WorldWideScience

Sample records for diagnostic port plug

  1. Engineering activities on the ITER representative diagnostic equatorial port plug

    International Nuclear Information System (INIS)

    Meunier, L.; Doceul, L.; Salasca, S.; Martins, J.-P.; Jullien, F.; Dechelle, Christian; Bidaud, Pierre; Pilard, Vincent; Terra, Alexis; Ogea, Mathieu; Ciattaglia, Emanuela; Walker, Christopher

    2009-01-01

    Most of ITER diagnostic systems are integrated in port plugs, which are water cooled stainless steel structures inserted into the vacuum vessel ports. The port plug must provide basic functions such as neutron and gamma shielding, supporting the first wall armour (BSM), closing the vacuum vessel ports, while supporting the diagnostic equipments. ITER diagnostic port plug must resist a severe environment like high temperature due to neutron interaction with the structures and high electromechanical loading during disruptions events. CEA has contributed to the design and integration tasks in the frame of the representative equatorial port plug EQ no. 01, in particular on the engineering, structural and thermal finite element analysis. These detailed analyses have highlighted some design issues which were worked out through different solutions. This paper contains a description of the engineering activities performed such as: -The static mechanical calculations of the top plate closure system under disruption load. -The static mechanical calculations of the BSM attachment to the port plug. These two first studies led to design changes proposals which significantly improved the behaviour of the structures but also showed that the safety margin with respect to design limits is quite low. -The design of a Diagnostic Shield Module (DSM) integrated inside the port plug and a proposition of attachment scheme, with respect to disruption loads. The manufacturing of the DSM has been taken into account, as well as diagnostic integration inside the structure and maintenance aspects. -The thermal assessment of the port plug under neutronic load during normal operation, with the optimization of the cooling system. The maximum temperature calculated in normal operation has been reduced from 900 deg. C to less than 400 deg. C in the front plate; and the cooling arrangement at the back of the port plug has been simplified without important temperature increase.

  2. Engineering activities on the ITER representative diagnostic equatorial port plug

    Energy Technology Data Exchange (ETDEWEB)

    Meunier, L. [Association Euratom CEA, CEA/DSM/IRFM (France)], E-mail: lmeunier@cea.fr; Doceul, L.; Salasca, S.; Martins, J.-P.; Jullien, F.; Dechelle, Christian; Bidaud, Pierre; Pilard, Vincent; Terra, Alexis; Ogea, Mathieu [Association Euratom CEA, CEA/DSM/IRFM (France); Ciattaglia, Emanuela [EFDA CSU, Garching (Germany); Walker, Christopher [ITER International Organisation (France)

    2009-06-15

    Most of ITER diagnostic systems are integrated in port plugs, which are water cooled stainless steel structures inserted into the vacuum vessel ports. The port plug must provide basic functions such as neutron and gamma shielding, supporting the first wall armour (BSM), closing the vacuum vessel ports, while supporting the diagnostic equipments. ITER diagnostic port plug must resist a severe environment like high temperature due to neutron interaction with the structures and high electromechanical loading during disruptions events. CEA has contributed to the design and integration tasks in the frame of the representative equatorial port plug EQ no. 01, in particular on the engineering, structural and thermal finite element analysis. These detailed analyses have highlighted some design issues which were worked out through different solutions. This paper contains a description of the engineering activities performed such as: -The static mechanical calculations of the top plate closure system under disruption load. -The static mechanical calculations of the BSM attachment to the port plug. These two first studies led to design changes proposals which significantly improved the behaviour of the structures but also showed that the safety margin with respect to design limits is quite low. -The design of a Diagnostic Shield Module (DSM) integrated inside the port plug and a proposition of attachment scheme, with respect to disruption loads. The manufacturing of the DSM has been taken into account, as well as diagnostic integration inside the structure and maintenance aspects. -The thermal assessment of the port plug under neutronic load during normal operation, with the optimization of the cooling system. The maximum temperature calculated in normal operation has been reduced from 900 deg. C to less than 400 deg. C in the front plate; and the cooling arrangement at the back of the port plug has been simplified without important temperature increase.

  3. Generic Diagnostic Port Integration for the Equatorial Port Plug of ITER

    International Nuclear Information System (INIS)

    Doceul, L.; Chappuis, Ph.; Portafaix, Ch.; Guillaume, T.; Bruyere, Ch.; Walker, Ch.; Ingesson, Ch.; Ciattaglia, E.; Salasca, S.; Eric, T.

    2006-01-01

    ITER requires an extensive set of diagnostic systems to provide several key functions such as protection of the device, input to plasma control systems and evaluation of the plasma performance. Most of these diagnostics system are to be integrated in port plugs, which are water cooled stainless steel structures (approximately: 50 t, 2 m x 2 m x 4 m) inserted into the vacuum-vessel ports. The port plug must perform basic functions such as providing neutron and gamma shielding, supporting the first wall armour and shielding blanket material, closing the vacuum vessel ports, supporting the diagnostic equipment (within the primary vacuum, on the primary vacuum boundary and in the port interspace). CEA (Commissariat l'Energie Atomique) has contributed to the engineering activities on the port plugs and has more particularly focused on the design and diagnostic integration in the representative equatorial port plug EQ01. The specific CEA contributions were to perform the general engineering, structural and thermal analysis. These detailed analysis have highlighted some design issues which were worked out through different solutions. This paper will contain the description of the engineering activities performed such as: - The conceptual design of the EQ01 and the associated diagnostics, such as the visible and infrared optical diagnostic, - The static mechanical calculations, taking into account the electromagnetic loads occurring during fast transient plasma events, - The dynamic calculation constituted of modal and transient analysis under the same electromagnetic loads to estimate the dynamic amplification factor due to the resonance phenomenon, - The thermal assessment under the neutronic load of the water-cooled stainless steel structure, - The seismic response of the port plug inside the vacuum vessel, taking into account the ground spectra and soil conditions in the Cadarache site. (author)

  4. Numerical simulation on bake-out of the ITER diagnostic upper port plug

    International Nuclear Information System (INIS)

    Pak, S.; Pitcher, C.S.; Kalish, M.R.; Cheon, M.S.; Seon, C.R.; Lee, H.G.

    2010-01-01

    The diagnostic upper port plug in ITER is fixed to the upper port of the vacuum vessel as a cantilevered beam with bolts and forms a primary vacuum boundary. It needs to be baked out for outgassing before normal operation. This study calculated the required bake-out time and the transient thermal stress during baking for the diagnostic upper port plug. The calculation was done through numerical simulation. The analysis took into consideration the gradual temperature increase of working fluid. In order to look into the effect of radiation heat transfer from the upper port plug to the vacuum vessel port, the upper vacuum vessel port was included in this analysis.

  5. Results of an integration study of a diagnostics port plug in ITER

    International Nuclear Information System (INIS)

    Salasca, Sophie; Cantone, Bruno; Grosman, André; Esposito, Basilio; Moro, Fabio; Morocco, Daniele; Villari, Rosaria; Angelone, Maurizio; Rincon, Esther; Hidalgo, Carlos; Nagy, Daniel; Kocsis, Gabor; Varela, Paulo; Porempovics, Gabor; Perrollaz, Guillaume; Patel, Kunal; Krivchenkov, Yuri; Walsh, Michael

    2013-01-01

    Highlights: ► An extensive study on the integration of diagnostics in a port plug of ITER has been performed. ► It has shown that the diagnostic performances could not be reached if their number was not decreased. ► A design of Diagnostic Shield Modules has been validated through mechanical and thermal analyses. ► These analyses have confirmed that the highest loads are concentrated in the vicinity of the plasma. -- Abstract: Diagnostics in ITER are mandatory to characterize the parameters of plasma and study its interactions with plasma-facing components. Diagnostics components in the vicinity of the plasma are supported by metallic structures called port plugs. At the tokamak mid-plane, these components are installed in port plugs through intermediate structures called drawers. Apart from hosting the diagnostics, the port plugs act as shielding against neutrons and gammas, in order to limit the nuclear loads in crucial components (such as diagnostics and superconducting coils) as well as the dose levels in the controlled zones of the tokamak. The radiation shielding function of the port plugs is ensured through an optimized mixture of heavy metallic materials and water, forming shielding blocks surrounding the diagnostics and called Diagnostic Shield Modules (DSMs). These DSMs constitute the rear part of the drawers (the front part being composed of the Diagnostic First Wall). This paper presents the main results of a study performed in Europe on the integration of a particular diagnostics port plug, the Equatorial Port Plug 1 (EPP1). The paper first provides the results of the EPP1 diagnostics integration analysis. In a second step it focuses on the design of the EPP1 DSMs and summarizes the major results of a thorough set of analyses aiming at studying the DSMs behaviour under different loads, suggesting recommendations to improve their current design

  6. CEA engineering studies and integration of the ITER diagnostic port plugs

    International Nuclear Information System (INIS)

    Doceul, L.; Walker, C.; Ingesson, C.; Ciattaglia, E.; Chappuis, P.; Portafaix, C.; Salasca, S.; Thomas, E.; Tremblay, G.; Bruyere, C.

    2007-01-01

    Most of the ITER diagnostic system is integrated in port plugs, which are water cooled stainless steel structures inserted into the vacuum-vessel ports. The port plug must perform basic functions such as providing neutron and gamma shielding, supporting the first wall armour and shielding blanket material, closing the vacuum vessel ports, while supporting the diagnostic equipment. CEA has contributed to the engineering activities on the port plugs and has more particularly focused on the design and diagnostic integration in the representative equatorial port plug Eq no. 01. The specific CEA contributions have been the engineering, structural and thermal analysis. These detailed analyses have highlighted some design issues which were worked out through different solutions. This paper contains a description of the engineering activities performed such as: the conceptual design of the Eq no. 01 port plug, the static mechanical calculations, the dynamic calculation to estimate the dynamic amplification factor due to the resonance phenomenon, the thermal assessment under the neutronic load and the seismic response of the port plug inside the vacuum vessel

  7. CEA engineering studies and integration of the ITER diagnostic port plugs

    Energy Technology Data Exchange (ETDEWEB)

    Doceul, L. [Association Euratom-CEA sur la Fusion Controlee, Centre d' Etudes de Cadarache, F-13108 Saint-Paul-Lez-Durance Cedex (France)], E-mail: louis.doceul@cea.fr; Walker, C. [ITER International Team, Boltzmannstr. 2, D-85748 Garching bei Muenchen (Germany); Ingesson, C.; Ciattaglia, E. [EFDA CSU - Garching, Boltzmannstr. 2, D-85748 Garching bei Muenchen (Germany); Chappuis, P.; Portafaix, C.; Salasca, S.; Thomas, E.; Tremblay, G.; Bruyere, C. [Association Euratom-CEA sur la Fusion Controlee, Centre d' Etudes de Cadarache, F-13108 Saint-Paul-Lez-Durance Cedex (France)

    2007-10-15

    Most of the ITER diagnostic system is integrated in port plugs, which are water cooled stainless steel structures inserted into the vacuum-vessel ports. The port plug must perform basic functions such as providing neutron and gamma shielding, supporting the first wall armour and shielding blanket material, closing the vacuum vessel ports, while supporting the diagnostic equipment. CEA has contributed to the engineering activities on the port plugs and has more particularly focused on the design and diagnostic integration in the representative equatorial port plug Eq no. 01. The specific CEA contributions have been the engineering, structural and thermal analysis. These detailed analyses have highlighted some design issues which were worked out through different solutions. This paper contains a description of the engineering activities performed such as: the conceptual design of the Eq no. 01 port plug, the static mechanical calculations, the dynamic calculation to estimate the dynamic amplification factor due to the resonance phenomenon, the thermal assessment under the neutronic load and the seismic response of the port plug inside the vacuum vessel.

  8. Electromagnetic analysis of ITER diagnostic equatorial port plugs during plasma disruptions

    International Nuclear Information System (INIS)

    Zhai, Y.; Feder, R.; Brooks, A.; Ulrickson, M.; Pitcher, C.S.; Loesser, G.D.

    2013-01-01

    Highlights: ► Disruption loads on ITER diagnostic equatorial port plugs are extracted. ► Upward major disruption produces the largest radial moment and radial force on diagnostic first walls and diagnostic shield modules. ► Large eddy currents on supporting rails, keys and water pipes are observed during disruption. -- Abstract: ITER diagnostic port plugs perform many functions including structural support of diagnostic systems under high electromagnetic loads while allowing for diagnostic access to the plasma. The design of diagnostic equatorial port plugs (EPP) are largely driven by electromagnetic loads and associate responses of EPP structure during plasma disruptions and VDEs. This paper summarizes results of transient electromagnetic analysis using Opera 3d in support of the design activities for ITER diagnostic EPP. A complete distribution of disruption loads on the diagnostic first walls (DFWs), diagnostic shield modules (DSMs) and the EPP structure, as well as impact on the system design integration due to electrical contact among various EPP structural components are discussed

  9. Final design of the generic equatorial port plug structure for ITER diagnostic systems

    International Nuclear Information System (INIS)

    Udintsev, V.S.; Maquet, P.; Alexandrov, E.; Casal, N.; Cuenca, D.; Drevon, J.-M.; Feder, R.; Friconneau, J.P.; Giacomin, T.; Guirao, J.; Iglesias, S.; Josseaume, F.; Levesy, B.; Loesser, D.; Ordieres, J.; Quinn, E.; Pak, S.; Penot, C.; Pitcher, C.S.; Portalès, M.

    2015-01-01

    The Diagnostic Generic Equatorial Port Plug (GEPP) is designed to be common to all equatorial port-based diagnostic systems. It is designed to survive throughout the lifetime of ITER for 20 years, 30,000 discharges, and 3000 disruptions. The EPP structure dimensions (without Diagnostic First Walls and Diagnostic Shield Modules) are L2.9 × W1.9 × H2.4 m"3. The length of the fully integrated EPP is 3174 mm. The weight of the EPP structure is about 15 t, whereas the total weight of the integrated EPP may be up to 45 t. The EPP structure provides a flexible platform for a variety of diagnostics. The Diagnostic Shield Module assemblies, or drawers, allow a modular approach with respect to diagnostic integration and maintenance. In the nuclear phase of ITER operations, they will be remotely inserted into the EPP structure in the Hot Cell Facility. The port plug structure must also contribute to the nuclear shielding, or plugging, of the port and further contain circulated water to allow cooling during operation and heating during bake-out. The Final Design of the GEPP has been successfully passed in late 2013 and is now heading toward manufacturing. The final design of the GEPP includes interfaces, manufacturing, R&D, operation and maintenance, load cases and analysis of failure modes.

  10. Final design of the generic upper port plug structure for ITER diagnostic systems

    Energy Technology Data Exchange (ETDEWEB)

    Pak, Sunil, E-mail: paksunil@nfri.re.kr [National Fusion Research Institute, Daejeon (Korea, Republic of); Feder, Russell [Princeton Plasma Physics Laboratory, Princeton, NJ (United States); Giacomin, Thibaud; Guirao, Julio; Iglesias, Silvia; Josseaume, Fabien [ITER Organization, Route de Vinon sur Verdon, 13115 St Paul-lez-Durance (France); Kalish, Michael; Loesser, Douglas [Princeton Plasma Physics Laboratory, Princeton, NJ (United States); Maquet, Philippe [ITER Organization, Route de Vinon sur Verdon, 13115 St Paul-lez-Durance (France); Ordieres, Javier; Panizo, Marcos [NATEC, Ingenieros, Gijón (Spain); Pitcher, Spencer; Portalès, Mickael [ITER Organization, Route de Vinon sur Verdon, 13115 St Paul-lez-Durance (France); Proust, Maxime [CEA, Cadarache, St. Paul-lez-Durance (France); Ronden, Dennis [FOM Institute DIFFER, Nieuwegein (Netherlands); Serikov, Arkady [Karlsruhe Institute of Technology, Eggenstein-Leopoldshafen (Germany); Suarez, Alejandro [ITER Organization, Route de Vinon sur Verdon, 13115 St Paul-lez-Durance (France); Tanchuk, Victor [NIIEFA, St.-Petersburg (Russian Federation); Udintsev, Victor; Vacas, Christian [ITER Organization, Route de Vinon sur Verdon, 13115 St Paul-lez-Durance (France); and others

    2016-01-15

    The generic upper port plug (GUPP) structure in ITER is a 6 m long metal box which deploys diagnostic components into the vacuum vessel. This structure is commonly used for all the diagnostic upper ports. The final design of the GUPP structure, which has successfully passed the final design review in 2013, is described here. The diagnostic port plug is cantilevered to the vacuum vessel with a heavy payload at the front, so called the diagnostic first wall (DFW) and the diagnostic shield module (DSM). Most of electromagnetic (EM) load (∼80%) occurs in DFW/DSM. Therefore, the mounting design to transfer the EM load from DFW/DSM to the GUPP structure is challenging, which should also comply with thermal expansion and tolerance for assembly and manufacturing. Another key design parameter to be considered is the gap between the port plug and the vacuum vessel port. The gap should be large enough to accommodate the remote handling of the heavy port plug (max. 25 t), the structural deflection due to external loads and machine assembly tolerance. At the same time, the gap should be minimized to stop the neutron streaming according to the ALARA (as low as reasonably achievable) principle. With these design constraints, the GUPP structure should also provide space for diagnostic integration as much as possible. This requirement has led to the single wall structure having the gun-drilled water channels inside the structure. Furthermore, intensive efforts have been made on the manufacturing study including material selection, manufacturing codes and French regulation related to nuclear equipment and safety. All these main design and manufacturing aspects are discussed in this paper, including requirements, interfaces, loads and structural assessment and maintenance.

  11. Evaluation of electromagnetic loads on various design options of the ITER diagnostic upper port plug during plasma disruptions

    International Nuclear Information System (INIS)

    Pak, Sunil; Ku, Duck Young; Oh, Dong-Keun; Jhang, Hogun; Kim, Duck-Hoi; Cheon, Mun-Seong; Seon, Chang Rae; Lee, Hyeon Gon; Pitcher, Spencer

    2011-01-01

    Electromagnetic (EM) loads due to eddy current and halo current during plasma disruptions are evaluated for the ITER diagnostic upper port plug. To reduce strong EM loads acting on the port plug fixed to the vacuum vessel like a cantilever beam, three design options have been considered: removal of the diagnostic first wall, slitting of the diagnostic shield module and recess of the port plug. The main focus of the present study is to examine the efficacy of these options in terms of EM loads on the upper port plug. It is found that making slits is more effective than removing the first wall. It is also shown that the upper port plug needs to be recessed to reduce the EM load induced by halo current.

  12. ITER Generic Diagnostic Upper Port Plug Nuclear Heating and Personnel Dose Rate Assessment

    International Nuclear Information System (INIS)

    Feder, Russell E.; Youssef, Mahmoud Z.

    2009-01-01

    Neutronics analysis to find nuclear heating rates and personnel dose rates were conducted in support of the integration of diagnostics in to the ITER Upper Port Plugs. Simplified shielding models of the Visible-Infrared diagnostic and of a large aperture diagnostic were incorporated in to the ITER global CAD model. Results for these systems are representative of typical designs with maximum shielding and a small aperture (Vis-IR) and minimal shielding with a large aperture. The neutronics discrete-ordinates code ATTILA(reg s ign) and SEVERIAN(reg s ign) (the ATTILA parallel processing version) was used. Material properties and the 500 MW D-T volume source were taken from the ITER 'Brand Model' MCNP benchmark model. A biased quadrature set equivalent to Sn=32 and a scattering degree of Pn=3 were used along with a 46-neutron and 21-gamma FENDL energy subgrouping. Total nuclear heating (neutron plug gamma heating) in the upper port plugs ranged between 380 and 350 kW for the Vis-IR and Large Aperture cases. The Large Aperture model exhibited lower total heating but much higher peak volumetric heating on the upper port plug structure. Personnel dose rates are calculated in a three step process involving a neutron-only transport calculation, the generation of activation volume sources at pre-defined time steps and finally gamma transport analyses are run for selected time steps. ANSI-ANS 6.1.1 1977 Flux-to-Dose conversion factors were used. Dose rates were evaluated for 1 full year of 500 MW DT operation which is comprised of 3000 1800-second pulses. After one year the machine is shut down for maintenance and personnel are permitted to access the diagnostic interspace after 2-weeks if dose rates are below 100 (micro)Sv/hr. Dose rates in the Visible-IR diagnostic model after one day of shutdown were 130 (micro)Sv/hr but fell below the limit to 90 (micro)Sv/hr 2-weeks later. The Large Aperture style shielding model exhibited higher and more persistent dose rates. After 1

  13. Laser welding and ablation cutting process for hydraulic connections by remote handling in the ITER diagnostic port plug

    International Nuclear Information System (INIS)

    Pak, S.; Kim, Y.; Park, K.Y.; Lee, K.D.; Cheon, M.S.; Lee, H.G.

    2010-01-01

    To assess hydraulic connections between subcomponents of the International Thermonuclear Experimental Reactor (ITER) diagnostic port plug, we investigated the laser welding and ablation cutting process, which can be applied to remote handling maintenance. In this study, laser ablation cutting, which vaporizes a small amount of solid material directly into gas by focusing a laser beam of high-density energy, is adopted in order to overcome the limitation of the normal laser cutting technology that the head should be placed as close to the work piece as possible to blow out melt metal at a distance. Complete cutting of a work piece is obtained by repetitive multi-passes of the laser beam. The welding and cutting process were tested on the sample work pieces and finally on a prototype of a hydraulic connection module for remote handling. The results showed that this process can be a promising candidate for hydraulic connections by remote handling. Furthermore the design of the hydraulic connection module has been updated to resolve some technical difficulties that were found during the test.

  14. Laser welding and ablation cutting process for hydraulic connections by remote handling in the ITER diagnostic port plug

    Energy Technology Data Exchange (ETDEWEB)

    Pak, S. [National Fusion Research Institute, 52 Eoeun-dong, Yuseong-gu, Daejeon (Korea, Republic of)], E-mail: paksunil@nfri.re.kr; Kim, Y.; Park, K.Y.; Lee, K.D. [Institute for Advanced Engineering, 633-2, Goan-ri, Baegam-myeon, Cheoin-gu, Yongin-si, Gyeonggi-do (Korea, Republic of); Cheon, M.S.; Lee, H.G. [National Fusion Research Institute, 52 Eoeun-dong, Yuseong-gu, Daejeon (Korea, Republic of)

    2010-04-15

    To assess hydraulic connections between subcomponents of the International Thermonuclear Experimental Reactor (ITER) diagnostic port plug, we investigated the laser welding and ablation cutting process, which can be applied to remote handling maintenance. In this study, laser ablation cutting, which vaporizes a small amount of solid material directly into gas by focusing a laser beam of high-density energy, is adopted in order to overcome the limitation of the normal laser cutting technology that the head should be placed as close to the work piece as possible to blow out melt metal at a distance. Complete cutting of a work piece is obtained by repetitive multi-passes of the laser beam. The welding and cutting process were tested on the sample work pieces and finally on a prototype of a hydraulic connection module for remote handling. The results showed that this process can be a promising candidate for hydraulic connections by remote handling. Furthermore the design of the hydraulic connection module has been updated to resolve some technical difficulties that were found during the test.

  15. Final design of ITER port plug test facility

    Energy Technology Data Exchange (ETDEWEB)

    Cerisier, Thierry, E-mail: thierry.cerisier@yahoo.fr [ITER Organization, Route de Vinon-sur-Verdon, CS 90046, St Paul-lez-Durance Cedex, 13067 (France); Levesy, Bruno [ITER Organization, Route de Vinon-sur-Verdon, CS 90046, St Paul-lez-Durance Cedex, 13067 (France); Romannikov, Alexander [Institution “Project Center ITER”, Kurchatov sq. 1, Building 3, Moscow 123182 (Russian Federation); Rumyantsev, Yuri [JSC “Cryogenmash”, Moscow reg., Balashikha 143907 (Russian Federation); Cordier, Jean-Jacques; Dammann, Alexis [ITER Organization, Route de Vinon-sur-Verdon, CS 90046, St Paul-lez-Durance Cedex, 13067 (France); Minakov, Victor; Rosales, Natalya; Mitrofanova, Elena [JSC “Cryogenmash”, Moscow reg., Balashikha 143907 (Russian Federation); Portone, Sergey; Mironova, Ekaterina [Institution “Project Center ITER”, Kurchatov sq. 1, Building 3, Moscow 123182 (Russian Federation)

    2016-11-01

    Highlights: • We introduce the port plug test facility (purpose and status of the design). • We present the PPTF sub-systems. • We present the environmental and functional tests. • We present the occupational and nuclear safety functions. • We conclude on the achievements and next steps. - Abstract: To achieve the overall ITER machine availability target, the availability of diagnostics and heating port plugs shall be as high as 99.5%. To fulfill this requirement, it is mandatory to test the port plugs at operating temperature before installation on the machine and after refurbishment. The ITER port plug test facility (PPTF) is composed of several test stands that can be used to test the port plugs whereas at the end of manufacturing (in a non-nuclear environment), or after refurbishment in the ITER hot cell facility. The PPTF provides the possibility to perform environmental (leak tightness, vacuum and thermo-hydraulic performances) and functional tests (radio frequency acceptance tests, behavior of the plugs’ steering mechanism and calibration of diagnostics) on upper and equatorial port plugs. The final design of the port plug test facility is described. The configuration of the standalone test stands and the integration in the hot cell facility are presented.

  16. A conceptual design of the ITER upper port plug structure and its cooling channels

    International Nuclear Information System (INIS)

    Pak, S.I.; Lee, H.G.; Jung, K.J.; Walker, C.I.; Kim, D.G.; Choi, K.S.

    2008-01-01

    A study is conducted on the conceptual design of the structure and cooling channels of the upper port plug of International Thermonuclear Experimental Reactor (ITER). Modification of the earlier port plug design is made and a simple fabrication method is proposed. It is shown that the newly designed port plug can accommodate the installation of both diagnostic and electron cyclotron heating (ECH) devices. Design assessment is carried out through structural and thermo-hydraulic analyses. Results of the analyses show that the port plug structure is stable against one of the most severe plasma events and the total pressure drop of the coolant is within the allowable level

  17. Remote Handling behind port plug in ITER

    International Nuclear Information System (INIS)

    Bede, O.; Neuberger, H.

    2006-01-01

    Different Test Blanket Modules (TBM) will be used in succession in the same equatorial ports of ITER. The remote handling operations for connection/disconnection of an interface between the port plug of the EU-HCPB-TBM and the port cell equipment are investigated with the goal to reach a quick and simple TBM exchange procedure. This paper describes the operations and systems which are required for connection of the TBM to its supply lines at this interface. The interface is located inside the free space of the port plug flange between the port plug shield and the bioshield of the port cell behind. The approach of the operation place is only available through a narrow gate in the bioshield opened temporarily during maintenance periods. This gate limits the dimensions of the whole system and its tools. The current design of the EU-HCPB-TBM foresees up to 9 supply lines which have to be connected inside the free space of one half of the port plug flange. The connection operations require positioning and adjustment of the tools for each pipe separately. Despite the strict circumstances it is still possible to find such an industrial jointed-arm robot with sufficient payload, which can penetrate into the working area. A mechanical system is necessary to move the robot from its storing place in the hot cell to the port plug on 6 m distance. Each operation requires different end-of-arm tools. The most special one is a pipe positioner tool, which can position and pull the pipe ends to each other and align the tool before welding and hold them in proper position during the welding process. Weld seams can be made by orbital welding tool. The pipe positioner tool has to provide place for welding tool. Using of inbore tool is impossible because pipes have no open ends where the tool could leave it. Orbital tool must be modified to meet requirements of remote handling because it is designed for human handling. The coolant is helium, so for eliminating the leak of helium it is

  18. DEMO port plug design and integration studies

    Science.gov (United States)

    Grossetti, G.; Boccaccini, L. V.; Cismondi, F.; Del Nevo, A.; Fischer, U.; Franke, T.; Granucci, G.; Hernández, F.; Mozzillo, R.; Strauß, D.; Tran, M. Q.; Vaccaro, A.; Villari, R.

    2017-11-01

    The EUROfusion Consortium established in 2014 and composed by European Fusion Laboratories, and in particular the Power Plant Physics and Technology department aims to develop a conceptual design for the Fusion DEMOnstration Power Plant, DEMO. With respect to present experimental machines and ITER, the main goals of DEMO are to produce electricity continuously for a period of about 2 h, with a net electrical power output of a few hundreds of MW, and to allow tritium self-sufficient breeding with an adequately high margin in order to guarantee its planned operational schedule, including all planned maintenance intervals. This will eliminate the need to import tritium fuel from external sources during operations. In order to achieve these goals, extensive engineering efforts as well as physics studies are required to develop a design that can ensure a high level of plant reliability and availability. In particular, interfaces between systems must be addressed at a very early phase of the project, in order to proceed consistently. In this paper we present a preliminary design and integration study, based on physics assessments for the EU DEMO1 Baseline 2015 with an aspect ratio of 3.1 and 18 toroidal field coils, for the DEMO port plugs. These aim to host systems like electron cyclotron heating launchers currently developed within the Work Package Heating and Current Drive that need an external radial access to the plasma and through in-vessel systems like the breeder blanket. A similar approach shown here could be in principle followed by other systems, e.g. other heating and current drive systems or diagnostics. The work addresses the interfaces between the port plug and the blanket considering the helium-cooled pebble bed and the water cooled lithium lead which are two of four breeding blanket concepts under investigation in Europe within the Power Plant Physics and Technology Programme: the required openings will be evaluated in terms of their impact onto the

  19. Engineering issues on the diagnostic port integration in ITER upper port 18

    Energy Technology Data Exchange (ETDEWEB)

    Pak, Sunil, E-mail: paksunil@nfri.re.kr [National Fusion Research Institute, Gwahak-ro, Yuseong-gu, Daejeon (Korea, Republic of); Bertalot, Luciano [ITER Organization, Route de Vinon sur Verdon, 13115 St Paul-lez-Durance (France); Cheon, Mun Seong [National Fusion Research Institute, Gwahak-ro, Yuseong-gu, Daejeon (Korea, Republic of); Giacomin, Thibaud [ITER Organization, Route de Vinon sur Verdon, 13115 St Paul-lez-Durance (France); Heemskerk, Cock J.M.; Koning, Jarich F. [Heemskerk Innovative Technology, Merelhof 2, 2172 HZ Sassenheim (Netherlands); Lee, Hyeon Gon [National Fusion Research Institute, Gwahak-ro, Yuseong-gu, Daejeon (Korea, Republic of); Nemtcev, Grigorii [Institution “PROJECT CENTER ITER”, Akademika Kurchatova sq., Moscow (Russian Federation); Ronden, Dennis M.S. [FOM Institute DIFFER, P.O. Box 1207, 3430 BE Nieuwegein (Netherlands); Seon, Chang Rae [National Fusion Research Institute, Gwahak-ro, Yuseong-gu, Daejeon (Korea, Republic of); Udintsev, Victor; Yukhnov, Nikolay [ITER Organization, Route de Vinon sur Verdon, 13115 St Paul-lez-Durance (France); Zvonkov, Alexander [Institution “PROJECT CENTER ITER”, Akademika Kurchatova sq., Moscow (Russian Federation)

    2016-11-01

    Highlights: • Diagnostic port integration in the upper port 18 of ITER is presented in order to house the three diagnostic systems. • Issue on the neutron shielding in the upper port 18 is addressed and the shut-down dose rate in the interspace is summarized. • The maintenance strategy in the upper port 18 is described. - Abstract: The upper port #18 (UP18) in ITER hosts three diagnostic systems: the neutron activation system, the Vacuum Ultra-Violet spectrometer system, and the vertical neutron camera. These diagnostics are integrated into three infrastructures in the port: the upper port plug, interspace support structure and port cell support structure. The port integration in UP18 is at the preliminary design stage and the current design of the infrastructure as well as the diagnostic integration is described here. The engineering issues related to neutron shielding and maintenance are addressed and the design approach is suggested.

  20. Analysis of ITER upper port plug remote handling maintenance scenarios

    International Nuclear Information System (INIS)

    Koning, J.F.; Baar, M.R. de; Elzendoorn, B.S.Q.; Heemskerk, C.J.M.; Ronden, D.M.S.; Schuth, W.J.

    2012-01-01

    Highlights: ► Remote Handling Study Centre: providing RH compatibility analysis. ► Simulation: virtual reality including kinematics and realtime physics simulator. ► Applied on analysis of RH compatibility of Upper Launcher component replacement. ► Resulting in lowered maintenance procedure time and lessons learned. - Abstract: The ITER tokamak has a modular design, with port plugs, blanket modules and divertor cassettes. This set-up allows for maintenance of diagnostics, heating systems and first wall elements. The maintenance can be done in situ, or in the Hot Cell. Safe and effective remote handling (RH) will be ensured by the RH requirements and standards. Compliance is verified through remote handling compatibility assessments at the ITER Design Review milestones. The Remote Handling Study Centre at FOM Institute DIFFER is created to study ITER RH maintenance processes at different levels of complexity, from relatively simple situational awareness checks using snap-shots in the CAD system, time studies using virtual reality (VR) animations, to extensive operational sequence validation with multiple operators in real-time. The multi-operator facility mimics an RH work-cell as presently foreseen in the ITER RH control room. Novel VR technology is used to create a realistic setting in which a team of RH operators can interact with virtual ITER environments. A physics engine is used to emulate real-time contact interaction as to provide realistic haptic feed-back. Complex interactions between the RH operators and the control room system software are tested. RH task performance is quantified and operational resource usage estimated. The article provides a description and lessons learned from a recent study on replacement of the Steering Mirror Assembly on the ECRH (Electron Cyclotron Resonance Heating) Upper Launcher port plug.

  1. Analysis of ITER upper port plug remote handling maintenance scenarios

    Energy Technology Data Exchange (ETDEWEB)

    Koning, J.F., E-mail: j.f.koning@heemskerk-innovative.nl [FOM Institute DIFFER - Dutch Institute for Fundamental Energy Research, Association EURATOM-FOM, Partner in the Trilateral Euregio Cluster and ITER-NL, PO Box 1207, 3430 BE Nieuwegein (Netherlands); Baar, M.R. de; Elzendoorn, B.S.Q. [FOM Institute DIFFER - Dutch Institute for Fundamental Energy Research, Association EURATOM-FOM, Partner in the Trilateral Euregio Cluster and ITER-NL, PO Box 1207, 3430 BE Nieuwegein (Netherlands); Heemskerk, C.J.M. [Heemskerk Innovative Technology, Noordwijk (Netherlands); Ronden, D.M.S.; Schuth, W.J. [FOM Institute DIFFER - Dutch Institute for Fundamental Energy Research, Association EURATOM-FOM, Partner in the Trilateral Euregio Cluster and ITER-NL, PO Box 1207, 3430 BE Nieuwegein (Netherlands)

    2012-08-15

    Highlights: Black-Right-Pointing-Pointer Remote Handling Study Centre: providing RH compatibility analysis. Black-Right-Pointing-Pointer Simulation: virtual reality including kinematics and realtime physics simulator. Black-Right-Pointing-Pointer Applied on analysis of RH compatibility of Upper Launcher component replacement. Black-Right-Pointing-Pointer Resulting in lowered maintenance procedure time and lessons learned. - Abstract: The ITER tokamak has a modular design, with port plugs, blanket modules and divertor cassettes. This set-up allows for maintenance of diagnostics, heating systems and first wall elements. The maintenance can be done in situ, or in the Hot Cell. Safe and effective remote handling (RH) will be ensured by the RH requirements and standards. Compliance is verified through remote handling compatibility assessments at the ITER Design Review milestones. The Remote Handling Study Centre at FOM Institute DIFFER is created to study ITER RH maintenance processes at different levels of complexity, from relatively simple situational awareness checks using snap-shots in the CAD system, time studies using virtual reality (VR) animations, to extensive operational sequence validation with multiple operators in real-time. The multi-operator facility mimics an RH work-cell as presently foreseen in the ITER RH control room. Novel VR technology is used to create a realistic setting in which a team of RH operators can interact with virtual ITER environments. A physics engine is used to emulate real-time contact interaction as to provide realistic haptic feed-back. Complex interactions between the RH operators and the control room system software are tested. RH task performance is quantified and operational resource usage estimated. The article provides a description and lessons learned from a recent study on replacement of the Steering Mirror Assembly on the ECRH (Electron Cyclotron Resonance Heating) Upper Launcher port plug.

  2. Thermo-hydraulic analysis of the generic equatorial port plug design

    International Nuclear Information System (INIS)

    Rodríguez, E.; Guirao, J.; Ordieres, J.; Cortizo, J.L.; Iglesias, S.

    2012-01-01

    Highlights: ► Thermo-hydraulic transient performance evaluation and optimization of the GEPP structure cooling/heating system under neutronic heating and baking conditions. ► The optimization of the GEPP box structure's cooling system includes positioning and minimization of number and size of gun drilled channels, complying with the flow and functional requirements during operating and baking conditions. - Abstract: The port-based ITER diagnostic systems are housed primarily in two locations, the equatorial and upper port plugs. The port plug structure provides confinement function, maintains ultra-high vacuum quality and the first confinement barrier for radioactive materials at the ports. The port plug structure design, from the ITER International Organisation (IO), is cooled and heated by pressurized water which flows through a series of gun-drilled water channels and water pipes. The cooling function is required to remove nuclear heating due to radiation during operation of ITER, while the heating function is intended to heat up uniformly the machine during baking condition. The work presented provides coupled thermo-hydraulic analysis and optimization of a Generic Equatorial Port Plug (GEPP) structure cooling and heating system. The optimization performed includes positioning, minimization of number and size of gun drilled channels, complying with the flow and functional requirements during operating and baking conditions.

  3. Neutronics analysis for integration of ITER diagnostics port EP10

    Energy Technology Data Exchange (ETDEWEB)

    Colling, Bethany, E-mail: bethany.colling@ccfe.ac.uk [Culham Centre for Fusion Energy, Culham Science Centre, Abingdon, Oxon OX14 3DB (United Kingdom); Department of Engineering, Lancaster University, Lancashire LA1 4YR (United Kingdom); Eade, Tim [Culham Centre for Fusion Energy, Culham Science Centre, Abingdon, Oxon OX14 3DB (United Kingdom); Joyce, Malcolm J. [Department of Engineering, Lancaster University, Lancashire LA1 4YR (United Kingdom); Pampin, Raul; Seyvet, Fabien [Fusion for Energy, Josep Pla 2, Torres Diagonal Litoral B3, 08019 Barcelona (Spain); Turner, Andrew [Culham Centre for Fusion Energy, Culham Science Centre, Abingdon, Oxon OX14 3DB (United Kingdom); Udintsev, Victor [ITER Organization, Route de Vinon-sur-Verdon, CS 90 046, 13067 St. Paul Lez Durance Cedex (France)

    2016-11-01

    Shutdown dose rate calculations have been performed on an integrated ITER C-lite neutronics model with equatorial port 10. A ‘fully shielded’ configuration, optimised for a given set of diagnostic designs (i.e. shielding in all available space within the port plug drawers), results in a shutdown dose rate in the port interspace, from the activation of materials comprising equatorial port 10, in excess of 2000 μSv/h. Achieving dose rates of 100 μSv/h or less, as required in areas where hands-on maintenance can be performed, in the port interspace region will be challenging. A combination of methods will need to be implemented, such as reducing mass and/or the use of reduced activation steel in the port interspace, optimisation of the diagnostic designs and shielding of the port interspace floor. Further analysis is required to test these options and the ongoing design optimisation of the EP10 diagnostic systems.

  4. Conceptual design on structure and cooling channel of ITER upper port plug

    International Nuclear Information System (INIS)

    Pak, Sunil; Lee, Hyeon Gon; Jung, Ki Jung; Walker, C.; Kim, Doo Gi; Choi, Kwang Suk; Eo, Sang Gon

    2007-01-01

    This study has performed conceptual design on structure and cooling channel for the upper port plug of the International Thermonuclear Experimental Reactor (ITER), in which electron cyclotron heating (ECH) launcher and various diagnostic modules will be installed with the same structure. There are twelve diagnostic plugs and four ECH plugs at the upper port in ITER Tokamak. The use of the same port plug structure is beneficial for installation of diagnostic modules and ECH launcher from the viewpoint of cost reduction and simple RH maintenance. The diagnostic modules have rectangular cross-section and ECH modules have trapezoidal crosssection with the lower part wider. Here was suggested the bolt-jointed common structure of inverted-U shape beam and bottom plate, where the diagnostic and ECH modules are installed onto the bottom plate and then the assembly is bolted to the inverted-U beam from the bottom. The common structure of Inverted-U type was evaluated by considering several aspects, such as installation, remote handling (RH) maintenance, cooling line connection, manufacturing, and structural stiffness. For the inverted-U port plug structure developed here, this paper proposed a network of water channel for cooling and baking. Pressurized water as working fluid has to be supplied into the whole port plug. It consists of the structure, diagnostic/shielding modules fixed onto the bottom plate, and the blanket shield module (BSM) attached to the front. The internal water ways for these three components were designed in the direction that would not only minimize the RH connections, flow restrictors, and the length of water-vacuum welding, but also make the welding reliable. Independent coolant loops were composed for three parts of the structure, BSM, and diagnostic/shielding modules with bottom plate. These loops, therefore, make it possible to perform the leakage test for each one separately. Finally hydraulic analysis has been performed with ANSYS in order to

  5. Process and overview of diagnostics integration in ITER ports

    International Nuclear Information System (INIS)

    Drevon, J.M.; Walsh, M.; Andrew, P.; Barnsley, R.; Bertalot, L.; Bock, M. de; Bora, D.; Bouhamou, R.; Direz, M.F.; Encheva, A.; Fang, T.; Feder, R.; Giacomin, T.; Hellermann, M. von; Jakhar, S.; Johnson, D.; Kaschuk, Y.; Kusama, Y.; Lee, H.G.; Levesy, B.

    2013-01-01

    Highlights: ► An overview of the Port Integration hardware for tenant system hosting inside ITER diagnostics ports is given. ► The main challenges for diagnostic port integration engineering are presented. ► The actions taken for a common modular approach and a coordinated design are detailed. -- Abstract: ITER will have a set of 45 diagnostics to ensure controlled operation. Many of them are integrated in the ITER ports. This paper addresses the integration process of the diagnostic systems and the approach taken to enable coordinated progress. An overview of the Port Integration hardware introduces the various structures needed for hosting tenant systems inside ITER diagnostics ports. The responsibilities of the different parties involved (ITER Organization and the Domestic Agencies) are outlined. The main challenges for diagnostic port integration engineering are summarized. The plan for a common approach to design and manufacture of the supporting structures, in particular the Port Plug is detailed. A coordinated design including common components and a common approach for neutronic analyses is proposed. One particular port, the equatorial port 11, is used to illustrate the approach

  6. The remote handling compatibility analysis of the ITER generic upper port plug structure

    Energy Technology Data Exchange (ETDEWEB)

    Ronden, D.M.S., E-mail: d.m.s.ronden@differ.nl [FOM Institute DIFFER, P.O. Box 1207, 3430 BE Nieuwegein (Netherlands); Dammann, A. [ITER Organization, Route de Vinon sur Verdon, 13115 Saint Paul-lez-Durance (France); Elzendoorn, B. [FOM Institute DIFFER, P.O. Box 1207, 3430 BE Nieuwegein (Netherlands); Giacomin, T. [ITER Organization, Route de Vinon sur Verdon, 13115 Saint Paul-lez-Durance (France); Heemskerk, C. [Heemskerk Innovative Technology, Merelhof 2, 2172 HZ Sassenheim (Netherlands); Loesser, D. [Princeton Plasma Physics Laboratory, Princeton, NJ 08543-0451 (United States); Maquet, P. [ITER Organization, Route de Vinon sur Verdon, 13115 Saint Paul-lez-Durance (France); Oosterhout, J. van [FOM Institute DIFFER, P.O. Box 1207, 3430 BE Nieuwegein (Netherlands); Pak, S.; Pitcher, C.S.; Portales, M.; Proust, M.; Udintsev, V.S.; Walsh, M.J. [ITER Organization, Route de Vinon sur Verdon, 13115 Saint Paul-lez-Durance (France)

    2014-10-15

    Highlights: • We describe the remote handling compatibility of the ITER generic upper port plug. • Concepts are presented of specific design solutions to improve RH compatibility. • Simulation in VR of the GUPP DSM replacement indicates possible collisions. • Specific tooling concepts are proposed for GUPP handling equipment for the hot cell. - Abstract: The ITER diagnostics generic upper port plug (GUPP) is developed as a standardized design for all diagnostic upper port plugs, in which a variety of payloads can be mounted. Here, the remote handling compatibility analysis (RHCA) of the GUPP design is presented that was performed for the GUPP final design review. The analysis focuses mainly on the insertion and extraction procedure of the diagnostic shield module (DSM), a removable cassette that contains the diagnostic in-vessel components. It is foreseen that the DSM is a replaceable component – the procedure of which is to be performed inside the ITER hot cell facility (HCF), where the GUPP can be oriented in a vertical position. The DSM removal procedure in the HCF consists of removing locking pins, an M30 sized shoulder bolt and two electrical straps through the use of a dexterous manipulator, after which the DSM is lifted out of the GUPP by an overhead crane. For optimum access to its internals, the DSM is mounted in a handling device. The insertion of a new or refurbished DSM follows the reverse procedure. The RHCA shows that the GUPP design requires a moderate amount of changes to become fully compatible with RH maintenance requirements.

  7. The remote handling compatibility analysis of the ITER generic upper port plug structure

    International Nuclear Information System (INIS)

    Ronden, D.M.S.; Dammann, A.; Elzendoorn, B.; Giacomin, T.; Heemskerk, C.; Loesser, D.; Maquet, P.; Oosterhout, J. van; Pak, S.; Pitcher, C.S.; Portales, M.; Proust, M.; Udintsev, V.S.; Walsh, M.J.

    2014-01-01

    Highlights: • We describe the remote handling compatibility of the ITER generic upper port plug. • Concepts are presented of specific design solutions to improve RH compatibility. • Simulation in VR of the GUPP DSM replacement indicates possible collisions. • Specific tooling concepts are proposed for GUPP handling equipment for the hot cell. - Abstract: The ITER diagnostics generic upper port plug (GUPP) is developed as a standardized design for all diagnostic upper port plugs, in which a variety of payloads can be mounted. Here, the remote handling compatibility analysis (RHCA) of the GUPP design is presented that was performed for the GUPP final design review. The analysis focuses mainly on the insertion and extraction procedure of the diagnostic shield module (DSM), a removable cassette that contains the diagnostic in-vessel components. It is foreseen that the DSM is a replaceable component – the procedure of which is to be performed inside the ITER hot cell facility (HCF), where the GUPP can be oriented in a vertical position. The DSM removal procedure in the HCF consists of removing locking pins, an M30 sized shoulder bolt and two electrical straps through the use of a dexterous manipulator, after which the DSM is lifted out of the GUPP by an overhead crane. For optimum access to its internals, the DSM is mounted in a handling device. The insertion of a new or refurbished DSM follows the reverse procedure. The RHCA shows that the GUPP design requires a moderate amount of changes to become fully compatible with RH maintenance requirements

  8. Status of ITER TBM port plug conceptual design and analyses

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Byoung Yoon, E-mail: byoungyoon.kim@iter.org [ITER Organization, Route de Vinon sur Verdon, 13115 Saint Paul Lez Durance (France); Sabourin, Flavien; Merola, Mario; Giancarli, Luciano [ITER Organization, Route de Vinon sur Verdon, 13115 Saint Paul Lez Durance (France); Villari, R. [ENEA Frascati (Italy); Di Maio, P.A. [University of Palermo (Italy); Lucca, F.; Marconi, M. [LTCalcoli, Piazza Prinetti 26/B, 23807 Merate (Italy); Levesy, B. [ITER Organization, Route de Vinon sur Verdon, 13115 Saint Paul Lez Durance (France)

    2014-10-15

    Highlights: •ITER TBM PP conceptual design with two dummy TBMs was summarized. •TBM PP shielding capability was assessed to allow hands-on operation. •TBM PP steady state hydraulic performance was investigated. •EM and structural analysis was performed to evaluate structural margin. -- Abstract: The test blanket module port plug (TBM PP) consists of a TBM frame and two TBM-sets. However, at any time of the ITER operation, a TBM set can be replaced by a dummy TBM. The frame provides a standardized interface with the vacuum vessel (VV)/port structure and provides thermal isolation from the shield blanket. As one of the plasma-facing components, it shall withstand heat loads while at the same time provide adequate neutron shielding for the VV and magnet coils. The frame design shall provide a stable engineering solution to hold TBM-sets and also provide a mean for rapid remote handling replacement and refurbishment. This paper presents main design features of the conceptual design of TBM PP with two dummy TBMs. Also analysis results are summarized to evaluate shielding, hydraulic, and thermal and structural performances of the TBM PP design.

  9. Status of ITER TBM port plug conceptual design and analyses

    International Nuclear Information System (INIS)

    Kim, Byoung Yoon; Sabourin, Flavien; Merola, Mario; Giancarli, Luciano; Villari, R.; Di Maio, P.A.; Lucca, F.; Marconi, M.; Levesy, B.

    2014-01-01

    Highlights: •ITER TBM PP conceptual design with two dummy TBMs was summarized. •TBM PP shielding capability was assessed to allow hands-on operation. •TBM PP steady state hydraulic performance was investigated. •EM and structural analysis was performed to evaluate structural margin. -- Abstract: The test blanket module port plug (TBM PP) consists of a TBM frame and two TBM-sets. However, at any time of the ITER operation, a TBM set can be replaced by a dummy TBM. The frame provides a standardized interface with the vacuum vessel (VV)/port structure and provides thermal isolation from the shield blanket. As one of the plasma-facing components, it shall withstand heat loads while at the same time provide adequate neutron shielding for the VV and magnet coils. The frame design shall provide a stable engineering solution to hold TBM-sets and also provide a mean for rapid remote handling replacement and refurbishment. This paper presents main design features of the conceptual design of TBM PP with two dummy TBMs. Also analysis results are summarized to evaluate shielding, hydraulic, and thermal and structural performances of the TBM PP design

  10. Maintenance implications of critical components in ITER CXRS upper port plug design

    International Nuclear Information System (INIS)

    Koning, Jarich; Jaspers, Roger; Doornink, Jan; Ouwehand, Bernard; Klinkhamer, Friso; Snijders, Bart; Sadakov, Sergey; Heemskerk, Cock

    2009-01-01

    Already in the early phase of a design for ITER, the maintenance aspects should be taken into account, since they might have serious implications. This paper presents the arguments in support of the case for the maintainability of the design, notably if this maintenance is to be performed by advanced remote methods. This structure is compliant to the evolving maintenance strategy of ITER. Initial results of a Failure Mode Effects and Criticality Analysis (FMECA) and a development risk analysis for the ITER upper port plug no. 3, housing the Charge Exchange Recombination Spectroscopy (CXRS) diagnostic, are employed for the definition of the maintenance strategy. The CXRS upper port plug is essentially an optical system which transfers visible light from the plasma into a fiber bundle. The most critical component in this path is the first mirror (M1) whose reflectivity degrades during operation due to deposition and/or erosion dominated effects. Amongst other measures to mitigate these effects, the strategy is to allow for a replacement of this mirror. Therefore it is mounted on a retractable central tube. The main purpose of this tube is to make frequent replacements possible without hindering operation. The maintenance method in terms of time, geometry and spare part policy has a large impact on cost of the system and time usage in the hot cell. Replacement of the tube under vacuum and magnetic field seems infeasible due to the operational risk involved. The preferred solution is to have a spare tube available which is replaced in parallel with other maintenance operations on the vessel, as to avoid any interference in the hot cell with the shutdown scheduling. This avoids having to refurbish a full port plug and also allows for a more frequent replacement of M1, as we can replace the mirror anytime the vacuum vessel is vented, estimated to be once a year.

  11. Electromagnetic analysis of ITER generic equatorial port plug designs during three plasma current disruption cases

    International Nuclear Information System (INIS)

    Guirao, J.; Rodríguez, E.; Ordieres, J.; Cabanas, M.F.; García, C.H. Rojas

    2012-01-01

    Highlights: ► Electromagnetic transient performance evaluation of the GEPP structure. ► Three different plasma current disruption cases: MD UP LIN36, VDE UP LIN36 and VDE DW LIN36 were analyzed. ► Three DSM-First Wall (FW) designs (horizontal and vertical drawers and monoblock) were compared. - Abstract: Electromagnetic phenomena due to plasma current disruptions are the cause for the main mechanical operation loads over the ITER equatorial level port plug structures. This paper presents a detailed finite element simulation and analysis of the transient electromagnetic effects of three different plasma current disruption cases over three designs of diagnostic shielding module (DSM) structure. The DSMs are contained into and supported by the generic equatorial port plug (GEPP) analyzed structure. The three plasma disruption cases studied were: major disruption upwards linear decay in 36 ms (MD UP LIN36), vertical displacements events, upwards and downwards linear decay in 36 ms (VDE UP LIN36 and VDE DW LIN36). A detailed analysis for GEPP structure and three DSM-first wall (FW) designs (horizontal and vertical drawers and monoblock) is also presented in order to extract the Eddy current distribution on these devices and thus the resultant electromagnetic forces and moments acting on them.

  12. Support structure concept for integration of ITER diagnostics in the port cell

    Energy Technology Data Exchange (ETDEWEB)

    Udintsev, V.S., E-mail: victor.udintsev@iter.org [ITER Organization, Route de Vinon sur Verdon, 13115 St. Paul-Lez-Durance (France); Portalès, M.; Giacomin, T.; Darcourt, O.; Direz, M.-F.; Martins, J.P.; Penot, C.; Arumugam, A.P.; Drevon, J.-M.; Friconneau, J.P.; Levesy, B.; Maquet, P.; Patel, K.M.; Pitcher, C.S. [ITER Organization, Route de Vinon sur Verdon, 13115 St. Paul-Lez-Durance (France); Popova, E. [Russian Federation Domestic Agency, Moscow (Russian Federation); Proust, M. [ITER Organization, Route de Vinon sur Verdon, 13115 St. Paul-Lez-Durance (France); Ronden, D.M.S. [DIFFER, Nieuwegein (Netherlands); Walker, C.I.; Walsh, M.J.; Watts, C. [ITER Organization, Route de Vinon sur Verdon, 13115 St. Paul-Lez-Durance (France)

    2013-10-15

    Highlights: ► An interspace support structure to support the diagnostic systems from the back of the upper and equatorial port plugs to the biological shield plug. ► Port cell support structures are foreseen to handle the equipment in the port cell. ► Both ISS and PCSS will be supported by means of RH rail system. ► The structures will be positioned with a certain tolerance. ► The proposed concepts are found to fulfil the needs for support of the diagnostics in ITER. -- Abstract: Development of the diagnostics for ITER tokamak, which is presently under construction by several international partners at Cadarache in France, is a major challenge because of severe environment, strict engineering requirements, and the need for high reliability in the measurements. The diagnostic systems in the upper, equatorial and lower port cells on ITER are designed to be integrated within the interspace and port cell support structures. These structures are interfacing with remote handling rail system for the cask operations, thus facilitating the removal and installation of the diagnostics in the port and hence minimizing time for working close to the tokamak. In this paper, the challenges associated with the integration of the diagnostics in the port interspace and port cell, as well as their solutions will be addressed and presented. The interspace and the port cell support structures, as well as their interfaces with the biological shield, will be discussed.

  13. Applying HAZOP analysis in assessing remote handling compatibility of ITER port plugs

    International Nuclear Information System (INIS)

    Duisings, L.P.M.; Til, S. van; Magielsen, A.J.; Ronden, D.M.S.; Elzendoorn, B.S.Q.; Heemskerk, C.J.M.

    2013-01-01

    Highlights: ► We applied HAZOP analysis to assess the criticality of remote handling maintenance activities on port plugs in the ITER Hot Cell facility. ► We identified several weak points in the general upper port plug maintenance concept. ► We made clear recommendations on redesign in port plug design, operational sequence and Hot Cell equipment. ► The use of a HAZOP approach for the ECH UL port can also be applied to ITER port plugs in general. -- Abstract: This paper describes the application of a Hazard and Operability Analysis (HAZOP) methodology in assessing the criticality of remote handling maintenance activities on port plugs in the ITER Hot Cell facility. As part of the ECHUL consortium, the remote handling team at the DIFFER Institute is developing maintenance tools and procedures for critical components of the ECH Upper launcher (UL). Based on NRG's experience with nuclear risk analysis and Hot Cell procedures, early versions of these tool concepts and maintenance procedures were subjected to a HAZOP analysis. The analysis identified several weak points in the general upper port plug maintenance concept and led to clear recommendations on redesigns in port plug design, the operational sequence and ITER Hot Cell equipment. The paper describes the HAZOP methodology and illustrates its application with specific procedures: the Steering Mirror Assembly (SMA) replacement and the exchange of the Mid Shield Optics (MSO) in the ECH UPL. A selection of recommended changes to the launcher design associated with the accessibility, maintainability and manageability of replaceable components are presented

  14. CAD-Based Shielding Analysis for ITER Port Diagnostics

    Directory of Open Access Journals (Sweden)

    Serikov Arkady

    2017-01-01

    Full Text Available Radiation shielding analysis conducted in support of design development of the contemporary diagnostic systems integrated inside the ITER ports is relied on the use of CAD models. This paper presents the CAD-based MCNP Monte Carlo radiation transport and activation analyses for the Diagnostic Upper and Equatorial Port Plugs (UPP #3 and EPP #8, #17. The creation process of the complicated 3D MCNP models of the diagnostics systems was substantially accelerated by application of the CAD-to-MCNP converter programs MCAM and McCad. High performance computing resources of the Helios supercomputer allowed to speed-up the MCNP parallel transport calculations with the MPI/OpenMP interface. The found shielding solutions could be universal, reducing ports R&D costs. The shield block behind the Tritium and Deposit Monitor (TDM optical box was added to study its influence on Shut-Down Dose Rate (SDDR in Port Interspace (PI of EPP#17. Influence of neutron streaming along the Lost Alpha Monitor (LAM on the neutron energy spectra calculated in the Tangential Neutron Spectrometer (TNS of EPP#8. For the UPP#3 with Charge eXchange Recombination Spectroscopy (CXRS-core, an excessive neutron streaming along the CXRS shutter, which should be prevented in further design iteration.

  15. CAD-Based Shielding Analysis for ITER Port Diagnostics

    Science.gov (United States)

    Serikov, Arkady; Fischer, Ulrich; Anthoine, David; Bertalot, Luciano; De Bock, Maartin; O'Connor, Richard; Juarez, Rafael; Krasilnikov, Vitaly

    2017-09-01

    Radiation shielding analysis conducted in support of design development of the contemporary diagnostic systems integrated inside the ITER ports is relied on the use of CAD models. This paper presents the CAD-based MCNP Monte Carlo radiation transport and activation analyses for the Diagnostic Upper and Equatorial Port Plugs (UPP #3 and EPP #8, #17). The creation process of the complicated 3D MCNP models of the diagnostics systems was substantially accelerated by application of the CAD-to-MCNP converter programs MCAM and McCad. High performance computing resources of the Helios supercomputer allowed to speed-up the MCNP parallel transport calculations with the MPI/OpenMP interface. The found shielding solutions could be universal, reducing ports R&D costs. The shield block behind the Tritium and Deposit Monitor (TDM) optical box was added to study its influence on Shut-Down Dose Rate (SDDR) in Port Interspace (PI) of EPP#17. Influence of neutron streaming along the Lost Alpha Monitor (LAM) on the neutron energy spectra calculated in the Tangential Neutron Spectrometer (TNS) of EPP#8. For the UPP#3 with Charge eXchange Recombination Spectroscopy (CXRS-core), an excessive neutron streaming along the CXRS shutter, which should be prevented in further design iteration.

  16. Numerical simulation of draining and drying procedure for the ITER Generic Equatorial Port Plug cooling system

    International Nuclear Information System (INIS)

    Tanchuk, Victor; Grigoriev, Sergey; Lyublin, Boris; Maquet, Philippe; Senik, Konstantin; Pak, Sunil; Udintsev, Victor

    2016-01-01

    Highlights: • The cooling system of the ITER Generic Equatorial Port Plug (GEPP) is of a complicated combination of horizontal and vertical channels. • The calculation model for the entire GEPP cooling circuit comprising 12 sub-circuits and built up of 2421 finite-volume elements has been developed. • Transient analysis of this model simulating the draining procedure by the KORSAR/B1 code has been performed. • Water in amount of 263 g of initial 531 kg in the GEPP remains in the dead-ends of the DSM and DFW channels in 150 s of draining procedure. • Almost 3 h are required to boil off 263 g of water trapped in the dead-ends. - Abstract: For effective vacuum leak testing all cooling circuits serving the ITER vessel and in-vessel components shall be drained and dried so that after this procedure taking less than 100 h the purge gas passing through a component has water content less than 100 ppm. This process is four-stage, with the first stage using a short blast of compressed nitrogen to blow most of water in the coolant channels out of the circuit. This process is hindered by volumes which trap water due to gravity. To remove the trapped water, it is necessary, first, to heat up the structure by hot and compressed nitrogen, and then water is evaporated by depressurized nitrogen. The cooling system of the ITER Diagnostic Equatorial Port Plugs is of a complicated hydraulic configuration. The system branching might make difficult removal of water from the piping in the scheduled draining mode. The authors have proposed the KORSAR computation code to simulate draining of the GEPP cooling circuit. The numerical simulation performed has made it possible to describe the process dynamics during draining of the entire GEPP cooling circuit and to define the process time, amount and location of residual water and evolution of two-phase flow regime.

