WorldWideScience

Sample records for determining lead sources

  1. Lead pollution sources and Impacts

    International Nuclear Information System (INIS)

    El-Haggar, S.M.; Saad, S.G.; Saleh, S.K.; El-Kady, M.A.

    1996-01-01

    Despite the medical awareness of lead toxicity, and despite legislation designed to reduce environmental contamination, lead is one of the most widely used heavy metals. Significant human exposure occurs from automobile exhaust fumes, cigarette smoking, lead-based paints and plumbing systems lead spread in the environment can take place in several ways, the most important of which is through the lead compounds released in automobile exhaust as a direct result of the addition of tetraethyl or tetraethyl lead to gasoline as octane boosting agents. Of special is the effect of lead pollution on children, which affects their behavioral and educational attributes considerably. The major channel through through which lead is absorbed is through inhalation of lead compounds in the atmosphere. Lead is a heavy metal characterized its malleability, ductility and poor conduction of electricity. So, it has a wide range of applications ranging from battery manufacturing to glazing ceramics. It is rarely found free in nature but is present in several minerals and compounds. The aim of this paper is to discuss natural and anthropogenic sources of lead together with its distribution and trends with emphasis on egypt. The effects of lead pollution on human health, vegetation and welfare are also presented. It could be concluded that, the excessive release of lead into the environment, especially through the atmosphere, can produce many detrimental and sometimes fatal effects on human, agriculture and zoological life. Besides, it is very plain that there is a serious problem of pollution lead in egypt and specially in cairo. 7 figs

  2. Investigation of spectral interferences in the determination of lead in fertilizers and limestone samples using high-resolution continuum source graphite furnace atomic absorption spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Borges, Aline R. [Instituto de Química, Universidade Federal do Rio Grande do Sul, Av. Bento Gonçalves 9500, 91501-970 Porto Alegre, RS (Brazil); Instituto Nacional de Ciência e Tecnologia do CNPq — INCT de Energia e Ambiente, Universidade Federal da Bahia, Salvador, BA (Brazil); Becker, Emilene M.; François, Luciane L.; Jesus, Alexandre de [Instituto de Química, Universidade Federal do Rio Grande do Sul, Av. Bento Gonçalves 9500, 91501-970 Porto Alegre, RS (Brazil); Vale, Maria Goreti R. [Instituto de Química, Universidade Federal do Rio Grande do Sul, Av. Bento Gonçalves 9500, 91501-970 Porto Alegre, RS (Brazil); Instituto Nacional de Ciência e Tecnologia do CNPq — INCT de Energia e Ambiente, Universidade Federal da Bahia, Salvador, BA (Brazil); Welz, Bernhard [Instituto Nacional de Ciência e Tecnologia do CNPq — INCT de Energia e Ambiente, Universidade Federal da Bahia, Salvador, BA (Brazil); Departamento de Química, Universidade Federal de Santa Catarina, 88040-900 Florianópolis, SC (Brazil); Dessuy, Morgana B., E-mail: mbdessuy@ufrgs.br [Instituto de Química, Universidade Federal do Rio Grande do Sul, Av. Bento Gonçalves 9500, 91501-970 Porto Alegre, RS (Brazil); Andrade, Jailson B. de [Instituto Nacional de Ciência e Tecnologia do CNPq — INCT de Energia e Ambiente, Universidade Federal da Bahia, Salvador, BA (Brazil)

    2014-11-01

    In the present work, spectral interferences on the determination of lead in fertilizer and limestone samples were investigated using high-resolution continuum source graphite furnace atomic absorption spectrometry at the main analytical lines: 217.001 and 283.306 nm. For these investigations, samples were introduced into the furnace as slurry together with a mixture of Pd and Mg as chemical modifier. Spectral interferences were observed for some samples at both analytical lines. In order to verify whether a wet digestion procedure would avoid these interferences, a reference method for wet digestion of fertilizers was employed as an alternative sample preparation procedure. However, the same interferences were also observed in the digested samples. In order to identify and eliminate the fine-structured background using a least-squares background correction, reference spectra were generated using the combination of different species. The use of the latter technique allowed the elimination of spectral interferences for most of the investigated samples, making possible the determination of lead in fertilizer and limestone samples free of interferences. The best results were found using a reference spectrum of NH{sub 4}H{sub 2}PO{sub 4} at 217.001 nm, and a mixture of H{sub 2}SO{sub 4} + Ca and HNO{sub 3} + Ca at the 283.306 nm line. The accuracy of the method was evaluated using a certified reference material “Trace Elements in Multi-Nutrient Fertilizer”. Similar results were obtained using line source graphite furnace atomic absorption spectrometry with Zeeman-effect background correction, indicating that the latter technique was also capable to correct the spectral interferences, at least in part. - Highlights: • Spectral interferences on the determination of lead in fertilizers and limestone. • The analytical lines at 217.001 nm and 283.306 nm using HR-CS GF AAS. • Various combinations of compounds were used to create reference spectra. • LSBC

  3. Determination of Pb (Lead, Cd (Cadmium, Cr (Chromium, Cu (Copper, and Ni (Nickel in Chinese tea with high-resolution continuum source graphite furnace atomic absorption spectrometry

    Directory of Open Access Journals (Sweden)

    Wen-Si Zhong

    2016-01-01

    Full Text Available The contents of lead, cadmium, chromium, copper, and nickel were determined in 25 tea samples from China, including green, yellow, white, oolong, black, Pu'er, and jasmine tea products, using high-resolution continuum source graphite furnace atomic absorption spectrometry. The methods used for sample preparation, digestion, and quantificational analysis were established, generating satisfactory analytical precisions (represented by relative standard deviations ranging from 0.6% to 2.5% and recoveries (98.91–101.32%. The lead contents in tea leaves were 0.48–10.57 mg/kg, and 80% of these values were below the maximum values stated by the guidelines in China. The contents of cadmium and chromium ranged from 0.01 mg/kg to 0.39 mg/kg and from 0.27 mg/kg to 2.45 mg/kg, respectively, remaining in compliance with the limits stipulated by China's Ministry of Agriculture. The copper contents were 7.73–63.71 mg/kg; only 64% of these values complied with the standards stipulated by the Ministry of Agriculture. The nickel contents ranged from 2.70 mg/kg to 13.41 mg/kg. Consequently, more attention must be paid to the risks of heavy metal contamination in tea. The quantitative method established in this work lays a foundation for preventing heavy metal toxicity in human from drinking tea and will help establish regulations to control the contents of heavy metals in tea.

  4. Lead sources in human diet in Greenland

    DEFF Research Database (Denmark)

    Bjerregaard, Peter; Johansen, Poul; Mulvad, Gert

    2004-01-01

    Although blood lead levels have declined in Greenland, they are still elevated despite the fact that lead levels in the Greenland environment are very low. Fragments of lead shot in game birds have been suggested as an important source of dietary exposure, and meals of sea birds, particularly eider......, contain high concentrations of lead. In a cross-sectional population survey in Greenland in 1993-1994, blood lead adjusted for age and sex was found to be associated with the reported consumption of sea birds. Participants reporting less than weekly intake of sea birds had blood lead concentrations...... of approximately 75 microg/L, whereas those who reported eating sea birds several times a week had concentrations of approximately 110 microg/L, and those who reported daily intake had concentrations of 170 microg/L (p = 0.01). Blood lead was not associated with dietary exposure to other local or imported food...

  5. Determined Initial lead for South Of Isua (SOI) terrain suggests a single homogeneous source for it and possibly other archaean rocks

    Science.gov (United States)

    Tera, F.

    2011-12-01

    A Thorogenic-Uranogenic Lead Isotope Plane (TULIP), which entails plotting 206/208 (or its reverse) vs 207/208 (or its reverse), was applied to the Pb data on South of Isua (SOI) by Kamber et al., (1). When the data on 20 samples of these rocks and feldspars are plotted in pairs (each pair is a rock and its feldspar) on TULIP, they fall on 10 mixing lines that converge on a single spot (Fig. 1). This is the end member initial lead (EMIL). The 206/208 & 207/208 so determined are 0.3675 and 0.43525, respectively. From these values one calculates 207/206 = 1.1843 ± 0.0007, for EMIL. This pattern requires either: A) each pair has a singular kappa, K = 232Th/238U, different from others, or B) a pair's in situ decay Pb was homogenized in recent times. On 204/206 vs 207/206 diagram, the whole rocks of SOI define a 3.776 Ga isochron (2). From this and EMIL's 207/206, one obtains: 206/204 = 10.977, 207/204 = 12.974; and 208/204 = 29.756. This singularity of initial Pb contrasts with a deduced variability by the original authors (1). EMIL's radiogenic *(207/206) = 1.6220, gives a single-stage age = 5.9 Ga, indicating inapplicability of its evolution in one stage. Also, the μ calculated from 238U-206Pb for the single stage is different from that inferred from 235U-207Pb, confirming disqualification of this scenario. Reconciliation of the two decay schemes necessitates assumption of EMIL evolution in a minimum of two stages. Starting at 4.563 Ga, five scenarios were assumed: First stage ends and second starts at 4.55, 4.54, 4.53, 4.52 or 4.51 Ga. Second stages end at 3.776 Ga. The calculated μ1 for the first stage are 106, 59.5, 44.6, 36.3 and 30.9 respectively. For μ2 the change is limited, from 5.45 to 5.28. Only an average calculated K for both stages is possible. For the five outlined scenarios it ranges from 1.118 to 1.111. Earlier, Tera (3) observed that initial Pb of the oldest terrestrial reservoir requires evolution in two stages. There too μ1 >> μ2. Data on

  6. The identification of lead ammunition as a source of lead exposure in First Nations: The use of lead isotope ratios

    International Nuclear Information System (INIS)

    Tsuji, Leonard J.S.; Wainman, Bruce C.; Martin, Ian D.; Sutherland, Celine; Weber, Jean-Philippe; Dumas, Pierre; Nieboer, Evert

    2008-01-01

    The use of lead shotshell to hunt water birds has been associated with lead-contamination in game meat. However, evidence illustrating that lead shotshell is a source of lead exposure in subsistence hunting groups cannot be deemed definitive. This study seeks to determine whether lead shotshell constitutes a source of lead exposure using lead isotope ratios. We examined stable lead isotope ratios for lichens, lead shotshell and bullets, and blood from residents of Fort Albany and Kashechewan First Nations, and the City of Hamilton, Ontario, Canada. Data were analyzed using ANOVA and regression analyses. ANOVA of isotope ratios for blood revealed significant differences with respect to location, but not sex. Hamilton differed from both Kashechewan and Fort Albany; however, the First Nations did not differ from each other. ANOVA of the isotope ratios for lead ammunition and lichens revealed no significant differences between lichen groups (north and south) and for the lead ammunition sources (pellets and bullets). A plot of 206 Pb/ 204 Pb and 206 Pb/ 207 Pb values illustrated that lichens and lead ammunition were distinct groupings and only the 95% confidence ellipse of the First Nations group overlapped that of lead ammunition. In addition, partial correlations between blood-lead levels (adjusted for age) and isotope ratios revealed significant (p 206 Pb/ 204 Pb and 206 Pb/ 207 Pb, and a significant negative correlation for 208 Pb/ 206 Pb, as predicted if leaded ammunition were the source of lead exposure. In conclusion, lead ammunition was identified as a source of lead exposure for First Nations people; however, the isotope ratios for lead shotshell pellets and bullets were indistinguishable. Thus, lead-contaminated meat from game harvested with lead bullets may also be contributing to the lead body burden

  7. Use of Pb and Sr isotopes on the determination of lead mineralization sources from Ribeira valley - Sao Paulo and Parana states

    International Nuclear Information System (INIS)

    Tassinari, C.C.G.; Barbour, A.P.; Sato, K.; Daitx, E.C.

    1990-01-01

    A lead and strontium isotope study was carried out on galena, barite and calcite from Pb-Ag syngenetic stratiform (Perau type) and hydrothermal veins (Panela type) deposits from Vale do Ribeira region (Sao Paulo and Parana states). The leads from the Perau and Panelas type deposits have respectively isotope ratios (sup(206)Pb/ sup(204)Pb 16.157 to 16.505 amd 16.520 to 17.273; sup(207)Pb/ sup(204)Pb = 15.466 to 15.720 and 15.470 to 15.780 and sup(208)Pb/ sup(204)Pb = 36.370 to 36.763 and 37.043 to 38.243), that defined a Stacey and Kramers model ages mainly concentrate within 1.7-1.5Ga. A review of published Pb isotopic compositions for these deposits and considerations of new Sr isotope data and Pb results using plumbotectonics model, indicate that the Perau type mineralizations are related to the syngenetic process and the Pb are derived from upper crust with a short crustal residence time. For the Panelas type deposits the Pb and Sr isotope studies support the conclusion that the ores were emplaced during regional metamorphism and the Pb were derived from lithologically complex source which may include metasedimentary and basement rocks. (author)

  8. Determining tissue-lead levels in large game mammals harvested with lead bullets: human health concerns.

    Science.gov (United States)

    Tsuji, L J S; Wainman, B C; Jayasinghe, R K; VanSpronsen, E P; Liberda, E N

    2009-04-01

    Recently, the use of lead isotope ratios has definitively identified lead ammunition as a source of lead exposure for First Nations people, but the isotope ratios for lead pellets and bullets were indistinguishable. Thus, lead-contaminated meat from game harvested with lead bullets may also be contributing to the lead body burden; however, few studies have determined if lead bullet fragments are present in big game carcasses. We found elevated tissue-lead concentrations (up to 5,726.0 microg/g ww) in liver (5/9) and muscle (6/7) samples of big game harvested with lead bullets and radiographic evidence of lead fragments. Thus, we would advise that the tissue surrounding the wound channel be removed and discarded, as this tissue may be contaminated by lead bullet fragments.

  9. Spectrochemical determination of lead in wines

    Directory of Open Access Journals (Sweden)

    DRAGAN MARKOVIC

    2000-06-01

    Full Text Available The determination of lead in wines of different origin was performed by means of atomic emission spectroscopy with argon stabilized DC. U-shaped arc and electrothermal atomic absorption spectrometry. The comparison of the results obtained by the direct and standard addition method has indicated the presence of a depressive effect of the complex organic matrix. The effect is avoided successfully by mineralization, as well as by dissolution of the samples. Thus, a relative simple but precise and sensitive method involving the application of a stabilized arc and photoelectric detection with time integration of the emission signals is recommended for the determination of low concentrations of lead in wines. The complex organic matrix was investigated by recording the IR spectra of different wine fractions.

  10. Lead isotopes as an environmental indicator of pollution sources

    International Nuclear Information System (INIS)

    Aaberg, G.; Pacyna, J.; Stray, H.

    1997-02-01

    An interesting question when determining and quantifying pollution is the characterisation of the sources. Also, is the pollution locally derived or is it longtransported? Analyses of Pb isotope ratios and Pb concentrations on airfilter from Oslo, Norway, together with analyses of coal of different origin and wood, show that the decrease in total Pb in the first half of the 1990's is not due only to the reduction of leaded petrol but that there are other important sources for the pollution which have been cut down. The reduction in emissions from coal burning in Europe can be seen on airfilter from Oslo and also the following reduction in leaded petrol. An isotopic study of lead on airfilter from the countryside outside Oslo implies that the finer particles have been atmospherically long transported while the coarser particles are of a more local origin, e.g. from domestic burning of wood. The above results show that the use of a natural isotopic system like Pb is a powerful tool for e.g. the determination of pollution, routes of its transportation, for the monitoring of processes of the present, and for provenance determinations. 7 refs., 8 figs., 2 tabs

  11. Identification of sources of lead exposure in French children by lead isotope analysis: a cross-sectional study

    Directory of Open Access Journals (Sweden)

    Lucas Jean-Paul

    2011-08-01

    Full Text Available Abstract Background The amount of lead in the environment has decreased significantly in recent years, and so did exposure. However, there is no known safe exposure level and, therefore, the exposure of children to lead, although low, remains a major public health issue. With the lower levels of exposure, it is becoming more difficult to identify lead sources and new approaches may be required for preventive action. This study assessed the usefulness of lead isotope ratios for identifying sources of lead using data from a nationwide sample of French children aged from six months to six years with blood lead levels ≥25 μg/L. Methods Blood samples were taken from 125 children, representing about 600,000 French children; environmental samples were taken from their homes and personal information was collected. Lead isotope ratios were determined using quadrupole ICP-MS (inductively coupled plasma - mass spectrometry and the isotopic signatures of potential sources of exposure were matched with those of blood in order to identify the most likely sources. Results In addition to the interpretation of lead concentrations, lead isotope ratios were potentially of use for 57% of children aged from six months to six years with blood lead level ≥ 25 μg/L (7% of overall children in France, about 332,000 children, with at least one potential source of lead and sufficiently well discriminated lead isotope ratios. Lead isotope ratios revealed a single suspected source of exposure for 32% of the subjects and were able to eliminate at least one unlikely source of exposure for 30% of the children. Conclusions In France, lead isotope ratios could provide valuable additional information in about a third of routine environmental investigations.

  12. Isotope ratios of lead as pollutant source indicators

    International Nuclear Information System (INIS)

    Chow, T.J.; Snyder, C.B.; Earal, J.L.

    1975-01-01

    Each lead ore deposit has its characteristic isotope ratios which are fixed during mineral ore genesis, and this unique property can be used to indicate the source of lead pollutants in the environment. The wolld production of primary lead is tabulated, and the geochemical significances of lead isotope ratios are discussed. The manufacture of lead alkyl additives for gasoline, which is the major source of lead pollutants, utilizes about 10% of the world annual consumption of lead. The isotope ratios of lead in gasoline, aerosols, soils and plants are correlated. Lead additives in various brands of gasoline sold in one region do not have the same isotope ratios. Regional variations in isotope ratios of lead additives were observed. This reflects the fact that petroleum refineries obtained the additives from various lead alkyl manufacturers which utilized lead from different mining districts. A definite changing trend of isotope ratios of lead pollutants in the San Diego, California (USA), area was detected. The lead shows a gradual increase in its radiogenic components during the past decade. This trend can be explained by the change of lead sources used by the additive manufacturers: Lead isotope ratios of the mid-1960's gasoline additives in the United States of America reflected those of less radiogenic leads imported from Canada, Australia, Peru and Mexico. Since then, the U.S. lead production has doubled-mainly from the Missouri district of highly radiogenic lead. Meanwhile, there has been a decrease in total lead imports. These combined effects result in changes in isotope ratios, from the less to more radiogenic, of the pooled lead. (aothor)

  13. Determination of lead 210 atmospheric fluxes in Syria

    International Nuclear Information System (INIS)

    Al-Masri, M. S.; Shaik Khalil, H.

    2001-01-01

    Lead 210 atmospheric fluxes were determined by collecting 51 profiles from Syrian soil during 1998. Lead 210 fluxes in Syria calculated from lead 210 inventory in soil ranged from 15 Bq.m -2 .y -1 and 407 Bq.m -2 .y -1 with an average value of 128 Bq.m -2 .y -1 . the highest fluxes were found to be in Hama area due to the Gaab fault, which is considered as a radon source in the area. In addition, fluxes were also high in most sites, which are located in Syria valleys and around the lakes. Moreover, the study has indicated that there is no linear relation between lead 210 flux values and other parameters such as annual rainfall and bulk density of the soil. On the other hand, an effect, of those two factors on lead 210 distribution with depth has been observed. In addition, the results of variable lead 210 fluxes from site to another have proved that it is necessary, in order to obtain a representative mean value of lead 210 flux obtained in this study is within the worldwide range for lead 210 flux. (Author)

  14. Determining lead sources in Mexico using the lead isotope ratio La identificación de fuentes de exposición a plomo en México a través de la determinación de la razón de isótopos de plomo

    Directory of Open Access Journals (Sweden)

    Madhu Chaudhary-Webb

    2003-01-01

    Full Text Available OBJECTIVE: Lead poisoning can, in some cases, be traced to a specific route or source of exposure on the basis of the individual's blood lead isotope ratio. To assess the major source of lead exposure among women residing in Mexico City, we compared blood, ceramic, and gasoline lead isotope ratios. MATERIAL AND METHODS: The study population, randomly selected from participants of a large trial, (1/1996-12/1996 comprised of 16 women whose lead levels exceeded 10 µg/dl and who reported using lead-glazed ceramics. Lead isotope ratios were performed on a Perkin Elmer 5000 Inductively Coupled Plasma Mass Spectrometer (ICP-MS interfaced with a Perkin Elmer HGA-600MS Electrothermal Vaporization System (ETV. RESULTS: The isotope ratios (206Pb/204Pb, 207Pb/204Pb, and 208Pb/204Pb of both the blood specimens and their corresponding ceramic specimens were highly correlated, with r=0.9979, r²=0.9958, r=0.9957, r²=0.9915 and r=0.9945, r²=0.9890 values for the three isotope ratios, respectively, suggesting that the lead exposure most likely resulted from the use of these ceramic. Measurements of lead isotope ratios from leaded gasoline in use at the time of blood sampling, differed from those in blood and ceramics. CONCLUSIONS: Determining lead isotope ratios can be an efficient tool to identify a major source of lead exposure and to support the implementation of public health prevention and control measures.OBJETIVO: Identificar la fuente principal de exposición a plomo entre mujeres residentes en la Ciudad de México, por medio de la comparación de las razones de isótopos de plomo en sangre, cerámica y gasolina. MATERIAL Y MÉTODOS: La población de estudio fue seleccionada aleatoriamente de participantes de una muestra obtenida de enero a diciembre de 1996 y consistió en 16 mujeres con niveles de plomo mayores a 10 µg/dl, que usaban cerámica vidriada con plomo. Las razones de isótopos de plomo se obtuvieron con un espectrómetro de masa de

  15. Lead shot from hunting as a source of lead in human blood

    International Nuclear Information System (INIS)

    Johansen, Poul; Pedersen, Henning Sloth; Asmund, Gert; Riget, Frank

    2006-01-01

    This study investigates the relationship between the intake of birds hunted with lead shot and the lead concentration in human blood. Fifty adult men from Nuuk, Greenland took part in the study. From September 2003 to June 2004 they regularly gave blood samples and recorded how many birds they ate. We found a clear relationship between the number of bird meals and blood lead and also a clear seasonal variation. The concentration was highest in mid-winter when bird consumption is at its highest. Blood lead was low (15 μg/L, mean concentration) among the participants reporting not eating birds. Among those reporting to eat birds regularly, blood lead was significantly higher, up to 128 μg/L (mean concentration). Concentrations depended on the frequency of bird meals: the more the bird meals, the higher the resulting blood lead. This clear relationship points to lead shot as the dominating lead source to people in Greenland. - Birds hunted with lead shot and consumed are a source of lead in human blood

  16. Lead shot from hunting as a source of lead in human blood

    Energy Technology Data Exchange (ETDEWEB)

    Johansen, Poul [National Environmental Research Institute, Frederiksborgvej 399, DK-4000 Roskilde (Denmark)]. E-mail: poj@dmu.dk; Pedersen, Henning Sloth [Primary Health Care Center, DK-3900 Nuuk (Greenland); Asmund, Gert [National Environmental Research Institute, Frederiksborgvej 399, DK-4000 Roskilde (Denmark); Riget, Frank [National Environmental Research Institute, Frederiksborgvej 399, DK-4000 Roskilde (Denmark)

    2006-07-15

    This study investigates the relationship between the intake of birds hunted with lead shot and the lead concentration in human blood. Fifty adult men from Nuuk, Greenland took part in the study. From September 2003 to June 2004 they regularly gave blood samples and recorded how many birds they ate. We found a clear relationship between the number of bird meals and blood lead and also a clear seasonal variation. The concentration was highest in mid-winter when bird consumption is at its highest. Blood lead was low (15 {mu}g/L, mean concentration) among the participants reporting not eating birds. Among those reporting to eat birds regularly, blood lead was significantly higher, up to 128 {mu}g/L (mean concentration). Concentrations depended on the frequency of bird meals: the more the bird meals, the higher the resulting blood lead. This clear relationship points to lead shot as the dominating lead source to people in Greenland. - Birds hunted with lead shot and consumed are a source of lead in human blood.

  17. Determination of lead isotopic composition of airborne particulate matter by ICPMS: implications for lead atmospheric emissions in Canada

    International Nuclear Information System (INIS)

    Celo, V.; Dabek-Zlotorzynska, E.

    2009-01-01

    Full text: Quadrupole ICPMS was used for determination of trace metal concentrations and lead isotopic composition in fine particulate matter (PM 2.5 ) collected at selected sites within the Canadian National Air Pollution Surveillance network, from February 2005 to February 2007. High enrichment factors indicated that lead is mostly of anthropogenic origin and consequently, the lead isotopic composition is directly related to that of pollution sources. The 206 Pb/ 207 Pb and 208 Pb/ 207 Pb ratios were measured and the results were compared to the isotopic signatures of lead from different sources. Various approaches were used to assess the impact of relevant sources and the meteorological conditions in the occurrence and distribution of lead in Canadian atmospheric aerosols. (author)

  18. Historical record of lead accumulation and source in the tidal flat of Haizhou Bay, Yellow Sea: Insights from lead isotopes

    International Nuclear Information System (INIS)

    Zhang, Rui; Guan, Minglei; Shu, Yujie; Shen, Liya; Chen, Xixi; Zhang, Fan; Li, Tiegang

    2016-01-01

    In order to investigate the historical records of lead contamination and source in coastal region of Haizhou Bay, Yellow Sea, a sediment core was collected from tidal flat, dated by 210 Pb and 137 Cs. Lead and its stable isotopic ratios were determined. The profiles of enrichment factor (EF) and Pb isotope ratios showed increasing trend upward throughout the core, correlating closely with the experience of a rapid economic and industrial development of the catchment. According to Pb isotopic ratios, coal combustion emission mainly contributed to the Pb burden in sediments. Based on end-member model, coal combustion emission dominated anthropogenic Pb sources in recent decades contributing from 48% to 67% in sediment. And the contribution of leaded gasoline was lower than 20%. A stable increase of coal combustion source was found in sediment core, while the contribution of leaded gasoline had declined recently, with the phase-out of leaded gasoline in China. - Highlights: •Pb contamination in tidal flat of Haizhou Bay was chronicled by a sediment core. •The coal combustion source dominated Pb contamination of Haizhou Bay. •Coal combustion source showed an increasing trend in four decades in Haizhou Bay.

  19. Lead isotopes reveal different sources of lead in balsamic and other vinegars

    International Nuclear Information System (INIS)

    Ndung'u, Kuria; Hibdon, Sharon; Veron, Alain; Flegal, A. Russell

    2011-01-01

    Fifty-eight brands of balsamic vinegars were analyzed for lead concentrations and isotopic compositions ( 204 Pb, 206 Pb, 207 Pb, and 208 Pb) to test the findings of a previous study indicating relatively high levels of lead contamination in some of those vinegars - more than two thirds (70%) of them exceeded California's State Maximum Level (34 μg/L) based on consumption rates ≥ 0.5 μg Pb per day. The Lead isotopic fingerprints of all those vinegars with high lead concentrations were then found to be primarily anthropogenic. This isotopic analysis unquestionably reveals multiple contamination sources including atmospheric pollutant Pb and an unidentified contamination source, likely occurring after grape harvest. Organically grown grape vinegars display the same Pb content and isotopic signatures as other vinegars. This implies that pesticides might not be a significant source of pollutant Pb in vinegars. A significant post-harvest contamination would be inherited from chemicals added during production and/or material used during transport, processing or storage of these vinegars. This is consistent with the highest Pb levels being found in aged vinegars (112 ± 112 μg/L) in contrast to other vinegars (41.6 ± 28.9 μg/L) suggesting contamination during storage. It is, therefore, projected that lead levels in most vinegars, especially aged balsamic and wine vinegars, will decrease with improvements in their manufacture and storage processes consequential to recent concerns of elevated levels of lead in some vinegars. - Highlights: → First extensive study on content and possible sources of lead in balsamic vinegars. → Half of the vinegars exceed California's State Maximum Level for human consumption. → Lead content in vinegars seems to be mainly post-harvest from industrial processes.

  20. Lead in game birds in Denmark - levels and sources

    DEFF Research Database (Denmark)

    Kanstrup, Niels

    2012-01-01

    In June 2008, the National Food Agency contacted Bjarne Frost Vildt against the background that the Danish surveillance of heavy metals in food (EU Directive 96/23 of 29 April 1996) had, for several years, shown elevated lead levels in game meat. These elevated levels exceeded the official...... project to identify the source of lead in game meat. In July 2008, the Danish Academy of Hunting was tasked to design and carry out the investigation, in cooperation with the Veterinary Institute (Technical University of Denmark) and Food Region North (Ministry of Food, Agriculture and Fisheries....../2009 and 2009/2010 may be driven by three The biggest Danish butchery for game meat different reasons: reduced illegal use of lead shot due to the campaign initiated in 2008; reduced concentration of lead in bismuth shot (2009/2010) due to the conclusions of this study; and/or reluctance to deliver pheasants...

  1. Identification of lead sources in residential environments: Sydney Australia

    International Nuclear Information System (INIS)

    Laidlaw, M.A.S.; Zahran, S.; Pingitore, N.; Clague, J.; Devlin, G.; Taylor, M.P.

    2014-01-01

    Interior and exterior dust, soil and paint were analysed at five brick urban Sydney homes over 15 months to evaluate temporal variations and discriminate sources of lead (Pb) exposure. Exterior dust gauge Pb loading rates (μg/m 2 /28 days), interior vacuum dust Pb concentrations (mg/kg) and interior petri-dish Pb loading rates (μg/m 2 /28 days), were correlated positively with soil Pb concentrations. Exterior dust gauge Pb loading rates and interior vacuum dust Pb concentrations peaked in the summer. Lead isotope and Pb speciation (XAS) were analysed in soil and vacuum dust samples from three of the five houses that had elevated Pb concentrations. Results show that the source of interior dust lead was primarily from soil in two of the three houses and from soil and Pb paint in the third home. IEUBK child blood Pb modelling predicts that children's blood Pb levels could exceed 5 μg/dL in two of the five houses. -- Highlights: • Exterior Pb loading and interior Pb dust loading and concentrations correlate with soil Pb. • Exterior dust gauge Pb loading rates and interior vacuum dust Pb concentrations peak in the summer. • Interior dust lead came from soil in two of the three houses and from soil and Pb paint in the third home. • Modelling predicts that children's blood Pb levels could exceed 5 μg/dL in two of the five houses. -- Interior and exterior dust, soil and paint were analysed at five brick urban Sydney homes over 15 months to evaluate temporal variations and discriminate sources of lead (Pb) exposure

  2. Levels and source apportionment of children's lead exposure: could urinary lead be used to identify the levels and sources of children's lead pollution?

    Science.gov (United States)

    Cao, Suzhen; Duan, Xiaoli; Zhao, Xiuge; Wang, Beibei; Ma, Jin; Fan, Delong; Sun, Chengye; He, Bin; Wei, Fusheng; Jiang, Guibin

    2015-04-01

    As a highly toxic heavy metal, the pollution and exposure risks of lead are of widespread concern for human health. However, the collection of blood samples for use as an indicator of lead pollution is not always feasible in most cohort or longitudinal studies, especially those involving children health. To evaluate the potential use of urinary lead as an indicator of exposure levels and source apportionment, accompanying with environmental media samples, lead concentrations and isotopic measurements (expressed as (207)Pb/(206)Pb, (208)Pb/(206)Pb and (204)Pb/(206)Pb) were investigated and compared between blood and urine from children living in the vicinities of a typical coking plant and lead-acid battery factory. The results showed urinary lead might not be a preferable proxy for estimating blood lead levels. Fortunately, urinary lead isotopic measurements could be used as an alternative for identifying the sources of children's lead exposure, which coincided well with the blood lead isotope ratio analysis. Copyright © 2015 Elsevier Ltd. All rights reserved.

  3. Determination of 210Pb activity concentration in lead shielding

    International Nuclear Information System (INIS)

    Slivka, J.; Mrdja, D.; Varga, E.; Veskovic, M.

    2005-01-01

    210 Pb is concentrated during the separation lead from the ore and therefore it is the main pollutant of lead products. The content of this isotope limits the applicability of lead for low-level shielding of gamma spectrometers. In this paper, a new method for the determination of 210 Pb activity concentration in lead shielding from 46.5 keV gamma line intensity is presented. (author) [sr

  4. Characterization of sources of lead in the urban air of Asia using ratios of stable lead isotopes

    Energy Technology Data Exchange (ETDEWEB)

    Mukai, H.; Furuta, N.; Fujii, T.; Ambe, Y.; Sakamoto, K.; Hashimoto, Y. (National Institute of Environmental Studies, Tsukuba (Japan). Environmental Chemistry Division)

    1993-07-01

    Airborne particulate matter was collected at urban sites in six Asian countries (Japan, South Korea, China, Thailand, Sri Lanka, and Indonesia), and the stable lead isotope ratios were measured. Some source-related materials, such as coal and leaded gasoline, were also analyzed and compared to the ratios observed in airborne lead. Airborne lead isotope ratios differed considerably from each other, and these differences corresponded to differences in the regional source of lead. Leaded gasoline was still the primary source of lead in some cities in Asia, and the lead isotope ratios were strongly influenced by those of leaded gasoline. In Chinese and Korean cities, however, the considerable effect from coal combustion and industrial activity was also observed in their isotope ratios, despite leaded gasoline use. On the other hand, only refuse incineration was a possible single source of lead in Japanese air from the view of lead isotope ratios. 49 refs., 13 figs., 3 tabs.

  5. Studies in the determination of lead isotope ratios by inductively coupled plasma mass spectrometry

    International Nuclear Information System (INIS)

    Date, A.R.; Yuk Ying Cheung

    1987-01-01

    The application of ICP-MS to the determination of lead isotope ratios in geological materials is described. Data presented for a series of lead mineral concentrates are compared with reference values obtained by conventional solid source thermal ionisation mass spectrometry. The simultaneous determination of lead isotope ratios and trace elements is carried out in a rapid analysis mode. The application of an electrothermal vaporisation technique for small solution aliquots is described. Lead isotope ratio data for the United States Geological Survey standard reference silicate rock BCR-1, obtained without separation of lead from the matrix, are compared with previously published values obtained after separation. (author)

  6. Determination of cadmium, lead and mercury residual levels in meat ...

    African Journals Online (AJOL)

    Determination of cadmium, lead and mercury residual levels in meat of canned light tuna ( Katsuwonus pelamis and Thunnus albacares ) and fresh little tunny ( Euthynnus alletteratus ) in Libya. ... Surveillance for mercury (Hg), lead (Pb) and cadmium (Cd) contamination in tuna products is crucial for consumer food safety.

  7. Sensitivity of in vivo X-ray fluorescence determination of skeletal lead stores

    International Nuclear Information System (INIS)

    Sokas, R.K.; Besarab, A.; McDiarmid, M.A.; Shapiro, I.M.; Bloch, P.

    1990-01-01

    Eighteen patients with known past occupational lead exposure underwent parenteral diagnostic chelation with ethylenediaminetetraacetic acid and x-ray fluorescent determination of in vivo skeletal lead stores at the distal styloid process of the ulna and at the temporal base bone using a cobalt 57 source and measuring lead Ka x-rays. X-ray fluorescent lead measurements in both locations correlated with results of diagnostic chelation. Using a post-chelation urinary excretion of greater than 600 micrograms lead/24 h as the definition of high-lead stores, sensitivity of x-ray fluorescence at the wrist and temple was 56% and 39%, respectively

  8. Surma eye cosmetic in Afghanistan: a potential source of lead toxicity in children.

    Science.gov (United States)

    McMichael, J R; Stoff, B K

    2018-02-01

    Surma is a traditional eye cosmetic used as an eyeliner for infants in Afghanistan, as well as in many other countries in Asia, the Middle East, and Africa. Surma has been reported to contain lead and to be a potential source of lead toxicity in children, which can lead to permanent damage to multiple organ systems. To our knowledge, assessment for lead in surma found in Afghanistan has not been performed. We determined the quantitative lead content of a convenience sample of 10 surma products acquired in Afghanistan. Analysis revealed that 70% of surma samples contained high levels of lead (range 35-83%). The remaining samples contained low levels of lead (range 0.04-0.17%). The majority of surma samples contained very high levels of lead, a troubling finding that could potentially correlate with lead toxicity in Afghan children. Making available lead-free surma alternatives and providing health education, for both healthcare professionals and the general population, in locations where surma use is prevalent and for those involved in care of refugees and immigrants from Afghanistan, may be strategies to prevent lead poisoning in children. What is Known: • Surma is a traditional cosmetic used as an eyeliner for infants in Afghanistan as well as in many countries in Asia, the Middle East, and Africa. • Surma has been reported to contain lead and to be a source of lead toxicity in children. What is New: • Assessment for lead content in surma found in Afghanistan has not been performed. • In this convenience sample of 10 surma products acquired in Afghanistan, 70% contained very high levels of lead.

  9. Determining Childhood Blood Lead Level Screening Compliance Among Physicians.

    Science.gov (United States)

    Haboush-Deloye, Amanda; Marquez, Erika R; Gerstenberger, Shawn L

    2017-08-01

    Childhood Lead Poisoning Prevention Programs throughout the U.S. have addressed childhood lead poisoning by implementing primary and secondary prevention efforts. While many programs have helped increase screening rates, in some states children under the age of six still have not been tested for lead. This study aims to identify the barriers to childhood blood lead testing and develop a strategy to increase the number of children tested. Clark County physicians who work with children six and under were surveyed about blood lead level (BLL) testing practices, particularly, adherence to Centers for Disease Control and Prevention (CDC) guidelines, and parental compliance with orders to have their children tested to determine their blood lead levels. In addition, select in-person interviews were conducted with physicians who reported high parental compliance to identify best practices and barriers. Of the 77 physicians that provided data, 48% indicated they did not follow CDC guideline compared to 52% who follow guidelines. 18 of the 30 (or 60%) physicians reported more than 80% of parents complied with doctor recommended BLL testing. Twelve physicians identified cost, lack of insurance, and absence of symptomology as persistent barriers to lead screening. This study identified barriers to childhood lead screening including inadequate parental adherence to physician-ordered screenings and physician non-compliance with screening recommendations are two primary contributors. Addressing these issues could increase screening in children and reduce the risk of lead poisoning.

  10. Determination of Lead in Blood by Atomic Absorption Spectrophotometry1

    Science.gov (United States)

    Selander, Stig; Cramér, Kim

    1968-01-01

    Lead in blood was determined by atomic absorption spectrophotometry, using a wet ashing procedure and a procedure in which the proteins were precipitated with trichloroacetic acid. In both methods the lead was extracted into isobutylmethylketone before measurement, using ammonium pyrrolidine dithiocarbamate as chelator. The simpler precipitation procedure was shown to give results identical with those obtained with the ashing technique. In addition, blood specimens were examined by the precipitation method and by spectral analysis, which method includes wet ashing of the samples, with good agreement. All analyses were done on blood samples from `normal' persons or from lead-exposed workers, and no additions of inorganic lead were made. The relatively simple protein precipitation technique gave accurate results and is suitable for the large-scale control of lead-exposed workers. PMID:5663425

  11. Determination of Lead in Urine by Atomic Absorption Spectrophotometry1

    Science.gov (United States)

    Selander, Stig; Cramé, Kim

    1968-01-01

    A method for the determination of lead in urine by means of atomic absorption spectrophotometry (AAS) is described. A combination of wet ashing and extraction with ammonium pyrrolidine dithiocarbamate into isobutylmethylketone was used. The sensitivity was about 0·02 μg./ml. for 1% absorption, and the detection limit was about 0·02 μg./ml. with an instrumental setting convenient for routine analyses of urines. Using the scale expansion technique, the detection limit was below 0·01 μg./ml., but it was found easier to determine urinary lead concentrations below 0·05 μg./ml. by concentrating the lead in the organic solvent by increasing the volume of urine or decreasing that of the solvent. The method was applied to fresh urines, stored urines, and to urines, obtained during treatment with chelating agents, of patients with lead poisoning. Urines with added inorganic lead were not used. The results agreed well with those obtained with a colorimetric dithizone extraction method (r = 0·989). The AAS method is somewhat more simple and allows the determination of smaller lead concentrations. PMID:5647975

  12. Determination of lead and radioactivity in cosmetics products: Hazard assessment

    Directory of Open Access Journals (Sweden)

    Medhat Moustafa E.

    2015-01-01

    Full Text Available In the proposed work, an investigation on hazard assessment by lead element and natural radioactivity in cosmetic samples collected from various countries is presented. These samples were face powder, eyebrow paint and henna. The lead element in cosmetic samples was determined using particle-induced X-ray emission. Maximum natural radioactivity concentrations of 226Ra and 40K were found in khol and make-up cosmetic samples, respectively. The qualitative analysis of cosmetic samples showed that lead is the most toxic element found in eyebrow paint samples.

  13. Constraining recent lead pollution sources in the North Pacific using ice core stable lead isotopes

    Science.gov (United States)

    Gross, B. H.; Kreutz, K. J.; Osterberg, E. C.; McConnell, J. R.; Handley, M.; Wake, C. P.; Yalcin, K.

    2012-08-01

    Trends and sources of lead (Pb) aerosol pollution in the North Pacific rim of North America from 1850 to 2001 are investigated using a high-resolution (subannual to annual) ice core record recovered from Eclipse Icefield (3017 masl; St. Elias Mountains, Canada). Beginning in the early 1940s, increasing Pb concentration at Eclipse Icefield occurs coevally with anthropogenic Pb deposition in central Greenland, suggesting that North American Pb pollution may have been in part or wholly responsible in both regions. Isotopic ratios (208Pb/207Pb and 206Pb/207Pb) from 1970 to 2001 confirm that a portion of the Pb deposited at Eclipse Icefield is anthropogenic, and that it represents a variable mixture of East Asian (Chinese and Japanese) emissions transported eastward across the Pacific Ocean and a North American component resulting from transient meridional atmospheric flow. Based on comparison with source material Pb isotope ratios, Chinese and North American coal combustion have likely been the primary sources of Eclipse Icefield Pb over the 1970-2001 time period. The Eclipse Icefield Pb isotope composition also implies that the North Pacific mid-troposphere is not directly impacted by transpolar atmospheric flow from Europe. Annually averaged Pb concentrations in the Eclipse Icefield ice core record show no long-term trend during 1970-2001; however, increasing208Pb/207Pb and decreasing 206Pb/207Pb ratios reflect the progressive East Asian industrialization and increase in Asian pollutant outflow. The post-1970 decrease in North American Pb emissions is likely necessary to explain the Eclipse Icefield Pb concentration time series. When compared with low (lichen) and high (Mt. Logan ice core) elevation Pb data, the Eclipse ice core record suggests a gradual increase in pollutant deposition and stronger trans-Pacific Asian contribution with rising elevation in the mountains of the North Pacific rim.

  14. Iodide-assisted total lead measurement and determination of different lead fractions in drinking water samples.

    Science.gov (United States)

    Zhang, Yuanyuan; Ng, Ding-Quan; Lin, Yi-Pin

    2012-07-01

    Lead and its compounds are toxic and can harm human health, especially the intelligence development in children. Accurate measurement of total lead present in drinking water is crucial in determining the extent of lead contamination and human exposure due to drinking water consumption. The USEPA method for total lead measurement (no. 200.8) is often used to analyze lead levels in drinking water. However, in the presence of high concentration of the tetravalent lead corrosion product PbO(2), the USEPA method was not able to fully recover particulate lead due to incomplete dissolution of PbO(2) particles during strong acid digestion. In this study, a new procedure that integrates membrane separation, iodometric PbO(2) measurement, strong acid digestion and ICP-MS measurement was proposed and evaluated for accurate total lead measurement and quantification of different lead fractions including soluble Pb(2+), particulate Pb(II) carbonate and PbO(2) in drinking water samples. The proposed procedure was evaluated using drinking water reconstituted with spiked Pb(2+), spiked particulate Pb(II) carbonate and in situ formed or spiked PbO(2). Recovery tests showed that the proposed procedure and the USEPA method can achieve 93-112% and 86-103% recoveries respectively for samples containing low PbO(2) concentrations (0.018-0.076 mg Pb per L). For samples containing higher concentrations of PbO(2) (0.089-1.316 mg Pb per L), the USEPA method failed to meet the recovery requirement for total lead (85-115%) while the proposed method can achieve satisfactory recoveries (91-111%) and differentiate the soluble Pb(2+), particulate Pb(II) carbonate and PbO(2).

  15. Determination of lead at nanogram level in water samples by ...

    African Journals Online (AJOL)

    A novel method of chemistry applicable to the determination of trace lead in water samples based on the resonance light scattering (RLS) technique has been developed. In dilute phosphoric acid medium, in the presence of a large excess of I-, Pb(II) can form [PbI4]2-, which further reacts with tetrabutyl ammonium bromide ...

  16. Lead isotope ratios as a tracer for lead contamination sources: A lake Andong case study

    Directory of Open Access Journals (Sweden)

    Kim Y. H

    2013-04-01

    Full Text Available The objective of this study was to evaluate stable Pb isotope signatures as a tracer for Pb contamination in Lake Andong. For Pb isotope analysis, we collected water and sediment from Lake Andong, particles in the air, soils, and stream water, mine tailings, sludge and wastewater from zinc smelting around lake Andong watershed. The results showed that Pb isotope ratios (206Pb/204Pb, 207Pb/204Pb, and 208Pb/204Pb for zinc concentrate were 18.809 ± 0.322, 15.650 ± 0.062, and 38.728 ± 0.421, respectively. In wastewater, isotopic ratio values (206Pb/204Pb, 207Pb/204Pb, and 208Pb/204Pb were 17.363 ± 0.133, 15.550 ± 0.025, and 37.217 ± 0.092, respectively. Additionally, isotopic ratio values (206Pb/204Pb, 207Pb/204Pb, and 208Pb/204Pb for sludge were 17.515 ± 0.155, 15.537 ± 0.018, and 37.357 ± 0.173, respectively. These values were similar to those in zinc and lead concentrate originated from Canada and South America. In contrast, Pb isotope ratios of soil, tailings and sediment from Lake Andong were similar to those of Korean ore. Atmospheric particles showed different patterns of Pb isotope ratios from sediments, soils, and zinc smelting and this needs further investigation in order to identify atmospheric Pb sources.

  17. Determination of lead in mother's milk by atomic absorption spectroscopy

    International Nuclear Information System (INIS)

    Bandarchian, F.; Assadian, F

    2002-01-01

    With due attention to increasing air pollution specially the lead amount that is generated from gasoline burning in automobiles, it seems that it is necessary to control the amount of it continuously. Because Pb has an easy absorbability to body and also damages the nervous system. For this reason determination of it in mother's milk has a special importance. In this research, the milks of 15 mothers twice a day were examined and the concentration of Pb were determined by atomic absorption spectroscopy. In accordance the international organization, the permissible amount in body is 0.05 ppm. Fortunately, the obtained data was less than of it and it showed the absorbance of lead by babies is insignificant

  18. Lead isotope identification of sources of galena from some prehistoric Indian sites in Ontario, Canada

    International Nuclear Information System (INIS)

    Farquhar, R.M.; Fletcher, I.R.

    1980-01-01

    Lead isotopic compositions of 12 galenas from five late Archaic-initial Woodland grave and habitation sites in southern Ontario have made it possible to determine the most likely source areas for the galenas. For one of the oldest sites (Finlan), the most likely source is in the southwestern Upper Mississippi Valley (Wisconsin-Illinois-Iowa) mineral district. The seven Finlan galenas exhibit a range of isotopic ratios; three of the largest specimens have substantial isotopic variations (up to 1.8% in the ratio of lead-207 to lead-206) on a scale of a few centimeters. This suggests that the lead isotopic zoning ascribed to the Upper Mississippi Valley area is not sufficiently well defined to enable us to determine if all the Finlan samples were derived from a single mineral deposit. Galenas from the other sites (Constance Bay, Hind, Bruce Boyd, and Picton) most probably originated in the southeastern Ontario-northwestern New York area. Isotopic differences among the Constance Bay, Hind, and Bruce Boyd galenas, on the one hand, and the Picton galena, on the other, suggest that at least two distinct sources in that region were exploited

  19. Determination of lead 210 in scales from industrial processes

    International Nuclear Information System (INIS)

    Faria, Lígia S.; Moreira, Rubens M.; Kastner, Geraldo F.; Barbosa, João B.S.

    2017-01-01

    Industrial processes such as oil and gas extraction and groundwater exploitation are examples of installations that can accumulate naturally occurring radioactive materials (NORM) during the extraction and production. Lead-210 deposits in the production can be formed by the same mechanisms that occur in the environment through the support of Radon-222, (where 210 Pb is produced at 222 Rn decay) or without support, as 210 Pb. The objective of this work is to evaluate the mineralogical characteristics and determine the activity of lead-210 in the scales using the X-Ray Diffraction and Gamma Spectrometry techniques. Were analyzed fifteen samples, four scales from oil industry, ten scales from groundwater conductors and one for groundwater supply pipe. The highest activity found in the oil scale and groundwater conductors scale was 0.30 ± 0.06 Bq g -1 and 3.80 ± 0.20 Bq g -1 , respectively. (author)

  20. Determination of lead 210 in scales from industrial processes

    Energy Technology Data Exchange (ETDEWEB)

    Faria, Lígia S.; Moreira, Rubens M.; Kastner, Geraldo F.; Barbosa, João B.S., E-mail: ligsfaria@gmail.com, E-mail: rubens@cdtn.br, E-mail: gfk@cdtn.br, E-mail: jbsb@cdtn.br [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2017-11-01

    Industrial processes such as oil and gas extraction and groundwater exploitation are examples of installations that can accumulate naturally occurring radioactive materials (NORM) during the extraction and production. Lead-210 deposits in the production can be formed by the same mechanisms that occur in the environment through the support of Radon-222, (where {sup 210}Pb is produced at {sup 222}Rn decay) or without support, as {sup 210}Pb. The objective of this work is to evaluate the mineralogical characteristics and determine the activity of lead-210 in the scales using the X-Ray Diffraction and Gamma Spectrometry techniques. Were analyzed fifteen samples, four scales from oil industry, ten scales from groundwater conductors and one for groundwater supply pipe. The highest activity found in the oil scale and groundwater conductors scale was 0.30 ± 0.06 Bq g{sup -1} and 3.80 ± 0.20 Bq g{sup -1}, respectively. (author)

  1. Enzymatic determination of cadmium, zinc, and lead in plant materials

    International Nuclear Information System (INIS)

    Muginova, S.V.; Veselova, I.A.; Parova, L.M.; Shekhovtseva, T.N.

    2008-01-01

    Prospects are outlined for using the following enzymes (native and immobilized on polyurethane foam) in the rapid and highly sensitive determination of cadmium, zinc, and lead ions in plant materials (wild grass, fresh pea, and grape): horseradish peroxidase and alkaline phosphatases isolated from chicken intestine and Greenland seal small intestine. The analytical ranges of the above metals are 1x10 -3 -25; 7x10 -3 -250, and 3x10 -2 -67 mg/kg dry matter, respectively. The enzymatic determination procedures developed are based on the inhibiting effect of metal ions on the catalytic activity of peroxidase in the oxidation of o-dianisidine with hydrogen peroxide and alkaline phosphatases in the hydrolysis of p-nitrophenyl phosphate. The rates of enzymatic reactions were monitored spectrophotometrically or visually. In the analysis of plant extracts, their high acidity was diminished by choosing optimum dilution factors and pH values for test samples and the nature and concentration of a buffer solution. The interference of iron(III) was removed by introducing a 0.1 M tartaric acid solution into the indicator reaction. The accuracy of the results of the enzymatic determination of cadmium, zinc, and lead in plant materials was supported by atomic absorption spectrometry and anodic stripping voltammetry [ru

  2. Children’s Blood Lead Seasonality in Flint, Michigan (USA), and Soil-Sourced Lead Hazard Risks

    Science.gov (United States)

    Laidlaw, Mark A.S.; Filippelli, Gabriel M.; Sadler, Richard C.; Gonzales, Christopher R.; Ball, Andrew S.; Mielke, Howard W.

