WorldWideScience

Sample records for developing glassy magnets

  1. Some Recent Developments in Structure and Glassy Behavior of Proteins

    Science.gov (United States)

    Hu, Chin-Kun

    2012-02-01

    We have used ARVO developed by us to find that the ratio of volume and surface area of proteins in Protein Data Bank distributed in a very narrow region [1]. Such result is useful for the determination of protein 3D structures. It has been widely known that a spin glass model can be used to understand the slow relaxation behavior of a glass at low temperatures [2]. We have used molecular dynamics and simple models of polymer chains to study relaxation and aggregation of proteins under various conditions and found that polymer chains with neighboring monomers connected by rigid bonds can relax very slowly and show glassy behavior [3]. We have also found that native collagen fibrils show glassy behavior at room temperatures [4]. The results of [3] and [4] about the glassy behavior of polymers or proteins are useful for understanding the mechanism for a biological system to maintain in a non-equilibrium state, including the ancient seed [5], which can maintain in a non-equilibrium state for a very long time. (1) M.-C. Wu, M. S. Li, W.-J. Ma, M. Kouza, and C.-K. Hu, EPL, in press (2011); (2) C. Dasgupta, S.-K. Ma, and C.-K. Hu. Phys. Rev. B 20, 3837-3849 (1979); (3) W.-J. Ma and C.-K. Hu, J. Phys. Soc. Japan 79, 024005, 024006, 054001, and 104002 (2010), C.-K. Hu and W.-J. Ma, Prog. Theor. Phys. Supp. 184, 369 (2010); S. G. Gevorkian, A. E. Allahverdyan, D. S. Gevorgyan and C.-K. Hu, EPL 95, 23001 (2011); S. Sallon, et al. Science 320, 1464 (2008).

  2. Terbium induced glassy magnetism in La,Ca-based cobaltites

    Czech Academy of Sciences Publication Activity Database

    Maryško, Miroslav; Hejtmánek, Jiří; Jirák, Zdeněk; Kaman, Ondřej; Knížek, Karel

    2014-01-01

    Roč. 115, č. 17 (2014), "17E103 -1"-"17E103 -3" ISSN 0021-8979 R&D Projects: GA ČR(CZ) GAP204/11/0713 Institutional support: RVO:68378271 Keywords : terbium * cobalt * magnetic susceptibilities Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 2.183, year: 2014

  3. Development of glassy carbon electrode (Dead Sea scroll) for low energy cardiac pacing.

    Science.gov (United States)

    Katsumoto, K; Niibori, T; Takamatsu, T; Kaibara, M

    1986-11-01

    We have developed a new type of glassy carbon electrode whose smooth surface with scattered craters reduces its polarization voltage. It has both excellent antithrombogenicity and slight tissue reaction. The energy threshold curve was the lowest when compared to the Siemens (411S, 412S) and the Solin (S-100) electrodes.

  4. Spinodals with Disorder: From Avalanches in Random Magnets to Glassy Dynamics

    Science.gov (United States)

    Nandi, Saroj Kumar; Biroli, Giulio; Tarjus, Gilles

    2016-04-01

    We revisit the phenomenon of spinodals in the presence of quenched disorder and develop a complete theory for it. We focus on the spinodal of an Ising model in a quenched random field (RFIM), which has applications in many areas from materials to social science. By working at zero temperature in the quasistatically driven RFIM, thermal fluctuations are eliminated and one can give a rigorous content to the notion of spinodal. We show that the latter is due to the depinning and the subsequent expansion of rare droplets. We work out the associated critical behavior, which, in any finite dimension, is very different from the mean-field one: the characteristic length diverges exponentially and the thermodynamic quantities display very mild nonanalyticities much like in a Griffith phenomenon. From the recently established connection between the spinodal of the RFIM and glassy dynamics, our results also allow us to conclusively assess the physical content and the status of the dynamical transition predicted by the mean-field theory of glass-forming liquids.

  5. Co-based soft magnetic bulk glassy alloys optimized for glass ...

    Indian Academy of Sciences (India)

    testing machine at a strain rate of 5 × 10. −4 s. −1 at room tem- perature using the glassy rods with a dimension of 2 mm in diameter and 4 mm in length. Is was measured with a vibrat- ing sample magnetometer (VSM) under an applied field of. 400 kA m. −1 . Hc was measured with a B–H loop tracer under a field of 800 A m.

  6. Disorder-induced critical phenomena in magnetically glassy Cu-Al-Mn alloys

    Czech Academy of Sciences Publication Activity Database

    Marcos, J.; Vives, E.; Manosa, L.; Acet, M.; Duman, E.; Morin, M.; Novák, Václav; Planes, A.

    2003-01-01

    Roč. 67, č. 22 (2003), 224406/1-224406/5 ISSN 0163-1829 Institutional research plan: CEZ:AV0Z1010914 Keywords : Cu-Mn-Al alloys * magnetic hysteresis loops Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 2.962, year: 2003

  7. A new kinetic–mechanistic approach to elucidate electrooxidation of doxorubicin hydrochloride in unprocessed human fluids using magnetic graphene based nanocomposite modified glassy carbon electrode

    Energy Technology Data Exchange (ETDEWEB)

    Soleymani, Jafar [Hematology–Oncology Research Center, Tabriz University of Medical Sciences, Tabriz 51664 (Iran, Islamic Republic of); Hasanzadeh, Mohammad, E-mail: Mhmmd_hasanzadeh@yahoo.com [Drug Applied Research Center, Tabriz University of Medical Sciences, Tabriz (Iran, Islamic Republic of); Shadjou, Nasrin [Department of Nanochemistry, Nano Technology Center, and Faculty of Chemistry, Urmia University, Urmia (Iran, Islamic Republic of); Khoubnasab Jafari, Maryam [Tuberculosis and Lung Disease Research Center, Tabriz University of Medical Sciences, Tabriz (Iran, Islamic Republic of); Gharamaleki, Jalil Vaez [Hematology–Oncology Research Center, Tabriz University of Medical Sciences, Tabriz 51664 (Iran, Islamic Republic of); Yadollahi, Mehdi [Department of Organic Chemistry, Faculty of Chemistry, Tabriz University, Tabriz (Iran, Islamic Republic of); Jouyban, Abolghasem [Pharmaceutical Analysis Research Center and Faculty of Pharmacy, Tabriz University of Medical Sciences, Tabriz (Iran, Islamic Republic of)

    2016-04-01

    A novel magnetic nanocomposite was synthesized in one step using polymerization of magnetic graph oxide grafted with chlorosulfonic acid (Fe{sub 3}O{sub 4}–GO–SO{sub 3}H) in the presence of polystyrene. The prepared magnetic nanocomposite was characterized using transmission electron microscopy (TEM), dynamic differential scanning calorimetry (DSC), thermogravimetric analysis (TGA), (Thermo-gravimetric/differential thermal analysis (DTA)), Fourier transform infrared (FTIR), and UV–Vis techniques. Magnetic nanocomposite was casted on the surface of the glassy carbon electrode (PS/Fe{sub 3}O{sub 4}–GO–SO{sub 3}H/GCE) and used for the detection and determination of doxorubicin hydrochloride (DOX) in human biological fluids. The cyclic voltammograms (CVs) of the modified electrode in aqueous solution displayed a pair of well-defined, stable and irreversible reductive/oxidation redox systems. CV study indicated that the oxidation process is irreversible and adsorption controlled. In addition, CV results indicated that DOX is oxidized via two electrons and three protons which is an unusual approach for the oxidation of DOX. A sensitive and time-saving procedure was developed for the analysis of DOX in plasma, cerebrospinal fluid, and urine with detection limit of 4.9 nM, 14 nM and 4.3 nM, respectively. - Highlights: • A novel magneto-polymeric nanocomposite (PS/Fe{sub 3}O{sub 4}–GO–SO{sub 3}H) was synthesized. • Application of PS/Fe{sub 3}O{sub 4}–GO–SO{sub 3}H toward detection of DOX was investigated by electrochemistry. • A new kinetic–mechanistic approach to elucidate electrooxidation of DOX was obtained. • DOX was detected in plasma, cerebrospinal fluid, and urine.

  8. Solvated electron structure in glassy matrices

    International Nuclear Information System (INIS)

    Kevan, L.

    1981-01-01

    Current knowledge of the detailed geometrical structure of solvated electrons in aqueous and organic media is summarized. The geometry of solvated electrons in glassy methanol, ethanol, and 2-methyltetrahydrofuran is discussed. Advanced electron magnetic resonance methods and development of new methods of analysis of electron spin echo modulation patterns, second moment line shapes, and forbidden photon spin-flip transitions for paramagnetic species in these disordered systems are discussed. 66 references are cited

  9. Glassy Dynamics

    DEFF Research Database (Denmark)

    Jensen, Henrik J.; Sibani, Paolo

    2007-01-01

    The term glassy dynamics is often used to refer to the extremely slow relaxation observed in several types of many component systems. The time span needed to reach a steady, time independent, state will typically be far beyond experimentally accessible time scales. When melted alloys are cooled...... down they typically do not enter a crystalline ordered state. Instead the atoms retain the amorphous arrangement characteristic of the liquid high temperature phase while the mobility of the molecules decreases very many orders of magnitude. This colossal change in the characteristic dynamical time...

  10. Magnetic order and glassiness in distorted triangular lattice materials, Cu2 (1 - x) Zn 2x(OH)3 NO 3/(C 7 H 15COO)

    Science.gov (United States)

    Wu, Jian; Werner, Fletcher; Wildeboer, Julia S.; Seidel, Alexander; Nussinov, Zohar; Solin, S. A.

    2011-03-01

    We discuss the magnetic properties of a class of spin S = 1 / 2 antiferromagnetic quasi-triangular lattice materials, both in the clean limit and in the presence of non-magnetic Zn impurities. These systems are long organic chain intercalated derivatives of copper hydroxy nitrate, with a very large c-axis separation of 24Å. In these compounds, we find that a spin glass phase is universally preceded by two different power law regimes in the temperature dependence of the DC magnetic susceptibility, separated by a sharp crossover. This is seen both in the presence as well as in the absence of non-magnetic Zn impurities, where the power law exponents are surprisingly unperturbed by the compositional disorder. We argue that these findings may be consistent with a picture based on a self-generated spin glass in the clean undoped compound, where frustration is the driving mechanism of the glassiness rather than disorder. While AC measurements and time dependent magnetization follow traditional spin glass paradigms, the power law structure found in the DC susceptibility is argued to deviate in various ways from scenarios expected based on Griffiths type physics, and may call for new explanations.

  11. Networks under pressure: the development of in situ high-pressure neutron diffraction for glassy and liquid materials

    International Nuclear Information System (INIS)

    Salmon, Philip S; Zeidler, Anita

    2015-01-01

    The pressure-driven collapse in the structure of network-forming materials will be considered in the gigapascal (GPa) regime, where the development of in situ high-pressure neutron diffraction has enabled this technique to obtain new structural information. The improvements to the neutron diffraction methodology are discussed, and the complementary nature of the results is illustrated by considering the pressure-driven structural transformations for several key network-forming materials that have also been investigated by using other experimental techniques such as x-ray diffraction, inelastic x-ray scattering, x-ray absorption spectroscopy and Raman spectroscopy. A starting point is provided by the pressure-driven network collapse of the prototypical network-forming oxide glasses B 2 O 3 , SiO 2 and GeO 2 . Here, the combined results help to show that the coordination number of network-forming structural motifs in a wide range of glassy and liquid oxide materials can be rationalised in terms of the oxygen-packing fraction over an extensive pressure and temperature range. The pressure-driven network collapse of the prototypical chalcogenide glass GeSe 2 is also considered where, as for the case of glassy GeO 2 , site-specific structural information is now available from the method of in situ high-pressure neutron diffraction with isotope substitution. The application of in situ high-pressure neutron diffraction to other structurally disordered network-forming materials is also summarised. In all of this work a key theme concerns the rich diversity in the mechanisms of network collapse, which drive the changes in physico-chemical properties of these materials. A more complete picture of the mechanisms is provided by molecular dynamics simulations using theoretical schemes that give a good account of the experimental results. (topical review)

  12. Networks under pressure: the development of in situ high-pressure neutron diffraction for glassy and liquid materials.

    Science.gov (United States)

    Salmon, Philip S; Zeidler, Anita

    2015-04-10

    The pressure-driven collapse in the structure of network-forming materials will be considered in the gigapascal (GPa) regime, where the development of in situ high-pressure neutron diffraction has enabled this technique to obtain new structural information. The improvements to the neutron diffraction methodology are discussed, and the complementary nature of the results is illustrated by considering the pressure-driven structural transformations for several key network-forming materials that have also been investigated by using other experimental techniques such as x-ray diffraction, inelastic x-ray scattering, x-ray absorption spectroscopy and Raman spectroscopy. A starting point is provided by the pressure-driven network collapse of the prototypical network-forming oxide glasses B2O3, SiO2 and GeO2. Here, the combined results help to show that the coordination number of network-forming structural motifs in a wide range of glassy and liquid oxide materials can be rationalised in terms of the oxygen-packing fraction over an extensive pressure and temperature range. The pressure-driven network collapse of the prototypical chalcogenide glass GeSe2 is also considered where, as for the case of glassy GeO2, site-specific structural information is now available from the method of in situ high-pressure neutron diffraction with isotope substitution. The application of in situ high-pressure neutron diffraction to other structurally disordered network-forming materials is also summarised. In all of this work a key theme concerns the rich diversity in the mechanisms of network collapse, which drive the changes in physico-chemical properties of these materials. A more complete picture of the mechanisms is provided by molecular dynamics simulations using theoretical schemes that give a good account of the experimental results.

  13. Development of Magnetic Refrigerator

    Science.gov (United States)

    Ogiwara, Hiroyasu; Nakagome, Hideki; Kuriyama, Tohru

    A series of R & D of magnetic refrigerators has been done in order to realize an advanced type cryocooler for superconducting magnets of maglev trains and MRI medical system. As a result of efforts on both the magnetic refrigerator and superconducting magnets, a parasitic type magnetic refrigeration system was proposed.

  14. Glassy magnetic ground state and Kondo-like behaviour in Mn10FeGe8 alloy

    Science.gov (United States)

    Pramanick, S.; Dutta, P.; Majumdar, S.; Chatterjee, S.

    2017-12-01

    We report a detailed investigation of the ground-state magnetic properties of newly synthesized Mn10 FeGe8 alloy. The sample can be thought of being derived by substituting one Mn atom by Fe of the parent compound Mn11 Ge8 . Fe-substitution leads to a drastic change in the magnetic ground state as well as to the magneto-transport properties of the parent alloy. On cooling below 250 K, Mn10 FeGe8 undergoes a transition from paramagnetic phase to a state having significant ferromagnetic correlations. The ground state is found to be canonical spin glass (CSG) type in nature as evident from the dc magnetization and ac susceptibility measurements. Interestingly, the resistivity data shows an upturn at low temperature below about 30 K, mimicking Kondo-like behaviour. Mn10 FeGe8 turns out to be a rare example among 3d transition metal alloys, where a Kondo-like state coexists within a CSG phase.

  15. Glassy carbon based supercapacitor stacks

    Energy Technology Data Exchange (ETDEWEB)

    Baertsch, M.; Braun, A.; Koetz, R.; Haas, O. [Paul Scherrer Inst. (PSI), Villigen (Switzerland)

    1997-06-01

    Considerable effort is being made to develop electrochemical double layer capacitors (EDLC) that store relatively large quantities of electrical energy and possess at the same time a high power density. Our previous work has shown that glassy carbon is suitable as a material for capacitor electrodes concerning low resistance and high capacity requirements. We present the development of bipolar electrochemical glassy carbon capacitor stacks of up to 3 V. Bipolar stacks are an efficient way to meet the high voltage and high power density requirements for traction applications. Impedance and cyclic voltammogram measurements are reported here and show the frequency response of a 1, 2, and 3 V stack. (author) 3 figs., 1 ref..

  16. Glassy carbon coated graphite for nuclear applications

    International Nuclear Information System (INIS)

    Delpeux S; Cacciaguerra T; Duclaux L

    2005-01-01

    Taking into account the problems caused by the treatment of nuclear wastes, the molten salts breeder reactors are expected to a great development. They use a molten fluorinated salt (mixture of LiF, BeF 2 , ThF 4 , and UF 4 ) as fuel and coolant. The reactor core, made of graphite, is used as a neutrons moderator. Despite of its compatibility with nuclear environment, it appears crucial to improve the stability and inertness of graphite against the diffusion of chemicals species leading to its corrosion. One way is to cover the graphite surface by a protective impermeable deposit made of glassy carbon obtained by the pyrolysis of phenolic resin or polyvinyl chloride precursors. The main difficulty in the synthesis of glassy carbon is to create exclusively, in the primary pyrolysis product, a micro-porosity of about twenty Angstroms which closes later at higher temperature. Therefore, the evacuation of the volatile products occurring mainly between 330 and 600 C, must progress slowly to avoid the material to crack. In this study, the optimal parameters for the synthesis of glassy carbon as well as glassy carbon deposits on nuclear-type graphite pieces are discussed. Both thermal treatment of phenolic and PVC resins have been performed. The structure and micro-texture of glassy carbon have been investigated by X-ray diffraction, scanning and transmission electron microscopies and helium pycno-metry. Glassy carbon samples (obtained at 1200 C) show densities ranging from 1.3 to 1.55 g/cm 3 and closed pores with nano-metric size (∼ 5 to 10 nm) appear clearly on the TEM micrographs. Then, a thermal treatment to 2700 C leads to the shrinkage of the entangled graphene ribbons, in good agreement with the proposed texture model for glassy carbon. Glassy carbon deposits on nuclear graphite have been developed by an impregnation method. The uniformity of the deposit depends clearly on the surface texture and the chemistry of the graphite substrate. The deposit regions where

  17. Glassy metallic plastics

    Science.gov (United States)

    Li, Jianfu; Wang, Junqiang; Liu, Xiaofeng; Zhao, Kun; Zhang, Bo; Bai, Haiyang; Pan, Mingxiang; Wang, Weihua

    2010-03-01

    This paper reports a class of bulk metallic glass including Ce-, LaCe-, CaLi-, Yb-, and Sr-based metallic glasses, which are regarded as glassy metallic plastics because they combine some unique properties of both plastics and metallic alloys. These glassy metallic plastics have very low glass transition temperature ( T g ˜25°C to 150°C) and low Young’s modulus (˜20 GPa to 35 GPa). Similar to glassy plastics, these metallic plastics show excellent plastic-like deformability on macro-, micro- and even nano-scale in their supercooled liquid range and can be processed, such as elongated, compressed, bent, and imprinted at low temperatures, in hot water for instance. Under ambient conditions, they display such metallic properties as high thermal and electric conductivities and excellent mechanical properties and other unique properties. The metallic plastics have potential applications and are also a model system for studying issues in glass physics.

  18. Glassy slags for minimum additive waste stabilization

    International Nuclear Information System (INIS)

    Feng, X.; Wronkiewicz, D.J.; Bates, J.K.; Brown, N.R.; Buck, E.C.; Dietz, N.L.; Gong, M.; Emery, J.W.

    1994-05-01

    Glassy slag waste forms are being developed to complement glass waste forms in implementing Minimum Additive Waste Stabilization (MAWS) for supporting DOE's environmental restoration efforts. The glassy slag waste form is composed of various crystalline and metal oxide phases embedded in a silicate glass phase. The MAWS approach was adopted by blending multiple waste streams to achieve up to 100% waste loadings. The crystalline phases, such as spinels, are very durable and contain hazardous and radioactive elements in their lattice structures. These crystalline phases may account for up to 80% of the total volume of slags having over 80% metal loading. The structural bond strength model was used to quantify the correlation between glassy slag composition and chemical durability so that optimized slag compositions were obtained with limited crucible melting and testing. Slag compositions developed through crucible melts were also successfully generated in a pilot-scale Retech plasma centrifugal furnace at Ukiah, California. Utilization of glassy slag waste forms allows the MAWS approach to be applied to a much wider range of waste streams than glass waste forms. The initial work at ANL has indicated that glassy slags are good final waste forms because of (1) their high chemical durability; (2) their ability to incorporate large amounts of metal oxides; (3) their ability to incorporate waste streams having low contents of flux components; (4) their less stringent requirements on processing parameters, compared to glass waste forms; and (5) their low requirements for purchased additives, which means greater waste volume reduction and treatment cost savings

  19. The glassy wormlike chain

    International Nuclear Information System (INIS)

    Kroy, Klaus; Glaser, Jens

    2007-01-01

    We introduce a new model for the dynamics of a wormlike chain (WLC) in an environment that gives rise to a rough free energy landscape, which we name the glassy WLC. It is obtained from the common WLC by an exponential stretching of the relaxation spectrum of its long-wavelength eigenmodes, controlled by a single parameter E. Predictions for pertinent observables such as the dynamic structure factor and the microrheological susceptibility exhibit the characteristics of soft glassy rheology and compare favourably with experimental data for reconstituted cytoskeletal networks and live cells. We speculate about the possible microscopic origin of the stretching, implications for the nonlinear rheology, and the potential physiological significance of our results

  20. Developing bulk exchange spring magnets

    Science.gov (United States)

    Mccall, Scott K.; Kuntz, Joshua D.

    2017-06-27

    A method of making a bulk exchange spring magnet by providing a magnetically soft material, providing a hard magnetic material, and producing a composite of said magnetically soft material and said hard magnetic material to make the bulk exchange spring magnet. The step of producing a composite of magnetically soft material and hard magnetic material is accomplished by electrophoretic deposition of the magnetically soft material and the hard magnetic material to make the bulk exchange spring magnet.

  1. Amorphous ferromagnetism and re-entrant magnetic glassiness in Sm{sub 2}Mo{sub 2}O{sub 7}

    Energy Technology Data Exchange (ETDEWEB)

    Prando, Giacomo; Wolter-Giraud, Anja [Leibniz-Institut fuer Festkoerper- und Werkstoffforschung (IFW) Dresden, D-01171 Dresden (Germany); Carretta, Pietro [Dipartimento di Fisica e Unita CNISM di Pavia, Universita di Pavia, I-27100 Pavia (Italy); Saint-Martin, Romuald; Revcolevschi, Alexandre [Laboratoire de Physico-Chimie de l' Etat Solide, ICMMO, UMR8182, Universite Paris-Sud, F-91405 Orsay (France); Buechner, Bernd [Leibniz-Institut fuer Festkoerper- und Werkstoffforschung (IFW) Dresden, D-01171 Dresden (Germany); Institut fuer Festkoerperphysik, Technische Universitaet Dresden, D-01062 Dresden (Germany)

    2015-07-01

    We report on the investigation of a high-quality single crystal of Sm{sub 2}Mo{sub 2}O{sub 7} by means of dc magnetometry, muon spin spectroscopy and high-harmonics ac susceptibility. The magnetic phase of the Mo{sup 4+} sublattice develops below T{sub C} = 78 K and is typically discussed in the literature as a conventional itinerant ferromagnetic state. However, our results clearly detect a complicated superposition of conventional and highly disordered magnetic behaviors below 78 K sharing several common features with amorphous ferromagnetic alloys and with other insulating spin-glass pyrochlore molybdates. As typical for amorphous ferromagnets, a freezing of the transverse XY spin components of Mo{sup 4+} below T ∝ 25 K is evidenced, an effect otherwise known as re-entrant spin-glass phase. Our results shed new light on the magnetic properties of Sm{sub 2}Mo{sub 2}O{sub 7} and on the overall electronic phase diagram commonly accepted for pyrochlore molybdates.

  2. Development of a voltammetric procedure for assay of the antihistamine drug hydroxyzine at a glassy carbon electrode: Quantification and pharmacokinetic studies.

    Science.gov (United States)

    Beltagi, A M; Abdallah, O M; Ghoneim, M M

    2008-01-15

    An electrochemical study of hydroxyzine at a glassy carbon electrode was carried out in the Britton-Robinson universal buffer of pH 2-11. Hydroxyzine was oxidized in a single two-electron irreversible process controlled mainly by adsorption. A simple, sensitive and time-saving square-wave adsorptive anodic stripping voltammetric procedure has been developed for determination of hydroxyzine in its commercial tablets and human serum without prior extraction. The optimized procedural conditions were: frequency=120Hz, scan increment=10mV, pulse-amplitude=25mV, accumulation potential=-0.3V, accumulation time=90-300s and a Britton-Robinson universal buffer of pH 4 as a supporting electrolyte. Mean recoveries of 100.5+/-0.71 and 98.6+/-1.12% (n=5) were achieved for assay of hydroxyzine in Atarax 10 and 25mg dosage forms, respectively. Limit of detection of 1.5x10(-8)molL(-1) (5.624ngmL(-1)) and limit of quantitation of 5.0x10(-8)molL(-1) (18.746ngmL(-1)) were achieved in human serum with a mean recovery of 98.4+/-1.22%, without prior extraction of the drug. Moreover, the described procedure was applied for evaluating the pharmacokinetic parameters of hydroxyzine in plasma of two healthy volunteers after administration of a single oral dose (Atarax)-25mg).

  3. Development of superconducting magnets for magnetically levitated trains

    International Nuclear Information System (INIS)

    Ohno, E.; Iwamoto, M.; Ogino, O.; Kawamura, T.

    1974-01-01

    Superconducting magnets will play a vital role in magnetically levitated trains, producing lift, guidance and propulsion forces. The main problems in the design are the current density of coils and the cryogenic thermal insulation. This paper describes the development of full-scale levitation magnets with length of 1.55m and width of 0.3 or 0.5m. Dynamic levitation tests using small model magnets are also presented. (author)

  4. Recent development in magnetic neutron scattering studies

    International Nuclear Information System (INIS)

    Endoh, Yasuo

    1993-01-01

    Neutron scattering results contain many new concepts in modern magnetism. We review here the most recent neutron magnetic scattering studies from so called '214' copper oxide lamellar materials, because a number of important developments in magnetism are condensed in this novel subject. We show that neutron scattering has played crucial role in our understanding of modern magnetism. (author)

  5. Feeding and development of the glassy-winged sharpshooter, Homalodisca vitripennis, on Australian native plant species and implications for Australian biosecurity.

    Directory of Open Access Journals (Sweden)

    Anna A Rathé

    Full Text Available In any insect invasion the presence or absence of suitable food and oviposition hosts in the invaded range is a key factor determining establishment success. The glassy-winged sharpshooter, Homalodisca vitripennis, is an important insect vector of the xylem-limited bacterial plant pathogen, Xylella fastidiosa, which causes disease in numerous host plants including food and feedstock crops, ornamentals and weeds. Both the pathogen and the vector are native to the Americas and are considered to be highly invasive. Neither has been detected in Australia. Twelve Australian native plant species present in the USA were observed over two years for suitability as H. vitripennis feeding, oviposition and nymph development hosts. Hosts providing evidence of adult or nymph presence were Leptospermum laevigatum, Acacia cowleana, Eremophila divaricata, Eucalyptus wandoo, Hakea laurina, Melaleuca laterita and Swainsona galegifolia. An oviposition-suitability field study was conducted with citrus, a favoured oviposition host, as a positive control. Citrus and L. laevigatum, A. cowleana, B. ericifolia×B. spinulosa, C. pulchella, E. divaricata, E. wandoo, H. laurina, and S. galegifolia were found to be oviposition hosts. Egg parasitism by the mymarid parasitoid Gonatocerus ashmeadi was observed on all Australian plants. A number of Australian plants that may facilitate H. vitripennis invasion have been identified and categorised as 'high risk' due to their ability to support all three life stages (egg, nymph and adult of the insect in the field (L. laevigatum, A. cowleana, E. divaricata, H. laurina, and S. galegifolia. The implications of these host status and natural enemy research findings are discussed and placed in an Australian invasion context.

  6. Development of portable superconducting bulk magnet system

    International Nuclear Information System (INIS)

    Saho, N.; Nishijima, N.; Tanaka, H.; Sasaki, A.

    2009-01-01

    Recently a magnetic drug delivery system (MDDS) has been developing to navigate magnetic seeded drugs around diseased parts of the human body. To improve the magnetic drug delivery performance, a portable high temperature superconducting (HTS) bulk magnet system with high magnetic fields has been developed. This magnet system mainly consists of small bulk high temperature superconductors and a compact cryocooler. The materials of the high temperature superconductor are rare earth 123 single domain compounds (Gd-Ba-Cu-O). The bulk magnet was activated successfully using field-cooling magnetization under the superconducting solenoid magnet. The magnetic flux densities at the surface of the vacuum chambers that contain bulk magnets reached 5.07 T and 6.76 T using the static magnetic fields of 6 T and 10 T superconducting solenoid magnets, respectively. A cryocooler cooled them to 38.1 K and 39.1 K. It was clarified that the magnetic gradient was approximately 10 T/m at a position located 50 mm from the surface of the vacuum chambers.

  7. Recent developments in hard magnetic bulk materials

    International Nuclear Information System (INIS)

    Fidler, Josef; Schrefl, Thomas; Hoefinger, Sabine; Hajduga, Maciej

    2004-01-01

    The importance of newly developed permanent magnetic materials in many electromechanical, magnetomechanical and electronic applications is attributed to the drastic improvement in microstructure related properties, such as the remanence, the magnetic energy density product and the coercive field. The influence of the microstructure on the magnetic properties of the magnets will be discussed, where special emphasis is laid on rare earth permanent magnets. Highest performance, anisotropic Nd-Fe-B magnets with J r >1.5 T (BH) max >450 kJm -3 and J H c > 750 kAm -1 , which are produced by the powder metallurgy route, show a strong influence of composition and processing parameters on the magnetic properties. The magnetic properties of Sm(Co,Cu,Fe,Zr) z sintered magnets, which are used nowadays for high temperature applications between 300 and 500 deg. C, are determined by the cellular precipitation microstructure, which is developed during a complex heat treatment and by the microchemistry. Special hard magnetic powder materials, such as Sm 2 Fe 17 N 3 and nanocrystalline, composite Nd 2 Fe 14 B /(α-Fe,Fe 3 B) materials have been developed especially for usage in bonded magnetic materials, which show the strongest annual increase in the production of permanent magnets. The phenomenon of the enhancement of remanence, occurring in single phase and composite Nd 2 Fe 14 B based magnets with isotropic grain alignment, is attributed to intergrain exchange interactions

  8. Magnetoresistance, electrical conductivity, and Hall effect of glassy carbon

    Energy Technology Data Exchange (ETDEWEB)

    Baker, D.F.

    1983-02-01

    These properties of glassy carbon heat treated for three hours between 1200 and 2700/sup 0/C were measured from 3 to 300/sup 0/K in magnetic fields up to 5 tesla. The magnetoresistance was generally negative and saturated with reciprocal temperature, but still increased as a function of magnetic field. The maximum negative magnetoresistance measured was 2.2% for 2700/sup 0/C material. Several models based on the negative magnetoresistance being proportional to the square of the magnetic moment were attempted; the best fit was obtained for the simplest model combining Curie and Pauli paramagnetism for heat treatments above 1600/sup 0/C. Positive magnetoresistance was found only in less than 1600/sup 0/C treated glassy carbon. The electrical conductivity, of the order of 200 (ohm-cm)/sup -1/ at room temperature, can be empirically written as sigma = A + Bexp(-CT/sup -1/4) - DT/sup -1/2. The Hall coefficient was independent of magnetic field, insensitive to temperature, but was a strong function of heat treatment temperature, crossing over from negative to positive at about 1700/sup 0/C and ranging from -0.048 to 0.126 cm/sup 3//coul. The idea of one-dimensional filaments in glassy carbon suggested by the electrical conductivity is compatible with the present consensus view of the microstructure.

  9. Water clustering in glassy polymers.

    Science.gov (United States)

    Davis, Eric M; Elabd, Yossef A

    2013-09-12

    In this study, water solubility and water clustering in several glassy polymers, including poly(methyl methacrylate) (PMMA), poly(styrene) (PS), and poly(vinylpyrrolidone) (PVP), were measured using both quartz spring microbalance (QSM) and Fourier transform infrared-attenuated total reflectance (FTIR-ATR) spectroscopy. Specifically, QSM was used to determine water solubility, while FTIR-ATR spectroscopy provided a direct, molecular-level measurement of water clustering. The Flory-Huggins theory was employed to obtain a measure of water-polymer interaction and water solubility, through both prediction and regression, where the theory failed to predict water solubility in both PMMA and PVP. Furthermore, a comparison of water clustering between direct FTIR-ATR spectroscopy measurements and predictions from the Zimm-Lundberg clustering analysis produced contradictory results. The failure of the Flory-Huggins theory and Zimm-Lundberg clustering analysis to describe water solubility and water clustering, respectively, in these glassy polymers is in part due to the equilibrium constraints under which these models are derived in contrast to the nonequilibrium state of glassy polymers. Additionally, FTIR-ATR spectroscopy results were compared to temperature-dependent diffusivity data, where a correlation between the activation energy for diffusion and the measured water clustering was observed.

  10. Broadband nanoindentation of glassy polymers: Part I Viscoelasticity

    Science.gov (United States)

    Joesph E. Jakes; Rod S. Lakes; Don S. Stone

    2012-01-01

    Protocols are developed to assess viscoelastic moduli from unloading slopes in Berkovich nanoindentation across four orders of magnitude in time scale (0.01-100 s unloading time). Measured viscoelastic moduli of glassy polymers poly(methyl methacrylate), polystyrene, and polycarbonate follow the same trends with frequency (1/unloading time) as viscoelastic moduli...

  11. Development of superconducting braid for accelerator magnets

    International Nuclear Information System (INIS)

    Sampson, W.B.

    1976-01-01

    Superconductors for use in the magnets of high energy particle accelerators have been under development at BNL since 1962. The first wide braided conductor was made in 1968 from single core NbTi wire. The conductor now used in the prototype ISABELLE magnets is a more sophisticated version of these early conductors. The large aspect ratio attainable with flat braids makes it possible to construct dipole and quadrupole magnets from a single layer of conductor, considerably simplifying their design. Magnets made from this type of conductor have performed excellently, exhibiting very little training and demonstrating a remarkable ability to quench without sustaining damage. The fabrication steps for braided conductor are described. Contracts have been negotiated for the industrial production of braided conductor and the first shipments of finished conductor are scheduled for delivery early in 1977. A multifilamentary Nb 3 Sn version of the conductor is also being developed and is described briefly

  12. Low temperature thermal conductivities of glassy carbons

    International Nuclear Information System (INIS)

    Anderson, A.C.

    1979-01-01

    The thermal conductivity of glassy carbon in the temperature range 0.1 to 100 0 K appears to depend only on the temperature at which the material was pyrolyzed. The thermal conductivity can be related to the microscopic structure of glassy carbon. The reticulated structure is especially useful for thermal isolation at cryogenic temperatures

  13. Development of HTS Magnet for Rotating Gantry

    Science.gov (United States)

    Tasaki, Kenji; Koyanagi, Kei; Takayama, S. Shigeki; Ishii, Yusuke; Kurusu, Tsutomu; Amemiya, Naoyuki; Ogitsu, Toru; iwata, Yoshiyuki; Noda, Koji

    The effectiveness of heavy-ion radiotherapy for cancer treatment has been recognized by medical experts and the public. However, due to the large size of the equipment, this therapy has not been widely adopted. In particular, the rotating gantries used to irradiate patients with the heavy-ion beams from any direction may be as heavy as 600 tons in our estimation. By employing high-temperature superconducting (HTS) wires in these rotating gantries and increasing the magnetic field generated by the deflecting coils, the total weight of the rotating gantry can be reduced to around the weight of those used for proton radiotherapy. A project for developing an HTS deflecting magnet for heavy-ion radiotherapy has been underway since 2013, supported by the Japanese Ministry of Economy, Trade and Industry (METI) and the Japan Agency for Medical Research and Development (AMED). The aim of this project is to develop fundamental technologies for designing and fabricating HTS deflecting magnets, such as irregular magnetic field estimating techniques, design technology for HTS magnets, high-precision HTS coil winding technology, AC loss estimating techniques, and thermal runaway estimating techniques and to fabricate a small model of an HTS deflecting magnet and evaluate its performance. In this paper, the project's progress will be described.

  14. Development of criteria for a magnetic hydrocyclones

    Directory of Open Access Journals (Sweden)

    Avdeyev Boris

    2017-01-01

    Full Text Available New criteria of a magnetic hydrocyclone - average value, magnetic field density and magnetic energy in a hydrocyclone are introduced in the article. Due to simplicity of a design and Ease of production and service, magnetic hydrocyclones have found broad application in virtually all sectors of industry, but more conspicuously advantages of their use reveal in purification systems of cooling lubricant while metal working. The dependence between field distribution in the working chamber and its average value hasn't been mathematically stated still. Complexity of criteria development and the determination of average value of the field is that the field strength changes depending on radius and height of the device. It is impossible to calculate the efficiency of cleaning from ferromagnetic impurity without knowledge of average value of magnetic field in the working chamber of a hydrocyclone therefore this problem is topical. The assumptions made in this paper are listed. Formulae are given, and numerical calculation of criteria of a hydrocyclone with radial magnetic field is shown by an example. Average value of the field, field density and magnetic energy in the working chamber of the device of inertial type has been defined on the basis of the dependence between field strength on the one hand both the radius and height of the field on the other hand which was obtained earlier.

  15. Recent developments in hard magnetic materials

    International Nuclear Information System (INIS)

    Asti, G.

    1989-01-01

    Hard magnetic materials find ever-increasing uses in modern technology. Their importance is mainly in the domain of permanent magnets, but a variety of other applications is being offered to this class of materials, especially for what regards the areas of information storage, telecommunications and special electronic devices. These developments are connected to the emphasis that is more and more given to thin films having high magnetic anisotropy. The recent advancement in the field of hard magnetic materials is among the best examples where technology depends to a great extent upon the continuous progress in the scientific knowledge. The research activity is characterized by the introduction of new classes of materials and continuous improvements in the preparation techniques both for what regards industrial processing and method for obtaining high quality materials in form of crystals, films or amorphous specimens. In this respect a special place must be reserved to rare earth transition metal compounds, a class of materials that attracted enormeous attention after the discovery by Hoffer and Strnat in 1966 of the large uniaxial magnetocrystalline anisotropy of the compound YCo 5 . Beside the so called 1:5 phase, other compositions of technical importance are the 2:17 and the recently discovered Nd 2 Fe 14 B, which is a real new ternary phase having tetragonal crystal structure. Great efforts have been done to gain a better understanding of the magnetic anisotropy and its relationship to the coercivity is of leading importance for a further development in this important area of magnetism. (orig.)

  16. Cooperative strings and glassy interfaces.

    Science.gov (United States)

    Salez, Thomas; Salez, Justin; Dalnoki-Veress, Kari; Raphaël, Elie; Forrest, James A

    2015-07-07

    We introduce a minimal theory of glass formation based on the ideas of molecular crowding and resultant string-like cooperative rearrangement, and address the effects of free interfaces. In the bulk case, we obtain a scaling expression for the number of particles taking part in cooperative strings, and we recover the Adam-Gibbs description of glassy dynamics. Then, by including thermal dilatation, the Vogel-Fulcher-Tammann relation is derived. Moreover, the random and string-like characters of the cooperative rearrangement allow us to predict a temperature-dependent expression for the cooperative length ξ of bulk relaxation. Finally, we explore the influence of sample boundaries when the system size becomes comparable to ξ. The theory is in agreement with measurements of the glass-transition temperature of thin polymer films, and allows quantification of the temperature-dependent thickness hm of the interfacial mobile layer.

  17. Development of sensitive amperometric hydrogen peroxide sensor using a CuNPs/MB/MWCNT-C{sub 60}-Cs-IL nanocomposite modified glassy carbon electrode

    Energy Technology Data Exchange (ETDEWEB)

    Roushani, Mahmoud, E-mail: mahmoudroushani@yahoo.com; Bakyas, Kobra; Zare Dizajdizi, Behruz

    2016-07-01

    A sensitive hydrogen peroxide (H{sub 2}O{sub 2}) sensor was constructed based on copper nanoparticles/methylene blue/multiwall carbon nanotubes–fullerene–chitosan–ionic liquid (CuNPs/MB/MWCNTs–C{sub 60}–Cs–IL) nanocomposites. The MB/MWCNTs–C{sub 60}–Cs–IL and CuNPs were modified glassy carbon electrode (GCE) by the physical adsorption and electrodeposition of copper nitrate solution, respectively. The physical morphology and chemical composition of the surface of modified electrode was investigated by scanning electron microscopy (SEM) and energy-dispersive X-ray spectroscopy (EDS), respectively. The electrochemical properties of CuNPs/MB/MWCNTs–C{sub 60}–Cs–IL/GCE were investigated by cyclic voltammetry (CV) and amperometry techniques and the sensor exhibited remarkably strong electrocatalytic activities toward the reduction of hydrogen peroxide. The peak currents possess a linear relationship with the concentration of H{sub 2}O{sub 2} in the range of 0.2 μM to 2.0 mM, and the detection limit is 55.0 nM (S/N = 3). In addition, the modified electrode was used to determine H{sub 2}O{sub 2} concentration in human blood serum sample with satisfactory results. - Highlights: • CuNPs/MB/MWCNT-C{sub 60}-Cs-IL/GC electrode was constructed by layer-by-layer method. • The catalytic performance of the sensor was studied with the use of amperometric technique. • The constructed sensor showed enhanced electrocatalytic activity toward the reduction of H{sub 2}O{sub 2}. • The CuNPs/MB/MWCNT-C{sub 60}-Cs-IL/GC electrode demonstrated high stability for the detection of H{sub 2}O{sub 2}.

  18. Superconductivity and magnetism: Materials properties and developments

    Energy Technology Data Exchange (ETDEWEB)

    Andersen, N.H.; Bay, N.; Grivel, J.C. (eds.) [and others

    2003-07-01

    The 24th Risoe International Symposium on Materials Science focuses on development of new materials, devices and applications, as well as experimental and theoretical studies of novel and unexplained phenomena in superconductivity and magnetism, e.g. within high.T{sub c} superconductivity, magnetic superconductors, MgB{sub 2}, CMR materials, nanomagnetism and spin-tronics. The aim is to stimulate exchange of ideas and establish new collaborations between leading Danish and international scientists. The topics are addressed by presentations from 24 invited speakers and by 41 contributed papers. (ln)

  19. Recent developments in magnetic resonance imaging

    International Nuclear Information System (INIS)

    Ugurbil, K.

    1995-01-01

    Magnetic resonance imaging permits the visualization of anatomical structures in the living human brain with unprecedented spatial resolution and contrast. Recent developments, however, not only significantly improved anatomical imaging but have also added totally new and novel dimensions to MR imaging, namely the ability to measure and image functional, physiological, and metabolic parameters in the human brain. These applications are ultimately limited by signal-to-noise ratio of the MR methodology and therefore are helped by the recent introduction of high magnetic fields for the use of human studies

  20. Superconductivity and magnetism: Materials properties and developments

    International Nuclear Information System (INIS)

    Andersen, N.H.; Bay, N.; Grivel, J.C.

    2003-01-01

    The 24th Risoe International Symposium on Materials Science focuses on development of new materials, devices and applications, as well as experimental and theoretical studies of novel and unexplained phenomena in superconductivity and magnetism, e.g. within high.T c superconductivity, magnetic superconductors, MgB 2 , CMR materials, nanomagnetism and spin-tronics. The aim is to stimulate exchange of ideas and establish new collaborations between leading Danish and international scientists. The topics are addressed by presentations from 24 invited speakers and by 41 contributed papers. (ln)

  1. Development of magnetic drug delivery system using HTS bulk magnet

    International Nuclear Information System (INIS)

    Terada, T.; Fukui, S.; Mishima, F.; Akiyama, Y.; Izumi, Y.; Nishijima, S.

    2008-01-01

    Magnetic drug delivery system (MDDS) is the method which the magnetic seeded drug is injected into a blood vessel and then controlled and accumulated by a magnet located outside of the human body. A high accumulation efficiency of the drug to a local diseased part and reduction in side-effects to normal organs are expected by using MDDS. The most important element in MDDS is a magnetic field generator. The high temperature superconducting (HTS) bulk magnet which can generate high magnetic field and magnetic field gradient extending to a point distant from the magnet in several ten millimeters is necessary to achieve the MDDS. In this study, the computer simulation and model experiment were conducted in order to confirm the applicability of MDDS to ovary of the cow body

  2. Development of magnetic jxB sensor

    International Nuclear Information System (INIS)

    Kasai, Satoshi; Ishitsuka, Etsuo

    2001-12-01

    The improved mechanical sensor, i.e. magnetic jxB sensor (a mechanical sensor and a part of the steady state hybrid-type magnetic sensor) has been designed. The basic structure of the sensor is similar to the previously developed sensor (old sensor) in EDA phase. In this design, the neutron resistant materials are selected for the load cell (strain gauge and sensor beam) and sensing coil/frame. In order to reduce temperature drift of the sensor signal, four strain gauges with the same electrical property and geometrical size are bonded on the sensor beam by using Al 2 O 3 plasma spraying process, i.e., a couple of strain gauges is bonded on one side of the beam and another couple of gauges is bonded on the other side. These four strain gauges form an electrical bridge circuit. The zero-level drift of the output of the load cell used in the magnetic jxB sensor was reduced to about 1/20 compared with the old sensor. The temperature dependence of the output of the load cell is small. The linearity of the output of the load cell against weight was obtained. A non-linearity was observed in the sensitivity of the magnetic jxB sensor. The deviation of sensitivity from the fitting line was less than 7% in the high magnetic field region. The neutron irradiation effect on sensitivity of the sensor was investigated. The sensitivity of the sensor was gradually decreased by ∼30% at neutron fluence of (1.8-2.8)x10 23 n/m 2 in the high magnetic field. During irradiation, the non-linearity was observed in the sensitivity. (author)

  3. Glassy states in fermionic systems with strong disorder and interactions

    Science.gov (United States)

    Schwab, David J.; Chakravarty, Sudip

    2009-03-01

    We study the competition between interactions and disorder in two dimensions. Whereas a noninteracting system is always Anderson localized by disorder in two dimensions, a pure system can develop a Mott gap for sufficiently strong interactions. Within a simple model, with short-ranged repulsive interactions, we show that, even in the limit of strong interaction, the Mott gap is completely washed out by disorder for an infinite system for dimensions D≤2 , leading to a glassy state. Moreover, the Mott insulator cannot maintain a broken symmetry in the presence of disorder. We then show that the probability of a nonzero gap as a function of system size falls onto a universal curve, reflecting the glassy dynamics. An analytic calculation is also presented in one dimension that provides further insight into the nature of slow dynamics.

  4. Development of a novel rotary magnetic refrigerator

    DEFF Research Database (Denmark)

    Lozano, Jaime A.; Capovilla, Matheus S.; Trevizoli, Paulo V.

    2016-01-01

    with approximately 1.7 kg of gadolinium spheres (425-600 μm diameter) were placed in the magnetic gap. Two low-friction rotary valves were developed to synchronize the hydraulic and magnetic cycles. The valves were positioned at the hot end to avoid heat generation in the cold end. In this work, experimental results...... are presented as a function of the operating frequency, fluid flow rate, hot reservoir temperature and thermal load. The performance of the device was evaluated in terms of the coefficient of performance (COP) and overall second-law efficiency (η2nd). The maximum no-load temperature span was 12 K at 1.5 Hz...

  5. Adhesion in hydrogels and model glassy polymers

    Science.gov (United States)

    Guvendiren, Murat

    Two main topics are addressed in this dissertation: (1) adhesion in hydrogels; (2) interfacial interactions between model glassy polymers. A self-assembly technique for the formation of hydrogels from acrylic triblock copolymer solutions was developed, based on vapor phase solvent exchange. Structure formation in the gels was characterized by small angle X-ray scattering, and swelling was measured in controlled pH buffer solutions. Strong gels are formed with polymer weight fractions between 0.01 and 0.15, and with shear moduli between 0.6 kPa and 3.5 kPa. Adhesive functionality, based on 3,4-dihydroxy-L-phenylalanine (DOPA) was also incorporated into the triblock copolymers. The effect of DOPA concentration on gel formation and swelling was investigated in detail. The adhesive properties of DOPA-functionalized hydrogels on TiO2 were investigated with an axisymmetric adhesion method. It was shown that the presence of DOPA enhances the adhesive properties of the hydrogels, but that the effect is minimized at pH values below 10, where the DOPA groups are hydrophobic. Thin film membranes were produced in order to study the specific interactions between DOPA and TiO2 and DOPA and tissue, using a membrane inflation method. The presence of DOPA in the membranes enhances the adhesion on TiO 2 and tissue, although adhesion to tissue requires that the DOPA groups be oxidized while in contact with the tissue of interest. Porous hydrogel scaffolds for tissue engineering applications were formed by adding salt crystals to the triblock copolymer solution prior to solvent exchange. Salt was then leached out by immersing the gel into water. Structures of the porous hydrogels were characterized by confocal laser scanning microscopy. These hydrogels were shown to be suitable for tissue regeneration and drug delivery applications. Diffusion-mediated adhesion between two component miscible polymer systems having very different glassy temperatures was also investigated. Axisymmetric

  6. Stability and quench development study in small HTSC magnet

    NARCIS (Netherlands)

    Ilyin, Y.; Vysotski, V.S.; Kiss, T.; Takeo, M.; Okamoto, H.; Irie, F.

    2001-01-01

    Stability and quench development in a HTSC magnet have been experimentally studied with the transport current in the magnet being below or above the “thermal quench current” level. The magnet was tested at both cryocooler cooling and liquid nitrogen cooling, with and without background magnetic

  7. Development of superconducting magnet systems for HIFExperiments

    Energy Technology Data Exchange (ETDEWEB)

    Sabbi, Gian Luca; Faltens, A.; Leitzke, A.; Seidl, P.; Lund, S.; Martovets ky, N.; Chiesa, L.; Gung, C.; Minervini, J.; Schultz, J.; Goodzeit, C.; Hwang, P.; Hinson, W.; Meinke, R.

    2004-07-27

    The U.S. Heavy Ion Fusion program is developing superconducting focusing quadrupoles for near-term experiments and future driver accelerators. Following the fabrication and testing of several models, a baseline quadrupole design was selected and further optimized. The first prototype of the optimized design achieved a conductor-limited gradient of 132 T/m in a 70 mm bore, with measured field harmonics within 10 parts in 10{sup 4}. In parallel, a compact focusing doublet was fabricated and tested using two of the first-generation quadrupoles. After assembly in the cryostat, both magnets reached their conductor-limited quench current. Further optimization steps are currently underway to improve the performance of the magnet system and reduce its cost. They include the fabrication and testing of a new prototype quadrupole with reduced field errors as well as improvements of the cryostat design for the focusing doublet. The prototype units will be installed in the HCX beamline at LBNL, to perform accelerator physics experiments and gain operational experience. Successful results in the present phase will make superconducting magnets a viable option for the next generation of integrated beam experiments.

  8. The Development Prospects of Magnetically Levitated Trains

    Directory of Open Access Journals (Sweden)

    Mladen Nikšić

    2012-10-01

    Full Text Available The paper analyses the up-to-date research in developingmagnetically levitated (MAGLEV motorcars. It presents thehistorical overview of the development of the most famousmagnetic levitation systems of today.Apart from describing the operation method and the technicalfeatures of each system, the paper ana(vses the advantagesand drawbacks of certain systems, as well as the advantagesand drawbacks of magnetically levitated motorcars comparedto conventional railway.The paper presents the plans for the future as well as the systemswhich have the highest prospects of being also commerciallyand not just experimentally used.

  9. Enhancement of the efficiency of magnetic targeting for drug delivery: Development and evaluation of magnet system

    International Nuclear Information System (INIS)

    Cao Quanliang; Han Xiaotao; Li Liang

    2011-01-01

    Deep magnetic capture and clinical application are the current trends for magnetic targeted drug delivery system. More promising and possible strategies are needed to overcome the current limitations and further improve the magnetic targeting technique. Recent advances in the development of targeting magnet system show promise in progressing this technology from the laboratory to the clinic. Starting from well-known basic concepts, current limitations of magnetic targeted drug delivery system are analyzed. Meanwhile, the design concepts and evaluations of some effective improvements in magnet system are discussed and reviewed with reference to (i) reasonable design of magnet system; (ii) control modes of magnet system used to generate dynamical magnetic fields; and (iii) magnetic field driving types. - Research Highlights: → The current limitations of MTDDS for deep capture and clinical application are analyzed. → The development of magnet system shows promise in progressing MTDDS to clinical application. → The design concepts and evaluations of improvements in magnet system are reviewed and discussed. → The key to improve magnet system lies in controllable magnets and different excitations.

  10. NITROANILINE FILM-HOLE MODIFIED GLASSY CARBON ...

    African Journals Online (AJOL)

    ABSTRACT. Herein, we report determination of dopamine (DA) at modified glassy carbon electrode (GCE) with a film produced by reduction of diazonium generated from p-nitroaniline (PNA). Pores were created purposely by stripping pre-deposited gold nanoparticles (AuNPs) in the modifier film. The modified electrodes.

  11. Glassy carbon electrodes modified with gelatin functionalized ...

    Indian Academy of Sciences (India)

    Home; Journals; Bulletin of Materials Science; Volume 38; Issue 7. Glassy carbon electrodes modified with gelatin functionalized reduced graphene oxide nanosheet for determination of gallic acid. Fereshteh Chekin Samira Bagheri Sharifah Bee Abd Hamid. Volume 38 Issue 7 December 2015 pp 1711-1716 ...

  12. mwnts composite film modified glassy carbon electrode

    African Journals Online (AJOL)

    Preferred Customer

    ABSTRACT: A poly p-aminosalicylic acid (Poly(p-ASA)) and multiwall carbon nanotubes. (MWCNTs) composite modified glassy carbon (GC) electrode was constructed by casting the MWNTs on the GC electrode surface followed by electropolymerization of the p-ASA on the MWCNTs/GCE. The electrochemical behaviours ...

  13. Development of magnets for agricultural radiation processing facility at RRCAT

    International Nuclear Information System (INIS)

    Malik, R.; Sreeramulu, K.; Ruwali, K.

    2015-01-01

    A 10 MeV, 5 kW electron Linac based Agricultural Radiation Processing Facility is being set-up near DABH Vegetable and Fruit Market, Indore. In this paper the design and development of a set of solenoid and scanning magnets required for the Linac is presented. The solenoid magnets include small aperture (22 mm diameter) beam collimator magnet and other water cooled solenoid magnets of peak fields of 1200 Gauss and 500 Gauss to be placed around the Linac assembly between the RF couplers to improve beam transmission. The beam collimator magnet has been designed for an axial peak magnetic field of 410 Gauss and will be placed after the electron gun and before the Linac. The scanning magnet has been designed for maximum field strength of 436 Gauss for wider scanning of the electron beam. The cross-section of all the solenoid magnets were determined by computing the field distribution with the 2D magneto static POISSON code and 3D calculations were performed using OPERA 3D Code. The forces between the water cooled solenoids are also estimated since all the solenoid magnets are placed near to each other around the Linac assembly structure. The water cooled solenoids were made from hollow copper conductors and shielded around them with low carbon steel sheets. The magnet cores of collimators were manufactured from low carbon steel and coils from enameled copper wires. The scanning magnet core cross-section is of C-type, fabricated from 0.5 mm silicon steel laminations and coils from enameled copper wires. All the wound magnet coils were epoxy resin impregnated under vacuum and assembled with magnet cores. The magnetic field measurements of all the magnets were carried out using Hall probe. After field measurements, all the magnetic elements have been installed in the Linac assembly. The details of magnetic design, magnet development and the magnetic measurements will be discussed in this paper. (author)

  14. Development of a magnetic quartz crystal microbalance

    International Nuclear Information System (INIS)

    Yu, George Y.; Hunt, William D.; Josowicz, Mira; Janata, Jiri

    2007-01-01

    A new technique for measurement of magnetic properties of materials is demonstrated. It can be used for the measurement of thin magnetic films during their chemical modification. The resonance frequency of a quartz crystal microbalance (QCM) with conducting polymer (polyaniline) suspension in poly(ethylene glycol) was observed to increase with increasing the externally applied uniform dc magnetic field. Slowly sweeping the magnetic field between 0 and 3.1 T results in a frequency-field response curve. Chemical doping was done by exposing the polyaniline-emeraldine base film to HCl vapor. The change in population of free spins is reflected in increased frequency-field curve magnitude after HCl doping. Two working hypotheses explaining this observation are offered to explain how frequency of QCM with deposited magnetic film shifts with increasing intensity of the magnetic field

  15. A Stress Update Algorithm for Constitutive Models of Glassy Polymers

    Science.gov (United States)

    Danielsson, Mats

    2013-06-01

    A semi-implicit stress update algorithm is developed for the elastic-viscoplastic behavior of glassy polymers. The case of near rate-insensitivity is addressed, and the stress update algorithm is designed to handle this case robustly. A consistent tangent stiffness matrix is derived based on a full linearization of the internal virtual work. The stress update algorithm and (a slightly modified) tangent stiffness matrix are implemented in a commercial finite element program. The stress update algorithm is tested on a large boundary value problem for illustrative purposes.

  16. Development of Magnetic Nanomaterials and Devices for Biological Applications

    National Research Council Canada - National Science Library

    O'Connor, Charles J; Hormes, Josef; Bazan, Nicolas

    2007-01-01

    .... Novel bio-compatible ferrofluids of functionalized magnetic nanoparticles suitable for bioconjugation of antibodies or other active biomolecules are developed, prepared, and tested for use in bio...

  17. Orbital physics in sulfur spinels: ordered, liquid and glassy ground states

    International Nuclear Information System (INIS)

    Buettgen, N; Hemberger, J; Fritsch, V; Krimmel, A; Muecksch, M; Nidda, H-A Krug von; Lunkenheimer, P; Fichtl, R; Tsurkan, V; Loidl, A

    2004-01-01

    Measurements of magnetization M(T, H), heat capacity C(T), NMR lineshift K(T) and linewidth Δ(T), neutron scattering S(Q, ω, T) and broadband dielectric spectroscopy ε(ω, T) provide experimental evidence of the different orbital ground states in the cubic sulfur spinels under investigation. In all compounds, the tetrahedrally coordinated Jahn-Teller ions Fe 2+ are characterized by a degeneracy of the orbital degrees of freedom. Particularly, we found a long-range orbital ordering in polycrystalline (PC) FeCr 2 S 4 , and a glassy freezing of the orbital degrees of freedom in FeCr 2 S 4 (single crystals) (SCs). In contrast, FeSc 2 S 4 belongs to the rare class of spin-orbital liquids, where quantum fluctuations accompanying the glassy freezing of the orbitals suppress long-range magnetic order

  18. Thermonuclear reactor materials composed of glassy carbons

    International Nuclear Information System (INIS)

    Kazumata, Yukio.

    1979-01-01

    Purpose: To improve the durability to plasma radiation by the use of glassy carbon as the structural materials for the first wall and the blanket in thermonuclear devices. Constitution: The glassy carbon (glass-like carbon) is obtained by forming specific organic substances into a predetermined configuration and carbonizing them by heat decomposition under special conditions. They are impermeable carbon material of 1.40 - 1.70 specific gravity, less graphitizable and being almost in isotropic crystal forms in which isotropic structure such as in graphite is scarcely observed. They have an extremely high hardness, are less likely to be damaged when exposed to radiation and have great strength and corrosion resistance. Accordingly, the service life of the reactor walls and the likes can remarkably be increased by using the materials. (Horiuchi, T.)

  19. Wafer-level microstructuring of glassy carbon

    Science.gov (United States)

    Hans, Loïc. E.; Prater, Karin; Kilchoer, Cédric; Scharf, Toralf; Herzig, Hans Peter; Hermerschmidt, Andreas

    2014-03-01

    Glassy carbon is used nowadays for a variety of applications because of its mechanical strength, thermal stability and non-sticking adhesion properties. One application is glass molding that allows to realize high resolution diffractive optical elements on large areas and at affordable price appropriate for mass production. We study glassy carbon microstructuring for future precision compression molding of low and high glass-transition temperature. For applications in optics the uniformity, surface roughness, edge definition and lateral resolution are very important parameters for a stamp and the final product. We study different methods of microstructuring of glassy carbon by etching and milling. Reactive ion etching with different protection layers such as photoresists, aluminium and titanium hard masks have been performed and will be compare with Ion beam etching. We comment on the quality of the structure definition and give process details as well as drawbacks for the different methods. In our fabrications we were able to realize optically flat diffractive structures with slope angles of 80° at typical feature sizes of 5 micron and 700 nm depth qualified for high precision glass molding.

  20. A Thermodynamic Theory of Solid Viscoelasticity. Part 3: Nonlinear Glassy Viscoelasticity, Stability Constraints, Specifications

    Science.gov (United States)

    Freed, Alan; Leonov, Arkady I.

    2002-01-01

    This paper, the last in the series, continues developing the nonlinear constitutive relations for non-isothermal, compressible, solid viscoelasticity. We initially discuss a single integral approach, more suitable for the glassy state of rubber-like materials, with basic functionals involved in the thermodynamic description for this type of viscoelasticity. Then we switch our attention to analyzing stability constraints, imposed on the general formulation of the nonlinear theory of solid viscoelasticity. Finally, we discuss specific (known from the literature or new) expressions for material functions that are involved in the constitutive formulations of both the rubber-like and glassy-like, complementary parts of the theory.

  1. Development of magnetic drive packless valves for commercial purpose

    International Nuclear Information System (INIS)

    Hwang, Sung Tai; Choi, J. H.; Jeong, K. C.; Jeong, J. Y.; Choi, Y. D.; Kwon, S. W.; Kim, B. H.

    1997-01-01

    A study on development of magnetic drive packless valves for commercial purpose showed the results as follows: 1) characteristics and principle of the valve 2) study on the radial rays effecting to the permanent magnets 3) effects of temperature on the magnetic driving device a) temperature-dependency of the Nd-casting magnets b) effects of temperature on the heat releasing fins of high-temperature valve 4) optimization of torque a) arranging method of permanent magnets b) measuring method and results of torque 5) enlargement of magnetic rotating force a) experiments for the torque enlargement 6) calculation and pressure test for the pressure-resisting structure of magnetic power transmitting device a) calculation for the flat circular plates under pressure b) pressure test of the separating plate 7) design and manufacture of the valve 8) patent application. (author). 1 ref., 18 tabs., 38 figs

  2. The development of compact magnetic quadrupoles for ILSE

    International Nuclear Information System (INIS)

    Faltens, A.; Mukherjee, S.; Brady, V.

    1990-08-01

    Magnetic focussing is selected for the 4 MeV to 10 MeV section of the Induction Linac Systems Experiments (ILSE) to study the transport of magnetically focussed spacecharge-dominated beams and to explore the engineering problems in accurate positioning of the magnetic fields in an array of quadrupoles. A prototype development program for such magnets is currently under way. A compact design was selected to decrease the overall accelerator diameter and its cost. The design evolved from a cosine 2θ current distribution, corrected for end effects. Current-dominated magnets are used in a pulsed mode to allow higher current densities compared to standard dc water-cooled conductors. The POISSON and MAFCO codes were used in the design of the magnets. The construction of the quadrupoles is aimed at achieving location accuracy of the magnetic center to within 1 mil (2.54 x 10 -5 m) of the mechanical center

  3. Development of a boundary magnetic charge method for computing magnetic fields in a system containing saturated magnetic materials

    Energy Technology Data Exchange (ETDEWEB)

    Murata, H., E-mail: hkmurata@meijo-u.ac.jp; Ishigami, M.; Shimoyama, H.

    2016-01-11

    In previous research, we developed a three-dimensional (3D) boundary magnetic charge method (BMCM) for high-accuracy field calculations in a static magnetic field, even when there exist great differences between the magnitudes of permeability between neighboring magnetic materials. This method, however, cannot be applied to a system that contains saturated magnetic materials. In the present study, therefore, we have developed a novel method that addresses this issue. According to this new method, we divide the region containing the magnetic material into small-volume elements and divide the boundaries between neighboring small-volume elements into small-surface elements, assigning each element an appropriate initial value of permeability. The magnetic field inside and outside of the magnetic material is calculated using this permeability. The value of the permeability of each element is iteratively updated using μ–H data. The updated value of the permeability after the i-th iteration, μ{sub i}, is compared with that of the previous value, μ{sub i−1}. If the difference between the two values is within a preset range, the iteration process is judged to have converged and the value of μ{sub i} is regarded as the final converged value of the permeability. The magnetic field at an arbitrary point in space and/or inside the body of the magnetic material is calculated from the converged permeability of each element. As a result, we have succeeded in developing a novel BMCM for the calculation of a static magnetic field with high accuracy in a system containing saturated magnetic materials.

  4. The U.S. Magnet Development Program Plan

    CERN Document Server

    Gourlay, Stephen; Zlobin, Alexander; Cooley, Lance; Larbalestier, David

    2016-01-01

    The 2014 Particle Physics Project Prioritization Panel (P5) Report identified a critical need for transformational high field magnet R&D focused on substantially increasing performance and lowering the cost per T-m. This need was subsequently reiterated in the HEPAP* Accelerator R&D subpanel report. In response, the DOE Office of High Energy Physics has initiated an ambitious program, coordinated by LBNL (see Appendix A), to aggressively pursue the development of superconducting accelerator magnets that operate as closely as possible to the fundamental limits of superconducting materials and at the same time minimize or eliminate magnet training. The U.S. Magnet Development Program (MDP) is based on four goals that summarize the P5 and Subpanel recommendations. These goals will be achieved by focusing on high field dipole development along four elements. The first element aims at the establishment of a baseline design to demonstrate feasibility of 16 T magnets and the development of higher risk innova...

  5. Development of magnetic order in superconducting systems

    International Nuclear Information System (INIS)

    Moncton, D.E.; Shirane, G.; Thomlinson, W.

    1979-08-01

    Two different classes of rare-earth (RE) ternary superconductors (RERh 4 B 4 and REMo 6 S 8 , X=S, Se) have provided the first instances in which chemically ordered sublattices of magnetic ions exist in superconductors. Neutron scattering studies show that simple, conventional antiferromagnetism coexists with superconductivity in a number of systems, while destruction of superconductivity occurs with the onset of ferromagnetism. The magnetic structural details are summarized for the coexistent antiferromagnets, and review measurements on the superconducting → ferromagnetic transition in ErRh 4 B 4

  6. [Development of RF coil of permanent magnet mini-magnetic resonance imager and mouse imaging experiments].