  17. Numerical simulation of draining and drying procedure for the ITER Generic Equatorial Port Plug cooling system

    Energy Technology Data Exchange (ETDEWEB)

    Tanchuk, Victor, E-mail: Victor.Tanchuk@sintez.niiefa.spb.su [JSC “D.V. Efremov Institute of Electrophysical Apparatus”, 196641 St. Petersburg (Russian Federation); Grigoriev, Sergey; Lyublin, Boris [JSC “D.V. Efremov Institute of Electrophysical Apparatus”, 196641 St. Petersburg (Russian Federation); Maquet, Philippe [ITER Organization, Route de Vinon sur Verdon, 13115 St Paul-lez-Durance (France); Senik, Konstantin [JSC “D.V. Efremov Institute of Electrophysical Apparatus”, 196641 St. Petersburg (Russian Federation); Pak, Sunil [National Fusion Research Institute, Daejeon (Korea, Republic of); Udintsev, Victor [ITER Organization, Route de Vinon sur Verdon, 13115 St Paul-lez-Durance (France)

    2016-11-01

    Highlights: • The cooling system of the ITER Generic Equatorial Port Plug (GEPP) is of a complicated combination of horizontal and vertical channels. • The calculation model for the entire GEPP cooling circuit comprising 12 sub-circuits and built up of 2421 finite-volume elements has been developed. • Transient analysis of this model simulating the draining procedure by the KORSAR/B1 code has been performed. • Water in amount of 263 g of initial 531 kg in the GEPP remains in the dead-ends of the DSM and DFW channels in 150 s of draining procedure. • Almost 3 h are required to boil off 263 g of water trapped in the dead-ends. - Abstract: For effective vacuum leak testing all cooling circuits serving the ITER vessel and in-vessel components shall be drained and dried so that after this procedure taking less than 100 h the purge gas passing through a component has water content less than 100 ppm. This process is four-stage, with the first stage using a short blast of compressed nitrogen to blow most of water in the coolant channels out of the circuit. This process is hindered by volumes which trap water due to gravity. To remove the trapped water, it is necessary, first, to heat up the structure by hot and compressed nitrogen, and then water is evaporated by depressurized nitrogen. The cooling system of the ITER Diagnostic Equatorial Port Plugs is of a complicated hydraulic configuration. The system branching might make difficult removal of water from the piping in the scheduled draining mode. The authors have proposed the KORSAR computation code to simulate draining of the GEPP cooling circuit. The numerical simulation performed has made it possible to describe the process dynamics during draining of the entire GEPP cooling circuit and to define the process time, amount and location of residual water and evolution of two-phase flow regime.

  18. Applying HAZOP analysis in assessing remote handling compatibility of ITER port plugs

    NARCIS (Netherlands)

    Duisings, L. P. M.; van Til, S.; Magielsen, A. J.; Ronden, D. M. S.; Elzendoorn, B. S. Q.; Heemskerk, C. J. M.

    2013-01-01

    This paper describes the application of a Hazard and Operability Analysis (HAZOP) methodology in assessing the criticality of remote handling maintenance activities on port plugs in the ITER Hot Cell facility. As part of the ECHUL consortium, the remote handling team at the DIFFER Institute is

  19. ITER Upper Port Plug handling cask system assessment and design proposals

    NARCIS (Netherlands)

    Pustjens, J.; Friconneau, J.P.; Heemskerk, C.J.M.; Koning, J.F.; Martins, J.P.; Rosielle, P.C.J.N.; Steinbuch, M.

    2011-01-01

    The current design of the ITER cask for Upper Port Plugs has been evaluated. Careful reduction of the number of mechanical degrees of freedom is an opportunity to relax the tolerances in the design, resulting in cost reduction and reliability increase. A new kinematical design for the tractor module

  20. ITER Upper Port Plug Handling Cask System assessment and design proposals

    NARCIS (Netherlands)

    Pustjens, J.; Friconneau, J.P.; Heemskerk, C.J.M.; Koning, J.F.; Martins, J.P.; Rosielle, P.C.J.N.; Steinbuch, M.

    2010-01-01

    The current design of the ITER Cask for Upper Port Plugs (UPPs) has been evaluated. Careful reduction of the number of mechanical Degrees of Freedom is an opportunity to relax the tolerances in the design, resulting in cost reduction and reliability increase. A new kinematical design for the tractor

  1. Study of ITER equatorial port plug handling system and vacuum sealing interface

    Energy Technology Data Exchange (ETDEWEB)

    Martins, Jean-Pierre [Association Euratom CEA, CEA/DSM/IRFM, Cadarache, F-13108 Saint-Paul-lez-Durance (France)], E-mail: jean-pierre.martins@cea.fr; Doceul, Louis; Marol, Sebastien; Delchie, Elise [Association Euratom CEA, CEA/DSM/IRFM, Cadarache, F-13108 Saint-Paul-lez-Durance (France); Cordier, Jean-Jacques; Levesy, Bruno; Tesini, Alessandro [ITER International Organization, F-13108 Saint-Paul-lez-Durance cedex (France); Ciattaglia, Emanuela [EFDA CSU - Garching, Boltzmannstr. 2, D-85748 Garching (Germany); Tivey, Richard [Max-Planck-Institut fuer Plasmaphysik, Boltzmannstr. 2, 85748 Garching (Germany); Gillier, Rene; Abbes, Christophe [GARLOCK - Sealing Technologies - 90, rue de la roche du Geai, F-42029 St-Etienne cedex 1 (France)

    2009-06-15

    In the field of the ITER port plug engineering and integration task, CEA has contributed to define proposals concerning the port plugs vacuum sealing interface with the vessel flange and the equatorial plug handling. The 2001 baseline vacuum flange sealing consisted of TIG welding of a 316L strip plate on to U shapes. This arrangement presented some issues like welding access, implementation of tools, lip consumption, complex local leak test, continuous leak checking. Therefore, an alternate sealing solution based on the use of metallic gaskets is proposed. The different technical aspects are discussed to explain how this design can simplify the maintenance and deal with safety and vacuum requirements. The design of the mechanical attachment and vacuum sealing of the plug has constantly evolved, but the associated remote handling equipment was not systematically reviewed. An update of the cask and maintenance procedure was studied in order to design it in accordance with the last generic plug flange design. This includes a concept of a gripping system that uses the plug flange bolting area and, to help the remote handling process, a cantilever assisting system is suggested to increase the reliability of the transfer operation between vacuum vessel and cask.

  2. Cask and plug handling system design in port cell

    International Nuclear Information System (INIS)

    Martins, Jean-Pierre; Friconneau, Jean-Pierre; Gabellini, Eros; Keller, Delphine; Levesy, Bruno; Selvi, Anna; Tesini, Alessandro; Utin, Yuri; Wagrez, Julien

    2011-01-01

    The ITER maintenance strategy relies partly on the remote transfer of components from vacuum vessel to hot cells. This function will be fulfilled by transfer cask systems. This paper describes the recent design progresses on interfaces in order to increase components handling feasibility by implementing continuous guiding features that avoid cantilevered loads on the in-cask tractor. Also the design has progressed in order to allow generic docking of the casks. When the cask is connected to the port, it becomes part of the machine first confinement boundary, thus it must provide tightness continuity. This high level safety function was one of the main concerns of a finite element analysis study that has been performed to assess the behavior of the whole system. Numerical analysis methodology and results are explained and shown in order to highlight how it has reinforced the knowledge of the system.

  3. The choice of dynamic amplification factors for the ITER generic port plugs during disruptions

    International Nuclear Information System (INIS)

    Vacas, Christian; Rodriguez, Eduardo; Guirao, Julio; Iglesias, Silvia; Udintsev, Victor; Pak, Sunil; Maquet, Philippe; Roces, Jorge; Casal, Natalia

    2015-01-01

    Highlights: • Dynamic amplification factor is largely influenced by the DFWs geometry and for the type of bond between DFW and DSM. • DAF were calculated by analyzing the deformed shape and not just looking at the absolute values of displacements. • Detailed transient time history non-linear analysis of an MDUP II electro magnetic event has been carried out. • Cuasi-constant damping ratio of 3% has been considered using a generalized proportional damping model. - Abstract: The purpose of this paper is present an overview of the methodology followed to calculate the dynamic amplification factors applied to the electromagnetic loads acting in the ITER generic port plugs. The methodology used for combining an EM transient event with another kind of load is based in the treated of this dynamic EM event as a static load. As first stage a transient dynamic analysis was performed, at the most demanded electromagnetic event [2], to determine the dynamic response of the port plugs. In the same way, have been solved all the time steps of the dynamic event as static loads, it means that the inertial effect has been neglected. The response of each time-step at the dynamic solution has been compared with the same time-step solved as a static load. For this purpose some control points were positioned along the structure at the most representative locations. The key of these calculations is the understanding of the deformed modes affecting the port plug in order to obtain a reasonable dynamic amplification factors that permit the characterization of these loads in a realistic way and does not derive in a too conservative approach. Additionally, the fundamental frequencies and vibration modes of the generic port plug, requested for the characterization of the damping effects at the structure, were calculated in a complementary modal analysis performed for this aim.

  4. Measuring robustness of port plug maintenance schedules in fusion remote handling

    Energy Technology Data Exchange (ETDEWEB)

    Schoen, P.W., E-mail: p.w.schoen@heemskerk-innovative.nl [Heemskerk Innovative Technology, Sassenheim (Netherlands); Thomas, J. [CCFE EURATOM/CCFE Fusion Association, Culham Science Centre, Abingdon OX14 3DB (United Kingdom); Boessenkool, H. [FOM Institute DIFFER, Association EURATOM-FOM, Partner in the Trilateral Euregio Cluster, PO Box 1207, 3430 BE Nieuwegein (Netherlands); Heemskerk, C.J.M. [Heemskerk Innovative Technology, Sassenheim (Netherlands)

    2015-12-15

    Unexpected events during maintenance operations of a fusion plant like JET or ITER may require rescheduling, suspending the execution of the current procedure to pick it up later. In this paper, we look at how the introduction of slack influences the port plug maintenance schedule robustness. We introduce a metrics to measure the robustness. Simulating disruptions we evaluate the effect on a schedule. Finally, we show how the robustness is affected when introducing different amounts of slack.

  5. Measuring robustness of port plug maintenance schedules in fusion remote handling

    International Nuclear Information System (INIS)

    Schoen, P.W.; Thomas, J.; Boessenkool, H.; Heemskerk, C.J.M.

    2015-01-01

    Unexpected events during maintenance operations of a fusion plant like JET or ITER may require rescheduling, suspending the execution of the current procedure to pick it up later. In this paper, we look at how the introduction of slack influences the port plug maintenance schedule robustness. We introduce a metrics to measure the robustness. Simulating disruptions we evaluate the effect on a schedule. Finally, we show how the robustness is affected when introducing different amounts of slack.

  6. Shutdown dose rate contribution from diagnostics in ITER upper port 18

    Energy Technology Data Exchange (ETDEWEB)

    Cheon, M.S., E-mail: munseong@nfri.re.kr [National Fusion Research Institute, Daejeon (Korea, Republic of); Pak, S.; An, Y.H.; Seon, C.R.; Lee, H.G. [National Fusion Research Institute, Daejeon (Korea, Republic of); Bertalot, L.; Krasilnikov, V. [ITER Organization, St Paul-lez-Durance (France); Zvonkov, A. [Agency ITER-RF, Moscow (Russian Federation)

    2016-11-01

    Highlights: • The Shutdown Dose Rate in the interspace of ITER upper port 18 was evaluated. • VUV spectrometer is the dominant contributor to the average SDR. • The existence and size of the blanket cooling pipes impacts significantly on SDR. - Abstract: D-T operation of ITER plasma will produce high-energy fusion neutrons those can activate materials around the place where human-access is necessary. The interspace of the diagnostic port is one of the area where human-access is necessary for the maintenance of diagnostic systems installed at the port, so it is important to evaluate a dose rate of the interspace area in order to comply with ALARA principle. The shutdown dose rate (SDR) in the interspace of ITER upper port 18 was evaluated by the Direct 1-Step (D1S) method using MCNP5 code. This port contains three diagnostics: Vacuum Ultra-Violet (VUV) Spectrometer, Neutron Activation System (NAS), and Upper Vertical Neutron Camera (UVNC). The contribution of each diagnostic in the port was evaluated by running separate upper port MCNP models those contain individual diagnostic only, and the total dose rate contribution was evaluated with the model which was fully integrated with all the diagnostics. The effect of the opening around the upper port plug and of the other ports was also investigated. The purpose of this assessment is to provide the shielding design basis for the preliminary design of the diagnostic integration in the port. The method and result of the calculation will be presented in this paper.

  7. Analysis of welding distortion due to narrow-gap welding of upper port plug

    International Nuclear Information System (INIS)

    Biswas, Pankaj; Mandal, N.R.; Vasu, Parameswaran; Padasalag, Shrishail B.

    2010-01-01

    Narrow-gap welding is a low distortion welding process. This process allows very thick plates to be joined using fewer weld passes as compared to conventional V-groove or double V-groove welding. In case of narrow-gap arc welding as the heat input and weld volume is low, it reduces thermal stress leading to reduction of both residual stress and distortion. In this present study the effect of narrow-gap welding was studied on fabrication of a scaled down port plug in the form of a trapezoidal box made of 10 mm thick mild steel (MS) plates using gas tungsten arc welding (GTAW). Inherent strain method was used for numerical prediction of resulting distortions. The numerical results compared well with that of the experimentally measured distortion. The validated numerical scheme was used for prediction of weld induced distortion due to narrow-gap welding of full scale upper port plug made of 60 mm thick SS316LN material as is proposed for use in ITER project. It was observed that it is feasible to fabricate the said port plug keeping the distortions minimum within about 7 mm using GTAW for root pass welding followed by SMAW for filler runs.

  8. Study on the key technologies of the Transfer Equipment Cask for Tokamak Equator Port Plug

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Buyun, E-mail: ayun@iim.ac.cn [Department of Automation, University of Science and Technology of China, Hefei, Anhui 230027 (China); Robot Sensors and Human-Machine Interaction Laboratory, Institute of Intelligent Machines, Chinese Academy of Sciences, Hefei, Anhui 230031 (China); Gao, Lifu [Department of Automation, University of Science and Technology of China, Hefei, Anhui 230027 (China); Robot Sensors and Human-Machine Interaction Laboratory, Institute of Intelligent Machines, Chinese Academy of Sciences, Hefei, Anhui 230031 (China); Cao, Huibin; Sun, Jian [Robot Sensors and Human-Machine Interaction Laboratory, Institute of Intelligent Machines, Chinese Academy of Sciences, Hefei, Anhui 230031 (China); Sun, Yuxiang; Song, Quanjun; Ma, Chengxue; Chang, Li; Shuang, Feng [Department of Automation, University of Science and Technology of China, Hefei, Anhui 230027 (China); Robot Sensors and Human-Machine Interaction Laboratory, Institute of Intelligent Machines, Chinese Academy of Sciences, Hefei, Anhui 230031 (China)

    2014-12-15

    Highlights: • Design on Intelligent Air Transfer System (IATS) for Transfer Equipment Cask (TECA). • A rhombic-like parallel robot for docking with minimum misalignment. • Design on electro-hydraulic servo system of the TECA for Tokamak Equator Port Plug (TEPP) manipulation. • A control architecture with several algorithms and information acquired from sensors could be used by the TECA for Remote Handling (RH). - Abstract: The Transfer Equipment Cask (TECA) is a key solution for Remote Handling (RH) in Tokamak Equator Port Plug (TEPP) operations. From the perspectives of both engineering and technical designs of effective experiments on the TEPP, key technologies on these topics covering the TECA are required. According to conditions in ITER (International Thermonuclear Experimental Reactor) and features of the TEPP, this paper introduces the design of an Intelligent Air Transfer System (IATS) with an adaptive attitude and high precision positioning that transports a cask system of more than 30 tons from the Tokamak Building (TB) to the Hot Cell Building (HCB). Additionally, different actuators are discussed, and the hydraulic power drive is eventually selected and designed. A rhombic-like parallel robot is capable of being used for docking with minimum misalignment. Practical mechanisms of the cask system are presented for hostile environments. A control architecture with several algorithms and information acquired from sensors could be used by the TECA. These designs yield realistic and extended applications for the RH of ITER.

  9. Design and integration of lower ports for ITER diagnostic systems

    Energy Technology Data Exchange (ETDEWEB)

    Casal, Natalia, E-mail: Natalia.casal@iter.org [ITER Organization, Route de Vinon-sur-Verdon – CS 90 046 – 13067 St Paul Lez Durance Cedex (France); Bertalot, Luciano; Cheng, Hao; Drevon, Jean Marc; Duckworth, Philip; Giacomin, Thibaud; Guirao, Julio; Iglesias, Silvia [ITER Organization, Route de Vinon-sur-Verdon – CS 90 046 – 13067 St Paul Lez Durance Cedex (France); Kochergin, Mikhail [IOFFE Institute, Saint Petersburg (Russian Federation); Martin, Alex [ITER Organization, Route de Vinon-sur-Verdon – CS 90 046 – 13067 St Paul Lez Durance Cedex (France); McCarron, Eddie [Oxford Technologies Ltd., Abingdon (United Kingdom); Mokeev, Alexander [Russian Federation Domestic Agency, Moscow (Russian Federation); Mota, Fernando [CIEMAT, Madrid (Spain); Penot, Christophe; Portales, Mickael [ITER Organization, Route de Vinon-sur-Verdon – CS 90 046 – 13067 St Paul Lez Durance Cedex (France); Kitazawa, Sin-iti [Japanese Domestic Agency, Naka (Japan); Sky, Jack [Oxford Technologies Ltd., Abingdon (United Kingdom); Suarez, Alejandro; Udintsev, Victor; Utin, Yuri [ITER Organization, Route de Vinon-sur-Verdon – CS 90 046 – 13067 St Paul Lez Durance Cedex (France); and others

    2015-10-15

    Highlights: • Lower port structures are in its conceptual design phase. • Electromagnetic and seismic loads, will dominate all other mechanical loads. • Design allows diagnostics support, neutron shielding while and signals transmission. • Installation and maintenance operations are fully remote handling compatible. - Abstract: All around the ITER vacuum vessel, forty-four ports will provide access to the vacuum vessel for remote handling operations, diagnostic systems, heating, and vacuum systems: 18 upper ports, 17 equatorial ports, and 9 lower ports. Among the lower ports, three of them will be used for the remote handling installation of the ITER divertor. Once the divertor is in place, these ports will host various diagnostic systems mounted in the so-called diagnostic racks. The diagnostic racks must allow the support and cooling of the diagnostics, extraction of the required diagnostic signals, and providing access and maintainability while minimizing the leakage of radiation toward the back of the port where the humans are allowed to enter. A fully integrated inner rack, carrying the near plasma diagnostic components, will be an stainless steel structure, 4.2 m long, with a maximum weight of 10 t. This structure brings water for cooling and baking at maximum temperature of 240 °C and provides connection with gas, vacuum and electric services. Additional racks (placed away from plasma and not requiring cooling) may be required for the support of some particular diagnostic components. The diagnostics racks and its associated ex vessel structures, which are in its conceptual design phase, are being designed to survive the lifetime of ITER of 20 years. This paper presents the current state of development including interfaces, diagnostic integration, operation and maintenance, shielding requirements, remote handling, loads cases and discussion of the main challenges coming from the severe environment and engineering requirements.

  10. ITER Equatorial Port plug engineering: Design and remote handling activities supported by Virtual Reality tools

    International Nuclear Information System (INIS)

    Keller, Delphine; Dechelle, Christian; Doceul, Louis; Madeleine, Sylvain; Martins, Jean Pierre; Measson, Yvan; Patterlini, Jean Claude; Wagrez, Julien

    2011-01-01

    In the context of ITER, CEA/IRFM has participated to the design and integration of several components in the Equatorial Port plug region. Particularly, in the framework of the grant F4E-2008-GRT-09-PNS-TBM, CEA/IRFM has contributed to the test blanket module system (TBS) design and robot access feasibility study in the Port Cell. Simulations of the maintenance procedure were studied and fully integrated to the design process, enabling to provide space reservation for human and robotic access. For this mean, CEA/IRFM has used a CEA LIST Virtual Reality simulation software directly integrated to the Solidworks CAD software. The feasibility to connect/dis-connect the pipes in front of the Bioshield by a set of potential standard industrial arms was demonstrated. Aiming to give more realism to maintenance scenario and CAD models, CEA IRFM has decided to build a Virtual Reality platform in the institute, integrated to the design office. With the expertise of CEA LIST, this platform aims to provide the nearest possible links between design and remote handling needs. This paper presents the outcome of the robot access study and discusses about the Virtual Reality tools that are being developed for these applications.

  11. ITER Equatorial Port plug engineering: Design and remote handling activities supported by Virtual Reality tools

    Energy Technology Data Exchange (ETDEWEB)

    Keller, Delphine, E-mail: delphine.keller@cea.fr [CEA, IRFM, F-13108 Saint-Paul-Lez-Durance (France); Dechelle, Christian; Doceul, Louis; Madeleine, Sylvain; Martins, Jean Pierre [CEA, IRFM, F-13108 Saint-Paul-Lez-Durance (France); Measson, Yvan [CEA, LIST, Interactive Robotics Unit, 18 route du Panorama, BP6, F-92265 Fontenay Aux Roses (France); Patterlini, Jean Claude; Wagrez, Julien [CEA, IRFM, F-13108 Saint-Paul-Lez-Durance (France)

    2011-10-15

    In the context of ITER, CEA/IRFM has participated to the design and integration of several components in the Equatorial Port plug region. Particularly, in the framework of the grant F4E-2008-GRT-09-PNS-TBM, CEA/IRFM has contributed to the test blanket module system (TBS) design and robot access feasibility study in the Port Cell. Simulations of the maintenance procedure were studied and fully integrated to the design process, enabling to provide space reservation for human and robotic access. For this mean, CEA/IRFM has used a CEA LIST Virtual Reality simulation software directly integrated to the Solidworks CAD software. The feasibility to connect/dis-connect the pipes in front of the Bioshield by a set of potential standard industrial arms was demonstrated. Aiming to give more realism to maintenance scenario and CAD models, CEA IRFM has decided to build a Virtual Reality platform in the institute, integrated to the design office. With the expertise of CEA LIST, this platform aims to provide the nearest possible links between design and remote handling needs. This paper presents the outcome of the robot access study and discusses about the Virtual Reality tools that are being developed for these applications.

  12. Welding feasibility study of U-shape lips at ITER Port-Plug with new laser beam sources

    Energy Technology Data Exchange (ETDEWEB)

    Behr, W., E-mail: w.behr@fz-juelich.de; Faidel, D.; Fischer, K.; Pap, M.; Offermanns, G.

    2013-10-15

    A “Cut and weld feasibility study of U shape lips” shown on June 2007 was initial of the following investigations. A new solution for Port Plug sealing at ITER was demanded and the experience in laser beam welding of the ZAT (Central Institute of Technology) in Jülich (Research Centre Jülich) offered an alternative solution. Up to now mechanically fixed sealing or sealing by TIG welding is used with typical benefits and problems, as heat input, shrinkage or limited room for tools. New disc-laser application for tight welding (leakage rate < 10{sup −9} mbar l/s) of the sealing lips is presented in the following. Both in the metallographic investigation and by means of leakage rate investigation the suitability of the selected procedure as seal alternative at the ITER Port Plug could be pointed out. The distance between two connections can be reduced to approx. 5 mm. The presented milling process for weld seam removal offers an option additionally to laser beam cutting. Final tests with a new disc-laser source offered additional benefits concerning seam quality, process stability and seam geometry. The distance between two connections will be reduced to less than 3 mm in next investigations. Construction unit near investigations and a demo part in original size underline finally the industrial suitability of the laser-welding-process for Port-Plug sealing at ITER.

  13. ITER Port Plug Engineering Trainee Program: Design, manufacturing and integration of structural components (analysis of the attachment)

    International Nuclear Information System (INIS)

    Zeile, Christian; Neuberger, Heiko; Dolensky, Bernhard

    2011-01-01

    The structural connection of helium cooled plasma facing components in ITER to the water cooled structural port plug shield requires an attachment system, which is able to cope with two main contradicting requirements: The attachment system has to be rigid in order to withstand mechanical loads, e.g. due to the deadweight or static and transient electro-magnetic loads. On the other hand, the attachment system has to be flexible in order to compensate the different thermal strains in between the plasma facing test devices (300-550 deg. C) and the port plug structure (∼120 deg. C). The paper presents the latest developments of an attachment system consisting of flexible attachment blocks with lamellae. The optimization steps as well as the connection to the shield are described. The results of the thermo-mechanical analyses under a defined worst-case scenario confirm the feasibility of the lamella design. This work has been performed in the frame of the EFDA goal orientated trainee program on port plug engineering.

  14. The use of the long modular diagnostics shield module to mitigate shutdown dose rates in the ITER diagnostics equatorial ports

    Science.gov (United States)

    Juárez, R.; Guirao, J.; Kolsek, A.; Lopez, A.; Pedroche, G.; Bertalot, L.; Udintsev, V. S.; Walsh, M. J.; Sauvan, P.; Sanz, J.

    2018-05-01

    The ITER equatorial port plugs are submitted to a drained weight limit of 45 T. This limitation can conflict with their radiation shielding demands, although some weight margin is being discussed. The port interspaces are subject to a shutdown dose rate limit of 100 µSv h‑1 after 106 s of cooling time. To meet it, the port plugs must show a neutron flux attenuation comparable to their neighborhood, despite considering penetrations to host systems. Most of this task relies on the drawer shield module (DSM). In this work, two DSM concepts are analyzed with this perspective: the box-based DSM and the modular DSM. Regardless the penetrations, the box-based DSM leads to unsatisfactory port plugs to meet both weight and SDDR requirements. On the contrary, the modular DSM shows a performance which allows for the adoption of such DSM concept, or equivalent, a port may comply with both requirements at the same time, provided the penetrations are well designed.

  15. Mechanism design of the Thomson scattering diagnostic system for the TMX east mirror plug

    International Nuclear Information System (INIS)

    Lang, D.D.; Goodman, R.K.; Jenkins, S.L.; Wilkerson, J.A.; Parkinson, J.L.

    1979-01-01

    This Thomson scattering diagnostic system is used to measure the electron temperature and density of the east mirror plug of the Tandem Mirror Experiment (TMX) at Lawrence Livermore Laboratory. The measurements are made by firing a high-power ruby laser pulse through the plasma where the electrons then re-radiate a small fraction of the light. Because of the velocity of the electrons, the wavelength of the re-radiated light is Doppler shifted. The width of the Doppler-shifted wavelength spectrum is a measure of the temperature of the electrons in the plasma, and the total amount of re-radiated light is proportional to the electron density

  16. Fracture mechanics analysis approach to assess structural integrity of the first confinement boundaries in ITER Generic Upper Port Plug structure

    Energy Technology Data Exchange (ETDEWEB)

    Guirao, Julio, E-mail: julio@natec-ingenieros.com [Numerical Analysis Technologies S.L. (NATEC), Gijon (Spain); Iglesias, Silvia; Vacas, Christian; Udintsev, Victor [CHD, Diagnostic Division, ITER Organization, Route de Vinon-sur-Verdon, CS 90 046, 13067 St. Paul Lez Durance Cedex (France); Pak, Sunil [Diagnostic and Control Team, National Fusion Research Institute, Daejeon (Korea, Republic of); Maquet, Philippe [CHD, Diagnostic Division, ITER Organization, Route de Vinon-sur-Verdon, CS 90 046, 13067 St. Paul Lez Durance Cedex (France); Rodriguez, Eduardo; Roces, Jorge [Department of Construction and Manufacturing Engineering, University of Oviedo, Gijon (Spain)

    2015-10-15

    Highlights: • A parametric submodel of the spot under study is developed. • The associated macro has the capability to successively re-build the submodel implementing the crack with the geometry of the updated crack front as a function of the predicted increments of length in the apexes of the crack from the calculated stress intensity factor at the crack front. • The analysis incorporates the crack behavior model to predict the evolution of the postulated defect under the application of the different transients. • The analysis is based on the Elasto-Plastic Fracture Mechanics (EPFM) theory to account for the ductility of the materials (316LN type stainless steel). - Abstract: This paper demonstrates structural integrity of the first confinement boundary in Generic Upper Port Plug structures against cracking during service. This constitutes part of the justification to demonstrate that the non-aggression to the confinement barrier requirement may be compatible with the absent of a specific in-service inspections (ISI) program in the trapezoidal section. Since the component will be subjected to 100% volumetric inspections it can be assumed that no defects below the threshold of applied Nondestructive Evaluation techniques will be present before its commissioning. Cracks during service would be associated to defects under Code acceptance limit. This limit can be reasonably taken as 2 mm. Using elastic–plastic fracture mechanics an initial defect is postulated at the worst location in terms of probability and impact on the confinement boundary. Its evolution is simulated through finite element analysis and final dimension at the end of service is estimated. Applying the procedures in RCC-MR 2007 (App-16) the stability of the crack is assessed. As relative high safety margin was achieved, a complementary assessment postulating an initial defect of 6 mm was also conducted. New margin calculated provides a more robust design.

  17. Design of the integration interface between the EU HCPB TBM and the ITER TBM port plug including hot cell operations for connection

    International Nuclear Information System (INIS)

    Neuberger, H.; Boccaccini, L.V.; Roccella, R.

    2007-01-01

    In the frame of the activities of the EU Breeder Blanket Programme and of the Test Blanket Working Group, the Helium Cooled Pebble Bed Test Blanket Module- (HCPB-TBM) System is developed. The TBM test schedule foresees four different campaigns for simulation of DEMO relevant conditions, campaign requires a dedicate TBM. Therefore a concept for TBM integration into ITER is designed with attention to simplify the mounting/dismounting operations. This paper presents the status of this concept with regard to the operations in hot cell required to install a new TBM into an equatorial TBM Port Plug (PP). This includes the establishment of the connection for the attachment, supply- and diagnostic lines in the environment of the interface (IF 1) between the TBM rear part and the PP backside shield. The connection of IF 1 has to be designed to cope with a temperature difference between TBM and PP (∝200 K) and the EM-loads during normal operation and disruption scenarios. The reference attachment concept based on shear keys and flexible cartridges is revised to cope with new conditions on the load and at the interface to the PP. According to the latest results of EM analysis, a radial component of the Maxwell forces (due to the ferromagnetic structural material) has been identified as an additional challenging load for the attachment. Furthermore, the replacing operations at IF 1 are influenced by the design of the PP; the recent ITER proposal based on a removable back side shield allows access to the IF 1 from the periphery after the frame of the PP surrounding the TBM is removed. As for the mechanical attachment, the tools and operations for connection of the TBM supply lines (Helium-, Purge- and measurement lines for different purpose depending on the test schedule) are strongly influenced by the restrictions to access IF 1, too. Dismantling of the frame would allow direct access to the interface by e.g. orbital welding tools. The concept for connection of the TBM

  18. On the theoretical–numerical study of the ITER Upper Port Plug structure hydraulic behaviour under steady state and draining and drying transient conditions

    International Nuclear Information System (INIS)

    Di Maio, P.A.; Paradiso, D.; Dell’Orco, G.; Pitcher, C.S.; Kalish, M.

    2011-01-01

    Highlights: ► UPP TS hydraulic behaviour has been investigated under steady state and D and D transient conditions. ► A thermal–hydraulic system code has been adopted and a UPP TS model has been set-up and validated against results of steady state CFD analyses. ► The TS steady state hydraulic characteristic functions have been derived for two coolant flow paths showing that right plate inlet one is the most promising. ► Draining simulations indicate that the 4 MPa injection pressure is high enough to drain almost completely the circuit in a reasonable time (∼6 s). ► Results indicate that right plate inlet flow path allows the TS complete draining, eliminating the need for the drying procedure. - Abstract: The ITER diagnostic Upper Port Plug (UPP) is a water-cooled stainless steel structure aimed to integrate within vacuum vessel the plasma diagnostic systems, shielding them from neutron and photon irradiation. Due to the very intense heat loads expected, a proper cooling circuit has been designed to ensure an adequate UPP cooling with an acceptable thermal rise and an unduly high pumping power and to perform its draining and drying procedure by injection of pressurized nitrogen. A theoretical research activity has been launched at the Department of Nuclear Engineering of the University of Palermo aiming to investigate the hydraulic behaviour of the UPP Trapezoid Section cooling circuit under steady state conditions and during its draining and drying transient procedure. The research activity has been performed following a theoretical–computational approach and adopting the RELAP5 thermal–hydraulic system code. The Trapezoid Section cooling circuit characteristic functions have been derived under steady state conditions at various coolant temperatures for both the coolant flow paths at the present under consideration for this circuit. The distributions of coolant mass flow rates along the channels of the cooling circuit have been calculated too

  19. Plug-and-play paper-based toolkit for rapid prototyping of microfluidics and electronics towards point-of-care diagnostic solutions

    CSIR Research Space (South Africa)

    Smith, S

    2015-11-01

    Full Text Available We present a plug-and-play toolkit for the rapid assembly of paper-based microfluidic and electronic components for quick prototyping of paper-based components towards point-of-care diagnostic solutions. Individual modules, each with a specific...

  20. Shutdown dose rates at ITER equatorial ports considering radiation cross-talk from torus cryopump lower port

    Energy Technology Data Exchange (ETDEWEB)

    Juárez, Rafael, E-mail: rjuarez@ind.uned.es [Departamento de Ingeniería Energética, ETSII-UNED, Calle Juan del Rosal 12, Madrid 28040 (Spain); Pampin, Raul [F4E, Torres Diagonal Litoral B3, Josep Pla 2, Barcelona 08019 (Spain); Levesy, Bruno [ITER Organization, 13115 Route de Vinon sur Verdon, St Paul Lez Durance (France); Moro, Fabio [ENEA, Via Enrico Fermi 45, Frascati, Rome (Italy); Suarez, Alejandro [ITER Organization, 13115 Route de Vinon sur Verdon, St Paul Lez Durance (France); Sanz, Javier [Departamento de Ingeniería Energética, ETSII-UNED, Calle Juan del Rosal 12, Madrid 28040 (Spain)

    2015-11-15

    Shutdown dose rates for planned maintenance purposes is an active research field in ITER. In this work the radiation (neutron and gamma) cross-talk between ports in the most conservative case foreseen in ITER is investigated: the presence of a torus cryopump lower port, mostly empty for pumping efficiency reasons. There will be six of those ports: #4, #6, #10, #12, #16 and #18. The equatorial ports placed above them will receive a significant amount of additional radiation affecting the shutdown dose rates during in situ maintenance activities inside the cryostat, and particularly in the port interspace area. In this study a general situation to all the equatorial ports placed above torus cryopump lower ports is considered: a generic diagnostics equatorial port placed above the torus cryopump lower port (LP#4). In terms of shutdown dose rates at equatorial port interspace after 10{sup 6} s of cooling time, 405 μSv/h has been obtained, of which 160 μSv/h (40%) are exclusively due to radiation cross-talk from a torus cryopump lower port. Equatorial port activation due to only “local neutrons” contributes 166 μSv/h at port interspace, showing that radiation cross-talk from such a lower port is a phenomenon comparable in magnitude to the neutron leakage though the equatorial port plug.

  1. Core barrel plug

    International Nuclear Information System (INIS)

    Tolino, R.W.; Hopkins, R.J.; Congleton, R.L.; Popalis, C.H.

    1986-01-01

    A plug is described for preventing flow through a port in a core barrel of a pressurized water nuclear reactor which consists of: a substantially cylindrical body formed with a cylindrical portion and a flange and defining a tapered leading open end with the other end being closed by an end plug attached to the flange, the body defining a bore therein extending from the open end to the end plug with the bore having a smaller diameter near the open end than near the end plug, the cylindrical portion having a lip near the open end and being formed with longitudinal slots extending from the open end toward the flange and extending entirely through the thickness of the cylindrical portion, the cylindrical portion having a circumferential first groove on the outer surface thereof located near the forwardmost portion of the cylindrical portion but not in the section of the cylindrical portion that has the slots therein, and a plurality of circumferential second grooves on the outer surface thereof located in the section of the cylindrical portion that has the slots therein, the first and second grooves establishing a seal between the cylindrical portion and the inside surface of the port when the cylindrical portion is expanded, and the flange and the end plug having a passageway defined therein for introducing a fluid into the body; a metal ring disposed in each of the second grooves; a mandrel slidably disposed and captured in the body and capable of being moved toward the open end of the body when the fluid is introduced through the passageway, thereby causing the cylindrical portion to be expanded into contact with the inside surface of the port; and a locking mechanism disposed in the end plug for preventing inadvertent movement of the mandrel

  2. Vascular plugs - A key companion to Interventionists - 'Just Plug it'.

    Science.gov (United States)

    Ramakrishnan, Sivasubramanian

    2015-01-01

    Vascular plugs are ideally suited to close extra-cardiac, high flowing vascular communications. The family of vascular plugs has expanded. Vascular plugs in general have a lower profile and the newer variants can be delivered even through a diagnostic catheter. These features make them versatile and easy to use. The Amplatzer vascular plugs are also used for closing intracardiac defects including coronary arterio-venous fistula and paravalvular leakage in an off-label fashion. In this review, the features of currently available vascular plugs are reviewed along with tips and tricks of using them in the cardiac catheterization laboratory. Copyright © 2015. Published by Elsevier B.V.

  3. Multiple-port valve

    International Nuclear Information System (INIS)

    Doody, T.J.

    1978-01-01

    A multiple-port valve assembly is designed to direct flow from a primary conduit into any one of a plurality of secondary conduits as well as to direct a reverse flow. The valve includes two mating hemispherical sockets that rotatably receive a spherical valve plug. The valve plug is attached to the primary conduit and includes diverging passageways from that conduit to a plurality of ports. Each of the ports is alignable with one or more of a plurality of secondary conduits fitting into one of the hemispherical sockets. The other hemispherical socket includes a slot for the primary conduit such that the conduit's motion along that slot with rotation of the spherical plug about various axes will position the valve-plug ports in respect to the secondary conduits

  4. Tube plug

    International Nuclear Information System (INIS)

    Zafred, P. R.

    1985-01-01

    The tube plug comprises a one piece mechanical plug having one open end and one closed end which is capable of being inserted in a heat exchange tube and internally expanded into contact with the inside surface of the heat exchange tube for preventing flow of a coolant through the heat exchange tube. The tube plug also comprises a groove extending around the outside circumference thereof which has an elastomeric material disposed in the groove for enhancing the seal between the tube plug and the tube

  5. Development of ITER diagnostics: Neutronic analysis and radiation hardness

    Energy Technology Data Exchange (ETDEWEB)

    Vukolov, Konstantin, E-mail: vukolov_KY@nrcki.ru; Borisov, Andrey; Deryabina, Natalya; Orlovskiy, Ilya

    2015-10-15

    Highlights: • Problems of ITER diagnostics caused by neutron radiation from hot DT plasma considered. • Careful neutronic analysis is necessary for ITER diagnostics development. • Effective nuclear shielding for ITER diagnostics in the 11th equatorial port plug proposed. • Requirements for study of radiation hardness of diagnostic elements defined. • Results of optical glasses irradiation tests in a fission reactor given. - Abstract: The paper is dedicated to the problems of ITER diagnostics caused by effects of radiation from hot DT plasma. An effective nuclear shielding must be arranged in diagnostic port plugs to meet the nuclear safety requirements and to provide reliable operation of the diagnostics. This task can be solved with the help of neutronic analysis of the diagnostics environment within the port plugs at the design stage. Problems of neutronic calculations are demonstrated for the 11th equatorial port plug. The numerical simulation includes the calculations of neutron fluxes in the port-plug and in the interspace. Options for nuclear shielding, such as tungsten collimator, boron carbide and water moderators, stainless steel and lead screens are considered. Data on neutron fluxes along diagnostic labyrinths allow to define radiation hardness requirements for the diagnostic components and to specify their materials. Options for windows and lenses materials for optical diagnostics are described. The results of irradiation of flint and silica glasses in nuclear reactor have shown that silica KU-1 and KS-4V retain transparency in visible range after neutron fluence of 10{sup 17} cm{sup −2}. Flints required for achromatic objectives have much less radiation hardness about 5 × 10{sup 14} n/cm{sup 2}.

  6. Vacuum vessel port structures for ITER-FEAT

    International Nuclear Information System (INIS)

    Utin, Yu.; Ioki, K.; Komarov, V.; Krylov, V.; Kuzmin, E.; Labusov, I.; Miki, N.; Onozuka, M.; Rozov, V.; Sannazzaro, G.; Tesini, A.; Yamada, M.; Barthel, Th.

    2001-01-01

    The equatorial and the upper port structures are the most loaded among those of the ITER-FEAT vacuum vessel (VV). For all of these ports, the VV closure plate and the in-port components are integrated into the port plug. The plugs/port structures are affected by plasma events and must withstand high mechanical loads. Based on typical port plugs, this paper presents the conceptual design of the port structures (with emphasis on the supporting system), and the results of analyses performed

  7. Vacuum vessel port structures for ITER-FEAT

    Energy Technology Data Exchange (ETDEWEB)

    Utin, Yu.; Ioki, K.; Komarov, V.; Krylov, V.; Kuzmin, E.; Labusov, I.; Miki, N.; Onozuka, M.; Rozov, V.; Sannazzaro, G.; Tesini, A.; Yamada, M.; Barthel, Th

    2001-11-01

    The equatorial and the upper port structures are the most loaded among those of the ITER-FEAT vacuum vessel (VV). For all of these ports, the VV closure plate and the in-port components are integrated into the port plug. The plugs/port structures are affected by plasma events and must withstand high mechanical loads. Based on typical port plugs, this paper presents the conceptual design of the port structures (with emphasis on the supporting system), and the results of analyses performed.

  8. Rotary plug

    International Nuclear Information System (INIS)

    Yamada, Keiji.

    1979-01-01

    Purpose: In a rotating plug of a reactor using a liquid metal as a coolant as in the case of a fbr type reactor, to prevent the ingress of Na vapor into the sliding surface of the rotating plug. Constitution: A rotating plug comprising a large disc covering the upper part of a reactor pressure vessel containing therein a liquid metal and forming surfaces for mounting a shielding device and various other devices, and at least one or more of small discs provided rotatably and eccentrically within said large disc, which is characterized in that an elastic member consisting of bellows and a sealing is interposed between said large disc and said small discs. (Nakamura, S.)

  9. Plugging solution

    Energy Technology Data Exchange (ETDEWEB)

    Sharipov, A U; Yangirov, I Z

    1982-01-01

    A clay-powder, cement, and water-base plugging solution is proposed having reduced solution viscosity characteristics while maintaining tensile strength in cement stone. This solution utilizes silver graphite and its ingredients, by mass weight, are as follows: cement 51.2-54.3%; claypowder 6.06-9.1%; silver graphite 0.24-0.33%; with water making up the remainder.

  10. Plug Power

    Energy Technology Data Exchange (ETDEWEB)

    Marsh, A. [Plug Power Inc., New York, NY (United States)

    2009-07-01

    This presentation described Plug Power's GenDrive hydrogen fuel cell unit that supplies the power needs for folk lift trucks used in high-throughput distribution and high-volume manufacturing operations. The system offers an alternative to lead acid batteries, providing maximum performance at all times during use. The system is particularly useful in the material handling industry, where the revenue generated is based on operator uptime and lift truck productivity. The use of the system allows customers to reduce operational costs and expand valuable floor space by eliminating batteries and associated recharging infrastructure. Fuel cell units also reduce the wear on truck motors. Truck operators can easily and safely refuel at hydrogen fueling stations in 1-5 minutes. GenDrive works with all major OEM lift trucks, making the transition seamless. Commercial customers are investing in this solution to improve their current operations. In 2008, Plug Power sold to Wal-Mart, Bridgestone Firestone and Nestle. Most notably, Central Grocers purchased 220 fuel cell units for a new greenfield distribution center. Plug Power currently has more than 380 systems in operation.

  11. Shielding plugs

    International Nuclear Information System (INIS)

    Makishima, Kenji.

    1986-01-01

    Purpose: In shielding plugs of an LMFBR type reactor, to restrain natural convection of heat in an annular space between a thermal shield layer and a shield shell, to prevent the lowering of heat-insulation performance, and to alleviate a thermal stress in a reactor container and the shield shell. Constitution: A ring-like leaf spring split in the direction of height is disposed in an annular space between a thermal shield layer and a shield shell. In consequence, the space is partitioned in the direction of height and, therefore, if axial temperature conditions and space width are the same and the space is low, the natural convection is hard to occur. Thus the rise of upper surface temperature of the shielding plugs can prevent the lowering of the heat insulation performance which will result in the increment of shielding plug cooling capacity, thereby improving reliability. In the meantime, since there is mounted an earthquake-resisting support, the thermal shield layer will move for a slight gap in case of an earthquake, being supported by the earthquake-resisting support, and the movement of the thermal shield layer is restricted, thereby maintaining integrity without increasing the stroke of the ring-like spring. (Kawakami, Y.)

  12. Infrared tomography for diagnostic imaging of port wine stain blood vessels

    Energy Technology Data Exchange (ETDEWEB)

    Goodman, D. [Lawrence Livermore National Lab., CA (United States)

    1994-11-15

    The objective of this work is the development of Infrared Tomography (IRT) for detecting and characterizing subsurface chromophores in human skin. Characterization of cutaneous chromophores is crucial for advances in the laser treatment of pigmented lesions (e.g., port wine stain birthmarks and tatoos). Infrared tomography (IRT) uses a fast infrared focal plane array (IR-FPA) to detect temperature rises in a substrate induced by pulsed radiation. A pulsed laser is used to produce transient heating of an object. The temperature rise, due to the optical absorption of the pulsed laser light, creates an increase in infrared emission which is measured by the IR-FPA. Although the application of IRT to image subsurface cracks due to metal fatigue is a topic of great interest in the aircraft industry, the application to image subsurface chromophores in biological materials is novel. We present an image recovery method based on a constrained conjugate gradient algorithm that has obtained the first ever high quality images of port wine blood vessels.

  13. Imaging diagnostics of ethanol port fuel injection sprays for automobile engine applications

    International Nuclear Information System (INIS)

    Padala, Srinivas; Le, Minh Khoi; Kook, Sanghoon; Hawkes, Evatt R.

    2013-01-01

    This paper presents characteristics of ethanol sprays at port fuel injection (PFI) conditions with variations in injection and ambient parameters. Details of temporal and spatial development of ethanol PFI sprays are studied using Mie-scattering and high-speed shadowgraph imaging techniques. Momentum flux-based injection rate measurement is also performed. The influences of fuel flow-rate, injection duration, and ambient air cross-flow are of particular interest in an effort to understand ethanol PFI spray characteristics that are relevant to automobile engines. For comparison purposes, the results from gasoline fuel are also presented. Ethanol flow-rate effects are studied using two injectors with different nozzle-hole sizes at a fixed injection pressure. From the experiments, it was found that the actual injection duration was longer for the higher flow-rate injector although an electronic pulse width was fixed. This was due to an extended delay in the injector needle closing as the flow resistance against the needle was increased for the high flow-rate injector. For liquid droplets, the larger hole size of the higher flow-rate injector caused a higher mean droplet diameter and higher number of droplets. Injection duration was also varied to study transient spray behaviour: short-injection sprays with the end-of-injection transient dominating the overall spray development were compared to long, steady-injection sprays. From Mie-scattering images, the number of droplets and mean droplet diameter were found to be less for the short injection sprays. Detailed analysis using an axial profile of the number of droplets and mean droplet diameter suggested that the observed trends were a result of increased evaporation rate near the nozzle after the end of injection. This was consistent with shadowgraph images showing no liquid regions but only the vapour-phase fuel near the nozzle. Under the influence of ambient air cross-flow, both mean droplet diameter and number of

  14. Starting manufacturing phase of ITER upper ports

    Energy Technology Data Exchange (ETDEWEB)

    Utin, Yuri, E-mail: yuri.utin@iter.org [ITER Organization, Route de Vinon-sur-Verdon, CS 90 046, 13067 St. Paul Lez Durance Cedex (France); Alekseev, Alexander; Sborchia, Carlo; Choi, Changho; Albin, Vincent; Barabash, Vladimir; Davis, James [ITER Organization, Route de Vinon-sur-Verdon, CS 90 046, 13067 St. Paul Lez Durance Cedex (France); Fabritsiev, Sergey [NTC Sintez, Efremov Inst., 189631 Metallostroy, St. Petersburg (Russian Federation); Giraud, Benoit; Guirao, Julio [ITER Organization, Route de Vinon-sur-Verdon, CS 90 046, 13067 St. Paul Lez Durance Cedex (France); Koenig, Werner [MAN Diesel & Turbo SE, Werftstrasse 17, Deggendorf (Germany); Kedrov, Igor; Kuzmin, Evgeny [NTC Sintez, Efremov Inst., 189631 Metallostroy, St. Petersburg (Russian Federation); Levesy, Bruno; Martinez, Jean-Marc [ITER Organization, Route de Vinon-sur-Verdon, CS 90 046, 13067 St. Paul Lez Durance Cedex (France); Prebeck, Markus [MAN Diesel & Turbo SE, Werftstrasse 17, Deggendorf (Germany); Privalova, Elena [NTC Sintez, Efremov Inst., 189631 Metallostroy, St. Petersburg (Russian Federation); Ranzinger, Franz [MAN Diesel & Turbo SE, Werftstrasse 17, Deggendorf (Germany); Savrukhin, Petr [Russian Federation ITER Domestic Agency, Kurchatov sq.1, 123182 Moscow (Russian Federation); Schiller, Thomas [MAN Diesel & Turbo SE, Werftstrasse 17, Deggendorf (Germany); and others

    2015-10-15

    Highlights: • The port plugs are attached to the ports with high-strength fasteners. • Tightening of the fasteners via inductive heating was tested. • A concept for the port/plug sealing with metal-type gaskets has progressed. • Manufacturing design of the Upper Ports is in progress. • A full-scale mock-up of double-wall part of the port stub extension is in manufacturing process – acceptable final tolerances are expected. - Abstract: The ITER Vacuum Vessel (VV) features upper, equatorial and lower ports. The upper and regular equatorial ports are occupied by the port plugs. Although the port design has been overall completed in the past, the design of some remaining interfaces was still in progress: in particular, the Sealing Flange package, which includes the high-vacuum seals and the plug fasteners. As the ITER construction phase has started, the procurement of the VV ports has been launched. The VV upper ports will be procured by the Russian Federation Domestic Agency. The main suppliers were selected and the manufacturing design of the first parts is in full progress now. Since the VV is classified at nuclear level N2, the design and manufacture of its components are to be compliant with the French RCC-MR code and regulations for nuclear pressure equipment in France. These regulations make a strong impact to the port design and manufacturing process.

  15. Starting manufacturing phase of ITER upper ports

    International Nuclear Information System (INIS)

    Utin, Yuri; Alekseev, Alexander; Sborchia, Carlo; Choi, Changho; Albin, Vincent; Barabash, Vladimir; Davis, James; Fabritsiev, Sergey; Giraud, Benoit; Guirao, Julio; Koenig, Werner; Kedrov, Igor; Kuzmin, Evgeny; Levesy, Bruno; Martinez, Jean-Marc; Prebeck, Markus; Privalova, Elena; Ranzinger, Franz; Savrukhin, Petr; Schiller, Thomas

    2015-01-01

    Highlights: • The port plugs are attached to the ports with high-strength fasteners. • Tightening of the fasteners via inductive heating was tested. • A concept for the port/plug sealing with metal-type gaskets has progressed. • Manufacturing design of the Upper Ports is in progress. • A full-scale mock-up of double-wall part of the port stub extension is in manufacturing process – acceptable final tolerances are expected. - Abstract: The ITER Vacuum Vessel (VV) features upper, equatorial and lower ports. The upper and regular equatorial ports are occupied by the port plugs. Although the port design has been overall completed in the past, the design of some remaining interfaces was still in progress: in particular, the Sealing Flange package, which includes the high-vacuum seals and the plug fasteners. As the ITER construction phase has started, the procurement of the VV ports has been launched. The VV upper ports will be procured by the Russian Federation Domestic Agency. The main suppliers were selected and the manufacturing design of the first parts is in full progress now. Since the VV is classified at nuclear level N2, the design and manufacture of its components are to be compliant with the French RCC-MR code and regulations for nuclear pressure equipment in France. These regulations make a strong impact to the port design and manufacturing process.

  16. Impact of the layout of the ITER Radial Neutron Camera in-port system on the measurement of the neutron emissivity profile

    International Nuclear Information System (INIS)

    Marocco, D.; Moro, F.; Esposito, B.; Brolatti, G.; Villari, R.; Salasca, S.; Cantone, B.

    2013-01-01

    Highlights: ► MCNP ITER model ‘Alite-4′ has been updated with the new Port Plug structure (three vertical drawers). ► Two different layouts for the Radial Neutron Camera (RNC) in-vessel system have been considered. ► The impact of both layouts on the RNC diagnostic performance has been assessed. ► The analysis provides useful information for a proper integration of the RNC in the EPP1. -- Abstract: The Radial Neutron Camera (RNC), located in the ITER Equatorial Port Plug 1 (EPP1), is designed to provide the neutron emissivity profile through the measurement of the neutron flux along several collimated channels. The present design of the RNC is based on collimating structures: an ex-port system viewing the plasma core and an in-port system composed by two detector cassettes viewing the upper and lower plasma edges. A design of the EPP1 in which the diagnostics are installed in three completely independent vertical drawers is under study. In this frame, space optimization and integration issues suggest two possible solutions for the layout of the in-port RNC cassettes: the first one in which both cassettes are located in a side drawer; the second one in which the two cassettes lie in the central drawer, on opposite sides of the ex-port RNC cut-out. This paper describes the work performed to assess the impact of the two different in-port system layouts on the capability of the RNC to measure the neutron emissivity profile by means of MCNP and diagnostic performance calculations. The results of the analysis provide guidelines for the integration of the RNC into the EPP1 showing that the proximity of the in-port cassettes to the ex-port cut-out strongly increases the amount of uncollimated and scattered neutrons at the detector positions, thus reducing the diagnostic measurement capability

  17. Shielding plug device

    International Nuclear Information System (INIS)

    Orii, Shoichi; Hasegawa, Satoshi; Makishima, Kenji.

    1976-01-01

    Object: To reduce the size of and extend the life of a revolving bearing and facilitate the laying of driving cables and duct lines, this being accomplished by providing plug raising means of a fast breeder on a stationary plug mounting base so as to prevent the shearing force of sodium from acting upon the revolving bearing. Structure: The shield plug means comprises a stationary plug secured to the open end of the reactor container, a rotary plug rotatable with respect to the stationary plug, an annular base formed on top of the stationary plug so as to cover the rotary plug, a bearing secured to the rotary plug edge lower face and upper and lower locking plates. At the time of the rotation of the rotary plug, the upper locking plate is withdrawn, the stationary plug is raised to release the seal structure, and the lower locking plate is inserted between the bearing and stationary plug. In this way, smooth rotation of the rotary plug can be obtained. (Horiuchi, T.)

  18. ITER diagnostics ex-vessel engineering services

    Energy Technology Data Exchange (ETDEWEB)

    Arumugam, A.P., E-mail: arun.prakash@iter.org; Walker, C.I.; Andrew, P.; Barnsley, R.; Beltran, D.; Bertalot, L.; Dammann, A.; Direz, M.F.; Drevon, J.M.; Encheva, A.; Giacomin, T.; Hourtoule, J.; Kuehn, I.; Lanza, R.; Levesy, B.; Maquet, P.; Patel, K.M.; Patisson, L.; Pitcher, C.S.; Portales, M.; and others

    2013-10-15

    Highlights: • This paper describes about the ITER diagnostics ex-vessel engineering services. • It describes various diagnostics systems, its location and its environment. • Diagnostics interfaces with other services such as the buildings, HVAC, electrical services, cooling water, vacuum, liquid and gas distribution. • All the interfaces with these services are identified and defined. • Buildings services for diagnostics, such as penetrations, local shielding, embedment and temperature control are discussed. -- Abstract: Extensive diagnostics systems will be installed on the ITER machine to provide the measurements necessary to control, evaluate and optimize plasma performance in ITER and to further the understanding of plasma physics. These include measurements of temperature, density, impurity concentration, and particle and energy confinement times. ITER diagnostic systems extend from the center of the Tokamak to the various diagnostic areas, where they are controlled and acquired data is processed. This mainly includes the areas such as ports, port cells, gallery, diagnostics enclosures and cubicle areas. The diagnostics port plugs encloses the front end of the diagnostic systems and the diagnostics building houses the diagnostics equipment, instrumentation and control cubicles. There are several systems providing services to diagnostics. These mainly include ITER buildings, electrical power services, cooling water services, Heating Ventilation and Air Conditioning (HVAC), vacuum services, liquid and gas distribution services, cable engineering, de-tritiation systems, control cubicles, etc. Requirements of these service systems have to be defined, even though many of the diagnostics are at an early stage of development. It is a real challenge to define and to design diagnostics systems considering the constraints imposed by these service systems. This paper summarizes the provision of these services to the individual diagnostics and diagnostics areas

  19. ITER diagnostics ex-vessel engineering services

    International Nuclear Information System (INIS)

    Arumugam, A.P.; Walker, C.I.; Andrew, P.; Barnsley, R.; Beltran, D.; Bertalot, L.; Dammann, A.; Direz, M.F.; Drevon, J.M.; Encheva, A.; Giacomin, T.; Hourtoule, J.; Kuehn, I.; Lanza, R.; Levesy, B.; Maquet, P.; Patel, K.M.; Patisson, L.; Pitcher, C.S.; Portales, M.

    2013-01-01

    Highlights: • This paper describes about the ITER diagnostics ex-vessel engineering services. • It describes various diagnostics systems, its location and its environment. • Diagnostics interfaces with other services such as the buildings, HVAC, electrical services, cooling water, vacuum, liquid and gas distribution. • All the interfaces with these services are identified and defined. • Buildings services for diagnostics, such as penetrations, local shielding, embedment and temperature control are discussed. -- Abstract: Extensive diagnostics systems will be installed on the ITER machine to provide the measurements necessary to control, evaluate and optimize plasma performance in ITER and to further the understanding of plasma physics. These include measurements of temperature, density, impurity concentration, and particle and energy confinement times. ITER diagnostic systems extend from the center of the Tokamak to the various diagnostic areas, where they are controlled and acquired data is processed. This mainly includes the areas such as ports, port cells, gallery, diagnostics enclosures and cubicle areas. The diagnostics port plugs encloses the front end of the diagnostic systems and the diagnostics building houses the diagnostics equipment, instrumentation and control cubicles. There are several systems providing services to diagnostics. These mainly include ITER buildings, electrical power services, cooling water services, Heating Ventilation and Air Conditioning (HVAC), vacuum services, liquid and gas distribution services, cable engineering, de-tritiation systems, control cubicles, etc. Requirements of these service systems have to be defined, even though many of the diagnostics are at an early stage of development. It is a real challenge to define and to design diagnostics systems considering the constraints imposed by these service systems. This paper summarizes the provision of these services to the individual diagnostics and diagnostics areas

  20. Reactor vessel sealing plug

    International Nuclear Information System (INIS)

    Dooley, R.A.

    1986-01-01

    This invention relates to an apparatus and method for sealing the cold leg nozzles of a nuclear reactor pressure vessel from a remote location during maintenance and inspection of associated steam generators and pumps while the pressure vessel and refueling canal are filled with water. The apparatus includes a sealing plug for mechanically sealing the cold leg nozzle from the inside of a reactor pressure vessel. The sealing plugs include a primary and a secondary O-ring. An installation tool is suspended within the reactor vessel and carries the sealing plug. The tool telescopes to insert the sealing plug within the cold leg nozzle, and to subsequently remove the plug. Hydraulic means are used to activate the sealing plug, and support means serve to suspend the installation tool within the reactor vessel during installation and removal of the sealing plug

  1. Modelling the assessment of port wine stain parameters from skin surface temperature following a diagnostic laser pulse

    NARCIS (Netherlands)

    Gabay, S.; Lucassen, G. W.; Verkruysse, W.; van Gemert, M. J.

    1997-01-01

    Laser treatment of port wine stains (PWS) has become an established clinical modality over the past decade. However, in some cases full clearance of the PWS cannot be achieved. To improve the clinical results, it is necessary to match the laser treatment parameters to the PWS anatomy on an

  2. Ports Initiative

    Science.gov (United States)

    EPA's Ports Initiative works in collaboration with the port industry, communities, and government to improve environmental performance and increase economic prosperity. This effort helps people near ports breath cleaner air and live better lives.

  3. Drill pipe bridge plug

    International Nuclear Information System (INIS)

    Winslow, D.W.; Brisco, D.P.

    1991-01-01

    This patent describes a method of stopping flow of fluid up through a pipe bore of a pipe string in a well. It comprises: lowering a bridge plug apparatus on a work string into the pipe string to a position where the pipe bore is to be closed; communicating the pipe bore below a packer of the bridge plug apparatus through the bridge plug apparatus with a low pressure zone above the packer to permit the fluid to flow up through the bridge plug apparatus; engaging the bridge plug apparatus with an internal upset of the pipe string; while the fluid is flowing up through the bridge plug apparatus, pulling upward on the work string and the bridge plug apparatus and thereby sealing the packer against the pipe bore; isolating the pipe bore below the packer from the low pressure zone above the packer and thereby stopping flow of the fluid up through the pipe bore; disconnecting the work string from the bridge plug apparatus; and maintaining the bridge plug apparatus in engagement with the internal upset and sealed against the pipe bore due to an upward pressure differential applied to the bridge plug apparatus by the fluid contained therebelow

  4. Tube plug removal machine

    International Nuclear Information System (INIS)

    Hawkins, P.J.

    1987-01-01

    In a nuclear steam generator wherein some faulty tubes have been isolated by mechanical plugging, to remove a selected plug without damaging the associated tube, a plug removal machine is used. The machine drills into a plug portion with a tap drill bit having a drill portion a tap portion and a threaded portion, engaging that plug portion with the threaded portion after the drilled hole has been threaded by the tap portion thereof, and removing a portion of the plug in the tube with a counterbore drill bit mounted concentrically about the tap drill bit. A trip pin and trip spline disengage the tap drill bit from the motor. The counterbore drill bit is thereafter self-centered with respect to the tube and plug about the now stationary tap drill bit. After a portion of the plug has been removed by the counterbore drill bit, pulling on the top drill bit by grippers on slots will remove the remaining plug portion from the tube. (author)

  5. [Analysis for serological diagnostic results of syphilis among entry personnel in Beijing port during 2012-2014].

