WorldWideScience

Sample records for devices undergoing high

  1. Beyond the five-year horizon: long-term outcome of high-risk and inoperable patients undergoing TAVR with first-generation devices.

    Science.gov (United States)

    Deutsch, Marcus-André; Erlebach, Magdalena; Burri, Melchior; Hapfelmeier, Alexander; Witt, Olivia Ganga; Ziegelmueller, Johannes Amadeus; Wottke, Michael; Ruge, Hendrik; Krane, Markus; Piazza, Nicolo; Bleiziffer, Sabine; Lange, Rüdiger

    2018-05-20

    We sought to determine the long-term outcome of high-risk patients who underwent transcatheter aortic valve replacement (TAVR) with first-generation devices with a focus on the identification of predictors for mortality and valve durability. Consecutive patients in our prospective single-centre registry undergoing TAVR with first-generation devices (n=214 CoreValve; n=86 SAPIEN) between 06/2007 and 07/2009 were retrospectively analysed (n=300, mean age 81.43±6.55 years, mean STS score 6.5±4.5%). Kaplan-Meier estimates of survival and the Cox proportional hazards model were used to identify independent predictors of all-cause-mortality. At 1, 5, and 7 years, estimated survival rates were 76.0%, 40.2%, and 23.2%, respectively. Age-adjusted baseline predictors of mortality included atrial fibrillation, impaired kidney function, peripheral artery disease, and mitral regurgitation (≥moderate). Baseline risk-adjusted procedure-related predictors for all-cause mortality included acute kidney injury, neurological events, major vascular complications, and major/life-threatening bleeding. At both five and six years, 78.2% of surviving patients were in NYHA Class I or II. PVL was ≤mild in the majority of patients at discharge and throughout follow-up. At seven years, the overall crude cumulative incidence of structural valve deterioration according to the 2017 EAPCI/ESC/EACTS definition was 14.9% (CoreValve 11.8% vs. SAPIEN 22.6%; p=0.01). Seven years after TAVR, 23.2% of high-risk patients were still alive. Independent predictors of all-cause mortality included both patient- and procedure-related factors. With a cumulative incidence of 14.9% at seven years, there is some suggestion that SVD post TAVR may become increasingly relevant during longer-term follow-up.

  2. Protection device for a thermonuclear device

    International Nuclear Information System (INIS)

    Kawashima, Shuichi.

    1986-01-01

    Purpose: To exactly detect the void coefficients of coolants even under high magnetic fields thereby detect the overheat of a thermonuclear device at an early stage. Constitution: The protecting device of this invention comprises a laser beam generation device, a laser beam detection device and an accident detection device. The laser generation device always generates laser beams, which are permeated through coolants and detected by the laser beam detection device, the optical amount of which is transmitted to the accident detection device. The accident detection device judges the excess or insufficiency of the detected optical amount with respect to the optical amount of the laser beams under the stationary state as a reference and issues an accident signal. Since only the optical cables that do not undergo the effect of the magnetic fields are exposed to high magnetic fields in the protection device of this invention, a high reliability can be maintained. (Kamimura, M.)

  3. Cardiac implantable electronic device and associated risk of infective endocarditis in patients undergoing aortic valve replacement

    DEFF Research Database (Denmark)

    Østergaard, Lauge; Valeur, Nana; Bundgaard, Henning

    2017-01-01

    Aims: Patients undergoing aortic valve replacement (AVR) are at increased risk of infective endocarditis (IE) as are patients with a cardiac implantable electronic device (CIED). However, few data exist on the IE risk after AVR surgery in patients with a CIED. Methods and results: Using the Danish...

  4. High heat flux device of thermonuclear device

    International Nuclear Information System (INIS)

    Tachikawa, Nobuo.

    1994-01-01

    The present invention provides an equipments for high heat flux device (divertor) of a thermonuclear device, which absorbs thermal deformation during operation, has a high installation accuracy, and sufficiently withstands for thermal stresses. Namely, a heat sink member is joined to a structural base. Armour tiles are joined on the heat sink member. Cooling pipes are disposed between the heat sink member and the armour tiles. With such a constitution, the heat sink member using a highly heat conductive material having ductility, such as oxygen free copper, the cooling pipes using a material having excellent high temperature resistance and excellent elongation, such as aluminum-dispersed reinforced copper, and the armour tiles are completely joined on the structural base. Therefore, when thermal deformation tends to cause in the high heat flux device such as a divertor, cooling pipes cause no plastic deformation because of their high temperature resistance, but the heat sink member such as a oxygen free copper causes plastic deformation to absorb thermal deformation. As a result, the high heat flux device such as a divertor causes no deformation. (I.S.)

  5. Perioperative management of calves undergoing implantation of a left ventricular assist device.

    Science.gov (United States)

    Wilson, D V; Kantrowitz, A; Pacholewicz, J; Salat, O; Paules, B R; Zhou, Y; Dawe, E J

    2000-01-01

    To describe perioperative management of calves that underwent left lateral thoracotomy, aortic cross-clamping, partial left heart bypass and implantation of a left ventricular assist device. A total of 43 healthy castrated male calves, weighing 121 +/- 24 kg. Diazepam (mean +/- SD, 0.26 +/- 0.07 mg/kg), ketamine (5.9 +/- 2.17 mg/kg) and isoflurane were used in the anesthetic management of calves undergoing implantation of a left ventricular assist device in the descending thoracic aorta. Other adjunctive agents administered were fentanyl (11 +/- 5.4 microg/kg), lidocaine (4.9 +/- 3.19 mg/kg), bupivacaine (0.75%) and butorphanol (0.49 +/- 0.13 mg/kg). None of the calves regurgitated at induction or during intubation. A tube was used to drain the rumen and prevent bloat during the procedure. Partial left heart bypass was used to perfuse the caudal half of the body during the period of aortic cross clamp and device implantation. Initial mean systemic blood pressure was 96 +/- 25 mm Hg, and pressures measured in the auricular artery increased during aortic cross-clamping and bypass. Vasoconstrictor therapy was required to treat caudal arterial hypotension during the procedure in 9 calves. Mean systemic arterial pressures returned to baseline values by the end of the anesthetic period. Initial mean pulmonary arterial pressures (PAP) were 22 +/- 3 mm Hg. A significant but transient increase in pulmonary arterial pressure occurred after both heparin and protamine administration. The described anesthetic protocol was effective for thoracotomy and implantation of an intra-aortic left ventricular assist device in normal calves. Partial left ventricular bypass was a useful adjunct during the period of aortic cross clamp. The doses of heparin and protamine administered were effective. Responsibility to monitor oxygenation of the cranial half of the animal continues during the bypass period as hypoxemia due to pulmonary dysfunction will not be detected by the perfusionist.

  6. Multidisciplinary perioperative protocol in patients undergoing acute high-risk abdominal surgery

    DEFF Research Database (Denmark)

    Tengberg, L. T.; Bay-Nielsen, M.; Bisgaard, T.

    2017-01-01

    Background: Acute high-risk abdominal (AHA) surgery carries a very high risk of morbidity and mortality and represents a massive healthcare burden. The aim of the present study was to evaluate the effect of a standardized multidisciplinary perioperative protocol in patients undergoing AHA surgery...... = 0·004). Conclusion: The introduction of a multidisciplinary perioperative protocol was associated with a significant reduction in postoperative mortality in patients undergoing AHA surgery. NCT01899885 (http://www.clinicaltrials.gov)....

  7. A protocol for patients with cardiovascular implantable devices undergoing magnetic resonance imaging (MRI): should defibrillation threshold testing be performed post-(MRI).

    Science.gov (United States)

    Burke, Peter Thomas; Ghanbari, Hamid; Alexander, Patrick B; Shaw, Michael K; Daccarett, Marcos; Machado, Christian

    2010-06-01

    Magnetic resonance imaging (MRI) in patients with Cardiovascular Implantable Electronic Devices (CIED) has not been approved by the Food and Drug Administration. Recent data suggests MRI as a relative rather than absolute contraindication in CIED patients. Recently, the American Heart Association has recommended defibrillation threshold testing (DFTT) in implantable cardioverter defibrillator (ICD) patients undergoing MRI. We evaluated the feasibility and safety of a protocol for MRI in CIED patients, incorporating the new recommendations on DFTT. Consecutive patients with CIED undergoing MRI were included. The protocol consisted of continuous monitoring during imaging, device interrogation pre- and post-MRI, reprogramming of the pacemaker to an asynchronous mode in pacemaker-dependent (PMD) patients and a non-tracking/sensing mode for non-PMD patients. All tachyarrhythmia therapies were disabled. Devices were interrogated for lead impedance, battery life, pacing, and sensing thresholds. All patients with ICD underwent DFTT/defibrillator safety margin testing (DSMT) post-MRI. A total of 92 MRI's at 1.5 Tesla were performed in 38 patients. A total of 13 PMD patients, ten ICD patients, four cardiac resynchronization therapy with defibrillator (CRT-D) patients, and 11 non-PMD patients were scanned from four major manufacturers. No device circuitry damage, programming alterations, inappropriate shocks, failure to pace, or changes in sensing, pacing, or defibrillator thresholds were found on single or multiple MRI sessions. Our protocol for MRI in CIED patients appears safe, feasible, and reproducible. This is irrespective of the type of CIED, pacemaker dependancy or multiple 24-h scanning sessions. Our protocol addresses early detection of potential complications and establishes a response system for potential device-related complications. Our observation suggests that routine DFTT/DSMT post-MRI may not be necessary.

  8. First-in-man use of a novel embolic protection device for patients undergoing transcatheter aortic valve implantation.

    Science.gov (United States)

    Naber, Christoph K; Ghanem, Alexander; Abizaid, Alexander A; Wolf, Alexander; Sinning, Jan-Malte; Werner, Nikos; Nickenig, Georg; Schmitz, Thomas; Grube, Eberhard

    2012-05-15

    We describe the first-in-human experience with a novel cerebral embolic protection device used during transcatheter aortic valve implantation (TAVI). One current challenge of TAVI is the reduction of procedural stroke. Procedural mobilisation of debris is a known source of cerebral embolisation. Mechanical protection by transient filtration of cerebral blood flow might reduce the embolic burden during TAVI. We aimed to evaluate the feasibility and safety of the Claret CE Pro™ cerebral protection device in patients undergoing TAVI. Patients scheduled for TAVI were prospectively enrolled at three centres. The Claret CE Pro™ (Claret Medical, Inc. Santa Rosa, CA, USA) cerebral protection device was placed via the right radial/brachial artery prior to TAVI and was removed after the procedure. The primary endpoint was technical success rate. Secondary endpoints encompassed procedural and 30-day stroke rates, as well as device-related complications. Deployment of the Claret CE Pro™ cerebral protection device was intended for use in 40 patients, 35 devices were implanted into the aortic arch. Technical success rate with delivery of the proximal and distal filter was 60% for the first generation device and 87% for the second-generation device. Delivery times for the first-generation device were 12.4±12.1 minutes and 4.4 ± 2.5 minutes for the second-generation device (pto the Claret CE Pro System was 19.6 ± 3.8 ml. Captured debris was documented in at least 19 of 35 implanted devices (54.3%). No procedural transient ischaemic attacks, minor strokes or major strokes occurred. Thirty-day follow-up showed one minor stroke occurring 30 days after the procedure, and two major strokes both occurring well after the patient had completed TAVI. The use of the Claret CE Pro™ system is feasible and safe. Capture of debris in more than half of the patients provides evidence for the potential to reduce the procedural cerebral embolic burden utilising this dedicated filter

  9. High-Fidelity Piezoelectric Audio Device

    Science.gov (United States)

    Woodward, Stanley E.; Fox, Robert L.; Bryant, Robert G.

    2003-01-01

    ModalMax is a very innovative means of harnessing the vibration of a piezoelectric actuator to produce an energy efficient low-profile device with high-bandwidth high-fidelity audio response. The piezoelectric audio device outperforms many commercially available speakers made using speaker cones. The piezoelectric device weighs substantially less (4 g) than the speaker cones which use magnets (10 g). ModalMax devices have extreme fabrication simplicity. The entire audio device is fabricated by lamination. The simplicity of the design lends itself to lower cost. The piezoelectric audio device can be used without its acoustic chambers and thereby resulting in a very low thickness of 0.023 in. (0.58 mm). The piezoelectric audio device can be completely encapsulated, which makes it very attractive for use in wet environments. Encapsulation does not significantly alter the audio response. Its small size (see Figure 1) is applicable to many consumer electronic products, such as pagers, portable radios, headphones, laptop computers, computer monitors, toys, and electronic games. The audio device can also be used in automobile or aircraft sound systems.

  10. Deformable paper origami optoelectronic devices

    KAUST Repository

    He, Jr-Hau

    2017-01-19

    Deformable optoelectronic devices are provided, including photodetectors, photodiodes, and photovoltaic cells. The devices can be made on a variety of paper substrates, and can include a plurality of fold segments in the paper substrate creating a deformable pattern. Thin electrode layers and semiconductor nanowire layers can be attached to the substrate, creating the optoelectronic device. The devices can be highly deformable, e.g. capable of undergoing strains of 500% or more, bending angles of 25° or more, and/or twist angles of 270° or more. Methods of making the deformable optoelectronic devices and methods of using, e.g. as a photodetector, are also provided.

  11. Temperature indicating device

    International Nuclear Information System (INIS)

    Angus, J.P.; Salt, D.

    1988-01-01

    A temperature indicating device comprises a plurality of planar elements some undergoing a reversible change in appearance at a given temperature the remainder undergoing an irreversible change in appearance at a given temperature. The device is useful in indicating the temperature which an object has achieved as well as its actual temperature. The reversible change is produced by liquid crystal devices. The irreversible change is produced by an absorbent surface carrying substances e.g. waxes which melt at predetermined temperatures and are absorbed by the surface; alternatively paints may be used. The device is used for monitoring processes of encapsulation of radio active waste. (author)

  12. High frequency jet ventilation through a supraglottic airway device: a case series of patients undergoing extra-corporeal shock wave lithotripsy.

    Science.gov (United States)

    Canty, D J; Dhara, S S

    2009-12-01

    High frequency jet ventilation has been shown to be beneficial during extra-corporeal shock wave lithotripsy as it reduces urinary calculus movement which increases lithotripsy efficiency with better utilisation of shockwave energy and less patient exposure to tissue trauma. In all reports, sub-glottic high frequency jet ventilation was delivered through a tracheal tube or a jet catheter requiring paralysis and direct laryngoscopy. In this study, a simple method using supraglottic jet ventilation through a laryngeal mask attached to a circle absorber anaesthetic breathing system is described. The technique avoids the need for dense neuromuscular blockade for laryngoscopy and the potential complications associated with sub-glottic instrumentation and sub-glottic jet ventilation. The technique was successfully employed in a series of patients undergoing lithotripsy under general anaesthesia as an outpatient procedure.

  13. High energy devices versus low energy devices in orthopedics treatment modalities

    Science.gov (United States)

    Schultheiss, Reiner

    2003-10-01

    The orthopedic consensus group defined in 1997 the 42 most likely relevant parameters of orthopedic shock wave devices. The idea of this approach was to correlate the different clinical outcomes with the physical properties of the different devices with respect to their acoustical waves. Several changes in the hypothesis of the dose effect relationship have been noticed since the first orthopedic treatments. The relation started with the maximum pressure p+, followed by the total energy, the energy density; and finally the single treatment approach using high, and then the multiple treatment method using low energy. Motivated by the reimbursement situation in Germany some manufacturers began to redefine high and low energy devices independent of the treatment modality. The OssaTron as a high energy, single treatment electro hydraulic device gained FDA approval as the first orthopedic ESWT device for plantar fasciitis and, more recently, for lateral epicondylitis. Two low energy devices have now also gained FDA approval based upon a single treatment. Comparing the acoustic data, differences between the OssaTron and the other devices are obvious and will be elaborated upon. Cluster analysis of the outcomes and the acoustical data are presented and new concepts will be suggested.

  14. Advanced High Voltage Power Device Concepts

    CERN Document Server

    Baliga, B Jayant

    2012-01-01

    Advanced High Voltage Power Device Concepts describes devices utilized in power transmission and distribution equipment, and for very high power motor control in electric trains and steel-mills. Since these devices must be capable of supporting more than 5000-volts in the blocking mode, this books covers operation of devices rated at 5,000-V, 10,000-V and 20,000-V. Advanced concepts (the MCT, the BRT, and the EST) that enable MOS-gated control of power thyristor structures are described and analyzed in detail. In addition, detailed analyses of the silicon IGBT, as well as the silicon carbide MOSFET and IGBT, are provided for comparison purposes. Throughout the book, analytical models are generated to give a better understanding of the physics of operation for all the structures. This book provides readers with: The first comprehensive treatment of high voltage (over 5000-volts) power devices suitable for the power distribution, traction, and motor-control markets;  Analytical formulations for all the device ...

  15. Application of high power microwave vacuum electron devices

    International Nuclear Information System (INIS)

    Ding Yaogen; Liu Pukun; Zhang Zhaochuan; Wang Yong; Shen Bin

    2011-01-01

    High power microwave vacuum electron devices can work at high frequency, high peak and average power. They have been widely used in military and civil microwave electron systems, such as radar, communication,countermeasure, TV broadcast, particle accelerators, plasma heating devices of fusion, microwave sensing and microwave heating. In scientific research, high power microwave vacuum electron devices are used mainly on high energy particle accelerator and fusion research. The devices include high peak power klystron, CW and long pulse high power klystron, multi-beam klystron,and high power gyrotron. In national economy, high power microwave vacuum electron devices are used mainly on weather and navigation radar, medical and radiation accelerator, TV broadcast and communication system. The devices include high power pulse and CW klystron, extended interaction klystron, traveling wave tube (TWT), magnetron and induced output tube (IOT). The state of art, common technology problems and trends of high power microwave vacuum electron devices are introduced in this paper. (authors)

  16. High performance bio-integrated devices

    Science.gov (United States)

    Kim, Dae-Hyeong; Lee, Jongha; Park, Minjoon

    2014-06-01

    In recent years, personalized electronics for medical applications, particularly, have attracted much attention with the rise of smartphones because the coupling of such devices and smartphones enables the continuous health-monitoring in patients' daily life. Especially, it is expected that the high performance biomedical electronics integrated with the human body can open new opportunities in the ubiquitous healthcare. However, the mechanical and geometrical constraints inherent in all standard forms of high performance rigid wafer-based electronics raise unique integration challenges with biotic entities. Here, we describe materials and design constructs for high performance skin-mountable bio-integrated electronic devices, which incorporate arrays of single crystalline inorganic nanomembranes. The resulting electronic devices include flexible and stretchable electrophysiology electrodes and sensors coupled with active electronic components. These advances in bio-integrated systems create new directions in the personalized health monitoring and/or human-machine interfaces.

  17. DEVICE FOR CONTROL OF OXYGEN PARTIAL PRESSURE

    Science.gov (United States)

    Bradner, H.; Gordon, H.S.

    1957-12-24

    A device is described that can sense changes in oxygen partial pressure and cause a corresponding mechanical displacement sufficient to actuate meters, valves and similar devices. A piston and cylinder arrangement contains a charge of crystalline metal chelate pellets which have the peculiar property of responding to variations in the oxygen content of the ambient atmosphere by undergoing a change in dimension. A lever system amplifies the relative displacement of the piston in the cylinder, and actuates the controlled valving device. This partial pressure oxygen sensing device is useful in controlled chemical reactions or in respiratory devices such as the oxygen demand meters for high altitude aircraft.

  18. Safety and performance of a novel embolic deflection device in patients undergoing transcatheter aortic valve replacement: results from the DEFLECT I study.

    Science.gov (United States)

    Baumbach, Andreas; Mullen, Michael; Brickman, Adam M; Aggarwal, Suneil K; Pietras, Cody G; Forrest, John K; Hildick-Smith, David; Meller, Stephanie M; Gambone, Louise; den Heijer, Peter; Margolis, Pauliina; Voros, Szilard; Lansky, Alexandra J

    2015-05-01

    This study aimed to evaluate the safety and performance of the TriGuard™ Embolic Deflection Device (EDD), a nitinol mesh filter positioned in the aortic arch across all three major cerebral artery take-offs to deflect emboli away from the cerebral circulation, in patients undergoing transcatheter aortic valve replacement (TAVR). The prospective, multicentre DEFLECT I study (NCT01448421) enrolled 37 consecutive subjects undergoing TAVR with the TriGuard EDD. Subjects underwent clinical and cognitive follow-up to 30 days; cerebral diffusion-weighted magnetic resonance imaging (DW-MRI) was performed pre-procedure and at 4±2 days post procedure. The device performed as intended with successful cerebral coverage in 80% (28/35) of cases. The primary safety endpoint (in-hospital EDD device- or EDD procedure-related cardiovascular mortality, major stroke disability, life-threatening bleeding, distal embolisation, major vascular complications, or need for acute cardiac surgery) occurred in 8.1% of subjects (VARC-defined two life-threatening bleeds and one vascular complication). The presence of new cerebral ischaemic lesions on post-procedure DW-MRI (n=28) was similar to historical controls (82% vs. 76%, p=NS). However, an exploratory analysis found that per-patient total lesion volume was 34% lower than reported historical data (0.2 vs. 0.3 cm3), and 89% lower in patients with complete (n=17) versus incomplete (n=10) cerebral vessel coverage (0.05 vs. 0.45 cm3, p=0.016). Use of the first-generation TriGuard EDD during TAVR is safe, and device performance was successful in 80% of cases during the highest embolic-risk portions of the TAVR procedure. The potential of the TriGuard EDD to reduce total cerebral ischaemic burden merits further randomised investigation.

  19. Systematic review: comparative effectiveness of adjunctive devices in patients with ST-segment elevation myocardial infarction undergoing percutaneous coronary intervention of native vessels

    Directory of Open Access Journals (Sweden)

    Sobieraj Diana M

    2011-12-01

    Full Text Available Abstract Background During percutaneous coronary intervention (PCI, dislodgement of atherothrombotic material from coronary lesions can result in distal embolization, and may lead to increased major adverse cardiovascular events (MACE and mortality. We sought to systematically review the comparative effectiveness of adjunctive devices to remove thrombi or protect against distal embolization in patients with ST-segment elevation myocardial infarction (STEMI undergoing PCI of native vessels. Methods We conducted a systematic literature search of Medline, the Cochrane Database, and Web of Science (January 1996-March 2011, http://www.clinicaltrials.gov, abstracts from major cardiology meetings, TCTMD, and CardioSource Plus. Two investigators independently screened citations and extracted data from randomized controlled trials (RCTs that compared the use of adjunctive devices plus PCI to PCI alone, evaluated patients with STEMI, enrolled a population with 95% of target lesion(s in native vessels, and reported data on at least one pre-specified outcome. Quality was graded as good, fair or poor and the strength of evidence was rated as high, moderate, low or insufficient. Disagreement was resolved through consensus. Results 37 trials met inclusion criteria. At the maximal duration of follow-up, catheter aspiration devices plus PCI significantly decreased the risk of MACE by 27% compared to PCI alone. Catheter aspiration devices also significantly increased the achievement of ST-segment resolution by 49%, myocardial blush grade of 3 (MBG-3 by 39%, and thrombolysis in myocardial infarction (TIMI 3 flow by 8%, while reducing the risk of distal embolization by 44%, no reflow by 48% and coronary dissection by 70% versus standard PCI alone. In a majority of trials, the use of catheter aspiration devices increased procedural time upon qualitative assessment. Distal filter embolic protection devices significantly increased the risk of target revascularization

  20. Plasma Photonic Devices for High Energy Density Science

    International Nuclear Information System (INIS)

    Kodama, R.

    2005-01-01

    High power laser technologies are opening a variety of attractive fields of science and technology using high energy density plasmas such as plasma physics, laboratory astrophysics, material science, nuclear science including medical applications and laser fusion. The critical issues in the applications are attributed to the control of intense light and enormous density of charged particles including efficient generation of the particles such as MeV electrons and protons with a current density of TA/cm2. Now these application possibilities are limited only by the laser technology. These applications have been limited in the control of the high power laser technologies and their optics. However, if we have another device consisted of the 4th material, i.e. plasma, we will obtain a higher energy density condition and explore the application possibilities, which could be called high energy plasma device. One of the most attractive devices has been demonstrated in the fast ignition scheme of the laser fusion, which is cone-guiding of ultra-intense laser light in to high density regions1. This is one of the applications of the plasma device to control the ultra-intense laser light. The other role of the devices consisted of transient plasmas is control of enormous energy-density particles in a fashion analogous to light control with a conventional optical device. A plasma fibre (5?m/1mm), as one example of the devices, has guided and deflected the high-density MeV electrons generated by ultra-intense laser light 2. The electrons have been well collimated with either a lens-like plasma device or a fibre-like plasma, resulting in isochoric heating and creation of ultra-high pressures such as Giga bar with an order of 100J. Plasmas would be uniquely a device to easily control the higher energy density particles like a conventional optical device as well as the ultra-intense laser light, which could be called plasma photonic device. (Author)

  1. Efficacy of Mobile Health Care Application and Wearable Device in Improvement of Physical Performance in Colorectal Cancer Patients Undergoing Chemotherapy.

    Science.gov (United States)

    Cheong, In Yae; An, So Yeon; Cha, Won Chul; Rha, Mi Yong; Kim, Seung Tae; Chang, Dong Kyung; Hwang, Ji Hye

    2018-06-01

    The use of a mobile health care application, the delivery of health care or health care-related services through the use of portable devices, to manage functional loss, treatment-related toxicities, and impaired quality of life in cancer patients during chemotherapy through supervised self-management has been increasing. The aim of the present study was to evaluate the efficacy and feasibility of comprehensive mobile health care using a tailored rehabilitation program for colorectal cancer patients undergoing active chemotherapy. A total of 102 colorectal cancer patients undergoing chemotherapy underwent 12 weeks of smartphone aftercare through provision of a mobile application and wearable device that included a rehabilitation exercise program and information on their disease and treatment. The grip strength test, 30-second chair stand test, 2-minute walk test, amount of physical activity (International Physical Activity Questionnaire short-form), quality of life (European Organization for Research and Treatment of Cancer Quality of Life Questionnaire C30), and nutritional status (Patient-generated Subjective Global Assessment) were assessed and measured at baseline, at mid-intervention (6 weeks), and at completion of the intervention (12 weeks). The rehabilitation exercise intensity was adjusted by the test results at every assessment and through real-time communication between the patients and clinicians. Of the 102 patients, 75 completed all 12 weeks of the smartphone aftercare rehabilitation program. The lower extremity strength (P mobile health care application was effective in improving patients' physical capacity and treatment-related symptoms even during active chemotherapy. Copyright © 2018 Elsevier Inc. All rights reserved.

  2. Construction of a dog training device with high frequency and high power pulses

    International Nuclear Information System (INIS)

    Viaud Trejos, Rafael Alfonso

    2013-01-01

    An electronic device is built to produce high frequency and high power sound. The device is used in training and control of dogs. Commercial ultrasonic devices used for dog training are analyzed. The best strategies and components of the design are determined from an electronic device to produce sounds in frequency from 15kHz to 50Khz. Effectiveness tests are performed to establish the adequate design of the ultrasonic electronic device. The test results are analyzed to find opportunities of improvement in the design or construction of the device [es

  3. The ALICE TPC, a high resolution device for ultra-high particle multiplicities. Past, present and future

    Energy Technology Data Exchange (ETDEWEB)

    Ivanov, Marian [GSI Helmholtzzentrum fuer Schwerionenforschung GmbH (Germany); Collaboration: ALICE-Collaboration

    2015-07-01

    The Time Projection Chamber (TPC) of the ALICE apparatus is a large 3-dimensional tracking and particle identification device for ultra-high multiplicity collision events. It has been operated successfully at the Large Hadron Collider (LHC) at CERN, recording data from pp, p-Pb, and Pb-Pb collisions. Presently, LHC is in its first long shutdown (LS1), the next round of data taking will start in summer 2015 at or close to the LHC design energy and luminosity. During the second long shutdown (LS2), LHC will undergo a further increase in the Pb-Pb luminosity together with a major upgrade of ALICE. After the upgrade, the ALICE TPC will operate with Pb-Pb collisions at an interaction rate of 50 kHz. We present the performance in operation, calibration and reconstruction with the ALICE TPC together with ongoing work and plans for the near future and the coming 10 years.

  4. High temperature electronic gain device

    International Nuclear Information System (INIS)

    McCormick, J.B.; Depp, S.W.; Hamilton, D.J.; Kerwin, W.J.

    1979-01-01

    An integrated thermionic device suitable for use in high temperature, high radiation environments is described. Cathode and control electrodes are deposited on a first substrate facing an anode on a second substrate. The substrates are sealed to a refractory wall and evacuated to form an integrated triode vacuum tube

  5. High temperature aqueous stress corrosion testing device

    International Nuclear Information System (INIS)

    Bornstein, A.N.; Indig, M.E.

    1975-01-01

    A description is given of a device for stressing tensile samples contained within a high temperature, high pressure aqueous environment, thereby permitting determination of stress corrosion susceptibility of materials in a simple way. The stressing device couples an external piston to an internal tensile sample via a pull rod, with stresses being applied to the sample by pressurizing the piston. The device contains a fitting/seal arrangement including Teflon and weld seals which allow sealing of the internal system pressure and the external piston pressure. The fitting/seal arrangement allows free movement of the pull rod and the piston

  6. High speed heterostructure devices

    CERN Document Server

    Beer, Albert C; Willardson, R K; Kiehl, Richard A; Sollner, T C L Gerhard

    1994-01-01

    Volume 41 includes an in-depth review of the most important, high-speed switches made with heterojunction technology. This volume is aimed at the graduate student or working researcher who needs a broad overview andan introduction to current literature. Key Features * The first complete review of InP-based HFETs and complementary HFETs, which promise very low power and high speed * Offers a complete, three-chapter review of resonant tunneling * Provides an emphasis on circuits as well as devices.

  7. Early Right Ventricular Assist Device Use in Patients Undergoing Continuous-Flow Left Ventricular Assist Device Implantation: Incidence and Risk Factors From the Interagency Registry for Mechanically Assisted Circulatory Support.

    Science.gov (United States)

    Kiernan, Michael S; Grandin, E Wilson; Brinkley, Marshall; Kapur, Navin K; Pham, Duc Thinh; Ruthazer, Robin; Rame, J Eduardo; Atluri, Pavan; Birati, Edo Y; Oliveira, Guilherme H; Pagani, Francis D; Kirklin, James K; Naftel, David; Kormos, Robert L; Teuteberg, Jeffrey J; DeNofrio, David

    2017-10-01

    To investigate preimplant risk factors associated with early right ventricular assist device (RVAD) use in patients undergoing continuous-flow left ventricular assist device (LVAD) surgery. Patients in the Interagency Registry for Mechanically Assisted Circulatory Support who underwent primary continuous-flow-LVAD surgery were examined for concurrent or subsequent RVAD implantation within 14 days of LVAD. Risk factors for RVAD implantation and the combined end point of RVAD or death within 14 days of LVAD were assessed with stepwise logistic regression. We compared survival between patients with and without RVAD using Kaplan-Meier method and Cox proportional hazards modeling. Of 9976 patients undergoing continuous-flow-LVAD implantation, 386 patients (3.9%) required an RVAD within 14 days of LVAD surgery. Preimplant characteristics associated with RVAD use included interagency registry for mechanically assisted circulatory support patient profiles 1 and 2, the need for preoperative extracorporeal membrane oxygenation or renal replacement therapy, severe preimplant tricuspid regurgitation, history of cardiac surgery, and concomitant procedures other than tricuspid valve repair at the time of LVAD. Hemodynamic determinants included elevated right atrial pressure, reduced pulmonary artery pulse pressure, and reduced stroke volume. The final model demonstrated good performance for both RVAD implant (area under the curve, 0.78) and the combined end point of RVAD or death within 14 days (area under the curve, 0.73). Compared with patients receiving an isolated LVAD, patients requiring RVAD had decreased 1- and 6-month survival: 78.1% versus 95.8% and 63.6% versus 87.9%, respectively ( P The need for RVAD implantation after LVAD is associated with indices of global illness severity, markers of end-organ dysfunction, and profiles of hemodynamic instability. © 2017 American Heart Association, Inc.

  8. Highly efficient red electrophosphorescent devices at high current densities

    International Nuclear Information System (INIS)

    Wu Youzhi; Zhu Wenqing; Zheng Xinyou; Sun, Runguang; Jiang Xueyin; Zhang Zhilin; Xu Shaohong

    2007-01-01

    Efficiency decrease at high current densities in red electrophosphorescent devices is drastically restrained compared with that from conventional electrophosphorescent devices by using bis(2-methyl-8-quinolinato)4-phenylphenolate aluminum (BAlq) as a hole and exciton blocker. Ir complex, bis(2-(2'-benzo[4,5-α]thienyl) pyridinato-N,C 3' ) iridium (acetyl-acetonate) is used as an emitter, maximum external quantum efficiency (QE) of 7.0% and luminance of 10000cd/m 2 are obtained. The QE is still as high as 4.1% at higher current density J=100mA/cm 2 . CIE-1931 co-ordinates are 0.672, 0.321. A carrier trapping mechanism is revealed to dominate in the process of electroluminescence

  9. Outcomes of Highly Sensitized Patients Undergoing Simultaneous Liver and Kidney Transplantation: A Single-Center Experience With Desensitization.

    Science.gov (United States)

    Steggerda, J A; Kang, A; Pan, S-H; Sundaram, V; Nissen, N N; Klein, A S; Todo, T; Annamalai, A; Vo, A; Jordan, S C; Kim, I K

    Preformed donor-specific human leukocyte antigen antibodies (DSAs) in patients undergoing simultaneous liver and kidney transplantation (SLKT) are an independent risk factor for poorer patient and renal allograft survival. The outcomes of patients highly sensitized (HS) against HLA antigens undergoing SLKT and select HS SLKT recipients undergoing desensitization at a high-volume desensitization center were investigated. Seventy-five patients undergoing SLKT at a high-volume desensitization center between January 1, 2001, and December 31, 2015, were retrospectively reviewed. HS patients were defined by panel-reactive antibody (PRA) >30% (n = 17 patients), 11 of whom received pre- or perioperative desensitization with high-dose intravenous immunoglobulin (IVIG) ± rituximab. HS patients had significantly higher class I and class II PRA (class I = 41.3% ± 40.0% vs 2.5% ± 6.3%; class II = 45.7% ± 36.4% vs 1.0% ± 2.9%; P Desensitization in select HS SLKT patients was well tolerated but did not improve patient and allograft survival or significantly curtail rejection. HS SLKT recipients demonstrated increased allograft rejection, particularly CMR, but patient and graft survival were not impacted in the first year post-transplant. Select HS SLKT patients tolerated desensitization with high-dose IVIG ± rituximab and may have received additional immunoprotection against ABMR but survival was not affected. Copyright © 2017 Elsevier Inc. All rights reserved.

  10. A graphene integrated highly transparent resistive switching memory device

    Science.gov (United States)

    Dugu, Sita; Pavunny, Shojan P.; Limbu, Tej B.; Weiner, Brad R.; Morell, Gerardo; Katiyar, Ram S.

    2018-05-01

    We demonstrate the hybrid fabrication process of a graphene integrated highly transparent resistive random-access memory (TRRAM) device. The indium tin oxide (ITO)/Al2O3/graphene nonvolatile memory device possesses a high transmittance of >82% in the visible region (370-700 nm) and exhibits stable and non-symmetrical bipolar switching characteristics with considerably low set and reset voltages (ITO/Al2O3/Pt device and studied its switching characteristics for comparison and a better understanding of the ITO/Al2O3/graphene device characteristics. The conduction mechanisms in high and low resistance states were analyzed, and the observed polarity dependent resistive switching is explained based on electro-migration of oxygen ions.

  11. Optical analog transmission device

    International Nuclear Information System (INIS)

    Ikawa, Shinji.

    1994-01-01

    The present invention concerns a device such as electro-optical conversion elements, optoelectric-electric elements and optical transmission channel, not undergoing deleterious effects on the efficiency of conversion and transmission due to temperature, and aging change. That is, a sine wave superposing means superposes, on a detector signal to be transmitted, a sine-wave signal having a predetermined amplitude and at a frequency lower than that of the detector signal. An optoelectric conversion means converts the electric signal as the signal of the sine-wave signal superposing means into an optical signal and outputs the same to an optical transmitting channel. The optoelectric conversion means converts the transmitted signal to an electric signal. A discriminating means discriminates the electric signal into a detector signal and a sine-wave signal. A calculating means calculates an optical transmitting efficiency of the transmitting channel based on the amplitude of the discriminated sine-wave signal. A processing means compensates an amplitude value of the detector signals discriminated by the discriminating means based on the optical transmission efficiency. As a result, an optical analog transmission device can be attained, which conducts optical transmission at a high accuracy without undergoing the defective effects of the optical transmission efficiency. (I.S.)

  12. 14 CFR 25.345 - High lift devices.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false High lift devices. 25.345 Section 25.345... devices. (a) If wing flaps are to be used during takeoff, approach, or landing, at the design flap speeds.... The analysis must take into account the unsteady aerodynamic characteristics and rigid body motions of...

  13. HARD - The High Assurance Remote Authentication Device Project

    OpenAIRE

    2006-01-01

    The HARD project will build and evaluate a high assurance network access device. The purpose of this device is to provide an unforgeable trusted path with which network clients can securely interact with security-enabled remote servers.

  14. The demographic characteristics of high-level and recreational athletes undergoing hip arthroscopy for femoroacetabular impingement: a sports-specific analysis.

    Science.gov (United States)

    Nawabi, Danyal H; Bedi, Asheesh; Tibor, Lisa M; Magennis, Erin; Kelly, Bryan T

    2014-03-01

    The purpose of this study was to determine differences in age, gender, and the need for bilateral surgery between high-level athletes grouped by sports with similar mechanical demands on the hip and recreational athletes undergoing hip arthroscopy for femoroacetabular impingement (FAI). By use of a hip-preservation center registry, a retrospective review of patients undergoing hip arthroscopy for FAI between March 2010 and April 2012 was performed. Athletes were categorized as high level (high school, collegiate, or professional) or recreational. We performed a subgroup analysis for high-level athletes, looking at differences among contact, cutting, impingement, overhead/asymmetric, endurance, and flexibility sports. The study included 288 high-level athletes and 334 recreational athletes. Being a high-level athlete was associated with a younger age (mean age, 20.2 years v 33.0 years; odds ratio, 0.69; P gender (61.5% v 53.6%; odds ratio, 1.75; P = .03). The percentage of high-level athletes undergoing bilateral surgery was higher than that of recreational athletes (28.4% v 15.9%); however, this association was found to be confounded by age on multivariate analysis. The most common sports for high-level athletes were soccer, hockey, and football. Athletes participating in cutting sports were significantly younger than athletes participating flexibility, contact, or impingement sports. When compared with recreational athletes undergoing arthroscopic treatment for FAI, high-level athletes are more likely to be younger, to be male, and to undergo bilateral surgery. When high-level athletes are grouped by the mechanical demands placed on the hip by their sport, athletes participating in cutting sports are more likely to be younger than those in the other groups. Level IV, case series. Copyright © 2014 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  15. Predictive Factors for Patients Undergoing ASD Device Occlusion Who "Crossover" to Surgery.

    Science.gov (United States)

    Mulukutla, Venkatachalam; Qureshi, Athar M; Pignatelli, Ricardo; Ing, Frank F

    2018-03-01

    The aim of this study was to define characteristics of those patients who are referred for device closure of an Atrial septal defect (ASD), but identified to "crossover" surgery. All patients who underwent surgical and device (Amplatzer or Helex occluder) closures of secundum ASDs from 2001 to 2010 were reviewed and organized into three groups: surgical closure, device closure, and "crossover" group. 369 patients underwent ASD closure (265 device, 104 surgical). 42 of the 265 patients referred for device closure "crossed over" to the surgical group at various stages of the catheterization procedure. The device group had defect size measuring 14.2 mm (mean) and an ASD index (Defect Size (mm)/BSA) of 14.0 compared to the corresponding values in the surgical group (20.1 mm, ASD index 25.9) (P ASD index) (P ASD index of 14.7 compared with the crossover group ASD index of 23.8 (P ASD index greater than 23.7 had a 90% specificity in "crossing over" to surgery. The crossover and surgical groups had statistically larger ASD defect size indexes compared with the device group. Deficient rim in the posterior/inferior rim is associated with a large ASD size index which is a predictive factor for crossing over to surgery. Catheterization did not negatively impact surgical results in the "crossover" group.

  16. What is the fate of artificial urinary sphincters among men undergoing repetitive bladder cancer treatment?

    Directory of Open Access Journals (Sweden)

    S. Mitchell Heiner

    2018-01-01

    Full Text Available Purpose: Functional characteristics and durability of the artificial urinary sphincter (AUS among patients who develop bladder cancer has been poorly characterized. We sought to evaluate AUS outcomes among patients subsequently diagnosed with bladder cancer, in order to describe device survivability when subject to diagnostic and therapeutic procedures such as cystoscopy, transurethral resection, and cystectomy. Materials and Methods: We retrospectively reviewed 1,803 male patients treated with AUS surgery at a single institution between 1983–2014. We describe AUS device outcomes among patients undergoing surveillance and treatment for bladder cancer. Results: Following AUS placement, 14 (0.8% patients were subsequently diagnosed with and treated for bladder cancer and 4 patients with bladder cancer undergoing treatment and screening, subsequently received AUS placement. The median follow-up from device placement was 7.2 years (interquartile range [IQR], 2.8–11.5, and the median time from AUS placement to bladder cancer diagnosis was 6 (IQR, 0–9. There were a total of 8 primary and 1 secondary devices failures. Despite a median of 2 diagnostic cystoscopies (IQR, 1–6 and 0 bladder tumor resections (IQR, 0–0 per patient following device implantation, only 1 (5.6% patient experienced an iatrogenic erosion related to urethral manipulation. Among those undergoing cystectomy (n=4, 1 device was left in situ without complication. Conclusions: Bladder cancer surveillance and treatment with an AUS device in place appears to confer minimal additional risk to AUS survival. Careful attention should be given to device deactivation and use of the smallest caliber instruments available to minimize the risk of iatrogenic urethral erosion.

  17. Tungsten as a Chemically-Stable Electrode Material on Ga-Containing Piezoelectric Substrates Langasite and Catangasite for High-Temperature SAW Devices

    Directory of Open Access Journals (Sweden)

    Gayatri K. Rane

    2016-02-01

    Full Text Available Thin films of tungsten on piezoelectric substrates La3Ga5SiO14 (LGS and Ca3TaGa3Si2O14 (CTGS have been investigated as a potential new electrode material for interdigital transducers for surface acoustic wave-based sensor devices operating at high temperatures up to 800 °C under vacuum conditions. Although LGS is considered to be suitable for high-temperature applications, it undergoes chemical and structural transformation upon vacuum annealing due to diffusion of gallium and oxygen. This can alter the device properties depending on the electrode nature, the annealing temperature, and the duration of the application. Our studies present evidence for the chemical stability of W on these substrates against the diffusion of Ga/O from the substrate into the film, even upon annealing up to 800 °C under vacuum conditions using Auger electron spectroscopy and energy-dispersive X-ray spectroscopy, along with local studies using transmission electron microscopy. Additionally, the use of CTGS as a more stable substrate for such applications is indicated.

  18. System constitution of plasma high frequency heating device and element equipment

    International Nuclear Information System (INIS)

    Nagashima, Takashi

    1988-01-01

    On the high frequency heating device used for nuclear fusion experiment, the system constitution and the main items of development for the element equipment are described. As for the high frequency heating device, large technical progress was observed in the past 10 years as the second stage heating for tokamaks and one of the main means of current drive. At present, three frequency zones are regarded as promising for plasma high frequency heating in large nuclear fusion devices, and the experiment of 10 MW class is in progress at JT-60, JET and so on. There are electron cyclotron heating, lower hybrid resonance frequency heating and ion cyclotron range of frquency heating. The basic constitution of these heating devices includes a high frequency source, a transmission system, a connection system, and a common system for control, cooling, record and others. The ECH device using gyrotrons of several tens GHz, the LHRF heating device using large power klystrons up to several GHz and the ICRF heating device up to 200 MHz are briefly explained. The main element equipments composing the high frequency heating systems of several tens MW are discussed. (Kako, I.)

  19. A Proactive Approach to High Risk Delirium Patients Undergoing Total Joint Arthroplasty.

    Science.gov (United States)

    Duque, Andres F; Post, Zachary D; Orozco, Fabio R; Lutz, Rex W; Ong, Alvin C

    2018-04-01

    Delirium is a common complication among elderly patients undergoing total joint arthroplasty (TJA). Its incidence has been reported from 4% to 53%. The Centers for Medicare and Medicaid Services consider delirium following TJA a "never-event." The purpose of this study is to evaluate a simple perioperative protocol used to identify delirium risk patients and prevent its incidence following TJA. Our group developed a protocol to identify and prevent delirium in patients undergoing TJA. All patients were screened and scored in the preoperative assessment, on criteria such as age, history of forgetfulness, history of agitation or visual hallucinations, history of falls, history of postoperative confusion, and inability to perform higher brain functions. Patients were scored on performance in a simple mental examination. The patients were classified as low, medium, or high risk. Patients who were identified as high risk were enrolled in a delirium avoidance protocol that minimized narcotics and emphasized nursing involvement and fluids administration. Five of 7659 (0.065%) consecutive TJA patients from 2010 to 2015 developed delirium. A total of 422 patients were identified as high risk. All 5 patients who suffered delirium were within the high risk group. No low or medium risk patients suffered a delirium complication. Three (0.039%) patients suffered drug-induced delirium, 1 (0.013%) had delirium related to alcohol withdrawal, and 1 (0.013%) had delirium after a systemic infection. This protocol is effective in identifying patients at high delirium risk and diminishing the incidence of this complication by utilizing a simple screening tool and perioperative protocol. Copyright © 2017 Elsevier Inc. All rights reserved.

  20. Two Different Maintenance Strategies in the Hospital Environment: Preventive Maintenance for Older Technology Devices and Predictive Maintenance for Newer High-Tech Devices.

    Science.gov (United States)

    Sezdi, Mana

    2016-01-01

    A maintenance program generated through the consideration of characteristics and failures of medical equipment is an important component of technology management. However, older technology devices and newer high-tech devices cannot be efficiently managed using the same strategies because of their different characteristics. This study aimed to generate a maintenance program comprising two different strategies to increase the efficiency of device management: preventive maintenance for older technology devices and predictive maintenance for newer high-tech devices. For preventive maintenance development, 589 older technology devices were subjected to performance verification and safety testing (PVST). For predictive maintenance development, the manufacturers' recommendations were used for 134 high-tech devices. These strategies were evaluated in terms of device reliability. This study recommends the use of two different maintenance strategies for old and new devices at hospitals in developing countries. Thus, older technology devices that applied only corrective maintenance will be included in maintenance like high-tech devices.

  1. Echocardiographic predictors of coil vs device closure in patients undergoing percutaneous patent ductus arteriosus closure.

    Science.gov (United States)

    Roushdy, Alaa; Abd El Razek, Yasmeen; Mamdouh Tawfik, Ahmed

    2018-01-01

    To determine anatomic and hemodynamic echocardiographic predictors for patent ductus arteriosus (PDA) device vs coil closure. Seventy-six patients who were referred for elective transcatheter PDA closure were enrolled in the study. All patients underwent full echocardiogram including measurement of the PDA pulmonary end diameter, color flow width and extent, peak and end-diastolic Doppler gradients across the duct, diastolic flow reversal, left atrial dimensions and volume, left ventricular sphericity index, and volumes. The study group was subdivided into 2 subgroups based on the mode of PDA closure whether by coil (n = 42) or device (n = 34). Using univariate analysis there was a highly significant difference between the 2 groups as regard the pulmonary end diameter measured in both the suprasternal and parasternal short-axis views as well as the color flow width and color flow extent (P closure group had statistically significant higher end-systolic and end-diastolic volumes indexed, left atrial volume, and diastolic flow reversal. Receiver operating characteristic curve analysis showed a pulmonary end diameter cutoff point from the suprasternal view > 2.5 mm and from parasternal short-axis view > 2.61 mm to have the highest balanced sensitivity and specificity to predict the likelihood for device closure (AUC 0.971 and 0.979 respectively). The pulmonary end diameter measured from the suprasternal view was the most independent predictor of device closure. The selection between PDA coil or device closure can be done on the basis of multiple anatomic and hemodynamic echocardiographic variables. © 2017 Wiley Periodicals, Inc.

  2. High-risk medical devices, children and the FDA: regulatory challenges facing pediatric mechanical circulatory support devices.

    Science.gov (United States)

    Almond, Christopher S D; Chen, Eric A; Berman, Michael R; Less, Joanne R; Baldwin, J Timothy; Linde-Feucht, Sarah R; Hoke, Tracey R; Pearson, Gail D; Jenkins, Kathy; Duncan, Brian W; Zuckerman, Bram D

    2007-01-01

    Pediatric mechanical circulatory support is a critical unmet need in the United States. Infant- and child-sized ventricular assist devices are currently being developed largely through federal contracts and grants through the National Heart, Lung, and Blood Institute (NHLBI). Human testing and marketing of high-risk devices for children raises epidemiologic and regulatory issues that will need to be addressed. Leaders from the US Food and Drug Administration (FDA), NHLBI, academic pediatric community, and industry convened in January 2006 for the first FDA Workshop on the Regulatory Process for Pediatric Mechanical Circulatory Support Devices. The purpose was to provide the pediatric community with an overview of the federal regulatory process for high-risk medical devices and to review the challenges specific to the development and regulation of pediatric mechanical circulatory support devices. Pediatric mechanical circulatory support present significant epidemiologic, logistic, and financial challenges to industry, federal regulators, and the pediatric community. Early interactions with the FDA, shared appreciation of challenges, and careful planning will be critical to avoid unnecessary delays in making potentially life-saving devices available for children. Collaborative efforts to address these challenges are warranted.

  3. A high-efficiency solution-deposited thin-film photovoltaic device

    Energy Technology Data Exchange (ETDEWEB)

    Mitzi, David B; Yuan, Min; Liu, Wei; Chey, S Jay; Schrott, Alex G [IBM T. J. Watson Research Center, Yorktown Heights, NY (United States); Kellock, Andrew J; Deline, Vaughn [IBM Almaden Research Center, San Jose, CA (United States)

    2008-10-02

    High-quality Cu(In,Ga)Se{sub 2} (CIGS) films are deposited from hydrazine-based solutions and are employed as absorber layers in thin-film photovoltaic devices. The CIGS films exhibit tunable stoichiometry and well-formed grain structure without requiring post-deposition high-temperature selenium treatment. Devices based on these films offer power conversion efficiencies of 10% (AM1.5 illumination). (Abstract Copyright [2008], Wiley Periodicals, Inc.)

  4. Characteristics of Clinical Studies Used for US Food and Drug Administration Approval of High-Risk Medical Device Supplements.

    Science.gov (United States)

    Zheng, Sarah Y; Dhruva, Sanket S; Redberg, Rita F

    2017-08-15

    High-risk medical devices often undergo modifications, which are approved by the US Food and Drug Administration (FDA) through various kinds of premarket approval (PMA) supplements. There have been multiple high-profile recalls of devices approved as PMA supplements. To characterize the quality of the clinical studies and data (strength of evidence) used to support FDA approval of panel-track supplements (a type of PMA supplement pathway that is used for significant changes in a device or indication for use and always requires clinical data). Descriptive study of clinical studies supporting panel-track supplements approved by the FDA between April 19, 2006, and October 9, 2015. Panel-track supplement approval. Methodological quality of studies including randomization, blinding, type of controls, clinical vs surrogate primary end points, use of post hoc analyses, and reporting of age and sex. Eighty-three clinical studies supported the approval of 78 panel-track supplements, with 71 panel-track supplements (91%) supported by a single study. Of the 83 studies, 37 (45%) were randomized clinical trials and 25 (30%) were blinded. The median number of patients per study was 185 (interquartile range, 75-305), and the median follow-up duration was 180 days (interquartile range, 84-270 days). There were a total of 150 primary end points (mean [SD], 1.8 [1.2] per study), and 57 primary end points (38%) were compared with controls. Of primary end points with controls, 6 (11%) were retrospective controls and 51 (89%) were active controls. One hundred twenty-one primary end points (81%) were surrogate end points. Thirty-three studies (40%) did not report age and 25 (30%) did not report sex for all enrolled patients. The FDA required postapproval studies for 29 of 78 (37%) panel-track supplements. Among clinical studies used to support FDA approval of high-risk medical device modifications, fewer than half were randomized, blinded, or controlled, and most primary outcomes were

  5. High intensity discharge device containing oxytrihalides

    Science.gov (United States)

    Lapatovich, W.P.; Keeffe, W.M.; Liebermann, R.W.; Maya, J.

    1987-06-09

    A fill composition for a high intensity discharge device including mercury, niobium oxytrihalide, and a molecular stabilization agent is provided. The molar ratio of niobium oxytrihalide to the molecular stabilization agent in the fill is in the range of from about 5:1 to about 7.5:1. Niobium oxytrihalide is present in the fill in sufficient amount to produce, by dissociation in the discharge, atomic niobium, niobium oxide, NbO, and niobium dioxide, NbO[sub 2], with the molar ratio of niobium-containing vapor species to mercury in the fill being in the range of from about 0.01:1 to about 0.50:1; and mercury pressure of about 1 to about 50 atmospheres at lamp operating temperature. There is also provided a high intensity discharge device comprising a sealed light-transmissive arc tube; the arc tube including the above-described fill; and an energizing means for producing an electric discharge within the arc tube. 7 figs.

  6. Positioning device for MRI-guided high intensity focused ultrasound system

    Energy Technology Data Exchange (ETDEWEB)

    Damianou, Christakis [Frederick Institute of Technology (FIT), Limassol (Cyprus); MEDSONIC, LTD, Limassol (Cyprus); Ioannides, Kleanthis [Polikliniki Igia, Limassol (Cyprus); Milonas, Nicos [Frederick Institute of Technology (FIT), Limassol (Cyprus)

    2008-04-15

    A prototype magnetic resonance imaging (MRI)- compatible positioning device was used to move an MRI-guided high intensity focused ultrasound (HIFU) transducer. The positioning device has three user-controlled degrees of freedom that allow access to various targeted lesions. The positioning device was designed and fabricated using construction materials selected for compatibility with high magnetic fields and fast switching magnetic field gradients encountered inside MRI scanners. The positioning device incorporates only MRI compatible materials such as piezoelectric motors, plastic sheets, brass screws, plastic pulleys and timing belts. The HIFU/MRI system includes the multiple subsystems (a) HIFU system, (b) MR imaging, (c) Positioning device (robot) and associate drivers, (d) temperature measurement, (e) cavitation detection, (f) MRI compatible camera, and (g) Soft ware. The MRI compatibility of the system was successfully demonstrated in a clinical high-field MRI scanner. The ability of the robot to accurately move the transducer thus creating discrete and overlapping lesions in biological tissue was tested successfully. A simple, cost effective, portable positioning device has been developed which can be used in virtually any clinical MRI scanner since it can be sited on the scanner's table. The propagation of HIFU can use either a lateral or superior-inferior approach. Discrete and large lesions were created successfully with reproducible results. (orig.)

  7. FDA publishes checklist of Y2K high-risk devices.

    Science.gov (United States)

    1999-09-01

    Key points. The federal Food and Drug Administration (FDA) has developed a list of types of medical devices that have the potential for the most serious consequences for patients should they fail because of Y2K-related problems. This list of computer-controlled potentially high-risk devices can provide a guide to health care facilities regarding the types of devices that should receive priority in their assessment and remediation of medical devices. The list may change as the FDA receives comments on the types of devices included in the list.

  8. Multiscale Thermo-Mechanical Design and Analysis of High Frequency and High Power Vacuum Electron Devices

    Science.gov (United States)

    Gamzina, Diana

    Diana Gamzina March 2016 Mechanical and Aerospace Engineering Multiscale Thermo-Mechanical Design and Analysis of High Frequency and High Power Vacuum Electron Devices Abstract A methodology for performing thermo-mechanical design and analysis of high frequency and high average power vacuum electron devices is presented. This methodology results in a "first-pass" engineering design directly ready for manufacturing. The methodology includes establishment of thermal and mechanical boundary conditions, evaluation of convective film heat transfer coefficients, identification of material options, evaluation of temperature and stress field distributions, assessment of microscale effects on the stress state of the material, and fatigue analysis. The feature size of vacuum electron devices operating in the high frequency regime of 100 GHz to 1 THz is comparable to the microstructure of the materials employed for their fabrication. As a result, the thermo-mechanical performance of a device is affected by the local material microstructure. Such multiscale effects on the stress state are considered in the range of scales from about 10 microns up to a few millimeters. The design and analysis methodology is demonstrated on three separate microwave devices: a 95 GHz 10 kW cw sheet beam klystron, a 263 GHz 50 W long pulse wide-bandwidth sheet beam travelling wave tube, and a 346 GHz 1 W cw backward wave oscillator.

  9. High-intensity resistance and cardiovascular training improve physical capacity in cancer patients undergoing chemotherapy

    DEFF Research Database (Denmark)

    Quist, Morten; Rørth, Mikael Rahbek; Zacho, Morten

    2006-01-01

    The purpose of the study was to examine the effects of a supervised high- and low-intensity structured training program in cancer patients concurrently undergoing chemotherapy. Seventy patients, in different stages of the disease and with different diagnoses (48 females, 22 males), between 18...... and 65 years of age (mean age 42.8) participated in a 9-h weekly training program over 6 weeks. The intervention involved physical exercise, relaxation, massage, and body-awareness training. Physical capacity (one-repetition maximum tests (1RM), VO2max) and body composition (weight, skin-fold) were......-term study support the theory that exercise is a beneficial intervention strategy for increasing muscle strength and aerobic fitness during antineoplastic chemotherapy. This type of exercise program can be an important component of complementary treatment for cancer patients undergoing chemotherapy....

  10. High Resolution Tracking Devices Based on Capillaries Filled with Liquid Scintillator

    CERN Multimedia

    Bonekamper, D; Vassiltchenko, V; Wolff, T

    2002-01-01

    %RD46 %title\\\\ \\\\The aim of the project is to develop high resolution tracking devices based on thin glass capillary arrays filled with liquid scintillator. This technique provides high hit densities and a position resolution better than 20 $\\mu$m. Further, their radiation hardness makes them superior to other types of tracking devices with comparable performance. Therefore, the technique is attractive for inner tracking in collider experiments, microvertex devices, or active targets for short-lived particle detection. High integration levels in the read-out based on the use of multi-pixel photon detectors and the possibility of optical multiplexing allow to reduce considerably the number of output channels, and, thus, the cost for the detector.\\\\ \\\\New optoelectronic devices have been developed and tested: the megapixel Electron Bombarded CCD (EBCCD), a high resolution image-detector having an outstanding capability of single photo-electron detection; the Vacuum Image Pipeline (VIP), a high-speed gateable pi...

  11. Highly conductive paper for energy-storage devices

    KAUST Repository

    Hu, L.

    2009-12-07

    Paper, invented more than 2,000 years ago and widely used today in our everyday lives, is explored in this study as a platform for energy-storage devices by integration with 1D nanomaterials. Here, we show that commercially available paper can be made highly conductive with a sheet resistance as low as 1 ohm per square (Omega/sq) by using simple solution processes to achieve conformal coating of single-walled carbon nanotube (CNT) and silver nanowire films. Compared with plastics, paper substrates can dramatically improve film adhesion, greatly simplify the coating process, and significantly lower the cost. Supercapacitors based on CNT-conductive paper show excellent performance. When only CNT mass is considered, a specific capacitance of 200 F/g, a specific energy of 30-47 Watt-hour/kilogram (Wh/kg), a specific power of 200,000 W/kg, and a stable cycling life over 40,000 cycles are achieved. These values are much better than those of devices on other flat substrates, such as plastics. Even in a case in which the weight of all of the dead components is considered, a specific energy of 7.5 Wh/kg is achieved. In addition, this conductive paper can be used as an excellent lightweight current collector in lithium-ion batteries to replace the existing metallic counterparts. This work suggests that our conductive paper can be a highly scalable and low-cost solution for high-performance energy storage devices.

  12. High voltage semiconductor devices and methods of making the devices

    Energy Technology Data Exchange (ETDEWEB)

    Matocha, Kevin; Chatty, Kiran; Banerjee, Sujit

    2018-01-23

    A multi-cell MOSFET device including a MOSFET cell with an integrated Schottky diode is provided. The MOSFET includes n-type source regions formed in p-type well regions which are formed in an n-type drift layer. A p-type body contact region is formed on the periphery of the MOSFET. The source metallization of the device forms a Schottky contact with an n-type semiconductor region adjacent the p-type body contact region of the device. Vias can be formed through a dielectric material covering the source ohmic contacts and/or Schottky region of the device and the source metallization can be formed in the vias. The n-type semiconductor region forming the Schottky contact and/or the n-type source regions can be a single continuous region or a plurality of discontinuous regions alternating with discontinuous p-type body contact regions. The device can be a SiC device. Methods of making the device are also provided.

  13. Materials Challenges for High Performance Magnetocaloric Refrigeration Devices

    DEFF Research Database (Denmark)

    Smith, Anders; Bahl, Christian; Bjørk, Rasmus

    2012-01-01

    Magnetocaloric materials with a Curie temperature near room temperature have attracted signifi cant interest for some time due to their possible application for high-effi ciency refrigeration devices. This review focuses on a number of key issues of relevance for the characterization, performance....... The question of how to evaluate the suitability of a given material for use in a magnetocaloric device is covered in some detail, including a critical assessment of a number of common performance metrics. Of particular interest is which non-magnetocaloric properties need to be considered in this connection....... An overview of several important materials classes is given before considering the performance of materials in actual devices. Finally, an outlook on further developments is presented....

  14. Risk factors for blood transfusion in patients undergoing high-order Cesarean delivery.

    Science.gov (United States)

    Spiegelman, Jessica; Mourad, Mirella; Melka, Stephanie; Gupta, Simi; Lam-Rachlin, Jennifer; Rebarber, Andrei; Saltzman, Daniel H; Fox, Nathan S

    2017-11-01

    The objective was to identify risk factors associated with blood transfusion in patients undergoing high-order Cesarean delivery (CD). This was a retrospective cohort study of patients undergoing third or more CD by a single maternal-fetal medicine practice between 2005 and 2016. We compared risk factors between women who did and did not receive a red blood cell transfusion during the operation or before discharge. Repeat analysis was performed after excluding women with placenta previa. A total of 514 patients were included, 18 of whom (3.5%; 95% confidence interval [CI], 2.2%-5.5%) received a blood transfusion. Placenta previa was the most significant risk factor for transfusion (61.1% of patients who received a transfusion vs. 1% of patients who did not; p blood transfusion. After women who had placenta previa were excluded, the incidence of blood transfusion was seven of 498 (1.4%; 95% CI, 0.7%-2.9%). Risk factors significantly associated with blood transfusion in the absence of previa were prophylactic anticoagulation during pregnancy and having labored. The incidence of transfusion in patients with no placenta previa, no anticoagulation, and no labor was 0.7% (95% CI, 0.3%-2.1%). Placenta previa was the most predictive risk factor for transfusion with a positive predictive value of 68.8% and a negative predictive value of 98.4%. In patients undergoing a third or more CD, only placenta previa, prophylactic anticoagulation during pregnancy, and having labored are independently associated with requiring a blood transfusion. These data can be used to guide physician ordering of prepared blood products preoperatively. © 2017 AABB.

  15. 76 FR 48169 - Advancing Regulatory Science for Highly Multiplexed Microbiology/Medical Countermeasure Devices...

    Science.gov (United States)

    2011-08-08

    ... microbiology/MCM device, their clinical application and public health/clinical needs and quality criteria for... topics: 1. Clinical Application of Highly Multiplexed Microbiology Devices: Their clinical application... to evaluate the analytical and clinical performance of highly multiplexed microbiology devices...

  16. Development of a Very High Cycle Fatigue (VHCF multiaxial testing device

    Directory of Open Access Journals (Sweden)

    M. Vieira

    2016-07-01

    Full Text Available The very high cycle region of the S-N fatigue curve has been the subject of intensive research on the last years, with special focus on axial, bending, torsional and fretting fatigue tests. Very high cycle fatigue can be achieved using ultrasonic exciters which allow for frequency testing of up to 30 kHz. Still, the multiaxial fatigue analysis is not yet developed for this type of fatigue analyses, mainly due to conceptual limitations of these testing devices. In this paper, a device designed to produce biaxial fatigue testing using a single piezoelectric axial exciter is presented, as well as the preliminary testing of this device. The device is comprised of a horn and a specimen, which are both attached to the piezoelectric exciter. The steps taken towards the final geometry of the device are presented. Preliminary experimental testing of the developed device is made using thermographic imaging, strain measurements and vibration speeds and indicates good behaviour of the tested specimen.

  17. Evaluation of a new device for sterilizing dental high-speed handpieces

    DEFF Research Database (Denmark)

    Larsen, T; Andersen, H K; Fiehn, N E

    1997-01-01

    Dental high-speed turbines and handpieces can take up and expel microorganisms during operation and thus need regular sterilization. This study established a method for validating devices used to sterilize high-speed turbines and handpieces. The air and water channels and turbine chambers were...... contaminated with suspensions of Streptococcus salivarius or endospores of Bacillus stearothermophilus. The effect of flushing and/or autoclaving performed by a new device combining both procedures was evaluated by counting the number of viable bacteria recovered from these devices. Further, the effect...... on clinically used handpieces was evaluated. In an initial experiment, the device partially reduced S. salivarius, and the endospores survived. In a second experiment, a 5 to 6 log reduction of S. salivarius in air and water channels was obtained. No growth was observed in clinically used high-speed handpieces...

  18. Implementasi Highly Available Website Dengan Distributed Replicated Block Device

    Directory of Open Access Journals (Sweden)

    Mulyanto Mulyanto

    2016-07-01

    Full Text Available As an important IT infrastructure, website is a system which requires high reliability and availability levels. Website meets the criteria as a highly available system because website must provide services to clients in real time, handle a large amount of data, and not lose data during transaction. A highly available system must meet the condition of being able to run continuously as well as guaranteeing consistency on data requests. This study designed a website with high availability. The approach was building network cluster with failover and replicated block device functions. Failover was built to provide service availability, while replicated block device provides data consistency during failure of service.  With failover cluster and replicated block device approaches, a cluster which is able to handle service failures of web server and database server on the website. The result of this study was the services of the website could run well if there was any failure in node members of the cluster. The system was able to provide 99,999 (five nines availability on database server services and 99,98  (three nines on web server services.

  19. Electric devices used in radioactive handling enclosures of the high activity laboratory

    International Nuclear Information System (INIS)

    Gaigeot, F.; Laurent, H.

    1958-08-01

    This report describes several electric, electronic and electromechanical assemblies which are used in radioactive handling enclosures. The authors propose an overview of existing or foreseen devices: a device to lift covers, a brightness comparator, a high voltage device to perform electrophoresis, a level sensor or regulator device, a regulation device to control under-pressure in an enclosure [fr

  20. Cermet insert high voltage holdoff for ceramic/metal vacuum devices

    Science.gov (United States)

    Ierna, William F.

    1987-01-01

    An improved metal-to-ceramic seal is provided wherein the ceramic body of the seal contains an integral region of cermet material in electrical contact with the metallic member, e.g., an electrode, of the seal. The seal is useful in high voltage vacuum devices, e.g., vacuum switches, and increases the high-voltage holdoff capabilities of such devices. A method of fabricating such seals is also provided.

  1. Determining the mode of high voltage breakdowns in vacuum devices

    International Nuclear Information System (INIS)

    Miller, H.C.; Furno, E.J.; Sturtz, J.P.

    1980-01-01

    High voltage breakdowns (HVBs) occur in many vacuum devices. It frequently is of great practical interest to know the type (or mode) of such HVB's, since this can indicate weak points in the device. Post-mortems can sometimes be helpful, but it would be quite desirable to have a technique which would allow the HVB mode to be determined in an operating device. Photography can be quite helpful, but unfortunately many devices do not permit optical access to the region of interest. However, the idea of using photography in conjunction with other diagnostic techniques to establish the validity of these techniques seemed promising, since these techniques could then be used to determine the mode of HVBs in opaque devices. A literature search indicates that promising techniques are to measure the voltage applied to the device (or the current through the device) and also to look for x-rays generated by the device during an HVB

  2. Progress of OLED devices with high efficiency at high luminance

    Science.gov (United States)

    Nguyen, Carmen; Ingram, Grayson; Lu, Zhenghong

    2014-03-01

    Organic light emitting diodes (OLEDs) have progressed significantly over the last two decades. For years, OLEDs have been promoted as the next generation technology for flat panel displays and solid-state lighting due to their potential for high energy efficiency and dynamic range of colors. Although high efficiency can readily be obtained at low brightness levels, a significant decline at high brightness is commonly observed. In this report, we will review various strategies for achieving highly efficient phosphorescent OLED devices at high luminance. Specifically, we will provide details regarding the performance and general working principles behind each strategy. We will conclude by looking at how some of these strategies can be combined to produce high efficiency white OLEDs at high brightness.

  3. The Angio-Seal™ femoral closure device allows immediate ambulation after coronary angiography and percutaneous coronary intervention

    DEFF Research Database (Denmark)

    Hvelplund, Anders; Jeger, Raban; Osterwalder, Remo

    2011-01-01

    To test the safety of immediate mobilisation of patients undergoing coronary angiography and percutaneous coronary intervention (PCI) closed with Angio-Seal™ -a femoral vascular closure device.......To test the safety of immediate mobilisation of patients undergoing coronary angiography and percutaneous coronary intervention (PCI) closed with Angio-Seal™ -a femoral vascular closure device....