    2016-01-01

    In Flint; MI; USA; a public health crisis resulted from the switching of the water supply from Lake Huron to a more corrosive source from the Flint River in April 2014; which caused lead to leach from water lines. Between 2010 and 2015; Flint area children’s average blood lead patterns display consistent peaks in the third quarter of the year. The third quarter blood lead peaks displayed a declining trend between 2010 and 2013; then rose abruptly between the third quarters of 2013 from 3.6% blood lead levels ≥5 µg/dL to a peak of about 7% in the third quarter of 2014; an increase of approximately 50%. The percentage of blood lead level ≥5 µg/dL in the first quarter of 2015 then dropped to 2.3%; which was the same percentage as the first quarter of 2014 (prior to the Flint River water source change). The Flint quarterly blood lead level peak then rose to about 6% blood lead levels ≥ 5 µg/dL in the third quarter of 2015; and then declined to about 2.5% in the fourth quarter of 2015. Soil lead data collected by Edible Flint food collaborative reveal generally higher soil lead values in the metropolitan center for Flint; with lower values in the outskirts of the city. The questions that are not being asked is why did children’s blood lead levels display a seasonal blood lead pattern before the introduction of the new water supply in Flint; and what are the implications of these seasonal blood lead patterns? Based upon previous findings in Detroit and other North American cities we infer that resuspension to the air of lead in the form of dust from lead contaminated soils in Flint appears to be a persistent contribution to lead exposure of Flint children even before the change in the water supply from Lake Huron to the Flint River. PMID:27023578

  3. Applications of lead isotope rations for identification and apportionment on pollution sources in food

    International Nuclear Information System (INIS)

    Zhao Duoyong; Wei Yimin; Guo Boli; Wei Shuai

    2011-01-01

    Lead is one of the toxic heavy metals which can accumulate to an adverse effect level in human bodies through ingestion, inhalation or other pathways. Because of the persistent lead contamination in farmland environment, large risk exists in the primary stage of 'from farm to table' chain. Environmental media such as soils, atmospheric aerosols were the possible lead sources of agro-food. To pinpoint the pollution sources exactly, cut off the contamination pathways in time, and reduce the risk of hazard, pollution sources tracing was very important. Lead isotope ratio combined with certain models is an effective method to discriminate correctly pollution sources and calculate the individual source contributions. In this review, to provide theoretical and technical reference for controlling lead pollution in environment and food, lead pollution sources in food, tracing principle and methods of lead isotope ratios, and its applications on vegetable, tea, wine, cereal and other food products were concerned. (authors)

  4. Successful application of lead isotopes in source apportionment, legal proceedings, remediation and monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Gulson, Brian, E-mail: brian.gulson@mq.edu.au [Graduate School of the Environment, Faculty of Science, Macquarie University, Sydney, NSW 2109 (Australia); CSIRO Earth Science and Resource Engineering North Ryde, NSW 1670 (Australia); Korsch, Michael [CSIRO Earth Science and Resource Engineering North Ryde, NSW 1670 (Australia); Winchester, Wayne; Devenish, Matthew; Hobbs, Thad [Esperance Cleanup and Recovery Project, Western Australia (WA) Department of Transport, Esperance 6450 (Australia); Main, Cleve; Smith, Gerard [Animal Health Laboratory, Department of Agriculture and Food, Perth 6151, WA (Australia); Rosman, Kevin; Howearth, Lynette; Burn-Nunes, Laurie [Curtin University, Department of Imaging and Applied Physics, Bentley 6102, WA (Australia); Seow, Jimmy; Oxford, Cameron [Department of Environment and Conservation, Booragoon 6154, WA (Australia); Yun, Gracie; Gillam, Lindsay [Department of Health, East Perth 6004, WA (Australia); Crisp, Michelle [LED (Locals for Esperance Development), Esperance 6450, WA (Australia)

    2012-01-15

    In late 2006, the seaside community in Esperance Western Australia was alerted to thousands of native bird species dying. The source of the lead (Pb) was determined by Pb isotopes to derive from the handling of Pb carbonate concentrate through the Port, which began in July 2005. Concern was expressed for the impact of this on the community. Our objectives were to employ Pb isotope ratios to evaluate the source of Pb in environmental samples for use in legal proceedings, and for use in remediation and monitoring. Isotope measurements were undertaken of bird livers, plants, drinking water, soil, harbour sediments, air, bulk ceiling dust, gutter sludge, surface swabs and blood. The unique lead isotopic signature of the contaminating Pb carbonate enabled diagnostic apportionment of lead in samples. Apart from some soil and water samples, the proportion of contaminating Pb was >95% in the environmental samples. Lead isotopes were critical in resolving legal proceedings, are being used in the remediation of premises, were used in monitoring of workers involved in the decontamination of the storage facility, and monitoring transport of the concentrate through another port facility. Air samples show the continued presence of contaminant Pb, more than one year after shipping of concentrate ceased, probably arising from dust resuspension. Brief details of the comprehensive testing and cleanup of the Esperance community are provided along with the role of the Community. Lead isotopic analyses can provide significant benefits to regulatory agencies, interested parties, and the community where the signature is able to be characterised with a high degree of certainty. - Highlights: Black-Right-Pointing-Triangle Lead carbonate concentrate. Black-Right-Pointing-Triangle Successful use of Pb isotopes in identifying sources of Pb arising from transport and shipping. Black-Right-Pointing-Triangle Use of Pb isotopes in legal proceedings and their use in cleanup of residences. Black

  5. Potential containment materials for liquid-lead and lead-bismuth eutectic spallation neutron source

    International Nuclear Information System (INIS)

    Park, J.J.; Butt, D.P.; Beard, C.A.

    1997-11-01

    Lead (Pb) and lead-bismuth eutectic (44Pb-56Bi) have been the two primary candidate liquid-metal target materials for the production of spallation neutrons. Selection of a container material for the liquid-metal target will greatly affect the lifetime and safety of the target subsystem. For the lead target, niobium-1 (wt%) zirconium (Nb-1Zr) is a candidate containment material for liquid lead, but its poor oxidation resistance has been a major concern. The oxidation rate of Nb-1Zr was studied based on the calculations of thickness loss due to oxidation. According to these calculations, it appeared that uncoated Nb-1Zr may be used for a one-year operation at 900 C at P O 2 = 1 x 10 -6 torr, but the same material may not be used in argon with 5-ppm oxygen. Coating technologies to reduce the oxidation of Nb-1Zr are reviewed, as are other candidate refractory metals such as molybdenum, tantalum, and tungsten. For the Pb-Bi target, three candidate containment materials are suggested based on a literature survey of the materials compatibility and proton irradiation tests: Croloy 2-1/4, modified 9Cr-1Mo, and 12Cr-1Mo (HT-9) steel. These materials seem to be used only if the lead-bismuth is thoroughly deoxidized and treated with zirconium and magnesium

  6. The Chandra Source Catalog: Background Determination and Source Detection

    Science.gov (United States)

    McCollough, Michael; Rots, Arnold; Primini, Francis A.; Evans, Ian N.; Glotfelty, Kenny J.; Hain, Roger; Anderson, Craig S.; Bonaventura, Nina R.; Chen, Judy C.; Davis, John E.; Doe, Stephen M.; Evans, Janet D.; Fabbiano, Giuseppina; Galle, Elizabeth C.; Danny G. Gibbs, II; Grier, John D.; Hall, Diane M.; Harbo, Peter N.; He, Xiang Qun (Helen); Houck, John C.; Karovska, Margarita; Kashyap, Vinay L.; Lauer, Jennifer; McCollough, Michael L.; McDowell, Jonathan C.; Miller, Joseph B.; Mitschang, Arik W.; Morgan, Douglas L.; Mossman, Amy E.; Nichols, Joy S.; Nowak, Michael A.; Plummer, David A.; Refsdal, Brian L.; Siemiginowska, Aneta L.; Sundheim, Beth A.; Tibbetts, Michael S.; van Stone, David W.; Winkelman, Sherry L.; Zografou, Panagoula

    2009-09-01

    The Chandra Source Catalog (CSC) is a major project in which all of the pointed imaging observations taken by the Chandra X-Ray Observatory are used to generate one of the most extensive X-ray source catalog produced to date. Early in the development of the CSC it was recognized that the ability to estimate local background levels in an automated fashion would be critical for essential CSC tasks such as source detection, photometry, sensitivity estimates, and source characterization. We present a discussion of how such background maps are created directly from the Chandra data and how they are used in source detection. The general background for Chandra observations is rather smoothly varying, containing only low spatial frequency components. However, in the case of ACIS data, a high spatial frequency component is added that is due to the readout streaks of the CCD chips. We discuss how these components can be estimated reliably using the Chandra data and what limitations and caveats should be considered in their use. We will discuss the source detection algorithm used for the CSC and the effects of the background images on the detection results. We will also touch on some the Catalog Inclusion and Quality Assurance criteria applied to the source detection results. This work is supported by NASA contract NAS8-03060 (CXC).

  7. Chandra Source Catalog: Background Determination and Source Detection

    Science.gov (United States)

    McCollough, Michael L.; Rots, A. H.; Primini, F. A.; Evans, I. N.; Glotfelty, K. J.; Hain, R.; Anderson, C. S.; Bonaventura, N. R.; Chen, J. C.; Davis, J. E.; Doe, S. M.; Evans, J. D.; Fabbiano, G.; Galle, E.; Gibbs, D. G.; Grier, J. D.; Hall, D. M.; Harbo, P. N.; He, X.; Houck, J. C.; Karovska, M.; Lauer, J.; McDowell, J. C.; Miller, J. B.; Mitschang, A. W.; Morgan, D. L.; Nichols, J. S.; Nowak, M. A.; Plummer, D. A.; Refsdal, B. L.; Siemiginowska, A. L.; Sundheim, B. A.; Tibbetts, M. S.; Van Stone, D. W.; Winkelman, S. L.; Zografou, P.

    2009-01-01

    The Chandra Source Catalog (CSC) is a major project in which all of the pointed imaging observations taken by the Chandra X-Ray Observatory will used to generate the most extensive X-ray source catalog produced to date. Early in the development of the CSC it was recognized that the ability to estimate local background levels in an automated fashion would be critical for essential CSC tasks such as source detection, photometry, sensitivity estimates, and source characterization. We present a discussion of how such background maps are created directly from the Chandra data and how they are used in source detection. The general background for Chandra observations is rather smoothly varying, containing only low spatial frequency components. However, in the case of ACIS data, a high spatial frequency component is added that is due to the readout streaks of the CCD chips. We discuss how these components can be estimated reliably using the Chandra data and what limitations and caveats should be considered in their use. We will discuss the source detection algorithm used for the CSC and the effects of the background images on the detection results. We will also touch on some the Catalog Inclusion and Quality Assurance criteria applied to the source detection results. This work is supported by NASA contract NAS8-03060 (CXC).

  8. Determination of the Regional Economy Leading Sectors in Indonesia

    Directory of Open Access Journals (Sweden)

    Fitri Amalia

    2015-03-01

    Full Text Available Economic growth and its process are the main condition for the sustainability of the regional economic development. Because of the continuing population growth means economic needs also increase so that additional revenue required each year. This can be obtained by the increase in aggregate output (goods and services or the Gross Regional Domestic Product (GRDP each year. To carry out development with limited resources as a consequence should be focused to develop the sectors that provide great multiplier effect on other sectors or the whole economy. This research is focused to determine the regional leading sector of Bone Bolango as the information and considerations in planning economic development. Location Quotient (LQ and Shift Share are tools of analysis. Location Quotient analysis indicates agriculture, manufacture, finance, leasing and corporate services are base sectors in the Bone Bolango district. Shift Share analysis indicates that the competitive sectors are finance, leasing and corporate services. The results of the analysis based on three analysis tools indicate that the leading sector with the criteria developed, base, and competitive is finance and services sector.

  9. Using trace element content and lead isotopic composition to assess sources of PM in Tijuana, Mexico

    Science.gov (United States)

    Salcedo, D.; Castro, T.; Bernal, J. P.; Almanza-Veloz, V.; Zavala, M.; González-Castillo, E.; Saavedra, M. I.; Perez-Arvízu, O.; Díaz-Trujillo, G. C.; Molina, L. T.

    2016-05-01

    PM2.5 samples were collected at two urban sites (Parque Morelos (PQM) and CECyTE (CEC)) in Tijuana during the Cal-Mex campaign from May 24 to June 5, 2010. Concentration of trace elements (Mg, Al, Ti, V, Mn, Fe, Co, Ni, Zn, Cu, Ga, As, Se, Rb, Sr, Mo, Cd, Sn, Sb, Ba, La, Ce, and Pb), and Pb isotopic composition were determined in order to study the sources of PM impacting each site. Other chemical analysis (gravimetric, elemental and organic carbon (EC/OC), and polycyclic aromatic hydrocarbons (PAHs)), were also performed. Finally, back-trajectories were calculated to facilitate the interpretation of the chemical data. Trace elements results show that CEC is a receptor site affected by mixed regional sources: sea salt, mineral, urban, and industrial. On the other hand, PQM seems to be impacted mainly by local sources. In particular, Pb at CEC is of anthropogenic, as well as crustal origin. This conclusion is supported by the lead isotopic composition, whose values are consistent with a combination of lead extracted from US mines, and lead from bedrocks in the Mexican Sierras. Some of the time variability observed can be explained using the back-trajectories.

  10. Vision problems are a leading source of modifiable health expenditures.

    Science.gov (United States)

    Rein, David B

    2013-12-13

    According to recent studies, visual problems represent one of the top contributors to economic health burden in the United States. This burden is divided nearly equally between direct expenditures for the care and treatment of visual problems, and the indirect costs of outcomes caused by low vision, including productivity losses, the cost of care, and incremental nursing home placements. A large amount of academic research is devoted to visual science, the biology of the visual system, and the medical treatment of visual disorders. Compared to the burden, a disproportionate share of this research is devoted to the study of retinal disorders and glaucoma. This is understandable, as research into the retina and optic nerve has the potential to unlock fundamental insights into the nature of sight and visual cognition. However, population visual health and the functionality that depends upon it also may benefit greatly from additional research into areas of prevention, rehabilitation, and adaptation. In addition, comparative research into the benefits of resource allocation across prevention, treatment, and rehabilitative resources could lead to improvements in population health.

  11. Lead isotopic fingerprinting of aerosols to characterize the sources of atmospheric lead in an industrial city of India

    Science.gov (United States)

    Sen, Indra S.; Bizimis, Michael; Tripathi, Sachchida Nand; Paul, Debajyoti

    2016-03-01

    Anthropogenic Pb in the environment is primarily sourced from combustion of fossil fuel and high-temperature industries such as smelters. Identifying the sources and pathways of anthropogenic Pb in the environment is important because Pb toxicity is known to have adverse effects on human health. Pb pollution sources for America, Europe, and China are well documented. However, sources of atmospheric Pb are unknown in India, particularly after leaded gasoline was phased out in 2000. India has a developing economy with a rapidly emerging automobile and high temperature industry, and anthropogenic Pb emission is expected to rise in the next decade. In this study, we report on the Pb-isotope compositions and trace metal ratios of airborne particulates collected in Kanpur, a large city in northern part of India. The study shows that the PM10 aerosols had elevated concentration of Cd, Pb, Zn, As, and Cu in the Kanpur area, however their concentrations are well below the United States Environmental Protection Agency chronic exposure limit. Lead isotopic and trace metal data reveal industrial emission as the plausible source of anthropogenic Pb in the atmosphere in Kanpur. However, Pb isotopic compositions of potential source end-members are required to fully evaluate Pb contamination in India over time. This is the first study that characterizes the isotopic composition of atmospheric Pb in an Indian city after leaded gasoline was phased out by 2000.

  12. Anthropogenic lead concentrations and sources in Baltic Sea sediments based on lead isotopic composition

    International Nuclear Information System (INIS)

    Zaborska, Agata

    2014-01-01

    Highlights: • Pb concentrations reach even 147 μg/g at Gdansk Basin sediments. • Marine sediments deposited before 1860 are not contaminated by Pb. • Contemporary inventories of anthropogenic Pb in marine sediments was of 0.5–11 g for m 2 . • The lowest 206 Pb/ 207 Pb (1.165) were measured in sediments deposited between 1970s–90s. • Coal burning was always the most important Pb source in Poland. - Abstract: The Gulf of Gdańsk is influenced by heavy metals of anthropogenic origin. In this study, temporal concentration changes of Pb, Zn, Cd, and Cu were studied in six, 50 cm long sediment cores. The main aim of the study was to concentrate on the history of Pb fluxes and Pb isotopic composition ( 206 Pb/ 207 Pb and 208 Pb/ 206 Pb) to trace Pb sources. The lowest Pb concentrations (19 μg g −1 ) were measured in sediments deposited circa 1860, while the highest Pb concentrations (63–147 μg g −1 ) were measured in sediments deposited between 1960s and 70s. Pre-industrial Pb fluxes were 7 Pb m 2 year −1 , while after WWII they reached 199 Pb m 2 year −1 . Highest 206 Pb/ 207 Pb ratios (∼1.22) were measured in the oldest sediment layers, and the lowest 206 Pb/ 207 Pb ratios (∼1.165) were measured in the sediments deposited in 1970s–90s. During the period of highest Pb contamination, the anthropogenic Pb fraction reached up to 93%. A general discussion of the Pb sources, emissions, and loads for Poland is included

  13. Lead-Bismuth-Eutectic Spallation Neutron Source for Nuclear Transmuter

    International Nuclear Information System (INIS)

    Gohar, Y.; Herceg, J.; Krajtl, L.; Micklich, B.; Pointer, D.; Saiveau, J.; Sofu, T.; Finck, P.

    2002-01-01

    A lead-bismuth eutectic (LBE) spallation target design concept has been developed for the subcritical multiplier (SCM) design of the accelerator-driven test facility (ADTF). The design is based on a coaxial geometrical configuration, which has been carefully analyzed and designed to achieve an optimum performance. The target design description, the results from the parametric studies, and the design analyses including neutronics, heat transfer, and hydraulics analyses are given in this paper. A detailed MCNPX geometrical model for the target has been developed to generate heating rates and nuclear responses in the structural material for the design process. The beam has a uniform distribution of 600 MeV protons and 5-MW total power. A small LBE buffer is optimized to reduce the irradiation damage in the SCM fuel elements from the scatter protons and the high-energy neutrons, to maximize the neutron yield to the SCM operation, and to provide inlet and outlet manifolds for the LBE coolant. A special attention has been given to the target window design to enhance its lifetime. The window volumetric heating is 766 W/cm 3 relative to 750 W/cm 3 in LBE for a 40-μA/cm 2 current density. The results show that the nuclear heating from the proton beam diminishes at about 32 cm along the beam axis in the LBE target material. The neutron contribution to the atomic displacement is in the range of 94 to ∼100% for the structure material outside the proton beam path. In the beam window, the neutron contribution is ∼74% and the proton beam is responsible for more than 95% of the total gas production. The proton contribution to the gas production vanishes outside the beam path. The LBE average velocity is ∼2 m/s. The heat transfer and the hydraulics analyses have been iterated to reduce the maximum temperature and the thermal stress level in the target window to enhance its operating life. (authors)

  14. Identification of the sources of metal (lead) contamination in drinking waters in north-eastern Tasmania using lead isotopic compositions.

    Science.gov (United States)

    Harvey, P J; Handley, H K; Taylor, M P

    2015-08-01

    This study utilises a range of scientific approaches, including lead isotopic compositions, to differentiate unknown sources of ongoing lead contamination of a drinking water supply in north-eastern Tasmania, Australia. Drinking water lead concentrations are elevated above the Australian Drinking Water Guideline (10 μg/L), reaching 540 μg/L in the supply network. Water lead isotopic compositions from the town of Pioneer ((208)Pb/(207)Pb 2.406, (206)Pb/(207)Pb 1.144 to (208)Pb/(207)Pb 2.360, (206)Pb/(207)Pb 1.094) and Ringarooma ((208)Pb/(207)Pb 2.398, (206)Pb/(207)Pb 1.117) are markedly different from the local bedrock ((208)Pb/(207)Pb 2.496, (206)Pb/(207)Pb 1.237). The data show that the lead in the local waters is sourced from a combination of dilapidated drinking water infrastructure, including lead jointed pipelines, end-of-life polyvinyl chloride pipes and household plumbing. Drinking water is being inadvertently contaminated by aging infrastructure, and it is an issue that warrants investigation to limit the burden of disease from lead exposure.

  15. Determination of lead in rice grains by solid sampling HR-CS GFAAS.

    Science.gov (United States)

    Gunduz, Sema; Akman, Suleyman

    2013-12-01

    A study was performed for the determination of lead in rice grains directly by solid sampling high resolution continuum source graphite furnace atomic absorption spectrometry (HR-CS GFAAS) without digesting sample. The effects of sample amount, pyrolysis/atomization temperatures on the determination of lead in rice were investigated and optimized using a certificated rice flour. The lead concentrations were determined applying 800 °C of pyrolysis and 1800 °C of atomization temperatures without modifier. LOD (N=10, 3σ) and characteristic mass were 2.3 μg kg(-1) and 8.1 pg, respectively. The certified lead value of a rice flour CRM was found in its uncertainity limits. The lead contents of various rice samples obtained from markets in Turkey were between 0.009 and 0.162 mg kg(-1) which are in acceptable range. The average lead concentrations in various rice grains taken from the same package were significantly different from each other. Copyright © 2013 Elsevier Ltd. All rights reserved.

  16. Sulfide precursor concentration and lead source effect on PbS thin films properties

    International Nuclear Information System (INIS)

    Beddek, L.; Messaoudi, M.; Attaf, N.; Aida, M.S.; Bougdira, J.

    2016-01-01

    Lead sulfide (PbS) thin films were synthesized using chemical bath deposition (CBD). Bath solutions are formed of various concentrations of thiourea, sulfide source, ranged from 0.6 to 1.2 M and two different salts as Pb source (lead acetate and lead nitrate). From the growth mechanism, we inferred that PbS is formed through the ion by ion process when using acetate lead source, while, using nitrate source yields to films growth through the complex-decomposition process. Due to the difference in the involved growth process, lead acetate produces films with larger crystallite size (from 4 to 16 nm), smooth and dense films. However, lead nitrate produces rough films with smaller crystallite size (from 1 to 4 nm). Increasing the thiourea concentration results in crystallinity improvement when using lead acetate and, oppositely, in crystallinity degradation when using lead nitrate. Due to the quantum effect caused by the small crystallite sizes, the films optical gap is varied from 0.5 to 0.9 eV. - Highlights: • PbS thin films were synthesized by chemical bath deposition. • Ion by ion is the growth process when using the acetate lead source. • Deposition process is by complex-decomposition when using nitrate source. • Lead acetate yields to dense films with larger crystallite size. • Lead nitrate produces rough films with smaller crystallite size.

  17. Sulfide precursor concentration and lead source effect on PbS thin films properties

    Energy Technology Data Exchange (ETDEWEB)

    Beddek, L.; Messaoudi, M.; Attaf, N. [Laboratoire Couche Minces et Interfaces, Université frères Mentouri Constantine, 25000, Constantine (Algeria); Aida, M.S., E-mail: aida_salah2@yahoo.fr [Laboratoire Couche Minces et Interfaces, Université frères Mentouri Constantine, 25000, Constantine (Algeria); Bougdira, J. [Université de Lorraine, Institut Jean Lamour UMR 7198, Vandoeuvre 54506 (France)

    2016-05-05

    Lead sulfide (PbS) thin films were synthesized using chemical bath deposition (CBD). Bath solutions are formed of various concentrations of thiourea, sulfide source, ranged from 0.6 to 1.2 M and two different salts as Pb source (lead acetate and lead nitrate). From the growth mechanism, we inferred that PbS is formed through the ion by ion process when using acetate lead source, while, using nitrate source yields to films growth through the complex-decomposition process. Due to the difference in the involved growth process, lead acetate produces films with larger crystallite size (from 4 to 16 nm), smooth and dense films. However, lead nitrate produces rough films with smaller crystallite size (from 1 to 4 nm). Increasing the thiourea concentration results in crystallinity improvement when using lead acetate and, oppositely, in crystallinity degradation when using lead nitrate. Due to the quantum effect caused by the small crystallite sizes, the films optical gap is varied from 0.5 to 0.9 eV. - Highlights: • PbS thin films were synthesized by chemical bath deposition. • Ion by ion is the growth process when using the acetate lead source. • Deposition process is by complex-decomposition when using nitrate source. • Lead acetate yields to dense films with larger crystallite size. • Lead nitrate produces rough films with smaller crystallite size.

  18. The isotopic composition of lead in man and the environment in Finland: isotope ratios of lead as indicators of pollutant source

    International Nuclear Information System (INIS)

    Keinonen, M.

    1989-01-01

    The isotopic composition of lead was determined in samples from the Helsinki area: in emission sources (gasoline, incinerator and lead smelter emissions, coal), in sources of intake to man (air, diet), in samples representing long-term deposition (lichen, soil, lake sediments) and in human tissue. The measurements of the isotope ratios 206 Pb/ 204 Pb and 206 Pb/ 207 Pb were done by thermal ionization mass spectrometry after chemical separation of lead by anion exchange and cathodic electrodeposition. The origin of lead in man and the environment in the Helsinki area was evaluated by using the differences in the measured isotope ratios as an indicator. The means of the ratios in gasoline ( 206 Pb/ 207 Pb 1.124+-0.026, 206 Pb/ 204 Pb 17.45+-0.42) and the ratios in other emission sources in Helsinki ( 206 Pb/ 207 Pb 1.149-1.226, 206 Pb/ 204 Pb 17.94-19.24) were significantly different. Lead in air samples from Helsinki (1.123+-0.013) could be attributed to gasoline, as lead in soil near a highway (1.136+-0.003). By contrast, isotope ratios measured in lichen (1.148+-0.006) indicated considerable amounts of lead from sources with higher 206 Pb abundances, evidently industrial sources. The isotope ratios in human liver, lung, and bone ( 206 Pb/ 207 Pb 1.142+-0.015, 1.151+-0.011, and 1.156+-0.013, respectively and 206 Pb/ 204 Pb 17.76+-0.28, 17.91+-0.20, and 17.96+-0.09, respectively) were practically the same and no significant dependence of the isotope ratios on age or concentration of lead was seen. In lake sediment cores a correlation was found between the isotope ratios, lead concentration, and depth. The non-anthropogenic lead of high isotope ratios from bedrock was the major component at depths dated older than 100 years. At the surface of the sediment atmospheric lead prevailed, with ratios similar to those of gasoline, air samples and lichen. In the post-1900 layers, anthropogenic lead made up about 40-60% of the total sedimentary lead

  19. Successful application of lead isotopes in source apportionment, legal proceedings, remediation and monitoring.

    Science.gov (United States)

    Gulson, Brian; Korsch, Michael; Winchester, Wayne; Devenish, Matthew; Hobbs, Thad; Main, Cleve; Smith, Gerard; Rosman, Kevin; Howearth, Lynette; Burn-Nunes, Laurie; Seow, Jimmy; Oxford, Cameron; Yun, Gracie; Gillam, Lindsay; Crisp, Michelle

    2012-01-01

    In late 2006, the seaside community in Esperance Western Australia was alerted to thousands of native bird species dying. The source of the lead (Pb) was determined by Pb isotopes to derive from the handling of Pb carbonate concentrate through the Port, which began in July 2005. Concern was expressed for the impact of this on the community. Our objectives were to employ Pb isotope ratios to evaluate the source of Pb in environmental samples for use in legal proceedings, and for use in remediation and monitoring. Isotope measurements were undertaken of bird livers, plants, drinking water, soil, harbour sediments, air, bulk ceiling dust, gutter sludge, surface swabs and blood. The unique lead isotopic signature of the contaminating Pb carbonate enabled diagnostic apportionment of lead in samples. Apart from some soil and water samples, the proportion of contaminating Pb was >95% in the environmental samples. Lead isotopes were critical in resolving legal proceedings, are being used in the remediation of premises, were used in monitoring of workers involved in the decontamination of the storage facility, and monitoring transport of the concentrate through another port facility. Air samples show the continued presence of contaminant Pb, more than one year after shipping of concentrate ceased, probably arising from dust resuspension. Brief details of the comprehensive testing and cleanup of the Esperance community are provided along with the role of the Community. Lead isotopic analyses can provide significant benefits to regulatory agencies, interested parties, and the community where the signature is able to be characterised with a high degree of certainty. Crown Copyright © 2011. Published by Elsevier Inc. All rights reserved.

  20. Cadmium, mercury, and lead in kidney cortex of living kidney donors: Impact of different exposure sources,

    Energy Technology Data Exchange (ETDEWEB)

    Barregard, Lars, E-mail: lars.barregard@amm.gu.se [Department of Occupational and Environmental Medicine, Sahlgrenska University Hospital and University of Gothenburg, P.O. Box 414, SE 405 30 Gothenburg (Sweden); Fabricius-Lagging, Elisabeth [Department of Nephrology, Sahlgrenska University Hospital and Boras Hospital (Sweden); Lundh, Thomas [Department of Occupational and Environmental Medicine, Lund University Hospital and Lund University (Sweden); Moelne, Johan [Department of Clinical Pathology, Sahlgrenska University Hospital and University of Gothenburg (Sweden); Wallin, Maria [Department of Occupational and Environmental Medicine, Sahlgrenska University Hospital and University of Gothenburg, P.O. Box 414, SE 405 30 Gothenburg (Sweden); Olausson, Michael [Department of Transplantation and Liver Surgery, Sahlgrenska University Hospital and University of Gothenburg (Sweden); Modigh, Cecilia; Sallsten, Gerd [Department of Occupational and Environmental Medicine, Sahlgrenska University Hospital and University of Gothenburg, P.O. Box 414, SE 405 30 Gothenburg (Sweden)

    2010-01-15

    Background: Most current knowledge on kidney concentrations of nephrotoxic metals like cadmium (Cd), mercury (Hg), or lead (Pb) comes from autopsy studies. Assessment of metal concentrations in kidney biopsies from living subjects can be combined with information about exposure sources like smoking, diet, and occupation supplied by the biopsied subjects themselves. Objectives: To determine kidney concentrations of Cd, Hg, and Pb in living kidney donors, and assess associations with common exposure sources and background factors. Methods: Metal concentrations were determined in 109 living kidney donors aged 24-70 years (median 51), using inductively coupled plasma-mass spectrometry (Cd and Pb) and cold vapor atomic fluorescence spectrometry (Hg). Smoking habits, occupation, dental amalgam, fish consumption, and iron stores were evaluated. Results: The median kidney concentrations were 12.9 {mu}g/g (wet weight) for cadmium, 0.21 {mu}g/g for mercury, and 0.08 {mu}g/g for lead. Kidney Cd increased by 3.9 {mu}g/g for a 10 year increase in age, and by 3.7 {mu}g/g for an extra 10 pack-years of smoking. Levels in non-smokers were similar to those found in the 1970s. Low iron stores (low serum ferritin) in women increased kidney Cd by 4.5 {mu}g/g. Kidney Hg increased by 6% for every additional amalgam surface, but was not associated with fish consumption. Lead was unaffected by the background factors surveyed. Conclusions: In Sweden, kidney Cd levels have decreased due to less smoking, while the impact of diet seems unchanged. Dental amalgam is the main determinant of kidney Hg. Kidney Pb levels are very low due to decreased exposure.

  1. Cadmium, mercury, and lead in kidney cortex of living kidney donors: Impact of different exposure sources,

    International Nuclear Information System (INIS)

    Barregard, Lars; Fabricius-Lagging, Elisabeth; Lundh, Thomas; Moelne, Johan; Wallin, Maria; Olausson, Michael; Modigh, Cecilia; Sallsten, Gerd

    2010-01-01

    Background: Most current knowledge on kidney concentrations of nephrotoxic metals like cadmium (Cd), mercury (Hg), or lead (Pb) comes from autopsy studies. Assessment of metal concentrations in kidney biopsies from living subjects can be combined with information about exposure sources like smoking, diet, and occupation supplied by the biopsied subjects themselves. Objectives: To determine kidney concentrations of Cd, Hg, and Pb in living kidney donors, and assess associations with common exposure sources and background factors. Methods: Metal concentrations were determined in 109 living kidney donors aged 24-70 years (median 51), using inductively coupled plasma-mass spectrometry (Cd and Pb) and cold vapor atomic fluorescence spectrometry (Hg). Smoking habits, occupation, dental amalgam, fish consumption, and iron stores were evaluated. Results: The median kidney concentrations were 12.9 μg/g (wet weight) for cadmium, 0.21 μg/g for mercury, and 0.08 μg/g for lead. Kidney Cd increased by 3.9 μg/g for a 10 year increase in age, and by 3.7 μg/g for an extra 10 pack-years of smoking. Levels in non-smokers were similar to those found in the 1970s. Low iron stores (low serum ferritin) in women increased kidney Cd by 4.5 μg/g. Kidney Hg increased by 6% for every additional amalgam surface, but was not associated with fish consumption. Lead was unaffected by the background factors surveyed. Conclusions: In Sweden, kidney Cd levels have decreased due to less smoking, while the impact of diet seems unchanged. Dental amalgam is the main determinant of kidney Hg. Kidney Pb levels are very low due to decreased exposure.

  2. Quantifying the Determinants of Evolutionary Dynamics Leading to Drug Resistance.

    Directory of Open Access Journals (Sweden)

    Guillaume Chevereau

    Full Text Available The emergence of drug resistant pathogens is a serious public health problem. It is a long-standing goal to predict rates of resistance evolution and design optimal treatment strategies accordingly. To this end, it is crucial to reveal the underlying causes of drug-specific differences in the evolutionary dynamics leading to resistance. However, it remains largely unknown why the rates of resistance evolution via spontaneous mutations and the diversity of mutational paths vary substantially between drugs. Here we comprehensively quantify the distribution of fitness effects (DFE of mutations, a key determinant of evolutionary dynamics, in the presence of eight antibiotics representing the main modes of action. Using precise high-throughput fitness measurements for genome-wide Escherichia coli gene deletion strains, we find that the width of the DFE varies dramatically between antibiotics and, contrary to conventional wisdom, for some drugs the DFE width is lower than in the absence of stress. We show that this previously underappreciated divergence in DFE width among antibiotics is largely caused by their distinct drug-specific dose-response characteristics. Unlike the DFE, the magnitude of the changes in tolerated drug concentration resulting from genome-wide mutations is similar for most drugs but exceptionally small for the antibiotic nitrofurantoin, i.e., mutations generally have considerably smaller resistance effects for nitrofurantoin than for other drugs. A population genetics model predicts that resistance evolution for drugs with this property is severely limited and confined to reproducible mutational paths. We tested this prediction in laboratory evolution experiments using the "morbidostat", a device for evolving bacteria in well-controlled drug environments. Nitrofurantoin resistance indeed evolved extremely slowly via reproducible mutations-an almost paradoxical behavior since this drug causes DNA damage and increases the mutation

  3. Drinking water: a major source of lead exposure in Karachi, Pakistan.

    Science.gov (United States)

    Ul-Haq, N; Arain, M A; Badar, N; Rasheed, M; Haque, Z

    2011-11-01

    Excess lead in drinking water is a neglected source of lead toxicity in Pakistan. A cross-sectional survey in 2007/08 was made of water samples from drinking water sources in Karachi, a large industrial city. This study aimed to compare lead levels between untreated ground water and treated surface (tap) water in 18 different districts. Of 216 ground and surface water samples collected, 86% had lead levels higher than the World Health Organization maximum acceptable concentration of l0 ppb. Mean lead concentration in ground water [146 (SD 119) ppb] was significantly higher than in surface water [77.1 (SD 54) ppb]. None of the 18 districts had a mean lead level of ground or surface water below the WHO cut-off and ground water sources in 9 districts had a severe level of contamination (>150 ppb). Urgent action is needed to eliminate sources of contamination.

  4. information source accessibility and usage as determinants

    African Journals Online (AJOL)

    UDS-CAPTURED

    1990-04-28

    Apr 28, 1990 ... accessibility and business performance of the community banks over a six-year period. The ... relationship with the banks' business performance. ..... Marketing Management ... Effects of the Information on the Business Performance of Banks. ..... 'Information sources used for strategic planning decisions.

  5. Tracing the anthropogenic lead sources in coastal sediments of SE-Pacific (36 deg. Lat. S) using stable lead isotopes

    International Nuclear Information System (INIS)

    Munoz, Praxedes N.V.; Garbe-Schoenberg, Carl-Dieter; Salamanca, Marco A.

    2004-01-01

    This study evaluates the main sources of antropogenic Pb in one of the most industrialized centers of the southern Chilean coast (36 deg. S). Stable lead isotopes ( 206 Pb/ 207 Pb, 208 Pb/ 207 Pb) were used to trace main Pb sources to coastal sediments, considering the suspended particulate matter (SPM) from marine (traps), continental (rivers) and industrial effluents, sediments and leaded gasoline samples. The atmospheric input was evaluated through natural collectors; i.e. Raqui-Tubul salt marsh. Results show that marine samples lie on a trend between industrial effluents (∼1.16, 2.44) and natural sources (1.20, 2.50), not related to gasoline consumption. Salt marsh sediments show comparable isotopic composition to marine samples, suggesting the importance of the atmospheric input in the coastal sediments, not related to the leaded gasoline composition either. The continental input (1.18, 2.48) is highly influenced by precipitation, being difficult to separate both sources (atmosphere and continental runoff), showing also similar isotopic ratio to marine sediments. The signal of industrial emissions is masked with the introduction of Pb with higher isotopic ratios, compared to the values observed in the material collected from traps (SPM ∼1.19, 2.48). The contribution of more radiogenic Pb by the upwelling is suggested

  6. Determination of lead in human calculi and its effects on renal function of lead occupational workers

    International Nuclear Information System (INIS)

    Memon, F.; Vasandani, A.G.M.

    2016-01-01

    Seventy five samples of renal and eighteen samples of supra gingival calculi of lead recycling workers were collected over the period of seven years (2008-2014) and studied for the accumulation of lead. The results were compared with those of non exposed subjects. The lead content of calculi was investigated for its dependence on type and composition of calculi, blood lead, job status and duration of exposure. The effect of blood lead and renal calculi was also investigated in relation to kidney function of respective subjects. The mean lead levels of various types of calculi were found to follow the order as phosphate > oxalate > urate > cystine while single principal group of supra gingival calculi resulted in lower levels of metal. The lead content of calculi positively correlated with phosphate content of both of the renal (r = 0.655) and supra gingival calculi (r= 0.866). Impaired renal function was more pronounced in active workers and depended on blood lead levels in addition to presence of metal in renal calculi. (author)

  7. Levels and source apportionment of children's lead exposure: Could urinary lead be used to identify the levels and sources of children's lead pollution?

    International Nuclear Information System (INIS)

    Cao, Suzhen; Duan, Xiaoli; Zhao, Xiuge; Wang, Beibei; Ma, Jin; Fan, Delong; Sun, Chengye; He, Bin; Wei, Fusheng; Jiang, Guibin

    2015-01-01

    As a highly toxic heavy metal, the pollution and exposure risks of lead are of widespread concern for human health. However, the collection of blood samples for use as an indicator of lead pollution is not always feasible in most cohort or longitudinal studies, especially those involving children health. To evaluate the potential use of urinary lead as an indicator of exposure levels and source apportionment, accompanying with environmental media samples, lead concentrations and isotopic measurements (expressed as 207 Pb/ 206 Pb, 208 Pb/ 206 Pb and 204 Pb/ 206 Pb) were investigated and compared between blood and urine from children living in the vicinities of a typical coking plant and lead-acid battery factory. The results showed urinary lead might not be a preferable proxy for estimating blood lead levels. Fortunately, urinary lead isotopic measurements could be used as an alternative for identifying the sources of children's lead exposure, which coincided well with the blood lead isotope ratio analysis. - Highlights: • Pb isotopes of environmental media and children's blood and urine were analyzed. • Pb exposure and pollution source were studied in lead-acid battery and coking areas. • Pb isotope ratios in blood and urine were similar to those of food, water and PM. • Urine Pb level may not be used as a proxy for indicating the lead levels in blood. • Urine Pb isotope ratios is an alternative to identify source and exposure pathways. - Urinary lead is not a preferable proxy to estimate blood lead level, but urinary lead isotope ratios could be an alternative for identifying the sources of lead exposure in children

  8. determination of lead at nanogram level in water samples

    African Journals Online (AJOL)

    Preferred Customer

    Environmental Pollution Control Technology of Henan Province,. Henan Normal ... storage battery, drainage from lead ore mines, paints, munitions, and petroleum refining. Many .... Therefore, this sequence was adopted in subsequent experiments. .... fluorescence spectrometer by using inexpensive and safe reagents.

  9. Sources of variability in collection and preparation of paint and lead-coating samples.

    Science.gov (United States)

    Harper, S L; Gutknecht, W F

    2001-06-01

    Chronic exposure of children to lead (Pb) can result in permanent physiological impairment. Since surfaces coated with lead-containing paints and varnishes are potential sources of exposure, it is extremely important that reliable methods for sampling and analysis be available. The sources of variability in the collection and preparation of samples were investigated to improve the performance and comparability of methods and to ensure that data generated will be adequate for its intended use. Paint samples of varying sizes (areas and masses) were collected at different locations across a variety of surfaces including metal, plaster, concrete, and wood. A variety of grinding techniques were compared. Manual mortar and pestle grinding for at least 1.5 min and mechanized grinding techniques were found to generate similar homogenous particle size distributions required for aliquots as small as 0.10 g. When 342 samples were evaluated for sample weight loss during mortar and pestle grinding, 4% had 20% or greater loss with a high of 41%. Homogenization and sub-sampling steps were found to be the principal sources of variability related to the size of the sample collected. Analysis of samples from different locations on apparently identical surfaces were found to vary by more than a factor of two both in Pb concentration (mg cm-2 or %) and areal coating density (g cm-2). Analyses of substrates were performed to determine the Pb remaining after coating removal. Levels as high as 1% Pb were found in some substrate samples, corresponding to more than 35 mg cm-2 Pb. In conclusion, these sources of variability must be considered in development and/or application of any sampling and analysis methodologies.

  10. Lead exposure in indigenous children of the Peruvian Amazon : seeking the hidden source,venturing into participatory research

    OpenAIRE

    Anticona Huaynate, Cynthia

    2012-01-01

    Introduction. In 2006, a Peruvian environmental agency reported the presence of elevated blood lead levels (BLLs) in indigenous communities of the Corrientes river basin. This is a territory in the Peruvian Amazon where oil activity has been associated with serious environmental effects, with impact on an ongoing social conflict. This PhD project aimed to determine the lead sources, risk factors and pathways in children of these communities and to suggest control and prevention strategies. Gi...

  11. Summit Petroleum Corporation Single Source Determination

    Science.gov (United States)

    This document may be of assistance in applying the New Source Review (NSR) air permitting regulations including the Prevention of Significant Deterioration (PSD) requirements. This document is part of the NSR Policy and Guidance Database. Some documents in the database are a scanned or retyped version of a paper photocopy of the original. Although we have taken considerable effort to quality assure the documents, some may contain typographical errors. Contact the office that issued the document if you need a copy of the original.

  12. Single Source Determination for General Dynamics

    Science.gov (United States)

    This document may be of assistance in applying the New Source Review (NSR) air permitting regulations including the Prevention of Significant Deterioration (PSD) requirements. This document is part of the NSR Policy and Guidance Database. Some documents in the database are a scanned or retyped version of a paper photocopy of the original. Although we have taken considerable effort to quality assure the documents, some may contain typographical errors. Contact the office that issued the document if you need a copy of the original.

  13. Next-To-Leading Order Determination of Fragmentation Functions

    CERN Document Server

    Bourhis, L; Guillet, J P; Werlen, M

    2001-01-01

    We analyse LEP and PETRA data on single inclusive charged hadron cross-sections to establish new sets of Next-to-Leading order Fragmentation Functions. Data on hadro-production of large-$p_{\\bot}$ hadrons are also used to constrain the gluon Fragmentation Function. We carry out a critical comparison with other NLO parametrizations.

  14. Determination of lead and cadmium in biological materials

    International Nuclear Information System (INIS)

    Stoeppler, M.; Backhaus, F.; Dahl, R.; Hagedorn-Goetz, H.; Hilpert, K.; Klahre, P.; Rutzel, H.; Valenta, P.; Nuernberg, H.W.; Dumont, M.

    1975-01-01

    Sampling techniques and experience, and decomposition methods are presented. The processes used in flameless atomic absorption spectrometry (including the method using automatic insertion of samples), pulse polarography and isotope dilution mass spectrometry are described. Finally, the results of lead and cadmium measurements in bovine liver, blood, urine and hair samples are reported and discussed with a comparison of methods in some cases

  15. Derivative spectrophotometric determination of trace lead in alloys ...

    African Journals Online (AJOL)

    diethylaminophenol-ammonium tetraphenylborate with microcrystalline naphthalene or by a column method in the pH range 4.0–6.0 from a large volume of aqueous solutions of various samples. After filtration, the solid mass consisting of the lead complex and ...

  16. Determination of Crack Area on Lead Apron used in Diagnostic Radiology

    International Nuclear Information System (INIS)

    Norriza Mohd Isa; Muhammad Jamal Muhammad Isa; Asmaliza Hashim

    2014-01-01

    The study was performed to determine crack area of lead aprons used by personnel as radiation protector from unnecessary radiation in diagnostic radiology. The experiment was done using general X-ray and Computed Radiography (CR) systems. Calibration curve was plotted for beam quality at 80 kVp and source to detector distance (SDD) is 100 cm by selecting manual exposure mode. Lead sheet with thickness from 0.1 to 1.0 mm were used for this purpose. It was used to relate the pixel value of lead sheet images with their thickness. A few sample of lead aprons with different thickness from a hospital and our laboratories were obtained and then undergoing the inspection at our laboratory through this procedure. The samples were divided with two groups based on how long they were used which are less 10 years and more than 10 years. The images data of the sample were obtained and analysis using our developed software. The reference object with known its area was also used in the experiment to ensure our output using the software is reliable and acceptable. The results shown that lead aprons used more than 10 years have depicted more crack areas compare with the lead apron used less than 10 years. (author)

  17. Effect of the lead screen in the radiographic image using iridium 192 as a source

    International Nuclear Information System (INIS)

    Garate Rojas, M.

    1983-01-01

    It's presented the effect of the lead screen in the image obtained on an impressionable film used in industrial gammagraphy. The source used was Iridium 192 and the tests were simulated like a real inspection. (E.G.) [pt

  18. Monitoring light source for CMS lead tungstate crystal calorimeter at LHC

    CERN Document Server

    Zhang Li Yuan; Zhu Ren Yuan; Liu Dun Can

    2000-01-01

    Light monitoring will serve as an inter calibration for CMS lead tungstate crystals in situ at LHC, which is crucial for maintaining crystal calorimeter's sub percent constant term in the energy resolution. This paper presents the design of the CMS ECAL monitoring light source and high level distribution system. The correlations between variations of the light output and the transmittance for the CMS choice of Y doped PbWO//4 crystals were investigated, and were used to study monitoring linearity and sensitivity as a function of the wavelength. The monitoring wavelength was determined so that a good linearity as well as adequate sensitivity can be achieved. The performance of a custom manufactured tunable laser system is presented. Issues related to monitoring precision are discussed. 29 Refs.

  19. Monitoring light source for CMS lead tungstate crystal calorimeter at LHC

    CERN Document Server

    Zhang Liang Ying; Zhu, R Y; Liu, D T

    2001-01-01

    Light monitoring will serve as an intercalibration for Compact Muon Solenoid (CMS) lead tungstate crystals in situ at the Large Hadronic Collider, which is crucial for maintaining crystal calorimeter's subpercent constant term in the energy resolution. This paper presents the design of the CMS electromagnetic calorimeter monitoring light source and high-level distribution system. The correlations between variations of the light output and the transmittance for the CMS choice of yttrium-doped PbWO/sub 4/ crystals were investigated and were used to study monitoring linearity and sensitivity as a function of wavelength. The monitoring wavelength was determined so that a good linearity as well as adequate sensitivity can be achieved. The performance of a custom manufactured tunable laser system is presented. Issues related to monitoring precision are discussed. (12 refs).

  20. Positive matrix factorization as source apportionment of soil lead and cadmium around a battery plant (Changxing County, China).

    Science.gov (United States)

    Xue, Jian-long; Zhi, Yu-you; Yang, Li-ping; Shi, Jia-chun; Zeng, Ling-zao; Wu, Lao-sheng

    2014-06-01

    Chemical compositions of soil samples are multivariate in nature and provide datasets suitable for the application of multivariate factor analytical techniques. One of the analytical techniques, the positive matrix factorization (PMF), uses a weighted least square by fitting the data matrix to determine the weights of the sources based on the error estimates of each data point. In this research, PMF was employed to apportion the sources of heavy metals in 104 soil samples taken within a 1-km radius of a lead battery plant contaminated site in Changxing County, Zhejiang Province, China. The site is heavily contaminated with high concentrations of lead (Pb) and cadmium (Cd). PMF successfully partitioned the variances into sources related to soil background, agronomic practices, and the lead battery plants combined with a geostatistical approach. It was estimated that the lead battery plants and the agronomic practices contributed 55.37 and 29.28%, respectively, for soil Pb of the total source. Soil Cd mainly came from the lead battery plants (65.92%), followed by the agronomic practices (21.65%), and soil parent materials (12.43%). This research indicates that PMF combined with geostatistics is a useful tool for source identification and apportionment.

  1. E-Waste Informal Recycling: An Emerging Source of Lead Exposure in South America.

    Science.gov (United States)

    Pascale, Antonio; Sosa, Adriana; Bares, Cristina; Battocletti, Alejandra; Moll, María José; Pose, Darío; Laborde, Amalia; González, Hugo; Feola, Gabriella

    2016-01-01

    Primitive electronic waste (e-waste) recycling creates exposures to several hazardous substances including lead. In Uruguay, primitive recycling procedures are a significant source of lead exposure. The aim of this study was to examine lead exposure in blood lead levels (BLLs) in low-income children exposed to lead through burning cables. A sample of children and adolescents exposed to lead through burning cable activities were assessed at the Department of Toxicology in Montevideo, Uruguay, between 2010 and 2014. Soil lead levels of residences were taken shortly after their assessment. The final sample included 69 children and adolescents (mean age 7.89 years). More than 66% of participants had an additional source of lead exposure-manual gathering of metals-and based paint (r = 0.23; P source of lead exposure was the manual gathering of metals. The average BLL among children and adolescents in this study is higher than the BLLs currently suggested in medical intervention. Future research should focus on exploring effective interventions to reduce lead exposure among this vulnerable group. Copyright © 2016 The Authors. Published by Elsevier Inc. All rights reserved.

  2. Experimental apparatus to determine lead attenuation coefficients for photons of 0.511 MeV

    International Nuclear Information System (INIS)

    Vargas, Luis C.B.; Cardoso, Domingos O.; Gavazza, Sérgio; Morales, Rudnei K.; Oliveira, Luciano S. R.

    2017-01-01

    Radioactive gamma-emitting sources with higher energies than 1.022 MeV, may interact with matter by pair production process, generating two photons of 0.511 MeV in the positron annihilation, that may contribute to increase doses in both IOE´s or public. National regulatory agencies require a radiation protection plan and a shielding project to consider the influence of these photons in the licensing procedure. This work will present all steps for the development of the experimental apparatus for determination of the attenuation coefficients for photons with energy of 0.511 MeV in lead. (author)

  3. Urban Airborne Lead: X-Ray Absorption Spectroscopy Establishes Soil as Dominant Source

    OpenAIRE

    Pingitore, Nicholas E.; Clague, Juan W.; Amaya, Maria A.; Maciejewska, Beata; Reynoso, Jes?s J.

    2009-01-01

    BACKGROUND: Despite the dramatic decrease in airborne lead over the past three decades, there are calls for regulatory limits on this potent pediatric neurotoxin lower even than the new (2008) US Environmental Protection Agency standard. To achieve further decreases in airborne lead, what sources would need to be decreased and what costs would ensue? Our aim was to identify and, if possible, quantify the major species (compounds) of lead in recent ambient airborne particulate matter collected...

  4. Determination of contaminators in high purity lead oxide

    International Nuclear Information System (INIS)

    Bellavigna, H.J.; Farias de Funes, S.; Garavaglia, R.N.

    1990-01-01

    Litharge (PbO) is one of the raw materials used in glass fabrication for shielding and cathodic ray tubes employed in measurement instruments; some elements such as silver, chromium, arsenic, bismuth, etc. may confer to the mentioned glasses different unwanted tones which cause image distortion. Emission spectroscopy with photographic detection gives a quick, effective and economical alternative to determine these impurities. (Author) [es

  5. Apparatus for radiation source depth determination in a material

    International Nuclear Information System (INIS)

    Campbell, P.J.