    Science.gov (United States)

    Feng, M X; Sun, F J; Wang, F; Wang, K L; Liu, M

    2016-06-18

    To analyze the results of syphilis specific serological tests among entry personnel in Beijing port during year 2012-2014 in order to provide evidence for the prevention and control of syphilis. Demographics data and syphilis specific test results of entry personnel were obtained from the information system of Beijing International Travel Healthcare Center and input into Excel 2016. Database for entry personnel was built up accordingly and was analyzed by IBM SPSS22.0. The number of entry personnel in Beijing port during year 2012-2014 was 106 302 person-time. According to the evaluation criteria, 71 308 persons were recruited and analyzed, of whom 277 were tested serologically positive and the total prevalence was 0.39% (95% CI: 0.34%-0.43%). The prevalence was highest in the persons aged 40-49 years (0.81%) and was higher in males (0.50%) than in females (0.23%). The persons from Africa held higher prevalence (1.27%) than from other five regions. As multivariate logical regression analysis indicated that the risk of syphilis infection was 10.38 times more in the persons aged 40-49 years than in the persons 0.05). Twenty-seven seropositive cases were found within 6 246 entry persons who were tested repeatedly during the research period, 9 of which were seroconversion cases so that the cumulative conversion rate was 0.14% (9/6 228). The average conversion time was (6.3±3.0) months. There was no statistical significance between the cumulative seroconversion rates of the persons with different genders and nationalities (P of Fisher's exact test>0.05). Serological detection of syphilis for entry personnel in Beijing port and syphilis-related health education should be reinforced to reduce the risk of disease importing and spreading, protect susceptible subjects and promote health.

  6. Removable pipeline plug

    International Nuclear Information System (INIS)

    Vassalotti, M.; Anastasi, F.

    1984-01-01

    A removable plugging device for a pipeline, and particularly for pressure testing a steam pipeline in a boiling water reactor, wherein an inflatable annular sealing member seals off the pipeline and characterized by radially movable shoes for holding the plug in place, each shoe being pivotally mounted for self-adjusting engagement with even an out-of-round pipeline interior

  7. Retained Herrick Plug

    Directory of Open Access Journals (Sweden)

    Justin B. Hellman

    2018-05-01

    Full Text Available A 79-year-old female with a history of keratoconjunctivitis sicca presented with several years of epiphora of both eyes. Thirteen years earlier, intracanalicular Herrick lacrimal plugs (Lacrimedics, Eastsound, WA, USA had been placed in both eyes to treat her dry eye syndrome. After 13 years the patient felt the epiphora was intolerable and underwent endoscopic dacryocystorhinostomy (DCR of the left, then the right side. Intraoperatively, during the right endoscopic DCR, a Herrick lacrimal plug was found in the common canaliculus into the lacrimal sac. Postoperatively, the patient did well with improved epiphora. The Herrick plug is designed to be intracanalicular, and this case illustrates that the plug can migrate and be retained for many years. Collared punctal plugs have a lower risk of this type of complication.

  8. ITER lower port systems integration

    Energy Technology Data Exchange (ETDEWEB)

    Levesy, B., E-mail: bruno.levesy@iter.org [ITER Organization, CS 90 046, 13067 St Paul Lez Durance Cedex (France); Baker, D.; Boussier, B.; Bryan, S.; Cordier, J.J.; Dremel, M.; Dell' Orco, G.; Daly, E.; Doshi, B.; Jeannoutot, T.; Friconneau, J.P.; Gliss, C.; Le Barbier, R.; Lachevre, F.; Loughlin, M.; Martin, A.; Martins, J.P.; Maruyama, S.; Palmer, J.; Reichle, R. [ITER Organization, CS 90 046, 13067 St Paul Lez Durance Cedex (France)

    2011-10-15

    The lower port systems are installed inside the vacuum vessel lower ports and in the adjacent port cells. The vacuum vessel ports and penetrations are allocated as follow: -4 ports dedicated to remote handling of the divertor cassettes, contain diagnostics racks and divertor cooling pipes. -5 ports connecting the main vessel to the torus cryopumps, contain divertor cooling pipes, pellet and gas injection pipes and vertical stabilization coil feeders. -3 penetrations connecting torus cryopumps are connected to the vacuum vessel by branch pipes. -Specific penetrations for divertor cooling lines, in-vessel viewing and glow discharge systems. The general layout of the port systems has been revised recently to improve the cryopump (8 t weight, 1.8 m diameter and 2.5 m long) maintenance scheme with remote handling tools and integrate the in-vessel vertical stabilization coil feeders. The port allocation, the pumping ports design, and interfaces in-between ports and cryostat and in-between cryopumps and cryostat have been up-dated. The integration inside the 18 port cells (11 m x 4 m each) has been reviewed to avoid clashes in between systems and to fix the openings in the port cell concrete walls. The new layout integrates safety and neutron-shielding requirements as well as remote handling and maintenance compatibility for the different systems. The paper presents the up-dated integration of the lower port systems inside the ports and the port cells. Interfaces of the port systems with the vacuum vessel, the cryostat and the port cells are described.

  9. Design progress of the VV sectors and ports towards the ITER construction

    International Nuclear Information System (INIS)

    Utin, Yu.; Ioki, K.; Bachmann, C.

    2007-01-01

    The ITER vacuum vessel (VV) is an all-welded torus-shaped double-wall structure with stiffening ribs between the shells. The VV main function is to provide the high-vacuum and primary confinement boundary. The vessel also supports in-vessel components such as the blanket modules and the divertor cassettes. Along with these components, the VV provides radiation shielding - the neutron heat is removed by water circulating between the shells. To satisfy the manufacture and assembly needs, the VV consists of nine sectors. To provide access inside the vessel for auxiliary plasma heating, diagnostics, vacuum pumping and other needs, the VV is equipped with upper, equatorial and lower ports. The upper and regular equatorial ports are occupied with the port plugs. In addition, there are three ports at the equatorial level dedicated for neutral beam (NB) injection. As the ITER construction phase approaches, the VV design has been improved and developed in more detail with the focus on improved manufacture and reduced cost. Based on achievements of manufacturing studies being performed in cooperation with industry, design improvement of the typical VV sector (1) has been nearly finalized. Design improvement of other sectors is in progress - in particular, of the VV sectors 2 and 3 which interface with the NB ports. For all sectors, the concept for the in-wall shielding has been improved and developed in more detail. The design progress of VV sectors 2-3 has been accompanied by progress in the NB port design (including the beam-facing components to handle the heat flux input of the neutral beams). Design of other port structures has also progressed. Thus, supporting and sealing components between the port plugs and the ports have been further developed with the focus on improved structural performance and maintenance. At the lower level, there are full-size ports, and the pipe feedthroughs and local small penetrations. Design of all port structures at this level has

  10. Principal Ports

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Principal Ports are defined by port limits or US Army Corps of Engineers (USACE) projects, these exclude non-USACE projects not authorized for publication. The...

  11. Plug Load Data

    Data.gov (United States)

    National Aeronautics and Space Administration — We provide MATLAB binary files (.mat) and comma separated values files of data collected from a pilot study of a plug load management system that allows for the...

  12. Attributes of diagnostic tests to increase uptake of dual testing for syphilis and HIV in Port-au-Prince, Haiti.

    Science.gov (United States)

    Bristow, Claire C; Lee, Sung-Jae; Severe, Linda; William Pape, Jean; Javanbakht, Marjan; Scott Comulada, Warren; Klausner, Jeffrey D

    2017-03-01

    Introduction Syphilis and HIV screening is highly recommended for pregnant women and those at risk for infection. We used conjoint analysis to identify factors associated with testing preferences for HIV and syphilis infection. Methods We recruited 298 men and women 18 years and over seeking testing or care at GHESKIO (Haitian Study Group for Kaposi's Sarcoma and Opportunistic Infections) clinics. We created eight hypothetical dual HIV-syphilis test profiles varying across six dichotomous attributes. Participants were asked to rate each profile using Likert preference scales. An impact score was generated for each attribute by taking the difference between the preference scores for the preferred and non-preferred level of each attribute. Two-sided one-sample t-test was used to generate p values. Results Of 298 study participants, 61 (20.5%) were male. Of 237 females, 49 (20.7%) were pregnant. Cost (free vs. US$4; p syphilis testing preferences for this study sample in Port-au-Prince prioritized cost, single fingerprick, laboratory-based testing and timeliness.

  13. Rotary plug seal

    International Nuclear Information System (INIS)

    Ito, Koji; Abiko, Yoshihiro.

    1981-01-01

    Purpose: To enable fuel exchange even upon failure of regular seals and also to enable safety seal exchange by the detection of the reduction in the contact pressure of a rotary plug seal. Constitution: If one of a pair of regular tube seals for the rotary plug is failed during ordinary operation of a FBR type reactor, the reduction in the contact pressure of the seal to the plug gibbousness is detected by a pressure gauge and a solenoid valve is thereby closed. Thus, a back-up-tube seal provided above or below the tube seal is press-contacted by way of argon gas to the gibbousness to enter into operation state and lubricants are supplied from an oil tank. In such a structure, the back-up-tube seal is operated before the failure of the tube seal to enable to continue the fuel exchange work, as well as safety exchange for the tube seal. (Moriyama, K.)

  14. Characterization of the radiation field and evaluation of the nuclear responses in the ITER cryopump port cell

    International Nuclear Information System (INIS)

    Moro, Fabio; Villari, Rosaria; Flammini, Davide; Podda, Salvatore; Antipenkov, Alexander; Dremel, Matthias; Levesy, Bruno; Loughlin, Michael; Cambi, Gilio; Cepraga, Dan Gabriel; Petrizzi, Luigino

    2016-01-01

    The ITER main vacuum system consists of six torus exhaust pumps integrated in the Cryostat through dedicated housings at the building B1 level. The Port Cell area outside the cryopump plug is affected by neutrons streaming through the housing structure and diagnostics penetrations. The aim of the study presented in this paper is to perform a complete assessment of the nuclear responses in the Cryopump Port Cell #12 by means of the MCNP-5 Monte Carlo code in a full 3-D geometry. The results of the neutronic analyses provide guidelines for the design and maintenance of the embedded components, ensuring their structural integrity and proper operation. Radiation transport calculations have been carried out to determine the radiation field inside the Port Cell through 3-D neutrons and gamma maps. Nuclear heating induced by neutrons and photons and the absorbed dose during the ITER lifetime on steel and silicon have been estimated in the Port Cell area, in order to assess the nuclear loads that the diagnostics and related electronic components have to withstand. Furthermore, the impact of the gamma-rays emitted by neutron-activated water circulating in the Primary Heat Transfer System have been evaluated on the Port Cell environment: 3-D maps of the gamma flux, nuclear loads on steel/silicon during plasma operation are provided.

  15. Characterization of the radiation field and evaluation of the nuclear responses in the ITER cryopump port cell

    Energy Technology Data Exchange (ETDEWEB)

    Moro, Fabio, E-mail: fabio.moro@enea.it [ENEA, Fusion Technical Unit, Nuclear Technologies Laboratory, 45th Enrico Fermi St., 00044 Frascati, Rome (Italy); Villari, Rosaria; Flammini, Davide; Podda, Salvatore [ENEA, Fusion Technical Unit, Nuclear Technologies Laboratory, 45th Enrico Fermi St., 00044 Frascati, Rome (Italy); Antipenkov, Alexander; Dremel, Matthias; Levesy, Bruno; Loughlin, Michael [ITER Organization, Route de Vinon sur Verdon, 13115 Saint Paul-lez-Durance (France); Cambi, Gilio; Cepraga, Dan Gabriel [Bologna University, Physics Department, 46th Irnerio St., I-401226 Bologna (Italy); Petrizzi, Luigino [European Commission, DG Research & Innovation G5, CDMA 00/030, B-1049 Brussels (Belgium)

    2016-11-01

    The ITER main vacuum system consists of six torus exhaust pumps integrated in the Cryostat through dedicated housings at the building B1 level. The Port Cell area outside the cryopump plug is affected by neutrons streaming through the housing structure and diagnostics penetrations. The aim of the study presented in this paper is to perform a complete assessment of the nuclear responses in the Cryopump Port Cell #12 by means of the MCNP-5 Monte Carlo code in a full 3-D geometry. The results of the neutronic analyses provide guidelines for the design and maintenance of the embedded components, ensuring their structural integrity and proper operation. Radiation transport calculations have been carried out to determine the radiation field inside the Port Cell through 3-D neutrons and gamma maps. Nuclear heating induced by neutrons and photons and the absorbed dose during the ITER lifetime on steel and silicon have been estimated in the Port Cell area, in order to assess the nuclear loads that the diagnostics and related electronic components have to withstand. Furthermore, the impact of the gamma-rays emitted by neutron-activated water circulating in the Primary Heat Transfer System have been evaluated on the Port Cell environment: 3-D maps of the gamma flux, nuclear loads on steel/silicon during plasma operation are provided.

  16. Final case for a stainless steel diagnostic first wall on ITER

    Science.gov (United States)

    Pitts, R. A.; Bazylev, B.; Linke, J.; Landman, I.; Lehnen, M.; Loesser, D.; Loewenhoff, Th.; Merola, M.; Roccella, R.; Saibene, G.; Smith, M.; Udintsev, V. S.

    2015-08-01

    In 2010 the ITER Organization (IO) proposed to eliminate the beryllium armour on the plasma-facing surface of the diagnostic port plugs and instead to use bare stainless steel (SS), simplifying the design and providing significant cost reduction. Transport simulations at the IO confirmed that charge-exchange sputtering of the SS surfaces would not affect burning plasma operation through core impurity contamination, but a second key issue is the potential melt damage/material loss inflicted by the intense photon radiation flashes expected at the thermal quench of disruptions mitigated by massive gas injection. This paper addresses this second issue through a combination of ITER relevant experimental heat load tests and qualitative theoretical arguments of melt layer stability. It demonstrates that SS can be employed as material for the port plug plasma-facing surface and this has now been adopted into the ITER baseline.

  17. Final case for a stainless steel diagnostic first wall on ITER

    International Nuclear Information System (INIS)

    Pitts, R.A.; Bazylev, B.; Linke, J.; Landman, I.; Lehnen, M.; Loesser, D.; Loewenhoff, Th.; Merola, M.; Roccella, R.; Saibene, G.; Smith, M.; Udintsev, V.S.

    2015-01-01

    In 2010 the ITER Organization (IO) proposed to eliminate the beryllium armour on the plasma-facing surface of the diagnostic port plugs and instead to use bare stainless steel (SS), simplifying the design and providing significant cost reduction. Transport simulations at the IO confirmed that charge-exchange sputtering of the SS surfaces would not affect burning plasma operation through core impurity contamination, but a second key issue is the potential melt damage/material loss inflicted by the intense photon radiation flashes expected at the thermal quench of disruptions mitigated by massive gas injection. This paper addresses this second issue through a combination of ITER relevant experimental heat load tests and qualitative theoretical arguments of melt layer stability. It demonstrates that SS can be employed as material for the port plug plasma-facing surface and this has now been adopted into the ITER baseline

  18. Final case for a stainless steel diagnostic first wall on ITER

    Energy Technology Data Exchange (ETDEWEB)

    Pitts, R.A., E-mail: richard.pitts@iter.org [ITER Organization, Route de Vinon-sur-Verdon, CS 90 04, 613067 St. Paul Lez Durance Cedex (France); Bazylev, B. [Karlsruhe Institute of Technology, IHM, P.O. Box 3640, 76021 Karlsruhe (Germany); Linke, J. [Forschungszentrum Jülich GmbH, Institute of Energy and Climate Research, 52425 Juelich (Germany); Landman, I. [Karlsruhe Institute of Technology, IHM, P.O. Box 3640, 76021 Karlsruhe (Germany); Lehnen, M. [ITER Organization, Route de Vinon-sur-Verdon, CS 90 04, 613067 St. Paul Lez Durance Cedex (France); Loesser, D. [Princeton Plasma Physics Laboratory, Princeton, NJ 08543 (United States); Loewenhoff, Th. [Forschungszentrum Jülich GmbH, Institute of Energy and Climate Research, 52425 Juelich (Germany); Merola, M.; Roccella, R. [ITER Organization, Route de Vinon-sur-Verdon, CS 90 04, 613067 St. Paul Lez Durance Cedex (France); Saibene, G. [Fusion for Energy Joint Undertaking, Josep Pla no. 2 – T B3 7/01, Barcelona 08019 (Spain); Smith, M. [Princeton Plasma Physics Laboratory, Princeton, NJ 08543 (United States); Udintsev, V.S. [ITER Organization, Route de Vinon-sur-Verdon, CS 90 04, 613067 St. Paul Lez Durance Cedex (France)

    2015-08-15

    In 2010 the ITER Organization (IO) proposed to eliminate the beryllium armour on the plasma-facing surface of the diagnostic port plugs and instead to use bare stainless steel (SS), simplifying the design and providing significant cost reduction. Transport simulations at the IO confirmed that charge-exchange sputtering of the SS surfaces would not affect burning plasma operation through core impurity contamination, but a second key issue is the potential melt damage/material loss inflicted by the intense photon radiation flashes expected at the thermal quench of disruptions mitigated by massive gas injection. This paper addresses this second issue through a combination of ITER relevant experimental heat load tests and qualitative theoretical arguments of melt layer stability. It demonstrates that SS can be employed as material for the port plug plasma-facing surface and this has now been adopted into the ITER baseline.

  19. Providing free autopoweroff plugs

    DEFF Research Database (Denmark)

    Jensen, Carsten Lynge; Hansen, Lars Gårn; Fjordbak, Troels

    2012-01-01

    Experimental evidence of the effect of providing households with cheap energy saving technology is sparse. We present results from a field experiment in which autopoweroff plugs were provided free of charge to randomly selected households. We use propensity score matching to find treatment effects...

  20. Fuel rod end plug

    International Nuclear Information System (INIS)

    McGeary, R.K.; Bucher, G.D.

    1989-01-01

    This patent describes an end plug for welded disposition within the end of a tube. It comprises a circumferentially extending, axially oriented land surface, having a radial extent defined by means of a first predetermined dimension, for disposition within the end of the tube; a circumferentially extending, axially oriented land surface, having a radial extent defined by means of a second predetermined dimension which is greater than the first predetermined dimension, for disposition outside of the end of the tube. The second land surface being disposed upstream of the first land surface; an annularly extending, radially oriented shoulder portion, defined at the downstream end of the second land surface and having a radially inward depth which is greater than the difference defined between the first and second radial dimensions of the first and second land surfaces, for engaging the end of the tube in a butt contact fashion; and annular groove means defined between the upstream end of the first land surface and the shoulder portion of the end plug, for eliminating porosity defects normally developed within a weldment defined between the tube end and the end plug when the end plug is welded within the tube end, and including a conical surface which extends radially outwardly from the innermost radial depth extent of the shoulder portion to the upstream end of the first land surface

  1. Intake port

    Science.gov (United States)

    Mendler, Edward Charles

    2005-02-01

    The volumetric efficiency and power of internal combustion engines is improved with an intake port having an intake nozzle, a venturi, and a surge chamber. The venturi is located almost halfway upstream the intake port between the intake valves and the intake plenum enabling the venturi throat diameter to be exceptionally small for providing an exceptionally high ram velocity and an exceptionally long and in turn high efficiency diffuser flowing into the surge chamber. The intake port includes an exceptionally large surge chamber volume for blow down of the intake air into the working cylinder of the engine.

  2. Reactor vessel sealing plug

    International Nuclear Information System (INIS)

    Dooley, R.A.

    1986-01-01

    An apparatus is described for sealing a cold leg nozzle of a nuclear reactor pressure vessel from a remote location comprising: at least one sealing plug for mechanically sealing the nozzle from the inside of the reactor pressure vessel. The sealing plug includes a plate and a cone assembly having an end part receptive in the nozzle, the plate being axially moveable relative to the cone assembly. The plate and cone assembly have confronting bevelled edges defining an opening therebetween. A primary O-ring is disposed about the opening and is supported on the bevelled edges, the plate being guidably mounted to the cone assembly for movement toward the cone assembly to radially expand the primary O-ring into sealing engagement with the nozzle. A means is included for providing relative movement between the outer plate and the cone assembly

  3. Preliminary Calculations of Shutdown Dose Rate for the CTS Diagnostics System

    DEFF Research Database (Denmark)

    Klinkby, Esben Bryndt; Nonbøl, Erik; Lauritzen, Bent

    2015-01-01

    DTU and IST 2 are partners in the design of a collective Thomson Scattering (CTS) diagnostics for ITER through a contract with F4E. The CTS diagnostic utilizes probing radiation of ~60 GHz emitted into the plasma and, using a mirror, collects the scattered radiation by an array of receivers. Having...... on supplying input which affect the system design. Examples include: - Heatloads on plasma facing mirrors and preliminary stress and thermal analysis - Port plug cooling requirements and it's dependence on system design (in particular blanket cut-out) - Shutdown dose-rate calculations (relative analysis...

  4. Status of the R&D activities to the design of an ITER core CXRS diagnostic system

    Energy Technology Data Exchange (ETDEWEB)

    Mertens, Philippe, E-mail: ph.mertens@fz-juelich.de [Institute of Energy and Climate Research IEK-4 (Plasma Physics), Forschungszentrum Jülich (FZJ), Trilateral Euregio Cluster, D-52425 Jülich (Germany); Castaño Bardawil, David A. [Institute of Energy and Climate Research IEK-4 (Plasma Physics), Forschungszentrum Jülich (FZJ), Trilateral Euregio Cluster, D-52425 Jülich (Germany); Baross, Tétény [Wigner Research Centre for Physics (Wigner RCP), HU-1121 Budapest (Hungary); Biel, Wolfgang; Friese, Sebastian [Institute of Energy and Climate Research IEK-4 (Plasma Physics), Forschungszentrum Jülich (FZJ), Trilateral Euregio Cluster, D-52425 Jülich (Germany); Hawkes, Nick [Culham Centre for Fusion Energy (CCFE), Culham OX14 3DB (United Kingdom); Jaspers, Roger J.E. [Eindhoven University of Technology (TU/e), PO Box 513, NL-5600 MB Eindhoven (Netherlands); Kotov, Vladislav; Krasikov, Yury; Krimmer, Andreas; Litnovsky, Andrey; Marchuk, Oleksander; Neubauer, Olaf [Institute of Energy and Climate Research IEK-4 (Plasma Physics), Forschungszentrum Jülich (FZJ), Trilateral Euregio Cluster, D-52425 Jülich (Germany); Offermanns, Guido [Zentralinstitut für Engineering, Elektronik und Analytik ZEA-1 (Engineering and Technology), FZJ, Trilateral Euregio Cluster, D-52425 Jülich (Germany); Panin, Anatoly [Institute of Energy and Climate Research IEK-4 (Plasma Physics), Forschungszentrum Jülich (FZJ), Trilateral Euregio Cluster, D-52425 Jülich (Germany); and others

    2015-10-15

    Highlights: • The CXRS diagnostic for the core plasma of ITER will provide observation of the dedicated diagnostic beam (DNB) over a wide radial range, roughly r/a = 0.7 to 0. • A high performance (étendue × transmission, dynamic range) is expected for the port plug system since the beam attenuation is large and the background light omnipresent. • The design is particularly challenging in view of the ITER environment, especially with respect to the first mirror which faces the plasma. • The current status of development is presented by detailing several sub-systems before a four years design phase under an FPA between F4E and the ITER core CXRS Consortium (IC3). - Abstract: The CXRS (Charge-eXchange Recombination Spectroscopy) diagnostic for the core plasma of ITER will be designed to provide observation of the dedicated diagnostic beam (DNB) over a wide radial range, roughly from a normalised radius r/a = 0.7 to close to the plasma axis. The collected light will be transported through the Upper Port Plug #3 (UPP3) to a bundle of fibres and ultimately to a set of remote spectrometers. The design is particularly challenging in view of the ITER environment of particle, heat and neutron fluxes, temperature cycles, electromagnetic loads, vibrations, expected material degradation and fatigue, constraints against tritium penetration, integration in the plug and limited opportunities for maintenance. Moreover, a high performance (étendue × transmission, dynamic range) is expected for the port plug system since the beam attenuation is large and the background light omnipresent, especially in terms of bremsstrahlung, line radiation and reflections. The present contribution will give an overview of the current status and activities which deal with the core CXRS system, summarising the investigations which have taken place before entering the actual development and design phase.

  5. Diagnostics

    DEFF Research Database (Denmark)

    Donné, A.J.H.; Costley, A.E.; Barnsley, R.

    2007-01-01

    of the measurements—time and spatial resolutions, etc—will in some cases be more stringent. Many of the measurements will be used in the real time control of the plasma driving a requirement for very high reliability in the systems (diagnostics) that provide the measurements. The implementation of diagnostic systems...... on ITER is a substantial challenge. Because of the harsh environment (high levels of neutron and gamma fluxes, neutron heating, particle bombardment) diagnostic system selection and design has to cope with a range of phenomena not previously encountered in diagnostic design. Extensive design and R......&D is needed to prepare the systems. In some cases the environmental difficulties are so severe that new diagnostic techniques are required. The starting point in the development of diagnostics for ITER is to define the measurement requirements and develop their justification. It is necessary to include all...

  6. Major aspects of the design of a first mirror for the ITER core CXRS diagnostics

    International Nuclear Information System (INIS)

    Krasikov, Yury; Panin, Anatoly; Biel, Wolfgang; Krimmer, Andreas; Litnovsky, Andrey; Mertens, Philippe; Neubauer, Olaf; Schrader, Michael

    2015-01-01

    Highlights: • Availability, technological issues, and changes in the ScMo structure to be solved in future. • Developed passively cooled mirror is a workable, flexible, scalable and robust concept. • The generic upper port plug is to be considerable customized. - Abstract: The ITER core charge exchange recombination spectroscopy diagnostics (cCXRS) occupies the vacuum vessel upper port #3 and includes, in its generic version, the following in-vessel components: an optical mirror system, a shutter, the diagnostic first wall and the neutron shielding block. The most vulnerable diagnostic mirror is obviously the first one (M1) directly observing the plasma. The M1 reference option is made of a single crystalline molybdenum (ScMo). The paper indicates major aspects influencing the first mirror design and identifies the most reasonable and reliable concept for cCXRS M1 at present. The applicability of the option presented is determined by many reasons, and especially, by the ITER generic upper port plug and its customization flexibility. The largest dimension of the mirror polished face is ∼300 mm. Such large ScMo workpieces are currently not available on the market. The mirror should be designed as an assembly of several ScMo pieces joined together. The M1 design is supported by multifield thermal, electromagnetic and structural analyses. The performed study confirms the feasibility of the proposed solutions. At the same time, the paper indicates numerous technological issues of the M1 unit to be solved in future.

  7. Major aspects of the design of a first mirror for the ITER core CXRS diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Krasikov, Yury, E-mail: y.krasikov@fz-juelich.de; Panin, Anatoly; Biel, Wolfgang; Krimmer, Andreas; Litnovsky, Andrey; Mertens, Philippe; Neubauer, Olaf; Schrader, Michael

    2015-10-15

    Highlights: • Availability, technological issues, and changes in the ScMo structure to be solved in future. • Developed passively cooled mirror is a workable, flexible, scalable and robust concept. • The generic upper port plug is to be considerable customized. - Abstract: The ITER core charge exchange recombination spectroscopy diagnostics (cCXRS) occupies the vacuum vessel upper port #3 and includes, in its generic version, the following in-vessel components: an optical mirror system, a shutter, the diagnostic first wall and the neutron shielding block. The most vulnerable diagnostic mirror is obviously the first one (M1) directly observing the plasma. The M1 reference option is made of a single crystalline molybdenum (ScMo). The paper indicates major aspects influencing the first mirror design and identifies the most reasonable and reliable concept for cCXRS M1 at present. The applicability of the option presented is determined by many reasons, and especially, by the ITER generic upper port plug and its customization flexibility. The largest dimension of the mirror polished face is ∼300 mm. Such large ScMo workpieces are currently not available on the market. The mirror should be designed as an assembly of several ScMo pieces joined together. The M1 design is supported by multifield thermal, electromagnetic and structural analyses. The performed study confirms the feasibility of the proposed solutions. At the same time, the paper indicates numerous technological issues of the M1 unit to be solved in future.

  8. A plugging solution

    Energy Technology Data Exchange (ETDEWEB)

    Gen, O P; Azhigaliyev, G K; Dodonova, S Ye; Dyaltlova, N M; Novokhatskaya, I D; Ryabova, L I

    1984-01-01

    The purpose of the invention is to increase the durability of cement stone at 150 to 200C. The patent covers a plugging solution which consists of Portlandcement, sand and water. It additionally contains metal organic complexes of nitrylotrimethylphosphonic acid and organosiliconates of alkali or alkaline earth metals with the following component relationship in percent by mass: Portland cement, 42 to 43; sand, 27 to 28; metal organic complexes of nitrylotrimethylphosphonic acid, 0.01 to 1.5; organosiliconates of alkaline or alkaline earthmetals, 0.0025 to 0.375 and water, the remainder.

  9. Waste isolation pilot plant (WIPP) borehole plugging program description

    International Nuclear Information System (INIS)

    Christensen, C.L.; Hunter, T.O.

    1979-08-01

    The tests and experiments described attempt to provide a mix of borehole (with limited access) and in-mine (with relatively unlimited access) environments in which assessment of the various issues involved can be undertaken. The Bell Canyon Test provides the opportunity to instrument and analyze a plug in a high pressure region. The Shallow Hole Test permits application of best techniques for plugging and then access to both the top and bottom of the plug for further analysis. The Diagnostic Test Hole permits recovery of bench scale size samples for analysis and establishes an in-borehole laboratory in which to conduct testing and analysis in all strata from the surface into the salt horizon. The additional in mine experiments provide the opportunity to investigate in more detail specific effects on plugs in the salt region and allows evaluation of instrumentation systems

  10. Double-plug seismic connector

    International Nuclear Information System (INIS)

    Annoot, I.R.

    1984-01-01

    The double-plug seismic electric connector comprises an elongated insulating body. A male connector plug is at one end of the body and a female connector plug is at the opposite end of the body. Each plug has a pair of male and female contacts. A pair of spaced axial conductors is embedded within the insulating body for interconnecting the opposite male and female contacts. The inner end of a double-wire cable is embedded within the insulating body and each wire inner end is connected to one of the conductors

  11. Grooved tube plug rolls in

    International Nuclear Information System (INIS)

    Krausser, P.

    1991-01-01

    The removable plugs used to date by the Power Generation Group (KWU) of Siemens to seal defective steam generator tubes have a good track record. Their sealing principle is based on the elastic tensioning of three seal disks against the inside wall of the tube. Now a further removable plug is available -a roll-in plug with a metal-coated surface. It is particularly suitable for use in the roller-expanded zone of the tubes at the tube sheet. The plugs can be used in both Siemens-KWU steam generators and in steam generators manufactured in compliance with the guidelines of the ASME Code. (author)

  12. Ports Primer: 3.2 Port Governance

    Science.gov (United States)

    State and local governments are important players in port governance and in oversight of transportation projects that may affect ports. Private corporations may also play a role if they lease or own a terminal at a port.

  13. Mechanics Model of Plug Welding

    Science.gov (United States)

    Zuo, Q. K.; Nunes, A. C., Jr.

    2015-01-01

    An analytical model has been developed for the mechanics of friction plug welding. The model accounts for coupling of plastic deformation (material flow) and thermal response (plastic heating). The model predictions of the torque, energy, and pull force on the plug were compared to the data of a recent experiment, and the agreements between predictions and data are encouraging.

  14. Borehole Plugging Program. Plugging of ERDA No. 10 drill hole

    International Nuclear Information System (INIS)

    Gulick, C.W. Jr.

    1979-06-01

    A requirement exists to plug exploratory drill holes located in the proposed Waste Isolation Pilot Plant area of Southeastern New Mexico. Sandia Laboratories, in cooperation with the US Army Corps of Engineers, Waterways Experiment Station, Concrete Laboratory, developed pumpable and durable cement grouts. These grouts were successfully used to plug an existing drill hole in the area. Results of this project are presented, along with comments and conclusions

  15. Beam plug replacement and alignment under high radiation conditions for cold neutron facilities at Hanaro

    International Nuclear Information System (INIS)

    Yeong-Garp, Cho; Jin-Won, Shin; Jung-Hee, Lee; Jeong-Soo, Ryu

    2010-01-01

    Full text : The HANARO, an open-tank-in-pool type research reactor of a 30 MWth power in Korea, has been operating for 15 years since its initial criticality in February 1995. The beam port assigned for the cold neutron at HANARO had been used for an 8-m SANS without neutron guides until it was replaced by a cold neutron guide system in 2008. It was developed a cold neutron guide system for the delivery of cold neutrons from the cold neutron source in the reactor to the neutron scattering instruments in the guide hall. Since the HANARO has been operated from 1995, it was a big challenge to replace the existing plug and shutter with the new facilities under high radiation conditions. When the old plug was removed from the beam port in 2008, the radiation level was 230 mSv/hr at the end of beam port. In addition to that, there were more difficult situations such as the poor as-built dimensions of the beam port, limited work space and time constraint due to other constructions in parallel in the reactor hall. Before the removal of the old plug the level of the radiation was measured coming out through a small hole of the plug to estimate the radiation level during the removal of the old plug and installation of a new plug. Based on the measurement and analysis results, special tools and various shielding facilities were developed for the removal of old in-pile plug and the installation of the new in-pile plug assembly safely. In 2008, the old plug and shutter were successfully replaced by the new plug and shutter as shown in this article with a minimum exposure to the workers. A laser tracker system was also one of the main factors in our successful installation and alignment under high radiation conditions and limited work space. The laser tracker was used to measure and align all the mechanical facilities and the neutron guides with a minimum radiation exposure to workers. The alignment of all the guides and accessories were possible during reactor operation because

  16. Plug testing and removal tool

    International Nuclear Information System (INIS)

    Baric, T.J.; Kauric, C.E.; Garcia, C.N.

    1987-01-01

    This patent describes an apparatus for testing and removing a plug from an aperture in the cylindrical core barrel wall of a nuclear reactor. The plug has an enlarged head disposed along the wall in a narrow annular access space between the wall and a surrounding cylindrical thermal neutron shield. The apparatus comprises: fixed jaw means; movable jaw means pivotally connected to the fixed jaw means for movement with respect thereto between an open position accommodating reception of the plug head between the fixed and movable jaw means and a closed position for securely gripping the plug head between the fixed and movable jaw means; drive means carried by the fixed jaw means and coupled to the movable jaw means for effecting movement thereof between the open and closed positions thereof; and tensioning means carried by the jaw means for engagement with the core barrel when the jaw means are disposed in gripping engagement with the plug head for exerting on the jaw means and the gripped plug a predetermined force in a direction radially outwardly of the wall. The jaw means and the drive means and the tensioning means all have dimensions radially of the wall substantially less than the radial thickness of the access space to permit insertion into, movement within and removal from the access space

  17. The radiation analyses of ITER lower ports

    International Nuclear Information System (INIS)

    Petrizzi, L.; Brolatti, G.; Martin, A.; Loughlin, M.; Moro, F.; Villari, R.

    2010-01-01

    The ITER Vacuum Vessel has upper, equatorial, and lower ports used for equipment installation, diagnostics, heating and current drive systems, cryo-vacuum pumping, and access inside the vessel for maintenance. At the level of the divertor, the nine lower ports for remote handling, cryo-vacuum pumping and diagnostic are inclined downwards and toroidally located each every 40 o . The cryopump port has additionally a branch to allocate a second cryopump. The ports, as openings in the Vacuum Vessel, permit radiation streaming out of the vessel which affects the heating in the components in the outer regions of the machine inside and outside the ports. Safety concerns are also raised with respect to the dose after shutdown at the cryostat behind the ports: in such zones the radiation dose level must be kept below the regulatory limit to allow personnel access for maintenance purposes. Neutronic analyses have been required to qualify the ITER project related to the lower ports. A 3-D model was used to take into account full details of the ports and the lower machine surroundings. MCNP version 5 1.40 has been used with the FENDL 2.1 nuclear data library. The ITER 40 o model distributed by the ITER Organization was developed in the lower part to include the relevant details. The results of a first analysis, focused on cryopump system only, were recently published. In this paper more complete data on the cryopump port and analysis for the remote handling port and the diagnostic rack are presented; the results of both analyses give a complete map of the radiation loads in the outer divertor ports. Nuclear heating, dpa, tritium production, and dose rates after shutdown are provided and the implications for the design are discussed.

  18. Progress on the interface between UPP and CPRHS (Cask and Plug Remote Handling System) tractor/gripping tool for ITER

    International Nuclear Information System (INIS)

    Rosa, Elena V.; Rios, Luis; Queral, Vicente

    2013-01-01

    Highlights: ► UPP interface requirements in the plug RH extraction/insertion for ITER. ► Analyze of maximum misalignment between port duct and port cell. ► Friction study between plug skids and VV port/ramp rails during the plug transfer. ► Definition of the tolerance in the plug skids to avoid the plug jamming. ► Concepts of gripping tools based on one gripping point and avoiding force feedback. -- Abstract: EFDA finances a training programme called Goal Oriented Training Programme for Remote Handling (GOT RH), whose goal is to train engineers in Remote Handling for ITER. As part of this training programme, the conceptual design of the mechanical interface between Upper Port Plug (UPP) and Cask and Plug Remote Handling System (CPRHS) as well as the conceptual design of the needed tools for UPP Remote Handling is carried out. The paper presents the conceptual design of the UPP/Gripping Tool Interface. This includes the conceptual design of the gripping tool for introducing/removing the UPP in/from the ITER port and the mechanical features on both sides of the UPP/Gripping Tool Interface (e.g. alignment features, mechanical connectors, fasteners). In order to develop the design of the interface between UPP and CPRHS it is necessary to first identify the functional requirements of the Transfer Cask System (TCS) and the CPRHS, such as required degrees of freedom (DoF), required performances of system, geometrical constraints, loading conditions, alignment requirements, RAMI requirements. These requirements are the input data for the design of the interface between UPP and gripping tool and some of them are also described in the paper

  19. Three ports versus four ports laparoscopic cholecystectomy

    International Nuclear Information System (INIS)

    Shah, S.F.; Waqar, S.; Chaudry, M.A.; Hameed, S.

    2017-01-01

    To compare three ports laparoscopic cholecystectomy and four ports laparoscopic cholecystectomy in terms of complications, time taken to complete the procedure, hospital stay and cost effectiveness in local perspective. Methodology: This randomized control trial included 60 patients who underwent elective laparoscopic cholecystectomy at Department of Surgery, Pakistan Institute of Medical Sciences, Islamabad, Pakistan from January 2013 to June 2013. These patients were randomized on computer generated table of random numbers into group A and Group B. In Group A patients four ports were passed to perform laparoscopic cholecystectomy and in Group B patients three ports were passed to perform the procedure. Results: The mean age in both groups was 44 years (range 18-72). Three ports laparoscopic cholecystectomy (43 min) took less time to complete than four ports laparoscopic cholecystectomy (51 min). Patients in three ports laparoscopic cholecystectomy experienced less pain as compared to four ports group. The total additional analgesia requirement in 24 hours calculated in milligrams was less in three port laparoscopic cholecystectomy group as compared four port laparoscopic cholecystectomy group. The mean hospital stay in three port laparoscopic cholecystectomy group is 25 hours while the mean hospital stay in the four port laparoscopic cholecystectomy group is 28 hours. Conclusion: Three ports laparoscopic cholecystectomy is safe and effective procedure and it did not compromise the patient safety. (author)

  20. Principal Ports and Facilities

    Data.gov (United States)

    California Natural Resource Agency — The Principal Port file contains USACE port codes, geographic locations (longitude, latitude), names, and commodity tonnage summaries (total tons, domestic, foreign,...

  1. Principal Ports and Facilities

    Data.gov (United States)

    California Department of Resources — The Principal Port file contains USACE port codes, geographic locations (longitude, latitude), names, and commodity tonnage summaries (total tons, domestic, foreign,...

  2. Port of Rotterdam

    NARCIS (Netherlands)

    Veenstra, A.W.

    2014-01-01

    The port of Rotterdam is one of the largest ports in the World and has great significance for the Dutch and European economy. Newly appointed TU/e professor Albert Veenstra explains if and how the Port of Rotterdam is affected by the economic crisis. With other European ports closing in, what can

  3. Strategic port development

    DEFF Research Database (Denmark)

    Olesen, Peter Bjerg; Dukovska-Popovska, Iskra; Hvolby, Hans-Henrik

    2014-01-01

    While large global ports are recognised as playing a central role in many supply chains as logistic gateways, smaller regional ports have been more stagnant and have not reached the same level of development as the larger ports. The research literature in relation to port development is also...

  4. Port-Wine Stains

    Science.gov (United States)

    ... Safe Videos for Educators Search English Español Port-Wine Stains KidsHealth / For Parents / Port-Wine Stains What's ... Manchas de vino de oporto What Are Port-Wine Stains? A port-wine stain is a type ...

  5. Structural Analysis for an Upper Port of the ITER Vacuum Vessel

    International Nuclear Information System (INIS)

    Yun-Seok Hong; Kwon, T. K.; Ahn, H. J.; Kim, Y.K.; Lee, C.D.

    2006-01-01

    The ITER vacuum vessel (VV) has numerous openings for the port structures including upper, equatorial, and lower ports used for equipment installation, utility feed through, vacuum pumping, and access into the vessel for maintenance. Every upper port, slanted upward slightly, has a trapezoidal/rectangular cross-section and consists of a port stub, a stub extension and a port extension with a connecting duct. To investigate the structural integrity and to increase the structural reliability of the VV and ports, the structural analyses of the upper port structure have been performed. The global structural analysis of the upper port with the in-port components has been carried out. The local analyses of a tangential key, an upper port flange, a connecting duct and a sealing unit have been performed. The design loads are dead weight, normal and abnormal pressure load, electromagnetic load, and seismic load in consideration of the dynamic amplification factors. The stress analyses were performed in a nonlinear elastic approach taking into account the contact surface between port extension flange and port plug flange. Two advanced designs from the ITER international team have been reviewed. To verify the strength of the reinforcing ribs for the connecting duct and of the fastening/sealing units, the local analyses utilizing the sub-modeling technique have been performed. The ASME code and the ITER design criteria were applied for the evaluation of the structural analysis results from the global and local analyses. The clearance between a port and a plug to accommodate the plug deformation has been assessed. The upper port flange based on the original design could withstand design loads, but there could be a gap on the flange surface under the design condition. The modified flange design, which is under the bolt friction only without tangential key was proposed. The deflection of the plug for an advanced design with a removable flange is higher than that for the original

  6. Flat-port connectors

    KAUST Repository

    Alrashed, Mohammed

    2017-05-26

    Disclosed are various embodiments for connectors used with electronic devices, such as input and/or output ports to connect peripheral equipment or accessories. More specifically, various flat-port are provided that can be used in place of standard connectors including, but not limited to, audio jacks and Universal Serial Bus (USB) ports. The flat-port connectors are an alternate connection design to replace the traditional receptacle port (female-port), making the device more sealed creation more dust and water resistant. It is unique in the way of using the outer surfaces of the device for the electrical connection between the ports. Flat-port design can allow the manufacture of extremely thin devices by eliminating the side ports slots that take a lot of space and contribute to the increase thickness of the device. The flat-port receptacle improves the overall appearance of the device and makes it more resistant to dust and water.

  7. Management of Port Operations

    OpenAIRE

    Gheorghe BASANU; Georgiana NUKINA

    2011-01-01

    The Management of port operation requires the proper and efficient use of port facility, equipment for cargo handling, berth facilities, waterways and roads. It also entails the use of effective communications system, storage facilities, and dockworkers. The whole activities mentioned above form the bulk of port operations. The aspiration of port operator is to get cargo through the gateway of ports as fast as possible on to other modes of transport (rail or road) with a minimal cost to them ...

  8. Aspergillus fumigatus colonization of punctal plugs.

    Science.gov (United States)

    Tabbara, Khalid F

    2007-01-01

    Punctal plugs are used in patients with dry eye syndrome to preserve the tears. In this report, I present two cases of Aspergillus fumigatus colonization of punctal plugs. Observational series of two cases. Approval was obtained from the institutional review board. Two men aged 29 and 31 years developed black spots inside the hole of punctal plug, which looked like eyeliner deposits. The deposits inside the hole of the plug in each patient were removed and cultured. Cultures of the two punctal plugs black deposits grew A fumigatus. Bacterial cultures were negative. Colonization of the punctal plug hole with A fumigatus was observed in two cases. It is recommended that punctal plugs be removed in patients undergoing refractive or intraocular procedures or in patients who are receiving topical corticosteroids. Current punctal plugs should be redesigned to avoid the presence of an inserter hole.

  9. Shielding plug for LMFBR type reactors

    International Nuclear Information System (INIS)

    Hashiguchi, Ko.

    1979-01-01

    Purpose: To enable effective removal of liquid metals deposited, if any, in the gaps between a rotary plug and a fixed plug in LMFBR type reactors. Constitution: A plate incorporated with a heater and capable of projecting in a gap between a rotary plug and a fixed plug, and a scraper connected in perpendicular to it are provided to the rotary plug. Solidified liquid metals such as sodium deposited in the gap are effectively removed by the heating with the heater and the scraping action due to the rotation. (Horiuchi, T.)

  10. Port Authority Best Practices

    Science.gov (United States)

    Best practices for port authorities include near-port community collaboration, anti-idling policies, expanding off-peak hours, development of EMS, developing an emissions inventory, education, electric power and substituting trucking for rail or barge.

  11. US Ports of Entry

    Data.gov (United States)

    Department of Homeland Security — HSIP Non-Crossing Ports-of-Entry A Port of Entry is any designated place at which a CBP officer is authorized to accept entries of merchandise to collect duties, and...

  12. Flat-port connectors

    KAUST Repository

    Alrashed, Mohammed

    2017-01-01

    and water resistant. It is unique in the way of using the outer surfaces of the device for the electrical connection between the ports. Flat-port design can allow the manufacture of extremely thin devices by eliminating the side ports slots that take a lot

  13. Getting Port Governance Right

    DEFF Research Database (Denmark)

    de Langen, Peter; Saragiotis, Periklis

    2018-01-01

    This chapter discusses the relevance of ports for economic development and next identifies port governance as a critical determinant of a well-functioning port industry. While in the past decades privately owned terminal operating companies have emerged and contributed to more efficient supply ch...

  14. Refueling system with small diameter rotatable plugs

    International Nuclear Information System (INIS)

    Ritz, W.C.

    1987-01-01

    This patent describes a liquid-metal fastbreeder nuclear reactor comprising a reactor pressure vessel and closure head therefor, a reactor core barrel disposed within the reactor vessel and enclosing a reactor core having therein a large number of closely spaced fuel assemblies, and the reactor core barrel and the reactor core having an approximately concentric circular cross-sectional configuration with a geometric center in predetermined location within the reactor vessel. The improved refueling system described here comprises: a large controllably rotatable plug means comprising the substantial portion of the closure head, a reactor upper internals structure mounted from the large rotatable plug means. The large rotatable plug means has an approximately circular configuration which approximates the cross-sectional configuration of the reactor core barrel with a center of rotation positioned a first predetermined distance from the geometric center of the reactor core barrel so that the large rotatable plug means rotates eccentrically with respect to the reactor core barrel; a small controllably rotatable plug means affixed to the large rotatable plug means and rotatable with respect thereto. The small rotatable plug means has a center of rotation which is offset a second predetermined distance from the rotational center of the large rotatable plug means so that the small rotatable plug means rotates eccentrically with respect to the large rotatable plug means

  15. Shipping emissions in ports

    OpenAIRE

    Merk, Olaf

    2014-01-01

    Shipping emissions in ports are substantial, accounting for 18 million tonnes of CO2 emissions, 0.4 million tonnes of NOx, 0.2 million of SOx and 0.03 million tonnes of PM10 in 2011. Around 85% of emissions come from containerships and tankers. Containerships have short port stays, but high emissions during these stays. Most of CO2 emissions in ports from shipping are in Asia and Europe (58%), but this share is low compared to their share of port calls (70%). European ports have much less emi...

  16. Sea freight - Antwerp Port

    Directory of Open Access Journals (Sweden)

    NEACSU Nicoleta Andreea

    2017-01-01

    Full Text Available Shipping plays a vital role in achieving the movement of goods, both in terms of quantity and efficiency. This paper presents the role and advantages of shipping in the global economy and analyzes the development and Antwerp Port activity. Currently, the second most important trading port in Europe and 14th in the ranking of most important ports that handle containers worldwide, the Port of Antwerp, Belgium is a port in the heart of Europe, accessible to large sized vessels. 200 years of constructing infrastructure and logistics around the central location, as well as pressure from Rotterdam, that had an impact on the competitiveness of the port of Antwerp, all this led the port to occupy a leading position in the top rankings.

  17. Challenges of ITER diagnostic electrical services

    Energy Technology Data Exchange (ETDEWEB)

    Encheva, A., E-mail: anna.encheva@iter.org [ITER Organization, Route de Vinon sur Verdon, 13115 St Paul-Lez-Durance (France); Omran, H. [Oxford Technologies Ltd, 7 Nuffield Way, Abingdon OX14 1RL (United Kingdom); Pérez-Lasala, M. [The European Joint Undertaking for ITER and the Development of Fusion Energy, c/Josep Pla, n° 2, Torres Diagonal Litoral, Edificio B3, 08019 Barcelona (Spain); Alekseev, A. [Efremov Institute, Metallostroy, Doroga na Metallostroy, 3 bld., Saint-Petersburg 196641 (Russian Federation); Arshad, S. [The European Joint Undertaking for ITER and the Development of Fusion Energy, c/Josep Pla, n° 2, Torres Diagonal Litoral, Edificio B3, 08019 Barcelona (Spain); Bede, O. [Oxford Technologies Ltd, 7 Nuffield Way, Abingdon OX14 1RL (United Kingdom); Bender, S. [Efremov Institute, Metallostroy, Doroga na Metallostroy, 3 bld., Saint-Petersburg 196641 (Russian Federation); Bertalot, L.; Direz, M.-F.; Drevon, J.-M.; Jakhar, S.; Kaschuk, Y.; Komarov, V.; Lebarbier, R. [ITER Organization, Route de Vinon sur Verdon, 13115 St Paul-Lez-Durance (France); Lucca, F. [L.T. Calcoli SaS, Piazza Prinetti 26/B, 23807 Merate (Italy); Macklin, B.; Maquet, P. [ITER Organization, Route de Vinon sur Verdon, 13115 St Paul-Lez-Durance (France); Marin, A. [L.T. Calcoli SaS, Piazza Prinetti 26/B, 23807 Merate (Italy); Martin, A. [ITER Organization, Route de Vinon sur Verdon, 13115 St Paul-Lez-Durance (France); Mills, S. [Oxford Technologies Ltd, 7 Nuffield Way, Abingdon OX14 1RL (United Kingdom); and others

    2013-10-15

    Highlights: • A brief description of all major components part of diagnostic electrical services has been given. • The integration challenges have been presented. • Design assumptions and requirements for the components have been described. • The design of the conduit/loom and the relevant analysis has been highlighted. -- Abstract: Diagnostic electrical services provide the electrical infrastructure to serve diagnostic components installed on the ITER tokamak. This infrastructure is composed of cables, connectors, cable tails, looms, conduits and feedthroughs. The diagnostic services offer as well a shelter for various instrumentations – vacuum vessel (VV), blanket and divertor. The diagnostic sensors are located on the inner and outer VV wall, on blanket shield modules, divertor cassettes and in port plugs. They require electrical cabling to extract the measurement and, in some cases, to supply electrical power to the sensors. These cables run from the sensors to feedthroughs on the VV and the port interspace or cryostat. The design and integration of all components that are part of diagnostic electrical services is an important engineering activity that is being challenged by the multiple requirements and constraints which have to be satisfied while at the same time delivering the required diagnostic performance. The positioning of the components must correlate not only with their functional specifications but also with the design of the major ITER components. This is a particular challenge because not all systems have reached the same level of design maturity. This paper outlines the engineering challenges of ITER diagnostics electrical services. The environmental conditions inside the VV will have an important impact. Leading risks to these components include poor electrical contact at connectors, the effects of exposure to nuclear irradiation, such as material transmutation, heating, and generation of spurious electrical signals etc., failure due to

  18. Plug Load Behavioral Change Demonstration Project

    Energy Technology Data Exchange (ETDEWEB)

    Metzger, I.; Kandt, A.; VanGeet, O.

    2011-08-01

    This report documents the methods and results of a plug load study of the Environmental Protection Agency's Region 8 Headquarters in Denver, Colorado, conducted by the National Renewable Energy Laboratory. The study quantified the effect of mechanical and behavioral change approaches on plug load energy reduction and identified effective ways to reduce plug load energy. Load reduction approaches included automated energy management systems and behavioral change strategies.

  19. Nuclear fuel rod end plug weld inspection

    International Nuclear Information System (INIS)

    Parker, M. A.; Patrick, S. S.; Rice, G. F.

    1985-01-01

    Apparatus and method for testing TIG (tungsten inert gas) welds of end plugs on a sealed nuclear reactor fuel rod. An X-ray fluorescent spectrograph testing unit detects tungsten inclusion weld defects in the top end plug's seal weld. Separate ultrasonic weld inspection system testing units test the top end plug's seal and girth welds and test the bottom end plug's girth weld for penetration, porosity and wall thinning defects. The nuclear fuel rod is automatically moved into and out from each testing unit and is automatically transported between the testing units by rod handling devices. A controller supervises the operation of the testing units and the rod handling devices

  20. Multimeediaetendus : Opera Gets Plugged / Eve Arpo

    Index Scriptorium Estoniae

    Arpo, Eve

    2008-01-01

    Eesti Muusika- ja Teatriakadeemia lühiooperite õhtul "Opera Gets Plugged" etendunud lavastustest - Monika Mattieseni "DMeeter" ja Age Hirve "Tuleloitsija": Mõlema lavastaja ja projektijuht Liis Kolle

  1. Friction Pull Plug and Material Configuration for Anti-Chatter Friction Pull Plug Weld

    Science.gov (United States)

    Littell, Justin Anderson (Inventor)

    2016-01-01

    A friction pull plug is provided for use in forming a plug weld in a hole in a material. The friction pull plug includes a shank and a series of three frustoconical sections. The relative sizes of the sections assure that a central one of the sections defines the initial contact point between the hole's sides. The angle defined by the central one of the sections reduces or eliminates chatter as the plug is pulled into the hole.

  2. Radiation level analysis for the port cell of the ITER electron cyclotron-heating upper launcher

    Energy Technology Data Exchange (ETDEWEB)

    Weinhorst, Bastian, E-mail: bastian.weinhorst@kit.edu [KIT, Institute for Neutron Physics and Reactor Technology, Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen (Germany); Fischer, Ulrich; Lu, Lei [KIT, Institute for Neutron Physics and Reactor Technology, Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen (Germany); Strauss, Dirk; Spaeh, Peter; Scherer, Theo [KIT, Institute for Applied Materials, Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen (Germany); Leichtle, Dieter [F4E, Analysis & Codes/Technical Support Services, Josep Pla 2, Torres Diagonal Litoral B3, 08019 Barcelona (Spain)

    2016-11-01

    Highlights: • First detailed neutronic modelling of the ECHUL port cell with ECHUL equipment (including beam lines with diamond windows, the beam lines mounting box, conduit boxes and rails). • Three different bioshield port plug configurations and two different neutron source configurations are investigated. • Radiation Levels are calculated in the port cell, focusing on the position of the diamond window. • The dose rate in the port cell is below the limit for maintenance in the port cell. • The radiation level at the diamond window is very low and should not influence its performance. - Abstract: The electron cyclotron-heating upper launcher (ECHUL) will be installed in four upper ports of the ITER tokamak thermonuclear fusion reactor. Each ECHUL is able to deposit 8 MW power into the plasma for plasma mode stabilization via microwave beam lines. An essential part of these beam lines are the diamond windows. They are located in the upper port cell behind the bioshield to reduce the radiation levels to a minimum. The paper describes the first detailed neutronic modelling of the ECHUL port cell with ECHUL equipment. The bioshield plug is modelled including passageways for the microwave beam lines, piping and cables looms as well as rails and openings for ventilation. The port cell is equipped with the beam lines including the diamond windows, the beam lines mounting box, conduit boxes and rails. The neutrons are transported into the port cell starting from a surface source in front of the bioshield. Neutronic results are obtained for radiation levels in the port cell at different positions, mainly focusing on the diamond windows position. It is shown that the radiation level is below the limit for maintenance in the port cell. The radiation level at the diamond window is very low and should not influence its performance.

  3. Data port security lock

    Science.gov (United States)

    Quinby, Joseph D [Albuquerque, NM; Hall, Clarence S [Albuquerque, NM

    2008-06-24

    In a security apparatus for securing an electrical connector, a plug may be fitted for insertion into a connector receptacle compliant with a connector standard. The plug has at least one aperture adapted to engage at least one latch in the connector receptacle. An engagement member is adapted to partially extend through at least one aperture and lock to at least one structure within the connector receptacle.

  4. Principle plug design for deposition tunnels

    International Nuclear Information System (INIS)

    Haaramo, M.; Lehtonen, A.

    2009-06-01

    This report examines the plug structures to be built in the deposition tunnels of the repository. The deposition tunnels located below the depth of 400 metres have been used as input data. Each plug consists of a massive concrete structure. The planned maximum pressure acting on the plug is 7.5 MPa. It consists of 4.5 MPa of groundwater pressure and 3 MPa of swelling pressure of the backfill. Five different plug types have been examined. Two of them (butt and irregular plug) turned out to be difficult from the point of view of other works in the central and deposition tunnels. One type (straight plug) requires a lot of construction material. Wedge-shaped and dome plugs have been examined more carefully. The wedge shaped plug has advantageous properties in comparison with the dome plug, such as a three dimensional state of stress, the wedging effect which increases strength as pressure increases and larger tolerances for the excavation of the slot. Leakage water has a longer path through the wedge shaped plug than through the dome plug. Pressure load affects the wedge shaped plug, creating normal stresses, which are compressive along each coordinate axis. The long-term rise in temperature in the deposition tunnels can produce high extra stresses in all the plug alternatives. These stresses make it necessary to increase the strength of the concrete or the distance between the plug and the nearest deposition hole. The stability effects of different plug distances and deposition tunnel orientations have been examined. The plug does not significantly affect stresses in the surrounding bedrock or the stability of the bedrock. Stresses caused by excavation and temperature rise are decisive factors. A groundwater chloride content of 0-3% in the environment of the repository is used as input data. It affects the tightness of the concrete and the quality of the cement. Cement has to be sulphate resistant with a low pH value. Low pH results in the weakening of the corrosion

  5. Mastering Eclipse plug-in development

    CERN Document Server

    Blewitt, Alex

    2014-01-01

    If you are a Java developer who is familiar with the Eclipse plug-in environment, this book covers the advanced concepts that you need to know to achieve true expertise. Prior experience in creating Eclipse plug-ins is assumed for this book.

  6. Plugging regime in the pump limiter throat

    International Nuclear Information System (INIS)

    Ghendrih, P.; Grosman, A.; Samain, A.; Capes, H.; Morera, J.P.

    1988-08-01

    The plugging regime -with no outstreaming neutral flux- is studied for a closed configuration pump limiter (throat). We derive the plugging length and the neutral density build-up at the neutralizer plate. The analytical expressions are supported by numerical evidence. We find an improved efficiency related to the throat effect mainly due to neutral-sidewall interactions

  7. Plug-In Tutor Agents: Still Pluggin'

    Science.gov (United States)

    Ritter, Steven

    2016-01-01

    "An Architecture for Plug-in Tutor Agents" (Ritter and Koedinger 1996) proposed a software architecture designed around the idea that tutors could be built as plug-ins for existing software applications. Looking back on the paper now, we can see that certain assumptions about the future of software architecture did not come to be, making…

  8. Multiservice utility plug for remote fuel reprocessing

    International Nuclear Information System (INIS)

    Goldmann, L.H. Jr.; Jensen, D.A.

    1979-10-01

    This paper presents the design of a multiservice utility plug and drive system to be used for reliably engaging and disengaging all utility connections automatically that serve large portable equipment modules. The modules are arranged into a fuel processing production line within the Fuels and Materials Examination Laboratory. The utility plugs allow the modules to be easily replaced, rearranged or removed for maintenance

  9. Explosive plugging of nuclear heat exchangers

    International Nuclear Information System (INIS)

    Crossland, B.; Bahrani, A.S.; Townsley, W.J.

    1977-01-01

    Explosive welding is a well established process for cladding one metal on another or for welding tubes to tubeplates or lap welding, etc. Recently, the process has been adapted to plugging of heat exchangers in conventional and nuclear power plant, where it has already been accepted especially in situations where the access is difficult and remote from the site of plugging. The paper describes the explosive plugging techniques developed in the Department of Mechanical and Industrial Engineering of The Queen's University of Belfast for the reheater and superheater of the PFR, and for the reheater of the AGR. For the PFR a point charge system has been used which causes a spherical expansion of the plug, which gives two zones of welding. Initially for the much larger plug required for the AGR it was proposed to use a parallel stand-off welding set-up, but it proved difficult or impossible to avoid a crevice. Consequently, a rim charge set-up has been developed which gives a circular ring expansion of the plug with two zones of welding. Besides the problem of the design of the plug and explosive charge geometry it has also been necessary to consider the distortion of holes adjoining the hole in which a plug is welded. Bunging of adjoining holes in order to reduce the distortion has also been investigated

  10. Spatial Determinants of Import Traffic Distribution At Port Harcourt (Nigeria

    Directory of Open Access Journals (Sweden)

    Soddy I. Inyang

    2013-07-01

    Full Text Available This paper highlights the result of a study carried out to examine the Geographic determinants of import traffic distribution at the Port Harcourt Port. A substantial aspect of the study involved building a regression model to estimate import distribution from the Port. The import function was specified in log-linear form. The adequacy of the model was then tested; this, involved statistical experiments to obtain the R-squared, as well as t and f values. Further test on the adequacy of the nwdel was conducted through diagnostic exercises designed to check for inulticollinedrity and heteroscedasticity, in the data used. Results obtained show that road distance and manufacturing industries are significant Geographic determinants of import Cargo distribution at the study Port. It is therefore important to lake the two variables into account in any policy or planning exercise at Port Harcourt Port.

  11. Mixture for plugging absorption zones

    Energy Technology Data Exchange (ETDEWEB)

    Sitinkov, G V; Kovalenko, N G; Makarov, L V; Zinnatulchin, Ts Kh

    1981-01-17

    A mixture is proposed for plugging absorption zones. The mixture contains synthetic polymer and a solvent. So as to increase the penetrability of the mixture through a reduction in its viscosity and an increase in insulation properties, the compound contains either Capron or Neilon as the synthetic polyamide resin polmyer, and concentrated chloride as the solvent. The mixture is prepared in a special AzINMASh-30 unit (acid cart). After the mixture has been produced, it is injected into the borehole by means of an acid cart pump. So as to prevent coaggulation at the point when the mixture in injected into the stratum through tubes, the mixture is placed betwen chemically inert fluids, for example, a clay mortar. The inert and compressed fluids are injected by means of a cementing unit. The entire process of production and application of the mixture is simple and fully automated through the use of well-known equipment.