  4. Initial experience with the Cardiva Boomerang vascular closure device in diagnostic catheterization.

    Science.gov (United States)

    Doyle, Brendan J; Godfrey, Michael J; Lennon, Ryan J; Ryan, James L; Bresnahan, John F; Rihal, Charanjit S; Ting, Henry H

    2007-02-01

    The authors studied the safety and efficacy of the Cardiva Boomerang vascular closure device in patients undergoing diagnostic cardiac catheterization. Conventional vascular closure devices (sutures, collagen plugs, or metal clips) have been associated with catastrophic complications including arterial occlusion and foreign body infections; furthermore, they cannot be utilized in patients with peripheral vascular disease or vascular access site in a vessel other than the common femoral artery. The Cardiva Boomerang device facilitates vascular hemostasis without leaving any foreign body behind at the access site, can be used in peripheral vascular disease, and can be used in vessels other than the common femoral artery A total of 96 patients undergoing transfemoral diagnostic cardiac catheterization were included in this study, including 25 (26%) patients with contraindications to conventional closure devices. Femoral angiography was performed prior to deployment of the Cardiva Boomerang closure device. Patients were ambulated at 1 hr after hemostasis was achieved. The device was successfully deployed and hemostasis achieved with the device alone in 95 (99%) patients. The device failed to deploy in 1 (1%) patient and required conversion to standard manual compression. Minor complications were observed in 5 (5%) patients. No patients experienced major complications including femoral hematoma > 4 cm, red blood cell transfusion, retroperitoneal bleed, arteriovenous fistula, pseudoaneurysm, infection, arterial occlusion, or vascular surgery. The Cardiva Boomerang device is safe and effective in patients undergoing diagnostic cardiac catheterization using the transfemoral approach, facilitating early ambulation with low rates of vascular complications. (c) 2006 Wiley-Liss, Inc.

  5. Highly air stable passivation of graphene based field effect devices.

    Science.gov (United States)

    Sagade, Abhay A; Neumaier, Daniel; Schall, Daniel; Otto, Martin; Pesquera, Amaia; Centeno, Alba; Elorza, Amaia Zurutuza; Kurz, Heinrich

    2015-02-28

    The sensitivity of graphene based devices to surface adsorbates and charge traps at the graphene/dielectric interface requires proper device passivation in order to operate them reproducibly under ambient conditions. Here we report on the use of atomic layer deposited aluminum oxide as passivation layer on graphene field effect devices (GFETs). We show that successful passivation produce hysteresis free DC characteristics, low doping level GFETs stable over weeks though operated and stored in ambient atmosphere. This is achieved by selecting proper seed layer prior to deposition of encapsulation layer. The passivated devices are also demonstrated to be robust towards the exposure to chemicals and heat treatments, typically used during device fabrication. Additionally, the passivation of high stability and reproducible characteristics is also shown for functional devices like integrated graphene based inverters.

  6. Self-aligned photolithography for the fabrication of fully transparent high-voltage devices

    Science.gov (United States)

    Zhang, Yonghui; Mei, Zengxia; Huo, Wenxing; Wang, Tao; Liang, Huili; Du, Xiaolong

    2018-05-01

    High-voltage devices, working in the range of hundreds of volts, are indispensable elements in the driving or readout circuits for various kinds of displays, integrated microelectromechanical systems and x-ray imaging sensors. However, the device performances are found hardly uniform or repeatable due to the misalignment issue, which are extremely common for offset drain high-voltage devices. To resolve this issue, this article reports a set of self-aligned photolithography technology for the fabrication of high-voltage devices. High-performance fully-transparent high-voltage thin film transistors, diodes and logic inverters are successfully fabricated with this technology. Unlike other self-aligned routes, opaque masks are introduced on the backside of the transparent substrate to facilitate proximity exposure method. The photolithography process is simulated and analyzed with technology computer aided design simulation to explain the working principle of the proximity exposure method. The substrate thickness is found to be vital for the implementation of this technology based on both simulation and experimental results. The electrical performance of high-voltage devices is dependent on the offset length, which can be delicately modulated by changing the exposure dose. The presented self-aligned photolithography technology is proved to be feasible in high-voltage circuits, demonstrating its huge potential in practical industrial applications.

  7. Comparison of the WarmCloud and Bair Hugger Warming Devices for the Prevention of Intraoperative Hypothermia in Patients Undergoing Orthotopic Liver Transplantation: A Randomized Clinical Trial

    Science.gov (United States)

    Pearce, Brett; Mattheyse, Linda; Ellard, Louise; Desmond, Fiona; Pillai, Param; Weinberg, Laurence

    2018-01-01

    Background The avoidance of hypothermia is vital during prolonged and open surgery to improve patient outcomes. Hypothermia is particularly common during orthotopic liver transplantation (OLT) and associated with undesirable physiological effects that can adversely impact on perioperative morbidity. The KanMed WarmCloud (Bromma, Sweden) is a revolutionary, closed-loop, warm-air heating mattress developed to maintain normothermia and prevent pressure sores during major surgery. The clinical effectiveness of the WarmCloud device during OLT is unknown. Therefore, we conducted a randomized controlled trial to determine whether the WarmCloud device reduces hypothermia and prevents pressure injuries compared with the Bair Hugger underbody warming device. Methods Patients were randomly allocated to receive either the WarmCloud or Bair Hugger warming device. Both groups also received other routine standardized multimodal thermoregulatory strategies. Temperatures were recorded by nasopharyngeal temperature probe at set time points during surgery. The primary endpoint was nasopharyngeal temperature recorded 5 minutes before reperfusion. Secondary endpoints included changes in temperature over the predefined intraoperative time points, number of patients whose nadir temperature was below 35.5°C and the development of pressure injuries during surgery. Results Twenty-six patients were recruited with 13 patients randomized to each group. One patient from the WarmCloud group was excluded because of a protocol violation. Baseline characteristics were similar. The mean (standard deviation) temperature before reperfusion was 36.0°C (0.7) in the WarmCloud group versus 36.3°C (0.6) in the Bairhugger group (P = 0.25). There were no statistical differences between the groups for any of the secondary endpoints. Conclusions When combined with standardized multimodal thermoregulatory strategies, the WarmCloud device does not reduce hypothermia compared with the Bair Hugger device in

  8. High-performance spinning device for DVD-based micromechanical signal transduction

    DEFF Research Database (Denmark)

    Hwu, En-Te; Chen, Ching-Hsiu; Bosco, Filippo

    2013-01-01

    Here we report a high-throughput spinning device for nanometric scale measurements of microstructures with instrumentation details and experimental results. The readout technology implemented in the designed disc-like device is based on a DVD data storage optical pick-up unit (OPU). With a spinning...

  9. High-temperature superconducting passive microwave devices, filters and antennas

    International Nuclear Information System (INIS)

    Ohshima, S.

    2000-01-01

    High-temperature superconducting (HTS) passive microwave devices, such as filters and antennas, are promising devices. In particular, HTS filters may be successfully marketed in the near future. Cross-coupled filters, ring filters, and coplanar waveguide filters are good options to reduce filter size. On the other hand, HTS patch antennas which can be cooled by a cryo-cooler are also promising devices as well, since they show higher efficiency than normal antennas. This paper examines the design process and filter properties of HTS filters as well as the gains, directivity, and cooling system of HTS patch antennas. (author)

  10. Note: Motor-piezoelectricity coupling driven high temperature fatigue device.

    Science.gov (United States)

    Ma, Z C; Du, X J; Zhao, H W; Ma, X X; Jiang, D Y; Liu, Y; Ren, L Q

    2018-01-01

    The design and performance evaluation of a novel high temperature fatigue device simultaneously driven by servo motor and piezoelectric actuator is our focus. The device integrates monotonic and cyclic loading functions with a maximum tensile load of 1800 N, driving frequency of 50 Hz, alternating load of 95 N, and maximum service temperature of 1200 °C. Multimodal fatigue tests with arbitrary combinations of static and dynamic loads are achieved. At temperatures that range from RT to 1100 °C, the tensile and tensile-fatigue coupling mechanical behaviors of UM Co50 alloys are investigated to verify the feasibility of the device.

  11. Highly Flexible and Efficient Solar Steam Generation Device.

    Science.gov (United States)

    Chen, Chaoji; Li, Yiju; Song, Jianwei; Yang, Zhi; Kuang, Yudi; Hitz, Emily; Jia, Chao; Gong, Amy; Jiang, Feng; Zhu, J Y; Yang, Bao; Xie, Jia; Hu, Liangbing

    2017-08-01

    Solar steam generation with subsequent steam recondensation has been regarded as one of the most promising techniques to utilize the abundant solar energy and sea water or other unpurified water through water purification, desalination, and distillation. Although tremendous efforts have been dedicated to developing high-efficiency solar steam generation devices, challenges remain in terms of the relatively low efficiency, complicated fabrications, high cost, and inability to scale up. Here, inspired by the water transpiration behavior of trees, the use of carbon nanotube (CNT)-modified flexible wood membrane (F-Wood/CNTs) is demonstrated as a flexible, portable, recyclable, and efficient solar steam generation device for low-cost and scalable solar steam generation applications. Benefitting from the unique structural merits of the F-Wood/CNTs membrane-a black CNT-coated hair-like surface with excellent light absorbability, wood matrix with low thermal conductivity, hierarchical micro- and nanochannels for water pumping and escaping, solar steam generation device based on the F-Wood/CNTs membrane demonstrates a high efficiency of 81% at 10 kW cm -2 , representing one of the highest values ever-reported. The nature-inspired design concept in this study is straightforward and easily scalable, representing one of the most promising solutions for renewable and portable solar energy generation and other related phase-change applications. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  12. Experimental evaluation of cooling efficiency of the high performance cooling device

    Science.gov (United States)

    Nemec, Patrik; Malcho, Milan

    2016-06-01

    This work deal with experimental evaluation of cooling efficiency of cooling device capable transfer high heat fluxes from electric elements to the surrounding. The work contain description of cooling device, working principle of cooling device, construction of cooling device. Experimental part describe the measuring method of device cooling efficiency evaluation. The work results are presented in graphic visualization of temperature dependence of the contact area surface between cooling device evaporator and electronic components on the loaded heat of electronic components in range from 250 to 740 W and temperature dependence of the loop thermosiphon condenser surface on the loaded heat of electronic components in range from 250 to 740 W.

  13. Experimental evaluation of cooling efficiency of the high performance cooling device

    Energy Technology Data Exchange (ETDEWEB)

    Nemec, Patrik, E-mail: patrik.nemec@fstroj.uniza.sk; Malcho, Milan, E-mail: milan.malcho@fstroj.uniza.sk [University of Žilina, Faculty of Mechanical Engineering, Department of Power Engineering, Univerzitna 1, 010 26 Žilina (Slovakia)

    2016-06-30

    This work deal with experimental evaluation of cooling efficiency of cooling device capable transfer high heat fluxes from electric elements to the surrounding. The work contain description of cooling device, working principle of cooling device, construction of cooling device. Experimental part describe the measuring method of device cooling efficiency evaluation. The work results are presented in graphic visualization of temperature dependence of the contact area surface between cooling device evaporator and electronic components on the loaded heat of electronic components in range from 250 to 740 W and temperature dependence of the loop thermosiphon condenser surface on the loaded heat of electronic components in range from 250 to 740 W.

  14. Flexible semi-transparent silicon (100) fabric with high-k/metal gate devices

    KAUST Repository

    Rojas, Jhonathan Prieto

    2013-01-07

    Can we build a flexible and transparent truly high performance computer? High-k/metal gate stack based metal-oxide-semiconductor capacitor devices are monolithically fabricated on industry\\'s most widely used low-cost bulk single-crystalline silicon (100) wafers and then released as continuous, mechanically flexible, optically semi-transparent and high thermal budget compatible silicon fabric with devices. This is the first ever demonstration with this set of materials which allows full degree of freedom to fabricate nanoelectronics devices using state-of-the-art CMOS compatible processes and then to utilize them in an unprecedented way for wide deployment over nearly any kind of shape and architecture surfaces. Electrical characterization shows uncompromising performance of post release devices. Mechanical characterization shows extra-ordinary flexibility (minimum bending radius of 1 cm) making this generic process attractive to extend the horizon of flexible electronics for truly high performance computers. Schematic and photograph of flexible high-k/metal gate MOSCAPs showing high flexibility and C-V plot showing uncompromised performance. Copyright © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  15. Erectile Dysfunction Among HIV Patients Undergoing Highly Active Antiretroviral Therapy: Dyslipidemia as a Main Risk Factor

    Directory of Open Access Journals (Sweden)

    Gustavo Romero‐Velez, MD

    2014-04-01

    Conclusions: ED is highly prevalent in HIV patients. Dyslipidemia should be considered as a risk factor for ED in HIV patients. Romero‐Velez G, Lisker‐Cervantes A, Villeda‐Sandoval CI, Sotomayor de Zavaleta M, Olvera‐Posada D, Sierra‐Madero JG, Arreguin‐Camacho LO, and Castillejos‐Molina RA. Erectile dysfunction among HIV patients undergoing highly active antiretroviral therapy: Dyslipidemia as a main risk factor. Sex Med 2014;2:24–30.

  16. [Definitive contraception with Essure device: Single institutional experience on 517 procedures].

    Science.gov (United States)

    Aparicio-Rodríguez-Miñón, Pablo; de la Fuente-Valero, Jesús; Martínez-Laral, Ana; Alonso-García, Ana; Sobrino-Mota, Verónica; Zapardiel-Gutiérrez, Ignacio; Hernández-Aguado, Juan J

    2015-01-01

    To analyse the outcomes of patients undergoing Essure sterilization in a single institution, interns of complications and technique failure. Retrospective descriptive study of 517 patients underwent definitive contraception with Essure device in outpatient hysteroscopy office without anesthesia and controlled at 3 months with abdominal radiography, ultrasonography and hysterosalpingography in selected cases. The success rates of the insertion of Essure was 96.8%, similar to data reported in the literature with 3.7% of vagal reactions, as most prevalent complication. 7 (1.35%) unintended pregnancies were observed. Essure is a permanent birth control device, with high rate of successful insertion and a low rate of complications. Unintended pregnancies in our study are high and we must change the protocols of placement and monitoring, considering hysterosalpingography as a routine control test.

  17. Transmission line pulse system for avalanche characterization of high power semiconductor devices

    Science.gov (United States)

    Riccio, Michele; Ascione, Giovanni; De Falco, Giuseppe; Maresca, Luca; De Laurentis, Martina; Irace, Andrea; Breglio, Giovanni

    2013-05-01

    Because of the increasing in power density of electronic devices for medium and high power application, reliabilty of these devices is of great interest. Understanding the avalanche behaviour of a power device has become very important in these last years because it gives an indication of the maximum energy ratings which can be seen as an index of the device ruggedness. A good description of this behaviour is given by the static IV blocking characteristc. In order to avoid self heating, very relevant in high power devices, very short pulses of current have to be used, whose value can change from few milliamps up to tens of amps. The most used method to generate short pulses is the TLP (Transmission Line Pulse) test, which is based on charging the equivalent capacitance of a transmission line to high value of voltage and subsequently discharging it onto a load. This circuit let to obtain very short square pulses but it is mostly used for evaluate the ESD capability of semiconductor and, in this environment, it generates pulses of low amplitude which are not high enough to characterize the avalanche behaviour of high power devices . Advanced TLP circuit able to generate high current are usually very expensive and often suffer of distorption of the output pulse. In this article is proposed a simple, low cost circuit, based on a boosted-TLP configuration, which is capable to produce very square pulses of about one hundreds of nanosecond with amplitude up to some tens of amps. A prototype is implemented which can produce pulses up to 20A of amplitude with 200 ns of duration which can characterize power devices up to 1600V of breakdown voltage. Usage of microcontroller based logic make the circuit very flexible. Results of SPICE simulation are provided, together with experimental results. To prove the effectiveness of the circuit, the I-V blocking characteristics of two commercial devices, namely a 600V PowerMOS and a 1200V Trench-IGBT, are measured at different

  18. Progress in high-efficient solution process organic photovoltaic devices fundamentals, materials, devices and fabrication

    CERN Document Server

    Li, Gang

    2015-01-01

    This book presents an important technique to process organic photovoltaic devices. The basics, materials aspects and manufacturing of photovoltaic devices with solution processing are explained. Solution processable organic solar cells - polymer or solution processable small molecules - have the potential to significantly reduce the costs for solar electricity and energy payback time due to the low material costs for the cells, low cost and fast fabrication processes (ambient, roll-to-roll), high material utilization etc. In addition, organic photovoltaics (OPV) also provides attractive properties like flexibility, colorful displays and transparency which could open new market opportunities. The material and device innovations lead to improved efficiency by 8% for organic photovoltaic solar cells, compared to 4% in 2005. Both academic and industry research have significant interest in the development of this technology. This book gives an overview of the booming technology, focusing on the solution process fo...

  19. Optimisation of a novel trailing edge concept for a high lift device

    CSIR Research Space (South Africa)

    Botha, JDM

    2015-01-01

    Full Text Available This study aimed to observe the effect of a novel concept (referred to as the flap extension) implemented on the leading edge of the flap of a three element high lift device. The high lift device, consisting of a flap, main element and slat...

  20. Penetration testing using mobile devices

    CSIR Research Space (South Africa)

    Shelembe, S

    2012-10-01

    Full Text Available et.al, 2006) ? An attempt to compromise the security of the mechanism undergoing the test, it can be host or network based (Fiocca, 2009) Difference: pen-testing and hacking is permission Its purpose is to find system vulnerabilities ? CSIR 2012... is not enough, cell-phones can hack too ? Pocket sized device is more convenient, since it is easy to carry around at anytime ? A power plug is not innocent, need to look for activity other than just traditional PCs / devices ? CSIR 2012 Slide 6 Mobile...

  1. Compact and high-efficiency device for Raman scattering measurement using optical fibers.

    Science.gov (United States)

    Mitsui, Tadashi

    2014-11-01

    We describe the design and development of a high-efficiency optical measurement device for operation within the small bore of a high-power magnet at low temperature. For the high-efficiency measurement of light emitted from this small region, we designed a compact confocal optics with lens focusing and tilting systems, and used a piezodriven translation stage that allows micron-scale focus control of the sample position. We designed a measurement device that uses 10 m-long optical fibers in order to avoid the influence of mechanical vibration and magnetic field leakage of high-power magnets, and we also describe a technique for minimizing the fluorescence signal of optical fibers. The operation of the device was confirmed by Raman scattering measurements of monolayer graphene on quartz glass with a high signal-to-noise ratio.

  2. Endoscopic Devices for Obesity.

    Science.gov (United States)

    Sampath, Kartik; Dinani, Amreen M; Rothstein, Richard I

    2016-06-01

    The obesity epidemic, recognized by the World Health Organization in 1997, refers to the rising incidence of obesity worldwide. Lifestyle modification and pharmacotherapy are often ineffective long-term solutions; bariatric surgery remains the gold standard for long-term obesity weight loss. Despite the reported benefits, it has been estimated that only 1% of obese patients will undergo surgery. Endoscopic treatment for obesity represents a potential cost-effective, accessible, minimally invasive procedure that can function as a bridge or alternative intervention to bariatric surgery. We review the current endoscopic bariatric devices including space occupying devices, endoscopic gastroplasty, aspiration technology, post-bariatric surgery endoscopic revision, and obesity-related NOTES procedures. Given the diverse devices already FDA approved and in development, we discuss the future directions of endoscopic therapies for obesity.

  3. A nanosecond high voltage pulse device for accelerator time analytical system

    International Nuclear Information System (INIS)

    Lou Binqiao; Ding Furong; Xue Zhihua; Wang Xuemei; Shen Dingyu

    2002-01-01

    A nanosecond high voltage pulse device has been designed. The pulse rise time is 10 ns. The pulse voltage reached 16000 V. This device has been used to accelerator time analytical system, its resolution time is less than 0.8%

  4. Cermet insert high voltage holdoff improvement for ceramic/metal vacuum devices

    Science.gov (United States)

    Ierna, W.F.

    1986-03-11

    An improved metal-to-ceramic seal is provided wherein the ceramic body of the seal contains an integral region of cermet material in electrical contact with the metallic member, e.g., an electrode, of the seal. The seal is useful in high voltage vacuum devices, e.g., vacuum switches, and increases the high-voltage holdoff capabilities of such devices. A method of fabricating such seals is also provided.

  5. Measurement and correlation of high frequency behaviors of a very flexible beam undergoing large deformation

    International Nuclear Information System (INIS)

    Lee, Jae Wook; Kim, Hyun Woo; Ku, Hi Chun; Yoo, Wan Suk

    2009-01-01

    A correlation method of high frequency behaviors of a very flexible beam undergoing large displacement is presented. The suggested method based on the experimental modal analysis leads to more accurate correlation results because it directly uses the modal parameters of each mode achieved from experiment. First, the modal testing and the parameter identification method are suggested for flexible multibody dynamics. Due to the flexibility of a very thin beam, traditional testing methods such as impact hammer or contact type accelerometer are not working well. The suggested measurement with high speed camera, even though the test beam is very flexible, is working well. Using measurements with a high speed camera, modal properties until the 5th mode are measured. And After measuring each damping ratio until the 5th mode, a generic damping model is constructed using inverse modal transformation technique. It's very interesting that the modal transformation technique can be also applied even in the ANCF simulation which uses the global displacement and finite slope as the nodal coordinates. The results of experiment and simulation are compared until the 5th mode frequency, respectively, by using ANCF forced vibration analysis. Through comparison between numerical simulation and experiment, this study showed that the proposed generic damping matrix, modal testing and parameter identification method is very proper in flexible multibody dynamic problems undergoing large deformation

  6. Scalp cooling successfully prevents alopecia in breast cancer patients undergoing anthracycline/taxane-based chemotherapy.

    Science.gov (United States)

    Vasconcelos, Ines; Wiesske, Alexandra; Schoenegg, Winfried

    2018-04-13

    Chemotherapy for breast cancer induces alopecia, representing a major source of patient distress. This study assesses whether a scalp-cooling device is effective in reducing chemotherapy-induced alopecia, and assesses adverse treatment effects. A prospective observational study including women with breast cancer undergoing chemotherapy and scalp cooling using a Paxman device. The primary efficacy end points were: successful hair preservation (no hair loss; <30% hair loss not requiring a wig; or <50% hair loss not requiring a wig) at the completion of chemotherapy. Secondary end points included adverse effects such as headache, pain, nausea or dizziness. The study enrolled 131 participants. Mean patient age was 49.8 years; 74% received anthracycline/taxane-based chemotherapy and 26% received taxane-monotherapy based chemotherapy. Hair preservation was successful in 102 women who underwent scalp cooling (71.0%; 95% CI = 63-79%). Only adverse events related to device use were collected, representing 7% (95% CI = 3-11%) of cases. Scalp cooling is effective in preventing hair loss among breast cancer patients undergoing standard chemotherapy treatment, and has minimal adverse effects. Copyright © 2018. Published by Elsevier Ltd.

  7. High speed serdes devices and applications

    CERN Document Server

    Stauffer, David R; Sorna, Michael A; Dramstad, Kent; Ogilvie, Clarence Rosser; Amanullah, Mohammad; Rockrohr, James Donald

    2008-01-01

    Offers an understanding of the features and functions typically found on HSS devices. This book explains how these HSS devices are used in protocol applications and the analysis which must be performed to use such HSS devices.

  8. Flexible Gallium Nitride for High-Performance, Strainable Radio-Frequency Devices.

    Science.gov (United States)

    Glavin, Nicholas R; Chabak, Kelson D; Heller, Eric R; Moore, Elizabeth A; Prusnick, Timothy A; Maruyama, Benji; Walker, Dennis E; Dorsey, Donald L; Paduano, Qing; Snure, Michael

    2017-12-01

    Flexible gallium nitride (GaN) thin films can enable future strainable and conformal devices for transmission of radio-frequency (RF) signals over large distances for more efficient wireless communication. For the first time, strainable high-frequency RF GaN devices are demonstrated, whose exceptional performance is enabled by epitaxial growth on 2D boron nitride for chemical-free transfer to a soft, flexible substrate. The AlGaN/GaN heterostructures transferred to flexible substrates are uniaxially strained up to 0.85% and reveal near state-of-the-art values for electrical performance, with electron mobility exceeding 2000 cm 2 V -1 s -1 and sheet carrier density above 1.07 × 10 13 cm -2 . The influence of strain on the RF performance of flexible GaN high-electron-mobility transistor (HEMT) devices is evaluated, demonstrating cutoff frequencies and maximum oscillation frequencies greater than 42 and 74 GHz, respectively, at up to 0.43% strain, representing a significant advancement toward conformal, highly integrated electronic materials for RF applications. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  9. Estimation of Body Composition Depends on Applied Device in Patients Undergoing Major Abdominal Surgery

    NARCIS (Netherlands)

    Haverkort, E.B.; Binnekade, J.M.; van Bokhorst-de van der Schueren, M.A.E.; Gouma, D.J.; de Haan, R.J.

    2015-01-01

    Background: Bioelectrical impedance analysis (BIA) is a method used to estimate body compartments such as fat-free mass (FFM) and fat mass (FM). Two BIA devices, a single-frequency BIA (SF-BIA) device and a bioimpedance spectroscopy (BIS) approach, were compared to evaluate their reliability and to

  10. Estimation of body composition depends on applied device in patients undergoing major abdominal surgery

    NARCIS (Netherlands)

    Haverkort, Elizabeth B.; Binnekade, Jan M.; de van der Schueren, Marian A. E.; Gouma, Dirk J.; de Haan, Rob J.

    2015-01-01

    Bioelectrical impedance analysis (BIA) is a method used to estimate body compartments such as fat-free mass (FFM) and fat mass (FM). Two BIA devices, a single-frequency BIA (SF-BIA) device and a bioimpedance spectroscopy (BIS) approach, were compared to evaluate their reliability and to study

  11. Comparative study of low and high aspect ratio devices for ITER design options

    International Nuclear Information System (INIS)

    Sugihara, Masayoshi; Tada, Eisuke; Shimomura, Yasuo; Tsunematsu, Toshihide; Nishio, Satoshi; Nakazato, Toshiko; Murakami, Yoshiki; Koizumi, Koichi

    1992-09-01

    Comparative study on the plasma performance and the engineering characteristics of low and high aspect ratio devices for ITER (International Thermonuclear Experimental Reactor) design option is done to examine quantitatively the expected merit and demerit of high aspect ratio device on steady state operation. Device parameters of aspect ratio A=3 and 4 are chosen based on ITER-power scaling law. Improvement of steady state operation with A=4 is found only moderate. Reduction of stability margin in vertical instability is about 20% and plasma elongation must be decreased from 2 down to about 1.8 to recover this reduction of stability margin with A=4. If such lower elongation is employed, single null divertor configuration should be employed to reduce the capacity of poloidal field system. Detailed 2D divertor code calculation shows that peak heat load per unit area of A=4 device with SN configuration increases compared with A=3 device with DN configuration, contrary to the predictions so far made. Preliminary engineering studies indicate that A=4 device would have less space for handling the in-vessel components and doubled toroidal field magnet weight and winding length, and hence is less desirable when compared with the present ITER design (A=3). Based on these examinations, it is concluded that high aspect ratio device does not have remarkable advantage than low aspect ratio device, and the latter device has similar capability for the prospect of future commercial reactor to the former device. (J.P.N.)

  12. 76 FR 71982 - Advancing Regulatory Science for Highly Multiplexed Microbiology/Medical Countermeasure Devices...

    Science.gov (United States)

    2011-11-21

    ... Multiplexed Microbiology Devices: Their clinical application and public health/clinical needs; inclusion of...] Advancing Regulatory Science for Highly Multiplexed Microbiology/ Medical Countermeasure Devices; Public... Multiplexed Microbiology/ Medical Countermeasure Devices'' that published in the Federal Register of August 8...

  13. High voltage MOSFET devices and methods of making the devices

    Science.gov (United States)

    Banerjee, Sujit; Matocha, Kevin; Chatty, Kiran

    2018-06-05

    A SiC MOSFET device having low specific on resistance is described. The device has N+, P-well and JFET regions extended in one direction (Y-direction) and P+ and source contacts extended in an orthogonal direction (X-direction). The polysilicon gate of the device covers the JFET region and is terminated over the P-well region to minimize electric field at the polysilicon gate edge. In use, current flows vertically from the drain contact at the bottom of the structure into the JFET region and then laterally in the X direction through the accumulation region and through the MOSFET channels into the adjacent N+ region. The current flowing out of the channel then flows along the N+ region in the Y-direction and is collected by the source contacts and the final metal. Methods of making the device are also described.

  14. High voltage MOSFET devices and methods of making the devices

    Science.gov (United States)

    Banerjee, Sujit; Matocha, Kevin; Chatty, Kiran

    2015-12-15

    A SiC MOSFET device having low specific on resistance is described. The device has N+, P-well and JFET regions extended in one direction (Y-direction) and P+ and source contacts extended in an orthogonal direction (X-direction). The polysilicon gate of the device covers the JFET region and is terminated over the P-well region to minimize electric field at the polysilicon gate edge. In use, current flows vertically from the drain contact at the bottom of the structure into the JFET region and then laterally in the X direction through the accumulation region and through the MOSFET channels into the adjacent N+ region. The current flowing out of the channel then flows along the N+ region in the Y-direction and is collected by the source contacts and the final metal. Methods of making the device are also described.

  15. StarClose Vascular Closure Device: Prospective Study on 222 Deployments in an Interventional Radiology Practice

    International Nuclear Information System (INIS)

    Imam, Atique; Carter, Ranjana M. S.; Phillips-Hughes, Jane; Boardman, Philip; Uberoi, Raman

    2007-01-01

    The StarClose device (Abbott Vascular Devices; Abbott Laboratories, Redwood City, CA) utilizes an externally placed Nitinol clip to achieve arterial closure following femoral artery puncture. The objectives of this study were to assess the efficacy and complications of the StarClose device in patients undergoing interventional radiological procedures. Preprocedural clotting status, pulse and blood pressure, severity of vessel calcification, sheath size, and time to deployment were recorded. Postdeployment complications immediately postprocedure, at 1 h, at 2 h, and at 1 week were recorded. A duplex scan was performed in the first 10 patients to assess any immediate vascular complications. Deployments were successful in 96% achieving immediate hemostasis. Mean deployment time was 48 s. There were no major complications. The StarClose device was found to have a high technical and clinical efficacy

  16. Improved vascularization of planar membrane diffusion devices following continuous infusion of vascular endothelial growth factor.

    Science.gov (United States)

    Trivedi, N; Steil, G M; Colton, C K; Bonner-Weir, S; Weir, G C

    2000-01-01

    Improving blood vessel formation around an immunobarrier device should improve the survival of the encapsulated tissue. In the present study we investigated the formation of new blood vessels around a planar membrane diffusion device (the Baxter Theracyte System) undergoing a continuous infusion of vascular endothelial growth factor through the membranes and into the surrounding tissue. Each device (20 microl) had both an inner immunoisolation membrane and an outer vascularizing membrane. Human recombinant vascular endothelial growth factor-165 was infused at 100 ng/day (low dose: n = 6) and 500 ng/day (high dose: n = 7) for 10 days into devices implanted s.c. in Sprague-Dawley rats; noninfused devices transplanted for an identical period were used as controls (n = 5). Two days following the termination of VEGF infusion, devices were loaded with 20 microl of Lispro insulin (1 U/kg) and the kinetics of insulin release from the lumen of the device was assessed. Devices were then explanted and the number of blood vessels (capillary and noncapillary) was quantified using morphometry. High-dose vascular endothelial growth factor infusion resulted in two- to threefold more blood vessels around the device than that obtained with the noninfused devices and devices infused with low-dose vascular endothelial growth factor. This increase in the number of blood vessels was accompanied by a modest increase in insulin diffusion from the device in the high-dose vascular endothelial growth factor infusion group. We conclude that vascular endothelial growth factor can be used to improve blood vessel formation adjacent to planar membrane diffusion devices.

  17. Pre-market clinical evaluations of innovative high-risk medical devices in Europe.

    Science.gov (United States)

    Hulstaert, Frank; Neyt, Mattias; Vinck, Imgard; Stordeur, Sabine; Huić, Mirjana; Sauerland, Stefan; Kuijpers, Marja R; Abrishami, Payam; Vondeling, Hindrik; Flamion, Bruno; Garattini, Silvio; Pavlovic, Mira; van Brabandt, Hans

    2012-07-01

    High-quality clinical evidence is most often lacking when novel high-risk devices enter the European market. At the same time, a randomized controlled trial (RCT) is often initiated as a requirement for obtaining market access in the US. Should coverage in Europe be postponed until RCT data are available? We studied the premarket clinical evaluation of innovative high-risk medical devices in Europe compared with the US, and with medicines, where appropriate. The literature and regulatory documents were checked. Representatives from industry, Competent Authorities, Notified Bodies, Ethics Committees, and HTA agencies were consulted. We also discuss patient safety and the transparency of information. In contrast to the US, there is no requirement in Europe to demonstrate the clinical efficacy of high-risk devices in the premarket phase. Patients in Europe can thus have earlier access to a potentially lifesaving device, but at the risk of insufficiently documented efficacy and safety. Variations in the stringency of clinical reviews, both at the level of Notified Bodies and Competent Authorities, do not guarantee patient safety. We tried to document the design of premarket trials in Europe and number of patients exposed, but failed as this information is not made public. Furthermore, the Helsinki Declaration is not followed with respect to the registration and publication of premarket trials. For innovative high-risk devices, new EU legislation should require the premarket demonstration of clinical efficacy and safety, using an RCT if possible, and a transparent clinical review, preferably centralized.

  18. Long-term outcomes of children undergoing video-assisted gastrostomy

    OpenAIRE

    Sal?, Martin; Santimano, Ana; Helmroth, Sofia; Stenstr?m, Pernilla; Arnbjornsson, Einar ?lafur

    2016-01-01

    Purpose The aims of this study were to assess the short- and long-term complication rates after video-assisted gastrostomy (VAG), the effects of age and gender on long-term complications and the effect of duration of gastrostomy tube retention on the need for gastroraphy when the gastrostomy device was removed. Methods This was a retrospective study of children undergoing VAG at a single institution. Children who died or moved from the area were excluded. The rates of short- and long-term com...

  19. A pneumatic device for rapid loading of DNA sequencing gels.

    Science.gov (United States)

    Panussis, D A; Cook, M W; Rifkin, L L; Snider, J E; Strong, J T; McGrane, R M; Wilson, R K; Mardis, E R

    1998-05-01

    This work describes the design and construction of a device that facilitates the loading of DNA samples onto polyacrylamide gels for detection in the Perkin Elmer/Applied Biosystems (PE/ABI) 373 and 377 DNA sequencing instruments. The device is mounted onto the existing gel cassettes and makes the process of loading high-density gels less cumbersome while the associated time and errors are reduced. The principle of operation includes the simultaneous transfer of the entire batch of samples, in which a spring-loaded air cylinder generates positive pressure and flexible silica capillaries transfer the samples. A retractable capillary array carrier allows the delivery ends of the capillaries to be held up clear of the gel during loader attachment on the gel plates, while enabling their insertion in the gel wells once the device is securely mounted. Gel-loading devices capable of simultaneously transferring 72 samples onto the PE/ABI 373 and 377 are currently being used in our production sequencing groups while a 96-sample transfer prototype undergoes testing.

  20. A quality improvement project to reduce hypothermia in infants undergoing MRI scanning

    International Nuclear Information System (INIS)

    Dalal, Priti G.; Parekh, Uma; Dhar, Padmani; McQuillan, Patrick M.; Porath, Janelle; Mujsce, Dennis; Wang, Ming; Hulse, Michael

    2016-01-01

    Hypothermia prevention strategies during MRI scanning under general anesthesia in infants may pose a challenge due to the MRI scanner's technical constraints. Previous studies have demonstrated conflicting results related to increase or decrease in post-scan temperatures in children. We noted occurrences of post-scan hypothermia in anesthetized infants despite the use of routine passive warming techniques. The aims of our quality improvement project were (a) to identify variables associated with post-scan hypothermia in infants and (b) to develop and implement processes to reduce occurrence of hypothermia in neonatal intensive care unit (NICU) infants undergoing MRI. One hundred sixty-four infants undergoing MRI scanning were prospectively audited for post-scan body temperatures. A multidisciplinary team identified potential variables associated with post-scan hypothermia and designed preventative strategies: protocol development, risk factor identification, vigilance and use of a vacuum immobilizer. Another audit was performed, specifically focusing on NICU infants. In the initial phase, we found that younger age (P = 0.002), lower weight (P = 0.005), lower pre-scan temperature (P < 0.01), primary anesthetic technique with propofol (P < 0.01), advanced airway devices (P = 0.02) and being in the NICU (P < 0.01) were associated with higher odds for developing post-scan decrease in body temperature. Quality improvement processes decreased the occurrence of hypothermia in NICU infants undergoing MRI scanning from 65% to 18% (95% confidence interval for the difference, 26-70%, P < 0.001). Several variables, including being in the NICU, are associated with a decrease in post-scan temperature in infants undergoing MRI scanning under sedation/general anesthesia. Implementation of strategies to prevent hypothermia in infants may be challenging in the high-risk MRI environment. We were able to minimize this problem in clinical practice by applying quality improvement

  1. Proceedings of the workshop on new solid state devices for high energy physics

    International Nuclear Information System (INIS)

    1987-12-01

    This paper contains articles on semiconductor devices used in the detection of high energy particles. Some articles reported: Position sensitive semiconductor devices; Scintillation techniques and optical devices; Radiation damage to detectors; VLSI for physics; and experience with Si detectors in NA32

  2. Filter and window assemblies for high power insertion device synchrotron radiation sources

    International Nuclear Information System (INIS)

    Khounsary, A.M.; Viccaro, P.J.; Kuzay, T.M.

    1992-01-01

    The powerful beams of x-ray radiation generated by insertion devices at high power synchrotron facilities deposit substantial amounts of localized heat in the front end and optical components that they intercept. X-ray beams from undulator sources, in particular, are confined to very narrow solid angles and therefore impose very high absorbed heat fluxes. This paper is devoted to a detailed study of the design of windows for the Advanced Photon Source undulators and wigglers, emphasizing alternative design concepts, material considerations, and cooling techniques necessary for handling the high heat load of the insertion devices. Various designs are thermally and structurally analyzed by numerically simulating full-power operating conditions. This analysis also has relevance to the design and development of other beam line components which are subjected to the high heat loads of insertion devices

  3. Effect of a Scalp Cooling Device on Alopecia in Women Undergoing Chemotherapy for Breast Cancer: The SCALP Randomized Clinical Trial.

    Science.gov (United States)

    Nangia, Julie; Wang, Tao; Osborne, Cynthia; Niravath, Polly; Otte, Kristen; Papish, Steven; Holmes, Frankie; Abraham, Jame; Lacouture, Mario; Courtright, Jay; Paxman, Richard; Rude, Mari; Hilsenbeck, Susan; Osborne, C Kent; Rimawi, Mothaffar

    2017-02-14

    Chemotherapy may induce alopecia. Although scalp cooling devices have been used to prevent this alopecia, efficacy has not been assessed in a randomized clinical trial. To assess whether a scalp cooling device is effective at reducing chemotherapy-induced alopecia and to assess adverse treatment effects. Multicenter randomized clinical trial of women with breast cancer undergoing chemotherapy. Patients were enrolled from December 9, 2013, to September 30, 2016. One interim analysis was planned to allow the study to stop early for efficacy. Data reported are from the interim analysis. This study was conducted at 7 sites in the United States, and 182 women with breast cancer requiring chemotherapy were enrolled and randomized. Participants were randomized to scalp cooling (n = 119) or control (n = 63). Scalp cooling was done using a scalp cooling device. The primary efficacy end points were successful hair preservation assessed using the Common Terminology Criteria for Adverse Events version 4.0 scale (grade 0 [no hair loss] or grade 1 [Organisation for Research and Treatment of Cancer Quality of Life Questionnaire-Core 30, Hospital Anxiety and Depression Scale, and a summary scale of the Body Image Scale. At the time of the interim analysis, 142 participants were evaluable. The mean (SD) age of the patients was 52.6 (10.1) years; 36% (n = 51) received anthracycline-based chemotherapy and 64% (n = 91) received taxane-based chemotherapy. Successful hair preservation was found in 48 of 95 women with cooling (50.5%; 95% CI, 40.7%-60.4%) compared with 0 of 47 women in the control group (0%; 95% CI, 0%-7.6%) (success rate difference, 50.5%; 95% CI, 40.5%-60.6%). Because the 1-tailed P value from the Fisher exact test was women with stage I to II breast cancer receiving chemotherapy with a taxane, anthracycline, or both, those who underwent scalp cooling were significantly more likely to have less than 50% hair loss after the fourth chemotherapy cycle

  4. Electrostatic MEMS devices with high reliability

    Science.gov (United States)

    Goldsmith, Charles L; Auciello, Orlando H; Sumant, Anirudha V; Mancini, Derrick C; Gudeman, Chris; Sampath, Suresh; Carlilse, John A; Carpick, Robert W; Hwang, James

    2015-02-24

    The present invention provides for an electrostatic microelectromechanical (MEMS) device comprising a dielectric layer separating a first conductor and a second conductor. The first conductor is moveable towards the second conductor, when a voltage is applied to the MEMS device. The dielectric layer recovers from dielectric charging failure almost immediately upon removal of the voltage from the MEMS device.

  5. On-Board Thermal Management of Waste Heat from a High-Energy Device

    National Research Council Canada - National Science Library

    Klatt, Nathan D

    2008-01-01

    The use of on-board high-energy devices such as megawatt lasers and microwave emitters requires aircraft system integration of thermal devices to either get rid of waste heat or utilize it in other areas of the aircraft...

  6. Updated tokamak systems code and applications to high-field ignition devices

    International Nuclear Information System (INIS)

    Reid, R.L.; Galambos, J.D.; Peng, Y-K.M.; Strickler, D.J.; Selcow, E.C.

    1985-01-01

    This paper describes revisions made to the Tokamak Systems Code to more accurately model high-field copper ignition devices. The major areas of revision were in the plasma physics model, the toroidal field (TF) coil model, and the poloidal field (PF) coil/MHD model. Also included in this paper are results obtained from applying the revised code to a study for a high-field copper ignition device to determine the impact of magnetic field on axis, (at the major radius), on performance, and on cost

  7. Spatial and temporal instabilities in high voltage power devices

    Energy Technology Data Exchange (ETDEWEB)

    Milady, Saeed

    2010-01-29

    Dynamic avalanche can occur during the turn-off process of high voltage bipolar devices, e.g. IGBTs and p{sup +}n{sup -}n{sup +} power diodes, that may result in spatial instabilities of the homogeneous current density distribution across the device and the formation of current filaments. Filaments may cause the destruction of the device, mainly because of the high local temperatures. The first part of this work is dedicated to the current filament behavior. The positive feedback mechanisms caused by the transient current flow through the gate capacitance of an IGBT operating under short circuit conditions may result in oscillations and temporal instabilities of the IGBT current. The oscillations may cause electromagnetic interference (EMI). Furthermore, the positive feedback mechanism may accelerate the over-heating of the device and result in a thermal run-away. This is the subject of the second part of this work. In the first part of this work using the device simulation results of power diodes the underlying physical mechanisms of the filament dynamic is investigated. Simulation results of diode structures with evenly distributed doping inhomogeneities show that, the filament motion gets smoother as the distance between the inhomogeneities decreases. Hopping to faraway inhomogeneities turns into the hopping to neighboring ones and finally a smooth motion. In homogeneous structures the slow inhibitory effect of the electron-hole plasma extraction and the fast activation, due to hole current flowing along the filament, result in a smooth filament motion. An analytical model for the filament velocity under isothermal conditions is presented that can reproduce the simulation data satisfactorily. The influence of the boundary conditions on the filament behavior is discussed. The positive beveled edge termination prohibits a long stay of the filament at the edge reducing the risk of filament pinning. Self-heating effects may turn the initially electrically triggered

  8. Highly efficient tandem organic light-emitting devices employing an easily fabricated charge generation unit

    Science.gov (United States)

    Yang, Huishan; Yu, Yaoyao; Wu, Lishuang; Qu, Biao; Lin, Wenyan; Yu, Ye; Wu, Zhijun; Xie, Wenfa

    2018-02-01

    We have realized highly efficient tandem organic light-emitting devices (OLEDs) employing an easily fabricated charge generation unit (CGU) combining 1,4,5,8,9,11-hexaazatriphenylene-hexacarbonitrile with ultrathin bilayers of CsN3 and Al. The charge generation and separation processes of the CGU have been demonstrated by studying the differences in the current density-voltage characteristics of external-carrier-excluding devices. At high luminances of 1000 and 10000 cd/m2, the current efficiencies of the phosphorescent tandem device are about 2.2- and 2.3-fold those of the corresponding single-unit device, respectively. Simultaneously, an efficient tandem white OLED exhibiting high color stability and warm white emission has also been fabricated.

  9. Ultra-high Efficiency DC-DC Converter using GaN Devices

    DEFF Research Database (Denmark)

    Ramachandran, Rakesh

    2016-01-01

    properties of GaN devices can be utilized in power converters to make them more compact and highly efficient. This thesis entitled “Ultra-high Efficiency DC-DC Converter using GaN devices” focuses on achieving ultra-high conversion efficiency in an isolated dc-dc converter by the optimal utilization of Ga...... for many decades. However, the rate of improvement slowed as the silicon power materials asymptotically approached its theoretical bounds. Compared to Si, wideband gap materials such as Silicon Carbide (SiC) and Gallium Nitride (GaN) are promising semiconductors for power devices due to their superior...... in this thesis. Efficiency measurements from the hardware prototype of both the topologies are also presented in this thesis. Finally, the bidirectional operation of an optimized isolated dc-dc converter is presented. The optimized converter has achieved an ultra-high efficiency of 98.8% in both directions...

  10. Three-terminal devices of high-Tc superconductors: A status report and future challenges

    International Nuclear Information System (INIS)

    Kung, Pang-Jen; Carnegie-Mellon Univ., Pittsburgh, PA

    1992-01-01

    A study has been conducted on the recent progress of the three-terminal devices with transistor-like characteristics fabricated from the high-T c superconducting materials. This study explored the operating principles and characteristics of these devices in relation to the relevant materials and techniques. A comparison of a variety of techniques for superconducting thin film deposition will be given. This study indirates that the feasibility of fabricating hybrid devices composed of semiconductors and superconductors appear to be the key issue to push forward the applications of high-T c superconductors in microelectronics. The junction field-effect transistors with a semiconductor base controlled by the proximity effect are likely to be more manufacturable. The factors that influence the operating reliability of devices and the problems arising from integrating and packaging the devices will also be discussed

  11. Use of thromboelastography to tailor dual-antiplatelet therapy in patients undergoing treatment of intracranial aneurysms with the Pipeline embolization device.

    Science.gov (United States)

    McTaggart, Ryan A; Choudhri, Omar A; Marcellus, Mary L; Brennan, Tom; Steinberg, Gary K; Dodd, Robert L; Do, Huy M; Marks, Michael P

    2015-06-01

    Platelet function testing is controversial and not well studied in patients with neurovascular disease. To evaluate the performance of thromboelastography (TEG) as a platelet function test in neurovascular patients treated with the Pipeline embolization device (PED). A prospective protocol was instituted for platelet function testing in patients undergoing repair of intracranial aneurysms with the PED. All patients received dual antiplatelet therapy (DAT) and their response to both P2Y12 inhibitors and aspirin was quantified with TEG. Each patient's DAT induction strategy was tailored based on the percentage ADP-induced and percentage arachidonic acid-induced platelet inhibition reported by TEG. Data collected included clinical presentation, aneurysm characteristics, treatment details, and periprocedural events. Patients were followed up clinically and/or angiographically at 30 days, 6 months, and 1 year. Thirty-four PED procedures were performed on 31 patients. TEG results altered the DAT strategy in 35% of patients. Technical success with the Pipeline placement was 100%. Two patients had minor strokes and five had transient ischemic attacks (TIAs). There have been no hemorrhagic complications. No patient had permanent neurologic deficits. Six of eight (75%) of patients with thromboembolic/TIA events were ADP-induced hyporesponders by TEG. Our 6- and 12-month angiographic occlusion rates were 78.9% and 89.5%, respectively. The 19 major branches covered by the PED that were assessed by follow-up imaging have all remained patent. Platelet function testing with TEG altered our DAT induction strategy in a significant number of cases. No hemorrhagic or disabling thromboembolic complications were seen in this series. Future studies should compare methods of platelet function testing and, possibly, no platelet function testing in neurovascular patients undergoing flow diversion and/or stent-assisted treatment of intracranial aneurysms. Published by the BMJ

  12. Short-Term Safety and Efficacy of Femoral Vascular Closure after Percutaneous Coronary Intervention with Combination of the Boomerang(TM) Device and Intravenous Protamine Sulfate.

    Science.gov (United States)

    Chen, Ching-Pei; Huang, Huang-Kai; Hsia, Chien-Hsun; Chang, Yung-Ming; Lin, Lee-Shin; Lee, Cheng-Liang

    2013-11-01

    The Cardiva Boomerang(TM) is a device used to perform femoral vascular closure. It facilitates passive hemostasis at the arteriotomy site, leaving no residual foreign body. We performed a controlled, randomized study of 60 patients undergoing percutaneous coronary intervention. Patients were randomized into two groups (30 per group) to undergo vascular closure with the Boomerang(TM) or the Perclose(TM) suture-based device after the intravenous administration of protamine sulfate. We compared overall success rates, patient-reported pain, length of time to achieve hemostasis and mobilization of the patient, and the frequency of complications in the two groups. Overall success rates using the Boomerang(TM) and Perclose(TM) devices were similarly high, at 93% and 97%, respectively. The Boomerang(TM) was significantly quicker to deploy than the PercloseTM, device deployment time, median (Q1-Q3), [2.00 (1.33-2.75) vs. 3.84 (2.75-4.38) mins, p Boomerang(TM) group (1.1 ± 1.7 vs. 6.4 ± 2.9, p Boomerang(TM) (p Boomerang(TM) device is as safe and effective as the Perclose(TM) device for femoral vascular closure, but quicker to deploy and less painful to patients. Boomerang; Percutaneous intervention; Vascular closure device.

  13. A new device for the inflation of the antigravity suit.

    Science.gov (United States)

    Brodrick, P M

    1986-02-01

    The 'Schuco' orthopaedic tourniquet inflator can be simply converted into a suitable device for inflating an antigravity suit (G-suit). The antigravity suit may be used on neurosurgical patients undergoing procedures in the sitting position to help prevent hypotension and air embolism. The availability of this device may encourage the more widespread use of an antigravity suit in neuro-anaesthetic practice.

  14. Charge-coupled devices for particle detection with high spatial resolution

    International Nuclear Information System (INIS)

    Farley, F.J.; Damerell, C.J.S.; Gillman, A.R.; Wickens, F.J.

    1980-10-01

    The results of a study of the possible application of a thin microelectronic device (the charge-coupled device) to high energy physics as particle detectors with good spatial resolution which can distinguish between tracks emerging from the primary vertex and those from secondary vertices due to the decay of short lived particles with higher flavours, are reported. Performance characteristics indicating the spatial resolution, particle discrimination, time resolution, readout time and lifetime of such detectors have been obtained. (U.K.)

  15. Ion implantation in compound semiconductors for high-performance electronic devices

    International Nuclear Information System (INIS)

    Zolper, J.C.; Baca, A.G.; Sherwin, M.E.; Klem, J.F.

    1996-01-01

    Advanced electronic devices based on compound semiconductors often make use of selective area ion implantation doping or isolation. The implantation processing becomes more complex as the device dimensions are reduced and more complex material systems are employed. The authors review several applications of ion implantation to high performance junction field effect transistors (JFETs) and heterostructure field effect transistors (HFETs) that are based on compound semiconductors, including: GaAs, AlGaAs, InGaP, and AlGaSb

  16. Innovation of High Voltage Supply Adjustment Device on Diagnostic X-Ray Machine

    International Nuclear Information System (INIS)

    Sujatno; Wiranto Budi Santoso

    2010-01-01

    Innovation of high voltage supply adjustment device on diagnostic x-ray machine has been carried out. The innovation is conducted by utilizing an electronic circuit as a high voltage adjustment device. Usually a diagnostic x-ray machine utilizes a transformer or an auto-transformer as a high voltage supply adjustment device. A high power diagnostic x-ray machine needs a high power transformer which has big physical dimension. Therefore a box control where the transformer is located has to have big physical dimension. Besides, the price of the transformer is expensive and hardly found in local markets. In this innovation, the transformer is replaced by an electronic circuit. The main component of the electronic circuit is Triac BTA-40. As adjustment device, the triac is controlled by a variable resistor which is coupled by a stepper motor. A step movement of stepper motor varies a value of resistor. The resistor value determines the triac gate voltage. Furthermore the triac will open according to the value of electrical current flowing to the gate. When the gate is open, electrical voltage and current will flow from cathode to anode of the triac. The value of these electrical voltage and current depend on gate open condition. Then this triac output voltage is feed to diagnostic x-ray machine high voltage supply. Therefore the high voltage value of diagnostic x-ray machine is adjusted by the output voltage of the electronic circuit. By using this electronic circuit, the physical dimension of diagnostic x-ray machine box control and the price of the equipment can be reduced. (author)

  17. High-Tc SNS Junctions: A New Generation of Proximity-Coupled Josephson Devices

    Science.gov (United States)

    Kleinsasser, A. W.

    1997-01-01

    This paper reviews this evolution of proximity - coupled Josephson jucntion from the early investigations on low temperature superconductor-normal -superconductor junctions through the introduction of hybrid superconductor-semiconductor devices and the resulting interest in mesoscopic Josephson junctions, to the recent development of high temperature devices.

  18. Energy harvesting from high-rise buildings by a piezoelectric harvester device

    International Nuclear Information System (INIS)

    Xie, X.D.; Wang, Q.; Wang, S.J.

    2015-01-01

    A novel piezoelectric technology of harvesting energy from high-rise buildings is developed. While being used to harness vibration energy of a building, the technology is also helpful to dissipate vibration of the building by the designed piezoelectric harvester as a tuned mass damper. The piezoelectric harvester device is made of two groups of series piezoelectric generators connected by a shared shaft. The shaft is driven by a linking rod hinged on a proof mass on the tip of a cantilever fixed on the roof of the building. The influences of some practical considerations, such as the mass ratio of the proof mass to the main structure, the ratios of the length and flexural rigidity of the cantilever to those of the main structure, on the root mean square (RMS) of the generated electric power and the energy harvesting efficiency of the piezoelectric harvester device are discussed. The research provides a new method for an efficient and practical energy harvesting from high-rise buildings by piezoelectric harvesters. - Highlights: • A new piezoelectric technology in energy harvesting from high-rise buildings is introduced. • A new mathematics model to calculate the energy harvested by the piezoelectric device is developed. • A novel efficient design of the piezoelectric harvester device in provided. • An electric power up to 432 MW under a seismic excitation at a frequency of 30 rad/s is achieved.

  19. Low-cost high-quality crystalline germanium based flexible devices

    KAUST Repository

    Nassar, Joanna M.

    2014-06-16

    High performance flexible electronics promise innovative future technology for various interactive applications for the pursuit of low-cost, light-weight, and multi-functional devices. Thus, here we show a complementary metal oxide semiconductor (CMOS) compatible fabrication of flexible metal-oxide-semiconductor capacitors (MOSCAPs) with high-κ/metal gate stack, using a physical vapor deposition (PVD) cost-effective technique to obtain a high-quality Ge channel. We report outstanding bending radius ~1.25 mm and semi-transparency of 30%.

  20. Low-cost high-quality crystalline germanium based flexible devices

    KAUST Repository

    Nassar, Joanna M.; Hussain, Aftab M.; Rojas, Jhonathan Prieto; Hussain, Muhammad Mustafa

    2014-01-01

    High performance flexible electronics promise innovative future technology for various interactive applications for the pursuit of low-cost, light-weight, and multi-functional devices. Thus, here we show a complementary metal oxide semiconductor (CMOS) compatible fabrication of flexible metal-oxide-semiconductor capacitors (MOSCAPs) with high-κ/metal gate stack, using a physical vapor deposition (PVD) cost-effective technique to obtain a high-quality Ge channel. We report outstanding bending radius ~1.25 mm and semi-transparency of 30%.

  1. Fabrication and Characterization of Li-ion Electrodes for High-Power Energy Storage Devices

    OpenAIRE

    Lai, Chun-Han

    2017-01-01

    Renewable energy technologies have been a rapidly emerging option to meet future energy demand. However, their systems require stable, high-power storage devices to overcome fluctuating energy outputs for consistent distribution. Since traditional Li-ion batteries (LIB) are not considered to be capable of fast charging and discharging, we have to develop devices with new chemistry for high-power operation. This dissertation focuses on the development of supercapacitors and high-rate batteries...

  2. SU-F-T-452: Influence of Dose Calculation Algorithm and Heterogeneity Correction On Risk Categorization of Patients with Cardiac Implanted Electronic Devices Undergoing Radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Iwai, P; Lins, L Nadler [AC Camargo Cancer Center, Sao Paulo (Brazil)

    2016-06-15

    Purpose: There is a lack of studies with significant cohort data about patients using pacemaker (PM), implanted cardioverter defibrillator (ICD) or cardiac resynchronization therapy (CRT) device undergoing radiotherapy. There is no literature comparing the cumulative doses delivered to those cardiac implanted electronic devices (CIED) calculated by different algorithms neither studies comparing doses with heterogeneity correction or not. The aim of this study was to evaluate the influence of the algorithms Pencil Beam Convolution (PBC), Analytical Anisotropic Algorithm (AAA) and Acuros XB (AXB) as well as heterogeneity correction on risk categorization of patients. Methods: A retrospective analysis of 19 3DCRT or IMRT plans of 17 patients was conducted, calculating the dose delivered to CIED using three different calculation algorithms. Doses were evaluated with and without heterogeneity correction for comparison. Risk categorization of the patients was based on their CIED dependency and cumulative dose in the devices. Results: Total estimated doses at CIED calculated by AAA or AXB were higher than those calculated by PBC in 56% of the cases. In average, the doses at CIED calculated by AAA and AXB were higher than those calculated by PBC (29% and 4% higher, respectively). The maximum difference of doses calculated by each algorithm was about 1 Gy, either using heterogeneity correction or not. Values of maximum dose calculated with heterogeneity correction showed that dose at CIED was at least equal or higher in 84% of the cases with PBC, 77% with AAA and 67% with AXB than dose obtained with no heterogeneity correction. Conclusion: The dose calculation algorithm and heterogeneity correction did not change the risk categorization. Since higher estimated doses delivered to CIED do not compromise treatment precautions to be taken, it’s recommend that the most sophisticated algorithm available should be used to predict dose at the CIED using heterogeneity correction.

  3. SU-F-T-452: Influence of Dose Calculation Algorithm and Heterogeneity Correction On Risk Categorization of Patients with Cardiac Implanted Electronic Devices Undergoing Radiotherapy

    International Nuclear Information System (INIS)

    Iwai, P; Lins, L Nadler

    2016-01-01

    Purpose: There is a lack of studies with significant cohort data about patients using pacemaker (PM), implanted cardioverter defibrillator (ICD) or cardiac resynchronization therapy (CRT) device undergoing radiotherapy. There is no literature comparing the cumulative doses delivered to those cardiac implanted electronic devices (CIED) calculated by different algorithms neither studies comparing doses with heterogeneity correction or not. The aim of this study was to evaluate the influence of the algorithms Pencil Beam Convolution (PBC), Analytical Anisotropic Algorithm (AAA) and Acuros XB (AXB) as well as heterogeneity correction on risk categorization of patients. Methods: A retrospective analysis of 19 3DCRT or IMRT plans of 17 patients was conducted, calculating the dose delivered to CIED using three different calculation algorithms. Doses were evaluated with and without heterogeneity correction for comparison. Risk categorization of the patients was based on their CIED dependency and cumulative dose in the devices. Results: Total estimated doses at CIED calculated by AAA or AXB were higher than those calculated by PBC in 56% of the cases. In average, the doses at CIED calculated by AAA and AXB were higher than those calculated by PBC (29% and 4% higher, respectively). The maximum difference of doses calculated by each algorithm was about 1 Gy, either using heterogeneity correction or not. Values of maximum dose calculated with heterogeneity correction showed that dose at CIED was at least equal or higher in 84% of the cases with PBC, 77% with AAA and 67% with AXB than dose obtained with no heterogeneity correction. Conclusion: The dose calculation algorithm and heterogeneity correction did not change the risk categorization. Since higher estimated doses delivered to CIED do not compromise treatment precautions to be taken, it’s recommend that the most sophisticated algorithm available should be used to predict dose at the CIED using heterogeneity correction.

  4. Novel nano materials for high performance logic and memory devices

    Science.gov (United States)

    Das, Saptarshi

    After decades of relentless progress, the silicon CMOS industry is approaching a stall in device performance for both logic and memory devices due to fundamental scaling limitations. In order to reinforce the accelerating pace, novel materials with unique properties are being proposed on an urgent basis. This list includes one dimensional nanotubes, quasi one dimensional nanowires, two dimensional atomistically thin layered materials like graphene, hexagonal boron nitride and the more recently the rich family of transition metal di-chalcogenides comprising of MoS2, WSe2, WS2 and many more for logic applications and organic and inorganic ferroelectrics, phase change materials and magnetic materials for memory applications. Only time will tell who will win, but exploring these novel materials allow us to revisit the fundamentals and strengthen our understanding which will ultimately be beneficial for high performance device design. While there has been growing interest in two-dimensional (2D) crystals other than graphene, evaluating their potential usefulness for electronic applications is still in its infancies due to the lack of a complete picture of their performance potential. The fact that the 2-D layered semiconducting di-chalcogenides need to be connected to the "outside" world in order to capitalize on their ultimate potential immediately emphasizes the importance of a thorough understanding of the contacts. This thesis demonstrate that through a proper understanding and design of source/drain contacts and the right choice of number of MoS2 layers the excellent intrinsic properties of this 2D material can be harvested. A comprehensive experimental study on the dependence of carrier mobility on the layer thickness of back gated multilayer MoS 2 field effect transistors is also provided. A resistor network model that comprises of Thomas-Fermi charge screening and interlayer coupling is used to explain the non-monotonic trend in the extracted field effect

  5. Flexible GaN for High Performance, Strainable Radio Frequency Devices (Postprint)

    Science.gov (United States)

    2017-11-02

    wireless systems where consumers will benefit significantly from the high power densities achievable in GaN devices.[8] Further complicating the...future strainable and conformal devices for transmission of radio-frequency (RF) signals over large distances for more efficient wireless communication... power density of traditional RF amplifier materials at different frequencies and wireless generation bands, as well as an image of the flexible GaN

  6. Safety and effectiveness of the INVATEC MO.MA proximal cerebral protection device during carotid artery stenting: results from the ARMOUR pivotal trial.

    Science.gov (United States)

    Ansel, Gary M; Hopkins, L Nelson; Jaff, Michael R; Rubino, Paolo; Bacharach, J Michael; Scheinert, Dierk; Myla, Subbarao; Das, Tony; Cremonesi, Alberto

    2010-07-01

    The multicenter ARMOUR (ProximAl PRotection with the MO.MA Device DUring CaRotid Stenting) trial evaluated the 30-day safety and effectiveness of the MO.MA Proximal Cerebral Protection Device (Invatec, Roncadelle, Italy) utilized to treat high surgical risk patients undergoing carotid artery stenting (CAS). Distal embolic protection devices (EPD) have been traditionally utilized during CAS. The MO.MA device acts as a balloon occlusion "endovascular clamping" system to achieve cerebral protection prior to crossing the carotid stenosis. This prospective registry enrolled 262 subjects, 37 roll-in and 225 pivotal subjects evaluated with intention to treat (ITT) from September 2007 to February 2009. Subjects underwent CAS using the MO.MA device. The primary endpoint, myocardial infarction, stroke, or death through 30 days (30-day major adverse cardiac and cerebrovascular events [MACCE]) was compared to a performance goal of 13% derived from trials utilizing distal EPD. For the ITT population, the mean age was 74.7 years with 66.7% of the cohort being male. Symptomatic patients comprised 15.1% and 28.9% were octogenarians. Device success was 98.2% and procedural success was 93.2%. The 30-day MACCE rate was 2.7% [95% CI (1.0-5.8%)] with a 30-day major stroke rate of 0.9%. No symptomatic patient suffered a stroke during this trial. The ARMOUR trial demonstrated that the MO.MA(R) Proximal Cerebral Protection Device is safe and effective for high surgical risk patients undergoing CAS. The absence of stroke in symptomatic patients is the lowest rate reported in any independently adjudicated prospective multicenter registry trial to date. (c) 2010 Wiley-Liss, Inc.

  7. Surgical treatment of tricuspid valve insufficiency promotes early reverse remodeling in patients with axial-flow left ventricular assist devices.

    Science.gov (United States)

    Maltais, Simon; Topilsky, Yan; Tchantchaleishvili, Vakhtang; McKellar, Stephen H; Durham, Lucian A; Joyce, Lyle D; Daly, Richard C; Park, Soon J

    2012-06-01

    The HeartMate II (Thoratec Corp, Pleasanton, Calif) continuous-flow left ventricular assist device has emerged as the standard of care for patients with advanced heart failure. The objective of this study was to assess the safety and early effectiveness of concomitant tricuspid valve procedures in patients undergoing implantation of a HeartMate II device. From February 2007 to April 2010, 83 patients underwent HeartMate II left ventricular assist device implantation. Of these, 37 patients had concomitant tricuspid valve procedures (32 repairs, 5 replacements) for severe tricuspid regurgitation. The effects of a tricuspid valve procedure on tricuspid regurgitation and right ventricular remodeling were assessed comparing echocardiographic findings at baseline and 30 days after left ventricular assist device implantation. Overall survival was also compared. Patients undergoing a concomitant tricuspid valve procedure had more tricuspid regurgitation (vena contracta, 5.6 ± 2.1 mm vs 2.9 ± 2.0 mm; P tricuspid regurgitation was worse in patients who underwent left ventricular assist device implantation alone (+18.6%), whereas it improved significantly in patients undergoing a concomitant tricuspid valve procedure (-50.2%) (P = .005). A corresponding significant reduction in right ventricular end-diastolic area (33.6% ± 6.2% vs 30.1% ± 9.7%; P = .03) and a trend toward better right ventricular function (55.5% ± 79.7% vs 35.7% ± 60.5%; P = .28) were noted in patients undergoing a concomitant tricuspid valve procedure. Survival was comparable between the 2 groups. In patients with severe tricuspid regurgitation undergoing left ventricular assist device implantation, a concomitant tricuspid valve procedure effectively reduces tricuspid regurgitation and promotes reverse remodeling of the right ventricle. Copyright © 2012 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.

  8. Performance and reliability of TPE-2 device with pulsed high power source

    International Nuclear Information System (INIS)

    Sato, Y.; Takeda, S.; Kiyama, S.

    1987-01-01

    The performance and the reliability of TPE-2 device with pulsed high power sources are described. To obtain the stable high beta plasma, the reproducibility and the reliability of the pulsed power sources must be maintained. A new power crowbar system with high efficiency and the switches with low jitter time are adopted to the bank system. A monitor system which always watches the operational states of the switches is developed too, and applied for the fast rising capacitor banks of TPE-2 device. The reliable operation for the bank has been realized, based on the data of switch monitor system

  9. Turbostratic stacked CVD graphene for high-performance devices

    Science.gov (United States)

    Uemura, Kohei; Ikuta, Takashi; Maehashi, Kenzo

    2018-03-01

    We have fabricated turbostratic stacked graphene with high-transport properties by the repeated transfer of CVD monolayer graphene. The turbostratic stacked CVD graphene exhibited higher carrier mobility and conductivity than CVD monolayer graphene. The electron mobility for the three-layer turbostratic stacked CVD graphene surpassed 10,000 cm2 V-1 s-1 at room temperature, which is five times greater than that for CVD monolayer graphene. The results indicate that the high performance is derived from maintenance of the linear band dispersion, suppression of the carrier scattering, and parallel conduction. Therefore, turbostratic stacked CVD graphene is a superior material for high-performance devices.

  10. High density high performance plasma with internal diffusion barrier in Large Helical Device

    International Nuclear Information System (INIS)

    Sakamoto, R.; Kobayashi, M.; Miyazawa, J.

    2008-10-01

    A attractive high density plasma operational regime, namely an internal diffusion barrier (IDB), has been discovered in the intrinsic helical divertor configuration on the Large Helical Device (LHD). The IDB which enables core plasma to access a high density/high pressure regime has been developed. It is revealed that the IDB is reproducibly formed by pellet fueling in the magnetic configurations shifted outward in major radius. Attainable central plasma density exceeds 1x10 21 m -3 . Central pressure reaches 1.5 times atmospheric pressure and the central β value becomes fairly high even at high magnetic field, i.e. β(0)=5.5% at B t =2.57 T. (author)

  11. Two Different Maintenance Strategies in the Hospital Environment: Preventive Maintenance for Older Technology Devices and Predictive Maintenance for Newer High-Tech Devices

    OpenAIRE

    Sezdi, Mana

    2016-01-01

    A maintenance program generated through the consideration of characteristics and failures of medical equipment is an important component of technology management. However, older technology devices and newer high-tech devices cannot be efficiently managed using the same strategies because of their different characteristics. This study aimed to generate a maintenance program comprising two different strategies to increase the efficiency of device management: preventive maintenance for older tec...

  12. Electron beam gun with kinematic coupling for high power RF vacuum devices

    Science.gov (United States)

    Borchard, Philipp

    2016-11-22

    An electron beam gun for a high power RF vacuum device has components joined by a fixed kinematic coupling to provide both precise alignment and high voltage electrical insulation of the components. The kinematic coupling has high strength ceramic elements directly bonded to one or more non-ductile rigid metal components using a high temperature active metal brazing alloy. The ceramic elements have a convex surface that mates with concave grooves in another one of the components. The kinematic coupling, for example, may join a cathode assembly and/or a beam shaping focus electrode to a gun stem, which is preferably composed of ceramic. The electron beam gun may be part of a high power RF vacuum device such as, for example, a gyrotron, klystron, or magnetron.

  13. Simulation study of a high power density rectenna array for biomedical implantable devices

    Science.gov (United States)

    Day, John; Yoon, Hargsoon; Kim, Jaehwan; Choi, Sang H.; Song, Kyo D.

    2016-04-01

    The integration of wireless power transmission devices using microwaves into the biomedical field is close to a practical reality. Implanted biomedical devices need a long lasting power source or continuous power supply. Recent development of high efficiency rectenna technology enables continuous power supply to these implanted devices. Due to the size limit of most of medical devices, it is imperative to minimize the rectenna as well. The research reported in this paper reviews the effects of close packing the rectenna elements which show the potential of directly empowering the implanted devices, especially within a confined area. The rectenna array is tested in the X band frequency range.

  14. PRE-MARKET CLINICAL EVALUATIONS OF INNOVATIVE HIGH-RISK MEDICAL DEVICES IN EUROPE

    DEFF Research Database (Denmark)

    Hulstaert, F.; Neyt, M.; Vinck, I.

