WorldWideScience

Sample records for devices experimental results

  1. Integrated visualization of simulation results and experimental devices in virtual-reality space

    International Nuclear Information System (INIS)

    Ohtani, Hiroaki; Ishiguro, Seiji; Shohji, Mamoru; Kageyama, Akira; Tamura, Yuichi

    2011-01-01

    We succeeded in integrating the visualization of both simulation results and experimental device data in virtual-reality (VR) space using CAVE system. Simulation results are shown using Virtual LHD software, which can show magnetic field line, particle trajectory, and isosurface of plasma pressure of the Large Helical Device (LHD) based on data from the magnetohydrodynamics equilibrium simulation. A three-dimensional mouse, or wand, determines the initial position and pitch angle of a drift particle or the starting point of a magnetic field line, interactively in the VR space. The trajectory of a particle and the stream-line of magnetic field are calculated using the Runge-Kutta-Huta integration method on the basis of the results obtained after pointing the initial condition. The LHD vessel is objectively visualized based on CAD-data. By using these results and data, the simulated LHD plasma can be interactively drawn in the objective description of the LHD experimental vessel. Through this integrated visualization, it is possible to grasp the three-dimensional relationship of the positions between the device and plasma in the VR space, opening a new path in contribution to future research. (author)

  2. The ''ATOS'' experimental device

    International Nuclear Information System (INIS)

    Belyaev, V.A.; Dorovskij, A.P.; Dubrovin, M.M.; Khlopkin, A.N.

    1980-08-01

    This paper contains a brief description of the ATOS experimental device at the I.V. Kurchatov Institute, Moscow, USSR, which has been designed in accordance with the merged beam principle to investigate collisions between heavy atomic particles and multiply-charged ions of impurity elements - following the programme of the Joint IFRC/INDC Subcommittee on Atomic and Molecular Data for Fusion

  3. Test results of the experimental laser device for potato tubers radiation treatment

    International Nuclear Information System (INIS)

    Anufrik, S.S.; Korzun, O.S.

    2007-01-01

    Results of 3 year investigation of the influence of the presowing low intensity laser radiation treatment of potato (Solanum tuberosum L.) tubers with the help of laser device with various spectral composition and exposition on plant growth, development and productivity and potato tubers quality and starch content in the conditions of the Republic of Belarus were presented. Presowing tubers treatment of potato cultivars Sante, Yavar and Arkhideya was realized by He-Ne, Ar-, Cu (in course of 3 and 5 minutes) and CO2 (in course of 5 seconds) lasers. Research results have shown that presowing treatment with CO2 laser promoted the higher (on 1,7-6,6%) potato germination capacity in comparison with the control variant without radiation treatment. Height of potato plants of Sante variety after radiation treatment fell behind the control ones. Haulm quantity per one plant and yield quality did not depend on radiation treatment Treatment with CO2 laser exercised the stimulatory action on productivity of Sante variety without changing the starch content in tubers. Tuber weight increased up to 0,4 kg (0,2 kg in the control variant). Similar effect for Arkhideya and Yavar varieties was obtained after Cu-laser treatment in course of 5 minutes. Radiation treatment with He-Ne laser caused the increased starch accumulation (on 0,4-0,6% in comparison with the control variant) in potato tubers of all studied varieties

  4. Experimental Results on a Wireless Wattmeter Device for the Integration in Home Energy Management Systems

    Directory of Open Access Journals (Sweden)

    Eduardo M. G. Rodrigues

    2017-03-01

    Full Text Available This paper presents a home area network (HAN-based domestic load energy consumption monitoring prototype device as part of an advanced metering system (AMS. This device can be placed on individual loads or configured to measure several loads as a whole. The wireless communication infrastructure is supported on IEEE 805.12.04 radios that run a ZigBee stack. Data acquisition concerning load energy transit is processed in real time and the main electrical parameters are then transmitted through a RF link to a wireless terminal unit, which works as a data logger and as a human-machine interface. Voltage and current sensing are implemented using Hall effect principle-based transducers, while C code is developed on two 16/32-bit microcontroller units (MCUs. The main features and design options are then thoroughly discussed. The main contribution of this paper is that the proposed metering system measures the reactive energy component through the Hilbert transform for low cost measuring device systems.

  5. A new self-firing MOS-thyristor device: optimization of the turn-off performance and experimental results

    Energy Technology Data Exchange (ETDEWEB)

    Breil, M.; Sanchez, J.L.; Austin, P.; Laur, J.P.

    1998-12-01

    In this paper, a new integrated self-firing and controlled turn-off MOS-thyristor structure is investigated. An analytical model describing the turn-off operation and parasitic latch-up has been developed, allowing to highlight and optimize the physical and geometrical parameters acting upon main electrical characteristics. The analytical model is validated by 2D simulations using PISCES. The technological fabrication process is optimized by 2D simulations using SUPREM IV. Electrical characterization results of fabricated test structures are presented. (authors) 6 refs.

  6. New particles: experimental results

    International Nuclear Information System (INIS)

    Augustin, J.E.

    The results of studies on production and properties of psi(3100) and psi(3700) resonances are presented, particular attention being given to spin, parity, g-parity and isospin determination. Evidence obtained in the SPEAR and DORIS storage rings in psi'→γ chi and psi→γX intermediate states are presented, together with SPEAR results on e-μ events and high energy jet production. (39 references) [fr

  7. Plan Merging : Experimental results

    NARCIS (Netherlands)

    De Weerdt, M.M.; Van der Krogt, R.P.J.; Zutt, J.

    2003-01-01

    In this paper we discuss the results of a plan merging algorithm. This algorithm coordinates the plans of multiple, autonomous agents, each able to independently find a plan. This algorithm is evaluated using realistic data from a taxi company. We show that when we allow passengers to be a few

  8. Experimental results from Stripa

    International Nuclear Information System (INIS)

    Hood, M.

    1979-06-01

    The results indicate that the temperature fields in a rock mass containing geologic discontinuities can be predicted accurately using the simple theory of heat conduction. Geologic discontinuities appear to introduce significant nonlinear thermomechanical deformation into the rock mass, as a result of which the thermally induced displacements are much less than those predicted by the simple theory of thermo-elasticity. In addition, the assumption that the rock properties are temperature independent appears to increase the values predicted for these displacements significantly. Therefore, it is important that the temperature dependence of these properties is known and that these values be used in the calculations. The onset of significant thermal spalling along the walls of the heater boreholes appears to be related to conditions where the maximum induced compressive stress exceeds the uniaxial compressive strength of the rock. 7 figures

  9. PDX experimental results

    International Nuclear Information System (INIS)

    Meade, D.; Arunasalam, V.; Barnes, C.

    1981-01-01

    During the initial period of operation PDX has obtained the following results: (a) Production of macroscopically stable poloidal divertor configurations with dee, inverse-dee and single null plasma shapes. (b) Determined vertical positional instability growth rates for passively stabilized elongated dee-shaped plasmas with surface elongations from 1 to 1.4. (c) Production of Z approximately equal to 1 plasmas in a diverted dee configuration with confinement times approaching 80 ms for plasmas with Isub(p) approximately equal to 300 kA, Bsub(T)=17 kG, a=38 cm, q approximately equal to 3 and anti nsub(e) approximately equal to 4x10 13 cm -3 . (d) Extended the Ohmic heating regime to q approximately equal to 2 at nsub(e)R/Bsub(T) approximately equal to 10 15 cm -2 T -1 and q approximately equal to 3 at anti nsub(e)R/Bsub(T) approximately equal to 4.5x10 15 cm -2 T -1 . Neutral beam injection has extended anti nsub(e)R/Bsub(T) to approximately 6x10 15 cm -2 T -1 . (e) Initial neutral beam injection experiments with 1-2 MW injected perpendicularly have been used to study ion and electron heating with divertor control of density and impurities. (f) Divertor physics studies indicate that the divertor captures approximately 70% of the input power, while approximately 30% of the power is radiated. (g) Particle and energy flow onto the divertor neutralizer plate is in qualitative agreement with a simple sheath model. (author)

  10. Experimental lysimetric device NPP A-1

    International Nuclear Information System (INIS)

    Matusek, I.; Plsko, J.

    2002-01-01

    In the frame of decommissioning of the NPP A-1 in the locality Jaslovske Bohunice the problem of remedial measures in scope of radioactive contaminated soils is also studied. These soils have originated in the area of the NPP A-1 by different mechanisms as the result of leakages from technology and in the present time they represent the secondary source of contamination of underground waters. Contaminated soils represent the particularity, because we can characterize them as voluminous radioactive contaminated residues with low-level or very low-level activity. EKOSUR Company in the frame of active underground water protection suggested more remedial measures. Two basic tasks are solved in the field of the contaminated soils: rehabilitation of contaminated soils or temporary immobilisation of radionuclides in the contaminated volumes, deposition of rehabilitated soils in the storage of landfill type. In the frame of engineering solution of the landfill storage the question of technology of own deposition of contaminated soils into storage area is important from the safety viewpoint. Therefore the Experimental lysimetric device was built for half-operational test of suggested technologies. This device contains 6 pieces of lysimeters with 6 active volumes of approximately 1 cubic meter. The aim of suggested and in the present time realised experiments is the practical modelling of influence of filtering of waters into storage of contaminated soils in configurational and qualitative different conditions of deposition of soils (for example exploitation of sorption materials). Also the structure of un-rehabilitated soils by the influence of natural downfalls activity is modelled in one lysimeter. In this issue the authors deal with the construction of lysimetric device, proposed experiments as like as gained results of observations. (authors)

  11. Experimental Measurement-Device-Independent Entanglement Detection

    Science.gov (United States)

    Nawareg, Mohamed; Muhammad, Sadiq; Amselem, Elias; Bourennane, Mohamed

    2015-02-01

    Entanglement is one of the most puzzling features of quantum theory and of great importance for the new field of quantum information. The determination whether a given state is entangled or not is one of the most challenging open problems of the field. Here we report on the experimental demonstration of measurement-device-independent (MDI) entanglement detection using witness method for general two qubits photon polarization systems. In the MDI settings, there is no requirement to assume perfect implementations or neither to trust the measurement devices. This experimental demonstration can be generalized for the investigation of properties of quantum systems and for the realization of cryptography and communication protocols.

  12. Experimental results obtained at GANIL

    International Nuclear Information System (INIS)

    Borrel, V.

    1993-01-01

    A review of experimental results obtained at GANIL on the study of nuclear structure and nuclear reactions with secondary radioactive beams is presented. Mass measurements by means of the GANIL cyclotrons are described. The possibilities of GANIL/LISE3 for the production and separation of radioactive beams are illustrated through a large variety of experiments. (author). 19 refs., 8 figs

  13. A Cs-137 afterloading device. Preliminary results of cell kinetic effects of low dose-rate irradiation in an experimental tumour

    International Nuclear Information System (INIS)

    Rutgers, D.H.

    1988-01-01

    A Cs-137 afterloading technique is described which can be used in experimental tumours. Preliminary results, obtained with the human cervical carcinoma ME-180 xenografted to nude athymic mice, demonstrated that 20 Gy of low dose-rate irradiation induced an important redistribution of cells over cell cycle. The proportion of cells in G2-phase increased from 14.4% to 44.2% at 140 hours after irradiation. This method allows an accurate calculation of the dose-rate distribution in the tumour. Investigations of the cell kinetic effects of low dose-rate irradiation, at different dose-rates and different total doses, are therefore facilitated by the technique. (orig.) [de

  14. The Bigfoot Drive; Experimental Results

    Science.gov (United States)

    Baker, Kevin; Thomas, Cliff; Khan, Shahab; Casey, Daniel; Spears, Brian; Nora, Ryan; Munro, Davis; Eder, David; Milovich, Jose; Berger, Dick; Strozzi, David; Goyon, Clement; Turnbull, David; Ma, Tammy; Izumi, Nobuhiko; Benedetti, Robin; Millot, Marius; Celliers, Peter; Yeamans, Charles; Hatarik, Robert; Landen, Nino; Hurricane, Omar; Callahan, Debbie

    2016-10-01

    The Bigfoot platform was developed on the National Ignition Facility to investigate low convergence, high adiabat, high rhoR hotspot implosions. This platform was designed to be less susceptible to wall motion, LPI and CBET and to be more robust against capsule hydrodynamic instabilities. To date experimental studies have been carried out at two hohlraum scales, a 5.75 and 5.4 mm diameter hohlraum. We will present experimental results from these tuning campaigns including the shape vs. cone fraction, surrogacy comparisons of self-emission from the capsules vs. radiography of the imploding capsule and doped vs. undoped capsules. Prepared by LLNL under Contract DE-AC52-07NA27344.

  15. Experimental results on evaporation waves

    Science.gov (United States)

    Grana Otero, Jose; Parra Fabian, Ignacio

    2010-11-01

    A liquid contained in a vertical glass tube is suddenly depressurized from a high initial pressure down to one for which the stable state is vapour, so vaporization sets off at the free surface. For large enough evaporation rates, the planar vapour-liquid interface is Darrieus-Landau unstable [1], leading to the interface surface rippling close to the instability threshold. Further increasing the initial to final pressure ratio brings about evaporation waves [2,3], in which a highly corrugated front propagates downwards into the liquid. A new experimental method is presented as well as some experimental results obtained by tracking the evolution of the front with a high speed camera. In addition, a number of new phenomena related to the dynamics of bubbles growth at the walls has been uncovered. In particular, a new mode of propagation of the evaporation front is found. In this mode the front originates from below the interface, so the propagation is upwards against gravity with a curved but smooth front.[4pt] [1] F. J. Higuera, Phys. Fluids, V. 30, 679 (1987).[0pt] [2] J.E.Shepherd and B.Sturtevant, J.Fluid Mech., V.121,379 (1982).[0pt] [3] P.Reinke and G.Yadigaroglu, Int.J.Multiph. Flow, V.27,1487 (2001).

  16. Research on condensed matter and atomic physics using major experimental facilities and devices: Physics, chemistry, biology. Reports on results. Vol. 2. 3. Solid state physics and materials science

    International Nuclear Information System (INIS)

    1993-01-01

    This report in three volumes substantiates the contents of the programme survey published in September 1989. The progress reports cover the following research areas: Vol. I, (1). Atomic and molecular physics - free atoms, molecules, macromolecules, clusters, matrix-isolated atoms and molecules. (2) Physics and chemistry of surfaces and interfaces - epitaxy, surface structure, adsorption, electrical, magnetic, and optical properties, thin films, synthetic layer structure. Vol. II, (3). Solid-state physics, and materials science -structural research, lattice dynamics, magnetic structure and dynamics, electronic states; load; spin and pulse density fluctuations; diffusion and internal motion, defects, unordered systems and liquids. Vol. III, (4). Chemistry - bonding and structure, kinetics and reaction mechanisms, polymer research, analysis and synthesis. (5). Biology, - structure and dynamics of biological macromolecules, membrane and cell biology. (6) Development of methods and instruments - neutron sources, synchrotron sources, special accelerators, research with interlinked systems and devices. (orig.) [de

  17. Experimental study of glass sampling devices

    International Nuclear Information System (INIS)

    Jouan, A.; Moncouyoux, J.P.; Meyere, A.

    1992-01-01

    Two high-level liquid waste containment glass sampling systems have been designed and built. The first device fits entirely inside a standard glass storage canister, and may thus be used in facilities not initially designed for this function. It has been tested successfully in the nonradioactive prototype unit at Marcoule. The work primarily covered the design and construction of an articulated arm supporting the sampling vessel, and the mechanisms necessary for filling the vessel and recovering the sample. System actuation and operation are fully automatic, and the resulting sample is representative of the glass melt. Implementation of the device is delicate however, and its reliability is estimated at about 75%. A second device was designed specifically for new vitrification facilities. It is installed directly on the glass melting furnace, and meets process operating and quality control requirements. Tests conducted at the Marcoule prototype vitrification facility demonstrated the feasibility of the system. Special attention was given to the sampling vessel transfer mechanisms, with two filling and controlled sample cooling options

  18. Majorana Thermosyphon Prototype Experimental Results

    International Nuclear Information System (INIS)

    Fast, James E.; Reid, Douglas J.; Aguayo Navarrete, Estanislao

    2010-01-01

    The Majorana demonstrator will operate at liquid Nitrogen temperatures to ensure optimal spectrometric performance of its High Purity Germanium (HPGe) detector modules. In order to transfer the heat load of the detector module, the Majorana demonstrator requires a cooling system that will maintain a stable liquid nitrogen temperature. This cooling system is required to transport the heat from the detector chamber outside the shield. One approach is to use the two phase liquid-gas equilibrium to ensure constant temperature. This cooling technique is used in a thermosyphon. The thermosyphon can be designed so the vaporization/condensing process transfers heat through the shield while maintaining a stable operating temperature. A prototype of such system has been built at PNNL. This document presents the experimental results of the prototype and evaluates the heat transfer performance of the system. The cool down time, temperature gradient in the thermosyphon, and heat transfer analysis are studied in this document with different heat load applied to the prototype.

  19. Experimental Study of a Multi Level Overtopping Wave Power Device

    DEFF Research Database (Denmark)

    Kofoed, Jens Peter; Hald, Tue; Frigaard, Peter Bak

    2002-01-01

    Results of experimental investigations of a floating wave energy device called Power Pyramid is presented. The Power Pyramid utilizes reservoirs in multiple levels when capturing wave overtopping and converting it into electrical energy. The effect of capturing the overtopping in multiple levels,......, using 5 levels introduces practical problems, and is most probably not economically feasible. It is concluded that it is reasonable to use 2 levels (maybe 3), which can increase the efficiency by 25-40 % compared to using a single level.......Results of experimental investigations of a floating wave energy device called Power Pyramid is presented. The Power Pyramid utilizes reservoirs in multiple levels when capturing wave overtopping and converting it into electrical energy. The effect of capturing the overtopping in multiple levels......, compared to only one level, has been evaluated experimentally. From the experimental results, and the performed optimizations based on these, it has been found that the efficiency of a wave power device of the overtopping type can be increased by as much as 76 % by using 5 levels instead of 1. However...

  20. Design and experimentation of BSFQ logic devices

    International Nuclear Information System (INIS)

    Hosoki, T.; Kodaka, H.; Kitagawa, M.; Okabe, Y.

    1999-01-01

    Rapid single flux quantum (RSFQ) logic needs synchronous pulses for each gate, so the clock-wiring problem is more serious when designing larger scale circuits with this logic. So we have proposed a new SFQ logic which follows Boolean algebra perfectly by using set and reset pulses. With this logic, the level information of current input is transmitted with these pulses generated by level-to-pulse converters, and each gate calculates logic using its phase level made by these pulses. Therefore, our logic needs no clock in each gate. We called this logic 'Boolean SFQ (BSFQ) logic'. In this paper, we report design and experimentation for an AND gate with inverting input based on BSFQ logic. The experimental results for OR and XOR gates are also reported. (author)

  1. Experimental and analytical study on thermoelectric self cooling of devices

    International Nuclear Information System (INIS)

    Martinez, A.; Astrain, D.; Rodriguez, A.

    2011-01-01

    This paper presents and studies the novel concept of thermoelectric self cooling, which can be introduced as the cooling and temperature control of a device using thermoelectric technology without electricity consumption. For this study, it is designed a device endowed with an internal heat source. Subsequently, a commonly used cooling system is attached to the device and the thermal performance is statistically assessed. Afterwards, it is developed and studied a thermoelectric self cooling system appropriate for the device. Experimental and analytical results show that the thermal resistance between the heat source and the environment reduced by 25-30% when the thermoelectric self cooling system is installed, and indicates the promising applicability of this technology to devices that generate large amounts of heat, such as electrical power converters, transformers and control systems. Likewise, it was statistically proved that the thermoelectric self cooling system leads to significant reductions in the temperature difference between the heat source and the environment, and, what is more, this reduction increases as the heat flow generated by the heat source increases, which makes evident the fact that thermoelectric self cooling systems work as temperature controllers. -- Highlights: → Novel concept of thermoelectric self cooling is presented and studied. → No extra electricity is needed. → Thermal resistance between the heat source and the environment reduces by 25-30%. → Increasing reduction in temperature difference between heat source and environment. → Great applicability to any device that generates heat and must be cooled.

  2. Evaluating the ergonomics of BCI devices for research and experimentation.

    Science.gov (United States)

    Ekandem, Joshua I; Davis, Timothy A; Alvarez, Ignacio; James, Melva T; Gilbert, Juan E

    2012-01-01

    The use of brain computer interface (BCI) devices in research and applications has exploded in recent years. Applications such as lie detectors that use functional magnetic resonance imaging (fMRI) to video games controlled using electroencephalography (EEG) are currently in use. These developments, coupled with the emergence of inexpensive commercial BCI headsets, such as the Emotiv EPOC ( http://emotiv.com/index.php ) and the Neurosky MindWave, have also highlighted the need of performing basic ergonomics research since such devices have usability issues, such as comfort during prolonged use, and reduced performance for individuals with common physical attributes, such as long or coarse hair. This paper examines the feasibility of using consumer BCIs in scientific research. In particular, we compare user comfort, experiment preparation time, signal reliability and ease of use in light of individual differences among subjects for two commercially available hardware devices, the Emotiv EPOC and the Neurosky MindWave. Based on these results, we suggest some basic considerations for selecting a commercial BCI for research and experimentation. STATEMENT OF RELEVANCE: Despite increased usage, few studies have examined the usability of commercial BCI hardware. This study assesses usability and experimentation factors of two commercial BCI models, for the purpose of creating basic guidelines for increased usability. Finding that more sensors can be less comfortable and accurate than devices with fewer sensors.

  3. Experimental results surprise quantum theory

    International Nuclear Information System (INIS)

    White, C.

    1986-01-01

    Interest in results from Darmstadt that positron-electron pairs are created in nuclei with high atomic numbers (in the Z range from 180-188) lies in the occurrence of a quantized positron kinetic energy peak at 300. The results lend substance to the contention of Erich Bagge that the traditionally accepted symmetries in positron-electron emission do not exist and, therefore, there is no need to posit the existence of the neutrino. The search is on for the decay of a previously unknown boson to account for the findings, which also points to the need for a major revision in quantum theory. 1 figure

  4. TMX-U experimental results

    International Nuclear Information System (INIS)

    Simonen, T.C.; Allen, S.L.; Casper, T.A.

    1983-01-01

    This paper describes results from the Tandem Mirror Experiment-Upgrade (TMX-U). Mirror-confined electrons with 30 to 70 keV mean energy densities of 0.5 to 2.0 x 10 12 cm -3 and average betas of 3 to 5% are produced using electron-cyclotron resonant heating (ECRH). These results are consistent with an electron Fokker-Planck code. Improved ion-cyclotron microstability is observed using neutral beam injection at 47 0 to the magnetic axis, rather than at 90 0 as in the previous experiment, TMX. Strong end plugging has been produced using a combination of ECRH gyrotrons with sloshing-ion beam injection. In these low-density central cell experiments (3 x 10 11 cm -3 ) the axial losses (tau/sub parallel/ = 20 to 80 ms) are smaller than the nonambipolar radial losses (tau/sub perpendicular/ = 4 to 8 ms). Plugging has been achieved with a central cell density double that of the end plugs. Although no direct measurements are yet available to determine if a thermal barrier potential dip is generated, these experiments support many theoretical features of the thermal barrier concept

  5. Experimental evaluation of cooling efficiency of the high performance cooling device

    Science.gov (United States)

    Nemec, Patrik; Malcho, Milan

    2016-06-01

    This work deal with experimental evaluation of cooling efficiency of cooling device capable transfer high heat fluxes from electric elements to the surrounding. The work contain description of cooling device, working principle of cooling device, construction of cooling device. Experimental part describe the measuring method of device cooling efficiency evaluation. The work results are presented in graphic visualization of temperature dependence of the contact area surface between cooling device evaporator and electronic components on the loaded heat of electronic components in range from 250 to 740 W and temperature dependence of the loop thermosiphon condenser surface on the loaded heat of electronic components in range from 250 to 740 W.

  6. Experimental evaluation of cooling efficiency of the high performance cooling device

    Energy Technology Data Exchange (ETDEWEB)

    Nemec, Patrik, E-mail: patrik.nemec@fstroj.uniza.sk; Malcho, Milan, E-mail: milan.malcho@fstroj.uniza.sk [University of Žilina, Faculty of Mechanical Engineering, Department of Power Engineering, Univerzitna 1, 010 26 Žilina (Slovakia)

    2016-06-30

    This work deal with experimental evaluation of cooling efficiency of cooling device capable transfer high heat fluxes from electric elements to the surrounding. The work contain description of cooling device, working principle of cooling device, construction of cooling device. Experimental part describe the measuring method of device cooling efficiency evaluation. The work results are presented in graphic visualization of temperature dependence of the contact area surface between cooling device evaporator and electronic components on the loaded heat of electronic components in range from 250 to 740 W and temperature dependence of the loop thermosiphon condenser surface on the loaded heat of electronic components in range from 250 to 740 W.

  7. Fuel performance evaluation for the CAFE experimental device

    International Nuclear Information System (INIS)

    Giovedi, Claudia; Hirota, Leandro T.

    2011-01-01

    Fuel rod cladding material is the second barrier to prevent the release of radioactive inventories in a PWR reactor. In this sense, an important safety aspect is to assess the fuel behavior under operational conditions. This can be made by means of fuel performance codes and confirmed by experimental measurements. In order to evaluate the fuel behavior of fuel rods in steady-state conditions, it was designed an experimental irradiation device, the Nuclear Fuel Irradiation Circuit (CAFE-Mod1). This device will allow controlling the surface rod temperature, to measure the power associated to the rod and the evolution of fission gas release for a typical PWR fuel pin. However, to support the experimental irradiation program, it is extremely important to simulate the experimental conditions using a fuel performance code. The aim of this paper is to evaluate some parameters and aspects related to the fuel rod behavior during the irradiation program. This evaluation was carried out by means of an adapted fuel performance code. Obtained results have shown that besides of the variation observed for parameters, such as, fuel temperature and fission gas release as a function of fuel enrichment level, the fuel rod integrity was preserved in all studied conditions. (author)

  8. Maximum neutron yeidls in experimental fusion devices

    International Nuclear Information System (INIS)

    Jassby, D.L.

    1979-02-01

    The optimal performances of 12 types of fusion devices are compared with regard to neutron production rate, neutrons per pulse, and fusion energy multiplication, Q/sub p/ (converted to the equivalent value in D-T operation). The record values in all categories are held by the beam-injected tokamak plasma, followed by other beam-target systems. The achieved values of Q/sub p/ for nearly all laboratory plasma fusion devices (magnetically or inertially confined) are found to roughly satisfy a common empirical scaling, Q/sub p/ approx. 10 -6 E/sub in//sup 3/2/, where E/sub in/ is the energy (in kilojoules) injected into the plasma during one or two energy confinement times, or the total energy delivered to the target for inertially confined systems. Fusion energy break-even (Q/sub p/ = 1) in any system apparently requires E/sub in/ approx. 10,000 kJ

  9. Recent experimental results and diagnostics on LHD

    International Nuclear Information System (INIS)

    Kawahata, Kazuo

    2001-01-01

    LHD is a superconducting heliotron type device with 1=2/m=10 continuous helical coils and three pairs of poloidal coils. The major and minor radii of the plasma are 3.5-3.9 m and 0.6 m, respectively. The plasma experiment was started at the end of March 1998 with the magnetic field of 1.5 T. Subsequently, the magnetic field has been gradually increased checking carefully the stability of the SC coils, and the maximum magnetic field used in the plasma experiment was 2.89 T at the magnetic axis of R ax =3.6 m. The heating power has been gradually increased, i.e., NBI up to 5.2 MW (with two beam lines), ICRF up to 2.7 MW (with two antenna system), and ECRH up to 1.0 MW (with six gyrotron tubes). The carbon tiles were installed as divertor plates to meet high power heatings, resulting in significant reduction in metal impurity concentration (Fe) and total radiation power. Upgrading of the key hardware system has led to (i) higher Te [Te(0)=4.4 keV at =5.3x10 18 m -3 and P abs =1.8 MW], (ii) higher confinement [τ E =0.3 s, Te(0)=1.1 keV at =6.5x10 19 m -3 and P abs =2.0 MW], (iii) higher stored energy W p dia =1.0 MJ, (iv) the highest β value in helical devices [2.4% at 1.3 T, >30% at 0.5 T]. In this workshop, we will report the recent experimental results on the LHD and plasma diagnostics related to mm and sub-mm wave diagnostics. (author)

  10. Experimental validation of models for Plasma Focus devices

    International Nuclear Information System (INIS)

    Rodriguez Palomino, Luis; Gonzalez, Jose; Clausse, Alejandro

    2003-01-01

    Plasma Focus(PF) Devices are thermonuclear pulsators that produce short pulsed radiation (X-ray, charged particles and neutrons). Since Filippov and Mather, investigations have been used to study plasma properties. Nowadays the interest about PF is focused in technology applications, related to the use of these devices as pulsed neutron sources. In the numerical calculus the Inter institutional PLADEMA (PLAsmas DEnsos MAgnetizados) network is developing three models. Each one is useful in different engineering stages of the Plasma Focus design. One of the main objectives in this work is a comparative study on the influence of the different parameters involved in each models. To validate these results, several experimental measurements under different geometry and initial conditions were performed. (author)

  11. A device for external γ-irradiation of experimental animals

    International Nuclear Information System (INIS)

    Ivanitskaya, N.F.; Talakin, Yu.N.; Lekakh, V.A.

    1992-01-01

    A device was developed for external gamma-irradiation of experimental animals including a radiation source, a device for fixation of the total animal or a segment of its body in the focus of irradiation, and a shilding screen. To widen the sphere of this device application by making possible a simultaneous radiation exposure of a group of animals under various radiation schedules, the device involves two discs with a common axis. The lower disc is provided with an electric drive and containers with animals are placed on it, and the upper disc is for the shielding screen. The device is supplied with an operation block

  12. Radioprotection problems resulting from the presence of experimental devices around an atomic reactor; Problemes de radioprotection poses par l'implantation de dispositifs experimentaux aupres d'une pile atomique

    Energy Technology Data Exchange (ETDEWEB)

    Fitoussi, L; Lebouleux, Ph; Bricard, Ph; Moreau, A [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1965-07-01

    The setting up of experimental devices around a reactor produces dangers of irradiation and radioactive contamination which can become very great in the case of an accident, especially if the in-pile portion contains fissile matter. This may result in irradiation of personnel, prohibition of access to the experimental zones until the sources of irradiation and contamination have been eliminated, and a prolonged stoppage of the reactor. The plans for an in-pile experiment should take into account radioprotection factors; the aim of these is to reduce to a minimum the radioactive risks normally encountered during the experiment and to eliminate any risks of bad accidents and their consequences. In this report are classified the various types of experiments requiring installations outside the pile itself; for each of these experiments the particular radioprotection factors are given. In order to make possible a study of the radioactive dangers likely to arise during a projected experiment, the authors summarize the physical and technical data required by radioprotection specialists and give the rules and general advice concerning radioprotection which should be useful during the planning of an in-pile experiment and the setting-up of the equipment. (authors) [French] L'implantation de dispositifs experimentaux aupres des reacteurs cree des risques d'irradiation et de contamination radioactive qui peuvent devenir importants en cas d'accident, surtout si la partie en pile comprend des matieres fissiles. Il peut en resulter des irradiations de personne, l'interdiction des aires experimentales jusqu'a elimination des sources d'irradiation et de contamination, un arret prolonge de la pile. L'etude d'un projet d'experience en pile doit donc tenir compte des considerations de radioprotection dont le souci est de reduire aux niveaux tolerables les risques radioactifs inherents au fonctionnement normal de l'experience et d'eliminer les risques d'accidents graves et leurs

  13. Device for rearranging control rods of experimental reactors

    International Nuclear Information System (INIS)

    Louda, J.

    1975-01-01

    The invention claims a means for the adjustment of control rods in experimental reactors with a continuously variable pitch of the fuel element spacer. The proposed device permits obtaining maximum variability in the physical modelling of nuclear power reactor cores in experimental reactors. (F.M.)

  14. Computations for a condenser. Experimental results

    International Nuclear Information System (INIS)

    Walden, Jean.

    1975-01-01

    Computations for condensers are presented with experimental results. The computations are concerned with the steam flux at the condenser input, and inside the tube bundle. Experimental results are given for the flux inside the condenser sleeve and the flow passing through the tube bundle [fr

  15. New experimental results on strangeness production

    International Nuclear Information System (INIS)

    Sapozhnikov, M.G.

    1998-01-01

    New experimental results on the production of φ and f 2 ' (1525) mesons in the annihilation of stopped antiprotons are discussed. The explanation of these facts in the framework of the polarized strangeness model is considered

  16. Experimental device for in-torus handling - EDITH intermediate report

    International Nuclear Information System (INIS)

    Suppan, A.; Krieg, R.; Krumm, H.G.; Kuehnapfel, U.; Leinemann, K.; Reim, J.; Woll, J.

    1993-10-01

    The Experimental Device for In-Torus Handling (EDITH) is based on articulated boom system (ABS), consisting of a support structure, the articulated boom transporter (ABT), the end-effector positioning unit (EEPU) and different end-effectors (EE's). It is the prototype of an in-vessel handling system for NET/ITER. In combination with a Full Scale Mock-up, EDITH is required to demonstrate that maintenance of plasma facing components can be carried out with the anticipated reliability and in time. A further aim of EDITH is to allow testing of the articulated boom components and subassemblies. The testbed EDITH and the Full Scale Mock-up are described. In addition, the performance and results of the commissioning and the qualification are summarized and an outlook is given for future tasks. (orig./HP) [de

  17. Simulations Results of an Ankle Rehabilitation Device

    Directory of Open Access Journals (Sweden)

    Ioan Doroftei

    2015-12-01

    Full Text Available The ankle structure is one of the most important structures of the human body. Due to its important role in human’s activities, this joint is the most injured part of the lower limb. For a complete recovery of the range of motion, recovery exercises are mandatory. The introduction of robotic physical recovery systems represents a modern alternative to traditional recovery. In this paper we present the development of a new ankle rehabilitation device, that aims to fully recover the range of motion required for daily activities.

  18. Electron density measurement in an evolving plasma. Experimental devices

    International Nuclear Information System (INIS)

    Consoli, Terenzio; Dagai, Michel

    1960-01-01

    The experimental devices described here allow the electron density measurements in the 10 16 e/m 3 to 10 20 e/m 3 interval. Reprint of a paper published in Comptes rendus des seances de l'Academie des Sciences, t. 250, p. 1223-1225, sitting of 15 February 1960 [fr

  19. Experimental results for a novel rotary active magnetic regenerator

    DEFF Research Database (Denmark)

    Engelbrecht, Kurt; Eriksen, Dan; Bahl, Christian

    2012-01-01

    Active magnetic regenerator (AMR) refrigerators represent an alternative to vapor compression technology and have great potential in realizing cooling devices with high efficiency, which are highly desirable for a broad range of applications. The technology relies on the magnetocaloric effect...... in a solid refrigerant rather than the temperature change that occurs when a gas is compressed/expanded. This paper presents the general considerations for the design and construction of a high frequency rotary AMR device. Experimental results are presented at various cooling powers for a range of operating...

  20. PDX experimental results in FY82

    International Nuclear Information System (INIS)

    Kaye, S.M.; Bell, M.; Bol, K.

    1983-08-01

    This report presents a detailed summary of the major experimental results of PDX in FY82 and represents the efforts of the entire PDX group. Topics covered include β-scaling and fishbone studies, fluctuations, disruptions, impurities and impurity transport, power handling, limiter conditioning, edge studies, plasma fueling, counter-injection, and diagnostic development. A less detailed version will appear as the FY82 PDX contribution to the PPPL Annual Report

  1. Predictions of High Energy Experimental Results

    Directory of Open Access Journals (Sweden)

    Comay E.

    2010-10-01

    Full Text Available Eight predictions of high energy experimental results are presented. The predictions contain the $Sigma ^+$ charge radius and results of two kinds of experiments using energetic pionic beams. In addition, predictions of the failure to find the following objects are presented: glueballs, pentaquarks, Strange Quark Matter, magnetic monopoles searched by their direct interaction with charges and the Higgs boson. The first seven predictions rely on the Regular Charge-Monopole Theory and the last one relies on mathematical inconsistencies of the Higgs Lagrangian density.

  2. Transient experimental demonstration of an elliptical thermal camouflage device.

    Science.gov (United States)

    He, Xiao; Yang, Tianzhi; Zhang, Xingwei; Wu, Linzhi; He, Xiao Qiao

    2017-11-30

    The camouflage phenomenon (invisibility or illusion) of thermodynamics has attracted great attentions and many experimental demonstrations have been achieved by virtue of simplified approaches or the scattering cancellation. However, all of the experiments conducted are limited in the invisibility of spheres or two-dimensional (2D) cylinders. An ellipsoid camouflage device with a homogenous and isotropic shell is firstly reported based on the idea of the neutral inclusion and a 2D elliptical thermal camouflage device is realized by a thin-layer cloak of homogeneous isotropic material firstly. The robustness of this scheme is validated in both 2D and 3D configurations. The current work may provide a new avenue to the control of the thermal signatures and we believe this work will broaden the current research and pave a new path to the control of the path of the heat transfer.

  3. F(α) curves: Experimental results

    International Nuclear Information System (INIS)

    Glazier, J.A.; Gunaratne, G.; Libchaber, A.

    1988-01-01

    We study the transition to chaos at the golden and silver means for forced Rayleigh-Benard (RB) convection in mercury. We present f(α) curves below, at, and above the transition, and provide comparisons to the curves calculated for the one-dimensional circle map. We find good agreement at both the golden and silver means. This confirms our earlier observation that for low amplitude forcing, forced RB convection is well described by the one-dimensional circle map and indicates that the f(α) curve is a good measure of the approach to criticality. For selected subcritical experimental data sets we calculate the degree of subcriticality. We also present both experimental and calculated results for f(α) in the presence of a third frequency. Again we obtain agreement: The presence of random noise or a third frequency narrows the right-hand (negative q) side of the f(α) curve. Subcriticality results in symmetrically narrowed curves. We can also distinguish these cases by examining the power spectra and Poincare sections of the time series

  4. Experimental results from a stepped frequency GPR

    Directory of Open Access Journals (Sweden)

    G. M. Signore

    2003-06-01

    Full Text Available In the framework of a nationally funded project, a Ground Penetrating Radar (GPR has been developed by the Italian Consortium for Research on Advanced Remote Sensing Systems (CO.RI.S.T.A.. The system was described in a previous paper (Alberti et al., 2002. As new aspects, the system is a stepped frequency GPR that can work both in gated and ungated mode, and the antennas can be moved automatically in a controlled fashion. As aspects of geophysical interest, the system is exploitable in situations wherein a high resolution and a shallow penetration in the soil (a few meters are required. Possibly, this is an example of probing a landscape. This paper completes the results of Alberti et al. (2002, wherein laboratory tests where described, by providing the main results obtained during an outdoor experimental campaign, performed fi rst in a controlled site and then in an archaeological site.

  5. Experimental device for measuring the dynamic properties of diaphragm motors

    Science.gov (United States)

    Fojtášek, Kamil; Dvořák, Lukáš; Mejzlík, Jan

    The subject of this paper is to design and description of the experimental device for the determination dynamic properties of diaphragm pneumatic motors. These motors are structurally quite different from conventional pneumatic linear cylinders. The working fluid is typically compressed air, the piston of motor is replaced by an elastic part and during the working cycle there is a contact of two elastic environments. In the manufacturers catalogs of these motors are not given any working characteristics. Description of the dynamic behavior of diaphragm motor will be used for verification of mathematical models.

  6. Overview of the initial NSTX experimental results

    International Nuclear Information System (INIS)

    Ono, M.; Bell, M.G.; Bell, R.E.

    2001-01-01

    The main aim of the National Spherical Torus Experiment (NSTX) is to establish the fusion physics principles of the spherical torus (ST) concept. The NSTX device began plasma operations in February 1999 and the plasma current I p was successfully brought up to the design value of 1 MA on 14 December 1999. The planned plasma shaping parameters, elongation κ=1:6-2.2 and triangularity δ=0:2-0.4, were achieved in inner wall limited, and single null and double null diverted configurations. The coaxial helicity injection (CHI) and high harmonic fast wave (HHFW) experiments were also initiated. CHI current of 27 kA produced up to 260 kA toroidal current without using an ohmic solenoid. With the injection of 2.3 MW of HHFW power, using 12 antennas connected to six transmitters, electrons were heated from a central temperature of 400 eV to 900 eV at a central density of 3.5x10 13 cm 3 , increasing the plasma energy to 59 kJ and the toroidal β, β T , to 10%. The NBI system commenced operation in September 2000. The initial results with two ion sources (P NBI =2:8 MW) show good heating, producing a total plasma stored energy of 90 kJ corresponding to β T ∼18% at a plasma current of 1.1 MA. (author)

  7. Experimental results from the TUMAN 3 tokamak

    International Nuclear Information System (INIS)

    Golant, V.E.; Andrejko, M.V.; Askinazi, L.G.; Korneev, V.A.; Krikunov, S.V.; Lipin, B.M.; Lebedev, S.V.; Levin, L.S.; Podushnikova, K.A.; Razdobarin, G.T.; Rozhansky, V.A.; Rozhdestvensky, V.V.; Tendler, M.; Tukachinsky, A.S.; Jaroshevich, S.P.

    1995-01-01

    The open-quote open-quote TUMAN-3 close-quote close-quote Tokamak programme concentrates on issues of improved confinement. In 1989 the transition from an ordinary Ohmic regime into an improved confinement mode was achieved. The signatures of the H-mode in auxiliary heated tokamaks have been observed in this regime. The crucial role of the boundary radial electric field was found in the experiments with internal bias probe. Other techniques were demonstrated to disturb the boundary plasma which led to H-mode triggering: short increase of working gas puffing, minor radius magnetic compression and pellet injection. The role scaling of the energy confinement time in the Ohmic H-mode was obtained, which differs dramatically from the scaling for the ordinary Ohmic regime. There were found a strong dependence of τ E on plasma current and a weak dependence on density. The maximum value of τ E was 10 times longer than in the ordinary Ohmic region. The τ E scaling for the Ohmic H-mode is consistent with the scaling proposed for devices with powerful auxiliary heating. The results shows that H-mode physics is universal in tokamaks with different geometries and heating methods. (AIP) copyright 1995 American Institute of Physics

  8. Overview of the initial NSTX experimental results

    International Nuclear Information System (INIS)

    Ono, M.; Bell, M.; Bell, R.

    2001-01-01

    The main aim of the National Spherical Torus Experiment (NSTX) is to establish the fusion physics principles of the spherical torus (ST) concept. The NSTX device began plasma operations in February 1999 and the plasma current I p was successfully brought up to the design value of 1 million amperes on December 14, 1999. The planned plasma shaping parameters, κ=1.6-2.2 and δ=0.2-0.4, were achieved in inner limited, single null and double null configurations. The CHI (Coaxial Helicity Injection) and HHFW (High Harmonic Fast Wave) experiments were also initiated. A CHI injected current of 27 kA produced up to 260 kA of toroidal current without using an ohmic solenoid. With an injection of 2.3 MW of HHFW power, using twelve antennas connected to six transmitters, electrons were heated from a central temperature of 400 eV to 900 eV at a central density of 3.5x10 13 cm -3 increasing the plasma energy to 59 kJ and the toroidal beta, β T to 10 %. Finally, the NBI system commenced operation in Sept. 2000. The initial results with two ion sources (P NBI =2.8MW) shows good heating, producing a total plasma stored energy of 90 kJ corresponding to β T ∼18% at a plasma current of 1.1 MA. (author)

  9. Overview of the Initial NSTX Experimental Results

    International Nuclear Information System (INIS)

    Ono, M.; Bell, M.; Bell, R. E.; Bigelow, T.; Bitter, M.

    2000-01-01

    The main aim of the National Spherical Torus Experiment (NSTX) is to establish the fusion physics principles of the spherical torus (ST) concept. The NSTX device began plasma operations in February 1999 and the plasma current Ip was successfully brought up to the design value of 1 million amperes on December 14, 1999. The planned plasma shaping parameters, k = 1.6 ± 2.2 and d = 0.2 ± 0.4, were achieved in inner limited, single null and double null configurations. The CHI (Coaxial Helicity Injection) and HHFW (High Harmonic Fast Wave) experiments were also initiated. A CHI injected current of 27 kA produced up to 260 kA of toroidal current without using an ohmic solenoid. With an injection of 2.3 MW of HHFW power, using twelve antennas connected to six transmitters, electrons were heated from a central temperature of 400 eV to 900 eV at a central density of 3.5 x 1013 cm-3 increasing the plasma energy to 59 kJ and the toroidal beta, bT to 10 %. Finally, the NBI system commenced operation in Sept. 2000. The initial results with two ion sources (PNBI = 2.8 MW) shows good heating, producing a total plasma stored energy of 90 kJ corresponding to bT = 18 % at a plasma current of 1.1 MA

  10. Experimental and numerical results of a high frequency rotating active magnetic refrigerator

    DEFF Research Database (Denmark)

    Lozano, Jaime; Engelbrecht, Kurt; Bahl, Christian

    2012-01-01

    Experimental results for a recently developed prototype magnetic refrigeration device at The Technical University of Denmark (DTU) were obtained and compared with numerical simulation results. A continuously rotating active magnetic regenerator (AMR) using 2.8 kg packed sphere regenerators...

  11. Experimental and numerical results of a high frequency rotating active magnetic refrigerator

    DEFF Research Database (Denmark)

    Lozano, Jaime; Engelbrecht, Kurt; Bahl, Christian R.H.

    2014-01-01

    Experimental results for a recently developed prototype magnetic refrigeration device at the Technical University of Denmark (DTU) were obtained and compared with numerical simulation results. A continuously rotating active magnetic regenerator (AMR) using 2.8 kg packed sphere regenerators...

  12. In-pile experimental device for Sirene thermionic converters

    International Nuclear Information System (INIS)

    Bliaux, J.; Durand, J.; Lazare-Chopard, G.

    1969-01-01

    The irradiation device described here, was built for in pile life tests of 100 We SIRENE converters. The nuclear converter is located in a sealed vacuum chamber, which is plugged at the lower end of a coaxial tubing acting as electrical leads. The output power is available on a variable resistive load on the bank of the reactor pool. Thermal, electrical and neutronic parameters of the converter are recorded. Since 1967, two permanent devices allowed five experiments in the swimming pool TRITON (CEN-FAR) and the results, obtained till now, are presented. (authors) [fr

  13. Electrical insulation and conduction coating for fusion experimental devices

    Energy Technology Data Exchange (ETDEWEB)

    Onozuka, Masanori; Tsujimura, Seiji; Toyoda, Masahiko; Inoue, Masahiko [Mitsubishi Heavy Industries, Ltd., Yokohama (Japan); Abe, Tetsuya; Murakami, Yoshio [Japan Atomic Energy Research Inst., Naka (Japan)

    1996-01-01

    The development of electrical insulation and conduction coating methods that can be applied to large components of fusion experimental devices has been investigated. A thermal spraying method is used to coat the insulation or conduction materials on the structural components because of its applicability for large surfaces. The insulation material chosen was Al{sub 2}O{sub 3}, while Cr{sub 3}C{sub 2}-NiCr and WC-NiCr were chosen as conduction materials. These materials were coated on stainless steel substrates to examine the basic characteristics of the coated layers, such as their adhesive strength to the substrate, thermal shock resistance, electrical resistance, dielectric breakdown voltage, and thermal conductivity. It was found that they have sufficient electrical insulation and conduction properties, respectively. In addition, the sliding tests of the coated layers showed adequate frictional properties. The spraying method was tested on a 100- x 1000-mm surface and found to be applicable for large surfaces of experimental fusion devices. 9 refs., 6 figs., 15 tabs.

  14. Electrical insulation and conduction coating for fusion experimental devices

    International Nuclear Information System (INIS)

    Onozuka, Masanori; Tsujimura, Seiji; Toyoda, Masahiko; Inoue, Masahiko; Abe, Tetsuya; Murakami, Yoshio

    1996-01-01

    The development of electrical insulation and conduction coating methods that can be applied to large components of fusion experimental devices has been investigated. A thermal spraying method is used to coat the insulation or conduction materials on the structural components because of its applicability for large surfaces. The insulation material chosen was Al 2 O 3 , while Cr 3 C 2 -NiCr and WC-NiCr were chosen as conduction materials. These materials were coated on stainless steel substrates to examine the basic characteristics of the coated layers, such as their adhesive strength to the substrate, thermal shock resistance, electrical resistance, dielectric breakdown voltage, and thermal conductivity. It was found that they have sufficient electrical insulation and conduction properties, respectively. In addition, the sliding tests of the coated layers showed adequate frictional properties. The spraying method was tested on a 100- x 1000-mm surface and found to be applicable for large surfaces of experimental fusion devices. 9 refs., 6 figs., 15 tabs

  15. Utilization of Remote Experimentation in Mobile Devices for Education

    Directory of Open Access Journals (Sweden)

    Willian Rochadel

    2012-07-01

    Full Text Available In this paper the authors intend to demonstrate the utilization of remote experimentation (RE using mobile computational devices in the Science areas of the elementary school, with the purpose to develop practices that will help in the assimilation process of the subjects taught in classroom seeking to interlink them with the daily students’ activities. Allying mobility with RE we intend to minimize the space-temporal barrier giving more availability and speed in the information access. The implemented architecture utilizes technologies and freely distributed softwares with open code resources besides remote experiments developed in the Laboratory of Remote Experimentation (RExLab of Federal University of Santa Catarina (UFSC, in Brazil, through the physical computation platform of the “open hardware” of construction of our own. The utilization of open code computational tools and the integration of hardware to the 3D virtual worlds, accessible through mobile devices, give to the project an innovative face with a high potential for reproducibility and reusability.

  16. Design of Passive Acoustic Wave Shaping Devices and Their Experimental Validation

    DEFF Research Database (Denmark)

    Christiansen, Rasmus Ellebæk; Sigmund, Ole; Fernandez Grande, Efren

    We discuss a topology optimization based approach for designing passive acoustic wave shaping devices and demonstrate its application to; directional sound emission [1], sound focusing and wave splitting. Optimized devices, numerical and experimental results are presented and benchmarked against...... other designs proposed in the literature. We focus on design problems where the size of the device is on the order of the wavelength, a problematic region for traditional design methods, such as ray tracing.The acoustic optimization problem is formulated in the frequency domain and modeled...

  17. Recent results on medium-size plasma-focus device

    International Nuclear Information System (INIS)

    Miklaszewski, R.; Kasperczuk, A.; Paduch, M.; Tomaszewaski, K.; Wereszczynski, Z.

    1992-01-01

    A brief history of investigation carried out on the PF-150 plasma-focus device is presented. Essential results concerning the dynamics of plasma sheath are summarized. The present state of investigation and main areas of interest are shown. (author)

  18. Experimental model of the device for detection of nuclear cycle materials by photoneutron technology

    International Nuclear Information System (INIS)

    Bakalyarov, A.M.; Karetnikov, M.D.; Kozlov, K.N.; Lebedev, V.I.; Meleshko, E.A.; Obinyakov, B.A.; Ostashev, I.E.; Tupikin, N.A.; Yakovlev, G.V.

    2007-01-01

    The inherent complexity of sea container control makes them potentially dangerous for smuggling nuclear materials. The experts believe that only active technologies based on recording the products of induced radiation from sensitive materials might solve the problem. The paper reports on the experimental model of the device on the basis of the electron LINAC U-28 for detection of nuclear materials by photonuclear technology. The preliminary numerical optimization of output units (converter, filter, collimator) for shaping the bremsstrahlung was carried out. The setup of experimental device and initial results of recording the prompt and delayed fission products are discussed

  19. Analytical and Experimental Study for Validation of the Device to Confine BN Reactor Melted Fuel

    International Nuclear Information System (INIS)

    Rogozhkin, S.; Osipov, S.; Sobolev, V.; Shepelev, S.; Kozhaev, A.; Mavrin, M.; Ryabov, A.

    2013-01-01

    To validate the design and confirm the design characteristics of the special retaining device (core catcher) used for protection of BN reactor vessel in the case of a severe beyond-design basis accident with core melting, computational and experimental studies were carried out. The Tray test facility that uses water as coolant was developed and fabricated by OKBM; experimental studies were performed. To verify the methodical approach used for the computational study, experimental results obtained in the Tray test facility were compared with numerical simulation results obtained by the STAR-CCM+ CFD code

  20. Railgun pellet injection system for fusion experimental devices

    Energy Technology Data Exchange (ETDEWEB)

    Onozuka, M. [Mitsubishi Heavy Industries Ltd., Yokohama (Japan). Adv. Tech. Dev. Dept.; Oda, Y. [Mitsubishi Heavy Industries Ltd., Yokohama (Japan). Adv. Tech. Dev. Dept.; Azuma, K. [Mitsubishi Heavy Industries Ltd., Yokohama (Japan). Adv. Tech. Dev. Dept.; Satake, K. [Mitsubishi Heavy Industries Ltd., Yokohama (Japan). Adv. Tech. Dev. Dept.; Kasai, S. [Japan Atomic Energy Research Institute, Tokai-mura, Naka-gun 319-11 (Japan); Hasegawa, K. [Japan Atomic Energy Research Institute, Tokai-mura, Naka-gun 319-11 (Japan)

    1995-11-01

    A railgun pellet injection system has been developed for fusion experimental devices. Using a low electric energy railgun system, hydrogen pellet acceleration tests have been conducted to investigate the application of the electromagnetic railgun system for high speed pellet injection into fusion plasmas. In the system, the pellet is pre-accelerated before railgun acceleration. A laser beam is used to induce plasma armature. The ignited plasma armature is accelerated by an electromagnetic force that accelerates the pellet. Under the same operational conditions, the energy conversion coefficient for the dummy pellets was around 0.4%, while that for the hydrogen pellets was around 0.12%. The highest hydrogen pellet velocity was 1.4 km s{sup -1} using a 1 m long railgun. Based on the findings, it is estimated that the hydrogen pellet has the potential to be accelerated to 5 km s{sup -1} using a 3 m long railgun. (orig.).

  1. Railgun pellet injection system for fusion experimental devices

    International Nuclear Information System (INIS)

    Onozuka, M.; Hasegawa, K.

    1995-01-01

    A railgun pellet injection system has been developed for fusion experimental devices. Using a low electric energy railgun system, hydrogen pellet acceleration tests have been conducted to investigate the application of the electromagnetic railgun system for high speed pellet injection into fusion plasmas. In the system, the pellet is pre-accelerated before railgun acceleration. A laser beam is used to induce plasma armature. The ignited plasma armature is accelerated by an electromagnetic force that accelerates the pellet. Under the same operational conditions, the energy conversion coefficient for the dummy pellets was around 0.4%, while that for the hydrogen pellets was around 0.12%. The highest hydrogen pellet velocity was 1.4 km s -1 using a 1 m long railgun. Based on the findings, it is estimated that the hydrogen pellet has the potential to be accelerated to 5 km s -1 using a 3 m long railgun. (orig.)

  2. Experimental Flow Characterization of a Flow Diverting Device

    Science.gov (United States)

    Sparrow, Eph; Chow, Ricky; Campbell, Gary; Divani, Afshin; Sheng, Jian

    2012-11-01

    Flow diverters, such as the Pipeline Embolization Device, are a new class of endovascular devices for the treatment of intracranial aneurysms. While clinical studies have demonstrated safety and efficacy, their impact on intra-aneurysmal flow is not confirmed experimentally. As such, optimization of the flow diversion behavior is not currently possible. A quasi-3D PIV technique was developed and applied in various glass models at Re = 275 and 550 to determine the changes to flow characteristics due to the deployment of a flow diverter across the aneurysm neck. Outcomes such as mean velocity, wall shear stress, and others metrics will be presented. Glass models with varying radii of curvature and aneurysm locations will be examined. Experiments were performed in a fully index-matched flow facility using ~10 μm diameter polystyrene particles doped with Rhodium 6G dye. The particles were illuminated with a 532nm laser sheet and observed with a CCD camera and a 592nm +/-43 nm bandpass filter. A quasi 3D flow field was reconstructed from multiple orthogonal planes (spaced 0.4mm apart) encompassing the entire glass model. Wall stresses were evaluated from the near-wall flow viscous stresses.

  3. EXPERIMENTAL VERIFICATION OF COMPUTER MODEL OF COOLING SYSTEM FOR POWERFUL SEMI- CONDUCTOR DEVICE

    Directory of Open Access Journals (Sweden)

    I. A. Khorunzhii

    2007-01-01

    Full Text Available A cooling system for powerful semi-conductor device (power -1 kW consisting of a pin-type radiator and a body is considered in the paper. Cooling is carried out by forced convection of a coolant. Calculated values of temperatures on the radiator surface and experimentally measured values of temperatures in the same surface points have been compared in the paper. It has been shown that the difference between calculated and experimentally measured temperatures does not exceed 0,1-0,2 °C and it is comparable with experimental error value. The given results confirm correctness of a computer model.

  4. Updating experimental results on light meson spectroscopy

    International Nuclear Information System (INIS)

    Diekmann, B.

    1991-06-01

    A recollection and summary is given on the understanding of light qanti q (q = u,d,s) mesons under the regime of the qanti q potential turning from a coulombic behaviour to a 'confining' one. In the second part the experimental knowledge obtained in the last years is updated: e + e - experiments, fixed target experiments with hadrons (kaons) and photons and panti p annihilations at LEAR discovered unknown objects and added new constraints on known but not fully understood states. (orig.)

  5. Research on condensed matter and atomic physics, using major experimental facilities and devices: Physics, chemistry, biology. Reports on results. Vol. 1. 1. Atomic and molecular physics. 2. Physics and chemistry of surfaces and interfaces

    International Nuclear Information System (INIS)

    1993-01-01

    This report in three volumes substantiates the contents of the programme survey published in September 1989. The progress reports cover the following research areas: Vol. I, (1). Atomic and molecular physics - free atoms, molecules, macromolecules, clusters, matrix-isolated atoms and molecules. (2) Physics and chemistry of surfaces and interfaces - epitaxy, surface structure, adsorption, electrical, magnetic, and optical properties, thin films, synthetic layer structure. Vol. II, (3). Solid-state physics, and materials science -structural research, lattice dynamics, magnetic structure and dynamics, electronic states; load; spin and pulse density fluctuations; diffusion and internal motion, defects, unordered systems and liquids. Vol. III, (4). Chemistry - bonding and structure, kinetics and reaction mechanisms, polymer research, analysis and synthesis. (5). Biology, - structure and dynamics of biological macromolecules, membrane and cell biology. (6) Development of methods and instruments - neutron sources, synchrotron sources, special accelerators, research with interlinked systems and devices. (orig.) [de

  6. Research on condensed matter and atomic physics using major experimental facilities and devices: Physics, chemistry, biology. Reports on results. Vol. 3. 4. Chemistry. 5. Biology. 6. Development of methods and instruments

    International Nuclear Information System (INIS)

    1993-01-01

    This report in three volumes substantiates the contents of the programme survey published in September 1989. The progress reports cover the following research areas: Vol. I, (1). Atomic and molecular physics - free atoms, molecules, macromolecules, clusters, matrix-isolated atoms and molecules. (2) Physics and chemistry of surfaces and interfaces - epitaxy, surface structure, adsorption, electrical, magnetic, and optical properties, thin films, synthetic layer structure. Vol. II, (3). Solid-state physics, and materials science -structural research, lattice dynamics, magnetic structure and dynamics, electronic states; load; spin and pulse density fluctuations; diffusion and internal motion, defects, unordered systems and liquids. Vol. III, (4). Chemistry - bonding and structure, kinetics and reaction mechanisms, polymer research, analysis and synthesis. (5). Biology, - structure and dynamics of biological macromolecules, membrane and cell biology. (6) Development of methods and instruments - neutron sources, synchrotron sources, special accelerators, research with interlinked systems and devices. (orig.) [de

  7. Overview of results from the Large Helical Device

    International Nuclear Information System (INIS)

    Yamada, H.

    2010-11-01

    The physical understanding of net-current free helical plasmas has progressed in the Large Helical Device (LHD) since the last Fusion Energy Conference in Geneva, 2008. The experimental results from LHD have promoted detailed physical documentation of features specific to net-current-free 3-D helical plasmas as well as complementary to the tokamak approach. The primary heating source is NBI with a heating power of 23 MW, and ECH with 3.7 MW plays an important role in local heating and power modulation in transport studies. The maximum central density has reached 1.2 x 10 21 m -3 due to the formation of an Internal Diffusion Barrier (IDB) at the magnetic field of 2.5 T. The IDB has been maintained for 3 s by refueling with repetitive pellet injection. The plasma with a central ion temperature reaching 5.6 keV exhibits the formation of an Internal Transport Barrier (ITB). The ion thermal diffusivity decreases to the level predicted by neoclassical transport. This ITB is accompanied by spontaneous toroidal rotation and an Impurity Hole which generates an impurity-free core. Impurity Hole is due to a large outward convection of impurities in spite of the negative radial electric field. The magnitude of the Impurity Hole is enhanced in the magnetic configuration with larger helical ripple and for higher Z impurities. Another mechanism to suppress impurity contamination has been identified at the plasma edge with a stochastic magnetic field. A helical system shares common physics issues with tokamaks such as 3-D equilibria, transport in a stochastic magnetic field, plasma response to a Resonant Magnetic Perturbation (RMP), divertor physics, and the role of radial electric field and meso-scale structure. (author)

  8. Experimental Device for Learning of Logical Circuit Design using Integrated Circuits

    OpenAIRE

    石橋, 孝昭

    2012-01-01

    This paper presents an experimental device for learning of logical circuit design using integrated circuits and breadboards. The experimental device can be made at a low cost and can be used for many subjects such as logical circuits, computer engineering, basic electricity, electrical circuits and electronic circuits. The proposed device is effective to learn the logical circuits than the usual lecture.

  9. Experimental facility of innovative types as the laboratory analog of research reactor experimental device

    International Nuclear Information System (INIS)

    Androsenko, A.A.; Androsenko, P.A.; Zabud'ko, A.N.; Kremenetskij, A.K.; Nikolaev, A.N.; Trykov, L.A.

    1991-01-01

    The paper analyses capability of creating laboratory analogs of complex experimental facilities at research reactors utilizing power radionuclide neutron sources fabricated in industrial conditions. Some experimental and calculational investigations of neutron-physical characteristics are presented, which have been attained at the RIZ research reactor laboratory analog. Experimental results are supplemented by calculational investigations, fulfilled by means of the BRAND three-dimensional computational complex and the ROZ-6 one-dimensional program. 4 refs.; 3 figs

  10. MYRRHA/XT-ADS primary system design and experimental devices

    International Nuclear Information System (INIS)

    Maes, D.

    2009-01-01

    The EUROTRANS project is an integrated project in the Sixth European Framework Program in the context of Partitioning and Transmutation. The objective of this project is to work towards an ETD (European Transmutation Demonstration) in a step-wise manner. The first step is to carry out an advanced design of a small-scale XT-ADS (eXperimental Transmutation in an Accelerator Driven System) for realisation in a short-term (about 10 years) as well as to accomplish a generic conceptual design of EFIT (European Facility for Industrial Transmutation) for realisation in the long-term. The MYRRHA-2005 design served as a starting basis for the XT-ADS. Many options have been revisited and the framework is now set up. While the MYRRHA-2005 design was still a conceptual design, the intention is to get at the end of the EUROTRANS project (March 2009) an advanced design of the XT-ADS, albeit a first advanced design. While the design work performed during the first years of the project (2005-2006) was mainly devoted to optimise and enhance the primary and secondary system configuration according to the suggestions and contributions of our industrial partners (Ansaldo Nucleare, Areva, Suez-Tractebel) within the DM1 (Domain 1 D ESIGN ) , the last year work objectives mainly consisted of (1) the release of the Remote Handling Design Catalogue for XT-ADS and (2) the formulation of the specification of the experimental devices according to the XT-ADS objectives and adapted to the actual XT-ADS core and core support structure design; (3) the detailed calculations of the main XT-ADS primary and secondary system components

  11. Experimental results of the betatron sum resonance

    International Nuclear Information System (INIS)

    Wang, Y.; Ball, M.; Brabson, B.

    1993-06-01

    The experimental observations of motion near the betatron sum resonance, ν x + 2ν z = 13, are presented. A fast quadrupole (Panofsky-style ferrite picture-frame magnet with a pulsed power supplier) producing a betatron tune shift of the order of 0.03 at rise time of 1 μs was used. This quadrupole was used to produce betatron tunes which jumped past and then crossed back through a betatron sum resonance line. The beam response as function of initial betatron amplitudes were recorded turn by turn. The correlated growth of the action variables, J x and J z , was observed. The phase space plots in the resonance frame reveal the features of particle motion near the nonlinear sum resonance region

  12. New experimental results on beam-plasma interaction in solenoids

    International Nuclear Information System (INIS)

    Arzhannikov, A.V.; Burdakov, A.V.; Kapitonov, V.A.

    1988-01-01

    New results are presented on studying the beam-plasma interaction and plasma heating dynamics at the INAR device. The specific features of the generation of ''hot'' (E greater than or ∼ 1 keV) plasma electrons containing the main part of the plasma energy are studied. In the case of a beam with a small initial angular spread, the ''hot'' electrons are shown to be mainly generated near the point where the beam is injected into the plasma. Also reported are the results of the experiments in which the magnetic field in the beam-plasma interaction region was increased up to 70 kOe. In this case, at the plasma length of 75 cm, the total beam energy losses exceed 40%. The growth of the plasma energy content at higher magnetic field is observed. The first stage of the GOL-3 experiment is described which is aimed at the study of the plasma heating is solonoid by a 100 kJ microsecond electron beam. This new experimental device is now ready for operation (author)

  13. Specifics of phytomass combustion in small experimental device

    Science.gov (United States)

    Lenhard, Richard; Mičieta, Jozef; Jandačka, Jozef; Gavlas, Stanislav

    2015-05-01

    A wood pellet combustion carries out with high efficiency and comfort in modern pellet boilers. These facts help to increase the amount of installed pellet boilers in households. The combustion process quality depends besides the combustion conditions also on the fuel quality. The wood pellets, which don`t contain the bark and branches represent the highest quality. Because of growing pellet demand, an herbal biomass (phytomass), which is usually an agricultural by-product becomes economically attractive for pellet production. Although the phytomass has the net calorific value relatively slightly lower than the wood biomass, it is often significantly worse in view of the combustion process and an emission production. The combustion of phytomass pellets causes various difficulties in small heat sources, mainly due to a sintering of fuel residues. We want to avoid the ash sintering by a lowering of temperature in the combustion chamber below the ash sintering temperature of phytomass via the modification of a burner design. For research of the phytomass combustion process in the small boilers is constructed the experimental combustion device. There will investigate the impact of cooling intensity of the combustion chamber on the combustion process and emissions. Arising specific requirements from the measurement will be the basis for the design of the pellet burner and for the setting of operating parameters to the trouble-free phytomass combustion was guaranteed.

  14. Specifics of phytomass combustion in small experimental device

    Directory of Open Access Journals (Sweden)

    Lenhard Richard

    2015-01-01

    Full Text Available A wood pellet combustion carries out with high efficiency and comfort in modern pellet boilers. These facts help to increase the amount of installed pellet boilers in households. The combustion process quality depends besides the combustion conditions also on the fuel quality. The wood pellets, which don`t contain the bark and branches represent the highest quality. Because of growing pellet demand, an herbal biomass (phytomass, which is usually an agricultural by-product becomes economically attractive for pellet production. Although the phytomass has the net calorific value relatively slightly lower than the wood biomass, it is often significantly worse in view of the combustion process and an emission production. The combustion of phytomass pellets causes various difficulties in small heat sources, mainly due to a sintering of fuel residues. We want to avoid the ash sintering by a lowering of temperature in the combustion chamber below the ash sintering temperature of phytomass via the modification of a burner design. For research of the phytomass combustion process in the small boilers is constructed the experimental combustion device. There will investigate the impact of cooling intensity of the combustion chamber on the combustion process and emissions. Arising specific requirements from the measurement will be the basis for the design of the pellet burner and for the setting of operating parameters to the trouble-free phytomass combustion was guaranteed.