  12. Plug-in Hybrid Initiative

    Energy Technology Data Exchange (ETDEWEB)

    Goodman, Angie; Moore, Ray; Rowden, Tim

    2013-09-27

    Our main project objective was to implement Plug-in Electric Vehicles (PEV) and charging infrastructure into our electric distribution service territory and help reduce barriers in the process. Our research demonstrated the desire for some to be early adopters of electric vehicles and the effects lack of education plays on others. The response of early adopters was tremendous: with the initial launch of our program we had nearly 60 residential customers interested in taking part in our program. However, our program only allowed for 15 residential participants. Our program provided assistance towards purchasing a PEV and installation of Electric Vehicle Supply Equipment (EVSE). The residential participants have all come to love their PEVs and are more than enthusiastic about promoting the many benefits of driving electric.

  13. Port Stakeholder Summit: Advancing More Sustainable Ports (April 2014)

    Science.gov (United States)

    EPA's National Port Stakeholders Summit, Advancing More Sustainable Ports, focused on actions to protect air quality while reducing climate risk and supporting economic growth, making ports more environmentally sustainable.

  14. Concept development for the ITER equatorial port visible/infrared wide angle viewing system

    International Nuclear Information System (INIS)

    Reichle, R.; Beaumont, B.; Boilson, D.; Bouhamou, R.; Direz, M.-F.; Encheva, A.; Henderson, M.; Kazarian, F.; Lamalle, Ph.; Lisgo, S.; Mitteau, R.; Patel, K. M.; Pitcher, C. S.; Pitts, R. A.; Prakash, A.; Raffray, R.; Schunke, B.; Snipes, J.; Diaz, A. Suarez; Udintsev, V. S.

    2012-01-01

    The ITER equatorial port visible/infrared wide angle viewing system concept is developed from the measurement requirements. The proposed solution situates 4 viewing systems in the equatorial ports 3, 9, 12, and 17 with 4 views each (looking at the upper target, the inner divertor, and tangentially left and right). This gives sufficient coverage. The spatial resolution of the divertor system is 2 times higher than the other views. For compensation of vacuum-vessel movements, an optical hinge concept is proposed. Compactness and low neutron streaming is achieved by orienting port plug doglegs horizontally. Calibration methods, risks, and R and D topics are outlined.

  15. Status of the design of the ITER ECE diagnostic

    International Nuclear Information System (INIS)

    Taylor, G.; Austin, M. E.; Beno, J. H.; Danani, S.; Ellis, R. F.; Feder, R.; Hesler, J. L.; Hubbard, A. E.; Johnson, D. W.; Kumar, R.; Kumar, S.; Kumar, V.; Ouroua, A.; Pandya, H. K. B.; Phillips, P. E.; Roman, C.; Rowan, W. L.; Udintsev, V.; Vayakis, G.; Walsh, M.; Kubo, S.

    2015-01-01

    In this study, the baseline design for the ITER electron cyclotron emission (ECE) diagnostic has entered the detailed preliminary design phase. Two plasma views are planned, a radial view and an oblique view that is sensitive to distortions in the electron momentum distribution near the average thermal momentum. Both views provide high spatial resolution electron temperature profiles when the momentum distribution remains Maxwellian. The ECE diagnostic system consists of the front-end optics, including two 1000 K calibration sources, in equatorial port plug EP9, the 70-1000 GHz transmission system from the front-end to the diagnostics hall, and the ECE instrumentation in the diagnostics hall. The baseline ECE instrumentation will include two Michelson interferometers that can simultaneously measure ordinary and extraordinary mode ECE from 70 to 1000 GHz, and two heterodyne radiometer systems, covering 122-230 GHz and 244-355 GHz. Significant design challenges include 1) developing highly-reliable 1000 K calibration sources and the associated shutters/mirrors, 2) providing compliant couplings between the front-end optics and the polarization splitter box that accommodate displacements of the vacuum vessel during plasma operations and bake out, 3) protecting components from damage due to stray ECH radiation and other intense millimeter wave emission and 4) providing the low-loss broadband transmission system

  16. Port Harcourt Medical Journal

    African Journals Online (AJOL)

    Port Harcourt Medical Journal's objectives are to disseminate medical information from the College of Health Sciences, University of Port Harcourt and the rest of the national and international medical community; act as a medium for the articulation of research and findings from same as well as proceedings of medical ...

  17. The Flexible Port

    NARCIS (Netherlands)

    Taneja, P.

    2013-01-01

    Ports are beset with many uncertainties about their futures. They are confronted with new demands in terms of functions and scales, new external constraints, and changed expectations. The inability to adequately meet these demands can mean costly adaptations for a port, or loss of cargo and

  18. Port Stakeholder Summit - April 2014

    Science.gov (United States)

    EPA's National Port Stakeholders Summit, Advancing More Sustainable Ports, focused on actions to protect air quality while reducing climate risk and supporting economic growth, making ports more environmentally sustainable.

  19. Friction Pull Plug Welding in Aluminum Alloys

    Science.gov (United States)

    Brooke, Shane A.; Bradford, Vann

    2012-01-01

    NASA's Marshall Space Flight Center (MSFC) has recently invested much time and effort into the process development of Friction Pull Plug Welding (FPPW). FPPW, is a welding process similar to Friction Push Plug Welding in that, there is a small rotating part (plug) being spun and simultaneously pulled (forged) into a larger part. These two processes differ, in that push plug welding requires an internal reaction support, while pull plug welding reacts to the load externally. FPPW was originally conceived as a post proof repair technique for the Space Shuttle fs External Tank. FPPW was easily selected as the primary weld process used to close out the termination hole on the Constellation Program's ARES I Upper Stage circumferential Self-Reacting Friction Stir Welds (SR-FSW). The versatility of FPPW allows it to also be used as a repair technique for both SR-FSW and Conventional Friction Stir Welds. To date, all MSFC led development has been concentrated on aluminum alloys (2195, 2219, and 2014). Much work has been done to fully understand and characterize the process's limitations. A heavy emphasis has been spent on plug design, to match the various weldland thicknesses and alloy combinations. This presentation will summarize these development efforts including weld parameter development, process control, parameter sensitivity studies, plug repair techniques, material properties including tensile, fracture and failure analysis.

  20. Plug cementing: Horizontal to vertical conditions

    Energy Technology Data Exchange (ETDEWEB)

    Calvert, D.G.; Heathman, J.F.; Griffith, J.E.

    1995-12-31

    This paper presents an in-depth study of cement plug placement that was conducted with large-scale models for the improvement of plug cementing practices and plug integrity. Common hole and workstring geometries were examined with various rheology and density ratios between the drilling fluid and cement. The critical conditions dictating the difference between success and failure for various wellbore angles and conditions were explored, and the mechanisms controlling slurry movement before and after placement are now better understood. An understanding of these mechanisms allows the engineer to better tailor a design to specific hole conditions. Controversial concepts regarding plug-setting practices have been examined and resolved. The cumulative effects of density, rheology, and hole angle are major factors affecting plug success. While the Boycott effect and an extrusion effect were observed to be predominant in inclined wellbores, a spiraling or {open_quotes}roping{close_quotes} effect controls slurry movement in vertical wellbores. Ultimate success of a cement plug can be obtained if allowances are made for these effects in the job design, provided all other previously published recommended placement practices are followed. Results of this work can be applied to many sidetracking and plug-to-abandon operations. Additionally, the understanding of the fluid movement (creep) mechanisms holds potential for use in primary and remedial cementing work, and in controlling the placement of noncementitious fluids in the wellbore.

  1. EBR-II rotating plug seal maintenance

    International Nuclear Information System (INIS)

    Allen, K.J.

    1986-01-01

    The EBR-II rotating plug seals require frequent cleaning and maintenance to keep the plugs from sticking during fuel handling. Time consuming cleaning on the cover gas and air sides of the dip ring seal is required to remove oxidation and sodium reaction products that accumulate and stop plug rotation. Despite severely limited access, effective seal cleaning techniques have removed 11 800 lb (5 352 kg) of deposits from the seals since 1964. Temperature control modifications and repairs have also required major maintenance work. Suggested seal design recommendations could significantly reduce maintenance on future similar seals

  2. Diagnostics on Z (invited)

    International Nuclear Information System (INIS)

    Nash, T. J.; Derzon, M. S.; Chandler, G. A.; Fehl, D. L.; Leeper, R. J.; Porter, J. L.; Spielman, R. B.; Ruiz, C.; Cooper, G.; McGurn, J.

    2001-01-01

    The 100 ns, 20 MA pinch-driver Z is surrounded by an extensive set of diagnostics. There are nine radial lines of sight set at 12 o above horizontal and each of these may be equipped with up to five diagnostic ports. Instruments routinely fielded viewing the pinch from the side with these ports include x-ray diode arrays, photoconducting detector arrays, bolometers, transmission grating spectrometers, time-resolved x-ray pinhole cameras, x-ray crystal spectrometers, calorimeters, silicon photodiodes, and neutron detectors. A diagnostic package fielded on axis for viewing internal pinch radiation consists of nine lines of sight. This package accommodates virtually the same diagnostics as the radial ports. Other diagnostics not fielded on the axial or radial ports include current B-dot monitors, filtered x-ray scintillators coupled by fiber optics to streak cameras, streaked visible spectroscopy, velocity interferometric system for any reflector, bremsstrahlung cameras, and active shock breakout measurement of hohlraum temperature. The data acquisition system is capable of recording up to 500 channels and the data from each shot is available on the Internet. A major new diagnostic presently under construction is the BEAMLET backlighter. We will briefly describe each of these diagnostics and present some of the highest-quality data from them

  3. The Windows serial port programming handbook

    CERN Document Server

    Bai, Ying

    2004-01-01

    The fundamentals of serial port communications. Serial port programming in ANSI C and Assembly languages for MS-DOS. Serial ports interface developed in VC++ 6.0. Serial port programming in Visual Basic. Serial port programming in LabVIEW. Serial port programming in MATLAB. Serial port programming in Smalltalk. Serial port programming in Java.

  4. COSIMA-ES-PORT

    DEFF Research Database (Denmark)

    Barfod, Michael Bruhn; Leleur, Steen

    2007-01-01

    This article describes the results of the research project – WP3 East-west, Interreg IIIB – concerning the de¬velop¬ment of a new composite decision model, COSIMA-ES-PORT, for the assessment of three pre-feasibility studies situated at the Port of Esbjerg: a road project, a railway project...... and a multimodal terminal. The three studies indicates that a new road connection to the Port of Esbjerg is a very profitable project due to large travel time savings, whereas a new railway connection is not economically viable. However, a new multimodal terminal is also a very profitable project. The COSIMA...

  5. Revisiting port pricing : a proposal for seven port pricing principles

    NARCIS (Netherlands)

    Van Den Berg, R.; De Langen, P.W.; Van Zuijlen, P.C.J.

    2017-01-01

    A review of seven large landlord port authorities around the world reveals a notable diversity of pricing structures. While port authorities increasingly act as commercial undertakings, port pricing often seems to be not driven by commercial considerations. In this paper, we argue that ports can be

  6. Storage shaft definitive closure plug and method

    International Nuclear Information System (INIS)

    Dardaine, M.

    1992-01-01

    A definitive closure plug system for radioactive waste storage at any deepness, is presented. The inherent weight of the closure materials is used to set in the plug: these materials display an inclined sliding surface in such a way that when the closure material rests on a stable surface of the shaft storage materials, the relative sliding of the different materials tends to spread them towards the shaft internal wall so as to completely occlude the shaft

  7. PLUGGING AND UNPLUGGING OF WASTE TRANSFER PIPELINES

    International Nuclear Information System (INIS)

    Ebadian, M.A.

    1999-01-01

    This project, which began in FY97, involves both the flow loop research on plugging and unplugging of waste transfer pipelines, and the large-scale industrial equipment test of plugging locating and unplugging technologies. In FY98, the related work was performed under the project name ''Mixing, Settling, and Pipe Unplugging of Waste Transfer Lines.'' The mixing, settling, and pipeline plugging and unplugging are critical to the design and maintenance of a waste transfer pipeline system, especially for the High-Level Waste (HLW) pipeline transfer. The major objective of this work is to recreate pipeline plugging conditions for equipment testing of plug locating and removal and to provide systematic operating data for modification of equipment design and enhancement of performance of waste transfer lines used at DOE sites. As the waste tank clean-out and decommissioning program becomes active at the DOE sites, there is an increasing potential that the waste slurry transfer lines will become plugged and unable to transport waste slurry from one tank to another or from the mixing tank to processing facilities. Transfer systems may potentially become plugged if the solids concentration of the material being transferred increases beyond the capability of the prime mover or if upstream mixing is inadequately performed. Plugging can occur due to the solids' settling in either the mixing tank, the pumping system, or the transfer lines. In order to enhance and optimize the slurry's removal and transfer, refined and reliable data on the mixing, sampling, and pipe unplugging systems must be obtained based on both laboratory-scale and simulated in-situ operating conditions

  8. Plug-In Hybrid Electric Vehicle Basics | NREL

    Science.gov (United States)

    Plug-In Hybrid Electric Vehicle Basics Plug-In Hybrid Electric Vehicle Basics Imagine being able to one that's in a standard hybrid electric vehicle. The larger battery pack allows plug-in hybrids to between fill-ups) that's very similar to the range of a conventional vehicle. A plug-in hybrid vehicle's

  9. Oluvil Port Development Project

    DEFF Research Database (Denmark)

    Frigaard, Peter; Margheritini, Lucia

    Oluvil Port Development Project is the first development of a large port infrastructure in the entire eastern coastline of Sri Lanka. The project is supported by the Danish Foreign Ministry. Feasibility studies and detailed design studies were carried out by Lanka Hydraulic Institute Ltd during...... the years 1995 to 2003. The design was reviewed by COWI a/s. Construction of the port was started in 2008. MT Højgaard a/s acted as contractor. The outer breakwaters were constructed as first part of the project. During and after completion of the breakwaters a serious beach erosion and sand accumulation...... has been observed. Severe erosion is seen north of the harbour and some accumulation of sand is seen south of the harbour. On a sandy coastline like the one in Oluvil such erosion problems as observed are very typical. The report: Oluvil Port Development Project: Studies on Beach Erosion written...

  10. Slewing Port Jib Cranes

    OpenAIRE

    Boris Visočnik; Stojan Kravanja

    2002-01-01

    The paper presents slewing port cranes with a luffing jib. The advantages of slewing port jib cranes are high lifting capacities, high speeds of re-loading and excellent mobility since they are capable of load lifting, travelling, luffing and slewing. The paper gives a detailed description of their characteristics such as the highest reached load-carrying capacities, speeds of motion and accelerations. It also presents the crane assembly, driving mechanisms, loads and load cases, transport by...

  11. Test plan: Potash Core Test. WIPP experimental program borehole plugging

    International Nuclear Information System (INIS)

    Christensen, C.L.

    1979-09-01

    The Potash Core Test will utilize a WIPP emplaced plug to obtain samples of an in-situ cured plug of known mix constituents for bench scale testing. An earlier effort involved recovery at the salt horizon of Plug 217, a 17 year old plug in a potash exploration hole for bond testing, but the lack of particulars in the emplacement precluded significant determination of plug performance

  12. Engineering design of the ITER Collective Thomson Scattering diagnostic. Contract EFDA 06-1478

    International Nuclear Information System (INIS)

    Michelsen, P.K.; Furtula, V.; Korsholm, S.B.; Leipold, F.; Meo, F.; Salewski, M.; Bindslev, H.; Lauritzen, B.; Lucas, M.; Nonboel, E.

    2009-12-01

    This report describes the work done under EFDA contract 06-1478 (EFDA Ref.: TW6-TPDS-DIASUP10). The main part of the work has been focused on: 1) An outline plan for the full development of the CTS diagnostic for ITER, including specifications for future design tasks on the system and R and D tasks on critical components. 2) An engineering design and test in a blanket mock-up of the frontend quasi-optical High Field Side (HFS) antenna system,. 3) Some considerations on the waveguide mounting. 4) Neutronics and thermo-elastic calculations on nuclear and radiative heating of the first mirror required to provide input to the engineering design. 5) An engineering design of the front-end quasi-optical components for the Low Field Side (LFS) system in the port plug. 6) A discussion on possible calibration methods. (author)

  13. Integration of ITER in-vessel diagnostic components in the vacuum vessel

    International Nuclear Information System (INIS)

    Encheva, A.; Bertalot, L.; Macklin, B.; Vayakis, G.; Walker, C.

    2009-01-01

    The integration of ITER in-vessel diagnostic components is an important engineering activity. The positioning of the diagnostic components must correlate not only with their functional specifications but also with the design of the major parts of ITER torus, in particular the vacuum vessel, blanket modules, blanket manifolds, divertor, and port plugs, some of which are not yet finally designed. Moreover, the recently introduced Edge Localised Mode (ELM)/Vertical Stability (VS) coils mounted on the vacuum vessel inner wall call for not only more than a simple review of the engineering design settled down for several years now, but also for a change in the in-vessel distribution of the diagnostic components and their full impact has yet to be determined. Meanwhile, the procurement arrangement (a document defining roles and responsibilities of ITER Organization and Domestic Agency(s) (DAs) for each in-kind procurement including technical scope of work, quality assurance requirements, schedule, administrative matters) for the vacuum vessel must be finalized. These make the interface process even more challenging in terms of meeting the vacuum vessel (VV) procurement arrangement's deadline. The process of planning the installation of all the ITER diagnostics and integrating their installation into the ITER Integrated Project Schedule (IPS) is now underway. This paper covers the progress made recently on updating and issuing the interfaces of the in-vessel diagnostic components with the vacuum vessel, outlines the requirements for their attachment and summarises the installation sequence.

  14. Diagnostics vehicle’s condition using obd-ii and raspberry pi technology: study literature

    Science.gov (United States)

    Moniaga, J. V.; Manalu, S. R.; Hadipurnawan, D. A.; Sahidi, F.

    2018-03-01

    Transportation accident rate are still being a major challenge in many countries. There are many factors that could be cause transportation accident, especially in vehicle’s internal system problem. To overcome this problem, OBD-II technology has been created to diagnostics vehicle’s condition. OBD-II scanner plugged to OBD-II port or usually called Data Link Connector (DLC), and after that it sends the diagnostics to Raspberry Pi. Compared from another microcontrollers, Arduino, Raspberry Pi are chosen because it sustains the application to receive real-time diagnostics, process the diagnostics and send command to automobiles at the same time, rather than Arduino that must wait for another process finished to run another process. Outcome from this application is to enable automobile’s user to diagnostics their own vehicles. If there is found something unusual or a problem, the application can told the problem to user, so they could know what to fix before they use their vehicle safely.

  15. Slewing Port Jib Cranes

    Directory of Open Access Journals (Sweden)

    Boris Visočnik

    2002-09-01

    Full Text Available The paper presents slewing port cra11es with a luffing jib.The advantages of slewing port jib cranes are high lifting capacities,high speeds of re-loading and excellent mobility since theyare capable of load lifting, travelling, luffing and slewing. Thepaper gives a detailed description of their characteristics suchas the highest reached load-canying capacities, speeds of motionand accelerations. It also presents the crane assembly,driving mechanisms, loads and load cases, transport by shipsand testing of lifting capacity. As a practical example the paperpresents the slewing port jib crane with the capacity of25!15!5 tat a 27/37/40 m radius made by the Slovenian companyMetalna Maribor for the shipyard 3. Maj, Rijeka, Croatia.

  16. HomePort

    DEFF Research Database (Denmark)

    Le Guilly, Thibaut; Olsen, Petur; Ravn, Anders Peter

    2013-01-01

    Ambient Intelligence systems use many sensors and actuators, with a diversity of networks, protocols and technologies which makes it impossible to access the devices in a common manner. This paper presents the HomePort software, which provides an open source RESTful interface to heterogeneous...... sensor networks, allowing a simple unified access to virtually any kind of protocol using well known standards. HomePort includes means to provide event notification, as well as a tracing mechanism. The software is implemented and we report on initial experiments and provide an evaluation that shows...

  17. Port entry arrangements

    International Nuclear Information System (INIS)

    Chicken, J.C.; King, M.A.

    1978-01-01

    The objective of the paper is to describe the safety scheme port authorities should establish to deal with any contingency that may result from the visit of a nuclear powered ship. The safety scheme should be devised to cover both normal operation and any accident conditions that could arise while the ship is in port. The paper is divided into three parts. The three parts being: background information, general instructions, and emergency procedures. The background information will describe the nature of the hazards a port authority has to be prepared to deal with, and the philosophical basis for a berthing policy. In the part dealing with general instructions the objective of the safety scheme will be described. Also this part will describe the composition of the Port Safety Panel, allocation of responsibilities, passage and berthing arrangements, general safety precautions, records required, and rescue arrangements. In the part dealing with emergency procedures the role of: the Ship's Master, Harbour Authorities, Local Police, and local Health Services are discussed. As an Appendix to the paper a copy of the safety scheme that has been devised for visits of nuclear merchant ships to Southampton is given

  18. Strategic port development

    DEFF Research Database (Denmark)

    Olesen, Peter Bjerg; Dukovska-Popovska, Iskra; Steger-Jensen, Kenn

    2012-01-01

    This paper proposes a framework for strategic development of a port’s collaboration with its hinterland. The framework is based on literature relevant to port development and undertakes market perspective by considering import/export data relevant for the region of interest. The series of steps...

  19. Ports and innovation

    NARCIS (Netherlands)

    Taneja, P.; Vellinga, T.; Van Schuylenburg, M.

    2012-01-01

    A volatile environment, dynamic markets, and challenges created by new environmental and social consideration demand innovative solutions. Innovation is the implementation of ideas to create value. It promises ports resilience into the future. In this paper we trace some recent successful

  20. Essays on Dry Ports

    NARCIS (Netherlands)

    G.G. Chandrakant (Gujar)

    2011-01-01

    textabstractDue to several reasons, currently the global supply chains are getting stretched further away into the hinterlands from the gateway seaports. This single fact enhances the importance of dry ports. It would not be against logic, to state that in coming times, as a result of ever-growing

  1. Port-wine stain

    Science.gov (United States)

    ... About MedlinePlus Show Search Search MedlinePlus GO GO About MedlinePlus Site Map FAQs Customer Support Health Topics Drugs & Supplements Videos & Tools Español You Are Here: Home → Medical Encyclopedia → Port-wine stain URL of this page: //medlineplus.gov/ency/ ...

  2. Downhole television (DHTV) applications in borehole plugging

    International Nuclear Information System (INIS)

    Christensen, C.L.; Statler, R.D.; Peterson, E.W.

    1980-05-01

    The Borehole Plugging (BHP) Program is a part of the Sandia experimental program to support the Waste Isolation Pilot Plant (WIPP). The Sandia BHP program is an Office of Nuclear Waste Isolation (ONWI)-funded program designed to provide inputs to the generic plugging program while simultaneously acquiring WIPP-specific data. For this reason a close liaison is maintained between the Sandia WIPP project and the ONWI generic program. Useful technology developed within the Sandia BHP to support WIPP is made available and considered for further development and application to the generic Borehole Plugging and Repository Sealing Program at ONWI. The purpose of this report is to illustrate the usefulness of downhole television (DHTV) observations of a borehole to plan plugging operations. An indication of the wellbore conditions observed is provided. The equipment and setup procedure used in the evaluation of AEC-7 for the Bell Canyon test series are illustrated. A sequence of pictures at various depths as the DHTV rig is lowered through the wellbore is presented. Sample photographs taken with both dry and underwater lamps for illumination are included. The caliper logs for the same depth are included for comparison. General comments are provided on the illustrations

  3. FY-1979 progress report. Hydrotransport plugging study.

    Energy Technology Data Exchange (ETDEWEB)

    Eyler, L.L.; Lombardo, N.J.

    1980-01-01

    The objective of the Hydrotransport Plugging Study is to investigate phenomena associated with predicting the onset and occurrence of plugging in pipeline transport of coal. This study addresses large particle transport plugging phenomena that may be encountered in run-of-mine operations. The project is being conducted in four tasks: review and analysis of current capabilities and available data, analytical modeling, experimental investigations, and unplugging and static start-up. This report documents work completed in FY-1979 as well as work currently in progress. A review of currently available prediction methods was completed. Applicability of the methods to large particle hydrotransport and the prediction of plugging was evaluated. It was determined that available models were inadequate, either because they are empirical and tuned to a given solid or because they are simplified analytical models incapable of accounting for a wide range of parameters. Complicated regression curve fit models lacking a physical basis cannot be extrapolated with confidence. Several specific conclusions were reached: Recent developments in mechanistic modeling, describing flow conditions at the limit of stationary deposition, provide the best basis for prediction and extrapolation of large particle flow. Certain modeled phenomena require further analytical and experimental investigation to improve confidence levels. Experimental work needs to be performed to support modeling and to provide an adequate data base for comparison purposes. No available model permits treatment of solids mixtures such as coal and rock.

  4. An Overview of the HomePlug AV2 Technology

    Directory of Open Access Journals (Sweden)

    Larry Yonge

    2013-01-01

    Full Text Available HomePlug AV2 is the solution identified by the HomePlug Alliance to achieve the improved data rate performance required by the new generation of multimedia applications without the need to install extra wires. Developed by industry-leading participants in the HomePlug AV Technical Working Group, the HomePlug AV2 technology provides Gigabit-class connection speeds over the existing AC wires within home. It is designed to meet the market demands for the full set of future in-home networking connectivity. Moreover, HomePlug AV2 guarantees backward interoperability with other HomePlug systems. In this paper, the HomePlug AV2 system architecture is introduced and the technical details of the key features at both the PHY and MAC layers are described. The HomePlug AV2 performance is assessed, through simulations reproducing real home scenarios.

  5. Plug-in hybrid electric vehicle R&D plan

    Energy Technology Data Exchange (ETDEWEB)

    None, None

    2007-06-01

    FCVT, in consultation with industry and other appropriate DOE offices, developed the Draft Plug-In Hybrid Electric Vehicle R&D Plan to accelerate the development and deployment of technologies critical for plug-in hybrid vehicles.

  6. An optimal design for millimeter-wide facture plugging zone

    Directory of Open Access Journals (Sweden)

    Yili Kang

    2015-01-01

    Full Text Available Lost circulation control in millimeter-wide fractures has been a challenge in well drilling all the time. Low pressure-bearing capacity of a plugging zone will result in excessive consumption of lost circulation materials (LCMs and extra down time. In this study, laboratory experiments were conducted on the plugging of millimeter-wide fractures to evaluate the plugging effects of different types of LCM including rigid granules, elastic particles and fiber. Maximum plugging pressure, total loss volume before sealing and plugging time were taken as the evaluation index of the LCM plugging effect. According to the experimental results, the synergistic plugging mechanisms of different LCM combinations were also analyzed. Experimental results showed that the total loss volume of the plugging zone formed by rigid and elastic particle combination was generally greater than 400 mL, and the maximum plugging pressure of the plugging zone formed by elastic particle and fiber combination was generally less than 6 MPa. In contrast, the plugging zone formed by the combination of the three types of LCMs has the maximum plugging pressure of up to 13 MPa and total loss volume before sealing of 75 mL. In the synergistic plugging process, rigid granules form a frame with high pressure-bearing capacity in the narrower parts of the fractures; elastic particles generate elastic force through elastic deformation to increase the friction between a fracture and a plugging zone to make the plugging zone more stable; fibers filling in the pore space between the particles increase the tightness and integrity of the plugging zone. The experimental results can provide guidance for the optimal design of LCMs used in the field.

  7. Bond strength of cementitious borehole plugs in welded tuff

    International Nuclear Information System (INIS)

    Akgun, H.; Daemen, J.J.K.

    1991-02-01

    Axial loads on plugs or seals in an underground repository due to gas, water pressures and temperature changes induced subsequent to waste and plug emplacement lead to shear stresses at the plug/rock contact. Therefore, the bond between the plug and rock is a critical element for the design and effectiveness of plugs in boreholes, shafts or tunnels. This study includes a systematic investigation of the bond strength of cementitious borehole plugs in welded tuff. Analytical and numerical analysis of borehole plug-rock stress transfer mechanics is performed. The interface strength and deformation are studied as a function of Young's modulus ratio of plug and rock, plug length and rock cylinder outside-to-inside radius ratio. The tensile stresses in and near an axially loaded plug are analyzed. The frictional interface strength of an axially loaded borehole plug, the effect of axial stress and lateral external stress, and thermal effects are also analyzed. Implications for plug design are discussed. The main conclusion is a strong recommendation to design friction plugs in shafts, drifts, tunnels or boreholes with a minimum length to diameter ratio of four. Such a geometrical design will reduce tensile stresses in the plug and in the host rock to a level which should minimize the risk of long-term deterioration caused by excessive tensile stresses. Push-out tests have been used to determine the bond strength by applying an axial load to cement plugs emplaced in boreholes in welded tuff cylinders. A total of 130 push-out tests have been performed as a function of borehole size, plug length, temperature, and degree of saturation of the host tuff. The use of four different borehole radii enables evaluation of size effects. 119 refs., 42 figs., 20 tabs

  8. Plug-In Hybrid Urban Delivery Truck Technology Demonstration

    Energy Technology Data Exchange (ETDEWEB)

    Miyasato, Matt [South Coast Air Quality Management District Building Corporation, Diamond Bar, CA (United States); Impllitti, Joseph [South Coast Air Quality Management District Building Corporation, Diamond Bar, CA (United States); Pascal, Amar [South Coast Air Quality Management District Building Corporation, Diamond Bar, CA (United States)

    2015-07-31

    The I-710 and CA-60 highways are key transportation corridors in the Southern California region that are heavily used on a daily basis by heavy duty drayage trucks that transport the cargo from the ports to the inland transportation terminals. These terminals, which include store/warehouses, inland-railways, are anywhere from 5 to 50 miles in distance from the ports. The concentrated operation of these drayage vehicles in these corridors has had and will continue to have a significant impact on the air quality in this region whereby significantly impacting the quality of life in the communities surrounding these corridors. To reduce these negative impacts it is critical that zero and near-zero emission technologies be developed and deployed in the region. A potential local market size of up to 46,000 trucks exists in the South Coast Air Basin, based on near- dock drayage trucks and trucks operating on the I-710 freeway. The South Coast Air Quality Management District (SCAQMD), California Air Resources Board (CARB) and Southern California Association of Governments (SCAG) — the agencies responsible for preparing the State Implementation Plan required under the federal Clean Air Act — have stated that to attain federal air quality standards the region will need to transition to broad use of zero and near zero emission energy sources in cars, trucks and other equipment (Southern California Association of Governments et al, 2011). SCAQMD partnered with Volvo Trucks to develop, build and demonstrate a prototype Class 8 heavy-duty plug-in hybrid drayage truck with significantly reduced emissions and fuel use. Volvo’s approach leveraged the group’s global knowledge and experience in designing and deploying electromobility products. The proprietary hybrid driveline selected for this proof of concept was integrated with multiple enhancements to the complete vehicle in order to maximize the emission and energy impact of electrification. A detailed review of all

  9. Update on the status of the ITER ECE diagnostic design

    Directory of Open Access Journals (Sweden)

    Taylor G.

    2017-01-01

    Full Text Available Considerable progress has been made on the design of the ITER electron cyclotron emission (ECE diagnostic over the past two years. Radial and oblique views are still included in the design in order to measure distortions in the electron momentum distribution, but the oblique view has been redirected to reduce stray millimeter radiation from the electron cyclotron heating system. A major challenge has been designing the 1000 K calibration sources and remotely activated mirrors located in the ECE diagnostic shield module (DSM in the equatorial port plug #09. These critical systems are being modeled and prototypes are being developed. Providing adequate neutron shielding in the DSM while allowing sufficient space for optical components is also a significant challenge. Four 45-meter long low-loss transmission lines transport the 70–1000 GHz ECE from the DSM to the ECE instrumentation room. Prototype transmission lines are being tested, as are the polarization splitter modules that separate O-mode and X-mode polarized ECE. A highly integrated prototype 200–300 GHz radiometer is being tested on the DIII-D tokamak in the USA. Design activities also include integration of ECE signals into the ITER plasma control system and determining the hardware and software architecture needed to control and calibrate the ECE instruments.

  10. Green Port / Eco Port Project - Applications and Procedures in Turkey

    Science.gov (United States)

    Akgul, Burak

    2017-12-01

    As being the heartlands of international trade, sea ports are the junction points of land and sea routes. The growth of global trade has led to the development of number and capacity as well as the service quality of ports. The policies and procedures applied during construction, operation and development of ports under development with environmental considerations scope has evolved in accordance with the needs of global trends. Although maritime transportation provides the most ecofriendly transportation method, the reduction of potential environmental threats and continuous improvement of ports and their vicinity is paramount from environmental concerns with regards to the international environmental standards. In the context of the study, national and international legal regulations governing the control of the environmental impacts of the activity groups causing pollution in Turkey based sea ports were viewed. In addition, the models applied during the measurement and documentation of environmental impacts were investigated. The most important aspects in terms of the effectiveness of the environmental management models are legal regulations. However, the standards applied at the ports without any legal obligation, such as EcoPorts applications, ISO 14001 standard, and the EMAS (Eco-Management and Audit Scheme) were sought in the scope of the study. The boundaries of the study were determined as the EU based Environmental Management Systems and the Green Port/Eco Port Project which is being administered by the Turkish Ministry of Transport, Maritime and Communication. “Marport”, which is Turkey’s first certified Green Port / Eco Port is designated as the experimental study site. In addition, the provisions in the ports of ESPO member countries are approached in order to compare the effectiveness and applicability of Green Port / Eco Port Project.

  11. Port Card Module

    International Nuclear Information System (INIS)

    Utes, M.

    1994-01-01

    The Port Card will be one link in the data acquisition system for the D0 Silicon Vertex Detector. This system consists of the following parts, starting at the detector: Silicon strip detectors are mounted in a spaceframe and wire-bonded to custom bare-die integrated circuits (SVX-II chips) that digitize the charge collected by the strips. The 128-channel chips are mounted on a High-Density Interconnect (HDI) that consists of a small flex circuit that routes control signals and eight data bits for each of three to ten chips onto a common data bus. A cable then routes this bus approximately thirty feet out from the detector to the Port Card. The Port Card houses a commercial chipset that serializes the data in real time and converts the signal into laser light impulses that are then transmitted through a multi-mode optical fiber about 150 feet to a Silicon Acquisition and Readout board (SAR). Here, the data is transformed back to parallel electrical signals that are stored in one of several banks of FIFO memories. The FIFOs place their data onto the VME backplane to a VME Buffer Driver (VBD) which stores the event data in buffers for eventual readout over a thirty-two signal ribbon cable to the Level Two Computers and subsequent tape storage. Control and sequencing of the whole operation starts with the Silicon Acquisition/Readout Controller (SARC) working in tandem with the D0 Clock System. The SARC resides in the same VME crate as the SARs, and transforms signals from the Trigger System into control codes distributed to the various Port Cards via optical fibers operating at 53 Mb/s. It is through these control codes that data taking operations such as data-acquisition, digitization, readout, and various resets can be carried out. The Port Card receives the control codes and manipulates the SVX-II chips in the proper way to effect proper data taking. There will be a total of about 700,000 channels, which translates into about 5580 SVX-II chips, 66 to 100 Port Cards

  12. Effects of noise-induced hearing loss within Port Harcourt metropolis ...

    African Journals Online (AJOL)

    This paper investigates the effects of Noise-Induced Hearing Loss within Port Harcourt Metropolis using a micro-controlled diagnostic audiometer (Kamplex KLD21).The data was obtained at two specific locations namely: Rivers State University of Science and Technology and Port Harcourt International Airport.

  13. Installation of the backfill and plug test

    International Nuclear Information System (INIS)

    Gunnarsson, D.; Borgesson, L.; Hokmark, H.; Hohannesson, L.E.; Sanden, T.

    2003-01-01

    The Backfill and Plug Test is a full scale test of backfill material, backfilling technique and a tunnel plug. The main objectives of the Backfill and Plug Test are: - to develop and test different materials and compaction techniques for backfilling of tunnels excavated by blasting; - to test the function of the backfill and its interaction with the surrounding rock in a tunnel excavated by blasting; - to develop technique for building tunnel plugs and to test the function. The installation was made in the Swedish underground laboratory, Aspo HRL, during 1999. The inner part of the tunnel is not used for the test but was filled with drainage material. The test volume, which is about 28 m long, can be divided into the following three parts: - the inner part filled with backfill containing 30% bentonite; - the outer part filled with backfill without bentonite and bentonite blocks and pellets at the roof; - the plug. Permeable layers divide the test volume into 11 test sections. The permeable layers are used for increasing the water saturation rate in the backfill and for applying hydraulic gradients between the layers for studying the flow of water in the backfill and in the near field rock. The permeable layers were installed every 2.2 m and each layer is divided into three units in order to separately measure the flow close to the roof, in the central areas of the tunnel and close to the floor. The outer part ends with a wall of prefabricated concrete beams that were used for temporary support of the backfill during the casting of the plug. The upper volume close to the plug is filled with bentonite pellets and blocks consisting of 20% bentonite and 80% sand. The backfill is instrumented with 34 pore water pressure cells, 21 total pressure cells, 57 sensors for monitoring the water saturation and 13 gauges for measuring the local hydraulic conductivity. The water pressures in the permeable mats are measured in all sections. Four pressure cylinders, 2 in the roof

  14. HomePort

    DEFF Research Database (Denmark)

    Madsen, Per Printz

    2009-01-01

    In the last couple of year's computer based home control systems are getting more and more common in modern homes. For instance these systems take care of light control, heat control and security systems.  The latest trend is to use wireless communication like Z-Wave and ZigBee to interconnect...... different components in these systems. One of the characteristics is that each system, like for instance heat and light, has their own specific way of using the communication system.   This paper describes a way to connect different home control systems through an intelligent gateway, called a Home......Port. The HomePort consists of a number of Subsystem communication drivers, a virtual communication layer, an interpreter and a PC- based compiler for a high level control language, called GIL (Gateway intelligence language). The focus in this paper will be on the upper two layers in the Home...

  15. Port interface requirements

    International Nuclear Information System (INIS)

    O'Neil, R.

    1978-01-01

    In a land-based reactor programme the Administration are usually confronted with a specific design in a particular environment. Safety and Reliability criteria necessary to the designer can be specified on the basis of acceptable risk to the population. However for the successful implementation of a nuclear ship programme on a broad commercial basis it is necessary to have agreed standards of risks from ships yet to be designed and agreed standards of acceptable risks to the population at likely ports of call yet to be specified, consulted, or agreed. At first sight it would seem that this double uncertainty must either lead to unnecessarily high safety standards for the ship or unacceptably conservative standards for berth selection. The paper discusses the problem and proposes a possible solution based on the concept of a 'Standard Port' and a 'Standard Ship' and indicates the level of risk implied by such a concept

  16. Recent developments in plugging of steam generator tubes

    International Nuclear Information System (INIS)

    Buhay, S.; Abucay, R.C.

    1995-01-01

    Mechanical Plugging capability has been developed for Bruce Nuclear Generating Station (BNGS) steam generator (SG) tubes and Darlington Nuclear Generating Station (DNGS) SG tubes and tubesheet holes. The plug concept was a modified ABB/Combustion Engineering Inconel 690 plug with a nickel band, rolled into the tube or tubesheet hole from the primary side of the tubesheet. The qualification program included analytical justification of the plug body and experimental testing to verify the leak tightness of the rolled joint under conditions which meet or exceed all service or design requirements. Tools and procedures were developed and tested for manual and remote/robotic installation and removal of the mechanical plugs. Additionally, tools and procedures were developed to plug tubes/tubesheet holes at DNGS in the event the steam generator is recalled to service to act as a heat sink. A crew of Ontario Hydro personnel were trained and qualified for the installation of mechanical plugs for permanent and recall applications. During the DNGS Unit 4 spring 1995 outage, 6 tubes were plugged and the 'Recall Plugging Capability' was deployed and ready for use during a primary side SG tube removal. The mechanical plugs were installed manually with a typical 3 minute/plug in-bowl duration time with an average radiation dose of 12.5 mrem per plug. This compares favourably with manual plug welding during the same outage in the same SG bowl at approximately 15-30 minutes/plug in-bowl duration with an average radiation dose of 117 mrem/plug. (author)

  17. Plugging of feed inlet tube upstands with Ni/Ti shape memory alloy plugs - Heysham 1 power station

    International Nuclear Information System (INIS)

    Mathews, A.J.

    1988-01-01

    The paper contains a description of a new approach for Plugging feed inlet tubes of Gas-Cooled Reactors. Instead of utilizing the original explosive method plugging by fitting a shape memory alloy plug into the upstand is being described. (author)

  18. Industry perspectives on Plug-& -Play Spacecraft Avionics

    Science.gov (United States)

    Franck, R.; Graven, P.; Liptak, L.

    This paper describes the methodologies and findings from an industry survey of awareness and utility of Spacecraft Plug-& -Play Avionics (SPA). The survey was conducted via interviews, in-person and teleconference, with spacecraft prime contractors and suppliers. It focuses primarily on AFRL's SPA technology development activities but also explores the broader applicability and utility of Plug-& -Play (PnP) architectures for spacecraft. Interviews include large and small suppliers as well as large and small spacecraft prime contractors. Through these “ product marketing” interviews, awareness and attitudes can be assessed, key technical and market barriers can be identified, and opportunities for improvement can be uncovered. Although this effort focuses on a high-level assessment, similar processes can be used to develop business cases and economic models which may be necessary to support investment decisions.

  19. CDF End Plug calorimeter Upgrade Project

    International Nuclear Information System (INIS)

    Apollinari, G.; de Barbaro, P.; Mishina, M.

    1994-01-01

    We report on the status of the CDF End Plug Upgrade Project. In this project, the CDF calorimeters in the end plug and the forward regions will be replaced by a single scintillator based calorimeter. After an extensive R ampersand D effort on the tile/fiber calorimetry, we have now advanced to a construction phase. We review the results of the R ampersand D leading to the final design of the calorimeters and the development of tooling devised for this project. The quality control program of the production of the electromagnetic and hadronic calorimeters is described. A shower maximum detector for the measurement of the shower centroid and the shower profile of electrons, γ and π 0 has been designed. Its performance requirements, R ampersand D results and mechanical design are discussed

  20. Maintenance implications of critical components in ITER CXRS upper port plug design

    NARCIS (Netherlands)

    Koning, J.; Jaspers, R.; Doornink, J.; Ouwehand, B.; Klinkhamer, J.F.F.; Snijders, B.; Sadakov, S.; Heemskerk, C.

    2009-01-01

    Already in the early phase of a design for ITER, the maintenance aspects should be taken into account, since they might have serious implications. This paper presents the arguments in support of the case for the maintainability of the design, notably if this maintenance is to be performed by

  1. Cost estimate for electrostatically plugged cusp reactor

    International Nuclear Information System (INIS)

    Dolan, T.J.

    1977-01-01

    A preliminary design of an electrostatically plugged cusp reactor was presented in (UCRL-52142(1976)). The capital costs of the various components of this reactor are estimated and totaled for two different blanket configurations: one having an energy multiplication factor M = 1.2, and the other having M = 1.68. The unoptimized direct capital costs for these cases are found to be about 1400 and 950 $/kWe, respectively

  2. Borehole plugging by hydrothermal transport. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Roy, D.M.; White, W.B.

    1976-02-28

    Calcium silicate--and aluminosilicate--compositions based on mixtures of fine grained quartz with various cements or calcium silicate compounds have been investigated under hydrothermal conditions in the temperature range 110-250/sup 0/C and pressure range 1,000-10,000 psi, pressures which are always in excess of that required to maintain liquid H/sub 2/O, and approximate the confining pressures which might be anticipated in deep boreholes. All silicate cement combinations investigated produce materials having adequate strength after reaction times of 1 day or longer. The calcium aluminate cement was also adequate with respect to strength but would need to be investigated more extensively for overall properties because of its highly reactive chemistry. The mini-rock cylinder-cement plug hydrothermal experiments in both limestone and sandstone resulted in reasonable magnitudes of bonding strength. The typical shear strength of a hydrothermally treated cement-sandstone plug is 1030 psi, and the compressive strength of the extruded cement plug is 9550 psi. Reactions having a potential for producing calcium carbonate plugs in holes drilled in carbonate rocks were studied. It should be noted that most cements are calcium silicate systems and are chemically compatible with the CaCO/sub 3/ and CaMg(CO/sub 3/)/sub 2/ in the rock walls of the hole. A side benefit from this research is some insight into the suitability of massive carbonate rocks as disposal sites. Carbonate rocks by themselves are highly impermeable, have low exchange capacity, and a low water content--all properties that are desirable in the storage medium. A major drawback is the presence of secondary permeability in the form of solutionally modified joints, fractures, and bedding planes.

  3. Borehole plugging by hydrothermal transport. Final report

    International Nuclear Information System (INIS)

    Roy, D.M.; White, W.B.

    1976-01-01

    Calcium silicate--and aluminosilicate--compositions based on mixtures of fine grained quartz with various cements or calcium silicate compounds have been investigated under hydrothermal conditions in the temperature range 110-250 0 C and pressure range 1,000-10,000 psi, pressures which are always in excess of that required to maintain liquid H 2 O, and approximate the confining pressures which might be anticipated in deep boreholes. All silicate cement combinations investigated produce materials having adequate strength after reaction times of 1 day or longer. The calcium aluminate cement was also adequate with respect to strength but would need to be investigated more extensively for overall properties because of its highly reactive chemistry. The mini-rock cylinder-cement plug hydrothermal experiments in both limestone and sandstone resulted in reasonable magnitudes of bonding strength. The typical shear strength of a hydrothermally treated cement-sandstone plug is 1030 psi, and the compressive strength of the extruded cement plug is 9550 psi. Reactions having a potential for producing calcium carbonate plugs in holes drilled in carbonate rocks were studied. It should be noted that most cements are calcium silicate systems and are chemically compatible with the CaCO 3 and CaMg(CO 3 ) 2 in the rock walls of the hole. A side benefit from this research is some insight into the suitability of massive carbonate rocks as disposal sites. Carbonate rocks by themselves are highly impermeable, have low exchange capacity, and a low water content--all properties that are desirable in the storage medium. A major drawback is the presence of secondary permeability in the form of solutionally modified joints, fractures, and bedding planes

  4. Plug and abandonment operations and tool positioning

    OpenAIRE

    Saad, Idrees

    2014-01-01

    Master's thesis in Petroleum engineering With aging oil fields, the Norwegian petroleum authorities are focusing on Plug and Abandonment (P&A) plans. Therefore efforts are being made, by relevant authorities, to improve standards and procedures for the P&A operations. Regulations for UK part of the North Sea define the P&A operation plans and execution phases in a way that may help improve the standards on the Norwegian Continental Shelf. Halliburton like its competitors is focusing on ...

  5. Development of simplified rotating plug seal structure

    International Nuclear Information System (INIS)

    Ueta, M.; Ichimiya, M.; Kanaoka, T.; Sekiya, H.; Ueda, S.; Ishibashi, S.

    1991-01-01

    We studied a compact and simplified rotating plug seal structure and conducted experiments for key elements of the concept such us the mechanical seal structure and sodium deposit prevention system. Good characteristics were confirmed for the mechanical seal structure, which utilizes an elastomer seal and thin lathe bearing. Applicability of the density barrier concept was also confirmed as the sodium deposit prevention system. This concept can be applied to actual plants. (author)

  6. Ice plugging of pipes using liquid nitrogen

    International Nuclear Information System (INIS)

    Twigg, R.J.

    1987-03-01

    This report presents a study on the ice plugging of pipe using liquid nitrogen, and is based on a literature review and on discussions with individuals who use the technique. Emphasis is placed on ferritic alloys, primarily carbon steels, in pipe sized up to 60 cm in diameter and on austenitic stainless steels in pipe sizes up to 30 cm in diameter. This technique is frequently used for leak testing in nuclear facilities

  7. Borehole Plugging-Materials Development Program

    International Nuclear Information System (INIS)

    Gulick, C.W. Jr.

    1978-06-01

    This report discusses the background and first year's results of the grouting materials development program for plugging boreholes associated with the Nuclear Waste Isolation Pilot Plant. The grouts are to be pumpable, impermeable, and durable for many thousands of years. The work was done at the Concrete Laboratory of the U.S. Army Engineer Waterways Experiment Station (WES), Vicksburg, Mississippi. The workability, strength, porosity, bonding, expansion, and permeability data are summarized and discussed. The work is continuing at WES

  8. Handling of waste in ports

    International Nuclear Information System (INIS)

    Olson, P.H.

    1994-01-01

    The regulations governing the handling of port-generated waste are often national and/or local legislation, whereas the handling of ship-generated waste is governed by the MARPOL Convention in most parts of the world. The handling of waste consists of two main phases -collection and treatment. Waste has to be collected in every port and on board every ship, whereas generally only some wastes are treated and to a certain degree in ports and on board ships. This paper considers the different kinds of waste generated in both ports and on board ships, where and how it is generated, how it could be collected and treated. The two sources are treated together to show how some ship-generated waste may be treated in port installations primarily constructed for the treatment of the port-generated waste, making integrated use of the available treatment facilities. (author)

  9. Mechanism of Randall’s Plugs Development

    Directory of Open Access Journals (Sweden)

    Felix Grases

    2017-09-01

    Full Text Available Mechanism of formation and development of intraluminal concretion, also called Randall's plug, extracted from a female patient forming calcium oxalate dihydrate (COD calculi was examined. Some of these calculi were connected to the papillary tip, and had connections with the interior of the papilla with finger-like extensions in the collecting duct (CD. The intraluminal concretion consisted of inter-grown COD crystals of irregular size (30–100 μm, approximately 5% of biological hydroxyapatite (BHAP and an organic matter. Urine of the patient was moderately supersaturated with respect to COD and amorphous calcium phosphate (ACP. Model of kidney, recently refined by Robertson, was used in calculations. Calculated Reynolds number indicated that the flow of liquid through tubules was purely laminar with parabolic velocity profile. COD crystals formed at the beginning of ascending loop of Henle by heterogeneous nucleation. Concentration of COD crystals in urine was limited and considered equal to concentration of crystals during crystaluria. The free particle and the fixed particle mechanisms were considered. The free particle mechanism assumes formation of a single crystal or agglomerate of crystals blocking the CD by virtue of size. The growth of COD crystals at concrete urinary supersaturation was too slow for a single crystal to attain size with settling velocity faster than the translation flow rate of liquid. Hydrodynamic shear caused aggregation of COD solid particles dispersed in a liquid flowing in the nephron. Number of COD crystals present in urine was not sufficient for formation of fractal agglomerate blocking the Bellini duct. Similarly, a fractal agglomerate of urinary phosphate present in the form of Posner's clusters was not large enough to obstruct the Bellini duct. The opening of the CD could not be obstructed by a single crystal of COD or fractal agglomerate composed of either COD crystals or calcium phosphate clusters, formed

  10. A review of dry ports

    OpenAIRE

    Violeta Roso; Kent Lumsden

    2010-01-01

    The objective of this article is to present the previous research on the dry port concept and to review the world's existing dry ports, that is freight terminals that use the term ‘dry port’ in their name. Therefore, the purpose of this article is to clarify the concept by showing potential discrepancies or agreements between theory and practice. Starting from a literature review on the dry port concept, this article presents a review of existing dry ports in the world. A number of qualitativ...

  11. DIII-D in-vessel port cover and shutter assembly for the phase contrast interferometer

    International Nuclear Information System (INIS)

    Phelps, R.D.

    1994-01-01

    The entire outer wall of the DIII-D vacuum vessel interion is covered with a regular array of graphite tiles. Certain of the diagnostic ports through the outer vessel wall contain equipment which is shielded from the plasma by installing port covers designed to withstand energy deposition. If the diagnostic contained in the port must communicate with the vessel volume, a shutter assembly is usually provided. In the ports at 285 degrees, R+1 and R-1, interferometer mirrors have been installed to provide a means for transmitting a large diameter CO-2 laser beam through the edge of the plasma. To protect the mirrors and other hardware contained in these ports, a special protective plate and shutter arrangement has been designed. This report describes the details of design, fabrication, and installation of these protective covers and shutters

  12. Diagnostic planning in JT-60 project

    International Nuclear Information System (INIS)

    Matoba, Tohru; Suzuki, Yasuo; Funahashi, Akimasa; Itagaki, Tokiyoshi

    1977-08-01

    The diagnostic plans of JT-60 were made along with design of the main machine. Basic requirements of the diagnostic program are (1) multiple measurement of respective plasma parameters, (2) efficient usage of the discharge, (3) capable data acquisition system, (4) high reliability of the diagnostic equipments, and (5) systematic development of new diagnostic techniques. Dimensions of the diagnostic ports were determined in detailed design of the vacuum vessel, anticipating the possible diagnostic methods. The proposed diagnostic systems and the plans are shown in table and figures respectively. Problems in the diagnostics are also described. (auth.)

  13. 360 PORT MDA - A Strategy to Improve Port Security

    Science.gov (United States)

    2006-09-01

    Participating Agencies (After: Executive Briefing..........................27 Table 6. Designated Joint Operations Center Participants (From: SAFE...Investigations CGIP Coast Guard Intelligence Program CHOC Charleston Harbor Operations Center CIO Command Intelligence Officer CMT Combating Maritime... EXECUTIVE SUMMARY Ports are critical to our economy and national security. Key hubs in the international trade network, U.S. ports accounted for more than

  14. Conceptual Model Development of Sustainability Practices: The Case of Port Operations for Collaboration and Governance

    Directory of Open Access Journals (Sweden)

    Dalwon Kang

    2017-12-01

    Full Text Available Sustainability practices in port operations are critical issue to achieve port sustainability involving economic, social and environmental issues. To assist ports to successfully implant sustainability practices into their operations, this paper conceptualized the structure of sustainability practices in international port operations, by clustering the relevant issues, empirically. Using 203 samples collected from port stakeholders in the major ports in Northeast Asia, multi-measurement items were analyzed on exploratory factor analysis in SPSS 21. Results generated a structure that consists of five sub-dimensions conceptualizing sustainability practices in the context of port operations. As operative practices to accommodate current and future demands in a port, the five-factor model clustering the relevant issues incorporate environmental technologies, process and quality improvement, monitoring and upgrading, communication and cooperation, and active participation. Providing useful insights for strategic agenda to assist ports to incorporate sustainability practices in their operations, the five-factor model offer both a descriptive and diagnostic management tool for future improvement in port operations.

  15. A study on stress corrosion cracking of explosive plugged part

    International Nuclear Information System (INIS)

    Kaga, Seiichi; Fujii, Katsuhiro; Yamamoto, Yoshiaki; Sakuma, Koosuke; Hibi, Seiji; Morimoto, Hiroyoshi.

    1986-01-01

    Studies on the stress corrosion cracking of explosive plugged part are conducted. SUS 304 stainless steel is used as testing material. The distribution of residual stress in plug and tube plate after plugging is obtained. The effect of residual stress on the stress corrosion cracking is studied. Residual stress in tube plate near the plug is compressive and stress corrosion cracking dose not occur in the tube plate there, and it occurs on the inner surface of plug because of residual tensile stress in axial direction of the plug. Stress corrosion test in MgCl 2 solution under constant load is conducted. The susceptibility to stress corrosion cracking of the explosive bonded boundary is lower than that of base metal because of greater resistance to plastic deformation. Stress corrosion test in high temperature and high pressure pure water is also conducted by means of static type of autoclave but stress corrosion cracking does not occur under the testing condition used. (author)

  16. Mucous plug syndrome. A pulmonary embolism mimic

    International Nuclear Information System (INIS)

    Bray, S.T.; Johnstone, W.H.; Dee, P.M.; Pope, T.L. Jr.; Teates, C.D.; Tegtmeyer, C.J.

    1984-01-01

    Reported are ten instances of major bronchial obstruction by mucous plugs in eight patients during which the clinical features resembled pulmonary embolism. Perfusion lung studies showed significantly diminished perfusion of the involved portions of the lungs. The chest radiographs generally did not, however, reflect the severity of the airway obstruction and in some instances were completely normal. The ventilation studies indicated the extent and severity of the obstruction and matched with the perfusion scans. Pulmonary arteriograms were performed in three patients and gave direct evidence of focally diminished lung perfusion without embolism. The physiologic mechanisms underlying the condition are discussed

  17. Plug ‘n’ Play with DNA

    DEFF Research Database (Denmark)

    Lund, Anne Mathilde; Andreasen, Elisa W.; Korgaard, Jaide V.

    Synthetic biology has evolved dramatically within the past decade, which calls for a revolution of the Standard Assembly method that makes the foundation of BioBricks. We believe that iGEM should be about fast assembly of BioBricks, where any thinkable part, device or existing BioBrick can be com...... be combined for any type of organism within one day. Therefore, we have designed a new BioBrick Kit based on a novel assembly standard; called “Plug 'n' Play with DNA”....

  18. Thermographic study of the preheating plugs in diesel engines

    OpenAIRE

    Royo Pastor, Rafael; Albertos Arranz, M.A.; CÁRCEL CUBAS, JUAN ANTONIO; Payá Herrero, Jorge

    2012-01-01

    The use of direct injection diesel engines has been widely applied during the past ten years. In such engines, the preheating plugs are a key element which has a significant contribution in the pollutant emissions. In this paper, two different plug designs from Renault are analyzed. The new plug reduces substantially the required electrical consumption. Nevertheless, the pollutant emissions are higher (fundamentally CO and HCs) and hereby a thorough analysis is required to underst...

  19. Container Traffic In European Ports

    Directory of Open Access Journals (Sweden)

    Elen Twrdy

    2004-03-01

    Full Text Available Over the last fifteen years the European transport markethas witnessed a growth of container traffic which today reachesapproximately 50 million TEU per year. From 1997 to 2002,container traffic in the northern European ports increased from14 to 20.6 million TEU per year, in the ports of the westernMedite"anean from 6 to 10 million TEU per year, and in thenorthern Adriatic ports from 0. 69 to 0. 74 million TEU per year.The ports of the northern Adriatic are located in three states(Slovenia, Croatia and Italy with different statuses in relationto the common European market. In addition, different developmentlevels of these states are reflected in different levels ofinternational commercial exchange, the development of the existinginfrastructure and plans for the construction of new infrastructures.However, all three countries share a common goaltoincrease their competitiveness in comparison with the westemEuropean ports.

  20. Principles of subcutaneous port placement.

    Science.gov (United States)

    Gonda, Shaun J; Li, Ruizong

    2011-12-01

    The introduction of totally implantable subcutaneous devices in the early 1980s provided patients with secure, reliable venous access and also gave them the ability to move more freely and have a more normal lifestyle with these devices in place. The most common totally implantable device used today is the subcutaneous port. These ports consist of an injection port connected to a catheter. Ports provide a number of advantages compared with other venous catheters; the most important is the reduced risk of infection. These devices have significantly lower rates of infection than nontunneled and tunneled catheters. Additional advantages include less frequent irrigation and minimal home care, and they are less prone to environmental or cutaneous contamination when not being accessed. This article will focus on the placement of these ports. Copyright © 2011 Elsevier Inc. All rights reserved.

  1. Knowledge-Based System to Support Plug Load Management

    Data.gov (United States)

    National Aeronautics and Space Administration — Electrical plug loads comprise an increasingly larger share of building energy consumption as improvements have been made to Heating, Ventilation, and Air...

  2. Mechanical Properties of Plug Welds after Micro-Jet Cooling

    OpenAIRE

    Hadryś D.

    2016-01-01

    New technology of micro-jet welding could be regarded as a new way to improve mechanical properties of plug welds. The main purpose of that paper was analyzing of mechanical properties of plug welds made by MIG welding method with micro-jet cooling. The main way for it was comparison of plug welds made by MIG welding method with micro-jet cooling and plug welds made by ordinary MIG welding method. It is interesting for steel because higher amount of acicular ferrite (AF) in weld metal deposit...

  3. An Overview of the HomePlug AV2 Technology

    OpenAIRE

    Yonge, Larry; Abad, Jose; Afkhamie, Kaywan; Guerrieri, Lorenzo; Katar, Srinivas; Lioe, Hidayat; Pagani, Pascal; Riva, Raffaele; Schneider, Daniel M.; Schwager, Andreas

    2013-01-01

    HomePlug AV2 is the solution identified by the HomePlug Alliance to achieve the improved data rate performance required by the new generation of multimedia applications without the need to install extra wires. Developed by industry-leading participants in the HomePlug AV Technical Working Group, the HomePlug AV2 technology provides Gigabit-class connection speeds over the existing AC wires within home. It is designed to meet the market demands for the full set of future in-home networking co...

  4. Single port laparoscopic surgery

    DEFF Research Database (Denmark)

    Springborg, Henrik; Istre, Olav

    2012-01-01

    LESS, or laparo-endoscopic single site surgery, is a promising new method in minimally invasive surgery. An increasing number of surgical procedures are being performed using this technique, however, its large-scale adoption awaits results of prospective randomized controlled studies confirming...... potential benefits. Theoretically, cosmetic outcomes, postoperative pain and complication rates could be improved with use of single site surgery. This study describes introduction of the method in a private hospital in Denmark, in which 40 patients have been treated for benign gynecologic conditions....... Although the operations described are the first of their kind reported in Denmark, favorable operating times and very low complication rates are seen. It is the authors' opinion that in addition to being feasible for hysterectomy, single port laparoscopy may become the preferred method for many simple...

  5. Detailed Design and Fabrication Method of the ITER Vacuum Vessel Ports

    International Nuclear Information System (INIS)

    Hee-Jae Ahn; Kwon, T.H.; Hong, Y.S.