    2012-01-01

    data are available? We studied the premarket clinical evaluation of innovative high-risk medical devices in Europe compared with the US, and with medicines, where appropriate. Methods: The literature and regulatory documents were checked. Representatives from industry, Competent Authorities, Notified...... of premarket trials in Europe and number of patients exposed, but failed as this information is not made public. Furthermore, the Helsinki Declaration is not followed with respect to the registration and publication of premarket trials. Conclusions: For innovative high-risk devices, new EU legislation should...

  15. Pharmacokinetics of Imipenem/Cilastatin Burn Intensive Care Unit Patients Undergoing High-Dose Continuous Venovenous Hemofiltration.

    Science.gov (United States)

    Boucher, Bradley A; Hudson, Joanna Q; Hill, David M; Swanson, Joseph M; Wood, G Christopher; Laizure, S Casey; Arnold-Ross, Angela; Hu, Zhe-Yi; Hickerson, William L

    2016-12-01

    High-dose continuous venovenous hemofiltration (CVVH) is a continuous renal replacement therapy (CRRT) used frequently in patients with burns. However, antibiotic dosing is based on inference from studies assessing substantially different methods of CRRT. To address this knowledge gap for imipenem/cilastatin (I/C), we evaluated the systemic and extracorporeal clearances (CLs) of I/C in patients with burns undergoing high-dose CVVH. Prospective clinical pharmacokinetic study. Ten adult patients with burns receiving I/C for a documented infection and requiring high-dose CVVH were studied. Blood and effluent samples for analysis of I/C concentrations were collected for up to 6 hours after the I/C infusion for calculation of I/C total CL (CL T otal ), CL by CVVH (CL HF ), half-life during CVVH, volume of distribution at steady state (Vd ss ), and the percentage of drug eliminated by CVVH. In this patient sample, the mean age was 50 ± 17 years, total body surface area burns was 23 ± 27%, and 80% were male. Nine patients were treated with high-dose CVVH for acute kidney injury and one patient for sepsis. The mean delivered CVVH dose was 52 ± 14 ml/kg/hour (range 32-74 ml/kg/hr). The imipenem CL HF was 3.27 ± 0.48 L/hour, which accounted for 23 ± 4% of the CL T otal (14.74 ± 4.75 L/hr). Cilastatin CL HF was 1.98 ± 0.56 L/hour, which accounted for 45 ± 19% of the CL T otal (5.16 + 2.44 L/hr). The imipenem and cilastatin half-lives were 1.77 ± 0.38 hours and 4.21 ± 2.31 hours, respectively. Imipenem and cilastatin Vd ss were 35.1 ± 10.3 and 32.8 ± 13.8 L, respectively. Efficient removal of I/C by high-dose CVVH, a high overall clearance, and a high volume of distribution in burn intensive care unit patients undergoing this CRRT method warrant aggressive dosing to treat serious infections effectively depending on the infection site and/or pathogen. © 2016 Pharmacotherapy Publications, Inc.

  16. Construction of control and instrumentation devices of high voltage power supply of double chamber plasma nitrogen

    International Nuclear Information System (INIS)

    Saminto; Eko Priyono; Sugeng Riyanto

    2013-01-01

    A control and instrumentation devices of high voltage power supply of double chamber plasma nitrogen have been made. This device consists of the software and hardware component. Hardware component consists of SCR phase angle controller LPC-50HDA type, T100MD1616+ PLC, high voltage transformer and voltage rectifier system. Software component used a LADDER program and TBasic serves to control of the high voltage output. The components in these devices have been tested in the double chamber plasma nitrogen. Its performance meet with the design criteria that can supply of plasma nitrogen operation voltage in the range 290 Vdc to 851 Vdc with glow discharge current 0.4 A to 1.4 A. In general it can be said that the control and instrumentation devices of high voltage power supply is ready for use at the double chamber plasma nitrogen device. (author)

  17. Design of high efficiency and energy saving aeration device for aquaculture

    Science.gov (United States)

    Liu, Sibo

    2017-03-01

    Energy efficient aeration device for aquaculture, in line with "by more than a generation, dynamic aeration" train of thought for technical design and improvement. Removable aeration terminal as the core, multi-level water to improve the method, the mobile fading pore aeration, intelligent mobile and open and close as the main function, aimed at solving the existing pond aeration efficiency, low energy consumption is high, the function of a single problem. From energy saving, efficiency, biological bacteria on the three directions, the aquaculture industry of energy conservation and emissions reduction. Device of the main advantages are: 1, original mobile fading aerator on the one hand, to expand the scope of work, playing a micro porous aeration of dissolved oxygen with high efficiency and to achieve "by more than a generation", on the other hand, through the sports equipment, stir the mixture of water, the water surface of photosynthesis of plants rich in dissolved oxygen input parts of the tank, compared to the stillness of the aerator can be more fully dissolved oxygen.2, through the opening of the pressure sensor indirect control device, can make the equipment timely and stop operation, convenient in use at the same time avoid the waste of energy.3, the biofilm suspension in aeration terminal, can be accomplished by nitration of microbial multi-level water improvement, still can make biofilm increase rate of netting in the movement process, the biological and mechanical aerobic promote each other, improve the efficiency of both. In addition, the device has small power consumption, low cost of characteristics. And have a certain degree of technical barriers, have their own intellectual property rights, and high degree of product market demand, easily accepted by customers, has a very high popularization value.

  18. A comparison of outcomes involving highly cohesive, form-stable breast implants from two manufacturers in patients undergoing primary breast augmentation.

    Science.gov (United States)

    Jewell, Mark L; Jewell, James L

    2010-01-01

    Although there have been reports of single-surgeon outcomes with highly cohesive, form-stable silicone gel implants in women undergoing primary breast augmentation, there has been only one study published that compares the outcomes between the Allergan 410 and the Mentor CPG devices. The goal of the study is to compare outcomes in each cohort and to determine if quality systems and processes would have an impact on lowering the surgical revision rate, as compared to published reports for round gel implants and form-stable implants. Patients selected for the study were required to meet predefined inclusion criteria and general indications for breast augmentation. All subjects were treated uniformly with extensive informed consent prior to surgery. The entire process of breast augmentation (patient assessment, informed consent, the surgical procedure itself and postoperative instructions) was identical between the two groups. Patients were not randomized, as the studies did not start at the same time. The process for management of each patient was based on adaptation of the Toyota Production System and Lean Manufacturing, with emphasis on achieving operational excellence in the use of planning templates for surgery, including accurate management of patient expectations regarding size outcome. Outcomes data included physical breast measurements, quality of life metrics, and patient/surgeon satisfaction assessment. Adverse events were compared against published data for breast implants. Follow-up ranged between 20-77 months (Allergan 410) and 16-77 months (Mentor CPG). The outcome data indicate that these devices produce natural-appearing breasts with extremely low aggregate reoperation rate (4.2%). Only 0.8% of the reoperations were attributable to surgeon-related factors. There were no reoperations to correct mismanaged size expectations during the course of each study. There were 13 pregnancies and no difficulties with lactation were reported. Rippling (lateral

  19. A multicenter retrospective comparison of goniotomy versus trabecular bypass device implantation in glaucoma patients undergoing cataract extraction

    Directory of Open Access Journals (Sweden)

    Dorairaj SK

    2018-04-01

    Full Text Available Syril K Dorairaj,1 Malik Y Kahook,2 Blake K Williamson,3 Leonard K Seibold,4 Mohammed K ElMallah,5 Inder P Singh6 On behalf of the KDB Goniotomy Study Group 1Department of Ophthalmology, Mayo Clinic, Jacksonville, FL, 2School of Medicine, University of Colorado, Denver, CO, 3Williamson Eye Center, Baton Rouge, LA, 4School of Medicine, University of Colorado, Aurora, CO, 5Ocala Eye, Ocala, FL, 6The Eye Center of Racine and Kenosha, Kenosha, WI, USA Purpose: The aim of this study was to compare intraocular pressure (IOP outcomes in eyes with cataract and glaucoma undergoing phacoemulsification (phaco in combination with goniotomy using the Kahook Dual Blade (KDB or implantation of a single iStent trabecular bypass device.Methods: Retrospective analysis of IOP and IOP-lowering medication reduction in eyes undergoing phaco-goniotomy with KDB (n=237 or phaco-iStent (n=198. Preoperative, intraoperative, and postoperative data were collected through 6 months of follow-up. Outcome measures included mean IOP reduction, mean reduction in IOP-lowering medications, and the proportion of eyes achieving ≥20% IOP reduction or ≥1 medication reduction from baseline.Results: Mean IOP in the phaco-goniotomy with KDB group decreased from 17.9±4.4 mmHg at baseline to 13.6±2.7 mmHg at Month 6 (P<0.001, with mean medication use decreasing from 1.7±0.9 to 0.6±1.0 (P<0.001. In the phaco-iStent group, mean IOP decreased from 16.7±4.4 mmHg to 13.9±2.7 mmHg (P<0.001, with mean IOP-lowering medication use decreasing from 1.9±0.9 to 1.0±1.0 (P<0.001. Mean IOP reduction from baseline was significantly greater in the phaco-goniotomy with KDB group at Month 6 (phaco-goniotomy with KDB −4.2 mmHg [23.7%] vs phaco-iStent −2.7 mmHg [16.4%]; P<0.001. IOP-lowering medication reduction was greater in the phaco-goniotomy with KDB group compared to the phaco-iStent group (1.1 vs 0.9 medications, respectively; P=0.001. The most common adverse event was IOP spikes

  20. Adjustable mounting device for high-volume production of beam-shaping systems for high-power diode lasers

    Science.gov (United States)

    Haag, Sebastian; Bernhardt, Henning; Rübenach, Olaf; Haverkamp, Tobias; Müller, Tobias; Zontar, Daniel; Brecher, Christian

    2015-02-01

    In many applications for high-power diode lasers, the production of beam-shaping and homogenizing optical systems experience rising volumes and dynamical market demands. The automation of assembly processes on flexible and reconfigurable machines can contribute to a more responsive and scalable production. The paper presents a flexible mounting device designed for the challenging assembly of side-tab based optical systems. It provides design elements for precisely referencing and fixating two optical elements in a well-defined geometric relation. Side tabs are presented to the machine allowing the application of glue and a rotating mechanism allows the attachment to the optical elements. The device can be adjusted to fit different form factors and it can be used in high-volume assembly machines. The paper shows the utilization of the device for a collimation module consisting of a fast-axis and a slow-axis collimation lens. Results regarding the repeatability and process capability of bonding side tab assemblies as well as estimates from 3D simulation for overall performance indicators achieved such as cycle time and throughput will be discussed.

  1. The effects of high-load strength training with protein- or nonprotein-containing nutritional supplementation in patients undergoing dialysis

    DEFF Research Database (Denmark)

    Mølsted, Stig; Harrison, Adrian Paul; Eidemak, Inge

    2013-01-01

    or a nonprotein drink after every training session. MAIN OUTCOME MEASURE: Muscle strength and power were tested using the good strength equipment and the leg extensor power rig. Physical performance and function were assessed using a chair stand test and the Short Form 36 questionnaire. Muscle fiber type size......OBJECTIVE: The aim of this study was to investigate the effects of high-load strength training and protein intake in patients undergoing dialysis with a focus on muscle strength, physical performance, and muscle morphology. DESIGN: This was a randomized controlled study conducted in three dialysis...... centers. SUBJECTS: Subjects for the study included 29 patients undergoing dialysis. INTERVENTION: The participants went through a control period of 16 weeks before completing 16 weeks of strength training. Before the training period, the participants were randomly assigned to receive a protein...

  2. Investigating the motives of patients with knee OA undergoing a TKR

    DEFF Research Database (Denmark)

    Traumer, Line; Sørensen, Erik Elgaard; Kusk, Kathrine Hoffmann

    2018-01-01

    , a qualitatively assessment of what actually affects the patient's decision to undergo TKR would be important. Therefore, the purpose of this study was to investigate the motives of patients with knee OA choosing to undergo TKR and to explore the factors considered important during their decision?making process...... was a legitimate argument among patients. The prospect of avoiding taking high doses of pain?relieving medication and hearing positive experiences of others who had undergone TKR motivated patients to undergo TKR. However, negative experiences of others were neglected. Conclusions Patients' decision?making process...... revealed that the interaction between doctor and patient emerged as a factor highly influential on patients' decision?making process with patients choosing the treatment option suggested by the doctor. Using x?rays, revealing no cartilage between the bones, as a reason for choosing to undergo TKR...

  3. High Total Ionizing Dose and Temperature Effects on Micro- and Nano-electronic Devices

    International Nuclear Information System (INIS)

    Gaillardin, M.; Martinez, M.; Paillet, P.; Leray, J.L.; Marcandella, C.; Duhamel, O.; Raine, M.; Richard, N.; Girard, S.; Ouerdane, Y.; Boukenter, A.; Goiffon, V.; Magnan, P.; Andrieu, F.; Barraud, S.; Faynot, O.

    2013-06-01

    This paper investigates the vulnerability of several micro- and nano-electronic technologies to a mixed harsh environment including high total ionizing dose at MGy levels and high temperature. Such operating conditions have been revealed recently for several applications like new security systems in existing or future nuclear power plants, fusion experiments, or deep space missions. In this work, the competing effects already reported in literature of ionizing radiations and temperature are characterized in elementary devices made of MOS transistors from several technologies. First, devices are irradiated using a radiation laboratory X-ray source up to MGy dose levels at room temperature. Devices are grounded during irradiation to simulate a circuit which waits for a wake up signal, representing most of the lifetime of an integrated circuit operating in a harsh environment. Devices are then annealed at several temperatures to discuss the post-irradiation behavior and to determine whether an elevated temperature is an issue or not for circuit function in mixed harsh environments. (authors)

  4. Multifaceted Comparison of Two Cryotherapy Devices Used After Total Knee Arthroplasty: Cryotherapy Device Comparison.

    Science.gov (United States)

    Schinsky, Mark F; McCune, Christine; Bonomi, Judith

    2016-01-01

    Some form of cryotherapy used after total knee arthroplasty is commonplace. However, various factors determine the specific device deployed. This study aimed to answer the following questions: : A group of 100 patients undergoing primary total knee arthroplasty by a single surgeon were enrolled in an institutional review board-approved, prospective study and randomized to receive either a circulating cold water or ice/gel pack cryotherapy device postoperatively. Demographic, pain, swelling, blood loss, range of motion, compliance, satisfaction, and adverse event outcomes were recorded until 6 weeks after surgery. Hospital staff satisfaction and economic variables were examined. The ice/gel pack cryotherapy wrap was noninferior to the cold water cryotherapy device for any patient outcome measured. Average pain level at 6 weeks postoperative was significantly less in the ice/gel pack cryotherapy wrap group. Hospital staff satisfaction was higher with the ice/gel pack cryotherapy wrap.Substantial economic savings can be realized at our institution by switching to the lower cost cryotherapy device. In this study, the lower cost ice/gel pack cryotherapy wrap was noninferior to the circulating ice water cryotherapy device with respect to objective patient outcomes and subjective patient satisfaction after total knee arthroplasty. Hospital staff satisfaction and economic considerations also favor the ice/gel pack compression cryotherapy wraps.

  5. Optimization of a variable-stiffness skin for morphing high-lift devices

    NARCIS (Netherlands)

    Thuwis, G.A.A.; Abdalla, M.M.; Gürdal, Z.

    2010-01-01

    One of the possibilities for the next generation of smart high-lift devices is to use a seamless morphing structure. A passive composite variable-stiffness skin as a solution to the dilemma of designing the structure to have high enough stiffness to withstand aerodynamic loading and low stiffness to

  6. An audit of pressure sores caused by intermittent compression devices used to prevent venous thromboembolism.

    Science.gov (United States)

    Skillman, Joanna; Thomas, Sunil

    2011-12-01

    When intermittent compression devices (ICDs) are used to prevent venous thromboembolism (VTE) they can cause pressure sores in a selected group of women, undergoing long operations. A prospective audit pre and post intervention showed a reduced risk with an alternative device, without increasing the risk of VTE.

  7. Toward flexible polymer and paper-based energy storage devices

    Energy Technology Data Exchange (ETDEWEB)

    Nyholm, Leif [Department of Materials Chemistry, The Aangstroem Laboratory, Uppsala University, Box 538, SE-751 21 Uppsala (Sweden); Nystroem, Gustav; Mihranyan, Albert; Stroemme, Maria [Nanotechnology and Functional Materials, Department of Engineering Sciences, The Aangstroem Laboratory, Uppsala University, Box 534, SE-751 21 Uppsala (Sweden)

    2011-09-01

    All-polymer and paper-based energy storage devices have significant inherent advantages in comparison with many currently employed batteries and supercapacitors regarding environmental friendliness, flexibility, cost and versatility. The research within this field is currently undergoing an exciting development as new polymers, composites and paper-based devices are being developed. In this report, we review recent progress concerning the development of flexible energy storage devices based on electronically conducting polymers and cellulose containing composites with particular emphasis on paper-based batteries and supercapacitors. We discuss recent progress in the development of the most commonly used electronically conducting polymers used in flexible device prototypes, the advantages and disadvantages of this type of energy storage devices, as well as the two main approaches used in the manufacturing of paper-based charge storage devices. (Copyright copyright 2011 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  8. Integrated Production of Ultra-Low Defect GaN Films and Devices for High-Power Amplifiers, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — High quality GaN epitaxial films are key to current efforts for development of both high-power/high-speed electronic devices and optoelectronic devices. In fact,...

  9. High sensitivity high-resolution full range relaxometry using a fast mechanical sample shuttling device and a cryo-probe

    Energy Technology Data Exchange (ETDEWEB)

    Chou, Ching-Yu [Université Paris-Saclay, NIMBE, CEA, CNRS (France); Chu, Minglee [Academia Sinica, Institute of Physics (China); Chang, Chi-Fon [Academia Sinica, Genomics Research Center (China); Yu, Tsunai; Huang, Tai-huang, E-mail: bmthh@gate.sinica.edu.tw [Academia Sinica, Institute of Biomedical Science (China); Sakellariou, Dimitris, E-mail: dimitrios.sakellariou@cea.fr [Université Paris-Saclay, NIMBE, CEA, CNRS (France)

    2016-11-15

    Field-dependent NMR studies of bio-molecular systems using a sample shuttling hardware operating on a high-field NMR apparatus have provided valuable structural and dynamic information. We have recently published a design of a compact sample transportation device, called “field-cycler”, which was installed in a commercial spectrometer and which provided highly precise positioning and stability during high speed shuttling. In this communication, we demonstrate the first use of a sample shuttling device on a commercial high field standard bore NMR spectrometer, equipped with a commercial triple resonance cryogenically cooled NMR probe. The performance and robustness of the hardware operating in 1D and 2D field cycling experiments, as well as the impact of the sample shuttling time on the signal intensity are discussed.

  10. SKLUST device for high-precision gluing of MWPC

    International Nuclear Information System (INIS)

    Amaglobeli, N.S.; Burov, R.V.; Sakandelidze, R.M.; Sakhelashvili, T.M.; Chiladze, B.G.; Glonti, G.L.; Glonti, L.N.

    2005-01-01

    The SKLUST device has been created for gluing precision plane-parallel anode, cathode of spacer bars and integral anode and cathode frames of the MWPCs or flat surfaces of the large-area cathode planes for them in the case that thin copper clad stesalit or glass-cloth-base laminate is used as the cathode, for example, for the CSC chambers. In contrast to usual gluing, in this device the glued components are not pressed to each other. SKLUST allows making high-precision products in laboratory conditions without preliminarily machining its components and receiving a precision article practically for any area at the plane parallelism from ±0.030 up to ±0.006 mm using a non-calibrated sheet of the foiled (or unfoiled) stesalit, glass-cloth-base laminate or other flexible materials to a tolerance for the thickness ±0.2-0.5 mm or worse. On the biggest of the existing devices it is possible to fabricate an article with the maximal sizes 2400x250 mm 2 at the thickness accuracy (6±0.015) mm (maximum deviation). Whereas in the technological cycle machining of blanks to the thickness or application of exact blanks is completely excluded, the manufacturing process becomes simpler, and the price of the articles essentially reduces, especially for mass production

  11. High-efficiency and heavily doped organic light-emitting devices based on quench-resistant red iridium complex

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Qi [State Key Laboratory of Electronic Thin Films and Integrated Devices, School of Optoelectronic Information, University of Electronic Science and Technology of China, Chengdu 610054 (China); Yu, Junsheng, E-mail: jsyu@uestc.edu.cn [State Key Laboratory of Electronic Thin Films and Integrated Devices, School of Optoelectronic Information, University of Electronic Science and Technology of China, Chengdu 610054 (China); Zhao, Juan; Wang, Jun [State Key Laboratory of Electronic Thin Films and Integrated Devices, School of Optoelectronic Information, University of Electronic Science and Technology of China, Chengdu 610054 (China); Li, Ming [College of Chemistry, Sichuan University, Chengdu 610064 (China); Lu, Zhiyun, E-mail: luzhiyun@scu.edu.cn [College of Chemistry, Sichuan University, Chengdu 610064 (China)

    2013-02-15

    Highly efficient red phosphorescent organic light-emitting devices had been fabricated using a new iridium complex, bis[2-(9,9-dimethyl-9H-fluoren-2-yl) benzothiazolato-N,C{sup 2'}]iridium(III) (acetylacetonate) [(fbt){sub 2}Ir(acac)] as phosphor. With a high doping concentration of 15 wt%, the device exhibited a maximum luminance efficiency, power efficiency and external quantum efficiency (EQE) of 35.2 cd/A, 21.3 lm/W, 18.2%, respectively, indicating an excellent quench-resistant property of (fbt){sub 2}Ir(acac). The results are appealing towards the development of 'easy-to-make' OLEDs. It has been demonstrated that the high efficiency arises from more balanced charge carriers in the emissive layer. - Highlight: Black-Right-Pointing-Pointer We obtained efficient OLEDs based on newly synthesized quench-resistant phosphor. Black-Right-Pointing-Pointer Peak performance was obtained with 15 wt% (fbt){sub 2}Ir(acac) doped device. Black-Right-Pointing-Pointer Our devices gave one of the best performance among heavily-doped red devices. Black-Right-Pointing-Pointer Balanced carrier transport is crucial for the high performance of our devices.

  12. Integrated Production of Ultra-Low Defect GaN Films and Devices for High-Power Amplifiers, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — High quality GaN epitaxial films are one of the keys to current efforts for development of both high-power/high-speed electronic devices and optoelectronic devices....

  13. A broadband high-efficiency Doherty power amplifier using symmetrical devices

    Science.gov (United States)

    Cheng, Zhiqun; Zhang, Ming; Li, Jiangzhou; Liu, Guohua

    2018-04-01

    This paper proposes a method for broadband and high-efficiency amplification of Doherty power amplifier (DPA) using symmetric devices. In order to achieve the perfect load modulation, the carrier amplifier output circuit total power length is designed to odd multiple of 90°, and the peak amplifier output total power length is designed to even multiple of 180°. The proposed method is demonstrated by designing a broadband high-efficiency DPA using identical 10-W packaged GaN HEMT devices. Measurement results show that over 51% drain efficiency is achieved at 6-dB back-off power, over the frequency band of 1.9–2.4 GHz. Project supported by the National Natural Science Foundation of China (No. 60123456), the Zhejiang Provincial Natural Science Foundation of China (No. LZ16F010001), and the Zhejiang Provincial Public Technology Research Project (No. 2016C31070).

  14. High-efficiency terahertz polarization devices based on the dielectric metasurface

    Science.gov (United States)

    Zhou, Jian; Wang, JingJing; Guo, Kai; Shen, Fei; Zhou, Qingfeng; Zhiping yin; Guo, Zhongyi

    2018-02-01

    Metasurfaces are composed of the subwavelength structures, which can be used to manipulate the amplitude, phase, and polarization of incident electromagnetic waves efficiently. Here, we propose a novel type of dielectric metasurface based on crystal Si for realizing to manipulate the terahertz wave, in which by varying the geometric sizes of the Si micro-bricks, the transmitting phase of the terahertz wave can almost span over the entire 2π range for both of the x-polarization and y-polarization simultaneously, while keeping the similarly high-transmission amplitudes (over 90%). At the frequency of 1.0 THz, we have successfully designed a series of controllable THz devices, such as the polarization-dependent beam splitter, polarization-independent beam deflector and the focusing lenses based on the designed metasurfaces. Our designs are easy to fabricate and can be promising in developing high-efficiency THz functional devices.

  15. Usefulness of vessel-sealing devices for peripartum hysterectomy: a retrospective cohort study.

    Science.gov (United States)

    Rossetti, Diego; Vitale, Salvatore Giovanni; Bogani, Giorgio; Rapisarda, Agnese Maria Chiara; Gulino, Ferdinando Antonio; Frigerio, Luigi

    2015-09-01

    To evaluate the feasibility to perform peripartum hysterectomy (PH) with the introduction of LigaSure™ vessels-sealing device (LVSD) and how it influenced the surgical outcomes. We retrospectively evaluated procedures and outcome of women undergoing PH during the period between January 2001 and October 2013. Perioperative surgical results of patients undergoing PH using LVSD were compared to patients undergoing PH without LVSD. Forty-nine subjects had PH during the study period. Twenty (41%) hysterectomies were performed for placenta accreta, 8 (16%) for placenta previa, 21 (43%) for atony. Twenty-three subjects had PH using LVSD and 26 subjects had hysterectomy without the use of this device. We observe significant differences in estimated blood loss (p = 0.001), massive blood transfusions (>10 units RBC) (p = 0.025), operative time (p = 0.06). No difference in term of hospital stay and complications were observed (p = 0.78 and p = 0.35). One patient for each group had intraoperative complication (p = 0.9). The use of LVSD during PH does not increase operative complications, blood loss, and operative time in comparison to standard procedure.

  16. Loss and thermal redistributed modulation methods for three-level neutral-point-clamped wind power inverter undergoing Low Voltage Ride Through

    DEFF Research Database (Denmark)

    Ma, Ke; Blaabjerg, Frede

    2012-01-01

    The three-level neutral-point-clamped (3L-NPC) converter is a promising multilevel topology in the application of mega-watts wind power generation system. However, the growing requirements by grid codes may impose high stress and even give reliability problem to this converter topology. This paper...... modulation methods, the thermal distribution in the 3L-NPC wind power inverter undergoing LVRT becomes more equal, and the junction temperature of the most stressed devices can be also relieved. Also the control ability of DC-bus neutral point potential, which is one of the crucial considerations for the 3L...

  17. A pocket device for high-throughput optofluidic holographic microscopy

    Science.gov (United States)

    Mandracchia, B.; Bianco, V.; Wang, Z.; Paturzo, M.; Bramanti, A.; Pioggia, G.; Ferraro, P.

    2017-06-01

    Here we introduce a compact holographic microscope embedded onboard a Lab-on-a-Chip (LoC) platform. A wavefront division interferometer is realized by writing a polymer grating onto the channel to extract a reference wave from the object wave impinging the LoC. A portion of the beam reaches the samples flowing along the channel path, carrying their information content to the recording device, while one of the diffraction orders from the grating acts as an off-axis reference wave. Polymeric micro-lenses are delivered forward the chip by Pyro-ElectroHydroDynamic (Pyro-EHD) inkjet printing techniques. Thus, all the required optical components are embedded onboard a pocket device, and fast, non-iterative, reconstruction algorithms can be used. We use our device in combination with a novel high-throughput technique, named Space-Time Digital Holography (STDH). STDH exploits the samples motion inside microfluidic channels to obtain a synthetic hologram, mapped in a hybrid space-time domain, and with intrinsic useful features. Indeed, a single Linear Sensor Array (LSA) is sufficient to build up a synthetic representation of the entire experiment (i.e. the STDH) with unlimited Field of View (FoV) along the scanning direction, independently from the magnification factor. The throughput of the imaging system is dramatically increased as STDH provides unlimited FoV, refocusable imaging of samples inside the liquid volume with no need for hologram stitching. To test our embedded STDH microscopy module, we counted, imaged and tracked in 3D with high-throughput red blood cells moving inside the channel volume under non ideal flow conditions.

  18. The New 3D Printed Left Atrial Appendage Closure with a Novel Holdfast Device: A Pre-Clinical Feasibility Animal Study.

    Directory of Open Access Journals (Sweden)

    M Brzeziński

    Full Text Available Many patients undergoing cardiac surgery have risk factors for both atrial fibrillation (AF and stroke. The left atrial appendage (LAA is the primary site for thrombi formation. The most severe complication of emboli derived from LAA is stroke, which is associated with a 12-month mortality rate of 38% and a 12-month recurrence rate of 17%. The most common form of treatment for atrial fibrillation and stroke prevention is the pharmacological therapy with anticoagulants. Nonetheless this form of therapy is associated with high risk of major bleeding. Therefore LAA occlusion devices should be tested for their ability to reduce future cerebral ischemic events in patients with high-risk of haemorrhage.The aim of this study was to evaluate the safety and feasibility of a novel left atrial appendage exclusion device with a minimally invasive introducer in a swine model.A completely novel LAA device, which is composed of two tubes connected together using a specially created bail, was designed using finite element modelling (FEM to obtain an optimal support force of 36 N at the closure line. The monolithic form of the occluder was obtained by using additive manufacturing of granular PA2200 powder with the technology of selective laser sintering (SLS. Fifteen swine were included in the feasibility tests, with 10 animals undergoing fourteen days of follow-up and 5 animals undergoing long-term observation of 3 months. For one animal, the follow-up was further prolonged to 6 months. The device was placed via minithoracotomy. After the observation period, all of the animals were euthanized, and their hearts were tested for LAA closure and local inflammatory and tissue response.After the defined observation period, all fifteen hearts were explanted. In all cases the full closure of the LAA was achieved. The macroscopic and microscopic evaluation of the explanted hearts showed that all devices were securely integrated in the surrounding tissues. No

  19. Confinement studies of a high current density RFP in the Extrap T1 Upgrade device

    International Nuclear Information System (INIS)

    Drake, J.R.; Brzozowski, J.H.; Brunsell, P.; Hellblom, G.; Karlsson, P.; Mazur, S.; Nordlund, P.; Welander, A.; Zastrow, K.D.

    1992-01-01

    Confinement studies have been carried out on the Extrap T1 device operated in the reversed field pinch (RFP) mode. Extrap T1 is a small device with a major radius of R=0.5 m and a high aspect ratio, R/a=8.9. For these experiments, the device has been operated with a resistive shell with measured, toroidally-averaged flux penetration times of τ sv = 500μs (vertical) and τ sR =300μs (radial). The pulse lengths are about 600 μs, which is slightly longer than the shell penetration time. The purpose of these experiments is to study energy confinement in a high aspect-ratio, high current-density RFP device with a resistive shell. The device can be operated with high current densities which exceed 20 MAm -2 on axis. For these discharges, the average electron density is relatively high, ≅ 1x10 20 m -3 . Therefore, although the average current density exceeds 5 MAm -2 , the important parameter / ≅ I/N is maintained less than 1x10 -13 Am, where N is the line density. The plasma diagnostics for the device include a single chord CO 2 laser interferometer ( ), single point Thomson scattering (T e , n o ), VUV and visible spectroscopy (T e , Z eff ) surface barrier diodes for soft X-ray measurements (T e ), bolometry (P rad ), surface probes (Γ p ,T i ) and comprehensive magnetic diagnostics for both equilibrium and magnetic fluctuation studies. (author) 5 refs., 1 fig., 1 tab

  20. UNIPIC code for simulations of high power microwave devices

    International Nuclear Information System (INIS)

    Wang Jianguo; Zhang Dianhui; Wang Yue; Qiao Hailiang; Li Xiaoze; Liu Chunliang; Li Yongdong; Wang Hongguang

    2009-01-01

    In this paper, UNIPIC code, a new member in the family of fully electromagnetic particle-in-cell (PIC) codes for simulations of high power microwave (HPM) generation, is introduced. In the UNIPIC code, the electromagnetic fields are updated using the second-order, finite-difference time-domain (FDTD) method, and the particles are moved using the relativistic Newton-Lorentz force equation. The convolutional perfectly matched layer method is used to truncate the open boundaries of HPM devices. To model curved surfaces and avoid the time step reduction in the conformal-path FDTD method, CP weakly conditional-stable FDTD (WCS FDTD) method which combines the WCS FDTD and CP-FDTD methods, is implemented. UNIPIC is two-and-a-half dimensional, is written in the object-oriented C++ language, and can be run on a variety of platforms including WINDOWS, LINUX, and UNIX. Users can use the graphical user's interface to create the geometric structures of the simulated HPM devices, or input the old structures created before. Numerical experiments on some typical HPM devices by using the UNIPIC code are given. The results are compared to those obtained from some well-known PIC codes, which agree well with each other.

  1. UNIPIC code for simulations of high power microwave devices

    Science.gov (United States)

    Wang, Jianguo; Zhang, Dianhui; Liu, Chunliang; Li, Yongdong; Wang, Yue; Wang, Hongguang; Qiao, Hailiang; Li, Xiaoze

    2009-03-01

    In this paper, UNIPIC code, a new member in the family of fully electromagnetic particle-in-cell (PIC) codes for simulations of high power microwave (HPM) generation, is introduced. In the UNIPIC code, the electromagnetic fields are updated using the second-order, finite-difference time-domain (FDTD) method, and the particles are moved using the relativistic Newton-Lorentz force equation. The convolutional perfectly matched layer method is used to truncate the open boundaries of HPM devices. To model curved surfaces and avoid the time step reduction in the conformal-path FDTD method, CP weakly conditional-stable FDTD (WCS FDTD) method which combines the WCS FDTD and CP-FDTD methods, is implemented. UNIPIC is two-and-a-half dimensional, is written in the object-oriented C++ language, and can be run on a variety of platforms including WINDOWS, LINUX, and UNIX. Users can use the graphical user's interface to create the geometric structures of the simulated HPM devices, or input the old structures created before. Numerical experiments on some typical HPM devices by using the UNIPIC code are given. The results are compared to those obtained from some well-known PIC codes, which agree well with each other.

  2. Metasurfaces Based on Phase-Change Material as a Reconfigurable Platform for Multifunctional Devices

    Science.gov (United States)

    Raeis-Hosseini, Niloufar; Rho, Junsuk

    2017-01-01

    Integration of phase-change materials (PCMs) into electrical/optical circuits has initiated extensive innovation for applications of metamaterials (MMs) including rewritable optical data storage, metasurfaces, and optoelectronic devices. PCMs have been studied deeply due to their reversible phase transition, high endurance, switching speed, and data retention. Germanium-antimony-tellurium (GST) is a PCM that has amorphous and crystalline phases with distinct properties, is bistable and nonvolatile, and undergoes a reliable and reproducible phase transition in response to an optical or electrical stimulus; GST may therefore have applications in tunable photonic devices and optoelectronic circuits. In this progress article, we outline recent studies of GST and discuss its advantages and possible applications in reconfigurable metadevices. We also discuss outlooks for integration of GST in active nanophotonic metadevices. PMID:28878196

  3. Performance evaluation of a high power DC-DC boost converter for PV applications using SiC power devices

    Science.gov (United States)

    Almasoudi, Fahad M.; Alatawi, Khaled S.; Matin, Mohammad

    2016-09-01

    The development of Wide band gap (WBG) power devices has been attracted by many commercial companies to be available in the market because of their enormous advantages over the traditional Si power devices. An example of WBG material is SiC, which offers a number of advantages over Si material. For example, SiC has the ability of blocking higher voltages, reducing switching and conduction losses and supports high switching frequency. Consequently, SiC power devices have become the affordable choice for high frequency and power application. The goal of this paper is to study the performance of 4.5 kW, 200 kHz, 600V DC-DC boost converter operating in continuous conduction mode (CCM) for PV applications. The switching behavior and turn on and turn off losses of different switching power devices such as SiC MOSFET, SiC normally ON JFET and Si MOSFET are investigated and analyzed. Moreover, a detailed comparison is provided to show the overall efficiency of the DC-DC boost converter with different switching power devices. It is found that the efficiency of SiC power switching devices are higher than the efficiency of Si-based switching devices due to low switching and conduction losses when operating at high frequencies. According to the result, the performance of SiC switching power devices dominate the conventional Si power devices in terms of low losses, high efficiency and high power density. Accordingly, SiC power switching devices are more appropriate for PV applications where a converter of smaller size with high efficiency, and cost effective is required.

  4. A checking device for pipes in which a high pressure fluid is circulated

    International Nuclear Information System (INIS)

    Bauerle, R.D.; Pitt, W.A.; White, M.A.

    1974-01-01

    A checking device for restricting the movements of a pipe in which a high pressure fluid is circulated, should said pipe happen to be ruptured. That device comprises a U-shaped checking, or retaining bar surrounding the pipe, and slightly spaced therefrom at each end of said bar a support member fixed to a frame member of the steam generator and an articulated connection between each of said ends and its respective support-member. That device can be applied to nuclear steam boilers [fr

  5. In phantom calibration of a high dose rate remote afterloading device

    International Nuclear Information System (INIS)

    Alfonso, R.; Tolede, P.; Pich, V.

    1995-01-01

    The high dose-rate (HDR) brachytherapy in Cuba is based on soviet made devices type AGAT-V. In order to calibration one of these for clinical use a method based of the different measurement of absorbed dose at the reference point B in a paraffin phantom was developed. The results of the calibration are shown. From these results an analysis was made of the effective doses to prescription point a considering the Lineal-Quadratic model. The clinical results by using the AGAT-V device are displayed in a comparative way

  6. Electrical measuring device for a high temperature reactor

    International Nuclear Information System (INIS)

    Elter, C.; Handel, H.; Schoening, J.; Schmitt, H.

    1982-01-01

    The device for measuring the low or high neutron flux during start-up or at load is accommodated in an armoured guide tube projecting into the floor. A gas-tight capsule is formed as the measuring column with outer dome with a lid solidly connected by a flange to the armoured tube situated on the side wall of the concrete reactor vessel, together with the armoured guide tube. Two shielding shutters prevent the passage of radiation through the armoured tube. (DG) [de

  7. Development of high impedance measurement system for water leakage detection in implantable neuroprosthetic devices.

    Science.gov (United States)

    Yousif, Aziz; Kelly, Shawn K

    2016-08-01

    There has been a push for a greater number of channels in implantable neuroprosthetic devices; but, that number has largely been limited by current hermetic packaging technology. Microfabricated packaging is becoming reality, but a standard testing system is needed to prepare these devices for clinical trials. Impedance measurements of electrodes built into the packaging layers may give an early warning of device failure and predict device lifetime. Because the impedance magnitudes of such devices can be on the order of gigaohms, a versatile system was designed to accommodate ultra-high impedances and allow future integrated circuit implementation in current neural prosthetic technologies. Here we present the circuitry, control software, and preliminary testing results of our designed system.

  8. Comparison of Conventional versus Steerable-Catheter Guided Coronary Sinus Lead Positioning in Patients Undergoing Cardiac Resynchronization Device Implantation.

    Directory of Open Access Journals (Sweden)

    Fikret Er

    Full Text Available The aim of this study was to compare conventional versus steerable catheter guided coronary sinus (CS cannulation in patients with advanced heart failure undergoing cardiac resynchronization therapy (CRT.Steerable catheter guided coronary sinus cannulation could reduce fluoroscopy time and contrast medium use during CRT implantation.176 consecutive patients with ischemic and non-ischemic heart failure undergoing CRT implantation from January 2008 to December 2012 at the University Hospital of Cologne were identified. During the study period two concurrent CS cannulation techniques were used: standard CS cannulation technique (standard-group, n = 113 and CS cannulation using a steerable electrophysiology (EP catheter (EPCath-group, n = 63. Propensity-score matched pairs of conventional and EP-catheter guided CS cannulation made up the study population (n = 59 pairs. Primary endpoints were total fluoroscopy time and contrast medium amount used during procedure.The total fluoroscopy time was 30.9 min (interquartile range (IQR, 19.9-44.0 min in the standard-group and 23.4 min (IQR, 14.2-34-2 min in the EPCath-group (p = 0.011. More contrast medium was used in the standard-group (60.0 ml, IQR, 30.0-100 ml compared to 25.0 ml (IQR, 20.0-50.0 ml in the EPCath-group (P<0.001.Use of steerable EP catheter was associated with significant reduction of fluoroscopy time and contrast medium use in patients undergoing CRT implantation.

  9. Time–energy high-dimensional one-side device-independent quantum key distribution

    International Nuclear Information System (INIS)

    Bao Hai-Ze; Bao Wan-Su; Wang Yang; Chen Rui-Ke; Ma Hong-Xin; Zhou Chun; Li Hong-Wei

    2017-01-01

    Compared with full device-independent quantum key distribution (DI-QKD), one-side device-independent QKD (1sDI-QKD) needs fewer requirements, which is much easier to meet. In this paper, by applying recently developed novel time–energy entropic uncertainty relations, we present a time–energy high-dimensional one-side device-independent quantum key distribution (HD-QKD) and provide the security proof against coherent attacks. Besides, we connect the security with the quantum steering. By numerical simulation, we obtain the secret key rate for Alice’s different detection efficiencies. The results show that our protocol can performance much better than the original 1sDI-QKD. Furthermore, we clarify the relation among the secret key rate, Alice’s detection efficiency, and the dispersion coefficient. Finally, we simply analyze its performance in the optical fiber channel. (paper)

  10. A pragmatic multi-centre randomised controlled trial of fluid loading and level of dependency in high-risk surgical patients undergoing major elective surgery: trial protocol

    Directory of Open Access Journals (Sweden)

    Norrie John

    2010-04-01

    Full Text Available Abstract Background Patients undergoing major elective or urgent surgery are at high risk of death or significant morbidity. Measures to reduce this morbidity and mortality include pre-operative optimisation and use of higher levels of dependency care after surgery. We propose a pragmatic multi-centre randomised controlled trial of level of dependency and pre-operative fluid therapy in high-risk surgical patients undergoing major elective surgery. Methods/Design A multi-centre randomised controlled trial with a 2 * 2 factorial design. The first randomisation is to pre-operative fluid therapy or standard regimen and the second randomisation is to routine intensive care versus high dependency care during the early post-operative period. We intend to recruit 204 patients undergoing major elective and urgent abdominal and thoraco-abdominal surgery who fulfil high-risk surgical criteria. The primary outcome for the comparison of level of care is cost-effectiveness at six months and for the comparison of fluid optimisation is the number of hospital days after surgery. Discussion We believe that the results of this study will be invaluable in determining the future care and clinical resource utilisation for this group of patients and thus will have a major impact on clinical practice. Trial Registration Trial registration number - ISRCTN32188676

  11. First wall of thermonuclear device

    International Nuclear Information System (INIS)

    Miki, Nobuharu.

    1992-01-01

    In a first wall of a thermonuclear device, armour tiles are metallurgically bonded to a support substrate only for the narrow area of the central portion thereof, while bonded by metallurgical bonding with cooling tubes of low mechanical toughness, separated from each other in other regions. Since the bonding area with the support substrate of great mechanical rigidity is limited to the narrow region at the central portion of the armour tiles, cracking are scarcely caused at the end portion of the bonding surface. In other regions, since cooling tubes of low mechanical rigidity are bonded metallurgically, they can be sufficiently withstand to high thermal load. That is, even if the armour tiles are deformed while undergoing thermal load from plasmas, since the cooling tubes absorb it, there is no worry of damaging the metallurgically bonded face. Since the cooling tubes are bonded directly to the armour tiles, they absorb the heat of the armour tiles efficiently. (N.H.)

  12. Highly efficient white organic light-emitting devices consisting of undoped ultrathin yellow phosphorescent layer

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Shengqiang [State Key Laboratory of Electronic Thin Films and Integrated Devices, School of Optoelectronic Information, University of Electronic Science and Technology of China (UESTC), Chengdu 610054 (China); Yu, Junsheng, E-mail: jsyu@uestc.edu.cn [State Key Laboratory of Electronic Thin Films and Integrated Devices, School of Optoelectronic Information, University of Electronic Science and Technology of China (UESTC), Chengdu 610054 (China); Ma, Zhu; Zhao, Juan [State Key Laboratory of Electronic Thin Films and Integrated Devices, School of Optoelectronic Information, University of Electronic Science and Technology of China (UESTC), Chengdu 610054 (China)

    2013-02-15

    High-efficiency white organic light-emitting devices (WOLEDs) based on an undoped ultrathin yellow light-emitting layer and a doped blue light-emitting layer were demonstrated. While the thickness of blue light-emitting layer, formed by doping a charge-trapping phosphor, iridium(III) bis(4 Prime ,6 Prime -difluorophenylpyridinato)tetrakis(1-pyrazolyl)borate (FIr6) in a wide bandgap host, was kept constant, the thickness of neat yellow emissive layer of novel phosphorescent material, bis[2-(4-tertbutylphenyl)benzothiazolato-N,C{sup 2 Prime }]iridium (acetylacetonate) [(t-bt){sub 2}Ir(acac)] was varied to optimize the device performance. The optimized device exhibited maximum luminance, current efficiency and power efficiency of 24,000 cd/m{sup 2} (at 15.2 V), 79.0 cd/A (at 1550 cd/m{sup 2}) and 40.5 lm/W (at 1000 cd/m{sup 2}), respectively. Besides, the white-light emission covered a wide range of visible spectrum, and the Commission Internationale de l'Eclairage coordinates were (0.32, 0.38) with a color temperature of 5800 K at 8 V. Moreover, high external quantum efficiency was also obtained in the high-efficiency WOLEDs. The performance enhancement was attributed to the proper thickness of (t-bt){sub 2}Ir(acac) layer that enabled adequate current density and enough phosphorescent dye to trap electrons. - Highlights: Black-Right-Pointing-Pointer Highly efficient WOLEDs based on two complementary layers were fabricated. Black-Right-Pointing-Pointer The yellow emissive layer was formed by utilizing undoping system. Black-Right-Pointing-Pointer The blue emissive layer was made by host-guest doping system. Black-Right-Pointing-Pointer The thickness of the yellow emissive layer was varied to make device optimization. Black-Right-Pointing-Pointer The optimized device achieved high power efficiency of 40.5 lm/W.

  13. Investigation of structural and electrical properties on substrate material for high frequency metal-oxide-semiconductor (MOS) devices

    Science.gov (United States)

    Kumar, M.; Yang, Sung-Hyun; Janardhan Reddy, K.; JagadeeshChandra, S. V.

    2017-04-01

    Hafnium oxide (HfO2) thin films were grown on cleaned P-type Ge and Si substrates by using atomic layer deposition technique (ALD) with thickness of 8 nm. The composition analysis of as-deposited and annealed HfO2 films was characterized by XPS, further electrical measurements; we fabricated the metal-oxide-semiconductor (MOS) devices with Pt electrode. Post deposition annealing in O2 ambient at 500 °C for 30 min was carried out on both Ge and Si devices. Capacitance-voltage (C-V) and conductance-voltage (G-V) curves measured at 1 MHz. The Ge MOS devices showed improved interfacial and electrical properties, high dielectric constant (~19), smaller EOT value (0.7 nm), and smaller D it value as Si MOS devices. The C-V curves shown significantly high accumulation capacitance values from Ge devices, relatively when compare with the Si MOS devices before and after annealing. It could be due to the presence of very thin interfacial layer at HfO2/Ge stacks than HfO2/Si stacks conformed by the HRTEM images. Besides, from current-voltage (I-V) curves of the Ge devices exhibited similar leakage current as Si devices. Therefore, Ge might be a reliable substrate material for structural, electrical and high frequency applications.

  14. High-throughput, temperature-controlled microchannel acoustophoresis device made with rapid prototyping

    DEFF Research Database (Denmark)

    Adams, Jonathan D; Ebbesen, Christian L.; Barnkob, Rune

    2012-01-01

    -slide format using low-cost, rapid-prototyping techniques. This high-throughput acoustophoresis chip (HTAC) utilizes a temperature-stabilized, standing ultrasonic wave, which imposes differential acoustic radiation forces that can separate particles according to size, density and compressibility. The device...

  15. Flexible, highly graphitized carbon aerogels based on bacterial cellulose/lignin: Catalyst-free synthesis and its application in energy storage devices

    KAUST Repository

    Xu, Xuezhu

    2015-04-15

    Currently, most carbon aerogels are based on carbon nanotubes (CNTs) or graphene, which are produced through a catalyst-assisted chemical vapor deposition method. Biomass based organic aerogels and carbon aerogels, featuring low cost, high scalability, and small environmental footprint, represent an important new research direction in (carbon) aerogel development. Cellulose and lignin are the two most abundant natural polymers in the world, and the aerogels based on them are very promising. Classic silicon aerogels and available organic resorcinol-formaldehyde (RF) or lignin-resorcinol-formaldehyde (LRF) aerogels are brittle and fragile; toughening of the aerogels is highly desired to expand their applications. This study reports the first attempt to toughen the intrinsically brittle LRF aerogel and carbon aerogel using bacterial cellulose. The facile process is catalyst-free and cost-effective. The toughened carbon aerogels, consisting of blackberry-like, core-shell structured, and highly graphitized carbon nanofibers, are able to undergo at least 20% reversible compressive deformation. Due to their unique nanostructure and large mesopore population, the carbon materials exhibit an areal capacitance higher than most of the reported values in the literature. This property makes them suitable candidates for flexible solid-state energy storage devices. Besides energy storage, the conductive interconnected nanoporous structure can also find applications in oil/water separation, catalyst supports, sensors, and so forth. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  16. Safety syringes and anti-needlestick devices in orthopaedic surgery.

    Science.gov (United States)

    Sibbitt, Wilmer L; Band, Philip A; Kettwich, Lawrence G; Sibbitt, Cristina R; Sibbitt, Lori J; Bankhurst, Arthur D

    2011-09-07

    The American Academy of Orthopaedic Surgery (AAOS), The Joint Commission, the Occupational Safety and Health Administration (OSHA), and the Needlestick Safety and Prevention Act encourage the integration of safety-engineered devices to prevent needlestick injuries to health-care workers and patients. We hypothesized that safety syringes and needles could be used in outpatient orthopaedic injection and aspiration procedures. The study investigated the orthopaedic uses and procedural idiosyncrasies of safety-engineered devices, including (1) four safety needles (Eclipse, SafetyGlide, SurGuard, and Magellan), (2) a mechanical safety syringe (RPD), (3) two automatic retractable syringes (Integra, VanishPoint), (4) three manual retractable syringes (Procedur-SF, Baksnap, Invirosnap), and (5) three shielded syringes (Safety-Lok, Monoject, and Digitally Activated Shielded [DAS] Syringe). The devices were first tested ex vivo, and then 1300 devices were used for 425 subjects undergoing outpatient arthrocentesis, intra-articular injections, local anesthesia, aspiration biopsy, and ultrasound-guided procedures. During the clinical observation, there were no accidental needlesticks (0 needlesticks per 1300 devices). Safety needles could be successfully used on a Luer syringe but were limited to ≤1.5 in (≤3.81 cm) in length and the shield could interfere with sonography. The mechanical safety syringes functioned well in all orthopaedic procedures. Automatic retractable syringes were too small for arthrocentesis of the knee, and the plunger blew out and prematurely collapsed with high-pressure injections. The manual retractable syringes and shielded syringes could be used with conventional needles for most orthopaedic procedures. The most effective and reliable safety devices for orthopaedic syringe procedures are shielded safety needles, mechanical syringes, manual retractable syringes, and shielded syringes, but not automatic retractable syringes. Even when adopting

  17. Characterization of Radiation Hardened Bipolar Linear Devices for High Total Dose Missions

    Science.gov (United States)

    McClure, Steven S.; Harris, Richard D.; Rax, Bernard G.; Thorbourn, Dennis O.

    2012-01-01

    Radiation hardened linear devices are characterized for performance in combined total dose and displacement damage environments for a mission scenario with a high radiation level. Performance at low and high dose rate for both biased and unbiased conditions is compared and the impact to hardness assurance methodology is discussed.

  18. Numerical study of the Columbia high-beta device: Torus-II

    Energy Technology Data Exchange (ETDEWEB)

    Izzo, R.

    1981-01-01

    The ionization, heating and subsequent long-time-scale behavior of the helium plasma in the Columbia fusion device, Torus-II, is studied. The purpose of this work is to perform numerical simulations while maintaining a high level of interaction with experimentalists. The device is operated as a toroidal z-pinch to prepare the gas for heating. This ionization of helium is studied using a zero-dimensional, two-fluid code. It is essentially an energy balance calculation that follows the development of the various charge states of the helium and any impurities (primarily silicon and oxygen) that are present. The code is an atomic physics model of Torus-II. In addition to ionization, we include three-body and radiative recombination processes.

  19. Numerical study of the Columbia high-beta device: Torus-II

    International Nuclear Information System (INIS)

    Izzo, R.

    1981-01-01

    The ionization, heating and subsequent long-time-scale behavior of the helium plasma in the Columbia fusion device, Torus-II, is studied. The purpose of this work is to perform numerical simulations while maintaining a high level of interaction with experimentalists. The device is operated as a toroidal z-pinch to prepare the gas for heating. This ionization of helium is studied using a zero-dimensional, two-fluid code. It is essentially an energy balance calculation that follows the development of the various charge states of the helium and any impurities (primarily silicon and oxygen) that are present. The code is an atomic physics model of Torus-II. In addition to ionization, we include three-body and radiative recombination processes

  20. Outcomes of implementation of enhanced goal directed therapy in high-risk patients undergoing abdominal surgery

    Directory of Open Access Journals (Sweden)

    Lakshmi Kumar

    2015-01-01

    Full Text Available Background and Aims: Advanced monitoring targeting haemodynamic and oxygenation variables can improve outcomes of surgery in high-risk patients. We aimed to assess the impact of goal directed therapy (GDT targeting cardiac index (CI and oxygen extraction ratio (O 2 ER on outcomes of high-risk patients undergoing abdominal surgery. Methods: In a prospective randomised trial, forty patients (American Society of Anaesthesiologists II and III undergoing major abdominal surgeries were randomised into two groups. In-Group A mean arterial pressure ≥ 65 mmHg, central venous pressure ≥ 8-10 mmHg, urine output ≥ 0.5 mL/kg/h and central venous oxygen saturation ≥ 70% were targeted intra-operatively and 12 h postoperatively. In-Group-B (enhanced GDT, in addition to the monitoring in-Group-A, CI ≥ 2.5 L/min/m 2 and O 2 ER ≤ 27% were targeted. The end-points were lactate levels and base deficit during and after surgery. The secondary end points were length of Intensive Care Unit (ICU and hospital stay and postoperative complications. Wilcoxon Mann Whitney and Chi-square tests were used for statistical assessment. Results: Lactate levels postoperatively at 4 and 8 h were lower in-Group-B (P < 0.05. The mean base deficit at 3, 4, 5 and 6 h intra-operatively and postoperatively after 4, 8 and 12 h were lower in-Group-B (P < 0.05. There were no significant differences in ICU stay (2.10 ± 1.52 vs. 2.90 ± 2.51 days or hospital stay (10.85 + 4.39 vs. 13.35 + 6.77 days between Group A and B. Conclusions: Implementation of enhanced GDT targeting CI and OER was associated with improved tissue oxygenation.

  1. High Prevalence of Nonalcoholic Fatty Liver Disease in Adolescents Undergoing Bariatric Surgery.

    Science.gov (United States)

    Xanthakos, Stavra A; Jenkins, Todd M; Kleiner, David E; Boyce, Tawny W; Mourya, Reena; Karns, Rebekah; Brandt, Mary L; Harmon, Carroll M; Helmrath, Michael A; Michalsky, Marc P; Courcoulas, Anita P; Zeller, Meg H; Inge, Thomas H

    2015-09-01

    Little is known about the prevalence of nonalcoholic fatty liver disease (NAFLD) among severely obese adolescents or factors that determine its development. We investigated the prevalence of NAFLD in a multicenter cohort of adolescents undergoing bariatric surgery and the factors associated with it. We enrolled 242 adolescents undergoing bariatric surgery between March 2007 and February 2012 at 5 tertiary care centers into a multicenter, prospective observational cohort study. Intraoperative core liver biopsies were collected from 165 subjects; 17 were excluded because of insufficient liver tissue or use of hepatotoxic medications, so 148 remained in the study (mean age, 16.8 ± 1.6 years; median body mass index = 52 kg/m(2)). Liver tissues were analyzed by histology using validated criteria. Hepatic gene expression was analyzed in 67 samples. NAFLD was present in 59% of this predominantly female (72%), white (68%), non-Hispanic (91%) cohort. Of subjects with NAFLD, 24% had borderline and 10% had definite nonalcoholic steatohepatitis (NASH). Mild fibrosis (stage 2 or lower) was observed in 18% of liver biopsies and stage 3 was observed in 0.7%, but cirrhosis was not detected. Dyslipidemia was present in 78% of subjects, hypertension in 44%, and diabetes in 14%. More severe NAFLD was associated with increasing levels of alanine aminotransferase, fasting glucose level, hypertension (each P adolescents undergoing bariatric surgery in this cohort had NAFLD, yet the prevalence of severe or fibrotic NASH was low. Increasing severity of NAFLD was associated with level of alanine aminotransferase and cardiometabolic risk factors, but not body mass index. Based on gene expression analysis, borderline and definite NASH were associated with abnormal immune function, intestinal cholesterol absorption, and lipid metabolism. Copyright © 2015 AGA Institute. Published by Elsevier Inc. All rights reserved.

  2. Per-Pixel Coded Exposure for High-Speed and High-Resolution Imaging Using a Digital Micromirror Device Camera

    Directory of Open Access Journals (Sweden)

    Wei Feng

    2016-03-01

    Full Text Available High-speed photography is an important tool for studying rapid physical phenomena. However, low-frame-rate CCD (charge coupled device or CMOS (complementary metal oxide semiconductor camera cannot effectively capture the rapid phenomena with high-speed and high-resolution. In this paper, we incorporate the hardware restrictions of existing image sensors, design the sampling functions, and implement a hardware prototype with a digital micromirror device (DMD camera in which spatial and temporal information can be flexibly modulated. Combined with the optical model of DMD camera, we theoretically analyze the per-pixel coded exposure and propose a three-element median quicksort method to increase the temporal resolution of the imaging system. Theoretically, this approach can rapidly increase the temporal resolution several, or even hundreds, of times without increasing bandwidth requirements of the camera. We demonstrate the effectiveness of our method via extensive examples and achieve 100 fps (frames per second gain in temporal resolution by using a 25 fps camera.

  3. Evaluation of the acute adverse reaction of contrast medium with high and moderate iodine concentration in patients undergoing computed tomography

    International Nuclear Information System (INIS)

    Nagamoto, Masashi; Gomi, Tatsuya; Terada, Hitoshi; Terada, Shigehiko; Kohda, Eiichi

    2006-01-01

    The aim of this prospective study was to evaluate and compare acute adverse reactions between contrast medium containing moderate and high concentrations of iodine in patients undergoing computed tomography (CT). A total of 945 patients undergoing enhanced CT were randomly assigned to receive one of two doses of contrast medium. We then prospectively investigated the incidence of adverse reactions. Iopamidol was used as the contrast medium, with a high concentration of 370 mgI/ml and a moderate concentration of 300 mgI/ml. The frequency of adverse reactions, such as pain at the injection site and heat sensation, were determined. Acute adverse reactions were observed in 2.4% (11/458) of the moderate-concentration group compared to 3.11% (15/482) of the high-concentration group; there was no significant difference in incidence between the two groups. Most adverse reactions were mild, and there was no significant difference in severity. One patient in the high-concentration group was seen to have a moderate adverse reaction. No correlation existed between the incidence of adverse reactions and patient characteristics such as sex, age, weight, flow amount, and flow rate. The incidence of pain was not significantly different between the two groups. In contrast, the incidence of heat sensation was significantly higher in the high-concentration group. The incidence and severity of acute adverse reactions were not significantly different between the two groups, and there were no severe adverse reactions in either group. (author)

  4. Hollow-cathode electrode for high-power, high-pressure discharge devices

    Science.gov (United States)

    Chang, J.J.; Alger, T.W.

    1995-08-22

    Several different cold cathode configurations are disclosed for a gas discharge device each having a plurality of grooves of selected spacing, depth and width to improve the emission of electrons in a gas discharge device. Each of the cold cathode configurations can be machined from a single piece of a selected material. Several of the configurations can be assembled with individual elements which is easily seen from the various figures. 8 figs.

  5. Safeguards of basic protection devices, high-protection devices, full-protection devices and school X-ray devices. Guideline for manufacturer and evaluating experts, rev. 1.0; Sicherheitsvorrichtungen von Basisschutzgeraeten, Hochschutzgeraeten, Vollschutzgeraeten und Schulroentgeneinrichtungen. Anforderungen fuer die Bauartpruefung nach der Roentgenverordnung. Leitfaden fuer Hersteller und Gutachter Rev. 1.0

    Energy Technology Data Exchange (ETDEWEB)

    Dombrowski, Harald; Grottker, Ulrich; Pullner, Bjoern; Roettger, Annette; Zwiener, Roland

    2017-07-15

    This report describes the PTB requirements for engineered safeguards of basic-protection devices, high-protection devices, full-protection devices and school X-ray devices within the framework of type tests according to the German X-ray Ordinance. It contains detailed requirements for the hard- and software to ensure the required safety level. Especially manufacturers and evaluators of such X-ray tube assemblies are addressed.

  6. Application of high-temperature superconducting coil for internal ring devices

    Energy Technology Data Exchange (ETDEWEB)

    Ogawa, Yuichi [High Temperature Plasma Center, University of Tokyo, 5-1-5 Kashiwanoha, Kashiwa, Chiba 277-8568 (Japan)]. E-mail: ogawa@ppl.k.u-tokyo.ac.jp; Morikawa, Junji [High Temperature Plasma Center, University of Tokyo, 5-1-5 Kashiwanoha, Kashiwa, Chiba 277-8568 (Japan); Mito, Toshiyuki [National Institute for Fusion Science, Oroshi, Toki, Gifu 509-5292 (Japan); Yanagi, Nagato [National Institute for Fusion Science, Oroshi, Toki, Gifu 509-5292 (Japan); Iwakuma, Masataka [Kyushu University, 6-10-1 Hakozaki, Higashi-ku, Fukuoka 812-8581 (Japan)

    2006-11-15

    A high-temperature superconducting (HTS) coil is applied for plasma confinement devices, where plasma is confined with a magnetic field of a floating HTS coil. The internal coil device mini-RT with a BSCCO tape has been constructed, in which the coil major radius and magnetomotive force are 0.15 m and 50 kA, respectively. The coil is cooled to 20 K with a helium gas by using a demountable transfer tube and check valve system. The coil current is directly excited by the external power supply with demountable electrodes. To reduce the heat load, the electrodes were cooled with liquid nitrogen. The levitation experiment of the HTS coil has been carried out. The position of the HTS coil is measured by laser sensors, and is feedback-controlled with the levitation coil current. We have succeeded in levitating the HTS coil during 1 h with accuracy of less than 20 {mu}m. The magnetic field strength near the internal coil is around 0.1 T, and a radio-frequency wave of 2.45 GHz is applied for the plasma production. At the floating condition of the HTS coil, a high-density plasma with more than 10{sup 17} m{sup -3}, which is higher than the cut-off density of a 2.45 GHz microwave, has been produced. A new device RT-1 with a major radius of 0.25 m and a magnetomotive force of 250 kA is under construction, and a persistent current has been demonstrated. The feasibility on YBCO tape is briefly discussed.

  7. A high throughput mechanical screening device for cartilage tissue engineering.

    Science.gov (United States)

    Mohanraj, Bhavana; Hou, Chieh; Meloni, Gregory R; Cosgrove, Brian D; Dodge, George R; Mauck, Robert L

    2014-06-27

    Articular cartilage enables efficient and near-frictionless load transmission, but suffers from poor inherent healing capacity. As such, cartilage tissue engineering strategies have focused on mimicking both compositional and mechanical properties of native tissue in order to provide effective repair materials for the treatment of damaged or degenerated joint surfaces. However, given the large number design parameters available (e.g. cell sources, scaffold designs, and growth factors), it is difficult to conduct combinatorial experiments of engineered cartilage. This is particularly exacerbated when mechanical properties are a primary outcome, given the long time required for testing of individual samples. High throughput screening is utilized widely in the pharmaceutical industry to rapidly and cost-effectively assess the effects of thousands of compounds for therapeutic discovery. Here we adapted this approach to develop a high throughput mechanical screening (HTMS) system capable of measuring the mechanical properties of up to 48 materials simultaneously. The HTMS device was validated by testing various biomaterials and engineered cartilage constructs and by comparing the HTMS results to those derived from conventional single sample compression tests. Further evaluation showed that the HTMS system was capable of distinguishing and identifying 'hits', or factors that influence the degree of tissue maturation. Future iterations of this device will focus on reducing data variability, increasing force sensitivity and range, as well as scaling-up to even larger (96-well) formats. This HTMS device provides a novel tool for cartilage tissue engineering, freeing experimental design from the limitations of mechanical testing throughput. © 2013 Published by Elsevier Ltd.

  8. Reactor scram device for FBR type reactor

    International Nuclear Information System (INIS)

    Kumasaka, Katsuyuki; Arashida, Genji; Itooka, Satoshi.

    1991-01-01

    In a control rod attaching structure in a reactor scram device of an FBR type reactor, an anti-rising mechanism proposed so far against external upward force upon occurrence of earthquakes relies on the engagement of a mechanical structure but temperature condition is not taken into consideration. Then, in the present invention, a material having curie temperature characteristics and which exhibits ferromagnetism only under low temperature condition and a magnet device are disposed to one of a movable control rod and a portion secured to the reactor. Alternatively, a bimetal member or a shape memory alloy which actuates to fix to the mating member only under low temperature condition is secured. The fixing device is adapted to operate so as to secure the control rods when the low temperature state is caused depending on the temperature condition. With such a constitution, when the control rods are separated from a driving device, they are prevented from rising even if they undergo external upward force due to earthquakes and so on, which can improve the reactor safety. (N.H.)

  9. Determining the mode of high voltage breakdowns in vacuum devices

    International Nuclear Information System (INIS)

    Miller, H.C.; Furno, E.J.; Sturtz, J.P.

    1980-01-01

    Devices were constructed which were essentially vacuum diodes equipped with windows allowing observation of high voltage breakdowns. The waveform of the applied voltage was photographed, and the x-ray output was monitored to investigate electrical breakdown in these vacuum diodes. Results indicate that breakdowns may be divided into two types: (1) vacuum (interelectrode) breakdown - characterized by a diffuse moderately bright discharge, a relative slow and smooth voltage collapse, and a large burst of x-rays, and (2) surface (insulator) flashover - characterized by a bright discharge with a very bright filamentary core, a relatively fast and noisy voltage collapse and no x-ray burst. Useful information concerning the type of breakdown in a vacuum device can be obtained by monitoring the voltage (current) waveform and the x-ray output

  10. Travelling type monitoring and inspection device

    International Nuclear Information System (INIS)

    Ito, Takao; Maruki, Hideaki.

    1994-01-01

    The present invention sufficiently ensures video output images even if lenses of a television camera of a monitoring means are degraded to reduce the quantity of transmission light. That is, a light amount control mechanism capable of controlling the quantity of illumination light irradiated from an illumination device at an output level of a sensor of an inspection device main body. A test chart for measuring a luminance which is an output level of the sensor is disposed. During plant operation, the lenses of the television camera undergo influences of radioactivity and are degraded to reduce the quantity of transmission light on every periodical monitoring and inspection using a travelling type monitoring inspection device. In this case, the test chart disposed near the equipment to be monitored and inspected is caught by the television camera to measure a sensor output luminance. Then, the light amount control mechanism of the illumination device is controlled so as to provide a luminance which has been set at an initial stage of the plant inspection. With such procedures, video data of the objective equipment to be monitored and inspected can be obtained at a constant luminance during inspection. (I.S.)

  11. Highly efficient hybrid energy generator: coupled organic photovoltaic device and randomly oriented electrospun poly(vinylidene fluoride) nanofiber.

    Science.gov (United States)

    Park, Boongik; Lee, Kihwan; Park, Jongjin; Kim, Jongmin; Kim, Ohyun

    2013-03-01

    A hybrid architecture consisting of an inverted organic photovoltaic device and a randomly-oriented electrospun PVDF piezoelectric device was fabricated as a highly-efficient energy generator. It uses the inverted photovoltaic device with coupled electrospun PVDF nanofibers as tandem structure to convert solar and mechanical vibrations energy to electricity simultaneously or individually. The power conversion efficiency of the photovoltaic device was also significantly improved up to 4.72% by optimized processes such as intrinsic ZnO, MoO3 and active layer. A simple electrospinning method with the two electrode technique was adopted to achieve a high voltage of - 300 mV in PVDF piezoelectric fibers. Highly-efficient HEG using voltage adder circuit provides the conceptual possibility of realizing multi-functional energy generator whenever and wherever various energy sources are available.

  12. Polysilicon high frequency devices for large area electronics: Characterization, simulation and modeling

    Energy Technology Data Exchange (ETDEWEB)

    Botrel, J L [CEA-LETI 17, rue des Martyrs 38054 Grenoble (France); IMEP 23, rue des Martyrs 38016 Grenoble (France)], E-mail: jean-loius.botrel@cea.fr; Savry, O; Rozeau, O; Templier, F [CEA-LETI 17, rue des Martyrs 38054 Grenoble (France); Jomaah, J [IMEP 23, rue des Martyrs 38016 Grenoble (France)

    2007-07-16

    Laser Crystallised Polysilicon Thin Film Transistors have now sufficient good conduction properties to be used in high-frequency applications. In this work, we report the results for 5 {mu}m long polysilicon TFTs obtained at frequencies up to several hundred MHz for applications such as RFID tags or System-On-Panel. In order to investigate the device operation, DC and AC two-dimensional simulations of these devices in the Effective Medium framework have been performed. In the light of simulation results, the effects of carrier trapping and carrier transit on the device capacitances as a function of dimensions are analysed and compared. An equivalent small-signal circuit which accounts for the behaviour of these transistors in all regions of operation is proposed and a model for the most relevant elements of this circuit is presented. To validate our simulation results, scattering-parameters (S-parameters) measurements are performed for several structures such as multi-finger, serpentine and linear architectures and the most meaningful parameters will be given. Cut-off frequencies as high as 300 MHz and maximum oscillation frequencies of about 600 MHz have been extracted.

