology is the main medical core periodical and one of the most important information resources in the field of ophthalmology in China.

  11. A comparison of analogue and digital techniques in upper gastrointestinal examinations: absorbed dose and diagnostic quality of the images

    Energy Technology Data Exchange (ETDEWEB)

    Axelsson, B.; Hansson, I.B. [Department of Hospital Physics, Karolinska Hospital, Stockholm (Sweden); Boden, K.; Witt, H.H. [Department of Diagnostic Radiology, Karolinska Hospital, Stockholm (Sweden); Fransson, S.G. [Department of Thoracic Radiology, University Hospital, Linkoeping (Sweden); Persliden, J. [Department of Radiation Physics, University Hospital, Linkoeping (Sweden)

    2000-08-01

    This study was performed to investigate whether patient exposure and diagnostic quality of the image is significantly influenced by the introduction of digital image acquisition techniques. Evaluation was performed for three different techniques (analogue, analogue fluoro+digital radiography, digital) in examination of the upper gastrointestinal tract. The evaluation was done from data acquired in three different departments. Patient exposure was recorded as KERMA-area product (KAP) and the individual patient readings were normalised to a standard size patient. Image quality was assessed using visual grading with a reference image. The recorded KAP values were significantly higher (22.3 Gycm{sup 2}) for the fully digital technique compared to the others (analogue 6.8 Gycm{sup 2}, analogue+digital 3.6 Gycm{sup 2}). This was due mostly to an increased number of exposures. The diagnostic quality of the image was, however, also regarded to be slightly lower for the technique giving the lowest patient dose with the smallest number of exposures (analogue+digital). The digital examination technique, as used in this study, thus resulted in significantly higher patient dose without any significant gain in diagnostic quality of the image. (orig.)

  12. A comparison of analogue and digital techniques in upper gastrointestinal examinations: absorbed dose and diagnostic quality of the images

    International Nuclear Information System (INIS)

    Axelsson, B.; Hansson, I.B.; Boden, K.; Witt, H.H.; Fransson, S.G.; Persliden, J.

    2000-01-01

    This study was performed to investigate whether patient exposure and diagnostic quality of the image is significantly influenced by the introduction of digital image acquisition techniques. Evaluation was performed for three different techniques (analogue, analogue fluoro+digital radiography, digital) in examination of the upper gastrointestinal tract. The evaluation was done from data acquired in three different departments. Patient exposure was recorded as KERMA-area product (KAP) and the individual patient readings were normalised to a standard size patient. Image quality was assessed using visual grading with a reference image. The recorded KAP values were significantly higher (22.3 Gycm 2 ) for the fully digital technique compared to the others (analogue 6.8 Gycm 2 , analogue+digital 3.6 Gycm 2 ). This was due mostly to an increased number of exposures. The diagnostic quality of the image was, however, also regarded to be slightly lower for the technique giving the lowest patient dose with the smallest number of exposures (analogue+digital). The digital examination technique, as used in this study, thus resulted in significantly higher patient dose without any significant gain in diagnostic quality of the image. (orig.)

  13. Use of sting-response techniques for simulate diagnostics in human esophagus

    International Nuclear Information System (INIS)

    Rodriguez, I.; Gonzalez, Y.; Valdes, L.; Alfonso, J.A.; Estevez, E.

    2003-01-01

    In this work a study of simulation of the gamma graphic studies that are carried out in human esophagus in the Dept. of Nuclear Medicine of the 'Celestino Hernandez Robau Hospital of Santa Clara is presented. For the investigation tubular reactors were used and sting-response techniques with radioactive tracer of Technetium 99 metastable to a concentration of 1 mCi and several flows were applied. The distribution curves of residences times were obtained, those that respond to an equation of the type: Y = A + B exp (- exp((x-C)/D)) - ((x-C/D)+1). They were also carried out, optimizations studies of the doses of the radioactive to give to the patients from 1 mCi (that is the one used in studies) up to 0,5 mCi, and the influences on the obtained distributions of residence time were analyzed. It was confirmed the possibility to lower the doses with clear information of the signal. It was also carried out a simulation of the attenuation of the radiations that takes place in the patients by the interposition of tissues among the analyzed organ, and the detection equipment. It was used paraffin for tissue simulation. It was found the almost independence of the intensity of the radiations with the thickness, for the assayed doses. Lastly it was found a complex mathematical model that responds to the diagnostic curves obtained in these studies, being correlated the coefficients of the pattern with the most important physical parameters of the system, giving it a practical and useful value, all time that the error among the values that this it predicts and the experimental ones do not surpass of 5%. (Author)

  14. Breast Cancer-Related Arm Lymphedema: Incidence Rates, Diagnostic Techniques, Optimal Management and Risk Reduction Strategies

    Energy Technology Data Exchange (ETDEWEB)

    Shah, Chirag [Department of Radiation Oncology, William Beaumont Hospital, Royal Oak, MI (United States); Vicini, Frank A., E-mail: fvicini@beaumont.edu [Department of Radiation Oncology, William Beaumont Hospital, Royal Oak, MI (United States)

    2011-11-15

    As more women survive breast cancer, long-term toxicities affecting their quality of life, such as lymphedema (LE) of the arm, gain importance. Although numerous studies have attempted to determine incidence rates, identify optimal diagnostic tests, enumerate efficacious treatment strategies and outline risk reduction guidelines for breast cancer-related lymphedema (BCRL), few groups have consistently agreed on any of these issues. As a result, standardized recommendations are still lacking. This review will summarize the latest data addressing all of these concerns in order to provide patients and health care providers with optimal, contemporary recommendations. Published incidence rates for BCRL vary substantially with a range of 2-65% based on surgical technique, axillary sampling method, radiation therapy fields treated, and the use of chemotherapy. Newer clinical assessment tools can potentially identify BCRL in patients with subclinical disease with prospective data suggesting that early diagnosis and management with noninvasive therapy can lead to excellent outcomes. Multiple therapies exist with treatments defined by the severity of BCRL present. Currently, the standard of care for BCRL in patients with significant LE is complex decongestive physiotherapy (CDP). Contemporary data also suggest that a multidisciplinary approach to the management of BCRL should begin prior to definitive treatment for breast cancer employing patient-specific surgical, radiation therapy, and chemotherapy paradigms that limit risks. Further, prospective clinical assessments before and after treatment should be employed to diagnose subclinical disease. In those patients who require aggressive locoregional management, prophylactic therapies and the use of CDP can help reduce the long-term sequelae of BCRL.

  15. Breast Cancer-Related Arm Lymphedema: Incidence Rates, Diagnostic Techniques, Optimal Management and Risk Reduction Strategies

    International Nuclear Information System (INIS)

    Shah, Chirag; Vicini, Frank A.

    2011-01-01

    As more women survive breast cancer, long-term toxicities affecting their quality of life, such as lymphedema (LE) of the arm, gain importance. Although numerous studies have attempted to determine incidence rates, identify optimal diagnostic tests, enumerate efficacious treatment strategies and outline risk reduction guidelines for breast cancer–related lymphedema (BCRL), few groups have consistently agreed on any of these issues. As a result, standardized recommendations are still lacking. This review will summarize the latest data addressing all of these concerns in order to provide patients and health care providers with optimal, contemporary recommendations. Published incidence rates for BCRL vary substantially with a range of 2–65% based on surgical technique, axillary sampling method, radiation therapy fields treated, and the use of chemotherapy. Newer clinical assessment tools can potentially identify BCRL in patients with subclinical disease with prospective data suggesting that early diagnosis and management with noninvasive therapy can lead to excellent outcomes. Multiple therapies exist with treatments defined by the severity of BCRL present. Currently, the standard of care for BCRL in patients with significant LE is complex decongestive physiotherapy (CDP). Contemporary data also suggest that a multidisciplinary approach to the management of BCRL should begin prior to definitive treatment for breast cancer employing patient-specific surgical, radiation therapy, and chemotherapy paradigms that limit risks. Further, prospective clinical assessments before and after treatment should be employed to diagnose subclinical disease. In those patients who require aggressive locoregional management, prophylactic therapies and the use of CDP can help reduce the long-term sequelae of BCRL.

  16. [Organizational ethics: a study in ophthalmologic clinics].

    Science.gov (United States)

    Sanches, Maria Aparecida; Scarpi, Marinho Jorge

    2005-01-01

    Research on the field of organizational ethics to investigate to which extent ophthalmologic clinics, inserted in the competitive atmosphere, in the condition of organizations in search of survival, subordinate ethics to competitiveness in the managerial praxis, that is, in the administrative sphere. Kohlberg is taken as theoretical reference, approaching the theme of ethical subordination to competitiveness. The instrument to evaluate moral behaviors of organizations, elaborated by Licht, is applied. The quantitative method is used, adopting analytic instruments, such as Q of Yule and non parametric tests, when dealing with the data of 41 ophthalmologic clinics. The results of the research seem to indicate that administrators of ophthalmologic clinics of greater performance subordinate ethical principles to competitiveness, seeking to assure the survival of the company and, when confronted with the instrument to evaluate their moral behavior, proposed by Kohlberg, have a significantly smaller presence in the postconventional stage than administrators of ophthalmologic clinics with a smaller performance. One may affirm, according to non parametric tests, at the level of significance of 0.05, that the levels of moral development of the two groups differ significantly. The obtained results are according to the literature, especially concerning the "paradox of the ethical subordination and competitiveness". They also suggest that the warrant of the survival of the company tends to reduce the perception of the groups in power regarding the problems that happen in the community, and that a reduction of the ethical values subordinated to competition occurs, and such reduction provokes growing feelings of economical disputes in the social sphere.

  17. [Ophthalmological symptoms of measles and their treatment].

    Science.gov (United States)

    Végh, Mihály; Hári-Kovács, András; Roth, Hans-Walter; Facskó, Andrea

    2017-10-01

    Measles, caused by the Morbilli virus, is a highly (about 95 %) contagious disease affecting primarily children, but without proper immunisation, adults can also be infected. The leading symptoms of the disease are high fever that presents after an incubation period of 9-10 days and the red rash that begins several days after the fever starts. Beyond specific generalized symptoms, measles may have ocular symptoms. The most commonly occurring conjunctivitis, the so-called "red eye symptom", is not characteristic only for measles infection, however, by taking the generalized symptoms it can suggest the diagnosis at the beginning of the disease. Conjunctivitis of varying severity is noticed in the half of the cases without using ophthalmological instrumentation. Using ophthalmological instrumentation, the mild forms of conjunctivitis can be diagnosed, by meticulous ophthalmological examination, further eye diseases can be discovered. The viral conjunctivitis can progress to keratitis and bacterial superinfection can occur. If the infection presents in childhood it can affect the posterior segment. The fight against measles is very effective in Hungary since the vaccination has been introduced, and the lack of vaccination is also the primary cause of the risk to the disease. In the diagnosis, symptomatic treatment of the disease and the curbing of possible mass infections, the practicing physician (general practitioner) has a key role. The correct care of the infected patient in Hungary is provided by a methodological letter, professional information and legal guides. Orv Hetil. 2017; 158(39): 1523-1527.

  18. Crowdsourcing: an overview and applications to ophthalmology.

    Science.gov (United States)

    Wang, Xueyang; Mudie, Lucy; Brady, Christopher J

    2016-05-01

    Crowdsourcing involves the use of the collective intelligence of online communities to produce solutions and outcomes for defined objectives. The use of crowdsourcing is growing in many scientific areas. Crowdsourcing in ophthalmology has been used in basic science and clinical research; however, it also shows promise as a method with wide-ranging applications. This review presents current findings on the use of crowdsourcing in ophthalmology and potential applications in the future. Crowdsourcing has been used to distinguish normal retinal images from images with diabetic retinopathy; the collective intelligence of the crowd was able to correctly classify 81% of 230 images (19 unique) for US$1.10/eye in 20 min. Crowdsourcing has also been used to distinguish normal optic discs from abnormal ones with reasonable sensitivity (83-88%), but low specificity (35-43%). Another study used crowdsourcing for quick and reliable manual segmentation of optical coherence tomography images. Outside of ophthalmology, crowdsourcing has been used for text and image interpretation, language translation, and data analysis. Crowdsourcing has the potential for rapid and economical data processing. Among other applications, it could be used in research settings to provide the 'ground-truth' data, and in the clinical settings to relieve the burden of image processing on experts.

  19. History and development of ophthalmology in Taiwan

    Directory of Open Access Journals (Sweden)

    Yu-Chih Hou

    2016-12-01

    Full Text Available Western medicine was first introduced to Taiwan by medical missionaries in the mid-19th century. Modernization of medicine was systematically transplanted to Taiwan in the Japanese colonial period, and ophthalmology was established third among hospital departments, following internal medicine and surgery. Dr Hidetaka Yamaguchi, an ophthalmologist, was the first head of the Taihoku Hospital, later known as National Taiwan University Hospital (NTUH; Taipei, Taiwan. Ophthalmologists during the colonial period conducted studies on tropical and infectious eye diseases. After World War II, ophthalmologists at NTUH played an important role in medical education, residency training, studies, and teaching. Dr Yan-Fei Yang established the Taiwan Ophthalmological Society in 1960 and instituted its official journal in 1962. Dr Ho-Ming Lin established the Department of Ophthalmology at the Tri-Service General Hospital in the 1950s and the Veterans General Hospital in the 1960s. Taiwan ophthalmologists eradicated trachoma by 1971. Cataract surgery and penetrating keratoplasty were initially performed in the 1960s. Currently, there are about 1600 ophthalmologists in Taiwan conducting an estimated 120,000 cataract surgeries and 600 corneal transplantations annually. Many subspecialty societies have been established recently that serve to educate Taiwanese ophthalmologists and to connect with international ophthalmic societies. Taiwan ophthalmologists continue to contribute to the advancement of ophthalmic knowledge globally.

  20. Funding models for outreach ophthalmology services.

    Science.gov (United States)

    Turner, Angus W; Mulholland, Will; Taylor, Hugh R

    2011-01-01

    This paper aims to describe funding models used and compare the effects of funding models for remuneration on clinical activity and cost-effectiveness in outreach eye services in Australia. Cross-sectional case study based in remote outreach ophthalmology services in Australia. Key stake-holders from eye services in nine outreach regions participated in the study. Semistructured interviews were conducted to perform a qualitative assessment of outreach eye services' funding mechanisms. Records of clinical activity were used to statistically compare funding models. Workforce availability (supply of ophthalmologists), costs of services, clinical activity (surgery and clinic consultation rates) and waiting times. The supply of ophthalmologists (full-time equivalence) to all remote regions was below the national average (up to 19 times lower). Cataract surgery rates were also below national averages (up to 10 times lower). Fee-for-service funding significantly increased clinical activity. There were also trends to shorter waiting times and lower costs per attendance. For outreach ophthalmology services, the funding model used for clinician reimbursement may influence the efficiency and costs of the services. Fee-for-service funding models, safety-net funding options or differential funding/incentives need further exploration to ensure isolated disadvantaged areas prone to poor patient attendance are not neglected. In order for outreach eye health services to be sustainable, remuneration rates need to be comparable to those for urban practice. © 2011 The Authors. Clinical and Experimental Ophthalmology © 2011 Royal Australian and New Zealand College of Ophthalmologists.

  1. The gamma knife in ophthalmology. Part One--Uveal melanoma.

    Science.gov (United States)

    Wygledowska-Promieńska, Dorota; Jurys, Małgorzata; Wilczyński, Tomasz; Drzyzga, Łukasz

    2014-01-01

    The Gamma Knife was designed by Lars Leksell in the early 1950's. It gave rise to a new discipline of medicine--stereotactic radiosurgery. Primarily dedicated to neurosurgery, the Gamma Knife has become an alternative, widely used surgery technique. According to Elekta's statistics, approximately 60,000 people are treated with Leksell Gamma Knife every year and it is the most extensively studied stereotactic radiosurgery system in the world. The Leksell Gamma Knife can also be used in ophthalmology. The gamma ray beam concentration enables effective treatment of uveal melanoma, choroidal hemangioma, orbital tumors or even choroidal neovascularization. The virtue of Leksell Gamma Knife is its extreme precision, non-invasiveness and the possibility of outpatient treatment, which significantly reduces costs and diminishes post-operative complications. Innovative solutions shorten a single session to a minimum, which is very comfortable and safe for both staff and patients. Advantages and possible side effects of gamma knife radiosurgery are well-documented in the professional literature. The objective of this review is to present the recognized applications of Leksell Gamma Knife in ophthalmology.

  2. Finlay y la oftalmología Finlay and ophthalmology

    Directory of Open Access Journals (Sweden)

    Elsa Lisset Arredondo Torres

    2012-04-01

    Full Text Available Se realizó una revisión bibliográfica acerca de la personalidad y la obra del científico camagüeyano Carlos Juan Finlay Barré, para ampliar y profundizar los conocimientos de médicos generales y oftalmólogos. En síntesis, se describe la vida de quien realizó trascendentales contribuciones a la medicina universal. Como sus descubrimientos sobre la fiebre amarilla irradian un conocimiento científico tan elevado, es necesario escudriñar sus aportes a la oftalmología. Se destacan algunos de los aportes más relevantes y de forma precisa se hace referencia a varios estudios realizados por él, así como la descripción de su técnica para la cirugía de catarata.A bibliographical revision on Carlos Juan Finlay Barré’s life and work was carried out to widen and deepen knowledge on general medicine and ophthalmology. In short, the life of man who made significant contributions to universal medicine is herein described. As his discoveries about the yellow fever have provided prominent scientific knowledge, so it is necessary to examine his contributions to ophthalmology. Some of his more relevant contributions and studies are also pointed out, as well as the description of his technique for cataract surgery.

  3. Uncertainty Management for Diagnostics and Prognostics of Batteries using Bayesian Techniques

    Data.gov (United States)

    National Aeronautics and Space Administration — Uncertainty management has always been the key hurdle faced by diagnostics and prognostics algorithms. A Bayesian treatment of this problem provides an elegant and...

  4. Ophthalmology resident surgical competency: a national survey.

    Science.gov (United States)

    Binenbaum, Gil; Volpe, Nicholas J

    2006-07-01

    To describe the prevalence, management, and career outcomes of ophthalmology residents who struggle with surgical competency and to explore related educational issues. Fourteen-question written survey. Fifty-eight program directors at Accreditation Council on Graduate Medical Education-accredited, United States ophthalmology residency programs, representing a total of 2179 resident graduates, between 1991 and 2000. Study participants completed a mailed, anonymous survey whose format combined multiple choice and free comment questions. Number of surgically challenged residents, types of problems identified, types of remediation, final departmental decision at the end of residency, known career outcomes, and residency program use of microsurgical skills laboratories and applicant screening tests. One hundred ninety-nine residents (9% overall; 10% mean per program) were labeled as having trouble mastering surgical skills. All of the programs except 2 had encountered such residents. The most frequently cited problems were poor hand-eye coordination (24%) and poor intraoperative judgment (22%). Most programs were supportive and used educational rather than punitive measures, the most common being extra practice-laboratory time (32%), scheduling cases with the best teaching surgeon (23%), and counseling (21%). Nearly one third (31%) of residents were believed to have overcome their difficulties before graduation. Other residents were encouraged to pursue medical ophthalmology (22%) or to obtain further surgical training through a fellowship (21%) or a supervised practice setting (12%); these residents were granted a departmental statement of satisfactory completion of residency for Board eligibility. Twelve percent were asked to leave residency. Of reported career outcomes, 92% of residents were practicing ophthalmology, 65% as surgical and 27% as medical ophthalmologists. Ninety-eight percent of residency programs had microsurgical practice facilities, 64% had a formal

  5. Advanced Surveillance, Diagnostic and Prognostic Techniques in Monitoring Structures, Systems and Components in Nuclear Power Plants

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2013-09-15

    direction of research, development and demonstration in this area. The technologies discussed in this project are intended to establish the state of the art in surveillance, diagnostics and prognostics (SDP) technologies for equipment and process health monitoring in nuclear facilities. It is also intended to identify technology gaps and research needs of the nuclear industry in the area of SDP. The report draws on the conventional SDP technologies, as well as the latest tools, algorithms and techniques that have emerged over the last few years, especially in enabling technologies including fast data acquisition, data storage, data qualification and data analysis algorithms, such as empirical and physical modelling techniques. These new tools have made it possible to identify problems earlier and with better resolution. The significance of the material presented in this report is that it contributes not only to the current needs of the nuclear industry but also to the design improvements of the next generation of reactors. For example, the nuclear industry is currently striving to operate the plants for up to 80 years or more, as the value of nuclear assets has risen in recent years, resulting partly from environmental concerns with fossil energy production, as well as increased future demand for base load electricity. This long term operation (LTO) or life extension goal of the nuclear industry has stimulated renewed interest in more frequent monitoring of equipment to guard against ageing effects, not to mention the economic benefits that SDP implementation can produce, and contributions to radiation exposure that is as low as reasonably achievable, reduction of human errors, and optimized maintenance. Together with capabilities that enhance situational awareness, the technologies described in this report will enable more holistic management of plant structures, systems and components (SSCs), maintain high capacity factor in LTO and enable higher levels of safe operation

  6. Advanced Surveillance, Diagnostic and Prognostic Techniques in Monitoring Structures, Systems and Components in Nuclear Power Plants

    International Nuclear Information System (INIS)

    2013-01-01

    direction of research, development and demonstration in this area. The technologies discussed in this project are intended to establish the state of the art in surveillance, diagnostics and prognostics (SDP) technologies for equipment and process health monitoring in nuclear facilities. It is also intended to identify technology gaps and research needs of the nuclear industry in the area of SDP. The report draws on the conventional SDP technologies, as well as the latest tools, algorithms and techniques that have emerged over the last few years, especially in enabling technologies including fast data acquisition, data storage, data qualification and data analysis algorithms, such as empirical and physical modelling techniques. These new tools have made it possible to identify problems earlier and with better resolution. The significance of the material presented in this report is that it contributes not only to the current needs of the nuclear industry but also to the design improvements of the next generation of reactors. For example, the nuclear industry is currently striving to operate the plants for up to 80 years or more, as the value of nuclear assets has risen in recent years, resulting partly from environmental concerns with fossil energy production, as well as increased future demand for base load electricity. This long term operation (LTO) or life extension goal of the nuclear industry has stimulated renewed interest in more frequent monitoring of equipment to guard against ageing effects, not to mention the economic benefits that SDP implementation can produce, and contributions to radiation exposure that is as low as reasonably achievable, reduction of human errors, and optimized maintenance. Together with capabilities that enhance situational awareness, the technologies described in this report will enable more holistic management of plant structures, systems and components (SSCs), maintain high capacity factor in LTO and enable higher levels of safe operation

  7. Development of a diagnostic technique based on Cherenkov effect for measurements of fast electrons in fusion devices

    Energy Technology Data Exchange (ETDEWEB)

    Plyusnin, V. V.; Duarte, P.; Fernandes, H.; Silva, C. [Association Euratom/IST, Instituto de Plasmas e Fusao Nuclear, Instituto Superior Tecnico, Universidade Tecnica de Lisboa, Av. Rovisco Pais, 1049-001 Lisboa (Portugal); Jakubowski, L.; Zebrowski, J.; Malinowski, K.; Rabinski, M.; Sadowski, M. J. [National Centre for Nuclear Research (NCBJ), 7 Andrzeja Soltana Str., 05-400 Otwock (Poland)

    2012-08-15

    A diagnostic technique based on the Cherenkov effect is proposed for detection and characterization of fast (super-thermal and runaway) electrons in fusion devices. The detectors of Cherenkov radiation have been specially designed for measurements in the ISTTOK tokamak. Properties of several materials have been studied to determine the most appropriate one to be used as a radiator of Cherenkov emission in the detector. This technique has enabled the detection of energetic electrons (70 keV and higher) and the determination of their spatial and temporal variations in the ISTTOK discharges. Measurement of hard x-ray emission has also been carried out in experiments for validation of the measuring capabilities of the Cherenkov-type detector and a high correlation was found between the data of both diagnostics. A reasonable agreement was found between experimental data and the results of numerical modeling of the runaway electron generation in ISTTOK.

  8. Neuro-ophthalmological manifestations of neurosyphilis in 22 cases

    Directory of Open Access Journals (Sweden)

    Xiao-Juan Fan

    2017-10-01

    Full Text Available AIM: To analyze the characteristics of neurological ophthalmology manifestation of patients with neurosyphilis.METHODS: Retrospective and nonrandomized case analysis were used. Totally 22 cases of 39 eyes were included. They were 17 males and 5 females, aged from 34 to 65 years old. The average age were 49.6 years old. RESULTS: The optic nerve atrophy presented in 11 cases of 22 eyes. One eye of them accompanied by left eye oculomotor nerve palsy; 5 eyes in 3 cases expressed as optic neuritis acute phase; neuroretinitis appeared in 4 cases of 6 eyes; 1 case of 2 eyes expressed as chorioretinitis accompanied by optic disc edema; central retinal artery occlusion were found in 1 case of 1 eye. Argyll-Robertson pupil was as only manifestation in 2 cases of 3 eyes. In all cases, Argyll-Robertson pupil signs can be seen in 19 eyes. Treponema pallidum particle agglutination test(TPPAwere positive in all 22 cases. Syphilis rapid plasma reactin test(RPRwere positive in 19 of 21 cases. All patients underwent lumbar puncture and cerebrospinal fluid were detected for RPR, cerebrospinal fluid protein, white blood cell count. Cerebrospinal fluid RPR were positive in 13 cases. Cerebrospinal fluid protein were greater than 450mg/L in 18 cases. Cerebrospinal fluid white blood cell count were greater than 5/mm3 in 13 cases. CONCLUSION: Neurosyphilis involving neuro-ophthalmology often occurs in middle-aged men and subacute onset. Both eyes can suffered from optic nerve disease simultaneously or sequencely. A few can be expressed as other cranial nerve palsy, which may lead to misdiagnosis. Considering medical history, clinical manifestations, ophthalmic examination, serum and cerebrospinal fluid laboratory tests can improve the diagnostic rate.

  9. Diagnostic tools for nearest neighbors techniques when used with satellite imagery

    Science.gov (United States)

    Ronald E. McRoberts

    2009-01-01

    Nearest neighbors techniques are non-parametric approaches to multivariate prediction that are useful for predicting both continuous and categorical forest attribute variables. Although some assumptions underlying nearest neighbor techniques are common to other prediction techniques such as regression, other assumptions are unique to nearest neighbor techniques....

  10. The Diagnostic Challenge Competition: Probabilistic Techniques for Fault Diagnosis in Electrical Power Systems

    Science.gov (United States)

    Ricks, Brian W.; Mengshoel, Ole J.

    2009-01-01

    Reliable systems health management is an important research area of NASA. A health management system that can accurately and quickly diagnose faults in various on-board systems of a vehicle will play a key role in the success of current and future NASA missions. We introduce in this paper the ProDiagnose algorithm, a diagnostic algorithm that uses a probabilistic approach, accomplished with Bayesian Network models compiled to Arithmetic Circuits, to diagnose these systems. We describe the ProDiagnose algorithm, how it works, and the probabilistic models involved. We show by experimentation on two Electrical Power Systems based on the ADAPT testbed, used in the Diagnostic Challenge Competition (DX 09), that ProDiagnose can produce results with over 96% accuracy and less than 1 second mean diagnostic time.

  11. Development of a neural network technique for KSTAR Thomson scattering diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Seung Hun, E-mail: leesh81@nfri.re.kr; Lee, J. H. [National Fusion Research Institute, 169-148 Gwahak-ro, Yuseong-gu, Daejeon 34133 (Korea, Republic of); Yamada, I. [National Institute Fusion Science, Toki, Gifu 509-5292 (Japan); Park, Jae Sun [Department of Physics, Korea Advanced Institute of Science and Technology, 291 Daehak-ro, Yuseong-gu, Daejeon 34141 (Korea, Republic of)

    2016-11-15

    Neural networks provide powerful approaches of dealing with nonlinear data and have been successfully applied to fusion plasma diagnostics and control systems. Controlling tokamak plasmas in real time is essential to measure the plasma parameters in situ. However, the χ{sup 2} method traditionally used in Thomson scattering diagnostics hampers real-time measurement due to the complexity of the calculations involved. In this study, we applied a neural network approach to Thomson scattering diagnostics in order to calculate the electron temperature, comparing the results to those obtained with the χ{sup 2} method. The best results were obtained for 10{sup 3} training cycles and eight nodes in the hidden layer. Our neural network approach shows good agreement with the χ{sup 2} method and performs the calculation twenty times faster.

  12. Ethical and deontological dominants in ophthalmology

    Directory of Open Access Journals (Sweden)

    O. M. Panko

    2014-02-01

    Full Text Available In the article the ethical and deontological dominants as scientific and practical strategy that prevents the medical errors, and humanization doctor-patient relationship through a formation of culture of communication are presented. Ophthalmology as a branch of practical and scientific medicine requires special relationship between doctor and patient, and because of this it also requires particular ethical and deontological interpretation. Formal signs of ethics laws concerning ophthalmic practice aren’t worth anything in case of unskilled diagnosis and treatment. Possibility of errors on the part of the doctor-ophthalmologist while aiding a patient is of a special importance. In planed and in urgent cases irreparable flaws are not excluded. Consideration should be given, in particular, to the errors in the initial examination, insufficient amount of additional methods of examination, overdiagnosis, errors in determining the treatment strategy (conservative or surgical and others. Identification and analysis of the errors in order to prevent them is the ethical imperative in medical practice and effective way to improve clinical medicine. The author of the article describes the causes of errors, indicating that they are objective and subjective. The first are related to the change of views on the treatment of a certain disease. The complex of therapeutic measures, that was considered the most rational until recently, can be proven as wrong from the perspective of the latest achievements of science. Mistakes made by doctors in their communication with patients as a result of not following the basic deontological principles are also included here. In addition, the classification of medical errors on deontological, diagnostic, therapeutic is made and their essence is analyzed in the article. The violation of the principles of appropriate behavior of the doctor in treating the patient, that is not following the ethics of medical practice by the

  13. Diagnostics of glass fiber reinforced polymers and comparative analysis of their fabrication techniques with the use of acoustic emission

    Science.gov (United States)

    Bashkov, O. V.; Bryansky, A. A.; Panin, S. V.; Zaikov, V. I.

    2016-11-01

    Strength properties of the glass fiber reinforced polymers (GFRP) fabricated by vacuum and vacuum autoclave molding techniques were analyzed. Measurements of porosity of the GFRP parts manufactured by various molding techniques were conducted with the help of optical microscopy. On the basis of experimental data obtained by means of acoustic emission hardware/software setup, the technique for running diagnostics and forecasting the bearing capacity of polymeric composite materials based on the result of three-point bending tests has been developed. The operation principle of the technique is underlined by the evaluation of the power function index change which takes place on the dependence of the total acoustic emission counts versus the loading stress.

  14. Estimating the burden of pneumococcal pneumonia among adults: a systematic review and meta-analysis of diagnostic techniques.

    Directory of Open Access Journals (Sweden)

    Maria A Said

    Full Text Available Pneumococcal pneumonia causes significant morbidity and mortality among adults. Given limitations of diagnostic tests for non-bacteremic pneumococcal pneumonia, most studies report the incidence of bacteremic or invasive pneumococcal disease (IPD, and thus, grossly underestimate the pneumococcal pneumonia burden. We aimed to develop a conceptual and quantitative strategy to estimate the non-bacteremic disease burden among adults with community-acquired pneumonia (CAP using systematic study methods and the availability of a urine antigen assay.We performed a systematic literature review of studies providing information on the relative yield of various diagnostic assays (BinaxNOW® S. pneumoniae urine antigen test (UAT with blood and/or sputum culture in diagnosing pneumococcal pneumonia. We estimated the proportion of pneumococcal pneumonia that is bacteremic, the proportion of CAP attributable to pneumococcus, and the additional contribution of the Binax UAT beyond conventional diagnostic techniques, using random effects meta-analytic methods and bootstrapping. We included 35 studies in the analysis, predominantly from developed countries. The estimated proportion of pneumococcal pneumonia that is bacteremic was 24.8% (95% CI: 21.3%, 28.9%. The estimated proportion of CAP attributable to pneumococcus was 27.3% (95% CI: 23.9%, 31.1%. The Binax UAT diagnosed an additional 11.4% (95% CI: 9.6, 13.6% of CAP beyond conventional techniques. We were limited by the fact that not all patients underwent all diagnostic tests and by the sensitivity and specificity of the diagnostic tests themselves. We address these resulting biases and provide a range of plausible values in order to estimate the burden of pneumococcal pneumonia among adults.Estimating the adult burden of pneumococcal disease from bacteremic pneumococcal pneumonia data alone significantly underestimates the true burden of disease in adults. For every case of bacteremic pneumococcal pneumonia

  15. Intercomparison of techniques for inspection and diagnostics of heavy water reactor pressure tubes. Determination of hydrogen concentration and blister characterization

    International Nuclear Information System (INIS)

    2009-03-01

    Heavy water reactors (HWRs) comprise significant numbers of today's operating nuclear power plants, and more are under construction. Efficient and accurate inspection and diagnostic techniques for various reactor components and systems, especially pressure tubes, are an important factor in ensuring reliable and safe plant operation. To foster international collaboration in the efficient and safe use of nuclear power, the IAEA conducted a Coordinated Research Project (CRP) on Intercomparison of Techniques for HWR Pressure Tube Inspection and Diagnostics. This CRP was carried out within the framework of the IAEA's Technical Working Group on Advanced Technologies for HWRs (the TWG-HWR). The TWG-HWR is a group of experts nominated by their governments and designated by the IAEA to provide advice and to support implementation of IAEA's project on advanced technologies for HWRs. The objective of the CRP was to compare non-destructive inspection and diagnostic techniques, in use and being developed, for structural integrity assessment of HWR pressure tubes. During the first phase of this CRP participants investigated the capability of different techniques to detect and characterize flaws. During the second phase participants collaborated to detect and characterize hydride blisters and to determine the hydrogen concentration in zirconium alloys. The intention was to identify the most effective pressure tube inspection and diagnostic methods and to identify further development needs. The organizations which participated in phase 2 of this CRP are: - Comision Nacional de Energia Atomica (CNEA), Argentina; - Atomic Energy of Canada Ltd. (AECL), Chalk River Laboratories (CRL), Canada; - Bhabha Atomic Research Centre (BARC), India; - Korea Atomic Energy Research Institute (KAERI), Republic of Korea; - National Institute for Research and Development for Technical Physics (NIRDTP), Romania; - Nuclear Non-Destructive Testing Research and Services (NNDT), Romania. IAEA-TECDOC-1499

  16. Amniotic membrane allografts: development and clinical utility in ophthalmology

    Directory of Open Access Journals (Sweden)

    Rizzuti A

    2014-12-01

    Full Text Available Allison Rizzuti,1,2 Adam Goldenberg,1 Douglas R Lazzaro1,2 1SUNY Downstate Medical Center, 2Kings County Hospital Center, Brooklyn, NY, USA Abstract: Amniotic membrane, the innermost layer of the placenta, is a tissue that promotes epithelialization, while decreasing inflammation, neovascularization, and scarring. It is used in the surgical management of a wide variety of ophthalmic conditions where it functions as a graft or patch in ocular surface reconstruction. The development of new preservation techniques, as well as a sutureless amniotic membrane, has allowed for easier, in-office placement, without the disadvantages of an operating room procedure. The purpose of this review is to describe the historical development of amniotic membrane in ophthalmology and to describe its current clinical applications, particularly focusing on recent advances. Keywords: ocular surface, cornea, stem cells, prokera, allograft, patch, transplantation

  17. Principles for new optical techniques in medical diagnostics for mHealth applications

    Science.gov (United States)

    Balsam, Joshua Michael

    Medical diagnostics is a critical element of effective medical treatment. However, many modern and emerging diagnostic technologies are not affordable or compatible with the needs and conditions found in low-income and middle-income countries and regions. Resource-poor areas require low-cost, robust, easy-to-use, and portable diagnostics devices compatible with telemedicine (i.e. mHealth) that can be adapted to meet diverse medical needs. Many suitable devices will need to be based on optical technologies, which are used for many types of biological analyses. This dissertation describes the fabrication and detection principles for several low-cost optical technologies for mHealth applications including: (1) a webcam based multi-wavelength fluorescence plate reader, (2) a lens-free optical detector used for the detection of Botulinum A neurotoxin activity, (3) a low cost micro-array reader that allows the performance of typical fluorescence based assays demonstrated for the detection of the toxin staphylococcal enterotoxin (SEB), and (4) a wide-field flow cytometer for high throughput detection of fluorescently labeled rare cells. This dissertation discusses how these technologies can be harnessed using readily available consumer electronics components such as webcams, cell phones, CCD cameras, LEDs, and laser diodes. There are challenges in developing devices with sufficient sensitivity and specificity, and approaches are presented to overcoming these challenges to create optical detectors that can serve as low cost medical diagnostics in resource-poor settings for mHealth.

  18. Development of in situ cleaning techniques for diagnostic mirrors in ITER

    International Nuclear Information System (INIS)

    Litnovsky, A.; Laengner, M.; Matveeva, M.; Schulz, Ch.; Marot, L.; Voitsenya, V.S.; Philipps, V.; Biel, W.; Samm, U.

    2011-01-01

    Mirrors will be used in all optical and laser-based diagnostic systems of ITER. In the severe environment, the optical characteristics of mirrors will be degraded, hampering the entire performance of the respective diagnostics. A minute impurity deposition of 20 nm of carbon on the mirror is sufficient to decrease the mirror reflectivity by tens of percent outlining the necessity of the mirror cleaning in ITER. The results of R and D on plasma cleaning of molybdenum diagnostic mirrors are reported. The mirrors contaminated with amorphous carbon films in the laboratory conditions and in the tokamaks were cleaned in steady-state hydrogenic plasmas. The maximum cleaning efficiency of 4.2 nm/min was reached for the laboratory and soft tokamak hydrocarbon films, whereas for the hard tokamak films the carbidization of mirrors drastically decreased the cleaning efficiency down to 0.016 nm/min. This implies the necessity of sputtering cleaning of contaminated mirrors as the only reliable tool to remove the deposits by plasma cleaning. An overview of R and D program on mirror cleaning is provided along with plans for further studies and the recommendations for ITER mirror-based diagnostics.

  19. Draft of diagnostic techniques for primary coolant circuit facilities using control computer

    International Nuclear Information System (INIS)

    Suchy, R.; Procka, V.; Murin, V.; Rybarova, D.

    A method is proposed of in-service on-line diagnostics of primary circuit selected parts by means of a control computer. Computer processing will involve the measurements of neutron flux, pressure difference in pumps and in the core, and the vibrations of primary circuit mechanical parts. (H.S.)

  20. Experiences with E-learning in Ophthalmology

    OpenAIRE

    Seema Dutt Bandhu; Swati Raje

    2014-01-01

    Introduction: E-learning is the use of internet for the purpose of education. E-learning in medical education is at a nascent stage in our country. The present study was carried out with the purpose of introducing e-learning to third year medical students in the subject of Ophthalmology and taking feedback on their attitude towards the new methodology of teaching and evaluating. Materials and Methods: E-learning was introduced to the seventh semester students of MBBS in the subject of Ophthal...

  1. THE TECHNIQUE OF DIAGNOSTICS OF THE PRODUCTION CAPACITY OF THE ORGANIZATION

    Directory of Open Access Journals (Sweden)

    E. S. Popova

    2014-01-01

    Full Text Available In the article due to the need for diagnostics of the production capacity of the organization. Formed methodological framework for evaluating the production potential of the organization. Research capacity will also enable the organization to timely respond to current changes. A classification of types of diagnostics of the production capacity of the organization according to the following criteria: timing, goals, content, purpose results. The article discusses the economic and organizational diagnosis of the production capacity of the organization. Economic diagnosis is based on the calculation of indicators of use of resources of the organization. Organizational diagnosis assesses the security of the organization's activities. Diagnosis productive capacity is the basis for improvement of the organization's activities. Defined diagnostics of the production capacity of the organization. Justified the selection stages of the research production potential. The first stage is the preliminary diagnosis. The second stage provides for the rapid diagnosis of production potential. At the third stage it is advisable to perform problem diagnosis. Problem diagnosis consists of economic and organizational diagnosis. Economic diagnosis assesses the state of the elements of the production potential of the organization. Organizational diagnostics analyses provide productive capacity. The fourth stage is represented by the solution of the problems of utilization of production capacity. Each stage is considered, has its content and specific diagnostic methods of production potential. This method allows determining the state of the elements, the efficiency of utilization of production capacity. The estimation of the production potential is based on the application of utility theory. This assessment provides a definition of the criteria and the scale of usefulness. This will allow you to measure the production potential numerically. In the end, it is revealed

  2. Robotic-assisted surgery in ophthalmology.

    Science.gov (United States)

    de Smet, Marc D; Naus, Gerrit J L; Faridpooya, Koorosh; Mura, Marco

    2018-05-01

    Provide an overview of the current landscape of robotics in ophthalmology, including the pros and cons of system designs, the clinical development path, and the likely future direction of the field. Robots designed for eye surgery should meet certain basic requirements. Three designs are currently being developed: smart surgical tools such as the steady hand, comanipulation devices and telemanipulators using either a fixed or virtual remote center of motion. Successful human intraocular surgery is being performed using the Preceyes surgical system. Another telemanipulation robot, the da Vinci Surgical System, has been used to perform a pterygium repair in humans and was successful in ex-vivo corneal surgery despite its nonophthalmic design. Apart from Preceyes' BV research platform, none of the currently eye-specific systems has reached a commercial stage. Systems are likely to evolve from robotic assistance during specific procedural steps to semiautonomous surgery, as smart sensors are introduced to enhance the basic functionalities of robotic systems. Robotics is still in its infancy in ophthalmology but is rapidly reaching a stage wherein it will be introduced into everyday ophthalmic practice. It will most likely be introduced first for demanding vitreo-retinal procedures, followed by anterior segment applications.

  3. The simple analytical method for scattered radiation calculation in contrast X-ray diagnostic techniques

    Energy Technology Data Exchange (ETDEWEB)

    Markovic, S; Pavlovic, R [Inst. of Nuclear Science Vinca, Belgrade (Yugoslavia). Radiation and Environmental Protection Lab.; Boreli, F [Fac. of Electrical Engineering, Belgrade (Yugoslavia)

    1996-12-31

    In realization of radiation protection measures for medical staff present during diagnostic procedures, the necessary condition is knowledge of the space - energy distributions of the scattered radiation from the patient. In this paper, the simple calculation procedure for the scattered radiation field of the actual diagnostic energies is presented. Starting from the single Compton scattering model and using the justified transformations the final equations in elementary form are derived. For numerical calculations the computer code ANGIO was created. The calculated results were confirmed by detailed dosimetric measurements of the scattered field around patient (the water phantom) in SSDL in the Institute of nuclear sciences `Vinca`, Belgrade. These results are good base for assessment of irradiation. The main irradiation source for the physician and the other members of the medical team is the back scattered radiation from patient - albedo. (author). 3 figs., 3 refs.

  4. A novelty detection diagnostic methodology for gearboxes operating under fluctuating operating conditions using probabilistic techniques

    Science.gov (United States)

    Schmidt, S.; Heyns, P. S.; de Villiers, J. P.

    2018-02-01

    In this paper, a fault diagnostic methodology is developed which is able to detect, locate and trend gear faults under fluctuating operating conditions when only vibration data from a single transducer, measured on a healthy gearbox are available. A two-phase feature extraction and modelling process is proposed to infer the operating condition and based on the operating condition, to detect changes in the machine condition. Information from optimised machine and operating condition hidden Markov models are statistically combined to generate a discrepancy signal which is post-processed to infer the condition of the gearbox. The discrepancy signal is processed and combined with statistical methods for automatic fault detection and localisation and to perform fault trending over time. The proposed methodology is validated on experimental data and a tacholess order tracking methodology is used to enhance the cost-effectiveness of the diagnostic methodology.

  5. Application of the SWE-to-PWE antenna diagnostics technique to an offset reflector antenna

    DEFF Research Database (Denmark)

    Cappellin, Cecilia; Frandsen, Aksel; Breinbjerg, Olav

    2008-01-01

    Electrical and mechanical errors in an antenna may seriously affect the antenna's performance. Although their presence is usually detected by anomalies in the antenna's far-field pattern, their identification is normally possible only through an analysis of the antenna's extreme near field....... The reconstruction of the extreme near field on the basis of near- or far-field measurements is thus an essential step in antenna diagnostics....

  6. Diagnostic Accuracy of Imaging Modalities and Injection Techniques for the Diagnosis of Femoroacetabular Impingement/Labral Tear

    DEFF Research Database (Denmark)

    Reiman, Michael P.; Thorborg, Kristian; Goode, Adam P.

    2017-01-01

    Background: Diagnosing femoroacetabular impingement/acetabular labral tear (FAI/ALT) and subsequently making a decision regarding surgery are based primarily on diagnostic imaging and intra-articular hip joint injection techniques of unknown accuracy. Purpose: Summarize and evaluate the diagnostic...... probability of disease was demonstrated. Positive imaging findings increased the probability that a labral tear existed by a minimal to small degree with the use of magnetic resonance imaging/magnetic resonance angiogram (MRI/MRA) and ultrasound (US) and by a moderate degree for CTA. Negative imaging findings...... decreased the probability that a labral tear existed by a minimal degree with the use of MRI and US, a small to moderate degree with MRA, and a moderate degree with CTA. Clinical Relevance: Although findings of the included studies suggested potentially favorable use of these modalities for the diagnosis...

  7. Modeling the consumer’s perception of experiential marketing in the Romanian private ophthalmologic services

    Science.gov (United States)

    Gheorghe, Consuela-Mădălina; Gheorghe, Iuliana-Raluca; Purcărea, Victor Lorin

    2017-01-01

    Introduction. The importance of experience in marketing grew, as the concept itself is very personal and difficult to measure. Experience turns out to be complicated but once placed in a context it gets significant features. As the health care competitive environment increases, marketers are looking for new and effective methods of engaging consumers by using experiential marketing strategies. Moreover, little is known about the consumers’ perceptions related to ophthalmologic services. Aim. The objective of this paper was to measure the consumer’s perception of experiential marketing in the Romanian private ophthalmologic services by using structural equation modeling. Materials and Methods. The Experiential Marketing model consisted of the following components: Sense Experience, Feel Experience, Think Experience, Act Experience and Relate Experience as well as the consequences of applying Experiential Marketing in the form of willingness to purchase a service, generating word-of-mouth communication and building consumer loyalty. The sampling method was non-probabilistic, using the snowball technique and the sample was made up of 190 people who wore eyeglasses for more than 3 years. The instrument for data collection was a self-administered questionnaire, which consisted of 2 parts: the first section contained several demographic questions and the second section encompassed closed end questions related to the perception of private ophthalmologic services from an experiential marketing perspective. All the second section questions were measured on a 5-point Likert scale ranging from 1 with Strongly Disagree to 5 to Strongly Agree. The data analysis was conducted in SPSS and the structural equation modeling was performed in WarpPLS version 6.0. Findings. There were 71.05% respondents, who appreciated the application of experiential marketing in private ophthalmologic services, followed by 18.95%, who were confused. The demographic profile of respondents

  8. Modeling the consumer's perception of experiential marketing in the Romanian private ophthalmologic services.

    Science.gov (United States)

    Gheorghe, Consuela-Mădălina; Gheorghe, Iuliana-Raluca; Purcărea, Victor Lorin

    2017-01-01

    Introduction. The importance of experience in marketing grew, as the concept itself is very personal and difficult to measure. Experience turns out to be complicated but once placed in a context it gets significant features. As the health care competitive environment increases, marketers are looking for new and effective methods of engaging consumers by using experiential marketing strategies. Moreover, little is known about the consumers' perceptions related to ophthalmologic services. Aim. The objective of this paper was to measure the consumer's perception of experiential marketing in the Romanian private ophthalmologic services by using structural equation modeling. Materials and Methods. The Experiential Marketing model consisted of the following components: Sense Experience, Feel Experience, Think Experience, Act Experience and Relate Experience as well as the consequences of applying Experiential Marketing in the form of willingness to purchase a service, generating word-of-mouth communication and building consumer loyalty. The sampling method was non-probabilistic, using the snowball technique and the sample was made up of 190 people who wore eyeglasses for more than 3 years. The instrument for data collection was a self-administered questionnaire, which consisted of 2 parts: the first section contained several demographic questions and the second section encompassed closed end questions related to the perception of private ophthalmologic services from an experiential marketing perspective. All the second section questions were measured on a 5-point Likert scale ranging from 1 with Strongly Disagree to 5 to Strongly Agree. The data analysis was conducted in SPSS and the structural equation modeling was performed in WarpPLS version 6.0. Findings. There were 71.05% respondents, who appreciated the application of experiential marketing in private ophthalmologic services, followed by 18.95%, who were confused. The demographic profile of respondents encompassed

  9. Comparison of advanced optical imaging techniques with current otolaryngology diagnostics for improved middle ear assessment (Conference Presentation)

    Science.gov (United States)

    Nolan, Ryan M.; Shelton, Ryan L.; Monroy, Guillermo L.; Spillman, Darold R.; Novak, Michael A.; Boppart, Stephen A.