    1979-01-01

    An apparatus is disclosed for determining the depth of a radiation source within a body of material utilizing a radiation source holder moving the radiation source within the body. A plurality of switches have contacts that are fixed in relation to the movement of the radiation source within the material. Trigger means activates a particular switch at a preselected depth of the radiation source. Means for indicating the activation of a switch would thus produce a signal as a representative of the depth of the radiation source

  6. Determination of skin dose reduction by lead equivalent gloves

    International Nuclear Information System (INIS)

    Norriza Mohd Isa; Abd Aziz Mhd Ramli

    2006-01-01

    Radiation protective gloves are always used in medical facilities to protect radiation workers from unnecessary radiation exposure. A study on radiation protection gloves which are produced by local company had been performed by the Medical Physics Group, MINT. The gloves were made of lead equivalent material, as the attenuating element. The gloves were evaluated in term of the percentage of skin dose reduction by using a newly developed procedure and facilities in MINT. Attenuation measurements of the gloves had been carried out using direct beams and scattered radiations of different qualities. TLD rings were fitted on finger phantom; and water phantom were used in the measurement. The result were obtained and analysed based on data supplied by manufacturer. (Author)

  7. Determinants of blood-lead levels in children in Callao and Lima metropolitan area

    Directory of Open Access Journals (Sweden)

    Espinoza Rocío

    2003-01-01

    Full Text Available OBJECTIVES: To determine blood lead levels in urban populations of children (n=2 510 and women (n=874 in the early postpartum in certain districts of Lima and Callao, and to correlate those levels with particular exposures. MATERIAL AND METHODS: Between July 1998 and January 1999 cross sectional study was conducted. The study population was selected using three sampling strategies in the government operated school system and from public pediatric and maternity hospitals at Lima and Callao, Peru. Study personnel were trained to collect finger stick blood samples with a protocol that minimizes external lead contamination. Lead determinations in blood and environmental samples were performed at the study site using portable anodic striping voltamenters. To determine the simultaneous effects of different predictors on blood lead levels, multivariate regression models were used to estimate adjusted mean differences. RESULTS: The mean blood lead level in the children studied was 9.9 µg/dl ranging from I µg/dl to 64 µg/dl with 29% of the children displaying values greater than 10 µg/dl and 9.4% at levels greater than 20 µg/dl. Among the women, the mean was 3.5 µg/dl (SD=2.4 µg/dl, and 2.4% (n=21 displayed levels greater than 10 µg/dl. Important differences were observed between the sample locations, and the highest levels were documented in the port region near Callao. The mean level of blood lead in this group was 25.6 µg/dl (SD=4.6 µg/dl, while among the rest of the sample it was 7.1 µg/dl (SD=5.1 µg/dl. The presence of a mineral storage area signified a difference in exposure in excess of 13 µg/dl for children living near the port area in contrast to the other children who were not as close to such fixed sources of lead exposure. For the participants in Lima, the risk of showing levels above 10 µg/dl was associated with exposure to high vehicular traffic. CONCLUSIONS: In metropolitan Lima, we conclude that the mean blood lead levels of

  8. Tracing lead pollution sources in abandoned mine areas using stable Pb isotope ratios.

    Science.gov (United States)

    Yoo, Eun-Jin; Lee, Jung-A; Park, Jae-Seon; Lee, Khanghyun; Lee, Won-Seok; Han, Jin-Seok; Choi, Jong-Woo

    2014-02-01

    This study focused on Pb isotope ratios of sediments in areas around an abandoned mine to determine if the ratios can be used as a source tracer. For pretreatment, sediment samples were dissolved with mixed acids, and a multi-collector inductively coupled plasma mass spectrometer (MC-ICP-MS, Nu plasma II) was used to investigate the Pb isotopic composition of the samples. The measured isotope ratios were then corrected for instrumental mass fractionation by measuring the (203)Tl/(205)Tl ratio. Repeated measurements with the NIST SRM 981 reference material showed that the precision of all ratios was below 104 ppm (±2σ) for 50 ng/g. The isotope ratios ((207)Pb/(206)Pb) found were 0.85073 ± 0.0004~0.85373 ± 0.0003 for the main stream, while they were 0.83736 ± 0.0010 for the tributary and 0.84393 ± 0.0002 for the confluence. A binary mixing equation for isotope ratios showed that the contributions of mine lead to neighboring areas were up to 60%. Therefore, Pb isotope ratios can be a good source tracer for areas around abandoned mines.

  9. Urban airborne lead: X-ray absorption spectroscopy establishes soil as dominant source.

    Directory of Open Access Journals (Sweden)

    Nicholas E Pingitore

    Full Text Available BACKGROUND: Despite the dramatic decrease in airborne lead over the past three decades, there are calls for regulatory limits on this potent pediatric neurotoxin lower even than the new (2008 US Environmental Protection Agency standard. To achieve further decreases in airborne lead, what sources would need to be decreased and what costs would ensue? Our aim was to identify and, if possible, quantify the major species (compounds of lead in recent ambient airborne particulate matter collected in El Paso, TX, USA. METHODOLOGY/PRINCIPAL FINDINGS: We used synchrotron-based XAFS (x-ray absorption fine structure to identify and quantify the major Pb species. XAFS provides molecular-level structural information about a specific element in a bulk sample. Pb-humate is the dominant form of lead in contemporary El Paso air. Pb-humate is a stable, sorbed complex produced exclusively in the humus fraction of Pb-contaminated soils; it also is the major lead species in El Paso soils. Thus such soil must be the dominant source, and its resuspension into the air, the transfer process, providing lead particles to the local air. CONCLUSIONS/SIGNIFICANCE: Current industrial and commercial activity apparently is not a major source of airborne lead in El Paso, and presumably other locales that have eliminated such traditional sources as leaded gasoline. Instead, local contaminated soil, legacy of earlier anthropogenic Pb releases, serves as a long-term reservoir that gradually leaks particulate lead to the atmosphere. Given the difficulty and expense of large-scale soil remediation or removal, fugitive soil likely constrains a lower limit for airborne lead levels in many urban settings.

  10. Urban airborne lead: X-ray absorption spectroscopy establishes soil as dominant source.

    Science.gov (United States)

    Pingitore, Nicholas E; Clague, Juan W; Amaya, Maria A; Maciejewska, Beata; Reynoso, Jesús J

    2009-01-01

    Despite the dramatic decrease in airborne lead over the past three decades, there are calls for regulatory limits on this potent pediatric neurotoxin lower even than the new (2008) US Environmental Protection Agency standard. To achieve further decreases in airborne lead, what sources would need to be decreased and what costs would ensue? Our aim was to identify and, if possible, quantify the major species (compounds) of lead in recent ambient airborne particulate matter collected in El Paso, TX, USA. We used synchrotron-based XAFS (x-ray absorption fine structure) to identify and quantify the major Pb species. XAFS provides molecular-level structural information about a specific element in a bulk sample. Pb-humate is the dominant form of lead in contemporary El Paso air. Pb-humate is a stable, sorbed complex produced exclusively in the humus fraction of Pb-contaminated soils; it also is the major lead species in El Paso soils. Thus such soil must be the dominant source, and its resuspension into the air, the transfer process, providing lead particles to the local air. Current industrial and commercial activity apparently is not a major source of airborne lead in El Paso, and presumably other locales that have eliminated such traditional sources as leaded gasoline. Instead, local contaminated soil, legacy of earlier anthropogenic Pb releases, serves as a long-term reservoir that gradually leaks particulate lead to the atmosphere. Given the difficulty and expense of large-scale soil remediation or removal, fugitive soil likely constrains a lower limit for airborne lead levels in many urban settings.

  11. Radiometric on-line-determination of lead in lead-zinc ore processing

    International Nuclear Information System (INIS)

    Lubecki, A.; Wiese, K.; Gralher, M.

    1983-01-01

    By the example of Pb determination in PbS-ZnS flotation liquids the advancement of the radionuclide (Co-57) excited X-ray fluorescence assay technique Graf is reported. The technique of measurement, previously tested in analyzing baryte contained in the fluorsphar flotation liquid was adapted to the conditions prevailing in the PbS-ZnS flotation liquid by modification of theory, principle of measurement, and measuring technique. Testing on an industrial scale was performed in the flotation facility of Preussag AG Metall at Bad Grund, more particularly in the process streams of strategic importance such as ''total tailings'', ''Pb tailings'', and ''lotation feed''. Correspondence between the on-line analytical values and the comparable values from conventional operating analysis was fair. For 31 reference samples from ''total tailings'' and for 20 reference samples from ''Pb tailings'' the mean scattering was calculated to be approx. 0,04%, for 20 reference samples from ''flotation feed'' it amounted to 0,14% Pb. (orig./HP) [de

  12. Lead pollution and its sources along the Turkish coast of the Black Sea

    Directory of Open Access Journals (Sweden)

    M. UNSAL

    2001-12-01

    Full Text Available Lead pollution and its sources have been investigated in the south-eastern and south-western Black Sea. Surficial sediments and mussels were collected in different seasons of the year from the south-eastern and south-western Black Sea and analysed for their lead contents. In the south-eastern Black Sea sediments from the easternmost and from the central stations contained the highest lead concentrations. Sediments contained 8 to 10 times the lead concentrations of sediments from the south-west. Samples taken from rivers, streams and effluents had especially high lead concentrations. The highest lead concentrations were found in sediments collected in October and December. Lead concentrations in mussels from the south-eastern coast were comparatively lower compared to those from the south-western coast. The highest average values occurred in December and in October. In the south-western Black Sea, the highest lead concentrations in sediments were obtained in those from Inebolu, followed by those from around Zonguldak. The concentrations increased from the middle to the west of the southern Black Sea coast, possibly due to the effect of the Danube River. Sediments taken in September had the highest lead concentrations, followed by samples taken in December. Very high lead concentrations (> 10 μ g g-1 were observed in mussels from those stations where the sediments also contained high concentrations. Mussels had their highest lead concentrations in January and April.

  13. Lead Contamination and Source Characterization in Soils Around a Lead-Zinc Smelting Plant in a Near-Urban Environment in Baoji, China.

    Science.gov (United States)

    Deng, Wenbo; Li, Xuxiang; An, Zhisheng; Yang, Liu

    2016-11-01

    Economic reforms in China since 1978 have promoted nationwide socioeconomic advancement but led to a considerable amount of environmental pollution. The distribution and sources of Pb in a typical peri-urban industrial part of Baoji, China, were assessed by determining the Pb contents and isotopic compositions in 52 topsoil samples from the study area. The topsoil samples were polluted averagely with 40.88 mg Pb kg -1 , was 1.86 times higher than the Pb content of local background soil (22.04 mg kg -1 ). Pb isotopic compositions were determined by analyzing samples prepared using total digestion and acid extraction methods. Radiogenic isotopes contributed more to the Pb concentrations in the acid extracts than in the total digests. This was shown by the 207/206 Pb and 208/206 Pb ratios, which were 0.845-0.88 and 2.088-2.128, respectively, in the acid extracts and 0.841-0.875 and 2.086-2.125, respectively, in the total digests. This indicates that anthropogenic sources of Pb could be identified more sensitively in acid extracts than in total digests. The Pb isotope ratios showed that burning coal and smelting ore are the predominant anthropogenic sources of Pb in the study area, i.e., a lead-zinc smelter and a coking plant are major sources of Pb in the study area.

  14. Alluvial and riparian soils as major sources of lead exposure in young children in the Philippines: the role of floods.

    Science.gov (United States)

    Ostrea, Enrique M; Ostrea, Angelo M; Villanueva-Uy, Ma Esterlita; Chiodo, Lisa; Janisse, James

    2015-04-01

    The objective of this paper was to determine the prevalence and sources of high lead (Pb) exposure among children in Bulacan, Philippines. A total of 150 children (6-7 years old) and their caregivers were studied. Lead was analyzed in children hair and deciduous teeth. Sources of lead exposure were determined by caregiver interview and Pb analysis of house soil, drinking faucet water, air, and water from seven Bulacan rivers. Lead was positive in 91.3% of children's hair (MC or median concentration = 8.9 μg/g; range = 0-38.29), in 46.2% of the teeth (MC = 0.000 μg/mg in positive samples; range = 0.00-0.020), in 100% of soil (MC = 27.06 mg/kg; range = 3.05-1155.80), in 21.1% of air (MC = 0 μg/Ncm; range = 0-0.10), in 4% of house, faucet water (MC = 0.0 ppm; range = 0-40). There was a significant correlation (Spearman's rho) between Pb in children's hair and soil (r = 0.195; p = 0.017) and between Pb in house water and outdoor air (r = 0.616; p = 0.005). There is no significant correlation between Pb in children's hair and teeth. None of the potential sources of Pb from interview were related to lead exposure in the children. Water from seven Bulacan rivers was 100% positive for lead (MC = 70.00 ppb; range = 30-90). Widespread flooding with river overflow occurred in Bulacan in 2009 which likely caused lead contamination of the soil. There was no significant difference in the lead concentration of the soil whether near or far from the river (p = 0.205, Mann-Whitney U test). High lead exposure in children in Bulacan is likely from soil contaminated by lead-polluted rivers during flooding. In areas where flooding is common, alluvial and riparian soils from polluted rivers are important sources of lead exposure in children.

  15. Measurements of total lead concentrations and of lead isotope ratios in whole blood by use of inductively coupled plasma source mass spectrometry

    International Nuclear Information System (INIS)

    Delves, H.T.; Campbell, M.J.

    1988-01-01

    Methods are described for the accurate and precise determination of total lead and its isotopic composition in whole blood using inductively coupled plasma source mass spectrometry (ICP-MS). Sensitivities of up to 3 x 10 6 counts s -1 for 208 Pb at a total lead concentration of 5 μmol l -1 (1 μg ml -1 ) enabled total blood lead levels to be measured in 4 min per sample, with a detection limit of 0.072 μmol l -1 (15 μg l -1 ). The agreement between ICP-MS and atomic absorption spectrometry (AAS) for this analysis was excellent: ICP-MS 0.996 x AAS -0.0165 μmol l -1 ; r 0.994. Isotope ratio measurements required 15 min to achieve the required accuracy and precision both of which were generally better than 0.5% for 206 Pb: 207 Pb and 208 Pb: 206 Pb isotopic lead ratios. The ICP-MS data for these ratios in ten quality control blood specimens has a mean bias relative to isotope dilution mass spectrometry of -0.412% for 206 Pb: 207 Pb ratios and of +0.055% for the 208 Pb: 206 Pb ratios. This level of accuracy and that of the total blood lead measurements is sufficient to permit application of these ICP-MS methods to environmental studies. (author)

  16. Occurrence and determinants of increases in blood lead levels in children shortly after lead hazard control activities

    International Nuclear Information System (INIS)

    Clark, Scott; Grote, JoAnn; Wilson, Jonathan; Succop, Paul; Chen Mei; Galke, Warren; McLaine, Pat

    2004-01-01

    This study is an examination of the effect of lead hazard control strategies on children's blood lead levels immediately after an intervention was conducted as part of the US Department of Housing and Urban Development's Lead-Based Paint Hazard Control Grant Program. Fourteen state and local government grantees participated in the evaluation. The findings indicated an overall average reduction in the blood lead levels of 869 children soon after the implementation of lead hazard controls. However, 9.3% of these children (n=81) had blood lead increases of 5 μg/dL or more. Data routinely collected as part of the evaluation, as well as additional information supplied by the individual programs, were used to determine potential reasons for these observed increases in blood lead. A logistic regression analysis indicated that three principal factors were associated with the blood lead increases: the number of exterior deteriorations present in the child's home (prior to intervention), the educational level of the female parent or guardian of the child, and the child's age. The statistical analysis did not find evidence that children living in households that either did not relocate or relocated for less than the full work period were significantly more likely to have a blood lead increase equal to or greater than 5 μg/dL than children living in households that fully relocated. Statistical analyses also did not reveal any single interior strategy to be more or less likely than others to be associated with a blood lead increase of 5 μg/dL or more

  17. Lead in school children from Morelos, Mexico: levels, sources and feasible interventions.

    Science.gov (United States)

    Farías, Paulina; Álamo-Hernández, Urinda; Mancilla-Sánchez, Leonardo; Texcalac-Sangrador, José Luis; Carrizales-Yáñez, Leticia; Riojas-Rodríguez, Horacio

    2014-12-01

    Lead is a pervasive pollutant, associated at low levels to many adverse health effects. To investigate lead levels, exposure pathways and intervention possibilities in school children from Alpuyeca, in Morelos, Mexico. Blood lead concentrations (BPb) were measured in 226 children in 2011. Exposure pathways were assessed through a questionnaire, lead measurements in different environmental matrices and spatial aggregation analysis of lead concentrations. BPb ranged from 1.5 to 36.5 ìg/dL, with a mean (SD) of 7.23 (4.9) ìg/dL. Sixty-four and 18% of the children had BPb > 5 ìg/dL and > 10 ìg/dL, respectively. The use of lead glazed ceramics was reported in almost half of the households; it was the main BPb determinant and it was associated with an increased risk of having BPb > 5 g/dL by 2.7 times (p = 0.001). Environmental samples were within US EPA’s lead recommended limits, and blood lead levels were randomly distributed in the community. Lead remains a public health problem in Alpuyeca, Mexico. Unlike other local pollutant lead exposure prevention can be achieved inexpensively and in a short term. Interventions should make mothers aware of lead's health effects and empower them to safeguard their children's health by avoiding the culturally ingrained use of lead glazed pottery.

  18. Stable isotopes of lead and strontium as tracers of sources of airborne particulate matter in Kyrgyzstan.

    Science.gov (United States)

    Central Asia is dominated by an arid climate and desert-like conditions, leading to the potential of long-range transport of desert dust. One potential source of dust to Central Asia is the Aral Sea, the surface area of which has receded in size from 68,000 km2 to 14,280 km2, lar...

  19. Determination of spatial continuity of soil lead levels in an urban residential neighborhood

    Energy Technology Data Exchange (ETDEWEB)

    Shinn, N.J.; Bing-Canar, J.; Cailas, M.; Peneff, N.; Binns, H.J.

    2000-01-01

    This study uses geostatistical techniques to model and estimate soil lead levels in an urban, residential neighborhood. Sixty-two composite soil samples in a four-block area of brick and stone homes were obtained. The spatial continuity of soil lead levels was modeled with a semi-variogram, which was then used to estimate lead levels at unsampled locations, a process called kriging. Because soil lead levels were spatially correlated, it is likely that a nonrandom process generated the lead distribution found. This finding signifies the existence of lead sources which were tentatively identified on historical maps of the area and from past traffic volume patterns. The distribution of kriged estimates of soil lead levels provides an explanatory tool for exploring and identifying potential sources and may be useful for targeting urban soil abatement efforts.

  20. Sources and characteristics of lead pollution in the urban environment of Guangzhou

    International Nuclear Information System (INIS)

    Duzgoren-Aydin, Nurdan S.

    2007-01-01

    Guangzhou, the capital of the southeastern province of Guangdong, is one of the largest and most rapidly developing industrial cities in China. In recent years its rapid economic development has brought great prosperity to the Pearl River Delta (PRD) region, but has also given rise to a wide variety of environmental problems. The current level of lead (Pb) contamination (75-926 mg/kg) in the surface environment of Guangzhou remains a major concern, even though the use of leaded petrol in the city was banned in 1997. The Pb isotope ratios ( 206 Pb/ 207 Pb min-max : 1.1612-1.1961 and 208 Pb/ 207 Pb min-max : 2.4495-2.4838) of the urban dusts from unconfined (road dusts and gully sediments) and relatively confined (vehicular tunnel) settings in Guangzhou remains in a relatively narrow range, comparable with those of the regional natural and anthropogenic sources. This study highlights the inherent shortcomings of the Pb isotope fingerprinting technique for provenancing Pb sources, as both the target media (urban dusts) and potential sources have similar and highly radiogenic Pb isotope values. This could not only lead to an overestimation of the effectiveness of phasing-out of leaded petrol, but also an underestimation of the ever-increasing relative contributions from other potential sources of pollution, including coal combustion, industrial emissions of local Pb-ores and non-additive Pb contents of crude oils. Re-suspended Pb-bearing particulates deposited from early vehicular exhaust emission of leaded petrol with distinctly low Pb isotope compositions are still an important source of Pb pollution in the region

  1. Isotopic ratio based source apportionment of children's blood lead around coking plant area.

    Science.gov (United States)

    Cao, Suzhen; Duan, Xiaoli; Zhao, Xiuge; Wang, Beibei; Ma, Jin; Fan, Delong; Sun, Chengye; He, Bin; Wei, Fusheng; Jiang, Guibin

    2014-12-01

    Lead exposure in the environment is a major hazard affecting human health, particularly for children. The blood lead levels in the local children living around the largest coking area in China were measured, and the source of blood lead and the main pathways of lead exposure were investigated based on lead isotopic ratios ((207)Pb/(206)Pb and (208)Pb/(206)Pb) in blood and in a variety of media, including food, airborne particulate matter, soil, dust and drinking water. The children's blood lead level was 5.25 (1.59 to 34.36 as range) μg dL(-1), lower than the threshold in the current criteria of China defined by the US Centers for Disease Control (10 μg dL(-1)). The isotopic ratios in the blood were 2.111±0.018 for (208)Pb/(206)Pb and 0.864±0.005 for (207)Pb/(206)Pb, similar to those of vegetables, wheat, drinking water, airborne particulate matter, but different from those of vehicle emission and soil/dust, suggesting that the formers were the main pathway of lead exposure among the children. The exposure pathway analysis based on the isotopic ratios and the human health risk assessment showed that dietary intake of food and drinking water contributed 93.67% of total exposed lead. The study further indicated that the coal used in the coking plant is the dominant pollution source of lead in children's blood. Copyright © 2014 Elsevier Ltd. All rights reserved.

  2. Identification of historical lead sources in roof dust and recent lake sediments from an industrialized are: Indications from lead isotopes

    International Nuclear Information System (INIS)

    Chenhall, B.E.; Depers, A.M.; Jones, B.G.; Chiaradia, M.

    1997-01-01

    X-ray fluorescence and stable lead (Pb) isotopic analyses have been undertaken on dusts, known from microscopic investigation to contain significant quantities of industrially- and urban-derived particulate matter, present in the roof cavities of houses in the Illawarra region (N.S.W., Australia), with the objective of examining the historic record of Pb pollution. All investigated houses contained in excess of 250 μg g -1 Pb, with dwellings close to a copper smelter, in a large industrial complex including a major steelworks, containing higher (>2500 μg g -1 ) Pb concentrations. The isotopic composition in the dusts, expressed here as 206 Pb/ 204 Pb, is relatively constant at 17.0, irrespective of dwelling age or distance from the industrial complex. Contamination of the dusts by Pb sourced from paint cannot explain the isotopic uniformity of the dust samples. Isotopic modelling indicates that the dusts contain Pb derived from the copper smelter, gasoline-air Pb and a minor contribution from the steelworks. Isotopic calculations, together with records of particulate pollution emission, indicate a link between the Pb in roof dusts and Pb contamination of the near surface lagoonal sediments. Over the last five decades, atmospheric fallout of Pb-bearing particulate matter appears to have been the dominant pathway for addition of Pb to the lagoon and dwellings in the Illawarra region

  3. Strategic Sourcing of R&D: The Determinants of Success

    Science.gov (United States)

    Brook, Jacques W.; Plugge, Albert

    The outsourcing of the R&D function is an emerging practice of corporate firms. In their attempt to reduce the increasing cost of research and technology development, firms are strategically outsourcing the R&D function or repositioning their internal R&D organisation. By doing so, they are able to benefit from other technology sources around the world. So far, there is only limited research on how firms develop their R&D sourcing strategies and how these strategies are implemented. This study aims to identify which determinants contribute to the success of R&D sourcing strategies. The results of our empirical research indicate that a clear vision of how to manage innovation strategically on a corporate level is a determinant of an effective R&D strategy. Moreover, our findings revealed that the R&D sourcing strategy influences a firm's sourcing capabilities. These sourcing capabilities need to be developed to manage the demand as well as the supply of R&D services. The alignment between the demand capabilities and the supply capabilities contributes to the success of R&D sourcing.

  4. Determination of tellurium in lead and lead alloy using flow injection-hydride generation atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Mesko, Marcia F.; Pozebon, Dirce; Flores, Erico M.M.; Dressler, Valderi L.

    2004-01-01

    A method based on flow injection-hydride generation atomic absorption spectrometry (FI-HG AAS) for the determination of trace amount of Te in lead and lead alloy is described. A flow injection system (FI) and related analytical parameters as well as Te determination and interference caused by Pb, Bi and Ag on Te were investigated. The Pb interference could be overcome by using a small sample volume, while the Bi interference could be overcome by thiourea. However, it was not possible to minimise the interference caused by Ag on Te. The optimised conditions for Te determination in the analysed samples were: 6 mol l -1 HCl as sample carrier solution, 0.75% (m/v) sodium tetrahydroborate as Te reductant, 40 μl of sample solution, and 200 ml min -1 Ar flow rate as carrier gas. The limit of quantification (LOQ) was 1.0 μg g -1 Te (using 250 mg of sample in 50 ml final solution), the limit of detection (LOD) was 2.5 μg l -1 and the relative standard deviation (RSD) was 6% for five consecutive measurements of sample solution. The standard addition calibration method was used. Relatively high sample throughput (ca. 45 sample runs can be performed in a working hour), reduced sample manipulation since matrix separation is not necessary, and minor waste generation are the main advantages of the proposed method for Te determination by FI-HG AAS

  5. Multivariate statistical assessment of heavy metal pollution sources of groundwater around a lead and zinc plant

    Directory of Open Access Journals (Sweden)

    Zamani Abbas Ali

    2012-12-01

    Full Text Available Abstract The contamination of groundwater by heavy metal ions around a lead and zinc plant has been studied. As a case study groundwater contamination in Bonab Industrial Estate (Zanjan-Iran for iron, cobalt, nickel, copper, zinc, cadmium and lead content was investigated using differential pulse polarography (DPP. Although, cobalt, copper and zinc were found correspondingly in 47.8%, 100.0%, and 100.0% of the samples, they did not contain these metals above their maximum contaminant levels (MCLs. Cadmium was detected in 65.2% of the samples and 17.4% of them were polluted by this metal. All samples contained detectable levels of lead and iron with 8.7% and 13.0% of the samples higher than their MCLs. Nickel was also found in 78.3% of the samples, out of which 8.7% were polluted. In general, the results revealed the contamination of groundwater sources in the studied zone. The higher health risks are related to lead, nickel, and cadmium ions. Multivariate statistical techniques were applied for interpreting the experimental data and giving a description for the sources. The data analysis showed correlations and similarities between investigated heavy metals and helps to classify these ion groups. Cluster analysis identified five clusters among the studied heavy metals. Cluster 1 consisted of Pb, Cu, and cluster 3 included Cd, Fe; also each of the elements Zn, Co and Ni was located in groups with single member. The same results were obtained by factor analysis. Statistical investigations revealed that anthropogenic factors and notably lead and zinc plant and pedo-geochemical pollution sources are influencing water quality in the studied area.

  6. Multivariate statistical assessment of heavy metal pollution sources of groundwater around a lead and zinc plant.

    Science.gov (United States)

    Zamani, Abbas Ali; Yaftian, Mohammad Reza; Parizanganeh, Abdolhossein

    2012-12-17

    The contamination of groundwater by heavy metal ions around a lead and zinc plant has been studied. As a case study groundwater contamination in Bonab Industrial Estate (Zanjan-Iran) for iron, cobalt, nickel, copper, zinc, cadmium and lead content was investigated using differential pulse polarography (DPP). Although, cobalt, copper and zinc were found correspondingly in 47.8%, 100.0%, and 100.0% of the samples, they did not contain these metals above their maximum contaminant levels (MCLs). Cadmium was detected in 65.2% of the samples and 17.4% of them were polluted by this metal. All samples contained detectable levels of lead and iron with 8.7% and 13.0% of the samples higher than their MCLs. Nickel was also found in 78.3% of the samples, out of which 8.7% were polluted. In general, the results revealed the contamination of groundwater sources in the studied zone. The higher health risks are related to lead, nickel, and cadmium ions. Multivariate statistical techniques were applied for interpreting the experimental data and giving a description for the sources. The data analysis showed correlations and similarities between investigated heavy metals and helps to classify these ion groups. Cluster analysis identified five clusters among the studied heavy metals. Cluster 1 consisted of Pb, Cu, and cluster 3 included Cd, Fe; also each of the elements Zn, Co and Ni was located in groups with single member. The same results were obtained by factor analysis. Statistical investigations revealed that anthropogenic factors and notably lead and zinc plant and pedo-geochemical pollution sources are influencing water quality in the studied area.

  7. Neutron source strength determination for on-line reactivity measurements

    Energy Technology Data Exchange (ETDEWEB)

    Hoogenboom, J.E.; Sluijs, A.R. van der

    1988-01-01

    A method is described to determine the effective neutron source strength in a nuclear reactor, which must be known when calculating the time-varying reactivity from inverse reactor kinetics for a reactor at low power. When for an initially subcritical reactor the reactivity is changed and kept constant after the change, the effective source strength can be determined from a linear regression of reactor power to a function proportional to the emission rate of delayed neutrons, which can be calculated from the reactor power history. In view of the relatively strong noise present in the reactor power signal at low power, a grouping method for the regression is preferred over the least-squares method. Experiments with a reactor simulator with known source strength showed good agreement. Application to actual reactor signals gave consistent and satisfactory results.

  8. Limitations of absolute activity determination of I-125 sources

    Energy Technology Data Exchange (ETDEWEB)

    Pelled, O; German, U; Kol, R; Levinson, S; Weinstein, M; Laichter, Y [Israel Atomic Energy Commission, Beersheba (Israel). Nuclear Research Center-Negev; Alphasy, Z [Ben-Gurion Univ. of the Negev, Beersheba (Israel)

    1996-12-01

    A method for absolute determination of the activity of a I-125 source, based on the counting rate values of the 27 keV photons and the coincidence photon peak is given in the literature. It is based on the principle that if a radionuclide emits two photons in coincidence , a measurement of its disintegration rate in the photopeak and in the sum- peak can determinate it`s absolute activity. When using this method , the system calibration is simplified and parameters such as source geometry or source position relative to the detector have no significant influence. However, when the coincidence rate is very low, the application of this method is limited because of the statistics of the coincidence peak (authors).

  9. Lead contamination in Eugenia dyeriana herbal preparations from different commercial sources in Malaysia.

    Science.gov (United States)

    Ang, H H

    2008-06-01

    The Drug Control Authority (DCA) of Malaysia implemented the phase three registration of traditional medicines on 1 January, 1992. A total of 100 products in various pharmaceutical dosage forms of a herbal preparation, containing Eugenia dyeriana, either single or combined preparations (more than one medicinal plant), were analyzed for the presence of lead contamination, using atomic absorption spectrophotometry. These samples were bought from different commercial sources in the Malaysian market, after performing a simple random sampling. Results showed that 22% of the above products failed to comply with the quality requirement for traditional medicines in Malaysia. Although this study showed that 78% of the products fully complied with the quality requirement for traditional medicines in Malaysia pertaining to lead, however, they cannot be assumed safe from lead contamination because of batch-to-batch inconsistency.

  10. Lead chromate detected as a source of atmospheric Pb and Cr (VI) pollution

    Science.gov (United States)

    Lee, Pyeong-Koo; Yu, Soonyoung; Chang, Hye Jung; Cho, Hye Young; Kang, Min-Ju; Chae, Byung-Gon

    2016-10-01

    Spherical black carbon aggregates were frequently observed in dust dry deposition in Daejeon, Korea. They were tens of micrometers in diameter and presented a mixture of black carbon and several mineral phases. Transmission electron microscopy (TEM) observations with energy-dispersive X-ray spectroscopy (EDS) and selected area diffraction pattern (SADP) analyses confirmed that the aggregates were compact and included significant amounts of lead chromate (PbCrO4). The compositions and morphologies of the nanosized lead chromate particles suggest that they probably originated from traffic paint used in roads and were combined as discrete minerals with black carbon. Based on Pb isotope analysis and air-mass backward trajectories, the dust in Daejeon received a considerable input of anthropogenic pollutants from heavily industrialized Chinese cities, which implies that long-range transported aerosols containing PbCrO4 were a possible source of the lead and hexavalent chromium levels in East Asia. Lead chromate should be considered to be a source of global atmospheric Pb and Cr(VI) pollution, especially given its toxicity.

  11. Lead chromate detected as a source of atmospheric Pb and Cr (VI) pollution.

    Science.gov (United States)

    Lee, Pyeong-Koo; Yu, Soonyoung; Chang, Hye Jung; Cho, Hye Young; Kang, Min-Ju; Chae, Byung-Gon

    2016-10-25

    Spherical black carbon aggregates were frequently observed in dust dry deposition in Daejeon, Korea. They were tens of micrometers in diameter and presented a mixture of black carbon and several mineral phases. Transmission electron microscopy (TEM) observations with energy-dispersive X-ray spectroscopy (EDS) and selected area diffraction pattern (SADP) analyses confirmed that the aggregates were compact and included significant amounts of lead chromate (PbCrO 4 ). The compositions and morphologies of the nanosized lead chromate particles suggest that they probably originated from traffic paint used in roads and were combined as discrete minerals with black carbon. Based on Pb isotope analysis and air-mass backward trajectories, the dust in Daejeon received a considerable input of anthropogenic pollutants from heavily industrialized Chinese cities, which implies that long-range transported aerosols containing PbCrO 4 were a possible source of the lead and hexavalent chromium levels in East Asia. Lead chromate should be considered to be a source of global atmospheric Pb and Cr(VI) pollution, especially given its toxicity.

  12. Determination of Airborne Lead Contamination in Cichorium intybus L. in an Urban Environment

    OpenAIRE

    YAKUPOĞLU, Dilmaç; GÜRAY, Tülin; SARICA, Deniz YURTSEVER; KAYA, Zeki

    2014-01-01

    The major source of environmental lead (Pb) is the combustion of leaded gasoline. After emission as exhaust, lead in the air falls to earth and contaminates soil and plants. Seventeen wild chicory (Cichorium intybus L.) plant samples were collected from each of 2 urban sites in Ankara, one is located at the road side of major intercity road (heavy traffic) and the other one is located in relatively less traffic area that is about 1 km away from the first location. Lead content of chicory plan...

  13. Determining profile of dose distribution for PD-103 brachytherapy source

    International Nuclear Information System (INIS)

    Berkay, Camgoz; Mehmet, N. Kumru; Gultekin, Yegin

    2006-01-01

    Full text: Brachytherapy is a particular radiotherapy for cancer treatments. By destructing cancerous cells using radiation, the treatment proceeded. When alive tissues are subject it is hazardous to study experimental. For brachytherapy sources generally are studied as theoretical using computer simulation. General concept of the treatment is to locate the radioactive source into cancerous area of related tissue. In computer studies Monte Carlo mathematical method that is in principle based on random number generations, is used. Palladium radioisotope is LDR (Low radiation Dose Rate) source. Main radioactive material was coated with titanium cylinder with 3mm length, 0.25 mm radius. There are two parts of Pd-103 in the titanium cylinder. It is impossible to investigate differential effects come from two part as experimental. Because the source dimensions are small compared with measurement distances. So there is only simulation method. In dosimetric studies it is aimed to determine absorbed dose distribution in tissue as radial and angular. In nuclear physics it is obligation to use computer based methods for researchers. Radiation studies have hazards for scientist and people interacted with radiation. When hazard exceed over recommended limits or physical conditions are not suitable (long work time, non economical experiments, inadequate sensitivity of materials etc.) it is unavoidable to simulate works and experiments before practices of scientific methods in life. In medical area, usage of radiation is required computational work for cancer treatments. Some computational studies are routine in clinics and other studies have scientific development purposes. In brachytherapy studies there are significant differences between experimental measurements and theoretical (computer based) output data. Errors of data taken from experimental studies are larger than simulation values errors. In design of a new brachytherapy source it is important to consider detailed

  14. Environmental determinants of different blood lead levels in children: a quantile analysis from a nationwide survey.

    Science.gov (United States)

    Etchevers, Anne; Le Tertre, Alain; Lucas, Jean-Paul; Bretin, Philippe; Oulhote, Youssef; Le Bot, Barbara; Glorennec, Philippe

    2015-01-01

    Blood lead levels (BLLs) have substantially decreased in recent decades in children in France. However, further reducing exposure is a public health goal because there is no clear toxicological threshold. The identification of the environmental determinants of BLLs as well as risk factors associated with high BLLs is important to update prevention strategies. We aimed to estimate the contribution of environmental sources of lead to different BLLs in children in France. We enrolled 484 children aged from 6months to 6years, in a nationwide cross-sectional survey in 2008-2009. We measured lead concentrations in blood and environmental samples (water, soils, household settled dusts, paints, cosmetics and traditional cookware). We performed two models: a multivariate generalized additive model on the geometric mean (GM), and a quantile regression model on the 10th, 25th, 50th, 75th and 90th quantile of BLLs. The GM of BLLs was 13.8μg/L (=1.38μg/dL) (95% confidence intervals (CI): 12.7-14.9) and the 90th quantile was 25.7μg/L (CI: 24.2-29.5). Household and common area dust, tap water, interior paint, ceramic cookware, traditional cosmetics, playground soil and dust, and environmental tobacco smoke were associated with the GM of BLLs. Household dust and tap water made the largest contributions to both the GM and the 90th quantile of BLLs. The concentration of lead in dust was positively correlated with all quantiles of BLLs even at low concentrations. Lead concentrations in tap water above 5μg/L were also positively correlated with the GM, 75th and 90th quantiles of BLLs in children drinking tap water. Preventative actions must target household settled dust and tap water to reduce the BLLs of children in France. The use of traditional cosmetics should be avoided whereas ceramic cookware should be limited to decorative purposes. Copyright © 2014 Elsevier Ltd. All rights reserved.

  15. Bayesian source term determination with unknown covariance of measurements

    Science.gov (United States)

    Belal, Alkomiet; Tichý, Ondřej; Šmídl, Václav

    2017-04-01

    Determination of a source term of release of a hazardous material into the atmosphere is a very important task for emergency response. We are concerned with the problem of estimation of the source term in the conventional linear inverse problem, y = Mx, where the relationship between the vector of observations y is described using the source-receptor-sensitivity (SRS) matrix M and the unknown source term x. Since the system is typically ill-conditioned, the problem is recast as an optimization problem minR,B(y - Mx)TR-1(y - Mx) + xTB-1x. The first term minimizes the error of the measurements with covariance matrix R, and the second term is a regularization of the source term. There are different types of regularization arising for different choices of matrices R and B, for example, Tikhonov regularization assumes covariance matrix B as the identity matrix multiplied by scalar parameter. In this contribution, we adopt a Bayesian approach to make inference on the unknown source term x as well as unknown R and B. We assume prior on x to be a Gaussian with zero mean and unknown diagonal covariance matrix B. The covariance matrix of the likelihood R is also unknown. We consider two potential choices of the structure of the matrix R. First is the diagonal matrix and the second is a locally correlated structure using information on topology of the measuring network. Since the inference of the model is intractable, iterative variational Bayes algorithm is used for simultaneous estimation of all model parameters. The practical usefulness of our contribution is demonstrated on an application of the resulting algorithm to real data from the European Tracer Experiment (ETEX). This research is supported by EEA/Norwegian Financial Mechanism under project MSMT-28477/2014 Source-Term Determination of Radionuclide Releases by Inverse Atmospheric Dispersion Modelling (STRADI).

  16. Determination of cadmium, lead and zinc in a candidate reference materials using isotope dilution mass spectrometry

    International Nuclear Information System (INIS)

    Munoz, Luis; Gras, Nuri; Quejido, Alberto; Fernandez, Marta

    2001-01-01

    The growing demands placed on analytical laboratories to ensure the reliability of their results, due to the introduction of systems of quality and to the increasing use of metrology in chemical measurements has led most laboratories to validate their methodologies and to control them statistically. One of the techniques used most often for these purposes is based on the use of reference materials. The proper use of these materials means that laboratory results may be traced to the International System of Units, analytical methodologies can be validated, instruments calibrated and chemical measurements harmonized. One of the biggest challenges in developing reference materials is that of certifying their properties, a process that has been defined as assigning a concentration value that is as close as possible to the true value together with its uncertainty. Organizations that produce reference materials use several options for their certification process, and among these is the use of a primary method. Among the primary methods recognized by the International Office of Weights and Measures is the Isotope Dilution Mass Spectrometry technique. The Chilean Nuclear Energy Commission, through its Reference Materials Program, has prepared a reference material of clam tissue, which has been chemically defined by different analytical methodologies applied in different national and international laboratories. This work describes the methodology developed with the CIEMAT for determining the elements lead, cadmium and zinc in the clam tissue reference material using the primary technique of Isotope Dilution Mass Spectrometry. The calculation is described for obtaining the spike amounts to be added to the sample and the procedure is explained for carrying out the isotopic exchange. The isotopic relationships 204 Pb/ 205 Pb, 111 Cd/ 114 Cd and 66 Zn/ 67 Zn were determined in an atomic emission spectrometer with a plasma source with the following characteristics: plasma

  17. Application of source-receptor models to determine source areas of biological components (pollen and butterflies)

    OpenAIRE

    M. Alarcón; M. Àvila; J. Belmonte; C. Stefanescu; R. Izquierdo

    2010-01-01

    The source-receptor models allow the establishment of relationships between a receptor point (sampling point) and the probable source areas (regions of emission) through the association of concentration values at the receptor point with the corresponding atmospheric back-trajectories, and, together with other techniques, to interpret transport phenomena on a synoptic scale. These models are generally used in air pollution studies to determine the areas of origin of chemical compounds measured...

  18. Calibration equations for energy-dispersive XRF determination of copper, iron and lead in copper ore slurries

    International Nuclear Information System (INIS)

    Lakosz, M.

    1976-01-01

    Calibration equations for the X-ray fluorescence analysis determination of copper, iron and lead in copper ore slurries have been derived and tested. The measurement of Ksub(α) lines of copper and iron and Lsub(α) line of lead excited by rays from 238 Pu source have been used. Si/Li detector coupled to multichannel analyzer and minicomputer have been applied in measurements. The matrix and density effect have been eliminated by additional measurement of back-scattered primary radiation. (author)

  19. The use of lead isotope analysis to identify potential sources of lead toxicosis in a juvenile bald eagle (Haliaeetus leucocephalus) with ventricular foreign bodies

    Science.gov (United States)

    Franzen-Klein, Dana; McRuer, David; Slabe, Vincent; Katzner, Todd

    2018-01-01

    A male juvenile bald eagle (Haliaeetus leucocephalus) was admitted to the Wildlife Center of Virginia with a left humeral fracture a large quantity of anthropogenic debris in the ventriculus, a blood lead level of 0.616 ppm, and clinical signs consistent with chronic lead toxicosis. Because of the poor prognosis for recovery and release, the eagle was euthanatized. Lead isotope analysis was performed to identify potential anthropogenic sources of lead in this bird. The lead isotope ratios in the eagle's femur (0.8773), liver (0.8761), and kidneys (0.8686) were most closely related to lead paint (0.8925), leaded gasoline (0.8450), and zinc smelting (0.8240). The lead isotope ratios were dissimilar to lead ammunition (0.8179) and the anthropogenic debris in the ventriculus. This case report documents foreign body ingestion in a free-ranging bald eagle and demonstrates the clinical utility of lead isotope analysis to potentially identify or exclude anthropogenic sources of lead poisoning in wildlife patients.

  20. Lead in the blood of children living close to industrial point sources in Bulgaria and Poland

    Science.gov (United States)

    Willeke-Wetstein, C.; Bainova, A.; Georgieva, R.; Huzior-Balajewicz, A.; Bacon, J. R.

    2003-05-01

    ln Eastern European countries some industrial point sources are still suspected to have unacceptable emission rates of lead that pose a major health risk in particular to children. An interdisciplinary research project under the auspices of the EU had the aims (I) to monitor the current contamination of two industrial zones in Bulgaria and Poland, (2) to relate the Pb levels in ecological strata to the internal exposure of children, (3) to develop public health strategies in order to reduce the health risk by heavy metals. The human monitoring of Pb in Poland did not show increased health risks for the children living in an industrial zone close to Krakow. Bulgarian children, however, exceeded the WHO limit of 100 μg lead per litre blood by over one hundred percent (240 μg/1). Samples of soil, fodder and livestock organs showed elevated concentrations of lead. Recent literature results are compared with the findings in Bulgaria and Poland. The sources of the high internal exposure of children are discussed. Public health strategies to prevent mental dysfunction in Bulgarian children at risk include awareness building and social masures.

  1. Levels and sources of particulate lead in air at Kwabenya, Accra, Ghana

    International Nuclear Information System (INIS)

    Ofosu, F.G.; Aboh, I.J.K.

    2008-01-01

    The Government of Ghana by Legislation Instrument L.I 1732 banned the production, importation, storage, sale and use of leaded gasoline in Ghana with effect from 1 st January 2004. The aim of this work is to find out the contribution of lead to the atmospheric aerosol two years after the coming into force of the ban. The sampling was done using a Gent sampler with stacked filter units and the aerosol collected size fractionated into PM 2.5 (fine) and PM 10-2.5 (Coarse). Energy dispersive x-ray fluorescence (EDXRF) analysis was used to identify and quantify lead (Pb) and other elements in both the coarse and fine fractions. The average concentration of Pb in the ambient air was 1.49 ngm -3 and 0.70 ngm -3 for the coarse and fine fractions respectively. The average total of both the coarse and fine fractions (which is PM 10 ) was 2.19 ngm -3 , which is well below the US EPA set standard of 1.5 μgm -3 . Source apportionment on the fine fraction using Principal Component Analysis (PCA) showed that mostly soil/dust and to a lesser extent combustion processes were the sources of the Pb. (au)

  2. Two Functionally Distinct Sources of Actin Monomers Supply the Leading Edge of Lamellipodia

    Science.gov (United States)

    Vitriol, Eric A.; McMillen, Laura M.; Kapustina, Maryna; Gomez, Shawn M.; Vavylonis, Dimitrios; Zheng, James Q.

    2015-01-01

    Summary Lamellipodia, the sheet-like protrusions of motile cells, consist of networks of actin filaments (F-actin) regulated by the ordered assembly from and disassembly into actin monomers (G-actin). Traditionally, G-actin is thought to exist as a homogeneous pool. Here, we show that there are two functionally and molecularly distinct sources of G-actin that supply lamellipodial actin networks. G-actin originating from the cytosolic pool requires the monomer binding protein thymosin β4 (Tβ4) for optimal leading edge localization, is targeted to formins, and is responsible for creating an elevated G/F-actin ratio that promotes membrane protrusion. The second source of G-actin comes from recycled lamellipodia F-actin. Recycling occurs independently of Tβ4 and appears to regulate lamellipodia homeostasis. Tβ4-bound G-actin specifically localizes to the leading edge because it doesn’t interact with Arp2/3-mediated polymerization sites found throughout the lamellipodia. These findings demonstrate that actin networks can be constructed from multiple sources of monomers with discrete spatiotemporal functions. PMID:25865895

  3. Determination of source term for Krsko NPP extended fuel cycle

    International Nuclear Information System (INIS)

    Nemec, T.; Persic, A.; Zagar, T.; Zefran, B.

    2004-01-01

    The activity and composition of the potential radioactive releases (source term) is important in the decision making about off-site emergency measures in case of a release into environment. Power uprate of Krsko NPP during modernization in 2000 as well as changing of the fuel type and the core design have influenced the source term value. In 2003 a project of 'Jozef Stefan' Institute and Slovenian nuclear safety administration determined a plantspecific source term for new conditions of fuel type and burnup for extended fuel cycle. Calculations of activity and isotopic composition of the core have been performed with ORIGEN-ARP program. Results showed that the core activity for extended 15 months fuel cycle is slightly lower than for the 12 months cycles, mainly due to larger share of fresh fuel. (author)

  4. Preferred orientation determination using line source x-ray diffraction

    International Nuclear Information System (INIS)

    Kimmel, G.; Shmarjahu, D.

    1977-10-01

    A texture goniometer has been attached to a diffractometer connected to a line-focus x-ray source. Reasonable results are obtained for the texture of rolled sheets and the test procedure is given. To illustrate the test procedure, the determination of preferred orientation in cold-rolled copper is described, as compared with random powder of sintered copper. Improvements of the measurements are proposed

  5. Autonomous Motivation for Teaching: How Self-Determined Teaching May Lead to Self-Determined Learning

    Science.gov (United States)

    Roth, Guy; Assor, Avi; Kanat-Maymon, Yaniv; Kaplan, Haya

    2007-01-01

    This study examined teachers' experience of autonomous motivation for teaching and its correlates in teachers and students. It was hypothesized that teachers would perceive various motivations posited by E. L. Deci and R. M. Ryan's (2000) self-determination theory as falling along a continuum of autonomous motivation for teaching. Autonomous…

  6. Experimental study using of a G-M counter and {sup 137}Cs source to measure the HVL with lead

    Energy Technology Data Exchange (ETDEWEB)

    Kwon, Dae Cheol [Dept. of Radiological Science, College of Health Science, Shinhan University, Uijeongbu (Korea, Republic of); Dong, Kyung Rae [Dept. of Radiological Technology, Gwangju Health University, Gwangju (Korea, Republic of)

    2016-11-15

    HVL(half-value layer) of lead was measured experimentally using a lead and {sup 137}Cs (370 kBq) source and a G-M counter in which is used a lot of material for shielding HVL measured. {sup 137}Cs in holder to 10 cm and start measuring the radiation. Continue addition of lead of the lead thickness of 1 mm one by one to continue the measurement. By measuring four times the natural radiation of 100 seconds and records the count value and the average rate to be displayed on the meter. Background radiation was a 4 times a count rate and the average 108 (100 s{sup -1}) as a result of measuring the average measurement, the standard deviation was determined to be 1.08 (s{sup -1}). An increase in the thickness of lead initial count rate starting from 920 (N) count rate is decreased with increase in the thickness of lead. Net counting rate, starting with the initial 8.12 (s{sup -1}) showed a decrease with increasing thickness, the standard deviation of the results was decreased from 0.303 (s{sup -1}) to 0.196 (s{sup -1}). Net counting rate is reduced to obtain the result that each half thickness of nappan about 7 mm. Was reduced similarly to the exponential function graph correlation coefficient (R{sup 2}) was found to be 0.9869. Half-value layer which is the initial net counting rate 7.514 (s{sup -1}) is a half the 7 mm to 3.757 (s{sup -1}). In conclusion, it was confirmed the theoretical HVL of lead 7.19 mm and experimentally measured results matched the measured HVL 7 mm.

  7. Application of the radioreagent method to the determination of trace quantities of lead

    International Nuclear Information System (INIS)

    Figueiredo, A.M.G.; Saiki, M.; Lima, F.W. de

    1983-01-01

    The radioreagent method of analysis was applied to determine trace quantities of lead in several types of samples. This method is based on the extraction of radioactive cobalt, displaced by lead from the cobalt chelate of ethylenediaminetetraacetate labeled with 60 Co, into a tetracycline-benzyl alcohol solution. The radioactivity of the released cobalt, extracted into the organic phase, measured by menas of a single channel gamma-ray analyzer coupled to a Na(T1) scintillation detector, is proportional to the lead concentration. The elements which might interfere with the analysis were removed by a chemical separation procedure of lead using dithizone. The method was applied for lead determination in air samples, gasoline and samples from the International Atomic Energy Agency, namely: simulated air filter (Air-3), fresh water (W-3), dried animal whole blood(A-2) and calcinated animal bone (A3/1). The sensitivity, accuracy and precision of the method were also discussed. (Author) [pt

  8. Record of Anthropocene pollution sources of lead in disturbed peatlands from Southern Poland

    Science.gov (United States)

    Fiałkiewicz-Kozieł, Barbara; De Vleeschouwer, François; Mattielli, Nadine; Fagel, Nathalie; Palowski, Bernard; Pazdur, Anna; Smieja-Król, Beata

    2018-04-01

    The importance of human impacts on Earth has led to the proposal of a new geologic epoch called the Anthropocene. However markers, recognizable in all records, are required to define this period. Here we combine elemental geochemistry with stable lead (Pb) isotopes and mineralogical analyses to decipher the sources of lead in two exploited ombrotrophic peat bogs (Puścizna Mała and Puścizna Krauszowska) from Southern Poland. The most disturbed parts of the cores, distinguished using bulk density and age-depth models (22-45 cm in PM and 22-46 cm in PK), were excluded from the interpretation. The two studied cores record ca. 2000 years of variations in lead accumulation rates and isotopic compositions. In the lowest part of the cores (2nd to 4th century AD for Puścizna Mała and 2nd century BC to 2nd century AD for Puścizna Krauszowska), the 206Pb/207Pb ratios (1.188) are consistent with natural supplies from the erosion of the nearby Tatra Mountains. From the 9th to the 19th century AD, 206Pb/207Pb ratios (1.176-1.179) are similar to the signatures obtained from Polish galena ores. The highest Pb accumulation rates are found around 1950 AD and reflect the primary influence of bituminous coal combustion together with the secondary influence of leaded gasoline. This result agrees with the occurrence and abundance of spheroidal aluminosilicates, an unambiguous marker of human industrial activity and coal burning as well as with the acceleration of Zn, Cd and Fe accumulation rate. Our results provide evidence that similar geochemical patterns exist in both analysed cores despite differences in the history of peatland exploitation. Therefore, given that extra care is taken to identify the disturbed peat layers, exploited peatlands can be used to record past changes in lead isotopic signature during the Anthropocene.