    2006-01-01

    The engineering design of the ITER vacuum vessel (VV) has been progressed by the ITER International Team (IT) with the cooperation of several participant teams (PT). The VV and ports are the components allocated to Korea for the construction of the ITER. Hyundai Heavy Industries has been involved in the structural analysis, detailed design and development of the fabrication method of the upper and lower ports within the framework of the ITER transitional arrangements (ITA). The design of the port structures has been investigated to validate and to improve the conceptual designs of the ITER IT and other PT. The special emphasis was laid on the flange joint between the port extension and the in-port plug to develop the design of the upper port. The modified design with a pure friction type flange with forty-eight pieces of bolts instead of the tangential key is recommended. Furthermore, the alternative flange designs developed by the ITER IT have been analyzed in detail to simplify the lip seal maintenance into the port flange. The structural analyses of the lower RH port have been also performed to verify the capacity for supporting the VV. The maximum stress exceeds the allowable value at the reinforcing block and basement. More elaborate local models have been developed to mitigate the stress concentration and to modify the component design. The fabrication method and the sequence of the detailed fabrication for the ports are developed focusing on the cost reduction as well as the simplification. A typical port structure includes a port stub, a stub extension and a port extension with a connecting duct. The fabrication sequence consists of surface treatment, cutting, forming, cleaning, welding, machining, and non-destructive inspection and test. Tolerance study has been performed to avoid the mismatch of each fabricated component and to obtain the suitable tolerances in the assembly at the shop and site. This study is based on the experience in the fabrication of

  6. Ford C-Max plug-in hybrid; Ford C-Max mit Plug-in-Hybridtechnik

    Energy Technology Data Exchange (ETDEWEB)

    Schamel, Andreas; D' Annunzio, Julie; Iorio, Rob [Ford Motor Company, Dearborn, MI (United States); Schmitz, Peter [Ford-Forschungszentrum Aachen GmbH, Aachen (Germany)

    2013-03-01

    Ford provides consumers a broad choice of electrified vehicles globally, including full hybrids, plug-in hybrids and all-electric vehicles. The all-new 2013 model year C-Max Energi Plug-in Hybrid utilises the third generation of Ford hybrid technology. This article discusses the hybrid powersplit architecture and components, as well as the charging capability and human-machine interfaces, used in the C-Max Energi Plug-In Hybrid. (orig.)

  7. Deep Space Habitat Wireless Smart Plug

    Science.gov (United States)

    Morgan, Joseph A.; Porter, Jay; Rojdev, Kristina; Carrejo, Daniel B.; Colozza, Anthony J.

    2014-01-01

    NASA has been interested in technology development for deep space exploration, and one avenue of developing these technologies is via the eXploration Habitat (X-Hab) Academic Innovation Challenge. In 2013, NASA's Deep Space Habitat (DSH) project was in need of sensors that could monitor the power consumption of various devices in the habitat with added capability to control the power to these devices for load shedding in emergency situations. Texas A&M University's Electronic Systems Engineering Technology Program (ESET) in conjunction with their Mobile Integrated Solutions Laboratory (MISL) accepted this challenge, and over the course of 2013, several undergraduate students in a Capstone design course developed five wireless DC Smart Plugs for NASA. The wireless DC Smart Plugs developed by Texas A&M in conjunction with NASA's Deep Space Habitat team is a first step in developing wireless instrumentation for future flight hardware. This paper will further discuss the X-Hab challenge and requirements set out by NASA, the detailed design and testing performed by Texas A&M, challenges faced by the team and lessons learned, and potential future work on this design.

  8. Biomass plug development and propagation in porous media.

    Science.gov (United States)

    Stewart, T L; Fogler, H S

    2001-02-05

    Exopolymer-producing bacteria can be used to modify soil profiles for enhanced oil recovery or bioremediation. Understanding the mechanisms associated with biomass plug development and propagation is needed for successful application of this technology. These mechanisms were determined from packed-bed and micromodel experiments that simulate plugging in porous media. Leuconostoc mesenteroides was used, because production of dextran, a water-insoluble exopolymer, can be controlled by using different carbon sources. As dextran was produced, the pressure drop across the porous media increased and began to oscillate. Three pressure phases were identified under exopolymer-producing conditions: the exopolymer-induction phase, the plugging phase, and the plug-propagation phase. The exopolymer-induction phase extended from the time that exopolymer-producing conditions were induced until there was a measurable increase in pressure drop across the porous media. The plugging phase extended from the first increase in pressure drop until a maximum pressure drop was reached. Changes in pressure drop in these two phases were directly related to biomass distribution. Specifically, flow channels within the porous media filled with biomass creating a plugged region where convective flow occurred only in water channels within the biofilm. These water channels were more restrictive to flow causing the pressure drop to increase. At a maximum pressure drop across the porous media, the biomass yielded much like a Bingham plastic, and a flow channel was formed. This behavior marked the onset of the plug-propagation phase which was characterized by sequential development and breakthrough of biomass plugs. This development and breakthrough propagated the biomass plug in the direction of nutrient flow. The dominant mechanism associated with all three phases of plugging in porous media was exopolymer production; yield stress is an additional mechanism in the plug-propagation phase. Copyright

  9. Absorbed decay-photon dose analysis of the IVVS/GDC plug in ITER

    Energy Technology Data Exchange (ETDEWEB)

    Leichtle, D.; Serikov, A.; Fischer, U. [Karlsruhe Institute of Technology (KIT), Eggenstein-Leopoldshafen (DE). Inst. for Neutron Physics and Reactor Technology (INR)

    2011-07-01

    The In-Vessel Viewing System (IVVS) and the Glow Discharge Cleaning (GDC) unit share a common port at the equatorial level of the ITER tokamak. The plug consists mainly of the IWS probe, capable of performing the laser-based in-vessel viewing and metrology, the GDC electrode, capable of producing glow discharge in the vacuum vessel during intermediate maintenance and wall conditioning periods, and their respective deployment systems to move the electrodes. The plug extends over a length of about 11 m from the GDC tip to the rear end at the bioshield level. At the present stage of the conceptual design a neutronics analysis has been requested to provide valuable input to the design strategy. To this end, a first assessment has been performed focusing on operational loads on the GDC electrode head in the so-called shielding position and on absorbed decay-photon dose rate levels in the structural components of the entire system. In this contribution we are reporting on the absorbed dose rates after the ITER life time irradiation at several cooling times. Gamma sources from activated materials of the IVVS/GDC and surrounding structures, like blanket, vacuum vessel, toroidal and poloidal field coils, have been taken into account. (orig.)

  10. Concerning background from calorimeter ports

    International Nuclear Information System (INIS)

    Digiacomo, N.J.

    1985-01-01

    Any detector system viewing a port or slit in a calorimeter wall will see, in addition to the primary particles of interest, a background of charged and neutral particles and photons generated by scattering from the port walls and by leakage from incompletely contained primary particle showers in the calorimeter near the port. The signal to noise ratio attainable outside the port is a complex function of the primary source spectrum, the calorimeter and port design and, of course, the nature and acceptance of the detector system that views the port. Rather than making general statements about the overall suitability (or lack thereof) of calorimeter ports, we offer here a specific example based on the external spectrometer and slit of the NA34 experiment. This combination of slit and spectrometer is designed for fixed-target work, so that the primary particle momentum spectrum contains higher momentum particles than expected in a heavy ion colliding beam environment. The results are, nevertheless, quite relevant for the collider case

  11. Shutdown dose rate analysis of European test blanket modules shields in ITER Equatorial Port #16

    Energy Technology Data Exchange (ETDEWEB)

    Juárez, Rafael, E-mail: rjuarez@ind.uned.es [Departamento de Ingeniería Energética, ETSII-UNED, Calle Juan del Rosal 12, Madrid 28040 (Spain); Sauvan, Patrick; Perez, Lucia [Departamento de Ingeniería Energética, ETSII-UNED, Calle Juan del Rosal 12, Madrid 28040 (Spain); Panayotov, Dobromir; Vallory, Joelle; Zmitko, Milan; Poitevin, Yves [Fusion for Energy (F4E), Torres Diagonal Litoral B3, Josep Pla 2, Barcelona 08019 (Spain); Sanz, Javier [Departamento de Ingeniería Energética, ETSII-UNED, Calle Juan del Rosal 12, Madrid 28040 (Spain)

    2016-11-01

    Highlights: • Nuclear analysis for European TBMs and shields, in ITER Equatorial Port #16, has been conducted in support of the ‘Concept Design Review’ from ITER. • The objective of the work is the characterization of the Shutdown Dose Rates at Equatorial Port #16 interspace. • The role played by the TBM and TBM shields, the equatorial port gaps and the vacuum vessel permeation, in terms of neutron flux transmission is assessed. • The role played by the TBM, TBM shields, Port Plug Frame, Pipe Forest and the machine in terms of activation is also investigated. - Abstract: ‘Fusion for Energy’ (F4E) is designing, developing, and implementing the European Helium-Cooled Lead-Lithium (HCLL) and Helium-Cooled Pebble-Bed (HCPB) Test Blanket Systems (TBSs) for ITER (Nuclear Facility INB-174). An essential element of the Conceptual Design Review (CDR) of these TBSs is the demonstration of capability of Test Blanket Modules (TBM) and their shields to fulfil their function and comply with the design requirements. One of the TBM shields highly relevant design aspects is the project target for shutdown dose rates (SDDR) in the interspace. We investigated two functions of the TBMs and TBM shields—the neutron flux attenuation along the shields, and the reduction of the activation of the components contributing to SDDR. It is shown that TBMs and TBM shields reduce significantly the neutron flux in the port plug (PP). In terms of neutron flux attenuation, the TBM shield provides sufficient neutron flux reduction, being responsible for 5 × 10{sup 6} n/cm{sup 2} s at port interspace, while the EPP gaps and BSM gaps are responsible for 5 × 10{sup 7} n/cm{sup 2} s each. When considering closed upper, lower and lateral neighbour equatorial ports (thus, excluding the cross-talk between ports), a SDDR of 121 μSv/h averaged near the port closure flange was obtained, out of which, only 4 μSv/h are due to the activation of TBMs and TBM shields. Maximum SDDR in the range

  12. Developing quality standards for physical properties of mineral wool plugs

    NARCIS (Netherlands)

    Blok, C.; Berg, van den C.C.; Winkel, van A.

    2014-01-01

    The KIWA certification guidelines for mineral wool products contain standards for slabs and blocks. Propagators would like to introduce quality standards for mineral wool plugs as well. Main concerns were effects of too dense plugs on plant growth, and handling problems with too fluffy or broken

  13. Plug and Play Process Control of a District Heating System

    DEFF Research Database (Denmark)

    Trangbaek, Klaus; Knudsen, Torben; Skovmose Kallesøe, Carsten

    2009-01-01

    The main idea of plug and play process control is to initialise and reconfigure control systems automatically. In this paper these ideas are applied to a scaled laboratory model of a district heating pressure control system.  First of all this serves as a concrete example of plug and play control...

  14. Capillarity Induced Negative Pressure of Water Plugs in Nanochannels

    NARCIS (Netherlands)

    Tas, Niels Roelof; Mela, P.; Kramer, Tobias; Berenschot, Johan W.; van den Berg, Albert

    2003-01-01

    We have found evidence that water plugs in hydrophilic nanochannels can be at significant negative pressure due to tensile capillary forces. The negative pressure of water plugs in nanochannels induces bending of the thin channel capping layer, which results in a visible curvature of the liquid

  15. Plug-in hybrid electric vehicles in dynamical energy markets

    NARCIS (Netherlands)

    Kessels, J.T.B.A.; Bosch, P.P.J. van den

    2008-01-01

    The plug-in hybrid electric vehicle allows vehicle propulsion from multiple internal power sources. Electric energy from the grid can be utilized by means of the plug-in connection. An on-line energy management (EM) strategy is proposed to minimize the costs for taking energy from each power source.

  16. Analyzing the Risk of Well Plug Failure after Abandonment

    International Nuclear Information System (INIS)

    Mainguy, M.; Longuemare, P.; Audibert, A.; Lecolier, E.

    2007-01-01

    All oil and gas wells will have to be plugged and abandoned at some time. The plugging and abandonment procedure must provide an effective isolation of the well fluids all along the well to reduce environmental risks of contamination and prevent from costly remedial jobs. Previous works have analyzed the plug behavior when submitted to local pressure or thermal changes but no work has looked to the effects of external pressure, thermal and stress changes resulting from a global equilibrium restoration in a hydrocarbon reservoir once production has stopped. This work estimates those changes after abandonment on a reservoir field case using a reservoir simulator in conjunction with a geomechanical simulator. Such simulations provide the pressure and thermal changes and the maximum effective stress changes in the reservoir cap rock where critical plugs are put in place for isolating the production intervals. These changes are used as loads in a well bore stress model that explicitly models an injector well and predict stress rearrangements in the plug after abandonment. Results obtained with the well bore stress model for a conventional class G cement plug show that the main risk of failure is tensile failure because of the low tensile strength of the cement. Actually, soft sealing materials or initially pre-stressed plug appears to be more adapted to the downhole conditions changes that may occurs after well plugging and abandonment. (authors)

  17. Dual Spark Plugs For Stratified-Charge Rotary Engine

    Science.gov (United States)

    Abraham, John; Bracco, Frediano V.

    1996-01-01

    Fuel efficiency of stratified-charge, rotary, internal-combustion engine increased by improved design featuring dual spark plugs. Second spark plug ignites fuel on upstream side of main fuel injector; enabling faster burning and more nearly complete utilization of fuel.

  18. California Statewide Plug-In Electric Vehicle Infrastructure Assessment

    Energy Technology Data Exchange (ETDEWEB)

    Melaina, Marc; Helwig, Michael

    2014-05-01

    The California Statewide Plug-In Electric Vehicle Infrastructure Assessment conveys to interested parties the Energy Commission’s conclusions, recommendations, and intentions with respect to plug-in electric vehicle (PEV) infrastructure development. There are several relatively low-risk and high-priority electric vehicle supply equipment (EVSE) deployment options that will encourage PEV sales and

  19. National Plug-In Electric Vehicle Infrastructure Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Wood, Eric [National Renewable Energy Lab. (NREL), Golden, CO (United States); Rames, Clement [National Renewable Energy Lab. (NREL), Golden, CO (United States); Muratori, Matteo [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2017-09-15

    This report addresses the fundamental question of how much plug-in electric vehicle (PEV) charging infrastructure—also known as electric vehicle supply equipment (EVSE)—is needed in the United States to support both plug-in hybrid electric vehicles (PHEVs) and battery electric vehicles (BEVs).

  20. Eddy current inspection of steam generator tubing plugs

    International Nuclear Information System (INIS)

    Cullen, W.K.

    1990-01-01

    In response to the issues raised regarding the integrity of nuclear steam generator tubing plugs manufactured from certain heats of Inconel 600, Westinghouse engineers have developed, qualified and implemented an eddy current inspection system for the in-place assessment of these plugs. The heart of the system is a robotic and effector which delivers an eddy current sensor through the reduced diameter of the plug expander and actuates the coil to physical contact with the expanded inside bore of the plug. Once deployed, the eddy current sensor is rotated along a helical path to produce a detailed scan of the plug surface above the final position of the expander. This testing produces an isometric display of degradation due to primary water stress corrosion cracking, on the inside surface of the plug. To date, successful inspections have been conducted at two nuclear units with two different robotic delivery systems. While designed specifically for mechanical plugs with a bottle bore cavity, the inspection system can also be used for expanded straight bore plugs. Details of the inspection system along with a discussion of qualification activities and actual field results are presented in this paper

  1. Proceedings of the workshop on borehole and shaft plugging

    International Nuclear Information System (INIS)

    1980-01-01

    Geologic disposal of radioactive waste relies on the capability of many geological formations to provide long-term containment of the waste. The disposal operations could significantly modify the original conditions. In addition to the underground excavations and the thermal input of the waste their is the problem of boreholes and shafts that constitute a potential by-pass of the geological barriers. It is therefore essential to develop techniques and procedures for effective plugging of all penetrations connecting the disposal zone with the surface or with water bearing layers. It will be necessary to produce plugs which effectively restore the original characteristics of the isolating formations. In addition these plugs must be chemically stable in the existing geochemical environment in order to remain effective for very long periods of time and the plugs of disposal holes can be exposed to high temperatures and radiation doses. All countries with geologic disposal programmes will have to face the problem of borehole and shapt plugging

  2. Development of sealing plug for sweep gas line

    International Nuclear Information System (INIS)

    Kikuchi, Taiji; Yamada, Hirokazu; Saitoh, Takashi; Nakamichi, Masaru; Tsuchiya, Kunihiko; Kawamura, Hiroshi

    2004-03-01

    On the irradiation capsule for neutron irradiation test of the tritium breeder, the sealing plug is necessary to prevent a leak of tritium gas when the tritium breeder is picked up from the irradiation capsule after irradiation test. However, the general valve and plug cannot apply to sealing of the sweep gas line because of the following factors, the neutron irradiation effect, limited space in the irradiation capsule, high sealing efficiency, simple method and operation for control. Therefore, the sealing plug for sweep gas line has to be developed. This paper reports the development of the sealing plug for sweep gas line and the operating procedure of the sealing plug in the irradiation capsule. (author)

  3. A Genre Classification Plug-in for Data Collection

    DEFF Research Database (Denmark)

    Lehn-Schiøler, Tue; Arenas-García, Jerónimo; Petersen, Kaare Brandt

    2006-01-01

    This demonstration illustrates how the methods developed in the MIR community can be used to provide real-time feedback to music users. By creating a genre classifier plug-in for a popular media player we present users with relevant information as they play their songs. The plug-in can furthermor...... be used as a data collection platform. After informed consent from a selected set of users the plug-in will report on music consumption behavior back to a central server.......This demonstration illustrates how the methods developed in the MIR community can be used to provide real-time feedback to music users. By creating a genre classifier plug-in for a popular media player we present users with relevant information as they play their songs. The plug-in can furthermore...

  4. Borehole plugging by compaction process. Final report

    International Nuclear Information System (INIS)

    Fernandez, R.; MacGowan, C.; Nolan, E.; Morey, R.; Palty, A.

    1976-08-01

    The requirements of an overall program to preserve the integrity of a repository formation are documented. The repository is intended to be in stable earth stratum used as a safe and permanent storage area for nuclear waste material. These wastes represent an environmental hazard for a period of up to 200,000 years. An engineering analysis, a reliability and quality-assurance program, and a development program for borehole plugging by compaction process, using natural earthen materials, are presented. Part 1 provides the engineering analysis of downhole compaction methods and related instrumentation along with a recommended development plan from concept through a pilot in-situ experiment. Part 2 provides a reliability and quality-assurance program from laboratory testing of materials through an in-situ experiment

  5. Mitigation of Syngas Cooler Plugging and Fouling

    Energy Technology Data Exchange (ETDEWEB)

    Bockelie, Michael J. [Reaction Engineering International, Salt Lake City, UT (United States)

    2015-06-29

    This Final Report summarizes research performed to develop a technology to mitigate the plugging and fouling that occurs in the syngas cooler used in many Integrated Gasification Combined Cycle (IGCC) plants. The syngas cooler is a firetube heat exchanger located downstream of the gasifier. It offers high thermal efficiency, but its’ reliability has generally been lower than other process equipment in the gasification island. The buildup of ash deposits that form on the fireside surfaces in the syngas cooler (i.e., fouling) lead to reduced equipment life and increased maintenance costs. Our approach to address this problem is that fouling of the syngas cooler cannot be eliminated, but it can be better managed. The research program was funded by DOE using two budget periods: Budget Period 1 (BP1) and Budget Period 2 (BP2). The project used a combination of laboratory scale experiments, analysis of syngas cooler deposits, modeling and guidance from industry to develop a better understanding of fouling mechanisms and to develop and evaluate strategies to mitigate syngas cooler fouling and thereby improve syngas cooler performance. The work effort in BP 1 and BP 2 focused on developing a better understanding of the mechanisms that lead to syngas cooler plugging and fouling and investigating promising concepts to mitigate syngas cooler plugging and fouling. The work effort focused on the following: • analysis of syngas cooler deposits and fuels provided by an IGCC plant collaborating with this project; • performing Jet cleaning tests in the University of Utah Laminar Entrained Flow Reactor to determine the bond strength between an ash deposit to a metal plate, as well as implementing planned equipment modifications to the University of Utah Laminar Entrained Flow Reactor and the one ton per day, pressurized Pilot Scale Gasifier; • performing Computational Fluid Dynamic modeling of industrially relevant syngas cooler configurations to develop a better

  6. Plugging criteria for WWER SG tubes

    Energy Technology Data Exchange (ETDEWEB)

    Papp, L.; Wilam, M. [Vitkovice NPP Services (Switzerland); Herman, M. [Vuje, Trnava (Slovakia)

    1997-12-31

    At operated Czech and Slovak nuclear power plants the 80 % criteria for crack or other bulk defect depth is used for steam generator heat exchanging tubes plugging. This criteria was accepted as the recommendation of designer of WWER steam generators. Verification of this criteria was the objective of experimental program performed by Vitkovice, J.S.C., UJV Rez, J.S.C. and Vuje Trnava, J.S.C .. Within this program the following factors were studied: (1) Influence of secondary water chemistry on defects initiation and propagation, (2) Statistical evaluation of corrosion defects progression at operated SG, and (3) Determination of critical pressure for tube rupture as a function of eddy current indications. In this presentation items (2) and (3) are considered.

  7. Welding nuclear reactor fuel rod end plugs

    International Nuclear Information System (INIS)

    Yeo, D.

    1984-01-01

    Apparatus for applying a vacuum to a nuclear fuel rod cladding tube's interior through its open end while girth welding an inserted end plug to its other end. An airtight housing has an orifice with a seal which can hermetically engage the tube's open end. A vacuum hose has one end connected to the housing and the other end connected to a vacuum pump. A mechanized device which moves the housing to engage or disengage its seal with the tube's open end includes at least one arm having one end attached to the housing and the other end pivotally attached to a movable table; an arm rotating device to coaxially align the housing's orifice with the welding-positioned tube; and a table moving device to engage the seal of the coaxially aligned orifice with the tube's open end. (author)

  8. Experimental plug and play quantum coin flipping

    Science.gov (United States)

    Pappa, Anna; Jouguet, Paul; Lawson, Thomas; Chailloux, André; Legré, Matthieu; Trinkler, Patrick; Kerenidis, Iordanis; Diamanti, Eleni

    2014-04-01

    Performing complex cryptographic tasks will be an essential element in future quantum communication networks. These tasks are based on a handful of fundamental primitives, such as coin flipping, where two distrustful parties wish to agree on a randomly generated bit. Although it is known that quantum versions of these primitives can offer information-theoretic security advantages with respect to classical protocols, a demonstration of such an advantage in a practical communication scenario has remained elusive. Here we experimentally implement a quantum coin flipping protocol that performs strictly better than classically possible over a distance suitable for communication over metropolitan area optical networks. The implementation is based on a practical plug and play system, developed by significantly enhancing a commercial quantum key distribution device. Moreover, we provide combined quantum coin flipping protocols that are almost perfectly secure against bounded adversaries. Our results offer a useful toolbox for future secure quantum communications.

  9. Plugging criteria for WWER SG tubes

    Energy Technology Data Exchange (ETDEWEB)

    Papp, L; Wilam, M [Vitkovice NPP Services (Switzerland); Herman, M [Vuje, Trnava (Slovakia)

    1998-12-31

    At operated Czech and Slovak nuclear power plants the 80 % criteria for crack or other bulk defect depth is used for steam generator heat exchanging tubes plugging. This criteria was accepted as the recommendation of designer of WWER steam generators. Verification of this criteria was the objective of experimental program performed by Vitkovice, J.S.C., UJV Rez, J.S.C. and Vuje Trnava, J.S.C .. Within this program the following factors were studied: (1) Influence of secondary water chemistry on defects initiation and propagation, (2) Statistical evaluation of corrosion defects progression at operated SG, and (3) Determination of critical pressure for tube rupture as a function of eddy current indications. In this presentation items (2) and (3) are considered.

  10. Plugging of drinking water flow into horizontal high diameter pipeline with artificial ice plug

    International Nuclear Information System (INIS)

    Gyongyosi, T.; Valeca, S.; Panaitescu, V. N.; Prisecaru, I.

    2013-01-01

    Local isolation of a pipeline section, placed horizontally into a loop of drinking water supply network, can be made with an ice plug resulting after controlled process inside of pipeline without stopping the consumer supply. The technique is applying in order to perform repairs or items replacement, without closing the drinking water supply network at the same time decreasing the fluid loss resulted after discharge of the affected loop. In facts, the technique is simple one and assumes to apply a special device sized for each case using a freezing liquid agent injected continuously. The paper contains a constructive description of the experimental technological facilities and of the experimental model for ice plugging device used. The test, the first results get and some conclusion are following. The paper is dedicated to the specialists working in the research and technological engineering. (authors)

  11. Progress in the integration of Test Blanket Systems in ITER equatorial port cells and in the interfaces definition

    Energy Technology Data Exchange (ETDEWEB)

    Pascal, R., E-mail: romain.pascal@iter.org [ITER Organization, Route de Vinon sur Verdon, 13115 Saint Paul Lez Durance (France); Beloglazov, S.; Bonagiri, S. [ITER Organization, Route de Vinon sur Verdon, 13115 Saint Paul Lez Durance (France); Commin, L. [CEA, IRFM, Cadarache (France); Cortes, P.; Giancarli, L.M.; Gliss, C.; Iseli, M.; Lanza, R.; Levesy, B.; Martins, J.-P. [ITER Organization, Route de Vinon sur Verdon, 13115 Saint Paul Lez Durance (France); Neviere, J.-C. [ITER Organization, Route de Vinon sur Verdon, 13115 Saint Paul Lez Durance (France); Comex-Nucleaire, 13115 Saint Paul Lez Durance (France); Patisson, L.; Plutino, D.; Shu, W. [ITER Organization, Route de Vinon sur Verdon, 13115 Saint Paul Lez Durance (France); Swami, H.L. [Institute for Plasma Research, Bhat, Gandhinagar 382428 (India)

    2012-08-15

    Highlights: Black-Right-Pointing-Pointer The design integration of two test blanket systems in ITER port cell is addressed. Black-Right-Pointing-Pointer Definition of interfaces of TBSs with building and other ITER systems is done. Black-Right-Pointing-Pointer Designs of pipe forest, bioshield plug and ancillary equipment unit are described. Black-Right-Pointing-Pointer The maintenance of the two test blanket systems in ITER port cell is considered. Black-Right-Pointing-Pointer The management of the heat and tritium releases in the TBM port cell is described. - Abstract: In the framework of the TBM Program, three ITER vacuum vessel equatorial ports (no. 16, no. 18 and no. 02) have been allocated for the testing of up to six mock-ups of six different DEMO tritium breeding blankets. Each one is called a Test Blanket System (TBS). A TBS consists mainly of the Test Blanket Module (TBM), the in-vessel component facing the plasma, and several ancillary systems, in particular the cooling system and the tritium extraction system. Each port accommodates two TBMs and therefore the two TBSs have to share the corresponding port cell. This paper deals with the design integration aspects of the two TBSs in each port cell performed at ITER Organization (IO) with the corresponding definition of interfaces with other ITER systems. The performed activities have raised several issues that are discussed in the paper and for which design solutions are proposed.

  12. Strategies for Controlling Plug Loads. A Tool for Reducing Plug Loads in Commercial Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Torcellini, Paul [National Renewable Energy Lab. (NREL), Golden, CO (United States); Bonnema, Eric [National Renewable Energy Lab. (NREL), Golden, CO (United States); Sheppy, Michael [National Renewable Energy Lab. (NREL), Golden, CO (United States); Pless, Shanti [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2015-09-01

    Plug loads are often not considered as part of the energy savings measures in Commercial Buildings; however, they can account for up to 50% of the energy used in the building. These loads are numerous and often scattered throughout a building. Some of these loads are purchased by the owner and some designed into the building or the tenant finishes for a space. This document provides a strategy and a tool for minimizing these loads.

  13. Cyclic variation of heat flux on spark plug; Tenka plug bu no netsuryusoku hendo no sokutei

    Energy Technology Data Exchange (ETDEWEB)

    Ishii, K.; Sasaki, T.; Urata, Y. [Honda Motor Co. Ltd., Tokyo (Japan); Kagawa, J.; Matsutani, W. [NGK Spark Plug Co. Ltd., Nagoya (Japan)

    1998-02-25

    This paper examines the relationship between the magnitude of the heat flux to the spark plug ground electrode, averaged over an 80` crank angle (CA) of early compression stroke, and the initial burning rate, defined as the CA at which 5% of mass is burned. The heat flux was measured by a thin-film thermocouple with the hot junction on the surface of ground electrode. The results demonstrate that faster initial burning rate correlated well with increasing heat flux from the spark plug to the mixture. The difference in the magnitude and direction of the heat flux is associated with the amount of residual gas concentration and thus the results show the effect of residual gas concentration. The cycle-averaged heat flux from the hot junction is 0.367 MW/m{sup 2}, corresponding to a total heat flow of 20 W from the total surface area of ground electrode. This value is about an order of magnitude larger than that previously reported in the literature for locations away from the spark plug, e. g. at the cylinder wall. 11 refs., 9 figs., 1 tab.

  14. Developing the port of Belawan as a modern and international port

    Science.gov (United States)

    Many, N.

    2018-03-01

    This study discusses the processes of government to pass the port development plan in Indonesia with the Port of Belawan and its port expansion as the study case. The study uses a descriptive approach by reviewing and analyzing some of relevant literature as the sources. It also reviews and examines the port development theoretical concepts and models giving attention to the international hub port models resulted from the previous studies. The international hub port aspects assessed to be further applied and compared to the actual situation of the Port of Belawan. This process draws the conclusion on which concept and model the port classified, followed by some recommendations concerning the necessary actions to be taken. The results show that: (1) The port planning regulated in port master plan is the guideline and foundation to implement the port development; (2) Spatial and zoning plan regulations are very important in the preparation, planning, and implementation of port development; (3) It has not provided the necessary facilities and criteria of the global hub port model has not been met completely. The port is strategic to be completely developed as the regional hub port to compete with the major ports of neighboring countries. Eventually, this study requires further analysis to examine the economic feasibility of the Port of Belawan in more comprehensive way functioning as an international hub port along with the ongoing development of Kuala Tanjung Port to achieve its ultimate objectives, among other things, the port effectiveness, efficiency, and competitiveness.

  15. ITER diagnostic system: Vacuum interface

    International Nuclear Information System (INIS)

    Patel, K.M.; Udintsev, V.S.; Hughes, S.; Walker, C.I.; Andrew, P.; Barnsley, R.; Bertalot, L.; Drevon, J.M.; Encheva, A.; Kashchuk, Y.; Maquet, Ph.; Pearce, R.; Taylor, N.; Vayakis, G.; Walsh, M.J.

    2013-01-01

    Diagnostics play an essential role for the successful operation of the ITER tokamak. They provide the means to observe control and to measure plasma during the operation of ITER tokamak. The components of the diagnostic system in the ITER tokamak will be installed in the vacuum vessel, in the cryostat, in the upper, equatorial and divertor ports, in the divertor cassettes and racks, as well as in various buildings. Diagnostic components that are placed in a high radiation environment are expected to operate for the life of ITER. There are approx. 45 diagnostic systems located on ITER. Some diagnostics incorporate direct or independently pumped extensions to maintain their necessary vacuum conditions. They require a base pressure less than 10 −7 Pa, irrespective of plasma operation, and a leak rate of less than 10 −10 Pa m 3 s −1 . In all the cases it is essential to maintain the ITER closed fuel cycle. These directly coupled diagnostic systems are an integral part of the ITER vacuum containment and are therefore subject to the same design requirements for tritium and active gas confinement, for all normal and accidental conditions. All the diagnostics, whether or not pumped, incorporate penetration of the vacuum boundary (i.e. window assembly, vacuum feedthrough etc.) and demountable joints. Monitored guard volumes are provided for all elements of the vacuum boundary that are judged to be vulnerable by virtue of their construction, material, load specification etc. Standard arrangements are made for their construction and for the monitoring, evacuating and leak testing of these volumes. Diagnostic systems are incorporated at more than 20 ports on ITER. This paper will describe typical and particular arrangements of pumped diagnostic and monitored guard volume. The status of the diagnostic vacuum systems, which are at the start of their detailed design, will be outlined and the specific features of the vacuum systems in ports and extensions will be described

  16. ITER diagnostic system: Vacuum interface

    Energy Technology Data Exchange (ETDEWEB)

    Patel, K.M., E-mail: Kaushal.Patel@iter.org [ITER Organization, Route de Vinon sur Verdon, 13115 St Paul-Lez-Durance (France); Udintsev, V.S.; Hughes, S.; Walker, C.I.; Andrew, P.; Barnsley, R.; Bertalot, L. [ITER Organization, Route de Vinon sur Verdon, 13115 St Paul-Lez-Durance (France); Drevon, J.M. [Bertin Technologies, BP 22, 13762 Aix-en Provence cedex 3 (France); Encheva, A. [ITER Organization, Route de Vinon sur Verdon, 13115 St Paul-Lez-Durance (France); Kashchuk, Y. [Institution “PROJECT CENTER ITER”, 1, Akademika Kurchatova pl., Moscow (Russian Federation); Maquet, Ph. [Bertin Technologies, BP 22, 13762 Aix-en Provence cedex 3 (France); Pearce, R.; Taylor, N.; Vayakis, G.; Walsh, M.J. [ITER Organization, Route de Vinon sur Verdon, 13115 St Paul-Lez-Durance (France)

    2013-10-15

    Diagnostics play an essential role for the successful operation of the ITER tokamak. They provide the means to observe control and to measure plasma during the operation of ITER tokamak. The components of the diagnostic system in the ITER tokamak will be installed in the vacuum vessel, in the cryostat, in the upper, equatorial and divertor ports, in the divertor cassettes and racks, as well as in various buildings. Diagnostic components that are placed in a high radiation environment are expected to operate for the life of ITER. There are approx. 45 diagnostic systems located on ITER. Some diagnostics incorporate direct or independently pumped extensions to maintain their necessary vacuum conditions. They require a base pressure less than 10{sup −7} Pa, irrespective of plasma operation, and a leak rate of less than 10{sup −10} Pa m{sup 3} s{sup −1}. In all the cases it is essential to maintain the ITER closed fuel cycle. These directly coupled diagnostic systems are an integral part of the ITER vacuum containment and are therefore subject to the same design requirements for tritium and active gas confinement, for all normal and accidental conditions. All the diagnostics, whether or not pumped, incorporate penetration of the vacuum boundary (i.e. window assembly, vacuum feedthrough etc.) and demountable joints. Monitored guard volumes are provided for all elements of the vacuum boundary that are judged to be vulnerable by virtue of their construction, material, load specification etc. Standard arrangements are made for their construction and for the monitoring, evacuating and leak testing of these volumes. Diagnostic systems are incorporated at more than 20 ports on ITER. This paper will describe typical and particular arrangements of pumped diagnostic and monitored guard volume. The status of the diagnostic vacuum systems, which are at the start of their detailed design, will be outlined and the specific features of the vacuum systems in ports and extensions

  17. Evaluation of preconceptual plug designs using experts' judgement

    International Nuclear Information System (INIS)

    Sioshansi, F.P.; O'Rourke, J.E.

    1980-03-01

    A number of preconceptual plug designs for an underground nuclear waste repository were to be evaluated based on the available information on plug materials and placement techniques. Because of complex environment and loading conditions, long time frame under consideration, rigid performance characteristics and considerable uncertainties present in preconceptual design and material properties, a qualitative and judgmental evaluation procedure was needed to supplement technical studies. A structured procedure was developed to qualitatively capture evaluator's views and reservations on the proposed preconceptual schemes. Since a thorough evaluation of each proposed plug scheme required in-depth experience and familiarity with many components of the plug, three knowledgeable experts with specialties in the most relevant aspects of the problem were independently interviewed. Each plug scheme was broken down into three subcomponents and each subcomponent was evaluated separately. The proposed schemes were then rated taking their subcomponents into consideration. Because the experts had different specialties, their subcomponent and overall ratings were not in full agreement. Each plug scheme's lowest overall rating was used as the most significant determinant of the judgmental preference categories reported in this study. The approach used discriminated between the proposed schemes for those with highest probability of being successful. The most preferred schemes were then reviewed with respect to the data produced in the technical analysis performed during the project. The results of the judgmental analysis were then synthesized and modified with results of the technical analysis to produce the preconceptual plug designs

  18. Development of weld plugging for steam generator tubes of FBR

    International Nuclear Information System (INIS)

    Shimoyama, T.; Matsuyama, T.; Matsumoto, O.; Nagura, Y.; Nakamura, H.; Tohguchi, Y.; Kurokawa, M.; Fukada, T.

    2002-01-01

    This study was undertaken to develop a method of weld plugging of the heat-exchanger tubes of steam generator of Prototype FBR 'MONJU' in case these tubes are damaged for some reason. We studied mainly the shape of plug, welding procedure and effect of postweld heat treatment (PWHT). Evaporator tube sheet, tube and plug are made of 2-1/4Cr-1Mo steel and usually preheating and PWHT will be required for welding of this steel. The results of this study is as follows. 1) Plug was designed to make butt joint welding with grooved tube sheet around the tube hole to satisfy the requirements of plug designing, stress analysis, and good weldability. 2) TIG welding process was selected and certified its good weldability and good performance. 3) PWHT can be done by using high frequency induction heating method locally and also designing the plug to weld joint with tube sheet which was grooved around the tube hole. 4) Mock up test was done and it was certified that this plugging procedure has good weldability and good performance ability for Non Destructive Inspection. (author)

  19. Borehole plugging by hydrothermal transport. A feasibility report

    International Nuclear Information System (INIS)

    Roy, D.M.; White, W.B.

    1975-01-01

    The possibility of forming borehole plugs by hydrothermal transport was examined with respect to five systems, utilizing available literature data. In general, it would appear possible to create plugs with hydrothermal cements, with hydrothermally transported quartz, and with carbonates precipitated in-situ using carbon dioxide or carbon dioxide and water as reacting fluids. Hydrothermal cements appear to be most feasible from an engineering and economic point of view using a slurry with a lime-alumina-silica composition carried into the hole in a single pipe at temperatures in the range of 200 0 C and requiring only enough pressure to drive the mixture into the hole. Quartz or chalcedony plugs would be the most impervious, have the lowest chemical reactivity with groundwater, the lowest thermal expansion, and be most compatible with the wall rock. Deposition is likely to be slow, and there are severe engineering problems associated with a single pipe system carrying silica-rich solutions at temperatures in excess of 500 0 C at pressure of 2000 bars (30,000 psi). Calcite plugs could be formed as compatible plug materials in contact with a limestone or dolomite wall rock. It is not known whether non-porous plugs can be readily formed and there is also a problem of chemical reaction with percolating groundwater. The clay-water and sulfur-water systems do not appear to be viable plug systems. In-situ reconstitution of the wall rock does not appear to be an economically feasible possibility

  20. Maintenance and plugging technology for CANDU steam generator tubing

    International Nuclear Information System (INIS)

    Prince, J.; Nicholson, A.; Hare, J.; McGoey, L.; Stafford, T.; Gowthorpe, P.

    2006-01-01

    In order to keep aging steam generators in service and to successfully manage the life of these critical components, the capability must exist to perform tube plugging and other complex maintenance activities in-situ. In the early days of CANDU steam generator operation, the only option was to perform these activities manually, which had inherent safety and quality risks. The challenge was to be able to perform these activities remotely thus eliminating some of the confined space and radiological exposure risks. The additional challenge was to develop equipment and techniques which would result in significantly improved quality, particularly for the completed plug welds which would be returned to service. Over the past fifteen years, this technology has matured and has produced remarkable results in field application. Some 14000 tube plugs have been successfully installed to date using automated plugging techniques. This paper presents an overview of the development of techniques available to utilities for steam generator tube plugging as well as some highlights of other steam generator tube maintenance activities such as primary side tube removal and tube end damage repair. Aspects covered in the paper include plug and procedure development, automated equipment and manipulators for tool deployment, process controls and personnel requirements. Recently, the steam generator tube plugging performed by OPG has been incorporated into a formal quality program under the requirements of ASME NCA 4000. An overview of the quality program will be presented and details of some of the important aspects of the quality program will be discussed. (author)

  1. Prognostic Enhancements to Diagnostic Systems (PEDS) Applied to Shipboard Power Generation Systems

    National Research Council Canada - National Science Library

    Byington, Carl S; Roemer, Michael J; Watson, Matthew J

    2004-01-01

    .... The current paper describes a framework and development process that allows more plug n play integration of new diagnostic and prognostic technologies using evolving Open System Architecture (OSA) standards...

  2. Mechanical and thermo-mechanical analyses of the tapered plug for plugging of deposition tunnels. A feasibility study

    Energy Technology Data Exchange (ETDEWEB)

    Faelth, Billy (Clay Technology AB, Lund (Sweden)); Gatter, Patrik (Vattenfall Power Consultant AB, Stockholm (Sweden))

    2009-09-15

    This report presents results from a study that was carried out in order to examine the applicability of the tapered plug concept for plugging of deposition tunnels in the deep repository for spent nuclear fuel. The report presents results from mechanical and thermo-mechanical models of the tapered plug. The models were analyzed with 3DEC. The models included a portion of a deposition tunnel and its intersection with a main tunnel. In the deposition tunnel, a tapered concrete plug was installed. The plug was subjected to the combined load from the swelling backfill material and from pore pressure inside the deposition tunnel. The thermo-mechanical effects due to the heat generation in the spent fuel were also included in the analyses. Generic material parameter values for the concrete were used. The following items were studied: - Stresses and displacements in the plug. - Shear stresses and shear displacements in the rock-concrete interface. - Stress additions in the rock due to the loads. The sensitivity of the results to changes of constitutive models, to changes of the plug geometry and to pore water pressure in the rock-concrete interface was examined. The results indicate that the displacements in the plug will be within reasonable ranges but the stresses may locally be high enough that they exceed acceptable levels. However, they can be reduced by choice of advantageous plug geometry and by having a good rock-concrete bond. The results also show that the stress additions in the rock due to the thermal load may yield stresses that locally exceed the spalling strength of the rock. At most locations, however, the rock stresses will amount at lower levels. It was concluded that, with choice of an appropriate design, the tapered plug seems to be an applicable concept for plugging of deposition tunnels. It was also concluded that further studies of the tapered plug concept should use material properties parameter values for low-pH concrete. Further, they should also

  3. Case Studies: Improving Environmental Performance and Economic Prosperity at Ports and in Near-Port Communities

    Science.gov (United States)

    Case Study links for improving environmental performance and economic prosperity at ports and in near-port communities. Case studies on equipment upgrades, jobs and benefits, land use and transportation, port-community engagement, and citizen science.

  4. The viscoelastic properties of the cervical mucus plug

    DEFF Research Database (Denmark)

    Kjær Bastholm, Sara; Becher, Naja; Stubbe, Peter Reimer

    2013-01-01

    The objective of this study was to characterize the viscoelastic properties of cervical mucus plugs (CMPs) shed during labor at term. Spontaneously shed cervical mucus plugs from healthy women in active labor, were tested. The viscoelastic properties of cervical mucus plugs were investigated...... with using frequency and stress sweep experiments within the linear viscoelastic region. Random-effects regression was used for statistical analysis. The CMPs are solid-like viscoelastic structures and the elastic modulus dominated the viscous modulus at all frequencies. These rheological characteristics...

  5. Percutaneous biopsy of malignant hepatic tumor in patients with bleeding tendency : usefulness of gelfoam plugging up the biopsy track

    International Nuclear Information System (INIS)

    Yoon, Hye Ran; Kwak, Byung Kook; Choi, Chi Hoon; Park, Yong Ok; Yang, Keun Myeong; Seo, Ja Young; Lee, Shin Hyung; Lee, Chang Joon; Shim, Hyung Jin

    1998-01-01

    To plug the biopsy site in eight patients with coagulopathy who had undergone percutaneous liver biopsy. To this end, gelfoam cartridge was used as a sealant. Materials and Methods: Using an 18G Tru-Cut-type disposable automated biopsy gun(Soo Ho Medi-tech, Seoul, Korea) and under US guidance, eight patients underwent percutaneous liver biopsy. After the gun had fired, the biopsy specimen in the inner stylet was retrieved while the outer cannula was held in place ; the cannula was then used to plug the biopsy tracks with gelfoam, using two or three cartridges. If bleeding occurred, this was controlled by the use of more gelfoam cartridges. Results:Diagnostic target tissue was obtained in seven of the eight patients(87.5%). Hepatocellular carcinoma was diagnosed in five cases and metastatic cancer in two. Profuse bleeding was observed in one patient(12.5%) and resolved by gelfoam plugging. Conclusion: We believe that in patients with coagulopathy who are required to undergo liver biopsy plugging the liver biopsy track with gelfoam cartridge is a simple, safe and useful method

  6. Reliability of activation cross sections for estimation of shutdown dose rate in the ITER port cell and port interspace

    Science.gov (United States)

    García, Raquel; García, Mauricio; Ogando, Francisco; Pampin, Raúl; Sanz, Javier

    2017-09-01

    This paper explores the quality of available activation cross section (XS) data for accurate Shutdown Dose Rate (SDDR) prediction in the ITER Port Cell and Port Interspace areas, where different maintenance activities are foreseen. For this purpose the EAF library (2007 and 2010 versions) has been investigated, as it is typically used by the ITER community. Based on both reports/papers on SDDR in ITER and own calculations, major nuclides contributing to the SDDR coming from the activation of i) relevant materials placed in ITER and ii) candidate materials for the bioshield plug as L2N and barite concretes, are identified. Then, relevant production pathways are obtained. EAF XS quality for all pathways is checked following the procedure used for validating and testing the successive EAF versions. Also, possible improvements from using the TENDL-2015 library are assessed by comparing EAF and TENDL XS with available differential experimental data from EXFOR. Results point out that most of the activation XS related to materials currently placed in ITER are reliable, and only a few need improvement. Also, many of the XS related to both L2N and barite concretes need further work for validation.

  7. HEPA-filter smoke plugging problem

    International Nuclear Information System (INIS)

    Gaskill, J.R.; Magee, M.W.

    1975-01-01

    Actual experiences indicate that during the early stages of a fire, pyrolysis and incomplete combustion of organic materials used in the furnishings or interior finishes of laboratories yield copious quantities of smoke particulates, both liquid and solid. Furthermore, the use of fire retardants in materials used for the above purpose interferes with the combustion process, so that burning of such materials in later stages of a fire will yield dense smoke. These particulates can plug up a HEPA filter or even a more porous prefilter, and thus effectively shut off the exhaust ventilation. In this case, the fire room will pressurize and contamination may spread in an uncontrolled manner. Both small- and large-scale tests have been conducted to evaluate the nature and degree of the problem as a function of materials involved, rate of exposure to the fire, and kinds and temperatures of smoke so generated. Some test work has also been done on scrubbing of smoke. Proposed future work is described. (U.S.)

  8. Amplatzer vascular plugs in congenital cardiovascular malformations

    International Nuclear Information System (INIS)

    Barwad, Parag; Ramakrishnan, Sivasubramanian; Kothari, Shyam S; Saxena, Anita; Gupta, Saurabh K; Juneja, Rajnish; Gulati, Gurpreet Singh; Jagia, Priya; Sharma, Sanjiv

    2013-01-01

    Amplatzer vascular plugs (AVPs) are devices ideally suited to close medium-to-large vascular communications. There is limited published literature regarding the utility of AVPs in congenital cardiovascular malformations (CCVMs). To describe the use of AVPs in different CCVMs and to evaluate their safety and efficacy. All patients who required an AVP for the closure of CCVM were included in this retrospective review of our catheterization laboratory data. The efficacy and safety of AVPs are reported. A total of 39 AVPs were implanted in 31 patients. Thirteen (33%) were AVP type I and 23 (59%) were AVP type II. AVP type III were implanted in two patients and type IV in one patient. The major indications for their use included closure of pulmonary arteriovenous malformation (AVM) (n = 7), aortopulmonary collaterals (n = 7), closure of a patent Blalock-Taussig shunt (n = 5), systemic AVM (n = 5), coronary AVM (n = 4), patent ductus arteriosus (PDA) (n = 3), pulmonary artery aneurysms (n = 3), and venovenous collaterals (n = 2). Deployment of the AVP was done predominantly via the 5 – 7F Judkin's right coronary guide catheter. Overall 92% of the AVPs could be successfully deployed and resulted in occlusion of the target vessel in all cases, within 10 minutes. No procedure-related or access site complication occurred. AVPs are versatile, easy to use, and effective devices to occlude the vascular communications in a variety of settings. AVP II is especially useful in the closure of tubular structures with a high flow

  9. Cooperation Performance Evaluation between Seaport and Dry Port; Case of Qingdao Port and Xi'an Port

    Directory of Open Access Journals (Sweden)

    Jian Li

    2014-12-01

    Full Text Available Along with the drastic competition among ports, the strive for the vast economic hinterland and the supply of goods have become strategic problems for port operators. At the same time, port enterprises are paying more and more attention to the construction of dry ports. This article establishes the port cooperation performance evaluation index based on the balanced score card method and uses the grey relational degree method to evaluate the cooperation performance between seaports and dry ports. Finally using Qingdao port and Xi'an port as an example, and Zhengzhou port and Lanzhou port as benchmarks, the application of this evaluation method is introduced in detail. The conclusion reveals that cooperation between Qingdao port and Xi'an port has deficiencies in customer satisfaction, financial cooperation and non-market tools. Alongside this, the author proposes related issues about information management in the supply chain, competition position and the scope of hinterland. This article, combined with the related theory of supply chain and performance evaluation, puts forward a set of relatively complete cooperation performance evaluations between seaports and dry ports, which provide scientific theory support for better cooperation.

  10. Mechanical Properties of Plug Welds after Micro-Jet Cooling

    Directory of Open Access Journals (Sweden)

    Hadryś D.

    2016-12-01

    Full Text Available New technology of micro-jet welding could be regarded as a new way to improve mechanical properties of plug welds. The main purpose of that paper was analyzing of mechanical properties of plug welds made by MIG welding method with micro-jet cooling. The main way for it was comparison of plug welds made by MIG welding method with micro-jet cooling and plug welds made by ordinary MIG welding method. It is interesting for steel because higher amount of acicular ferrite (AF in weld metal deposit (WMD is obtained in MIG welding method with micro-jet cooling in relation to ordinary MIG welding method. This article presents the influence of the cooling medium and the number of micro-jet streams on mechanical properties of the welded joint. Mechanical properties were described by force which is necessary to destroy weld joint.

  11. Rotary plug device for use in LMFBR type reactors

    International Nuclear Information System (INIS)

    Azuma, Kazuhiko; Imayoshi, Sho.

    1988-01-01

    Purpose: To prevent adhesion of sodium in the rotational gap of a rotational plug. Constitution: One of the walls of a cylindrical gap formed between the outer circumference of a small rotary plug and a large rotary plug that constitute a double rotary plug is cooled to lower than the sodium coagulation temperature, while a stater of a linear motor in a cylindrical shape and wound with linear coils around the iron core is attached to the inside of the other of the walls. Then, one of the walls of the gap to which sodium adheres is cooled to less than sodium coagulation temperature, so that sodium is or tends to be deposited to the wall. Then, eddy currents are resulted to sodium by the current supplied to the stater of the linear motor attached to the other of the walls, to produce thrusting force. Sodium on the wall surface is scraped off by this. (Yoshihara, H.)

  12. Application of Inductive Monitoring System to Plug Load Anomaly Detection

    Data.gov (United States)

    National Aeronautics and Space Administration — NASA Ames Research Center’s Sustainability Base is a new 50,000 sq. ft. LEED Platinum office building. Plug loads are expected to account for a significant portion...

  13. Modular, Plug and Play, Distributed Avionics, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — The objective of this SBIR effort was to prove the viability of an Ethernet version of the MicroSat Systems, Inc. (MSI) modular, plug and play (PnP) spacecraft...

  14. Setting plug & abandonment barriers with minimum removal of tubulars

    OpenAIRE

    Nessa, Jon Olav

    2012-01-01

    Master's thesis in Petroleum engineering The useful life of an offshore well is determined by the reserves which it contacts, the pressure support within the reservoir and the continued integrity of the wellbore. When a well has reached the end of its lifetime, plugging operations have to be conducted before permanent abandonment. Conventional Plug and Abandonment (P&A) operations will often require removing a section of the casing in order to create cross sectional barriers for well aband...

  15. Nanosatellite and Plug-and-Play Architecture 2 (NAPA 2)

    Science.gov (United States)

    2017-02-28

    development of a 6U- format Space Plug-and-play Architecture (SPA) Research Cubesat (SPARC). SPARC-1 (first and only pursued under this PA) demonstrates...development of a six unit (6U)- format Space Plug-and-play Architecture (SPA) Research Cubesat (SPARC). SPARC-1 (first and only pursued under this PA...computers – More capable, more centralized, bigger wiring bundle Elimination of central computers, distribution of intelligence in systems Rad- hard

  16. Interface Circuit For Printer Port

    Science.gov (United States)

    Tucker, Jerry H.; Yadlowsky, Ann B.

    1991-01-01

    Electronic circuit, called printer-port interface circuit (PPI) developed to overcome certain disadvantages of previous methods for connecting IBM PC or PC-compatible computer to other equipment. Has both reading and writing modes of operation. Very simple, requiring only six integrated circuits. Provides for moderately fast rates of transfer of data and uses existing unmodified circuit card in IBM PC. When used with appropriate software, circuit converts printer port on IBM PC, XT, AT, or compatible personal computer to general purpose, 8-bit-data, 16-bit address bus that connects to multitude of devices.

  17. Effectively reducing emissions from ports

    Energy Technology Data Exchange (ETDEWEB)

    Fazlagic, Ismir; Martelin, Marcus; Skinner, Ryan

    2010-09-15

    Commercial ships calling at more and more ports worldwide can now turn off their diesel engines and tap into cleaner energy sources provided by electrical connections from shore. The technology to make this possible has been in place for over a decade. With a global technology standard due to be ratified by three technical bodies in 2010, high-voltage shore connections will soon get much more attention. Environmentally-minded ports, governments and shipowners are all tuning in to the benefits of supplying electricity to ships at berth. ABB presents the challenge, the technical solution and the business case for all parties involved.

  18. Electric and Plug-In Hybrid Electric Fleet Vehicle Testing | Transportation

    Science.gov (United States)

    Research | NREL Electric and Plug-In Hybrid Electric Fleet Vehicle Evaluations Electric and Plug-In Hybrid Electric Fleet Vehicle Evaluations How Electric and Plug-In Hybrid Electric Vehicles plugging the vehicle into an electric power source. PHEVs are powered by an internal combustion engine that

  19. Reconstitutable control assembly having removable control rods with detachable split upper end plugs

    International Nuclear Information System (INIS)

    Gjertsen, R.K.; Knott, R.P.; Sparrow, J.A.

    1991-01-01

    This patent describes, for use in facilitating replacement of a neutron absorber control rod on a control assembly spider structure, an end plug. It comprises a pair of separate upper and lower plug portions; the upper section of the upper plug portion being configured for rigid attachment; the middle section of the upper plug portion having angularly displaced flat surfaces formed on the exterior

  20. Port Harcourt Medical Journal, a paradigm shift | Eke | Port Harcourt ...

    African Journals Online (AJOL)

    Port Harcourt Medical Journal, a paradigm shift. N Eke. Abstract. No Abstract. Full Text: EMAIL FULL TEXT EMAIL FULL TEXT · DOWNLOAD FULL TEXT DOWNLOAD FULL TEXT · http://dx.doi.org/10.4103/0795-3038.179439 · AJOL African Journals Online. HOW TO USE AJOL... for Researchers · for Librarians · for Authors ...

  1. The VisPort Project: Visualization of Port Logistics

    Science.gov (United States)

    Katsioloudis, Petros J.; Watson, Ginger

    2011-01-01

    There is concern about the diminishing availability of skilled personnel that can operate in the wide variety of disciplines associated with port operations. Increasing cargo volume, combined with a shrinking workforce, could potentially create alarming situations in the future, hence the motivation to publicize to current students the breadth and…

  2. Numerical simulation of ion confinement in the Phaedrus plugs

    International Nuclear Information System (INIS)

    Horne, S.F.

    1984-01-01

    Neutral beams of up to 60 amps were injected into the plugs of the tandem mirror Phaedrus. Substantial heating of the target RF-sustained plasma has been observed, but fueling has been negligible. In order to understand the lack of significant fueling, a model of the trapping and loss processes occurring in the Phaedrus plug was developed, and is presented in this thesis. The model includes neutral beam effects, RF trapping, Coulomb losses, and charge exchange on background gas, in a framework which includes finite gyro-orbit effects. A numerical simulation based on the model is compared to data from 2XIIB and TMX, and shows good agreement. The model is then applied to the Phaedrus plugs, and compared to RF-sustained and neutral-beam data obtained during machine operation in hydrogen and deuterium. The modeling of the Phaedrus plugs indicates that during beam injection, a two-step process occurs that results in the rapid loss of ions. Charge exchange of trapped plasma on the energetic neutral beam causes rapid radial diffusion of the plasma, which then charge exchanges on the background gas, or is lost to the limiter. Because this is a finite gyro-orbit effect, increasing the plug magnetic field should improve the net beam fueling by reducing this diffusion. Results from the model indicate that increasing the plug midplane field from 2600 to 4000 gauss will improve the beam fueling significantly

  3. Complex anal fistulas: plug or flap?

    Science.gov (United States)

    Muhlmann, Mark D; Hayes, Julian L; Merrie, Arend E H; Parry, Bryan R; Bissett, Ian P

    2011-10-01

    Rectal mucosal advancement flaps (RMAF) and fistula plugs (FP) are techniques used to manage complex anal fistulas. The purpose of this study was to review and compare the results of these methods of repair. A retrospective review of all complex anal fistulas treated by either a RMAF or a FP at Auckland City Hospital from 2004 to 2008. Comparisons were made in terms of successful healing rates, time to failure and the use of magnetic resonance imaging. Overall, 70 operations were performed on 55 patients (55.7% male). The mean age was 44.9 years. Twenty-one patients (30%) had had at least one previous unsuccessful repair. Indications for repair included 57 high cryptoglandular anal (81%), 4 Crohn's anal (6%), 7 rectovaginal (10%), 1 rectourethral (1%) and 1 pouch-vaginal fistula (1%). All patients were followed up with a mean of 4.5 months. Forty-eight RMAFs (69% of total) were performed with 16 successful repairs (33%). Twenty-two FPs (31% of total) were performed with 7 successful repairs (32%, P = 0.9). In failed repairs, there was no difference in terms of mean time to failure (RMAF 4.8 months versus FP 4.1 months, P = 0.62). Magnetic resonance imaging was performed in 21 patients (37%) before the repair. The success rate in these patients was 20%. The results of treatment of complex anal fistulas are disappointing. The choice of operation of either a RMAF or a FP did not alter the poor healing rates of about one third of patients in each group.

  4. Amplatzer vascular plugs in congenital cardiovascular malformations

    Directory of Open Access Journals (Sweden)

    Parag Barwad

    2013-01-01

    Full Text Available Background: Amplatzer vascular plugs (AVPs are devices ideally suited to close medium-to-large vascular communications. There is limited published literature regarding the utility of AVPs in congenital cardiovascular malformations (CCVMs. Aims: To describe the use of AVPs in different CCVMs and to evaluate their safety and efficacy. Materials and Methods: All patients who required an AVP for the closure of CCVM were included in this retrospective review of our catheterization laboratory data. The efficacy and safety of AVPs are reported. Results: A total of 39 AVPs were implanted in 31 patients. Thirteen (33% were AVP type I and 23 (59% were AVP type II. AVP type III were implanted in two patients and type IV in one patient. The major indications for their use included closure of pulmonary arteriovenous malformation (AVM (n = 7, aortopulmonary collaterals (n = 7, closure of a patent Blalock-Taussig shunt (n = 5, systemic AVM (n = 5, coronary AVM (n = 4, patent ductus arteriosus (PDA (n = 3, pulmonary artery aneurysms (n = 3, and venovenous collaterals (n = 2. Deployment of the AVP was done predominantly via the 5 - 7F Judkin′s right coronary guide catheter. Overall 92% of the AVPs could be successfully deployed and resulted in occlusion of the target vessel in all cases, within 10 minutes. No procedure-related or access site complication occurred. Conclusions: AVPs are versatile, easy to use, and effective devices to occlude the vascular communications in a variety of settings. AVP II is especially useful in the closure of tubular structures with a high flow.

  5. Ports Primer: 7.1 Environmental Impacts

    Science.gov (United States)

    Port operations can lead to environmental impacts on air, water and land. Many communities with environmental justice concerns also experience disparities in health outcomes that they attribute to exposure to emissions from port operations.

  6. Ports Primer: 7.0 Environmental Impacts

    Science.gov (United States)

    Port operations can lead to environmental impacts on air, water and land. Many communities with environmental justice concerns also experience disparities in health outcomes that they attribute to exposure to emissions from port operations.

  7. A Comparative Study of Cycle Variability of Laser Plug Ignition vs Classical Spark Plug Ignition in Combustion Engines

    Science.gov (United States)

    Done, Bogdan

    2017-10-01

    Over the past 30 years numerous studies and laboratory experiments have researched the use of laser energy to ignite gas and fuel-air mixtures. The actual implementation of this laser application has still to be fully achieved in a commercial automotive application. Laser Plug Ignition as a replacement for Spark Plug Ignition in the internal combustion engines of automotive vehicles, offers several potential benefits such as extending lean burn capability, reducing the cyclic variability between combustion cycles and decreasing the total amount of ignition costs, and implicitly weight and energy requirements. The paper presents preliminary results of cycle variability study carried on a SI Engine equipped with laser Plug Ignition system. Versus classic ignition system, the use of the laser Plug Ignition system assures the reduction of the combustion process variability, reflected in the lower values of the coefficient of variability evaluated for indicated mean effective pressure, maximum pressure, maximum pressure angle and maximum pressure rise rate. The laser plug ignition system was mounted on an experimental spark ignition engine and tested at the regime of 90% load and 2800 rev/min, at dosage of λ=1.1. Compared to conventional spark plug, laser ignition assures the efficiency at lean dosage.

  8. Single port Billroth I gastrectomy

    Directory of Open Access Journals (Sweden)

    Jeremy R Huddy

    2013-01-01

    Full Text Available Introduction: Experience has allowed increasingly complex procedures to be undertaken by single port surgery. We describe a technique for single port Billroth I gastrectomy with a hand-sewn intracorporeal anastomosis in the resection of a benign tumour diagnosed incidentally on a background of cholelithiasis. Materials and Methods: Single port Billroth I gastrectomy and cholecystectomy was performed using a transumbilical quadport. Flexible tipped camera and straight conventional instruments were used throughout the procedure. The stomach was mobilised including a limited lymph node dissection and resection margins in the proximal antrum and duodenum were divided with a flexible tipped laparoscopic stapler. The lesser curve was reconstructed and an intracorporal hand sewn two layer end-to-end anastomosis was performed using unidirectional barbed sutures. Intraoperative endoscopy confirmed the anastomosis to be patent without leak. Results: Enteral feed was started on the day of surgery, increasing to a full diet by day 6. Analgesic requirements were a patient-controlled analgesia morphine pump for 4 postoperative days and paracetamol for 6 days. There were no postoperative complications and the patient was discharged on the eighth day. Histology confirmed gastric submucosal lipoma. Discussion: As technology improves more complex procedures are possible by single port laparoscopic surgery. In this case, flexible tipped cameras and unidirectional barbed sutures have facilitated an intracorporal hand-sewn two layer end-to-end anastomosis. Experience will allow such techniques to become mainstream.