    2016-02-01

    Otolaryngologists utilize a variety of diagnostic techniques to assess middle ear health. Tympanometry, audiometry, and otoacoustic emissions examine the mobility of the tympanic membrane (eardrum) and ossicles using ear canal pressure and auditory tone delivery and detection. Laser Doppler vibrometry provides non-contact vibrational measurement, and acoustic reflectometry is used to assess middle ear effusion using sonar. These technologies and techniques have advanced the field beyond the use of the standard otoscope, a simple tissue magnifier, yet the need for direct visualization of middle ear disease for superior detection, assessment, and management remains. In this study, we evaluated the use of portable optical coherence tomography (OCT) and pneumatic low-coherence interferometry (LCI) systems with handheld probe delivery to standard tympanometry, audiometry, otoacoustic emissions, laser Doppler vibrometry, and acoustic reflectometry. Comparison of these advanced optical imaging techniques and current diagnostics was conducted with a case study subject with a history of unilateral eardrum trauma. OCT and pneumatic LCI provide novel dynamic spatiotemporal structural data of the middle ear, such as the thickness of the eardrum and quantitative detection of underlying disease pathology, which could allow for more accurate diagnosis and more appropriate management than currently possible.

  10. Using technique vibration diagnostics for assessing the quality of power transmission line supports repairs

    Directory of Open Access Journals (Sweden)

    Cherpakov Aleksander

    2017-01-01

    Full Text Available The considered method for assessing the quality of the repair work to restore the rack supports of transmission lines is based on the method of vibration diagnostics. Power transmission line supports with a symmetrical destruction of the protective layer of concrete in the ground in violation of the construction section were chosen as an object. Finite element modelling package Ansys was used in assessing the quality of repair work. The example of evaluating the quality of repair using the relative adhesion defective area design criteria in the analysis of natural vibration frequencies is given.

  11. Intercomparison of techniques for inspection and diagnostics of heavy water reactor pressure tubes: Flaw detection and characterization [Phase 1

    International Nuclear Information System (INIS)

    2006-05-01

    Nuclear power plants with heavy water reactors (HWRs) comprise nine percent of today's operating nuclear units, and more are under construction. Efficient and accurate inspection and diagnostic techniques for various reactor components and systems are an important factor in assuring reliable and safe plant operation. To foster international collaboration in the efficient and safe use of nuclear power, the IAEA conducted a Coordinated Research Programme (CRP) on Inter-comparison of Techniques for HWR Pressure Tube Inspection and Diagnostics. This CRP was carried out within the frame of the IAEA Department of Nuclear Energy's Technical Working Group on Advanced Technologies for HWRs (the TWG-HWR). The TWG-HWR is a group of experts nominated by their governments and designated by the IAEA to provide advice and to support implementation of the IAEA's project on advanced technologies for HWRs. The objective of the CRP was to inter-compare non-destructive inspection and diagnostic techniques, in use and being developed, for structural integrity assessment of HWR pressure tubes. During the first phase of this CRP, participants have investigated the capability of different techniques to detect and characterize flaws. During the second phase of this CRP, participants collaborated to detect and characterize hydride blisters and to determine the hydrogen concentration in Zirconium alloys. The intent was to identify the most effective pressure tube inspection and diagnostic methods, and to identify further development needs. The organizations that have participated in this CRP are: - The Comision Nacional de Energia Atomica (CNEA), Argentina; - Atomic Energy of Canada Ltd. (AECL); Chalk River Laboratories (CRL), Canada; - The Research Institute of Nuclear Power Operations (RINPO), China National Nuclear Corporation (CNNC), China; - Bhabha Atomic Research Centre (BARC), India; - The Korea Electric Power Research Institute (KEPRI), Republic of Korea; - The Korea Atomic Energy

  12. Pocket book on setting techniques for medical imaging. X-ray diagnostics, angiography, CT, MRT. 4. rev. and enl. ed.; Taschenatlas Einstelltechnik. Roentgendiagnostik, Angiografie, CT, MRT

    Energy Technology Data Exchange (ETDEWEB)

    Moeller, Torsten B.; Reif, Emil [Caritas-Krankenhaus, Dillingen/Saar (Germany)

    2009-07-01

    The pocketbook on setting techniques for medical imaging is concerned with the problem to prepare appropriate images for diagnostic purposes using modern high-technology instruments like x-ray diagnostics, angiography, computerized tomography and magnetic resonance tomography. The following issues are covered: Head, spinal column, upper extremities, lower extremities, thorax, gastrointestinal tract, intravenous organ examination, angiography, computerized tomography, NMR imaging.

  13. Improvement of diagnostic techniques and electrical circuit in azo dye degradation by high voltage electrical discharge

    International Nuclear Information System (INIS)

    Shen Yongjun; Lei Lecheng; Zhang Xingwang; Zhou Minghua; Zhang Yi

    2008-01-01

    Fast electrical diagnostics and improvement of electrical circuits for methyl orange (MO) degradation by high voltage pulsed electrical discharge were investigated. To eliminate electromagnetic radiation, several effective methods were employed. RG 218 coaxial cable was substituted for the common transmission lines to transmit high voltage pulses, and multi-lines in parallel were earthed to avoid electromagnetic interference and, additionally, to reduce the stray inductance of the electrical circuit and increase the pulse rise rate to reduce the energy losses in the transmission system. The problem of the differences in the bandwidths of voltage and current probes causing an error in the calculation of energy dissipation was avoided by reducing the bandwidths of voltage and current measurements to the same value. The real discharge current was obtained by subtracting the capacitive current from the total current. The energy per pulse obtained in the reactor before and after improvement of the diagnostics and electrical circuit were 15.5 mJ and 26.8 mJ, respectively, and the energy efficiencies of MO degradation were 1.34 x 10 -9 mol/J and 1.95 x 10 -9 mol/J, respectively

  14. An efficient diagnostic technique for distribution systems based on under fault voltages and currents

    Energy Technology Data Exchange (ETDEWEB)

    Campoccia, A.; Di Silvestre, M.L.; Incontrera, I.; Riva Sanseverino, E. [Dipartimento di Ingegneria Elettrica elettronica e delle Telecomunicazioni, Universita degli Studi di Palermo, viale delle Scienze, 90128 Palermo (Italy); Spoto, G. [Centro per la Ricerca Elettronica in Sicilia, Monreale, Via Regione Siciliana 49, 90046 Palermo (Italy)

    2010-10-15

    Service continuity is one of the major aspects in the definition of the quality of the electrical energy, for this reason the research in the field of faults diagnostic for distribution systems is spreading ever more. Moreover the increasing interest around modern distribution systems automation for management purposes gives faults diagnostics more tools to detect outages precisely and in short times. In this paper, the applicability of an efficient fault location and characterization methodology within a centralized monitoring system is discussed. The methodology, appropriate for any kind of fault, is based on the use of the analytical model of the network lines and uses the fundamental components rms values taken from the transient measures of line currents and voltages at the MV/LV substations. The fault location and identification algorithm, proposed by the authors and suitably restated, has been implemented on a microprocessor-based device that can be installed at each MV/LV substation. The speed and precision of the algorithm have been tested against the errors deriving from the fundamental extraction within the prescribed fault clearing times and against the inherent precision of the electronic device used for computation. The tests have been carried out using Matlab Simulink for simulating the faulted system. (author)

  15. Diagnostic and corrective procedures for TL analysis using the pre-dose technique

    International Nuclear Information System (INIS)

    Haskell, E.H.

    1985-01-01

    The high sensitivity of the pre-dose TL technique using fired quartz grains with relatively low doses makes it the only TL technique that is generally suitable for retrospective environmental dosimetry. The use of this technique for dose measurements of less than 0.2 Gy has been the focus of research at the Utah laboratory, while the extension of the useful range of the pre-dose technique to doses in excess of 5 Gy has been the aim of the Durham laboratory. Certain characteristics of the pre-dose phenomenon, if not properly diagnosed, can lead to erroneous dose estimates at both extremes. This paper describes the procedures used at both laboratories to diagnose such problems and recently developed methods for their circumvention. (author)

  16. A Roadmap of Risk Diagnostic Methods: Developing an Integrated View of Risk Identification and Analysis Techniques

    National Research Council Canada - National Science Library

    Williams, Ray; Ambrose, Kate; Bentrem, Laura

    2004-01-01

    ...), which is envisioned to be a comprehensive reference tool for risk identification and analysis (RI AND A) techniques. Program Managers (PMs) responsible for developing or acquiring software-intensive systems typically identify risks in different ways...

  17. Do Anesthetic Techniques Influence the Threshold for Glomerular Capillary Hemorrhage Induced in Rats by Contrast-Enhanced Diagnostic Ultrasound?

    Science.gov (United States)

    Miller, Douglas L; Lu, Xiaofang; Fabiilli, Mario; Dou, Chunyan

    2016-02-01

    Glomerular capillary hemorrhage can be induced by ultrasonic cavitation during contrast-enhanced diagnostic ultrasound (US) exposure, an important nonthermal US bioeffect. Recent studies of pulmonary US exposure have shown that thresholds for another nonthermal bioeffect of US, pulmonary capillary hemorrhage, is strongly influenced by whether xylazine is included in the specific anesthetic technique. The objective of this study was to determine the influence of xylazine on contrast-enhanced diagnostic US-induced glomerular capillary hemorrhage. In this study, anesthesia with ketamine only was compared to ketamine plus xylazine for induction of glomerular capillary hemorrhage in rats by 1.6-MHz intermittent diagnostic US with a microsphere contrast agent (similar to Definity; Lantheus Medical Imaging, Inc, North Billerica, MA). Glomerular capillary hemorrhage was measured as a percentage of glomeruli with hemorrhage found in histologic sections for groups of rats scanned at different peak rarefactional pressure amplitudes. There was a significant difference between the magnitude of the glomerular capillary hemorrhage between the anesthetics at 2.3 MPa, with 45.6% hemorrhage for ketamine only, increasing to 63.2% hemorrhage for ketamine plus xylazine (P Ultrasound in Medicine.

  18. Low-level therapy in ophthalmology

    Science.gov (United States)

    Pankov, O. P.

    1999-07-01

    Extremely slow introduction of low-level laser therapy into the practice of ophthalmologists is restricted by the lack of good methodological recommendation and modern equipment adopted to the needs of ophthalmology. The most perspective is considered to be further improvement of the methods and the elaboration of the medical equipment, working in several wave bands, combined with magnetotherapy and working with the use of various modes of the modulation of the intensity of the luminous flux. It may be asserted that unlike the mode of continuous radiation, in some cases, the effectiveness of the treatment increases when the modulated light with the frequency of one to a few tens HZ is used. Moreover, the methods are being elaborated, when the modulation frequency of laser light and the biorhythms of man physiologic parameters are synchronized. Very perspective seems the computerization of the treatment process with the simultaneous electrophysiological control of the condition of visual functions.

  19. Application of OCT angiography in ophthalmology

    Directory of Open Access Journals (Sweden)

    Ai-Ping Yang

    2017-11-01

    Full Text Available Optical coherence tomography angiography(OCTAis a new technology of angiography in recent years. In addition to the advantages of traditional OCT, it can observe blood flow in different retinal and choroidal segmentation slab. By using the pseudo-color, abnormal vascular structure can be distinguished from normal vascular structure of the retina. Dye injection is not needed with OCTA, which is different from fundus fluorescein angiography(FFAand indocyanine green angiography(ICGA. OCTA provides more and more accurate blood flow information. However, like other biometric technology, OCTA has its limitations and shortcomings. This review will analyze and summarize the operating principle of OCTA, its application in ophthalmology, as well as its advantages and limitations.

  20. Experiences with E-learning in Ophthalmology

    Directory of Open Access Journals (Sweden)

    Seema Dutt Bandhu

    2014-01-01

    Full Text Available Introduction: E-learning is the use of internet for the purpose of education. E-learning in medical education is at a nascent stage in our country. The present study was carried out with the purpose of introducing e-learning to third year medical students in the subject of Ophthalmology and taking feedback on their attitude towards the new methodology of teaching and evaluating. Materials and Methods: E-learning was introduced to the seventh semester students of MBBS in the subject of Ophthalmology. The topics were converted to web friendly format and used for teaching and evaluating. Feedback was taken from the students on completion of the term on their attitudes towards e-learning and their views on the scope of e-learning in medical education. Results: All the students agreed on the usefulness of e-learning in medical education. Eleven students (27.5% found the medium of e-learning to be interesting, 15 (37.5% considered it to be easy and accessible, 10 (25% found it to be fast and easy, 4 (10% considered it to be a medium which can give updated information. Twenty-three (57.5% students considered that e-learning should be a medium of instruction in all the subjects, 15 (37.5% students considered its usefulness in clinical subjects only. Twenty-eight students (70% desired that e-learning should be used to provide important notes, questions, MCQs on all topics. Conclusions: E-learning is well accepted as a medium of instruction by medical students.

  1. Development of reactor accident diagnostic system DISKET using knowledge engineering technique

    International Nuclear Information System (INIS)

    Yokobayashi, Masao; Yoshida, Kazuo; Kohsaka, Atsuo; Yamamoto, Minoru.

    1986-01-01

    An accident diagnostic system DISKET has been developed to identify the cause and the type of an abnormal transient of a nuclear power plant. The system is based on the knowledge engineering (KE) and consists of an inference engine IERIAS and a knowledge base. The main features of DISKET are the following : (1) Time-varying characteristics of transients can be treated. (2) Knowledge base can be divided into several knowledge units to handle a lot of rules effectively. (3) Programming language UTILISP, which is a dialect of LISP, is used to manipulate symbolic data effectively. For the verification of DISKET, performance tests have been conducted for several types of accidents. The knowledge base used in the tests was generated from the data of various types of transients produced by a PWR plant simulator. The results of verification studies showed a good applicability of DISKET to reactor accident diagnosis. (author)

  2. Diagnostic prénatal: quelles sont les techniques actuelles et futures ? (flyer)

    CERN Multimedia

    2002-01-01

    La majorité des bébés qui viennent au monde ne présentent pas d'anomalies particulières. Cependant, il faut savoir qu'environ 1 foetus 170 présente une anomalie chromosomique (défaut de la structure ou du nombre de chromosomes) qui va peser plus ou moins lourdement sur sa vie future et 1 foetus sur 100 présente une maladie génique due à un changement dans un gène. Le diagnostic prénatal a connu et connaît une formidable expansion grâce aux progrès technologiques en génétique et imagerie foetale.

  3. The integration of novel diagnostics techniques for multi-scale monitoring of large civil infrastructures

    Directory of Open Access Journals (Sweden)

    F. Soldovieri

    2008-11-01

    Full Text Available In the recent years, structural monitoring of large infrastructures (buildings, dams, bridges or more generally man-made structures has raised an increased attention due to the growing interest about safety and security issues and risk assessment through early detection. In this framework, aim of the paper is to introduce a new integrated approach which combines two sensing techniques acting on different spatial and temporal scales. The first one is a distributed optic fiber sensor based on the Brillouin scattering phenomenon, which allows a spatially and temporally continuous monitoring of the structure with a "low" spatial resolution (meter. The second technique is based on the use of Ground Penetrating Radar (GPR, which can provide detailed images of the inner status of the structure (with a spatial resolution less then tens centimetres, but does not allow a temporal continuous monitoring. The paper describes the features of these two techniques and provides experimental results concerning preliminary test cases.

  4. Risk estimation in association with diagnostic techniques in the nuclear medicine service of the Camaguey Ciego de Avila Territory

    International Nuclear Information System (INIS)

    Barrerras, C.A.; Brigido, F.O.; Naranjo, L.A.; Lasserra, S.O.; Hernandez Garcia, J.

    1999-01-01

    The nuclear medicine service at the Maria Curie Oncological Hospital, Camaguey, has experience of over three decades in using radiofarmaceutical imaging agents for diagnosis. Although the clinical risk associated with these techniques is negligible, it is necessary to evaluate the effective dose administered to the patient due to the introduction of radioactive substances into the body. The study of the dose administered to the patient provides useful data for evaluating the detriment associated with this medical practice, its subsequently optimization and consequently, for minimizing the stochastic effects on the patient. The aim of our paper is to study the collective effective dose administered by nuclear medicine service to Camaguey and Ciego de Avila population from 1995 to 1998 and the relative contribution to the total annual effective collective dose of the different diagnostic examinations. The studies were conducted on the basis of statistics from nuclear medicine examinations given to a population of 1102353 inhabitants since 1995. The results show that the nuclear medicine techniques of neck examinations with 1168.8 Sv man (1.11 Sv/expl), thyroid explorations with 119.6 Sv man (55.5 mSv/expl) and iodide uptake with 113.7 Sv man (14.0 mSv/expl) are the main techniques implicated in the relative contribution to the total annual effective collective dose of 1419.5 Sv man. The risk estimation in association with diagnostic techniques in the nuclear medicine service studied is globally low (total detriment: 103.6 as a result of 16232 explorations), similar to other published data

  5. Critical evaluation of fine needle aspiration cytology as a diagnostic technique in bone tumors and tumor-like lesions.

    Science.gov (United States)

    Chakrabarti, Sudipta; Datta, Alok Sobhan; Hira, Michael

    2012-01-01

    Though open surgical biopsy is the procedure of choice for the diagnosis of bone tumors, many disadvantages are associated with this approach. The present study was undertaken to evaluate the role of fine needle aspiration cytology (FNAC) as a diagnostic tool in cases of bony tumors and tumor-like lesions which may be conducted in centers where facilities for surgical biopsies are inadequate. The study population consisted of 51 cases presenting with a skeletal mass. After clinical evaluation, radiological correlation was done to assess the nature and extent of each lesion. Fine needle aspiration was performed aseptically and smears were prepared. Patients subsequently underwent open surgical biopsy and tissue samples were obtained for histopathological examination. Standard statistical methods were applied for analysis of data. Adequate material was not obtained even after repeated aspiration in seven cases, six of which were benign. Among the remaining 44 cases, diagnosis of malignancy was correctly provided in 28 (93.3%) out of 30 cases and categorical diagnosis in 20 (66.67%). Interpretation of cytology was more difficult in cases of benign and tumor-like lesions, with a categorical opinion only possible in seven (50%) cases. Statistical analysis showed FNAC with malignant tumors to have high sensitivity (93.3%), specificity (92.9%) and positive predictive value of 96.6%, whereas the negative predictive value was 86.7%. FNAC should be included in the diagnostic workup of a skeletal tumor because of its simplicity and reliability. However, a definitive pathologic diagnosis heavily depends on compatible clinical and radiologic features which can only be accomplished by teamwork. The cytological technique applied in this study could detect many bone tumors and tumor-like conditions and appears particularly suitable as a diagnostic technique for rural regions of India as other developing countries.

  6. Diagnostic technique for measuring fusion reaction rate for inertial confinement fusion experiments at Shen Guang-III prototype laser facility

    International Nuclear Information System (INIS)

    Wang Feng; Peng Xiao-Shi; Liu Shen-Ye; Xu Tao; Kang Dong-Guo

    2013-01-01

    A study is conducted using a two-dimensional simulation program (Lared-s) with the goal of developing a technique to evaluate the effect of Rayleigh-Taylor growth in a neutron fusion reaction region. Two peaks of fusion reaction rate are simulated by using a two-dimensional simulation program (Lared-s) and confirmed by the experimental results. A neutron temporal diagnostic (NTD) system is developed with a high temporal resolution of ∼ 30 ps at the Shen Guang-III (SG-III) prototype laser facility in China, to measure the fusion reaction rate history. With the shape of neutron reaction rate curve and the spherical harmonic function in this paper, the degree of Rayleigh-Taylor growth and the main source of the neutron yield in our experiment can be estimated qualitatively. This technique, including the diagnostic system and the simulation program, may provide important information for obtaining a higher neutron yield in implosion experiments of inertial confinement fusion

  7. A thermal technique for local ultrasound intensity measurement: part 2. Application to exposimetry on a medical diagnostic device

    International Nuclear Information System (INIS)

    Wilkens, V

    2010-01-01

    Acoustic output measurements on medical ultrasound equipment are usually performed using radiation force balances to determine the output power and using hydrophones to determine pressure and intensity parameters. The local temporal-average ultrasound intensity can be measured alternatively by thermal sensors. The technique was described and prototype sensors were characterized in a preceding paper. Here, the application of such a thermal intensity sensor to the output beam characterization of a typical medical diagnostic device is described. Two transducers, a 7.5 MHz linear array and a 3.5 MHz convex array were investigated in different operating modes. For comparison, hydrophone measurements were also performed. If the spatial averaging effect is taken into account, good agreement is found between both measurement methods. The maximum deviations of the spatial-peak temporal-average intensities I SPTA obtained with the thermal sensor from the corresponding hydrophone-based results were below 12%. The simple thermal technique offers advantages for intensity measurements especially in the case of scanning and combined modes of the diagnostic device, where the synchronization between hydrophone measurements and the complex pulse emission pattern can be difficult

  8. The invention of gonioscopy by Alexios Trantas and his contribution to ophthalmology.

    Science.gov (United States)

    Kalantzis, G; Georgalas, I; Tsiamis, C; El-Hindy, N; Poulakou-Rebelakou, E

    2015-01-01

    Gonioscopy is a technique used to examine structures in the anterior chamber angle (the fluid filled space inside the eye between the iris and the innermost layer of the cornea, the endothelium). It is an essential tool in ophthalmic practice, particularly in the diagnosis of glaucoma. In 1899, the Greek ophthalmologist Alexios Trantas was the first to visualise the angle in vivo and coined the term 'gonioscopy'. He made a number of other important contributions to ophthalmology.

  9. An Experimental Technique for Structural Diagnostic Based on Laser Vibrometry and Neural Networks

    Directory of Open Access Journals (Sweden)

    Paolo Castellini

    2000-01-01

    Full Text Available In recent years damage detection techniques based on vibration data have been largely investigated with promising results for many applications. In particular, several attempts have been made to determine which kind of data should be extracted for damage monitoring.

  10. A Diagnostic Technique for Formulating Market Strategies in Higher Education Based on Relative Competitive Position.

    Science.gov (United States)

    Dolinsky, Arthur L.; Quazi, Hesan A.

    1994-01-01

    Importance-performance analysis, a marketing research technique using analysis of consumer attitudes toward salient product or service attributes, is found useful for colleges and universities in developing marketing strategies, particularly when competition is considered as an important dimension. Data are drawn from a survey of 252 students at 1…

  11. Office hysteroscopic-guided selective tubal chromopertubation: acceptability, feasibility and diagnostic accuracy of this new diagnostic non-invasive technique in infertile women.

    Science.gov (United States)

    Carta, Gaspare; Palermo, Patrizia; Pasquale, Chiara; Conte, Valeria; Pulcinella, Ruggero; Necozione, Stefano; Cofini, Vincenza; Patacchiola, Felice

    2018-06-01

    The aim of this study was to evaluate accuracy, tolerability and side effects of office hysteroscopic-guided chromoperturbations in infertile women without anaesthesia. Forty-nine infertile women underwent the procedure to evaluate tubal patency and the uterine cavity. Women with unilateral or bilateral tubal stenosis at hysteroscopy with chromoperturbation, and women with bilateral tubal patency who did not conceive during the period of six months, underwent laparoscopy with chromoperturbation. The results obtained from hysteroscopy and laparoscopy in the assessment of tubal patency were compared. Sensitivity, specificity, accuracy, positive-predictive value and negative-predictive value were used to describe diagnostic performance. Pain and tolerance were assessed during procedure using a visual analogue scale (VAS). Side effects or late complications and pregnancy rate were also recorded three and six months after the procedure. The specificity was 87.8% (95% CI: 73.80-95.90), sensitivity was 85.7% (95% CI 57.20-98.20), positive and negative predictive values were 70.6% (95% CI: 44.00-89) and 94.7% (95% CI: 82.30-99.40), respectively. Pregnancy rate (PR) within six months after performance of hysteroscopy with chromoperturbation was 27%. Office hysteroscopy-guided selective chromoperturbation in infertile patients is a valid technique to evaluate tubal patency and uterine cavity.

  12. Diagnostic reproducibility of hydatidiform moles: ancillary techniques (p57 immunohistochemistry and molecular genotyping) improve morphologic diagnosis.

    Science.gov (United States)

    Vang, Russell; Gupta, Mamta; Wu, Lee-Shu-Fune; Yemelyanova, Anna V; Kurman, Robert J; Murphy, Kathleen M; Descipio, Cheryl; Ronnett, Brigitte M

    2012-03-01

    Distinction of hydatidiform moles (HMs) from nonmolar specimens (NMs) and subclassification of HMs as complete hydatidiform moles (CHMs) and partial hydatidiform moles (PHMs) are important for clinical practice and investigational studies; yet, diagnosis based solely on morphology is affected by interobserver variability. Molecular genotyping can distinguish these entities by discerning androgenetic diploidy, diandric triploidy, and biparental diploidy to diagnose CHMs, PHMs, and NMs, respectively. Eighty genotyped cases (27 CHMs, 27 PHMs, and 26 NMs) were selected from a series of 200 potentially molar specimens previously diagnosed using p57 immunostaining and genotyping. Cases were classified by 3 gynecologic pathologists on the basis of H&E slides (masked to p57 immunostaining and genotyping results) into 1 of 3 categories (CHM, PHM, or NM) during 2 diagnostic rounds; a third round incorporating p57 immunostaining results was also conducted. Consensus diagnoses (those rendered by 2 of 3 pathologists) were determined. Genotyping results were used as the gold standard for assessing diagnostic performance. Sensitivity of a diagnosis of CHM ranged from 59% to 100% for individual pathologists and from 70% to 81% by consensus; specificity ranged from 91% to 96% for individuals and from 94% to 98% by consensus. Sensitivity of a diagnosis of PHM ranged from 56% to 93% for individual pathologists and from 70% to 78% by consensus; specificity ranged from 58% to 92% for individuals and from 74% to 85% by consensus. The percentage of correct classification of all cases by morphology ranged from 55% to 75% for individual pathologists and from 70% to 75% by consensus. The κ values for interobserver agreement ranged from 0.59 to 0.73 (moderate to good) for a diagnosis of CHM, from 0.15 to 0.43 (poor to moderate) for PHM, and from 0.13 to 0.42 (poor to moderate) for NM. The κ values for intraobserver agreement ranged from 0.44 to 0.67 (moderate to good). Addition of the p57

  13. Gel instillation sonohysterography (GIS) and saline contrast sonohysterography (SCSH): comparison of two diagnostic techniques.

    Science.gov (United States)

    Bij de Vaate, A J M; Brölmann, H A M; van der Slikke, J W; Emanuel, M H; Huirne, J A F

    2010-04-01

    To compare gel instillation sonohysterography (GIS) with saline contrast sonohysterography (SCSH) as diagnostic methods for the evaluation of the uterine cavity. A prospective cohort study was performed at the Department of Obstetrics and Gynecology of the VU University Medical Center, Amsterdam, between September 2007 and April 2008. We included 65 women suspected of having an intrauterine abnormality with an indication for SCSH/GIS. First SCSH and subsequently GIS were performed in all women. Distension of the uterine cavity, image quality, visualization of intrauterine abnormalities and pain experienced on a visual analog scale (VAS score) were recorded for both procedures. The mean distension with GIS was 9.0 mm and with SCSH it was 8.5 mm (P = 0.15). The mean image quality, on a scale from 0 to 5, for SCSH was 4.0 and for GIS it was 3.6 (P = 0.01). No difference was found for the visualization of intrauterine abnormalities, and the VAS scores for pain experienced on SCSH and GIS were 1.5 and 1.6, respectively (P = 0.62). The image quality of SCSH is slightly better than that of GIS. This difference is likely to be attributable to the presence of air bubbles in the gel. The small difference in uterine cavity distension in favor of GIS and comparable stable distension during at least 4 min make GIS a suitable alternative for SCSH if air bubbles can be prevented. Copyright 2009 ISUOG. Published by John Wiley & Sons, Ltd.

  14. Thermometric diagnosis of peripheral nerve injuries. Assessment of the diagnostic accuracy of a new practical technique.

    Science.gov (United States)

    Ya'ish, F M M; Cooper, J P; Craigen, M A C

    2007-07-01

    The diagnosis of nerve injury using thermotropic liquid crystal temperature strips was compared blindly and prospectively against operative findings in 36 patients requiring surgical exploration for unilateral upper limb lacerations with suspected nerve injury. Thermotropic liquid crystal strips were applied to affected and non-affected segments in both hands in all subjects. A pilot study showed that a simple unilateral laceration without nerve injury results in a cutaneous temperature difference between limbs, but not within each limb. Thus, for detection of a nerve injury, comparison was made against the unaffected nerve distribution in the same hand. Receiver operating characteristic curve analysis showed that an absolute temperature difference > or = 1.0 degrees C was diagnostic of a nerve injury (area under the curve = 0.985, sensitivity = 100%, specificity = 93.8%). Thermotropic liquid crystal strip assessment is a new, reliable and objective method for the diagnosis of traumatic peripheral nerve injuries. If implemented in the acute setting, it could improve the reliability of clinical assessment and reduce the number of negative surgical explorations.

  15. Use of serological diagnostic techniques in the control and eradication of caprine arthritis encephalitis: an update

    Directory of Open Access Journals (Sweden)

    Jamili Maria Suhet Mussi

    2015-12-01

    Full Text Available Caprine arthritis encephalitis (CAE is a chronic disease caused by a small ruminant lentivirus (SRLV, which causes significant losses in goat breeding. The actual state of animal infection with SRLV is difficult to determine due to a complex pathogenesis of the virus, including factors such as delayed or intermittent seroconversion in serological tests. Several serological techniques are available for disease diagnosis, such as screening or confirmation tests, which are different in sensitivity and specificity. Regarding the choice of the test to be applied, availability of commercial immunoreagents, team training, antigen used, and cost of techniques must be considered. This review presents the serological methods available for use in different stages of CAE control and eradication programs, and management measures to be adopted in conjunction with serological diagnosis of the disease.

  16. Diagnosis of soil-transmitted helminthiasis in an Amazonic community of Peru using multiple diagnostic techniques.

    Science.gov (United States)

    Machicado, Jorge D; Marcos, Luis A; Tello, Raul; Canales, Marco; Terashima, Angelica; Gotuzzo, Eduardo

    2012-06-01

    An observational descriptive study was conducted in a Shipibo-Conibo/Ese'Eja community of the rainforest in Peru to compare the Kato-Katz method and the spontaneous sedimentation in tube technique (SSTT) for the diagnosis of intestinal parasites as well as to report the prevalence of soil-transmitted helminth (STH) infections in this area. A total of 73 stool samples were collected and analysed by several parasitological techniques, including Kato-Katz, SSTT, modified Baermann technique (MBT), agar plate culture, Harada-Mori culture and the direct smear examination. Kato-Katz and SSTT had the same rate of detection for Ascaris lumbricoides (5%), Trichuris trichiura (5%), hookworm (14%) and Hymenolepis nana (26%). The detection rate for Strongyloides stercoralis larvae was 16% by SSTT and 0% by Kato-Katz, but 18% by agar plate culture and 16% by MBT. The SSTT also had the advantage of detecting multiple intestinal protozoa such as Blastocystis hominis (40%), Giardia intestinalis (29%) and Entamoeba histolytica/E. dispar (16%). The most common intestinal parasites found in this community were B. hominis, G. intestinalis, H. nana, S. stercoralis and hookworm. In conclusion, the SSTT is not inferior to Kato-Katz for the diagnosis of common STH infections but is largely superior for detecting intestinal protozoa and S. stercoralis larvae. Copyright © 2012 Royal Society of Tropical Medicine and Hygiene. Published by Elsevier Ltd. All rights reserved.

  17. Analysis of relaxing laser-induced plasmas by absorption spectroscopy: Toward a new quantitative diagnostic technique

    International Nuclear Information System (INIS)

    Ribiere, M.; Cheron, B.G.

    2010-01-01

    Broad-band near UV absorption spectroscopy was used to analyze atmospheric laser-induced plasmas formed on metallic and refractory targets. When the common emission spectroscopy only provides the density of the radiating atomic excited states, the technique reported in this paper is able to achieve high spatial resolution in the measurement of absolute number densities in expanding laser-induced plasmas. The reliability and the versatility of this technique, which is based on the comparison between results of the numerical integration of the radiative transfer equation and experimental spectra, were tested on different targets. The evolutions in time and space of the absolute population of the plasma species originating from metallic alloys (Al-Mg and Cu-Ni) and refractory materials (C/SiC) were achieved over large time scales. Owing to its accuracy, this absorption technique (that we call 'LIPAS' for Laser Induced Plasma Absorption Spectroscopy) should bring a new and enhanced support to the validation of collisional-radiative models attempting to provide reliable evolutions of laser-induced plasmas.

  18. New diagnostic and therapeutic techniques in the management of pyogenic liver abscesses

    International Nuclear Information System (INIS)

    Ranson, J.H.C.; Madayag, M.A.; Localio, S.A.; Spencer, F.C.

    1975-01-01

    An unexplained increase in the frequency of pyogenic liver abscesses of unknown etiology has, fortunately, been paralleled by significant advances in diagnostic and therapeutic methods. This report reviews experience with 14 patients operated upon at NYU Medical Center since 1971. Eight cases (57 percent) were cryptogenic. Other abscesses were associated with biliary disease (3); abdominal sepsis (2); and trauma (1). Abscesses were present on hospitalization in 12 patients. Clinical findings included fever (101 to 108 F), 100 percent; leucocytosis, 71 percent; anorexia and vomiting, 50 percent; localized tenderness and hepatomegaly, 50 percent; hypoalbuminemia; 86 percent; hypocholesterolemia, 78 percent; elevated SGOT, 71 percent; and elevated aikaline phosphatase, 43 percent. Technetium hepatic scintiscans showed focal defects in 10 of 12 patients (83 percent), but did not detect multiple abscesses in 2 of these. Hepatic arteriography performed in 10 patients was highly accurate, outlining single abscesses in 6 and multiple abscesses in 4. Furthermore, in one patient a false positive scintiscan was demonstrated by negative arteriography, confirmed by autopsy. In 4 patients, arteriography indicated an abscess in the posterior-superior area of the right hepatic lobe. With precise anatomical localization, a transthoracic approach permitted uncomplicated drainage in each case. This approach provides excellent exposure and direct drainage for abscesses in this area. An additional therapeutic adjunct in two patients, with 4 and 11 abscesses each, was postoperative intraportal infusion of antibiotics through the umbilical vein. Thirteen patients (83 percent) recovered, one dying from pulmonary embolism. Primary hepatic abscesses occur with increasing frequency. The methods described allow more precise preoperative diagnosis and direct surgical drainage

  19. Literature systematic review on the ophthalmological side effects of interferons

    Directory of Open Access Journals (Sweden)

    Yara Dadalti Fragoso

    2011-08-01

    Full Text Available Interferons alpha and beta have been used worldwide for a few decades, altering the natural history of several severe diseases including hepatitis C, cancer and immune-mediated conditions such as multiple sclerosis. The adverse events profile of interferons is well established, but only isolated reports of ophthalmological complications of interferon therapy have been published. The objective of this study was to carry out a literature systematic review on the subject, bringing to light the need for careful ophthalmological monitoring of patients undergoing interferon treatment. Nearly 500 cases of ophthalmological complications related to interferon have been reported. The most frequent findings were soft exudates, hemorrhages and retina ischemia.

  20. Four-hour processing of clinical/diagnostic specimens for electron microscopy using microwave technique.

    Science.gov (United States)

    Giberson, R T; Demaree, R S; Nordhausen, R W

    1997-01-01

    A protocol for routine 4-hour microwave tissue processing of clinical or other samples for electron microscopy was developed. Specimens are processed by using a temperature-restrictive probe that can be set to automatically cycle the magnetron to maintain any designated temperature restriction (temperature maximum). In addition, specimen processing during fixation is performed in 1.7-ml microcentrifuge tubes followed by subsequent processing in flow-through baskets. Quality control is made possible during each step through the addition of an RS232 port to the microwave, allowing direct connection of the microwave oven to any personal computer. The software provided with the temperature probe enables the user to monitor time and temperature on a real-time basis. Tissue specimens, goat placenta, mouse liver, mouse kidney, and deer esophagus were processed by conventional and microwave techniques in this study. In all instances, the results for the microwave-processed samples were equal to or better than those achieved by routine processing techniques.

  1. Comparison of different diagnostic techniques for the detection of cryptosporidiosis in bovines

    Directory of Open Access Journals (Sweden)

    H. K. M. Rekha

    2016-02-01

    Full Text Available Aim: Aim of the present study was to compare different methods, viz., Sheather’s sugar flotation (SSF, Ziehl-Neelsen (ZN, Kinyoun’s acid-fast method (KAF, safranin-methylene blue staining (SMB, and negative staining techniques such as nigrosin staining, light green staining, and malachite green staining for the detection of Cryptosporidium spp. oocysts in bovines. Materials and Methods: A total of 455 fecal samples from bovines were collected from private, government farms and from the clinical cases presented to Department of Medicine, Veterinary College, Bengaluru. They were subjected for SSF, ZN, KAF, SMB and negative staining methods. Results: Out of 455 animal fecal samples screened 5.71% were found positive for Cryptosporidium spp. oocysts. The species were identified as Cryptosporidium parvum in calves and Cryptosporidium andersoni in adults based on the morphological characterization and micrometry of the oocysts. Conclusions: Of all the techniques, fecal flotation with sheather’s was found to be more specific and sensitive method for the detection of Cryptosporidium spp. oocysts. Among the conventional staining methods, the SMB gives better differentiation between oocysts and yeast. Among the three negative staining methods, malachite green was found sensitive over the other methods.

  2. Sensitivity of diagnostic techniques in determining the prevalence of anuran trypanosomes.

    Science.gov (United States)

    Woo, P T

    1983-01-01

    Two hundred thirty-three leopard frogs (Rana pipiens) from Oshkosh, Wisconsin, USA, were divided into two groups and their blood examined for trypanosomes. In Group I (n = 157), where the blood was examined by the hematocrit centrifuge technique (HCT), 36 (23%) were infected with trypanosomes. Eighteen were infected with Trypanosoma pipientis, 13 with Trypanosoma ranarum, three with Trypanosoma rotatorium and two with mixed infections of T. pipientis and T. ranarum. In Group II (n = 76) the blood was cultured and also examined by HCT and wet mounts. Trypanosomes (T. pipientis and T. ranarum) were detected in 24 frogs (33%) using all three techniques. Eleven T. pipientis were detected by HCT, however none by culture and two by wet mounts. Twelve T. ranarum were detected by culture while only 10 were found by HCT and five by wet mounts. One T. ranarum infection detected by HCT was missed by culture because of bacterial contamination. The HCT was consistently better than wet mount examinations. It is suggested that the HCT be used whenever possible in future trypanosome surveys.

  3. Diagnostic performance of MRI measurements to assess hindfoot malalignment. An assessment of four measurement techniques

    International Nuclear Information System (INIS)

    Buck, Florian M.; Hoffmann, Adrienne; Mamisch-Saupe, Nadja; Hodler, Juerg; Farshad, Mazda; Espinosa, Norman; Resnick, Donald

    2013-01-01

    To investigate the ability of coronal non-weight-bearing MR images to discriminate between normal and abnormal hindfoot alignment. Three different measurement techniques (calcaneal axis, medial/lateral calcaneal contour) based on weight-bearing hindfoot alignment radiographs were applied in 49 patients (mean, 48 years; range 21-76 years). Three groups of subjects were enrolled: (1) normal hindfoot alignment (0 -10 valgus); (2) abnormal valgus (>10 ); (3) any degree of varus hindfoot alignment. Hindfoot alignment was then measured on coronal MR images using four different measurement techniques (calcaneal axis, medial/lateral calcaneal contour, sustentaculum tangent). ROC analysis was performed to find the MR measurement with the greatest sensitivity and specificity for discrimination between normal and abnormal hindfoot alignment. The most accurate measurement on MR images to detect abnormal hindfoot valgus was the one using the medial calcaneal contour, reaching a sensitivity/specificity of 86 %/75 % using a cutoff value of >11 valgus. The most accurate measurement on MR images to detect abnormal hindfoot varus was the sustentaculum tangent, reaching a sensitivity/specificity of 91 %/71 % using a cutoff value of <12 valgus. It is possible to suspect abnormal hindfoot alignment on coronal non-weight-bearing MR images. (orig.)

  4. Towards non-invasive diagnostic techniques for early detection of acute renal transplant rejection: A review

    Directory of Open Access Journals (Sweden)

    Elizabeth Hollis

    2017-03-01

    Full Text Available The kidney is a very important complicated filtering organ of the body. When the kidney reaches stage 5 chronic kidney disease, end stage renal failure, the preeminent therapy is renal transplantation. Although it is the best form of treatment, lack of kidney donors is still challenging. Therefore, all efforts should be employed to prolong the survival rate of the transplanted kidney. However, graft dysfunction (e.g., acute rejection is one of the serious barriers to long term kidney transplant survival. Currently, graft dysfunction’s gold standard of diagnosis is renal biopsy. Although renal biopsy is helpful, it is not preferred due to its invasive nature, high morbidity rates, and expensiveness. Therefore, noninvasive imaging techniques have become the subject of extensive research and interest, giving a strong promise to replace, or at least to decrease, biopsy usage in diagnosing graft dysfunction. This survey will discuss not only the current diagnosis and treatment of graft dysfunction but also the state-of-the-art imaging techniques in detecting acute renal transplant rejection.

  5. Diagnostic performance of MRI measurements to assess hindfoot malalignment. An assessment of four measurement techniques

    Energy Technology Data Exchange (ETDEWEB)

    Buck, Florian M.; Hoffmann, Adrienne; Mamisch-Saupe, Nadja; Hodler, Juerg [University Hospital Balgrist and University of Zurich, Radiology, Zuerich (Switzerland); Farshad, Mazda; Espinosa, Norman [University Hospital Balgrist and University of Zurich, Department of Orthopaedic Surgery, Zuerich (Switzerland); Resnick, Donald [University of California San Diego, Department of Radiology, San Diego, CA (United States)

    2013-09-15

    To investigate the ability of coronal non-weight-bearing MR images to discriminate between normal and abnormal hindfoot alignment. Three different measurement techniques (calcaneal axis, medial/lateral calcaneal contour) based on weight-bearing hindfoot alignment radiographs were applied in 49 patients (mean, 48 years; range 21-76 years). Three groups of subjects were enrolled: (1) normal hindfoot alignment (0 -10 valgus); (2) abnormal valgus (>10 ); (3) any degree of varus hindfoot alignment. Hindfoot alignment was then measured on coronal MR images using four different measurement techniques (calcaneal axis, medial/lateral calcaneal contour, sustentaculum tangent). ROC analysis was performed to find the MR measurement with the greatest sensitivity and specificity for discrimination between normal and abnormal hindfoot alignment. The most accurate measurement on MR images to detect abnormal hindfoot valgus was the one using the medial calcaneal contour, reaching a sensitivity/specificity of 86 %/75 % using a cutoff value of >11 valgus. The most accurate measurement on MR images to detect abnormal hindfoot varus was the sustentaculum tangent, reaching a sensitivity/specificity of 91 %/71 % using a cutoff value of <12 valgus. It is possible to suspect abnormal hindfoot alignment on coronal non-weight-bearing MR images. (orig.)

  6. New analysis methods to push the boundaries of diagnostic techniques in the environmental sciences

    International Nuclear Information System (INIS)

    Lungaroni, M.; Peluso, E.; Gelfusa, M.; Malizia, A.; Talebzadeh, S.; Gaudio, P.; Murari, A.; Vega, J.

    2016-01-01

    In the last years, new and more sophisticated measurements have been at the basis of the major progress in various disciplines related to the environment, such as remote sensing and thermonuclear fusion. To maximize the effectiveness of the measurements, new data analysis techniques are required. First data processing tasks, such as filtering and fitting, are of primary importance, since they can have a strong influence on the rest of the analysis. Even if Support Vector Regression is a method devised and refined at the end of the 90s, a systematic comparison with more traditional non parametric regression methods has never been reported. In this paper, a series of systematic tests is described, which indicates how SVR is a very competitive method of non-parametric regression that can usefully complement and often outperform more consolidated approaches. The performance of Support Vector Regression as a method of filtering is investigated first, comparing it with the most popular alternative techniques. Then Support Vector Regression is applied to the problem of non-parametric regression to analyse Lidar surveys for the environments measurement of particulate matter due to wildfires. The proposed approach has given very positive results and provides new perspectives to the interpretation of the data.

  7. [A study of the value of three molecular diagnostic techniques in the diagnosis of tuberculosis].

    Science.gov (United States)

    Huang, Fang; Dang, Liyun; Sun, Huiping; Yang, Han; Wu, Xia

    2015-09-01

    To evaluate the diagnostic value of real-time fluorescent RNA isothermal amplification detection technology (simultaneous amplification and testing, SAT), Mycobacterium nucleic acid detection (PCR-fluorescence probe)method (TB-NTM-PCR) and Xpert MTB/RIF detection in the diagnosis of tuberculosis. A total of 378 sputum specimens from pulmonary tuberculosis patients were collected between April to July 2014 in Xi'an Thoracic Tumor and Tuberculosis Hospital. The specimens were detected by 5 methods at the same time including acid-fast stain, SAT method, TB-NTM-PCR method, TB 960 rapid liquid culture and Xpert MTB/RIF. The sensitivity and specificity of SAT method, TB-NTM-PCR method and Xpert MTB/RIF were calculated according to the results of TB 960 rapid liquid culture and staining. The difference among all the 3 methods was analyzed by Chi-squared test. The positive rate of SAT-TB,TB-NTM-PCR and Xpert MTB/RIF were 37.6% (142/378), 37.8% (143/378) and 53.4% (202/378), respectively. In specimens both positive for acid-fast stain and culture, the positive rate of SAT method was 84.6% (77/91), that of TB-NTM-PCR was 91.2% (83/91), and that of Xpert MTB/RIF was 96.7% (88/91), the difference being significant (P=0.018 2). In specimens negative for acid-fast stain but positive for culture, the positive rate of SAT method was 61.9% (60 /97), that of TB-NTM-PCR was 44.3% (43/97), and that of Xpert MTB/RIF was 80.4% (78/97), the difference being significant (Pmolecular detection methods showed good results for the auxiliary diagnosis of tuberculosis. Xpert MTB/RIF had the best performance both in smear positive and negative specimens and it can detect rifampicin related rpoB gene mutations at the same time.

  8. MR-defecography in obstructed defecation syndrome (ODS): technique, diagnostic criteria and grading.

    Science.gov (United States)

    Piloni, V; Tosi, P; Vernelli, M

    2013-10-01

    The aim of this study was to evaluate the use of a magnetic resonance (MR)-based classification system of obstructive defecation syndrome (ODS) to guide physicians in patient management. The medical records and imaging series of 105 consecutive patients (90 female, 15 male, aged 21-78 years, mean age 46.1 ± 5.1 years) referred to our center between April 2011 and January 2012 for symptoms of ODS were retrospectively examined. After history taking and a complete clinical examination, patients underwent MR imaging according to a standard protocol using a 0.35 T permanent field, horizontally oriented open-configuration magnet. Static and dynamic MR-defecography was performed using recognized parameters and well-established diagnostic criteria. Sixty-seven out of 105 (64 %) patients found the prone position more comfortable for the evacuation of rectal contrast while 10/105 (9.5 %) were unable to empty their rectum despite repeated attempts. Increased hiatus size, anterior rectocele and focal or extensive defects of the levator ani muscle were the most frequent abnormalities (67.6, 60.0 and 51.4 %, respectively). An MR-based classification was developed based on the combinations of abnormalities found: Grade 1 = functional abnormality, including paradoxical contraction of the puborectalis muscle, without anatomical defect affecting the musculo-fascial structures; Grade 2 = functional defect associated with a minor anatomical defect such as rectocele ≤ 2 cm in size and/or first-degree intussusception; Grade 3 = severe defects confined to the posterior anatomical compartment, including >2 cm rectocele, second- or higher-degree intussusception, full-thickness external rectal prolapse, poor mesorectal posterior fixation, rectal descent >5 cm, levator ani muscle rupture, ballooning of the levator hiatus and focal detachment of the endopelvic fascia; Grade 4 = combined defects of two or three pelvic floor compartments, including cystocele, hysterocele, enlarged urogenital

  9. Sportsmen's Groin-Diagnostic Approach and Treatment With the Minimal Repair Technique: A Single-Center Uncontrolled Clinical Review.