  9. Determination of Lead and Cadmium in cow’s Milk and Elimination by Using Titanium Dioxide Nanoparticles

    Directory of Open Access Journals (Sweden)

    Haniyeh Moallem Bandani

    2016-10-01

    Full Text Available Background and Objectives: Heavy metals such as cadmium and lead are the most important toxins spreading through various ways like water, soil, and air in nature and easily enter human food chain. It is essential to determine the cumulative and harmful effects of these metals in nutrients, especially in cow milk because it is a unique source of food for all ages and it contains both essential and nonessential trace elements. Materials and Methods: A total of 100 milk samples were directly collected from healthy cows in Zabol located on east of Iran. The samples were tested to determine lead and cadmium residues. The rates of the heavy metals were determined using a Rayleigh atomic absorption spectrum equipped with hollow cathode lamps (HCL at 283.3 nm for lead (Pb and at 228.8 nm for cadmium (Cd. By using the photo-catalytic titanium dioxide nanoparticles, these toxic metals were removed. Results: The mean ± SD of the concentration of lead and cadmium in raw milk were 9.175± 2.5 and 4.557 ± 1.081 ppb, respectively. Also, the P-values of Kalmogorov– Smiranov test for lead and cadmium were respectively 0.057 ppb (P>0.05 and 0.435 ppb (P>0.05. TiO2 nanoparticles were used to eliminate and remove lead and cadmium in milk samples. The results showed that there was a significant difference between lead and cadmium contents before and after adding TiO2 nanoparticles (P<0.05. Conclusions: According to results of this study, there was a very low amount of toxic metals. So, it seems that it is not necessary to use TiO2 in milk samples but these days it used frequently as an additive to some samples like milk to remove these pollutants. Keywords: lead, cadmium, milk, atomic absorption spectroscopy, TiO2 nanoparticles

  10. Isotopic identification of natural vs. anthropogenic lead sources in marine sediments from the inner Ria de Vigo (NW Spain)

    Energy Technology Data Exchange (ETDEWEB)

    Alvarez-Iglesias, P., E-mail: palvarez@uvigo.es [Department of Marine Geosciences and Land Use Management, Faculty of Marine Sciences, University of Vigo (Spain); Laboratorio de Analisis Quimico Instrumental, C.A.C.T.I., Universidad de Vigo (Spain); Rubio, B., E-mail: brubio@uvigo.es [Department of Marine Geosciences and Land Use Management, Faculty of Marine Sciences, University of Vigo (Spain); Millos, J., E-mail: jmillos@uvigo.es [Laboratorio de Analisis Quimico Instrumental, C.A.C.T.I., Universidad de Vigo (Spain)

    2012-10-15

    San Simon Bay, the inner part of the Ria de Vigo (NW Spain), an area previously identified as highly polluted by Pb, was selected for the application of Pb stable isotope ratios as a fingerprinting tool in subtidal and intertidal sediment cores. Lead isotopic ratios were determined by inductively coupled plasma mass spectrometry on extracts from bulk samples after total acid digestion. Depth-wise profiles of {sup 206}Pb/{sup 207}Pb, {sup 206}Pb/{sup 204}Pb, {sup 207}Pb/{sup 204}Pb, {sup 208}Pb/{sup 204}Pb and {sup 208}Pb/{sup 207}Pb ratios showed, in general, an upward decrease for both intertidal and subtidal sediments as a consequence of the anthropogenic activities over the last century, or centuries. Waste channel samples from a nearby ceramic factory showed characteristic Pb stable isotope ratios different from those typical of coal and petrol. Natural isotope ratios from non-polluted samples were established for the study area, differentiating sediments from granitic or schist-gneiss sources. A binary mixing model employed on the polluted samples allowed estimating the anthropogenic inputs to the bay. These inputs represented between 25 and 98% of Pb inputs in intertidal samples, and 9-84% in subtidal samples, their contributions varying with time. Anthropogenic sources were apportioned according to a three-source model. Coal combustion-related emissions were the main anthropogenic source Pb to the bay (60-70%) before the establishment of the ceramic factory in the area (in the 1970s) which has since constituted the main source (95-100%), followed by petrol-related emissions. The Pb inputs history for the intertidal area was determined for the 20th century, and, for the subtidal area, the 19th and 20th centuries. -- Highlights: Black-Right-Pointing-Pointer Pb stable isotope ratios were applied to study Pb sources in coastal sediments. Black-Right-Pointing-Pointer Pb isotopic ratios were determined for pre-pollution and for industrial samples. Black

  11. Automated Determination of Magnitude and Source Length of Large Earthquakes

    Science.gov (United States)

    Wang, D.; Kawakatsu, H.; Zhuang, J.; Mori, J. J.; Maeda, T.; Tsuruoka, H.; Zhao, X.

    2017-12-01

    Rapid determination of earthquake magnitude is of importance for estimating shaking damages, and tsunami hazards. However, due to the complexity of source process, accurately estimating magnitude for great earthquakes in minutes after origin time is still a challenge. Mw is an accurate estimate for large earthquakes. However, calculating Mw requires the whole wave trains including P, S, and surface phases, which takes tens of minutes to reach stations at tele-seismic distances. To speed up the calculation, methods using W phase and body wave are developed for fast estimating earthquake sizes. Besides these methods that involve Green's Functions and inversions, there are other approaches that use empirically simulated relations to estimate earthquake magnitudes, usually for large earthquakes. The nature of simple implementation and straightforward calculation made these approaches widely applied at many institutions such as the Pacific Tsunami Warning Center, the Japan Meteorological Agency, and the USGS. Here we developed an approach that was originated from Hara [2007], estimating magnitude by considering P-wave displacement and source duration. We introduced a back-projection technique [Wang et al., 2016] instead to estimate source duration using array data from a high-sensitive seismograph network (Hi-net). The introduction of back-projection improves the method in two ways. Firstly, the source duration could be accurately determined by seismic array. Secondly, the results can be more rapidly calculated, and data derived from farther stations are not required. We purpose to develop an automated system for determining fast and reliable source information of large shallow seismic events based on real time data of a dense regional array and global data, for earthquakes that occur at distance of roughly 30°- 85° from the array center. This system can offer fast and robust estimates of magnitudes and rupture extensions of large earthquakes in 6 to 13 min (plus

  12. Method to determine the strength of a neutron source

    Energy Technology Data Exchange (ETDEWEB)

    Vega C, H.R.; Manzanares A, E.; Hernandez D, V.M.; Chacon R, A.; Mercado, G.A. [UAZ, A.P. 336, 98000 Zacatecas (Mexico); Gallego, E.; Lorente, A. [Depto. Ingenieria Nuclear, Universidad Politecnica de Madrid, (Spain)

    2006-07-01

    The use of a gamma-ray spectrometer with a 3 {phi} x 3 NaI(Tl) detector, with a moderator sphere has been studied in the aim to measure the neutron fluence rate and to determine the source strength. Moderators with a large amount of hydrogen are able to slowdown and thermalize neutrons; once thermalized there is a probability that thermal neutron to be captured by hydrogen producing 2.22 MeV prompt gamma-ray. The pulse-height spectrum collected in a multicharmel analyzer shows a photopeak around 2.22 MeV whose net area is proportional to total neutron fluence rate and to the neutron source strength. The characteristics of this system were determined by a Monte Carlo study using the MCNP 4C code, where a detailed model of the Nal(Tl) was utilized. As moderators 3, 5, and 10 inches-diameter spheres where utilized and the response was calculated for monoenergetic and isotopic neutrons sources. (Author)

  13. Method of analysis for the determination of lead and cadmium in fresh meat

    NARCIS (Netherlands)

    Ruig, de W.G.

    1980-01-01

    This report comprises the result of the RIKILT of an intercomparison on the determination of lead and cadmium in bovine liver and bovine kidney. The aim of this round robbin was to check a wet ashing procedure followed by a flame AAS determination as described too in EEC doc. 2266/VI/77. Special

  14. Lead precipitation fluxes at tropical oceanic sites determined from 210Pb measurements

    International Nuclear Information System (INIS)

    Settle, D.M.; Patterson, C.C.; Turekian, K.K.; Cochran, J.K.

    1982-01-01

    Concentrations of lead, 210 Pb, and 210 Po were measured in rain selected for least influence by local sources of contamination at several tropical and subtropical islands (Enewetak; Pigeon Key, Florida; and American Samoa) and shipboard stations (near Bermuda and Tahiti). Ratios expressed as ng Pb/dpm 210 Pb in rain were 250--900 for Pigeon Key (assuming 12% adsorption for 210 Pb and no adsorption for lead), depending on whether the air masses containing the analyzed rain came from the Caribbean or from the continent, respectively; about 390 for the northern Sargasso Sea downwind from emissions of industrial lead in North America; 65 for Enewetak, remote from continental emissions of industrial lead in the northern hemisphere; and 14 near Tahiti, a remote location in the southern hemisphere where industrial lead emissions to the atmosphere are much less than in the northern hemisphere. (The American Samoa sample yielded a higher ratio than Tahiti; the reason for this is not clear but may be due to local Pb sources). The corresponding fluxes of lead to the oceans, based on measured or modeled 210 Pb precipitation fluxes, are about 4 ng Pb/cm 2 y for Tahiti, 10 for Enewetak, and 270 for the Sargasso Sea site, and between 110 to 390 at Pigeon Key

  15. Instrumental neutron-activation determination of impurities in lead and titanium compounds

    Energy Technology Data Exchange (ETDEWEB)

    Popova, I L

    1980-01-01

    Instrumental neutron-activation analysis was used to determine 22 impurities in lead and titanium compounds (e.g. PbO, Pb/NO3/2, and TiO2) used as raw materials for ferroelectrics. Five elements (Al, V, Mn, Sc, and Se) were determined by short-lived isotopes and 17 elements were determined by long-lived isotopes. The detection limits were 7 x 10 to the -3rd to 2 x 10 to the -8th %. A substantial difference in concentrations of certain impurity elements has been found in different series of lead and titanium oxides of similar purity.

  16. The determination of aluminum, copper, iron, and lead in glycol formulations by atomic absorption spectroscopy

    Science.gov (United States)

    1977-01-01

    Initial screening tests and the results obtained in developing procedures to determine Al, Cu, Fe, and Pb in glycol formulations are described. Atomic absorption completion was selected for Cu, Fe and Pb, and after comparison with emission spectroscopy, was selected for Al also. Before completion, carbon, iron, and lead are extracted with diethyl dithio carbamate (DDC) into methyl isobutyl ketone (MIBK). Aluminum was also extracted into MIBK using 8-hydroxyquinoline as a chelating agent. As little as 0.02 mg/l carbon and 0.06 mg/l lead or iron may be determined in glycol formulations. As little as 0.3 mg/l aluminum may be determined.

  17. Source apportionment and environmental fate of lead chromates in atmospheric dust in arid environments.

    Science.gov (United States)

    Meza-Figueroa, Diana; González-Grijalva, Belem; Romero, Francisco; Ruiz, Joaquin; Pedroza-Montero, Martín; Rivero, Carlos Ibañez-Del; Acosta-Elías, Mónica; Ochoa-Landin, Lucas; Navarro-Espinoza, Sofía

    2018-03-07

    The environmental fate of lead derived from traffic paint has been poorly studied in developing countries, mainly in arid zones. For this purpose, a developing city located in the Sonoran desert (Hermosillo, Mexico), was chosen to conduct a study. In this paper the lead chromate (crocoite) sources in atmospheric dust were addressed using a combination of Raman microspectroscopy, X-ray diffraction, scanning electron microscopy (SEM), and Pb isotope measurements. A high concentration of Pb and Cr as micro- and nanostructured pigments of crocoite is reported in yellow traffic paint (n=80), road dust (n=146), settled dust in roofs (n=21), and atmospheric dust (n=20) from a developing city located in the Sonoran Desert. 10 samples of peri-urban soils were collected for local geochemical background. The paint photodegradation and erosion of the asphaltic cover are enhanced by the climate, and the presence of the mineral crocoite (PbCrO 4 ) in road dust with an aerodynamic diameter ranging from 100nm to 2μm suggests its integration into the atmosphere by wind resuspension processes. A positive PbCr correlation (R 2 =0.977) was found for all studied samples, suggesting a common source. The Pb-isotope data show signatures in atmospheric dust as a product of the mixing of two end members: i) local soils and ii) crocoite crystals as pigments in paint. The presence of lead chromates in atmospheric dust has not been previously documented in Latin America, and it represents an unknown health risk to the exposed population because the identified size of crystals can reach the deepest part of lungs. Copyright © 2018 Elsevier B.V. All rights reserved.

  18. Measurement of disintegration rates of small [60Co]Co sources in lead containers by the sum-peak method

    International Nuclear Information System (INIS)

    Kawano, Takao; Ebihara, Hiroshi

    1991-01-01

    The sum-peak method has been applied to determine the disintegration rates of two small [ 60 Co]Co sources (30 and 350 kBq) in lead containers with several thickness by using a NaI(Tl) detector. The experimental results showed that the sum-peak method was perfectly effective for the determination of the disintegration rates (unrelated to the thicknesses of the containers) of the 350 kBq source. The sum-peak method was also absolutely effective for the 30 kBq source in the case of containers with thicknesses of 15 mm and less, but in the cases of those with thicknesses of 21, 27 and 33 mm, the disintegration rates were under-estimated and the deviations from the true disintegration rate increased rapidly with increasing thicknesses of the containers. We presume that the under-estimation of the disintegration rates was the result of the over-estimation of the areas under the sum peaks, caused by the interference of the γ-ray (2614 keV) emitted from the naturally occurring radionuclide 208 Tl. (author)

  19. Determination of stable isotope ratio of lead in airborne particulate matter by ICP-MS

    International Nuclear Information System (INIS)

    Mukai, Hitoshi; Ambe, Yoshinari

    1990-01-01

    ICP-MS was applied to the measurement of stable isotope ratios of lead, which are used as an indicator of the source of lead in airborne particulate matter. For the measurement of lead isotopes ratios, the influences of machine conditions, lead concentration and matrix elements to the precision and accuracy of the measurements were studied. At a scanning mode, dwell time of 40∼160 μs gave the best precision to the isotope ratio measurements; about 0.3 % of R.S.D. for 206 Pb/ 207 Pb and 206 Pb/ 208 Pb, 0.6 % for 206 Pb/ 204 Pb. Precision of the measurement was better at a high concentration of lead in sample solution. The observed value of 206 Pb/ 207 Pb ratio was not affected by the lead concentration, but in the cases of 206 Pb/ 204 Pb and 206 Pb/ 208 Pb, about 1 % of the value changed in the observed ratios with the lead concentration of 100∼500 μg/l. Six matrix elements (Na, K, Ca, Mg, Al, Fe) did not affect the observed isotope ratios up to 200 mg/l. The lead isotope ratios of reference materials {Urban Particulates (NIST) and Vehicle Exhausted Particulates (NIES)} were measured by using two kinds of sample; crude sample and lead-isolated sample from matrix elements by anodic deposition. Both cases gave the same isotope ratio values, therefore, lead isotope ratios in airborne particulate samples can be measured by ICP-MS without any separation of lead from matrix elements. (author)

  20. The determination of levels of mercury, cadmium and lead in water samples from Naivasha area, Kenya

    International Nuclear Information System (INIS)

    Muigai, P.G.; Kamau, G.N.; Kinyua, A.M.

    1995-01-01

    The analysis of mercury, cadmium and lead in water samples from different environments (Lake Naivasha, River Malewa boreholes and Olkaria geothermal wells) in Naivasha region and their possible origins are reported. The levels of mercury and lead in the water samples were above the maximum permissible limits of 0.005 mg/1 and 0.1 mg/1 respectively, as stipulated by the WHO. On the other hand, 83.3% of the samples had cadmium levels above the maximum permissible limit of 0.01mg/1 in drinking water by WHO. The mercury and lead levels were also higher than those previously obtained from different regions of Kenya, while those for cadmium were within the corresponding range. Possible sources of elevated values were the geology of the surrounding area, sewage treatment works, use of phosphate rock fertilizers and lead fuels.(author)

  1. ANL calculational methodologies for determining spent nuclear fuel source term

    International Nuclear Information System (INIS)

    McKnight, R. D.

    2000-01-01

    Over the last decade Argonne National Laboratory has developed reactor depletion methods and models to determine radionuclide inventories of irradiated EBR-II fuels. Predicted masses based on these calculational methodologies have been validated using available data from destructive measurements--first from measurements of lead EBR-II experimental test assemblies and later using data obtained from processing irradiated EBR-II fuel assemblies in the Fuel Conditioning Facility. Details of these generic methodologies are described herein. Validation results demonstrate these methods meet the FCF operations and material control and accountancy requirements

  2. Application of radio-reagent method in the determination of lead trace amounts

    International Nuclear Information System (INIS)

    Figueiredo, A.M.G.

    1983-01-01

    A radiometric method for trace analysis of lead was established, based on the displacement reaction between lead and the complex cobalt - ethylenediaminetetracetate labelled with 60 Co (Co* - EDTA), which is named radioreagent. The radioactive cobalt displaced by lead is separated from the excess of radioreagent by the solvent extraction technique, using a solution of tetracycline (Tc) in benzyl alcohol. The activity of the extracted cobalt is then measured by means of a single-channel gamma-ray analyser coupled to a NaI (Tl) scintillation detector, the activity being proportional to the lead concentration, in a range from 2.5 to 150 μg. The interference of several elements (V, Th, Sc, Fe, La, Yb, Cu, Cd, Zn, Mn, Ni, Co, Al and Sn) was investigated by means of a previous separation between lead and these interfering elements. The analyses of artificial samples containing lead and the interfering elements gave a yield of 91.1 + - 3.2 %. The detection limit achieved by the method was 3.3 μg of lead. The radioreagent method was applied to lead analysis of samples from IAEA, namely: simulated air filter (Air-3), fresh water (W-3), dried animal blood (A-2) and calcinated animal bone (A-3/1). Lead was also determined in gasoline samples and air samples, these latter collected in the surroundings of the IPEN/CNEN/SP (Brazil). (Author) [pt

  3. Determinants of maternal and umbilical blood lead levels: a cross-sectional study, Mosul, Iraq

    Directory of Open Access Journals (Sweden)

    Al-Jomard Raghad A

    2009-03-01

    Full Text Available Abstract Background The populations who are most sensitive to lead exposure from various sources are pregnant women and their newborns. Aiming to explore the presence of correlation between maternal and cord blood lead levels and to identify potential predictors that may influence both levels, the present study has been conducted. Methods A cross-sectional study was conducted covering 350 full terms maternal-newborns pairs from Mosul maternity hospitals. Data were obtained directly from women just before delivery by the use of a detailed questionnaire form. Maternal and umbilical blood lead levels were estimated using LEADCARE® Blood Lead Testing System and Kits. Results A positive significant correlation was found between maternal and cord blood lead values (r = 0.856, p = 0.001. By backward stepwise logistic regression analysis the followings emerged as significant potential predictors of high maternal blood lead: low parity, smoking and Hb level Conclusion Study results have provided baseline data needed to be transformed to decision makers to implement measures to eliminate lead from the environment and protect future generation from its deleterious effects.

  4. Determination of lead and cadmium in urine by electrothermal atomization atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Vasil'eva, L.A.; Grinshtejn, I.L.; Gucher, Sh.; Izgi, B.

    2008-01-01

    The applicability of a DETATA sorbent to the preconcentration of lead and cadmium followed by the determination of these elements in urine using atomic absorption spectrometry with electrothermal atomization was demonstrated. After preconcentration by a factor of 10, the limits of detection were 0.01 and 0.2 μg/l for cadmium and lead, respectively. The accuracy of the results was supported by the analysis of Seronorm TM Trace Elements Urine Batch no.101021 [ru

  5. The determination of neutron energy spectra of radioisotope sources

    International Nuclear Information System (INIS)

    Lutkin, J.E.

    1975-08-01

    The neutron energy spectrum of a 241 Am-Be radioisotope neutron source has been determined by use of a time of flight neutron spectrometer; this spectrometer not being subject to the same uncertainties as a scintillation spectrometer. Neutron spectra have been determined using a scintillation spectrometer with which the effects of instrumental uncertainties, particularly the pulse shape discrimination have been assessed. In the course of the development of the time flight spectrometer a zero crossover pulse shape discrimination system was developed in order to reduce the unwanted background. Using this system a quantitative survey of pulse shape discrimination with experimental and commercial liquid and plastic organic scintillators were carried out. In addition the pulse shape discrimination properties of inorganic scintillators were also examined. (author)

  6. Determination of lead and arsenic in tobacco and cigarettes: an important issue of public health.

    Science.gov (United States)

    Lazarević, Konstansa; Nikolić, Dejan; Stosić, Ljiljana; Milutinović, Suzana; Videnović, Jelena; Bogdanović, Dragan

    2012-03-01

    Contents of lead and arsenic were determined in 617 tobacco samples and 80 samples of cigarettes. The mean content of lead in tobacco was 0.93 microg/g (range 0.02-8.56 microg/g) and arsenic was 0.15 microg/g (range arsenic was 0.11 microg/g (range arsenic content among samples of tobacco and samples of cigarettes. Positive correlation between lead and arsenic contents in tobacco was found (r = 0.22; p arsenic in tobacco and cigarettes in other studies and discuss the influence of smoking to lead and arsenic exposure and health. In conclusion, at the same time with the implementation of tobacco use prevention programmes it is advisable to implement continuous monitoring of lead and arsenic in tobacco and cigarettes in order to reduce the health risk due to exposure of these metals.

  7. Method of determining paper-deposited materials, eg. lead, by their reaction with radioactive krypton

    International Nuclear Information System (INIS)

    Tolgyessy, J.; Pruzinec, J.

    1976-01-01

    The invention claims a method of determining substances on a paper carrier based on the substance reaction with 85 Kr gas and the measurement of radioactivity of the kryptonate formed. Lead is shown as an example. Different amounts of lead acetate were deposited on Whatman 2 chromatographic paper as was an unknown sample of Pb salt. The paper was exposed to a 2.5 mCi 85 Kr atmosphere for 48 hours. The activity of the individual spots was then measured, a calibration curve established and the amount of lead in the analyzed sample read-out. (Ha)

  8. Stationary sources of airborne lead: a comparison of emissions data for southern California.

    Science.gov (United States)

    Harris, Allison R; Fifarek, Brian J; Davidson, Cliff I; Blackmon, Rebecca Lankey

    2006-04-01

    Estimates for the air releases of lead from stationary point sources are considered for the South Coast Air Basin of California. We have examined four databases published by U.S. Environmental Protection Agency, the California Air Resources Board, and the South Coast Air Quality Management District. Our analysis indicates that none of the databases includes every emitting facility in the South Coast Air Basin of California and that other discrepancies among the databases exist. Additionally, the data have been analyzed for temporal variation, and some of the California Air Resources Board data are not current. The South Coast Air Quality Management District inventory covers 12 times more facilities in 2001 than in 1996. From this analysis, we conclude that all four of the databases would benefit by sharing data, increasing transparency, analyzing uncertainty, and standardizing emission estimation methods.

  9. Determining the VLF/ULF source height using phase measurements

    Science.gov (United States)

    Ryabov, A.; Kotik, D. S.

    2012-12-01

    Generation of ULF/VLF waves in the ionosphere using powerful RF facilities has been studied for the last 40 years, both theoretically and experimentally. During this time, it was proposed several mechanisms for explaining the experimental results: modulation of ionospheric currents based on thermal nonlinearity, ponderomotive mechanisms for generation both VLF and ULF signals, cubic nonlinearity, etc. According mentioned above mechanisms the VLF/ULF signal source could be located in the lower or upper ionosphere. The group velocity of signal propagation in the ionosphere is significantly smaller than speed of light. As a result the appreciable time delay of the received signals will occur at the earth surface. This time delay could be determine by measuring the phase difference between received and reference signals, which are GPS synchronized. The experiment on determining the time delay of ULF signal propagation from the ionospheric source was carried out at SURA facility in 2012 and the results are presented in this paper. The comparison with numerical simulation of the time delay using the adjusted IRI model and ionosonde data shows well agreement with the experimental observations. The work was supported by RFBR grant 11-02-00419-a and RF Ministry of education and science by state contract 16.518.11.7066.

  10. Induced Radioactivity in Lead Shielding at the National Synchrotron Light Source.

    Science.gov (United States)

    Ghosh, Vinita J; Schaefer, Charles; Kahnhauser, Henry

    2017-06-01

    The National Synchrotron Light Source (NSLS) at Brookhaven National Laboratory was shut down in September 2014. Lead bricks used as radiological shadow shielding within the accelerator were exposed to stray radiation fields during normal operations. The FLUKA code, a fully integrated Monte Carlo simulation package for the interaction and transport of particles and nuclei in matter, was used to estimate induced radioactivity in this shielding and stainless steel beam pipe from known beam losses. The FLUKA output was processed using MICROSHIELD® to estimate on-contact exposure rates with individually exposed bricks to help design and optimize the radiological survey process. This entire process can be modeled using FLUKA, but use of MICROSHIELD® as a secondary method was chosen because of the project's resource constraints. Due to the compressed schedule and lack of shielding configuration data, simple FLUKA models were developed. FLUKA activity estimates for stainless steel were compared with sampling data to validate results, which show that simple FLUKA models and irradiation geometries can be used to predict radioactivity inventories accurately in exposed materials. During decommissioning 0.1% of the lead bricks were found to have measurable levels of induced radioactivity. Post-processing with MICROSHIELD® provides an acceptable secondary method of estimating residual exposure rates.

  11. Atomic absorption spectrometric determination of copper, zinc, and lead in geological materials

    Science.gov (United States)

    Sanzolone, R.F.; Chao, T.T.

    1976-01-01

    An atomic absorption spectrometric method is described for the determination of copper, zinc, and lead in geological materials. The sample is digested with HF-HCl-H2O2; the final solution for analysis is in 10 % (v/v) HCl. Copper and zinc are determined directly by aspirating the solution into an air-acetylene flame. A separate aliquot of the solution is used for determination of lead; lead is extracted into TOPO-MIBK from the acidic solution in the presence of iodide and ascorbic acid. For a 0.50-g sample, the limits of determination are 10-2000 p.p.m. for Cu and Zn, and 5-5000 p.p.m. for Pb. As much as 40 % Fe or Ca. and 10 % Al, Mg, or Mn in the sample do not interfere. The proposed method can be applied to the determination of copper, zinc, and lead in a wide range of geological materials including iron- and manganese-rich, calcareous and carbonate samples. ?? 1976.

  12. Simultaneous determination of lead, cadmium and zinc in Metro Manila air particulates by anodic stripping voltammetry

    International Nuclear Information System (INIS)

    Castaneda, Soledad S.

    1999-02-01

    Air particulate samples were collected from two monitoring stations in Metro Manila using a 'Gent' type dichotomous sampler for pollutant source apportionment studies. Samples were collected in two fractions: a fine fraction with aerodynamic diameter, d p p 3 : HCL: HF, 4: 1: 1) for at least 20 minutes with subsequent heating at lower power settings for a total of 20 minutes more, effectively decomposed the sample with complete recovery of the elements. The digests were evaporated to near dryness to eliminate the troublesome effect of HF and HNO 3 and to decrease acidity of the electrolytic solution to pH ≥ 2. At pH 2, the addition of at least 0.01 M KCl was needed to improve sensitivity. The formation of Zn-Cu intermetallic compounds which interfered in the accurate quantitation of zinc was eliminated by addition of gallium as a 'third' element. The amount of gallium needed varied from sample to sample and was affected by the pH of the solution. The DPASV parameters found to be optimum for the analysis of the air particulate samples are as follows: pulse amplitude, 50 mV; scan rate, 10 mV/sec; E dep , - 1.30 V; t dep , 2 min; and RDE rotation rate, 1500 rpm. Detection limits of 0.2 ppb for zinc, 0.6 ppb for lead, and 0.05 ppb for cadmium in the sample matrix were obtained. The standard addition method was found to be reliable for the quantitative determination of the analytes in the sample. All R 2 values obtained were > 0.9900 at 95% confidence level. Validation of the established analytical methodology by analyzing certified reference standards and performing parallel analysis by GF-AAS and flame AAS showed acceptable accuracy of the DPASV measurements. (Author)

  13. Structure determination and compositional modification of body-centered tetragonal PX-phase lead titanate

    Czech Academy of Sciences Publication Activity Database

    Wang, J.; Schenk, K.; Carvalho, A.; Wylie-van Eerd, B.; Trodahl, J.; Sandu, C.S.; Bonin, M.; Gregora, Ivan; He, Z.; Yamada, T.; Funakubo, H.; Briddon, P.R.; Setter, N.

    2011-01-01

    Roč. 23, č. 10 (2011), s. 2529-2535 ISSN 0897-4756 R&D Projects: GA AV ČR KAN301370701 Institutional research plan: CEZ:AV0Z10100520 Keywords : lead titanate * fibrous PX phase * structure determination * open channels * Raman scattering Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 7.286, year: 2011

  14. Simultaneous Atomic Absorption Spectrometry for Cadmium and Lead Determination in Wastewater: A Laboratory Exercise

    Science.gov (United States)

    Correia, Paulo R. M.; Oliveira, Pedro V.

    2004-01-01

    The simultaneous determination of cadmium and lead by multi-element atomic absorption spectrometry with electrochemical atomization is proposed by employing a problem-based approach. The reports indicate that the students assimilated the principles of the simultaneous atomic absorption spectrometry (SIMAAS), the role of the chemical modifier, the…

  15. Determining lead concentration in the blood of primary school children in Damascus city and suburbs

    International Nuclear Information System (INIS)

    Al-Merey, R.; Al-Ghali, M.; Mortada, S.

    2006-01-01

    Due to the fact that lead is a relatively common element in nature and one of the most pollutant elements which man kind is exposed to in densely populated cities that have a large number of vehicles using leaded petrol which has bad effects on human health particularly children, it is found necessary to scan the health situation related to lead exposure in Damascus. The present work focuses on determining the concentration of lead in the blood of primary school children in Damascus city and some schools in the suburbs of Damascus. 546 blood samples were collected from school children in Damascus city and 183 blood samples from school children in the suburbs of Damascus. Parameters such as student's environmental, social and behavioral information were taken into consideration and correlate with lead concentration in students blood samples. Results showed that 76.3% of the samples have more than 10 μg/100 ml of lead in the blood. Which has lead to the following health effects: Decrease in hemoglobin and vitamin-D, Effects on central nervous system, Deterioration in children growth, decreasing in IQ, and kidney failure. (Authors)

  16. Determining lead concentration in the blood of primary school children in Damascus city and suburbs

    International Nuclear Information System (INIS)

    Al-Merey, R.; Galee, M.; Mortada, S.

    2005-05-01

    Due to the fact that lead is a relatively common element in nature and one of the most pollutant elements which man kind is exposed to in densely populated cities that have a large number of vehicles using leaded petrol which has bad effects on human health particularly children, it is found necessary to scan the health situation related to lead exposure in Damascus. The present work focuses on determining the concentration of lead in the blood of primary school children in Damascus city and some schools in the suburbs of Damascus. 546 blood samples were collected from school children in Damascus city and 183 blood samples from school children in the suburbs of Damascus. Parameters such as student's environmental, social and behavioral information were taken into consideration and correlate with lead concentration in students blood samples. Results showed that 76.3% of the samples have more than 10 μg/100 ml of lead in the blood. Which has lead to the following health effects: Decrease in hemoglobin and vitamin-D, Effects on central nervous system, Deterioration in children growth, decreasing in IQ, and kidney failure. (Authors)

  17. Lead isotopic characterization of respirable urban aerosols and related sources, Santiago-Chile

    International Nuclear Information System (INIS)

    Diaz, M; Kawashita, K; Antinao, J.L

    2001-01-01

    Santiago de Chile is located in a poorly ventilated valley at 33 o 30' latitude south at an altitude of 550m. Local climate is semi-arid with mean annual rainfall below 350mm. The atmospheric particles constitute one of the main factors of urban air pollution in the city. Morphological characterization of airborne particles of Santiago done by Scanning Electron Microscopy showed the presence of three groups of particles: crystalline. spherical and agglomerate particles. The crystalline shapes originated in geologic sources have perfectly defined crystallographic parameters. The agglomerated shapes are formed by organic material and submicrometrical mineral particles derived from combustion of fossil fuel and the spherical shapes are products of metallurgical activities. Some of them could been associated with the wear of motorcars. Samples of aerosols. sediments and leaded petrol of different distributors were collected. Aerosols were sampled in two sites of Santiago: the Movil monitoring station, at east of the city, and Parque O'Higgins monitoring station in downtown. These two monitoring stations belong to the MACAM network. Sediments of Mapocho, Maipo, San Francisco and Zanjon de la Aguada rivers and two samples from Disputada and Merceditas ores were studied. All the samples have been measured for their 206 Pb/ 204 Pb, 207 Pb/ 204 Pb and 208 Pb/ 204 Pb ratios. The experimental chemical procedures of sample dissolution and Pb separation by anion exchange chromatography were developed in the Sernageomin clean laboratory of Santiago de Chile. The isotopic measurements were made using a VG-Sector isotope ratio mass spectrometer fitted with a thermal ion source, multi Faraday collector and Daly collector of the Isotopic Geology Laboratory in the Universidade Federal de Rio Grande do Sul, Brazil. The measurements were corrected using NBS 981 and 982 standards. Isotopic results plotted in a 208 Pb/ 204 Pb versus 206 Pb/ 204 Pb diagram and in a 207 Pb/ 204 Pb versus

  18. Isotopically constrained lead sources in fugitive dust from unsurfaced roads in the southeast Missouri mining district

    Science.gov (United States)

    Witt, Emitt C.; Pribil, Michael; Hogan, John P; Wronkiewicz, David

    2016-01-01

    The isotopic composition of lead (Pb) in fugitive dust suspended by a vehicle from 13 unsurfaced roads in Missouri was measured to identify the source of Pb within an established long-term mining area. A three end-member model using 207Pb/206Pb and concentration as tracers resulted in fugitive dust samples plotting in the mixing field of well characterized heterogeneous end members. End members selected for this investigation include the 207Pb/206Pb for 1) a Pb-mixture representing mine tailings, 2) aerosol Pb-impacted soils within close proximity to the Buick secondary recycling smelter, and 3) an average of soils, rock cores and drill cuttings representing the background conditions. Aqua regia total concentrations and 207Pb/206Pb of mining area dust suggest that 35.4–84.3% of the source Pb in dust is associated with the mine tailings mixture, 9.1–52.7% is associated with the smelter mixture, and 0–21.6% is associated with background materials. Isotope ratios varied minimally within the operational phases of sequential extraction suggesting that mixing of all three Pb mixtures occurs throughout. Labile forms of Pb were attributed to all three end members. The extractable carbonate phase had as much as 96.6% of the total concentration associated with mine tailings, 51.8% associated with smelter deposition, and 34.2% with background. The next most labile geochemical phase (Fe + Mn Oxides) showed similar results with as much as 85.3% associated with mine tailings, 56.8% associated with smelter deposition, and 4.2% associated with the background soil.

  19. Lead determination in uranium mineralization soils by atomic absorption spectrometry with graphite oven

    International Nuclear Information System (INIS)

    Teixeira, Gleber Tacio

    2001-01-01

    The contamination of soils by lead has a great environmental importance due to its toxicity to vegetables, animals and humans. In general, the mobility of the lead is small due to its low solubility and strong adsorption in the soil. However, its solubility can be altered by several conditions (pH, redox potential and ionic stronger). Consequently, lead can migrate through the soil and can contaminate superficial and underground waters. The objective of this work was to determine the concentration of total lead in soil samples with uranium mineralization, in an area at Ipora/GO, having been evaluated as economically insuitable the extraction of that mineral. The radiogenic lead appears as a product of natural radioactive elements decay. In the decay series of uranium-238 we found the isotope lead-214 (half-life of 26,8 min), lead-210 (half-life of 22,3 min), and lead-206 that is stable. The sampling was done in profiles around north, south, east and west directions, starting from a reference point (FT), chosen by presenting the largest radiation of that place (4800 cps). A mass of 1 Kg of superficial soil was collected to each 20 m, in each profile, until 150 m of FT. Approximately, 1 g of dry soil, fraction 2 mm, was digested with a mixture of acids HNO 3 /HClO 4 2:1 (v/v), and the resulting solution was analyzed by atomic absorption. An atomic absorption spectrometer was used with graphite furnace, with deuterium arc to background correction and pyrolytic coated tube. Phosphoric acid was used as chemical modifier. The obtained results, using the standard additions method, presented a decrease of the lead concentration, in all profiles, when the distance of FT was increased. It was also made a radiometric screening in each sampling point. The lead concentration variate from 115,1 μg.g -1 in FT, to less than 40 μg.g -1 at 150 m of distance of FT ( 3 ) 2 was used. The method was applied to a certified sample, showing a good agreement between certified and

  20. Estimation of lead sources in a Japanese cedar ecosystem using stable isotope analysis

    International Nuclear Information System (INIS)

    Itoh, Yuko; Noguchi, Kyotaro; Takahashi, Masamichi; Okamoto, Toru; Yoshinaga, Shuichiro

    2007-01-01

    Anthropogenic Pb affects the environment worldwide. To understand its effect on forest ecosystem, Pb isotope ratios were determined in precipitation, various components of vegetation, the forest floor, soil and parent material in a Japanese cedar (Cryptomeria japonica D. Don) forest stand. The average 206 Pb/ 207 Pb ratio in bulk precipitation was 1.14 ± 0.01 (mean ± SD), whereas that in the subsoil (20-130 cm) was 1.18 ± 0.01. Intermediate ratios ranging from 1.15 to 1.16 were observed in the vegetation, the forest floor, and the surface soil (0-10 cm). Using the 206 Pb/ 207 Pb ratios, the contribution of anthropogenic sources to Pb accumulated in the forest were estimated by the simple binary mixing model. Sixty-two percent of the Pb in the forest floor, 71% in the vegetation, and 55% in the surface soil (0-10 cm) originated from anthropogenic sources, but only 16% in the sub-surface soil (10-20 cm) was anthropogenic. These results suggest that internal Pb cycling occurs mainly between surface soil and vegetation in a Japanese cedar ecosystem, and that anthropogenic Pb strongly influences Pb cycling. Although the Japanese cedar ecosystem has a shallow forest floor, very little atmospherically derived Pb migrated downward over 10 cm in depth

  1. Preconcentration system for cadmium and lead determination in environmental samples using polyurethane foam/Me-BTANC

    International Nuclear Information System (INIS)

    Moreira Gama, Ednilton; Silva Lima, Adriana da; Azevedo Lemos, Valfredo

    2006-01-01

    In this work, polyurethane foam (PUF) loaded with 2-(6'-methyl-2'-benzothiazolylazo)chromotropic acid (Me-BTANC) was packed in a minicolumn and it was used in an on-line preconcentration system for cadmium and lead determination. Optimum hydrodynamic and chemical conditions for metal sorption were investigated. The effects of several foreign substances on the adsorption of cadmium and lead were also reported. The enrichment factor obtained was 37 (Cd and Pb) for 180 s preconcentration time. The proposed procedures allowed the determination of metals with detection limits (3σ) of 0.80 and 3.75 μg L -1 (0.10 and 0.47 μg g -1 of solid sample) for cadmium and lead, respectively. The precision of the procedures was also calculated: 3.1 (Cd 10 μg L -1 ) and 4.4% (Pb 100 μg L -1 ). The accuracy of the procedure was checked by analysis of the certified reference materials Spinach Leaves and Fish Tissue. Cadmium and lead contents in environmental samples (black tea, spinach leaves, natural and tap water) were determined by applying the proposed procedure

  2. The influence of time on lead toxicity and bioaccumulation determined by the OECD earthworm toxicity test

    International Nuclear Information System (INIS)

    Davies, N.A.Nicola A.; Hodson, M.E.Mark E.; Black, S.Stuart

    2003-01-01

    Timing of lead addition and worms to soil affects the response of the worms to soil affects the response of the worms to lead. - Internationally agreed standard protocols for assessing chemical toxicity of contaminants in soil to worms assume that the test soil does not need to equilibrate with the chemical to be tested prior to the addition of the test organisms and that the chemical will exert any toxic effect upon the test organism within 28 days. Three experiments were carried out to investigate these assumptions. The first experiment was a standard toxicity test where lead nitrate was added to a soil in solution to give a range of concentrations. The mortality of the worms and the concentration of lead in the survivors were determined. The LC 50 s for 14 and 28 days were 5311 and 5395 μg Pb g -1 soil respectively. The second experiment was a timed lead accumulation study with worms cultivated in soil containing either 3000 or 5000 μg Pb g -1 soil . The concentration of lead in the worms was determined at various sampling times. Uptake at both concentrations was linear with time. Worms in the 5000 μg g -1 soil accumulated lead at a faster rate (3.16 μg Pb g -1 tissue day -1 ) than those in the 3000 μg g -1 soil (2.21 μg Pb g -1 tissue day -1 ). The third experiment was a timed experiment with worms cultivated in soil containing 7000 μg Pb g -1 soil . Soil and lead nitrate solution were mixed and stored at 20 deg. C. Worms were added at various times over a 35-day period. The time to death increased from 23 h, when worms were added directly after the lead was added to the soil, to 67 h when worms were added after the soil had equilibrated with the lead for 35 days. In artificially Pb-amended soils the worms accumulate Pb over the duration of their exposure to the Pb. Thus time limited toxicity tests may be terminated before worm body load has reached a toxic level. This could result in under-estimates of the toxicity of Pb to worms. As the equilibration

  3. Monte Carlo simulations and measurements for efficiency determination of lead shielded plastic scintillator detectors

    Science.gov (United States)

    Yasin, Zafar; Negoita, Florin; Tabbassum, Sana; Borcea, Ruxandra; Kisyov, Stanimir

    2017-12-01

    The plastic scintillators are used in different areas of science and technology. One of the use of these scintillator detectors is as beam loss monitors (BLM) for new generation of high intensity heavy ion in superconducting linear accelerators. Operated in pulse counting mode with rather high thresholds and shielded by few centimeters of lead in order to cope with radiofrequency noise and X-ray background emitted by accelerator cavities, they preserve high efficiency for high energy gamma ray and neutrons produced in the nuclear reactions of lost beam particles with accelerator components. Efficiency calculation and calibration of detectors is very important before their practical usage. In the present work, the efficiency of plastic scintillator detectors is simulated using FLUKA for different gamma and neutron sources like, 60Co, 137Cs and 238Pu-Be. The sources are placed at different positions around the detector. Calculated values are compared with the measured values and a reasonable agreement is observed.

  4. Determination of particulate lead during MILAGRO / MCMA-2006 using Aerosol Mass Spectrometry

    Science.gov (United States)

    Salcedo, Dara; Onasch, T. B.; Aiken, A. C.; Williams, L. R.; de Foy, B.; Cubison, M. J.; Worsnop, D. R.; Molina, L. T.; Jimenez, J. L.

    2010-05-01

    City. Pb shows a diurnal cycle with a maximum in the early morning, which is typical of primary urban pollutants. Pb shows correlation with Zn, consistent with previous studies, while the sources of Pb appear to be at least partially disjoint from those of particulate chloride. Back trajectory analysis of the T0 Pb data suggests the presence of sources inside the urban area SSW and N of T0, with different chemical forms of Pb being associated with different source locations. High signals due to particulate lead were also detected in the PEMEX site; again, no correlation between Pb and chloride plumes was observed, suggesting mostly different sources for both species.

  5. Determination of particulate lead using aerosol mass spectrometry: MILAGRO/MCMA-2006 observations

    Science.gov (United States)

    Salcedo, D.; Onasch, T. B.; Aiken, A. C.; Williams, L. R.; de Foy, B.; Cubison, M. J.; Worsnop, D. R.; Molina, L. T.; Jimenez, J. L.

    2010-06-01

    with a maximum in the early morning, which is typical of primary urban pollutants. Pb shows correlation with Zn, consistent with previous studies, while the sources of Pb appear to be at least partially disjoint from those of particulate chloride. Back trajectory analysis of the T0 Pb data suggests the presence of sources inside the urban area SSW and N of T0, with different chemical forms of Pb being associated with different source locations. High signals due to particulate lead were also detected in the PEMEX site; again, no correlation between Pb and chloride plumes was observed, suggesting mostly different sources for both species.

  6. Differential pulse anodic stripping voltametry for ultratrace determination of cadmium and lead in Antarctic snow

    International Nuclear Information System (INIS)

    Scarponi, G.; Barbante, C.; Cescon, P.

    1994-01-01

    Differential pulse anodic stripping voltametry has sufficient sensitivity to be used for direct determination of heavy metals in Antarctic snow, thus avoiding long and contamination-prone enrichment procedures. A result of particular concern to global change studies can be drawn from these preliminary data: lead concentration in Antarctic snow decreased rapidly during the 1980s from about 10-15 pg/g to 2-4 pg/g in 1991. (authors). 16 refs., 3 figs., 1 tab

  7. Determination of lead in whole blood: Comparison of the LeadCare blood lead testing system with zeeman longitudinal electrothermal atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Pineau, A.; Viallefont, A.; Fauconneau, B.; Rafael, M.; Guillard, O.

    2002-01-01

    This study compares the efficiency of blood lead level analysis by graphite furnace atomic absorption spectrometry (GFAAS) and the portable LeadCare Blood lead testing system (LCS). Recoveries of two added lead concentrations of 22 and 42 μg/dL ranged from 102.4 to 105.5% for LCS and from 96.3 to 97.2% for GFAAS. Measurement of a certified sample (Certified Danish Whole Blood) at a blood lead concentration of 26.2 μg/dL gave within- and between-run coefficients of variation which were both approximately 8% by LCS and 2% by GFAAS. Comparison of the tested method (LCS) versus GFAAS from analysis of 76 samples of blood lead collected from workers in different industrial sectors showed imperfect overall correlation (r = 0.95). The LCS is quite suitable for screening purposes, but requires the use of non-frozen blood collected less than 24 h before. Conservative threshold values should be applied when using the LCS for initial screening in the field. (orig.)

  8. Lead and cadmium in mushrooms from the vicinity of two large emission sources in Slovenia

    International Nuclear Information System (INIS)

    Petkovšek, Samar Al Sayegh; Pokorny, Boštjan

    2013-01-01

    Cd and Pb contents were determined in 699 samples of fruiting bodies of 55 mushrooms species, collected in the period 2000–2007 in the vicinity of the largest Slovenian thermal power plant (the Šalek Valley) and near an abandoned lead smelter (the Upper Meža Valley). The present study is the first regarding lead and cadmium in mushrooms from those exposed areas. Therefore, there was a significant lack of prior data. Among 55 studied mushroom species 36 species are edible and important from an ecotoxicological perspective. However, the remaining non-edible species are important for bioindication and allowed us to compare our results with other studies carried out in other polluted areas in Europe. The highest contents of Cd were found in Agaricus arvensis Schff.: Fr. (117 mg/kg dw) and Agaricus silvicola L.: Fr. (67.9 mg/kg dw), while the highest contents of Pb were found in Macrolepiota procera (Scop.) Singer (53.8 mg/kg dw) and Lycoperdon perlatum Pers. (50 mg/kg dw), respectively. Considering the high contents of both metals in fruiting bodies of edible fungi, together with FAO/WHO directives on tolerable levels of weekly intake of Pb/Cd by humans, it is evident that consumption of some mushroom species originating from both study areas may pose a significant human health risk. A. arvensis Schff.: Fr., A. silvicola L.: Fr. and Cortinarius caperatus (Pers.) Fr. originating from the Šalek Valley, and Armillaria mellea Vahl. P. Kumm., Boletus edulis Bull., L. perlatum Pers., Leccinum versipelle (Fr. and Hök) Snell, and M. procera (Scop.) Singer originating from the Upper Meža Valley should not be consumed at all. Our findings are consistent with some other studies, which emphasized that mushrooms from heavily polluted areas, such as in the vicinity of smelters, accumulate extremely high amounts of metals, and should therefore be omitted from human consumption. - Highlights: ► The Pb contents were higher in saprophytic fungi in comparison with mycorrhizal

  9. Positron annihilation lifetime spectroscopy source correction determination: A simulation study

    Energy Technology Data Exchange (ETDEWEB)

    Kanda, Gurmeet S.; Keeble, David J., E-mail: d.j.keeble@dundee.ac.uk

    2016-02-01

    Positron annihilation lifetime spectroscopy (PALS) can provide sensitive detection and identification of vacancy-related point defects in materials. These measurements are normally performed using a positron source supported, and enclosed by, a thin foil. Annihilation events from this source arrangement must be quantified and are normally subtracted from the spectrum before analysis of the material lifetime components proceeds. Here simulated PALS spectra reproducing source correction evaluation experiments have been systematically fitted and analysed using the packages PALSfit and MELT. Simulations were performed assuming a single lifetime material, and for a material with two lifetime components. Source correction terms representing a directly deposited source and various foil supported sources were added. It is shown that in principle these source terms can be extracted from suitably designed experiments, but that fitting a number of independent, nominally identical, spectra is recommended.

  10. Resting 12-lead electrocardiogram reveals high-risk sources of cardioembolism in young adult ischemic stroke.

    Science.gov (United States)

    Pirinen, Jani; Putaala, Jukka; Aro, Aapo L; Surakka, Ida; Haapaniemi, Anita; Kaste, Markku; Haapaniemi, Elena; Tatlisumak, Turgut; Lehto, Mika

    2015-11-01

    The diagnostic work-up to reveal etiology in a young ischemic stroke (IS) patient includes evaluation for high-risk source of cardioembolism (HRCE), since this subtype associates with high early recurrence rate and mortality. We investigated the association of ECG findings with a final etiologic subgroup of HRCE in a cohort of young patients with first-ever IS. The Helsinki Young Stroke Registry includes IS patients aged 15 to 49 years admitted between 1994 and 2007. Blinded to other clinical data, we analyzed a 12-lead resting ECG obtained 1-14 days after the onset of stroke symptoms in 690 patients. We then compared the ECG findings between a final diagnosis of HRCE (n=78) and other/undetermined causes (n=612). We used multivariate logistic regression to study the association between ECG parameters and HRCE. Of our cohort (63% male), 35% showed ECG abnormality, the most common being T-wave inversion (16%), left ventricular hypertrophy (14%), prolonged P-wave (13%), and prolonged QTc (12%). 3% had atrial fibrillation (AF), and 4% P-terminal force (PTF). Of the continuous parameters, longer QRS-duration, QTc, and wider QRS-T-angle independently associated with HRCE. After AF, PTF had the strongest independent association with HRCE (odds ratio=44.32, 95% confidence interval=[10.51-186.83]), followed by a QRS-T angle >110° (8.29 [3.55-19.32]), T-wave inversion (5.06, 2.54-10.05), and prolonged QTc (3.02 [1.39-6.56]). Routine ECG provides useful information for directing the work-up of a young IS patient. In addition to AF, PTF in particular showed a strong association with etiology of HRCE. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  11. Cascade of neural events leading from error commission to subsequent awareness revealed using EEG source imaging.

    Directory of Open Access Journals (Sweden)

    Monica Dhar

    Full Text Available The goal of the present study was to shed light on the respective contributions of three important action monitoring brain regions (i.e. cingulate cortex, insula, and orbitofrontal cortex during the conscious detection of response errors. To this end, fourteen healthy adults performed a speeded Go/Nogo task comprising Nogo trials of varying levels of difficulty, designed to elicit aware and unaware errors. Error awareness was indicated by participants with a second key press after the target key press. Meanwhile, electromyogram (EMG from the response hand was recorded in addition to high-density scalp electroencephalogram (EEG. In the EMG-locked grand averages, aware errors clearly elicited an error-related negativity (ERN reflecting error detection, and a later error positivity (Pe reflecting conscious error awareness. However, no Pe was recorded after unaware errors or hits. These results are in line with previous studies suggesting that error awareness is associated with generation of the Pe. Source localisation results confirmed that the posterior cingulate motor area was the main generator of the ERN. However, inverse solution results also point to the involvement of the left posterior insula during the time interval of the Pe, and hence error awareness. Moreover, consecutive to this insular activity, the right orbitofrontal cortex (OFC was activated in response to aware and unaware errors but not in response to hits, consistent with the implication of this area in the evaluation of the value of an error. These results reveal a precise sequence of activations in these three non-overlapping brain regions following error commission, enabling a progressive differentiation between aware and unaware errors as a function of time elapsed, thanks to the involvement first of interoceptive or proprioceptive processes (left insula, later leading to the detection of a breach in the prepotent response mode (right OFC.

  12. Atmospheric deposition of trace elements around point sources and human health risk assessment. I: Impact zones around a lead source

    DEFF Research Database (Denmark)

    Moseholm, L.; Larsen, Erik Huusfeldt; Andersen, B.

    1992-01-01

    The deposition of lead was monitored over 8 years in the area around a car battery factory north of Copenhagen, Denmark. The area also has heavy traffic. Deposition was measured by in-situ grown vegetables, transplant grass culture biomonitors, bulk deposition and soil samples. Three impact zones...... were identified by a multivariate statistical analysis. Within each zone, the total dietary intake of lead was estimated for adults and children as a percentage of the provisional tolerably weekly intake (PTWI), and as a result recommendation on restrictions in use of locally grown fruit and vegetables...

  13. Lead distribution and possible sources along vertical zone spectrum of typical ecosystems in the Gongga Mountain, eastern Tibetan Plateau

    Science.gov (United States)

    Luo, Ji; Tang, Ronggui; Sun, Shouqin; Yang, Dandan; She, Jia; Yang, Peijun

    2015-08-01

    A total of 383 samples from soil, plant, litterfall and precipitation in four typical ecosystems of Gongga Mountain were collected. Pb concentrations of samples were measured and analyzed. The results showed mean Pb concentrations in different soil layers were in the order of O > A > C, and mean Pb concentrations of the aboveground parts of plant was 3.60 ± 2.54 mg kg-1, with the minimum value of 0.77 mg kg-1 and the maximum value of 10.90 mg kg-1. Pb concentrations in soil's O-horizon and A-horizon showed a downward trend with increasing elevation (the determination coefficient R2 was 0.9478, 0.7918 and 0.9759 respectively). In contrast to other soil layers, the level of Pb concentrations in O-horizon (incomplete decomposition) was significantly high. Litterfall decomposition, atmospheric deposition and the unique climate could be main factors leading high Pb accumulation in soil's O-horizon. What's more, significant correlation (R2 = 0.8126, P soil's A-horizon confirms that fine roots could adsorb and accumulate Pb materials in soil. In general, the fact that Pb inputted into the typical ecosystems in the Gongga Mountain via long-range transportation and deposition of the atmosphere from external Pb sources could be confirmed by the HYSPLIT model and the ratio of CPb/CAl in plants (leaves) and CPb/CAl in litterfall. The mining activities and increasing anthropogenic activities (tourism development) could be main sources of Pb in this area. In order to better understand Pb sources and eco-risks of these typical ecosystems, litterfall decomposition characteristics, biomass of productivity of forest ecosystem, Pb isotopic tracing among air mass, twigs, leaves, litterfall and O-horizon soil in this vertical belt should also be taken into consideration.