  15. Terminal illness and access to Phase 1 experimental agents, surgeries and devices: reviewing the ethical arguments.

    Science.gov (United States)

    Schüklenk, Udo; Lowry, Christopher

    2009-01-01

    The advent of AIDS brought about a group of patients unwilling to accept crucial aspects of the methodological standards for clinical research investigating Phase 1 drugs, surgeries or devices. Their arguments against placebo controls in trials, which depended--at the time--on the terminal status of patient volunteers led to a renewed discussion of the ethics of denying patients with catastrophic illnesses access to last-chance experimental drugs, surgeries or devices. Existing ethics and health policy literature on the topic of access to experimental drugs. The positions of those arguing for or against free access to experimental drugs for terminally ill patients are irreconcilable. At stake are questions about the kinds of personal sacrifices society can reasonably expect patients in clinical trials to make to ensure statistically predictive results. These would benefit by necessity a much larger number of current and future patients--the conflict is about individual versus public interests. It is also about the question of whether or not the state can legitimately prevent patients with terminal illnesses from unfettered access to experimental drugs, surgeries or devices in order to motivate them to participate in clinical trials. We review the ethical arguments for and against the provision of access to Phase 1 agents for terminally ill patients. Finding a compromise between providing free or no access to Phase 1 drugs for terminally ill patients. We ought to investigate means to increase access to experimental drugs for terminally ill patients without sacrificing necessary clinical trials' sounds scientific methods.

  16. Experimental study of elementary collection efficiency of aerosols by spray: Design of the experimental device

    Energy Technology Data Exchange (ETDEWEB)

    Ducret, D.; Vendel, J.; Garrec. S.L.

    1995-02-01

    The safety of a nuclear power plant containment building, in which pressure and temperature could increase because of a overheating reactor accident, can be achieved by spraying water drops. The spray reduces the pressure and the temperature levels by condensation of steam on cold water drops. The more stringent thermodynamic conditions are a pressure of 5.10{sup 5} Pa (due to steam emission) and a temperature of 413 K. Moreover its energy dissipation function, the spray leads to the washout of fission product particles emitted in the reactor building atmosphere. The present study includes a large program devoted to the evaluation of realistic washout rates. The aim of this work is to develop experiments in order to determine the collection efficiency of aerosols by a single drop. To do this, the experimental device has to be designed with fundamental criteria:-Thermodynamic conditions have to be representative of post-accident atmosphere. Thermodynamic equilibrium has to be attained between the water drops and the gaseous phase. Thermophoretic, diffusiophoretic and mechanical effects have to be studied independently. Operating conditions have to be homogenous and constant during each experiment. This paper presents the design of the experimental device. In practice, the consequences on the design of each of the criteria given previously and the necessity of being representative of the real conditions will be described.

  17. Experimental studies on the flow characteristics in an inclined bend-free OWC device

    Directory of Open Access Journals (Sweden)

    Krishnil Ravinesh Ram

    2016-01-01

    Full Text Available A bend-free rectangular cross-section OWC device was designed and constructed for studying the effect of inclination on the flow characteristics inside the device. The inclination is meant to reduce reflection of waves and induce higher velocities in the turbine section. Experimental measurements were made in a wave channel where the OWC device was tested. An S-type Pitot tube was used to measure dynamic pressure of air in the turbine section at several inclinations. Particle Image Velocimetry (PIV was also done to study the flow of both air and water in the OWC device. In order to focus solely on primary energy capture, no turbine was installed in the OWC device. The dynamic pressure readings were analysed for suction and compression stages. Water volume fluctuations inside the capture chamber were also recorded and compared for different inclinations. The result was an increase in the velocity of air flowing in the capture chamber and hence a rise in the kinetic energy available to the turbine. It was found from experimental studies that as the angle of inclination reduced, the velocity of air in the turbine section increased. The lower angles also caused higher run-up and larger volume of water into the capture chamber.

  18. Experimental results and analysis on hydrogen combustion

    International Nuclear Information System (INIS)

    Dorofeev, S.B.; Efimenko, A.A.; Kochurko, A.S.; Sidorov, V.P.; Bezmelnitsin, A.V.

    1994-01-01

    The Small-Scale Development Apparatus (SSDA) was constructed to provide a preliminary set of experimental data to characterize the effect of temperature on the ability of hydrogen-air-steam-mixtures to undergo detonations and, equally important, to support design of the larger-scale High-Temperature Combustion Facility (HTCF) by providing a test bed for solution of a number of high-temperature design and operational problems. The SSDA, the central element of which is 10-cm inside diameter, 6.1-m long tubular test vessel designed to permit detonation experiments at temperatures up to 700K, was employed to study self-sustained detonations in gaseous mixtures of hydrogen, air, and steam at temperature between 300K and 650K at a fixed pressure of 0.1 MPa. Detonation cell size measurements provide clear evidence that the effect of hydrogen-air gas mixture temperature, in the range 300K to 650K, is to decrease cell size and, hence, to increase the sensitivity of the mixture to undergo detonations. The effect of steam content, at any given temperature, is to increase the cell size and, thereby, to decrease the sensitivity of stoichiometric hydrogen-air mixtures. The one-dimensional ZND model does a very good job at predicting the overall trends in the cell size data over the range of hydrogen-air-steam mixture compositions and temperature studied in the experiments. Experiments were conducted to measure the rate of hydrogen oxidation in the absence of ignition sources at temperatures of 500K and 650K, for hydrogen-air mixtures of 15% and 50%, and for a mixture of equimolar hydrogen-air and 30% steam at 650K. The rate of hydrogen oxidation was found to be significant at 650K. Reduction of hydrogen concentration by chemical reaction from 50 to 44% hydrogen, and from 15 to 11% hydrogen, were observed on a time frame of minutes. The DeSoete rate equation predicts the 50% experiment very well, but greatly underestimates the reaction rate of the lean mixtures

  19. Experimental results on RPC neutron sensitivity

    Energy Technology Data Exchange (ETDEWEB)

    Abbrescia, M.; Altieri, S.; Baratti, V.; Barnaba, O.; Belli, G.; Bruno, G.; Colaleo, A.; De Vecchi, C.; Guida, R. E-mail: roberto.guida@pv.infn.it; Iaselli, G.; Imbres, E.; Loddo, F.; Maggi, M.; Marangelli, B.; Musitelli, G.; Nardo, R.; Natali, S.; Nuzzo, S.; Pugliese, G.; Ranieri, A.; Ratti, S.; Riccardi, C.; Romano, F.; Torre, P.; Vicini, A.; Vitulo, P

    2003-08-01

    RPC neutron sensitivity has been studied during two tests done with different neutrons energies. In the first test, neutrons from spontaneous fission events of {sup 252}Cf were used (average energy 2 MeV); while in the second test neutrons were produced using a 50 MeV deuteron beam on a 1 cm thick beryllium target (average energy 20 MeV). Preliminary results show that the neutron sensitivity in double gap mode is (0.52{+-}0.03)x10{sup -3} at about 2 MeV and (5.3{+-}0.5)x10{sup -3} at about 20 MeV.

  20. The first results of siliconization on SWIP-RFP device

    International Nuclear Information System (INIS)

    Zhang Peng; Li Qiang; Luo Cuiwen; Li Jieping; Qian Shangjie; Fang Shuiquan; Yi Ping; Xue Jun; Li Kehua; Luo Junlin; Hong Wenyu; Cao Zeng; Zhang Nianman; Wang Quanming; Li Jie; Huang Ming; Zhong Yunze; Zhang Qingchun; Luo Cuixian

    1997-01-01

    The first results of reversed field pinch (RFP) and ultra low safety factor (ULQ) plasma experiments with siliconization on SWIP-RFP device are presented in this paper. The siliconization decreases the impurity concentrations in the plasma and increases the configuration sustainment time. Ion temperature has been estimated with the CV line of the visible light spectra and the broadening of CIII lines in vacuum ultraviolet (VUV) region. The anomalous ion heating as well as the anomalous resistance were observed. (orig.)

  1. Experimental results from the TFTR tokamak

    International Nuclear Information System (INIS)

    Hawryluk, R.J.; Arunasalam, V.; Bell, J.D.

    1986-10-01

    Recent experiments on TFTR have extended the operating regime of TFTR in both ohmic- and neutral-beam-heated discharges. The TFTR tokamak has reached its original machine design specifications (I/sub p/ = 2.5 MA and B/sub T/ = 5.2 T). Initial neutral-beam-heating experiments used up to 6.3 MW of deuterium beams. With the recent installation of two additional beamlines, the power has been increased up to 11 MW. A deuterium pellet injector was used to increase the central density to 2.5 x 10 20 m -3 in high current discharges. At the opposite extreme, by operating at low plasma current (I/sub p/ ∼ 0.8 MA) and low density (anti n/sub e/ ∼ 1 x 10 19 m -3 ), high ion temperatures (9 +- 2 keV) and rotation speeds (7 x 10 5 m/s) have been achieved during injection. In addition, plasma compression experiments have demonstrated acceleration of beam ions from 82 keV to 150 keV, in accord with expectations. The wide operating range of TFTR, together with an extensive set of diagnostics and a flexible control system, has facilitated transport and scaling studies of both ohmic- and neutral-beam-heated discharges. The results of these confinement studies are presented

  2. Overview of recent experimental results on MAST

    International Nuclear Information System (INIS)

    Lloyd, B.; Akers, R.J.; Ahn, J-W.

    2003-01-01

    The low aspect ratio of MAST allows differentiation between different forms of the H-mode threshold scaling. With optimised fuelling (inboard puffing) and magnetic configuration (connected DND) the H-mode power threshold data lie somewhat above ( ∼ x1.7) recent scaling laws. Slight magnetic configuration changes (of the order of the ion Larmor radius) around a connected DND significantly influence H-mode access. H-mode confinement in discharges with low frequency ELMs is generally consistent with the IPB98(y,2) scaling. Strong indications of both particle and energy internal transport barriers have been seen. Normalised beta values β N > 5 have been obtained, approaching the ideal n = 1 no wall external kink stability limit. Sawtooth triggered NTMs (3/2, 2/1) have been observed; numerical modelling of the island evolution reproduces mode behaviour well and confirms the significance of stabilising field curvature effects. Divertor power loading studies, including transient effects (e.g. due to ELMs), show a strong bias of power efflux to the outboard targets where it is more easily handled. ELM energy losses ΔW ELM are less than 4% of the stored energy in all regimes explored so far, but ELM effluxes extending 30cm outside the outboard separatrix have been measured. Toroidally asymmetric divertor biasing resulted in significant broadening of the Dα profile on the biased components and a reduction in the total power to the unbiased components. Halo current magnitudes and asymmetries are generally small compared with conventional tokamaks; recent measurements show that the plasma behaves more as a voltage source than a current source. Initial neutral beam current drive experiments indicate non-inductively driven current values (I NBI ∼ 0.3I p ) comparable with code predictions. (author)

  3. Evaluation of fuel performance with different enrichment degrees for an experimental device

    International Nuclear Information System (INIS)

    Giovedi, Claudia; Pino, Eddy S.; Gomes, Daniel S.; Abe, Alfredo Y.; Silva, Antonio Teixeira e

    2013-01-01

    Evaluation of fuel performance is conventionally carried out using specific codes developed to this aim. The obtained data are confirmed by experimental measurements performed using devices, which are located inside research reactors, projected to simulate reactor conditions under normal operation. Due to the limitations of the available reactor core length for irradiation in research reactors core, fuel rods used to obtain experimental data must present the same characteristics of the real fuel rod, but with a shorter length. Then, in order to compare the obtained results to the expected behavior of the real fuel rod, the experimental fuel rod should be designed with a free volume to fuel volume ratio very closed to the one of the full scale fuel rod. The aim of this paper is to evaluate some parameters and aspects related to the fuel rod behavior in a rod applied to the experimental irradiation device called Nuclear Fuel Irradiation Circuit (CAFE-Mod1) considering two fuel enrichment degrees: a typical commercial PWR enrichment and a value about 4 times higher. This evaluation is carried out by means of an adapted fuel performance code. Some of the parameter evaluated were fuel temperature and fission gas release as function of the fuel enrichment level. The results obtained in this paper were very similar to the ones previously obtained without consider similar free volume between the experimental and the full length fuel rod, regardless of low increases observed for the internal rod pressure and the amount of fission gas released. (author)

  4. Electrical and thermal behavior of unsaturated soils: experimental results

    Science.gov (United States)

    Nouveau, Marie; Grandjean, Gilles; Leroy, Philippe; Philippe, Mickael; Hedri, Estelle; Boukcim, Hassan

    2016-05-01

    When soil is affected by a heat source, some of its properties are modified, and in particular, the electrical resistivity due to changes in water content. As a result, these changes affect the thermal properties of soil, i.e., its thermal conductivity and diffusivity. We experimentally examine the changes in electrical resistivity and thermal conductivity for four soils with different grain size distributions and clay content over a wide range of temperatures, from 20 to 100 °C. This temperature range corresponds to the thermal conditions in the vicinity of a buried high voltage cable or a geothermal system. Experiments were conducted at the field scale, at a geothermal test facility, and in the laboratory using geophysical devices and probing systems. The results show that the electrical resistivity decreases and the thermal conductivity increases with temperature up to a critical temperature depending on soil types. At this critical temperature, the air volume in the pore space increases with temperature, and the resulting electrical resistivity also increases. For higher temperatures , the thermal conductivity increases sharply with temperature up to a second temperature limit. Beyond it, the thermal conductivity drops drastically. This limit corresponds to the temperature at which most of the water evaporates from the soil pore space. Once the evaporation is completed, the thermal conductivity stabilizes. To explain these experimental results, we modeled the electrical resistivity variations with temperature and water content in the temperature range 20 - 100°C, showing that two critical temperatures influence the main processes occurring during heating at temperatures below 100 °C.

  5. Experimental study of membrane pump for plasma devices

    International Nuclear Information System (INIS)

    Suzuki, Hajime; Ohyabu, Nobuyoshi; Nakamura, Yukio; Sagara, Akio; Motojima, Osamu; Livshits, A.; Notkin, M.; Busnyuk, A.; Komatsu, Kazuyuki

    1998-01-01

    Recycling control is a key to improve fusion plasma performance. The membrane pump has potential advantages for hydrogen pumping in fusion devices. However, there are unsolved issues for using membrane pump in LHD (Large Helical Device). The first issue is characteristics of the membrane pump under high incident hydrogen atom flux. The second issue is relationship between the surface condition and the pumping efficiency. Impurities from plasma may change the surface condition of the membrane. In order to solve these issues, a membrane pump system was fabricated and installed in a linear plasma device at NIFS (National Institute for Fusion Science). The membrane pump was successfully operated. (author)

  6. Campaign to gather medical devices containing radium: results

    International Nuclear Information System (INIS)

    Pierre, J.P.; Vidal, J.P.; Martin, J.C.; Pasquier, J.L.

    2002-01-01

    Campaign to gather medical devices containing radium: results. On December 1, 1999, at the request of the French Health Ministry, OPRI and ANDRA launched a campaign to gather medical devices containing radium, formerly used in brachytherapy. This campaign addressed a public health issue because of the risks actually involved in a careless handling of these objects. Moreover the growing number of reported scattered radium medical devices in the last few years reinforced the necessity of the campaign. The gathering was initiated by a call of the owners (hospitals, caring centers, retired doctors or their heirs) to a toll free number. OPRI or ANDRA then appreciated the situation urgency. Priority was given to private people because most of them did not have suitable storage facilities. OPRI teams operated according a strict protocol guaranteeing their own safety, proper procedures and compliance with transport regulations for radioactive materials. 517 objects amounting to an activity of 1.32 x 10 11 Bq have been gathered in 90 operations. Properly packaged they were transported to and safely stored at the CEA Saclay site before their permanent storage in the ANDRA facilities. (author)

  7. A novel device for the occlusion of left atrial appendage: an experimental study in canine models

    International Nuclear Information System (INIS)

    Yang Zhihong; Qin Yongwen; Wu Hong; Hu Jianqiang; Wang Shengqiang; Ding Zhongru; Liu Zongjun

    2011-01-01

    Objective: To evaluate the feasibility, safety and biocompatibility of a novel device designed by the authors for the occlusion of left atrial appendage (LAA) in canine models. Methods: The occlusion of LAA was performed in 20 experimental dogs by using a novel LAA occluder, which was delivered to the LAA through a transseptal catheter. During the period of 2 weeks to 6 months after the procedure, the dogs were kept under observation for the device healing, migration, perforation and the formation of thrombus. Both scanning electron microscope (SEM) and transmission electron microscope (TEM) were used to examine the endothelial growth on the surface of the occluder and the structure of the endothelial cells. Results: Of the total 20 dogs, the novel device was successfully implanted in 14. The LAA was occluded completely in 13 dogs. No mobile thrombi caused by the implantation procedure were observed. Endothelialization of the atrium-facing surface was observed at one month after the procedure, and the surface was completely covered with endothelial cells at 3 months after the treatment, which was confirmed by gross, histological and SEM examinations. TEM examination showed that the structure of endothelial cells, the mitochondrion and sarcomere of atrial cardiocyte were all normal. Gross and light microscopic examination of the kidney, lung spleen and liver showed that there was no evidence of embolism or infarction. Conclusion: The novel device is safe and feasible for the occlusion of the LAA in experimental dogs. Further study is needed to observe its long-term safety. (authors)

  8. Experimental arrangement to measure dispersion in optical fiber devices

    Energy Technology Data Exchange (ETDEWEB)

    Armas Rivera, Ivan [Benemerita Universidad Autonoma de Puebla, Facultad de Ciencias de la Electronica (Mexico); Beltran Perez, Georgina; Castillo Mixcoatl, Juan; Munoz Aguirre, Severino [Benemerita Universidad Autonoma de Puebla, Facultad de Ciencias Fisico Matematicas (Mexico); Zaca Moran, Placido, E-mail: ivan_rr1@hotmail.com [Benemerita Universidad Autonoma de Puebla, Fisicoquimica de Materiales ICUAP (Mexico)

    2011-01-01

    Dispersion is a quite important parameter in systems based on optical fiber, especially in pulsed emission lasers, where the temporal width is affected by such parameter. Therefore, it is necessary to consider the dispersion provoked by each component in the cavity. There are various experimental interferometric arrangements to evaluate this parameter. Generally, these systems modify the wavelength to obtain information about the n({lambda}) dependency, which is contained in the interferogram phase. However, this makes the system quite slow and it requires tunable and narrow bandwidth laser sources. In the present work, results obtained from an arrangement based on Mach-Zehnder interferometer where one of the arms is the optical fiber under study, while the reference one is air, are presented. In order to determine the n({lambda}) dependency, a wide spectrum light source was used in the wavelength range of interest. The phase information was evaluated from the interferometric signal measured by an optical spectrum analyzer.

  9. Experimental arrangement to measure dispersion in optical fiber devices

    International Nuclear Information System (INIS)

    Armas Rivera, Ivan; Beltran Perez, Georgina; Castillo Mixcoatl, Juan; Munoz Aguirre, Severino; Zaca Moran, Placido

    2011-01-01

    Dispersion is a quite important parameter in systems based on optical fiber, especially in pulsed emission lasers, where the temporal width is affected by such parameter. Therefore, it is necessary to consider the dispersion provoked by each component in the cavity. There are various experimental interferometric arrangements to evaluate this parameter. Generally, these systems modify the wavelength to obtain information about the n(λ) dependency, which is contained in the interferogram phase. However, this makes the system quite slow and it requires tunable and narrow bandwidth laser sources. In the present work, results obtained from an arrangement based on Mach-Zehnder interferometer where one of the arms is the optical fiber under study, while the reference one is air, are presented. In order to determine the n(λ) dependency, a wide spectrum light source was used in the wavelength range of interest. The phase information was evaluated from the interferometric signal measured by an optical spectrum analyzer.

  10. Experimental and simulated control of lift using trailing edge devices

    Science.gov (United States)

    Cooperman, A.; Blaylock, M.; van Dam, C. P.

    2014-12-01

    Two active aerodynamic load control (AALC) devices coupled with a control algorithm are shown to decrease the change in lift force experienced by an airfoil during a change in freestream velocity. Microtabs are small (1% chord) surfaces deployed perpendicular to an airfoil, while microjets are pneumatic jets with flow perpendicular to the surface of the airfoil near the trailing edge. Both devices are capable of producing a rapid change in an airfoil's lift coefficient. A control algorithm for microtabs has been tested in a wind tunnel using a modified S819 airfoil, and a microjet control algorithm has been simulated for a NACA 0012 airfoil using OVERFLOW. In both cases, the AALC devices have shown the ability to mitigate the changes in lift during a gust.

  11. Experimental and simulated control of lift using trailing edge devices

    International Nuclear Information System (INIS)

    Cooperman, A; Blaylock, M; Van Dam, C P

    2014-01-01

    Two active aerodynamic load control (AALC) devices coupled with a control algorithm are shown to decrease the change in lift force experienced by an airfoil during a change in freestream velocity. Microtabs are small (1% chord) surfaces deployed perpendicular to an airfoil, while microjets are pneumatic jets with flow perpendicular to the surface of the airfoil near the trailing edge. Both devices are capable of producing a rapid change in an airfoil's lift coefficient. A control algorithm for microtabs has been tested in a wind tunnel using a modified S819 airfoil, and a microjet control algorithm has been simulated for a NACA 0012 airfoil using OVERFLOW. In both cases, the AALC devices have shown the ability to mitigate the changes in lift during a gust

  12. Experimental Research of a New Wave Energy Conversion Device

    Science.gov (United States)

    Lu, Zhongyue; Shang, Jianzhong; Luo, Zirong; Sun, Chongfei; Chen, Gewei

    2018-01-01

    With the increasing tension of contemporary social energy, the development and utilization of renewable energy has become an important development direction. As an important part of renewable energy, wave energy has the characteristics of green environmental protection and abundant reserves, attracting more investment and research. For small marine equipment energy supply problem, this paper puts forward a micro wave energy conversion device as the basic of heaving motion of waves in the ocean. This paper designed a new type of power output device can solve the micro wave energy conversion problem.

  13. Numerical and experimental investigation of wave dynamics on a land-fixed OWC device

    International Nuclear Information System (INIS)

    Ning, De-Zhi; Wang, Rong-Quan; Gou, Ying; Zhao, Ming; Teng, Bin

    2016-01-01

    An Oscillating Water Column (OWC) Wave Energy Converter (WEC) is a device that converts the energy of ocean waves to electrical energy. When an OWC is designed, both its energy efficiency and the wave loads on it should be considered. Most attentions have been paid to the energy efficiency of an OWC device in the past several decades. In the present study, the fully nonlinear numerical wave model developed by Ning et al. (2015) [1] is extended to simulate the dynamic wave forces on the land-fixed OWC device by using the acceleration potential method, and the experimental tests are also carried out. The comparisons between numerical results and experimental data are performed. Then the effects of wave conditions and chamber geometry on the wave force on the front wall of the chamber are investigated. The results indicate that the total wave force decreases with the increase of the wavelength and increases with the increase of the incident wave height. The wave force is also strongly influenced by the opening ratio, i.e., in the low-frequency region, the larger the opening ratio, the smaller the wave force and it shows an opposite tendency in the high-frequency region. - Highlights: • The wave dynamics on a land-fixed OWC device is numerically and experimentally studied. • The largest wave pressure occurs on the outside of the front wall on the free surface under the action of the wave crest. • The total horizontal wave load on the front wall decreases with the increase of the wavelength. • The opening ratio greatly influences the wave force on the front wall.

  14. Comparison of CFD simulations with experimental Jet Erosion Tests results

    OpenAIRE

    Mercier, F.; Bonelli, S.; Pinettes, P.; Golay, F.; Anselmet, F.; Philippe, P.

    2014-01-01

    The Jet Erosion Test (JET) is an experimental device increasingly used to quantify the resistance of soils to erosion. This resistance is characterised by two geotechnical parameters: the critical shear stress and the erosion coefficient. The JET interpretation model of Hanson and Cook (2004) provides an estimation of these erosion parameters. But Hanson's model is simplified, semi-empirical and several assumed hypotheses can be discussed. Our aim is to determine the relevance of the JET inte...

  15. Initial results from the Tokapole-II poloidal divertor device

    International Nuclear Information System (INIS)

    Biddle, A.P.; Dexter, R.N.; Groebner, R.J.; Holly, D.J.; Lipschultz, B.; Phillips, M.W.; Prager, S.C.; Sprott, J.C.

    1979-01-01

    The latest in a series of internal-ring devices, called Tokapole II, has recently begun operation at the University of Wisconsin. Its purpose is to permit the study of the production and confinement of hot, dense plasmas in either a toroidal octupole (with or without toroidal field) or a tokamak with a four-node poloidal divertor. The characteristics of the device and the results of its initial operation are described here. Quantitative measurements of impurity concentration and radiated power have been made. Poloidal divertor equilibria of square and dee shapes have been produced, and an axisymmetric instability has been observed with the inverse dee. Electron cyclotron resonance heating is used to initiate the breakdown near the axis and to control the initial influx of impurities. A 2-MW RF source at the second harmonic of the ion cyclotron frequency is available and has been used to double the ion temperature when operated at low power with an unoptimized antenna. Initial results of operation as a pure octupole with poloidal Ohmic heating suggest a tokamak-like scaling of density (n proportional to Bsub(p)) and confinement time (tau proportional to n). (author)

  16. Study on collection efficiency of fission products by spray: Experimental device and modelling

    Energy Technology Data Exchange (ETDEWEB)

    Ducret, D.; Roblot, D.; Vendel, J. [Institut de Protection et de Surete Nucleaire, Gif-Sur-Yvette (France); Billarand, Y. [ECCO Pharmacie et Chimie, Neuilly (France)

    1997-08-01

    Consequences of an hypothetical overheating reactor accident in nuclear power plants can be limited by spraying cold water drops into containment building. The spray reduces the pressure and the temperature levels by condensation of steam and leads to the washout of fission products (aerosols and gaseous iodine). The present study includes a large program devoted to the evaluation of realistic washout rates. An experimental device (named CARAIDAS) was designed and built in order to determine the collection efficiency of aerosols and iodine absorption by drops with representative conditions of post-accident atmosphere. This experimental device is presented in the paper and more particularly: (1) the experimental enclosure in which representative thermodynamic conditions can be achieved, (2) the monosized drops generator, the drops diameter measurement and the drops collector, (3) the cesium iodide aerosols generator and the aerosols measurements. Modelling of steam condensation on drops aerosols collection and iodine absorption are described. First experimental and code results on drops and aerosols behaviour are compared. 8 refs., 18 figs.

  17. Design of an experimental device dedicated to the measurement of spallation reactions; Mise au point d'un dispositif experimental pour des mesures exclusives des reactions de spallation

    Energy Technology Data Exchange (ETDEWEB)

    Lafriakh, A

    2005-12-15

    Spallation mechanisms are not yet completely understood, especially because of the difficulty of experimentally disentangling the effects of the different steps of the reaction. In order to understand these mechanisms, we have developed a new experimental device able to perform inclusive measurements. We propose a detection system based on a combination of ionization chambers and proportional counters and on a wall of plastic scintillators to measure light charged particles. In particular the detection of light charged particles is described in detail. In order to validate our device, we have compared our preliminary results obtained on the Fe{sup 56} + p system at 1 GeV/u with inclusive measurements previously obtained at the FRS spectrometer of the GSI facility. A comparison of charge differential cross section shows reasonable agreement. However, our new device allowed extension of those measurements down to Z = 1 and Z = 2. These cross sections are important for material damage studies. Taking into account our error brackets, the evolution of mean longitudinal velocities with respect to residue masses is comparable to that obtained at the FRS. These first results, although preliminary, allow us to validate our experimental device. It is now possible to exploit the strong points of our exclusive measurements, namely correlations between different measured observables. Finally, experimental problems encountered will be taken into account in the future experimental programs, in order to ensure the best measurements conditions.

  18. Experimental animal study of a novel radiofrequency endovascular occlusion device.

    Science.gov (United States)

    Zacharoulis, Dimitris; Lazoura, Olga; Rountas, Christos; Katsimboulas, Michael; Mantzianas, George; Tzovaras, George; Habib, Nagy

    2011-07-01

    The purpose of this study was to present a radiofrequency (RF) endovascular occlusion device (ie, Habib VesCoag Catheter; EMcision Ltd, London, UK) and to evaluate safety and efficacy of the device for complete occlusion of normal porcine vessels. The study included 20 pigs. In each pig, a segmental branch of the right hepatic artery, a branch of the splenic artery, and a branch of one of the renal arteries were catheterized. A single or multiple applications of RF energy were performed until vessel occlusion was achieved. Fifteen days later, angiography was repeated to assess vessel patency. The vessels were then excised for pathological analysis. Vessels 2.5 to 6 mm in diameter were treated. Complete occlusion with a single attempt was achieved using a mean amount of energy of 110.67 J in vessels 2.5 to 3 mm, 111.67 J in vessels 3.5 to 4 mm, and 116.63 J in vessels 5 to 6 mm in diameter and was confirmed by angiography at the 15-day follow-up. Vascular occlusion can be effectively and safely achieved by endovascular application of RF energy to normal porcine arteries using the Habib VesCoag catheter. Copyright © 2011 Elsevier Inc. All rights reserved.

  19. Preliminary Results Of A 600 Joules Small Plasma Focus Device

    International Nuclear Information System (INIS)

    Lee, S. H.; Yap, S. L.; Wong, C. S.

    2009-01-01

    Preliminary results of a 600 J (3.7 μF, 18 kV) Mather type plasma focus device operated at low pressure will be presented. The discharge is formed between a solid anode with length of 6 cm and six symmetrically and coaxially arranged cathode rods of same lengths. The cathode base is profiled in a knife-edge design and a set of coaxial plasma gun are attached to it in order to initiate the breakdown and enhance the current sheath formation. The experiments have been performed in argon gas under a low pressure condition of several microbars. The discharge current and the voltage across the electrodes during the discharge are measured with high voltage probe and current coil. The current and voltage characteristics are used to determine the possible range of operating pressure that gives good focusing action. At a narrow pressure regime of 9.0±0.5 μbar, focusing action is observed with good reproducibility. Preliminary result of ion beam energy is presented. More work will be carried out to investigate the radiation output.

  20. Design and Experimental Characterization of a Vibration Energy Harvesting Device for Rotational Systems

    Directory of Open Access Journals (Sweden)

    Lutao Yan

    2013-01-01

    Full Text Available This paper presents a new vibration based electromagnetic power generator to transfer energy from stationary to rotating equipment, which can be a new attempt to substitute slip ring in rotational systems. The natural frequencies and modes are simulated in order to have a maximum and steady power output from the device. Parameters such as piezoelectric disk location and relative motion direction of the magnet are theoretically and experimentally analyzed. The results show that the position that is close to the fixed end of the cantilever and the relative motion along the long side gives higher power output. Moreover, the capability of the energy harvester to extract power from lower energy environment is experimentally validated. The voltage and power output are measured at different excitation frequencies.

  1. First results with prototype ISIS devices for ILC vertex detector

    International Nuclear Information System (INIS)

    Damerell, C.; Zhang, Z.; Gao, R.; John John, Jaya; Li, Y.; Nomerotski, A.; Holland, A.; Seabroke, G.; Havranek, M.; Stefanov, K.; Kar-Roy, A.; Bell, R.; Burt, D.; Pool, P.

    2010-01-01

    The vertex detectors at the International Linear Collider (ILC) (there will be two of them, one for each of two general purpose detectors) will certainly be built with silicon pixel detectors, either monolithic or perhaps vertically integrated. However, beyond this general statement, there is a wide range of options supported by active R and D programmes all over the world. Pixel-based vertex detectors build on the experience at the SLAC large detector (SLD) operating at the SLAC linear collider (SLC), where a 307 Mpixel detector permitted the highest physics performance at LEP or SLC. For ILC, machine conditions demand much faster readout than at SLC, something like 20 time slices during the 1 ms bunch train. The approach of the image sensor with in-situ storage (ISIS) is unique in offering this capability while avoiding the undesirable requirement of 'pulsed power'. First results from a prototype device that approaches the pixel size of 20 μm square, needed for physics, are reported. The dimensional challenge is met by using a 0.18 μm imaging CMOS process, instead of a conventional CCD process.

  2. First results with prototype ISIS devices for ILC vertex detector

    Energy Technology Data Exchange (ETDEWEB)

    Damerell, C., E-mail: c.damerell@rl.ac.u [RAL, Oxon OX11 0QX (United Kingdom); Zhang, Z. [RAL, Oxon OX11 0QX (United Kingdom); Gao, R.; John John, Jaya; Li, Y.; Nomerotski, A. [Oxford U (United Kingdom); Holland, A.; Seabroke, G. [Centre for Electronic Imaging, Open U (United Kingdom); Havranek, M. [Czech Technical University in Prague (Czech Republic); Stefanov, K. [Sentec Ltd, Cambridge (United Kingdom); Kar-Roy, A. [Jazz Semiconductors, California (United States); Bell, R.; Burt, D.; Pool, P. [e2V Technologies, Chelmsford (United Kingdom)

    2010-12-11

    The vertex detectors at the International Linear Collider (ILC) (there will be two of them, one for each of two general purpose detectors) will certainly be built with silicon pixel detectors, either monolithic or perhaps vertically integrated. However, beyond this general statement, there is a wide range of options supported by active R and D programmes all over the world. Pixel-based vertex detectors build on the experience at the SLAC large detector (SLD) operating at the SLAC linear collider (SLC), where a 307 Mpixel detector permitted the highest physics performance at LEP or SLC. For ILC, machine conditions demand much faster readout than at SLC, something like 20 time slices during the 1 ms bunch train. The approach of the image sensor with in-situ storage (ISIS) is unique in offering this capability while avoiding the undesirable requirement of 'pulsed power'. First results from a prototype device that approaches the pixel size of 20 {mu}m square, needed for physics, are reported. The dimensional challenge is met by using a 0.18 {mu}m imaging CMOS process, instead of a conventional CCD process.

  3. Technological parameter and experimental set-up influences on latch-up triggering level in bulk CMOS device

    International Nuclear Information System (INIS)

    Dubuc, J.P.; Azais, B.; Murcia, M. de

    1994-01-01

    This paper deals with experimental and simulation results on latch-up triggered by an electrical or X-rays pulse in CMOS/bulk devices. Test condition influences as well as the great importance of process parameters on latch-up immunity are emphasized. (author). 10 refs., 19 figs., 1 tab

  4. Fuel pins irradiation: experimental devices and analytical behaviour

    International Nuclear Information System (INIS)

    Lemaignan, C.

    1996-01-01

    In this text we present the general characteristics of adapted irradiation loops in research reactors and the main results that we can expected with these loops in the behaviour field of PWR and LMFBR fuels( fuel densification, fuel cladding interactions, fission products release, reactor accidents)

  5. Master-Slave synchronization of robot manipulators: experimental results

    NARCIS (Netherlands)

    Bondhus, A.K.; Pettersen, K.Y.; Nijmeijer, H.

    2005-01-01

    This paper presents experimental results for master-slave synchronization of two robot manipulators using a recently developed observer-controller scheme. The paper aims to investigate the value and the limitations of the theory. In particular, the theoretical result of uniform ultimate boundedness

  6. Sodium fires. Progress achieved in research and experimental results

    International Nuclear Information System (INIS)

    Malet, J.C.; Duverger de Cuy, G.; Casselman, C.; Charpenel, J.; Natta, M.; Devillers, C.

    1979-08-01

    This paper describes the sodium fire programs undertaken by the CEA's Nuclear Safety Department. Experimental results concerning sodium ignition and combustion, sodium fire suppression, sodium aerosol filtration and sodium-concrete contact reactions are given and the applications of these results in the Super-Phenix reactor is discussed

  7. First result on biased CMOS MAPs-on-diamond devices

    Energy Technology Data Exchange (ETDEWEB)

    Kanxheri, K., E-mail: keida.kanxheri@pg.infn.it [Università degli Studi di Perugia, Perugia (Italy); INFN Perugia, Perugia (Italy); Citroni, M.; Fanetti, S. [LENS Firenze, Florence (Italy); Lagomarsino, S. [Università degli Studi di Firenze, Florence (Italy); INFN Firenze, Pisa (Italy); Morozzi, A. [Università degli Studi di Perugia, Perugia (Italy); INFN Perugia, Perugia (Italy); Parrini, G. [Università degli Studi di Firenze, Florence (Italy); Passeri, D. [Università degli Studi di Perugia, Perugia (Italy); INFN Perugia, Perugia (Italy); Sciortino, S. [Università degli Studi di Firenze, Florence (Italy); INFN Firenze, Pisa (Italy); Servoli, L. [INFN Perugia, Perugia (Italy)

    2015-10-01

    Recently a new type of device, the MAPS-on-diamond, obtained bonding a thinned to 25 μm CMOS Monolithic Active Pixel Sensor to a standard 500 μm pCVD diamond substrate, has been proposed and fabricated, allowing a highly segmented readout (10×10 μm pixel size) of the signal produced in the diamond substrate. The bonding between the two materials has been obtained using a new laser technique to deliver the needed energy at the interface. A biasing scheme has been adopted to polarize the diamond substrate to allow the charge transport inside the diamond without disrupting the functionalities of the CMOS Monolithic Active Pixel Sensor. The main concept of this class of devices is the capability of the charges generated in the diamond by ionizing radiation to cross the silicon–diamond interface and to be collected by the MAPS photodiodes. In this work we demonstrate that such passage occurs and measure its overall efficiency. This study has been carried out first calibrating the CMOS MAPS with monochromatic X-rays, and then testing the device with charged particles (electrons) either with and without biasing the diamond substrate, to compare the amount of signal collected.

  8. Closed Loop Two-Phase Thermosyphon of Small Dimensions: a Review of the Experimental Results

    Science.gov (United States)

    Franco, Alessandro; Filippeschi, Sauro

    2012-06-01

    A bibliographical review on the heat and mass transfer in gravity assisted Closed Loop Two Phase Thermosyphons (CLTPT) with channels having a hydraulic diameter of the order of some millimetres and input power below 1 kW is proposed. The available experimental works in the literature are critically analysed in order to highlight the main results and the correlation between mass flow rate and heat input in natural circulation loops. A comparison of different experimental apparatuses and results is made. It is observed that the results are very different among them and in many cases the experimental data disagree with the conventional theory developed for an imposed flow rate. The paper analyses the main differences among the experimental devices and try to understand these disagreements. From the present analysis it is evident that further systematic studies are required to generate a meaningful body of knowledge of the heat and mass transport mechanism in these devices for practical applications in cooling devices or energy systems.

  9. Constructing experimental devices for half-ton synthesis of gadolinium-loaded liquid scintillator and its performance

    Science.gov (United States)

    Park, Young Seo; Jang, Yeong Min; Joo, Kyung Kwang

    2018-04-01

    This paper describes in brief features of various experimental devices constructed for half-ton synthesis of gadolinium(Gd)-loaded liquid scintillator (GdLS) and also includes the performances and detailed chemical and physical results of a 0.5% high-concentration GdLS. Various feasibility studies on useful apparatus used for loading Gd into solvents have been carried out. The transmittance, Gd concentration, density, light yield, and moisture content were measured for quality control. We show that with the help of adequate automated experimental devices and tools, it is possible to perform ton scale synthesis of GdLS at moderate laboratory scale without difficulty. The synthesized GdLS was satisfactory to meet chemical, optical, and physical properties and various safety requirements. These synthesizing devices can be expanded into massive scale next-generation neutrino experiments of several hundred tons.

  10. Divertors for Helical Devices: Concepts, Plans, Results, and Problems

    International Nuclear Information System (INIS)

    Koenig, R.; Grigull, P.; McCormick, K.

    2004-01-01

    With Large Helical Device (LHD) and Wendelstein 7-X (W7-X), the development of helical devices is now taking a large step forward on the path to a steady-state fusion reactor. Important issues that need to be settled in these machines are particle flux and heat control and the impact of divertors on plasma performance in future continuously burning fusion plasmas. The divertor concepts that will initially be explored in these large machines were prepared in smaller-scale devices like Heliotron E, Compact Helical System (CHS), and Wendelstein 7-AS (W7-AS). While advanced divertor scenarios relevant for W7-X were already studied in W7-AS, other smaller-scale experiments like Heliotron-J, CHS, and National Compact Stellarator Experiment will be used for the further development of divertor concepts. The two divertor configurations that are being investigated are the helical and the island divertor, as well as the local island divertor, which was successfully demonstrated on CHS and just went into operation on LHD. At present, on its route to a fully closed helical divertor, LHD operates in an open helical divertor configuration. W7-X will be equipped right from the start with an actively cooled discrete island divertor that will allow quasi-continuous operation. The divertor design is very similar to the one explored on W7-AS. For sufficiently large island sizes and not too long field line connection lengths, this divertor gives access to a partially detached quasi-steady-state operating scenario in a newly found high-density H-mode operating regime, which benefits from high energy and low impurity confinement times, with edge radiation levels of up to 90% and sufficient neutral compression in the subdivertor region (>10) for active pumping. The basic physics of the different divertor concepts and associated implementation problems, like asymmetries due to drifts, accessibility of essential operating scenarios, toroidal asymmetries due to symmetry breaking error fields

  11. A numerical analysis and experimental demonstration of a low degradation conductive bridge resistive memory device

    KAUST Repository

    Berco, Dan

    2017-10-23

    This study investigates a low degradation metal-ion conductive bridge RAM (CBRAM) structure. The structure is based on placing a diffusion blocking layer (DBL) between the device\\'s top electrode (TE) and the resistive switching layer (RSL), unlike conventional CBRAMs, where the TE serves as a supply reservoir for metallic species diffusing into the RSL to form a conductive filament (CF) and is kept in direct contact with the RSL. The properties of a conventional CBRAM structure (Cu/HfO2/TiN), having a Cu TE, 10 nm HfO2 RSL, and a TiN bottom electrode, are compared with a 2 nm TaN DBL incorporating structure (Cu/TaN/HfO2/TiN) for 103 programming and erase simulation cycles. The low and high resistive state values for each cycle are calculated and the analysis reveals that adding the DBL yields lower degradation. In addition, the 2D distribution plots of oxygen vacancies, O ions, and Cu species within the RSL indicate that oxidation occurring in the DBL-RSL interface results in the formation of a sub-stoichiometric tantalum oxynitride with higher blocking capabilities that suppresses further Cu insertion beyond an initial CF formation phase, as well as CF lateral widening during cycling. The higher endurance of the structure with DBL may thus be attributed to the relatively low amount of Cu migrating into the RSL during the initial CF formation. Furthermore, this isomorphic CF displays similar cycling behavior to neural ionic channels. The results of numerical analysis show a good match to experimental measurements of similar device structures as well

  12. Experimental results on photon-photon interactions at Adone

    International Nuclear Information System (INIS)

    Baldini Celio, R.; Capon, G.; Fabbro, R. del; Santis, P. de; Grilli, M.; Iarocci, E.; Mencuccini, C.; Murtas, G.P.; Spinetti, M.; Valente, V.; Bacci, C.; Zorzi, C. de; Penso, G.; Stella, B.

    1979-01-01

    Experimental results for the reactions e + e - →e + e - +X are presented for X=e + e - ,μ + μ - ,π + π - ,eta'. A tagging technique has been used to detect final electrons and positrons. A QED test is performed and an upper limit of 20 keV is derived for the partial width GAMMA(eta'→γγ). (Auth.)

  13. First experimental results on CMOS Integrated Nickel Electroplated Resonators

    DEFF Research Database (Denmark)

    Yalcinkaya, Arda Deniz; Hansen, Ole

    2004-01-01

    This paper presents experimental results on MEMS metallic add-on post-fabrication effects on complementary metal oxide semiconductor (CMOS) transistors. Two versions of add-on processing, that use either e-beam evaporation or magnetron sputtering, are compared through investigation of the electri...

  14. Oscillation experiments on Cesar and Marius - Experimental devices and measurement techniques

    International Nuclear Information System (INIS)

    Brunet, Max; Guerange, Jacques; Morier, Francis; Tonolli, Jacky

    1969-02-01

    An original method of measurement of effective cross sections of fissile materials has been developed by the CEA: a central fuel element of a critical experimental reactor is replaced by a sample containing the material to be studied. The replacement technique is based on oscillating the fuel load of the central channel. Signals are measured which are proportional to reactivity variation and to neutron density disturbance at the vicinity of the central channel, these variation and disturbance being produced by the sample oscillation. Measurements have been performed on experimental reactors (Minerve in Fontenay-aux-Roses, and Cesar and Marius in Cadarache). The authors herein describe the experimental devices and measurement techniques implemented in Marius and Cesar. In a first part, they describe the experimental devices which have been used during the three measurement campaigns (between 1965 and 1967). They report the study of measurement accuracies, and of some problems related to the use of the local detector [fr

  15. Quantum Hall resistance standard in graphene devices under relaxed experimental conditions

    Science.gov (United States)

    Schopfer, F.; Ribeiro-Palau, R.; Lafont, F.; Brun-Picard, J.; Kazazis, D.; Michon, A.; Cheynis, F.; Couturaud, O.; Consejo, C.; Jouault, B.; Poirier, W.

    Large-area and high-quality graphene devices synthesized by CVD on SiC are used to develop reliable electrical resistance standards, based on the quantum Hall effect (QHE), with state-of-the-art accuracy of 1x10-9 and under an extended range of experimental conditions of magnetic field (down to 3.5 T), temperature (up to 10 K) or current (up to 0.5 mA). These conditions are much relaxed as compared to what is required by GaAs/AlGaAs standards and will enable to broaden the use of the primary quantum electrical standards to the benefit of Science and Industry for electrical measurements. Furthermore, by comparison of these graphene devices with GaAs/AlGaAs standards, we demonstrate the universality of the QHE within an ultimate uncertainty of 8.2x10-11. This suggests the exact relation of the quantized Hall resistance with the Planck constant and the electron charge, which is crucial for the new SI to be based on fixing such fundamental constants. These results show that graphene realizes its promises and demonstrates its superiority over other materials for a demanding application. Nature Nanotech. 10, 965-971, 2015, Nature Commun. 6, 6806, 2015

  16. Recent experimental results on Coherent Pion production in neutrino interactions

    Energy Technology Data Exchange (ETDEWEB)

    Camilleri, L. [Columbia University, Nevis Labs Irvington on Hudson, New York 10533 (United States)

    2012-08-15

    Recent experimental results on charged current ({pi}{sup +}) coherent production by KEK and SciBooNE and neutral current ({pi}{sup 0}) production by MiniBooNE, SciBooNE and NOMAD will be discussed. The NOMAD results are at an average neutrino energy of 25 GeV whereas the energies of the other experiments are in an average energy range of 1-2 GeV. A comparison with some theoretical models will be presented.

  17. New experimental device for high-temperature normal spectral emissivity measurements of coatings

    International Nuclear Information System (INIS)

    Honnerová, Petra; Martan, Jiří; Kučera, Martin; Honner, Milan; Hameury, Jacques

    2014-01-01

    A new experimental device for normal spectral emissivity measurements of coatings in the infrared spectral range from 1.38 μm to 26 μm and in the temperature range from 550 K to 1250 K is presented. A Fourier transform infrared spectrometer (FTIR) is used for the detection of sample and blackbody spectral radiation. Sample heating is achieved by a fiber laser with a scanning head. Surface temperature is measured by two methods. The first method uses an infrared camera and a reference coating with known effective emissivity, the second method is based on the combination of Christiansen wavelength with contact and noncontact surface temperature measurement. Application of the method is shown on the example of a high-temperature high-emissivity coating. Experimental results obtained with this apparatus are compared with the results performed by a direct method of Laboratoire National d’Essais (LNE) in France. The differences in the spectra are analyzed. (paper)

  18. Analysis and experimental study on the effect of a resonant tube on the performance of acoustic levitation devices

    Science.gov (United States)

    Jiang, Hai; Liu, Jianfang; Lv, Qingqing; Gu, Shoudong; Jiao, Xiaoyang; Li, Minjiao; Zhang, Shasha

    2016-09-01

    The influence of a resonant tube on the performance of acoustic standing wave-based levitation device (acoustic levitation device hereinafter) is studied by analyzing the acoustic pressure and levitation force of four types of acoustic levitation devices without a resonance tube and with resonance tubes of different radii R using ANSYS and MATLAB. Introducing a resonance tube either enhances or weakens the levitation strength of acoustic levitation device, depending on the resonance tube radii. Specifically, the levitation force is improved to a maximum degree when the resonance tube radius is slightly larger than the size of the reflector end face. Furthermore, the stability of acoustic levitation device is improved to a maximum degree by introducing a resonance tube of R=1.023λ. The experimental platform and levitation force measurement system of the acoustic levitation device with concave-end-face-type emitter and reflector are developed, and the test of suspended matters and liquid drops is conducted. Results show that the Φ6.5-mm steel ball is suspended easily when the resonance tube radius is 1.023λ, and the Φ5.5-mm steel ball cannot be suspended when the resonance tube radius is 1.251λ. The levitation capability of the original acoustic levitation device without a resonance tube is weakened when a resonance tube of R=1.251λ is applied. These results are consistent with the ANSYS simulation results. The levitation time of the liquid droplet with a resonance tube of R=1.023λ is longer than without a resonance tube. This result is also supported by the MATLAB simulation results. Therefore, the performance of acoustic levitation device can be improved by introducing a resonant tube with an appropriate radius.

  19. Analysis and experimental study on the effect of a resonant tube on the performance of acoustic levitation devices

    Directory of Open Access Journals (Sweden)

    Hai Jiang

    2016-09-01

    Full Text Available The influence of a resonant tube on the performance of acoustic standing wave-based levitation device (acoustic levitation device hereinafter is studied by analyzing the acoustic pressure and levitation force of four types of acoustic levitation devices without a resonance tube and with resonance tubes of different radii R using ANSYS and MATLAB. Introducing a resonance tube either enhances or weakens the levitation strength of acoustic levitation device, depending on the resonance tube radii. Specifically, the levitation force is improved to a maximum degree when the resonance tube radius is slightly larger than the size of the reflector end face. Furthermore, the stability of acoustic levitation device is improved to a maximum degree by introducing a resonance tube of R=1.023λ. The experimental platform and levitation force measurement system of the acoustic levitation device with concave-end-face-type emitter and reflector are developed, and the test of suspended matters and liquid drops is conducted. Results show that the Φ6.5-mm steel ball is suspended easily when the resonance tube radius is 1.023λ, and the Φ5.5-mm steel ball cannot be suspended when the resonance tube radius is 1.251λ. The levitation capability of the original acoustic levitation device without a resonance tube is weakened when a resonance tube of R=1.251λ is applied. These results are consistent with the ANSYS simulation results. The levitation time of the liquid droplet with a resonance tube of R=1.023λ is longer than without a resonance tube. This result is also supported by the MATLAB simulation results. Therefore, the performance of acoustic levitation device can be improved by introducing a resonant tube with an appropriate radius.

  20. Feedback control of a cupola - concepts and experimental results

    Energy Technology Data Exchange (ETDEWEB)

    Moore, K.L. [Idaho State Univ., Pocatello, ID (United States); Abdelrahman, M.A. [Tenn. Technological Univ., Cookeville, TN (United States); Larsen, E.; Clark, D. [Lockheed Martin Idaho Technologies Co., Idaho Falls, ID (United States); King, P. [US Dept. of Energy Albany Research Center, Albany, OR (United States)

    1998-10-01

    In this paper we present some final results from a research project focused on introducing automatic control to the operation of cupola iron furnaces. The main aim of this research is to improve the operational efficiency and performance of the cupola furnace, an important foundry process used to melt iron. Previous papers have described the development of appropriate control system architectures for the cupola. These results are summarized. Then we describe the experimental results obtained with the U.S. Department of Energy Albany Research Center`s research cupola. First, experimental data is used to calibrate the model, which is taken as a first-order multivariable system with time delay. Then relative gain analysis is used to select loop pairings to be used in a multi-loop controller. The resulting controller pairs meltrate with blast volume, iron temperature with oxygen addition, and carbon composition with percent coke. Special (nonlinear) filters are used to compute meltrate from actual scale readings of the amount of iron produced and to smooth the temperature measurement. The temperature and meltrate loops use single-loop PI control. The composition loop uses a Smith predictor to discount the deadtime associated with mass transport through the furnace. Experimental results validate the conceptual controller design and provide proof-of-concept of the idea of controlling a foundry cupola. Future research directions are discussed, including the concept of an integrated, intelligent industrial process controller, or I{sup 3}PC.

  1. An experimental study of UWB device-free person detection and ranging

    NARCIS (Netherlands)

    Kilic, Y.; Wymeersch, Henk; Meijerink, Arjan; Bentum, Marinus Jan; Scanlon, W.G.

    2013-01-01

    Passive person detection and localization is an emerging area in UWB localization systems, whereby people are not required to carry any UWB ranging device. Based on experimental data, we propose a novel method to detect static persons in the absence of template waveforms, and to compute distances to

  2. Investigation of energy dissipation in meat with an experimental ultrasonic device

    International Nuclear Information System (INIS)

    Stasiak, D.M.; Dolatowski, Z.

    2000-01-01

    The phenomena concomitant with acoustic energy dissipation in meat were studied. An experimental ultrasonic device (25-37 kHz, 2 W/square cm) was applied. Measurements of meat temperature in ultrasonic field showed the temperature rise significant for technological reasons. In this respect the changes in water absorption ability and acidity of meat were also examined

  3. Physics-based mathematical models for quantum devices via experimental system identification

    Energy Technology Data Exchange (ETDEWEB)

    Schirmer, S G; Oi, D K L; Devitt, S J [Department of Applied Maths and Theoretical Physics, University of Cambridge, Wilberforce Rd, Cambridge, CB3 0WA (United Kingdom); SUPA, Department of Physics, University of Strathclyde, Glasgow G4 0NG (United Kingdom); National Institute of Informatics, 2-1-2 Hitotsubashi, Chiyoda-ku, Tokyo 101-8430 (Japan)], E-mail: sgs29@cam.ac.uk

    2008-03-15

    We consider the task of intrinsic control system identification for quantum devices. The problem of experimental determination of subspace confinement is considered, and simple general strategies for full Hamiltonian identification and decoherence characterization of a controlled two-level system are presented.

  4. Single cells as experimentation units in lab-on-a-chip devices

    NARCIS (Netherlands)

    le Gac, Severine; van den Berg, Albert

    'Lab-on-a-chip' technology (LOC) has now reached a mature state and is employed commonly in research in the life sciences. LOC devices make novel experimentation possible while providing a sophisticated environment for cellular investigation. As a next step, we introduce here the concept of a

  5. A new device-independent dimension witness and its experimental implementation

    Science.gov (United States)

    Cai, Yu; Bancal, Jean-Daniel; Romero, Jacquiline; Scarani, Valerio

    2016-07-01

    A dimension witness is a criterion that sets a lower bound on the dimension needed to reproduce the observed data. Three types of dimension witnesses can be found in the literature: device-dependent ones, in which the bound is obtained assuming some knowledge on the state and the measurements; device-independent prepare-and-measure ones, that can be applied to any system including classical ones; and device-independent Bell-based ones, that certify the minimal dimension of some entangled systems. Here we consider the Collins-Gisin-Linden-Massar-Popescu Bell-type inequality for four outcomes. We show that a sufficiently high violation of this inequality witnesses d≥slant 4 and present a proof-of-principle experimental observation of such a violation. This presents a first experimental violation of the third type of dimension witness beyond qutrits.

  6. Left ventricular assist device as destination therapy: application of the payment-by-results approach for the device reimbursement.

    Science.gov (United States)

    Messori, Andrea; Trippoli, Sabrina; Bonacchi, Massimo; Sani, Guido

    2009-08-01

    Value-based methods are increasingly used to reimburse therapeutic innovation, and the payment-by-results approach has been proposed for handling interventions with limited therapeutic evidence. Because most left ventricular assist devices are supported by preliminary efficacy data, we examined the effectiveness data of the HeartMate (Thoratec Corp, Pleasanton, CA) device to explore the application of the payment-by-results approach to these devices and to develop a model for handling reimbursements. According to our model, after establishing the societal economic countervalue for each month of life saved, each patient treated with one such device is associated to the payment of this countervalue for every month of survival lived beyond the final date of estimated life expectancy without left ventricular assist devices. Our base-case analysis, which used the published data of 68 patients who received the HeartMate device, was run with a monthly countervalue of euro 5000, no adjustment for quality of life, and a baseline life expectancy of 150 days without left ventricular assist devices. Sensitivity analysis was aimed at testing the effect of quality of life adjustments and changes in life expectancy without device. In our base-case analysis, the mean total reimbursement per patient was euro 82,426 (range, euro 0 to euro 250,000; N = 68) generated as the sum of monthly payments. This average value was close to the current price of the HeartMate device (euro 75,000). Sensitivity testing showed that the base-case reimbursement of euro 82,426 was little influenced by variations in life expectancy, whereas variations in utility had a more pronounced impact. Our report delineates an innovative procedure for appropriately allocating economic resources in this area of invasive cardiology.

  7. Thermodynamic properties of indan: Experimental and computational results

    International Nuclear Information System (INIS)

    Chirico, Robert D.; Steele, William V.; Kazakov, Andrei F.

    2016-01-01

    Highlights: • Heat capacities were measured for the temperature range (5 to 445) K. • Vapor pressures were measured for the temperature range (338 to 495) K. • Densities at saturation pressure were measured from T = (323 to 523) K. • Computed and experimentally derived properties for ideal gas entropies are in excellent accord. • Thermodynamic consistency analysis revealed anomalous literature data. - Abstract: Measurements leading to the calculation of thermodynamic properties in the ideal-gas state for indan (Chemical Abstracts registry number [496-11-7], 2,3-dihydro-1H-indene) are reported. Experimental methods were adiabatic heat-capacity calorimetry, differential scanning calorimetry, comparative ebulliometry, and vibrating-tube densitometry. Molar thermodynamic functions (enthalpies, entropies, and Gibbs energies) for the condensed and ideal-gas states were derived from the experimental studies at selected temperatures. Statistical calculations were performed based on molecular geometry optimization and vibrational frequencies calculated at the B3LYP/6-31+G(d, p) level of theory. Computed ideal-gas properties derived with the rigid-rotor harmonic-oscillator approximation are shown to be in excellent accord with ideal-gas entropies derived from thermophysical property measurements of this research, as well as with experimental heat capacities for the ideal-gas state reported in the literature. Literature spectroscopic studies and ab initio calculations report a range of values for the barrier to ring puckering. Results of the present work are consistent with a large barrier that allows use of the rigid-rotor harmonic-oscillator approximation for ideal-gas entropy and heat-capacity calculations, even with the stringent uncertainty requirements imposed by the calorimetric and physical property measurements reported here. All experimental results are compared with property values reported in the literature.

  8. Design, Manufacturing and Experimental Validation of Optical Fiber Sensors Based Devices for Structural Health Monitoring

    Directory of Open Access Journals (Sweden)

    Angela CORICCIATI

    2016-06-01

    Full Text Available The use of optical fiber sensors is a promising and rising technique used for Structural Health Monitoring (SHM, because permit to monitor continuously the strain and the temperature of the structure where they are applied. In the present paper three different types of smart devices, that are composite materials with an optical fiber sensor embedded inside them during the manufacturing process, are described: Smart Patch, Smart Rebar and Smart Textile, which are respectively a plate for local exterior intervention, a rod for shear and flexural interior reinforcement and a textile for an external whole application. In addition to the monitoring aim, the possible additional function of these devices could be the reinforcement of the structures where they are applied. In the present work, after technology manufacturing description, the experimental laboratory characterization of each device is discussed. At last, smart devices application on medium scale masonry walls and their validation by mechanical tests is described.

  9. Experimental Version of a cryopanel for pumping-out in ectors of thermonuclear devices

    International Nuclear Information System (INIS)

    Volkov, V.A.; Koryagin, N.I.; Kurakin, A.K.; Naumov, V.K.; Pustovojt, Yu.M.; Rabin, A.A.; Svishchev, V.S.; Sigalov, Yu.M.; Chukhin, I.A.

    1982-01-01

    The technology of producing rolled-welded cryopannels of cryocondensation pumps, build-in directly in the capacity of a fusion device (FD) is described. Results of measurements of exploitation characteristics of experimental cryopanel sample for pumping out of FD in ectors are given. A cryopanel consists of condensing surface and two protective screens. Cryopanel elements are formed during hot rolling of two sheets of the aluminium AD-1 alloy; the picture of the channel for a cooling agent is placed on one of them by antiwelding paste. After this, sheets are welded by hot rolling with total squeesing of 55-60%. The tests of the experimental sample performed have shown that at rather high pumping-out characteristics and small expense of cooling agents for the maintenance of operating regimes, cryopanel is simple and technological in production, small-sized, and requires lesser metal expense and production labour expense as compared with the known designs. The quality of welded joints is significantly reduced which increases the reliability of cryopumping-out system made of these panels

  10. Experimental Assessment of the Hydraulics of a Miniature Axial-Flow Left Ventricular Assist Device

    Science.gov (United States)

    Smith, P. Alex; Cohn, William; Metcalfe, Ralph

    2017-11-01

    A minimally invasive partial-support left ventricular assist device (LVAD) has been proposed with a flow path from the left atrium to the arterial system to reduce left ventricular stroke work. In LVAD design, peak and average efficiency must be balanced over the operating range to reduce blood trauma. Axial flow pumps have many geometric parameters. Until recently, testing all these parameters was impractical, but modern 3D printing technology enables multi-parameter studies. Following theoretical design, experimental hydraulic evaluation in steady state conditions examines pressure, flow, pressure-flow gradient, efficiency, torque, and axial force as output parameters. Preliminary results suggest that impeller blades and stator vanes with higher inlet angles than recommended by mean line theory (MLT) produce flatter gradients and broader efficiency curves, increasing compatibility with heart physiology. These blades also produce less axial force, which reduces bearing load. However, they require slightly higher torque, which is more demanding of the motor. MLT is a low order, empirical model developed on large pumps. It does not account for the significant viscous losses in small pumps like LVADs. This emphasizes the importance of experimental testing for hydraulic design. Roderick D MacDonald Research Fund.

  11. Recent experimental results on level densities for compound reaction calculations

    International Nuclear Information System (INIS)

    Voinov, A.V.

    2012-01-01

    There is a problem related to the choice of the level density input for Hauser-Feshbach model calculations. Modern computer codes have several options to choose from but it is not clear which of them has to be used in some particular cases. Availability of many options helps to describe existing experimental data but it creates problems when it comes to predictions. Traditionally, different level density systematics are based on experimental data from neutron resonance spacing which are available for a limited spin interval and one parity only. On the other hand reaction cross section calculations use the total level density. This can create large uncertainties when converting the neutron resonance spacing to the total level density that results in sizable uncertainties in cross section calculations. It is clear now that total level densities need to be studied experimentally in a systematic manner. Such information can be obtained only from spectra of compound nuclear reactions. The question is does level densities obtained from compound nuclear reactions keep the same regularities as level densities obtained from neutron resonances- Are they consistent- We measured level densities of 59-64 Ni isotopes from proton evaporation spectra of 6,7 Li induced reactions. Experimental data are presented. Conclusions of how level density depends on the neutron number and on the degree of proximity to the closed shell ( 56 Ni) are drawn. The level density parameters have been compared with parameters obtained from the analysis of neutron resonances and from model predictions

  12. Divertors for helical devices: Concepts, plans, results and problems

    International Nuclear Information System (INIS)

    Koenig, R.; Grigull, P.; McCormick, K.

    2003-01-01

    With LHD and W7-X stellarator development is now taking a large leap forward on the path to a steady-state fusion reactor. Important issues that need to be settled in these machines are particle flux and heat control, and the impact of divertors on plasma performance in future continuously burning fusion plasmas. The divertor concepts that will initially be explored in these large stellarators were carefully prepared in smaller scale devices like Heliotron E, CHS and W7-AS. While advanced divertor scenarios relevant for W7-X were already studied in W7-AS, other smaller scale experiments like Heliotron-J, CHS and NCSX will be used for the further development of divertor concepts. The two divertor configurations that are presently being investigated, are the helical and the island divertor, as well as the local island divertor (LID), which was successfully demonstrated on CHS and just went into operation on LHD. Presently, on its route to a fully closed helical divertor, LHD operates in an open helical divertor configuration. W7-X will be equipped right from the start with an actively cooled discrete island divertor which will allow quasi continuous operation. The divertor design is very similar to the one explored on W7-AS. For sufficiently large island sizes and not too long field line connection lengths, this divertor gives access to a partially detached quasi steady-state operating scenario in a newly found high density H-mode operating regime, which benefits from high energy and extremely low impurity confinement times, with edge radiation levels of up to 90 % and sufficient neutral compression in the subdivertor region (> 10) for active pumping. The basic physics of the different divertor concepts and associated implementation problems, like asymmetries due to drifts, accessibility of essential operating scenarios and toroidal asymmetries due to symmetry breaking error fields, etc. will be discussed. (orig.)

  13. International registry results for an interstitial laser BPH treatment device

    Science.gov (United States)

    Conn, Richard L.; Muschter, Rolf; Adams, Curtis S.; Esch, Victor C.

    1996-05-01

    Benign prostatic hyperplasia (BPH) can significantly impair quality of life in older men. Most men over 60 experience some symptoms due to BPH and it is thought that essentially all men would eventually be affected by it if they lived long enough. At present, transurethral resection of the prostate (TURP), a surgical treatment for BPH, is one of the more common procedures performed in the developed world, particularly in the United States. A number of other treatments are also often used, including open prostatectomy, side-firing lasers, and drug therapy. With the population in the developed world rapidly aging, BPH is expected to affect an even larger group of men in the future. Current methods of therapy carry significant disadvantages. Open prostatectomy carries a fairly high risk of impotence and incontinence, as well as sometimes significant risk of death depending on the patient's age and medical conditions. TURP also carries similar risks, albeit reduced, including the risk of substantial blood loss and a small but meaningful risk of death. Side-firing lasers are thought to have a reduced risk of death compared to TURP due to significantly reduced bleeding; however, patients often experience an extended period of pain during voiding due to prolonged tissue sloughing. Drug treatment, although useful for some patients, does not strongly improve symptoms in the majority of patients. Even with the current range of treatments, many patients with symptomatic BPH elect to avoid any current treatment due to risks and side effects. As a possible solution to this problem, previous writers have suggested the possibility of treating BPH through interstitial thermotherapy. In this treatment, prostatic tissue is heated from within the prostate to the point of irreversible necrosis. Healing processes then reduce the volume of the affected tissue, even in the absence of sloughing. This study covers initial human use of such a device, using an 810 nm wavelength diode laser

  14. Results of experimental electromagnetic studies of the Crimean region

    OpenAIRE

    Burakhovich, T. K.; Kushnir, A. M.; Nikolaev, I. Yu.; Sheremet, E. M.; Shirkov, B. I.

    2017-01-01

    Spatial-temporal pattern of distribution of geomagnetic variations and the electric field on the Earth’s surface was obtained as a result of the modern experimental observations conducted in 2007—2013 along 9 profiles (48 points) by the methods of magnetotelluric sounding (MTS) and magnetovariation profiling (MVP). These profiles cross various geological structures of the Crimean region. It is possible to estimate the value of the electrical conductivity and vertical and horizontal geoelectri...

  15. Primarily Experimental Results for a W Wire Array Z Pinch

    International Nuclear Information System (INIS)

    Kuai Bin; Aici, Qiu; Wang Liangping; Zeng Zhengzhong; Wang Wensheng; Cong Peitian; Gai Tongyang; Wei Fuli; Guo Ning; Zhang Zhong

    2006-01-01

    Primarily experimental results are given for a W wire array Z pinch imploded with up to 2 MA in 100 ns on a Qiangguang-I pulsed power generator. The configuration and parameters of the generator, the W wire array load assembly and the diagnostic system for the experiment are described. The total X-ray energy has been obtained with a averaged power of X-ray radiation of 1.28 TW

  16. Heavy ions testing experimental results on programmable integrated circuits

    International Nuclear Information System (INIS)

    Velazco, R.; Provost-Grellier, A.

    1988-01-01

    The natural radiation environment in space has been shown to produce anomalies in satellite-borne microelectronics. It becomes then mandatory to define qualification strategies allowing to choose the less vulnerable circuits. In this paper, is presented a strategy devoted to one of the most critical effects, the soft errors (so called upset). The method addresses programmable integrated circuits i.e. circuits able to execute an instruction or command set. Experimental results on representative circuits will illustrate the approach. 11 refs [fr

  17. Animal experimental research of the endothelialization of home-made atrial septal defect occluder device

    International Nuclear Information System (INIS)

    Chen Mingwu; Zhou Aiqing; Li Feng; Gao Wei; Yu Zhiqing; Tang Ning; Zhang Lan

    2003-01-01

    Objective: To evaluate the endothelialization of Chinese nitinol atrial septal defect occluder device. Methods: Atrial septal defect with controllable size was created by the Brockenborough needle and Rashkind balloon atrial septostomy, the occluder devices were implanted in six piglets (mean weight 7.5 kg). Two pigs were killed each time after 1 month, 3 months and 6 months after the device implantation and then the explanted devices were examined by scanning electron microscope (SEM). Results: The devices were found covering with collagen fibrosis together with diffuse endothelial cells spreading over the primer 1 month after implantation. The implants were covered mostly by neointima 3 months after implantation and completely covered by confluent endothelial cells 6 months after the implantation. Endothelial cells were not found on the smooth marker band at 3 months, however, did exist by 6 months. Conclusions: Home-made atrial septal defect occluder devices were mostly endothelialised 3 months after the implantation and did completely at 6 months

  18. Design project of the experimental device for studying the uranium Creep in the reactor; Predprojekat eksperimentalnog uredjaja za ispitivanje CREEP-a urana u reaktoru

    Energy Technology Data Exchange (ETDEWEB)

    Pavicevic, M [Institute of Nuclear Sciences Boris Kidric, Odeljenje za reaktorsku eksperimentalnu tehniku, Vinca, Beograd (Serbia and Montenegro)

    1963-12-15

    The objective of this task was constructing a device for creep testing of uranium, i.e permanent deformation of the irradiated fuel. Deformation results from the influence of thermal neutron flux, temperature, time of irradiation, mechanical stress. This describes two possible technical solutions experimental device for creep testing in the vertical experimental channel and in the horizontal experimental channel of the RA reactor. In addition to the design details, the report covers calculations of heat generation, antireactivity, activation of the materials of the constructed experimental loop, mechanical calculations as well as description of measurements and regulation of the uranium sample temperature.