    Science.gov (United States)

    Muschaweck, Ulrike; Berger, Luise Masami

    2010-05-01

    Sportsmen's groin, also called sports hernia and Gilmore groin, is one of the most frequent sports injuries in athletes and may place an athletic career at risk. It presents with acute or chronic groin pain exacerbated with physical activity. So far, there is little consensus regarding pathogenesis, diagnostic criteria, or treatment. There have been various attempts to explain the cause of the groin pain. The assumption is that a circumscribed weakness in the posterior wall of the inguinal canal, which leads to a localized bulge, induces a compression of the genital branch of the genitofemoral nerve, considered responsible for the symptoms. The authors developed an innovative open suture repair-the Minimal Repair technique-to fit the needs of professional athletes. With this technique, the circumscribed weakness of the posterior wall of the inguinal canal is repaired by an elastic suture; the compression on the nerve is abolished, and the cause of the pain is removed. In contrast with that of common open suture repairs, the defect of the posterior wall is not enlarged, the suture is nearly tension free, and the patient can return to full training and athletic activity within a shorter time. The outcome of patients undergoing operations with the Minimal Repair technique was compared with that of commonly used surgical procedures. THE FOLLOWING ADVANTAGES OF THE MINIMAL REPAIR TECHNIQUE WERE FOUND: no insertion of prosthetic mesh, no general anesthesia required, less traumatization, and lower risk of severe complications with equal or even faster convalescence. In 2009, a prospective cohort of 129 patients resumed training in 7 days and experienced complete pain relief in an average of 14 days. Professional athletes (67%) returned to full activity in 14 days (median). The Minimal Repair technique is an effective and safe way to treat sportsmen's groin.

  10. A hybrid body technique: does the pulse diagnostic cun guan chi method have Chinese-Tibetan origins?

    Science.gov (United States)

    Hsu, Elisabeth

    2008-01-01

    This article investigates the medieval origins of the main pulse diagnostic method in contemporary Chinese medicine, sometimes known as san bu (three sectors) method, which requires physicians to examine the mai (vessels, vessel movements or pulse) on the wrist at the three locations cun guan chi (inch, gate, foot). The article provides evidence to suggest that this body technique grew out of an earlier Chinese one, the cun chi (inch-foot) method, which appears to have aimed at investigating the qualities of yin and yang in order to determine the condition of a patient by means of exploring fairly large areas of the patient's body surface with the palms. The article furthermore posits that the cun chi method was decisively transformed in medieval times, presumably due to the impact of early Tibetan pulse diagnostic practices: it became framed in a numerology of three and started advocating the use of the fingertips for sensing the pulse beats. The article, which draws on detailed textual analyses of medieval manuscripts, on visual evidence and also on psychophysical research, furthermore highlights how misunderstandings can constructively contribute to cultural communication.

  11. Laser diagnodent: a comparative study with other diagnostic techniques; Laser diagnodent: estudo comparativo com outras tecnicas de diagnostico

    Energy Technology Data Exchange (ETDEWEB)

    Godinho, Reugma Rego

    2002-07-01

    An evaluation of the Diagnodent equipment (Kavo Company, Germany) for the occlusal caries detection was dane through the comparison with other conventional diagnostic techniques, such as visual inspection, intra-oral micro camera and digital X-ray. The effectiveness of the equipment in the detection of hidden caries and its viability as a diagnosis method for caries in their initial stage was also studied. Fifty eight permanent molars and premolars teeth from patients with age between 6 and 30 years were studied. The obtained results indicated that the conventional methods employed for the caries diagnosis are unable to detect the carious lesion in its initial stage. The Diagnodent equipment has this capability to detect caries presenting a flawless surface, specially the hidden caries, allowing the dentist to decide between a preventive ar a conservative procedure. The main advantage of the Diagnodent is to be an objective method, compared to the visual and radiographic ones, that are dependent on the professional interpretation. The Diagnodent is, therefore, a promising alternative as an objective and standardized diagnosis method for the final diagnostic. (author)

  12. Diagnostic accuracy of magnetic resonance imaging techniques for treatment response evaluation in patients with head and neck tumors, a systematic review and meta-analysis

    NARCIS (Netherlands)

    van der Hoorn, Anouk; van Laar, Peter Jan; Holtman, Gea A.; Westerlaan, Henriette E.

    2017-01-01

    Background Novel advanced MRI techniques are investigated in patients treated for head and neck tumors as conventional anatomical MRI is unreliable to differentiate tumor from treatment related imaging changes. Purpose As the diagnostic accuracy of MRI techniques to detect tumor residual or

  13. Cardiovascular dysfunction in obesity and new diagnostic imaging techniques: the role of noninvasive image methods.

    Science.gov (United States)

    Barbosa, José Augusto A; Rodrigues, Alexandre B; Mota, Cleonice Carvalho C; Barbosa, Márcia M; Simões e Silva, Ana C

    2011-01-01

    Obesity is a major public health problem affecting adults and children in both developed and developing countries. This condition often leads to metabolic syndrome, which increases the risk of cardiovascular disease. A large number of studies have been carried out to understand the pathogenesis of cardiovascular dysfunction in obese patients. Endothelial dysfunction plays a key role in the progression of atherosclerosis and the development of coronary artery disease, hypertension and congestive heart failure. Noninvasive methods in the field of cardiovascular imaging, such as measuring intima-media thickness, flow-mediated dilatation, tissue Doppler, and strain, and strain rate, constitute new tools for the early detection of cardiac and vascular dysfunction. These techniques will certainly enable a better evaluation of initial cardiovascular injury and allow the correct, timely management of obese patients. The present review summarizes the main aspects of cardiovascular dysfunction in obesity and discusses the application of recent noninvasive imaging methods for the early detection of cardiovascular alterations.

  14. [Hypercoagulable workup in ophthalmology. When and what].

    Science.gov (United States)

    Muñoz-Negrete, F J; Casas-Lleras, P; Pérez-López, M; Rebolleda, G

    2009-07-01

    Most ophthalmologic disorders secondary to hypercoagulabe state are due to the confluence of congenital and adquired factors. A systematic workup is mandatory. Most of congenital coagulation disorders cause venous trombosis and are inherited autosomal dominantly. In order of frequency these are factor V Leiden mutation (activated protein C resistance), G20210A mutation of the prothrombin gen and protein C, protein S, and antithrombin III deficiencies. Sickle cell anemia can determine arerial and venous thrombosis. In relation with arterial occlusion, the markers most frequently involved are homcysteine fasting levels and the markers of antiphospholipid antibody syndrome. Both of them can also determine venous thrombosis. Several acquired factors can lead to hypoercoagulable state, especially hyperhomocysteinemia, antiphospholipid antibody syndrome, hepatic disease, alcohol and tobacco intake, oral contraceptives, immobilization, surgeries and malignancies. In central venous occlusion is only necessary to rule out hyperhomocysteinemia and antiphospholipid antibody syndrome in young patients without known risk factors. In central artery occlusion, hypercoagulable workup is only recommended for patients less than 50 years-old with unknown emboli source. In this cases protein C, protein S, and antithrombin III deficiencies, homocystein, sickle cell disease and antiphospholipid antibody syndrome will ruled out. In non arteritic ischemic optic neuropathy hypercoagulable work up is not necessary. In amaurosis fugax without known emboli source, it is recommended to rule out etiologies of arterial occlusion, especially antithrombin III deficiencies, homocystein, sickle cell disease and antiphospholipid antibody syndrome.

  15. Danish Ophthalmology - from start to 1865.

    Science.gov (United States)

    Norn, Mogens

    2016-03-01

    This short paper mentioned the medical treatment using the 'holy' springs, the first 'eye doctor' in Denmark, the first picture of spectacles which was found in Viborg Cathedral of the high priest before he performs circumcisio praeputii on Jesus Christ, further cataract reclination in Denmark from around year zero and cataract extraction in 1667 in Denmark on a goose by Francisco Borri and on humans by the Danish Georg Heuermann in 1755. Epidemic military eye diseases in 1807, 1856 and 1865 are also described in this study. From 1856, a new ophthalmological period started in Denmark with the first eye hospital (lazaret only for eye diseases), and in 1864, patients with eye diseases were transported from the few beds in the surgical departments in the municipal hospital to the first civil eye department in Denmark, the eye hospital Sct. Annae in Copenhagen. The new scientific period started with Jacob Christian Bentz (ophthalmia granulosa, joint editor of the Danish Medical Journal) and Heinrich Lehmann. © 2016 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  16. Lasers in ophthalmology: achievements and new directions

    Science.gov (United States)

    Carstocea, Benone D.; Apostol, Silvia; Gafencu, Otilia L.

    1995-03-01

    The main characteristics of the laser radiations are: directivity, monochromaticity and spatially and temporally coherence. Using the aggregation state as a criterion for classification, we describe solid, liquid and gaseous active media. Concerning the methods used to realize the population inversion, we also describe: optically, electrically and high energy particles pumped lasers. Depending on the laser media and the mode of excitation, a laser may operate in multiple ways: the continuous-wave operation, the long-pulsed operation, the Q-switched mode of operation and the mode-locked operation. The interaction of laser radiations with the living matter is based upon four main effects: the thermal, mechanical, electrical and biological effect. The main field of therapeutical use of lasers are: the management of lid tumors and intraocular tumors, dacryocystorhinostomy, the treatment of diabetic retinopathy, thromboembolic retinal syndromes, inflammatory choriretinal disease, chorioroetinal degenerations, retinal angimatosis, retinal breaks and retinal detachment, corneal diseases, glaucoma, lens diseases. Laser has also nontherapeutical applications in diagnosis and prognosis of ophthalmologic diseases.

  17. Diagnostic accuracy of dynamic contrast-enhanced MR imaging of renal masses with rapid-acquisition spin-echo technique

    International Nuclear Information System (INIS)

    Eilenberg, S.S.; Lee, J.K.T.; Brown, J.J.; Heiken, J.P.; Mirowitz, S.A.

    1990-01-01

    This paper compares the diagnostic accuracy of Gd-DTPA-enhanced rapid-acquisition spin-echo (RASE) imaging with standard spin-echo techniques for detecting renal cysts and solid renal neoplasms. RASE imaging combines a short TR (275 msec)/short TE (10 msec), single excitation pulse sequence with half-Fourier data sampling. Eighteen patients with CT evidence of renal masses were first evaluated with standard T1-and T2-weighted SE sequences. Pre- and serial postcontrast (Cd-DTPA, 0.1 mmol./kg) RASE sequences were then performed during suspended respiration. A final set of postcontrast images was obtained with the standard T1-weighted SE sequence. Each set of MR images was first reviewed separately (ie, T1, T2, pre- and post-contrast RASE, etc)

  18. Diagnostic value of renal clearance techniques using iodo-hippuran /sup 131/I and /sup 99m/-DTPA

    Energy Technology Data Exchange (ETDEWEB)

    Heidenreich, P; Hoer, G [Technische Univ. Muenchen (Germany, F.R.). Nuklearmedizinische Klinik und Poliklinik

    1976-01-01

    Methods and clinical indications of divided renal clearance determination using /sup 131/I-hippuran are presented and their value as a diagnostic tool in urology is shown by two case reports. For quantitative assessment of renal function we prefer the whole body clearance (with partial shielding of kidneys and bladder) which obviates the necessity of the theoretical assumption of compartmental distribution of radiopharmaceuticals. Using simplified clearance techniques only based on analysis of plasma disappearance curves (slope clearance one- and two-compartment model), clinically useful results are also obtainable, especially in follow up studies. The evaluation of tubular and glomerular kidney function by simultaneous application of /sup 131/I-hippuran and sup(99m)Tc-DTPA is suitable for estimation of filtration fraction in patients with urological and nephrological diseases. Even with regard to therapy and follow up studies of urinary tract tuberculosis, remarkable dignostic informations may be achieved.

  19. Modern endoscopic techniques of precancerous stomach conditions diagnostics: problems and possibilities

    Directory of Open Access Journals (Sweden)

    Yu.M. Stepanov

    2017-02-01

    (in the antrum, along the small curvature of the stomach diffusely. According to the researchers’ data, the presence of the intestinal metaplasia on the lesser curvature of the stomach has a strong association with cancer risk. The different kinds of endoscopic devices allow diagnostically diffentiate atrophy and intestinal metaplasia of the stomach. Endoscopy white light can’t reliably diagnose stomach precancerous changes, while videoendoscopy with magnifications and narrow band imaging (NBI, according to researchers’ data, significantly improves the diagnosis of this disease. The basis of diagnosis is increasing verification of two main structures: the architectonic subepithelial microvascular network microstructure and mucosal surface, which has a different pattern in the body and antral stomach. But to date there is no common classification of changes to these structures in various pathological changes. There are a large number of classifications of changes in endoscopy with NBI mode and optical zoom: Yagi (2002, M. Dinis-Ribeiro (2003, G.K. Anagnostopoulos et al. (2007, T. Tahara (2009, P. Pimentel-Nunes, M. Dinis-Ribeiro (2012. It is noted that the problem is that NBI with zoom is practically impossible to use in daily clinical practice, the method requires a certain level of knowledge and endoscope type, available only in several centers, as well as the use of sedation for maximum effective inspection.

  20. SU-F-T-427: Utilization and Evaluation of Diagnostic CT Imaging with MAR Technique for Radiation Therapy Treatment Planning

    International Nuclear Information System (INIS)

    Xu, M; Foster, R; Parks, H; Pankuch, M

    2016-01-01

    Purpose: The objective was to utilize and evaluate diagnostic CT-MAR technique for radiation therapy treatment planning. Methods: A Toshiba-diagnostic-CT acquisition with SEMAR(Single-energy-MAR)-algorism was performed to make the metal-artifact-reduction (MAR) for patient treatment planning. CT-imaging datasets with and without SEMAR were taken on a Catphan-phantom. Two sets of CT-numbers were calibrated with the relative electron densities (RED). A tissue characterization phantom with Gammex various simulating material rods was used to establish the relationship between known REDs and corresponding CT-numbers. A GE-CT-sim acquisition was taken on the Catphan for comparison. A patient with bilateral hip arthroplasty was scanned in the radiotherapy CT-sim and the diagnostic SEMAR-CT on a flat panel. The derived SEMAR images were used as a primary CT dataset to create contours for the target, critical-structures, and for planning. A deformable registration was performed with VelocityAI to track voxel changes between SEMAR and CT-sim images. The SEMAR-CT images with minimal artifacts and high quality of geometrical and spatial integrity were employed for a treatment plan. Treatment-plans were evaluated based on deformable registration of SEMAR-CT and CT-sim dataset with assigned CT-numbers in the metal artifact regions in Eclipse v11 TPS. Results: The RED and CT-number relationships were consistent for the datasets in CT-sim and CT’s with and without SEMAR. SEMAR datasets with high image quality were used for PTV and organ delineation in the treatment planning process. For dose distribution to the PTV through the DVH analysis, the plan using CT-sim with the assigned CT-number showed a good agreement to those on deformable CT-SEMAR. Conclusion: A diagnostic-CT with MAR-algorithm can be utilized for radiotherapy treatment planning with CT-number calibrated to the RED. Treatment planning comparison and DVH shows a good agreement in the PTV and critical organs between

  1. COMPUTER LEARNING SIMULATOR WITH VIRTUAL REALITY FOR OPHTHALMOLOGY

    Directory of Open Access Journals (Sweden)

    Valeria V. Gribova

    2013-01-01

    Full Text Available A toolset of a medical computer learning simulator for ophthalmology with virtual reality and its implementation are considered in the paper. The simulator is oriented for professional skills training for students of medical universities. 

  2. Cardiovascular dysfunction in obesity and new diagnostic imaging techniques: the role of noninvasive image methods

    Directory of Open Access Journals (Sweden)

    Barbosa JA

    2011-05-01

    Full Text Available José Augusto A Barbosa¹, Alexandre B Rodrigues¹, Cleonice Carvalho C Mota¹, Márcia M Barbosa², Ana C Simões e Silva¹¹Department of Pediatrics, Faculty of Medicine, Federal University of Minas Gerais (UFMG, Belo Horizonte, Minas Gerais, Brazil; ²Ecocenter, Socor Hospital, Belo Horizonte, Minas Gerais, BrazilAbstract: Obesity is a major public health problem affecting adults and children in both developed and developing countries. This condition often leads to metabolic syndrome, which increases the risk of cardiovascular disease. A large number of studies have been carried out to understand the pathogenesis of cardiovascular dysfunction in obese patients. Endothelial dysfunction plays a key role in the progression of atherosclerosis and the development of coronary artery disease, hypertension and congestive heart failure. Noninvasive methods in the field of cardiovascular imaging, such as measuring intima-media thickness, flow-mediated dilatation, tissue Doppler, and strain, and strain rate, constitute new tools for the early detection of cardiac and vascular dysfunction. These techniques will certainly enable a better evaluation of initial cardiovascular injury and allow the correct, timely management of obese patients. The present review summarizes the main aspects of cardiovascular dysfunction in obesity and discusses the application of recent noninvasive imaging methods for the early detection of cardiovascular alterations.Keywords: cardiovascular risk, endothelium dysfunction, obesity, strain and strain rate, tissue Doppler

  3. Foetal radiography for suspected skeletal dysplasia: technique, normal appearances, diagnostic approach

    Energy Technology Data Exchange (ETDEWEB)

    Calder, Alistair D. [Great Ormond Street Hospital for Children NHS Foundation Trust, Radiology Department, London (United Kingdom); Offiah, Amaka C. [Sheffield Children' s NHS Foundation Trust, Academic Unit of Child Health, Sheffield (United Kingdom)

    2015-04-01

    Despite advances in antenatal imaging and genetic techniques, post-delivery post-mortem foetal radiography remains the key investigation in accurate diagnosis of skeletal dysplasia manifesting in the foetus. Foetal radiography is best performed using pathology-specimen radiography equipment and is often carried out in the pathology department without involvement of the radiology unit. However, paediatric radiologists may be asked to interpret post-mortem foetal radiographs when an abnormality is suspected. Many foetal radiographs are carried out before 20 weeks' gestation, and the interpreting radiologist needs to be familiar with the range of normal post-mortem foetal appearances at different gestational ages, as well as the appearances of some of the more commonly presenting skeletal dysplasias, and will benefit from a systematic approach when assessing more challenging cases. In this pictorial essay, we illustrate various normal post-mortem foetal radiographic appearances, give examples of commonly occurring skeletal dysplasias, and describe an approach to establishing more difficult diagnoses. (orig.)

  4. A New Paradigm for Tissue Diagnostics: Tools and Techniques to Standardize Tissue Collection, Transport, and Fixation.

    Science.gov (United States)

    Bauer, Daniel R; Otter, Michael; Chafin, David R

    2018-01-01

    Studying and developing preanalytical tools and technologies for the purpose of obtaining high-quality samples for histological assays is a growing field. Currently, there does not exist a standard practice for collecting, fixing, and monitoring these precious samples. There has been some advancement in standardizing collection for the highest profile tumor types, such as breast, where HER2 testing drives therapeutic decisions. This review examines the area of tissue collection, transport, and monitoring of formalin diffusion and details a prototype system that could be used to help standardize tissue collection efforts. We have surveyed recent primary literature sources and conducted several site visits to understand the most error-prone processes in histology laboratories. This effort identified errors that resulted from sample collection techniques and subsequent transport delays from the operating room (OR) to the histology laboratories. We have therefore devised a prototype sample collection and transport concept. The system consists of a custom data logger and cold transport box and takes advantage of a novel cold + warm (named 2 + 2) fixation method. This review highlights the beneficial aspects of standardizing tissue collection, fixation, and monitoring. In addition, a prototype system is introduced that could help standardize these processes and is compatible with use directly in the OR and from remote sites.

  5. Foetal radiography for suspected skeletal dysplasia: technique, normal appearances, diagnostic approach

    International Nuclear Information System (INIS)

    Calder, Alistair D.; Offiah, Amaka C.

    2015-01-01

    Despite advances in antenatal imaging and genetic techniques, post-delivery post-mortem foetal radiography remains the key investigation in accurate diagnosis of skeletal dysplasia manifesting in the foetus. Foetal radiography is best performed using pathology-specimen radiography equipment and is often carried out in the pathology department without involvement of the radiology unit. However, paediatric radiologists may be asked to interpret post-mortem foetal radiographs when an abnormality is suspected. Many foetal radiographs are carried out before 20 weeks' gestation, and the interpreting radiologist needs to be familiar with the range of normal post-mortem foetal appearances at different gestational ages, as well as the appearances of some of the more commonly presenting skeletal dysplasias, and will benefit from a systematic approach when assessing more challenging cases. In this pictorial essay, we illustrate various normal post-mortem foetal radiographic appearances, give examples of commonly occurring skeletal dysplasias, and describe an approach to establishing more difficult diagnoses. (orig.)

  6. The Global Education Network for Retinopathy of Prematurity (Gen-Rop): Development, Implementation, and Evaluation of A Novel Tele-Education System (An American Ophthalmological Society Thesis).

    Science.gov (United States)

    Chan, R V Paul; Patel, Samir N; Ryan, Michael C; Jonas, Karyn E; Ostmo, Susan; Port, Alexander D; Sun, Grace I; Lauer, Andreas K; Chiang, Michael F

    2015-01-01

    To describe the design, implementation, and evaluation of a tele-education system developed to improve diagnostic competency in retinopathy of prematurity (ROP) by ophthalmology residents. A secure Web-based tele-education system was developed utilizing a repository of over 2,500 unique image sets of ROP. For each image set used in the system, a reference standard ROP diagnosis was established. Performance by ophthalmology residents (postgraduate years 2 to 4) from the United States and Canada in taking the ROP tele-education program was prospectively evaluated. Residents were presented with image-based clinical cases of ROP during a pretest, posttest, and training chapters. Accuracy and reliability of ROP diagnosis (eg, plus disease, zone, stage, category) were determined using sensitivity, specificity, and the kappa statistic calculations of the results from the pretest and posttest. Fifty-five ophthalmology residents were provided access to the ROP tele-education program. Thirty-one ophthalmology residents completed the program. When all training levels were analyzed together, a statistically significant increase was observed in sensitivity for the diagnosis of plus disease, zone, stage, category, and aggressive posterior ROP (Peducation system for ROP education is effective in improving diagnostic accuracy of ROP by ophthalmology residents. This system may have utility in the setting of both healthcare and medical education reform by creating a validated method to certify telemedicine providers and educate the next generation of ophthalmologists.

  7. Diagnostic radiography students' perceptions of formative peer assessment within a radiographic technique module

    International Nuclear Information System (INIS)

    Elshami, W.; Abdalla, M.E.

    2017-01-01

    Introduction: Assessment is a central part of student learning. Student involvement in peer assessment leads to significant improvement in students' performance, supports students' learning, promotes the development of evaluation skills and encourages reflection. Aim: The aim of this study is to assess perceptions of the Formative Peer Assessment (FPA) initiative within a higher education setting for undergraduate radiography students. Methods: Qualitative action research was conducted. Students were allowed to anonymously assess each other's assignments using a standardized evaluation sheet that they had been trained to use. Participants' perceptions were assessed through focus group discussion. Results: The findings showed that students' experiences with peer assessment were positive. Students acknowledged that they received valuable feedback and learned from assessing their peers. Students recommended the need for training and suggested using more than one evaluator. Conclusion: The FPA initiative in the study institution believed to be succeed as the students had a positive experience with the FPA. Students learnt from PA and from self-assessment. Implementation of PA will promote reflection and critical thinking and problem solving skills, that are important traits in radiography graduate profile as in radiography clinical practice the professional require to modify imaging techniques and critique images to ensure the quality of care. - Highlights: • Participants had a positive experience with the Formative Peer Assessment (FPA). • Students believed that the FPA had a positive impact on their learning. • FPA was time-consuming but benefits outweigh the extra time commitment. • Comprehensive training and detailed grading rubric are recommended to improve FPA.

  8. Clinical trials in Brazilian journals of ophthalmology: where we are.

    Science.gov (United States)

    Lira, Rodrigo Pessoa Cavalcanti; Leal, Franz Schubert; Gonçalves, Fauze Abdulmassih; Amorim, Fernando Henrique Ramos; Felix, João Paulo Fernandes; Arieta, Carlos Eduardo Leite

    2013-01-01

    To compare clinical trials published in Brazilian journals of ophthalmology and in foreign journals of ophthalmology with respect to the number of citations and the quality of reporting [by applying the Consolidated Standards for Reporting Trials (CONSORT) statement writing standards]. The sample of this systematic review comprised the two Brazilian journals of ophthalmology indexed at Science Citation Index Expanded and six of the foreign journals of ophthalmology with highest Impact Factor® according ISI. All clinical trials (CTs) published from January 2009 to December 2010 at the Brazilians journals and a 1:1 randomized sample of the foreign journals were included. The primary outcome was the number of citations through the end of 2011. Subgroup analysis included language. The secondary outcome included likelihood of citation (cited at least once versus no citation), and presence or absence of CONSORT statement indicators. The citation counts were statistically significantly higher (Pjournals of ophthalmology still are low when compared with the foreign journals of ophthalmology with highest Impact Factor®.

  9. The diagnostic value of double-contrast-technique cystography in the evaluation of benign and malignant lesions of the urinary bladder

    International Nuclear Information System (INIS)

    Beyer, D.; Koester, R.; Schuett, H.

    1979-01-01

    Cystography by double-contrast-technique as simple and quick method of evaluating benign and malignant lesions of the urinary bladder is being described. 301 examinations were reviewed and are being discussed in regard to diagnostic value, indication, complication and radiation exposure of this method. A few typical cases are being demonstrated to illustrate the value of this method in the spectrum of other diagnostic methods in the workup of urinary bladder lesions. (orig.) [de

  10. Neuro-ophthalmological approach to facial nerve palsy.

    Science.gov (United States)

    Portelinha, Joana; Passarinho, Maria Picoto; Costa, João Marques

    2015-01-01

    Facial nerve palsy is associated with significant morbidity and can have different etiologies. The most common causes are Bell's palsy, Ramsay-Hunt syndrome and trauma, including surgical trauma. Incidence varies between 17 and 35 cases per 100,000. Initial evaluation should include accurate clinical history, followed by a comprehensive investigation of the head and neck, including ophthalmological, otological, oral and neurological examination, to exclude secondary causes. Routine laboratory testing and diagnostic imaging is not indicated in patients with new-onset Bell's palsy, but should be performed in patients with risk factors, atypical cases or in any case without resolution within 4 months. Many factors are involved in determining the appropriate treatment of these patients: the underlying cause, expected duration of nerve dysfunction, anatomical manifestations, severity of symptoms and objective clinical findings. Systemic steroids should be offered to patients with new-onset Bell's palsy to increase the chance of facial nerve recovery and reduce synkinesis. Ophthalmologists play a pivotal role in the multidisciplinary team involved in the evaluation and rehabilitation of these patients. In the acute phase, the main priority should be to ensure adequate corneal protection. Treatment depends on the degree of nerve lesion and on the risk of the corneal damage based on the amount of lagophthalmos, the quality of Bell's phenomenon, the presence or absence of corneal sensitivity and the degree of lid retraction. The main therapy is intensive lubrication. Other treatments include: taping the eyelid overnight, botulinum toxin injection, tarsorrhaphy, eyelid weight implants, scleral contact lenses and palpebral spring. Once the cornea is protected, longer term planning for eyelid and facial rehabilitation may take place. Spontaneous complete recovery of Bell's palsy occurs in up to 70% of cases. Long-term complications include aberrant regeneration with

  11. From a genetic innovation to mass health programmes: the diffusion of Down's Syndrome prenatal screening and diagnostic techniques in France.

    Science.gov (United States)

    Vassy, Carine

    2006-10-01

    Down's Syndrome prenatal diagnostic and screening techniques have spread widely in France over the last 30 years and are now part of the routine clinical practice of prenatal care. These techniques, which originated in the field of genetics, ultrasonography and biochemistry, were the first to provide the possibility of choosing the features of the foetus, or at least to reject some of its characteristics. They lead to new norms of healthy foetuses and a progressive acceptance of medical abortions. The aim of this paper is to understand how the use of these tests has been generalised in France despite scientific controversies about their risks and ethical questioning about a potential renewal of eugenics. It analyses the representations of public needs that have been articulated by key players in the scientific and medical fields. This research explores political and administrative decision making processes to understand how progressively widening public access to prenatal testing has been organised and funded. The results highlight the scientific and political role of biomedical researchers, the forms of involvement of health authorities and politicians, and the passive participation of the vast majority of the users. The paper also examines the characteristics of the French health system that facilitated the generalised use of the technology.

  12. The problem of sexual imbalance and techniques of the self in the Diagnostic and Statistical Manual of Mental Disorders.

    Science.gov (United States)

    Flore, Jacinthe

    2016-09-01

    This article examines the problematization of sexual appetite and its imbalances in the development of the Diagnostic and Statistical Manual of Mental Disorders (DSM) in the twentieth and twenty-first centuries. The dominant strands of historiographies of sexuality have focused on historicizing sexual object choice and understanding the emergence of sexual identities. This article emphasizes the need to contextualize these histories within a broader frame of historical interest in the problematization of sexual appetite. The first part highlights how sexual object choice, as a paradigm of sexual dysfunctions, progressively receded from medical interest in the twentieth century as the clinical gaze turned to the problem of sexual appetite and its imbalances. The second part uses the example of the newly introduced Female Sexual Interest/Arousal Disorder in the DSM-5 to explore how the Manual functions as a technique for taking care of the self. I argue that the design of the Manual and associated inventories and questionnaires paved the way for their interpretation and application as techniques for self-examination. © The Author(s) 2016.

  13. Evaluation of the Acridine Orange Fluorescence Technique and the Indirect Fluorescent Antibody as Diagnostic Tests for Tropical Theileriosis

    Directory of Open Access Journals (Sweden)

    Mahmoud

    2011-06-01

    Full Text Available This study was carried out to evaluate the use of acridine orange fluorescence technique on blood slides as a rapid diagnostic test for tropical theileriosis in comparison with the Giemsa-stained thin blood film technique. Also the indirect fluorescent antibody test has been employed for the serodiagnosis of tropical theileriosis. The study was carried out on 62 young and 48 adult Friesian cattle suffering from clinical tropical theileriosis in Qassim Region, Central Saudi Arabia, during the period from August 2006 to July 2008. For control, blood samples were also obtained from 25 young and 25 adult, clinically healthy, Friesian cattle, selected at random from different dairy farms in Qassim Region. Thin blood films were fixed with methanol and stained with Giemsa and acridine orange and were examined by two independent microbiologists. There was 100% correlation in the interpretation of slides stained with Giemsa and acridine orange both with respect to positivity and negativity, between the two microbiologists. It is concluded that if facilities are available acridine orange is a valuable alternative for screening tropical theileriosis. The method may also have potential value in the diagnosis of Theileria parva, which causes East Coast fever, and also other Theileria species. Results of the present study also showed that IFA test was not found sufficiently sensitive and specific as has been reported earlier. [Vet. World 2011; 4(8.000: 341-344

  14. In-cylinder pressure-based direct techniques and time frequency analysis for combustion diagnostics in IC engines

    International Nuclear Information System (INIS)

    D’Ambrosio, S.; Ferrari, A.; Galleani, L.

    2015-01-01

    Highlights: • Direct pressure-based techniques have been applied successfully to spark-ignition engines. • The burned mass fraction of pressure-based techniques has been compared with that of 2- and 3-zone combustion models. • The time frequency analysis has been employed to simulate complex diesel combustion events. - Abstract: In-cylinder pressure measurement and analysis has historically been a key tool for off-line combustion diagnosis in internal combustion engines, but online applications for real-time condition monitoring and combustion management have recently become popular. The present investigation presents and compares different low computing-cost in-cylinder pressure based methods for the analyses of the main features of combustion, that is, the start of combustion, the end of combustion and the crankshaft angle that responds to half of the overall burned mass. The instantaneous pressure in the combustion chamber has been used as an input datum for the described analytical procedures and it has been measured by means of a standard piezoelectric transducer. Traditional pressure-based techniques have been shown to be able to predict the burned mass fraction time history more accurately in spark ignition engines than in diesel engines. The most suitable pressure-based techniques for both spark ignition and compression ignition engines have been chosen on the basis of the available experimental data. Time–frequency analysis has also been applied to the analysis of diesel combustion, which is richer in events than spark ignited combustion. Time frequency algorithms for the calculation of the mean instantaneous frequency are computationally efficient, allow the main events of the diesel combustion to be identified and provide the greatest benefits in the presence of multiple injection events. These algorithms can be optimized and applied to onboard diagnostics tools designed for real control, but can also be used as an advanced validation tool for

  15. Diagnostic techniques for viroids

    Czech Academy of Sciences Publication Activity Database

    Gucek, T.; Trdan, S.; Jakše, J.; Javornik, B.; Matoušek, Jaroslav; Radisek, S.

    2017-01-01

    Roč. 66, č. 3 (2017), s. 339-358 ISSN 0032-0862 Institutional support: RVO:60077344 Keywords : potato-spindle-tuber * multiplex rt-pcr * mediated isothermal amplification Subject RIV: EE - Microbiology, Virology OBOR OECD: Biochemistry and molecular biology Impact factor: 2.425, year: 2016

  16. Whole Genome Sequencing Increases Molecular Diagnostic Yield Compared with Current Diagnostic Testing for Inherited Retinal Disease.

    Science.gov (United States)

    Ellingford, Jamie M; Barton, Stephanie; Bhaskar, Sanjeev; Williams, Simon G; Sergouniotis, Panagiotis I; O'Sullivan, James; Lamb, Janine A; Perveen, Rahat; Hall, Georgina; Newman, William G; Bishop, Paul N; Roberts, Stephen A; Leach, Rick; Tearle, Rick; Bayliss, Stuart; Ramsden, Simon C; Nemeth, Andrea H; Black, Graeme C M

    2016-05-01

    To compare the efficacy of whole genome sequencing (WGS) with targeted next-generation sequencing (NGS) in the diagnosis of inherited retinal disease (IRD). Case series. A total of 562 patients diagnosed with IRD. We performed a direct comparative analysis of current molecular diagnostics with WGS. We retrospectively reviewed the findings from a diagnostic NGS DNA test for 562 patients with IRD. A subset of 46 of 562 patients (encompassing potential clinical outcomes of diagnostic analysis) also underwent WGS, and we compared mutation detection rates and molecular diagnostic yields. In addition, we compared the sensitivity and specificity of the 2 techniques to identify known single nucleotide variants (SNVs) using 6 control samples with publically available genotype data. Diagnostic yield of genomic testing. Across known disease-causing genes, targeted NGS and WGS achieved similar levels of sensitivity and specificity for SNV detection. However, WGS also identified 14 clinically relevant genetic variants through WGS that had not been identified by NGS diagnostic testing for the 46 individuals with IRD. These variants included large deletions and variants in noncoding regions of the genome. Identification of these variants confirmed a molecular diagnosis of IRD for 11 of the 33 individuals referred for WGS who had not obtained a molecular diagnosis through targeted NGS testing. Weighted estimates, accounting for population structure, suggest that WGS methods could result in an overall 29% (95% confidence interval, 15-45) uplift in diagnostic yield. We show that WGS methods can detect disease-causing genetic variants missed by current NGS diagnostic methodologies for IRD and thereby demonstrate the clinical utility and additional value of WGS. Copyright © 2016 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  17. Breaking bad news: A communication competency for ophthalmology training programs.

    Science.gov (United States)

    Hilkert, Sarah M; Cebulla, Colleen M; Jain, Shelly Gupta; Pfeil, Sheryl A; Benes, Susan C; Robbins, Shira L

    As the ophthalmology accreditation system undergoes major changes, training programs must evaluate residents in the 6 core competencies, including appropriately communicating bad news. Although the literature is replete with recommendations for breaking bad news across various non-ophthalmology specialties, no formal training programs exist for ophthalmology. There are many valuable lessons to be learned from our colleagues regarding this important skill. We examine the historic basis for breaking bad news, explore current recommendations among other specialties, and then evaluate a pilot study in breaking bad news for ophthalmology residents. The results of this study are limited by a small number of residents at a single academic center. Future studies from multiple training programs should be conducted to further evaluate the need and efficacy of formal communication skills training in this area, as well as the generalizability of our pilot training program. If validated, this work could serve as a template for future ophthalmology resident training and evaluation in this core competency. Copyright © 2016 Elsevier Inc. All rights reserved.

  18. Comparison of four diagnostic techniques for detection of Trichomonas vaginalis infection in females attending tertiary care hospital of North India

    Directory of Open Access Journals (Sweden)

    Razia Khatoon

    2015-01-01

    Full Text Available Background: Trichomonas vaginalis causes a common sexually transmitted disease trichomoniasis, which may lead to increased risk of transmission of human immunodeficiency virus infection and other pelvic inflammatory diseases. Wet mount examination is the most common test for diagnosis, but it has low sensitivity. Acridine orange staining can be used for diagnosis, but it requires special microscopic facility. Culture is considered as the gold standard, but it takes a long time for diagnosis. OSOM Trichomonas Rapid Test is a recently introduced rapid method based on immunochromatographic assay of trichomonal protein antigens. Hence, the present study was done to compare these four diagnostic techniques for detection of trichomoniasis in females with vaginal discharge. Materials and Methods: Vaginal swabs were taken from 835 female patients and wet mount examination, acridine orange staining, culture in Kupferberg medium, and OSOM Trichomonas Rapid Test, were performed. Results: Out of 835 patients included in our study, 68 (8.1% positive cases of trichomoniasis were detected by culture. OSOM Trichomonas Rapid Test detected 63 (7.5% cases, acridine orange staining detected 53 (6.3% cases, whereas, wet mount examination detected only 45 (5.4% positive cases. OSOM Trichomonas Rapid Test performed well and showed high sensitivity and specificity of 88.2% and 99.6%, respectively. Conclusion: As OSOM Trichomonas Rapid Test is a point of care test and gave better results than both wet mount examination and acridine orange staining; it can be used as a routine test in peripheral areas lacking laboratory facilities.

  19. Ophthalmologic Findings in Patients with Neuro-metabolic Disorders.

    Science.gov (United States)

    Jafari, Narjes; Golnik, Karl; Shahriari, Mansoor; Karimzadeh, Parvaneh; Jabbehdari, Sayena

    2018-01-01

    We aimed to present the ophthalmic manifestations of neuro-metabolic disorders. Patients who were diagnosed with neuro-metabolic disorders in the Neurology Department of Mofid Pediatric Hospital in Tehran, Iran, between 2004 and 2014 were included in this study. Disorders were confirmed using clinical findings, neuroimaging, laboratory data, and genomic analyses. All enrolled patients were assessed for ophthalmological abnormalities. A total of 213 patients with 34 different neuro-metabolic disorders were included. Ophthalmological abnormalities were observed in 33.5% of patients. Abnormal findings in the anterior segment included Kayser-Fleischer rings, congenital or secondary cataracts, and lens dislocation into the anterior chamber. Posterior segment (i.e., retina, vitreous body, and optic nerve) evaluation revealed retinitis pigmentosa, cherry-red spots, and optic atrophy. In addition, strabismus, nystagmus, and lack of fixation were noted during external examination. Ophthalmological examination and assessment is essential in patients that may exhibit neuro-metabolic disorders.

  20. 3D Printing: Print the future of ophthalmology.

    Science.gov (United States)

    Huang, Wenbin; Zhang, Xiulan

    2014-08-26

    The three-dimensional (3D) printer is a new technology that creates physical objects from digital files. Recent technological advances in 3D printing have resulted in increased use of this technology in the medical field, where it is beginning to revolutionize medical and surgical possibilities. It is already providing medicine with powerful tools that facilitate education, surgical planning, and organ transplantation research. A good understanding of this technology will be beneficial to ophthalmologists. The potential applications of 3D printing in ophthalmology, both current and future, are explored in this article. Copyright 2014 The Association for Research in Vision and Ophthalmology, Inc.

  1. Introduction to metabolomics and its applications in ophthalmology

    Science.gov (United States)

    Tan, S Z; Begley, P; Mullard, G; Hollywood, K A; Bishop, P N

    2016-01-01

    Metabolomics is the study of endogenous and exogenous metabolites in biological systems, which aims to provide comparative semi-quantitative information about all metabolites in the system. Metabolomics is an emerging and potentially powerful tool in ophthalmology research. It is therefore important for health professionals and researchers involved in the speciality to understand the basic principles of metabolomics experiments. This article provides an overview of the experimental workflow and examples of its use in ophthalmology research from the study of disease metabolism and pathogenesis to identification of biomarkers. PMID:26987591

  2. Application of smart phone on interactive teaching methods in ophthalmology

    Directory of Open Access Journals (Sweden)

    Xiao-Li Ma

    2016-06-01

    Full Text Available Smart phones as a symbol of the mobile Internet appears in college classroom, which is not only a challenge, but also a great opportunities of education information. This paper applied smart phones as the carrier of the "Internet" into ophthalmology classroom. Smart phones has a lot of features, such as rich teaching resources, diverse learning methods, flexible learning time, collating and recording capabilities and the timely, comprehensive and accurate teaching feedback so on, and could be used in case teaching and interactive teaching. The implementation of smart phones into ophthalmology classroom could inspire the learning enthusiasm of the students, enhance the quality of teaching, eventually improve teaching effects.

  3. Decision support systems and applications in ophthalmology: literature and commercial review focused on mobile apps.

    Science.gov (United States)

    de la Torre-Díez, Isabel; Martínez-Pérez, Borja; López-Coronado, Miguel; Díaz, Javier Rodríguez; López, Miguel Maldonado

    2015-01-01

    The growing importance that mobile devices have in daily life has also reached health care and medicine. This is making the paradigm of health care change and the concept of mHealth or mobile health more relevant, whose main essence is the apps. This new reality makes it possible for doctors who are not specialist to have easy access to all the information generated in different corners of the world, making them potential keepers of that knowledge. However, the new daily information exceeds the limits of the human intellect, making Decision Support Systems (DSS) necessary for helping doctors to diagnose diseases and also help them to decide the attitude that has to be taken towards these diagnoses. These could improve the health care in remote areas and developing countries. All of this is even more important in diseases that are more prevalent in primary care and that directly affect the people's quality of life, this is the case in ophthalmological problems where in first patient care a specialist in ophthalmology is not involved. The goal of this paper is to analyse the state of the art of DSS in Ophthalmology. Many of them focused on diseases affecting the eye's posterior pole. For achieving the main purpose of this research work, a literature review and commercial apps analysis will be done. The used databases and systems will be IEEE Xplore, Web of Science (WoS), Scopus, and PubMed. The search is limited to articles published from 2000 until now. Later, different Mobile Decision Support System (MDSS) in Ophthalmology will be analyzed in the virtual stores for Android and iOS. 37 articles were selected according their thematic (posterior pole, anterior pole, Electronic Health Records (EHRs), cloud, data mining, algorithms and structures for DSS, and other) from a total of 600 found in the above cited databases. Very few mobile apps were found in the different stores. It can be concluded that almost all existing mobile apps are focused on the eye's posterior

  4. Diagnostic techniques for measuring temperature transients and stress transients in the first wall of an ICF reactor

    International Nuclear Information System (INIS)

    Melamed, N.T.; Taylor, L.H.

    1983-01-01

    The primary challenge in the design of an Inertial Confinement Fusion (ICF) power reactor is to make the first wall survive the frequent explosions of the pellets. Westinghouse has proposed a dry wall design consisting of steel tubes coated with tantalum. This report describes the design of a test chamber and two diagnostic procedures for experimentally determining the reliability of the Westinghouse design. The test chamber simulates the x-ray and ion pulse irradiation of the wall due to a pellet explosion. The diagnostics consist of remote temperature sensing and surface deformation measurements. The chamber and diagnostics can also be used to test other first-wall designs

  5. Significance of head CT in neuro-ophthalmology

    International Nuclear Information System (INIS)

    Nishimoto, Yuichiro; Masuyama, Yoshimasa; Nakamura, Yasuko; Fujimoto, Toshiro.

    1979-01-01

    It is important to perform CT purposefully in patients with some neuro-ophthalmological disorders. Using Hitachi CT-H250 with the finer matrix of 256 x 256 and a section thickness of 5 mm and 10 mm, we performed head CT in 98 patients with various kinds of neuro-ophthalmological disorders in these 30 months. Neuro-ophthalmological findings in these patients were visual disturbance, visual field defects (hemianopsia, quandrantanopsia, enlargement of the blind spot, central scotoma), papilledema, optic nerve atrophy, difficulties in ocular movements, and others. In 44 (44.9%) of these 98 patients, abnormal findings were displayed in the head CT, characterizing intracranial tumors, intracranial infarction, aneurysms in intracranial vessels, arterio-venous malformation, enlargement of the ventricle or the cistern. In some cases the head CT was the decisive procedure in ensuring a correct diagnosis. We presented findings in the head CT in several interesting cases. We recognized the necessity of the head CT in patients with neuro-ophthalmological disorders. (author)

  6. What is new in recommendations on ophthalmological screening in ...

    African Journals Online (AJOL)

    ... complication-toxic retinopathy. The present recommendations warn against making premature decision on medicine withdrawal, especially in the light of the most recent studies on their beneficial systemic influence. This paper systematizes the information on ophthalmological screening in chloroquine derivatives users.

  7. Impact of fellowship training on research productivity in academic ophthalmology.

    Science.gov (United States)

    Huang, Grace; Fang, Christina H; Lopez, Santiago A; Bhagat, Neelakshi; Langer, Paul D; Eloy, Jean Anderson

    2015-01-01

    To assess whether scholarly impact of academic ophthalmologists, as measured using the h-index, is affected by fellowship training status and to further characterize differences in productivity among the various subspecialties and by departmental rank. A descriptive and correlational design was used. In total, 1440 academic ophthalmologists from 99 ophthalmology training programs were analyzed. The h-index data were obtained from the Scopus database. Faculty members were classified by academic rank and grouped into 10 categories based on fellowship training: anterior segment, corneal and external disease, glaucoma, uveitis and ocular immunology, vitreoretinal disease, ophthalmic plastic surgery, pediatric ophthalmology, neuro-ophthalmology, ophthalmic pathology, and "other." A one-way analysis of variance or Student t test using Microsoft Excel and "R" statistical software were used for comparison of continuous variables, with significance set at p productivity, as measured using the h-index, than non-fellowship-trained ophthalmologists in this study (p productivity compared with those in other ophthalmology subspecialties (p productivity with increasing academic rank from Assistant Professor to Professor (p productivity between fellowship-trained and non-fellowship-trained ophthalmologists existed individually only at the level of Assistant Professor (p productivity increases with departmental academic rank from Assistant Professor to Professor. Copyright © 2015 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.

  8. Ophthalmology programs at ABCC. A brief review and preliminary plan

    Energy Technology Data Exchange (ETDEWEB)

    Finch, S C; Jablon, S

    1961-07-19

    A proposal is made for a continuing ophthalmology program for exposed and control subjects at Nagasaki and Hiroshima. This program is based on a fixed population selected from the PE-86 and the ME-200 Adult Health Study samples. 27 references, 4 tables.