  14. Dose rate reduction using epoxy mixed lead shielding: experimental and theoretical determination of its shielding effectiveness

    International Nuclear Information System (INIS)

    Yadav, R.K.B.; Prasad, S.K.; Babu, K.S.; Hardiya, M.R.; Ullas, O.P.

    2010-01-01

    Full text: High background radiation field exists in Water Treatment Area (WTA) of Rod Cutting Building (RCB) in Cirus due to beta, gamma contamination on its floor. The high contamination on sides of wall and on floor is primarily due to deposition of activity generated during the regeneration of old mixed bed cartridges earlier (before year 1985) and presently due to deposition of contaminants by sump overflowing, wastes generated during maintenance/servicing of circulating pumps. RCB-WTA contribution to collective dose in present situation is up to 30% of the total collective dose of Cirus. Various options such as chipping of top layer of concrete floor of a sample area, in-situ placing of slab of cement and lead shot mixture were considered. In this case the man-rem consumption was high as radiation dose rate on concrete chip was 0.4 mGy/h and air activity generated was high, that too long lived with 137 Cs-as main constituent. The dose reduction factor was 1.7. In the second option the reduction in dose rate was insignificant and in-situ pouring of concrete consumed high collective dose. Hence above two options were not acceptable. Therefore the idea of tiling the contaminated floor with prefabricated epoxy mixed lead shots was accepted from ALARA point of view. It was concluded that pre-fabricated slabs of epoxy mixed lead slab of 25 mm thickness can be laid in RCB area to achieve a dose rate reduction factor of approximately five at a height of 30 cm above floor. This will result in a reduction of Person-mSv consumption in RCB by a factor of 5-10. These slabs of different thickness were fabricated outside RCB and were tested for shielding effectiveness experimentally by using radiation source and theoretically using MCNP code. Dose reduction factor of five for a point source, obtained experimentally for epoxy mixed lead shots was very near to value obtained by theoretical simulation. An extended calculation for an area source using this MCNP model gives a

  15. Relative effects of climate and source strength on atmospheric lead concentrations in Auckland, New Zealand

    Science.gov (United States)

    Power, H. C.; de Freitas, C. R.; Hay, J. E.

    1992-06-01

    Atmospheric lead levels were examined to assess the consequences of the 46 percent reduction in the lead content of premium grade petrol in New Zealand. Since this change was implemented in July 1986 observed levels of atmospheric lead decreased by 38 percent, but all or part of this reduction may have been due to factors other than fluctuations in lead emissions, notably variations in climate. Analysis of detailed atmospheric lead, meteorological and traffic data measured contemporaneously provided insight into the atmospheric processes influencing lead levels in Auckland and formed the basis of a statistical model capable of predicting monthly lead concentrations. The model was used to predict lead levels in Auckland for the period July 1986 through to July 1989 in the absence of any reduction in the lead content of petrol. Comparison with values observed for the same period showed that all of the reduction in atmospheric lead levels since July 1986 can be attributed to the reduction in the lead content of petrol. Policy planning implications of such a finding are considered.

  16. Sources of Information as Determinants of Product and Process Innovation

    OpenAIRE

    G?mez, Jaime; Salazar, Idana; Vargas, Pilar

    2016-01-01

    In this paper we use a panel of manufacturing firms in Spain to examine the extent to which they use internal and external sources of information (customers, suppliers, competitors, consultants and universities) to generate product and process innovation. Our results show that, although internal sources are influential, external sources of information are key to achieve innovation performance. These results are in line with the open innovation literature because they show that firms that are ...

  17. Maternal nutritional status during pregnancy and surma use determine cord lead levels in Karachi, Pakistan

    International Nuclear Information System (INIS)

    Janjua, Naveed Zafar; Delzell, Elizabeth; Larson, Rodney R.; Meleth, Sreelatha; Kabagambe, Edmond K.; Kristensen, Sibylle; Sathiakumar, Nalini

    2008-01-01

    Objectives: To estimate the umbilical cord blood lead levels (BLLs) of Pakistani neonates and to identify determinants for umbilical BLLs. Methods: We conducted a cross-sectional study of mothers and infants at one of the two obstetric units of two tertiary care hospitals in Karachi during January-August 2005. Information from 540 mothers selected randomly from those registered for delivery was obtained about their pregnancy, diet, and current and past lead exposures. We collected umbilical cord blood for lead levels analyzed using graphite furnace atomic absorption spectrophotometry. We computed geometric and arithmetic means. We performed multiple linear regression analysis to identify factors associated with log-transformed umbilical cord BLLs. We also performed logistic regression analysis to identify determinants of high lead cord BLLs (≥10 μg/dl). Results: The geometric mean cord BLL of the neonates was 9.6 μg/dl; arithmetic mean (S.D.) was 10.8 μg/dl (5.7) with a median of 9.7 μg/dl and a range of 1.8-48.9 μg/dl. Women who reported intake of less than 58.5 mg of elemental iron supplement per day during pregnancy had cord BLL of 10.0 μg/dl; in comparison those women who had higher iron intake had lower cord BLL (8.4 μg/dl). Those who used surma (an eye cosmetic) daily had higher cord BLL (11.5 μg/dl) as compared to those who used it less frequently (9.4 μg/dl). In multivariable linear regression model, higher iron intake, owning a car, and being in 2nd quartile of mid-arm circumference were associated with low lead levels while father's occupation in lead-based industry was associated with significantly higher umbilical cord BLLs. There was interaction of daily surma use and ethnicity. Geometric mean BLLs were varied among surma users by ethnicity. Conclusions: Umbilical cord BLLs are high in Karachi, Pakistan, in comparison to those in developed countries such as United States. Measures are needed to reduce fetal lead exposure to prevent adverse

  18. Lead in school drinking water: Canada can and should address this important ongoing exposure source.

    Science.gov (United States)

    Barn, Prabjit; Kosatsky, Tom

    2011-01-01

    Reducing all preventable lead exposures in children should be a public health priority given that blood lead levels in children that were once considered "safe" have since been associated with important neuro-developmental deficits. Limited Canadian data indicate that school drinking water can be an important component of children's overall exposure to lead. Outside of Ontario, however, Canadian schools are not required to test for lead in water; in most of Canada, school testing is case by case, typically initiated by parental concerns. Provinces and territories are encouraged to follow Ontario's example by instituting a routine school water lead testing program in order to identify facilities where action can result in a decrease in students' exposure to lead. Testing and remediation frameworks developed by the US Environmental Protection Agency, Health Canada, and the province of Ontario provide direction to school boards and local and provincial/territorial health authorities.

  19. Lead isotope ratios in six lake sediment cores from Japan Archipelago: Historical record of trans-boundary pollution sources

    International Nuclear Information System (INIS)

    Hosono, Takahiro; Alvarez, Kelly; Kuwae, Michinobu

    2016-01-01

    Sediment cores from six lakes situated from north to south on the Japanese Archipelago were collected during 2009–2010 to investigate the hypothesis that deposition of lead (Pb) was coming from East Asia (including China, South Korea and eastern part of Russia). Accumulation rates and ages of the lake sediment were estimated by the "2"1"0Pb constant rate of supply model and "1"3"7Cs inputs to reconstruct the historical trends of Pb accumulation. Cores from four lakes located in the north and central Japan, showed clear evidence of Pb pollution with a change in the "2"0"6Pb/"2"0"7Pb and "2"0"8Pb/"2"0"7Pb ratios in the recent sediment as compared to the deeper sediment. Among the six studied lakes, significant inputs of anthropogenic lead emissions were observed at Lake Mikazuki (north Hokkaido in north Japan), Lake Chokai (north of Honshu), and Lake Mikuriga (central part of Honshu). Pb isotopic comparison of collected core sediment and previously reported data for wet precipitation and aerosols from different Asian regions indicate that, before 1900, Pb accumulated in these three lakes was not affected by trans-boundary sources. Lake Mikazuki started to receive Pb emissions from Russia in early 1900s, and during the last two decades, this lake has been affected by trans-boundary Pb pollution from northern China. Lake Chokai has received Pb pollutant from northern China since early 1900s until 2009, whereas for the Lake Mikuriga the major Pb contaminant was transported from southern China during the past 100 years. The results of our study demonstrate that Japan Archipelago has received trans-boundary Pb emissions from different parts of East Asian region depending on location, and the major source region has changed historically. - Highlights: • Historical trend of Pb pollution was recorded in six Japanese Lakes. • Pb concentration and Pb isotope ratios were determined for sediment cores. • High [Pb] and less radiogenic Pb isotope ratios were observed since

  20. Lead isotope ratios in six lake sediment cores from Japan Archipelago: Historical record of trans-boundary pollution sources

    Energy Technology Data Exchange (ETDEWEB)

    Hosono, Takahiro, E-mail: hosono@kumamoto-u.ac.jp [Priority Organization for Innovation and Excellence, Kumamoto University, 2-39-1 Kurokami, Kumamoto 860-8555 (Japan); Alvarez, Kelly [Priority Organization for Innovation and Excellence, Kumamoto University, 2-39-1 Kurokami, Kumamoto 860-8555 (Japan); Kuwae, Michinobu [Senior Research Fellow Center, Ehime University, 2-5 Bunkyo-cho, Matsuyama 790-8577 (Japan)

    2016-07-15

    Sediment cores from six lakes situated from north to south on the Japanese Archipelago were collected during 2009–2010 to investigate the hypothesis that deposition of lead (Pb) was coming from East Asia (including China, South Korea and eastern part of Russia). Accumulation rates and ages of the lake sediment were estimated by the {sup 210}Pb constant rate of supply model and {sup 137}Cs inputs to reconstruct the historical trends of Pb accumulation. Cores from four lakes located in the north and central Japan, showed clear evidence of Pb pollution with a change in the {sup 206}Pb/{sup 207}Pb and {sup 208}Pb/{sup 207}Pb ratios in the recent sediment as compared to the deeper sediment. Among the six studied lakes, significant inputs of anthropogenic lead emissions were observed at Lake Mikazuki (north Hokkaido in north Japan), Lake Chokai (north of Honshu), and Lake Mikuriga (central part of Honshu). Pb isotopic comparison of collected core sediment and previously reported data for wet precipitation and aerosols from different Asian regions indicate that, before 1900, Pb accumulated in these three lakes was not affected by trans-boundary sources. Lake Mikazuki started to receive Pb emissions from Russia in early 1900s, and during the last two decades, this lake has been affected by trans-boundary Pb pollution from northern China. Lake Chokai has received Pb pollutant from northern China since early 1900s until 2009, whereas for the Lake Mikuriga the major Pb contaminant was transported from southern China during the past 100 years. The results of our study demonstrate that Japan Archipelago has received trans-boundary Pb emissions from different parts of East Asian region depending on location, and the major source region has changed historically. - Highlights: • Historical trend of Pb pollution was recorded in six Japanese Lakes. • Pb concentration and Pb isotope ratios were determined for sediment cores. • High [Pb] and less radiogenic Pb isotope ratios

  1. Sources of Information as Determinants of Product and Process Innovation.

    Science.gov (United States)

    Gómez, Jaime; Salazar, Idana; Vargas, Pilar

    2016-01-01

    In this paper we use a panel of manufacturing firms in Spain to examine the extent to which they use internal and external sources of information (customers, suppliers, competitors, consultants and universities) to generate product and process innovation. Our results show that, although internal sources are influential, external sources of information are key to achieve innovation performance. These results are in line with the open innovation literature because they show that firms that are opening up their innovation process and that use different information sources have a greater capacity to generate innovations. We also find that the importance of external sources of information varies depending on the type of innovation (product or process) considered. To generate process innovation, firms mainly rely on suppliers while, to generate product innovation, the main contribution is from customers. The potential simultaneity between product and process innovation is also taken into consideration. We find that the generation of both types of innovation is not independent.

  2. Sources of Information as Determinants of Product and Process Innovation.

    Directory of Open Access Journals (Sweden)

    Jaime Gómez

    Full Text Available In this paper we use a panel of manufacturing firms in Spain to examine the extent to which they use internal and external sources of information (customers, suppliers, competitors, consultants and universities to generate product and process innovation. Our results show that, although internal sources are influential, external sources of information are key to achieve innovation performance. These results are in line with the open innovation literature because they show that firms that are opening up their innovation process and that use different information sources have a greater capacity to generate innovations. We also find that the importance of external sources of information varies depending on the type of innovation (product or process considered. To generate process innovation, firms mainly rely on suppliers while, to generate product innovation, the main contribution is from customers. The potential simultaneity between product and process innovation is also taken into consideration. We find that the generation of both types of innovation is not independent.

  3. Sources of Information as Determinants of Product and Process Innovation

    Science.gov (United States)

    2016-01-01

    In this paper we use a panel of manufacturing firms in Spain to examine the extent to which they use internal and external sources of information (customers, suppliers, competitors, consultants and universities) to generate product and process innovation. Our results show that, although internal sources are influential, external sources of information are key to achieve innovation performance. These results are in line with the open innovation literature because they show that firms that are opening up their innovation process and that use different information sources have a greater capacity to generate innovations. We also find that the importance of external sources of information varies depending on the type of innovation (product or process) considered. To generate process innovation, firms mainly rely on suppliers while, to generate product innovation, the main contribution is from customers. The potential simultaneity between product and process innovation is also taken into consideration. We find that the generation of both types of innovation is not independent. PMID:27035456

  4. Uncommon sources and some unsual manifestations of lead poisoning in a tropical developing country.

    Science.gov (United States)

    Rolston, David D K

    2011-12-01

    Lead-containing cooking utensils, sometimes used in South Indian homes, and indigenous medications, widely used in India and increasingly in developed countries, may be responsible for lead intoxication in adults. We report chronic lead poisoning in five adult patients. Not all patients had abdominal colic, while dramatic weight loss, depression and encephalopathy were seen. Once recognized, lead poisoning is treatable and sometimes preventable. Response to chelation therapy with agents such as calcium ethylenediaminetetraacetate (CaEDTA) is impressive, although several courses of therapy may be necessary.

  5. Application of proton-induced X-ray emission method to determination of lead content in blood

    International Nuclear Information System (INIS)

    Slominska, D.; Jarczyk, L.; Rokita, E.; Strzalkowski, A.; Losiowski, A.; Macheta, A.; Sych, M.; Moszkowicz, S.

    1979-01-01

    The proton induced X-ray emission method is applied for determination of lead content in the blood of the people exposed to contact with ethyline vapours and people working in lead-zinc works. (author)

  6. Determination of Cadmium, Lead and Zinc in Vegetables in Jaipur (India).

    Science.gov (United States)

    Kumar, Ashok; Verma, P S

    2014-01-01

    An atomic absorption spectroscopic method was used for the determination of Lead, Cadmium and Zinc in vegetables grown in and around Jaipur food stuffs irrigated with industrial waste water. Vegetable samples were collected after maturity, and analyzed, such as spinach (Spinacia oleracea), ladyfinger (Abelmoschus esulentus), pepper mint (Menthe pipereta), brinjal (Solanum melongena), coriander (Coriandrum sativum), cauliflower (Brassica oleracea), onion (Allium cepa), radish (Raphanus sativus), pointedgourd (Trichosanthes dioica), bottlegourd (Lagenaria siceraria), chilies (Capsicum annum), ribbedgourd (Luffa acutangula) and pumpkin (Curcurbites pepo). The concentration of Lead ranged between 1.40-71.06 ppm, Cadmium 0.61-34.48 ppm and Zinc 0.39-187.26 ppm in vegetable samples. The results reveal that urban consumers are at greater risk of purchasing fresh vegetables with high levels of heavy metal, beyond the permissible limits, as defined by the Indian Prevention of Food Adulteration Act, 1954 and WHO.

  7. Right ventricle/interventricular septum electrophysiological anatomy (determination of optimal right ventricular lead placement

    Directory of Open Access Journals (Sweden)

    М. В. Диденко

    2015-10-01

    Full Text Available Notwithstanding a theoretically justified lead placement into the interventricular septum (IVS, the data from the clinical trials demonstrate somewhat controversial results. One of these controversies is the absence of consolidated criteria for positioning the electrode to deliver pacing from the interventricular septum (IVS area. The study describes anatomic features of RV and IVS with respect to the cardiac conduction system, normal ventricular excitation and electrode implantation techniques for continuous pacing. A comparative study of 73 specimens of cadaver hearts was carried out by using electro-anatomic 3D mapping of the heart, X-ray examination, computer-aided tomography, morphological and morphometric investigation. It was found out that the medium part of IVS in the septomarginal trabecula zone could be considered the best for continuous pacing. The criteria for the RV lead to be implanted in this zone were determined.

  8. Determination of material and its thickness for Cs-137 gamma source shielding

    International Nuclear Information System (INIS)

    Tukiman

    2008-01-01

    Its has been determined the shielding material and its thickness necessarily conducted due to every material will have different half-thickness characteristics, and by the selection a suitable material and its thickness will be obtained. Half-thickness of any material is the ability of the material at a certain thickness to absorb any radiation intensity so that the intensity becomes half of its source. Sample materials to be used are concrete, wood, and lead with their thickness varied. From experiment data and theoretical computation can be concluded that lead is the suitable material for shielding with the value of HVT for gamma radiation 0,732 cm. For wood and concrete will give half-thickness of 11,0 cm and 3,164 cm respectively. (author)

  9. Flow injection determination of lead and cadmium in hair samples from workers exposed to welding fumes

    International Nuclear Information System (INIS)

    Cespon-Romero, R.M.; Yebra-Biurrun, M.C.

    2007-01-01

    A flow injection procedure involving continuous acid leaching for lead and cadmium determination in hair samples of persons in permanent contact with a polluted workplace environment by flame atomic absorption spectrometry is proposed. Variables such as sonication time, nature and concentration of the acid solution used as leaching solution, leaching temperature, flow-rate of the continuous manifold, leaching solution volume and hair particle size were simultaneously studied by applying a Plackett-Burman design approach. Results showed that nitric acid concentration (leaching solution), leaching temperature and sonication time were statistically significant variables (confidence interval of 95%). These last two variables were finally optimised by using a central composite design. The proposed procedure allowed the determination of cadmium and lead with limits of detection 0.1 and 1.0 μg g -1 , respectively. The accuracy of the developed procedure was evaluated by the analysis of a certified reference material (CRM 397, human hair, from the BCR). The proposed method was applied with satisfactory results to the determination of Cd and Pb in human hair samples of workers exposed to welding fumes

  10. Isotope Mixes, Corresponding Nuclear Properties and Reactor Design Implications of Naturally Occurring Lead Sources

    Science.gov (United States)

    2013-06-01

    than LBE 14,3 W/(m*K)) (data at 500 °C) + Slag formation First tests do not show slag formation in Pb + Dust formation Strongly reduced + Corrosion...12] R. S. Cannon, Jr. and A. P. Pierce, “Lead Isotope Guides For Mississippi Valley Lead- Zinc Exploration,” U.S. department of the Interior

  11. Magnitudes and sources of precipitation and dry deposition fluxes of industrial and natural leads to the North Pacific at Enewetak

    International Nuclear Information System (INIS)

    Settle, D.M.; Patterson, C.C.

    1982-01-01

    A total atmospheric PB input flux of 7 ng Pb cm - 2 yr - 1 was measured in the North Pacific Easterlies at Enewetak. Parameters used to measure this flux were ratio of dry deposition flux to precipitation flux; Pb/ 210 Pb in precipitation and seawater; 210 Pb flux; washout factor; and Pb concentrations in air, rain, and dry deposition deposits. Relations among these parameters estabilished at Enewetak were used to recompute and comfirm previous estimates of lead fluxes to the oceans (ng Pb cm - 2 yr - 1 ) at the following locations: North Altantic Westerlies, 170; North Pacific Westerlies, 50; and South Pacific Easterlies, 3. Prehistoric lead output fluxes to sediments (ng Pb cm - 2 yr - 1 ) at these locations have been previously measured and were 4 (Enewetak); 30 North Atlantic Westerlies; 3 North Pacific Westerlies; 4 South Pacific Easterlies. These data show that the rates of atmospheric imputs of lead to the oceans vary directly with variations in rates of upwind emission of industrial lead from urban complexes on land. In the North Pacific and North Atlantic, present rates of atmospheric lead inputs are 10-fold greater than prehistoric outputs. In equatorial regions, present inputs and past outputs are more nearly equal. These observations disclose the effects of intense industrial atmospheric emissions of lead in the northern hemisphere westerlies which have overwhelmed prehistoric natural fluxes of lead to the oceans. The average concentration of lead in marine air at Enewetak is 170n pg m - 3 and varies less than a factor of 2 from that mean. One to 15% of this lead comes from seaspray, while the remainder comes from sources on land. About 90% of the seaspray lead is industrial, while 80 to 99% of that originating from land sources is industrial. Concentrations of lead in rain at Enewetak range from 6 to 63 pg/g with a mean value of 28

  12. Modeling and analysis for determining optimal suppliers under stochastic lead times

    DEFF Research Database (Denmark)

    Abginehchi, Soheil; Farahani, Reza Zanjirani

    2010-01-01

    systems. The item acquisition lead times of suppliers are random variables. Backorder is allowed and shortage cost is charged based on not only per unit in shortage but also per time unit. Continuous review (s,Q) policy has been assumed. When the inventory level depletes to a reorder level, the total...... order is split among n suppliers. Since the suppliers have different characteristics, the quantity ordered to different suppliers may be different. The problem is to determine the reorder level and quantity ordered to each supplier so that the expected total cost per time unit, including ordering cost...

  13. Adsorptive stripping voltammetric determination of trace amounts of lead in environmental water samples with complicated matrix

    Directory of Open Access Journals (Sweden)

    Grabarczyk M.

    2013-04-01

    Full Text Available A sensitive, simple and fast adsorptive stripping voltammetric procedure for trace determination of lead in environmental water samples has been developed. The method is based on adsorptive accumulation of the Pb(II-cupferron complex onto a hanging mercury drop electrode, followed by the reduction of the adsorbed species by a voltammetric scan using differential pulse modulation. The interference from surface active substances was eliminated by adsorption of interferents onto an Amberlite XAD-16 resin. Optimumconditions for removing the surfactants by mixing the analysed sample with resin were evaluated. The accuracy of the method was tested by analyzing certified reference material (SPS-WW1 Waste Water.

  14. Determination of particulate lead using aerosol mass spectrometry: MILAGRO/MCMA-2006 observations

    Directory of Open Access Journals (Sweden)

    D. Salcedo

    2010-06-01

    from fast evaporation, which is likely due to the higher vapor pressure of the compounds generating PbCl+. This is consistent with the evaporation model results. Levels of particulate Pb measured at T0 were similar to previous studies in Mexico City. Pb shows a diurnal cycle with a maximum in the early morning, which is typical of primary urban pollutants. Pb shows correlation with Zn, consistent with previous studies, while the sources of Pb appear to be at least partially disjoint from those of particulate chloride. Back trajectory analysis of the T0 Pb data suggests the presence of sources inside the urban area SSW and N of T0, with different chemical forms of Pb being associated with different source locations. High signals due to particulate lead were also detected in the PEMEX site; again, no correlation between Pb and chloride plumes was observed, suggesting mostly different sources for both species.

  15. Factors determining family planning in Catalonia. Sources of inequity

    Directory of Open Access Journals (Sweden)

    Saurina Carme

    2012-07-01

    Full Text Available Abstract Introduction In recent decades, the foreign population in Spain has increased significantly, particularly for Catalonia, an autonomous region of Spain (2.90% in 2000 and 15.95% in 2010 and in particular Girona province (6.18% in 2000 and 21.55% in 2010. Several studies have shown a lower use of family planning methods by immigrants. This same trend is observed in Spain. The objective of this paper is to determine the existence of differences and possible sources of inequity in the use of family planning methods among health service users in Catalonia (Spain by sex, health status, place of birth and socioeconomic conditions. Methods Data were taken from an ad-hoc questionnaire which was compiled following a qualitative stage of individual interviews. Said questionnaire was administered to 1094 Catalan public health service users during 2007. A complete descriptive analysis was carried out for variables related to public health service users’ sociodemographic characteristics and variables indicating knowledge and use of family planning methods, and bivariate relationships were analysed by means of chi-square contrasts. Considering the use (or non-use of family planning methods as a dependent variable and a set of demographic, socioeconomic and health status variables as explanatory factors, the relationship was modelled using mixed models. Results The analysed sample is comprised of 54.3% women and 45.7% men, with 74.3% natives (or from the EU and 25.7% economic immigrants. 54.8% use some method of family planning, the condom (46.7% and the pill (28.0% being the two most frequently used methods. Statistical modelling indicates that those factors which most influence the use of family planning methods are level of education (30.59% and 39.29% more likelihood and having children over 14 (35.35% more likelihood. With regard to the origin of the user, we observe that patients from North Africa,sub. Saharan Africa and Asia are less likely to

  16. Factors determining family planning in Catalonia. Sources of inequity.

    Science.gov (United States)

    Saurina, Carme; Vall-Llosera, Laura; Saez, Marc

    2012-07-20

    In recent decades, the foreign population in Spain has increased significantly, particularly for Catalonia, an autonomous region of Spain (2.90% in 2000 and 15.95% in 2010) and in particular Girona province (6.18% in 2000 and 21.55% in 2010). Several studies have shown a lower use of family planning methods by immigrants. This same trend is observed in Spain. The objective of this paper is to determine the existence of differences and possible sources of inequity in the use of family planning methods among health service users in Catalonia (Spain) by sex, health status, place of birth and socioeconomic conditions. Data were taken from an ad-hoc questionnaire which was compiled following a qualitative stage of individual interviews. Said questionnaire was administered to 1094 Catalan public health service users during 2007. A complete descriptive analysis was carried out for variables related to public health service users' sociodemographic characteristics and variables indicating knowledge and use of family planning methods, and bivariate relationships were analysed by means of chi-square contrasts. Considering the use (or non-use) of family planning methods as a dependent variable and a set of demographic, socioeconomic and health status variables as explanatory factors, the relationship was modelled using mixed models. The analysed sample is comprised of 54.3% women and 45.7% men, with 74.3% natives (or from the EU) and 25.7% economic immigrants. 54.8% use some method of family planning, the condom (46.7%) and the pill (28.0%) being the two most frequently used methods. Statistical modelling indicates that those factors which most influence the use of family planning methods are level of education (30.59% and 39.29% more likelihood) and having children over 14 (35.35% more likelihood). With regard to the origin of the user, we observe that patients from North Africa,sub. Saharan Africa and Asia are less likely to use family planning methods (36.68%, 38.59% and 70

  17. Routine lead isotope determinations using a lead-207-lead-204 double spike: a long-term assessment of analytical precision and accuracy

    International Nuclear Information System (INIS)

    Woodhead, J.D.; McCulloch, M.T.; Volker, F.

    1995-01-01

    Lead-isotope data obtained on a multicollector mass spectrometer over a four year period using a 207 Pb- 204 Pb double spike to correct for the effects of mass discrimination, are reported. Considerable improvements in both precision and accuracy over conventional correction procedures were noted, without recourse to rigorous loading or run conditions. An external precision in 206 Pb/ 204 Pb, 207 Pb/ 204 Pb and 208 Pb/ 204 Pb ratios ± 0.003, 0.003 and 0.01 (2 x standard deviation), respectively, is routinely obtainable independent of minor variations in loading and run parameters. (author)

  18. Spices as a source of lead exposure: a market-basket survey in Sri Lanka.

    Science.gov (United States)

    Senanayake, M P; Perera, R; Liyanaarachchi, L A; Dassanayake, M P

    2013-12-01

    We performed a laboratory analysis of spices sold in Sri Lanka for lead content. Samples of curry powder, chili powder and turmeric powder from seven provinces, collected using the market basket survey method, underwent atomic absorption spectrometry. Blanks and standards were utilised for instrument calibration and measurement accuracy. The results were validated in two different laboratories. All samples were found to have lead levels below the US Food and Drug Administration's action level of 0.5 μg/g. Spices sold in Sri Lanka contain lead concentrations that are low and within the stipulated safety standards.

  19. ETAAS determination of thallium and silver from water matrix after colloidal precipitate flotation using lead(II hexamethylenedithiocarbamate

    Directory of Open Access Journals (Sweden)

    TRAJCE STAFILOV

    2001-10-01

    Full Text Available Afast method for the preconcentration of thallium and silver in nanogram quantities in fresh drinking waters (source, well, tap and waters for irrigation using colloidal precipitate flotation is described. Lead(II hexamethylenedithiocarbamate, Pb(HMDTC2 played the role of flotation collector. The experimental conditions for the successful separation of thallium and silver (mass of Pb, amount ofHMDTC-, pHof the system, induction time, type of surfactant etc. were optimized. After flotation separation from the mother liquor, the solid sublate containing traces of thallium and silver was dissolved and the analytes were determined by electrothermal atomic absorption spectrometry (ETAAS. The results of the ETAAS analysis are compared with those obtained by inductively coupled plasma-atomic emission spectrometry. The detection limit for thallium by this method is 0.027 mg/l, and for silver 0.005 microg/l.

  20. Nondestructive determination of lead, cadmium, tin, antimony, and barium in ceramic glazes by radioisotope X-ray fluorescence spectrometry

    International Nuclear Information System (INIS)

    Anderson, D.L.; Cunningham, W.C.

    1996-01-01

    Quantitation capabilities of radioisotope X-ray fluorescence spectrometry (RXRFS) for determining lead, cadmium, tin, antimony, and barium in ceramic glazes were investigated. Twenty-one air-dried glazes and 85 fired glazes on test tiles were analyzed by using 109 Cd and 57 Co excitation sources. Accurate Pb determinations, with limits of detection (LODs) of about 0.3 mg/cm 2 for 5 min counting times, were achieved by using the 75 keV Κ α1 X-ray photopeak and a Pb foil calibration procedure. Cd, Sn, Sb, and Ba concentrations were determined with LODs from about 0.5 to 1.5 mg/cm 2 . For Pb and Ba, results obtained by using absorption corrections based only on element concentrations determined by RXRFS and an iterative approach led to analytical biases of ≤4% relative to results obtained by using corrections based on known total element compositions. Biases were more severe for Cd, Sn, and Sb because lower X-ray energies were involved and sensitivities varied as a function of matrix Pb content. Pb concentrations were above LODs (1.3-40 mg/cm 2 ) in 39 of 47 fired open-quotes food-safeclose quotes glazes and in 33 of the other 38 fired glazes (0.4-39 mg/cm 2 ). 15 refs., 9 figs., 9 tabs

  1. Uranium-lead age determinations on granitic rocks from the eastern Bushveld Complex

    International Nuclear Information System (INIS)

    Faurie, J.N.

    1978-08-01

    Uranium-lead age determinations were carried out on four types of granitic rocks from the eastern Bushveld Complex. The oldest rocks in the area are gneisses and felsites - 2604 plus minus 100 m.y. old - which form the centre of the Dennilton dome. The Rooiberg felsites could not be dated directly because of the absence of zircon, however a porphyritic granite sill, which shows intrusive relations with the Rooiberg felsites, was dated at 2090 plus minus 40 m.y., an age which can also be regarded as a minimum age for the Rooiberg felsites. No reliable age could be determined for the granophyres because of the large amount of lead-loss reflected in the zircon. The majority of zircons from these granophyres showed a peculiar hieroglyphic texture, a phenomena which has not yet been recorded in literature. The samples collected from the granites gave an age of 1950 plus minus 80 m.y. and thus form part of the Nebo Granite. Attempts have been made to obtain more concordant zircon ages throughout the present study. Although some success was achieved by analysing different size fractions of a zircon population, the non-magnetic fractions gave the most promising results [af

  2. Determination of the 51Cr source strength at BNL

    International Nuclear Information System (INIS)

    Boger, J.; Hahn, R.L.; Chu, Y.Y.

    1995-11-01

    Neutron activation analysis (NAA) and γ-ray counting have been used to measure the activity of 24 samples removed from the GALLEX radioactive Cr neutrino source. In 9.86% of the disintegrations, 51 Cr decays with the emission of a 320-keV γ-ray. Counting this γ-ray provides a direct means to obtain the disintegration rates of the Cr samples. Based upon these disintegration rates, the authors obtain a strength of 63.1 ± 1.0 PBq for the entire Cr source. The Cr source activity has also been obtained through measuring the 51 V content of each sample by means of NAA. 51 V is the decay daughter for all decay modes of 51 Cr. Through neutron bombardment, radioactive 52 V is produced, which decays with the emission of a 1,434-keV γ-ray. By counting this γ-ray from NAA, they obtain a disintegration rate of 62.1 ± 1.0 PBq for the entire source. These values are consistent with all other measurements of the source strength done at other GALLEX Laboratories

  3. Leading internal and external sources of credit risk in the top South African banks

    Directory of Open Access Journals (Sweden)

    Tankiso Moloi

    2014-09-01

    Full Text Available This paper aimed at identifying the leading credit risk indicators in the South African banking context as well as the development of an integrated leading credit risk indicator model. A content analysis was used as a data extraction methodology and structural equation modelling was used as a data analysis methodology. The results obtained indicated that utilising the structural equation modelling, gross savings, and prime overdraft rates, number of judgements, business insolvencies and unemployment rates were formulated as leading economic and market (external indicators of credit risk in the South African banking context. Similarly, utilising the principal component analysis, bank asset quality, bank asset concentration as well as bank trading and hedging activities were formulated as leading bank specific (internal indicators of credit risk in the South African banking context. The Integrated Leading Credit Risk Indicator Model (ICRIM was formulated utilising the accepted leading credit risk indicators. The ICRIM parameters were benchmarked against the generally accepted fit indices such as the RMSEA, comparative fit (baseline comparison as well as the Hoelter and its results output were found to be consistent with these generally accepted fit indices

  4. Determination of disintegration rates of a 60Co point source and volume sources by the sum-peak method

    International Nuclear Information System (INIS)

    Kawano, Takao; Ebihara, Hiroshi

    1990-01-01

    The disintegration rates of 60 Co as a point source (<2 mm in diameter on a thin plastic disc) and volume sources (10-100 mL solutions in a polyethylene bottle) are determined by the sum-peak method. The sum-peak formula gives the exact disintegration rate for the point source at different positions from the detector. However, increasing the volume of the solution results in enlarged deviations from the true disintegration rate. Extended sources must be treated as an amalgam of many point sources. (author)

  5. A on-line method for the determination of lead and lead isotope ratios in fresh and saline waters by inductively coupled plasma mass spectrometry

    International Nuclear Information System (INIS)

    Halicz, Ludwik; Lam, J.W.H.; McLaren, J.W.

    1994-01-01

    A previously reported on-line ICP-MS method for the determination of lead and other trace elements in seawater has been re-examined to determine its suitability for the determination of lead isotope ratios ( 206 Pb/ 207 Pb and 207 Pb/ 208 Pb) in fresh and saline natural waters. A detection limit of 0.9 ng/1 for total lead (for a 5 ml sample) was achieved. Precision of isotope ratio data was 0.2-0.3% RSD at a Pb concentration of 1 μg/l, and was still better than 2% at concentrations of only 10-40 ng/1 in seawater certified reference materials (CRMs). For all three natural water CRMs examined, measured precision was very close to the limit predicted by counting statistics. (Author)

  6. Determination of the properties of magnetic turbulence in radio sources

    International Nuclear Information System (INIS)

    Spangler, S.R.

    1983-01-01

    We have considered the transport of polarized synchrotron radiation in a source possessing a highly irregular magnetic field, as proposed by Laing. The transport equation has been solved in a special case, relating the observable correlation functions in the Stokes parameters Q and U to the correlation functions of magnetic field and plasma density in the source. A rough application of our results to observations of the radio galaxy 3C 166 indicates that the turbulent scale length may be a few percent of the lobe size

  7. A rapid method for simultaneous determination of arsenic, cadmium and lead in drinking water by inductively coupled plasma mass spectrometry

    Directory of Open Access Journals (Sweden)

    Joshua Rey P. Torres

    Full Text Available The raw water source of drinking water in most areas in the Philippines is typically river water and in some cases groundwater. These sources are prone to elevated levels of metals and metalloids that may cause exposure of the general population when the treatment of the water is inadequate. This work presents a simple method based on EPA Method 200.8 for the determination of total concentrations of arsenic (As, cadmium (Cd and lead (Pb in drinking water using inductively coupled plasma-mass spectrometry (ICP-MS as the element-selective detector. This was applied in the determination of these elements in the water supply in Metro Manila, Philippines. The method detection limits were 0.095 μg L-1, 0.043 μg L-1, and 0.114 μg L-1 for total As, Cd and Pb, respectively.The method was validated using National Institute of Standards and Technology (NIST 1643e certified reference material for trace elements in water and determined values were 60.4 ± 0.5 μg L-1, 6.7 ± 0.1 μg L-1, and 19.6 ± 0.5 μg L-1 for As, Cd and Pb, respectively. These determined values were in good agreement with the certified values in the reference material. Analysis of actual drinking water samples showed that most samples did not exceed the limit of the Philippine drinking water standard for the elements.

  8. Targeting acetylcholinesterase: identification of chemical leads by high throughput screening, structure determination and molecular modeling.

    Directory of Open Access Journals (Sweden)

    Lotta Berg

    Full Text Available Acetylcholinesterase (AChE is an essential enzyme that terminates cholinergic transmission by rapid hydrolysis of the neurotransmitter acetylcholine. Compounds inhibiting this enzyme can be used (inter alia to treat cholinergic deficiencies (e.g. in Alzheimer's disease, but may also act as dangerous toxins (e.g. nerve agents such as sarin. Treatment of nerve agent poisoning involves use of antidotes, small molecules capable of reactivating AChE. We have screened a collection of organic molecules to assess their ability to inhibit the enzymatic activity of AChE, aiming to find lead compounds for further optimization leading to drugs with increased efficacy and/or decreased side effects. 124 inhibitors were discovered, with considerable chemical diversity regarding size, polarity, flexibility and charge distribution. An extensive structure determination campaign resulted in a set of crystal structures of protein-ligand complexes. Overall, the ligands have substantial interactions with the peripheral anionic site of AChE, and the majority form additional interactions with the catalytic site (CAS. Reproduction of the bioactive conformation of six of the ligands using molecular docking simulations required modification of the default parameter settings of the docking software. The results show that docking-assisted structure-based design of AChE inhibitors is challenging and requires crystallographic support to obtain reliable results, at least with currently available software. The complex formed between C5685 and Mus musculus AChE (C5685•mAChE is a representative structure for the general binding mode of the determined structures. The CAS binding part of C5685 could not be structurally determined due to a disordered electron density map and the developed docking protocol was used to predict the binding modes of this part of the molecule. We believe that chemical modifications of our discovered inhibitors, biochemical and biophysical

  9. Simultaneous determination of copper, lead and cadmium by cathodic adsorptive stripping voltammetry using artificial neural network

    International Nuclear Information System (INIS)

    Ensafi, Ali A.; Khayamian, T.; Benvidi, A.; Mirmomtaz, E.

    2006-01-01

    In this work, simultaneous determination of two groups of elements consisting of Pb(II)-Cd(II) and Cu(II)-Pb(II)-Cd(II) using adsorptive cathodic stripping voltammetry are described. The method is based on accumulation of these metal ions on mercury electrode using xylenol orange as a suitable complexing agent. The potential was scanned to the negative direction and the differential pulse stripping voltammograms were recorded. The instrumental and chemical factors were optimized using artificial neural network. The optimized conditions were obtained in pH of 5.5, xylenol orange concentration of 4.0 μM, accumulation potential of -0.50 V, accumulation time of 30 s, scan rate of 10 mV/s and pulse height of 70 mV. The relationship between the peak current versus concentration was linear over the range of 5.0-150.0 ng ml -1 for cadmium and 5.0-150.0 ng ml -1 for lead. The limits of detection were 0.98 and 1.18 ng ml -1 for lead and cadmium ions, respectively. In simultaneous determination of Cu(II), Pb(II) and Cd(II) there are inter-metallic interactions, which result a non-linear relationship between the peak current and the ionic concentration for each of the element. Therefore, an artificial neural network was used as the multivariate calibration method. The ANN was constructed with three neurons as the output layer for the simultaneous determination of the three elements. The constructed model was able to predict the concentration of the elements in the ranges of 1.0-50.0, 5.0-200.0 and 10.0-200.0 ng ml -1 , for Cu(II), Pb(II) and Cd(II), respectively

  10. Lead and other elements in house dust of Japanese residences – Source of lead and health risks due to metal exposure

    International Nuclear Information System (INIS)

    Yoshinaga, Jun; Yamasaki, Kumiko; Yonemura, Ayumi; Ishibashi, Yuri; Kaido, Takaya; Mizuno, Kodai; Takagi, Mai; Tanaka, Atsushi

    2014-01-01

    The levels of 25 elements in house dust collected from 100 general Japanese residences were measured. Factor analysis was applied on the multi-element data to explore source of Pb (median concentration 49.1 mg/kg) in house dust. Six factors were extracted and Pb was found to have great loading on the fifth factor with Sb and Sn, suggesting solder (Sn), and plastic and metals (Sb) may be the sources of Pb in the house dust of Japanese residences. No significant loading was found on soil-related factors indicating non-significant contribution of Pb in track-in soil. Seven heavy metals (Cd, Cu, Mo, Pb, Sb, Sn, and Zn) were found in house dust at >10 times more condensed than crustal abundance. Health risk of these elements to children via the ingestion of house dust was estimated based on the comparison with tolerable daily intake and found to be non-significant for most of the elements. - Highlights: • Multi-element analysis was carried out for house dust from households in Japan. • Factor analysis was applied on the multivariate data set. • The abundance of lead had a close relationship with antimony and tin in house dust. • Health risk of heavy metals in house dust for children was not serious. - Major source of Pb in house dust of Japanese residences was not track-in soil but unknown materials that contain Pb and Sb and/or Sn

  11. Experimental facility for determining plasma characteristics in ion sources

    International Nuclear Information System (INIS)

    Abroyan, M.A.; Kagan, Yu.M.; Kolokolov, N.B.; Lavrov, B.P.

    A facility for optical and electrical measurements of the plasma parameters in the arc plasma ion sources is described. The potentialities of the system are demonstrated on the basis of the electron concentration, the electron energy distribution function, and the radial population distribution of the excited states of hydrogen atoms in the arc plasma of the duoplasmatron. (U.S.)

  12. Lead isotopes in tap water: implications for Pb sources within a municipal water supply system

    International Nuclear Information System (INIS)

    Cheng Zhongqi; Foland, Kenneth A.

    2005-01-01

    Residential tap waters were investigated to examine the feasibility of using isotopic ratios to identify dominant sources of water Pb in the Columbus (Ohio, USA) municipal supply system. Overall, both the concentrations, which are generally low (0.1-28 μg/L), and isotopic compositions of tap water Pb show wide variations. This contrasts with the situation for a limited number of available service lines, which exhibit only a limited Pb-isotope variation but contain Pb of two very different types with one significantly more radiogenic than the other. Most tap water samples in contact with Pb service lines have Pb-isotope ratios that are different from the pipe Pb. Furthermore, the Pb isotope compositions of sequentially drawn samples in the same residence generally are similar, but those from separate residences are different, implying dominant Pb sources from domestic plumbing. A separate pilot study at two residences without Pb service lines shows isotopic similarity between water and solders in each house, further suggesting that the major Pb sources are domestic in these cases and dominated by Pb from solder joints. Although complicated by the broad range of overall Pb-isotope variations observed and limited by sample availability, the results suggest that Pb isotopes can be used effectively to constrain the sources of Pb in tap waters, especially for individual houses where multiple source candidates can be identified

  13. Physical mechanisms leading to high currents of highly charged ions in laser-driven ion sources

    International Nuclear Information System (INIS)

    Haseroth, Helmut; Hora, Heinrich; Regensburg Inst. of Tech.

    1996-01-01

    Heavy ion sources for the big accelerators, for example, the LHC, require considerably more ions per pulse during a short time than the best developed classical ion source, the electron cyclotron resonance (ECR) provides; thus an alternative ion source is needed. This can be expected from laser-produced plasmas, where dramatically new types of ion generation have been observed. Experiments with rather modest lasers have confirmed operation with one million pulses of 1 Hz, and 10 11 C 4+ ions per pulse reached 2 GeV/u in the Dubna synchrotron. We review here the complexities of laser-plasma interactions to underline the unique and extraordinary possibilities that the laser ion source offers. The complexities are elaborated with respect to keV and MeV ion generation, nonlinear (ponderomotive) forces, self-focusing, resonances and ''hot'' electrons, parametric instabilities, double-layer effects, and the few ps stochastic pulsation (stuttering). Recent experiments with the laser ion source have been analyzed to distinguish between the ps and ns interaction, and it was discovered that one mechanism of highly charged ion generation is the electron impact ionization (EII) mechanism, similar to the ECR, but with so much higher plasma densities that the required very large number of ions per pulse are produced. (author)

  14. Physical mechanisms leading to high currents of highly charged ions in laser-driven ion sources

    Energy Technology Data Exchange (ETDEWEB)

    Haseroth, Helmut [European Organization for Nuclear Research, Geneva (Switzerland); Hora, Heinrich [New South Wales Univ., Kensington, NSW (Australia)]|[Regensburg Inst. of Tech. (Germany). Anwenderzentrum

    1996-12-31

    Heavy ion sources for the big accelerators, for example, the LHC, require considerably more ions per pulse during a short time than the best developed classical ion source, the electron cyclotron resonance (ECR) provides; thus an alternative ion source is needed. This can be expected from laser-produced plasmas, where dramatically new types of ion generation have been observed. Experiments with rather modest lasers have confirmed operation with one million pulses of 1 Hz, and 10{sup 11} C{sup 4+} ions per pulse reached 2 GeV/u in the Dubna synchrotron. We review here the complexities of laser-plasma interactions to underline the unique and extraordinary possibilities that the laser ion source offers. The complexities are elaborated with respect to keV and MeV ion generation, nonlinear (ponderomotive) forces, self-focusing, resonances and ``hot`` electrons, parametric instabilities, double-layer effects, and the few ps stochastic pulsation (stuttering). Recent experiments with the laser ion source have been analyzed to distinguish between the ps and ns interaction, and it was discovered that one mechanism of highly charged ion generation is the electron impact ionization (EII) mechanism, similar to the ECR, but with so much higher plasma densities that the required very large number of ions per pulse are produced. (author).

  15. Transition of cord blood lead level, 1985-2002, in the Taipei area and its determinants after the cease of leaded gasoline use

    International Nuclear Information System (INIS)

    Hwang, Y.-H.; Ko Yi; Chiang, C.-D.; Hsu, S.-P.; Lee, Y.-H.; Yu, C.-H.; Chiou, C.-H.; Wang, J.-D.; Chuang, H.-Y.

    2004-01-01

    Lead has long been of concern for its toxicity, impairment of neurobehavioral and cognitive development, and electrophysiological deficits in children, even at levels less than 10 μg/dL. The present study was conducted to elucidate the extent of cord blood lead level decline in the Taipei area from 1985 to 2002 and to explore the factors affecting the cord blood lead level after the cease of leaded gasoline use. In the current study period of 2001-2002, 184 of 1310 newborns delivered in the Taipei Municipal Women and Children Hospital between September 2001 and August 2002 were eligible and randomly selected to participate in this study. Neither of their parents had an occupational lead exposure history. At each delivery, a sample of 5-10 mL umbilical cord blood was collected for lead determination by graphite furnace atomic absorption spectrometry. The cord blood lead level of the newborns in the current study period averaged 2.35±1.12 μg/dL. Together with the cord blood lead averages of 7.48±2.25 and 3.28±1.52 μg/dL obtained from two previous surveys conducted in 1985-1987 and 1990-1992, respectively, the cord blood lead level was significantly decreased (P<0.005). It is estimated that such a reduction in cord blood lead from 7.48 to 2.35 μg/dL for each year's cohort of 260,000 newborns in Taiwan might benefit the economics, ranging from US$8.9 billion to US$12.1 billion by improving the worker productivity. For the time period from 1985 to 2002, there were consistent transition patterns among the yearly fluctuations of air lead level, leaded gasoline consumption, lead content in gasoline, estimated lead amount emitted from the consumed leaded gasoline, and average cord blood lead levels of the three respective study periods. Additionally, every 0.1-g/L reduction in lead content in gasoline might lead to a lowering of cord blood lead level by 1.78 μg/dL. Furthermore, at low level of around 2 μg/dL, a multiple regression analysis demonstrated that

  16. Determination of lead in clay enameled by X-ray fluorescence technique in Total reflection and by Scanning Electron Microscopy

    International Nuclear Information System (INIS)

    Zarazua O, G.; Carapia M, L.

    2000-01-01

    This work has the objective of determining lead free in the glazed commercial stewing pans using the X-ray fluorescence technique in Total reflection (FRX) and the observation and semiquantitative determination of lead by Analytical Scanning Electron Microscopy (ASEM). (Author)

  17. Determination of 0.01–0.1% of samarium in 40–100 mg of lead chloride

    NARCIS (Netherlands)

    Agterdenbos, J.; Jütte, B.A.H.G.; Schuring, J.

    1971-01-01

    A method is described for the determination of 5–25 μg of samarium in about 40 mg of lead chloride, based on the removal of the lead by electrolysis and determination of the samarium by extraction with PAN and measurement of the extinction of the complex at 552 nm.

  18. Determination of source terms in a degenerate parabolic equation

    International Nuclear Information System (INIS)

    Cannarsa, P; Tort, J; Yamamoto, M

    2010-01-01

    In this paper, we prove Lipschitz stability results for inverse source problems relative to parabolic equations. We use the method introduced by Imanuvilov and Yamamoto in 1998 based on Carleman estimates. What is new here is that we study a class of one-dimensional degenerate parabolic equations. In our model, the diffusion coefficient vanishes at one extreme point of the domain. Instead of the classical Carleman estimates obtained by Fursikov and Imanuvilov for non degenerate equations, we use and extend some recent Carleman estimates for degenerate equations obtained by Cannarsa, Martinez and Vancostenoble. Finally, we obtain Lipschitz stability results in inverse source problems for our class of degenerate parabolic equations both in the case of a boundary observation and in the case of a locally distributed observation

  19. Effects of methods of attenuation correction on source parameter determination

    Science.gov (United States)

    Sonley, Eleanor; Abercrombie, Rachel E.

    We quantify the effects of using different approaches to model individual earthquake spectra. Applying different approaches can introduce significant variability in the calculated source parameters, even when applied to the same data. To compare large and small earthquake source parameters, the results of multiple studies need to be combined to extend the magnitude range, but the variability introduced by the different approaches hampers the outcome. When studies are combined, there is large uncertainty and large scatter and some systematic differences have been neglected. We model individual earthquake spectra from repeating earthquakes (M˜2) at Parkfield, CA, recorded by a borehole network. We focus on the effects of trade-offs between attenuation (Q) and corner frequency in spectral fitting and the effect of the model shape at the corner frequency on radiated energy. The trade-off between attenuation and corner frequency can increase radiated energy by up to 400% and seismic moment by up to 100%.

  20. Stable isotopes of lead and strontium as tracers of sources of airborne particulate matter in Kyrgyzstan

    Science.gov (United States)

    Central Asia is dominated by an arid climate and desert-like conditions, leading to the potential for long-range transport of desert dust within and out of the region. Of particular interest is the Aral Sea, which has receded in size largely due to water diversion. As a result, n...

  1. Calculation of spherical models of lead with a source of 14 MeV-neutrons

    International Nuclear Information System (INIS)

    Markovskij, D.V.; Borisov, A.A.

    1989-01-01

    Neutron transport calculations for spherical models of lead have been done with the one-dimensional code BLANK realizing the direct Monte Carlo method in the whole range of neutron energies and they are compared with the experimental results. 6 refs, 10 figs, 3 tabs

  2. Mylar sources for the absolute determination of activity

    International Nuclear Information System (INIS)

    Arenillas, Pablo A.

    1999-01-01

    Strong Mylar foils 2.5 μm thick are proposed as an alternative to the very fragile Vyns foils for the preparation of the radioactive sources for absolute counting. Several experiments have been carried out with β and X-ray emitters to demonstrate the suitability of this material. The results show that Mylar can replace Vyns foils even for low energy β emitters. (author)

  3. Determining Source Attenuation History to Support Closure by Natural Attenuation

    Science.gov (United States)

    2013-11-01

    restrictive and not very representative • Passes “ eyeball test” for style Source history captures the style of measured field data: Ratio of... eyeball test.” For all of the cases, the simulated and measured soil data often appeared very similar in style throughout the entire low permeability...representative metric confirmed that the modeling results demonstrated reasonable accuracy, which matches the expectations based on simple “ eyeball

  4. Determination of the concentrations of lead in raw milk in the Valley of Toluca

    International Nuclear Information System (INIS)

    Rosas Vilchis, E.