  13. High-efficiency red electroluminescent device based on multishelled InP quantum dots.

    Science.gov (United States)

    Jo, Jung-Ho; Kim, Jong-Hoon; Lee, Ki-Heon; Han, Chang-Yeol; Jang, Eun-Pyo; Do, Young Rag; Yang, Heesun

    2016-09-01

    We report on the synthesis of highly fluorescent red-emitting InP quantum dots (QDs) and their application to the fabrication of a high-efficiency QD-light-emitting diode (QLED). The core/shell heterostructure of the QDs is elaborately tailored toward a multishelled structure with a composition-gradient ZnSeS intermediate shell and an outer ZnS shell. Using the resulting InP/ZnSeS/ZnS QDs as an emitting layer, all-solution-processible red InP QLEDs are fabricated with a hybrid multilayered device structure having an organic hole transport layer (HTL) and an inorganic ZnO nanoparticle electron transport layer. Two HTLs of poly(9-vinlycarbazole) or poly[(9,9-dioctylfluorenyl-2,7-diyl)-co-(4,4'-(N-(4-sec-butylphenyl))diphenyl-amine), whose hole mobilities are different by at least three orders of magnitude, are individually applied for QLED fabrication and such HTL-dependent device performances are compared. Our best red device displays exceptional figures of merit such as a maximum luminance of 2849  cd/m2, a current efficiency of 4.2  cd/A, and an external quantum efficiency of 2.5%.

  14. High mobility AlGaN/GaN devices for β"−-dosimetry

    International Nuclear Information System (INIS)

    Schmid, Martin; Howgate, John; Ruehm, Werner; Thalhammer, Stefan

    2016-01-01

    There is a high demand in modern medical applications for dosimetry sensors with a small footprint allowing for unobtrusive or high spatial resolution detectors. To this end we characterize the sensoric response of radiation resistant high mobility AlGaN/GaN semiconductor devices when exposed to β"−-emitters. The samples were operated as a floating gate transistor, without a field effect gate electrode, thus excluding any spurious effects from β"−-particle interactions with a metallic surface covering. We demonstrate that the source–drain current is modulated in dependence on the kinetic energy of the incident β"−-particles. Here, the signal is shown to have a linear dependence on the absorbed energy calculated from Monte Carlo simulations. Additionally, a stable and reproducible sensor performance as a β"−-dose monitor is shown for individual radioisotopes. Our experimental findings and the characteristics of the AlGaN/GaN high mobility layered devices indicate their potential for future applications where small sensor size is necessary, like for instance brachytherapy.

  15. Atomic origin of high-temperature electron trapping in metal-oxide-semiconductor devices

    Energy Technology Data Exchange (ETDEWEB)

    Shen, Xiao, E-mail: xiao.shen@vanderbilt.edu [Department of Physics and Astronomy, Vanderbilt University, Nashville, Tennessee 37235 (United States); Dhar, Sarit [Department of Physics, Auburn University, Auburn, Alabama 36849 (United States); Pantelides, Sokrates T. [Department of Physics and Astronomy, Vanderbilt University, Nashville, Tennessee 37235 (United States); Department of Electrical Engineering and Computer Science, Vanderbilt University, Nashville, Tennessee 37235 (United States); Materials Science and Technology Division, Oak Ridge National Laboratory, Oak Ridge, Tennessee 37831 (United States)

    2015-04-06

    MOSFETs based on wide-band-gap semiconductors are suitable for operation at high temperature, at which additional atomic-scale processes that are benign at lower temperatures can get activated, resulting in device degradation. Recently, significant enhancement of electron trapping was observed under positive bias in SiC MOSFETs at temperatures higher than 150 °C. Here, we report first-principles calculations showing that the enhanced electron trapping is associated with thermally activated capturing of a second electron by an oxygen vacancy in SiO{sub 2} by which the vacancy transforms into a structure that comprises one Si dangling bond and a bond between a five-fold and a four-fold Si atoms. The results suggest a key role of oxygen vacancies and their structural reconfigurations in the reliability of high-temperature MOS devices.

  16. Nasal high flow therapy: a novel treatment rather than a more expensive oxygen device

    Directory of Open Access Journals (Sweden)

    Eleni Ischaki

    2017-09-01

    Full Text Available Nasal high flow is a promising novel oxygen delivery device, whose mechanisms of action offer some beneficial effects over conventional oxygen systems. The administration of a high flow of heated and humidified gas mixture promotes higher and more stable inspiratory oxygen fraction values, decreases anatomical dead space and generates a positive airway pressure that can reduce the work of breathing and enhance patient comfort and tolerance. Nasal high flow has been used as a prophylactic tool or as a treatment device mostly in patients with acute hypoxaemic respiratory failure, with the majority of studies showing positive results. Recently, its clinical indications have been expanded to post-extubated patients in intensive care or following surgery, for pre- and peri-oxygenation during intubation, during bronchoscopy, in immunocompromised patients and in patients with “do not intubate” status. In the present review, we differentiate studies that suggest an advantage (benefit from other studies that do not suggest an advantage (no benefit compared to conventional oxygen devices or noninvasive ventilation, and propose an algorithm in cases of nasal high flow application in patients with acute hypoxaemic respiratory failure of almost any cause.

  17. Migrational polarization in high-current density molten salt electrochemical devices

    Energy Technology Data Exchange (ETDEWEB)

    Braunstein, J.; Vallet, C.E.

    1977-01-01

    Electrochemical flux equations based on the thermodynamics of irreversible processes have been derived in terms of experimental transport coefficients for binary molten salt mixtures analogous to those proposed for high temperature batteries and fuel cells. The equations and some numerical solutions indicate steady state composition gradients of significant magnitude. The effects of migrational separation must be considered along with other melt properties in the characterization of electrode behavior, melt composition, operating temperatures and differences of phase stability, wettability and other physicochemical properties at positive and negative electrodes of high current density devices with mixed electrolytes.

  18. High-Tc superconductor quantum interference devices

    International Nuclear Information System (INIS)

    1991-01-01

    This patent describes a superconductive quantum interferometric device for sensing a characteristic of a magnetic field. It comprises a substrate having a surface, the substrate being selected from the group which consists of strontium titanate, aluminum oxide, sapphire, ZrO 2 and mixtures thereof; a coating of MgO on the surface of the substrate; two identical thin-strip films of a high-critical temperature superconductor on the coating, each of the films having a pair of mutually parallel arms in the form of superconductor strips extending toward and aligned with super conductor strips forming corresponding arms of the other thin-strip film, and a crossbar strip connecting the arms of each thin-strip film at right angles to the arms, the high-critical-temperature superconductor being selected from the group which consists of yttrium-barium-calcium-copper-oxides, bismuth-strontium-calcium-copper-oxides, thallium-barium-copper-oxides, thallium-barium-calcium-copper-oxides, barium oxide: potassium oxide: bismuth oxides, and calcium oxide: zinc oxide: iron oxides; and insulating films on the coating between corresponding free ends of the arms thin-strip films, the insulating films being composed of a material selected from the group which consists of silicon dioxide, silicon nitride, magnesium oxide and mixture thereof

  19. A new automatic design method to develop multilayer thin film devices for high power laser applications

    International Nuclear Information System (INIS)

    Sahoo, N.K.; Apparao, K.V.S.R.

    1992-01-01

    Optical thin film devices play a major role in many areas of frontier technology like development of various laser systems to the designing of complex and precision optical systems. Design and development of these devices are really challenging when they are meant for high power laser applications. In these cases besides desired optical characteristics, the devices are expected to satisfy a whole range of different needs like high damage threshold, durability etc. In the present work a novel completely automatic design method based on Modified Complex Method has been developed for designing of high power thin film devices. Unlike most of the other methods it does not need any suitable starting design. A quarterwave design is sufficient to start with. If required, it is capable of generating its own starting design. The computer code of the method is very simple to implement. This report discusses this novel automatic design method and presents various practicable output designs generated by it. The relative efficiency of the method along with other powerful methods has been presented while designing a broadband IR antireflection coating. The method is also incorporated with 2D and 3D electric field analysis programmes to produce high damage threshold designs. Some experimental devices developed using such designs are also presented in the report. (author). 36 refs., 41 figs

  20. Ultra-high-ohmic microstripline resistors for Coulomb blockade devices

    International Nuclear Information System (INIS)

    Lotkhov, Sergey V

    2013-01-01

    In this paper, we report on the fabrication and low-temperature characterization of ultra-high-ohmic microstripline resistors made of a thin film of weakly oxidized titanium. Nearly linear voltage–current characteristics were measured at temperatures down to T ∼ 20 mK for films with sheet resistivities as high as ∼7 kΩ, i.e. about an order of magnitude higher than our previous findings for weakly oxidized Cr. Our analysis indicates that such an improvement can help to create an advantageous high-impedance environment for different Coulomb blockade devices. Further properties of the Ti film addressed in this work show the promise of low-noise behavior of the resistors when applied in different realizations of the quantum standard of current. (paper)

  1. "Joint Workshop on High Confidence Medical Devices, Software, and Systems (HCMDSS) and Medical Device Plug-and-Play (MD PnP) Interoperability"

    National Research Council Canada - National Science Library

    Goldman, Julian M

    2008-01-01

    Partial support was requested from TATRC, with joint funding from NSF, for a joint workshop to bring together the synergistic efforts and communities of the High Confidence Medical Devices, Software, and Systems (HCMDSS...

  2. Percutaneous Transcatheter PDA Device Closure in Infancy

    International Nuclear Information System (INIS)

    Ullah, M.; Sultan, M.; Akhtar, K.; Sadiq, N.; Akbar, H.

    2014-01-01

    Objective: To evaluate the results and complications associated with transcatheter closure of patent ductus arteriosus (PDA) in infants. Study Design: Quasi-experimental study. Place and Duration of Study: Paediatric Cardiology Department of Armed Forces Institute of Cardiology / National Institute of Heart Diseases (AFIC/NIHD), Rawalpindi, from December 2010 to June 2012. Methodology: Infants undergoing transcatheter device closure of PDA were included. All patients were evaluated by experienced Paediatric Cardiologists with 2-D echocardiography and Doppler before the procedure. Success of closure and complications were recorded. Results: The age of patients varied from 05 - 12 months and 31 (56.4%) were females. Out of the 55 infants, 3 (5.4%) were not offered device closure after aortogram (two large tubular type ducts and one tiny duct, considered unsuitable for device closure); while in 50 (96.1%) patients out of remaining 52, the duct was successfully closed with transcatheter PDA device or coil. In one infant, device deployment resulted in acquired coarctation, necessitating device retrieval by Snare followed by surgical duct interruption and another patient had non-fatal cardiac arrest during device deployment leading to abandonment of procedure and subsequent successful surgical interruption. Local vascular complications occurred in 12 (21.8%) of cases and all were satisfactorily treated. Conclusion: Transcatheter device closure of PDA in infants was an effective procedure in the majority of cases; however, here were considerable number of local access site vascular complications. (author)

  3. Flexible semi-transparent silicon (100) fabric with high-k/metal gate devices

    KAUST Repository

    Rojas, Jhonathan Prieto; Hussain, Muhammad Mustafa

    2013-01-01

    (100) wafers and then released as continuous, mechanically flexible, optically semi-transparent and high thermal budget compatible silicon fabric with devices. This is the first ever demonstration with this set of materials which allows full degree

  4. Levosimendan in Patients with Left Ventricular Dysfunction Undergoing Cardiac Surgery.

    Science.gov (United States)

    Mehta, Rajendra H; Leimberger, Jeffrey D; van Diepen, Sean; Meza, James; Wang, Alice; Jankowich, Rachael; Harrison, Robert W; Hay, Douglas; Fremes, Stephen; Duncan, Andra; Soltesz, Edward G; Luber, John; Park, Soon; Argenziano, Michael; Murphy, Edward; Marcel, Randy; Kalavrouziotis, Dimitri; Nagpal, Dave; Bozinovski, John; Toller, Wolfgang; Heringlake, Matthias; Goodman, Shaun G; Levy, Jerrold H; Harrington, Robert A; Anstrom, Kevin J; Alexander, John H

    2017-05-25

    Levosimendan is an inotropic agent that has been shown in small studies to prevent or treat the low cardiac output syndrome after cardiac surgery. In a multicenter, randomized, placebo-controlled, phase 3 trial, we evaluated the efficacy and safety of levosimendan in patients with a left ventricular ejection fraction of 35% or less who were undergoing cardiac surgery with the use of cardiopulmonary bypass. Patients were randomly assigned to receive either intravenous levosimendan (at a dose of 0.2 μg per kilogram of body weight per minute for 1 hour, followed by a dose of 0.1 μg per kilogram per minute for 23 hours) or placebo, with the infusion started before surgery. The two primary end points were a four-component composite of death through day 30, renal-replacement therapy through day 30, perioperative myocardial infarction through day 5, or use of a mechanical cardiac assist device through day 5; and a two-component composite of death through day 30 or use of a mechanical cardiac assist device through day 5. A total of 882 patients underwent randomization, 849 of whom received levosimendan or placebo and were included in the modified intention-to-treat population. The four-component primary end point occurred in 105 of 428 patients (24.5%) assigned to receive levosimendan and in 103 of 421 (24.5%) assigned to receive placebo (adjusted odds ratio, 1.00; 99% confidence interval [CI], 0.66 to 1.54; P=0.98). The two-component primary end point occurred in 56 patients (13.1%) assigned to receive levosimendan and in 48 (11.4%) assigned to receive placebo (adjusted odds ratio, 1.18; 96% CI, 0.76 to 1.82; P=0.45). The rate of adverse events did not differ significantly between the two groups. Prophylactic levosimendan did not result in a rate of the short-term composite end point of death, renal-replacement therapy, perioperative myocardial infarction, or use of a mechanical cardiac assist device that was lower than the rate with placebo among patients with a

  5. Influence of the ambient temperature on the cooling efficiency of the high performance cooling device with thermosiphon effect

    Science.gov (United States)

    Nemec, Patrik; Malcho, Milan

    2018-06-01

    This work deal with experimental measurement and calculation cooling efficiency of the cooling device working with a heat pipe technology. The referred device in the article is cooling device capable transfer high heat fluxes from electric elements to the surrounding. The work contain description, working principle and construction of cooling device. The main factor affected the dissipation of high heat flux from electronic elements through the cooling device to the surrounding is condenser construction, its capacity and option of heat removal. Experimental part describe the measuring method cooling efficiency of the cooling device depending on ambient temperature in range -20 to 40°C and at heat load of electronic components 750 W. Measured results are compared with results calculation based on physical phenomena of boiling, condensation and natural convection heat transfer.

  6. The effects of electrode cleaning and conditioning on the performance of high-energy, pulsed-power devices

    Energy Technology Data Exchange (ETDEWEB)

    Cuneo, M.E.

    1998-09-01

    High-energy pulsed-power devices routinely access field strengths above those at which broad-area, cathode-initiated, high-voltage vacuum-breakdown occur (> 1e7--3e7 V/m). Examples include magnetically-insulated-transmission-lines and current convolutes, high-current-density electron and ion diodes, high-power microwave devices, and cavities and other structures for electrostatic and RF accelerators. Energy deposited in anode surfaces may exceed anode plasma thermal-desorption creation thresholds on the time-scale of the pulse. Stimulated desorption by electron or photon bombardment can also lead to plasma formation on electrode or insulator surfaces. Device performance is limited above these thresholds, particularly in pulse length and energy, by the formation and expansion of plasmas formed primarily from electrode contaminants. In-situ conditioning techniques to modify and eliminate the contaminants through multiple high-voltage pulses, low base pressures, RF discharge cleaning, heating, surface coatings, and ion- and electron-beam surface treatment allow access to new regimes of performance through control of plasma formation and modification of the plasma properties. Experimental and theoretical progress from a variety of devices and small scale experiments with a variety of treatment methods will be reviewed and recommendations given for future work.

  7. Is it a must to add upstream devices for high GVF multiphase

    Energy Technology Data Exchange (ETDEWEB)

    Dou, Jianwen; Guo, Jason; Gokulnath, R.

    2005-07-01

    High accuracies in measurement of the gross liquid and net oil flow rates at high GVF levels in the multiphase flow is identified as one of the most demanding needs of the industry, especially in high water cut environments. The underlying factor that decides the accuracy of the net oil flow rate measurement is the accuracy at which the gross liquid and water cut are measured and the prevailing water cut in the flow. It is an established fact that accuracies falter with increasing GVF in the multiphase flow. The purpose of this paper is to present the performance results of a newly developed Compact High GVF Haimo multiphase meter that addresses the above needs, without having to use an Upstream Separation Device for high GVF application while retaining the accuracies within +2% absolute for water cut and 10% relative for liquid and gas flow rates at 90% confidence level. while also optimising the footprint, the cost, the weight of the solution Further developmental work and trials are in progress to achieve the targeted accuracy levels under very high GVF conditions as well. Contents of the Paper:1) Definitions. 2) MFM 2000 + Upstream Separation Device. 3) Haimo's experience with upstream devices. 4) Motivation to develop the new Compact meter solution. 5) Description of the Compact solution. 6) Performance testing of the Compact solution in a third party test facility. 7) Conclusion and Benefit which are: The objective of working out a new solution for high GVF without having to use a Upstream Separation Device seem to have been achieved with excellent test results; The new configuration of Compact High GVF meter successfully met and exceeded its Acceptance criteria. The main objective was to asses its performance, confirm the quality of the measurements and check its compliance with the Accuracy specifications. The consistency of the absolute error on water cut much lower than 2% for the full range of the GVF and liquid flow rates re-establishes the

  8. Incidence of bisphosphonate-related osteonecrosis of the jaw in high-risk patients undergoing surgical tooth extraction.

    Science.gov (United States)

    Bodem, Jens Philipp; Kargus, Steffen; Eckstein, Stefanie; Saure, Daniel; Engel, Michael; Hoffmann, Jürgen; Freudlsperger, Christian

    2015-05-01

    As the most suitable approach for preventing bisphosphonate-related osteonecrosis of the jaw (BRONJ) in patients undergoing surgical tooth extraction is still under discussion, the present study evaluates the incidence of BRONJ after surgical tooth extraction using a standardized surgical protocol in combination with an adjuvant perioperative treatment setting in patients who are at high-risk for developing BRONJ. High-risk patients were defined as patients who received intravenous bisphosphonate (BP) due to a malignant disease. All teeth were removed using a standardized surgical protocol. The perioperative adjuvant treatment included intravenous antibiotic prophylaxis starting at least 24 h before surgery, a gastric feeding tube and mouth rinses with chlorhexidine (0.12%) three times a day. In the follow-up period patients were examined every 4 weeks for the development of BRONJ. Minimum follow-up was 12 weeks. In 61 patients a total number of 184 teeth were removed from 102 separate extraction sites. In eight patients (13.1%) BRONJ developed during the follow-up. A higher risk for developing BRONJ was found in patients where an additional osteotomy was necessary (21.4% vs. 8.0%; p = 0.0577), especially for an osteotomy of the mandible (33.3% vs. 7.3%; p = 0.0268). Parameters including duration of intravenous antibiotic prophylaxis, the use of a gastric feeding tube and the duration of intravenous BP therapy showed no statistical impact on the development of BRONJ. Furthermore, patients currently undergoing intravenous BP therapy showed no higher risk for BRONJ compared with patients who have paused or completed their intravenous BP therapy (p = 0.4232). This study presents a protocol for surgical tooth extraction in high-risk BP patients in combination with a perioperative adjuvant treatment setting, which reduced the risk for postoperative BRONJ to a minimum. However, the risk for BRONJ increases significantly if an additional osteotomy is necessary

  9. Low Damage, High Anisotropy Inductively Coupled Plasma for Gallium Nitride based Devices

    KAUST Repository

    Ibrahim, Youssef H.

    2013-05-27

    Group III-nitride semiconductors possess unique properties, which make them versatile materials for suiting many applications. Structuring vertical and exceptionally smooth GaN profiles is crucial for efficient optical device operation. The processing requirements for laser devices and ridge waveguides are stringent as compared to LEDs and other electronic devices. Due to the strong bonding and chemically inert nature of GaN, dry etching becomes a critical fabrication step. The surface morphology and facet etch angle are analyzed using SEM and AFM measurements. The influence of different mask materials is also studied including Ni as well as a SiO2 and resist bilayer. The high selectivity Ni Mask is found to produce high sidewall angles ~79°. Processing parameters are optimized for both the mask material and GaN in order to achieve a highly anisotropic, smooth profile, without resorting to additional surface treatment steps. An optimizing a SF6/O2 plasma etch process resulted in smooth SiO2 mask sidewalls. The etch rate and GaN surface roughness dependence on the RF power was also examined. Under a low 2mTorr pressure, the RF and ICP power were optimized to 150W and 300W respectively, such that a smooth GaN morphology and sidewalls was achieved with reduced ion damage. The The AFM measurements of the etched GaN surface indicate a low RMS roughness ranging from 4.75 nm to 7.66 nm.

  10. The Thunderbeat and Other Energy Devices in Laparoscopic Colorectal Resections: Analysis of Outcomes and Costs.

    Science.gov (United States)

    Allaix, Marco Ettore; Arezzo, Alberto; Giraudo, Giuseppe; Arolfo, Simone; Mistrangelo, Massimiliano; Morino, Mario

    2017-12-01

    The THUNDERBEAT™ (TB) is a recently developed energy-based device. To date, there are no clinical studies comparing TB and other energy sources, such as standard electrosurgery (ES), ultrasonic coagulating shears (US) and electrothermal bipolar vessel sealers (EBVS) in patients undergoing laparoscopic colorectal resection (LCR). The aim of this study was to compare outcomes and costs in patients undergoing LCR with TB, US, EBVS, or ES for both benign and malignant colorectal diseases. This study is a retrospective analysis of a prospective database of patients undergoing LCR. Unselected consecutive patients who had the laparoscopic dissection conducted by using TB were compared with consecutive patients undergoing LCR with US, EBVS, or ES. Mean operative time did not significantly differ between the groups (P = .947). Estimated blood loss was significantly higher in the ES group (P < .001). Device-related complications occurred in 2.5% of ES patients, in 2.5% of US patients, and in 5% of EBVS patients, while no complications occurred in TB patients (P = .768). No significant differences were observed in postoperative complication rates between the groups. Mean postoperative hospital stay was similar in the groups. Cost analysis showed no significant differences between US (1519.1 ± 303 €), EBVS (1474.4 ± 372.8 €), and TB (1474.3 ± 176.3 €) (P = .737). This is the first clinical study comparing TB and other energy-based devices in LCR. They all appear to be equally safe and effective. Costs of surgery are very similar. Further large randomized controlled trials are needed to confirm these data.

  11. High performance devices enabled by epitaxial, preferentially oriented, nanodots and/or nanorods

    Science.gov (United States)

    Goyal, Amit [Knoxville, TN

    2011-10-11

    Novel articles and methods to fabricate same with self-assembled nanodots and/or nanorods of a single or multicomponent material within another single or multicomponent material for use in electrical, electronic, magnetic, electromagnetic, superconducting and electrooptical devices is disclosed. Self-assembled nanodots and/or nanorods are ordered arrays wherein ordering occurs due to strain minimization during growth of the materials. A simple method to accomplish this when depositing in-situ films is also disclosed. Device applications of resulting materials are in areas of superconductivity, photovoltaics, ferroelectrics, magnetoresistance, high density storage, solid state lighting, non-volatile memory, photoluminescence, thermoelectrics and in quantum dot lasers.

  12. Design, construction, and characterization of high-performance membrane fusion devices with target-selectivity.

    Science.gov (United States)

    Kashiwada, Ayumi; Yamane, Iori; Tsuboi, Mana; Ando, Shun; Matsuda, Kiyomi

    2012-01-31

    Membrane fusion proteins such as the hemagglutinin glycoprotein have target recognition and fusion accelerative domains, where some synergistically working elements are essential for target-selective and highly effective native membrane fusion systems. In this work, novel membrane fusion devices bearing such domains were designed and constructed. We selected a phenylboronic acid derivative as a recognition domain for a sugar-like target and a transmembrane-peptide (Leu-Ala sequence) domain interacting with the target membrane, forming a stable hydrophobic α-helix and accelerating the fusion process. Artificial membrane fusion behavior between the synthetic devices in which pilot and target liposomes were incorporated was characterized by lipid-mixing and inner-leaflet lipid-mixing assays. Consequently, the devices bearing both the recognition and transmembrane domains brought about a remarkable increase in the initial rate for the membrane fusion compared with the devices containing the recognition domain alone. In addition, a weakly acidic pH-responsive device was also constructed by replacing three Leu residues in the transmembrane-peptide domain by Glu residues. The presence of Glu residues made the acidic pH-dependent hydrophobic α-helix formation possible as expected. The target-selective liposome-liposome fusion was accelerated in a weakly acidic pH range when the Glu-substituted device was incorporated in pilot liposomes. The use of this pH-responsive device seems to be a potential strategy for novel applications in a liposome-based delivery system. © 2011 American Chemical Society

  13. Experiense with remineraling means in patients undergoing orthodontic treatment

    Directory of Open Access Journals (Sweden)

    Stepanova Ye.A.

    2011-03-01

    Full Text Available In patients undergoing orthodontic treatment using bracket-technology a high risk of caries development. The algorithm of preventive interventions for the prevention of hair demineralization of enamel of the teeth

  14. Albumin-Bilirubin and Platelet-Albumin-Bilirubin Grades Accurately Predict Overall Survival in High-Risk Patients Undergoing Conventional Transarterial Chemoembolization for Hepatocellular Carcinoma.

    Science.gov (United States)

    Hansmann, Jan; Evers, Maximilian J; Bui, James T; Lokken, R Peter; Lipnik, Andrew J; Gaba, Ron C; Ray, Charles E

    2017-09-01

    To evaluate albumin-bilirubin (ALBI) and platelet-albumin-bilirubin (PALBI) grades in predicting overall survival in high-risk patients undergoing conventional transarterial chemoembolization for hepatocellular carcinoma (HCC). This single-center retrospective study included 180 high-risk patients (142 men, 59 y ± 9) between April 2007 and January 2015. Patients were considered high-risk based on laboratory abnormalities before the procedure (bilirubin > 2.0 mg/dL, albumin 1.2 mg/dL); presence of ascites, encephalopathy, portal vein thrombus, or transjugular intrahepatic portosystemic shunt; or Model for End-Stage Liver Disease score > 15. Serum albumin, bilirubin, and platelet values were used to determine ALBI and PALBI grades. Overall survival was stratified by ALBI and PALBI grades with substratification by Child-Pugh class (CPC) and Barcelona Liver Clinic Cancer (BCLC) stage using Kaplan-Meier analysis. C-index was used to determine discriminatory ability and survival prediction accuracy. Median survival for 79 ALBI grade 2 patients and 101 ALBI grade 3 patients was 20.3 and 10.7 months, respectively (P  .05). ALBI and PALBI grades are accurate survival metrics in high-risk patients undergoing conventional transarterial chemoembolization for HCC. Use of these scores allows for more refined survival stratification within CPC and BCLC stage. Copyright © 2017 SIR. Published by Elsevier Inc. All rights reserved.

  15. High beta plasma operation in a toroidal plasma producing device

    International Nuclear Information System (INIS)

    Clarke, J.F.

    1978-01-01

    A high beta plasma is produced in a plasma producing device of toroidal configuration by ohmic heating and auxiliary heating. The plasma pressure is continuously monitored and used in a control system to program the current in the poloidal field windings. Throughout the heating process, magnetic flux is conserved inside the plasma and the distortion of the flux surfaces drives a current in the plasma. As a consequence, the total current increases and the poloidal field windings are driven with an equal and opposing increasing current. The spatial distribution of the current in the poloidal field windings is determined by the plasma pressure. Plasma equilibrium is maintained thereby, and high temperature, high beta operation results

  16. High-energy heavy ion testing of VLSI devices for single event ...

    Indian Academy of Sciences (India)

    Unknown

    per describes the high-energy heavy ion radiation testing of VLSI devices for single event upset (SEU) ... The experimental set up employed to produce low flux of heavy ions viz. silicon ... through which they pass, leaving behind a wake of elec- ... for use in Bus Management Unit (BMU) and bulk CMOS ... was scheduled.

  17. High efficiency solid-state sensitized heterojunction photovoltaic device

    KAUST Repository

    Wang, Mingkui

    2010-06-01

    The high molar extinction coefficient heteroleptic ruthenium dye, NaRu(4,4′-bis(5-(hexylthio)thiophen-2-yl)-2,2′-bipyridine) (4-carboxylic acid-4′-carboxylate-2,2′-bipyridine) (NCS) 2, exhibits certified 5% electric power conversion efficiency at AM 1.5 solar irradiation (100 mW cm-2) in a solid-state dye-sensitized solar cell using 2,2′,7,7′-tetrakis-(N,N-di-pmethoxyphenylamine)-9, 9′-spirobifluorene (spiro-MeOTAD) as the organic hole-transporting material. This demonstration elucidates a class of photovoltaic devices with potential for low-cost power generation. © 2010 Elsevier Ltd. All rights reserved.

  18. High efficiency solid-state sensitized heterojunction photovoltaic device

    KAUST Repository

    Wang, Mingkui; Liu, Jingyuan; Cevey-Ha, Ngoc-Le; Moon, Soo-Jin; Liska, Paul; Humphry-Baker, Robin; Moser, Jacques-E.; Grä tzel, Carole; Wang, Peng; Zakeeruddin, Shaik M.

    2010-01-01

    The high molar extinction coefficient heteroleptic ruthenium dye, NaRu(4,4′-bis(5-(hexylthio)thiophen-2-yl)-2,2′-bipyridine) (4-carboxylic acid-4′-carboxylate-2,2′-bipyridine) (NCS) 2, exhibits certified 5% electric power conversion efficiency at AM 1.5 solar irradiation (100 mW cm-2) in a solid-state dye-sensitized solar cell using 2,2′,7,7′-tetrakis-(N,N-di-pmethoxyphenylamine)-9, 9′-spirobifluorene (spiro-MeOTAD) as the organic hole-transporting material. This demonstration elucidates a class of photovoltaic devices with potential for low-cost power generation. © 2010 Elsevier Ltd. All rights reserved.

  19. Noise levels of neonatal high-flow nasal cannula devices--an in-vitro study.

    Science.gov (United States)

    König, Kai; Stock, Ellen L; Jarvis, Melanie

    2013-01-01

    Excessive ambient noise levels have been identified as a potential risk factor for adverse outcome in very preterm infants. Noise level measurements for continuous positive airway pressure (CPAP) devices demonstrated that these constantly exceed current recommendations. The use of high-flow nasal cannula (HFNC) as an alternative non-invasive ventilation modality has become more popular in recent years in neonatal care. To study noise levels of two HFNC devices commonly used in newborns. As a comparison, noise levels of a continuous flow CPAP device were also studied. In-vitro study. The noise levels of two contemporary HFNC devices (Fisher & Paykel NHF™ and Vapotherm Precision Flow®) and one CPAP device (Dräger Babylog® 8000 plus) were measured in the oral cavity of a newborn manikin in an incubator in a quiet environment. HFNC flows of 4-8 l/min and CPAP pressures of 4-8 cm H2O were applied. The CPAP flow was set at 8 l/min as per unit practice. Vapotherm HFNC generated the highest noise levels, measuring 81.2-91.4 dB(A) with increasing flow. Fisher & Paykel HFNC noise levels were between 78.8 and 81.2 dB(A). The CPAP device generated the lowest noise levels between 73.9 and 77.4 dB(A). Both HFNC devices generated higher noise levels than the CPAP device. All noise levels were far above current recommendations of the American Academy of Pediatrics. In light of the long duration of non-invasive respiratory support of very preterm infants, less noisy devices are required to prevent the potentially adverse effects of continuing excessive noise exposure in the neonatal intensive care unit. Copyright © 2013 S. Karger AG, Basel.

  20. Laser, light, and energy devices for cellulite and lipodystrophy.

    Science.gov (United States)

    Peterson, Jennifer D; Goldman, Mitchel P

    2011-07-01

    Cellulite affects all races, and it is estimated that 85% of women older than 20 years have some degree of cellulite. Many currently accepted cellulite therapies target deficiencies in lymphatic drainage and microvascular circulation. Devices using radiofrequency, laser, and light-based energies, alone or in combination and coupled frequently with tissue manipulation, are available for improving cellulite. Laser assisted liposuction may improve cellulite appearance. Although improvement using these devices is temporary, it may last several months. Patients who want smoother skin with less visible cellulite can undergo a series of treatments and then return for additional treatments as necessary. Copyright © 2011 Elsevier Inc. All rights reserved.

  1. Technology breakthroughs in high performance metal-oxide-semiconductor devices for ultra-high density, low power non-volatile memory applications

    Science.gov (United States)

    Hong, Augustin Jinwoo

    Non-volatile memory devices have attracted much attention because data can be retained without power consumption more than a decade. Therefore, non-volatile memory devices are essential to mobile electronic applications. Among state of the art non-volatile memory devices, NAND flash memory has earned the highest attention because of its ultra-high scalability and therefore its ultra-high storage capacity. However, human desire as well as market competition requires not only larger storage capacity but also lower power consumption for longer battery life time. One way to meet this human desire and extend the benefits of NAND flash memory is finding out new materials for storage layer inside the flash memory, which is called floating gate in the state of the art flash memory device. In this dissertation, we study new materials for the floating gate that can lower down the power consumption and increase the storage capacity at the same time. To this end, we employ various materials such as metal nanodot, metal thin film and graphene incorporating complementary-metal-oxide-semiconductor (CMOS) compatible processes. Experimental results show excellent memory effects at relatively low operating voltages. Detailed physics and analysis on experimental results are discussed. These new materials for data storage can be promising candidates for future non-volatile memory application beyond the state of the art flash technologies.

  2. Mortality Among Patients with Pleural Effusion Undergoing Thoracentesis

    Science.gov (United States)

    DeBiasi, Erin M.; Pisani, Margaret A.; Murphy, Terrence E.; Araujo, Katy; Kookoolis, Anna; Argento, A Christine; Puchalski, Jonathan

    2016-01-01

    Background Of the 1.5 million people diagnosed with pleural effusion annually in the U.S., approximately 178,000 undergo thoracentesis. While it is known that malignant pleural effusion portends a poor prognosis, mortality of patients with nonmalignant effusions has not been well studied. Methods This prospective cohort study evaluated 308 patients undergoing thoracentesis. Chart review was performed to obtain baseline characteristics. The etiology of the effusions was determined using standardized criteria. Mortality was determined at 30-days and 1-year. Results 247 unilateral and 61 bilateral thoracenteses were performed. Malignant effusion had the highest 30-day (37%) and 1 year (77%) mortality. There was substantial patient 30-day and 1-year mortality with effusions due to multiple benign etiologies (29% and 55%), CHF (22% and 53%), and renal failure (14% and 57%). Patients with bilateral pleural effusion, relative to unilateral, were associated with higher risk of death at 30 days and 1 year (17% versus 47%; HR 2.58 CI [1.44–4.63] and 36% versus 69%; HR 2.32 CI [1.55–3.48]). Conclusions Patients undergoing thoracentesis for pleural effusion have high short and long-term mortality. Patients with malignant effusion had the highest mortality followed by multiple benign etiologies, CHF and renal failure. Bilateral pleural effusion is distinctly associated with high mortality. PMID:25837039

  3. Use of a pocket compression device for the prevention and treatment of pocket hematoma after pacemaker and defibrillator implantation (STOP-HEMATOMA-I).

    Science.gov (United States)

    Turagam, Mohit K; Nagarajan, Darbhamulla V; Bartus, Krzysztof; Makkar, Akash; Swarup, Vijay

    2017-08-01

    Pocket hematoma is a recognized complication after placement of cardiac implantable electronic devices and is associated with increased device infection, length of hospitalization, and morbidity especially with uninterrupted antiplatelet agents and anticoagulants. We assessed the use of a post-surgical vest to decrease the incidence of pocket hematoma in patients undergoing device implantation with uninterrupted antiplatelet and anticoagulants. In this observational study, a vest was used by 20 consecutive patients who were compared to 20 age-, gender-, procedure-matched patients who received standard care. All patients were continued on antiplatelet and anticoagulants in the perioperative period. The pocket was assessed at post procedure day 0, 2, and 7, respectively. There were no significant differences in the baseline characteristics between both groups. Baseline mean international normalized ratio (INR) was significantly higher in the vest group when compared with the control group (2.7 ± 0.4 vs. 2.2 ± 0.3 = hematoma was significantly lower in the vest group than the control group (0 vs 30%, p = 0.02) at the end of 7 days. Control group had a total of six hematomas with one patient requiring evacuation and blood transfusion. The vest group had three hematomas on day 2 that resolved by day 7. The risk of moderate or large pocket hematoma is significantly reduced with the use of this vest in high-risk patients undergoing implantable devices on uninterrupted antiplatelet and anticoagulants.

  4. Electromechanical stability of electro-active silicone filled with high permittivity particles undergoing large deformation

    International Nuclear Information System (INIS)

    Liu, Liwu; Liu, Yanju; Zhang, Zhen; Leng, Jinsong; Li, Bo

    2010-01-01

    In this paper, an expression for the permittivity of electro-active silicone undergoing large deformation with high permittivity particles filled uniformly has been proposed. Two expressions are proposed for the permittivity, one based on experimental tests and the other based on the theory of composite material. By applying the thermodynamic model incorporating linear dielectric permittivity and nonlinear hyperelastic performance, the mechanical performance and electromechanical stability of the coupling system constituted by silicone filled with PMN–PT have been studied. The results show that the critical electric field decreases, namely the stability performance of the system declines when the content of PMN–PT c(v) increases and the electrostrictive coefficients increase. The results are beneficial for us to understand deeply the influence of the filled particle on the stability performance of silicone and to guide the design and manufacture of actuators and sensors based on dielectric elastomers

  5. Many-junction photovoltaic device performance under non-uniform high-concentration illumination

    Science.gov (United States)

    Valdivia, Christopher E.; Wilkins, Matthew M.; Chahal, Sanmeet S.; Proulx, Francine; Provost, Philippe-Olivier; Masson, Denis P.; Fafard, Simon; Hinzer, Karin

    2017-09-01

    A parameterized 3D distributed circuit model was developed to calculate the performance of III-V solar cells and photonic power converters (PPC) with a variable number of epitaxial vertically-stacked pn junctions. PPC devices are designed with many pn junctions to realize higher voltages and to operate under non-uniform illumination profiles from a laser or LED. Performance impacts of non-uniform illumination were greatly reduced with increasing number of junctions, with simulations comparing PPC devices with 3 to 20 junctions. Experimental results using Azastra Opto's 12- and 20-junction PPC illuminated by an 845 nm diode laser show high performance even with a small gap between the PPC and optical fiber output, until the local tunnel junction limit is reached.

  6. A design of an on-orbit radiometric calibration device for high dynamic range infrared remote sensors

    Science.gov (United States)

    Sheng, Yicheng; Jin, Weiqi; Dun, Xiong; Zhou, Feng; Xiao, Si

    2017-10-01

    With the demand of quantitative remote sensing technology growing, high reliability as well as high accuracy radiometric calibration technology, especially the on-orbit radiometric calibration device has become an essential orientation in term of quantitative remote sensing technology. In recent years, global launches of remote sensing satellites are equipped with innovative on-orbit radiometric calibration devices. In order to meet the requirements of covering a very wide dynamic range and no-shielding radiometric calibration system, we designed a projection-type radiometric calibration device for high dynamic range sensors based on the Schmidt telescope system. In this internal radiometric calibration device, we select the EF-8530 light source as the calibration blackbody. EF-8530 is a high emittance Nichrome (Ni-Cr) reference source. It can operate in steady or pulsed state mode at a peak temperature of 973K. The irradiance from the source was projected to the IRFPA. The irradiance needs to ensure that the IRFPA can obtain different amplitude of the uniform irradiance through the narrow IR passbands and cover the very wide dynamic range. Combining the internal on-orbit radiometric calibration device with the specially designed adaptive radiometric calibration algorithms, an on-orbit dynamic non-uniformity correction can be accomplished without blocking the optical beam from outside the telescope. The design optimizes optics, source design, and power supply electronics for irradiance accuracy and uniformity. The internal on-orbit radiometric calibration device not only satisfies a series of indexes such as stability, accuracy, large dynamic range and uniformity of irradiance, but also has the advantages of short heating and cooling time, small volume, lightweight, low power consumption and many other features. It can realize the fast and efficient relative radiometric calibration without shielding the field of view. The device can applied to the design and

  7. Very High Output Thermoelectric Devices Based on ITO Nanocomposites

    Science.gov (United States)

    Fralick, Gustave; Gregory, Otto J.

    2009-01-01

    A material having useful thermoelectric properties was synthesized by combining indium-tin-oxide (ITO) with a NiCoCrAlY alloy/alumina cermet. This material had a very large Seebeck coefficient with electromotive-force-versustemperature behavior that is considered to be excellent with respect to utility in thermocouples and other thermoelectric devices. When deposited in thin-film form, ceramic thermocouples offer advantages over precious-metal (based, variously, on platinum or rhodium) thermocouples that are typically used in gas turbines. Ceramic thermocouples exhibit high melting temperatures, chemical stability at high temperatures, and little or no electromigration. Oxide ceramics also resist oxidation better than metal thermocouples, cost substantially less than precious-metal thermocouples, and, unlike precious-metal thermocouples, do not exert catalytic effects.

  8. Improvements of ModalMax High-Fidelity Piezoelectric Audio Device

    Science.gov (United States)

    Woodard, Stanley E.

    2005-01-01

    ModalMax audio speakers have been enhanced by innovative means of tailoring the vibration response of thin piezoelectric plates to produce a high-fidelity audio response. The ModalMax audio speakers are 1 mm in thickness. The device completely supplants the need to have a separate driver and speaker cone. ModalMax speakers can perform the same applications of cone speakers, but unlike cone speakers, ModalMax speakers can function in harsh environments such as high humidity or extreme wetness. New design features allow the speakers to be completely submersed in salt water, making them well suited for maritime applications. The sound produced from the ModalMax audio speakers has sound spatial resolution that is readily discernable for headset users.

  9. Modeling of transient ionizing radiation effects in bipolar devices at high dose-rates

    International Nuclear Information System (INIS)

    FJELDLY, T.A.; DENG, Y.; SHUR, M.S.; HJALMARSON, HAROLD P.; MUYSHONDT, ARNOLDO

    2000-01-01

    To optimally design circuits for operation at high intensities of ionizing radiation, and to accurately predict their a behavior under radiation, precise device models are needed that include both stationary and dynamic effects of such radiation. Depending on the type and intensity of the ionizing radiation, different degradation mechanisms, such as photoelectric effect, total dose effect, or single even upset might be dominant. In this paper, the authors consider the photoelectric effect associated with the generation of electron-hole pairs in the semiconductor. The effects of low radiation intensity on p-II diodes and bipolar junction transistors (BJTs) were described by low-injection theory in the classical paper by Wirth and Rogers. However, in BJTs compatible with modem integrated circuit technology, high-resistivity regions are often used to enhance device performance, either as a substrate or as an epitaxial layer such as the low-doped n-type collector region of the device. Using low-injection theory, the transient response of epitaxial BJTs was discussed by Florian et al., who mainly concentrated on the effects of the Hi-Lo (high doping - low doping) epilayer/substrate junction of the collector, and on geometrical effects of realistic devices. For devices with highly resistive regions, the assumption of low-level injection is often inappropriate, even at moderate radiation intensities, and a more complete theory for high-injection levels was needed. In the dynamic photocurrent model by Enlow and Alexander. p-n junctions exposed to high-intensity radiation were considered. In their work, the variation of the minority carrier lifetime with excess carrier density, and the effects of the ohmic electric field in the quasi-neutral (q-n) regions were included in a simplified manner. Later, Wunsch and Axness presented a more comprehensive model for the transient radiation response of p-n and p-i-n diode geometries. A stationary model for high-level injection in p

  10. Optimal location of shunt FACTS devices in a power system with high wind feeding

    Energy Technology Data Exchange (ETDEWEB)

    Shakib, Arefeh Danesh; Balzer, Gerd [Technische Univ. Darmstadt (Germany). Inst. of Electrical Power Systems

    2009-07-01

    Connections of large offshore wind farms, which will be placed in the North Sea, will lead to several problems in Germany's power system. One of these is the occurance of undervoltage at weak nodes due to the reduction of reactive power generation. This paper is covering several singular analyses of the system Jacobin matrix whose results are applied to identify sensors and weak places in power systems with high wind feeding. This allows for the solution of optimal location of shunt FACTS devices for example static var compensators (SVC) for voltage control. The optimizations are made on two parameters: the location of the devices and their sizes. Simulations are performed on a IEEE 57-bus system for several wind feeding scenarios. It can be shown that by use of optimal placed FACTS devices the voltage stability of the power system in the case of high wind feeding can be guaranteed. (orig.)

  11. An opioid-based pain control program for head and neck cancer patients undergoing chemoradiation therapy achieves a high completion rate of radiation

    International Nuclear Information System (INIS)

    Kato, Kengo; Matsuura, Kazuto; Zenda, Sadamoto

    2011-01-01

    Appropriate supportive care is essential for intensive chemoradiation therapy (CRT), and pain management is an important supportive care for CRT for head and neck cancer. We developed an opioid-based pain control program for head and neck cancer patients undergoing CRT, and assessed its efficacy and safety. 110 head and neck cancer patients undergoing platinum-based concomitant CRT were enrolled from 10 cancer centers or university hospitals. Their pain caused by CRT was managed with a four-step opioid-based pain control program, and adverse events and usage of opioid were analyzed. 101 suitable cases of 110 patients were analyzed. 53% of cases suffered grade 3-4 mucositis. The rate of completion of radiotherapy was 99% and the rate of unplanned breaks in radiotherapy was 13%. The usage rate of opioid was 83% and the rate of compliance with the pain control program was 92%. The median maximum quantity of morphine used per day was 35 mg. No patient had to stop the opioid program or radiotherapy due to adverse effects of opioids. An opioid-based pain control program for head and neck cancer patients undergoing CRT achieves a high completion rate of radiation. (author)

  12. Hypovitaminosis D in patients undergoing kidney transplant: the importance of sunlight exposure

    Directory of Open Access Journals (Sweden)

    Cristiane F. Vilarta

    Full Text Available OBJECTIVES: Recent studies have shown a high prevalence of hypovitaminosis D, defined as a serum 25-hydroxyvitamin D level less than 30 ng/ml, in both healthy populations and patients with chronic kidney disease. Patients undergoing kidney transplant are at an increased risk of skin cancer and are advised to avoid sunlight exposure. Therefore, these patients might share two major risk factors for hypovitaminosis D: chronic kidney disease and low sunlight exposure. This paper describes the prevalence and clinical characteristics of hypovitaminosis D among patients undergoing kidney transplant. METHODS: We evaluated 25-hydroxyvitamin D serum levels in a representative sample of patients undergoing kidney transplant. We sought to determine the prevalence of hypovitaminosis D, compare these patients with a control group, and identify factors associated with hypovitaminosis D (e.g., sunlight exposure and dietary habits. RESULTS: Hypovitaminosis D was found in 79% of patients undergoing kidney transplant, and the major associated factor was low sunlight exposure. These patients had higher creatinine and intact parathyroid hormone serum levels, with 25-hydroxyvitamin D being inversely correlated with intact parathyroid hormone serum levels. Compared with the control group, patients undergoing kidney transplant presented a higher prevalence of 25-hydroxyvitamin D deficiency and lower serum calcium, phosphate and albumin but higher creatinine and intact parathyroid hormone levels. CONCLUSIONS: Our results confirmed the high prevalence of hypovitaminosis D in patients undergoing kidney transplant. Therapeutic strategies such as moderate sunlight exposure and vitamin D supplementation should be seriously considered for this population.

  13. Radiation effects on semiconductor devices in high energy heavy ion accelerators

    Energy Technology Data Exchange (ETDEWEB)

    Belousov, Anton

    2014-10-20

    Radiation effects on semiconductor devices in GSI Helmholtz Center for Heavy Ion Research are becoming more and more significant with the increase of beam intensity due to upgrades. Moreover a new accelerator is being constructed on the basis of GSI within the project of facility for antiproton and ion research (FAIR). Beam intensities will be increased by factor of 100 and energies by factor of 10. Radiation fields in the vicinity of beam lines will increase more than 2 orders of magnitude and so will the effects on semiconductor devices. It is necessary to carry out a study of radiation effects on semiconductor devices considering specific properties of radiation typical for high energy heavy ion accelerators. Radiation effects on electronics in accelerator environment may be divided into two categories: short-term temporary effects and long-term permanent degradation. Both may become critical for proper operation of some electronic devices. This study is focused on radiation damage to CCD cameras in radiation environment of heavy ion accelerator. Series of experiments with irradiation of devices under test (DUTs) by secondary particles produced during ion beam losses were done for this study. Monte Carlo calculations were performed to simulate the experiment conditions and conditions expected in future accelerator. Corresponding comparisons and conclusions were done. Another device typical for accelerator facilities - industrial Ethernet switch was tested in similar conditions during this study. Series of direct irradiations of CCD and MOS transistors with heavy ion beams were done as well. Typical energies of the primary ion beams were 0.5-1 GeV/u. Ion species: from Na to U. Intensities of the beam up to 10{sup 9} ions/spill with spill length of 200-300 ns. Criteria of reliability and lifetime of DUTs in specific radiation conditions were formulated, basing on experimental results of the study. Predictions of electronic device reliability and lifetime were

  14. Laser-induced local activation of Mg-doped GaN with a high lateral resolution for high power vertical devices

    Science.gov (United States)

    Kurose, Noriko; Matsumoto, Kota; Yamada, Fumihiko; Roffi, Teuku Muhammad; Kamiya, Itaru; Iwata, Naotaka; Aoyagi, Yoshinobu

    2018-01-01

    A method for laser-induced local p-type activation of an as-grown Mg-doped GaN sample with a high lateral resolution is developed for realizing high power vertical devices for the first time. As-grown Mg-doped GaN is converted to p-type GaN in a confined local area. The transition from an insulating to a p-type area is realized to take place within about 1-2 μm fine resolution. The results show that the technique can be applied in fabricating the devices such as vertical field effect transistors, vertical bipolar transistors and vertical Schottkey diode so on with a current confinement region using a p-type carrier-blocking layer formed by this technique.

  15. High performance solution processed zirconium oxide gate dielectric appropriate for low temperature device application

    Energy Technology Data Exchange (ETDEWEB)

    Hasan, Musarrat; Nguyen, Manh-Cuong; Kim, Hyojin; You, Seung-Won; Jeon, Yoon-Seok; Tong, Duc-Tai; Lee, Dong-Hwi; Jeong, Jae Kyeong; Choi, Rino, E-mail: rino.choi@inha.ac.kr

    2015-08-31

    This paper reports a solution processed electrical device with zirconium oxide gate dielectric that was fabricated at a low enough temperature appropriate for flexible electronics. Both inorganic dielectric and channel materials were synthesized in the same organic solvent. The dielectric constant achieved was 13 at 250 °C with a reasonably low leakage current. The bottom gate transistor devices showed the highest mobility of 75 cm{sup 2}/V s. The device is operated at low voltage with high-k dielectric with excellent transconductance and low threshold voltage. Overall, the results highlight the potential of low temperature solution based deposition in fabricating more complicated circuits for a range of applications. - Highlights: • We develop a low temperature inorganic dielectric deposition process. • We fabricate oxide semiconductor channel devices using all-solution processes. • Same solvent is used for dielectric and oxide semiconductor deposition.

  16. An investigation of highly accurate and precise robotic hole measurements using non-contact devices

    Directory of Open Access Journals (Sweden)

    Usman Zahid

    2016-01-01

    Full Text Available Industrial robots arms are widely used in manufacturing industry because of their support for automation. However, in metrology, robots have had limited application due to their insufficient accuracy. Even using error compensation and calibration methods, robots are not effective for micrometre (μm level metrology. Non-contact measurement devices can potentially enable the use of robots for highly accurate metrology. However, the use of such devices on robots has not been investigated. The research work reported in this paper explores the use of different non-contact measurement devices on an industrial robot. The aim is to experimentally investigate the effects of robot movements on the accuracy and precision of measurements. The focus has been on assessing the ability to accurately measure various geometric and surface parameters of holes despite the inherent inaccuracies of industrial robot. This involves the measurement of diameter, roundness and surface roughness. The study also includes scanning of holes for measuring internal features such as start and end point of a taper. Two different non-contact measurement devices based on different technologies are investigated. Furthermore, effects of eccentricity, vibrations and thermal variations are also assessed. The research contributes towards the use of robots for highly accurate and precise robotic metrology.

  17. Optimisation of a novel trailing edge concept for a high lift device

    CSIR Research Space (South Africa)

    Botha, JDM

    2014-09-01

    Full Text Available A novel concept (referred to as the flap extension) is implemented on the leading edge of the flap of a three element high lift device. The concept is optimised using two optimisation approaches based on Genetic Algorithm optimisations. A zero order...

  18. Thermal neutron moderating device

    International Nuclear Information System (INIS)

    Takigami, Hiroyuki.

    1995-01-01

    In a thermal neutron moderating device, superconductive coils for generating magnetic fields capable of applying magnetic fields vertical to the longitudinal direction of a thermal neutron passing tube, and superconductive coils for magnetic field gradient for causing magnetic field gradient in the longitudinal direction of the thermal neutron passing tube are disposed being stacked at the outside of the thermal neutron passing tube. When magnetic field gradient is present vertically to the direction of a magnetic moment, thermal neutrons undergo forces in the direction of the magnetic field gradient in proportion to the magnetic moment. Then, the magnetic moment of the thermal neutrons is aligned with the direction vertical to the passing direction of the thermal neutrons, to cause the magnetic field gradient in the passing direction of the thermal neutrons. The speed of the thermal neutrons can be optionally selected and the wavelength can freely be changed by applying forces to the thermal neutrons and changing the extent and direction of the magnetic field gradient. Superconductive coils are used as the coils for generating magnetic fields and the magnetic field gradient in order to change extremely high energy of the thermal neutrons. (N.H.)

  19. Achieving Ohmic Contact for High-quality MoS2 Devices on Hexagonal Boron Nitride

    Science.gov (United States)

    Cui, Xu

    MoS2, among many other transition metal dichalcogenides (TMDCs), holds great promise for future applications in nano-electronics, opto-electronics and mechanical devices due to its ultra-thin nature, flexibility, sizable band-gap, and unique spin-valley coupled physics. However, there are two main challenges that hinder careful study of this material. Firstly, it is hard to achieve Ohmic contacts to mono-layer MoS2, particularly at low temperatures (T) and low carrier densities. Secondly, materials' low quality and impurities introduced during the fabrication significantly limit the electron mobility of mono- and few-layer MoS2 to be substantially below theoretically predicted limits, which has hampered efforts to observe its novel quantum transport behaviours. Traditional low work function metals doesn't necessary provide good electron injection to thin MoS2 due to metal oxidation, Fermi level pinning, etc. To address the first challenge, we tried multiple contact schemes and found that mono-layer hexagonal boron nitride (h-BN) and cobalt (Co) provide robust Ohmic contact. The mono-layer spacer serves two advantageous purposes: it strongly interacts with the transition metal, reducing its work function by over 1 eV; and breaks the metal-TMDCs interaction to eliminate the interfacial states that cause Fermi level pinning. We measure a flat-band Schottky barrier of 16 meV, which makes thin tunnel barriers upon doping the channels, and thus achieve low-T contact resistance of 3 kohm.um at a carrier density of 5.3x10. 12/cm. 2. Similar to graphene, eliminating all potential sources of disorder and scattering is the key to achieving high performance in MoS2 devices. We developed a van der Waals heterostructure device platform where MoS2 layers are fully encapsulated within h-BN and electrically contacted in a multi-terminal geometry using gate-tunable graphene electrodes. The h-BN-encapsulation provides excellent protection from environmental factors, resulting in

  20. Device for plasma confinement and heating by high currents and nonclassical plasma transport properties

    Science.gov (United States)

    Coppi, B.; Montgomery, D.B.

    1973-12-11

    A toroidal plasma containment device having means for inducing high total plasma currents and current densities and at the same time emhanced plasma heating, strong magnetic confinement, high energy density containment, magnetic modulation, microwaveinduced heating, and diagnostic accessibility is described. (Official Gazette)

  1. Highly efficient and heavily-doped organic light-emitting devices based on an orange phosphorescent iridium complex

    International Nuclear Information System (INIS)

    Zhou, Shunliang; Wang, Qi; Li, Ming; Lu, Zhiyun; Yu, Junsheng

    2014-01-01

    Heavily doped and highly efficient phosphorescent organic light-emitting devices (PhOLEDs) had been fabricated by utilizing an orange iridium complex, bis[2-(3′,5′-di-tert-butylbiphenyl-4-yl)benzothiazolato-N,C 2' ]iridium(III) (acetylacetonate) [(tbpbt) 2 Ir(acac)], as a phosphor. When the doping concentration of [(tbpbt) 2 Ir(acac)] reached as high as 15 wt%, the PhOLEDs exhibited a power efficiency, current efficiency, and external quantum efficiency of 24.5 lm/W, 32.1 cd/A, 15.7%, respectively, implying a promising quenching-resistant characteristics of this novel phosphor. Furthermore, the efficient white PhOLEDs had been obtained by employing (tbpbt) 2 Ir(acac) as a self-host orange emitter, indicating that (tbpbt) 2 Ir(acac) could serve as a promising phosphor to fabricate white organic light-emitting devices with simplified manufacturing process. - Highlights: • Efficient phosphorescent devices were fabricated. • Optimized phosphor doping ratio reached as high as 15 wt%. • The results proved a promising quench-resistant property of the phosphor. • Efficient white devices based on this phosphor as self-host layer had been realized

  2. Highly efficient and heavily-doped organic light-emitting devices based on an orange phosphorescent iridium complex

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, Shunliang; Wang, Qi [State Key Laboratory of Electronic Thin Films and Integrated Devices, School of Optoelectronic Information, University of Electronic Science and Technology of China (UESTC), Chengdu 610054 (China); Li, Ming [College of Chemistry, Sichuan University, Chengdu, 610064 (China); Lu, Zhiyun, E-mail: luzhiyun@scu.edu.cn [College of Chemistry, Sichuan University, Chengdu, 610064 (China); Yu, Junsheng, E-mail: jsyu@uestc.edu.cn [State Key Laboratory of Electronic Thin Films and Integrated Devices, School of Optoelectronic Information, University of Electronic Science and Technology of China (UESTC), Chengdu 610054 (China)

    2014-10-15

    Heavily doped and highly efficient phosphorescent organic light-emitting devices (PhOLEDs) had been fabricated by utilizing an orange iridium complex, bis[2-(3′,5′-di-tert-butylbiphenyl-4-yl)benzothiazolato-N,C{sup 2'}]iridium(III) (acetylacetonate) [(tbpbt){sub 2}Ir(acac)], as a phosphor. When the doping concentration of [(tbpbt){sub 2}Ir(acac)] reached as high as 15 wt%, the PhOLEDs exhibited a power efficiency, current efficiency, and external quantum efficiency of 24.5 lm/W, 32.1 cd/A, 15.7%, respectively, implying a promising quenching-resistant characteristics of this novel phosphor. Furthermore, the efficient white PhOLEDs had been obtained by employing (tbpbt){sub 2}Ir(acac) as a self-host orange emitter, indicating that (tbpbt){sub 2}Ir(acac) could serve as a promising phosphor to fabricate white organic light-emitting devices with simplified manufacturing process. - Highlights: • Efficient phosphorescent devices were fabricated. • Optimized phosphor doping ratio reached as high as 15 wt%. • The results proved a promising quench-resistant property of the phosphor. • Efficient white devices based on this phosphor as self-host layer had been realized.

  3. High mobility AlGaN/GaN devices for β{sup −}-dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Schmid, Martin; Howgate, John; Ruehm, Werner [Helmholtz Zentrum München, Ingolstädter Landstraße 1, 85764 Neuherberg (Germany); Thalhammer, Stefan, E-mail: stefan.thalhammer@physik.uni-augsburg.de [Universität Augsburg, Universitätsstraße 1, 86159 Augsburg (Germany)

    2016-05-21

    There is a high demand in modern medical applications for dosimetry sensors with a small footprint allowing for unobtrusive or high spatial resolution detectors. To this end we characterize the sensoric response of radiation resistant high mobility AlGaN/GaN semiconductor devices when exposed to β{sup −}-emitters. The samples were operated as a floating gate transistor, without a field effect gate electrode, thus excluding any spurious effects from β{sup −}-particle interactions with a metallic surface covering. We demonstrate that the source–drain current is modulated in dependence on the kinetic energy of the incident β{sup −}-particles. Here, the signal is shown to have a linear dependence on the absorbed energy calculated from Monte Carlo simulations. Additionally, a stable and reproducible sensor performance as a β{sup −}-dose monitor is shown for individual radioisotopes. Our experimental findings and the characteristics of the AlGaN/GaN high mobility layered devices indicate their potential for future applications where small sensor size is necessary, like for instance brachytherapy.

  4. Release strategies for making transferable semiconductor structures, devices and device components

    Science.gov (United States)

    Rogers, John A; Nuzzo, Ralph G; Meitl, Matthew; Ko, Heung Cho; Yoon, Jongseung; Menard, Etienne; Baca, Alfred J

    2014-11-25

    Provided are methods for making a device or device component by providing a multilayer structure having a plurality of functional layers and a plurality of release layers and releasing the functional layers from the multilayer structure by separating one or more of the release layers to generate a plurality of transferable structures. The transferable structures are printed onto a device substrate or device component supported by a device substrate. The methods and systems provide means for making high-quality and low-cost photovoltaic devices, transferable semiconductor structures, (opto-)electronic devices and device components.

  5. Electronic Devices for Controlling the Very High Voltage in the ALICE TPC Detector

    CERN Document Server

    Boccioli, Marco

    2007-01-01

    The Time Projection Chamber (TPC) is the core of the ALICE experiment at CERN. The TPC Very High Voltage project covers the development of the control system for the power supply that generates the 100kV necessary for the drift field in the TPC. This paper reports on the project progress, introducing the control system architecture from the electronics up to the control level. All the electronic devices will be described, highlighting their communication issues, and the challenges in integrating these devices in a PLC-based control system.

  6. Low-voltage and high-efficiency white organic light emitting devices with carrier balance

    International Nuclear Information System (INIS)

    Wei Fuxiang; Huang, Y.; Fang, L.

    2010-01-01

    White organic light emitting devices with the structure of ITO/m-MTDATA:x%4F-TCNQ/NPB/TBADN:EBDP:DCJTB/Bphen:Liq/LiF/Al have been demonstrated in this paper. High-mobility m-MTDATA:4F-TCNQ is added into the region between ITO and NBP to increase hole injection and transport. The high-mobility Bphen:Liq layer is added into the region between cathode and emission layers to lower cathode barrier and facilitate carrier injection. In the meanwhile, an effective carrier balance (number of holes is equal to number of electrons) between holes and electrons is considered to be one of the most important factors for improving OLEDs. During the experiment, by modulating the doping concentration of 4F-TCNQ, we can control hole injection and transport to make the carriers reach a high-level balance. The maximum current efficiency and power efficiency of devices were 9.3 cd/A and 4.6 lm/A, respectively.

  7. Direct Photolithography on Molecular Crystals for High Performance Organic Optoelectronic Devices.

    Science.gov (United States)

    Yao, Yifan; Zhang, Lei; Leydecker, Tim; Samorì, Paolo

    2018-05-23

    Organic crystals are generated via the bottom-up self-assembly of molecular building blocks which are held together through weak noncovalent interactions. Although they revealed extraordinary charge transport characteristics, their labile nature represents a major drawback toward their integration in optoelectronic devices when the use of sophisticated patterning techniques is required. Here we have devised a radically new method to enable the use of photolithography directly on molecular crystals, with a spatial resolution below 300 nm, thereby allowing the precise wiring up of multiple crystals on demand. Two archetypal organic crystals, i.e., p-type 2,7-diphenyl[1]benzothieno[3,2- b][1]benzothiophene (Dph-BTBT) nanoflakes and n-type N, N'-dioctyl-3,4,9,10-perylenedicarboximide (PTCDI-C8) nanowires, have been exploited as active materials to realize high-performance top-contact organic field-effect transistors (OFETs), inverter and p-n heterojunction photovoltaic devices supported on plastic substrate. The compatibility of our direct photolithography technique with organic molecular crystals is key for exploiting the full potential of organic electronics for sophisticated large-area devices and logic circuitries, thus paving the way toward novel applications in plastic (opto)electronics.

  8. Patterning solution-processed organic single-crystal transistors with high device performance

    Directory of Open Access Journals (Sweden)

    Yun Li

    2011-06-01

    Full Text Available We report on the patterning of organic single-crystal transistors with high device performance fabricated via a solution process under ambient conditions. The semiconductor was patterned on substrates via surface selective deposition. Subsequently, solvent-vapor annealing was performed to reorganize the semiconductor into single crystals. The transistors exhibited field-effect mobility (μFET of up to 3.5 cm2/V s. Good reliability under bias-stress conditions indicates low density of intrinsic defects in crystals and low density of traps at the active interfaces. Furthermore, the Y function method clearly suggests that the variation of μFET of organic crystal transistors was caused by contact resistance. Further improvement of the device with higher μFET with smaller variation can be expected when lower and more uniform contact resistance is achieved.

  9. Fundamental investigation of high temperature operation of field effect transistor devices

    Science.gov (United States)

    Chern, Jehn-Huar

    In this dissertation copper germanium (CuGe)-based materials were investigated as potential ohmic contacts to n-type gallium arsenide (GaAs). The CuGe-based contacts to GaAs were found to not form any reaction products with GaAs and to have low contact resistance comparable to that of nickel gold germanium (NiAuGe) ohmic contacts to GaAs. The potential for high temperature applications using CuGe ohmic contacts was investigated. A guideline for further reduction of the contact resistance has been achieved after investigating the detailed mechanism of the formation of binary CuGe contacts over a wide range of Ge concentrations. The thermal stability of CuGe contacts was significantly enhanced and improved by introducing a diffusion barrier, titanium tungsten nitride (TiWNx), and a gold (Au) overlayer for high temperature applications. Novel approaches such as epitaxial thulium phosphide (TmP) Schottky contacts and the utilization of low temperature (LT)-aluminum gallium arsenide (AlGaAs) were also investigated in this dissertation and likely will be the standard technologies for a new generation of high-temperature electronics. Inserting a layer of aluminum arsenide (AlAs) underneath the channel of a GaAs-based MESFET was found to reduce substrate leakage currents by a factor of 30 compared with the same MESFET directly fabricated on a semi-insulating GaAs substrate. In addition to AlAs, and AlxGa1-xAs materials, new materials grown at low temperatures such as LT-AlGaAs were used in heterojunction FET structures as a back wall barrier. Low drain leakage currents were achieved using AlAs and LT-AlGaAs as the back wall barriers. Some fundamental properties regarding these materials are of great interest and in need of further characterization. Part of the work in this dissertation was devoted to the characterization of device performance for different structure designs at elevated temperatures. The suitability of GaAs-based and gallium arsenide (GaN)-based MESFET

  10. High-efficiency white organic light-emitting devices with a non-doped yellow phosphorescent emissive layer

    Energy Technology Data Exchange (ETDEWEB)

    Zhao Juan; Yu Junsheng, E-mail: jsyu@uestc.edu.cn; Hu Xiao; Hou Menghan; Jiang Yadong

    2012-03-30

    Highly efficient phosphorescent white organic light-emitting devices (PHWOLEDs) with a simple structure of ITO/TAPC (40 nm)/mCP:FIrpic (20 nm, x wt.%)/bis[2-(4-tertbutylphenyl)benzothiazolato-N,C{sup 2} Prime ] iridium (acetylacetonate) (tbt){sub 2}Ir(acac) (y nm)/Bphen (30 nm)/Mg:Ag (200 nm) have been developed, by inserting a thin layer of non-doped yellow phosphorescent (tbt){sub 2}Ir(acac) between doped blue emitting layer (EML) and electron transporting layer. By changing the doping concentration of the blue EML and the thickness of the non-doped yellow EML, a PHWOLED comprised of higher blue doping concentration and thinner yellow EML achieves a high current efficiency of 31.7 cd/A and Commission Internationale de l'Eclairage coordinates of (0.33, 0.41) at a luminance of 3000 cd/m{sup 2} could be observed. - Highlights: Black-Right-Pointing-Pointer We introduce a simplified architecture for phosphorescent white organic light-emitting device. Black-Right-Pointing-Pointer The key concept of device fabrication is combination of doped blue emissive layer (EML) with non-doped ultra-thin yellow EML. Black-Right-Pointing-Pointer Doping concentration of the blue EML and thickness of the yellow EML are sequentially adjusted. Black-Right-Pointing-Pointer High device performance is achieved due to improved charge carrier balance as well as two parallel emission mechanisms in the EMLs.

  11. A Witricity-Based High-Power Device for Wireless Charging of Electric Vehicles

    Directory of Open Access Journals (Sweden)

    Zhongyu Dai

    2017-03-01

    Full Text Available In this paper, a Witricity-based high-power device is proposed for wireless charging of electric vehicles. According to the specific requirements of three-stage charging for electric vehicles, four compensation modes of the Witricity system are analyzed by the Loosely Coupled Theory among transformer coils and the Substitution Theorem in circuit theory. In addition, when combining voltage withstand levels, the current withstand capability, the switching frequency of electronic switching tubes, and the features of the resonant circuit, the series-parallel (SP compensation mode is selected as the best compensation mode for matching the capacitor of the system. The performances of coils with different ferrite core arrangements are compared by simulations and models. The feasibility of the system is verified theoretically and the system functions are evaluated by the joint simulation of Simplorer and Maxwell. Finally, a Witricity-based high-power device is proposed as designed, and the correctness of theoretical analyses and simulation results are verified.

  12. Device and method for enhanced collection and assay of chemicals with high surface area ceramic

    Science.gov (United States)

    Addleman, Raymond S.; Li, Xiaohong Shari; Chouyyok, Wilaiwan; Cinson, Anthony D.; Bays, John T.; Wallace, Krys

    2016-02-16

    A method and device for enhanced capture of target analytes is disclosed. This invention relates to collection of chemicals for separations and analysis. More specifically, this invention relates to a solid phase microextraction (SPME) device having better capability for chemical collection and analysis. This includes better physical stability, capacity for chemical collection, flexible surface chemistry and high affinity for target analyte.

  13. Use of high current density superconducting coils in fusion devices

    International Nuclear Information System (INIS)

    Green, M.A.