  9. Teaching and Assessing Systems-based Competency in Ophthalmology Residency Training Programs

    NARCIS (Netherlands)

    Lee, Andrew G.; Beaver, Hilary A.; Greenlee, Emily; Oetting, Thomas A.; Boldt, H. Culver; Olson, Richard; Abramoff, Michael; Carter, Keith

    2007-01-01

    The Accreditation Council for Graduate Medical Education (ACGME) has mandated that residency programs, including ophthalmology, teach and assess specific competencies, including systems-based learning. We review the pertinent literature on systems-based learning for ophthalmology and recommend

  10. Recent developments in diagnostic imaging techniques and management for acute pulmonary embolism. Multicenter registry by the Japanese Society of Pulmonary Embolism Research

    International Nuclear Information System (INIS)

    Sakuma, Masahito; Okada, Osamu; Nakamura, Mashio

    2003-01-01

    There are many reports on the diagnosis and management of acute pulmonary embolism (APE), but there have been no investigations concerning the actual conditions in which recent developments in diagnostic imaging techniques and therapies have been applied in clinical practice. The present study was designed to investigate the changes in diagnostic imaging techniques and therapies for APE. Three hundred and nine APE patients diagnosed during January 1994-October 1997 (Group 1) were compared with 257 APE patients diagnosed during November 1997-October 2000 (Group 2) in terms of the diagnostic imaging techniques and therapies for APE. Compared with Group 1, pulmonary angiography and contrast-enhanced computed tomography were more frequently performed for diagnosis in Group 2 [45.3% vs 56.8% (p=0.0069) and 13.9% vs 57.6% (p<0.0001), respectively]. Heparin and vena cava filter were used more often in Group 2 [74.4% vs 82.1% (p=0.033) and 18.4% vs 33.9% (p<0.0001), respectively]. The frequency of thrombolytic therapy was unchanged between the two groups. Warfarin use in discharged patients increased from 71.9% to 83.8% (p=0.0022). However, the examination rates for deep vein thrombosis (DVT) were low (60.8% in Group 1 and 65.4% in Group 2, p=0.29) and unchanged using any imaging techniques. The diagnostic imaging techniques for APE increased in variety and the management has improved, while the diagnosis for DVT remains unchanged. (author)

  11. [Establishment of diagnosis and treatment patterns of holistic integrated medicine for neuro-ophthalmology].

    Science.gov (United States)

    Wang, Yanling

    2014-12-01

    Neuro-ophthalmology, as an interdisciplinary, covers at least three disciplines- ophthalmology, neurology and neurosurgery. With limited knowledge in each discipline, doctors often make misdiagnoses for neuro-ophthalmology diseases. Therefore, it is imperative to abandon the distinction between disciplines and combine all the knowledge to diagnose and treat patients in patterns of holistic integrated medicine in order to effectively improve the diagnosis and treatment of neuro-ophthalmology.

  12. HINT for Squint: A Computer Reliant Diagnostic Aid for Strabismus

    OpenAIRE

    Gieszl, Louis R.; Morris, Jacqueline; Guyton, David L.

    1983-01-01

    This paper provides an outline of methods used for the implementation of a computer reliant diagnostic aid in the medical specialty of Ophthalmology. Some problems have been associated with many previous diagnostic models. A careful review indicates that the most serious problems were:

  13. Effects of optical diagnostic techniques on the accuracy of laminar flame speeds measured from Bunsen flames: OH* chemiluminescence, OH-PLIF and acetone/kerosene-PLIF

    Science.gov (United States)

    Wu, Yi; Modica, Vincent; Yu, Xilong; Li, Fei; Grisch, Frédéric

    2018-01-01

    The effects of optical diagnostic techniques on the accuracy of laminar flame speed measured from Bunsen flames were investigated. Laminar flame speed measurements were conducted for different fuel/air mixtures including CH4/air, acetone/air and kerosene (Jet A-1)/air in applying different optical diagnostic techniques, i.e. OH* chemiluminescence, OH-PLIF and acetone/kerosene-PLIF. It is found that the OH* chemiluminescence imaging technique cannot directly derive the location of the outer edge of the fresh gases and it is necessary to correct the position of the OH* peak to guarantee the accuracy of the measurements. OH-PLIF and acetone/kerosene-PLIF respectively are able to measure the disappearance of the fresh gas contour and the appearance of the reaction zone. It shows that the aromatic-PLIF technique gives similar laminar flame speed values when compared with those obtained from corrected OH* chemiluminescence images. However, discrepancies were observed between the OH-PLIF and the aromatic-PLIF techniques, in that OH-PLIF slightly underestimates laminar flame speeds by up to 5%. The difference between the flame contours obtained from different optical techniques are further analysed and illustrated with 1D flame structure simulation using detailed kinetic mechanisms.

  14. A general purpose diagnostic technique for marine diesel engines - Application on the main propulsion and auxiliary diesel units of a marine vessel

    International Nuclear Information System (INIS)

    Lamaris, V.T.; Hountalas, D.T.

    2010-01-01

    Diesel engines are widely used in marine applications (i.e. propulsion and auxiliaries) except from a few cases where gas or steam turbines are used. This is the result of their high efficiency, power concentration and reliability compared to other compatible or alternative power sources. The proper and efficient operation of the engines (main engine and diesel generator units) in marine applications is critical, and therefore techniques or systems that determine engine current condition and detect potential faults are extremely important. Furthermore, it is advantageous when such techniques can be applied on different engine configurations and provide reliable results, because on a vessel usually exist diesel engines of different type, i.e. the main propulsion unit is a large low-speed two-stroke diesel engine while the diesel generators are four-stroke medium or high speed engines. In the present work is described and evaluated for the first time the application of an improved diagnostic technique, developed by the authors, on both the main engine and the auxiliary units of a commercial marine vessel. The diagnostic technique is based on a thermodynamic simulation model. The simulation model embedded in the technique has been modified, namely an existing two-zone model is replaced by a multi-zone one. With this modification it is avoided model constant tuning with the operating conditions. This is extremely important for the diagnostic philosophy of the proposed technique. Using data from engine shop tests, the simulation model is calibrated (i.e. model constants are determined) and the engine reference condition is obtained. The simulation model is then used to estimate the current engine condition, using field measurements (i.e. cylinder pressure measurements, periphery data, etc.). From the results it is revealed that the diagnosis method provides detailed information for the operating condition of both engines and the values of parameters that cannot be

  15. The detection of lumpy skin disease virus in samples of experimentally infected cattle using different diagnostic techniques

    Directory of Open Access Journals (Sweden)

    E.S.M. Tuppurainen

    2005-09-01

    Full Text Available Lumpy skin disease (LSD is a disease of cattle, primarily in Africa and Madagascar and rarely in the Middle East. It is caused by a capripoxvirus that belongs to the family Poxviridae. The disease is of economic importance in endemic areas. Effective control of LSD requires accurate and rapid laboratory techniques to confirm a tentative clinical diagnosis. Comparative studies on different diagnostic tests used at different stages of the disease have not been done. The aim of this study was to compare several of these tests. Six seronegative bulls, between 11 and 20 months of age, were infected intravenously and kept in an insect-free facility. The course of the infection was monitored. During a 3-month period blood samples and skin biopsies were collected for virus isolation and polymerase chain reaction (PCR. Skin biopsies were also examined using transmission electron microscopy (TEM. The incubation period in infected animals varied from 4-5 days. The length of the viraemic period did not correlate with the severity of clinical disease. Viraemia was detected from 1-12 days using virus isolation and from 4-11 days using the PCR, which is longer than has previously been reported. Virus was isolated from skin biopsies until Day 39 post infection (p.i. and PCR could demonstrate viral DNA until Day 92 p.i. Transmission electron microscopy of negatively stained skin biopsies detected LSD virus only in one of the four bulls that developed skin lesions until Day 33 p.i. The PCR was a fast and sensitive method to demonstrate viral DNA in blood and skin samples. It could detect viral nucleic acid in skin lesions 53 days longer than virus isolation. Virus isolation from blood and skin samples was sensitive and reliable, but as a single test it may be too time-consuming to use although this depends on how rapidly the diagnosis must be confirmed. In conclusion, this study showed the PCR to be superior in detecting LSD virus from blood and skin samples

  16. Use of RT-PCR and elisa techniques for the diagnostic of infectious bronchitis virus in broilers at slaughter

    Directory of Open Access Journals (Sweden)

    Davi de Oliveira Almeida

    2015-03-01

    Full Text Available ABSTRACT. Almeida D.O., Tortely R., Nascimento E.R., Khan M., Pereira V.L.A & Babapoor S. [Use of RT-PCR and elisa techniques for the diagnostic of infectious bronchitis virus in broilers at slaughter.] Uso das técnicas de RT-PCR e elisa no diagnóstico da bronquite infecciosa em frangos de corte ao abate. Revista Brasileira de Medicina Veterinária, 37(1:55-59, 2015. Departamento de Saúde Coletiva Veterinária e Saúde Pública, Universidade Federal Fluminense, Rua Vital Brazil Filho, 64, Santa Rosa, Niterói, RJ 24230-340, Brasil. E-mail: elmiro@vm.uff.br Avian infectious bronchitis (IB is a viral, acute and highly contagious disease caused by infectious bronchitis virus (IBV. The disease affects broilers improvement and performance causing major economic losses in the world poultry industry. Generally, IBV infections can be diagnosed by detection of IBV itself or the specific antibody response. This study aimed to detect IBV in broilers under Sanitary Inspection by RT-PCR and ELISA, comparing the results and relating them with the average weight of the flock. Samples were collected from 40 vaccinated broiler flocks under Sanitary Inspection at slaughter. Ten birds from every flock were randomly selected and blood samples were collected for ELISA as well three birds had their trachea and caecal tonsils collected for RT- -PCR test. From 40 flocks, 30 were IBV positive by ELISA and 26 by RT-PCR, in which 15 were detected simultaneously in trachea and caecal tonsil and 5 in each sample. There was no agreement between ELISA and RT-PCR results regarding IBV diagnosis as well positivity in both tests was not statistically significant with the average weight of the flock. There was an improvement on IBV diagnosis when caecal tonsils and tracheas were used instead of just one of them. Considering the only vaccine serotype allowed by Brazilian government is the Mass serotype and its persistence in broilers would only be detected up to 28 days

  17. Vincenz Fukala (1847-1911): versatile surgeon and early historian of ophthalmology.

    Science.gov (United States)

    Schmidt, Dieter; Grzybowski, Andrzej

    2011-01-01

    Vincenz Fukala is best known for his technique of discission and linear extraction of the lens in young, highly myopic eyes--the technique adopted by Harold Ridley in preparation for lens implantation in young patients. He was Polish and trained in Vienna under Karl Ferdinand. von Arlt. Fukala practiced first in Pilsen (1889-1894), but returned to Vienna in 1895. He studied trachoma in Egypt in 1872. His research on scrofulous eye disease led him twice to the United States, in 1891 and 1892. Fukala also developed highly successful, pioneering techniques for the treatment of ectropion in blepharitis, of trachoma, and of shallow sockets following enucleation. In glaucoma, he recommended early iridectomy of the fellow eye when the first eye has gone blind. He was also an expert on the history of ancient European texts and of Arabic ophthalmology. Copyright © 2011 Elsevier Inc. All rights reserved.

  18. RESULTS OF THE SURVEY CONDUCTED AMONG OPHTHALMOLOGISTS ON THE ISSUE OF EQUIPMENT OF MEDICAL INSTITUTIONS WITH OPHTHALMOLOGY DEVICES

    Directory of Open Access Journals (Sweden)

    S. V. Seraphimov

    2017-01-01

    Full Text Available Introduction. The problem of limited accessibility and quality of ophthalmic medical care remains one of the leading ones in the national healthcare. This article presents results of the survey conducted among ophthalmologists about the effect of large-scale equipment of all medical institutions in the Leningrad Region with modern ophthalmologic devices over the recent years.Objective is to determine the contribution of the health care modernization program to equipping the medical institutions of the Leningrad Region with modern ophthalmologic medical devices, and to identify the main areas for improving the ophthalmologic care for residents of the Leningrad region with cataracts.Materials and methods. According to a specially developed questionnaire, 105 ophthalmologists from the Leningrad Region were interviewed. The survey was conducted among physicians working both in out-patient medical facilities and in medical facilities with in-patient modalities.Results. The results of the study confirmed positive changes that occurred in recent years as a result of equipping medical institutions with modern medical devices. Almost two-thirds (59.9% of respondents noted that equipping with modern medical devices had a significant impact on the quality of the medical and diagnostic measures carried out in healthcare facilities of the region.Conclusions. The equipment had a significant impact on the diagnosis and treatment of all kinds of diseases of the eye and its appendages, especially such eye disease which is so common among the population of the Leningrad Region as cataracts (75.0 per 100 ophthalmologists surveyed. At the same time, in spite of these efforts, the standard for equipping ophthalmologic departments in individual medical institutions has not been fully provided. Only every fifth (20.9% ophthalmologist noted during the survey that the list of available ophthalmic devices was sufficient, and that they all worked properly.

  19. Science for ophthalmology: The Miracle Mission

    International Nuclear Information System (INIS)

    Munniz Planas, G.; Castellanos Garces, A.

    2008-01-01

    Full text: The 'Miracle' is an important task of solidarity through which more than one million poor people in different parts of the world have recovered their sight. This work, on the thread a cataract operation, discloses the presence of physics as a science in the equipment used to carry it out. Since the use of ultrasound to calculate the intraocular lens to replace the diseased lens, the use of mechanical oscillations at ultrasonic frequencies for emulsifying and removing it from its capsule by phacoemulsification, until the removal of opacities of the capsule in secondary cataracts and other treatments in diseases of the retina from diabetes, glaucoma or laser aging techniques. It includes a description of systems with excimer laser refractive surgery to correct myopia, hyperopia, astigmatism and other combinations of these ocular optical system conditions. Actual operations will be shown that these processes are observed. It also describes the operation of an optical coherence tomography for retina studies highlighting its operating principle the presence of coherent optical and interferometric techniques. Ends with the description of the graduate system conceived in the Higher Polytechnic Institute 'Jose Antonio Echeverria' (ISPJAE) with participation of specialists in optics and laser across the country for training personnel to ensure the installation, maintenance and repair of all this equipment

  20. Diagnostic performance of state-of-the-art imaging techniques for morphological assessment of vascular abnormalities in patients with chronic thromboembolic pulmonary hypertension (CTEPH)

    Energy Technology Data Exchange (ETDEWEB)

    Ley, Sebastian [University Hospital Heidelberg, Department of Diagnostic and Interventional Radiology, Heidelberg (Germany); Ley-Zaporozhan, Julia [University Hospital Heidelberg, Department of Diagnostic and Interventional Radiology, Heidelberg (Germany); Johannes Gutenberg University, Department of Diagnostic and Interventional Radiology; Universitaetsmedizin, Mainz (Germany); Pitton, Michael B.; Schneider, Jens; Wirth, Gesine M.; Dueber, Christoph; Kreitner, Karl-Friedrich [Johannes Gutenberg University, Department of Diagnostic and Interventional Radiology; Universitaetsmedizin, Mainz (Germany); Mayer, Eckhard [Kerckhoff-Hospital Bad Nauheim, Department of Thoracic Surgery, Bad Nauheim (Germany)

    2012-03-15

    To determine the most comprehensive imaging technique for the assessment of pulmonary arteries in patients with chronic thromboembolic pulmonary hypertension (CTEPH). 24 patients with CTEPH were examined by ECG-gated multi-detector CT angiography (MD-CTA), contrast-enhanced MR angiography (ce-MRA) and selective digital subtraction angiography (DSA) within 3 days. Two readers in consensus separately evaluated each imaging technique (48 main, 144 lobar and 449 segmental arteries) for typical changes like complete obstructions, vessel cut-offs, intimal irregularities, incorporated thrombus formations, and bands and webs. A joint interpretation of all three techniques served as a reference standard. Based on image quality, there was no non-diagnostic examination by either imaging technique. DSA did not sufficiently display 1 main, 3 lobar and 4 segmental arteries. The pulmonary trunk was not assessable by DSA. One patient showed thrombotic material at this level only by MD-CTA and MRA. Sensitivity and specificity of MD-CTA regarding CTEPH-related changes at the main/lobar and at the segmental levels were 100%/100% and 100%/99%, of ce-MRA 83.1%/98.6% and 87.7%/98.1%, and of DSA 65.7%/100% and 75.8%/100%, respectively. ECG-gated MD-CTA proved the most adequate technique for assessment of the pulmonary arteries in the diagnostic work-up of CTEPH patients. (orig.)

  1. Assessment of online patient education materials from major ophthalmologic associations.

    Science.gov (United States)

    Huang, Grace; Fang, Christina H; Agarwal, Nitin; Bhagat, Neelakshi; Eloy, Jean Anderson; Langer, Paul D

    2015-04-01

    Patients are increasingly using the Internet to supplement finding medical information, which can be complex and requires a high level of reading comprehension. Online ophthalmologic materials from major ophthalmologic associations should be written at an appropriate reading level. To assess ophthalmologic online patient education materials (PEMs) on ophthalmologic association websites and to determine whether they are above the reading level recommended by the American Medical Association and National Institutes of Health. Descriptive and correlational design. Patient education materials from major ophthalmology websites were downloaded from June 1, 2014, through June 30, 2014, and assessed for level of readability using 10 scales. The Flesch Reading Ease test, Flesch-Kincaid Grade Level, Simple Measure of Gobbledygook test, Coleman-Liau Index, Gunning Fog Index, New Fog Count, New Dale-Chall Readability Formula, FORCAST scale, Raygor Readability Estimate Graph, and Fry Readability Graph were used. Text from each article was pasted into Microsoft Word and analyzed using the software Readability Studio professional edition version 2012.1 for Windows. Flesch Reading Ease score, Flesch-Kincaid Grade Level, Simple Measure of Gobbledygook grade, Coleman-Liau Index score, Gunning Fog Index score, New Fog Count, New Dale-Chall Readability Formula score, FORCAST score, Raygor Readability Estimate Graph score, and Fry Readability Graph score. Three hundred thirty-nine online PEMs were assessed. The mean Flesch Reading Ease score was 40.7 (range, 17.0-51.0), which correlates with a difficult level of reading. The mean readability grade levels ranged as follows: 10.4 to 12.6 for the Flesch-Kincaid Grade Level; 12.9 to 17.7 for the Simple Measure of Gobbledygook test; 11.4 to 15.8 for the Coleman-Liau Index; 12.4 to 18.7 for the Gunning Fog Index; 8.2 to 16.0 for the New Fog Count; 11.2 to 16.0 for the New Dale-Chall Readability Formula; 10.9 to 12.5 for the FORCAST scale; 11

  2. Optimized design of shields for diagnostic X rays with NCRP 147 technique; Diseno optimizado de blindajes para rayos X diagnostico con tecnica NCRP 147

    Energy Technology Data Exchange (ETDEWEB)

    Gama T, G. [Calidad XXI SA de CV, Zacatecas 67-007 Col. Roma, 06700 Mexico D.F. (Mexico)]. e-mail: cxxi@prodigy.net.mx

    2006-07-01

    A comparison among the design techniques of shielding for X-ray diagnostic rooms with the NCRP 49 (1976) report technique, AAPM 39 (1993) Y the one of the NCRP 147 (2005) technique. The designs correspond to a room of conventional X-rays, one of fluoroscopy, one of tomography Y one of mammography. In all the cases it demonstrates that the NCRP 49 technique overestimate the shieldings. The causes of the overestimation of the NCRP 49 can be attributed to: a) high values of the work charge that don't consider the spectral fluence of the photons that are present in each room, b) to the differences in the values of the kerma in air without attenuation for the dispersed primary radiation Y of leakage among both reports. (Author)

  3. [To strengthen the education on basic knowledge and skills of neuro-ophthalmology].

    Science.gov (United States)

    Zhang, Xiao-jun; Wang, Ning-li

    2011-12-01

    Basic knowledge and skills are cornerstone of the diagnosis and treatment of neuro-ophthalmology diseases in ophthalmology practice. Due to the interdisciplinary features of neuro-ophthalmology, neuro-anatomy, neuro-physiology related to eyes, neuro-image and neuro-electrodiagnosis, these should be included in the education for the ophthalmologist. Special attention should be paid to training on capability of logically thinking in neuro-ophthalmology. Multiple ways can be used for the education of ophthalmologists and neurologists for the enhancement of basic knowledge and skills of neuro-ophthalmology in China.

  4. Quasi-Elastic Light Scattering in Ophthalmology

    Science.gov (United States)

    Ansari, Rafat R.

    The eye is not just a "window to the soul"; it can also be a "window to the human body." The eye is built like a camera. Light which travels from the cornea to the retina traverses through tissues that are representative of nearly every tissue type and fluid type in the human body. Therefore, it is possible to diagnose ocular and systemic diseases through the eye. Quasi-elastic light scattering (QELS) also known as dynamic light scattering (DLS) is a laboratory technique routinely used in the characterization of macromolecular dispersions. QELS instrumentation has now become more compact, sensitive, flexible, and easy to use. These developments have made QELS/DLS an important tool in ophthalmic research where disease can be detected early and noninvasively before the clinical symptoms appear.

  5. Myocardial tagging with steady state free precession techniques and semi-automatic postprocessing--impact on diagnostic value

    DEFF Research Database (Denmark)

    Johnson, Thorsten R C; Bayrhof, Nicole; Huber, Armin

    2007-01-01

    Our aim was to determine the diagnostic value of myocardial tagging sequences with regard to the evaluable share of the cardiac cycle. Thirty-three patients were examined at 1.5 T using tagging sequences with gradient-echo (GRE) readout, 18 patients at 1.5 T with steady-state free precession (SSF...

  6. A pilot study using laser-based technique for non-invasive diagnostics of hypertensive conditions in mice

    Science.gov (United States)

    Litvinova, Karina S.; Ahmad, Shakil; Wang, Keqing; Rafailov, Ilya E.; Sokolovski, Sergei G.; Zhang, Lin; Rafailov, Edik U.; Ahmed, Asif

    2016-02-01

    Endothelial dysfunction is directly linked to preeclampsia, a maternal hypertensive condition that is life threating for both the mother and the baby. Epidemiological studies show that women with a history of pre-eclampsia have an elevated risk for cardiovascular disease. Here we report a new non-invasive diagnostic test for preeclampsia in mice that allows us to non-invasively assess the condition of the animals during the experiment and treatment in established models of preeclampsia. A laser-based multifunctional diagnostics system (LAKK-M) was chosen to carry out non-invasive analysis of multiple parameters. The device was used to simultaneously record the microcirculatory blood flow and oxygen saturation, as well as fluorescence levels of endogenous fluorophores. Preliminary experiments were conducted on adenoviral (Ad-)- mediated overexpression of sFlt-1 (Ad-sFlt-1) to mimic preeclampsialike symptoms in mice. The recorded data displayed the ability of the LAKK-M diagnostics device to detect significant differences in perfusion measurements between the control and Ad-sFlt-1 treatment. Preliminary results provide a potential avenue to employ these diagnostics technology to monitor and aid in maintaining control of live animal conditions throughout the experiment and treatment.

  7. The Global Education Network for Retinopathy of Prematurity (Gen-Rop): Development, Implementation, and Evaluation of A Novel Tele-Education System (An American Ophthalmological Society Thesis)

    Science.gov (United States)

    Chan, R.V. Paul; Patel, Samir N.; Ryan, Michael C.; Jonas, Karyn E.; Ostmo, Susan; Port, Alexander D.; Sun, Grace I.; Lauer, Andreas K.; Chiang, Michael F.

    2015-01-01

    Purpose: To describe the design, implementation, and evaluation of a tele-education system developed to improve diagnostic competency in retinopathy of prematurity (ROP) by ophthalmology residents. Methods: A secure Web-based tele-education system was developed utilizing a repository of over 2,500 unique image sets of ROP. For each image set used in the system, a reference standard ROP diagnosis was established. Performance by ophthalmology residents (postgraduate years 2 to 4) from the United States and Canada in taking the ROP tele-education program was prospectively evaluated. Residents were presented with image-based clinical cases of ROP during a pretest, posttest, and training chapters. Accuracy and reliability of ROP diagnosis (eg, plus disease, zone, stage, category) were determined using sensitivity, specificity, and the kappa statistic calculations of the results from the pretest and posttest. Results: Fifty-five ophthalmology residents were provided access to the ROP tele-education program. Thirty-one ophthalmology residents completed the program. When all training levels were analyzed together, a statistically significant increase was observed in sensitivity for the diagnosis of plus disease, zone, stage, category, and aggressive posterior ROP (P<.05). Statistically significant changes in specificity for identification of stage 2 or worse (P=.027) and pre-plus (P=.028) were observed. Conclusions: A tele-education system for ROP education is effective in improving diagnostic accuracy of ROP by ophthalmology residents. This system may have utility in the setting of both healthcare and medical education reform by creating a validated method to certify telemedicine providers and educate the next generation of ophthalmologists. PMID:26538772

  8. Value of five noninvasive diagnostic techniques and their combinations in diagnosis of liver fibrosis in patients with chronic hepatitis B

    Directory of Open Access Journals (Sweden)

    ZHANG Xu

    2016-10-01

    Full Text Available Objective To investigate the correlation of aspartate aminotransferase to platelet ratio index (APRI, FIB-4, Forns index, S index, and FibroScan with the degree of liver fibrosis, the diagnostic value of these techniques used alone or in combination, and the clinical value of these noninvasive techniques in the assessment of the degree of liver fibrosis in patients with chronic hepatitis B (CHB. Methods A retrospective analysis was performed for the clinical data of 91 patients with pathologically confirmed CHB who visited General Hospital of Ningxia Medical University and underwent liver biopsy from January 2009 to April 2015. According to the Scheuer pathological stage and liver fibrosis stage (S, the patients were divided into non-liver fibrosis group (a liver fibrosis stage of S0, 32 patients, mild liver fibrosis group (a liver fibrosis stage of <S2, 30 patients, and marked liver fibrosis group (a liver fibrosis stage of ≥S2, 29 patients. The APRI, FIB-4, Forns index, and S index were calculated, and liver stiffness was measured by FibroScan. An analysis of variance was used for the comparison of normally distributed continuous data between three groups, and the Dunnett t-test was used for further comparison between any two groups. The Spearman correlation analysis was also performed. Sensitivity, specificity, and area under the receiver operating characteristic curve (AUC were used to evaluate the value of these noninvasive techniques in the diagnosis of liver fibrosis. Results There were significant differences in age, albumin, aspartate aminotransferase, alanine aminotransferase, and platelet count between the three groups (F=3.552, 4.035, 4.374, and 5.992, all P<0.05, and there were significant differences in these parameters between the non-liver fibrosis group and the mild and marked liver fibrosis groups (P<0.05. There were significant differences in APRI, FIB-4, Forns index, S index, and FibroScan between the three groups (F

  9. Teaching of ophthalmology in undergraduate curricula: a survey of Australasian and Asian medical schools.

    Science.gov (United States)

    Fan, Jennifer C; Sherwin, Trevor; McGhee, Charles N J

    2007-01-01

    Despite established international guidelines on preferred teaching components for ophthalmology in undergraduate curricula, with increasingly less specialty-based undergraduate teaching within curricula, teaching of core ophthalmology knowledge and skills may become marginalized. This survey aims to evaluate the current state of undergraduate ophthalmology teaching in Australasia and proximate Asian medical schools. A questionnaire was developed to determine the content and extent of ophthalmology teaching in the undergraduate medical curriculum. The questionnaire was sent to 25 medical schools throughout Australasia and Asia. Nineteen of the 25 questionnaires were returned (76% response rate). Ophthalmology teaching programmes ranged from 2 to 20 days: five (26%) medical schools having one ophthalmology attachment; six schools (32%) two attachments; and the remainder three or more. Only seven of the schools taught all 13 ophthalmology topics recommended in current curriculum guidelines. Ocular examination (100%), lens and cataract (95%) and ocular manifestations of systemic disease (95%) were the most commonly taught topics, with intraocular tumours only covered by 10 schools (53%). Students in 14 schools (74%) attended ophthalmology operating theatre, but only two schools (11%) offered attendance at optometry clinics. Ten schools (53%) required a pass in ophthalmology to complete the academic year. Ophthalmology may increasingly be a small, or even absent, component of undergraduate medical curricula. Despite established international ophthalmology curriculum guidelines, this survey highlights significant lack of uniformity in their implementation.

  10. Comparison of exercise perfusion and ventricular function imaging: an analysis of factors affecting the diagnostic accuracy of each technique

    International Nuclear Information System (INIS)

    Osbakken, M.D.; Okada, R.D.; Boucher, C.A.; Strauss, H.W.; Pohost, G.M.

    1984-01-01

    Exercise thallium-201 perfusion scans and gated equilibrium blood pool scans were performed in 120 catheterized patients with a chest pain syndrome. Eighty-six patients had coronary artery disease and 34 patients did not. The effects of gender, propranolol, exercise level, exercise ischemia, history of typical angina, history of previous myocardial infarction, electrocardiographic Q waves, number of diseases vessels and extent of coronary artery obstruction on diagnostic accuracy were evaluated. Thallium scans and anginal history were less sensitive for detecting coronary disease in women (men: thallium 79%; angina 77%; women: 54 and 46%, respectively; p less than 0.05). Exercise level did not significantly affect the diagnostic accuracy of either scan. Thallium and gated scans were both highly sensitive (95%) in detecting disease in 20 patients with a prior myocardial infarction, angina and a positive electrocardiogram. The sensitivity of the thallium scan significantly decreased as the number of diseased vessels decreased. Both thallium and gated scans were less frequently positive in patients with atypical angina or no Q waves, but were not significantly influenced by electrocardiographic ischemia. The sensitivity and specificity of both scans were low in 57 patients with the combination of atypical angina, no history of infarction and equivocal stress electrocardiogram thallium. When stress thallium scan evaluation included the electrocardiogram and thallium scan interpretation, the diagnostic accuracy was 81%. When all the information from gated scans (wall motion, ejection fraction, pulmonary blood volume) was combined for final gated scan evaluation, the diagnostic accuracy was 83%. When electrocardiographic data were added to all three gated scan variables, diagnostic accuracy was 77%

  11. Models for joint ophthalmology-optometry patient management.

    Science.gov (United States)

    Kim, John J; Kim, Christine M

    2011-07-01

    American Academy of Ophthalmology (AAO) and American Society of Cataract and Refractive Surgery (ASCRS) presented a joint position paper in February 2000 declaring that they do not support routine comanagement of patients with the optometrists. American Optometric Association and American Academy of Optometry quickly responded in support of AAO and ASCRS. All four entities did not preclude legitimate and proper comanagement arrangements. Since that time, the pattern of practice has changed, requiring us to rethink our positions. This paper is written to provide a possible model for the ophthalmology-optometry practice management in ophthalmic surgeries including refractive surgery. Since the publication of the Joint Position Paper, the concept of comanagement has faded and a new model of integrated management has evolved. This has occurred as the changes in the employment pattern of the ophthalmic practice have incorporated optometrists into its fold. This evolution allowed ophthalmic and optometric community to co-exist and thrive to provide better patient care.

  12. [Essential aspects of ophthalmological expert assessment in private accident insurance].

    Science.gov (United States)

    Tost, F

    2014-06-01

    Commissions for an expert assessment place basically high demands on commissioned eye specialists because this activity differs from the normal routine field of work. In addition to assessing objective symptoms and subjective symptomatics in a special analytical manner, eye specialists are expected to have knowledge of basic legal terminology, such as proximate cause, evidence and evidential value. Only under these prerequisites can an ophthalmologist fulfill the function of an expert with a high level of quality and adequately adjust the special medical ophthalmological expertise to the requirements of the predominantly legally based clients commissioning the report and oriented to the appropriate valid legal norms. Particularly common difficulties associated with making an ophthalmological expert report for private accident insurance, e.g. determination of the reduction in functional quality, consideration of partial causality and assessment of diplopia are discussed.

  13. [Teleconsultation network for ophthalmology--experiences and results].

    Science.gov (United States)

    Zahlmann, G; Walther, H D; Liesenfeld, B; Kaatz, H; Kluthe, S; Fabian, E; Klaas, D; Schnarr, K D; Neubauer, L; Obermaier, M; Wegner, A; Mertz, M; Mann, G

    1998-02-01

    Telemedical services for ophthalmology are developed within the OPHTEL project, which has been funded by the European Union and by the Bavarian government in the Bavaria-online initiative. Seven private ophthalmologists, one university eye clinic, one clinical Diabetes center and an informatics research institute are connected within a teleconsultation network. Asynchronous (based on Internet E-Mail) and synchronous (based on ISDN-mediated videoconferencing tools) types of teleconsultations are realized. 86 teleconsultations (62 asynchronous, 23 synchronous) took place within the first 10 months. Complex and rare eye diseases as well as interdisciplinary questions (ophthalmology--diabetology) are the main area of medical communication interest. Legal and security problems are discussed. Telemedical services must be understood as a complete process of medical care on the basis of modern communication technologies, which influences also the management of this process.

  14. Novel use of smart tablet computer for ophthalmology

    Directory of Open Access Journals (Sweden)

    Zhao-Tian Zhang

    2015-01-01

    Full Text Available AIM:To identify and categorize ophthalmology-relevant apps for the iPad tablet computer as a source for ophthalmic practices on the Apple's App Store.METHODS: The Apple's App Store was searched for ophthalmology-relevant apps from January 2013 to August 2013. Eligible apps were identified and downloaded into the iPad tablet computers, and then categorized according to the apps' initial contents and our using experiences. Methods about how to use the iPad's built-in functions of instant video call(FaceTime®and automatic data storage technology(iCloud®were also described together with the apps. Other operating systems of Microsoft's Window Phone and Google's Android were also searched for ophthalmology-relevant apps.RESULTS: The keywords for searching on the Apple's App Store were “ophthalmology” and “eye”. And we could found 111 eligible apps with the former keyword, and 452 ones with the latter one. The integrated uses of the iPad tablet computer were then categorized into five aspects. Based on our clinical practice, we finally summarized the advantages and disadvantages of the iPad tablet computer for ophthalmic practices. However, ophthalmology-relevant apps were found to be very limited in number on the other two platforms.CONCLUSION: The integrated use of self built-in apps and third-party apps can facilitate our clinical work in examination, telemedicine, reference, disease education and literature searching. More studies are needed to verify its validation and reliability in the professional fields, especially eye examinations.

  15. Clinical safety and professional liability claims in Ophthalmology.

    Science.gov (United States)

    Dolz-Güerri, F; Gómez-Durán, E L; Martínez-Palmer, A; Castilla Céspedes, M; Arimany-Manso, J

    2017-11-01

    Patient safety is an international public health priority. Ophthalmology scientific societies and organisations have intensified their efforts in this field. As a tool to learn from errors, these efforts have been linked to the management of medical professional liability insurance through the analysis of claims. A review is performed on the improvements in patient safety, as well as professional liability issues in Ophthalmology. There is a high frequency of claims and risk of economic reparation of damage in the event of a claim in Ophthalmology. Special complaints, such as wrong surgery or lack of information, have a high risk of financial compensation and need strong efforts to prevent these potentially avoidable events. Studies focused on pathologies or specific procedures provide information of special interest to sub-specialists. The specialist in Ophthalmology, like any other doctor, is subject to the current legal provisions and appropriate mandatory training in the medical-legal aspects of health care is essential. Professionals must be aware of the fundamental aspects of medical professional liability, as well as specific aspects, such as defensive medicine and clinical safety. The understanding of these medical-legal aspects in the routine clinical practice can help to pave the way towards a satisfactory and safe professional career, and help in increasing patient safety. The aim of this review is to contribute to this training, for the benefit of professionals and patients. Copyright © 2017 Sociedad Española de Oftalmología. Publicado por Elsevier España, S.L.U. All rights reserved.

  16. Toward computer-assisted diagnosis and telemedicine in ophthalmology

    Czech Academy of Sciences Publication Activity Database

    Marrugo, A.; Millán, M. S.; Cristóbal, G.; Gabarda, S.; Šorel, Michal; Šroubek, Filip

    2012-01-01

    Roč. 2012, č. 6 (2012), s. 1-3 ISSN 1818-2259 R&D Projects: GA MŠk 1M0572 Institutional research plan: CEZ:AV0Z10750506 Institutional support: RVO:67985556 Keywords : computer-aided diagnosis * medical and retinal image * deconvolution * telemedicine Subject RIV: JD - Computer Applications, Robotics http://library.utia.cas.cz/separaty/2012/ZOI/sorel-toward computer-assisted diagnosis and telemedicine in ophthalmology.pdf

  17. [International relationships in ophthalmology in the German Democratic Republic (GDR)].

    Science.gov (United States)

    Jähne, M

    2017-09-01

    International relationships in ophthalmology in the former German Democratic Republic (GDR) were directed by the government and predominantly promoted relationships to socialist countries in Eastern Europe. The lack of freedom of travel, restrictions of import for scientific journals and general prevention of contacts by the State security service led to a stagnation in daily practice and in research, mainly from 1961 until 1989.

  18. The human resource crisis in neuro-ophthalmology.

    Science.gov (United States)

    Frohman, Larry P

    2008-09-01

    Neuro-ophthalmology is facing a serious human resource issue. Few are entering the subspecialty, which is perceived as being poorly compensated compared with other subspecialties of ophthalmology. The low compensation comes from the fact that 1) non-procedural encounters remain undervalued, 2) efforts that benefit other medical specialists are not counted, and 3) the relatively low expenses of neuro-ophthalmologists are not factored into compensation formulas. Mission-based budgeting, which forces academic departments to be financially accountable without the expectation of fiscal relief from medical schools or practice plans, has exacerbated the compensation issue. Solutions must come from within neuro-ophthalmology, academic departments, medical schools, and medical practice plans. They include 1) providing educational resources so that neuro-ophthalmologists need not spend so much time teaching the basics, 2) factoring into compensation the impact of neuro-ophthalmologists in teaching and on revenue generation by procedure-based specialists, 3) improving the efficiency of neuro-ophthalmologists in their consultative practices by providing ample clerical support and other measures, 4) providing contractual salary compensation by departments such as neurosurgery to recognize the contributions made by neuro-ophthalmologists, and 5) reorganizing the academic clinical effort as multidisciplinary rather than departmental.

  19. Alberto Urrets-Zavalía Jr (1920-2010): An Argentinian contributor to ophthalmology.

    Science.gov (United States)

    Grzybowski, Andrzej; Urrets-Zavalía, Julio A; Ascaso, Francisco J

    2016-05-01

    Alberto Urrets-Zavalía Jr was born in Córdoba (Argentina) in 1920. Chairman of the Department of Ophthalmology of the National University of Córdoba and founder of the Cornea and Glaucoma Surgical Center in the same city, in 1956 he created the first residency programme in Ophthalmology in his country. He founded the first Eye Bank and introduced one of the first argon laser photocoagulators in South America. He authored around 200 scientific presentations and publications, describing new findings and clinical entities. Thus, his individualisation of the cyclovertical component in strabismus contributed to important evolution of ideas concerning pathogenesis and therapy in oculomotor disorders of infancy. He was the first to propose the dehydration of the vitreous body in glaucoma patients before ocular surgery and developed a fixation pick and scleral depressor for retinal detachment surgery. He also described a new technique, the V-Z procedures for the correction of senile ectropion. In 1968, he published his Décollement de la rétine, considered a masterpiece in retinal detachment literature for many years. Urrets-Zavalía died in his native city at the age of 89. His prolific scientific and educational contributions make him one of the most brilliant and influential ophthalmologists of the 20th-century. © The Author(s) 2014.

  20. Assessment of Durability of Online and Multisensory Learning Using an Ophthalmology Model.

    Science.gov (United States)

    Lippa, Linda Mottow; Anderson, Craig L

    2015-10-01

    To explore the impact of online learning and multisensory small-group teaching on acquisition and retention of specialty knowledge and diagnostic skills during a third-year family medicine rotation. Exploratory, observational, longitudinal, and multiple-skill measures. Two medical school classes (n = 199) at a public medical school in California. Students engaged in online self-study, small-group interactive diagnostic sessions, picture identification of critical pathologic features, and funduscopic simulator examinations. The authors compared performance on testing immediately after online learning with testing at end-rotation, as well as picture identification versus simulator diagnostic ability in students with (n = 94) and without (n = 105) practice tracing contours on whiteboard projections of those same slides depicting fundus pathologic features of common systemic diseases. Picture identification, accuracy of funduscopic descriptions, online module post-tests, and end-rotation tests. Proprioceptive reinforcement of fundus pattern recognition significantly reduced the need for remediation for misdiagnosing optic disc edema during end-rotation funduscopic simulator testing, but it had no effect on fundus pattern recognition or diagnostic ability overall. Near-perfect immediate online post-test scores contrasted sharply with poor end-rotation scores on an in-house test (average, 59.4%). Rotation timing was not a factor because the patterns remained consistent throughout the academic school year. Neither multisensory teaching nor online self-study significantly improved retention of ophthalmic knowledge and diagnostic skills by the end of a month-long third-year rotation. Timing such training closer to internship when application is imminent may enhance students' appreciation for its value and perhaps may improve retention. Pulsed quizzes over time also may be necessary to motivate students to retain the knowledge gained. Copyright © 2015 American Academy of

  1. Modeling and diagnostic techniques applicable to the analysis of pressure noise in pressurized water reactors and pressure-sensing systems

    International Nuclear Information System (INIS)

    Mullens, J.A.; Thie, J.A.

    1984-01-01

    Pressure noise data from a PWR are interpreted by means of a computer-implemented model. The model's parameters, namely hydraulic impedances and noise sources, are either calculated or deduced from fits to data. Its accuracy is encouraging and raises the possibility of diagnostic assistance for nuclear plant monitoring. A number of specific applications of pressure noise in the primary system of a PWR and in a pressure sensing system are suggested

  2. Application of the denaturing gradient gel electrophoresis (DGGE) technique as an efficient diagnostic tool for ciliate communities in soil

    OpenAIRE

    Jousset, Alexandre; Lara, Enrique; Nikolausz, Marcell; Harms, Hauke; Chatzinotasa, Antonis

    2010-01-01

    Ciliates (or Ciliophora) are ubiquitous organisms which can be widely used as bioindicators in ecosystems exposed to anthropogenic and industrial influences. The evaluation of the environmental impact on soil ciliate communities with methods relying on morphology-based identification may be hampered by the large number of samples usually required for a statistically supported, reliable conclusion. Cultivation-independent molecular-biological diagnostic tools are a promising alternative to gre...

  3. Complex polarimetric and spectral techniques in diagnostics of blood plasma of patients with ovarian cancer as a preliminary stage molecular genetic screening

    Science.gov (United States)

    Grzegorzewski, B.; Peresunko, O. P.; Yermolenko, S. B.

    2018-01-01

    This work is devoted to the substantiation and selection of patients with ovarian cancer (OC) for the purpose of conducting expensive molecular genetic studies on genotyping. As diagnostic methods have been used ultraviolet spectrometry samples of blood plasma in the liquid state, infrared spectroscopy middle range (2,5 - 25 microns) dry residue of plasma polarization and laser diagnostic technique of thin histological sections of biological tissues. Obtained results showed that the use of spectrophotometry in the range of 1000-3000 cm-1 allowed to establish quantitative parameters of the plasma absorption rate of blood of patients in the third group in different ranges, which would allow in the future to conduct an express analysis of the patient's condition (procedure screening) for further molecular-genetic typing on BRCA I and II.

  4. Comparison of the Diagnostic Performance of Power Doppler Ultrasound and a New Microvascular Doppler Ultrasound Technique (AngioPLUS) for Differentiating Benign and Malignant Breast Masses.

    Science.gov (United States)

    Jung, Hae Kyoung; Park, Ah Young; Ko, Kyung Hee; Koh, Jieun

    2018-03-12

    This study was performed to compare the diagnostic performance of power Doppler ultrasound (US) and a new microvascular Doppler US technique (AngioPLUS; SuperSonic Imagine, Aix-en-Provence, France) for differentiating benign and malignant breast masses. Power Doppler US and AngioPLUS findings were available in 124 breast masses with confirmed pathologic results (benign, 80 [64.5%]; malignant, 44 [35.5%]). The diagnostic performance of each tool was calculated to distinguish benign from malignant masses using a receiver operating characteristic curve analysis and compared. The area under the curve showed that AngioPLUS was superior to power Doppler US in differentiating benign from malignant breast masses, but the difference was not statistically significant. © 2018 by the American Institute of Ultrasound in Medicine.

  5. Reliability of diagnostic imaging techniques in suspected acute appendicitis: proposed diagnostic protocol; Indicacion de las tecnicas de diagnostico por la imagen en la sospecha de apendicitis aguda: propuesta de protocolo diagnostico

    Energy Technology Data Exchange (ETDEWEB)

    Cura del, J. L.; Oleaga, L.; Grande, D.; Vela, A. C.; Ibanez, A. M. [Hospital de Basureto. Bilbao (Spain)

    2001-07-01

    To study the utility of ultrasound and computed tomography (CT) in case of suspected appendicitis. To determine the diagnostic yield in terms of different clinical contexts and patient characteristics. to assess the costs and benefits of introducing these techniques and propose a protocol for their use. Negative appendectomies, complications and length of hospital stay in a group of 152 patients with suspected appendicitis who underwent ultrasound and CT were compared with those of 180 patients who underwent appendectomy during the same time period, but had not been selected for the first group: these patients costs for each group were calculated. In the first group, the diagnostic value of the clinical signs was also evaluated. The reliability of the clinical signs was limited, while the results with ultrasound and CT were excellent. The incidence of negative appendectomy was 9.6% in the study group and 12.2% in the control group. Moreover, there were fewer complications and a shorter hospital stay in the first group. Among men, however, the rate of negative appendectomy was lower in the control group. The cost of using ultrasound and CT in the management of appendicitis was only slightly higher than that of the control group. Although ultrasound and CT are not necessary in cases in which the probability of appendicitis is low or in men presenting clear clinical evidence, the use of these techniques is indicated in the remaining cases in which appendicitis is suspected. In children, ultrasound is the technique of choice. In all other patients, if negative results are obtained with one of the two techniques, the other should be performed. (Author) 49 refs.

  6. Diagnostic Accuracy of Imaging Modalities and Injection Techniques for the Diagnosis of Femoroacetabular Impingement/Labral Tear: A Systematic Review With Meta-analysis.

    Science.gov (United States)

    Reiman, Michael P; Thorborg, Kristian; Goode, Adam P; Cook, Chad E; Weir, Adam; Hölmich, Per

    2017-09-01

    Diagnosing femoroacetabular impingement/acetabular labral tear (FAI/ALT) and subsequently making a decision regarding surgery are based primarily on diagnostic imaging and intra-articular hip joint injection techniques of unknown accuracy. Summarize and evaluate the diagnostic accuracy and clinical utility of various imaging modalities and injection techniques relevant to hip FAI/ALT. Systematic review with meta-analysis. A computer-assisted literature search was conducted of MEDLINE, CINAHL, and EMBASE databases using keywords related to diagnostic accuracy of hip joint pathologic changes. The PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) guidelines were used for the search and reporting phases of the study. Quality assessment of bias and applicability was conducted using the Quality of Diagnostic Accuracy Studies (QUADAS) tool. Random effects models were used to summarize sensitivities (SN), specificities (SP), likelihood ratios (+LR and -LR), diagnostic odds ratios (DOR), and respective confidence intervals (CI). The search strategy and assessment for risk of bias revealed 25 articles scoring above 10/14 on the items of the QUADAS. Four studies investigated FAI, and the data were not pooled. Twenty articles on ALT qualified for meta-analysis. Pretest probability of ALT in the studies in this review was 81% (72%-88%), while the pretest probability of FAI diagnosis was 74% (95% CI, 51%-91%). The meta-analysis showed that computed tomography arthrography (CTA) demonstrated the strongest overall diagnostic accuracy: pooled SN 0.91 (95% CI, 0.83-0.96); SP 0.89 (95% CI, 0.74-0.97); +LR 6.28 (95% CI, 2.78-14.21); -LR 0.11 (95% CI, 0.06-0.21); and DOR 64.38 (95% CI, 19.17-216.21). High pretest probability of disease was demonstrated. Positive imaging findings increased the probability that a labral tear existed by a minimal to small degree with the use of magnetic resonance imaging/magnetic resonance angiogram (MRI/MRA) and ultrasound (US

  7. Advantages of the first-derivative probe technique over the three- and four-parameter probe techniques in fusion plasmas diagnostics

    Czech Academy of Sciences Publication Activity Database

    Hasan, E.; Dimitrova, Miglena; Popov, T.; Ivanova, P.; Dejarnac, Renaud; Stöckel, Jan; Pánek, Radomír

    2018-01-01

    Roč. 13, č. 4 (2018), č. článku P04005. ISSN 1748-0221 R&D Projects: GA MŠk(CZ) LM2015045 Institutional support: RVO:61389021 Keywords : Plasma potential * electron temperature * bi-Maxwellian EEDF * Divertor Langmuir probes * three- and four-parameter probe techniques * first-derivative probe technique Subject RIV: BL - Plasma and Gas Discharge Physics OBOR OECD: 2.11 Other engineering and technologies Impact factor: 1.220, year: 2016 http://iopscience.iop.org/article/10.1088/1748-0221/13/04/P04005/meta

  8. Using Electronic Health Records to Build an Ophthalmologic Data Warehouse and Visualize Patients' Data.

    Science.gov (United States)

    Kortüm, Karsten U; Müller, Michael; Kern, Christoph; Babenko, Alexander; Mayer, Wolfgang J; Kampik, Anselm; Kreutzer, Thomas C; Priglinger, Siegfried; Hirneiss, Christoph

    2017-06-01

    To develop a near-real-time data warehouse (DW) in an academic ophthalmologic center to gain scientific use of increasing digital data from electronic medical records (EMR) and diagnostic devices. Database development. Specific macular clinic user interfaces within the institutional hospital information system were created. Orders for imaging modalities were sent by an EMR-linked picture-archiving and communications system to the respective devices. All data of 325 767 patients since 2002 were gathered in a DW running on an SQL database. A data discovery tool was developed. An exemplary search for patients with age-related macular degeneration, performed cataract surgery, and at least 10 intravitreal (excluding bevacizumab) injections was conducted. Data related to those patients (3 142 204 diagnoses [including diagnoses from other fields of medicine], 720 721 procedures [eg, surgery], and 45 416 intravitreal injections) were stored, including 81 274 optical coherence tomography measurements. A web-based browsing tool was successfully developed for data visualization and filtering data by several linked criteria, for example, minimum number of intravitreal injections of a specific drug and visual acuity interval. The exemplary search identified 450 patients with 516 eyes meeting all criteria. A DW was successfully implemented in an ophthalmologic academic environment to support and facilitate research by using increasing EMR and measurement data. The identification of eligible patients for studies was simplified. In future, software for decision support can be developed based on the DW and its structured data. The improved classification of diseases and semiautomatic validation of data via machine learning are warranted. Copyright © 2017 Elsevier Inc. All rights reserved.