    1991-01-01

    The object of the present work, undertaken under the program of Regional and Cooperative Agreement for Nuclear Science and Technology in Latin America (ARCAL IV), was to determine the amounts of lead found in raw milk using the analytic techniques of Atomic Absorption Spectrophotometry (AAS), Inductively Coupled Plasma Atomic Emission Spectrometry (ICP-AES) and X-ray Fluorescence (FRX); so as to aid in solving problems of public health originating from elevated amounts of heavy metals in foods of animal origin. A total of thirty samples of raw milk were collected in the Valley of Toluca in Mexico, where heavy metal contaminants in the environment due to effects of rapid industrialization and urbanization, are known to have entered the food chain. The methodology, consisting in destroying organic matter in the samples by calcination, and included, in the case of AAS and ICP-AES, acid digestion. In the case of FRX, lead was extracted by ammonium 1-pyrrolidine carboditioate (APDC). The equipment to be used was calibrated and both blank and working solutions prepared in order to perform quantitative analysis. The concentrations of lead which were found in all the milk samples ranged from <0.03 to 0.31 μg/ml milk. These amounts within the maximum permissible limits, 0.5 μg/ml for all types of milk, established by the FDA. In the analysis ICP-AES gave best results as to sensitivity, precision and accuracy, followed by AAS which gave reliable results. FRX failed to detect lower limits and was, therefore, less reliable. (Author)

  5. Cell source determines the immunological impact of biomimetic nanoparticles.

    Science.gov (United States)

    Evangelopoulos, Michael; Parodi, Alessandro; Martinez, Jonathan O; Yazdi, Iman K; Cevenini, Armando; van de Ven, Anne L; Quattrocchi, Nicoletta; Boada, Christian; Taghipour, Nima; Corbo, Claudia; Brown, Brandon S; Scaria, Shilpa; Liu, Xuewu; Ferrari, Mauro; Tasciotti, Ennio

    2016-03-01

    Recently, engineering the surface of nanotherapeutics with biologics to provide them with superior biocompatibility and targeting towards pathological tissues has gained significant popularity. Although the functionalization of drug delivery vectors with cellular materials has been shown to provide synthetic particles with unique biological properties, these approaches may have undesirable immunological repercussions upon systemic administration. Herein, we comparatively analyzed unmodified multistage nanovectors and particles functionalized with murine and human leukocyte cellular membrane, dubbed Leukolike Vectors (LLV), and the immunological effects that may arise in vitro and in vivo. Previously, LLV demonstrated an avoidance of opsonization and phagocytosis, in addition to superior targeting of inflammation and prolonged circulation. In this work, we performed a comprehensive evaluation of the importance of the source of cellular membrane in increasing their systemic tolerance and minimizing an inflammatory response. Time-lapse microscopy revealed LLV developed using a cellular coating derived from a murine (i.e., syngeneic) source resulted in an active avoidance of uptake by macrophage cells. Additionally, LLV composed of a murine membrane were found to have decreased uptake in the liver with no significant effect on hepatic function. As biomimicry continues to develop, this work demonstrates the necessity to consider the source of biological material in the development of future drug delivery carriers. Copyright © 2015. Published by Elsevier Ltd.

  6. Determination of Destress Blasting Effectiveness Using Seismic Source Parameters

    Science.gov (United States)

    Wojtecki, Łukasz; Mendecki, Maciej J.; Zuberek, Wacaław M.

    2017-12-01

    Underground mining of coal seams in the Upper Silesian Coal Basin is currently performed under difficult geological and mining conditions. The mining depth, dislocations (faults and folds) and mining remnants are responsible for rockburst hazard in the highest degree. This hazard can be minimized by using active rockburst prevention, where destress blastings play an important role. Destress blastings in coal seams aim to destress the local stress concentrations. These blastings are usually performed from the longwall face to decrease the stress level ahead of the longwall. An accurate estimation of active rockburst prevention effectiveness is important during mining under disadvantageous geological and mining conditions, which affect the risk of rockburst. Seismic source parameters characterize the focus of tremor, which may be useful in estimating the destress blasting effects. Investigated destress blastings were performed in coal seam no. 507 during its longwall mining in one of the coal mines in the Upper Silesian Coal Basin under difficult geological and mining conditions. The seismic source parameters of the provoked tremors were calculated. The presented preliminary investigations enable a rapid estimation of the destress blasting effectiveness using seismic source parameters, but further analysis in other geological and mining conditions with other blasting parameters is required.

  7. Lead contents in blood samples of a children population of Mexico City related to levels of airborne lead determined by PIXE

    International Nuclear Information System (INIS)

    Uribe-Hernandez, R.; Perez-Zapata, A.J.; Flores M., J.; Aldape, F.; Hernandez-Mendez, B.

    1996-01-01

    Airborne lead has been considered for many years one of the main pollutants adversely affecting the health of human beings. Moreover, this problem becomes remarkably important in large urban areas such as Mexico City. In order to assess the influence of atmospheric airborne lead in a children population, a biological blood sampling was carried out from September 1992 to June 1993 taking 698 samples in children with ages ranging from a few weeks to thirteen years old. Lead contents in whole blood were determined using anode stripping voltammetry as analytical technique. At the same time, aerosol lead contents were determined by PIXE from samples taken twice a week (two samples per day) in a neighbour area. In 58% of the samples, lead contents in blood was found over the maximum permissible level established by the Center for Disease Control (CDC) of the U.S.A. The biological sampling was correlated to levels of airborne lead as well as children age and date of sampling. General results of these comparisons are presented. (author)

  8. Determination of lead, zinc and benzo(a)pyrene in incineration flue gas

    International Nuclear Information System (INIS)

    Han Baohua; Gao Zhuqin; Guo Qian

    2003-01-01

    An analitical method was developed for the determination of lead(Pb), zinc(Zn) and benzo(a)pyrene (BaP) in flue gas of radwaste pyroysis incinerator, respectively using Inductively Coupled Plasma-Atomic Emission Spectrometry (ICP-AES) and High Performance Liquid Chromatography (HPLC). The sample preparation and the influence of major components in back-ground were researched. Interference correction coefficient for Pb and Zn are given in this article. The recovery of Pb, Zn and BaP are all above 84.0% and the relative standard deviation (RSD) were 3.51% for Pb, 7.28% for Zn and 4.50% for BaP, respectively. It shows that this analytical method can meet the incineration processes. (authors)

  9. Leading-order determination of the gluon polarisation from semi-inclusive deep inelastic scattering data

    CERN Document Server

    Adolph, C.; Akhunzyanov, R.; Alexeev, M.G.; Alexeev, G.D.; Amoroso, A.; Andrieux, V.; Anfimov, N.V.; Anosov, V.; Augustyniak, W.; Austregesilo, A.; Azevedo, C.D.R.; Badelek, B.; Balestra, F.; Barth, J.; Beck, R.; Bedfer, Y.; Bernhard, J.; Bicker, K.; Bielert, E.R.; Birsa, R.; Bisplinghoff, J.; Bodlak, M.; Boer, M.; Bordalo, P.; Bradamante, F.; Braun, C.; Bressan, A.; Buchele, M.; Chang, W.C.; Chiosso, M.; Choi, I.; Chung, S.U.; Cicuttin, A.; Crespo, M.L.; Curiel, Q.; Dalla Torre, S.; Dasgupta, S.S.; Dasgupta, S.; Denisov, O.Yu.; Dhara, L.; Donskov, S.V.; Doshita, N.; Duic, V.; Dunnweber, W.; Dziewiecki, M.; Efremov, A.; Eversheim, P.D.; Eyrich, W.; Faessler, M.; Ferrero, A.; Finger, M.; M. Finger jr; Fischer, H.; Franco, C.; von Hohenesche, N. du Fresne; Friedrich, J.M.; Frolov, V.; Fuchey, E.; Gautheron, F.; Gavrichtchouk, O.P.; Gerassimov, S.; Giordano, F.; Gnesi, I.; Gorzellik, M.; Grabmuller, S.; Grasso, A.; Grosse Perdekamp, M.; Grube, B.; Grussenmeyer, T.; Guskov, A.; Haas, F.; Hahne, D.; von Harrach, D.; Hashimoto, R.; Heinsius, F.H.; Heitz, R.; Herrmann, F.; Hinterberger, F.; Horikawa, N.; d'Hose, N.; Hsieh, C.Y.; Huber, S.; Ishimoto, S.; Ivanov, A.; Ivanshin, Yu.; Iwata, T.; Jahn, R.; Jary, V.; Joosten, R.; Jorg, P.; Kabuss, E.; Ketzer, B.; Khaustov, G.V.; Khokhlov, Yu. A.; Kisselev, Yu.; Klein, F.; Klimaszewski, K.; Koivuniemi, J.H.; Kolosov, V.N.; Kondo, K.; Konigsmann, K.; Konorov, I.; Konstantinov, V.F.; Kotzinian, A.M.; Kouznetsov, O.M.; Kramer, M.; Kremser, P.; Krinner, F.; Kroumchtein, Z.V.; Kulinich, Y.; Kunne, F.; Kurek, K.; Kurjata, R.P.; Lednev, A.A.; Lehmann, A.; Levillain, M.; Levorato, S.; Lichtenstadt, J.; Longo, R.; Maggiora, A.; Magnon, A.; Makins, N.; Makke, N.; Mallot, G.K.; Marchand, C.; Marianski, B.; Martin, A.; Marzec, J.; J.Matou s; Matsuda, H.; Matsuda, T.; Meshcheryakov, G.V.; Meyer, W.; Michigami, T.; Mikhailov, Yu. V.; Mikhasenko, M.; Miyachi, Y.; Montuenga, P.; Nagaytsev, A.; Nerling, F.; Neyret, D.; Nikolaenko, V.I.; Novy, J.; Nowak, W.D.; Nukazuka, G.; Nunes, A.S.; Olshevsky, A.G.; Orlov, I.; Ostrick, M.; Panzieri, D.; Parsamyan, B.; Paul, S.; Peng, J.C.; Pereira, F.; M. Pe s; Peshekhonov, D.V.; Platchkov, S.; Pochodzalla, J.; Polyakov, V.A.; Pretz, J.; Quaresma, M.; Quintans, C.; Ramos, S.; Regali, C.; Reicherz, G.; Riedl, C.; Roskot, M.; Rossiyskaya, N.S.; Ryabchikov, D.I.; Rybnikov, A.; Rychter, A.; Salac, R.; Samoylenko, V.D.; Sandacz, A.; Santos, C.; Sarkar, S.; Savin, I.A.; Sawada, T.; Sbrizzai, G.; Schiavon, P.; Schmidt, K.; Schmieden, H.; Schonning, K.; Schopferer, S.; Seder, E.; Selyunin, A.; Shevchenko, O.Yu.; Silva, L.; Sinha, L.; Sirtl, S.; Slunecka, M.; Smolik, J.; Sozzi, F.; Srnka, A.; Stolarski, M.; Sulc, M.; Suzuki, H.; Szabelski, A.; Szameitat, T.; Sznajder, P.; Takekawa, S.; Tasevsky, M.; Tessaro, S.; Tessarotto, F.; Thibaud, F.; Tosello, F.; Tskhay, V.; Uhl, S.; Veloso, J.; Virius, M.; Vondra, J.; Weisrock, T.; Wilfert, M.; Wolbeek, J. ter; Zaremba, K.; Zavada, P.; Zavertyaev, M.; Zemlyanichkina, E.; Ziembicki, M.; Zink, A.

    2017-01-01

    Using a novel analysis technique, the gluon polarisation in the nucleon is re-evaluated using the longitudinal double-spin asymmetry measured in the cross section of semi-inclusive single-hadron muoproduction with photon virtuality $Q^2>1~({\\rm GeV}/c)^2$. The data were obtained by the COMPASS experiment at CERN using a 160 GeV/$c$ polarised muon beam impinging on a polarised $^6$LiD target. By analysing the full range in hadron transverse momentum $p_T$, the different $p_T$-dependences of the underlying processes are separated using a neural-network approach. In the absence of pQCD calculations at next-to-leading order in the selected kinematic domain, the gluon polarisation $\\Delta g/g$ is evaluated at leading order in pQCD at a hard scale of $\\mu^2 = \\langle Q^2\\rangle = 3(GeV=c)^2$. It is determined in three intervals of the nucleon momentum fraction carried by gluons, $x_g$, covering the range $0.04 \\!<\\! x_{ \\rm g}\\! <\\! 0.28$ . and does not exhibit a significant dependence on $x_{\\rm g}$. Average...

  10. Determination of tin, chromium, cadmium and lead in canned fruits from the Czech market

    Directory of Open Access Journals (Sweden)

    Pavel Diviš

    2017-01-01

    Full Text Available The global production of metal cans is more than 300 billion cans. Benefits of metal packaging consist mainly from the great strenght, excellent barrier properties and good thermal conductivity. The main problem of used metal packaging are the corrosion processes. The corrosion of metal container causes dissolution of tin which is used as a protective layer of the steel shell of the can and other metallic elements used in the manufacture of cans. In this work 31 samples of canned fruit was analysed and the concentration of tin, chromium, cadmium and lead was determined in fruit and in syrup using ICP-OES and ICP-MS techniques. The results showed no difference between the concentration of analysed elements in fruit and in syrup. In none of the analyzed samples the permitted maximum concentration of tin 200 mg.kg-1 was exceeded. Maximum concentration of tin was measured in canned grepfruit (59.8 ±1.9 mg.kg-1. The age of cans had no significant effect on the concentration of tin in canned fruit. The concentration of tin in fruit packaged in cans with protective layer of lacquer was significantly lower than the concentration of tin in fruit packaged in cans without protective layer of lacquer. Concentration of chromium, cadmium and lead in the analysed samples was very low at the natural levels of occurrence of these metals in fruit and it was impossible to determine unequivocally that the measured concentrations of these metals in canned fruit originate from the corrosion of can. The corrosion of the tinplate was studied using scanning electron microscopy with an energy dispersive spectrometer. By analyzing the SEM pictures and EDS spectra, critical areas of tin plate corrosion were observed. Based on the measured results it can be concluded that the consumption of fresh canned fruit is not a major problem for the inhabitants of the Czech Republic in terms of intake of potentially hazardous metals.

  11. Stable lead isotope compositions in selected coals from around the world and implications for present day aerosol source tracing

    Energy Technology Data Exchange (ETDEWEB)

    M. Diaz-Somoano; M.E. Kylander; M.A. Lopez-Anton; I. Suarez-Ruiz; M.R. Martinez-Tarazona; M. Ferrat; B. Kober; D.J. Weiss [Instituto Nacional del Carbon (INCAR-CSIC), Oviedo (Spain)

    2009-02-15

    The phasing out of leaded gasoline in many countries around the world at the end of the last millennium has resulted in a complex mixture of lead sources in the atmosphere. Recent studies suggest that coal combustion has become an important source of Pb in aerosols in urban and remote areas. Lead concentration and isotopic composition is reported for 59 coal samples representing major coal deposits worldwide in an attempt to characterize this potential source. The average concentration in these coals is 35 {mu}g Pb g{sup -1}, with the highest values in coals from Spain and Peru and the lowest in coals from Australia and North America. The {sup 206}Pb/{sup 207}Pb isotope ratios range between 1.15 and 1.24, with less radiogenic Pb in coals from Europe and Asia compared to South and North America. Comparing the Pb isotopic signatures of coals from this and previous studies with those published for Northern and Southern Hemisphere aerosols, we hypothesize that coal combustion might now be an important Pb source in China, the eastern U.S., and to some extent, in Europe but not as yet in other regions including South Africa, South America, and western U.S. This supports the notion that 'old Pb pollution' from leaded gasoline reemitted into the atmosphere or long-range transport (i.e., from China to the western U.S.) is important. Comparing the isotope ratios of the coals, the age of the deposits, and Pb isotope evolution models for the major geochemical reservoirs suggests that the lead isotope ratios (PbIC) in coals is strongly influenced by the depositional coal forming environment. 47 refs., 3 figs., 1 tab.

  12. Lead chromate detected as a source of atmospheric Pb and Cr (VI) pollution

    OpenAIRE

    Lee, Pyeong-Koo; Yu, Soonyoung; Chang, Hye Jung; Cho, Hye Young; Kang, Min-Ju; Chae, Byung-Gon

    2016-01-01

    Spherical black carbon aggregates were frequently observed in dust dry deposition in Daejeon, Korea. They were tens of micrometers in diameter and presented a mixture of black carbon and several mineral phases. Transmission electron microscopy (TEM) observations with energy-dispersive X-ray spectroscopy (EDS) and selected area diffraction pattern (SADP) analyses confirmed that the aggregates were compact and included significant amounts of lead chromate (PbCrO4). The compositions and morpholo...

  13. Consideration of Fugitive Emissions in Major Source Determinations

    Science.gov (United States)

    This document may be of assistance in applying the New Source Review (NSR) air permitting regulations including the Prevention of Significant Deterioration (PSD) requirements. This document is part of the NSR Policy and Guidance Database. Some documents in the database are a scanned or retyped version of a paper photocopy of the original. Although we have taken considerable effort to quality assure the documents, some may contain typographical errors. Contact the office that issued the document if you need a copy of the original.

  14. Northeast Hub Partners and United Salts Single Source Determination

    Science.gov (United States)

    This document may be of assistance in applying the New Source Review (NSR) air permitting regulations including the Prevention of Significant Deterioration (PSD) requirements. This document is part of the NSR Policy and Guidance Database. Some documents in the database are a scanned or retyped version of a paper photocopy of the original. Although we have taken considerable effort to quality assure the documents, some may contain typographical errors. Contact the office that issued the document if you need a copy of the original.

  15. Single Source Determination for Coors/TriGen

    Science.gov (United States)

    This document may be of assistance in applying the New Source Review (NSR) air permitting regulations including the Prevention of Significant Deterioration (PSD) requirements. This document is part of the NSR Policy and Guidance Database. Some documents in the database are a scanned or retyped version of a paper photocopy of the original. Although we have taken considerable effort to quality assure the documents, some may contain typographical errors. Contact the office that issued the document if you need a copy of the original.

  16. Determination of illuminants representing typical white light emitting diodes sources

    DEFF Research Database (Denmark)

    Jost, S.; Ngo, M.; Ferrero, A.

    2017-01-01

    is to develop LED-based illuminants that describe typical white LED products based on their Spectral Power Distributions (SPDs). Some of these new illuminants will be recommended in the update of the CIE publication 15 on colorimetry with the other typical illuminants, and among them, some could be used......Solid-state lighting (SSL) products are already in use by consumers and are rapidly gaining the lighting market. Especially, white Light Emitting Diode (LED) sources are replacing banned incandescent lamps and other lighting technologies in most general lighting applications. The aim of this work...... to complement the CIE standard illuminant A for calibration use in photometry....

  17. Determining the shape of the universe using discrete sources

    International Nuclear Information System (INIS)

    Gomero, G I

    2003-01-01

    Suppose we have identified three clusters of galaxies as being topological copies of the same object. How does this information constrain the possible models for the shape of our universe? It is shown here that, if our universe has flat spatial sections, these multiple images can be accommodated within any of the six classes of compact orientable three-dimensional flat space forms. Moreover, the discovery of two more triples of multiple images in the neighbourhood of the first one would allow the determination of the topology of the universe, and in most cases the determination of its size

  18. Proficiency testing program for the determination of total arsenic, cadmium, and lead in seawater shrimp.

    Science.gov (United States)

    Kong, Mei-Fung; Chan, Serena; Wong, Yiu-Chung

    2008-01-01

    The proficiency testing (PT) program for 97 worldwide laboratories for determining total arsenic, cadmium, and lead in seawater shrimp under the auspices of the Asia-Pacific Laboratory Accreditation Cooperation (APLAC) is discussed. The program is one of the APLAC PT series whose primary purposes are to establish mutual agreement on the equivalence of the operation of APLAC member laboratories and to take corrective actions if testing deficiencies are identified. Pooled data for Cd and Pb were normally distributed with interlaboratory variations of 21.9 and 34.8%, respectively. The corresponding consensus mean values estimated by robust statistics were in good agreement with those obtained in the homogeneity tests. However, a bimodal distribution was observed from the determination of total As, in which 14 out of 74 participants reported much smaller values (0.482-6.4 mg/kg) as compared with the mean values of 60.9 mg/kg in the homogeneity test. The use of consensus mean is known to have significant deviation from the true value in bi- or multimodal distribution. Therefore, the mode value, a better estimate of central tendency, was chosen to assess participants' performance for total As. Estimates of the overall uncertainty from participants varied in this program, and some were recommended to acquire more comprehensive exposure toward important criteria as stipulated in ISO/IEC 17025.

  19. Hybrid unscented particle filter based state-of-charge determination for lead-acid batteries

    International Nuclear Information System (INIS)

    Shen, Yanqing

    2014-01-01

    Accurate prediction of cell SOC (state of charge) is important for the safety and functional capabilities of the battery energy storage application system. This paper presents a hybrid UPF (unscented particle filter) based SOC determination combined model for batteries. To simulate the entire dynamic electrical characteristics of batteries, a novel combined state space model, which takes current as a control input and let SOC and two constructed parameters as state variables, is advanced to represent cell behavior. Besides that, an improved UPF method is used to evaluate cell SOC. Taking lead-acid batteries for example, we apply the established model for test. Results show that the evolved combined state space cell model simulates battery dynamics robustly with high accuracy and the prediction value based on the improved UPF method converges to the real SOC very quickly within the error of±2%. - Highlights: • This paper introduces a hybrid UPF based SOC determination model for batteries. • The evolved model takes SOC and two constructed parameters as state variables. • The combined state space cell model simulates battery dynamics robustly. • NLMS based method is employed to lessen search space and fasten convergence process. • Novel model converges to the real SOC robustly and quickly with fewer particles

  20. Determination of strontium and lead isotope ratios of grains using high resolution inductively coupled plasma mass spectrometer with single collector

    International Nuclear Information System (INIS)

    Shinozaki, Miyuki; Ariyama, Kaoru; Kawasaki, Akira; Hirata, Takafumi

    2010-01-01

    A method for determining strontium and lead isotope ratios of grains was developed. The samples investigated in this study were rice, barley and wheat. The samples were digested with nitric acid and hydrogen peroxide, and heated in a heating block. Strontium and lead were separated from the matrix by adding an acid digested solution into a column packed with Sr resin, which has selectivity for the absorption of strontium and lead. Strontium and lead isotope ratios were determined using a high-resolution inductively coupled plasma mass spectrometer (HR-ICP-MS) with a single collector. The intraday relative standard deviations of 87 Sr/ 86 Sr and lead isotope ratios ( 204 Pb/ 206 Pb, 207 Pb/ 206 Pb, 208 Pb/ 206 Pb) by HR-ICP-MS measurements were < 0.06% and around 0.1%, respectively. This method enabled us to determine strontium and lead isotope ratios in two days. (author)

  1. Determining Sediment Sources in the Anacostia River Watershed

    Science.gov (United States)

    Devereux, O. H.; Needelman, B. A.; Prestegaard, K. L.; Gellis, A. C.; Ritchie, J. C.

    2005-12-01

    Suspended sediment is a water-quality problem in the Chesapeake Bay. This project is designed to identify sediment sources in an urban watershed, the Northeast Branch of the Anacostia River (in Washington, D.C. and Maryland - drainage area = 188.5 km2), which delivers sediment directly to the Bay. This watershed spans two physiographic regions - the Piedmont and Coastal Plain. Bank sediment and suspended-sediment deposits were characterized using the following techniques: radionuclide (Cs-137) analysis by gamma ray spectrometry, trace-element analysis by ICP-MS, clay mineralogy by XRD, and particle-size analysis by use of a laser particle-size analyzer. Sampling of bank and suspended sediment was designed to: a) characterize tributary inputs from both Piedmont and Coastal Plain sources, and b) differentiate tributary inputs from bank erosion along the main stem of the Northeast Branch. Thirteen sample sites were chosen that represent tributary source areas of each physiographic region and the main stem where mixing occurs. Surface samples of the banks were compared to overbank deposits from a ten year storm (a proxy for the suspended sediments). Fingerprint components are selected from these data. Cesium-137 concentrations were analyzed for bank and overbank deposits for each physiographic region. No clear differences were seen between the two physiographic regions. Significant differences were observed between upland tributaries and the main stem of the Anacostia River. The average activity of Cs-137 for the tributaries was 5.4 bq/kg and the average for the main stem was 1.1 bq/kg. This suggests that there is significant erosion and storage of sediment in the tributaries. The low activity from Cs-137 in the main stem suggests a lack of storage of sediment along the main stem of the river. For the trace-element data, we focused on elements that showed significant variation among the sites. For the bank sediment, these elements include: Sr, V, Y, Ce, and Nd. For the

  2. English language YouTube videos as a source of lead poisoning-related information: a cross-sectional study.

    Science.gov (United States)

    Basch, Corey H; Jackson, Ashley M; Yin, Jingjing; Hammond, Rodney N; Adhikari, Atin; Fung, Isaac Chun-Hai

    2017-07-01

    Exposure to lead is detrimental to children's development. YouTube is a form of social media through which people may learn about lead poisoning. The aim of this cross-sectional study was to analyze the variation in lead poisoning-related YouTube contents between different video sources. The 100 most viewed lead poisoning-related videos were manually coded, among which, 50 were consumer-generated, 19 were created by health care professionals, and 31 were news. The 100 videos had a total of more than 8.9 million views, with news videos accounting for 63% of those views. The odds of mentioning what lead poisoning is, how to remove lead, and specifically mentioning the danger in ages 1-5 because of rapid growth among videos created by health care professionals were 7.28 times (Odds ratio, OR = 7.28, 95% CI, 2.09, 25.37, p = 0.002); 6.83 times (OR = 6.83, 95% CI, 2.05, 22.75, p = 0.002) and 9.14 times (OR = 9.14, CI, 2.05, 40.70, p = 0.004) that of consumer-generated videos, respectively. In this study, professional videos had more accurate information regarding lead but their videos were less likely to be viewed compared to consumer-generated videos and news videos. If professional videos about lead poisoning can attract more viewers, more people would be better informed and could possibly influence policy agendas, thereby helping communities being affected by lead exposure.

  3. Cadmium and lead determination by ICPMS: Method optimization and application in carabao milk samples

    Directory of Open Access Journals (Sweden)

    Riza A. Magbitang

    2012-06-01

    Full Text Available A method utilizing inductively coupled plasma mass spectrometry (ICPMS as the element-selective detector with microwave-assisted nitric acid digestion as the sample pre-treatment technique was developed for the simultaneous determination of cadmium (Cd and lead (Pb in milk samples. The estimated detection limits were 0.09ìg kg-1 and 0.33ìg kg-1 for Cd and Pb, respectively. The method was linear in the concentration range 0.01 to 500ìg kg-1with correlation coefficients of 0.999 for both analytes.The method was validated using certified reference material BCR 150 and the determined values for Cd and Pb were 18.24 ± 0.18 ìg kg-1 and 807.57 ± 7.07ìg kg-1, respectively. Further validation using another certified reference material, NIST 1643e, resulted in determined concentrations of 6.48 ± 0.10 ìg L-1 for Cd and 21.96 ± 0.87 ìg L-1 for Pb. These determined values agree well with the certified values in the reference materials.The method was applied to processed and raw carabao milk samples collected in Nueva Ecija, Philippines.The Cd levels determined in the samples were in the range 0.11 ± 0.07 to 5.17 ± 0.13 ìg kg-1 for the processed milk samples, and 0.11 ± 0.07 to 0.45 ± 0.09 ìg kg-1 for the raw milk samples. The concentrations of Pb were in the range 0.49 ± 0.21 to 5.82 ± 0.17 ìg kg-1 for the processed milk samples, and 0.72 ± 0.18 to 6.79 ± 0.20 ìg kg-1 for the raw milk samples.

  4. The Dietary Composition and Source of Macronutrients Determine Obesity Development

    DEFF Research Database (Denmark)

    Myrmel, Lene Secher

    The drastic worldwide increase in obesity during the last decades is accompanied with several different health disorders. The underlying mechanisms for this escalation is not clear, but certain alterations in the dietary macronutrient composition are suggested to be of importance. In addition...... fat and marine oils. To further investigate the importance of the macronutrient composition on obesity development, we have performed a series of mice experiments. Our results demonstrate that both the amount and source of macronutrients influence obesity development and related disorders. The anti...... to attenuate obesity development. The gut microbiota is less affected by alterations in protein:carbohydrate ratio and adiposity, but is altered in response to an elevated fat intake. The macronutrient composition is able to affect obesity development through direct influence on energy consuming metabolic...

  5. Method and equipment to lead a cable-like material under an irradiation source

    International Nuclear Information System (INIS)

    Riesselmann, F.J.

    1975-01-01

    When irradiating cable-like material (cable jacketed with polyethylene) which is led through an irradiation source and is thus turned and twisted, no uniform irradiation and twist changes have so far been obtained. It is suggested to twist the cable before the first circuit by about 45 0 in one direction, after turning and the second circuit, to twist by about 90 0 in the other direction and to follow with a further two circuits with twisting. A suitable cable twisting device which works with discrete clamping jaw is described in detail. (UWI) [de

  6. Leading-order determination of the gluon polarisation from semi-inclusive deep inelastic scattering data

    International Nuclear Information System (INIS)

    Adolph, C.; Braun, C.; Eyrich, W.; Lehmann, A.; Zink, A.; Aghasyan, M.; Birsa, R.; Dalla Torre, S.; Levorato, S.; Santos, C.; Sozzi, F.; Tessaro, S.; Tessarotto, F.; Akhunzyanov, R.; Alexeev, G.D.; Anfimov, N.V.; Anosov, V.; Efremov, A.; Gavrichtchouk, O.P.; Guskov, A.; Ivanshin, Yu.; Kisselev, Yu.; Kouznetsov, O.M.; Kroumchtein, Z.V.; Meshcheryakov, G.V.; Nagaytsev, A.; Olshevsky, A.G.; Orlov, I.; Peshekhonov, D.V.; Rossiyskaya, N.S.; Rybnikov, A.; Savin, I.A.; Selyunin, A.; Shevchenko, O.Yu.; Slunecka, M.; Smolik, J.; Tasevsky, M.; Zavada, P.; Zemlyanichkina, E.; Alexeev, M.G.; Amoroso, A.; Balestra, F.; Chiosso, M.; Gnesi, I.; Grasso, A.; Ivanov, A.; Kotzinian, A.M.; Longo, R.; Parsamyan, B.; Takekawa, S.; Andrieux, V.; Boer, M.; Curiel, Q.; Ferrero, A.; Fuchey, E.; Hose, N. d'; Kunne, F.; Levillain, M.; Magnon, A.; Marchand, C.; Neyret, D.; Platchkov, S.; Seder, E.; Thibaud, F.; Augustyniak, W.; Klimaszewski, K.; Kurek, K.; Marianski, B.; Sandacz, A.; Szabelski, A.; Sznajder, P.; Austregesilo, A.; Chung, S.U.; Friedrich, J.M.; Grabmueller, S.; Grube, B.; Haas, F.; Huber, S.; Kraemer, M.; Krinner, F.; Paul, S.; Uhl, S.; Azevedo, C.D.R.; Pereira, F.; Veloso, J.; Badelek, B.; Barth, J.; Hahne, D.; Klein, F.; Pretz, J.; Schmieden, H.; Beck, R.; Bisplinghoff, J.; Eversheim, P.D.; Hinterberger, F.; Jahn, R.; Joosten, R.; Ketzer, B.; Mikhasenko, M.; Bedfer, Y.; Bernhard, J.; Bicker, K.; Bielert, E.R.; Mallot, G.K.; Schoenning, K.; Bodlak, M.; Finger, M.; Finger, M. Jr.; Matousek, J.; Pesek, M.; Roskot, M.; Bordalo, P.; Franco, C.; Nunes, A.S.; Quaresma, M.; Quintans, C.; Ramos, S.; Silva, L.; Stolarski, M.; Bradamante, F.; Bressan, A.; Dasgupta, S.; Makke, N.; Martin, A.; Sbrizzai, G.; Schiavon, P.; Buechele, M.; Fischer, H.; Gorzellik, M.; Grussenmeyer, T.; Heinsius, F.H.; Herrmann, F.; Joerg, P.; Koenigsmann, K.; Kremser, P.; Nowak, W.D.; Regali, C.; Schmidt, K.; Schopferer, S.; Sirtl, S.; Szameitat, T.; Wolbeek, J. ter; Chang, W.C.; Hsieh, C.Y.; Sawada, T.; Choi, I.; Giordano, F.; Grosse Perdekamp, M.; Heitz, R.; Kulinich, Y.; Makins, N.; Montuenga, P.; Peng, J.C.; Riedl, C.; Cicuttin, A.; Crespo, M.L.; Dasgupta, S.S.; Dhara, L.; Sarkar, S.; Sinha, L.; Denisov, O.Yu.; Maggiora, A.; Panzieri, D.; Tosello, F.; Donskov, S.V.; Khaustov, G.V.; Khokhlov, Yu.A.; Kolosov, V.N.; Konstantinov, V.F.; Lednev, A.A.; Mikhailov, Yu.V.; Nikolaenko, V.I.; Polyakov, V.A.; Ryabchikov, D.I.; Samoylenko, V.D.; Doshita, N.; Hashimoto, R.; Ishimoto, S.; Iwata, T.; Kondo, K.; Matsuda, H.; Michigami, T.; Miyachi, Y.; Nukazuka, G.; Suzuki, H.; Duic, V.; Dziewiecki, M.; Kurjata, R.P.; Marzec, J.; Rychter, A.; Zaremba, K.; Ziembicki, M.; Fresne von Hohenesche, N. du; Harrach, D. von; Kabuss, E.; Nerling, F.; Ostrick, M.; Pochodzalla, J.; Weisrock, T.; Wilfert, M.

    2017-01-01

    Using a novel analysis technique, the gluon polarisation in the nucleon is re-evaluated using the longitudinal double-spin asymmetry measured in the cross section of semi-inclusive single-hadron muoproduction with photon virtuality Q"2 > 1 (GeV/c)"2. The data were obtained by the COMPASS experiment at CERN using a 160 GeV/c polarised muon beam impinging on a polarised "6LiD target. By analysing the full range in hadron transverse momentum p_T, the different p_T-dependences of the underlying processes are separated using a neural-network approach. In the absence of pQCD calculations at next-to-leading order in the selected kinematic domain, the gluon polarisation Δg/g is evaluated at leading order in pQCD at a hard scale of μ"2 = left angle Q"2 right angle = 3 (GeV/c)"2. It is determined in three intervals of the nucleon momentum fraction carried by gluons, x_g, covering the range 0.04 < x_g < 0.28 and does not exhibit a significant dependence on x_g. The average over the three intervals, left angle Δg/g right angle = 0.113 ± 0.038_(_s_t_a_t_._) ± 0.036_(_s_y_s_t_._) at left angle x_g right angle ∼ 0.10, suggests that the gluon polarisation is positive in the measured x_g range. (orig.)

  7. Leading-order determination of the gluon polarisation from semi-inclusive deep inelastic scattering data

    Energy Technology Data Exchange (ETDEWEB)

    Adolph, C.; Braun, C.; Eyrich, W.; Lehmann, A.; Zink, A. [Universitaet Erlangen-Nuernberg, Physikalisches Institut, Erlangen (Germany); Aghasyan, M.; Birsa, R.; Dalla Torre, S.; Levorato, S.; Santos, C.; Sozzi, F.; Tessaro, S.; Tessarotto, F. [INFN, Trieste (Italy); Akhunzyanov, R.; Alexeev, G.D.; Anfimov, N.V.; Anosov, V.; Efremov, A.; Gavrichtchouk, O.P.; Guskov, A.; Ivanshin, Yu.; Kisselev, Yu.; Kouznetsov, O.M.; Kroumchtein, Z.V.; Meshcheryakov, G.V.; Nagaytsev, A.; Olshevsky, A.G.; Orlov, I.; Peshekhonov, D.V.; Rossiyskaya, N.S.; Rybnikov, A.; Savin, I.A.; Selyunin, A.; Shevchenko, O.Yu.; Slunecka, M.; Smolik, J.; Tasevsky, M.; Zavada, P.; Zemlyanichkina, E. [Joint Institute for Nuclear Research, Dubna, Moscow region (Russian Federation); Alexeev, M.G. [University of Turin, Department of Physics, Turin (Italy); Amoroso, A.; Balestra, F.; Chiosso, M.; Gnesi, I.; Grasso, A.; Ivanov, A.; Kotzinian, A.M.; Longo, R.; Parsamyan, B.; Takekawa, S. [University of Turin, Department of Physics, Turin (Italy); INFN, Turin (Italy); Andrieux, V.; Boer, M.; Curiel, Q.; Ferrero, A.; Fuchey, E.; Hose, N. d' ; Kunne, F.; Levillain, M.; Magnon, A.; Marchand, C.; Neyret, D.; Platchkov, S.; Seder, E.; Thibaud, F. [CEA IRFU/SPhN Saclay, Gif-sur-Yvette (France); Augustyniak, W.; Klimaszewski, K.; Kurek, K.; Marianski, B.; Sandacz, A.; Szabelski, A.; Sznajder, P. [National Centre for Nuclear Research, Warsaw (Poland); Austregesilo, A.; Chung, S.U.; Friedrich, J.M.; Grabmueller, S.; Grube, B.; Haas, F.; Huber, S.; Kraemer, M.; Krinner, F.; Paul, S.; Uhl, S. [Technische Universitaet Muenchen, Physik Department, Garching (Germany); Azevedo, C.D.R.; Pereira, F.; Veloso, J. [University of Aveiro, Department of Physics, Aveiro (Portugal); Badelek, B. [University of Warsaw, Faculty of Physics, Warsaw (Poland); Barth, J.; Hahne, D.; Klein, F.; Pretz, J.; Schmieden, H. [Universitaet Bonn, Physikalisches Institut, Bonn (Germany); Beck, R.; Bisplinghoff, J.; Eversheim, P.D.; Hinterberger, F.; Jahn, R.; Joosten, R.; Ketzer, B.; Mikhasenko, M. [Universitaet Bonn, Helmholtz-Institut fuer Strahlen- und Kernphysik, Bonn (Germany); Bedfer, Y. [CERN, Geneva 23 (Switzerland); CEA IRFU/SPhN Saclay, Gif-sur-Yvette (France); Bernhard, J. [CERN, Geneva 23 (Switzerland); Universitaet Mainz, Institut fuer Kernphysik, Mainz (Germany); Bicker, K. [CERN, Geneva 23 (Switzerland); Technische Universitaet Muenchen, Physik Department, Garching (Germany); Bielert, E.R.; Mallot, G.K.; Schoenning, K. [CERN, Geneva 23 (Switzerland); Bodlak, M.; Finger, M.; Finger, M. Jr.; Matousek, J.; Pesek, M.; Roskot, M. [Charles University in Prague, Faculty of Mathematics and Physics, Prague (Czech Republic); Bordalo, P.; Franco, C.; Nunes, A.S.; Quaresma, M.; Quintans, C.; Ramos, S.; Silva, L.; Stolarski, M. [LIP, Lisbon (Portugal); Bradamante, F.; Bressan, A.; Dasgupta, S.; Makke, N.; Martin, A.; Sbrizzai, G.; Schiavon, P. [University of Trieste, Department of Physics, Trieste (Italy); INFN, Trieste (Italy); Buechele, M.; Fischer, H.; Gorzellik, M.; Grussenmeyer, T.; Heinsius, F.H.; Herrmann, F.; Joerg, P.; Koenigsmann, K.; Kremser, P.; Nowak, W.D.; Regali, C.; Schmidt, K.; Schopferer, S.; Sirtl, S.; Szameitat, T.; Wolbeek, J. ter [Universitaet Freiburg, Physikalisches Institut, Freiburg (Germany); Chang, W.C.; Hsieh, C.Y.; Sawada, T. [Academia Sinica, Institute of Physics, Taipei (China); Choi, I.; Giordano, F.; Grosse Perdekamp, M.; Heitz, R.; Kulinich, Y.; Makins, N.; Montuenga, P.; Peng, J.C.; Riedl, C. [University of Illinois at Urbana-Champaign, Department of Physics, Urbana, IL (United States); Cicuttin, A.; Crespo, M.L. [INFN, Trieste (Italy); Abdus Salam ICTP, Trieste (Italy); Dasgupta, S.S.; Dhara, L.; Sarkar, S.; Sinha, L. [Matrivani Institute of Experimental Research and Education, Calcutta (India); Denisov, O.Yu.; Maggiora, A.; Panzieri, D.; Tosello, F. [INFN, Turin (Italy); Donskov, S.V.; Khaustov, G.V.; Khokhlov, Yu.A.; Kolosov, V.N.; Konstantinov, V.F.; Lednev, A.A.; Mikhailov, Yu.V.; Nikolaenko, V.I.; Polyakov, V.A.; Ryabchikov, D.I.; Samoylenko, V.D. [State Scientific Center Institute for High Energy Physics of National Research Center ' Kurchatov Institute' , Protvino (Russian Federation); Doshita, N.; Hashimoto, R.; Ishimoto, S.; Iwata, T.; Kondo, K.; Matsuda, H.; Michigami, T.; Miyachi, Y.; Nukazuka, G.; Suzuki, H. [Yamagata University, Yamagata (Japan); Duic, V. [University of Trieste, Department of Physics, Trieste (Italy); Dziewiecki, M.; Kurjata, R.P.; Marzec, J.; Rychter, A.; Zaremba, K.; Ziembicki, M. [Warsaw University of Technology, Institute of Radioelectronics, Warsaw (Poland); Fresne von Hohenesche, N. du; Harrach, D. von; Kabuss, E.; Nerling, F.; Ostrick, M.; Pochodzalla, J.; Weisrock, T.; Wilfert, M. [Universitaet Mainz, Institut fuer Kernphysik, Mainz (Germany); Collaboration: COMPASS Collaboration; and others

    2017-04-15

    Using a novel analysis technique, the gluon polarisation in the nucleon is re-evaluated using the longitudinal double-spin asymmetry measured in the cross section of semi-inclusive single-hadron muoproduction with photon virtuality Q{sup 2} > 1 (GeV/c){sup 2}. The data were obtained by the COMPASS experiment at CERN using a 160 GeV/c polarised muon beam impinging on a polarised {sup 6}LiD target. By analysing the full range in hadron transverse momentum p{sub T}, the different p{sub T}-dependences of the underlying processes are separated using a neural-network approach. In the absence of pQCD calculations at next-to-leading order in the selected kinematic domain, the gluon polarisation Δg/g is evaluated at leading order in pQCD at a hard scale of μ{sup 2} = left angle Q{sup 2} right angle = 3 (GeV/c){sup 2}. It is determined in three intervals of the nucleon momentum fraction carried by gluons, x{sub g}, covering the range 0.04 < x{sub g} < 0.28 and does not exhibit a significant dependence on x{sub g}. The average over the three intervals, left angle Δg/g right angle = 0.113 ± 0.038{sub (stat.)} ± 0.036{sub (syst.)} at left angle x{sub g} right angle ∼ 0.10, suggests that the gluon polarisation is positive in the measured x{sub g} range. (orig.)

  8. Determination of the silver content in some ancient coins using an Am-Be neutron source

    International Nuclear Information System (INIS)

    Cosma, C.; Fiat, T.; Znamizovschi, V.; Daraban, L.; Morariu, V.; Boros, D.; Alicu, D.

    1985-01-01

    The silver content of 40 Roman and Greek coins was determined using neutron activation analysis. with an M-Be thermal source. The pure silver standard had a weigth and shape similar to those of the analyzed coins. A monopchannel spectrometer with a NaI(Tl), 45x40 mm scintillator crystal was used. The coins were placed at the center of the entrance window of the crystal, the maximum measuring geometry being about 2π. A VA-5-968 scintillation probe was used, placed in a VA-H-161 lead shield in order to reduce the background of the detector. The irradiation time, cooling time and measuring time were 2 min, 20 sec and 1 min correspondingly. The ratio of counting rates for the standard material and the background was 2,5. The experimental errors were about 5% for concentrations higher than 50% and increasingly higher for lower silver concentrations

  9. Automobiles: Possible sources of metals other than lead in the urban atmosphere

    International Nuclear Information System (INIS)

    Xudong Huang; Keskin, S.S.; Olmez, I.; Gordon, G.E.

    1992-01-01

    At present, due to the lack of specific marker species and reliable source composition libraries for motor vehicle emissions, it is almost impossible to predict their impact on the urban atmosphere. During the last 2 yr, the authors have been performing an extensive program to identify specific inorganic tracers for recently manufactured automobiles to create a new source composition library. Initially, they speculated on the possibility of using rare earth element (REE) emissions from the modern catalytic converters. Their preliminary studies and Japanese studies indicated a substantial release of light REE from the exhausts of unleaded gasoline-powered autos. The present study, however, has shown that although REEs are emitted, their importance as a marker is minimal. Although they have analyzed numerous samples collected from test facilities, tunnels, and ambient aerosols, they present only the results of individual motor vehicle studies. Samples were collected from the exhaust of 52 passenger cars and minivans of domestic and foreign origin. All samples collected were analyzed by instrumental neutron activation analysis (INAA). The INAA results have shown that in addition to REEs, substantial amounts of other elements (sodium, magnesium, aluminum, potassium, manganese, iron, zinc, arsenic, bromine, antimony, etc.) were also emitted

  10. Dynamic determination of equivalent CT source models for personalized dosimetry

    Directory of Open Access Journals (Sweden)

    Rosendahl Stephan

    2017-09-01

    Full Text Available With improvements in CT technology, the need for reliable patient-specific dosimetry increased in the recent years. The accuracy of Monte-Carlo simulations for absolute dose estimation is related to scanner specific information on the X-ray spectra of the scanner as well as the form filter geometries and compositions. In this work a mobile measurement setup is developed, which allows both to determine the X-ray spectra and equivalent form filter of a specific scanner from just one helical scan in less than 2 minutes.

  11. Prenatal lead exposure and relationship with maternal exposure determinants in a public maternity hospital of La Plata, Argentina.

    Science.gov (United States)

    Martins, Enrique; Varea, Ana; Apezteguía, María; González, Horacio F; Girardelli, Ana; Caro, Laura Sanchez; Lobisuto, Mario; Delgado, Griselda; Disalvo, Liliana

    2014-03-01

    Prenatal lead exposure is a health hazard that may cause cognitive development impairments and other adverse effects in children. We conducted a cross sectional study analyzing cord blood lead levels (CBLL) of newborns and their relationship with maternal determinants of lead exposure. Mothers answered a questionnaire about socio-demographic, lifestyle habits and environmental characteristics. We used Mann-Whitney's test to compare CBLL geometrical means (GM) corresponding to the presence or absence of each lead exposure determinant, and Chi square test to study the relationship between CBLL and maternal lead exposure determinants. A total of 159 newborns participated in the study. CBLL GM was 2.1 μg/dL; and 25% of the participants had a measurable CBLL (LOQ=3.3 μg/dl). Although the participants had several determinants of lead exposure, we only found a significant relationship with inside household determinants, such as presence of lead piping (p=0.026), unplastered walls (p=0.046) and peeling paint (p=0.048). Our results show that CBLL GM was similar to that reported in several studies conducted around the world. However, 25% of the participants might have some degree of risk for lead poisoning. Copyright © 2013 Elsevier B.V. All rights reserved.

  12. Resuspension of soil as a source of airborne lead near industrial facilities and highways.

    Science.gov (United States)

    Young, Thomas M; Heeraman, Deo A; Sirin, Gorkem; Ashbaugh, Lowell L

    2002-06-01

    Geologic materials are an important source of airborne particulate matter less than 10 microm aerodynamic diameter (PM10), but the contribution of contaminated soil to concentrations of Pb and other trace elements in air has not been documented. To examine the potential significance of this mechanism, surface soil samples with a range of bulk soil Pb concentrations were obtained near five industrial facilities and along roadsides and were resuspended in a specially designed laboratory chamber. The concentration of Pb and other trace elements was measured in the bulk soil, in soil size fractions, and in PM10 generated during resuspension of soils and fractions. Average yields of PM10 from dry soils ranged from 0.169 to 0.869 mg of PM10/g of soil. Yields declined approximately linearly with increasing geometric mean particle size of the bulk soil. The resulting PM10 had average Pb concentrations as high as 2283 mg/kg for samples from a secondary Pb smelter. Pb was enriched in PM10 by 5.36-88.7 times as compared with uncontaminated California soils. Total production of PM10 bound Pb from the soil samples varied between 0.012 and 1.2 mg of Pb/kg of bulk soil. During a relatively large erosion event, a contaminated site might contribute approximately 300 ng/m3 of PM10-bound Pb to air. Contribution of soil from contaminated sites to airborne element balances thus deserves consideration when constructing receptor models for source apportionment or attempting to control airborne Pb emissions.

  13. Thiopental and Phenytoin as Novel Ionophores for Potentiometric Determination of Lead (II Ions

    Directory of Open Access Journals (Sweden)

    Yasser M. Abd EL-Karem

    2009-03-01

    Full Text Available Two novel polymeric membrane sensors for the analysis of Pb(II have been developed based ontwo therapeutic drugs, thiopental (TP and phenytoin (PT as two new ionophores and potassium tetrakis(p-chlorophenyl borate (KTpClPB as a lipophilic additive, in plasticized PVC membranes. The sensors show a Nernstian response for Pb(II ions over the wide concentration ranges of 1×10-2 - 7×10-6 M and 1×10-2 - 8×10-6 M for the sensors based on thiopental and phenytoin, respectively. The proposed sensors have a fast response time and can be used for more than nine weeks without any considerable divergence in potentials. The sensors exhibit comparatively good selectivity with respect to alkaline, alkaline earth and some transition and heavy metal ions. They were employed for direct determination of lead in solder alloys and in galena rocks with a good agreement with the obtained results by atomic absorption spectroscopy.

  14. The spectrographic determination of minor and trace elements in copper, lead, and zinc concentrates

    International Nuclear Information System (INIS)

    Breckenridge, R.L.; Russell, G.M.; Watson, A.E.

    1976-01-01

    This report deals with the development of a method for the determination, by an emission-spectrographic technique, of magnesium, manganese, aluminium, silver, calcium, chromium, cobalt, titanium, antimony, cadmium, molybdenum, zirconium, nickel, boron, vanadium, arsenic, beryllium, tin, germanium, and bismuth in copper, lead, and zinc sulphide concentrates. The method involves the preparation of complex standards in which the volatile elements arsenic, antimony, cadmium, tin, and bismuth are incorporated as sulphide compounds at temperatures of 800 degrees Celsius in evacuated silica tubes together with a synthetic sulphide matrix. These standards are then mixed with the other minor and trace elements to form composite standards. The conditions for excitation with a direct-current arc, and the analytical lines for the elements and internal standards, are given. The procedure is rapid and convenient, and involves the minimum of sample preparation. The accuracy is about 10 per cent, and the method has a coefficient of variation for the various elements of between 2 and 13 per cent

  15. Radiation trapping in atomic absorption spectroscopy at lead determination in different matricies

    International Nuclear Information System (INIS)

    El-Gohary, Z.

    2005-01-01

    The determination of lead by flame atomic absorption analysis in the presence of Sn and Fe atoms and different matrices such as OH and SO 3 was investigated with the objective of understanding the spectral interference processes at the analytical lines 283.31 nm for a wide range of concentration. The radiation trapping factor was interpreted and evaluated assuming Voigt distribution of the atomic and rotational lines in the flame. The radiation trapping factor was increased by increasing the number density (plasma of the absorbing medium is optically thick). In plasma, there is a certain point of equilibrium between the trapping and the escaping of radiation, which is relevant to 50% of absorption. The spectral background interference can cause a variation of the number density at equilibrium point as a result of the degree of overlap with the analytical line. The spectral background interference can be easily avoided by using another resonance absorption line for the analysis. The chemical modification of the matrix is applied to minimize the interference effect. Nitric acid, ammonium nitrate and magnesium nitrate are most commonly recommended as matrix modifiers

  16. The Determination of Essentiality as a Leading Principle of the Formation of Integrated Reporting

    Directory of Open Access Journals (Sweden)

    Makarenko Vita Yu.

    2018-03-01

    Full Text Available The definition of essentiality as the leading principle of formation of integrated reporting is considered. The normative basis of essentiality in the context of integrated reporting is the International standard for integrated reporting. The principle of essentiality is that the integrated report should disclose information on issues that have a significant impact on an assessment of the organization’s ability to generate value in the short, medium, and long term periods. Essential for an integrated report is information that is capable of making changes to the organization’s value creation procedure. The definition of essentiality indicates that the essential information is the one that can change the order of assessment of any particular event. Therefore, insignificant for the integrated report is the information that cannot and does not bring such changes. The lack of a clear methodology for determining the essentiality, on the one hand, facilitates application of the principle of essentiality in specific conditions, and on the other — reduces the comparability of indicators of integrated reporting.