  19. Experimental results pertaining to the performance of thermal igniters

    International Nuclear Information System (INIS)

    Carmel, M.K.

    1989-10-01

    This report summarizes the results of various experimental programs regarding the performance of thermal igniters for the deliberate ignition of hydrogen in light water reactors. Experiments involving both premixed combustion and combustion with continuous hydrogen injection are reviewed. Combustion characteristics examined include flammability limits of hydrogen:air and hydrogen:air:steam mixtures, combustion pressure rises, combustion completeness, flame speeds, and heat transfer aspects. Comparisons of igniter type and igniter reliability under simulated reactor accident conditions are included. The results of the research programs provide a broad data base covering nearly all aspects of hydrogen combustion related to the performance of deliberate ignition systems

  20. OIL DECONTAMINATION OF BOTTOM SEDIMENTS EXPERIMENTAL WORK RESULTS

    Directory of Open Access Journals (Sweden)

    Lushnikov Sergey V.

    2006-08-01

    Full Text Available This article presents the results of experimental work during 2004-2005 on oil decontamination of bottom sediments of Lake Schuchye, situated in the Komi Republic (Northern Russia. The cause of thecontamination were huge oil spills occurred after a series of accidental ruptures on the Harjaga-Usinsk and Vozej-Usinsk oil-pipe lines in 1994. Flotation technology was used for the cleaning of bottom sediments.157 tons of crude oil were removed during the course of 2-year experimental work from an area of 4,1 ha.The content of aliphatic and alicyclic oil hydrocarbons was reduced from 53,3 g/kg to 2,2 g/kg, on average.Hydrobiological investigations revealed that bottom sediments started to be inhabited by benthos organisms, dominantly Oligochaeta. Besides Oligochaeta, Chironomidae maggots and Bivalvia were detected. Theappearance of Macrozoobenthos organisms can serve as a bioindicator of water quality.

  1. A numerical analysis and experimental demonstration of a low degradation conductive bridge resistive memory device

    Science.gov (United States)

    Berco, Dan; Chand, Umesh; Fariborzi, Hossein

    2017-10-01

    This study investigates a low degradation metal-ion conductive bridge RAM (CBRAM) structure. The structure is based on placing a diffusion blocking layer (DBL) between the device's top electrode (TE) and the resistive switching layer (RSL), unlike conventional CBRAMs, where the TE serves as a supply reservoir for metallic species diffusing into the RSL to form a conductive filament (CF) and is kept in direct contact with the RSL. The properties of a conventional CBRAM structure (Cu/HfO2/TiN), having a Cu TE, 10 nm HfO2 RSL, and a TiN bottom electrode, are compared with a 2 nm TaN DBL incorporating structure (Cu/TaN/HfO2/TiN) for 103 programming and erase simulation cycles. The low and high resistive state values for each cycle are calculated and the analysis reveals that adding the DBL yields lower degradation. In addition, the 2D distribution plots of oxygen vacancies, O ions, and Cu species within the RSL indicate that oxidation occurring in the DBL-RSL interface results in the formation of a sub-stoichiometric tantalum oxynitride with higher blocking capabilities that suppresses further Cu insertion beyond an initial CF formation phase, as well as CF lateral widening during cycling. The higher endurance of the structure with DBL may thus be attributed to the relatively low amount of Cu migrating into the RSL during the initial CF formation. Furthermore, this isomorphic CF displays similar cycling behavior to neural ionic channels. The results of numerical analysis show a good match to experimental measurements of similar device structures as well.

  2. A numerical analysis and experimental demonstration of a low degradation conductive bridge resistive memory device

    KAUST Repository

    Berco, Dan; Chand, Umesh; Fariborzi, Hossein

    2017-01-01

    This study investigates a low degradation metal-ion conductive bridge RAM (CBRAM) structure. The structure is based on placing a diffusion blocking layer (DBL) between the device's top electrode (TE) and the resistive switching layer (RSL), unlike conventional CBRAMs, where the TE serves as a supply reservoir for metallic species diffusing into the RSL to form a conductive filament (CF) and is kept in direct contact with the RSL. The properties of a conventional CBRAM structure (Cu/HfO2/TiN), having a Cu TE, 10 nm HfO2 RSL, and a TiN bottom electrode, are compared with a 2 nm TaN DBL incorporating structure (Cu/TaN/HfO2/TiN) for 103 programming and erase simulation cycles. The low and high resistive state values for each cycle are calculated and the analysis reveals that adding the DBL yields lower degradation. In addition, the 2D distribution plots of oxygen vacancies, O ions, and Cu species within the RSL indicate that oxidation occurring in the DBL-RSL interface results in the formation of a sub-stoichiometric tantalum oxynitride with higher blocking capabilities that suppresses further Cu insertion beyond an initial CF formation phase, as well as CF lateral widening during cycling. The higher endurance of the structure with DBL may thus be attributed to the relatively low amount of Cu migrating into the RSL during the initial CF formation. Furthermore, this isomorphic CF displays similar cycling behavior to neural ionic channels. The results of numerical analysis show a good match to experimental measurements of similar device structures as well

  3. Lessons from wet gas flow metering systems using differential measurements devices: Testing and flow modelling results

    Energy Technology Data Exchange (ETDEWEB)

    Cazin, J.; Couput, J.P.; Dudezert, C. et al

    2005-07-01

    A significant number of wet gas meters used for high GVF and very high GVF are based on differential pressure measurements. Recent high pressure tests performed on a variety of different DP devices on different flow loops are presented. Application of existing correlations is discussed for several DP devices including Venturi meters. For Venturi meters, deviations vary from 9% when using the Murdock correlation to less than 3 % with physical based models. The use of DP system in a large domain of conditions (Water Liquid Ratio) especially for liquid estimation will require information on the WLR This obviously raises the question of the gas and liquid flow metering accuracy in wet gas meters and highlight needs to understand AP systems behaviour in wet gas flows (annular / mist / annular mist). As an example, experimental results obtained on the influence of liquid film characteristics on a Venturi meter are presented. Visualizations of the film upstream and inside the Venturi meter are shown. They are completed by film characterization. The AP measurements indicate that for a same Lockhart Martinelli parameter, the characteristics of the two phase flow have a major influence on the correlation coefficient. A 1D model is defined and the results are compared with the experiments. These results indicate that the flow regime influences the AP measurements and that a better modelling of the flow phenomena is needed even for allocation purposes. Based on that, lessons and way forward in wet gas metering systems improvement for allocation and well metering are discussed and proposed. (author) (tk)

  4. Shock wave effects in copper: Design of an experimental device for post recovery mechanical testing

    International Nuclear Information System (INIS)

    Buy, Francois; Llorca, Fabrice

    2002-01-01

    The mechanical behavior of metals may prove high changes with strain rate and pressure loading history. In order to investigate the effect of a shock on the ulterior mechanical behavior of high purity copper, we set up an experimental device inspired from G. T. Gray III's works. This device, based on the trapping of shock waves after a plane plate impact is validated by numerical simulations. The aim of these simulations is the evaluation of the heterogeneity of plastic deformation. Shock pressures up to 10 GPa have been investigated. The plastic strain levels subsequent to the shock are between 0.08 and 0.15 in the sample

  5. The IPIRG-1 pipe system fracture tests: Experimental results

    International Nuclear Information System (INIS)

    Scott, P.; Olson, R.J.; Wilkowski, G.M.

    1994-01-01

    As part of the First International Piping Integrity Research Group (IPIRG-1) program, six dynamic pipe system experiments were conducted. The objective of these experiments was to generate experimental data to assess analysis methodologies for characterizing the fracture behavior of circumferentially cracked pipe in a representative piping system subjected to combined inertial and displacement-controlled stresses. A unique experimental facility was designed and constructed. The pipe system evaluated was an expansion loop with over 30 m (100 feet) of 16-inch nominal diameter Schedule 100 pipe. The experimental facility was equipped with special hardware to ensure that system boundary conditions could be appropriately modeled. The test matrix involved one uncracked and five cracked dynamic pipe system experiments. The uncracked-pipe experiment was conducted to evaluate the piping system damping and natural frequency characteristics. The cracked-pipe experiments were conducted to evaluate the fracture behavior, piping system response, and fracture stability characteristics of five different materials. All cracked-pipe experiments were conducted at PWR conditions. Material characterization efforts provided the tensile and fracture toughness properties of the different pipe materials at various strain rates and temperatures. Key results from the six pipe system experiments and material characterization efforts are presented. Detailed analyses will be published in a companion paper

  6. Security Issues and Resulting Security Policies for Mobile Devices

    Science.gov (United States)

    2013-03-01

    session, he drafts one more email to his therapist complaining about stress prior to retiring for the night. The next day, when he wakes up and returns... telecommuters or a web server to make internal information available to employees are identified upfront in the requirements analysis. The results of

  7. Preliminary results of neutron production in Sahand plasma focus device

    International Nuclear Information System (INIS)

    Siahpoush, V.; Mohammadi, M.A.; Khorram, S.; Shabani, I.; Borhanian, J.; Ashrafi, S.; Naghshara, H.; Moslehi-Fard, M.; Sobhanian, S.

    2004-01-01

    We report in this paper the preliminary results of neutron generation during fusion reaction in deuterium in the Sahand Filipov type plasma focus, recently installed and put in operation at Tabriz University. The special calibration procedure for neutron detection system, using activation method is described

  8. Scoliosis correction with shape-memory metal: results of an experimental study

    OpenAIRE

    Wever, D.; Elstrodt, J.; Veldhuizen, A.; v Horn, J.

    2001-01-01

    The biocompatibility and functionality of a new scoliosis correction device, based on the properties of the shape-memory metal nickel-titanium alloy, were studied. With this device, the shape recovery forces of a shape-memory metal rod are used to achieve a gradual three-dimensional scoliosis correction. In the experimental study the action of the new device was inverted: the device was used to induce a scoliotic curve instead of correcting one. Surgical procedures were performed in six pigs....

  9. Security analysis on some experimental quantum key distribution systems with imperfect optical and electrical devices

    Science.gov (United States)

    Liang, Lin-Mei; Sun, Shi-Hai; Jiang, Mu-Sheng; Li, Chun-Yan

    2014-10-01

    In general, quantum key distribution (QKD) has been proved unconditionally secure for perfect devices due to quantum uncertainty principle, quantum noncloning theorem and quantum nondividing principle which means that a quantum cannot be divided further. However, the practical optical and electrical devices used in the system are imperfect, which can be exploited by the eavesdropper to partially or totally spy the secret key between the legitimate parties. In this article, we first briefly review the recent work on quantum hacking on some experimental QKD systems with respect to imperfect devices carried out internationally, then we will present our recent hacking works in details, including passive faraday mirror attack, partially random phase attack, wavelength-selected photon-number-splitting attack, frequency shift attack, and single-photon-detector attack. Those quantum attack reminds people to improve the security existed in practical QKD systems due to imperfect devices by simply adding countermeasure or adopting a totally different protocol such as measurement-device independent protocol to avoid quantum hacking on the imperfection of measurement devices [Lo, et al., Phys. Rev. Lett., 2012, 108: 130503].

  10. Comparison the Results of Numerical Simulation And Experimental Results for Amirkabir Plasma Focus Facility

    Science.gov (United States)

    Goudarzi, Shervin; Amrollahi, R.; Niknam Sharak, M.

    2014-06-01

    In this paper the results of the numerical simulation for Amirkabir Mather-type Plasma Focus Facility (16 kV, 36μF and 115 nH) in several experiments with Argon as working gas at different working conditions (different discharge voltages and gas pressures) have been presented and compared with the experimental results. Two different models have been used for simulation: five-phase model of Lee and lumped parameter model of Gonzalez. It is seen that the results (optimum pressures and current signals) of the Lee model at different working conditions show better agreement than lumped parameter model with experimental values.

  11. Comparison the results of numerical simulation and experimental results for Amirkabir plasma focus facility

    International Nuclear Information System (INIS)

    Goudarzi, Shervin; Amrollahi, R; Sharak, M Niknam

    2014-01-01

    In this paper the results of the numerical simulation for Amirkabir Mather-type Plasma Focus Facility (16 kV, 36μF and 115 nH) in several experiments with Argon as working gas at different working conditions (different discharge voltages and gas pressures) have been presented and compared with the experimental results. Two different models have been used for simulation: five-phase model of Lee and lumped parameter model of Gonzalez. It is seen that the results (optimum pressures and current signals) of the Lee model at different working conditions show better agreement than lumped parameter model with experimental values.

  12. Assessing incentive contracts for reducing residential electricity consumption: new experimental methods for new results

    International Nuclear Information System (INIS)

    Frachet, Laure

    2013-01-01

    Facing economic, political and environmental stakes, electricity providers are nowadays developing incentive tools, in order to reduce consumer's demand, particularly during peak demand periods. For residential customers, these tools can be tariffs (dynamic pricing of time-of-use tariffs), or informative devices or services (feedbacks on historical or real-time consumption, given on various media). They might go along with automation systems that can help cutting of some electric devices when needed. In order to evaluate the capacity of these settings among their customers, electricity utilities are developing quite a few studies, which are mainly field experiment often called pilots. During these pilots, demand response tools are implemented on a population sample. These long and expensive studies lid to quantitative and qualitative analysis. We have compiled about 40 of them and extract from this survey some generalizable teachings. We have shown what these results were and highlighted pilot programs' methodological limits. In order to propose a substitute to these heavy experimentations, we assessed the capacity or experimental economics. This relatively new discipline's objective is to evaluation the efficiency of institutions, like markets, but also to study what animate economic agents' behaviour, e.g. preferences, beliefs, cognitive biases, willingness to pay... We were also able to elaborate an experimental protocol dedicated to the evaluation of some demand response contracts' acceptability. The results collected during 14 experimental sessions gave us some innovative clues and insight on these contracts acceptability. But, beyond these results, we have demonstrated that even if experimental economics can't obviously be a substitute for field experiments, it can represent an interesting exploratory methodology. To sum up the experimental economics can take part of residential customers' behaviour understanding, performing

  13. ANOVA parameters influence in LCF experimental data and simulation results

    Directory of Open Access Journals (Sweden)

    Vercelli A.

    2010-06-01

    Full Text Available The virtual design of components undergoing thermo mechanical fatigue (TMF and plastic strains is usually run in many phases. The numerical finite element method gives a useful instrument which becomes increasingly effective as the geometrical and numerical modelling gets more accurate. The constitutive model definition plays an important role in the effectiveness of the numerical simulation [1, 2] as, for example, shown in Figure 1. In this picture it is shown how a good cyclic plasticity constitutive model can simulate a cyclic load experiment. The component life estimation is the subsequent phase and it needs complex damage and life estimation models [3-5] which take into account of several parameters and phenomena contributing to damage and life duration. The calibration of these constitutive and damage models requires an accurate testing activity. In the present paper the main topic of the research activity is to investigate whether the parameters, which result to be influent in the experimental activity, influence the numerical simulations, thus defining the effectiveness of the models in taking into account of all the phenomena actually influencing the life of the component. To obtain this aim a procedure to tune the parameters needed to estimate the life of mechanical components undergoing TMF and plastic strains is presented for commercial steel. This procedure aims to be easy and to allow calibrating both material constitutive model (for the numerical structural simulation and the damage and life model (for life assessment. The procedure has been applied to specimens. The experimental activity has been developed on three sets of tests run at several temperatures: static tests, high cycle fatigue (HCF tests, low cycle fatigue (LCF tests. The numerical structural FEM simulations have been run on a commercial non linear solver, ABAQUS®6.8. The simulations replied the experimental tests. The stress, strain, thermal results from the thermo

  14. An analytical model for backscattered luminance in fog: comparisons with Monte Carlo computations and experimental results

    International Nuclear Information System (INIS)

    Taillade, Frédéric; Dumont, Eric; Belin, Etienne

    2008-01-01

    We propose an analytical model for backscattered luminance in fog and derive an expression for the visibility signal-to-noise ratio as a function of meteorological visibility distance. The model uses single scattering processes. It is based on the Mie theory and the geometry of the optical device (emitter and receiver). In particular, we present an overlap function and take the phase function of fog into account. The results of the backscattered luminance obtained with our analytical model are compared to simulations made using the Monte Carlo method based on multiple scattering processes. An excellent agreement is found in that the discrepancy between the results is smaller than the Monte Carlo standard uncertainties. If we take no account of the geometry of the optical device, the results of the model-estimated backscattered luminance differ from the simulations by a factor 20. We also conclude that the signal-to-noise ratio computed with the Monte Carlo method and our analytical model is in good agreement with experimental results since the mean difference between the calculations and experimental measurements is smaller than the experimental uncertainty

  15. Development and experimental verification of a finite element method for accurate analysis of a surface acoustic wave device

    Science.gov (United States)

    Mohibul Kabir, K. M.; Matthews, Glenn I.; Sabri, Ylias M.; Russo, Salvy P.; Ippolito, Samuel J.; Bhargava, Suresh K.

    2016-03-01

    Accurate analysis of surface acoustic wave (SAW) devices is highly important due to their use in ever-growing applications in electronics, telecommunication and chemical sensing. In this study, a novel approach for analyzing the SAW devices was developed based on a series of two-dimensional finite element method (FEM) simulations, which has been experimentally verified. It was found that the frequency response of the two SAW device structures, each having slightly different bandwidth and center lobe characteristics, can be successfully obtained utilizing the current density of the electrodes via FEM simulations. The two SAW structures were based on XY Lithium Niobate (LiNbO3) substrates and had two and four electrode finger pairs in both of their interdigital transducers, respectively. Later, SAW devices were fabricated in accordance with the simulated models and their measured frequency responses were found to correlate well with the obtained simulations results. The results indicated that better match between calculated and measured frequency response can be obtained when one of the input electrode finger pairs was set at zero volts and all the current density components were taken into account when calculating the frequency response of the simulated SAW device structures.

  16. Development of electrical insulation and conduction coating for fusion experimental devices

    Energy Technology Data Exchange (ETDEWEB)

    Onozuka, M. [Mitsubishi Heavy Industries Ltd., Yokohama (Japan); Tsujimura, S. [Mitsubishi Heavy Industries Ltd., Yokohama (Japan); Toyoda, M. [Mitsubishi Heavy Industries Ltd., Yokohama (Japan); Inoue, M. [Mitsubishi Heavy Industries Ltd., Yokohama (Japan); Abe, T. [Japan Atomic Energy Research Inst., Naka (Japan); Murakami, Y. [Japan Atomic Energy Research Inst., Naka (Japan)

    1995-12-31

    Development of electrical insulation and conduction methods that can be applied for large components have been investigated for future large fusion experimental devices. A thermal spraying method is employed to coat the insulation or conduction materials on the structural components. Al{sub 2}O{sub 3} has been selected as an insulation material, while Cr{sub 3}C{sub 2}-NiCr and WC-NiCr have been chosen as conduction materials. These materials were coated on stainless steel base plates to examine the basic characteristics of the coated layers, such as their adhesive strength to the base plate and electrical resistance. It was found that they have sufficient electrical insulation and conduction properties, respectively. In addition, the sliding tests of the coated layers showed sufficient frictional properties. The applicability of the spraying method was examined on a 100mm x 1000mm surface and found to be applicable for large surfaces in fusion experimental devices. (orig.).

  17. Development of electrical insulation and conduction coating for fusion experimental devices

    International Nuclear Information System (INIS)

    Onozuka, M.; Tsujimura, S.; Toyoda, M.; Inoue, M.; Abe, T.; Murakami, Y.

    1995-01-01

    Development of electrical insulation and conduction methods that can be applied for large components have been investigated for future large fusion experimental devices. A thermal spraying method is employed to coat the insulation or conduction materials on the structural components. Al 2 O 3 has been selected as an insulation material, while Cr 3 C 2 -NiCr and WC-NiCr have been chosen as conduction materials. These materials were coated on stainless steel base plates to examine the basic characteristics of the coated layers, such as their adhesive strength to the base plate and electrical resistance. It was found that they have sufficient electrical insulation and conduction properties, respectively. In addition, the sliding tests of the coated layers showed sufficient frictional properties. The applicability of the spraying method was examined on a 100mm x 1000mm surface and found to be applicable for large surfaces in fusion experimental devices. (orig.)

  18. Development of a New Intravascular Low-Profile Device for Exclusion of Aortic Aneurysm: An Experimental Pilot Study

    International Nuclear Information System (INIS)

    Strecker, Ernst-Peter; Haberstroh, Joerg; Boos, Irene; Metz, Stephan; Langer, Mathias; Moliner, Manuel Maynar

    2004-01-01

    Purpose: To present a new intravascular device for the treatment of aorto-iliac aneurysms. Methods: This new device was tested in five dogs with abdominal aortic aneurysm created experimentally by overdilation of a balloon-expandable stent with a 16 or 18 mm wide PTA balloon catheter. The design of the device is based on a self-expanding aortic stent which consists of two stretchable circular frames filled with a textile Dacron mesh membrane that is suspended horizontally into the infrarenal abdominal aorta proximally to the aneurysm. The frames are part of a preshaped double helical structure that is introduced longitudinally through a catheter in a parallel fashion and forming the desired shape at the vessel site to be occluded. Two iliac stent-grafts are introduced in a low-profile status through the membrane sealing the aneurysm sac and holding the stent-grafts in place. After stent-graft expansion, a new bifurcation located more proximally than the natural one is created. The follow-up of the dogs was performed clinically and angiographically, and specimens were evaluated histomorphologically. Results: The membrane device can be introduced through a 9 Fr vascular sheath. Technical success was achieved in four of five dogs. Nine of ten stent-grafts could be fixed securely within the membrane, thus preventing dislocation. Aneurysms were excluded immediately, and blood flow to the external iliac arteries was restored by the stent-grafts. At 6-9 months follow-up of technically successful implanted devices, there were no endoleaks, no migration, no stenoses at contact sites between the implant material and vascular wall, and no stenosis or occlusion of the stent-grafts. At microscopic evaluation, the interspace between the membranes was filled with thrombotic material, thus ensuring exclusion of the aneurysm. Conclusion: This new device was found to be flexible, low profile and useful in excluding abdominal aortic aneurysm in the experimental setting

  19. Preliminary experimental results from a linear reciprocating magnetic refrigerator prototype

    International Nuclear Information System (INIS)

    Tagliafico, Luca Antonio; Scarpa, Federico; Valsuani, Federico; Tagliafico, Giulio

    2013-01-01

    A linear reciprocating magnetic refrigerator prototype was designed and built with the aid of an industrial partner. The refrigerator is based on the Active Magnetic Regenerative cycle, and exploits two regenerators working in parallel. The active material is Gadolinium in plates, 0.8 mm thick, for a total mass of 0.36 kg. The device is described and results about magnetic field and temperature span measurements are presented. The designed permanent magnet structure, based on an improved cross-type arrangement, generates a maximum magnetic field intensity of 1.55 T in air, over a gap of (13 × 50 × 100) mm 3 . The maximum temperature span achieved is 5.0 K, in a free run condition. -- Highlights: ► We give preliminary results from a linear reciprocating magnetic refrigerator prototype. ► The design is intended to process visualization and investigation. ► The prototype behavior gives us various suggestions to improve its general performance

  20. Comparison of ATHENA/RELAP results against ice experimental data

    CERN Document Server

    Moore-Richard, L

    2002-01-01

    In order to demonstrate the adequacy of the International Thermonuclear Experimental Reactor design from a safety stand point as well as investigating the behavior of two-phase flow phenomena during an ingress of coolant event, an integrated ICE test facility was constructed in Japan. The data generated from the ICE facility offers a valuable means to validate computer codes such as ATHENA /RELAP5, which is one of the codes used at the Idaho National Engineering And Environmental Laboratory (INEEL) to evaluate the safety of various fusion reactor concepts. In this paper we compared numerical results generated by the ATHENA code with corresponding test data from the ICE facility. Overall we found good agreement between the test data and the predicted results.

  1. Experimental device for obtaining calibration factor for the total count technique

    International Nuclear Information System (INIS)

    Gonçalves, Eduardo R.; Braz, Delson; Brandão, Luís Eduardo B.

    2017-01-01

    Nuclear technologies have widely used on industry plants in order to help to solve troubles processes/design or just obtain information of them. The Total Count technique for flow measurement has as main advantages: being an absolute technique, because it is independent of additional devices readings unless the directly used for recording the radioactive cloud, requiring only a single detector to provide the final result; the independence of the internal volume of the transport duct, can be applied in the presence or absence of obstructions; no restriction as to the nature of the product or material to be conveyed; it is a noninvasive technique which allows real-time diagnostics. To use Total Count Technique, knowledge of a geometric calibration factor is required. Called Factor F, it is obtained in the laboratory using an experimental apparatus to faithfully reproduce the geometry of the detection system and the pipeline that being analyzed and using the same radiotracer, therefore, its value is constant for each specific measuring system under survey. This experimental apparatus for obtaining the factor F consisting by a pipe of 2 ″PVC, which simulates a transmission line, where they were deposited 500 ml oil and the use of a specific pipette for use viscous fluids were added sequentially aliquots (50.00 ± 0.01) μl radiotracer (radionuclide photopeak energy of 198 Au 411.8 keV) and analyzing data obtained by three distinct detection systems composed of detectors NaI scintillators 1″ x 1 ″ and a data acquisition system. (author)

  2. Experimental device for obtaining calibration factor for the total count technique

    Energy Technology Data Exchange (ETDEWEB)

    Gonçalves, Eduardo R.; Braz, Delson [Coordenacao de Pos-Graduacao e Pesquisa de Engenharia (PEN/COPPE/UFRJ), Rio de Janeiro, RJ (Brazil). Programa de Engenharia Nuclear; Brandão, Luís Eduardo B. [Instituto de Engenharia Nuclear (IEN/CNEN-RJ), Rio de Janeiro, RJ (Brazil). Divisao de Reatores

    2017-07-01

    Nuclear technologies have widely used on industry plants in order to help to solve troubles processes/design or just obtain information of them. The Total Count technique for flow measurement has as main advantages: being an absolute technique, because it is independent of additional devices readings unless the directly used for recording the radioactive cloud, requiring only a single detector to provide the final result; the independence of the internal volume of the transport duct, can be applied in the presence or absence of obstructions; no restriction as to the nature of the product or material to be conveyed; it is a noninvasive technique which allows real-time diagnostics. To use Total Count Technique, knowledge of a geometric calibration factor is required. Called Factor F, it is obtained in the laboratory using an experimental apparatus to faithfully reproduce the geometry of the detection system and the pipeline that being analyzed and using the same radiotracer, therefore, its value is constant for each specific measuring system under survey. This experimental apparatus for obtaining the factor F consisting by a pipe of 2 ″PVC, which simulates a transmission line, where they were deposited 500 ml oil and the use of a specific pipette for use viscous fluids were added sequentially aliquots (50.00 ± 0.01) μl radiotracer (radionuclide photopeak energy of 198 Au 411.8 keV) and analyzing data obtained by three distinct detection systems composed of detectors NaI scintillators 1″ x 1 ″ and a data acquisition system. (author)

  3. Study of an automatized experimental device for the irradiation of a radioactive target

    International Nuclear Information System (INIS)

    Claverie, G.

    1996-01-01

    In order to solve the enigma of solar neutrinos, a team of physicians of the nuclear research center of Bordeaux-Gradignan and of the center of nuclear spectroscopy and mass spectroscopy of Orsay (France) decided to measure again the cross section of the beryllium-proton nuclear reaction at the lowest possible energies. This measurement requires the design of an automatized experimental device to irradiate in a specific way a beryllium target with an accelerated proton beam. The aim of this work is the study of such a device for an energy range of 800 to 300 KeV. This device comprises a particle multi-detector and a shutter for the irradiation of the target and the counting of the reaction products according to a programmable time sequence. The advantage of this setup is to allow an important bombardment of the target and to ensure its cooling. This device is automatically controlled thanks to a micro-controller, actuators (step motors and electrostatic deflector). It includes some beam diagnosis elements controlled by step motors and a target temperature monitoring system controlling a safety valve. The management of the experiment cell vacuum has led to the design of a vacuum monitor allowing the precise follow up of the vacuum and the control of the safety valves of the device. The nuclear instrumentation necessary to be implemented for this measurement is also presented. (J.S.)

  4. Experimental results of the ATF in-line injection system

    International Nuclear Information System (INIS)

    Wang, X.J.; Srinivasan-Rao, T.; Batchelor, K.

    1995-01-01

    The initial experimental results of the Brookhaven accelerator test facility (ATF) in-line injector is presented. The ATF in-line injector employed a full copper RF gun with a pair of solenoid magnets for emittance compensation. The maximum acceleration field of the RF gun was measured to be 130 MV/m. The electron yield from the copper cathode was maximized using p- polarized laser and the Schottky effect. The quantum efficiency under optimum conditions was measured to be 0.04%. The measured electron bunch length was less than 11 ps, which agreed with the laser pulse length measurement using a streak camera. The normalized rms. emittance for 0.25 nC charge is 0.9 ± 0.1 mm-mrad, which is almost four times smaller than the emittance predicted by the space-charge effect for a non-emittance compensation photocathode RF gun. The normalized rms for 0.6 nC charge was measured range from 1 to 3 mm-mrad. This measurement was first experimental demonstration of emittance compensation in a high-gradient, S-band photocathode RF gun

  5. Interpretation of PISCES -- A RF antenna system experimental results

    International Nuclear Information System (INIS)

    Rothweil, D.A.; Phelps, D.A.; Doerner, R.

    1995-10-01

    The paper describes experimental data from rf coupling experiments using one to four coil antenna arrays that encircle a linear magnetized plasma column. Experimental results using single turn coil that produce symmetric (i.e. m = 0), dipole (m = 1), and radial rf magnetic fields for coupling to ion waves are compared. By operating without a Faraday shield, it was observed for the first time that the plasma resistive load seen by these different antenna types tends to increase with the number of turns to at least the second power. A four-turn m = 0 coil experienced a record 3--5 Ω loading, corresponding to over 90% power coupling to the plasma. A four-turn m = 1 coil experienced up to 1--1.5 Ω loading, also higher than previous observations. First time observations using a two coil array of m = 0 coil are also reported. As predicted, the loading decreases with increasing phase between coil from 0 degree to 180 degree. Experiments using four coil arrays were difficult to optimize and interpret primarily due to complexity of the manual tuning. To facilitate this optimization in the future, a proposed feedback control system that automatically matches load variations between 0.2 and 10 Ω is described

  6. Experimental and numerical results from hybrid retrofitted photovoltaic panels

    International Nuclear Information System (INIS)

    Rossi, Cecilia; Tagliafico, Luca A.; Scarpa, Federico; Bianco, Vincenzo

    2013-01-01

    Highlights: • The experimental study focuses on the feasibility of hybrid PV/T panels retrofitting. • The critical role of a thin layer of air between PV panel and back plate is evidenced. • The benefit of the addition of a conductive paste layer is analyzed via FEM simulations. • The use of wood ribs to stick the back plate represents a cheap effective solution. - Abstract: The aim of present study is to investigate different methodologies to achieve a better contact between a photovoltaic panel and a thermal plate, in order to cool the PV panel by means of water in the perspective of coupling it with a heat pump. It is believed that this kind of system allows to obtain a higher energy efficiency. The analysis is developed both experimentally and numerically, testing different kinds of configurations in different operating conditions. Simulations are employed to analyze the effect of the variations of the contact resistance between the panel and the thermal plates, demonstrating that the use of a conductive paste increases the overall performance of the panel. Results show interesting possibilities in terms of retrofitting of existing photovoltaic panels by employing very simple solutions, such as to fix the thermal plate on the rear of the panel by means of wood ribs

  7. Automation in dairy cattle milking: experimental results and considerations

    Directory of Open Access Journals (Sweden)

    Marisanna Speroni

    2010-01-01

    Full Text Available The results of two experimental programs financed to the Istituto Sperimentale per la Zootecnia are presented. The objective of the two Italian programs was the verify if automatic milking is a suitable practice for Italian dairy system. Results are summarised and compared to those obtained in other international projects. Results refer to animal behaviour, milk yield, milk quality an animal welfare. In a trial comparing cows milked with an automatic milking system and cows milked in a milking parlour, we observed that when the temperature and humidity are very high cows reduce their activity, have lower milking frequency and milk yield than in cold seasons. In comparison to milking parlour, automatic milking system did not increase milk yield which was affected significantly by season, stage of lactation, parity, season per treatment and parity per treatment. The causes of the negative results obtained by this group and by other international groups are discussed. We also presented the results obtained in four trials thereby four appetizers or flavourings were tested to improve efficiency of automatic milking system. Comparing the two milking systems, automatic milking determined a worsening of milk quality, but from these data is not possible to exclude the possibility to use automatic milking for Grana Padano and Parmigiano Reggiano-type cheeses. Animal welfare is not negatively influenced by automatic milking system, which has the potentiality to improve the control and care of cows.

  8. Radiation effects modeling and experimental data on I2L devices

    International Nuclear Information System (INIS)

    Long, D.M.; Repper, C.J.; Ragonese, L.J.; Yang, N.T.

    1976-01-01

    This paper reports on an Integrated Injection Logic (I 2 L) radiation effects model which includes radiation effects phenomena. Twenty-five individual current components were identified for an I 2 L logic gate by assuming wholly vertical or wholly horizontal current flow. Equations were developed for each component in terms of basic parameters such as doping profiles, distances, and diffusion lengths, and set up on a computer for specific logic cell configurations. For neutron damage, the model shows excellent agreement with experimental data. Reactor test results on GE I 2 L samples showed a neutron hardness level in the range of 6 x 10 12 to 3 x 10 13 n/cm 2 (1 MeV Eq), and cobalt-60 tests showed a total dose hardness of 6 x 10 4 to greater than 1 x 10 6 Rads(Si) (all device types at an injection current of 50 microamps per gate). It was found that significant hardness improvements could be achieved by: (a) diffusion profile variation, (b) utilizing a tight N + collar around the cell, and (c) locating the collector close to the injector. Flash X-ray tests showed a transient logic upset threshold of 1 x 10 9 Rads(Si)/sec for a 28 ns pulse, and a survival level greater than 2 x 10 12 Rads(Si)/sec

  9. Compliant actuation based on dielectric elastomers for a force-feedback device: modeling and experimental evaluation

    Directory of Open Access Journals (Sweden)

    R. Vertechy

    2013-01-01

    Full Text Available Thanks to their large power densities, low costs and shock-insensitivity, Dielectric Elastomers (DE seem to be a promising technology for the implementation of light and compact force-feedback devices such as, for instance, haptic interfaces. Nonetheless, the development of these kinds of DE-based systems is not trivial owing to the relevant dissipative phenomena that affect the DE when subjected to rapidly changing deformations. In this context, the present paper addresses the development of a force feedback controller for an agonist-antagonist linear actuator composed of a couple of conically-shaped DE films and a compliant mechanism behaving as a negative-rate bias spring. The actuator is firstly modeled accounting for the visco-hyperelastic nature of the DE material. The model is then linearized and employed for the design of a force controller. The controller employs a position sensor, which determines the actuator configuration, and a force sensor, which measures the interaction force that the actuator exchanges with the environment. In addition, an optimum full-state observer is also implemented, which enables both accurate estimation of the time-dependent behavior of the elastomeric material and adequate suppression of the sensor measurement noise. Preliminary experimental results are provided to validate the proposed actuator-controller architecture.

  10. Experimental evaluation of torsional fatigue strength of welded bellows and application to design of fusion device

    International Nuclear Information System (INIS)

    Takatsu, Hideyuki; Yamamoto, Masahiro; Shimizu, Masatsugu; Suzuki, Kazuo; Sonobe, Tadashi; Hayashi, Yuzo; Mizuno, Gen-ichiro.

    1984-01-01

    Torsional fatigue strength of the welded bellows was evaluated experimentally, aiming the application to a port of a fusion device. The welded bellows revealed elastic torsional buckling and spiral distorsion even under a small angle of torsion. Twisting load never leads the welded bellows to fracture easily so far as the angle of torsion is not excessively large, and the welded bellows has the torsional fatigue strength much larger than that expected so far. Two formulae were proposed to evaluate the stress of the welded bellows under the forced angle of torsion; shearing stress evaluation formula in the case that torsional buckling does not occur and the axial bending stress evaluation formula in the case that torsional buckling occurs. And the results of the torsional fatigue experiments showed that the former is reasonably conservative and simulates the actual behavior of the welded bellows better than the latter in the high cycle fatigue region and vice versa in the low cycle fatigue region from the viewpoint of the mechanical design. The present evaluation method of the torsional fatigue strength was applied to the welded bellows for the port of the JT-60 vacuum vessel and its structural integrity was confirmed under the design load condition. (author)

  11. Experimental installation of refrigeration solar-first results; Instalacion experimental de refrigeracion solar-primeros resultados

    Energy Technology Data Exchange (ETDEWEB)

    Moone, C.; Guallar, J.; Alonso, S.; Palacin, F.

    2008-07-01

    In this article they are and the first results of an installation of solar refrigeration composed by a field of flat solar collector are analysed and absorption chillers of simple effect (BrLi-H{sub 2}O), used to give cold to a gymnasium of the university sport pavilion. The data correspond to the registered experimental values during the summer of 2007 (months of June, Julio and August). (Author)

  12. Blanking and piercing theory, applications and recent experimental results

    International Nuclear Information System (INIS)

    Zaid, A. I. O.

    2013-01-01

    Blanking and piercing are manufacturing processes by which certain geometrical shapes are sheared off a sheet metal. If the sheared off part is the one required, the processes referred to as blanking and if the remaining part in the sheet is the one required, the process is referred to as piercing. In this paper, the theory and practice of these processes are reviewed and discussed The main parameters affecting these processes are presented and discussed. These include: the radial clearance percentage, punch and die geometrical parameters, for example punch and die profile radii. The above mentioned parameters on the force and energy required to effect blanking together with their effect on the quality of the products are also presented and discussed. Recent experimental results together with photomacrographs and photomicrographs are also included and discussed. Finally, the effect of punch and die wear on the quality of the blanks is also given and discussed. (author)

  13. Blanking and piercing theory, applications and recent experimental results

    International Nuclear Information System (INIS)

    Zaid, Adnan l O

    2014-01-01

    Blanking and piercing are manufacturing processes by which certain geometrical shapes are sheared off a sheet metal. If the sheared off part is the one required, the processes referred to as blanking and if the remaining part in the sheet is the one required, the process is referred to as piercing. In this paper, the theory and practice of these processes are reviewed and discussed The main parameters affecting these processes are presented and discussed. These include: the radial clearance percentage, punch and die geometrical parameters, for example punch and die profile radii. The abovementioned parameters on the force and energy required to effect blanking together with their effect on the quality of the products are also presented and discussed. Recent experimental results together with photomacrographs and photomicrographs are also included and discussed. Finally, the effect of punch and die wear on the quality of the blanks is alsogiven and discussed

  14. Experimental results of some cluster tests in NSRR

    International Nuclear Information System (INIS)

    Kobayashi, Shinsho; Ohnishi, Nobuaki; Yoshimura, Tomio; Lussie, W.G.

    1978-01-01

    The NSRR programme is in progress in JAERI using a pulsed reactor to evaluate the behavior of reactor fuels under reactivity accident conditions. This report describes briefly the experimental results and preliminary analysis of two cluster tests. In the cluster configuration of five fuel rods, the power distribution in outer fuel rods are not symmetric due to neutron absorption in central fuel rod. The cladding temperature on the exterior boundaries of the cluster is higher than that in interior. Good agreement was obtained between the calculated and measured cladding temperature histories. In the 3.8$ excess reactivity test, cluster averaged energy deposition of 237 cal/g.UO 2 , cladding melting and deformation were limited to the portions of the fuel rods that were on the exterior boundaries of the cluster. (auth.)

  15. An Electrically Actuated Microbeam-Based MEMS Device: Experimental and Theoretical Investigation

    KAUST Repository

    Ruzziconi, Laura

    2017-11-03

    The present paper deals with the dynamic behavior of a microelectromechanical systems (MEMS). The device consists of a clamped-clamped microbeam electrostatically and electrodynamically actuated. Our objective is to develop a theoretical analysis, which is able to describe and predict all the main relevant aspects of the experimental response. In the first part of the paper an extensive experimental investigation is conducted. The microbeam is perfectly straight. The first three experimental natural frequencies are identified and the nonlinear dynamics are explored at increasing values of electrodynamic excitation. Several backward and forward frequency sweeps are acquired. The nonlinear behavior is highlighted. The experimental data show the coexistence of the nonresonant and the resonant branch, which perform a bending toward higher frequencies values before undergoing jump or pull-in dynamics. This kind of bending is not particularly common in MEMS. In the second part of the paper, a theoretical single degree-of-freedom model is derived. The unknown parameters are extracted and settled via parametric identification. A single mode reduced-order model is considered, which is obtained via the Galerkin technique. To enhance the computational efficiency, the contribution of the electric force term is computed in advance and stored in a table. Extensive numerical simulations are performed at increasing values of electrodynamic excitation. They are observed to properly predict all the main nonlinear features arising in the device response. This occurs not only at low values of electrodynamic excitation, but also at higher ones

  16. [Experimental results of erbium:YAG laser vitrectomy].

    Science.gov (United States)

    Mrochen, M; Petersen, H; Wüllner, C; Seiler, T

    1998-01-01

    Vitrectomy performed by conventional guillotine devices includes the risk of mechanical damage to retina as well as other ocular structures. The present study aims to investigate the efficacy of the Er:YAG laser for vitreous liquefaction. Vitreous liquefaction by means of Er:YAG laser pulses was performed using a special handpiece. The output of an Er:YAG laser operating at 2.94 microns was coupled into a ZrF optical fibre (length 2 m) which ended inside a cavity located at the quartz tip (diameter 320 microns) of the handpiece where tissue ablation took place. The viscosity of the liquefied vitreous was determined by rotation viscosimetry and compared to liquefied vitreous obtained by mechanical vitrectomy. In addition, the aspiration flow (ml/min) was correlated to the repetition/cutting rate of the laser and the cutter. The temperature rise at the handpiece was recorded with a micro thermocouple. The cutting threshold was determined to 5 mJ +/- 3 mJ at a pulse duration of 200 microseconds. The viscosity of the vitreous liquefied with the Er:YAG laser was 31 +/- 10 mPa s which is similar to the results of mechanical vitrectomy (42 +/- 19 mPa s) but significant less than that of normal vitreous (880 +/- 280 mPa s). The aspiration of the laser handpiece in dependence to the repetition rate increases linear up to 2.6 ml/min at 30 Hz. The temperature increase at the handpiece was < 1 K under vitrectomy conditions (aspiration and irrigation) with an averaged laser power of 0.3 W (10 mJ at 30 Hz). The decreased vacuum forces used by the laser vitrectomy system may result in less mechanical stress to the retina as well as intravitreal structures which may be attached to it. An Er:YAG laser vitrectomy system may offer the potential of fewer complications during vitrectomy.

  17. Experimental Results for Direction of Arrival Estimation with a Single Acoustic Vector Sensor in Shallow Water

    Directory of Open Access Journals (Sweden)

    Alper Bereketli

    2015-01-01

    Full Text Available We study the performances of several computationally efficient and simple techniques for estimating direction of arrival (DOA of an underwater acoustic source using a single acoustic vector sensor (AVS in shallow water. Underwater AVS is a compact device, which consists of one hydrophone and three accelerometers in a packaged form, measuring scalar pressure and three-dimensional acceleration simultaneously at a single position. A very controlled experimental setup is prepared to test how well-known techniques, namely, arctan-based, intensity-based, time domain beamforming, and frequency domain beamforming methods, perform in estimating DOA of a source in different circumstances. Experimental results reveal that for almost all cases beamforming techniques perform best. Moreover, arctan-based method, which is the simplest of all, provides satisfactory results for practical purposes.

  18. Internal wave emission from baroclinic jets: experimental results

    Science.gov (United States)

    Borcia, Ion D.; Rodda, Costanza; Harlander, Uwe

    2016-04-01

    Large-scale balanced flows can spontaneously radiate meso-scale inertia-gravity waves (IGWs) and are thus in fact unbalanced. While flow-dependent parameterizations for the radiation of IGWs from orographic and convective sources do exist, the situation is less developed for spontaneously emitted IGWs. Observations identify increased IGW activity in the vicinity of jet exit regions. A direct interpretation of those based on geostrophic adjustment might be tempting. However, directly applying this concept to the parameterization of spontaneous imbalance is difficult since the dynamics itself is continuously re-establishing an unbalanced flow which then sheds imbalances by GW radiation. Examining spontaneous IGW emission in the atmosphere and validating parameterization schemes confronts the scientist with particular challenges. Due to its extreme complexity, GW emission will always be embedded in the interaction of a multitude of interdependent processes, many of which are hardly detectable from analysis or campaign data. The benefits of repeated and more detailed measurements, while representing the only source of information about the real atmosphere, are limited by the non-repeatability of an atmospheric situation. The same event never occurs twice. This argues for complementary laboratory experiments, which can provide a more focused dialogue between experiment and theory. Indeed, life cycles are also examined in rotating-annulus laboratory experiments. Thus, these experiments might form a useful empirical benchmark for theoretical and modeling work that is also independent of any sort of subgrid model. In addition, the more direct correspondence between experimental and model data and the data reproducibility makes lab experiments a powerful testbed for parameterizations. Here we show first results from a small rotating annulus experiments and we will further present our new experimental facility to study wave emission from jets and fronts.

  19. Experimental Results of Guided Wave Travel Time Tomography

    Science.gov (United States)

    Volker, Arno; Mast, Arjan; Bloom, Joost

    2010-02-01

    Corrosion is one of the industries major issues regarding the integrity of assets. Currently inspections are conducted at regular intervals to ensure a sufficient integrity level of these assets. Both economical and social requirements are pushing the industry to even higher levels of availability, reliability and safety of installations. The concept of predictive maintenance using permanent sensors that monitor the integrity of an installation is an interesting addition to the current method of periodic inspections reducing uncertainty and extending inspection intervals. Guided wave travel time tomography is a promising method to monitor the wall thickness quantitatively over large areas. Obviously the robustness and reliability of such a monitoring system is of paramount importance. Laboratory experiments have been carried out on a 10″ pipe with a nominal wall thickness of 8 mm. Multiple, inline defects have been created with a realistic morphology. The depth of the defects was increased stepwise from 0.5 mm to 2 mm. Additionally the influences of the presence of liquid inside the pipe and surface roughness have been evaluated as well. Experimental results show that this method is capable of providing quantitative wall thickness information over a distance of 4 meter, with a sufficient accuracy such that results can be used for trending. The method has no problems imaging multiple defects.

  20. Theoretical and Experimental Results Regarding LENR/CF

    International Nuclear Information System (INIS)

    Robert W. Bass; Wm. Stan Gleeson

    2000-01-01

    We challenge the predominant view that low-energy nuclear reactions (LENRs) are prohibited by standard quantum mechanics (QM). This view, supposedly based on standard nuclear theory, need not apply in condensed-matter environments. These considerations indicate that seemingly novel experimental evidence of rapid aneutronic bulk-process transmutation, at extraordinarily low-energy levels, in a simple electrochemical reactor, can occur. This explains: (a) induced rapid decay of radioactive thorium into stable nuclides, e.g., Cu and (b) resulting, anomalous distribution of Cu isotopes. We reexamine arguments of Peebles cited as evidence that standard QM 'forbids' cold fusion (CF). We note oversimplifications in those and present an alternative, more sophisticated calculation (see Bass, Refs. 3 through 8) demonstrating that conventional wisdom about impenetrability of the 'Coulomb barrier' fails as a result of periodic-order-induced resonance. We also examine empirical evidence. In three independent tests of an LENR electrolysis cell, using different I-V-T (current/voltage/time) protocols, the percentage of radiation reduction (RR) transmutation achieved η=[23%, 50%, 83%] versus expended energy E=[0.6535, 32.5, 74.6] (Watt-hours), obtained by numerical integration of recorded product I · V for processing time T, provides near-perfect straight-line correlation: η=α·E + η 0 , α=0.8105, η 0 =22.888, (0.65 < E < 0.75)

  1. Theoretical analysis of experimental results on SG-1 FEL

    International Nuclear Information System (INIS)

    Yang Zhenhua; Wu Shangqing; Tian Shihong; Dong Zhiwei; Wu Yupu

    1994-01-01

    In order to study the SG-1 FEL and the beam transport thoroughly, and draw certain quantitative conclusions, we developed 3-D WAGFEL code to describe the FEL evolution and 3-D CEBQ code to describe the beam transport. The CEBQ code can simulate the 3-D transport of the electron beam in the modulation section with linear approximation of space charge. According to the first ASE experiments results, the LIA provided a 2 kA, 3.0 MeV beam with a normalized emittance of 0.6 πrad·cm, an energy spread (FWHM) of 4%, resulting in a beam brightness nearly 10 8 A/(πm·rad) 2 . The numerical simulation showed that the quality of the beam was good enough to abandon the 9-m long beam line and substitute it with a 2-m long drifting and focusing region. The second series of ASE and amplifier experiments began in October 1992. The beam transport section was modified. The ASE output power, the amplifier output power and detuning curve was measured. We analysed the experimental results using the WAGFEL and CEBQ codes with parameters equal to those of experiments. Firstly we followed 4096 electrons to simulate the transport process of the beam in the beam line under the condition of I = 2 kA, r b = 1 cm, γ = 6.8, Δγ/γ 4%, ε rms = 0.6 (πrad·cm). Through the simulation, we predicted that the beam current injected into the wiggler was about 611 A. Based on these beam parameters at the entrance of the wiggler, we simulated the FEL process with P in = 300 W. The results are also in Fig.7,8,9

  2. Quality index of radiological devices: results of one year of use.

    Science.gov (United States)

    Tofani, Alessandro; Imbordino, Patrizia; Lecci, Antonio; Bonannini, Claudia; Del Corona, Alberto; Pizzi, Stefano

    2003-01-01

    The physical quality index (QI) of radiological devices summarises in a single numerical value between 0 and 1 the results of constancy tests. The aim of this paper is to illustrate the results of the use of such an index on all public radiological devices in the Livorno province over one year. The quality index was calculated for 82 radiological devices of a wide range of types by implementing its algorithm in a spreadsheet-based software for the automatic handling of quality control data. The distribution of quality index values was computed together with the associated statistical quantities. This distribution is strongly asymmetrical, with a sharp peak near the highest QI values. The mean quality index values for the different types of device show some inhomogeneity: in particular, mammography and panoramic dental radiography devices show far lower quality than other devices. In addition, our analysis has identified the parameters that most frequently do not pass the quality tests for each type of device. Finally, we sought some correlation between quality and age of the device, but this was poorly significant. The quality index proved to be a useful tool providing an overview of the physical conditions of radiological devices. By selecting adequate QI threshold values for, it also helps to decide whether a given device should be upgraded or replaced. The identification of critical parameters for each type of device may be used to improve the definition of the QI by attributing greater weights to critical parameters, so as to better address the maintenance of radiological devices.

  3. Experimental verification of electrostatic boundary conditions in gate-patterned quantum devices

    Science.gov (United States)

    Hou, H.; Chung, Y.; Rughoobur, G.; Hsiao, T. K.; Nasir, A.; Flewitt, A. J.; Griffiths, J. P.; Farrer, I.; Ritchie, D. A.; Ford, C. J. B.

    2018-06-01

    In a model of a gate-patterned quantum device, it is important to choose the correct electrostatic boundary conditions (BCs) in order to match experiment. In this study, we model gated-patterned devices in doped and undoped GaAs heterostructures for a variety of BCs. The best match is obtained for an unconstrained surface between the gates, with a dielectric region above it and a frozen layer of surface charge, together with a very deep back boundary. Experimentally, we find a  ∼0.2 V offset in pinch-off characteristics of 1D channels in a doped heterostructure before and after etching off a ZnO overlayer, as predicted by the model. Also, we observe a clear quantised current driven by a surface acoustic wave through a lateral induced n-i-n junction in an undoped heterostructure. In the model, the ability to pump electrons in this type of device is highly sensitive to the back BC. Using the improved boundary conditions, it is straightforward to model quantum devices quite accurately using standard software.

  4. Experimental demonstration of subwavelength domino plasmon devices for compact high-frequency circuit.

    Science.gov (United States)

    Ma, Y G; Lan, L; Zhong, S M; Ong, C K

    2011-10-24

    In optical frequency, surface plasmons of metal provide us a prominent way to build compact photonic devices or circuits with non-diffraction limit. It is attributed by their extraordinary electromagnetic confining effect. But in the counterpart of lower frequencies, plasmonics behavior of metal is screened by eddy current induced in a certain skin depth. To amend this, spoof plasmons engineered by artificial structures have been introduced to mimic surface plasmons in these frequencies. But it is less useful for practical application due to their weak field confinement as manifested by large field decaying length in the upper dielectric space. Recently, a new type of engineered plasmons, domino plasmon was theoretically proposed to produce unusual field confinement and waveguiding capabilities that make them very attractive for ultra-compact device applications [Opt. Exp. 18, 754-764 (2010)]. In this work, we implemented these ideas and built three waveguiding devices based on domino plasmons. Their strong capabilities to produce versatile and ultra-compact devices with multiple electromagnetic functions have been experimentally verified in microwaves. And that can be extended to THz regime to pave the way for a new class of integrated wave circuits. © 2011 Optical Society of America

  5. Size effects in ductile cellular solids. Part II : experimental results

    NARCIS (Netherlands)

    Andrews, E.W.; Gioux, G.; Onck, P.; Gibson, L.J.

    2001-01-01

    There is increasing interest in the use of metallic foams in a variety of applications, including lightweight structural sandwich panels and energy absorption devices. In such applications, the mechanical response of the foams is of critical importance. In this study, we have investigated the effect

  6. Design and experimental results of coaxial circuits for gyroklystron amplifiers

    International Nuclear Information System (INIS)

    Flaherty, M.K.E.; Lawson, W.; Cheng, J.; Calame, J.P.; Hogan, B.; Latham, P.E.; Granatstein, V.L.

    1994-01-01

    At the University of Maryland high power microwave source development for use in linear accelerator applications continues with the design and testing of coaxial circuits for gyroklystron amplifiers. This presentation will include experimental results from a coaxial gyroklystron that was tested on the current microwave test bed, and designs for second harmonic coaxial circuits for use in the next generation of the gyroklystron program. The authors present test results for a second harmonic coaxial circuit. Similar to previous second harmonic experiments the input cavity resonated at 9.886 GHz and the output frequency was 19.772 GHz. The coaxial insert was positioned in the input cavity and drift region. The inner conductor consisted of a tungsten rod with copper and ceramic cylinders covering its length. Two tungsten rods that bridged the space between the inner and outer conductors supported the whole assembly. The tube produced over 20 MW of output power with 17% efficiency. Beam interception by the tungsten rods resulted in minor damage. Comparisons with previous non-coaxial circuits showed that the coaxial configuration increased the parameter space over which stable operation was possible. Future experiments will feature an upgraded modulator and beam formation system capable of producing 300 MW of beam power. The fundamental frequency of operation is 8.568 GHz. A second harmonic coaxial gyroklystron circuit was designed for use in the new system. A scattering matrix code predicts a resonant frequency of 17.136 GHz and Q of 260 for the cavity with 95% of the outgoing microwaves in the desired TE032 mode. Efficiency studies of this second harmonic output cavity show 20% expected efficiency. Shorter second harmonic output cavity designs are also being investigated with expected efficiencies near 34%

  7. Experimental characterization and analysis of the BITalino platforms against a reference device.

    Science.gov (United States)

    Batista, Diana; Silva, Hugo; Fred, Ana

    2017-07-01

    Low-cost hardware platforms for biomedical engineering are becoming increasingly available, which empower the research community in the development of new projects in a wide range of areas related with physiological data acquisition. Building upon previous work by our group, this work compares the quality of the data acquired by means of two different versions of the multimodal physiological computing platform BITalino, with a device that can be considered a reference. We acquired data from 5 sensors, namely Accelerometry (ACC), Electrocardiography (ECG), Electroencephalography (EEG), Electrodermal Activity (EDA) and Electromyography (EMG). Experimental evaluation shows that ACC, ECG and EDA data are highly correlated with the reference in what concerns the raw waveforms. When compared by means of their commonly used features, EEG and EMG data are also quite similar across the different devices.

  8. Experimental results for an experimental condensation heat exchanger with a spiral minichanel tube. Comparison to numerical imulations

    Directory of Open Access Journals (Sweden)

    Hrubý J.

    2013-04-01

    Full Text Available The paper describes new results for an experimental heat exchanger equipped with a single corrugated capillary tube, basic information about the measurements and the experimental setup. Some of the results were compared with numerical simulations.

  9. Fluid force predictions and experimental measurements for a magnetically levitated pediatric ventricular assist device.

    Science.gov (United States)

    Throckmorton, Amy L; Untaroiu, Alexandrina; Lim, D Scott; Wood, Houston G; Allaire, Paul E

    2007-05-01

    The latest generation of artificial blood pumps incorporates the use of magnetic bearings to levitate the rotating component of the pump, the impeller. A magnetic suspension prevents the rotating impeller from contacting the internal surfaces of the pump and reduces regions of stagnant and high shear flow that surround fluid or mechanical bearings. Applying this third-generation technology, the Virginia Artificial Heart Institute has developed a ventricular assist device (VAD) to support infants and children. In consideration of the suspension design, the axial and radial fluid forces exerted on the rotor of the pediatric VAD were estimated using computational fluid dynamics (CFD) such that fluid perturbations would be counterbalanced. In addition, a prototype was built for experimental measurements of the axial fluid forces and estimations of the radial fluid forces during operation using a blood analog mixture. The axial fluid forces for a centered impeller position were found to range from 0.5 +/- 0.01 to 1 +/- 0.02 N in magnitude for 0.5 +/- 0.095 to 3.5 +/- 0.164 Lpm over rotational speeds of 6110 +/- 0.39 to 8030 +/- 0.57% rpm. The CFD predictions for the axial forces deviated from the experimental data by approximately 8.5% with a maximum difference of 18% at higher flow rates. Similarly for the off-centered impeller conditions, the maximum radial fluid force along the y-axis was found to be -0.57 +/- 0.17 N. The maximum cross-coupling force in the x direction was found to be larger with a maximum value of 0.74 +/- 0.22 N. This resulted in a 25-35% overestimate of the radial fluid force as compared to the CFD predictions; this overestimation will lead to a far more robust magnetic suspension design. The axial and radial forces estimated from the computational results are well within a range over which a compact magnetic suspension can compensate for flow perturbations. This study also serves as an effective and novel design methodology for blood pump

  10. Comprehensive Evaluation of Algal Biofuel Production: Experimental and Target Results

    Directory of Open Access Journals (Sweden)

    Colin M. Beal

    2012-06-01

    Full Text Available Worldwide, algal biofuel research and development efforts have focused on increasing the competitiveness of algal biofuels by increasing the energy and financial return on investments, reducing water intensity and resource requirements, and increasing algal productivity. In this study, analyses are presented in each of these areas—costs, resource needs, and productivity—for two cases: (1 an Experimental Case, using mostly measured data for a lab-scale system, and (2 a theorized Highly Productive Case that represents an optimized commercial-scale production system, albeit one that relies on full-price water, nutrients, and carbon dioxide. For both cases, the analysis described herein concludes that the energy and financial return on investments are less than 1, the water intensity is greater than that for conventional fuels, and the amounts of required resources at a meaningful scale of production amount to significant fractions of current consumption (e.g., nitrogen. The analysis and presentation of results highlight critical areas for advancement and innovation that must occur for sustainable and profitable algal biofuel production can occur at a scale that yields significant petroleum displacement. To this end, targets for energy consumption, production cost, water consumption, and nutrient consumption are presented that would promote sustainable algal biofuel production. Furthermore, this work demonstrates a procedure and method by which subsequent advances in technology and biotechnology can be framed to track progress.

  11. Laser long-range remote-sensing program experimental results

    Science.gov (United States)

    Highland, Ronald G.; Shilko, Michael L.; Fox, Marsha J.; Gonglewski, John D.; Czyzak, Stanley R.; Dowling, James A.; Kelly, Brian; Pierrottet, Diego F.; Ruffatto, Donald; Loando, Sharon; Matsuura, Chris; Senft, Daniel C.; Finkner, Lyle; Rae, Joe; Gallegos, Joe

    1995-12-01

    A laser long range remote sensing (LRS) program is being conducted by the United States Air Force Phillips Laboratory (AF/PL). As part of this program, AF/PL is testing the feasibility of developing a long path CO(subscript 2) laser-based DIAL system for remote sensing. In support of this program, the AF/PL has recently completed an experimental series using a 21 km slant- range path (3.05 km ASL transceiver height to 0.067 km ASL target height) at its Phillips Laboratory Air Force Maui Optical Station (AMOS) facility located on Maui, Hawaii. The dial system uses a 3-joule, (superscript 13)C isotope laser coupled into a 0.6 m diameter telescope. The atmospheric optical characterization incorporates information from an infrared scintillometer co-aligned to the laser path, atmospheric profiles from weather balloons launched from the target site, and meteorological data from ground stations at AMOS and the target site. In this paper, we report a description of the experiment configuration, a summary of the results, a summary of the atmospheric conditions and their implications to the LRS program. The capability of such a system for long-range, low-angle, slant-path remote sensing is discussed. System performance issues relating to both coherent and incoherent detection methods, atmospheric limitations, as well as, the development of advanced models to predict performance of long range scenarios are presented.

  12. Experimental result of poloidal limiter baking of Aditya tokamak

    International Nuclear Information System (INIS)

    Jadeja, K.A.; Arambhadiya, B.G.; Bhatt, S.B.; Bora, D.

    2005-01-01

    In tokamak Aditya, Poloidal limiter function as the operational limiter and are subjected to very high particles load and heat flux during plasma discharge. In addition, Poloidal limiter is the first material surface to come in contact with the hot plasma. In plasma discharge, the impurity generations from limiter are mostly by adsorbed particles. The baking of limiter provides high degassing rate and thermal desorption of adsorbed particles of limiter to reduce impurities from the limiter tiles. The series of experiments are done with different conditions like, Baking of limiter SS ring by heating element with and without limiter tiles in atmosphere and vacuum. Than Poloidal limiter is structured with 14 numbers of graphite tiles and electrical isolated to the vessel and support structure. As a heating element and for electrical isolation, Nychrome wire and ceramic block with ceramic tubes are used. In addition, Thermo couple and two DC power supply (0-10 Ampere) are used for limiter baking. Mass analyzer gives partial pressures of different species to observe effect of limiter baking. For the period of Poloidal limiter baking in Aditya, the partial pressures of different species like hydrogen, water vapor, and oxygen are extremely increased with time duration. This paper presents series of experimental results of poloidal limiter baking. (author)

  13. Acoustic analysis in Mudejar-Gothic churches: experimental results.

    Science.gov (United States)

    Galindo, Miguel; Zamarreño, Teófilo; Girón, Sara

    2005-05-01

    This paper describes the preliminary results of research work in acoustics, conducted in a set of 12 Mudejar-Gothic churches in the city of Seville in the south of Spain. Despite common architectural style, the churches feature individual characteristics and have volumes ranging from 3947 to 10 708 m3. Acoustic parameters were measured in unoccupied churches according to the ISO-3382 standard. An extensive experimental study was carried out using impulse response analysis through a maximum length sequence measurement system in each church. It covered aspects such as reverberation (reverberation times, early decay times), distribution of sound levels (sound strength); early to late sound energy parameters derived from the impulse responses (center time, clarity for speech, clarity, definition, lateral energy fraction), and speech intelligibility (rapid speech transmission index), which all take both spectral and spatial distribution into account. Background noise was also measured to obtain the NR indices. The study describes the acoustic field inside each temple and establishes a discussion for each one of the acoustic descriptors mentioned by using the theoretical models available and the principles of architectural acoustics. Analysis of the quality of the spaces for music and speech is carried out according to the most widespread criteria for auditoria.

  14. Controlled Nuclear Fusion Research, September 1965: Review Of Experimental Results

    Energy Technology Data Exchange (ETDEWEB)

    Spitzer, Lyman Jr. [Princeton University, Princeton, NJ (United States)

    1966-04-15

    To my way of thinking the most significant milestone of the present meeting is the substantial body of evidence that has been presented on the hydromagnetic stabilization of open-ended systems. The success of minimum magnetic-field ('minimum-B') configurations in stabilizing a plasma marks one more area where theory and experiment in the field of plasma physics have been brought together with gratifying results. Let me go back a little into history and discuss the gradual growth of our information on hydromagnetic instabilities generally. Many of you will remember that hydromagnetic theory was applied to the self-pinched discharge in the early years of the controUed fusion programme. The predictions of this theory were very shortly fulfilled by the observations; the effects were so unmistakable that it was not difficult to compare the theory with the observations. On the streak pictures of the linear or toroidal discharges that were obtained in those early years one saw clearly the diffuse plasma column, which first contracted to a narrow filament and then started to distort and kink until finally it hit the wall. Under some conditions the plasma was observed to break up into a series of blobs like a string of sausages. Since the behaviour was exactly what the theory had predicted, it took no very great experimental wisdom to conclude that observations had confirmed theory.

  15. Experimental results on transport and focusing of laser accelerated protons

    Energy Technology Data Exchange (ETDEWEB)

    Busold, Simon; Deppert, Oliver; Roth, Markus [TU Darmstadt, IKP, Schlossgartenstr. 9, 64289 Darmstadt (Germany); Schumacher, Dennis; Blazevic, Abel; Zielbauer, Bernhard; Hofmann, Ingo; Bagnoud, Vincent [GSI Helmholtzzentrum fuer Schwerionenforschung, Planckstr. 1, 64291 Darmstadt (Germany); Brabetz, Christian; Al-Omari, Husam [JWG Universitaet Frankfurt, IAP, Max von Laue Str. 1, 60438 Frankfurt am Main (Germany); Joost, Martin; Kroll, Florian; Cowan, Tom [Helmholtzzentrum Dresden-Rossendorf, Bautzner Landstr. 400, 01328 Dresden (Germany); Collaboration: LIGHT-Collaboration

    2013-07-01

    Irradiation of thin foils with high-intensity laser pulses became a reliable tool during the last decade for producing high-intensity proton bunches in about a pico-second from a sub-millimeter source. However, the energy distribution is of an exponential shape with a currently achievable cut-off energy <100 MeV (TNSA mechanism) and the beam is highly divergent with an energy-dependent envelope-divergence of up to 60 deg. Thus, for most applications it is necessary to be able to capture and control these protons as well as select a specific energy. In the frame of the LIGHT collaboration, experimental studies were done at the PHELIX laser at GSI Darmstadt using a pulsed high-field solenoid and alternatively a permanent magnet quadrupole triplet in order to match the beam for injection into a RF cavity. The beam was characterized at several distances after the source and the results are compared to particle tracking simulations.

  16. Acoustic analysis in Mudejar-Gothic churches: Experimental results

    Science.gov (United States)

    Galindo, Miguel; Zamarreño, Teófilo; Girón, Sara

    2005-05-01

    This paper describes the preliminary results of research work in acoustics, conducted in a set of 12 Mudejar-Gothic churches in the city of Seville in the south of Spain. Despite common architectural style, the churches feature individual characteristics and have volumes ranging from 3947 to 10 708 m3. Acoustic parameters were measured in unoccupied churches according to the ISO-3382 standard. An extensive experimental study was carried out using impulse response analysis through a maximum length sequence measurement system in each church. It covered aspects such as reverberation (reverberation times, early decay times), distribution of sound levels (sound strength); early to late sound energy parameters derived from the impulse responses (center time, clarity for speech, clarity, definition, lateral energy fraction), and speech intelligibility (rapid speech transmission index), which all take both spectral and spatial distribution into account. Background noise was also measured to obtain the NR indices. The study describes the acoustic field inside each temple and establishes a discussion for each one of the acoustic descriptors mentioned by using the theoretical models available and the principles of architectural acoustics. Analysis of the quality of the spaces for music and speech is carried out according to the most widespread criteria for auditoria. .