    Science.gov (United States)

    Hou, Shulian; Xie, Huantong; Chen, Wei; Wang, Guangxin; Zhao, Qiang; Li, Shiyu

    2014-10-01

    In the development of radio frequency (RF) coils for better quality of the mini-type permanent magnetic resonance imager for using in the small animal imaging, the solenoid RF coil has a special advantage for permanent magnetic system based on analyses of various types.of RF coils. However, it is not satisfied for imaging if the RF coils are directly used. By theoretical analyses of the magnetic field properties produced from the solenoid coil, the research direction was determined by careful studies to raise further the uniformity of the magnetic field coil, receiving coil sensitivity for signals and signal-to-noise ratio (SNR). The method had certain advantages and avoided some shortcomings of the other different coil types, such as, birdcage coil, saddle shaped coil and phased array coil by using the alloy materials (from our own patent). The RF coils were designed, developed and made for keeled applicable to permanent magnet-type magnetic resonance imager, multi-coil combination-type, single-channel overall RF receiving coil, and applied for a patent. Mounted on three instruments (25 mm aperture, with main magnetic field strength of 0.5 T or 1.5 T, and 50 mm aperture, with main magnetic field strength of 0.48 T), we performed experiments with mice, rats, and nude mice bearing tumors. The experimental results indicated that the RF receiving coil was fully applicable to the permanent magnet-type imaging system.

  7. DEVELOPMENT AN APPATATUS IS FOR MAGNETIC THERAPY

    Directory of Open Access Journals (Sweden)

    М. M. Baran

    2012-12-01

    Full Text Available A new apparatus for magnetic therapy – magnetostimulator MS-2012 is described. A description of the functional scheme of the device is precented. Feature of the device is the usage of a microcontroller, which allows you to set the pulses of any frequency, shape (porosity, and allows independent channels control.

  8. Spatially heterogeneous ages in glassy dynamics

    International Nuclear Information System (INIS)

    Castillo, Horacio E.; Chamon, Claudio Chamon; Cugliandolo, Leticia F.; Iguain, Jose Luis; Kennett, Malcolm P.

    2003-09-01

    We construct a framework for the study of fluctuations in the nonequilibrium relaxation of glassy systems with and without quenched disorder. We study two types of two-time local correlators with the aim of characterizing the heterogeneous evolution in these systems: in one case we average the local correlators over histories of the thermal noise, in the other case we simply coarse-grain the local correlators obtained for a given noise realization. We explain why the noise-averaged correlators describe the fingerprint of quenched disorder when it exists, while the coarse-grained correlators are linked to noise-induced mesoscopic fluctuations. We predict constraints on the distribution of the fluctuations of the coarse-grained quantities. In particular, we show that locally defined correlations and responses are connected by a generalized local out-of-equilibrium fluctuation-dissipation relation. We argue that large size heterogeneities in the age of the system survive in the long-time limit. A symmetry of the underlying theory, namely invariance under reparametrizations of the time coordinates, underlies these results. We establish a connection between the probabilities of spatial distributions of local coarse-grained quantities and the theory of dynamic random manifolds. We define, and discuss the behavior of, a two-time dependent correlation length from the spatial decay of the fluctuations in the two-time local functions. We characterize the fluctuations in the system in terms of their fractal properties. For concreteness, we present numerical tests performed on disordered spin models in finite and infinite dimensions. Finally, we explain how these ideas can be applied to the analysis of the dynamics of other glassy systems that can be either spin models without disorder or atomic and molecular glassy systems. (author)

  9. Towards developing a compact model for magnetization switching in straintronics magnetic random access memory devices

    Science.gov (United States)

    Barangi, Mahmood; Erementchouk, Mikhail; Mazumder, Pinaki

    2016-08-01

    Strain-mediated magnetization switching in a magnetic tunneling junction (MTJ) by exploiting a combination of piezoelectricity and magnetostriction has been proposed as an energy efficient alternative to spin transfer torque (STT) and field induced magnetization switching methods in MTJ-based magnetic random access memories (MRAM). Theoretical studies have shown the inherent advantages of strain-assisted switching, and the dynamic response of the magnetization has been modeled using the Landau-Lifshitz-Gilbert (LLG) equation. However, an attempt to use LLG for simulating dynamics of individual elements in large-scale simulations of multi-megabyte straintronics MRAM leads to extremely time-consuming calculations. Hence, a compact analytical solution, predicting the flipping delay of the magnetization vector in the nanomagnet under stress, combined with a liberal approximation of the LLG dynamics in the straintronics MTJ, can lead to a simplified model of the device suited for fast large-scale simulations of multi-megabyte straintronics MRAMs. In this work, a tensor-based approach is developed to study the dynamic behavior of the stressed nanomagnet. First, using the developed method, the effect of stress on the switching behavior of the magnetization is investigated to realize the margins between the underdamped and overdamped regimes. The latter helps the designer realize the oscillatory behavior of the magnetization when settling along the minor axis, and the dependency of oscillations on the stress level and the damping factor. Next, a theoretical model to predict the flipping delay of the magnetization vector is developed and tested against LLG-based numerical simulations to confirm the accuracy of findings. Lastly, the obtained delay is incorporated into the approximate solutions of the LLG dynamics, in order to create a compact model to liberally and quickly simulate the magnetization dynamics of the MTJ under stress. Using the developed delay equation, the

  10. Towards developing a compact model for magnetization switching in straintronics magnetic random access memory devices

    Energy Technology Data Exchange (ETDEWEB)

    Barangi, Mahmood, E-mail: barangi@umich.edu; Erementchouk, Mikhail; Mazumder, Pinaki [Department of Electrical Engineering and Computer Science, University of Michigan, Ann Arbor, Michigan 48109-2121 (United States)

    2016-08-21

    Strain-mediated magnetization switching in a magnetic tunneling junction (MTJ) by exploiting a combination of piezoelectricity and magnetostriction has been proposed as an energy efficient alternative to spin transfer torque (STT) and field induced magnetization switching methods in MTJ-based magnetic random access memories (MRAM). Theoretical studies have shown the inherent advantages of strain-assisted switching, and the dynamic response of the magnetization has been modeled using the Landau-Lifshitz-Gilbert (LLG) equation. However, an attempt to use LLG for simulating dynamics of individual elements in large-scale simulations of multi-megabyte straintronics MRAM leads to extremely time-consuming calculations. Hence, a compact analytical solution, predicting the flipping delay of the magnetization vector in the nanomagnet under stress, combined with a liberal approximation of the LLG dynamics in the straintronics MTJ, can lead to a simplified model of the device suited for fast large-scale simulations of multi-megabyte straintronics MRAMs. In this work, a tensor-based approach is developed to study the dynamic behavior of the stressed nanomagnet. First, using the developed method, the effect of stress on the switching behavior of the magnetization is investigated to realize the margins between the underdamped and overdamped regimes. The latter helps the designer realize the oscillatory behavior of the magnetization when settling along the minor axis, and the dependency of oscillations on the stress level and the damping factor. Next, a theoretical model to predict the flipping delay of the magnetization vector is developed and tested against LLG-based numerical simulations to confirm the accuracy of findings. Lastly, the obtained delay is incorporated into the approximate solutions of the LLG dynamics, in order to create a compact model to liberally and quickly simulate the magnetization dynamics of the MTJ under stress. Using the developed delay equation, the

  11. Towards developing a compact model for magnetization switching in straintronics magnetic random access memory devices

    International Nuclear Information System (INIS)

    Barangi, Mahmood; Erementchouk, Mikhail; Mazumder, Pinaki

    2016-01-01

    Strain-mediated magnetization switching in a magnetic tunneling junction (MTJ) by exploiting a combination of piezoelectricity and magnetostriction has been proposed as an energy efficient alternative to spin transfer torque (STT) and field induced magnetization switching methods in MTJ-based magnetic random access memories (MRAM). Theoretical studies have shown the inherent advantages of strain-assisted switching, and the dynamic response of the magnetization has been modeled using the Landau-Lifshitz-Gilbert (LLG) equation. However, an attempt to use LLG for simulating dynamics of individual elements in large-scale simulations of multi-megabyte straintronics MRAM leads to extremely time-consuming calculations. Hence, a compact analytical solution, predicting the flipping delay of the magnetization vector in the nanomagnet under stress, combined with a liberal approximation of the LLG dynamics in the straintronics MTJ, can lead to a simplified model of the device suited for fast large-scale simulations of multi-megabyte straintronics MRAMs. In this work, a tensor-based approach is developed to study the dynamic behavior of the stressed nanomagnet. First, using the developed method, the effect of stress on the switching behavior of the magnetization is investigated to realize the margins between the underdamped and overdamped regimes. The latter helps the designer realize the oscillatory behavior of the magnetization when settling along the minor axis, and the dependency of oscillations on the stress level and the damping factor. Next, a theoretical model to predict the flipping delay of the magnetization vector is developed and tested against LLG-based numerical simulations to confirm the accuracy of findings. Lastly, the obtained delay is incorporated into the approximate solutions of the LLG dynamics, in order to create a compact model to liberally and quickly simulate the magnetization dynamics of the MTJ under stress. Using the developed delay equation, the

  12. Development and Testing of an Axial Halbach Magnetic Bearing

    Science.gov (United States)

    Eichenberg, Dennis J.; Gallo, Christopher A.; Thompson, William K.

    2006-01-01

    The NASA Glenn Research Center has developed and tested a revolutionary Axial Halbach Magnetic Bearing. The objective of this work is to develop a viable non-contact magnetic thrust bearing utilizing Halbach arrays for all-electric flight, and many other applications. This concept will help to reduce harmful emissions, reduce the Nation s dependence on fossil fuels and mitigate many of the concerns and limitations encountered in conventional axial bearings such as bearing wear, leaks, seals and friction loss. The Axial Halbach Magnetic Bearing is inherently stable and requires no active feedback control system or superconductivity as required in many magnetic bearing designs. The Axial Halbach Magnetic Bearing is useful for very high speed applications including turbines, instrumentation, medical systems, computer memory systems, and space power systems such as flywheels. Magnetic fields suspend and support a rotor assembly within a stator. Advanced technologies developed for particle accelerators, and currently under development for maglev trains and rocket launchers, served as the basis for this application. Experimental hardware was successfully designed and developed to validate the basic principles and analyses. The report concludes that the implementation of Axial Halbach Magnetic Bearings can provide significant improvements in rotational system performance and reliability.

  13. Development and Testing of a Radial Halbach Magnetic Bearing

    Science.gov (United States)

    Eichenberg, Dennis J.; Gallo, Christopher A.; Thompson, William K.

    2006-01-01

    The NASA John H. Glenn Research Center has developed and tested a revolutionary Radial Halbach Magnetic Bearing. The objective of this work is to develop a viable non-contact magnetic bearing utilizing Halbach arrays for all-electric flight, and many other applications. This concept will help reduce harmful emissions, reduce the Nation s dependence on fossil fuels and mitigate many of the concerns and limitations encountered in conventional axial bearings such as bearing wear, leaks, seals and friction loss. The Radial Halbach Magnetic Bearing is inherently stable and requires no active feedback control system or superconductivity as required in many magnetic bearing designs. The Radial Halbach Magnetic Bearing is useful for very high speed applications including turbines, instrumentation, medical applications, manufacturing equipment, and space power systems such as flywheels. Magnetic fields suspend and support a rotor assembly within a stator. Advanced technologies developed for particle accelerators, and currently under development for maglev trains and rocket launchers, served as the basis for this application. Experimental hardware was successfully designed and developed to validate the basic principles and analyses. The report concludes that the implementation of Radial Halbach Magnetic Bearings can provide significant improvements in rotational system performance and reliability.

  14. Status of high temperature superconductor development for accelerator magnets

    Science.gov (United States)

    Hirabayashi, H.

    1995-01-01

    High temperature superconductors are still under development for various applications. As far as conductors for magnets are concerned, the development has just been started. Small coils wound by silver sheathed Bi-2212 and Bi-2223 oxide conductors have been reported by a few authors. Essential properties of high T(sub c) superconductors like pinning force, coherent length, intergrain coupling, weak link, thermal property, AC loss and mechanical strength are still not sufficiently understandable. In this talk, a review is given with comparison between the present achievement and the final requirement for high T(sub c) superconductors, which could be particularly used in accelerator magnets. Discussions on how to develop high T(sub c) superconductors for accelerator magnets are included with key parameters of essential properties. A proposal of how to make a prototype accelerator magnet with high T(sub c) superconductors with prospect for future development is also given.

  15. The sorption induced glass transition in amorphous glassy polymers

    NARCIS (Netherlands)

    van der Vegt, N.F.A.; Wessling, Matthias; Strathmann, H.; Briels, Willem J.

    1999-01-01

    Sorption of CO2 in both the glassy and the rubbery state of an amorphous polyethylenelike polymer was investigated using molecular dynamics simulations. The temperature was chosen such that the system was in its glassy state at low solute concentrations and its rubbery state at large solute

  16. Recent development in bonded NdFeB magnets

    International Nuclear Information System (INIS)

    Ma, B.M.; Herchenroeder, J.W.; Smith, B.; Suda, M.; Brown, D.N.; Chen, Z.

    2002-01-01

    The magnetic properties of isotropic NdFeB powders used for bonded magnets are compared. The characteristics of two newly developed powders, namely MQP-13-9 and MQP-S-9-8 were compared with respect to existing powders. The advantages of spherical powders for injection molding were highlighted. Development targets for the 180 deg. C application and NdFeB nanocomposites were also discussed

  17. Magnetic fusion energy research and development

    International Nuclear Information System (INIS)

    1984-02-01

    This report on the Department of Energy's Magnetic Fusion Program was requested by the Secretary of Energy. The Panel finds that substantial progress has been made in the three years since the previous ERAB review, although budget constraints have precluded the engineering initiatives recommended in that review and authorized in the Magnetic Fusion Energy Engineering Act of 1980 (the Act). Recognizing that the goals of the Act cannot now be met, the Panel recommends that the engineering phase be further postponed in favor of a strong base program in physics and technology, including immediate commitment to a major new tokamak-based device for the investigation of an ignited long-pulse plasma designated in this report as the Burning Core Experiment or BCX. Resources to design such a device could be obtained from within the existing program by redirecting work toward to BCX. At this time it is not possible to assess accurately the potential economic viability of fusion power in the future. The Panel strongly recommends expansion of international collaboration, particularly the joint construction and operation of major new unique facilities, such as the proposed BCX

  18. Development of NdFeB magnet through hydrogen decrepitation

    International Nuclear Information System (INIS)

    Akhtar, S.; Farooque, M.; Haider, A.; Ahmad, Z.

    2009-01-01

    Neodymium based magnets are the powerful permanent magnet of today. This paper will discuss iron based rare earth magnets. NdFeB sintered magnet material has been developed. The magnets are produced by powder metallurgy route involving hydrogen decrepitation technique for making fine powder. After melting and casting, the NdFeB alloy is subject to hydrogen atmosphere. Hydrogen slowly absorbs into the solid alloy and makes it brittle, which upon milling becomes fine powder. Hydrogen is then removed by placing the powder at temperature around 800 deg. C under vacuum. Then the powders are pressed under isostatic conditions and sintered at temperature range of 1020-1050 deg. C. Post sintering is done at 800 deg. C and 580 deg. C followed by quenching. Energy product in the range of 8 MGOe is achieved. (author)

  19. Extended use of superconducting magnets for bio-medical development

    Energy Technology Data Exchange (ETDEWEB)

    Stoynev, Stoyan E. [Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States)

    2015-05-19

    Magnetic fields interact with biological cells affecting them in variety of ways which are usually hard to predict. Among them, it was observed that strong fields can align dividing cells in a preferred direction. It was also demonstrated that dividing cancer cells are effectively destroyed by applying electric fields in vivo with a success rate dependent on the cell-to-field orientation. Based on these facts, the present note aims to suggest the use of magnetic and electric fields for improved cancer treatment. Several possibilities of generating the electric fields inside the magnetic field volume are reviewed, main tentative approaches are described and discussed. Most if not all of them require special magnet configuration research which can be based on existing magnet systems in operation or in development.

  20. Voltammetric pH sensing using carbon electrodes: glassy carbon behaves similarly to EPPG.

    Science.gov (United States)

    Lu, Min; Compton, Richard G

    2014-09-21

    Developing and building on recent work based on a simple sensor for pH determination using unmodified edge plane pyrolytic graphite (EPPG) electrodes, we present a voltammetric method for pH determination using a bare unmodified glassy carbon (GC) electrode. By exploiting the pH sensitive nature of quinones present on carbon edge-plane like sites within the GC, we show how GC electrodes can be used to measure pH. The electro-reduction of surface quinone groups on the glassy carbon electrode was characterised using cyclic voltammetry (CV) and optimised with square-wave voltammetry (SWV) at 298 K and 310 K. At both temperatures, a linear correlation was observed, corresponding to a 2 electron, 2 proton Nernstian response over the aqueous pH range 1.0 to 13.1. As such, unmodified glassy carbon electrodes are seen to be pH dependent, and the Nernstian response suggests its facile use for pH sensing. Given the widespread use of glassy carbon electrodes in electroanalysis, the approach offers a method for the near-simultaneous measurement and monitoring of pH during such analyses.

  1. Development of a cryogenic permanent magnet undulator at the ESRF

    International Nuclear Information System (INIS)

    Kitegi, Ch.

    2008-12-01

    In 2004, at SPring-8, Toru Hara proposed a new concept of undulator with a short period and a high field: the Cryogenic Permanent Magnet Undulator (CPMU). The purpose of this concept is to cool Nd 2 Fe 14 B magnets at 150 K. This cooling allows magnets which have a higher remanence to be used, up to 40% higher than that of the magnets traditionally used in undulators. In order to assess the technological possibility of producing such undulator, a 2 m long undulator with a 18 mm period has been proposed at the ESRF. This piece of work presents the design and the construction of this CPMU at the ESRF. First a magnetic model of the CPMU is introduced; it is based on measurements of the magnetization curve at cryogenic temperature performed at the Louis Neel Laboratory. This model forecasts an increase of the peak field of 8% and of the field integral of 0.2 Gm at around 150 K. A unique magnetic measurement bench has been developed at the ESRF. This bench allows both the in vacuum local field and field integral to be measured. Its design and construction are presented. Finally we have reviewed the measurements at room and cryogenic temperature. These measurements are in agreement with the magnetic model. (author)

  2. Trends and developments in magnetic confinement fusion reactor concepts

    International Nuclear Information System (INIS)

    Baker, C.C.; Carlson, G.A.; Krakowski, R.A.

    1981-01-01

    An overview is presented of recent design trends and developments in reactor concepts for magnetic confinement fusion. The paper emphasizes the engineering and technology considerations of commercial fusion reactor concepts. Emphasis is placed on reactors that operate on the deuterium/tritium/lithium fuel cycle. Recent developments in tokamak, mirror, and Elmo Bumpy Torus reactor concepts are described, as well as a survey of recent developments on a wide variety of alternate magnetic fusion reactor concepts. The paper emphasizes recent developments of these concepts within the last two to three years

  3. Influence of 60-Hz magnetic fields on sea urchin development

    Energy Technology Data Exchange (ETDEWEB)

    Zimmerman, S.; Zimmerman, A.M.; Winters, W.D.; Cameron, I.L. (York Univ., Toronto, Ontario (Canada))

    1990-01-01

    Continuous exposure of sea urchin (Strongylocentrotus purpuratus) embryos at 18 degrees C to a cyclic 60-Hz magnetic field at 0.1 mT rms beginning 4 min after insemination caused a significant developmental delay during the subsequent 23 hours. No delay in development was recorded for periods up to 18 hours after fertilization. At 18 h, most embryos were in the mesenchyme blastula stage. At 23 h, most control embryos were in mid-gastrula whereas most magnetic-field-exposed embryos were in the early gastrula stage. Thus an estimated 1-h delay occurred between these developmental stages. The results are discussed in terms of possible magnetic-field modification of transcription as well as interference with cell migration during gastrulation. The present study extends and supports the growing body of information about potential effects of exposures to extremely-low-frequency (ELF) magnetic fields on developing organisms.

  4. The zero-field glassy ground state and field-induced ferromagnetic transition in (La{sub 0.4}Pr{sub 0.6}){sub 1.2}Sr{sub 1.8}Mn{sub 2}O{sub 7}

    Energy Technology Data Exchange (ETDEWEB)

    Tackett, R; Lawes, G; Suryanarayanan, R [Department of Physics and Astronomy, Wayne State University, Detroit, MI 48201 (United States); Apostu, M [Faculty of Chemistry, Physical, Theoretical and Materials Chemistry, Alexandru Cuza University, Iasi 700506 (Romania); Revcolevschi, A, E-mail: glawes@wayne.edu [Laboratoire de Physico-Chimie de l' Etat Solide, ICMMO, CNRS-UMR 8182, Universite Paris-Sud, 91405 Orsay (France)

    2011-04-20

    We have investigated glassy magnetic freezing in (La{sub 0.4}Pr{sub 0.6}){sub 1.2}Sr{sub 1.8}Mn{sub 2}O{sub 7} single crystals together with the field-induced transition to a metastable ferromagnetic phase using ac magnetic susceptibility and heat capacity measurements. The magnetization measurements show evidence for the development of a zero-field glassy ground state below 45 K along with a hysteretic, field-induced change in susceptibility associated with the transition to the ferromagnetic phase above 5 T. The heat capacity develops a clear peak at higher temperatures with the application of large magnetic fields, consistent with the development of a ferromagnetic order, while at low temperatures the Sommerfeld coefficient is monotonically reduced by an applied field, suggesting suppression of spin fluctuations. The heat capacity shows hysteretic behaviour, accompanied by a sharp decrease at a critical field, when held at fixed temperature, which does not recover on reducing the field back to zero. These measurements suggest that the zero-field ground state for (La{sub 0.4}Pr{sub 0.6}){sub 1.2}Sr{sub 1.8}Mn{sub 2}O{sub 7} consists of frozen disordered spin clusters, which develop into a metastable ferromagnetic state in modest magnetic fields.

  5. The Anisotropic Glassy Properties of Decagonal Quasicrystals

    Directory of Open Access Journals (Sweden)

    Dragoş-Victor Anghel

    2013-01-01

    Full Text Available We use an extended version of the standard tunneling model to explain the anisotropic sound absorption in decagonal quasicrystals. The glassy properties are determined by an ensemble of two level systems (TLSs, arbitrarily oriented. The TLS is characterized by a 3 × 3 symmetric tensor, [T], which couples to the strain field, [S], through a 3 × 3 × 3 × 3 tensor of coupling constants, [R]. The structure of [R] reflects the symmetry of the quasicrystal. We also analyze the probability distributions of the elements of [T] in this particular model for a better understanding of the characteristics of “isotropic” and “anisotropic” distributions of the ensemble of TLSs. We observe that the distribution of the elements is neither simple nor intuitive and therefore it is difficult to guess it a priory, using qualitative arguments based on the symmetry properties.

  6. MHD magnet technology development program summary, September 1982

    Energy Technology Data Exchange (ETDEWEB)

    1983-11-01

    The program of MHD magnet technology development conducted for the US Department of Energy by the Massachusetts Institute of Technology during the past five years is summarized. The general strategy is explained, the various parts of the program are described and the results are discussed. Subjects covered include component analysis, research and development aimed at improving the technology base, preparation of reference designs for commercial-scale magnets with associated design evaluations, manufacturability studies and cost estimations, the detail design and procurement of MHD test facility magnets involving transfer of technology to industry, investigations of accessory subsystem characteristics and magnet-flow-train interfacing considerations and the establishment of tentative recommendations for design standards, quality assurance procedures and safety procedures. A systematic approach (framework) developed to aid in the selection of the most suitable commercial-scale magnet designs is presented and the program status as of September 1982 is reported. Recommendations are made for future work needed to complete the design evaluation and selection process and to provide a sound technological base for the detail design and construction of commercial-scale MHD magnets. 85 references.

  7. MHD magnet technology development program summary, September 1982

    International Nuclear Information System (INIS)

    1983-11-01

    The program of MHD magnet technology development conducted for the US Department of Energy by the Massachusetts Institute of Technology during the past five years is summarized. The general strategy is explained, the various parts of the program are described and the results are discussed. Subjects covered include component analysis, research and development aimed at improving the technology base, preparation of reference designs for commercial-scale magnets with associated design evaluations, manufacturability studies and cost estimations, the detail design and procurement of MHD test facility magnets involving transfer of technology to industry, investigations of accessory subsystem characteristics and magnet-flow-train interfacing considerations and the establishment of tentative recommendations for design standards, quality assurance procedures and safety procedures. A systematic approach (framework) developed to aid in the selection of the most suitable commercial-scale magnet designs is presented and the program status as of September 1982 is reported. Recommendations are made for future work needed to complete the design evaluation and selection process and to provide a sound technological base for the detail design and construction of commercial-scale MHD magnets. 85 references

  8. Glassy Carbon Coating Deposited on Hybrid Structure of Composite Materials

    Directory of Open Access Journals (Sweden)

    Posmyk A.

    2016-06-01

    Full Text Available This paper presents a method of production metal matrix composites with aluminum oxide foam covered by glassy carbon layer used as reinforcement. The glassy carbon coating was formed for decreasing of friction coefficient and reducing the wear. In first step of technology liquid glassy carbon precursor is on ceramic foam deposited, subsequently cured and carbonated at elevated temperature. In this way ceramic foam is covered with glassy carbon coating with thickness of 2-8 μm. It provides desirable amount of glassy carbon in the structure of the material. In the next step, porous spheres with carbon coating are infiltrated by liquid matrix of Al-Cu-Mg alloy. Thereby, equable distribution of glassy carbon in composite volume is achieved. Moreover, typical problems for composites reinforced by particles like sedimentation, agglomeration and clustering of particles are avoided. Tribological characteristics during friction in air versus cast iron as a counterpart were made. Produced composites with glassy carbon layer are characterised by friction coefficient between 0.08-0.20, thus meeting the typical conditions for solid lubricants.

  9. New developments in NdFeB-based permanent magnets

    International Nuclear Information System (INIS)

    Liu, Z.W.

    2011-01-01

    NdFeB based alloys have been used as permanent magnets for almost thirty years. The recent researches aim at optimizing the composition, microstructure and properties, reducing cost, and developing new processes. The demand for sintered magnet is increasing. Efforts are directed towards improving properties by controlling grain boundary diffusion, minimizing the rare earth (RE) content and also improving production yield. As for bonded magnets, to enhance remanence and energy product, nanocrystalline powders are employed. High thermal stability has been realized by mixing NdFeB with hard ferrite powders. For nanocrystalline and nano composite NdFeB based alloys, both compositional modification and microstructural optimization have been carried out. New approaches have also been proposed to prepare NdFeB magnets with idea structure. Surfactant assisted ball milling is a good top-down method to obtain nano sized hard magnetic particles and anisotropic nano flakes. Synthesis of NdFeB nanoparticles and NdFeB/Fe (Co) nano composite powders by bottom-up techniques, such as chemical reduction process and co-precipitation, has been successful very recently. To assemble nanocrystalline NdFeB powders or nanoparticles into bulk magnets, various novel consolidation processes including spark plasma sintering and high velocity press have been employed. Hot deformation can be selected as the process to achieve anisotropy in nanocrystalline magnets. (author)

  10. Magnet and conductor developments for the Mirror Fusion Program

    International Nuclear Information System (INIS)

    Cornish, D.N.

    1981-01-01

    The conductor development and the magnet design and construction for the MFTF are described. Future plans for the Mirror Program and their influence on the associated superconductor development program are discussed. Included is a summary of the progress being made to develop large, high-field, multifilamentary Nb 3 Sn superconductors and the feasibility of building a 12-T yin-yang set of coils for the machine to follow MFTF. In a further look into the future, possible magnetic configurations and requirements for mirror reactors are surveyed

  11. Formation of a glassy phase in ceramic-like coatings

    International Nuclear Information System (INIS)

    Sazonova, M.V.; Gorbatova, G.N.

    1986-01-01

    The authors investigate the synthesis directly in coatings of a borosilicate melt that could fill the role of glassy matrix, thereby avoiding fusion and processing of the glassy material. The effect of added boron on the formation of coatings based on molybdenum disilicide and tungsten disilicide in air at 900 degrees C is presented. Without an additive no coating forms; there is no adhesion to the graphite and a continuous film does not form. As a result of boron oxidation an easily fused glassy matrix forms, which bonds the molybdenum disilicide or tungsten disilicide particles together and ensures adhesion to the graphite

  12. Atmospheric pressure plasma treatment of glassy carbon for adhesion improvement

    DEFF Research Database (Denmark)

    Kusano, Yukihiro; Mortensen, Henrik Junge; Stenum, Bjarne

    2007-01-01

    Glassy carbon plates were treated with an atmospheric pressure dielectric barrier discharge (DBD). He gas, gas mixtures of He and reactive gases such as O2, CO2 and NH3, Ar gas and Ar/NH3 gas mixture were used as treatment gases. The oxygen and nitrogen contents on the surface as well as defect...... density increased with the plasma treatments. Adhesion test of the treated glassy carbon covered with cured epoxy showed cohesive failure, indicating strong bonding after the treatments. This is in contrast to the adhesion tests of untreated samples where the epoxy readily peeled off the glassy carbon....

  13. Developing Antitumor Magnetic Hyperthermia: Principles, Materials and Devices.

    Science.gov (United States)

    Tishin, Alexander M; Shtil, Alexander A; Pyatakov, Alexander P; Zverev, Vladimir I

    2016-01-01

    Methods of local or loco-regional anticancer treatment are of the utmost importance because the therapeutic 'power' is applied directly to the disease site. Consequently, general toxicity is minimized. Hyperthermia, that is, a sustained increase of intratumoral temperature up to 45oC, has been investigated as a perspective treatment modality alone and/or in combination with ionizing radiation or chemotherapy. Still, the surrounding tissues can be damaged by the external heat. Development of new materials and devices gave rise to methods of inducing hyperthermia by a high frequency magnetic or electromagnetic field applied to the tumor with exogenous nanosized particles captured within it. The idea of this approach is the release of local heat in the vicinity of the magnetic nanoparticle in a time-varying magnetic field due to transfer of external magnetic field energy into the heat. Therefore, tumor cells are heated whereas the peritumoral non-malignant tissues are spared. This review analyzes recent advances in understanding physical principles that underlie magnetic hyperthermia as well as novel approaches to obtain nanoparticles with optimized physico-chemical, toxicological and tumoricidal properties. Special focus is made on the construction of devices for therapeutic purposes. The review covers recent patents and general literature sources regarding magnetic hyperthermia, the developing approach to treat otherwise intractable malignancies.

  14. Developments in materials for high-field magnets

    Energy Technology Data Exchange (ETDEWEB)

    Sims, J.R.; Hill, M.A. [Los Alamos National Lab., NM (United States); Walsh, R.P. [National Inst. of Standards and Technology (MSEL), Boulder, CO (United States). Materials Reliability Div.

    1993-10-01

    Results of the National High Magnetic Field Laboratory`s program of characterization of materials and fabrication techniques used in the construction of high-field pulsed magnets are reported. High-field pulsed magnets require conductors with high mechanical strength (750 MPa or greater YS at 77K) and high electrical conductivity (70% IACS or greater at RT). Electrical insulation and resin systems for vacuum impregnation with high compressive strength (500 MPa at 77K) and moderate thermal conductivity (1kW/mK at 77K) are also required. Developments and future plans for the characterization of new magnet material systems are discussed. Testing result are reported: Mechanical and fatigue testing, electrical conductivity testing and thermal expansion measurements of high strength, high conductivity conductors at cryogenic and room temperature, mechanical testing of a coil support material at cryogenic and room temperature, thermal expansion and thermal conductivity tests of an electrical insulating system at cryogenic temperatures.

  15. Progress in development of high capacity magnetic HTS bearings

    International Nuclear Information System (INIS)

    Kummeth, P.; Nick, W.; Neumueller, H.-W.

    2005-01-01

    HTS magnetic bearings are inherently stable without an active feedback system. They provide low frictional losses, no wear and allow operation at high rotational speed without lubrication. So they are very promising for use in motors, generators and turbines. We designed and constructed an HTS radial bearing for use with a 400 kW HTS motor. It consists of alternating axially magnetized permanent magnet rings on the rotor and a segmented YBCO stator. Stator cooling is performed by liquid nitrogen, the temperature of the stator can be adjusted by varying the pressure in the cryogenic vessel. At 68 K maximum radial forces of more than 3.7 kN were found. These results range within the highest radial bearing capacities reported worldwide. The encouraging results lead us to develop a large heavy load HTS radial bearing. Currently a high magnetic gradient HTS bearing for a 4 MVA synchronous HTS generator is under construction

  16. The development of magnetic resonance imaging in obstetrics.

    Science.gov (United States)

    Duncan, K R

    Following recent developments in imaging techniques which overcome the problem of fetal motion, magnetic resonance imaging (MRI) has the potential to improve non-invasive fetomaternal assessment. This article catalogues the development of MRI and the potential that exists for its use in obstetrics in the future.

  17. Development of Smart Optical Gels with Highly Magnetically Responsive Bicelles.

    Science.gov (United States)

    Isabettini, Stéphane; Stucki, Sandro; Massabni, Sarah; Baumgartner, Mirjam E; Reckey, Pernille Q; Kohlbrecher, Joachim; Ishikawa, Takashi; Windhab, Erich J; Fischer, Peter; Kuster, Simon

    2018-03-14

    Hydrogels delivering on-demand tailorable optical properties are formidable smart materials with promising perspectives in numerous fields, including the development of modern sensors and switches, the essential quality criterion being a defined and readily measured response to environmental changes. Lanthanide ion (Ln 3+ )-chelating bicelles are interesting building blocks for such materials because of their magnetic responsive nature. Imbedding these phospholipid-based nanodiscs in a magnetically aligned state in gelatin permits an orientation-dependent retardation of polarized light. The resulting tailorable anisotropy gives the gel a well-defined optical signature observed as a birefringence signal. These phenomena were only reported for a single bicelle-gelatin pair and required high magnetic field strengths of 8 T. Herein, we demonstrate the versatility and enhance the viability of this technology with a new generation of aminocholesterol (Chol-NH 2 )-doped bicelles imbedded in two different types of gelatin. The highly magnetically responsive nature of the bicelles allowed to gel the anisotropy at commercially viable magnetic field strengths between 1 and 3 T. Thermoreversible gels with a unique optical signature were generated by exposing the system to various temperature conditions and external magnetic field strengths. The resulting optical properties were a signature of the gel's environmental history, effectively acting as a sensor. Solutions containing the bicelles simultaneously aligning parallel and perpendicular to the magnetic field directions were obtained by mixing samples chelating Tm 3+ and Dy 3+ . These systems were successfully gelled, providing a material with two distinct temperature-dependent optical characteristics. The high degree of tunability in the magnetic response of the bicelles enables encryption of the gel's optical properties. The proposed gels are viable candidates for temperature tracking of sensitive goods and provide

  18. Development of partially-stabilized pulsed superconducting magnets

    International Nuclear Information System (INIS)

    Tateishi, Hiroshi; Onishi, Toshitada; Komuro, Kazuo; Koyama, Kenichi

    1987-01-01

    Two types of pulsed superconducting cables and four pulsed superconducting magnets have been developed in order to investigate basic problems in constructing ohmic heating coils of a tokamak-type fusion reactor. We found that a compacted cable is superior in mechanical rigidity and a braided cable is superior in cooling capacity as a conductor of a pulsed magnet. Stored energy and a maximum field of the magnets are 78 kJ and 6 T, 68 kJ and 4 T, 375 kJ and 6 T, and 363 kJ and 3 T, respectively. Some of these magnets quenched in pulsive operations due to excessive ac losses or macroscopic wire motions. Therefore, main conditions for operating pulsed magnets without quenching are (1) to make ac losses low enough to be cooled with liquid helium existing near at the conductor surface by reducing filament diameter to the order of 10 μm and utilizing CuNi as matrix effectively, and (2) to prevent macroscopic wire motions by partial solderfilling of a cable or winding a magnet with strong tension. (author)

  19. Developments at the High Field Magnet Laboratory in Nijmegen

    Science.gov (United States)

    Perenboom, J. A. A. J.; Maan, J. C.; van Breukelen, M. R.; Wiegers, S. A. J.; den Ouden, A.; Wulffers, C. A.; van der Zande, W. J.; Jongma, R. T.; van der Meer, A. F. G.; Redlich, B.

    2013-03-01

    The High Field Magnet Laboratory at the Radboud University Nijmegen is rapidly expanding its capabilities. The developments encompass both organizational changes and new possibilities for research. The organization of the HFML was strengthened as a consequence of stronger participation of the Foundation for Fundamental Research on Matter (FOM), and an increase of the core-funding. This change makes that HFML is now considered on a national level as large research facility that operates at an international scale. At the same time work is underway to build new and powerful magnets, and provide electromagnetic radiation for magneto-spectroscopic studies. Electromagnetic radiation in the infrared and far-infrared spectrum will soon be available in the HFML with wavelengths between 3 μm and 1.5 mm, produced by the `FELIX' facility, comprising the long-wavelength free electron laser `FLARE' that in September 2011 produced its first light and the free electron lasers that have been moved from Rijnhuizen to Nijmegen. In magnet technology great strides are made to make magnets available for the user community with unprecedented performance: late in 2012 we hope to commission a new all-resistive magnet system that will generate a steady magnetic field as high as 38 T, by fully exploiting the maximum power of the installation, i.e. 20 MW, and using all available improvements in the design and construction of `Florida-Bitter' resistive magnets. We are also well underway with the design of a 45 T hybrid magnet system, using Nb3Sn superconductors and wind-and-react Cable-in-Conduit technology.

  20. Surface characterization of silver and palladium modified glassy ...

    Indian Academy of Sciences (India)

    WINTEC

    formaldehyde resin. Three types of precursor resin samples were prepared: (i) phenol-formal- dehyde resin without any additions in order to obtain pure glassy carbon precursor before polymerization, (ii) phenol- formaldehyde resin mixed with boric ...

  1. Development of Prototype HTS Components for Magnetic Suspension Applications

    Science.gov (United States)

    Haldar, P.; Hoehn, J., Jr.; Selvamanickam, V.; Farrell, R. A.; Balachandran, U.; Iyer, A. N.; Peterson, E.; Salazar, K.

    1996-01-01

    We have concentrated on developing prototype lengths of bismuth and thallium based silver sheathed superconductors by the powder-in-tube approach to fabricate high temperature superconducting (HTS) components for magnetic suspension applications. Long lengths of mono and multi filament tapes are presently being fabricated with critical current densities useful for maglev and many other applications. We have recently demonstrated the prototype manufacture of lengths exceeding 1 km of Bi-2223 multi filament conductor. Long lengths of thallium based multi-filament conductor have also been fabricated with practical levels of critical current density and improved field dependence behavior. Test coils and magnets have been built from these lengths and characterized over a range of temperatures and background fields to determine their performance. Work is in progress to develop, fabricate and test HTS windings that will be suitable for magnetic suspension, levitation and other electric power related applications.

  2. Glassy behavior of the Nd sublattice induced by Fe doping in NdFexGa1-xO3

    International Nuclear Information System (INIS)

    Bartolome, F.; Parra-Borderias, M.; Blasco, J.; Bartolome, J.

    2007-01-01

    The evolution of the magnetic ordering of Nd with the Fe content in NdFe x Ga 1-x O 3 is studied by low-temperature specific-heat measurements for x= =0.2. Fe doping creates a distribution of internal fields on Nd, originating a Schottky contribution to the specific heat which is present for x>0. The power law followed by the low-temperature specific heat suggests a glassy behavior for x>=0.1

  3. Development of a metallic magnetic calorimeter for high resolution spectroscopy

    International Nuclear Information System (INIS)

    Linck, M.

    2007-01-01

    In this thesis the development of a metallic magnetic calorimeter for high resolution detection of single x-ray quanta is described. The detector consists of an X-ray absorber and a paramagnetic temperature sensor. The raise in temperature of the paramagnetic sensor due to the absorption of a single X-ray is measured by the change in magnetization of the sensor using a low-noise SQUID magnetometer. The thermodynamic properties of the detector can be described by a theoretical model based on a mean field approximation. This allows for an optimization of the detector design with respect to signal size. The maximal archivable energy resolution is limited by thermodynamic energy fluctuations between absorber, heat bath and thermometer. An interesting field of application for a metallic magnetic calorimeter is X-ray astronomy and the investigation of X-ray emitting objects. Through high-resolution X-ray spectroscopy it is possible to obtain information about physical processes of even far distant objects. The magnetic calorimeter that was developed in this thesis has a metallic absorber with a quantum efficiency of 98% at 6 keV. The energy resolution of the magnetic calorimeter is EFWHM=2.7 eV at 5.9 keV. The deviation of the detector response from a linear behavior of the detector is only 0.8% at 5.9 keV. (orig.)

  4. Glassy state of native collagen fibril?

    Science.gov (United States)

    Gevorkian, S. G.; Allahverdyan, A. E.; Gevorgyan, D. S.; Hu, C.-K.

    2011-07-01

    Our micromechanical experiments show that viscoelastic features of type-I collagen fibril at physiological temperatures display essential dependence on the frequency and speed of heating. For temperatures of 20-30 °C the internal friction has a sharp maximum for a frequency less than 2 kHz. Upon heating the internal friction displays a peak at a temperature Tsoft(v) that essentially depends on the speed of heating v: Tsoft≈70°C for v=1°C/min, and Tsoft≈25°C for v=0.1°C/min. At the same temperature Tsoft(v) Young's modulus passes through a minimum. All these effects are specific for the native state of the fibril and disappear after heat-denaturation. Taken together with the known facts that the fibril is axially ordered as quasicrystal, but disordered laterally, we interpret our findings as indications of a glassy state, where Tsoft is the softening transition.

  5. Glassy dynamics in randomly pinned particle systems

    Science.gov (United States)

    Phan, Anh; Schweizer, Kenneth

    We generalize the force-level, microscopic Elastically Collective Nonlinear Langevin Equation theory of activated relaxation in bulk hard sphere and thermal liquids to address the role of internal quenched disorder. So-called neutral confinement is considered where a subset of particles are randomly pinned and there is no change of equilibrium pair structure. As the pinned fraction grows, the cage scale dynamical constraints are intensified, resulting in the mobile particles becoming more localized, a larger glassy shear modulus, and an enhanced cage scale barrier. However, based on an approximate analysis of how quenched disorder modifies collective elastic field fluctuations, random pinning is predicted to effectively screen or localize the strain field associated with the longer range elastic component of the activation barrier, leading to an overall reduction of it with pinning fraction. The different response of the cage and elastic barriers to quenched disorder results in subtle predictions for how the alpha relaxation time varies with pinning fraction and system volume fraction. A semi-quantitative comparison with recent simulations of a pinned-mobile water model are consistent with the theory. Predictions are made for thermal molecular liquids.

  6. Development of Ferrite-Coated Soft Magnetic Composites: Correlation of Microstructure to Magnetic Properties

    Science.gov (United States)

    Sunday, Katie Jo

    milling and analyzed for magnetic core loss dependence on particle size, cure temperature, and microstructure of both coating and core powder. We present a significant increase in core loss related to eddy current loss from coating particles sintering and Fe grain growth. Lastly, a more resistive coating material, NiZnCu-ferrite, is applied for improved resistivity, which leads to lower eddy current loss and improved magnetic performance. By highlighting the importance of microstructure and composition on magnetic properties, a closer look at interfacial features and local microstrain are necessary and accomplished in this work. Future developments of ferrite-based SMC coatings are required to transform the use of electromagnetic devices in today's society.

  7. Development of high temperature superconductors for magnetic field applications

    International Nuclear Information System (INIS)

    Larbalestier, D.C.

    1991-01-01

    The key requirement for magnetic field applications of high temperature superconductor (HTS) materials is to have conductors with high transport critical current density available for magnet builders. After 3 or 4 years of being without any such object, conductor makers have had recent success in producing simple conductor prototypes. These have permitted the construction of simple HTS magnets having self fields exceeding 1 tesla at 4K. Thus the scientific feasibility of making powerful HTS magnets has been demonstrated. Attention to the technological aspects of making HTS conductors for magnets with strong flux pinning and reduced superconducting granularity is now sensible and attractive. However, extrinsic defects such as filament sausaging, cracking, misaligned grains and other perturbations to long range current flow must be controlled at a low level if the benefit of intrinsic improvements to the critical current density is to be maintained in the conductor form. Due to the great complexity of HTS materials, there is sometimes confusion as to whether a given sample has an intrinsically or extrinsically limited critical current density. Systematic microstructure variation experiments and resistive transition analysis are shown to be particularly helpful in this phase of conductor development

  8. Voltammetric behavior of sedative drug midazolam at glassy carbon electrode in solubilized systems

    Directory of Open Access Journals (Sweden)

    Rajeev Jain

    2012-04-01

    Full Text Available Redox behavior of midazolam was studied at a glassy carbon electrode in various buffer systems, supporting electrolytes and pH using differential pulse, square-wave and cyclic voltammetry. Based on its reduction behavior, a direct differential pulse voltammetric method has been developed and validated for the determination of midazolam in parenteral dosage. Three well-defined peaks were observed in 0.1% SLS, Britton–Robinson (BR buffer of pH 2.5. The effect of surfactants like sodium lauryl sulfate (SLS, cetyl trimethyl ammonium bromide (CTAB and Tween 20 was studied. Among these surfactants SLS showed significant enhancement in reduction peak. The cathodic peak currents were directly proportional to the concentration of midazolam with correlation coefficient of 0.99. Keywords: Midazolam, Voltammetry, Surfactant, Glassy carbon electrode, Parenteral dosage form

  9. Comparison of the enthalpy recovery and free volume of polyvinylpyrrolidone during anomalous glassy to rubbery transition.

    Science.gov (United States)

    Zelkó, Romána; Süvegh, Károly

    2004-03-01

    Previous studies confirmed that along with the structural changes of the amorphous binder, that of the polyvinylpyrrolidone, the tensile strength and consequently, the dissolution behaviour of its tablets changed significantly during the storage period. Structural formation during the glassy to rubbery transition of polyvinylpyrrolidone was followed by the changes in the free volume and enthalpy recovery values of the polymer. The results suggest that the apparent structure formation of water and polymer under glassy to rubbery transition is interrelated in a dynamic and complex manner which can be tracked by the combination of enthalpy recovery studies and positron lifetime measurements. Positron lifetime measurements more sensitively react to the structural rearrangements than enthalpy recovery, thus it can be recommended as a sensitive tool for stability tests during the formulation phase of drug development.

  10. Treatment of early glassy cell carcinoma of uterine cervix

    International Nuclear Information System (INIS)

    Kim, Ok Bae; Kim, Jin Hee; Choi, Tae Jin

    2006-01-01

    The purpose of this study was to investigate the clinical findings, treatment, and outcome of patients with glassy cell carcinoma of cervix. We reviewed all cases of glassy cell carcinoma of the uterine cervix confirmed and treated at the Dongsan Medical Center, Keimyung University, between January 1993 and December 2005. There were 7 cases with histopathologically confirmed gassy cell carcinoma. A tumor was diagnosed as glassy cell carcinoma if over 50% of the tumor cell type displayed glassy cell features. Six patients with stage IB had radical hysterectomy and bilateral pelvic node dissection, and 2 of them received adjuvant external pelvic irradiation with concurrent chemotherapy. Remaining one patient with stage IIA had curative concurrent chemoradiotherapy with external pelvic irradiation and brachytherapy. There were 7 patients diagnosed as glassy cell carcinoma among the 3,745 (0.2%) patients of carcinoma of uterine cervix. The mean age of 7 patients was 44 years with range of 35 to 53 years of age. The most frequent symptom was vaginal bleeding (86%). By the punch biopsy undertaken before treatment of 7 cases, 2 only cases could diagnose as glassy cell carcinoma of uterine cervix, but remaining of them confirmed by surgical pathological examination. The mean follow up duration was 73 months with range of 13 to 150 months. All 7 patients were alive without disease after treatment. Glassy cell carcinoma of the uterine cervix is a distinct clinicopathologic entity that demonstrates an aggressive biologic behavior. However for early-stage disease, we may have more favorable clinical outcome with radical surgery followed by chemoradiotherapy

  11. Development of moving alternating magnetic filter using permanent magnet for removal of radioactive corrosion product from nuclear power plant

    International Nuclear Information System (INIS)

    Song, M. C.; Kim, S. I.; Lee, K. J.

    2002-01-01

    Radioactive Corrosion Products (CRUD) which are generated by the neutron activation of general corrosion products at the nuclear power plant are the major source of occupational radiation exposure. Most of the CRUD has a characteristic of showing strong ferrimagnetisms. Along with the new development and production of permanent magnet (rare earth magnet) which generates much stronger magnetic field than the conventional magnet, new type of magnetic filter that can separate CRUD efficiently and eventually reduce radiation exposure of personnel at nuclear power plant is suggested. This separator consists of inner and outer magnet assemblies, coolant channel and container surrounding the outer magnet assembly. The rotational motion of the inner and outer permanent magnet assemblies surrounding the coolant channel by driving motor system produces moving alternating magnetic fields in the coolant channel. The CRUD can be separated from the coolant by the moving alternating magnetic field. This study describes the results of preliminary experiment performed with the different flow rates of coolant and rotation velocities of magnet assemblies. This new magnetic filter shows better performance results of filtering the magnetite at coolant (water). Flow rates, rotating velocities of magnet assemblies and particle sizes turn out to be very important design parameters

  12. Development of a $Nb_{3}$Sn quadrupole magnet model

    CERN Document Server

    Devred, Arnaud; Gourdin, C; Juster, F P; Peyrot, M; Rey, J M; Rifflet, J M; Streiff, J M; Védrine, P

    2001-01-01

    One possible application of Nb/sub 3/Sn, whose superconducting properties far exceed those of NbTi, is the fabrication of short and powerful quadrupole magnets for the crowded interaction regions of large particle accelerators. To learn about Nb/sub 3/Sn technology and to evaluate fabrication techniques, DAPNIA/STCM at CEA/Saclay has undertaken an R&D program aimed at designing and building a 1 m-long, 56 mm single-aperture quadrupole magnet model. The model relies on the same coil geometry as the LHC arc quadrupole magnets, but has no iron yoke. It is expected to produce a nominal field gradient of 211 T/m at 11870 A. The coils are wound from Rutherford-type cables insulated with quartz fiber tapes, before being heat-treated and vacuum-impregnated with epoxy resin. Laminated, austenitic collars, locked around the coil assembly by means of keys restrain the Lorentz forces. After reviewing the conceptual design of the magnet model, we report on the cable and cable insulation development programs and we pre...

  13. Development of an all-nitride magnetic tunnel junction

    NARCIS (Netherlands)

    Borsa, D.M.; Grachev, S.Y.; Kerssemakers, J.W J; Boerma, D.O

    We are developing an all-nitride magnetic tunnel junction. Here, we report on the growth and properties of gamma'-Fe4N, alpha"-Fe16N2 and Cu3N. Epitaxial gamma'-Fe4N films were grown by molecular beam epitaxy of iron in the presence of atomic nitrogen from an RF atomic source. Layers of Cu3N were

  14. Thermal Barrier Coatings Resistant to Glassy Deposits

    Science.gov (United States)

    Drexler, Julie Marie

    Engineering of alloys has for years allowed aircraft turbine engines to become more efficient and operate at higher temperatures. As advancements in these alloy systems have become more difficult, ceramic thermal barrier coatings (TBCs), often yttria (7 wt %) stabilized zirconia (7YSZ), have been utilized for thermal protection. TBCs have allowed for higher engine operating temperatures and better fuel efficiency but have also created new engineering problems. Specifically, silica based particles such as sand and volcanic ash that enter the engine during operation form glassy deposits on the TBCs. These deposits can cause the current industrial 7YSZ thermal barrier coatings to fail since the glass formed penetrates and chemically interacts with the TBC. When this occurs, coating failure may occur due to a loss of strain tolerance, which can lead to fracture, and phase changes of the TBC material. There have been several approaches used to stop calcium-magnesium aluminio-silcate (CMAS) glasses (molten sand) from destroying the entire TBC, but overall there is still limited knowledge. In this thesis, 7YSZ and new TBC materials will be examined for thermochemical and thermomechanical performance in the presence of molten CMAS and volcanic ash. Two air plasma sprayed TBCs will be shown to be resistant to volcanic ash and CMAS. The first type of coating is a modified 7YSZ coating with 20 mol% Al2O3 and 5 mol% TiO2 in solid solution (YSZ+20Al+5Ti). The second TBC is made of gadolinium zirconate. These novel TBCs impede CMAS and ash penetration by interacting with the molten CMAS or ash and drastically changing the chemistry. The chemically modified CMAS or ash will crystallize into an apatite or anorthite phase, blocking the CMAS or ash from further destroying the coating. A presented mechanism study will show these coatings are effective due to the large amount of solute (Gd, Al) in the zirconia structure, which is the key to creating the crystalline apatite or

  15. Geographic distribution and relative abundance of the invasive glassy-winged sharpshooter: effects of temperature and egg parasitoids.

    Science.gov (United States)

    Gutierrez, Andrew Paul; Ponti, Luigi; Hoddle, Mark; Almeida, Rodrigo P P; Irvin, Nicola A

    2011-08-01

    The capacity to predict the geographic distribution and relative abundance of invasive species is pivotal to developing policy for eradication or control and management. Commonly used methods fall under the ambit of ecological niche models (ENMs). These methods were reviewed and shortcomings identified. Weather-driven physiologically based demographic models (PBDMs) are proposed that resolve many of the deficiencies of ENMs. The PBDM approach is used to analyze the invasiveness of the polyphagous glassy-winged sharpshooter (Homalodisca vitripennis [Germar]), a pest native to the southeastern United States and northeastern Mexico that extended its range into California in 1989. Glassy-winged sharpshooter vectors the pathogenic bacterium, Xylella fastidiosa (Wells) that causes Pierce's disease in grape and scorch-like diseases in other plants. PBDMs for glassy-winged sharpshooter and its egg parasitoids (Gonatocerus ashmeadi Girault and G. triguttatus Girault) were developed and linked to a PBDM for grape published by Wermelinger et al. (1991). Daily weather data from 108 locations across California for the period 1995-2006 were used to drive the PBDM system, and GRASS GIS was used to map the simulation results. The geographic distribution of glassy-winged sharpshooter, as observed, is predicted to be largely restricted to the warm areas of southern California, with the action of the two egg parasitoids reducing its abundance >90%. The average indispensable mortality contributed by G. triguttatus is central valley of California. The utility of holistic analyses for formulating control policy and tactics for invasive species is discussed.

  16. Superconducting magnet development program progress report, July 1974--June 1975

    International Nuclear Information System (INIS)

    Cornish, D.N.; Harvey, A.R.; Nelson, R.L.; Taylor, C.E.; Zbasnik, J.P.

    1975-01-01

    During FY 1975, the superconducting magnet development program at the Lawrence Livermore Laboratory was primarily directed toward the development of multifilamentary Nb 3 Sn conductor for large CTR machines. It was secondarily concerned with preliminary work for the MX experiment and with the acquisition of additional testing facilities. Among the significant achievements was the construction and operation of a 27-cm-bore coil to its short-sample limit of 7-T at the windings. The coil was wound with a 100-m length of 67,507-filament Nb 3 Sn conductor

  17. The Development of Drift Wave Turbulence in Magnetic Reconnection

    Science.gov (United States)

    McMurtrie, L.; Drake, J. F.; Swisdak, M. M.

    2013-12-01

    An important feature in collisionless magnetic reconnection is the development of sharp discontinuities along the separatrices bounding the Alfvenic outflow. The typical scale length of these features is ρs (the Larmor radius based on the sound speed) for guide field reconnection. Temperature gradients in the inflowing plasma (as might be found in the magnetopause) can lead to instabilities at these separatrices, specifically drift wave turbulence. We present standalone 2D and 3D PIC simulations of drift wave turbulence to investigate scaling properties and growth rates. Further investigations of the relative importance of drift wave turbulence in the development of reconnection will also be considered.

  18. Dielectric Relaxation in Glassy Se100 - x Sbx

    OpenAIRE

    CHOUDHARY, N.; KUMAR, A.

    2014-01-01

    Frequency and temperature dependence of dielectric constant \\varepsilon' and dielectric loss \\varepsilon'' are studied in glassy Se1-x Sbx (x = 0, 0.02, 0.04, 0.06, 0.08 and 0.10) in the frequency range from 1--10 kHz and in the temperature range 290 K to 360 K. The experimental results indicate that no dielectric dispersion exist in glassy Se in the operating range of frequencies. However, when Sb concentration increases in Se1-x Sbx (x = 0.02, 0.04, 0.06, ...

  19. Development of Metallic Magnetic Calorimeters for Nuclear Safeguards Applications

    Energy Technology Data Exchange (ETDEWEB)

    Bates, Cameron Russell [Univ. of California, Berkeley, CA (United States)

    2015-03-11

    Many nuclear safeguards applications could benefit from high-resolution gamma-ray spectroscopy achievable with metallic magnetic calorimeters. This dissertation covers the development of a system for these applications based on gamma-ray detectors developed at the University of Heidelberg. It demonstrates new calorimeters of this type, which achieved an energy resolution of 45.5 eV full-width at half-maximum at 59.54 keV, roughly ten times better than current state of the art high purity germanium detectors. This is the best energy resolution achieved with a gamma-ray metallic magnetic calorimeter at this energy to date. In addition to demonstrating a new benchmark in energy resolution, an experimental system for measuring samples with metallic magnetic calorimeters was constructed at Lawrence Livermore National Laboratory. This system achieved an energy resolution of 91.3 eV full-width at half-maximum at 59.54 keV under optimal conditions. Using this system it was possible to characterize the linearity of the response, the count-rate limitations, and the energy resolution as a function of temperature of the new calorimeter. With this characterization it was determined that it would be feasible to measure 242Pu in a mixed isotope plutonium sample. A measurement of a mixed isotope plutonium sample was performed over the course of 12 days with a single two-pixel metallic magnetic calorimeter. The relative concentration of 242Pu in comparison to other plutonium isotopes was determined by direct measurement to less than half a percent accuracy. This is comparable with the accuracy of the best-case scenario using traditional indirect methods. The ability to directly measure the relative concentration of 242Pu in a sample could enable more accurate accounting and detection of indications of undeclared activities in nuclear safeguards, a better constraint on source material in forensic samples containing plutonium, and improvements in verification in a future plutonium

  20. Development of a dc motor with virtually zero powered magnetic bearing

    Science.gov (United States)

    1971-01-01

    The development of magnetic bearings for use in direct current electric motors is discussed. The characteristics of the magnets used in the construction of the bearings are described. A magnetic bearing using steel armoring on permanent magnets was selected for performance tests. The specifications of the motor are presented. The test equipment used in the evaluation is described.

  1. Development of biodegradable scaffolds based on magnetically guided assembly of magnetic sugar particles.

    Science.gov (United States)

    Hu, Chengzhi; Uchida, Tomoyuki; Tercero, Carlos; Ikeda, Seiichi; Ooe, Katsutoshi; Fukuda, Toshio; Arai, Fumihito; Negoro, Makoto; Kwon, Guiryong

    2012-05-31

    Biodegradable scaffolds with controlled pore layout and porosity have great significance in tissue engineering for cell penetration, tissue ingrowth, vascularization, and nutrient delivery. Porogen leaching has been commonly used to control pore size, pore structure and porosity in the scaffold. In this paper we focus on the use/development of two magnetically guided porogen assembly methods using magnetic sugar particles (MSPs) for scaffold fabrication. First, a patterning device is utilized to align MSPs following designed templates. Then a magnetic sheet film is fabricated by mixing poly(vinyl alcohol, PVA) and NdFeB powder for steering the MSPs. After poly(l-lactide-co-ɛ-caprolactone) (PLCL) casting and removal of the sugar template, a scaffold with spherical pores is obtained. The surface and the inner structure of the scaffolds are evaluated using light and electron micrographs showing their interconnection of pores, pore wall morphology and porosity. Single layer scaffolds with the size of 8mm in width and 10mm in length were constructed with controllable pore diameters in the ranges of 105-150 μm, 250-300 μm and 425-500 μm. Copyright © 2012 Elsevier B.V. All rights reserved.

  2. Formulation development and evaluation of metronidazole magnetic nanosuspension as a magnetic-targeted and polymeric-controlled drug delivery system

    International Nuclear Information System (INIS)

    Latha, Subbiah; Selvamani, Palanisamy; Kumar, Chelladurai Senthil; Sharavanan, Palaniappan; Suganya, Govindan; Beniwal, Vijender Singh; Rao, Poduri Rama

    2009-01-01

    A nanosuspension of magnetically tagged metronidazole was developed by the solvent displacement method coupled with ultrasonication and was evaluated for its physicochemical properties. The drug release from metronidazole magnetic nanosuspension at pH 1.2 and 7.0 shows maximum correlation coefficient for zero order and Higuchi model, respectively. The anthelmintic activity of the formulated metronidazole magnetic nanosuspension was evaluated on Indian earthworms (Pheretima poi). Metronidazole magnetic nanosuspension at a dose of 10 and 50 mg/ml shortened by 31% and 34%, respectively, the mean time to death of the earthworms when compared against a non-magnetic metronidazole suspension. Thus, the developed metronidazole magnetic nanosuspension showed potent, controlled and targeted drug action and might be a good therapeutic avenue in combating infectious GI disorders.

  3. A viable dipole magnet concept with REBCO CORC® wires and further development needs for high-field magnet applications

    Science.gov (United States)

    Wang, Xiaorong; Caspi, Shlomo; Dietderich, Daniel R.; Ghiorso, William B.; Gourlay, Stephen A.; Higley, Hugh C.; Lin, Andy; Prestemon, Soren O.; van der Laan, Danko; Weiss, Jeremy D.

    2018-04-01

    REBCO coated conductors maintain a high engineering current density above 16 T at 4.2 K. That fact will significantly impact markets of various magnet applications including high-field magnets for high-energy physics and fusion reactors. One of the main challenges for the high-field accelerator magnet is the use of multi-tape REBCO cables with high engineering current density in magnet development. Several approaches developing high-field accelerator magnets using REBCO cables are demonstrated. In this paper, we introduce an alternative concept based on the canted cos θ (CCT) magnet design using conductor on round core (CORC®) wires that are wound from multiple REBCO tapes with a Cu core. We report the development and test of double-layer three-turn CCT dipole magnets using CORC® wires at 77 and 4.2 K. The scalability of the CCT design allowed us to effectively develop and demonstrate important magnet technology features such as coil design, winding, joints and testing with minimum conductor lengths. The test results showed that the CCT dipole magnet using CORC® wires was a viable option in developing a REBCO accelerator magnet. One of the critical development needs is to increase the engineering current density of the 3.7 mm diameter CORC® wire to 540 A mm-2 at 21 T, 4.2 K and to reduce the bending radius to 15 mm. This would enable a compact REBCO dipole insert magnet to generate a 5 T field in a background field of 16 T at 4.2 K.

  4. Developments in the field of active magnetic bearings at EDF

    International Nuclear Information System (INIS)

    Fanton, J.P.

    1993-10-01

    The studies carried out by EDF concerning the evaluation of the active magnetic bearing technology for their possible application to rotating machinery in electrical plants, and especially the 900 MW ''CP2'' turbogenerators which appear to have very little damping and vibrate noticeably during transients. Using a 4 tons test bench, the good quality of simulation applied to both permanent and transient conditions have been verified. Then, using a 10 tons test bench, the dimensioning concerns of the CP2 application were more precisely evaluated. It has been especially demonstrated that the accessible levels of force and damping were compatible with the application constraints. In a final 30 tons project, some innovative technological components have been used and the benefits from an optimization of the design of the magnetic parameters were determined. Specifications for a full-scale implementation have been therefore defined to enable the manufacturer to make a commercial offer. After a disappointing analysis of the offer, CP2 computations and studies were stopped but subsidiary studies were conducted: estimation of the damage risk under alternative bending of the CP2 rotors during their lifetime, prospective analysis of other possible applications of active magnetic bearings in power plants, development of a new vibratory test method through electromagnetic excitation. 5 figs., 6 refs

  5. Magnetic and inertial fusion status and development plans

    International Nuclear Information System (INIS)

    Correll, D.; Storm, E.

    1987-01-01

    Controlled fusion, pursued by investigators in both the magnetic and inertial confinement research programs, continues to be a strong candidate as an intrinsically safe and virtually inexhaustible long-term energy source. We describe the status of magnetic and inertial confinement fusion in terms of the accomplishments made by the research programs for each concept. The improvement in plasma parameters (most frequently discussed in terms of the Tn tau product of ion temperature, T, density, n, and confinement time, tau) can be linked with the construction and operation of experimental facilities. The scientific progress exhibited by larger scale fusion experiments within the US, such as Princeton Plasma Physics Laboratory's Fusion Test Reactor for magnetic studies and Lawrence Livermore National Laboratory's Nova laser for inertial studies, has been optimized by the theoretical advances in plasma and computational physics. Both TFTR and Nova have exhibited ion temperatures in excess of 10 keV at confinement parameters of n tau near 10 13 cm -3 . sec. At slightly lower temperatures (near a few keV), the value of n tau has exceeded 10 14 cm -3 . sec in both devices. Near-term development plans in fusion research include experiments within the US, Europe, and Japan to improve the plasma performance to reach conditions where the rate of fusion energy production equals or exceeds the heating power incident upon the plasma. 9 refs., 7 figs

  6. Magnetic particle imaging: current developments and future directions

    Directory of Open Access Journals (Sweden)

    Panagiotopoulos N

    2015-04-01

    Full Text Available Nikolaos Panagiotopoulos,1 Robert L Duschka,1 Mandy Ahlborg,2 Gael Bringout,2 Christina Debbeler,2 Matthias Graeser,2 Christian Kaethner,2 Kerstin Lüdtke-Buzug,2 Hanne Medimagh,2 Jan Stelzner,2 Thorsten M Buzug,2 Jörg Barkhausen,1 Florian M Vogt,1 Julian Haegele1 1Clinic for Radiology and Nuclear Medicine, University Hospital Schleswig Holstein, Campus Lübeck, 2Institute of Medical Engineering, University of Lübeck, Lübeck, Germany Abstract: Magnetic particle imaging (MPI is a novel imaging method that was first proposed by Gleich and Weizenecker in 2005. Applying static and dynamic magnetic fields, MPI exploits the unique characteristics of superparamagnetic iron oxide nanoparticles (SPIONs. The SPIONs’ response allows a three-dimensional visualization of their distribution in space with a superb contrast, a very high temporal and good spatial resolution. Essentially, it is the SPIONs’ superparamagnetic characteristics, the fact that they are magnetically saturable, and the harmonic composition of the SPIONs’ response that make MPI possible at all. As SPIONs are the essential element of MPI, the development of customized nanoparticles is pursued with the greatest effort by many groups. Their objective is the creation of a SPION or a conglomerate of particles that will feature a much higher MPI performance than nanoparticles currently available commercially. A particle’s MPI performance and suitability is characterized by parameters such as the strength of its MPI signal, its biocompatibility, or its pharmacokinetics. Some of the most important adjuster bolts to tune them are the particles’ iron core and hydrodynamic diameter, their anisotropy, the composition of the particles’ suspension, and their coating. As a three-dimensional, real-time imaging modality that is free of ionizing radiation, MPI appears ideally suited for applications such as vascular imaging and interventions as well as cellular and targeted imaging. A number

  7. Superconducting Cable Development for Future High Energy Physics Detector Magnets

    Science.gov (United States)

    Horvath, I. L.