    1979-11-01

    Superconducting magnets will play an important role in fusion research in years to come. The magnets which are currently proposed for fusion research use the concept of cryostability to insure stable operation of the superconducting coils. This paper proposes the use of adiabatically stable high current density superconducting coils in some types of fusion devices. The advantages of this approach are much lower system cold mass, enhanced cryogenic safety, increased access to the plasma and lower cost

  14. Impact of Tricuspid Valve Surgery at the Time of Left Ventricular Assist Device Insertion on Postoperative Outcomes

    OpenAIRE

    Dunlay, Shannon M.; Deo, Salil V.; Park, Soon J.

    2015-01-01

    Tricuspid regurgitation (TR) is common in patients with heart failure undergoing left ventricular assist device (LVAD) implantation. Whether the TR should be surgically managed at the time of LVAD surgery is controversial.

  15. High School Pupils' Attitudes and Self-Efficacy of Using Mobile Devices

    Science.gov (United States)

    Nikolopoulou, Kleopatra; Gialamas, Vasilis

    2017-01-01

    This paper regards a study aiming to investigate junior high school pupils' attitudes and self-efficacy of using mobile devices. A 25-item questionnaire was administered to 260 pupils aged 12-15 years old, in Greece. Pupils' attitudes were positive, and four factors were extracted, "perceived usefulness", "affection",…

  16. Reactor water clean-up device

    International Nuclear Information System (INIS)

    Tanaka, Koji; Egashira, Yasuo; Shimada, Fumie; Igarashi, Noboru.

    1983-01-01

    Purpose: To save a low temperature reactor water clean-up system indispensable so far and significantly simplify the system by carrying out the reactor water clean-up solely in a high temperature reactor water clean-up system. Constitution: The reactor water clean-up device comprises a high temperature clean-up pump and a high temperature adsorption device for inorganic adsorbents. The high temperature adsorption device is filled with amphoteric ion adsorbing inorganic adsorbents, or amphoteric ion adsorbing inorganic adsorbents and anionic adsorbing inorganic adsorbents. The reactor water clean-up device introduces reactor water by the high temperature clean-up pump through a recycling system to the high temperature adsorption device for inorganic adsorbents. Since cations such as cobalt ions and anions such as chlorine ions in the reactor water are simultaneously removed in the device, a low temperature reactor water clean-up system which has been indispensable so far can be saved to realize the significant simplification for the entire system. (Seki, T.)

  17. The association between ownership of common household devices and obesity and diabetes in high, middle and low income countries.

    Science.gov (United States)

    Lear, Scott A; Teo, Koon; Gasevic, Danijela; Zhang, Xiaohe; Poirier, Paul P; Rangarajan, Sumathy; Seron, Pamela; Kelishadi, Roya; Tamil, Azmi Mohd; Kruger, Annamarie; Iqbal, Romaina; Swidan, Hani; Gómez-Arbeláez, Diego; Yusuf, Rita; Chifamba, Jephat; Kutty, V Raman; Karsıdag, Kubilay; Kumar, Rajesh; Li, Wei; Szuba, Andrzej; Avezum, Alvaro; Diaz, Rafael; Anand, Sonia S; Rosengren, Annika; Yusuf, Salim

    2014-03-04

    Household devices (e.g., television, car, computer) are common in high income countries, and their use has been linked to obesity and type 2 diabetes mellitus. We hypothesized that device ownership is associated with obesity and diabetes and that these effects are explained through reduced physical activity, increased sitting time and increased energy intake. We performed a cross-sectional analysis using data from the Prospective Urban Rural Epidemiology study involving 153,996 adults from high, upper-middle, lower-middle and low income countries. We used multilevel regression models to account for clustering at the community and country levels. Ownership of a household device increased from low to high income countries (4% to 83% for all 3 devices) and was associated with decreased physical activity and increased sitting, dietary energy intake, body mass index and waist circumference. There was an increased odds of obesity and diabetes with the ownership of any 1 household device compared to no device ownership (obesity: odds ratio [OR] 1.43, 95% confidence interval [CI] 1.32-1.55; diabetes: OR 1.38, 95% CI 1.28-1.50). Ownership of a second device increased the odds further but ownership of a third device did not. Subsequent adjustment for lifestyle factors modestly attenuated these associations. Of the 3 devices, ownership of a television had the strongest association with obesity (OR 1.39, 95% CI 1.29-1.49) and diabetes (OR 1.33, 95% CI 1.23-1.44). When stratified by country income level, the odds of obesity and diabetes when owning all 3 devices was greatest in low income countries (obesity: OR 3.15, 95% CI 2.33-4.25; diabetes: OR 1.97, 95% CI 1.53-2.53) and decreased through country income levels such that we did not detect an association in high income countries. The ownership of household devices increased the likelihood of obesity and diabetes, and this was mediated in part by effects on physical activity, sitting time and dietary energy intake. With

  18. Highly tunable local gate controlled complementary graphene device performing as inverter and voltage controlled resistor.

    Science.gov (United States)

    Kim, Wonjae; Riikonen, Juha; Li, Changfeng; Chen, Ya; Lipsanen, Harri

    2013-10-04

    Using single-layer CVD graphene, a complementary field effect transistor (FET) device is fabricated on the top of separated back-gates. The local back-gate control of the transistors, which operate with low bias at room temperature, enables highly tunable device characteristics due to separate control over electrostatic doping of the channels. Local back-gating allows control of the doping level independently of the supply voltage, which enables device operation with very low VDD. Controllable characteristics also allow the compensation of variation in the unintentional doping typically observed in CVD graphene. Moreover, both p-n and n-p configurations of FETs can be achieved by electrostatic doping using the local back-gate. Therefore, the device operation can also be switched from inverter to voltage controlled resistor, opening new possibilities in using graphene in logic circuitry.

  19. Diamond semiconducting devices

    International Nuclear Information System (INIS)

    Polowczyk, M.; Klugmann, E.

    1999-01-01

    Many efforts to apply the semiconducting diamond for construction of electronic elements: resistors, thermistors, photoresistors, piezoresistors, hallotrons, pn diodes, Schottky diodes, IMPATT diodes, npn transistor, MESFETs and MISFETs are reviewed. Considering the possibilities of acceptor and donor doping, electrical resistivity and thermal conductivity of diamond as well as high electric-field breakdown points, that diamond devices could be used at about 30-times higher frequency and more then 8200 times power than silicon devices. Except that, due to high heat resistant of diamond, it is concluded that diamond devices can be used in environment at high temperature, range of 600 o C. (author)

  20. High-speed high-efficiency 500-W cw CO2 laser hermetization of metal frames of microelectronics devices

    Science.gov (United States)

    Levin, Andrey V.

    1996-04-01

    High-speed, efficient method of laser surface treatment has been developed using (500 W) cw CO2 laser. The principal advantages of CO2 laser surface treatment in comparison with solid state lasers are the basis of the method. It has been affirmed that high efficiency of welding was a consequence of the fundamental properties of metal-IR-radiation (10,6 mkm) interaction. CO2 laser hermetization of metal frames of microelectronic devices is described as an example of the proposed method application.

  1. High performance superconducting devices enabled by three dimensionally ordered nanodots and/or nanorods

    Science.gov (United States)

    Goyal, Amit

    2013-09-17

    Novel articles and methods to fabricate same with self-assembled nanodots and/or nanorods of a single or multicomponent material within another single or multicomponent material for use in electrical, electronic, magnetic, electromagnetic and electrooptical devices is disclosed. Self-assembled nanodots and/or nanorods are ordered arrays wherein ordering occurs due to strain minimization during growth of the materials. A simple method to accomplish this when depositing in-situ films is also disclosed. Device applications of resulting materials are in areas of superconductivity, photovoltaics, ferroelectrics, magnetoresistance, high density storage, solid state lighting, non-volatile memory, photoluminescence, thermoelectrics and in quantum dot lasers.

  2. A Device for Automatically Measuring and Supervising the Critical Care Patient’S Urine Output

    Directory of Open Access Journals (Sweden)

    Roemi Fernández

    2010-01-01

    Full Text Available Critical care units are equipped with commercial monitoring devices capable of sensing patients’ physiological parameters and supervising the achievement of the established therapeutic goals. This avoids human errors in this task and considerably decreases the workload of the healthcare staff. However, at present there still is a very relevant physiological parameter that is measured and supervised manually by the critical care units’ healthcare staff: urine output. This paper presents a patent-pending device capable of automatically recording and supervising the urine output of a critical care patient. A high precision scale is used to measure the weight of a commercial urine meter. On the scale’s pan there is a support frame made up of Bosch profiles that isolates the scale from force transmission from the patient’s bed, and guarantees that the urine flows properly through the urine meter input tube. The scale’s readings are sent to a PC via Bluetooth where an application supervises the achievement of the therapeutic goals. The device is currently undergoing tests at a research unit associated with the University Hospital of Getafe in Spain.

  3. Surgical virtual reality - highlights in developing a high performance surgical haptic device.

    Science.gov (United States)

    Custură-Crăciun, D; Cochior, D; Constantinoiu, S; Neagu, C

    2013-01-01

    Just like simulators are a standard in aviation and aerospace sciences, we expect for surgical simulators to soon become a standard in medical applications. These will correctly instruct future doctors in surgical techniques without there being a need for hands on patient instruction. Using virtual reality by digitally transposing surgical procedures changes surgery in are volutionary manner by offering possibilities for implementing new, much more efficient, learning methods, by allowing the practice of new surgical techniques and by improving surgeon abilities and skills. Perfecting haptic devices has opened the door to a series of opportunities in the fields of research,industry, nuclear science and medicine. Concepts purely theoretical at first, such as telerobotics, telepresence or telerepresentation,have become a practical reality as calculus techniques, telecommunications and haptic devices evolved,virtual reality taking a new leap. In the field of surgery barrier sand controversies still remain, regarding implementation and generalization of surgical virtual simulators. These obstacles remain connected to the high costs of this yet fully sufficiently developed technology, especially in the domain of haptic devices. Celsius.

  4. Chromatic Modulator for High Resolution CCD or APS Devices

    Science.gov (United States)

    Hartley, Frank T. (Inventor); Hull, Anthony B. (Inventor)

    2003-01-01

    A system for providing high-resolution color separation in electronic imaging. Comb drives controllably oscillate a red-green-blue (RGB) color strip filter system (or otherwise) over an electronic imaging system such as a charge-coupled device (CCD) or active pixel sensor (APS). The color filter is modulated over the imaging array at a rate three or more times the frame rate of the imaging array. In so doing, the underlying active imaging elements are then able to detect separate color-separated images, which are then combined to provide a color-accurate frame which is then recorded as the representation of the recorded image. High pixel resolution is maintained. Registration is obtained between the color strip filter and the underlying imaging array through the use of electrostatic comb drives in conjunction with a spring suspension system.

  5. 16 CFR Figures 1 and 2 to Part 1204 - Suggested Instrumentation for Current Monitoring Device and High Voltage Facility

    Science.gov (United States)

    2010-01-01

    ... 16 Commercial Practices 2 2010-01-01 2010-01-01 false Suggested Instrumentation for Current Monitoring Device and High Voltage Facility 1 Figures 1 and 2 to Part 1204 Commercial Practices CONSUMER... Instrumentation for Current Monitoring Device and High Voltage Facility EC03OC91.008 ...

  6. Maximum Efficiency of Thermoelectric Heat Conversion in High-Temperature Power Devices

    Directory of Open Access Journals (Sweden)

    V. I. Khvesyuk

    2016-01-01

    Full Text Available Modern trends in development of aircraft engineering go with development of vehicles of the fifth generation. The features of aircrafts of the fifth generation are motivation to use new high-performance systems of onboard power supply. The operating temperature of the outer walls of engines is of 800–1000 K. This corresponds to radiation heat flux of 10 kW/m2 . The thermal energy including radiation of the engine wall may potentially be converted into electricity. The main objective of this paper is to analyze if it is possible to use a high efficiency thermoelectric conversion of heat into electricity. The paper considers issues such as working processes, choice of materials, and optimization of thermoelectric conversion. It presents the analysis results of operating conditions of thermoelectric generator (TEG used in advanced hightemperature power devices. A high-temperature heat source is a favorable factor for the thermoelectric conversion of heat. It is shown that for existing thermoelectric materials a theoretical conversion efficiency can reach the level of 15–20% at temperatures up to 1500 K and available values of Ioffe parameter being ZT = 2–3 (Z is figure of merit, T is temperature. To ensure temperature regime and high efficiency thermoelectric conversion simultaneously it is necessary to have a certain match between TEG power, temperature of hot and cold surfaces, and heat transfer coefficient of the cooling system. The paper discusses a concept of radiation absorber on the TEG hot surface. The analysis has demonstrated a number of potentialities for highly efficient conversion through using the TEG in high-temperature power devices. This work has been implemented under support of the Ministry of Education and Science of the Russian Federation; project No. 1145 (the programme “Organization of Research Engineering Activities”.

  7. Simple Check Valves for Microfluidic Devices

    Science.gov (United States)

    Willis, Peter A.; Greer, Harold F.; Smith, J. Anthony

    2010-01-01

    A simple design concept for check valves has been adopted for microfluidic devices that consist mostly of (1) deformable fluorocarbon polymer membranes sandwiched between (2) borosilicate float glass wafers into which channels, valve seats, and holes have been etched. The first microfluidic devices in which these check valves are intended to be used are micro-capillary electrophoresis (microCE) devices undergoing development for use on Mars in detecting compounds indicative of life. In this application, it will be necessary to store some liquid samples in reservoirs in the devices for subsequent laboratory analysis, and check valves are needed to prevent cross-contamination of the samples. The simple check-valve design concept is also applicable to other microfluidic devices and to fluidic devices in general. These check valves are simplified microscopic versions of conventional rubber- flap check valves that are parts of numerous industrial and consumer products. These check valves are fabricated, not as separate components, but as integral parts of microfluidic devices. A check valve according to this concept consists of suitably shaped portions of a deformable membrane and the two glass wafers between which the membrane is sandwiched (see figure). The valve flap is formed by making an approximately semicircular cut in the membrane. The flap is centered over a hole in the lower glass wafer, through which hole the liquid in question is intended to flow upward into a wider hole, channel, or reservoir in the upper glass wafer. The radius of the cut exceeds the radius of the hole by an amount large enough to prevent settling of the flap into the hole. As in a conventional rubber-flap check valve, back pressure in the liquid pushes the flap against the valve seat (in this case, the valve seat is the adjacent surface of the lower glass wafer), thereby forming a seal that prevents backflow.

  8. Heterostructures and quantum devices

    CERN Document Server

    Einspruch, Norman G

    1994-01-01

    Heterostructure and quantum-mechanical devices promise significant improvement in the performance of electronic and optoelectronic integrated circuits (ICs). Though these devices are the subject of a vigorous research effort, the current literature is often either highly technical or narrowly focused. This book presents heterostructure and quantum devices to the nonspecialist, especially electrical engineers working with high-performance semiconductor devices. It focuses on a broad base of technical applications using semiconductor physics theory to develop the next generation of electrical en

  9. Planar junctionless phototransistor: A potential high-performance and low-cost device for optical-communications

    Science.gov (United States)

    Ferhati, H.; Djeffal, F.

    2017-12-01

    In this paper, a new junctionless optical controlled field effect transistor (JL-OCFET) and its comprehensive theoretical model is proposed to achieve high optical performance and low cost fabrication process. Exhaustive study of the device characteristics and comparison between the proposed junctionless design and the conventional inversion mode structure (IM-OCFET) for similar dimensions are performed. Our investigation reveals that the proposed design exhibits an outstanding capability to be an alternative to the IM-OCFET due to the high performance and the weak signal detection benefit offered by this design. Moreover, the developed analytical expressions are exploited to formulate the objective functions to optimize the device performance using Genetic Algorithms (GAs) approach. The optimized JL-OCFET not only demonstrates good performance in terms of derived drain current and responsivity, but also exhibits superior signal to noise ratio, low power consumption, high-sensitivity, high ION/IOFF ratio and high-detectivity as compared to the conventional IM-OCFET counterpart. These characteristics make the optimized JL-OCFET potentially suitable for developing low cost and ultrasensitive photodetectors for high-performance and low cost inter-chips data communication applications.

  10. Synthesis of structure of device for the technical diagnosticating of high-voltage discharge

    OpenAIRE

    Грабко, В. В.; Ковальчук, Венедикт Петрович

    2010-01-01

    The paper presents a device for control of the technical state of high-voltage discharge, which allows, not disconnecting him from power grid, to take into account a size and duration of interconnect current of discharge, and also size of remaining voltage.

  11. High Pressure Soxhlet Type Leachability testing device and leaching test of simulated high-level waste glass at high temperature

    International Nuclear Information System (INIS)

    Senoo, Muneaki; Banba, Tsunetaka; Tashiro, Shingo; Shimooka, Kenji; Araki, Kunio

    1979-11-01

    A High Pressure Soxhlet Type Leachability Testing Device (HIPSOL) was developed to evaluate long-period stability of high-level waste (HLW) solids. For simulated HLW solids, temperature dependency of the leachability was investigated at higher temperatures from 100 0 C to 300 0 C at 80 atm. Leachabilities of cesium and sodium at 295 0 C were 20 and 7 times higher than at 100 0 C, respectively. In the repository, the temperatures around solidified products may be hundred 0 C. It is essential to test them at such elevated temperatures. HIPSOL is also usable for accelerated test to evaluate long-period leaching behavior of HLW products. (author)

  12. Rosuvastatin and cardiovascular events in patients undergoing hemodialysis

    DEFF Research Database (Denmark)

    Fellström, Bengt C; Jardine, Alan G; Schmieder, Roland E

    2009-01-01

    . Secondary end points included death from all causes and individual cardiac and vascular events. RESULTS: After 3 months, the mean reduction in low-density lipoprotein (LDL) cholesterol levels was 43% in patients receiving rosuvastatin, from a mean baseline level of 100 mg per deciliter (2.6 mmol per liter......BACKGROUND: Statins reduce the incidence of cardiovascular events in patients at high cardiovascular risk. However, a benefit of statins in such patients who are undergoing hemodialysis has not been proved. METHODS: We conducted an international, multicenter, randomized, double-blind, prospective...... trial involving 2776 patients, 50 to 80 years of age, who were undergoing maintenance hemodialysis. We randomly assigned patients to receive rosuvastatin, 10 mg daily, or placebo. The combined primary end point was death from cardiovascular causes, nonfatal myocardial infarction, or nonfatal stroke...

  13. Particle-Based Microfluidic Device for Providing High Magnetic Field Gradients

    Science.gov (United States)

    Lin, Adam Y. (Inventor); Wong, Tak S. (Inventor)

    2013-01-01

    A microfluidic device for manipulating particles in a fluid has a device body that defines a main channel therein, in which the main channel has an inlet and an outlet. The device body further defines a particulate diverting channel therein, the particulate diverting channel being in fluid connection with the main channel between the inlet and the outlet of the main channel and having a particulate outlet. The microfluidic device also has a plurality of microparticles arranged proximate or in the main channel between the inlet of the main channel and the fluid connection of the particulate diverting channel to the main channel. The plurality of microparticles each comprises a material in a composition thereof having a magnetic susceptibility suitable to cause concentration of magnetic field lines of an applied magnetic field while in operation. A microfluidic particle-manipulation system has a microfluidic particle-manipulation device and a magnet disposed proximate the microfluidic particle-manipulation device.

  14. Micro-patterned agarose gel devices for single-cell high-throughput microscopy of E. coli cells.

    Science.gov (United States)

    Priest, David G; Tanaka, Nobuyuki; Tanaka, Yo; Taniguchi, Yuichi

    2017-12-21

    High-throughput microscopy of bacterial cells elucidated fundamental cellular processes including cellular heterogeneity and cell division homeostasis. Polydimethylsiloxane (PDMS)-based microfluidic devices provide advantages including precise positioning of cells and throughput, however device fabrication is time-consuming and requires specialised skills. Agarose pads are a popular alternative, however cells often clump together, which hinders single cell quantitation. Here, we imprint agarose pads with micro-patterned 'capsules', to trap individual cells and 'lines', to direct cellular growth outwards in a straight line. We implement this micro-patterning into multi-pad devices called CapsuleHotel and LineHotel for high-throughput imaging. CapsuleHotel provides ~65,000 capsule structures per mm 2 that isolate individual Escherichia coli cells. In contrast, LineHotel provides ~300 line structures per mm that direct growth of micro-colonies. With CapsuleHotel, a quantitative single cell dataset of ~10,000 cells across 24 samples can be acquired and analysed in under 1 hour. LineHotel allows tracking growth of > 10 micro-colonies across 24 samples simultaneously for up to 4 generations. These easy-to-use devices can be provided in kit format, and will accelerate discoveries in diverse fields ranging from microbiology to systems and synthetic biology.

  15. Control Board Digital Interface Input Devices – Touchscreen, Trackpad, or Mouse?

    Energy Technology Data Exchange (ETDEWEB)

    Thomas A. Ulrich; Ronald L. Boring; Roger Lew

    2015-08-01

    The authors collaborated with a power utility to evaluate input devices for use in the human system interface (HSI) for a new digital Turbine Control System (TCS) at a nuclear power plant (NPP) undergoing a TCS upgrade. A standalone dynamic software simulation of the new digital TCS and a mobile kiosk were developed to conduct an input device study to evaluate operator preference and input device effectiveness. The TCS software presented the anticipated HSI for the TCS and mimicked (i.e., simulated) the turbine systems’ responses to operator commands. Twenty-four licensed operators from the two nuclear power units participated in the study. Three input devices were tested: a trackpad, mouse, and touchscreen. The subjective feedback from the survey indicates the operators preferred the touchscreen interface. The operators subjectively rated the touchscreen as the fastest and most comfortable input device given the range of tasks they performed during the study, but also noted a lack of accuracy for selecting small targets. The empirical data suggest the mouse input device provides the most consistent performance for screen navigation and manipulating on screen controls. The trackpad input device was both empirically and subjectively found to be the least effective and least desired input device.

  16. Perioperative mortality in cats and dogs undergoing spay or castration at a high-volume clinic.

    Science.gov (United States)

    Levy, J K; Bard, K M; Tucker, S J; Diskant, P D; Dingman, P A

    2017-06-01

    High volume spay-neuter (spay-castration) clinics have been established to improve population control of cats and dogs to reduce the number of animals admitted to and euthanazed in animal shelters. The rise in the number of spay-neuter clinics in the USA has been accompanied by concern about the quality of animal care provided in high volume facilities, which focus on minimally invasive, time saving techniques, high throughput and simultaneous management of multiple animals under various stages of anesthesia. The aim of this study was to determine perioperative mortality for cats and dogs in a high volume spay-neuter clinic in the USA. Electronic medical records and a written mortality log were used to collect data for 71,557 cats and 42,349 dogs undergoing spay-neuter surgery from 2010 to 2016 at a single high volume clinic in Florida. Perioperative mortality was defined as deaths occurring in the 24h period starting with the administration of the first sedation or anesthetic drugs. Perioperative mortality was reported for 34 cats and four dogs for an overall mortality of 3.3 animals/10,000 surgeries (0.03%). The risk of mortality was more than twice as high for females (0.05%) as for males (0.02%) (P=0.008) and five times as high for cats (0.05%) as for dogs (0.009%) (P=0.0007). High volume spay-neuter surgery was associated with a lower mortality rate than that previously reported in low volume clinics, approaching that achieved in human surgery. This is likely to be due to the young, healthy population of dogs and cats, and the continuous refinement of techniques based on experience and the skills and proficiency of teams that specialize in a limited spectrum of procedures. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. Analysis of emboli during carotid stenting with distal protection device.

    Science.gov (United States)

    Chen, Chin-I; Iguchi, Yasuyuki; Garami, Zsolt; Malkoff, Marc D; Smalling, Richard W; Campbell, Morgan S; Alexandrov, Andrei V

    2006-01-01

    The newly developed multi-frequency transcranial Doppler (TCD) is able to differentiate gaseous from solid emboli. Our goal was to apply this technology to initially characterize emboli detected during carotid stenting with distal protection. Patients undergoing carotid angiography and stenting were monitored with 2-2.5 MHz TCD (Embo-Dop, DWL) over the middle cerebral artery unilateral to stent deployment. Sonographers insured optimal signal recordings during the procedures. Automated emboli detection and classification software (MultiXLab version 2.0) was applied for offline count and analysis. Monitoring using the Filter Wire EX (Boston Scientific) and ACCUNET system (Guidant Corporation) was performed. A total of 9,649 embolic signals were detected during 11 angiographic and 10 stenting procedures. An observer confirmed the signals using the International Consensus definition. Automated software classified these events into 5,900 gaseous and 3,749 solid emboli. During contrast injections without the protection device, 1,013 emboli were detected with 28% of these being solid. With deployment of the distal protection device, 8,636 emboli were found with 40% being solid (p protection device, 7,395 emboli with 42% solids were detected (p protection device still deployed, yielded 1,241 emboli with 31% solids (NS). Only 1 patient developed transient hemiparesthesia during ballooning that reduced the flow velocity to zero for 14 s. Neither gaseous nor solid emboli resulted in a mean flow velocity decrease or clinical symptoms. Microembolization frequently occurs during stenting even with deployment of the distal protection device. More solid emboli are seen during manipulations associated with lesion crossing. Although novel TCD methods yield a high frequency of embolic signals, further validation of this technique to determine the true nature, size, and number of emboli is needed.

  18. The Meaning and Experience of Patients Undergoing Rectal High-Dose-Rate Brachytherapy.

    Science.gov (United States)

    Perez, Samara; Néron, Sylvain; Benc, Renata; Rosberger, Zeev; Vuong, Té

    2016-01-01

    High-dose-rate (HDR) brachytherapy is a precise form of radiation therapy that targets cancerous tumors by directly applying the radiation source at the site or directly next to the tumor. Patients often experience but underreport pain and anxiety related to cancer treatments. At present, there is no research available concerning the pervasiveness and intensity of patients' pain and anxiety during rectal brachytherapy. The aim of this study was to examine patients' thoughts, emotions, coping strategies, physical sensations, and needs during rectal HDR brachytherapy treatment. Twenty-five patients with rectal cancer were interviewed using a semi-structured qualitative interview following the completion of their brachytherapy treatment delivered at a Montreal-based hospital in Quebec, Canada. The experiences of pain and discomfort varied greatly between patients and were linked to the meaning patients attributed to the treatment itself, sense of time, the body's lithotomic position, insertion of the treatment applicator, and the patients' sense of agency and empowerment during the procedure. Patients drew upon a variety of internal and external resources to help them cope with discomfort. Staff need to know about the variation in the physical and emotional experiences of patients undergoing this treatment. Clinical teams can tailor their procedural behavior (eg, using certain language, psychosocial interventions) according to patients' needs to increase patients' comfort and ultimately improve their experience of HDR rectal brachytherapy.

  19. Device for high-temperature X-ray diffraction analysis. Ustrojstvo dlya vysokotemperaturnogo rentgenostrukturnogo analiza

    Energy Technology Data Exchange (ETDEWEB)

    Epifanov, V G; Zavilinskij, A V; Pet' kov, V V; Polenur, A V

    1975-01-07

    Device for high-temperature X-ray diffraction analysis, containing a vacuum chamber with a window for X-ray transit, in which sample- and standard-holders, heater, thermal shields and means for standard and sample temperature measurement are located, is proposed. In order to increase the working temperature level and the structural change detection accuracy the heater is located between the sample- and standard-holders. The standard-holder is linked with the mechanism of control of its position in relation to the heater. The device is intended for investigating phase transformations by differential thermal analysis method with the simultaneous diffraction pattern detection using X-ray diffractometry method.

  20. Simulation of photons from plasmas for the applications to display devices

    Science.gov (United States)

    Lee, Hae June; Yoon, Hyun Jin; Lee, Jae Koo

    2007-07-01

    Numerical modeling of the photon transport of the ultraviolet (UV) and the visible lights are presented for plasma based display devices. The transport of UV lights which undergo resonance trapping by ground state atoms is solved by using the Holstein equation. After the UV lights are transformed to visible lights at the phosphor surfaces, the visible lights experience complicated traces inside the cell and finally are emitted toward the viewing window after having some power loss within the cell. A three-dimensional ray trace of the visible lights is calculated with a radiosity model. These simulations for the photons strengthen plasma discharge modeling for the application to display devices.

  1. Design of a test device for subjecting materials to high strain rates: with application in nuclear area

    Energy Technology Data Exchange (ETDEWEB)

    Todesco, Sergio R.; Mucsi, Cristiano S.; Rossi, Jesualdo L., E-mail: sergio.todesco@usp.br, E-mail: csmucsi@ipen.br, E-mail: jelrossi@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2015-07-01

    This paper presents a design of a device to gather characteristic data of materials subjected to high strain rates, this device named after the eminent English engineer Sir Bertram Hopkinson 'Split Hopkinson Pressure Bar', from here will be designated SHPB. More specifically, this work is inseparably linked to the development of packing for transportation of highly radioactive substances as a part to the general scope of a CAPES project in partnership with the CCTM Materials Department of IPEN, Institute of Energy and Nuclear Research, linked to the University of Sao Paulo. The development of the device is part of a scope, and collection of data necessary for the design and construction of this packing. The SHPB device can be divided into two parts, the first part concerning the mechanical design. The second, data collection that is indeed the challenging part of the device, and proper tests. The present paper, specifically, will only deals with the mechanical design of the device, importantly, divided into two parts, the size of the bars, which are the impact bar, the input bar, and the output bar, and the size of the impact device. The sizing of the bars involve knowledge of the concept of elastic waves in solid media for the length of the bars to serve as a wave-guide, which will cause a deformation of the specimen, and enables recording of these waves for data analysis. The impact device must be robust enough to produce the stress wave to deform the specimen, but not to plastically deform the bars, which have to continue throughout the test within the elastic range. (author)

  2. Design of a test device for subjecting materials to high strain rates: with application in nuclear area

    International Nuclear Information System (INIS)

    Todesco, Sergio R.; Mucsi, Cristiano S.; Rossi, Jesualdo L.

    2015-01-01

    This paper presents a design of a device to gather characteristic data of materials subjected to high strain rates, this device named after the eminent English engineer Sir Bertram Hopkinson 'Split Hopkinson Pressure Bar', from here will be designated SHPB. More specifically, this work is inseparably linked to the development of packing for transportation of highly radioactive substances as a part to the general scope of a CAPES project in partnership with the CCTM Materials Department of IPEN, Institute of Energy and Nuclear Research, linked to the University of Sao Paulo. The development of the device is part of a scope, and collection of data necessary for the design and construction of this packing. The SHPB device can be divided into two parts, the first part concerning the mechanical design. The second, data collection that is indeed the challenging part of the device, and proper tests. The present paper, specifically, will only deals with the mechanical design of the device, importantly, divided into two parts, the size of the bars, which are the impact bar, the input bar, and the output bar, and the size of the impact device. The sizing of the bars involve knowledge of the concept of elastic waves in solid media for the length of the bars to serve as a wave-guide, which will cause a deformation of the specimen, and enables recording of these waves for data analysis. The impact device must be robust enough to produce the stress wave to deform the specimen, but not to plastically deform the bars, which have to continue throughout the test within the elastic range. (author)

  3. Evaluation of self-esteem in cancer patients undergoing chemotherapy treatment

    Directory of Open Access Journals (Sweden)

    Marilia Aparecida Carvalho Leite

    2015-12-01

    Full Text Available Objective: to evaluate the self-esteem of cancer patients undergoing chemotherapy. Method: descriptive analytical cross-sectional study with a quantitative approach. Around 156 patients that attended an oncology unit of a mid-sized hospital participated in the study. Results: we found a higher frequency of patients with high self-esteem, but some of them showed average or low self-esteem. The scale showed a Cronbach's alpha value of 0.746, by considering its acceptable internal consistency for the evaluated items. No independent variables showed significant associations with self-esteem. Conclusion: the cancer patients evaluated have presented high self-esteem; thus, it becomes crucial for nursing to plan the assistance of patients undergoing chemotherapy treatments, which enables actions and strategies that meet their physical and psychosocial conditions, aiming to maintain and rehabilitate these people's emotional aspects.

  4. Determining Studies Conducted upon Individuals with Autism Spectrum Disorder Using High-Tech Devices

    Science.gov (United States)

    Eliçin, Özge; Kaya, Ali

    2017-01-01

    This study explores 67 experimental research articles written about children with Autism Spectrum Disorder using high-tech devices. The studies in this research were accessed through EBSCO, Academic Search Complete, ERIC, and Uludag University online search engines using keywords such as "autism and technology", "autism and…

  5. Development of a high-resolution apparatus to monitor physiological state of a person undergoing extreme conditions

    Directory of Open Access Journals (Sweden)

    Kodermyatov Radik

    2016-01-01

    Full Text Available The present research has shown that ECG recordings and parameters of the body functional state are crucial for all kinds of the astronaut pre-flight preparations (centrifuge, thermal chamber, pressure chamber, pressure chamber with special equipment. It is, therefore, important to develop methods and tools for early detection of the preclinical forms of the functional state disorders in patients undergoing high-intensity loads of mixed character. The method based on the hardware-software compleх (HSC with nanosensors of high resolution has been proposed to measure the electrophysiological characteristics and bioelectrical impedance of the body tissues directly exposed to loading. The hardware-software compleх is subjected to clinical trials in Tomsk Research Institute for Cardiology. The obtained results show that the use of nanosensors of high resolution in the HSC without standard filters allows elimination of the power-line interference in ECG recordings. Monitoring of the tissue bioimpedance parameters under test loads enables the detection of preclinical (latent forms of various diseases. After clinical trials in Tomsk Institute for Cardiology the developed apparatus will be proposed for in-depth study of the cardiovascular system and the functional state of the body of astronauts and other persons exposed to extreme loads.

  6. On-Chip Electrolytic Chemistry for the Tuning of Graphene Devices

    Science.gov (United States)

    Schmucker, Scott; Ruppalt, Laura; Culbertson, James; Do, Jae Won; Lyding, Joseph; Robinson, Jeremy; Cress, Cory

    2015-03-01

    The inherent interfacial nature of two-dimensional materials has motivated the tuning of these films by choice of substrate or chemical functionalization. Such parameters are generally selected during fabrication, and therefore remain static during device operation. However, the possibility of dynamic chemistry in a tunable solid-state system will enable the development of new devices which fully leverage the rich chemistry of graphenic materials. Here, we fabricate a novel device for localized, dynamic doping and functionalization of graphene that is compatible with CMOS processing. The device is enabled by a top-gated, solid electrochemical cell designed with calcium fluoride (CaF2) substituting the oxide of a traditional MOSFET. When the CaF2 is gated, F flows from cathode to anode, segregating Ca and F. In this work, one electrode is graphene. When saturated with fluorine, graphene undergoes covalent modification, becoming a wide-bandgap semiconductor. In contrast, when functionalized with calcium or dilute fluorine, graphene is electron or hole doped, respectively. With transport, Raman, and XPS, we demonstrate this lithographically localized and reversible modulation of graphene's electronic and chemical character.

  7. An Automatic Occlusion Device for Remote Control of Tumor Tissue Ischemia

    Science.gov (United States)

    El-Dahdah, Hamid; Wang, Bei; He, Guanglong; Xu, Ronald X.

    2015-01-01

    We developed an automatic occlusion device for remote control of tumor tissue ischemia. The device consists of a flexible cannula encasing a shape memory alloy wire with its distal end connected to surgical suture. Regional tissue occlusion was tested on both the benchtop and the animal models. In the benchtop test, the occlusion device introduced quantitative and reproducible changes of blood flow in a tissue simulating phantom embedding a vessel simulator. In the animal test, the device generated a cyclic pattern of reversible ischemia in the right hinder leg tissue of a black male C57BL/6 mouse. We also developed a multimodal detector that integrates near infrared spectroscopy and electron paramagnetic resonance spectroscopy for continuous monitoring of tumor tissue oxygenation, blood content, and oxygen tension changes. The multimodal detector was tested on a cancer xenograft nude mouse undergoing reversible tumor ischemia. The automatic occlusion device and the multi-modal detector can be potentially integrated for closed-loop feedback control of tumor tissue ischemia. Such an integrated occlusion device may be used in multiple clinical applications such as regional hypoperfusion control in tumor resection surgeries and thermal ablation processes. In addition, the proposed occlusion device can also be used as a research tool to understand tumor oxygen transport and hemodynamic characteristics. PMID:20082532

  8. High-damage-threshold static laser beam shaping using optically patterned liquid-crystal devices.

    Science.gov (United States)

    Dorrer, C; Wei, S K-H; Leung, P; Vargas, M; Wegman, K; Boulé, J; Zhao, Z; Marshall, K L; Chen, S H

    2011-10-15

    Beam shaping of coherent laser beams is demonstrated using liquid crystal (LC) cells with optically patterned pixels. The twist angle of a nematic LC is locally set to either 0 or 90° by an alignment layer prepared via exposure to polarized UV light. The two distinct pixel types induce either no polarization rotation or a 90° polarization rotation, respectively, on a linearly polarized optical field. An LC device placed between polarizers functions as a binary transmission beam shaper with a highly improved damage threshold compared to metal beam shapers. Using a coumarin-based photoalignment layer, various devices have been fabricated and tested, with a measured single-shot nanosecond damage threshold higher than 30 J/cm2.

  9. Transcatheter Aortic Valve Replacement With Early- and New-Generation Devices in Bicuspid Aortic Valve Stenosis

    DEFF Research Database (Denmark)

    Yoon, Sung Han; Lefèvre, Thierry; Ahn, Jung Ming

    2016-01-01

    Background Few studies have evaluated the clinical outcomes of transcatheter aortic valve replacement (TAVR) in patients with bicuspid aortic valve stenosis (AS). Particularly, limited data exist comparing the results of TAVR with new-generation devices versus early-generation devices.  Objectives...... This study sought to evaluate the clinical outcomes of TAVR for bicuspid AS with early- and new-generation devices.  Methods The Bicuspid TAVR Registry is an international multicenter study enrolling consecutive patients with bicuspid AS undergoing TAVR between April 2005 and May 2015.  Results Of 301...... patients, 199 patients (71.1%) were treated with early-generation devices (Sapien XT [Edwards Lifesciences Corporation, Irvine, California]: n = 87; CoreValve [Medtronic, Minneapolis, Minnesota]: n = 112) and 102 with new-generation devices (Sapien 3 [Edwards Lifesciences Corporation]: n = 91; Lotus...

  10. Linear devices in combined high-level radiation environments

    International Nuclear Information System (INIS)

    van Vonno, N.W.

    1987-01-01

    The design of precision analog integrated circuits for use in combined high-level radiation environments has traditionally been on a full-custom basis. The use of semicustom design methods has become prevalent in digital devices, with standard cell libraries and gate arrays readily available from multiple vendors. This paper addresses the application of semicustom design techniques to analog parts. In all cases the emphasis is on bipolar technology, since this provides an optimal combination of precision and radiation hardness. A mixed mode analog/digital (A/D) cell family for implementing semicustom designs is described, together with the fabrication process used. Specific processing and design methods are used to provide circuit hardness against neutron, total gamma dose, and transient gamma environments. Semicustom mixed analog/digital design is seen as an appropriate methodology for implementation of medium-performance mixed mode functions for radiation-hardened applications. This leads to trade-offs in process complexity and performance. Full custom design remains necessary for demanding applications such as high-speed A/D conversion and associated sample/hold functions. An A/D cell family optimized for hardness is described, together with the bipolar process used to implement it

  11. Experimental devices for the spatio-temporal characterization of femtosecond high-power laser chains

    International Nuclear Information System (INIS)

    Gallet, Valentin

    2014-01-01

    One of the advantages of high-power femtosecond lasers (TW-PW) is to obtain, at the focus of a focusing optic, very high intensities up to 10 22 W.cm -2 (i.e. an electric field of 2.7 PV.m -1 . Therefore, these lasers chains necessarily deliver beams with large diameter (up to 40 cm) and very short pulses (of the order of tens of femto-seconds). As a consequence, the spatial and temporal properties of the pulse are generally not independent. Such dependence, called spatial-temporal coupling has the effect of increasing the pulse duration and the size of the focal spot, which can lead to a significant reduction of the maximum intensity at the focus. Metrology devices commonly used on these high-power femtosecond lasers allow retrieving the spatial and temporal profiles of the pulse only in an independent manner. The aim of this thesis was to develop techniques for measuring spatio-temporal couplings in order to quantify their effect and correct them in order to obtain the maximum intensity at focus. First of all, we adapted an existing technique of spatio-temporal characterization to the measurement of TW lasers. To avoid the issues induced at the focus, such as those related to jittering, measurements were performed on the collimated beam. By adding a reference source to the original device, we managed to take into account the measurement artifacts due to thermal and mechanical variations affecting the interferometer. With this improvement, it was possible to reconstruct the complete spatio-temporal profile of the beam, particularly its wavefront. However, the limitations imposed by this technique led to the development of a new measurement device. Based on a cross-correlation, this technique consists of making the laser beam to interfere with a part of itself, small enough not to be spatio-temporally distorted. We have also implemented a variant of this device for a single-shot measurement along one transverse dimension of the pulse. Using these techniques, we

  12. Preprocedural High-Sensitivity Cardiac Troponin T and Clinical Outcomes in Patients With Stable Coronary Artery Disease Undergoing Elective Percutaneous Coronary Intervention.

    Science.gov (United States)

    Zanchin, Thomas; Räber, Lorenz; Koskinas, Konstantinos C; Piccolo, Raffaele; Jüni, Peter; Pilgrim, Thomas; Stortecky, Stefan; Khattab, Ahmed A; Wenaweser, Peter; Bloechlinger, Stefan; Moschovitis, Aris; Frenk, Andre; Moro, Christina; Meier, Bernhard; Fiedler, Georg M; Heg, Dik; Windecker, Stephan

    2016-06-01

    Cardiac troponin detected by new-generation, highly sensitive assays predicts clinical outcomes among patients with stable coronary artery disease (SCAD) treated medically. The prognostic value of baseline high-sensitivity cardiac troponin T (hs-cTnT) elevation in SCAD patients undergoing elective percutaneous coronary interventions is not well established. This study assessed the association of preprocedural levels of hs-cTnT with 1-year clinical outcomes among SCAD patients undergoing percutaneous coronary intervention. Between 2010 and 2014, 6974 consecutive patients were prospectively enrolled in the Bern Percutaneous Coronary Interventions Registry. Among patients with SCAD (n=2029), 527 (26%) had elevated preprocedural hs-cTnT above the upper reference limit of 14 ng/L. The primary end point, mortality within 1 year, occurred in 20 patients (1.4%) with normal hs-cTnT versus 39 patients (7.7%) with elevated baseline hs-cTnT (P<0.001). Patients with elevated hs-cTnT had increased risks of all-cause (hazard ratio 5.73; 95% confidence intervals 3.34-9.83; P<0.001) and cardiac mortality (hazard ratio 4.68; 95% confidence interval 2.12-10.31; P<0.001). Preprocedural hs-TnT elevation remained an independent predictor of 1-year mortality after adjustment for relevant risk factors, including age, sex, and renal failure (adjusted hazard ratio 2.08; 95% confidence interval 1.10-3.92; P=0.024). A graded mortality risk was observed across higher tertiles of elevated preprocedural hs-cTnT, but not among patients with hs-cTnT below the upper reference limit. Preprocedural elevation of hs-cTnT is observed in one fourth of SCAD patients undergoing elective percutaneous coronary intervention. Increased levels of preprocedural hs-cTnT are proportionally related to the risk of death and emerged as independent predictors of all-cause mortality within 1 year. URL: http://www.clinicaltrials.gov. Unique identifier: NCT02241291. © 2016 American Heart Association, Inc.

  13. Bipolar sealer device reduces blood loss and transfusion requirements in posterior spinal fusion for adolescent idiopathic scoliosis.

    Science.gov (United States)

    Gordon, Zachary L; Son-Hing, Jochen P; Poe-Kochert, Connie; Thompson, George H

    2013-01-01

    Reducing perioperative blood loss and transfusion requirements is important in the operative treatment of idiopathic scoliosis. This can be achieved with special frames, cell saver systems, pharmacologic aspects, and other techniques. Recently there has been interest in bipolar sealer devices as an adjunct to traditional monopolar electrocautery. However, there is limited information on this device in pediatric spinal deformity surgery. We reviewed our experience with this device in a setting of a standard institutional operative carepath. Perioperative blood loss and transfusion requirements of 50 consecutive patients with adolescent idiopathic scoliosis undergoing a posterior spinal fusion and segmental spinal instrumentation and who had a bipolar sealer device used during their surgery was compared with a control group of the 50 preceding consecutive patients who did not. Anesthesia, surgical technique, use of intraoperative epsilon aminocaproic acid (Amicar), postoperative protocol, and indications for transfusions (hemoglobin≤7.0 g/dL) were identical in both groups. The preoperative demographics for the patients in both groups were statistically the same. The bipolar sealer group demonstrated a significant reduction in intraoperative estimated blood loss, total perioperative blood loss, volume of blood products transfused, and overall transfusion rate when compared with the control group. When subgroups consisting of only hybrid or all-pedicle screw constructs were considered individually, these findings remained consistent. There were no complications associated with the use of this device. Using the bipolar sealer device is a significant adjunct in decreasing perioperative blood loss and transfusion requirements in patients undergoing surgery for adolescent idiopathic scoliosis. Level III-retrospective comparative study.

  14. Utilization technique on variable speed device

    International Nuclear Information System (INIS)

    1989-12-01

    This reports of workshop on power technology describes using technique on variable speed device, which deals with alternating current situation and prospect of current variable speed device, technical trend and prospect of electronics, reduce expenses by variable speed device, control technique, measurement technology, high voltage variable speed device, recent trend of inverter technology, low voltage and high voltage variable speed device control device, operating variable speed device in cooling fan, FDF application and defect case of variable speed device, cooling pump application of water variable transformer, inverter application and energy effect of ventilation equipment, application of variable speed device and analysis of the result of operation and study for application of variable speed technology.

  15. High-level Programming and Symbolic Reasoning on IoT Resource Constrained Devices

    Directory of Open Access Journals (Sweden)

    Sal vatore Gaglio

    2015-05-01

    Full Text Available While the vision of Internet of Things (IoT is rather inspiring, its practical implementation remains challenging. Conventional programming approaches prove unsuitable to provide IoT resource constrained devices with the distributed processing capabilities required to implement intelligent, autonomic, and self-organizing behaviors. In our previous work, we had already proposed an alternative programming methodology for such systems that is characterized by high-level programming and symbolic expressions evaluation, and developed a lightweight middleware to support it. Our approach allows for interactive programming of deployed nodes, and it is based on the simple but e ective paradigm of executable code exchange among nodes. In this paper, we show how our methodology can be used to provide IoT resource constrained devices with reasoning abilities by implementing a Fuzzy Logic symbolic extension on deployed nodes at runtime.

  16. Development of High-Temperature, High-Power, High-Efficiency, High-Voltage Converters Using Silicon Carbide (SiC) Delivery Order 0003: SiC High Voltage Converters, N-Type Ohmic Contract Development for SiC Power Devices

    National Research Council Canada - National Science Library

    Cheng, Lin; Mazzola, Michael S

    2006-01-01

    ... ? SiC interfaces and silicide top surfaces is important for producing uniformly low contact resistances to achieve device operation at high-current levels without hot spot formation and contact degradation...

  17. Prevention of hypothermia in patients undergoing orthotopic liver transplantation using the humigard® open surgery humidification system: a prospective randomized pilot and feasibility clinical trial.

    Science.gov (United States)

    Weinberg, Laurence; Huang, Andrew; Alban, Daniel; Jones, Robert; Story, David; McNicol, Larry; Pearce, Brett

    2017-01-23

    Perioperative thermal disturbances during orthotopic liver transplantation (OLT) are common. We hypothesized that in patients undergoing OLT the use of a humidified high flow CO 2 warming system maintains higher intraoperative temperatures when compared to standardized multimodal strategies to maintain thermoregulatory homeostasis. We performed a randomized pilot study in adult patients undergoing primary OLT. Participants were randomized to receive either open wound humidification with a high flow CO 2 warming system in addition to standard care (Humidification group) or to standard care alone (Control group). The primary end point was nasopharyngeal core temperature measured 5 min immediately prior to reperfusion of the donor liver (Stage 3 - 5 min). Secondary endpoints included intraoperative PaCO 2 , minute ventilation and the use of vasoconstrictors. Eleven patients were randomized to each group. Both groups were similar for age, body mass index, MELD, SOFA and APACHE II scores, baseline temperature, and duration of surgery. Immediately prior to reperfusion (Stage 3 - 5 min) the mean (SD) core temperature was higher in the Humidification Group compared to the Control Group: 36.0 °C (0.13) vs. 35.4 °C (0.22), p = 0.028. Repeated measured ANOVA showed that core temperatures over time during the stages of the transplant were higher in the Humidification Group compared to the Control Group (p < 0.0001). There were no significant differences in the ETCO 2 , PaCO 2 , minute ventilation, or inotropic support. The humidified high flow CO 2 warming system was superior to standardized multimodal strategies in maintaining normothermia in patients undergoing OLT. Use of the device was feasible and did not interfere with any aspects of surgery. A larger study is needed to investigate if the improved thermoregulation observed is associated with improved patient outcomes. ACTRN12616001631493 . Retrospectively registered 25 November 2016.

  18. High-performance alternating current field-induced chromatic-stable white polymer electroluminescent devices employing a down-conversion layer

    Energy Technology Data Exchange (ETDEWEB)

    Xia, Yingdong; Chen, Yonghua; Smith, Gregory M. [Center for Nanotechnology and Molecular Materials, Department of Physics, Wake Forest University, Winston-Salem, NC 27105 (United States); Sun, Hengda; Yang, Dezhi [State Key Laboratory of Polymer Physics and Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun 130022 (China); Nie, Wanyi; Li, Yuan; Huang, Wenxiao [Center for Nanotechnology and Molecular Materials, Department of Physics, Wake Forest University, Winston-Salem, NC 27105 (United States); Ma, Dongge [State Key Laboratory of Polymer Physics and Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun 130022 (China); Carroll, David L., E-mail: carroldl@wfu.edu [Center for Nanotechnology and Molecular Materials, Department of Physics, Wake Forest University, Winston-Salem, NC 27105 (United States)

    2015-05-15

    In this work, a high-performance alternating current (AC) filed-induced chromatic-stable white polymer electroluminescence (WFIPEL) device was fabricated by combining a fluorophor Poly(9,9-dioctylfluorene) (PFO)-based blue device with a yellow down-conversion layer (YAG:Ce). A maximum luminance of this down-conversion FIPEL device achieves 3230 cd m{sup −2}, which is 1.41 times higher than the device without the down-conversion layer. A maximum current efficiency and power efficiency of the down-conversion WFIPEL device reach 19.7 cd A{sup −1} at 3050 cd m{sup −2} and 5.37 lm W{sup −1} at 2310 cd m{sup −2} respectively. To the best of our knowledge, the power efficiency is one of the highest reports for the WFIPEL up to now. Moreover, Commison Internationale de L’Eclairage (CIE) coordinates of (0.28, 0.30) is obtained by adjusting the thickness of the down-conversion layer to 30 μm and it is kept stable over the entire AC-driven voltage range. We believe that this AC-driven, down-conversion, WFIPEL device may offer an easy way towards future flat and flexible lighting sources. - Highlights: • A high-performance AC filed-induced chromatic-stable white polymer electroluminescence (WFIPEL) device was fabricated. • A maximum luminance, current efficiency, and power efficiency achieves 3230 cd m{sup −2}, 19.7 cd A{sup −1}, and 5.37 lm W{sup −1}, respectively. • The power efficiency is one of the highest reports for the WFIPEL up to now. • The EL spectrum kept very stable over the entire AC-driven voltage range.

  19. Transfer-less flexible and transparent high-κ/metal gate germanium devices on bulk silicon (100)

    KAUST Repository

    Nassar, Joanna M.; Hussain, Aftab M.; Rojas, Jhonathan Prieto; Hussain, Muhammad Mustafa

    2014-01-01

    Flexible wearable electronics have been of great interest lately for the development of innovative future technology for various interactive applications in the field of consumer electronics and advanced healthcare, offering the promise of low-cost, lightweight, and multifunctionality. In the pursuit of this trend, high mobility channel materials need to be investigated on a flexible platform, for the development of flexible high performance devices. Germanium (Ge) is one of the most attractive alternatives for silicon (Si) for high-speed computational applications, due its higher hole and electron mobility. Thus, in this work we show a cost effective CMOS compatible process for transforming conventional rigid Ge metal oxide semiconductor capacitors (MOSCAPS) into a mechanically flexible and semi-transparent platform. Devices exhibit outstanding bendability with a bending radius of 0.24 cm, and semi-transparency up to 30 %, varying with respect to the diameter size of the release holes array.

  20. Transfer-less flexible and transparent high-κ/metal gate germanium devices on bulk silicon (100)

    KAUST Repository

    Nassar, Joanna M.

    2014-08-01

    Flexible wearable electronics have been of great interest lately for the development of innovative future technology for various interactive applications in the field of consumer electronics and advanced healthcare, offering the promise of low-cost, lightweight, and multifunctionality. In the pursuit of this trend, high mobility channel materials need to be investigated on a flexible platform, for the development of flexible high performance devices. Germanium (Ge) is one of the most attractive alternatives for silicon (Si) for high-speed computational applications, due its higher hole and electron mobility. Thus, in this work we show a cost effective CMOS compatible process for transforming conventional rigid Ge metal oxide semiconductor capacitors (MOSCAPS) into a mechanically flexible and semi-transparent platform. Devices exhibit outstanding bendability with a bending radius of 0.24 cm, and semi-transparency up to 30 %, varying with respect to the diameter size of the release holes array.

  1. High Temperature Electro-Mechanical Devices For Nuclear Applications

    International Nuclear Information System (INIS)

    Robertson, D.

    2010-01-01

    Nuclear power plants require a number of electro-mechanical devices, for example, Control Rod Drive Mechanisms (CRDM's) to control the raising and lowering of control rods and Reactor Coolant Pumps (RCP's) to circulate the primary coolant. There are potential benefits in locating electro-mechanical components in areas of the plant with high ambient temperatures. One such benefit is the reduced need to make penetrations in pressure vessels leading to simplified plant design and improved inherent safety. The feature that limits the ambient temperature at which most electrical machines may operate is the material used for the electrical insulation of the machine windings. Conventional electrical machines generally use polymer-based insulation that limits the ambient temperature they can operate in to below 200 degrees Celsius. This means that when a conventional electrical machine is required to operate in a hot area it must be actively cooled necessitating additional systems. This paper presents data gathered during investigations undertaken by Rolls-Royce into the design of high temperature electrical machines. The research was undertaken at Rolls-Royce's University Technology Centre in Advanced Electrical Machines and Drives at Sheffield University. Rolls- Royce has also been investigating high temperature wire and encapsulants and latterly techniques to provide high temperature insulation to terminations. Rolls-Royce used the experience gained from these tests to produce a high temperature electrical linear actuator at sizes representative of those used in reactor systems. This machine was tested successfully at temperatures equivalent to those found inside the reactor vessel of a pressurised water reactor through a full series of operations that replicated in service duty. The paper will conclude by discussing the impact of the findings and potential electro-mechanical designs that may utilise such high temperature technologies. (authors)

  2. High and tunable spin current induced by magnetic-electric fields in a single-mode spintronic device

    International Nuclear Information System (INIS)

    Bala Kumar, S; Jalil, M B A; Tan, S G; Liang, G-C

    2009-01-01

    We proposed that a viable form of spin current transistor is one to be made from a single-mode device which passes electrons through a series of magnetic-electric barriers built into the device. The barriers assume a wavy spatial profile across the conduction path due to the inevitable broadening of the magnetic fields. Field broadening results in a linearly increasing vector potential across the conduction channel, which increases spin polarization. We have identified that the important factors for generating high spin polarization and conductance modulation are the low source-drain bias, the broadened magnetic fields, and the high number of FM gates within a fixed channel length.

  3. High-speed automated NDT device for niobium plate using scanning laser acoustic microscopy

    International Nuclear Information System (INIS)

    Oravecz, M.G.; Yu, B.Y.; Riney, K.; Kessler, L.W.; Padamsee, H.

    1988-01-01

    This paper presents a nondestructive testing (NDT) device which rapidly and automatically identifies defects throughout the volume of a 23.4 cm x 23.4 cm x 0.3 cm, pure niobium plate using Scanning Laser Acoustic Microscope (SLAM), high-resolution, 60 MHz, ultrasonic images. A principle advantage of the SLAM technique is that it combines a video scan rate with a high scan density (130 lines/mm at 60 MHz). To automate the inspection system they integrated under computer control the following: the SLAM RS-170/330 video output, a computerized XY plate scanner, a real-time video digitizer/integrator, a computer algorithm for defect detection, a digital mass storage device, and a hardcopy output device. The key element was development of an efficient, reliable defect detection algorithm using a variance filter with a locally determined threshold. This algorithm is responsible for recognizing valid flaws in the midst of random texture. This texture was seen throughout the acoustic images and was caused by the niobium microstructure. The images, as analyzed, contained 128 x 120 pixels with 64 grey levels per pixel. This system allows economical inspection of the large quantities (eg. 100 tons) of material needed for future particle accelerators based on microwave superconductivity. Rapid nondestructive inspection of pure niobium sheet is required because current accelerator performance is largely limited by the quality of commercially available material. Previous work documented critical flaws that are detectable by SLAM techniques. 15 references, 9 figures

  4. High Tc superconducting three-terminal device under quasi-particle injection

    International Nuclear Information System (INIS)

    Hashimoto, K.; Kabasawa, U.; Tonouchi, M.; Kobayashi, T.

    1988-01-01

    A new type of the current injection type three terminal device was fabricated using the high Tc YBaCuO thin epitaxial films, wherein the hot quasi-particle injection effect on the superconducting current was closely examined. The zero bias drain current was efficiently suppressed by the injection of the hot quasi-particles through the gate electrode. Though it is speculative, a comparison of the experimental results and analyses based on the familiar BCS theory intimates that the main mechanism of the current modulation is the non-equilibrium superconductivity due to accumulation of the excess quasi-particles

  5. Fabrication of high crystalline SnS and SnS2 thin films, and their switching device characteristics

    Science.gov (United States)

    Choi, Hyeongsu; Lee, Jeongsu; Shin, Seokyoon; Lee, Juhyun; Lee, Seungjin; Park, Hyunwoo; Kwon, Sejin; Lee, Namgue; Bang, Minwook; Lee, Seung-Beck; Jeon, Hyeongtag

    2018-05-01

    Representative tin sulfide compounds, tin monosulfide (SnS) and tin disulfide (SnS2) are strong candidates for future nanoelectronic devices, based on non-toxicity, low cost, unique structures and optoelectronic properties. However, it is insufficient for synthesizing of tin sulfide thin films using vapor phase deposition method which is capable of fabricating reproducible device and securing high quality films, and their device characteristics. In this study, we obtained highly crystalline SnS thin films by atomic layer deposition and obtained highly crystalline SnS2 thin films by phase transition of the SnS thin films. The SnS thin film was transformed into SnS2 thin film by annealing at 450 °C for 1 h in H2S atmosphere. This phase transition was confirmed by x-ray diffractometer and x-ray photoelectron spectroscopy, and we studied the cause of the phase transition. We then compared the film characteristics of these two tin sulfide thin films and their switching device characteristics. SnS and SnS2 thin films had optical bandgaps of 1.35 and 2.70 eV, and absorption coefficients of about 105 and 104 cm‑1 in the visible region, respectively. In addition, SnS and SnS2 thin films exhibited p-type and n-type semiconductor characteristics. In the images of high resolution-transmission electron microscopy, SnS and SnS2 directly showed a highly crystalline orthorhombic and hexagonal layered structure. The field effect transistors of SnS and SnS2 thin films exhibited on–off drain current ratios of 8.8 and 2.1 × 103 and mobilities of 0.21 and 0.014 cm2 V‑1 s‑1, respectively. This difference in switching device characteristics mainly depends on the carrier concentration because it contributes to off-state conductance and mobility. The major carrier concentrations of the SnS and SnS2 thin films were 6.0 × 1016 and 8.7 × 1013 cm‑3, respectively, in this experiment.

  6. Cellular Profile and Expression of Immunologic Markers in Chronic Apical Periodontitis from HIV-infected Patients Undergoing Highly Active Antiretroviral Therapy.

    Science.gov (United States)

    Gama, Túlio Gustavo Veiga; Pires, Fabio Ramoa; Armada, Luciana; Gonçalves, Lucio Souza

    2016-06-01

    This study tested the hypothesis that the inflammatory cell profile (CD3-, CD4-, CD8-, CD20-, and CD68-positive cells) and the expression of immunologic markers (tumor necrosis factor α, interferon-γ, interleukin-6, and interleukin-18) in chronic apical periodontitis are the same between non-HIV-infected patients and HIV-infected patients undergoing highly active antiretroviral therapy (HAART). Thirty-four surgically excised chronic apical periodontitis lesions were sampled from 34 patients (17 HIV-infected and 17 non-HIV-infected). The lesions were extracted from teeth with no previous endodontic treatment. All HIV-infected patients were undergoing HAART. The specimens were submitted to histopathologic and immunohistochemical analyses by using an optical microscope. Immunoexpression was graded into 2 levels, focal to weak and moderate to strong. The χ(2), Fisher exact, and Mann-Whitney tests were used to analyze all significant differences between groups. Periapical cysts represented 70.6% and 52.9% of the lesions in the HIV-infected and non-HIV-infected groups, respectively; however, no statistically significant difference was observed (P = .481). There were no statistically significant differences between groups for the inflammatory cell profile and for any of the immunologic markers (P > .05). There are no statistically significant differences of the cellular profile and expression of immunologic markers in chronic apical periodontitis between non-HIV-infected patients and HIV-infected patients undergoing HAART. Copyright © 2016 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  7. Semiconductor devices as track detectors in high energy colliding beam experiments

    International Nuclear Information System (INIS)

    Ludlam, T.

    1980-01-01

    In considering the design of experiments for high energy colliding beam facilities one quickly sees the need for better detectors. The full exploitation of machines like ISABELLE will call for detector capabilities beyond what can be expected from refinements of the conventional approaches to particle detection in high energy physics experiments. Over the past year or so there has been a general realization that semiconductor device technology offers the possibility of position sensing detectors having resolution elements with dimensions of the order of 10 microns or smaller. Such a detector could offer enormous advantages in the design of experiments, and the purpose of this paper is to discuss some of the possibilities and some of the problems

  8. Semiconductor devices as track detectors in high energy colliding beam experiments

    Energy Technology Data Exchange (ETDEWEB)

    Ludlam, T

    1980-01-01

    In considering the design of experiments for high energy colliding beam facilities one quickly sees the need for better detectors. The full exploitation of machines like ISABELLE will call for detector capabilities beyond what can be expected from refinements of the conventional approaches to particle detection in high energy physics experiments. Over the past year or so there has been a general realization that semiconductor device technology offers the possibility of position sensing detectors having resolution elements with dimensions of the order of 10 microns or smaller. Such a detector could offer enormous advantages in the design of experiments, and the purpose of this paper is to discuss some of the possibilities and some of the problems.

  9. Low Defect Density Substrates and High-Quality Epi-Substrate Interfaces for ABCS Devices and Progress Toward Phonon-Mediated THz Lasers

    National Research Council Canada - National Science Library

    Goodhue, William; Bliss, David; Krishnaswami, Kannan; Vangala, Shivashankar; Li, Jin; Zhu, Beihong

    2005-01-01

    ... has been developing technology for producing low defect density substrates and high-quality epi-substrate interfaces for ABCS device applications as well as developing fabrication and device concepts...

  10. FY 2000 report on the trend survey of technical development of high speed/high function electronic devices such as quantum functional devices in association with the rationalization of energy utilization; 2000 nendo energy shiyo gorika ni kakawaru ryoshika kino soshi nado kosoku kokino denshi device no gijutsu kaihatsu doko chosa hokokusho

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-03-01

    Concerning the results of the R and D made by NEDO of superlattice devices (FY 1981-1990) and quantum functional devices (QFD) (FY 1991-2000) as high speed/high function electronic devices, this survey was aimed at investigating the trend of the newest technology to grasp the technical effects, the state of commercialization/product-making, and the future. The effects, technical subjects, etc. in the R and D of superlattice devices were succeeded to the R and D of QFD as the succeeding project. Here, therefore, the paper arranged the outlook of the commercialization/product-making in relation to the R and D of QFD and the future R and D subjects. In the R and D, features of QFD as target were made clear. The commercialization is limited to Motorola's QMMIC, Fujitsu's RHET, etc. As to the other R and D items, subjects of the technical development to be implemented toward the commercialization just became clear. The subject is the heightening of micro (nano meter) processing technology. The important subject, in particular, is compatibility of the heightening of micro processing and the improvement of throughput. (NEDO)

  11. Three-terminal superconducting devices

    International Nuclear Information System (INIS)

    Gallagher, W.J.

    1985-01-01

    The transistor has a number of properties that make it so useful. The authors discuss these and the additional properties a transistor would need to have for high performance applications at temperatures where superconductivity could contribute advantages to system-level performance. These properties then serve as criteria by which to evaluate three-terminal devices that have been proposed for applications at superconducting temperatures. FETs can retain their transistor properties at low temperatures, but their power consumption is too large for high-speed, high-density cryogenic applications. They discuss in detail why demonstrated superconducting devices with three terminals -Josephson effect based devices, injection controlled weak links, and stacked tunnel junction devices such as the superconducting transistor proposed by K. Gray and the quiteron -- each fail to have true transistor-like properties. They conclude that the potentially very rewarding search for a transistor compatible with superconductivity in high performance applications must be in new directions

  12. The effect of tourniquet deflation on hemodynamics and regional cerebral oxygen saturation in aged patients undergoing total knee replacement surgery

    OpenAIRE

    Song, Inkyung; Kim, Dong Yeon; Kim, Youn Jin

    2012-01-01

    Background Inflation and deflation of a pneumatic tourniquet used in total knee replacement surgery induces various changes in patient's hemodynamic and metabolic status, which may result in serious complications, especially in aged patients. Near-infrared spectroscopy (NIRS) is a monitoring device designed to estimate the regional cerebral oxygen saturation. We evaluated the effect of tourniquet deflation on hemodynamics and regional cerebral oxygen saturation in aged patients undergoing tot...

  13. Improving distillation method and device of tritiated water analysis for ultra high decontamination efficiency

    International Nuclear Information System (INIS)

    Fang, Hsin-Fa; Wang, Chu-Fang; Lin, Chien-Kung

    2015-01-01

    It is important that monitoring environmental tritiated water for understanding the contamination dispersion of the nuclear facilities. Tritium is a pure beta radionuclide which is usually measured by Liquid Scintillation Counting (LSC). The average energy of tritum beta is only 5.658 keV that makes the LSC counting of tritium easily be interfered by the beta emitted by other radionuclides. Environmental tritiated water samples usually need to be decontaminated by distillation for reducing the interference. After Fukushima Nucleaer Accident, the highest gross beta concentration of groundwater samples obtained around Fukushima Daiichi Nuclear Power Station is over 1,000,000 Bq/l. There is a need for a distillation with ultra-high decontamination efficiency for environmental tritiated water analysis. This study is intended to improve the heating temperature control for better sub-boiling distillation control and modify the height of the container of the air cooling distillation device for better fractional distillation effect. The DF of Cs-137 of the distillation may reach 450,000 which is far better than the prior study. The average loss rate of the improved method and device is about 2.6% which is better than the bias value listed in the ASTM D4107-08. It is proven that the modified air cooling distillation device can provide an easy-handling, water-saving, low cost and effective way of purifying water samples for higher beta radionuclides contaminated water samples which need ultra-high decontamination treatment. - Highlights: • The improvements of method and device make the decontaminatin factor (DF) of Cs-137 of distillation reach over 450,000. • The decontamination factor ( DF) value may be increased about 20 times by increasing the height of the container from 7 cm to 20 cm. • The device provides an easy-handling, water-saving, low cost, stable and effective way for the distillation of triated water analysis.

  14. Optimal Operation and Dispatch of Voltage Regulation Devices Considering High Penetrations of Distributed Photovoltaic Generation

    Energy Technology Data Exchange (ETDEWEB)

    Mather, Barry A [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Hodge, Brian S [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Cho, Gyu-Jung [Sungkyunkwan University; Oh, Yun-Sik [Sungkyunkwan University; Kim, Min-Sung [Sungkyunkwan University; Kim, Ji-Soo [Sungkyunkwan University; Kim, Chul-Hwan [Sungkyunkwan University

    2017-06-29

    Voltage regulation devices have been traditionally installed and utilized to support distribution voltages. Installations of distributed energy resources (DERs) in distribution systems are rapidly increasing, and many of these generation resources have variable and uncertain power output. These generators can significantly change the voltage profile for a feeder; therefore, in the distribution system planning stage of the optimal operation and dispatch of voltage regulation devices, possible high penetrations of DERs should be considered. In this paper, we model the IEEE 34-bus test feeder, including all essential equipment. An optimization method is adopted to determine the optimal siting and operation of the voltage regulation devices in the presence of distributed solar power generation. Finally, we verify the optimal configuration of the entire system through the optimization and simulation results.

  15. Recent progress in power electronic devices

    Energy Technology Data Exchange (ETDEWEB)

    Ikeda, Yasuhiko; Yatsuo, Tsutomu

    1987-02-01

    Recent progress and future trends of power semiconductor devices (especially with respect to motor speed control) were described. Conventional discrete devices such as thyristors, bipolar transistors, unipolar transistors and Bi-MOS devices were referenced to. Reference was also made to High Voltage ICs. There has been steady progress with each of these power devices in current carrying capability, voltage blocking capability and switching speed. The Bipolar-MOS integreated device and the High Voltage IC are particularly interesting because their abilities and performances are much enhanced by skillful combination with conventional discrete devices. However, no one device meets all the needs, and it will always be necessary to select the right device for a specific task. (11 figs, 35 refs)

  16. High performance yellow organic electroluminescent devices by doping iridium(III) complex into host materials with stepwise energy levels

    Energy Technology Data Exchange (ETDEWEB)

    Cui, Rongzhen; Zhou, Liang, E-mail: zhoul@ciac.ac.cn; Jiang, Yunlong; Li, Yanan; Zhao, Xuesen; Zhang, Hongjie, E-mail: hongjie@ciac.ac.cn

    2015-10-15

    In this work, we aim to further improve the electroluminescent (EL) performances of a yellow light-emitting iridium(III) complex by designing double light-emitting layers (EMLs) devices having stepwise energy levels. Compared with single-EML devices, these designed double-EML devices showed improved EL efficiency and brightness attributed to better balance in carriers. In addition, the stepwise distribution in energy levels of host materials is instrumental in broadening the recombination zone, thus delaying the roll-off of EL efficiency. Based on the investigation of carriers' distribution, device structure was further optimized by adjusting the thickness of deposited layers. Finally, yellow EL device (Commission Internationale de l'Eclairage (CIE) coordinates of (0.446, 0.542)) with maximum current efficiency, power efficiency and brightness up to 78.62 cd/A (external quantum efficiency (EQE) of 21.1%), 82.28 lm/W and 72,713 cd/m{sup 2}, respectively, was obtained. Even at the high brightness of 1000 cd/m{sup 2}, EL efficiency as high as 65.54 cd/A (EQE=17.6%) can be retained. - Highlights: • Yellow electroluminescent devices were designed and fabricated. • P-type and n-type materials having stepwise energy levels were chosen as host materials. • Better balance of holes and electrons causes the enhanced efficiencies. • Improved carriers' trapping suppresses the emission of host material.