  9. System of the ophthalmologic help premature children with retinopathy of prematurity in the Central region of Russia

    Directory of Open Access Journals (Sweden)

    A. V. Tereshchenko

    2014-07-01

    Full Text Available Purpose: Functional results analysis of ophthalmologic help system for premature infants, which includes the full cycle of early revelation, treatment and regular medical check-up activities for patients with ROP in Central region of Russia.Methods: Fields for ROP screening were performed in premature infants medical care units by clinic specialists. Infants with re- vealed ROP were directed to Kaluga Branch of IRtC «Eye Microsurgery» for detailed diagnostic examination and subsequent treatment and monitoring.Results: In 2003-2011 454 fields in Kaluga, tula, Bryansk, and Orel regions were made. 8861 infants were examined. ROP was found in 1834 infants (20.7%. 823 different interventions for infants with active ROP were performed: 737 retinal lasercoagulations, 3-ports vitrectomy — 72, lensvitrectomy — 14. the total efficacy of the treatment was 92.9%.Conclusion: the ophthalmologic help system for premature infants in Central region of Russia combines all directions from de-tailed diagnostic to hich-technology treatment. It allows to reproduce one all over the Russian Federation territory.

  10. System of the ophthalmologic help premature children with retinopathy of prematurity in the Central region of Russia

    Directory of Open Access Journals (Sweden)

    A. V. Tereshchenko

    2012-01-01

    Full Text Available Purpose: Functional results analysis of ophthalmologic help system for premature infants, which includes the full cycle of early revelation, treatment and regular medical check-up activities for patients with ROP in Central region of Russia.Methods: Fields for ROP screening were performed in premature infants medical care units by clinic specialists. Infants with re- vealed ROP were directed to Kaluga Branch of IRtC «Eye Microsurgery» for detailed diagnostic examination and subsequent treatment and monitoring.Results: In 2003-2011 454 fields in Kaluga, tula, Bryansk, and Orel regions were made. 8861 infants were examined. ROP was found in 1834 infants (20.7%. 823 different interventions for infants with active ROP were performed: 737 retinal lasercoagulations, 3-ports vitrectomy — 72, lensvitrectomy — 14. the total efficacy of the treatment was 92.9%.Conclusion: the ophthalmologic help system for premature infants in Central region of Russia combines all directions from de-tailed diagnostic to hich-technology treatment. It allows to reproduce one all over the Russian Federation territory.

  11. Facilities and techniques for x-ray diagnostic calibration in the 100-eV to 100-keV energy range

    International Nuclear Information System (INIS)

    Gaines, J.L.; Wittmayer, F.J.

    1986-01-01

    The Lawrence Livermore National Laboratory (LLNL) has been a pioneer in the field of x-ray diagnostic calibration for more than 20 years. The authors built steady state x-ray sources capable of supplying fluorescent lines of high spectral purity in the 100-eV to 100-keV energy range, and these sources have been used in the calibration of x-ray detectors, mirrors, crystals, filters, and film. This paper discusses their calibration philosophy and techniques, and describes some of the x-ray sources. Examples of actual calibration data are presented as well

  12. Facilities and Techniques for X-Ray Diagnostic Calibration in the 100-eV to 100-keV Energy Range

    Science.gov (United States)

    Gaines, J. L.; Wittmayer, F. J.

    1986-08-01

    The Lawrence Livermore National Laboratory (LLNL) has been a pioneer in the field of x-ray diagnostic calibration for more than 20 years. We have built steady state x-ray sources capable of supplying fluorescent lines of high spectral purity in the 100-eV to 100-keV energy range, and these sources have been used in the calibration of x-ray detectors, mirrors, crystals, filters, and film. This paper discusses our calibration philosophy and techniques, and describes some of our x-ray sources. Examples of actual calibration data are presented as well.

  13. Facilities and techniques for x-ray diagnostic calibration in the 100-eV to 100-keV energy range

    International Nuclear Information System (INIS)

    Gaines, J.L.; Wittmayer, F.J.

    1986-06-01

    The Lawrence Livermore National Laboratory (LLNL) has been a pioneer in the field of x-ray diagnostic calibration for more than 20 years. We have built steady state x-ray sources capable of supplying fluorescent lines of high spectral purity in the 100-eV to 100-keV energy range, and these sources have been used in the calibration of x-ray detectors, mirrors, crystals, filters, and film. This paper discusses our calibration philosophy and techniques, and describes some of our x-ray sources. Examples of actual calibration data are presented as well

  14. Application of the denaturing gradient gel electrophoresis (DGGE) technique as an efficient diagnostic tool for ciliate communities in soil.

    Science.gov (United States)

    Jousset, Alexandre; Lara, Enrique; Nikolausz, Marcell; Harms, Hauke; Chatzinotas, Antonis

    2010-02-01

    Ciliates (or Ciliophora) are ubiquitous organisms which can be widely used as bioindicators in ecosystems exposed to anthropogenic and industrial influences. The evaluation of the environmental impact on soil ciliate communities with methods relying on morphology-based identification may be hampered by the large number of samples usually required for a statistically supported, reliable conclusion. Cultivation-independent molecular-biological diagnostic tools are a promising alternative to greatly simplify and accelerate such studies. In this present work a ciliate-specific fingerprint method based on the amplification of a phylogenetic marker gene (i.e. the 18S ribosomal RNA gene) with subsequent analysis by denaturing gradient gel electrophoresis (DGGE) was developed and used to monitor community shifts in a polycyclic aromatic hydrocarbon (PAH) polluted soil. The semi-nested approach generated ciliate-specific amplification products from all soil samples and allowed to distinguish community profiles from a PAH-polluted and a non-polluted control soil. Subsequent sequence analysis of excised bands provided evidence that polluted soil samples are dominated by organisms belonging to the class Colpodea. The general DGGE approach presented in this study might thus in principle serve as a fast and reproducible diagnostic tool, complementing and facilitating future ecological and ecotoxicological monitoring of ciliates in polluted habitats. Copyright 2009 Elsevier B.V. All rights reserved.

  15. Neuro-ophthalmological conditions: Study of the clinical care pathway.

    Science.gov (United States)

    Layat, I; Challe, G; LeHoang, P; Bodaghi, B; Touitou, V

    2017-06-01

    Neuro-ophthalmologic conditions require specialized multidisciplinary management, both medical and surgical, for patients affected by visual loss due to nervous system disease. The primary goal of this study is to define the specificity of neuro-ophthalmology within the realm of visual health. The secondary goal is to review clinical care pathways by studying the organization of management, in terms of accessibility to care and personalization of the care pathway. A field study was carried out from February to June 2015, within the ophthalmology service of the Pitié-Salpêtrière University Medical Center in Paris. A 30-minute interview with the patient before or after his or her neuro-ophthalmology consultation was performed, to describe the clinical care pathway. The medical records of interviewed patients were also analyzed. Seventeen care pathways (10 women and 7 men) were reviewed. The mean age at appearance of visual involvement was 44.5 years (±8.4 years). If we exclude 3 patients over 66 years and retired, 35.71% were active, 35.71% were disabled, and 28.57% were on sick leave. Ten patients (58.82%) met the criteria for admission to long-term care. The first step had been carried out by local private practitioners. The first physician seen was the general medicine physician (59%), then the private ophthalmologist on an emergency basis (17%). On average, patients went through 8 steps during their care pathway (from 6 to 10 steps) and 14 medical departments were involved. The study showed collaboration with the other services of the University Hospital Department of Vision and Disabilities (notably with the Fondation Rothschild, the Quinze-Vingts National Ophthalmology Hospital, and the Fondation Sainte-Marie). In addition to rehabilitation services, health care professionals participating in the outpatient care of the patients included an orthoptist (11.7%), a psychologist (11.7%), and an optician specializing in low vision for visual aids. Finally

  16. Analysis of online patient education materials in pediatric ophthalmology.

    Science.gov (United States)

    John, Ann M; John, Elizabeth S; Hansberry, David R; Thomas, Prashant J; Guo, Suqin

    2015-10-01

    Patients increasingly consult online resources for healthcare information. The American Medical Association (AMA) and National Institutes of Health (NIH) recommend that online education resources be written between a 3rd- and 7th-grade level. This study assesses whether online health information abides by these guidelines. Ten pediatric ophthalmology conditions were entered into a commonly used search engine, Google.com, and analyzed using 10 validated readability scales. Scientific articles and articles written on patient forums were excluded. The 10 conditions--amblyopia, cataract, conjunctivitis, corneal abrasion, nystagmus, retinoblastoma, retinopathy of prematurity, strabismus, stye, and glaucoma--were also searched and analyzed separately from widely used websites, including Wikipedia and WebMD, as well as those of professional societies, including the American Association for Pediatric Ophthalmology and Strabismus (AAPOS) and the American Optometric Association (AOA). The majority of articles were written above recommended guidelines. All scales showed that the 100 articles were written at a mean grade-level of 11.75 ± 2.72. Only 12% of articles were written below a 9th-grade level and only 3% met recommended criteria. The articles accrued separately from Wikipedia, WebMD, AAPOS, and AOA also had average grade levels above the recommended guidelines. The readability of online patient education material exceeds NIH and AMA guidelines. This disparity can adversely affect caregiver comprehension of such resources and contribute to poor decision making. Pediatric ophthalmology online articles are generally written at a level too high for average caregiver comprehension. Revision of articles can increase satisfaction, improve outcomes, and facilitate the patient-ophthalmologist relationship. Published by Elsevier Inc.

  17. Image analysis in modern ophthalmology: from acquisition to computer assisted diagnosis and telemedicine

    Science.gov (United States)

    Marrugo, Andrés G.; Millán, María S.; Cristóbal, Gabriel; Gabarda, Salvador; Sorel, Michal; Sroubek, Filip

    2012-06-01

    Medical digital imaging has become a key element of modern health care procedures. It provides visual documentation and a permanent record for the patients, and most important the ability to extract information about many diseases. Modern ophthalmology thrives and develops on the advances in digital imaging and computing power. In this work we present an overview of recent image processing techniques proposed by the authors in the area of digital eye fundus photography. Our applications range from retinal image quality assessment to image restoration via blind deconvolution and visualization of structural changes in time between patient visits. All proposed within a framework for improving and assisting the medical practice and the forthcoming scenario of the information chain in telemedicine.

  18. Oral Vaccination with Heat-Inactivated Mycobacterium bovis Does Not Interfere with the Antemortem Diagnostic Techniques for Tuberculosis in Goats

    Directory of Open Access Journals (Sweden)

    Alvaro Roy

    2017-08-01

    Full Text Available Vaccination against tuberculosis (TB is prohibited in cattle or other species subjected to specific TB eradication campaigns, due to the interference that it may cause with the official diagnostic tests. However, immunization with a heat-inactivated (HI Mycobacterium bovis vaccine via the oral route has been suggested to overcome this issue. In this study, the main goal was to assess the interference of the HI vaccine by different routes of administration using a previous vaccination and re-vaccination (boosting protocol. TB-free kid goats were divided into three groups: oral (n = 16, intramuscular (IM; n = 16, and control (n = 16. Results showed that there was a significant difference in the percentage of animals positive to the single intradermal test (SIT and blood based interferon-gamma release assay (IGRA caused by vaccination when performed in the IM group compared to the oral group (p < 0.001. Nevertheless, no positivity to the SIT or IGRA test was observed in orally vaccinated goats regardless of the different interpretation criteria applied. None of the groups presented positive antibody titers using an in-house ELISA and samples collected 2 months after the boost. These results suggest the potential usefulness of the HI vaccine by the oral route in goats to minimize the interference on diagnostic tests (skin and IGRA tests and reducing the necessity of defined antigens to replace the traditional purified protein derivatives for diagnosis. Finally, the results pave the way to future efficacy studies in goats using different routes of HI vaccination.

  19. Uses and complications of mitomycin C in ophthalmology.

    Science.gov (United States)

    Mearza, Ali A; Aslanides, Ioannis M

    2007-01-01

    Mitomycin C is a chemotherapeutic agent that acts by inhibiting DNA synthesis. Its use and application in ophthalmology has been increasing in recent years because of its modulatory effects on wound healing. Current applications include pterygium surgery, glaucoma surgery, corneal refractive surgery, cicatricial eye disease, conjunctival neoplasia and allergic eye disease. Although it has been used successfully in these conditions, it has also been associated with significant complications. This article reviews the current trends and uses of mitomycin C in the eye and its reported complications.

  20. [Platforms are needed for innovative basic research in ophthalmology].

    Science.gov (United States)

    Wang, Yi-qiang

    2012-07-01

    Basic research poses the cornerstone of technical innovation in all lines including medical sciences. Currently, there are shortages of professional scientists as well as technical supporting teams and facilities in the field of basic research of ophthalmology and visual science in China. Evaluation system and personnel policies are not supportive for innovative but high-risk-of-failure research projects. Discussion of reasons and possible solutions are given here to address these problems, aiming at promoting buildup of platforms hosting novel and important basic research in eye science in this country.

  1. PHYSICO-CHEMICAL CHARACTERIZATION OF POLYMERIC FILMS USED IN OPHTHALMOLOGY

    Directory of Open Access Journals (Sweden)

    Ioan Emanuel STAVARACHE

    2017-03-01

    Full Text Available The aim of the present work was to characterize the surface properties of (polymethylmethacrylate (PMMA foils used in ophathalmological applications. Thus, the morphology, chemical composition and surface energy of these PMMA foils are analyzed, by specific measurements, at the interface with different test liquids of interest in ophthalmology, i.e. distilled H2 O, physiological serum and ophthalmic solution of ReNu Multiplus, used for contact lens cleaning, hydration and disinfection. Also, a solution of Nostamine, known as a drug used in eye irritation and conjunctival inflammation, was tested.

  2. Diagnostic accuracy of magnetic resonance imaging techniques for treatment response evaluation in patients with high-grade glioma, a systematic review and meta-analysis

    Energy Technology Data Exchange (ETDEWEB)

    Dijken, Bart R.J. van [University of Groningen, University Medical Center Groningen Department of Radiology, Groningen (Netherlands); Laar, Peter Jan van; Hoorn, Anouk van der [University of Groningen, University Medical Center Groningen Department of Radiology, Groningen (Netherlands); University of Groningen, University Medical Center Groningen, Center for Medical Imaging-North East Netherlands, Groningen (Netherlands); Holtman, Gea A. [University of Groningen, University Medical Center Groningen, Department of General Practice, Groningen (Netherlands)

    2017-10-15

    Treatment response assessment in high-grade gliomas uses contrast enhanced T1-weighted MRI, but is unreliable. Novel advanced MRI techniques have been studied, but the accuracy is not well known. Therefore, we performed a systematic meta-analysis to assess the diagnostic accuracy of anatomical and advanced MRI for treatment response in high-grade gliomas. Databases were searched systematically. Study selection and data extraction were done by two authors independently. Meta-analysis was performed using a bivariate random effects model when ≥5 studies were included. Anatomical MRI (five studies, 166 patients) showed a pooled sensitivity and specificity of 68% (95%CI 51-81) and 77% (45-93), respectively. Pooled apparent diffusion coefficients (seven studies, 204 patients) demonstrated a sensitivity of 71% (60-80) and specificity of 87% (77-93). DSC-perfusion (18 studies, 708 patients) sensitivity was 87% (82-91) with a specificity of 86% (77-91). DCE-perfusion (five studies, 207 patients) sensitivity was 92% (73-98) and specificity was 85% (76-92). The sensitivity of spectroscopy (nine studies, 203 patients) was 91% (79-97) and specificity was 95% (65-99). Advanced techniques showed higher diagnostic accuracy than anatomical MRI, the highest for spectroscopy, supporting the use in treatment response assessment in high-grade gliomas. (orig.)

  3. Image based measurement techniques for aircraft propeller flow diagnostics : Propeller slipstream investigations at high-lift conditions and thrust reverse

    NARCIS (Netherlands)

    Roosenboom, E.W.M.

    2011-01-01

    The aim of the thesis is to measure the propeller slipstream properties (velocity and vorticity) and to assess the unsteady and instantaneous behavior of the propeller flow field at high disk loadings, zero thrust and thrust reverse using the image based measurement techniques. Along with its

  4. Diagnostic significance of gas distension technique of the stomach with gas-forming agent on CT scan of stomach cancer

    International Nuclear Information System (INIS)

    Rho, Tae Jin; Song, Chang June; Choi, Joong Chan; Park, Cheong Hee; Cho, June Sik; Rhee, Byung Chull

    1988-01-01

    CT is a valuable method for preoperative staging of patients with stomach cancers. However, in patients with poor distension of the stomach and scanty fat between the stomach and adjacent organs, CT findings may indicate a false impression of gastric wall thickening and cannot provide the precise extent of stomach cancer. We studied the usefulness of gastric distension by gas-forming agent in 28 cases of pathologically confirmed gastric cancers on CT. Comparative analysis between CT findings and surgical pathologic findings was done in 22 cases who underwent surgery. The results were as follows; 1. Conventional CT failed to define the wall thickening or masses of the stomach, in 14 cases of 23 advanced gastric cancers, while CT with gas distension technique allowed good visualization in all advanced gastric cancers. 2. In 2 cases of 5 early gastric cancers, CT with gas distension technique could detect focal thickening of the gastric wall, even less than 1cm thickness. 3. Among 13 cases with indistinguishable border between stomach and liver on conventional CT, 7 cases were diagnosed as negative invasion on CT with gas distension technique and 5 cases of these were confirmed by surgery. 4. Among 11 cases with indistinguishable border between stomach and pancreas on conventional CT, 3 cases were diagnosed as negative invasion on CT with gas distension technique, all of which were confirmed by surgery. 5. There was no significant difference between conventional CT and CT with gas distension technique of the stomach to diagnose invasion into transverse colon, transverse colon, transverse mesocolon, lymph node metastasis, and various distant metastasis.

  5. Diagnostic significance of gas distension technique of the stomach with gas-forming agent on CT scan of stomach cancer

    Energy Technology Data Exchange (ETDEWEB)

    Rho, Tae Jin; Song, Chang June; Choi, Joong Chan; Park, Cheong Hee; Cho, June Sik; Rhee, Byung Chull [Chungnam National University College of Medicine, Dajeon (Korea, Republic of)

    1988-10-15

    CT is a valuable method for preoperative staging of patients with stomach cancers. However, in patients with poor distension of the stomach and scanty fat between the stomach and adjacent organs, CT findings may indicate a false impression of gastric wall thickening and cannot provide the precise extent of stomach cancer. We studied the usefulness of gastric distension by gas-forming agent in 28 cases of pathologically confirmed gastric cancers on CT. Comparative analysis between CT findings and surgical pathologic findings was done in 22 cases who underwent surgery. The results were as follows; 1. Conventional CT failed to define the wall thickening or masses of the stomach, in 14 cases of 23 advanced gastric cancers, while CT with gas distension technique allowed good visualization in all advanced gastric cancers. 2. In 2 cases of 5 early gastric cancers, CT with gas distension technique could detect focal thickening of the gastric wall, even less than 1cm thickness. 3. Among 13 cases with indistinguishable border between stomach and liver on conventional CT, 7 cases were diagnosed as negative invasion on CT with gas distension technique and 5 cases of these were confirmed by surgery. 4. Among 11 cases with indistinguishable border between stomach and pancreas on conventional CT, 3 cases were diagnosed as negative invasion on CT with gas distension technique, all of which were confirmed by surgery. 5. There was no significant difference between conventional CT and CT with gas distension technique of the stomach to diagnose invasion into transverse colon, transverse colon, transverse mesocolon, lymph node metastasis, and various distant metastasis.

  6. Diagnostic development

    International Nuclear Information System (INIS)

    Barnett, C.F.; Brisson, D.A.; Greco, S.E.

    1978-01-01

    During the past year the far-infrared or submillimeter diagnostic research program resulted in three major developments: (1) an optically pumped 0.385-μm D 2 O-laser oscillator-amplifier system was operated at a power level of 1 MW with a line width of less than 50 MHz; (2) a conical Pyrex submillimeter laser beam dump with a retention efficiency greater than 10 4 was developed for the ion temperature Thompson scattering experiment; and (3) a new diagnostic technique was developed that makes use of the Faraday rotation of a modulated submillimeter laser beam to determine plasma current profile. Measurements of the asymmetric distortion of the H/sub α/ (6563 A) spectral line profile show that the effective toroidal drift velocity, dv/sub two vertical bars i/dT/sub i/, may be used as an indicator of plasma quality and as a complement to other ion temperature diagnostics

  7. Rare gas dependence of vibration--vibration energy transfer processes: A diagnostic technique. Applications to CH2D2 and CH3F

    International Nuclear Information System (INIS)

    Apkarian, V.A.; Weitz, E.

    1979-01-01

    The rare gas dependence of V--V rates can be used as a diagnostic technique to identify different mechanisms of vibrational energy transfer and determine the rate constants for individual kinetic steps. The method is especially useful for the identification and measurement of rates of resonant vibrational energy transfer processes. Analytical and numerical solutions of pertinent model equations are presented and their range of applicability is discussed. The technique is applied to CH 2 D 2 and CH 3 F. In CH 2 D 2 results of studies on ν 9 , [ν 1 , ν 6 ] and states in the 2000 cm -1 region are presented where the application of the technique has made it possible to identify the pathways leading to population of these states and to assign rate constants to some of the steps involved. In CH 3 F, by studying the Ar dependence of the V--V rates of the [ν 2 , ν 5 ] and [ν 1 , ν 4 ] states it has been possible to construct a complete map of energy transfer pathways which can explain all experimental observations for this system, to date. The general applicability of the technique and its potential application to other systems is also considered

  8. Leadership in Ophthalmology: The Role of Physician-MBAs.

    Science.gov (United States)

    Pathipati, Akhilesh S; Tsai, James C

    2018-04-01

    As American health care evolves, an increasing number of doctors are pursuing MBAs. However, relatively little is known about how business training translates into their future careers. This study characterizes ophthalmologists who have completed MBAs and identifies opportunities for physician leadership in the field. Cross-sectional study. We identified 120 ophthalmologists who hold MBAs. We searched each individual's online profiles to collect information on demographics, training, and professional activities. Physician-MBAs in ophthalmology are 80% male; 80% are fellowship trained; and 28% are in primarily nonclinical roles and 55% participate in significant nonclinical activity. Hospital administration is most common (31%), followed by pharmaceutical administration (7%) and consulting (5%). Older ophthalmologist-MBAs were more likely to work in nonclinical roles, with 79% of those who completed residency before 2000 engaged in significant nonclinical activity compared to 30% of those who completed residency after 2000. The most common employers of physician-MBAs in ophthalmology are academic medical centers (43%), large group practices (30%), and private practices (13%). The majority of ophthalmologist-MBAs work in primarily clinical roles, although a sizable proportion hold nonclinical positions. Moving forward, we anticipate an increased role for physician leaders in health care administration, policy, and entrepreneurship. While formal management training is not necessary for these roles, a growing number of physicians have sought out MBAs to support their nonclinical interests. Copyright © 2018 Elsevier Inc. All rights reserved.

  9. [Microbiological and pharmacokinetic studies on flomoxef in ophthalmologic field].

    Science.gov (United States)

    Ooishi, M; Sakaue, F; Oomomo, A; Tazawa, H

    1989-05-01

    Microbiological and pharmacokinetic studies were carried out on flomoxef (FMOX, 6315-S), a new oxacephem parenteral antibiotic, in the ophthalmologic field. The results obtained are summarized as follows. FMOX has a broad antimicrobial activity spectrum against Gram-positive and Gram-negative bacteria. The MIC distribution against Staphylococcus aureus isolated from clinical cases was less than or equal to 0.20 - greater than or equal to 100 micrograms/ml with the peak value of 0.39 micrograms/ml. Concentrations of FMOX in aqueous humor and ocular tissues were determined after intravenous injection of 50 mg/kg to rabbits. FMOX showed a peak level of 2.2 micrograms/ml in the aqueous humor at 1/2 hour after administration with the ratio to serum level of 3.4%. Levels of FMOX in external and internal ocular tissues were 12.7 - 76.5 micrograms/g, less than 0.8 - 34.4 micrograms/g (ml) at 1/2 hour after administration, respectively. From these results, we concluded that FMOX may be expected to be a useful and valuable agent against infections in the ophthalmologic field.

  10. Ophthalmological evolution in hyperthyroid patients treated with radioactive iodine

    International Nuclear Information System (INIS)

    Marrero Rodriguez, Maria Teresa; Rodriguez Gonzalez, Julio Cesar; Alavez Martin, Ernesto

    2005-01-01

    This study was aimed at analyzing the ophthalmological evolution in hyperthyroid patients treated with radioactive iodine. 100 patients (88 females and 12 males) from the thyroid department of the National Institute of Endocrinology with clinical and biochemical diagnosis of hyperthyroidism and with a mean age of 40 + - 10 years old, were studied. These patients underwent a treatment with radioactive iodine at a dose of 80 m Ci/g of thyroid tissue. A bilateral ophthalmometry was performed to each patient before the treatment and 12 months after it. Mean ophthalmometry of the right eye was 14.51 + - 2.86 mm before the treatment and 13.92 + - 2.83 mm after the treatment, whereas for the left eye it was 14.98 + - 2.91 mm and 14.27 + - 2.83 mm , respectively. Taking into account the results of the ophthalmometry, we concluded that the use of radioactive iodine in the treatment of hyperthyroid patients had no negative results on the ophthalmological evolution of the studied patients

  11. Investigation of radiation protection of medical staff performing medical diagnostic examinations by using PET/CT technique

    International Nuclear Information System (INIS)

    Wrzesień, Małgorzata; Napolska, Katarzyna

    2015-01-01

    Positron emission tomography (PET) is now one of the most important methods in the diagnosis of cancer diseases. Due to the rapid growth of PET/CT centres in Poland in less than a decade, radiation protection and, consequently, the assessment of worker exposure to ionising radiation, emitted mainly by the isotope 18 F, have become essential issues. The main aim of the study was to analyse the doses received by workers employed in the Medical Diagnostic Centre. The analysis comprises a physicist, three nurses, three physicians, three technicians, as well as two administrative staff employees. High-sensitivity thermoluminescent detectors (TLDs) were used to measure the doses for medical staff. The personnel was classified into categories, among them employees having direct contact with the ‘source of radiation’— 18 FDG. The TLDs were placed on the fingertips of both hands and they were also attached at the level of eye lenses, thyroid and gonads depending on the assigned category. The highest dose of radiation was observed during the administration of the 18 FDG to the patients. In the case of the physicist, the highest dose was recorded during preparation of the radiopharmaceutical— 18 FDG. The body parts most exposed to ionizing radiation are the fingertips of the thumb, index and middle finger. (paper)

  12. An assessment of the 3D geometric surrogacy of shock timing diagnostic techniques for tuning experiments on the NIF

    Energy Technology Data Exchange (ETDEWEB)

    Robey, H F; Munro, D H; Spears, B K; Marinak, M M; Jones, O S; Patel, M V; Haan, S W; Salmonson, J D; Landen, O L [Lawrence Livermore National Laboratory, Livermore, CA (United States); Boehly, T R [Laboratory for Laser Energetics, Rochester, NY (United States); Nikroo, A [General Atomics, San Diego, CA (United States)], E-mail: robey1@llnl.gov

    2008-05-15

    Ignition capsule implosions planned for the National Ignition Facility (NIF) require a pulse shape with a carefully designed series of four steps, which launch a corresponding series of shocks through the ablator and DT ice shell. The relative timing of these shocks is critical for maintaining the DT fuel on a low adiabat. The current NIF specification requires that the timing of all four shocks be tuned to an accuracy of {<=} +/- 100ps. To meet these stringent requirements, dedicated tuning experiments are being planned to measure and adjust the shock timing on NIF. These tuning experiments will be performed in a modified hohlraum geometry, where a re-entrant Au cone is added to the standard NIF hohlraum to provide optical diagnostic (VISAR and SOP) access to the shocks as they break out of the ablator. This modified geometry is referred to as the 'keyhole' hohlraum and introduces a geometric difference between these tuning-experiments and the full ignition geometry. In order to assess the surrogacy of this modified geometry, 3D simulations using HYDRA [1] have been performed. The results from simulations of a quarter of the target geometry are presented. Comparisons of the hohlraum drive conditions and the resulting effect on the shock timing in the keyhole hohlraum are compared with the corresponding results for the standard ignition hohlraum.

  13. An assessment of the 3D geometric surrogacy of shock timing diagnostic techniques for tuning experiments on the NIF

    International Nuclear Information System (INIS)

    Robey, H F; Munro, D H; Spears, B K; Marinak, M M; Jones, O S; Patel, M V; Haan, S W; Salmonson, J D; Landen, O L; Boehly, T R; Nikroo, A

    2008-01-01

    Ignition capsule implosions planned for the National Ignition Facility (NIF) require a pulse shape with a carefully designed series of four steps, which launch a corresponding series of shocks through the ablator and DT ice shell. The relative timing of these shocks is critical for maintaining the DT fuel on a low adiabat. The current NIF specification requires that the timing of all four shocks be tuned to an accuracy of ≤ +/- 100ps. To meet these stringent requirements, dedicated tuning experiments are being planned to measure and adjust the shock timing on NIF. These tuning experiments will be performed in a modified hohlraum geometry, where a re-entrant Au cone is added to the standard NIF hohlraum to provide optical diagnostic (VISAR and SOP) access to the shocks as they break out of the ablator. This modified geometry is referred to as the 'keyhole' hohlraum and introduces a geometric difference between these tuning-experiments and the full ignition geometry. In order to assess the surrogacy of this modified geometry, 3D simulations using HYDRA [1] have been performed. The results from simulations of a quarter of the target geometry are presented. Comparisons of the hohlraum drive conditions and the resulting effect on the shock timing in the keyhole hohlraum are compared with the corresponding results for the standard ignition hohlraum

  14. Investigation of radiation protection of medical staff performing medical diagnostic examinations by using PET/CT technique.

    Science.gov (United States)

    Wrzesień, Małgorzata; Napolska, Katarzyna

    2015-03-01

    Positron emission tomography (PET) is now one of the most important methods in the diagnosis of cancer diseases. Due to the rapid growth of PET/CT centres in Poland in less than a decade, radiation protection and, consequently, the assessment of worker exposure to ionising radiation, emitted mainly by the isotope (18)F, have become essential issues. The main aim of the study was to analyse the doses received by workers employed in the Medical Diagnostic Centre. The analysis comprises a physicist, three nurses, three physicians, three technicians, as well as two administrative staff employees. High-sensitivity thermoluminescent detectors (TLDs) were used to measure the doses for medical staff. The personnel was classified into categories, among them employees having direct contact with the 'source of radiation'-(18)FDG. The TLDs were placed on the fingertips of both hands and they were also attached at the level of eye lenses, thyroid and gonads depending on the assigned category. The highest dose of radiation was observed during the administration of the (18)FDG to the patients. In the case of the physicist, the highest dose was recorded during preparation of the radiopharmaceutical-(18)FDG. The body parts most exposed to ionizing radiation are the fingertips of the thumb, index and middle finger.

  15. IDENTIFICATION OF CANINE VISCERAL LEISHMANIASIS IN A PREVIOUSLY UNAFFECTED AREA BY CONVENTIONAL DIAGNOSTIC TECHNIQUES AND CELL-BLOCK FIXATION

    Directory of Open Access Journals (Sweden)

    Tuanne Rotti ABRANTES

    2016-01-01

    Full Text Available After the report of a second case of canine visceral leishmaniasis (CVL in São Bento da Lagoa, Itaipuaçu, in the municipality of Maricá, Rio de Janeiro State, an epidemiological survey was carried out, through active search, totaling 145 dogs. Indirect immunofluorescence assay (IFA, enzyme-linked immunosorbent assay (ELISA, and rapid chromatographic immunoassay based on dual-path platform (DPP(r were used to perform the serological examinations. The parasitological diagnosis of cutaneous fragments was performed by parasitological culture, histopathology, and immunohistochemistry. In the serological assessment, 21 dogs were seropositive by IFA, 17 by ELISA, and 11 by DPP(r, with sensitivity of 66.7%, 66.7% and 50%, and specificity of 87.2%, 90.2% and 94%, respectively for each technique. The immunohistochemistry of bone marrow using the cell-block technique presented the best results, with six positive dogs found, three of which tested negative by the other parasitological techniques. Leishmania sp. was isolated by parasitological culture in three dogs. The detection of autochthonous Leishmania infantum in Itaipuaçu, and the high prevalence of seropositive dogs confirm the circulation of this parasite in the study area and alert for the risk of expansion in the State of Rio de Janeiro.

  16. Systematic application of flame diagnostics techniques for performance and emissions development of modern combustion systems; Systematischer Einsatz der Flammendiagnostik fuer die Leistungs- und Emissionsentwicklung moderner Brennverfahren

    Energy Technology Data Exchange (ETDEWEB)

    Winklhofer, E.; Beidl, C.; Hirsch, A.; Piock, W. [AVL List GmbH, Graz (Austria)

    2004-07-01

    In engine engineering, the information and benefits gained from optical flame diagnostics, especially in the combination with thermodynamic and CFD analysis of airflow and combustion are well accepted. It is, however, a specific challenge to implement techniques which are well established in basic engine R and D into the processes of series development or engine calibration. Any technique taken over from successfull predevelopment applications, is expected to equally well support series development. But in order to do this, it must also be suited to easily blend into the procedures of standard multicylinder engine tests. Development speed and results quality improve consideraly, whenever engineers within their routine engine tests gain knowledge about and evaluation of flame properties which allow identification of possible improvements of combustion efficiency, power density and emissions in an early, upfront development phase. Diagnostic systems employed for such tasks make use of fiber optic sensors which in spark ignited engines may be implanted into the bodies of sensor spark plugs. Their mechanic, thermal and electric properties comply with those of the originals, thus enabling their continuous use on the test bed. The arrangement of standard fiber optic channels allows flame radiation monitoring either within the axial proximity of the sensor plug, or of the entire combustion chamber compression volume. Signal recording and signal analysis is accomplished with Visiolution system techniques. Test results are evaluated on the basis of Visiolution algorithms. Data reduction schemes provide numerical figures of merit, describing, e. g. direction, velocity and symmetry of a spark ignited flame kernel. When knock center distribution is analysed, actual distribution statistics are checked against best concept distributions, whenever diffusion flames are detected against expectations of ideal premixed flames, their position, timing and intensity is evaluated. Such

  17. Measuring the perceived quality of ophthalmology services in private organizations. A marketing perspective

    Science.gov (United States)

    Gheorghe, Iuliana Raluca; Gheorghe, Consuela-Mădălina; Purcărea, Victor Lorin

    2018-01-01

    Nowadays, the competition registered on the Romanian markets regarding the activity of private ophthalmology organizations has raised their interest in developing consumer-oriented strategies. The key factor that assures a differentiation as well as a competitive advantage is the service quality from a marketing perspective. Objectives: From a marketing perspective, service quality is measured as a perceived discrepancy between the consumers’ expectations and was actually performed in health care services. The most widely and validated measurement is the SERVQUAL scale. However, a variety of SERVQUAL scales have been applied in different health care environments without taking into consideration the specialty of the health care service. Thus, the objective of this paper was to measure the service quality in the Romanian ophthalmology private organizations using the SERVQUAL measurement, by identifying the SERVQUAL dimensions, which register the highest and the lowest gap scores. Materials and methods: The instrument for data collection was the SERVQUAL self-administered questionnaire that consisted of 22 items measured on a 5-point Likert scale. The sample size encompassed 100 participants and the sampling technique was the snowball. The internal consistency, validity and the reliability of the SERVQUAL scale was determined by the Cronbach’s alpha coefficients and factor analysis. The SERVQUAL questionnaire focused on 5 dimensions (tangibles, reliability, assurance, empathy and responsiveness) and each dimension, in its turn, was characterized by different items. Results: The mean age of the participants was 49.52 years, with a mean income of 3031 Romanian Currency and the mean period of wearing eyeglasses was 5 years (±2). Further, there were 47% females and 53% males. The overall internal consistency of the SERVQUAL scale, as well as the dimensions’ internal consistency were all above 0.7 and the factor analysis revealed that the items loaded properly on

  18. Measuring the perceived quality of ophthalmology services in private organizations. A marketing perspective.

    Science.gov (United States)

    Gheorghe, Iuliana Raluca; Gheorghe, Consuela-Mădălina; Purcărea, Victor Lorin

    2018-01-01

    Nowadays, the competition registered on the Romanian markets regarding the activity of private ophthalmology organizations has raised their interest in developing consumer-oriented strategies. The key factor that assures a differentiation as well as a competitive advantage is the service quality from a marketing perspective. From a marketing perspective, service quality is measured as a perceived discrepancy between the consumers' expectations and was actually performed in health care services. The most widely and validated measurement is the SERVQUAL scale. However, a variety of SERVQUAL scales have been applied in different health care environments without taking into consideration the specialty of the health care service. Thus, the objective of this paper was to measure the service quality in the Romanian ophthalmology private organizations using the SERVQUAL measurement, by identifying the SERVQUAL dimensions, which register the highest and the lowest gap scores. The instrument for data collection was the SERVQUAL self-administered questionnaire that consisted of 22 items measured on a 5-point Likert scale. The sample size encompassed 100 participants and the sampling technique was the snowball. The internal consistency, validity and the reliability of the SERVQUAL scale was determined by the Cronbach's alpha coefficients and factor analysis. The SERVQUAL questionnaire focused on 5 dimensions (tangibles, reliability, assurance, empathy and responsiveness) and each dimension, in its turn, was characterized by different items. The mean age of the participants was 49.52 years, with a mean income of 3031 Romanian Currency and the mean period of wearing eyeglasses was 5 years (±2). Further, there were 47% females and 53% males. The overall internal consistency of the SERVQUAL scale, as well as the dimensions' internal consistency were all above 0.7 and the factor analysis revealed that the items loaded properly on each dimension. Moreover, the gap scores of the

  19. Plasma Diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Zaveryaev, V [Kurchatov Institute, Moscow (Russian Federation); others, and

    2012-09-15

    The success in achieving peaceful fusion power depends on the ability to control a high temperature plasma, which is an object with unique properties, possibly the most complicated object created by humans. Over years of fusion research a new branch of science has been created, namely plasma diagnostics, which involves knowledge of almost all fields of physics, from electromagnetism to nuclear physics, and up-to-date progress in engineering and technology (materials, electronics, mathematical methods of data treatment). Historically, work on controlled fusion started with pulsed systems and accordingly the methods of plasma parameter measurement were first developed for short lived and dense plasmas. Magnetically confined hot plasmas require the creation of special experimental techniques for diagnostics. The diagnostic set is the most scientifically intensive part of a plasma device. During many years of research operation some scientific tasks have been solved while new ones arose. New tasks often require significant changes in the diagnostic system, which is thus a very flexible part of plasma machines. Diagnostic systems are designed to solve several tasks. As an example here are the diagnostic tasks for the International Thermonuclear Experimental Reactor - ITER: (1) Measurements for machine protection and basic control; (2) Measurements for advanced control; (3) Additional measurements for performance evaluation and physics. Every new plasma machine is a further step along the path to the main goal - controlled fusion - and nobody knows in advance what new phenomena will be met on the way. So in the planning of diagnostic construction we should keep in mind further system upgrading to meet possible new scientific and technical challenges. (author)

  20. Veterinary Molecular Diagnostics

    NARCIS (Netherlands)

    Roest, H.I.J.; Engelsma, M.Y.; Weesendorp, E.; Bossers, A.; Elbers, A.R.W.

    2017-01-01

    In veterinary molecular diagnostics, samples originating from animals are tested. Developments in the farm animals sector and in our societal attitude towards pet animals have resulted in an increased demand for fast and reliable diagnostic techniques. Molecular diagnostics perfectly matches this

  1. Paradigm Shifts in Ophthalmic Diagnostics.

    Science.gov (United States)

    Sebag, J; Sadun, Alfredo A; Pierce, Eric A

    2016-08-01

    Future advances in ophthalmology will see a paradigm shift in diagnostics from a focus on dysfunction and disease to better measures of psychophysical function and health. Practical methods to define genotypes will be increasingly important and non-invasive nanotechnologies are needed to detect molecular changes that predate histopathology. This is not a review nor meant to be comprehensive. Specific topics have been selected to illustrate the principles of important paradigm shifts that will influence the future of ophthalmic diagnostics. It is our impression that future evaluation of vision will go beyond visual acuity to assess ocular health in terms of psychophysical function. The definition of disease will incorporate genotype into what has historically been a phenotype-centric discipline. Non-invasive nanotechnologies will enable a paradigm shift from disease detection on a cellular level to a sub-cellular molecular level. Vision can be evaluated beyond visual acuity by measuring contrast sensitivity, color vision, and macular function, as these provide better insights into the impact of aging and disease. Distortions can be quantified and the psychophysical basis of vision can be better evaluated than in the past by designing tests that assess particular macular cell function(s). Advances in our understanding of the genetic basis of eye diseases will enable better characterization of ocular health and disease. Non-invasive nanotechnologies can assess molecular changes in the lens, vitreous, and macula that predate visible pathology. Oxygen metabolism and circulatory physiology are measurable indices of ocular health that can detect variations of physiology and early disease. This overview of paradigm shifts in ophthalmology suggests that the future will see significant improvements in ophthalmic diagnostics. The selected topics illustrate the principles of these paradigm shifts and should serve as a guide to further research and development. Indeed

  2. On Thermoeconomic Diagnosis of a Fouled Direct Expansion Coil: Effects of Induced Malfunctions on Quantitative Performance of the Diagnostic Technique

    Directory of Open Access Journals (Sweden)

    Antonio Piacentino

    2017-06-01

    Full Text Available Thermoeconomic diagnosis represents a promising technique for the detection ofcommon faults in refrigeration systems, which are responsible of degradation in theirenergetic performance. Recently, the authors have carried out a sensitivity analysis of theperformance of this method to the thermodynamic conditions of inlet air and to thegeometry of the direct expansion coil, in case of degradation induced by evaporatorfouling. The analysis showed that the method is able to detect this fault, but sometimes itsquantitative assessments are not satisfactory. In order to understand more in-depth theorigin of such results and identify margins for refinement of the technique, this paper isaimed at evaluating at what extent changes in the exergetic performance of faults-freecomponents may negatively influence the model capability to detect the fouledevaporator and quantify the consequent additional exergy consumption. The resultssuggest that the method is particularly sensitive to the cost of “induced malfunctions” onthe compressor and the condenser, especially when low coil depth or high relativehumidity of inlet air are considered.

  3. 2D and 3D optical diagnostic techniques applied to Madonna dei Fusi by Leonardo da Vinci

    Science.gov (United States)

    Fontana, R.; Gambino, M. C.; Greco, M.; Marras, L.; Materazzi, M.; Pampaloni, E.; Pelagotti, A.; Pezzati, L.; Poggi, P.; Sanapo, C.

    2005-06-01

    3D measurement and modelling have been traditionally applied to statues, buildings, archeological sites or similar large structures, but rarely to paintings. Recently, however, 3D measurements have been performed successfully also on easel paintings, allowing to detect and document the painting's surface. We used 3D models to integrate the results of various 2D imaging techniques on a common reference frame. These applications show how the 3D shape information, complemented with 2D colour maps as well as with other types of sensory data, provide the most interesting information. The 3D data acquisition was carried out by means of two devices: a high-resolution laser micro-profilometer, composed of a commercial distance meter mounted on a scanning device, and a laser-line scanner. The 2D data acquisitions were carried out using a scanning device for simultaneous RGB colour imaging and IR reflectography, and a UV fluorescence multispectral image acquisition system. We present here the results of the techniques described, applied to the analysis of an important painting of the Italian Reinassance: `Madonna dei Fusi', attributed to Leonardo da Vinci.

  4. Assessment of African Swine Fever Diagnostic Techniques as a Response to the Epidemic Outbreaks in Eastern European Union Countries: How To Improve Surveillance and Control Programs.

    Science.gov (United States)

    Gallardo, C; Nieto, R; Soler, A; Pelayo, V; Fernández-Pinero, J; Markowska-Daniel, I; Pridotkas, G; Nurmoja, I; Granta, R; Simón, A; Pérez, C; Martín, E; Fernández-Pacheco, P; Arias, M

    2015-08-01

    This study represents a complete comparative analysis of the most widely used African swine fever (ASF) diagnostic techniques in the European Union (EU) using field and experimental samples from animals infected with genotype II ASF virus (ASFV) isolates circulating in Europe. To detect ASFV, three different PCRs were evaluated in parallel using 785 field and experimental samples. The results showed almost perfect agreement between the Universal ProbeLibrary (UPL-PCR) and the real-time (κ = 0.94 [95% confidence interval {CI}, 0.91 to 0.97]) and conventional (κ = 0.88 [95% CI, 0.83 to 0.92]) World Organisation for Animal Health (OIE)-prescribed PCRs. The UPL-PCR had greater diagnostic sensitivity for detecting survivors and allows earlier detection of the disease. Compared to the commercial antigen enzyme-linked immunosorbent assay (ELISA), good-to-moderate agreement (κ = 0.67 [95% CI, 0.58 to 0.76]) was obtained, with a sensitivity of 77.2% in the commercial test. For ASF antibody detection, five serological methods were tested, including three commercial ELISAs, the OIE-ELISA, and the confirmatory immunoperoxidase test (IPT). Greater sensitivity was obtained with the IPT than with the ELISAs, since the IPT was able to detect ASF antibodies at an earlier point in the serological response, when few antibodies are present. The analysis of the exudate tissues from dead wild boars showed that IPT might be a useful serological tool for determining whether or not animals had been exposed to virus infection, regardless of whether antibodies were present. In conclusion, the UPL-PCR in combination with the IPT was the most trustworthy method for detecting ASF during the epidemic outbreaks affecting EU countries in 2014. The use of the most appropriate diagnostic tools is critical when implementing effective control programs. Copyright © 2015, American Society for Microbiology. All Rights Reserved.

  5. Assessment of African Swine Fever Diagnostic Techniques as a Response to the Epidemic Outbreaks in Eastern European Union Countries: How To Improve Surveillance and Control Programs

    Science.gov (United States)

    Nieto, R.; Soler, A.; Pelayo, V.; Fernández-Pinero, J.; Markowska-Daniel, I.; Pridotkas, G.; Nurmoja, I.; Granta, R.; Simón, A.; Pérez, C.; Martín, E.; Fernández-Pacheco, P.; Arias, M.