    1995-11-01

    Under the leadership of the Swiss Federal Institute of Technology (ETHZ) an international ad hoc collaboration for superconducting cables developed an aluminium stabilised superconducting cable for future detector magnets. With the financial support of the Swiss government, this R&D work was carried out for the European Organisation for Nuclear Research (CERN). In this report the manufacturing process is described and results of the quality control measurements are summarised. These tests showed that the industrial manufacturing of an aluminium stabilised superconducting cable is feasible.

  8. Superconducting magnet development. Program annual report, July 1975--September 1976

    International Nuclear Information System (INIS)

    Deis, D.W.; Cornish, D.N.; Zbasnik, J.P.; Nelson, R.L.; Sackett, S.J.; Taylor, C.E.

    1977-01-01

    During FY76 Lawrence Livermore Laboratory (LLL) continued its development of niobium tin (Nb 3 Sn) conductors and its design support for the mirror fusion test facility (MFTF) superconducting magnet. Three highlights came from within the Laboratory. LLL completed its cryogenic tensile-test apparatus for NB 3 Sn strain measurements. Over at MFTF, engineers ordered 2100 m of prototype material for a 1-m test coil. People at the high-field test facility (HFTF) released some components for fabrication; delivery was scheduled for early FY77. Outside LLL several subcontractors advanced Nb 3 Sn manufacturing technology. One advance, in particular, improved conductor current densities at 12 T

  9. Recent development of micro-triangulation for magnet fiducialisation

    CERN Document Server

    Vlachakis, Vasileios; Mainaud Durand, Helene; CERN. Geneva. ATS Department

    2016-01-01

    The micro-triangulation method is proposed as an alternative for magnet fiducialisation. The main objective is to measure horizontal and vertical angles to fiducial points and stretched wires, utilising theodolites equipped with cameras. This study aims to develop various methods, algorithms and software tools to enable the data acquisition and processing. In this paper, we present the first test measurement as an attempt to demonstrate the feasibility of the method and to evaluate the accuracy. The preliminary results are very promising, with accuracy always better than 20 μm for the wire position, and of about40 μm/m for the wire orientation, compared with a coordinate measuring machine.

  10. Magnetic Resonance Imaging of Alimentary Tract Development in Manduca sexta.

    Directory of Open Access Journals (Sweden)

    Ian J Rowland

    Full Text Available Non-invasive 3D magnetic resonance imaging techniques were used to investigate metamorphosis of the alimentary tract of Manduca sexta from the larval to the adult stage. The larval midgut contracts in volume immediately following cessation of feeding and then greatly enlarges during the late pharate pupal period. Magnetic resonance imaging revealed that the foregut and hindgut of the pharate pupa undergo ecdysis considerably earlier than the external exoskeleton. Expansion of air sacs in the early pupa and development of flight muscles several days later appear to orient the midgut into its adult position in the abdomen. The crop, an adult auxiliary storage organ, begins development as a dorsal outgrowth of the foregut. This coincides with a reported increase in pupal ecdysteroid titers. An outgrowth of the hindgut, the rectal sac, appears several days later and continues to expand until it nearly fills the dorsal half of the abdominal cavity. This development correlates with a second rise in pupal ecdysteroid titers. In the pharate pupa, the presence of paramagnetic species renders the silk glands hyperintense.

  11. Emergence of Griffiths phase and glassy mixed phase in Sm0.5Ca0.5MnO3 nanomanganites

    International Nuclear Information System (INIS)

    Giri, S.K.; Yusuf, S.M.; Mukadam, M.D.; Nath, T.K.

    2014-01-01

    Graphical abstract: A detailed investigation on the effect of grain size on formation of Griffiths phase, and glassy mixed phase in CE-type antiferromagnetic Sm 0.5 Ca 0.5 MnO 3 manganite are carried out. A rigorous measurement of linear and non-linear ac magnetic susceptibilities, time dependent relaxation and aging phenomena in Sm 0.5 Ca 0.5 MnO 3 nanomanganite confirm the existence of a glassy mixed phase in the low temperature regime. The signature of Griffiths phase in nanosized manganite has been confirmed from the detailed ac and dc magnetization studies. The existence of Griffiths phase is verified through the anomalous behavior of the low field temperature dependent an inverse ac and dc magnetic susceptibility. Based on experimental results, the glassy phase of nanomanganites has been attributed to the phase separation effect and interaction between the ferromagnetic clusters. A phenomenological core/shell model has also been proposed based on the surface disorder to explain the observed Griffiths phase in these nanosized manganites. Fig. 1: (Left) The plot of inverse of ac susceptibility χ ac -1 measured at f = 1 Hz and H ac = 2 Oe as a function of temperature for S750 sample. Inset shows the same for S550 sample. (Right) A schematic of the proposed model to describe the magnetic state of the Sm 0.5 Ca 0.5 MnO 3 system at different average sizes. Highlights: • Effect of grain size on Griffiths phase and glassy mixed phase is discussed. • GP is confirmed by dc, linear and non-linear ac magnetization in nanomanganites. • Glassy mixed phase is discussed by time dependent relaxation and aging phenomena. • The existence of GP is verified through an inverse ac and dc magnetic susceptibility. • A phenomenological core/shell model has been proposed based on surface disorder. -- Abstract: A detailed investigation on the effect of grain size on formation of Griffiths phase (GP), and glassy mixed phase in CE-type antiferromagnetic Sm 0.5 Ca 0.5 MnO 3

  12. Relook on fitting of viscosity with undercooling of glassy liquids

    Indian Academy of Sciences (India)

    The method so far used is to get experimental visco- sity data of a liquid alloy at various temperatures and then fit a curve according to (1) to achieve values of the three VFT parameters (η0, D and T0). Glassy alloys enable to deter- mine viscosity of liquid in the temperature range between Tl and Tg because of its inherent ...

  13. Broadband nanoindentation of glassy polymers: Part II. Viscoplasticity

    Science.gov (United States)

    Joseph E. Jakes; Rod S. Lakes; Don S. Stone

    2012-01-01

    The relationship between hardness and flow stress in glassy polymers is examined. Materials studied include poly(methylmethacrylate), polystyrene, and polycarbonate. Properties are strongly rate dependent, so broadband nanoindentation creep (BNC) is used to measure hardness across a broad range of indentation strain rates (10-4 to 10 s

  14. Study of lithium glassy solid electrolyte/electrode interface by ...

    Indian Academy of Sciences (India)

    Cells of lithium ion conducting glassy electrolyte Li2SO4–Li2O–B2O3 with different combinations of electrodes (stainless steel blocking electrode, lithium non-blocking electrode and TiS2 electrode) have been prepared. The a.c. impedance measurements of the cells have been studied at elevated temperature as a function ...

  15. A study of nanostructured gold modified glassy carbon electrode for ...

    Indian Academy of Sciences (India)

    Wintec

    A study of nanostructured gold modified glassy carbon electrode for the determination of trace Cr(VI). BENZHI ... The method was applied to determine levels of chromium(VI) in tap water and sewage water. Keywords. Nanostructured gold modified ... analytical reagent-grade and double distilled water was used throughout.

  16. Aryl Diazonium Chemistry for the Surface Functionalization of Glassy Biosensors

    Directory of Open Access Journals (Sweden)

    Wei Zheng

    2016-03-01

    Full Text Available Nanostring resonator and fiber-optics-based biosensors are of interest as they offer high sensitivity, real-time measurements and the ability to integrate with electronics. However, these devices are somewhat impaired by issues related to surface modification. Both nanostring resonators and photonic sensors employ glassy materials, which are incompatible with electrochemistry. A surface chemistry approach providing strong and stable adhesion to glassy surfaces is thus required. In this work, a diazonium salt induced aryl film grafting process is employed to modify a novel SiCN glassy material. Sandwich rabbit IgG binding assays are performed on the diazonium treated SiCN surfaces. Fluorescently labelled anti-rabbit IgG and anti-rabbit IgG conjugated gold nanoparticles were used as markers to demonstrate the absorption of anti-rabbit IgG and therefore verify the successful grafting of the aryl film. The results of the experiments support the effectiveness of diazonium chemistry for the surface functionalization of SiCN surfaces. This method is applicable to other types of glassy materials and potentially can be expanded to various nanomechanical and optical biosensors.

  17. Aryl Diazonium Chemistry for the Surface Functionalization of Glassy Biosensors

    Science.gov (United States)

    Zheng, Wei; van den Hurk, Remko; Cao, Yong; Du, Rongbing; Sun, Xuejun; Wang, Yiyu; McDermott, Mark T.; Evoy, Stephane

    2016-01-01

    Nanostring resonator and fiber-optics-based biosensors are of interest as they offer high sensitivity, real-time measurements and the ability to integrate with electronics. However, these devices are somewhat impaired by issues related to surface modification. Both nanostring resonators and photonic sensors employ glassy materials, which are incompatible with electrochemistry. A surface chemistry approach providing strong and stable adhesion to glassy surfaces is thus required. In this work, a diazonium salt induced aryl film grafting process is employed to modify a novel SiCN glassy material. Sandwich rabbit IgG binding assays are performed on the diazonium treated SiCN surfaces. Fluorescently labelled anti-rabbit IgG and anti-rabbit IgG conjugated gold nanoparticles were used as markers to demonstrate the absorption of anti-rabbit IgG and therefore verify the successful grafting of the aryl film. The results of the experiments support the effectiveness of diazonium chemistry for the surface functionalization of SiCN surfaces. This method is applicable to other types of glassy materials and potentially can be expanded to various nanomechanical and optical biosensors. PMID:26985910

  18. Electrochemical behaviour of platinum at polymer-modified glassy ...

    Indian Academy of Sciences (India)

    TECS

    Abstract. In this paper, the preparations and voltammetric characteristics of chitosan-modified glassy carbon (Ct-MGC) and platinum electrodes are studied. Ct-MGC can be used for pre-concentration and quantification of trace amounts of platinum in solution. At low pH medium, the complex of Pt with pro- tonated group –NH.

  19. Electrochemical behaviour of platinum at polymer-modified glassy ...

    Indian Academy of Sciences (India)

    modified glassy carbon (Ct-MGC) and platinum electrodes are studied. Ct-MGC can be used for pre-concentration and quantification of trace amounts of platinum in solution. At low pH medium, the complex of Pt with protonated group -NH3+ in the ...

  20. Glassy carbon supercapacitor: 100,000 cycles demonstrated

    Energy Technology Data Exchange (ETDEWEB)

    Baertsch, M.; Braun, A.; Schnyder, B.; Koetz, R. [Paul Scherrer Inst. (PSI), Villigen (Switzerland)

    1999-08-01

    A 5 V glassy carbon capacitor stack was built consisting of four bipolar and two end-plate electrodes. More than 100,000 charging/discharging cycles were applied to test the stability of the double-layer capacitor. Low and high frequency resistances were measured as a function of the number of cycles. (author) 2 figs., 1 ref.

  1. Small angle neutron scattering from glassy SiO2

    International Nuclear Information System (INIS)

    Spooner, S.; Hastings, J.B.

    1976-01-01

    The present investigation of neutron scattering from glassy silica was undertaken to resolve whether the small angle scattering observed by Renninger and Uhlmann could also be seen in the bulk samples typically used in neutron-scattering experiments. Within the rather large error bars of this experiment no small angle scattering increase at small angles could be seen. (Auth.)

  2. Microscopic model of the glass transition and the glassy state

    International Nuclear Information System (INIS)

    Shukla, P.

    1982-07-01

    A microscopic model of the glass transition and the glassy state is presented. It is exactly solvable, and offers a unified view of the equilibrium and non-equilibrium aspects of the glass transition. It also provides a statistical-mechanical justification of the irreversible thermodynamic models of the glass transition proposed earlier. (author)

  3. Surface characterization of silver and palladium modified glassy ...

    Indian Academy of Sciences (India)

    WINTEC

    Abstract. In this work, the influence of silver and palladium on the surface of undoped, boron doped and phosphorus doped glassy carbon has been studied. The silver and palladium concentrations in solution, after metal deposition, were measured by atomic absorption spectrophotometer. The morphology of metal coatings.

  4. Aryl Diazonium Chemistry for the Surface Functionalization of Glassy Biosensors.

    Science.gov (United States)

    Zheng, Wei; van den Hurk, Remko; Cao, Yong; Du, Rongbing; Sun, Xuejun; Wang, Yiyu; McDermott, Mark T; Evoy, Stephane

    2016-03-14

    Nanostring resonator and fiber-optics-based biosensors are of interest as they offer high sensitivity, real-time measurements and the ability to integrate with electronics. However, these devices are somewhat impaired by issues related to surface modification. Both nanostring resonators and photonic sensors employ glassy materials, which are incompatible with electrochemistry. A surface chemistry approach providing strong and stable adhesion to glassy surfaces is thus required. In this work, a diazonium salt induced aryl film grafting process is employed to modify a novel SiCN glassy material. Sandwich rabbit IgG binding assays are performed on the diazonium treated SiCN surfaces. Fluorescently labelled anti-rabbit IgG and anti-rabbit IgG conjugated gold nanoparticles were used as markers to demonstrate the absorption of anti-rabbit IgG and therefore verify the successful grafting of the aryl film. The results of the experiments support the effectiveness of diazonium chemistry for the surface functionalization of SiCN surfaces. This method is applicable to other types of glassy materials and potentially can be expanded to various nanomechanical and optical biosensors.

  5. Playback interference of glassy-winged sharp shooter communication

    Science.gov (United States)

    Animal communication is vital to reproduction, particularly for securing a mate. Insects commonly communicate by exchanging vibrational signals that are transmitted through host plants. The glassy-winged sharpshooter (GWSS), Homalodisca vitripennis, is an important vector of Xylella fastidiosa, a pl...

  6. A study of nanostructured gold modified glassy carbon electrode for ...

    Indian Academy of Sciences (India)

    A nanostructured gold modified glassy carbon electrode (Aunano/GCE) was employed for the determination of trace chromium(VI). To prepare Aunano/GCE, the GCE was immersed into KAuCl4 solution and electrodeposition was conducted at the potential of -0.4 V (vs Ag/AgCl) for 600 s. Scanning electron microscopy ...

  7. Electrochemical oxidation of niclosamide at a glassy carbon ...

    African Journals Online (AJOL)

    Cyclic voltammetry, square-wave voltammetry and controlled potential electrolysis have been used to study the electrochemical oxidation behaviour of niclosamide at a glassy carbon electrode. The number of electrons transferred, the wave characteristics, the diffusion coefficient and reversibility of the reactions have been ...

  8. Disconnecting structure and dynamics in glassy thin films

    Science.gov (United States)

    Sussman, Daniel; Schoenholz, Samuel; Cubuk, Ekin; Liu, Andrea

    The dynamics near the surface of a glassy film are markedly different from those in the bulk. We investigate whether the differences between surface and bulk dynamics can be explained by differences in local microscopic structure. We show that machine learning methods that successfully identify strong correlations between local structure and particle rearrangement dynamics in the bulk completely fail to detect key aspects of thin-film glassy dynamics. Furthermore, we show that no combination of local structural features drawn from a very general set of two- and multi-point functions is able to distinguish between particles at the center of film and those in near the surface where the dynamics are strongly perturbed. We note that the behavior of glassy films has often been interpreted via a model with a glassy, immobile layer near the center of the film and liquid-like mobile layers near free interfaces. Our results suggest that the two populations are indistinguishable in structure, necessitating a purely dynamical theory for additional relaxation processes in the film.

  9. Development of nuclear magnetic resonance tomography technology - TORM

    International Nuclear Information System (INIS)

    Tannus, A.

    1987-01-01

    The development of hardware and software necessary to implement the Magnetic Resonance Imaging (MRI) techniques is described. The major subjects were the construction of an aquisition and control system which allowed the operation of a pulsed Fourier NMR spectrometer as a NMR Tomograph; further it was oriented the developing of a NMR spectrometer whose parameters could be easily reconfigured by the controlling system. As a result a sofisticated equipment which allows, more than the proposed, working with high resolution spectroscopic techniques and spectroscopy in solids, was obtained. Since the basic techniques employed in NMR and CT Tomographs are well known, a great emphasis was also given on the understanding of the image reconstruction techniques that constitutes today the frontier of research in this area. The results obtained with the system described here are considered good, comparable to the results from commercial units developed in cooperation with imaging groups located in universities abroad. (author) [pt

  10. FTIR and Mössbauer spectroscopic study of sodium-aluminum-iron phosphate glassy materials for high level waste immobilization

    Science.gov (United States)

    Stefanovsky, S. V.; Stefanovsky, O. I.; Remizov, M. B.; Belanova, E. A.; Kozlov, P. V.; Glazkova, Ya. S.; Sobolev, A. V.; Presniakov, I. A.; Kalmykov, S. N.; Myasoedov, B. F.

    2015-11-01

    Complex sodium-aluminum-iron phosphate glassy materials with various Al2O3 to Fe2O3 ratio containing high level waste (HLW) surrogate were characterized by X-ray diffraction and scanning electron microscopy and studied in details by Fourier transform infrared (FTIR) spectroscopy. The samples with high Al2O3 content and not containing Fe2O3 were predominantly amorphous but subjected to devitrification under annealing. Addition of B2O3 and partial Fe2O3 substitution for Al2O3 in the materials increases their resistance to devitrification whereas further substitution and NiO incorporation significantly increase the tendency to devitrification. FTIR spectra demonstrate changes in the structure of glassy materials caused by both structural variations in the anionic motif and occurrence of crystalline phases in the materials. According to Mössbauer spectroscopy data, iron in the glassy samples is present as octahedrally coordinated Fe3+ ions while in the partly devitrified samples iron is partitioned among vitreous and crystalline phases entering the vitreous phase mainly as Fe3+O6 units and crystalline phases as major Fe3+ and minor Fe2+ ions in a magnetically ordered state and participating in a "fast" electronic exchange.

  11. Development of magnets for infra-red-free electron laser project at RRCAT

    International Nuclear Information System (INIS)

    Ruwali, Kailash; Thakur, Vanshree; Das, S.; Biswas, Bhaskar; Singh, Kushraj; Amalraj, William; Sreeramulu, K.; Mishra, Anil Kumar; Shinde, R.S.

    2015-01-01

    This paper describes the design and development of the magnets for the beam transport line of Infra- red- Free Electron Laser (IR-FEL) project at RRCAT. All the magnets have been developed and fiducialized after magnetic characterization for installation in the tunnel. These magnets include three dipole magnets, twelve quadrupole magnets and twenty two steering magnets for bending, focussing and steering of 15 to 35 MeV electron beam through a dog-leg type beam line. The dipole magnet is designed as H type for a maximum magnetic field of 0.25 tesla with pole gap and bending angle of 42 mm and 22.5° respectively. The dipole magnet is quite thin (effective length ∼200 mm) therefore entry-exit ends were chamfered to achieve the integrated field uniformity of < 1 x 10 -3 within the good field zone. The quadrupole magnet is designed for maximum integrated strength of 2.5 T/m. The poles are wider than the coil to enhance the good field region and made detachable type. The pole profile is chosen as pure hyperbola with extension. Quadrupole magnets with two different sizes of apertures (aperture diameters of 60 mm and 40 mm) were developed. The steering magnet is designed for kick strength of 12 mrad at 25 MeV. Out of 22 steering magnets, 8 are vertical steering, 6 are horizontal steering and 8 combined function steering magnets. Magnetic measurements of dipole magnets were carried out in 3 axes Hall probe bench. Quadrupole and steering magnets were characterized in a rotating coil based harmonic measurement bench. The details of the design and magnetic measurements of these magnets with results will be discussed in this paper. (author)

  12. Magnets

    International Nuclear Information System (INIS)

    Young, I.R.

    1984-01-01

    A magnet pole piece for an NMR imaging magnet is made of a plurality of magnetic wires with one end of each wire held in a non-magnetic spacer, the other ends of the wires being brought to a pinch, and connected to a magnetic core. The wires may be embedded in a synthetic resin and the magnetisation and uniformity thereof can be varied by adjusting the density of the wires at the spacer which forms the pole piece. (author)

  13. Development of a magnetic measurement device for thin ribbon samples

    International Nuclear Information System (INIS)

    Sato, Yuta; Todaka, Takashi; Enokizono, Masato

    2008-01-01

    This paper presents a magnetic measurement device for thin ribbon samples, which are produced by rapid cooling technique. This device enables us to measure magnetic properties easily by only inserting a ribbon sample into a sample holder. The sample holder was made by bakelite to fix any width sample. A long solenoid coil was used to generate a uniform magnetic field and the sample holder was placed at the mid part of the solenoid. The magnetic field strength was measured using a shunt resistor and the magnetic flux density and magnetization in sample ribbons were evaluated by using search coils. The accuracy of measurement was verified with an amorphous metal ribbon sample. Next, we have measured magnetic properties of some magnetic shape memory alloys, which have different compositions. The measured results are compared and we clarified the effect of Sm contents on the magnetic properties

  14. Development of dual field magnetic flux leakage (MFL) inspection technology to detect mechanical damage.

    Science.gov (United States)

    2013-03-01

    This report details the development and testing of a dual magnetization in-line inspection (ILI) : tool for detecting mechanical damage in operating pipelines, including the first field trials of a : fully operational dual-field magnetic flux leakage...

  15. Development of High-Field Permanent Magnetic Circuits for NMRI/MRI and Imaging on Mice

    Science.gov (United States)

    Wang, Guangxin; Xie, Huantong; Hou, Shulian; Chen, Wei; Yang, Xiuhong

    2016-01-01

    The high-field permanent magnetic circuits of 1.2 T and 1.5 T with novel magnetic focusing and curved-surface correction are developed. The permanent magnetic circuit comprises a magnetic yoke, main magnetic steel, nonspherical curved-surface magnetic poles, plugging magnetic steel, and side magnetic steel. In this work, a novel shimming method is proposed for the effective correction of base magnetic field (B 0) inhomogeneities, which is based on passive shimming on the telescope aspheric cutting, grinding, and fine processing technology of the nonspherical curved-surface magnetic poles and active shimming adding higher-order gradient coils. Meanwhile, the magnetic resonance imaging dedicated alloy with high-saturation magnetic field induction intensity and high electrical resistivity is developed, and nonspherical curved-surface magnetic poles which are made of the dedicated alloy have very good anti-eddy-current effect. In addition, the large temperature coefficient problem of permanent magnet can be effectively controlled by using a high quality temperature controller and deuterium external locking technique. Combining our patents such as gradient coil, RF coil, and integration computer software, two kinds of small animal Micro-MRI instruments are developed, by which the high quality MRI images of mice were obtained. PMID:27034951

  16. submitter Development of a Superconducting Magnet for a Compact Cyclotron for Radioisotope Production

    CERN Document Server

    Garcia-Tabares, Luis; Calero, Jesus; Gutierrez, Jose L; Munilla, Javier; Obradors, Diego; Perez, Jose M; Toral, Fernando; Iturbe, Rafael; Minguez, Leire; Gomez, Jose; Rodilla, Elena; Bajko, Marta; Michels, Matthias; Berkowitz, Daniel; Haug, Friedrich

    2016-01-01

    The present paper describes the development process of a low critical temperature superconducting magnet to be installed in a compact cyclotron producing single-dose radioisotopes for clinical and preclinical applications. After a brief description of the accelerator, the magnet development process is described, starting from the magnetic, mechanical, quench, and thermal calculations, continuing with the designing process, particularly the support structure of the magnet and the cryogenic supply system, to finish with the fabrication and the first tests than have been performed.

  17. Research on magnetorheological damper suspension with permanent magnet and magnetic valve based on developed FOA-optimal control algorithm

    Energy Technology Data Exchange (ETDEWEB)

    Xiao, Ping; Gao, Hong [Anhui Polytechnic University, Wuhu (China); Niu, Limin [Anhui University of Technology, Maanshan (China)

    2017-07-15

    Due to the fail safe problem, it was difficult for the existing Magnetorheological damper (MD) to be widely applied in automotive suspensions. Therefore, permanent magnets and magnetic valves were introduced to existing MDs so that fail safe problem could be solved by the magnets and damping force could be adjusted easily by the magnetic valve. Thus, a new Magnetorheological damper with permanent magnet and magnetic valve (MDPMMV) was developed and MDPMMV suspension was studied. First of all, mechanical structure of existing magnetorheological damper applied in automobile suspensions was redesigned, comprising a permanent magnet and a magnetic valve. In addition, prediction model of damping force was built based on electromagnetics theory and Bingham model. Experimental research was onducted on the newly designed damper and goodness of fit between experiment results and simulated ones by models was high. On this basis, a quarter suspension model was built. Then, fruit Fly optimization algorithm (FOA)-optimal control algorithm suitable for automobile suspension was designed based on developing normal FOA. Finally, simulation experiments and bench tests with input surface of pulse road and B road were carried out and the results indicated that working erformance of MDPMMV suspension based on FOA-optimal control algorithm was good.

  18. Development of miniature moving magnet cryocooler SX040

    Science.gov (United States)

    Rühlich, I.; Mai, M.; Rosenhagen, C.; Schreiter, A.; Möhl, C.

    2011-06-01

    State of the art high performance cooled IR systems need to have more than just excellent E/O performance. Minimum size weight and power (SWaP) are the design goals to meet our forces' mission requirements. Key enabler for minimum SWaP of IR imagers is the operation temperature of the focal plane array (FPA) employed. State of the art MCT or InAsSb nBn technology has the potential to rise the FPA temperature from 77 K to 130-150 K (high operation temperature HOT) depending on the specific cut-off wavelength. Using a HOT FPA will significantly lower SWaP and keep those parameters finally dominated by the employed cryocooler. Therefore compact high performance cryocoolers are mandatory. For highest MTTF life AIM developed its Flexure Bearing Moving Magnet product family "SF". Such coolers achieve more than 20000 h MTTF with Stirling type expander and more than 5 years MTTF life with Pulse Tube coldfinger (like for Space applications). To keep the high lifetime potential but to significantly improve SWaP AIM is developing its "SX" type cooler family. The new SX040 cooler incorporates a highly efficient dual piston Moving Magnet driving mechanism resulting in very compact compressor of less than 100mm length. The cooler's high lifetime is also achieved by placing the coils outside the helium vessel as usual for moving magnet motors. The mating ¼" expander is extremely compact with less than 63 mm length. This allows a total dewar length from optical window to expander warm end of less than 100 mm even for large cold shields. The cooler is optimized for HOT detectors with operating temperatures exceeding 95 K. While this kind of cooler is the perfect match for many applications, handheld sights or targeting devices for the dismounted soldier are even more challenging with respect to SWaP. AIM therefore started to develop an even smaller cooler type with single piston and balancer. This paper gives an overview on the development of this new compact cryocooler. Technical

  19. Voltammetric behavior of sedative drug midazolam at glassy carbon electrode in solubilized systems

    OpenAIRE

    Jain, Rajeev; Yadav, Rajeev Kumar

    2012-01-01

    Redox behavior of midazolam was studied at a glassy carbon electrode in various buffer systems, supporting electrolytes and pH using differential pulse, square-wave and cyclic voltammetry. Based on its reduction behavior, a direct differential pulse voltammetric method has been developed and validated for the determination of midazolam in parenteral dosage. Three well-defined peaks were observed in 0.1% SLS, BrittonâRobinson (BR) buffer of pH 2.5. The effect of surfactants like sodium lauryl ...

  20. Voltammetric behavior of sedative drug midazolam at glassy carbon electrode in solubilized systems

    OpenAIRE

    Jain, Rajeev; Yadav, Rajeev Kumar

    2011-01-01

    Redox behavior of midazolam was studied at a glassy carbon electrode in various buffer systems, supporting electrolytes and pH using differential pulse, square-wave and cyclic voltammetry. Based on its reduction behavior, a direct differential pulse voltammetric method has been developed and validated for the determination of midazolam in parenteral dosage. Three well-defined peaks were observed in 0.1% SLS, Britton–Robinson (BR) buffer of pH 2.5. The effect of surfactants like sodium lauryl ...

  1. Polymorphic ethyl alcohol as a model system for the quantitative study of glassy behaviour

    Energy Technology Data Exchange (ETDEWEB)

    Fischer, H.E.; Schober, H.; Gonzalez, M.A. [Institut Max von Laue - Paul Langevin (ILL), 38 - Grenoble (France); Bermejo, F.J.; Fayos, R.; Dawidowski, J. [Consejo Superior de Investigaciones Cientificas, Madrid (Spain); Ramos, M.A.; Vieira, S. [Universidad Autonoma de Madrid (Spain)

    1997-04-01

    The nearly universal transport and dynamical properties of amorphous materials or glasses are investigated. Reasonably successful phenomenological models have been developed to account for these properties as well as the behaviour near the glass-transition, but quantitative microscopic models have had limited success. One hindrance to these investigations has been the lack of a material which exhibits glass-like properties in more than one phase at a given temperature. This report presents results of neutron-scattering experiments for one such material ordinary ethyl alcohol, which promises to be a model system for future investigations of glassy behaviour. (author). 8 refs.

  2. Linear response in aging glassy systems, intermittency and the Poisson statistics of record fluctuations

    DEFF Research Database (Denmark)

    Sibani, Paolo

    2007-01-01

    in a correlated fashion and through irreversible bursts, `quakes', which punctuate reversible and equilibrium-like fluctuations of zero average. The temporal distribution of the quakes is a Poisson distribution with an average growing logarithmically on time, indicating that the quakes are triggered by record...... to capture the time dependencies of the EA simulation results. Finally, we argue that whenever the changes of the linear response function and of its conjugate autocorrelation function follow from the same intermittent events a fluctuation-dissipation-like relation can arise between the two in off......We study the intermittent behavior of the energy decay and the linear magnetic response of a glassy system during isothermal aging after a deep thermal quench, using the Edward-Anderson spin glass model as a paradigmatic example. The large intermittent changes in the two observables occur...

  3. Mathematical developments regarding the general theory of the Earth magnetism

    Science.gov (United States)

    Schmidt, A.

    1983-01-01

    A literature survey on the Earth's magnetic field, citing the works of Gauss, Erman-Petersen, Quintus Icilius and Neumayer is presented. The general formulas for the representation of the potential and components of the Earth's magnetic force are presented. An analytical representation of magnetic condition of the Earth based on observations is also made.

  4. Materials Development for Thermally-Assisted Magnetic Recording Media

    Science.gov (United States)

    2001-04-01

    theory of superparamagnetism establishes a minimum magnetic particle volume for stability of the particle’s magnetization at temperature T...limit. And yet, one can envision medium coercivity rising toward 100 kilo- oersted using known materials [4]. Thus, a writability crisis in magnetic

  5. Latest developments at the ALBA magnetic measurements laboratory

    Science.gov (United States)

    Marcos, J.; Massana, V.; García, L.; Campmany, J.

    2018-02-01

    ALBA is a third-generation synchrotron light source that has been in operation since 2012 near Barcelona. A magnetic measurements laboratory has been associated with the facility since its very early stages and has been active for the last 20 years. In the first part of this work, the different instruments available at the laboratory are described, and a brief overview of the measurement campaigns carried out during its 20 years of history is presented. In the second part, a more detailed description of the approach to Hall probe measurements adopted at ALBA is offered, with an explanation of the methods and ancillary equipment that have been developed along the years in order to improve the accuracy of the system. In the third part, a new concept of Hall probe bench devoted to the measurement of closed structures is presented. The in-house design and building of a prototype for such a bench is described, together with its mechanical and magnetic characterization. As a conclusion, the first results obtained with this bench are discussed.

  6. Magnetic excitations in soft X-ray RIXS: Recent developments

    International Nuclear Information System (INIS)

    Fatale, S.; Moser, S.; Grioni, M.

    2015-01-01

    Highlights: • We give an overview of recent developments in resonant inelastic X-ray scattering (RIXS) with soft X-rays. • We briefly discuss the RIXS process at the L edges of 3d transition metal compounds. • We review RIXS data on magnetic excitations in insulating and superconducting cuprates. • We briefly discuss RIXS results on 1D oxides, iron-based superconductors and iridates. - Abstract: Resonant inelastic X-ray scattering (RIXS) has rapidly become a mature spectroscopic technique. In particular, taking advantage of an improved energy resolution, a series of experiments performed over the past 5 years have established soft X-ray RIXS as a sensitive, quantitative tool to investigate magnetic excitations in solids, complementary to more traditional probes such as neutron scattering. Most of the work has targeted cuprate systems, and the focus has progressively shifted from the antiferromagnetic insulating parent compounds to the superconducting part of the phase diagram. Here we review the most recent results, and the outstanding questions they raise.

  7. Superconducting magnet development. Program annual report, July 1975--September 1976

    Energy Technology Data Exchange (ETDEWEB)

    Deis, D.W.; Cornish, D.N.; Zbasnik, J.P.; Nelson, R.L.; Sackett, S.J.; Taylor, C.E.

    1977-07-22

    During FY76 Lawrence Livermore Laboratory (LLL) continued its development of niobium tin (Nb/sub 3/Sn) conductors and its design support for the mirror fusion test facility (MFTF) superconducting magnet. Three highlights came from within the Laboratory. LLL completed its cryogenic tensile-test apparatus for NB/sub 3/Sn strain measurements. Over at MFTF, engineers ordered 2100 m of prototype material for a 1-m test coil. People at the high-field test facility (HFTF) released some components for fabrication; delivery was scheduled for early FY77. Outside LLL several subcontractors advanced Nb/sub 3/Sn manufacturing technology. One advance, in particular, improved conductor current densities at 12 T.

  8. Development of motion capture system using alternating magnetic field

    Science.gov (United States)

    Kumagai, Masaaki; Akamatsu, Kazuyoshi

    2005-12-01

    Motion capture systems are widely used for virtual reality, motion acquisition for medical researches, for humanoid robots, for video games, etc. Several types of them have been developed and used for applications considering their advantages and restrictions. Another type of motion capture system that uses alternating magnetic field is proposed in this paper. The system uses a field exciting coil that covers measuring area and a pickup coil attached to target. First, six alternating fields are generated simultaneously in measuring area, and signals are induced on pickup coils according to attitude and position of it. These signals are processed to extract amplitude of exciting components, and state of the pickup coil is calculated from those components. It can detect attitude and displacement of target with high resolution and fast response speed. The principles of detection and brief experimental results are described.

  9. Development of cutting technique of magnetic alloys core

    International Nuclear Information System (INIS)

    Nomura, Masahiro; Tamura, Fumihiko; Schnase, Alexander; Yamamoto, Masanobu; Anami, Shozo; Ezura, Eizi; Hara, Keigo; Ohmori, Chihiro; Takagi, Akira; Yoshii, Masahito

    2005-01-01

    A new type of rf cavity using a high permeability magnetic alloy (MA) will be used for the J-PARC high intense proton synchrotrons. The cut core configuration has been adopted to get the optimum Q-value of MA core. We observed the cut surface of MA cores obtained by water jet and grind stone cut. The results show that the roughness of the cut surfaces by grind stone cut is much smaller than by water jet cut so that the cut core by grind stone cut has a possibility to reduce the temperature rise around the cut surface. We developed a grind stone cutting machine for large core and cut large cores by using this machine. High power test of those cores have been performed and we did not observe the temperature rise around the cut surface. (author)

  10. Status of tritium technology development for magnetic-fusion energy

    International Nuclear Information System (INIS)

    Anderson, J.L.

    1983-01-01

    The development of tritium technology for the magnetic fusion energy program has progressed at a rapid rate over the past two years. The focal points for this development in the United States have been the Tritium Systems Test Assembly at Los Alamos and the FED/INTOR studies supported by the Fusion Engineering Design Center at Oak Ridge. In Canada the Canadian Fusion Fuel Technology Project has been initiated and promises to make significant contributions to the tritium technology program in the next few years. The Japanese government has now approved funding for the Tritium Processing Laboratory at the Japan Atomic Energy Research Institute's Tokai Research Establishment. Construction on this new facility is scheduled to begin in April 1983. This facility will be the center for fusion tritium technology development in Japan. The European Community is currently working on the design of the tritium facility for the Joint European Torus. There is considerable interaction between all of these programs, thus accelerating the overall development of this crucial technology

  11. Development and application of superconducting magnet for gyrotron with 4 mm wave length

    International Nuclear Information System (INIS)

    Zhu Xuewu; Pu Men; Chen Jian; Liu Jianmin; Shi Qingju

    1989-01-01

    A superconducting magnet for gyrotron with 4 mm wave legnth is developed, its main magnetic field reaches 3 T. The gyrotron combined with the magnet producesfundamental wave long pulse, its power is more than 60 kW, pulse duration 10 ∼ 20 ms, frequency 70 GHz. It is used for plasma preionization experiment on HL-1 Tokamak

  12. Development of High-frequency Soft Magnetic Materials for Power Electronics

    Directory of Open Access Journals (Sweden)

    LIU Jun-chang

    2017-05-01

    Full Text Available The new requirements of high-frequency magnetic properties are put forward for electronic components with the rapid development of power electronics industry and the use of new electromagnetic materials. The properties of magnetic core, which is the key unit of electronic components, determine the performance of electronic components directly. Therefore, it's necessary to study the high-frequency soft magnetic materials. In this paper, the development history of four types of soft magnetic materials was reviewed. The advantages and disadvantages of each kind of soft magnetic materials and future development trends were pointed out. The emphases were placed on the popular soft magnetic composite materials in recent years. The tendency is to develop high-frequency soft magnetic composite materials with the particle size controllable, uniform coating layer on the core and a mass production method from laboratory to industrialization.

  13. Voltammetric quantitation of nitazoxanide by glassy carbon electrode

    Directory of Open Access Journals (Sweden)

    Rajeev Jain

    2013-12-01

    Full Text Available The present study reports voltammetric reduction of nitazoxanide in Britton–Robinson (B–R buffer by cyclic and square-wave voltammetry at glassy carbon electrode. A versatile fully validated voltammetric method for quantitative determination of nitazoxanide in pharmaceutical formulation has been proposed. A squrewave peak current was linear over the nitazoxanide concentration in the range of 20–140 µg/mL. The limit of detection (LOD and limit of quantification (LOQ was calculated to be 5.23 μg/mL and 17.45 μg/mL, respectively. Keywords: Nitazoxanide, Squarewave voltammetry, Glassy carbon electrode, Pharmaceutical formulation

  14. Electrocatalytic hydrazine oxidation on quinizarine modified glassy carbon electrode

    Energy Technology Data Exchange (ETDEWEB)

    Ardakani, Mohammad Mazloum [Department of Chemistry, Faculty of Science, Yazd University, Yazd (Iran, Islamic Republic of)]. E-mail: mazloum@yazduni.ac.ir; karami, Payam Ebrahimi [Department of Chemistry, Faculty of Science, Yazd University, Yazd (Iran, Islamic Republic of); Rahimi, Parvaneh [Department of Chemistry, Faculty of Science, Yazd University, Yazd (Iran, Islamic Republic of); Zare, Hamid Reza [Department of Chemistry, Faculty of Science, Yazd University, Yazd (Iran, Islamic Republic of); Naeimi, Hossein [Department of Chemistry, Faculty of Science, Kashan University, Kashan (Iran, Islamic Republic of)

    2007-06-10

    The electrocatalytic oxidation of hydrazine has been studied on glassy carbon modified by electrodeposition of quinizarine, using cyclic voltammetry and chronoamperometry techniques. It has been shown that the oxidation of hydrazine to nitrogen occurs at a potential where oxidation is not observed at the bare glassy carbon electrode. The apparent charge transfer rate constant and transfer coefficient for electron transfer between the electrode surface and immobilized quinizarine were calculated as 4.44 s{sup -1} and 0.66, respectively. The heterogenous rate constant for oxidation of hydrazine at the quinizarine modified electrode surface was also determined and found to be about 4.83 x 10{sup 3} M{sup -1} s{sup -1}. The diffusion coefficient of hydrazine was also estimated as 1.1 x 10{sup -6} cm{sup 2} s{sup -1} for the experimental conditions, using chronoamperometry.

  15. Development of large bore superconducting magnet for wastewater treatment application

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Hui Ming; Xu, Dong; Shen, Fuzhi; Zhang, Hengcheng; Li, Lafeng [State Key Laboratory of Technologies in Space Cryogenic Propellants, Technical Institute of Physics and Chemistry, Chinese Academy of Sciences, Beijing (China)

    2017-03-15

    Water issue, especially water pollution, is a serious issue of 21st century. Being an significant technique for securing water resources, superconducting magnetic separation wastewater system was indispensable. A large bore conduction-cooled magnet was custom-tailored for wastewater treatment. The superconducting magnet has been designed, fabricated and tested. The superconducting magnet was composed of NbTi solenoid coils with an effective horizontal warm bore of 400 mm and a maximum central field of 2.56T. The superconducting magnet system was cooled by a two-stage 1.5W 4K GM cryocooler. The NbTi solenoid coils were wound around an aluminum former that is thermally connected to the second stage cold head of the cryocooler through a conductive copper link. The temperature distribution along the conductive link was measured during the cool-down process as well as at steady state. The magnet was cooled down to 4.8K in approximately 65 hours. The test of the magnetic field and quench analysis has been performed to verify the safe operation for the magnet system. Experimental results show that the superconducting magnet reached the designed magnetic performance.

  16. Study of lithium glassy solid electrolyte/electrode interface by ...

    Indian Academy of Sciences (India)

    Unknown

    Cells of lithium ion conducting glassy electrolyte Li2SO4–Li2O–B2O3 with different combinations of electrodes (stainless steel blocking electrode, lithium non-blocking electrode and TiS2 electrode) have been pre- pared. The a.c. impedance ... tant requirements for the solid state battery to achieve high current density, more ...

  17. Insecticides sought to control adult glassy-winged sharpshooter

    OpenAIRE

    Akey, David H.; Henneberry, Thomas J.; Toscano, Nick

    2001-01-01

    The bacterium that causes Pierce's disease (Xylella fastidiosa) is transmitted to grapevines by the glassy-winged sharpshooter (GWSS). Insecticides were evaluated for efficacy and residual activity against adult GWSS on grapevines. Ten insecticides were tested in the cyclo-chlorinated, carbamate, organic phosphate, pyrethroid and neonicotinoid chemical classes. Results from field trials indicate that the pyrethroids and neonicotinoids are promising control agents. Information on efficacious a...

  18. In situ Raman spectroelectrochemistry of azobenzene monolayers on glassy carbon.

    Science.gov (United States)

    Itoh, Takashi; McCreery, Richard L

    2007-05-01

    In situ Raman spectra of chemisorbed azobenzene (AB) monolayers on glassy carbon (GC) electrodes were observed under potentiostatic conditions in acetonitrile (ACN) with tetrabutyl-ammonium tetrafluoroborate (TBA-BF4). The Raman intensities of these spectra were high below -1000 mV, and this is attributed to the change in absorbance of AB on GC. In this paper, we describe chemisorbed AB molecules on GC electrode surfaces under potentiostatic conditions.

  19. Glassy selenium at high pressure: Le Chatelier's principle still works

    Science.gov (United States)

    Brazhkin, V. V.; Tsiok, O. B.

    2017-10-01

    Selenium is the only easily vitrified elementary substance. Numerous experimental studies of glassy Se (g -Se) at high pressures show a large spread in the data on the compressibility and electrical resistivity of g -Se. Furthermore, H. Liu et al. [Proc. Natl. Acad. Sci. USA 105, 13229 (2008), 10.1073/pnas.0806857105] have arrived at the surprising conclusion that the volume of glass increases during pressure-induced crystallization. We have performed high-precision measurements of the specific volume and electrical resistivity of glassy selenium (g -Se) at high hydrostatic pressures up to 9 GPa. The measured bulk modulus at normal pressure is B =(9.0 5 ±0.15 ) GPa and its pressure derivative is BP'=6.4 ±0.2 . In the pressure range P <3 GPa, glassy selenium has an anomalously large negative second derivative of the bulk modulus. The electrical resistivity of g -Se decreases almost exponentially with increasing pressure and reaches 20 Ω cm at a pressure of 8.75 GPa. The inelastic behavior and weak relaxation of the volume for g -Se begin at pressures above 3.5 GPa; the volume and logarithm of the electrical resistivity relax significantly (logarithmically with the time) at pressures above 8 GPa. Bulk measurements certainly indicate that the volume of g -Se glass in the crystallization pressure range is larger than the volumes of both appearing crystalline phases (by 2% and 4%). Therefore, the "volume expansion phenomenon" suggested in [H. Liu et al., Proc. Natl. Acad. Sci. USA 105, 13229 (2008), 10.1073/pnas.0806857105] is not observed, and the pressure-induced crystallization of glassy selenium is consistent with the laws of thermodynamics.

  20. Eddy current probe development based on a magnetic sensor array

    International Nuclear Information System (INIS)

    Vacher, F.

    2007-06-01

    This research deals with in the study of the use of innovating magnetic sensors in eddy current non destructive inspection. The author reports an analysis survey of magnetic sensor performances. This survey enables the selection of magnetic sensor technologies used in non destructive inspection. He presents the state-of-the-art of eddy current probes exploiting the qualities of innovating magnetic sensors, and describes the methods enabling the use of these magnetic sensors in non destructive testing. Two main applications of innovating magnetic sensors are identified: the detection of very small defects by means of magneto-resistive sensors, and the detection of deep defects by means of giant magneto-impedances. Based on the use of modelling, optimization, signal processing tools, probes are manufactured for these both applications

  1. States of Water in Non-Equilibrium Glassy Polymers

    Science.gov (United States)

    Davis, Eric; Elabd, Yossef

    2013-03-01

    For many applications (e.g., packaging, medical devices) a deeper fundamental understanding of the molecular nature of water in glassy polymer coatings is of significant interest. In this study, the sorption and diffusion of water in two glassy polymers, poly(methyl methacrylate) (PMMA) and poly(styrene) (PS), were measured with both quartz crystal microbalance (QSM) and time-resolved Fourier transform infrared-attenuated total reflectance (FTIR-ATR) spectroscopy. Non-Fickian diffusion was observed in both PMMA and PS using both experimental techniques due to the non-equilibrium state of the polymers. The specific states of water were observed with FTIR-ATR spectroscopy, where dimers exist in PMMA below a critical concentration and larger clusters were observed above this concentration. Contrastingly, water only exists in PS as larger clusters over the entire sorption isotherm. A correlation between the states of water and the diffusive activation energy of water was observed. Additionally, the pseudo-equilibrium water sorption isotherms in PMMA and PS were accurately predicted with the non-equilibrium statistical associating fluid theory (NE-SAFT). We predict that the combination of time-resolved FTIR-ATR spectroscopy and NE-SAFT can be used on other water-glassy polymer systems to provide a molecular understanding of non-equilibrium sorption and diffusion.

  2. Non-Equilibrium Water-Glassy Polymer Dynamics

    Science.gov (United States)

    Davis, Eric; Minelli, Matteo; Baschetti, Marco; Sarti, Giulio; Elabd, Yossef

    2012-02-01

    For many applications (e.g., medical implants, packaging), an accurate assessment and fundamental understanding of the dynamics of water-glassy polymer interactions is of great interest. In this study, sorption and diffusion of pure water in several glassy polymers films, such as poly(styrene) (PS), poly(methyl methacrylate) (PMMA), poly(lactide) (PLA), were measured over a wide range of vapor activities and temperatures using several experimental techniques, including quartz spring microbalance (QSM), quartz crystal microbalance (QCM), and time-resolved Fourier transform infrared-attenuated total reflectance (FTIR-ATR) spectroscopy. Non-Fickian behavior (diffusion-relaxation phenomena) was observed by all three techniques, while FTIR-ATR spectroscopy also provides information about the distribution of the states of water and water transport mechanisms on a molecular-level. Specifically, the states of water are significantly different in PS compared to PMMA and PLA. Additionally, a purely predictive non-equilibrium lattice fluid (NELF) model was applied to predict the sorption isotherms of water in these glassy polymers.

  3. Electrochemical Determination of Caffeine Content in Ethiopian Coffee Samples Using Lignin Modified Glassy Carbon Electrode

    Directory of Open Access Journals (Sweden)

    Meareg Amare

    2017-01-01

    Full Text Available Lignin film was deposited at the surface of glassy carbon electrode potentiostatically. In contrast to the unmodified glassy carbon electrode, an oxidative peak with an improved current and overpotential for caffeine at modified electrode showed catalytic activity of the modifier towards oxidation of caffeine. Linear dependence of peak current on caffeine concentration in the range 6×10-6 to 100×10-6 mol L−1 with determination coefficient and method detection limit (LoD = 3 s/slope of 0.99925 and 8.37×10-7 mol L−1, respectively, supplemented by recovery results of 93.79–102.17% validated the developed method. An attempt was made to determine the caffeine content of aqueous coffee extracts of Ethiopian coffees grown in four coffee cultivating localities (Wonbera, Wolega, Finoteselam, and Zegie and hence to evaluate the correlation between users preference and caffeine content. In agreement with reported works, caffeine contents (w/w% of 0.164 in Wonbera coffee; 0.134 in Wolega coffee; 0.097 in Finoteselam coffee; and 0.089 in Zegie coffee were detected confirming the applicability of the developed method for determination of caffeine in a complex matrix environment. The result indicated that users’ highest preference for Wonbera and least preference for Zegie cultivated coffees are in agreement with the caffeine content.

  4. Investigation of glassy state molecular motions in thermoset polymers

    Science.gov (United States)

    Tu, Jianwei

    This dissertation presents the investigation of the glassy state molecular motions in isomeric thermoset epoxies by means of solid-state deuterium (2H) NMR spectroscopy technique. The network structure of crosslinked epoxies was altered through monomer isomerism; specifically, diglycidyl ether of bisphenol A (DGEBA) was cured with isomeric amine curatives, i.e., the meta-substituted diaminodiphenylsulfone (33DDS) and para-substituted diaminodiphenylsulfone (44DDS). The use of structural isomerism provided a path way for altering macroscopic material properties while maintaining identical chemical composition within the crosslinked networks. The effects of structural isomerism on the glassy state molecular motions were studied using solid-state 2H NMR spectroscopy, which offers unrivaled power to monitor site-specific molecular motions. Three distinctive molecular groups on each isomeric network, i.e., the phenylene rings in the bisphenol A structure (BPA), the phenylene rings in the diaminodiphenylsulfone structure (DDS), and the hydroxypropoyl ether group (HPE) have been selectively deuterated for a comprehensive study of the structure-dynamics- property relationships in thermoset epoxies. Quadrupolar echo experiments and line shape simulations were employed as the main research approach to gain both qualitative and quantitative motional information of the epoxy networks in the glassy state. Quantitative information on the geometry and rate of the molecular motions allows the elucidation of the relationship between molecular motions and macro physical properties and the role of these motions in the mechanical relaxation. Specifically, it is revealed that both the BPA and HPE moieties in the isomeric networks have almost identical behaviors in the deep glassy state, which indicates that the molecular motions in the glassy state are localized, and the correlation length of the motions does not exceed the length of the DGEBA repeat unit. BPA ring motions contribute

  5. New developments in pulsed fields at the US National High Magnetic Field Laboratory

    International Nuclear Information System (INIS)

    Campbell, L.J.; Parkin, D.M.; Rickel, D.G.; Pernambuco-Wise, P.

    1996-01-01

    Los Alamos National Laboratory is a member of a consortium (with Florida State University and the University of Florida) to operate the National High Magnetic Field Laboratory (NHMFL), with funding from the National Science Foundation and the State of Florida. Los Alamos provides unique resources for its component of NHMFL in the form of a 1.4 GW inertial storage motor-generator for high field pulsed magnets and infrastructure for fields generated by flux compression. The NHMFL provides a user facility open to all qualified users, develops magnet technology in association with the private sector, and advances science and technology opportunities. The magnets in service at Los Alamos are of three types. Starting with the pre-existing explosive flux compression capability in 1991, NHMFL added capacitor-driven magnets in December, 1992, and a 20 tesla superconducting magnet in January, 1993. The capacitor-driven magnets continue to grow in diversity and accessibility, with four magnet stations now available for several different magnet types. Two magnets of unprecedented size and strength are nearing completion of assembly and design, respectively. Under final assembly is a quasi-continuous magnet that contains 90 MJ of magnetic energy at full field, and being designed is a non-destructive 100 T magnet containing 140 MJ

  6. Development of advanced biorefinery concepts using magnetically responsive materials

    Czech Academy of Sciences Publication Activity Database

    Šafařík, Ivo; Pospišková, K.; Baldíková, E.; Šafaříková, Miroslava

    2016-01-01

    Roč. 116, DEC (2016), s. 17-26 ISSN 1369-703X R&D Projects: GA ČR GA13-13709S Institutional support: RVO:67179843 Keywords : saccharomyces-cerevisiae cells * solid acid catalysts * Separation * Biocatalysis * Immobilization * Bioconversion * Magnetic particles * Magnetic enzymes and cells Subject RIV: EH - Ecology, Behaviour Impact factor: 2.892, year: 2016

  7. Development of advanced biorefinery concepts using magnetically responsive materials

    Czech Academy of Sciences Publication Activity Database

    Šafařík, Ivo; Pospíšková, K.; Baldíková, E.; Šafaříková, Miroslava

    2016-01-01

    Roč. 116, SI (2016), s. 17-26 ISSN 1369-703X Institutional support: RVO:60077344 Keywords : separation * biocatalysis * immobilization * bioconversion * magnetic particles * magnetic enzymes and cells Subject RIV: GM - Food Processing Impact factor: 2.892, year: 2016

  8. Development of a high-performance magnetic gear

    DEFF Research Database (Denmark)

    Rasmussen, Peter Omand; Andersen, Torben Ole; Jørgensen, Frank Thorleif

    2005-01-01

    This paper presents calculation and measurement results of a highperformance permanent-magnetic gear. The analyzed permanent-magnetic gear has a gear ratio of 5.5 and is able to deliver 27 N.m. The analysis has shown that special attention needs to be paid to the system where the gear is to be in...

  9. Development of a temperature-variable magnetic resonance imaging system using a 1.0T yokeless permanent magnet.

    Science.gov (United States)

    Terada, Y; Tamada, D; Kose, K

    2011-10-01

    A temperature variable magnetic resonance imaging (MRI) system has been developed using a 1.0 T permanent magnet. A permanent magnet, gradient coils, radiofrequency coil, and shim coil were installed in a temperature variable thermostatic bath. First, the variation in the magnetic field inhomogeneity with temperature was measured. The inhomogeneity has a specific spatial symmetry, which scales linearly with temperature, and a single-channel shim coil was designed to compensate for the inhomogeneity. The inhomogeneity was drastically reduced by shimming over a wide range of temperature from -5°C to 45°C. MR images of an okra pod acquired at different temperatures demonstrated the high potential of the system for visualizing thermally sensitive properties. Copyright © 2011 Elsevier Inc. All rights reserved.

  10. MAGNET

    CERN Multimedia

    by B. Curé

    2011-01-01

    The magnet operation was very satisfactory till the technical stop at the end of the year 2010. The field was ramped down on 5th December 2010, following the successful regeneration test of the turbine filters at full field on 3rd December 2010. This will limit in the future the quantity of magnet cycles, as it is no longer necessary to ramp down the magnet for this type of intervention. This is made possible by the use of the spare liquid Helium volume to cool the magnet while turbines 1 and 2 are stopped, leaving only the third turbine in operation. This obviously requires full availability of the operators to supervise the operation, as it is not automated. The cryogenics was stopped on 6th December 2010 and the magnet was left without cooling until 18th January 2011, when the cryoplant operation resumed. The magnet temperature reached 93 K. The maintenance of the vacuum pumping was done immediately after the magnet stop, when the magnet was still at very low temperature. Only the vacuum pumping of the ma...

  11. Determination of trace amounts of lead and cadmium using a bismuth/glassy carbon composite electrode.

    Science.gov (United States)

    Hwang, Gil-Ho; Han, Won-Kyu; Hong, Seok-Jun; Park, Joon-Shik; Kang, Sung-Goon

    2009-02-15

    We examined the use of a bismuth-glassy carbon (Bi/C) composite electrode for the determination of trace amounts of lead and cadmium. Incorporated bismuth powder in the composite electrode was electrochemically dissolved in 0.1M acetate buffer (pH 4.5) where nanosized bismuth particles were deposited on the glassy carbon at the reduction potential. The anodic stripping voltammetry on the Bi/C composite electrode exhibited well-defined, sharp and undistorted peaks with a favorable resolution for lead and cadmium. Comparing a non-oxidized Bi/C composite electrode with an in-situ plated bismuth film electrode, the Bi/C composite electrode exhibited superior performance due to its much larger surface area. The limit of detection was 0.41 microg/L for lead and 0.49 microg/L for cadmium. Based on this study, we are able to conclude that various types of composite electrodes for electroanalytical applications can be developed with a prudent combination of electrode materials.

  12. Novel electroanalysis of hydroxyurea at glassy carbon and gold electrode surfaces

    Directory of Open Access Journals (Sweden)

    Keerti M. Naik

    2014-09-01

    Full Text Available A simple and a novel electroanalysis of hydroxyurea (HU drug at glassy carbon and gold electrode was investigated for the first time using cyclic, linear sweep and differential pulse voltammetric techniques. The oxidation of HU was irreversible and exhibited a diffusion controlled process on both electrodes. The oxidation mechanism was proposed. The dependence of the current on pH, the concentration, nature of buffer, and scan rate was investigated to optimize the experimental conditions for the determination of HU. It was found that the optimum buffer pH was 7.0, a physiological pH. In the range of 0.01 to 1.0 mM, the current measured by differential pulse voltammetry showed a linear relationship with HU concentration with limit of detection of 0.46 µM for glassy carbon electrode and 0.92 µM for gold electrode. In addition, reproducibility, precision and accuracy of the method were checked as well. The developed method was successfully applied to HU determination in pharmaceutical formulation and human biological fluids. The method finds its applications in quality control laboratories and pharmacokinetics.

  13. Applied CATIA Secondary Development to Parametric Design of Active Magnetic Bearing

    Directory of Open Access Journals (Sweden)

    Zhang Li

    2016-01-01

    Full Text Available Based on the properties of active magnetic bearing, the electromagnetic parameters and structure parameters are analyzed, parametric design method is introduced to study the structure of active magnetic bearing. Through a program personalization process that is in accordance with active magnetic bearing is established. Personalization process aims to build the parametric model of active magnetic bearings and component library by use of CATIA secondary development. Component library is to build assembly model for a multiple degree of freedom magnetic bearing system. Parametric design is a method that provides the direction for its structural design.

  14. Phosphorus magnetic resonance spectroscopy in malformations of cortical development

    Directory of Open Access Journals (Sweden)

    Celi Santos Andrade

    2013-07-01

    Full Text Available Introduction Malformations of cortical development (MCD result from disruptions in the dynamic process of cerebral corticogenesis and are important causes of epilepsy, motor deficits and cognitive impairment. Objectives The aim of this study was to evaluate phospholipids metabolism in vivo in a series of patients with epilepsy and MCD. Methods Thirty-seven patients with MCD and 31 control subjects were studied using three-dimensional phosphorus magnetic resonance spectroscopy (31P-MRS at a 3.0 T scanner. Quantification methods were applied to the following resonances: phosphoethanolamine (PE, phosphocholine (PC, glycerophosphoethanolamine (GPE, glycerophosphocholine (GPC, inorganic phosphate (Pi, phosphocreatine (PCr, and a-, b-, and g-adenosine triphosphate (ATP. The magnesium (Mg2+ levels and pH were calculated based on PCr, Pi and b-ATP chemical shifts. Results Compared to controls, the MCD lesions exhibited lower pH values and higher Mg2+ levels (p<0.05. The lesions also presented significant reduction of GPC and PDE, and an increased PME/PDE ratio. The otherwise normal appearing parenchyma also demonstrated lower pH values in the frontoparietal cortex and bilateral centrum semiovale. Conclusions Our data support the idea that metabolic impairments occur in the lesions of MCD, with propagation to remote normal appearing parenchyma. The results also suggest that there are membrane turnover disturbances in MCD lesions.

  15. Research and development of an aimed magnetic lead current density-magnetic field diagnostic. Final report

    International Nuclear Information System (INIS)

    1985-01-01

    A diagnostics survey was made to provide a clear definition of advanced diagnostic needs and the limitations of current approaches in addressing those needs. Special attention was given to the adequacy with which current diagnostics are interfaced to signal processing/data acquisition devices and systems. Critical evaluations of selected alternative diagnostic techniques for future R and D activities are presented. The conceptual basis of the Aimed Magnetic Lead Gradiometric system as a current density/magnetic field diagnostic is established

  16. Recent developments toward understanding magnetization processes in Nd-Fe-B permanent magnet materials

    International Nuclear Information System (INIS)

    Hirosawa, S.; Fukagawa, T.; Maki, T.

    2007-01-01

    The quick rise of an enormous market of high-coercivity grades of Nd-Fe-B sintered magnets for hybrid electric vehicles (HEV) has created a new concern about resources of certain elements such as Tb and Dy which is used in order to guarantee stability of magnetic flux at operating temperatures. Accordingly, improvements of coercivity in the Nd-Fe-B magnets at elevated temperatures without heavily using these scarce elements are required. For this goal, deeper understanding of the coercivity mechanism is necessary. In order to clearly study the relationship between local microstructure and coercivity related to that microstructure, an approach using a model magnet composed of a thin sintered magnet and an Nd layer deposited on its surface is reported. Besides this micropscopic apporach, macroscopic approaches are also indepensable. Also described in this paper is investigation of successive recoil curves and their relation with magnetic domain structures in a system composed of submicron size grains of Nd 2 Fe 14 B that can be prepared by means of hydrogenation-disproportionation-dehydrogenation-decomposition process. (copyright 2008 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  17. Development and Demonstration of a Multiplexed Magnetic Tweezers Assay

    Science.gov (United States)

    Johnson, Keith Charles

    This dissertation is concerned with the methods and applications of single molecule force spectroscopy. In the introduction, the traditional single molecule force spectroscopy instruments are introduced and the advantages and drawbacks of each are discussed. The first chapter is a review of methods to ensure that biomolecular bond lifetime parameter estimations are not contaminated by multiple bond data. This review culminates in an examination of the literature on the strength of the bond between biotin and streptavidin and finds that by filtering the numerous publications for those that clearly demonstrate specific single bond behavior, there is a consensus of the bond strength and kinetic parameters. The second chapter of the dissertation discusses the capabilities of a magnetic tweezer assay, which combines massive multiplexing, precision bead tracking, and bi-directional force control into a flexible and stabile platform for examining single molecule behavior. Using a novel method for increasing the precision of force estimations on heterogeneous paramagnetic beads, I demonstrate the instrument by examining the force dependence of uncoiling and recoiling velocity of type 1 fimbriae from Eschericia coli (E. coli) bacteria, and see similar results to previous studies. Chapter 3 is a study of the lifetime of the activated FimH-mannose bond under various force conditions using the previously described magnetic tweezer. The bond is found to be extremely long-lived at forces less than 30 pN, with an average lifetime > 1000 times longer than the biotin-streptavidin bond, making it one of the strongest non-covalent interactions known in nature. Furthermore, the average lifetime of the bond is similar between 9 and 30 pN of force, suggesting a force range at which the lifetime is force-independent, demonstrating ideal bond behavior for the first time in a natural system. It is hypothesized that the long lifetime and ideal behavior is due to a gateway that locks mannose

  18. Glassy low-energy spin fluctuations and anisotropy gap in La1.88Sr0.12CuO4

    DEFF Research Database (Denmark)

    Rømer, A. T.; Chang, J.; Christensen, Niels Bech

    2013-01-01

    between the ordering temperature TN ≃ Tc inferred from elastic neutron scattering and the freezing temperature Tf ≃ 11 K obtained from muon spin rotation studies. The magnetic field independence of the observed excitation spectrum as well as the observation of a partial suppression of magnetic spectral...... that the significant enhancement in a magnetic field of nominally elastic incommensurate scattering is caused by strictly inelastic scattering-at least in the temperature range between Tf and Tc - which is not resolved in the present experiment. Combining the results obtained from our study of La1.88Sr0.12CuO4......We present high-resolution triple-axis neutron scattering studies of the high-temperature superconductorLa1.88Sr0.12CuO4 (Tc = 27 K). The temperature dependence of the low-energy incommensurate magnetic fluctuations reveals distinctly glassy features. The glassiness is confirmed by the difference...

  19. Development of a high-performance magnetic gear

    DEFF Research Database (Denmark)

    Rasmussen, Peter Omand; Andersen, Torben Ole; Jørgensen, Frank Thorleif

    2005-01-01

    This paper presents calculation and measurement results of a highperformance permanent-magnetic gear. The analyzed permanent-magnetic gear has a gear ratio of 5.5 and is able to deliver 27 N.m. The analysis has shown that special attention needs to be paid to the system where the gear...... is to be installed because of a low natural torsion spring constant. The analyzed gear was also constructed in practice in order to validate the analysis and predict the efficiency. The measured torque from the magnetic gear was only 16 N-m reduced by the large end-effects. A systematic analysis of the 1055...... in the bearings and jess end-effects caused by relative ly short stack, an impressive efficiency estimated at 96% can be obtained. Comparison with c1assical mechanical gears has shown that the magnetic gear has a bette r efficiency and a comparable torque per volume density. Finally, it is concluded...

  20. Developments in deep brain stimulation using time dependent magnetic fields

    Energy Technology Data Exchange (ETDEWEB)

    Crowther, L.J.; Nlebedim, I.C.; Jiles, D.C.

    2012-03-07

    The effect of head model complexity upon the strength of field in different brain regions for transcranial magnetic stimulation (TMS) has been investigated. Experimental measurements were used to verify the validity of magnetic field calculations and induced electric field calculations for three 3D human head models of varying complexity. Results show the inability for simplified head models to accurately determine the site of high fields that lead to neuronal stimulation and highlight the necessity for realistic head modeling for TMS applications.