  17. Direct patterning of highly-conductive graphene@copper composites using copper naphthenate as a resist for graphene device applications.

    Science.gov (United States)

    Bi, Kaixi; Xiang, Quan; Chen, Yiqin; Shi, Huimin; Li, Zhiqin; Lin, Jun; Zhang, Yongzhe; Wan, Qiang; Zhang, Guanhua; Qin, Shiqiao; Zhang, Xueao; Duan, Huigao

    2017-11-09

    We report an electron-beam lithography process to directly fabricate graphene@copper composite patterns without involving metal deposition, lift-off and etching processes using copper naphthenate as a high-resolution negative-tone resist. As a commonly used industrial painting product, copper naphthenate is extremely cheap with a long shelf time but demonstrates an unexpected patterning resolution better than 10 nm. With appropriate annealing under a hydrogen atmosphere, the produced graphene@copper composite patterns show high conductivity of ∼400 S cm -1 . X-ray diffraction, conformal Raman spectroscopy and X-ray photoelectron spectroscopy were used to analyze the chemical composition of the final patterns. With the properties of high resolution and high conductivity, the patterned graphene@copper composites could be used as conductive pads and interconnects for graphene electronic devices with ohmic contacts. Compared to common fabrication processes involving metal evaporation and lift-off steps, this pattern-transfer-free fabrication process using copper naphthenate resist is direct and simple but allows comparable device performance in practical device applications.

  18. Clinical Assessment of Intraventricular Blood Transport in Patients Undergoing Cardiac Resynchronization Therapy

    Science.gov (United States)

    Rossini, Lorenzo; Martinez-Legazpi, P.; Benito, Y.; Perez Del Villar, C.; Gonzalez-Mansilla, A.; Barrio, A.; Yotti, R.; Kahn, A. M.; Shadden, S. C.; Fernandez-Aviles, F.; Bermejo, J.; Del Alamo, J. C.

    2015-11-01

    In the healthy heart, left ventricular (LV) filling generates flow patterns which have been proposed to optimize blood transport by coupling diastole and systole phases. We present a novel image-based method to assess how flow patterns influence LV blood transport in patients undergoing cardiac resynchronization therapy (CRT). Solving the advection equation with time-varying inflow boundary conditions allows to track the transport of blood entering the LV in the different filling waves, as well as the transport barriers which couple filling and ejection. The velocity fields were obtained using echocardiographic color Doppler velocimetry, which provides two-dimensional time-resolved flow maps in the apical long axis three-chamber view of the LV. We analyze flow transport in a group of patients with CRT devices as well as in healthy volunteers. In the patients under CRT, the device programming was varied to analyze flow transport under different values of the atrioventricular (AV) conduction delay and to model tachycardia. This analysis illustrates how CRT influences the transit of blood inside the LV, contributes to conserving kinetic energy and favors the generation of hemodynamic forces that accelerate blood in the direction of the LV outflow tract.

  19. High-power waveguide resonator second harmonic device with external conversion efficiency up to 75%

    Science.gov (United States)

    Stefszky, M.; Ricken, R.; Eigner, C.; Quiring, V.; Herrmann, H.; Silberhorn, C.

    2018-06-01

    We report on a highly efficient waveguide resonator device for the production of 775 nm light using a titanium indiffused LiNbO3 waveguide resonator. When scanning the resonance, the device produces up to 110 mW of second harmonic power with 140 mW incident on the device—an external conversion efficiency of 75%. The cavity length is also locked, using a Pound–Drever–Hall type locking scheme, involving feedback to either the cavity temperature or the laser frequency. With laser frequency feedback, a stable output power of approximately 28 mW from a 52 mW pump is seen over one hour.

  20. High-frequency profile in adolescents and its relationship with the use of personal stereo devices.

    Science.gov (United States)

    Silvestre, Renata Almeida Araújo; Ribas, Ângela; Hammerschmidt, Rogério; de Lacerda, Adriana Bender Moreira

    2016-01-01

    To analyze and correlate the audiometric findings of high frequencies (9-16 kHz) in adolescents with their hearing habits and attitudes, in order to prevent noise-induced hearing loss. This was a descriptive cross-sectional study, which included 125 adolescents in a sample of normal-hearing students, at a state school. The subjects performed high-frequency audiometry testing and answered a self-administered questionnaire addressing information on sound habits concerning the use of personal stereo devices. The sample was divided according to the exposure characteristics (time, duration, intensity, etc.) and the results were compared with the observed thresholds, through the difference in proportions test, chi-squared, Student's t-test, and ANOVA, all at a significance level of 0.05. Average high-frequency thresholds were registered below 15 dB HL and no significant correlation was found between high frequency audiometric findings and the degree of exposure. The prevalence of harmful sound habits due to the use of personal stereo devices is high in the adolescent population, but there was no correlation between exposure to high sound pressure levels through personal stereos and the high-frequency thresholds in this population. Copyright © 2016 Sociedade Brasileira de Pediatria. Published by Elsevier Editora Ltda. All rights reserved.

  1. Proceedings of US/Japan workshop, Q219 on high heat flux components and plasma surface interactions for next fusion devices

    Energy Technology Data Exchange (ETDEWEB)

    Ulrickson, M.A.; Stevens, P.L.; Hino, T.; Hirohata, Y. [eds.

    1996-12-01

    This report contains the viewgraphs from the proceedings of US/Japan Workshop on High Heat Flux Components and Plasma Surface Interactions for Next Fusion Devices. Some of the general topics covered by this report are: PFC/PSI in tokamak and helical devices; development of high heat flux components; PSIS and plasma facing materials;tritium; and material damage.

  2. Proceedings of US/Japan workshop, Q219 on high heat flux components and plasma surface interactions for next fusion devices

    International Nuclear Information System (INIS)

    Ulrickson, M.A.; Stevens, P.L.; Hino, T.; Hirohata, Y.

    1996-12-01

    This report contains the viewgraphs from the proceedings of US/Japan Workshop on High Heat Flux Components and Plasma Surface Interactions for Next Fusion Devices. Some of the general topics covered by this report are: PFC/PSI in tokamak and helical devices; development of high heat flux components; PSIS and plasma facing materials;tritium; and material damage

  3. Design Procedure and Fabrication of Reproducible Silicon Vernier Devices for High-Performance Refractive Index Sensing.

    Science.gov (United States)

    Troia, Benedetto; Khokhar, Ali Z; Nedeljkovic, Milos; Reynolds, Scott A; Hu, Youfang; Mashanovich, Goran Z; Passaro, Vittorio M N

    2015-06-10

    In this paper, we propose a generalized procedure for the design of integrated Vernier devices for high performance chemical and biochemical sensing. In particular, we demonstrate the accurate control of the most critical design and fabrication parameters of silicon-on-insulator cascade-coupled racetrack resonators operating in the second regime of the Vernier effect, around 1.55 μm. The experimental implementation of our design strategies has allowed a rigorous and reliable investigation of the influence of racetrack resonator and directional coupler dimensions as well as of waveguide process variability on the operation of Vernier devices. Figures of merit of our Vernier architectures have been measured experimentally, evidencing a high reproducibility and a very good agreement with the theoretical predictions, as also confirmed by relative errors even lower than 1%. Finally, a Vernier gain as high as 30.3, average insertion loss of 2.1 dB and extinction ratio up to 30 dB have been achieved.

  4. Use of intelligent devices in high-energy physics experiments

    International Nuclear Information System (INIS)

    Verkerk, C.

    1981-01-01

    In these lectures we concentrate on two areas for which special devices have been developed: On line data processing, generally to perform event selection and/or to achieve compaction of data before recording. Preparation of experimental apparatus: testing of detectors, optimimization of operating conditions and calibration. Much attention will be given to the event-selection process and the devices used for this purpose. (orig./HSI)

  5. Research Area 4.1 Nano- and Bio-Electronics: Lester Eastman Conference on High-Performance Devices

    Science.gov (United States)

    2017-06-02

    significantly lower. Moreover, wells containing MoS2 on the polyimide film had a large amount of cells growing on the material, further indicating high ...SECURITY CLASSIFICATION OF: 1. REPORT DATE (DD-MM-YYYY) 4. TITLE AND SUBTITLE 13. SUPPLEMENTARY NOTES 12. DISTRIBUTION AVAILIBILITY STATEMENT 6...Research Area 4.1 Nano- and Bio-Electronics: Lester Eastman Conference on High -Performance Devices The 2016 IEEE Lester Eastman Conference of High

  6. Graphene-based vdW heterostructure Induced High-efficiency Thermoelectric Devices

    Science.gov (United States)

    Liang, Shijun; Ang, Lay Kee

    Thermoelectric material (TE) can convert the heat into electricity to provide green energy source and its performance is characterized by a figure of merit (ZT) parameter. Traditional TE materials only give ZT equal to around 1 at room temperature. But, it is believed that materials with ZT >3 will find wide applications at this low temperature range. Prior studies have implied that the interrelation between electric conductivity and lattice thermal conductivity renders the goal of engineering ZT of bulk materials to reach ZT >3. In this work, we propose a high-efficiency van del Waals (vdW) heterostructure-based thermionic device with graphene electrodes, which is able to harvest wasted heat (around 400K) based on the newly established thermionic emission law of graphene electrodes instead of Seebeck effect, to boost the efficiency of power generation over 10% around room temperature. The efficiency can be above 20% if the Schottky barrier height and cross-plane lattice thermal conductivity of transition metal dichacogenides (TMD) materials can be fine-engineered. As a refrigerator at 260 K, the efficiency is 50% to 80% of Carnot efficiency. Finally, we identify two TMD materials as the ideal candidates of graphene/TMD/graphene devices based on the state-of-art technology.

  7. Cooling device in thermonuclear device

    International Nuclear Information System (INIS)

    Honda, Tsutomu.

    1988-01-01

    Purpose: To prevent loss of cooling effect over the entire torus structure directly after accidental toubles in a cooling device of a thermonuclear device. Constitution: Coolant recycling means of a cooling device comprises two systems, which are alternately connected with in-flow pipeways and exit pipeways of adjacent modules. The modules are cooled by way of the in-flow pipeways and the exist pipeways connected to the respective modules by means of the coolant recycling means corresponding to the respective modules. So long as one of the coolant recycling means is kept operative, since every one other modules of the torus structure is still kept cooled, the heat generated from the module put therebetween, for which the coolant recycling is interrupted, is removed by means of heat conduction or radiation from the module for which the cooling is kept continued. No back-up emergency cooling system is required and it can provide high economic reliability. (Kamimura, M.)

  8. Contrast nephropathy in high-risk patients undergoing coronary angiography and intervention

    International Nuclear Information System (INIS)

    Uddin, M.A.; Rabbani, M.A.; Jafary, F.H.; Bhatti, M.A.; Islam, M.

    2005-01-01

    Objective: To determine the incidence of contrast nephropathy in high-risk patients undergoing coronary angiography and percutaneous coronary intervention (PCI), and to define the characteristics of this cohort. Design: Descriptive study. Place and Duration of Study: The Aga Khan University Hospital, Karachi from January to December 2002. Patients and Methods: One hundred and fifteen patients with serum creatinine greater than 1.4mg/dl who underwent coronary angiography or PCI were included. All patients received non-ionic contrast dye. Acute contrast nephropathy was defined as rise in serum creatinine of >0.5mg/dl within 48 hours following the index procedure. Means and standard deviations were calculated for continuous variables and frequencies for categorical variables. Results: Mean age of patients was 62.3 year + 8.83. Mean pre-contrast creatinine was 1.9+0.9mg/dl. Eleven (9.65%) patients developed contrast nephropathy. 4.4% of patients with serum creatinine 4.0(p-value 0.001). 11.9% diabetic patients developed nephropathy compared to 6.3% of non-diabetics (p-value 0.355). 11.4% of hypertensive and 3.7% of non-hypertensive patients developed contrast-nephropathy (p-value 0.454). 12.9% of low dose group ( 100ml) developed nephropathy (p-value 0.188). Mean serum creatinine in low dose group was higher (3.0mg/dl vs. 1.7 mg/dl). Conclusion: The incidence of contrast nephropathy in this study was similar to that reported in literature. Risk of CIN was found to be significantly proportional to the severity of baseline renal disease. Trends towards higher risk of CIN were seen in patients with diabetes and hypertension. Higher incidence of CIN in patients receiving low-dose contrast was confounded by higher baseline serum creatinine in that group. (author)

  9. Highly flexible peeled-off silver nanowire transparent anode using in organic light-emitting devices

    Energy Technology Data Exchange (ETDEWEB)

    Duan, Ya-Hui; Duan, Yu, E-mail: duanyu@jlu.edu.cn; Wang, Xiao; Yang, Dan; Yang, Yong-Qiang; Chen, Ping; Sun, Feng-Bo; Xue, Kai-Wen; Zhao, Yi

    2015-10-01

    Graphical abstract: - Highlights: • An ultra-smooth AgNW film on a flexible photopolymer substrate has been fabricated. • The AgNW film has a low sheet resistance with high transparency and flexibility. • OLEDs based on AgNW:NOA63 substrate can be bent at a radius of curvature of 2 mm. - Abstract: Materials to replace indium tin oxide (ITO) for high transmittance and electrical conductivity are urgently needed. In this paper, we adopted a silver nanowire (AgNW)-photopolymer (NOA63) film as a new platform for flexible optoelectronic devices. This design combined a transparent electrode and a flexible substrate. We utilized this application to obtain flexible organic light-emitting devices (FOLEDs). A peel-off process combined with a spin-coating process created an ultra-smooth silver nanowire anode on a photopolymer substrate. The performance of the device was achieved via the perfect morphology of the AgNW anode, the optimal 5 mg/ml concentration of AgNW solution, and the 45.7 Ω/□ sheet resistance of the AgNW film. The maximum current efficiency of the FOLED is 13 cd/A with stable mechanical flexibility even when bent to a radius of curvature of 2 mm. The outstanding performance of the FOLED with peeled off AgNW anode shows that this approach is a promising alternative to ITO for FOLEDs.

  10. Safety and effectiveness of repeat arterial closure using the AngioSeal device in patients with hepatic malignancy.

    Science.gov (United States)

    Hieb, Robert A; Neisen, Melissa J; Hohenwalter, Eric J; Molnar, Jim A; Rilling, William S

    2008-12-01

    To retrospectively evaluate the safety and effectiveness of the use of the AngioSeal device for repeat arterial closure in patients with hepatic malignancy. A retrospective analysis of patients with hepatic malignancy who had undergone repeated arterial closure with the AngioSeal device was performed. All charts for patients undergoing transarterial chemoembolization or TheraSphere radioembolization were reviewed for the method of hemostasis and the number of arterial closures. A total of 53 patients (58.5% men, 41.5% women; mean age, 58.7 years) had repeat AngioSeal arterial puncture closure after chemoembolization or TheraSphere treatment. Percutaneous closure of the common femoral artery with the AngioSeal device was performed in accordance with the manufacturer's recommendations. The patients were examined for complications on follow-up. Effectiveness was defined by the ability to obtain satisfactory hemostasis. Safety was assessed by the absence of groin complications and by vessel patency on follow-up angiograms of the puncture site obtained at subsequent liver-directed therapy sessions. Fifty-three patients in this study group had a total of 203 common femoral artery punctures. There were a total of 161 closures with the AngioSeal device (79.3%): 58 (36%) single closures and 103 (64.0%) repeat closures. Of the 161 attempts at AngioSeal closure, there was one closure failure in the single-puncture group, yielding a success rate of 98.3%; and one closure failure in the repeat-puncture group, yielding a success rate of 99%. In these two patients, hemostasis was achieved with traditional manual compression without the need for any other device, and no complications were noted. The overall success rate of AngioSeal device closure was 98.7%. The repeat use of the AngioSeal closure device is safe and effective in patients with hepatic malignancy undergoing regional oncologic interventional procedures.

  11. Radioactive waste processing method and device

    International Nuclear Information System (INIS)

    Ozaki, Shigeru; Tateyama, Shinji.

    1998-01-01

    A powdery activated carbon is charged to radioactive liquid wastes to form a mixed slurry. The slurry is subjected to solid/liquid separation, and a high-molecular water absorbent is charged to the separated activated carbon sludge wastes to process them while stirring. The high-molecular water absorbent comprises a graft polymer of starch and acrylonitrile or a cross-linked polymer of sodium acrylate and a cross-linking agent. The high-molecular water absorbing agent is previously charged to a vessel for containing the wasted active carbon sludges. The device of the present invention comprises a filtration device for solid/liquid separation of the mixed slurry, a sludge-containing vessel, a device for charging the high-molecular water absorbent and a sludge stirring device. The device of charging the high-molecular water absorbent comprises a plurality of weighing devices for weighing the change of the weight of the charged products and a conveyor for transferring the sludge-containing vessels. With such a constitution, stable sludge can be obtained, and activated carbon sludge wastes can be burnt without crushing them. (T.M.)

  12. Radiation hazards from horses undergoing scintigraphy using technetium -{sup 99m}

    Energy Technology Data Exchange (ETDEWEB)

    Whitelock, R.G. [Royal Veterinary College, Hatfield (United Kingdom)

    1997-01-01

    This paper quantifies the extent of the radiation hazard to personnel from horses undergoing scintigraphy using technetium{sup 99m} methylene diphosphonate ({sup 99m}Tc{sup m}-MDP). From the data produced it is possible to derive safe working protocols which are comfortably within the legislated limits for whole body doses as set out in the Ionising Radiations Regulations 1985. Measurements were made of the surface and environmental activities which result from individuals undergoing scintigraphic evaluation and also from urine contaminated bedding. The use of both high and low activities in the assessment of the radiation hazard to personnel and owners is considered. (author).

  13. Fundamentals of semiconductor devices

    CERN Document Server

    Lindmayer, Joseph

    1965-01-01

    Semiconductor properties ; semiconductor junctions or diodes ; transistor fundamentals ; inhomogeneous impurity distributions, drift or graded-base transistors ; high-frequency properties of transistors ; band structure of semiconductors ; high current densities and mechanisms of carrier transport ; transistor transient response and recombination processes ; surfaces, field-effect transistors, and composite junctions ; additional semiconductor characteristics ; additional semiconductor devices and microcircuits ; more metal, insulator, and semiconductor combinations for devices ; four-pole parameters and configuration rotation ; four-poles of combined networks and devices ; equivalent circuits ; the error function and its properties ; Fermi-Dirac statistics ; useful physical constants.

  14. Magnetic resonance imaging of implantable cardiac rhythm devices at 3.0 tesla.

    Science.gov (United States)

    Gimbel, J Rod

    2008-07-01

    A relaxation of the prohibition of scanning cardiac rhythm device patients is underway, largely because of the growing experience of safe scanning events at 1.5T. Magnetic resonance imaging (MRI) at 3T is becoming more common and may pose a different risk profile and outcome of MRI of cardiac device patients. No restrictions were placed on pacemaker dependency, region scanned, device type, or manufacturer. Sixteen scans at 3T were performed with an electrophysiologist present on 14 patients with a variety of devices from various manufacturers. An "MRI-S" strategy was used. Multimodal monitoring was required. Device interrogation was performed prior to, immediately after, and 1-3 months after the MRI. For nonpacemaker-dependent device patients, attempts were made to turn all device features off (with OOO programming the goal) conceptually rendering the device "invisible." In pacemaker-dependent patients, the device was programmed to asynchronous mode at highest output for the duration of the scan with the goal of rendering the device conceptually "invulnerable" to MRI effects. The specific absorption rate (SAR) was limited to 2W/kg. All patients were successfully scanned. No arrhythmias were noted. No significant change in the programmed parameters, pacing thresholds, sensing, impedance, or battery parameters was noted. The insertable loop recorder (ILR) recorded prolonged artifactual asystole during MRI. One patient noted chest burning during the scan. Device patients may undergo carefully tailored 3T MRI scans when pre-MRI reprogramming of the device occurs in conjunction with extensive monitoring, supervision, and follow-up.

  15. Containment and surveillance devices

    International Nuclear Information System (INIS)

    Campbell, J.W.; Johnson, C.S.; Stieff, L.R.

    The growing acceptance of containment and surveillance as a means to increase safeguards effectiveness has provided impetus to the development of improved surveillance and containment devices. Five recently developed devices are described. The devices include one photographic and two television surveillance systems and two high security seals that can be verified while installed

  16. Properties of CMOS devices and circuits fabricated on high-resistivity, detector-grade silicon

    International Nuclear Information System (INIS)

    Holland, S.

    1991-11-01

    A CMOS process that is compatible with silicon p-i-n radiation detectors has been developed and characterized. A total of twelve mask layers are used in the process. The NMOS device is formed in a retrograde well while the PMOS device is fabricated directly in the high-resistivity silicon. Isolation characteristics are similar to a standard foundary CMOS process. Circuit performance using 3 μm design rules has been evaluated. The measured propagation delay and power-delay product for a 51-stage ring oscillator was 1.5 ns and 43 fJ, respectively. Measurements on a simple cascode amplifier results in a gain-bandwidth product of 200 MHz at a bias current of 15 μA. The input-referred noise of the cascode amplifier is 20 nV/√Hz at 1 MHz

  17. Fabrication of integrated metallic MEMS devices

    DEFF Research Database (Denmark)

    Yalcinkaya, Arda Deniz; Ravnkilde, Jan Tue; Hansen, Ole

    2002-01-01

    A simple and complementary metal oxide semiconductor (CMOS) compatible fabrication technique for microelectromechanical (MEMS) devices is presented. The fabrication technology makes use of electroplated metal layers. Among the fabricated devices, high quality factor microresonators are characteri......A simple and complementary metal oxide semiconductor (CMOS) compatible fabrication technique for microelectromechanical (MEMS) devices is presented. The fabrication technology makes use of electroplated metal layers. Among the fabricated devices, high quality factor microresonators...

  18. Divertor, thermonuclear device and method of neutralizing high temperature plasma

    International Nuclear Information System (INIS)

    Ikegami, Hideo.

    1995-01-01

    The thermonuclear device comprises a thermonuclear reactor for taking place fusion reactions to emit fusion plasmas, and a divertor made of a hydrogen occluding material, and the divertor is disposed at a position being in contact with the fusion plasmas after nuclear fusion reaction. The divertor is heated by fusion plasmas after nuclear fusion reaction, and hydrogen is released from the hydrogen occluding material as a constituent material. A gas blanket is formed by the released hydrogen to cool and neutralize the supplied high temperature nuclear fusion plasmas. This prevents the high temperature plasmas from hitting against the divertor, elimination of the divertor by melting and evaporation, and solve a problem of processing a divertor activated by neutrons. In addition, it is possible to utilize hydrogen isotopes of fuels effectively and remove unnecessary helium. Inflow of impurities from out of the system can also be prevented. (N.H.)

  19. Micro- and nano-scale optical devices for high density photonic integrated circuits at near-infrared wavelengths

    Science.gov (United States)

    Chatterjee, Rohit

    In this research work, we explore fundamental silicon-based active and passive photonic devices that can be integrated together to form functional photonic integrated circuits. The devices which include power splitters, switches and lenses are studied starting from their physics, their design and fabrication techniques and finally from an experimental standpoint. The experimental results reveal high performance devices that are compatible with standard CMOS fabrication processes and can be easily integrated with other devices for near infrared telecom applications. In Chapter 2, a novel method for optical switching using nanomechanical proximity perturbation technique is described and demonstrated. The method which is experimentally demonstrated employs relatively low powers, small chip footprint and is compatible with standard CMOS fabrication processes. Further, in Chapter 3, this method is applied to develop a hitless bypass switch aimed at solving an important issue in current wavelength division multiplexing systems namely hitless switching of reconfigurable optical add drop multiplexers. Experimental results are presented to demonstrate the application of the nanomechanical proximity perturbation technique to practical situations. In Chapter 4, a fundamental photonic component namely the power splitter is described. Power splitters are important components for any photonic integrated circuits because they help split the power from a single light source to multiple devices on the same chip so that different operations can be performed simultaneously. The power splitters demonstrated in this chapter are based on multimode interference principles resulting in highly compact low loss and highly uniform power splitting to split the power of the light from a single channel to two and four channels. These devices can further be scaled to achieve higher order splitting such as 1x16 and 1x32 power splits. Finally in Chapter 5 we overcome challenges in device

  20. Ion trap device

    Science.gov (United States)

    Ibrahim, Yehia M.; Smith, Richard D.

    2016-01-26

    An ion trap device is disclosed. The device includes a series of electrodes that define an ion flow path. A radio frequency (RF) field is applied to the series of electrodes such that each electrode is phase shifted approximately 180 degrees from an adjacent electrode. A DC voltage is superimposed with the RF field to create a DC gradient to drive ions in the direction of the gradient. A second RF field or DC voltage is applied to selectively trap and release the ions from the device. Further, the device may be gridless and utilized at high pressure.

  1. Real-time computer treatment of THz passive device images with the high image quality

    Science.gov (United States)

    Trofimov, Vyacheslav A.; Trofimov, Vladislav V.

    2012-06-01

    We demonstrate real-time computer code improving significantly the quality of images captured by the passive THz imaging system. The code is not only designed for a THz passive device: it can be applied to any kind of such devices and active THz imaging systems as well. We applied our code for computer processing of images captured by four passive THz imaging devices manufactured by different companies. It should be stressed that computer processing of images produced by different companies requires using the different spatial filters usually. The performance of current version of the computer code is greater than one image per second for a THz image having more than 5000 pixels and 24 bit number representation. Processing of THz single image produces about 20 images simultaneously corresponding to various spatial filters. The computer code allows increasing the number of pixels for processed images without noticeable reduction of image quality. The performance of the computer code can be increased many times using parallel algorithms for processing the image. We develop original spatial filters which allow one to see objects with sizes less than 2 cm. The imagery is produced by passive THz imaging devices which captured the images of objects hidden under opaque clothes. For images with high noise we develop an approach which results in suppression of the noise after using the computer processing and we obtain the good quality image. With the aim of illustrating the efficiency of the developed approach we demonstrate the detection of the liquid explosive, ordinary explosive, knife, pistol, metal plate, CD, ceramics, chocolate and other objects hidden under opaque clothes. The results demonstrate the high efficiency of our approach for the detection of hidden objects and they are a very promising solution for the security problem.

  2. A high resolution scintillating fibre (SCIFI) tracking device with CCD readout

    International Nuclear Information System (INIS)

    Atkinson, M.N.; Crennell, D.J.; Fisher, C.M.; Hughes, P.T.; Kirkby, J.; Fent, J.; Freund, P.; Osthoff, A.; Pretzl, K.

    1987-06-01

    The authors present initial test beam measurements of a high resolution scintillating fibre detector with charge coupled device readout. The analysis procedure is discussed and the performance of the detector and its readout assembly is evaluated. A detected photon density is found along minimum ionising tracks of 2.0 mm -1 , with a straight-line RMS residual of 19.3 +- 2.9 μm, giving rise to a track impact parameter precision of 8.8 +- 2.0 μm. The two-track resolution is found to be 52 μm. (author)

  3. A Study of Dip-Coatable, High-Capacitance Ion Gel Dielectrics for 3D EWOD Device Fabrication

    Directory of Open Access Journals (Sweden)

    Carlos E. Clement

    2017-01-01

    Full Text Available We present a dip-coatable, high-capacitance ion gel dielectric for scalable fabrication of three-dimensional (3D electrowetting-on-dielectric (EWOD devices such as an n × n liquid prism array. Due to the formation of a nanometer-thick electric double layer (EDL capacitor, an ion gel dielectric offers two to three orders higher specific capacitance (c ≈ 10 μF/cm2 than that of conventional dielectrics such as SiO2. However, the previous spin-coating method used for gel layer deposition poses several issues for 3D EWOD device fabrication, particularly when assembling multiple modules. Not only does the spin-coating process require multiple repetitions per module, but the ion gel layer also comes in risks of damage or contamination due to handling errors caused during assembly. In addition, it was observed that the chemical formulation previously used for the spin-coating method causes the surface defects on the dip-coated gel layers and thus leads to poor EWOD performance. In this paper, we alternatively propose a dip-coating method with modified gel solutions to obtain defect-free, functional ion gel layers without the issues arising from the spin-coating method for 3D device fabrication. A dip-coating approach offers a single-step coating solution with the benefits of simplicity, scalability, and high throughput for deposition of high-capacitance gel layers on non-planar EWOD devices. An ion gel solution was prepared by combining the [EMIM][TFSI] ionic liquid and the [P(VDF-HFP] copolymer at various wt % ratios in acetone solvent. Experimental studies were conducted to fully understand the effects of chemical composition ratios in the gel solution and how varying thicknesses of ion gel and Teflon layers affects EWOD performance. The effectiveness and potentiality of dip-coatable gel layers for 3D EWOD devices have been demonstrated through fabricating 5 × 1 arrayed liquid prisms using a single-step dip-coating method. Each prism module has

  4. Effect of high-energy electron beam irradiation on the device characteristics of IGZO-based transparent thin film transistors

    International Nuclear Information System (INIS)

    Moon, Hye Ji; Oh, Hye Ran; Bae, Byung Seong; Yun, Eui Jung; Ryu, Min Ki; Cho, Kyoung Ik

    2012-01-01

    In this study, we investigated the effects of high-energy electron beam irradiation (HEEBI) on the device properties of indium-gallium-zinc-oxide (IGZO)-based transparent thin film transistors (TTFTs). The developed TTFTs had a top gate structure, which used IGZO and Al 2 O 3 films for the active layer and the gate dielectric, respectively. The developed TTFTs were treated with HEEBI in air at RT at an electron beam energy of 0.8 MeV and a dose of 1 x 10 14 electrons/cm 2 . Without the HEEBI treatment, the devices operated in depletion mode with a threshold voltage (V th ) of -11.25 V, a field-effect mobility (μ FE ) of 8.71 cm 2 /Vs, an on-off ratio (I on/off ) of 1.3 x 10 8 and a sub-threshold slope (SS) of 0.3 V/decade. A huge positive-shifted V th of -1 V, a very high μ FE of 420 cm 2 /Vs, a high I on/off of 6.1 x 10 8 , and a lower SS of 0.25 V/decade were achieved for the HEEBI-treated devices, suggesting that the device characteristics of the developed TTFTs were significantly improved by the HEEBI treatment. The best device characteristics, which include I on/off of 8.1 x 10 8 , SS of 0.25 V/decade, V th of +1 V, μ FE of 8.8 cm 2 /Vs, and operation in the enhancement mode without aging, were obtained for the samples that had been annealed after HEEBI treatment. On the basis of the experimental results, we believe that HEEBI treatment can be crucial to develop IGZO-based TFTs with high performance and long-term reliability.

  5. After-heat removing device

    International Nuclear Information System (INIS)

    Iwashige, Kengo; Otsuka, Masaya; Yokoyama, Iwao; Yamakawa, Masanori.

    1990-01-01

    The present invention concerns an after-heat removing device for first reactors. A heat accumulation portion provided in a cooling channel of an after-heat removing device is disposed before a coil-like heat conduction pipe for cooling of the after-heat removing device. During normal reactor operation, the temperature in the heat accumulation portion is near the temperature of the high temperature plenum due to heat conduction and heat transfer from the high temperature plenum. When the reactor is shutdown and the after-heat removing device is started, coolants cooled in the air cooler start circulation. The coolants arriving at the heat accumulation portion deprive heat from the heat accumulation portion and, ion turn, increase their temperature and then reach the cooling coil. Subsequently, the heat calorie possessed in the heat accumulation portion is reduced and the after-heat removing device is started for the operation at a full power. This can reduce the thermal shocks applied to the cooling coil or structures in a reactor vessel upon starting the after-heat removing device. (I.N.)

  6. Microfabricated Devices for Sample Extraction, Concentrations, and Related Sample Processing Technologies

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Gang; Lin, Yuehe

    2006-12-01

    This is an invited book chapter. As with other analytical techniques, sample pretreatments, sample extraction, sample introduction, and related techniques are of extreme importance for micro-electro-mechanical systems (MEMS). Bio-MEMS devices and systems start with a sampling step. The biological sample then usually undergoes some kinds of sample preparation steps before the actual analysis. These steps may involve extracting the target sample from its matrix, removing interferences from the sample, derivatizing the sample to detectable species, or performing a sample preconcentration step. The integration of the components for sample pretreatment into microfluidic devices represents one of the remaining the bottle-neck towards achieving true miniaturized total analysis systems (?TAS). This chapter provides a thorough state-of-art of the developments in this field to date.

  7. Nuclear fuel shipping inspection device

    International Nuclear Information System (INIS)

    Takahashi, Toshio; Hada, Koji.

    1988-01-01

    Purpose: To provide an nuclear fuel shipping inspection device having a high detection sensitivity and capable of obtaining highly reliable inspection results. Constitution: The present invention concerns a device for distinguishing a fuel assembly having failed fuel rods in LMFBR type reactors. Coolants in a fuel assembly to be inspected are collected by a sampling pipeway and transferred to a filter device. In the filter device, granular radioactive corrosion products (CP) in the coolants are captured, to reduce the background. The coolants, after being passed through the filter device, are transferred to an FP catching device and gamma-rays of iodine and cesium nuclides are measured in FP radiation measuring device. Subsequently, the coolants transferred to a degasing device to separate rare gas FP in the coolants from the liquid phase. In a case if rare gas fission products are detected by the radiation detector, it means that there is a failed fuel rod in the fuel assembly to be inspected. Since the CP and the soluble FP are separated and extracted for the radioactivity measurement, the reliability can be improved. (Kamimura, M.)

  8. Automatic liquid nitrogen feeding device

    International Nuclear Information System (INIS)

    Gillardeau, J.; Bona, F.; Dejachy, G.

    1963-01-01

    An automatic liquid nitrogen feeding device has been developed (and used) in the framework of corrosion tests realized with constantly renewed uranium hexafluoride. The issue was to feed liquid nitrogen to a large capacity metallic trap in order to condensate uranium hexafluoride at the exit of the corrosion chambers. After having studied various available devices, a feeding device has been specifically designed to be robust, secure and autonomous, as well as ensuring a high liquid nitrogen flowrate and a highly elevated feeding frequency. The device, made of standard material, has been used during 4000 hours without any problem [fr

  9. Claims in vapour device (e-cigarette) regulation: A Narrative Policy Framework analysis.

    Science.gov (United States)

    O'Leary, Renée; Borland, Ron; Stockwell, Tim; MacDonald, Marjorie

    2017-06-01

    The electronic cigarette or e-cigarette (vapour device) is a consumer product undergoing rapid growth, and governments have been adopting regulations on the sale of the devices and their nicotine liquids. Competing claims about vapour devices have ignited a contentious debate in the public health community. What claims have been taken up in the state arena, and how have they possibly influenced regulatory outcomes? This study utilized Narrative Policy Framework to analyze the claims made about vapour devices in legislation recommendation reports from Queensland Australia, Canada, and the European Union, and the 2016 deeming rule legislation from the United States, and examined the claims and the regulatory outcomes in these jurisdictions. The vast majority of claims in the policy documents represented vapour devices as a threat: an unsafe product harming the health of vapour device users, a gateway product promoting youth tobacco uptake, and a quasi-tobacco product impeding tobacco control. The opportunity for vapour devices to promote cessation or reduce exposure to toxins was very rarely presented, and these positive claims were not discussed at all in two of the four documents studied. The dominant claims of vapour devices as a public health threat have supported regulations that have limited their potential as a harm reduction strategy. Future policy debates should evaluate the opportunities for vapour devices to decrease the health and social burdens of the tobacco epidemic. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Organic bistable light-emitting devices

    Science.gov (United States)

    Ma, Liping; Liu, Jie; Pyo, Seungmoon; Yang, Yang

    2002-01-01

    An organic bistable device, with a unique trilayer structure consisting of organic/metal/organic sandwiched between two outmost metal electrodes, has been invented. [Y. Yang, L. P. Ma, and J. Liu, U.S. Patent Pending, U.S. 01/17206 (2001)]. When the device is biased with voltages beyond a critical value (for example 3 V), the device suddenly switches from a high-impedance state to a low-impedance state, with a difference in injection current of more than 6 orders of magnitude. When the device is switched to the low-impedance state, it remains in that state even when the power is off. (This is called "nonvolatile" phenomenon in memory devices.) The high-impedance state can be recovered by applying a reverse bias; therefore, this bistable device is ideal for memory applications. In order to increase the data read-out rate of this type of memory device, a regular polymer light-emitting diode has been integrated with the organic bistable device, such that it can be read out optically. These features make the organic bistable light-emitting device a promising candidate for several applications, such as digital memories, opto-electronic books, and recordable papers.

  11. Radiation emitting devices regulations

    International Nuclear Information System (INIS)

    1970-01-01

    The Radiation Emitting Devices Regulations are the regulations referred to in the Radiation Emitting Devices Act and relate to the operation of devices. They include standards of design and construction, standards of functioning, warning symbol specifications in addition to information relating to the seizure and detention of machines failing to comply with the regulations. The radiation emitting devices consist of the following: television receivers, extra-oral dental x-ray equipment, microwave ovens, baggage inspection x-ray devices, demonstration--type gas discharge devices, photofluorographic x-ray equipment, laser scanners, demonstration lasers, low energy electron microscopes, high intensity mercury vapour discharge lamps, sunlamps, diagnostic x-ray equipment, ultrasound therapy devices, x-ray diffraction equipment, cabinet x-ray equipment and therapeutic x-ray equipment

  12. The Role of Electrode Contamination and the Effects of Cleaning and Conditioning on the Performance of High-Energy, Pulsed-Power Devices

    Energy Technology Data Exchange (ETDEWEB)

    Cuneo, M.E.

    1998-11-10

    High-energy pulsed-power devices routinely access field strengths above those at which broad-area, cathode-initiated, high-voltage vacuum-breakdown occur. Examples include magnetically-insulated-transmission lines and current convolutes, high-current-density electron and ion diodes, high-power microwave devices, and cavities and other structures for electrostatic and RF accelerators. Energy deposited in anode surfaces may exceed anode plasma thermal-desorption creation thresholds on the time-scale of the pulse. Stimulated resorption by electron or photon bombardment can also lead to plasma formation on electrode or insulator surfaces. Device performance is limited above these thresholds, particularly impulse length and energy, by the formation and expansion of neutral and plasma layers formed, primarily from electrode contaminants. In-situ conditioning tech&ques to modify and eliminate the contaminants through multiple high-voltage pukes, low base pressures, RF discharge cleaning, heating, surface coatings, and ion- and electron-beam surface treatment allow access to new regimes of performance through control of plasma formation and modification of the plasma properties. Experimental and theoretical progress from a variety of devices and small scale experiments with a variety of treatment methods will be reviewed and recommendations given for future work.

  13. Radiation detection device

    International Nuclear Information System (INIS)

    Peschmann, Kristian.

    1982-01-01

    A radiation detector suitable for use in computer tomography device has an ionization chamber which comprises a high voltage electrode, a collector electrode, a high voltage source having two terminals, one connected to the high voltage electrode, current measuring means having two terminals, one connected to the high voltage source and the other to the collector electrode, and an auxilliary electrode near and parallel to the entrance window of the device, having one adjacent to the high voltage electrode and the other adjacent but not connected to the collector electrode. The auxilliary electrode is connected to the high voltage source. In this way the electric field between the high voltage and collector electrodes is made homogeneous in the vicinity of the auxilliary electrode, improving the measuring speed of the detector

  14. Alternative Solder Bond Packaging Approach for High-Voltage (HV) Pulsed Power Devices

    Science.gov (United States)

    2016-09-01

    triggered into the ON-state with a fiber - optic transmitter once the capacitor has been charged up to the desired voltage of choice with a power supply...substrate, which results in a much higher conductivity compared to highly doped p-type substrates in SiC (Fig. 1). The anode layer was etched using...reactive ion etch and then the mesa of the device was etched for total isolation. The gate contact implant was followed using nitrogen in a box

  15. Thermostating highly confined fluids.

    Science.gov (United States)

    Bernardi, Stefano; Todd, B D; Searles, Debra J

    2010-06-28

    In this work we show how different use of thermostating devices and modeling of walls influence the mechanical and dynamical properties of confined nanofluids. We consider a two dimensional fluid undergoing Couette flow using nonequilibrium molecular dynamics simulations. Because the system is highly inhomogeneous, the density shows strong fluctuations across the channel. We compare the dynamics produced by applying a thermostating device directly to the fluid with that obtained when the wall is thermostated, considering also the effects of using rigid walls. This comparison involves an analysis of the chaoticity of the fluid and evaluation of mechanical properties across the channel. We look at two thermostating devices with either rigid or vibrating atomic walls and compare them with a system only thermostated by conduction through vibrating atomic walls. Sensitive changes are observed in the xy component of the pressure tensor, streaming velocity, and density across the pore and the Lyapunov localization of the fluid. We also find that the fluid slip can be significantly reduced by rigid walls. Our results suggest caution in interpreting the results of systems in which fluid atoms are thermostated and/or wall atoms are constrained to be rigid, such as, for example, water inside carbon nanotubes.

  16. A microfluidic-based lid device for conventional cell culture dishes to automatically control oxygen level.

    Science.gov (United States)

    Lee, Seung Yeob; Yang, Sung

    2018-04-25

    Most conventional hypoxic cell culture systems undergo reoxygenation during experimental manipulations, resulting in undesirable effects including the reduction of cell viability. A lid device was developed herein for conventional cell culture dishes to resolve this limitation. The integration of multilayered microfluidic channels inside a thin membrane was designed to prevent the reoxygenation caused by reagent infusion and automatically control the oxygen level. The experimental data clearly show the reducibility of the dissolved oxygen in the infusing reagent and the controllability of the oxygen level inside the dish. The feasibility of the device for hypoxia studies was confirmed by HIF-1α experiments. Therefore, the device could be used as a compact and convenient hypoxic cell culture system to prevent reoxygenation-related issues.

  17. Efficacy and safety of intravitreal bevacizumab in eyes with neovascular glaucoma undergoing Ahmed glaucoma valve implantation: 2-year follow-up.

    Science.gov (United States)

    Arcieri, Enyr S; Paula, Jayter S; Jorge, Rodrigo; Barella, Kleyton A; Arcieri, Rafael S; Secches, Danilo J; Costa, Vital P

    2015-02-01

    To evaluate the efficacy and safety of intravitreal bevacizumab (IVB) in eyes with neovascular glaucoma (NVG) undergoing Ahmed glaucoma valve (AGV) implantation. This was a multicentre, prospective, randomized clinical trial that enrolled 40 patients with uncontrolled neovascular glaucoma that had undergone panretinal photocoagulation and required glaucoma drainage device implantation. Patients were randomized to receive IVB (1.25 mg) or not during Ahmed valve implant surgery. Injections were administered intra-operatively, and 4 and 8 weeks after surgery. After a mean follow-up of 2.25 ± 0.67 years (range 1.5-3 years), both groups showed a significant decrease in IOP (p glaucoma undergoing Ahmed glaucoma valve implantation. There is a trend to slightly lower IOPs and number of medications with IVB use during AGV implantation for neovascular glaucoma. © 2014 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  18. Understanding the C-pulse device and its potential to treat heart failure.

    Science.gov (United States)

    Sales, Virna L; McCarthy, Patrick M

    2010-03-01

    The Sunshine Heart C-Pulse (C-Pulse; Sunshine Heart Inc., Tustin, CA) device is an extra-aortic implantable counterpulsation pump designed as a non-blood contacting ambulatory heart assist device, which may provide relief from symptoms for class II-III congestive heart failure patients. It has a comparable hemodynamic augmentation to intra-aortic balloon counterpulsation devices. The C-Pulse cuff is implanted through a median sternotomy, secured around the ascending aorta, and pneumatically driven by an external system controller. Pre-clinical studies in the acute pig model, and initial temporary clinical studies in patients undergoing off-pump coronary bypass surgery have shown substantial increase in diastolic perfusion of the coronary vessels, which translated to a favorable improvement in ventricular function. A U.S. prospective multi-center trial to evaluate the safety and efficacy of the C-Pulse in class III patients with moderate heart failure is now in progress.

  19. Method and device for secure, high-density tritium bonded with carbon

    Science.gov (United States)

    Wertsching, Alan Kevin; Trantor, Troy Joseph; Ebner, Matthias Anthony; Norby, Brad Curtis

    2016-04-05

    A method and device for producing secure, high-density tritium bonded with carbon. A substrate comprising carbon is provided. A precursor is intercalated between carbon in the substrate. The precursor intercalated in the substrate is irradiated until at least a portion of the precursor, preferably a majority of the precursor, is transmutated into tritium and bonds with carbon of the substrate forming bonded tritium. The resulting bonded tritium, tritium bonded with carbon, produces electrons via beta decay. The substrate is preferably a substrate from the list of substrates consisting of highly-ordered pyrolytic graphite, carbon fibers, carbon nanotunes, buckministerfullerenes, and combinations thereof. The precursor is preferably boron-10, more preferably lithium-6. Preferably, thermal neutrons are used to irradiate the precursor. The resulting bonded tritium is preferably used to generate electricity either directly or indirectly.

  20. Giant magneto-resistance devices

    CERN Document Server

    Hirota, Eiichi; Inomata, Koichiro

    2002-01-01

    This book deals with the application of giant magneto-resistance (GMR) effects to electronic devices. It will appeal to engineers and graduate students in the fields of electronic devices and materials. The main subjects are magnetic sensors with high resolution and magnetic read heads with high sensitivity, required for hard-disk drives with recording densities of several gigabytes. Another important subject is novel magnetic random-access memories (MRAM) with non-volatile non-destructive and radiation-resistant characteristics. Other topics include future GMR devices based on bipolar spin transistors, spin field-effect transistors (FETs) and double-tunnel junctions.

  1. Thomson scattering measuring device using high sensitivity photomultipliers: 16% up to 860nm

    International Nuclear Information System (INIS)

    Hesse, M.

    1976-03-01

    Photomultipliers with high quantum efficiency were used to observe the entire rubis laser light spectrum scattered by a plasma. The optical and electronic acquisition device used to study this spectrum is described. The spectra obtained revealed a dissymmetry larger than that expected from relativistic theory. These results could not be interpreted. The diagnostic sensitivity allows the measurement of low electron densities (2.10 12 ecm -3 ) [fr

  2. Articulating feedstock delivery device

    Science.gov (United States)

    Jordan, Kevin

    2013-11-05

    A fully articulable feedstock delivery device that is designed to operate at pressure and temperature extremes. The device incorporates an articulating ball assembly which allows for more accurate delivery of the feedstock to a target location. The device is suitable for a variety of applications including, but not limited to, delivery of feedstock to a high-pressure reaction chamber or process zone.

  3. Baking exhaustion device in thermonuclear device

    Energy Technology Data Exchange (ETDEWEB)

    Kondo, Mitsunori.

    1987-02-02

    Purpose: To rapidly remove tritium and impurity from the vacuum region in the access port of the baking exhaustion device in a thermonuclear device. Constitution: Each of the gaps at the boundary between a fixed shielding member and a blanket module and at the boundary between the blanket and a divertor is made extremely small so as to minimize the neutron streaming from plasmas. Accordingly, in the case of evacuating the vacuum region in the access port, the gap conductance is extremely poor and the exhaustion speed is low. Then, baking pipeways for flowing high temperature fluids are embedded to the surface layer at the position facing to the vacuum region and the plasma evacuation duct and the vacuum region are connected with an evacuation duct of the access port. By flowing high temperature fluids in the pipeways and conducting evacuation, baking exhaustion can be carried out rapidly. (Kamimura, M.).

  4. Repairing method and device for thermonuclear device

    International Nuclear Information System (INIS)

    Sakurai, Akiko; Masumoto, Hiroshi; Tachikawa, Nobuo.

    1995-01-01

    The present invention provides a method of and a device for repairing a first wall and a divertor disposed in a vacuum vessel of a thermonuclear device. Namely, an armour tile of the divertor secured, by a brazing material, in a vacuum vessel of the thermonuclear device in which high temperature plasmas of deuterium and tritium are confined to cause fusion reaction is induction-heated or heated by microwaves to melt the brazing material. Only the armour tile is thus exchanged by its attachment/detachment. This device comprises, in the vacuum vessel, an armour tile attaching/detaching manipulator and a repairing manipulator comprising a heating manipulator having induction heating coils at the top end thereof. Induction heating coils are connected to an AC power source. According to the present invention, the armour tile is exchanged without taking the divertor out of the vacuum vessel. Therefore, cutting of a divertor cooling tube for taking the divertor out of the vacuum vessel and re-welding of the divertor for attaching it to the vacuum vessel again are no more necessary. (I.S.)

  5. Materials and devices with applications in high-end organic transistors

    International Nuclear Information System (INIS)

    Takeya, J.; Uemura, T.; Sakai, K.; Okada, Y.

    2014-01-01

    The development of functional materials typically benefits from an understanding of the microscopic mechanisms by which those materials operate. To accelerate the development of organic semiconductor devices with industrial applications in flexible and printed electronics, it is essential to elucidate the mechanisms of charge transport associated with molecular-scale charge transfer. In this study, we employed Hall effect measurements to differentiate coherent band transport from site-to-site hopping. The results of tests using several different molecular systems as the active semiconductor layers demonstrate that high-mobility charge transport in recently-developed solution-crystallized organic transistors is the result of a band-like mechanism. These materials, which have the potential to be organic transistors exhibiting the highest speeds ever obtained, are significantly different from the conventional lower-mobility organic semiconductors with incoherent hopping-like transport mechanisms which were studied in the previous century. They may be categorized as “high-end” organic semiconductors, characterized by their coherent electronic states and high values of mobility which are close to or greater than 10 cm 2 /Vs. - Highlights: • Transport in high-mobility solution-crystallized organic transistors is band-like. • High-end organic semiconductors carry coherent electrons with mobility > 10 cm 2 /Vs. • Hall-effect measurement differentiates coherent band transport from hopping. • We found an anomalous pressure effect in organic semiconductors

  6. Modeling High Frequency Semiconductor Devices Using Maxwell's Equations

    National Research Council Canada - National Science Library

    El-Ghazaly, Samier

    1999-01-01

    .... In this research, we first replaced the conventional semiconductor device models, which are based on Poisson's Equation as a semiconductor model, with a new one that uses the full-wave electro...

  7. A Review on Natural Ventilation-enabling Façade Noise Control Devices for Congested High-Rise Cities

    Directory of Open Access Journals (Sweden)

    Shiu-Keung Tang

    2017-02-01

    Full Text Available This review summarizes the current status of the research and development of natural ventilation-enabling noise control devices for use on the façades of high-rise residential buildings in congested cities. These devices are important for a sustainable urbanized city, as they are supposed to offer good acoustical protection to citizens, allowing for an acceptable level of natural ventilation inside residential units; energy for mechanical ventilation can then be saved. From the information presented in the existing literature, it is concluded that protrusive devices, such as lintels and balconies, are not effective noise screening devices, even if they are installed with sound absorbers and/or reflectors, under the effect of city reverberation. On the contrary, plenum windows and similar structures, which are plenum structures with a staggered air inlet and outlet, are interesting alternatives that are worth rigorous considerations.

  8. Management of severe ischemic cardiomyopathy: left ventricular assist device as destination therapy versus conventional bypass and mitral valve surgery.

    Science.gov (United States)

    Maltais, Simon; Tchantchaleishvili, Vahtang; Schaff, Hartzell V; Daly, Richard C; Suri, Rakesh M; Dearani, Joseph A; Topilsky, Yan; Stulak, John M; Joyce, Lyle D; Park, Soon J

    2014-04-01

    Patients with severe ischemic cardiomyopathy (left ventricular ejection fraction assist device as destination therapy is reserved for patients who are too high risk for conventional surgery. We evaluated our outcomes with conventional surgery within this population and the comparative effectiveness of these 2 therapies. We identified patients who underwent conventional surgery or left ventricular assist device as destination therapy for severe ischemic cardiomyopathy (left ventricular ejection fraction assist device as destination therapy. We compared baseline patient characteristics and outcomes in terms of end-organ function and survival. A total of 88 patients were identified; 55 patients underwent conventional surgery (63%), and 33 patients (37%) received a left ventricular assist device as destination therapy. Patients who received left ventricular assist device as destination therapy had the increased prevalence of renal failure, inotrope dependency, and intra-aortic balloon support. Patients undergoing conventional surgery required longer ventilatory support, and patients receiving a left ventricular assist device required more reoperation for bleeding. Mortality rates were similar between the 2 groups at 30 days (7% in the conventional surgery group vs 3% in the left ventricular assist device as destination therapy group, P = .65) and at 1 year (22% in the conventional surgery group vs 15% in the left ventricular assist device as destination therapy group, P = .58). There was a trend toward improved survival in patients receiving a left ventricular assist device compared with the propensity-matched groups at 1 year (94% vs 71%, P = .171). The operative mortality and early survival after conventional surgery seem to be acceptable. For inoperable or prohibitive-risk patients, left ventricular assist device as destination therapy can be offered with similar outcomes. Copyright © 2014 The American Association for Thoracic Surgery. Published by Mosby

  9. High-stringency screening of target-binding partners using a microfluidic device

    Science.gov (United States)

    Soh, Hyongsok; Lou, Xinhui; Lagally, Eric

    2015-12-01

    The invention provides a method of screening a library of candidate agents by contacting the library with a target in a reaction mixture under a condition of high stringency, wherein the target includes a tag that responds to a controllable force applied to the tag, and passing the members of the library through a microfluidic device in a manner that exposes the library members to the controllable force, thereby displacing members of the library that are bound to the target relative to their unbound counterparts. Kits and systems for use with the methods of the invention are also provided.

  10. Rapid Prototyping of a Smart Device-based Wireless Reflectance Photoplethysmograph

    Science.gov (United States)

    Ghamari, M.; Aguilar, C.; Soltanpur, C.; Nazeran, H.

    2017-01-01

    This paper presents the design, fabrication, and testing of a wireless heart rate (HR) monitoring device based on photoplethysmography (PPG) and smart devices. PPG sensors use infrared (IR) light to obtain vital information to assess cardiac health and other physiologic conditions. The PPG data that are transferred to a computer undergo further processing to derive the Heart Rate Variability (HRV) signal, which is analyzed to generate quantitative markers of the Autonomic Nervous System (ANS). The HRV signal has numerous monitoring and diagnostic applications. To this end, wireless connectivity plays an important role in such biomedical instruments. The photoplethysmograph consists of an optical sensor to detect the changes in the light intensity reflected from the illuminated tissue, a signal conditioning unit to prepare the reflected light for further signal conditioning through amplification and filtering, a low-power microcontroller to control and digitize the analog PPG signal, and a Bluetooth module to transmit the digital data to a Bluetooth-based smart device such as a tablet. An Android app is then used to enable the smart device to acquire and digitally display the received analog PPG signal in real-time on the smart device. This article is concluded with the prototyping of the wireless PPG followed by the verification procedures of the PPG and HRV signals acquired in a laboratory environment. PMID:28959119

  11. Rapid Prototyping of a Smart Device-based Wireless Reflectance Photoplethysmograph.

    Science.gov (United States)

    Ghamari, M; Aguilar, C; Soltanpur, C; Nazeran, H

    2016-03-01

    This paper presents the design, fabrication, and testing of a wireless heart rate (HR) monitoring device based on photoplethysmography (PPG) and smart devices. PPG sensors use infrared (IR) light to obtain vital information to assess cardiac health and other physiologic conditions. The PPG data that are transferred to a computer undergo further processing to derive the Heart Rate Variability (HRV) signal, which is analyzed to generate quantitative markers of the Autonomic Nervous System (ANS). The HRV signal has numerous monitoring and diagnostic applications. To this end, wireless connectivity plays an important role in such biomedical instruments. The photoplethysmograph consists of an optical sensor to detect the changes in the light intensity reflected from the illuminated tissue, a signal conditioning unit to prepare the reflected light for further signal conditioning through amplification and filtering, a low-power microcontroller to control and digitize the analog PPG signal, and a Bluetooth module to transmit the digital data to a Bluetooth-based smart device such as a tablet. An Android app is then used to enable the smart device to acquire and digitally display the received analog PPG signal in real-time on the smart device. This article is concluded with the prototyping of the wireless PPG followed by the verification procedures of the PPG and HRV signals acquired in a laboratory environment.

  12. Surface Effects and Challenges for Application of Piezoelectric Langasite Substrates in Surface Acoustic Wave Devices Caused by High Temperature Annealing under High Vacuum.

    Science.gov (United States)

    Seifert, Marietta; Rane, Gayatri K; Kirbus, Benjamin; Menzel, Siegfried B; Gemming, Thomas

    2015-12-19

    Substrate materials that are high-temperature stable are essential for sensor devices which are applied at high temperatures. Although langasite is suggested as such a material, severe O and Ga diffusion into an O-affine deposited film was observed during annealing at high temperatures under vacuum conditions, leading to a damage of the metallization as well as a change of the properties of the substrate and finally to a failure of the device. Therefore, annealing of bare LGS (La 3 Ga 5 SiO 14 ) substrates at 800 ∘ C under high vacuum conditions is performed to analyze whether this pretreatment improves the suitability and stability of this material for high temperature applications in vacuum. To reveal the influence of the pretreatment on the subsequently deposited metallization, RuAl thin films are used as they are known to oxidize on LGS at high temperatures. A local study of the pretreated and metallized substrates using transmission electron microscopy reveals strong modification of the substrate surface. Micro cracks are visible. The composition of the substrate is strongly altered at those regions. Severe challenges for the application of LGS substrates under high-temperature vacuum conditions arise from these substrate damages, revealing that the pretreatment does not improve the applicability.

  13. Surface Effects and Challenges for Application of Piezoelectric Langasite Substrates in Surface Acoustic Wave Devices Caused by High Temperature Annealing under High Vacuum

    Directory of Open Access Journals (Sweden)

    Marietta Seifert

    2015-12-01

    Full Text Available Substrate materials that are high-temperature stable are essential for sensor devices which are applied at high temperatures. Although langasite is suggested as such a material, severe O and Ga diffusion into an O-affine deposited film was observed during annealing at high temperatures under vacuum conditions, leading to a damage of the metallization as well as a change of the properties of the substrate and finally to a failure of the device. Therefore, annealing of bare LGS (La 3 Ga 5 SiO 14 substrates at 800 ∘ C under high vacuum conditions is performed to analyze whether this pretreatment improves the suitability and stability of this material for high temperature applications in vacuum. To reveal the influence of the pretreatment on the subsequently deposited metallization, RuAl thin films are used as they are known to oxidize on LGS at high temperatures. A local study of the pretreated and metallized substrates using transmission electron microscopy reveals strong modification of the substrate surface. Micro cracks are visible. The composition of the substrate is strongly altered at those regions. Severe challenges for the application of LGS substrates under high-temperature vacuum conditions arise from these substrate damages, revealing that the pretreatment does not improve the applicability.

  14. Study on pulsed-discharge devices with high current rising rate for point spot short-wavelength source in dense plasma observations

    International Nuclear Information System (INIS)

    Tachinami, Fumitaka; Anzai, Nobuyuki; Sasaki, Toru; Kikuchi, Takashi; Harada, Nob.

    2014-01-01

    A pulsed-power generator with high current rise based on a pulse-forming-network was studied toward generating intense point-spot X-ray source. To obtain the high rate of current rise, we have designed the compact discharge device with low circuit inductance. The results indicate that the inductance of the compact discharge device was dominated by a gap switch inductance. To reduce the gap switch inductance and operation voltage, the feasible gap switch inductance in the vacuum chamber has been estimated by the circuit simulation. The gap switch inductance can be reduced by the lower pressure operation. It means that the designed discharge device achieves the rate of current rise of 10 12 A/s

  15. Molecular beam epitaxy for high-performance Ga-face GaN electron devices

    International Nuclear Information System (INIS)

    Kaun, Stephen W; Speck, James S; Wong, Man Hoi; Mishra, Umesh K

    2013-01-01

    Molecular beam epitaxy (MBE) has emerged as a powerful technique for growing GaN-based high electron mobility transistor (HEMT) epistructures. Over the past decade, HEMT performance steadily improved, mainly through the optimization of device fabrication processes. Soon, HEMT performance will be limited by the crystalline quality of the epistructure. MBE offers heterostructure growth with highly abrupt interfaces, low point defect concentrations, and very low carbon and hydrogen impurity concentrations. Minimizing parasitic leakage pathways and resistances is essential in the growth of HEMTs for high-frequency and high-power applications. Through growth on native substrates with very low threading dislocation density, low-leakage HEMTs with very low on-resistance can be realized. Ga-rich plasma-assisted MBE (PAMBE) has been studied extensively, and it is clear that this technique has inherent limitations, including a high density of leakage pathways and a very small growth parameter space. Relatively new MBE growth techniques—high-temperature N-rich PAMBE and ammonia-based MBE—are being developed to circumvent the shortcomings of Ga-rich PAMBE. (invited review)

  16. High energy permanent magnets - Solutions to high performance devices

    International Nuclear Information System (INIS)

    Ma, B.M.; Willman, C.J.

    1986-01-01

    Neodymium iron boron magnets are a special class of magnets providing the highest level of performance with the least amount of material. Crucible Research Center produced the highest energy product magnet of 45 MGOe - a world record. Commercialization of this development has already taken place. Crucible Magnetics Division, located in Elizabethtown, Kentucky, is currently manufacturing and marketing six different grades of NdFeB magnets. Permanent magnets find application in motors, speakers, electron beam focusing devices for military and Star Wars. The new NdFeB magnets are of considerable interest for a wide range of applications

  17. Improved glucose tolerance after high-load strength training in patients undergoing dialysis

    DEFF Research Database (Denmark)

    Mølsted, Stig; Harrison, Adrian Paul; Eidemak, Inge

    2013-01-01

    glucose tolerance (n = 9). Conclusion: The conducted strength training was associated with a significant improvement in glucose tolerance in patients with impaired glucose tolerance or type 2 diabetes undergoing dialysis. The effect was apparently not associated with muscle hypertrophy, whereas the muscle...... a week. Muscle fiber size, composition and capillary density were analyzed in biopsies obtained in the vastus lateralis muscle. Glucose tolerance and the insulin response were measured by a 2-hour oral glucose tolerance test. Results: All outcome measures remained unchanged during the control period....... After strength training the relative area of type 2X fibers was decreased. Muscle fiber size and capillary density remained unchanged. After the strength training, insulin concentrations were significantly lower in patients with impaired glucose tolerance or type 2 diabetes (n = 14) (fasting insulin...

  18. Highly functional tunnelling devices integrated in 3D

    DEFF Research Database (Denmark)

    Wernersson, Lars-Erik; Lind, Erik; Lindström, Peter

    2003-01-01

    a new type of tunnelling transistor, namely a resonant-tunnelling permeable base transistor. A simple model based on a piece-wise linear approximation is used in Cadence to describe the current-voltage characteristics of the transistor. This model is further introduced into a small signal equivalent...... simultaneously on both tunnelling structures and the obtained characteristics are the result of the interplay between the two tunnelling structures and the gate. An equivalent circuit model is developed and we show how this interaction influences the current-voltage characteristics. The gate may be used......We present a new technology for integrating tunnelling devices in three dimensions. These devices are fabricated by the combination of the growth of semiconductor heterostructures with the controlled introduction of metallic elements into an epitaxial layer by an overgrowth technique. First, we use...

  19. Tooling device design for vibration-assisted high speed shaping of PMMA

    International Nuclear Information System (INIS)

    Mostofa, Md. Golam; Noh, J. H.; Kim, H. Y.; Ahn, J. H.; Kang, D. B.

    2010-01-01

    PMMA optical components that are used as one of the most important parts of high precision equipment and machines are increasingly replacing the glass due to the various advantages of PMMA. Especially in Light Guide Panels, the PMMA sheet that is used in Liquid Crystal Displays plays an important role in scattering the incident light and requires very fine machining as the sheet is directly related to the optical characteristics of the panels. The High Speed End milling and High Speed Shaping processes that are widely adopted and applied to the precise machining of Light Incident Plane still have quality problems, such as cracks, breakages, poor waviness, and straightness. This paper presents the tooling device design for machining a Light Incident Plane through vibration-assisted High Speed Shaping for increasing the optical quality by minimizing the above-mentioned problems. The cutting tool and the tool post presented in this paper are designed by the authors to increase the magnitude of the cutting stroke by adopting the resonant frequency without weakening the stiffness and to reduce vibrations during even high speed feeding. The dynamic characteristics of the cutting tool and the tool post are evaluated through simulation and experiment as well. The results reveal very appropriate dynamic characteristics for vibration-assisted High Speed Shaping

  20. High ionization radiation field remote visualization device - shielding requirements

    International Nuclear Information System (INIS)

    Fernandez, Antonio P. Rodrigues; Omi, Nelson M.; Silveira, Carlos Gaia da; Calvo, Wilson A. Pajero

    2011-01-01

    The high activity sources manipulation hot-cells use special and very thick leaded glass windows. This window provides a single sight of what is being manipulated inside the hot-cell. The use of surveillance cameras would replace the leaded glass window, provide other sights and show more details of the manipulated pieces, using the zoom capacity. Online distant manipulation may be implemented, too. The limitation is their low ionizing radiation resistance. This low resistance also limited the useful time of robots made to explore or even fix problematic nuclear reactor core, industrial gamma irradiators and high radioactive leaks. This work is a part of the development of a high gamma field remote visualization device using commercial surveillance cameras. These cameras are cheap enough to be discarded after the use for some hours of use in an emergency application, some days or some months in routine applications. A radiation shield can be used but it cannot block the camera sight which is the shield weakness. Estimates of the camera and its electronics resistance may be made knowing each component behavior. This knowledge is also used to determine the optical sensor type and the lens material, too. A better approach will be obtained with the commercial cameras working inside a high gamma field, like the one inside of the IPEN Multipurpose Irradiator. The goal of this work is to establish the radiation shielding needed to extend the camera's useful time to hours, days or months, depending on the application needs. (author)

  1. Anesthesia for gastrointestinal endoscopy in patients with left ventricular assist devices: Initial experience with 68 procedures

    Directory of Open Access Journals (Sweden)

    Basavana G Goudra

    2013-01-01

    Full Text Available Aims and Objectives: Continuous flow left ventricular assist devices (LVAD have emerged as a reliable treatment option for heart failure. Because of bleeding secondary to anticoagulation, these patients present frequently for gastrointestinal (GI endoscopy. The presently available literature on perioperative management of these patients is extremely limited and is primarily based upon theoretical principles. Materials and Methods: Perioperative records of patients with LVAD undergoing (GI endoscopy between 2008 and 2012 were reviewed. Patient, device and procedure specific information was analyzed. Results: A total of 105 LVADs were implanted, and 68 procedures were performed in 39 patients. The most common indication was GI bleed (48/68, with yearly risk of 8.57% per patient. A total of 63 procedures were performed under deep sedation, with five procedures requiring general anesthesia. Intra-procedure hypotension was managed by fluids and (or vasopressors/inotropes (phenylephrine, ephedrine or milrinone guided by plethysmographic waveform, non-invasive blood pressure (NIBP and LVADs pulsatility index (for HeartMate II/flow pulsatility (for HeartWare. No patient required invasive monitoring and both NIBP and pulse oximeter could be reliably used for monitoring (and guided management in all patients due to the presence of native heart′s pulsatile output. Conclusion: In the presence of residual heart function, with optimal device settings, non-invasive hemodynamic monitoring can be reliably used in these patients while undergoing GI endoscopy under general anesthesia or monitored anesthesia care. Transient hypotensive episodes respond well to fluids/vasopressors without the need of increasing device speed that can be detrimental.

  2. COMPARISON OF ANTIEMETIC EFFICACY OF ONDANSETRON, GRANISETRON AND PALONOSETRON IN HIGH-RISK PATIENTS UNDERGOING ABDOMINAL HYSTERECTOMY UNDER GENERAL ANAESTHESIA

    Directory of Open Access Journals (Sweden)

    Rakesh Kumar

    2016-03-01

    Full Text Available BACKGROUND Postoperative nausea and vomiting is (PONV a very distressing complication and preventive measures are justified when the risk of PONV is very high. Ondansetron is the first 5-HT3 antagonist used alone or in combination for prophylaxis of PONV due to its lower cost. Granisetron and palonosetron are recently introduced 5-HT3 antagonists with greater affinity for 5-HT3 receptor and having longer half-life. Aim of the present study is to compare the antiemetic efficacy of ondansetron, granisetron and palonosetron in high-risk patients undergoing abdominal hysterectomy under general anaesthesia. METHODS After obtaining Institutional Ethical Committee approval and written informed consent from all the participants, 150 patients of ASA grade I & II, aged between 20-50 years and weight between 30-60 kg undergoing abdominal hysterectomy under general anaesthesia were assigned randomly in to three groups of 50 patients each using random number table receiving either ondansetron 4 mg (Group O or granisetron 2 mg (Group G or palonosetron 0.75 mg (Group P intravenously just before the induction of anaesthesia. Incidence and severity of nausea and frequency of retching and vomiting were recorded in each group at the end of 2-hour and then at 24-hour and 48-hour intervals. RESULTS The incidence of nausea during first two hours postoperatively was found to be 14(28% in Group O, which was found to be significantly higher than 6(12% in group G and 4(8% in group P (p value = 0.016. The incidence of vomiting was found to be 6(12% in group O, which was found to be significantly higher than 2(4% in both group G and group P (p value = 0.018. Number of complete responders was significantly higher in Group P and group G as compared to group O. Number of patients requiring rescue antiemetic treatment was significantly high in group O{10(20%} as compared to 3(6% in both the group G and group P. CONCLUSIONS Newly introduced 5-HT3 antagonists, granisetron and

  3. High-Z plasma facing components in fusion devices: boundary conditions and operational experiences

    Science.gov (United States)

    Neu, R.