  9. Port Harcourt Medical Journal: Submissions

    African Journals Online (AJOL)

    Port Harcourt Medical Journal (PMJ) is a general medical journal that will consider any original contribution that advances or illuminates medical science or ... The covering letter must include information on prior or duplicate publication and a statement of financial or other relationships that might lead to a conflict of interest.

  10. Cyber security in ports: Business as usual

    OpenAIRE

    Moerel, Lokke; Dezeure, Freddy

    2017-01-01

    Our paper summarizes the risks and provides concrete and pragmatic proposals to increase substantially the cyber maturity and resilience in the ports by organizing training and awareness raising, fostering cooperation and information exchange both between the stakeholders in the ports and across the ports and integrating the cyber risk into the physical security risk management processes and structures already in place within the ports. This also involves a higher degree of oversight by the P...

  11. COMPARATIVE ANALYSIS OF LEADING PORTS OF LATVIA: COMPETITIVENESS OF LIEPAJA PORT

    Directory of Open Access Journals (Sweden)

    Diāna Līduma

    2015-06-01

    Full Text Available There are 10 operating ports in Latvia and 3 of them – Liepaja, Ventspils and Riga ports are regarded as the leading commercial ports. Role of port operation in the economics of region and country is essential from the point of view of employment and entrepreneurship. This is based with data on investment of operation of Latvian ports in GDP, on average it is assessed to be 5-7% annually. In the context of employment, Liepaja Port gives work to 6.9% of human resources of the city. However, concern about the competitiveness of Liepaja Port influenced by the proximity of more developed competitive ports, technical possibilities of the port and dynamics of freight turnover has occurred in recent years. Therewith in framework of this article in the context of such criteria as location of ports and their technical parameters, volumes of freight, specialization and costs of ports, the operation of leading ports of Latvia is intercompared and analyzed by clarifying whether Liepaja Port is competitive among other ports of Latvia. Opinions of port experts on perspectives of port development and statistical data of ports from 2011-2013 are analyzed within the framework of the article. The aim of the research is to clarify the comparative advantages of ports of Latvia. The research revealed that the provision of competitiveness of Liepaja Port is to be related with application of the available free territories, advantages of location in relation to the Scandinavian market, and the necessity to develop the cooperation among ports of Latvia to offer joint freight acquisition, distributions and unified logistics solution and strengthen the position of ports in the circumstances of international competition.

  12. The Front Steering Launcher Design for the ITER ECRH Upper Port

    International Nuclear Information System (INIS)

    Henderson, M A; Chavan, R; Heidinger, R; Nikkola, P; Ramponi, G; Saibene, G; Sanchez, F; Sauter, O; Serikov, A; Zohm, H

    2005-01-01

    The ECRH ITER upper port antenna's role is to stabilize the neoclassical tearing mode (NTM) on either the q = 2 or 3/2 rational flux surfaces, which requires a narrow current deposition profile (j CD ) over a wide range along the resonance surfaces. The width of j CD should be equivalent to the marginal island width to fully stabilise the NTM. Two antenna concepts are under consideration for the upper port launcher: front steering (FS) and remote steering (RS). The FS launcher decouples the steering and focusing aspects using a two mirror system (one focusing and one steering), achieving a wider steering range and higher current density for NTM stabilisation than required by ITER, offering a threefold increase in NTM stabilization efficiency over the RS launcher. The improved physics performance has motivated the further design study of the FS launcher aiming toward a build to print launcher. The present design is compatible with ≥2.0 MW CW operation and 8 beams per port plug. A frictionless backlashfree system is envisioned for the steering mechanism. An overview of the launcher design, the calculated physics performance and the possibility of using the upper port launcher for extended physics applications (beyond NTM stabilisation) are discussed

  13. Multi-functional use of port areas

    NARCIS (Netherlands)

    Ros, R.; Taneja, P.; Vellinga, T.

    2012-01-01

    The core business of a port is handling vessels and cargo. In addition a landlord Port Authority invests in development of port areas. However, in view of the new trends such as stakeholders interests related to environment and sustainability, it is can be wise to reexamine the business portfolio

  14. Systems theory of interconnected port contact systems

    NARCIS (Netherlands)

    Eberard, D.; Maschke, B.M.; Schaft, A.J. van der

    2005-01-01

    Port-based network modeling of a large class of complex physical systems leads to dynamical systems known as port-Hamiltonian systems. The key ingredient of any port-Hamiltonian system is a power-conserving interconnection structure (mathematically formalized by the geometric notion of a Dirac

  15. 50 CFR 24.12 - Designated ports.

    Science.gov (United States)

    2010-10-01

    ...) The U.S. Department of Agriculture ports at Hilo, Hawaii, and Chicago, Illinois, are designated ports..., Florida Atlanta, Georgia Savannah, Georgia Agana, Guam Hilo, Hawaii Honolulu, Hawaii Wailuku, Maui, Hawaii... Orlando, Florida Honolulu, Hawaii New Orleans, Louisiana Hoboken, New Jersey (Port of New York) Jamaica...

  16. Notch filters for port-Hamiltonian systems

    NARCIS (Netherlands)

    Dirksz, D.A.; Scherpen, J.M.A.; van der Schaft, A.J.; Steinbuch, M.

    2012-01-01

    In this paper a standard notch filter is modeled in the port-Hamiltonian framework. By having such a port-Hamiltonian description it is proven that the notch filter is a passive system. The notch filter can then be interconnected with another (nonlinear) port-Hamiltonian system, while preserving the

  17. Conservative systems with ports on contact manifolds

    NARCIS (Netherlands)

    Eberard, D.; Maschke, B.M.; van der Schaft, Arjan; Piztek, P.

    In this paper we propose an extension of port Hamiltonian systems, called conservative systems with ports, which encompass systems arising from the Irreversible Thermodynamics. Firstly we lift a port Hamiltonian system from its state space manifold to the thermodynamic phase space to a contact

  18. Ports and Terminals : Planning and Functional Design

    NARCIS (Netherlands)

    Groenveld, R.; Velsink, H.

    1993-01-01

    1. Maritime transport, means and commodities 3. Principles of integrated port planning 4. Planning and design of a port's water areas 5. Port terminals - introduction 6. Conventional general cargo terminals 7. Container terminals 8. Oil & liquid gas terminals 9. Dry bulk cargo terminals 10. Fishery

  19. Port-contact systems in bilateral telemanipulation

    NARCIS (Netherlands)

    Secchi, C; Stramigioli, Stefano; Fantuzzi, C.

    2007-01-01

    In this paper we develop one of the first control applications of the recently proposed port-contact framework. We show how it is possible to model and control a bilateral telemanipulation system using port-contact systems and we develop a port-contact impedance controller that allows to impose a

  20. Plug pattern optimization for gamma knife radiosurgery treatment planning

    International Nuclear Information System (INIS)

    Zhang Pengpeng; Wu, Jackie; Dean, David; Xing Lei; Xue Jinyue; Maciunas, Robert; Sibata, Claudio

    2003-01-01

    Purpose: To develop a novel dose optimization algorithm for improving the sparing of critical structures during gamma knife radiosurgery by shaping the plug pattern of each individual shot. Method and Materials: We first use a geometric information (medial axis) aided guided evolutionary simulated annealing (GESA) optimization algorithm to determine the number of shots and isocenter location, size, and weight of each shot. Then we create a plug quality score system that checks the dose contribution to the volume of interest by each plug in the treatment plan. A positive score implies that the corresponding source could be open to improve tumor coverage, whereas a negative score means the source could be blocked for the purpose of sparing normal and critical structures. The plug pattern is then optimized via the GESA algorithm that is integrated with this score system. Weight and position of each shot are also tuned in this procedure. Results: An acoustic tumor case is used to evaluate our algorithm. Compared to the treatment plan generated without plug patterns, adding an optimized plug pattern into the treatment planning process boosts tumor coverage index from 95.1% to 97.2%, reduces RTOG conformity index from 1.279 to 1.167, lowers Paddick's index from 1.34 to 1.20, and trims the critical structure receiving more than 30% maximum dose from 16 mm 3 to 6 mm 3 . Conclusions: Automated GESA-based plug pattern optimization of gamma knife radiosurgery frees the treatment planning team from the manual forward planning procedure and provides an optimal treatment plan

  1. Perancangan Miniatur Traffic Light Dengan Mempergunakan Pengendali Port Paralel

    OpenAIRE

    Eka Wahyudi; Desi Permanasari

    2012-01-01

    Port paralel tentunya sudah tidak asing lagi dalam dunia komputer. Hal tersebut disebabkan karena port paralel merupakan sarana komunikasi yang terdapat pada Personal Computer (PC). Dengan memanfaatkan port tersebut, saat ini komputer juga dapat dipergunakan untuk keperluan pengontrolan/pengendalian rangkaian listrik dengan memanfaatkan port paralel (port printer). Port paralel memiliki kecepatan transfer data yang lebih cepat apabila dibandingkan dengan port serial, maka dari itu port parale...

  2. FASTBUS Snoop Diagnostic Module

    International Nuclear Information System (INIS)

    Walz, H.V.; Downing, R.

    1980-11-01

    Development of the FASTBUS Snoop Module, undertaken as part of the prototype program for the new interlaboratory data bus standard, is described. The Snoop Module resides on a FASTBUS crate segment and provides diagnostic monitoring and testing capability. Communication with a remote host computer is handled independent of FASTBUS through a serial link. The module consists of a high-speed ECL front-end to monitor and single-step FASTBUS cycles, a master-slave interface, and a control microprocessor with serial communication ports. Design details and performance specifications of the prototype module are reported. 9 figures, 1 table

  3. 78 FR 36014 - Deepwater Port License Application: Liberty Natural Gas, LLC, Port Ambrose Deepwater Port

    Science.gov (United States)

    2013-06-14

    ... timeline for processing an application. When MarAd and USCG determine that an application contains the... that Port Ambrose falls within the proposed area of interest for the New York Power Authority Long Island-New York City Offshore Wind Project. This project will be acknowledged and considered in the...

  4. Maintaining and Researching Port Safety: A Case Study of the Port of Kaohsiung

    OpenAIRE

    Tseng, Po-Hsing.; Pilcher, Nick.

    2017-01-01

    Maintaining port safety in full conformity with IMO standards is a requisite for every port and country. To do this, understanding the challenges and human factors involved is key. To date, much research has shed valuable light on these factors and considered how to address them. One aspect that is often noted is that both maintaining port safety and researching port safety presents numerous challenges. This paper considers both these aspects in the context of a case study of port safety in K...

  5. Vaginoscopy in Ewes Utilizing a Laparoscopic Surgical Port Device

    Directory of Open Access Journals (Sweden)

    Jeremiah Easley

    2017-01-01

    Full Text Available Vaginoscopy allows for diagnostic evaluation and treatment of the vaginal vault. A laparoscopic surgical port device and rigid telescope were utilized for serial vaginoscopy in 8 healthy anesthetized ewes. Vaginoscopy examinations were performed in each ewe at days 1, 14, and 28. This technique was well-tolerated and facilitated carbon dioxide vaginal inflation, complete vaginal examination, identification of the cervix, and targeted biopsy collection. No complications were encountered during or following the vaginoscopy procedures. The laparoscopic port device was well-suited to the ewe vulvar size. This technique could be applied to clinical evaluation in ewes for the purposes of examination, biopsy, culture, foreign body removal, and minor surgical procedures.

  6. Hub Status and Indexation of Container Ports

    Directory of Open Access Journals (Sweden)

    Yong-An Park

    2015-06-01

    This study develops two sub-indexes of port classification and capacity, and combines cases of these two sub-indexes into various types in order to find a proper port hub index. The paper demonstrates how different types of port hub index are useful measurements for evaluating outputs and inputs of container ports. In a case analysis we show that the indexes of period variables and lagged variables have more explanatory power with regard to changes of port throughputs and high correlation with inputs.

  7. Report on electric cars and plug-in hybrid cars; Redegoerelse - elbiler og plug-in hybridbiler

    Energy Technology Data Exchange (ETDEWEB)

    Elkjaer Toennesen, A.; Winther, K.; Noerregaard, K. (Teknologisk Institut, Taastrup (Denmark)); Larsen, Esben; Christensen, Linda; Kveiborg, O. (Danmarks Teknologiske Univ., Kgs. Lyngby (DTU) (Denmark))

    2010-04-15

    The Center for Green Transport at the Danish Transport Authority has prepared this statement in order to uncover driving technical aspects, user expectations and needs, and the environmental consequences of using electric and plug-in hybrid cars. An electric car is defined as a car driven by an electric motor that has a battery that can be charged with power from the grid. A plug-in hybrid car is defined as a car that combines gasoline or diesel engine with an electric motor with a battery which can be recharged with power from the grid. From an overall consideration related to the transport sector electric cars and plug-in hybrid cars have the major advantage that negative impacts on environment and climate from traffic can be reduced while the high mobility is maintained. Through an increased use of electric cars and plug-in hybrid cars, the many advantages attached to the car as an individual transportation form is maintained, while CO{sub 2} emissions etc. are reduced. Electric cars and plug-in hybrid cars is one of the technologies that are considered to have particularly great prospects in the medium term when it comes to promoting new technologies in transport. Another advantage of using electric vehicles is the power supply factor. An increased use of electricity in transport will reduce the need for and dependence on fossil fuels in the sector. Both electric cars and plug-in hybrid cars are expected to be used for storage of wind power, a possibility which is hardly available today. The plug-in hybrid car could meet some of the challenges facing the pure electric car, because it also can use conventional fuel. The report presents analyses based on three focus areas: a) Users' needs, expectations and economics in relation to vehicles; b) The technology - and hence the manufacturers' opportunities and challenges; c) Connection to the power grid. (ln)

  8. The Plug-in Concept: Technology and Aesthetics of Change

    Directory of Open Access Journals (Sweden)

    Peter Šenk

    2013-01-01

    Full Text Available The architecture concept of plug-in is based on the duality of the infrastructure system and units or elements connected to it. In the context of megastructures, the concept was most vividly characterised by works of Archigram and Japanese Metabolists in the 1960s and early 1970s. Blurring the boundary between the building and the city, the plug-in concept outgrew architectural boundaries and was slowly transformed into an urbanistic concept.The paper presents the cultural context relevant to contemporaneity, which influenced specific development of the technology-driven concept of plug-in in the British Archigram Group and Japanese Metabolists. Based on the aesthetics of change and incompleteness, which was characterised by similar architectural manifestations despite entirely different cultural backgrounds, the plug-in concept foreshadowed social transformation based on freedom, individualisation and mobility in an utopian manner and held a promise of urban development with adaptability to unpredictable needs and desires of residents, who would become its co-creators with an active approach.Although the revolutionary sixties are quite some time behind, the plug-in concept in its commodified form has become and remained operational and relevant at least on the metaphorical level; in the contemporary space it is evident primarily in urbanism and not as much in its original architectural form.

  9. RCC Plug Repair Thermal Tools for Shuttle Mission Support

    Science.gov (United States)

    Rodriguez, Alvaro C.; Anderson, Brian P.

    2010-01-01

    A thermal math model for the Space Shuttle Reinforced Carbon-Carbon (RCC) Plug Repair was developed to increase the confidence in the repair entry performance and provide a real-time mission support tool. The thermal response of the plug cover plate, local RCC, and metallic attach hardware can be assessed with this model for any location on the wing leading edge. The geometry and spatial location of the thermal mesh also matches the structural mesh which allows for the direct mapping of temperature loads and computation of the thermoelastic stresses. The thermal model was correlated to a full scale plug repair radiant test. To utilize the thermal model for flight analyses, accurate predictions of protuberance heating were required. Wind tunnel testing was performed at CUBRC to characterize the heat flux in both the radial and angular directions. Due to the complexity of the implementation of the protuberance heating, an intermediate program was developed to output the heating per nodal location for all OML surfaces in SINDA format. Three Design Reference Cases (DRC) were evaluated with the correlated plug thermal math model to bound the environments which the plug repair would potentially be used.

  10. Manitoba plug-in hybrid electric vehicle (PHEV) demonstration

    Energy Technology Data Exchange (ETDEWEB)

    Hoemsen, R. [Red River College, Winnipeg, MB (Canada); Parsons, R. [Government of Manitoba, Winnipeg, MB (Canada). Centre for Emerging Renewable Energy

    2010-07-01

    Manitoba has low electricity rates, the highest proportion of renewables, and a legislated commitment to reduce greenhouse gases. However, the province still relies heavily on oil as everyone else. The mix of energy opportunities in Manitoba were highlighted in this presentation, with particular reference to the commercialization of electric vehicles. Several photographs were presented of the Toyota plug-in hybrid vehicle and a plug-in hybrid electric demonstration vehicle. A demonstration project overview was offered that used technology from A123 Systems Inc. The conversion module and vehicle users were profiled. Topics that were presented related to the demonstration project included monitoring; gasoline fuel economy results; fuel economy variability; cold weather operation; cold weather issues; battery upgrade solutions; and highly qualified personnel. It was concluded that in terms of follow-up, there is a need to combine findings of current plug-in hybrid electric vehicle demonstration with those for the new Toyota production plug-in hybrid vehicles. Key next steps for the demonstration are to address cabin heating requirements; better characterizing winter performance; and implementation of IPLC units on all plug-in hybrid electric vehicles for electricity consumption. figs.

  11. Method for preventing plugging of water wells by clay

    Energy Technology Data Exchange (ETDEWEB)

    Blazhkov, V I

    1966-01-01

    A method is suggested for preventing the plugging of water-bearing sands by clay from drilling fluids. It consists in placing a cement plug in the upper nipple above the filter, in order to prevent its plugging during the installation. The drilling mud passes through the rinsing windows and fills the internal void of the filter column, thus preventing further percolation and plugging of the filter during its lowering. When a 2-filter column is lowered, the clay solution is pumped into the interval between the cement plug and the next filter; this is done gradually in proportion to the addition of new pipes. When the drilling mud level lowers in the annular space between the pipes, the mud cake, together with water-saturated sand, passes through the rinsing windows into the pipes and is removed to the surface by airlift or other methods. This procedure is described in detail, discussed for various conditions of well structure, and illustrated by schematic drawings. Its advantage is in the possibility of separate testing and production of all water-bearing zones in the well, and it does not require the use of pure water for well washing.

  12. Design approaches for access plugs in a basalt repository

    International Nuclear Information System (INIS)

    O'Rourke, J.; Allirot, D.; O'Connor, K.

    1982-01-01

    This paper describes research, laboratory testing, and analytical approaches taken toward the development of designs for sealing boreholes, shafts, and tunnels penetrating from ground surface to a deep, mined nuclear waste repository in basalt. A material selection process leading to identification of preferred sealing materials is discussed, and the laboratory testing program to define the geochemical and geotechnical performance of these materials is described. Analysis of the environmental conditions in the Columbia Plateau basalt flows leads to identification of tentative design criteria for plug systems. These design criteria include performance of the plug as a hydraulic barrier and as a radionuclide barrier. An important problem for effective performance of a plug system as a hydraulic barrier is shown to be a potentially disturbed zone surrounding the excavation in the stressed and jointed host rock. An idealized one-dimensional numerical model is described for analyzing the performance of the plug as a barrier to radionuclide transport. The preliminary analyses led to the conclusion that the composition and dimensions of practical candidate plugs can satisfy both hydraulic and radionuclide barrier criteria. Examples of candidate designs are shown for boreholes, shafts, and tunnels. 9 references, 6 figures, 6 tables

  13. Plug-in electric vehicles integrating fluctuating renewable electricity

    Energy Technology Data Exchange (ETDEWEB)

    Dallinger, David

    2013-11-01

    This paper examines a method to model plug-in electric vehicles as part of the power system and presents results for the contribution of plug-in electric vehicles to balance the fluctuating electricity generation of renewable energy sources. The scientific contribution includes: - A novel approach to characterizing fluctuating generation. This allows the detailed comparison of results from energy analysis and is the basis to describe the effect of electricity from renewable energy sources and plug-in electric vehicles on the power system. - The characterization of mobile storage, which includes the description of mobility behavior using probabilities and battery discharging costs. - The introduction of an agent-based simulation approach, coupling energy markets and distributed grids using a price-based mechanism design. - The description of an agent with specific driving behavior, battery discharging costs and optimization algorithm suitable for real plug-in vehicles and simulation models. - A case study for a 2030 scenario describing the contribution of plug-in electric vehicles to balance generation from renewable energy sources in California and Germany.

  14. Analysis of the ITER ECH Upper Port Launcher remote maintenance using virtual reality

    International Nuclear Information System (INIS)

    Elzendoorn, Ben; de Baar, Marco; Chavan, Rene; Goodman, Timothy; Heemskerk, Cock; Heidinger, Roland; Kleefeldt, Klaus; Koning, Jarich; Sanders, Stephen; Spaeh, Peter; Strauss, Dirk; Verhoeven, Toon; Vreede, Fred de

    2009-01-01

    All ITER sub-systems of remote handling (RH) classes 1 and 2 have to be remotely maintainable. The maintenance strategy for these components has to ensure system availability after failure or scheduled maintenance. This paper shows how virtual reality (VR) simulation can be used as a tool to analyze the maintenance process, to predict the mean time to repair and to ensure the RH compatibility of one ITER sub-system, the Upper Port Launcher (UPL) . Special emphasis is put on the development of RH procedures and the identification of tooling requirements. The possibility to simulate RH logistics and repair actions in an early stage of the design process allows for the identification of those maintenance actions that require dedicated tests in the Launcher Handling Test Facility at Karlsruhe. The VR analysis, together with dedicated mock-up tests will demonstrate the RH compatibility of the UPL plug, provide input to the design of the Port Plug maintenance area in the ITER Hot Cell, and support the development of RH maintenance tooling.

  15. A histogram memory plug-in board for IBM-PC based nuclear pulse height analysis applications

    International Nuclear Information System (INIS)

    Behere, Anita; Ghodgaonkar, M.D.

    1989-01-01

    The histogram memory PC plug-in board has 8K x 24 dual ported memory with access from PC as well as from on board data acquisition logic. The arbitration control logic monitors the memory access requests from both the sources and honours them on first come first served basis. The data acquisition logic takes only 840 ns. to perform Read-Modify-Write memory operation. The data acquisition logic incorporates ADC interface logic for connecting to a NIM ADC which is normally housed in a NIM system along with other required front-end processing modules. Two interval timers are provided on the board. One of them provides Live Time/Clock Time counting and the other generates a 200 ms interrupt which is used for live spectrum display. The board is fully supported with system and data processing software developed in Turbo Pascal. (author)

  16. Interaction of clay and concrete plugs - Plugging of 5 m deep hole KA1621G01 at Aespoe

    Energy Technology Data Exchange (ETDEWEB)

    Pusch, Roland [Drawrite AB, Lund (Sweden); Luleaa Technical Univ., Luleaa (Sweden); Ramqvist, Gunnar [Eltekno AB, Figeholm (Sweden)

    2011-11-15

    Sealing of deep boreholes in repository rock is planned to be made by installing dense smectite clay plugs where the rock is low-permeable and casting concrete where the holes intersect water-bearing fracture zones. Such zones have to be stabilized before sealing starts because fragments of rock can otherwise fall off and make it difficult to bring equipment for concrete casting and clay plug units down. These parts of the holes are filled with concrete and clay plugs are then inserted up to the nearest fracture zone where concrete is filled to the required level etc. The role of the concrete in the hole and in the closest part of the surrounding fracture zone is to provide stable parts that are sufficiently fine-porous to prevent clay particles from contacting clay plugs to migrate into the fractures and be lost by erosion. While the larger parts of long clay plugs are believed to stay largely intact chemically for hundreds of thousands of years, the parts adjacent to concrete plugs may undergo changes and so can the concrete plugs themselves. The objective of the presently reported project was to identify the detailed processes and quantify associated changes in physical properties by investigating samples of clay and concrete from a 2.5 m long plug of clay over which an equally long concrete plug had been cast and left to rest for 3 years. The outcome of the investigations was that significant chemically induced changes in mineralogy and physical performance had occurred within a few centimetres distance from the clay/concrete contact but that virtually no changes had taken place at larger distance. A comprehensive laboratory study including X-ray diffraction (XRD), X-ray fluorescence (XRF) and electron microscopy study (SEM and TEM) on the sample material was performed including also dual beam (combined ion and electron) microscopy. It was found that the clay had infiltrated the contacting concrete plug after filling of the borehole since clay was detected both

  17. Interaction of clay and concrete plugs - Plugging of 5 m deep hole KA1621G01 at Aespoe

    International Nuclear Information System (INIS)

    Pusch, Roland; Ramqvist, Gunnar

    2011-11-01

    Sealing of deep boreholes in repository rock is planned to be made by installing dense smectite clay plugs where the rock is low-permeable and casting concrete where the holes intersect water-bearing fracture zones. Such zones have to be stabilized before sealing starts because fragments of rock can otherwise fall off and make it difficult to bring equipment for concrete casting and clay plug units down. These parts of the holes are filled with concrete and clay plugs are then inserted up to the nearest fracture zone where concrete is filled to the required level etc. The role of the concrete in the hole and in the closest part of the surrounding fracture zone is to provide stable parts that are sufficiently fine-porous to prevent clay particles from contacting clay plugs to migrate into the fractures and be lost by erosion. While the larger parts of long clay plugs are believed to stay largely intact chemically for hundreds of thousands of years, the parts adjacent to concrete plugs may undergo changes and so can the concrete plugs themselves. The objective of the presently reported project was to identify the detailed processes and quantify associated changes in physical properties by investigating samples of clay and concrete from a 2.5 m long plug of clay over which an equally long concrete plug had been cast and left to rest for 3 years. The outcome of the investigations was that significant chemically induced changes in mineralogy and physical performance had occurred within a few centimetres distance from the clay/concrete contact but that virtually no changes had taken place at larger distance. A comprehensive laboratory study including X-ray diffraction (XRD), X-ray fluorescence (XRF) and electron microscopy study (SEM and TEM) on the sample material was performed including also dual beam (combined ion and electron) microscopy. It was found that the clay had infiltrated the contacting concrete plug after filling of the borehole since clay was detected both

  18. Device for sealing a rotating plug in a nuclear reactor

    International Nuclear Information System (INIS)

    Brandstetter, R.

    1975-01-01

    The invention relates to the sealing of a rotating plug in a nuclear reactor. The sealing arrangement comprises a friction track which is formed along the periphery of the top of a ring mounted on a stationary element. An annular base coaxial with the plug is secured in sealing-tight manner to the stationary bearing around the ring and the track by means of a seal which rests on the annular base and also on the friction track of the ring and which comprises at least one friction ring and a clamping spring ring. The seal is clamped against the friction track to retractable clamping means when the plug is stationary, the retractable clamping means being carried by a ring secured to the first-mentioned ring. (U.S.)

  19. Revascularization and Apical Plug in an Immature Molar

    Science.gov (United States)

    Roghanizadeh, Leyla; Fazlyab, Mahta

    2018-01-01

    Managing of necrotic permanent teeth with immature apices is a treatment challenges. Treatment of such teeth includes apexification, apical plug and more recently, revascularization technique with the probable advantage of continuation of root development. In the present case report the referred patient had discomfort with a necrotic immature mandibular first molar. Periapical radiography showed a rather large apical lesion around immature roots. Revascularization protocol using calcium-enriched mixture (CEM) cement was indicated for the mesial root. However, in distal canal apical plug technique was applied. At 2-year follow-up, both procedures were successful in relieving patient’s symptoms. Dentin formation and increase in length of the mesial root was obvious. Apical plug and revascularization technique proved to be successful in management of necrotic immature teeth; moreover, revascularization carried the advantage of continuation of root development. PMID:29692851

  20. Flexible Plug Repair for Shuttle Wing Leading Edge

    Science.gov (United States)

    Camarda, Charles J.; Sikora, Joseph; Smith, Russel; Rivers, H.; Scotti, Stephen J.; Fuller, Alan M.; Klacka, Robert; Reinders, Martin; Schwind, Francis; Sullivan, Brian; hide

    2012-01-01

    In response to the Columbia Accident Investigation Board report, a plug repair kit has been developed to enable astronauts to repair the space shuttle's wing leading edge (WLE) during orbit. The plug repair kit consists of several 17.78- cm-diameter carbon/silicon carbide (C/SiC) cover plates of various curvatures that can be attached to the refractory carbon-carbon WLE panels using a TZM refractory metal attach mechanism. The attach mechanism is inserted through the damage in the WLE panel and, as it is tightened, the cover plate flexes to conform to the curvature of the WLE panel within 0.050 mm. An astronaut installs the repair during an extravehicular activity (EVA). After installing the plug repair, edge gaps are checked and the perimeter of the repair is sealed using a proprietary material, developed to fill cracks and small holes in the WLE.

  1. Structural integrity investigations of feeder pipe ice plugging procedures

    International Nuclear Information System (INIS)

    Flaman, M.T.; Shah, N.N.

    1985-03-01

    A procedure involving the use of a liquid nitrogen cooled heat exchanger to form internal ice plugs in feeder pipes is routinely used in nuclear generating stations. The use of this procedure has caused concerns with regard to the safety of station maintenance personnel, and in regard to the integrity of the feeder pipes. This report describes the results of laboratory stress and pressure measurements which were performed on a feeder pipe section during ice plugging operations to investigate these concerns. From the results of this study, and from the results of previous studies of material behaviour at low temperatures, it has been determined that the ice plugging procedure can be performed on feeder pipes in a safe and effective manner

  2. Biannular Airbreathing Nozzle Rig (BANR) facility checkout and plug nozzle performance test data

    Science.gov (United States)

    Cummings, Chase B.

    2010-09-01

    The motivation for development of a supersonic business jet (SSBJ) platform lies in its ability to create a paradigm shift in the speed and reach of commercial, private, and government travel. A full understanding of the performance capabilities of exhaust nozzle configurations intended for use in potential SSBJ propulsion systems is critical to the design of an aircraft of this type. Purdue University's newly operational Biannular Airbreathing Nozzle Rig (BANR) is a highly capable facility devoted to the testing of subscale nozzles of this type. The high accuracy, six-axis force measurement system and complementary mass flowrate measurement capabilities of the BANR facility make it rather ideally suited for exhaust nozzle performance appraisal. Detailed accounts pertaining to methods utilized in the proper checkout of these diagnostic capabilities are contained herein. Efforts to quantify uncertainties associated with critical BANR test measurements are recounted, as well. Results of a second hot-fire test campaign of a subscale Gulfstream Aerospace Corporation (GAC) axisymmetric, shrouded plug nozzle are presented. Determined test article performance parameters (nozzle thrust efficiencies and discharge coefficients) are compared to those of a previous test campaign and numerical simulations of the experimental set-up. Recently acquired data is compared to published findings pertaining to plug nozzle experiments of similar scale and operating range. Suggestions relating to the future advancement and improvement of the BANR facility are provided. Lessons learned with regards to test operations and calibration procedures are divulged in an attempt to aid future facility users, as well.

  3. A small porous-plug burner for studies of combustion chemistry and soot formation

    Science.gov (United States)

    Campbell, M. F.; Schrader, P. E.; Catalano, A. L.; Johansson, K. O.; Bohlin, G. A.; Richards-Henderson, N. K.; Kliewer, C. J.; Michelsen, H. A.

    2017-12-01

    We have developed and built a small porous-plug burner based on the original McKenna burner design. The new burner generates a laminar premixed flat flame for use in studies of combustion chemistry and soot formation. The size is particularly relevant for space-constrained, synchrotron-based X-ray diagnostics. In this paper, we present details of the design, construction, operation, and supporting infrastructure for this burner, including engineering attributes that enable its small size. We also present data for charactering the flames produced by this burner. These data include temperature profiles for three premixed sooting ethylene/air flames (equivalence ratios of 1.5, 1.8, and 2.1); temperatures were recorded using direct one-dimensional coherent Raman imaging. We include calculated temperature profiles, and, for one of these ethylene/air flames, we show the carbon and hydrogen content of heavy hydrocarbon species measured using an aerosol mass spectrometer coupled with vacuum ultraviolet photoionization (VUV-AMS) and soot-volume-fraction measurements obtained using laser-induced incandescence. In addition, we provide calculated mole-fraction profiles of selected gas-phase species and characteristic profiles for seven mass peaks from AMS measurements. Using these experimental and calculated results, we discuss the differences between standard McKenna burners and the new miniature porous-plug burner introduced here.

  4. Mechanical design and thermo-hydraulic simulation of the infrared thermography diagnostic of the WEST tokamak

    Energy Technology Data Exchange (ETDEWEB)

    Micolon, Frédéric, E-mail: frederic.micolon@cea.fr; Courtois, Xavier; Aumeunier, Marie-Hélène; Chenevois, Jean-Pierre; Larroque, Sébastien

    2015-10-15

    The WEST (Tungsten (W) Environment in Steady state Tokamak) project is a partial rebuild of the Tore Supra tokamak to make it an X-point metallic environment machine aimed at testing ITER technologies in relevant plasma environment. For the safe operation of the WEST tokamak, infra-red (IR) thermography is a crucial diagnostic as it is a sound and reliable way to detect hotspots or abnormal heating patterns on the plasma facing components (PFCs). Thus WEST will be fitted with middle/short-IR (1.5–2 μm or 3–5 μm) cameras in the upper port plugs to get a full view of the critical PFCs (in particular the new lower divertor) and radio-frequency (RF) heating antennas and one camera at the equatorial level to monitor the new upper divertor and the first wall. This paper describes the design of the up-to-date optical system along with the hydraulic analysis and the thermal and mechanical finite element analysis conducted to ensure adequate heat extraction capabilities. Boundary conditions and simulation results will be presented and discussed as well as technological solutions retained.

  5. Determinants of Port Performance - Case Study of 4 Main Ports in Indonesia (2005-2015

    Directory of Open Access Journals (Sweden)

    Atika Aqmarina

    2018-03-01

    Full Text Available Port plays significant role in supporting economic growth of a country. This study aims to analyze the determinant of port performance in Indonesia. In this research, the ports selected are four main ports in Indonesia which are Port of Belawan, Port of Tanjung Priok, Port of Tanjung Perak, and Makassar. These ports are designed as the hub ports in the national sea transport system of the country. The study used pooled OLS as the methodology to analyze the determinant. The result of this studies shows that total traffic is not influenced by operating surplus per ton, whereas the rest of variables such as turnaround time, idle time, berth of occupancy rate, rate of return, number of employee and cargo equipment have significant results and significantly influenced the total traffic.

  6. Plug and Play PV Systems for American Homes

    Energy Technology Data Exchange (ETDEWEB)

    Hoepfner, Christian [Fraunhofer USA, Inc., Boston, MA (United States)

    2016-12-22

    The core objectives of the Plug & Play PV Systems Project were to develop a PV system that can be installed on a residential rooftop for less than $1.50/W in 2020, and in less than 10 hours (from point of purchase to commissioning). The Fraunhofer CSE team’s approach to this challenge involved a holistic approach to system design – hardware and software – that make Plug & Play PV systems: • Quick, easy, and safe to install • Easy to demonstrate as code compliant • Permitted, inspected, and interconnected via an electronic process Throughout the three years of work during this Department of Energy SunShot funded project, the team engaged in a substantive way with inspectional services departments and utilities, manufacturers, installers, and distributors. We received iterative feedback on the system design and on ideas for how such systems can be commercialized. This ultimately led us to conceiving of Plug & Play PV Systems as a framework, with a variety of components compatible with the Plug & Play PV approach, including string or microinverters, conventional modules or emerging lightweight modules. The framework enables a broad group of manufacturers to participate in taking Plug & Play PV Systems to market, and increases the market size for such systems. Key aspects of the development effort centered on the system hardware and associated engineering work, the development of a Plug & Play PV Server to enable the electronic permitting, inspection and interconnection process, understanding the details of code compliance and, on occasion, supporting applications for modifications to the code to allow lightweight modules, for example. We have published a number of papers on our testing and assessment of novel technologies (e.g., adhered lightweight modules) and on the electronic architecture.

  7. Experimental and numerical modeling of sulfur plugging in carbonate reservoirs

    Energy Technology Data Exchange (ETDEWEB)

    Abou-Kassem, J.H. [Chemical and Petroleum Engineering Department, UAE University, PO Box 17555, Al-Ain (United Arab Emirates)

    2000-05-01

    Sour gas, mainly in the form of hydrogen sulfide, is produced in large amounts from many oil and gas reservoirs in the United Arab Emirates. In addition to creating problems in production lines, the precipitation of elemental sulfur in vicinity of the wellbore is often reported to cause wellbore damage. While there have been several studies performed on the role of solid deposition in gas reservoirs, the role of sulfur deposition in oil reservoirs has not been investigated. This paper presents experimental results along with a comprehensive wellbore model that predicts sulfur precipitation as well as plugging. Two separate sets of experiments, one for a gas phase system and another for a crude oil system, were conducted to investigate the deposition of elemental sulfur in (linear) carbonate cores. The gas flow tests were conducted with elemental sulfur being carried with nitrogen through limestone cores. Changes in gas flow rate were monitored while the injection pressure was held constant. A series of experiments generated valuable data for plugging with elemental sulfur. X-ray diffraction tests provided evidence of sulfur deposition along the cores. The oil flow tests were carried out to observe sulfur precipitation and plugging in a carbonate core. The crude oil was de-asphalted before conducting these tests in order to isolate the effect of asphaltene plugging. Significant plugging was observed and was found to be dependent on flow rate and initial sulfur concentration. This information was used in a phenomenological model that was incorporated in the wellbore numerical model. The data for the numerical model were obtained from both test tube and oil flow experiments. By using a phenomenological model, the wellbore plugging was modeled with an excellent match (with experimental results)

  8. MFTF-α+T end plug magnet design

    International Nuclear Information System (INIS)

    Srivastava, V.C.; O'Toole, J.A.

    1983-01-01

    The conceptual design of the end-plug magnets for MFTF-α+T is described. MFTF-α+ T is a near-term upgrade of MFTF-B, which features new end plugs to improve performance. The Fusion Engineering Design Center has performed the engineering design of MFTF-α+T under the overall direction of Lawrence Livermore National Laboratory. Each end plug consists of two Yin-Yang pairs, each with approx.2.5:1 mirror ratio and approx.5-T peak field on axis; two transition coils; and a recircularizing solenoid. This paper describes the end-plug magnet system functional requirements and presents a conceptual design that meets them. The peak field at the windings of the end-plug coils is approx.6-T. These coils are designed using the NbTi MFTF-B conductor and cooled by a 4.2K liquid helium bath. All the end-plug magnets are designed to operate in the cryostable mode with adequate quench protection for safety. Shielding requirements are stated and a summary of heat loads is provided. Field and force calculations are discussed. The field on axis is shown to meet the functional requirements. Force resultants are reported in terms of winding running loads and resultant coil forces are also given. The magnet structural support is described. A trade study to determine the optimum end-cell coil internal nuclear shield thickness and the resulting coil size based on minimizing the end-cell life cycle cost is summarized

  9. Versatile Friction Stir Welding/Friction Plug Welding System

    Science.gov (United States)

    Carter, Robert

    2006-01-01

    A proposed system of tooling, machinery, and control equipment would be capable of performing any of several friction stir welding (FSW) and friction plug welding (FPW) operations. These operations would include the following: Basic FSW; FSW with automated manipulation of the length of the pin tool in real time [the so-called auto-adjustable pin-tool (APT) capability]; Self-reacting FSW (SRFSW); SR-FSW with APT capability and/or real-time adjustment of the distance between the front and back shoulders; and Friction plug welding (FPW) [more specifically, friction push plug welding] or friction pull plug welding (FPPW) to close out the keyhole of, or to repair, an FSW or SR-FSW weld. Prior FSW and FPW systems have been capable of performing one or two of these operations, but none has thus far been capable of performing all of them. The proposed system would include a common tool that would have APT capability for both basic FSW and SR-FSW. Such a tool was described in Tool for Two Types of Friction Stir Welding (MFS- 31647-1), NASA Tech Briefs, Vol. 30, No. 10 (October 2006), page 70. Going beyond what was reported in the cited previous article, the common tool could be used in conjunction with a plug welding head to perform FPW or FPPW. Alternatively, the plug welding head could be integrated, along with the common tool, into a FSW head that would be capable of all of the aforementioned FSW and FPW operations. Any FSW or FPW operation could be performed under any combination of position and/or force control.

  10. Plug the socket of the main closing valve in a nuclear power plant

    International Nuclear Information System (INIS)

    Neupauer, J.; Bednar, B.

    1988-01-01

    The plug is designed for closing the main closing valve socket during a refuelling shutdown of a nuclear power plant. The plug is fixed in the using jaws forced against the socket ring part. The socket is sealed by expanding a ring between two cone trays. A valve provided in the plug allows draining the pipe. The plug is inserted in the socket using a jib suspended on a rail. Following sealing both sockets the inner surfaces of the closing valve can be decontaminated. Following decontamination, a water-proof cover is slid over the plug protecting the plug moving mechanism from damage. (J.B.). 1 fig

  11. Development of a Plug-and-Play Monitoring System for Cabled Observatories in the East China Sea

    Directory of Open Access Journals (Sweden)

    Yang Yu

    2015-07-01

    Full Text Available Seafloor observatories enable long term, continuous and multidisciplinary observations, promising major breakthroughs in marine environment research. The effort to remotely control in situ multidisciplinary equipment performing individual and cooperative tasks is both a challenge and a guarantee for the stable operations of functional observatories. With China starting to establish ocean observatory sensor networks, in this study we describe a monitoring system for cabled observatories in the East China Sea (ESOMS that enables this effort in a plug and play way. An information oriented monitoring architecture for ESOMS was first introduced, derived from a layered control model for ocean observatory sensor network. The architecture contained three components and enabled bidirectional information flow of observation data and commands, based on which architecture components were designed to enable plug-and-play control within related model layers. A control method enabled by general junction box (GJB and ocean sensor markup language (OSML was thus proposed as the plug-and-play solution for implementing ESOMS. The GJB-OSML enabled control method (GOE Control Method mainly actualized two processes, one of which was that the in situ GJB interfaced and represented every attached sensor as a Sensing Endpoint in the cabled observatory network. The other process was that the remote ESOMS utilized the same IP/Port related information modeled by OSML to create/operate a Function Node acted as agent of the in situ sensor. A case study for using ESOMS in the Xiaoqushan Seafloor Observatory was finally presented to prove its performance and applicability. Given this successful engineering trial, the ESOMS design and implementation could be applicable and beneficial for similar efforts in future construction of seafloor observatory network both at home and abroad.

  12. Warning: safety risk with some Apple AC Wall Plug Adapters

    CERN Multimedia

    CERN IT department

    2016-01-01

    Dear Mac and iOS Users, Apple has determined that some of its two prong Apple AC wall plug adapters may break and create a risk of electrical shock.   CERN users can now exchange their affected Apple wall plug adapters at the Service Desk. To find out if your adapter is affected and for any further information concerning the procedure to follow to exchange it, please check the following URL: https://cern.service-now.com/service-portal/view-outage.do?n=OTG0028639.

  13. Modeling and Validation of Sodium Plugging for Heat Exchangers in Sodium-cooled Fast Reactor Systems

    Energy Technology Data Exchange (ETDEWEB)

    Ferroni, Paolo [Westinghouse Electric Company LLC, Cranberry Township, PA (United States). Global Technology Development; Tatli, Emre [Westinghouse Electric Company LLC, Cranberry Township, PA (United States); Czerniak, Luke [Westinghouse Electric Company LLC, Cranberry Township, PA (United States); Sienicki, James J. [Argonne National Lab. (ANL), Argonne, IL (United States); Chien, Hual-Te [Argonne National Lab. (ANL), Argonne, IL (United States); Yoichi, Momozaki [Argonne National Lab. (ANL), Argonne, IL (United States); Bakhtiari, Sasan [Argonne National Lab. (ANL), Argonne, IL (United States)

    2016-06-29

    section and provided with Na2O deposition prediction capabilities, was developed. This state-of-the-art computational tool incorporates a first-principles Na2O deposition model developed by ANL, and combines it with predictive capabilities for the spatial and temporal variation of temperature, velocity, dissolved oxygen concentration, and wall temperature under flowing sodium conditions. The CFD model was validated under no-deposition conditions using experimental data collected with the SPPL, demonstrating the model’s capability to predict the thermal-hydraulics of the SPPL test section within the measurement uncertainty characterizing the SPPL instrumentation. The model’s deposition prediction capability was not, however, validated as the SPPL could not be operated under plugging conditions during the project, resulting in the lack of deposition data with adequate pedigree for a CFD model validation. Two novel diagnostic techniques to detect and characterize Na2O deposits, i.e. Ultrasonic Time Domain Reflectometry (UTDR) and Potential Drop (PD) techniques, were developed to ultimately assist in the validation effort under plugging conditions, which can be performed once the SPPL becomes operational. This development effort consisted first in demonstrating, analytically and/or computationally, the capability of these techniques to diagnose Na2O deposits inside of small channels (particularly the deposit’s thickness), and subsequently in the fabrication and testing of prototypical UTDR and PD instrumentation. The testing, performed on mockups of the SPPL test section, demonstrated the capability of these techniques to detect and characterize material discontinuities like those induced by sodium oxide deposition on stainless steel channel walls. Because of the mentioned impossibility to run the SPPL in a plugging mode, the developed instrumentation could not be tested in-situ, i.e. at the SPPL while deposits are being

  14. Plug-in Based Analysis Framework for LHC Post-Mortem Analysis

    CERN Document Server

    Gorbonosov, R; Zerlauth, M; Baggiolini, V

    2014-01-01

    Plug-in based software architectures [1] are extensible, enforce modularity and allow several teams to work in parallel. But they have certain technical and organizational challenges, which we discuss in this paper. We gained our experience when developing the Post-Mortem Analysis (PMA) system, which is a mission critical system for the Large Hadron Collider (LHC). We used a plugin-based architecture with a general-purpose analysis engine, for which physicists and equipment experts code plugins containing the analysis algorithms. We have over 45 analysis plugins developed by a dozen of domain experts. This paper focuses on the design challenges we faced in order to mitigate the risks of executing third-party code: assurance that even a badly written plugin doesn't perturb the work of the overall application; plugin execution control which allows to detect plugin misbehaviour and react; robust communication mechanism between plugins, diagnostics facilitation in case of plugin failure; testing of the plugins be...

  15. Skeletal scintigraphic appearance of an auto-transplanted osteoarticular plug: epiphyseal transplant

    International Nuclear Information System (INIS)

    Morrison, Stuart C.; O'Donnell, James; Makley, John T.

    2003-01-01

    Nuclear medicine bone scan is an essential diagnostic imaging tool both for the diagnosis and staging of bone tumors and in the follow-up of these patients. It is very important that we be able to discriminate between normal variants, changes related to altered physical stress, and recurrent disease in order to interpret the bone scan meaningfully. We wish to report the appearance of the isotope bone scan, technetium 99m-labeled methylene diphosphonate ( 99m Tc-MDP), associated with an auto-transplanted osteoarticular plug (epiphyseal transplant) performed following limb amputation. This reconstructive surgery can give a potentially misleading appearance on the nuclear medicine bone scan if one is unfamiliar with this surgical technique. (orig.)

  16. Skeletal scintigraphic appearance of an auto-transplanted osteoarticular plug: epiphyseal transplant

    Energy Technology Data Exchange (ETDEWEB)

    Morrison, Stuart C.; O' Donnell, James [University Hospitals Cleveland, Department of Radiology-Hb6, Department of Radiology-Hb6, 9500 Euclid Avenue, OH 44195, Cleveland (United States); Makley, John T. [University Hospitals Cleveland, Department of Orthopedic Surgery, The Cleveland Clinic Children' s Hospital, 9500 Euclid Avenue, OH 44195, Cleveland (United States)

    2003-07-01

    Nuclear medicine bone scan is an essential diagnostic imaging tool both for the diagnosis and staging of bone tumors and in the follow-up of these patients. It is very important that we be able to discriminate between normal variants, changes related to altered physical stress, and recurrent disease in order to interpret the bone scan meaningfully. We wish to report the appearance of the isotope bone scan, technetium 99m-labeled methylene diphosphonate ({sup 99m}Tc-MDP), associated with an auto-transplanted osteoarticular plug (epiphyseal transplant) performed following limb amputation. This reconstructive surgery can give a potentially misleading appearance on the nuclear medicine bone scan if one is unfamiliar with this surgical technique. (orig.)

  17. Congenital anomalous/aberrant systemic artery to pulmonary venous fistula: Closure with vascular plugs & coil embolization

    Directory of Open Access Journals (Sweden)

    Pankaj Jariwala

    2014-01-01

    Full Text Available A 7-month-old girl with failure to thrive, who, on clinical and diagnostic evaluation [echocardiography & CT angiography] to rule out congenital heart disease, revealed a rare vascular anomaly called systemic artery to pulmonary venous fistula. In our case, there was dual abnormal supply to the entire left lung as1 anomalous supply by normal systemic artery [internal mammary artery]2 and an aberrant feeder vessel from the abdominal aorta. Left Lung had normal bronchial connections and normal pulmonary vasculature. The fistula drained through the pulmonary veins to the left atrium leading to ‘left–left shunt’. Percutaneous intervention in two stages was performed using Amplatzer vascular plugs and coil embolization to close them successfully. The patient gained significant weight in follow up with other normal developmental and mental milestones.

  18. COMPETITION BETWEEN CONTAINER PORTS IN THE NORTHERN ADRIATIC

    OpenAIRE

    Elen Twrdy; Milan Batista

    2014-01-01

    World trade has changed in the last decade such that container traffic flows are oriented towards more parts of the European continent. The European container port system is not a homogeneous set of ports; instead it consists of several big ports (e.g., Rotterdam, Hamburg, Algeciras...) and a large number of medium and small ports. Northern Adriatic (NA) ports, namely Rijeka, Koper, Trieste, Venice and Ravenna, are small ports. Each of these ports have different development plans but in varyi...

  19. Conceptual & Engineering Design of Plug-in Cryostat Cylinder for Super-Conducting Central Solenoid of SST-1

    Science.gov (United States)

    Biswas, Prabal; Santra, Prosenjit; Vasava, Kirit; Jayswal, Snehal; Parekh, Tejas; Chauhan, Pradeep; Patel, Hitesh; Pradhan, Subrata

    2017-04-01

    SST-1, country’s first indigenously built steady state super-conducting tokamak is planned to be equipped with an Nb3Sn based superconducting central solenoid, which will replace the existing copper conductor TR1 coil for the purpose of Ohmic breakdown. This central solenoid (CS) of four layers with each layer having 144 turns with an OD of 573 mm, ID of 423 mm length of 2483 mm will be housed inside a high vacuum, CRYO compatible plug-in cryostat thin shell having formed from SS 304L plate duly rolled and welded to form cylinder along with necessary accessories like LN2 bubble panel, current lead chamber, coil and cylinder support structure etc. This paper will present the design drivers, material selection, advantages and constraints of the plug-in cryostat concept, sub-systems of plug-in cryostat, its conceptual and engineering design, CAD models, finite element analysis using ANSYS, safety issues and diagnostics, on-going works about fabrication, quality assurance/control and assembly/integration aspects with in the existing SST-1 machine bore.

  20. The Challenges of Malaysian Dry Ports Development

    Directory of Open Access Journals (Sweden)

    Jagan Jeevan

    2015-03-01

    Full Text Available This paper examines the functions and challenges of dry ports development in Malaysia through 11 face-to-face interviews with dry port stakeholders. The findings reveal that Malaysian dry ports are developed to accelerate national and international business, to activate intermodalism in the nation, to promote regional economic development and to enhance seaport competitiveness. Malaysian dry ports perform the function of transport and logistics, information processing, seaports and value-added services. Challenges facing Malaysian dry ports include insufficient railway tracks, unorganized container planning on the rail deck, highly dependent on single mode of transportation, poor recognition from the seaport community, and competition from localized seaports. This paper further indicates strategies for coping with these challenges and identifies future opportunities for Malaysian dry ports development.

  1. Plug-In Electric Vehicle Handbook for Consumers (Brochure)

    Energy Technology Data Exchange (ETDEWEB)

    2011-09-01

    Plug-in electric vehicles (PEVs) are entering the automobile market and are viable alternatives to conventional vehicles. This guide for consumers describes the basics of PEV technology, PEV benefits, how to select the right PEV, charging a PEV, and PEV maintenance.

  2. Alternative Fuels Data Center: Plug-In Hybrid Electric Vehicles

    Science.gov (United States)

    . Fueling and Driving Options Plug-in hybrid electric vehicle batteries can be charged by an outside sized hybrid electric vehicle. If the vehicle is driven a shorter distance than its all-electric range drives the wheels almost all of the time, but the vehicle can switch to work like a parallel hybrid at

  3. Biodegradable microfabricated plug-filters for glaucoma drainage devices.

    Science.gov (United States)

    Maleki, Teimour; Chitnis, Girish; Park, Jun Hyeong; Cantor, Louis B; Ziaie, Babak

    2012-06-01

    We report on the development of a batch fabricated biodegradable truncated-cone-shaped plug filter to overcome the postoperative hypotony in nonvalved glaucoma drainage devices. Plug filters are composed of biodegradable polymers that disappear once wound healing and bleb formation has progressed past the stage where hypotony from overfiltration may cause complications in the human eye. The biodegradable nature of device eliminates the risks associated with permanent valves that may become blocked or influence the aqueous fluid flow rate in the long term. The plug-filter geometry simplifies its integration with commercial shunts. Aqueous humor outflow regulation is achieved by controlling the diameter of a laser-drilled through-hole. The batch compatible fabrication involves a modified SU-8 molding to achieve truncated-cone-shaped pillars, polydimethylsiloxane micromolding, and hot embossing of biodegradable polymers. The developed plug filter is 500 μm long with base and apex plane diameters of 500 and 300 μm, respectively, and incorporates a laser-drilled through-hole with 44-μm effective diameter in the center.

  4. Height suppression of tomato plug seedlings by an environment ...

    African Journals Online (AJOL)

    Experiments were conducted to investigate appropriate concentrations of plant growth retardants (PGRs) and duration of seed soaking in order to suppress hypocotyl length and plug seedling height of 2 tomato cultivars ( Lycopersicum esculentum Mill. cv. Seogeon and Seokwang). Daminozide (B-9), uniconazole ...

  5. Project Gasbuggy well plugging and site restoration plan

    International Nuclear Information System (INIS)

    1978-07-01

    The operational plan for conducting the final restoration work at the site of the first U.S. underground nuclear experiment for the stimulation of low-productivity natural gas reservoirs is given. The plan includes well plugging procedures, surface facilities decontamination and removal procedures, radiological guidelines, and environmental considerations

  6. End plug welding of nuclear fuel elements-AFFF experience

    International Nuclear Information System (INIS)

    Bhatt, R.B.; Singh, S.; Aniruddha Kumar; Amit; Arun Kumar; Panakkal, J.P.; Kamath, H.S.

    2004-01-01

    Advanced Fuel Fabrication Facility is engaged in the fabrication of mixed oxide (U,Pu)O 2 fuel elements of various types of nuclear reactors. Fabrication of fuel elements involves pellet fabrication, stack making, stack loading and end plug welding. The requirement of helium bonding gas inside the fuel elements necessitates the top end plug welding to be carried out with helium as the shielding gas. The severity of the service conditions inside a nuclear reactor imposes strict quality control criteria, which demands for almost defect free welds. The top end plug welding being the last process step in fuel element fabrication, any rejection at this stage would lead to loss of effort prior to this step. Moreover, the job becomes all the more difficult with mixed oxide (MOX) as the entire fabrication work has to be carried out in glove box trains. In the case of weld rejection, accepted pellets are salvaged by cutting the clad tube. This is a difficult task and recovery of pellets is low (requiring scrap recovery operation) and also leads to active metallic waste generation. This paper discusses the experience gained at AFFF, in the past 12 years in the area of end plug welding for different types of MOX fuel elements

  7. Plug-In Electric Vehicle Handbook for Fleet Managers (Brochure)

    Energy Technology Data Exchange (ETDEWEB)

    2012-04-01

    Plug-in electric vehicles (PEVs) are entering the automobile market and are viable alternatives to conventional vehicles. This guide for fleet managers describes the basics of PEV technology, PEV benefits for fleets, how to select the right PEV, charging a PEV, and PEV maintenance.

  8. Axicell design for the end plugs of MFTF-B

    International Nuclear Information System (INIS)

    Thomassen, K.I.; Karpenko, V.N.

    1982-01-01

    Certain changes in the end-plug design in the Mirror Fusion Test Facility (MFTF-B) are described. The Laboratory (LLNL) proposes to implement these changes as soon as possible in order to construct the machine in an axicell configuration. The present physics and technology goals as well as the project cost and schedule will not be affected by these changes

  9. Nuclear determination of saturation profiles in core plugs

    International Nuclear Information System (INIS)

    Sletsgaard, J.; Oelgaard, P.L.

    1997-01-01

    A method to determine liquid saturations in core plugs during flooding is of importance when the relative permeability and capillary pressure function are to be determined. This part of the EFP-95 project uses transmission of γ-radiation to determine these saturations. In γ-transmission measurements, the electron density of the given substance is measured. This is an advantage as compared to methods that use electric conductivity, since neither oil nor gas conducts electricity. At the moment a single 137 Cs-source is used, but a theoretical investigation of whether it is possible to determine three saturations, using two radioactive sources with different γ-energies, has been performed. Measurements were made on three core plugs. To make sure that the measurements could be reproduced, all the plugs had a point of reference, i.e. a mark so that it was possible to place the plug same way every time. Two computer programs for calculation of saturation and porosity and the experimental setup are listed. (EG)

  10. Valley plugs, land use, and phytogeomorphic response: Chapter 14

    Science.gov (United States)

    Pierce, Aaron R.; King, Sammy L.; Shroder, John F.

    2013-01-01

    Anthropogenic alteration of fluvial systems can disrupt functional processes that provide valuable ecosystem services. Channelization alters fluvial parameters and the connectivity of river channels to their floodplains which is critical for productivity, nutrient cycling, flood control, and biodiversity. The effects of channelization can be exacerbated by local geology and land-use activities, resulting in dramatic geomorphic readjustments including the formation of valley plugs. Considerable variation in the response of abiotic processes, including surface hydrology, subsurface hydrology, and sedimentation dynamics, to channelization and the formation of valley plugs. Altered abiotic processes associated with these geomorphic features and readjustments influence biotic processes including species composition, abundance, and successional processes. Considerable interest exists for restoring altered fluvial systems and their floodplains because of their social and ecological importance. Understanding abiotic and biotic responses of channelization and valley-plug formation within the context of the watershed is essential to successful restoration. This chapter focuses on the primary causes of valley-plug formation, resulting fluvial-geomorphic responses, vegetation responses, and restoration and research needs for these systems.

  11. A Rotating Plug Model of Friction Stir Welding Heat Transfer

    Science.gov (United States)

    Raghulapadu J. K.; Peddieson, J.; Buchanan, G. R.; Nunes, A. C.

    2006-01-01

    A simplified rotating plug model is employed to study the heat transfer phenomena associated with the fiction stir welding process. An approximate analytical solution is obtained based on this idealized model and used both to demonstrate the qualitative influence of process parameters on predictions and to estimate temperatures produced in typical fiction stir welding situations.

  12. Choosing Wisely When It Comes to Eye Care: Punctal Plugs for Dry Eye

    Science.gov (United States)

    ... of Our 5-Part Series: Punctal Plugs for Dry Eye Making healthy lifestyle choices can help you protect ... discuss each item in detail. Punctal Plugs for Dry Eye Dry eye is a condition that millions of ...

  13. Instrumentation development for the Waste Isolation Pilot Plant (WIPP) borehole plugging program (BHP)

    International Nuclear Information System (INIS)

    Cook, C.W.

    1979-11-01

    This report discusses the instrumentation development needs of the borehole testing program as it now exists. Although requirements may change as the program progresses, the items indicated are basic to any borehole plugging program. Instrumentation is discussed both for the plug environment and for the plug itself. For the plug environment, a probe for measuring the disturbed region and a coordinate logging tool are required. For the plug itself, instrumentation includes measurements above, within, and below the plug. Instrumentation for most measurements above the plug is currently available; for measurements within and below the plug, however, further development is required. Specifically, resistivity, induction, and acoustic probes; an in situ stressmeter; and a hardwire, feedthrough system need to be developed

  14. Process and device for extracting a cylindrical element such a plug of a small diameter tube

    International Nuclear Information System (INIS)

    Ferlay, J.C.; Gente, D.; Jouin, D.

    1992-01-01

    The plug engaged in a steam generator tube is extracted by first machining away the expander and a part of its side wall then pulling the remainder of the plug from the tube with a tool engaging its closed end

  15. Port pricing : principles, structure and models

    OpenAIRE

    Meersman, Hilde; Strandenes, Siri Pettersen; Van de Voorde, Eddy

    2014-01-01

    Price level and price transparency are input to shippers’ choice of supply chain and transport mode. In this paper, we analyse current port pricing structures in the light of the pricing literature and consider opportunities for improvement. We present a detailed overview of pricing criteria, who sets prices and who ultimately foots the bill for port-of-call charges, cargo-handling fees and congestion charges. Current port pricing practice is based on a rather linear structure and fails to in...

  16. Efficiency analysis of container ports and terminals

    OpenAIRE

    Liu, Q.

    2010-01-01

    In the past two decades the steady growth of seaborne trade has resulted in the increase of container ships, container ports and their terminals. The structure of the shipping market is, moreover, continuously evolving. On the carrier side, shipping companies form consortia and alliances; on the port side, global terminal operators and dedicated container terminals are emerging. The aim of this research is to evaluate the efficiency of container ports and terminals and to study...

  17. Port Sunlight, essai architectural et social

    OpenAIRE

    Machet, Laurence

    2017-01-01

    The purpose of this article is to examine the city of Port Sunlight, its history, design and originality. Created by William Lever in 1888 in order to house his newly-built soap factory, Port Sunlight is part of the numerous “factory villages” built in the wake of the industrial revolution according to philanthropic and utilitarian principles. But this article intends to show that Port Sunlight differs from other factory towns. Its careful design, elaborate architecture and public facilities ...