  1. Gas Transport in Glassy Polymers: Prediction of Diffusional Time Lag

    Directory of Open Access Journals (Sweden)

    Matteo Minelli

    2018-02-01

    Full Text Available The transport of gases in glassy polymeric membranes has been analyzed by means of a fundamental approach based on the nonequilibrium thermodynamic model for glassy polymers (NET-GP that considers the penetrant chemical potential gradient as the actual driving force of the diffusional process. The diffusivity of a penetrant is thus described as the product of a purely kinetic quantity, the penetrant mobility, and a thermodynamic factor, accounting for the chemical potential dependence on its concentration in the polymer. The NET-GP approach, and the nonequilibrium lattice fluid (NELF model in particular, describes the thermodynamic behavior of penetrant/polymer mixtures in the glassy state, at each pressure or composition. Moreover, the mobility is considered to follow a simple exponential dependence on penetrant concentration, as typically observed experimentally, using only two adjustable parameters, the infinite dilution penetrant mobility L10 and the plasticization factor β, both determined from the analysis of the dependence of steady state permeability on upstream pressure. The available literature data of diffusional time lag as a function of penetrant upstream pressure has been reviewed and compared with model predictions, obtained after the values of the two model parameters (L10 and β, have been conveniently determined from steady state permeability data. The model is shown to be able to describe very accurately the experimental time lag behaviors for all penetrant/polymer pairs inspected, including those presenting an increasing permeability with increasing upstream pressure. The model is thus more appropriate than the one based on Dual Mode Sorption, which usually provides an unsatisfactory description of time lag and required an ad hoc modification.

  2. Design, Development & Functional Validation of Magnets system in support of 42 GHz Gyrotron in India

    Science.gov (United States)

    Pradhan, S.; Raj, P.; Prasad, U.; Ghate, M.; Khristi, Y.; Panchal, A.; Bhavsar, D.; Banudha, M.; Kedia, S.; Sharma, A. N.; Kanabar, D.; Parghi, B.

    2017-07-01

    A multi institutional initiative is underway towards the development of 42 GHz, 200 kW gyrotron system in India under the frame work of Department of Science and Technology, Government of India. Indigenous realization comprising of design, fabrication, prototypes and functional validations of an appropriate Magnet System is one of the primary technological objective of these initiatives. The 42 GHz gyrotron magnet system comprises of a warm gun magnet, a NbTi/Cu based high homogenous superconducting cavity magnet and three warm collector magnets. The superconducting cavity magnet has been housed inside a low loss cryostat. The magnet system has been designed in accordance with gyrotron physics and engineering considerations respecting highly homogenous spatial field profile as well as maintaining steep gradient as per the compression and velocity ratios between the emission and resonator regions. The designed magnet system further ensures the co-linearity of the magnetic axis with that of the beam axis with custom winding techniques apart from a smooth collection of beam with the collector magnet profiles. The designed magnets have been wound after several R & D validations. The superconducting magnet has been housed inside a low loss designed cryostat with in-built radial and axial alignment flexibilities to certain extent. The cryostat further houses liquid helium port, liquid nitrogen ports, current communication ports, ports for monitoring helium level and other instrumentations apart from over-pressure safety intensive burst disks etc. The entire magnet system comprising of warm and superconducting magnets has been installed and integrated in the Gyrotron test set-up. The magnet system has been aligned in both warm and when the superconducting cavity magnet is cold. The integrated geometric axes have been experimentally ensured as well as the field profiles have been measured with the magnets being charged. Under experimental conditions, all magnets including

  3. Design, Development & Functional Validation of Magnets system in support of 42 GHz Gyrotron in India

    Directory of Open Access Journals (Sweden)

    Pradhan S.

    2017-01-01

    Full Text Available A multi institutional initiative is underway towards the development of 42 GHz, 200 kW gyrotron system in India under the frame work of Department of Science and Technology, Government of India. Indigenous realization comprising of design, fabrication, prototypes and functional validations of an appropriate Magnet System is one of the primary technological objective of these initiatives. The 42 GHz gyrotron magnet system comprises of a warm gun magnet, a NbTi/Cu based high homogenous superconducting cavity magnet and three warm collector magnets. The superconducting cavity magnet has been housed inside a low loss cryostat. The magnet system has been designed in accordance with gyrotron physics and engineering considerations respecting highly homogenous spatial field profile as well as maintaining steep gradient as per the compression and velocity ratios between the emission and resonator regions. The designed magnet system further ensures the co-linearity of the magnetic axis with that of the beam axis with custom winding techniques apart from a smooth collection of beam with the collector magnet profiles. The designed magnets have been wound after several R & D validations. The superconducting magnet has been housed inside a low loss designed cryostat with in-built radial and axial alignment flexibilities to certain extent. The cryostat further houses liquid helium port, liquid nitrogen ports, current communication ports, ports for monitoring helium level and other instrumentations apart from over-pressure safety intensive burst disks etc. The entire magnet system comprising of warm and superconducting magnets has been installed and integrated in the Gyrotron test set-up. The magnet system has been aligned in both warm and when the superconducting cavity magnet is cold. The integrated geometric axes have been experimentally ensured as well as the field profiles have been measured with the magnets being charged. Under experimental conditions

  4. Microscale rheology of a soft glassy material close to yielding.

    Science.gov (United States)

    Jop, Pierre; Mansard, Vincent; Chaudhuri, Pinaki; Bocquet, Lydéric; Colin, Annie

    2012-04-06

    Using confocal microscopy, we study the flow of a model soft glassy material: a concentrated emulsion. We demonstrate the micro-macro link between in situ measured movements of droplets during the flow and the macroscopic rheological response of a concentrated emulsion, in the form of scaling relationships connecting the rheological "fluidity" with local standard deviation of the strain-rate tensor. Furthermore, we measure correlations between these local fluctuations, thereby extracting a correlation length which increases while approaching the yielding transition, in accordance with recent theoretical predictions. © 2012 American Physical Society

  5. Crystal-like nature of acoustic excitations in glassy ethanol

    International Nuclear Information System (INIS)

    Matic, A.; Engberg, D.; Boerjesson, L.; Masciovecchio, C.; Santucci, S.C.; Monaco, G.; Verbeni, R.

    2004-01-01

    We report on inelastic x-ray scattering experiments on crystalline and glassy phases of ethanol in order to directly compare the influence of disorder on high frequency acoustic excitations. We find that both the dispersion and the line-width of the longitudinal acoustic excitations in the glass are the same as in the polycrystal in the reciprocal space portion covering the 1st and 2nd Brillouin zones. The structural disorder is found to play little role apart from an intrinsic angular averaging, and the nature of these excitations must essentially be the same in both glass and poly crystal

  6. MAGNET

    CERN Multimedia

    B. Curé

    2012-01-01

      Following the unexpected magnet stops last August due to sequences of unfortunate events on the services and cryogenics [see CMS internal report], a few more events and initiatives again disrupted the magnet operation. All the magnet parameters stayed at their nominal values during this period without any fault or alarm on the magnet control and safety systems. The magnet was stopped for the September technical stop to allow interventions in the experimental cavern on the detector services. On 1 October, to prepare the transfer of the liquid nitrogen tank on its new location, several control cables had to be removed. One cable was cut mistakenly, causing a digital input card to switch off, resulting in a cold-box (CB) stop. This tank is used for the pre-cooling of the magnet from room temperature down to 80 K, and for this reason it is controlled through the cryogenics control system. Since the connection of the CB was only allowed for a field below 2 T to avoid the risk of triggering a fast d...

  7. MAGNET

    CERN Multimedia

    B. Curé

    2012-01-01

      The magnet was energised at the beginning of March 2012 at a low current to check all the MSS safety chains. Then the magnet was ramped up to 3.8 T on 6 March 2012. Unfortunately two days later an unintentional switch OFF of the power converter caused a slow dump. This was due to a misunderstanding of the CCC (CERN Control Centre) concerning the procedure to apply for the CMS converter control according to the beam-mode status at that time. Following this event, the third one since 2009, a discussion was initiated to define possible improvement, not only on software and procedures in the CCC, but also to evaluate the possibility to upgrade the CMS hardware to prevent such discharge from occurring because of incorrect procedure implementations. The magnet operation itself was smooth, and no power cuts took place. As a result, the number of magnetic cycles was reduced to the minimum, with only two full magnetic cycles from 0 T to 3.8 T. Nevertheless the magnet suffered four stops of the cryogeni...

  8. MAGNET

    CERN Multimedia

    Benoit Curé

    2010-01-01

    Operation of the magnet has gone quite smoothly during the first half of this year. The magnet has been at 4.5K for the full period since January. There was an unplanned short stop due to the CERN-wide power outage on May 28th, which caused a slow dump of the magnet. Since this occurred just before a planned technical stop of the LHC, during which access in the experimental cavern was authorized, it was decided to leave the magnet OFF until 2nd June, when magnet was ramped up again to 3.8T. The magnet system experienced a fault also resulting in a slow dump on April 14th. This was triggered by a thermostat on a filter choke in the 20kA DC power converter. The threshold of this thermostat is 65°C. However, no variation in the water-cooling flow rate or temperature was observed. Vibration may have been the root cause of the fault. All the thermostats have been checked, together with the cables, connectors and the read out card. The tightening of the inductance fixations has also been checked. More tem...

  9. Developement of a Light Attenuator Based on Glassy Reflections ...

    African Journals Online (AJOL)

    The light intensity control of a luminous source is a very important operation in many optical applications. Several types of light attenuator exploiting different optical phenomena like diffraction, absorption, and reflection exist and they differ principally in the maximum attenuation rate, the control range, the sensitivity and the ...

  10. DEVELOPEMENT OF A LIGHT ATTENUATOR BASED ON GLASSY ...

    African Journals Online (AJOL)

    30 juin 2012 ... many optical applications. Several types of light attenuator exploiting different optical phenomena like diffraction, absorption, and reflection ... En télécommunication optique à titre d'exemple, les réseaux WDM (multiplexage en longueur d'onde) sont utilisés pour véhiculer par fibre optique de l'information à ...

  11. Continuous development of current sheets near and away from magnetic nulls

    International Nuclear Information System (INIS)

    Kumar, Sanjay; Bhattacharyya, R.

    2016-01-01

    The presented computations compare the strength of current sheets which develop near and away from the magnetic nulls. To ensure the spontaneous generation of current sheets, the computations are performed congruently with Parker's magnetostatic theorem. The simulations evince current sheets near two dimensional and three dimensional magnetic nulls as well as away from them. An important finding of this work is in the demonstration of comparative scaling of peak current density with numerical resolution, for these different types of current sheets. The results document current sheets near two dimensional magnetic nulls to have larger strength while exhibiting a stronger scaling than the current sheets close to three dimensional magnetic nulls or away from any magnetic null. The comparative scaling points to a scenario where the magnetic topology near a developing current sheet is important for energetics of the subsequent reconnection.

  12. Fundamental study for development magnetic drug delivery system

    International Nuclear Information System (INIS)

    Hirota, Y.; Akiyama, Y.; Izumi, Y.; Nishijima, S.

    2009-01-01

    Side-effects and lowering effects by diffusion of drugs such as anticancer agents is one of the serious issues in medication. To solve this problem, it is necessary to control the drugs quantitatively, spatially and temporally within the human body. Magnetic drug delivery system (MDDS) is one of the technologies to make it possible, in which the ferromagnetic drug injected into the blood vessel is conducted to diseased part by external magnetic force. As a fundamental experiment, the accumulation experiment using ferromagnetic particles were performed with simulated capillary vessels composed of glass beads channels in this work. Additionally, accumulation calculation of ferromagnetic particles was conducted to check the validity of accumulation experiment. From these result, the 2D distribution of particle accumulation in the experiment corresponded with that of particle accumulation in the calculation. It was suggested that the proper position of magnet should be changed according to the depth of diseased part.

  13. Development of non-magnetic high manganese cryogenic steel for the construction of LHC project's superconducting magnet

    CERN Document Server

    Ozaki, Y; Kakihara, S; Shiraishi, M; Morito, N; Nohara, K

    2002-01-01

    High manganese steel (KHMN30L) as a cryogenic nonmagnetic material has been developed by Kawasaki Steel Corporation, which is designed for structural material for superconducting magnet in particle accelerator system. This steel satisfies the following requirements for the present use. 1) Low magnetic permeability: its relative magnetic permeability is lower than 1.002 throughout the range between 1.9 K and room temperature, and shows little temperature dependency which is the result of the highly elevated Neel temperature controlled by alloying composition design. 2) Low thermal expansion: its integrated contraction from room temperature to 4.2 K is as small as 0.18%. 3) Appropriate mechanical properties: yield strength and tensile strength can be adjusted to the desirable value by the manufacturing process condition without deteriorating physical properties. With these excellent properties, this steel is being supplied for nonmagnetic lamination of the cold mass of the LHC (Large Hadron Collider) supercondu...

  14. MAGNET

    CERN Multimedia

    B. Curé

    2013-01-01

      The magnet was operated without any problem until the end of the LHC run in February 2013, apart from a CERN-wide power glitch on 10 January 2013 that affected the CMS refrigerator, causing a ramp down to 2 T in order to reconnect the coldbox. Another CERN-wide power glitch on 15 January 2013 didn’t affect the magnet subsystems, the cryoplant or the power converter. At the end of the magnet run, the reconnection of the coldbox at 2.5 T was tested. The process will be updated, in particular the parameters of some PID valve controllers. The helium flow of the current leads was reduced but only for a few seconds. The exercise will be repeated with the revised parameters to validate the automatic reconnection process of the coldbox. During LS1, the water-cooling services will be reduced and many interventions are planned on the electrical services. Therefore, the magnet cryogenics and subsystems will be stopped for several months, and the magnet cannot be kept cold. In order to avoid unc...

  15. MAGNET

    CERN Multimedia

    Benoit Curé

    2010-01-01

    The magnet was successfully operated at the end of the year 2009 despite some technical problems on the cryogenics. The magnet was ramped up to 3.8 T at the end of November until December 16th when the shutdown started. The magnet operation met a few unexpected stops. The field was reduced to 3.5 T for about 5 hours on December 3rd due to a faulty pressure sensor on the helium compressor. The following day the CERN CCC stopped unintentionally the power converters of the LHC and the experiments, triggering a ramp down that was stopped at 2.7 T. The magnet was back at 3.8 T about 6 hours after CCC sent the CERN-wide command. Three days later, a slow dump was triggered due to a stop of the pump feeding the power converter water-cooling circuit, during an intervention on the water-cooling plant done after several disturbances on the electrical distribution network. The magnet was back at 3.8 T in the evening the same day. On December 10th a break occurred in one turbine of the cold box producing the liquid ...

  16. MAGNET

    CERN Multimedia

    B. Curé

    2011-01-01

    The CMS magnet has been running steadily and smoothly since the summer, with no detected flaw. The magnet instrumentation is entirely operational and all the parameters are at their nominal values. Three power cuts on the electrical network affected the magnet run in the past five months, with no impact on the data-taking as the accelerator was also affected at the same time. On 22nd June, a thunderstorm caused a power glitch on the service electrical network. The primary water cooling at Point 5 was stopped. Despite a quick restart of the water cooling, the inlet temperature of the demineralised water on the busbar cooling circuit increased by 5 °C, up to 23.3 °C. It was kept below the threshold of 27 °C by switching off other cooling circuits to avoid the trigger of a slow dump of the magnet. The cold box of the cryogenics also stopped. Part of the spare liquid helium volume was used to maintain the cooling of the magnet at 4.5 K. The operators of the cryogenics quickly restarted ...

  17. MAGNET

    CERN Multimedia

    B. Curé

    2012-01-01

      The magnet and its sub-systems were stopped at the beginning of the winter shutdown on 8th December 2011. The magnet was left without cooling during the cryogenics maintenance until 17th January 2012, when the cryoplant operation resumed. The magnet temperature reached 93 K. The vacuum pumping was maintained during this period. During this shutdown, the yearly maintenance was performed on the cryogenics, the vacuum pumps, the magnet control and safety systems, and the power converter and discharge lines. Several preventive actions led to the replacement of the electrovalve command coils, and the 20A DC power supplies of the magnet control system. The filters were cleaned on the demineralised water circuits. The oil of the diffusion pumps was changed. On the cryogenics, warm nitrogen at 343 K was circulated in the cold box to regenerate the filters and the heat exchangers. The coalescing filters have been replaced at the inlet of both the turbines and the lubricant trapping unit. The active cha...

  18. Electrical studies on silver based fast ion conducting glassy materials

    International Nuclear Information System (INIS)

    Rao, B. Appa; Kumar, E. Ramesh; Kumari, K. Rajani; Bhikshamaiah, G.

    2014-01-01

    Among all the available fast ion conductors, silver based glasses exhibit high conductivity. Further, glasses containing silver iodide enhances fast ion conducting behavior at room temperature. Glasses of various compositions of silver based fast ion conductors in the AgI−Ag 2 O−[(1−x)B 2 O 3 −xTeO 2 ] (x=0 to1 mol% in steps of 0.2) glassy system have been prepared by melt quenching method. The glassy nature of the compounds has been confirmed by X-ray diffraction. The electrical conductivity (AC) measurements have been carried out in the frequency range of 1 KHz–3MHz by Impedance Analyzer in the temperature range 303–423K. The DC conductivity measurements were also carried out in the temperature range 300–523K. From both AC and DC conductivity studies, it is found that the conductivity increases and activation energy decreases with increasing the concentration of TeO 2 as well as with temperature. The conductivity of the present glass system is found to be of the order of 10 −2 S/cm at room temperature. The ionic transport number of these glasses is found to be 0.999 indicating that these glasses can be used as electrolyte in batteries

  19. Silicon-tin oxynitride glassy composition and use as anode for lithium-ion battery

    Science.gov (United States)

    Neudecker, Bernd J.; Bates, John B.

    2001-01-01

    Disclosed are silicon-tin oxynitride glassy compositions which are especially useful in the construction of anode material for thin-film electrochemical devices including rechargeable lithium-ion batteries, electrochromic mirrors, electrochromic windows, and actuators. Additional applications of silicon-tin oxynitride glassy compositions include optical fibers and optical waveguides.

  20. Evaluation of grapevine as a host for the glassy-winged sharpshooter

    Science.gov (United States)

    Grapevine was evaluated as a feeding and oviposition host for the glassy-winged sharpshooter. Two sets of experiments were conducted. The first set compared performance and preference of glassy-winged sharpshooter females for grapevine (cv. Chardonnay) versus cowpea (Vigna unguiculata cultivar black...

  1. Design and development of ITER high-frequency magnetic sensor

    Czech Academy of Sciences Publication Activity Database

    Ma, Y.; Vayakis, G.; Begrambekov, L.B.; Cooper, J.-J.; Ďuran, Ivan; Hirsch, M.; Laqua, H.P.; Moreau, P.; Oosterbeek, J.W.; Spuig, P.; Stange, T.; Walsh, M.

    2016-01-01

    Roč. 112, November (2016), s. 594-612 ISSN 0920-3796 Institutional support: RVO:61389021 Keywords : ITER * High-frequency * Magnetic diagnostics * ECHa Subject RIV: JF - Nuclear Energetics OBOR OECD: Nuclear related engineering Impact factor: 1.319, year: 2016

  2. Comparison of the voltammetric behavior of metronidazole at a DNA-modified glassy carbon electrode, a mercury thin film electrode and a glassy carbon electrode

    OpenAIRE

    Brett, Ana Maria Oliveira; Serrano, Silvia H. P.; Gutz, Ivano G. R.; La-Scalea, Mauro A.

    1997-01-01

    The electroanalytical performance at three electrodes: DNA-modified galssy carbon electrode, mercury thin film electrode and glassy carbon electrode, for the study of the electrochemical reduction of metronidazole is compared. All three electrodes showed a similar trend in the reduction mechanism for metronidazole, depenent on pH in the acid and neutral region and independent in alkaline media, although there was a shift in the peak potentials to more negative values when a bare glassy carbon...

  3. Radiation Storm vs. The Magnetic Shield: Superheroes of Magnetism & Space Weather Education - A Model for Teacher Professional Development Workshops

    Science.gov (United States)

    Russell, R. M.; Johnson, R. M.

    2010-12-01

    Magnetic and electric fields and phenomena play important roles in various situations in astronomy, planetary science, and Earth science. Students often lack an intuitive sense of electromagnetic phenomena, and therefore struggle with the complexities of planetary and stellar magnetic fields. Hands-on magnetism activities can provide students with an intuitive grasp of the basics of magnetism, preparing them for more challenging conceptual studies of magnetic phenomena. For the past six years, we have been presenting a professional development workshop for teachers covering the topics of magnetism and space weather. The workshop, which has been conducted more than 20 times for a range of audiences, blends together several simple hands-on activities, background information on space weather and geomagnetism, a collection of images, animations, and interactives that illustrate important concepts, and guidance about specific links between these topics and national science education standards. These workshops have been very well-received, and have consistently been rated highly by participants in surveys. We believe the methods used in these workshops can be applied to other topics in science education and to astronomy and Earth science education specifically. In this presentation, we will describe our magnetism and space weather workshop, including some of the hands-on activities. We will describe successful aspects of the workshop and comment on ways we think this approach could be replicated for other topics. We will also display some of the interactives, graphics, and animations shown during the workshops. Resources have been added to the workshop over the years in response to recurring questions from teachers; we will comment on this process and how it might be applied to other topics. The activities and extensive background content used or referenced in the workshop are available for free on the Windows to the Universe web site (www.windows2universe.org). Hands on

  4. Development of rapid detection system on BEPC Ⅱ magnet power supply

    International Nuclear Information System (INIS)

    Chen Suying; Zhan Mingchuan; Long Fengli; Ye Weidong

    2014-01-01

    To quickly find the causes of the accelerator unstable or lost beam caused by magnet power supply in Beijing Electron Positron Collider (BEPC Ⅱ) running, the rapid detection system for magnet power supply was developed. The stability of the system in 8 h is about 0.005%, and it can acquire over nearly 500 sets of magnet power supply current values most quickly in 0.33 ms. All data were written to the MySQL database in real time, so as to be able to quickly troubleshoot magnet power supply problem through historical data analysis and comparison. (authors)

  5. The effect of low temperature cryocoolers on the development of low temperature superconducting magnets

    International Nuclear Information System (INIS)

    Green, Michael A.

    2000-01-01

    The commercial development of reliable 4 K cryocoolers improves the future prospects for magnets made from low temperature superconductors (LTS). The hope of the developers of high temperature superconductors (HTS) has been to replace liquid helium cooled LTS magnets with HTS magnets that operate at or near liquid nitrogen temperature. There has been limited success in this endeavor, but continued problems with HTS conductors have greatly slowed progress toward this goal. The development of cryocoolers that reliably operate below 4 K will allow magnets made from LTS conductor to remain very competitive for many years to come. A key enabling technology for the use of low temperature cryocoolers on LTS magnets has been the development of HTS leads. This report describes the characteristics of LTS magnets that can be successfully melded to low-temperature cryocoolers. This report will also show when it is not appropriate to consider the use of low-temperature cryocoolers to cool magnets made with LTS conductor. A couple of specific examples of LTS magnets where cryocoolers can be used are given

  6. MAGNET

    CERN Multimedia

    B. Curé

    2011-01-01

    The magnet ran smoothly in the last few months until a fast dump occurred on 9th May 2011. Fortunately, this occurred in the afternoon of the first day of the technical stop. The fast dump was due to a valve position controller that caused the sudden closure of a valve. This valve is used to regulate the helium flow on one of the two current leads, which electrically connects the coil at 4.5 K to the busbars at room temperature. With no helium flow on the lead, the voltage drop and the temperatures across the leads increase up to the defined thresholds, triggering a fast dump through the Magnet Safety System (MSS). The automatic reaction triggered by the MSS worked properly. The helium release was limited as the pressure rise was just at the limit of the safety valve opening pressure. The average temperature of the magnet reached 72 K. It took four days to recover the temperature and refill the helium volumes. The faulty valve controller was replaced by a spare one before the magnet ramp-up resumed....

  7. Synthesis of One-Dimensional SiC Nanostructures from a Glassy Buckypaper

    Energy Technology Data Exchange (ETDEWEB)

    Ding, Mengning; Star, Alexander

    2013-02-21

    A simple and scalable synthetic strategy was developed for the fabrication of one-dimensional SiC nanostructures - nanorods and nanowires. Thin sheets of single-walled carbon nanotubes (SWNTs) were prepared by vacuum filtration and were washed repeatedly with sodium silicate (Na₂SiO₃) solution. The resulting “glassy buckypaper” was heated at 1300 - 1500 °C under Ar/H₂ to allow a solid state reaction between C and Si precursors to form a variety of SiC nanostructures. The morphology and crystal structures of SiC nanorods and nanowires were characterized using scanning electron microscopy (SEM), high-resolution transmission electron microscopy (HR-TEM), energy dispersive xray spectroscopy (EDX), electron diffraction (ED) and x-ray diffraction (XRD) techniques. Furthermore, electrical conductance measurements were performed on SiC nanorods, demonstrating their potential applications in high-temperature sensors and control systems.

  8. Voltammetric behavior of sedative drug midazolam at glassy carbon electrode in solubilized systems.

    Science.gov (United States)

    Jain, Rajeev; Yadav, Rajeev Kumar

    2012-04-01

    Redox behavior of midazolam was studied at a glassy carbon electrode in various buffer systems, supporting electrolytes and pH using differential pulse, square-wave and cyclic voltammetry. Based on its reduction behavior, a direct differential pulse voltammetric method has been developed and validated for the determination of midazolam in parenteral dosage. Three well-defined peaks were observed in 0.1% SLS, Britton-Robinson (BR) buffer of pH 2.5. The effect of surfactants like sodium lauryl sulfate (SLS), cetyl trimethyl ammonium bromide (CTAB) and Tween 20 was studied. Among these surfactants SLS showed significant enhancement in reduction peak. The cathodic peak currents were directly proportional to the concentration of midazolam with correlation coefficient of 0.99.

  9. Electrochemical Determination of Uric Acid at CdTe Quantum Dot Modified Glassy Carbon Electrodes.

    Science.gov (United States)

    Pan, Deng; Rong, Shengzhong; Zhang, Guangteng; Zhang, Yannan; Zhou, Qiang; Liu, Fenghai; Li, Miaojing; Chang, Dong; Pan, Hongzhi

    2015-01-01

    Cyclic voltammetry and differential pulse voltammetry were used to investigate the electrochemical behavior of uric acid (UA) at a CdTe quantum dot (QD) modified the glassy carbon electrode (GCE). CdTe QDs, as new semiconductor nanocrystals, can greatly improve the peak current of UA. The anodic peak current of UA was linear with its concentration between 1.0×10(-6) and 4.0×10(-4) M in 0.1 M pH 5.0 phosphate buffer solution. The LOD for UA at the CdTe electrode (1.0×10(-7) M) was superior to that of the GCE. In addition, we also determined the effects of scan rate, pH, and interferences of UA for the voltammetric behavior and detection. The results indicated that modified electrode possessed excellent reproducibility and stability. Finally, a new and efficient electrochemical sensor for detecting UA was developed.

  10. Polymer modified glassy carbon electrode for the electrochemical determination of caffeine in coffee.

    Science.gov (United States)

    Amare, Meareg; Admassie, Shimelis

    2012-05-15

    4-Amino-3-hydroxynaphthalene sulfonic acid (AHNSA) was electropolymerized on a glassy carbon electrode. The deposited film showed electrocatalytic activity towards the oxidation of caffeine. The polymer-modified electrode showed high sensitivity, selectivity and stability in the determination of caffeine in coffee. The peak current increased linearly with the concentration of caffeine in the range of 6 × 10(-8) to 4 × 10(-5) mol L(-1), with a detection limit of 1.37 × 10(-7) mol L(-1) (LoD = 3δ/slope). Analysis of caffeine in coffee was affected neither by sample matrices nor by structurally similar compounds. Recoveries ranging between 93.75 ± 2.32 and 100.75 ± 3.32 were achieved from coffee extracts indicating the applicability of the developed method for real sample analyses. Copyright © 2012 Elsevier B.V. All rights reserved.

  11. Study of electrochemical oxidation and determination of albendazole using a glassy carbon-rotating disk electrode.

    Science.gov (United States)

    Santos, André L; Takeuchi, Regina M; Mariotti, Marcela P; De Oliveira, Marcelo F; Zanoni, Maria V B; Stradiotto, Nelson R

    2005-08-01

    In this work, electrochemical oxidation of albendazole (ABZ) was carried out using a glassy carbon-rotating disk electrode. Development of electroanalytical methodology for ABZ quantification in pharmaceutical formulations was also proposed by using linear sweep voltammetric technique. Electrochemical oxidation is observed for ABZ at E(1/2)=0.99 V vs. Ag/AgCl(sat), when an anodic wave is observed. Kinetic parameters obtained for ABZ oxidation exhibited a standard heterogeneous rate constant for the electrodic process equal to (1.51+/-0.07) x 10(-5) cm s(-1), with a alphan(a) value equal to 0.76. Limiting current dependence against ABZ concentration exhibited linearity on 5.0 x 10(-5) to 1.0 x 10(-2) mol l(-1) range, being obtained a detection limit of 2.4 x 10(-5) mol l(-1). Proposed methodology was applied to ABZ quantification in pharmaceutical formulations.

  12. Voltammetric Determination of Flunixin on Molecularly Imprinted Polypyrrole Modified Glassy Carbon Electrode

    Directory of Open Access Journals (Sweden)

    Abd-Elgawad Radi

    2016-01-01

    Full Text Available A novel electrochemical sensing approach, based on electropolymerization of a molecularly imprinted polypyrrole (MIPpy film onto a glassy carbon electrode (GCE surface, was developed for the detection of flunixin (FXN. The sensing conditions and the performance of the constructed sensor were assessed by cyclic, differential pulse and (DPV square wave voltammetry (SWV. The sensor exhibited high sensitivity, with linear responses in the range of 5.0 to 50.0 µM with detection limits of 1.5 and 1.0 µM for DPV and SWV, respectively. In addition, the sensor showed high selectivity towards FXN in comparison to other interferents. The sensor was successfully utilized for the direct determination of FXN in buffalo raw milk samples.

  13. Electrochemical Determination of Glycoalkaloids Using a Carbon Nanotubes-Phenylboronic Acid Modified Glassy Carbon Electrode

    Directory of Open Access Journals (Sweden)

    Huiying Wang

    2013-11-01

    Full Text Available A versatile strategy for electrochemical determination of glycoalkaloids (GAs was developed by using a carbon nanotubes-phenylboronic acid (CNTs-PBA modified glassy carbon electrode. PBA reacts with α-solanine and α-chaconine to form a cyclic ester, which could be utilized to detect GAs. This method allowed GA detection from 1 μM to 28 μM and the detection limit was 0.3 μM. Affinity interaction of GAs and immobilized PBA caused an essential change of the peak current. The CNT-PBA modified electrodes were sensitive for detection of GAs, and the peak current values were in quite good agreement with those measured by the sensors.

  14. Axisymmetric magnetic mirrors for plasma confinement. Recent development and perspectives

    International Nuclear Information System (INIS)

    Kruglyakov, E.P.; Dimov, G.I.; Ivanov, A.A.; Koidan, V.S.

    2003-01-01

    Mirrors are the only one class of fusion systems which completely differs topologically from the systems with closed magnetic configurations. At present, three modern types of different mirror machines for plasma confinement and heating exist in Novosibirsk (Gas Dynamic Trap,- GDT, Multi-mirror,- GOL-3, and Tandem Mirror,- AMBAL-M). All these systems are attractive from the engineering point of view because of very simple axisymmetric geometry of magnetic configurations. In the present paper, the status of different confinement systems is presented. The experiments most crucial for the mirror concept are described such as a demonstration of different principles of suppression of electron heat conductivity (GDT, GOL-3), finding of MHD stable regimes of plasma confinement in axisymmetric geometry of magnetic field (GDT, AMBAL-M), an effective heating of a dense plasma by relativistic electron beam (GOL-3), observation of radial diffusion of quiescent plasma with practically classical diffusion coefficient (AMBAL-M), etc. It should be mentioned that on the basis of the GDT it is possible to make a very important intermediate step. Using 'warm' plasma and oblique injection of fast atoms of D and T one can create a powerful 14 MeV neutron source with a moderate irradiation area (about 1 square meter) and, accordingly, with low tritium consumption. The main plasma parameters achieved are presented and the future perspectives of different mirror machines are outlined. (author)

  15. Program for development of high-field superconducting magnets for fusion research

    International Nuclear Information System (INIS)

    1975-01-01

    Three superconducting magnet programs at LLL are outlined. The first program, the one considered in greatest detail, is a developmental program in which LLL will work closely with superconductor manufacturers to develop multifilamentary Nb 3 Sn superconductor suitable for use in large CTR magnets. The result of this program will be the fabrication of a rather large magnet (but one that is much smaller than future CTR magnets) and the determination of its performance limitations. In the second program, the developed multifilamentary Nb 3 Sn superconductor will be used to construct the magnets for the Fusion Engineering Research Facility (FERF) machine. In this program, the bulk of the effort will be in magnet design and winding. The third program chronologically overlaps the first two programs. This program includes the fabrication and testing of the superconducting magnets for the MX machine although, as explained in the Technical Plan, only the cost of the development work is included in this document. At the present time, Nb--Ti superconductor is being considered. Apart from some initial conductor design work, the major effort will be in magnet design and winding

  16. Development of high field magnets at the National Research Institute for Metals. Kinzoku zairyo gijutsu kenkyusho ni okeru kojikai magnet gun no kaihatsu

    Energy Technology Data Exchange (ETDEWEB)

    Kiyoshi, T.; Inoue, K.; Maeda, H. (National Research Inst. for Metals, Tsukuba (Japan))

    1993-06-20

    Sinece 1988, the Scince and Technology Agency has initiated the superconductor multicore project, which has a purpose of the versatile study on the high temperature superconducting materials of the oxide series. The National Research Institute for Metals is in charge of 5 cores out of them, and in the performance evaluation core which is one of them, the development of each kind of the high field magnets is being advanced for evaluating the characteristics under the high magnetic field. As the magnets, including the 40T class hybrid magnet which generates the steady state magnetic field of 40T, the superconducting magnet of 20T with a large diameter which generates the magnetic field over 20T with a superconductor, the condenser bank system for the pulse magnet to generate the pulse magnetic field up to 80T, and the ultra-precise magnet system which generates the magnetic field with a high uniformity will be consolidated. Keeping pace with a removal of the National Research Institute for Metals to Tsukuba, the construction of the strong magnetic field station is being advanced in the Sakura area. These several kinds of magnets are scheduled to be used in turn for the international joint study. 33 refs., 5 figs., 4 tabs.

  17. Development of Magnetically Driven Swimming Micro-robot for Science Education

    Science.gov (United States)

    Eiki, Takashi; Honda, Takashi; Yamasaki, Jiro

    A dolphin-type swimming micro-robot has been developed for science education. This micro-robot, approximately 60mm in length, consists of a rigid body balanced with a float, and a propulsive mechanism including a magnet and an elastic fin. The mechanism features unique design based on biomimetics and a simple structure for easy construction. When external alternating magnetic fields are applied, the magnet oscillates angularly due to magnetic torque and then the caudal fin can produce a thrust. The micro-robot can swim at over 30cm/sec under alternating magnetic fields of 4kA/m at 20Hz. Results of a handicraft class at an elementary school have demonstrated that the micro-robot developed in this study is useful for science education.

  18. MAGNET

    CERN Multimedia

    Benoit Curé

    2010-01-01

    The magnet worked very well at 3.8 T as expected, despite a technical issue that manifested twice in the cryogenics since June. All the other magnet sub-systems worked without flaw. The issue in the cryogenics was with the cold box: it could be observed that the cold box was getting progressively blocked, due to some residual humidity and air accumulating in the first thermal exchanger and in the adsorber at 65 K. This was later confirmed by the analysis during the regeneration phases. An increase in the temperature difference between the helium inlet and outlet across the heat exchanger and a pressure drop increase on the filter of the adsorber were observed. The consequence was a reduction of the helium flow, first compensated by the automatic opening of the regulation valves. But once they were fully opened, the flow and refrigeration power reduced as a consequence. In such a situation, the liquid helium level in the helium Dewar decreased, eventually causing a ramp down of the magnet current and a field...

  19. MAGNET

    CERN Multimedia

    B. Curé

    MAGNET During the winter shutdown, the magnet subsystems went through a full maintenance. The magnet was successfully warmed up to room temperature beginning of December 2008. The vacuum was broken later on by injecting nitrogen at a pressure just above one atmosphere inside the vacuum tank. This was necessary both to prevent any accidental humidity ingress, and to allow for a modification of the vacuum gauges on the vacuum tank and maintenance of the diffusion pumps. The vacuum gauges had to be changed, because of erratic variations on the measurements, causing spurious alarms. The new type of vacuum gauges has been used in similar conditions on the other LHC experiments and without problems. They are shielded against the stray field. The lubricants of the primary and diffusion pumps have been changed. Several minor modifications were also carried out on the equipment in the service cavern, with the aim to ease the maintenance and to allow possible intervention during operation. Spare sensors have been bough...

  20. MAGNET

    CERN Multimedia

    B. Curé

    2013-01-01

    The magnet is fully stopped and at room temperature. The maintenance works and consolidation activities on the magnet sub-systems are progressing. To consolidate the cryogenic installation, two redundant helium compressors will be installed as ‘hot spares’, to avoid the risk of a magnet downtime in case of a major failure of a compressor unit during operation. The screw compressors, their motors, the mechanical couplings and the concrete blocks are already available and stored at P5. The metallic structure used to access the existing compressors in SH5 will be modified to allow the installation of the two redundant ones. The plan is to finish the installation and commissioning of the hot spare compressors before the summer 2014. In the meantime, a bypass on the high-pressure helium piping will be installed for the connection of a helium drier unit later during the Long Shutdown 1, keeping this installation out of the schedule critical path. A proposal is now being prepared for the con...

  1. MAGNET

    CERN Multimedia

    Benoit Curé.

    The magnet operation restarted end of June this year. Quick routine checks of the magnet sub-systems were performed at low current before starting the ramps up to higher field. It appeared clearly that the end of the field ramp down to zero was too long to be compatible with the detector commissioning and operations plans. It was decided to perform an upgrade to keep the ramp down from 3.8T to zero within 4 hours. On July 10th, when a field of 1.5T was reached, small movements were observed in the forward region support table and it was decided to fix this problem before going to higher field. At the end of July the ramps could be resumed. On July 28th, the field was at 3.8T and the summer CRAFT exercise could start. This run in August went smoothly until a general CERN wide power cut took place on August 3rd, due to an insulation fault on the high voltage network outside point 5. It affected the magnet powering electrical circuit, as it caused the opening of the main circuit breakers, resulting in a fast du...

  2. Development of an Anti-Vibration Controller for Magnetic Bearing Cooling Systems Project

    Data.gov (United States)

    National Aeronautics and Space Administration — This proposal outlines a program to develop a vibration-free reverse-Brayton cycle cooling system using specially-tuned magnetic bearings. Such a system is critical...

  3. Anatomical Brain Magnetic Resonance Imaging of Typically Developing Children and Adolescents

    Science.gov (United States)

    Giedd, Jay N.; Lalonde, Francois M.; Celano, Mark J.; White, Samantha L.; Wallace, Gregory L.; Lee, Nancy R.; Lenroot, Rhoshel K.

    2009-01-01

    Methodological issues relevant to magnetic resonance imaging studies of brain anatomy are discussed along with the findings on the neuroanatomic changes during childhood and adolescence. The development of the brain is also discussed.

  4. Development of an Anti-Vibration Controller for Magnetic Bearing Cooling Systems, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — This proposal outlines a program to develop a vibration-free reverse-Brayton cycle cooling system using specially-tuned magnetic bearings. Such a system is critical...

  5. Structural and spectroscopic studies of a commercial glassy carbon

    Science.gov (United States)

    Parker, Stewart F.; Imberti, Silvia; Callear, Samantha K.; Albers, Peter W.

    2013-12-01

    Glassy carbon is a form of carbon made by heating a phenolic resin to high temperature in an inert atmosphere. It has been suggested that it is composed of fullerene-like structures. The aim of the present work was to characterize the material using both structural (neutron diffraction and transmission electron microscopy) and spectroscopic (inelastic neutron scattering, Raman and X-ray photoelectron spectroscopies) methods. We find no evidence to support the suggestion of fullerene-like material being present to a significant extent, rather the model that emerges from all of the techniques is that the material is very like amorphous carbon, consisting of regions of small graphite-like basic structural units of partly stacked but mismatched structure with the edges terminated by hydrogen or hydroxyls. We do find evidence for the presence of a small quantity of water trapped in the network and suggest that this may account for batch-to-batch variation in properties that may occur.

  6. Glassy behavior and dynamic tweed in defect-free multiferroics

    Science.gov (United States)

    Wang, Xiaofei; Salje, Ekhard K. H.; Sun, Jun; Ding, Xiangdong

    2018-01-01

    Multiferroics often show significant elastic fluctuations even when the transition is strongly stepwise. Molecular dynamics simulations of a generic toy model show the appearance of tweed nanostructures (cross hatched patterns) in the paraelastic phase just above the transition point. This tweed lowers the elastic modulus C12 when approaching the transition temperature. The spatial and temporal correlations of the tweed structure follow the Vogel-Fulcher relationship, and the Vogel-Fulcher temperature is slightly below the transition temperature Ttrans, preventing this glassy state to freeze completely. Spatial correlations of shear strain show that the size of tweed patches reaches about eight lattice spacings near Ttrans. Cross- and rod-shaped diffuse scattering, similar to that in relaxors, emerges around {hh0}* and {h00}* Bragg reflections. The viscosity of the sample increases dramatically at the transition point with a significant precursor increase in the tweed regime.

  7. Glassy dynamics and heterogeneity of polymer thin films

    International Nuclear Information System (INIS)

    Kanaya, Toshiji; Inoue, Rintaro; Kawashima, Kazuko; Miyazaki, Tsukasa; Matsuba, Go; Nishida, Koji; Tsukushi, Itaru; Shibata, Kaoru; Hino, Masahiro

    2009-01-01

    We review our recent studies on glassy dynamics and glass transition of polymer thin films using neutron and X-ray reflectivity and inelastic neutron techniques. In the last decade extensive studies have been performed on polymer thin films to reveal very interesting but unusual properties such as reduction in the glass transition temperature T g with film thickness and negative thermal expansivity for thin films below about 25 nm, and often some contradictory experimental results have been reported. It is believed that a key to solve the controversial situation is to disclose heterogeneous structure or multi-layer structure in polymer thin films. In the review, therefore, we summarize our recent experimental results by neutron and X-ray reflectivity and inelastic neutron scattering, focusing on the dynamic heterogeneity in polymer thin films. (author)

  8. The Glassy Phase of Complex Branching Brownian Motion

    Science.gov (United States)

    Madaule, Thomas; Rhodes, Rémi; Vargas, Vincent

    2015-03-01

    In this paper, we study complex valued branching Brownian motion in the so-called glassy phase, also called phase II. In this context, we prove a limit theorem for the complex partition function hence confirming a conjecture formulated by Lacoin and the last two authors in a previous paper on complex Gaussian multiplicative chaos. We will show that the limiting partition function can be expressed as a product of a Gaussian random variable, mainly due to the windings of the phase, and a stable transform of the so-called derivative martingale, mainly due to the clustering of the modulus. The proof relies on the fine description of the extremal process available in the branching Brownian motion context.

  9. In situ nanocalorimetry of thin glassy organic films

    Science.gov (United States)

    León-Gutierrez, E.; Garcia, G.; Lopeandía, A. F.; Fraxedas, J.; Clavaguera-Mora, M. T.; Rodríguez-Viejo, J.

    2008-11-01

    In this work, we describe the design and first experimental results of a new setup that combines evaporation of liquids in ultrahigh vacuum conditions with in situ high sensitivity thermal characterization of thin films. Organic compounds are deposited from the vapor directly onto a liquid nitrogen cooled substrate, permitting the preparation and characterization of glassy films. The substrate consists of a microfabricated, membrane-based nanocalorimeter that permits in situ measurements of heat capacity under ultrafast heating rates (up to 105 K/s) in the temperature range of 100-300 K. Three glass forming liquids—toluene, methanol, and acetic acid—are characterized. The spikes in heat capacity related to the glass-transition temperature, the fictive temperature and, in some cases, the onset temperature of crystallization are determined for several heating rates.

  10. Mechanical Properties for Reliability Analysis of Structures in Glassy Carbon

    CERN Document Server

    Garion, Cédric

    2014-01-01

    Despite its good physical properties, the glassy carbon material is not widely used, especially for structural applications. Nevertheless, its transparency to particles and temperature resistance are interesting properties for the applications to vacuum chambers and components in high energy physics. For example, it has been proposed for fast shutter valve in particle accelerator [1] [2]. The mechanical properties have to be carefully determined to assess the reliability of structures in such a material. In this paper, mechanical tests have been carried out to determine the elastic parameters, the strength and toughness on commercial grades. A statistical approach, based on the Weibull’s distribution, is used to characterize the material both in tension and compression. The results are compared to the literature and the difference of properties for these two loading cases is shown. Based on a Finite Element analysis, a statistical approach is applied to define the reliability of a structural component in gl...

  11. Development of magnetic fabric in sedimentary rocks: Insights from early compactional structures

    OpenAIRE

    García-Lasanta, C; Oliva-Urcia, Belén; Román-Berdiel, T.; Casas, A. M.; Pérez-Lorente, F.

    2013-01-01

    The timing of development of the magnetic fabric is a major issue in the application of anisotropy of magnetic susceptibility (AMS) as a strain marker. Analysis of AMS in unconcealed synsedimentary structures can be a sound approximation to this task. In this work, three types of early compactional structures (ECS) were studied by means of AMS, since they can help to understand the timing of development of the magnetic fabric. All three types of ECS are found in fine-grained detrital rocks (t...

  12. Development of electromagnetic wave absorbers with alnico magnets

    International Nuclear Information System (INIS)

    Song, Jae Man; Kim, Dong Il; Shin, Seung Jae; Moon, Sang Hyun; Kim, Ki Man; Rhyu, Keel Soo

    2004-01-01

    We suggest a cast Alnico magnet as a new EM wave absorber. The proposed Alnico EM wave absorber shows advanced EM wave absorption properties of 24 dB at 15 GHz, 24 dB at 8.1 GHz, and 24 dB at 5.1 GHz for thicknesses of 1 mm, 2 mm, and 3 mm respectively. We also investigated the effects of the carbon and the Alnico contents and of the thickness dependence on the EM wave absorption properties.

  13. 18T resistive magnet development. Conceptual design second annual report

    Energy Technology Data Exchange (ETDEWEB)

    Agarwal, K.L.; Burgeson, J.E.; Gurol, H.; Mancuso, A.; Michels, P.H.

    1985-10-01

    This report documents the work performed on a normal conducting magnet during fiscal year 1985. Emphasis, during the study, was on refinement of the structural design and optimization of the coil current density distribution for either maximum field generation or minimum power consumption. The results have shown that one can generate a 4.4 tesla field using 6.14 megawatts or 3.1 tesla at 1.43 megawatts. The structural design has been modified to stiffen the outer turn of the conductor. The modification was confirmed to be structurally adequate by both analysis and test. 37 figs., 21 tabs.

  14. Compostos magnéticos moleculares: o desenvolvimento de novos materiais magnéticos nanoestruturados Molecular magnetic compounds: the development of new nanostrutured magnetic materials

    Directory of Open Access Journals (Sweden)

    Guilherme P. Guedes

    2010-01-01

    Full Text Available The development of new magnetic materials has attracted attention of researchers of different areas. In the last decades, a distinguished class of materials emerged in magnetism, in which the magnetic moment is delocalized over molecules. By varying the synthetic conditions it is possible to obtain a large variety of structures and properties using the same starting molecules. These materials have a great scientific appeal due to the possibility of presenting not only magnetic, but also optical or electrical transport properties. In this review we will present an overview of some molecular magnetic compounds, in particular molecular nanomagnets.

  15. Multilevel micro-structuring of glassy carbon molds for precision glass molding

    Science.gov (United States)

    Prater, Karin; Dukwen, Julia; Scharf, Toralf; Herzig, Hans Peter; Plöger, Sven; Hermerschmidt, Andreas

    2015-09-01

    Replication techniques for diffractive optical elements (DOEs) in soft materials such as plastic injection molding are state of the art. For precision glass molding in glasses with high transition temperatures, molds with extreme thermal resistivity, low chemical reactivity and high mechanical strength are needed. Glassy Carbon can be operated up to 2000°C making it possible to mold almost all glasses including Fused Silica with a transition temperatures above 1060°C. For the structuring of Glassy Carbon wafers photolithography and a RIE process is used. We have developed a process using Si as a hard mask material. If the flow rates of the etching gases O2 and SF6 are chosen properly, high selectivity of GC to Si 19:1 can be achieved, which provides excellent conditions to realize high resolution elements with feature size down to 1 micron and fulfills requirements for optical applications. We fabricated several multilevel GC molds with 8 levels of structuring. Two different optical functionalities were implemented: 6x6 array beamsplitter and 1x4 linear beamsplitter. The molds were applied for precision glass molding of a low Tg glass L-BAL 42 (from Ohara) with a transition temperature of 565°C. Their optical performance was measured. A more detailed analysis of the impact of mold fabrication defects on optical performance is done. Rigorous coupled wave analysis simulations are performed, where we included fabrication constrains such as duty cycle, edge depth errors, wall verticality and misalignment errors. We will compare the results with the design specifications and discuss the influence of fabrication errors introduced during the different process steps.

  16. Design and development of ITER high-frequency magnetic sensor

    Energy Technology Data Exchange (ETDEWEB)

    Ma, Y., E-mail: Yunxing.Ma@iter.org [ITER Organization, Route de Vinon-sur-Verdon, CS 90 046, 13067 St. Paul Lez Durance Cedex (France); Fircroft Engineering, Lingley House, 120 Birchwood Point, Birchwood Boulevard, Warrington, WA3 7QH (United Kingdom); Vayakis, G. [ITER Organization, Route de Vinon-sur-Verdon, CS 90 046, 13067 St. Paul Lez Durance Cedex (France); Begrambekov, L.B. [National Research Nuclear University (MEPhI), 115409, Moscow, Kashirskoe shosse 31 (Russian Federation); Cooper, J.-J. [Culham Centre for Fusion Energy (CCFE), Abingdon, Oxfordshire OX14 3DB (United Kingdom); Duran, I. [IPP Prague, Za Slovankou 1782/3, 182 00 Prague 8 (Czech Republic); Hirsch, M.; Laqua, H.P. [Max-Planck-Institut für Plasmaphysik, Teilinstitut Greifswald, Wendelsteinstraße 1, D-17491 Greifswald (Germany); Moreau, Ph. [CEA Cadarache, 13108 Saint Paul lez Durance Cedex (France); Oosterbeek, J.W. [Eindhoven University of Technology (TU/e), PO Box 513, 5600 MB Eindhoven (Netherlands); Spuig, P. [CEA Cadarache, 13108 Saint Paul lez Durance Cedex (France); Stange, T. [Max-Planck-Institut für Plasmaphysik, Teilinstitut Greifswald, Wendelsteinstraße 1, D-17491 Greifswald (Germany); Walsh, M. [ITER Organization, Route de Vinon-sur-Verdon, CS 90 046, 13067 St. Paul Lez Durance Cedex (France)

    2016-11-15

    Highlights: • ITER high-frequency magnetic sensor system has been designed. • Prototypes have been successfully manufactured. • Manufactured prototypes have been tested in various labs. • Test results experimentally validated the design. - Abstract: High-frequency (HF) inductive magnetic sensors are the primary ITER diagnostic set for Toroidal Alfvén Eigenmodes (TAE) detection, while they also supplement low-frequency MHD and plasma equilibrium measurements. These sensors will be installed on the inner surface of ITER vacuum vessel, operated in a harsh environment with considerable neutron/nuclear radiation and high thermal load. Essential components of the HF sensor system, including inductive coil, electron cyclotron heating (ECH) shield, electrical cabling and termination load, have been designed to meet ITER measurement requirements. System performance (e.g. frequency response, thermal conduction) has been assessed. A prototyping campaign was initiated to demonstrate the manufacturability of the designed components. Prototypes have been produced according to the specifications. A series of lab tests have been performed to examine assembly issues and validate electrical and thermo-mechanical aspects of the design. In-situ microwave radiation test has been conducted in the MISTRAL test facility at IPP-Greifswald to experimentally examine the microwave shielding efficiency and structural integrity of the ECH shield. Low-power microwave attenuation measurement and scanning electron microscopic inspection were conducted to probe and examine the quality of the metal coating on the ECH shield.

  17. Magnetic fusion energy and computers: the role of computing in magnetic fusion energy research and development

    International Nuclear Information System (INIS)

    This report examines the role of computing in the Department of Energy magnetic confinement fusion program. The present status of the MFECC and its associated network is described. The third part of this report examines the role of computer models in the main elements of the fusion program and discusses their dependence on the most advanced scientific computers. A review of requirements at the National MFE Computer Center was conducted in the spring of 1976. The results of this review led to the procurement of the CRAY 1, the most advanced scientific computer available, in the spring of 1978. The utilization of this computer in the MFE program has been very successful and is also described in the third part of the report. A new study of computer requirements for the MFE program was conducted during the spring of 1979 and the results of this analysis are presented in the forth part of this report

  18. Magnetic fusion energy and computers: the role of computing in magnetic fusion energy research and development

    Energy Technology Data Exchange (ETDEWEB)

    1979-10-01

    This report examines the role of computing in the Department of Energy magnetic confinement fusion program. The present status of the MFECC and its associated network is described. The third part of this report examines the role of computer models in the main elements of the fusion program and discusses their dependence on the most advanced scientific computers. A review of requirements at the National MFE Computer Center was conducted in the spring of 1976. The results of this review led to the procurement of the CRAY 1, the most advanced scientific computer available, in the spring of 1978. The utilization of this computer in the MFE program has been very successful and is also described in the third part of the report. A new study of computer requirements for the MFE program was conducted during the spring of 1979 and the results of this analysis are presented in the forth part of this report.

  19. Probing Stress-Induced Optical Birefringence of Glassy Polymers by Whispering Gallery Modes Light Localization.

    Science.gov (United States)

    Milenko, Karolina; Pissadakis, Stavros; Gkantzounis, Georgios; Aluculesei, Alina; Fytas, George

    2017-12-31

    An optical resonance method for the determination of the strain- and stress-optical coefficients of optically transparent polymers is presented and exemplified for monodisperse and bidisperse molecular weight polystyrene (PS). This method employs whispering gallery modes (WGMs) resonation inside a spheroid polymeric cavity, suspended on an optical fiber taper waist, which, in turn, is used for subjecting the polymeric resonator to controlled strain conditions. The wavelength shifts of equal order transverse electric and transverse magnetic polarization WGMs are measured, as well as their relative birefringence versus applied strain. For monodisperse PS microspheroids (2 and 50 kDa) the stress-optical coefficient is negative, contrary to the results for bulk PS in the glassy state indicating different phenyl group orientation of the PS monomer with respect to the strain direction. In the bidisperse (2 and 50 kDa) spheroid with a symmetric monomer composition, local structural irregularities are probably responsible for the observed coupling between WGMs. The method possesses metrological capabilities for probing the molecular orientation of polymer-based resonators.

  20. A conceptual magnetic fabric development model for the Paks loess in Hungary

    DEFF Research Database (Denmark)

    Bradák, B.; Ujvari, Gabor; Seto, Y.

    2018-01-01

    We describe magnetic fabric and depositional environments of aeolian (loess) deposits from Paks, Hungary, and develop a novel, complex conceptual sedimentation model based on grain size and low-field magnetic susceptibility anisotropy data. A plot of shape factor (magnetic fabric parameter) and dry...... deposition velocity estimated from grain-size reveals primary and secondary depositional processes during the sedimentation of loess. Primary ones are driven by gravity, with poorly oriented MF for fine grain materials, and by tangential stress, with flow-aligned or flow-transverse fabric for coarser grain...... sediments. The fabric developed by a primary process is called depositional magnetic fabric. Secondary processes develop in unconsolidated sediments, beginning right after deposition and terminating before the start of diagenesis. Under slow sedimentation conditions, deposited materials are likely...

  1. Design constraints on magnet systems of future tokamaks based on experiences of present s.c. magnet development

    International Nuclear Information System (INIS)

    Heinz, W.; Jeske, U.; Komarek, P.; Krauth, H.

    1983-01-01

    In view of the urgent need for superconductivity in the next generation of big fusion devices and the identified gap between aimed data and the state of the art, impressive development programs are running world-wide, e.g. the IEA-Large Coil Task (LCT) and magnets for near term experiments (T15, Tore Supra). During the development work for all these magnet systems and simultaneously running design studies, especially the INTOR-study, some critical problem areas, e.g. concerning NbTi-conductor design and manufacturing and coil fabrication could be solved, others like the limitations by fatigue stresses for coil case and support structure turned out to be more stringent than anticipated. This paper tries to show which plasma physics parameters place especially severe constraints to magnet design, like PF-pulse number and amplitude at the TF-coils, so that they should be chosen with strongest care. It further points out which technologies under these circumstances are still missing or unproven with respect to the INTOR-like generation of fusion experiments. Further effort is mainly required for fatigue load behaviour of materials and components, high field windings and poloidal field coils. (author)

  2. Exploring Ultrahigh Magnetic Field Processing of Materials for Developing Customized Microstructures and Enhanced Performance

    Energy Technology Data Exchange (ETDEWEB)

    Ludtka, GERALD M.

    2005-03-31

    Thermodynamic calculations based on Gibbs free energy in the magnetization-magnetic intensity-temperature (M-H-T) magnetic equation of state space demonstrate that significantly different phase equilibria may result for those material systems where the product and parent phases exhibit different magnetization responses. These calculations show that the Gibbs free energy is changed by a factor equal to -MdH, where M and H are the magnetization and applied field strength, respectively. Magnetic field processing is directly applicable to a multitude of alloys and compounds for dramatically influencing phase stability and phase transformations. This ability to selectively control microstructural stability and alter transformation kinetics through appropriate selection of the magnetic field strength promises to provide a very robust mechanism for developing and tailoring enhanced microstructures (and even nanostructures through accelerated kinetics) with superior properties for a broad spectrum of material applications. For this Industrial Materials for the Future (IMF) Advanced Materials for the Future project, ferrous alloys were studied initially since this alloy family exhibits ferromagnetism over part of its temperature range of stability and therefore would demonstrate the maximum impact of this novel processing mechanism. Additionally, with these ferrous alloys, the high-temperature parent phase, austenite, exhibits a significantly different magnetization response from the potential product phases, ferrite plus carbide or martensite; and therefore, the solid-state transformation behavior of these alloys will be dramatically influenced by the presence of ultrahigh magnetic fields. Finally, a thermodynamic calculation capability (within ThermoCalc for example) was developed during this project to enable parametric studies to be performed to predict the magnitude of the influence of magnetic processing variables on the phase stability (phase diagrams) in

  3. MAGNET

    CERN Multimedia

    Benoit Curé

    The magnet subsystems resumed operation early this spring. The vacuum pumping was restarted mid March, and the cryogenic power plant was restarted on March 30th. Three and a half weeks later, the magnet was at 4.5 K. The vacuum pumping system is performing well. One of the newly installed vacuum gauges had to be replaced at the end of the cool-down phase, as the values indicated were not coherent with the other pressure measurements. The correction had to be implemented quickly to be sure no helium leak could be at the origin of this anomaly. The pressure measurements have been stable and coherent since the change. The cryogenics worked well, and the cool-down went quite smoothly, without any particular difficulty. The automated start of the turbines had to be fine-tuned to get a smooth transition, as it was observed that the cooling power delivered by the turbines was slightly higher than needed, causing the cold box to stop automatically. This had no consequence as the cold box safety system acts to keep ...

  4. MAGNET

    CERN Multimedia

    B. Curé

    During the winter shutdown, the magnet subsystems went through a full maintenance. The magnet was successfully warmed up to room temperature beginning of December 2008. The vacuum was broken later on by injecting nitrogen at a pressure just above one atmosphere inside the vacuum tank. This was necessary both to prevent any accidental humidity ingress, and to allow for a modification of the vacuum gauges on the vacuum tank and maintenance of the diffusion pumps. The vacuum gauges had to be changed, because of erratic variations on the measurements, causing spurious alarms. The new type of vacuum gauges has been used in similar conditions on the other LHC experiments and without problems. They are shielded against the stray field. The lubricants of the primary and diffusion pumps have been changed. Several minor modifications were also carried out on the equipment in the service cavern, with the aim to ease the maintenance and to allow possible intervention during operation. Spare sensors have been bought. Th...

  5. Nb3Sn conductor development for the ITER magnets

    International Nuclear Information System (INIS)

    Mitchell, N.

    1997-01-01

    The ITER magnet system consists of Toroidal Field (TF) coils, Poloidal Field (PF) coils, the Central Solenoid (CS) and error field correction coils (CC). The conductors for the coils are Nb 3 Sn or NbTi cable in conduit type, forced flow cooled with supercritical helium having a maximum operating current in the range 40-60 kA. To qualify the Nb 3 Sn conductor, two large model coils (energy up to 640 MJ) are being wound by the Home Teams of the Parties to the ITER EDA Agreement. A total of 24 t of strand has been completed for the CS model coil and 4 t for the TF model coil, and fabricated into 7 km of conductor in unit lengths up to 210 m, by an international collaboration involving 12 companies in Europe, Japan, Russia and the USA

  6. Development and Testing of a Magnetically Actuated Capsule Endoscopy for Obesity Treatment.

    Directory of Open Access Journals (Sweden)

    Thanh Nho Do

    Full Text Available Intra-gastric balloons (IGB have become an efficient and less invasive method for obesity treatment. The use of traditional IGBs require complex insertion tools and flexible endoscopes to place and remove the balloon inside the patient's stomach, which may cause discomfort and complications to the patient. This paper introduces a new ingestible weight-loss capsule with a magnetically remote-controlled inflatable and deflatable balloon. To inflate the balloon, biocompatible effervescent chemicals are used. As the source of the actuation is provided via external magnetic fields, the magnetic capsule size can be significantly reduced compared to current weight-loss capsules in the literature. In addition, there are no limitations on the power supply. To lose weight, the obese subject needs only to swallow the magnetic capsule with a glass of water. Once the magnetic capsule has reached the patient's stomach, the balloon will be wirelessly inflated to occupy gastric space and give the feeling of satiety. The balloon can be wirelessly deflated at any time to allow the magnetic capsule to travel down the intestine and exit the body via normal peristalsis. The optimal ratio between the acid and base to provide the desired gas volume is experimentally evaluated and presented. A prototype capsule (9.6mm x 27mm is developed and experimentally validated in ex-vivo experiments. The unique ease of delivery and expulsion of the proposed magnetic capsule is slated to make this development a good treatment option for people seeking to lose excess weight.

  7. Local atomic and electronic structure in glassy metallic alloys. Final report, March 1, 1979-May 31, 1982

    International Nuclear Information System (INIS)

    Messmer, R.P.; Wong, J.

    1982-01-01

    The research results reported, represent the first coordinated experimental-theoretical effort to arrive at important local atomic and electronic structure information in glassy alloys. During the three years covered by the contract, significant experimental and theoretical developments have taken place both in the general technical community and at General Electric which have had an important impact on the approach to this problem. This is particularly true in the theoretical area where two important advances, the development of a general Xα-LCAO approach, and the development of a general and accurate effective potential approach for density functional methods, have allowed us to construct a new computational capability which combines these two advances. Two subsections briefly review the experimental and theoretical technical developments, respectively. These developments have changed initial perspectives regarding research on local atomic and electronic structure in glassy metallic alloys. Section II presents a synopsis of our accomplishments during the contract period and Section III contains a more detailed discussion of some of these accomplishments, namely those portions of the work which have been published or submitted for publication at the time of writing this final report

  8. Development of large high current density superconducting solenoid magnets for use in high energy physics experiments

    International Nuclear Information System (INIS)

    Green, M.A.

    1977-05-01

    The development of a unique type of large superconducting solenoid magnet, characterized by very high current density windings and a two-phase helium tubular cooling system is described. The development of the magnet's conceptual design and the construction of two test solenoids are described. The successful test of the superconducting coil and its tubular cooling refrigeration system is presented. The safety, environmental and economic impacts of the test program on future developments in high energy physics are shown. Large solid angle particle detectors for colliding beam physics will analyze both charged and neutral particles. In many cases, these detectors will require neutral particles, such as gamma rays, to pass through the magnet coil with minimum interaction. The magnet coils must be as thin as possible. The use of superconducting windings allows one to minimize radiation thickness, while at the same time maximizing charged particle momentum resolution and saving substantial quantities of electrical energy. The results of the experimental measurements show that large high current density solenoid magnets can be made to operate at high stored energies. The superconducting magnet development described has a positive safety and environmental impact. The use of large high current density thin superconducting solenoids has been proposed in two high energy physics experiments to be conducted at the Stanford Linear Accelerator Center and Cornell University as a result of the successful experiments described

  9. Effects of Magnetized Saline on Growth and Development of Winter Wheat Seedlings

    OpenAIRE

    Dandan LIU; Yan SHI

    2013-01-01

    In order to explore the effects of magnetized saline solution treatment on crop growth and development, with Jimai 22 as experimental material, this experiment studied the effects of magnetized water solution of 0.3% NaCl and 0.5% NaCl, groundwater solution of 0.3% NaCl and 0.5% NaCl on SPAD value, soluble protein content and activities of Superoxide Dismutase (SOD) and Catalase (CAT) of winter wheat. The results showed that, under the conditions of this experiment, the wheat of the magnetize...

  10. Developing a high-temperature superconducting bulk magnet for the maglev train of the future

    Science.gov (United States)

    Fujimoto, Hiroyuki

    1998-10-01

    The major applications of high-temperature superconductors have mostly been confined to products in the form of wires and thin films. However, recent developments show that rare-earth REBa2Cu3O7-x and light rare-earth LREBa2Cu3O7-3 superconductors prepared by melt processes have a high critical-current density at 77 K and high magnetic fields. These superconductors will promote the application of bulk high-temperature superconductors in high magnetic fields; the superconducting bulk magnet for the Maglev train is one possible application.

  11. Nd-Fe-B-Cu hot deformation processing: a comparison of deformation modes, microstructural development and magnetic properties

    International Nuclear Information System (INIS)

    Ferrante, M.; Sinka, V.; Assis, O.B.G.; Oliveira, I. de; Freitas, E. de

    1996-01-01

    Due to its relative simplicity and low cost the hot deformation of Nd-Fe-B ingots is rapidly reaching the status of a valid alternative to sintering. Among the possible deformation modes, pressing, rolling and forging are perhaps the most successful. This paper describes the research programme undertaken so far, by discussing the relationship between deformation mode, microstructure and magnetic properties of magnets produced by hot deformation mode, microstructure and magnetic properties of magnets produced by hot deformation of a number of Nd-fe-B-Cu alloys. Microstructural observation showed that both pressed and forged samples are characterized by a heterogeneous microstructure and from magnetic measurements it was concluded that magnetic properties differ when taken in the center or in the periphery of the sample. On the other hand roller magnets were homogeneous both in terms of microstructure and magnetic properties, and interpretations of the mechanisms of texture development and of microstructural development of hot deformed magnets is put forward. (author)

  12. The Development of Magnetic Molecules for the Selective Removal of Contaminants

    International Nuclear Information System (INIS)

    Bushart, S.P.; Bradbury, D.; Elder, G.; Duffield, J.; Pascual, I.; Ratcliffe, N.