    2015-01-01

    This study represents a complete comparative analysis of the most widely used African swine fever (ASF) diagnostic techniques in the European Union (EU) using field and experimental samples from animals infected with genotype II ASF virus (ASFV) isolates circulating in Europe. To detect ASFV, three different PCRs were evaluated in parallel using 785 field and experimental samples. The results showed almost perfect agreement between the Universal ProbeLibrary (UPL-PCR) and the real-time (κ = 0.94 [95% confidence interval {CI}, 0.91 to 0.97]) and conventional (κ = 0.88 [95% CI, 0.83 to 0.92]) World Organisation for Animal Health (OIE)-prescribed PCRs. The UPL-PCR had greater diagnostic sensitivity for detecting survivors and allows earlier detection of the disease. Compared to the commercial antigen enzyme-linked immunosorbent assay (ELISA), good-to-moderate agreement (κ = 0.67 [95% CI, 0.58 to 0.76]) was obtained, with a sensitivity of 77.2% in the commercial test. For ASF antibody detection, five serological methods were tested, including three commercial ELISAs, the OIE-ELISA, and the confirmatory immunoperoxidase test (IPT). Greater sensitivity was obtained with the IPT than with the ELISAs, since the IPT was able to detect ASF antibodies at an earlier point in the serological response, when few antibodies are present. The analysis of the exudate tissues from dead wild boars showed that IPT might be a useful serological tool for determining whether or not animals had been exposed to virus infection, regardless of whether antibodies were present. In conclusion, the UPL-PCR in combination with the IPT was the most trustworthy method for detecting ASF during the epidemic outbreaks affecting EU countries in 2014. The use of the most appropriate diagnostic tools is critical when implementing effective control programs. PMID:26041901

  6. The Iowa ophthalmology wet laboratory curriculum for teaching and assessing cataract surgical competency

    NARCIS (Netherlands)

    Lee, Andrew G.; Greenlee, Emily; Oetting, Thomas A.; Beaver, Hilary A.; Johnson, A. Tim; Boldt, H. Culver; Abramoff, Michael; Olson, Richard; Carter, Keith

    2007-01-01

    Purpose To describe an ophthalmology wet laboratory (OWL) curriculum for residents in training. Methods Systematic literature review and selection of best practices for use in the OWL learning plan from a single academic ophthalmology program. Results A pretest and posttest of cognitive

  7. The Role of Retinal Imaging and Portable Screening Devices in Tele-ophthalmology Applications for Diabetic Retinopathy Management.

    Science.gov (United States)

    DeBuc, Delia Cabrera

    2016-12-01

    In the years since its introduction, retinal imaging has transformed our capability to visualize the posterior pole of the eye. Increasing practical advances in mobile technology, regular monitoring, and population screening for diabetic retinopathy management offer the opportunity for further development of cost-effective applications through remote assessment of the diabetic eye using portable retinal cameras, smart-phone-based devices and telemedicine networks. Numerous retinal imaging methods and mobile technologies in tele-ophthalmology applications have been reported for diabetic retinopathy screening and management. They provide several advantages of automation, sensitivity, specificity, portability, and miniaturization for the development of point-of-care diagnostics for eye complications in diabetes. The aim of this paper is to review the role of retinal imaging and mobile technologies in tele-ophthalmology applications for diabetic retinopathy screening and management. At large, although improvements in current technology and telemedicine services are still needed, telemedicine has demonstrated to be a worthy tool to support health caregivers in the effective management and prevention of diabetes and its complications.

  8. Medical students perception of undergraduate ophthalmology training in Nnamdi Azikiwe University Nnewi Campus.

    Science.gov (United States)

    Onyekwe, L O; Nwosu, S N N

    2006-12-01

    To determine the perception and aspiration of medical students towards ophthalmology. Information for the study was obtained through forced-choice questionnaire set to 102 medical students in 2000/2001 graduating class in Nnamdi Azikiwe University. One hundred questionnaires were completed. As a specialty of choice ophthalmology ranked fourth {16.0%} as a first choice; second {21.0%} as a second choice and first {26.0%} as a third choice. Ninety-five of respondents found ophthalmology training useful. This cohort of medical students considered ophthalmic training in this institution essential and adequate. Undergraduate ophthalmic course should ensure an understanding of the basic principles of ophthalmology and should be designed to motivate the interest and confidence of the medical students in the specialty. Training period should be at least 4 weeks. With appropriate training ophthalmology can attract reasonable interest as a choice for specification.

  9. LASER CORRELATION SPECTROSCOPY (LCS AND ITS CLINICAL PERSPECTIVES IN OPHTHALMOLOGY

    Directory of Open Access Journals (Sweden)

    Karganov Mikhail

    2015-12-01

    Full Text Available The method of laser correlation spectroscopy (LCS is based on the analysis of the spectrum of quasielastic light scatter during coherent monochromatic laser irradiation of micro-particles in biological fluids (blood serum, urine, oropharyngeal washout fluid, tear fluid etc.. Spectrum provides information on dynamic processes in the analyzed system: translation motion of scattering particles and their orientation and conformation dynamics. Special procedures of cluster analysis make it possible to find out to which linkage group a particular spectrum belongs. LCS allows evaluation of sub-fractional composition of biological fluids in a wide range of molecular sizes (from 1 to 10,000 nm, which determines principal novelty of this approach in ophthalmology.

  10. Ophthalmology on social networking sites: an observational study of Facebook, Twitter, and LinkedIn

    Directory of Open Access Journals (Sweden)

    Micieli JA

    2015-02-01

    Full Text Available Jonathan A Micieli,1 Edmund Tsui2 1Department of Ophthalmology and Vision Sciences, University of Toronto, Toronto, ON, Canada; 2Department of Surgery, Dartmouth-Hitchcock Medical Center, Lebanon, NH, USA Background: The use of social media in ophthalmology remains largely unknown. Our aim was to evaluate the extent and involvement of ophthalmology journals, professional associations, trade publications, and patient advocacy and fundraising groups on social networking sites. Methods: An archived list of 107 ophthalmology journals from SCImago, trade publications, professional ophthalmology associations, and patient advocacy organizations were searched for their presence on Facebook, Twitter, and LinkedIn. Activity and popularity of each account was quantified by using the number of “likes” on Facebook, the number of followers on Twitter, and members on LinkedIn. Results: Of the 107 journals ranked by SCImago, 21.5% were present on Facebook and 18.7% were present on Twitter. Journal of Community Eye Health was the most popular on Facebook and JAMA Ophthalmology was most popular on Twitter. Among the 133 members of the International Council of Ophthalmology, 17.3% were present on Facebook, 12.8% were present on Twitter, and 7.5% were present on LinkedIn. The most popular on Facebook was the International Council of Ophthalmology, and the American Academy of Ophthalmology was most popular on Twitter and LinkedIn. Patient advocacy organizations were more popular on all sites compared with journals, professional association, and trade publications. Among the top ten most popular pages in each category, patient advocacy groups were most active followed by trade publications, professional associations, and journals. Conclusion: Patient advocacy groups lead the way in social networking followed by professional organizations and journals. Although some journals use social media, most have yet to engage its full potential and maximize the number of

  11. Evaluation of the anterior chamber angle in glaucoma: a report by the american academy of ophthalmology.

    Science.gov (United States)

    Smith, Scott D; Singh, Kuldev; Lin, Shan C; Chen, Philip P; Chen, Teresa C; Francis, Brian A; Jampel, Henry D

    2013-10-01

    gonioscopy. Longitudinal studies are needed to validate the diagnostic significance of the parameters measured by these instruments for prospectively identifying individuals at risk for PAC. Proprietary or commercial disclosure may be found after the references. Copyright © 2013 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  12. Scientometric analysis of published papers in global ophthalmology in the past ten years.

    Science.gov (United States)

    Yu, Zheng-Lu; Hu, Xin-Yue; Wang, Ying-Na; Ma, Zheng

    2017-01-01

    To investigate the published papers of ophthalmology in past ten years and explore the development of ophthalmology. The data of this study retrieved from Science Citation Index Expanded and downloaded online in November 2017, including all the papers with publication year from 2007-2016 were analyzed. The papers were based on the Web of Science category and the journals were based on the Journal Citation Report category. The number of ophthalmology papers increased from 7450 to 9089 during 2007 to 2017. The average rate increased 2.2% annually. USA accounts for one thirds of the total and two thirds of the highly cited papers. In Asia, China, Japan and South Korea were in Top 10 by the number of ophthalmology papers. UK, Germany, Japan and Australia also had great impact in global ophthalmology. The hot spots included endothelial growth factor, optical coherence tomography and open-angle glaucoma. USA is in the leading position in global ophthalmology. Part of Asian countries play an important role in the development of ophthalmology, but the impact needs to be improved.

  13. Prototype Development: Context-Driven Dynamic XML Ophthalmologic Data Capture Application

    Science.gov (United States)

    Schwei, Kelsey M; Kadolph, Christopher; Finamore, Joseph; Cancel, Efrain; McCarty, Catherine A; Okorie, Asha; Thomas, Kate L; Allen Pacheco, Jennifer; Pathak, Jyotishman; Ellis, Stephen B; Denny, Joshua C; Rasmussen, Luke V; Tromp, Gerard; Williams, Marc S; Vrabec, Tamara R; Brilliant, Murray H

    2017-01-01

    Background The capture and integration of structured ophthalmologic data into electronic health records (EHRs) has historically been a challenge. However, the importance of this activity for patient care and research is critical. Objective The purpose of this study was to develop a prototype of a context-driven dynamic extensible markup language (XML) ophthalmologic data capture application for research and clinical care that could be easily integrated into an EHR system. Methods Stakeholders in the medical, research, and informatics fields were interviewed and surveyed to determine data and system requirements for ophthalmologic data capture. On the basis of these requirements, an ophthalmology data capture application was developed to collect and store discrete data elements with important graphical information. Results The context-driven data entry application supports several features, including ink-over drawing capability for documenting eye abnormalities, context-based Web controls that guide data entry based on preestablished dependencies, and an adaptable database or XML schema that stores Web form specifications and allows for immediate changes in form layout or content. The application utilizes Web services to enable data integration with a variety of EHRs for retrieval and storage of patient data. Conclusions This paper describes the development process used to create a context-driven dynamic XML data capture application for optometry and ophthalmology. The list of ophthalmologic data elements identified as important for care and research can be used as a baseline list for future ophthalmologic data collection activities. PMID:28903894

  14. Plasma diagnostics discharge parameters and chemistry

    CERN Document Server

    Auciello, Orlando

    1989-01-01

    Plasma Diagnostics, Volume 1: Discharge Parameters and Chemistry covers seven chapters on the important diagnostic techniques for plasmas and details their use in particular applications. The book discusses optical diagnostic techniques for low pressure plasmas and plasma processing; plasma diagnostics for electrical discharge light sources; as well as Langmuir probes. The text also describes the mass spectroscopy of plasmas, microwave diagnostics, paramagnetic resonance diagnostics, and diagnostics in thermal plasma processing. Electrical engineers, nuclear engineers, microwave engineers, che

  15. Back pain in ophthalmology: National survey of Indian ophthalmologists

    Directory of Open Access Journals (Sweden)

    Ramesh Venkatesh

    2017-01-01

    Full Text Available Purpose: The aim is to assess the prevalence, severity, and associations of back pain among Indian ophthalmologists. Methods: A self-reporting questionnaire was sent to ophthalmologists with valid e-mail addresses registered with the All India Ophthalmological Society. The survey was open for responses for 2 months. Results: A total of 651 (5.96% responses were obtained; 394 (61% males and 257 (39% females. Half (50% of responses were obtained from doctors belonging to 31–40 years' age group. Two hundred and thirty (35% of the ophthalmologists had height ranging from 161 to 170 cm and 443 (68% had weight ranging from 51 to 75 kg. Four hundred and eighty-one (73.8% of the respondents had <15 years of ophthalmic experience. Cataract (346; 53.1% and general ophthalmology (342; 52.5% were commonly practised by the ophthalmologists. Time spent in the outpatient department (OPD was 39.37 ± 16.32 h/week and in the operating theater 13.64 ± 9.89 h/week, respectively. Self-reported prevalence of back pain was 70.5%. Fully 49% of respondents had low back pain, followed by neck pain (33% and upper extremity symptoms (16%. Age <50 years (odds ratio [OR] = 2.4485, female gender (OR = 2.0265, long working hours in OPD (OR = 1.6524, and performing retinal lasers and indirect ophthalmoscopy (OR = 3.3251 showed positive association with back pain. The intolerable back pain was noted in <7% of the respondents. Around 398 (61% respondents felt that their back pain was exacerbated while doing work and 86.6% felt that up to 5 h/week was lost due to persistent backache. Yoga and some form of exercise (74.3% was practised to alleviate back pain. Conclusion: Back pain symptoms appear to be common among ophthalmologists. Awkward posture and prolonged working hours are responsible for developing back pain among ophthalmologists. Performing yoga and regular exercises, modifications in instrumentation and creating a larger workforce of eye care practitioners are needed

  16. MR detection of retinal hemorrhages: correlation with graded ophthalmologic exam

    International Nuclear Information System (INIS)

    Beavers, Angela J.; Allbery, Sandra M.; Stagner, Anna M.; Hejkal, Thomas W.; Lyden, Elizabeth R.; Haney, Suzanne B.

    2015-01-01

    Dilated fundoscopic exam is considered the gold standard for detecting retinal hemorrhage, but expertise in obtaining this exam is not always immediately available. MRI can detect retinal hemorrhages, but correlation of the grade or severity of retinal hemorrhage on dilated fundoscopic exam with retinal hemorrhage visibility on MRI has not been described. To determine the value of standard brain protocol MRI in detecting retinal hemorrhage and to determine whether there is any correlation with MR detection of retinal hemorrhage and the dilated fundoscopic exam grade of hemorrhage. We conducted a retrospective chart review of 77 children <2 years old who were seen for head trauma from April 2007 to July 2013 and had both brain MRI and dilated fundoscopic exam or retinal camera images. A staff pediatric radiologist and radiology resident reviewed the MR images. Retinal hemorrhages were graded by a chief ophthalmology resident on a 12-point scale based on the retinal hemorrhage type, size, location and extent as seen on review of retinal camera images and detailed reports by ophthalmologists. Higher scores indicated increased severity of retinal hemorrhages. There was a statistically significant difference in the median grade of retinal hemorrhage examination between children who had retinal hemorrhage detected on MRI and children who did not have retinal hemorrhage detected on MRI (P = 0.02). When examination grade was categorized as low-grade (1-4), moderate-grade (5-8) or high-grade (>8) hemorrhage, there was a statistically significant association between exam grade and diagnosis based on MRI (P = 0.008). For example, only 14% of children with low-grade retinal hemorrhages were identified on MRI compared to 76% of children with high-grade hemorrhages. MR detection of retinal hemorrhage demonstrated a sensitivity of 61%, specificity of 100%, positive predictive value of 100% and negative predictive value of 63%. Retinal hemorrhage was best seen on the gradient

  17. Diagnostic Value of Multidetector CT and Its Multiplanar Reformation, Volume Rendering and Virtual Bronchoscopy Postprocessing Techniques for Primary Trachea and Main Bronchus Tumors.

    Directory of Open Access Journals (Sweden)

    Mingyue Luo

    Full Text Available To evaluate the diagnostic value of multidetector CT (MDCT and its multiplanar reformation (MPR, volume rendering (VR and virtual bronchoscopy (VB postprocessing techniques for primary trachea and main bronchus tumors.Detection results of 31 primary trachea and main bronchus tumors with MDCT and its MPR, VR and VB postprocessing techniques, were analyzed retrospectively with regard to tumor locations, tumor morphologies, extramural invasions of tumors, longitudinal involvements of tumors, morphologies and extents of luminal stenoses, distances between main bronchus tumors and trachea carinae, and internal features of tumors. The detection results were compared with that of surgery and pathology.Detection results with MDCT and its MPR, VR and VB were consistent with that of surgery and pathology, included tumor locations (tracheae, n = 19; right main bronchi, n = 6; left main bronchi, n = 6, tumor morphologies (endoluminal nodes with narrow bases, n = 2; endoluminal nodes with wide bases, n = 13; both intraluminal and extraluminal masses, n = 16, extramural invasions of tumors (brokethrough only serous membrane, n = 1; 4.0 mm-56.0 mm, n = 14; no clear border with right atelectasis, n = 1, longitudinal involvements of tumors (3.0 mm, n = 1; 5.0 mm-68.0 mm, n = 29; whole right main bronchus wall and trachea carina, n = 1, morphologies of luminal stenoses (irregular, n = 26; circular, n = 3; eccentric, n = 1; conical, n = 1 and extents (mild, n = 5; moderate, n = 7; severe, n = 19, distances between main bronchus tumors and trachea carinae (16.0 mm, n = 1; invaded trachea carina, n = 1; >20.0 mm, n = 10, and internal features of tumors (fairly homogeneous densities with rather obvious enhancements, n = 26; homogeneous density with obvious enhancement, n = 1; homogeneous density without obvious enhancement, n = 1; not enough homogeneous density with obvious enhancement, n = 1; punctate calcification with obvious enhancement, n = 1; low density

  18. Diagnostic Value of Multidetector CT and Its Multiplanar Reformation, Volume Rendering and Virtual Bronchoscopy Postprocessing Techniques for Primary Trachea and Main Bronchus Tumors.

    Science.gov (United States)

    Luo, Mingyue; Duan, Chaijie; Qiu, Jianping; Li, Wenru; Zhu, Dongyun; Cai, Wenli

    2015-01-01

    To evaluate the diagnostic value of multidetector CT (MDCT) and its multiplanar reformation (MPR), volume rendering (VR) and virtual bronchoscopy (VB) postprocessing techniques for primary trachea and main bronchus tumors. Detection results of 31 primary trachea and main bronchus tumors with MDCT and its MPR, VR and VB postprocessing techniques, were analyzed retrospectively with regard to tumor locations, tumor morphologies, extramural invasions of tumors, longitudinal involvements of tumors, morphologies and extents of luminal stenoses, distances between main bronchus tumors and trachea carinae, and internal features of tumors. The detection results were compared with that of surgery and pathology. Detection results with MDCT and its MPR, VR and VB were consistent with that of surgery and pathology, included tumor locations (tracheae, n = 19; right main bronchi, n = 6; left main bronchi, n = 6), tumor morphologies (endoluminal nodes with narrow bases, n = 2; endoluminal nodes with wide bases, n = 13; both intraluminal and extraluminal masses, n = 16), extramural invasions of tumors (brokethrough only serous membrane, n = 1; 4.0 mm-56.0 mm, n = 14; no clear border with right atelectasis, n = 1), longitudinal involvements of tumors (3.0 mm, n = 1; 5.0 mm-68.0 mm, n = 29; whole right main bronchus wall and trachea carina, n = 1), morphologies of luminal stenoses (irregular, n = 26; circular, n = 3; eccentric, n = 1; conical, n = 1) and extents (mild, n = 5; moderate, n = 7; severe, n = 19), distances between main bronchus tumors and trachea carinae (16.0 mm, n = 1; invaded trachea carina, n = 1; >20.0 mm, n = 10), and internal features of tumors (fairly homogeneous densities with rather obvious enhancements, n = 26; homogeneous density with obvious enhancement, n = 1; homogeneous density without obvious enhancement, n = 1; not enough homogeneous density with obvious enhancement, n = 1; punctate calcification with obvious enhancement, n = 1; low density without

  19. Use of amniotic membrane in ophthalmology surgery, first cases

    International Nuclear Information System (INIS)

    Aguirre, P.; Ogrodnik, M.T.; Zarate, H; Silva, S.; Azocar, M.; Hitschfeld, M.

    2008-01-01

    The results obtained with the implant of amniotic membranes have propitiated their use in different medical fields.One of the most important barriers that have to be solved is the risk to transmit illness from donor to patient. A cooperative work between the Comision Chilena de Energia Nuclear (CCHEN) and the Complejo de Salud San Borja Arriaran (CSSBA) has been done to prepare the membranes with the main purpose of assuring the quality and effectiveness of the tissue, since the procurement to the moment that it is used as biological apposite. In the production of this radiation sterilized tissue, we have followed a strict protocol that considers selection criteria for each donor, obtainment and processing of each membrane in aseptic conditions including the washing steps, cutting,drying in laminar flow hood, packing and identification.This is followed by sterilization with gamma radiation,quality controls which include the count of colonies formation units and the assurance of sterility. The average size of each membrane was 2 x 2 cm. The membranes have been used in 57 patients since 2002 up to date on surgical procedures of ophthalmology specialty: 38 Pterigeon, 3 Recoverment of anophthalmic cavity, 4 Corneal perforations, 2 Sclera ulcers, 1 extirpation of a conjunctiva inclusion cyst and 1 Reconstruction of Lachrymal sac, with very good results

  20. Surgical adhesives in ophthalmology: history and current trends.

    Science.gov (United States)

    Guhan, Samantha; Peng, Si-Liang; Janbatian, Hrag; Saadeh, Stephanie; Greenstein, Stephen; Al Bahrani, Faisal; Fadlallah, Ali; Yeh, Tsai-Chu; Melki, Samir A

    2018-03-26

    Tissue adhesives are gaining popularity in ophthalmology, as they could potentially reduce the complications associated with current surgical methods. An ideal tissue adhesive should have superior tensile strength, be non-toxic and anti-inflammatory, improve efficiency and be cost-effective. Both synthetic and biological glues are available. The primary synthetic glues include cyanoacrylate and the recently introduced polyethylene glycol (PEG) derivatives, while most biological glues are composed of fibrin. Cyanoacrylate has a high tensile strength, but rapidly polymerises upon contact with any fluid and has been associated with histotoxicity. Fibrin induces less toxic and inflammatory reactions, and its polymerisation time can be controlled. Tensile strength studies have shown that fibrin is not as strong as cyanoacrylate. While more research is needed, PEG variants currently appear to have the most promise. These glues are non-toxic, strong and time-effective. Through MEDLINE and internet searches, this paper presents a systematic review of the current applications of surgical adhesives to corneal, glaucoma, retinal, cataract and strabismus surgeries. Our review suggests that surgical adhesives have promise to reduce problems in current ophthalmic surgical procedures. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  1. An outbreak of epidemic keratoconjunctivitis at an outpatient ophthalmology clinic

    Directory of Open Access Journals (Sweden)

    Timothy J Doyle

    2010-12-01

    Full Text Available Epidemic keratoconjunctivitis (EKC is an acute eye infection caused by adenovirus. We investigated an outbreak of EKC at an outpatient ophthalmology practice in the context of a suspected community wide increase in EKC activity. A site visit was made to the facility reporting the outbreak. A line list was created of patients clinically diagnosed with EKC at the practice during the previous 5 months. A questionnaire was faxed to all other licensed ophthalmologists in the county regarding recent EKC activity in their facility. Descriptive data analyses were conducted. The outbreak facility reported 37 patients clinically diagnosed with EKC during the previous 5 months. In addition, the single ophthalmologist at the practice also had symptoms compatible with EKC during the outbreak period. Specimens were collected on 4 patients and all were positive for adenovirus serotype 8. Forty percent of ophthalmologists surveyed in the county saw at least one EKC patient in the previous 3 months, and 20% reported a perceived increase in EKC activity in recent months over normal seasonal patterns. The outbreak at the facility likely began as part of a widespread community increase in EKC that may have been amplified at the facility through nosocomial transmission. Medical providers experiencing increases in EKC activity above seasonally expected norms should contact their public health department for assistance with etiologic diagnoses and outbreak control.

  2. A secure and synthesis tele-ophthalmology system.

    Science.gov (United States)

    Wei, Zhuo; Wu, Yongdong; Deng, Robert H; Yu, Shengsheng; Yao, Haixia; Zhao, Zhigang; Ngoh, Lek Heng; Han, Lim Tock; Poh, Eugenie W T

    2008-10-01

    This paper describes a secure and synthesis ophthalmology telemedicine system, referred to as TeleOph. Under a Secure Socket Layer (SSL) channel, patient prerecorded data can be safely transferred via the Internet. With encrypted videoconference and white-board, the system not only supports hospital-to-clinic consultation, but also supplies hospital-tohospital joint discussion. Based on Directshow technology (Microsoft Corporation, Redmond, WA), video cameras connected to the computer by firewire can be captured and controlled to sample video data. By using TWAIN technology, the system automatically identifies networked still cameras (on fundus and slitlamp devices) and retrieves images. All the images are stored in a selected format (such as JPEG, DICOM, BMP). Besides offline-transferring prerecorded data, the system also supplies online sampling of patient data (real-time capturing from remote places). The system was deployed at Tan Tock Seng Hospital, Singapore and Ang Mo Kio, Singapore, where 100 patients were enrolled in the system for examination. TeleOph can be successfully used for patient consultation, and hospital joint discussion. Meanwhile, TeleOph can supply both offline and online sampling of patient data.

  3. Optical design and tolerancing of an ophthalmological system

    Science.gov (United States)

    Sieber, Ingo; Martin, Thomas; Yi, Allen; Li, Likai; Rübenach, Olaf

    2014-09-01

    Tolerance analysis by means of simulation is an essential step in system integration. Tolerance analysis allows for predicting the performance of a system setup of real manufactured parts and for an estimation of the yield with respect to evaluation figures, such as performance requirements, systems specification or cost demands. Currently, optical freeform optics is gaining importance in optical systems design. The performance of freeform optics often strongly depends on the manufacturing accuracy of the surfaces. For this reason, a tolerance analysis with respect to the fabrication accuracy is of crucial importance. The characterization of form tolerances caused by the manufacturing process is based on the definition of straightness, flatness, roundness, and cylindricity. In case of freeform components, however, it is often impossible to define a form deviation by means of this standard classification. Hence, prediction of the impact of manufacturing tolerances on the optical performance is not possible by means of a conventional tolerance analysis. To carry out a tolerance analysis of the optical subsystem, including freeform optics, metrology data of the fabricated surfaces have to be integrated into the optical model. The focus of this article is on design for manufacturability of freeform optics with integrated alignment structures and on tolerance analysis of the optical subsystem based on the measured surface data of manufactured optical freeform components with respect to assembly and manufacturing tolerances. This approach will be reported here using an ophthalmological system as an example.

  4. Cerebral visual impairment in children: Causes and associated ophthalmological problems.

    Science.gov (United States)

    Pehere, Niranjan; Chougule, Pratik; Dutton, Gordon N

    2018-06-01

    The aim of this study is to identify common causes, associated ophthalmological abnormalities, and systemic comorbidities in children in Andhra Pradesh, India, with cerebral visual impairment (CVI). A retrospective review of case records of all children aged visual impairment was seen in 88.8%, and 11.2% had high functioning CVI. Fifty-eight (46.4%) patients had significant refractive errors, 40 (32.25%) had strabismus, 4 (3.2%) had visually significant cataract, and 40 (32%) had optic atrophy. Motor delay was observed in 39.5%, speech delay was evident in 22.4%, and cognitive delay in 16%. HIE is the most common cause (one-third) of CVI in our population, and the majority of them presented at age visual impairment (88.8%). A significant number of them have treatable ophthalmic conditions such as refractive errors (46.4%), accommodative insufficiency (12.1%), and cataract (3.2%), and more than one-third of them also have delay in other areas of development.

  5. Development of automatic extraction of the corpus callosum from magnetic resonance imaging of the head and examination of the early dementia objective diagnostic technique in feature analysis

    International Nuclear Information System (INIS)

    Kodama, Naoki; Kaneko, Tomoyuki

    2005-01-01

    We examined the objective diagnosis of dementia based on changes in the corpus callosum. We examined midsagittal head MR images of 17 early dementia patients (2 men and 15 women; mean age, 77.2±3.3 years) and 18 healthy elderly controls (2 men and 16 women; mean age, 73.8±6.5 years), 35 subjects altogether. First, the corpus callosum was automatically extracted from the MR images. Next, early dementia was compared with the healthy elderly individuals using 5 features of the straight-line methods, 5 features of the Run-Length Matrix, and 6 features of the Co-occurrence Matrix from the corpus callosum. Automatic extraction of the corpus callosum showed an accuracy rate of 84.1±3.7%. A statistically significant difference was found in 6 of the 16 features between early dementia patients and healthy elderly controls. Discriminant analysis using the 6 features demonstrated a sensitivity of 88.2% and specificity of 77.8%, with an overall accuracy of 82.9%. These results indicate that feature analysis based on changes in the corpus callosum can be used as an objective diagnostic technique for early dementia. (author)

  6. Practical X-ray diagnostics orthopedics and trauma surgery. Indication, adjustment technique and radiation protection; Praktische Roentgendiagnostik Orthopaedie und Unfallchirurgie. Indikation, Einstelltechnik, Strahlenschutz

    Energy Technology Data Exchange (ETDEWEB)

    Flechtenmacher, Johannes [Ortho-Zentrum am Ludwigsplatz, Karlsruhe (Germany); Sabo, Desiderius [Klinik St. Elisabeth, Heidelberg (Germany). Sportopaedic Heidelberg

    2014-07-01

    The book on X-ray diagnostics in orthopedics and trauma surgery includes the following chapters: 1. Introduction: radiation protection, equipment technology radiological diagnostics of skeleton carcinomas, specific aspects of trauma surgery, special aspects of skeleton radiology for children. 2. X-ray diagnostics of different anatomical regions: ankle joint, knee, hips and pelvis, hand and wrist joint, elbow, shoulder, spinal cord. 3. Appendix: radiation protection according to the X-ray regulations.

  7. Ophthalmology on social networking sites: an observational study of Facebook, Twitter, and LinkedIn.

    Science.gov (United States)

    Micieli, Jonathan A; Tsui, Edmund

    2015-01-01

    The use of social media in ophthalmology remains largely unknown. Our aim was to evaluate the extent and involvement of ophthalmology journals, professional associations, trade publications, and patient advocacy and fundraising groups on social networking sites. An archived list of 107 ophthalmology journals from SCImago, trade publications, professional ophthalmology associations, and patient advocacy organizations were searched for their presence on Facebook, Twitter, and LinkedIn. Activity and popularity of each account was quantified by using the number of "likes" on Facebook, the number of followers on Twitter, and members on LinkedIn. Of the 107 journals ranked by SCImago, 21.5% were present on Facebook and 18.7% were present on Twitter. Journal of Community Eye Health was the most popular on Facebook and JAMA Ophthalmology was most popular on Twitter. Among the 133 members of the International Council of Ophthalmology, 17.3% were present on Facebook, 12.8% were present on Twitter, and 7.5% were present on LinkedIn. The most popular on Facebook was the International Council of Ophthalmology, and the American Academy of Ophthalmology was most popular on Twitter and LinkedIn. Patient advocacy organizations were more popular on all sites compared with journals, professional association, and trade publications. Among the top ten most popular pages in each category, patient advocacy groups were most active followed by trade publications, professional associations, and journals. Patient advocacy groups lead the way in social networking followed by professional organizations and journals. Although some journals use social media, most have yet to engage its full potential and maximize the number of potential interested individuals.

  8. Communication Skills Training in Ophthalmology: Results of a Needs Assessment and Pilot Training Program.

    Science.gov (United States)

    Mishra, Anuradha; Browning, David; Haviland, Miriam J; Jackson, Mary Lou; Luff, Donna; Meyer, Elaine C; Talcott, Katherine; Kloek, Carolyn E

    To conduct a needs assessment to identify gaps in communication skills training in ophthalmology residency programs and to use these results to pilot a communication workshop that prepares residents for difficult conversations. A mixed-methods design was used to perform the needs assessment. A pre-and postsurvey was administered to workshop participants. Mass Eye and Ear Infirmary, Harvard Medical School (HMS), Department of Ophthalmology. HMS ophthalmology residents from postgraduate years 2-4 participated in the needs assessment and the workshop. Ophthalmology residency program directors in the United States participated in national needs assessment. Ophthalmology program directors across the United States were queried on their perception of resident communication skills training through an online survey. A targeted needs assessment in the form of a narrative exercise captured resident perspectives on communication in ophthalmology from HMS residents. A group of HMS residents participated in the pilot workshop and a pre- and postsurvey was administered to participants to assess its effectiveness. The survey of program directors yielded a response rate of 40%. Ninety percent of respondents agreed that the communication skills training in their programs could be improved. Fifteen of 24 residents (62%) completed the needs assessment. Qualitative analysis of the narrative material revealed four themes; (1) differing expectations, (2) work role and environment, (3) challenges specific to ophthalmology, and (4) successful strategies adopted. Nine residents participated in the workshop. There was a significant improvement post-workshop in resident reported scores on their ability to manage their emotions during difficult conversations (p = 0.03). There is an opportunity to improve communication skills training in ophthalmology residency through formalized curriculum. Copyright © 2017 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights

  9. Diagnostic Development on NSTX

    International Nuclear Information System (INIS)

    A.L. Roquemore; D. Johnson; R. Kaita; et al

    1999-01-01

    Diagnostics are described which are currently installed or under active development for the newly commissioned NSTX device. The low aspect ratio (R/a less than or equal to 1.3) and low toroidal field (0.1-0.3T) used in this device dictate adaptations in many standard diagnostic techniques. Technical summaries of each diagnostic are given, and adaptations, where significant, are highlighted

  10. VALUE-BASED MEDICINE AND OPHTHALMOLOGY: AN APPRAISAL OF COST-UTILITY ANALYSES

    Science.gov (United States)

    Brown, Gary C; Brown, Melissa M; Sharma, Sanjay; Brown, Heidi; Smithen, Lindsay; Leeser, David B; Beauchamp, George

    2004-01-01

    ABSTRACT Purpose To ascertain the extent to which ophthalmologic interventions have been evaluated in value-based medicine format. Methods Retrospective literature review. Papers in the healthcare literature utilizing cost-utility analysis were reviewed by researchers at the Center for Value-Based Medicine, Flourtown, Pennsylvania. A literature review of papers addressing the cost-utility analysis of ophthalmologic procedures in the United States over a 12-year period from 1992 to 2003 was undertaken using the National Library of Medicine and EMBASE databases. The cost-utility of ophthalmologic interventions in inflation-adjusted (real) year 2003 US dollars expended per quality-adjusted life-year ($/QALY) was ascertained in all instances. Results A total of 19 papers were found, including a total of 25 interventions. The median cost-utility of ophthalmologic interventions was $5,219/QALY, with a range from $746/QALY to $6.5 million/QALY. Conclusions The majority of ophthalmologic interventions are especially cost-effective by conventional standards. This is because of the substantial value that ophthalmologic interventions confer to patients with eye diseases for the resources expended. PMID:15747756

  11. Guiding role of typical cases in clinical training for ophthalmology professional degree graduate students

    Directory of Open Access Journals (Sweden)

    Zhe Wang

    2014-05-01

    Full Text Available With the change of the concept of graduate enrollment, the recruiting proportion of clinical medicine professional degree graduate students is more and more, and the training of professional degree graduate students is increasingly focusing on practical. In our experience in clinical training for ophthalmology professional degree graduate students, increasing the ward clinical practice time is important. For particular emphasis on the guiding role of the typical cases, each professional group combined their professional characteristics of the typical cases to instruct the graduate students, training their clinical diagnosis and treatment ability, training their microsurgical techniques. From clinical medical writing, record summary, literature review, professional degree graduate students could expand their knowledge structure, practice their thesis writing ability. Based on the typical cases, expansion of knowledge coverage, they could improve the ability of diagnosis and treatment for special disease cases. In this rigorous training system, professional degree graduate students can learn by analogy, and focus on typical cases to get the most intuitive panoramic understanding of the diseases, with a minimum of time to master the most clinical knowledge, to enrich clinical experience, and to lay the foundation for future work in the assessment.

  12. Ophthalmology in North America: Early Stories (1491-1801

    Directory of Open Access Journals (Sweden)

    Christopher T Leffler

    2017-07-01

    Full Text Available New World plants, such as tobacco, tomato, and chili, were held to have beneficial effects on the eyes. Indigenous healers rubbed or scraped the eyes or eyelids to treat inflammation, corneal opacities, and even eye irritation from smoke. European settlers used harsh treatments, such as bleeding and blistering, when the eyes were inflamed or had loss of vision with a normal appearance (gutta serena. In New Spain, surgery for corneal opacity was performed in 1601 and cataract couching in 1611. North American physicians knew of contralateral loss of vision after trauma or surgery (sympathetic ophthalmia, which they called “sympathy.” To date, the earliest identified cataract couching by a surgeon trained in the New World was performed in 1769 by John Bartlett of Rhode Island. The American Revolution negatively affected ophthalmology, as loyalist surgeons were expelled and others were consumed with wartime activities. After the war, cataract extraction was imported to America in earnest and academic development resumed. Charles F Bartlett, the son of John, performed cataract extraction but was also a “rapacious privateer.” In 1801, a doctor in the frontier territory of Kentucky observed anticholinergic poisoning by Datura stramonium (Jimsonweed and suggested that this agent be applied topically to dilate the pupil before cataract extraction. John Warren at Harvard preferred couching in the 1790s, but, after his son returned from European training, recommended treating angle closure glaucoma by lens extraction. Other eye procedures described or advertised in America before the 19th century included enucleation, resection of conjunctival lesions or periocular tumors, treatment of lacrimal fistula, and fitting of prosthetic eyes.

  13. Application of traditional indexes and adverse events in the ophthalmologic perioperative medical quality evaluation during 2010-2012

    Directory of Open Access Journals (Sweden)

    Yong-Na Bian

    2015-10-01

    Full Text Available AIM: To evaluate the medical quality of ophthalmologic perioperative period during 2010-2012 in our hospital.METHODS:The relevant data of perioperative period were collected in our hospital during 2010-2012, and the medical quality of perioperative period was evaluated by using the traditional evaluation indexes and adverse events. Whereby, the traditional indicators include vision changes, improving of intraocular pressure, diagnostic accordance rate before and after operation, cure improvement rate, successful rescue rate, and incidence of surgical complications, etc. Adverse events are associated with ophthalmologic perioperative events including pressure sores, postoperative wound infection, drug adverse events, and equipment related adverse events.RESULTS:There were 1483, 1662 and 1931 ophthalmic operations in our hospital in the year 2010, 2011 and 2012, respectively. From traditional index analysis, the proportions of vision improvement for each year were 96.43%, 96.76% and 97.32%, respectively; the rates of intraocular pressure improvement were 87.50%, 85.72% and 90.17%, respectively (P <0.05; the diagnostic accordance rates before and after operation were 99.86%, 99.94% and 99.90%, respectively; cure improvement rates were 99.73%, 99.93% and 99.84%, respectively; the successful rescue rates were 82.98%, 81.46% and 76.66%, respectively; the complications incidence rates were 18.44%, 17.52% and 17.97%, respectively. The negative factor analysis results showed that:among all the patients of ophthalmic surgeries in our hospital during 2010 and 2012, only one case of postoperative wound infection was found in 2011, and also only one case of tumbling in 2010. The adverse drug events for each year were 1 case (0.07%, 2 cases (0.12%, and 4 cases (0.21%, respectively; the medical device adverse events for each year were 3 cases (0.20%, 5 cases (0.30%, and 6 cases (0.31%, respectively. Noticeably, only one case with postoperative infection of

  14. A Comprehensive Proteomics Analysis of the Human Iris Tissue: Ready to Embrace Postgenomics Precision Medicine in Ophthalmology?

    Science.gov (United States)

    Murthy, Krishna R; Dammalli, Manjunath; Pinto, Sneha M; Murthy, Kalpana Babu; Nirujogi, Raja Sekhar; Madugundu, Anil K; Dey, Gourav; Subbannayya, Yashwanth; Mishra, Uttam Kumar; Nair, Bipin; Gowda, Harsha; Prasad, T S Keshava

    2016-09-01

    The annual economic burden of visual disorders in the United States was estimated at $139 billion. Ophthalmology is therefore one of the salient application fields of postgenomics biotechnologies such as proteomics in the pursuit of global precision medicine. Interestingly, the protein composition of the human iris tissue still remains largely unexplored. In this context, the uveal tract constitutes the vascular middle coat of the eye and is formed by the choroid, ciliary body, and iris. The iris forms the anterior most part of the uvea. It is a thin muscular diaphragm with a central perforation called pupil. Inflammation of the uvea is termed uveitis and causes reduced vision or blindness. However, the pathogenesis of the spectrum of diseases causing uveitis is still not very well understood. We investigated the proteome of the iris tissue harvested from healthy donor eyes that were enucleated within 6 h of death using high-resolution Fourier transform mass spectrometry. A total of 4959 nonredundant proteins were identified in the human iris, which included proteins involved in signaling, cell communication, metabolism, immune response, and transport. This study is the first attempt to comprehensively profile the global proteome of the human iris tissue and, thus, offers the potential to facilitate biomedical research into pathological diseases of the uvea such as Behcet's disease, Vogt Koyonagi Harada's disease, and juvenile rheumatoid arthritis. Finally, we make a call to the broader visual health and ophthalmology community that proteomics offers a veritable prospect to obtain a systems scale, functional, and dynamic picture of the eye tissue in health and disease. This knowledge is ultimately pertinent for precision medicine diagnostics and therapeutics innovation to address the pressing needs of the 21st century visual health.

  15. Perspective of ophthalmology residents in the United States about residency programs and competency in relation to the International Council of Ophthalmology guidelines.

    Science.gov (United States)

    Abdelfattah, Nizar Saleh; Radwan, Ahmed E; Sadda, Srinivas R

    2016-09-01

    To evaluate the perspective of ophthalmology residents in the US about their residency programs and compare the competency of residency programs to international competency levels set by the International Council of Ophthalmology (ICO). A cross-sectional web-based survey extracted from the ICO published competency standards was sent to program directors of ophthalmology residency programs in the US to forward it to current PGY-3, 4 residents, and residency graduates from 2011 to 2014. Eighty-seven responses were received, comprising 61 residents and 26 graduates. Most respondents were highly satisfied with their programs (93.6%). Clinic-based training was rated satisfactorily. Insufficient exposure to low-vision rehabilitation (38.5%), refraction and contact lenses prescription (38.5%), and vitreo-retinal surgeries (38.5%) was reported. Respondents were satisfied with their overall surgical experiences, with the vast majority (>83%) rating case volume, complexity, and variety as satisfactory or better. A significant group stated they had insufficient exposure to extra-capsular cataract extraction (26.3%), refractive surgery (19.7%), and orbital surgery (64.5%). All graduates surveyed passed their Ophthalmic Knowledge Assessment Program (OKAP) examinations, and 72% felt their residency programs adequately prepared them for the examinations. All respondents reported insufficient training in certain nonclinical areas, such as practice management, staffing, and administration skills. Ophthalmology residents in the US express high levels of satisfaction with their residency training programs. While most programs adequately address most ICO core objectives, certain curriculum modifications should be considered.

  16. Use of sting-response techniques for simulate diagnostics in human esophagus; Uso de tecnicas estimulo-respuesta para simular diagnosticos en esofago humano

    Energy Technology Data Exchange (ETDEWEB)

    Rodriguez, I.; Gonzalez, Y.; Valdes, L.; Alfonso, J.A.; Estevez, E. [Facultad de Quimica Farmacia, Universidad Central de Las Villas (Cuba)

    2003-07-01

    In this work a study of simulation of the gamma graphic studies that are carried out in human esophagus in the Dept. of Nuclear Medicine of the 'Celestino Hernandez Robau Hospital of Santa Clara is presented. For the investigation tubular reactors were used and sting-response techniques with radioactive tracer of Technetium 99 metastable to a concentration of 1 mCi and several flows were applied. The distribution curves of residences times were obtained, those that respond to an equation of the type: Y = A + B exp (- exp((x-C)/D)) - ((x-C/D)+1). They were also carried out, optimizations studies of the doses of the radioactive to give to the patients from 1 mCi (that is the one used in studies) up to 0,5 mCi, and the influences on the obtained distributions of residence time were analyzed. It was confirmed the possibility to lower the doses with clear information of the signal. It was also carried out a simulation of the attenuation of the radiations that takes place in the patients by the interposition of tissues among the analyzed organ, and the detection equipment. It was used paraffin for tissue simulation. It was found the almost independence of the intensity of the radiations with the thickness, for the assayed doses. Lastly it was found a complex mathematical model that responds to the diagnostic curves obtained in these studies, being correlated the coefficients of the pattern with the most important physical parameters of the system, giving it a practical and useful value, all time that the error among the values that this it predicts and the experimental ones do not surpass of 5%. (Author)

  17. Taenia solium porcine cysticercosis in Madagascar: Comparison of immuno-diagnostic techniques and estimation of the prevalence in pork carcasses traded in Antananarivo city.

    Science.gov (United States)

    Porphyre, V; Betson, M; Rabezanahary, H; Mboussou, Y; Zafindraibe, N J; Rasamoelina-Andriamanivo, H; Costard, S; Pfeiffer, D U; Michault, A

    2016-03-30

    Taenia solium cysticercosis was reported in official veterinary and medical statistics to be highly prevalent in pigs and humans in Madagascar, but few estimates are available for pigs. This study aimed to estimate the seroprevalence of porcine cysticercosis among pigs slaughtered in Antananarivo abattoirs. Firstly, the diagnostic performance of two antigen-ELISA techniques (B158B60 Ag-ELISA and HP10 Ag-ELISA) and an immunoblotting method were compared with meat inspection procedures on a sample of pigs suspected to be infected with (group 1; n=250) or free of (group 2; n=250) T. solium based on direct veterinary inspection in Madagascar. Sensitivity and specificity of the antigen ELISAs were then estimated using a Bayesian approach for detection of porcine cysticercosis in the absence of a gold standard. Then, a third set of pig sera (group 3, n=250) was randomly collected in Antananarivo slaughterhouses and tested to estimate the overall prevalence of T. solium contamination in pork meat traded in Antananarivo. The antigen ELISAs showed a high sensitivity (>84%), but the B158B60 Ag-ELISA appeared to be more specific than the HP10 Ag-ELISA (model 1: 95% vs 74%; model 2: 87% vs 71%). The overall prevalence of porcine cysticercosis in Antananarivo slaughterhouses was estimated at 2.3% (95% credibility interval [95%CrI]: 0.09-9.1%) to 2.6% (95%CrI: 0.1-10.3%) depending on the model and priors used. Since the sample used in this study is not representative of the national pig population, village-based surveys and longitudinal monitoring at slaughter are needed to better estimate the overall prevalence, geographical patterns and main risk factors for T. solium contamination, in order to improve control policies. Copyright © 2015 Elsevier B.V. All rights reserved.

  18. Molecular characterization of the rDNA-ITS sequence and a PCR diagnostic technique for Pileolaria terebinthi, the cause of pistachio rust

    Directory of Open Access Journals (Sweden)

    Hossein ALAEI

    2013-01-01

    Full Text Available Eleven samples of the most important pistachio rust (caused by Pileolaria terebinthi (DC. Cast.,, which causes disease on Beneh (Pistacia atlantica Desf. subsp. mutica (Fisch. & Mey. Rech. F and Kasoor (Pistacia khinjuk Stocks., were collected from herbarium specimens and pistachio fields at the Pistachio Research Institute in Rafsanjan, Iran. The complete sequences of ribosomal DNA internal transcribed spacers ITS1 and ITS2 (rDNA ITS from the samples were determined and analysed. In general, very little rDNA ITS sequence variation was observed between rDNA ITS sequences of P. terebinthi samples. The length of the PCR fragments was 621 bp (for ITS1F-ITS4 and 1177 bp (for ITS1F-rust1, and consisted of 67 bp at the 3 ́ end of 18S rDNA, 93 bp of ITS1 region, 154 bp of 5.8S rDNA, 246 bp of the ITS2 region, 57 bp (for ITS1F-ITS4 and 613 bp (for ITS1F-rust1 at the 5 ́ end of the 28S rDNA. Restriction fragment length polymorphisms (RFLPs of the rDNA-ITS region were used to identify Pileolaria terebinthi. Three strong bands of 105, 134 and 381 bp and five bands of 105, 134, 200, 301 and 437 bp are observed for the fragment of “ITS1F-ITS4” and “ITS1F-rust1”, respectively. A PCR-RFLP diagnostic technique provided effective identification of the species by a unique pattern with the specific restriction enzyme XapI (ApoI.

  19. Molecular diagnostics of periodontitis

    OpenAIRE

    Izabela Korona-Głowniak; Radosław Siwiec; Marcin Berger; Anna Malm; Jolanta Szymańska

    2017-01-01

    The microorganisms that form dental plaque are the main cause of periodontitis. Their identification and the understanding of the complex relationships and interactions that involve these microorganisms, environmental factors and the host’s health status enable improvement in diagnostics and targeted therapy in patients with periodontitis. To this end, molecular diagnostics techniques (both techniques based on the polymerase chain reaction and those involving nucleic acid analysis via hybridi...