  18. PORT SECURITY-Threats and Vulnerabilities

    OpenAIRE

    Kusi, Bernard

    2015-01-01

    The main objective of this thesis is to identify the threats and the vulnerabilities concerning Takoradi port, and finally recommend measure to overcome the identified threats and vul-nerabilities. Various categories of potential threats and vulnerabilities have been studied throughout the literature review. However, because each port presents a unique sets of threats and vulnerabilities, there was a need to look critically into how Takoradi port operations are being conducted in other to ide...

  19. Maximizing port and transportation system productivity by exploring alternative port operation strategies.

    Science.gov (United States)

    2011-06-01

    Seaports are a critical transportation component that supports the nations economy. Many U.S. : ports are now experiencing significant truck congestion at the gate, which decreases the productivity of : ports and truck fleets (e.g. truck wait time...

  20. US Army Corps of Engineers Ports, Geographic WGS84, BTS (2006) [usace_port_BTS_2006

    Data.gov (United States)

    Louisiana Geographic Information Center — Contains physical information on commercial facilities at the principal U.S. Coastal, Great Lakes and Inland Ports. The data consists of listings of port area's...

  1. THE Port - hackathon at CERN

    CERN Multimedia

    CERN. Geneva; KNAEPPER, Ines; SILVA DE SOUSA, Bruno

    2014-01-01

    THE Port association combines creative minds from CERN and non-profit organisations in interdisciplinary teams to work on humanitarian technology related benefits to society. Our interdisciplinary teams of handpicked individuals chosen for their field-leading expertise and innovative mind combine humanitarian questions with state of the art science, cutting-edge technology and endless fantasy. We aim to impact the future by fusion of today’s real life problems analysis and vision of scientific evolution of the next decades. This forces us to develop concepts and solutions for the future - hungry to use our expertise in challenges of new fields.

  2. Port virtual addressing for PC

    International Nuclear Information System (INIS)

    Bolanos, L.; Arista, E.; Osorio Deliz, J.F.

    1997-01-01

    Instruments for nuclear signal measurements based on add-on card for a personal computer (PC) are designed often. Then one faces the problem of the addressing of data input/output devices which show an integration level or intelligence that makes the use of several port address indispensable, and these are limited in the PC. The virtual addressing offers the advantage of the occupation of few addresses to accede to many of these devices. The principles of this technique and the appliances of a solution in radiometric in a radiometric card based on programmed logic are discussed in this paper

  3. POLICY PORT IN LATIN AMERICA

    Directory of Open Access Journals (Sweden)

    María Victoria Flores

    2012-07-01

    Full Text Available This work achieves a contextual approach the port services market in Latin America, from the document review the legal framework and jurisprudence. It observes and evaluates the phenomenon under study, establishing a correlation between the grant in the shape of the free supply and demand for services and operating in a market of few suppliers, resulting in national legislation and concession contracts defending a free market and on the other hand, case law on market practice indicating that there is no free market to defend.

  4. Fiscal Year 1993 Well Plugging and Abandonment Program Summary Report Y-12 Plant, Oak Ridge, Tennessee

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1994-09-01

    This report is a synopsis of the progress of the well plugging and abandonment program at the Y-12 Plant, Oak Ridge, Tennessee, from October 1993 through August 1994. A total of 57 wells and borings were plugged and abandoned during the period of time covered in this report. All wells and borings were plugged and abandoned in accordance with the Monitoring Well Plugging and Abandonment Plan for the U.S. Department of Energy, Y-12 Plant, Oak Ridge, Tennessee.

  5. Fiscal year 1993 well plugging and abandonment program, Y-12 Plant, Oak Ridge, Tennessee

    Energy Technology Data Exchange (ETDEWEB)

    1993-09-01

    This report is a synopsis of the progress of the well plugging and abandonment program at the Y-12 Plant, Oak Ridge, Tennessee, from December 1992 through August 20, 1993. A total of 70 wells and borings were plugged and abandoned during the period of time covered in this report. All wells and borings were plugged and abandoned in accordance with the Monitoring Well Plugging and Abandonment Plan for the US Department of Energy, Y-12 Plant, Oak Ridge, Tennessee (HSW, Inc. 1991).

  6. Testing and Analysis of Sensor Ports

    Science.gov (United States)

    Zhang, M.; Frendi, A.; Thompson, W.; Casiano, M. J.

    2016-01-01

    This Technical Publication summarizes the work focused on the testing and analysis of sensor ports. The tasks under this contract were divided into three areas: (1) Development of an Analytical Model, (2) Conducting a Set of Experiments, and (3) Obtaining Computational Solutions. Results from the experiment using both short and long sensor ports were obtained using harmonic, random, and frequency sweep plane acoustic waves. An amplification factor of the pressure signal between the port inlet and the back of the port is obtained and compared to models. Comparisons of model and experimental results showed very good agreement.

  7. Polysaccharides and bacterial plugging. Final report, 1992--1993

    Energy Technology Data Exchange (ETDEWEB)

    Fogler, H.S.

    1995-02-01

    In situ core plugging experiments and transport experiments, using the model bacteria Leuconostoc m., have been conducted. Results demonstrated that cellular polysaccharide production increases cell distribution in porous media and caused an overall decrease in media permeability. Further, a parallel core plugging experiment was conducted and showed the feasibility of this system to divert injection fluid from high permeability zones into low permeability zones within porous media as is needed for profile modification. To implement this type of application, however, controlled placement of cells and rates of polymer production are needed. Therefore, kinetic studies were performed. A kinetic model was subsequently developed for Leuconostoc m. bacteria. This model is based on data generated from batch growth experiments and allows for the prediction of saccharide utilization, cell generation, and dextran production. These predictions can be used to develop injection strategies for field implementation. Transport and in situ growth micromodel experiments have shown how dextran allow cells to remain as clusters after cell division which enhanced cell capture and retention in porous media. Additional Damkohler experiments have been performed to determine the effects of the nutrient injection rate and nutrient concentration on the rate of porous media plugging. As shown experimentally and as predicted by a model for in situ growth, an increase in nutrient concentration and/or its injection rate will result in a faster rate of porous media plugging. Through continuum model simulations, it has been shown that the initial cell profiles play a key role on the core plugging rate. Controlling the location of the inoculating cells is thus another key factor in using bacteria for profile modification.

  8. Oscillation of an isolated liquid plug inside a dry capillary

    Science.gov (United States)

    Srinivasan, Vyas; Kumar, Siddhartha; Asfer, Mohammed; Khandekar, Sameer

    2017-11-01

    The present work reports an experimental study on the dynamics of partially wetting isolated liquid plug (DI water), which is made to oscillate inside a square, glass capillary tube (1 mm × 1 mm; 60 mm length). The liquid plug is made to oscillate pneumatically at two different frequencies (0.25 and 0.35 Hz), using a cam-follower mechanism. Bright field imaging is used to visualize the three-phase contact line behavior, while, micro-Particle Imaging Velocimetry (PIV) apparatus is used to discern the nature of flow inside the oscillating liquid plug. During a cycle, due to the partial wetting nature of DI water, the three-phase contact line at the menisci gets pinned at the extreme end of each stroke, where the dynamic apparent contact angle gets drastically altered before the initiation of the next stroke. The difference between the apparent contact angle of the front and rear meniscus are seen to be a function of the oscillating frequency; the difference increasing with increasing frequency. The flow inside the liquid plug reveals unique non-Poiseuille flow features near the meniscus, due to free-slip boundary condition, which leads to formation of distinct vortex pairs behind it. The vortices too change their direction during each stroke of the oscillation, eventually leading to an alternating recirculation pattern inside the plug. The results clearly indicate that improved mathematical models are required for predicting transport parameters in such flows, which are important in engineering systems such as pulsating heat pipes, lab-on-chip devices and PEM fuel cells.

  9. DEA Window Analysis for Measuring Port Efficiencies in Serbia

    Directory of Open Access Journals (Sweden)

    Danijela Pjevčević

    2012-01-01

    Full Text Available The aim of the paper is to apply Data Envelopment Analysis (DEA method in measuring and analyzing the efficiencies of ports on the river Danube. DEA window analysis is used to determine the efficiency of ports and to observe the possibility of changes in the port efficiency over time. A study is conducted to evaluate the efficiencies of ports on the territory of Serbia in order to identify the sources of inefficiencies and formulate proposals for improving the services of those ports and their operations through a four-year window analysis with port efficiency trends and average efficiencies. The progress is made in the measurement of port efficiency in relation to port productive activities - total area of warehouses, quay length, number of cranes and port throughput, for the Serbian river ports. Keywords: river ports, total area of warehouses, quay length, number of cranes, port throughput, port efficiency, DEA window analysis

  10. Perancangan Miniatur Traffic Light Dengan Mempergunakan Pengendali Port Paralel

    Directory of Open Access Journals (Sweden)

    Eka Wahyudi

    2012-05-01

    Full Text Available Port paralel tentunya sudah tidak asing lagi dalam dunia komputer. Hal tersebut disebabkan karena port paralel merupakan sarana komunikasi yang terdapat pada Personal Computer (PC. Dengan memanfaatkan port tersebut, saat ini komputer juga dapat dipergunakan untuk keperluan pengontrolan/pengendalian rangkaian listrik dengan memanfaatkan port paralel (port printer. Port paralel memiliki kecepatan transfer data yang lebih cepat apabila dibandingkan dengan port serial, maka dari itu port paralel lebih banyak dipergunakan untuk pengendalian nyala lampu (LED. Dengan memanfaatkan bantuan software Saraf Listrik versi 1.01, maka port paralel dapat menjadi alternatif baru untuk pengendalian traffic light.

  11. Non-Price Competition in the Port Sector: A Case Study of Ports in Turkey

    OpenAIRE

    Soner Esmer; Hong-Oanh Nguyen, Ph.D.; Yapa Mahinda Bandara, Ph.D.; Kazim Yeni, Ph.D.

    2016-01-01

    Although the port sector has been facing increasing competition, there is limited research on how ports compete using non-price competition strategies. There are a few studies on non-price competition in the port sector. However they mainly focus on the marketing aspect. This paper seeks to fill this gap in the literature, especially from a combined marketing-economic perspective. Especially the paper's main objective is to identify the determinants of non-price competition in the port sector...

  12. Alternative Fuels Data Center: Signage for Plug-In Electric Vehicle

    Science.gov (United States)

    Send a link to Alternative Fuels Data Center: Signage for Plug-In Electric Vehicle Charging Stations to someone by E-mail Share Alternative Fuels Data Center: Signage for Plug-In Electric Vehicle Charging Stations on Facebook Tweet about Alternative Fuels Data Center: Signage for Plug-In Electric Vehicle

  13. Alternative Fuels Data Center: Hybrid and Plug-In Electric Vehicle

    Science.gov (United States)

    Conversions Hybrid and Plug-In Electric Vehicle Conversions to someone by E-mail Share Alternative Fuels Data Center: Hybrid and Plug-In Electric Vehicle Conversions on Facebook Tweet about Alternative Fuels Data Center: Hybrid and Plug-In Electric Vehicle Conversions on Twitter Bookmark Alternative

  14. Test Confessions : A Study of Testing Practices for Plug-in Systems

    NARCIS (Netherlands)

    Greiler, M.; Van Deursen, A.; Storey, M.A.

    2011-01-01

    Testing plug-in-based systems is challenging due to complex interactions among many different plug-ins, and variations in version and configuration. The objective of this paper is to increase our understanding of what testers and developers think and do when it comes to testing plug-inbased systems.

  15. Rotating plug size study for liquid-metal fast breeder reactors

    International Nuclear Information System (INIS)

    Nemeth, L.J.

    1980-01-01

    A study was performed to evaluate possible rotating plug arrangements. The three-, two-, and one-rotating plug schemes were developed using a set of established restrictions and component sizes. The three-rotating plug configuration is the recommended reference design

  16. 30 CFR 250.1711 - When will MMS order me to permanently plug a well?

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 2 2010-07-01 2010-07-01 false When will MMS order me to permanently plug a well? 250.1711 Section 250.1711 Mineral Resources MINERALS MANAGEMENT SERVICE, DEPARTMENT OF THE... Activities Permanently Plugging Wells § 250.1711 When will MMS order me to permanently plug a well? MMS will...

  17. 19 CFR 101.3 - Customs service ports and ports of entry.

    Science.gov (United States)

    2010-04-01

    ... and Service Ports. Many of the ports listed were created by the President's message of March 3, 1913....S.C. 1). Subsequent orders of the President or of the Secretary of the Treasury which affected these... Port of the Delaware River and Bay described in T.D. 96-4. Perth Amboy New Mexico Albuquerque Including...

  18. Porting Biomedical Applications to Grids

    NARCIS (Netherlands)

    T.A. Knoch (Tobias)

    2008-01-01

    textabstractToday advances in scientific research as well as clinical diagnostics and treatment are inevitably connected with information solutions concerning computation power and information storage. The needs for information technology are enormous and are in many cases the limiting

  19. Port-Orford-Cedar Root Disease

    Science.gov (United States)

    Lewis F. Roth; Robert D. Jr. Harvey; John T. Kliejunas

    1987-01-01

    The most serious disease of Port-Orford-cedar (Chamaecyparis lawsoniana (A. Murr.) Parl.) is a root disease caused by the fungus Phytophthora lateralis. Nursery stock, ornamentals, and timber trees are subject to attack. Other species of Chamaecyparis are less susceptible than Port-Orford-cedar, and trees of other genera are not affected.

  20. Are we connected? : Ports in Global Networks

    NARCIS (Netherlands)

    R.A. Zuidwijk (Rob)

    2015-01-01

    markdownabstractAbstract Global supply chains are built on organizational, information, and logistics networks. Ports are connected via these networks and also need to connect these networks. Synchromodality is an innovative concept for container transportation, and the port plays an important

  1. Lessons from Hurricane Sandy for port resilience.

    Science.gov (United States)

    2013-12-01

    New York Harbor was directly in the path of the most damaging part of Hurricane Sandy causing significant impact on many of the : facilities of the Port of New York and New Jersey. The U.S. Coast Guard closed the entire Port to all traffic before the...

  2. Visual Support for Porting Large Code Bases

    NARCIS (Netherlands)

    Broeksema, Bertjan; Telea, Alexandru

    2011-01-01

    We present a tool that helps C/C++ developers to estimate the effort and automate software porting. Our tool supports project leaders in planning a porting project by showing where a project must be changed, how many changes are needed, what kinds of changes are needed, and how these interact with

  3. Single port VATS: recent developments in Asia.

    Science.gov (United States)

    Yu, Peter S Y; Capili, Freddie; Ng, Calvin S H

    2016-03-01

    Single port video-assisted thoracic surgery (VATS) is the most recent evolution in minimally invasive thoracic surgery. With increasing global popularity, the single port VATS approach has been adopted by experienced thoracic surgeons in many Asian countries. From initial experience of single port VATS lobectomy to the more complex sleeve resection procedures now forming part of daily practice in some Asia institutes, the region has been the proving ground for single port VATS approaches' feasibility and safety. In addition, certain technical refinements in single port VATS lung resection and lymph node dissection have also sprung from Asia. Novel equipment designed to facilitate single port VATS allowing further reduce access trauma are being realized by the partnership between surgeons and the industries. Advanced thoracoscopes and staplers that are narrower and more maneuverable are particularly important in the smaller habitus of patients from Asia. These and similar new generation equipment are being applied to single port VATS in novel ways. As dedicated thoracic surgeons in the region continue to striving for excellence, innovative ideas in single incision access including subxiphoid and embryonic natural-orifice transluminal endoscopic surgery (e-NOTES) have been explored. Adjunct techniques and technology used in association with single port VATS such as non-intubated surgery, hybrid operating room image guidance and electromagnetic navigational bronchoscopy are all in rapid development in Asia.

  4. Cyber security in ports : Business as usual

    NARCIS (Netherlands)

    Moerel, Lokke; Dezeure, Freddy

    2017-01-01

    Our paper summarizes the risks and provides concrete and pragmatic proposals to increase substantially the cyber maturity and resilience in the ports by organizing training and awareness raising, fostering cooperation and information exchange both between the stakeholders in the ports and across the

  5. On Distributed Port-Hamiltonian Process Systems

    NARCIS (Netherlands)

    Lopezlena, Ricardo; Scherpen, Jacquelien M.A.

    2004-01-01

    In this paper we use the term distributed port-Hamiltonian Process Systems (DPHPS) to refer to the result of merging the theory of distributed Port-Hamiltonian systems (DPHS) with the theory of process systems (PS). Such concept is useful for combining the systematic interconnection of PHS with the

  6. Rotterdam as a World Port City

    NARCIS (Netherlands)

    Wouter Jacobs; Menno Huijs; Isabelle Vries

    2015-01-01

    Most studies and models on the port-city interface focus on the inevitable process in which ports and cities grow apart, both spatially and economically. What is often overlooked is the relationships that remain in the form of maritime business services (finance, insurance, legal). These maritime

  7. Working with Nature in Wadden Sea Ports

    NARCIS (Netherlands)

    Baptist, M.J.; Eekelen, van E.; Dankers, P.J.T.; Grasmeijer, B.; Kessel, van T.; Maren, van D.S.

    2017-01-01

    Wadden Sea ports are situated at the border of the UNESCO World Heritage site Wadden Sea. Because of the protected status of this area, developing new economic activities is not straightforward. However, maintaining and developing port activities is needed to safeguard the economic viability of the

  8. Dry Port Development: A Systematic Review

    Directory of Open Access Journals (Sweden)

    Fatimazahra BENTALEB

    2015-12-01

    Full Text Available Studies on dry ports as nodes in multimodal transport have been expanded to decrease the mounting congestion on seaports. The principal objective of this study is to inspect how dry port researches have been conducted from different perspective. This paper tries to recap the existing researches that aimed to study dry port concept via a systematic review, to present a general overview of the researches on our relevant region and propose a classification for these researches. This paper present a systematic review of dry port that looks to illustrate the progress of researches on this area between 1986 and 2015, collecting researches on dry port concept and analyzing the main characteristics of the dry port development and their contribution to the multimodal transport. The results indicated that most dry port studies considerate the strategic level and concentrate in the Asian continent. Studies regarding other decision levels and continents have to be developed in further researches. Although the existing studies make a contribution in dry port concept, they allow gaps in terms of operational and tactical decision levels considering their limited geographical region.

  9. Laser treatment of Port-wine stains

    OpenAIRE

    Boffa, Michael J.

    2001-01-01

    A state-of-the-art pulsed dye laser machine to treat port-wine stains and other vascular lesions has been available in the Malta Health Service since 1999. This article reviews the pathophysiology and clinical features of port- wine stains and describes the principles of laser treatment for this condition.

  10. Field-test programs of borehole plugs in southeastern New Mexico

    International Nuclear Information System (INIS)

    Christensen, C.L.; Peterson, E.W.

    1981-01-01

    This paper gives a general overview of the repository-sealing field test effort being conducted by Sandia National Laboratories in support of the Waste Isolation Pilot Plant in southeast New Mexico. Summary descriptions of supporting activities, such as performance assessment and plugging materials development, are included to create the connection between modeling and laboratory activities as they relate to field results. Results of tests on a portion of a 17-year-old plug (Plug 217) recovered from a mine horizon and the Bell Canyon Test, in which a cement plug was emplaced to isolate a naturally pressurized aquifer, are given. Conclusions from these field plugging tests are included

  11. Ports Primer: 3.3 Federal and International Governance

    Science.gov (United States)

    State and local governments are important players in port governance and in oversight of transportation projects that may affect ports. Private corporations may also play a role if they lease or own a terminal at a port.

  12. Two-port access versus four-port access laparoscopic ovarian cystectomy.

    Science.gov (United States)

    Choi, Won-Kyu; Kim, Jang-Kew; Yang, Jung-Bo; Ko, Young-Bok; Nam, Sang-Lyun; Lee, Ki-Hwan

    2014-09-01

    This study was conducted to compare the surgical outcomes between two-port access and four-port access laparoscopic ovarian cystectomy. Four hundred and eighty nine patients who had received two-port access laparoscopic ovarian cystectomy (n=175) and four-port access laparoscopic ovarian cystectomy (n=314) in Chungnam National University Hospital from January 2009 to August 2012 were analyzed retrospectively. The data were compared between the bilaterality of the cysts and cyst diameter of less than 6 cm and 6 cm or more. There were no significant differences in patient's age, parity, body weight, body mass index and history of previous surgery between the two-port and four-port access laparoscopy group. Bilaterality of ovarian cysts was more in fourport access laparoscopy group (13.7% vs. 32.5%, P=0.000). There were no significant differences in operation time, hemoglobin change, hospital stay, adhesiolysis, transfusion, and insertion of hemo-vac between the two-port and four-port access laparoscopy group for size matched compare. However additional analgesics were more in four-port access laparoscopy group for unilateral ovarian cystectomy. Two-port access laparoscopic surgery was feasible and safe for unilateral and bilateral ovarian cystectomy compare with four-port access laparoscopic surgery.

  13. Influence of Port Policy on the Development of Croatian Container Ports

    Directory of Open Access Journals (Sweden)

    Čedomir Dundović

    2002-03-01

    Full Text Available It is important to consider the port development throughoutthe world from the aspect of economical, transport and portpolicy and their mutual impact on commerce and efficiency ofports. By examining such relations in the context of developmentof the Croatian container ports, it is possible to define reasonsfor lagging behind of Croatian ports compared to theworld movements.The main reason for the negative trend of development ofCroatian container ports lies in the non-existence of adequatemeasures of transport, maritime and port policy. Analysis ofstatistics over the past decade and comparison of structure andvolume of the general cargo traffic in the Rijeka port and theneighbouring ports in the area of North Adriatic are both showingsignificant size discrepancy and uncompetitiveness of theCroatian port. Disturbances that have brought to such a situationresult from inadequate port policy and non-harmonisedactivities between various modes of transport.In order to overcome such situation, the authors suggest determiningof clear tasks, goals and measures of the port policythat have to be undertaken so that the Croatian policy could becompatible with the main aspects, development tendencies andmeasures of theE U port policy.

  14. Colonial Origins of the Port of Buenaventura

    Directory of Open Access Journals (Sweden)

    Alonso Valencia Llano

    2014-07-01

    Full Text Available This article studies the origins of the Port of Buenaventura in the New Kingdom of Granada. It begins with the process of exploration of the coastal territory in order to highlight the different sites in which it was situated, demonstrating that it began as a river port and was later resituated and gradually converted into a maritime port. In addition, this article analyzes the problems it faced, such as the dificulty of communication with the interior of the country, the indigenous resistance that caused the destruction of the town, and inally the necessity of populating the zone with black slaves in order to exploit the mining border. This study also discusses how this port was controlled by the elite of the city of Cali, until the Republican period when it became the sole Colombian port on the Paciic Ocean.

  15. Integrated circuit test-port architecture and method and apparatus of test-port generation

    Science.gov (United States)

    Teifel, John

    2016-04-12

    A method and apparatus are provided for generating RTL code for a test-port interface of an integrated circuit. In an embodiment, a test-port table is provided as input data. A computer automatically parses the test-port table into data structures and analyzes it to determine input, output, local, and output-enable port names. The computer generates address-detect and test-enable logic constructed from combinational functions. The computer generates one-hot multiplexer logic for at least some of the output ports. The one-hot multiplexer logic for each port is generated so as to enable the port to toggle between data signals and test signals. The computer then completes the generation of the RTL code.

  16. Dual-port distal gastrectomy for the early gastric cancer

    OpenAIRE

    Kashiwagi, Hiroyuki; Kumagai, Kenta; Monma, Eiji; Nozue, Mutsumi

    2014-01-01

    Background Although recent trends in laparoscopic procedures have been toward minimizing the number of incisions, four or five ports are normally required to complete laparoscopic gastrectomy because of the complexity of this procedure. Multi-channel ports, such as the SILS port (Covidien, JAPAN), are now available and are crucial for performing single-incision laparoscopic surgery (SILS) or reduced port surgery (RPS). We carried out reduced port distal gastrectomy (RPDG) using a dual-port me...

  17. E-Commerce in Ports

    Directory of Open Access Journals (Sweden)

    Elen Twrdy

    2002-01-01

    Full Text Available EDI (Electronic Data Interchange and electronic businessshould be looked upon as a natural evolution in the internationaltrade and transport cycle. One of the principal reasonsfor starting to use EDI are the heaps of documents written,shifted, handled, conected, transcribed and copied for normalbusiness and administrative transactions. EDJ and in generalelectronic business would have none of the disadvantages ofpaper documents and have already brought substantial benefitsand savings to companies that implement it.Most port community systems today still do not provide forelectronic transfer of funds or for electronic interchange of invoicesand other trade documents, for instance bills of lading.Such services are specific toe-business and they are the necessarytransport-related documents.

  18. Flow induced vibration studies on PFBR control plug components

    Energy Technology Data Exchange (ETDEWEB)

    Prakash, V., E-mail: prakash@igcar.gov.in [Fast Reactor Technology Group, Indira Gandhi Centre for Atomic Research, Kalpakkam, Tamilnadu (India); Kumar, P. Anup; Anandaraj, M.; Thirumalai, M.; Anandbabu, C.; Rajan, K.K. [Fast Reactor Technology Group, Indira Gandhi Centre for Atomic Research, Kalpakkam, Tamilnadu (India)

    2012-09-15

    Highlights: Black-Right-Pointing-Pointer Flow induced vibration studies on Prototype Fast Breeder Reactor control plug model carried out. Black-Right-Pointing-Pointer Velocity similitude was followed for the study. Black-Right-Pointing-Pointer Frequencies and amplitude of vibrations of various control plug components measured. Black-Right-Pointing-Pointer Overall values of vibration are well within permissible limits. - Abstract: The construction of Prototype Fast Breeder Reactor (PFBR), a 500 MWe liquid sodium cooled reactor, is in progress at Kalpakkam in India. Control plug (CP) is located right above the core subassemblies in the hot pool. Control plug is an important component as many of the critical reactor parameters are sensed and controlled by the components housed in the control plug assembly. In PFBR primary circuit, components are basically thin walled, slender shells with diameter to thickness ratio ranging from 100 to 650. These components are prone to flow induced vibrations. The existence of free liquid (sodium) surfaces, which is the source of sloshing phenomenon and the operation of primary sodium pump in the primary pool are other potential sources of vibration of reactor components. Control plug is a hollow cylindrical shell structure and provides passages and support for 12 absorber rod drive mechanisms (ARDM) which consists of 9 control and safety rods and 3 diverse safety rods, 210 thermo wells to measure the sodium temperature at the exit of various fuel subassemblies, three failed fuel localization modules (FFLM) and acoustic detectors. It consists of a core cover plate (CCP), which forms the bottom end, two intermediate supports plate, i.e. lower stay plate (LSP) and upper stay plate (USP) and an outer shell. The CCP is located at a distance of 1.3 m from the core top. With such a gap, there will be long free hanging length of the thermocouple sleeves, Delayed neutron detector (DND) sampling tubes and ARDM shroud tubes and hence they are

  19. Wireless Plug and Play Control Systems: Hardware, Networks, and Protocols

    DEFF Research Database (Denmark)

    Meybodi, Soroush Afkhami

    2012-01-01

    This dissertation reports the result of efforts to identify and solve the problems that arise when a control system is to be designed for various industrial case studies of the Plug and Play Process Control (P3C) project that require autonomous addition/removal of sensors, actuators and subsystems...... in only one of the P3C case studies where all of the nodes of the wireless networked control system are placed underground and should be able to transmit data among themselves. It is not a trivial problem because the well known radio frequency electromagnetic waves face serious difficulties penetrating...... is recommended for wireless plug and play control systems. Formation and maintenance of clusters of nodes are directly linked to the top level application layer via a novel application-based routing metric. The proposed routing metric facilitates implementation of the networking topology in accordance...

  20. [Plug-technique for umbilical hernia repair in the adult].

    Science.gov (United States)

    Brancato, G; Privitera, A; Gandolfo, L; Donati, M; Caglià, P

    2002-02-01

    Umbilical hernia represents 6% of all abdominal wall hernias in the adult. Surgical repair should always be carried out due to possible occurrence of complications. Aim of this paper is to evaluate the efficacy of the plug-technique. From October 1995 to April 2000, the authors performed 21 operations for acquired umbilical hernia with a defect smaller than 4 cm. Local anesthesia was used and a light intravenous sedation added in particularly anxious patients. The repair was achieved by insertion of a polypropylene dart plug sutured to the margins of the hernial defect. All patients were up and about straightaway and were discharged within 24 hours of surgery. Postoperative pain was mild and required hospital analgesia in only 19% of cases and domiciliary analgesia in 24%. During a follow-up ranging from 6 to 60 months (mean 30), only one recurrence has been recorded. This tension-free technique allows immediate rehabilitation, with few complications and a low recurrence rate.

  1. A Plug and Produce Framework for Industrial Collaborative Robots

    DEFF Research Database (Denmark)

    Schou, Casper; Madsen, Ole

    2017-01-01

    Collaborative robots are today ever more interesting in response to the increasing need for agile manufacturing equipment. Contrary to traditional industrial robots, collaborative robots are intended for working in dynamic environments alongside the production staff. To cope with the dynamic...... environment and workflow, new configuration and control methods are needed compared to those of traditional industrial robots. The new methods should enable shop floor operators to reconfigure the robot. This article presents a plug and produce framework for industrial collaborative robots. The article...... focuses on the control framework enabling quick and easy exchange of hardware modules as an approach to achieving plug and produce. To solve this, an agent-based system is proposed building on top of the robot operating system. The framework enables robot operating system packages to be adapted...

  2. Plug and Process Loads Capacity and Power Requirements Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Sheppy, M.; Gentile-Polese, L.

    2014-09-01

    This report addresses gaps in actionable knowledge that would help reduce the plug load capacities designed into buildings. Prospective building occupants and real estate brokers lack accurate references for plug and process load (PPL) capacity requirements, so they often request 5-10 W/ft2 in their lease agreements. Limited initial data, however, suggest that actual PPL densities in leased buildings are substantially lower. Overestimating PPL capacity leads designers to oversize electrical infrastructure and cooling systems. Better guidance will enable improved sizing and design of these systems, decrease upfront capital costs, and allow systems to operate more energy efficiently. The main focus of this report is to provide industry with reliable, objective third-party guidance to address the information gap in typical PPL densities for commercial building tenants. This could drive changes in negotiations about PPL energy demands.

  3. Strength and stability of microbial plugs in porous media

    Energy Technology Data Exchange (ETDEWEB)

    Sarkar, A.K. [NIPER/BDM-Oklahoma, Inc., Bartlesville, OK (United States); Sharma, M.M.; Georgiou, G. [Univ. of Texas, Austin, TX (United States)

    1995-12-31

    Mobility reduction induced by the growth and metabolism of bacteria in high-permeability layers of heterogeneous reservoirs is an economically attractive technique to improve sweep efficiency. This paper describes an experimental study conducted in sandpacks using an injected bacterium to investigate the strength and stability of microbial plugs in porous media. Successful convective transport of bacteria is important for achieving sufficient initial bacteria distribution. The chemotactic and diffusive fluxes are probably not significant even under static conditions. Mobility reduction depends upon the initial cell concentrations and increase in cell mass. For single or multiple static or dynamic growth techniques, permeability reduction was approximately 70% of the original permeability. The stability of these microbial plugs to increases in pressure gradient and changes in cell physiology in a nutrient-depleted environment needs to be improved.

  4. Plug and Play Framework for Theories of Social Group Dynamics

    DEFF Research Database (Denmark)

    Rehm, Matthias; Endrass, Birgit; André, Elisabeth

    2006-01-01

    We present an extensible framework for behavior control of social agents in a multi-agent system that has the following features. It implements a basic repertoire of socio-psychological models of behavior and interpersonal interactions that can be plugged and unplugged at will depending on the sp......We present an extensible framework for behavior control of social agents in a multi-agent system that has the following features. It implements a basic repertoire of socio-psychological models of behavior and interpersonal interactions that can be plugged and unplugged at will depending...... on the specific context of the application. This enables us to test several theories in isolation or combination to increase the transparency of the system and to investigate how the inclusion of a certain theory influences the behavior of the agents. Unlike earlier approaches, our approach is not bound...

  5. Enhancements to the Redmine Database Metrics Plug in

    Science.gov (United States)

    2017-08-01

    management web application has been adopted within the US Army Research Laboratory’s Computational and Information Sciences Directorate as a database...project management web application.∗ The Redmine plug-in† enabled the use of the numerous, powerful features of the web application. The many...distribution is unlimited. 2 • Selectable export of citations/references by type, writing style , and FY • Enhanced naming convention options for

  6. "Plug-and-play" edge-preserving regularization

    DEFF Research Database (Denmark)

    Chen, Donghui; Kilmer, Misha E.; Hansen, Per Christian

    2014-01-01

    In many inverse problems it is essential to use regularization methods that preserve edges in the reconstructions, and many reconstruction models have been developed for this task, such as the Total Variation (TV) approach. The associated algorithms are complex and require a good knowledge of large...... cosine transform.hence the term "plug-and-play" . We do not attempt to improve on TV reconstructions, but rather provide an easy-to-use approach to computing reconstructions with similar properties....

  7. Plug-In Electric Vehicle Handbook for Workplace Charging Hosts

    Energy Technology Data Exchange (ETDEWEB)

    None

    2013-08-01

    Plug-in electric vehicles (PEVs) have immense potential for increasing the country's energy, economic, and environmental security, and they will play a key role in the future of U.S. transportation. By providing PEV charging at the workplace, employers are perfectly positioned to contribute to and benefit from the electrification of transportation. This handbook answers basic questions about PEVs and charging equipment, helps employers assess whether to offer workplace charging for employees, and outlines important steps for implementation.

  8. A Rigorous Methodology for Analyzing and Designing Plug-Ins

    DEFF Research Database (Denmark)

    Fasie, Marieta V.; Haxthausen, Anne Elisabeth; Kiniry, Joseph

    2013-01-01

    . This paper addresses these problems by describing a rigorous methodology for analyzing and designing plug-ins. The methodology is grounded in the Extended Business Object Notation (EBON) and covers informal analysis and design of features, GUI, actions, and scenarios, formal architecture design, including...... behavioral semantics, and validation. The methodology is illustrated via a case study whose focus is an Eclipse environment for the RAISE formal method's tool suite....

  9. Mesh Plug Repair of Inguinal Hernia; Single Surgeon Experience

    Directory of Open Access Journals (Sweden)

    Ahmet Serdar Karaca

    2013-10-01

    Full Text Available Aim: Mesh repair of inguinal hernia repairs are shown to be an effective and reliable method. In this study, a single surgeon%u2019s experience with plug-mesh method performs inguinal hernia repair have been reported. Material and Method: 587 patients with plug-mesh repair of inguinal hernia, preoperative age, body / mass index, comorbid disease were recorded in terms of form. All of the patients during the preoperative and postoperative hernia classification of information, duration of operation, antibiotics, perioperative complications, and later, the early and late postoperative complications, infection, recurrence rates and return to normal daily activity, verbal pain scales in terms of time and postoperative pain were evaluated. Added to this form of long-term pain ones. The presence of wound infection was assessed by the presence of purulent discharge from the incision. Visual analog scale pain status of the patients was measured. Results: 587 patients underwent repair of primary inguinal hernia mesh plug. One of the patients, 439 (74% of them have adapted follow-ups. Patients%u2019 ages ranged from 18-86. Was calculated as the mean of 47±18:07. Follow-up period of the patients was found to be a minimum of 3 months, maximum 55 months. Found an average of 28.2±13.4 months. Mean duration of surgery was 35.07±4.00 min (min:22mn-max:52mn, respectively. When complication rates of patients with recurrence in 2 patients (0.5%, hematoma development (1.4% in 6 patients, the development of infection in 11 patients (2.5% and long-term groin pain in 4 patients (0.9% appeared. Discussion: In our experience, the plug-mesh repair of primary inguinal hernia repair safe, effective low recurrence and complication rates can be used.

  10. Glow plug ignitor tests in H2 mixtures

    International Nuclear Information System (INIS)

    Liparulo, N.J.; Olhoeft, J.E.; Paddleford, D.F.

    1981-01-01

    The AEP, TVA and DUKE Electric Power companies, in cooperation with Westinghouse Electric Corporation have defined a testing program to determine the effectiveness of a glow plug hydrogen ignition system. The ignitor's capability was demonstrated for both static and dynamic conditions. Tests were performed with both spray addition and fan induced turbulence. It ignited hydrogen for all tests performed. The results of tests did not differ significantly from similar tests data previously reported. This report presents a discussion of the test results

  11. National Plug-In Electric Vehicle Infrastructure Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Wood, Eric W. [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Rames, Clement L. [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Muratori, Matteo [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Srinivasa Raghavan, Seshadri [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Melaina, Marc W. [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2017-09-15

    This document describes a study conducted by the National Renewable Energy Laboratory quantifying the charging station infrastructure required to serve the growing U.S. fleet of plug-in electric vehicles (PEVs). PEV sales, which include plug-in hybrid electric vehicles (PHEVs) and battery electric vehicles (BEVs), have surged recently. Most PEV charging occurs at home, but widespread PEV adoption will require the development of a national network of non-residential charging stations. Installation of these stations strategically would maximize the economic viability of early stations while enabling efficient network growth as the PEV market matures. This document describes what effective co-evolution of the PEV fleet and charging infrastructure might look like under a range of scenarios. To develop the roadmap, NREL analyzed PEV charging requirements along interstate corridors and within urban and rural communities. The results suggest that a few hundred corridor fast-charging stations could enable long-distance BEV travel between U.S. cities. Compared to interstate corridors, urban and rural communities are expected to have significantly larger charging infrastructure requirements. About 8,000 fast-charging stations would be required to provide a minimum level of coverage nationwide. In an expanding PEV market, the total number of non-residential charging outlets or 'plugs' required to meet demand ranges from around 100,000 to more than 1.2 million. Understanding what drives this large range in capacity requirements is critical. For example, whether consumers prefer long-range or short-range PEVs has a larger effect on plug requirements than does the total number of PEVs on the road. The relative success of PHEVs versus BEVs also has a major impact, as does the number of PHEVs that charge away from home. This study shows how important it is to understand consumer preferences and driving behaviors when planning charging networks.

  12. National Plug-In Electric Vehicle Infrastructure Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Muratori, Matteo [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Rames, Clement L [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Srinivasa Raghavan, Sesha [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Melaina, Marc W [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Wood, Eric W [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2018-02-07

    This presentation describes a study conducted by the National Renewable Energy Laboratory quantifying the charging station infrastructure required to serve the growing U.S. fleet of plug-in electric vehicles (PEVs). PEV sales, which include plug-in hybrid electric vehicles (PHEVs) and battery electric vehicles (BEVs), have surged recently. Most PEV charging occurs at home, but widespread PEV adoption will require the development of a national network of non-residential charging stations. Installation of these stations strategically would maximize the economic viability of early stations while enabling efficient network growth as the PEV market matures. This document describes what effective co-evolution of the PEV fleet and charging infrastructure might look like under a range of scenarios. To develop the roadmap, NREL analyzed PEV charging requirements along interstate corridors and within urban and rural communities. The results suggest that a few hundred corridor fast-charging stations could enable long-distance BEV travel between U.S. cities. Compared to interstate corridors, urban and rural communities are expected to have significantly larger charging infrastructure requirements. About 8,000 fast-charging stations would be required to provide a minimum level of coverage nationwide. In an expanding PEV market, the total number of non-residential charging outlets or 'plugs' required to meet demand ranges from around 100,000 to more than 1.2 million. Understanding what drives this large range in capacity requirements is critical. For example, whether consumers prefer long-range or short-range PEVs has a larger effect on plug requirements than does the total number of PEVs on the road. The relative success of PHEVs versus BEVs also has a major impact, as does the number of PHEVs that charge away from home. This study shows how important it is to understand consumer preferences and driving behaviors when planning charging networks.

  13. The Practice of Guangzhou Port Planning Environmental Impact Assessment

    Science.gov (United States)

    Wang, Ning; Zhao, Junjie; Shou, Youping; Qiao, Jianzhe; Dong, Shipei; Zhang, Lu

    2018-01-01

    In this paper, the effects of the implementation of Guangzhou port plan were analyzed from hydrological condition, water environment and ecological environment. Regional water environmental carrying capacity was analyzed. Guangzhou port is a main port in the coast of China, it is an important port of foreign trade in south China, it is an important port for energy supplies and raw materials in Guangdong province [1]. With the shipping channel condition improvement and the construction of large specialized container port area, Guangzhou port will gradually become trunk line port of container transport in south China.

  14. Burst Test Qualification Analysis of DWPF Canister-Plug Weld

    International Nuclear Information System (INIS)

    Gupta, N.K.; Gong, Chung.

    1995-02-01

    The DWPF canister closure system uses resistance welding for sealing the canister nozzle and plug to ensure leak tightness. The welding group at SRTC is using the burst test to qualify this seal weld in lieu of the shear test in ASME B ampersand PV Code, Section IX, paragraph QW-196. The burst test is considered simpler and more appropriate than the shear test for this application. Although the geometry, loading and boundary conditions are quite different in the two tests, structural analyses show similarity in the failure mode of the shear test in paragraph QW-196 and the burst test on the DWPF canister nozzle Non-linear structural analyses are performed using finite element techniques to study the failure mode of the two tests. Actual test geometry and realistic stress strain data for the 304L stainless steel and the weld material are used in the analyses. The finite element models are loaded until failure strains are reached. The failure modes in both tests are shear at the failure points. Based on these observations, it is concluded that the use of a burst test in lieu of the shear test for qualifying the canister-plug weld is acceptable. The burst test analysis for the canister-plug also yields the burst pressures which compare favorably with the actual pressure found during burst tests. Thus, the analysis also provides an estimate of the safety margins in the design of these vessels

  15. End plug for fuel rod and welding method therefor

    International Nuclear Information System (INIS)

    Yoneda, Hiroshi; Murakami, Kazuo; Oyama, Jun-ichi.

    1996-01-01

    An end plug of a fuel rod comprises a pressure-insertion portion having a diameter somewhat greater than the inner diameter of a fuel cladding tube and a welding portion having a diameter substantially the same as the outer diameter of the cladding tube. A V-shaped recess having an outer diameter smaller than the greatest outer diameter of the pressure-insertion portion is formed over the entire circumferential surface of the outer circumference of the connection portion of the pressure-insertion portion and the welding portion. The pressure-insertion portion of the end plug is inserted to the end of the cladding tube till the end of the cladding tube abuts against the inclined surface of the V-shaped recess. The abutting surfaces of the end plug and the cladding tube are subjected to resistance welding in this state. The inner portion bulged from the inclined surface of the V-shaped recess is filled in the recess in a molten state. Lowering of temperature of the cladding tube in the vicinity of the welded portion is decreased by γ heat during reactor operation. Accordingly, lowering of ductility of the cladding tube and degradation of material of the welded region due to segregation of hydrogen in the cladding tube can be suppressed. (I.N.)

  16. A direct digital controller for an automatic sodium plugging meter

    International Nuclear Information System (INIS)

    Tobias, A.

    1977-07-01

    A plugging meter is a device for monitoring the impurity level of liquid sodium. It is used to measure the temperature at which an impurity precipitates or re-dissolves at a restricting orifice. The concentration of the impurity may be then deduced from known solubility/temperature relationships. A software controller for a sodium plugging meter has been implemented on a PDP-11 using SWEPSPEED. The algorithm used to perform both flow and temperature control functions is based on a modified standard three-term controller. Both design and operation of the controller are described. The functions which may be performed by the controller are: (i) maintain a steady temperature at the restricting orifice, (ii) perform a temperature ramp at a rate defined by the operator, and (iii) maintain a partial plug of impurities at the orifice by appropriate manipulation of the temperature. Accuracies so far achieved are approximately +- 5% for flow control and better that +- 1 0 C for temperature control. (author)

  17. Geochemical factors in borehole-shaft plug longevity

    International Nuclear Information System (INIS)

    Roy, D.M.

    1981-01-01

    Geochemical investigations that address factors controlling the longevity of repository sealing materials in a geochemical environment are discussed. Studies are being made of cement-based materials as major candidates for seals for borehole plugging, and shaft and tunnel sealing in certain potential repository environments. Factors controlling the extent of attainment of equilibrium of the plug components with time and the rate of approach to a state of stable equilibrium of the plug component chemical subsystem within the total system are discussed. The effect of these factors on changes in physical, mechanical and thermal properties of a seal system, and the consequent effectiveness of the seal in preventing transport of radioactive waste species are the dominant features to be determined. Laboratory experiments on the effects of anticipated temperature, pressure, and environmental factors (including chemical composition and specific rock type) are described. Thermodynamic studies are used to determine the potentially stable reaction products under conditions similar to those anticipated for the repository boreholes, shafts, and tunnels during and after the operating stage. Multitemperature reaction series are studied, and reaction kinetics are investigated for the purpose of predicting the course of likely reactions. Detailed studies of permeability, diffusion, and interfacial properties and chemical and microphase characterization of the products of experiments are carried out. Characterization studies of old and ancient cements, mortars, and concretes and prototype man-made seal materials are performed to further assess the factors associated with longevity

  18. Selecting a Control Strategy for Plug and Process Loads

    Energy Technology Data Exchange (ETDEWEB)

    Lobato, C.; Sheppy, M.; Brackney, L.; Pless, S.; Torcellini, P.

    2012-09-01

    Plug and Process Loads (PPLs) are building loads that are not related to general lighting, heating, ventilation, cooling, and water heating, and typically do not provide comfort to the building occupants. PPLs in commercial buildings account for almost 5% of U.S. primary energy consumption. On an individual building level, they account for approximately 25% of the total electrical load in a minimally code-compliant commercial building, and can exceed 50% in an ultra-high efficiency building such as the National Renewable Energy Laboratory's (NREL) Research Support Facility (RSF) (Lobato et al. 2010). Minimizing these loads is a primary challenge in the design and operation of an energy-efficient building. A complex array of technologies that measure and manage PPLs has emerged in the marketplace. Some fall short of manufacturer performance claims, however. NREL has been actively engaged in developing an evaluation and selection process for PPLs control, and is using this process to evaluate a range of technologies for active PPLs management that will cap RSF plug loads. Using a control strategy to match plug load use to users' required job functions is a huge untapped potential for energy savings.

  19. Predictions of hydrate plug dissociation with electrical heating

    Energy Technology Data Exchange (ETDEWEB)

    Davies, S.R.; Ivanic, J.; Sloan, E.D.

    2005-07-01

    The rate of dissociation for cylindrical hydrate plugs by the application of radial electrical heating was investigated for structure I and structure II hydrates for pressures of 7 MPa (1000 psia) and 14 MPa (2000 psia). Heating rates of 2.3 kWm{sup -3}, 4.5 kWm-3 and 6.8 kWm{sup -3} were investigated for a plug 91.4 cm (36 inches) in length and 2.54 cm (1 inch) in diameter. A heat transfer model was developed in cylindrical coordinates based on Fourier's Law with a boundary condition of constant heat flux at the pipe wall. The equation set was solved numerically using a finite difference grid and the standard explicit scheme. The model was found to replicate well the experimental observations with no fitted parameters. A computer program was formulated to allow the practicing engineer to simulate the dissociation of industrial hydrates with minimal complexity. This program was incorporated into the latest version of our CSMPlug program which has been used by a number of energy companies to predict hydrate plug dissociation rates in the field. (Author)

  20. An Energy Saving Green Plug Device for Nonlinear Loads

    Science.gov (United States)

    Bloul, Albe; Sharaf, Adel; El-Hawary, Mohamed

    2018-03-01

    The paper presents a low cost a FACTS Based flexible fuzzy logic based modulated/switched tuned arm filter and Green Plug compensation (SFC-GP) scheme for single-phase nonlinear loads ensuring both voltage stabilization and efficient energy utilization. The new Green Plug-Switched filter compensator SFC modulated LC-Filter PWM Switched Capacitive Compensation Devices is controlled using a fuzzy logic regulator to enhance power quality, improve power factor at the source and reduce switching transients and inrush current conditions as well harmonic contents in source current. The FACTS based SFC-GP Device is a member of family of Green Plug/Filters/Compensation Schemes used for efficient energy utilization, power quality enhancement and voltage/inrush current/soft starting control using a dynamic error driven fuzzy logic controller (FLC). The device with fuzzy logic controller is validated using the Matlab / Simulink Software Environment for enhanced power quality (PQ), improved power factor and reduced inrush currents. This is achieved using modulated PWM Switching of the Filter-Capacitive compensation scheme to cope with dynamic type nonlinear and inrush cyclical loads..

  1. Šport in humanistika

    Directory of Open Access Journals (Sweden)

    Jože Vogrinc

    2012-07-01

    Full Text Available O tem, ali je šport »neresen« pojav ali pojav, ki razkriva bistvene razsežnosti tistega, za kar človeku gre, se pogledi razhajajo. Glede na to, da so humanistične študije športa vsaj na prvi pogled nekje na obrobju ved, ki jih združuje Filozofska fakulteta, bi morda veljalo, da ga ne moremo primerjati z globoko resnimi temami, zlasti pa ne z najnovejšimi resnimi zahtevami, ki jih družba postavlja univerzi in znanostim: pripomoči k višji donosnosti in poslovnosti podjetništva ter ohranjati tradicijo in krepiti življenjsko moč naroda. Pa se že pri tem izkaže, da športa ne gre preveč zapostavljati; po eni strani je že nekaj desetletij, kar je postal izjemno kapitalsko zanimivo in donosno področje, v katero podjetniki bodisi vlagajo, da bi dosegali dobičke, bodisi ga podpirajo, da bi z njegovo pomočjo svoje blago povzdignili v simbol pravilno naravnanega načina življenja; po drugi strani pa je tradicija nacionalne pomembnosti vrhunskih športnih izidov in dosežkov le nekaj krajša od drugih načinov mednarodnega uveljavljanja naroda, pomen športnih dosežkov za dokazovanje življenjske moči naroda pa se lahko kosa s pomenom lestvic, kakršne izdajajo mednarodne finančne ustanove o državah, ali lestvic, na katerih najdemo univerze, razvrščene po njihovi pedagoški in znanstveni moči. Pomembnost športa pa podčrtavajo tudi tisti, ki ga ostro kritizirajo in njegovo sodobno vrhunsko različico odklanjajo kot obliko alienacije, manipulacije in ideologije, saj prav športni spektakularizaciji pripisujejo najvišjo napetost, največji pomen in najotipljivejšo moč nad ljudmi, ki bi se morali bojevati za spremembo svojega družbenega položaja in prevrat v vsej družbeni strukturi, pa jih razvedrila, med katerimi ima šport posebej visoko mesto, uspavajo in pomirjajo prav s tem, da njihovo napetost sproščajo v nenevaren odliv socialne energije. Tega kritičnega vidika sodobnega športa ne kaže omejiti zgolj na vrhunski

  2. ITER diagnostics: Design choices and solutions

    International Nuclear Information System (INIS)

    Costley, A.E.; Sugie, T.; Vayakis, G.; Malaquias, A.; Walker, C.

    2003-01-01

    An extensive diagnostic system will be installed on ITER to provide the measurements necessary to control, evaluate and optimise the plasma performance and to study burning plasma physics. Because of the harsh environment, diagnostic system selection and design has to cope with a range of phenomena not previously encountered in diagnostic implementation. In this paper, we describe the key problems encountered and give examples of the solutions that have been developed. A brief description of the scheme developed for integrating multiple systems into individual ports is also included. We conclude with an assessment of overall system performance. (author)

  3. DIM and diagnostic placement for NIF experiments

    International Nuclear Information System (INIS)

    Kalantar, D.

    1999-01-01

    The input that has been provided on the NIF experiment setup sheets has allowed us to review the diagnostic and DIM placement as well as the baseline unconverted light management plan. We have done an iteration to identify common diagnostic lines of sight, and with additional requirements defined by specific experiments, we propose (1) a baseline plan for DIM placement requiring only five DIMs that may be moved between up to seven DIM ports, and (2) a modified baseline unconverted light management plan. We request additional input to identify primary vs. secondary diagnostics for each experiment definition

  4. TRENDS IN CONTEMPORARY PORT SERVICES MARKETS

    Directory of Open Access Journals (Sweden)

    Hanna Klimek

    2014-12-01

    Full Text Available This article describes the issues associated with functioning of contemporary seaport services markets. The growth of international supply chains, technical progress and the integration processes in shipping, growth of containerization, increasing competition in the seaport services markets and environmental protection regulations make it necessary for port service providers to adapt to the changing expectations and requirements of their customers, both shippers and, especially maritime, carriers. Thus, the activities they undertake are associated with making investments to ensure an adequate capacity to handle cargo, passengers and means of transport, required quality of service, but also with appropriate organization of port supply centres and lead to an improvement of their competitiveness. Both the factors associated with the external and internal environment of seaports affect the changes in the relationship between the supply and demand on port services markets. Contemporary port services markets are characterized by certain phenomena which can be a sign of their adaptation and development. The aim of this article is to present the essence of the port services market and its relationship with the environment, which subject to rapid and significant changes, creates new conditions for the operation of port supply centres and the entire port services market.

  5. Towards Sustainable ASEAN Port Development: Challenges and Opportunities for Vietnamese Ports

    Directory of Open Access Journals (Sweden)

    Saeyeon Roh

    2016-06-01

    Full Text Available Sustainability agendas are challenging port authorities around the world to find ways of operating and managing their ports efficiently and effectively in terms of economic, social, as well as environmental development. In this respect, governments in ASEAN countries have been implementing various green activities seeking to reduce the environmental impact of shipping and related activities. In this connection, most studies in the existing literature mainly focus on the environmental aspects of sustainable development and have not clearly explained what sustainable port development exactly entails. Furthermore, most of these studies emphasized on the impact of port development and overlooked what factors influence sustainable port development. To address these gaps, this research aim to explore the main factors shaping sustainable port development. This was conducted through a comprehensive review of related literature as well as confirmatory in-depth interviews with port authorities. As a result, findings from this research would help identify key elements of sustainable port development from port authorities’ perspective. The challenges, opportunities and managerial implications for Vietnamese ports are also discussed accordingly.

  6. Optimal control of a repowered vehicle: Plug-in fuel cell against plug-in hybrid electric powertrain

    Energy Technology Data Exchange (ETDEWEB)

    Tribioli, L., E-mail: laura.tribioli@unicusano.it; Cozzolino, R. [Dept. of Industrial Engineering, University of Rome Niccolo’ Cusano (Italy); Barbieri, M. [Engineering Dept., University of Naples Parthenope, Centro Direzionale-Isola C4, 80143 Naples (Italy)

    2015-03-10

    This paper describes two different powertrain configurations for the repowering of a conventional vehicle, equipped with an internal combustion engine (ICE). A model of a mid-sized ICE-vehicle is realized and then modified to model both a parallel plug-in hybrid electric powertrain and a proton electrolyte membrane (PEM) fuel cell (FC) hybrid powertrain. The vehicle behavior under the application of an optimal control algorithm for the energy management is analyzed for the different scenarios and results are compared.

  7. Optimal control of a repowered vehicle: Plug-in fuel cell against plug-in hybrid electric powertrain

    International Nuclear Information System (INIS)

    Tribioli, L.; Cozzolino, R.; Barbieri, M.

    2015-01-01

    This paper describes two different powertrain configurations for the repowering of a conventional vehicle, equipped with an internal combustion engine (ICE). A model of a mid-sized ICE-vehicle is realized and then modified to model both a parallel plug-in hybrid electric powertrain and a proton electrolyte membrane (PEM) fuel cell (FC) hybrid powertrain. The vehicle behavior under the application of an optimal control algorithm for the energy management is analyzed for the different scenarios and results are compared

  8. Enabling information sharing in a port

    DEFF Research Database (Denmark)

    Olesen, Peter Bjerg; Hvolby, Hans-Henrik; Dukovska-Popovska, Iskra

    2012-01-01

    Ports are integral parts of many supply chains and are as such a contributing factor to the overall efficiency of the supply chain. Ports are also dynamic entities where things changes continuously. The dynamic nature of ports is also a problem when trying to optimise the utilisation of resources...... and ensure a low lead-time. Information sharing is a very important tool to reduce the effect of dynamism. This paper attempts to explain how information sharing is enabled in such an environment, and which considerations are relevant, both in regards to the information and required technology. The paper...

  9. Dialysis grafts arterial plug: Retrieval using the tulip sheath device in vitro

    International Nuclear Information System (INIS)

    Sharafuddin, Melhem J.; Titus, Jack L.; Gu Xiaoping; Hunter, David W.; Amplatz, Kurt

    1997-01-01

    The 'arterial plug' is a resistant thrombus that frequently persists at the arterial anastomosis of clotted hemodialysis grafts following thrombolytic therapy. We studied the physical and morphological characteristics of the plug and determined the feasibility of transcatheter removal in vitro using the tulip compression thrombectomy system. Sixteen thrombus plugs were recovered during surgical thrombectomy of clotted human dialysis grafts. The physical and gross physical characteristics of all plugs were analyzed. Eight specimens were evaluated microscopically. Transcatheter compression thrombectomy of eight plugs was attempted in vitro. Each plug was embedded in a polyvinyl tube filled with newly clotted blood and connected to a flow circuit. First, balloon-assisted aspiration thrombectomy (BAT) of soft thrombus was performed, while sparing the distal-most segment containing the plug. The tulip sheath was then introduced facing the 'arterial end' of the tube. The thrombus segment containing the plug was pulled back into the tulip mesh using either a 3 Fr Fogarty balloon catheter or a self-expanding rake. The tulip was closed to compress and remove the trapped plug. Near-complete thrombectomy of soft clot was achieved in all tested tubes. Compression and retrieval of the entire arterial plug was successful in all except one, where only partial compression of the plug occurred, presumably due to fibrotic changes. No fragmentation or embolization occurred in the remaining procedures. Spongy consistency was noted in 94% of the specimens. Microscopic evaluation showed organized layered thrombus with compaction in five plugs. Transcatheter removal of a thrombus plug is feasible in vitro using the tulip compression-thrombectomy system

  10. Assesment of port governance in Brazil: a managerial perspective on the port of Santos

    OpenAIRE

    Almeida, José Eduardo Costa de

    2015-01-01

    The role of maritime transportation within international trade was drastically revamped during the inception of the globalization process, which enhanced the contribution of ports in world economy as main logistics gateways for global production and trade. As a result, the relationship between ports and governments has changed. Devolution ideologies that had been applied in other industries decades ago were now being considered by governments for the port industry. Many central governments so...

  11. Algorithms for Port-of-Entry Inspection

    National Research Council Canada - National Science Library

    Roberts, Fred S

    2007-01-01

    .... The percentage at some ports has now risen to 6%, but this is still a very small percentage. The purpose of this project was to develop decision support algorithms that help to optimally intercept illicit materials and weapons...

  12. Port: arstid kasutavad narkootikume / Marina Lohk

    Index Scriptorium Estoniae

    Lohk, Marina

    2015-01-01

    Tallinna ülikooli terviseteaduste ja spordi instituudi direktor ja spordibioloog Kristjan Port mainis ETV saates "Vabariigi kodanikud", et töövõime taastamiseks kasutatakse sageli narkootilisi aineid ning seda teevad ka arstid. Kristjan Porti selgitused

  13. Port Authority of Allegheny County Transit Stops

    Data.gov (United States)

    Allegheny County / City of Pittsburgh / Western PA Regional Data Center — All transit stops within the Port Authority of Allegheny County's service area for the November 20, 2016 - March (TBD) 2017 schedule period.

  14. Grain operator miffed at port administration

    Index Scriptorium Estoniae

    2006-01-01

    Ventspils Grain Terminal saatis president Vaira Vike-Freibergale ja mitmetele ministritele kirja sõnumiga, et Ventspilsi Vabasadama (Ventspils Free Port) administratsiooni tegevus takistab terminali äritegevust

  15. Tamralipti: The ancient port of India

    Digital Repository Service at National Institute of Oceanography (India)

    Tripati, S.; Rao, S.R.

    20', 87 degrees 55') east coast of India. Other ports of Bengal, such as Satgaon and Sonargaon were also having overseas contacts with Ceylone, Java and Sumatra. In this paper, an attempt is made to synthesize archaeological, literary, epigraphic...

  16. Public Port Finance Survey for FY 2006

    Science.gov (United States)

    2008-12-01

    This report is the result of a cooperative effort between the Maritime Administration and : the American Association of Port Authorities (AAPA). It was prepared by the Maritime : Administration, using financial information furnished by AAPA. : This i...

  17. Variable Delay in port-Hamiltonian Telemanipulation

    NARCIS (Netherlands)

    Secchi, C; Stramigioli, Stefano; Fantuzzi, C.

    2006-01-01

    In several applications involving bilateral telemanipulation, master and slave act at different power scales. In this paper a strategy for passively dealing with variable communication delay in scaled port-Hamiltonian based telemanipulation over packet switched networks is proposed.

  18. An Analysis of Port Service Quality and Customer Satisfaction: The Case of Korean Container Ports

    Directory of Open Access Journals (Sweden)

    Gi Tae Yeo

    2015-12-01

    Full Text Available Ports play a critical role in the economy of many countries and regions. Failure or unreliability of port services can significantly influence port customers—shipping lines and cargo owners—and result in their dissatisfaction. However, what constitutes port service quality (PSQ and its influence on the satisfaction of port customers has not been well investigated in the literature. Therefore, this study investigates the concept of PSQ and its influence on customer satisfaction in the case of Korean container ports. Following a literature review, a conceptual model of PSQ and its influence on customer satisfaction is proposed. The model was validated through a survey of 313 members of the Korean Port Logistics Association (KPLA. Partial least squares structural equation modeling (PLS-SEM was conducted to confirm the PSQ dimensions and to examine their relationship with customer satisfaction using SmartPLS 3.2.1 software. PSQ is found to be a five-factor construct, and its management, and image and social responsibility factors have significant positive effects on customer satisfaction. In addition to its academic contribution, this study also contributes to management practices because port managers can use the PSQ scale to measure their customers’ satisfaction and justify investments in the quality management of port services.

  19. Managing Risks in Dry Port Operations

    OpenAIRE

    Ciortescu Cezar-Gabriel; Pãvãla?cu Narcis Sebastian

    2012-01-01

    The purpose of this paper is to have an in-depth look into the phenomenon of risk assessment and risk management strategies in managing dry port operations as an integrated part into international containerized freight trade. The fact that world crises take the form of disruptions, bankruptcies, breakdowns, macroeconomic and political changes, and disasters leads to higher risks and makes risk management more and more difficult. This paper aims to discuss the theory behind the dry port concep...