    2006-01-01

    'Magnetic molecules' are a new type of decontaminant for removing dilute dissolved contaminants from solution. Magnetic molecules have a specific ion exchange function to selectively react with a particular type of ionic contamination in a liquid solution. The magnetic molecules also have a very small magnetic ferritin core (ferritin is an iron-III mammalian storage protein having about 10 nm diameter), which enables the magnetic molecule to be removed from solution by magnetic filtration. The ion exchange function is attached to the magnetic ferritin core by organic reaction sequences. The ion exchange function selectively bonds to a specific type of contaminant ion. For example, ion exchange functions can selectively target radioactive contaminant ions such as cobalt, cesium and plutonium. The procedure for decontamination is that the appropriate magnetic molecule (which targets the contaminant which it is desired to remove) is added to the solution and the solution is then passed through a magnetic filter. The contaminant binds to the magnetic molecule and is then removed by the magnetic filter. The magnetic molecule/contaminant can then be recovered from the magnetic filter by back-washing. Work has been undertaken towards the development of magnetic molecules for use as radioactive decontaminants for radioactive waste management purposes. Previously we have reported on the functionalization of ferritin with the chelating agent DTPA and have shown that this can be used to bind Ca(II) in solution and separate it from Na(I) ions by the process of equilibrium dialysis. Approximately 100 DTPA molecules could be bound to the surface of the ferritin molecule. Synthetic conditions have been optimised, and which will be reported here, ferritin has been functionalized with approximately 1200 DTPA molecules per mole of ferritin and used successfully to achieve a quantitative separation of Co(II) from Cs(I) ions by equilibrium dialysis. This separation has been carried

  13. Magnetoelastic coupling in glassy Fe(91)-Zr(9)

    International Nuclear Information System (INIS)

    Balakrishnan, K.; Ganesan, V.; Srinivasan, R.; Babu, P.D.

    1996-01-01

    The study of elastic properties of amorphous magnetic materials of the type iron rich Fe-Zr is interesting both in fundamental as well in applied aspects. In basic research, it provides an opportunity to understand the mechanism of magnetism and to understand the nature of coupling between the magnetic energy with the elastic strain field

  14. Magnetic Resonance Imaging: A Tool for Pork Pie Development

    Directory of Open Access Journals (Sweden)

    Adam P. Gaunt

    2013-08-01

    Full Text Available The traditional British pork pie consists of roughly chopped pork cooked in a hot water pastry crust. Due to shrinkage of the meat during cooking, the gap formed around the meat is usually sealed using a gelatin based jelly to exclude air and thus help to preserve the pie. The properties of the jelly are such that it will ingress into the pastry crust causing undesirable softening. The jelly is traditionally produced by simmering pig trotters with seasoning for several hours. In this work we demonstrate the potential of magnetic resonance imaging (MRI as a tool for investigating the conditions required for producing jellies with different properties and present two examples of this use. Firstly we demonstrate that MRI can determine the ability of water to diffuse through the jelly which is critical in minimizing the amount of moisture moving from the jelly to the crust. Secondly, the impact of jelly temperature on the penetration length into the crust is investigated. These examples highlight the power of MRI as a tool for food assessment.

  15. Magnetic Resonance Imaging: A Tool for Pork Pie Development

    Science.gov (United States)

    Gaunt, Adam P.; Morris, Robert H.; Newton, Michael I.

    2013-01-01

    The traditional British pork pie consists of roughly chopped pork cooked in a hot water pastry crust. Due to shrinkage of the meat during cooking, the gap formed around the meat is usually sealed using a gelatin based jelly to exclude air and thus help to preserve the pie. The properties of the jelly are such that it will ingress into the pastry crust causing undesirable softening. The jelly is traditionally produced by simmering pig trotters with seasoning for several hours. In this work we demonstrate the potential of magnetic resonance imaging (MRI) as a tool for investigating the conditions required for producing jellies with different properties and present two examples of this use. Firstly we demonstrate that MRI can determine the ability of water to diffuse through the jelly which is critical in minimizing the amount of moisture moving from the jelly to the crust. Secondly, the impact of jelly temperature on the penetration length into the crust is investigated. These examples highlight the power of MRI as a tool for food assessment. PMID:28239124

  16. Determination of Volatility and Element Fractionation in Glassy Fallout Debris by SIMS

    Energy Technology Data Exchange (ETDEWEB)

    Williamson, Todd L. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Tenner, Travis Jay [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Bonamici, Chloe Elizabeth [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Kinman, William Scott [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Pollington, Anthony Douglas [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Steiner, Robert Ernest [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-05-10

    The purpose of this report is to characterize glassy fallout debris using the Trinity Test and then characterize the U-isotopes of U3O8 reference materials that contain weaponized debris.

  17. Sub-nanoscale nanoimprint fabrication of atomically stepped glassy substrates of silicate glass and acryl polymer

    Science.gov (United States)

    Yoshimoto, Mamoru

    2015-11-01

    In the nanoimprint process, the resolution limit of patterning has attracted much attention from both scientific and industrial aspects. In this article, we briefly review the main achievements of our research group on sub-nanoscale nanoimprint fabrication of atomically patterned glassy substrates of oxide glass and polymer. By applying the sapphire (α-Al2O3 single crystal) wafers with self-organized nanopatterns of atomic steps as thermal nanoimprinting molds, we successfully transferred their nanoscale patterns onto the surfaces of glassy substrates such as soda-lime silicate glasses and poly(methyl methacrylate) polymers. The surfaces of nanoimprinted glassy materials exhibited regularly arrayed atomic stairs with 0.2-0.3 nm step height, which were in good agreement with the sub-nanopatterns of sapphire molds. These atomically stepped morphologies on the glassy substrates were found to be stable for about 1 year.

  18. A wrinkling-based method for investigating glassy polymer film relaxation as a function of film thickness and temperature

    Science.gov (United States)

    Chung, Jun Young; Douglas, Jack F.; Stafford, Christopher M.

    2017-10-01

    We investigate the relaxation dynamics of thin polymer films at temperatures below the bulk glass transition Tg by first compressing polystyrene films supported on a polydimethylsiloxane substrate to create wrinkling patterns and then observing the slow relaxation of the wrinkled films back to their final equilibrium flat state by small angle light scattering. As with recent relaxation measurements on thin glassy films reported by Fakhraai and co-workers, we find the relaxation time of our wrinkled films to be strongly dependent on film thickness below an onset thickness on the order of 100 nm. By varying the temperature between room temperature and Tg (≈100 °C), we find that the relaxation time follows an Arrhenius-type temperature dependence to a good approximation at all film thicknesses investigated, where both the activation energy and the relaxation time pre-factor depend appreciably on film thickness. The wrinkling relaxation curves tend to cross at a common temperature somewhat below Tg, indicating an entropy-enthalpy compensation relation between the activation free energy parameters. This compensation effect has also been observed recently in simulated supported polymer films in the high temperature Arrhenius relaxation regime rather than the glassy state. In addition, we find that the film stress relaxation function, as well as the height of the wrinkle ridges, follows a stretched exponential time dependence and the short-time effective Young's modulus derived from our modeling decreases sigmoidally with increasing temperature—both characteristic features of glassy materials. The relatively facile nature of the wrinkling-based measurements in comparison to other film relaxation measurements makes our method attractive for practical materials development, as well as fundamental studies of glass formation.

  19. Iron Oxide Nanoparticle-Based Magnetic Ink Development for Fully Printed Tunable Radio-Frequency Devices

    KAUST Repository

    Vaseem, Mohammad

    2018-01-30

    The field of printed electronics is still in its infancy and most of the reported work is based on commercially available nanoparticle-based metallic inks. Although fully printed devices that employ dielectric/semiconductor inks have recently been reported, there is a dearth of functional inks that can demonstrate controllable devices. The lack of availability of functional inks is a barrier to the widespread use of fully printed devices. For radio-frequency electronics, magnetic materials have many uses in reconfigurable components but rely on expensive and rigid ferrite materials. A suitable magnetic ink can facilitate the realization of fully printed, magnetically controlled, tunable devices. This report presents the development of an iron oxide nanoparticle-based magnetic ink. First, a tunable inductor is fully printed using iron oxide nanoparticle-based magnetic ink. Furthermore, iron oxide nanoparticles are functionalized with oleic acid to make them compatible with a UV-curable SU8 solution. Functionalized iron oxide nanoparticles are successfully embedded in the SU8 matrix to make a magnetic substrate. The as-fabricated substrate is characterized for its magnetostatic and microwave properties. A frequency tunable printed patch antenna is demonstrated using the magnetic and in-house silver-organo-complex inks. This is a step toward low-cost, fully printed, controllable electronic components.

  20. Development of controlled solid-state alignment for alnico permanent magnets in near-final shape

    Science.gov (United States)

    Anderson, Iver E.; Kassen, Aaron G.; White, Emma M. H.; Palasyuk, Andriy; Zhou, Lin; Tang, Wei; Kramer, Matthew J.

    2017-05-01

    The 2011 price shock in the rare earth (RE) permanent magnet (PM) marketplace precipitated realization of extremely poor RE supply diversity and drove renewed research in RE-free permanent magnets such as "alnico." Essentially, alnico is an Al-Ni-Co-Fe alloy with high magnetic saturation and TC, but low coercivity. It also was last researched extensively in the 1970's. Currently alnico "9" magnets with the highest energy product (10MGOe) are manufactured by directional solidification to make highly aligned anisotropic magnets. This work developed novel powder processing techniques to improve on unaligned anisotropic alnico "8H" with elevated coercivity. Gas atomization was used to produce pre-alloyed powder for binder-assisted compression molding of near-final shape magnets that were vacuum sintered to full density (direction. Evaluation of heavily stressed samples (>250g) showed reduced overall loop squareness compared to unaligned (equiaxed) 8H due to grain rotation-induced misalignment, while low stresses improved squareness and greatly improved alignment compared to equiaxed magnets, with squareness approaching 0.30 and remanence ratio as high as 0.79.

  1. Development of FEMAG. Calculation code of magnetic field generated by ferritic plates in the tokamak devices

    Energy Technology Data Exchange (ETDEWEB)

    Urata, Kazuhiro [Japan Atomic Energy Research Inst., Naka, Ibaraki (Japan). Naka Fusion Research Establishment

    2003-03-01

    In design of the future fusion devises in which low activation ferritic steel is planned to use as the plasma facing material and/or the inserts for ripple reduction, the appreciation of the error field effect against the plasma as well as the optimization of ferritic plate arrangement to reduce the toroidal field ripple require calculation of magnetic field generated by ferritic steel. However iterative calculations concerning the non-linearity in B-H curve of ferritic steel disturbs high-speed calculation required as the design tool. In the strong toroidal magnetic field that is characteristic in the tokamak fusion devices, fully magnetic saturation of ferritic steel occurs. Hence a distribution of magnetic charges as magnetic field source is determined straightforward and any iteration calculation are unnecessary. Additionally objective ferritic steel geometry is limited to the thin plate and ferritic plates are installed along the toroidal magnetic field. Taking these special conditions into account, high-speed calculation code ''FEMAG'' has been developed. In this report, the formalization of 'FEMAG' code, how to use 'FEMAG', and the validity check of 'FEMAG' in comparison with a 3D FEM code, with the measurements of the magnetic field in JFT-2M are described. The presented examples are numerical results of design studies for JT-60 modification. (author)

  2. Development of controlled solid-state alignment for alnico permanent magnets in near-final shape

    Directory of Open Access Journals (Sweden)

    Iver E. Anderson

    2017-05-01

    Full Text Available The 2011 price shock in the rare earth (RE permanent magnet (PM marketplace precipitated realization of extremely poor RE supply diversity and drove renewed research in RE-free permanent magnets such as “alnico.” Essentially, alnico is an Al-Ni-Co-Fe alloy with high magnetic saturation and TC, but low coercivity. It also was last researched extensively in the 1970’s. Currently alnico “9” magnets with the highest energy product (10MGOe are manufactured by directional solidification to make highly aligned anisotropic magnets. This work developed novel powder processing techniques to improve on unaligned anisotropic alnico “8H” with elevated coercivity. Gas atomization was used to produce pre-alloyed powder for binder-assisted compression molding of near-final shape magnets that were vacuum sintered to full density (250g showed reduced overall loop squareness compared to unaligned (equiaxed 8H due to grain rotation-induced misalignment, while low stresses improved squareness and greatly improved alignment compared to equiaxed magnets, with squareness approaching 0.30 and remanence ratio as high as 0.79.

  3. Dielectric relaxation in glassy Se75In25− xPbx alloys

    Indian Academy of Sciences (India)

    In this paper we report the effect of Pb incorporation in the dielectric properties of a-Se75In25 glassy alloy. The temperature and frequency dependence of the dielectric constants and the dielectric losses in glassy Se75In25−Pb ( = 0, 5, 10 and 15) alloys in the frequency range (1 kHz–5 MHz) and temperature range ...

  4. MAGNET

    CERN Multimedia

    B. Curé

    The first phase of the commissioning ended in August by a triggered fast dump at 3T. All parameters were nominal, and the temperature recovery down to 4.5K was carried out in two days by the cryogenics. In September, series of ramps were achieved up to 3 and finally 3.8T, while checking thoroughly the detectors in the forward region, measuring any movement of and around the HF. After the incident of the LHC accelerator on September 19th, corrective actions could be undertaken in the forward region. When all these displacements were fully characterized and repetitive, with no sign of increments in displacement at each field ramp, it was possible to start the CRAFT, Cosmic Run at Four Tesla (which was in fact at 3.8T). The magnet was ramped up to 18.16kA and the 3 week run went smoothly, with only 4 interruptions: due to the VIP visits on 21st October during the LHC inauguration day; a water leak on the cooling demineralized water circuit, about 1 l/min, that triggered a stop of the cooling pumps, and resulte...

  5. MAGNET

    CERN Multimedia

    Benoit Curé

    The cooling down to the nominal temperature of 4.5 K was achieved at the beginning of August, in conjunction with the completion of the installation work of the connection between the power lines and the coil current leads. The temperature gradient on the first exchanger of the cold box is now kept within the nominal range. A leak of lubricant on a gasket of the helium compressor station installed at the surface was observed and several corrective actions were necessary to bring the situation back to normal. The compressor had to be refilled with lubricant and a regeneration of the filters and adsorbers was necessary. The coil cool down was resumed successfully, and the cryogenics is running since then with all parameters being nominal. Preliminary tests of the 20kA coil power supply were done earlier at full current through the discharge lines into the dump resistors, and with the powering busbars from USC5 to UXC5 without the magnet connected. On Monday evening August 25th, at 8pm, the final commissionin...

  6. MAGNET

    CERN Multimedia

    Benoit Curé

    2013-01-01

    Maintenance work and consolidation activities on the magnet cryogenics and its power distribution are progressing according to the schedules. The manufacturing of the two new helium compressor frame units has started. The frame units support the valves, all the sensors and the compressors with their motors. This activity is subcontracted. The final installation and the commissioning at CERN are scheduled for March–April 2014. The overhauls of existing cryogenics equipment (compressors, motors) are in progress. The reassembly of the components shall start in early 2014. The helium drier, to be installed on the high-pressure helium piping, has been ordered and will be delivered in the first trimester of 2014. The power distribution for the helium compressors in SH5 on the 3.3kV network is progressing. The 3.3kV switches, between each compressor and its hot spare compressor, are being installed, together with the power cables for the new compressors. The 3.3kV electrical switchboards in SE5 will ...

  7. Positron annihilation study of graphite, glassy carbon and C60/C70 fullerene

    International Nuclear Information System (INIS)

    Hasegawa, Masayuki; Kajino, Masahiro; Yamaguchi, Sadae; Iwata, Tadao; Kuramoto, Eiichi; Takenaka, Minoru.

    1992-01-01

    ACAR (Angular Correlation of Annihilation Radiation) and positron lifetime measurements have been made on, HOPG (Highly Oriented Pyrolytic Graphite), isotropic fine-grained graphite, glassy carbons and C 60 /C 70 powder. HOPG showed marked bimodality along the c-axis and anisotropy in ACAR momentum distribution, which stem from characteristic annihilation between 'interlayer' positrons and π-electrons in graphite. ACAR curves of the isotropic graphite and glassy carbons are even narrower than that of HOPG perpendicular to the c-axis. Positron lifetime of 420 and 390 - 480 psec, much longer than that of 221 psec in HOPG, were observed for the isotropic graphite and glassy carbons respectively, which are due to positron trapping in structural voids in them. Positron lifetime and ACAR width (FWHM) can be well correlated to void sizes (1.7 to 5.0 nm) of glassy carbons which have been determined by small angle neutron (SAN) scattering measurements. ACAR curves and positron lifetime of C 60 /C 70 powder agree well with those of glassy carbons. This shows that positron wave functions extend, as in the voids of glassy carbons, much wider than open spaces of the octahedral interstices of the face-centered cubic (FCC) structure of C 60 crystal and strongly suggests positron trapping in the 'soccer ball' vacancy. Possible positron states in the carbon materials are discussed with a simple model of void volume-trapping. Preliminary results on neutron irradiation damage in HOPG are also presented. (author)

  8. Development of Modeling and Simulation for Magnetic Particle Inspection Using Finite Elements

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jun-Youl [Iowa State Univ., Ames, IA (United States)

    2003-01-01

    Magnetic particle inspection (MPI) is a widely used nondestructive inspection method for aerospace applications essentially limited to experiment-based approaches. The analysis of MPI characteristics that affect sensitivity and reliability contributes not only reductions in inspection design cost and time but also improvement of analysis of experimental data. Magnetic particles are easily attracted toward a high magnetic field gradient. Selection of a magnetic field source, which produces a magnetic field gradient large enough to detect a defect in a test sample or component, is an important factor in magnetic particle inspection. In this work a finite element method (FEM) has been employed for numerical calculation of the MPI simulation technique. The FEM method is known to be suitable for complicated geometries such as defects in samples. This thesis describes the research that is aimed at providing a quantitative scientific basis for magnetic particle inspection. A new FEM solver for MPI simulation has been developed in this research for not only nonlinear reversible permeability materials but also irreversible hysteresis materials that are described by the Jiles-Atherton model. The material is assumed to have isotropic ferromagnetic properties in this research (i.e., the magnetic properties of the material are identical in all directions in a single crystal). In the research, with a direct current field mode, an MPI situation has been simulated to measure the estimated volume of magnetic particles around defect sites before and after removing any external current fields. Currently, this new MPI simulation package is limited to solving problems with the single current source from either a solenoid or an axial directional current rod.

  9. Development of a high gradient rf system using a nanocrystalline soft magnetic alloy

    Directory of Open Access Journals (Sweden)

    Chihiro Ohmori

    2013-11-01

    Full Text Available The future high intensity upgrade project of the J-PARC (Japan Proton Accelerator Research Complex MR (Main Ring includes developments of high gradient rf cavities and magnet power supplies for high repetition rate. The scenario describing the cavity replacements is reported. By the replacement plan, the total acceleration voltage will be almost doubled, while the number of rf stations remains the same. The key issue is the development of a high gradient rf system using high impedance magnetic alloy, FT3L. The FT3L is produced by the transverse magnetic field annealing although the present cavity for the J-PARC adopts the magnetic alloy, FT3M, which is annealed without magnetic field. After the test production using a large spectrometer magnet in 2011, a dedicated production system for the FT3L cores was assembled in 2012. This setup demonstrated that we can produce material with 2 times higher μ_{p}^{′}Qf product compared to the cores used for present cavities. In this summer, the production system was moved to the company from J-PARC and is used for mass production of 280 FT3L cores for the J-PARC MR. The cores produced in the first test production are already used for standard machine operation. The operation experience shows that the power loss in the cores was reduced significantly as expected.

  10. Magnets for the Mirror Fusion Test Facility: testing of the first Yin-Yang and the design and development of other magnets

    International Nuclear Information System (INIS)

    Kozman, T.A.; Wang, S.T.; Chang, Y.

    1983-01-01

    Completed in May 1981, the first Yin-Yang magnet for the tandem Mirror Fusion Test Facility (MFTF-B) at Lawrence Livermore National Laboratory (LLNL) was successfully tested in February 1982 to its full design field (7.68 T) and current (5775 A). Since that time, the entire magnet array has been reconfigured - from the original A-cell to an axicell design. The MFTF-B magnet array now contains a total of 26 large superconducting coils: 2 sets of yin-yang pairs, 2 sets of transition magnets (each containing two coils), 2 sets of axicell magnets (each containing three coils), and 12 central-cell solenoids. This paper chronicles recent magnet history - from te testing of the initial yin-yang set, through the design of the axicell configuration, to the planned development of the system

  11. Language Development and Brain Magnetic Resonance Imaging Characteristics in Preschool Children with Cerebral Palsy

    Science.gov (United States)

    Choi, Ja Young; Choi, Yoon Seong; Park, Eun Sook

    2017-01-01

    Purpose: The purpose of this study was to investigate characteristics of language development in relation to brain magnetic resonance imaging (MRI) characteristics and the other contributing factors to language development in children with cerebral palsy (CP). Method: The study included 172 children with CP who underwent brain MRI and language…

  12. Developing a Magnetic Circular Dichroism Apparatus Equipped with Neodymium Magnet for Students to Investigate the Electronic Structures of Transition Metals and Lanthanoids

    Science.gov (United States)

    Yakubu, Abdallah; Suzuki, Takayoshi; Kita, Masakazu

    2017-01-01

    This paper describes the development of a simple magnetic circular dichroism (MCD) apparatus from a wood base and neodymium magnets and its configuration in the Faraday alignment. The applicability and effectiveness of the apparatus for MCD spectra measurements have been examined. The apparatus was used by undergraduate students to conduct MCD…

  13. Activation of glassy carbon electrodes by photocatalytic pretreatment

    Energy Technology Data Exchange (ETDEWEB)

    Dumanli, Onur [Department of Chemistry, Faculty of Science and Art, Ondokuz Mayis University, Kurupelit, 55139 Samsun (Turkey); Onar, A. Nur [Department of Chemistry, Faculty of Science and Art, Ondokuz Mayis University, Kurupelit, 55139 Samsun (Turkey)], E-mail: nonar@omu.edu.tr

    2009-11-01

    This paper describes a simple and rapid photocatalytic pretreatment procedure that removes contaminants from glassy carbon (GC) surfaces. The effectiveness of TiO{sub 2} mediated photocatalytic pretreatment procedure was compared to commonly used alumina polishing procedure. Cyclic voltammetric and chronocoulometric measurements were carried out to assess the changes in electrode reactivity by using four redox systems. Electrochemical measurements obtained on photocatalytically treated GC electrodes showed a more active surface relative to polished GC. In cyclic voltammograms of epinephrine, Fe(CN){sub 6}{sup 3-/4-} and ferrocene redox systems, higher oxidation and reduction currents were observed. The heterogeneous electron transfer rate constants (k{sup o}) were calculated for Fe(CN){sub 6}{sup 3-/4-} and ferrocene which were greater for photocatalytic pretreatment. Chronocoulometry was performed in order to find the amount of adsorbed methylene blue onto the electrode and was calculated as 0.34 pmol cm{sup -2} for photocatalytically pretreated GC. The proposed photocatalytic GC electrode cleansing and activating pretreatment procedure was more effective than classical alumina polishing.

  14. Electrochemical determination of mesotrione at organoclay modified glassy carbon electrodes.

    Science.gov (United States)

    Kamga Wagheu, Josephine; Forano, Claude; Besse-Hoggan, Pascale; Tonle, Ignas K; Ngameni, Emmanuel; Mousty, Christine

    2013-01-15

    A natural Cameroonian smectite-type clay (SaNa) was exchanged with cationic surfactants, namely cetyltrimethylammonium (CTA) and didodecyldimethyl ammonium (DDA) modifying its physico-chemical properties. The resulting organoclays that have higher adsorption capacity for mesotrione than the pristine SaNa clay, have been used as modifiers of glassy carbon electrode for the electrochemical detection of this herbicide by square wave voltammetry. The stripping performances of SaNa, SaCTA and SaDDA modified electrodes were therefore evaluated and the experimental parameters were optimized. SaDDA gives the best results in deoxygenated acetate buffer solution (pH 6.0) after 2 min accumulation under open circuit conditions. Under optimal conditions, the reduction current is proportional to mesotrione concentration in the range from 0.25 to 2.5 μM with a detection limit of 0.26 μM. The fabricated electrode was also applied for the commercial formulation CALLISTO, used in European maize market. Copyright © 2012 Elsevier B.V. All rights reserved.

  15. Delocalized glassy dynamics and many-body localization

    Science.gov (United States)

    Biroli, G.; Tarzia, M.

    2017-11-01

    We analyze the unusual slow dynamics that emerges in the bad metal delocalized phase preceding the many-body localization transition by using single-particle Anderson localization on the Bethe lattice as a toy model of many-body dynamics in Fock space. We probe the dynamical evolution by measuring observables such as the imbalance and equilibrium correlation functions, which display slow dynamics and power laws strikingly similar to those observed in recent simulations and experiments. We relate this unusual behavior to the nonergodic spectral statistics found on Bethe lattices. We discuss different scenarios, such as a true intermediate phase which persists in the thermodynamic limit versus a glassy regime established on finite but very large time and length scales only, and their implications for real-space dynamical properties. In the latter, slow dynamics and power laws extend on a very large time window but are eventually cut off on a time scale that diverges at the many-body localization transition.

  16. A conceptual magnetic fabric development model for the Paks loess in Hungary

    Science.gov (United States)

    Bradák, B.; Újvári, G.; Seto, Y.; Hyodo, M.; Végh, T.

    2018-02-01

    We describe magnetic fabric and depositional environments of aeolian (loess) deposits from Paks, Hungary, and develop a novel, complex conceptual sedimentation model based on grain size and low-field magnetic susceptibility anisotropy data. A plot of shape factor (magnetic fabric parameter) and dry deposition velocity estimated from grain-size reveals primary and secondary depositional processes during the sedimentation of loess. Primary ones are driven by gravity, with poorly oriented MF for fine grain materials, and by tangential stress, with flow-aligned or flow-transverse fabric for coarser grain sediments. The fabric developed by a primary process is called depositional magnetic fabric. Secondary processes develop in unconsolidated sediments, beginning right after deposition and terminating before the start of diagenesis. Under slow sedimentation conditions, deposited materials are likely to be exposed near the surface for longer periods. Therefore, relatively strong winds with a stable direction can alter the fabric of non-buried surficial sediments. As a result, grain orientations may change from scattered, non-flow oriented fabric to flow-oriented fabric. This type of fabric, developed by a secondary process, is called transformed magnetic fabric, and is characterized by relatively well-defined grain orientation, which allows us to estimate a dominant wind direction.

  17. Differential pulse anodic voltammetric determination of pantoprazole in pharmaceutical dosage forms and human plasma using glassy carbon electrode.

    Science.gov (United States)

    Erk, Nevin

    2003-12-01

    Pantoprazole is used as an anti-ulcer drug through inhibition of H(+), K(+)-adenosine 5(')-triphosphatase in gastric parietal cells. It reduces the gastric acid secretion regardless of the nature of stimulation. The use of differential pulse voltammetry for the determination of pantoprazole in pharmaceutical dosage forms and human plasma using a glassy carbon electrode has been examined. The best voltammetric response was reached for a glassy carbon electrode in Britton-Robinson buffer solution of pH 5.0 submitted to a scan rate of 20.0 mVs(-1) and a pulse amplitude of 50.0 mV. This electroanalytical procedure was able to determine pantoprazole in the concentration range 6.0 x 10(-6)-8.0 x 10(-4)M. Precision and accuracy of the developed method was checked with recovery studies. The limit of detection and limit of quantitation were found to be 4.0 x 10(-7) and 9.0 x 10(-7)M, respectively. Rapidity, precision, and good selectivity were also found for the determination of pantoprazole in pharmaceutical dosage forms and human plasma. For comparative purposes high-performance liquid chromatography with a diode array and UV/VIS detection at 290.0 nm determination also was developed.

  18. Magnetic resonance microscopy atlas of equine embryonic development

    NARCIS (Netherlands)

    Jenner, F; Närväinen, J; de Ruijter-Villani, M; Stout, T A E; van Weeren, P R; Brama, P

    2014-01-01

    REASONS FOR PERFORMING STUDY: Equine embryogenesis post implantation is not well studied, and only two-dimensional illustrations are available. A thorough appreciation of the complex three-dimensional relationship between tissues and organs and their development is, however, crucial for

  19. Development of high magnetic field soft X-ray spectroscopy and its application to the study of surface and interface

    International Nuclear Information System (INIS)

    Nakamura, Tetsuya; Narumi, Yasuo

    2014-01-01

    Magnetic materials are generally synthesized and used as alloys and compounds. They are also stacked as a multilayer film for spintronics device such as a reading-head sensor of a hard disk drive. The evaluation of magnetization is the most fundamental characterization in studies of magnetic materials. Especially, in alloys and compounds involving more than two magnetic elements, a partial magnetization with respect to each element, we call as an element specific magnetization, promises to provide the deeper understanding of their magnetic property. X-ray magnetic circular dichroism (XMCD) in absorption spectroscopy provides an element specific magnetization. As XMCD became increasingly popular, high-magnetic-field environment for XMCD measurements also became very important in order to investigate paramagnetic, antiferromagnetic, and meta-magnetic materials. Under the circumstance, a high-magnetic-field XMCD measurement technique of the soft-X-ray regime has been developed using a non-destructive pulse magnet having capability of generating 40 T at the twin helical undulators beamline, BL25SU, of SPring-8. In this review, we first introduce the concept and the technical features of high magnetic field XMCD and then show recent examples of the experiments. (author)

  20. Developing a magnetic resonance imaging scoring system for peripheral psoriatic arthritis

    DEFF Research Database (Denmark)

    McQueen, Fiona; Lassere, Marissa; Bird, Paul

    2007-01-01

    We describe the first steps in developing an OMERACT magnetic resonance imaging (MRI) scoring system for peripheral psoriatic arthritis (PsA). A preexisting MRI dataset (finger joints) from 10 patients with PsA was scored by 4 readers for bone erosion, bone edema, synovitis, tendinopathy, and ext......We describe the first steps in developing an OMERACT magnetic resonance imaging (MRI) scoring system for peripheral psoriatic arthritis (PsA). A preexisting MRI dataset (finger joints) from 10 patients with PsA was scored by 4 readers for bone erosion, bone edema, synovitis, tendinopathy...

  1. Development and application of magnetic magnesium for data storage in gentelligent products

    International Nuclear Information System (INIS)

    Wu, K.-H.; Gastan, E.; Rodman, M.; Behrens, B.-A.; Bach, Fr.-W.; Gatzen, H.H.

    2010-01-01

    A new concept aims at developing genetically intelligent ('gentelligent') components, which bequeath production or application data to their next generation. For such an approach, it is desirable to store respective information on the component itself. This is accomplished by using its surface to store magnetic data on it. This way, the component itself can be used as its own information carrier throughout the manufacturing process and later throughout the working cycle. The chosen approach is to develop a magnetic magnesium (Mg), integrate it in an appropriate component, and subject the component to recording experiments.

  2. Possibilities of development photodynamic therapy under high temperature superconductor magnetic field

    International Nuclear Information System (INIS)

    Sen, Mihir

    1996-01-01

    After a long extensive research work neutron photon therapy for treatment of acquired immuno-deficiency syndrome (AIDS) was developed. High temperature superconductor magnet was developed and fitted in magnetic resonance imaging system to guide the patient. By this neutron-photon therapy AIDS effected cells are identified prominently. Patient is then injected with light sensitive drug molecules, which only AIDS cell retain. Light from photon (laser) then energizes the drug, which passes that energy to oxygen, which then leads a biochemical attack on the AIDS cells. If all goes well, the AIDS affected cells die. 10 refs., 1 fig

  3. Application and development of advanced Lorentz microscopy techniques for the study of magnetic nanostructures

    Science.gov (United States)

    Beacham, Robert J.

    This PhD project presents an investigation into the development of magnetic imaging methods in the TEM and their application in imaging narrow domain walls in multilayer magnetic structures. Lorentz microscopy techniques are limited in quantitative magnetic imaging as this generally requires using scanning imaging modes which limits the capability of imaging dynamic processes. The first imaging method developed in this study is a phase gradient technique with the aim of producing quantitative magnetic contrast proportional to the magnetic induction of the sample whilst maintaining a live imaging mode. This method uses a specifically engineered, semi-electron-transparent graded wedge aperture to controllably perturb intensity in the back focal plane. The results of this study found that this method could produce magnetic contrast proportional to the sample induction, however the required gradient of the wedge aperture made this contrast close to the noise level with large associated errors. In the second part of this study we investigated the development of a technique aimed at gaining sub-microsecond temporal resolution within TEMs based on streak imaging. We are using ramped pulsed magnetic fields, applied across nanowire samples to both induce magnetic behaviour and detect the electron beam across the detector with respect to time. We are coupling this with a novel pixelated detector on the TEM in the form of a Medipix/Timepix chip capable of microsecond exposure times without adding noise. Running this detector in integral mode and allowing for practical limitations such as experiment time and aperture stability, the resultant streak images were taken in Fresnel, Foucault and low angle diffraction imaging modes. We found that while this method is theoretically viable, the limiting factor was the contrast of the magnetic signal in the streak and therefore the total image counts. Domain walls (DWs) in synthetic antiferromagnetically (SAF) coupled films patterned

  4. WInd-and-react Bi-2212 coil development for accelerator magnets

    Energy Technology Data Exchange (ETDEWEB)

    Godeke, A.; Acosta, P.; Cheng, D.; Dietderich, D. R.; Mentink, M. G. T.; Prestemon, S. O.; Meinesz, M.; Hong, S.; Huang, Y.; Miao, H.; Parrell, J.; Sabbi, G.L.

    2009-10-13

    Sub-scale coils are being manufactured and tested at Lawrence Berkeley National Laboratory in order to develop wind-and-react Bi{sub 2}Sr{sub 2}CaCu{sub 2}O{sub x} (Bi-2212) magnet technology for future graded accelerator magnet use. Previous Bi-2212 coils showed significant leakage of the conductors core constituents to the environment, which can occur during the partial melt reaction around 890 C in pure oxygen. The main origin of the observed leakage is intrinsic leakage of the wires, and the issue is therefore being addressed at the wire manufacturing level. We report on further compatibility studies, and the performance of new sub-scale coils that were manufactured using improved conductors. These coils exhibit significantly reduced leakage, and carry currents that are about 70% of the witness wire critical current (I{sub c}). The coils demonstrate, for the first time, the feasibility of round wire Bi-2212 conductors for accelerator magnet technology use. Successful high temperature superconductor coil technology will enable the manufacture of graded accelerator magnets that can surpass the, already closely approached, intrinsic magnetic field limitations of Nb-based superconducting magnets.

  5. Development of volume reduction method of cesium contaminated soil with magnetic separation

    International Nuclear Information System (INIS)

    Yukumatsu, Kazuki; Nomura, Naoki; Mishima, Fumihito; Akiyama, Yoko; Nishijima, Shigehiro

    2016-01-01

    In this study, we developed a new volume reduction technique for cesium contaminated soil by magnetic separation. Cs in soil is mainly adsorbed on clay which is the smallest particle constituent in the soil, especially on paramagnetic 2:1 type clay minerals which strongly adsorb and fix Cs. Thus selective separation of 2:1 type clay with a superconducting magnet could enable to reduce the volume of Cs contaminated soil. The 2:1 type clay particles exist in various particle sizes in the soil, which leads that magnetic force and Cs adsorption quantity depend on their particle size. Accordingly, we examined magnetic separation conditions for efficient separation of 2:1 type clay considering their particle size distribution. First, the separation rate of 2:1 type clay for each particle size was calculated by particle trajectory simulation, because magnetic separation rate largely depends on the objective size. According to the calculation, 73 and 89 % of 2:1 type clay could be separated at 2 and 7 T, respectively. Moreover we calculated dose reduction rate on the basis of the result of particle trajectory simulation. It was indicated that 17 and 51 % of dose reduction would be possible at 2 and 7 T, respectively. The difference of dose reduction rate at 2 T and 7 T was found to be separated a fine particle. It was shown that magnetic separation considering particle size distribution would contribute to the volume reduction of contaminated soil

  6. Adsorptive Stripping Voltammetric Determination of Hydroquinone using an Electrochemically Pretreated Glassy Carbon Electrode

    Directory of Open Access Journals (Sweden)

    Abdul Niaz1,

    2008-12-01

    Full Text Available A simple and efficient adsorptive stripping voltammetric (AdSV method was developed for the determination of hydroquinone at an electrochemically pretreated glassy carbon (GC electrode in waste water. Various parameters such as solvent system, accumulation potential, accumulation time and scan rate were optimized. The electrochemically pretreated GC electrode showed good response towards hydroquinone determination by using AdSV. Under the optimized conditions the peak current showed good linear relationship with the hydroquinone concentration in the range of 0.5-4.0mg L-1 and 5-30mg L-1. The 60/40 methanol/water composition was found to be the best solvent system and 0.05mol L-1 H2SO4 was found as useful supporting electrolyte concentration. The accumulation time was 60 s and the detection limit was 50µg L-1. The developed method was successfully applied for the determination of hydroquinone in polymeric industrial discharge samples waste photographic developer solution and cream sample without any significant effect of surface fouling.

  7. World Digital Magnetic Anomaly Map, development towards the Second Edition. (Invited)

    Science.gov (United States)

    Korhonen, J. V.

    2009-12-01

    Magnetic anomalies are small deviations in the Earth’s main magnetic field, caused by variation of magnetization in the uppermost lithosphere. Magnetic anomalies provide spatial key information for understanding the structure and evolution of the Earths crust. In practice these anomalies are used e.g. for assessment and prospecting of geological natural resources and planning of land use. A common way to calculate a magnetic anomaly value has been to subtract International Geomagnetic Reference Field (IGRF) from a total field measurement that is cleaned from short term variation of the Earth's magnetic field. World Digital Magnetic Anomaly Map (WDMAM) is a collaborative project between member organizations of International Association of Geomagnetism and Aeronomy (IAGA) and the Commission for Geological Map of the World (CGMW). The First Edition of the map was published in 2007. It consisted of a paper map 1:50 Million and a 3 minutes global grid of total field anomalies at an altitude of 5 km above the geoid. The First Edition was aimed to compile as much as possible available land and sea magnetic data, and homogenize it by comparing anomalies with a satellite magnetic lithospheric field model. This first version was prepared in a tight schedule, to show the usefulness of the map to the community and to form a basis for later development and future editions of the map. Hence, much was left to be improved for the second edition, including sparse coverage in two continents and all southern seas. The satellite models were understood to gain more detail in near future when the CHAMP-satellite would reach lower orbits, and hence higher resolution. The SWARM-satellite constellation was seen to produce even more suitable data in a few years thereafter. Ocean magnetic data sets required careful processing and leveling. The method of homogenization of anomalies included replacing long wavelength information by satellite model spectral data, and hence rejecting

  8. Development of a precise long-time digital integrator for magnetic measurements in a tokamak

    Energy Technology Data Exchange (ETDEWEB)

    Kurihara, Kenichi; Kawamata, Youichi [Japan Atomic Energy Research Inst., Naka, Ibaraki (Japan). Naka Fusion Research Establishment

    1997-10-01

    Long-time D-T burning operation in a tokamak requires that a magnetic sensor must work in an environment of 14-MeV intense neutron field, and that the measurement system must output precise magnetic field values. A method of time-integration of voltage produced in a simple pick-up coil seems to have preferable features of good time response, easy maintenance, and resistance to neutron irradiation. However, an inevitably-produced signal drift makes it difficult to apply the method to the long-time integral operation. To solve this problem, we have developed a new digital integrator (a voltage-to-frequency converter and an up-down counter) with testing the trial boards in the JT-60 magnetic measurements. This reports all of the problems and their measures through the development steps in details, and shows how to apply this method to the ITER operation. (author)

  9. Development of magnetic materials for continuous ADR system; Uchu yo ADR jiseitai no kaihatsu

    Energy Technology Data Exchange (ETDEWEB)

    Numazawa, T.; Sato, A. [National Research Inst. of Metals, Tokyo (Japan); Arai, O. [Tokyo Inst. of Tech., Tokyo (Japan); Canavan, E.; Shirron, P.

    2000-05-29

    Next generation high resolution light quantum detector using micro-calorimeter such as XRS analyzing equipment mounted on Astro-E is at present under development. For these sensors, ultra-low temperature environment below 100 mK is indispensable, and a cooling system capable of generating ultra-low temperature under no coolant and no gravity is desired. This time, the Metallic Materials Research Institute participated in the development program of ADR for space proceeding in GSFC requested by NASA/Goddard space flight Center (GSFC). The feature of this cooling system is that magnetic materials are divided into multiple bodies in order to generate continuously 50 mK for realization of Carnot cycle. Ferric alum is used for lowest temperature generating magnetic material unit and use of DGGG magnetic material is under examination above 1 K. (NEDO)

  10. Design and Development of a Magneto-Optic Sensor for Magnetic Field Measurements

    Directory of Open Access Journals (Sweden)

    Sarbani CHAKRABORTY

    2015-01-01

    Full Text Available A magneto-optic sensor is developed using a Terbium Doped Glass (TDG element as a Faraday rotation sensor and optical fiber as light transmitting and receiving medium. Online LabView based application software is developed to process the sensor output. The system is used to sense the magnetic field of a DC motor field winding in industrial environment. The sensor output is compared with the magnetic flux density variation obtained with a calibrated Hall Magnetic sensor (Gauss Meter. A linear variation of sensor output over wide range of current passing through the field winding is obtained. Further the results show an improved sensitivity of magneto-optic sensor over the Hall sensor.

  11. Ulta-Low Temperature Properties of Amorphous and Glassy Materials

    Energy Technology Data Exchange (ETDEWEB)

    Douglas D. Osheroff

    2013-01-10

    During the grant period we made detailed studies of the dynamics of two level tunneling systems in glasses at very low temperature and by the application of AC and DC electric fields. Models have been developed that now account for both the formation and subsequent breaking of resonant tunneling pairs, and strongly bound pairs in a swept electric field. Perhaps most importantly, we saw a critical field in the polymeric glass Mylar, beyond which recovery following the application of a strong electric field is substantially modified from the predictions of current models. It was essential during the final grant period to see how general these new properties were by testing for them in a new and broader set of glasses. At the same time, the discovery that tunneling systems with nuclei possessing electric quadrupole moments that couple the TS behavior to magnetic fields was studied in this laboratory, using some of the probes that we alone employ. Finally, we were developing our own dielectric pulsed echo system, operating for the first time at the low energy splittings and hence temperatures at which interactions between TS are important. We combined this technique with the sudden application of both electric and strain fields to better understand the dynamics of the response of TS in glasses on a much shorter time scale than is possible with our established probes.

  12. An Easily Fabricated Electrochemical Sensor Based on a Graphene-Modified Glassy Carbon Electrode for Determination of Octopamine and Tyramine

    Science.gov (United States)

    Zhang, Yang; Zhang, Meiqin; Wei, Qianhui; Gao, Yongjie; Guo, Lijuan; Al-Ghanim, Khalid A.; Mahboob, Shahid; Zhang, Xueji

    2016-01-01

    A simple electrochemical sensor has been developed for highly sensitive detection of octopamine and tyramine by electrodepositing reduced graphene oxide (ERGO) nanosheets onto the surface of a glassy carbon electrode (GCE). The electrocatalytic oxidation of octopamine and tyramine is individually investigated at the surface of the ERGO modified glassy carbon electrode (ERGO/GCE) by using cyclic voltammetry (CV) and differential pulse voltammetry (DPV). Several essential factors including the deposition cycle of reduced graphene oxide nanosheets and the pH of the running buffer were investigated in order to determine the optimum conditions. Furthermore, the sensor was applied to the quantification of octopamine and tyramine by DPV in the concentration ranges from 0.5 to 40 μM and 0.1 to 25 μM, respectively. In addition, the limits of detection of octopamine and tyramine were calculated to be 0.1 μM and 0.03 μM (S/N = 3), respectively. The sensor showed good reproducibility, selectivity and stability. Finally, the sensor successfully detected octopamine and tyramine in commercially available beer with satisfactory recovery ranges which were 98.5%–104.7% and 102.2%–103.1%, respectively. These results indicate the ERGO/GCE based sensor is suitable for the detection of octopamine and tyramine. PMID:27089341

  13. Electrochemical determination of serotonin in urine samples based on metal oxide nanoparticles/MWCNT on modified glassy carbon electrode

    Directory of Open Access Journals (Sweden)

    Omolola E. Fayemi

    2017-04-01

    Full Text Available The electrochemical response of serotonin on the modified electrode based on multiwalled-carbon-nanotube (MWCNT doped respectively with nickel, zinc and iron oxide nanoparticles coating on glassy carbon electrode (GCE at physiological pH 7 was determined using cyclic voltammetry (CV and square wave voltammetry (SWV. The modified GCE/MWCNT-metal oxide electrodes exhibited excellent electrocatalytic activity towards the detection of serotonin at large peak current and lower oxidation potentials compared to other electrodes investigated. The dynamic range for the serotonin determination was between 5.98 × 10−3 μM to 62.8 μM with detection limits 118, 129 and 166 nM for GCE/MWCNT-NiO, GCE/MWCNT-ZnO and GCE/MWCNT-Fe3O4 sensors respectively. GCE-MWCNT-NiO was the best electrode in terms of serotonin current response, electrode stability, resistance to fouling and limit of detection towards the analyte. The developed sensors were found to be electrochemically stable, reusable, economically effective due to their extremely low operational cost, and have demonstrated good limit of detection, sensitivity and selectivity towards serotonin determination in urine samples. Keywords: Metal oxides nanoparticles, Multiwalled carbon nanotubes, Glassy carbon electrode, Serotonin, Cyclic voltammetry, Square wave voltammetry

  14. The influence of static magnetic field (50 mT) on development and motor behaviour of Tenebrio (Insecta, Coleoptera).

    Science.gov (United States)

    Todorović, Dajana; Marković, Tamara; Prolić, Zlatko; Mihajlović, Spomenko; Rauš, Snežana; Nikolić, Ljiljana; Janać, Branka

    2013-01-01

    There is considerable concern about potential effects associated with exposure to magnetic fields on organisms. Therefore, duration of pupa-adult development and motor behaviour of adults were analyzed in Tenebrio obscursus and T. molitor after exposure to static magnetic field (50 mT). The experimental groups were: Control (kept 5 m from the magnets), groups which pupae and adults were placed closer to the North pole, or closer to the South pole of magnetic dipole. The pupae were exposed to the magnetic field until the moment of adult eclosion. The pupa-adult development dynamics were recorded daily. Subsequently, behaviour (distance travelled, average speed and immobility) of adults exposed to the magnetic field was monitored in a circular open field arena. Static magnetic field did not affect pupa-adult developmental dynamic of examined Tenebrio species. Exposure to magnetic field did not significantly change motor behaviour of T. obscurus adults. The changes in the motor behaviour of T. molitor induced by static magnetic field were opposite in two experimental groups developed closer to the North pole or closer to the South pole of magnetic dipole. Static magnetic field (50 mT) did not affect on pupa-adult development dynamic of two examined Tenebrio species, but modulated their motor behaviour.

  15. Recent developments in Liquid Phase Electroepitaxial growth of bulk crystals under magnetic field

    Science.gov (United States)

    Dost, Sadik; Lent, Brian; Sheibani, Hamdi; Liu, Yongcai

    2004-05-01

    This review article presents recent developments in Liquid Phase Electroepitaxial (LPEE) growth of bulk single crystals of alloy semiconductors under an applied static magnetic field. The growth rate in LPEE is proportional to the applied electric current. However, at higher electric current levels the growth becomes unstable due to the strong convection occurring in the liquid zone. In order to address this problem, a significant body of research has been performed in recent years to suppress and control the natural convection for the purpose of prolonging the growth process to grow larger crystals. LPEE growth experiments show that the growth rate under an applied static magnetic field is also proportional and increases with the field intensity level. The modeling of LPEE growth under magnetic field was also the subject of interest. Two-dimensional mathematical models developed for the LPEE growth process predicted that the natural convection in the liquid zone would be suppressed almost completely with increasing the magnetic field level. However, experiments and also three-dimensional models have shown that there is an optimum magnetic field level below which the growth process is stable and the convection in the liquid zone is suppressed, but above such a field level the convective flow becomes very strong and leads to unstable growth with unstable interfaces. To cite this article: S. Dost et al., C. R. Mecanique 332 (2004).

  16. Electrochemical oxidation of butein at glassy carbon electrodes.

    Science.gov (United States)

    Tesio, Alvaro Yamil; Robledo, Sebastián Noel; Fernández, Héctor; Zon, María Alicia

    2013-06-01

    The electrochemical oxidation of flavonoid butein is studied at glassy carbon electrodes in phosphate and citrate buffer solutions of different pH values, and 1M perchloric acid aqueous solutions by cyclic and square wave voltammetries. The oxidation peak corresponds to the 2e(-), 2H(+) oxidation of the 3,4-dihydroxy group in B ring of butein, given the corresponding quinone species. The overall electrode process shows a quasi-reversible behavior and an adsorption/diffusion mixed control at high butein bulk concentrations. At low butein concentrations, the electrode process shows mainly an adsorption control. Butein surface concentration values were obtained from the charge associated with the adsorbed butein oxidation peaks, which are in agreement with those values expected for the formation of a monolayer of adsorbate in the concentration range from 1 to 5μM. Square wave voltammetry was used to perform a full thermodynamic and kinetics characterization of the butein surface redox couple. Therefore, from the combination of the "quasi-reversible maximum" and the "splitting of the net square wave voltammetric peak" methods, values of (0.386±0.003) V, (0.46±0.04), and 2.7×10(2)s(-1) were calculated for the formal potential, the anodic transfer coefficient, and the formal rate constant, respectively, of the butein overall surface redox process in pH4.00 citrate buffer solutions. These results will be then used to study the interaction of butein, and other flavonoids with the deoxyribonucleic acid, in order to better understand the potential therapeutic applications of these compounds. Copyright © 2013 Elsevier B.V. All rights reserved.

  17. Direct chronopotentiometric analysis of riboflavin using a glassy carbon vessel as the working electrode

    Directory of Open Access Journals (Sweden)

    Brezo Tanja Ž.

    2016-01-01

    Full Text Available A new method for the determination of riboflavin (vitamin B2 was developed based on chronopotentiometry with a glassy carbon process vessel macroelectrode. The method optimisation included investigation of the most important experimental parameters: type and concentration of the supporting electrolyte, initial potential, reduction current, and the working electrode surface area. The reduction signal of riboflavin appeared at about -0.12 V vs. Ag/AgCl (3.5 mol/dm3 KCl electrode in 0.025 mol/dm3 HCl as the supporting electrolyte. A linear response was obtained in the the range of 0.05-4 mg/dm3. The limit of detection and limit of quantitation were 0.018 mg/dm3 and 0.054 mg/dm3, respectively. Due to the use of specific working electrode, a significant enhancement of the method relative sensitivity of about 10 times was achieved. The accuracy of the defined method was confirmed by HPLC analyses. The developed method was successfully applied for the quantitation of riboflavin in various pharmaceutical multivitamin preparations. [Projekat Ministarstva nauke Republike Srbije, br. III 46009

  18. First-wall and blanket engineering development for magnetic-fusion reactors

    International Nuclear Information System (INIS)

    Baker, C.; Herman, H.; Maroni, V.; Turner, L.; Clemmer, R.; Finn, P.; Johnson, C.; Abdou, M.

    1981-01-01

    A number of programs in the USA concerned with materials and engineering development of the first wall and breeder blanket systems for magnetic-fusion power reactors are described. Argonne National Laboratory has the lead or coordinating role, with many major elements of the research and engineering tests carried out by a number of organizations including industry and other national laboratories

  19. Development of high pressure magnetic force drive seal for commercial purpose

    International Nuclear Information System (INIS)

    Choi, Jong Hyeun; Hwang, S. T.; Choi, Y. D.; Kwon, S. W.; Kim, B. H.; Eo, H.; Lee, K. H.; Kim, J. K.; Jun, S. W.

    1999-12-01

    The purpose of this research is to develop and commercialize the magnetic seal which is used as a axis-sealing or connecting apparatus in the rotating machines where the liquid should not be leaked, instead of the existing mechanical seal. The developed magnetic seal will be applied in the rotating machine such as agitators and so on. In present, four institutes including Machinery Institute have purchased and using the agitators which applied the developed seal and have a good reputation. The existing mechanical seals a lot of which are used in the industry, has a complex structure, short-lifetime. And also, they are expensive and not leak-free. On the other hand, the developed magnetic seals have simple structure, low-cost, long-lifetime, and no-leakage. So these seals can be used most appropriately in the facilities which deal with dangerous and anti-environmental materials. And technical and economical effects of the magnetics seals will be expected. (author)

  20. Recent developments in cabling technology used to manufacture superconducting accelerator magnets

    Energy Technology Data Exchange (ETDEWEB)

    Royet, J.; Scanlan, R.M.

    1993-09-20

    The cable is the heart of superconducting accelerator magnets. Since the initial development of the Rutherford cable, more than twenty years ago, many improvements in manufacturing techniques have increased the current carrying capacity. An experimental cabling machine was designed and constructed at LBL in 1984.

  1. Electrochemical sensor based on magnetic molecularly imprinted nanoparticles modified magnetic electrode for determination of Hb.

    Science.gov (United States)

    Sun, Binghua; Ni, Xinjiong; Cao, Yuhua; Cao, Guangqun

    2017-05-15

    A fast and selective electrochemical sensor for determination of hemoglobin (Hb) was developed based on magnetic molecularly imprinted nanoparticles modified on the magnetic glassy carbon electrode. The nanoparticles Fe 3 O 4 @SiO 2 with a magnetic core and a molecularly imprinted shell had regular structures and good monodispersity. Hb could be determined directly by electrochemical oxidization with the modified electrode. A magnetic field increased electrochemical response to Hb by two times. Imprinting Hb on the surface of Fe 3 O 4 @SiO 2 shortened the response time within 7min. Under optimum conditions, the imprinting factor toward the non-imprinted sensor was 2.8, and the separation factor of Hb to horseradish peroxidase was 2.6. The oxidation peak current had a linear relationship with Hb concentration ranged from 0.005mg/ml to 0.1mg/ml with a detection limit (S/N =3) of 0.0010mg/ml. The sensors were successfully applied to analysis of Hb in whole blood samples with recoveries between 95.7% and 105%. Copyright © 2016 Elsevier B.V. All rights reserved.

  2. MR measurement of alloy magnetic susceptibility: towards developing tissue-susceptibility matched metals.

    Science.gov (United States)

    Astary, Garrett W; Peprah, Marcus K; Fisher, Charles R; Stewart, Rachel L; Carney, Paul R; Sarntinoranont, Malisa; Meisel, Mark W; Manuel, Michele V; Mareci, Thomas H

    2013-08-01

    Magnetic resonance imaging (MRI) can be used to relate structure to function mapped with high-temporal resolution electrophysiological recordings using metal electrodes. Additionally, MRI may be used to guide the placement of electrodes or conductive cannula in the brain. However, the magnetic susceptibility mismatch between implanted metals and surrounding brain tissue can severely distort MR images and spectra, particularly in high magnetic fields. In this study, we present a modified MR method of characterizing the magnetic susceptibility of materials that can be used to develop biocompatible, metal alloys that match the susceptibility of host tissue in order to eliminate MR distortions proximal to the implant. This method was applied at 4.7T and 11.1T to measure the susceptibility of a model solid-solution alloy of Cu and Sn, which is inexpensive but not biocompatible. MR-derived relative susceptibility values of four different compositions of Cu-Sn alloy deviated by less than 3.1% from SQUID magnetometry absolute susceptibility measurements performed up to 7T. These results demonstrate that the magnetic susceptibility varies linearly with atomic percentage in these solid-solution alloys, but are not simply the weighted average of Cu and Sn magnetic susceptibilities. Therefore susceptibility measurements are necessary when developing susceptibility-matched, solid-solution alloys for the elimination of susceptibility artifacts in MR. This MR method does not require any specialized equipment and is free of geometrical constraints, such as sample shape requirements associated with SQUID magnetometry, so the method can be used at all stages of fabrication to guide the development of a susceptibility matched, biocompatible device. Copyright © 2013 Elsevier Inc. All rights reserved.

  3. Development and application of measurement techniques for evaluating localised magnetic properties in electrical steel

    Science.gov (United States)

    Lewis, N. J.; Anderson, P. I.; Gao, Y.; Robinson, F.

    2018-04-01

    This paper reports the development of a measurement probe which couples local flux density measurements obtained using the needle probe method with the local magnetising field attained via a Hall effect sensor. This determines the variation in magnetic properties including power loss and permeability at increasing distances from the punched edge of 2.4% and 3.2% Si non-oriented electrical steel sample. Improvements in the characterisation of the magnetic properties of electrical steels would aid in optimising the efficiency in the design of electric machines.

  4. Program for development of toroidal superconducting magnets for fusion research, May 1975

    International Nuclear Information System (INIS)

    Long, H.M.; Lubell, M.S.

    1975-11-01

    The objective of this program is a tested magnet design which demonstrates the suitability and reliability needed to qualify toroidal superconducting magnets for fusion research devices in a time compatible with the D-T burning experiments time frame. The overall applied development program including tasks, manpower, and cost estimates is detailed here, but for the full toroidal system only the cost and time frame are outlined to show compatibility with the present program. The details of the full toroidal system fall under major device fabrication and will be included in a subsequent document

  5. Development of a magnetic system for the treatment of Helicobacter pylori infections

    International Nuclear Information System (INIS)

    Silva, Erica L.; Carvalho, Juliana F.; Pontes, Thales R.F.; Oliveira, Elquio E.; Francelino, Barbara L.; Medeiros, Aldo C.; Egito, E. Socrates T. do; Araujo, Jose H.; Carrico, Artur S.

    2009-01-01

    We report a study to develop a magnetic system for local delivery of amoxicillin. Magnetite microparticles produced by coprecipitation were coated with a solution of amoxicillin and Eudragit S100 by spray drying. Scanning electron microscopy, optical microscopy, X-ray powder diffraction and vibrating sample magnetometry revealed that the particles were superparamagnetic, with an average diameter of 17.2 μm, and an initial susceptibility controllable by the magnetite content in the suspension feeding the sprayer. Our results suggest a possible way to treat Helicobacter pylori infections, using an oral drug delivery system, and open prospects to coat magnetic microparticles by spray drying for biomedical applications.

  6. Development of a magnetic system for the treatment of Helicobacter pylori infections

    Science.gov (United States)

    Silva, Érica L.; Carvalho, Juliana F.; Pontes, Thales R. F.; Oliveira, Elquio E.; Francelino, Bárbara L.; Medeiros, Aldo C.; do Egito, E. Sócrates T.; Araujo, José H.; Carriço, Artur S.

    2009-05-01

    We report a study to develop a magnetic system for local delivery of amoxicillin. Magnetite microparticles produced by coprecipitation were coated with a solution of amoxicillin and Eudragit ®S100 by spray drying. Scanning electron microscopy, optical microscopy, X-ray powder diffraction and vibrating sample magnetometry revealed that the particles were superparamagnetic, with an average diameter of 17.2 μm, and an initial susceptibility controllable by the magnetite content in the suspension feeding the sprayer. Our results suggest a possible way to treat Helicobacter pylori infections, using an oral drug delivery system, and open prospects to coat magnetic microparticles by spray drying for biomedical applications.

  7. Development of a magnetic system for the treatment of Helicobacter pylori infections

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Erica L.; Carvalho, Juliana F.; Pontes, Thales R.F.; Oliveira, Elquio E. [Departamento de Farmacia, Universidade Federal do Rio Grande do Norte, Rua Gal Gustavo Cordeiro de Farias s.n, Petropolis, 59010-180 Natal-RN (Brazil); Francelino, Barbara L.; Medeiros, Aldo C. [Departamento de Medicina, Universidade Federal do Rio Grande do Norte, Rua Gal Gustavo Cordeiro de Farias s.n, Petropolis, 59010-180 Natal-RN (Brazil); Egito, E. Socrates T. do [Departamento de Farmacia, Universidade Federal do Rio Grande do Norte, Rua Gal Gustavo Cordeiro de Farias s.n, Petropolis, 59010-180 Natal-RN (Brazil); Araujo, Jose H. [Departamento de Fisica Teorica e Experimental, Universidade Federal do Rio Grande do Norte, Campus Universitario, 59078-970 Natal-RN (Brazil); Carrico, Artur S. [Departamento de Fisica Teorica e Experimental, Universidade Federal do Rio Grande do Norte, Campus Universitario, 59078-970 Natal-RN (Brazil)], E-mail: ascarrico@dfte.ufrn.br

    2009-05-15

    We report a study to develop a magnetic system for local delivery of amoxicillin. Magnetite microparticles produced by coprecipitation were coated with a solution of amoxicillin and Eudragit S100 by spray drying. Scanning electron microscopy, optical microscopy, X-ray powder diffraction and vibrating sample magnetometry revealed that the particles were superparamagnetic, with an average diameter of 17.2 {mu}m, and an initial susceptibility controllable by the magnetite content in the suspension feeding the sprayer. Our results suggest a possible way to treat Helicobacter pylori infections, using an oral drug delivery system, and open prospects to coat magnetic microparticles by spray drying for biomedical applications.

  8. Development of a phosphating process for corrosion protection in NdFeB magnets

    International Nuclear Information System (INIS)

    Silva, Adonis Marcelo Saliba

    2001-01-01

    NdFeB magnets are important materials, which produce better energy efficiency in electrical devices, but they are rather vulnerable to corrosion. In this study, a phosphating treatment for protection against corrosion of NdFeB magnets has been investigated. Phosphating is generally used as a pretreatment in the application of protective coatings. This treatment increases the corrosion assistance in defective areas of the coating as well as improves the adhesion between coating and substrate. A commercial NdFeB magnet produced by powder metallurgy has been used and the effect of the following parameters on phosphating was studied: time of phosphating; pH of phosphating solution; anodic polarization and molybdate addition to the phosphating solution. The results showed a significant increase in the corrosion resistance of magnets phosphated in a solution concentrated between 10-20 g/L NaH 2 PO 4 , pH in the range of 3 to 4.6, acidulated preferably with H 3 PO 4 at room temperature (20±1) deg C. Conversion coatings formed at solutions of pH 3.8 showed better corrosion resistance. Phosphating times longer than 4 hours increased the magnet corrosion resistance 10 to 20 times. This resistance improves with higher immersion times. Anodic polarization of the magnet in the range 200-400 mV SCE accelerated phosphating. Results indicated that molybdate interacts preferentially with Nd rich phase of the magnet. In addition to the newly developed technology in this work for NdFeB corrosion protection, two methodologies have been introduced to facilitate electrochemical analyses: selection of samples of similar electrochemical behavior, based on the current density after 200s of constant anodic polarization; and evaluation of the corrosion protection provided by conversion coatings by monitoring of gas evolution during corrosion in acid solution. (author)

  9. [Preparation of OMC-Au/L-Lysine/Au modified glassy carbon electrode and the study on its detection response to hydroquinone and catechol].

    Science.gov (United States)

    Zhou, Yao-Yu; Tang, Lin; Li, Zhen; Liu, Yuan-Yuan; Yang, Gui-De; Wu, Meng-Shi; Lei, Xiao-Xia; Zheng, Guang-Ming

    2013-03-01

    Ordered mesoporous carbon-Au nanoparticles (OMC-Au) nanocomposites were synthesized by a one-step chemical reduction route, and an OMC-Au/L-Lysine/Au composite film-modified glassy carbon electrode (GCE) was constructed. The microstructure of OMC and OMC-Au/L-Lysine/Au composite films were characterized by SEM, and the preparation process of OMC-Au/L-Lysine/Au modified glassy carbon electrode was investigated using cyclic voltammetry and electrochemical impedance spectroscopy. The electrocatalytic oxidation of hydroquinone and catechol on the modified electrode was discussed by differential pulse voltammetry in this study, and a sensor for separate determination of hydroquinone and catechol based on OMC-Au/L-Lysine/Au modified glassy carbon electrode was developed. Under the optimal conditions, the cathodic peak current was linearly related to hydroquinone concentration over ranges from 1.0 x 10(-6) mol x L(-1) to 8.0 x 10(-4) mol x L(-1) with a detection limit of 3.0 x 10(-7) mol x L(-1), and linearly related to catechol concentration from 1.0 x 10(-7) mol x L(-1) to 8.0 x 10(-5) mol x L(-1) with a detection limit of 8.0 x 10(-7) mol x L(-1).

  10. Diffusion coefficients of tracers in glassy polymer systems prepared by gamma radiolysis

    International Nuclear Information System (INIS)

    Tonge, M.P.; Gilbert, R.G.

    1996-01-01

    Diffusion-controlled reactions are common in free radical polymerisation reactions, especially in glassy polymer matrices. Such reactions commonly have an important influence on the polymerisation process and final polymer properties. For example, the dominant growth-stopping event (bimolecular termination) is generally diffusion-controlled. In glassy polymer systems, where molecular mobility is very low, the chain growth mechanism (propagation) may become diffusion-controlled. At present, the mechanism for propagation in glassy polymers is poorly understood, but it is expected by the Smoluchowski expression applied to propagation to depend strongly on the diffusion coefficient of monomer. The objective of this study is to measure reliable diffusion coefficients of small tracer molecules in glassy polymers, and compare these with propagation rate coefficients in similar systems, by the prediction above. Samples were initially prepared in a sealed sampled cell containing monomer, inert diluent, and tracer dye. After irradiation for several days, complete conversion of monomer to polymer can be obtained. The diffusion coefficients for two tracer dyes have been measured as a function of weight fraction polymer glassy poly(methyl methacrylate) samples

  11. Permanent magnet Hall Thrusters development and applications on future brazilian space missions

    Science.gov (United States)

    Ferreira, Jose Leonardo; Martins, Alexandre A.; Miranda, Rodrigo; Schelling, Adriane; de Souza Alves, Lais; Gonçalves Costa, Ernesto; de Oliveira Coelho Junior, Helbert; Castelo Branco, Artur; de Oliveira Lopes, Felipe Nathan

    2015-10-01

    The Plasma Physics Laboratory (PPLUnB) has been developing a Permanent Magnet Hall Thruster (PHALL) for the Space Research Program for Universities (UNIESPAÇO), part of the Brazilian Space Activities Program (PNAE) since 2004. The PHALL project consists on a plasma source design, construction and characterization of the Hall type that will function as a plasma propulsion engine and characterized by several plasma diagnostics sensors. PHALL is based on a plasma source in which a Hall current is generated inside a cylindrical annular channel with an axial electric field produced by a ring anode and a radial magnetic field produced by permanent magnets. In this work it is shown a brief description of the plasma propulsion engine, its diagnostics instrumentation and possible applications of PHALL on orbit transfer maneuvering for future Brazilian geostationary satellite space missions.