    2006-04-01

    In present day fusion devices optimization of the performance and experimental freedom motivates the use of low-Z plasma facing materials (PFMs). However, in a future fusion reactor, for economic reasons, a sufficient lifetime of the first wall components is essential. Additionally, tritium retention has to be small to meet safety requirements. Tungsten appears to be the most realistic material choice for reactor plasma facing components (PFCs) because it exhibits the lowest erosion. But besides this there are a lot of criteria which have to be fulfilled simultaneously in a reactor. Results from present day devices and from laboratory experiments confirm the advantages of high-Z PFMs but also point to operational restrictions, when using them as PFCs. These are associated with the central impurity concentration, which is determined by the sputtering yield, the penetration of the impurities and their transport within the confined plasma. The restrictions could exclude successful operation of a reactor, but concomitantly there exist remedies to ameliorate their impact. Obviously some price has to be paid in terms of reduced performance but lacking of materials or concepts which could substitute high-Z PFCs, emphasis has to be put on the development and optimization of reactor-relevant scenarios which incorporate the experiences and measures.

  4. High-Z plasma facing components in fusion devices: boundary conditions and operational experiences

    International Nuclear Information System (INIS)

    Neu, R.

    2006-01-01

    In present day fusion devices optimization of the performance and experimental freedom motivates the use of low-Z plasma facing materials (PFMs). However, in a future fusion reactor, for economic reasons, a sufficient lifetime of the first wall components is essential. Additionally, tritium retention has to be small to meet safety requirements. Tungsten appears to be the most realistic material choice for reactor plasma facing components (PFCs) because it exhibits the lowest erosion. But besides this there are a lot of criteria which have to be fulfilled simultaneously in a reactor. Results from present day devices and from laboratory experiments confirm the advantages of high-Z PFMs but also point to operational restrictions, when using them as PFCs. These are associated with the central impurity concentration, which is determined by the sputtering yield, the penetration of the impurities and their transport within the confined plasma. The restrictions could exclude successful operation of a reactor, but concomitantly there exist remedies to ameliorate their impact. Obviously some price has to be paid in terms of reduced performance but lacking of materials or concepts which could substitute high-Z PFCs, emphasis has to be put on the development and optimization of reactor-relevant scenarios which incorporate the experiences and measures

  5. High risk of graft failure in patients with anti-HLA antibodies undergoing haploidentical stem-cell transplantation.

    Science.gov (United States)

    Ciurea, Stefan O; de Lima, Marcos; Cano, Pedro; Korbling, Martin; Giralt, Sergio; Shpall, Elizabeth J; Wang, Xuemei; Thall, Peter F; Champlin, Richard E; Fernandez-Vina, Marcelo

    2009-10-27

    BACKGROUND.: Although donor-specific anti-human leukocyte antigen (HLA) antibodies (DSA) have been implicated in graft rejection in solid organ transplantation, their role in hematopoietic stem-cell transplantation remains unclear. METHODS.: To address the hypothesis that the presence of DSA contributes to the development graft failure, we tested 24 consecutive patients for the presence of anti-HLA antibodies determined by a sensitive and specific solid-phase/single-antigen assay. The study included a total of 28 haploidentical transplants, each with 2 to 5 HLA allele mismatches, at a single institution, from September 2005 to August 2008. RESULTS.: DSA were detected in five patients (21%). Three of four (75%) patients with DSA before the first transplant failed to engraft, compared with 1 of 20 (5%) without DSA (P=0.008). All four patients who experienced primary graft failure had second haploidentical transplants. One patient developed a second graft failure with persistent high DSA levels, whereas three engrafted, two of them in the absence of DSA. No other known factors that could negatively influence engraftment were associated with the development of graft failure in these patients. CONCLUSIONS.: These results suggest that donor-specific anti-HLA antibodies are associated with a high rate of graft rejection in patients undergoing haploidentical stem-cell transplantation. Anti-HLA sensitization should be evaluated routinely in hematopoietic stem-cell transplantation with HLA mismatched donors.

  6. Predictors of seizure occurrence in children undergoing pre-surgical monitoring.

    Science.gov (United States)

    Harini, Chellamani; Singh, Kanwaljit; Takeoka, Masanori; Parulkar, Isha; Bergin, Ann Marie; Loddenkemper, Tobias; Kothare, Sanjeev V

    2013-10-01

    Long-Term-Monitoring (LTM) is a valuable tool for seizure localization/lateralization among children with refractory-epilepsy undergoing pre-surgical-monitoring. The aim of this study was to examine the factors predicting occurrence of single/multiple seizures in children undergoing pre-surgical monitoring in the LTM unit. Chart review was done on 95 consecutive admissions on 92 children (40 females) admitted to the LTM-unit for pre-surgical workup. Relationship between occurrence of multiple (≥ 3) seizures and factors such as home seizure-frequency, demographics, MRI-lesions/seizure-type and localization/AED usage/neurological-exam/epilepsy-duration was evaluated by logistic-regression and survival-analysis. Home seizure-frequency was further categorized into low (up-to 1/month), medium (up-to 1/week) and high (>1/week) and relationship of these categories to the occurrence of multiple seizures was evaluated. Mean length of stay was 5.24 days in all 3 groups. Home seizure frequency was the only factor predicting the occurrence of single/multiple seizures in children undergoing presurgical workup. Other factors (age/sex/MRI-lesions/seizure-type and localization/AED-usage/neurological-exam/epilepsy-duration) did not affect occurrence of single/multiple seizures or time-to-occurrence of first/second seizure. Analysis of the home-seizure frequency categories revealed that 98% admissions in high-frequency, 94% in the medium, and 77% in low-frequency group had at-least 1 seizure recorded during the monitoring. Odds of first-seizure increased in high vs. low-frequency group (p=0.01). Eighty-nine percent admissions in high-frequency, 78% in medium frequency, versus 50% in low-frequency group had ≥ 3 seizures. The odds of having ≥ 3 seizures increased in high-frequency (p=0.0005) and in medium-frequency (p=0.007), compared to low-frequency group. Mean time-to-first-seizure was 2.7 days in low-frequency, 2.1 days in medium, and 2 days in high-frequency group. Time

  7. Stroke treatment academic industry roundtable: research priorities in the assessment of neurothrombectomy devices.

    Science.gov (United States)

    Saver, Jeffrey L; Jovin, Tudor G; Smith, Wade S; Albers, Gregory W; Baron, Jean-Claude; Boltze, Johannes; Broderick, Joseph P; Davis, Lisa A; Demchuk, Andrew M; DeSena, Salvatore; Fiehler, Jens; Gorelick, Philip B; Hacke, Werner; Holt, Bill; Jahan, Reza; Jing, Hui; Khatri, Pooja; Kidwell, Chelsea S; Lees, Kennedy R; Lev, Michael H; Liebeskind, David S; Luby, Marie; Lyden, Patrick; Megerian, J Thomas; Mocco, J; Muir, Keith W; Rowley, Howard A; Ruedy, Richard M; Savitz, Sean I; Sipelis, Vitas J; Shimp, Samuel K; Wechsler, Lawrence R; Wintermark, Max; Wu, Ona; Yavagal, Dileep R; Yoo, Albert J

    2013-12-01

    The goal of the Stroke Treatment Academic Industry Roundtable (STAIR) meetings is to advance the development of stroke therapies. At STAIR VIII, consensus recommendations were developed for clinical trial strategies to demonstrate the benefit of endovascular reperfusion therapies for acute ischemic stroke. Prospects for success with forthcoming endovascular trials are robust, because new neurothrombectomy devices have superior reperfusion efficacy compared with earlier-generation interventions. Specific recommendations are provided for trial designs in 3 populations: (1) patients undergoing intravenous fibrinolysis, (2) early patients ineligible for or having failed intravenous fibrinolysis, and (3) wake-up and other late-presenting patients. Among intravenous fibrinolysis-eligible patients, key principles are that CT or MRI confirmation of target arterial occlusions should precede randomization; endovascular intervention should be pursued with the greatest rapidity possible; and combined intravenous and neurothrombectomy therapy is more promising than neurothrombectomy alone. Among patients ineligible for or having failed intravenous fibrinolysis, scientific equipoise was affirmed and the need to randomize all eligible patients emphasized. Vessel imaging to confirm occlusion is mandatory, and infarct core and penumbral imaging is desirable in later time windows. Additional STAIR VIII recommendations include approaches to test multiple devices in a single trial, utility weighting of disability end points, and adaptive designs to delineate time and tissue injury thresholds at which benefits from intervention no longer accrue. Endovascular research priorities in acute ischemic stroke are to perform trials testing new, highly effective neuro thrombectomy devices rapidly deployed in patients confirmed to have target vessel occlusions.

  8. Transparent conductors based on microscale/nanoscale materials for high performance devices

    Science.gov (United States)

    Gao, Tongchuan

    Transparent conductors are important as the top electrode for a variety of optoelectronic devices, including solar cells, light-emitting diodes (LEDs), at panel displays, and touch screens. Doped indium tin oxide (ITO) thin films are the predominant transparent conductor material. However, ITO thin films are brittle, making them unsuitable for the emerging flexible devices, and suffer from high material and processing cost. In my thesis, we developed a variety of transparent conductors toward a performance comparable with or superior to ITO thin films, with lower cost and potential for scalable manufacturing. Metal nanomesh (NM), hierarchical graphene/metal microgrid (MG), and hierarchical metal NM/MG materials were investigated. Simulation methods were used as a powerful tool to predict the transparency and sheet resistance of the transparent conductors by solving Maxwell's equations and Poisson's equation. Affordable and scalable fabrication processes were developed thereafter. Transparent conductors with over 90% transparency and less than 10 O/square sheet resistance were successfully fabricated on both rigid and flexible substrates. Durability tests, such as bending, heating and tape tests, were carried out to evaluate the robustness of the samples. Haze factor, which characterizes how blurry a transparent conductor appears, was also studied in-depth using analytical calculation and numerical simulation. We demonstrated a tunable haze factor for metal NM transparent conductors and analyzed the principle for tuning the haze factor. Plasmonic effects, excited by some transparent conductors, can lead to enhanced performance in photovoltaic devices. We systematically studied the effect of incorporating metal NM into ultrathin film silicon solar cells using numerical simulation, with the aid of optimization algorithms to reduce the optimization time. Mechanisms contributing to the enhanced performance were then identified and analyzed. Over 72% enhancement in short

  9. Explosive device of conduit using Ti Ni alloy

    Directory of Open Access Journals (Sweden)

    A. Yu. Kolobov

    2014-01-01

    Full Text Available Presently, materials have been developed which are capable at changing temperate to return significant inelastic deformations, exhibit rubber-like elasticity, convert heat into mechanical work, etc. The aggregate of these effects is usually called the shape memory effect.At present a great number of compounds and alloys with a shape memory effect has been known.These are alloys based on titanium nickelide (TiNi, copper-based alloys (Cu-Al, Cu-Sn, Cu-Al-Ni, Cu-Zn-Si, etc., gold and silver (Ag-Cd, Au-Ag-Cd, Au-Cd-Cu, Au-Zn-Cu, etc., manganese (Mn-Cr, Fe-Cu, Mn-Cu-Ni, Mn-Cu-Zr, Mn-Ni, etc., iron (Fe-Mn, Fe-Ni, Fe-Al, etc., and other compounds.The alloys based on titanium nickelide (nitinol are the most widely used.Alloys with shape memory effect find various applications in engineering and medicine, namely connecting devices, actuators, transformable design, multipurpose medical implants, etc.There is a task of breaking fuel conduit during separating the spacecraft from the rocket in space technology.The paper examines the procedure for design calculation of the separating device of conduit with the use of Ti-Ni alloy. This device can be used instead of the pyro-knives.The device contains two semi-rings from Ti-Ni alloy. In the place of break on the conduit an annular radius groove is made.At a temperature of martensite passage the semi-rings undergo deformation and in the strained state are set in the device. With heating to the temperature of the austenitic passage of bushing macro-deformation the energy stored by the nitinol bushing is great enough to break the conduit on the neck.The procedures of design calculation and response time of device are given.

  10. A Flexible High-Performance Photoimaging Device Based on Bioinspired Hierarchical Multiple-Patterned Plasmonic Nanostructures.

    Science.gov (United States)

    Lee, Yoon Ho; Lee, Tae Kyung; Kim, Hongki; Song, Inho; Lee, Jiwon; Kang, Saewon; Ko, Hyunhyub; Kwak, Sang Kyu; Oh, Joon Hak

    2018-03-01

    In insect eyes, ommatidia with hierarchical structured cornea play a critical role in amplifying and transferring visual signals to the brain through optic nerves, enabling the perception of various visual signals. Here, inspired by the structure and functions of insect ommatidia, a flexible photoimaging device is reported that can simultaneously detect and record incoming photonic signals by vertically stacking an organic photodiode and resistive memory device. A single-layered, hierarchical multiple-patterned back reflector that can exhibit various plasmonic effects is incorporated into the organic photodiode. The multiple-patterned flexible organic photodiodes exhibit greatly enhanced photoresponsivity due to the increased light absorption in comparison with the flat systems. Moreover, the flexible photoimaging device shows a well-resolved spatiotemporal mapping of optical signals with excellent operational and mechanical stabilities at low driving voltages below half of the flat systems. Theoretical calculation and scanning near-field optical microscopy analyses clearly reveal that multiple-patterned electrodes have much stronger surface plasmon coupling than flat and single-patterned systems. The developed methodology provides a versatile and effective route for realizing high-performance optoelectronic and photonic systems. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  11. A quality assurance program for ancillary high technology devices on a dual-energy accelerator

    International Nuclear Information System (INIS)

    Klein, Eric E.; Low, Daniel A.; Maag, Derek; Purdy, James A.

    1996-01-01

    Our facility has added high-technology ancillary devices to our dual-energy linear accelerator. After commissioning and acceptance testing of dual asymmetric jaws, dynamic wedge, portal imaging, and multileaf collimation (MLC), quality assurance programs were instituted. The programs were designed to be both periodic and patient specific when required. In addition, when dosimetric aspects were affected by these technologies, additional quality assurance checks were added. Positional accuracy checks (light and radiation) are done for both asymmetric jaws and MLC. Each patient MLC field is checked against the original simulation or digitally reconstructed radiographs. Off-axis factors and output checks are performed for asymmetric fields. Dynamic wedge transmission factors and profiles are checked periodically, and a patient diode check is performed for every new dynamic wedge portal. On-line imaging checks encompass safety checks along with periodic measurement of contrast and spatial resolution. The most important quality assurance activity is the annual review of proper operation and procedures for each device. Our programs have been successful in avoiding patient-related errors or device malfunctions. The programs are a team effort involving physicists, maintenance engineers, and therapists

  12. Glaucoma Drainage Device Erosion Following Ptosis Surgery.

    Science.gov (United States)

    Bae, Steven S; Campbell, Robert J

    2017-09-01

    To highlight the potential risk of glaucoma drainage device erosion following ptosis surgery. Case report. A 71-year-old man underwent uncomplicated superotemporal Ahmed glaucoma valve implantation in the left eye in 2008. Approximately 8 years later, the patient underwent bilateral ptosis repair, which successfully raised the upper eyelid position. Three months postoperatively, the patient's glaucoma drainage implant tube eroded through the corneal graft tissue and overlying conjunctiva to become exposed. A graft revision surgery was successfully performed with no further complications. Caution and conservative lid elevation may be warranted when performing ptosis repair in patients with a glaucoma drainage implant, and patients with a glaucoma implant undergoing ptosis surgery should be followed closely for signs of tube erosion.

  13. Earthquake proof device for nuclear power plant building

    International Nuclear Information System (INIS)

    Okada, Yasuo.

    1991-01-01

    The structure of the present invention enables three dimensional vibration proof, i.e., in horizontal and vertical directions of a reactor container building. That is, each of the reactor container building and a reactor auxiliary building is adapted as an independent structure. The periphery of the reactor container building is surrounded by the reactor auxiliary building. The reactor auxiliary building is supported against the ground by way of a horizontal vibration proof device. The reactor container building is supported against the ground by way of a three-dimensional vibration proof device that prevents vibrations in both of the horizontal directions, and the vertical directions. The reactor container building is connected to the auxiliary building by way of a vertical vibration proof device. With such a constitution, although the reactor container building is vibration proof against both of the horizontal and the vertical vibrations, the vertical vibration proofness is an extension of inherent vertical vibration period. Accordingly, the head of the building undergoes rocking vibrations. However, since the reactor container building is connected to the reactor auxiliary building, the rocking vibrations are prevented by the reactor auxiliary building. As a result, safety upon occurrence of an earthquakes can be ensured. (I.S.)

  14. A design handbook for phase change thermal control and energy storage devices. [selected paraffins

    Science.gov (United States)

    Humphries, W. R.; Griggs, E. I.

    1977-01-01

    Comprehensive survey is given of the thermal aspects of phase change material devices. Fundamental mechanisms of heat transfer within the phase change device are discussed. Performance in zero-g and one-g fields are examined as it relates to such a device. Computer models for phase change materials, with metal fillers, undergoing conductive and convective processes are detailed. Using these models, extensive parametric data are presented for a hypothetical configuration with a rectangular phase change housing, using straight fins as the filler, and paraffin as the phase change material. These data are generated over a range of realistic sizes, material properties, and thermal boundary conditions. A number of illustrative examples are given to demonstrate use of the parametric data. Also, a complete listing of phase change material property data are reproduced herein as an aid to the reader.

  15. Device for the collimation of a high-energy beam, in particular a X-ray beam

    International Nuclear Information System (INIS)

    Peyser, L.F.

    1976-01-01

    The design of apertures made of radiation-absorbing material intended for limiting an aperture for a radiation beam of high energy, in particular an X-ray beam is claimed. The apertures are shaped as trapezoids, are held movably, and are adjustable by means of a control device. (UWI) [de

  16. Understanding and controlling chromaticity shift in LED devices

    Energy Technology Data Exchange (ETDEWEB)

    Davis, Lynn; Mills, Karmann; Lamvik, Michael; Perkins, Curtis; Bobashev, Georgiy; Young, Joseph; Yaga, Robert; Johnson, Cortina

    2017-05-30

    Chromaticity shift in light-emitting diode (LED) devices arises from multiple mechanisms, and at least five different chromaticity shift modes (CSMs) have been identified to date. This paper focuses on the impacts of irreversible phosphor degradation as a cause of chromaticity shifts in LED devices. The nitride phosphors used to produce warm white LEDs are especially vulnerable to degradation due to thermal and chemical effects such as reactions with oxygen and water. As a result, LED devices utilizing these phosphors were found to undergo either a green shift or, less commonly, a red shift depending on the phosphor mix in the LED devices. These types of chromaticity shifts are classified as CSM-2 (green shift) and CSM-5 (red shift). This paper provides an overview of the kinetic processes responsible for green and red chromaticity shifts along with examples from accelerated stress testing of 6” downlights. Both CSMs appear to proceed through analogous mechanisms that are initiated at the surface of the phosphor. A green shift is produced by the surface oxidation of the nitride phosphor that changes the emission profile to lower wavelengths. As the surface oxidation reaction proceeds, reactant limitations slow the rate and bulk oxidation processes become more prevalent. We found that a red chromaticity shift arises from quenching of the green phosphor, also possibly due to surface reactions of oxygen, which shift the emission chromaticity in the red direction. In conclusion, we discuss the implications of these findings on projecting chromaticity.

  17. Ternary Au/ZnO/rGO nanocomposites electrodes for high performance electrochemical storage devices

    Science.gov (United States)

    Chaudhary, Manchal; Doong, Ruey-an; Kumar, Nagesh; Tseng, Tseung Yuen

    2017-10-01

    The combination of metal and metal oxide nanoparticles with reduced graphene oxides (rGO) is an active electrode material for electrochemical storage devices. Herein, we have, for the first time, reported the fabrication of ternary Au/ZnO/rGO nanocomposites by using a rapid and environmentally friendly microwave-assisted hydrothermal method for high performance supercapacitor applications. The ZnO/rGO provides excellent electrical conductivity and good macro/mesopore structures, which can facilitate the rapid electrons and ions transport. The Au nanoparticles with particle sizes of 7-12 nm are homogeneously distributed onto the ZnO/rGO surface to enhance the electrochemical performance by retaining the capacitance at high current density. The Au/ZnO/rGO nanocomposites, prepared with the optimized rGO amount of 100 mg exhibit a high specific capacitance of 875 and 424 F g-1 at current densities of 1 and 20 A g-1, respectively, in 2 M KOH. In addition, the energy and power densities of ternary Au/ZnO/rGO can be up to 17.6-36.5 Wh kg-1 and 0.27-5.42 kW kg-1, respectively. Results obtained in this study clearly demonstrate the excellence of ternary Au/ZnO/rGO nanocomposites as the active electrode materials for electrochemical pseudocapacitor performance and can open an avenue to fabricate metal/metal oxide/rGO nanocomposites for electrochemical storage devices with both high energy and power densities.

  18. High voltage-derived enhancement of electric conduction in nanogap devices for detection of prostate-specific antigen

    Science.gov (United States)

    Park, Hyung Ju; Chi, Young Shik; Choi, Insung S.; Yun, Wan Soo

    2010-07-01

    We report a simple method of enhancing electric conductance in nanogap devices without any additional treatments, such as silver-enhancing process. The low electric conductance after selective immobilization of biofunctionalized gold nanoparticles in the gap region was greatly enhanced by repeated I-V scans at relatively high voltage ranges of -5 to 5 V, which was attributed to the formation of a new conduction pathway across the gap. The higher conduction state of the nanogap device showed a very stable I-V curve, which was used as an excellent measure of the existence of prostate-specific antigen.

  19. High performance electrical, magnetic, electromagnetic and electrooptical devices enabled by three dimensionally ordered nanodots and nanorods

    Science.gov (United States)

    Goyal, Amit , Kang; Sukill, [Knoxville, TN

    2012-02-21

    Novel articles and methods to fabricate same with self-assembled nanodots and/or nanorods of a single or multicomponent material within another single or multicomponent material for use in electrical, electronic, magnetic, electromagnetic and electrooptical devices is disclosed. Self-assembled nanodots and/or nanorods are ordered arrays wherein ordering occurs due to strain minimization during growth of the materials. A simple method to accomplish this when depositing in-situ films is also disclosed. Device applications of resulting materials are in areas of superconductivity, photovoltaics, ferroelectrics, magnetoresistance, high density storage, solid state lighting, non-volatile memory, photoluminescence, thermoelectrics and in quantum dot lasers.

  20. Alfaxalone or ketamine-medetomidine in cats undergoing ovariohysterectomy: a comparison of intra-operative parameters and post-operative pain.

    Science.gov (United States)

    Kalchofner Guerrero, Karin S; Reichler, Iris M; Schwarz, Andrea; Jud, Rahel S; Hässig, Michael; Bettschart-Wolfensberger, Regula

    2014-11-01

    To compare post-operative pain in cats after alfaxalone or ketamine- medetomidine anaesthesia for ovariohysterectomy (OHE) and physiologic parameters during and after surgery. Prospective 'blinded' randomized clinical study. Twenty-one healthy cats. Cats were assigned randomly into two groups: Group A, anaesthesia was induced and maintained with alfaxalone [5 mg kg(-1) intravenously (IV) followed by boli (2 mg kg(-1) IV); Group MK, induction with ketamine (5 mg kg(-1) IV) after medetomidine (30 μg kg(-1) intramuscularly (IM)], and maintenance with ketamine (2 mg kg(-1) IV). Meloxicam (0.2 mg kg(-1) IV) was administered after surgery. Basic physiological data were collected. At time T = -2, 0, 0.5, 1, 2, 4, 6, 8, 12, 16, 20, and 24 hours post-operatively pain was assessed by three methods, a composite pain scale (CPS; 0-24 points), a visual analogue scale (VAS 0-100 mm), and a mechanical wound threshold (MWT) device. Butorphanol (0.2 mg kg(-1) IM) was administered if CPS was scored ≥13. Data were analyzed using a general linear model, Kruskal-Wallis analyses, Bonferroni-Dunn test, unpaired t-test and Fisher's exact test as relevant. Significance was set at p ketamine-medetomidine was found to provide better post-surgical analgesia than alfaxalone in cats undergoing OHE; however, primary hyperalgesia developed in both groups. Alfaxalone is suitable for induction and maintenance of anaesthesia in cats undergoing OHE, but administration of additional sedative and analgesic drugs is highly recommended. © 2014 Association of Veterinary Anaesthetists and the American College of Veterinary Anesthesia and Analgesia.

  1. Oral lesions in HIV+/AIDS adolescents perinatally infected undergoing HAART.

    Science.gov (United States)

    Gaitán-Cepeda, Luis-Alberto; Domínguez-Sánchez, Anitza; Pavía-Ruz, Noris; Muñoz-Hernández, Rocío; Verdugo-Díaz, Roberto; Valles-Medina, Ana-María; Meráz-Acosta, Héctor

    2010-07-01

    To assess the prevalence of the oral lesions related to HIV-infection (HIV-OL) in HIV+/AIDS adolescents (=13 years old), and the differences with HIV+/AIDS children (=3 - 0.05). Oral candidiasis was the most prevalent oral lesion in both groups. Association (p<0.05) of a high prevalence of HIV-OL and oral candidiasis with a high viral load was observed in both study groups. Adolescents perinatally HIV-infected have a high prevalence of HIV-OL. Oral Candidiasis still is the most frequent oral opportunistic infection. Oral lesions could have association to viral failure in HIV+/AIDS adolescents undergoing HAART.

  2. Continuous and high-level in vivo delivery of endostatin from recombinant cells encapsulated in TheraCyte immunoisolation devices.

    Science.gov (United States)

    Malavasi, N V; Rodrigues, D B; Chammas, R; Chura-Chambi, R M; Barbuto, J A M; Balduino, K; Nonogaki, S; Morganti, L

    2010-01-01

    Endostatin (ES) is a potent inhibitor of angiogenesis and tumor growth. Continuous ES delivery of ES improves the efficacy and potency of the antitumoral therapy. The TheraCyte system is a polytetrafluoroethylene (PTFE) semipermeable membrane macroencapsulation system for implantation of genetically engineered cells specially designed for the in vivo delivery of therapeutic proteins, such as ES, which circumvents the problem of limited half-life and variation in circulating levels. In order to enable neovascularization at the tissues adjacent to the devices prior to ES secretion by the cells inside them, we designed a scheme in which empty TheraCyte devices were preimplanted SC into immunodeficient mice. Only after healing (17 days later) were Chinese hamster ovary cells expressing ES injected into the preimplanted devices. In another model for device implantation, the cells expressing ES where loaded into the immunoisolation devices prior to implantation into the animals, and the TheraCyte were then immediately implanted SC into the mice. Throughout the 2-month study, constant high ES levels of up to 3.7 microg/ml were detected in the plasma of the mice preimplanted with the devices, while lower but also constant levels of ES (up to 2.1 microg/ml plasma) were detected in the mice that had received devices preloaded with the ES-expressing cells. Immunohistochemistry using anti-ES antibody showed reaction within the device and outside it, demonstrating that ES, secreted by the confined recombinant cells, permeated through the membrane and reached the surrounding tissues.

  3. The influence of health care policies and health care system distrust on willingness to undergo genetic testing.

    Science.gov (United States)

    Armstrong, Katrina; Putt, Mary; Halbert, Chanita Hughes; Grande, David; Schwartz, Jerome Sanford; Liao, Kaijun; Marcus, Noora; Demeter, Mirar Bristol; Shea, Judy

    2012-05-01

    As the potential role of genetic testing in disease prevention and management grows, so does concern about differences in uptake of genetic testing across social and racial groups. Characteristics of how genetic tests are delivered may influence willingness to undergo testing and, if they affect population subgroups differently, alter disparities in testing. Conjoint analysis study of the effect of 3 characteristics of genetic test delivery (ie, attributes) on willingness to undergo genetic testing for cancer risk. Data were collected using a random digit dialing survey of 128 African American and 209 white individuals living in the United States. Measures included conjoint scenarios, the Revised Health Care System Distrust Scale (including the values and competence subscales), health insurance coverage, and sociodemographic characteristics. The 3 attributes studied were disclosure of test results to the health insurer, provision of the test by a specialist or primary care doctor, and race-specific or race-neutral marketing. In adjusted analyses, disclosure of test results to insurers, having to get the test from a specialist, and race-specific marketing were all inversely associated with willingness to undergo the genetic test, with the greatest effect for the disclosure attribute. Racial differences in willingness to undergo testing were not statistically significant (P=0.07) and the effect of the attributes on willingness to undergo testing did not vary by patient race. However, the decrease in willingness to undergo testing with insurance disclosure was greater among individuals with high values distrust (P=0.03), and the decrease in willingness to undergo testing from specialist access was smaller among individuals with high competence distrust (P=0.03). Several potentially modifiable characteristics of how genetic tests are delivered are associated with willingness to undergo testing. The effect of 2 of these characteristics vary according to the level of

  4. Highly efficient phosphorescent blue and white organic light-emitting devices with simplified architectures

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Chih-Hao, E-mail: chc@saturn.yzu.edu.tw [Department of Photonics Engineering, Yuan Ze University, Chung-Li, Taiwan 32003 (China); Ding, Yong-Shung; Hsieh, Po-Wei; Chang, Chien-Ping; Lin, Wei-Chieh [Department of Photonics Engineering, Yuan Ze University, Chung-Li, Taiwan 32003 (China); Chang, Hsin-Hua, E-mail: hhua3@mail.vnu.edu.tw [Department of Electro-Optical Engineering, Vanung University, Chung-Li, Taiwan 32061 (China)

    2011-09-01

    Blue phosphorescent organic light-emitting devices (PhOLEDs) with quantum efficiency close to the theoretical maximum were achieved by utilizing a double-layer architecture. Two wide-triplet-gap materials, 1,3-bis(9-carbazolyl)benzene and 1,3,5-tri[(3-pyridyl)-phen-3-yl]benzene, were employed in the emitting and electron-transport layers respectively. The opposite carrier-transport characteristics of these two materials were leveraged to define the exciton formation zone and thus increase the probability of recombination. The efficiency at practical luminance (100 cd/m{sup 2}) was as high as 20.8%, 47.7 cd/A and 31.2 lm/W, respectively. Furthermore, based on the design concept of this simplified architecture, efficient warmish-white PhOLEDs were developed. Such two-component white organic light-emitting devices exhibited rather stable colors over a wide brightness range and yielded electroluminescence efficiencies of 15.3%, 33.3 cd/A, and 22.7 lm/W in the forward directions.

  5. Highly efficient phosphorescent blue and white organic light-emitting devices with simplified architectures

    International Nuclear Information System (INIS)

    Chang, Chih-Hao; Ding, Yong-Shung; Hsieh, Po-Wei; Chang, Chien-Ping; Lin, Wei-Chieh; Chang, Hsin-Hua

    2011-01-01

    Blue phosphorescent organic light-emitting devices (PhOLEDs) with quantum efficiency close to the theoretical maximum were achieved by utilizing a double-layer architecture. Two wide-triplet-gap materials, 1,3-bis(9-carbazolyl)benzene and 1,3,5-tri[(3-pyridyl)-phen-3-yl]benzene, were employed in the emitting and electron-transport layers respectively. The opposite carrier-transport characteristics of these two materials were leveraged to define the exciton formation zone and thus increase the probability of recombination. The efficiency at practical luminance (100 cd/m 2 ) was as high as 20.8%, 47.7 cd/A and 31.2 lm/W, respectively. Furthermore, based on the design concept of this simplified architecture, efficient warmish-white PhOLEDs were developed. Such two-component white organic light-emitting devices exhibited rather stable colors over a wide brightness range and yielded electroluminescence efficiencies of 15.3%, 33.3 cd/A, and 22.7 lm/W in the forward directions.

  6. Magnetostrictive device for high-temperature sound and vibration measurement in nuclear power stations

    International Nuclear Information System (INIS)

    Hans, R.; Podgorski, J.

    1977-01-01

    The demands on the monitoring systems in nuclear power stations are increasing continuously, not only because of more stringent safety requirements but also for reasons of plant availability and thus economic efficiency. The noise and vibration measurements which therefore have to be taken make it necessary to provide measuring devices with a high degree of efficiency, adequate sensitivity and resistance to high temperatures, radiation and corrosion. Probes using the magnetostrictive effect, whereby a ferromagnetic core changes its length in a magnetic field - a phenomenon which has been known for approximately fifty years - fulfill all the conditions for application in nuclear power stations. (orig.) [de

  7. Device for detecting imminent failure of high-dielectric stress capacitors. [Patent application

    Science.gov (United States)

    McDuff, G.G.

    1980-11-05

    A device is described for detecting imminent failure of a high-dielectric stress capacitor utilizing circuitry for detecting pulse width variations and pulse magnitude variations. Inexpensive microprocessor circuitry is utilized to make numerical calculations of digital data supplied by detection circuitry for comparison of pulse width data and magnitude data to determine if preselected ranges have been exceeded, thereby indicating imminent failure of a capacitor. Detection circuitry may be incorporated in transmission lines, pulse power circuitry, including laser pulse circuitry or any circuitry where capacitors or capacitor banks are utilized.

  8. Proposed high speed pellet injection system 'HIPEL' for Large Helical Device

    International Nuclear Information System (INIS)

    Sudo, S.; Kanno, M.; Kaneko, H.; Saka, S.; Shirai, T.; Baba, T.

    1993-11-01

    From the results of the simulation study including pellet ablation and 1-D transport code, it is found that a high speed pellet injector with pellet velocity of more than 3 km/s is necessary for the penetration of the pellet with diameter of 3 mm into the core region under the expected plasma condition of Large Helical Device (LHD) of heliotron/stellarator type with superconducting coils at NIFS in Japan. Therefore, a two stage pellet injector was constructed and tested successfully in order to obtain the pellet velocity range of 3 km/s. Based upon the above results, a high speed flexible multiple-pellet injection system 'HIPEL' for LHD is proposed. HIPEL consists of independent (1) 10 two-stage gun barrels and (2) 10 single-stage gun barrels. It has multi purposes such as refueling and flexible density profile control, diagnostics and the other functions. (author)

  9. Optimum DMOS cell doping profiles for high-voltage discrete and integrated device technologies

    Science.gov (United States)

    Shenai, Krishna

    1992-05-01

    It is shown that the implantation and activation sequences of B and As result in significant variations in the contact resistance and p-base sheet resistance beneath the n+-source diffusion of a DMOSFET cell. For identical process parameters, the contact resistance of As-doped n+ silicon was significantly improved when high-dose B was implanted due to higher As surface concentration. The SUPREM III process modeling results were found to be in qualitative agreement with the measured spreading resistance profiles and the discrepancies could be attributed to larger high-temperature diffusion constants used in SUPREM III and the coupled As-B diffusion/activation effects that are not accounted for in process modeling. The experimental results are discussed within the framework of fabricating high-performance DMOSFET cells and CMOS high-voltage devices on the same chip for discrete and smart-power applications.

  10. [Design of SCM inoculation device].

    Science.gov (United States)

    Qian, Mingli; Xie, Haiyuan

    2014-01-01

    The first step of bacilli culture is inoculation bacteria on culture medium. Designing a device to increase efficiency of inoculation is significative. The new device is controlled by SCM. The stepper motor can drive the culture medium rotating, accelerating, decelerating, overturn and suspending. The device is high practicability and efficient, let inoculation easy for operator.

  11. The evaluation for usefulness of the custom made immobilization device for the anteroperitoneal resection patients with rectal cancer

    International Nuclear Information System (INIS)

    Yang, Oh Nam; Lee, Woo Seok; Hong, Tae Kyun; Jo, Young Pih; Yun, Hwa Ryong; Kim, Jung Man

    2003-01-01

    Patient immobilization is essential factor for successful radiation therapy and major problem is reproducibility to maintain patient position during total radiation therapy period. Purpose of this study is evaluation for usefulness of the custom made immobilization device for the anteroperitoneal resection patients with rectal cancer. The object of this study were patients who underwent anteroperitoneal resection and undergo radiation therapy at present with rectal cancer. We made immobilization device for patient individually and analyzed its set up reproducibility, patient position deviation and errors. There was 5 mm-10 mm deviation in patient position without individual immobilization device, but we improved the deviation within few mm limitation with individual immobilization device. Custom made immobilization device was very helpful for anteroperitoneal resection patient with rectal cancer. We improved the patient position deviation within few mm limitation, shorten the set up time and we could give the comfort to patients.

  12. Implantation of a HeartMate II left ventricular assist device via left thoracotomy.

    Science.gov (United States)

    Cho, Yang Hyun; Deo, Salil V; Schirger, John A; Pereira, Naveen L; Stulak, John M; Park, Soon J

    2012-11-01

    Left thoracotomy was used as an approach for the implantation of pulsatile ventricular assist devices. Avoiding the standard approach of median sternotomy is attractive in patients undergoing complicated redo cardiac surgery, especially with prior mediastinal radiation. We report a case of the use of left thoracotomy for the implantation of the HeartMate II axial-flow pump. Copyright © 2012 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  13. A randomised controlled study of standard versus accelerated deflation of the Terumo radial band haemostasis device after transradial diagnostic cardiac catheterisation

    NARCIS (Netherlands)

    Deuling, J. Han; Vermeulen, Robert P.; van den Heuvel, A. F. M.; Schurer, Remco A. J.; van der Harst, Pim

    2017-01-01

    Background: Radial access is the preferential access route in patients undergoing diagnostic coronary angiography. We hypothesised that we could reduce hospital stay and improve patient comfort by accelerated deflation of the radial compression device (Terumo radial band). Aims: The aim of this

  14. High-frequency Lamb wave device composed of MEMS structure using LiNbO3 thin film and air gap.

    Science.gov (United States)

    Kadota, Michio; Ogami, Takashi; Yamamoto, Kansho; Tochishita, Hikari; Negoro, Yasuhiro

    2010-11-01

    High-frequency devices operating at 3 GHz or higher are required, for instance, for future 4th generation mobile phone systems in Japan. Using a substrate with a high acoustic velocity is one method to realize a high-frequency acoustic or elastic device. A Lamb wave has a high velocity when the substrate thickness is thin. To realize a high-frequency device operating at 3 GHz or higher using a Lamb wave, a very thin (less than 0.5 μm thick) single-crystal plate must be used. It is difficult to fabricate such a very thin single crystal plate. The authors have attempted to use a c-axis orientated epitaxial LiNbO(3) thin film deposited by a chemical vapor deposition system (CVD) instead of using a thin LiNbO(3) single crystal plate. Lamb wave resonators composed of a interdigital transducer (IDT)/the LiNbO(3) film/air gap/base substrate structure like micro-electromechanical system (MEMS) transducers were fabricated. These resonators have shown a high frequency of 4.5 and 6.3 GHz, which correspond to very high acoustic velocities of 14,000 and 12,500 m/s, respectively, have excellent characteristics such as a ratio of resonant and antiresonant impedance of 52 and 38 dB and a wide band of 7.2% and 3.7%, respectively, and do not have spurious responses caused by the 0th modes of shear horizontal (SH(0)) and symmetric (S(0)) modes.

  15. Atmospheric Pressure Chemical Vapor Deposition of CdTe for High-Efficiency Thin-Film PV Devices; Annual Report, 26 January 1998-25 January 1999

    Energy Technology Data Exchange (ETDEWEB)

    Meyers, P. V. [ITN Energy Systems, Wheat Ridge, Colorado (US); Kee, R.; Wolden, C.; Raja, L.; Kaydanov, V.; Ohno, T.; Collins, R.; Aire, M.; Kestner, J. [Colorado School of Mines, Golden, Colorado (US); Fahrenbruch, A. [ALF, Inc., Stanford, California (US)

    1999-09-30

    ITN's 3-year project, titled ''Atmospheric Pressure Chemical Vapor Deposition (APCVD) of CdTe for High-Efficiency Thin-Film Photovoltaic (PV) Devices,'' has the overall objectives of improving thin-film CdTe PV manufacturing technology and increasing CdTe PV device power conversion efficiency. CdTe deposition by APCVD employs the same reaction chemistry as has been used to deposit 16%-efficient CdTe PV films, i.e., close-spaced sublimation, but employs forced convection rather than diffusion as a mechanism of mass transport. Tasks of the APCVD program center on demonstrating APCVD of CdTe films, discovering fundamental mass-transport parameters, applying established engineering principles to the deposition of CdTe films, and verifying reactor design principles that could be used to design high-throughput, high-yield manufacturing equipment. Additional tasks relate to improved device measurement and characterization procedures that can lead to a more fundamental understanding of CdTe PV device operation, and ultimately, to higher device conversion efficiency and greater stability. Specifically, under the APCVD program, device analysis goes beyond conventional one-dimensional device characterization and analysis toward two-dimension measurements and modeling. Accomplishments of the first year of the APCVD subcontract include: selection of the Stagnant Flow Reactor design concept for the APCVD reactor, development of a detailed reactor design, performance of detailed numerical calculations simulating reactor performance, fabrication and installation of an APCVD reactor, performance of dry runs to verify reactor performance, performance of one-dimensional modeling of CdTe PV device performance, and development of a detailed plan for quantification of grain-boundary effects in polycrystalline CdTe devices.

  16. Design of a 4D emittance measurement device for high charge state ECR ion sources

    International Nuclear Information System (INIS)

    Zhao Yangyang; Yang Yao; Zhao Hongwei; Sun Liangting; Cao Yun; Wang Yun

    2013-01-01

    For the purpose of on-line beam quality diagnostics and transverse emittance coupling investigation of the ion beams delivered by an Electron Cyclotron Resonance (ECR) ion source, a real-time 4D Pepper Pot type emittance scanner is under development at IMP (Institute of Moden Physics, Chinese Academy of Sciences). The high charge state ECR ion source at IMP could produce CW or pulsed heavy ion beam intensities in the range of 1 eμA∼1 emA with the kinetic energy of 10∼35 keV/q, which needs the design of the Pepper Pot scanner to be optimized accordingly. The Pepper Pot scanner has many features, such as very short response time and wide dynamic working range that the device could be applied. Since intense heavy ion beam bombardment is expected for this device, the structure and the material selection for the device is specially considered during the design, and a feasible solution to analyze the pictures acquired after the data acquisition is also made. (authors)

  17. Predicting blood transfusion in patients undergoing minimally invasive oesophagectomy.

    Science.gov (United States)

    Schneider, Crispin; Boddy, Alex P; Fukuta, Junaid; Groom, William D; Streets, Christopher G

    2014-12-01

    To evaluate predictors of allogenic blood transfusion requirements in patients undergoing minimal invasive oesophagectomy at a tertiary high volume centre for oesophago-gastric surgery. Retrospective analysis of all patients undergoing minimal access oesophagectomy in our department between January 2010 and December 2011. Patients were divided into two groups depending on whether they required a blood transfusion at any time during their index admission. Factors that have been shown to influence perioperative blood transfusion requirements in major surgery were included in the analysis. Binary logistic regression analysis was performed to determine the impact of patient and perioperative characteristics on transfusion requirements during the index admission. A total of 80 patients underwent minimal access oesophagectomy, of which 61 patients had a laparoscopic assisted oesophagectomy and 19 patients had a minimal invasive oesophagectomy. Perioperative blood transfusion was required in 28 patients at any time during hospital admission. On binary logistic regression analysis, a lower preoperative haemoglobin concentration (p blood transfusion requirements. It has been reported that requirement for blood transfusion can affect long-term outcomes in oesophageal cancer resection. Two factors which could be addressed preoperatively; haemoglobin concentration and type of oesophageal resection, may be valuable in predicting blood transfusions in patients undergoing minimally invasive oesophagectomy. Our analysis revealed that preoperative haemoglobin concentration, occurrence of significant complications and type of minimal access oesophagectomy predicted blood transfusion requirements in the patient population examined. Copyright © 2014 Surgical Associates Ltd. Published by Elsevier Ltd. All rights reserved.

  18. Development of an efficient DC-DC SEPIC converter using wide bandgap power devices for high step-up applications

    Science.gov (United States)

    Al-bayati, Ali M. S.; Alharbi, Salah S.; Alharbi, Saleh S.; Matin, Mohammad

    2017-08-01

    A highly efficient high step-up dc-dc converter is the major requirement in the integration of low voltage renewable energy sources, such as photovoltaic panel module and fuel cell stacks, with a load or utility. This paper presents the development of an efficient dc-dc single-ended primary-inductor converter (SEPIC) for high step-up applications. Three SEPIC converters are designed and studied using different combinations of power devices: a combination based on all Si power devices using a Si-MOSFET and a Si-diode and termed as Si/Si, a combination based on a hybrid of Si and SiC power devices using the Si-MOSFET and a SiC-Schottky diode and termed as Si/SiC, and a combination based on all SiC power devices using a SiC-MOSFET and the SiC-Schottky diode and termed as SiC/SiC. The switching behavior of the Si-MOSFET and SiC-MOSFET is characterized and analyzed within the different combinations at the converter level. The effect of the diode type on the converter's overall performance is also discussed. The switching energy losses, total power losses, and the overall performance effciency of the converters are measured and reported under different switching frequencies. Furthermore, the potential of the designed converters to operate efficiently at a wide range of input voltages and output powers is studied. The analysis and results show an outstanding performance efficiency of the designed SiC/SiC based converter under a wide range of operating conditions.

  19. Fiscal 2000 survey report on the survey of trends of quantum beam process technologies for development of high-speed large-capacity digital electronic information devices; 2000 nendo kosoku daiyoryo digital denshi joho device kaihatsu no tame no ryoshi beam process technology no doko chosa hokokusho

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-03-01

    The effort clarifies the tasks and problems of the next-generation WDM (wavelength division multiplexing) device, the tasks and problems of domestic information digital devices, and the characteristics, and matters wanting further development, of quantum beam technologies that are to contribute to the development of the said devices. In concrete terms, quantum process technologies involving the ultralow energy ion beam, gas cluster ion beam, electron beam, laser beam, radiation, and the like, are to be studied and developed as device processes, and the product of the effort will be utilized for accelerating the currently difficult development of the semiconductor laser diode, high-speed photoelectric conversion diode, optical circuit device, and the next-generation plastic liquid crystal display device. That is to say, process technologies for a high-speed undamaged compound semiconductor device, high-precision optical circuit device, and a totally plastic liquid crystal display device will be established, and verified as valid. Furthermore, novel digital devices will be developed. In this research and development work, manufacturing process technologies will also be established, which as practical technologies will clear the rigorous goals that the industry demand for process stability, process yield, process amount, and the like. (NEDO)

  20. Surface micromachined counter-meshing gears discrimination device

    International Nuclear Information System (INIS)

    Polosky, M.A.; Garcia, E.J.; Allen, J.J.

    1998-01-01

    This paper discusses the design, fabrication and testing of a surface micromachined Counter-Meshing Gears (CMG) discrimination device which functions as a mechanically coded lock, A 24 bit code is input to unlock the device. Once unlocked, the device provides a path for an energy or information signal to pass through the device. The device is designed to immediately lock up if any portion of the 24 bit code is incorrect. The motivation for the development of this device is based on occurrences referred to as High Consequence Events, A High Consequence Event is an event where an inadvertent operation of a system could result in the catastrophic loss of life, property, or damage to the environment

  1. Device for measuring high temperature heat conductivity of solids and melts

    International Nuclear Information System (INIS)

    Magomedov, Ya.B.; Gadzhiev, G.G.

    1990-01-01

    A modification of a device for measuring heat conductivity by a compensation method when a thermocouple with gadolinium sulfide being used is suggested. Such a device has less error of measurement (8%), wider interval of working temperatures (300-1600K) and it permits to investigate the material in the wide range of heat conductivity values (0.5-30 W/(mxK)). The stainless steel 12Kh18N10T, lanthanum sulfide and melted quartz were used for the device calibration. The results obtained and the literature data on these materials agree well between each other

  2. A pragmatic multi-centre randomised controlled trial of fluid loading in high-risk surgical patients undergoing major elective surgery--the FOCCUS study.

    Science.gov (United States)

    Cuthbertson, Brian H; Campbell, Marion K; Stott, Stephen A; Elders, Andrew; Hernández, Rodolfo; Boyers, Dwayne; Norrie, John; Kinsella, John; Brittenden, Julie; Cook, Jonathan; Rae, Daniela; Cotton, Seonaidh C; Alcorn, David; Addison, Jennifer; Grant, Adrian

    2011-01-01

    Fluid strategies may impact on patient outcomes in major elective surgery. We aimed to study the effectiveness and cost-effectiveness of pre-operative fluid loading in high-risk surgical patients undergoing major elective surgery. This was a pragmatic, non-blinded, multi-centre, randomised, controlled trial. We sought to recruit 128 consecutive high-risk surgical patients undergoing major abdominal surgery. The patients underwent pre-operative fluid loading with 25 ml/kg of Ringer's solution in the six hours before surgery. The control group had no pre-operative fluid loading. The primary outcome was the number of hospital days after surgery with cost-effectiveness as a secondary outcome. A total of 111 patients were recruited within the study time frame in agreement with the funder. The median pre-operative fluid loading volume was 1,875 ml (IQR 1,375 to 2,025) in the fluid group compared to 0 (IQR 0 to 0) in controls with days in hospital after surgery 12.2 (SD 11.5) days compared to 17.4 (SD 20.0) and an adjusted mean difference of 5.5 days (median 2.2 days; 95% CI -0.44 to 11.44; P = 0.07). There was a reduction in adverse events in the fluid intervention group (P = 0.048) and no increase in fluid based complications. The intervention was less costly and more effective (adjusted average cost saving: £2,047; adjusted average gain in benefit: 0.0431 quality adjusted life year (QALY)) and has a high probability of being cost-effective. Pre-operative intravenous fluid loading leads to a non-significant reduction in hospital length of stay after high-risk major surgery and is likely to be cost-effective. Confirmatory work is required to determine whether these effects are reproducible, and to confirm whether this simple intervention could allow more cost-effective delivery of care. Prospective Clinical Trials, ISRCTN32188676.

  3. A New Vibration Absorber Design for Under-Chassis Device of a High-Speed Train

    Directory of Open Access Journals (Sweden)

    Yu Sun

    2017-01-01

    Full Text Available To realize the separation of vertical and lateral stiffness of the under-chassis device, a new type of vibration absorber is designed by using the negative stiffness of the disc spring in parallel with the rubber component. To solve its transmission characteristics, harmonic transfer method was used. A rigid-flexible coupling multibody dynamic model of a high-speed train with an elastic car body is established, and the vertical and lateral optimal stiffness of the under-chassis device are calculated. The Sperling index and acceleration PSD of the vehicle with the new vibration absorber and the vehicle with traditional rubber absorber are compared and analyzed. The results show that, with the new vibration absorber, vehicle’s running stability and vibration of the car body are more effective than the vehicle with the traditional rubber absorber.

  4. Significance of coupling device for vessel anastomosis in esophageal reconstruction.

    Science.gov (United States)

    Watanabe, Y; Horiuchi, A; Yamamoto, Y; Kikkawa, H; Kusunose, H; Sugishita, H; Sato, K; Yoshida, M; Yukumi, S; Kawachi, K

    2005-01-01

    To prevent an anastomotic failure due to impaired blood supply, several trials have been performed such as preoperative ischemic conditioning by transarterial embolization of the left gastric, right gastric and splenic arteries or microvascular anastomosis. We assess the significance of an automatic anastomotic coupling device for vessel anastomosis, which we have continuously utilized, to simplify the task and shorten the anastomotic time since March 1999. 8 patients who underwent venous anastomosis by an automatic anastomotic coupling device were evaluated for the time of anastomosis, total ischemic time and outcomes. Venous anastomosis was completed within 5 minutes on average. Microscopic arterial anastomosis by hand took 35 minutes on average. For gastric tube reconstruction, venous anastomosis by an automatic coupling device took only 5 minutes. The top of the gastric tube showed congestion before venous anastomosis, but rapidly recovered from it after anastomosis. Postoperative endoscopic observation of the mucosal color of the replaced intestine or gastric tube was started 3 days after surgery and revealed no ischemia or congestion. The postoperative course was uneventful except one case suffering from pneumonia but leakage was not observed in any case. An automatic anastomotic coupling device can perform an easy and reliable vascular anastomosis for patients who undergo esophageal reconstruction. The device may shorten the operating time and consequently the ischemic time of the gastric tube or jejunal or colonic graft, which in turn may lead to a decrease of complications.

  5. Proceedings of Japan-U.S. workshop P-196 on high heat flux components and plasma surface interactions for next devices

    International Nuclear Information System (INIS)

    Wilson, K.N.; Yamashina, T.

    1993-03-01

    The Japan-US Workshop P-196 was successfully carried out in Kyushu University, Chikushi Campus, from November 17 to 19. The major concern was on the research and development required both for international Thermonuclear Experimental Reactor (ITER) and Large Helical Device (LHD). Most of the discussion items was similar to that of the last workshop, e.g. PFC and PSI in Large Device, High Heat Flux Component, Laboratory Studies and Neutron Damage. The presentation number concerning High Heat Flux Component was largest. (J.P.N.)

  6. High-density plasma etching of III-nitrides: Process development, device applications and damage remediation

    Science.gov (United States)

    Singh, Rajwinder

    Plasma-assisted etching is a key technology for III-nitride device fabrication. The inevitable etch damage resulting from energetic pattern transfer is a challenge that needs to be addressed in order to optimize device performance and reliability. This dissertation focuses on the development of a high-density inductively-coupled plasma (ICP) etch process for III-nitrides, the demonstration of its applicability to practical device fabrication using a custom built ICP reactor, and development of techniques for remediation of etch damage. A chlorine-based standard dry etch process has been developed and utilized in fabrication of a number of electronic and optoelectronic III-nitride devices. Annealing studies carried out at 700°C have yielded the important insight that the annealing time necessary for making good-quality metal contacts to etch processed n-GaN is very short (water, prior to metallization, removes some of the etch damage and is helpful in recovering contact quality. In-situ treatment consisting of a slow ramp-down of rf bias at the end of the etch is found to achieve the same effect as the ex-situ treatment. This insitu technique is significantly advantageous in a large-scale production environment because it eliminates a process step, particularly one involving treatment in hydrochloric acid. ICP equipment customization for scaling up the process to full 2-inch wafer size is described. Results on etching of state of the art 256 x 256 AlGaN focal plane arrays of ultraviolet photodetectors are reported, with excellent etch uniformity over the wafer area.

  7. The high energy multicharged particle exposure of the microbial ecology evaluation device on board the Apollo 16 spacecraft

    Science.gov (United States)

    Benton, E. V.; Henke, R. P.

    1973-01-01

    The high energy multicharged cosmic-ray-particle exposure of the Microbial Ecology Evaluation Device package on board the Apollo 16 spacecraft was monitored using cellulose nitrate, Lexan polycarbonate, nuclear emulsion, and silver chloride crystal nuclear-track detectors. The results of the analysis of these detectors include the measured particle fluences, the linear energy transfer spectra, and the integral atomic number spectrum of stopping particle density. The linear energy transfer spectrum is used to compute the fractional cell loss in human kidney (T1) cells caused by heavy particles. Because the Microbial Ecology Evaluation Device was better shielded, the high-energy multicharged particle exposure was less than that measured on the crew passive dosimeters.

  8. Coagulation profile in patients undergoing video-assisted thoracoscopic lobectomy

    DEFF Research Database (Denmark)

    Christensen, Thomas Decker; Vad, Henrik; Pedersen, Søren

    2017-01-01

    -, and the first two days postoperatively by standard coagulation blood test, thromboelastometry (ROTEM®) and thrombin generation. Results: Patients undergoing potential curative surgery for lung cancer were not hypercoagulable preoperatively. There was no statistically significant difference in the majority......Background: Knowledge about the impact of Low-Molecular-Weight Heparin (LMWH) on the coagulation system in patients undergoing minimal invasive lung cancer surgery is sparse. The aim of this study was to assess the effect of LMWH on the coagulation system in patients undergoing Video......-Assisted Thoracoscopic Surgery (VATS) lobectomy for primary lung cancer. Methods: Sixty-three patients diagnosed with primary lung cancer undergoing VATS lobectomy were randomized to either subcutaneous injection with dalteparin (Fragmin®) 5000 IE once daily or no intervention. Coagulation was assessed pre-, peri...

  9. Advances in biomagnetic research using high- T{sub c} superconducting quantum interference devices

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Hong-Chang [Department of Physics/Institute of Applied Physics, National Taiwan University, Taipei 106, Taiwan (China); Horng, Herng-Er; Yang, S Y [Institute of Electro-Optical Science and Technology, National Taiwan Normal University, Taipei 116, Taiwan (China); Liao, Shu-Hsien, E-mail: hcyang@phys.ntu.edu.t [Department of Physics, National Taiwan Normal University, Taipei 116, Taiwan (China)

    2009-09-15

    This review reports the advances of biomagnetic research using high- T{sub c} superconducting quantum interference devices (SQUIDs). It especially focuses on SQUID-detected magnetocardiography (MCG), magnetically labeled immunoassays (MLIs) as well as nuclear magnetic resonance and imaging (NMR/MRI). The progress in MCG that scientists have made and the encountered challenges are discussed here. This study includes the early detection of the electromagnetic change in cardiac activity in animal studies of hypercholesterolemic rabbits, which suggests the possibility of early diagnosis of cardiac disease in clinical applications. The progress on MLIs using measurements of remanence, magnetic relaxation and magnetic susceptibility reduction is presented. The wash-free immunomagnetic reduction shows both high sensitivity and high specificity. NMR/MRI of high spectral resolution and of high signal-to-noise ratio are addressed and discussed. The proton-phosphate J-coupling of trimethyl phosphate ((CH{sub 3}){sub 3}PO{sub 4}) in one shot in microtesla fields is demonstrated. The prospects of biomagnetic applications are addressed. (topical review)

  10. Nanostructured energy devices equilibrium concepts and kinetics

    CERN Document Server

    Bisquert, Juan

    2014-01-01

    Due to the pressing needs of society, low cost materials for energy devices have experienced an outstanding development in recent times. In this highly multidisciplinary area, chemistry, material science, physics, and electrochemistry meet to develop new materials and devices that perform required energy conversion and storage processes with high efficiency, adequate capabilities for required applications, and low production cost. Nanostructured Energy Devices: Equilibrium Concepts and Kinetics introduces the main physicochemical principles that govern the operation of energy devices. It inclu

  11. Feasibility, physical capacity, and health benefits of a multidimensional exercise program for cancer patients undergoing chemotherapy

    DEFF Research Database (Denmark)

    Adamsen, Lis; Midtgaard, Julie; Rorth, Mikael

    2003-01-01

    Cancer patients frequently experience considerable loss of physical capacity and general wellbeing when diagnosed and treated for their disease. The aim of this study was to evaluate the feasibility, physical capacity, and health benefits of a multidimensional exercise program for cancer patients...... during advanced stages of disease who are undergoing adjuvant or high-dose chemotherapy. The supervised program included high- and low-intensity activities (physical exercise, relaxation, massage, and body-awareness training). A total of 23 patients between 18 and 65 years of age (median 40 years...... significance. It is concluded that an exercise program, which combines high- and low-intensity physical activities, may be used to prevent and/or minimize physical inactivity, fatigue, muscle wasting and energy loss in cancer patients undergoing chemotherapy....

  12. Dental Health of Patients Undergoing Hemodialysis (A Study

    Directory of Open Access Journals (Sweden)

    Vinay Mohan

    2011-01-01

    Full Text Available The primary purpose of this study was to determine the oral manifestations of patients undergoing dialysis. Two subgroups of the population were studied: (1 Those who have been on dialysis for less than one year, (2 those who have been on dialysis for more than one year. Two dental indices–periodontal index and decayed, missing, filled index were used to identify periodontal status, dental canes activity. Data were compiled and analyzed by using the unpaired t-test. Results suggested that 100% (n = 26 of the patients undergoing dialysis presented with some form of periodontal disease (mean value = 2.24, standard deviation = 1.33. Majority of the patients displayed either established periodontal disease (57.6% or the beginning of periodontal disease (38 4%. Approximately, 70% of the patients had high decayed, missing, filled index (mean value = 6.19, standard deviation = 6.40. Findings led to the conclusion that patients on dialysis need comprehensive professional oral care and self-care instructions. The source of infection in oral cavity can cause variety of systemic diseases, causing morbidity and mortality in these immune-suppressed patients.

  13. Micro/Nano Fabricated Solid-State Thermoelectric Generator Devices for Integrated High Voltage Power Sources

    Science.gov (United States)

    Fleurial, J.-P.; Ryan, M. A.; Snyder, G. J.; Huang, C.-K.; Whitacre, J. F.; Patel, J.; Lim, J.; Borshchevsky, A.

    2002-01-01

    Deep space missions have a strong need for compact, high power density, reliable and long life electrical power generation and storage under extreme temperature conditions. Except for electrochemical batteries and solar cells, there are currently no available miniaturized power sources. Conventional power generators devices become inefficient in extreme environments (such as encountered in Mars, Venus or outer planet missions) and rechargeable energy storage devices can only be operated in a narrow temperature range thereby limiting mission duration. The planned development of much smaller spacecrafts incorporating a variety of micro/nanodevices and miniature vehicles will require novel, reliable power technologies. It is also expected that such micro power sources could have a wide range of terrestrial applications, in particular when the limited lifetime and environmental limitations of batteries are key factors. Advanced solid-state thermoelectric combined with radioisotope or waste heat sources and low profile energy storage devices are ideally suited for these applications. The Jet Propulsion Laboratory has been actively pursuing the development of thermoelectric micro/nanodevices that can be fabricated using a combination of electrochemical deposition and integrated circuit processing techniques. Some of the technical challenges associated with these micro/nanodevice concepts, their expected level of performance and experimental fabrication and testing results to date are presented and discussed.

  14. DEVICE TECHNOLOGY. Nanomaterials in transistors: From high-performance to thin-film applications.

    Science.gov (United States)

    Franklin, Aaron D

    2015-08-14

    For more than 50 years, silicon transistors have been continuously shrunk to meet the projections of Moore's law but are now reaching fundamental limits on speed and power use. With these limits at hand, nanomaterials offer great promise for improving transistor performance and adding new applications through the coming decades. With different transistors needed in everything from high-performance servers to thin-film display backplanes, it is important to understand the targeted application needs when considering new material options. Here the distinction between high-performance and thin-film transistors is reviewed, along with the benefits and challenges to using nanomaterials in such transistors. In particular, progress on carbon nanotubes, as well as graphene and related materials (including transition metal dichalcogenides and X-enes), outlines the advances and further research needed to enable their use in transistors for high-performance computing, thin films, or completely new technologies such as flexible and transparent devices. Copyright © 2015, American Association for the Advancement of Science.

  15. Mesooptical Fourier transform microscope - a new device for high energy physics

    International Nuclear Information System (INIS)

    Astakhov, A.Ya.; Batusov, Yu.A.; Bencze, Gy.L.; Farago, I.; Kisvaradi, A.; Molnar, L.; Soroko, L.M.; Vegh, J.

    1988-01-01

    A new device for high energy physics, Mesooptical Fourier Transform Microscope (MFTM), designed for observation of straight-line particle tracks in nuclear emulsion is described. The MFTM works without any mechanical or electronical depth scanning and can be considered as a selectively viewing eye. The computer controlled system containing MFTM as the main unit is given. This system can be used for fast search particle tracks and events produced by high energy neutrinos from accelerators. The results of the first experimental test of the computer controlled MFTM are presented. The performances of this system are described and discussed. It is shown that the angular resolution of the MFTM is 1 angular minute and the measurement time is equal to 30 ms. As all operations in the MFTM go without any depth scanning this new system works at least two orders of magnitude faster than any known system with a traditional optical microscope

  16. Braking materials for emergency stop device of super high speed elevator (810 m/min); 810 m/min erebeta hijo tome sochiyo masatsuzai

    Energy Technology Data Exchange (ETDEWEB)

    Okada, R.; Yamada, T.; Sugahara, J. [Hitachi Ltd., Tokyo (Japan)

    1995-04-20

    Accompanied with a super multistoried building, making the elevator a higher speed is essential and it requires for a performance rise not only on drive unit and control unit, but also on safety device as well, as for especially an emergency stop device to get the cage, which has a kinetic energy proportional to the square of speed, stopped, its performance improvement is indispensable. Because it was anticipated that a braking would become difficult with a speed exceeding 800 m/min by using the iron system materials centering around cast iron used conventionally, an emergency stop device using the special ceramics as a friction material has been developed. In order to develop an elevator with a super high speed of 810 m/min this time, a development of the friction material for emergency stop device, which can brake stably the cage with a kinetic energy substantially exceeding the conventional value, has been advanced. As a result, a strength drop at a high temperature was prevented by adding Cr, Ni and P, and moreover a cast iron with 1,5 times in mean friction coefficient and about 1/10 in specific abrasive quantity compared with FC 250 was developed, and furthermore an emergency stop device with a high performance, which guarantees more than 3 times of braking energy in the emergency stop device of elevator with a speed of 540 m/min, was realized. 5 refs., 8 figs., 1 tab.

  17. Erectile Dysfunction Among HIV Patients Undergoing Highly Active Antiretroviral Therapy: Dyslipidemia as a Main Risk Factor

    Science.gov (United States)

    Romero-Velez, Gustavo; Lisker-Cervantes, Andrés; Villeda-Sandoval, Christian I; Sotomayor de Zavaleta, Mariano; Olvera-Posada, Daniel; Sierra-Madero, Juan Gerardo; Arreguin-Camacho, Lucrecia O; Castillejos-Molina, Ricardo A

    2014-01-01

    Objective To assess the prevalence and risk factors of erectile dysfunction (ED) in HIV patients from the HIV clinic of a tertiary referral center in Mexico City. Design Prevalence was obtained from cross-sectional studies, and the International Index of Erectile Function (IIEF), a standardized method, was used to assess ED. Methods A cross-sectional study was performed in the HIV clinic. Participants completed the IIEF to allow ED assessment. Information on demographics, clinical and HIV-related variables was retrieved from their medical records. Results One hundred and nine patients were included, with a mean age of 39.9 ± 8.8 years. ED was present in 65.1% of the individuals. Patients had been diagnosed with HIV for a mean of 92.7 ± 70.3 months and had undergone a mean 56.4 ± 45.5 months of HAART. The only variable associated with ED in the univariate analysis was dyslipidemia, and this association was also found in the multivariate analysis (P = 0.01). Conclusions ED is highly prevalent in HIV patients. Dyslipidemia should be considered as a risk factor for ED in HIV patients. Romero-Velez G, Lisker-Cervantes A, Villeda-Sandoval CI, Sotomayor de Zavaleta M, Olvera-Posada D, Sierra-Madero JG, Arreguin-Camacho LO, and Castillejos-Molina RA. Erectile dysfunction among HIV patients undergoing highly active antiretroviral therapy: Dyslipidemia as a main risk factor. Sex Med 2014;2:24–30. PMID:25356298

  18. Fully digital data processing during cardiovascular implantable electronic device follow-up in a high-volume tertiary center.

    Science.gov (United States)

    Staudacher, Ingo; Nalpathamkalam, Asha Roy; Uhlmann, Lorenz; Illg, Claudius; Seehausen, Sebastian; Akhavanpoor, Mohammadreza; Buchauer, Anke; Geis, Nicolas; Lugenbiel, Patrick; Schweizer, Patrick A; Xynogalos, Panagiotis; Zylla, Maura M; Scholz, Eberhard; Zitron, Edgar; Katus, Hugo A; Thomas, Dierk

    2017-10-11

    Increasing numbers of patients with cardiovascular implantable electronic devices (CIEDs) and limited follow-up capacities highlight unmet challenges in clinical electrophysiology. Integrated software (MediConnect ® ) enabling fully digital processing of device interrogation data has been commercially developed to facilitate follow-up visits. We sought to assess feasibility of fully digital data processing (FDDP) during ambulatory device follow-up in a high-volume tertiary hospital to provide guidance for future users of FDDP software. A total of 391 patients (mean age, 70 years) presenting to the outpatient department for routine device follow-up were analyzed (pacemaker, 44%; implantable cardioverter defibrillator, 39%; cardiac resynchronization therapy device, 16%). Quality of data transfer and follow-up duration were compared between digital (n = 265) and manual processing of device data (n = 126). Digital data import was successful, complete and correct in 82% of cases when early software versions were used. When using the most recent software version the rate of successful digital data import increased to 100%. Software-based import of interrogation data was complete and without failure in 97% of cases. The mean duration of a follow-up visit did not differ between the two groups (digital 18.7 min vs. manual data transfer 18.2 min). FDDP software was successfully implemented into the ambulatory follow-up of patients with implanted pacemakers and defibrillators. Digital data import into electronic patient management software was feasible and supported the physician's workflow. The total duration of follow-up visits comprising technical device interrogation and clinical actions was not affected in the present tertiary center outpatient cohort.

  19. High-force NdFeB-based magnetic tweezers device optimized for microrheology experiments.

    Science.gov (United States)

    Lin, Jun; Valentine, Megan T

    2012-05-01

    We present the design, calibration, and testing of a magnetic tweezers device that employs two pairs of permanent neodymium iron boron magnets surrounded by low-carbon steel focusing tips to apply large forces to soft materials for microrheology experiments. Our design enables the application of forces in the range of 1-1800 pN to ∼4.5 μm paramagnetic beads using magnet-bead separations in the range of 0.3-20 mm. This allows the use of standard coverslips and sample geometries. A high speed camera, custom LED-based illumination scheme, and mechanically stabilized measurement platform are employed to enable the measurement of materials with viscoelastic moduli as high as ∼1 kPa.

  20. High-force NdFeB-based magnetic tweezers device optimized for microrheology experiments

    Energy Technology Data Exchange (ETDEWEB)

    Lin Jun [Department of Mechanical Engineering, University of California, Santa Barbara, California 93106 (United States); Biomolecular Science and Engineering Program, University of California, Santa Barbara, California 93106 (United States); Valentine, Megan T. [Department of Mechanical Engineering, University of California, Santa Barbara, California 93106 (United States)

    2012-05-15

    We present the design, calibration, and testing of a magnetic tweezers device that employs two pairs of permanent neodymium iron boron magnets surrounded by low-carbon steel focusing tips to apply large forces to soft materials for microrheology experiments. Our design enables the application of forces in the range of 1-1800 pN to {approx}4.5 {mu}m paramagnetic beads using magnet-bead separations in the range of 0.3-20 mm. This allows the use of standard coverslips and sample geometries. A high speed camera, custom LED-based illumination scheme, and mechanically stabilized measurement platform are employed to enable the measurement of materials with viscoelastic moduli as high as {approx}1 kPa.