  17. An experimental device for measurement of gas permeation in solid matrices

    International Nuclear Information System (INIS)

    De Salve, M.; Mazzi, E.; Zucchetti, M.

    1996-01-01

    The inventory in and the permeation through fusion reactor structures of hydrogen and its isotopes play an important role in the machine operation, evolution of material properties, and safety. An experimental and research activity for the determination of permeability (and derived parameters) of gases in solid matrices is described. It uses a gas permeation method, that basically consists in the measure of the time evolution of the gas pressure in a chamber in which vacuum has been previously made (downstream volume). This chamber is separated from another one, full of the gas in exam (upstream volume), by means of a membrane of the material under study. The experimental installation is described. The first stage of the experimental activity has dealt with the set-up of the device, the volume calibration, and the definition of the parameters range for which the installation can give reliable measurements. The subsequent stage of the activity has consisted in the measurement of the permeability, and then of the diffusion coefficient, of nitrogen in some materials at room temperature. Concurrently with the experimental activity, a model has been set-up and implemented in a computer code: this code permits to evaluate the time evolution of the pressure in the downstream chamber. With this code, using the measured parameters, the time evolution of the pressure experimentally measured has been satisfactorily reproduced. (author)

  18. Energy-resolved computed tomography: first experimental results

    International Nuclear Information System (INIS)

    Shikhaliev, Polad M

    2008-01-01

    First experimental results with energy-resolved computed tomography (CT) are reported. The contrast-to-noise ratio (CNR) in CT has been improved with x-ray energy weighting for the first time. Further, x-ray energy weighting improved the CNR in material decomposition CT when applied to CT projections prior to dual-energy subtraction. The existing CT systems use an energy (charge) integrating x-ray detector that provides a signal proportional to the energy of the x-ray photon. Thus, the x-ray photons with lower energies are scored less than those with higher energies. This underestimates contribution of lower energy photons that would provide higher contrast. The highest CNR can be achieved if the x-ray photons are scored by a factor that would increase as the x-ray energy decreases. This could be performed by detecting each x-ray photon separately and measuring its energy. The energy selective CT data could then be saved, and any weighting factor could be applied digitally to a detected x-ray photon. The CT system includes a photon counting detector with linear arrays of pixels made from cadmium zinc telluride (CZT) semiconductor. A cylindrical phantom with 10.2 cm diameter made from tissue-equivalent material was used for CT imaging. The phantom included contrast elements representing calcifications, iodine, adipose and glandular tissue. The x-ray tube voltage was 120 kVp. The energy selective CT data were acquired, and used to generate energy-weighted and material-selective CT images. The energy-weighted and material decomposition CT images were generated using a single CT scan at a fixed x-ray tube voltage. For material decomposition the x-ray spectrum was digitally spilt into low- and high-energy parts and dual-energy subtraction was applied. The x-ray energy weighting resulted in CNR improvement of calcifications and iodine by a factor of 1.40 and 1.63, respectively, as compared to conventional charge integrating CT. The x-ray energy weighting was also applied

  19. Nonlinear dynamics of an electrically actuated mems device: Experimental and theoretical investigation

    KAUST Repository

    Ruzziconi, Laura; Ramini, Abdallah H.; Younis, Mohammad I.; Lenci, Stefano

    2013-01-01

    This study deals with an experimental and theoretical investigation of an electrically actuated micro-electromechanical system (MEMS). The experimental nonlinear dynamics are explored via frequency sweeps in a neighborhood of the first symmetric natural frequency, at increasing values of electrodynamic excitation. Both the non-resonant branch, the resonant one, the jump between them, and the presence of a range of inevitable escape (dynamic pull-in) are observed. To simulate the experimental behavior, a single degree-offreedom spring mass model is derived, which is based on the information coming from the experimentation. Despite the apparent simplicity, the model is able to catch all the most relevant aspects of the device response. This occurs not only at low values of electrodynamic excitation, but also at higher ones. Nevertheless, the theoretical predictions are not completely fulfilled in some aspects. In particular, the range of existence of each attractor is smaller in practice than in the simulations. This is because, under realistic conditions, disturbances are inevitably encountered (e.g. discontinuous steps when performing the sweeping, approximations in the modeling, etc.) and give uncertainties to the operating initial conditions. A reliable prediction of the actual (and not only theoretical) response is essential in applications. To take disturbances into account, we develop a dynamical integrity analysis. Integrity profiles and integrity charts are performed. They are able to detect the parameter range where each branch can be reliably observed in practice and where, instead, becomes vulnerable. Moreover, depending on the magnitude of the expected disturbances, the integrity charts can serve as a design guideline, in order to effectively operate the device in safe condition, according to the desired outcome. Copyright © 2013 by ASME.

  20. Nonlinear dynamics of an electrically actuated mems device: Experimental and theoretical investigation

    KAUST Repository

    Ruzziconi, Laura

    2013-11-15

    This study deals with an experimental and theoretical investigation of an electrically actuated micro-electromechanical system (MEMS). The experimental nonlinear dynamics are explored via frequency sweeps in a neighborhood of the first symmetric natural frequency, at increasing values of electrodynamic excitation. Both the non-resonant branch, the resonant one, the jump between them, and the presence of a range of inevitable escape (dynamic pull-in) are observed. To simulate the experimental behavior, a single degree-offreedom spring mass model is derived, which is based on the information coming from the experimentation. Despite the apparent simplicity, the model is able to catch all the most relevant aspects of the device response. This occurs not only at low values of electrodynamic excitation, but also at higher ones. Nevertheless, the theoretical predictions are not completely fulfilled in some aspects. In particular, the range of existence of each attractor is smaller in practice than in the simulations. This is because, under realistic conditions, disturbances are inevitably encountered (e.g. discontinuous steps when performing the sweeping, approximations in the modeling, etc.) and give uncertainties to the operating initial conditions. A reliable prediction of the actual (and not only theoretical) response is essential in applications. To take disturbances into account, we develop a dynamical integrity analysis. Integrity profiles and integrity charts are performed. They are able to detect the parameter range where each branch can be reliably observed in practice and where, instead, becomes vulnerable. Moreover, depending on the magnitude of the expected disturbances, the integrity charts can serve as a design guideline, in order to effectively operate the device in safe condition, according to the desired outcome. Copyright © 2013 by ASME.

  1. An experimental study addressing the use of geoforensic analysis for the exploitation of improvised explosive devices (IEDs).

    Science.gov (United States)

    Wilks, Beth; Morgan, Ruth M; Rose, Neil L

    2017-09-01

    The use of geoforensic analysis in criminal investigations is continuing to develop, with the diversification of analytical techniques, many of which are semi-automated, facilitating prompt analysis of large sample sets at a relatively low cost. Whilst micro-scale geoforensic analysis has been shown to assist criminal investigations including homicide (Concheri et al., 2011 [1]), wildlife crime (Morgan et al., 2006 [2]), illicit drug distribution (Stanley, 1992 [3]), and burglary (Mildenhall, 2006 [4]), its application to the pressing international security threat posed by Improvised Explosive Devices (IEDs) is yet to be considered. This experimental study simulated an IED supply chain from the sourcing of raw materials through to device emplacement. Mineralogy, quartz grain surface texture analysis (QGSTA) and particle size analysis (PSA) were used to assess whether environmental materials were transferred and subsequently persisted on the different components of three pressure plate IEDs. The research also addressed whether these samples were comprised of material from single or multiple geographical provenances that represented supply chain activity nodes. The simulation demonstrated that material derived from multiple activity nodes, was transferred and persisted on device components. The results from the mineralogy and QGSTA illustrated the value these techniques offer for the analysis of mixed provenance samples. The results from the PSA, which produces a bulk signature of the sample, failed to distinguish multiple provenances. The study also considered how the environmental material recovered could be used to generate information regarding the geographical locations the device had been in contact with, in an intelligence style investigation, and demonstrated that geoforensic analysis has the potential to be of value to international counter-IED efforts. It is a tool that may be used to prevent the distribution of large quantities of devices, by aiding the

  2. Experimental investigations of an air curtain device subjected to external perturbations

    International Nuclear Information System (INIS)

    Havet, M.; Rouaud, O.; Solliec, C.

    2003-01-01

    Although plane air jets are often used as dynamic barriers to separate two environments, only a few works have explored their sensitivity to perturbations. We investigated the influence of sharp changes of pressure on the flow field of a device designed to avoid air-borne contamination. Laser tomography and tracer gas experiments clearly indicate that the air curtain is strongly sensitive to perturbations such as draughts. The results highlight that the control of air curtains used in open protection devices should be further investigated

  3. Computer controlled experimental device for investigations of tribological influences in sheet metal forming

    Directory of Open Access Journals (Sweden)

    Milan Djordjevic

    2012-05-01

    Full Text Available Sheet metal forming, especially deep drawing process, is influenced by many factors. Blank holding force and drawbead displacement are two of them that can be controlled during the forming process. For this purpose, electro-hydraulic computerized sheet-metal strip sliding device has been constructed. Basic characteristic of this device is realization of variable contact pressure and drawbead height as functions of time or stripe displacement. There are both, pressure and drawbead, ten linear and nonlinear functions. Additional features consist of the ability to measure drawing force, contact pressure, drawbead displacement etc. Presented in the paper are the device overview and the first results of steel sheet stripe sliding over rounded  drawbead.

  4. COMPUTER CONTROLLED EXPERIMENTAL DEVICE FOR INVESTIGATIONS OF TRIBOLOGICAL INFLUENCES IN SHEET METAL FORMING

    Directory of Open Access Journals (Sweden)

    Tomislav Vujinović

    2012-05-01

    Full Text Available Sheet metal forming, especially deep drawing process is influenced by many factors. Blank holding force and drawbead displacement are two of them that can be controlled during the forming process.For this purpose, an electro-hydraulic computerized sheet-metal strip sliding device has been constructed. The basic characteristic of this device is realization of variable contact pressure and drawbead height as functions of time or stripe displacement. There are both, pressure and drawbead, ten linear and nonlinear functions. Additional features consist of the ability to measure drawing force, contact pressure, drawbead displacement etc.The device overview and first results of steel sheet stripe sliding over rounded drawbead are presented in the paper.

  5. The Captive Helicopter as a Training Device: Experimental Evaluation of a Concept. Technical Report 68-9.

    Science.gov (United States)

    Caro, Paul W., Jr.; And Others

    As part of the Army's effort to use synthetic devices to improve training, researchers evaluated a captive helicopter attached to a ground effects machine. Experimental groups received varying amounts of pre-flight practice tasks designed to develop flight skills, while control groups received no device training. Student flight performance during…

  6. Results of Experimental Study on Flexitime and Family Life.

    Science.gov (United States)

    Winett, Richard A.; Neale, Michael S.

    1980-01-01

    According to two small experimental studies of flexible working hours, federal workers with young children choose to arrive at and depart from work earlier, allowing them to increase the time spent with their families and to engage in recreational, educational, and household activities. (Author/SK)

  7. Alkali Metal Backup Cooling for Stirling Systems - Experimental Results

    Science.gov (United States)

    Schwendeman, Carl; Tarau, Calin; Anderson, William G.; Cornell, Peggy A.

    2013-01-01

    In a Stirling Radioisotope Power System (RPS), heat must be continuously removed from the General Purpose Heat Source (GPHS) modules to maintain the modules and surrounding insulation at acceptable temperatures. The Stirling convertor normally provides this cooling. If the Stirling convertor stops in the current system, the insulation is designed to spoil, preventing damage to the GPHS at the cost of an early termination of the mission. An alkali-metal Variable Conductance Heat Pipe (VCHP) can be used to passively allow multiple stops and restarts of the Stirling convertor. In a previous NASA SBIR Program, Advanced Cooling Technologies, Inc. (ACT) developed a series of sodium VCHPs as backup cooling systems for Stirling RPS. The operation of these VCHPs was demonstrated using Stirling heater head simulators and GPHS simulators. In the most recent effort, a sodium VCHP with a stainless steel envelope was designed, fabricated and tested at NASA Glenn Research Center (GRC) with a Stirling convertor for two concepts; one for the Advanced Stirling Radioisotope Generator (ASRG) back up cooling system and one for the Long-lived Venus Lander thermal management system. The VCHP is designed to activate and remove heat from the stopped convertor at a 19 degC temperature increase from the nominal vapor temperature. The 19 degC temperature increase from nominal is low enough to avoid risking standard ASRG operation and spoiling of the Multi-Layer Insulation (MLI). In addition, the same backup cooling system can be applied to the Stirling convertor used for the refrigeration system of the Long-lived Venus Lander. The VCHP will allow the refrigeration system to: 1) rest during transit at a lower temperature than nominal; 2) pre-cool the modules to an even lower temperature before the entry in Venus atmosphere; 3) work at nominal temperature on Venus surface; 4) briefly stop multiple times on the Venus surface to allow scientific measurements. This paper presents the experimental

  8. Preliminary result on quantitative analysis using Zn-like tungsten EUV spectrum in Large Helical Device

    International Nuclear Information System (INIS)

    Morita, Shigeru; Dong, Chunfeng; Wang, Erhui

    2013-01-01

    Tungsten study through visible, vacuum ultraviolet (VUV) and extreme ultraviolet (EUV) spectroscopy has been recently started in Large Helical Device (LHD) for developing the diagnostic method in International Thermonuclear Experimental Reactor (ITER) and understanding the tungsten transport in helical system. In order to study the tungsten spectra from core plasmas of LHD, several tungsten spectra are observed in EUV range by injecting a carbon pellet with tungsten. Zn-like tungsten spectrum with 4p-4s transition is clearly identified at 60.9Å in high-temperature phase (T_e ≥ 2.3 keV) of NBI discharges in addition to several unresolved transition arrays with 6g-4f, 5g-4f, 5f-4d, 5g-4f, 4f-4d and 4d-4p transitions in range of 10-70Å. Radial profile of the Zn-like tungsten is also successfully observed with enough intensity in order of 10"1"6 photons.cm"-"2.s"-"1. The radial emissivity profile reconstructed from the chord-integrated intensity profile is analyzed with combination of HULLAC code for emission coefficient calculation of the Zn-like transition and impurity transport code included ADPAK code for calculation of ionization and recombination rate coefficients. Thus, a total tungsten ion density of 3.5x10"1"0 cm"-"3 at the plasma center is reasonably obtained in discharge with central electron density of 4x10"1"3 cm"-"3 as the first experimental trial. The present result demonstrates that the Zn-like 4p-4s transition is applicable to the tungsten diagnostics in high-temperature plasmas. (author)

  9. Phase diagram Fe-Sn-Sr. New experimental results

    International Nuclear Information System (INIS)

    Nieva, N; Jimenez, M.J; Gomez, A; Corvalan Moya, C; Arias, D

    2012-01-01

    Zr-based alloys are widely used in nuclear industry due to their specific characteristics. The information of the phase diagrams of the ternary system Fe-Zr-Sn is scarce. In this work we investigate, in a experimental way, the central and the Fe-Sn binary adjacent regions of the Fe-Sn-Zr Gibbs triangle at the temperature of 800 o C. For the experimental work, a set of seven ternary alloys was designed, produced and examined by different complementary techniques. There were performed two types of heat treatments: one of medium and another of long duration. We present a new proposal for the 800 o C isothermal section. The boundaries of the identified phases and the fields of one, two and three phases are indicated in the diagram

  10. Experimental results from a flowing-lithium target

    International Nuclear Information System (INIS)

    Annese, C.E.; Schwartz, K.E.

    1982-01-01

    Hydraulic stability of a free surface lithium jet was demonstrated at 260 0 C and from the middle-vacuum region of 0.01 Pa (10 - 4 Torr) up to 124 kPa (18 psia). The jet is formed by flowing lithium at rates to 0.04 m 3 /s (600 GPM) through a precisely defined nozzle which directs the flow along a curved wall where velocities of up to 17 m/s are attained. This nozzle and curved wall configuration form the basis of the Fusion Materials Irradiation Test (FMIT) Facility lithium target. A full-size experimental model of this target is presently under test with flowing lithium in the Experimental Lithium System (ELS). The FMIT is being developed for the Department of Energy by the Westinghouse Hanford Company at the Hanford Engineering Development Laboratory

  11. Experimentally increasing sedentary behavior results in decreased life satisfaction

    OpenAIRE

    Edwards, Meghan K.; Loprinzi, Paul D.

    2017-01-01

    Background: No study has experimentally manipulated sedentary behavior and evaluated its effect on life satisfaction. Thus, the purpose of this study was to evaluate the effects of a free-living, sedentary behavior-inducing randomized controlled intervention on life satisfaction. Methods: Active, young adults between the ages of 18-35 were recruited and randomly assigned into a sedentary behavior intervention group (n = 26) or a control group (n = 13). The intervention group par...

  12. High temperature pressure water's blowdown into water. Experimental results

    International Nuclear Information System (INIS)

    Ishida, Toshihisa; Kusunoki, Tsuyoshi; Kasahara, Yoshiyuki; Iida, Hiromasa

    1994-01-01

    The purpose of the present experimental study is to clarify the phenomena in blowdown of high temperature and pressure water in pressure vessel into the containment water for evaluation of design of an advanced marine reactor(MRX). The water blown into the containment water flushed and formed steam jet plume. The steam jet condensed in the water, but some stream penetrated to gas phase of containment and contributed to increase of containment pressure. (author)

  13. In-pile experimental device for Sirene thermionic converters; Dispositif d'experimentation en pile des convertisseurs thermoioniques sirene

    Energy Technology Data Exchange (ETDEWEB)

    Bliaux, J; Durand, J; Lazare-Chopard, G [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1969-07-01

    The irradiation device described here, was built for in pile life tests of 100 We SIRENE converters. The nuclear converter is located in a sealed vacuum chamber, which is plugged at the lower end of a coaxial tubing acting as electrical leads. The output power is available on a variable resistive load on the bank of the reactor pool. Thermal, electrical and neutronic parameters of the converter are recorded. Since 1967, two permanent devices allowed five experiments in the swimming pool TRITON (CEN-FAR) and the results, obtained till now, are presented. (authors) [French] Le dispositif d'irradiation SIRENE decrit ici a ete concu en vue d'une etude statistique de performances de convertisseurs thermoioniques nucleaires de puissance unitaire 100 We. Le dispositif doit assurer la bonne marche du convertisseur en pile, permettre le changement de la position verticale du convertisseur dans le coeur, sortir du coeur la puissance electrique convertie sans degradation notable et enregistrer les differents parametres thermiques, electriques et neutroniques du convertisseur. Depuis 1967, deux dispositifs fonctionnent en permanence et ont permis de faire cinq experiences dans le reacteur piscine TRITON du CEN-FAR. Les resultats obtenus jusqu'a present, sont presentes. (auteurs)

  14. Observer Based Sliding Mode Attitude Control: Theoretical and Experimental Results

    Directory of Open Access Journals (Sweden)

    U. Jørgensen

    2011-07-01

    Full Text Available In this paper we present the design of a sliding mode controller for attitude control of spacecraft actuated by three orthogonal reaction wheels. The equilibrium of the closed loop system is proved to be asymptotically stable in the sense of Lyapunov. Due to cases where spacecraft do not have angular velocity measurements, an estimator for the generalized velocity is derived and asymptotic stability is proven for the observer. The approach is tested on an experimental platform with a sphere shaped Autonomous Underwater Vehicle SATellite: AUVSAT, developed at the Norwegian University of Science and Technology.

  15. Hemolysis in a laminar flow-through Couette shearing device: an experimental study.

    Science.gov (United States)

    Boehning, Fiete; Mejia, Tzahiry; Schmitz-Rode, Thomas; Steinseifer, Ulrich

    2014-09-01

    Reducing hemolysis has been one of the major goals of rotary blood pump development and in the investigational phase, the capability of hemolysis estimation for areas of elevated shear stresses is valuable. The degree of hemolysis is determined by the amplitude of shear stress and the exposure time, but to date, the exact hemolytic behavior at elevated shear stresses and potential thresholds for subcritical shear exposure remain vague. This study provides experimental hemolysis data for a set of shear stresses and exposure times to allow better estimations of hemolysis for blood exposed to elevated shearing. Heparinized porcine blood with a hematocrit of 40% was mechanically damaged in a flow-through laminar Couette shear flow at a temperature of 23°C. Four levels of shear stress, 24, 592, 702, and 842 Pa, were replicated at two exposure times, 54 and 873 ms. For the calculation of the shear stresses, an apparent viscosity of 5 mPas was used, which was verified in an additional measurement of the blood viscosity. The hemolysis measurements were repeated four times, whereby all conditions were measured once within the same day and with blood from the same source. Samples were taken at the inlet and outlet of the shear region and an increase in plasma-free hemoglobin was measured. An index of hemolysis (IH) was thereby calculated giving the ratio of free to total hemoglobin. The results are compared with data from previously published studies using a similar shearing device. Hemolysis was found to increase exponentially with shear stress, but high standard deviations existed at measurements with elevated IH. At short exposure times, the IH remained low at under 0.5% for all shear stress levels. For high exposure times, the IH increased from 0.84% at 592 Pa up to 3.57% at the highest shear stress level. Hemolysis was significant for shear stresses above ∼600 Pa at the high exposure time of 873 ms. Copyright © 2014 International Center for Artificial

  16. Design of an experimental device dedicated to the measurement of spallation reactions; Mise au point d'un dispositif experimental pour des mesures exclusives des reactions de spallation

    Energy Technology Data Exchange (ETDEWEB)

    Lafriakh, A

    2005-12-15

    Spallation mechanisms are not yet completely understood, especially because of the difficulty of experimentally disentangling the effects of the different steps of the reaction. In order to understand these mechanisms, we have developed a new experimental device able to perform inclusive measurements. We propose a detection system based on a combination of ionization chambers and proportional counters and on a wall of plastic scintillators to measure light charged particles. In particular the detection of light charged particles is described in detail. In order to validate our device, we have compared our preliminary results obtained on the Fe{sup 56} + p system at 1 GeV/u with inclusive measurements previously obtained at the FRS spectrometer of the GSI facility. A comparison of charge differential cross section shows reasonable agreement. However, our new device allowed extension of those measurements down to Z = 1 and Z = 2. These cross sections are important for material damage studies. Taking into account our error brackets, the evolution of mean longitudinal velocities with respect to residue masses is comparable to that obtained at the FRS. These first results, although preliminary, allow us to validate our experimental device. It is now possible to exploit the strong points of our exclusive measurements, namely correlations between different measured observables. Finally, experimental problems encountered will be taken into account in the future experimental programs, in order to ensure the best measurements conditions.

  17. Overview of Recent DIII-D Experimental Results

    Science.gov (United States)

    Fenstermacher, Max

    2015-11-01

    Recent DIII-D experiments have added to the ITER physics basis and to physics understanding for extrapolation to future devices. ELMs were suppressed by RMPs in He plasmas consistent with ITER non-nuclear phase conditions, and in steady state hybrid plasmas. Characteristics of the EHO during both standard high torque, and low torque enhanced pedestal QH-mode with edge broadband fluctuations were measured, including edge localized density fluctuations with a microwave imaging reflectometer. The path to Super H-mode was verified at high beta with a QH-mode edge, and in plasmas with ELMs triggered by Li granules. ITER acceptable TQ mitigation was obtained with low Ne fraction Shattered Pellet Injection. Divertor ne and Te data from Thomson Scattering confirm predicted drift-driven asymmetries in electron pressure, and X-divertor heat flux reduction and detachment were characterized. The crucial mechanisms for ExB shear control of turbulence were clarified. In collaboration with EAST, high beta-p scenarios were obtained with 80 % bootstrap fraction, high H-factor and stability limits, and large radius ITBs leading to low AE activity. Work supported by the US Department of Energy under DE-FC02-04ER54698 and DE-AC52-07NA27344.

  18. Experimental Investigation on the Behavior of Bracing Damper Systems by Utilizing Metallic Yielding and Recentering Material Devices

    Directory of Open Access Journals (Sweden)

    Jong Wan Hu

    2018-01-01

    Full Text Available With the aim of effectively reducing the structural damage caused by earthquake events, bracing systems equipped with retrofitting damper devices, which take advantage of the energy dissipation and impact absorption, have been widely used in practical construction sites. These bracing dampers, however, have been recognized as expendable supplies for easily replacing the damaged ones after a strong earthquake because they are commonly designed to undergo concentrated force and deformation for the purpose of protecting the main structural members such as the columns and beams. In this paper, the use of new superelastic shape memory alloy (SMA dampers that can partially recover their original configuration is proposed to decrease the repair cost. In addition, the conventional steel dampers used for improving the energy dissipation arising due to metallic yielding are additionally integrated into the bracing member. The behaviors of such bracing systems with the damper devices were reproduced in experimental tests with the cyclic loading history, and then their strength capacity and recentering capability were estimated based on the experiment results. Finally, additional experimental tests were performed by imposing cyclic loading histories with different loading speeds on the superelastic SMA and steel plate damper specimens.

  19. Investigation of Energy Absorption in Aluminum Foam Sandwich Panels By Drop Hammer Test: Experimental Results

    Directory of Open Access Journals (Sweden)

    Mohammad Nouri Damghani

    2016-05-01

    Full Text Available The sandwich panel structures with aluminum foam core and metal surfaces have light weight with high performance in dispersing energy. This has led to their widespread use in the absorption of energy. The cell structure of foam core is subjected to plastic deformation in the constant tension level that absorbs a lot of kinetic energy before destruction of the structure. In this research, by making samples of aluminum foam core sandwich panels with aluminum surfaces, experimental tests of low velocity impact by a drop machine are performed for different velocities and weights of projectile on samples of sandwich panels with aluminum foam core with relative density of 18%, 23%, and 27%. The output of device is acceleration‐time diagram which is shown by an accelerometer located on the projectile. From the experimental tests, the effect of weight, velocity and energy of the projectile and density of the foam on the global deformation, and energy decrease rate of projectile have been studied. The results of the experimental testes show that by increasing the density of aluminum foam, the overall impression is reduced and the slop of energy loss of projectile increases. Also by increasing the velocity of the projectile, the energy loss increases.

  20. Modeling and Experimental Tests of a Mechatronic Device to Measure Road Profiles Considering Impact Dynamics

    DEFF Research Database (Denmark)

    Souza, A.; Santos, Ilmar

    2002-01-01

    of a vehicle and to test its components in laboratory. In this framework a mechanism to measure road profiles is designed and presented. Such a mechanism is composed of two rolling wheels and two long beams attached to the vehicles by means of four Kardan joints. The wheels are kept in contact to the ground...... to highlight that the aim of this device is to independently measure two road profiles, without the influence of the vehicle dynamics where the mechanism is attached. Before the mechatronic mechanism is attached to a real vehicle, its dynamic behavior must be known. A theoretical analysis of the mechanism...... predicts well the mechanism movements. However it was also experimentally observed that the contact between the wheels and the road profile is not permanent. To analyze the non-contact between the wheels and the road, the Newton-Euler´s Method is used to calculate forces and moments of reactions between...

  1. Experimental results on spin physics at the AGS

    International Nuclear Information System (INIS)

    Makdisi, Y.I.

    1986-01-01

    The AGS ran with polarized protons towards the end of 1985 and through the first two months of 1986. This comprised commissioning periods interleaved with two runs for physics at 13.5 GeV/c with beam polarization of 50 to 60%, and 18.5 GeV/c with an average beam polarization of 40%. Later, the AGS polarized beam reached peak energy of 22 GeV/c and polarization of 46%. This article describes the various spin related experimental efforts since the VI Symposium at Marseille. These will be grouped into those using unpolarized beams and the rest are the polarized proton beam users. Afterwards the future of the program is described as extensions of current experiments in addition to other measurements that are yet to be proposed

  2. Experimental MR imaging with Gd-DOTA: Preliminary results

    International Nuclear Information System (INIS)

    Schouman-Claeys, E.; Kien, P.; Caille, J.M.; Bonnemain, B.; Frija, G.

    1986-01-01

    To evaluate the paramagnetic properties of a new gadolinium chelate, Gd-DOTA, in vitro and in vivo MR imaging was performed with a 0.5-T supraconductive magnet. The in vitro study consisted in measuring the MR signal obtained with various concentrations of Gd-DOTA and Gd-DTPA in different solutions. Potentialization of the paramagnetic properties of both DOTA and DTPA can be achieved by deuterium, glycerol, and protein solutions. The in vivo study was performed in rabbits with various experimental lesions. Enhancement of anatomic details was obtained with both Gd-DOTA and Gd-DTPA. There was no significant difference between Gd-DOTA and Gd-DTPA, both for in vitro and in vivo experiments. Gd-DOTA appears to be a potential paramagnetic agent for MR imaging

  3. Waste glass corrosion modeling: Comparison with experimental results

    International Nuclear Information System (INIS)

    Bourcier, W.L.

    1994-01-01

    Models for borosilicate glass dissolution must account for the processes of (1) kinetically-controlled network dissolution, (2) precipitation of secondary phases, (3) ion exchange, (4) rate-limiting diffusive transport of silica through a hydrous surface reaction layer, and (5) specific glass surface interactions with dissolved cations and anions. Current long-term corrosion models for borosilicate glass employ a rate equation consistent with transition state theory embodied in a geochemical reaction-path modeling program that calculates aqueous phase speciation and mineral precipitation/dissolution. These models are currently under development. Future experimental and modeling work to better quantify the rate-controlling processes and validate these models are necessary before the models can be used in repository performance assessment calculations

  4. A first glance at the initial ATF experimental results

    International Nuclear Information System (INIS)

    Carreras, B.A.; Dominguez, N.; Leboeuf, J.N.; Lynch, V.E.; Charlton, L.A.

    1989-05-01

    In the initial phase of ATF operation, the plasma minor radius and the edge rotational transform were reduced by field errors. This caused an effective change of the magnetic configuration: it improved the stability properties but worsened the equilibrium properties. The threshold for the second stability regime was lowered to β 0 /approximately/ 1.5%. Experimental profile data are compatible with operation in the second stability regime, and the achieved beta values, β 0 /approximately/ 3%, are well beyond the theoretically calculated threshold. Magnetic fluctuation measurements showed the effects of beta self-stabilization. They are in reasonable agreement with the predictions of the theory and support the evidence that ATF has already operated in the second stability regime. 24 refs., 20 figs., 1 tab

  5. Magnetic navigation in a coronary phantom: experimental results.

    Science.gov (United States)

    García-García, Héctor M; Tsuchida, Keiichi; Meulenbrug, Hans; Ong, Andrew T L; Van der Giessen, Willem J; Serruys, Patrick W

    2005-11-01

    The objective was to investigate the efficacy of a magnetic navigation system (MNS) in a coronary phantom. The number of coronary interventional procedures performed is steadily increasing with the availability of new devices to treat more complex lesions. Vessel tortuosity remains an important limiting factor in percutaneous coronary intervention. The MNS can orient the tip of magnetized wire. The coronary phantom is a representation of the coronary tree. Two operators using both a magnetic wire and a standard wire, measured the procedural time (PT), the fluoroscopic time (FT) and the radiation exposure/area product (DAP) required to navigate through to fourteen segments. Ten wire advancements were performed per segment. In all but two segments, the PT was significantly longer using magnetic navigation than using manual navigation. The median FT in the left main artery (LMA) - first septal segment was 7 seconds vs. 18 seconds, with magnetic and manual navigation respectively, (p=0.05); in the LMA - obtuse marginal segment the median FT was 15 seconds with magnetic navigation vs. 29.5 seconds with manual navigation, (p=0.01); in the segment from proximal right coronary artery (RCA1) to the acute marginal branch, the median FT was 8 seconds with magnetic vs. 11 seconds with manual navigation, (p=0.05); and in the RCA1 -posterior descending segment the median FT was 9.5 seconds with magnetic vs. 15 seconds with manual navigation, (p=0.006). The MNS facilitates wire access to distal segments in a coronary phantom, with a reduction in FT and radiation exposure using magnetic navigation in tortuous segments.

  6. Experimental and computational evaluation of area selectively immobilized horseradish peroxidase in a microfluidic device

    DEFF Research Database (Denmark)

    Hoffmann, Christian; Pereira Rosinha Grundtvig, Ines; Thrane, Joachim

    2017-01-01

    experimentally and by computational fluid dynamics (CFD) simulations. Ultimately, such a correlation would lead to faster development through computational pre-screening and optimized experimental design.In this proof-of-concept study, microreactors were prepared in a 2-step curing process of an off......-stoichiometric thiol-ene-epoxy (OSTE+) mixture employing both a thiol-ene (TEC) and a thiol-epoxy curing reaction. Subsequent surface functionalization of the remaining thiol groups on the reactor surface through stenciled photoinitiated TEC enabled the preparation of specific surface patterns in the reactor. Patterns...... as obtained from experimental determination. This good agreement between the obtained experimental and computational results confirmed the high potential of CFD models for predicting and optimizing the biocatalytic performance of such a reactor....

  7. Physiological remodeling of bifurcation aneurysms: preclinical results of the eCLIPs device.

    Science.gov (United States)

    Marotta, Thomas R; Riina, Howard A; McDougall, Ian; Ricci, Donald R; Killer-Oberpfalzer, Monika

    2018-02-01

    OBJECTIVE Intracranial bifurcation aneurysms are complex lesions for which current therapy, including simple coiling, balloon- or stent-assisted coiling, coil retention, or intrasaccular devices, is inadequate. Thromboembolic complications due to a large burden of intraluminal metal, impedance of access to side branches, and a high recurrence rate, due largely to the unmitigated high-pressure flow into the aneurysm (water hammer effect), are among the limitations imposed by current therapy. The authors describe herein a novel device, eCLIPs, and its use in a preclinical laboratory study that suggests the device's design and functional features may overcome many of these limitations. METHODS A preclinical model of wide-necked bifurcation aneurysms in rabbits was used to assess functional features and efficacy of aneurysm occlusion by the eCLIPs device. RESULTS The eCLIPs device, in bridging the aneurysm neck, allows coil retention, disrupts flow away from the aneurysm, leaves the main vessel and side branches unencumbered by intraluminal metal, and serves as a platform for endothelial growth across the neck, excluding the aneurysm from the circulation. CONCLUSIONS The eCLIPs device permits physiological remodeling of the bifurcation.

  8. Effect of the application of an electric field on the performance of a two-phase loop device: preliminary results

    International Nuclear Information System (INIS)

    Creatini, F; Di Marco, P; Filippeschi, S; Fioriti, D; Mameli, M

    2015-01-01

    In the last decade, the continuous development of electronics has pointed out the need for a change in mind with regard to thermal management. In the present scenario, Pulsating Heat Pipes (PHPs) are novel promising two-phase passive heat transport devices that seem to meet all present and future thermal requirements. Nevertheless, PHPs governing phenomena are quite unique and not completely understood. In particular, single closed loop PHPs manifest several drawbacks, mostly related to the reduction of device thermal performance and reliability, i.e. the occurrence of multiple operational quasi-steady states. The present research work proposes the application of an electric field as a technique to promote the circulation of the working fluid in a preferential direction and stabilize the device operation. The tested single closed loop PHP is made of a copper tube with an inner tube diameter equal to 2.00 mm and filled with pure ethanol (60% filling ratio). The electric field is generated by a couple of wire-shaped electrodes powered with DC voltage up to 20 kV and laid parallel to the longitudinal axis of the glass tube constituting the adiabatic section. Although the electric field intensity in the working fluid region is weakened both by the polarization phenomenon of the working fluid and by the interposition of the glass tube, the experimental results highlight the influence of the electric field on the device thermal performance and encourage the continuation of the research in this direction. (paper)

  9. Gold Nanoparticles as Probes for Nano-Raman Spectroscopy: Preliminary Experimental Results and Modeling

    Directory of Open Access Journals (Sweden)

    V. Le Nader

    2012-01-01

    Full Text Available This paper presents an effective Tip-Enhanced Raman Spectrometer (TERS in backscattering reflection configuration. It combines a tip-probe nanopositioning system with Raman spectroscope. Specific tips were processed by anchoring gold nanoparticles on the apex of tapered optical fibers, prepared by an improved chemical etching method. Hence, it is possible to expose a very small area of the sample (~20 nm2 to the very strong local electromagnetic field generated by the lightning rod effect. This experimental configuration was modelled and optimised using the finite element method, which takes into account electromagnetic effects as well as the plasmon resonance. Finally, TERS measurements on single-wall carbon nanotubes were successfully performed. These results confirm the high Raman scattering enhancement predicted by the modelling, induced by our new nano-Raman device.

  10. Calculating buoy response for a wave energy converter—A comparison of two computational methods and experimental results

    Directory of Open Access Journals (Sweden)

    Linnea Sjökvist

    2017-05-01

    Full Text Available When designing a wave power plant, reliable and fast simulation tools are required. Computational fluid dynamics (CFD software provides high accuracy but with a very high computational cost, and in operational, moderate sea states, linear potential flow theories may be sufficient to model the hydrodynamics. In this paper, a model is built in COMSOL Multiphysics to solve for the hydrodynamic parameters of a point-absorbing wave energy device. The results are compared with a linear model where the hydrodynamical parameters are computed using WAMIT, and to experimental results from the Lysekil research site. The agreement with experimental data is good for both numerical models.

  11. Preliminary results on tests of a Cerenkov ring imaging device employing a photoionizing PWC

    Energy Technology Data Exchange (ETDEWEB)

    Durkin, S.; Honma, A.; Leith, D.W.G.S.

    1978-08-01

    A brief description of techniques and problems of ring imaging Cerenkov detectors employing photoionizing PWC's is discussed. Preliminary results on a one dimensional ring imaging device tested at SLAC in May and June of 1978 are then presented. These results include rough measurements of the Cerenkov ring in nitrogen, argon, neon, and helium produced by a collimated positron beam.

  12. Vaporization inside a mini microfin tube: experimental results and modeling

    Science.gov (United States)

    Diani, A.; Rossetto, L.

    2015-11-01

    This paper proposes a comparison among the common R134a and the extremely low GWP refrigerant R1234yf during vaporization inside a mini microfin tube. This microfin tube has an internal diameter of 2.4 mm, it has 40 fins, with a fin height of 0.12 mm. Due to the high heat transfer coefficients shown by this tube, this technology can lead to a refrigerant charge reduction. Tests were run in the Heat Transfer in Micro Geometries Lab of the Dipartimento di Ingegneria Industriale of the Università di Padova. Mass velocities range between 375 and 940 kg m-2 s-1, heat fluxes from 10 to 50 kW m-2, vapour qualities from 0.10 to 0.99, at a saturation temperature of 30°C. The comparison among the two fluids is proposed at the same operating conditions, in order to highlight the heat transfer and pressure drop differences among the two refrigerants. In addition, two correlations are proposed to estimate the heat transfer coefficient and frictional pressure drop during refrigerant flow boiling inside mini microfin tubes. These correlations well predict the experimental values, and thus they can be used as a useful tool to design evaporators based on these mini microfin tubes.

  13. Construction of a WMR for Trajectory Tracking Control: Experimental Results

    Directory of Open Access Journals (Sweden)

    R. Silva-Ortigoza

    2013-01-01

    Full Text Available This paper reports a solution for trajectory tracking control of a differential drive wheeled mobile robot (WMR based on a hierarchical approach. The general design and construction of the WMR are described. The hierarchical controller proposed has two components: a high-level control and a low-level control. The high-level control law is based on an input-output linearization scheme for the robot kinematic model, which provides the desired angular velocity profiles that the WMR has to track in order to achieve the desired position (x*,y* and orientation (φ*. Then, a low-level control law, based on a proportional integral (PI approach, is designed to control the velocity of the WMR wheels to ensure those tracking features. Regarding the trajectories, this paper provides the solution or the following cases: (1 time-varying parametric trajectories such as straight lines and parabolas and (2 smooth curves fitted by cubic splines which are generated by the desired data points x1*,y1*,…,xn*,yn*. A straightforward algorithm is developed for constructing the cubic splines. Finally, this paper includes an experimental validation of the proposed technique by employing a DS1104 dSPACE electronic board along with MATLAB/Simulink software.

  14. Waste glass corrosion modeling: Comparison with experimental results

    International Nuclear Information System (INIS)

    Bourcier, W.L.

    1993-11-01

    A chemical model of glass corrosion will be used to predict the rates of release of radionuclides from borosilicate glass waste forms in high-level waste repositories. The model will be used both to calculate the rate of degradation of the glass, and also to predict the effects of chemical interactions between the glass and repository materials such as spent fuel, canister and container materials, backfill, cements, grouts, and others. Coupling between the degradation processes affecting all these materials is expected. Models for borosilicate glass dissolution must account for the processes of (1) kinetically-controlled network dissolution, (2) precipitation of secondary phases, (3) ion exchange, (4) rate-limiting diffusive transport of silica through a hydrous surface reaction layer, and (5) specific glass surface interactions with dissolved cations and anions. Current long-term corrosion models for borosilicate glass employ a rate equation consistent with transition state theory embodied in a geochemical reaction-path modeling program that calculates aqueous phase speciation and mineral precipitation/dissolution. These models are currently under development. Future experimental and modeling work to better quantify the rate-controlling processes and validate these models are necessary before the models can be used in repository performance assessment calculations

  15. Modeling of rock friction 1. Experimental results and constitutive equations

    International Nuclear Information System (INIS)

    Dieterich, J.H.

    1979-01-01

    Direct shear experiments on ground surfaces of a granodiorite from Raymond, California, at normal stresses of approx.6 MPa demonstrate that competing time, displacement, and velocity, effects control rock friction. It is proposed that the strength of the population of points of contacts between sliding surfaces determines frictional strength and that the population of contacts changes continuously with displacements. Previous experiments demonstrate that the strength of the contacts increases with the age of the contacts. The present experiments establish that a characteristic displacement, proportional to surface roughness, is required to change the population of contacts. Hence during slip the average age of the points of contact and therefore frictional strength decrease as slip velocity increases. Displacement weakening and consequently the potential for unstable slip occur whenever displacement reduces the average age of the contacts. In addition to this velocity dependency, which arises from displacement dependency and time dependency, the experiments also show a competing but transient increase in friction whenever slip velocity increases. Creep of the sliding surface at stresses below that for steady state slip also observed. Constitutive relationships are developed that permit quantitative simulation of the friction versus displacement data as a function of surface roughness and for different time and velocity histories. Unstable slip in experiments is controlled by these constitutive effects and by the stiffness of the experimental system. It is argued that analogous properties control earthquake instability

  16. Experimental results with hydrogen fueled internal combustion engines

    Science.gov (United States)

    De Boer, P. C. T.; Mclean, W. J.; Homan, H. S.

    1975-01-01

    The paper focuses on the most important experimental findings for hydrogen-fueled internal combustion engines, with particular reference to the application of these findings to the assessment of the potential of hydrogen engines. Emphasis is on the various tradeoffs that can be made, such as between maximum efficiency, maximum power, and minimum NO emissions. The various possibilities for induction and ignition are described. Some projections are made about areas in which hydrogen engines may find their initial application and about optimum ways to design such engines. It is shown that hydrogen-fueled reciprocal internal combustion engines offer important advantages with respect to thermal efficiency and exhaust emissions. Problems arising from preignition can suitably be avoided by restricting the fuel-air equivalence ratio to values below about 0.5. The direct cylinder injection appears to be a very attractive way to operate the engine, because it combines a wide range of possible power outputs with a high thermal efficiency and very low NO emissions at part loads.

  17. Experimental Results from a Microwave Cavity Beam Position Monitor

    International Nuclear Information System (INIS)

    Balakin, V.; Bazhan, A.; Lunev, P.; Solyak, N.; Vogel, V.; Zhogolev, P.; Lisitsyn, A.; Yakimenko, V.

    1999-01-01

    Future Linear Colliders have hard requirements for the beam transverse position stability in the accelerator. A beam Position Monitor (BPM) with the resolution better than 0.1 micron in the single bunch regime is needed to control the stability of the beam position along the linac. Proposed BPM is based on the measurement of the asymmetrical mode excited by single bunch in the cavity. Four stages of signal processing (space-, time-, frequency- and phase-filtering providing the required signal-to-noise ratio) are used to obtain extremely high resolution. The measurement set-up was designed by BINP and installed at ATF/BNL to test experimentally this concept. The set-up includes three two-coordinates BPM's at the frequency of 13.566 GHz, and reference intensity/phase cavity. BPM's were mounted on support table. The two-coordinates movers allow to move and align BPM's along the straight line, using the signals from the beam. The position of each monitor is controlled by the sensors with the accuracy 0.03 micron. The information from three monitors allows to exclude angle and position jitter of the beam and measure BPM resolution. In the experiments the resolution of about 0.15 micron for 0.25 nC beam intensity was obtained, that is close to the value required

  18. Innovation in abutment-free bone-anchored hearing devices in children: Updated results and experience.

    Science.gov (United States)

    Baker, Shaun; Centric, Aaron; Chennupati, Sri Kiran

    2015-10-01

    Bone-anchored hearing devices are an accepted treatment option for hearing restoration in various types of hearing loss. Traditional devices have a percutaneous abutment for attachment of the sound processor that contributes to a high complication rate. Previously, our institution reported on the Sophono (Boulder, CO, USA) abutment-free system that produced similar audiologic results to devices with abutments. Recently, Cochlear Americas (Centennial, CO, USA) released an abutment-free bone-anchored hearing device, the BAHA Attract. In contrast to the Sophono implant, the BAHA Attract utilizes an osseointegrated implant. This study aims to demonstrate patient benefit abutment-free devices, compare the results of the two abutment-free devices, and examine complication rates. A retrospective chart review was conducted for the first eleven Sophono implanted patients and for the first six patients implanted with the BAHA Attract at our institution. Subsequently, we analyzed patient demographics, audiometric data, clinical course and outcomes. Average improvement for the BAHA Attract in pure-tone average (PTA) and speech reception threshold (SRT) was 41dB hearing level (dBHL) and 56dBHL, respectively. Considering all frequencies, the BAHA Attract mean improvement was 39dBHL (range 32-45dBHL). The Sophono average improvement in PTA and SRT was 38dBHL and 39dBHL, respectively. The mean improvement with Sophono for all frequencies was 34dBHL (range 24-43dBHL). Significant improvements in both pure-tone averages and speech reception threshold for both devices were achieved. In direct comparison of the two separate devices using the chi-square test, the PTA and SRT data between the two devices do not show a statistically significant difference (p-value 0.68 and 0.56, respectively). The complication rate for these abutment-free devices is lower than that of those featuring the transcutaneous abutment, although more studies are needed to further assess this potential advantage

  19. Data base of reactor physics experimental results in Kyoto University critical assembly experimental facilities

    International Nuclear Information System (INIS)

    Ichihara, Chihiro; Fujine, Shigenori; Hayashi, Masatoshi

    1986-01-01

    The Kyoto University critical assembly experimental facilities belong to the Kyoto University Research Reactor Institute, and are the versatile critical assembly constructed for experimentally studying reactor physics and reactor engineering. The facilities are those for common utilization by universities in whole Japan. During more than ten years since the initial criticality in 1974, various experiments on reactor physics and reactor engineering have been carried out using many experimental facilities such as two solidmoderated cores, a light water-moderated core and a neutron generator. The kinds of the experiment carried out were diverse, and to find out the required data from them is very troublesome, accordingly it has become necessary to make a data base which can be processed by a computer with the data accumulated during the past more than ten years. The outline of the data base, the data base CAEX using personal computers, the data base supported by a large computer and so on are reported. (Kako, I.)

  20. Structural analysis and manufacture for the vacuum vessel of experimental advanced superconducting tokamak (EAST) device

    International Nuclear Information System (INIS)

    Song Yuntao; Yao Damao; Wu Songata; Weng Peide

    2006-01-01

    The experimental advanced superconducting tokamak (EAST) is an advanced steady-state plasma physics experimental device, which has been approved by the Chinese government and is being constructed as the Chinese national nuclear fusion research project. The vacuum vessel, that is one of the key components, will have to withstand not only the electromagnetic force due to the plasma disruption and the Halo current, but also the pressure of boride water and the thermal stress due to the 250 deg. C baking out by the hot pressure nitrogen gas, or the 100 deg. C hot wall during plasma operation. This paper is a report of the mechanical analyses of the vacuum vessel. According to the allowable stress criteria of American Society of Mechanical Engineers, Boiler and Pressure Vessel Committee (ASME), the maximum integrated stress intensity on the vacuum vessel is 396 MPa, less than the allowable design stress intensity 3S m (441 MPa). At the same time, some key R and D issues are presented, which include supporting system, bellows and the assembly of the whole vacuum vessel

  1. Experimental device for investigating the crack growth behaviour of RPV steel under BWR conditions

    International Nuclear Information System (INIS)

    Anders, D.; Ahlf, J.

    1983-01-01

    An experimental device is developed to investigate the crack growth behaviour of RPV steel specimens under service conditions. It will be installed in the experimental power station VAK-Kahl (BWR, 16 MWe). The in pile part is composed of a stable frame with a hydraulically actuated load mechanism, the specimen chain and a measuring instrumentation. The specimen chain, fastened between load mechanism and a lower fixing point at the frame, is made up of five compact tensile specimens (CT40) and the associated connecting links. Specimen strain, crack opening and temperature are measured; for neutron dose monitoring activation wires are disposed. Out of pile, in the reactor hall, the hydraulic loading system is installed. The loading force is generated by a 100 kN-material testing machine; it moves a piston in the control cylinder, which is connected to the loading bellows of the in pile section. The measuring and control equipment and a desk computer serving for data preparation and reduction is placed in the reactor control room. (Auth.)

  2. A review of experimental results at the knee

    International Nuclear Information System (INIS)

    Hoeorandel, Joerg R.

    2006-01-01

    Results of experiments investigating air showers in the energy region of the knee are summarized. The all-particle energy spectrum, the mean logarithmic mass, and the average depth of the shower maximum will be discussed. Spectra for groups of elements from air shower data are compared to results from direct measurements

  3. Experimental results on charmonium from E760 (FNAL)

    International Nuclear Information System (INIS)

    Armstrong, T.A.; Hasan, M.A.; Lewis, R.A.; Majewska, A.M.; Reid, J.D.; Smith, G.A.; Zhang, Y.; Bettoni, D.; Borreani, G.; Calabrese, R.; Dalpiaz, P.; Dalpiaz, P.F.; Fabbri, M.; Luppi, E.; Martini, M.; Petrucci, F.; Savrie, M.; Bharadwaj, V.; Church, M.D.; Hahn, A.A.; Hsueh, S.Y.; Marsh, W.; Peoples, J. Jr.; Pordes, S.; Rapidis, P.A.; Werkema, S.J.; Biino, C.; Ceccucci, A.; Cester, R.; Marchetto, F.; Menichetti, E.; Migliori, A.; Mussa, R.; Palestini, S.; Pastrone, N.; Pesando, L.; Rinaudo, G.; Tecchio, L.; Broemmelsiek, D.R.; Fast, J.E.; Gee, M.; Gollwitzer, K.E.; Mandelkern, M.A.; Marques, J.L.; Schultz, J.; Weber, M.F.; Zioulas, G.; Buzzo, A.; Dameri, M.; Ferroni, S.; Macri, M.; Marinelli, M.; Patrignani, C.; Pia, M.G.; Santroni, A.; Tommasini, S.; Zito, M.; Dimitroyannis, D.; Ginsburg, C.M.; Masuzawa, M.; Rosen, J.L.; Sarmiento, M.; Seth, K.K.; Trokenheim, S.; Zhao, J.L.; Ray, R.E.

    1992-01-01

    E760 is a fixed target experiment dedicated to the study of charmonium spectroscopy in anti pp annihilations. Results on X 1 and X 2 resonance parameters from 1990 data taking are presented, consisting of precise measurement of mass, total width and partial width to anti pp. A preliminary result is presented on the first determination of Ψ'width from line shape analysis. (orig.)

  4. Physiological responses of adult rainbow trout experimentally released through a unique fish conveyance device

    Science.gov (United States)

    Mesa, Matthew G.; Gee, Lisa P.; Weiland, Lisa K.; Christiansen, Helena E.

    2013-01-01

    We assessed the physiological stress responses (i.e., plasma levels of cortisol, glucose, and lactate) of adult Rainbow Trout Oncorhynchus mykiss at selected time intervals after they had passed a distance of 15 m through a unique fish conveyance device (treatment fish) or not (controls). This device differs from traditional fish pumps in two important ways: (1) it transports objects in air, rather than pumping them from and with water; and (2) it uses a unique tube for transport that has a series of soft, deformable baffles spaced evenly apart and situated perpendicular within a rigid, but flexible outer shell. Mean concentrations of the plasma constituents never differed (P > 0.05) between control and treatment fish at 0, 1, 4, 8, or 24 h after passage, and only minor differences were apparent between the different time intervals within a group. We observed no obvious injuries on any of our fish. Our results indicate that passage through this device did not severely stress or injure fish and it may allow for the rapid and safe movement of fish at hatcheries, sorting or handling facilities, or passage obstacles.

  5. New experimental results on electron cooling at COSY-Juelich

    International Nuclear Information System (INIS)

    Dietrich, J.; Maier, R.; Prasuhn, D.; Stein, H.J.; Kobets, A.; Meshkov, I.; Sidorin, A.; Smirnov, A.

    2007-01-01

    Recent results of electron cooling of proton beams at COSY-Juelich are reported. Cooling at an electron energy of 70 keV has been studied for the first time. At the injection energy level of COSY, corresponding to 24.5 keV electron energy, the features of the cooled proton beam at extremely low intensities have been investigated in order to find out whether an ordering of the proton beam can be achieved. Such investigations are motivated by the results of a numerical simulation of the ordering process by the BETACOOL code. (author)

  6. Comments on experimental results of energy confinement of tokamak plasmas

    International Nuclear Information System (INIS)

    Chu, T.K.

    1989-04-01

    The results of energy-confinement experiments on steady-state tokamak plasmas are examined. For plasmas with auxiliary heating, an analysis based on the heat diffusion equation is used to define heat confinement time (the incremental energy confinement time). For ohmically sustained plasmas, experiments show that the onset of the saturation regime of energy confinement, marfeing, detachment, and disruption are marked by distinct values of the parameter /bar n//sub e///bar j/. The confinement results of the two types of experiments can be described by a single surface in 3-dimensional space spanned by the plasma energy, the heating power, and the plasma density: the incremental energy confinement time /tau//sub inc/ = ΔW/ΔP is the correct concept for describing results of heat confinement in a heating experiment; the commonly used energy confinement time defined by /tau//sub E/ = W/P is not. A further examination shows that the change of edge parameters, as characterized by the change of the effective collision frequency ν/sub e/*, governs the change of confinement properties. The totality of the results of tokamak experiments on energy confinement appears to support a hypothesis that energy transport is determined by the preservation of the pressure gradient scale length. 70 refs., 6 figs., 1 tab

  7. Modeling and Experimental Tests of a Mechatronic Device to Measure Road Profiles Considering Impact Dynamics

    DEFF Research Database (Denmark)

    Souza, A.; Santos, Ilmar

    2002-01-01

    dynamics is led with help of a set of non-linear equations of motion obtained using Newton-Euler-Jourdain´s Method. Such a set of equation is numerically solved and the theoretical results are compared with experimental carried out with a laboratory prototype. Comparisons show that the theoretical model...... predicts well the mechanism movements. However it was also experimentally observed that the contact between the wheels and the road profile is not permanent. To analyze the non-contact between the wheels and the road, the Newton-Euler´s Method is used to calculate forces and moments of reactions between...

  8. Experimental high power plasma-filled backward wave oscillator results

    International Nuclear Information System (INIS)

    Minami, K.; Lou, W.R.; Destler, W.W.; Kehs, R.A.; Granatstein, V.L.; Carmel, Y.

    1988-01-01

    Previous results have indicated that a background gas can be used to increase the output microwave power of relativistic backward wave oscillators (BWOs) two or three times the vacuum case. In their experiments, two methods of plasma production are investigated in detail: the use of the electron beam to ionize a background gas, and the use of a plasma gun to inject a background plasma into the slow-wave structure of a BWO. It is found in the first case that there was a resonant increase in microwave power at a particular pressure of the background gas by a factor of ten. In the second case, power also increased compared with power production in vacuum. Detailed results are presented and the relative merits of the two approaches is discussed and compared with theoretical expectations

  9. Verification of aseismic design model by using experimental results

    International Nuclear Information System (INIS)

    Mizuno, N.; Sugiyama, N.; Suzuki, T.; Shibata, Y.; Miura, K.; Miyagawa, N.

    1985-01-01

    A lattice model is applied as an analysis model for an aseismic design of the Hamaoka nuclear reactor building. With object to verify an availability of this design model, two reinforced concrete blocks are constructed on the ground and the forced vibration tests are carried out. The test results are well followed by simulation analysis using the lattice model. Damping value of the ground obtained from the test is more conservative than the design value. (orig.)

  10. Calculation results and experimental testing of doppler feedback coefficients

    International Nuclear Information System (INIS)

    Yang Shunhai

    1989-01-01

    The Doppler feedback coefficients are calculated by the interpolation and group collapsing method from multigroup self-shielding factors and infinite dilution cross sections rather than effective resonance integrals by using resonance data base. Since many updated sets of multigroup data are in existence to be selected, the calculation process can be simplified. The heterogeneous effects are taken into account by equivalence relation. The computer code of Doppler feedback coefficients is created on computer CYBER-825 and PDP-11. The results calculated are in good agreement with the experiments

  11. Experimental test accelerator: description and results of initial experiments

    International Nuclear Information System (INIS)

    Fessenden, T.; Birx, D.; Briggs, R.

    1980-01-01

    The ETA is a high current (10,000 Amp) linear induction accelerator that produces short (30 ns) pulses of electrons at 5 MeV twice per second or in bursts of 5 pulses separated by as little as one millisecond. At this time the machine has operated at 65% of its design current and 90% of the design voltage. This report contains a description of the accelerator and its diagnostics; the results of the initial year of operation; a comparison of design codes with experiments on beam transport; and a discussion of some of the special problems and their status

  12. Experimental investigation of vapor shielding effects induced by ELM-like pulsed plasma loads using the double plasma gun device

    Science.gov (United States)

    Sakuma, I.; Kikuchi, Y.; Kitagawa, Y.; Asai, Y.; Onishi, K.; Fukumoto, N.; Nagata, M.

    2015-08-01

    We have developed a unique experimental device of so-called double plasma gun, which consists of two magnetized coaxial plasma gun (MCPG) devices, in order to clarify effects of vapor shielding on material erosion due to transient events in magnetically confined fusion devices. Two ELM-like pulsed plasmas produced by the two MCPG devices were injected into a target chamber with a variable time difference. For generating ablated plasmas in front of a target material, an aluminum foil sample in the target chamber was exposed to a pulsed plasma produced by the 1st MCPG device. The 2nd pulsed plasma was produced with a time delay of 70 μs. It was found that a surface absorbed energy measured by a calorimeter was reduced to ∼66% of that without the Al foil sample. Thus, the reduction of the incoming plasma energy by the vapor shielding effect was successfully demonstrated in the present experiment.

  13. Experimental investigation of vapor shielding effects induced by ELM-like pulsed plasma loads using the double plasma gun device

    Energy Technology Data Exchange (ETDEWEB)

    Sakuma, I., E-mail: eu13z002@steng.u-hyogo.ac.jp; Kikuchi, Y.; Kitagawa, Y.; Asai, Y.; Onishi, K.; Fukumoto, N.; Nagata, M.

    2015-08-15

    We have developed a unique experimental device of so-called double plasma gun, which consists of two magnetized coaxial plasma gun (MCPG) devices, in order to clarify effects of vapor shielding on material erosion due to transient events in magnetically confined fusion devices. Two ELM-like pulsed plasmas produced by the two MCPG devices were injected into a target chamber with a variable time difference. For generating ablated plasmas in front of a target material, an aluminum foil sample in the target chamber was exposed to a pulsed plasma produced by the 1st MCPG device. The 2nd pulsed plasma was produced with a time delay of 70 μs. It was found that a surface absorbed energy measured by a calorimeter was reduced to ∼66% of that without the Al foil sample. Thus, the reduction of the incoming plasma energy by the vapor shielding effect was successfully demonstrated in the present experiment.

  14. Space Launch System Base Heating Test: Experimental Operations & Results

    Science.gov (United States)

    Dufrene, Aaron; Mehta, Manish; MacLean, Matthew; Seaford, Mark; Holden, Michael

    2016-01-01

    NASA's Space Launch System (SLS) uses four clustered liquid rocket engines along with two solid rocket boosters. The interaction between all six rocket exhaust plumes will produce a complex and severe thermal environment in the base of the vehicle. This work focuses on a recent 2% scale, hot-fire SLS base heating test. These base heating tests are short-duration tests executed with chamber pressures near the full-scale values with gaseous hydrogen/oxygen engines and RSRMV analogous solid propellant motors. The LENS II shock tunnel/Ludwieg tube tunnel was used at or near flight duplicated conditions up to Mach 5. Model development was based on the Space Shuttle base heating tests with several improvements including doubling of the maximum chamber pressures and duplication of freestream conditions. Test methodology and conditions are presented, and base heating results from 76 runs are reported in non-dimensional form. Regions of high heating are identified and comparisons of various configuration and conditions are highlighted. Base pressure and radiometer results are also reported.

  15. Impacts of changing hydrology on permanent gully growth: experimental results

    Science.gov (United States)

    Day, Stephanie S.; Gran, Karen B.; Paola, Chris

    2018-06-01

    Permanent gullies grow through head cut propagation in response to overland flow coupled with incision and widening in the channel bottom leading to hillslope failures. Altered hydrology can impact the rate at which permanent gullies grow by changing head cut propagation, channel incision, and channel widening rates. Using a set of small physical experiments, we tested how changing overland flow rates and flow volumes alter the total volume of erosion and resulting gully morphology. Permanent gullies were modeled as both detachment-limited and transport-limited systems, using two different substrates with varying cohesion. In both cases, the erosion rate varied linearly with water discharge, such that the volume of sediment eroded was a function not of flow rate, but of total water volume. This implies that efforts to reduce peak flow rates alone without addressing flow volumes entering gully systems may not reduce erosion. The documented response in these experiments is not typical when compared to larger preexisting channels where higher flow rates result in greater erosion through nonlinear relationships between water discharge and sediment discharge. Permanent gullies do not respond like preexisting channels because channel slope remains a free parameter and can adjust relatively quickly in response to changing flows.

  16. An experimental study of the flow characteristics of fluidic device in a passive safety injection tank

    International Nuclear Information System (INIS)

    Cho, Seok; Song, Chul Hwa; Won, Suon Yeon; Min, Kyong Ho; Chung, Moon Ki

    1998-01-01

    It is considered to adopt passive safety injection tank (SIT) as a enhanced safety feature in KNGR. Passive SIT employs a vortex chamber as a fluidic device, which control injection flow rate passively by the variation of flow resistance produced by vortex intensity within the vortex chamber. To investigate the flow characteristics of the vortex chamber many tests have been carried out by using small-scale test facility. In this report the effects of geometric parameters of vortex chamber on discharge flow characteristics and the velocity measurement result of flow field, measured by PIV, are presented and discussed. (author). 25 refs., 11 tabs., 31 figs

  17. A novel device for grasping assessment during functional tasks: preliminary results

    Directory of Open Access Journals (Sweden)

    Ana Carolinne Portela Rocha

    2016-02-01

    Full Text Available This paper presents a methodology and first results obtained in a study with a novel device that allows the analysis of grasping quality. Such a device is able to acquire motion information of upper limbs allowing kinetic of manipulation analysis as well. A pilot experiment was carried out with six groups of typically developing children aged between 5 and 10 years old, with 7-8 children in each one. The device, designed to emulate a glass, has an optical system composed by one digital camera and a special convex mirror that together allow image acquisition of grasping hand posture when it is grasped and manipulated. It also carries an Inertial Measurement Unit (IMU that captures motion data as acceleration, orientation, and angular velocities. The novel instrumented object is used in our approach to evaluate functional tasks performance in quantitative terms. During tests each child was invited to grasp the cylindrical part of the device that was placed on the top of a table, simulating the task of drinking a glass of water. In the sequence the child was oriented to transport the device back to the starting position and release it. The task was repeated 3 times for each child. A grasping hand posture evaluation is presented as an example to evaluate grasping quality. Additionally, motion patterns obtained with the triasl performed with the different groups are presented and discussed. This device is attractive due to its portable characteristics, the small size and its ability to evaluate grasping form. The results may be also useful to analyze the evolution of the rehabilitation process through reach-to-grasping movement and the grasping images analysis.

  18. Analytical procedure for experimental quantification of carrier concentration in semiconductor devices by using electric scanning probe microscopy

    International Nuclear Information System (INIS)

    Fujita, Takaya; Matsumura, Koji; Itoh, Hiroshi; Fujita, Daisuke

    2014-01-01

    Scanning capacitance microscopy (SCM) is based on a contact-mode variant of atomic force microscopy, which is used for imaging two-dimensional carrier (electrons and holes) distributions in semiconductor devices. We introduced a method of quantification of the carrier concentration by experimentally deduced calibration curves, which were prepared for semiconductor materials such as silicon and silicon carbide. The analytical procedure was circulated to research organizations in a round-robin test. The effectiveness of the method was confirmed for practical analysis and for what is expected for industrial pre-standardization from the viewpoint of comparability among users. It was also applied to other electric scanning probe microscopy techniques such as scanning spreading resistance microscopy and scanning nonlinear dielectric microscopy. Their depth profiles of carrier concentration were found to be in good agreement with those characterized by SCM. These results suggest that our proposed method will be compatible with future next-generation microscopy. (paper)

  19. Experimental results on low alpha electron-storage rings

    International Nuclear Information System (INIS)

    Robin, D.; Hama, H.; Nadji, A.

    1995-09-01

    The authors report on experiments performed in two synchrotron light sources, UVSOR and Super-ACO, where the momentum compaction factor is reduced in order to reduce the bunch length. By controlling the second-order momentum compaction factor, UVSOR and Super-ACO have managed to reduce the first-order momentum compaction factor by 100. At low current the resulting bunch lengths are less than 10 ps, a factor of 10 smaller than normal. Measurements of current dependent bunch lengthening in UVSOR are presented and the cause of the bunch lengthening is determined to be potential-well distortion. The authors also show that by operating with a negative momentum compaction factor, SuperACO has achieved shorter bunch lengthening and higher peak currents than at positive momentum compaction

  20. New experimental results in atlas-based brain morphometry

    Science.gov (United States)

    Gee, James C.; Fabella, Brian A.; Fernandes, Siddharth E.; Turetsky, Bruce I.; Gur, Ruben C.; Gur, Raquel E.

    1999-05-01

    In a previous meeting, we described a computational approach to MRI morphometry, in which a spatial warp mapping a reference or atlas image into anatomic alignment with the subject is first inferred. Shape differences with respect to the atlas are then studied by calculating the pointwise Jacobian determinant for the warp, which provides a measure of the change in differential volume about a point in the reference as it transforms to its corresponding position in the subject. In this paper, the method is used to analyze sex differences in the shape and size of the corpus callosum in an ongoing study of a large population of normal controls. The preliminary results of the current analysis support findings in the literature that have observed the splenium to be larger in females than in males.

  1. Experimental results: Pilot plant calcine dissolution and liquid feed stability

    International Nuclear Information System (INIS)

    Herbst, R.S.; Fryer, D.S.; Brewer, K.N.; Johnson, C.K.; Todd, T.A.