  12. Development of Plasma Fluid Model for a Microwave Rocket Supported by a Magnetic Field

    Science.gov (United States)

    Takahashi, Masayuki

    2017-10-01

    A uid model of plasma transport is developed to reproduce a plasma pattern induced by microwave irradiation when an external magnetic field is applied to the breakdown volume. Transport coefficients in the uid model are evaluated using a fully kinetic simulation under a magnetic field to maintain consistency of electron transport between the particle and uid models. The electron-density profile and propagation speed of the ionization front obtained by the uid model agree with those of the particle model. Multidimensional or longer time-scale simulations can be conducted using the uid model in the case of the application of an external magnetic field, with the simulation reducing computational cost compared to the fully kinetic model.

  13. Further Development of the Sextupole Dipole Corrector (MSCB) Magnet for the LHC

    CERN Document Server

    Ang, Z; Bajko, M; Bottura, L; Coxill, D; Giloux, C; Ijspeert, Albert; Karppinen, M; Landgrebe, D; Walckiers, L

    2000-01-01

    Combined sextupole-dipole corrector magnets (MSCB) will be mounted in each half cell of the new Large Hadron Collider (LHC) being built at CERN. The dipole part, used for particle orbit corrections, will be powered individually and is designed for low current, originally 30 A but now 55 A. The sextupole part, used for chromaticity corrections, is connected via cold busbars in families of 12 or 13 magnets and is powered with 550 A. Several versions of this corrector magnet were tested as model magnets in order to develop the final design for the series. In the first design the coils are nested, with the dipole coil wound around the sextupole coil to obtain as short a magnet as possible, accepting the slight cross-talk between the coils due to persistent currents, and increased saturation effects. The design has evolved and an alternative design, in which the dipole and sextupole coils are separated, is now favored. Tests at 4.5 K and at 1.9 K were conducted to determine the training behavior, the field qualit...

  14. Development of a compact 30 T magnetic field system for OMEGA

    Science.gov (United States)

    Fiksel, G.; Backhus, R.; McNally, P.; Viges, E.; Villalta, M.; Jacobs-Perkins, D.; Betti, R.

    2017-10-01

    Aiming at conducting studies of magnetized high-energy density plasmas in a high magnetic field, we are developing a compact system capable of creating a pulsed magnetic field of about 30T in a volume of several cubic centimeters. The system prototype will be tested at the University of Michigan and will be adopted afterwards for use at the OMEGA facility of the Laboratory for Laser Energetics (LLE) of the University of Rochester, NY. The system consists of a pulsed power supply situated outside of the Omega vacuum chamber and a magnetic coil inserted into the chamber with a diagnostic inserter. The power supply is based on a 50 μF/20kV storage capacitor and is capable of driving a pulse of current of up to 50kA through the coil. The power supply is connected with the coil via a low-inductive chain of power cables and a strip transmission line. The system electrical, magnetic, and thermal analysis will be presented along with the results of initial testing. This work is supported in part through a DOE-OFES award DE-SC0016258 and a University of Michigan research Grant U051442.

  15. Development of cryogenic undulators with PrFeB magnets at SOLEIL

    Energy Technology Data Exchange (ETDEWEB)

    Valléau, M., E-mail: valleau@synchrotron-soleil.fr; Benabderrahmane, C.; Briquez, F.; Berteaud, P.; Tavakoli, K.; Zerbib, D.; Chapuis, L.; Marteau, F.; Marcouillé, O.; El Ajjouri, T.; Vétéran, J.; Sharma, G.; Tilmont, M.; Castro, J. Da Silva; N’Guyen, M.-H.; Béchu, N.; Rommeluère, P.; Louvet, M.; Nadji, A.; Herbeaux, C. [Synchrotron-Soleil, L’Orme des Merisisers, 91192 BP 34, Gif Sur Yvette (France); and others

    2016-07-27

    Short period high field undulators are of interest for X-ray brilliance enhancement in synchrotron radiation applications and for compact Free Electron Lasers. Cryogenic in-vacuum undulators [1] are one of the possible solutions. At SOLEIL, PrFeB magnets were directly chosen, even if still under development at that time. Indeed, they enable to avoid the spin transition reorientation phenomenon which occurs with NdFeB magnets [2] and the magnets can be cooled down directly at 77 K. The first selected grade CR53 from Hitachi presents a remanence of 1.35 T at 293 K and 1.57 T at 77 K, with a coercivity of 1355 kA/m at 293 K and 6000 kA/m at 77 K. A 2 m long cryogenic undulator of period 18 mm was first built in-house, with a specific Hall probe bench directly installed in the final vacuum chamber. This first cryogenic undulator has been in operation on the storage ring for 4 years [3]. A second U18 cryo-ready undulator using a slightly different magnet grade with a higher coercivity and modules with magnets surrounded by two half poles for easier magnetic optimization is under construction. A third 3 m long cryo-ready undulator U15 with a period of 15 mm is under development. It will be first used for the LUNEX5 FEL [4, 5] project (COXINEL demonstration of FEL amplification with a laser wakefield acceleration [6]). The measurement bench will include a correction of the Hall probe position and angle, the field integrals will be measured with a stretched wire.

  16. Glassy behavior of diluted Cu-Zn ferrites

    Science.gov (United States)

    Akhter, Shahida; Hakim, M. A.; Hoque, S. M.; Mathieu, R.; Nordblad, P.

    2018-04-01

    The magnetic behavior of Zn substituted Cu-Zn spinel ferrites having chemical formula Cu1-xZnxFe2O4 (x = 0.7, 0.8, 0.9 and 1.0) has been studied by SQUID magnetometry, by means of magnetic hysteresis, field-cooled (FC) and zero-field-cooled (ZFC) magnetization, memory effect and low field ac susceptibility measurements. These measurements suggest that the ferrimagnetic phase of the x ≤ 0.8 samples is gradually turned into a spin glass (x ≥ 0.9). The compound with x = 0.9 exhibits the typical dynamical behavior of spin glasses, with indication of aging, rejuvenation and memory effects. The evolution of the magnetic properties of Cu-Zn spinel ferrites with substitution of Zn for Cu is discussed.

  17. Development and optimization of resonators and ways of detection in nuclear magnetic resonance

    International Nuclear Information System (INIS)

    Behr, Volker Christian

    2008-01-01

    Aims of this dissertation were to construct resonators for very high flux densities and to develop appropriate probe bases. These were successfully realized with numerous resonators as well as two kinds of probe bases. Furthermore, new techniques and methods of signal detection were developed and evaluated. Magnetic flux guides, which were unknown in NMR up until now were used for the first time for both transmission and reception. Moreover, an optical acquisition technique based on the Faraday effect was realized and evaluated

  18. Alterations of the Temporomandibular Joint on Magnetic Resonance Imaging according to Growth and Development in Schoolchildren

    OpenAIRE

    Tanaka, Tatsurou; Konoo, Tetsuro; Habu, Manabu; Oda, Masafumi; Kito, Shinji; Kodama, Masaaki; Kokuryo, Shinya; Wakasugi-Sato, Nao; Matsumoto-Takeda, Shinobu; Nishida, Ikuko; Morikawa, Kazumasa; Saeki, Katsura; Maki, Kenshi; Tominaga, Kazuhiro; Masumi, Shin-ichi

    2012-01-01

    The paper explains the alterations of the temporomandibular joint (TMJ) visualized by magnetic resonance imaging (MRI) according to the growth and development of schoolchildren. Appearance and disappearance of a ?double contour-like structure? (DCLS) of the mandibular condyle on MRI according to the growth and development of schoolchildren were demonstrated. In addition, possible constituents of DCLS and the significance of detection of DCLS on MRI were also speculated. The relationship betwe...

  19. Development of magnetic resonance imaging based detection methods for beta amyloids via sialic acid-functionalized magnetic nanoparticles

    Science.gov (United States)

    Kouyoumdjian, Hovig

    The development of a non-invasive method for the detection of Alzheimer's disease is of high current interest, which can be critical in early diagnosis and in guiding preventive treatment of the disease. The aggregates of beta amyloids are a pathological hallmark of Alzheimer's disease. Carbohydrates such as sialic acid terminated gangliosides have been shown to play significant roles in initiation of amyloid aggregation. Herein, we report a biomimetic approach using sialic acid coated iron oxide superparamagnetic nanoparticles for in vitro detection in addition to the assessment of the in vivo mouse-BBB (Blood brain barrier) crossing of the BSA (bovine serum albumin)-modified ones. The sialic acid functionalized dextran nanoparticles were shown to bind with beta amyloids through several techniques including ELISA (enzyme linked immunosorbent assay), MRI (magnetic resonance imaging), TEM (transmission electron microscopy), gel electrophoresis and tyrosine fluorescence assay. The superparamagnetic nature of the nanoparticles allowed easy detection of the beta amyloids in mouse brains in both in vitro and ex vivo model by magnetic resonance imaging. Furthermore, the sialic acid nanoparticles greatly reduced beta amyloid induced cytotoxicity to SH-SY5Y neuroblastoma cells, highlighting the potential of the glyconanoparticles for detection and imaging of beta amyloids. Sialic acid functionalized BSA (bovine serum albumin) nanoparticles also showed significant binding to beta amyloids, through ELISA and ex vivo mouse brain MRI experiments. Alternatively, the BBB crossing was demonstrated by several techniques such as confocal microscopy, endocytosis, exocytosis assays and were affirmed by nanoparticles transcytosis assays through bEnd.3 endothelial cells. Finally, the BBB crossing was confirmed by analyzing the MRI signal of nanoparticle-injected CD-1 mice.

  20. The Enhanced Photo-Electrochemical Detection of Uric Acid on Au Nanoparticles Modified Glassy Carbon Electrode

    Science.gov (United States)

    Shi, Yuting; Wang, Jin; Li, Shumin; Yan, Bo; Xu, Hui; Zhang, Ke; Du, Yukou

    2017-07-01

    In this work, a sensitive and novel method for determining uric acid (UA) has been developed, in which the glassy carbon electrode (GCE) was modified with electrodeposition Au nanoparticles and used to monitor the concentration of UA with the assistant of visible light illumination. The morphology of the Au nanoparticles deposited on GCE surface were characterized by scanning electron microscope (SEM) and the nanoparticles were found to be well-dispersed spheres with the average diameter approaching 26.1 nm. A series of cyclic voltammetry (CV) and differential pulse voltammetry (DPV) measurements have revealed that the introduction of visible light can greatly enhance both the strength and stability of response current due to the surface plasmon resonance (SPR). Specifically, the DPV showed a linear relationship between peak current and UA concentration in the range of 2.8 to 57.5 μM with the equation of I pa (μA) = 0.0121 c UA (μM) + 0.3122 ( R 2 = 0.9987). Herein, the visible light illuminated Au/GCE possesses a potential to be a sensitive electrochemical sensor in the future.

  1. Square Wave Voltammetric Determination of 2-Thiouracil in Pharmaceuticals and Real Samples Using Glassy Carbon Electrode

    Directory of Open Access Journals (Sweden)

    Naveen M. Gokavi

    2013-01-01

    Full Text Available A simple and rapid method was developed using cyclic and square wave voltammetric techniques for the determination of trace-level sulfur containing compound, 2-thiouracil, at a glassy carbon electrode. 2-thiouracil produced two anodic peaks at 0.334 V and 1.421 V and a cathodic peak at −0.534 V. The square wave voltammetry of 2-thiouracil gave a good linear response in the range of 1–20 μM with a detection limit of 0.16 μM and quantification limit of 0.53 μM (0.0679 μg/g, which is in good agreement as per IUPAC definition of trace component analysis (100 μg/g. The obtained recoveries range from 98.10% to 102.1%. The proposed method was used successfully for its quantitative determination in pharmaceutical formulations and urine as real samples.

  2. Thermodynamic parameters of bonds in glassy materials from viscosity-temperature relationships

    International Nuclear Information System (INIS)

    Ojovan, Michael I; Travis, Karl P; Hand, Russell J

    2007-01-01

    Doremus's model of viscosity assumes that viscous flow in amorphous materials is mediated by broken bonds (configurons). The resulting equation contains four coefficients, which are directly related to the entropies and enthalpies of formation and motion of the configurons. Thus by fitting this viscosity equation to experimental viscosity data these enthalpy and entropy terms can be obtained. The non-linear nature of the equation obtained means that the fitting process is non-trivial. A genetic algorithm based approach has been developed to fit the equation to experimental viscosity data for a number of glassy materials, including SiO 2 , GeO 2 , B 2 O 3 , anorthite, diopside, xNa 2 O-(1-x)SiO 2 , xPbO-(1-x)SiO 2 , soda-lime-silica glasses, salol, and α-phenyl-o-cresol. Excellent fits of the equation to the viscosity data were obtained over the entire temperature range. The fitting parameters were used to quantitatively determine the enthalpies and entropies of formation and motion of configurons in the analysed systems and the activation energies for flow at high and low temperatures as well as fragility ratios using the Doremus criterion for fragility. A direct anti-correlation between fragility ratio and configuron percolation threshold, which determines the glass transition temperature in the analysed materials, was found

  3. Biomedical Applications of Modified Carbon Glassy Electrode Sensor with Nanoparticles and Dendrimers

    Directory of Open Access Journals (Sweden)

    Solomon W. LEUNG

    2011-04-01

    Full Text Available We previously reported the development of a biosensor platform that is capable of measuring biometabolites and environmental sensitive species, such as peroxide and nitrate/nitrate, to concentrations in the order of ppb (parts per billion or lower. In this investigation, we modified our platform with dendrimers to enhance its performance. Zero and second generation of dendrimers were coated on the surface of a carbon glassy electrode which was then modified with l-glutamate dehydrogenase (GDH and α-keto glutarate. The resulting electrode was tested with ammonium solutions, concentrations ranged from 2 to 300 nM at pH 7.4; the results were satisfactory. Measurements at lower concentrations had better resolution than at higher concentrations and it is believed that the measurement limit can be lower than 2 nM. This biosensor platform was proven to be versatile and can be employed as a platform for ultrasensitive detecting devices in many biomedical and environmental applications.

  4. Structural Modifications And Mechanical Degradation Of Ion Irradiated Glassy Polymer Carbon

    Science.gov (United States)

    Abunaemeh, Malek; Seif, Mohamed; Elsamadicy, Abdalla; Muntele, Claudiu; Ila, Daryush

    2011-06-01

    The TRISO fuel has been used in some of the Generation IV nuclear reactor designs. It consists of a fuel kernel of UOx coated with several layers of materials with different functions. Pyrolytic carbon (PyC) is one of the materials in the layers. In this study we investigate the possibility of using Glassy Polymeric Carbon (GPC) as an alternative to PyC. GPC is used for artificial heart valves, heat-exchangers, and other high-tech products developed for the space and medical industries. This lightweight material can maintain dimensional and chemical stability in adverse environment and very high temperatures (up to 3000 °C). In this work, we are comparing the changes in physical and microstructure properties of GPC after exposure to irradiation fluence of 5 MeV Ag equivalent to a 1 displacement per atom (dpa) at samples prepared at 1000, 1500 and 2000 °C. The GPC material is manufactured and tested at the Center for Irradiation Materials (CIM) at Alabama A&M University. Transmission electron microscopy (TEM) and Raman spectroscopy were used for analysis.

  5. Pulse Laser Deposition Fabricating Gold Nanoclusters on a Glassy Carbon Surface for Nonenzymatic Glucose Sensing.

    Science.gov (United States)

    Shu, Honghui; Chang, Gang; Wang, Zhiqiang; Li, Pai; Zhang, Yuting; He, Yunbin

    2015-01-01

    A One-step technique for depositing gold nanoclusters (GNCs) onto the surface of a glassy carbon (GC) plate was developed by using pulse laser deposition (PLD) with appropriate process parameters. The method is simple and clean without using any templates, surfactants, or stabilizers. The experimental factors (pulse laser number and the pressure of inert gas (Ar)) that affect the morphology and structure of GNCs, and thus affect the electrocatalytic oxidation performance towards glucose were systematically investigated by means of transmission electron microscopy (TEM) and electrochemical methods (cyclic voltammograms (CV) and chronoamperometry methods). The GC electrode modified by GNCs exhibited a rapid response time (about 2 s), a broad linear range (0.1 to 20 mM), and good stability. The sensitivity was estimated to be 31.18 μA cm(-2) mM(-1) (vs. geometric area), which is higher than that of the Au bulk electrode. It has a good resistance to the common interfering species, such as ascorbic acid (AA), uric acid (UA) and 4-acetaminophen (AP). Therefore, this work has demonstrated a simple and effective sensing platform for the nonenzymatic detection of glucose, and can be used as a new material for a novel non-enzymatic glucose sensor.

  6. Mechanical properties of Fe-Ni-Cr-Si-B bulk glassy alloy

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Kee Ahn [School of Advanced Materials Engineering, Andong National University, Andong 760-749 (Korea, Republic of)]. E-mail: keeahn@andong.ac.kr; Kim, Yong Chan [New Metals Research Team, RIST, Pohang 790-330 (Korea, Republic of); Kim, Jung Han [Center for Advanced Aerospace materials, POSTECH, Pohang 790-784 (Korea, Republic of); Lee, Chong Soo [Center for Advanced Aerospace materials, POSTECH, Pohang 790-784 (Korea, Republic of); Namkung, Jung [New Metals Research Team, RIST, Pohang 790-330 (Korea, Republic of); Kim, Moon Chul [New Metals Research Team, RIST, Pohang 790-330 (Korea, Republic of)

    2007-03-25

    The mechanical properties and crystallization behavior of new Fe-Ni-Cr-Si-B-based bulk glassy alloys were investigated. The suitability of the continuous roll casting method for the production of bulk metallic glass (BMG) sheets in such alloy systems was also examined. BMG samples (Fe-Ni-Cr-Si-B, Fe-Ni-Zr-Cr-Si-B, Fe-Ni-Zr-Cr-W-Si-B) in amorphous strip, cylindrical, and sheet forms were prepared through melt spinning, copper mold casting, and twin roll strip casting, respectively. Fe-Ni-Cr-Si-B alloy exhibited compressive strength of up to 2.93 GPa and plastic strain of about 1.51%. On the other hand, the Fe-Ni-Zr-Cr-Si-B, composite-type bulk sample with diameter of 2.0 mm showed remarkable compressive plastic strain of about 4.03%. The addition of zirconium was found to enhance the homogeneous precipitation of nanocrystalline less than 7 nm and to develop a hybrid-composite microstructure with increasing sample thickness. Twin roll strip casting was successfully applied to the fabrication of sheets in Fe-Ni-Cr-Si-B-based BMGs. The combined characteristics of high mechanical properties and ease of microstructure control proved to be promising in terms of the future progress of structural bulk amorphous alloys.

  7. Development of the 1.2 T~1.5 T Permanent Magnetic Resonance Imaging Device and Its Application for Mouse Imaging

    Directory of Open Access Journals (Sweden)

    Guangxin Wang

    2015-01-01

    Full Text Available By improving the main magnet, gradient, and RF coils design technology, manufacturing methods, and inventing new magnetic resonance imaging (MRI special alloy, a cost-effective and small animal specific permanent magnet-type three-dimensional magnetic resonance imager was developed. The main magnetic field strength of magnetic resonance imager with independent intellectual property rights is 1.2~1.5 T. To demonstrate its effectiveness and validate the mouse imaging experiments in different directions, we compared the images obtained by small animal specific permanent magnet-type three-dimensional magnetic resonance imager with that obtained by using superconductor magnetic resonance imager for clinical diagnosis.

  8. Electrochemical functionalization of glassy carbon electrode by reduction of diazonium cations in protic ionic liquid

    International Nuclear Information System (INIS)

    Shul, Galyna; Ruiz, Carlos Alberto Castro; Rochefort, Dominic; Brooksby, Paula A.; Bélanger, Daniel

    2013-01-01

    Protic ionic liquid based on 2-methoxypyridine and trifluoroacetic acid was used as electrolyte for the functionalization of a glassy carbon electrode surface by electrochemical reduction of in situ generated 4-chlorobenzene diazonium and 4-nitrobenzene diazonium cations. The diazonium cations were synthesized in an electrochemical cell by reaction of the corresponding amines with NaNO 2 dissolved in protic ionic liquid. The resulting electrografted organic layers exhibit similar properties to those layers obtained by the derivatization from isolated diazonium salts dissolved in protic ionic liquid. Functionalized glassy carbon electrode surfaces were characterized by cyclic voltammetry, Fourier transform infrared and X-ray photoelectron spectroscopies. Atomic force microscopy thickness measurements revealed that, in our experimental conditions, the use of protic ionic liquid led to the formation of film with a thickness of about 1.5 nm. It is also demonstrated that the nitrobenzene chemisorbed on glassy carbon electrode or dissolved in protic ionic liquid undergoes electrochemical conversion to hydroxyaminobenzene

  9. 1998 Annual Study Report. Research and development of power storage by high-temperature superconducting flywheels (research and development of permanent magnet); 1998 nendo seika hokokusho. Koon chodendo flywheel denryoku chozo kenkyu kaihatsu (eikyu jishaku no kenkyu kaihatsu)

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-05-01

    The permanent magnets have been investigated and developed, for eventual commercialization of a 10 MWh power storage system by high-temperature superconducting flywheel. The permanent magnet rotors have been already developed in the previous years using a praseodymium-based magnet (Pr magnet) and neodymium-based sintered magnet (Nd sintered magnet), and the target rotational speed of 30,000 rpm has been attained. For development of the magnetic circuit to produce a stronger and smoother magnetic field, magnetic flux density of the Nd sintered magnet is measured. It shows a lower magnetic flux irregularity than the Pd magnet, but there is still room for further improvement. For development of large-size permanent magnet fabrication techniques, it is confirmed that the large-size Nd sintered magnet can be easily magnetized by partial magnetizing, as is the case with the Pr magnet. In this year, the irregular magnetic flux is three-dimensionally simulated, based on the results obtained in the previous years, to find that the simulated results are in good agreement with the observed ones. The measures to solve the problems are also investigated. It is also confirmed that the large-size ring magnet can be easily magnetized by partial magnetization. (NEDO)

  10. Development of Nuclear Magnetic Resonance Imaging/spectroscopy for improved petroleum recovery. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Barrufet, M.A.; Flumerfelt, F.W.; Walsh, M.P.; Watson, A.T.

    1994-04-01

    The overall objectives of this program are to develop and apply Nuclear Magnetic Resonance Imaging (NMRI) and CT X-Ray Scanning methods for determining rock, fluid, and petrophysical properties and for fundamental studies of multiphase flow behavior in porous media. Specific objectives are divided into four subtasks: (1) development of NMRI and CT scanning for the determination of rock-fluid and petrophysical properties; (2) development of NMRI and CT scanning for characterizing conventional multiphase displacement processes; (3) development of NMR and CT scanning for characterizing dispersed phase processes; and (4) miscible displacement studies.

  11. Strongly magnetic soil developed on a non-magnetic rock basement: A case study from NW Bulgaria

    Czech Academy of Sciences Publication Activity Database

    Grison, Hana; Petrovský, Eduard; Jordanova, N.; Kapička, Aleš

    2011-01-01

    Roč. 55, č. 4 (2011), s. 697-716 ISSN 0039-3169 R&D Projects: GA AV ČR(CZ) KJB300120604 Institutional research plan: CEZ:AV0Z30120515 Keywords : magnetic susceptibility * magnetite * soil * pollution * climate * limestone Subject RIV: DE - Earth Magnetism, Geodesy, Geography Impact factor: 0.700, year: 2011

  12. Development of a biocompatible magnetic nanofluid by incorporating SPIONs in Amazonian oils

    Science.gov (United States)

    Gaspar, André S.; Wagner, Friedrich E.; Amaral, Vítor S.; Costa Lima, Sofia A.; Khomchenko, Vladimir A.; Santos, Judes G.; Costa, Benilde F. O.; Durães, Luísa

    2017-02-01

    Higher quality magnetic nanoparticles are needed for use as magnetic nanoprobe in medical imaging techniques and cancer therapy. Moreover, the phytochemistry benefits of some Amazonian essential oils have sparked great interest for medical treatments. In this work, a magnetic nanoprobe was developed, allying the biocompatibility and superparamagnetism of iron oxide nanoparticles (SPIONs) with benefits associated with Amazonian oils from Copaiba and Andiroba trees. SPIONs were obtained by two thermal decomposition procedures and different amounts of precursors (iron acetylacetonates). Their characterization was accomplished by Fourier transform infrared spectroscopy, thermogravimetric analysis, transmission electron microscopy (TEM), X-ray diffraction (XRD), Mössbauer spectroscopy and magnetization. The obtained nanoparticles composition and magnetic properties were not affected by the relative proportion of iron(II) and iron(III) in the precursor system. However, when changing the reducing and stabilizing agents the coating layer shows different compositions/relative weight - the more promising SPIONs have a coating mainly composed by oleylamine and an iron oxide:coating wt% ratio of 55:45. Nanoparticles size distributions were very narrow and centred in the average size of 6-7 nm. Cellular assays confirmed the biocompatibility of SPIONs and their effective internalization in human colon cancer cells. Mössbauer/XRD results indicated maghemite as their main iron oxide phase, but traces of magnetite proved to be present. Magnetization saturations of 57 emu/g at 5 K and 42 emu/g at 300 K were achieved. With incorporation of SPIONs into Copaiba and Andiroba essential oils, these values show a 4-fold decrease, but the supermagnetic behaviour is preserved providing the effective formation of a nanofluid.

  13. Electrochemical Determination of Caffeine Content in Ethiopian Coffee Samples Using Lignin Modified Glassy Carbon Electrode

    OpenAIRE

    Amare, Meareg; Aklog, Senait

    2017-01-01

    Lignin film was deposited at the surface of glassy carbon electrode potentiostatically. In contrast to the unmodified glassy carbon electrode, an oxidative peak with an improved current and overpotential for caffeine at modified electrode showed catalytic activity of the modifier towards oxidation of caffeine. Linear dependence of peak current on caffeine concentration in the range 6 ? 10?6 to 100 ? 10?6?mol?L?1 with determination coefficient and method detection limit (LoD = 3?s/slope) of 0....

  14. Elastic properties of aspirin in its crystalline and glassy phases studied by micro-Brillouin scattering

    Science.gov (United States)

    Ko, Jae-Hyeon; Lee, Kwang-Sei; Ike, Yuji; Kojima, Seiji

    2008-11-01

    The acoustic waves propagating along the direction perpendicular to the (1 0 0) cleavage plane of aspirin crystal were investigated using micro-Brillouin spectroscopy from which C11, C55 and C66 were obtained. The temperature dependence of the longitudinal acoustic waves could be explained by normal anharmonic lattice models, while the transverse acoustic waves showed an abnormal increase in the hypersonic attenuation at low temperatures indicating their coupling to local remnant dynamics. The sound velocity as well as the attenuation of the longitudinal acoustic waves of glassy aspirin showed a substantial change at ˜235 K confirming a transition from glassy to supercooled liquid state in vitreous aspirin.

  15. SUPERNOVA SHOCK-WAVE-INDUCED CO-FORMATION OF GLASSY CARBON AND NANODIAMOND

    Energy Technology Data Exchange (ETDEWEB)

    Stroud, Rhonda [Naval Research Laboratory, Washington, D.C.; Chisholm, Matthew F [ORNL; Heck, Phillipp [The Field Museum, Chicago, IL; Alexander, Conel [Carnegie Institution of Washington; Nittler, Larry [Carnegie Institution of Washington

    2011-01-01

    Nanodiamond (ND) was the first extrasolar dust phase to be identified in meteorites. However, the 2 nm average size of the NDs precludes isotopic analysis of individual particles, and thus their origin(s) remains controversial. Using electron microscopy with subnanometer resolution, we show that ND separates from the Allende and Murchison meteorites are actually a two-phase mixture of ND and glassy carbon. This phase mixture is likely the product of supernova shock-wave transformation of pre-formed organics in the interstellar medium (ISM). The glassy carbon ND mixture is also a plausible contributor to the 2175 extinction feature in the diffuse ISM.

  16. SUPERNOVA SHOCK-WAVE-INDUCED CO-FORMATION OF GLASSY CARBON AND NANODIAMOND

    International Nuclear Information System (INIS)

    Stroud, Rhonda M.; Chisholm, Matthew F.; Heck, Philipp R.; Alexander, Conel M. O'D.; Nittler, Larry R.

    2011-01-01

    Nanodiamond (ND) was the first extrasolar dust phase to be identified in meteorites. However, the 2 nm average size of the NDs precludes isotopic analysis of individual particles, and thus their origin(s) remains controversial. Using electron microscopy with subnanometer resolution, we show that ND separates from the Allende and Murchison meteorites are actually a two-phase mixture of ND and glassy carbon. This phase mixture is likely the product of supernova shock-wave transformation of pre-formed organics in the interstellar medium (ISM). The glassy carbon-ND mixture is also a plausible contributor to the 2175 A extinction feature in the diffuse ISM.

  17. Development of a pulse magnet of a superconducting storage ring and degradation of the pulse magnetic field by the vacuum chamber

    International Nuclear Information System (INIS)

    Tsukishima, Chihiro; Nakata, Shuhei

    1993-01-01

    A pulse magnet and its modulator are developed for a superconducting storage ring commissioning at Mitsubishi Electric Corp. The magnet is a window flame type one and uses a ceramic chamber with thin metallic coating for the vacuum shielding. The modulator generates a pulse current of 5.5 kA and the magnetic field is up to 1,300 G. The rise time of the field should be less than 300 ns in order to obtain enough injection efficiency to the storage ring. The shielding effects of the pulse magnetic field by the vacuum chamber are estimated using a three dimensional transient analysis program. The program solves the magnetic charge on the yoke surface of the magnet using the boundary element method and the eddy currents on the vacuum chamber using the network circuits method. The degradation of the magnetic field is measured by the search coil for different coating thickness to check the calculations results, and the results show good agreement with the calculation results. The calculation and the measurement results show the thickness should be less than 10 nm when the pulse width of the field is 600 ns. The dependence of the ununiformity of the coating thickness on the shielding effects is also estimated and the requirements for the uniformity are not so strict when the thickness is less than 10 nm. (author)

  18. Mathematical Development and Computational Analysis of Harmonic Phase-Magnetic Resonance Imaging (HARP-MRI) Based on Bloch Nuclear Magnetic Resonance (NMR) Diffusion Model for Myocardial Motion.

    Science.gov (United States)

    Dada, Michael O; Jayeoba, Babatunde; Awojoyogbe, Bamidele O; Uno, Uno E; Awe, Oluseyi E

    2017-09-13

    Harmonic Phase-Magnetic Resonance Imaging (HARP-MRI) is a tagged image analysis method that can measure myocardial motion and strain in near real-time and is considered a potential candidate to make magnetic resonance tagging clinically viable. However, analytical expressions of radially tagged transverse magnetization in polar coordinates (which is required to appropriately describe the shape of the heart) have not been explored because the physics required to directly connect myocardial deformation of tagged Nuclear Magnetic Resonance (NMR) transverse magnetization in polar geometry and the appropriate harmonic phase parameters are not yet available. The analytical solution of Bloch NMR diffusion equation in spherical geometry with appropriate spherical wave tagging function is important for proper analysis and monitoring of heart systolic and diastolic deformation with relevant boundary conditions. In this study, we applied Harmonic Phase MRI method to compute the difference between tagged and untagged NMR transverse magnetization based on the Bloch NMR diffusion equation and obtained radial wave tagging function for analysis of myocardial motion. The analytical solution of the Bloch NMR equations and the computational simulation of myocardial motion as developed in this study are intended to significantly improve healthcare for accurate diagnosis, prognosis and treatment of cardiovascular related deceases at the lowest cost because MRI scan is still one of the most expensive anywhere. The analysis is fundamental and significant because all Magnetic Resonance Imaging techniques are based on the Bloch NMR flow equations.

  19. Computational Modelling of Blood Flow Development and Its Characteristics in Magnetic Environment

    Directory of Open Access Journals (Sweden)

    Gopal Chandra Shit

    2013-01-01

    Full Text Available Of concern in this paper is an investigation of the entrance length behind singularities in cardiovascular hemodynamics under magnetic environment. In order to get better interpretation of scan MRI images, the characteristics of blood flow and electromagnetic field within the circulatory system have to be furthermore investigated. A 3D numerical model has been developed as an example of blood flowing through a straight circular tube. The governing coupled nonlinear differential equations of magnetohydrodynamic (MHD fluid flow are reduced to a nondimensional form, which are then characterized by four dimensionless parameters. With an aim to validate our numerical approach, the computational results are compared with those of the analytical solution available in the developed region far from the singularity. The hydraulic impedance by unit length within the developed flow region increases with the magnetic field. The time average entrance length with a greater precision on the unsteady case decreases with increasing magnetic field strength. The overall voltage characteristics do not depend on the developed flow field within the entry region.

  20. Design, Development and Scaling Analysis of a Variable Stiffness Magnetic Torsion Spring

    Directory of Open Access Journals (Sweden)

    Angelo Sudano

    2013-10-01

    Full Text Available In this paper we report on the design, modeling, experimental testing and scaling analysis of a novel MAgnetic Variable stiffnEess spRIng-Clutch (MAVERIC device, which may be used as the elastic element of Variable Stiffness Actuators (VSAs. The device, comprising two co-axial diametrically magnetized hollow cylinders, has two degrees of freedom: a rotation of the two cylinders around the common axis and a relative translation along the same axis. For small rotations, the torque arising from the magnetic interaction of the two cylinders is almost linearly proportional to their relative rotation, as in mechanical torsion springs. In addition, the stiffness of the equivalent spring can be varied continuously from a maximum value down to exactly zero by changing the axial overlap of the two cylinders. In this way the proposed device can be used both as a clutch (i.e., perfectly compliant element and as a variable stiffness torsion spring. A prototype, designed after magnetostatic FEM simulations, has been built and experimentally characterized. The developed MAVERIC has an experimentally determined maximum transmissible torque of 109.81mNm, while the calculated maximum stiffness is 110.2mNmrad−1. The amplitude of the torque-angle characteristic can be tuned linearly with a sensitivity of 12.63mNmmm−1 rad−1. Further simulations have been computed parameterizing the geometry and the number of pole pairs of the magnets. The maximum torque density reached for one pole pair is 47.21 · 103 Nm m−3, whereas for a fixed geometry similar to that of the developed prototype, the maximum torque is reached for seven pole pairs. Overall, compared to mechanical springs, MAVERIC has no fatigue or overloading issues. Compared to other magnetic couplers, torsion stiffness can be varied continuously from a maximum value down to exactly zero, when the device acts as a disengaged clutch, disconnecting the load from the actuator.

  1. Modeling of magnetic fields on a cylindrical surface and associated parameter estimation for development of a size sensor

    International Nuclear Information System (INIS)

    Zhang, Song; Rajamani, Rajesh

    2016-01-01

    This paper develops analytical sensing principles for estimation of circumferential size of a cylindrical surface using magnetic sensors. An electromagnet and magnetic sensors are used on a wearable band for measurement of leg size. In order to enable robust size estimation during rough real-world use of the wearable band, three estimation algorithms are developed based on models of the magnetic field variation over a cylindrical surface. The magnetic field models developed include those for a dipole and for a uniformly magnetized cylinder. The estimation algorithms used include a linear regression equation, an extended Kalman filter and an unscented Kalman filter. Experimental laboratory tests show that the size sensor in general performs accurately, yielding sub-millimeter estimation errors. The unscented Kalman filter yields the best performance that is robust to bias and misalignment errors. The size sensor developed herein can be used for monitoring swelling due to fluid accumulation in the lower leg and a number of other biomedical applications. (paper)

  2. Development of the Facility for Transformation of Magnetic Characteristics of Weakly Magnetic Oxidized Iron Ores Related to Improvement of Technologies for Iron Ore Concentrate Production

    Directory of Open Access Journals (Sweden)

    Ponomarenko, O.M.

    2016-01-01

    Full Text Available New facility for continuous registration of iron ore magnetization depending on temperature by heating of iron ores upon reducing conditions was created. Facility allows to register the processes of transformation of weakly magnetic minerals into strongly magnetic ones under the influence of reducing agents and temperature, as well as to determine the Curie temperature of the minerals. Using created facility it was shown, that heating of goethite and hematite in the presence of 4 % of starch in the temperature range of 300—650 °С leads to significant increase of magnetization of the samples. X-Ray diffraction confirmed that under indicated conditions the structure of hematite and goethite is transformed into magnetite structure. Obtained results open up new possibilities for the development of effective technologies for oxidized iron ore beneficiation.

  3. Recent development of high gradient superconducting magnetic separator for kaolin in China

    Energy Technology Data Exchange (ETDEWEB)

    Zhu, Zian; Wang, Meifen; Ning, Fei Peng; Yang, Huan; Zhang, Guoqing; Hou, Zhi Long; Liu, Zhaong Xiu; Dai, Zhong [Institute of High Energy Physics and University of Chinese Academy of Sciences, Beijing (China); Li, Pei Yong; Zhang, Yiting; Wang, Zhaolian [Weifang Xinli Superconducting Technology Co.,Ltd., Weifang (China)

    2017-03-15

    A series of high gradient superconducting magnetic separator (HGMS) for kaolin has been developed. It is used for processing kaolin to increase the brightness or whiteness whether it is for paper or ceramic applications. The HGMS system mainly consists of a solenoid magnet with a zero boil-off helium cryostat, a double reciprocating canisters system, and a PLC (Process Logic Controller) fully automatic control system based on SCADA (Supervisory Control and Data Acquisition) system. We have successfully developed CGC-5.5/300 and CGC-5.0/500 HGMS systems in the recent years, and now three sets of them are on-site operation in different customers. This paper will present recent progress of the HGMS system, the results of some experiments on processing kaolin clay used HGMS, and the on-site operation.

  4. Micromagnetic Code Development of Advanced Magnetic Structures Final Report CRADA No. TC-1561-98

    Energy Technology Data Exchange (ETDEWEB)

    Cerjan, Charles J. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Shi, Xizeng [Read-Rite Corporation, Fremont, CA (United States)

    2017-11-09

    The specific goals of this project were to: Further develop the previously written micromagnetic code DADIMAG (DOE code release number 980017); Validate the code. The resulting code was expected to be more realistic and useful for simulations of magnetic structures of specific interest to Read-Rite programs. We also planned to further the code for use in internal LLNL programs. This project complemented LLNL CRADA TC-840-94 between LLNL and Read-Rite, which allowed for simulations of the advanced magnetic head development completed under the CRADA. TC-1561-98 was effective concurrently with LLNL non-exclusive copyright license (TL-1552-98) to Read-Rite for DADIMAG Version 2 executable code.

  5. Development of the Floating Centrifugal Pump by Use of Non Contact Magnetic Drive and Its Performance

    Directory of Open Access Journals (Sweden)

    Mitsuo Uno

    2004-01-01

    Full Text Available This article focuses on the impeller construction, non contact driving method and performance of a newly developed shaftless floating pump with centrifugal impeller. The drive principle of the floating impeller pump used the magnet induction method similar to the levitation theory of the linear motor. In order to reduce the axial thrust by the pressure different between shroud and disk side, the balance hole and the aileron blade were installed in the floating impeller. Considering the above effect, floating of an impeller in a pump was realized. Moreover, the performance curves of a developed pump are in agreement with a general centrifugal pump, and the dimensionless characteristic curve also agrees under the different rotational speed due to no mechanical friction of the rotational part. Therefore, utility of a non contacting magnetic-drive style pump with the floating impeller was made clear.

  6. Magic-Angle-Spinning NMR Magnet Development: Field Analysis and Prototypes

    Science.gov (United States)

    Voccio, John; Hahn, Seungyong; Park, Dong Keun; Ling, Jiayin; Kim, Youngjae; Bascuñán, Juan; Iwasa, Yukikazu

    2013-01-01

    We are currently working on a program to complete a 1.5 T/75 mm RT bore magic-angle-spinning nuclear magnetic resonance magnet. The magic-angle-spinning magnet comprises a z-axis 0.866-T solenoid and an x-axis 1.225-T dipole, each to be wound with NbTi wire and operated at 4.2 K in persistent mode. A combination of the fields creates a 1.5-T field pointed at 54.74 degrees (magic angle) from the rotation (z) axis. In the first year of this 3-year program, we have completed magnetic analysis and design of both coils. Also, using a winding machine of our own design and fabrication, we have wound several prototype dipole coils with NbTi wire. As part of this development, we have repeatedly made successful persistent NbTi-NbTi joints with this multifilamentary NbTi wire. PMID:24058275

  7. Further technical development in magnetic resonance imaging of the brain in children

    International Nuclear Information System (INIS)

    Young, I.R.; Dubowitz, L.M.S.; Pennock, J.M.; Bydder, G.M.

    1988-01-01

    Further technical developments implemented in magnetic resonance imaging (MRI) of the brain in children are described. These include the use of longer data collection periods, T2-dependent field echoes, susceptibility mapping, short inversion time inversion recovery sequences, very long echo time spin-echo sequences, and phase mapping techniques to detect tissue perfusion. These techniques are illustrated in selected cases and have increased the range of options available in MR examinations of children. (author)

  8. The development of magnetic ion-source with high ionisation efficiency

    NARCIS (Netherlands)

    Veenstra, P.C.; Milatz, J.M.W.

    1950-01-01

    Starting from the principle given by A. Th. F i n k e l s t e i n l) , M. yon Ardenne2) 3) and W. Maas4), further development of the magnetic ion-source has been undertaken. The instrument has been designed especially for use with a 800 kV neutron generator described by W. M a a s 4) and under

  9. Traumatic Brain Injury Diffusion Magnetic Resonance Imaging Research Roadmap Development Project

    Science.gov (United States)

    2012-10-01

    optical imaging methods, PET/SPECT with radioisotope agents, and other technologies are less generally available or have known limitations. No “one...Brain Injury D-MRI Research Roadmap Development Project. Product Line Review (PLR) meeting, Medical Imaging Technologies. 12 June 2012. 11. Xia...meeting, Medical Imaging Technologies. Presentation slides. 12 June 2012. 1 Product Line Traumatic Brain Injury Diffusion Magnetic Resonance

  10. The development and modelling of devices and paradigms for transcranial magnetic stimulation.

    Science.gov (United States)

    Goetz, Stefan M; Deng, Zhi-De

    2017-04-01

    Magnetic stimulation is a non-invasive neurostimulation technique that can evoke action potentials and modulate neural circuits through induced electric fields. Biophysical models of magnetic stimulation have become a major driver for technological developments and the understanding of the mechanisms of magnetic neurostimulation and neuromodulation. Major technological developments involve stimulation coils with different spatial characteristics and pulse sources to control the pulse waveform. While early technological developments were the result of manual design and invention processes, there is a trend in both stimulation coil and pulse source design to mathematically optimize parameters with the help of computational models. To date, macroscopically highly realistic spatial models of the brain, as well as peripheral targets, and user-friendly software packages enable researchers and practitioners to simulate the treatment-specific and induced electric field distribution in the brains of individual subjects and patients. Neuron models further introduce the microscopic level of neural activation to understand the influence of activation dynamics in response to different pulse shapes. A number of models that were designed for online calibration to extract otherwise covert information and biomarkers from the neural system recently form a third branch of modelling.

  11. The development and modeling of devices and paradigms for transcranial magnetic stimulation

    Science.gov (United States)

    Goetz, Stefan M.; Deng, Zhi-De

    2017-01-01

    Magnetic stimulation is a noninvasive neurostimulation technique that can evoke action potentials and modulate neural circuits through induced electric fields. Biophysical models of magnetic stimulation have become a major driver for technological developments and the understanding of the mechanisms of magnetic neurostimulation and neuromodulation. Major technological developments involve stimulation coils with different spatial characteristics and pulse sources to control the pulse waveform. While early technological developments were the result of manual design and invention processes, there is a trend in both stimulation coil and pulse source design to mathematically optimize parameters with the help of computational models. To date, macroscopically highly realistic spatial models of the brain as well as peripheral targets, and user-friendly software packages enable researchers and practitioners to simulate the treatment-specific and induced electric field distribution in the brains of individual subjects and patients. Neuron models further introduce the microscopic level of neural activation to understand the influence of activation dynamics in response to different pulse shapes. A number of models that were designed for online calibration to extract otherwise covert information and biomarkers from the neural system recently form a third branch of modeling. PMID:28443696

  12. Development of radiation-resistant magnet coils for high-intensity beam lines

    Science.gov (United States)

    Tanaka, K. H.; Yamanoi, Y.; Noumi, H.; Takasaki, M.; Saitoh, Y.; Kato, K.; Yokoi, T.; Tsukada, S.; Tanno, H.

    1994-07-01

    In connection with the Japanese Hadron Facility (JHF) project, the development of new types of radiation-resistant magnet coils has been continued at KEK. One major program is the design and production of a mineral insulation cable (MIC) with a larger maximum current. We have already developed a 2000A-class MIC having a square-cross-section hollow conductor. A sample magnet coil was fabricated with this MIC. Tests of its stability and reliability are under progress. We are now planning to develop a 3000A-class MIC. The other program is R/D work on a completely inorganic wrapping insulation material which can be used like the usual type glass-fiber tape pre-impregnated with epoxy-resin. After tests of the mechanical strength and electric insulation of many combinations of tapes and bonds, we found a pure (99%) alumina-fiber tape pre-impregnated with inorganic cement that is suitable for a magnet coil insulator after thermal curing.

  13. Layer by layer assembly of glucose oxidase and thiourea onto glassy carbon electrode: Fabrication of glucose biosensor

    Energy Technology Data Exchange (ETDEWEB)

    Salimi, Abdollah, E-mail: absalimi@yahoo.com [Department of Chemistry, University of Kurdistsn, P.O. Box 416, Sanandaj (Iran, Islamic Republic of); Research Center for Nanotechnology, University of Kurdistan, P.O. Box 416, Sanandaj (Iran, Islamic Republic of); Noorbakhsh, Abdollah [Department of Chemistry, University of Kurdistsn, P.O. Box 416, Sanandaj (Iran, Islamic Republic of); Department of Nanotechnology Engenering, Faculty of Advanced Science and Technology, University of Isfahan, 81746-73441 (Iran, Islamic Republic of)

    2011-07-01

    Highlights: > Although various enzymes immobilization have been approve for the construction of glucose biosensor, a layer by layer (LBL) technique has attracted more attention due to simplicity of the procedure, wide choice of materials that can be used, controllability of film thickness and unique mechanical properties. > In this paper, we described a novel and simple strategy for developing an amperometric glucose biosensor based on layer-by-layer self assembly of glucose oxidase on the glassy carbon electrode modified by thiourea. > Thiourea has two amino groups that the one can be immobilized on the activated glassy carbon electrode and the other can be used for the coupling of glucose oxidase enzyme. > The biosensor exhibited good performance for electrocatalytic oxidation of glucose, such as high sensitivity, low detection limit, short response time and wide concentration range. > Finally, the new method is strongly recommended for immobilization of many other enzymes or proteins containing carbaldehyde or carboxylic groups for fabricating third generation biosensors and bioelectronics devices. - Abstract: For the first time a novel, simple and facile approach is described to construct highly stable glucose oxidase (GOx) multilayer onto glassy carbon (GC) electrode using thiourea (TU) as a covalent attachment cross-linker. The layer by layer (LBL) attachment process was confirmed by cyclic voltammetry, electrochemical impedance spectroscopy and Fourier transform infrared reflection spectroscopy (FT-IR-RS) techniques. Immobilized GOx shows excellent electrocatalytic activity toward glucose oxidation using ferrocenemethanol as artificial electron transfer mediator and biosensor response was directly correlated to the number of bilayers. The surface coverage of active GOx per bilayer, heterogeneous electron transfer rate constant (k{sub s}) and Michaelis-Menten constant (K{sub M}), of immobilized GOx were 1.50 x 10{sup -12} mol cm{sup -2}, 9.2 {+-} 0.5 s{sup -1

  14. The hydrophilic-to-hydrophobic transition in glassy silica is driven by the atomic topology of its surface

    Science.gov (United States)

    Yu, Yingtian; Krishnan, N. M. Anoop; Smedskjaer, Morten M.; Sant, Gaurav; Bauchy, Mathieu

    2018-02-01

    The surface reactivity and hydrophilicity of silicate materials are key properties for various industrial applications. However, the structural origin of their affinity for water remains unclear. Here, based on reactive molecular dynamics simulations of a series of artificial glassy silica surfaces annealed at various temperatures and subsequently exposed to water, we show that silica exhibits a hydrophilic-to-hydrophobic transition driven by its silanol surface density. By applying topological constraint theory, we show that the surface reactivity and hydrophilic/hydrophobic character of silica are controlled by the atomic topology of its surface. This suggests that novel silicate materials with tailored reactivity and hydrophilicity could be developed through the topological nanoengineering of their surface.

  15. Determination of 4-aminophenylarsonic acid using a glassy carbon electrode modified with an ionic liquid and carbon nanohorns

    International Nuclear Information System (INIS)

    Dai, Hong; Gong, Lingshan; Lu, Shuangyan; Zhang, Qingrong; Li, Yilin; Zhang, Shupei; Xu, Guifang; Li, Xiuhua; Lin, Yanyu; Chen, Guonan

    2015-01-01

    We have developed a sensor for 4-aminophenylarsonic acid (4-APhAA) by coating a glassy carbon electrode (GCE) with a composite prepared from an ionic liquid and dahlia-like carbon nanohorns (CNHs). The good electric conductivity, large surface area and high pore volume of the CNHs, and the synergistic action of the ionic liquid (which is a good dispersant with excellent ion conductivity) result in efficient electrocatalysis towards oxidation of 4-APhAA. The effect was investigated by various electrochemical methods, and the electron transfer coefficient, diffusion coefficient, standard heterogeneous rate constant and thermodynamic activation energy were determined. The response range of 4-APhAA was evaluated using an i-t plot. If operated at a working voltage of 900 mV (vs Ag/AgCl), the sensor responds to 4-APhAA over the 0.5 μM to 3.5 M concentration range. (author)

  16. A nanoscale characterisation of extended defects in glassy-like As 2Se 3 semiconductors with PAL technique

    Science.gov (United States)

    Shpotyuk, O.; Kovalskiy, A.; Filipecki, J.; Hyla, M.; Kozdras, A.

    2003-12-01

    A meaningful interpretation of positron lifetime characteristics for glassy-like g-As2Se3 is developed taking into account calculations of Jensen et al. (J. Non-Cryst. Solids 170 (1994) 57) for positrons trapped by free-volume extended defects in orthorhombic As2Se3 and void volume distribution for 146-atoms layer-biased model of amorphous As2Se3 presented by Popescu (J. Non-Cryst. Solids 35-36 (1980) 549). The obtained results are compared for samples having different thermal pre-history. Two groups of experimental results with close lifetime characteristics are distinguished for each of the investigated samples. This feature is explained in terms of average positron lifetime by applying two-state positron trapping model for mathematical treatment of the obtained spectra.

  17. Development of flexible array eddy current probes for complex geometries and inspection of magnetic parts using magnetic sensors

    Science.gov (United States)

    Marchand, B.; Decitre, J.-M.; Sergeeva-Chollet, N.; Skarlatos, A.

    2013-01-01

    Eddy Current Technique is a powerful method of inspection of metal parts. When size of flaws decreases, inspection areas become hardly accessible or material is magnetic, traditional winding coil probes are less efficient. Thanks to new CIVA simulation tools, we have designed and optimized advanced EC probes: flexible EC probe based on micro-coil arrays and EC probe with magnetic sensors, including specific electronics.

  18. Development of experiments for high-intensity laser plasma interaction in a magnetic field of the pulsed power generator

    Science.gov (United States)

    Ivanov, V. V.; Swanson, K. J.; Maximov, A. V.; Betti, R.; Sawada, H.; Mancini, R. C.; Sentoku, Y.; Wiewior, P. P.; Astanovitskiy, A. L.; Nalajala, V.; Chalyy, O.; Dmitriev, O.; Wong, N.

    2017-10-01

    Experiments were developed for investigation of the laser plasma interaction in the megagauss magnetic field of the 1MA Zebra pulsed power generator coupled with a 50TW laser. These experiments are relevant to astrophysical plasmas, particle and x-ray generation, and isochoric heating in a strong magnetic field. Magnetic fields in loads were measured with Faraday rotation in a glass sample placed near the load. 1-3MG longitudinal and transversal magnetic fields were measured in different loads. Impact of the fast rising magnetic field on metal laser targets was demonstrated. Focusing and targeting laser systems were integrated into the chamber of the Zebra generator. Shots at intensity of >1018 W/cm2 demonstrated collimation of plasma and generation of jets on the front and rear sides of the foil target in the axial magnetic field. Work was supported by the DOE Grant DE-SC0016500 and DOE/NNSA Grant DE-NA 0002075.

  19. Developing and validating a conceptual survey to assess introductory physics students’ understanding of magnetism

    Science.gov (United States)

    Li, Jing; Singh, Chandralekha

    2017-03-01

    Development of validated physics surveys on various topics is important for investigating the extent to which students master those concepts after traditional instruction and for assessing innovative curricula and pedagogies that can improve student understanding significantly. Here, we discuss the development and validation of a conceptual multiple-choice survey related to magnetism suitable for introductory physics courses. The survey was developed taking into account common students’ difficulties with magnetism concepts covered in introductory physics courses found in our investigation and the incorrect choices to the multiple-choice questions were designed based upon those common student difficulties. After the development and validation of the survey, it was administered to introductory physics students in various classes in paper-pencil format before and after traditional lecture-based instruction in relevant concepts. We compared the performance of students on the survey in the algebra-based and calculus-based introductory physics courses before and after traditional lecture-based instruction in relevant magnetism concepts. We discuss the common difficulties of introductory physics students with magnetism concepts we found via the survey. We also administered the survey to upper-level undergraduates majoring in physics and PhD students to benchmark the survey and compared their performance with those of traditionally taught introductory physics students for whom the survey is intended. A comparison with the base line data on the validated magnetism survey from traditionally taught introductory physics courses and upper-level undergraduate and PhD students discussed in this paper can help instructors assess the effectiveness of curricula and pedagogies which is especially designed to help students integrate conceptual and quantitative understanding and develop a good grasp of the concepts. In particular, if introductory physics students’ average

  20. Developing and validating a conceptual survey to assess introductory physics students’ understanding of magnetism

    International Nuclear Information System (INIS)

    Li, Jing; Singh, Chandralekha

    2017-01-01

    Development of validated physics surveys on various topics is important for investigating the extent to which students master those concepts after traditional instruction and for assessing innovative curricula and pedagogies that can improve student understanding significantly. Here, we discuss the development and validation of a conceptual multiple-choice survey related to magnetism suitable for introductory physics courses. The survey was developed taking into account common students’ difficulties with magnetism concepts covered in introductory physics courses found in our investigation and the incorrect choices to the multiple-choice questions were designed based upon those common student difficulties. After the development and validation of the survey, it was administered to introductory physics students in various classes in paper–pencil format before and after traditional lecture-based instruction in relevant concepts. We compared the performance of students on the survey in the algebra-based and calculus-based introductory physics courses before and after traditional lecture-based instruction in relevant magnetism concepts. We discuss the common difficulties of introductory physics students with magnetism concepts we found via the survey. We also administered the survey to upper-level undergraduates majoring in physics and PhD students to benchmark the survey and compared their performance with those of traditionally taught introductory physics students for whom the survey is intended. A comparison with the base line data on the validated magnetism survey from traditionally taught introductory physics courses and upper-level undergraduate and PhD students discussed in this paper can help instructors assess the effectiveness of curricula and pedagogies which is especially designed to help students integrate conceptual and quantitative understanding and develop a good grasp of the concepts. In particular, if introductory physics students’ average

  1. Modification of glassy carbon surfaces by atmospheric pressure cold plasma torch

    DEFF Research Database (Denmark)

    Mortensen, Henrik Junge; Kusano, Yukihiro; Leipold, Frank

    2006-01-01

    The effect of plasma treatment on glassy carbon (GC) surfaces was studied with adhesion improvement in mind. A newly constructed remote plasma source was used to treat GC plates. Pure He and a dilute NH3/He mixture were used as feed gases. Optical emission spectroscopy was performed for plasma...

  2. Preparation and characterization of dense graphite/glassy carbon composite coating for sealing application

    Science.gov (United States)

    Wang, Yang; Chen, Zhaofeng; Yu, Shengjie; Pan, Ning; Liao, Jiahao

    2017-09-01

    Glassy carbon (GC), characterized by a homogeneous structure and glass-like fracture surface once broken, has attracted increasing attention because of its excellent performance. In this paper, a dense graphite/glassy carbon composite coating with low gas permeability was introduced. In this composite coating, small graphite particles acting as second phase were wrapped by glassy carbon matrix. The composite coatings with different mass fractions of graphite particles were prepared. The mass loss of phenolic resin was determined by TG (thermogravimetry) analysis to determine the pyrolysis process. Raman spectrum analysis indicates that graphite content in composite coatings affected the G/D ratio significantly. The permeability of composite coatings with 50% and 100% graphite particles was almost same, which was ranged from 6  ×  10-13 m3 · µm/m2 · s · Pa to 3  ×  10-13 m3 · µm/m2 · s · Pa within the differential pressure from 100 kPa to 70 kPa. While the composite coating with 150% graphite particles had higher gas permeability due to the tiny micro-cracks and micro-pores produced. What was more, the densification mechanism of graphite/glassy carbon composite coating was also discussed in detail.

  3. Dielectric relaxation in glassy Se75In25−xPbx alloys

    Indian Academy of Sciences (India)

    to their atomic percentages and were sealed in quartz ampoules (length ~5 cm and internal dia. ~8 mm) in vacuum ... samples were taken out by breaking the quartz ampoules. The glassy nature of the ... measured with the help of a calibrated copper–constantan thermocouple mounted very near to the sample, which could ...

  4. Glassy-winged sharpshooter oviposition effects on foliar grapevine and red-tipped photinia terpenoid levels

    Science.gov (United States)

    The glassy-winged sharpshooter (GWSS), Homalodisca vitripennis (Germar) (Hemiptera: Cicadellidae), is an important vector of Xylella fastidiosa, the bacterium that causes Pierce's disease of grapevine and is a threat to grape production throughout the United States. Female GWSS deposit egg masses be...

  5. An extensive study of electrochemical behavior of brimonidine and its determination at glassy carbon electrode

    International Nuclear Information System (INIS)

    Aleksić, Mara M.; Radulović, Valentina; Agbaba, Danica; Kapetanović, Vera

    2013-01-01

    Highlights: • The electrochemical behavior of BRIM was investigated by CV, DPV and SWV at GCE. • The effects of pH, scan rate and BRIM concentriation was studied. • The nature of the electrode process, and the mechanism scheme was proposed. • DPV method was developed for the estimation of BRIM in the Alphagan eye drops. -- Abstract: The electrochemical behavior of brimonidine (BRIM), an antiglaucoma agent applied in therapy for lowering high intraocular pressure, was investigated by cyclic voltammetry, differential pulse voltammetry and square wave voltammetry using a glassy carbon electrode (GCE). The reduction of BRIM occurs as one-step quasi-reversible reaction in acid and neutral medium, reaching the full reversibility in alkaline solutions. Reduction process involves the transfer of two electrons and two protons at the pyrazine ring of quinoxaline moiety, forming a dihydro-derivative. In acid and neutral solutions, brimonidine reduction product is partly oxidized to its hydroxy-derivative. BRIM is also oxidized irreversibly with the transfer of one electron and one proton at secondary amine moiety. The effects of pH of the electrolyte solution, scan rate and BRIM concentration were monitored. The nature of the electrode process was found to be controlled by the adsorption at pH > 6 and the total surface concentration of brimonidine adsorbed onto the GCE surface at pH 7, Γ BRIM = 1.35 × 10 −10 mol cm −2 was obtained. Based on this study, differential pulse voltammetric method was developed, validated and suggested for rapid electroanalytical determination of the low concentration of brimonidine. The linearity was achieved within the concentration range from 5 × 10 −7 to 5 × 10 −6 M with LOD = 1.6 × 10 −7 M and LOQ = 5.3 × 10 −7 M. The method was applied for brimonidine determination in pharmaceutical dosage form, eye drops

  6. On the Development of a Magnetically Vectored Variable ISP Plasma Rocket

    Science.gov (United States)

    Feliciano, Enectali Figueroa; Diaz, Franklin R. Chang; Squire, Jared P.

    1997-01-01

    The development of a Magnetically Vectored Variable I(sub sp) Plasma Rocket at the Advanced Space Propulsion Laboratory (ASPL) is in progress at NASA's Johnson Space Center. The facility is using a small, 3.2 m tandem mirror device to study the application of RF heated magnetically contained plasmas for space propulsion. The central cell radius is 0.1 m and fields of 0.2 T and 2 T are possible in the central and end-cell mirror sections, respectively. A magnetoplasmadynamic (MPD) injector has just been acquired and will be used along with other methods of plasma refueling. A 1 MW magnet power supply upgrade is being developed with full implementation by the Spring of 1997. Two microwave systems for discharge initiation and plasma heating at 2.45 GHz and 14.0 GHz, respectively, are in operation. Additionally, RF systems with 200 kW and 1 MW of power are being modified and conditioned for operation. The concept provides electrode-less operation and variable thrush'specific impulse at constant power (200 -30 N /5000-30,000 seconds at 10 MW with a 60% efficiency). Optimization for speed or payload are possible with the same engine, giving the rocket great flexibility. Missions to Mars in 90 days are described, and missions to Pluto are under study.

  7. Development of magnetic nanoparticle based calorimetric assay for the detection of bovine mastitis in cow milk.

    Science.gov (United States)

    Chinnappan, Raja; Al Attas, Sana; Kaman, Wendy E; Bikker, Floris J; Zourob, Mohammed

    2017-04-15

    Mastitis in dairy cattle is an inflammatory reaction of the udder tissue. Mastitis increases plasmin levels, leading to an increased proteolysis of milk proteins such as casein, resulting in a significant decrease in milk quality and related dairy products. Due to its key-role in mastitis, we used plasmin proteolytic activity as a biomarker for the detection of mastitis in bovine mastitic milk. Inspired by earlier studies on protease activity using mastitic milk samples, we developed a simple colorimetric assay to distinguish mastitic milk from milk derived from healthy animals. The plasmin substrate coupled to magnetic nanoparticles form a black self-assembled monolayer on a gold sensor surface. In the presence of increased levels of plasmin, the substrate is cleaved and the peptide fragment attached to the magnetic beads, will be attracted by the magnet which is present under the sensor strips revealing the golden surface. We found the area of the golden color surface proportional to plasmin activity. The sensitivity of this method was determined to be 1 ng/ml of plasmin in vitro. Next, we tested the biosensor using mastitis positive milk of which infection is confirmed by bacterial cultures. This newly developed colorimetric biosensor has high potential in applications for the diagnosis of mastitis with potential spin offs to health, food and environmental sectors. Copyright © 2017 Elsevier Inc. All rights reserved.

  8. Development and functionalization of magnetic nanoparticles as powerful and green catalysts for organic synthesis

    Directory of Open Access Journals (Sweden)

    Ahmed M. Abu-Dief

    2018-03-01

    Full Text Available Magnetic nanoparticles are a highly worthy reactant for the correlation of homogeneous inorganic and organic containing catalysts. This review deals with the very recent main advances in the development of various nano catalytic systems by the immobilization of homogeneous catalysts onto magnetic nanoparticles. Catalytic fields include the use of mainly cobalt, nickel, copper, and zinc ferrites, as well as their mixed-metal combinations with Cr, Cd, Mn and sometimes some lanthanides. The ferrite nanomaterials are obtained mainly by co-precipitation and hydrothermal methods, sometimes by the sonochemical technique, micro emulsion and flame spray synthesis route. Catalytic processes with application of ferrite nanoparticles include degradation (in particular photocatalytic, reactions of dehydrogenation, oxidation, alkylation, C–C coupling, among other processes. Ferrite nano catalysts can be easily recovered from reaction systems and reused up to several runs almost without loss of catalytic activity. Finally, we draw conclusions and present a futurity outlook for the further development of new catalytic systems which are immobilized onto magnetic nanoparticles.

  9. Development of a magnetic nanoparticles microarray for simultaneous and simple detection of foodborne pathogens.

    Science.gov (United States)

    Li, Song; Liu, Hongna; Deng, Yan; Lin, Lin; He, Nongyue

    2013-07-01

    Foodborne diseases are a widespread and growing public health problem affecting both developed and developing countries, microbiologically contaminated food and water are the major causes of diarrhoeal diseases. Methods based on polymerase chain reaction (PCR) and microarrays are rapid and sensitive enough to detect very small quantities of microorganisms, however, the requirement for expensive equipments limits their application. In the present paper, we describe a method based on multiplex PCR and magnetic nanoparticles labelling for simultaneous detection of four major foodborne pathogens, including Escherichia coli O157:H7, Salmonella enterica, Vibrio cholera and Campylobacter jejuni. The process utilizes an oligonucleotide array onto which 5' biotinylated single strand PCR products were hybridized and visualized with streptavidin-coated magnetic nanoparticles (SA-MNPs), the signal from which could be detected by the naked eye, microscope or CCD camera. By employing SA-MNPs as visible labels, the microarray unambiguously distinguished all 4 pathogens with detection sensitivity up to 316 CFU/mL. Due to its high sensitivity, specificity and simple detection procedure, the magnetic bead assay provides a powerful tool for the detection and identification of foodborne pathogens in a modestly equipped laboratory.