  20. Research for Foreign Advanced Ports for Protection and Development Experience

    Science.gov (United States)

    Zhang, Lu; Tian, Mingjing; Zhao, Junjie; Shou, Youping; Wang, Ning; Qiao, Jianzhe; Li, Guanglou

    2018-04-01

    Into the twenty-first century, the process globalization of economic and trade is getting faster and faster, As of 2014, China's annual port trading amount topped the world, But in the port of environmental protection sustainable development approach with foreign advanced port environmental management concept has a big gap. Combined with the present situation of modern ports in China. Drawing lessons from foreign advanced environmental protection idea of port, in order to promote the protection of port environment in our country. The experience of protection and development of foreign advanced port environment will be discussed and discussed.

  1. Preparation and Characterization of Chemical Plugs Based on Selected Hanford Waste Simulants

    International Nuclear Information System (INIS)

    Mattigod, Shas V.; Wellman, Dawn M.; Parker, Kent E.; Cordova, Elsa A.; Gunderson, Katie M.; Baum, Steven R.; Crum, Jarrod V.; Poloski, Adam P.

    2008-01-01

    This report presents the results of preparation and characterization of chemical plugs based on selected Hanford Site waste simulants. Included are the results of chemical plug bench testing conducted in support of the M1/M6 Flow Loop Chemical Plugging/Unplugging Test (TP-RPP-WTP-495 Rev A). These results support the proposed plug simulants for the chemical plugging/ unplugging tests. Based on the available simulant data, a set of simulants was identified that would likely result in chemical plugs. The three types of chemical plugs that were generated and tested in this task consisted of: 1. Aluminum hydroxide (NAH), 2. Sodium aluminosilicate (NAS), and 3. Sodium aluminum phosphate (NAP). While both solvents, namely 2 molar (2 M) nitric acid (HNO3) and 2 M sodium hydroxide (NaOH) at 60 C, used in these tests were effective in dissolving the chemical plugs, the 2 M nitric acid was significantly more effective in dissolving the NAH and NAS plugs. The caustic was only slightly more effecting at dissolving the NAP plug. In the bench-scale dissolution tests, hot (60 C) 2 M nitric acid was the most effective solvent in that it completely dissolved both NAH and NAS chemical plugs much faster (1.5 - 2 x) than 2 M sodium hydroxide. So unless there are operational benefits for the use of caustic verses nitric acid, 2 M nitric acid heated to 60 C should be the solvent of choice for dissolving these chemical plugs. Flow-loop testing was planned to identify a combination of parameters such as pressure, flush solution, composition, and temperature that would effectively dissolve and flush each type of chemical plug from preformed chemical plugs in 3-inch-diameter and 4-feet-long pipe sections. However, based on a review of the results of the bench-top tests and technical discussions, the Waste Treatment Plant (WTP) Research and Technology (R and T), Engineering and Mechanical Systems (EMS), and Operations concluded that flow-loop testing of the chemically plugged pipe sections

  2. Occupational hazards to health of port workers.

    Science.gov (United States)

    Wang, Yukun; Zhan, Shuifen; Liu, Yan; Li, Yan

    2017-12-01

    The aim of this article is to reduce the risk of occupational hazards and improve safety conditions by enhancing hazard knowledge and identification as well as improving safety behavior for freight port enterprises. In the article, occupational hazards to health and their prevention measures of freight port enterprises have been summarized through a lot of occupational health evaluation work, experience and understanding. Workers of freight port enterprises confront an equally wide variety of chemical, physical and psychological hazards in production technology, production environment and the course of labor. Such health hazards have been identified, the risks evaluated, the dangers to health notified and effective prevention measures which should be put in place to ensure the health of the port workers summarized. There is still a long way to go for the freight port enterprises to prevent and control the occupational hazards. Except for occupational hazards and their prevention measures, other factors that influence the health of port workers should also be paid attention to, such as age, work history, gender, contraindication and even the occurrence and development rules of occupational hazards in current production conditions.

  3. Classification and prediction of port variables

    Energy Technology Data Exchange (ETDEWEB)

    Molina Serrano, B.

    2016-07-01

    Many variables are included in planning and management of port terminals. They can beeconomic, social, environmental and institutional. Agent needs to know relationshipbetween these variables to modify planning conditions. Use of Bayesian Networks allowsfor classifying, predicting and diagnosing these variables. Bayesian Networks allow forestimating subsequent probability of unknown variables, basing on know variables.In planning level, it means that it is not necessary to know all variables because theirrelationships are known. Agent can know interesting information about how port variablesare connected. It can be interpreted as cause-effect relationship. Bayesian Networks can beused to make optimal decisions by introduction of possible actions and utility of theirresults.In proposed methodology, a data base has been generated with more than 40 port variables.They have been classified in economic, social, environmental and institutional variables, inthe same way that smart port studies in Spanish Port System make. From this data base, anetwork has been generated using a non-cyclic conducted grafo which allows for knowingport variable relationships - parents-children relationships-. Obtained network exhibits thateconomic variables are – in cause-effect terms- cause of rest of variable typologies.Economic variables represent parent role in the most of cases. Moreover, whenenvironmental variables are known, obtained network allows for estimating subsequentprobability of social variables.It has been concluded that Bayesian Networks allow for modeling uncertainty in aprobabilistic way, even when number of variables is high as occurs in planning andmanagement of port terminals. (Author)

  4. Erosion on spark plug electrodes; Funkenerosion an Zuendkerzenelektroden

    Energy Technology Data Exchange (ETDEWEB)

    Rager, J.

    2006-07-01

    Durability of spark plugs is mainly determined by spark gap widening, caused by electrode wear. Knowledge about the erosion mechanisms of spark plug materials is of fundamental interest for the development of materials with a high resistance against electrode erosion. It is therefore crucial to identify those parameters which significantly influence the erosion behaviour of a material. In this work, a reliable and reproducible testing method is presented which produces and characterizes electrode wear under well-defined conditions and which is capable of altering parameters specifically. Endurance tests were carried out to study the dependence of the wear behaviour of pure nickel and platinum on the electrode temperature, gas, electrode gap, electrode diameter, atmospheric pressure, and partial pressure of oxygen. It was shown that erosion under nitrogen is negligible, irrespective of the material. This disproves all common mechanism discussed in the literature explaining material loss of spark plug electrodes. Based on this observation and the variation of the mentioned parameters a new erosion model was deduced. This relies on an oxidation of the electrode material and describes the erosion of nickel and platinum separately. For nickel, electrode wear is caused by the removal of an oxide layer by the spark. In the case of platinum, material loss occurs due to the plasma-assisted formation and subsequent evaporation of volatile oxides in the cathode spot. On the basis of this mechanism a new composite material was developed whose erosion resistance is superior to pure platinum. Oxidation resistant metal oxide particles were added to a platinum matrix, thus leading to a higher erosion resistance of the composite. However, this can be decreased by a side reaction, the separation of oxygen from the metal oxides, which effectively assists the oxidation of the matrix. This reaction can be suppressed by using highly stable oxides, characterized by a large negative Gibbs

  5. Component sizing optimization of plug-in hybrid electric vehicles

    International Nuclear Information System (INIS)

    Wu, Xiaolan; Cao, Binggang; Li, Xueyan; Xu, Jun; Ren, Xiaolong

    2011-01-01

    Plug-in hybrid electric vehicles (PHEVs) are considered as one of the most promising means to improve the near-term sustainability of the transportation and stationary energy sectors. This paper describes a methodology for the optimization of PHEVs component sizing using parallel chaos optimization algorithm (PCOA). In this approach, the objective function is defined so as to minimize the drivetrain cost. In addition, the driving performance requirements are considered as constraints. Finally, the optimization process is performed over three different all electric range (AER) and two types of batteries. The results from computer simulation show the effectiveness of the approach and the reduction in drivetrian cost while ensuring the vehicle performance.

  6. A study on thimble plug removal for PWR plants

    Energy Technology Data Exchange (ETDEWEB)

    Song, Dong Soo; Lee, Chang Sup; Lee, Jae Yong; Jun, Hwang Yong [Korea Electric Power Research Institute, Taejon (Korea, Republic of)

    1997-12-31

    The thermal-hydraulic effects of removing the RCC guide thimble plugs are evaluated for 8 Westinghouse type PWR plants in Korea as a part of feasibility study: core outlet loss coefficient, thimble bypass flow, and best estimate flow. It is resulted that the best estimate thimble bypass flow increases about by 2% and the best estimate flow increases approximately by 1.2%. The resulting DNBR penalties can be covered with the current DNBR margin. Accident analyses are also investigated that the dropped rod transient is shown to be limiting and relatively sensitive to bypass flow variation. 8 refs., 5 tabs. (Author)

  7. The viscoelastic properties of the cervical mucus plug

    DEFF Research Database (Denmark)

    Bastholm, Sara K.; Becher, Naja; Stubbe, Peter Reimer

    2014-01-01

    labor. MethodsViscoelastic properties of CMPs were investigated with a dynamic oscillatory rheometer using frequency and stress sweep experiments within the linear viscoelastic region. Main outcome measuresThe rheological variables obtained were as follows: elastic modulus (G), viscous modulus (G......ObjectiveTo characterize the viscoelastic properties of cervical mucus plugs (CMPs) shed during labor at term. DesignExperimental research. SettingDepartment of Obstetrics and Gynecology, Aarhus University Hospital, Denmark. Population/SampleSpontaneously shed CMPs from 18 healthy women in active...

  8. A study on thimble plug removal for PWR plants

    Energy Technology Data Exchange (ETDEWEB)

    Song, Dong Soo; Lee, Chang Sup; Lee, Jae Yong; Jun, Hwang Yong [Korea Electric Power Research Institute, Taejon (Korea, Republic of)

    1998-12-31

    The thermal-hydraulic effects of removing the RCC guide thimble plugs are evaluated for 8 Westinghouse type PWR plants in Korea as a part of feasibility study: core outlet loss coefficient, thimble bypass flow, and best estimate flow. It is resulted that the best estimate thimble bypass flow increases about by 2% and the best estimate flow increases approximately by 1.2%. The resulting DNBR penalties can be covered with the current DNBR margin. Accident analyses are also investigated that the dropped rod transient is shown to be limiting and relatively sensitive to bypass flow variation. 8 refs., 5 tabs. (Author)

  9. Plug-and-Play Control – Modifying Control Systems Online

    DEFF Research Database (Denmark)

    Bendtsen, Jan Dimon; Trangbæk, K; Stoustrup, Jakob

    2013-01-01

    Often, when new sensor or actuator hardware be- comes available for use in a control system, it is desirable to retain the existing control system and apply the new control capabilities in a gradual fashion rather than decommissioning the entire existing system and replacing it with an altogether...... new control system. However, this requires that the existing controller remains in action, and the new control law component is added to the existing system. This paper formally introduces the concept of Plug-and-Play control and proposes two different methods of introducing new control components...

  10. Plug and Play Firms in the TNCs' Virtual Value Chain

    Directory of Open Access Journals (Sweden)

    Teresa Pakulska

    2016-04-01

    Full Text Available Growing virtualisation of the value chain appears to be an expression of implementation of ICT solutions in international business represented by TNCs. This creates new opportunities for cooperation within the value chain and its composition. The growing importance in this area can be attributed to companies integrating the value chain, known as plug and play. Their integration into the value creation chain gives a new dimension to TNCs' strategic choices from the fragmentation of activity and its integration on an international scale point of view.

  11. Plug-In Hybrid Vehicle Analysis (Milestone Report)

    Energy Technology Data Exchange (ETDEWEB)

    Markel, T.; Brooker, A.; Gonder, J.; O' Keefe, M.; Simpson, A.; Thornton, M.

    2006-11-01

    NREL's plug-in hybrid electric vehicle (PHEV) analysis activities made great strides in FY06 to objectively assess PHEV technology, support the larger U.S. Department of Energy PHEV assessment effort, and share technical knowledge with the vehicle research community and vehicle manufacturers. This report provides research papers and presentations developed in FY06 to support these efforts. The report focuses on the areas of fuel economy reporting methods, cost and consumption benefit analysis, real-world performance expectations, and energy management strategies.

  12. Compact Fluorescent Plug-In Ballast-in-a-Socket

    Energy Technology Data Exchange (ETDEWEB)

    Rebecca Voelker

    2001-12-21

    The primary goal of this program was to develop a ballast system for plug-in CFLs (compact fluorescent lamps) that will directly replace standard metal shell, medium base incandescent lampholders (such as Levition No. 6098) for use with portable lamp fixtures, such as floor, table and desk lamps. A secondary goal was to identify a plug-in CFL that is optimized for use with this ballast. This Plug-in CFL Ballastin-a-Socket system will allow fixture manufacturers to easily manufacture CFL-based high-efficacy portable fixtures that provide residential and commercial consumers with attractive, cost-effective, and energy-efficient fixtures for use wherever portable incandescent fixtures are used today. The advantages of this proposed system over existing CFL solutions are that the fixtures can only be used with high-efficacy CFLs, and they will be more attractive and will have lower life-cycle costs than screw-in or adapter-based CFL retrofit solutions. These features should greatly increase the penetration of CFL's into the North American market. Our work has shown that using integrated circuits it is quite feasible to produce a lamp-fixture ballast of a size comparable to the current Edison-screw 3-way incandescent fixtures. As for price points for BIAS-based fixtures, end-users polled by the Lighting Research Institute at RPI indicated that they would pay as much as an additional $10 for a lamp containing such a ballast. The ballast has been optimized to run with a 26 W amalgam triple biax lamp in the base-down position, yet can accept non-amalgam versions of the lamp. With a few part alterations, the ballast can be produced to support 32 W lamps as well. The ballast uses GE's existing L-Comp[1] power topology in the circuit so that the integrated circuit design would be a design that could possibly be used by other CFL and EFL products with minor modifications. This gives added value by reducing cost and size of not only the BIAS, but also possibly other

  13. Experiment on thermal insulation and sodium deposition of shield plug

    International Nuclear Information System (INIS)

    Hashiguchi, K.; Honda, M.; Shiratori, H.; Ozaki, O.; Suzuki, M.

    1986-01-01

    A series of experiments on temperature distribution and thermal insulation characteristics was conducted using a reduced scale model of LMFBR shield plug. Observation and measurement of sodium deposition were also conducted on the model after the experiment. The effect of annulus natural convection was clarified for temperature and the thermal insulation characteristics from evaluating the result. Temperature distribution analysis was conducted successfully by combining the general purpose structural analysis program NASTRAN and vertical annulus natural convection analysis program VANAC. Moreover, significant effect was substantiated for the annulus convection barrier to increase the thermal insulation performance, narrow horizontal gap structure to prevent sodium deposition and thermal insulation plates. (author)

  14. Specification for high voltage cable plug and socket connections for medical X-ray equipment

    International Nuclear Information System (INIS)

    1980-01-01

    Under the direction of the Light Engineering Standards Committee, a British Standard Specification has been prepared for three-conductor and four-conductor high-voltage cable plug and socket connections for medical X-ray equipment. The standard deals with the essential dimensions to ensure mechanical interchangeability, the recommended dimensions, the wiring connections to contacts of plug and socket and the marking of contacts of plug and socket. (U.K.)

  15. Plugging wells for abandonment: a state-of-the-art study and recommended procedures

    International Nuclear Information System (INIS)

    Herndon, J.; Smith, D.K.

    1976-09-01

    The state-of-the-art of borehole plugging of abandoned oil wells and the tools and materials used are discussed. Special problems encountered are considered and several case studies are outlined. The special procedures which must be followed if the plugged borehole is to be considered as a repository for radioactive wastes are discussed and special recommendations are made. A state-by-state summary is given of the regulatory requirements for borehole plugging

  16. Inland Ports in the Republic of Croatia: Approvals for Port Activities instead of Concessions

    Directory of Open Access Journals (Sweden)

    Goran Vojković

    2008-11-01

    Full Text Available According to the 1998 Act on Inland Ports, the right to performall port activities within inland ports of the Republic ofCroatia is given on the basis of concession, obtained throughbidding. It has been noticed in practice that modem businessprocesses and traffic flows are more dynamic than before whenclassic concession relations were created. Also, types andamounts of cargo are changing every couple of years, which isfollowed by quick adjustments, instead of working according torigid and long-term defined decisions and concession contracts.Furthermore, the practice has shown for some activitiesthat the number of port providers (such as ship suppliers,port-agency and freight forwarders should not be limited. Thismeans that the system of a limited number of port providers isimportant only for the activities that require location within aport, as the port area is physically limited. Therefore, the newAct on Navigation and Inland Ports from 2007, whose framehas been completed by sub-law acts during 2008, has replacedthe complex concession system for performing activities in inlandports by a more liberal approval system. On the basis ofthese, higher dynamics of work of port providers is enabled aswell as easier adjustment to market conditions. Furthermore,the main limitation factor that determines the number of portusers becomes the available physical space within a port, whichprovides undisturbed competition, along with larger offer ofport services that do not require that space. It is also importantto point out that the new Act specifically includes distributionand cargo logistics, also processing and improvement of goodsas well as industrial activities including production that enablecomplete economic utilization of port capacities into the existingport activities, thus significantly changing the role of the portitself as a logistic centre.

  17. Fiscal year 1996 well plugging and abandonment program Y-12 Plant, Oak Ridge, Tennessee

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-04-01

    This report is a synopsis of the progress of the well plugging and abandonment program at the Oak Ridge Y-12 Plant, Oak Ridge, Tennessee, from August 1995 through August 1996. A total of 27 wells, piezometers, and borings were plugged and abandoned during the period of time covered in this report. All wells and borings were plugged and abandoned in accordance with the Monitoring Well Plugging and Abandonment Plan for the U.S. Department of Energy, Y-12 Plant, Oak Ridge, Tennessee (HSW, Inc. 1991).

  18. Hydrological responses to channelization and the formation of valley plugs and shoals

    Science.gov (United States)

    Pierce, Aaron R.; King, Sammy L.

    2017-01-01

    Rehabilitation of floodplain systems focuses on restoring interactions between the fluvial system and floodplain, however, there is a paucity of information on the effects of valley plugs and shoals on floodplain hydrological processes. We investigated hydrologic regimes in floodplains at three valley plug sites, two shoal sites, and three unchannelized sites. Valley plug sites had altered surface and sub-surface hydrology relative to unchannelized sites, while only sub-surface hydrology was affected at shoal sites. Some of the changes were unexpected, such as reduced flood duration and flood depth in floodplains associated with valley plugs. Our results emphasize the variability associated with hydrologic processes around valley plugs and our rudimentary understanding of the effects associated with these geomorphic features. Water table levels were lower at valley plug sites compared to unchannelized sites, however, valley plug sites had a greater proportion of days when water table inundation was above mean root collar depth than both shoal and unchannelized sites as a result of lower root collar depths and higher deposition rates. This study has provided evidence that valley plugs can affect both surface and sub-surface hydrology in different ways than previously thought and illustrates the variability in hydrological responses to valley plug formation.

  19. Borehole plugging of man-made accesses to a basalt repository: a preliminary study

    International Nuclear Information System (INIS)

    Taylor, C.L.; Anttonen, G.J.; O'Rourke, J.E.; Niccum, M.R.

    1979-09-01

    This report describes the status of work currently in progress for the Basalt Borehole Plugging Program (BBPP). The primary objectives of the BBPP outlined in this report have been met during this first phase of work. These objectives included: (1) the preparation of a preliminary list of candidate plug materials; (2) a description of available machinery capable of placing candidate plug materials; and (3) the development of physical and geochemical testing programs to help evaluate the chemical stability and physical properties of candidate plug materials. The most significant finding from work to date is that given reasonable regulatory criteria, nothing has been identified which would prevent design of a plug system to seal manmade openings leading to a nuclear waste repository in Columbia River basalt for significantly long periods of time (on the order of thousands of years). Work accomplished to date indicates that this plug system can be designed using both natural and manufactured materials and can be emplaced with existing placement machinery and modifications of that machinery. The objectives of Task II are to conduct laboratory tests to evaluate the suitability of preferred candidate materials for plugging boreholes in the proposed repository, select plug system(s), initiate preconceptual machinery design for the placement of materials in plug system(s), and prepare a preliminary Task II report. As with Task I project organization, Task II is divided into subtasks that are identified by written subtask work summaries

  20. A Comparison of the Predicted Tube Plugging Rate for Alloy 600HTMA Steam Generator

    Energy Technology Data Exchange (ETDEWEB)

    Boo, Myung Hwan; Kang, Yong Seok [Korea Hydro and Nuclear Power Co., Daejeon (Korea, Republic of)

    2010-10-15

    To manage components that are used in long term operations such as steam generation, it is important to know the tube plugging rate, which can cause the performance degradation. The life of components can be predicted by the method using determinism and probability theory. With a method using probability theory, damage prediction of tube is possible. In this study, damage prediction for steam generation (SG) tube is performed using Weibull distribution and predicted plugging rate (life) is compared with the simple sum plugging number and case by case (failure cause) plugging number

  1. Apparatus for sealing a rotatable shield plug in a liquid metal nuclear reactor

    International Nuclear Information System (INIS)

    Winkleblack, R.K.

    1980-01-01

    An apparatus for sealing a rotatable shield plug in a nuclear reactor having liquid metal coolant is described. The apparatus includes a dip -ring seal adapted to provide a fluid barrier between the liquid metal and the atmosphere and to permit rotation of the shield plug. The apparatus also includes a static seal for the rotatable shield plug located between the dip-ring seal and the liquid metal. The static seal isolates the dip-ring seal from the liquid metal vapor during operation at power and can be disengaged for rotation of the shield plug

  2. Combustion aided by a glow plug in diesel engines under cold idling conditions

    OpenAIRE

    Li, Qile

    2016-01-01

    Glow plugs are widely used to promote the desired cold start and post-cold start combustion characteristics of light duty diesel engines. The importance of the glow plug becomes more apparent when the compression ratio is low. An experimental investigation of combustion initiation and development aided by the glow plug has been carried out on a single cylinder HPCR DI diesel engine with a low compression ratio of 15.5:1. High speed imaging of combustion initiated by the glow plug in a combust...

  3. Potential formation in the plasma confinement region of a radio-frequency plugged linear device

    International Nuclear Information System (INIS)

    Fujita, Hideki; Kumazawa, Ryuhei; Howald, A.M.; Okamura, Shoichi; Sato, Teruyuki; Adati, Keizo; Garner, H.R.; Nishimura, Kiyohiko.

    1987-08-01

    Plasma potential formation in an open-ended plasma confinement system with RF plugging (the RFC-XX-M device) is investigated. The plasma potential in the central confinement region is measured with a heavy ion beam probe system and potentials at the RF plug section are measured with multi-grid energy analyzers. The measured plasma potential is compared with that deduced from the generalized Pastukhov formula. Results show that the plasma potential develops as an ambipolar potential to equate ion and electron end losses. During RF plugging, electrons are heated by Landau damping, while ions are not heated since adiabatic conditions apply during ion plugging in this experiment. (author)

  4. Reconstitutable control assembly having removable control rods with detachable split upper end plugs

    International Nuclear Information System (INIS)

    Gjertsen, R.K.; Knott, R.P.; Sparrow, J.A.

    1989-01-01

    This patent describes, in a reconstitutable control assembly for use with a nuclear fuel assembly, the control assembly including a spider structure and at least one control rod, an attachment joint for detachable fastening the control rod to the spider structure. The attachment joint comprising: a hollow connecting finger on the spider structure; and an elongated detachable split upper end plug on the control rod having a pair of separate upper and lower plug portions, the upper plug portion having integrally-connected tandemly- arranged upper, middle and lower sections. The lower plug portion having integrally-connected tandemly-arranged upper, middle and lower segments

  5. Development of expanded type plugging technique for leaky tubes of steam generators of Indian PHWRs

    International Nuclear Information System (INIS)

    Das, Nirupam; Samuel, K.A.; Joemon, V.; Rupani, B.B.

    2006-01-01

    Steam generators are very important component of Nuclear Power Plant (NPP), as they are part of Primary Heat Transport (PHT) system of Pressurised Heavy Water Reactors (PHWRs). A nuclear power plant of 220 MWe capacity has four mushroom type steam generators, each consisting of 1830 U-tubes (16 mm outside diameter and 1 mm wall thickness) made of Incoloy-800 material. The tubes of 'tube and shell type steam generator' act as the pressure boundary of PHT System. Any structural failure of these tubes may lead to release of radioactivity along with plant outage and significant economic loss. Hence, it is necessary to plug the leaky tubes for continued and safe operation of a steam generator. An expanded type plugging technique has been developed at Reactor Engineering Division to plug the leaky tubes. This plugging technique is selected because of low residual stress imparted in the adjacent 'tube to tube-sheet' joints. This plug meets the various codal requirements of steam generator. A number of qualification trials have been carried out with such plugs in the mock up facility. The expanded plugs meet the design requirements for pull out strength and leak-tightness. This paper describes the design concept of the plug, developmental aspects and qualification of the plugging technique. (author)

  6. PHACE syndrome misdiagnosed as a port-wine stain.

    Science.gov (United States)

    Thomson, Jason; Greig, Aina; Lloyd, Claire; Morrison, Danny; Flohr, Carsten

    2015-07-15

    We present the case of a boy born with a large macular, segmental vascular anomaly over the left face, initially diagnosed as a capillary malformation (port-wine stain) by the postnatal paediatric team. The vascular anomaly in the face then grew rapidly during the first few weeks of life and started to occlude the left eye, causing parental concerns about the infant's vision. A dermatological opinion established that the lesion was a segmental infantile haemangioma (IH). This, in combination with the posterior fossa malformation previously detected on antenatal scanning and confirmed by an MRI postnatally, satisfied the criteria for Posterior fossa abnormalities, Haemangiomas, Arterial abnormalities, Cardiac abnormalities and Eye abnormalities (PHACE) syndrome: a rare cutaneous neurovascular syndrome. This case highlights the diagnostic challenge posed by early phenotypes of haemangiomas as well as the importance of correctly diagnosing PHACE syndrome. 2015 BMJ Publishing Group Ltd.

  7. The aspects regarding plugging the defective tubes of the steam generator using plastic deformation of the plug wall by conventional or unconventional techniques

    International Nuclear Information System (INIS)

    Gyongyosi, Tiberiu

    2006-01-01

    After a brief introduction the advantages and disadvantages of two plugging methods of the defective tubes from steam generator by plastic deformation of the wall of the plug, deformation performed by mechanical rolling (conventional technique) and by electrohydraulic shock (unconventional technique), respectively, are showed. The paper gives the results of the experimental tests to install the plugs at the end of the tube having the same geometry with those of the steam generator, the performance reached in this stage and some conclusions in the end

  8. Application of Game Theory and Uncertainty Theory in Port Competition between Hong Kong Port and Shenzhen Port

    Directory of Open Access Journals (Sweden)

    Thi Minh Hoang Do

    2015-06-01

    Full Text Available This paper unveils the strong competition in container cargo between Hong Kong Port which has been emerging as an international maritime center since the 1970s and Shenzhen Port which has recently gained remarkable achievements in the Pearl River Delta region. Among various competing strategies, the study focuses on the long-term one in which two ports will decide to compete by investing in capacity. The purpose of this research is to examine their decision making process and to suggest future strategic actions in the current situation. Within its scope, only economic profit brought back from the investment is considered. For this reason, an uncertain payoff two-person game model is developed where an uncertain factor of demand is involved. In applying Uncertainty theory (Liu, 2013, the two methods to solve the game are introduced, including uncertain statistics and the expected Nash Equilibrium strategy. The results obtained from this research generate meaningful suggestions for future competition plan for the two selected ports, which conclude that Shenzhen is the dominant port in this long-term strategy. Compared to existing works on the same topic, the paper shows its distinctiveness by studying the latest competitive situation with regard to the uncertain demand in the game model.

  9. Adaptive Port Planning under Disruptive Trends with focus on the case of The Port of Kuala Tanjung, Indonesia

    OpenAIRE

    Prakoso Andre; Taneja Poonam; Velinga Tiedo

    2018-01-01

    As a national strategic project, the Port of Kuala Tanjung draws significant attention at national and international level. Considering the semi-greenfield nature of the port, the diverse set of stakeholders, and the prevailing disruptive trends in the world port business, a robust first-phase port layout is required to kick-start the project and guarantee the overall sustainability of the port development. The objective of this research is to identify any uncertain or disruptive trends, both...

  10. Management of Artisanal Fishing Port: a Case Study on Labuhanhaji Fishing Port, South Aceh Regency, Aceh Province

    OpenAIRE

    NurJannah, Betri; ', Syaifuddin; Zain, Jonny

    2014-01-01

    A series survey activity was carried out for evaluating management function atlabuanhaji fishing port, South Aceh regency. This research was emphasis on planning, organizing, action and controlling at management pattern of labuhanhaji fishing port. The facilities of fishing port data and daily activities description of staff at labuhanhaji fishing port was used as additional information and consideration in management of labuhanhaji fishing port. Lack of good management was impact on staff an...

  11. The Re-Conceptualization of the Port Supply Chain as a Smart Port Service System: The Case of the Port of Salerno

    Directory of Open Access Journals (Sweden)

    Antonio Botti

    2017-04-01

    Full Text Available This paper proposes a re-conceptualization of the port supply chain as a smart service system, in accordance with the theory of service science. Starting from a short literature review about the port supply chain approach and service science, a new comprehensive framework is provided to better understand seaport dynamics and the creation of competitive port supply chains. The methodology used is the case study approach. The Authors examined the Port of Salerno (Italy and re-conceptualized it as a smart port service system. The originality of the work lies in the application of service science as a lens to re-conceptualize the port supply chain, that allows the implementation of a logistic framework. Both theoretical and practical implications are provided to enrich the literature about port supply chains and to support port operators.

  12. Petrographic study of core plugs from lower goru sandstones

    International Nuclear Information System (INIS)

    Memon, M.K.; Tunio, A.; Leghari, A.

    2008-01-01

    Petrographic rock type description is a fundamental component in the reservoir description processes and typically included measurement to identify sediment source, texture, composition and mineralogy. Petroleum workers have long used the Petrographic microscope as an in put device to aid in the study of pore systems. Standard Petrographic thin sections are typically 30 micrometers thick and are usually illuminated by transmitted light. Experienced examiners have trained themselves to see information such as pore size, mineralogy, compaction, etc by disregarding artifacts produced by passing light through a section. This method is adequate for qualitative interpretation of data from thin sections. Rocks in thin section under a microscope display great complexity in pore sizes and shapes. Petrographic study provides measurement on rock texture. Texture deals with the size, shape and arrangement of the component minerals of a rock. It is essentially the micro geometry of the rock. Permeability of collected core plugs of lower Goru sandstones was measured. From this Petrographic study we have identified as the sandstone of Lower Goru constitute almost entirely of quartz. The grains range in size from very fine to medium, moderately well sorted to well sorted and rounded to sub rounded in shape. Particularly attention was paid to mineral content present in Lower Goru Sandstone. The mineral composition from these core plugs of Lower Goru Sandstone as identified contain about 70-80% Quartz with traces of feldspar, muscovite, biotite, Epidote and hornblende. Calcite was present as cementing material and it was about 15 -30% of the total rock. (author)

  13. The newly developed Toyota plug-in hybrid system

    Energy Technology Data Exchange (ETDEWEB)

    Takaoka, Toshifumi; Ichinose, Hiroki [Toyota Motor Corporation (Japan)

    2010-07-01

    Toyota has been introducing several hybrid vehicles (HV) as a countermeasure to the automobile's concerns, like CO2 reduction, energy security, and emission reduction in urban areas. A next step towards an even more effective solution for these concerns is a plug-in hybrid vehicle (PHV). This vehicle combines the advantages of electric vehicles (EV), which use clean electric energy, and HV, with it's high environmental potential and user- friendliness comparable to conventional vehicles, such as a long cruising range. This paper describes a newly developed plug-in hybrid system and its vehicle performance. This system uses a Li-ion battery with high energy density and has an affordable EV range without sacrificing cabin space. The vehicle achieves a CO2 emission of 59g/km and meets the most stringent emission regulations in the world. The new PHV is a forerunner of the large-scale mass production PHV two years later. PHVs have the potential to become popular as a realistic solution towards sustainable mobility by renewable electricity usage in the future. (orig.)

  14. Selecting Female Mice in Estrus and Checking Plugs.

    Science.gov (United States)

    Behringer, Richard; Gertsenstein, Marina; Nagy, Kristina Vintersten; Nagy, Andras

    2016-08-01

    The female mouse estrous cycle is divided into four phases: proestrus (development of ovarian follicles), estrus (ovulation), metestrus (formation of corpora lutea), and diestrus (beginning of follicle development for next ovulation and elimination of previous oocytes). The appearance of the epithelium of the external genitalia is used to identify the stage of the estrous cycle of a female mouse. This is usually easier to see in strains with either no or only light skin pigmentation. By examining the color, moistness, and degree of swelling of the vagina, females in estrus can readily be identified. To set up the matings, females are examined in the afternoon, and those in estrus are placed into the cages with males (one or two females in each cage with one male). Usually, 50% or more of the selected females will mate. The presence of a vaginal copulation plug next morning indicates that mating has occurred, but it does not mean that a pregnancy will result even if proven breeder fertile males were used. It is important to check vaginal plugs early in the morning because they fall out or are no longer detectable ~12 h after mating or sometimes earlier. © 2016 Cold Spring Harbor Laboratory Press.

  15. Geothermal Well Site Restoration and Plug and Abandonment of Wells

    Energy Technology Data Exchange (ETDEWEB)

    Rinehart, Ben N.

    1994-08-01

    A report is presented on the final phase of an energy research program conducted by the U.S. Department of Energy (DOE) involving two geothermal well sites in the State of Louisiana-the Gladys McCall site and the Willis Hulin site. The research program was intended to improve geothermal technology and to determine the efficacy of producing electricity commercially from geopressured resource sites. The final phase of the program consisted of plug and abandonment (P&A) of the wells and restoration of the well sites. Restoration involved (a) initial soil and water sampling and analysis; (b) removal and disposal of well pads, concrete, utility poles, and trash; (c) plugging of monitor and freshwater wells; and (d) site leveling and general cleanup. Restoration of the McCall site required removal of naturally occurring radioactive material (NORM), which was costly and time-consuming. Exhibits are included that provide copies of work permits and authorizations, P&A reports and procedures, daily workover and current conditions report, and cost and salvage reports. Site locations, grid maps, and photographs are provided.

  16. Development and application of microbial selective plugging processes

    Energy Technology Data Exchange (ETDEWEB)

    Jenneman, G.E. [Phillips Petroleum Co., Bartlesville, OK (United States); Gevertz, D.; Davey, M.E. [Agouron Institute, La Jolla, CA (United States)] [and others

    1995-12-31

    Phillips Petroleum Company recently completed a microbial selective plugging (MSP) pilot at the North Burbank Unit (NBU), Shidler, Oklahoma. Nutrients were selected for the pilot that could stimulate indigenous microflora in the reservoir brine to grow and produce exopolymer. It was found that soluble corn starch polymers (e.g., maltodextrins) stimulated the indigenous bacteria to produce exopolymer, whereas simple sugars (e.g., glucose and sucrose), as well as complex media (e.g., molasses and Nutrient Broth), did not. Injection of maltodextrin into rock cores in the presence of indigenous NBU bacteria resulted in stable permeability reductions (> 90%) across the entire length, while injection of glucose resulted only in face plugging. In addition, it was found that organic phosphate esters (OPE) served as a preferable source of phosphorus for the indigenous bacteria, since orthophosphates and condensed phosphates precipitated in NBU brine at reservoir temperature (45{degrees}C). Injection of maltodextrin and ethyl acid phosphate into a producing well stimulated an increase in maltodextrin utilizing bacteria (MUB) in the back-flowed, produced fluid. Additional screens of indigenous and nonindigenous bacteria yielded several nonindigenous isolates that could synthesize polymer when growing in brine containing 6% NaCl at 45{degrees}C.

  17. Nuclear analysis of the ITER Cryopump Ports

    International Nuclear Information System (INIS)

    Moro, Fabio; Villari, Rosaria; Flammini, Davide; Antipenkov, Alexander; Dremel, Matthias; Levesy, Bruno; Loughlin, Michael; Juarez, Rafael; Perez, Lucia; Petrizzi, Luigino

    2015-01-01

    Highlights: • Evaluation the shielding effectiveness of the TCPHs by means of 3-D neutrons and gamma maps. • Assessment of the nuclear heating induced by neutron and photons on the TCP and TCPHs. • Calculation of the dose rate at 12 days after shutdown in the maintenance area of the Lower Ports with the Advanced D1S method, in order to verify the design target (100 μSv/h). • Potential improvements of the shielding configuration aimed at the reduction of the dose level in the Port Cell have been proposed and discussed. - Abstract: The ITER machine will be equipped with 6 torus Cryopumps (TCP) that are positioned in their housings (TCPH) and integrated into the cryostat walls at B1 level in the port cells. A comprehensive nuclear analysis of the Cryopump Ports #4 and #12 has been carried out by means of the MCNP-5 Monte Carlo code in a full 3-D geometry, providing guidelines for the design of the embedded components. Radiation transport calculations have been performed in order to determine the radiation field inside the Lower Ports, up the Port Cell: 3-D neutrons and gamma maps have been provided in order to evaluate the shielding effectiveness of the TCPHs. Nuclear heating induced by neutron and photons have been estimated on the TCP and TCPH to assess the nuclear loads during plasma operations. The shutdown dose rate in the maintenance area of the Lower Ports has been assessed with the Advanced D1S method to verify the design limits.

  18. Nuclear analysis of the ITER Cryopump Ports

    Energy Technology Data Exchange (ETDEWEB)

    Moro, Fabio, E-mail: fabio.moro@enea.it [ENEA, Fusion Technical Unit, Nuclear Technologies Laboratory, Via Enrico Fermi 45, 00044 Frascati, Rome (Italy); Villari, Rosaria; Flammini, Davide [ENEA, Fusion Technical Unit, Nuclear Technologies Laboratory, Via Enrico Fermi 45, 00044 Frascati, Rome (Italy); Antipenkov, Alexander; Dremel, Matthias; Levesy, Bruno; Loughlin, Michael [ITER Organization, Route de Vinon sur Verdon, 13115 Saint Paul-lez-Durance (France); Juarez, Rafael; Perez, Lucia [UNED, Energetic Engineering Department, C/Juan del Rosal 12, Madrid (Spain); Petrizzi, Luigino [European Commission, DG Research & Innovation G5, CDMA 00/030, B-1049 Brussels (Belgium)

    2015-10-15

    Highlights: • Evaluation the shielding effectiveness of the TCPHs by means of 3-D neutrons and gamma maps. • Assessment of the nuclear heating induced by neutron and photons on the TCP and TCPHs. • Calculation of the dose rate at 12 days after shutdown in the maintenance area of the Lower Ports with the Advanced D1S method, in order to verify the design target (100 μSv/h). • Potential improvements of the shielding configuration aimed at the reduction of the dose level in the Port Cell have been proposed and discussed. - Abstract: The ITER machine will be equipped with 6 torus Cryopumps (TCP) that are positioned in their housings (TCPH) and integrated into the cryostat walls at B1 level in the port cells. A comprehensive nuclear analysis of the Cryopump Ports #4 and #12 has been carried out by means of the MCNP-5 Monte Carlo code in a full 3-D geometry, providing guidelines for the design of the embedded components. Radiation transport calculations have been performed in order to determine the radiation field inside the Lower Ports, up the Port Cell: 3-D neutrons and gamma maps have been provided in order to evaluate the shielding effectiveness of the TCPHs. Nuclear heating induced by neutron and photons have been estimated on the TCP and TCPH to assess the nuclear loads during plasma operations. The shutdown dose rate in the maintenance area of the Lower Ports has been assessed with the Advanced D1S method to verify the design limits.

  19. 78 FR 24069 - Safety Zone; 12th Annual Saltwater Classic; Port Canaveral Harbor; Port Canaveral, FL

    Science.gov (United States)

    2013-04-24

    ... under Executive Order 13045, Protection of Children from Environmental Health Risks and Safety Risks. This rule is not an economically significant rule and does not create an environmental risk to health...-AA00 Safety Zone; 12th Annual Saltwater Classic; Port Canaveral Harbor; Port Canaveral, FL AGENCY...

  20. Single port laparoscopic ileocaecal resection for Crohn's disease: a multicentre comparison with multi-port laparoscopy

    NARCIS (Netherlands)

    Carvello, M.; de Groof, E. J.; de Buck van Overstraeten, A.; Sacchi, M.; Wolthuis, A. M.; Buskens, C. J.; D'Hoore, A.; Bemelman, W. A.; Spinelli, A.

    2018-01-01

    AimSingle port (SP) ileocaecal resection (ICR) is an established technique but there are no large studies comparing SP and multi-port (MP) laparoscopic surgery in Crohn's disease (CD). The aim of this study was to compare postoperative pain scores and analgesia requirements after SP and MP

  1. Molecular Diagnostics

    OpenAIRE

    Choe, Hyonmin; Deirmengian, Carl A.; Hickok, Noreen J.; Morrison, Tiffany N.; Tuan, Rocky S.

    2015-01-01

    Orthopaedic infections are complex conditions that require immediate diagnosis and accurate identification of the causative organisms to facilitate appropriate management. Conventional methodologies for diagnosis of these infections sometimes lack accuracy or sufficient rapidity. Current molecular diagnostics are an emerging area of bench-to-bedside research in orthopaedic infections. Examples of promising molecular diagnostics include measurement of a specific biomarker in the synovial fluid...

  2. Laser ignition - Spark plug development and application in reciprocating engines

    Science.gov (United States)

    Pavel, Nicolaie; Bärwinkel, Mark; Heinz, Peter; Brüggemann, Dieter; Dearden, Geoff; Croitoru, Gabriela; Grigore, Oana Valeria

    2018-03-01

    Combustion is one of the most dominant energy conversion processes used in all areas of human life, but global concerns over exhaust gas pollution and greenhouse gas emission have stimulated further development of the process. Lean combustion and exhaust gas recirculation are approaches to improve the efficiency and to reduce pollutant emissions; however, such measures impede reliable ignition when applied to conventional ignition systems. Therefore, alternative ignition systems are a focus of scientific research. Amongst others, laser induced ignition seems an attractive method to improve the combustion process. In comparison with conventional ignition by electric spark plugs, laser ignition offers a number of potential benefits. Those most often discussed are: no quenching of the combustion flame kernel; the ability to deliver (laser) energy to any location of interest in the combustion chamber; the possibility of delivering the beam simultaneously to different positions, and the temporal control of ignition. If these advantages can be exploited in practice, the engine efficiency may be improved and reliable operation at lean air-fuel mixtures can be achieved, making feasible savings in fuel consumption and reduction in emission of exhaust gasses. Therefore, laser ignition can enable important new approaches to address global concerns about the environmental impact of continued use of reciprocating engines in vehicles and power plants, with the aim of diminishing pollutant levels in the atmosphere. The technology can also support increased use of electrification in powered transport, through its application to ignition of hybrid (electric-gas) engines, and the efficient combustion of advanced fuels. In this work, we review the progress made over the last years in laser ignition research, in particular that aimed towards realizing laser sources (or laser spark plugs) with dimensions and properties suitable for operating directly on an engine. The main envisaged

  3. Evaluation of the Necessity of Port Fixation in Central Venous Port Implantation

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Sang Su; Kim, Hyung Pil [Inje University Pusan Paik Hospital, Busan (Korea, Republic of); Bae, Jae Ik; Won, Je Hwan [Ajou University School of Medicine, Suwon (Korea, Republic of)

    2010-06-15

    The technical success and complications were especially focused on and evaluated the need for fixation of a port under fluoroscopic guidance placement of the totally implantable central venous access ports for long term central venous access. Two hundred eighty nine consecutive patients (170 men, 119 women, mean age: 52-year-old) who underwent venous port implantation for the administration of chemotherapy were followed over a 1-month period. The procedures were performed in the angiographic suite by an interventional radiologist and all access was through the right jugular vein, except for the patients who had undergone a right mastectomy. The procedures were performed in the following order: 1) venous puncture, 2) making a pocket, 3) catheter tunneling, 4) port insertion, 5) catheter sizing, and 6) insertion. A port which was connected to the tunneled catheter was inserted into the minimally sized subcutaneous pocket with the aid of a small retractor. A follow-up was performed with medical records and chest radiographs. The follow-up period for evaluating the venous port ranged from 59 to 329 days (mean: 175 days) The procedures performed to gain right jugular vein access were successful without difficulty in all cases. The 18 patients that underwent procedures to gain left jugular vein access encountered some difficulty upon insertion of a catheter into the SVC due to encountering the tortuous left brachiocephalic vein. No complications occurred during and immediately after the procedure. In one case the port chamber rotated within the subcutaneous pocket; however, no catheter migration or malfunction occurred. If port insertion was followed by catheter insertion, the port chamber can be tightly implanted in the minimally sized pocket. This would avoid the need for fixation of the catheter to the port chamber leading into the pocket

  4. Dynamism Patterns of Western Mediterranean Cruise Ports and the Coopetition Relationships Between Major Cruise Ports

    Directory of Open Access Journals (Sweden)

    Esteve-Perez Jeronimo

    2018-03-01

    Full Text Available The Mediterranean Sea has seen an increase of ports hosting cruise ships during the first fifteen years of the 21st century. The increase in cruise ship presence in Mediterranean ports is associated with the dynamism of cruise traffic in recent years, with an average annual growth of 7.45% for cruise passengers worldwide during the period of 1990-2015. Cruise traffic is a maritime business that is primarily composed of two elements, maritime affairs and tourism. This article focuses on the maritime component. With the growth of the cruise industry, cruise lines have been forced to seek new ports to meet demand in an attempt to create differentiated products based on the ports that compose the itinerary. The itinerary system of cruise traffic makes the cruise ports depend on one another to design an itinerary. This feature results in both complex geographic relationships in the design of a cruise itinerary and complex competitive/cooperative relationships between ports. The aim of this article is to present the hierarchic picture of a sample of 29 cruise ports in the Western Mediterranean region during the period of 2000-2015. To achieve this goal, a port size classification is proposed and a shift-share analysis at the inter- and intra-group size level is applied. Moreover, concentration measures are used to determine the changes in the levels of market concentration. Furthermore, a dynamic model is proposed to determine the competitive or cooperative relationships between cruise ports. The proposed model is applied to the largest ports with data from the 2001-2015 period.

  5. Simulation model for port shunting yards

    Science.gov (United States)

    Rusca, A.; Popa, M.; Rosca, E.; Rosca, M.; Dragu, V.; Rusca, F.

    2016-08-01

    Sea ports are important nodes in the supply chain, joining two high capacity transport modes: rail and maritime transport. The huge cargo flows transiting port requires high capacity construction and installation such as berths, large capacity cranes, respectively shunting yards. However, the port shunting yards specificity raises several problems such as: limited access since these are terminus stations for rail network, the in-output of large transit flows of cargo relatively to the scarcity of the departure/arrival of a ship, as well as limited land availability for implementing solutions to serve these flows. It is necessary to identify technological solutions that lead to an answer to these problems. The paper proposed a simulation model developed with ARENA computer simulation software suitable for shunting yards which serve sea ports with access to the rail network. Are investigates the principal aspects of shunting yards and adequate measures to increase their transit capacity. The operation capacity for shunting yards sub-system is assessed taking in consideration the required operating standards and the measure of performance (e.g. waiting time for freight wagons, number of railway line in station, storage area, etc.) of the railway station are computed. The conclusion and results, drawn from simulation, help transports and logistics specialists to test the proposals for improving the port management.

  6. Specialization and Flexibility in Port Cargo Handling

    Directory of Open Access Journals (Sweden)

    Hakkı KİŞİ

    2016-11-01

    Full Text Available Cargo handling appears to be the fundamental function of ports. In this context, the question of type of equipment and capacity rate need to be tackled with respect to cargo handling principles. The purpose of this study is to discuss the types of equipment to be used in ports, relating the matter to costs and capacity. The question is studied with a basic economic theoretical approach. Various conditions like port location, size, resources, cargo traffic, ships, etc. are given parameters to dictate the type and specification of the cargo handling equipment. Besides, a simple approach in the context of cost capacity relation can be useful in deciding whether to use specialized or flexible equipment. Port equipment is sometimes expected to be flexible to handle various types of cargo as many as possible and sometimes to be specialized to handle one specific type of cargo. The cases that might be suitable for those alternatives are discussed from an economic point of view in this article. Consequently, effectiveness and efficiency criteria play important roles in determining the handling equipment in ports.

  7. Pollution prevention at ports: clearing the air

    International Nuclear Information System (INIS)

    Bailey, Diane; Solomon, Gina

    2004-01-01

    Seaports are major hubs of economic activity and of environmental pollution in coastal urban areas. Due to increasing global trade, transport of goods through ports has been steadily increasing and will likely continue to increase in the future. Evaluating air pollution impacts of ports requires consideration of numerous sources, including marine vessels, trucks, locomotives, and off-road equipment used for moving cargo. The air quality impacts of ports are significant, with particularly large emissions of diesel exhaust, particulate matter, and nitrogen oxides. The health effects of these air pollutants to residents of local communities include asthma, other respiratory diseases, cardiovascular disease, lung cancer, and premature mortality. In children, there are links with asthma, bronchitis, missed school days, and emergency room visits. The significance of these environmental health impacts requires aggressive efforts to mitigate the problem. Approaches to mitigation encompass a range of possibilities from currently available, low-cost approaches, to more significant investments for cleaner air. Examples of the former include restrictions on truck idling and the use of low-sulfur diesel fuel; the latter includes shore-side power for docked ships, and alternative fuels. A precautionary approach to port-related air pollution would encourage local production of goods in order to reduce marine traffic, greener design for new terminals, and state-of-the art approaches to emissions-control that have been successfully demonstrated at ports throughout the world

  8. High-Surety Telemedicine in a Distributed, 'Plug-and-Play' Environment

    International Nuclear Information System (INIS)

    Craft, Richard L.; Funkhouser, Donald R.; Gallagher, Linda K.; Garcia, Rudy J.; Parks, Raymond C.; Warren, Steve

    1999-01-01

    Commercial telemedicine systems are increasingly functional, incorporating video-conferencing capabilities, diagnostic peripherals, medication reminders, and patient education services. However, these systems (1) rarely utilize information architectures which allow them to be easily integrated with existing health information networks and (2) do not always protect patient confidentiality with adequate security mechanisms. Using object-oriented methods and software wrappers, we illustrate the transformation of an existing stand-alone telemedicine system into 'plug-and-play' components that function in a distributed medical information environment. We show, through the use of open standards and published component interfaces, that commercial telemedicine offerings which were once incompatible with electronic patient record systems can now share relevant data with clinical information repositories while at the same time hiding the proprietary implementations of the respective systems. Additionally, we illustrate how leading-edge technology can secure this distributed telemedicine environment, maintaining patient confidentiality and the integrity of the associated electronic medical data. Information surety technology also encourages the development of telemedicine systems that have both read and write access to electronic medical records containing patient-identifiable information. The win-win approach to telemedicine information system development preserves investments in legacy software and hardware while promoting security and interoperability in a distributed environment

  9. High-Surety Telemedicine in a Distributed, 'Plug-andPlan' Environment

    Energy Technology Data Exchange (ETDEWEB)

    Craft, Richard L.; Funkhouser, Donald R.; Gallagher, Linda K.; Garcia, Rudy J.; Parks, Raymond C.; Warren, Steve

    1999-05-17

    Commercial telemedicine systems are increasingly functional, incorporating video-conferencing capabilities, diagnostic peripherals, medication reminders, and patient education services. However, these systems (1) rarely utilize information architectures which allow them to be easily integrated with existing health information networks and (2) do not always protect patient confidentiality with adequate security mechanisms. Using object-oriented methods and software wrappers, we illustrate the transformation of an existing stand-alone telemedicine system into `plug-and-play' components that function in a distributed medical information environment. We show, through the use of open standards and published component interfaces, that commercial telemedicine offerings which were once incompatible with electronic patient record systems can now share relevant data with clinical information repositories while at the same time hiding the proprietary implementations of the respective systems. Additionally, we illustrate how leading-edge technology can secure this distributed telemedicine environment, maintaining patient confidentiality and the integrity of the associated electronic medical data. Information surety technology also encourages the development of telemedicine systems that have both read and write access to electronic medical records containing patient-identifiable information. The win-win approach to telemedicine information system development preserves investments in legacy software and hardware while promoting security and interoperability in a distributed environment.

  10. Fewer-than-four ports versus four ports for laparoscopic cholecystectomy.

    Science.gov (United States)

    Gurusamy, Kurinchi Selvan; Vaughan, Jessica; Rossi, Michele; Davidson, Brian R

    2014-02-20

    Traditionally, laparoscopic cholecystectomy is performed using two 10-mm ports and two 5-mm ports. Recently, a reduction in the number of ports has been suggested as a modification of the standard technique with a view to decreasing pain and improving cosmesis. The safety and effectiveness of using fewer-than-four ports has not yet been established. To assess the benefits (such as improvement in cosmesis and earlier return to activity) and harms (such as increased complications) of using fewer-than-four ports (fewer-than-four-ports laparoscopic cholecystectomy) versus four ports in people undergoing laparoscopic cholecystectomy for any reason (symptomatic gallstones, acalculous cholecystitis, gallbladder polyp, or any other condition). We searched the Cochrane Central Register of Controlled Trials (CENTRAL; Issue 8, 2013), MEDLINE, EMBASE, Science Citation Index Expanded, and the World Health Organization International Clinical Trials Registry Platform portal to September 2013. We included all randomised clinical trials comparing fewer-than-four ports versus four ports, that is, with standard laparoscopic cholecystectomy that is performed with two ports of at least 10-mm incision and two ports of at least 5-mm incision. Two review authors independently identified the trials and extracted the data. We analysed the data using both the fixed-effect and the random-effects models. For each outcome, we calculated the risk ratio (RR) or mean difference (MD) with 95% confidence intervals (CI) based on intention-to-treat analysis, whenever possible. We found nine trials with 855 participants that randomised participants to fewer-than-four-ports laparoscopic cholecystectomy (n = 427) versus four-port laparoscopic cholecystectomy (n = 428). Most trials included low anaesthetic risk participants undergoing elective laparoscopic cholecystectomy. Seven of the nine trials used a single port laparoscopic cholecystectomy and the remaining two trials used three-port laparoscopic

  11. Intra-arterial port implantation for intra-arterial chemotherapy : comparison between PIPS(Percutaneously Implantable Port System) and port system

    International Nuclear Information System (INIS)

    Yoon, Sang Jin; Shim, Hyung Jin; Jung, Hun Young; Choi, Yong Ho; Kim, Yang Soo; Song, In Sup; Kwak, Byung Kook

    1999-01-01

    To compare the techniques and complications of intra-arterial port implantation for intra-arterial chemotherapy between PIPS and the port system. For intra-arterial port implantation, 27 cases in 27 patients were retrospectively evaluated using PIPS(PIPS-200, William Cook Europe, Denmark) while for 21 cases in 19 patients a pediatric venous port system(Port-A-Cath, 5.8F, SIMS Deltec, U. S. A.) was used. All intra-arterial port implantation was performed percuteneously in an angiographic ward. Hepatocellular carcinoma was diagnosed in 18 patients and hepatic metastasis in 16. Peripheral cholangiocarcinoma, and pancreatic gastric, ovarian, renal cell and colon carcinoma were included. We compared the techniques and complications between PIPS and the port system. The follow up period ranged from 23 to 494(mean, 163) days in PIPS and from 12 to 431(mean, 150) days in the port system. In all cases, intra-arterial port implantations were technically successful. Port catheter tips were located in the common hepatic artery(n=8), proper hepatic artery(n=7), right hepatic artery(n=5), gastroduodenal artery(n=2), left hepatic artery(n=1), pancreaticoduodenal artery(n=1), inferior mesenteric artery(n=1), lumbar artery(n=1), and renal artery(n=1) in PIPS, and in the proper hepatic artery(n=6), gastroduodenal artery(n=6), common hepatic artery(n=3), right hepatic artery(n=4), inferior mesenteric artery(n=1), and internal iliac artery(n=1) in the port system. Port chambers were buried in infrainguinal subcutaneous tissue. Using PIPS, complications developed in seven cases(25.9%) and of these, four (57.1%) were catheter or chamber related. In the port system, catheter or chamber related complications developed in four cases(19.0%). Because PIPS and the port system have relative merits and demetrits, successful intra-arterial port implantation is possible if equipment is properly selected

  12. PERFORMANCE ASSESSMENT IN OPERATING DRY PORTS

    Directory of Open Access Journals (Sweden)

    Ciortescu Cezar-Gabriel

    2010-12-01

    Full Text Available In this paper, an approach for recognizing and defining correct and operable performance will be presented with the purpose of evaluating the effectiveness and efficiency of processes in dry ports (inland intermodal hubs. The challenge in evaluating the possible improvements of the underlying processes lies in the special nature and the complex structure of dry ports. It is important to consider that all the processes are highly interconnected and that changes in parameters in one process also have an impact on parameters in other processes. Furthermore, the performance of dry ports, seen as the backbone of the system, has a significant impact on the overall performance of the whole transportation network.

  13. Development Possibilities of the Port of Koper

    Directory of Open Access Journals (Sweden)

    Igor Trupac

    2002-03-01

    Full Text Available The extent to which Slovenia will exploit its good geographictransport position, whether it will be merely a transportcorridor or assume an additional quality (e.g. a distributioncentre or a logistic centre will depend on a cluster of circumstances.The importance will also be laid on how Slovenia willpresent itself and what it will offer to Europe and the rest of theworld. One of its best assets is the Port of Koper (favourable position,good condition, capacities in the frame of the whole logisticsystem.A larger volume of transport and consequently be/fer exploitationof the Port of Koper will in the future depend on increasedtransit. However, to acquire new cargo, the mere installationand modernisation of port infrastructure and rise in thequality of services may not be sufficient: it will also require goodconnections to the hinterland.

  14. Smartphone audio port data collection cookbook

    Directory of Open Access Journals (Sweden)

    Kyle Forinash

    2018-06-01

    Full Text Available The audio port of a smartphone is designed to send and receive audio but can be harnessed for portable, economical, and accurate data collection from a variety of sources. While smartphones have internal sensors to measure a number of physical phenomena such as acceleration, magnetism and illumination levels, measurement of other phenomena such as voltage, external temperature, or accurate timing of moving objects are excluded. The audio port cannot be only employed to sense external phenomena. It has the additional advantage of timing precision; because audio is recorded or played at a controlled rate separated from other smartphone activities, timings based on audio can be highly accurate. The following outlines unpublished details of the audio port technical elements for data collection, a general data collection recipe and an example timing application for Android devices.

  15. Temporary abandonment cement plug on the liner top; Tampao de abandono temporario na boca do liner

    Energy Technology Data Exchange (ETDEWEB)

    Hiss Filho, Paulo Henrique; Costa Junior, Pedro Americo da; Viana, Jose Luis Rodrigues [PETROBRAS, Rio de Janeiro, RJ (Brazil). Distrito de Pefuracao do Sudeste. Div. de Tecnicas de Perfuracao

    1994-07-01

    In many instances wells are temporary abandoned just after cementing liner to be completed later or to have the BOP removed to change rams. In these cases, an additional volume of slurry is designed in order to bring the top of cement plug over the liner top, thus saving the time required for all full plugging operation. (author)

  16. Self-similar drag reduction in plug-flow of suspensions of macroscopic fibers

    NARCIS (Netherlands)

    Gillissen, J.J.J.; Hoving, J.P.

    2012-01-01

    Pipe flow experiments show that turbulent drag reduction in plug-flow of concentrated suspensions of macroscopic fibers is a self-similar function of the wall shear stress over the fiber network yield stress. We model the experimental observations, by assuming a central fiber network plug, whose

  17. Bilateral transrenal ureteral occlusion by means of n-butyl cyanoacrylate and AMPLATZER vascular plug

    Directory of Open Access Journals (Sweden)

    Rosario F Grasso

    2014-01-01

    Full Text Available AMPLATZER vascular plug is a widely used embolic agent. In the present paper, we present a case of an 86-year-old female patient who underwent bilateral ureteral occlusion by means of AMPLATZER vascular plug II coupled to n-butyl cyanoacrylate (NBCA because of recurring pyelonephritis following cystectomy with subsequent bilateral ureterosigmoidostomy (sec. Mainz type II.

  18. 78 FR 68714 - Medical Devices; Ophthalmic Devices; Classification of the Scleral Plug

    Science.gov (United States)

    2013-11-15

    ... amendments), as ``preamendments devices.'' FDA classifies these devices after the Agency takes the following.... FDA-2012-N-1238] Medical Devices; Ophthalmic Devices; Classification of the Scleral Plug AGENCY: Food... scleral plugs in order to provide a reasonable assurance of safety and effectiveness of the device. The...

  19. Cement technology for borehole plugging: an interim report on permeability measurements of cementitious solids

    International Nuclear Information System (INIS)

    McDaniel, E.W.

    1980-01-01

    The permeability of borehole plug solids and plug-wall rock junctions is a property of major interest in the Borehole Plugging Program. This report describes the equipment and techniques used to determine the permeabilities of possible borehole plugging materials and presents results from tests on various cementitious solids and plug-rock combinations. The cementitious solids were made from mixtures of cement, sand, salt, fly ash, and water. Three different types of cement and four different fly ashes were used. Permeabilities ranged from a high value of 3 x 10 -4 darcy for a neat cement paste to a low of 5 x 10 -8 darcy for a saltcrete containing 30 wt % sodium chloride. Miniature boreholes were made in the following four different types of rock: Westerly granite, Dresser basalt, Sioux quartzite, and St. Cloud granodiorite. These small holes were plugged with a mix consisting of 23 wt % Type I Portland cement, 20 wt % bituminous fy ash, 43.2 wt % sand, and 13.8 wt % water. After curing for 91 days at ambient temperature, the permeability of the plug-wall rock junctions ranged from 3 x 10 -5 to -8 darcy. Three of the four miniature plugged boreholes exhibited permeabilities of < 10 microdarcys

  20. Plug and Play Process Control Applied to a District Heating System

    DEFF Research Database (Denmark)

    Knudsen, Torben; Trangbæk, Klaus; Kallesøe, Carsten Skovmose

    2008-01-01

    The general ideas within plug and play process control (PTC) are to initialize and reconfigure control systems just by plug and play. In this paper these ideas are applied to a district heating pressure control problem. First of all this serves as a concrete example of PTC, secondly some of the f...