    1995-02-01

    The dissolution of simulated Idaho Chemical Processing Plant pilot plant calcines, containing none of the radioactive actinides, lanthanides or fission products, was examined to evaluate the solubility of calcine matrix materials in acidic media. This study was a necessary precursor to dissolution and optimization experiments with actual radionuclide-containing calcines. The importance of temperature, nitric acid concentration, ratio of acid volume to calcine mass, and time on the amount, as a weight percentage of calcine dissolved, was evaluated. These parameters were studied for several representative pilot plant calcine types: (1) Run No. 74 Zirconia calcine; (2) Run No. 17 Zirconia/Sodium calcine; (3) Run No. 64 Zirconia/Sodium calcine; (3) Run No. 1027 Alumina calcine; and (4) Run No. 20 Alumina/Zirconia/Sodium calcine. Statistically designed experiments with the different pilot plant calcines indicated the effect of the studied process variables on the amount of calcine dissolved decreases in the order: Acid/Calcine Ratio > Temperature > HNO 3 Concentration > Dissolution Time. The following conditions are suitable to achieve greater than 90 wt. % dissolution of most Zr, Al, or Na blend calcines: (1) Maximum nitric acid concentration of 5M; (2) Minimum acid/calcine ratio of 10 mL acid/1 gram calcine; (3) Minimum dissolution temperature of 90 degrees C; and (4) Minimum dissolution time of 30 minutes. The formation of calcium sulphate (CaSO 4 ) precipitates was observed in certain dissolved calcine solutions during the dissolution experiments. Consequently, a study was initiated to evaluate if and under what conditions the resulting dissolved calcine solutions would be unstable with regards to precipitate formation. The results indicate that precipitate formation in the calcine solutions prepared under the above proposed dissolution conditions are not anticipated

  2. Integrating the results of user research into medical device development: insights from a case study

    Directory of Open Access Journals (Sweden)

    Martin Jennifer L

    2012-07-01

    Full Text Available Abstract Background It is well established that considering users is an important aspect of medical device development. However it is also well established that there are numerous barriers to successfully conducting user research and integrating the results into product development. It is not sufficient to simply conduct user research, it must also be effectively integrated into product development. Methods A case study of the development of a new medical imaging device was conducted to examine in detail how users were involved in a medical device development project. Two user research studies were conducted: a requirements elicitation interview study and an early prototype evaluation using contextual inquiry. A descriptive in situ approach was taken to investigate how these studies contributed to the product development process and how the results of this work influenced the development of the technology. Data was collected qualitatively through interviews with the development team, participant observation at development meetings and document analysis. The focus was on investigating the barriers that exist to prevent user data from being integrated into product development. Results A number of individual, organisational and system barriers were identified that functioned to prevent the results of the user research being fully integrated into development. The user and technological aspects of development were seen as separate work streams during development. The expectations of the developers were that user research would collect requirements for the appearance of the device, rather than challenge its fundamental concept. The manner that the user data was communicated to the development team was not effective in conveying the significance or breadth of the findings. Conclusion There are a range of informal and formal organisational processes that can affect the uptake of user data during medical device development. Adopting formal decision

  3. Experimental Results of Integrated Refrigeration and Storage System Testing

    Science.gov (United States)

    Notardonato, W. U.; Johnson, W. L.; Jumper, K.

    2009-01-01

    Launch operations engineers at the Kennedy Space Center have identified an Integrated Refrigeration and Storage system as a promising technology to reduce launch costs and enable advanced cryogenic operations. This system uses a close cycle Brayton refrigerator to remove energy from the stored cryogenic propellant. This allows for the potential of a zero loss storage and transfer system, as well and control of the state of the propellant through densification or re-liquefaction. However, the behavior of the fluid in this type of system is different than typical cryogenic behavior, and there will be a learning curve associated with its use. A 400 liter research cryostat has been designed, fabricated and delivered to KSC to test the thermo fluid behavior of liquid oxygen as energy is removed from the cryogen by a simulated DC cycle cryocooler. Results of the initial testing phase focusing on heat exchanger characterization and zero loss storage operations using liquid oxygen are presented in this paper. Future plans for testing of oxygen densification tests and oxygen liquefaction tests will also be discussed. KEYWORDS: Liquid Oxygen, Refrigeration, Storage

  4. Bridge Testing With Ground-Based Interferometric Radar: Experimental Results

    International Nuclear Information System (INIS)

    Chiara, P.; Morelli, A.

    2010-01-01

    The research of innovative non-contact techniques aimed at the vibration measurement of civil engineering structures (also for damage detection and structural health monitoring) is continuously directed to the optimization of measures and methods. Ground-Based Radar Interferometry (GBRI) represents the more recent technique available for static and dynamic control of structures and ground movements.Dynamic testing of bridges and buildings in operational conditions are currently performed: (a) to assess the conformity of the structure to the project design at the end of construction; (b) to identify the modal parameters (i.e. natural frequencies, mode shapes and damping ratios) and to check the variation of any modal parameters over the years; (c) to evaluate the amplitude of the structural response to special load conditions (i.e. strong winds, earthquakes, heavy railway or roadway loads). If such tests are carried out by using a non-contact technique (like GBRI), the classical issues of contact sensors (like accelerometers) are easily overtaken.This paper presents and discusses the results of various tests carried out on full-scale bridges by using a Stepped Frequency-Continuous Wave radar system.

  5. Bridge Testing With Ground-Based Interferometric Radar: Experimental Results

    Science.gov (United States)

    Chiara, P.; Morelli, A.

    2010-05-01

    The research of innovative non-contact techniques aimed at the vibration measurement of civil engineering structures (also for damage detection and structural health monitoring) is continuously directed to the optimization of measures and methods. Ground-Based Radar Interferometry (GBRI) represents the more recent technique available for static and dynamic control of structures and ground movements. Dynamic testing of bridges and buildings in operational conditions are currently performed: (a) to assess the conformity of the structure to the project design at the end of construction; (b) to identify the modal parameters (i.e. natural frequencies, mode shapes and damping ratios) and to check the variation of any modal parameters over the years; (c) to evaluate the amplitude of the structural response to special load conditions (i.e. strong winds, earthquakes, heavy railway or roadway loads). If such tests are carried out by using a non-contact technique (like GBRI), the classical issues of contact sensors (like accelerometers) are easily overtaken. This paper presents and discusses the results of various tests carried out on full-scale bridges by using a Stepped Frequency-Continuous Wave radar system.

  6. Recent experimental results on solutions of deuterium in lithium

    International Nuclear Information System (INIS)

    Ihle, H.R.; Wu, C.H.

    1976-01-01

    The existence of a number of stable molecules containing lithium and hydrogen isotopes in the saturated vapor over dilute solutions of hydrogen isotopes in lithium causes an unexpectedly high density of hydrogen isotopes in the vapor at high temperature. An evaluation of the partial pressures of the gas species Li, Li 2 , LiD, Li 2 D, LiD 2 and D 2 over solutions of deuterium in lithium measured in the temperature range 770 to 970 0 K, and extrapolation to higher temperatures, leads to the conclusion that the ratio of the atom fraction of deuterium in the gas to its atom fraction in the liquid exceeds unity above approximately 1240 0 K; this ratio is independent of the deuterium atom fraction in the liquid at low concentrations. Therefore the thermodynamic supposition that hydrogen isotopes can be separated from lithium by fractional distillation even at extremely low concentration exists. A direct verification of this phenomenon was made by Rayleigh distillation of Li-D solutions in the temperature range 970 to 1600 0 K. These measurements yield also the ratio of the deuterium atom fraction in the gas to that in the liquid and are in good agreement with the data obtained by extrapolation of partial pressures. The enrichment and depletion of deuterium in dependence on the number of theoretical plates of a distillation column at total reflux is calculated using the results

  7. Experimentally increasing sedentary behavior results in decreased life satisfaction

    Directory of Open Access Journals (Sweden)

    Meghan K. Edwards

    2017-03-01

    behavior-inducing randomized controlled intervention on life satisfaction. Methods: Active, young adults between the ages of 18-35 were recruited and randomly assigned into a sedentary behavior intervention group (n = 26 or a control group (n = 13. The intervention group participants were instructed to eliminate all exercise and restrict daily steps (as measured via pedometry to 5000 or less per day for one week. The control group was instructed to maintain regular levels of exercise and other physical activity for one week. Both groups completed the Satisfaction with Life Scale (SWLS pre-intervention and immediately post-intervention. Results: There was a significant group x time interaction (F = 32.75, P < 0.001, with post-hoc contrast tests indicating decreased SWLS score (indicating lower levels of life satisfaction in the intervention group during Visit 2 (post-intervention compared with Visit 1 (pre-intervention; this corresponded with a mean absolute (Visit 2 minus Visit 1 change of -8.58 (95% CI: -5.91, -11.24 for SWLS scores in the intervention group (31.1% reduction. Conclusion: A one-week sedentary behavior-inducing intervention may negatively impact life satisfaction in an active, young adult population. Regular physical activity may be imperative in avoiding negative life satisfaction-related consequences.

  8. The experimental results and analysis of a borehole radar prototype

    International Nuclear Information System (INIS)

    Liu, Sixin; Wu, Junjun; Dong, Hang; Fu, Lei; Wang, Fei

    2012-01-01

    A prototype of borehole radar has been successfully tested in three sites for different purposes under a field condition. The objective of the prototype is providing an effective down-hole tool for detecting targets in deep boreholes situated in a relatively high conductivity area such as the metal ores. The first testing site is at a geothermal field. The fractures extending more than 20 m from the borehole are delineated by the borehole radar in the single-hole reflection mode. The second testing site is located in a jade mine for basement evaluation. The cross-hole measurement mode was used to detect the cavities made by previous unorganized mining activities. Several high-velocity anomalies were found in the velocity profile and presumably the targets of the mine shafts and tunnels. The third test site is located in a mineralized belt characterized by low resistivity less than 1000 Ohm m, the surface-borehole measurement was carried out and the data were processed with velocity tomography. The low-velocity zone corresponds to a mineralized zone from geological records. The three testing results proved the readiness of this borehole radar prototype for further deployment in more complicated and realistic field situations. (paper)

  9. First experimental results on the IShTAR testbed

    Energy Technology Data Exchange (ETDEWEB)

    D’Inca, R.; Jacquot, J.; Ochoukov, R.; Morgal, I.; Fünfgelder, H.; Faugel, H. [Max-Planck-Institut für Plasmaphysik, Garching (Germany); Crombe, K.; Louche, F.; Van Eester, D. [LPP-ERM-KMS, TEC partner, Brussels (Belgium); Heuraux, S.; Devaux, S.; Moritz, J.; Faudot, E. [Institut Jean Lamour UMR 7198 CNRS-Université de Lorraine, Nancy (France); Noterdaeme, J.-M. [Max-Planck-Institut für Plasmaphysik, Garching (Germany); Department of Applied Physics, Ghent University (Belgium)

    2015-12-10

    IShTAR (Ion cyclotron Sheath Test ARrangement) is a linear magnetized plasma test facility dedicated to the investigation of RF wave/plasma interaction [1] in the Ion Cyclotron Range of Frequencies (ICRF). It provides a better accessibility for the instrumentation than tokamaks while being representative of the neighboring region of the wave emitter. It is equipped with a magnetized plasma source (1 m long, 0.4 m diameter) powered by a helical antenna up to 3 kW at 11 MHz. We present the results of the first analysis of the plasma characteristics (plasma density, electron temperature) in function of the operating parameters (injected power, neutral pressure and magnetic field) as measured with fixed and movable Langmuir probes, spectrometer and cameras. The plasma is presently produced only by the helical antenna (no ICRF). We show that the plasma exists in three regime depending on the power level: the first two ones are stable and separated by a jump in density; a first spatial profile of the plasma density has been established for these modes; The third mode is unstable, characterized by strong oscillations of the plasma tube position.

  10. Equatorial spread F: a review of recent experimental results

    International Nuclear Information System (INIS)

    Kelley, M.C.

    1979-01-01

    In this paper the authors review an intense research effort aimed at understanding the large scale disruption of the equatorial F layer which often commences just after sunset, and lasts for most of the night. A very attractive explanation for the phenomena, although one not universally accepted, is that the F layer is unstable to the classic Rayleigh-Taylor condition in which a heavy fluid, the plasma, is supported against gravity by a light 'fluid', the Earth's magnetic field. It is concluded that a reasonable case has been made for this explanation provided that the concept is extended to include nonlinear Rayleigh-Taylor like buoyancy effects above the F peak where linear process is stable. Internal gravity waves in neutral atmosphere seem to play an important role in seeding the Rayleigh-Taylor process with large scale finite amplitude perturbations. One of the remarkable features of this phenomena is the nearly simultaneous generation of structure with scale sizes spanning five orders of magnitude. These results may have applications in astrophysical processes where the Rayleigh-Taylor instability is thought to play a role. (Auth.)

  11. The European Tracer Experiment - experimental results and database

    International Nuclear Information System (INIS)

    Nodop, K.; Connolly, R.; Girardi, F.

    1997-01-01

    As part of the European Tracer Experiment (ETEX) two successful atmospheric experiments were carried out in October and November, 1994. Perfluorocarbon (PFC) tracers were released into the atmosphere in Monterfil, Brittany, and air samples were taken at 168 stations in 17 European countries for 72 hours after the release. Upper air tracer measurements were made from three aircraft. During the first experiment a westerly air flow transported the tracer plume north-eastwards across Europe. During the second release the flow was eastwards. The results from the ground sampling network allowed the determination of the cloud evolution as far as Sweden, Poland and Bulgaria. Typical background concentrations of the tracer used are around 5 to 7 fl/l in ambient air. Concentrations in the plume ranged from 10 to above 200 fl/l. The tracer release characteristics, the tracer concentrations at the ground and in upper air, the routine and additional meteorological observations at the ground level and in upper air, trajectories derived from constant-level balloons and the meteorological input fields for long-range transport (LRT) models are assembled in the ETEX database. The ETEX database is accessible via the Internet

  12. EXPERIMENTAL RESULTS OF THE NEPHELINE PHASE III STUDY

    Energy Technology Data Exchange (ETDEWEB)

    Fox, K.; Edwards, T.

    2009-11-09

    This study is the third phase in a series of experiments designed to reduce conservatism in the model that predicts the formation of nepheline, a crystalline phase that can reduce the durability of high level waste glass. A Phase I study developed a series of glass compositions that were very durable while their nepheline discriminator values were well below the current nepheline discriminator limit of 0.62, where nepheline is predicted to crystallize upon slow cooling. A Phase II study selected glass compositions to identify any linear effects of composition on nepheline crystallization and that were restricted to regions that fell within the validation ranges of the Defense Waste Processing Facility (DWPF) Product Composition Control System (PCCS) models. However, it was not possible to identify any linear effects of composition on chemical durability performance for this set of study glasses. The results of the Phase II study alone were not sufficient to recommend modification of the current nepheline discriminator. It was recommended that the next series of experiments continue to focus not only on compositional regions where the PCCS models are considered applicable (i.e., the model validation ranges), but also be restricted to compositional regions where the only constraint limiting processing is the current nepheline discriminator. Two methods were used in selecting glasses for this Phase III nepheline study. The first was based on the relationship of the current nepheline discriminator model to the other DWPF PCCS models, and the second was based on theory of crystallization in mineral and glass melts. A series of 29 test glass compositions was selected for this study using a combination of the two approaches. The glasses were fabricated and characterized in the laboratory. After reviewing the data, the study glasses generally met the target compositions with little issue. Product Consistency Test results correlated well with the crystallization analyses in

  13. OPERA and MINOS Experimental Result Prove Big Bang Theory Invalid

    Science.gov (United States)

    Pressler, David E.

    2012-03-01

    The greatest error in the history of science is the misinterpretation of the Michelson-Morley Experiment. The speed of light was measured to travel at the same speed in all three directions (x, y, z axis) in ones own inertial reference system; however, c will always be measured as having an absolute different speed in all other inertial frames at different energy levels. Time slows down due to motion or a gravity field. Time is the rate of physical process. Speed = Distance/Time. If the time changes the distance must change. Therefore, BOTH mirrors must move towards the center of the interferometer and space must contract in all-three-directions; C-Space. Gravity is a C-Space condition, and is the cause of redshift in our universe-not motion. The universe is not expanding. OPERA results are directly indicated; at the surface of earth, the strength of the gravity field is at maximum-below the earth's surface, time and space is less distorted, C-Space; therefore, c is faster. Newtonian mechanics dictate that a spherical shell of matter at greater radii, with uniform density, produces no net force on an observer located centrally. An observer located on the sphere's surface, like our Earth's or a large sphere, like one located in a remote galaxy, will construct a picture centered on himself to be identical to the one centered inside the spherical shell of mass. Both observers will view the incoming radiation, emitted by the other observer, as redshifted, because they lay on each others radial line. The Universe is static and very old.

  14. Review of JT-60U experimental results in 2000

    International Nuclear Information System (INIS)

    2002-11-01

    The results of JT-60U experiments in 2000, from February to December, are reviewed. The performance under the full non-inductive current drive has been greatly advanced both in high β p H-mode plasmas and in reversed shear (RS) plasmas. In the high β p H-mode, with injection of the negative ion based neutral beam (NNB) of 360 keV and 4 MW into a high electron temperature plasma (T e (0) ∼ 13 keV), a high fusion triple product n D (0)T i (0)τ E = 2.0 x 10 20 keVm -3 s has been obtained at the plasma current of 1.5 MA, and the highest value of current drive efficiency of NNB (1.55 x 10 19 A/W/m 2 ) has been achieved. In RS, LHCD and NNB-CD were employed for current drive and high confinement (HH y2 ∼ 1.4) at high density (f GW ∼ 0.80) has been achieved. In the 110 GHz ECRF system, two more gyrotrons have been installed in addition to the one installed in 1999 and 1.5 MW was injected into the torus for 3 s. Complete stabilization of neoclassical tearing mode (NTM), realization of high confinement plasmas with T e ∼ T i , a high value (1 MA) of NNB-driven current in the high T e regime, and measurement of localized EC driven current were achieved with the upgraded EC system. The multiple pellet injection system has been newly installed. In high power NB heated plasmas, high-field-side pellet injection was more effective than low-field-side injection, and it extended the regime of high confinement high β p H-mode to a higher density. A new method, called CCS (Cauchy-condition surface method), for the control of the plasma position and shape in real-time became available and was found very useful especially for the control of plasma-wall clearance in LH and IC experiments. The active control of ITB strength by the switch of the injection direction of toroidal angular momentum was successfully demonstrated. In high triangularity H-mode plasmas, higher pressure and temperature at the edge pedestal were observed, which resulted in higher temperature and

  15. Integrating the results of user research into medical device development: insights from a case study.

    Science.gov (United States)

    Martin, Jennifer L; Barnett, Julie

    2012-07-19

    It is well established that considering users is an important aspect of medical device development. However it is also well established that there are numerous barriers to successfully conducting user research and integrating the results into product development. It is not sufficient to simply conduct user research, it must also be effectively integrated into product development. A case study of the development of a new medical imaging device was conducted to examine in detail how users were involved in a medical device development project. Two user research studies were conducted: a requirements elicitation interview study and an early prototype evaluation using contextual inquiry. A descriptive in situ approach was taken to investigate how these studies contributed to the product development process and how the results of this work influenced the development of the technology. Data was collected qualitatively through interviews with the development team, participant observation at development meetings and document analysis. The focus was on investigating the barriers that exist to prevent user data from being integrated into product development. A number of individual, organisational and system barriers were identified that functioned to prevent the results of the user research being fully integrated into development. The user and technological aspects of development were seen as separate work streams during development. The expectations of the developers were that user research would collect requirements for the appearance of the device, rather than challenge its fundamental concept. The manner that the user data was communicated to the development team was not effective in conveying the significance or breadth of the findings. There are a range of informal and formal organisational processes that can affect the uptake of user data during medical device development. Adopting formal decision making processes may assist manufacturers to take a more integrated and

  16. Results of remote follow-up and monitoring in young patients with cardiac implantable electronic devices.

    Science.gov (United States)

    Silvetti, Massimo S; Saputo, Fabio A; Palmieri, Rosalinda; Placidi, Silvia; Santucci, Lorenzo; Di Mambro, Corrado; Righi, Daniela; Drago, Fabrizio

    2016-01-01

    Remote monitoring is increasingly used in the follow-up of patients with cardiac implantable electronic devices. Data on paediatric populations are still lacking. The aim of our study was to follow-up young patients both in-hospital and remotely to enhance device surveillance. This is an observational registry collecting data on consecutive patients followed-up with the CareLink system. Inclusion criteria were a Medtronic device implanted and patient's willingness to receive CareLink. Patients were stratified according to age and presence of congenital/structural heart defects (CHD). A total of 221 patients with a device - 200 pacemakers, 19 implantable cardioverter defibrillators, and two loop recorders--were enrolled (median age of 17 years, range 1-40); 58% of patients were younger than 18 years of age and 73% had CHD. During a follow-up of 12 months (range 4-18), 1361 transmissions (8.9% unscheduled) were reviewed by technicians. Time for review was 6 ± 2 minutes (mean ± standard deviation). Missed transmissions were 10.1%. Events were documented in 45% of transmissions, with 2.7% yellow alerts and 0.6% red alerts sent by wireless devices. No significant differences were found in transmission results according to age or presence of CHD. Physicians reviewed 6.3% of transmissions, 29 patients were contacted by phone, and 12 patients underwent unscheduled in-hospital visits. The event recognition with remote monitoring occurred 76 days (range 16-150) earlier than the next scheduled in-office follow-up. Remote follow-up/monitoring with the CareLink system is useful to enhance device surveillance in young patients. The majority of events were not clinically relevant, and the remaining led to timely management of problems.

  17. Perfusion device for liver preservation ex vivo before transplantation: first experimental study

    Directory of Open Access Journals (Sweden)

    O. N. Reznik

    2017-01-01

    Full Text Available Introduction. Successful liver transplantation including from donors with a sudden irreversible cardiac arrest requires the use of modern hardware and technical support to maintain, select and sustain organ viability for the period from harvesting to transplantation to the recipient.Materials and methods. Hardware-software system (HSS developed by the Russian State Scientific Center for Robotics and Technical Cybernetics (RTC was used for testing of normothermic perfusion of donor’s liver ex vivo. The experiment was conducted on the isolated pig liver (Duroc breed in accordance with the ethical principles.Result. During perfusion spontaneous recovery of bile outflow through the cannula installed in the common bile duct (volume of bile released – 240 ml was observed, and the color and uniformity of the perfused liver did not differ from the normal parameters. Biochemical indicators were stabilized at the physiological values after 40 minutes of perfusion procedure.Conclusion. Isolated liver transplant was completely restored after 30 minutes of warm ischemia and was functioning well due to ex vivo perfusion procedure on the new perfusion device. The first case of the new device usage for normothermic liver ex vivo demonstrated hopeful results to be further investigated.

  18. Development and experimental study of oil-free capacitor module for plasma focus device

    Science.gov (United States)

    Sharma, Ravindra Kumar; Sharma, Archana

    2017-03-01

    This development is concerned with the compact capacitor module for a plasma focus device. Oil-free, non-standard geometry capacitors are designed and developed for high current delivery in sub-microseconds time. Metalized dielectric film based pulse capacitor becomes progressively less viable at currents above 10 kA. It is due to reliability and energy scaling difficulties, based on effects such as vaporization, high resistivity, and end connection. Bipolar electrolytic capacitors are also not preferred due to their limited life and comparatively low peak current delivery. Bi-axially oriented polypropylene (BOPP) film with extended aluminum foil is a combination to deliver moderately high power. But, electrically weak points, relative permittivity, and the edge gap margins have made its adoption difficult. A concept has been developed in lab for implementing the above combination in a less complex and costly manner. This paper concerns the development and testing process techniques for quite different hollow cylindrical, oil-free capacitors (4 μ F , 10 kV, 20 nH). Shot life of 1000 has been experimentally performed on the test bed at its rated energy density level. The technological methods and engineering techniques are now available and utilized for manufacturing and testing of BOPP film based oil-free capacitors.

  19. Iodine based radiopacity of experimental blood clots for testing of mechanical thrombectomy devices

    International Nuclear Information System (INIS)

    Luo, Zhong Hua; Chung, Alex; Choi, Gibok; Lin, Yih Huie; Pang, Huajin; Uchida, Barry T.; Pavcnik, Dusan; Jeromel, Miran; Keller, Frederick S.; Rösch, Josef

    2013-01-01

    Barium sulfate powder used for radiopacity of experimental blood clots (EBCs) for testing mechanical thrombectomy devices (MTD) has negative effects on EBCs mechanical properties. In vitro and in vivo exploration was performed to determine if the iodine based contrast medium will have less negative effects on the EBCs than barium. Fresh blood from 2 swine was used to create fibrinogen enhanced and thrombin initiated EBC in tubes. Iodine radiopacity was achieved by mixing the blood with 65% Iohexol or by soaking the EBCs for 2 or 24 hours in Iohexol. The EBCs opacified with barium served as controls. In vitro study: The EBCs were subjected to four tests, manual elongation, catheter injection, radiopacity and contrast wash out tests. In vivo study: The common carotid arteries of 2 swine were embolized by either barium EBC or EBC soaked for 24 hours in Iohexol. The duration of radiopacity of the different EBCs was compared. The EBCs opacified with Iohexol initially had higher radiopacity than the barium opacified EBCs. However, their opacity rapidly decreased with saline soaking and, particularly, after they were embolized in live animals. The mechanical properties of Iohexol opacified EBCs were inferior to barium opacified EBCs. The Iohexol mixed EBCs were less firm and elastic and half of them fragmented during catheter injection. The Iohexol soaked EBCs exhibited decreased tensile strength and elasticity compared to the barium EBCs. Compared to barium, iodine based contrast medium does not offer any advantage for opacifying EBCs

  20. Experimental results

    International Nuclear Information System (INIS)

    Turner, C.E.

    1980-01-01

    Concepts available for discussing stable crack growth have progressed sufficiently for similarities to be appreciated. Despite rather different starting points and diverse presentation, they are now tending to be complementary, each reinforcing by alternate arguments, the general trends and conclusions of various models for tearing instability

  1. Experimental devices for the spatio-temporal characterization of femtosecond high-power laser chains

    International Nuclear Information System (INIS)

    Gallet, Valentin

    2014-01-01

    One of the advantages of high-power femtosecond lasers (TW-PW) is to obtain, at the focus of a focusing optic, very high intensities up to 10 22 W.cm -2 (i.e. an electric field of 2.7 PV.m -1 . Therefore, these lasers chains necessarily deliver beams with large diameter (up to 40 cm) and very short pulses (of the order of tens of femto-seconds). As a consequence, the spatial and temporal properties of the pulse are generally not independent. Such dependence, called spatial-temporal coupling has the effect of increasing the pulse duration and the size of the focal spot, which can lead to a significant reduction of the maximum intensity at the focus. Metrology devices commonly used on these high-power femtosecond lasers allow retrieving the spatial and temporal profiles of the pulse only in an independent manner. The aim of this thesis was to develop techniques for measuring spatio-temporal couplings in order to quantify their effect and correct them in order to obtain the maximum intensity at focus. First of all, we adapted an existing technique of spatio-temporal characterization to the measurement of TW lasers. To avoid the issues induced at the focus, such as those related to jittering, measurements were performed on the collimated beam. By adding a reference source to the original device, we managed to take into account the measurement artifacts due to thermal and mechanical variations affecting the interferometer. With this improvement, it was possible to reconstruct the complete spatio-temporal profile of the beam, particularly its wavefront. However, the limitations imposed by this technique led to the development of a new measurement device. Based on a cross-correlation, this technique consists of making the laser beam to interfere with a part of itself, small enough not to be spatio-temporally distorted. We have also implemented a variant of this device for a single-shot measurement along one transverse dimension of the pulse. Using these techniques, we

  2. Active exercises utilizing a facilitating device in the treatment of lymphedema resulting from breast cancer therapy

    Directory of Open Access Journals (Sweden)

    de Fátima Guerreiro Godoy, Maria

    2010-01-01

    Full Text Available The aim of this study was to evaluate the reduction in volume of arm lymphedema secondary to breast cancer therapy utilizing an exercise facilitating device. Twenty-one women with arm lymphedema resulting from the surgical and radiotherapeutic treatment of breast cancer were randomly selected. Evaluation was made by water-displacement volumetry before and after each session. The patients were submitted to a series of active exercises using a facilitating device for four 12-minute sessions with intervals of 3 minutes between sessions in the sitting position with alignment of the spinal column. The lymphedematous arm was maintained under compression using a cotton-polyester sleeve. The active exercising device used was a mobile flexion bar fixed on a metal base at a height of 30 cm from the tabletop and at a distance of 10 cm from the patient’s body. The paired t-test was utilized for statistical analysis with an alpha error of 5% (p-value ≤0.05 being considered significant. The initial mean volume of the arms was 2,089.9 and the final volume was 2,023.0 mL with a mean loss of 66.9 mL (p-value <0.001. In conclusion, active exercises utilizing facilitating devices can contribute to a reduction in size of lymphedematous limbs.

  3. Research technique and experimental device for thermal conductivity measurements of refractory compounds

    International Nuclear Information System (INIS)

    Vishnevetskaya, I.A.; Petrov, V.A.

    1977-01-01

    Proposed is a new axial technique for determining thermal conductivity coefficient of solids at temperatures above 1000 deg C with the use of internal heating of specimens by passing electric current and with experimental determining the thermal flows on the lateral side of the working section of the specimen. This method is usable for investigating the thermal conductivity of materials whose surface radiation characteristics are unknown or unstable and for carrying out experiments not only in vacuum, but also in various atmospheres. The overall fiducial error of the results of the method is evaluated at 4-5 % within the range of temperatures between 1200 and 2300 K. A description of the experimental installation is given

  4. Irradiation devices for fusion reactor materials results obtained from irradiated lithium aluminate at the OSIRIS reactor

    International Nuclear Information System (INIS)

    Lefevre, F.; Thevenot, G.; Rasneur, B.; Botter, F.

    1986-06-01

    Studies about controlled fusion reactor of the Tokamak type require the examination of the radiation effects on the behaviour of various potential materials. Thus, in the first part of this paper, are presented the devices adapted to these materials studies and used in the OSIRIS reactor. In a second part, is described an experiment of irradiation ceramics used as candidates for breeding material and are given the first results

  5. Implications of medical devices quality assurance for implementation of experimental clinical trials

    International Nuclear Information System (INIS)

    Tirindelli Danesi, D.; Altavista, P.; Marino, C.; Benassi, M.

    1992-01-01

    The basis for all controlled clinical trials is the comparison of a new treatment with the standard treatment. The effect of the experimental procedure on the natural history of the disease is the result observed; but the interpretation of the results in cancer clinical experimentation is often difficult due to the variability of the clinical course of individual cancers in a given category. It has been possible to categorize cancers by means of prognostic factors and evaluate the results of therapy within each prognostic category, but there is still much variability within each category. The only way to determine whether or not a new treatment can be used for a particular form of cancer is to try it out on patients in clinical trials. The cooperative practice was originally induced by the realistic need for large sample sizes, but the variability in the interpretation of the results increased due to difficulties in comparing data. This is one of the main problems in cancer literature. These problems originate from inconsistent or incomplete reporting of the patient population under study, the treatment administered, the statistical methods employed to assess treatment efficacy and from differences in the definition of response criteria. This paper tries to outline the impact on the results evaluation of the lack of standardized prognostic factors and standardized therapeutic modalities in the selection and treatment of patients included in clinical trials

  6. Home-use TriPollar RF device for facial skin tightening: Clinical study results.

    Science.gov (United States)

    Beilin, Ghislaine

    2011-04-01

    Professional, non-invasive, anti-aging treatments based on radio-frequency (RF) technologies are popular for skin tightening and improvement of wrinkles. A new home-use RF device for facial treatments has recently been developed based on TriPollar™ technology. To evaluate the STOP™ home-use device for facial skin tightening using objective and subjective methods. Twenty-three female subjects used the STOP at home for a period of 6 weeks followed by a maintenance period of 6 weeks. Facial skin characteristics were objectively evaluated at baseline and at the end of the treatment and maintenance periods using a three-dimensional imaging system. Additionally, facial wrinkles were classified and subjects scored their satisfaction and sensations. Following STOP treatment, a statistically significant reduction of perioral and periorbital wrinkles was achieved in 90% and 95% of the patients, respectively, with an average periorbital wrinkle reduction of 41%. This objective result correlated well with the periorbital wrinkle classification result of 40%. All patients were satisfied to extremely satisfied with the treatments and all reported moderate to excellent visible results. The clinical study demonstrated the safety and efficacy of the STOP home-use device for facial skin tightening. Treatment can maintain a tighter and suppler skin with improvement of fine lines and wrinkles.

  7. Design and Experimental Verification of Chang'E-3 Moon-night Survival Device for APXS

    Science.gov (United States)

    Deng-yi, Chen; Jian, Wu; Yi-ming, Hu; Jin, Chang; Yi-zhong, Gong; Ming-sheng, Cai; Huan-yu, Wang; Jia-yu, Zhang; Xing-zhu, Cui; Jin-zhou, Wang

    2016-07-01

    The Active Particle X-ray Spectrometer (APXS) is one of the 4 scientific payloads of Chang'E-3 (CE-3) Lunar Rover, of which the scientific object is to identify the elements of lunar soil and rock samples by a carried radioactive source to trigger and detect the characteristic X-ray from them. According to the extreme temperature environment of the APXS and under the restriction of limited resources, this paper presents the design and analysis of the moon-night survival device RHU (radioisotope heating unit) for the APXS, and describes the corresponding environmental tests on its structure dynamics and moon-night survival. Finally, its reinstallation on the launch tower and the preliminary result of its on-orbit operation are introduced.

  8. Experimental and Numerical Studies on Tire Tread Block Friction Characteristics Based on a New Test Device

    Directory of Open Access Journals (Sweden)

    J. Wu

    2014-01-01

    Full Text Available A new device was developed for tire tread block slip friction tests. Then the friction characteristics were investigated under different loads and contact roads. Based on this, a friction model for contact between tire tread block and different road surfaces was developed. A finite element slip friction model of rubber block was developed for studying the tread contact stress, stiffness under different pattern slope angles, and ditch radius. Results indicate that friction coefficient between tread and ice road increases when the temperature decreases; different tread patterns have a certain influence on the friction coefficient; its average difference was less than 10%. Different roads impact the coefficient of friction more significantly; the greater the pattern slope, the greater the radial stiffness.

  9. Technical Note: Experimental results from a prototype high-field inline MRI-linac

    Energy Technology Data Exchange (ETDEWEB)

    Liney, G. P., E-mail: gary.liney@sswahs.nsw.gov.au [Department of Medical Physics, Ingham Institute for Applied Medical Research, Liverpool NSW 2170 (Australia); Dong, B.; Zhang, K. [Department of Medical Physics, Ingham Institute for Applied Medical Research, Liverpool NSW 2170 (Australia); and others

    2016-09-15

    Purpose: The pursuit of real-time image guided radiotherapy using optimal tissue contrast has seen the development of several hybrid magnetic resonance imaging (MRI)-treatment systems, high field and low field, and inline and perpendicular configurations. As part of a new MRI-linac program, an MRI scanner was integrated with a linear accelerator to enable investigations of a coupled inline MRI-linac system. This work describes results from a prototype experimental system to demonstrate the feasibility of a high field inline MR-linac. Methods: The magnet is a 1.5 T MRI system (Sonata, Siemens Healthcare) was located in a purpose built radiofrequency (RF) cage enabling shielding from and close proximity to a linear accelerator with inline (and future perpendicular) orientation. A portable linear accelerator (Linatron, Varian) was installed together with a multileaf collimator (Millennium, Varian) to provide dynamic field collimation and the whole assembly built onto a stainless-steel rail system. A series of MRI-linac experiments was performed to investigate (1) image quality with beam on measured using a macropodine (kangaroo) ex vivo phantom; (2) the noise as a function of beam state measured using a 6-channel surface coil array; and (3) electron contamination effects measured using Gafchromic film and an electronic portal imaging device (EPID). Results: (1) Image quality was unaffected by the radiation beam with the macropodine phantom image with the beam on being almost identical to the image with the beam off. (2) Noise measured with a surface RF coil produced a 25% elevation of background intensity when the radiation beam was on. (3) Film and EPID measurements demonstrated electron focusing occurring along the centerline of the magnet axis. Conclusions: A proof-of-concept high-field MRI-linac has been built and experimentally characterized. This system has allowed us to establish the efficacy of a high field inline MRI-linac and study a number of the technical

  10. Experimental study of ultra-low q discharges in the linear Extrap L1 device

    International Nuclear Information System (INIS)

    Brunsell, P.; Karlsson, Per.

    1991-01-01

    Linear pinch discharges with combined octupole and longitudinal magnetic fields are experimentally studied in the Extrap L1 device. Plasma currents are around I p =10 kA, plasma temperautres are up to T e =50 eV and plasma densities are of the order of n=5x10 21 m -3 . The plasma equilibria are in the ultra-low q (ULQ) regime corresponding to operation with plasma currents in excess of the Kruskal-Shafranov stability limit (q less than 1). The plasma current exhibits the typical time behaviour seen in toroidal ULQ experiments; the unstable setting up phase and the step-wise decay with current levels corresponding to q-values in windows between rational values. Longitudinal plasma current generated by radial plasma diffusion is seen, with amplitudes up to 30% of the externally driven current during the initial phase of the discharge. The effect of the octupole magnetic field on the ULQ confinement is investigated. The plasma temperature increases by more than a factor of two, for the optimum octupole rod current (I v =I p ), compared to the case without octupole field. A plasma current limitation for stable operation corresponding to q bigger than 1/2 is observed, excepts for low axial magnetic field strength. In the low axial field regime, the octupole field alone provides sufficient stabilization for operation with q less than 1/2. Plasma density and temperature both increase linearly with applied axial magnetic field. The density shows a strong, approximately exponential, dependence on discharge voltage. (au)

  11. Experimental device, corresponding forward model and processing of the experimental data using wavelet analysis for tomographic image reconstruction applied to eddy current nondestructive evaluation

    International Nuclear Information System (INIS)

    Joubert, P.Y.; Madaoui, N.

    1999-01-01

    In the context of eddy current non destructive evaluation using a tomographic image reconstruction process, the success of the reconstruction depends not only on the choice of the forward model and of the inversion algorithms, but also on the ability to extract the pertinent data from the raw signal provided by the sensor. We present in this paper, an experimental device designed for imaging purposes, the corresponding forward model, and a pre-processing of the experimental data using wavelet analysis. These three steps implemented with an inversion algorithm, will allow in the future to perform image reconstruction of 3-D flaws. (authors)

  12. Experimental results for a magnetic refrigerator using three different types of magnetocaloric material regenerators

    DEFF Research Database (Denmark)

    Engelbrecht, Kurt; Bahl, Christian Robert Haffenden; Nielsen, Kaspar Kirstein

    2011-01-01

    in an experimental device. This paper compares the performance of three magnetocaloric material candidates for AMRs, La(Fe,Co,Si)13, (La,Ca,Sr)MnO3 and Gd, in an experimental active magnetic regenerator with a parallel plate geometry. The performance of single-material regenerators of each magnetocaloric material...... family were compared. In an attempt to improve system performance, graded two-material regenerators were made from two different combinations of La(Fe,Co,Si)13 compounds having different magnetic transition temperatures. One combination of the La(Fe,Co,Si)13 materials yielded a higher performance, while...

  13. Experimental and Monte Carlo simulation studies of open cylindrical radon monitoring device using CR-39 detector

    Energy Technology Data Exchange (ETDEWEB)

    Rehman, Fazal-ur- E-mail: fazalr@kfupm.edu.sa; Jamil, K.; Zakaullah, M.; Abu-Jarad, F.; Mujahid, S.A

    2003-07-01

    There are several methods of measuring radon concentrations but nuclear track detector cylindrical dosimeters are widely employed. In this investigation, the consequence of effective volumes of the dosimeters on the registration of alpha tracks in a CR-39 detector was studied. In a series of experiments an optimum radius for a CR-39-based open cylindrical radon dosimeter was found to be about 3 cm. Monte Carlo simulation techniques hav been employed to verify the experimental results. In this context, a computer code Monte Carlo simulation dosimetry (MOCSID) was developed. Monte Carlo simulation experiments gave the optimum radius of the dosimeters as 3.0 cm. The experimental results are in good agreement with those obtained by Monte Carlo design calculations. In addition to this, plate-out effects of radon progeny were also studied. It was observed that the contribution of radon progeny ({sup 218}Po and {sup 214}Po) plated-out on the wall of the dosimeters increases with an increase of dosimeter radii and then decrease to 0 at a radius of about 3 cm if a point detector has been installed at the center of the dosimeter base. In the code MOCSID different types of random number generators were employed. The results of this research are very useful for designing an optimum size of radon dosimeters.

  14. Experimental and Monte Carlo simulation studies of open cylindrical radon monitoring device using CR-39 detector

    International Nuclear Information System (INIS)

    Rehman, Fazal-ur-; Jamil, K.; Zakaullah, M.; Abu-Jarad, F.; Mujahid, S.A.

    2003-01-01

    There are several methods of measuring radon concentrations but nuclear track detector cylindrical dosimeters are widely employed. In this investigation, the consequence of effective volumes of the dosimeters on the registration of alpha tracks in a CR-39 detector was studied. In a series of experiments an optimum radius for a CR-39-based open cylindrical radon dosimeter was found to be about 3 cm. Monte Carlo simulation techniques hav been employed to verify the experimental results. In this context, a computer code Monte Carlo simulation dosimetry (MOCSID) was developed. Monte Carlo simulation experiments gave the optimum radius of the dosimeters as 3.0 cm. The experimental results are in good agreement with those obtained by Monte Carlo design calculations. In addition to this, plate-out effects of radon progeny were also studied. It was observed that the contribution of radon progeny ( 218 Po and 214 Po) plated-out on the wall of the dosimeters increases with an increase of dosimeter radii and then decrease to 0 at a radius of about 3 cm if a point detector has been installed at the center of the dosimeter base. In the code MOCSID different types of random number generators were employed. The results of this research are very useful for designing an optimum size of radon dosimeters

  15. Virtual reality for mobility devices: training applications and clinical results: a review.

    Science.gov (United States)

    Erren-Wolters, Catelijne Victorien; van Dijk, Henk; de Kort, Alexander C; Ijzerman, Maarten J; Jannink, Michiel J

    2007-06-01

    Virtual reality technology is an emerging technology that possibly can address the problems encountered in training (elderly) people to handle a mobility device. The objective of this review was to study different virtual reality training applications as well as their clinical implication for patients with mobility problems. Computerized literature searches were performed using the MEDLINE, Cochrane, CIRRIE and REHABDATA databases. This resulted in eight peer reviewed journal articles. The included studies could be divided into three categories, on the basis of their study objective. Five studies were related to training driving skills, two to physical exercise training and one to leisure activity. This review suggests that virtual reality is a potentially useful means to improve the use of a mobility device, in training one's driving skills, for keeping up the physical condition and also in a way of leisure time activity. Although this field of research appears to be in its early stages, the included studies pointed out a promising transfer of training in a virtual environment to the real-life use of mobility devices.

  16. Scoliosis correction with shape-memory metal: results of an experimental study.

    Science.gov (United States)

    Wever, D J; Elstrodt, J A; Veldhuizen, A G; v Horn, J R

    2002-04-01

    The biocompatibility and functionality of a new scoliosis correction device, based on the properties of the shape-memory metal nickel-titanium alloy, were studied. With this device, the shape recovery forces of a shape-memory metal rod are used to achieve a gradual three-dimensional scoliosis correction. In the experimental study the action of the new device was inverted: the device was used to induce a scoliotic curve instead of correcting one. Surgical procedures were performed in six pigs. An originally curved squared rod, in the cold condition, was straightened and fixed to the spine with pedicle screws. Peroperatively, the memory effect of the rod was activated by heating the rod to 50 degrees C by a low-voltage, high-frequency current. After 3 and after 6 months the animals were sacrificed. The first radiographs, obtained immediately after surgery, showed in all animals an induced curve of about 40 degrees Cobb angle - the original curve of the rod. This curve remained constant during the follow-up. The postoperative serum nickel measurements were around the detection limit, and were not significantly higher compared to the preoperative nickel concentration. Macroscopic inspection after 3 and 6 months showed that the device was almost overgrown with newly formed bone. Corrosion and fretting processes were not observed. Histologic examination of the sections of the surrounding tissues and sections of the lung, liver, spleen and kidney showed no evidence of a foreign body response. In view of the initiation of the scoliotic deformation, it is expected that the shape-memory metal based scoliosis correction device also has the capacity to correct a scoliotic curve. Moreover, it is expected that the new device will show good biocompatibility in clinical application. Extensive fatigue testing of the whole system should be performed before clinical trials are initiated.

  17. Review of JT-60 experimental results from January to October, 1989

    International Nuclear Information System (INIS)

    1990-03-01

    Emphases in recent JT-60 experiments are placed on 1) improvements in plasma confinement with profile control and 2) steady state operation study. Both limiter and lower X-point divertor configurations were employed. The operating gas was hydrogen and, in some cases, helium. Improvements in confinement were demonstrated with pellet injection, LH current drive, high-Ti mode operation or ICRF. Current profile controllability with energetic electrons has been improved by the new LH launcher. The H-mode was achieved in limiter discharges with LH current drive for the first time. Nearly steady-state ELM-free H-mode with durations up to 3.3. sec was established without significant impurity accumulation. High-Ti and high-βp discharges were obtained in high field and low plasma current. Major experimental issues for the steady-state operation research were non-inductive current drive and He-ash exhaust. The neoclassical bootstrap current was confirmed in the wide range of βp. 30 keV helium NB was injected into NB heated lower X-point discharges, which produced centrally peaked birth profile of α-particles. A simple extension of the present result is promising for the helium exhaust in future device. (J.P.N.)

  18. An experimental method for detecting blood splatter from retractable phlebotomy and intravascular devices.

    Science.gov (United States)

    Haiduven, Donna; Applegarth, Shawn; Shroff, Miloni

    2009-03-01

    This study was designed to evaluate the safety of retractable intravascular devices in terms of their potential to produce blood splatter. A method for measuring this blood splatter designed by the research team was used to evaluate 3 specific intravascular devices. Scientific filters were positioned around the retraction mechanisms of the devices and weighed with an analytical scale, both before and after activation, in a simulated vein containing mock venous blood. The difference in filter mass was used as the primary unit of analysis to detect blood splatter. In addition, the filters were visually inspected for the presence or absence of blood. A paired t-test revealed significant differences in the prefilter and postfilter groups for 2 of the 3 devices tested (P blood was detected on 23% to 40% of the scientific filters for 2 of the devices. Our findings indicate a potential for bloodborne pathogen exposure with the use of intravascular devices with a retractable mechanism. This experiment may serve as a model in the design and implementation of future sharps device evaluation protocols to validate the threat of bloodborne pathogen exposure.

  19. Comparison of analysis results with experimental results for ENEA and CRIEPI rubber bearings

    International Nuclear Information System (INIS)

    Yoo, B.; Lee, J.H.; Koo, G.H.

    1993-01-01

    In this paper, the preliminary structural analyses of ENEA HDRB and CRIEPI NRB were performed by using computer code ABAQUS, and the analysis results were compared with the test results provided by Italy and Japan thru IAEA. The test data for the rubbers used for the fabrication of bearings were also provided thru IAEA, and were utilized for the formulation of the rubber models for the analyses. The analyses performed for the rubber bearings are for the combined compression and shear and for the compression. The analysis results show a good agreement in shear strains when compared with the test results of HDRB and NRB for the combined compression and shear and for the compression benchmarks, but show relatively smaller responses in displacements for the compression with offsets benchmarks. (author)

  20. Experimental Study of Current Discharge Behavior and Hard X-ray Anisotropy by APF Plasma Focus Device

    Science.gov (United States)

    Habibi, M.; Amrollahi, R.; Attaran, M.

    2009-03-01

    Amirkabir (APF) is a new Mather-type plasma focus device (16 kV, 36 μf, and 115 nH). In this work we present some experimental results as variation of discharge current signal respect to applied voltage at the optimum pressure, focusing time of plasma versus gas pressure, and variations of current discharge with different insulator sleeve dimensions. As we prospected optimum pressure tending to increase as we tried to higher voltage levels. The time taken by the current sheath to lift-off the insulator surface and therefore quality of pinched plasma depends on the length of the insulator sleeve. The results show that the insulator diameter can influence on pinch quality. Behavior of hard X-ray (HXR) signals with the pressure and also anisotropy of HXR investigated by the use of two scintillation detectors. The distribution of HXR intensity shows a large anisotropy with a maximum intensity between 22.5° and 45° and also between -22.5° and -67.5°.

  1. Transscleral sustained vasohibin-1 delivery by a novel device suppressed experimentally-induced choroidal neovascularization.

    Directory of Open Access Journals (Sweden)

    Hideyuki Onami

    Full Text Available We established a sustained vasohibin-1 (a 42-kDa protein, delivery device by a novel method using photopolymerization of a mixture of polyethylene glycol dimethacrylate, triethylene glycol dimethacrylate, and collagen microparticles. We evaluated its effects in a model of rat laser-induced choroidal neovascularization (CNV using a transscleral approach. We used variable concentrations of vasohibin-1 in the devices, and used an enzyme-linked immunosorbent assay and Western blotting to measure the released vasohibin-1 (0.31 nM/day when using the 10 μM vasohibin-1 delivery device [10VDD]. The released vasohibin-1 showed suppression activity comparable to native effects when evaluated using endothelial tube formation. We also used pelletized vasohibin-1 and fluorescein isothiocyanate-labeled 40 kDa dextran as controls. Strong fluorescein staining was observed on the sclera when the device was used for drug delivery, whereas pellet use produced strong staining in the conjunctiva and surrounding tissue, but not on the sclera. Vasohibin-1 was found in the sclera, choroid, retinal pigment epithelium (RPE, and neural retina after device implantation. Stronger immunoreactivity at the RPE and ganglion cell layers was observed than in other retinal regions. Significantly lower fluorescein angiography (FA scores and smaller CNV areas in the flat mounts of RPE-choroid-sclera were observed for the 10VDD, VDD (1 μM vasohibin-1 delivery device, and vasohibin-1 intravitreal direct injection (0.24 μM groups when compared to the pellet, non-vasohibin-1 delivery device, and intravitreal vehicle injection groups. Choroidal neovascularization can be treated with transscleral sustained protein delivery using our novel device. We offer a safer sustained protein release for treatment of retinal disease using the transscleral approach.

  2. Experimental geothermal well at Bad Schinznach. First results; Geothermiebohrung Bad Schinznach. Erste Resultate

    Energy Technology Data Exchange (ETDEWEB)

    Haering, M O [Haering Geo-Project, Steinmaur (Switzerland)

    1997-12-01

    The spa of Bad Schinznach (Canton Argovia, Switzerland) endeavours to cover its heating requirements with geothermal energy. A recently drilled well to a depth of 890 meters encountered the regional acquifer of thermal water (Oberer Muschelkalk, Triassic) in three levels. Preliminary results indicate a productive aquifer in the uppermost level with a wellhead temperature of 42 C. An additional exploitation of the bottomhole formation temperature of 63 C is envisaged. (orig.) [Deutsch] Das Bad Schinznach (Kanton Aargau, Schweiz) moechte im Rahmen der wirtschaftlichen Moeglichkeiten seinen Waermebedarf mit der Nutzung des Thermalwassers aus dem Oberen Muschelkalk (Trias) decken. Eine neulich abgeteufte Bohrung bis auf 890 Meter Tiefe hat die Formation auf drei Niveaus angetroffen. Erste Resultate deuten auf ein nutzbares Vorkommen im obersten Horizont mit einer Austrittstemperatur von 42 C. Eine zusaetzliche Nutzung der hohen Formationstemperatur von 63 C auf Endtiefe wird erwogen. (orig.)

  3. Experimental study of the vapour-liquid equilibria of HI-I-2-H2O ternary mixtures, Part 2: Experimental results at high temperature and pressure

    International Nuclear Information System (INIS)

    Larousse, B.; Lovera, P.; Borgard, J.M.; Roehrich, G.; Mokrani, N.; Maillault, C.; Doizi, D.; Dauvois, V.; Roujou, J.L.; Lorin, V.; Fauvet, P.; Carles, P.; Hartmann, J.M.

    2009-01-01

    In order to assess the choice of the sulphur-iodine thermochemical cycle for massive hydrogen production, a precise knowledge of the concentrations of the gaseous species (HI, I 2 , and H 2 O) in thermodynamic equilibrium with the liquid phase of the HI-I 2 -H 2 O ternary mixture is required, in a wide range of concentrations and for temperatures and pressures up to 300 degrees C and 50 bar. In the companion paper (Part 1) the experimental device was described, which enables the measurement of the total pressure and concentrations of the vapour phase (and thus the knowledge of the partial pressures of the different gaseous species) for the HI-I 2 -H 2 O mixture in the 20-140 degrees C range and up to 2 bar. This (Part 2) article describes the experimental device which enables similar measurements but now in the process domain. The results concerning concentrations in the vapour phase for the HI-I 2 -H 2 O initial mixture (with a global composition) in the 120-270 degrees C temperature range and up to 30 bar are presented. As previously, optical online diagnostics are used, based on recordings of infrared transmission spectra for HI and H 2 O and on UV/visible spectrometry for I 2 . The concentrations measured in the vapour phase are the first to describe the vapour composition under thermophysical conditions close to those of the distillation column. The experimental results are compared with a thermodynamic model and will help us to scale up and optimize the reactive distillation column we promote for the HI section of the sulphur-iodine cycle. (authors)

  4. Experimental device for the study of elastic and inelastic diffusion at high-energy He+-He collisions

    International Nuclear Information System (INIS)

    Dagnac, R.; Bordenave-Montesquieu, D.; Baudon, J.

    1978-01-01

    An experimental device for studying heavy particle collisions in the energy range 5 to 40 keV is described. Differential inelastic cross sections are measured by means of an energy loss analysis at scattering angles ranging from 0.5 to 4 0 . Typical energy loss spectra obtained at 6.5 keV and 40 keV are given for two diffusion angles. (author)

  5. Experimental results of two stage harmonic generation with picosecond pulses on the Stanford Mark III FEL

    International Nuclear Information System (INIS)

    Hooper, B.A.; Utah Univ., Salt Lake City; Stanford Univ., CA; Benson, S.V.; Madey, M.J.; Cutolo, A.; Naples Univ.

    1988-01-01

    We report experimental results on upper harmonic conversion using a lithium niobate and a beta barium borate crystal to quadruple the FEL light up into the visible and near infrared. The effects of finite linewidth, birefringent walk-off, and group velocity walk-off on conversion efficiency will be discussed with reference to the experimental results. (orig.)

  6. Dynamic Coefficients of a Tilting Pad With Active Lubrication: Comparison Between Theoretical and Experimental Results

    DEFF Research Database (Denmark)

    Cerda Varela, Alejandro Javier; Santos, Ilmar

    2015-01-01

    experimental results from the literature for industrial grade passive tilting pad bearings. This initial validation is followed by a comparison with experimental identification results obtained from a test rig featuring the active bearing design. Good overall agreement is observed in both configurations...

  7. Armature reaction effects on a high temperature superconducting field winding of an synchronous machine: experimental results

    DEFF Research Database (Denmark)

    Mijatovic, Nenad; Jensen, Bogi Bech

    2014-01-01

    This paper presents experimental results from the Superwind laboratory setup. Particular focus in the paper has been placed on describing and quantifying the influence of armature reaction on performance of the HTS filed winding. Presented experimental results have confirmed the HTS field winding...

  8. Results of duct-occlud or nit-occlud device occlusion of patent ductus arteriousus

    International Nuclear Information System (INIS)

    Zhou Aiqing; Gao Wei; Yu Zhiqing; Li Feng; Wang Rongfa

    2003-01-01

    Objective: To evaluate the safety and efficacy of transcatheter patent ductus arteriosus (PDA) occlusion with the Duct-Occlud or Nit-Occlud device. Methods: All 68 patients with PDA (less than 4 mm minimum diameter) underwent percutaneous Duct-Occlud or Nit-Occlud coil occlusion in the Department of Cardiology, Shanghai Children's Medical Center between April 1997 and December 2001. The mean age was 5.5 ± 2.8 years (range, 1.5 to 12 years); mean weight was 13.9 ± 9.8 kg (range, 11.0 to 59.0 kg). The mean minimum diameter of the PDA was 1.63 ± 0.62 mm (range, 0.5-3.8 mm). Standard right and left retrograde heart catheterization were performed and followed by coil occlusion. A 4Fr or 5Fr catheter was used for coil deployment. Results: All patients had successful implantation of Duct-Occlud or Nit-Occlud devices. Patients follow-up evaluations were conducted at hospital discharge and after 3, 6 months and 1 year. At the discharge day and 1 year later, all patients showed complete PDA closure by color flow echo Doppler imaging. The hospitalization were only 5 days. At a median follow-up interval of 3.5 years (1 month to 4.6 years), there were no hemolysis, coil migration, delayed recanalization, thromboembolic episodes, or bacterial endocarditis. Conclusions: Because of the specifically designed coil with coincidental geometry of the ductus arteriosus, so transcatheter closure of PDA with the Duct-Occlud device is safe and effective for the closure of small-to-moderate-size patient ductus arteriosus. Utilization of Nit-Occlud is limited, but somewhat useful for large PDAs which is needed to be further investigated

  9. Results of duct-occlud or nit-occlud device occlusion of patent ductus arteriousus

    Energy Technology Data Exchange (ETDEWEB)

    Aiqing, Zhou; Wei, Gao; Zhiqing, Yu; Feng, Li; Rongfa, Wang [Shanghai Second Medical Univ., Shanghai (China). Shanghai Xinhua Hospital

    2003-10-01

    Objective: To evaluate the safety and efficacy of transcatheter patent ductus arteriosus (PDA) occlusion with the Duct-Occlud or Nit-Occlud device. Methods: All 68 patients with PDA (less than 4 mm minimum diameter) underwent percutaneous Duct-Occlud or Nit-Occlud coil occlusion in the Department of Cardiology, Shanghai Children's Medical Center between April 1997 and December 2001. The mean age was 5.5 {+-} 2.8 years (range, 1.5 to 12 years); mean weight was 13.9 {+-} 9.8 kg (range, 11.0 to 59.0 kg). The mean minimum diameter of the PDA was 1.63 {+-} 0.62 mm (range, 0.5-3.8 mm). Standard right and left retrograde heart catheterization were performed and followed by coil occlusion. A 4Fr or 5Fr catheter was used for coil deployment. Results: All patients had successful implantation of Duct-Occlud or Nit-Occlud devices. Patients follow-up evaluations were conducted at hospital discharge and after 3, 6 months and 1 year. At the discharge day and 1 year later, all patients showed complete PDA closure by color flow echo Doppler imaging. The hospitalization were only 5 days. At a median follow-up interval of 3.5 years (1 month to 4.6 years), there were no hemolysis, coil migration, delayed recanalization, thromboembolic episodes, or bacterial endocarditis. Conclusions: Because of the specifically designed coil with coincidental geometry of the ductus arteriosus, so transcatheter closure of PDA with the Duct-Occlud device is safe and effective for the closure of small-to-moderate-size patient ductus arteriosus. Utilization of Nit-Occlud is limited, but somewhat useful for large PDAs which is needed to be further investigated.

  10. Latest results and developments from the Hybrid Illinois Device for Research and Applications

    Science.gov (United States)

    Rizkallah, Rabel; Andruczyk, Daniel; Jeckell, Zachary Jon; Shone, Andrew John; Johnson, Daniel Scott; Allain, Jean Paul; Curreli, Davide; Ruzic, David N.; The Hidra Team

    2017-10-01

    The Hybrid Illinois Device for Research and Applications (HIDRA) is a five-period, l = 2, m = 5, toroidal fusion device operated at the University of Illinois at Urbana-Champaign (UIUC). It has a major radius R0 = 0.72 m and minor radius a = 0.19 m. Initial heating is achieved with 2.45 GHz electron cyclotron resonance heating (ECRH) at an on-axis magnetic field of B0 = 0.087 T which can go as high as B0 = 0.5 T. HIDRA will mainly be used as a classical stellarator, but can also run as a tokamak. This allows for both steady-state and transient regime operations. Experiments on HIDRA will primarily tackle the issue of plasma-material interactions (PMI) in fusion, and focus on developing innovative plasma facing component (PFC) technologies. Currently, research on flowing liquid lithium PFCs meant to be tested inside the machine in real-time operation, is being carried on. The first experiments run on HIDRA started in early 2016 in the low field region. Now, HIDRA is also capable of running in the high field zone, allowing for more interesting experiments and meaningful outcomes. Here, we present some of the initial results coming from the machine.

  11. Initial Results of Optical Vortex Laser Absorption Spectroscopy in the HYPER-I Device

    Science.gov (United States)

    Yoshimura, Shinji; Asai, Shoma; Aramaki, Mitsutoshi; Terasaka, Kenichiro; Ozawa, Naoya; Tanaka, Masayoshi; Morisaki, Tomohiro

    2015-11-01

    Optical vortex beams have a potential to make a new Doppler measurement, because not only parallel but perpendicular movement of atoms against the beam axis causes the Doppler shift of their resonant absorption frequency. As the first step of a proof-of-principle experiment, we have performed the optical vortex laser absorption spectroscopy for metastable argon neutrals in an ECR plasma produced in the HYPER-I device at the National Institute for Fusion Science, Japan. An external cavity diode laser (TOPTICA, DL100) of which center wavelength was 696.735 nm in vacuum was used for the light source. The Hermite-Gaussian (HG) beam was converted into the Laguerre-Gaussian (LG) beam (optical vortex) by a computer-generated hologram displayed on the spatial light modulator (Hamamatsu, LCOS-SLM X10468-07). In order to make fast neutral flow across the LG beam, a high speed solenoid valve system was installed on the HYPER-I device. Initial results including the comparison of absorption spectra for HG and LG beams will be presented. This study was supported by NINS young scientists collaboration program for cross-disciplinary study, NIFS collaboration research program (NIFS13KOAP026), and JSPS KAKENHI grant number 15K05365.

  12. Construction and tests of a gamma device for experimental measurements of burnup of nuclear reactor fuel

    International Nuclear Information System (INIS)

    Brandao Junior, F.A.

    1982-01-01

    The gamma-scanning method is an important tool for the measurement of burnup of nuclear reactor fuel. The adequate knowledge of burnup allows for a better inventory of 'sensitive' fissile materials, better fuel management and provides insight on fuel behaviour and safety margins. This paper is related to the description, construction and operation of a first gamma scanning device, tested by irradiation of prototype PWR fuel pins, 14 cm long, in a Triga Mark-I reactor at very low power. Despite the limitations imposed by the low burnup, the experiment permitted a good checking of the main physical concepts and devices involved in the method. (Author) [pt

  13. Acute high-grade acromioclavicular dislocations treated with triple button device (MINAR): Preliminary results.

    Science.gov (United States)

    Cano-Martínez, José Antonio; Nicolás-Serrano, Gregorio; Bento-Gerard, Julio; Picazo-Marín, Francisco; Andrés-Grau, Josefina

    2016-11-01

    Describe the clinical and radiological results of triple button device in the treatment of high-grade AC dislocations (Rockwood, type V) and assess whether improves vertical and horizontal stability compared to the techniques previously described. This retrospective study included 39 patients with type V acromioclavicular dislocations treated with Twin Tail TightRope™ system (triple button device). Of the 39 patients, 33 (26 men and 7 women) were able to participate in clinical and radiographic follow up. At the time of surgery, the mean age was 25years±7(range, 17-49). All patients underwent bilateral-weighted Zanca (CC distance) and Alexander view (AC distance) as well as the Constant Score (CS) and Acromioclavicular Joint Instability Scoring System (ACJI). Radiological and clinical outcome was assessed during routine follow-up examinations preoperatively, postoperatively, 1, 3, 6 months and every year after the surgery. The presence of calcification, degenerative changes, mobilization of implants and bone resorption were also assessed. After a mean follow up of 25±4months (range 14-38), the results of the Constant (CS) were 94.1±5,5 (range 76-100) and test ACJI 87.3±9,8 (range 65-100), showing no significant differences with the uninjured shoulder (CS 95.8±2.5, range 83-100; ACJI 94.1±3.7, range 80-100). At final review, we observed that preoperative coracoclavicular distance (Zanca View) improved from 21,75±1.97mm to 8,73mm±0.75 and the acromioclavicular distance (Alexander View) from 12,65mm±1.99 to 0,35±0.3mm. Compared with healthy shoulder, these differences were not significant. There was no loss of reduction with this system in the vertical plane. 4 patients (12.12%) revealed signs of posterior instability with worse clinical test results. The presence of degenerative joint changes (6,06%), calcifications (27,2%) or mobilization of the implant (18,18%) was not associated with worse clinical outcomes. Twin Tail device using minimally invasive

  14. Comparing of Calculated and Experimental Results of CAPEX-U Device

    Czech Academy of Sciences Publication Activity Database

    Schmidt, Jiří; Koláček, Karel; Frolov, Oleksandr; Prukner, Václav; Štraus, Jaroslav

    2006-01-01

    Roč. 56, Suppl.B (2006), s. 371-376 ISSN 0011-4626. [Symposium on Plasma Physics and Technology/22nd./. Praha, 26.6.2006-29.6.2006] R&D Projects: GA ČR GA202/06/1324 Institutional research plan: CEZ:AV0Z20430508 Keywords : capillary discharge * numerical simulation * high-current pulse discharge Subject RIV: BL - Plasma and Gas Discharge Physics Impact factor: 0.568, year: 2006

  15. Fuel requirements for experimental devices in MTR reactors. A perturbation model for reactor core analysis

    International Nuclear Information System (INIS)

    Beeckmans de West-Meerbeeck, A.

    1991-01-01

    Irradiation in neutron absorbing devices, requiring high fast neutron fluxes in the core or high thermal fluxes in the reflector and flux traps, lead to higher density fuel and larger core dimensions. A perturbation model of the reactor core helps to estimate the fuel requirements. (orig.)

  16. Non-superconducting magnet structures for near-term, large fusion experimental devices

    International Nuclear Information System (INIS)

    File, J.; Knutson, D.S.; Marino, R.E.; Rappe, G.H.

    1980-10-01

    This paper describes the magnet and structural design in the following American tokamak devices: the Princeton Large Torus (PLT), the Princeton Divertor Experiment (PDX), and the Tokamak Fusion Test Reactor (TFTR). The Joint European Torus (JET), also presented herein, has a magnet structure evolved from several European programs and, like TFTR, represents state of the art magnet and structure design

  17. Proposal and experimental validation of analytical models for seismic and vibration isolation devices in nuclear and non-nuclear facilities

    International Nuclear Information System (INIS)

    Serino, G.; Bonacina, G.; Bettinali, F.

    1993-01-01

    Two analytical-experimental models of HDLRBs having different levels of approximations are presented. Comparison with available experimental data shows that a non-linear hysteretic model, defined by three rubber parameters only, allows a very good complete simulation of the dynamic behavior of the isolation devices. A simpler equivalent linear viscous model reproduces less exactly the experimental behavior, but permits a good prediction of peak response values in the earthquake analysis of an isolated structure, if bearing stiffness and damping parameters are properly selected. The models have been used in preliminary design and subsequent check of the isolation system of two different types of Gas-Insulated Electric Substations (GIS), in view of possible future installation of isolated GISes in areas of high seismic risk. (author)

  18. Clinical results and radiographic appearance of the Rashkind double umbrella device in patients with occlusion of the ductus arteriosus

    International Nuclear Information System (INIS)

    Galal, O.; Sinner, W. von; Azhari, N.; Al-Fadley, F.; De Moor, M.; Boecker, J.; Fawzy, M.E..; Al-Halees, Z.

    1997-01-01

    Background. The Rashkind double umbrella device for patent arterial duct occlusion has been used in many patients. Its radiographic appearance has not been sufficiently described. Objective. To present the varying radiographic appearances of the Rashkind double umbrella device on the chest X-ray. Materials and methods. The chest radiographs of 69 patients (median age 60 months; median weight 17 kg), who underwent closure of their patent arterial duct between March 1990 and August 1994, were reviewed. The following parameters were evaluated: (1) the size of the heart (cardio-thoracic ratio) and pulmonary vessels, (2) the position of the device in AP/PA and lateral projections. The results of occlusion of the patent arterial duct were also reviewed. Results. Sixty-two of 69 (90 %) pa- tients had complete occlusion after a follow-up between 2 months and 3 1 / 2 years. The cardio-thoracic ratio showed significant reduction at follow-up (P < 0.001). The two different size devices could be well differentiated in the AP and the lateral projection. In 14 patients (20 %) the device was in an asymmetrical position. There was no significant correlation between position of the device and success of occlusion in our material. Conclusion. Complete occlusion of the arterial duct using Rashkind double umbrella devices can be achieved in 90 % of our population. In 20 % the device will have an asymmetrical position. There is no correlation between asymmetrical position of the device in the chest radiograph and residual shunting. (orig.)

  19. The acceptance of virtual reality devices for cognitive rehabilitation: a report of positive results with schizophrenia.

    Science.gov (United States)

    da Costa, Rosa Maria Esteves Moreira; de Carvalho, Luís Alfredo Vidal

    2004-03-01

    This study presents a process of virtual environment development supported by a cognitive model that is specific to cognitive deficits of diverse disorders or traumatic brain injury, and evaluates the acceptance of computer devices by a group of schizophrenic patients. The subjects that participated in this experiment accepted to work with computers and immersive glasses and demonstrated a high level of interest in the proposed tasks. No problems of illness have been observed. This experiment indicated that further research projects must be carried out to verify the value of virtual reality technology for cognitive rehabilitation of psychiatric patients. The results of the current study represent a small but necessary step in the realization of that potential.

  20. Lagrangian methods for blood damage estimation in cardiovascular devices--How numerical implementation affects the results.