  20. Prototype Development: Context-Driven Dynamic XML Ophthalmologic Data Capture Application.

    Science.gov (United States)

    Peissig, Peggy; Schwei, Kelsey M; Kadolph, Christopher; Finamore, Joseph; Cancel, Efrain; McCarty, Catherine A; Okorie, Asha; Thomas, Kate L; Allen Pacheco, Jennifer; Pathak, Jyotishman; Ellis, Stephen B; Denny, Joshua C; Rasmussen, Luke V; Tromp, Gerard; Williams, Marc S; Vrabec, Tamara R; Brilliant, Murray H

    2017-09-13

    The capture and integration of structured ophthalmologic data into electronic health records (EHRs) has historically been a challenge. However, the importance of this activity for patient care and research is critical. The purpose of this study was to develop a prototype of a context-driven dynamic extensible markup language (XML) ophthalmologic data capture application for research and clinical care that could be easily integrated into an EHR system. Stakeholders in the medical, research, and informatics fields were interviewed and surveyed to determine data and system requirements for ophthalmologic data capture. On the basis of these requirements, an ophthalmology data capture application was developed to collect and store discrete data elements with important graphical information. The context-driven data entry application supports several features, including ink-over drawing capability for documenting eye abnormalities, context-based Web controls that guide data entry based on preestablished dependencies, and an adaptable database or XML schema that stores Web form specifications and allows for immediate changes in form layout or content. The application utilizes Web services to enable data integration with a variety of EHRs for retrieval and storage of patient data. This paper describes the development process used to create a context-driven dynamic XML data capture application for optometry and ophthalmology. The list of ophthalmologic data elements identified as important for care and research can be used as a baseline list for future ophthalmologic data collection activities. ©Peggy Peissig, Kelsey M Schwei, Christopher Kadolph, Joseph Finamore, Efrain Cancel, Catherine A McCarty, Asha Okorie, Kate L Thomas, Jennifer Allen Pacheco, Jyotishman Pathak, Stephen B Ellis, Joshua C Denny, Luke V Rasmussen, Gerard Tromp, Marc S Williams, Tamara R Vrabec, Murray H Brilliant. Originally published in JMIR Medical Informatics (http://medinform.jmir.org), 13.09.2017.

  1. Plasma diagnostics for tokamaks and stellarators

    Energy Technology Data Exchange (ETDEWEB)

    Stott, P E; Sanchez, J

    1994-07-01

    A collection of papers on plasma diagnostics is presented. The papers show the state of the art developments in a series of techniques: Magnetic diagnostics, Edge diagnostics, Langmuir probes, Spectroscopy, Microwave and FIR diagnostics as well as Thomson Scattering. Special interest was focused on those diagnostics oriented to fluctuations measurements in the plasma. (Author) 451 refs.

  2. Plasma diagnostics for tokamaks and stellarators

    International Nuclear Information System (INIS)

    Stott, P.E.; Sanchez, J.

    1994-01-01

    A collection of papers on plasma diagnostics is presented. The papers show the state of the art developments in a series of techniques: magnetic diagnostics, Edge diagnostics, Langmuir probes, Spectroscopy, Microwave and FIR diagnostics as well as Thomson Sattering. Special interest was focused on those diagnostics oriented to fluctuations measurements in the plasma

  3. Representation of Women With Industry Ties in Ophthalmology.

    Science.gov (United States)

    Reddy, Ashvini K; Bounds, Gregory W; Bakri, Sophie J; Gordon, Lynn K; Smith, Justine R; Haller, Julia A; Thorne, Jennifer E

    2016-06-01

    Women in ophthalmology are growing in number and have made strides in traditional metrics of professional achievement. Professional ties to industry represent another potential means of career advancement, recognition, and income. To report the representation of women among ophthalmologists receiving industry remuneration for research, consulting, honoraria, grants, royalties, and faculty/speaker roles. In this observational, retrospective study, the Centers for Medicare and Medicaid Services Open Payments database for payments to ophthalmologists by biomedical companies was reviewed for representation, median payments, and mean payments by women and men for industry relationships in 2013 and 2014. The analysis was performed from July 2015 to November 2015. The primary outcome measures were percentage representation of women vs men overall and in industry research, consulting, speaking roles, royalties and licenses, grants, services other than consulting, and honoraria. Secondary outcome measures included mean and median payments from industry to female vs male ophthalmologists. In 2013, 4164 of 21 380 (19.5%) ophthalmologists were women, and of 1204 ophthalmologists analyzed for industry payments, 176 (4.2%) women had industry ties compared with 1028 (6%) men (P women were $11 419 compared with $20 957 for men (P = .001), and median payments to women were $3000 compared with $4787 for men (P = .007). In 2013, women were underrepresented among ophthalmologists receiving industry payments for research (49 of 462 [10.6%]), consulting (96 of 610 [15.7%]), honoraria (3 of 47 [6.4%]), industry grants (1 of 7 [14.3%]), royalties and licenses (1 of 13 [7.7%]), and faculty/speaker roles (2 of 48 [4.2%]). In 2014, 4352 of 21 531 (20.2%) of ophthalmologists were women. Of 1518 ophthalmologists analyzed for industry payments, 255 (6%) women had industry ties compared with 1263 (7.4%) men (P women were $14 848 compared with $30 513 for men (P = .004

  4. Relocation consequences on an ophthalmology consultation service from an inpatient to outpatient facility

    Directory of Open Access Journals (Sweden)

    Singh JS

    2015-10-01

    Full Text Available Jorawer S Singh,1 Vincent M Imbrogno,2 Mary K Howard,3 Amandip S Cheema,3 Ausra D Selvadurai,4 Surbhi Bansal5 1Department of Ophthalmology, George Washington University, Washington, DC, 2Contemporary Ophthalmology of Erie, Erie, PA, 3Department of Ophthalmology, University at Buffalo, Buffalo, NY, 4OcuSight Eye Care Center, Rochester, NY, 5Department of Ophthalmology, Virginia Commonwealth University, Richmond, VA, USA Importance: This study shows that relocation of an academic ophthalmology residency program from an inpatient to an outpatient setting in western New York does not affect the consult volume but affects management patterns and follow-up rates.Objective: To investigate the effects on the ophthalmology consultation service of an academic program with relocation from a Regional Level-1 Trauma center to an outpatient facility.Design: Consultation notes from 3 years before and 3 years after the University at Buffalo’s (UB Department of Ophthalmology relocation from a Regional Level-1 Trauma center (Erie County Medical Center to an outpatient facility (Ross Eye Institute were obtained from hospital electronic medical records and analyzed.Setting: Hospitalized care and institutional practice.Participants: All inpatient or Emergency Room Ophthalmology consultation patients from the Department of Ophthalmology at UB from 2004 to 2010 (1,379 patients.Exposures: None, this was a retrospective chart review.Main outcome measures: Patient demographics, reason for consult, diagnoses, and ophthalmic procedures performed by the UB Department of Ophthalmology before and after its relocation.Results: Relocation to the outpatient facility did not affect consult volume (P=0.15. The number of consults focusing on ophthalmic conditions, as a percentage of the yearly total, rose 460% (P=0.0001, while systemic condition consults with ocular manifestations fell 83% (P=0.0001. Consults for ocular trauma decreased 65% (P=0.0034. Consults ending with a

  5. Trends in Authorship of Articles in Major Ophthalmology Journals by Gender, 2002-2014.

    Science.gov (United States)

    Mimouni, Michael; Zayit-Soudry, Shiri; Segal, Ori; Barak, Yoreh; Nemet, Arie Y; Shulman, Shiri; Geffen, Noa

    2016-08-01

    To evaluate trends in the prevalence of women authors in ophthalmology in recent years. Cohort study. Authors listed in publications of 6 leading ophthalmology journals between January 2002 and December 2014. Using the PubMed search engine, we conducted an observational study of trends in gender distribution of all authors in 6 leading ophthalmology journals between January 2002 and December 2014. In multiauthored articles, the first listed author often is the lead investigator and the last author is the senior author. Therefore, the full names and positions (first, middle, or last) of all authors in every article were collected. A Google-based name identifier was used to assign the gender of authors. Proportion of women authors throughout the study period in all journals, general ophthalmology versus subspecialty journals, and basic science versus clinical research journals. Furthermore, we assessed the proportion of women in different authorship positions (first, middle, and last). A total of 102 254 authors from 23 026 published articles were analyzed. There was a significant rise over time in the percentage of women authors, with a steeper slope for first authors than for last authors (P<0.001), although in 2014, women authors were less than the 50% mark in all categories of authorship. The rise in the percentage of women authors was similar in basic and clinical research, but was steeper for first authorship than for last authorship (P<0.001). In all 3 authorship positions (first, middle, or last), women's contributions consistently were higher in basic research publications. The rise in the percentage of women authors was significantly steeper for general journals than for subspecialty journals (P<0.001). There was no significant rise for last authorship in subspecialty journals. In all 3 authorship positions, the proportion of women was consistently higher in general ophthalmology journals than for subspecialty journals. Despite an overall increase in

  6. Attitudes to research and research training among ophthalmologists and ophthalmology trainees in New Zealand.

    Science.gov (United States)

    Jayasundera, Thiran; Fisk, Michael; McGhee, Charles N J

    2003-08-01

    To determine the attitudes to research and research training among ophthalmologists and ophthalmology trainees in New Zealand. A structured, self-administered questionnaire was devised and after preliminary validation a postal survey was sent to all ophthalmologists and ophthalmology registrars and fellows in New Zealand. A total of 82 replies were received from 115 questionnaires sent out; a response rate of 71.3%. An overwhelming majority found research to have benefited their education, clinical practice and career; 67.1% of the respondents intended to do research in the future. Although a majority (56.4%) felt research to be beneficial to ophthalmology training, 42.3% felt research would be of limited or no benefit when selecting candidates for vocational training. However, 97.5% of respondents felt that ophthalmology trainees should undertake some form of research during training, with most supporting small studies or case reports (44.4%) or a short structured training course in research (42.0%). Interestingly, 86.6% felt that research methodology and data analysis should be taught in a structured fashion with most supporting courses or seminars of a few weeks duration during the vocational training period. Many ophthalmologists felt inadequately equipped or trained to mentor and supervise trainees undertaking research and 41.5% of consultant ophthalmologists felt further training to fulfil this role would be beneficial. This survey suggests that New Zealand ophthalmologists generally approve of and support a place for research, possibly of a more structured design, during ophthalmology training.

  7. Narrowing of the Diagnostic Gap of Acute Gastroenteritis in Children 0-6 Years of Age Using a Combination of Classical and Molecular Techniques, Delivers Challenges in Syndromic Approach Diagnostics.

    Science.gov (United States)

    Steyer, Andrej; Jevšnik, Monika; Petrovec, Miroslav; Pokorn, Marko; Grosek, Štefan; Fratnik Steyer, Adela; Šoba, Barbara; Uršič, Tina; Cerar Kišek, Tjaša; Kolenc, Marko; Trkov, Marija; Šparl, Petra; Duraisamy, Raja; Lipkin, W Ian; Terzić, Sara; Kolnik, Mojca; Mrvič, Tatjana; Kapoor, Amit; Strle, Franc

    2016-09-01

    Twenty-five percent to 50% of acute gastroenteritis (AGE) cases remain etiologically undiagnosed. Our main aim was to determine the most appropriate list of enteric pathogens to be included in the daily diagnostics scheme of AGE, ensuring the lowest possible diagnostic gap. Two hundred ninety seven children ≤6 years of age, admitted to hospital in Slovenia, October 2011 to October 2012, with AGE, and 88 ≤6 years old healthy children were included in the study. A broad spectrum of enteric pathogens was targeted with molecular methods, including 8 viruses, 6 bacteria and 2 parasites. At least one enteric pathogen was detected in 91.2% of cases with AGE and 27.3% of controls. Viruses were the most prevalent (82.5% and 15.9%), followed by bacteria (27.3% and 10.2%) and parasites (3.0% and 1.1%) in cases and controls, respectively. A high proportion (41.8%) of mixed infections was observed in the cases. For cases with undetermined etiology (8.8%), stool samples were analyzed with next generation sequencing, and a potential viral pathogen was detected in 17 additional samples (5.8%). Our study suggests that tests for rotaviruses, noroviruses genogroup II, adenoviruses 40/41, astroviruses, Campylobacter spp. and Salmonella sp. should be included in the initial diagnostic algorithm, which revealed the etiology in 83.5% of children tested. The use of molecular methods in diagnostics of gastroenteritis is preferable because of their high sensitivity, specificity, fast performance and the possibility of establishing the concentration of the target. The latter may be valuable for assessing the clinical significance of the detected enteric, particularly viral pathogens.

  8. [Evaluation of Web-based software applications for administrating and organising an ophthalmological clinical trial site].

    Science.gov (United States)

    Kortüm, K; Reznicek, L; Leicht, S; Ulbig, M; Wolf, A

    2013-07-01

    The importance and complexity of clinical trials is continuously increasing, especially in innovative specialties like ophthalmology. Therefore an efficient clinical trial site organisational structure is essential. In modern internet times, this can be accomplished by web-based applications. In total, 3 software applications (Vibe on Prem, Sharepoint and open source software) were evaluated in a clinical trial site in ophthalmology. Assessment criteria were set; they were: reliability, easiness of administration, usability, scheduling, task list, knowledge management, operating costs and worldwide availability. Vibe on Prem customised by the local university met the assessment criteria best. Other applications were not as strong. By introducing a web-based application for administrating and organising an ophthalmological trial site, studies can be conducted in a more efficient and reliable manner. Georg Thieme Verlag KG Stuttgart · New York.

  9. Ophthalmologic Disease in HIV Infection: Recent Changes in Pathophysiology and Treatment.

    Science.gov (United States)

    Stewart, Michael W

    2017-10-19

    Ophthalmologic conditions were among the earliest described findings in patients with the acquired immunodeficiency syndrome (AIDS). The purpose of this review is to highlight recent changes in the pathophysiology and management of ophthalmologic conditions in patients infected with the human immunodeficiency virus (HIV). The introduction of highly active antiretroviral therapy (HAART) in 1996 changed ophthalmologic findings from predominantly acute infectious diseases to chronic, slowly progressive, debilitating conditions. HIV-associated neuroretinal disorder infrequently leads to blindness, but it causes visual disability in a large percentage of patients. Cytomegalovirus retinitis is now seen less commonly in the USA, but it remains an important cause of blindness in HIV-infected patients from developing countries. Immune recovery uveitis has emerged as a major cause of visual disability in the USA. As HIV has become a chronic disease, visual disability due to chronic noninfectious diseases have become increasingly important.

  10. Career choices for ophthalmology made by newly qualified doctors in the United Kingdom, 1974–2005

    Directory of Open Access Journals (Sweden)

    Goldacre Michael J

    2008-03-01

    Full Text Available Abstract Background The paper aims to report trends in career choices for ophthalmology among UK medical graduates. Methods Postal questionnaire surveys were undertaken of qualifiers from all UK medical schools in nine qualification years since 1974. Data were analysed by univariate cross-tabulation. The significance of comparisons between groups of doctors were calculated by the use of chi-squared tests and adjusted residuals. Results Ophthalmology was the first choice of long term career for 2.3% of men and 1.5% of women one year after qualification; 2.0% of men and 1.4% of women three years after; and 1.8% of men and 1.2% of women at five years. Comparing early choices with eventual destinations, 64% who chose ophthalmology in year one, 84% in year three, and 92% in year five eventually practised in the specialty. The concordance between year one choice and eventual destination was higher for ophthalmology than for most other specialties. 'Enthusiasm for and commitment to the specialty' was the most important single factor in influencing career choice. The prospect of good working hours and conditions was also an important influence: it influenced career choice a great deal for a higher percentage of those who chose ophthalmology (66% in the third year than those who made other surgical choices (23%. Conclusion Those choosing ophthalmology show a high level of commitment to it. Their commitment is strengthened by the prospect of attractive hours and working conditions. Many doctors who become ophthalmologists have already made their choice by the end of their first post-qualification year.

  11. Effectiveness of a 40-minute Ophthalmologic Examination Teaching Session on Medical Student Learning

    Directory of Open Access Journals (Sweden)

    Wirachin Hoonpongsimanont

    2015-10-01

    Full Text Available Introduction: Emergency physicians are among the few specialists besides ophthalmologists who commonly perform ophthalmologic examinations using the slit lamp and other instruments. However, most medical schools in the United States do not require an ophthalmology rotation upon completion. Teaching procedural skills to medical students can be challenging due to limited resources and instructor availability. Our study assesses the effectiveness of a 40-minute hands-on teaching session on ophthalmologic examination for medical students using only two instructors and low-cost equipment. Methods: We performed an interventional study using a convenience sample of subjects. Pre- and post-workshop questionnaires on students’ confidence in performing ophthalmologic examination were administered. We used a paired t-test and Wilcoxon rank test to analyze the data. Results: Of the 30 participants in the study, the mean age was 25 and the majority were first-year medical students. The students’ confidence in performing every portion of the ophthalmologic exam increased significantly after the teaching session. We found that the average confidence level before the teaching session were below 2 on a 1-5 Likert scale (1 being the least confident. Confidence levels in using the slit lamp had the highest improvement among the skills taught (2.17 95% CI [1.84-2.49]. Students reported the least improvement in their confidence in assessing extraocular movements (0.73, 95% CI [0.30-1.71] and examining pupillary function (0.73, 95% CI [0.42-1.04]. We observed the biggest difference in median confidence level in the use of the tonometer (4 with a p-value of <0.05. Conclusion: A 40-minute structured hands-on training session can significantly improve students’ confidence levels in ophthalmologic skills.

  12. Flowfield modeling and diagnostics

    International Nuclear Information System (INIS)

    Gupta, A.K.; Lilley, D.G.

    1985-01-01

    This textbook is devoted solely to flowfield modeling and diagnostics; their practical use, recent and current research, and projected developments and trends. It provides an account of the use of a broad range of techniques in industrial and research practice, both with and without combustion. Application ideas are complemented by details about experimental and modeling techniques

  13. Dr Adam Zamenhof (1888-1940) and his insight into ophthalmology.

    Science.gov (United States)

    Wincewicz, Andrzej; Sulkowska, Mariola; Lieberman, E James; Bakunowicz-Lazarczyk, Alina; Sulkowski, Stanislaw

    2009-02-01

    Adam Zamenhof was greatly influenced by his father, Ludwik Zamenhof, who designed the international language Esperanto. Like his father, he became an ophthalmologist and joined the Esperanto movement. He published in the field of ophthalmology and was soon chosen as head of an ophthalmology department. He subsequently became Chief of the Orthodox Jewish Hospital at Czystem in Warsaw. He was active in the leadership of the Bialystok-Warsaw Chamber of Medical Doctors. He perished in the Nazi Holocaust (Shoah) but all Zamenhof's ideals that Adam served as a doctor and social activist remain still alive.

  14. Summary receiver operating characteristic curves as a technique for meta-analysis of the diagnostic performance of duplex ultrasonography in peripheral arterial disease

    NARCIS (Netherlands)

    deVries, SO; Hunink, MGM; Polak, JF

    Rationale and Objectives. We summarized and compared the diagnostic performance of duplex and color-guided duplex ultrasonography in the evaluation of peripheral arterial disease. We present our research as an example of the use of summary receiver operating characteristic (ROC) curves in a

  15. [Surgeon and eye doctor Caspar Stromayr and the ophthalmological illustrations in his "Practica copiosa" (1559)].

    Science.gov (United States)

    Nover, A; Kümmel, W F

    1984-11-01

    In 1559 Caspar Stromayr wrote a richly illustrated book about hernias and their treatment. The manuscript also includes 3 chapters of a book on ophthalmological diseases which, however, was never published. In addition, it contains 6 separate watercolor illustrations of eye diseases, though without any explanatory texts. The authors attempt to interpret these first colored pictures of eye diseases.

  16. Office-based deep sedation for pediatric ophthalmologic procedures using a sedation service model.

    Science.gov (United States)

    Lalwani, Kirk; Tomlinson, Matthew; Koh, Jeffrey; Wheeler, David

    2012-01-01

    Aims. (1) To assess the efficacy and safety of pediatric office-based sedation for ophthalmologic procedures using a pediatric sedation service model. (2) To assess the reduction in hospital charges of this model of care delivery compared to the operating room (OR) setting for similar procedures. Background. Sedation is used to facilitate pediatric procedures and to immobilize patients for imaging and examination. We believe that the pediatric sedation service model can be used to facilitate office-based deep sedation for brief ophthalmologic procedures and examinations. Methods. After IRB approval, all children who underwent office-based ophthalmologic procedures at our institution between January 1, 2000 and July 31, 2008 were identified using the sedation service database and the electronic health record. A comparison of hospital charges between similar procedures in the operating room was performed. Results. A total of 855 procedures were reviewed. Procedure completion rate was 100% (C.I. 99.62-100). There were no serious complications or unanticipated admissions. Our analysis showed a significant reduction in hospital charges (average of $1287 per patient) as a result of absent OR and recovery unit charges. Conclusions. Pediatric ophthalmologic minor procedures can be performed using a sedation service model with significant reductions in hospital charges.

  17. Office-Based Deep Sedation for Pediatric Ophthalmologic Procedures Using a Sedation Service Model

    Directory of Open Access Journals (Sweden)

    Kirk Lalwani

    2012-01-01

    Full Text Available Aims. (1 To assess the efficacy and safety of pediatric office-based sedation for ophthalmologic procedures using a pediatric sedation service model. (2 To assess the reduction in hospital charges of this model of care delivery compared to the operating room (OR setting for similar procedures. Background. Sedation is used to facilitate pediatric procedures and to immobilize patients for imaging and examination. We believe that the pediatric sedation service model can be used to facilitate office-based deep sedation for brief ophthalmologic procedures and examinations. Methods. After IRB approval, all children who underwent office-based ophthalmologic procedures at our institution between January 1, 2000 and July 31, 2008 were identified using the sedation service database and the electronic health record. A comparison of hospital charges between similar procedures in the operating room was performed. Results. A total of 855 procedures were reviewed. Procedure completion rate was 100% (C.I. 99.62–100. There were no serious complications or unanticipated admissions. Our analysis showed a significant reduction in hospital charges (average of $1287 per patient as a result of absent OR and recovery unit charges. Conclusions. Pediatric ophthalmologic minor procedures can be performed using a sedation service model with significant reductions in hospital charges.

  18. Electronic health record impact on productivity and efficiency in an academic pediatric ophthalmology practice.

    Science.gov (United States)

    Redd, Travis K; Read-Brown, Sarah; Choi, Dongseok; Yackel, Thomas R; Tu, Daniel C; Chiang, Michael F

    2014-12-01

    To measure the effect of electronic health record (EHR) implementation on productivity and efficiency in the pediatric ophthalmology division at an academic medical center. Four established providers were selected from the pediatric ophthalmology division at the Oregon Health & Science University Casey Eye Institute. Clinical volume was compared before and after EHR implementation for each provider. Time elapsed from chart open to completion (OTC time) and the proportion of charts completed during business hours were monitored for 3 years following implementation. Overall there was an 11% decrease in clinical volume following EHR implementation, which was not statistically significant (P = 0.18). The mean OTC time ranged from 5.5 to 28.3 hours among providers in this study, and trends over time were variable among the four providers. Forty-four percent of all charts were closed outside normal business hours (30% on weekdays, 14% on weekends). EHR implementation was associated with a negative impact on productivity and efficiency in our pediatric ophthalmology division. Copyright © 2014 American Association for Pediatric Ophthalmology and Strabismus. Published by Elsevier Inc. All rights reserved.

  19. The polaroid suppression test in a pediatric population with ophthalmologic disorders

    NARCIS (Netherlands)

    Pott, JWR; Kingma, C; Verhoeff, K; Grootendorst, RJ; de Faber, JTHN

    Purpose: The Polaroid suppression test (PST) is a new method for early detection of amblyogenic factors by screening for suppression. The apparatus can elicit suppression with the use of Polaroid filters. The aim of the present study was to examine a population of children with known ophthalmologic

  20. DIABETIC RETINOPATHY SCREENING THROUGH TELE-OPHTHALMOLOGY IN A PRIMARY CARE CENTER IN SOUTHERN BRAZIL.

    NARCIS (Netherlands)

    Rosses, Ana PO; Jornada Ben, A.; Souza, Camila Furtado de; Araújo, Aline Lutz de; Szortika, Adriana; Locatelli, Franciele; Carvalho, Gabriela de; Neumann, Cristina Rolim

    2015-01-01

    Diabetic retinopathy (DR) is a major cause of blindness and its prevalence varies between 15 and 20%. Brazilian people face limited access to ophthalmological services, so strategies in telemedicine to monitor retinal status may help to early diagnose patients developing DR. Objectives: To determine

  1. [Neuro-ophthalmology: the eye as a window to the brain].

    Science.gov (United States)

    Kesler, Anat

    2013-02-01

    Neuro-ophthalmology focuses on the diagnosis and treatment of visual disorders related to the neurological system rather than the globe itself. Being a subspecialty of both neurology and ophthalmology, it requires specialized training and expertise in diseases of the eye, brain, nerves and muscles. Commonly encountered pathologies in neuro-ophthalmology include: optic neuropathies (such as optic neuritis and ischemic optic neuropathy), visual field loss (transient, constant, unexplained), transient visual loss, unspecified visual disturbances, diplopia, abnormal eye movements, thyroid eye disease, myasthenia gravis, anisocoria, and eyelid abnormalities. The current issue of "Harefuah" is dedicated to contemporary knowledge in neuro-opthalmology, and spans from studies of neuromyelitis optica (NMO), ischemic optic neuropathies, and optic neuropathies induced by phosphodiesterase inhibitors, to the management of sight-threatening carotid-cavernous fistulas, and more. These studies emphasize the importance of an interdisciplinary treatment team consisting of a neuro-ophthalmologist, a neuro-radiologist, and sometimes, even a neuro-surgeon. Such an approach may prove to be beneficial to the patient, by optimizing follow-up and treatment decisions. This issue emphasizes how a correct and timely diagnosis is of paramount significance in patients with neuro-ophthalmological disorders.

  2. Analysis of ophthalmological and vision-related publications in Latin America

    Directory of Open Access Journals (Sweden)

    Lesly Carrillo Galván

    Full Text Available ABSTRACT Purpose: To assess scientific production related to ophthalmology and vision in Latin America during the period from 2006 to 2015. Methods: The PubMed, Lilacs (Bireme, Google Scholar, SciELO, and Medigraphic databases were evaluated for this retrospective, descriptive, and comparative study. Results: A total of 1,510 articles was identified. Brazil was the leader in quantitative production in ophthalmology, averaging 85.4 articles per year. Mexico was in second place with 27.4, and Argentina was in third place with 11.1 articles per year. Forty-one percent of articles were published in English, 28.1% dealt with the subspecialty of the retina, and 63% were published by researchers affiliated with universities. The frequency of male first authors was 58.9%, and the journal Arquivos Brasileiros de Oftalmologia accounted for 36.42% of the identified articles. Conclusions: Brazil stands in first place in Latin America in ophthalmologic scientific production. Nearly half of the researchers in ophthalmology in Latin America included in our study were listed in databases other than PubMed.

  3. Gender differences in successful National Institutes of Health funding in ophthalmology.

    Science.gov (United States)

    Svider, Peter F; D'Aguillo, Christine M; White, Priscilla E; Pashkova, Anna A; Bhagat, Neelakshi; Langer, Paul D; Eloy, Jean Anderson

    2014-01-01

    To determine whether gender differences in individual National Institutes of Health (NIH) awards and in funding totals exist in ophthalmology, and to further characterize whether factors such as experience, academic rank, and terminal degree play a role. A retrospective review of awards granted to primary investigators (PIs) in ophthalmology departments from 2011 through the present was conducted. PIs were classified by gender, degree, experience, and academic position. The NIH funding database was used to gather award data. Academic medical center. Men had higher mean NIH awards ($418,605) than their female colleagues ($353,170; p = 0.005) and had higher total funding per PI (p = 0.004). Men had statistically higher awards at the level of assistant professor than their female counterparts (p careers, although this difference only reached statistical significance on comparison of faculty with 10 or fewer years of experience. Male PIs receiving grants since 2011 had higher awards than their female colleagues did, most markedly among PIs in the earlier portions of their career. Differences in gender representation among senior faculty and in positions of leadership in academic ophthalmology may be partially a result of disparities in research output, as scholarly productivity is an important component of the academic advancement process in ophthalmology. Copyright © 2014 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.

  4. [Development of an ophthalmological clinical information system for inpatient eye clinics].

    Science.gov (United States)

    Kortüm, K U; Müller, M; Babenko, A; Kampik, A; Kreutzer, T C

    2015-12-01

    In times of increased digitalization in healthcare, departments of ophthalmology are faced with the challenge of introducing electronic clinical health records (EHR); however, specialized software for ophthalmology is not available with most major EHR sytems. The aim of this project was to create specific ophthalmological user interfaces for large inpatient eye care providers within a hospitalwide EHR. Additionally the integration of ophthalmic imaging systems, scheduling and surgical documentation should be achieved. The existing EHR i.s.h.med (Siemens, Germany) was modified using advanced business application programming (ABAP) language to create specific ophthalmological user interfaces for reproduction and moreover optimization of the clinical workflow. A user interface for documentation of ambulatory patients with eight tabs was designed. From June 2013 to October 2014 a total of 61,551 patient contact details were documented. For surgical documentation a separate user interface was set up. Digital clinical orders for documentation of registration and scheduling of operations user interfaces were also set up. A direct integration of ophthalmic imaging modalities could be established. An ophthalmologist-orientated EHR for outpatient and surgical documentation for inpatient clinics was created and successfully implemented. By incorporation of imaging procedures the foundation of future smart/big data analyses was created.

  5. Contingent Valuation Analysis of an Otolaryngology and Ophthalmology Emergency Department: The Value of Acute Specialty Care.

    Science.gov (United States)

    Naunheim, Matthew R; Kozin, Elliot D; Sethi, Rosh K; Ota, H G; Gray, Stacey T; Shrime, Mark G

    2017-03-01

    Specialty emergency departments (EDs) provide a unique mechanism of health care delivery, but the value that they add to the medical system is not known. Evaluation of patient preferences to determine value can have a direct impact on resource allocation and direct-to-specialist care. To assess the feasibility of contingent valuation (CV) methodology using a willingness-to-pay (WTP) survey to evaluate specialty emergency services, in the context of an ophthalmology- and otolaryngology-specific ED. Contingent valuation analysis of a standalone otolaryngology and ophthalmology ED. Participants were English-speaking adults presenting to a dedicated otolaryngology and ophthalmology ED. The WTP questions were assessed using a payment card format, with reference to an alternative modality of treatment (ie, general ED), and were analyzed with multivariate regression. Validated WTP survey administered from October 14, 2014, through October 1, 2015. Sociodemographic data, level of distress, referral data, income, and WTP. A total of 327 of 423 (77.3%) ED patients responded to the WTP survey, with 116 ophthalmology and 211 otolaryngology patients included (52.3% female; mean [range] age, 46 [18-90] years). The most common reason for seeking care at this facility was a reputation for specialty care for both ear, nose, and throat (80 [37.9%]) and ophthalmology (43 [37.1%]). Mean WTP for specialty-specific ED services was $377 for ophthalmology patients, and $321 for otolaryngology patients ($340 overall; 95% CI, $294 to $386), without significant difference between groups (absolute difference, $56; 95% CI, $-156 to $43). Self-reported level of distress was higher among ear, nose, and throat vs ophthalmology patients (absolute difference, 0.47 on a Likert scale of 1-7; 95% CI, 0.10 to 0.84). Neither level of distress, income, nor demographic characteristics influenced WTP, but patients with higher estimates of total visit cost were more likely to have higher WTP (β coefficient

  6. Angiography - interventional diagnostic applications

    International Nuclear Information System (INIS)

    Schild, H.

    1994-01-01

    The angiography system is very different from the other systems used in diagnostic radiology. The invasivity of angiography requires special, high standards in theoretical and practical training and experience both of beginners and experienced personnel. This textbook fully meets the demand for in-depth and exhaustive information, as it presents: - The fundamentals and techniques of angiography, the vascular anatomy, and many hints and tips of great help in practice. - A comprehensive survey of diagnostic problems and examination approaches, including neuro-angiography, with 221 reproductions of original angiographs, and additional schematic representations. - A special chapter devoted to indication and relevant techniques for the major vascular interventional examinations. - A great number of tables explain at a glance standard examination techniques, indications and diagnostic criteria. (orig./CB) [de

  7. Value of gallium 67 citrate scintigraphy in ophthalmology

    International Nuclear Information System (INIS)

    Ivanez-Alloschery, Monique.

    1978-01-01

    For ophthalmologists scintigraphy appears as a simple method to detect endoocular or endoorbital abnormalities. However none of the many scintigraphic methods described seems reliable enough to be used alone. One of the latest isotopic explorations using gallium 67 citrate, a tracer considered tumour-tropic might be able to solve this problem. The aim of this work is to judge the value of the method in the diagnosis of malignant endoocular and endoorbital tumours on the basis of 24 anatomoclinical observations. It may be concluded from this study that ocular gallium 67 citrate scintigraphy, which gave no clearly positive results at all but some doubtful results in the case of endoocular tumours more than 5 mm in diameter, is to be rejected; fluorescein angiography and ocular echograhy provide more elements for an accurate etiological diagnosis. Orbital scintigraphy on the other hand seems to be a necessary complement to a tomodensitometric examination since both methods offer diagnostic information without systematic recurse to carotid arteriography or orbital phlebography, sometimes dangerous for the patient [fr

  8. Diagnostic planning in JT-60 project

    International Nuclear Information System (INIS)

    Matoba, Tohru; Suzuki, Yasuo; Funahashi, Akimasa; Itagaki, Tokiyoshi

    1977-08-01

    The diagnostic plans of JT-60 were made along with design of the main machine. Basic requirements of the diagnostic program are (1) multiple measurement of respective plasma parameters, (2) efficient usage of the discharge, (3) capable data acquisition system, (4) high reliability of the diagnostic equipments, and (5) systematic development of new diagnostic techniques. Dimensions of the diagnostic ports were determined in detailed design of the vacuum vessel, anticipating the possible diagnostic methods. The proposed diagnostic systems and the plans are shown in table and figures respectively. Problems in the diagnostics are also described. (auth.)

  9. Intercomparison of techniques for inspection and diagnostics of heavy water reactor pressure tubes: Flaw detection and characterization [Phase 1] [Sample summary reports of pressure tube samples from Argentina, India, Canada, Republic of Korea, and Romania

    International Nuclear Information System (INIS)

    2006-05-01

    Nuclear power plants with heavy water reactors (HWRs) comprise nine percent of today's operating nuclear units, and more are under construction. Efficient and accurate inspection and diagnostic techniques for various reactor components and systems are an important factor in assuring reliable and safe plant operation. To foster international collaboration in the efficient and safe use of nuclear power, the IAEA conducted a Coordinated Research Programme (CRP) on Inter-comparison of Techniques for HWR Pressure Tube Inspection and Diagnostics. This CRP was carried out within the frame of the IAEA Department of Nuclear Energy's Technical Working Group on Advanced Technologies for HWRs (the TWG-HWR). The TWG-HWR is a group of experts nominated by their governments and designated by the IAEA to provide advice and to support implementation of the IAEA's project on advanced technologies for HWRs. The objective of the CRP was to inter-compare non-destructive inspection and diagnostic techniques, in use and being developed, for structural integrity assessment of HWR pressure tubes. During the first phase of this CRP, participants have investigated the capability of different techniques to detect and characterize flaws. During the second phase of this CRP, participants collaborated to detect and characterize hydride blisters and to determine the hydrogen concentration in Zirconium alloys. The intent was to identify the most effective pressure tube inspection and diagnostic methods, and to identify further development needs. The organizations that have participated in this CRP are: - The Comision Nacional de Energia Atomica (CNEA), Argentina; - Atomic Energy of Canada Ltd. (AECL); Chalk River Laboratories (CRL), Canada; - The Research Institute of Nuclear Power Operations (RINPO), China National Nuclear Corporation (CNNC), China; - Bhabha Atomic Research Centre (BARC), India; - The Korea Electric Power Research Institute (KEPRI), Republic of Korea; - The Korea Atomic Energy

  10. A Partnership Training Program in Breast Cancer Diagnosis: Concept Development of the Next Generation Diagnostic Breast Imaging Using Digital Image Library and Networking Techniques

    National Research Council Canada - National Science Library

    Chouikha, Mohamed F

    2004-01-01

    ...); and Georgetown University (Image Science and Information Systems, ISIS). In this partnership training program, we will train faculty and students in breast cancer imaging, digital image database library techniques and network communication strategy...

  11. Influence of diagnostic quality scanning technique with CR mammography; Influencia de la tecnica de exploracion en la calidad diagnostica de la mamografia ocn CR

    Energy Technology Data Exchange (ETDEWEB)

    Rivas Ballarin, M. A.; Ruiz Manzano, P.; Ortega Pardina, P.; Laliena Bielsa, V.; Calvo Carrillo, S.; Garcia Romero, A.; Millan Cebrian, E.

    2013-07-01

    Image quality criteria laid down in the Spanish Protocol of Control of quality in Radiology (PECCR) to a team of mammography with CR imaging system are applied in this work and evaluated the dosimetry impact implied by the modification of the technique of exposure required for the fulfilment of those criteria. Is also analyzes the impact on the image quality of the new radiographic technique, evaluated by three radiologists. (Author)

  12. Molecular Diagnostics

    OpenAIRE

    Choe, Hyonmin; Deirmengian, Carl A.; Hickok, Noreen J.; Morrison, Tiffany N.; Tuan, Rocky S.

    2015-01-01

    Orthopaedic infections are complex conditions that require immediate diagnosis and accurate identification of the causative organisms to facilitate appropriate management. Conventional methodologies for diagnosis of these infections sometimes lack accuracy or sufficient rapidity. Current molecular diagnostics are an emerging area of bench-to-bedside research in orthopaedic infections. Examples of promising molecular diagnostics include measurement of a specific biomarker in the synovial fluid...

  13. β-trace protein as a diagnostic marker for perilymphatic fluid fistula: a prospective controlled pilot study to test a sample collection technique.

    Science.gov (United States)

    Bachmann-Harildstad, Gregor; Stenklev, Niels Christian; Myrvoll, Elin; Jablonski, Greg; Klingenberg, Olav

    2011-01-01

    The diagnosis of perilymphatic fluid (PLF) fistula is still challenging. Perilymphatic fluid fistula is one possible complication after stapedotomy or cochlear implant surgery. We have performed a prospective diagnostic pilot study to further investigate β-trace protein (β-TP) as a marker for PLF fistula. In this pilot study, we tested the sensitivity of the β-TP marker using a simple method for sample collection from the tympanic cavity. Prospective controlled diagnostic study. Two-center tertiary referral hospitals. A total of 35 adult patients undergoing ear surgery were included. Subjects were divided into 2 groups: 1) 19 patients undergoing stapedotomy were investigated for PLF fistula in samples obtained from the tympanic cavity and 2) 16 patients undergoing myringoplasty were investigated for PLF fistula in samples from the tympanic cavity. This group served as the control. Mean age +/- SD at surgery was 49.9 +/- 8.0 years in the study group and 39.69 +/- 15.47 years in the control group. β-Trace protein (prostaglandin D synthase) in tympanic cavity samples and serum samples was analyzed. The samples were collected by gradually filling the tympanic cavity with 100 to 200 μl sodium chloride and by immediately collecting a volume of 60 to 100 μl in a mucus specimen set container. The concentration of β-TP was quantified using laser nephelometry. The median β-TP in the study group was 0.8 mg/L (range, 0.05-4.5 mg/L). In the control group, the median β-TP value was 0.16 mg/L (range, 0.01-0.36 mg/L). Thirty-five percent of the values in the study group were below the highest value in the negative control group. The β-TP values of the tympanic cavity samples were significantly higher in the study group than in controls (p = 0.0001). The serum values were 0.55 +/- 0.18 and 0.53 +/- 0.11 mg/L, respectively. It may be feasible to test for PLF fistula using β-TP in samples from the tympanic cavity. Our results, however, suggest a relative low diagnostic

  14. Diagnostic imaging of craniopharyngioma

    International Nuclear Information System (INIS)

    Gradzki, J.; Nowak, S.; Paprzycki, W.

    1993-01-01

    40 patients have been examined with operational and histological confirmation of craniopharyngioma. CT image and X-ray plane of skull were performed in case all of these patients. TMR was conformed to examine 4 patients. X-ray planes was compared to CT. CT permits tumor cyst detection. The efficacy of mentioned above diagnostic techniques was compared with surgical findings. (author)

  15. Diagnostic studies in amyloidosis

    NARCIS (Netherlands)

    Hazenberg, Bouke Pier Cornelis

    2007-01-01

    In this thesis two diagnostic techniques are studied in amyloidosis. Systemic amyloidosis is characterized by deposition of amyloid fibrils (tiny fibres) throughout the body resulting in damage of vital organs. Amyloid can be detected in a tissue specimen stained with Congo red: red-stained amyloid

  16. [Understanding the advantages and disadvantages of femtosecond laser comprehensive applications in ophthalmology].

    Science.gov (United States)

    Xie, Li-xin; Gao, Hua

    2013-04-01

    The femtosecond (FS) laser is a novel laser technology, and is approved clinical application by FDA in 2000. FS laser initially mainly used in corneal refractive surgery to replace the mechanical microkeratome. Since the accuracy and controllability of the FS laser is very high, it shows superiority in the field of corneal refractive surgery. And with the development of the relative hard and software, FS laser is began to used in other fields of ophthalmology, such as corneal transplants, cataract surgery, as well as assisted diagnosis et al., although still have some limitations, the preliminary clinical results have been shown a very good prospects in the ophthalmology fields. Therefore, we reviewed the alternative applications, challenges and limitations, research direction in the future of FS laser, so that provide a reference and revelations for the peers.

  17. Basic and clinical application progression of invigorating blood and dissolving stasis Chinese medicine in ophthalmology

    Directory of Open Access Journals (Sweden)

    Ying Wang

    2017-06-01

    Full Text Available Invigorating blood and dissolving stasis method is a kind of unique therapy of Traditional Chinese Medicine(TCMtreatment, which efficacy has become increasingly prominent in the treatment of ophthalmology. With the further studies of blood stasis and invigorating blood and dissolving stasis therapy, it is widely used in clinical ophthalmology, and get good effects beyond thought, especially when western medicine has no curative effects. It improved the cure rate of fundus oculi disease from the eyelids, conjunctiva, lacrimal sac, vitreous body to the choroid and retina, optic nerve and macula lutea, from surface to fundus, or pathological changes related to inflammation, degeneration, necrosis, atrophy, hyperplasia of fibrous tissue hyperplasia. This paper is aim to explain the definition of invigorating blood and dissolving stasis and make a review of basic research and clinical application about it in several diseases.

  18. Usefulness of post-mortem ophthalmological endoscopy during forensic autopsy: a case report.

    Science.gov (United States)

    Tsujinaka, Masatake; Akaza, Kayoko; Nagai, Atsushi; Nakamura, Isao; Bunai, Yasuo

    2005-01-01

    Post-mortem intraocular findings in two autopsy cases with traumatic intracranial haemorrhage were obtained using an ophthalmological endoscope. The endoscopy results clearly revealed the presence of intraocular haemorrhages and papilledema caused by intracranial haemorrhage. Post-mortem ophthalmological endoscopy offers several benefits. First, post-mortem intraocular findings can be directly observed in corpses with post-mortem clouding of the cornea. Secondly, the endoscopy only requires a 0.9 mm incision in the sclera and does not require the removal of the eye from the corpse, a procedure that should be avoided for ethical and cosmetic reasons. Thus, post-mortem opthalmological endoscopy is a useful method for obtaining intraocular findings in autopsies.

  19. A Randomized Controlled Study of Art Observation Training to Improve Medical Student Ophthalmology Skills.

    Science.gov (United States)

    Gurwin, Jaclyn; Revere, Karen E; Niepold, Suzannah; Bassett, Barbara; Mitchell, Rebecca; Davidson, Stephanie; DeLisser, Horace; Binenbaum, Gil

    2018-01-01

    Observation and description are critical to the practice of medicine, and to ophthalmology in particular. However, medical education does not provide explicit training in these areas, and medical students are often criticized for deficiencies in these skills. We sought to evaluate the effects of formal observation training in the visual arts on the general and ophthalmologic observational skills of medical students. Randomized, single-masked, controlled trial. Thirty-six first-year medical students, randomized 1:1 into art-training and control groups. Students in the art-training group were taught by professional art educators at the Philadelphia Museum of Art, during 6 custom-designed, 1.5-hour art observation sessions over a 3-month period. All subjects completed pre- and posttesting, in which they described works of art, retinal pathology images, and external photographs of eye diseases. Grading of written descriptions for observational and descriptive abilities by reviewers using an a priori rubric and masked to group assignment and pretesting/posttesting status. Observational skills, as measured by description testing, improved significantly in the training group (mean change +19.1 points) compared with the control group (mean change -13.5 points), P = 0.001. There were significant improvements in the training vs. control group for each of the test subscores. In a poststudy questionnaire, students reported applying the skills they learned in the museum in clinically meaningful ways at medical school. Art observation training for first-year medical students can improve clinical ophthalmology observational skills. Principles from the field of visual arts, which is reputed to excel in teaching observation and descriptive abilities, can be successfully applied to medical training. Further studies can examine the impact of such training on clinical care. Copyright © 2017 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  20. Representation of ophthalmology concepts by electronic systems: adequacy of controlled medical terminologies.

    Science.gov (United States)

    Chiang, Michael F; Casper, Daniel S; Cimino, James J; Starren, Justin

    2005-02-01

    To assess the adequacy of 5 controlled medical terminologies (International Classification of Diseases 9, Clinical Modification [ICD9-CM]; Current Procedural Terminology 4 [CPT-4]; Systematized Nomenclature of Medicine, Clinical Terms [SNOMED-CT]; Logical Identifiers, Names, and Codes [LOINC]; Medical Entities Dictionary [MED]) for representing concepts in ophthalmology. Noncomparative case series. Twenty complete ophthalmology case presentations were sequentially selected from a publicly available ophthalmology journal. Each of the 20 cases was parsed into discrete concepts, and each concept was classified along 2 axes: (1) diagnosis, finding, or procedure and (2) ophthalmic or medical concept. Electronic or paper browsers were used to assign a code for every concept in each of the 5 terminologies. Adequacy of assignment for each concept was scored on a 3-point scale. Findings from all 20 case presentations were combined and compared based on a coverage score, which was the average score for all concepts in that terminology. Adequacy of assignment for concepts in each terminology, based on a 3-point Likert scale (0, no match; 1, partial match; 2, complete match). Cases were parsed into 1603 concepts. SNOMED-CT had the highest mean overall coverage score (1.625+/-0.667), followed by MED (0.974+/-0.764), LOINC (0.781+/-0.929), ICD9-CM (0.280+/-0.619), and CPT-4 (0.082+/-0.337). SNOMED-CT also had higher coverage scores than any of the other terminologies for concepts in the diagnosis, finding, and procedure categories. Average coverage scores for ophthalmic concepts were lower than those for medical concepts. Controlled terminologies are required for electronic representation of ophthalmology data. SNOMED-CT had significantly higher content coverage than any other terminology in this study.