  17. Lead exposure in raptors from Japan and source identification using Pb stable isotope ratios.

    Science.gov (United States)

    Ishii, Chihiro; Nakayama, Shouta M M; Ikenaka, Yoshinori; Nakata, Hokuto; Saito, Keisuke; Watanabe, Yukiko; Mizukawa, Hazuki; Tanabe, Shinsuke; Nomiyama, Kei; Hayashi, Terutake; Ishizuka, Mayumi

    2017-11-01

    Lead (Pb) poisoning is widespread among raptors and water birds. In Japan, fragments of Pb ammunition are still found in endangered eagles although more than 10 years have passed since legislation regarding use of Pb ammunition was introduced. This study was performed to investigate Pb exposure in raptors from various locations in Japan. We measured hepatic and renal Pb concentrations and hepatic Pb isotope ratios of Steller's sea eagles (Haliaeetus pelagicus), white-tailed sea eagles (Haliaeetus albicilla), golden eagles (Aquila chrysaetos), and 13 other species (total 177 individuals) that were found dead, as well as blood samples from three eagles found in a weakened state during 1993-2015 from Hokkaido (northern part), Honshu (the main island), and Shikoku (a southern island) of Japan. In the present study in Hokkaido, one quarter of the sea eagles showed a high Pb concentration, suggesting exposure to abnormally high Pb levels and Pb poisoning. Pb isotope ratios indicated that endangered Steller's sea eagle and white-tailed sea eagle were poisoned by Pb ammunition that was used illegally in Hokkaido. In other areas of Japan, both surveillance and regulations were less extensive than in Hokkaido, but Pb poisoning in raptors was also noted. Therefore, Pb poisoning is still a serious problem in raptors in various areas of Japan due to accidental ingestion of materials containing Pb, especially Pb ammunition. Copyright © 2017. Published by Elsevier Ltd.

  18. Mesua beccariana (Clusiaceae, A Source of Potential Anti-cancer Lead Compounds in Drug Discovery

    Directory of Open Access Journals (Sweden)

    Soek Sin Teh

    2012-09-01

    Full Text Available An investigation on biologically active secondary metabolites from the stem bark of Mesua beccariana was carried out. A new cyclodione, mesuadione (1, along with several known constituents which are beccamarin (2, 2,5-dihydroxy-1,3,4-trimethoxy anthraquinone (3, 4-methoxy-1,3,5-trihydroxyanthraquinone (4, betulinic acid (5 and stigmasterol (6 were obtained from this ongoing research. Structures of these compounds were elucidated by extensive spectroscopic methods, including 1D and 2D-NMR, GC-MS, IR and UV techniques. Preliminary tests of the in vitro cytotoxic activities of all the isolated metabolites against a panel of human cancer cell lines Raji (lymphoma, SNU-1 (gastric carcinoma, K562 (erythroleukemia cells, LS-174T (colorectal adenocarcinoma, HeLa (cervical cells, SK-MEL-28 (malignant melanoma cells, NCI-H23 (lung adenocarcinoma, IMR-32 (neuroblastoma and Hep-G2 (hepatocellular liver carcinoma were carried out using an MTT assay. Mesuadione (1, beccamarin (2, betulinic acid (5 and stigmasterol (6 displayed strong inhibition of Raji cell proliferation, while the proliferation rate of SK-MEL-28 and HeLa were strongly inhibited by stigmasterol (6 and beccamarin (2, indicating these secondary metabolites could be anti-cancer lead compounds in drug discovery.

  19. Lead-acid batteries life time prolongation in renewable energy source plants

    Directory of Open Access Journals (Sweden)

    Костянтин Ігорович Ткаченко

    2015-11-01

    Full Text Available Charge controllers with microprocessor control are recognized to be almost optimal process control devices for collecting and storing energy in batteries in power systems with renewable energy sources such as solar photoelectric batteries, wind electrogenerators and others. The task of the controller is charging process control, that is such as charging and discharging the batteries while providing maximum charging speed and battery saving parameters that characterize the state of the battery, within certain limits, preventing overcharging, overheating and the batteries deep discharge. The possibility of archiving data that keeps the battery parameters time dependance is also important. Thus, the concept of a charge controller with Texas Instruments microcontroller device MSP430G2553 was introduced in the study. The program saved in the ROM microcontroller provides for: charge regime(with a particular algorithm; control and training cycle followed by charging; continuous charge-discharge regime to restore the battery or the study of charge regime algorithms influence on repair effectiveness. The device can perform its functions without being connected to a personal computer, but this connection makes it possible to observe in real time the characteristics of a number of discharge and charge regimes parameters, as well as reading the stored data from microcontroller flash memory and storing these data on the PC hard disk for further analysis. A four stages charging algorithm with reverse charging regime was offered by the author and correctness of algorithm was proved

  20. Determining the sources of fine-grained sediment using the Sediment Source Assessment Tool (Sed_SAT)

    Science.gov (United States)

    Gorman Sanisaca, Lillian E.; Gellis, Allen C.; Lorenz, David L.

    2017-07-27

    A sound understanding of sources contributing to instream sediment flux in a watershed is important when developing total maximum daily load (TMDL) management strategies designed to reduce suspended sediment in streams. Sediment fingerprinting and sediment budget approaches are two techniques that, when used jointly, can qualify and quantify the major sources of sediment in a given watershed. The sediment fingerprinting approach uses trace element concentrations from samples in known potential source areas to determine a clear signature of each potential source. A mixing model is then used to determine the relative source contribution to the target suspended sediment samples.The computational steps required to apportion sediment for each target sample are quite involved and time intensive, a problem the Sediment Source Assessment Tool (Sed_SAT) addresses. Sed_SAT is a user-friendly statistical model that guides the user through the necessary steps in order to quantify the relative contributions of sediment sources in a given watershed. The model is written using the statistical software R (R Core Team, 2016b) and utilizes Microsoft Access® as a user interface but requires no prior knowledge of R or Microsoft Access® to successfully run the model successfully. Sed_SAT identifies outliers, corrects for differences in size and organic content in the source samples relative to the target samples, evaluates the conservative behavior of tracers used in fingerprinting by applying a “Bracket Test,” identifies tracers with the highest discriminatory power, and provides robust error analysis through a Monte Carlo simulation following the mixing model. Quantifying sediment source contributions using the sediment fingerprinting approach provides local, State, and Federal land management agencies with important information needed to implement effective strategies to reduce sediment. Sed_SAT is designed to assist these agencies in applying the sediment fingerprinting

  1. Open source and healthcare in Europe - time to put leading edge ideas into practice.

    Science.gov (United States)

    Murray, Peter J; Wright, Graham; Karopka, Thomas; Betts, Helen; Orel, Andrej

    2009-01-01

    Free/Libre and Open Source Software (FLOSS) is a process of software development, a method of licensing and a philosophy. Although FLOSS plays a significant role in several market areas, the impact in the health care arena is still limited. FLOSS is promoted as one of the most effective means for overcoming fragmentation in the health care sector and providing a basis for more efficient, timely and cost effective health care provision. The 2008 European Federation for Medical Informatics (EFMI) Special Topic Conference (STC) explored a range of current and future issues related to FLOSS in healthcare (FLOSS-HC). In particular, there was a focus on health records, ubiquitous computing, knowledge sharing, and current and future applications. Discussions resulted in a list of main barriers and challenges for use of FLOSS-HC. Based on the outputs of this event, the 2004 Open Steps events and subsequent workshops at OSEHC2009 and Med-e-Tel 2009, a four-step strategy has been proposed for FLOSS-HC: 1) a FLOSS-HC inventory; 2) a FLOSS-HC collaboration platform, use case database and knowledge base; 3) a worldwide FLOSS-HC network; and 4) FLOSS-HC dissemination activities. The workshop will further refine this strategy and elaborate avenues for FLOSS-HC from scientific, business and end-user perspectives. To gain acceptance by different stakeholders in the health care industry, different activities have to be conducted in collaboration. The workshop will focus on the scientific challenges in developing methodologies and criteria to support FLOSS-HC in becoming a viable alternative to commercial and proprietary software development and deployment.

  2. Sources of anthropogenic lead in sediments from an artificial lake in Brasilia-central Brazil

    International Nuclear Information System (INIS)

    Gioia, S.M.C.L.; Pimentel, M.M.; Tessler, M.; Dantas, E.L.; Campos, J.E.G.; Guimaraes, E.M.; Maruoka, M.T.S.; Nascimento, E.L.C.

    2006-01-01

    Pb concentration and Pb isotopic composition are known to represent powerful tools to investigate the history of Pb pollution in water and sediments. In this paper, we present and discuss the results of a detailed study of sediments deposited in the Paranoa Lake, a 44-year-old artificial reservoir in Brasilia, central Brazil. Pb concentration and isotopic composition of the sediments were obtained by ID-TIMS, on three different sample fractions: leachate, residue, and bulk sample. The leachate phase has proven to be most efficient to distinguish between anthropogenic and natural Pb inputs. In the Paranoa lake, important sources of contamination were recognized, producing higher Pb concentrations (max. 37.68 ppm) and significant variations in Pb isotopic composition, relative to the regional geogenic background. Contamination of the sediments due to anthropogenic activity produced less radiogenic Pb isotopic compositions ( 206 Pb/ 207 Pb = 1.15-1.17), compared with the regional natural composition ( 206 Pb/ 207 Pb = 1.19-1.25). 21 Pb analyses along one bore hole which sampled the entire sediment section indicated a sedimentation rate of 8.2 ± 1.8 mm/year. The combined use of the 21 Pb ages and Pb isotopic compositions of these samples revealed three distinct periods in the lake history: (1) the period of the time formation of the lake in 1959 until ca. 1970 was characterized by the deposition of sediments displaying more radiogenic Pb isotopic signature, (2) the time interval from the start of the process of eutrophication at 1970, until 1995, was characterized by the deposition of sediments having less radiogenic average compositions, and (3) from 1995 until the present represents a period of recovery of water quality, after two sewage treatment stations started to operate

  3. Determination of lead levels in roadside soil and plants in Damascus city

    International Nuclear Information System (INIS)

    Othman, I; Al-Oudat, M.; Al-Masri, M.S.

    1997-04-01

    Seasonal variations of lead concentration in roadside soils and plants in 12 sites in Damascus city have been investigated. Lead concentrations in soil were found to be varied from 78.4 ppm to 832 ppm; lower levels in the wet period than in the dry period were observed. While lead levels in roadside plants varied between 3.39 ppm to 13.28 ppm. The results have also shown that most of the vegetables grown on the roadside of Damascus city have high concentrations of lead and the normal washing does not decrease it to unacceptable level. (author). 15 refs., 9 tabs

  4. Determination of mercury, lead and cadmium in water by the CRA-atomic absorption spectrophotometry with solvent extraction

    International Nuclear Information System (INIS)

    Shim, Y.B.; Won, M.S.; Kim, C.J.

    1980-01-01

    The method of CRA-atomic absorption spectrophotometer with solvent extraction for the determination of mercury, lead and cadmium in water was studied. The optimum extracting conditions for CRA-atomic absorption spectrophotometry were the following: the complexes of mercury, lead and cadmium with dithizone were separated from the aqueous solution and concentrated into the 10 ml chloroform solution. Back extraction was performed; the concentrated mercury, lead and cadmium was extracted from the chloroform solution into the 10 ml 6-normal aqueous hydrochloric acid solution. In this case, recovery ratios were the following: mercury was 94.7%, lead 97.7% and cadmium 103.6%. The optimum operating conditions for the determination of mercury, lead and cadmium by the CRA-atomic absorption spectrophotometry also were investigated to test the dry step, ash step and atomization step for each metal. The experimental results of standard addition method were the following: the determination limit of each metal within 6% relative deviation was that lead was 0.04 ppb, and cadmium 0.01 ppb. Especially, mercury has been known impossible to determine by CRA-atomic absorption spectrophotometry until now. But in this study, mercury can be determined with CRA-atomic absorption spectrophotometer. Its determination limit was 4 ppb within 8% relative deviation. (author)

  5. Determination of a source term for a time fractional diffusion equation with an integral type over-determining condition

    Directory of Open Access Journals (Sweden)

    Timurkhan S. Aleroev

    2013-12-01

    Full Text Available We consider a linear heat equation involving a fractional derivative in time, with a nonlocal boundary condition. We determine a source term independent of the space variable, and the temperature distribution for a problem with an over-determining condition of integral type. We prove the existence and uniqueness of the solution, and its continuous dependence on the data.

  6. Determination of lead, cadmium and arsenic in infusion tea cultivated in north of Iran

    Directory of Open Access Journals (Sweden)

    Shekoohiyan Sakine

    2012-12-01

    Full Text Available Abstract Tea is one of the most common drinks in all over the world. Rapid urbanization and industrialization in recent decades has increased heavy metals in tea and other foods. In this research, heavy metal contents such as lead (Pb, cadmium (Cd and arsenic (As were determined in 105 black tea samples cultivated in Guilan and Mazandaran Provinces in north of Iran and their tea infusions. The amount of heavy metals in black tea infusions were analyzed using Inductively Coupled Plasma Atomic Emission Spectroscopy (ICP - AES. The mean ± SD level of Pb in 5, 15 and 60 min in infusion tea samples were 0.802 ± 0.633, 0.993 ± 0.667 and 1.367 ± 1.06 mg/kg of tea dry weight, respectively. The mean level of Cd in 5, 15 and 60 min in infusion tea samples were 0.135 ± 0.274, 0.244 ± 0.46 and 0.343 ± 0.473 mg/kg of tea dry weight, respectively. The mean level of As in 5, 15 and 60 min in infusion tea samples were 0.277 ± 0.272, 0.426 ± 0.402 and 0.563 ± 0.454 mg/kg of tea dry weight, respectively. Also, the results showed that the locations and the infusion times influenced upon the amount of these metals (P 

  7. Nomogram for Determining Shield Thickness for Point and Line Sources of Gamma Rays

    International Nuclear Information System (INIS)

    Joenemalm, C.; Malen, K

    1966-10-01

    A set of nomograms is given for the determination of the required shield thickness against gamma radiation. The sources handled are point and infinite line sources with shields of Pb, Fe, magnetite concrete (p = 3.6), ordinary concrete (p = 2.3) or water. The gamma energy range covered is 0.5 - 10 MeV. The nomograms are directly applicable for source and dose points on the surfaces of the shield. They can easily be extended to source and dose points in other positions by applying a geometrical correction. Also included are data for calculation of the source strength for the most common materials and for fission product sources

  8. Nomogram for Determining Shield Thickness for Point and Line Sources of Gamma Rays

    Energy Technology Data Exchange (ETDEWEB)

    Joenemalm, C; Malen, K

    1966-10-15

    A set of nomograms is given for the determination of the required shield thickness against gamma radiation. The sources handled are point and infinite line sources with shields of Pb, Fe, magnetite concrete (p = 3.6), ordinary concrete (p = 2.3) or water. The gamma energy range covered is 0.5 - 10 MeV. The nomograms are directly applicable for source and dose points on the surfaces of the shield. They can easily be extended to source and dose points in other positions by applying a geometrical correction. Also included are data for calculation of the source strength for the most common materials and for fission product sources.

  9. The evaluation of an open source online training system for teaching 12 lead electrocardiographic interpretation.

    Science.gov (United States)

    Breen, Cathal; Zhu, Tingting; Bond, Raymond; Finlay, Dewar; Clifford, Gari

    2016-01-01

    The aim of this study is to present and evaluate the integration of a low resource JavaScript based ECG training interface (CrowdLabel) and a standardised curriculum for self-guided tuition in ECG interpretation. Participants practiced interpreting ECGs weekly using the CrowdLabel interface to assist with the learning of the traditional didactic taught course material during a 6 week training period. To determine competency students were tested during week 7. A total of 245 unique ECG cases were submitted by each student. Accuracy scores during the training period ranged from 0-59.5% (median = 33.3%). Conversely accuracy scores during the test ranged from 30 - 70% (median = 37.5%) (p < 0.05). There was no correlation between students who interpreted high numbers of ECGs during the training period and their marks obtained. CrowdLabel is shown to be a readily accessible dedicated learning platform to support ECG interpretation competency. Copyright © 2016 Elsevier Inc. All rights reserved.

  10. Determination of ring correction factors for leaded gloves used in grab sampling activities at Hanford tank farms

    Energy Technology Data Exchange (ETDEWEB)

    RATHBONE, B.A.

    1999-06-24

    This study evaluates the effectiveness of lead lined gloves in reducing extremity dose from two sources specific to tank waste sampling activities: (1) sludge inside glass sample jars and (2) sludge as thin layer contamination on the exterior surface of sample jars. The response of past and present Hanford Extremity Dosimeters (ring) designs under these conditions is also evaluated.

  11. Determination of ring correction factors for leaded gloves used in grab sampling activities at Hanford tank farms

    International Nuclear Information System (INIS)

    RATHBONE, B.A.

    1999-01-01

    This study evaluates the effectiveness of lead lined gloves in reducing extremity dose from two sources specific to tank waste sampling activities: (1) sludge inside glass sample jars and (2) sludge as thin layer contamination on the exterior surface of sample jars. The response of past and present Hanford Extremity Dosimeters (ring) designs under these conditions is also evaluated

  12. Lead Isotopic Compositions of Selected Coals, Pb/Zn Ores and Fuels in China and the Application for Source Tracing.

    Science.gov (United States)

    Bi, Xiang-Yang; Li, Zhong-Gen; Wang, Shu-Xiao; Zhang, Lei; Xu, Rui; Liu, Jin-Ling; Yang, Hong-Mei; Guo, Ming-Zhi

    2017-11-21

    Lead (Pb) pollution emission from China is becoming a potential worldwide threat. Pb isotopic composition analysis is a useful tool to accurately trace the Pb sources of aerosols in atmosphere. In this study, a comprehensive data set of Pb isotopes for coals, Pb/Zn ores, and fuels from China was presented. The ratios of 206 Pb/ 207 Pb and 208 Pb/ 206 Pb in the coals were in the range of 1.114-1.383 and 1.791-2.317, similar to those from Europe, Oceania, and South Asia, but different from those from America (p fuels from in coals. Urban aerosols demonstrated similar Pb isotopic compositions to coals, Pb/Zn ores, and fuels in China. After removing the leaded gasoline, the Pb in aerosols is more radiogenic, supporting the heavy contribution of coal combustion to the atmospheric Pb pollution.

  13. An experimental investigation of the shear-layer and acoustic sources produced by a leading edge slat

    Science.gov (United States)

    Wilkins, Stephen; Richard, Patrick; Hall, Joseph; Turbulence; Flow Noise Laboratory Team

    2013-11-01

    Leading edge slats are a common addition to airfoils as part of a high lift configuration employed during take-off and landing; the unsteady flow caused by these slats is a major contributor to the overal airframe noise. As the next generation of aircraft seeks to reduce these noise concerns, a better understanding of the sources of aeroacoustic noise generation is sought. Particle Image Velocimetry (PIV) and simultaneous multipoint measurements of the unsteady surface pressure are used herein to investigate the unsteady flow around a leading edge slat coupled with an airfoil for several different configurations and a range of Reynolds numbers (Re = 156 , 000 to Re = 1 . 2 million based on the wing chord). Shear-layer development off the slat cusp and the related unsteady vortex structures are examined in detail to better establish and understand the mechanisms responsible for the generation of aeroacoustic slat noise. The authors are grateful for the support provided by GARDN.

  14. Source and impact of lead contamination on δ-aminolevulinic acid dehydratase activity in several marine bivalve species along the Gulf of Cadiz

    International Nuclear Information System (INIS)

    Company, R.; Serafim, A.; Lopes, B.; Cravo, A.; Kalman, J.; Riba, I.; DelValls, T.A.; Blasco, J.; Delgado, J.; Sarmiento, A.M.; Nieto, J.M.; Shepherd, T.J.; Nowell, G.; Bebianno, M.J.

    2011-01-01

    Coastal areas and estuaries are particularly sensitive to metal contamination from anthropogenic sources and in the last few decades the study of space-time distribution and variation of metals has been extensively researched. The Gulf of Cadiz is no exception, with several rivers draining one of the largest concentrations of sulphide deposits in the world, the Iberian Pyrite Belt (IPB). Of these rivers, the Guadiana, one of the most important in the Iberian Peninsula, together with smaller rivers like the Tinto and Odiel, delivers a very high metal load to the adjacent coastal areas. The purpose of this work was to study the source and impact of lead (Pb) drained from historical or active mining areas in the IPB on the activity of a Pb inhibited enzyme (δ-aminolevulinic acid dehydratase, ALAD) in several bivalve species along the Gulf of Cadiz. Seven marine species (Chamelea gallina, Mactra corallina, Donax trunculus, Cerastoderma edule, Mytilus galloprovincialis, Scrobicularia plana and Crassostrea angulata) were collected at 12 sites from Mazagon, near the mouth of the rivers Tinto and Odiel (Spain), to Cacela Velha (Ria Formosa lagoon system, Portugal). Lead concentrations, ALAD activity and lead isotope ratios ( 206 Pb/ 204 Pb, 207 Pb/ 204 Pb and 208 Pb/ 204 Pb) were determined in the whole soft tissues. The highest Pb concentrations were determined in S. plana (3.50 ± 1.09 μg g -1 Pb d.w.) and D. trunculus (1.95 ± 0.10 μg g -1 Pb d.w.), while M. galloprovincialis and C. angulata showed the lowest Pb levels ( -1 Pb d.w.). In general, ALAD activity is negatively correlated with total Pb concentration. However this relationship is species dependent (e.g. linear for C. gallina ALAD = -0.36[Pb] + 0.79; r = 0.837; or exponential for M. galloprovincialis ALAD = 2.48e -8.3[Pb] ; r = 0.911). This indicates that ALAD activity has considerable potential as a biomarker of Pb and moreover, in marine bivalve species with different feeding habits. Lead isotope data

  15. Determination of lead in Smilax myosotiflora herbal preparations obtained in Malaysia.

    Science.gov (United States)

    Ang, H H; Lee, K L; Kiyoshi, M

    2004-08-01

    The DCA (Drug Control Authority), Malaysia implemented the phase 3 registration of traditional medicines on 1 January 1992 with special emphasis on the quality, efficacy and safety (including the presence of heavy metals) in all pharmaceutical dosage forms of traditional medicinal preparations. As such, a total of 100 traditional medicinal preparations, containing Smilax myosotiflora, in various pharmaceutical dosage forms, which were bought in the Malaysian market, were analysed for lead content using atomic absorption spectrophotometry. Results showed that 15% of the products analysed possessed 10.23-23.05 ppm of lead, and therefore, do not comply with the quality requirement for traditional medicines in Malaysia. The quality requirement for traditional medicines in Malaysia is that they should not exceed 10 ppm of lead. Out of these 15 products, five products exhibited 10.23-23.05 ppm of lead, in fact they have already been registered with the DCA Malaysia. However, the rest of the products, which possessed 12.24-20.72 ppm of lead, have still not been registered with the DCA Malaysia. Although this study successfully showed that only 85% of the products complied with the quality requirement for traditional medicines in Malaysia pertaining to lead, they cannot, however, be assumed to be safe from lead contamination because of batch-to-batch inconsistency.

  16. Determination of the pollution with lead in the batteries factory in Al-Saffera (Aleppo) and surrounding area

    International Nuclear Information System (INIS)

    Al-Oudat, M.; Al-Kharfan, K.; Al-Shamali, K.

    2007-10-01

    The study aimed to determine the lead concentrations in the ecosystem surrounding the batteries factory in Al-Saffera. The results showed that the lead levels were very high in both factory area and the surrounding agricultural area. Lead levels in air varied between 12 and 34 μg/m3 in the area outside the factory. The same trends were in both soil and plant samples, and normal washing does not decrease the lead level in plant samples to acceptable levels. Mean lead levels in blood was also high and ranged between 55 and 28 μg /dl for factory workers and village inhabitants respectively. In conclusion the authorities administration must take all necessary procedures to reduce the lead levels in the factory area and in the surrounding area.(Author)

  17. Determination of the pollution with lead in the batteries factory in Al-Saffera (Aleppo) and surrounding area

    Energy Technology Data Exchange (ETDEWEB)

    Al-Oudat, M; Al-Kharfan, K; Al-Shamali, K [Atomic Energy Commission, Damascus (Syrian Arab Republic), Dept. of Protection and Safety

    2007-10-15

    The study aimed to determine the lead concentrations in the ecosystem surrounding the batteries factory in Al-Saffera. The results showed that the lead levels were very high in both factory area and the surrounding agricultural area. Lead levels in air varied between 12 and 34 {mu}g/m3 in the area outside the factory. The same trends were in both soil and plant samples, and normal washing does not decrease the lead level in plant samples to acceptable levels. Mean lead levels in blood was also high and ranged between 55 and 28 {mu}g /dl for factory workers and village inhabitants respectively. In conclusion the authorities administration must take all necessary procedures to reduce the lead levels in the factory area and in the surrounding area.(Author)

  18. Experimental study using of a G-M counter and "1"3"7Cs source to measure the HVL with lead

    International Nuclear Information System (INIS)

    Kwon, Dae Cheol; Dong, Kyung Rae

    2016-01-01

    HVL(half-value layer) of lead was measured experimentally using a lead and "1"3"7Cs (370 kBq) source and a G-M counter in which is used a lot of material for shielding HVL measured. "1"3"7Cs in holder to 10 cm and start measuring the radiation. Continue addition of lead of the lead thickness of 1 mm one by one to continue the measurement. By measuring four times the natural radiation of 100 seconds and records the count value and the average rate to be displayed on the meter. Background radiation was a 4 times a count rate and the average 108 (100 s"-"1) as a result of measuring the average measurement, the standard deviation was determined to be 1.08 (s"-"1). An increase in the thickness of lead initial count rate starting from 920 (N) count rate is decreased with increase in the thickness of lead. Net counting rate, starting with the initial 8.12 (s"-"1) showed a decrease with increasing thickness, the standard deviation of the results was decreased from 0.303 (s"-"1) to 0.196 (s"-"1). Net counting rate is reduced to obtain the result that each half thickness of nappan about 7 mm. Was reduced similarly to the exponential function graph correlation coefficient (R"2) was found to be 0.9869. Half-value layer which is the initial net counting rate 7.514 (s"-"1) is a half the 7 mm to 3.757 (s"-"1). In conclusion, it was confirmed the theoretical HVL of lead 7.19 mm and experimentally measured results matched the measured HVL 7 mm

  19. Precise Determination of the 1s Lamb Shift in Hydrogen-Like Lead and Gold Using Microcalorimeters

    Science.gov (United States)

    Kraft-Bermuth, S.; Andrianov, V.; Bleile, A.; Echler, A.; Egelhof, P.; Grabitz, P.; Ilieva, S.; Kiselev, O.; Kilbourne, C.; McCammon, D.; hide

    2017-01-01

    Quantum electrodynamics in very strong Coulomb fields is one scope which has not yet been tested experimentally with sufficient accuracy to really determine whether the perturbative approach is valid. One sensitive test is the determination of the 1s Lamb shift in highly-charged very heavy ions. The 1s Lamb shift of hydrogen-like lead (Pb81+) and gold (Au78+) has been determined using the novel detector concept of silicon microcalorimeters for the detection of hard x-rays. The results of (260 +/- 53) eV for lead and (211 +/- 42) eV for gold are within the error bars in good agreement with theoretical predictions. To our knowledge, for hydrogen-like lead, this represents the most accurate determination of the 1s Lamb shift.

  20. Lead isotopes and trace metal ratios of aerosols as tracers of Pb pollution sources in Kanpur, India

    Science.gov (United States)

    Sen, Indra; Bizimis, Michael; Tripathi, Sachchida; Paul, Debajyoti; Tyagi, Swati; Sengupta, Deep

    2015-04-01

    The anthropogenic flux of Pb in the Earth's surface is almost an order of magnitude higher than its corresponding natural flux [1]. Identifying the sources and pathways of anthropogenic Pb in environment is important because Pb toxicity is known to have adverse effects on human health. Pb pollution sources for America, Europe, and China are well documented. However, sources of atmospheric Pb are unknown in India, particularly after leaded gasoline was phased out in 2000. India has a developing economy with a rapidly emerging automobile and high temperature industry, and anthropogenic Pb emission is expected to rise in the next decade. In this study, we report on the Pb- isotope compositions and trace metal ratios of airborne particulates collected in Kanpur, an industrial city in northern India. The Pb concentration in the airborne particulate matter varies between 14-216 ng/m3, while the other heavy metals vary by factor of 10 or less, e.g. Cd=0.3-3 ng/m3, As=0.4-3.5 ng/m3, Zn=36-161 ng/m3, and Cu=3-22 ng/m3. The 206Pb/207Pb, 208Pb/206Pb, and 208Pb/207Pb vary between 1.112 - 1.129, 2.123-2.141, and 2.409-2.424 respectively, and are highly correlated with each other (R2>0.9). Pb isotopes and trace metal data reveals that coal combustion is the major source of anthropogenic Pb in the atmosphere, with limited contribution from mining and smelting processes. We further conclude that combination of Pb isotope ratios and V/Pb ratios are powerful tracers for Pb source apportionment studies, which is otherwise difficult to differentiate based only on Pb systematics [1] Sen and Peucker-Ehrenbrink (2012), Environ. Sci. Technol.(46), 8601-8609

  1. Lead concentration distribution and source tracing of urban/suburban aquatic sediments in two typical famous tourist cities: Haikou and Sanya, China.

    Science.gov (United States)

    Dong, Zhicheng; Bao, Zhengyu; Wu, Guoai; Fu, Yangrong; Yang, Yi

    2010-11-01

    The content and spatial distribution of lead in the aquatic systems in two Chinese tropical cities in Hainan province (Haikou and Sanyan) show an unequal distribution of lead between the urban and the suburban areas. The lead content is significantly higher (72.3 mg/kg) in the urban area than the suburbs (15.0 mg/kg) in Haikou, but quite equal in Sanya (41.6 and 43.9 mg/kg). The frequency distribution histograms suggest that the lead in Haikou and in Sanya derives from different natural and/or anthropogenic sources. The isotopic compositions indicate that urban sediment lead in Haikou originates mainly from anthropogenic sources (automobile exhaust, atmospheric deposition, etc.) which contribute much more than the natural sources, while natural lead (basalt and sea sands) is still dominant in the suburban areas in Haikou. In Sanya, the primary source is natural (soils and sea sands).

  2. Voltammetric determination of cadmium and lead in human hair as healthy indicator

    International Nuclear Information System (INIS)

    Nasser, H.; Kherbik, R.

    2010-01-01

    Cadmium and Lead level were examined in hair of patients and healthy donors. Hair sample were collected and analyzed for their contents of the trace metals (Cd, Pb) by Voltammetry. It was found that the existence of Cadmium and Lead in the hair was significantly higher in the patients (19.7 μg/g - 38.2 μg/g) for lead, (0.4 μg/g - 2.1 μg/g) for cadmium. On the other hand, the healthy had lower concentration (7.8 μg/g - 8.8 μg/g) for Lead, (0.2 μg/g - 0.3 μg/g) for cadmium. In this study, hairs were analyzed to find the effect these elements on health. Correlation coefficients between the levels of the elements in hair found in this study showed that hair is a good indicator of Cadmium and Lead in the hair. The method is applicable as a tool for monitoring pollution level of groups.(author)

  3. Lead isotope ratios in lichen samples evaluated by ICP-ToF-MS to assess possible atmospheric pollution sources in Havana, Cuba.

    Science.gov (United States)

    Alvarez, Alfredo Montero; Estévez Alvarez, Juan R; do Nascimento, Clístenes Williams Araújo; González, Iván Pupo; Rizo, Oscar Díaz; Carzola, Lázaro Lima; Torres, Roberto Ayllón; Pascual, Jorge Gómez

    2017-01-01

    Epiphytic lichens, collected from 119 sampling sites grown over "Roistonea Royal Palm" trees, were used to assess the spatial distribution pattern of lead (Pb) and identify possible pollution sources in Havana (Cuba). Lead concentrations in lichens and topsoils were determined by flame atomic absorption spectrophotometry and inductively coupled plasma (ICP) atomic emission spectrometry, respectively, while Pb in crude oils and gasoline samples were measured by ICP-time of flight mass spectrometry (ICP-ToF-MS). Lead isotopic ratios measurements for lichens, soils, and crude oils were obtained by ICP-ToF-MS. We found that enrichment factors (EF) reflected a moderate contamination for 71% of the samples (EF > 10). The 206 Pb/ 207 Pb ratio values for lichens ranged from 1.17 to 1.20 and were a mixture of natural radiogenic and industrial activities (e.g., crude oils and fire plants). The low concentration of Pb found in gasoline (leaded gasoline is no longer used in Cuba.

  4. The potential of elemental and isotopic analysis of tree bark for discriminating sources of airborne lead contamination in the UK.

    Science.gov (United States)

    Bellis, D; McLeod, C W; Satake, K

    2001-02-01

    Samples of tree bark, which accumulate airborne material, were collected from seven locations in the UK to provide an indication of the magnitude and source of lead pollution. Measurement of the Pb content and 206/207Pb stable isotope ratio by inductively coupled plasma mass spectrometry revealed significant differences between the sites. The concentration of Pb varied over almost four orders of magnitude from 7.2 to 9,600 micrograms g-1, the maximum values being found near a 'secondary' Pb smelter. The 206/207Pb isotope ratios varied from 1.108 +/- 0.002 to 1.169 +/- 0.001. The lowest Pb concentrations and highest isotope ratios were detected in bark samples from the Scilly Isles, reflecting the low-level of industry and road traffic. In contrast, samples obtained from a city centre (Sheffield) and near a motorway (M1) contained 25-46 micrograms g-1 Pb and recorded the lowest 206/207Pb ratios. Higher concentrations in the vicinity of a coal-fired power station recorded a 206/207Pb ratio of 1.14, suggesting a significant contribution from fly-ash. The relative contribution of lead from petrol (206/207Pb = 1.08) and other sources such as coal (206/207Pb = 1.18) were thus estimated using mass balance equations. Tree bark near the lead smelter recorded an intermediate 206/207Pb ratio of 1.13 reflecting the processing of material of mixed origin.

  5. Determination of new time-temperature-transformation diagrams for lead-calcium alloys

    Energy Technology Data Exchange (ETDEWEB)

    Rossi, F.; Lambertin, M. [Arts et Metiers Paristech, LaBoMaP, ENSAM, Rue porte de Paris, 71250 Cluny (France); Delfaut-Durut, L. [CEA, centre de Valduc [SEMP, LECM], 21120 Is-sur-Tille (France); Maitre, A. [SPCTS, UFR Sciences et techniques, 87060 Limoges (France); Vilasi, M. [LCSM, Universite Nancy I, 54506 Vandoeuvre les Nancy (France)

    2008-12-01

    The Pb-Ca is an age hardening alloy that allows for an increase in the hardness compared to pure lead. The hardening is obtained after different successive ageing transformations. In addition, this hardening is followed by an overageing which induces a softening. The ageing and overageing transformation mechanisms are now well identified in lead-calcium alloys. In this paper, we propose to represent the domain of stability of each transformation via time-temperature-transformation diagrams for a calcium concentration from 600 to 1280 ppm and in a range of temperatures from -20 to 180 C. These diagrams are constructed with the data obtained by in situ ageing with metallographic observations, hardness and electrical resistance measurements. The specificities of lead-calcium such as its fast ageing at ambient temperature and its overageing over time required the design of specific devices to be able to identify the characteristics of these alloys. (author)

  6. Ion exchange separation of lead from strontium in certified reference samples and spectrophotometric determination of lead as extractable ion-pair of eosin2- and the lead-cryptand (2.2.2)2+ complex

    International Nuclear Information System (INIS)

    Al-Merey, R.; Al-Shayah, O.

    2004-01-01

    A two-step procedure including anion exchange separation of lead from strontium in geological reference samples and a spectrophotometric determination of the separated lead as lead-cryptate (2.2.2) complex is presented. The exchangeable anion Cl - of the ion exchange resin (Dowex 1x4) is changed to Br - in 6M HBr solution. Lead is quantitatively retained in the column from 0.5M HBr medium, while Sr 2+ , Ba 2+ , Ca 2+ , Mg 2+ , Na + , K + , Fe 3+ , Cr 3+ , and Al 3+ are passed through. Subsequently the retained Ph is eluted from the column with 6M HBr. The separation efficiency of the resin is controlled using mixed standard solution of (Pb, Sr, Ca, Mg, Ba, Na, K, Fe, Cr and Al), and radioactive tracer of 85 Sr and 131 Ba. The resin selectivity coefficient (K) of separating Pb from Sr is found to be K S r P b∼10 9 . The Spectrophotometric method of lead determination is based on the formation of lead-crytate (2.2.2) complex at pH 8.3 using borate/HCl as a buffer solution. Then the ion-pair of eosin 2+ and lead-cryptand (2.2.2) complex is extracted with chloroform, finally the absorbance of the extractable legend is measured at 550 nm. The extraction recovery, accuracy, precision, linearity and detection limit of the spectrophotometric method are 99.58%, 1.7%, 0.080μg mL -1 , o-9μg mL -1 , and 0.060μg mL -1 , respectively. (author)

  7. Tracing toxic elements sources using lead isotopes: An example from the San Antonio–El Triunfo mining district, Baja California Sur, México

    International Nuclear Information System (INIS)

    Gutiérrez-Caminero, Leopoldo; Weber, Bodo; Wurl, Jobst; Carrera-Muñoz, Mariela

    2015-01-01

    Highlights: • Provenance of toxic elements is investigated in a basin close to the mining district. • Stable lead isotope analyses assist to distinguish between sources of toxic elements. • Two major sources are identified: mine tailings and fault bounded mineralization. • There is evidence in the detritus of a different natural lead component. • An additional anthropogenic lead input is detectable from the soluble phases. - Abstract: Pollution of sediments and water bodies with toxic elements around the San Antonio–El Triunfo mining district, Baja California Sur, México is probably sourced from the tailings of abandoned mines that are hosted in mineralized Cretaceous granitoids. However, there is evidence to suggest local hot springs related to recent faults may be an additional source for contamination in the area. In this study, lead isotope signatures are applied to draw conclusions with regard to potential sources of toxic elements. Lead isotope ratios were analyzed from sulfides and scoria from the abandoned mines, fluvial sediments, and igneous rocks with secondary disseminated mineralization. To differentiate between superposed secondary and residual primary lead, leaching experiments were performed, and both leachate and residues were analyzed separately. Most of the residues from sediment samples have lead isotope ratios similar to those from the sulfides and scoria of the mining district, indicating that most of the lead in the detritus is related to the mineralized plutons. However, there is evidence of an additional detrital component. Lead isotope ratios from the leachates indicate a different source for the superimposed lead that is best explained by the contamination with the average Mexican industrial lead. Secondary disseminated mineralization that is related to younger, deep structures (hot springs) has different lead isotope ratios compared to massive vein sulfides and accounts for a significant amount in areas with high

  8. An assessment of contemporary atomic spectroscopic techniques for the determination of lead in blood and urine matrices

    Science.gov (United States)

    Parsons, Patrick J.; Geraghty, Ciaran; Verostek, Mary Frances

    2001-09-01

    The preparation and validation of a number of clinical reference materials for the determination of lead in blood and urine is described. Four candidate blood lead reference materials (Lots, 047-050), and four candidate urine lead reference materials (Lots, 034, 035, 037 and 038), containing physiologically-bound lead at clinically relevant concentrations, were circulated to up to 21 selected laboratories specializing in this analysis. Results from two interlaboratory studies were used to establish certified values and uncertainty estimates for these reference materials. These data also provided an assessment of current laboratory techniques for the measurement of lead in blood and urine. For the blood lead measurements, four laboratories used electrothermal atomization AAS, three used anodic stripping voltammetry and one used both ETAAS and ICP-MS. For the urine lead measurements, 11 laboratories used ETAAS (most with Zeeman background correction) and 10 used ICP-MS. Certified blood lead concentrations, ±S.D., ranged from 5.9±0.4 μg/dl (0.28±0.02 μmol/l) to 76.0±2.2 μg/dl (3.67±0.11 μmol/l) and urine lead concentrations ranged from 98±5 μg/l (0.47±0.02 μmol/l) to 641±36 μg/l (3.09±0.17 μmol/l). The highest concentration blood lead material was subjected to multiple analyses using ETAAS over an extended time period. The data indicate that more stringent internal quality control practices are necessary to improve long-term precision. While the certification of blood lead materials was accomplished in a manner consistent with established practices, the urine lead materials proved more troublesome, particularly at concentrations above 600 μg/l (2.90 μmol/l).

  9. An Environmentally Friendly, Cost-Effective Determination of Lead in Environmental Samples Using Anodic Stripping Voltammetry

    Science.gov (United States)

    Goldcamp, Michael J.; Underwood, Melinda N.; Cloud, Joshua L.; Harshman, Sean

    2008-01-01

    Contamination of the environment with heavy metals such as lead presents many health risks. Simple, effective, and field-portable methods for the measurement of toxic metals in environmental samples are vital tools for evaluating the risks that these contaminants pose. This article describes the use of new developments in anodic stripping…

  10. Determination of lead isotopes in Arctic and Antarctic snow and ice

    International Nuclear Information System (INIS)

    Rosman, K.J.R.; Chisholm, W.

    1994-01-01

    The development of high sensitivity mass spectrometry to measure Pb isotopes in Arctic and Antarctic snow and ice has provided a powerful tool for identifying sources of global Pb pollution. The combination of isotope abundance information with concentration measurements adds another dimension to analytical chemistry. (authors). 11 refs., 4 figs

  11. Determination of SoH of Lead-Acid Batteries by Electrochemical Impedance Spectroscopy

    Directory of Open Access Journals (Sweden)

    Monika Kwiecien

    2018-05-01

    Full Text Available The aging mechanisms of lead-acid batteries change the electrochemical characteristics. For example, sulfation influences the active surface area, and corrosion increases the resistance. Therefore, it is expected that the state of health (SoH can be reflected through differentiable changes in the impedance of a lead-acid battery. However, for lead-acid batteries, no reliable SoH algorithm is available based on single impedance values or the spectrum. Additionally, the characteristic changes of the spectrum during aging are unknown. In this work, lead-acid test cells were aged under specific cycle regimes known as AK3.4, and periodic electrochemical impedance spectroscopy (EIS measurements and capacity tests were conducted. It was examined that single impedance values increased linearly with capacity decay, but with varying slopes depending on the pre-history of the cell and measurement frequency of impedance. Thereby, possible reasons for ineffective SoH estimation were found. The spectra were fitted to an equivalent electrical circuit containing, besides other elements, an ohmic and a charge-transfer resistance of the negative electrode. The linear increase of the ohmic resistance and the charge-transfer resistance were characterized for the performed cyclic aging test. Results from chemical analysis confirmed the expected aging process and the correlation between capacity decay and impedance change. Furthermore, the positive influence of charging on the SoH could be detected via EIS. The results presented here show that SoH estimation using EIS can be a viable technique for lead-acid batteries.

  12. Mass-produced lonophore-based fluorescent microspheres for trace level determination of lead ions.

    Science.gov (United States)

    Telting-Diaz, Martin; Bakker, Eric

    2002-10-15

    The development and characterization of small, uniform, and mass-produced plasticized PVC-based sensing microspheres in view of rapid trace level analysis of lead ions is reported. Micrometer-sized particles obtained via an automated casting process were rendered selective for lead ions by doping them with highly selective components in a manner analogous to traditional optode sensing films. Single particles that contained the lipophilic ionophore N,N,N',N'-tetradodecyl-3-6-dioxaoctane-1-thio-8-oxodiamide (ETH 5493), the chromoionophore ETH 5418 together with a lipophilized indocarbocyanine derivative as internal reference dye (DiIC18), and lipophilic ion-exchanger sites sodium tetrakis[3,5-bistrifluoromethylphenyl]borate, yielded measurable lead responses at the low nanomolar level in pH buffered solutions. The detection limit for single particles was 3 x 10(-9) M at pH 5.7. The microspheres were fabricated via a reproducible formation of polymer droplets within a flowing aqueous phase followed by collection of spherical particles of approximately 13 microm in size. The particles were immobilized and assayed individually in a microflow cell via fluorescence microscopy. Selectivity patterns found were in agreement with those reported earlier for the lead-selective ligand ETH 5493, and all response functions were fully described by theory. In contrast to optode films that necessitated very long equilibration times and large sample volumes in diluted samples of analyte, particles exhibited extremely enhanced equilibrium response times. Thus, for lead sample concentrations at and above 5 x 10(-8) M, response times were approximately 3 min, whereas at the detection limit, complete equilibrium was recorded after just 15 min, with required sample volumes on the order of 1 mL This new class of microspheres appears to be suitable for rapid and sensitive ion detection at trace levels in environmental and biological applications.

  13. The effects of lead sources on oral bioaccessibility in soil and implications for contaminated land risk management

    International Nuclear Information System (INIS)

    Palmer, Sherry; McIlwaine, Rebekka; Ofterdinger, Ulrich; Cox, Siobhan F.; McKinley, Jennifer M.; Doherty, Rory; Wragg, Joanna; Cave, Mark

    2015-01-01

    Lead (Pb) is a non-threshold toxin capable of inducing toxic effects at any blood level but availability of soil screening criteria for assessing potential health risks is limited. The oral bioaccessibility of Pb in 163 soil samples was attributed to sources through solubility estimation and domain identification. Samples were extracted following the Unified BARGE Method. Urban, mineralisation, peat and granite domains accounted for elevated Pb concentrations compared to rural samples. High Pb solubility explained moderate-high gastric (G) bioaccessible fractions throughout the study area. Higher maximum G concentrations were measured in urban (97.6 mg kg −1 ) and mineralisation (199.8 mg kg −1 ) domains. Higher average G concentrations occurred in mineralisation (36.4 mg kg −1 ) and granite (36.0 mg kg −1 ) domains. Findings suggest diffuse anthropogenic and widespread geogenic contamination could be capable of presenting health risks, having implications for land management decisions in jurisdictions where guidance advises these forms of pollution should not be regarded as contaminated land. - Highlights: • Urban, mineralisation, peat and granite sources accounted for elevated Pb in soil. • Pb solubility was higher in urban and mineralisation domains. • Higher Pb solubility resulted in high oral bioaccessibility compared to rural areas. • Diffuse background and natural Pb contamination could pose human health risks. • Contaminated land policy should not dismiss diffuse or geogenic pollution sources. - Diffuse and widespread Pb sources displayed high oral bioaccessibility, providing implications for contaminated land risk assessment guidance that excludes these forms of pollution

  14. Quantitative determination of minor and trace elements in rocks and soils by spark source mass spectrometry

    International Nuclear Information System (INIS)

    Ure, A.M.; Bacon, J.R.

    1978-01-01

    Experimental details are given of the quantitative determination of minor and trace elements in rocks and soils by spark source mass spectrometry. The effects of interfering species, and corrections that can be applied, are discussed. (U.K.)

  15. Determination of the power of multielement aerosol composition emission from distant industrial sources

    International Nuclear Information System (INIS)

    Popova, S.A.; Kutsenogij, K.P.; Chankina, O.V.

    2008-01-01

    The results from the monitoring of the temporal variability of the multielement composition of atmospheric aerosols are presented. They are used to determine the emission power of a series of elements from distant sources.

  16. Determination of activation level energy of nuclear isomers by calibration of microspectra of radioactive sources

    International Nuclear Information System (INIS)

    Veres, A.; Pavlicsek, I.

    1980-01-01

    Nuclear isomers with unknown activation level were irradiated by calibrated radioactive sources. The integral cross sections were calculated for different energies of the sources. The activation energy was given by values coinciding with each other within the limits of error. The method made the determination of the unknown level of 1180+-10 keV of 195 Pt nucleus possible. (author)

  17. Selective masking and demasking for the stepwise complexometric determination of aluminium, lead and zinc from the same solution

    OpenAIRE

    Kayal, Nijhuma; Singh, Nahar

    2008-01-01

    Abstract Background A complexometric method based on selective masking and de-masking has been developed for the rapid determination of aluminium, lead and zinc from the same solution in glass and glass frit samples. The determination is carried out using potassium cyanide to mask zinc, and excess disodium salt of EDTA to mask lead and aluminium. The excess EDTA was titrated with standard Mn(II)SO4 solution using Erichrome Black-T as the indicator. Subsequently selective de-masking agents – t...

  18. Natural Radionuclides and Isotopic Signatures for Determining Carbonaceous Aerosol Sources, Aerosol Lifetimes, and Washout Processes

    International Nuclear Information System (INIS)

    Gaffney, Jeffrey

    2012-01-01

    This is the final technical report. The project description is as follows: to determine the role of aerosol radiative forcing on climate, the processes that control their atmospheric concentrations must be understood, and aerosol sources need to be determined for mitigation. Measurements of naturally occurring radionuclides and stable isotopic signatures allow the sources, removal and transport processes, as well as atmospheric lifetimes of fine carbonaceous aerosols, to be evaluated.

  19. Natural Radionuclides and Isotopic Signatures for Determining Carbonaceous Aerosol Sources, Aerosol Lifetimes, and Washout Processes

    Energy Technology Data Exchange (ETDEWEB)

    Gaffney, Jeffrey [Univ. of Arkansas, Little Rock, AR (United States)

    2012-12-12

    This is the final technical report. The project description is as follows: to determine the role of aerosol radiative forcing on climate, the processes that control their atmospheric concentrations must be understood, and aerosol sources need to be determined for mitigation. Measurements of naturally occurring radionuclides and stable isotopic signatures allow the sources, removal and transport processes, as well as atmospheric lifetimes of fine carbonaceous aerosols, to be evaluated.

  20. Circadian variation in QT dispersion determined from a 12-lead Holter recording

    DEFF Research Database (Denmark)

    Hansen, Stig; Rasmussen, Verner; Larsen, Klaus

    2007-01-01

    Background: QT dispersion is considered to reflect inhomogeneity of myocardial repolarization. Method: The circadian variation of QT interval dispersion was examined in 95 healthy subjects using 24-hour Holter monitoring. Three different methods of lead selection were applied: all 12 leads (QTdisp...... circadian variation using mean values of QTdisp 12, QTdisp 6, or QTdisp 2 obtained every hour, every 2, or every 4 hours, except in QTdisp 6, which demonstrated a significant circadian variation (P ... a significant circadian variation in QTdisp 12 and QTdisp 6 (P circadian variation was seen in QTdisp 2. A subdivision into 10-year age groups revealed that subjects at age >50 years had a significant circadian variation in QTdisp 12 and QTdisp 6, but not in QTdisp 2. Only in males...

  1. Ultratrace determination of lead in whole blood using electrothermal atomization laser-excited atomic fluorescence spectrometry.

    Science.gov (United States)

    Wagner, E P; Smith, B W; Winefordner, J D

    1996-09-15

    Laser-excited atomic fluorescence has been used to detect lead that was electrothermally atomized from whole blood in a graphite furnace. A 9 kHz repetition rate copper vapor laser pumped dye laser was used to excite the lead at 283.3 nm, and the resulting atomic fluorescence was detected at 405.8 nm. No matrix modification was used other than a 1:21 dilution of the whole blood with high-purity water. Using the atomic fluorescence peak area as the analytical measure and a background correction technique based upon a simultaneous measurement of the transmitted laser intensity, excellent agreement for NIST and CDC certified whole blood reference samples was obtained with aqueous standards. A limit of detection in blood of 10 fg/mL (100 ag absolute) was achieved.

  2. Radiochemical determination of lead-210 in uranium ores and air dusts

    International Nuclear Information System (INIS)

    Sill, C.W.; Willis, C.P.

    1977-01-01

    An improved procedure is described by which cellulose, glass fiber, and polystyrene filters can be wet-ashed and siliceous samples dissolved completely without loss of lead by either volatilization or spontaneous reduction to metal that occurs with dry ashing and/or treatment in platinum containers. The solution of bismuth-210 used to calibrate the β counter is prepared by chemical separation from a solution of lead-210 which is much more convenient and results in a product of higher specific activity than one prepared by neutron activation of stable bismuth. After separation from the samples by conventional chemical procedures, the bismuth-210 is precipitated on barium sulfate for β counting which is more convenient and gives a more uniform and reproducible deposit than is obtained by most other means

  3. ETAAS determination of thallium and silver from water matrix after colloidal precipitate flotation using lead(II) hexamethylenedithiocarbamate

    OpenAIRE

    TRAJCE STAFILOV; KATARINA CUNDEVA; GORICA PAVLOVSKA

    2001-01-01

    Afast method for the preconcentration of thallium and silver in nanogram quantities in fresh drinking waters (source, well, tap) and waters for irrigation using colloidal precipitate flotation is described. Lead(II) hexamethylenedithiocarbamate, Pb(HMDTC)2 played the role of flotation collector. The experimental conditions for the successful separation of thallium and silver (mass of Pb, amount ofHMDTC-, pHof the system, induction time, type of surfactant etc.) were optimized. After flotation...

  4. Determination of spallation residues in thin target: toward an hybrid reactor lead target simulation

    International Nuclear Information System (INIS)

    Audouin, L.; Tassan-Got, L.; Bernas, M.; Rejmund, F.; Stephan, C.; Taieb, J.; Boudard, A.; Fernandez, B.; Legrain, R.; Leray, S.; Volant, C.; Wlazlo, W.; Benlliure, J.; Casajeros, E.; Pereira, J.; Czajkowski, S.