    Science.gov (United States)

    Marom, Gil; Bluestein, Danny

    2016-01-01

    This paper evaluated the influence of various numerical implementation assumptions on predicting blood damage in cardiovascular devices using Lagrangian methods with Eulerian computational fluid dynamics. The implementation assumptions that were tested included various seeding patterns, stochastic walk model, and simplified trajectory calculations with pathlines. Post processing implementation options that were evaluated included single passage and repeated passages stress accumulation and time averaging. This study demonstrated that the implementation assumptions can significantly affect the resulting stress accumulation, i.e., the blood damage model predictions. Careful considerations should be taken in the use of Lagrangian models. Ultimately, the appropriate assumptions should be considered based the physics of the specific case and sensitivity analysis, similar to the ones presented here, should be employed.

  1. Physico-chemical properties of aqueous drug solutions: From the basic thermodynamics to the advanced experimental and simulation results.

    Science.gov (United States)

    Bellich, Barbara; Gamini, Amelia; Brady, John W; Cesàro, Attilio

    2018-04-05

    The physical chemical properties of aqueous solutions of model compounds are illustrated in relation to hydration and solubility issues by using three perspectives: thermodynamic, spectroscopic and molecular dynamics simulations. The thermodynamic survey of the fundamental backgrounds of concentration dependence and experimental solubility results show some peculiar behavior of aqueous solutions with several types of similar solutes. Secondly, the use of a variety of experimental spectroscopic devices, operating under different experimental conditions of dimension and frequency, has produced a large amount of structural and dynamic data on aqueous solutions showing the richness of the information produced, depending on where and how the experiment is carried out. Finally, the use of molecular dynamics computational work is presented to highlight how the different types of solute functional groups and surface topologies organize adjacent water molecules differently. The highly valuable contribution of computer simulation studies in providing molecular explanations for experimental deductions, either of a thermodynamic or spectroscopic nature, is shown to have changed the current knowledge of many aqueous solution processes. While this paper is intended to provide a collective view on the latest literature results, still the presentation aims at a tutorial explanation of the potentials of the three methodologies in the field of aqueous solutions of pharmaceutical molecules. Copyright © 2018. Published by Elsevier B.V.

  2. Theoretical and experimental analysis of a solar thermoelectric power generation device based on gravity-assisted heat pipes and solar irradiation

    International Nuclear Information System (INIS)

    Zhang, Zhe; Li, Wenbin; Kan, Jiangming; Xu, Daochun

    2016-01-01

    Highlights: • A technical solution to the power supply of wireless sensor networks is presented. • The low voltage produced by device is boosted from around 1 V to more than 4 V. • An output current and voltage of the device is acquired as 343 mA and 1057 mV. • The device provides output power 362.56 mW in no electricity conditions. • The economic value of device is demonstrated. - Abstract: Solar thermoelectric power generation has been widely used to solve the power supply limitation issue for low-power wireless sensors because of its light weight, high reliability, low cost, lack of noise, and environmental friendliness. A solar thermoelectric power generation system based on gravity-assisted heat pipes and solar radiation is devised in this paper, and its behavior is continuously measured in realistic outdoor circumstances. The effects of key parameters, including solar luminous flux, load resistance, a proportional coefficient, and a relative Seebeck coefficient, are analyzed. Related experimental results show that the device can output a voltage of 1057 mV and an electrical current of 343 mA, resulting in an output power of 362.56 mW. With a stable external energy conversion module under aluminous flux of 7.81 × 10"4 lx, the voltage converted from the nature solar radiation is boosted from 1057 mV to 4.40 V, which meets the rated operating voltage of low power consumption components, such as low-power wireless sensors and ZigBee modules. An economic analysis of the system shows that the solar thermoelectric power generation device is both economically and technically competitive when it is applied in a low-voltage wireless sensor network.

  3. Percutaneous device closure of patent ductus arteriosus with pulmonary artery hypertension: long-term results.

    Science.gov (United States)

    Vijayalakshmi, Ishwarappa Balekundri; Setty, Natraj; Narasimhan, Chitra; Singla, Vivek; Manjunath, Cholenahalli Nanjappa

    2014-12-01

    Device closure of patent ductus arteriosus (PDA) is treatment of choice. But device closure in presence of pulmonary artery hypertension (PAH) remains a challenge. Data on patient selection, technical considerations, and complications are limited. To know the challenges and efficacy of device closure of PDA with PAH. Out of 1,325 cases of device closure of PDA, 246 (18.6%) with PAH formed the study material. To test the feasibility, chosen device is used to occlude PDA for ten minutes without oxygen inhalation. The device is released only if PAH reduced. PAH decreased in all except in 1 patient after closure with muscular ventricular septal occluder (MVSDO), pulmonary artery pressure (PAP) transiently increased (became supra-systemic), without significant reduction in aortic pressure. Device embolized in 8 patients (3.3%). Percutaneous retrieval was done in 4 (by snare in 2 and by fixing the cable to device in 2) and replaced with bigger devices. The surgical removal of the embolized MVSDO and ligation was done in 4 cases. All patients were on oral sildenafil and bosentan until PAP regressed to normal. Follow up was from 6 months to 9 years. No residual shunt in any patient on follow-up. The PAP regressed to normal in all except 5 cases (2.03%) of Down's syndrome with systemic PAP. Device closure of PDA with PAH is feasible, safe in all age groups. Temporary PDA occlusion with device is effective and time saving for evaluating pulmonary vascular reactivity. Device embolization in aorta is higher with severe PAH. Novel method of retrieval is effective. © 2014, Wiley Periodicals, Inc.

  4. Quantitative comparison between theoretical predictions and experimental results for the BCS-BEC crossover

    International Nuclear Information System (INIS)

    Perali, A.; Pieri, P.; Strinati, G.C.

    2004-01-01

    Theoretical predictions for the Bardeen-Cooper-Schrieffer-Bose-Einstein condensation crossover of trapped Fermi atoms are compared with recent experimental results for the density profiles of L 6 i. The calculations rest on a single theoretical approach that includes pairing fluctuations beyond mean-field. Excellent agreement with experimental results is obtained. Theoretical predictions for the zero-temperature chemical potential and gap at the unitarity limit are also found to compare extremely well with Quantum Monte Carlo simulations and with recent experimental results

  5. A New Experimental Device for Transapical Access of the Aortic and Mitral Valves as well as the Aorta in its Various Segments

    Directory of Open Access Journals (Sweden)

    Leonardo Paim

    Full Text Available Abstract Objective: To present the results of a new experimental device developed to facilitate the transapical access in endovascular treatment of structural heart diseases. It aims to reduce the risk of bleeding and complications in this type of access and demonstrate the device as a safe, fast and effective alternative. Methods: CorPoint is composed of three parts: introducer, base with coiled spring, and closing capsule. By rotating movements, the spring is introduced into the myocardium and progressively approaches the base to the surface of the heart. Guidewires and catheters are inserted through the hollow central part and, at the end of the procedure, the capsule is screwed over the base, therefore stopping any bleeding. Results: The device was implanted in 15 pigs, weighing 60 kg each, through an anterolateral thoracotomy, while catheters were introduced and guided by fluoroscopy. All animals had minimal bleeding; introducers with diameter up to 22 Fr were used and various catheters and guidewires were easily handled. After finishing the procedure, the closing capsule was attached and no bleeding was observed at the site. Conclusion: This new device has proved effective, fast and secure for the transapical access. This shows great potential for use, especially by ensuring an easier and direct access to the mitral and aortic valves; the shortest distance to be traveled by catheters; access to the ascending and descending aorta; decreased bleeding complications; decreased surgical time; and the possibility of allowing the technique to evolve and become totally percutaneous.

  6. Experimental device to determine the fatigue and crack growth properties in light water reactor conditions

    International Nuclear Information System (INIS)

    Klausnitzer, E.

    1984-01-01

    This is a comparison and assessment of components including autoclaves, loading systems, test frames, water treatment plant, recording of measured data (inductive transducers, strain gaugages) and control, measurement and recording systems of the experimental system. (DG) [de

  7. Experimental device for the X-ray energetic distribution measurement in a tokamak plasma

    International Nuclear Information System (INIS)

    Perez-Navarro, A.

    1977-01-01

    An experimental system to measure the X-ray spectrum in a tokamak plasma is described, emphasizing its characteristics: resolution, dead time and the pulse pile-up distortion effects on the X-ray spectra. (author) [es

  8. Habib EndoHPB: a novel endobiliary radiofrequency ablation device. An experimental study.

    Science.gov (United States)

    Zacharoulis, Dimitris; Lazoura, Olga; Sioka, Eleni; Potamianos, Spyros; Tzovaras, George; Nicholls, Joanna; Koukoulis, George; Habib, Nagy

    2013-02-01

    The Habib EndoHPB is a bipolar radiofrequency (RF) catheter developed to be introduced across malignant strictures of the bile ducts, so that RF energy can locally ablate the tumor prior to stent placement. This experiment aims to assess the ability of the catheter to coagulate the wall of the common bile duct (CBD) in a porcine model, to establish power requirement and time parameters and correlate them to the depth of thermal injury, and to assess the ease of operation of the device. The CBD was catheterized using the device in 20 pigs. RF energy was applied to the CBD wall with various generator settings. The pigs were sacrificed 24 hr after the application and the CBD was excised for histological analysis. The device was easy to handle. Statistically significant correlations between the power, the time of RF application, and the thermal injury depth were found. The Habib EndoHPB catheter can effectively deliver RF energy intraluminally in the porcine CBD. Clinical studies are warranted in order to define proper settings for safe and efficient use in malignant biliary obstruction.

  9. Comparison of numerical results with experimental data for single-phase natural convection in an experimental sodium loop

    International Nuclear Information System (INIS)

    Ribando, R.J.

    1979-01-01

    A comparison is made between computed results and experimental data for single-phase natural convection in an experimental sodium loop. The tests were conducted in the Thermal-Hydraulic Out-of-Reactor Safety (THORS) Facility, an engineering-scale high temperature sodium facility at the Oak Ridge National Laboratory used for thermal-hydraulic testing of simulated LMFBR subassemblies at normal and off-normal operating conditions. Heat generation in the 19 pin assembly during these tests was typical of decay heat levels. Tests were conducted both with zero initial forced flow and with a small initial forced flow. The bypass line was closed in most tests, but open in one. The computer code used to analyze these tests [LONAC (LOw flow and NAtural Convection)] is an ORNL-developed, fast running, one-dimensional, single-phase finite difference model for simulating forced and free convection transients in the THORS loop

  10. Conceptual design for irradiation device used to irradiate experimental LFR fuel element in TRIGA reactor, ACPR zone

    International Nuclear Information System (INIS)

    Ioan, M.

    2013-01-01

    The paper presents the main steps followed to conceive a small, versatile and rather cheep irradiation device used for irradiation of an experimental fuel element, specific for Lead cooled Fast Reactor (LFR), adapted to TRIGA reactor, ACPR zone. This device must be instrumented with at least 4 thermocouples and a pressure transducer. The fuel element (150 mm fuel pellets column) will be immersed in maximum 0.350 kg pure hot lead (400 deg C). The system has three protection barriers, as follows: first is the fuel tube, second is the lead container (maximum 20 mm inner diameter) and third is the external container (maximum 180 mm outside diameter). Before the reactor pulse, the temperature of the lead is set at the prescribed value using an electrical heater (300 W), coil on the second barrier. Outside the second barrier a very good thermal insulation is provided. (authors)

  11. Removal of arsenic from wastewaters by cryptocrystalline magnesite: complimenting experimental results with modelling

    CSIR Research Space (South Africa)

    Masindi, Vhahangwele

    2016-02-01

    Full Text Available -1 Journal of Cleaner Production Removal of arsenic from wastewaters by cryptocrystalline magnesite: complimenting experimental results with modelling Vhahangwele Masindi W. Mugera Gitari Keywords: Arsenic Mine leachates Cryptocrystalline...

  12. Experimental and modelling results of a parallel-plate based active magnetic regenerator

    DEFF Research Database (Denmark)

    Tura, A.; Nielsen, Kaspar Kirstein; Rowe, A.

    2012-01-01

    The performance of a permanent magnet magnetic refrigerator (PMMR) using gadolinium parallel plates is described. The configuration and operating parameters are described in detail. Experimental results are compared to simulations using an established twodimensional model of an active magnetic...

  13. Results of a customer-based, post-market surveillance survey of the HeRO access device.

    Science.gov (United States)

    Fusselman, Maureen

    2010-08-01

    In order to supplement post-market surveillance data on the HeRO vascular access device, a non-scientific customer survey was conducted to obtain quantitative data from dialysis providers caring for patients implanted with the device. Dialysis nurses involved in the care of HeRO patients were contacted in order to obtain post-implant device performance information for 10% of patients implanted with the device at the time of the survey. Thirty-eight dialysis units with a total of 65 HeRO patients participated in the survey. The total duration of HeRO device use was 348.4 months with an average use of 5.4 months. Thirty-eight of the 65 HeRO patients (58.5%) were reported to not have experienced any performance issues. There were 28 device performance incidents reported for the remaining 27 patients included in the survey. Occlusion was the single most commonly reported device-related performance issue with 18 patients (27.7%) experiencing 25 occlusive episodes. The majority of the patients who had an occlusion (66.7%) only experienced one occlusive event. Infections occurred in 4 patients (6.2%) with an overall infection rate of 0.38 per 1,000 patient days. Post-market clinical experience during the first 18 months of commercialization of the HeRO device were in line with expectations based on the results from initial clinical studies with the device. Device occlusion remains the most commonly reported performance issue with the reported rate in this survey less than that which was reported in earlier published studies with the device.

  14. Malfunction of cardiac devices after radiotherapy without direct exposure to ionizing radiation: mechanisms and experimental data.

    Science.gov (United States)

    Zecchin, Massimo; Morea, Gaetano; Severgnini, Mara; Sergi, Elisabetta; Baratto Roldan, Anna; Bianco, Elisabetta; Magnani, Silvia; De Luca, Antonio; Zorzin Fantasia, Anna; Salvatore, Luca; Milan, Vittorino; Giannini, Gianrossano; Sinagra, Gianfranco

    2016-02-01

    Malfunctions of cardiac implantable electronical devices (CIED) have been described after high-energy radiation therapy even in the absence of direct exposure to ionizing radiation, due to diffusion of neutrons (n) causing soft errors in inner circuits. The purpose of the study was to analyse the effect of scattered radiation on different types and models of CIED and the possible sources of malfunctions. Fifty-nine explanted CIED were placed on an anthropomorphous phantom of tissue-equivalent material, and a high-energy photon (15 MV) radiotherapy course (total dose = 70 Gy) for prostate treatment was performed. All devices were interrogated before and after radiation. Radiation dose, the electromagnetic field, and neutron fluence at the CIED site were measured. Thirty-four pacemakers (PM) and 25 implantable cardioverter-defibrillators (ICD) were analysed. No malfunctions were detected before radiation. After radiation a software malfunction was evident in 13 (52%) ICD and 6 (18%) PM; no significant electromagnetic field or photon radiations were detected in the thoracic region. Neutron capture was demonstrated by the presence of the (198)Au((197)Au + n) or (192)Ir((191)Ir + n) isotope activation; it was significantly greater in ICD than in PM and non-significantly greater in damaged devices. A greater effect in St Jude PM (2/2 damaged), Boston (9/11), and St Jude ICD (3/6) and in older ICD models was observed; the year of production was not relevant in PM. High-energy radiation can cause different malfunctions on CIED, particularly ICD, even without direct exposure to ionizing radiation due to scattered radiation of neutrons produced by the linear accelerator. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2015. For permissions please email: journals.permissions@oup.com.

  15. Design of passive directional acoustic devices using Topology Optimization - from method to experimental validation

    DEFF Research Database (Denmark)

    Christiansen, Rasmus Ellebæk; Fernandez Grande, Efren

    2016-01-01

    emission in two dimensions and is experimentally validated using three dimensional prints of the optimized designs. The emitted fields exhibit a level difference of at least 15 dB on axis relative to the off-axis directions, over frequency bands of approximately an octave. It is demonstrated to be possible...

  16. AlN/GaN-Based MOS-HEMT Technology: Processing and Device Results

    Directory of Open Access Journals (Sweden)

    S. Taking

    2011-01-01

    Full Text Available Process development of AlN/GaN MOS-HEMTs is presented, along with issues and problems concerning the fabrication processes. The developed technology uses thermally grown Al2O3 as a gate dielectric and surface passivation for devices. Significant improvement in device performance was observed using the following techniques: (1 Ohmic contact optimisation using Al wet etch prior to Ohmic metal deposition and (2 mesa sidewall passivation. DC and RF performance of the fabricated devices will be presented and discussed in this paper.

  17. Field emission device driven by self-powered contact-electrification: Simulation and experimental analysis

    Science.gov (United States)

    Chen, Xiangyu; Jiang, Tao; Sun, Zhuo; Ou-Yang, Wei

    2015-09-01

    A self-powered field emission device (FED) driven by a single-electrode tribo-electric nanogenerator (TENG) is demonstrated. The mechanical motion works as both a power supply to drive the FED and a control unit to regulate the amount of emitted electrons. By using the Fowler-Nordheim equation and Kirchhoff laws, a theoretical model of this self-powered FED is proposed, and accordingly the real-time output characteristics of the device are systematically investigated. It is found that the motion distance of the TENG controls switch-on of the FED and determines the charge amount for emission, while the motion velocity regulates the amplitude of emission current. The minimum contact area for the TENG to generate field emission is about 9 cm2, which can be improved by optimizing FED structure and the tribo-materials of TENG. The demonstrated concept of this self-powered FED as well as the proposed physical analysis can serve as guidance for further applications of FED in such fields of self-powered electronics and soft electronics.

  18. Field emission device driven by self-powered contact-electrification: Simulation and experimental analysis

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Xiangyu, E-mail: chenxiangyu@binn.cas.cn, E-mail: ouyangwei@phy.ecnu.edu.cn; Jiang, Tao [Beijing Institute of Nanoenergy and Nanosystems, Chinese Academy of Sciences, Beijing 100083 (China); Sun, Zhuo; Ou-Yang, Wei, E-mail: chenxiangyu@binn.cas.cn, E-mail: ouyangwei@phy.ecnu.edu.cn [Engineering Research Center for Nanophotonics and Advanced Instrument, Ministry of Education, Department of Physics, East China Normal University, 3663 North Zhongshan Road, Shanghai 200062 (China)

    2015-09-14

    A self-powered field emission device (FED) driven by a single-electrode tribo-electric nanogenerator (TENG) is demonstrated. The mechanical motion works as both a power supply to drive the FED and a control unit to regulate the amount of emitted electrons. By using the Fowler-Nordheim equation and Kirchhoff laws, a theoretical model of this self-powered FED is proposed, and accordingly the real-time output characteristics of the device are systematically investigated. It is found that the motion distance of the TENG controls switch-on of the FED and determines the charge amount for emission, while the motion velocity regulates the amplitude of emission current. The minimum contact area for the TENG to generate field emission is about 9 cm{sup 2}, which can be improved by optimizing FED structure and the tribo-materials of TENG. The demonstrated concept of this self-powered FED as well as the proposed physical analysis can serve as guidance for further applications of FED in such fields of self-powered electronics and soft electronics.

  19. Field emission device driven by self-powered contact-electrification: Simulation and experimental analysis

    International Nuclear Information System (INIS)

    Chen, Xiangyu; Jiang, Tao; Sun, Zhuo; Ou-Yang, Wei

    2015-01-01

    A self-powered field emission device (FED) driven by a single-electrode tribo-electric nanogenerator (TENG) is demonstrated. The mechanical motion works as both a power supply to drive the FED and a control unit to regulate the amount of emitted electrons. By using the Fowler-Nordheim equation and Kirchhoff laws, a theoretical model of this self-powered FED is proposed, and accordingly the real-time output characteristics of the device are systematically investigated. It is found that the motion distance of the TENG controls switch-on of the FED and determines the charge amount for emission, while the motion velocity regulates the amplitude of emission current. The minimum contact area for the TENG to generate field emission is about 9 cm 2 , which can be improved by optimizing FED structure and the tribo-materials of TENG. The demonstrated concept of this self-powered FED as well as the proposed physical analysis can serve as guidance for further applications of FED in such fields of self-powered electronics and soft electronics

  20. Some results of experimental investigation of super-deep penetration into the metal's targets

    International Nuclear Information System (INIS)

    Andilevko, S.K.; Roman, O.V.; Usherenko, S.M.; Shilkin, V.A.

    1994-01-01

    The phenomenon of Super-Deep Penetration (SDP) is briefly presented. Various experimental techniques, including that based on neutron-activated autoradiography (NAAR), for experimentally investigating this phenomenon are described. Results from a number of investigations in which the effect on SDP of initial target temperature, the dependence of the concentration on depth for different powder particles and the use of bimetallic targets, are reviewed. The complicated nature of the SDP process and the need for a wider range of experimental data if it is to be fully understood are discussed. (orig.)

  1. Initial results from the rebuilt EXTRAP T2R RFP device

    Science.gov (United States)

    Brunsell, P. R.; Bergsåker, H.; Cecconello, M.; Drake, J. R.; Gravestijn, R. M.; Hedqvist\\ad{2 }, A.; Malmberg, J.-A.

    2001-11-01

    The EXTRAP T2R thin shell reversed-field pinch (RFP) device has recently resumed operation after a major rebuild including the replacement of the graphite armour with molybdenum limiters, a fourfold increase of the shell time constant, and the replacement of the helical coil used for the toroidal field with a conventional solenoid-type coil. Wall-conditioning using hydrogen glow discharge cleaning was instrumental for successful RFP operation. Carbon was permanently removed from the walls during the first week of operation. The initial results from RFP operation with relatively low plasma currents in the range Ip = 70-100 kA are reported. RFP discharges are sustained for more than three shell times. Significant improvements in plasma parameters are observed, compared to operation before the rebuild. There is a substantial reduction in the carbon impurity level. The electron density behaviour is more shot-to-shot reproducible. The typical density is ne = 0.5-1×1019 m-3. Monitors of Hα line radiation indicate that the plasma wall interaction is more toroidally symmetric and that there is less transient gas release from the wall. The minimum loop voltage is in the range Vt = 28-35 V, corresponding to a reduction by a factor of two to three compared to the value before the rebuild.

  2. Early results with a monorail-stent-balloon device for endovascular treatment of renal artery stenosis

    International Nuclear Information System (INIS)

    Mueller-Huelsbeck, S.; Jahnke, T.; Grimm, J.; Behm, C.; Hilbert, C.; Frahm, C.; Biederer, J.; Brossmann, J.; Heller, M.

    2002-01-01

    Objective: To evaluate the technical feasibility of a new monorail-stent-balloon device for treatment of renal artery stenosis (RAS). Patients and Methods: During a study period of 18 months, 38 patients with proven RAS in 41 cases (hypertension n = 36, renal insufficiency n = 13) and indication for stenting (calicified ostial lesions n = 35, insufficient PTA n = 4, dissection n = 2) were enrolled into this prospective evaluation. Pre-mounted stents (Rx-Herculink TM 5 mm = 13, 6 mm = 34, 7 mm = 1) were implanted a transfermoral (n = 35) or transbrachial approach (n = 6). Mean grade and lengths of stenosis measured were 88% ±10 and 9 mm ±5. Results: Renal stent implantation was technically successful in all cases (100%). In 7 cases a second stent had to be implanted to cover the entire lesion. The transstenotic pressure drop decreased from 88 mmHg ± 10 before to 1 mmHg ± 1.8 after the procedure. Remaining stenosis measured 0.7% ±4.2. Serum creatine levels decreased from 1.9 mm/dl to 1.5 mg/dl (n.s.), blood pressure decreased from 178/94 mmHg to 148/79 mmHg (p [de

  3. The results of a consecutive series of dynamic posterior stabilizations using the PercuDyn device.

    Science.gov (United States)

    Canero, Gianfranco; Carbone, Stefano

    2015-11-01

    To evaluate the results of a consecutive series of patients affected by lumbar discogenic pain associated with facet pain and canal stenosis surgically treated with the PercuDyn device. From 2009, 129 consecutive patients (96 M, 33 F, mean age 62) were treated with posterior dynamic stabilization screws (PercuDyn). Inclusion criteria were minimum follow-up of 24 months; pain localized at the lumbar spine column alone or in association to lower limb radicular pain; magnetic resonance evidence of disc degeneration associated with facet degeneration and canal stenosis. Patients were clinically studied using VAS scale and Oswestry Disability Index (ODI); CT assessment of the neuroforamina and spinal canal areas was done at 1 month of follow-up. At 24 months of follow-up, 96 patients fulfilled the inclusion criteria. 96 intervertebral spaces were treated (85 levels L5-S1, 11 levels L4-L5). The VAS scale showed a statistically significant difference at 1 month, 6 months and 2 years with respect to the pre-operative value (p fashion (p return to daily activities. At longer follow-ups, 10 % of patients received revision surgery.

  4. 3D-FBK Pixel sensors: recent beam tests results with irradiated devices

    CERN Document Server

    Micelli, A; Sandaker, H; Stugu, B; Barbero, M; Hugging, F; Karagounis, M; Kostyukhin, V; Kruger, H; Tsung, J W; Wermes, N; Capua, M; Fazio, S; Mastroberardino, A; Susinno, G; Gallrapp, C; Di Girolamo, B; Dobos, D; La Rosa, A; Pernegger, H; Roe, S; Slavicek, T; Pospisil, S; Jakobs, K; Kohler, M; Parzefall, U; Darbo, G; Gariano, G; Gemme, C; Rovani, A; Ruscino, E; Butter, C; Bates, R; Oshea, V; Parker, S; Cavalli-Sforza, M; Grinstein, S; Korokolov, I; Pradilla, C; Einsweiler, K; Garcia-Sciveres, M; Borri, M; Da Via, C; Freestone, J; Kolya, S; Lai, C H; Nellist, C; Pater, J; Thompson, R; Watts, S J; Hoeferkamp, M; Seidel, S; Bolle, E; Gjersdal, H; Sjobaek, K N; Stapnes, S; Rohne, O; Su, D; Young, C; Hansson, P; Grenier, P; Hasi, J; Kenney, C; Kocian, M; Jackson, P; Silverstein, D; Davetak, H; DeWilde, B; Tsybychev, D; Dalla Betta, G F; Gabos, P; Povoli, M; Cobal, M; Giordani, M P; Selmi, L; Cristofoli, A; Esseni, D; Palestri, P; Fleta, C; Lozano, M; Pellegrini, G; Boscardin, M; Bagolini, A; Piemonte, C; Ronchin, S; Zorzi, N; Hansen, T E; Hansen, T; Kok, A; Lietaer, N; Kalliopuska, J; Oja, A

    2011-01-01

    The Pixel detector is the innermost part of the ATLAS experiment tracking device at the Large Hadron Collider (LHC), and plays a key role in the reconstruction of the primary and secondary vertices of short-lived particles. To cope with the high level of radiation produced during the collider operation, it is planned to add to the present three layers of silicon pixel sensors which constitute the Pixel Detector, an additional layer (Insertable B-Layer, or IBL) of sensors. 3D silicon sensors are one of the technologies which are under study for the IBL. 3D silicon technology is an innovative combination of very-large-scale integration (VLSI) and Micro-Electro-Mechanical-Systems (MEMS) where electrodes are fabricated inside the silicon bulk instead of being implanted on the wafer surfaces. 3D sensors, with electrodes fully or partially penetrating the silicon substrate, are currently fabricated at different processing facilities in Europe and USA. This paper reports on the 2010 June beam test results for irradi...

  5. Experimental Results and Numerical Simulation of the Target RCS using Gaussian Beam Summation Method

    Directory of Open Access Journals (Sweden)

    Ghanmi Helmi

    2018-05-01

    Full Text Available This paper presents a numerical and experimental study of Radar Cross Section (RCS of radar targets using Gaussian Beam Summation (GBS method. The purpose GBS method has several advantages over ray method, mainly on the caustic problem. To evaluate the performance of the chosen method, we started the analysis of the RCS using Gaussian Beam Summation (GBS and Gaussian Beam Launching (GBL, the asymptotic models Physical Optic (PO, Geometrical Theory of Diffraction (GTD and the rigorous Method of Moment (MoM. Then, we showed the experimental validation of the numerical results using experimental measurements which have been executed in the anechoic chamber of Lab-STICC at ENSTA Bretagne. The numerical and experimental results of the RCS are studied and given as a function of various parameters: polarization type, target size, Gaussian beams number and Gaussian beams width.

  6. Analysis and presentation of experimental results with examples, problems and programs

    CERN Document Server

    Christodoulides, Costas

    2017-01-01

    This book is intended as a guide to the analysis and presentation of experimental results. It develops various techniques for the numerical processing of experimental data, using basic statistical methods and the theory of errors. After presenting basic theoretical concepts, the book describes the methods by which the results can be presented, both numerically and graphically. The book is divided into three parts, of roughly equal length, addressing the theory, the analysis of data, and the presentation of results. Examples are given and problems are solved using the Excel, Origin, Python and R software packages. In addition, programs in all four languages are made available to readers, allowing them to use them in analyzing and presenting the results of their own experiments. Subjects are treated at a level appropriate for undergraduate students in the natural sciences, but this book should also appeal to anyone whose work involves dealing with experimental results.

  7. Experimental and analytical characterization of the 3D motion of particles in acoustofluidic devices

    DEFF Research Database (Denmark)

    Rossi, M.; Barnkob, Rune; Augustsson, P.

    2012-01-01

    and to examine the accuracy of analytical force predictions. Polystyrene spheres with diameter of 0.5µm and 5µm were displaced under controlled conditions in a long straight rectangular acoustofluidic microchannel, actuated in its 2-MHz resonance mode, a transverse half-wavelength standing acoustic wave......In this work we present an experimental and analytical study of the acoustophoretic motion of spherical polystyrene particles of different sizes. The primary aim is to understand the three-dimensional extension of the acoustic radiation force and the acoustic streaming-induced drag force...... for the smaller 0.5-µm particles. The experimental 3D data is used to validate new theoretical predictions of the streaming velocity....

  8. Experimental study of the performance of a very small repetitive plasma focus device in different working conditions

    Energy Technology Data Exchange (ETDEWEB)

    Goudarzi, S., E-mail: sgoudarzi@aeoi.org.ir; Babaee, H.; Esmaeli, A.; Nasiri, A. [Atomic Energy Organization of Iran, Plasma and Nuclear Fusion Research School, Nuclear Science and Technology Research Institute (Iran, Islamic Republic of)

    2017-01-15

    SORENA-1 is a very small repetitive Mather-type plasma focus device (20 J) that can operate at frequencies up to 1 Hz. This device has been designed and constructed in the Plasma and Nuclear Fusion Research School of the Nuclear Science and Technology Research Institute of Iran. In this article, the structure of SORENA-1 is described and results of experiments with Ar, Ne, and D{sub 2} working gases at several discharge voltages and initial pressures are presented and analyzed.

  9. EXPERIMENTAL STUDIES FOR DEVELOPMENT HIGH-POWER AUDIO SPEAKER DEVICES PERFORMANCE USING PERMANENT NdFeB MAGNETS SPECIAL TECHNOLOGY

    Directory of Open Access Journals (Sweden)

    Constantin D. STĂNESCU

    2013-05-01

    Full Text Available In this paper the authors shows the research made for improving high-power audio speaker devices performance using permanent NdFeB magnets special technology. Magnetic losses inside these audio devices are due to mechanical system frictions and to thermal effect of Joules eddy currents. In this regard, by special technology, were made conical surfaces at top plate and center pin. Analysing results obtained by modelling the magnetic circuit finite element method using electronic software package,was measured increase efficiency by over 10 %, from 1,136T to13T.

  10. Comparison of two devices for the treatment of keloid scars with the use of intralesional cryotherapy: An experimental study

    NARCIS (Netherlands)

    van Leeuwen, M.C.E.; Bulstra, A.E.J.; van der Veen, A.J.; Bloem, W.B.; van Leeuwen, P.A.M.; Niessen, F.B.

    2015-01-01

    Background: Intralesional (IL) cryotherapy is a new technique for the treatment of keloid scars, in which the scar is frozen from inside. Two cryodevices are available, which were recently evaluated. Both devices showed promising results, but differed in clinical outcome. To explain these

  11. Testing devices or experimental systems? Cancer clinical trials take the genomic turn.

    Science.gov (United States)

    Nelson, Nicole C; Keating, Peter; Cambrosio, Alberto; Aguilar-Mahecha, Adriana; Basik, Mark

    2014-06-01

    Clinical trials are often described as machine-like systems for generating specific information concerning drug safety and efficacy, and are understood as a component of the industrial drug development processes. This paper argues that contemporary clinical trials in oncology are not reducible to mere drug testing. Drawing on ethnographic fieldwork and interviews with researchers in the field of oncology from 2010 to 2013, we introduce a conceptual contrast between trials as testing machines and trials as clinical experimental systems to draw attention to the ways trials are increasingly being used to ask open-ended scientific questions. When viewed as testing machines, clinical trials are seen as a means to produce answers to straightforward questions and deviations from the protocol are seen as bugs in the system; but practitioners can also treat trials as clinical experimental systems to investigate as yet undefined problems and where heterogeneity becomes a means to produce novel biological or clinical insights. The rise of "biomarker-driven" clinical trials in oncology, which link measurable biological characteristics such as genetic mutations to clinical features such as a patient's response to a particular drug, exemplifies a trend towards more experimental styles of clinical work. These transformations are congruent with changes in the institutional structure of clinical research in oncology, including a movement towards more flexible, networked research arrangements, and towards using individual patients as model systems for asking biological questions. Copyright © 2014 Elsevier Ltd. All rights reserved.

  12. High Energy Beam Impacts on Beam Intercepting Devices: Advanced Numerical Methods and Experimental Set-up

    CERN Document Server

    Bertarelli, A; Carra, F; Cerutti, F; Dallocchio, A; Mariani, N; Timmins, M; Peroni, L; Scapin, M

    2011-01-01

    Beam Intercepting Devices are potentially exposed to severe accidental events triggered by direct impacts of energetic particle beams. State-of-the-art numerical methods are required to simulate the behaviour of affected components. A review of the different dynamic response regimes is presented, along with an indication of the most suited tools to treat each of them. The consequences on LHC tungsten collimators of a number of beam abort scenarios were extensively studied, resorting to a novel category of numerical explicit methods, named Hydrocodes. Full shower simulations were performed providing the energy deposition distribution. Structural dynamics and shock wave propagation analyses were carried out with varying beam parameters, identifying important thresholds for collimator operation, ranging from the onset of permanent damage up to catastrophic failure. Since the main limitation of these tools lies in the limited information available on constitutive material models under extreme conditions, a dedica...

  13. High Energy Beam Impacts on Beam Intercepting Devices: Advanced Numerical Methods and Experimental Set-Up

    CERN Document Server

    Bertarelli, A; Carra, F; Cerutti, F; Dallocchio, A; Mariani, N; Timmins, M; Peroni, L; Scapin, M

    2011-01-01

    Beam Intercepting Devices are potentially exposed to severe accidental events triggered by direct impacts of energetic particle beams. State-of-the-art numerical methods are required to simulate the behaviour of affected components. A review of the different dynamic response regimes is presented, along with an indication of the most suited tools to treat each of them. The consequences on LHC tungsten collimators of a number of beam abort scenarios were extensively studied, resorting to a novel category of numerical explicit methods, named Hydrocodes. Full shower simulations were performed providing the energy deposition distribution. Structural dynamics and shock wave propagation analyses were carried out with varying beam parameters, identifying important thresholds for collimator operation, ranging from the onset of permanent damage up to catastrophic failure. Since the main limitation of these tools lies in the limited information available on constitutive material models under extreme conditions, a dedica...

  14. Optically induced dielectropheresis sorting with automated medium exchange in an integrated optofluidic device resulting in higher cell viability.

    Science.gov (United States)

    Lee, Gwo-Bin; Wu, Huan-Chun; Yang, Po-Fu; Mai, John D

    2014-08-07

    We demonstrated the integration of a microfluidic device with an optically induced dielectrophoresis (ODEP) device such that the critical medium replacement process was performed automatically and the cells could be subsequently manipulated by using digitally projected optical images. ODEP has been demonstrated to generate sufficient forces for manipulating particles/cells by projecting a light pattern onto photoconductive materials which creates virtual electrodes. The production of the ODEP force usually requires a medium that has a suitable electrical conductivity and an appropriate dielectric constant. Therefore, a 0.2 M sucrose solution is commonly used. However, this requires a complicated medium replacement process before one is able to manipulate cells. Furthermore, the 0.2 M sucrose solution is not suitable for the long-term viability of cells. In comparison to conventional manual processes, our automated medium replacement process only took 25 minutes. Experimental data showed that there was up to a 96.2% recovery rate for the manipulated cells. More importantly, the survival rate of the cells was greatly enhanced due to this faster automated process. This newly developed microfluidic chip provided a promising platform for the rapid replacement of the cell medium and this was also the first time that an ODEP device was integrated with other active flow control components in a microfluidic device. By improving cell viability after cell manipulation, this design may contribute to the practical integration of ODEP modules into other lab-on-a-chip devices and biomedical applications in the future.

  15. Treatment of intracranial aneurysms by flow diverter devices: Long-term results from a single center

    International Nuclear Information System (INIS)

    Briganti, Francesco; Napoli, Manuela; Leone, Giuseppe; Marseglia, Mariano; Mariniello, Giuseppe; Caranci, Ferdinando; Tortora, Fabio; Maiuri, Francesco

    2014-01-01

    Highlights: • We report the long-term results (2–4 years) with Flow Diverter Devices (FDD) from a single-center. • We recommend the use of FDD for large-neck aneurysms of the ICA syphon. • We think that more sophisticate FDD will reduce the incidence of technical adverse events. - Abstract: Objectives: Flow-Diverter Devices (FDD) are a new generation stents designed for the treatment of the intracranial aneurysms. This article reports the long-term results (2–4 years) of this treatment from a single-center. Methods: From November 2008 to January 2012, 35 patients (29 females and 6 males; mean age 53.9 y) with 39 intracranial aneurysms were treated by FDD. Five patients (14.3%) had ruptured aneurysms and 30 (85.7%) had no previous hemorrhage. The procedures were performed in 5 patients (14.3%) with SILK and in 30 (85.7%) with PED. In 3 patients FDDs were used as a second treatment after failure of previous coiling (2 cases) or stenting (one case). The 39 aneurysms were in supraclinoid ICA in 26 (66.7%), cavernous ICA in 2 (5.1%), PCoA in 4 (10.2%), MCA in 5 (12.9%), SCA in 1 (2.6%) and PICA in 1 (2.6%). The aneurysms were small (<10 mm) in 32 cases (82%), large (11–25 mm) in 6 (15.3%) and giant in 1 (2.6%). The occlusion rate according to the aneurysm location, size and neck and the complications were evaluated. Results: Peri-procedural complications included transient dysarthria (2 patients), vasospasm with acute intra-stent aggregation (one), microwire rupture (one) and failure of the stent opening (one). The follow-up was made between 24 and 62 months (mean 41 months); clinical examination and CTA were performed at 1, 3, 6 and 12 months after the procedure. The complete occlusion was confirmed by CTA and DSA. MRI with angiographic-studies was taken every year. Complete occlusion was obtained in 35 aneurysms (92.1%) and subtotal in 3 (7.9%). Complete occlusion occurred at 3 months in 24 cases (68.6%), within 3 and 6 months in 9 (25.7%). The rate and

  16. Treatment of intracranial aneurysms by flow diverter devices: Long-term results from a single center

    Energy Technology Data Exchange (ETDEWEB)

    Briganti, Francesco, E-mail: frabriga@unina.it [Unit of Interventional Neuroradiology, Department of Advanced Biomedical Sciences, “Federico II” University, Via S.Pansini 5., 80131 Naples (Italy); Napoli, Manuela, E-mail: napoli.manuela@gmail.com [Department of Advanced Biomedical Sciences, “Federico II” University, Via S.Pansini 5., 80131 Naples (Italy); Leone, Giuseppe, E-mail: g.leonemd@gmail.com [Department of Advanced Biomedical Sciences, “Federico II” University, Via S.Pansini 5., 80131 Naples (Italy); Marseglia, Mariano, E-mail: mariano-marseglia@libero.it [Department of Advanced Biomedical Sciences, “Federico II” University, Via S.Pansini 5., 80131 Naples (Italy); Mariniello, Giuseppe, E-mail: giuseppe.mariniello@unina.it [Division of Neurosurgery, Department of Neurosciences, Reproductive and Odontostomatological Sciences, “Federico II” University, Via S.Pansini 5., 80131 Naples (Italy); Caranci, Ferdinando, E-mail: ferdinando.caranci@unina.it [Department of Advanced Biomedical Sciences, “Federico II” University, Via S.Pansini 5., 80131 Naples (Italy); Tortora, Fabio, E-mail: fabiotor@libero.it [Chair of Neuroradiology, “Magrassi Lanzara” Clinical-Surgical Department, Second University of Naples, Viale Colli Aminei 21, 80131 Naples (Italy); Maiuri, Francesco, E-mail: frmaiuri@unina.it [Division of Neurosurgery, Department of Neurosciences, Reproductive and Odontostomatological Sciences, “Federico II” University, Via S.Pansini 5., 80131 Naples (Italy)

    2014-09-15

    Highlights: • We report the long-term results (2–4 years) with Flow Diverter Devices (FDD) from a single-center. • We recommend the use of FDD for large-neck aneurysms of the ICA syphon. • We think that more sophisticate FDD will reduce the incidence of technical adverse events. - Abstract: Objectives: Flow-Diverter Devices (FDD) are a new generation stents designed for the treatment of the intracranial aneurysms. This article reports the long-term results (2–4 years) of this treatment from a single-center. Methods: From November 2008 to January 2012, 35 patients (29 females and 6 males; mean age 53.9 y) with 39 intracranial aneurysms were treated by FDD. Five patients (14.3%) had ruptured aneurysms and 30 (85.7%) had no previous hemorrhage. The procedures were performed in 5 patients (14.3%) with SILK and in 30 (85.7%) with PED. In 3 patients FDDs were used as a second treatment after failure of previous coiling (2 cases) or stenting (one case). The 39 aneurysms were in supraclinoid ICA in 26 (66.7%), cavernous ICA in 2 (5.1%), PCoA in 4 (10.2%), MCA in 5 (12.9%), SCA in 1 (2.6%) and PICA in 1 (2.6%). The aneurysms were small (<10 mm) in 32 cases (82%), large (11–25 mm) in 6 (15.3%) and giant in 1 (2.6%). The occlusion rate according to the aneurysm location, size and neck and the complications were evaluated. Results: Peri-procedural complications included transient dysarthria (2 patients), vasospasm with acute intra-stent aggregation (one), microwire rupture (one) and failure of the stent opening (one). The follow-up was made between 24 and 62 months (mean 41 months); clinical examination and CTA were performed at 1, 3, 6 and 12 months after the procedure. The complete occlusion was confirmed by CTA and DSA. MRI with angiographic-studies was taken every year. Complete occlusion was obtained in 35 aneurysms (92.1%) and subtotal in 3 (7.9%). Complete occlusion occurred at 3 months in 24 cases (68.6%), within 3 and 6 months in 9 (25.7%). The rate and

  17. Micronozzles: 3D numerical structural and gas dynamics modeling, fabrication, and preliminary experimental results

    Science.gov (United States)

    Borovkov, Alexei I.; Pyatishev, Evgenij N.; Lurie, Mihail S.; Korshunov, Andrey V.; Akulshin, Y. D.; Dolganov, A. G.; Sabadash, V. O.

    2001-02-01

    The tiny engines, founded on the principle of reactive thrust, are one of most perspective actuators developed by modern micromechanics. These engines can be applied for such apparent problems, as orientation and stabilization of small space objects, but also as local or distributed reactive thrust of new phylum of aerospace objects, for control of boundary layer of flying objects and in series of converting power devices of different purposes. Distinctive features of jet tiny engines are profitability (very large thrust-to-weight ratio) and high (milliseconds) response, which makes them to irreplaceable elements in control systems and, specially, in distributed power generations. These features are provided the minimum sizes, high pressure in working chambers and hypersonic velocity of propulsive jet. Topologically micronozzles are designed as the flat batch devices (3 layers as minimum). The lower and upper layers make flat walls of the nozzle and mainly influence on strength properties of the device. The mean layer reshapes geometry and determines gas dynamic characteristic of the nozzle. A special problem is the opening-up of the combustion-mixture, which is not esteemed in this work. It is necessary to allow for effect of considerable local stresses arising at the expense of static and dynamic loading at design of the jet tiny engines. Thermal gas dynamic processes in the chamber and nozzle determine the values and nature of these stresses, which are hardly studied for the microdevices. The priority is mathematical and experimental simulation of these processes. The most suitable object for initial phase of experimental simulation is the 'cold' engine. The demanded chamber static pressure is formed by external compressed air. In Laboratory of Microtechnology and MicroElectroMechanical Systems a number of such tiny engines with different shapes of the chamber's and the nozzles' surfaces were designed, made and tested. The engines were produced from photosensing

  18. Uav Photogrammetric Solution Using a Raspberry pi Camera Module and Smart Devices: Test and Results

    Science.gov (United States)

    Piras, M.; Grasso, N.; Jabbar, A. Abdul

    2017-08-01

    Nowadays, smart technologies are an important part of our action and life, both in indoor and outdoor environment. There are several smart devices very friendly to be setting, where they can be integrated and embedded with other sensors, having a very low cost. Raspberry allows to install an internal camera called Raspberry Pi Camera Module, both in RGB band and NIR band. The advantage of this system is the limited cost (light weight and their simplicity to be used and embedded. This paper will describe a research where a Raspberry Pi with the Camera Module was installed onto a UAV hexacopter based on arducopter system, with purpose to collect pictures for photogrammetry issue. Firstly, the system was tested with aim to verify the performance of RPi camera in terms of frame per second/resolution and the power requirement. Moreover, a GNSS receiver Ublox M8T was installed and connected to the Raspberry platform in order to collect real time position and the raw data, for data processing and to define the time reference. IMU was also tested to see the impact of UAV rotors noise on different sensors like accelerometer, Gyroscope and Magnetometer. A comparison of the achieved results (accuracy) on some check points of the point clouds obtained by the camera will be reported as well in order to analyse in deeper the main discrepancy on the generated point cloud and the potentiality of these proposed approach. In this contribute, the assembling of the system is described, in particular the dataset acquired and the results carried out will be analysed.

  19. DoSSiER: Database of Scientific Simulation and Experimental Results

    CERN Document Server

    Wenzel, Hans; Genser, Krzysztof; Elvira, Daniel; Pokorski, Witold; Carminati, Federico; Konstantinov, Dmitri; Ribon, Alberto; Folger, Gunter; Dotti, Andrea

    2017-01-01

    The Geant4, GeantV and GENIE collaborations regularly perform validation and regression tests for simulation results. DoSSiER (Database of Scientific Simulation and Experimental Results) is being developed as a central repository to store the simulation results as well as the experimental data used for validation. DoSSiER can be easily accessed via a web application. In addition, a web service allows for programmatic access to the repository to extract records in json or xml exchange formats. In this article, we describe the functionality and the current status of various components of DoSSiER as well as the technology choices we made.

  20. Clinical results and radiographic appearance of the Rashkind double umbrella device in patients with occlusion of the ductus arteriosus

    Energy Technology Data Exchange (ETDEWEB)

    Galal, O [King Faisal Specialist Hospital and Research Centre, Riyadh (Saudi Arabia); [Department of Cardiovascular Diseases, MBC 16, King Faisal Specialist Hospital and Research Centre, PO Box 3354, Riyadh 11211 (Saudi Arabia); Sinner, W von; Azhari, N; Al-Fadley, F; De Moor, M; Boecker, J; Fawzy, M E; Al-Halees, Z [King Faisal Specialist Hospital and Research Centre, Riyadh (Saudi Arabia)

    1997-12-01

    Background. The Rashkind double umbrella device for patent arterial duct occlusion has been used in many patients. Its radiographic appearance has not been sufficiently described. Objective. To present the varying radiographic appearances of the Rashkind double umbrella device on the chest X-ray. Materials and methods. The chest radiographs of 69 patients (median age 60 months; median weight 17 kg), who underwent closure of their patent arterial duct between March 1990 and August 1994, were reviewed. The following parameters were evaluated: (1) the size of the heart (cardio-thoracic ratio) and pulmonary vessels, (2) the position of the device in AP/PA and lateral projections. The results of occlusion of the patent arterial duct were also reviewed. Results. Sixty-two of 69 (90 %) pa- tients had complete occlusion after a follow-up between 2 months and 3{sup 1}/{sub 2} years. The cardio-thoracic ratio showed significant reduction at follow-up (P < 0.001). The two different size devices could be well differentiated in the AP and the lateral projection. In 14 patients (20 %) the device was in an asymmetrical position. There was no significant correlation between position of the device and success of occlusion in our material. Conclusion. Complete occlusion of the arterial duct using Rashkind double umbrella devices can be achieved in 90 % of our population. In 20 % the device will have an asymmetrical position. There is no correlation between asymmetrical position of the device in the chest radiograph and residual shunting. (orig.) With 7 figs., 12 refs.

  1. Variable friction device for structural control based on duo-servo vehicle brake: Modeling and experimental validation

    Science.gov (United States)

    Cao, Liang; Downey, Austin; Laflamme, Simon; Taylor, Douglas; Ricles, James

    2015-07-01

    Supplemental damping can be used as a cost-effective method to reduce structural vibrations. In particular, passive systems are now widely accepted and have numerous applications in the field. However, they are typically tuned to specific excitations and their performances are bandwidth-limited. A solution is to use semi-active devices, which have shown to be capable of substantially enhanced mitigation performance. The authors have recently proposed a new type of semi-active device, which consists of a variable friction mechanism based on a vehicle duo-servo drum brake, a mechanically robust and reliable technology. The theoretical performance of the proposed device has been previously demonstrated via numerical simulations. In this paper, we further the understanding of the device, termed Modified Friction Device (MFD) by fabricating a small scale prototype and characterizing its dynamic behavior. While the dynamics of friction is well understood for automotive braking technology, we investigate for the first time the dynamic behavior of this friction mechanism at low displacements and velocities, in both forward and backward directions, under various hydraulic pressures. A modified 3-stage dynamic model is introduced. A LuGre friction model is used to characterize the friction zone (Stage 1), and two pure stiffness regions to characterize the dynamics of the MFD once the rotation is reversed and the braking shoes are sticking to the drum (Stage 2) and the rapid build up of forces once the shoes are held by the anchor pin (Stage 3). The proposed model is identified experimentally by subjecting the prototype to harmonic excitations. It is found that the proposed model can be used to characterize the dynamics of the MFD, and that the largest fitting error arises at low velocity under low pressure input. The model is then verified by subjecting the MFD to two different earthquake excitations under different pressure inputs. The model is capable of tracking the

  2. Arthroscopic treatment of acute acromioclavicular dislocations using a double button device: Clinical and MRI results.

    Science.gov (United States)

    Loriaut, P; Casabianca, L; Alkhaili, J; Dallaudière, B; Desportes, E; Rousseau, R; Massin, P; Boyer, P

    2015-12-01

    Arthroscopic treatment of acute grade 3 and 4 acromioclavicular dislocation is controversial, due to the risk of recurrence and of postoperative reduction defect. The purpose of the present study was to investigate whether the healing of the acromioclavicular (AC) and coracoclavicular (CC) ligaments and the accurate 3D positioning parameters of the AC joint using MRI were correlated with satisfactory functional outcome. Thirty-nine patients were enrolled from 2009 to 2011 and managed arthroscopically by CC lacing using a double-button device. Clinical assessment included the Shoulder and Hand (QuickDash) score, Constant-Murley score and visual analog scale (VAS) for residual pain. Time and rate to return to work and return to sport were assessed according to type of sport and work. Postoperative complications were recorded. Radiological examination consisted of anteroposterior clavicle and lateral axillary radiographs. AC ligament healing and 3D joint congruency were assessed on MRI and correlated to the clinical results. Mean patient age was 35.7 years (range, 20-55). Mean follow-up was 42.3±10.6 months (range, 24-60). At final follow-up, mean QuickDash score, Constant score and VAS were respectively 1.7±4 (range, 0-11), 94.7±7.3 (range, 82-100) and 0.5±1.4 (range, 0-2). Thirty-five (90%) patients were able to resume work, including heavy manual labor, and sport. Radiology found accurate 3D joint congruency in 34 patients (87%) and CC and AC ligament healing in 36 (93%). Complications included reduction loss at 6 weeks in 3 patients, requiring surgical stabilization. Satisfactory functional results were associated with accurate AC joint congruency in the coronal and axial planes (P<0.05) and good AC and CC ligament healing (P<0.04). An initial 25% reduction defect in the coronal plane was not associated with poor functional results (P=0.07). Arthroscopic treatment by CC lacing satisfactorily restored ligament and joint anatomy in the present series. These

  3. Comparison of numerical results with experimental data for single-phase natural convection in an experimental sodium loop. [LMFBR

    Energy Technology Data Exchange (ETDEWEB)

    Ribando, R.J.

    1979-01-01

    A comparison is made between computed results and experimental data for a single-phase natural convection test in an experimental sodium loop. The test was conducted in the Thermal-Hydraulic Out-of-Reactor Safety (THORS) facility, an engineering-scale high temperature sodium loop at the Oak Ridge National Laboratory (ORNL) used for thermal-hydraulic testing of simulated Liquid Metal Fast Breeder Reactor (LMFBR) subassemblies at normal and off-normal operating conditions. Heat generation in the 19 pin assembly during the test was typical of decay heat levels. The test chosen for analysis in this paper was one of seven natural convection runs conducted in the facility using a variety of initial conditions and testing parameters. Specifically, in this test the bypass line was open to simulate a parallel heated assembly and the test was begun with a pump coastdown from a small initial forced flow. The computer program used to analyze the test, LONAC (LOw flow and NAtural Convection) is an ORNL-developed, fast-running, one-dimensional, single-phase, finite-difference model used for simulating forced and free convection transients in the THORS loop.

  4. Comparison of numerical results with experimental data for single-phase natural convection in an experimental sodium loop

    International Nuclear Information System (INIS)

    Ribando, R.J.

    1979-01-01

    A comparison is made between computed results and experimental data for a single-phase natural convection test in an experimental sodium loop. The test was conducted in the Thermal-Hydraulic Out-of-Reactor Safety (THORS) facility, an engineering-scale high temperature sodium loop at the Oak Ridge National Laboratory (ORNL) used for thermal-hydraulic testing of simulated Liquid Metal Fast Breeder Reactor (LMFBR) subassemblies at normal and off-normal operating conditions. Heat generation in the 19 pin assembly during the test was typical of decay heat levels. The test chosen for analysis in this paper was one of seven natural convection runs conducted in the facility using a variety of initial conditions and testing parameters. Specifically, in this test the bypass line was open to simulate a parallel heated assembly and the test was begun with a pump coastdown from a small initial forced flow. The computer program used to analyze the test, LONAC (LOw flow and NAtural Convection) is an ORNL-developed, fast-running, one-dimensional, single-phase, finite-difference model used for simulating forced and free convection transients in the THORS loop

  5. Nonlinear dynamics in experimental devices with compressed/expanded surfactant monolayers

    International Nuclear Information System (INIS)

    Higuera, M; Perales, J M; Vega, J M

    2014-01-01

    A theory is provided for a common experimental set up that is used to measure surface properties in surfactant monolayers. The set up consists of a surfactant monolayer (over a shallow liquid layer) that is compressed/expanded in a periodic fashion by moving in counter-phase two parallel, slightly immersed solid barriers, which vary the free surface area and thus the surfactant concentration. The simplest theory ignores the fluid dynamics in the bulk fluid, assuming spatially uniform surfactant concentration, which requires quite small forcing frequencies and provides reversible dynamics in the compression/expansion cycles. In this paper, we present a long-wave theory for not so slow oscillations that assumes local equilibrium but takes the fluid dynamics into account. This simple theory uncovers the physical mechanisms involved in the surfactant behavior and allows for extracting more information from each experimental run. The conclusion is that the fluid dynamics cannot be ignored, and that some irreversible dynamics could well have a fluid dynamic origin. (paper)

  6. Experimental and theoretical investigation of the iron core transformer for the EXTRAP T1 device

    International Nuclear Information System (INIS)

    Bures, M.

    1983-11-01

    The possibility of driving the discharge current of the toroidal EXTRAP T1 device, using the iron core transformer, is investigated. It is shown that the breakdown voltage 20 kV can be supplied, along the zero line of the vacuum magnetic field, at a time shorter than 1 μs. this is made possible by the transient build-up of the magnetic field in the iron core laminations. The plasma current rise time is determined by the evolution of the inductance and resistance of the discharge. This enables the plasma current to be built up to an amplitude I(sub)p=50 kA within 10-15 μs and sustained at this value during a steady-state period of 100 μs. The premagnetized iron core of the cross-sectional area 0.16 m 2 is sufficient to provide the necessary flux swing, if the saturation induction is not lower than 1 T. It is further concluded that the SiFe lamination is adequate for the present application. However, to reduce the stray field interfering with the zero line of the octupole field, a lamination of thickness d < 0.1 mm with high resistivity should be employed. The interlamination voltage should be reduced by segmenting the core. The steady-state is supplied by an 0.4Ω, 20 kV artificial line consisting of 20 μF capacitive elements. (author)

  7. Experimental device for the residential heating with heat pipe and electric heat storage blocks

    Energy Technology Data Exchange (ETDEWEB)

    Vasiliev, L L; Boldak, I M; Domorod, L S; Rabetsky, M I; Schirokov, E I [AN Belorusskoj SSR, Minsk (Belarus). Inst. Teplo- i Massoobmena

    1992-01-01

    Residential heating using electric heat storage blocks nowadays is an actual problem from the point of view of heat recovery and nature protection. In the Luikov Heat and Mass Transfer Institute a new residential electrical heater capable of heating chambers by controlling air temperature and heat output using heat pipes and an electric heat storage block was developed. This heater (BETA) is fed from the source of energy and during 7 h of night time accumulates energy sufficiently to heat 10 m{sup 3} during 24 h. Heating device BETA has a ceramic thermal storage block, electric heaters and a heat pipe with evaporator inside the ceramic block and constant temperature (65{sup o}C) finned condenser outside it. The condenser temperature could be controlled easily. BETA is compact, has high thermal response, accurate air temperature control and safe operation. Such types of residential heaters are necessary for heating residential and office building in the Mogilev and Gomel regions in Byelorussia which suffered after the Chernobyl catastrophe. (Author).

  8. Stab injury and device implantation within the brain results in inversely multiphasic neuroinflammatory and neurodegenerative responses

    Science.gov (United States)

    Potter, Kelsey A.; Buck, Amy C.; Self, Wade K.; Capadona, Jeffrey R.

    2012-08-01

    An estimated 25 million people in the US alone rely on implanted medical devices, ˜2.5 million implanted within the nervous system. Even though many devices perform adequately for years, the host response to medical devices often severely limits tissue integration and long-term performance. This host response is believed to be particularly limiting in the case of intracortical microelectrodes, where it has been shown that glial cell encapsulation and localized neuronal cell loss accompany intracortical microelectrode implantation. Since neuronal ensembles must be within ˜50 µm of the electrode to obtain neuronal spikes and local field potentials, developing a better understanding of the molecular and cellular environment at the device-tissue interface has been the subject of significant research. Unfortunately, immunohistochemical studies of scar maturation in correlation to device function have been inconclusive. Therefore, here we present a detailed quantitative study of the cellular events and the stability of the blood-brain barrier (BBB) following intracortical microelectrode implantation and cortical stab injury in a chronic survival model. We found two distinctly inverse multiphasic profiles for neuronal survival in device-implanted tissue compared to stab-injured animals. For chronically implanted animals, we observed a biphasic paradigm between blood-derived/trauma-induced and CNS-derived inflammatory markers driving neurodegeneration at the interface. In contrast, stab injured animals demonstrated a CNS-mediated neurodegenerative environment. Collectively these data provide valuable insight to the possibility of multiple roles of chronic neuroinflammatory events on BBB disruption and localized neurodegeneration, while also suggesting the importance to consider multiphasic neuroinflammatory kinetics in the design of therapeutic strategies for stabilizing neural interfaces.

  9. Comparison of Body Fat Results from 4 Bioelectrical Impedance Analysis Devices vs. Air Displacement Plethysmography in American Adolescent Wrestlers

    Directory of Open Access Journals (Sweden)

    Melissa M. Montgomery

    2017-10-01

    Full Text Available Background: Accurate and accessible methods of body composition are necessary to ensure health and safety of wrestlers during competition. The most valid and reliable instruments are expensive and relatively inaccessible to high school wrestlers; therefore, more practical technology is needed. Objective: To compare body fat percentage (BF% results from 4 bioelectrical impedance analysis (BIA devices to those from air displacement plethysmography (ADP in adolescent wrestlers. Methodology: 134 adolescent male and female wrestlers (1.72±0.9 m, 66.8±14.3 kg, 15.6±1.1 yrs. were tested for hydration and then completed 4 body composition tests with different BIA devices and one with Bod Pod. Relative and absolute agreement were assessed between each BIA device and ADP on a single day. Results: When compared with ADP, all devices demonstrated excellent reliability (ICC (2,1 range: 0.88-0.94, but questionable measurement error (SEM range: 2.3-3.6 %BF. Bland-Altman plots revealed that each bioelectrical impedance device we tested over-estimated body fat percent in high school wrestlers (range: 0.8-3.6 %BF and demonstrated wide 95% limits of agreement (range: 15.0-20.8 %BF compared to ADP. Conclusions: The devices investigated demonstrated reasonable measurement accuracy. However, wide margins of error of each device were noted. Caution should be taken when assessing adolescent wrestlers with lower amounts of body fat, as it may result in failing to identify those who do not meet the minimum body fat percentage for competition. The governing bodies should use the research data in the decision-making process regarding appropriate devices for use in their weight management programs.

  10. Usability of a new disposable autoinjector platform device: results of a formative study conducted with a broad user population

    Directory of Open Access Journals (Sweden)

    Lange J

    2015-06-01

    Full Text Available Jakob Lange,1 Philipp Richard,1 Nick Bradley2 1Ypsomed AG, Burgdorf, Switzerland; 2BERGO UK, Bearsden, Glasgow, UK Abstract: This article presents a late-stage formative usability study of an autoinjector platform device. Such devices are used for the subcutaneous delivery of biopharmaceuticals, primarily for self-administration by the patient. Previous usability work on autoinjectors reported in the literature has been specific to single indications. This study was instead conducted with a broad user population, defined to represent user characteristics across a range of indications. The goals of the study were to evaluate whether users could use the devices safely and effectively, and could understand the instructions for use (IFU as well as the accompanying training. Further objectives were to capture any usability issues and to obtain participants' subjective ratings on the IFU and training as well as the confidence and comfort in using the device. A total of 43 participants in 5 groups received training and performed simulated injections either into an injection pad or a mannequin. All participants were able to successfully use the device. The device was well appreciated by all users, with a reported degree of confidence in using the device of 98%, of user comfort of 93%, and of comprehensibility of IFU and training of 98%. These values are higher than other comparable results reported in the literature. The presence of both audible and visible feedback during injection was seen to be a significant factor contributing to injection success. The observation that the device can be safely and efficiently used by all tested user groups provides confidence that the device and IFU in their current form will pass future summative testing in specific applications. Keywords: human factors engineering, autoinjector, handling study, use error, instructions for use, YpsoMate™

  11. High energy nucleus-nucleus collisions at CERN: Signatures, physical observables and experimental results

    International Nuclear Information System (INIS)

    Harris, J.W.

    1988-02-01

    Experimental results on high energy nucleus-nucleus collisions have become available with the recent experiments at CERN utilizing 200 GeV/n oxygen and sulfur beams. Physics motivations for these experiments are presented: a description of predicted signatures for possible formation of a quark-gluon plasma and physical observables that are expected to provide important information for understanding the dynamics of these collisions. A presentation will be made of some of the first experimental results to emerge from this new field. 28 refs., 9 figs

  12. Mixed-mode chaotic circuit with Wien-bridge configuration: The results of experimental verification

    Energy Technology Data Exchange (ETDEWEB)

    Kilic, Recai [Erciyes University, Department of Electronic Engineering, 38039 Kayseri (Turkey)]. E-mail: kilic@erciyes.edu.tr

    2007-05-15

    In this paper, we deal with the experimentally implementation of inductorless Wien bridge-based mixed-mode chaotic circuit (MMCC) which is capable to exhibit both linear and nonlinear oscillations. The results of experimental implementation agree with the results of theoretical and computer simulation presented in literature. Since the proposed implementation of MMCC circuit uses different design blocks such as Wien bridge-based autonomous circuit part, CFOA (current feedback operational amplifier)-based floating inductance simulator, CFOA-based Chua's diode and switching mechanism, it offers very versatile chaotic circuit model for studying autonomous and nonautonomous chaotic dynamics.

  13. Mixed-mode chaotic circuit with Wien-bridge configuration: The results of experimental verification

    International Nuclear Information System (INIS)

    Kilic, Recai

    2007-01-01

    In this paper, we deal with the experimentally implementation of inductorless Wien bridge-based mixed-mode chaotic circuit (MMCC) which is capable to exhibit both linear and nonlinear oscillations. The results of experimental implementation agree with the results of theoretical and computer simulation presented in literature. Since the proposed implementation of MMCC circuit uses different design blocks such as Wien bridge-based autonomous circuit part, CFOA (current feedback operational amplifier)-based floating inductance simulator, CFOA-based Chua's diode and switching mechanism, it offers very versatile chaotic circuit model for studying autonomous and nonautonomous chaotic dynamics

  14. Experimental results for characterization of a tapered plastic optical fiber sensor based on SPR

    Science.gov (United States)

    Cennamo, N.; Galatus, R.; Zeni, L.

    2015-05-01

    The experimental results obtained with two different Plastic Optical Fiber (POF) geometries, tapered and not-tapered, for a sensor based on Surface Plasmon Resonance (SPR) are presented. SPR is used for determining the refractive index variations at the interface between a gold layer and a dielectric medium (aqueous medium). In this work SPR sensors in POF configurations, useful for bio-sensing applications, have been realized for the optimization of the sensitivity and experimentally tested. The results show as the sensitivity increases with the tapered POF configuration, when the refractive index of aqueous medium increases.

  15. An Autonomous System for Experimental Evolution of Microbial Cultures: Test Results Using Ultraviolet-C Radiation and Escherichia Coli.

    Science.gov (United States)

    Ouandji, Cynthia; Wang, Jonathan; Arismendi, Dillon; Lee, Alonzo; Blaich, Justin; Gentry, Diana

    2017-01-01

    At its core, the field of microbial experimental evolution seeks to elucidate the natural laws governing the history of microbial life by understanding its underlying driving mechanisms. However, observing evolution in nature is complex, as environmental conditions are difficult to control. Laboratory-based experiments for observing population evolution provide more control, but manually culturing and studying multiple generations of microorganisms can be time consuming, labor intensive, and prone to inconsistency. We have constructed a prototype, closed system device that automates the process of directed evolution experiments in microorganisms. It is compatible with any liquid microbial culture, including polycultures and field samples, provides flow control and adjustable agitation, continuously monitors optical density (OD), and can dynamically control environmental pressures such as ultraviolet-C (UV-C) radiation and temperature. Here, the results of the prototype are compared to iterative exposure and survival assays conducted using a traditional hood, UV-C lamp, and shutter system.

  16. Evaluating Tree Protection Devices: Effects on Growth and Survival–First-Year Results

    Science.gov (United States)

    L. R. Costello; R. H. Schmidt; Gregory A. Giusti

    1991-01-01

    The protection of seedlings from animal browsing is critical for the survival and growth of many tree species. This is particularly true in wildland areas and arid areas (McAuliffe, 1986), and oftentimes in urban areas. A variety of techniques and devices have been used to protect seedlings, from using straw stubble to milk cartons to plastic or metal screens. Recently...

  17. Mechanical thrombectomy in acute embolic stroke: preliminary results with the revive device.

    Science.gov (United States)

    Rohde, Stefan; Haehnel, Stefan; Herweh, Christian; Pham, Mirko; Stampfl, Sibylle; Ringleb, Peter A; Bendszus, Martin

    2011-10-01

    The purpose of this study was to evaluate the safety and technical feasibility of a new thrombectomy device (Revive; Micrus Endovascular) in the endovascular treatment of acute ischemic stroke. Ten patients with acute large vessel occlusions were treated with the Revive device between October 2010 and December 2010. Mean National Institutes of Health Stroke Scale on admission was 19.0; mean duration of symptoms was 172 minutes. Recanalization was assessed using the Thrombolysis In Cerebral Infarction score. Clinical outcome (National Institutes of Health Stroke Scale) after thrombectomy was determined on Day 1, at discharge, and at Day 30. Vessel recanalization (Thrombolysis In Cerebral Infarction 2b or 3) was successful in all patients without device-related complications. Mean National Institutes of Health Stroke Scale 24 hours after the intervention, at discharge, and at Day 30 was 14.0, 11.5, and 5.1, respectively. At Day 30, 6 patients had a clinical improvement of >8 points or an National Institutes of Health Stroke Scale of 0 to 1, 1 patient showed minor improvement, and 3 patients had died. Symptomatic intracranial hemorrhage occurred in 2 patients, of which 1 was fatal. Thrombectomy with the Revive device in patients with stroke with acute large vessel occlusions demonstrated to be technically safe and highly effective. Clinical safety and efficacy have to be established in larger clinical trials.