  1. An experimental analysis on property and structure variations of agricultural wastes undergoing torrefaction

    International Nuclear Information System (INIS)

    Chen, Wei-Hsin; Lu, Ke-Miao; Tsai, Chi-Ming

    2012-01-01

    Highlights: ► Coffee residue, sawdust and rice husk undergoing torrefaction are investigated. ► A high-volatile bituminous coal and a low-volatile one are also regarded for comparison. ► Coffee residue is the most active biomass to torrefaction. ► Torrefied wastes approach the high-volatile coal as increasing temperature and duration. ► Torrefaction is conducive to the applications of biomass in industrial furnaces. -- Abstract: Three agricultural wastes, consisting of coffee residue, sawdust and rice husk, undergoing torrefaction are investigated to evaluate the potential of biomass as solid fuel. Two different torrefaction temperatures (240 and 270 °C) and durations (0.5 and 1 h) are considered in the study, and the properties and structures of the raw and torrefied wastes are extensively investigated by means of proximate, elemental, fiber, calorific, thermogravimetric, SEM and FTIR analyses. A high-volatile bituminous coal and a low-volatile one are also regarded for comparison. By virtue of more hemicellulose contained in the coffee residue, it is the most active biomass to torrefaction and its higher heating value (HHV) is improved up to 38%. The empirical atomic formula of the raw wastes is expressed by CH 1.54–1.76 O 0.65–0.89 and it changes to CH 1.02–1.57 O 0.26–0.64 after undergoing torrefaction. The torrefied biomasses approach high-volatile coal when the torrefaction temperature and duration increase. From fuel point of view, the improved properties and changed molecular structure are conducive to the applications of biomass in industrial furnaces such as boilers and blast furnaces.

  2. High temperature superconducting devices for SQUIDs, HF- and FIR-applications. Subproject: Thin-film heterostructures for devices and loss mechanisms in HTS. Final report

    International Nuclear Information System (INIS)

    Froehlich, O.

    1994-06-01

    The successful use of electronic devices fabricated from the High Temperature Superconductors (HTS) in SQUID systems as well as HF- and FIR-applications requires the development of a suitable thin-film and device technology. Within the present research project we successfully established the technological base for the deposition and patterning of epitaxial HTS thin-films (YBaCuO, NdCeCuO) and heterostructures of HTS and insulating materials (e.g. NdGaO 3 ). YBaCuO/NdCeCuO superlattices could be successfully fabricated such that both components of the hterostructure were in a superconducting state. This allows for the fabrication and study of superconducting p-n structures. With respect to the fabrication of single grain boundary Josephson junctions based on the bicrystal technique we could establish an international leadership. The small spread of the junction parameters (∝20%) allowed the controllable fabrication of simple devices such as SQUIDs or flux-flow transistors. By the development of a new measuring technique the homogeneity of the critical current density distribution in grain-boundary junctions could be investigated on a sub-μm-scale. Within this project we also could establish a good understanding of the physical background of the transport phenomena in the mixed state of HTS in the presence of a temperature gradient. (orig./MM) [de

  3. Green Fluorescent Organic Light Emitting Device with High Luminance

    Directory of Open Access Journals (Sweden)

    Ning YANG

    2014-06-01

    Full Text Available In this work, we fabricated the small molecule green fluorescent bottom-emission organic light emitting device (OLED with the configuration of glass substrate/indium tin oxide (ITO/Copper Phthalocyanine (CuPc 25 nm/ N,N’-di(naphthalen-1-yl-N,N’-diphenyl-benzidine (NPB 45 nm/ tris(8-hydroxyquinoline aluminium (Alq3 60 nm/ Lithium fluoride (LiF 1 nm/Aluminum (Al 100 nm where CuPc and NPB are the hole injection layer and the hole transport layer, respectively. CuPc is introduced in this device to improve carrier injection and efficiency. The experimental results indicated that the turn-on voltage is 2.8 V with a maximum luminance of 23510 cd/m2 at 12 V. The maximum current efficiency and power efficiency are 4.8 cd/A at 100 cd/m2 and 4.2 lm/W at 3 V, respectively. The peak of electroluminance (EL spectrum locates at 530 nm which is typical emission peak of green light. In contrast, the maximum current efficiency and power efficiency of the device without CuPc are only 4.0 cd/A at 100 mA/cm2 and 4.2 lm/W at 3.6 V, respectively.

  4. Safety and efficacy of cervical laminoplasty using a piezosurgery device compared with a high-speed drill.

    Science.gov (United States)

    Li, Kunpeng; Zhang, Wen; Li, Bin; Xu, Hui; Li, Zhong; Luo, Dawei; Zhang, Jingtao; Ma, Jinzhu

    2016-09-01

    Piezosurgery is a relatively new osteotomy technique using microvibrations of scalpels at ultrasonic frequencies to perform safe and effective osteotomies without damage to adjacent soft tissue, which is widely used in spinal, oral, and maxillofacial surgery. We hypothesized that such a device could also be useful in cervical laminoplasty. The purpose of this study was to compare the safety and efficacy of a piezosurgery device with those of a highspeed drill in cervical laminoplasty. A prospectively randomized clinical study was designed. Forty-two consecutive patients were enrolled in the study. All patients underwent modified expansive open-door laminoplasty and were randomly divided into 2 groups according to the instrument for transection of the lamina, using high-speed drill (drill group) or piezosurgery device (piezosurgery group). The operation time, intraoperative blood loss, and postoperative drainage were recorded. Japanese Orthopedic Association (JOA) score and visual analogue scale (VAS) as clinical assessments were quantified. No significant difference was observed in the operation time between the 2 groups. In the piezosurgery group, there were less loss of the intraoperative blood and postoperative drainage compared with the drill group. However, clinical results (VAS and JOA scores) showed no significant difference between both groups during the all follow-up periods. The piezosurgery is a useful instrument and at least as safe and efficacious as the conventional high-speed drill in cervical laminoplasty.

  5. Proton therapy device

    International Nuclear Information System (INIS)

    Tronc, D.

    1994-01-01

    The invention concerns a proton therapy device using a proton linear accelerator which produces a proton beam with high energies and intensities. The invention lies in actual fact that the proton beam which is produced by the linear accelerator is deflected from 270 deg in its plan by a deflecting magnetic device towards a patient support including a bed the longitudinal axis of which is parallel to the proton beam leaving the linear accelerator. The patient support and the deflecting device turn together around the proton beam axis while the bed stays in an horizontal position. The invention applies to radiotherapy. 6 refs., 5 figs

  6. Real-time x-ray response of biocompatible solution gate AlGaN/GaN high electron mobility transistor devices

    International Nuclear Information System (INIS)

    Hofstetter, Markus; Funk, Maren; Paretzke, Herwig G.; Thalhammer, Stefan; Howgate, John; Sharp, Ian D.; Stutzmann, Martin

    2010-01-01

    We present the real-time x-ray irradiation response of charge and pH sensitive solution gate AlGaN/GaN high electron mobility transistors. The devices show stable and reproducible behavior under and following x-ray radiation, including a linear integrated response with dose into the μGy range. Titration measurements of devices in solution reveal that the linear pH response and sensitivity are not only retained under x-ray irradiation, but an irradiation response could also be measured. Since the devices are biocompatible, and can be simultaneously operated in aggressive fluids and under hard radiation, they are well-suited for both medical radiation dosimetry and biosensing applications.

  7. Teacher Implementation of "Bring Your Own Device" at a Suburban High School Serving High SES Students

    Science.gov (United States)

    Ross, Kyle

    2013-01-01

    As students gain access to personally-owned Mobile Communication Devices (MCDs), schools have begun to embrace MCDs as mobile-learning (m-learning) teaching and learning tools. A research gap currently exists for the innovation of m-learning with student-owned devices, which this study attempts to fill by answering the following Research Question:…

  8. The Effectiveness of the High-Tech Speech-Generating Device with Proloquo2Go App in Reducing Echolalia Utterances in a Student with Autism

    Science.gov (United States)

    Alrusayni, Norah

    2017-01-01

    This study was conducted to determine the effectiveness of using the high-tech speech-generating device with Proloquo2Go app to reduce echolalic utterances in a student with autism during conversational speech. After observing that the iPad device with several apps was used by the students and that it served as a communication device, language…

  9. Apparatus for testing semiconductor devices and capacitors

    International Nuclear Information System (INIS)

    York, R.A.

    1984-01-01

    An apparatus is provided for testing semiconductor devices. The apparatus tests the impedance of the semiconductor devices in both conducting and non-conducting states to detect semiconductors whose impedance in the conducting state is too high or whose impedance in the non-conducting state is too low. The apparatus uses a battery source for low voltage d.c. The circuitry for detecting when the impedance is too high in the conducting state includes a lamp in series with the battery source and the semiconductor device, whereby the impedance of the semiconductor device determines whether sufficient current will flow through the lamp to cause the lamp to illuminate. A d.c. to d.c. converter is provided to boost the voltage from the battery source to a relatively high voltage d.c. The relatively high voltage d.c. can be connected by a switch to circuitry for detecting when the impedance of the semiconductor device in the non-conducting state is too low. The circuitry for detecting when the impedance of the semiconductor device is too low includes a resistor which senses the current flowing in the device and converts the current into a voltage proportional to the leakage current. This voltage is then compared against a fixed reference. Further circuitry is provided for providing a visual indication when the voltage representative of leakage in relation to the reference signal indicates that there is excessive current flow through the semiconductor device

  10. Immediate arterial hemostasis after cardiac catheterization: initial experience with a new puncture closure device.

    Science.gov (United States)

    Aker, U T; Kensey, K R; Heuser, R R; Sandza, J G; Kussmaul, W G

    1994-03-01

    A novel device for obtaining arterial hemostasis after invasive procedures was tested in 30 patients undergoing diagnostic catheterization (26 patients) or coronary angioplasty (4 patients). The device is deployed through an arterial sheath and forms a positive mechanical seal both inside and outside the defect in the arterial wall. The components are all bioabsorbable. Thirteen patients received a heparin bolus during the catheterization procedure. The activated clotting time recorded in 15 patients just prior to device deployment averaged 264 sec. 29 of 32 attempted device deployments were successful (91%); and the remaining 3 devices pulled completely out as called for by design in the event of incomplete deployment. Twenty-nine patients ultimately achieved successful hemostasis using the device, with the other patient receiving manual hemostasis. Of these 29, hemostasis was immediate and complete in 19 patients. Light digital pressure was required in another 8 patients for less than 5 min. There was minor delayed bleeding requiring supplemental light pressure in several cases. A total of 11 patients required supplemental pressure in addition to the hemostasis device. The use of bolus heparin was significantly (P = 0.05, Fisher's exact test) related to the requirement for supplemental pressure. Three patients developed hematomas, one of which was present prior to device deployment. The other two patients had received bolus heparin. No patient required transfusion or surgical repair. There was no change in the ankle/brachial systolic blood pressure index after device deployment or at late (30-60 day) follow-up. Ultrasound studies revealed no significant pathology relative to the device.(ABSTRACT TRUNCATED AT 250 WORDS)

  11. Use of extraglottic airways in patients undergoing ambulatory laparoscopic surgery without the need for tracheal intubation

    Directory of Open Access Journals (Sweden)

    T Suhitharan

    2013-01-01

    Full Text Available Background: Second generation extraglottic airway devices with gastric access and separate breathing channels have ushered in a new era where their use is increasingly prevalent in surgical patients who would have been traditionally intubated for general anesthesia. New innovations like the i-gel, which is constructed of a thermoplastic elastomer, provide an airtight seal around patient′s perilaryngeal anatomy without the inflatable cuff mechanism found in the laryngeal mask airway supreme (LMAS. Methods: We conducted a randomized controlled trial comparing the LMAS with the i-gel in 70 anesthetized paralyzed patients undergoing laparoscopic female sterilization. Our primary outcome measure was the oropharyngeal leak pressure (OLP. We studied secondary outcomes of successful first attempt insertion rates, time and ease of the airway and gastric tube insertion, leak fractions and pharyngeal morbidity. Results: We found no difference in the OLP between LMAS and i-gel, 25.9 (4.2 versus 24.4 (4.3 s, P=0.153. Both devices had similar first attempt insertion rates (LMAS 94% vs. i-gel 91% with similar ease and comparable times to achieve an effective airway, LMAS 14.7 (2.7 versus i-gel 16.5 (9.6 s, P=0.306, although gastric tube insertion was easier and faster for the LMAS, 7.9 (1.9 versus i-gel 14.8 (7.7 s, P<0.005. Intraoperatively, there was a significantly greater leak fraction with the i-gel of 0.06 (0.03 versus 0.04 (0.02 with the LMAS, P=0.013. Three patients (8.6% with LMAS had mild sore throat; one patient (2.9% had mucosal injury. No complications were documented in the i-gel group. Conclusions: Both these extraglottic airway devices offer similar OLPs, high insertion success rates at the first attempt with similar ease and insertion times (albeit longer gastric tube insertion with i-gel. Both provided effective ventilation despite a higher leak fraction with i-gel that was clinically inconsequential.

  12. Subcutaneously administered Menopur(R, a new highly purified human menopausal gonadotropin, causes significantly fewer injection site reactions than Repronex(R in subjects undergoing in vitro fertilization

    Directory of Open Access Journals (Sweden)

    Somkuti Stephen

    2005-11-01

    Full Text Available Abstract Background The safety and tolerability of a new highly purified, urine-derived human menopausal gonadotropin (hMG preparation [Menopur(R] was compared with a currently available hMG [Repronex (R] in women undergoing in vitro fertilization (IVF. Methods This was a randomized, open-label, parallel-group, multicenter study conducted in subjects undergoing IVF. Women (N = 125, 18–39 years of age, underwent pituitary down-regulation with leuprolide acetate beginning 7 days prior to onset of menses and continuing up to the day before hCG administration. Subjects were randomized to receive subcutaneous (SC Menopur (R (n = 61 or Repronex (R SC (n = 64 for a maximum of 12 days. All adverse events (AEs were recorded and subject self-assessments of injection site reactions were recorded in a daily diary. Results Significantly fewer subjects in the Menopur (R group reported injection site reactions (P Conclusion Menopur (R SC offers a greater safety and tolerability profile compared to Repronex (R SC.

  13. Evaluation of the perceptions and cosmetic satisfaction of breast cancer patients undergoing totally implantable vascular access device (TIVAD) placement.

    Science.gov (United States)

    Liberale, Gabriel; El Houkayem, Michel; Viste, Claire; Bouazza, Fikri; Moreau, Michel; El Nakadi, Issam; Veys, Isabelle

    2016-12-01

    Totally implantable vascular access devices (TIVADs) are widely used to administer chemotherapy to cancer patients. While great progress has been made with respect to breast surgical reconstruction to take into account both aesthetics and patients' perceptions of body integrity, these aspects have not been considered with regard to the impact of TIVAD. In order to address this practice gap, we have adapted our TIVAD implantation technique to improve cosmetic results. The aim of this study was to assess breast cancer patients' comfort level and aesthetic satisfaction with regard to TIVAD insertion. Patients with breast cancer admitted for chemotherapy at an outpatient clinic completed a previously validated survey evaluating three main domains: symptoms (pain, discomfort) related to the TIVAD itself in daily activity, information received before and during the surgical procedure, and cosmetic aspects regarding the port insertion site (scar, port, and catheter location). Between September 2010 and June 2011, 232 patients were evaluated. Cosmetic satisfaction with scar location was high (93.3 %). Information given to patients before and during the procedure had a major impact on both symptom perception in daily activity and on cosmetic satisfaction. Obtaining a more aesthetic scar by placing the TIVAD in the deltopectoral groove contributed to a high rate of cosmetic satisfaction. Furthermore, the relevance of information given to patients before and/or during surgery had a major impact on symptom perception. Therefore, we suggest including a pre-operative information session in the care pathway.

  14. [Wireless device for monitoring the patients with chronic disease].

    Science.gov (United States)

    Ciorap, R; Zaharia, D; Corciovă, C; Ungureanu, Monica; Lupu, R; Stan, A

    2008-01-01

    Remote monitoring of chronic diseases can improve health outcomes and potentially lower health care costs. The high number of the patients, suffering of chronically diseases, who wish to stay at home rather then in a hospital increasing the need of homecare monitoring and have lead to a high demand of wearable medical devices. Also, extended patient monitoring during normal activity has become a very important target. In this paper are presented the design of the wireless monitoring devices based on ultra low power circuits, high storage memory flash, bluetooth communication and the firmware for the management of the monitoring device. The monitoring device is built using an ultra low power microcontroller (MSP430 from Texas Instruments) that offers the advantage of high integration of some circuits. The custom made electronic boards used for biosignal acquisition are also included modules for storage device (SD/MMC card) with FAT32 file system and Bluetooth device for short-range communication used for data transmission between monitoring device and PC or PDA. The work was focused on design and implementation of an ultra low power wearable device able to acquire patient vital parameters, causing minimal discomfort and allowing high mobility. The proposed wireless device could be used as a warning system for monitoring during normal activity.

  15. Optimization of a variable-stiffness skin for morphing high-lift devices

    International Nuclear Information System (INIS)

    Thuwis, G A A; Abdalla, M M; Gürdal, Z

    2010-01-01

    One of the possibilities for the next generation of smart high-lift devices is to use a seamless morphing structure. A passive composite variable-stiffness skin as a solution to the dilemma of designing the structure to have high enough stiffness to withstand aerodynamic loading and low stiffness to enable morphing is proposed. The variable-stiffness skin is achieved by allowing for a spatial fibre angle and skin thickness variation on a morphing high-lift system. The stiffness distribution is tailored to influence the deformation of the structure beneficially. To design a realistic stiffness distribution, it is important to take aerodynamic and actuation loads into account during the optimization. A two-dimensional aero-servo-elastic framework is created for this purpose. Skin optimization is performed using a gradient-based optimizer, where sensitivity information is found through application of the adjoint method. The implementation of the aero-servo-elastic environment is addressed and initial optimization results presented. The results indicate that a variable-stiffness skin increases the design space. Moreover, the importance of taking the change in aerodynamic loads due to morphing skin deformation into account during optimization is demonstrated

  16. Chalcogenide glasses for device application modified by high-energy irradiation

    International Nuclear Information System (INIS)

    Kavetskyy, T.; Shpotyuk, O.

    2006-01-01

    Full text: Chalcogenide glasses (ChG) or chemical compounds of chalcogen atoms (S, Se or Te, but not O) with some elements from IV-th and V-th groups of the Periodic Table (typically As, Ge, Sb, Bi, etc. ) obtained by melt quenching, are a perspective for application in modern optoelectronics, photonics, telecommunications, acoustic-optics, xerography, lithography, etc. This uniqueness is due to extremely high sensitivity of ChG to external influences, associated, presumably, with high steric flexibility proper to glassy-like network with low average atomic coordination (chalcogen atoms are typically two-fold coordinated in a glassy-like network), relatively large internal free volume and specific lp-character of electronic states localized at a valence-band top. However, at present, the further possibilities for conventional chemical/technological methods to prepare ChG are fully exhausted. One of the steps to resolve this problem is post-technological modification of ChG using possibilities of high-energy irradiation. This work is focused on new advanced radiation-modified ChG for device application in optoelectronics. The attractive practical use of these non-crystalline materials is tightly connected with radiation-induced defect formation processes. For the first time, we consider the possibilities of Raman scattering along with X-ray diffraction and positron annihilation lifetime spectroscopy to characterize microstructural mechanisms of radiation-induced effects in ChG. (authors)

  17. Device Optimization and Transient Electroluminescence Studies of Organic light Emitting Devices

    Energy Technology Data Exchange (ETDEWEB)

    Lijuan Zou

    2003-08-05

    Organic light emitting devices (OLEDs) are among the most promising for flat panel display technologies. They are light, bright, flexible, and cost effective. And while they are emerging in commercial product, their low power efficiency and long-term degradation are still challenging. The aim of this work was to investigate their device physics and improve their performance. Violet and blue OLEDs were studied. The devices were prepared by thermal vapor deposition in high vacuum. The combinatorial method was employed in device preparation. Both continuous wave and transient electroluminescence (EL) were studied. A new efficient and intense UV-violet light emitting device was developed. At a current density of 10 mA/cm{sup 2}, the optimal radiance R could reach 0.38 mW/cm{sup 2}, and the quantum efficiency was 1.25%. using the delayed EL technique, electron mobilities in DPVBi and CBP were determined to be {approx} 10{sup -5} cm{sup 2}/Vs and {approx} 10{sup -4} cm{sup 2}/Vs, respectively. Overshoot effects in the transient El of blue light emitting devices were also observed and studied. This effect was attributed to the charge accumulation at the organic/organic and organic/cathode interfaces.

  18. Device Optimization and Transient Electroluminescence Studies of Organic light Emitting Devices

    International Nuclear Information System (INIS)

    Lijuan Zou

    2003-01-01

    Organic light emitting devices (OLEDs) are among the most promising for flat panel display technologies. They are light, bright, flexible, and cost effective. And while they are emerging in commercial product, their low power efficiency and long-term degradation are still challenging. The aim of this work was to investigate their device physics and improve their performance. Violet and blue OLEDs were studied. The devices were prepared by thermal vapor deposition in high vacuum. The combinatorial method was employed in device preparation. Both continuous wave and transient electroluminescence (EL) were studied. A new efficient and intense UV-violet light emitting device was developed. At a current density of 10 mA/cm 2 , the optimal radiance R could reach 0.38 mW/cm 2 , and the quantum efficiency was 1.25%. using the delayed EL technique, electron mobilities in DPVBi and CBP were determined to be ∼ 10 -5 cm 2 /Vs and ∼ 10 -4 cm 2 /Vs, respectively. Overshoot effects in the transient El of blue light emitting devices were also observed and studied. This effect was attributed to the charge accumulation at the organic/organic and organic/cathode interfaces

  19. Management of long-term and reversible hysteroscopic sterilization: a novel device with nickel-titanium shape memory alloy

    Science.gov (United States)

    2014-01-01

    Background Female sterilization is the second most commonly used method of contraception in the United States. Female sterilization can now be performed through laparoscopic, abdominal, or hysteroscopic approaches. The hysteroscopic sterilization may be a safer option than sterilization through laparoscopy or laparotomy because it avoids invading the abdominal cavity and undergoing general anaesthesia. Hysteroscopic sterilization mainly includes chemical agents and mechanical devices. Common issues related to the toxicity of the chemical agents used have raised concerns regarding this kind of contraception. The difficulty of the transcervical insertion of such mechanical devices into the fallopian tubes has increased the high incidence of device displacement or dislodgment. At present, Essure® is the only commercially available hysteroscopic sterilization device being used clinically. The system is irreversible and is not effective immediately. Presentation of the hypothesis Our new hysteroscopic sterility system consists of nickel-titanium (NiTi) shape memory alloy and a waterproof membrane. The NiTi alloy is covered with two coatings to avoid toxic Ni release and to prevent stimulation of epithelial tissue growth around the oviducts. Because of the shape memory effect of the NiTi alloy, the device works like an umbrella: it stays collapsed at low temperature before placement and opens by the force of shape memory activated by the body temperature after it is inserted hysteroscopically into the interstitial tubal lumen. The rim of the open device will incise into interstitial myometrium during the process of unfolding. Once the device is fixed, it blocks the tube completely. When the patient no longer wishes for sterilization, the device can be closed by perfusing liquid with low temperature into the uterine cavity, followed by prospective hysteroscopic removal. After the device removal, the fallopian tube will revert to its physiological functions. Testing the

  20. Charging device for an electrostatic accelerator

    International Nuclear Information System (INIS)

    Pivovar, L.I.; Khurgin, K.M.

    1983-01-01

    The invention relates to electrostatic accelerators operating in compressed gases and charged by a charge-carrying belt transport device with driving and driven shafts. The aim of the invention is the increase of service life of the device by decreasing deflection of the charge-carrying belt in high-voltage conductor operation at high voltages. Increase of survice life of the device is provided due to the fact that the belt as a whole is more stable and it runs true without slacking shielding rods

  1. On-line Monitoring Device for High-voltage Switch Cabinet Partial Discharge Based on Pulse Current Method

    Science.gov (United States)

    Y Tao, S.; Zhang, X. Z.; Cai, H. W.; Li, P.; Feng, Y.; Zhang, T. C.; Li, J.; Wang, W. S.; Zhang, X. K.

    2017-12-01

    The pulse current method for partial discharge detection is generally applied in type testing and other off-line tests of electrical equipment at delivery. After intensive analysis of the present situation and existing problems of partial discharge detection in switch cabinets, this paper designed the circuit principle and signal extraction method for partial discharge on-line detection based on a high-voltage presence indicating systems (VPIS), established a high voltage switch cabinet partial discharge on-line detection circuit based on the pulse current method, developed background software integrated with real-time monitoring, judging and analyzing functions, carried out a real discharge simulation test on a real-type partial discharge defect simulation platform of a 10KV switch cabinet, and verified the sensitivity and validity of the high-voltage switch cabinet partial discharge on-line monitoring device based on the pulse current method. The study presented in this paper is of great significance for switch cabinet maintenance and theoretical study on pulse current method on-line detection, and has provided a good implementation method for partial discharge on-line monitoring devices for 10KV distribution network equipment.

  2. Radioactive gas storage device

    International Nuclear Information System (INIS)

    Seki, Eiji; Kobayashi, Yoshihiro.

    1989-01-01

    The present invention concerns a device of ionizing radioactive gases to be processed in gaseous nuclear fission products in nuclear fuel reprocessing plants, etc., and injecting them into metal substrates for storage. The device comprises a vessel for a tightly closed type outer electrode in which gases to be processed are introduced, an electrode disposed to the inside of the vessel and the target material, a high DC voltage power source for applying high voltage to the electrodes, etc. There are disposed a first electric discharging portion for preparting discharge plasma for ion injection of different electrode distance and a second electric discharging portion for causing stable discharge between the vessel and the electrode. The first electric discharging portion for the ion injection provides an electrode distance suitable to acceleration sputtering and the second electric discharging portion is used for stable discharge. Accordingly, if the gas pressure in the radioactive gas storage device is reduced by the external disturbance, etc., since the second electric discharging portion satisfies the electric discharging conditions, the device can continue electric discharge. (K.M.)

  3. Integrated titanium dioxide (TiO_2) nanoparticles on interdigitated device electrodes (IDEs) for pH analysis

    International Nuclear Information System (INIS)

    Azizah, N.; Gopinath, Subash C. B.; Nadzirah, Sh.; Farehanim, M. A.; Fatin, M. F.; Ruslinda, A. R.; Hashim, U.; Arshad, M. K. Md.; Ayub, R. M.

    2016-01-01

    Titanium dioxide (TiO_2) nanoparticles based Interdigitated Device Electrodes (IDEs) Nanobiosensor device was developed for intracellular biochemical detection. Fabrication and characterization of pH sensors using IDE nanocoated with TiO_2 was studied in this paper. In this paper, a preliminary assessment of this intracellular sensor with electrical measurement under different pH levels. 3-aminopropyltriethoxysilane (APTES) was used to enhance the sensitivity of titanium dioxide layer as well as able to provide surface modification by undergoing protonation and deprotonation process. Different types of pH solution provide different resistivity and conductivity towards the surface. Base solution has the higher current compared to an acid solution. Amine and oxide functionalized TiO_2 based IDE exhibit pH-dependent could be understood in terms of the change in surface charge during protonation and deprotonation. The simple fabrication process, high sensitivity, and fast response of the TiO_2 based IDEs facilitate their applications in a wide range of areas. The small size of semiconductor TiO_2 based IDE for sensitive, label-free, real time detection of a wide range of biological species could be explored in vivo diagnostics and array-based screening.

  4. Chemical etching of Tungsten thin films for high-temperature surface acoustic wave-based sensor devices

    Energy Technology Data Exchange (ETDEWEB)

    Spindler, M., E-mail: m.spindler@ifw-dresden.de [IFW Dresden, SAWLab Saxony, P.O. Box 270116, D-01171 Dresden (Germany); Herold, S.; Acker, J. [BTU Cottbus – Senftenberg, Faculty of Sciences, P.O. Box 101548, 01968 Senftenberg (Germany); Brachmann, E.; Oswald, S.; Menzel, S.; Rane, G. [IFW Dresden, SAWLab Saxony, P.O. Box 270116, D-01171 Dresden (Germany)

    2016-08-01

    Surface acoustic wave devices are widely used as wireless sensors in different application fields. Recent developments aimed to utilize those devices as temperature sensors even in the high temperature range (T > 300 °C) and in harsh environmental conditions. Therefore, conventional materials, which are used for the substrate and for the interdigital transducer finger electrodes such as multilayers or alloys based on Al or Cu have to be exchanged by materials, which fulfill some important criteria regarding temperature related effects. Electron beam evaporation as a standard fabrication method is not well applicable for depositing high temperature stable electrode materials because of their very high melting points. Magnetron sputtering is an alternative deposition process but is also not applicable for lift-off structuring without any further improvement of the structuring process. Due to a relatively high Ar gas pressure of about 10{sup −1} Pa, the sidewalls of the photoresist line structures are also covered by the metallization, which subsequently prevents a successful lift-off process. In this study, we investigate the chemical etching of thin tungsten films as an intermediate step between magnetron sputtering deposition of thin tungsten finger electrodes and the lift-off process to remove sidewall covering for a successful patterning process of interdigital transducers. - Highlights: • We fabricated Tungsten SAW Electrodes by magnetron sputtering technology. • An etching process removes sidewall covering of photoresist, which allows lift-off. • Tungsten etching rates based on a hydrogen peroxide solutions were determined.

  5. The future of the pharmaceutical, biological and medical device industry

    Directory of Open Access Journals (Sweden)

    Burgess LJ

    2011-09-01

    Full Text Available Lesley J Burgess, Marli TerblancheTREAD Research/Cardiology Unit, Department of Internal Medicine, Tygerberg Hospital and University of Stellenbosch, Parow, South AfricaAbstract: Numerous factors contribute to the declining pharmaceutical industry on the one hand and the rapidly growing generic industry together with the growing importance of medical devices and biologicals on the other. It is clear that the pharmaceutical industry is going to undergo a change in the next decade in order to meet the current challenges facing it and ultimately sustain its profitability and growth. This paper aims to identify a number of fairly obvious trends that are likely to have a significant impact on the product development pipeline in the next decade. It is more than clear that the current production pipeline for pharmaceutical, biotechnology and medical device industries is no longer sustainable and that urgent interventions are required in order to maintain its current level of profitability.Keywords: pharmaceutical industry, personalized medicine, trends, generics, biotechnology

  6. Design optimization of pixel sensors using device simulations for the phase-II CMS tracker upgrade

    Science.gov (United States)

    Jain, G.; Bhardwaj, A.; Dalal, R.; Eber, R.; Eichorn, T.; Fernandez, M.; Lalwani, K.; Messineo, A.; Palomo, F. R.; Peltola, T.; Printz, M.; Ranjan, K.; Villa, I.; Hidalgo, S.; CMS Collaboration

    2016-07-01

    In order to address the problems caused by the harsh radiation environment during the high luminosity phase of the LHC (HL-LHC), all silicon tracking detectors (pixels and strips) in the CMS experiment will undergo an upgrade. And so to develop radiation hard pixel sensors, simulations have been performed using the 2D TCAD device simulator, SILVACO, to obtain design parameters. The effect of various design parameters like pixel size, pixel depth, implant width, metal overhang, p-stop concentration, p-stop depth and bulk doping density on the leakage current and critical electric field are studied for both non-irradiated as well as irradiated pixel sensors. These 2D simulation results of planar pixels are useful for providing insight into the behaviour of non-irradiated and irradiated silicon pixel sensors and further work on 3D simulation is underway.

  7. Design optimization of pixel sensors using device simulations for the phase-II CMS tracker upgrade

    International Nuclear Information System (INIS)

    Jain, G.; Bhardwaj, A.; Dalal, R.; Eber, R.; Eichorn, T.; Fernandez, M.; Lalwani, K.; Messineo, A.; Palomo, F.R.; Peltola, T.; Printz, M.; Ranjan, K.; Villa, I.; Hidalgo, S.

    2016-01-01

    In order to address the problems caused by the harsh radiation environment during the high luminosity phase of the LHC (HL-LHC), all silicon tracking detectors (pixels and strips) in the CMS experiment will undergo an upgrade. And so to develop radiation hard pixel sensors, simulations have been performed using the 2D TCAD device simulator, SILVACO, to obtain design parameters. The effect of various design parameters like pixel size, pixel depth, implant width, metal overhang, p-stop concentration, p-stop depth and bulk doping density on the leakage current and critical electric field are studied for both non-irradiated as well as irradiated pixel sensors. These 2D simulation results of planar pixels are useful for providing insight into the behaviour of non-irradiated and irradiated silicon pixel sensors and further work on 3D simulation is underway.

  8. Design optimization of pixel sensors using device simulations for the phase-II CMS tracker upgrade

    Energy Technology Data Exchange (ETDEWEB)

    Jain, G., E-mail: geetikajain.hep@gmail.com [CDRST, Department of Physics & Astrophysics, University of Delhi, Delhi (India); Bhardwaj, A.; Dalal, R. [CDRST, Department of Physics & Astrophysics, University of Delhi, Delhi (India); Eber, R. [Institute fur Experimentelle Kernphysik (Germany); Eichorn, T. [Deutsches Elektronen Synchrotron (Germany); Fernandez, M. [Instituto de Fisica de Cantabria (Spain); Lalwani, K. [CDRST, Department of Physics & Astrophysics, University of Delhi, Delhi (India); Messineo, A. [Universita di Pisa & INFN sez. di Pisa (Italy); Palomo, F.R. [Escuela Superior de Ingenieros, Universidad de Sevilla (Spain); Peltola, T. [Helsinki Institute of Physics (Finland); Printz, M. [Institute fur Experimentelle Kernphysik (Germany); Ranjan, K. [CDRST, Department of Physics & Astrophysics, University of Delhi, Delhi (India); Villa, I. [Instituto de Fisica de Cantabria (Spain); Hidalgo, S. [Instituto de Microelectronica de Barcelona, Centro Nacional de Microelectronica (Spain)

    2016-07-11

    In order to address the problems caused by the harsh radiation environment during the high luminosity phase of the LHC (HL-LHC), all silicon tracking detectors (pixels and strips) in the CMS experiment will undergo an upgrade. And so to develop radiation hard pixel sensors, simulations have been performed using the 2D TCAD device simulator, SILVACO, to obtain design parameters. The effect of various design parameters like pixel size, pixel depth, implant width, metal overhang, p-stop concentration, p-stop depth and bulk doping density on the leakage current and critical electric field are studied for both non-irradiated as well as irradiated pixel sensors. These 2D simulation results of planar pixels are useful for providing insight into the behaviour of non-irradiated and irradiated silicon pixel sensors and further work on 3D simulation is underway.

  9. Scanning device for a spectrometer

    International Nuclear Information System (INIS)

    Ignat'ev, V.M.

    1982-01-01

    The invention belongs to scanning devices and is intended for spectrum scanning in spectral devices. The purpose of the invention is broadening of spectral scanning range. The device construction ensures the spectrum scanning range determined from revolution fractions to several revolutions of the monochromator drum head, any number of the drum head revolutions determined by integral number with addition of the drum revolution fractions with high degree of accuracy being possible

  10. Multipurpose high-pressure high-temperature diamond-anvil cell with a novel high-precision guiding system and a dual-mode pressurization device

    Science.gov (United States)

    Pippinger, Thomas; Miletich, Ronald; Burchard, Michael

    2011-09-01

    A novel diamond-anvil cell (DAC) design has been constructed and tested for in situ applications at high-pressure (HP) operations and has proved to be suitable even for HP sample environments at non-ambient temperature conditions. The innovative high-precision guiding mechanism, comparable to a dog clutch, consists of perpendicular planar sliding-plane elements and is integrated directly into the base body of the cylindrically shaped DAC. The combination of two force-generating devices, i.e., mechanical screws and an inflatable gas membrane, allows the user to choose independently between, and to apply individually, two different forcing mechanisms for pressure generation. Both mechanisms are basically independent of each other, but can also be operated simultaneously. The modularity of the DAC design allows for an easy exchange of functional core-element groups optimized not only for various analytical in situ methods but also for HP operation with or without high-temperature (HT) application. For HP-HT experiments a liquid cooling circuit inside the specific inner modular groups has been implemented to obtain a controlled and limited heat distribution within the outer DAC body.

  11. Highly efficient and concentration-insensitive organic light-emitting devices based on self-quenching-resistant orange–red iridium complex

    Energy Technology Data Exchange (ETDEWEB)

    Qi, Yige; Wang, Xu [State Key Laboratory of Electronic Thin Films and Integrated Devices, School of Optoelectronic Information, University of Electronic Science and Technology of China (UESTC), Chengdu 610054 (China); Li, Ming [College of Chemistry, Sichuan University, Chengdu 610064 (China); Lu, Zhiyun, E-mail: luzhiyun@scu.edu.cn [College of Chemistry, Sichuan University, Chengdu 610064 (China); Yu, Junsheng, E-mail: jsyu@uestc.edu.cn [State Key Laboratory of Electronic Thin Films and Integrated Devices, School of Optoelectronic Information, University of Electronic Science and Technology of China (UESTC), Chengdu 610054 (China)

    2014-11-15

    Orange–red phosphorescent organic light-emitting devices (PHOLEDs) with high efficiency and concentration insensitivity based on a novel iridium complex, bis[2-(biphenyl-4-yl)benzothiazole-N,C{sup 2}′]iridium(III) (acetylacetonate) [(4Phbt){sub 2}Ir(acac)], were fabricated. With the heavily doped emissive layer (EML) of 4,4′-N,N′-dicarbazolylbiphenyl (CBP): (4Phbt){sub 2}Ir(acac) in a wide and easily controlled dopant concentration range from 12 wt% to 24 wt%, a maximum power efficiency of 29 lm/W and an external quantum efficiency of >16% of the PHOLEDs were obtained, implying the insensitivity of electroluminescence (EL) properties to doping concentration. Meanwhile, a maximum power efficiency of 5.0 lm/W was achieved from a non-doped device with neat (4Phbt){sub 2}Ir(acac) as the EML, indicating a superior property of self-quenching resistance. The mechanism of direct exciton formation, in which exciton-formation regions are distributed throughout the EML, is responsible for the significant alleviation of triplet–triplet annihilation and superior EL performance. - Highlights: • Highly efficient and concentration-insensitive PHOLEDs were obtained. • The high efficiency of non-doped PHOLEDs indicated a quenching-resistant property. • The independence of EL spectra on doping concentration was observed. • The heavily doped devices were dominated by mechanism of direct exciton formation.

  12. Compliant Interfacial Layers in Thermoelectric Devices

    Science.gov (United States)

    Firdosy, Samad A. (Inventor); Li, Billy Chun-Yip (Inventor); Ravi, Vilupanur A. (Inventor); Fleurial, Jean-Pierre (Inventor); Caillat, Thierry (Inventor); Anjunyan, Harut (Inventor)

    2017-01-01

    A thermoelectric power generation device is disclosed using one or more mechanically compliant and thermally and electrically conductive layers at the thermoelectric material interfaces to accommodate high temperature differentials and stresses induced thereby. The compliant material may be metal foam or metal graphite composite (e.g. using nickel) and is particularly beneficial in high temperature thermoelectric generators employing Zintl thermoelectric materials. The compliant material may be disposed between the thermoelectric segments of the device or between a thermoelectric segment and the hot or cold side interconnect of the device.

  13. Medical devices and the Middle East: market, regulation, and reimbursement in Gulf Cooperation Council states

    Directory of Open Access Journals (Sweden)

    Howard JJ

    2014-11-01

    Full Text Available Jason J Howard Division of Paediatric Orthopaedics, Department of Surgery, Sidra Medical and Research Center, Doha, Qatar Abstract: With some of the richest economies in the world, the Gulf Cooperation Council (GCC is undergoing rapid growth not only in its population but also in health care expenditure. Despite the GCC's abundance of hydrocarbon-based wealth, the drivers of the medical device industry in the GCC are still in flux, with gains yet to be made in areas of infrastructure, regulation, and reimbursement. However, the regional disease burden, expanding health insurance penetration, increasing privatization, and a desire to attract skilled expatriate health care providers have led to favorable conditions for the medical device market in the GCC. The purpose of this article is to investigate the current state of the GCC medical device industry, with respect to market, regulation, and reimbursement, paying special attention to the three largest medical device markets: Saudi Arabia, the United Arab Emirates, and Qatar. The GCC would seem to represent fertile ground for the development of medical technologies, especially those in line with the regional health priorities of the respective member states. Keywords: medical devices, regulation, reimbursement, Middle East 

  14. Applications of a high temperature sessile drop device

    Energy Technology Data Exchange (ETDEWEB)

    Schwarz, B; Eisenmenger-Sittner, C [Vienna University of Technology, Insitute of Solid State Physics E-138, Wiedner Hauptstrasse 8-10, A-1040 Vienna (Austria); Worbs, P [Max-Planck-Institut fuer Plasmaphysik, Bereich Materialforschung, Boltzmannstrasse 2, D-85748 Garching (Germany)], E-mail: bernhard.schwarz@ifp.tuwien.ac.at

    2008-03-01

    The wettability of a liquid metal on a solid surface is of great technological interest for the industry (soldering, brazing, infiltration) as well as for fundamental research (diffusion, chemical reaction, intermetallic phases). The characterization of wetting is done by measuring the contact angle at the triple line of the liquid on the solid. A High Temperature Sessile Drop Device (HTSDD) was constructed and several applications were tested: (i) a wettability study of a copper-based brazing alloy (Cu-ABA) on TiN{sub x} coatings with different stoichiometries. The data derived from the HTSDD show that the reduction of the nitrogen content in the TiN coating reduces the time for reaching the final contact angle. Also for substoichiometric TiC a similar behaviour is predicted in literature. (ii) The liquid surface energy of molten metals can be estimated from the curvature of flattened droplets due to the influence of gravity. Two models were used for the calculation of the liquid surface energy of different liquid metals. (iii) From the droplet radius vs. time curves it is possible to distinguish between two different reactive wetting regimes - the diffusion and the reaction controlled reactive wetting. The beginning of this research topic will be discussed.

  15. High-performance liquid chromatography assay using ultraviolet detection for urinary quantification of milrinone concentrations in cardiac surgery patients undergoing cardiopulmonary bypass.

    Science.gov (United States)

    Gavra, Paul; Nguyen, Anne Q N; Beauregard, Natasha; Denault, André Y; Varin, France

    2014-08-01

    An analytical assay using liquid-liquid extraction and high-performance liquid chromatography with ultraviolet detection was developed for the quantification of total (conjugated and unconjugated) urinary concentrations of milrinone after the inhalation of a 5 mg dose in 15 cardiac patients undergoing cardiopulmonary bypass. Urine samples (700 μL) were extracted with ethyl-acetate and subsequently underwent acid back-extraction before and after deconjugation by mild acid hydrolysis. Milrinone was separated on a strong cation exchange analytical column. The mobile phase consisted of a constant mixture of acetonitrile:tetrahydrofurane-NaH2 PO4 buffer (40:60 v/v, pH 3.0). Thirteen calibration curves were linear in the concentration range of 31.25-4000 ng/mL, using olprinone as the internal standard (r(2) range 0.9911-0.9999, n = 13). Mean milrinone recovery and accuracy were respectively 85.2 ± 3.1% and ≥93%. Intra- and inter-day precisions (coefficients of variation) were ≤5% and ≤8%, respectively. Over a 24 h collection period, the cumulative urinary milrinone recovered from 15 patients was 26.1 ± 7.7% of the nominal 5 mg dose administered. The relative amount of milrinone glucuronic acid conjugate was negligible in the urine of patients undergoing cardiopulmonary bypass This method proved to be reliable, specific and accurate to determine the cumulative amount of total milrinone recovered in urine after inhalation. Copyright © 2014 John Wiley & Sons, Ltd.

  16. Reactor core performance calculating device

    International Nuclear Information System (INIS)

    Tominaga, Kenji; Bando, Masaru; Sano, Hiroki; Maruyama, Hiromi.

    1995-01-01

    The device of the present invention can calculate a power distribution efficiently at high speed by a plurality of calculation means while taking an amount of the reactor state into consideration. Namely, an input device takes data from a measuring device for the amount of the reactor core state such as a large number of neutron detectors disposed in the reactor core for monitoring the reactor state during operation. An input data distribution device comprises a state recognition section and a data distribution section. The state recognition section recognizes the kind and amount of the inputted data and information of the calculation means. The data distribution section analyzes the characteristic of the inputted data, divides them into a several groups, allocates them to each of the calculation means for the purpose of calculating the reactor core performance efficiently at high speed based on the information from the state recognition section. A plurality of the calculation means calculate power distribution of each of regions based on the allocated inputted data, to determine the power distribution of the entire reactor core. As a result, the reactor core can be evaluated at high accuracy and at high speed irrespective of the whole reactor core or partial region. (I.S.)

  17. Structure and application of galvanomagnetic devices

    CERN Document Server

    Weiss, H

    1969-01-01

    International Series of Monographs on Semiconductors, Volume 8: Structure and Application of Galvanomagnetic Devices focuses on the composition, reactions, transformations, and applications of galvanomagnetic devices. The book first ponders on basic physical concepts, design and fabrication of galvanomagnetic devices, and properties of galvanomagnetic devices. Discussions focus on changes in electrical properties on irradiation with high-energy particles, magnetoresistor field-plate, Hall generator, preparation of semiconductor films by vacuum deposition, structure of field-plate magnetoresist

  18. High energy density redox flow device

    Science.gov (United States)

    Chiang, Yet-Ming; Carter, William Craig; Duduta, Mihai; Limthongkul, Pimpa

    2014-05-13

    Redox flow devices are described including a positive electrode current collector, a negative electrode current collector, and an ion-permeable membrane separating said positive and negative current collectors, positioned and arranged to define a positive electroactive zone and a negative electroactive zone; wherein at least one of said positive and negative electroactive zone comprises a flowable semi-solid composition comprising ion storage compound particles capable of taking up or releasing said ions during operation of the cell, and wherein the ion storage compound particles have a polydisperse size distribution in which the finest particles present in at least 5 vol % of the total volume, is at least a factor of 5 smaller than the largest particles present in at least 5 vol % of the total volume.

  19. High-throughput deterministic single-cell encapsulation and droplet pairing, fusion, and shrinkage in a single microfluidic device

    NARCIS (Netherlands)

    Schoeman, R.M.; Kemna, Evelien; Wolbers, F.; van den Berg, Albert

    In this article, we present a microfluidic device capable of successive high-yield single-cell encapsulation in droplets, with additional droplet pairing, fusion, and shrinkage. Deterministic single-cell encapsulation is realized using Dean-coupled inertial ordering of cells in a Yin-Yang-shaped

  20. Step edge Josephson junctions and high temperature superconducting quantum interference device (SQUID) gradiometers

    International Nuclear Information System (INIS)

    Millar, Alasdair J.

    2002-01-01

    This thesis is concerned with the development of Superconducting Quantum Interference Device (SQUID) gradiometers based on the high temperature superconductor YBa 2 Cu 3 O 7-δ (YBCO). A step-edge Josephson junction fabrication process was developed to produce sufficiently steep (>60 deg) step-edges such that junctions exhibited RSJ-like current-voltage characteristics. The mean I C R N product of a sample of twenty step-edge junctions was 130μV. Step-edge dc SQUIDs with inductances between 67pH and 114pH were fabricated. Generally the SQUIDs had an intrinsic white flux noise in the 10-30μΦ 0 /√Hz range, with the best device, a 70pH SQUID, exhibiting a white flux noise of 5μΦ 0 /√Hz. Different first-order SQUID gradiometer designs were fabricated from single layers of YBCO. Two single-layer gradiometer (SLG) designs were fabricated on 10x10mm 2 substrates. The best balance and lowest gradient sensitivity measured for these devices were 1/300 and 308fT/cm√Hz (at 1 kHz) respectively. The larger baseline and larger flux capture area of the pick-up loops in a large area SLG design, fabricated on 30x10mm 2 substrates, resulted in significant improvements in the balance and gradient field sensitivity with 1/1000 and 50fT/cm√Hz (at 1kHz) measured respectively. To reduce the uniform field effective area of SLOs and therefore reduce the direct pick-up of environmental field noise when operated unshielded, a novel gradiometric SQUID (G-SQUID) device was developed. Fabricated from a single layer of YBCO, the G-SQUIDs with inductances of 67pH, had small uniform field effective areas of approximately 2μm 2 - more than two orders of magnitude smaller than the uniform field effective areas of conventional narrow linewidth SQUIDs of similar inductance. Two designs of G-SQUID were fabricated on 10x10mm 2 substrates. Due to their small effective areas, when cooled unshielded these devices showed no increase in their white flux noise. The best balance achieved for a G

  1. EXPERIMENTAL STUDIES FOR DEVELOPMENT HIGH-POWER AUDIO SPEAKER DEVICES PERFORMANCE USING PERMANENT NdFeB MAGNETS SPECIAL TECHNOLOGY

    Directory of Open Access Journals (Sweden)

    Constantin D. STĂNESCU

    2013-05-01

    Full Text Available In this paper the authors shows the research made for improving high-power audio speaker devices performance using permanent NdFeB magnets special technology. Magnetic losses inside these audio devices are due to mechanical system frictions and to thermal effect of Joules eddy currents. In this regard, by special technology, were made conical surfaces at top plate and center pin. Analysing results obtained by modelling the magnetic circuit finite element method using electronic software package,was measured increase efficiency by over 10 %, from 1,136T to13T.

  2. A method to design high SNR nanoscale magnetic sensors using an array of tunnelling magneto-resistance (TMR) devices

    International Nuclear Information System (INIS)

    Gomez, P; Litvinov, D; Khizroev, S

    2007-01-01

    This paper presents a systematic method to design and calculate tunnelling magneto-resistance (TMR) sensors with high signal-to-noise ratio (SNR). The sensing module consists of four TMR devices arranged in a Wheatstone-bridge configuration. Closed-form equations were obtained to calculate TMR sensor current, array output voltage, magneto-resistance ratio, overall noise (thermal and shot) and SNR for a given bandwidth. Using this technique we were able to maximize the SNR by tuning the many parameters of the TMR devices. Typical SNR values are in excess of 45 dB

  3. High current density M-type cathodes for vacuum electron devices

    International Nuclear Information System (INIS)

    Li Ji; Yu Zhiqiang; Shao Wensheng; Zhang Ke; Gao Yujuan; Yuan Haiqing; Wang Hui; Huang Kaizhi; Chen Qilue; Yan Suqiu; Cai Shaolun

    2005-01-01

    We investigated high current density emission capabilities of M-type cathodes used for vacuum electron devices (VEDs). The experimental results of emission and lifetime evaluating in both close-spaced diode structure and electron gun testing vehicles are given. Emission current densities measured in the diode structure at 1020 deg. C Br in the CW mode were above 10 A/cm 2 ; while in electron gun testing vehicles, emission current densities were above 8 A/cm 2 in CW mode and above 32 A/cm 2 in pulsed mode, respectively. The current density above 94 A/cm 2 has been acquired in no. 0306 electron gun vehicle while the practical temperature is 1060 deg. C Br . For a comparison some of the data from I-scandate cathodes are presented. Finally, several application examples in practical travelling wave tubes (TWTs) and multi beam klystrons (MBKs) are also reported

  4. Medical devices and the Middle East: market, regulation, and reimbursement in Gulf Cooperation Council states.

    Science.gov (United States)

    Howard, Jason J

    2014-01-01

    With some of the richest economies in the world, the Gulf Cooperation Council (GCC) is undergoing rapid growth not only in its population but also in health care expenditure. Despite the GCC's abundance of hydrocarbon-based wealth, the drivers of the medical device industry in the GCC are still in flux, with gains yet to be made in areas of infrastructure, regulation, and reimbursement. However, the regional disease burden, expanding health insurance penetration, increasing privatization, and a desire to attract skilled expatriate health care providers have led to favorable conditions for the medical device market in the GCC. The purpose of this article is to investigate the current state of the GCC medical device industry, with respect to market, regulation, and reimbursement, paying special attention to the three largest medical device markets: Saudi Arabia, the United Arab Emirates, and Qatar. The GCC would seem to represent fertile ground for the development of medical technologies, especially those in line with the regional health priorities of the respective member states.

  5. Active mems microbeam device for gas detection

    KAUST Repository

    Bouchaala, Adam M.

    2017-10-05

    Sensors and active switches for applications in gas detection and other fields are described. The devices are based on the softening and hardening nonlinear response behaviors of microelectromechanical systems (MEMS) clamped-clamped microbeams. In that context, embodiments of gas-triggered MEMS microbeam sensors and switches are described. The microbeam devices can be coated with a Metal-Organic Framework to achieve high sensitivity. For gas sensing, an amplitude-based tracking algorithm can be used to quantify an amount of gas captured by the devices according to frequency shift. Noise analysis is also conducted according to the embodiments, which shows that the microbeam devices have high stability against thermal noise. The microbeam devices are also suitable for the generation of binary sensing information for alarming, for example.

  6. Turbocharged molecular discovery of OLED emitters: from high-throughput quantum simulation to highly efficient TADF devices

    Science.gov (United States)

    Gómez-Bombarelli, Rafael; Aguilera-Iparraguirre, Jorge; Hirzel, Timothy D.; Ha, Dong-Gwang; Einzinger, Markus; Wu, Tony; Baldo, Marc A.; Aspuru-Guzik, Alán.

    2016-09-01

    Discovering new OLED emitters requires many experiments to synthesize candidates and test performance in devices. Large scale computer simulation can greatly speed this search process but the problem remains challenging enough that brute force application of massive computing power is not enough to successfully identify novel structures. We report a successful High Throughput Virtual Screening study that leveraged a range of methods to optimize the search process. The generation of candidate structures was constrained to contain combinatorial explosion. Simulations were tuned to the specific problem and calibrated with experimental results. Experimentalists and theorists actively collaborated such that experimental feedback was regularly utilized to update and shape the computational search. Supervised machine learning methods prioritized candidate structures prior to quantum chemistry simulation to prevent wasting compute on likely poor performers. With this combination of techniques, each multiplying the strength of the search, this effort managed to navigate an area of molecular space and identify hundreds of promising OLED candidate structures. An experimentally validated selection of this set shows emitters with external quantum efficiencies as high as 22%.

  7. Low Damage, High Anisotropy Inductively Coupled Plasma for Gallium Nitride based Devices

    KAUST Repository

    Ibrahim, Youssef H.

    2013-01-01

    . The processing requirements for laser devices and ridge waveguides are stringent as compared to LEDs and other electronic devices. Due to the strong bonding and chemically inert nature of GaN, dry etching becomes a critical fabrication step. The surface

  8. Rf superconducting devices

    International Nuclear Information System (INIS)

    Hartwig, W.H.; Passow, C.

    1975-01-01

    Topics discussed include (1) the theory of superconductors in high-frequency fields (London surface impedance, anomalous normal surface resistance, pippard nonlocal theory, quantum mechanical model, superconductor parameters, quantum mechanical calculation techniques for the surface, impedance, and experimental verification of surface impedance theories); (2) residual resistance (separation of losses, magnetic field effects, surface resistance of imperfect and impure conductors, residual loss due to acoustic coupling, losses from nonideal surfaces, high magnetic field losses, field emission, and nonlinear effects); (3) design and performance of superconducting devices (design considerations, materials and fabrication techniques, measurement of performance, and frequency stability); (4) devices for particle acceleration and deflection (advantages and problems of using superconductors, accelerators for fast particles, accelerators for particles with slow velocities, beam optical devices separators, and applications and projects under way); (5) applications of low-power superconducting resonators (superconducting filters and tuners, oscillators and detectors, mixers and amplifiers, antennas and output tanks, superconducting resonators for materials research, and radiation detection with loaded superconducting resonators); and (6) transmission and delay lines

  9. Architectures for Improved Organic Semiconductor Devices

    Science.gov (United States)

    Beck, Jonathan H.

    Advancements in the microelectronics industry have brought increasing performance and decreasing prices to a wide range of users. Conventional silicon-based electronics have followed Moore's law to provide an ever-increasing integrated circuit transistor density, which drives processing power, solid-state memory density, and sensor technologies. As shrinking conventional integrated circuits became more challenging, researchers began exploring electronics with the potential to penetrate new applications with a low price of entry: "Electronics everywhere." The new generation of electronics is thin, light, flexible, and inexpensive. Organic electronics are part of the new generation of thin-film electronics, relying on the synthetic flexibility of carbon molecules to create organic semiconductors, absorbers, and emitters which perform useful tasks. Organic electronics can be fabricated with low energy input on a variety of novel substrates, including inexpensive plastic sheets. The potential ease of synthesis and fabrication of organic-based devices means that organic electronics can be made at very low cost. Successfully demonstrated organic semiconductor devices include photovoltaics, photodetectors, transistors, and light emitting diodes. Several challenges that face organic semiconductor devices are low performance relative to conventional devices, long-term device stability, and development of new organic-compatible processes and materials. While the absorption and emission performance of organic materials in photovoltaics and light emitting diodes is extraordinarily high for thin films, the charge conduction mobilities are generally low. Building highly efficient devices with low-mobility materials is one challenge. Many organic semiconductor films are unstable during fabrication, storage, and operation due to reactions with water, oxygen and hydroxide. A final challenge facing organic electronics is the need for new processes and materials for electrodes

  10. Short and long term ionizing radiation effects on charge-coupled devices in radiation environment of high-intensity heavy ion accelerators

    International Nuclear Information System (INIS)

    Belousov, A; Mustafin, E; Ensinger, W

    2012-01-01

    Radiation effects on semiconductor devices is a topical issue for high-intensity accelerator projects. In particular it concerns Charge-Coupled Device (CCD) cameras, which are widely used for beam profile monitoring and surveillance in high radiation environment. One should have a clear idea of short and long term radiation effects on such devices. To study these effects, a CCD camera was placed in positions less than half meter away from beam loss point. Primary heavy ion beam of 0.95GeV/n Uranium was dumped into a thick aluminium target creating high fluences of secondary particles (e.g., gammas, neutrons, protons). Effects of these particles on CCD camera were scored with LabView based acquisition software. Monte Carlo calculations with FLUKA code were performed to obtain fluence distributions for different particles and make relevant comparisons. Long term total ionising dose effects are represented by dark current increase, which was scored throughout experiment. Instant radiation effects are represented by creation of charge in CCD cells by ionising particles. Relation of this charge to beam intensity was obtained for different camera positions and fluences within 5 orders of magnitude ranges. With high intensities this charge is so high that it may dramatically influence data obtained from CCD camera used in high radiation environment. The linearity of described above relation confirms linear response of CCD to ionizing radiation. It gives an opportunity to find a new application to CCD cameras as beam loss monitors (BLM).

  11. High Altitude Electromagnetic Pulse (HEMP) and High Power Microwave (HPM) Devices: Threat Assessments

    National Research Council Canada - National Science Library

    Wilson, Clay

    2004-01-01

    .... civilian computer systems to the effects of EMP has been discussed in the media. EMP can be produced on a large scale using a single nuclear explosion, and on a smaller, non-nuclear scale using a device with batteries or chemical explosives...

  12. Risk of contrast-medium-induced nephropathy in high-risk patients undergoing MDCT - A pooled analysis of two randomized trials

    Energy Technology Data Exchange (ETDEWEB)

    Thomsen, Henrik S. [University of Copenhagen, Department of Diagnostic Radiology, Copenhagen University Hospital Herlev, and Department of Diagnostic Sciences, Faculty of Health Sciences, Herlev (Denmark); Morcos, Sameh K. [University of Sheffield, Department of Diagnostic Imaging, Northern General Hospital, Sheffield (United Kingdom)

    2009-04-15

    The incidence of contrast-medium-induced nephropathy (CIN) following intravenous (IV) CM administration of contrast media to renally impaired patients undergoing multidetector computed tomography (MDCT) is not well characterized. Our objective was to investigate the incidence of CIN in patients with glomerular filtration rate (GFR) <60 ml/min undergoing contrast-enhanced MDCT examinations and to compare the rates of CIN following the IV administration of low-osmolar contrast media (LOCM, iopamidol and iomeprol) and an iso-osmolar contrast medium (IOCM, iodixanol). A total of 301 adult patients with moderate-to-severe renal failure received a similar IV contrast dose (40 gI). Serum creatinine (SCr) was measured at screening, baseline and 48-72 {+-} 6 h after the MDCT examination. Primary CIN outcome was an increase in SCr {>=}0.5 mg/dl ({>=}44.2 {mu}mol/l) from baseline. The CIN rates were 2.3% in the total population, 0.6% when GFR >40 ml/min, 4.6% when GFR <40 ml/min and 7.8% in patients with GFR <30 ml/min. The incidence of CIN was significantly higher after iodixanol than after LOCM (seven patients, 4.7% following IOCM, no CIN cases following the LOCM; p = 0.007). Significant differences in favor of the LOCM were also observed in patients with GFR <40 ml/min and GFR <30 ml/min. Following the IV administration of nonionic contrast agents in patients with moderate-to-severe renal insufficiency, the risk of significant CIN seems to be low. The IOCM iodixanol caused a higher rate of CIN than the LOCM iopamidol and iomeprol, especially in high-risk patients. Differences in osmolality between these LOCM and iodixanol do not play a role in the genesis of CIN. (orig.)

  13. Dust in fusion devices-a multi-faceted problem connecting high- and low-temperature plasma physics

    International Nuclear Information System (INIS)

    Winter, J

    2004-01-01

    Small particles with sizes between a few nanometers and a few 10 μm (dust) are formed in fusion devices by plasma-surface interaction processes. Though it is not a major problem today, dust is considered a problem that could arise in future long pulse fusion devices. This is primarily due to its radioactivity and due to its very high chemical reactivity. Dust formation is particularly pronounced when carbonaceous wall materials are used. Dust particles can be transported in the tokamak over significant distances. Radioactivity leads to electrical charging of dust and to its interaction with plasmas and electric fields. This may cause interference with the discharge but may also result in options for particle removal. This paper discusses some of the multi-faceted problems using information both from fusion research and from low-temperature dusty plasma work

  14. Electron-transporting layer doped with cesium azide for high-performance phosphorescent and tandem white organic light-emitting devices

    Science.gov (United States)

    Yu, Yaoyao; Chen, Xingming; Jin, Yu; Wu, Zhijun; Yu, Ye; Lin, Wenyan; Yang, Huishan

    2017-07-01

    Cesium azide was employed as an effective n-dopant in the electron-transporting layer (ETL) of organic light-emitting devices (OLEDs) owing to its low deposition temperature and high ambient stability. By doping cesium azide onto 4,7-diphenyl-1,10-phenanthroline, a green phosphorescent OLED having best efficiencies of 66.25 cd A-1, 81.22 lm W-1 and 18.82% was realized. Moreover, the efficiency roll-off from 1000 cd m-2 to 10 000 cd m-2 is only 12.9%, which is comparable with or even lower than that of devices utilizing the co-host system. Physical mechanisms for the improvement of device performance were studied in depth by analyzing the current density-voltage (J-V) characteristics of the electron-only devices. In particular, by comparing the J-V characteristics of the electron-only devices instead of applying the complicated ultraviolet photoelectron spectrometer measurements, we deduced the decrease in barrier height for electron injection at the ETL/cathode contact. Finally, an efficient tandem white OLED utilizing the n-doped layer in the charge generation unit (CGU) was constructed. As far as we know, this is the first report on the application of this CGU for fabricating tandem white OLEDs. The emissions of the tandem device are all in the warm white region from 1213 cd m-2 to 10870 cd m-2, as is beneficial to the lighting application.

  15. Electron-transporting layer doped with cesium azide for high-performance phosphorescent and tandem white organic light-emitting devices

    International Nuclear Information System (INIS)

    Yu, Yaoyao; Chen, Xingming; Jin, Yu; Wu, Zhijun; Yu, Ye; Lin, Wenyan; Yang, Huishan

    2017-01-01

    Cesium azide was employed as an effective n-dopant in the electron-transporting layer (ETL) of organic light-emitting devices (OLEDs) owing to its low deposition temperature and high ambient stability. By doping cesium azide onto 4,7-diphenyl-1,10-phenanthroline, a green phosphorescent OLED having best efficiencies of 66.25 cd A −1 , 81.22 lm W −1 and 18.82% was realized. Moreover, the efficiency roll-off from 1000 cd m −2 to 10 000 cd m −2 is only 12.9%, which is comparable with or even lower than that of devices utilizing the co-host system. Physical mechanisms for the improvement of device performance were studied in depth by analyzing the current density–voltage ( J – V ) characteristics of the electron-only devices. In particular, by comparing the J – V characteristics of the electron-only devices instead of applying the complicated ultraviolet photoelectron spectrometer measurements, we deduced the decrease in barrier height for electron injection at the ETL/cathode contact. Finally, an efficient tandem white OLED utilizing the n-doped layer in the charge generation unit (CGU) was constructed. As far as we know, this is the first report on the application of this CGU for fabricating tandem white OLEDs. The emissions of the tandem device are all in the warm white region from 1213 cd m −2 to 10870 cd m −2 , as is beneficial to the lighting application. (paper)

  16. Fabrication and characterization of an integrated ionic device from suspended polypyrrole and alamethicin-reconstituted lipid bilayer membranes

    International Nuclear Information System (INIS)

    Northcutt, Robert; Sundaresan, Vishnu-Baba

    2012-01-01

    Conducting polymers are electroactive materials that undergo conformal relaxation of the polymer backbone in the presence of an electrical field through ion exchange with solid or aqueous electrolytes. This conformal relaxation and the associated morphological changes make conducting polymers highly suitable for actuation and sensing applications. Among smart materials, bioderived active materials also use ion transport for sensing and actuation functions via selective ion transport. The transporter proteins extracted from biological cell membranes and reconstituted into a bilayer lipid membrane in bioderived active materials regulate ion transport for engineering functions. The protein transporter reconstituted in the bilayer lipid membrane is referred to as the bioderived membrane and serves as the active component in bioderived active materials. Inspired by the similarities in the physics of transduction in conducting polymers and bioderived active materials, an integrated ionic device is formed from the bioderived membrane and the conducting polymer membrane. This ionic device is fabricated into a laminated thin-film membrane and a common ion that can be processed by the bioderived and the conducting polymer membranes couple the ionic function of these two membranes. An integrated ionic device, fabricated from polypyrrole (PPy) doped with sodium dodecylbenzenesulfonate (NaDBS) and an alamethicin-reconstituted DPhPC bilayer lipid membrane, is presented in this paper. A voltage-gated sodium current regulates the electrochemical response in the PPy(DBS) layer. The integrated device is fabricated on silicon-based substrates through microfabrication, electropolymerization, and vesicle fusion, and ionic activity is characterized through electrochemical measurements. (paper)

  17. High performance flexible electronics for biomedical devices.

    Science.gov (United States)

    Salvatore, Giovanni A; Munzenrieder, Niko; Zysset, Christoph; Kinkeldei, Thomas; Petti, Luisa; Troster, Gerhard

    2014-01-01

    Plastic electronics is soft, deformable and lightweight and it is suitable for the realization of devices which can form an intimate interface with the body, be implanted or integrated into textile for wearable and biomedical applications. Here, we present flexible electronics based on amorphous oxide semiconductors (a-IGZO) whose performance can achieve MHz frequency even when bent around hair. We developed an assembly technique to integrate complex electronic functionalities into textile while preserving the softness of the garment. All this and further developments can open up new opportunities in health monitoring, biotechnology and telemedicine.

  18. Energy storage device with large charge separation

    Science.gov (United States)

    Holme, Timothy P.; Prinz, Friedrich B.; Iancu, Andrei T.

    2018-04-03

    High density energy storage in semiconductor devices is provided. There are two main aspects of the present approach. The first aspect is to provide high density energy storage in semiconductor devices based on formation of a plasma in the semiconductor. The second aspect is to provide high density energy storage based on charge separation in a p-n junction.

  19. Sample taking device for toxic and/or radioactive substances

    International Nuclear Information System (INIS)

    Finsterwalder, L.; Zeh, H.; Schaarschmidt, U.

    1979-01-01

    An apparatus for taking samples of toxic and/or radioactive liquid substances by introducing such substances into sample vessels includes a holder for holding such a vessel, at least one needle head filling system composed of upwardly pointing hollow needles for introducing a sample of one such substance into such a vessel at a filling position, and inlet and outlet conduits for pneumatically conveying vessels to or from the holder at a transfer position. The holder is composed of a turntable having a sleeve for accommodating such vessel and is mounted to undergo rotary movement to convey a sample vessel held in the sleeve between the filling and transfer positions. The apparatus further includes a stand supporting the filling system below the holder and a lifting device connected for imparting a translational movement to the holder to bring a vessel in the holder to operative association with the filling system. The lifting device is arranged so that the translational movement which it produces is independent of the rotary movement of the turntable

  20. Factors Associated With Work Ability in Patients Undergoing Surgery for Cervical Radiculopathy.

    Science.gov (United States)

    Ng, Eunice; Johnston, Venerina; Wibault, Johanna; Löfgren, Håkan; Dedering, Åsa; Öberg, Birgitta; Zsigmond, Peter; Peolsson, Anneli

    2015-08-15

    Cross-sectional study. To investigate the factors associated with work ability in patients undergoing surgery for cervical radiculopathy. Surgery is a common treatment of cervical radiculopathy in people of working age. However, few studies have investigated the impact on the work ability of these patients. Patients undergoing surgery for cervical radiculopathy (n = 201) were recruited from spine centers in Sweden to complete a battery of questionnaires and physical measures the day before surgery. The associations between various individual, psychological, and work-related factors and self-reported work ability were investigated by Spearman rank correlation coefficient, multivariate linear regression, and forward stepwise regression analyses. Factors that were significant (P work ability. Work ability was assessed using the Work Ability Index. The mean Work Ability Index score was 28 (SD, 9.0). The forward stepwise regression analysis revealed 6 factors significantly associated with work ability, which explained 62% of the variance in the Work Ability Index. Factors highly correlated with greater work ability included greater self-efficacy in performing self-cares, lower physical load on the neck at work, greater self-reported chance of being able to work in 6 months' time, greater use of active coping strategies, lower frequency of hand weakness, and higher health-related quality of life. Psychological, work-related and individual factors were significantly associated with work ability in patients undergoing surgery for cervical radiculopathy. High self-efficacy was most associated with greater work ability. Consideration of these factors by surgeons preoperatively may provide optimal return to work outcomes after surgery. 3.