  10. Development of a Hybrid Piezo Natural Rubber Piezoelectricity and Piezoresistivity Sensor with Magnetic Clusters Made by Electric and Magnetic Field Assistance and Filling with Magnetic Compound Fluid

    Directory of Open Access Journals (Sweden)

    Kunio Shimada

    2017-02-01

    Full Text Available Piezoelements used in robotics require large elasticity and extensibility to be installed in an artificial robot skin. However, the piezoelements used until recently are vulnerable to large forces because of the thin solid materials employed. To resolve this issue, we utilized a natural rubber and applied our proposed new method of aiding with magnetic and electric fields as well as filling with magnetic compound fluid (MCF and doping. We have verified the piezoproperties of the resulting MCF rubber. The effect of the created magnetic clusters is featured in a new two types of multilayered structures of the piezoelement. By measuring the piezoelectricity response to pressure, the synergetic effects of the magnetic clusters, the doping and the electric polymerization on the piezoelectric effect were clarified. In addition, by examining the relation between the piezoelectricity and the piezoresistivity created in the MCF piezo element, we propose a hybrid piezoelement.

  11. Development of a Hybrid Piezo Natural Rubber Piezoelectricity and Piezoresistivity Sensor with Magnetic Clusters Made by Electric and Magnetic Field Assistance and Filling with Magnetic Compound Fluid.

    Science.gov (United States)

    Shimada, Kunio; Saga, Norihiko

    2017-02-10

    Piezoelements used in robotics require large elasticity and extensibility to be installed in an artificial robot skin. However, the piezoelements used until recently are vulnerable to large forces because of the thin solid materials employed. To resolve this issue, we utilized a natural rubber and applied our proposed new method of aiding with magnetic and electric fields as well as filling with magnetic compound fluid (MCF) and doping. We have verified the piezoproperties of the resulting MCF rubber. The effect of the created magnetic clusters is featured in a new two types of multilayered structures of the piezoelement. By measuring the piezoelectricity response to pressure, the synergetic effects of the magnetic clusters, the doping and the electric polymerization on the piezoelectric effect were clarified. In addition, by examining the relation between the piezoelectricity and the piezoresistivity created in the MCF piezo element, we propose a hybrid piezoelement.

  12. Alterations of the Temporomandibular Joint on Magnetic Resonance Imaging according to Growth and Development in Schoolchildren

    Directory of Open Access Journals (Sweden)

    Tatsurou Tanaka

    2012-01-01

    Full Text Available The paper explains the alterations of the temporomandibular joint (TMJ visualized by magnetic resonance imaging (MRI according to the growth and development of schoolchildren. Appearance and disappearance of a “double contour-like structure” (DCLS of the mandibular condyle on MRI according to the growth and development of schoolchildren were demonstrated. In addition, possible constituents of DCLS and the significance of detection of DCLS on MRI were also speculated. The relationship between red marrow and yellow marrow in the articular eminence of temporal bone, the disappearance of DCLS, and alterations of the mandibular condyle have been elucidated.

  13. Development and applications of a new computer-controlled magnetic inspection system

    Science.gov (United States)

    Eichmann, A. R.

    1992-07-01

    The magnetic hysteresis inspection technique has been shown to obtain results that can be traceable to the fundamental properties of the material. A new computer-controlled instrument known as the Magnescope Mark 2 was developed which can be used to make magnetic hysteresis inspections on materials in situ. These inspections can be used to evaluate the condition of steel components non-destructively allowing it to be used in applications such as quality control and assurance in the production of steel and for evaluating the structural integrity of steel components. Previous inspections systems based on this technique were large, heavy, and hard to use making measurements out in the field difficult to obtain. The Magnescope Mark 2 was designed to be smaller, lighter, and easier to use allowing field measurements to be obtained much easier. The design and construction of the Magnescope Mark 2 is described along with the improvements and additions made to the control and analysis software known as MAGNUM.

  14. Development of Bi-2212/Ag round-shaped wire and magnet application

    International Nuclear Information System (INIS)

    Okada, M.

    2000-01-01

    Recent achievements in the newly-developed Bi-2212/Ag round-shaped wire with tape-shaped multifilaments are summarized. The new round-shaped wire includes 126-1320 tape-shaped filaments with triple rotation symmetry, having a good crystal alignment of Bi-2212 in each filament. We refer to the new wire as ROSATwire, (ROtation-Symmetric Arranged Tape-in-tube wire). The ROSATwire fabrication process markedly improved productivity and lowered the cost, and also improved the transport J c of the wire. The I c and J c reached values greater than 340 A and 1000 A mm -2 , respectively, at 28 T and 4 K. Insulated wires of over 400 m length, 2 mm in diameter, are now available and ready for magnet winding. Several solenoid magnets with a 130-160 mm outer diameter and 100-600 mm height are now under fabrication. (author)

  15. Development of metal-resin composite for dental magnet keepers, Part 2: Optimum 4-META content.

    Science.gov (United States)

    Soma, Hiroko; Miyagawa, Yukio

    2011-01-01

    Six kinds of experimental magnetic resin composites containing SUS447J1 stainless steel particles as filler were prepared. UDMA/MAA resin with an MAA mole fraction of 0.67 was used as the matrix resin. The effects of six levels of 4-META content (2, 4, 6, 8, 10, and 12 mass%) on the setting and flexural properties were studied. The metal filler content in each paste was 90 mass%. Although working time and setting time significantly diminished with the increase of the BPO and DMPT contents, both working time and setting time satisfied the ISO 4049 requirements for all experimental levels. Flexural strength and elastic modules significantly improved with the increase of 4-META content up to 10%. The optimum 4-META content necessary to develop better composite resins for magnetic attachment has been clarified.

  16. Annealing effects on the migration of ion-implanted cadmium in glassy carbon

    Energy Technology Data Exchange (ETDEWEB)

    Hlatshwayo, T.T., E-mail: thulani.hlatshwayo@up.ac.za [Physics Department, University of Pretoria, Pretoria (South Africa); Sebitla, L.D. [Physics Department, University of Pretoria, Pretoria (South Africa); Physics Department, University of Botswana, Gaborone (Botswana); Njoroge, E.G.; Mlambo, M.; Malherbe, J.B. [Physics Department, University of Pretoria, Pretoria (South Africa)

    2017-03-15

    The migration behaviour of cadmium (Cd) implanted into glassy carbon and the effects of annealing on radiation damage introduced by ion implantation were investigated. The glassy carbon substrates were implanted with Cd at a dose of 2 × 10{sup 16} ions/cm{sup 2} and energy of 360 keV. The implantation was performed at room temperature (RT), 430 °C and 600 °C. The RT implanted samples were isochronally annealed in vacuum at 350, 500 and 600 °C for 1 h and isothermally annealed at 350 °C up to 4 h. The as-implanted and annealed samples were characterized by Raman spectroscopy and Rutherford backscattering spectrometry (RBS). Raman results revealed that implantation at room temperature amorphized the glassy carbon structure while high temperature implantations resulted in slightly less radiation damage. Isochronal annealing of the RT implanted samples resulted in some recrystallization as a function of increasing temperature. The original glassy carbon structure was not achieved at the highest annealing temperature of 600 °C. Diffusion of Cd in glassy carbon was already taking place during implantation at 430 °C. This diffusion of Cd was accompanied by significant loss from the surface during implantation at 600 °C. Isochronal annealing of the room temperature implanted samples at 350 °C for 1 h caused Cd to diffuse towards the bulk while isothermal annealing at 500 and 600 °C resulted in the migration of implanted Cd toward the surface accompanied by a loss of Cd from the surface. Isothermal annealing at 350 °C for 1 h caused Cd to diffuse towards the bulk while for annealing time >1 h Cd diffused towards the surface. These results were interpreted in terms of trapping and de-trapping of implanted Cd by radiation damage.

  17. Co-based soft magnetic bulk glassy alloys optimized for glass ...

    Indian Academy of Sciences (India)

    [4] Xu D H, Duan G and Johnson W L 2004 Phys. Rev. Lett. 92. 245504. [5] Ponnambalam V, Poon S J and Shiflet G J 2004 J. Mater. Res. 19 1320. [6] Zhang B, Zhao D Q, Pan M X, Wang W H and Greer A L. 2005 Phys. Rev. Lett. 94 205502. [7] Lu Z P, Liu C T, Thompson J R and Porter W D 2004 Phys. Rev. Lett. 92 245503.

  18. Injection-Molded Soft Magnets Prepared from Fe-Based Metallic Glass: Mechanical and Magnetic Properties

    Science.gov (United States)

    Zhong, Tian; Huang, Ran; Huang, Jia; Ouyang, Wei

    2015-10-01

    The injection-molded metallic glass soft magnet is prepared from the powder of melt-spun ribbon of Fe36Co36B20Si4Nb4 glassy alloy and Nylon 6,6 of wt.% from 5 to 20 via the polymer injection molding technology. The product is characterized by the SEM, mechanical, and magnetic test. The results indicate that this type of materials has comparable mechanical properties and morphological feature with the conventional injection-molded NdFeB magnet and exhibits excellent soft magnetic behaviors. The magnetic properties of the injected magnets are compared with the raw metallic glass, solvent-casted resin bonding magnets, and thermal-treated magnets to confirm that the processing temperature of Nylon injection does not affect the magnetism. The injection technology is a practical processing method to be applied on the metallic glass for potential usage.

  19. Superconducting magnets

    International Nuclear Information System (INIS)

    1994-08-01

    This report discusses the following topics on superconducting magnets: D19B and -C: The next steps for a record-setting magnet; D20: The push beyond 10 T: Beyond D20: Speculations on the 16-T regime; other advanced magnets for accelerators; spinoff applications; APC materials development; cable and cabling-machine development; and high-T c superconductor at low temperature

  20. Glassy carbon electrodes modified with multiwalled carbon nanotubes for the determination of ascorbic acid by square-wave voltammetry

    Directory of Open Access Journals (Sweden)

    Sushil Kumar

    2012-05-01

    Full Text Available Multiwalled carbon nanotubes were used to modify the surface of a glassy carbon electrode to enhance its electroactivity. Nafion served to immobilise the carbon nanotubes on the electrode surface. The modified electrode was used to develop an analytical method for the analysis of ascorbic acid (AA by square-wave voltammetry (SWV. The oxidation of ascorbic acid at the modified glassy carbon electrode showed a peak potential at 315 mV, about 80 mV lower than that observed at the bare (unmodified electrode. The peak current was about threefold higher than the response at the bare electrode. Replicate measurements of peak currents showed good precision (3% rsd. Peak currents increased with increasing ascorbic acid concentration (dynamic range = 0.0047–5.0 mmol/L and displayed good linearity (R2 = 0.994. The limit of detection was 1.4 μmol/L AA, while the limit of quantitation was 4.7 μmol/L AA. The modified electrode was applied to the determination of the amount of ascorbic acid in four brands of commercial orange-juice products. The measured content agreed well (96–104% with the product label claim for all brands tested. Recovery tests on spiked samples of orange juice showed good recovery (99–104%. The reliability of the SWV method was validated by conducting parallel experiments based on high-performance liquid chromatography (HPLC with absorbance detection. The observed mean AA contents of the commercial orange juice samples obtained by the two methods were compared statistically and were found to have no significant difference (P = 0.05.

  1. Electrocatalytic oxidation of deferiprone and its determination on a carbon nanotube-modified glassy carbon electrode

    Energy Technology Data Exchange (ETDEWEB)

    Yadegari, H. [Department of Chemistry, Faculty of Science, K.N. Toosi University of Technology, P.O. Box 16315-1618, Tehran (Iran, Islamic Republic of); Jabbari, A. [Department of Chemistry, Faculty of Science, K.N. Toosi University of Technology, P.O. Box 16315-1618, Tehran (Iran, Islamic Republic of)], E-mail: jabbari@kntu.ac.ir; Heli, H.; Moosavi-Movahedi, A.A. [Institute of Biochemistry and Biophysics, University of Tehran, Tehran (Iran, Islamic Republic of); Karimian, K. [Arasto Pharmaceutical Chemicals Inc., Tehran (Iran, Islamic Republic of); Khodadadi, A. [Department of Chemical Engineering, Faculty of Engineering, University of Tehran, Tehran (Iran, Islamic Republic of)

    2008-02-15

    The electrochemical behavior of the anti-thalassemia and anti-HIV replication drug, deferiprone, was investigated on a carbon nanotube-modified glassy carbon (GC-CNT) electrode in phosphate buffer solution, pH 7.40 (PBS). During oxidation of deferiprone, two irreversible anodic peaks, with E{sub 1}{sup 0}=452 and E{sub 2}{sup 0}=906mV, appeared, using GC-CNT. Cyclic voltammetric study indicated that the oxidation process is irreversible and diffusion controlled. The number of exchanged electrons in the electro-oxidation process was obtained, and the data indicated that deferiprone is oxidized via two two-electron steps. The results revealed that carbon nanotube (CNT) promotes the rate of oxidation by increasing the peak current, so that deferiprone is oxidized at lower potentials, which thermodynamically is more favorable. This result was confirmed by impedance measurements. The diffusion coefficient, electron-transfer coefficient and heterogeneous electron-transfer rate constant of deferiprone were found to be 1.49 x 10{sup -6} cm{sup 2} s{sup -1}, 0.44, and 3.83 x 10{sup -3} cm s{sup -1}, respectively. A sensitive, simple and time-saving differential-pulse voltammetric procedure was developed for the analysis of deferiprone. Using the proposed method, deferiprone can be determined with a detection limit of 5.25 x 10{sup -7} M. The applicability of the method to direct assays of spiked human serum and urine fluids is described.

  2. Sequencing and de novo assembly of the transcriptome of the glassy-winged sharpshooter (Homalodisca vitripennis.

    Directory of Open Access Journals (Sweden)

    Raja Sekhar Nandety

    Full Text Available BACKGROUND: The glassy-winged sharpshooter Homalodisca vitripennis (Hemiptera: Cicadellidae, is a xylem-feeding leafhopper and important vector of the bacterium Xylella fastidiosa; the causal agent of Pierce's disease of grapevines. The functional complexity of the transcriptome of H. vitripennis has not been elucidated thus far. It is a necessary blueprint for an understanding of the development of H. vitripennis and for designing efficient biorational control strategies including those based on RNA interference. RESULTS: Here we elucidate and explore the transcriptome of adult H. vitripennis using high-throughput paired end deep sequencing and de novo assembly. A total of 32,803,656 paired-end reads were obtained with an average transcript length of 624 nucleotides. We assembled 32.9 Mb of the transcriptome of H. vitripennis that spanned across 47,265 loci and 52,708 transcripts. Comparison of our non-redundant database showed that 45% of the deduced proteins of H. vitripennis exhibit identity (e-value ≤1(-5 with known proteins. We assigned Gene Ontology (GO terms, Kyoto Encyclopedia of Genes and Genomes (KEGG annotations, and potential Pfam domains to each transcript isoform. In order to gain insight into the molecular basis of key regulatory genes of H. vitripennis, we characterized predicted proteins involved in the metabolism of juvenile hormone, and biogenesis of small RNAs (Dicer and Piwi sequences from the transcriptomic sequences. Analysis of transposable element sequences of H. vitripennis indicated that the genome is less expanded in comparison to many other insects with approximately 1% of the transcriptome carrying transposable elements. CONCLUSIONS: Our data significantly enhance the molecular resources available for future study and control of this economically important hemipteran. This transcriptional information not only provides a more nuanced understanding of the underlying biological and physiological mechanisms that

  3. Micro-magnetic resonance imaging study of live quail embryos during embryonic development.

    Science.gov (United States)

    Duce, Suzanne; Morrison, Fiona; Welten, Monique; Baggott, Glenn; Tickle, Cheryll

    2011-01-01

    Eggs containing live Japanese quail embryos were imaged using micro-magnetic resonance imaging (μMRI) at 24-h intervals from Day 0 to 8, the period during which the main body axis is being laid down and organogenesis is taking place. Considerable detail of non-embryonic structures such as the latebra was revealed at early stages but the embryo could only be visualized around Day 3. Three-dimensional (3D) changes in embryo length and volume were quantified and also changes in volume in the extra- and non-embryonic components. The embryo increased in length by 43% and nearly trebled in volume between Day 4 and Day 5. Although the amount of yolk remained fairly constant over the first 5 days, the amount of albumen decreases significantly and was replaced by extra-embryonic fluid (EEF). ¹H longitudinal (T₁) and transverse (T₂) relaxation times of different regions within the eggs were determined over the first 6 days of development. The T₂ measurements mirrored the changes in image intensity observed, which can be related to the aqueous protein concentrations. In addition, a comparison of the development of Day 0 to 3 quail embryos exposed to radiofrequency (rf) pulses, 7 T static magnetic fields and magnetic field gradients for an average of 7 h with the development of control embryos did not reveal any gross changes, thus confirming that μMRI is a suitable tool for following the development of live avian embryos over time from the earliest stages. Copyright © 2011 Elsevier Inc. All rights reserved.

  4. Development and testing of a magnetic position sensor system for automotive and avionics applications

    Science.gov (United States)

    Jacobs, Bryan C.; Nelson, Carl V.

    2001-08-01

    A magnetic sensor system has been developed to measure the 3-D location and orientation of a rigid body relative to an array of magnetic dipole transmitters. A generalized solution to the measurement problem has been formulated, allowing the transmitter and receiver parameters (position, orientation, number, etc.) to be optimized for various applications. Additionally, the method of images has been used to mitigate the impact of metallic materials in close proximity to the sensor. The resulting system allows precise tracking of high-speed motion in confined metal environments. The sensor system was recently configured and tested as an abdomen displacement sensor for an automobile crash-test dummy. The test results indicate a positional accuracy of approximately 1 mm rms during 20 m/s motions. The dynamic test results also confirmed earlier covariance model predictions, which were used to optimize the sensor geometry. A covariance analysis was performed to evaluate the applicability of this magnetic position system for tracking a pilot's head motion inside an aircraft cockpit. Realistic design parameters indicate that a robust tracking system, consisting of lightweight pickup coils mounted on a pilot's helmet, and an array of transmitter coils distributed throughout a cockpit, is feasible. Recent test and covariance results are presented.

  5. Axial magnetic bearing development for the BiVACOR rotary BiVAD/TAH.

    Science.gov (United States)

    Greatrex, Nicholas A; Timms, Daniel L; Kurita, Nobuyuki; Palmer, Edward W; Masuzawa, Toru

    2010-03-01

    A suspension system for the BiVACOR biventricular assist device (BiVAD) has been developed and tested. The device features two semi-open centrifugal impellers mounted on a common rotating hub. Flow balancing is achieved through the movement of the rotor in the axial direction. The rotor is suspended in the pump casings by an active magnetic suspension system in the axial direction and a passive hydrodynamic bearing in the radial direction. This paper investigates the axial movement capacity of the magnetic bearing system and the power consumption at various operating points. The force capacity of the passive hydrodynamic bearing is investigated using a viscous glycerol solution. Axial rotor movement in the range of +/-0.15 mm is confirmed and power consumption is under 15.5 W. The journal bearing is shown to stabilize the rotor in the radial direction at the required operating speed. Magnetic levitation is a viable suspension technique for the impeller of an artificial heart to improve device lifetime and reduce blood damage.

  6. Development of organic magnets aided by captodative effect; Captodative koka wo riyoshita yuki jiseitai no kaihatsu

    Energy Technology Data Exchange (ETDEWEB)

    Tanaka, H. [Tokushima University, Tokushima (Japan). Faculty of Engineering

    1994-12-15

    With an objective of developing organic magnets, a cryogenic synthesis was attempted by utilizing captodative effect of polymers with ladder structure (resonant stabilization of unpaired electrons generated when electron donor groups and receiving groups are substituted with the same atoms simultaneously). The study performed oxidizing polymerization under lights irradiated from captodative substituted methanes at room temperature or 130{degree}C. It was verified from IR that the polymer cycling has proceeded and the ladder structure was formed. Resonant peaks originated from the unpaired electrons were recognized in these products, and so were those that respond to a permanent magnet, and their magnetic susceptibility follows the Curie/Weiss expression. Indigo derivatives were synthesized to measure the ESP spectra. In indigo polymers, monoradical species perform positive exchange interactions forming a high spin domain. It was inferred from the ESR comparison of nuclear substituted indigo derivatives that the unpaired electrons are located on captodative substituted C atoms and the hydrogen bonding facilitates intermolecular spin actions and spinning interactions. 5 refs., 4 figs., 2 tabs.

  7. Instrument developments for magnetic and high-resolution diffraction at the XMaS beamline

    International Nuclear Information System (INIS)

    Brown, S.D.; Thompson, P.; Cooper, M.J.; Kervin, J.; Paul, D.F.; Stirling, W.G.; Stunault, A.

    2001-01-01

    The XMaS beamline is situated on dipole BM28 at the European Synchrotron Radiation Facility (ESRF). It has been designed to perform magnetic and high-resolution diffraction for a British Collaborating Research Group (CRG) over an energy range of 3-15 keV in a focused monochromatic beam mode. Since the beamline became operational in April 1998, various instrument developments have been made. These include both mechanical and opto-mechanical devices of general interest to the SR community, three of which are highlighted in this paper. Firstly, a motorised x,y,z sample mount capable of holding an APD cryostat has been developed; this device is useful not only for initial sample alignment, but also in mapping a sample for the location of single crystallites. Secondly, novel in-vacuum slits have been developed which allow definition of the beam footprint close to the sample. Thirdly, together with Huber Diffraction GmbH, an in-vacuum polarisation analyser for the analysis of magnetic scattering has been developed

  8. Development of techniques in magnetic resonance and structural studies of the prion protein

    Energy Technology Data Exchange (ETDEWEB)

    Bitter, Hans-Marcus L. [Univ. of California, Berkeley, CA (United States)

    2000-07-01

    Magnetic resonance is the most powerful analytical tool used by chemists today. Its applications range from determining structures of large biomolecules to imaging of human brains. Nevertheless, magnetic resonance remains a relatively young field, in which many techniques are currently being developed that have broad applications. In this dissertation, two new techniques are presented, one that enables the determination of torsion angles in solid-state peptides and proteins, and another that involves imaging of heterogenous materials at ultra-low magnetic fields. In addition, structural studies of the prion protein via solid-state NMR are described. More specifically, work is presented in which the dependence of chemical shifts on local molecular structure is used to predict chemical shift tensors in solid-state peptides with theoretical ab initio surfaces. These predictions are then used to determine the backbone dihedral angles in peptides. This method utilizes the theoretical chemicalshift tensors and experimentally determined chemical-shift anisotropies (CSAs) to predict the backbone and side chain torsion angles in alanine, leucine, and valine residues. Additionally, structural studies of prion protein fragments are described in which conformationally-dependent chemical-shift measurements were made to gain insight into the structural differences between the various conformational states of the prion protein. These studies are of biological and pathological interest since conformational changes in the prion protein are believed to cause prion diseases. Finally, an ultra-low field magnetic resonance imaging technique is described that enables imaging and characterization of heterogeneous and porous media. The notion of imaging gases at ultra-low fields would appear to be very difficult due to the prohibitively low polarization and spin densities as well as the low sensitivities of conventional Faraday coil detectors. However, Chapter 5 describes how gas imaging

  9. Development of a cryogenically cooled platform for the Magnetized Liner Inertial Fusion (MagLIF) Program

    Science.gov (United States)

    Awe, T. J.; Shelton, K. P.; Sefkow, A. B.; Lamppa, D. C.; Baker, J. L.; Rovang, D. C.; Robertson, G. K.

    2017-09-01

    A cryogenically cooled hardware platform has been developed and commissioned on the Z Facility at Sandia National Laboratories in support of the Magnetized Liner Inertial Fusion (MagLIF) Program. MagLIF is a magneto-inertial fusion concept that employs a magnetically imploded metallic tube (liner) to compress and inertially confine premagnetized and preheated fusion fuel. The fuel is preheated using a ˜2 kJ laser that must pass through a ˜1.5-3.5-μm-thick polyimide "window" at the target's laser entrance hole (LEH). As the terawatt-class laser interacts with the dense window, laser plasma instabilities (LPIs) can develop, which reduce the preheat energy delivered to the fuel, initiate fuel contamination, and degrade target performance. Cryogenically cooled targets increase the parameter space accessible to MagLIF target designs by allowing nearly 10 times thinner windows to be used for any accessible gas density. Thinner LEH windows reduce the deleterious effects of difficult to model LPIs. The Z Facility's cryogenic infrastructure has been significantly altered to enable compatibility with the premagnetization and fuel preheat stages of MagLIF. The MagLIF cryostat brings the liquid helium coolant directly to the target via an electrically resistive conduit. This design maximizes cooling power while allowing rapid diffusion of the axial magnetic field supplied by external Helmholtz-like coils. A variety of techniques have been developed to mitigate the accumulation of ice from vacuum chamber contaminants on the cooled LEH window, as even a few hundred nanometers of ice would impact laser energy coupling to the fuel region. The MagLIF cryostat has demonstrated compatibility with the premagnetization and preheat stages of MagLIF and the ability to cool targets to liquid deuterium temperatures in approximately 5 min.

  10. Contribution to the development of dry R and W MgB2 superconducting magnets

    International Nuclear Information System (INIS)

    Pasquet, Raphael

    2015-01-01

    Currently, the majority of superconducting magnets, including MRI, are cooled by a bath of liquid helium at atmospheric pressure. Nevertheless, this type of cooling is expensive and imposes significant security constraints for large volumes. For these reasons, the cooling of superconducting magnets is desirable without liquid helium. Cryo-cooler provides dry cooling to 4 K without any liquid helium. However, the power available is low and dry cooling is difficult. In these conditions, it is complicate to use NbTi with dry cooling. But if we increase the operating temperature to 10 K, the power of cryo-cooler increases by a factor of ten. Nevertheless in this case, it is necessary to use of a high critical temperature superconductor. We choose to use MgB 2 R and W conductors because it is relatively low cost but it has the handicap to be sensible at mechanical stress. It is therefore necessary to be careful during their winding to not degrade their superconducting performance. As part of this thesis, we have developed a dry test facility to measure the critical current of MgB 2 R and W conductors as well as mock-ups. To do this, a new type of thermal contact based on aluminum nitride has been developed. In addition to this development, we designed two MgB 2 R and W magnet mock-ups: a solenoid and a double pancake. The double pancake was manufactured (with a new patented winding method) and it has been successfully tested. (author) [fr

  11. Electrochemical investigations of Pu(IV)/Pu(III) redox reaction using graphene modified glassy carbon electrodes and a comparison to the performance of SWCNTs modified glassy carbon electrodes

    International Nuclear Information System (INIS)

    Gupta, Ruma; Gamare, Jayashree; Sharma, Manoj K.; Kamat, J.V.

    2016-01-01

    Highlights: • First report of aqueous electrochemistry of Plutonium on graphene modified electrode. • Graphene is best electrocatalytic material for Pu(IV)/Pu(III) redox couple among the reported modifiers viz. reduced graphene oxide (rGO) and SWCNT’s. • The electrochemical reversibility of Pu(IV)/Pu(III) redox couple improves significantly on graphene modified electrode compared to previously reported rGO & SWCNTs modified electrodes • Donnan interaction between plutonium species and graphene surface offers a possibility for designing a highly sensitive sensor for plutonium • Graphene modified electrode shows higher sensitivity for the determination of plutonium compared to glassy carbon and single walled carbon nanotube modified electrode - Abstract: The work reported in this paper demonstrates for the first time that graphene modified glassy carbon electrode (Gr/GC) show remarkable electrocatalysis towards Pu(IV)/Pu(III) redox reaction and the results were compared with that of single-walled carbon nanotubes modified GC (SWCNTs/GC) and glassy carbon (GC) electrodes. Graphene catalyzes the exchange of current of the Pu(IV)/Pu(III) couple by reducing both the anodic and cathodic overpotentials. The Gr/GC electrode shows higher peak currents (i p ) and smaller peak potential separation (ΔE p ) values than the SWCNTs/GC and GC electrodes. The heterogeneous electron transfer rate constants (k s ), charge transfer coefficients (α) and the diffusion coefficients (D) involved in the electrocatalytic redox reaction were determined. Our observations show that graphene is best electrocatalytic material among both the SWCNTs and GC to study Pu(IV)/Pu(III) redox reaction.

  12. Development of active magnetic bearings and ferrofluid seals toward oil free sodium pumps

    International Nuclear Information System (INIS)

    Sreedhar, B.K.; Kumar, R. Nirmal; Sharma, Prashant; Ruhela, Shivprakash; Philip, John; Sundarraj, S.I.; Chakraborty, N.; Mohana, M.; Sharma, Vijay; Padmakumar, G.; Nashine, B.K.; Rajan, K.K.

    2013-01-01

    Sodium centrifugal pumps employ conventional oil cooled bearings and mechanical seals to support the rotor assembly outside sodium and to seal the cover gas from the atmosphere. Although engineered safety features are incorporated in the design and detailed operational procedures formulated to ensure that no oil contamination of sodium can occur, there have been incidents of oil ingress into sodium. A design variant that eliminates the need for oil in top bearings and seals is therefore a promising option. This paper discusses the work in progress to develop a magnetic bearing and ferrofluid seal combination that can achieve this purpose

  13. Development of an innovative reflector drive mechanism using magnetic repulsion force for 4S reactor

    International Nuclear Information System (INIS)

    Tsuji, K.; Watanabe, M.; Inagaki, H.; Nishikawa, A.; Takahashi, H.; Wakamatsu, M.; Matsumiya, H.; Nishiguchi, Y.

    2001-01-01

    A small sized fast reactor 4S: (Super Safe Small and Simple) which has a core of 10 - 30 years life time is controlled by reflectors. The reflector is required to be risen at very low speed to make up for the reactivity swing during operation. This report shows the development of an innovative reflector drive mechanism using magnetic repulsion force that can move at a several micrometer per one step. This drive mechanism has a passive shut down capability, and can eliminate reflector drive line. (author)

  14. Recent developments in the food quality detected by non-invasive nuclear magnetic resonance technology.

    Science.gov (United States)

    Fan, Kai; Zhang, Min

    2018-02-16

    Nuclear magnetic resonance (NMR) is a rapid, accurate and non-invasive technology and widely used to detect the quality of food, particularly to fruits and vegetables, meat and aquatic products. This review is a survey of recent developments in experimental results for the quality of food on various NMR technologies in processing and storage over the past decade. Following a discussion of the quality discrimination and classification of food, analysis of food compositions and detection of physical, chemical, structural and microbiological properties of food are outlined. Owing to high cost, low detection limit and sensitivity, the professional knowledge involved and the safety issues related to the maintenance of the magnetic field, so far the practical applications are limited to detect small range of food. In order to promote applications for a broader range of foods further research and development efforts are needed to overcome the limitations of NMR in the detection process. The needs and opportunities for future research and developments are outlined.

  15. Design of polymetallic uranium assemblies for the development of single molecule magnets

    International Nuclear Information System (INIS)

    Chatelain, Lucile

    2016-01-01

    The study of actinide chemistry is not only essential for the development of nuclear fuel, nuclear fuel reprocessing or environmental clean up, but also for the understanding of fundamental actinide/ligand interactions and multiple bounding. The magnetic properties of polynuclear actinide molecules are of significant interest to investigate the magnetic communication between the metallic centres. Furthermore, they are highly promising for the design of molecular magnets. Uranium undergoes redox reactions due to a wide range of available oxidation states and easily forms polynuclear assemblies. However, only a few controlled synthetic routes towards these polynuclear uranium assemblies are described in the literature. In this context, the first part of this work was dedicated to the synthesis of oxo/hydroxo uranium clusters from the controlled hydrolysis of tetravalent uranium in the presence of an environmentally relevant ligand. This led to the synthesis of clusters with novel topologies, for which size could be varied as a function of the reaction conditions employed. However, the obtained clusters do not behave as SMM. In order to gain a stronger interaction between metallic centres, the cation-cation interaction was used to rationally design polynuclear uranyl(V) complexes. The isolation of uranyl(V) complexes had been limited in the past by its disproportionation, however, a fine tuning of the organic ligand and reaction conditions finally allowed to stabilise uranyl(V). We used stable uranyl(V) units as building block to form heteronuclear complexes with 3d and 4f metals with polymeric or discrete structures. The study of the magnetic properties of the uranium polynuclear assemblies was carried out and revealed single molecule or chain magnet behaviours with high energy barriers. The uranyl(V) unit was also used as a structural model for the more radioactive neptunium element, allowing the isolation of an isostructural trinuclear neptunyl(V) assembly in

  16. The effect of Nb2O5 dopant on the structural and magnetic properties of MnZn-ferrites

    International Nuclear Information System (INIS)

    Zaspalis, V.T.; Antoniadis, E.; Papazoglou, E.; Tsakaloudi, V.; Nalbandian, L.; Sikalidis, C.A.

    2002-01-01

    In the present work, the role of Nb 2 O 5 additions on the structural and electromagnetic properties of MnZn-ferrites has been investigated. Nb 2 O 5 additions at a concentration of about 200 ppm are found to lower the losses by almost 17%. At higher concentrations Nb 2 O 5 segregates at the grain boundaries, promotes grain growth and affects negatively the microstructure development. At concentrations up to 200 ppm, where a gradual improvement of the magnetic properties is observed, Nb 2 O 5 is found to precipitate together with CaO homogeneously along the grain boundaries and participates in the formation of glassy phases. Those phases act as buffers between the grains, smoothening the transition from one grain to the other. Moreover they also reduce Zn-evaporation at the grain boundary area. Both effects are in favour of low electromagnetic power losses and of high relative magnetic permeabilities

  17. Sensor probes and phantoms for advanced transcranial magnetic stimulation system developments

    Science.gov (United States)

    Meng, Qinglei; Patel, Prashil; Trivedi, Sudhir; Du, Xiaoming; Hong, Elliot; Choa, Fow-Sen

    2015-05-01

    Transcranial magnetic stimulation (TMS) has become one of the most widely used noninvasive method for brain tissue stimulation and has been used as a treatment tool for various neurological and psychiatric disorders including migraine, stroke, Parkinson's disease, dystonia, tinnitus and depression. In the process of developing advanced TMS deep brain stimulation tools, we need first to develop field measurement devices like sensory probes and brain phantoms, which can be used to calibrate the TMS systems. Currently there are commercially available DC magnetic or electric filed measurement sensors, but there is no instrument to measure transient fields. In our study, we used a commercial figure-8 shaped TMS coil to generate transient magnetic field and followed induced field and current. The coil was driven by power amplified signal from a pulse generator with tunable pulse rate, amplitude, and duration. In order to obtain a 3D plot of induced vector electric field, many types of probes were designed to detect single component of electric-field vectors along x, y and z axis in the space around TMS coil. We found that resistor probes has an optimized signal-to-noise ratio (SNR) near 3k ohm but it signal output is too weak compared with other techniques. We also found that inductor probes can have very high output for Curl E measurement, but it is not the E-field distribution we are interested in. Probes with electrical wire wrapped around iron coil can directly measure induced E-field with high sensitivity, which matched computer simulation results.

  18. Replacement and Original Magnet Engineering Options (ROMEOs): A European Seventh Framework Project to Develop Advanced Permanent Magnets Without, or with Reduced Use of, Critical Raw Materials

    Science.gov (United States)

    Mcguiness, P.; Akdogan, O.; Asali, A.; Bance, S.; Bittner, F.; Coey, J. M. D.; Dempsey, N. M.; Fidler, J.; Givord, D.; Gutfleisch, O.; Katter, M.; Le Roy, D.; Sanvito, S.; Schrefl, T.; Schultz, L.; Schwöbl, C.; Soderžnik, M.; Šturm, S.; Tozman, P.; Üstüner, K.; Venkatesan, M.; Woodcock, T. G.; Žagar, K.; Kobe, S.

    2015-06-01

    The rare-earth crisis, which peaked in the summer of 2011 with the prices of both light and heavy rare earths soaring to unprecedented levels, brought about the widespread realization that the long-term availability and price stability of rare earths could not be guaranteed. This triggered a rapid response from manufacturers involved in rare earths, as well as governments and national and international funding agencies. In the case of rare-earth-containing permanent magnets, three possibilities were given quick and serious consideration: (I) increased recycling of devices containing rare earths; (II) the search for new, mineable, rare-earth resources beyond those in China; and (III) the development of high-energy-product permanent magnets with little or no rare-earth content used in their manufacture. The Replacement and Original Magnet Engineering Options (ROMEO) project addresses the latter challenge using a two-pronged approach. With its basis on work packages that include materials modeling and advanced characterization, the ROMEO project is an attempt to develop a new class of novel permanent magnets that are free of rare earths. Furthermore, the project aims to minimize rare-earth content, particularly heavy-rare-earth (HRE) content, as much as possible in Nd-Fe-B-type magnets. Success has been achieved on both fronts. In terms of new, rare-earth-free magnets, a Heusler alloy database of 236,945 compounds has been narrowed down to approximately 20 new compounds. Of these compounds, Co2MnTi is expected to be a ferromagnet with a high Curie temperature and a high magnetic moment. Regarding the reduction in the amount of rare earths, and more specifically HREs, major progress is seen in electrophoretic deposition as a method for accurately positioning the HRE on the surface prior to its diffusion into the microstructure. This locally increases the coercivity of the rather small Nd-Fe-B-type magnet, thereby substantially reducing the dependence on the HREs Dy and

  19. Hard permanent magnet development trends and their application to A.C. machines

    Science.gov (United States)

    Mildrum, H. F.

    1981-01-01

    The physical and magnetic properties of Mn-Al-C, Fe-Cr-Co, and RE-TM (rare earth-transition metal intermetallics) in polymer and soft metal bonded or sintered form are considered for ac circuit machine usage. The manufacturing processes for the magnetic materials are reviewed, and the mechanical and electrical properties of the magnetic materials are compared, with consideration given to the reference Alnico magnet. The Mn-Al-C magnets have the same magnetic properties and costs as Alnico units, operate well at low temperatures, but have poor high temperature performance. Fe-Cr-Co magnets also have comparable cost to Alnico magnets, and operate at high or low temperature, but are brittle, expensive, and contain Co. RE-Co magnets possess a high energy density, operate well in a wide temperature range, and are expensive. Recommendation for exploring the rare-earth alternatives are offered.

  20. Developments in the processing and properties of NdFeb-type permanent magnets

    International Nuclear Information System (INIS)

    Brown, David; Ma, B.-M.; Chen Zhongmin

    2002-01-01

    The composition, microstructure and processing of NdFeB-type permanent magnets are all critical factors for the successful production of high performance magnet components. Three common fabrication routes can be used to categorize these NdFeB-based bulk magnets: sintering, polymer bonding and hot deformation. Generally, the former type of magnet has a high-energy product (30-50 MGOe), full density and a relatively simple shape. Bonded magnets have intermediate energy products (10-18 MGOe), lower density and can be formed into intricate net-shapes. Hot deformed magnets possess full density, intermediate to high-energy products (15-46 MGOe), isotropic or anisotropic properties and have the potential to be formed into net shapes. This article discusses the critical issues of improved magnetic performance, environmental stability, net-shape formability and magnetization behavior for the main categories of NdFeB magnets

  1. Effects of a 4.7 T static magnetic field on fetal development in ICR mice

    International Nuclear Information System (INIS)

    Okazaki, Ryuji; Ootsuyama, Akira; Uchida, Soshi; Norimura, Toshiyuki

    2001-01-01

    In order to determine the effects of a 4.7 T static magnetic field (SMF) on fetal development in mice, we evaluated fetal teratogenesis and endochondral ossification following exposure in utero. Pregnant ICR mice were exposed to a 4.7 T SMF from day 7.5 to 9.5 of gestation in a whole-body dose, and sacrificed on day 18.5 of gestation. We examined with incidence of prenatal death, external malformations and fetal skeletal malformations. There were no significant differences observed in the incidence of prenatal death and/or malformations between SMF-exposed mice and control mice. Further, we evaluated the immunoreactivity for the vascular endothelial growth factor (VEGF), which is implicated in angiogenesis and osteogenesis, in the sternum of fetal mice following magnetic exposure. Our studies also indicated that on day 16.5 of gestation following SMF exposure, the immunoreactivity for VEGF was increased compared to unexposed controls. However, it was decreased in the exposed group compared to the control group on day 18.5 of gestation. DNA and proteoglycan (PG) synthesis were also measured in rabbit costal growth plate chondrocytes in vitro. No significant differences were observed in DNA synthesis between the SMF exposed chondrocytes and the control chondrocytes; however, PG synthesis in SMF exposed chondrocytes increased compared to the controls. Based on these results, we suggest that while SMF exposure promoted the endochondral ossification of chondrocytes, it did not induce any harmful effects on fetal development in ICR mice. (author)

  2. Development of a proof of concept low temperature 4He Superfluid Magnetic Pump

    Science.gov (United States)

    Jahromi, Amir E.; Miller, Franklin K.

    2017-03-01

    We describe the development and experimental results of a proof of concept Superfluid Magnetic Pump in this work. This novel low temperature, no moving part pump can replace the existing bellows-piston driven 4He or 3He-4He mixture compressor/circulators used in various sub Kelvin refrigeration systems such as dilution, Superfluid pulse tube, Stirling, or active magnetic regenerative refrigerators. Due to the superior thermal transport properties of sub-Lambda 4He this pump can also be used as a simple circulator to distribute cooling over large surface areas. Our pump was experimentally shown to produce a maximum flow rate of 440 mg/s (averaged over cycle), 665 mg/s (peak) and produced a maximum pressure difference of 2323 Pa using only the more common isotope of helium, 4He. This pump worked in an ;ideal; thermodynamic state: The experimental results matched with the theoretical values predicted by a computer model. Pump curves were developed to map the performance of this pump. This successful demonstration will enable this novel pump to be implemented in suitable sub Kelvin refrigeration systems.

  3. Multidirectional flow analysis by cardiovascular magnetic resonance in aneurysm development following repair of aortic coarctation

    Directory of Open Access Journals (Sweden)

    Stalder Aurelien F

    2008-06-01

    Full Text Available Abstract Aneurysm formation is a life-threatening complication after operative therapy in coarctation. The identification of patients at risk for the development of such secondary pathologies is of high interest and requires a detailed understanding of the link between vascular malformation and altered hemodynamics. The routine morphometric follow-up by magnetic resonance angiography is a well-established technique. However, the intrinsic sensitivity of magnetic resonance (MR towards motion offers the possibility to additionally investigate hemodynamic consequences of morphological changes of the aorta. We demonstrate two cases of aneurysm formation 13 and 35 years after coarctation surgery based on a Waldhausen repair with a subclavian patch and a Vosschulte repair with a Dacron patch, respectively. Comprehensive flow visualization by cardiovascular MR (CMR was performed using a flow-sensitive, 3-dimensional, and 3-directional time-resolved gradient echo sequence at 3T. Subsequent analysis included the calculation of a phase contrast MR angiography and color-coded streamline and particle trace 3D visualization. Additional quantitative evaluation provided regional physiological information on blood flow and derived vessel wall parameters such as wall shear stress and oscillatory shear index. The results highlight the individual 3D blood-flow patterns associated with the different vascular pathologies following repair of aortic coarctation. In addition to known factors predisposing for aneurysm formation after surgical repair of coarctation these findings indicate the importance of flow sensitive CMR to follow up hemodynamic changes with respect to the development of vascular disease.

  4. A novel highly selective and sensitive detection of serotonin based on Ag/polypyrrole/Cu2O nanocomposite modified glassy carbon electrode.

    Science.gov (United States)

    Selvarajan, S; Suganthi, A; Rajarajan, M

    2018-06-01

    A silver/polypyrrole/copper oxide (Ag/PPy/Cu 2 O) ternary nanocomposite was prepared by sonochemical and oxidative polymerization simple way, in which Cu 2 O was decorated with Ag nanoparticles, and covered by polyprrole (PPy) layer. The as prepared materials was characterized by UV-vis-spectroscopy (UV-vis), FT-IR, X-ray diffraction (XRD), thermo-gravimetric analysis (TGA), scanning electron microscopy (SEM) with EDX, high resolution transmission electron microscopy (HR-TEM) and X-ray photoelectron spectroscopy (XPS). Sensing of serotonin (5HT) was evaluated electrocatalyst using polypyrrole/glassy carbon electrode (PPy/GCE), polypyrrole/copper oxide/glassy carbon electrode (PPy/Cu 2 O/GCE) and silver/polypyrrole/copper oxide/glassy carbon electrode (Ag/PPy/Cu 2 O/GCE). The Ag/PPy/Cu 2 O/GCE was electrochemically treated in 0.1MPBS solution through cyclic voltammetry (CV) and differential pulse voltammetry (DPV). The peak current response increases linearly with 5-HT concentration from 0.01 to 250 µmol L -1 and the detection limit was found to be 0.0124 μmol L -1 . It exhibits high electrocatalytic activity, satisfactory repeatability, stability, fast response and good selectivity against potentially interfering species, which suggests its potential in the development of sensitive, selective, easy-operation and low-cost serotonin sensor for practical routine analyses. The proposed method is potential to expand the possible applied range of the nanocomposite material for detection of various concerned electro active substances. Copyright © 2018 Elsevier B.V. All rights reserved.

  5. Cytochrome C Dynamics at Gold and Glassy Carbon Surfaces Monitored by in Situ Scanning Tunnel Microscopy

    DEFF Research Database (Denmark)

    Andersen, Jens Enevold Thaulov; Møller, Per; Pedersen, Marianne Vind

    1995-01-01

    We have investigated the absorption of cytochrome c on gold and glassy carbon substrates by in situ scanning tunnel microscopy under potentiostatic control of both substrate and tip. Low ionic strength and potential ranges where no Faradaic current flows were used. Cyt c aggregates into flat...... composite structures of about 50 nm lateral extension at gold surfaces. The aggregates evolve in time, and structures resembling individual cyt c molecules can be distinguished in the space between the 50 nm structures. Cyt c aggregates also form at glassy carbon but have a different, unbroken character...... where cyt c both sticks well to the surface and exhibits notable mobility. The observations suggest that characteristic surface specific, internally mobile protein aggregates are formed at both surfaces and that in situ molecular resolution of the STM pictures may have been achieved....

  6. Relaxation of enthalpy fluctuations during sub-T(g) annealing of glassy selenium.

    Science.gov (United States)

    Gulbiten, Ozgur; Mauro, John C; Lucas, Pierre

    2013-06-28

    The relaxation behavior of glass is influenced by the presence of dynamical heterogeneities, which lead to an intrinsically non-monotonic decay of fluctuations in density and enthalpy during isothermal annealing. This is apparently a universal feature of fragile glass forming systems associated with localized spatial variations in relaxation time. Here we present direct experimental observation of the nonmonotonic evolution of enthalpy fluctuations in glassy selenium annealed near room temperature. The nonmonotonic change in the distribution of enthalpy fluctuations measured by heat capacity spectroscopy offers direct evidence for the presence of dynamical heterogeneity in this glass. An enthalpy landscape model of selenium is then used to simulate annealing under identical conditions. The simulation results closely follow the evolution of enthalpy fluctuations observed experimentally. The close match between model and experiment demonstrate that enthalpy and density fluctuations are sources of dynamical heterogeneities in glassy materials.

  7. Connection between NMR and electrical conductivity in glassy chalcogenide fast ionic conductors

    International Nuclear Information System (INIS)

    Kim, K.H.

    1995-01-01

    The work documented in this thesis follows the traditional order. In this chapter a general discussion of ionic conduction and of glassy materials are followed by a brief outline of the experimental techniques for the investigation of fast ionic conduction in glassy materials, including NMR and impedance spectroscopy techniques. A summary of the previous and present studies is presented in the last section of this introductory chapter. The details of the background theory and models are found in the Chapter II, followed by the description of the experimental details in Chapter III. Chapter IV of the thesis describes the experimental results and the analysis of the experimental observations followed by the conclusions in chapter V

  8. Connection between NMR and electrical conductivity in glassy chalcogenide fast ionic conductors

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Kyung -Han [Iowa State Univ., Ames, IA (United States)

    1995-07-07

    The work documented in this thesis follows the traditional order. In this chapter a general discussion of ionic conduction and of glassy materials are followed by a brief outline of the experimental techniques for the investigation of fast ionic conduction in glassy materials, including NMR and impedance spectroscopy techniques. A summary of the previous and present studies is presented in the last section of this introductory chapter. The details of the background theory and models are found in the Chapter II, followed by the description of the experimental details in Chapter III. Chapter IV of the thesis describes the experimental results and the analysis of the experimental observations followed by the conclusions in chapter V.

  9. Language Development and Brain Magnetic Resonance Imaging Characteristics in Preschool Children With Cerebral Palsy.

    Science.gov (United States)

    Choi, Ja Young; Choi, Yoon Seong; Park, Eun Sook

    2017-05-24

    The purpose of this study was to investigate characteristics of language development in relation to brain magnetic resonance imaging (MRI) characteristics and the other contributing factors to language development in children with cerebral palsy (CP). The study included 172 children with CP who underwent brain MRI and language assessments between 3 and 7 years of age. The MRI characteristics were categorized as normal, malformation, periventricular white matter lesion (PVWL), deep gray matter lesion, focal infarct, cortical/subcortical lesion, and others. Neurodevelopmental outcomes such as ambulatory status, manual ability, cognitive function, and accompanying impairments were assessed. Both receptive and expressive language development quotients (DQs) were significantly related to PVWL or deep gray matter lesion severity. In multivariable analysis, only cognitive function was significantly related to receptive language development, whereas ambulatory status and cognitive function were significantly associated with expressive language development. More than one third of the children had a language developmental discrepancy between receptive and expressive DQs. Children with cortical/subcortical lesions were at high risk for this discrepancy. Cognitive function is a key factor for both receptive and expressive language development. In children with PVWL or deep gray matter lesion, lesion severity seems to be useful to predict language development.

  10. The development of the high-tension wire for nuclear fusion superconductive magnet measurement

    International Nuclear Information System (INIS)

    Yoshida, Kiyoshi; Morita, Yohsuke; Yamazaki, Takanori; Watanabe, Kiyoshi; Furusawa, Ken-ichi.

    1987-01-01

    Following on tokamak critical plasma testing device JT-60, experimental fusion reactor JT-100 is being developed. The 6 kV high-tension wire has been developed for use in JT-100 under ultra-low temperature and high radiation environment. Used for superconductive magnet measurement, the wire is inserted in the vacuum vessel, being immersed within the liquid helium. As the insulating material of this wire, polyetherimido was found to be most suitable in the respects of radiation resistance and voltage-withstand property. In an electric wire covered with polyetherimido, which was made in trial, its test in voltage-withstand and bending characteristics at ultra-low temperature showed the wire to be usable for the intended purpose. (Mori, K.)

  11. Development of a Gas Filled Magnet spectrometer coupled with the Lohengrin spectrometer for fission study

    Science.gov (United States)

    Kessedjian, G.; Chebboubi, A.; Faust, H.; Köster, U.; Materna, T.; Sage, C.; Serot, O.

    2013-03-01

    The accurate knowledge of the fission of actinides is necessary for studies of innovative nuclear reactor concepts. The fission yields have a direct influence on the evaluation of the fuel inventory or the reactor residual power after shutdown. A collaboration between the ILL, LPSC and CEA has developed a measurement program on fission fragment distributions at ILL in order to measure the isotopic and isomeric yields. The method is illustrated using the 233U(n,f)98Y reaction. However, the extracted beam from the Lohengrin spectrometer is not isobaric ions which limits the low yield measurements. Presently, the coupling of the Lohengrin spectrometer with a Gas Filled Magnet (GFM) is studied at the ILL in order to define and validate the enhanced purification of the extracted beam. This work will present the results of the spectrometer characterisation, along with a comparison with a dedicated Monte Carlo simulation especially developed for this purpose.

  12. Development of a Gas Filled Magnet spectrometer coupled with the Lohengrin spectrometer for fission study

    Directory of Open Access Journals (Sweden)

    Materna T.

    2013-03-01

    Full Text Available The accurate knowledge of the fission of actinides is necessary for studies of innovative nuclear reactor concepts. The fission yields have a direct influence on the evaluation of the fuel inventory or the reactor residual power after shutdown. A collaboration between the ILL, LPSC and CEA has developed a measurement program on fission fragment distributions at ILL in order to measure the isotopic and isomeric yields. The method is illustrated using the 233U(n,f98Y reaction. However, the extracted beam from the Lohengrin spectrometer is not isobaric ions which limits the low yield measurements. Presently, the coupling of the Lohengrin spectrometer with a Gas Filled Magnet (GFM is studied at the ILL in order to define and validate the enhanced purification of the extracted beam. This work will present the results of the spectrometer characterisation, along with a comparison with a dedicated Monte Carlo simulation especially developed for this purpose.

  13. Diffuse X-ray scattering by glassy crystalline cyclohexanol : preliminary results

    OpenAIRE

    Ceccaldi , D.; Denoyer , F.; Lambert , M.; Szwarc , H.

    1980-01-01

    Diffuse X-ray scattering experiments have been performed to define structural criteria for the glassy crystalline state. When quenching single crystals of the plastic phase of cyclohexanol, the low temperature photographs disclose a structuration of the diffusion patterns that can be assigned to strongly anisotropic short range intermolecular correlations within an orientational disorder. When quenching liquid samples, an amorphous cyclohexanol phase has been discovered.

  14. The effects of carbon dioxide exposure on permeation behavior in silicone rubber and glassy polycarbonates

    Energy Technology Data Exchange (ETDEWEB)

    Jordan, S.M.

    1989-01-01

    Permeation measurements are reported for both rubbery and glassy polymers in the presence of various pure (He, CH{sub 4}, CO{sub 2}, C{sub 2}H{sub 4}) and mixed gas (O{sub 2}/N{sub 2}, CO{sub 2}/CH{sub 4}, He/CO{sub 2}, CO{sub 2}/N{sub 2}) feed streams up to 1000 psia. The polymers studied were silicone rubber and glassy bisphenol-A polycarbonate, tetramethyl polycarbonate and hexafluoro polycarbonate. Large hysteresis was observed in permeation when comparing the pressurization and depressurization responses of the glassy samples in the presence of carbon dioxide above 300 psia exposure pressure. The magnitude of the hysteresis was related to the maximum CO{sub 2} conditioning pressure used. The conditioning treatment resulted in long-lived increases in the permeability of the conditioned films and appeared to be semi-permanent if the conditioning agent was not totally removed. For CO{sub 2}/CH{sub 4} mixed gas feed streams, the conditioning treatment resulted in enhancements in flux without a significant loss in permselectivity. For the silicone rubber sample, no permeability hysteresis was observed. Exchange experiments showed that it was possible to condition a glassy polymer with CO{sub 2} to increase its permeability and to maintain a state of increased permeability even if the CO{sub 2} was replaced by another gas of sufficient solubility such as methane or air. The CO{sub 2} conditioning treatment was not apparent if the CO{sub 2} was replaced by helium without any intervening exposure to vacuum. The inability of helium to detect the effects of the CO{sub 2}-induced conditioning sensed by larger penetrants is discussed and hypothetical explanations for these unexpected results are given.

  15. Effect of thermodynamic history on secondary relaxation in glassy phenolphthalein-dimethyl-ether

    Science.gov (United States)

    Prevosto, D.; Capaccioli, S.; Lucchesi, M.; Rolla, P. A.; Paluch, M.; Pawlus, S.

    2006-03-01

    We present a study of the intermediate secondary relaxation process of phenolphthalein-dimethyl-ether. Though this process is intramolecular in nature, it reveals pronounced pressure dependence. Moreover, its relaxation frequency and intensity exhibit pronounced dependence on the thermal history followed during vitrification. These results suggest that the nonequilibrium nature of the glassy state influences this secondary relaxation principally through the dependence on the specific volume.

  16. Developments for 3D gravity and magnetic modeling in spherical coordinates

    Science.gov (United States)

    Lane, R. J.; Liang, Q.; Chen, C.; Li, Y.

    2012-12-01

    Geoscience Australia (GA) is Australia's Commonwealth Government geoscientific agency. GA performs gravity and magnetic modeling at a range of scales, from broad regional crustal studies with thousands of kilometer lateral extent and tens of kilometer vertical extent, to detailed local studies with kilometer or less lateral extent and meters to hundreds of meters vertical extent. To achieve greater integration and coherence, and to better understand the geological significance of this work, GA are investing in a number of development projects; * Spherical coordinate gravity and magnetic modeling, * Modeling using High Performance Computing facilities, * Utilizing rock property data as an input into the modeling and interpretation of gravity and magnetic data, * Better management of geoscience data and models, and * Visualisation of spatial data in a Virtual Globe format. In collaboration with the Colorado School of Mines (CSM) and the China University of Geosciences (CUG), a capability to model gravity and magnetic data in a spherical coordinate framework is being developed. This will provide more accurate calculations and permit the results to be integrated into a single framework that more realistically reflects the shape of the Earth. Modeling gravity and magnetic data in a spherical coordinate framework is far more computationally intensive than in a Cartesian (rectangular) coordinate framework. To reduce the time required to perform the calculations in a spherical coordinate framework, the modeling software will be deployed by GA on the National Computational Infrastructure (NCI) High Performance Computing (HPC) facility at the Australian National University (ANU). This will also streamline the management of these software relative to the other main option of establishing and maintaining HPC facilities in-house. GA is a participant in the Deep Exploration Technologies Cooperative Research Centre (DET CRC). In combination with this involvement, there is support

  17. Gold nanoparticles directly modified glassy carbon electrode for non-enzymatic detection of glucose

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Gang; Shu, Honghui; Ji, Kai [Ministry-of-Education Key Laboratory for the Green Preparation and Application of Functional Materials, Faculty of Materials Science and Engineering, Hubei University, No. 368 Youyi Avenue, Wuchang, Wuhan 430062 (China); Oyama, Munetaka [Department of Material Chemistry, Graduate School of Engineering, Kyoto University, Nishikyo-ku, Kyoto 615-8520 (Japan); Liu, Xiong [Ministry-of-Education Key Laboratory for the Green Preparation and Application of Functional Materials, Faculty of Materials Science and Engineering, Hubei University, No. 368 Youyi Avenue, Wuchang, Wuhan 430062 (China); He, Yunbin, E-mail: ybhe@hubu.edu.cn [Ministry-of-Education Key Laboratory for the Green Preparation and Application of Functional Materials, Faculty of Materials Science and Engineering, Hubei University, No. 368 Youyi Avenue, Wuchang, Wuhan 430062 (China)

    2014-01-01

    This work describes controllable preparation of gold nanoparticles on glassy carbon electrodes by using the seed mediated growth method, which contains two steps, namely, nanoseeds attachment and nanocrystals growth. The size and the dispersion of gold nanoparticles grown on glassy carbon electrodes could be easily tuned through the growth time based on results of field-emission scanning electron microscopy. Excellent electrochemical catalytic characteristics for glucose oxidation were observed for the gold nanoparticles modified glassy carbon electrodes (AuNPs/GC), resulting from the extended active surface area provided by the dense gold nanoparticles attached. It exhibited a wide linear range from 0.1 mM to 25 mM with the sensitivity of 87.5 μA cm{sup −2} mM{sup −1} and low detection limit down to 0.05 mM for the sensing of glucose. The common interfering species such as chloride ion, ascorbic acid, uric acid and 4-acetamidophenol were verified having no interference effect on the detection of glucose. It is demonstrated that the seed mediated method is one of the facile approaches for fabricating Au nanoparticles modified substrates, which could work as one kind of promising electrode materials for the glucose nonenzymatic sensing.

  18. Potentiometric application of boron- and phosphorus-doped glassy carbon electrodes

    Directory of Open Access Journals (Sweden)

    ZORAN V. LAUSEVIC

    2001-03-01

    Full Text Available Acomparative study was carried out of the potentiometric application of boronand phosphorus-doped and undoped glassy carbon samples prepared at the same heat treatment temperature (HTT 1000°C. The electrochemical activities of the obtained electrode materials were investigated on the example of argentometric titrations. It was found that the electrochemical behaviour of the doped glassy carbon samples are very similar to a Sigri (undoped glassy carbon sample (HTT 2400°C. The experiments showed that the potentiometric response depends on the polarization mode, the nature of the sample, the pretreatment of the electrode surface, and the nature of the supporting electrolyte. The amounts of iodide, bromide, and of chloridewere determined to be 1.27 mg, 0.80 mg and 0.54 mg, respectively, with a maximum relative standard deviation of less than 1.1%. The obtained results are in good agreement with the results of comparative potentiometric titrations using a silver indicator electrode. The titrationmethod was applied to the indirect determination of pyridoxine hydrochloride, i.e., vitamin B6.

  19. Direct electron transfer from glucose oxidase immobilized on a nano-porous glassy carbon electrode

    Energy Technology Data Exchange (ETDEWEB)

    Haghighi, Behzad, E-mail: haghighi@iasbs.ac.ir [Department of Chemistry, Institute for Advanced Studies in Basic Sciences, P.O. Box 45195-1159, Gava Zang, Zanjan (Iran, Islamic Republic of); Tabrizi, Mahmoud Amouzadeh [Department of Chemistry, Institute for Advanced Studies in Basic Sciences, P.O. Box 45195-1159, Gava Zang, Zanjan (Iran, Islamic Republic of)

    2011-11-30

    Highlights: > A direct electron transfer reaction of glucose oxidase was observed on the surface of a nano-porous glassy carbon electrode. > A pair of well-defined and reversible redox peaks was observed at the formal potential of approximately -0.439 V. > The apparent electron transfer rate constant was measured to be 5.27 s{sup -1}. > A mechanism for the observed direct electron transfer reaction was proposed, which consists of a two-electron and a two-proton transfer. - Abstract: A pair of well-defined and reversible redox peaks was observed for the direct electron transfer (DET) reaction of an immobilized glucose oxidase (GOx) on the surface of a nano-porous glassy carbon electrode at the formal potential (E{sup o}') of -0.439 V versus Ag/AgCl/saturated KCl. The electron transfer rate constant (k{sub s}) was calculated to be 5.27 s{sup -1}. The dependence of E{sup o}' on pH indicated that the direct electron transfer of the GOx was a two-electron transfer process, coupled with two-proton transfer. The results clearly demonstrate that the nano-porous glassy carbon electrode is a cost-effective and ready-to-use scaffold for the fabrication of a glucose biosensor.

  20. Dynamics and Geometry of Icosahedral Order in Liquid and Glassy Phases of Metallic Glasses

    Directory of Open Access Journals (Sweden)

    Masato Shimono

    2015-07-01

    Full Text Available The geometrical properties of the icosahedral ordered structure formed in liquid and glassy phases of metallic glasses are investigated by using molecular dynamics simulations. We investigate the Zr-Cu alloy system as well as a simple model for binary alloys, in which we can change the atomic size ratio between alloying components. In both cases, we found the same nature of icosahedral order in liquid and glassy phases. The icosahedral clusters are observed in liquid phases as well as in glassy phases. As the temperature approaches to the glass transition point Tg, the density of the clusters rapidly grows and the icosahedral clusters begin to connect to each other and form a medium-range network structure. By investigating the geometry of connection between clusters in the icosahedral network, we found that the dominant connecting pattern is the one sharing seven atoms which forms a pentagonal bicap with five-fold symmetry. From a geometrical point of view, we can understand the mechanism of the formation and growth of the icosahedral order by using the Regge calculus, which is originally employed to formulate a theory of gravity. The Regge calculus tells us that the distortion energy of the pentagonal bicap could be decreased by introducing an atomic size difference between alloying elements and that the icosahedral network would be stabilized by a considerably large atomic size difference.

  1. Electrochemical pre anodization of glassy carbon electrode and application to determine chloramphenicol

    International Nuclear Information System (INIS)

    Truc, Nguyen Minh; Mortensen, John; Anh, Nguyen Ba Hoai

    2008-01-01

    This paper suggested a method to enhance the performance of carbon electrodes for the determination of chloramphenicol (CAP). The sensitivity and the reproducibility of the carbon electrodes could be enhanced easily by electrochemical pretreatment. Some kinds of carbon material were studied including glassy carbon, graphite carbon and pyrolytic carbon. Numerous kinds of supporting electrolyte have been tried. For glassy carbon electrode, the acidic solution, H 2 SO 4 5 mM, resulted in best performance at pretreated voltage of +2.1V (vs. Ag/ AgCl) in duration of 250 second. However, for graphite and pyrolytic carbon electrodes, the phosphate buffer solution pH 6.0 gave the best performance at +1.7V (vs. Ag/ AgCl) in duration of 20 seconds. The detection limit could be at very low concentration of CAP: 0.8 ng/ ml for glassy carbon electrode, 3.5 ng/ ml for graphite carbon electrode. The method was successful applied to aqua-agriculture water sample and milk sample with simple extraction as well as direct ointment sample analysis. (author)

  2. Graphene oxide-mediated electrochemistry of glucose oxidase on glassy carbon electrodes.

    Science.gov (United States)

    Castrignanò, Silvia; Valetti, Francesca; Gilardi, Gianfranco; Sadeghi, Sheila J

    2016-01-01

    Glucose oxidase (GOD) was immobilized on glassy carbon electrodes in the presence of graphene oxide (GO) as a model system for the interaction between GO and biological molecules. Lyotropic properties of didodecyldimethylammonium bromide (DDAB) were used to stabilize the enzymatic layer on the electrode surface resulting in a markedly improved electrochemical response of the immobilized GOD. Transmission electron microscopy images of the GO with DDAB confirmed the distribution of the GO in a two-dimensional manner as a foil-like material. Although it is known that glassy carbon surfaces are not ideal for hydrogen peroxide detection, successful chronoamperometric titrations of the GOD in the presence of GO with β-d-glucose were performed on glassy carbon electrodes, whereas no current response was detected upon β-d-glucose addition in the absence of GO. The GOD-DDAB-GO system displayed a high turnover efficiency and substrate affinity as a glucose biosensor. The simplicity and ease of the electrode preparation procedure of this GO/DDAB system make it a good candidate for immobilizing other biomolecules for fabrication of amperometric biosensors. © 2015 International Union of Biochemistry and Molecular Biology, Inc.

  3. Development of superparamagnetic high-magnetization C18-functionalized magnetic silica nanoparticles as sorbents for enrichment and determination of methylprednisolone in rat plasma by high performance liquid chromatography.

    Science.gov (United States)

    Yu, Panfeng; Wang, Qi; Zhang, Xifeng; Zhang, Xuesong; Shen, Shun; Wang, Yan

    2010-09-23

    In this study, a novel extraction and enrichment technique based on superparamagnetic high-magnetization C(18)-functionalized magnetic silica nanoparticles (C(18)-MNPs) as sorbents was successfully developed for the determination of methylprednisolone (MP) in rat plasma by high performance liquid chromatography (HPLC). The synthesized silica-coated magnetite modified with chlorodimethyl-n-octadecylsilane was about 320 nm in diameter with strong magnetism and high surface area. It provided an efficient way for extraction and concentration of MP in the samples through hydrophobic interaction by the interior C(18) groups. Moreover, MP adsorbed with C(18)-MNPs could be simply and rapidly isolated through placing a strong magnet on the bottom of container, and then easily eluted from C(18)-MNPs by n-hexane solution. Extraction conditions such as amounts of C(18)-MNPs added, adsorption time and desorption solvent, were investigated. Method validations including linear range, detection limit, precision, and recovery were also studied. The results showed that the proposed method based on C(18)-MNPs was a simple, accurate and high efficient approach for the analysis of MP in the complex plasma samples. Copyright © 2010 Elsevier B.V. All rights reserved.