  18. The relevance of animal experimental results for the assessment of radiation genetic risks in man

    International Nuclear Information System (INIS)

    Stephan, G.

    1981-01-01

    No suitable data are available from man for the quantitative assessment of genetic radiation risk. Therefore, the results from experiments on animals must be utilized. Two hypotheses are presented here in drawing analogical conclusions from one species to another. Although the extrapolation of results from animal experiments remains an open question, the use of experimental results from mice seems to be justified for an assessment of the genetic radiation risk in man. (orig.) [de

  19. Testing the ISP method with the PARIO device: Accuracy of results and influence of homogenization technique

    Science.gov (United States)

    Durner, Wolfgang; Huber, Magdalena; Yangxu, Li; Steins, Andi; Pertassek, Thomas; Göttlein, Axel; Iden, Sascha C.; von Unold, Georg

    2017-04-01

    The particle-size distribution (PSD) is one of the main properties of soils. To determine the proportions of the fine fractions silt and clay, sedimentation experiments are used. Most common are the Pipette and Hydrometer method. Both need manual sampling at specific times. Both are thus time-demanding and rely on experienced operators. Durner et al. (Durner, W., S.C. Iden, and G. von Unold (2017): The integral suspension pressure method (ISP) for precise particle-size analysis by gravitational sedimentation, Water Resources Research, doi:10.1002/2016WR019830) recently developed the integral suspension method (ISP) method, which is implemented in the METER Group device PARIOTM. This new method estimates continuous PSD's from sedimentation experiments by recording the temporal evolution of the suspension pressure at a certain measurement depth in a sedimentation cylinder. It requires no manual interaction after start and thus no specialized training of the lab personnel. The aim of this study was to test the precision and accuracy of new method with a variety of materials, to answer the following research questions: (1) Are the results obtained by PARIO reliable and stable? (2) Are the results affected by the initial mixing technique to homogenize the suspension, or by the presence of sand in the experiment? (3) Are the results identical to the one that are obtained with the Pipette method as reference method? The experiments were performed with a pure quartz silt material and four real soil materials. PARIO measurements were done repetitively on the same samples in a temperature-controlled lab to characterize the repeatability of the measurements. Subsequently, the samples were investigated by the pipette method to validate the results. We found that the statistical error for silt fraction from replicate and repetitive measurements was in the range of 1% for the quartz material to 3% for soil materials. Since the sand fractions, as in any sedimentation method, must

  20. Thermal-hydraulically controlled blowdown tests in the experimental facility COSIMA to study PWR fuel behavior: experimental and theoretical results

    International Nuclear Information System (INIS)

    Class, G.; Hain, K.; Meyder, R.

    1978-01-01

    The fuel behavior in the blow-down phase of a LOCA is of importance for fuel rods with high internal pressure and high rod power, because of the effects on clad failure of the small cladding deformations occurring. The operating results of the COSIMA facility show that, on the basis of the new developments for measuring technique and fuel rod simulators performed, reactor relevant blow-down performances can be conducted in a controlled and reproduceable manner. The mechanical and thermal-hydraulic states occurring in the test bed may be subject to computational checking. This permits on one hand to improve the computing models and on the other yields a confirmation of the high state of development of the available computer codes. Therefore it appears that, with the results from COSIMA and the associated theoretical work in the field of the blow-down process, difficult to treat experimentally, an essential contribution to verifying the models for accident calculations is given. The work scheduled for the next about 1 1/2 years will serve to further support the rather preliminary results and to extend the range of then application. (orig.) [de

  1. New alternatives for laser vaporization of the prostate: experimental evaluation of a 980-, 1,318- and 1,470-nm diode laser device.

    Science.gov (United States)

    Wezel, Felix; Wendt-Nordahl, Gunnar; Huck, Nina; Bach, Thorsten; Weiss, Christel; Michel, Maurice Stephan; Häcker, Axel

    2010-04-01

    Several diode laser systems were introduced in recent years for the minimal-invasive surgical therapy of benign prostate enlargement. We investigated the ablation capacities, hemostatic properties and extend of tissue necrosis of different diode lasers at wavelengths of 980, 1,318 and 1,470 nm and compared the results to the 120 W GreenLight HPS laser. The laser devices were evaluated in an ex vivo model using isolated porcine kidneys. The weight difference of the porcine kidneys after 10 min of laser vaporization defined the amount of ablated tissue. Blood loss was measured in blood-perfused kidneys following laser vaporization. Histological examination was performed to assess the tissue effects. The side-firing 980 and 1,470 nm diode lasers displayed similar ablative capacities compared to the GreenLight HPS laser (n.s.). The 1,318-nm laser, equipped with a bare-ended fiber, reached a higher ablation rate compared to the other laser devices (each P laser with a bare-ended fiber reached the highest rate compared to the side-firing devices (each P diode lasers showed superior hemostatic properties compared to the GreenLight HPS laser (each P laser), respectively. The diode lasers offered similar ablative capacities and improved hemostatic properties compared to the 120 W GreenLight HPS laser in this experimental ex vivo setting. The higher tissue penetration of the diode lasers compared to the GreenLight HPS laser may explain improved hemostasis.

  2. U.S. Department of Energy Reference Model Program RM1: Experimental Results

    Energy Technology Data Exchange (ETDEWEB)

    Hill, Craig [Univ. of Minnesota, Minneapolis, MN (United States); Neary, Vincent Sinclair [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Gunawan, Budi [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Guala, Michele [Univ. of Minnesota, Minneapolis, MN (United States); Sotiropoulos, Fotis [Univ. of Minnesota, Minneapolis, MN (United States)

    2014-10-01

    The Reference Model Project (RMP), sponsored by the U.S. Department of Energy’s (DOE) Wind and Water Power Technologies Program within the Office of Energy Efficiency & Renewable Energy (EERE), aims at expediting industry growth and efficiency by providing non-proprietary Reference Models (RM) of MHK technology designs as study objects for open-source research and development (Neary et al. 2014a,b). As part of this program, MHK turbine models were tested in a large open channel facility at the University of Minnesota’s St. Anthony Falls Laboratory (UMN-SAFL). Reference Model 1 (RM2) is a 1:40 geometric scale dual-rotor axial flow horizontal axis device with counter-rotating rotors, each with a rotor diameter dT = 0.5m. Precise blade angular position and torque measurements were synchronized with three acoustic Doppler velocimeters (ADVs) aligned with each rotor and the midpoint for RM1. Flow conditions for each case were controlled such that depth, h = 1m, and volumetric flow rate, Qw = 2.425m3s-1, resulting in a hub height velocity of approximately Uhub = 1.05ms-1 and blade chord length Reynolds numbers of Rec ≈ 3.0x105. Vertical velocity profiles collected in the wake of each device from 1 to 10 rotor diameters are used to estimate the velocity recovery and turbulent characteristics in the wake, as well as the interaction of the counter-rotating rotor wakes. The development of this high resolution laboratory investigation provides a robust dataset that enables assessing turbulence performance models and their ability to accurately predict device performance metrics, including computational fluid dynamics (CFD) models that can be used to predict turbulent inflow environments, reproduce wake velocity deficit, recovery and higher order turbulent statistics, as well as device performance metrics.

  3. U.S. Department of Energy Reference Model Program RM1: Experimental Results.

    Energy Technology Data Exchange (ETDEWEB)

    Hill, Craig [Univ. of Minnesota, Minneapolis, MN (United States); Neary, Vincent Sinclair [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Gunawan, Budi [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Guala, Michele [Univ. of Minnesota, Minneapolis, MN (United States); Sotiropoulos, Fotis [Univ. of Minnesota, Minneapolis, MN (United States)

    2017-08-01

    The Reference Model Project (RMP), sponsored by the U.S. Department of Energy’s (DOE) Wind and Water Power Technologies Program within the Office of Energy Efficiency & Renewable Energy (EERE), aims at expediting industry growth and efficiency by providing nonproprietary Reference Models (RM) of MHK technology designs as study objects for opensource research and development (Neary et al. 2014a,b). As part of this program, MHK turbine models were tested in a large open channel facility at the University of Minnesota’s St. Anthony Falls Laboratory (UMN-SAFL). Reference Model 1 (RM1) is a 1:40 geometric scale dual-rotor axial flow horizontal axis device with counter-rotating rotors, each with a rotor diameter dT = 0.5m. Precise blade angular position and torque measurements were synchronized with three acoustic Doppler velocimeters (ADVs) aligned with each rotor and the midpoint for RM1. Flow conditions for each case were controlled such that depth, h = 1m, and volumetric flow rate, Qw = 2.425m3s-1, resulting in a hub height velocity of approximately Uhub = 1.05ms-1 and blade chord length Reynolds numbers of Rec ≈ 3.0x105. Vertical velocity profiles collected in the wake of each device from 1 to 10 rotor diameters are used to estimate the velocity recovery and turbulent characteristics in the wake, as well as the interaction of the counter-rotating rotor wakes. The development of this high resolution laboratory investigation provides a robust dataset that enables assessing turbulence performance models and their ability to accurately predict device performance metrics, including computational fluid dynamics (CFD) models that can be used to predict turbulent inflow environments, reproduce wake velocity deficit, recovery and higher order turbulent statistics, as well as device performance metrics.

  4. An experimental device for accurate ultrasounds measurements in liquid foods at high pressure

    International Nuclear Information System (INIS)

    Hidalgo-Baltasar, E; Taravillo, M; Baonza, V G; Sanz, P D; Guignon, B

    2012-01-01

    The use of high hydrostatic pressure to ensure safe and high-quality product has markedly increased in the food industry during the last decade. Ultrasonic sensors can be employed to control such processes in an equivalent way as they are currently used in processes carried out at room pressure. However, their installation, calibration and use are particularly challenging in the context of a high pressure environment. Besides, data about acoustic properties of food under pressure and even for water are quite scarce in the pressure range of interest for food treatment (namely, above 200 MPa). The objective of this work was to establish a methodology to determine the speed of sound in foods under pressure. An ultrasonic sensor using the multiple reflections method was adapted to a lab-scale HHP equipment to determine the speed of sound in water between 253.15 and 348.15 K, and at pressures up to 700 MPa. The experimental speed-of-sound data were compared to the data calculated from the equation of state of water (IAPWS-95 formulation). From this analysis, the way to calibrate cell path was validated. After this calibration procedure, the speed of sound could be determined in liquid foods by using this sensor with a relative uncertainty between (0.22 and 0.32) % at a confidence level of 95 % over the whole pressure domain.

  5. Developing a reproducible non-line-of-sight experimental setup for testing wireless medical device coexistence utilizing ZigBee.

    Science.gov (United States)

    LaSorte, Nickolas J; Rajab, Samer A; Refai, Hazem H

    2012-11-01

    The integration of heterogeneous wireless technologies is believed to aid revolutionary healthcare delivery in hospitals and residential care. Wireless medical device coexistence is a growing concern given the ubiquity of wireless technology. In spite of this, a consensus standard that addresses risks associated with wireless heterogeneous networks has not been adopted. This paper serves as a starting point by recommending a practice for assessing the coexistence of a wireless medical device in a non-line-of-sight environment utilizing 802.15.4 in a practical, versatile, and reproducible test setup. This paper provides an extensive survey of other coexistence studies concerning 802.15.4 and 802.11 and reports on the authors' coexistence testing inside and outside an anechoic chamber. Results are compared against a non-line-of-sight test setup. Findings relative to co-channel and adjacent channel interference were consistent with results reported in the literature.

  6. Experimental results on elongation control using dynamic input allocation at FTU

    International Nuclear Information System (INIS)

    Varano, G.; Boncagni, L.; Galeani, S.; Granucci, G.; Vitale, V.; Zaccarian, L.

    2011-01-01

    We report on the experimental results related to a recently proposed control scheme for the regulation of plasma elongation using the poloidal field coils available at FTU, already used for the horizontal position control. The proposed technique allows to realize elongation regulation as a secondary task using the same poloidal coils.

  7. Experimental validation of the twins prediction program for rolling noise. Pt.2: results

    NARCIS (Netherlands)

    Thompson, D.J.; Fodiman, P.; Mahé, H.

    1996-01-01

    Two extensive measurement campaigns have been carried out to validate the TWINS prediction program for rolling noise, as described in part 1 of this paper. This second part presents the experimental results of vibration and noise during train pass-bys and compares them with predictions from the

  8. Alignment procedure for the VIRGO interferometer: experimental results from the Frascati Prototype

    International Nuclear Information System (INIS)

    Babusci, D.; Giordano, G.; Matone, G.; Matone, L.; Sannibale, V.

    1996-07-01

    A small fixed-mirrors Michelson interferometer has been suggested for VIRGO. The experimental results are excellent and fully confirm the adequacy of the method. The minimum angular misalignment that can be detected in the present set-up is 10 nrad

  9. Experimental results of the effective water head in downcomer during reflood phase of a PWR LOCA

    International Nuclear Information System (INIS)

    Sudo, Yukio; Murao, Yoshio; Akimoto, Hajime

    1980-08-01

    The results and analysis of an experiment for the effective water head in downcomer with 50mm gap size are described. The main objective of the experiment was to clarify the effect of gap size on reflooding in a PWR LOCA. The effective water head in downcomer is the driving force for feeding emergency coolant into the core during reflood phase of a PWR LOCA. Discussions presented here follow those of a previous report in which experimental results and analysis were described for the case of 200mm gap size. Experimental Conditions were: Initial Wall Temperature = 200 -- 300 0 C, Back Pressure = 1 atm., Coolant Temperature = 71 -- 100 0 C, Extraction Water Velocity = 0 -- 2 cm/s, Gap Size = 50 mm. The effective water head history obtained in the experiment was compared with those predicted with Sudo's void fraction correlation. In the prediction, heat input to coolant was calculated from the response of measured wall temperature with heat condition analysis. The experimental results and analysis reveals that: (1) The effects of the gap size and initial wall temperature are evident, (2) The effect of extraction water velocity is negligible, and (3) The predicted history of effective water head is in good agreement with the experimental results except during the transient period in which the effective water head is descreasing. (author)

  10. F.E. analysis of seismic isolators: comparison with experimental results

    International Nuclear Information System (INIS)

    Fuller, K.N.G.; Gough, J.; Ahmadi, H.R.

    1998-01-01

    Analysis of seismic isolators is performed by the ABAQUS code. The force deformation behaviour of a circular layer of rubber bonded to rigid surface was investigated. This model is chosen because of its simplicity and the relatively short processing time required. A 3-dimensional model was used for finite element calculations. Comparison of calculated values with experimental results is shown

  11. Tribology of skin : review and analysis of experimental results for the friction coefficient of human skin

    NARCIS (Netherlands)

    Derler, S.; Gerhardt, L.C.

    2012-01-01

    In this review, we discuss the current knowledge on the tribology of human skin and present an analysis of the available experimental results for skin-friction coefficients. Starting with an overview on the factors influencing the friction behaviour of skin, we discuss the up-to-date existing

  12. Nuclear magnetic resonance. Present results and its application to renal pathology. Experimental study of hydronephrosis

    International Nuclear Information System (INIS)

    Bertrand, P.

    1987-01-01

    Results of proton nuclear magnetic resonance imaging and relaxation time measurement of experimental hydronephrosis in mice are presented. The study is preceded by a description of the physical principles underlying the phenomenon of nuclear magnetic resonance and of its biomedical applications and with a review of the clinical use of NMR imaging in renal pathology [fr

  13. Results of experimental research of the modes of short circuit in a traction network

    Directory of Open Access Journals (Sweden)

    P.Ye. Mykhalichenko

    2012-08-01

    Full Text Available In the article the results, namely oscillograms of the transitional feeder electric values obtained by the experimental tests of the short circuit modes in case of setting off different types of substation fast-acting switches are presented. The experiments were conducted on the operating electrified track sections of the Prydniprovs’ka Railway.

  14. Shear or bending? Experimental results on large t-shaped prestressed conrete beams

    NARCIS (Netherlands)

    Ensink, S.W.H.; Van der Veen, C.; De Boer, A.

    2015-01-01

    Experimental results of four shear tests on two large prestressed concrete beams are compared to nonlinear analysis and design code calculations. The beams have a length of 12 m and a depth of 1.3 m and are reinforced with stirrups and pre-tensioning. The four tests consist of a single point load at

  15. An Underlay Communication Channel for 5G Cognitive Mesh Networks: Packet Design, Implementation, Analysis, and Experimental Results

    Energy Technology Data Exchange (ETDEWEB)

    Tarek Haddadin; Stephen Andrew Laraway; Arslan Majid; Taylor Sibbett; Daryl Leon Wasden; Brandon F Lo; Lloyd Landon; David Couch; Hussein Moradi; Behrouz Farhang-Boroujeny

    2016-04-01

    This paper proposes and presents the design and implementation of an underlay communication channel (UCC) for 5G cognitive mesh networks. The UCC builds its waveform based on filter bank multicarrier spread spectrum (FB-MCSS) signaling. The use of this novel spread spectrum signaling allows the device-to-device (D2D) user equipments (UEs) to communicate at a level well below noise temperature and hence, minimize taxation on macro-cell/small-cell base stations and their UEs in 5G wireless systems. Moreover, the use of filter banks allows us to avoid those portions of the spectrum that are in use by macro-cell and small-cell users. Hence, both D2D-to-cellular and cellular-to-D2D interference will be very close to none. We propose a specific packet for UCC and develop algorithms for packet detection, timing acquisition and tracking, as well as channel estimation and equalization. We also present the detail of an implementation of the proposed transceiver on a software radio platform and compare our experimental results with those from a theoretical analysis of our packet detection algorithm.

  16. Micro-scale experimental study of Microbial-Induced Carbonate Precipitation (MICP) by using microfluidic devices

    Science.gov (United States)

    Wang, Y.; Soga, K.; DeJong, J. T.; Kabla, A.

    2017-12-01

    Microbial-induced carbonate precipitation (MICP), one of the bio-mineralization processes, is an innovative subsurface improvement technique for enhancing the strength and stiffness of soils, and controlling their hydraulic conductivity. These macro-scale engineering properties of MICP treated soils controlled by micro-scale factors of the precipitated carbonate, such as its content, amount and distribution in the soil matrix. The precipitation process itself is affected by bacteria amount, reaction kinetics, porous medium geometry and flow distribution in the soils. Accordingly, to better understand the MICP process at the pore scale a new experimental technique that can observe the entire process of MICP at the pore-scale was developed. In this study, a 2-D transparent microfluidic chip made of Polydimethylsiloxane (PDMS) representing the soil matrix was designed and fabricated. A staged-injection MICP treatment procedure was simulated inside the microfluidic chip while continuously monitored using microscopic techniques. The staged-injection MICP treatment procedure started with the injection of bacteria suspension, followed with the bacteria setting for attachment, and then ended with the multiple injections of cementation liquid. The main MICP processes visualized during this procedure included the bacteria transport and attachment during the bacteria injection, the bacteria attachment and growth during the bacteria settling, the bacteria detachment during the cementation liquid injection, the cementation development during the cementation liquid injection, and the cementation development after the completion of cementation liquid injection. It is suggested that the visualization of the main MICP processes using the microfluidic technique can improve understating of the fundamental mechanisms of MICP and consequently help improve the treatment technique for in situ implementation of MICP.

  17. Vertical Instability in EAST: Comparison of Model Predictions with Experimental Results

    International Nuclear Information System (INIS)

    Qian Jinping; Wan Baonian; Shen Biao; Xiao Bingjia; Sun Youwen; Shi Yuejiang; Lin Shiyao; Li Jiangang; Gong Xianzu

    2008-01-01

    Growth rates of the axisymmetric mode in elongated plasmas in the experimental advanced superconducting tokamak (EAST) are measured with zero feedback gains and then compared with numerically calculated growth rates for the reconstructed shapes. The comparison is made after loss of vertical position control. The open-loop growth rates were scanned with the number of vessel eigenmodes, which up to 20 is enough to make the growth rates settled. The agreement between the growth rates measured experimentally and the growth rates determined numerically is good. The results show that a linear RZIP model is essentially good enough for the vertical position feedback control.

  18. Experimental results for hydrocarbon refrigerant vaporization inside brazed plate heat exchangers at high pressure

    DEFF Research Database (Denmark)

    Desideri, Adriano; Ommen, Torben Schmidt; Wronski, Jorrit

    2016-01-01

    fluids at typical working conditions of ORC systems for low temperature waste heat recovery (WHR) applications. Based on these premises, a novel testrig has been recently designed and built at the Technical University of Denmark to simulate the evaporating condition occurring in a small capacity ORC...... power unit. In this contribution the preliminary experimental results obtained from the first experimental campaign carried out on the rig are reported. HFC-134a was selected as working fluid. The experiments were carried out at saturation temperature of 60, 70 and 80 °C and inlet and outlet qualities...

  19. A Laboratory Experimental Study: An FBG-PVC Tube Integrated Device for Monitoring the Slip Surface of Landslides

    Science.gov (United States)

    Zhang, Shaojie; Chen, Jiang; Teng, Pengxiao; Wei, Fangqiang; Chen, Qiao

    2017-01-01

    A new detection device was designed by integrating fiber Bragg grating (FBG) and polyvinyl chloride (PVC) tube in order to monitor the slip surface of a landslide. Using this new FBG-based device, a corresponding slope model with a pre-set slip surface was designed, and seven tests with different soil properties were carried out in laboratory conditions. The FBG sensing fibers were fixed on the PVC tube to measure strain distributions of PVC tube at different elevation. Test results indicated that the PVC tube could keep deformation compatible with soil mass. The new device was able to monitor slip surface location before sliding occurrence, and the location of monitored slip surface was about 1–2 cm above the pre-set slip surface, which basically agreed with presupposition results. The monitoring results are expected to be used to pre-estimate landslide volume and provide a beneficial option for evaluating the potential impact of landslides on shipping safety in the Three Gorges area. PMID:29084157

  20. An experimental device for characterizing degassing processes and related elastic fingerprints: Analog volcano seismo-acoustic observations

    Science.gov (United States)

    Spina, Laura; Morgavi, Daniele; Cannata, Andrea; Campeggi, Carlo; Perugini, Diego

    2018-05-01

    A challenging objective of modern volcanology is to quantitatively characterize eruptive/degassing regimes from geophysical signals (in particular seismic and infrasonic), for both research and monitoring purposes. However, the outcomes of the attempts made so far are still considered very uncertain because volcanoes remain inaccessible when deriving quantitative information on crucial parameters such as plumbing system geometry and magma viscosity. In order to improve our knowledge of volcanic systems, a novel experimental device, which is capable of mimicking volcanic degassing processes with different regimes and gas flow rates, and allowing for the investigation of the related seismo-acoustic emissions, was designed and developed. The benefits of integrating observations on real volcanoes with seismo-acoustic signals generated in laboratory are many and include (i) the possibility to fix the controlling parameters such as the geometry of the structure where the gas flows, the gas flow rate, and the fluid viscosity; (ii) the possibility of performing acoustic measurements at different azimuthal and zenithal angles around the opening of the analog conduit, hence constraining the radiation pattern of different acoustic sources; (iii) the possibility to measure micro-seismic signals in distinct points of the analog conduit; (iv) finally, thanks to the transparent structure, it is possible to directly observe the degassing pattern through the optically clear analog magma and define the degassing regime producing the seismo-acoustic radiations. The above-described device represents a step forward in the analog volcano seismo-acoustic measurements.

  1. Uncertainties and understanding of experimental and theoretical results regarding reactions forming heavy and superheavy nuclei

    Science.gov (United States)

    Giardina, G.; Mandaglio, G.; Nasirov, A. K.; Anastasi, A.; Curciarello, F.; Fazio, G.

    2018-02-01

    Experimental and theoretical results of the PCN fusion probability of reactants in the entrance channel and the Wsur survival probability against fission at deexcitation of the compound nucleus formed in heavy-ion collisions are discussed. The theoretical results for a set of nuclear reactions leading to formation of compound nuclei (CNs) with the charge number Z = 102- 122 reveal a strong sensitivity of PCN to the characteristics of colliding nuclei in the entrance channel, dynamics of the reaction mechanism, and excitation energy of the system. We discuss the validity of assumptions and procedures for analysis of experimental data, and also the limits of validity of theoretical results obtained by the use of phenomenological models. The comparison of results obtained in many investigated reactions reveals serious limits of validity of the data analysis and calculation procedures.

  2. Preliminary results on an innovative plasmonic device for macromolecules analysis and sequencing

    KAUST Repository

    Francardi, Marco; Candeloro, Patrizio; Malara, Natalia Maria; Gentile, Francesco T.; Coluccio, Maria Laura; Perozziello, Gerardo; Gaggero, Aleesandro; De Angelis, Francesco De; Cherubini, Enrico; Di Fabrizio, Enzo M.

    2013-01-01

    In this work we present the fabrication and theoretical simulation for a new device constituted by a on Substrate Plasmonic Antenna (SPA) combined with a bio-functionalized Atomic Force Microscopy (AFM) cantilever. This device could represent a new strategy to sequence and analyze a single protein or DNA. The idea is to use an SPA composed of an innovative "wedding cake"shaped grating (WCG), in order to excite a Surface Plasmon Polariton (SPP) mode, and a 30-tilted Plasmonic Antenna (PA), able to compress adiabatically the SPP until the tip. The Plasmonic device is placed inside an electrical contact that could be used to unfold protein molecules or DNA. A bio-functionalized AFM tip can be used to fish a single biological element and for alignment with the SPA. Then the unfolded element could be scanned close to the PA and a Tip Enhanced Raman Signal (TERS) can be recorded from the biomolecule. The spatial resolution is limited by the size of the radius of curvature of the antenna, which in this work is about 15 nm, while the vertical scanning is controlled by the piezoelectric of the AFM set up. In this work we demonstrate the possibility to fabricate this innovative plasmonic device and we report FDTD simulations of the innovative WCG. The FDTD simulations show the generation of a plasmonic mode that, coupled with the antenna, give rise to an adiabatic compression which produce an increase of the electric field of about 40 times. © 2013 Elsevier B.V. All rights reserved.

  3. Preliminary results on an innovative plasmonic device for macromolecules analysis and sequencing

    KAUST Repository

    Francardi, Marco

    2013-11-01

    In this work we present the fabrication and theoretical simulation for a new device constituted by a on Substrate Plasmonic Antenna (SPA) combined with a bio-functionalized Atomic Force Microscopy (AFM) cantilever. This device could represent a new strategy to sequence and analyze a single protein or DNA. The idea is to use an SPA composed of an innovative "wedding cake"shaped grating (WCG), in order to excite a Surface Plasmon Polariton (SPP) mode, and a 30-tilted Plasmonic Antenna (PA), able to compress adiabatically the SPP until the tip. The Plasmonic device is placed inside an electrical contact that could be used to unfold protein molecules or DNA. A bio-functionalized AFM tip can be used to fish a single biological element and for alignment with the SPA. Then the unfolded element could be scanned close to the PA and a Tip Enhanced Raman Signal (TERS) can be recorded from the biomolecule. The spatial resolution is limited by the size of the radius of curvature of the antenna, which in this work is about 15 nm, while the vertical scanning is controlled by the piezoelectric of the AFM set up. In this work we demonstrate the possibility to fabricate this innovative plasmonic device and we report FDTD simulations of the innovative WCG. The FDTD simulations show the generation of a plasmonic mode that, coupled with the antenna, give rise to an adiabatic compression which produce an increase of the electric field of about 40 times. © 2013 Elsevier B.V. All rights reserved.

  4. Effects of using mobile device-based academic electronic medical records for clinical practicum by undergraduate nursing students: A quasi-experimental study.

    Science.gov (United States)

    Choi, Mona; Lee, HyeongSuk; Park, Joon Ho

    2018-02-01

    The academic electronic medical record (AEMR) system is applied with the expectation that nursing students will be able to attain competence in healthcare decision-making and nursing informatics competencies. However, there is insufficient evidence regarding the advantage of applying mobile devices to clinical practicum. This study aimed to examine the effect of an experiment that introduced a mobile AEMR application for undergraduate nursing students in their practicum. A quasi-experimental design was used. The subjects were 75 third-year nursing students enrolled in clinical practicum and were divided into an experimental (practicum with AEMR) and a control (conventional practicum) group. Nursing informatics competencies, critical thinking disposition, and satisfaction with clinical practicum were measured before and after the clinical practicum for each group. The usability of the AEMR application was also examined for the experimental group after the experiment. After the experiment, the experimental group showed a significant increase in the informatics knowledge domain of nursing informatics competencies in the post-test. The difference in critical thinking between the experimental and control groups was not statistically significant. Regarding satisfaction with the clinical practicum, the experimental group exhibited a significantly higher level of satisfaction in "preparation of a diagnostic test or laboratory test and understanding of the results" and "nursing intervention and documentation" than the control group. Students who participated in the practicum using the AEMR application considered it useful. The AEMR application was an effective educational method for practicing the immediate documentation of students' observations and interventions and was available at the patients' bedsides. To improve critical thinking, it is necessary to apply a variety of approaches when solving clinical problems. Copyright © 2017 Elsevier Ltd. All rights reserved.

  5. Experimental Results of Network-Assisted Interference Suppression Scheme Using Adaptive Beam-Tilt Switching

    Directory of Open Access Journals (Sweden)

    Tomoki Murakami

    2017-01-01

    Full Text Available This paper introduces a network-assisted interference suppression scheme using beam-tilt switching per frame for wireless local area network systems and its effectiveness in an actual indoor environment. In the proposed scheme, two access points simultaneously transmit to their own desired station by adjusting angle of beam-tilt including transmit power assisted from network server for the improvement of system throughput. In the conventional researches, it is widely known that beam-tilt is effective for ICI suppression in the outdoor scenario. However, the indoor effectiveness of beam-tilt for ICI suppression has not yet been indicated from the experimental evaluation. Thus, this paper indicates the effectiveness of the proposed scheme by analyzing multiple-input multiple-output channel matrices from experimental measurements in an office environment. The experimental results clearly show that the proposed scheme offers higher system throughput than the conventional scheme using just transmit power control.

  6. Accelerated life-test methods and results for implantable electronic devices with adhesive encapsulation.

    Science.gov (United States)

    Huang, Xuechen; Denprasert, Petcharat May; Zhou, Li; Vest, Adriana Nicholson; Kohan, Sam; Loeb, Gerald E

    2017-09-01

    We have developed and applied new methods to estimate the functional life of miniature, implantable, wireless electronic devices that rely on non-hermetic, adhesive encapsulants such as epoxy. A comb pattern board with a high density of interdigitated electrodes (IDE) could be used to detect incipient failure from water vapor condensation. Inductive coupling of an RF magnetic field was used to provide DC bias and to detect deterioration of an encapsulated comb pattern. Diodes in the implant converted part of the received energy into DC bias on the comb pattern. The capacitance of the comb pattern forms a resonant circuit with the inductor by which the implant receives power. Any moisture affects both the resonant frequency and the Q-factor of the resonance of the circuitry, which was detected wirelessly by its effects on the coupling between two orthogonal RF coils placed around the device. Various defects were introduced into the comb pattern devices to demonstrate sensitivity to failures and to correlate these signals with visual inspection of failures. Optimized encapsulation procedures were validated in accelerated life tests of both comb patterns and a functional neuromuscular stimulator under development. Strong adhesive bonding between epoxy and electronic circuitry proved to be necessary and sufficient to predict 1 year packaging reliability of 99.97% for the neuromuscular stimulator.

  7. Implications of fusion results for a reactor: a proposed next step device-JIT

    International Nuclear Information System (INIS)

    Rebut, P.H.

    1989-01-01

    Simulations with a critical-temperature model have been made of proposed future devices (NET, ITER, JIT, etc.). These show that only machines with a current capability of ∼ 30MA have a sufficient ignition domain to cope with more realistic operating conditions (i.e. taking into account sawteeth effects, impurity dilution and semi-continuous operation). The importance of dilution and Bremsstrahlung radiation are clearly demonstrated; a mean temperature > 7keV is required for ignition. This prevents higher field, lower current devices from reaching ignition. Transient operations with monster sawteeth or H-mode allow such devices (>30MA) to reach ignition at lower density without additional heating. To investigate the problems of a controlled burning plasma for days in semi-continuous operation, the plasma of the next-step tokamak should be similar in size and performance to an energy producing reactor. The scientific and technical aims of such a machine should be to study burning plasma, test wall technology, provide a test-bed for breeding blankets and most importantly to demonstrate the potential and viability of fusion as an energy source. The main design characteristics of a Thermonuclear Furnace-JIT-dedicated to these objectives are presented. Watercooled copper magnets are used to benefit from proven technology. A single-null divertor configuration ensures helium exhaust and possibly benefits from an H-mode to reach the ignition domain. The X-point position relative to the dump plates would be swept to limit wall loading

  8. Computations for the 1:5 model of the THTR pressure vessel compared with experimental results

    International Nuclear Information System (INIS)

    Stangenberg, F.

    1972-01-01

    In this report experimental results measured at the 1:5-model of the prestressed concrete pressure vessel of the THTR-nuclear power station Schmehausen in 1971, are compared with the results of axis-symmetrical computations. Linear-elastic computations were performed as well as approximate computations for overload pressures taking into consideration the influences of the load history (prestressing, temperature, creep) and the effects of the steel components. (orig.) [de

  9. Zr-Fe-Sn Ternary System Phase Diagrams- New Experimental Results

    International Nuclear Information System (INIS)

    Nieva, N; Gomez, A; Arias, D

    2004-01-01

    New experimental results for the Zr-Fe-Sn ternary system are presented in this paper. The phases present and equilibrium relations for the 900 o C isothermal on the central zone of the Gibbs triangle are analysed. A set of ternary alloys was designed and obtained, and they were analysed by semi quantitative SEM- EDS, XRD, and metallographic samples. The resulting ternary phase diagrams are presented here (JCH)

  10. Numerical analysis of temperature field during hardfacing process and comparison with experimental results

    Directory of Open Access Journals (Sweden)

    Lazić Vukić N.

    2014-01-01

    Full Text Available The three-dimensional transient nonlinear thermal analysis of the hard facing process is performed by using the finite element method. The simulations were executed on the open source Salome platform using the open source finite element solver Code_Aster. The Gaussian double ellipsoid was selected in order to enable greater possibilities for the calculation of the moving heat source. The numerical results were compared with available experimental results.

  11. Experimental results concerning global observables from the CERN SPS heavy ion program

    International Nuclear Information System (INIS)

    Young, G.R.

    1990-06-01

    A brief overview is given of experimental results obtained during the initial operation of the heavy-ion program at the CERN SPS during the period 1986--1988. This paper confines itself to a presentation of results on so-called global observables, such as energy flow and multiplicity distributions, and on information extracted from them. Of particular interest among the latter are an estimate of the magnitude and spatial distribution of the energy density attained. 3 refs., 27 figs

  12. Experimental investigation and modelling of surface roughness and resultant cutting force in hard turning of AISI H13 Steel

    Science.gov (United States)

    Boy, M.; Yaşar, N.; Çiftçi, İ.

    2016-11-01

    In recent years, turning of hardened steels has replaced grinding for finishing operations. This process is compared to grinding operations; hard turning has higher material removal rates, the possibility of greater process flexibility, lower equipment costs, and shorter setup time. CBN or ceramic cutting tools are widely used hard part machining. For successful application of hard turning, selection of suitable cutting parameters for a given cutting tool is an important step. For this purpose, an experimental investigation was conducted to determine the effects of cutting tool edge geometry, feed rate and cutting speed on surface roughness and resultant cutting force in hard turning of AISI H13 steel with ceramic cutting tools. Machining experiments were conducted in a CNC lathe based on Taguchi experimental design (L16) in different levels of cutting parameters. In the experiments, a Kistler 9257 B, three cutting force components (Fc, Ff and Fr) piezoelectric dynamometer was used to measure cutting forces. Surface roughness measurements were performed by using a Mahrsurf PS1 device. For statistical analysis, analysis of variance has been performed and mathematical model have been developed for surface roughness and resultant cutting forces. The analysis of variance results showed that the cutting edge geometry, cutting speed and feed rate were the most significant factors on resultant cutting force while the cutting edge geometry and feed rate were the most significant factor for the surface roughness. The regression analysis was applied to predict the outcomes of the experiment. The predicted values and measured values were very close to each other. Afterwards a confirmation tests were performed to make a comparison between the predicted results and the measured results. According to the confirmation test results, measured values are within the 95% confidence interval.

  13. Design and experimental results of the 1-T Bitter Electromagnet Testing Apparatus (BETA)

    Science.gov (United States)

    Bates, E. M.; Birmingham, W. J.; Romero-Talamás, C. A.

    2018-05-01

    The Bitter Electromagnet Testing Apparatus (BETA) is a 1-Tesla (T) technical prototype of the 10 T Adjustable Long Pulsed High-Field Apparatus. BETA's final design specifications are highlighted in this paper which include electromagnetic, thermal, and stress analyses. We discuss here the design and fabrication of BETA's core, vessel, cooling, and electrical subsystems. The electrical system of BETA is composed of a scalable solid-state DC breaker circuit. Experimental results display the stable operation of BETA at 1 T. These results are compared to both analytical design and finite element calculations. Experimental results validate analytical magnet designing methods developed at the Dusty Plasma Laboratory. The theoretical steady state maxima and the limits of BETA's design are explored in this paper.

  14. A global analysis of recent experimental results: How well determined are the parton distribution functions?

    International Nuclear Information System (INIS)

    Morfin, J.G.

    1990-08-01

    Following is a brief summary of the results of an analysis of experimental data performed to extract the patron distribution functions. In contrast to other global analyses, this study investigated how the fit results depend on: Experimental Systematic Errors; Kinematic Cuts on the Analyzed Data and Choice of Initial Functional Forms, with a prime goal being a close look at the range of low-x behavior allowed by data. This is crucial for predictions for the SSC/LHC, HERA, and even at Tevatron Collider energies. Since all details can be found in the just released Fermilab preprint Parton Distributions from a Global QCD Analysis of Deep Inelastic Scattering and Lepton-Pair Production by J. G. M. and Wu-Ki Tung, this summary will be only a brief outline of major results. 11 refs., 13 figs

  15. Processing considerations with plasma-based ion implantation of polymers: theoretical aspects, limitations, and experimental results

    International Nuclear Information System (INIS)

    Lacoste, A.; Pelletier, J.

    2003-01-01

    Processing of polymers using plasma-based ion implantation techniques (PBII) has general implications in terms of plasma specifications and pulse characteristics. In particular, the different aspects of the processing of polymer layers are discussed as functions of plasma density, pulse duration, and layer characteristics (thickness and permittivity). Clearly, severe limitations (true implantation energy, arcing) may appear for high-density plasmas as well as for long pulse durations, when processing polymer layers with thickness in the mm range. A review of the experimental results of ion implantation in polymeric materials via PBII processing is presented. The experimental results demonstrate the possibility of processing polymer layers with the PBII technique, but with severe limitations resulting from the process itself

  16. Geometrical modification transfer between specific meshes of each coupled physical codes. Application to the Jules Horowitz research reactor experimental devices

    International Nuclear Information System (INIS)

    Duplex, B.

    2011-01-01

    The CEA develops and uses scientific software, called physical codes, in various physical disciplines to optimize installation and experimentation costs. During a study, several physical phenomena interact, so a code coupling and some data exchanges between different physical codes are required. Each physical code computes on a particular geometry, usually represented by a mesh composed of thousands to millions of elements. This PhD Thesis focuses on the geometrical modification transfer between specific meshes of each coupled physical code. First, it presents a physical code coupling method where deformations are computed by one of these codes. Next, it discusses the establishment of a model, common to different physical codes, grouping all the shared data. Finally, it covers the deformation transfers between meshes of the same geometry or adjacent geometries. Geometrical modifications are discrete data because they are based on a mesh. In order to permit every code to access deformations and to transfer them, a continuous representation is computed. Two functions are developed, one with a global support, and the other with a local support. Both functions combine a simplification method and a radial basis function network. A whole use case is dedicated to the Jules Horowitz reactor. The effect of differential dilatations on experimental device cooling is studied. (author) [fr

  17. Analysis and experimental results of frequency splitting of underwater wireless power transfer

    Directory of Open Access Journals (Sweden)

    Wangqiang Niu

    2017-06-01

    Full Text Available Underwater wireless power transfer (UWPT is an important technique to power underwater devices while its frequency splitting phenomena are not fully elucidated. In this study, frequency splitting phenomena of a symmetrical planar two-coil wireless power transfer (WPT system resonated at 90 kHz are investigated in seawater and freshwater. A concise frequency splitting analysis of this WPT system in air based on circuit model is given first and then experimental data are reported to show there is little difference between power transfer in air, freshwater and seawater in the range of 40–140 kHz of this WPT system. Consequently, the frequency splitting analysis and observations in air are also applicable in freshwater and seawater. It is found a V-type frequency splitting pattern exists in this WPT system under seawater and freshwater. Frequency shift is observed in this UWPT system in overcoupled region, and no frequency shift is observed in undercoupled region. In undercoupled region, in the low frequency zone of 40–90 kHz the load voltage characteristics in three media are identical; in the high-frequency zone of 90–140 kHz, the load voltage in air is slightly larger than those in freshwater and seawater.

  18. Radiation Test Results on COTS and non-COTS Electronic Devices for NASA-JSC Space Flight Projects

    Science.gov (United States)

    Allums, Kimberly K.; O'Neill, P. M.; Reddell, B. D.; Nguyen, K. V.; Bailey, C. R.

    2012-01-01

    This presentation reports the results of recent proton and heavy ion Single Event Effect (SEE) testing on a variety of COTS and non-COTs electronic devices and assemblies tested for the Space Shuttle, International Space Station (ISS) and Multi-Purpose Crew Vehicle (MPCV).

  19. Axial and radial preliminary results of the neutron radiation from miniature plasma focus devices

    Energy Technology Data Exchange (ETDEWEB)

    Moreno, J.; Silva, P.; Soto, L. [Comision Chilena de Energia Nuclear, Santiago (Chile)

    2004-07-01

    As first step of a program to design a repetitive pulsed neutron generator for applications, two miniature plasma foci have been designed and constructed at the Chilean commission of nuclear energy. The devices operate at an energy level of the order of tens of joules (PF-50 J, 160 nF capacitor bank, 20-35 kV, 32-100 J, {approx} 150 ns time to peak current) and hundred of joules (PF-400 J, 880 nF, 20-35 kV, 176-539 J, {approx} 300 ns time to peak current). Neutron emission has been obtained in both devices operating in deuterium. A specific technique was necessary to develop in order to detect neutron pulsed of 10{sup 4} neutrons per shot. The maximum total neutron yield measured was of the order of 10{sup 6} and 10{sup 4} neutrons per shot in the PF-400 J and PF-50 J respectively. Axial and radial measurements of the neutron emission are presented and the anisotropy is evaluated in this work. The neutrons are measured by pairs of silver activation counters, {sup 3}He detectors and scintillator-photomultiplier detectors. (authors)

  20. [Early results with a monorail-stent-balloon device for endovascular treatment of renal artery stenosis].

    Science.gov (United States)

    Müller-Hülsbeck, S; Jahnke, T; Grimm, J; Behm, C; Hilbert, C; Frahm, C; Biederer, J; Brossmann, J; Heller, M

    2002-03-01

    To evaluate the technical feasibility of a new monorail-stent-balloon device for treatment of renal artery stenosis (RAS). During a study period of 18 months, 38 patients with proven RAS in 41 cases (hypertension n = 36, renal insufficiency n = 13) and indication for stenting (calicified ostial lesions n = 35, insufficient PTA n = 4, dissection n = 2) were enrolled into this prospective evaluation. Pre-mounted stents (Rx-Herculink(TM) 5 mm = 13, 6 mm = 34, 7 mm = 1) were implanted a transfemoral (n = 35) or transbrachial approach (n = 6). Mean grade and lengths of stenosis measured were 88 % plus minus 10 and 9 mm plus minus 5. Renal stent implantation was technically successful in all cases (100 %). In 7 cases a second stent had to be implanted to cover the entire lesion. The transstenotic pressure drop decreased from 88 mmHg plus minus 10 before to 1 mmHg plus minus 1.8 after the procedure. Remaining stenosis measured 0.7 % plus minus 4.2. Serum creatine levels decreased from 1.9 mm/dl to 1.5 mg/dl (n. s.), blood pressure decreased from 178/94 mmHg to 148/79 mmHg (p monorail-stend-balloon device a technically easy, secure and exact renal stent placement is guaranteed, patency rates are similar to those described in the current literature.

  1. Transcatheter device closure of ruptured sinus of Valsalva: Immediate results and short term follow up

    Directory of Open Access Journals (Sweden)

    Sen Supratim

    2009-01-01

    Full Text Available This is a retrospective, observational study comprising of eight patients with isolated rupture of the sinus of Valsalva (RSOV who underwent transcatheter device closure. The mean age of presentation was 32.8 ± 10.0 years. New York Heart Association (NYHA class at the time of presentation was II (six patients and III (two patients. The RSOVs were all closed using a patent ductus arteriosus device. The mean procedural time was 42.3 ± 5.4 minutes, while the fluoroscopic time was 24.5 ± 6.9 minutes. All had complete closure of the shunt. The average hospital stay was 2.9 ± 1.1 days. There were no major complications. The patients were followed up for a mean of 11.3 ± 4.1 months. At the time of the last follow up all the patients were in NYHA class I. We conclude that in the short term, transcatheter closure of isolated RSOV is a viable alternative to surgical repair.

  2. Validation of thermohydraulic codes by comparison of experimental results with computer simulations

    International Nuclear Information System (INIS)

    Madeira, A.A.; Galetti, M.R.S.; Pontedeiro, A.C.

    1989-01-01

    The results obtained by simulation of three cases from CANON depressurization experience, using the TRAC-PF1 computer code, version 7.6, implanted in the VAX-11/750 computer of Brazilian CNEN, are presented. The CANON experience was chosen as first standard problem in thermo-hydraulic to be discussed at ENFIR for comparing results from different computer codes with results obtained experimentally. The ability of TRAC-PF1 code to prevent the depressurization phase of a loss of primary collant accident in pressurized water reactors is evaluated. (M.C.K.) [pt

  3. Characteristics of prompt fission gamma-ray emission - Experimental results and predictions

    International Nuclear Information System (INIS)

    Oberstedt, Andreas; Billnert, Robert; Oberstedt, Stephan

    2014-01-01

    Systematics from 2001, describing prompt fission gamma-ray spectra (PFGS) characteristics as function of mass and atomic number of the fissioning system, has been revisited and parameters have been revised based on recent experimental results. Although originally expressed for spontaneous and thermal neutron-induced fission, validity for fast neutrons was assumed and applied to predict PFGS characteristics for the reaction n + 238 U up to incident neutron energies of E n = 20 MeV. The results from this work are in good agreement with corresponding results from both model calculations and experiments. (authors)

  4. Room temperature thin foil SLIM-cut using an epoxy paste: experimental versus theoretical results

    International Nuclear Information System (INIS)

    Bellanger, Pierre; Serra, Joao; Bouchard, Pierre-Olivier; Bernacki, Marc

    2015-01-01

    The stress induced lift-off method (SLIM) -cut technique allows the detachment of thin silicon foils using a stress inducing layer. In this work, results of SLIM-cut foils obtained using an epoxy stress inducing layer at room temperature are presented. Numerical analyses were performed in order to study and ascertain the important experimental parameters. The experimental and simulation results are in good agreement. Indeed, large area (5 × 5 cm 2 ) foils were successfully detached at room temperature using an epoxy thickness of 900 μm and a curing temperature of 150 °C. Moreover, three foils (5 × 3 cm 2 ) with thickness 135, 121 and 110 μm were detached from the same monocrystalline substrate. Effective minority carrier lifetimes of 46, 25 and 20 μs were measured using quasi-steady-state photoconductance technique in these foils after iodine ethanol surface passivation. (paper)

  5. Performance limits of direct cryogenically cooled silicon monochromators - experimental results at the APS

    International Nuclear Information System (INIS)

    Lee, W.-K.; Fernandez, P.; Mills, D.M.

    2000-01-01

    The successful use of cryogenically cooled silicon monochromators at third-generation synchrotron facilities is well documented. At the Advanced Photon Source (APS) it has been shown that, at 100 mA operation with the standard APS undulator A, the cryogenically cooled silicon monochromator performs very well with minimal (<2 arcsec) or no observable thermal distortions. However, to date there has not been any systematic experimental study on the performance limits of this approach. This paper presents experimental results on the performance limits of these directly cooled crystals. The results show that if the beam is limited to the size of the radiation central cone then, at the APS, the crystal will still perform well at twice the present 100 mA single 2.4 m-long 3.3 cm-period undulator heat load. However, the performance would degrade rapidly if a much larger incident white-beam size is utilized

  6. Adsorption of methanol molecule on graphene: Experimental results and first-principles calculations

    Science.gov (United States)

    Zhao, X. W.; Tian, Y. L.; Yue, W. W.; Chen, M. N.; Hu, G. C.; Ren, J. F.; Yuan, X. B.

    2018-04-01

    Adsorption properties of methanol molecule on graphene surface are studied both theoretically and experimentally. The adsorption geometrical structures, adsorption energies, band structures, density of states and the effective masses are obtained by means of first-principles calculations. It is found that the electronic characteristics and conductivity of graphene are sensitive to the methanol molecule adsorption. After adsorption of methanol molecule, bandgap appears. With the increasing of the adsorption distance, the bandgap, adsorption energy and effective mass of the adsorption system decreased, hence the resistivity of the system decreases gradually, these results are consistent with the experimental results. All these calculations and experiments indicate that the graphene-based sensors have a wide range of applications in detecting particular molecules.

  7. Critical experiments carried out with a homogeneous plutonium solution. Experimental results. Theoretical interpretations

    International Nuclear Information System (INIS)

    Bouly, J.C.; Caizergues, R.; Deilgat, E.; Houelle, M.; Lecorche, P.

    1967-01-01

    This report groups together a series of experimental and theoretical studies on cylinders and plates of solution tried out at the Valduc Centre. a) Comparison of the theoretical and experimental results obtained on critical heights of solutions. b) Study of the effect of nitrogen, introduced in the form of the ion NO 3- , on the reactivity of fissile media. c) Study of the effect of 240 94 Pu on the reactivity of these media. d) Study of the influence of the dimensions of the inner cavity of annular cylinders, as well as of the influence of the moderator which may be introduced. Simple results were obtained which were easy to apply. An extrapolation to other geometries is made. (authors) [fr

  8. Advanced Supersonic Nozzle Concepts: Experimental Flow Visualization Results Paired With LES

    Science.gov (United States)

    Berry, Matthew; Magstadt, Andrew; Stack, Cory; Gaitonde, Datta; Glauser, Mark; Syracuse University Team; The Ohio State University Team

    2015-11-01

    Advanced supersonic nozzle concepts are currently under investigation, utilizing multiple bypass streams and airframe integration to bolster performance and efficiency. This work focuses on the parametric study of a supersonic, multi-stream jet with aft deck. The single plane of symmetry, rectangular nozzle, displays very complex and unique flow characteristics. Flow visualization techniques in the form of PIV and schlieren capture flow features at various deck lengths and Mach numbers. LES is compared to the experimental results to both validate the computational model and identify limitations of the simulation. By comparing experimental results to LES, this study will help create a foundation of knowledge for advanced nozzle designs in future aircraft. SBIR Phase II with Spectral Energies, LLC under direction of Barry Kiel.

  9. Experimental study of potential structure in a spherical IEC fusion device

    International Nuclear Information System (INIS)

    Gu, Y.; Miley, G.H.

    2000-01-01

    The spherical inertial-electrostatic confinement (SIEC) concept is designed to focus and accelerate ions and electrons radially inward towards the center of a negatively biased, highly transparent spherical grid. The converging ions create a high-density plasma core where a high fusion rate occurs. In addition, under proper conditions, the ion and electron flows create a space-charge induced double potential well (a negative potential well nested inside a positive potential well). This structure traps high-energy ions within the virtual anode created by the double potential, providing a high fusion density in the trap volume. The present experiment was designed to verify double potential well formation and trapping by a measurement of the radial birth profile of energetic (3-MeV) protons produced by D-D fusion reactions in a deuterium discharge. This experiment was designed to operate at high perveance (0.4 to 1.4 mA/kV 3/2 ), where formation of a double well is predicted theoretically. Additional steps to aid well formation included: use of the unique Star mode of operation to obtain ion beam focusing down to approximately 1.6 H the ballistic limit and the incorporation of a second electrically floating grid (in addition to the focusing/accelerating cathode grid) to reduce the ion radial energy spread to 0.34 mA/kV 3/2 . As the perveance increased, the depth of the double well also increased. At the maximum perveance studied, 1.38 mA/kV 3/2 (corresponding to 80 mA and 15 kV), the negative potential well depth, corresponding to the measured proton-rate density, was estimated to be 22%--27% of the applied cathode voltage. This represents the first conclusive demonstration of double well formation in an SIEC, since prior measurements by other researchers typically yielded marginal or negative results

  10. Search for muonium to antimuonium conversion: Overview and recent experimental results

    International Nuclear Information System (INIS)

    Reiner Schaefer, H.

    1988-01-01

    The motivation for an experimental search for muonium to antimuonium conversion is briefly discussed. Results of measurements on limits for the strength of the coupling constant involved in this interaction are summarized with emphasis on the recently completed search, LAMPF E985. Plans are presented for an upcoming next generation experiment, LAMF E1073, which aims at an improvement in the sensitivity by more than two orders of magnitude

  11. Verification of simulation model with COBRA-IIIP code by confrontment of experimental results

    International Nuclear Information System (INIS)

    Silva Galetti, M.R. da; Pontedeiro, A.C.; Oliveira Barroso, A.C. de

    1985-01-01

    It is presented an evaluation of the COBRA IIIP/MIT code (of thermal hydraulic analysis by subchannels), comparing their results with experimental data obtained in stationary and transient regimes. It was done a study to calculate the spatial and temporal critical heat flux. It is presented a sensitivity study of simulation model related to the turbulent mixture and the number of axial intervals. (M.C.K.) [pt

  12. FIRST EXPERIMENTAL RESULTS FROM DEGAS, THE QUANTUM LIMITED BRIGHTNESS ELECTRON SOURCE

    International Nuclear Information System (INIS)

    Zolotorev, Max S.; Commins, Eugene D.; Oneill, James; Sannibale, Fernando; Tremsin, Anton; Wan, Weishi

    2008-01-01

    The construction of DEGAS (DEGenerate Advanced Source), a proof of principle for a quantum limited brightness electron source, has been completed at the Lawrence Berkeley National Laboratory. The commissioning and the characterization of this source, designed to generate coherent single electron 'bunches' with brightness approaching the quantum limit at a repetition rate of few MHz, has been started. In this paper the first experimental results are described

  13. Variable Entry Biased Paracentric Hemispherical Deflector: Experimental results on energy resolution for different entry positions

    Science.gov (United States)

    Dogan, Mevlut; Ulu, Melike; Gennerakis, Giannis; Zouros, Theo J. M.

    2014-04-01

    A new hemispherical deflector analyzer (HDA) which is designed for electron energy analysis in atomic collisions has been constructed and tested. Using the crossed beam technique at the electron spectrometer, test measurements were performed for electron beam (200 eV) - Helium atoms interactions. These first experimental results show that the paracentric entries give almost twice as good resolution as that for the conventional entry. Supporting simulations of the entire lens+HDA spectrometer are found in relatively good agreement with experiment.

  14. Defining Dynamic Characteristics of Multilink Pendulum System with Comparison of the Calculated and Experimental Results

    Directory of Open Access Journals (Sweden)

    V. A. Gribkov

    2015-01-01

    Full Text Available We consider the multilink pendulum system consisting of six physical pendulums. A pendulum (carrier has inertia parameters, which significantly exceed the remaining (carried ones placed on the carrier. In addition to the system under analysis, in particular, the paper presents a design scheme for a two-stage liquid fuel rocket using pendulums as the analogues of fluctuating fuel. Pendulum models also find application to solve problems of stabilization of space tether systems. The objective of the study is to determine dynamic characteristics of the said sixmembered pendulum system, as well as to identify specific dynamic properties inherent in objects of this kind. Dynamic characteristics of the system are determined by calculations. A physical model of the pendulum allowed us to compare the calculated and experimental results. To conduct the frequency tests of the pendulum model three pilot units have been created. The first two units turned out to be inappropriate for fulfilling the experimental tasks for various reasons. The third unit enabled us to obtain desirable experimental results. The "calculation–experiment” discrepancy on the natural frequencies of the pendulum model for the majority of frequencies was less than 5%. We analyzed the dynamic features of multilink pendulum systems "carried by the carrier unit links". The analysis results are applicable to the above-noted object classes of rocket and space technology.

  15. Experimental results of a direct air-cooled ammonia–lithium nitrate absorption refrigeration system

    International Nuclear Information System (INIS)

    Llamas-Guillén, S.U.; Cuevas, R.; Best, R.; Gómez, V.H.

    2014-01-01

    Absorption thermal cooling systems driven by renewable energy are a viable option in order to reduce fossil fuel consumption and the associated emissions. This work shows the results of an air cooled absorption cooling prototype working with an ammonia–lithium nitrate mixture at high ambient temperatures. An absorption refrigeration system was designed and built. The prototype is a one stage ammonia–lithium nitrate air cooled chiller. The experimental system was instrumented to evaluate each component. This paper shows the operation conditions in the experimental unit as well as some of the heat loads encountered at different operating conditions. The system was operated successfully at ambient temperatures in the range of 25–35 °C. A series of test showed that even at ambient temperatures it can be operated at evaporator temperatures below 10 °C producing chilled water for air conditioning applications such as radiative cooling panels. The system proved to stabilize very quickly and no risk of crystallization was encountered so the first results are promising in order to continue with the development of a more advanced prototype. - Highlights: •Experimental results of a direct air-cooled ammonia–lithium nitrate system. •The prototype is a one stage ammonia–lithium nitrate air cooled chiller. •The absorption system was operated successfully at ambient temperatures. •Cooling loads of 4.5 kW were reached in the chilled water side

  16. First experimental result of toroidal confinement of non-neutral plasma on Proto-RT

    International Nuclear Information System (INIS)

    Himura, H.; Yoshida, Z.; Morikawa, J.

    1999-01-01

    Recently, an internal-ring device named Proto-RT (Prototype Ring Trap) was constructed at University of Tokyo, and experiments on the device have been just initiated. The goal of Proto-RT is to explore an innovative way which has a possibility to attain a plasma equilibrium with extremely high-β (β>1) in a toroidal geometry using non-neutral condition. At the first series of the experiments, pure electron plasma (n e ∼10 12 m -3 ) is successfully confined inside a separatrix. No disruption is so far observed. The confinement time of the electron plasma is the order of 1 sec. A shear effect of magnetic fields seems to result in longer confinement. The non-neutrality of Δn e ∼10 12 m -3 is already beyond the value required to produce an enough self-electric field E in plasma, causing a strong ExB flow thoroughly all over the plasma where the hydrodynamic pressure of the flow is predicted to balance with the thermal pressure of the plasma. (author)

  17. Experimental results for a 1.5 MW, 110 GHz gyrotron oscillator with reduced mode competition

    Science.gov (United States)

    Choi, E. M.; Marchewka, C. D.; Mastovsky, I.; Sirigiri, J. R.; Shapiro, M. A.; Temkin, R. J.

    2006-02-01

    A new result from a 110GHz gyrotron at MIT is reported with an output power of 1.67MW and an efficiency of 42% when operated at 97kV and 41A for 3μs pulses in the TE22,6 mode. These results are a major improvement over results obtained with an earlier cavity design, which produced 1.43MW of power at 37% efficiency. These new results were obtained using a cavity with a reduced output taper angle and a lower ohmic loss when compared with the earlier cavity. The improved operation is shown experimentally to be the result of reduced mode competition from the nearby TE19,7 mode. The reduced mode competition agrees well with an analysis of the startup scenario based on starting current simulations. The present results should prove useful in planning long pulse and CW versions of the 110GHz gyrotron.

  18. Experimental results for a 1.5 MW, 110 GHz gyrotron oscillator with reduced mode competition

    International Nuclear Information System (INIS)

    Choi, E.M.; Marchewka, C.D.; Mastovsky, I.; Sirigiri, J.R.; Shapiro, M.A.; Temkin, R.J.

    2006-01-01

    A new result from a 110 GHz gyrotron at MIT is reported with an output power of 1.67 MW and an efficiency of 42% when operated at 97 kV and 41 A for 3 μs pulses in the TE 22,6 mode. These results are a major improvement over results obtained with an earlier cavity design, which produced 1.43 MW of power at 37% efficiency. These new results were obtained using a cavity with a reduced output taper angle and a lower ohmic loss when compared with the earlier cavity. The improved operation is shown experimentally to be the result of reduced mode competition from the nearby TE 19,7 mode. The reduced mode competition agrees well with an analysis of the startup scenario based on starting current simulations. The present results should prove useful in planning long pulse and CW versions of the 110 GHz gyrotron

  19. Thermodynamic properties of 1-naphthol: Mutual validation of experimental and computational results

    International Nuclear Information System (INIS)

    Chirico, Robert D.; Steele, William V.; Kazakov, Andrei F.

    2015-01-01

    Highlights: • Heat capacities were measured for the temperature range 5 K to 445 K. • Vapor pressures were measured for the temperature range 370 K to 570 K. • Computed and derived properties for ideal gas entropies are in excellent accord. • The enthalpy of combustion was measured and shown to be consistent with reliable literature values. • Thermodynamic consistency analysis revealed anomalous literature data. - Abstract: Thermodynamic properties for 1-naphthol (Chemical Abstracts registry number [90-15-3]) in the ideal-gas state are reported based on both experimental and computational methods. Measured properties included the triple-point temperature, enthalpy of fusion, and heat capacities for the crystal and liquid phases by adiabatic calorimetry; vapor pressures by inclined-piston manometry and comparative ebulliometry; and the enthalpy of combustion of the crystal phase by oxygen bomb calorimetry. Critical properties were estimated. Entropies for the ideal-gas state were derived from the experimental studies for the temperature range 298.15 ⩽ T/K ⩽ 600, and independent statistical calculations were performed based on molecular geometry optimization and vibrational frequencies calculated at the B3LYP/6-31+G(d,p) level of theory. The mutual validation of the independent experimental and computed results is achieved with a scaling factor of 0.975 applied to the calculated vibrational frequencies. This same scaling factor was successfully applied in the analysis of results for other polycyclic molecules, as described in a series of recent articles by this research group. This article reports the first extension of this approach to a hydroxy-aromatic compound. All experimental results are compared with property values reported in the literature. Thermodynamic consistency between properties is used to show that several studies in the literature are erroneous. The enthalpy of combustion for 1-naphthol was also measured in this research, and excellent

  20. A novel telemonitoring device for improving diabetes control: protocol and results from a randomized clinical trial.

    Science.gov (United States)

    Pressman, Alice R; Kinoshita, Linda; Kirk, Susan; Barbosa, Gina Monraz; Chou, Cathy; Minkoff, Jerome

    2014-02-01

    Telemedicine is one approach to managing patients with chronic illness. Several telephone-based monitoring studies of diabetes patients have shown improved glycosylated hemoglobin (HbA1c), blood pressure (BP), and low-density lipoprotein (LDL) levels. The purpose of this study was to evaluate an investigational in-home telemetry device for improving glucose and BP control over 6 months for patients with type 2 diabetes. The device was used to transmit weekly blood glucose, weight, and BP readings to a diabetes care manager. We conducted a two-arm, parallel-comparison, single-blind, randomized controlled trial among Kaiser Permanente Northern California members 18-75 years old with type 2 diabetes mellitus and entry HbA1c levels between 7.5% and 10.0%. Participants were randomly assigned to either the telemonitoring arm or the usual care arm. We observed very small, nonsignificant changes in fructosamine (telemonitoring, -54.9 μmol; usual care, -59.4 μmol) and systolic BP (telemonitoring, -6.3 mm Hg; usual care, -3.2 mm Hg) from baseline to 6 weeks in both groups. At 6 months, we observed no significant intergroup differences in change from baseline for HbA1c, fructosamine, or self-efficacy. However, LDL cholesterol in the telemonitoring arm decreased more than in the usual care arm (-17.1 mg/dL versus -5.4 mg/dL; P=0.045). Although HbA1c improved significantly over 6 months in both groups, the difference in improvement between the groups was not significant. This lack of significance may be due to the relatively healthy status of the volunteers in our study and to the high level of care provided by the care managers in the Santa Rosa, CA clinic. Further study in subgroups of less healthy diabetes patients is recommended.

  1. RESULTS OF THE SURVEY CONDUCTED AMONG OPHTHALMOLOGISTS ON THE ISSUE OF EQUIPMENT OF MEDICAL INSTITUTIONS WITH OPHTHALMOLOGY DEVICES

    Directory of Open Access Journals (Sweden)

    S. V. Seraphimov

    2017-01-01

    Full Text Available Introduction. The problem of limited accessibility and quality of ophthalmic medical care remains one of the leading ones in the national healthcare. This article presents results of the survey conducted among ophthalmologists about the effect of large-scale equipment of all medical institutions in the Leningrad Region with modern ophthalmologic devices over the recent years.Objective is to determine the contribution of the health care modernization program to equipping the medical institutions of the Leningrad Region with modern ophthalmologic medical devices, and to identify the main areas for improving the ophthalmologic care for residents of the Leningrad region with cataracts.Materials and methods. According to a specially developed questionnaire, 105 ophthalmologists from the Leningrad Region were interviewed. The survey was conducted among physicians working both in out-patient medical facilities and in medical facilities with in-patient modalities.Results. The results of the study confirmed positive changes that occurred in recent years as a result of equipping medical institutions with modern medical devices. Almost two-thirds (59.9% of respondents noted that equipping with modern medical devices had a significant impact on the quality of the medical and diagnostic measures carried out in healthcare facilities of the region.Conclusions. The equipment had a significant impact on the diagnosis and treatment of all kinds of diseases of the eye and its appendages, especially such eye disease which is so common among the population of the Leningrad Region as cataracts (75.0 per 100 ophthalmologists surveyed. At the same time, in spite of these efforts, the standard for equipping ophthalmologic departments in individual medical institutions has not been fully provided. Only every fifth (20.9% ophthalmologist noted during the survey that the list of available ophthalmic devices was sufficient, and that they all worked properly.

  2. Comparison of numerical and experimental results of the flow in the U9 Kaplan turbine model

    Science.gov (United States)

    Petit, O.; Mulu, B.; Nilsson, H.; Cervantes, M.

    2010-08-01

    The present work compares simulations made using the OpenFOAM CFD code with experimental measurements of the flow in the U9 Kaplan turbine model. Comparisons of the velocity profiles in the spiral casing and in the draft tube are presented. The U9 Kaplan turbine prototype located in Porjus and its model, located in Älvkarleby, Sweden, have curved inlet pipes that lead the flow to the spiral casing. Nowadays, this curved pipe and its effect on the flow in the turbine is not taken into account when numerical simulations are performed at design stage. To study the impact of the inlet pipe curvature on the flow in the turbine, and to get a better overview of the flow of the whole system, measurements were made on the 1:3.1 model of the U9 turbine. Previously published measurements were taken at the inlet of the spiral casing and just before the guide vanes, using the laser Doppler anemometry (LDA) technique. In the draft tube, a number of velocity profiles were measured using the LDA techniques. The present work extends the experimental investigation with a horizontal section at the inlet of the draft tube. The experimental results are used to specify the inlet boundary condition for the numerical simulations in the draft tube, and to validate the computational results in both the spiral casing and the draft tube. The numerical simulations were realized using the standard k-e model and a block-structured hexahedral wall function mesh.