  1. Neuro-Ophthalmology at a Tertiary Eye Care Centre in India.

    Science.gov (United States)

    Dhiman, Rebika; Singh, Digvijay; Gantayala, Shiva P; Ganesan, Vaitheeswaran L; Sharma, Pradeep; Saxena, Rohit

    2017-11-09

    Neuro-ophthalmology as a specialty is underdeveloped in India. The aim of our study was to determine the spectrum and profile of patients presenting to a tertiary eye care center with neuro-ophthalmic disorders. A retrospective hospital-based study was conducted, and records of all patients seen at the neuro-ophthalmology clinic of Dr. Rajendra Prasad Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, New Delhi, India, over a 1-year period were retrieved and evaluated. Of a total of 30,111 patients referred to various specialty clinics in a span of 1 year, 1597 (5%) were referred for neuro-ophthalmology evaluation. The mean patient age was 30.8 ± 19.5 years, with a male dominance (M:F = 2.02:1). Among these patients, optic nerve disorders were noted in 63.8% (n = 1,020), cranial nerve palsy in 7% (n = 114), cortical visual impairment in 6.5% (n = 105), and others (eye/optic nerve hypophasia, blepharospasm, and optic disc drusen) in 6% (n = 95). Among the patients with optic nerve disorders, optic neuropathy without disc edema/(traumatic optic neuropathy, hereditary, tumor-related, retrobulbar neuritis, toxic, and idiopathic) was noted in 42.8% (n = 685) and optic neuropathy with disc edema (ischemic optic neuropathy, papilledema, post-papilledema optic atrophy, papillitis, neuroretinitis, and inflammatory optic neuropathy) in 20.9% (n = 335). Sixteen percent of patients (n = 263) were incorrect referrals. The neuro-ophthalmic clinic constitutes a significant referral unit in a tertiary eye care center in India. Traumatic and ischemic optic neuropathies are the most common diagnoses. Neuro-ophthalmology requires further development as a subspecialty in India to better serve the nation's population.

  2. Ophthalmology patients' interest in online access to clinic notes at three US clinics.

    Science.gov (United States)

    Lee, Bryan S; Oster, Natalia V; Chen, Galen Y; Ding, Leona L; Walker, Janice D; Elmore, Joann G

    2017-07-01

    This study aimed to understand patients' perceptions about potential benefits and harms of accessing their own ophthalmology clinic notes via an electronic patient portal as part of the OpenNotes initiative. The authors conducted a cross-sectional, in-person survey of ophthalmology patients at three US eye clinics. The paper survey was self-administered or administered with assistance from study staff before or after patients' clinical visits. The authors used descriptive statistics to summarise patient characteristics and patient attitudes about accessing their ophthalmology notes online. Chi-square and t-tests were performed to assess differences in patient responses between clinic locations. Four hundred and fifty-one patients responded (response rate 65%). Most patients thought that accessing doctors' notes online was a good idea (95%), wanted to view their clinic notes online (94%), and agreed online access would increase their understanding of their eye problems (95%) and help them better remember their care plan (94%); 14% said online access would increase their worry; 43% had privacy concerns; and 96% indicated they would show or discuss their notes with at least one other person. Non-white patients were more likely than white patients to perceive online clinic notes as a useful tool, but they were also more likely to worry and to express greater privacy concerns. Patients at three US eye clinics were strongly in favour of online access to ophthalmology notes and were optimistic this access would improve their understanding and self-care. Ophthalmologists should consider offering online access to their notes to enhance doctor-patient communication and improve clinical outcomes. © 2017 The Authors Ophthalmic & Physiological Optics © 2017 The College of Optometrists.

  3. A forecast of ophthalmology practice trends in saudi arabia: a survey of junior residents.

    Science.gov (United States)

    Alwadani, Fahad; Alrushood, Aziz; Altokhy, Hisham; Alasbali, Tariq

    2010-10-01

    The aim of this study is to identify the trends in practice pattern among current ophthalmology residents in Saudi Arabia. Ophthalmology residents in Saudi Arabia responded anonymously to a written survey between November 2007 and February 2008. The survey contained questions on demographic information, medical education, residency training, career goals and factors influencing their career choice. The data were categorized by gender. The influence of gender on outcome was assessed in a univariate fashion using the Chi-square or Fisher exact test when appropriate. A P-value of 0.05 or less was considered statistically significant for all analyses. A total of 68 out of 85 residents (80%) responded to the survey. Over one-half of the residents preferred to pursue a fellowship within Saudi Arabia (53%), while others (25%) planned to train in North America. The majority of respondents wished to practice in an urban setting (63%). Anterior segment was the most desired subspecialty, while general ophthalmology and glaucoma were not a popular choice. Most residents were interested in refractive surgery (77%) and research (75%). The main factor influencing the decision to pursue ophthalmology was the ability to combine medicine and surgery (97%), while a positive elective experience was also an important factor, particularly for female respondents (91% vs. 57%; P < 0.001). Concerted efforts are required to encourage adoption to ophthalmic practice in public institutions rather than in private practice. In addition training in underrepresented subspecilaties should be encouraged to ensure adequate ophthalmic care for all citizens of Saudi Arabia.

  4. Measuring the differences in work ratios between pediatric and adult ophthalmologic examinations.

    Science.gov (United States)

    Hyun, Joo; Chang, Jee Ho; Kim, Seung Hoon; Park, Song Hee; Kim, Sunghoon

    2017-06-01

    To assess the differences in work needed for pediatric and adult ophthalmologic examinations. Seven ophthalmology residents conducted slit-lamp and refraction examinations on children 3-7 years of age and adults 20-69 years of age. The examiners reported the magnitude estimate (ME) of their work in relation to two references (cross-reference ME): average adult examination and average pediatric examination. The examination time was also measured. For the slit-lamp examination, 50 children and 58 adults were recruited. The ME was 1.45 (95% CI, 1.30-1.62) times higher for the pediatric examinations than for the adult examinations when the reference was an average adult case. With respect to time, the pediatric examinations took 1.22 (95% CI, 1.06-1.41) times longer than the adult examinations. For the refraction examinations, 58 children and 96 adults were recruited. The ME was 1.35 (95% CI, 1.21-1.52) times higher for the pediatric examinations. The pediatric examination took 1.32 (95% CI, 1.16-1.50) times longer than the adult examination. The cross-reference ME ratios measuring the pediatric over adult examinations against both the pediatric and adult reference cases were equivalent in both the slit-lamp and the refraction examinations; however, the ME and time ratios of the pediatric over the adult examinations were not equivalent for the slit-lamp or for the refraction examinations. The cross-reference ME showed that pediatric ophthalmologic examinations require more work than the adult examination with validity and reliability. The time estimate was insufficient as a single indicator for work estimation. Copyright © 2017 American Association for Pediatric Ophthalmology and Strabismus. Published by Elsevier Inc. All rights reserved.

  5. Ophthalmologic abnormalities in Mowat-Wilson syndrome and a mutation in ZEB2.

    Science.gov (United States)

    Ariss, Michelle; Natan, Kristina; Friedman, Neil; Traboulsi, Elias I

    2012-09-01

    Mowat-Wilson syndrome is a genetic disorder characterized by a distinct facial appearance, moderate-to-severe mental retardation, microcephaly, agenesis of the corpus callosum, Hirschsprung disease, congenital heart disease, and genital anomalies. Ophthalmological abnormalities have been rarely described in patients with this condition which is caused by mutations in the ZEB2 gene. We report a 9-year-old female with this syndrome who has severe ocular abnormalities including bilateral microphthalmia, cataract, and retinal aplasia.

  6. Teaching Neuro-Ophthalmology in the Asia-Pacific Region and China: A Personal Perspective.

    Science.gov (United States)

    Crompton, John

    2015-12-01

    Over the last 30 years, I have been involved in a number of projects helping to educate and train local ophthalmologists in many parts of Asia and the Pacific Islands, which lack adequate training and service in neuro-ophthalmology. In this article, I offer an overview of a number of different teaching initiatives and offer practical suggestions to anyone who might wish to become involved.

  7. [Deep learning and neuronal networks in ophthalmology : Applications in the field of optical coherence tomography].

    Science.gov (United States)

    Treder, M; Eter, N

    2018-04-19

    Deep learning is increasingly becoming the focus of various imaging methods in medicine. Due to the large number of different imaging modalities, ophthalmology is particularly suitable for this field of application. This article gives a general overview on the topic of deep learning and its current applications in the field of optical coherence tomography. For the benefit of the reader it focuses on the clinical rather than the technical aspects.

  8. Exploration and deliberation of on-job postgraduates training in clinical ophthalmology

    Directory of Open Access Journals (Sweden)

    Wei-Jia Dai

    2014-07-01

    Full Text Available With the diversified development in training clinical students, an impeccable system in clinical on-job postgraduates training has been established. It has been being an important problem for colleges and tutors to improve the quality in the postgraduates training program in the specialty of ophthalmology. This paper analyzed the problems in the training of clinical postgraduates and explored the ways to resolve the problems.

  9. On textual and contextual position of the ophthalmological treatise of bodhisattva nāgārjuna.

    Science.gov (United States)

    Kim, Seongsu; Kang, Sungyong

    2013-04-01

    Medical knowledge in India began to be introduced to China in earliest from the Later Han Dynasty period to the times of Wei-Qin and South & North Dynasties. This is proved by many Buddhist medical books appeared in those days. Of the contents of Indian medicine, the theory of four major elements affected Chinese medicine more than did the theory of body fluids. Based on the theory of four major elements that was began to be introduced in Fú shuō fú yī jīng, an attempt to establish a new medical system was made in Zhŏu hòu băi yīfāng written by Táo Hóng-jĭng and Sūn Sī-miăo who tried to develop etiology further but could not achieve any great outcomes. Unlike the foregoing situation, Indian medicine aroused a large echo in China in the field of ophthalmology with ophthalmological knowledge mentioned in Suśrutasa hitā and 'Jīnzhēn-shù'(cataract couching) introduced as a surgical treatment of cataract. The Suśrutasa hitā which is one of the three major texts of Indian medicine contains additional information on surgical operations not introduced in the Carakasa hitā. The technique of cataract surgery was particularly popular in the Tang and Song dynasty periods in China under the name Lóng shù pú sà yăn lùn(The Ophthalmological Treatise of Bodhisattva Nāgārjuna) or Lóng shù lùn and was even designated as a subject to educate medical officers. While the original text of Lóng shù pú sà yăn lùn was not handed down, the first testimony that show the trace of the introduction of this text into China was the Tiān zhú jīng lùn yăn mentioned in Wài tái mì yào(Arcane Essential from the Imperial Library) written by Wang Tao. Long shàng dào ren who was mentioned as the compiler of the book is assumed to be Lóng shù. Although Tiān zhú jīng lùn yăn introduced anatomical knowledge about the eyeball that could have not been in the traditional Chinese medicine, this book has only limited quantity of information in this

  10. Effects of hand massage on anxiety in patients undergoing ophthalmology surgery using local anesthesia

    Directory of Open Access Journals (Sweden)

    Jafar Rafiei Kiasari

    2012-08-01

    Full Text Available Introduction: Anxiety is a common disorder in patients before surgery. Inappropriately managed anxiety can cause psychological and physiological reactions and will affect the process of surgery and recovery. Therefore, this study examined the effects of hand mas-sage on anxiety in patients undergoing ophthalmology surgery using local anesthesia. Methods: In this interventional study, 52 patients who were supposed to undergo oph-thalmology surgery using local anesthesia were studied. Patients were randomly as-signed to two groups of intervention, who received hand massage before surgery (n = 27 and control (n = 25. Massaging lasted for 5 minutes (2.5 minutes on each hand before surgery. Stroking and scrubbing methods were performed by 2 trained research-ers. Anxiety level, blood pressure, heart rate, and respiratory rate were measured before and after the intervention in both groups. Anxiety was evaluated using Spielberger State-Trait Anxiety Inventory. Data was analyzed by chi-square, independent samples t-test, and paired t-test. Results: There were no significant differences in mean anxiety, systolic blood pressure, diastolic blood pressure, heart rate, and respiratory rate between the two groups before the intervention (p > 0.05. However, there was a significant differenc in the mean stress level between the two groups after the intervention (p 0.05. Conclusion: Our findings suggested that 5 minutes of hand massage before ophthalmology surgery (under local anesthesia could reduce anxiety. Therefore, this method can be used to increase patient comfort and reduce anxiety before surgical interventions.

  11. Ophthalmology's future in the next decade: a historical and comparative perspective.

    Science.gov (United States)

    Day, S H

    1999-01-01

    To gain a historical and comparative perspective about the future of ophthalmology within the profession of medicine. A literature search is made of disciplines other than medicine (history, sociology, philosophy, economics, and ethics) in order to assess factors responsible for survival and healthiness of a profession. The "learned" professions (medicine, law, and theology) are assessed. Other "professional" careers valued by society (sports and classical music) are reviewed. From the perspective of other disciplines, the future of ophthalmology is seen as vulnerable and fragile. Survival of professions, be they classically or economically defined, is linked to societal needs, a profession's unique commitment and ability to provide services to society, and the profession's maintenance of knowledge as well as skill-based services. Historical evidence has shown erosion of a profession's power consequent to capitalist influences, government influences, access of skills by less trained individuals, and elitist posturing by a profession. Comparative evidence has shown societal acceptance of an escalation of salaries for designated superstars, increasing roles and influence of managerial personnel, and trivialization of values other than economic ones. Attention to historical and comparative trends by individual ophthalmologists as well as associations representing ophthalmologists is mandatory if ophthalmology as we know it is to survive within the profession of medicine.

  12. International Council of Ophthalmology: Refocusing Ophthalmic Education in the Asia-Pacific Region and Beyond.

    Science.gov (United States)

    Golnik, Karl; Mayorga, Eduardo; Spivey, Bruce; Ritch, Robert; Gauthier, Tina-Marie

    2012-01-01

    The International Council of Ophthalmology (ICO) is a global organization with a regional focus. Working in partnership with supranational and ICO member societies, the ICO is building a "World Alliance for Sight" to improve access to the highest-quality eye care worldwide. Designed to preserve and restore vision on an international scale, the ICO initiative, "Refocusing Ophthalmic Education," enhances ophthalmic education of residents, subspecialists, medical students, and allied eye care personnel by redefining the most effective ways to teach and in creating beneficial educational opportunities. The "Teaching the Teachers" program helps ophthalmic educators incorporate more effective methods of training and continuing professional development to meet societal needs, achieved in part through regional courses for residency program directors; symposia, and keynote talks presented by ICO's World Ophthalmology Educational Colloquium, Conferences for Ophthalmic Educators, and ophthalmic surgical competency rubrics. Recognizing that standardized curricula are essential for consistent ophthalmic education, the ICO has developed a curricular framework whereby goals, expectations, knowledge base, competencies, and technical training are delineated. The ICO is defining worldwide models of team training and compiling best practice, which will include training-program accreditation to ensure improvement in the education of ophthalmologists. International Council of Ophthalmology Web-based teaching courses, a Webinar Network, and a technology blog further support information and communication technologies for teaching and learning. At the ICO's Center for Ophthalmic Educators (educators.icoph.org), trainers will find valuable teaching resources in multiple languages as well as ways to share ideas and collaborate with peers and other ophthalmic educators.

  13. [CME-certified online education in Germany - status in ophthalmology 2011].

    Science.gov (United States)

    Handzel, D M

    2012-06-01

    The use of the internet is becoming more and more important in every aspect of daily life, also in professional education. Online education and face-to-face learning have proven to be equally efficient. The aim of this study is to evaluate the amount of online education in the German-speaking internet 2011. The terms "ophthalmology", "online-education", "continuing medical education" and "CME" (partly in German language) were searched by an internet-search engine. The first 100 pages were visited. Pages were evaluated in respect of quality and quantity, authorship and possible influence of sponsors. Only 9 of the first 100 hits had an actual offer for ophthalmology. Nearly all of these were websites of ophthalmological scientific journals. The content represented the same educational format (pictures and text) as in the print issue. CME-certified online education can be found in Germany as offspring of print issues only. The content is identical with educational texts in the print issues. An enlargement of the offer, which uses the possibilities of modern internet technology is highly probable. This estimation is supported by the growing use of the internet and developments on English-speaking websites for online-education. © Georg Thieme Verlag KG Stuttgart · New York.

  14. [Clinical and therapeutic differences in neuro-ophthalmological involvement secondary to syphilis].

    Science.gov (United States)

    Crespo-Burillo, J A; Gil-Perez, D; Alarcia-Alejos, R; Hernando-Quintana, N; Garcia-Rubio, S; Martin-Martinez, J

    2014-09-16

    INTRODUCTION. There are many forms of neuro-ophthalmological involvement secondary to syphilis, and not all of them are well known. Our aim is to determine the clinical and therapeutic differences in these patients. CASE REPORTS. Our sample included eight patients diagnosed with an ocular and neuro-ophthalmological disorder due to syphilis over the years 2012 and 2013. Five of them presented uveitis, pan-eveitis being the most frequent, with three cases. Two cases presented papilloedema and another displayed retrobulbar optic neuropathy. A total of 62.5% were diagnosed with neurosyphilis, the presence of which was related with compromise of the optic nerve (p = 0.035). None of them gave positive for VDRL in cerebrospinal fluid and they were diagnosed by the presence of FTA antibodies together with high protein levels in cerebrospinal fluid, lymphocytic pleocytosis or intrathecal synthesis of antibodies. In the absence of uveitis, diagnosis was delayed by a mean time of 2.6 months (p = 0.047). All the patients, except one who required a vitrectomy, progressed favourably with intravenous antibiotic therapy. CONCLUSIONS. In cases of neuro-ophthalmological compromise, whether inflammatory or non-inflammatory, the physician must bear syphilis in mind as a potential causation in order to avoid delays in the diagnosis, since early well-tailored treatment can prevent permanent loss of sight.

  15. P3-1: Ophthalmologic Factors Influencing Asthenopia with Watching 3D Displays

    Directory of Open Access Journals (Sweden)

    Sungwook Wee

    2012-10-01

    Full Text Available Purpose: To identify ophthalmologic factors influencing asthenopia while watching 3D displays. Methods: 30 adult subjects without ophthalmologic abnormality watched the same 3D displays for 30 minutes. Each subject's far and near visual acuity, near points of accommodation and convergence, amplitude of fusional convergence and divergence, stereopsis, angle of phoric deviation, tear break-up time, and temperature of ocular surface before and after watching 3D displays were measured. And surveys for subjective symptoms right after watching 3D displays were conducted. The above-mentioned experiments were performed equally with 2D displays for detection of innate influence of 3D displays. Results: The near points of accommodation and convergence were significantly changed after watching 3D displays (p < .05 compared to 2D displays. And all 10 subjective symptoms were significantly increased after watching 3D displays (p < .05. Conclusion: The accommodation and binocular vergence are predominant ophthalmologic factors that might influence asthenopia significantly while watching 3D displays. Subjective visual discomfort significantly increases with watching 3D displays, and more specific evaluation should be added for detecting the practically related factors with asthenopia.

  16. Ophthalmological screening of a paediatric cochlear implant population: a retrospective analysis and 12-year follow-up.

    LENUS (Irish Health Repository)

    Falzon, K

    2010-06-01

    To determine the nature and prevalence of ophthalmological findings for a cohort of children in a paediatric cochlear implant program and to assist the clinician in devising an investigative plan for this population.

  17. Diagnostics of anterior eye segment in cats and dogs

    Directory of Open Access Journals (Sweden)

    Hadži-Milić Milan

    2006-01-01

    Full Text Available Diagnostics of the anterior segment of the eye present the most frequent diagnostics implemented in ophthalmology and by most veterinary practicians as well. This paper presents the complete diagnostics in the most concise form possible. The procedure with animals is presented first, followed by the equipment, and then anamnesis. The following diagnostic methods are presented: examination in a lighted room which include an examination from a distance, taking a smear, the Schirmer tear test (STT, an examination from close by, examination in a dark room which comprises the elementary examinations, such as the use of focal lighting and examination using a direct ophthalmoscope, and special examination in a dark room, such as biomicroscopy, gonioscopy and keratoscopy. Additional examination methods are also included.

  18. Companion diagnostics

    DEFF Research Database (Denmark)

    Jørgensen, Jan Trøst; Hersom, Maria

    2016-01-01

    of disease mechanisms, things are slowly changing. Within the last few years, we have seen an increasing number of predictive biomarker assays being developed to guide the use of targeted cancer drugs. This type of assay is called companion diagnostics and is developed in parallel to the drug using the drug-diagnostic...... co-development model. The development of companion diagnostics is a relatively new discipline and in this review, different aspects will be discussed including clinical and regulatory issues. Furthermore, examples of drugs, such as the ALK and PD-1/PD-L1 inhibitors, that have been approved recently....... Despite having discussed personalized medicine for more than a decade, we still see that most drug prescriptions for severe chronic diseases are largely based on 'trial and error' and not on solid biomarker data. However, with the advance of molecular diagnostics and a subsequent increased understanding...

  19. Pitfalls in diagnostic radiology

    Energy Technology Data Exchange (ETDEWEB)

    Peh, Wilfred C.G. (ed.) [Khoo Teck Puat Hospital (Singapore). Dept. of Diagnostic Radiology

    2015-04-01

    Only textbook to focus primarily on the topic of pitfalls in diagnostic radiology. Highlights the pitfalls in a comprehensive and systematic manner. Written by experts in different imaging modalities and subspecialties from reputable centers across the world. The practice of diagnostic radiology has become increasingly complex, with the use of numerous imaging modalities and division into many subspecialty areas. It is becoming ever more difficult for subspecialist radiologists, general radiologists, and residents to keep up with the advances that are occurring year on year, and this is particularly true for less familiar topics. Failure to appreciate imaging pitfalls often leads to diagnostic error and misinterpretation, and potential medicolegal problems. Diagnostic errors may be due to various factors such as inadequate imaging technique, imaging artifacts, failure to recognize normal structures or variants, lack of correlation with clinical and other imaging findings, and poor training or inexperience. Many, if not most, of these factors are potentially recognizable, preventable, or correctable. This textbook, written by experts from reputable centers across the world, systematically and comprehensively highlights the pitfalls that may occur in diagnostic radiology. Both pitfalls specific to different modalities and techniques and those specific to particular organ systems are described with the help of numerous high-quality illustrations. Recognition of these pitfalls is crucial in helping the practicing radiologist to achieve a more accurate diagnosis.

  20. Pitfalls in diagnostic radiology

    International Nuclear Information System (INIS)

    Peh, Wilfred C.G.

    2015-01-01

    Only textbook to focus primarily on the topic of pitfalls in diagnostic radiology. Highlights the pitfalls in a comprehensive and systematic manner. Written by experts in different imaging modalities and subspecialties from reputable centers across the world. The practice of diagnostic radiology has become increasingly complex, with the use of numerous imaging modalities and division into many subspecialty areas. It is becoming ever more difficult for subspecialist radiologists, general radiologists, and residents to keep up with the advances that are occurring year on year, and this is particularly true for less familiar topics. Failure to appreciate imaging pitfalls often leads to diagnostic error and misinterpretation, and potential medicolegal problems. Diagnostic errors may be due to various factors such as inadequate imaging technique, imaging artifacts, failure to recognize normal structures or variants, lack of correlation with clinical and other imaging findings, and poor training or inexperience. Many, if not most, of these factors are potentially recognizable, preventable, or correctable. This textbook, written by experts from reputable centers across the world, systematically and comprehensively highlights the pitfalls that may occur in diagnostic radiology. Both pitfalls specific to different modalities and techniques and those specific to particular organ systems are described with the help of numerous high-quality illustrations. Recognition of these pitfalls is crucial in helping the practicing radiologist to achieve a more accurate diagnosis.

  1. Diagnostics of Gun Barrel Propellants

    National Research Council Canada - National Science Library

    Lederman, S

    1983-01-01

    A preliminary investigation of the applicability of the spontaneous Raman diagnostic technique to the determination of the temperature of the propellant gases in the vicinity of the muzzle of a 2Omm...

  2. Environmental sensing and combustion diagnostics

    International Nuclear Information System (INIS)

    Santoleri, J.J.

    1991-01-01

    This book contains proceedings of Environmental Sensing and Combustion Diagnostics. Topics covered include: Incineration Systems Applications, Permitting, And Monitoring Overview; Infrared Techniques Applied to Incineration Systems; Continuous Emission Monitors; Analyzers and Sensors for Process Control And Environmental Monitoring

  3. Laser Diagnostics for Reacting Flows

    National Research Council Canada - National Science Library

    Hanson, Ronald K

    2007-01-01

    ... (UV) or infrared (IR) wavelengths. The cw lasers were spectrally narrow, allowing study of innovative diagnostics based on spectral lineshapes, while the pulsed lasers provided intense bursts of photons needed for techniques based on LIF...

  4. Mental stress as consequence and cause of vision loss: the dawn of psychosomatic ophthalmology for preventive and personalized medicine.

    Science.gov (United States)

    Sabel, Bernhard A; Wang, Jiaqi; Cárdenas-Morales, Lizbeth; Faiq, Muneeb; Heim, Christine

    2018-06-01

    The loss of vision after damage to the retina, optic nerve, or brain has often grave consequences in everyday life such as problems with recognizing faces, reading, or mobility. Because vision loss is considered to be irreversible and often progressive, patients experience continuous mental stress due to worries, anxiety, or fear with secondary consequences such as depression and social isolation. While prolonged mental stress is clearly a consequence of vision loss, it may also aggravate the situation. In fact, continuous stress and elevated cortisol levels negatively impact the eye and brain due to autonomous nervous system (sympathetic) imbalance and vascular dysregulation; hence stress may also be one of the major causes of visual system diseases such as glaucoma and optic neuropathy. Although stress is a known risk factor, its causal role in the development or progression of certain visual system disorders is not widely appreciated. This review of the literature discusses the relationship of stress and ophthalmological diseases. We conclude that stress is both consequence and cause of vision loss. This creates a vicious cycle of a downward spiral, in which initial vision loss creates stress which further accelerates vision loss, creating even more stress and so forth. This new psychosomatic perspective has several implications for clinical practice. Firstly, stress reduction and relaxation techniques (e.g., meditation, autogenic training, stress management training, and psychotherapy to learn to cope) should be recommended not only as complementary to traditional treatments of vision loss but possibly as preventive means to reduce progression of vision loss. Secondly, doctors should try their best to inculcate positivity and optimism in their patients while giving them the information the patients are entitled to, especially regarding the important value of stress reduction. In this way, the vicious cycle could be interrupted. More clinical studies are now

  5. Modified Team-Based Learning in an Ophthalmology Clerkship in China.

    Directory of Open Access Journals (Sweden)

    Zheqian Huang

    Full Text Available Team-based learning (TBL is an increasingly popular teaching method in medical education. However, TBL hasn't been well-studied in the ophthalmology clerkship context. This study was to examine the impact of modified TBL in such context and to assess the student evaluations of TBL.Ninety-nine students of an 8-year clinical medicine program from Zhongshan Ophthalmic Centre, Sun Yat-sen University, were randomly divided into four sequential units and assigned to six teams with the same faculty. The one-week ophthalmology clerkship module included traditional lectures, gross anatomy and a TBL module. The effects of the TBL module on student performance were measured by the Individual Readiness Assurance Test (IRAT, the Group Readiness Assurance Test (GRAT, the Group Application Problem (GAP and final examination scores (FESs. Students' evaluations of TBL were measured by a 16-item questionnaire. IRAT and GRAT scores were compared using a paired t-test. One-way analysis of variance (ANOVA and subgroup analysis compared the effects among quartiles that were stratified by the Basic Ophthalmology Levels (BOLs. The BOLs were evaluated before the ophthalmology clerkship.In TBL classes, the GRAT scores were significantly higher than the IRAT scores in both the full example and the BOL-stratified groups. It highlighted the advantages of TBL compared to the individual learning. Quartile-stratified ANOVA comparisons showed significant differences at FES scores (P < 0.01. In terms to IRAT, GRAT and GAP scores, there was no significant result. Moreover, IRAT scores only significantly differed between the first and fourth groups. The FES scores of the first three groups are significantly higher than the fourth group. Gender-specific differences were significant in FES but not the IRAT. Overall, 57.65% of student respondents agreed that TBL was helpful. Male students tended to rate TBL higher than female students.The application of modified TBL to the

  6. Facing the challenges in ophthalmology clerkship teaching: Is flipped classroom the answer?

    Directory of Open Access Journals (Sweden)

    Ying Lin

    Full Text Available Recent reform of medical education highlights the growing concerns about the capability of the current educational model to equip medical school students with essential skills for future career development. In the field of ophthalmology, although many attempts have been made to address the problem of the decreasing teaching time and the increasing load of course content, a growing body of literature indicates the need to reform the current ophthalmology teaching strategies. Flipped classroom is a new pedagogical model in which students develop a basic understanding of the course materials before class, and use in-class time for learner-centered activities, such as group discussion and presentation. However, few studies have evaluated the effectiveness of the flipped classroom in ophthalmology education. This study, for the first time, assesses the use of flipped classroom in ophthalmology, specifically glaucoma and ocular trauma clerkship teaching. A total number of 44 international medical school students from diverse background were enrolled in this study, and randomly divided into two groups. One group took the flipped glaucoma classroom and lecture-based ocular trauma classroom, while the other group took the flipped ocular trauma classroom and lecture-based glaucoma classroom. In the traditional lecture-based classroom, students attended the didactic lecture and did the homework after class. In the flipped classroom, students were asked to watch the prerecorded lectures before the class, and use the class time for homework discussion. Both the teachers and students were asked to complete feedback questionnaires after the classroom. We found that the two groups did not show differences in the final exam scores. However, the flipped classroom helped students to develop skills in problem solving, creative thinking and team working. Also, compared to the lecture-based classroom, both teachers and students were more satisfied with the flipped

  7. Facing the challenges in ophthalmology clerkship teaching: Is flipped classroom the answer?

    Science.gov (United States)

    Lin, Ying; Zhu, Yi; Chen, Chuan; Wang, Wei; Chen, Tingting; Li, Tao; Li, Yonghao; Liu, Bingqian; Lian, Yu; Lu, Lin; Zou, Yuxian; Liu, Yizhi

    2017-01-01

    Recent reform of medical education highlights the growing concerns about the capability of the current educational model to equip medical school students with essential skills for future career development. In the field of ophthalmology, although many attempts have been made to address the problem of the decreasing teaching time and the increasing load of course content, a growing body of literature indicates the need to reform the current ophthalmology teaching strategies. Flipped classroom is a new pedagogical model in which students develop a basic understanding of the course materials before class, and use in-class time for learner-centered activities, such as group discussion and presentation. However, few studies have evaluated the effectiveness of the flipped classroom in ophthalmology education. This study, for the first time, assesses the use of flipped classroom in ophthalmology, specifically glaucoma and ocular trauma clerkship teaching. A total number of 44 international medical school students from diverse background were enrolled in this study, and randomly divided into two groups. One group took the flipped glaucoma classroom and lecture-based ocular trauma classroom, while the other group took the flipped ocular trauma classroom and lecture-based glaucoma classroom. In the traditional lecture-based classroom, students attended the didactic lecture and did the homework after class. In the flipped classroom, students were asked to watch the prerecorded lectures before the class, and use the class time for homework discussion. Both the teachers and students were asked to complete feedback questionnaires after the classroom. We found that the two groups did not show differences in the final exam scores. However, the flipped classroom helped students to develop skills in problem solving, creative thinking and team working. Also, compared to the lecture-based classroom, both teachers and students were more satisfied with the flipped classroom

  8. Ultraviolet-Visible and Fluorescence Spectroscopy Techniques Are Important Diagnostic Tools during the Progression of Atherosclerosis: Diet Zinc Supplementation Retarded or Delayed Atherosclerosis

    Science.gov (United States)

    Abdelhalim, Mohamed Anwar K.; Moussa, Sherif A. Abdelmottaleb; AL-Mohy, Yanallah Hussain

    2013-01-01

    Background. In this study, we examined whether UV-visible and fluorescence spectroscopy techniques detect the progression of atherosclerosis in serum of rabbits fed on high-cholesterol diet (HCD) and HCD supplemented with zinc (HCD + Zn) compared with the control. Methods. The control rabbits group was fed on 100 g/day of normal diet. The HCD group was fed on Purina Certified Rabbit Chow supplemented with 1.0% cholesterol plus 1.0% olive oil (100 g/day) for the same period. The HCD + Zn group was fed on normal Purina Certified Rabbit Chow plus 1.0% cholesterol and 1.0% olive oil supplemented with 470 ppm Zn for the same feeding period. UV-visible and fluorescence spectroscopy and biochemistry in Rabbit's blood serum and blood hematology were measured in Rabbit's blood. Results. We found that the fluorescent peak of HCD shifted toward UV-visible wavelength compared with the control using fluorescent excitation of serum at 192 nm. In addition, they showed that supplementation of zinc (350 ppm) restored the fluorescent peak closely to the control. By using UV-visible spectroscopy approach, we found that the peak absorbance of HCD (about 280 nm) was higher than that of control and that zinc supplementation seemed to decrease the absorbance. Conclusions. This study demonstrates that ultraviolet-visible and fluorescence spectroscopy techniques can be applied as noninvasive techniques on a sample blood serum for diagnosing or detecting the progression of atherosclerosis. The Zn supplementation to rabbits fed on HCD delays or retards the progression of atherosclerosis. Inducing anemia in rabbits fed on HCD delays the progression of atherosclerosis. PMID:24350281

  9. mHealth App for iOS to Help in Diagnostic Decision in Ophthalmology to Primary Care Physicians.

    Science.gov (United States)

    López, Marta Manovel; López, Miguel Maldonado; de la Torre Díez, Isabel; Jimeno, José Carlos Pastor; López-Coronado, Miguel

    2017-05-01

    Decision support systems (DSS) are increasingly demanded due that diagnosis is one of the main activities that physicians accomplish every day. This fact seems critical when primary care physicians deal with uncommon problems belonging to specialized areas. The main objective of this paper is the development and user evaluation of a mobile DSS for iOS named OphthalDSS. This app has as purpose helping in anterior segment ocular diseases' diagnosis, besides offering educative content about ophthalmic diseases to users. For the deployment of this work, firstly it has been used the Apple IDE, Xcode, to develop the OphthalDSS mobile application using Objective-C as programming language. The core of the decision support system implemented by OphthalDSS is a decision tree developed by expert ophthalmologists. In order to evaluate the Quality of Experience (QoE) of primary care physicians after having tried the OphthalDSS app, a written inquiry based on the Likert scale was used. A total of 50 physicians answered to it, after trying the app during 1 month in their medical consultation. OphthalDSS is capable of helping to make diagnoses of diseases related to the anterior segment of the eye. Other features of OphthalDSS are a guide of each disease and an educational section. A 70% of the physicians answered in the survey that OphthalDSS performs in the way that they expected, and a 95% assures their trust in the reliability of the clinical information. Moreover, a 75% of them think that the decision system has a proper performance. Most of the primary care physicians agree with that OphthalDSS does the function that they expected, it is a user-friendly and the contents and structure are adequate. We can conclude that OphthalDSS is a practical tool but physicians require extra content that makes it a really useful one.

  10. In-situ fluorimetry: A powerful non-invasive diagnostic technique for natural dyes used in artefacts. Part II. Identification of orcein and indigo in Renaissance tapestries

    Science.gov (United States)

    Clementi, C.; Miliani, C.; Romani, A.; Santamaria, U.; Morresi, F.; Mlynarska, K.; Favaro, G.

    2009-01-01

    In this paper, three Renaissance tapestries depicting scenes painted by Raffaello Sanzio, conserved at the Vatican Museum, were investigated using in-situ UV-Visible fluorimetric measurements. The results show that this technique is suitable for the detection of natural organic colorants used for dyeing the threads woven in these tapestries. The emission signals detected on red-purple colours were assigned to the colorant orcein and those on different nuances of blue and green colours to indigo by comparison with data from reference laboratory samples. The assignments were supported by chromatographic experiments carried out on threads taken from the back side of the tapestry in the same points analysed by spectrofluorimentry.

  11. Ophthalmologic Baseline Characteristics and 2-Year Ophthalmologic Safety Profile of Pramipexole IR Compared with Ropinirole IR in Patients with Early Parkinson’s Disease

    Directory of Open Access Journals (Sweden)

    William Seiple

    2016-01-01

    Full Text Available Background. Parkinson’s disease (PD progressively affects dopaminergic neurotransmission and may affect retinal dopaminergic functions and structures. Objective. This 2-year randomized, open-label, parallel-group, flexible-dose study, NCT00144300, evaluated ophthalmologic safety profiles of immediate-release (IR pramipexole and ropinirole in patients with early idiopathic PD with ≤6 months’ prior dopamine agonist exposure and without preexisting major eye disorders. Methods. Patients received labeled IR regimens of pramipexole (n=121 or ropinirole (n=125 for 2 years. Comprehensive ophthalmologic assessments (COA included corrected acuity, Roth 28-color test, slit-lamp biomicroscopy, intraocular pressure, computerized visual field test, fundus photography, and electroretinography. Results. At baseline, we observed retinal pigmentary epithelium (RPE hypopigmentation not previously reported in PD patients. The estimated relative risk of 2-year COA worsening with pramipexole versus ropinirole was 1.07 (95% CI: 0.71–1.60. Mean changes from baseline in Unified Parkinson’s Disease Rating System parts II+III total scores (pramipexole: 1 year, −4.1±8.9, and 2 years, −0.7±10.1, and ropinirole: 1 year, −3.7±8.2, and 2 years, −1.7±10.5 and Hoehn–Yahr stage distribution showed therapeutic effects on PD symptoms. Safety profiles were consistent with labeling. Conclusions. The risk of retinal deterioration did not differ in early idiopathic PD patients receiving pramipexole versus ropinirole. RPE hypopigmentation at baseline was not previously reported in this population. This trial is registered with NCT00144300.

  12. Diagnostic reproducibility of hydatidiform moles: ancillary techniques (p57 immunohistochemistry and molecular genotyping) improve morphologic diagnosis for both recently trained and experienced gynecologic pathologists.

    Science.gov (United States)

    Gupta, Mamta; Vang, Russell; Yemelyanova, Anna V; Kurman, Robert J; Li, Fanghong Rose; Maambo, Emily C; Murphy, Kathleen M; DeScipio, Cheryl; Thompson, Carol B; Ronnett, Brigitte M

    2012-12-01

    Distinction of hydatidiform moles from nonmolar specimens (NMs) and subclassification of hydatidiform moles as complete hydatidiform mole (CHM) and partial hydatidiform mole (PHM) are important for clinical practice and investigational studies; however, diagnosis based solely on morphology is affected by interobserver variability. Molecular genotyping can distinguish these entities by discerning androgenetic diploidy, diandric triploidy, and biparental diploidy to diagnose CHMs, PHMs, and NMs, respectively. Eighty genotyped cases (27 CHMs, 27 PHMs, 26 NMs) were selected from a series of 200 potentially molar specimens previously diagnosed using p57 immunohistochemistry and genotyping. Cases were classified by 6 pathologists (3 faculty level gynecologic pathologists and 3 fellows) on the basis of morphology, masked to p57 immunostaining and genotyping results, into 1 of 3 categories (CHM, PHM, or NM) during 2 diagnostic rounds; a third round incorporating p57 immunostaining results was also conducted. Consensus diagnoses (those rendered by 2 of 3 pathologists in each group) were also determined. Performance of experienced gynecologic pathologists versus fellow pathologists was compared, using genotyping results as the gold standard. Correct classification of CHMs ranged from 59% to 100%; there were no statistically significant differences in performance of faculty versus fellows in any round (P-values of 0.13, 0.67, and 0.54 for rounds 1 to 3, respectively). Correct classification of PHMs ranged from 26% to 93%, with statistically significantly better performance of faculty versus fellows in each round (P-values of 0.04, <0.01, and <0.01 for rounds 1 to 3, respectively). Correct classification of NMs ranged from 31% to 92%, with statistically significantly better performance of faculty only in round 2 (P-values of 1.0, <0.01, and 0.61 for rounds 1 to 3, respectively). Correct classification of all cases combined ranged from 51% to 75% by morphology and 70% to 80

  13. Vertical vs. transverse sections of scalp biopsy specimens: a pilot study on the comparison of the diagnostic value of two techniques in alopecia.

    Science.gov (United States)

    Özcan, D; Özen, Ö; Seçkin, D

    2011-12-01

    Using both vertical and transverse sections is preferred for histopathological diagnosis of alopecia. However, in cases in which only a single biopsy is taken, it is not clear which type of sectioning is better. To compare the diagnostic value of transverse and vertical sections. In total, 53 patients with alopecia were enrolled in the study. Two biopsies were taken from each patient, and cut into either transverse or vertical sections. The clinical and histopathological findings were evaluated together for the definitive diagnosis. After the study period, a pathologist randomly re-evaluated the sections. We compared the histopathological diagnoses with the definitive diagnoses, and determined the sensitivity and specificity of each method. A definitive diagnosis was made for 47 patients (88.7%). Of these, 30 (63.8%) had noncicatricial and 17 (36.2%) had cicatricial alopecia, and the diagnosis was made by transverse and vertical sections for 43 (91.5%) and 39 (88%), respectively (P > 0.05; sensitivity; 91.5% vs. 82%). All 30 patients with noncicatricial alopecia were diagnosed by transverse sections, and 25 (83.3%) of the 30 were diagnosed with vertical sections (P = 0.05; sensitivity 100% vs. 83.3%). Of the 17 patients with cicatricial alopecia, 13 (76.5%) and 14 (82.4%) patients were diagnosed by transverse and vertical sections, respectively (P > 0.05; sensitivity 76.5% vs. 82.4%). Five patients with lichen planopilaris were diagnosed by vertical sections, and one by transverse sections. There were several limitations to the study: (i) statistical subtype analysis could be performed only for alopecia areata; (ii) no conclusion could be drawn about the interobserver reliability of two sections; and (iii) having the pathologist-blinded study performed retrospectively might have caused a recall bias. If only a single biopsy specimen is available, it may be preferable to have transverse sections in cases of suspected noncicatricial alopecia, and vertical sections in

  14. Diagnostic accuracy of semi-quantitative and quantitative culture techniques for the diagnosis of catheter-related infections in newborns and molecular typing of isolated microorganisms.

    Science.gov (United States)

    Riboli, Danilo Flávio Moraes; Lyra, João César; Silva, Eliane Pessoa; Valadão, Luisa Leite; Bentlin, Maria Regina; Corrente, José Eduardo; Rugolo, Ligia Maria Suppo de Souza; da Cunha, Maria de Lourdes Ribeiro de Souza

    2014-05-22

    Catheter-related bloodstream infections (CR-BSIs) have become the most common cause of healthcare-associated bloodstream infections in neonatal intensive care units (ICUs). Microbiological evidence implicating catheters as the source of bloodstream infection is necessary to establish the diagnosis of CR-BSIs. Semi-quantitative culture is used to determine the presence of microorganisms on the external catheter surface, whereas quantitative culture also isolates microorganisms present inside the catheter. The main objective of this study was to determine the sensitivity and specificity of these two techniques for the diagnosis of CR-BSIs in newborns from a neonatal ICU. In addition, PFGE was used for similarity analysis of the microorganisms isolated from catheters and blood cultures. Semi-quantitative and quantitative methods were used for the culture of catheter tips obtained from newborns. Strains isolated from catheter tips and blood cultures which exhibited the same antimicrobial susceptibility profile were included in the study as positive cases of CR-BSI. PFGE of the microorganisms isolated from catheters and blood cultures was performed for similarity analysis and detection of clones in the ICU. A total of 584 catheter tips from 399 patients seen between November 2005 and June 2012 were analyzed. Twenty-nine cases of CR-BSI were confirmed. Coagulase-negative staphylococci (CoNS) were the most frequently isolated microorganisms, including S. epidermidis as the most prevalent species (65.5%), followed by S. haemolyticus (10.3%), yeasts (10.3%), K. pneumoniae (6.9%), S. aureus (3.4%), and E. coli (3.4%). The sensitivity of the semi-quantitative and quantitative techniques was 72.7% and 59.3%, respectively, and specificity was 95.7% and 94.4%. The diagnosis of CR-BSIs based on PFGE analysis of similarity between strains isolated from catheter tips and blood cultures showed 82.6% sensitivity and 100% specificity. The semi-quantitative culture method showed higher

  15. Revolutionary introduction of RIA/IRMA methodology in medical diagnostics: a study employing the technique for hyperprolactinemia and its correlation with hypothyroidism

    International Nuclear Information System (INIS)

    Tasneem, A.

    2011-01-01

    The aim of the study was to determine the incidence of hyperprolactinemia, its underlying causes and consequences, and to study its correlation with hypothyroidism. The study was carried out on 1365 male and female subjects referred to Centre for Nuclear Medicine Lahore for hormonal estimation. Serum Prolactin and thyroid stimulating hormone (TSH) levels were measured using IRMA kits. Prevalence of hyperprolactinemia turned out to be 4.90%. Menstrual irregularity appeared as a major consequence. The incidence rate was the highest in the age range of 21-27 years. Hypothyroidism in hyperprolactinemic subjects was observed to be 22.7%. i) Immunoradiometric assay is a micro analytical technique which can measure very minute amount of the antigens in the serum. II) Prevalence of hypothyroidism in hyperprolactinemic subjects in our population is promising enough to estimate thyroid hormone levels in hyperprolactinemic patients. (author)

  16. Metabolomics for laboratory diagnostics.

    Science.gov (United States)

    Bujak, Renata; Struck-Lewicka, Wiktoria; Markuszewski, Michał J; Kaliszan, Roman

    2015-09-10

    Metabolomics is an emerging approach in a systems biology field. Due to continuous development in advanced analytical techniques and in bioinformatics, metabolomics has been extensively applied as a novel, holistic diagnostic tool in clinical and biomedical studies. Metabolome's measurement, as a chemical reflection of a current phenotype of a particular biological system, is nowadays frequently implemented to understand pathophysiological processes involved in disease progression as well as to search for new diagnostic or prognostic biomarkers of various organism's disorders. In this review, we discussed the research strategies and analytical platforms commonly applied in the metabolomics studies. The applications of the metabolomics in laboratory diagnostics in the last 5 years were also reviewed according to the type of biological sample used in the metabolome's analysis. We also discussed some limitations and further improvements which should be considered taking in mind potential applications of metabolomic research and practice. Copyright © 2014 Elsevier B.V. All rights reserved.

  17. Creation of an Accurate Algorithm to Detect Snellen Best Documented Visual Acuity from Ophthalmology Electronic Health Record Notes.

    Science.gov (United States)

    Mbagwu, Michael; French, Dustin D; Gill, Manjot; Mitchell, Christopher; Jackson, Kathryn; Kho, Abel; Bryar, Paul J

    2016-05-04

    Visual acuity is the primary measure used in ophthalmology to determine how well a patient can see. Visual acuity for a single eye may be recorded in multiple ways for a single patient visit (eg, Snellen vs. Jäger units vs. font print size), and be recorded for either distance or near vision. Capturing the best documented visual acuity (BDVA) of each eye in an individual patient visit is an important step for making electronic ophthalmology clinical notes useful in research. Currently, there is limited methodology for capturing BDVA in an efficient and accurate manner from electronic health record (EHR) notes. We developed an algorithm to detect BDVA for right and left eyes from defined fields within electronic ophthalmology clinical notes. We designed an algorithm to detect the BDVA from defined fields within 295,218 ophthalmology clinical notes with visual acuity data present. About 5668 unique responses were identified and an algorithm was developed to map all of the unique responses to a structured list of Snellen visual acuities. Visual acuity was captured from a total of 295,218 ophthalmology clinical notes during the study dates. The algorithm identified all visual acuities in the defined visual acuity section for each eye and returned a single BDVA for each eye. A clinician chart review of 100 random patient notes showed a 99% accuracy detecting BDVA from these records and 1% observed error. Our algorithm successfully captures best documented Snellen distance visual acuity from ophthalmology clinical notes and transforms a variety of inputs into a structured Snellen equivalent list. Our work, to the best of our knowledge, represents the first attempt at capturing visual acuity accurately from large numbers of electronic ophthalmology notes. Use of this algorithm can benefit research groups interested in assessing visual acuity for patient centered outcome. All codes used for this study are currently available, and will be made available online at https://phekb.org.

  18. GENERAL OPHTHALMOLOGY

    African Journals Online (AJOL)

    of trauma, extent of eye injury, and visual acuity (VA) at admission and the time of discharge. .... history of poor vision affecting both distant and near, difficulty reading .... the field while avoiding superlatives or self-aggrandizing phrases. Your.

  19. COMMUNITY OPHTHALMOLOGY

    African Journals Online (AJOL)

    2016-11-04

    Nov 4, 2016 ... The Role of Research in Social Marketing: The Community Eye. Outreach Clinic .... Serious thought was given to the possibility of establishing static eye care .... Information obtained included vital statistics, work history, job.

  20. GENERAL OPHTHALMOLOGY

    African Journals Online (AJOL)

    2016-11-04

    Nov 4, 2016 ... Nelson-Immu JC, Mowatt L, Walters C.A. Patterns of ocular trauma presenting to the ... 11 hospital, Addis Ababa. Ethiop J Health Dev 2001;15:131-7. 12. ... injuries in Irrua Specialist Teaching Hospital, Irrua, Edo State Nigeria.