  4. Design and development of a magnetic device for mesenchymal stem cell retaining in deep targets

    Science.gov (United States)

    Banis, G. C.

    2017-12-01

    This paper focuses on the retaining of mesenchymal stem cells in blood flow conditions using the appropriate magnetic field. Mesenchymal stem cells can be tagged with magnetic nanoparticles and thus, they can be manipulated from distance, through the application of an external magnetic field. In this paper the case of kidney as target of the therapy is being studied.

  5. Fully developed pipe and triangular channel flow measurement using Magnetic Resonance Velocimetry

    Science.gov (United States)

    Baek, Seungchan; Hwang, Wontae

    2017-11-01

    Magnetic resonance velocimetry (MRV) is a non-intrusive flow visualization method which is able to measure the 3 dimensional 3 component (3D3C) mean velocity field in complex geometries, using a healthcare MRI scanner. Since this technique is based on nuclear magnetic resonance (NMR), it is free from optical distortion and does not require tracer particles. Due to these powerful advantages, MRV usage is gradually expanding from biomedical fields to the engineering domain. In this study, we validate the performance of MRV by measuring fully developed pipe flow and compare measured data with time averaged DNS data. We then investigate the overall flow characteristics in a triangular channel with a sharp corner. At the sharp corner, boundary layer effects dominate and the effect of turbulence is reduced. This information has implications for engineering applications such as flow in a turbine blade internal cooling passage at the sharp trailing edge. This research was supported by the Seoul National University Research Grant in 2017, and Doosan Heavy Industries & Construction. (Contract No. 2016900298 and 2017900095).

  6. Development of a magnetic beam guiding system for tumor-specific radiotherapy using heavy, charged particles

    International Nuclear Information System (INIS)

    Haberer, T.

    1994-06-01

    An active, magnetic beam guiding system was developed and tested for the purpose of enhanced and tumor-specific irradiation of irregularly shaped target volumina. Combining intensity-controlled wobbling in rapidly changing magnetic fields with the heavy-ion synchrotron's capacity of fast energy variation achieved a new technique allowing good range modulation. This technique allows the calculated dose distribution to be exactly matched to target contours, and at the same time guarantees best possible quality of the radiation beam, since there is no need for use of mechanical beam shaping members. The components of the scanning system and a specifically designed instrumentation and control concept for this configuration were integrated into the synchrotron's control system, so that there is now a system available offering free selection of beam characteristics combined with energy variation along with the pulsed operation of the accelerator. The system was tested at the biophysical measuring unit of the GSI implementing an elaborated irradiation method at this unit equipped with tools for physico-technical irradiation planning and performance. Methods were designed and tested for optimizing the beam path within a given contour, the optimization taking into account the effects of transmission functions of the scanner components on the results of radiation treatments. (orig.) [de

  7. Development of modular scalable pulsed power systems for high power magnetized plasma experiments

    Science.gov (United States)

    Bean, I. A.; Weber, T. E.; Adams, C. S.; Henderson, B. R.; Klim, A. J.

    2017-10-01

    New pulsed power switches and trigger drivers are being developed in order to explore higher energy regimes in the Magnetic Shock Experiment (MSX) at Los Alamos National Laboratory. To achieve the required plasma velocities, high-power (approx. 100 kV, 100s of kA), high charge transfer (approx. 1 C), low-jitter (few ns) gas switches are needed. A study has been conducted on the effects of various electrode geometries and materials, dielectric media, and triggering strategies; resulting in the design of a low-inductance annular field-distortion switch, optimized for use with dry air at 90 psig, and triggered by a low-jitter, rapid rise-time solid-state Linear Transformer Driver. The switch geometry and electrical characteristics are designed to be compatible with Syllac style capacitors, and are intended to be deployed in modular configurations. The scalable nature of this approach will enable the rapid design and implementation of a wide variety of high-power magnetized plasma experiments. This work is supported by the U.S. Department of Energy, National Nuclear Security Administration. Approved for unlimited release, LA-UR-17-2578.

  8. Mapping fetal brain development in utero using magnetic resonance imaging: the Big Bang of brain mapping.

    Science.gov (United States)

    Studholme, Colin

    2011-08-15

    The development of tools to construct and investigate probabilistic maps of the adult human brain from magnetic resonance imaging (MRI) has led to advances in both basic neuroscience and clinical diagnosis. These tools are increasingly being applied to brain development in adolescence and childhood, and even to neonatal and premature neonatal imaging. Even earlier in development, parallel advances in clinical fetal MRI have led to its growing use as a tool in challenging medical conditions. This has motivated new engineering developments encompassing optimal fast MRI scans and techniques derived from computer vision, the combination of which allows full 3D imaging of the moving fetal brain in utero without sedation. These promise to provide a new and unprecedented window into early human brain growth. This article reviews the developments that have led us to this point, examines the current state of the art in the fields of fast fetal imaging and motion correction, and describes the tools to analyze dynamically changing fetal brain structure. New methods to deal with developmental tissue segmentation and the construction of spatiotemporal atlases are examined, together with techniques to map fetal brain growth patterns.

  9. Development of a hybrid bearing using permanent magnets and piezoelectric actuators

    International Nuclear Information System (INIS)

    Park, Jung-Ho; Ham, Young-Bog; Yun, So-Nam; Lee, Hu-Seung

    2010-01-01

    In this study, a hybrid magnetic bearing with permanent magnets and piezoelectric actuators is investigated. First, in this study, a novel concept in which piezoelectric actuators are used to compensate for low stiffness and damping resulting from the unstable characteristics of a passive magnetic bearing using only permanent magnets is proposed. Secondly, the permanent magnets are optimally arranged through an electromagnetic field analysis. Then, the driving amplifier unit and a prototype radial bearing using the proposed concept are fabricated. Finally, basic characteristics, such as the results of an impact test and a rotational runout test with constant speed are investigated and discussed, and experiments using PID control method are conducted.

  10. Development of a magnetic lab-on-a-chip for point-of-care sepsis diagnosis

    International Nuclear Information System (INIS)

    Schotter, Joerg; Shoshi, Astrit; Brueckl, Hubert

    2009-01-01

    We present design criteria, operation principles and experimental examples of magnetic marker manipulation for our magnetic lab-on-a-chip prototype. It incorporates both magnetic sample preparation and detection by embedded GMR-type magnetoresistive sensors and is optimized for the automated point-of-care detection of four different sepsis-indicative cytokines directly from about 5 μl of whole blood. The sample volume, magnetic particle size and cytokine concentration determine the microfluidic volume, sensor size and dimensioning of the magnetic gradient field generators. By optimizing these parameters to the specific diagnostic task, best performance is expected with respect to sensitivity, analysis time and reproducibility.

  11. Development of a magnetic lab-on-a-chip for point-of-care sepsis diagnosis

    Energy Technology Data Exchange (ETDEWEB)

    Schotter, Joerg [Austrian Research Centers GmbH-ARC, Nano-System-Technologies, Donau-City-Strasse 1, Tech Gate Vienna 2. OG, 1220 Vienna (Austria)], E-mail: Joerg.Schotter@arcs.ac.at; Shoshi, Astrit; Brueckl, Hubert [Austrian Research Centers GmbH-ARC, Nano-System-Technologies, Donau-City-Strasse 1, Tech Gate Vienna 2. OG, 1220 Vienna (Austria)

    2009-05-15

    We present design criteria, operation principles and experimental examples of magnetic marker manipulation for our magnetic lab-on-a-chip prototype. It incorporates both magnetic sample preparation and detection by embedded GMR-type magnetoresistive sensors and is optimized for the automated point-of-care detection of four different sepsis-indicative cytokines directly from about 5 {mu}l of whole blood. The sample volume, magnetic particle size and cytokine concentration determine the microfluidic volume, sensor size and dimensioning of the magnetic gradient field generators. By optimizing these parameters to the specific diagnostic task, best performance is expected with respect to sensitivity, analysis time and reproducibility.

  12. Development of a magnetic lab-on-a-chip for point-of-care sepsis diagnosis

    Science.gov (United States)

    Schotter, Joerg; Shoshi, Astrit; Brueckl, Hubert

    2009-05-01

    We present design criteria, operation principles and experimental examples of magnetic marker manipulation for our magnetic lab-on-a-chip prototype. It incorporates both magnetic sample preparation and detection by embedded GMR-type magnetoresistive sensors and is optimized for the automated point-of-care detection of four different sepsis-indicative cytokines directly from about 5 μl of whole blood. The sample volume, magnetic particle size and cytokine concentration determine the microfluidic volume, sensor size and dimensioning of the magnetic gradient field generators. By optimizing these parameters to the specific diagnostic task, best performance is expected with respect to sensitivity, analysis time and reproducibility.

  13. Study and Developement of Compact Permanent Magnet Hall Thrusters for Future Brazillian Space Missions

    Science.gov (United States)

    Ferreira, Jose Leonardo; Martins, Alexandre; Cerda, Rodrigo

    2016-07-01

    The Plasma Physics Laboratory of UnB has been developing a Permanent Magnet Hall Thruster (PHALL) for the UNIESPAÇO program, part of the Space Activities Program conducted by AEB- The Brazillian Space Agency since 2004. Electric propulsion is now a very successful method for primary and secondary propulsion systems. It is essential for several existing geostationary satellite station keeping systems and for deep space long duration solar system missions, where the thrusting system can be designed to be used on orbit transfer maneuvering and/or for satellite attitude control in long term space missions. Applications of compact versions of Permanent Magnet Hall Thrusters on future brazillian space missions are needed and foreseen for the coming years beginning with the use of small divergent cusp field (DCFH) Hall Thrusters type on CUBESATS ( 5-10 kg , 1W-5 W power consumption) and on Micro satellites ( 50- 100 kg, 10W-100W). Brazillian (AEB) and German (DLR) space agencies and research institutions are developing a new rocket dedicated to small satellite launching. The VLM- Microsatellite Launch Vehicle. The development of PHALL compact versions can also be important for the recently proposed SBG system, a future brazillian geostationary satellite system that is already been developed by an international consortium of brazillian and foreign space industries. The exploration of small bodies in the Solar System with spacecraft has been done by several countries with increasing frequency in these past twenty five years. Since their historical beginning on the sixties, most of the Solar System missions were based on gravity assisted trajectories very much depended on planet orbit positioning relative to the Sun and the Earth. The consequence was always the narrowing of the mission launch window. Today, the need for Solar System icy bodies in situ exploration requires less dependence on gravity assisted maneuvering and new high precision low thrust navigation methods

  14. Magnetic Approaches to Measuring and Mitigating Airborne Particulate Pollution

    Science.gov (United States)

    Maher, B.

    2014-12-01

    Human exposure to airborne particulate matter (PM) generates adverse human health impacts at all life stages from the embryonic to the terminal, including damage to respiratory and cardiovascular health, and neurodevelopment and cognitive function. Detailed understanding of the causal links between PM exposure and specific health impacts, and possible means to reduce PM exposure require knowledge of PM concentrations, compositions and sources at the fine-scale; i.e. beyond the current resolution of spatially-sparse conventional PM monitoring, non-unique elemental analyses, or poorly-validated PM modelling. Magnetically-ordered iron oxide minerals appear to be a ubiquitous component of urban PM. These minerals derive partly from the presence of iron impurities in fuels, which form, upon combustion, a non-volatile residue, often dominated by magnetite, within glassy, spherical condensates. Iron-rich, magnetic PM also arises from abrasion from vehicle components, including disk brakes, and road dust. The ubiquity and diversity of these magnetic PM phases, and the speed and sensitivity of magnetic analyses (down to trace concentrations), makes possible rapid, cost-effective magnetic characterization and quantification of PM, a field of study which has developed rapidly across the globe over the last 2 decades. Magnetic studies of actively-sampled PM, on filters, and passively-sampled PM, on tree leaves and other depositional surfaces, can be used to: monitor and map at high spatial resolution ambient PM concentrations; address the controversial issue of the efficacy of PM capture by vegetation; and add a new, discriminatory dimension to PM source apportionment.

  15. Quantitative magnetic resonance imaging and studies of degenerative diseases of the developing human brain

    International Nuclear Information System (INIS)

    Caviness, V.S. Jr.; Phil, D.; Filipek, P.A.; Kennedy, D.N.

    1992-01-01

    The Rett syndrome is a progressive disorder which is associated with regression of psychomotor development and precipitous deceleration of brain growth during the first year of life. General histopathological surveys in postmortem specimens have identified degeneration of subpopulations of neurons of the nigrostriatal system but no other evidence of degenerative process. Magnetic resonance imaging-based morphometry may usefully guide application of rigorous but demanding quantitative histologic search for evidence of neuronal degeneration. The volumes of the principal set of cortical and nuclear structures of principal interest in the disorder may be measured by currently avaiable MRI-based methods. Opimized levels of precision now allow detection of volumetric changes over time in the same brain of approximately 10% at the 95% confidence level. (author)

  16. Development Of Radioimmunoassay For Prolactin HORMONE Using Solid Phase Magnetic Particles

    International Nuclear Information System (INIS)

    SHAFIK, H.M.; MEHANY, N.L.

    2009-01-01

    The preparation and development of primary reagents of prolactin (PRL) radioimmunoassay (RIA) technique using solid phase magnetic particles with low cost is considered to be the main objective of the present study. The production of polyclonal antibodies was undertaken by immunizing four female New-Zealand rabbits through primary injection and four booster doses subcutaneously. The preparation of 125 I-prolactin radiotracer was carried out using chloramine-T. The preparation of standard prolactin was undertaken by preparing stock standard solution of prolactin and diluted with assay buffer. Activation and coupling of low magnetizable particles with the purified anti-PRL was carried out. Optimization and validation of the assay were carried out. The results obtained provide a highly sensitive, specific and accurate RIA system of PRL. In conclusion, this assay could be used in diagnosis of galactorrhea, prolactinoma, visual impairment and diagnosis of infertility in males and females.

  17. Recent developments in optimal experimental designs for functional magnetic resonance imaging.

    Science.gov (United States)

    Kao, Ming-Hung; Temkit, M'hamed; Wong, Weng Kee

    2014-07-28

    Functional magnetic resonance imaging (fMRI) is one of the leading brain mapping technologies for studying brain activity in response to mental stimuli. For neuroimaging studies utilizing this pioneering technology, there is a great demand of high-quality experimental designs that help to collect informative data to make precise and valid inference about brain functions. This paper provides a survey on recent developments in experimental designs for fMRI studies. We briefly introduce some analytical and computational tools for obtaining good designs based on a specified design selection criterion. Research results about some commonly considered designs such as blocked designs, and m-sequences are also discussed. Moreover, we present a recently proposed new type of fMRI designs that can be constructed using a certain type of Hadamard matrices. Under certain assumptions, these designs can be shown to be statistically optimal. Some future research directions in design of fMRI experiments are also discussed.

  18. Fetal magnetic resonance imaging of the brain: technical considerations and normal brain development

    Energy Technology Data Exchange (ETDEWEB)

    Huisman, Thierry A.G.M.; Kubik-Huch, Rahel; Marincek, Borut [Institute of Diagnostic Radiology, University Hospital Zurich, 8091 Zurich (Switzerland); Martin, Ernst [Department of Neuroradiology and Magnetic Resonance, University Children' s Hospital, 8091 Zurich (Switzerland)

    2002-08-01

    Fetal MRI examines non-invasively the unborn fetus. Ultrafast MRI sequences effectively suppress fetal motion. Multiple case reports and studies have shown that fetal MRI is particularly helpful in the evaluation of the central nervous system. The high contrast-to-noise ratio, the high spatial resolution, the multiplanar capabilities, the large field of view and the simultaneous visualisation of fetal and maternal structures have proven to be advantageous. Fetal MRI is particularly helpful in the evaluation of the normal and pathological development of the brain. Despite the fact that no side effects have been reported or are to be expected, the use of MRI during pregnancy is still limited to the second and third trimester of pregnancy. Magnetic resonance imaging contrast media are not to be used as it passes the placenta. Ultrasound remains the primary screening modality for fetal pathology; fetal MRI can serve as an adjunct or second-line imaging modality. (orig.)

  19. Fetal magnetic resonance imaging of the brain: technical considerations and normal brain development

    International Nuclear Information System (INIS)

    Huisman, Thierry A.G.M.; Kubik-Huch, Rahel; Marincek, Borut; Martin, Ernst

    2002-01-01

    Fetal MRI examines non-invasively the unborn fetus. Ultrafast MRI sequences effectively suppress fetal motion. Multiple case reports and studies have shown that fetal MRI is particularly helpful in the evaluation of the central nervous system. The high contrast-to-noise ratio, the high spatial resolution, the multiplanar capabilities, the large field of view and the simultaneous visualisation of fetal and maternal structures have proven to be advantageous. Fetal MRI is particularly helpful in the evaluation of the normal and pathological development of the brain. Despite the fact that no side effects have been reported or are to be expected, the use of MRI during pregnancy is still limited to the second and third trimester of pregnancy. Magnetic resonance imaging contrast media are not to be used as it passes the placenta. Ultrasound remains the primary screening modality for fetal pathology; fetal MRI can serve as an adjunct or second-line imaging modality. (orig.)

  20. Fetal magnetic resonance imaging of the brain: technical considerations and normal brain development.

    Science.gov (United States)

    Huisman, Thierry A G M; Martin, Ernst; Kubik-Huch, Rahel; Marincek, Borut

    2002-08-01

    Fetal MRI examines non-invasively the unborn fetus. Ultrafast MRI sequences effectively suppress fetal motion. Multiple case reports and studies have shown that fetal MRI is particularly helpful in the evaluation of the central nervous system. The high contrast-to-noise ratio, the high spatial resolution, the multiplanar capabilities, the large field of view and the simultaneous visualisation of fetal and maternal structures have proven to be advantageous. Fetal MRI is particularly helpful in the evaluation of the normal and pathological development of the brain. Despite the fact that no side effects have been reported or are to be expected, the use of MRI during pregnancy is still limited to the second and third trimester of pregnancy. Magnetic resonance imaging contrast media are not to be used as it passes the placenta. Ultrasound remains the primary screening modality for fetal pathology; fetal MRI can serve as an adjunct or second-line imaging modality.

  1. Development of a Nb 3Sn multifilamentary wire for accelerator magnet applications

    Science.gov (United States)

    Durante, M.; Bredy, P.; Devred, A.; Otmani, R.; Reytier, M.; Schild, T.; Trillaud, F.

    2001-05-01

    CEA/Saclay and Alstom/MSA have carried out a program to develop a Nb 3Sn multifilamentary wire for accelerator magnet applications relying on the internal-tin process. The main wire specifications are: an overall diameter of 0.825 mm, a critical current larger than 405 A at 4.2 K and 7 T, hysteresis losses lower than 450 mJ/cm 3 for a±3 T trapezoidal cycle, and a copper-to-non-copper ratio greater than 1. The last phase of the optimization program was based on four different strands and we present here the results of the characterization tests, including residual resistivity ratio, critical current and AC loss measurements.

  2. Development of DC active filter for high magnetic field stable power supply

    International Nuclear Information System (INIS)

    Wang Lei; Liu Xiaoning

    2008-01-01

    The DC active filter (DAF), with very low current ripple, of the stable power supply system of high magnetic field device is developed by using the PWM and parallel active power filter technique. Due to the PWM control technique, the required DAF current can be obtained and the current ripple can be compensated by means of monitoring the load voltage, and the current ripple becomes very low by adjusting the load voltage. The simulation and analysis show that this system can respond to the reference quickly and is effective in suppressing the harmonics, especially the low-order harmonics. The feasibility of the proposed scheme is proved on the equipment built in the laboratory. (authors)

  3. Quantitative magnetic resonance imaging and studies of degenerative diseases of the developing human brain

    Energy Technology Data Exchange (ETDEWEB)

    Caviness, V.S. Jr. (Massachusetts General Hospital, Boston, MA (United States)); Phil, D.; Filipek, P.A.; Kennedy, D.N.

    1992-05-01

    The Rett syndrome is a progressive disorder which is associated with regression of psychomotor development and precipitous deceleration of brain growth during the first year of life. General histopathological surveys in postmortem specimens have identified degeneration of subpopulations of neurons of the nigrostriatal system but no other evidence of degenerative process. Magnetic resonance imaging-based morphometry may usefully guide application of rigorous but demanding quantitative histologic search for evidence of neuronal degeneration. The volumes of the principal set of cortical and nuclear structures of principal interest in the disorder may be measured by currently avaiable MRI-based methods. Opimized levels of precision now allow detection of volumetric changes over time in the same brain of approximately 10% at the 95% confidence level. (author).

  4. Development of Position-Sensitive Magnetic Calorimeters for X-Ray Astronomy

    Science.gov (United States)

    Bandler, SImon; Stevenson, Thomas; Hsieh, Wen-Ting

    2011-01-01

    Metallic magnetic calorimeters (MMC) are one of the most promising devices to provide very high energy resolution needed for future astronomical x-ray spectroscopy. MMC detectors can be built to large detector arrays having thousands of pixels. Position-sensitive magnetic (PoSM) microcalorimeters consist of multiple absorbers thermally coupled to one magnetic micro calorimeter. Each absorber element has a different thermal coupling to the MMC, resulting in a distribution of different pulse shapes and enabling position discrimination between the absorber elements. PoSMs therefore achieve the large focal plane area with fewer number of readout channels without compromising spatial sampling. Excellent performance of PoSMs was achieved by optimizing the designs of key parameters such as the thermal conductance among the absorbers, magnetic sensor, and heat sink, as well as the absorber heat capacities. Micro fab ri - cation techniques were developed to construct four-absorber PoSMs, in which each absorber consists of a two-layer composite of bismuth and gold. The energy resolution (FWHM full width at half maximum) was measured to be better than 5 eV at 6 keV x-rays for all four absorbers. Position determination was demonstrated with pulse-shape discrimination, as well as with pulse rise time. X-ray microcalorimeters are usually designed to thermalize as quickly as possible to avoid degradation in energy resolution from position dependence to the pulse shapes. Each pixel consists of an absorber and a temperature sensor, both decoupled from the cold bath through a weak thermal link. Each pixel requires a separate readout channel; for instance, with a SQUID (superconducting quantum interference device). For future astronomy missions where thousands to millions of resolution elements are required, having an individual SQUID readout channel for each pixel becomes difficult. One route to attaining these goals is a position-sensitive detector in which a large continuous or

  5. Development of Automotive Permanent Magnet Alternator with Fully Controlled AC/DC Converter

    Directory of Open Access Journals (Sweden)

    Tareq S. El-Hasan

    2018-01-01

    Full Text Available This paper proposes the design of a three-phase axial flux permanent magnet alternator (AFPMA that is characterized with an air-cored stator and two-rotor (ACSTR configuration. The AFPMA is harnessed with fully controlled AC/DC converter using six bridge Insulated Gate Bipolar Transistor (IGBTs capable to deliver a constant DC output power as an attempt to replace the Lundell alternator for automotive applications. First, the design methodology and analysis of the AFPMA is introduced. The most effective parameters, such as rotor diameter, magnet thickness, number of turns, and winding thickness are determined. A smart digital control which facilitates the comparison between the magnitudes of the three-phase input signals instead of finding the zero crossing points is developed. Moreover, custom design comparators are specially designed and developed to generate adaptive signals that are fed into an Arduino Uno microcontroller. Accordingly, the Arduino generates the timely precise pulses that are necessary to maintain the appropriate triggering of the IGBTs. This technique allows the IGBTs to conduct in an adaptive manner to overcome the problem of asymmetrical voltage outputs from the AFPM alternator. The system is also capable of handling the variation in the speed of the AFPMA via the rigor code in Arduino that detects the change in the supply frequency and voltages in a real time process. The system is first analyzed via simulations using MATLAB/Simulink and then experimentally validated at certain speed and loading conditions. The preliminary tests results indicate that such system is capable to provide an efficient solution to satisfy automotive electric power demands.

  6. Correlation between exposure to magnetic fields and embryonic development in the first trimester.

    Directory of Open Access Journals (Sweden)

    Xiu-Juan Su

    Full Text Available OBJECTIVE: To explore the correlation between maternal magnetic field (MF exposure in daily life and embryonic development. METHODS: A cross-sectional study was conducted among 149 pregnant women who were seeking induced abortion of unwanted pregnancies. Participating women were asked to wear an EMDEX Lite magnetic field meter for a 24-h period to obtain MF exposure level within 4 weeks following the abortion. Embryonic bud and sac lengths were measured through B-mode ultrasound before the surgical abortion. Embryo sections were prepared and examined for histological changes, and the apoptosis status of the deciduas was examined using the TUNEL apoptosis assay. RESULTS: Embryonic bud length was inversely associated with maternal daily MF exposure level; the association was statistically significant at the time-weighted-average and 75th percentile of MF exposure levels, with coefficients of -3.09 (P = 0.0479 and -3.07 (P = 0.0228, respectively. Logistic regression for examining the risk of higher MF exposure indicated that women with her 75th percentile of daily MF measurements ≥0.82 mG had a 3.95-fold risk of having a fetus with a shorter embryonic bud length than those whose daily MF exposure were <0.82 mG. MF exposure was associated with a higher degree of apoptosis, but the association was not statistically significant. We failed to find a statistical correlation between MF exposure and embryonic sac length and histological changes in the first trimester. CONCLUSION: Prenatal MF exposure may have an adverse effect on embryonic development.

  7. A Generic Model for Prediction of Separation Performance of Olefin/Paraffin Mixture by Glassy Polymer Membranes

    Directory of Open Access Journals (Sweden)

    A.A. Ghoreyshi

    2008-02-01

    Full Text Available The separation of olefin/paraffin mixtures is an important process in petrochemical industries, which is traditionally performed by low temperature distillation with a high-energy consumption, or complex extractive distillationand adsorption techniques. Membrane separation process is emerging as an alternative for traditional separation processes with respect to low energy and simple operation. Investigations made by various researchers on polymeric membranes it is found that special glassy polymers render them as suitable materials for olefin/paraffin mixture separation. In this regard, having some knowledge on the possible transport mechanism of these processes would play a significant role in their design and applications. In this study, separation behavior of olefin/paraffin mixtures through glassy polymers was modeled by three different approaches: the so-called dual transport model, the basic adsorption-diffusion theory and the general Maxwell-Stefan formulation. The systems chosen to validate the developed transport models are separation of ethane-ethylene mixture by 6FDA-6FpDA polyimide membrane and propane-propylene mixture by 6FDA-TrMPD polyimide membrane for which the individual sorption and permeation data are available in the literature. Acritical examination of dual transport model shows that this model fails clearly to predict even the proper trend for selectivities. The adjustment of pemeabilities by accounting for the contribution of non-selective bulk flow in the transport model introduced no improvement in the predictability of the model. The modeling results based on the basic adsorption-diffusion theory revealed that in this approach only using mixed permeability data, an acceptable result is attainable which fades out the advantages of predictibility of multicomponent separation performance from pure component data. Finally, the results obtained from the model developed based on Maxwell-Stefan formulation approach show a

  8. A sigma-model approach to glassy dynamics

    Indian Academy of Sciences (India)

    reparametrizations are analogous to uniform spin rotations while local time re- parametrizations describe the spin waves (fluctuations on the uniform solution). An important feature of this scenario is that a critical-like dynamical two-time dependent correlation length develops. This framework allowed us to predict several ...

  9. Thermodynamics of Glassy Systems: Glasses, Spin Glasses and Optimization

    NARCIS (Netherlands)

    Leuzzi, L.

    2002-01-01

    After a long, self-standing dominance of Newtonian reductionism, at the beginning of the nineteenth century, with the birth of thermodynamics, a new approach began to develop to the study of nature. Indeed, the prediction of the behaviour of a macroscopic material through the knowledge of all the

  10. Development of Thermoelectric and Permanent Magnet Nanoparticles for Clean Energy Applications

    Science.gov (United States)

    Nguyen, Phi-Khanh

    The global trend towards energy efficiency and environmental sustainability has generated a strong demand for clean energy technologies. Among the many energy solutions, the work in this dissertation contributes to two strategic goals: the reduction of fuel consumption in the transportation sector, and the increase of domestic wind power capacity. The key barriers to achieving these goals are materials challenges. Automobiles can be made more efficient by thermoelectric conversion of waste heat from the engine into electricity that can be used to power electrical components in the vehicle. Vehicles can forego petroleum fuel altogether by using electric or hybrid motors. Unfortunately, the conversion efficiency of current thermoelectric technology is too low to be considered economically feasible, and the permanent magnets used in electric vehicle motors and wind turbine generators require critical rare-earth elements that are economically unstable (often referred to as the "rare-earth crisis"). In order to combat these challenges, a "spark erosion" technique was utilized for producing nanoparticles that improve thermoelectric efficiency and contribute to the development of electromotors that do not require rare-earths. In Chapter 2 of this dissertation, I describe the utilization of spark erosion for producing high-quality thermoelectric nanoparticles at a remarkably high rate and with enhanced thermoelectric properties. The technique was employed to synthesize p-type bismuth-antimony telluride (BST) and n-type skutterudite nanoparticles, using a relatively small laboratory apparatus, with low energy consumption. The compacted BST nanocomposite samples made from these nanoparticles exhibit a well-defined, 20--50 nm size nanograin microstructure, and show an enhanced Figure of merit, ZT, of 1.36 at 360 K due to a reduction in lattice thermal conductivity. The skutterudite nanocomposites also show reduced thermal conductivity but still require enhancement in the

  11. Adsorptive stripping voltammetry for simultaneous determination of hydrochlorothiazide and triamterene in hemodialysis samples using a multi-walled carbon nanotube-modified glassy carbon electrode.

    Science.gov (United States)

    Hudari, Felipe Fantinato; Souza, João Carlos; Zanoni, Maria Valnice Boldrin

    2018-03-01

    Hemodialysis is the most commonly used method for the treatment of chronic kidney disease. In this procedure, some patients use diuretics to control weight gain and blood pressure. In this work, a voltammetric sensor based on a glassy carbon electrode modified with carbon nanotubes (GCE/MWCNT) is described for the simultaneous determination of the diuretics hydrochlorothiazide (HCT) and triamterene (TRT). The oxidation of the diuretics on the GCE/MWCNT surface was observed at 1.01 and 1.17V for HCT and TRT, respectively, allowing simultaneous determination, which was not possible with the unmodified glassy carbon electrode. The GCE/MWCNT electrode provided 6-fold and 10-fold gains in anode peak intensity for HCT and TRT, respectively, compared to the unmodified electrode. After optimization of the conditions (pH, accumulation time, and accumulation potential), analytical curves were constructed for the analytes in the range from 1.0 × 10 -7 to 2.0 × 10 -5 molL -1 . The detection limits for HCT and TRT were 2.8 × 10 -8 and 2.9 × 10 -8 molL -1 , respectively. A high performance liquid chromatography method with diode array detection was also developed for the determination of HCT and TRT in hemodialysis samples, for comparison with the electroanalytical method. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. Developing Criteria for Lumbar Spine Magnetic Resonance Imaging (MRI) Using RAND Appropriateness Method (RAM)

    International Nuclear Information System (INIS)

    Keshtkaran, Ali; Bagheri, Mohammad Hadi; Ostovar, Rahim; Salari, Hedayat; Farokhi, Majid Reza; Esfandiari, Atefeh; Yousefimanesh, Hossein

    2012-01-01

    Studies show that a large proportion of healthcare offered may be inappropriate or unnecessary. Magnetic resonance imaging (MRI) is a new and expensive diagnostic technology which has been increasingly used all over the world. Moreover, this trend has been more rapidly increasing in Iran. Low back pain is a common disorder all over the world and MRI technique is one of the several ways to assess its cause. The present study aims to develop scenarios for lumbar spine MRI. In the present study, the RAND Appropriateness Method (RAM) was used in order to reach consensus regarding developing scenarios for lumbar spine MRI. We generated scenarios from valid clinical guidelines as well as the experts’ opinion. The panel members included nine specialists from various medical specialties that had scored scenarios in two rounds, the first of which was without interaction, while the second one was with interaction. We extracted 97 scenarios for the lumbar spine MRI in the scenario extracting phase of the study and the panel members added 18 scenarios. After implementation of two rounds, the scenarios were categorized into three ranges. Sixty seven (58%) of the scenarios were considered as appropriate, 45 (39%) as uncertain, and three (2.6%) as inappropriate. RAM is useful for identifying stakeholder views in settings with limited resources. Since RAM has precise instructions for consensus developing, a large number of scenarios were considered as uncertain. Therefore, more research has to be conducted on the issue

  13. Radiation-Induced Alterations in Mouse Brain Development Characterized by Magnetic Resonance Imaging

    International Nuclear Information System (INIS)

    Gazdzinski, Lisa M.; Cormier, Kyle; Lu, Fred G.; Lerch, Jason P.; Wong, C. Shun; Nieman, Brian J.

    2012-01-01

    Purpose: The purpose of this study was to identify regions of altered development in the mouse brain after cranial irradiation using longitudinal magnetic resonance imaging (MRI). Methods and Materials: Female C57Bl/6 mice received a whole-brain radiation dose of 7 Gy at an infant-equivalent age of 2.5 weeks. MRI was performed before irradiation and at 3 time points following irradiation. Deformation-based morphometry was used to quantify volume and growth rate changes following irradiation. Results: Widespread developmental deficits were observed in both white and gray matter regions following irradiation. Most of the affected brain regions suffered an initial volume deficit followed by growth at a normal rate, remaining smaller in irradiated brains compared with controls at all time points examined. The one exception was the olfactory bulb, which in addition to an early volume deficit, grew at a slower rate thereafter, resulting in a progressive volume deficit relative to controls. Immunohistochemical assessment revealed demyelination in white matter and loss of neural progenitor cells in the subgranular zone of the dentate gyrus and subventricular zone. Conclusions: MRI can detect regional differences in neuroanatomy and brain growth after whole-brain irradiation in the developing mouse. Developmental deficits in neuroanatomy persist, or even progress, and may serve as useful markers of late effects in mouse models. The high-throughput evaluation of brain development enabled by these methods may allow testing of strategies to mitigate late effects after pediatric cranial irradiation.

  14. Applications of Magnetic Water Technology in Farming and Agriculture Development: A Review of Recent Advances

    OpenAIRE

    Yadollahpour Ali; Rashidi Samaneh; Fatemeh Kavakebian

    2014-01-01

    Magnetic water treatment (MWT) techniques have shown promising potentials in different areas specially agriculture. Safety, compatibility and simplicity, environmentally friendliness, low operating cost and not proven harmful effects are the main advantages of electromagnetic field (EMF) over conventional methods for water treatment. Magnetized or magnetic water (MW) possesses unique physical and chemical characteristics making it a multi-purpose compound with potential benefits in medical tr...

  15. Development and applications of NMR [nuclear magnetic resonance] in low fields and zero field

    International Nuclear Information System (INIS)

    Bielecki, A.

    1987-05-01

    This dissertation is about nuclear magnetic resonance (NMR) spectroscopy in the absence of applied magnetic fields. NMR is usually done in large magnetic fields, often as large as can be practically attained. The motivation for going the opposite way, toward zero field, is that for certain types of materials, particularly powdered or polycrystalline solids, the NMR spectra in zero field are easier to interpret than those obtained in high field. 92 refs., 60 figs., 1 tab

  16. Development of a screening assay for ligands to the estrogen receptor based on magnetic microparticles and LC-MS

    Science.gov (United States)

    Choi, Yongsoo; van Breemen, Richard B.

    2009-01-01

    A high throughput screening assay for the identification of ligands to pharmacologically significant receptors was developed based on magnetic particles containing immobilized receptors followed by liquid chromatography—mass spectrometry (LC-MS). This assay is suitable for the screening of complex mixtures such as botanical extracts. For proof-of-principle, estrogen receptor-α (ER-α) and ER-β were immobilized on magnetic particles functionalized with aldehyde or carboxylic acid groups. Alternatively, biotinylated ER was immobilized onto streptavidin-derivatized magnetic particles. The ER that was immobilized using the streptavidin-biotin chemistry showed higher activity than that immobilized on aldehyde or carboxylic acid functionalized magnetic particles. Immobilized ER was incubated with extracts of Trifolium pratense L. (red clover) or Humulus lupulus L. (hops). As a control for non-specific binding, each botanical extract was incubated with magnetic particles containing no ER. After magnetic separation of the particles containing bound ligands from the unbound components in the extract, the particles were washed, ligands were released using methanol, and then the ligands were identified using LC-MS. The estrogens genistein and daidzein were identified in the red clover extract, and the estrogen 8-prenylnaringenin was identified in the hop extract. These screening results are consistent with those obtained using previous screening approaches. PMID:18220538

  17. Developments in Understanding Stability as Applied to Magnetic Levitated Launch Assist

    Science.gov (United States)

    Gering, James A.

    2002-01-01

    Magnetic levitation is a promising technology, with the potential of constituting the first stage of a third generation space transportation system. Today, the Space Shuttle burns on the order of one million pounds of solid rocket propellant to bring the orbiter and external tank to nearly Mach 1 (1,000 kph). Imagine the reductions in launch vehicle weight, complexity and risk if an aerospace vehicle could be accelerated to the same speed utilizing about $1,000 of off-board electrical energy stored in flywheels. After over two decades of development, maglev trains travel on full-scale demonstration tracks in Germany and Japan reaching speeds approaching 500 kph. Encouraging as this may appear, the energy and power required to accelerate a 1 million pound launch vehicle to 1,000 kph would radically redefine the state-of-the-art in electrical energy storage and delivery. Reaching such a goal will require levitation with sufficient stability to withstand an operating environment fundamentally different from that of a high-speed train. Recently NASA let contracts for the construction of three maglev demonstration tracks. This construction and several associated trade studies represent a first-order investigation into the feasibility of maglev launch assist. This report provides a review of these efforts, other government sponsored maglev projects and additional technical literature pertinent to maglev stability. This review brings to light details and dimensions of the maglev stability problem which are not found in previous NASA-sponsored trade studies and which must be addressed in order to realize magnetic levitation as a launch assist technology.

  18. Electrochemical oxidation behavior of hydrochlorothiazide on a glassy carbon electrode and its voltammetric determination in pharmaceutical formulations and biological fluids

    Directory of Open Access Journals (Sweden)

    Ali F. Alghamdi

    2014-09-01

    Full Text Available The electrochemical oxidation behavior of hydrochlorothiazide (HCT on a glassy carbon as a working electrode was investigated in Britton–Robinson (B–R buffer pH 3, by using anodic stripping voltammetry (ASV and cyclic voltammetry (CV. This drug gave a well-defined voltammetric oxidation peak at + 1200 mV versus an Ag/AgCl reference electrode. The electrochemical oxidation process was shown to be irreversible and diffusion controlled, with adsorption characterized over the entire pH range. The optimized conditions, such as accumulation time and potential, scan rate, frequency, pulse amplitude, varying of working electrodes, and instrumental parameters were studied. The calibration graph for HCT was obtained from 4 × 10−6 to 4 × 10−5 M (correlation coefficient = 0.997 using the developed electroanalytical method (ASV. The detection limit of this drug was 4.3 × 10−9 M. ASV and CV techniques with adequate precision and accuracy have been developed and applied for direct determination of HCT in commercial tablets without separation or extraction procedures and biological fluids such as urine and plasma.

  19. Compact cyclotron magnetic system development on the base of graphic programming

    International Nuclear Information System (INIS)

    Alenitskij, Yu.G.; Morozov, N.A.; Samsonov, E.V.

    1994-01-01

    Base on the graphic programming two programs are created: SPIRS-designed for selecting isochronous cyclotron spiral shim configuration and MEMFIC-designed for: magnetic measurement automated system control; magnetic measurement result processing; magnetic measurement file graphic scanning; graphic scanning of results of calculations of particle dynamics in the cyclotron. The programs are intended for operation with a personal computer equipped with graphic adapter board and video display providing for dotted graphics. Magnetic fields of two proton 16 and 20 MeV cyclotrons are calculated using the SPIRS program. 8 refs.; 4 figs

  20. Development of Experimental Superconducting Magnet for the Collector Ring of FAIR Project

    International Nuclear Information System (INIS)

    Zhu Yinfeng; Wu Weiyue; Wu Songtao; Liu Changle; Xu Houchang

    2010-01-01

    A pool cooled experimental magnet based on the copper stabilized NbTi superconducting wire was designed, fabricated and tested, in order to evaluate the engineering design of the dipole superconducting magnet for the collector ring (CR) of the facility for antiproton and ion research (FAIR) project. In this paper, the experimental setup including quench protection system was presented. Performance of the liquid helium pool cooled test was introduced. All of the results indicate both the performance of conductor and the experimental superconducting magnet under low temperature is stable, which suggests the engineering design are feasible for the formal magnet in CR of the FAIR project.

  1. Magnetic resonance imaging of third molars: developing a protocol suitable for forensic age estimation.

    Science.gov (United States)

    De Tobel, Jannick; Hillewig, Elke; Bogaert, Stephanie; Deblaere, Karel; Verstraete, Koenraad

    2017-03-01

    Established dental age estimation methods in sub-adults study the development of third molar root apices on radiographs. In living individuals, however, avoiding ionising radiation is expedient. Studying dental development with magnetic resonance imaging complies with this requirement, adding the advantage of imaging in three dimensions. To elaborate the development of an MRI protocol to visualise all third molars for forensic age estimation, with particular attention to the development of the root apex. Ex vivo scans of porcine jaws and in vivo scans of 10 volunteers aged 17-25 years were performed to select adequate sequences. Studied parameters were T1 vs T2 weighting, ultrashort echo time (UTE), fat suppression, in plane resolution, slice thickness, 3D imaging, signal-to-noise ratio, and acquisition time. A bilateral four-channel flexible surface coil was used. Two observers evaluated the suitability of the images. T2-weighted images were preferred to T1-weighted images. To clearly distinguish root apices in (almost) fully developed third molars an in plane resolution of 0.33 × 0.33 mm 2 was deemed necessary. Taking acquisition time limits into account, only a T2 FSE sequence with slice thickness of 2 mm generated images with sufficient resolution and contrast. UTE, thinner slice T2 FSE and T2 3D FSE sequences could not generate the desired resolution within 6.5 minutes. Three Tesla MRI of the third molars is a feasible technique for forensic age estimation, in which a T2 FSE sequence can provide the desired in plane resolution within a clinically acceptable acquisition time.

  2. Aerodynamic levitator for large-sized glassy material production.

    Science.gov (United States)

    Yoda, Shinichi; Cho, Won-Seung; Imai, Ryoji

    2015-09-01

    Containerless aerodynamic levitation processing is a unique technology for the fabrication of bulk non-crystalline materials. Using conventional aerodynamic levitation, a high reflective index (RI) material (BaTi2O5 and LaO3/2-TiO2-ZrO2 system) was developed with a RI greater than approximately 2.2, which is similar to that of diamond. However, the glass size was small, approximately 3 mm in diameter. Therefore, it is essential to produce large sized materials for future optical materials applications, such as camera lenses. In this study, a new aerodynamic levitator was designed to produce non-crystalline materials with diameters larger than 6 mm. The concept of this new levitator was to set up a reduced pressure at the top of the molten samples without generating turbulent flow. A numerical simulation was also performed to verify the concept.

  3. An octacobalt cluster based, (3,12)-connected, magnetic, porous coordination polymer.

    Science.gov (United States)

    Hou, Lei; Zhang, Wei-Xiong; Zhang, Jie-Peng; Xue, Wei; Zhang, Yue-Biao; Chen, Xiao-Ming

    2010-09-14

    Solvothermal reaction of CoSO(4) with 2,6-di-p-carboxyphenyl-4,4'-bipyridine affords a novel, octacobalt cluster based, (3,12)-connected porous framework, which exhibits gas sorption and spin-glassy magnetic behaviour.

  4. First-principles molecular dynamics study of glassy GeS2: Atomic structure and bonding properties

    Science.gov (United States)

    Celino, M.; Le Roux, S.; Ori, G.; Coasne, B.; Bouzid, A.; Boero, M.; Massobrio, C.

    2013-11-01

    The structure of glassy GeS2 is studied in the framework of density functional theory, by using a fully self-consistent first-principles molecular dynamics (FPMD) scheme. A comparative analysis is performed with previous molecular dynamics data obtained within the Harris functional (HFMD) total energy approach. The calculated total neutron structure factor exhibits an unprecedented agreement with the experimental counterpart. In particular, the height of the first sharp diffraction peak (FSDP) improves considerably upon the HFMD results. Both the Ge and the S subnetworks are affected by a consistent number of miscoordinations, coexisting with the main tetrahedral structural motif. Glassy GeS2 features a short-range order quite similar to the one found in glassy GeSe2, a notable exception being the larger number of edge-sharing connections. An electronic structure localization analysis, based on the Wannier functions formalism, provides evidence of a more enhanced ionic character in glassy GeS2 when compared to glassy GeSe2.

  5. Development of a vacuum leak test method for large-scale superconducting magnet test facilities

    International Nuclear Information System (INIS)

    Kawano, Katsumi; Hamada, Kazuya; Okuno, Kiyoshi; Kato, Takashi

    2006-01-01

    Japan Atomic Energy Agency (JAEA) has developed leak detection technology for liquid helium temperature experiments in large-scale superconducting magnet test facilities. In JAEA, a cryosorption pump that uses an absorbent cooled by liquid nitrogen with a conventional helium leak detector, is used to detect helium gas that is leaking from pressurized welded joints of pipes and valves in a vacuum chamber. The cryosorption pump plays the role of decreasing aerial components, such as water, nitrogen and oxygen, to increase the sensitivity of helium leak detection. The established detection sensitivity for helium leak testing is 10 -10 to 10 -9 Pam 3 /s. A total of 850 welded and mechanical joints inside the cryogenic test facility for the ITER Central Solenoid Model Coil (CSMC) experiments have been tested. In the test facility, 73 units of glass fiber-reinforced plastic (GFRP) insulation break are used. The amount of helium permeation through the GFRP was recorded during helium leak testing. To distinguish helium leaks from insulation-break permeation, the helium permeation characteristic of the GFRP part was measured as a function of the time of helium charging. Helium permeation was absorbed at 6 h after helium charging, and the detected permeation is around 10 -7 Pam 3 /s. Using the helium leak test method developed, CSMC experiments have been successfully completed. (author)

  6. Magnetization Transfer and Amide Proton Transfer MRI of Neonatal Brain Development.

    Science.gov (United States)

    Zheng, Yang; Wang, Xiaoming; Zhao, Xuna

    2016-01-01

    Purpose. This study aims to evaluate the process of brain development in neonates using combined amide proton transfer (APT) imaging and conventional magnetization transfer (MT) imaging. Materials and Methods. Case data were reviewed for all patients hospitalized in our institution's neonatal ward. Patients underwent APT and MT imaging (a single protocol) immediately following the routine MR examination. Single-slice APT/MT axial imaging was performed at the level of the basal ganglia. APT and MT ratio (MTR) measurements were performed in multiple brain regions of interest (ROIs). Data was statistically analyzed in order to assess for significant differences between the different regions of the brain or correlation with patient gestational age. Results. A total of 38 neonates were included in the study, with ages ranging from 27 to 41 weeks' corrected gestational age. There were statistically significant differences in both APT and MTR measurements between the frontal lobes, basal ganglia, and occipital lobes (APT: frontal lobe versus occipital lobe P = 0.031 and other groups P = 0.00; MTR: frontal lobe versus occipital lobe P = 0.034 and other groups P = 0.00). Furthermore, APT and MTR in above brain regions exhibited positive linear correlations with patient gestational age. Conclusions. APT/MT imaging can provide valuable information about the process of the neonatal brain development at the molecular level.

  7. Magnetic Resonance investigation into the mechanisms involved in the development of high-altitude cerebral edema.

    Science.gov (United States)

    Sagoo, Ravjit S; Hutchinson, Charles E; Wright, Alex; Handford, Charles; Parsons, Helen; Sherwood, Victoria; Wayte, Sarah; Nagaraja, Sanjoy; Ng'Andwe, Eddie; Wilson, Mark H; Imray, Christopher He

    2017-01-01

    Rapid ascent to high altitude commonly results in acute mountain sickness, and on occasion potentially fatal high-altitude cerebral edema. The exact pathophysiological mechanisms behind these syndromes remain to be determined. We report a study in which 12 subjects were exposed to a FiO 2  = 0.12 for 22 h and underwent serial magnetic resonance imaging sequences to enable measurement of middle cerebral artery velocity, flow and diameter, and brain parenchymal, cerebrospinal fluid and cerebral venous volumes. Ten subjects completed 22 h and most developed symptoms of acute mountain sickness (mean Lake Louise Score 5.4; p Cerebral oxygen delivery was maintained by an increase in middle cerebral artery velocity and diameter (first 6 h). There appeared to be venocompression at the level of the small, deep cerebral veins (116 cm 3 at 2 h to 97 cm 3 at 22 h; p cerebral oxygen delivery was maintained by increased arterial inflow and this preceded the development of cerebral edema. Venous outflow restriction appeared to play a contributory role in the formation of cerebral edema, a novel feature that has not been observed previously. © The Author(s) 2016.

  8. Recent developments in solution nuclear magnetic resonance (NMR)-based molecular biology.

    Science.gov (United States)

    Ziarek, Joshua J; Baptista, Diego; Wagner, Gerhard

    2018-01-01

    Visualizing post-translational modifications, conformations, and interaction surfaces of protein structures at atomic resolution underpins the development of novel therapeutics to combat disease. As computational resources expand, in silico calculations coupled with experimentally derived structures and functional assays have led to an explosion in structure-based drug design (SBDD) with several compounds in clinical trials. It is increasingly clear that "hidden" transition-state structures along activation trajectories can be harnessed to develop novel classes of allosteric inhibitors. The goal of this mini-review is to empower the clinical researcher with a general knowledge of the strengths and weaknesses of nuclear magnetic resonance (NMR) spectroscopy in molecular medicine. Although NMR can determine protein structures at atomic resolution, its unrivaled strength lies in sensing subtle changes in a nuclei's chemical environment as a result of intrinsic conformational dynamics, solution conditions, and binding interactions. These can be recorded at atomic resolution, without explicit structure determination, and then incorporated with static structures or molecular dynamics simulations to produce a complete biological picture.

  9. ANNULUS CLOSURE TECHNOLOGY DEVELOPMENT INSPECTION/SALT DEPOSIT CLEANING MAGNETIC WALL CRAWLER

    International Nuclear Information System (INIS)

    Minichan, R; Russell Eibling, R; James Elder, J; Kevin Kane, K; Daniel Krementz, D; Rodney Vandekamp, R; Nicholas Vrettos, N

    2008-01-01

    The Liquid Waste Technology Development organization is investigating technologies to support closure of radioactive waste tanks at the Savannah River Site (SRS). Tank closure includes removal of the wastes that have propagated to the tank annulus. Although amounts and types of residual waste materials in the annuli of SRS tanks vary, simple salt deposits are predominant on tanks with known leak sites. This task focused on developing and demonstrating a technology to inspect and spot clean salt deposits from the outer primary tank wall located in the annulus of an SRS Type I tank. The Robotics, Remote and Specialty Equipment (RRSE) and Materials Science and Technology (MS and T) Sections of the Savannah River National Laboratory (SRNL) collaborated to modify and equip a Force Institute magnetic wall crawler with the tools necessary to demonstrate the inspection and spot cleaning in a mock-up of a Type I tank annulus. A remote control camera arm and cleaning head were developed, fabricated and mounted on the crawler. The crawler was then tested and demonstrated on a salt simulant also developed in this task. The demonstration showed that the camera is capable of being deployed in all specified locations and provided the views needed for the planned inspection. It also showed that the salt simulant readily dissolves with water. The crawler features two different techniques for delivering water to dissolve the salt deposits. Both water spay nozzles were able to dissolve the simulated salt, one is more controllable and the other delivers a larger water volume. The cleaning head also includes a rotary brush to mechanically remove the simulated salt nodules in the event insoluble material is encountered. The rotary brush proved to be effective in removing the salt nodules, although some fine tuning may be required to achieve the best results. This report describes the design process for developing technology to add features to a commercial wall crawler and the results of

  10. Norepinephrine-modified glassy carbon electrode for the simultaneous determination of ascorbic acid and uric acid

    International Nuclear Information System (INIS)

    Zare, H.R.; Memarzadeh, F.; Ardakani, M. Mazloum; Namazian, M.; Golabi, S.M.

    2005-01-01

    The oxidation of norepinephrine (NE) on a preactivated glassy carbon electrode leads to the formation of a deposited layer of about 4.2 x 10 -10 mol cm -2 at the surface of the electrode. The electron transfer rate constant, k s , and charge transfer coefficient, α, for electron transfer between the electrode and immobilized NE film were calculated as 44 s -1 and 0.46, respectively. The NE-modified glassy carbon electrode exhibited good electrocatalytic properties towards ascorbic acid (AA) oxidation in phosphate buffer (pH 7.0) with an overpotential of about 475 mV lower than that of the bare electrode. The electrocatalytic response was evaluated by cyclic voltammetry, chronoamperometry, amperometry and rotating disk voltammetry. The overall number of electrons involved in the catalytic oxidation of AA and the number of electrons involved in the rate-determining step are 2 and 1, respectively. The rate constant for the catalytic oxidation of AA was evaluated by RDE voltammetry and an average value of k h was found to be 8.42 x 10 3 M -1 s -1 . Amperometric determination of AA in stirred solution exhibits a linear range of 2.0-1300.0 μM (correlation coefficient 0.9999) and a detection limit of 0.076 μM. The precision of amperometry was found to be 1.9% for replicate determination of a 49.0 μM solution of AA (n = 6). In differential pulse voltammetric measurements, the NE-modified glassy carbon electrode can separate the AA and uric acid (UA) signals. Ascorbic acid oxidizes at more negative potential than UA. Also, the simultaneous determination of UA and AA is achieved at the NE-modified electrode

  11. The electrocatalytical reduction of m-nitrophenol on palladium nanoparticles modified glassy carbon electrodes

    International Nuclear Information System (INIS)

    Shi Qiaofang; Diao Guowang

    2011-01-01

    Highlights: ► The deposition of palladium on a GC electrode was performed by cyclic voltammetry. ► SEM images showed palladium nanoparticles deposited on a glassy carbon (GC) electrode. ► The Pd/GC electrode can effectively catalyze m-nitrophenol in aqueous media. ► The reduction of m-nitrophenol on the Pd/GC electrode depended on potential and pH. ► XPS spectra of the Pd/GC electrodes demonstrated the presence of palladium. - Abstract: Palladium nanoparticles modified glassy carbon electrodes (Pd/GC) were prepared via the electrodeposition of palladium on a glassy carbon (GC) electrode using cyclic voltammetry in different sweeping potential ranges. The scanning electron microscope images of palladium particles on the GC electrodes indicate that palladium particles with diameters of 20–50 nm were homogeneously dispersed on the GC electrode at the optimal deposition conditions, which can effectively catalyze the reduction of m-nitrophenol in aqueous solutions, but their catalytic activities are strongly related to the deposition conditions of Pd. The X-ray photoelectron spectroscopy spectra of the Pd/GC electrode confirmed that 37.1% Pd was contained in the surface composition of the Pd/GC electrode. The cyclic voltammograms of the Pd/GC electrode in the solution of m-nitrophenol show that the reduction peak of m-nitrophenol shifts towards the more positive potentials, accompanied with an increase in the peak current compared to the bare GC electrode. The electrocatalytic activity of the Pd/GC electrode is affected by pH values of the solution. In addition, the electrolysis of m-nitrophenol under a constant potential indicates that the reduction current of m-nitrophenol on the Pd/GC electrode is approximately 20 times larger than that on the bare GC electrode.

  12. Development of a metallic magnetic calorimeter for high resolution spectroscopy; Entwicklung eines metallischen magnetischen Kalorimeters fuer die hochaufloesende Roentgenspektroskopie

    Energy Technology Data Exchange (ETDEWEB)

    Linck, M.

    2007-05-02

    In this thesis the development of a metallic magnetic calorimeter for high resolution detection of single x-ray quanta is described. The detector consists of an X-ray absorber and a paramagnetic temperature sensor. The raise in temperature of the paramagnetic sensor due to the absorption of a single X-ray is measured by the change in magnetization of the sensor using a low-noise SQUID magnetometer. The thermodynamic properties of the detector can be described by a theoretical model based on a mean field approximation. This allows for an optimization of the detector design with respect to signal size. The maximal archivable energy resolution is limited by thermodynamic energy fluctuations between absorber, heat bath and thermometer. An interesting field of application for a metallic magnetic calorimeter is X-ray astronomy and the investigation of X-ray emitting objects. Through high-resolution X-ray spectroscopy it is possible to obtain information about physical processes of even far distant objects. The magnetic calorimeter that was developed in this thesis has a metallic absorber with a quantum efficiency of 98% at 6 keV. The energy resolution of the magnetic calorimeter is EFWHM=2.7 eV at 5.9 keV. The deviation of the detector response from a linear behavior of the detector is only 0.8% at 5.9 keV. (orig.)

  13. Electroanalysis of thiocyanate using a novel glassy carbon electrode modified by aryl radicals and cobalt tetracarboxyphthalocyanine

    Energy Technology Data Exchange (ETDEWEB)

    Matemadombo, Fungisai; Nyokong, Tebello [Rhodes University, Grahamstown (South Africa). Department of Chemistry; Westbroek, Philippe [Ghent University, Ghent (Belgium). Department of Textiles

    2007-12-01

    Electrochemical grafting of 4-nitrobenzenediazonium tetrafluoroborate onto a glassy carbon electrode (GCE) results in the formation of a nitrophenyl radical, which reacts with the surface to form a covalent bond (grafting) and results in a nitrophenyl modified electrode. The nitro group is electrochemically reduced to a NH{sub 2} group. Cobalt tetracarboxyphthalocyanine (CoTCPc) complex is then attached to the NH{sub 2} group using 1-ethyl-3-(3-dimethylaminopropyl)-carbodiimide (EDC) and N-hydroxysuccinimide (NHS) as coupling agents. The new CoTCPc modified electrode was characterized using cyclic voltammetry and then employed for the catalytic oxidation of thiocyanate. (author)

  14. DEVELOPMENT OF EXTREMELY LOW FREQUENCY PASSIVE SHIELDING APPLICATION USING MAGNETIC AQUEOUS SUBSTRATE

    Directory of Open Access Journals (Sweden)

    NOOR ASHIKIN MOHD RASHID

    2016-04-01

    Full Text Available Public concerns on Extremely Low Frequency (ELF Electromagnetic Field (EMF exposure have been elongated since the last few decades. Electrical substations and high tension rooms in commercial buildings were among the contributing factors emanating ELF magnetic fields. This paper discussed various shielding methods conventionally used in mitigating the ELF exposure. Nevertheless, the standard methods were found to be impractical and incapable of meeting currents shielding demands. In response to that, remarkable researches were conducted in effort to invent novel methods which is more convenient and efficient such as magnetic aqueous shielding or paint, textiles and papers shielding. A magnetic aqueous substrate, Manganese Zinc Ferrite was used as shielding material. The magnetic field and flux distribution inside the aqueous magnetic material are evaluated to optimize shielding against ELFEMF exposure, as to mitigate its exposure.

  15. Development of a magnetic coagulant based on Moringa oleifera seed extract for water treatment.

    Science.gov (United States)

    Santos, Tássia R T; Silva, Marcela F; Nishi, Leticia; Vieira, Angélica M S; Fagundes-Klen, Márcia R; Andrade, Murilo B; Vieira, Marcelo F; Bergamasco, Rosângela

    2016-04-01

    In this work, to evaluate the effectiveness of the coagulation/flocculation using a natural coagulant, using Moringa oleifera Lam functionalized with magnetic iron oxide nanoparticles, producing flakes that are attracted by an external magnetic field, thereby allowing a fast settling and separation of the clarified liquid, is proposed. The removal efficiency of the parameters, apparent color, turbidity, and compounds with UV254nm absorption, was evaluated. The magnetic functionalized M. oleifera Lam coagulant could effectively remove 90 % of turbidity, 85 % of apparent color, and 50 % for the compounds with absorption at UV254nm, in surface waters under the influence of an external magnetic field within 30 min. It was found that the coagulation/flocculation treatment using magnetic functionalized M. oleifera Lam coagulant was able to reduce the values of the physico-chemical parameters evaluated with reduced settling time.

  16. Magnetic Moments in the Past: developing archaeomagnetic dating in the UK

    Science.gov (United States)

    Outram, Zoe; Batt, Catherine M.; Linford, Paul

    2010-05-01

    Magnetic studies of archaeological materials have a long history of development in the UK and the data produced by these studies is a key component of global models of the geomagnetic field. However, archaeomagnetic dating is not a widely used dating technique in UK archaeology, despite the potential to produce archaeologically significant information that directly relates to human activity. This often means that opportunities to improve our understanding of the past geomagnetic field are lost, because archaeologists are unaware of the potential of the method. This presentation discusses a project by the University of Bradford, UK and English Heritage to demonstrate and communicate the potential of archaeomagnetic dating of archaeological materials for routine use within the UK. The aims of the project were achieved through the production of a website and a database for all current and past archaeomagnetic studies carried out in the UK. The website provides archaeologists with the information required to consider the use of archaeomagnetic dating; including a general introduction to the technique, the features that can be sampled, the precision that can be expected from the dates and how much it costs. In addition, all archaeomagnetic studies carried out in the UK have been collated into a database, allowing similar studies to be identified on the basis of the location of the sites, the archaeological period and type of feature sampled. This clearly demonstrates how effective archaeomagnetic dating has been in different archaeological situations. The locations of the sites have been mapped using Google Earth so that studies carried out in a particular region, or from a specific time period can be easily identified. The database supports the continued development of archaeomagnetic dating in the UK, as the data required to construct the secular variation curves can be extracted easily. This allows the curves to be regularly updated following the production of new

  17. Serrated magnetic properties in metallic glass by thermal cycle

    International Nuclear Information System (INIS)

    Ri Myong-Chol; Sohrabi, Sajad; Ding Da-Wei; Wang Wei-Hua; Dong Bang-Shao; Zhou Shao-Xiong

    2017-01-01

    Fe-based metallic glasses (MGs) with excellent soft magnetic properties are applicable in a wide range of electronic industry. We show that the cryogenic thermal cycle has a sensitive effect on soft magnetic properties of Fe 78 Si 9 B 13 glassy ribbon. The values of magnetic induction (or magnetic flux density) B and coercivity H c show fluctuation with increasing number of thermal cycles. This phenomenon is explained as thermal-cycle-induced stochastically structural aging or rejuvenation which randomly fluctuates magnetic anisotropy and, consequently, the magnetic induction and coercivity. Overall, increasing the number of thermal cycles improves the soft magnetic properties of the ribbon. The results could help understand the relationship between relaxation and magnetic property, and the thermal cycle could provide an effective approach to improving performances of metallic glasses in industry. (paper)

  18. A study of the electro-catalytic oxidation of methanol on a cobalt hydroxide modified glassy carbon electrode

    International Nuclear Information System (INIS)

    Jafarian, M.; Mahjani, M.G.; Heli, H.; Gobal, F.; Khajehsharifi, H.; Hamedi, M.H.

    2003-01-01

    Cobalt hydroxide modified glassy carbon electrodes (CHM/GC) prepared by the anodic deposition in presence of tartrate ions have been used for the electro-catalytic oxidation of methanol in alkaline solutions where the methods of cyclic voltammetery (CV), chronoamperometry (CA) and impedance spectroscopy (IS) have been employed. In CV studies, in the presence of methanol the peak current of the oxidation of cobalt hydroxide increase is followed by a decrease in the corresponding cathodic current. This suggests that the oxidation of methanol is being catalysed through the mediated electron transfer across the cobalt hydroxide layer comprising of cobalt ions of various valence states. A mechanism based on the electro-chemical generation of Co(IV) active sites and their subsequent consumptions by methanol have been discussed and the corresponding rate law under the control of charge transfer has been developed and kinetic parameters have been derived. In this context the charge transfer resistance accessible both theoretically and through the IS studies have been used as a criteria. Under the CA regimes the reaction followed a Cottrellian behaviour

  19. Culture independent survey of the microbiota of the glassy-winged sharpshooter (Homalodisca vitripennis) using 454 pyrosequencing.

    Science.gov (United States)

    Hail, Daymon; Lauzìere, Isabelle; Dowd, Scot E; Bextine, Blake

    2011-02-01

    The glassy-winged sharpshooter, Homalodisca vitripennis (Germar), is an invasive pest that has spread across the southern and western United States. H. vitripennis is highly polyphagous and voracious, feeding on at least 100 plant species and consuming up to 100 times its weight in xylem fluid daily. The insect is a vector of the phytopathogen Xylella fastidiosa (Wells), which is the causative agent of Pierce's disease in grapevines. To evaluate the microbial flora associated with H. vitripennis, total DNA extracts from hemolymph, alimentary canal excretions, and whole insect bodies were subjected to 16S rDNA pyrosequencing using the bTEFAP methodology and the resulting sequences (370-520 bp in length) were compared with a curated high quality 16S database derived from GenBank http://www.ncbi.nlm.nih.gov. Species from the genera Wolbachia, Delftia (formerly Pseudomonas), Pectobacterium, Moraxella, Serratia, Bacillus, and many others were detected and a comprehensive picture of the microbiome associated with H. vitripennis was established. Some of the bacteria identified in this report are initial discoveries; providing a breadth of knowledge to the microbial flora of this insect pest can serve as a reservoir of information for developing biological control strategies. © 2011 Entomological Society of America

  20. Electrooxidation of sulfanilamide and its voltammetric determination in pharmaceutical formulation, human urine and serum on glassy carbon electrode

    Directory of Open Access Journals (Sweden)

    Bruno R.L. Ferraz

    2018-02-01

    Full Text Available For the first time, sulfanilamide (SFD was determined in otologic solution, human urine and serum by electroanalytical techniques on glassy carbon electrode (GCE. The cyclic voltammetry (CV experiments showed an irreversible oxidation peak at +1.06 V in 0.1 mol/L BRBS (pH = 2.0 at 50 mV/s. Different voltammetric scan rates (from 10 to 250 mV/s suggested that the oxidation of SFD on the GCE was a diffusion-controlled process. Square-wave voltammetry (SWV method under optimized conditions showed a linear response to SFD from 5.0 to 74.7 μmol/L (R = 0.999 with detection and quantification limits of 0.92 and 3.10 μmol/L, respectively. The developed SWV method showed better results for detection limit and linear range than the chronoamperometry method. It has been successfully applied to determine SFD concentration in pharmaceutical formulation, human urine and serum samples with recovery close to 100%.