  3. Comparison of numerical and experimental results of the flow in the U9 Kaplan turbine model

    International Nuclear Information System (INIS)

    Petit, O; Nilsson, H; Mulu, B; Cervantes, M

    2010-01-01

    The present work compares simulations made using the OpenFOAM CFD code with experimental measurements of the flow in the U9 Kaplan turbine model. Comparisons of the velocity profiles in the spiral casing and in the draft tube are presented. The U9 Kaplan turbine prototype located in Porjus and its model, located in Alvkarleby, Sweden, have curved inlet pipes that lead the flow to the spiral casing. Nowadays, this curved pipe and its effect on the flow in the turbine is not taken into account when numerical simulations are performed at design stage. To study the impact of the inlet pipe curvature on the flow in the turbine, and to get a better overview of the flow of the whole system, measurements were made on the 1:3.1 model of the U9 turbine. Previously published measurements were taken at the inlet of the spiral casing and just before the guide vanes, using the laser Doppler anemometry (LDA) technique. In the draft tube, a number of velocity profiles were measured using the LDA techniques. The present work extends the experimental investigation with a horizontal section at the inlet of the draft tube. The experimental results are used to specify the inlet boundary condition for the numerical simulations in the draft tube, and to validate the computational results in both the spiral casing and the draft tube. The numerical simulations were realized using the standard k-e model and a block-structured hexahedral wall function mesh.

  4. Main Experimental Results of ISTC-1606 for Recycling and Transmutation in Molten Salt Systems

    International Nuclear Information System (INIS)

    Ignatiev, Victor; Feynberg, Olga; Merzlyakov, Aleksandr; Surenkov, Aleksandr; Subbotin, Vladimir; Zakirov, Raul; Toropov, Andrey; Panov, Aleksandr; Afonichkin, Valery

    2008-01-01

    To examine and demonstrate the feasibility of molten salt reactors (MSR) to reduce long lived waste toxicity and to produce efficiently electricity in closed fuel cycle, some national and international studies were initiated last years. In this paper main focus is placed on experimental evaluation of single stream Molten Salt Actinide Recycler and Transmuter (MOSART) system fuelled with different compositions of plutonium plus minor actinide trifluoride (AnF 3 ) from LWR spent nuclear fuel without U-Th support. This paper summarizes main experimental results of ISTC-1606 related to physical and chemical properties of fuel salt, container materials for fuel circuit, and fuel salt clean up of MOSART system. As result of ISTC-1606 studies claim is made, that the 7 Li,Na,Be/F and 7 Li,Be/F solvents selected for primary system appear to resolve main reactor physics, thermal hydraulics, materials compatibility, fuel salt clean up and safety problems as applied to the MOSART concept development. The created experimental facilities and the database on properties of fuel salt mixtures and container materials are used for a choice and improvement fuel salts and coolants for new applications of this high temperature technology for sustainable nuclear power development. (authors)

  5. SiO2-Ta2O5 sputtering yields: simulated and experimental results

    International Nuclear Information System (INIS)

    Vireton, E.; Ganau, P.; Mackowski, J.M.; Michel, C.; Pinard, L.; Remillieux, A.

    1994-09-01

    To improve mirrors coating, we have modeled sputtering of binary oxide targets using TRIM code. First, we have proposed a method to calculate TRIM input parameters using on the one hand thermodynamic cycle and on the other hand Malherbe's results. Secondly, an iterative processing has provided for oxide steady targets caused by ionic bombardment. Thirdly, we have exposed a model to get experimental sputtering yields. Fourthly, for (Ar - SiO 2 ) pair, we have determined that steady target is a silica one. A good agreement between simulated and experimental yields versus ion incident angle has been found. For (Ar - Ta 2 O 5 ) pair, we have to introduce preferential sputtering concept to explain discrepancy between simulation and experiment. In this case, steady target is tantalum monoxide. For (Ar - Ta(+O 2 ) pair, tantalum sputtered by argon ions in reactive oxygen atmosphere, we have to take into account new concept of oxidation stimulated by ion beam. We have supposed that tantalum target becomes a Ta 2 O 5 one in reactive oxygen atmosphere. Then, following mechanism is similar to previous pair. We have obtained steady target of tantalum monoxide too. Comparison between simulated and experimental sputtering yields versus ion incident angle has given very good agreement. By simulation, we have found that tantalum monoxide target has at least 15 angstrom thickness. Those results are compatible with Malherbe's and Taglauer's ones. (authors)

  6. Comparison of numerical and experimental results of the flow in the U9 Kaplan turbine model

    Energy Technology Data Exchange (ETDEWEB)

    Petit, O; Nilsson, H [Division of Fluid Mechanics, Chalmers University of Technology, Hoersalsvaegen 7A, SE-41296 Goeteborg (Sweden); Mulu, B; Cervantes, M, E-mail: olivierp@chalmers.s [Division of Fluid Mechanics, Luleaa University of Technology, SE-971 87 Luleaa (Sweden)

    2010-08-15

    The present work compares simulations made using the OpenFOAM CFD code with experimental measurements of the flow in the U9 Kaplan turbine model. Comparisons of the velocity profiles in the spiral casing and in the draft tube are presented. The U9 Kaplan turbine prototype located in Porjus and its model, located in Alvkarleby, Sweden, have curved inlet pipes that lead the flow to the spiral casing. Nowadays, this curved pipe and its effect on the flow in the turbine is not taken into account when numerical simulations are performed at design stage. To study the impact of the inlet pipe curvature on the flow in the turbine, and to get a better overview of the flow of the whole system, measurements were made on the 1:3.1 model of the U9 turbine. Previously published measurements were taken at the inlet of the spiral casing and just before the guide vanes, using the laser Doppler anemometry (LDA) technique. In the draft tube, a number of velocity profiles were measured using the LDA techniques. The present work extends the experimental investigation with a horizontal section at the inlet of the draft tube. The experimental results are used to specify the inlet boundary condition for the numerical simulations in the draft tube, and to validate the computational results in both the spiral casing and the draft tube. The numerical simulations were realized using the standard k-e model and a block-structured hexahedral wall function mesh.

  7. Validation of Code ASTEC with LIVE-L1 Experimental Results

    International Nuclear Information System (INIS)

    Bachrata, Andrea

    2008-01-01

    The severe accidents with core melting are considered at the design stage of project at Generation 3+ of Nuclear Power Plants (NPP). Moreover, there is an effort to apply the severe accident management to the operated NPP. The one of main goals of severe accidents mitigation is corium localization and stabilization. The two strategies that fulfil this requirement are: the in-vessel retention (e.g. AP-600, AP- 1000) and the ex-vessel retention (e.g. EPR). To study the scenario of in-vessel retention, a large experimental program and the integrated codes have been developed. The LIVE-L1 experimental facility studied the formation of melt pools and the melt accumulation in the lower head using different cooling conditions. Nowadays, a new European computer code ASTEC is being developed jointly in France and Germany. One of the important steps in ASTEC development in the area of in-vessel retention of corium is its validation with LIVE-L1 experimental results. Details of the experiment are reported. Results of the ASTEC (module DIVA) application to the analysis of the test are presented. (author)

  8. Main Experimental Results of ISTC-1606 for Recycling and Transmutation in Molten Salt Systems

    Energy Technology Data Exchange (ETDEWEB)

    Ignatiev, Victor; Feynberg, Olga; Merzlyakov, Aleksandr; Surenkov, Aleksandr [Russian Research Center - Kurchatov Institute, Kurchatov sq. 1, Moscow, RF, 123182 (Russian Federation); Subbotin, Vladimir; Zakirov, Raul; Toropov, Andrey; Panov, Aleksandr [Russian Federal Nuclear Center - Institute of Technical Physics, Snezhinsk (Russian Federation); Afonichkin, Valery [Institute of High-Temperature Electrochemistry, Ekaterinburg (Russian Federation)

    2008-07-01

    To examine and demonstrate the feasibility of molten salt reactors (MSR) to reduce long lived waste toxicity and to produce efficiently electricity in closed fuel cycle, some national and international studies were initiated last years. In this paper main focus is placed on experimental evaluation of single stream Molten Salt Actinide Recycler and Transmuter (MOSART) system fuelled with different compositions of plutonium plus minor actinide trifluoride (AnF{sub 3}) from LWR spent nuclear fuel without U-Th support. This paper summarizes main experimental results of ISTC-1606 related to physical and chemical properties of fuel salt, container materials for fuel circuit, and fuel salt clean up of MOSART system. As result of ISTC-1606 studies claim is made, that the {sup 7}Li,Na,Be/F and {sup 7}Li,Be/F solvents selected for primary system appear to resolve main reactor physics, thermal hydraulics, materials compatibility, fuel salt clean up and safety problems as applied to the MOSART concept development. The created experimental facilities and the database on properties of fuel salt mixtures and container materials are used for a choice and improvement fuel salts and coolants for new applications of this high temperature technology for sustainable nuclear power development. (authors)

  9. Preliminary Experimental Results for Indirect Vector-Control of Induction Motor Drives with Forced Dynamics

    Directory of Open Access Journals (Sweden)

    Jan Vittek

    2003-01-01

    Full Text Available The contribution presents an extension of indirect vector control of electric drives employing induction motors to 'Forced Dynamic Control'. This method of control offers an accurate realisation of dynamic response profiles, which can be selected by the user. The developed system can be integrated into a drive with a shaft position encoder or a shaft sensoriess drive, in which only the stator currents are measured. The applied stator voltages are determined by a computed inverter switching algorithm. Simulation results and preliminary experimental results for indirect vector control of an idle running induction motor indicate good agreement with the theoretical predictions.

  10. First experimental results and simulation for gas optimisation of the MART-LIME detector

    International Nuclear Information System (INIS)

    Bazzano, A.; Brunetti, M.T.; Cocchi, M.; Hall, C.J.; Lewis, R.A.; Natalucci, L.; Ortuno-Prados, F.; Ubertini, P.

    1996-01-01

    A large area high pressure multi-wire proportional counter (MWPC), with both spatial and spectroscopic capabilities, is being jointly developed by the Istituto di Astrofisica Spaziale (IAS), CNR, Frascati, Italy and the Daresbury Laboratory (DL), Warrington, UK as part of the MART-LIME telescope. Recent test results (October-December 1995) carried out at the DL facilities are presented. A brief study, by means of a simulation program, on the possible gas mixtures to be employed in the MART-LIME detector is also reported. The results of the simulation are compared with the experimental data obtained from the tests. (orig.)

  11. Dimethyl Ether: New Advances in Wear Testing: Theoretical and Experimental Results

    DEFF Research Database (Denmark)

    Sivebæk, Ion Marius; Sorenson, Spencer C; Jakobsen, J.

    2003-01-01

    The issues addressed in this paper are investigation of the wear mechanisms present in the standard lubricity test for diesel oil: The High frequency reciprocating Rig (HFRR). The HFRR is a laboratory wear test using a ball on disk configuration. The result of a test is the wear scar diameter (WSD...... surfaces with long-range elasticity. This last property has enabled the model to correlate well with experimental results. The outcome of the alkane calculations indicates that the longer ones lubricate better than the shorts ones but not necessarily because of viscosity differences. The reason is more...

  12. Experimental results on polarized structure functions in deep inelastic lepton-nucleon scattering

    International Nuclear Information System (INIS)

    Stuart, L.

    1994-08-01

    A summary is given of experimental results on spin structure functions of the proton g 1 p (x,Q 2 ), deuteron g 1 d (x,Q 2 ), and neutron g 1 n (x,Q 2 ) as measured in deep inelastic scattering of polarized leptons from a polarized target. All results are consistent with the Bjorken sum rule predictions at the Q 2 of each experiment. The data do not support the Ellis-Jaffe sum rule prediction for the proton which implies that the hencity carried by the strange quark may be nonzero and that the net quark helicity is smaller than expected from simple quark models

  13. Use of impedance threshold device in conjunction with our novel adhesive glove device for ACD-CPR does not result in additional chest decompression.

    Science.gov (United States)

    Shih, Andre; Udassi, Sharda; Porvasnik, Stacy L; Lamb, Melissa A; Badugu, Srinivasarao; Venkata, Giridhar Kaliki; Lopez-Colon, Dalia; Haque, Ikram U; Zaritsky, Arno L; Udassi, Jai P

    2013-10-01

    To evaluate the hemodynamic effects of using an adhesive glove device (AGD) to perform active compression-decompression CPR (AGD-CPR) in conjunction with an impedance threshold device (ITD) in a pediatric cardiac arrest model. Controlled, randomized animal study. In this study, 18 piglets were anesthetized, ventilated, and continuously monitored. After 3min of untreated ventricular fibrillation, animals were randomized (6/group) to receive either standard CPR (S-CPR), active compression-decompression CPR via adhesive glove device (AGD-CPR) or AGD-CPR along with an ITD (AGD-CPR+ITD) for 2min at 100-120compressions/min. AGD is delivered using a fingerless leather glove with a Velcro patch on the palmer aspect and the counter Velcro patch adhered to the pig's chest. Data (mean±SD) were analyzed using one-way ANOVA with pair wise multiple comparisons to assess differences between groups. p-Value≤0.05 was considered significant. Both AGD-CPR and AGD-CPR+ITD groups produced lower intrathoracic pressure (IttP, mmHg) during decompression phase (-13.4±6.7, p=0.01 and -11.9±6.5, p=0.01, respectively) in comparison to S-CPR (-0.3±4.2). Carotid blood flow (CBF, % of baseline mL/min) was higher in AGD-CPR and AGD-CPR+ITD (respectively 64.3±47.3%, p=0.03 and 67.5±33.1%, p=0.04) as compared with S-CPR (29.1±12.5%). Coronary perfusion pressure (CPP, mmHg) was higher in AGD-CPR and AGD-CPR+ITD (respectively 19.7±4.6, p=0.04 and 25.6±12.1, p=0.02) when compared to S-CPR (9.6±9.1). There was no statistically significant difference between AGD-CPR and AGD-CPR+ITD groups with reference to intra-thoracic pressure, carotid blood flow and coronary perfusion pressure. Active compression decompression delivered by this simple and inexpensive adhesive glove device resulted in improved cerebral blood flow and coronary perfusion pressure. There was no statistically significant added effect of ITD use along with AGD-CPR on the decompression of the chest. Copyright © 2013 Elsevier

  14. Some experimental results of the investigation of hadron-nucleus and nucleus-nucleus interactions

    International Nuclear Information System (INIS)

    Azimov, S.A.; Gulamov, K.G.; Chernov, G.M.

    1978-01-01

    Recent experimental data on the hadron-nucleus and nucleus-nucleus inelastic interactions are analyzed. A particular attention is paid to the description of the leading hadron spectra and of the spectra of nucleon recoils in hadron-nucleus interactions. Some of the results of the experimental studies of correlations between secondary particles are discussed. This discussion demonstrates that an analysis of the multiparticle phenomena is very promising regarding the discrimination between the different models for the hadron-nucleus and nucleus-nucleus interactions. It is pointed out that the actual mechanism of the hadron-nucleus and nucleus-nucleus interactions is a rather complex one and can be described comprehensively by none of the existing models

  15. Sub-millimeter planar imaging with positron emitters: EGS4 code simulation and experimental results

    International Nuclear Information System (INIS)

    Bollini, D.; Del Guerra, A.; Di Domenico, G.

    1996-01-01

    Experimental data for Planar Imaging with positron emitters (pulse height, efficiency and spatial resolution) obtained with two matrices of 25 crystals (2 x 2 x 30 mm 3 each) of YAP:Ce coupled with a Position Sensitive PhotoMultiplier (Hamamatsu R2486-06) have been reproduced with high accuracy using the EGS4 code. Extensive simulation provides a detailed description of the performance of this type of detector as a function of the matrix granularity, the geometry of the detector and detection threshold. We present the Monte Carlo simulation and the preliminary experimental results of a prototype planar imaging system made of two matrices, each one consisting of 400 (2 x 2 x 30 mm 3 ) crystals of YAP-Ce

  16. Linear elastic obstacles: analysis of experimental results in the case of stress dependent pre-exponentials

    International Nuclear Information System (INIS)

    Surek, T.; Kuon, L.G.; Luton, M.J.; Jones, J.J.

    1975-01-01

    For the case of linear elastic obstacles, the analysis of experimental plastic flow data is shown to have a particularly simple form when the pre-exponential factor is a single-valued function of the modulus-reduced stress. The analysis permits the separation of the stress and temperature dependence of the strain rate into those of the pre-exponential factor and the activation free energy. As a consequence, the true values of the activation enthalpy, volume and entropy also are obtained. The approach is applied to four sets of experimental data, including Zr, and the results for the pre-exponential term are examined for self-consistency in view of the assumed functional dependence

  17. Reflectivity of 1D photonic crystals: A comparison of computational schemes with experimental results

    Science.gov (United States)

    Pérez-Huerta, J. S.; Ariza-Flores, D.; Castro-García, R.; Mochán, W. L.; Ortiz, G. P.; Agarwal, V.

    2018-04-01

    We report the reflectivity of one-dimensional finite and semi-infinite photonic crystals, computed through the coupling to Bloch modes (BM) and through a transfer matrix method (TMM), and their comparison to the experimental spectral line shapes of porous silicon (PS) multilayer structures. Both methods reproduce a forbidden photonic bandgap (PBG), but slowly-converging oscillations are observed in the TMM as the number of layers increases to infinity, while a smooth converged behavior is presented with BM. The experimental reflectivity spectra is in good agreement with the TMM results for multilayer structures with a small number of periods. However, for structures with large amount of periods, the measured spectral line shapes exhibit better agreement with the smooth behavior predicted by BM.

  18. Comparison between maximum radial expansion of ultrasound contrast agents and experimental postexcitation signal results.

    Science.gov (United States)

    King, Daniel A; O'Brien, William D

    2011-01-01

    Experimental postexcitation signal data of collapsing Definity microbubbles are compared with the Marmottant theoretical model for large amplitude oscillations of ultrasound contrast agents (UCAs). After taking into account the insonifying pulse characteristics and size distribution of the population of UCAs, a good comparison between simulated results and previously measured experimental data is obtained by determining a threshold maximum radial expansion (Rmax) to indicate the onset of postexcitation. This threshold Rmax is found to range from 3.4 to 8.0 times the initial bubble radius, R0, depending on insonification frequency. These values are well above the typical free bubble inertial cavitation threshold commonly chosen at 2R0. The close agreement between the experiment and models suggests that lipid-shelled UCAs behave as unshelled bubbles during most of a large amplitude cavitation cycle, as proposed in the Marmottant equation.

  19. Comparison of Experimental Surface and Flow Field Measurements to Computational Results of the Juncture Flow Model

    Science.gov (United States)

    Roozeboom, Nettie H.; Lee, Henry C.; Simurda, Laura J.; Zilliac, Gregory G.; Pulliam, Thomas H.

    2016-01-01

    Wing-body juncture flow fields on commercial aircraft configurations are challenging to compute accurately. The NASA Advanced Air Vehicle Program's juncture flow committee is designing an experiment to provide data to improve Computational Fluid Dynamics (CFD) modeling in the juncture flow region. Preliminary design of the model was done using CFD, yet CFD tends to over-predict the separation in the juncture flow region. Risk reduction wind tunnel tests were requisitioned by the committee to obtain a better understanding of the flow characteristics of the designed models. NASA Ames Research Center's Fluid Mechanics Lab performed one of the risk reduction tests. The results of one case, accompanied by CFD simulations, are presented in this paper. Experimental results suggest the wall mounted wind tunnel model produces a thicker boundary layer on the fuselage than the CFD predictions, resulting in a larger wing horseshoe vortex suppressing the side of body separation in the juncture flow region. Compared to experimental results, CFD predicts a thinner boundary layer on the fuselage generates a weaker wing horseshoe vortex resulting in a larger side of body separation.

  20. COMPARISON OF NUMERICAL AND EXPERIMENTAL RESULTS FOR OVERTOPPING DISCHARGE OF THE OBREC WAVE ENERGY CONVERTER

    Directory of Open Access Journals (Sweden)

    A. YAZID MALIKI

    2017-05-01

    Full Text Available OBREC is the latest innovation of overtopping wave energy converter (WEC which is coalesced with the rubble mound breakwaters. The acquisition of wave overtopping in a front reservoir and consequently releasing process through turbine is the concept of energy production in OBREC. The physical scale model studies of overtopping discharge of the OBREC have recently been done by previous researcher in wave flume at Aalborg University. This paper demonstrates the overtopping behavior of OBREC device using a VOF method with capabilities to solve RANS equation in the numerical suite Flow3D. The purpose of this research is to validate the overtopping discharge performance of the numerical model against the experiments of the OBREC. Based on the observation, the results have shown a good agreement between the validation and physical experiment.

  1. Optimized Control Strategy for a Medium-Voltage DVR-Theoretical Investigations and Experimental Results

    DEFF Research Database (Denmark)

    Meyer, Christoph; De Doncker, Rik W.; Li, Yun Wei

    2008-01-01

    Most power quality problems in distribution systems are related to voltage sags. Therefore, different solutions have been examined to compensate these sags to avoid production losses at sensitive loads. Dynamic voltage restorers (DVRs) have been proposed to provide higher power quality. Currently......, a system wide integration of DVRs is hampered because of their high cost, in particular, due to the expensive DC-link energy storage devices. The cost of these DC-link capacitors remains high because the DVR requires a minimum DC-link voltage to be able to operate and to compensate a sag. As a result, only...... a small fraction of the energy stored in the DC-link capacitor is used, which makes it impractical for DVRs to compensate relatively long voltage sags. Present control strategies are only able to minimize the distortions at the load or to allow a better utilization of the storage system by minimizing...

  2. StructUre and test results of the Tokamak-7 device cryogenic system

    International Nuclear Information System (INIS)

    Babaev, I.V.; VolobUev, A.N.; Zhul'kin, V.F.

    1982-01-01

    A cryogenic system (CS) of the Tokamak-7 (T-7) installation with the longitudinal field superconducting magnetic system (SMS) is described. The CS is designed for cool-down, cryostatic cooling and heating of the T-7 cryogenic objects and consists of a helium system (HS) and a nitrogen cryogenic system (NCS). The HS consists of:a a heliUm delivery system intended for distributing and controlling the helium flows in the SMS; cryogenic helium units; a 1.25 m 3 volume for storing liquid helium; a compressor compartment using piston compressors at the 3 MPa operating pressure and 140 g/s total capacity; gaseous helium storages (3600 m 3 under normal conditions); helium cleaning and drying systems; a gas holder of 20 m 3 operating volume; cryogenic pipelines and pipe fittings. The NCS operates on delivered nitrogen and includes a 120 m 3 liquid nitrogen storage, evaporators and electric heaters producing up to 230 g/s of gaseous nitrogen at 300 K, a separator, cryogenic pipelines and fittings. It is found that the CS has the necessary cold production reserve, ensures reliable operation of the Tokamak-7 device and permits to carry out practically continuous plasma experiments

  3. Photovoltaic Grid-Connected Modeling and Characterization Based on Experimental Results

    Science.gov (United States)

    Humada, Ali M.; Hojabri, Mojgan; Sulaiman, Mohd Herwan Bin; Hamada, Hussein M.; Ahmed, Mushtaq N.

    2016-01-01

    A grid-connected photovoltaic (PV) system operates under fluctuated weather condition has been modeled and characterized based on specific test bed. A mathematical model of a small-scale PV system has been developed mainly for residential usage, and the potential results have been simulated. The proposed PV model based on three PV parameters, which are the photocurrent, IL, the reverse diode saturation current, Io, the ideality factor of diode, n. Accuracy of the proposed model and its parameters evaluated based on different benchmarks. The results showed that the proposed model fitting the experimental results with high accuracy compare to the other models, as well as the I-V characteristic curve. The results of this study can be considered valuable in terms of the installation of a grid-connected PV system in fluctuated climatic conditions. PMID:27035575

  4. Photovoltaic Grid-Connected Modeling and Characterization Based on Experimental Results.

    Science.gov (United States)

    Humada, Ali M; Hojabri, Mojgan; Sulaiman, Mohd Herwan Bin; Hamada, Hussein M; Ahmed, Mushtaq N

    2016-01-01

    A grid-connected photovoltaic (PV) system operates under fluctuated weather condition has been modeled and characterized based on specific test bed. A mathematical model of a small-scale PV system has been developed mainly for residential usage, and the potential results have been simulated. The proposed PV model based on three PV parameters, which are the photocurrent, IL, the reverse diode saturation current, Io, the ideality factor of diode, n. Accuracy of the proposed model and its parameters evaluated based on different benchmarks. The results showed that the proposed model fitting the experimental results with high accuracy compare to the other models, as well as the I-V characteristic curve. The results of this study can be considered valuable in terms of the installation of a grid-connected PV system in fluctuated climatic conditions.

  5. Comparative study of methods on outlying data detection in experimental results

    International Nuclear Information System (INIS)

    Oliveira, P.M.S.; Munita, C.S.; Hazenfratz, R.

    2009-01-01

    The interpretation of experimental results through multivariate statistical methods might reveal the outliers existence, which is rarely taken into account by the analysts. However, their presence can influence the results interpretation, generating false conclusions. This paper shows the importance of the outliers determination for one data base of 89 samples of ceramic fragments, analyzed by neutron activation analysis. The results were submitted to five procedures to detect outliers: Mahalanobis distance, cluster analysis, principal component analysis, factor analysis, and standardized residual. The results showed that although cluster analysis is one of the procedures most used to identify outliers, it can fail by not showing the samples that are easily identified as outliers by other methods. In general, the statistical procedures for the identification of the outliers are little known by the analysts. (author)

  6. Experimental results on 2-30 keV bremsstrahlung from thick and thin targets

    Energy Technology Data Exchange (ETDEWEB)

    Shanker, R. [Atomic Physics Laboratory, Physics Department, Banaras Hindu University, Varanasi 221005 (India)]. E-mail: rshanker@bhu.ac.in

    2006-10-15

    The recent experimental investigations on electron bremsstrahlung produced from impact of 2-30 keV electrons with thick solid and thin gaseous targets are reviewed. The theoretical models describing the energy and angular distributions of bremsstrahlung photons are discussed with their brief outlines and formulations to explain the experimental data. The results on thick target bremsstrahlung (TTB) spectra produced by keV electrons have suggested that there is a need to develop a comprehensive theory for accounting the solid state effects. It is further noted that the prediction of the modified KKD formula gives a reasonable agreement with the TTB data, whereas a semi-empirical formula gives a better fit to the data for thick targets. The available experimental data for dependence of double differential cross-sections of emitted photons on impact energy and their emission angles for gaseous atoms and molecules exhibit a good agreement with the theoretical calculations of Kissel et al., [1983. Shape functions for atomic-field bremsstrahlung from electrons of kinetic energy 1-500 keV on selected neutral atoms 1

  7. Plasma exhaust purification by thermal swing adsorption: Experimental results and modeling

    International Nuclear Information System (INIS)

    Ricapito, I.; Malara, R.C.

    1996-01-01

    For several years at the Joint Research Centre-Ispra laboratories, cyclic adsorption processes have been developed for the purification of the plasma exhaust stream of a deuterium-tritium fusion reactor. A purification process consisting of two coupled thermal swing adsorption systems seemed to be the most convenient process. In this context, a screening study was carried out to select the most suitable adsorbent materials and appropriate working temperatures. This was mainly done by experimental measurements of adsorption isotherms of the single components of the plasma exhaust stream and by a careful evaluation of the multicomponent adsorption equilibria. Experiments on adsorption dynamics were carried out in a pilot plant to demonstrate the feasibility and to evaluate the performance of the process. The experimental apparatus was designed to treat gas mixture flow rates up to 20 to 30 standard temperature and pressure l/h. A mathematical model was developed and tested against the experimental results to describe the adsorption process and, in particular, to evaluate and to optimize the process cycle time. 27 refs., 4 figs., 9 tabs

  8. Experimental results from a pilot plant for the ammonia removal from drinkable supply

    International Nuclear Information System (INIS)

    Bruno, G.; Di Sabatino, B.

    2001-01-01

    Ion exchange represents a valid alternative to chlorination for ammonia removal from drinking water, because it allows to prevent the main disadvantage of the chlorination process, i.e. the production of chlorinated organic compounds, which may be cancerous, occurring when the water to be treated contains organic substances. Ion exchange can be carried out by means of natural zeolites. Zeolites are microcrystalline aluminosilicates minerals, being common constituents of the quaternary tuffs emitted by volcanic alkaline - potassic districts of Lazio (Italy). Particularly, phyllipsite and chabasite were selected among several zeolites species because of their high specific selectivity with ammonium ion and high theoretical exchange capacity (3.5 meq/g). The concentrations of such mineral in the rocks employed were about 40-50%. A preliminary experimental step was performed in order to select the main operative parameters. Then, a pilot plant was built up at the 'Acquedotto Municipale' of Turin (Italy), made by filtration columns. A nitrifying biomass was observed to grow onto the zeolite granules, thus forming a combined chemical-biological system allowing a high removal efficiency to be attained throughout the experimental campaigns. The present paper deals with the results obtained from a two-year experimental investigation [it

  9. Investigating dynamic parameters in HWZPR ased on the experimental and calculated results

    Energy Technology Data Exchange (ETDEWEB)

    Nasrazadani, Zahra; Behfamia, Manochehar; Khosandi, Jamshid; Mirvakili, Mohammad [Reactors Research School, Nuclear Science And Technology Research Institute, Atomic Energy Organization of Iran, Esfahan (Iran, Islamic Republic of)

    2016-10-15

    The neutron decay constant, α, and effective delayed neutron fraction, β{sub eff}, are important parameters for the control of the dynamic behavior of nuclear reactors. For the heavy water zero power reactor (HWZPR), this document describes the measurements of the neutron decay constant by noise analysis methods, including variance to mean (VTM) ratio and endogenous pulse source (EPS) methods. The measured α is successively used to determine the experimental value of the effective delayed neutron fraction as well. According to the experimental results, β{sub eff} of the HWZPR reactor under study is equal to 7.84e-3. This value is finally used to validate the calculation of the effective delayed neutron fraction by the Monte Carlo methods that are discussed in the document. Using the Monte Carlo N-Particle (MCNP)-4C code, a β{sub eff} value of 7.58e-3 was obtained for the reactor under study. Thus, the relative difference between the β{sub eff} values determined experimentally and by Monte Carlo methods was estimated to be < 4%.

  10. Solubility of water in fluorocarbons: Experimental and COSMO-RS prediction results

    International Nuclear Information System (INIS)

    Freire, Mara G.; Carvalho, Pedro J.; Santos, Luis M.N.B.F.; Gomes, Ligia R.; Marrucho, Isabel M.; Coutinho, Joao A.P.

    2010-01-01

    This work aims at providing experimental and theoretical information about the water-perfluorocarbon molecular interactions. For that purpose, experimental solubility results for water in cyclic and aromatic perfluorocarbons (PFCs), over the temperature range between (288.15 and 318.15) K, and at atmospheric pressure, were obtained and are presented. From the experimental solubility dependence on temperature, the partial molar solution and solvation thermodynamic functions such as Gibbs free energy, enthalpy and entropy were determined and are discussed. The process of dissolution of water in PFCs is shown to be spontaneous for cyclic and aromatic compounds. It is demonstrated that the interactions between the non-aromatic PFCs and water are negligible while those between aromatic PFCs and water are favourable. The COSMO-RS predictive capability was explored for the description of the water solubility in PFCs and others substituted fluorocompounds. The COSMO-RS is shown to be a useful model to provide reasonable predictions of the solubility values, as well as to describe their temperature and structural modifications dependence. Moreover, the molar Gibbs free energy and molar enthalpy of solution of water are predicted remarkably well by COSMO-RS while the main deviations appear for the prediction of the molar entropy of solution.

  11. Comparison of Computational and Experimental Microphone Array Results for an 18%-Scale Aircraft Model

    Science.gov (United States)

    Lockard, David P.; Humphreys, William M.; Khorrami, Mehdi R.; Fares, Ehab; Casalino, Damiano; Ravetta, Patricio A.

    2015-01-01

    An 18%-scale, semi-span model is used as a platform for examining the efficacy of microphone array processing using synthetic data from numerical simulations. Two hybrid RANS/LES codes coupled with Ffowcs Williams-Hawkings solvers are used to calculate 97 microphone signals at the locations of an array employed in the NASA LaRC 14x22 tunnel. Conventional, DAMAS, and CLEAN-SC array processing is applied in an identical fashion to the experimental and computational results for three different configurations involving deploying and retracting the main landing gear and a part span flap. Despite the short time records of the numerical signals, the beamform maps are able to isolate the noise sources, and the appearance of the DAMAS synthetic array maps is generally better than those from the experimental data. The experimental CLEAN-SC maps are similar in quality to those from the simulations indicating that CLEAN-SC may have less sensitivity to background noise. The spectrum obtained from DAMAS processing of synthetic array data is nearly identical to the spectrum of the center microphone of the array, indicating that for this problem array processing of synthetic data does not improve spectral comparisons with experiment. However, the beamform maps do provide an additional means of comparison that can reveal differences that cannot be ascertained from spectra alone.

  12. Analysis and experimental study on the effect of a resonant tube on the performance of acoustic levitation devices

    OpenAIRE

    Hai Jiang; Jianfang Liu; Qingqing Lv; Shoudong Gu; Xiaoyang Jiao; Minjiao Li; Shasha Zhang

    2016-01-01

    The influence of a resonant tube on the performance of acoustic standing wave-based levitation device (acoustic levitation device hereinafter) is studied by analyzing the acoustic pressure and levitation force of four types of acoustic levitation devices without a resonance tube and with resonance tubes of different radii R using ANSYS and MATLAB. Introducing a resonance tube either enhances or weakens the levitation strength of acoustic levitation device, depending on the resonance tube radi...

  13. Liquid blanket MHD effects experimental results from LMEL facility at SWIP

    International Nuclear Information System (INIS)

    Xu Zengyu; Pan Chuanjie; Liu Yong; Pan Chuanhong; Reed, C.B.

    2007-01-01

    The self-cooled /helium-cooled liquid metal blanket concept is an attractive ITER and DEMO blanket candidate as it has low operating pressure, simplicity, and a convenient tritium breeding cycle. But MHD pressure drop remains a key issue, especially in ducts with flow channel inserts (FCI), where the reduction in MHD pressure drop is difficult to predict with existing tools, and there are no available experimental data to check current predictions. To understand well various kinds of MHD effects, it is important for us to analyze and understand FCI effects. In this paper, we present measurements of the MHD effects due to off normal power shutdown, two-dimensional effects due to channel velocity profiles, three-dimensional effects caused by manifolds, and surface/bulk instability effects as a result of insulator coating imperfections. These results were collected from the Liquid Metal Experimental Loop (LMEL) facility at Southwestern Institute of Physics, China and in collaboration with Argonne National Laboratory, US under an umbrella of the People's Republic of China/United States program of cooperation in magnetic fusion. Some results were observed for the first time, such as two dimensional effects and instabilities due to insulator coating imperfections. The experiments were conducted under the following conditions: a uniform magnetic field volume of 80 x 170 x 740 mm and a maximum value of magnetic field, B 0 , of 2 Tesla. The mean flow velocity v 0 was measured with an electromagnetic (EM) flow meter (error of 1.2%); a Liquid-metal Electro-magnetic Velocity Instrument (LEVI) was provided by Argonne National Laboratory. The flow was driven by two Electro-magnetic (EM) pumps (6.5+11.6 m3/h); the operating temperature was 85 centigrade degree due to self-heating by the EM pump and friction of the fluid against the loop piping. Experimental parameters were: Hartmann number, M, up to 3500, velocity v 0 up to 1.2 m/s under magnetic field, and B 0 =1.95 Tesla

  14. Wind refrigeration : design and results of an experimental facility; Refrigeracion eolica: Diseno y resultados de una instalacion experimental

    Energy Technology Data Exchange (ETDEWEB)

    Beltran, R. G.; Talero, A.

    2004-07-01

    This article describes the experimental setup used to obtain design parameters for a wind driven refrigeration equipment. The system compressor is directly coupled to the wind mill and will provide refrigeration to a community located in La Guajira in northern Colombia. The testing on the experimental installation assessed the refrigeration capacity that could be provided by an open type commercial compressor coupled to the wind mill axis. Power and torque requirements have been evaluated for different wind mill rotational speeds. An assessment of the local conditions relating to wind speed, frequency and preferred direction for the installation site has been made based on measurements by the Meteorological National Institute and independent data from other sources. (Author)

  15. Comparison of experimental data with results of some drying models for regularly shaped products

    Energy Technology Data Exchange (ETDEWEB)

    Kaya, Ahmet [Aksaray University, Department of Mechanical Engineering, Aksaray (Turkey); Aydin, Orhan [Karadeniz Technical University, Department of Mechanical Engineering, Trabzon (Turkey); Dincer, Ibrahim [University of Ontario Institute of Technology, Faculty of Engineering and Applied Science, Oshawa, ON (Canada)

    2010-05-15

    This paper presents an experimental and theoretical investigation of drying of moist slab, cylinder and spherical products to study dimensionless moisture content distributions and their comparisons. Experimental study includes the measurement of the moisture content distributions of slab and cylindrical carrot, slab and cylindrical pumpkin and spherical blueberry during drying at various temperatures (e.g., 30, 40, 50 and 60 C) at specific constant velocity (U = 1 m/s) and the relative humidity {phi}=30%. In theoretical analysis, two moisture transfer models are used to determine drying process parameters (e.g., drying coefficient and lag factor) and moisture transfer parameters (e.g., moisture diffusivity and moisture transfer coefficient), and to calculate the dimensionless moisture content distributions. The calculated results are then compared with the experimental moisture data. A considerably high agreement is obtained between the calculations and experimental measurements for the cases considered. The effective diffusivity values were evaluated between 0.741 x 10{sup -5} and 5.981 x 10{sup -5} m{sup 2}/h for slab products, 0.818 x 10{sup -5} and 6.287 x 10{sup -5} m{sup 2}/h for cylindrical products and 1.213 x 10{sup -7} and 7.589 x 10{sup -7} m{sup 2}/h spherical products using the model-I and 0.316 x 10{sup -5}-5.072 x 10{sup -5} m{sup 2}/h for slab products, 0.580 x 10{sup -5}-9.587 x 10{sup -5} m{sup 2}/h for cylindrical products and 1.408 x 10{sup -7}-13.913 x 10{sup -7} m{sup 2}/h spherical products using the model-II. (orig.)

  16. Comparison of experimental data with results of some drying models for regularly shaped products

    Science.gov (United States)

    Kaya, Ahmet; Aydın, Orhan; Dincer, Ibrahim

    2010-05-01

    This paper presents an experimental and theoretical investigation of drying of moist slab, cylinder and spherical products to study dimensionless moisture content distributions and their comparisons. Experimental study includes the measurement of the moisture content distributions of slab and cylindrical carrot, slab and cylindrical pumpkin and spherical blueberry during drying at various temperatures (e.g., 30, 40, 50 and 60°C) at specific constant velocity ( U = 1 m/s) and the relative humidity φ = 30%. In theoretical analysis, two moisture transfer models are used to determine drying process parameters (e.g., drying coefficient and lag factor) and moisture transfer parameters (e.g., moisture diffusivity and moisture transfer coefficient), and to calculate the dimensionless moisture content distributions. The calculated results are then compared with the experimental moisture data. A considerably high agreement is obtained between the calculations and experimental measurements for the cases considered. The effective diffusivity values were evaluated between 0.741 × 10-5 and 5.981 × 10-5 m2/h for slab products, 0.818 × 10-5 and 6.287 × 10-5 m2/h for cylindrical products and 1.213 × 10-7 and 7.589 × 10-7 m2/h spherical products using the Model-I and 0.316 × 10-5-5.072 × 10-5 m2/h for slab products, 0.580 × 10-5-9.587 × 10-5 m2/h for cylindrical products and 1.408 × 10-7-13.913 × 10-7 m2/h spherical products using the Model-II.

  17. Experimental analysis on a 1:2 scale model of the double light pipe, an innovative technological device for daylight transmission

    Energy Technology Data Exchange (ETDEWEB)

    Baroncini, C.; Boccia, O.; Chella, F.; Zazzini, P. [D.S.S.A.R.R. Faculty of Architecture, University ' ' G. D' Annunzio' ' Viale Pindaro 42, 65127 Pescara (Italy)

    2010-02-15

    In this paper the authors present the double light pipe, an innovative technological device, designed as an evolution of a traditional light pipe, which distributes daylight to underground areas of a building, illuminating, at the same time, the passage areas thanks to a larger collector and a second transparent pipe attached to the first one. Unlike the traditional light pipe, thanks to this double illuminating function it can be located in the middle of a room, despite its encumbrance. In this paper the technological design of the double light pipe is presented and the results of an experimental analysis on a reduced scale (1:2) model are shown. Internal illuminance data over horizontal and vertical work-planes were measured in various sky conditions with or without direct solar radiation. Being this innovative device obtained by a light pipe integrated with a second pipe, it performs like a traditional light pipe for the final room and, at the same time, illuminates the intermediate room giving it uniform and high quality light, particularly indicated for wide plant areas, such as show-rooms or museums. (author)

  18. Validation of photon-heating calculations in irradiation reactor with the experimental AMMON program and the CARMEN device

    International Nuclear Information System (INIS)

    Lemaire, Matthieu

    2015-01-01

    The temperature in the different core structures of Material-Testing Reactors (MTR) is a key physical parameter for MTRs' performance and safety. In nuclear reactors, where neutron and photon flux are sustained by fission chain reactions, neutrons and photons steadily deposit energy in the structures they cross and lead to a temperature rise in these structures. In non-fissile core structures (such as material samples, experimental devices, control rods, fuel claddings, and so on), the main part of nuclear heating is induced by photon interactions. This photon heating must therefore be well calculated as it is a key input parameter for MTR thermal studies, whose purpose is for instance to help determine the proper sizing of cooling power, electrical heaters and insulation gaps in MTR irradiation devices. The Jules Horowitz Reactor (JHR) is the next international MTR under construction in the south of France at CEA Cadarache research center (French Alternative Energies and Atomic Energy Commission). The JHR will be a major research infrastructure for the test of structural material and fuel behavior under irradiation. It will also produce from 25% to 50% of the European demand of medical radioisotopes for diagnostic purposes. High levels of nuclear heating are expected in the JHR core, with an absorbed-dose rate up to 20 watts per hafnium gram at nominal power (100 MW). Compared to a Pressurized-Water Reactor (PWR), the JHR is made of a specific array of materials (aluminum rack, beryllium reflector, hafnium control rods) and the feedback on photon-heating calculations with these features is limited. It is therefore necessary to validate photon-heating calculation tools (calculation codes and the European nuclear-data JEFF3.1.1 library) for use in the JHR, that is, it is necessary to determine the biases and uncertainties that are relevant for the photon-heating values calculated with these tools in the JHR. This topic constitutes the core of the present

  19. NATURAL GAS VARIABILITY IN CALIFORNIA: ENVIRONMENTAL IMPACTS AND DEVICE PERFORMANCE EXPERIMENTAL EVALUATION OF POLLUTANT EMISSIONS FROM RESIDENTIAL APPLIANCES

    Energy Technology Data Exchange (ETDEWEB)

    Singer, Brett C.; Apte, Michael G.; Black, Douglas R.; Hotchi, Toshifumi; Lucas, Donald; Lunden, Melissa M.; Mirer, Anna G.; Spears, Michael; Sullivan, Douglas P.

    2009-12-01

    The effect of liquefied natural gas on pollutant emissions was evaluated experimentally with used and new appliances in the laboratory and with appliances installed in residences, targeting information gaps from previous studies. Burner selection targeted available technologies that are projected to comprise the majority of installed appliances over the next decade. Experiments were conducted on 13 cooktop sets, 12 ovens, 5 broiler burners, 5 storage water heaters, 4 forced air furnaces, 1 wall furnace, and 6 tankless water heaters. Air-free concentrations and fuel-based emission factors were determined for carbon monoxide, nitrogen oxides, nitrogen dioxide, and the number of (predominantly ultrafine) particles over complete burns?including transient effects (device warm-up and intermittent firing of burners) following ignition--and during more stable end-of-burn conditions. Formaldehyde was measured over multi-burn cycles. The baseline fuel was Northern California line gas with Wobbe number (a measure of fuel energy delivery rate) of 1320-1340; test fuels had Wobbe numbers of roughly 1390 and 1420, and in some cases 1360. No ignition or operational problems were observed during test fuel use. Baseline emissions varied widely across and within burner groups and with burner operational mode. Statistically significant emissions changes were observed for some pollutants on some burners.

  20. Experimental evaluation of an automated endoscope reprocessor with in situ generation of peracetic acid for disinfection of semicritical devices.

    Science.gov (United States)

    Sattar, Syed A; Kibbee, Richard J; Tetro, Jason A; Rook, Tony A

    2006-11-01

    To evaluate the effectiveness of a high-level disinfection solution generated inside an endoscope processing system for decontaminating external and internal surfaces of experimentally contaminated heat-sensitive medical devices. The American Society for Testing and Materials Simulated-Use Test protocol (E1837-02), which incorporates a soil load in each inoculum, was used to evaluate the efficacy of the system when processing 4 common types of endoscopes contaminated separately with 5 types of nosocomial pathogens: Pseudomonas aeruginosa (ATCC 15442), spores of Clostridium difficile (ATCC 9689), a glutaraldehyde-resistant strain of Mycobacterium chelonae, a vancomycin-resistant strain of Enterococcus faecalis, and a methicillin-resistant strain of Staphylococcus aureus. Rinse solution samples from channels and from surfaces of the processed endoscopes were tested for any microbicidal residues. For all organisms tested, the baseline level of contamination of the endoscopes ranged from 5 log(10) to greater than 7 log(10) at each external surface site and internal channel. All tests showed reductions in viability of the test organisms to undetectable levels. All rinse solution samples from external and internal sites of the endoscopes proved to be free of any residual microbicidal activity. The endoscope reprocessor, with its processor-generated high-level disinfection solution, successfully reduced the numbers of selected, clinically relevant pathogens to undetectable levels both in the channels and on the outside surfaces of the 4 representative endoscopes tested in this study.

  1. Silver release from nanocomposite Ag/alginate hydrogels in the presence of chloride ions: experimental results and mathematical modeling

    Energy Technology Data Exchange (ETDEWEB)

    Kostic, Danijela, E-mail: dkostic@tmf.bg.ac.rs [Innovation Center of the Faculty of Technology and Metallurgy (Serbia); Vidovic, Srđan, E-mail: srdjanhi@gmail.com; Obradovic, Bojana, E-mail: bojana@tmf.bg.ac.rs [University of Belgrade, Faculty of Technology and Metallurgy (Serbia)

    2016-03-15

    A stepwise experimental and mathematical modeling approach was used to assess silver release from nanocomposite Ag/alginate microbeads in wet and dried forms into water and into normal saline solution chosen as a simplified model for certain biological fluids (e.g., blood plasma, wound exudates, sweat, etc). Three phenomena were connected and mathematically described: diffusion of silver nanoparticles (AgNPs) within the alginate hydrogel, AgNP oxidation/dissolution and reaction with chloride ions, and diffusion of the resultant silver-chloride species. Mathematical modeling results agreed well with the experimental data with the AgNP diffusion coefficient estimated as 1.3 × 10{sup −18} m{sup 2} s{sup −1}, while the first-order kinetic rate constant of AgNP oxidation/dissolution and diffusivity of silver-chloride species were shown to be inversely related. In specific, rapid rehydration and swelling of dry Ag/alginate microbeads induced fast AgNP oxidation/dissolution reaction with Cl{sup −} and AgCl precipitation within the microbeads with the lowest diffusivity of silver-chloride species compared to wet microbeads in normal saline. The proposed mathematical model provided an insight into the phenomena related to silver release from nanocomposite Ca-alginate hydrogels relevant for use of antimicrobial devices and established, at the same time, a basis for further in-depth studies of AgNP interactions in hydrogels in the presence of chloride ions.

  2. Monte Carlo calculations and experimental results of Bonner spheres systems with a new cylindrical Helium-3 proportional counter

    CERN Document Server

    Müller, H; Bouassoule, T; Fernández, F; Pochat, J L; Tomas, M; Van Ryckeghem, L

    2002-01-01

    The experimental results on neutron energy spectra, integral fluences and equivalent dose measurements performed by means of a Bonner sphere system placed inside the containment building of the Vandellos II Nuclear Power Plant (Tarragona, Spain) are presented. The equivalent dose results obtained with this system are compared to those measured with different neutron area detectors (Berthold, Dineutron, Harwell). A realistic geometry model of the Bonner sphere system with a new cylindrical counter type 'F' (0,5NH1/1KI--Eurisys Mesures) and with a set of eight polyethylene moderating spheres is described in detail. The response function in fluence of this new device, to mono-energetic neutrons from thermal energy to 20 MeV, is calculated by the MCNP-4B code for each moderator sphere. The system has been calibrated at IPSN Cadarache facility for ISO Am-Be calibrated source and thermal neutron field, then the response functions were confirmed by measurements at PTB (Germany) for ISO recommended energies of mono-e...

  3. Review of JT-60 experimental results from June to October, 1988

    International Nuclear Information System (INIS)

    1989-03-01

    After the achievement of AEC (Atomic Energy Commission) milestone in October, 1987, a new divertor coil has been installed to produce divertor plasmas with a single null at the buttom. A pellet injector was also installed during the same shut down period. This report presents the results from the experiment held from June to October in 1988. Major experimental issues during this phase are: 1) confinement and 2) divertor characteristics of lower X-point discharges, 3) enhancement of confinement with pellet injection, 4) ion heating with ICRF of LHRF, 5) current drive with LHRF or ICRF, and evaluation of bootstrap current. (J.P.N.)

  4. Preliminary Results on the Experimental Investigation of the Structure Functions of Bound Nucleons

    Energy Technology Data Exchange (ETDEWEB)

    Bodek, Arie [Univ. of Rochester, NY (United States); Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States)

    2016-08-01

    We present preliminary results on an experimental study of the nuclear modification of the longitudinal ($\\sigma_L$) and transverse ($\\sigma_T$) structure functions of nucleons bound in nuclear targets. The origin of these modifications (commonly referred as as the EMC effect) is not fully understood. Our measurements of R= $\\sigma_L / \\sigma_T$ for nuclei ($R_A$) and for deuterium ($R_D$) indicate that nuclear modifications of the structure functions of bound nucleons are different for the longitudinal and transverse structure functions, and that contrary to expectation from several theoretical models, $R_A< R_D$.

  5. Combustion synthesis of TiB2-based cermets: modeling and experimental results

    International Nuclear Information System (INIS)

    Martinez Pacheco, M.; Bouma, R.H.B.; Katgerman, L.

    2008-01-01

    TiB 2 -based cermets are prepared by combustion synthesis followed by a pressing stage in a granulate medium. Products obtained by combustion synthesis are characterized by a large remaining porosity (typically 50%). To produce dense cermets, a subsequent densification step is performed after the combustion process and when the reacted material is still hot. To design the process, numerical simulations are carried out and compared to experimental results. In addition, physical and electrical properties of the products related to electrical contact applications are evaluated. (orig.)

  6. An experimental result of surface roughness machining performance in deep hole drilling

    Directory of Open Access Journals (Sweden)

    Mohamad Azizah

    2016-01-01

    Full Text Available This study presents an experimental result of a deep hole drilling process for Steel material at different machining parameters which are feed rate (f, spindle speed (s, the depth of the hole (d and MQL, number of drops (m on surface roughness, Ra. The experiment was designed using two level full factorial design of experiment (DoE with centre points to collect surface roughness, Ra values. The signal to noise (S/N ratio analysis was used to discover the optimum level for each machining parameters in the experiment.

  7. The Cornell field-reversed ion ring experiment FIREX: experimental design and first results

    Energy Technology Data Exchange (ETDEWEB)

    Podulka, W J; Greenly, J B; Anderson, D E; Glidden, S C; Hammer, D A; Omelchenko, Yu A; Sudan, R N [Cornell Univ., Ithaca, NY (United States). Laboratory of Plasma Studies

    1997-12-31

    The goal of FIREX (Field-reversed Ion Ring EXperiment) is to produce a fully field-reversed ring with 1 MeV protons. Such a ring requires about (2-3) x 10{sup 17} protons, or 30-50 mC of charge. This charge is to be injected as an annular proton beam through a suitable magnetic cusp configuration to produce a compact ring. The critical design issues for the ion beam accelerator are described. First experimental results of ion diode operation indicate that the design is capable of producing the required beam parameters. (author). 4 figs., 4 refs.

  8. The Cornell field-reversed ion ring experiment FIREX: experimental design and first results

    International Nuclear Information System (INIS)

    Podulka, W.J.; Greenly, J.B.; Anderson, D.E.; Glidden, S.C.; Hammer, D.A.; Omelchenko, Yu.A.; Sudan, R.N.

    1996-01-01

    The goal of FIREX (Field-reversed Ion Ring EXperiment) is to produce a fully field-reversed ring with 1 MeV protons. Such a ring requires about (2-3) x 10 17 protons, or 30-50 mC of charge. This charge is to be injected as an annular proton beam through a suitable magnetic cusp configuration to produce a compact ring. The critical design issues for the ion beam accelerator are described. First experimental results of ion diode operation indicate that the design is capable of producing the required beam parameters. (author). 4 figs., 4 refs

  9. Numerical and experimental results of a passive free yawing downwind wind turbine

    Energy Technology Data Exchange (ETDEWEB)

    Verelst, D.R.S.

    2013-09-15

    The background of this PhD study concerns a medium sized 3 bladed wind turbine in a free yawing and downwind configuration. Largely funded by an EU Marie-Curie IAPP grant, the project was jointly setup by the renewable energy consultant 3E, DTU Wind Energy and the TU Delft. The 3 bladed free yawing downwind concept is pursued in an attempt to increase the robustness of a wind turbine by eliminating the traditionally actively controlled, and sometimes failure prone yawing mechanism. Under certain conditions, such as for remote (off shore) and off grid applications, a decreased failure rate can increase the economical competitiveness significantly compared to more traditional power supplies. This work presents aeroelastic analysis and results of a wind tunnel test campaign for the 3 bladed free yawing downwind concept. The investigated topics concern free yawing stability and how it is affected by coning angle, blade sweep, and blade flexibility using both numerical and experimental methods. The wind tunnel tests were organized in the Open Jet Facility of the TU Delft, and the thesis discusses the experiment's design, construction, operation, and gives an analysis of the results. It provides a dataset to compare aeroelastic simulations with experimental results for varying yawed inflow conditions and free yawing stability. The experimental data scope is limited to rotor speed, tower base bending moment, yaw angle, and blade root flapwise bending moments measurements. Other work covered during the PhD study is a parametric blade sweep investigation for the NREL 5MW turbine, and a detailed study on load extrapolation methods based on aeroelastic simulations. It is concluded that the 3 bladed, free yawing, and downwind wind turbine can operate in a stable manner. However, numerical studies indicate a less stable operating region when the rotor flow is about to stall. The experiments confirmed the free yawing stability, but the unstable region indicated in the

  10. Experimental-demonstrative system for energy conversion using hydrogen fuel cell - preliminary results

    International Nuclear Information System (INIS)

    Stoenescu, D.; Stefanescu, I.; Patularu, I.; Culcer, M.; Lazar, R.E.; Carcadea, E.; Mirica, D. . E-mail address of corresponding author: daniela@icsi.ro; Stoenescu, D.)

    2005-01-01

    It is well known that hydrogen is the most promising solution of future energy, both for long and medium term strategies. Hydrogen can be produced using many primary sources (natural gas, methane, biomass, etc.), it can be burned or chemically react having a high yield of energy conversion, being a non-polluted fuel. This paper presents the preliminary results obtained by ICSI Rm. Valcea in an experimental-demonstrative conversion energy system made by a sequence of hydrogen purification units and a CO removing reactors until a CO level lower than 10ppm, that finally feeds a hydrogen fuel stack. (author)

  11. Active vibration absorber for the CSI evolutionary model - Design and experimental results. [Controls Structures Interaction

    Science.gov (United States)

    Bruner, Anne M.; Belvin, W. Keith; Horta, Lucas G.; Juang, Jer-Nan

    1991-01-01

    The development of control of large flexible structures technology must include practical demonstrations to aid in the understanding and characterization of controlled structures in space. To support this effort, a testbed facility has been developed to study practical implementation of new control technologies under realistic conditions. The paper discusses the design of a second order, acceleration feedback controller which acts as an active vibration absorber. This controller provides guaranteed stability margins for collocated sensor/actuator pairs in the absence of sensor/actuator dynamics and computational time delay. Experimental results in the presence of these factors are presented and discussed. The robustness of this design under model uncertainty is demonstrated.

  12. Experimental results on advanced inertial fusion schemes obtained within the HiPER project

    International Nuclear Information System (INIS)

    Batani, Dimitri; Santos, Jorge J.; Schurtz, Guy; Hulin, Sebastien; Ribeyre, Xavier; Nicolai, Philippe; Vauzour, Benjamin; Dorchies, Fabien; Gizzi, Leonida A.; Koester, Petra; Labate, Luca; Honrubia, Javier; Antonelli, Luca; Morace, Alessio; Volpe, Luca; Nazarov, Wiger; Pasley, John; Richetta, Maria; Lancaster, Kate; Spindloe, Christopher; Tolley, Martin; Neely, David; Kozlova, Michaela; Nejdl, Jaroslav; Rus, Bedrich; Wolowski, Jerzy; Badziak, Jan

    2012-01-01

    This paper presents the results of experiments conducted within the Work Package 10 (fusion experimental programme) of the HiPER project. The aim of these experiments was to study the physics relevant for advanced ignition schemes for inertial confinement fusion, i.e. the fast ignition and the shock ignition. Such schemes allow to achieve a higher fusion gain compared to the indirect drive approach adopted in the National Ignition Facility in United States, which is important for the future inertial fusion energy reactors and for realising the inertial fusion with smaller facilities. (authors)

  13. Experimental results supporting the concept of one-sided muon tomography

    Energy Technology Data Exchange (ETDEWEB)

    Boniface, K., E-mail: bonifak@mcmaster.ca [McMaster University, Hamilton, ON (Canada); Jonkmans, G. [Canadian Nuclear Laboratories, Chalk River, ON (Canada); Buijs, A. [McMaster University, Hamilton, ON (Canada); Erlandson, A.; Livingstone, S. [Canadian Nuclear Laboratories, Chalk River, ON (Canada)

    2015-07-01

    Naturally occurring cosmic-ray muons have been shown to exhibit properties ideal for imaging the interior of structures containing material of high density and atomic number. The commonly used method for 3D imaging requires two modules of detection in order to measure muon scattering. This paper provides experimental results for a novel 3D imaging method that uses a reconstruction algorithm common to medical imaging and only one module of detection in order to measure the attenuation of the muon flux at several angles of rotation around a structure. (author)

  14. Determination of the Clean Air Delivery Rate (CADR of Photocatalytic Oxidation (PCO Purifiers for Indoor Air Pollutants Using a Closed-Loop Reactor. Part II: Experimental Results

    Directory of Open Access Journals (Sweden)

    Valérie Héquet

    2017-03-01

    Full Text Available The performances of a laboratory PhotoCatalytic Oxidation (PCO device were determined using a recirculation closed-loop pilot reactor. The closed-loop system was modeled by associating equations related to two ideal reactors: a perfectly mixed reservoir with a volume of VR = 0.42 m3 and a plug flow system corresponding to the PCO device with a volume of VP = 5.6 × 10−3 m3. The PCO device was composed of a pleated photocatalytic filter (1100 cm2 and two 18-W UVA fluorescent tubes. The Clean Air Delivery Rate (CADR of the apparatus was measured under different operating conditions. The influence of three operating parameters was investigated: (i light irradiance I from 0.10 to 2.0 mW·cm−2; (ii air velocity v from 0.2 to 1.9 m·s−1; and (iii initial toluene concentration C0 (200, 600, 1000 and 4700 ppbv. The results showed that the conditions needed to apply a first-order decay model to the experimental data (described in Part I were fulfilled. The CADR values, ranging from 0.35 to 3.95 m3·h−1, were mainly dependent on the light irradiance intensity. A square root influence of the light irradiance was observed. Although the CADR of the PCO device inserted in the closed-loop reactor did not theoretically depend on the flow rate (see Part I, the experimental results did not enable the confirmation of this prediction. The initial concentration was also a parameter influencing the CADR, as well as the toluene degradation rate. The maximum degradation rate rmax ranged from 342 to 4894 ppbv/h. Finally, this study evidenced that a recirculation closed-loop pilot could be used to develop a reliable standard test method to assess the effectiveness of PCO devices.

  15. Clinical results with the Trabectome, a novel surgical device for treatment of open-angle glaucoma.

    Science.gov (United States)

    Minckler, Don; Baerveldt, George; Ramirez, Marina Alfaro; Mosaed, Sameh; Wilson, Richard; Shaarawy, Tarek; Zack, Barend; Dustin, Laurie; Francis, Brian

    2006-01-01

    To describe treatment outcomes after Trabectome surgery in an initial series of 101 patients with open-angle glaucoma. A 19-gauge microelectrosurgical device enabled ab interno removal of a strip of trabecular meshwork and inner wall of Schlemm's canal under gonioscopic control with continual infusion and foot-pedal control of aspiration and electrosurgery. A smooth, pointed ceramic-coated insulating footplate was inserted into Schlemm's canal to act as a guide within the canal and to protect adjacent structures from mechanical or heat injury during ablation of a 30- to 90-degree arc of angle tissue. Mean preoperative intraocular pressure (IOP) in the initial 101 patients was 27.6 +/- 7.2 mm Hg. Thirty months postoperatively, mean IOP was 16.3 +/- 3.3 mm Hg (n = 11). The mean percentage drop over the whole course of follow-up was 40%. At all times postoperatively, the absolute and percent decrease in IOP from preoperative levels were statistically significant (paired t test, P < .0001). Overall success (IOP

  16. A perspective on thermal annealing of reactor pressure vessel materials from the viewpoint of experimental results

    International Nuclear Information System (INIS)

    Iskander, S.K.; Sokolov, M.A.; Nanstad, R.K.

    1996-01-01

    It is believed that in the next decade or so, several nuclear reactor pressure vessels (RPVs) may exceed the reference temperature limits set by the pressurized thermal shock screening criteria. One of the options to mitigate the effects of irradiation on RPVs is to thermally anneal them to restore the toughness properties that have been degraded by neutron irradiation. This paper summarizes recent experimental results from work performed at the Oak Ridge National Laboratory to study the annealing response, or ''recovery'' of several irradiated RPV steels. The fracture toughness is one of the important properties used in the evaluation of the integrity of RPVs. Optimally, the fracture toughness is measured directly by fracture toughness specimens, such as compact tension or precracked Charpy specimens, but is often inferred from the results of Charpy V-notch impact specimens. The experimental results are compared to the predictions of models for embrittlement recovery which have been developed by Eason et al. Some of the issues in annealing that still need to be resolved are discussed

  17. Impulsivity in Multiplayer Online Battle Arena Gamers: Preliminary Results on Experimental and Self-Report Measures.

    Science.gov (United States)

    Nuyens, Filip; Deleuze, Jory; Maurage, Pierre; Griffiths, Mark D; Kuss, Daria J; Billieux, Joël

    2016-06-01

    Background and aims Multiplayer Online Battle Arena (MOBA) games have become the most popular type of video games played worldwide, superseding the playing of Massively Multiplayer Online Role-Playing Games and First-Person Shooter games. However, empirical studies focusing on the use and abuse of MOBA games are still very limited, particularly regarding impulsivity, which is an indicator of addictive states but has not yet been explored in MOBA games. In this context, the objective of the present study is to explore the associations between impulsivity and symptoms of addictive use of MOBA games in a sample of highly involved League of Legends (LoL, currently the most popular MOBA game) gamers. Methods Thirty-six LoL gamers were recruited and completed both experimental (Single Key Impulsivity Paradigm) and self-reported impulsivity assessments (s-UPPS-P Impulsive Behavior Scale, Barratt Impulsiveness Scale), in addition to an assessment of problematic video game use (Problematic Online Gaming Questionnaire). Results Results showed links between impulsivity-related constructs and signs of excessive MOBA game involvement. Findings indicated that impaired ability to postpone rewards in an experimental laboratory task was strongly related to problematic patterns of MOBA game involvement. Although less consistent, several associations were also found between self-reported impulsivity traits and signs of excessive MOBA game involvement. Conclusions Despite these results are preliminary and based upon a small (self-selected) sample, the present study highlights potential psychological factors related to the addictive use of MOBA games.

  18. Impulsivity in Multiplayer Online Battle Arena Gamers: Preliminary Results on Experimental and Self-Report Measures

    Science.gov (United States)

    Nuyens, Filip; Deleuze, Jory; Maurage, Pierre; Griffiths, Mark D.; Kuss, Daria J.; Billieux, Joël

    2016-01-01

    Background and aims Multiplayer Online Battle Arena (MOBA) games have become the most popular type of video games played worldwide, superseding the playing of Massively Multiplayer Online Role-Playing Games and First-Person Shooter games. However, empirical studies focusing on the use and abuse of MOBA games are still very limited, particularly regarding impulsivity, which is an indicator of addictive states but has not yet been explored in MOBA games. In this context, the objective of the present study is to explore the associations between impulsivity and symptoms of addictive use of MOBA games in a sample of highly involved League of Legends (LoL, currently the most popular MOBA game) gamers. Methods Thirty-six LoL gamers were recruited and completed both experimental (Single Key Impulsivity Paradigm) and self-reported impulsivity assessments (s-UPPS-P Impulsive Behavior Scale, Barratt Impulsiveness Scale), in addition to an assessment of problematic video game use (Problematic Online Gaming Questionnaire). Results Results showed links between impulsivity-related constructs and signs of excessive MOBA game involvement. Findings indicated that impaired ability to postpone rewards in an experimental laboratory task was strongly related to problematic patterns of MOBA game involvement. Although less consistent, several associations were also found between self-reported impulsivity traits and signs of excessive MOBA game involvement. Conclusions Despite these results are preliminary and based upon a small (self-selected) sample, the present study highlights potential psychological factors related to the addictive use of MOBA games. PMID:27156376

  19. Spatial distribution of charged particles along the ion-optical axis in electron cyclotron resonance ion sources. Experimental results

    International Nuclear Information System (INIS)

    Panitzsch, Lauri

    2013-01-01

    The experimental determination of the spatial distribution of charged particles along the ion-optical axis in electron cyclotron resonance ion sources (ECRIS) defines the focus of this thesis. The spatial distributions of different ion species were obtained in the object plane of the bending magnet (∼45 cm downstream from the plasma electrode) and in the plane of the plasma electrode itself, both in high spatial resolution. The results show that each of the different ion species forms a bloated, triangular structure in the aperture of the plasma electrode. The geometry and the orientation of these structures are defined by the superposition of the radial and axial magnetic fields. The radial extent of each structure is defined by the charge of the ion. Higher charge states occupy smaller, more concentrated structures. The total current density increases towards the center of the plasma electrode. The circular and star-like structures that can be observed in the beam profiles of strongly focused, extracted ion beams are each dominated by ions of a single charge state. In addition, the spatially resolved current density distribution of charged particles in the plasma chamber that impinge on the plasma electrode was determined, differentiating between ions and electrons. The experimental results of this work show that the electrons of the plasma are strongly connected to the magnetic field lines in the source and thus spatially well confined in a triangular-like structure. The intensity of the electrons increases towards the center of the plasma electrode and the plasma chamber, as well. These electrons are surrounded by a spatially far less confined and less intense ion population. All the findings mentioned above were already predicted in parts by simulations of different groups. However, the results presented within this thesis represent the first (and by now only) direct experimental verification of those predictions and are qualitatively transferable to other

  20. Spatial distribution of charged particles along the ion-optical axis in electron cyclotron resonance ion sources. Experimental results

    Energy Technology Data Exchange (ETDEWEB)

    Panitzsch, Lauri

    2013-02-08

    The experimental determination of the spatial distribution of charged particles along the ion-optical axis in electron cyclotron resonance ion sources (ECRIS) defines the focus of this thesis. The spatial distributions of different ion species were obtained in the object plane of the bending magnet ({approx}45 cm downstream from the plasma electrode) and in the plane of the plasma electrode itself, both in high spatial resolution. The results show that each of the different ion species forms a bloated, triangular structure in the aperture of the plasma electrode. The geometry and the orientation of these structures are defined by the superposition of the radial and axial magnetic fields. The radial extent of each structure is defined by the charge of the ion. Higher charge states occupy smaller, more concentrated structures. The total current density increases towards the center of the plasma electrode. The circular and star-like structures that can be observed in the beam profiles of strongly focused, extracted ion beams are each dominated by ions of a single charge state. In addition, the spatially resolved current density distribution of charged particles in the plasma chamber that impinge on the plasma electrode was determined, differentiating between ions and electrons. The experimental results of this work show that the electrons of the plasma are strongly connected to the magnetic field lines in the source and thus spatially well confined in a triangular-like structure. The intensity of the electrons increases towards the center of the plasma electrode and the plasma chamber, as well. These electrons are surrounded by a spatially far less confined and less intense ion population. All the findings mentioned above were already predicted in parts by simulations of different groups. However, the results presented within this thesis represent the first (and by now only) direct experimental verification of those predictions and are qualitatively transferable to