    2001-01-01

    The production of spallation primary residual nuclei in thin target has been studied by measurement of isotopic yields distributions for several systems. Issues relevant for the design of accelerator-driven systems are presented. Monte-Carlo code abilities to reproduce data are studied in details; it is shown that calculations do not reproduce data in a satisfactory way. Future work orientations leading to an improvement of thin targets calculations and ultimately to a thick target simulation are discussed. (author)

  5. Determination of spallation residues in thin target: toward an hybrid reactor lead target simulation

    Energy Technology Data Exchange (ETDEWEB)

    Audouin, L.; Tassan-Got, L.; Bernas, M.; Rejmund, F.; Stephan, C.; Taieb, J. [Paris-11 Univ., 91- Orsay (France). Inst. de Physique Nucleaire; Enqvist, T.; Armbruster, P.; Ricciardi, M.V.; Schmidt, K.H. [GSI, Planckstrasse 1, Darmstadt (Germany); Boudard, A.; Fernandez, B.; Legrain, R.; Leray, S.; Volant, C.; Wlazlo, W. [CEA Saclay, Dept. d' Astrophysique, de Physique des Particules, de Physique Nucleaire et de l' Instrumentation Associee, 91 - Gif sur Yvette (France); Benlliure, J.; Casajeros, E.; Pereira, J. [University of Santiago de Compostella (Spain); Czajkowski, S. [Centre d' Etudes Nucleaires de Bordeaux Gradignan, CENBG, CNRS-IN2P3, 33 - Gradignan (France)

    2001-07-01

    The production of spallation primary residual nuclei in thin target has been studied by measurement of isotopic yields distributions for several systems. Issues relevant for the design of accelerator-driven systems are presented. Monte-Carlo code abilities to reproduce data are studied in details; it is shown that calculations do not reproduce data in a satisfactory way. Future work orientations leading to an improvement of thin targets calculations and ultimately to a thick target simulation are discussed. (author)

  6. Total Arsenic, Cadmium, and Lead Determination in Brazilian Rice Samples Using ICP-MS

    OpenAIRE

    Mataveli, Lidiane Raquel Verola; Buzzo, Márcia Liane; Arauz, Luciana Juncioni de; Carvalho, Maria de Fátima Henriques; Arakaki, Edna Emy Kumagai; Matsuzaki, Richard; Tiglea, Paulo

    2016-01-01

    This study is aimed at investigating a suitable method for rice sample preparation as well as validating and applying the method for monitoring the concentration of total arsenic, cadmium, and lead in rice by using Inductively Coupled Plasma Mass Spectrometry (ICP-MS). Various rice sample preparation procedures were evaluated. The analytical method was validated by measuring several parameters including limit of detection (LOD), limit of quantification (LOQ), linearity, relative bias, and rep...

  7. Determination of lead in treated crayfish Procambarus clarkii: accumulation in different tissues

    Energy Technology Data Exchange (ETDEWEB)

    Pastor, A.; Medina, J.; Del Ramo, J.; Torreblanca, A.; Diaz-Mayans, J.; Hernandez, F.

    1988-09-01

    The continual loading of trace metals into our environment represents a water pollution problem due to their toxic effects on aquatic biota. In addition, metal ions can be incorporated into food chains and concentrated by aquatic organisms to a level that affects their physiological state. There are several investigations on the toxic effects and bioaccumulation of lead in fishes, molluscs, and crustaceans. Lake Albufera (Valencia, Spain) and the surrounding rice-field waters are subjected to large loads of sewage and toxic industrial residues (including heavy metals) from many urban wastewaters in the area. In 1978, the American red crayfish Procambarus clarkii (Girard) appeared in Lake Albufera. The crayfish have reached a high density producing ecological and agricultural economic problems in rice crops. The crayfish is being fished commercially for human consumption without adequate protection to human health. The purpose of the present study was to investigate the accumulation of lead in tissues of the crayfish P. clarkii following short term lead exposure at several sublethal concentrations. The gills, midgut glands, antennal glands and muscle were analyzed by atomic absorption spectrophotometry.

  8. Total Arsenic, Cadmium, and Lead Determination in Brazilian Rice Samples Using ICP-MS.

    Science.gov (United States)

    Mataveli, Lidiane Raquel Verola; Buzzo, Márcia Liane; de Arauz, Luciana Juncioni; Carvalho, Maria de Fátima Henriques; Arakaki, Edna Emy Kumagai; Matsuzaki, Richard; Tiglea, Paulo

    2016-01-01

    This study is aimed at investigating a suitable method for rice sample preparation as well as validating and applying the method for monitoring the concentration of total arsenic, cadmium, and lead in rice by using Inductively Coupled Plasma Mass Spectrometry (ICP-MS). Various rice sample preparation procedures were evaluated. The analytical method was validated by measuring several parameters including limit of detection (LOD), limit of quantification (LOQ), linearity, relative bias, and repeatability. Regarding the sample preparation, recoveries of spiked samples were within the acceptable range from 89.3 to 98.2% for muffle furnace, 94.2 to 103.3% for heating block, 81.0 to 115.0% for hot plate, and 92.8 to 108.2% for microwave. Validation parameters showed that the method fits for its purpose, being the total arsenic, cadmium, and lead within the Brazilian Legislation limits. The method was applied for analyzing 37 rice samples (including polished, brown, and parboiled), consumed by the Brazilian population. The total arsenic, cadmium, and lead contents were lower than the established legislative values, except for total arsenic in one brown rice sample. This study indicated the need to establish monitoring programs for emphasizing the study on this type of cereal, aiming at promoting the Public Health.

  9. Total Arsenic, Cadmium, and Lead Determination in Brazilian Rice Samples Using ICP-MS

    Directory of Open Access Journals (Sweden)

    Lidiane Raquel Verola Mataveli

    2016-01-01

    Full Text Available This study is aimed at investigating a suitable method for rice sample preparation as well as validating and applying the method for monitoring the concentration of total arsenic, cadmium, and lead in rice by using Inductively Coupled Plasma Mass Spectrometry (ICP-MS. Various rice sample preparation procedures were evaluated. The analytical method was validated by measuring several parameters including limit of detection (LOD, limit of quantification (LOQ, linearity, relative bias, and repeatability. Regarding the sample preparation, recoveries of spiked samples were within the acceptable range from 89.3 to 98.2% for muffle furnace, 94.2 to 103.3% for heating block, 81.0 to 115.0% for hot plate, and 92.8 to 108.2% for microwave. Validation parameters showed that the method fits for its purpose, being the total arsenic, cadmium, and lead within the Brazilian Legislation limits. The method was applied for analyzing 37 rice samples (including polished, brown, and parboiled, consumed by the Brazilian population. The total arsenic, cadmium, and lead contents were lower than the established legislative values, except for total arsenic in one brown rice sample. This study indicated the need to establish monitoring programs for emphasizing the study on this type of cereal, aiming at promoting the Public Health.

  10. Lead isotope ratios in six lake sediment cores from Japan Archipelago: Historical record of trans-boundary pollution sources.

    Science.gov (United States)

    Hosono, Takahiro; Alvarez, Kelly; Kuwae, Michinobu

    2016-07-15

    Sediment cores from six lakes situated from north to south on the Japanese Archipelago were collected during 2009-2010 to investigate the hypothesis that deposition of lead (Pb) was coming from East Asia (including China, South Korea and eastern part of Russia). Accumulation rates and ages of the lake sediment were estimated by the (210)Pb constant rate of supply model and (137)Cs inputs to reconstruct the historical trends of Pb accumulation. Cores from four lakes located in the north and central Japan, showed clear evidence of Pb pollution with a change in the (206)Pb/(207)Pb and (208)Pb/(207)Pb ratios in the recent sediment as compared to the deeper sediment. Among the six studied lakes, significant inputs of anthropogenic lead emissions were observed at Lake Mikazuki (north Hokkaido in north Japan), Lake Chokai (north of Honshu), and Lake Mikuriga (central part of Honshu). Pb isotopic comparison of collected core sediment and previously reported data for wet precipitation and aerosols from different Asian regions indicate that, before 1900, Pb accumulated in these three lakes was not affected by trans-boundary sources. Lake Mikazuki started to receive Pb emissions from Russia in early 1900s, and during the last two decades, this lake has been affected by trans-boundary Pb pollution from northern China. Lake Chokai has received Pb pollutant from northern China since early 1900s until 2009, whereas for the Lake Mikuriga the major Pb contaminant was transported from southern China during the past 100years. The results of our study demonstrate that Japan Archipelago has received trans-boundary Pb emissions from different parts of East Asian region depending on location, and the major source region has changed historically. Copyright © 2016 Elsevier B.V. All rights reserved.

  11. A next-to-leading determination of the singlet axial charge and the polarized gluon content of the nucleon

    CERN Document Server

    Ball, R D; Ridolfi, G

    1996-01-01

    We perform a full next-to-leading analysis of the the available experimental data on the polarized structure function g_1 of the nucleon, and give a precise determination of its singlet axial charge together with a thorough assessment of the theoretical uncertainties. We find that the data are now sufficient to separately determine first moments of the polarized quark and gluon distributions and show in particular that the gluon contribution is large and positive.

  12. Non-destructive γ-spectrometric determination of mercury and gold in sea water after preconcentration by lead sulphide

    International Nuclear Information System (INIS)

    Alexandrov, S.

    1976-01-01

    A method is described for determination of mercury and gold in sea-water, based on preconcentration of these elements by retention on a column of lead sulphide at pH1 (nitric and sulphuric acids), and γ-spectrometry. Mercury (0.8 +-0.2 μg/l) and gold (6 +- 3 ng/l) have been determined in a sample from the Black Sea, taken near Varna. (author)

  13. Optical Determination of Lead Chrome Green in Green Tea by Fourier Transform Infrared (FT-IR Transmission Spectroscopy.

    Directory of Open Access Journals (Sweden)

    Xiaoli Li

    Full Text Available The potential of Fourier transform infrared (FT-IR transmission spectroscopy for determination of lead chrome green in green tea was investigated based on chemometric methods. Firstly, the qualitative analysis of lead chrome green in tea was performed based on partial least squares discriminant analysis (PLS-DA, and the correct rate of classification was 100%. And then, a hybrid method of interval partial least squares (iPLS regression and successive projections algorithm (SPA was proposed to select characteristic wavenumbers for the quantitative analysis of lead chrome green in green tea, and 19 wavenumbers were obtained finally. Among these wavenumbers, 1384 (C = C, 1456, 1438, 1419(C = N, and 1506 (CNH cm-1 were the characteristic wavenumbers of lead chrome green. Then, these 19 wavenumbers were used to build determination models. The best model was achieved by least squares support vector machine (LS-SVMalgorithm with high coefficient of determination and low root-mean square error of prediction set (R2p = 0.864 and RMSEP = 0.291. All these results indicated the feasibility of IR spectra for detecting lead chrome green in green tea.

  14. Atmospheric and children's blood lead as indicators of vehicular traffic and other emission sources in Mumbai, India

    Energy Technology Data Exchange (ETDEWEB)

    Tripathi, R.M.; Raghunath, R.; Vinod Kumar, A.; Sastry, V.N.; Sadasivan, S. [Environmental Assessment Division, Bhabha Atomic Research Centre, 400 085 Mumbai (India)

    2001-02-21

    Average concentration of Pb in atmospheric air particulates in different suburbs of Mumbai was studied for almost a decade and its spatial and temporal profiles are discussed in relation to emission sources. In general the concentration of Pb in all the residential suburban atmosphere is well below the Central Pollution Control Board (CPCB, 1994) prescribed limit of 1.5 {mu}g m{sup -3} barring a few exceptions for some residential/industrial sites, such as those of Thane and Kurla scrap yards. The correlation between blood lead of children and air lead reveals that the blood Pb level in children could increase by 3.6 {mu}g dl{sup -1} for an incremental rise of 1.0 {mu}g Pb m{sup -3} of air. The temporal profile of air Pb values indicates a decreasing trend in residential suburbs (Khar: 1984, 0.39 {mu}g m{sup -3}; 1996, 0.17 {mu}g m{sup -3}) as well as in suburban residential areas with low traffic (Goregaon: 1984, 0.53 {mu}g m{sup -3}; 1996, 0.30 {mu}g m{sup -3})

  15. Determinants, obstacles, sources and cooperation to innovation in Portuguese firms, using community innovation survey

    Science.gov (United States)

    Correia, Aldina; Braga, Alexandra; Braga, Vitor

    2017-06-01

    Innovation is a topic of interest for the management researchers, confirmed by the creation of a Community Innovation Survey, which is an harmonised tool designed to provide information about Innovation in European Union enterprises. In this study, we use factorial analysis to identify the determinants and obstacles to innovation in Portuguese firms. The sources of innovation and cooperation to innovation are also analysed, using crossed information. For the determinants of innovation six factors were identified: Production costs and impacts to health and environment, Process and product innovation, Organizational innovation, Institutional sources of information, Others sources of information and Market sources of information. Obstacles to innovation were clustered into three groups: Knowledge and market factors, Cost factors and Reasons not to innovate. The main sources of innovation identified, in this study, are Suppliers and Clients, located in Portugal and in Europe. Cooperation partners are also majority Clients and Suppliers, in addition to other enterprises in the same group.

  16. Determination of trace amount of lead in industrial and municipal effluent water samples based on dispersive liquid-liquid extraction

    Energy Technology Data Exchange (ETDEWEB)

    Shirkhanloo, H. [Iranian Petroleum Industry Health Research Institute, Occupational and Environmental Health Research Center, Tehran (Iran, Islamic Republic of); Sedighi, K.; Mousavi, H. Z., E-mail: hzmousavi@semnan.ac.ir [Semnan University, College of Science, Department of Chemistry, Semnan (Iran, Islamic Republic of)

    2014-10-01

    In this study, a simple, sensitive and accurate method was developed for the determination of lead ion by combining ionic liquid dispersive liquid-liquid extraction (Il-DLL E) with flame atomic absorption spectrometry. Tetraethyl thiuram disulfide (Tetd), acetone and 1-octyl-3m ethylimidazolium hexafluorophosphate [(C{sub 8}MIM) (PF{sub 6})] were used as the chelating agent, dispersive and extraction solvent, respectively. Under the optimal conditions, the calibration graph was linear in the range of 5-190 μg L{sup -1} of lead and the detection limit was 0.8 μg L{sup -1} with a sample volume of 200 ml. The proposed method was validated by the analysis of one certified reference material and applied successfully to the determination of lead in real water samples. (Author)

  17. Determination of trace amount of lead in industrial and municipal effluent water samples based on dispersive liquid-liquid extraction

    International Nuclear Information System (INIS)

    Shirkhanloo, H.; Sedighi, K.; Mousavi, H. Z.

    2014-01-01

    In this study, a simple, sensitive and accurate method was developed for the determination of lead ion by combining ionic liquid dispersive liquid-liquid extraction (Il-DLL E) with flame atomic absorption spectrometry. Tetraethyl thiuram disulfide (Tetd), acetone and 1-octyl-3m ethylimidazolium hexafluorophosphate [(C 8 MIM) (PF 6 )] were used as the chelating agent, dispersive and extraction solvent, respectively. Under the optimal conditions, the calibration graph was linear in the range of 5-190 μg L -1 of lead and the detection limit was 0.8 μg L -1 with a sample volume of 200 ml. The proposed method was validated by the analysis of one certified reference material and applied successfully to the determination of lead in real water samples. (Author)

  18. Determination of contents of carbonate and hydrogen carbonate in solutions for alkaline leading of uranium ores

    International Nuclear Information System (INIS)

    Radil, V.

    1988-01-01

    The new analytical method is based on the determination of the molar ratio carbonate - hydrogen carbonate using the measured concentration of hydrogen ions, the determination of the dissociation constant of carbonic acid for different values of ionic strength. The concentration of hydrogen ions was measured with a Metrohm 632 pH meter with the use of a combined glass electrode. The content of total carbonate carbon was determined coulometrically and the uranium content was determined by extraction with tributyl phosphate and by spectrometry of the complex of uranyl ions with Arsenazo III. Model solutions were used for the experiments which contained a high concentration of sulfate ions, thiosulfate ions, uranium and various proportions of carbonate and hydrogen carbonate. The composition of the individual samples of the extraction solutions are tabulated. The calibration was made of the glass combined electrode at different ionic strength, the values determined of dissociation constants of carbonic acid for different ionic strength. The mathematical procedure is described for the calculation of molar concentrations of carbonate and hudrogen carbonate and the results are presented of the analysis of model solutions. (E.S.). 5 tabs., 1 fig., 5 refs

  19. Determination of Lung-to-Blood Absorption Rates for Lead and Bismuth which are Appropriate for Radon Progeny

    International Nuclear Information System (INIS)

    Marsh, J.W.; Birchall, A.

    1999-01-01

    The ICRP Publication 66 Human Respiratory Tract Model (HRTM) treats clearance as a competitive process between absorption into blood and particle transport to the gastrointestinal tract and lymphatics. The ICRP recommends default absorption rates for lead and bismuth in ICRP Publication 71 but states that the values are not appropriate for short-lived radon progeny. This paper describes an evaluation of published data from volunteer experiments to estimate the absorption half-times of lead and bismuth that are appropriate for short-lived radon progeny. The absorption half-time for lead was determined to be 10±2 h, based on 212 Pb lung and blood retention data from several studies. The absorption half-time for bismuth was estimated to be about 13 h, based on 212 Bi urinary excretion data from one experiment and the ICRP biokinetic model for bismuth as a decay product of lead. (author)

  20. Selective masking and demasking for the stepwise complexometric determination of aluminium, lead and zinc from the same solution

    Directory of Open Access Journals (Sweden)

    Singh Nahar

    2008-03-01

    Full Text Available Abstract Background A complexometric method based on selective masking and de-masking has been developed for the rapid determination of aluminium, lead and zinc from the same solution in glass and glass frit samples. The determination is carried out using potassium cyanide to mask zinc, and excess disodium salt of EDTA to mask lead and aluminium. The excess EDTA was titrated with standard Mn(IISO4 solution using Erichrome Black-T as the indicator. Subsequently selective de-masking agents – triethanolamine, 2,3-dimercaptopropanol and a formaldehyde/acetone mixture – were used to determine quantities of aluminium, lead and zinc in a stepwise and selective manner. Results The accuracy of the method was established by analysing glass certified reference material NBS 1412. The standard deviation of the measurements, calculated by analysing five replicates of each sample, was found to be less than 1.5% for the method proposed. Conclusion The novelty of the method lies in its simplicity and accuracy afforded by there not being a need for a prior separation or instrumentation. The proposed method was found to be highly selective for the precise determination of aluminum, zinc and lead in the routine analysis of glass batch and allied materials.

  1. Chemical sensors in natural water: peculiarities of behaviour of chalcogenide glass electrodes for determination of copper, lead and cadmium ions

    International Nuclear Information System (INIS)

    Seleznev, B.L.; Legin, A.V.; Vlasov, Yu.G.

    1996-01-01

    Specific features of chemical sensors (chalcogenide glass and crystal ion-selective electrodes) behaviour have been studied to determine copper (2), lead, cadmium and fluorine in the course of in situ measurements, including long-term uninterrupted testing, for solving the problem of inspection over natural water contamination. 16 refs., 3 figs., 2 tabs

  2. Conflict over condition-dependent sex allocation can lead to mixed sex-determination systems

    NARCIS (Netherlands)

    Kuijper, Bram; Pen, Ido

    Theory suggests that genetic conflicts drive turnovers between sex-determining mechanisms, yet these studies only apply to cases where sex allocation is independent of environment or condition. Here, we model parent-offspring conflict in the presence of condition-dependent sex allocation, where the

  3. Conflict over condition-dependent sex allocation can lead to mixed sex-determination systems

    NARCIS (Netherlands)

    Kuijper, Bram; Pen, Ido

    2014-01-01

    Theory suggests that genetic conflicts drive turnovers between sex-determining mechanisms, yet these studies only apply to cases where sex allocation is independent of environment or condition. Here, we model parent-offspring conflict in the presence of condition-dependent sex allocation, where the

  4. Application of laser ablation inductively coupled plasma multicollector mass spectometry in determination of lead isotope ratios in common glass for forensic purposes

    International Nuclear Information System (INIS)

    Sjåstad, Knut-Endre; Andersen, Tom; Simonsen, Siri Lene

    2013-01-01

    Samples of glass used as trace evidence in criminal cases are commonly small, with particle sizes below a millimeter. To perform chemical analysis suitable for forensic purposes, methods capable of analyzing such small samples are required. In this paper, analyses of lead isotope ratios by means of laser ablation inductively coupled multicollector mass spectrometry (LA-MC-ICP-MS) are presented. Sampling by use of laser ablation allows fragments down to 0.1 mg to be analyzed with sufficient precision to discriminate between glasses of different origin. In fact, the use of lead isotopes determined by LA-MC-ICP-MS approaches the discrimination attainable by multicollector inductively coupled plasma mass spectrometry (MC-ICP-MS) analysis of dissolved samples of 5 mg or more. Further, we have obtained a probability distribution by two dimensional kernel density estimates for the collected data set as an alternative presentation method to the well-established bivariate plot. The underlying information available from kernel density estimates is of importance for forensic scientists involved in probabilistic interpretation of physical evidence. - Highlights: • Lead isotope ratios prove suitable to discriminate glass for forensic purposes. • 96% of glass samples from different sources were separated by lead isotopic ratios. • Laser ablation allows fragments of glass with extension of 0.5 mm to be analyzed. • Isotopic ratios of lead are well suited for statistical analysis of evidence

  5. Pressurizer /Auxiliary Spray Piping Stress Analysis For Determination Of Lead Shielding Maximum Allow Able Load

    International Nuclear Information System (INIS)

    Setjo, Renaningsih

    2000-01-01

    Piping stress analysis for PZR/Auxiliary Spray Lines Nuclear Power Plant AV Unit I(PWR Type) has been carried out. The purpose of this analysis is to establish a maximum allowable load that is permitted at the time of need by placing lead shielding on the piping system on class 1 pipe, Pressurizer/Auxiliary Spray Lines (PZR/Aux.) Reactor Coolant Loop 1 and 4 for NPP AV Unit one in the mode 5 and 6 during outage. This analysis is intended to reduce the maximum amount of radiation dose for the operator during ISI ( In service Inspection) period.The result shown that the maximum allowable loads for 4 inches lines for PZR/Auxiliary Spray Lines is 123 lbs/feet

  6. Determination of silver, bismuth, cadmium, copper, lead, and zinc in geologic materials by atomic absorption spectrometry with tricaprylylmethylammonium chloride

    Science.gov (United States)

    Viets, J.G.

    1978-01-01

    Interferences commonly encountered in the determination of silver, bismuth, cadmium, copper, lead, and zinc at crustal abundance levels are effectively eliminated using a rapid, sensitive, organic extraction technique. A potassium chlorate-hydrochloric acid digestion solubilizes the metals not tightly bound in the silicate lattice of rocks, soils, and stream sediments. The six metals are selectively extracted into a 10% Aliquat 336-MIBK organic phase in the presence of ascorbic acid and potassium iodide. Metals in the organic extract are determined by flame atomic absorption spectrometry to the 0.02-ppm level for silver, cadmium, copper, and zinc and to the 0.2-ppm level for bismuth and lead with a maximum relative standard deviation of 18.8% for known reference samples. An additional hydrofluoric acid digestion may be used to determine metals substituted in the silicate lattice.

  7. The effect of different propolis harvest methods on its lead contents determined by ET AAS and UV-visS

    Energy Technology Data Exchange (ETDEWEB)

    Sales, A. [Department of Analytical Chemistry, Faculty of Biochemistry, Chemistry and Pharmacy, National University of Tucuman, Ayacucho 471, 4000 Tucuman (Argentina)]. E-mail: amsales@fbqf.unt.edu.ar; Alvarez, A. [National Institute of Agricultural Technology (INTA), Experimental Station Famailla, Ruta 301, Km 32, Famailla, Tucuman (Argentina); Areal, M. Rodriguez [Department of Analytical Chemistry, Faculty of Biochemistry, Chemistry and Pharmacy, National University of Tucuman, Ayacucho 471, 4000 Tucuman (Argentina); Maldonado, L. [National Institute of Agricultural Technology (INTA), Experimental Station Famailla, Ruta 301, Km 32, Famailla, Tucuman (Argentina); Marchisio, P. [Department of Analytical Chemistry, Faculty of Biochemistry, Chemistry and Pharmacy, National University of Tucuman, Ayacucho 471, 4000 Tucuman (Argentina); Rodriguez, M. [Department of Analytical Chemistry, Faculty of Biochemistry, Chemistry and Pharmacy, National University of Tucuman, Ayacucho 471, 4000 Tucuman (Argentina); Bedascarrasbure, E. [National Institute of Agricultural Technology (INTA), Experimental Station Famailla, Ruta 301, Km 32, Famailla, Tucuman (Argentina)

    2006-10-11

    Argentinean propolis is exported to different countries, specially Japan. The market demands propolis quality control according to international standards. The analytical determination of some metals, as lead in food, is very important for their high toxicity even in low concentrations and because of their harmful effects on health. Flavonoids, the main bioactive compounds of propolis, tend to chelate metals as lead, which becomes one of the main polluting agents of propolis. The lead found in propolis may come from the atmosphere or it may be incorporated in the harvest, extraction and processing methods. The aim of this work is to evaluate lead level on Argentinean propolis determined by electrothermal atomic absorption spectrometry (ET AAS) and UV-vis spectrophotometry (UV-visS) methods, as well as the effect of harvest methods on those contents. A randomized test with three different treatments of collection was made to evaluate the effect of harvest methods. These procedures were: separating wedges (traditional), netting plastic meshes and stamping out plastic meshes. By means of the analysis of variance technique for multiple comparisons (ANOVA) it was possible to conclude that there are significant differences between scraped and mesh methods (stamped out and mosquito netting meshes). The results obtained in the present test would allow us to conclude that mesh methods are more advisable than scraped ones in order to obtain innocuous and safe propolis with minor lead contents. A statistical comparison of lead determination by both, ET AAS and UV-visS methods, demonstrated that there is not a significant difference in the results achieved with the two analytical techniques employed.

  8. Determination of Trace Amounts of Lead with ETAAS After Single Drop Microextraction and Dispersive Liquid Liquid Microextraction Methods

    Directory of Open Access Journals (Sweden)

    Efeçınar M.

    2013-04-01

    Full Text Available Two liquid-phase microextraction procedures, single-drop microextraction (SDME and dispersive liquid–liquid microextraction (DLLME, have been developed for the determination of lead by electrothermal atomic absorption spectrometry (ETAAS. Both methods were based on the formation of lead iodide-Rhodamine B complex which is in phosphoric acid medium. In the presence of KI, anionic lead iodide was complexed with Rhodamine B as an ion-association complex. Several factors that may be affected on the SDME and DLLME methods were optimized. In the optimum experimental conditions, the limit of detection (3s and the enhancement factor were 0.008 μgL−1 and 152 for SDME and 0.0129 μgL−1 and 89 for DLLME respectively. The relative standard deviation (RSD for eight replicate determinations of 0.25 μgL−1 Pb was 4.6% for SDME and 0.5 μgL−1 Pb was 2.9% for DLLME. The developed methods were validated by the analysis of certified reference materials, and applied successfully to the determination of lead in several water and food samples.

  9. Development and validation of a novel, simple, and accurate spectrophotometric method for the determination of lead in human serum.

    Science.gov (United States)

    Shayesteh, Tavakol Heidari; Khajavi, Farzad; Khosroshahi, Abolfazl Ghafuri; Mahjub, Reza

    2016-01-01

    The determination of blood lead levels is the most useful indicator of the determination of the amount of lead that is absorbed by the human body. Various methods, like atomic absorption spectroscopy (AAS), have already been used for the detection of lead in biological fluid, but most of these methods are based on complicated, expensive, and highly instructed instruments. In this study, a simple and accurate spectroscopic method for the determination of lead has been developed and applied for the investigation of lead concentration in biological samples. In this study, a silica gel column was used to extract lead and eliminate interfering agents in human serum samples. The column was washed with deionized water. The pH was adjusted to the value of 8.2 using phosphate buffer, and then tartrate and cyanide solutions were added as masking agents. The lead content was extracted into the organic phase containing dithizone as a complexion reagent and the dithizone-Pb(II) complex was formed and approved by visible spectrophotometry at 538 nm. The recovery was found to be 84.6 %. In order to validate the method, a calibration curve involving the use of various concentration levels was calculated and proven to be linear in the range of 0.01-1.5 μg/ml, with an R (2) regression coefficient of 0.9968 by statistical analysis of linear model validation. The largest error % values were found to be -5.80 and +11.6 % for intra-day and inter-day measurements, respectively. The largest RSD % values were calculated to be 6.54 and 12.32 % for intra-day and inter-day measurements, respectively. Further, the limit of detection (LOD) was calculated to be 0.002 μg/ml. The developed method was applied to determine the lead content in the human serum of voluntary miners, and it has been proven that there is no statistically significant difference between the data provided from this novel method and the data obtained from previously studied AAS.

  10. Determination of serum cadmium and lead in patients of ischemic hear disease associated with or without hypertension and diabetes mellitus

    International Nuclear Information System (INIS)

    Nagra, S.A.; Zikrya, B.; Maqbool, T.

    1999-01-01

    Human health and trace minerals are closely associated with each other. The vital role of trace elements has become clear in the recent years. The relation of trace elements in serum varies with the state of human health, ecology and under different pathological conditions. Determination of cadmium, and lead in the blood serum of normal, hypertensive patients, Ischemic heart patients, diabetic patients, hypertensive patients having diabetes, ischemic heart patients with diabetes, and hypertensive patients having ischemic heart disease, was carried out by using atomic absorption spectroscopic techniques. The results indicated that the concentration of cadmium and lead was elevated as compared with the normal and discussed in this paper. (author)

  11. Application of extraction-chromatographic concentration to atomic absorption determination of lead and cadmium in drinking and sea water

    International Nuclear Information System (INIS)

    Bol'shova, T.A.; Agapkina, G.I.; Ershova, N.I.; Narankho, K.E.

    1988-01-01

    To increase the detection limits for lead and cadmium atomic-absorption determination in natural waters methods of extraction-chromatographic concentration of these metals using tri-n-octylamine (TOA) on polytetrafluoroethylene (PTFE) is developed. Chromatograpy was carried out from 1.5-2.0 M HBr solutions. For cadmium and lead elution acetic acid was used. It is shown that extraction-chromatographic concentration permits to decrease limits of metal atomic-absorption detection by 10 3 with the 500 ml volume sample analysis

  12. Precise determination of the neutron scattering length of lead isotopes 204Pb,207Pb and 208Pb by neutron interferometry

    International Nuclear Information System (INIS)

    Ioffe, A.; Ermakov, O.; Karpikhin, I.; Krupchitsky, P.; Mikula, P.; Lukas, P.; Vrana, M.

    2000-01-01

    The neutron scattering length of lead isotopes 204 Pb, 207 Pb and 208 Pb are determined by a set of neutron interferometry experiments. The obtained values b (208) =9.494(30) fm, b (207) =9.286(16) fm, b (204) =10.893(78) fm have much higher accuracy then current table data. Together with the precise value of b for natural lead, these results represent a complete set of data and allow one to calculate b (206) =9.221(69) fm, which is in the very good agreement with the present day experimental value. (orig.)

  13. Determination of lead in bone tissues by axially viewed inductively coupled plasma multichannel-based emission spectrometry.

    Science.gov (United States)

    Grotti, Marco; Abelmoschi, Maria Luisa; Dalla Riva, Simona; Soggia, Francesco; Frache, Roberto

    2005-04-01

    A new procedure for determining low levels of lead in bone tissues has been developed. After wet acid digestion in a pressurized microwave-heated system, the solution was analyzed by inductively coupled plasma multichannel-based emission spectrometry. Internal standardization using the Co 228.615 nm reference line was chosen as the optimal method to compensate for the matrix effects from the presence of calcium and nitric acid at high concentration levels. The detection limit of the procedure was 0.11 microg Pb g(-1) dry mass. Instrumental precision at the analytical concentration of approximately 10 microg l(-1) ranged from 6.1 to 9.4%. Precision of the sample preparation step was 5.4%. The concentration of lead in SRM 1486 (1.32+/-0.04 microg g(-1)) found using the new procedure was in excellent agreement with the certified level (1.335+/-0.014 microg g(-1)). Finally, the method was applied to determine the lead in various fish bone tissues, and the analytical results were found to be in good agreement with those obtained through differential pulse anodic stripping voltammetry. The method is therefore suitable for the reliable determination of lead at concentration levels of below 1 microg g(-1) in bone samples. Moreover, the multi-element capability of the technique allows us to simultaneously determine other major or trace elements in order to investigate inter-element correlation and to compute enrichment factors, making the proposed procedure particularly useful for investigating lead occurrence and pathways in fish bone tissues in order to find suitable biomarkers for the Antarctic marine environment.

  14. Determination of lead and zinc concentrations in the blood and liver of the captive common green iguana (Iguana iguana).

    Science.gov (United States)

    Burns, Russell P; Paul-Murphy, Joanne

    2009-09-01

    Heavy metal toxicosis is a well-known phenomenon in wild, captive-animal, and domestic animal medicine. However, the occurrence among reptiles is not well documented. One reason for this is the lack of information regarding reference blood and tissue levels of heavy metals in reptiles. To determine normal blood lead, plasma zinc, and liver lead and zinc concentrations, blood and liver samples were collected from 4 adult and 16 juvenile, healthy green iguanas (Iguana iguana). Lead and zinc levels were measured using atomic absorption spectroscopy. Using the mean +/- two SD as the normal reference range, the present study suggests the following for captive common green iguana: 1) whole blood lead level: 0.06 +/- 0.06 microg/ml; 2) plasma zinc level: 2.68 +/- 1.66 microg/ml; 3) liver lead level (wet-weight basis): <1.0 +/- 0.0 microg/g; 4) liver lead level (dry-weight basis): <3.0 +/- 0.0 microg/g; 5) liver zinc level (wet-weight basis): 24.9 +/- 11.6 microg/g; and 6) liver zinc level (dry-weight basis): 83.4 +/- 44.6 microg/g. These values are fairly consistent with published reference levels in other mammalian and avian species.

  15. Determination of internal radiation dose due to intake of polonium 210 and lead 210 via smoking

    International Nuclear Information System (INIS)

    Al-Masri, M. S.; Kharita, M.H.; Nashawati, A.; Amin, Y.; Al-Akel, B.

    2004-12-01

    In this study, 18 kind of cigarettes and five kinds of molasses consumed by Syrians were collected and analyzed for radioactivity in order to estimate the internal radiation dose caused by 210 Po and 210 Pb intake. Polonium 210 and lead 210 concentrations varied between 4 and 16.4 m Bq/cigarette, while 210 Po distribution ratios in different parts of consumed cigarette were %12, %73, %1.6 in ash, smoke and filter, respectively. In addition, annual intake of 210 Po by a main smoker was varied between 4.4 and 18 Bq/year assuming that the main smoker breathes about 15% of the total 210 Po present in tobacco. Using the values of the annual intake, annual equivalent radiation dose caused by smoking has reached 178 μSv/year. Moreover, mean concentration of 210 Po in nonsmokers and smokers bloods has reached 130 and 97 mBq/l, respectively, while the mean value of 210 Po concentration was relatively higher and reached 176 and 155 mBq/l in smokers and non smoker bloods, respectively (Authors)

  16. Radioactivity determination of sealed pure beta-sources by surface dose measurements and Monte Carlo simulations

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Chang Heon [Interdisciplinary Program in Radiation Applied Life Science, Seoul National University College of Medicine, Seoul (Korea, Republic of); Jung, Seongmoon [Program in Biomedical Radiation Sciences, Department of Transdisciplinary Studies, Graduate School of Convergence Science and Technology, Seoul National University, Seoul (Korea, Republic of); Choi, Kanghyuk; Son, Kwang-Jae; Lee, Jun Sig [Hanaro Applications Research, Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Ye, Sung-Joon, E-mail: sye@snu.ac.kr [Interdisciplinary Program in Radiation Applied Life Science, Seoul National University College of Medicine, Seoul (Korea, Republic of); Program in Biomedical Radiation Sciences, Department of Transdisciplinary Studies, Graduate School of Convergence Science and Technology, Seoul National University, Seoul (Korea, Republic of); Center for Convergence Research on Robotics, Advance Institutes of Convergence Technology, Seoul National University, Suwon (Korea, Republic of)

    2016-04-21

    This study aims to determine the activity of a sealed pure beta-source by measuring the surface dose rate using an extrapolation chamber. A conversion factor (cGy s{sup −1} Bq{sup −1}), which was defined as the ratio of surface dose rate to activity, can be calculated by Monte Carlo simulations of the extrapolation chamber measurement. To validate this hypothesis the certified activities of two standard pure beta-sources of Sr/Y-90 and Si/P-32 were compared with those determined by this method. In addition, a sealed test source of Sr/Y-90 was manufactured by the HANARO reactor group of KAERI (Korea Atomic Energy Research Institute) and used to further validate this method. The measured surface dose rates of the Sr/Y-90 and Si/P-32 standard sources were 4.615×10{sup −5} cGy s{sup −1} and 2.259×10{sup −5} cGy s{sup −1}, respectively. The calculated conversion factors of the two sources were 1.213×10{sup −8} cGy s{sup −1} Bq{sup −1} and 1.071×10{sup −8} cGy s{sup −1} Bq{sup −1}, respectively. Therefore, the activity of the standard Sr/Y-90 source was determined to be 3.995 kBq, which was 2.0% less than the certified value (4.077 kBq). For Si/P-32 the determined activity was 2.102 kBq, which was 6.6% larger than the certified activity (1.971 kBq). The activity of the Sr/Y-90 test source was determined to be 4.166 kBq, while the apparent activity reported by KAERI was 5.803 kBq. This large difference might be due to evaporation and diffusion of the source liquid during preparation and uncertainty in the amount of weighed aliquot of source liquid. The overall uncertainty involved in this method was determined to be 7.3%. We demonstrated that the activity of a sealed pure beta-source could be conveniently determined by complementary combination of measuring the surface dose rate and Monte Carlo simulations.

  17. Electrochemical determination of cadmium and lead on pristine single-walled carbon nanotube electrodes.

    Science.gov (United States)

    Bui, Minh-Phuong Ngoc; Li, Cheng Ai; Han, Kwi Nam; Pham, Xuan-Hung; Seong, Gi Hun

    2012-01-01

    A flexible, transparent, single-walled carbon nanotube (SWCNT) film electrode was prepared by vacuum filtering methods, followed by photolithographic patterning of a photoresist polymer on the SWCNT surface. The morphology of the SWCNT film electrode surface was characterized using a field-emission scanning electron microscope coupled to an energy-dispersive X-ray spectrophotometer. The electrodes were successfully used as a mercury-free electrochemical sensor for individual and simultaneous detection of cadmium (Cd(2+)) and lead (Pb(2+)) in 0.02 M HCl by square-wave stripping voltammetry. Some important operational parameters, including deposition time, deposition potential, square-wave amplitude, and square wave-frequency were optimized for the detection of Cd(2+) and Pb(2+). The newly developed sensor showed good linear behavior in the examined concentration. For individual Cd(2+) and Pb(2+) ion detection, the linear range was found from 0.033 to 0.228 ppm with detection limits of 0.7 ppb (R(2) = 0.985) for Cd(2+) and 0.8 ppb (R(2) = 0.999) for Pb(2+). For simultaneous detection, the linear range was found from 0.033 to 0.280 ppm with a limit of detection of 2.2 ppb (R(2) = 0.976) and 0.6 ppb (R(2) = 0.996) for Cd(2+) and Pb(2+), respectively. SWCNT film electrodes offered favorable reproducibility of ± 5.4% and 4.3% for Cd(2+) and Pb(2+), respectively. The experiments demonstrated the applicability of carbon nanotubes, specifically in the preparation of SWCNT films. The results suggest that the proposed flexible SWCNT film electrodes can be applied as simple, efficient, cost-effective, and/or disposable electrodes for simultaneous detection of heavy metal ions.

  18. Determination of the Absolute Disintegration Rate of Cs-137 sources by the Tracer Method

    Energy Technology Data Exchange (ETDEWEB)

    Hellstroem, S; Brune, D

    1963-07-15

    {sup 137}Cs - sources were absolutely measured by the 'tracer method', with {sup 82}Br as a tracer nuclide and with application of the 4{pi} {beta}-{gamma} coincidence technique. A self-absorption of 6 % was found in sources obtained from a solution with a carrier-content of 400 {mu}g/ml. The precision of the method for the determination of the {beta}-emission rate was estimated to {+-} 1 %. The results were compared with those of other works.

  19. A photon spectrometric dose-rate constant determination for the Advantage™ Pd-103 brachytherapy source

    OpenAIRE

    Chen, Zhe Jay; Bongiorni, Paul; Nath, Ravinder

    2010-01-01

    Purpose: Although several dosimetric characterizations using Monte Carlo simulation and thermoluminescent dosimetry (TLD) have been reported for the new Advantage™ Pd-103 source (IsoAid, LLC, Port Richey, FL), no AAPM consensus value has been established for the dosimetric parameters of the source. The aim of this work was to perform an additional dose-rate constant (Λ) determination using a recently established photon spectrometry technique (PST) that is independent of the published TLD and ...

  20. Determination of the Absolute Disintegration Rate of Cs-137 sources by the Tracer Method

    International Nuclear Information System (INIS)

    Hellstroem, S.; Brune, D.

    1963-07-01

    137 Cs - sources were absolutely measured by the 'tracer method', with 82 Br as a tracer nuclide and with application of the 4π β-γ coincidence technique. A self-absorption of 6 % was found in sources obtained from a solution with a carrier-content of 400 μg/ml. The precision of the method for the determination of the β-emission rate was estimated to ± 1 %. The results were compared with those of other works

  1. Alpha spectrometry of thick sources. I. Application to alpha emitters determination

    International Nuclear Information System (INIS)

    Acena, M.L.; Garcia-Torano, E.; Rivero, M.C.

    1977-01-01

    A method for determining alpha emitters by silicon surface barrier detector spectroscopy using thick sources is studied. Two types of spectra have been obtained. They have different shapes of line according to the procedure used for preparing the sources. For both spectra a computing least square programme has been developed. In this way it is possible to calculate line intensities with accuracy better than 20 percent. (author) [es

  2. 3-Mercaptopropyltrimethoxysilane Modified Diatomite: Preparation and Application for Voltammetric Determination of Lead (II and Cadmium (II

    Directory of Open Access Journals (Sweden)

    Dinh Quang Khieu

    2017-01-01

    Full Text Available In this study, functionalized diatomite was prepared by grafting of 3-mercaptopropyltrimethoxysilane (MPTMS to diatomite (MPTMS-diatomite. The diatomite with thermal treatment from 100 to 700°C was functionalized by MPTMS under dry and humid conditions. The obtained MPTMS-diatomite was characterized by X-ray diffraction (XRD, thermal gravity-differential scanning calorimeter (TG-DSC, and Fourier transformation infrared (FT-IR. The results showed that an increase in treatment temperature seems to reduce the loading of MPTMS onto diatomite. The humidity of diatomite was favorable for the grafting of functional groups on the surface. The possible mechanisms of MPTMS loading to diatomite (MPTMS-diatomite were also proposed. The performance of a carbon paste electrode (CPE modified with MPTMS-diatomite in the simultaneous determination of Cd(II and Pb(II ions was addressed.

  3. Source term determination from subcritical multiplication measurements at Koral-1 reactor

    International Nuclear Information System (INIS)

    Blazquez, J.B.; Barrado, J.M.

    1978-01-01

    By using an AmBe neutron source two independent procedures have been settled for the zero-power experimental fast-reactor Coral-1 in order to measure the source term which appears in the point kinetical equations. In the first one, the source term is measured when the reactor is just critical with source by taking advantage of the wide range of the linear approach to critical for Coral-1. In the second one, the measurement is made in subcritical state by making use of the previous calibrated control rods. Several applications are also included such as the measurement of the detector dead time, the determinations of the reactivity of small samples and the shape of the neutron importance of the source. (author)

  4. Source and impact of lead contamination on {delta}-aminolevulinic acid dehydratase activity in several marine bivalve species along the Gulf of Cadiz

    Energy Technology Data Exchange (ETDEWEB)

    Company, R.; Serafim, A.; Lopes, B.; Cravo, A. [CIMA, University of Algarve, Campus de Gambelas, 8005-139 Faro (Portugal); Kalman, J.; Riba, I.; DelValls, T.A. [Catedra UNESCO/UNITWIN/WiCop, Department of Physical-Chemistry, Faculty Marine and Environmental Sciences, University of Cadiz, 11510 Puerto Real, Cadiz (Spain); Blasco, J. [Instituto Ciencias Marinas Andalucia (CSIC), Campus Rio San Pedro, 11510 Puerto Real, Cadiz (Spain); Delgado, J. [Department of Geology, University of Huelva, Avda Fuerzas Armadas s/n, 21071 Huelva (Spain); Sarmiento, A.M. [Catedra UNESCO/UNITWIN/WiCop, Department of Physical-Chemistry, Faculty Marine and Environmental Sciences, University of Cadiz, 11510 Puerto Real, Cadiz (Spain); Department of Geology, University of Huelva, Avda Fuerzas Armadas s/n, 21071 Huelva (Spain); Nieto, J.M. [Department of Geology, University of Huelva, Avda Fuerzas Armadas s/n, 21071 Huelva (Spain); Shepherd, T.J.; Nowell, G. [Department of Earth Sciences, University of Durham, Science Laboratories, Durham DH1 3LE (United Kingdom); Bebianno, M.J., E-mail: mbebian@ualg.pt [CIMA, University of Algarve, Campus de Gambelas, 8005-139 Faro (Portugal)

    2011-01-17

    Coastal areas and estuaries are particularly sensitive to metal contamination from anthropogenic sources and in the last few decades the study of space-time distribution and variation of metals has been extensively researched. The Gulf of Cadiz is no exception, with several rivers draining one of the largest concentrations of sulphide deposits in the world, the Iberian Pyrite Belt (IPB). Of these rivers, the Guadiana, one of the most important in the Iberian Peninsula, together with smaller rivers like the Tinto and Odiel, delivers a very high metal load to the adjacent coastal areas. The purpose of this work was to study the source and impact of lead (Pb) drained from historical or active mining areas in the IPB on the activity of a Pb inhibited enzyme ({delta}-aminolevulinic acid dehydratase, ALAD) in several bivalve species along the Gulf of Cadiz. Seven marine species (Chamelea gallina, Mactra corallina, Donax trunculus, Cerastoderma edule, Mytilus galloprovincialis, Scrobicularia plana and Crassostrea angulata) were collected at 12 sites from Mazagon, near the mouth of the rivers Tinto and Odiel (Spain), to Cacela Velha (Ria Formosa lagoon system, Portugal). Lead concentrations, ALAD activity and lead isotope ratios ({sup 206}Pb/{sup 204}Pb, {sup 207}Pb/{sup 204}Pb and {sup 208}Pb/{sup 204}Pb) were determined in the whole soft tissues. The highest Pb concentrations were determined in S. plana (3.50 {+-} 1.09 {mu}g g{sup -1} Pb d.w.) and D. trunculus (1.95 {+-} 0.10 {mu}g g{sup -1} Pb d.w.), while M. galloprovincialis and C. angulata showed the lowest Pb levels (<0.38 {mu}g g{sup -1} Pb d.w.). In general, ALAD activity is negatively correlated with total Pb concentration. However this relationship is species dependent (e.g. linear for C. gallina ALAD = -0.36[Pb] + 0.79; r = 0.837; or exponential for M. galloprovincialis ALAD = 2.48e{sup -8.3[Pb]}; r = 0.911). This indicates that ALAD activity has considerable potential as a biomarker of Pb and moreover, in

  5. Determination of lead equivalent thickness to building blocks used in shielding of diagnostic x-ray rooms in Syria

    International Nuclear Information System (INIS)

    Kawash, A.; Khedr, M.; Wannus, K.; Souliman, J.; Al-Oudat, M.

    1998-06-01

    Lead equivalent thicknesses of various kinds of blocks (Hollow core, solid, filled, roof) with different thicknesses were determined. These blocks are widely used for building the diagnostic X-rya departments in Syria. Different applied voltages at X-ray tube (65, 85, 100, 125, 150 KVp) were examined. The results showed that the highest lead equivalent thicknesses for hollow core blocks were at 100 KVp. These equivalent thicknesses were 0.4372, 0.7008 and 0.928 mm for block thicknesses of 10, 15 and 20 cm, respectively. it was also found that, the lead equivalent thicknesses for filled, solid and concrete block were 3.5 to 4 times higher than that of the hollow core block for the same thicknesses and the applied KVp. Values obtained for roof blocks were similar to that of hollow core for the same conditions and geometry. (Author)

  6. Semi-empirical Determination of Detection Efficiency for Voluminous Source by Effective Solid Angle Method

    Energy Technology Data Exchange (ETDEWEB)

    Kang, M. Y.; Kim, J. H.; Choi, H. D. [Seoul National Univ., Seoul (Korea, Republic of); Sun, G. M. [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2014-05-15

    In the field of γ-ray measurements, the determination of full energy (FE) absorption peak efficiency for a voluminous sample is difficult, because the preparation of the certified radiation source with the same chemical composition and geometry for the original voluminous sample is not easy. In order to solve this inconvenience, simulation or semi-empirical methods are preferred in many cases. Effective Solid Angle (ESA) Code which includes semi-empirical approach has been developed by the Applied Nuclear Physics Group in Seoul National University. In this study, we validated ESA code by using Marinelli type voluminous KRISS (Korea Research Institute of Standards and Science) CRM (Certified Reference Materials) sources and IAEA standard γ-ray point sources. And semi-empirically determined efficiency curve for voluminous source by using the ESA code is compared with the experimental value. We calculated the efficiency curve of voluminous source from the measured efficiency of standard point source by using the ESA code. We will carry out the ESA code validation by measurement of various CRM volume sources with detector of different efficiency.

  7. A photon spectrometric dose-rate constant determination for the Advantage Pd-103 brachytherapy source

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Zhe Jay; Bongiorni, Paul; Nath, Ravinder [Department of Therapeutic Radiology, Yale University School of Medicine, New Haven, Connecticut 06520 (United States)

    2010-02-15

    Purpose: Although several dosimetric characterizations using Monte Carlo simulation and thermoluminescent dosimetry (TLD) have been reported for the new Advantage Pd-103 source (IsoAid, LLC, Port Richey, FL), no AAPM consensus value has been established for the dosimetric parameters of the source. The aim of this work was to perform an additional dose-rate constant ({Lambda}) determination using a recently established photon spectrometry technique (PST) that is independent of the published TLD and Monte Carlo techniques. Methods: Three Model IAPD-103A Advantage Pd-103 sources were used in this study. The relative photon energy spectrum emitted by each source along the transverse axis was measured using a high-resolution germanium spectrometer designed for low-energy photons. For each source, the dose-rate constant was determined from its emitted energy spectrum. The PST-determined dose-rate constant ({sub PST}{Lambda}) was then compared to those determined by TLD ({sub TLD}{Lambda}) and Monte Carlo ({sub MC}{Lambda}) techniques. A likely consensus {Lambda} value was estimated as the arithmetic mean of the average {Lambda} values determined by each of three different techniques. Results: The average {sub PST}{Lambda} value for the three Advantage sources was found to be (0.676{+-}0.026) cGyh{sup -1} U{sup -1}. Intersource variation in {sub PST}{Lambda} was less than 0.01%. The {sub PST}{Lambda} was within 2% of the reported {sub MC}{Lambda} values determined by PTRAN, EGSnrc, and MCNP5 codes. It was 3.4% lower than the reported {sub TLD}{Lambda}. A likely consensus {Lambda} value was estimated to be (0.688{+-}0.026) cGyh{sup -1} U{sup -1}, similar to the AAPM consensus values recommended currently for the Theragenics (Buford, GA) Model 200 (0.686{+-}0.033) cGyh{sup -1} U{sup -1}, the NASI (Chatsworth, CA) Model MED3633 (0.688{+-}0.033) cGyh{sup -1} U{sup -1}, and the Best Medical (Springfield, VA) Model 2335 (0.685{+-}0.033) cGyh{sup -1} U{sup -1} {sup 103}Pd

  8. A photon spectrometric dose-rate constant determination for the Advantage Pd-103 brachytherapy source

    International Nuclear Information System (INIS)

    Chen, Zhe Jay; Bongiorni, Paul; Nath, Ravinder

    2010-01-01

    Purpose: Although several dosimetric characterizations using Monte Carlo simulation and thermoluminescent dosimetry (TLD) have been reported for the new Advantage Pd-103 source (IsoAid, LLC, Port Richey, FL), no AAPM consensus value has been established for the dosimetric parameters of the source. The aim of this work was to perform an additional dose-rate constant (Λ) determination using a recently established photon spectrometry technique (PST) that is independent of the published TLD and Monte Carlo techniques. Methods: Three Model IAPD-103A Advantage Pd-103 sources were used in this study. The relative photon energy spectrum emitted by each source along the transverse axis was measured using a high-resolution germanium spectrometer designed for low-energy photons. For each source, the dose-rate constant was determined from its emitted energy spectrum. The PST-determined dose-rate constant ( PST Λ) was then compared to those determined by TLD ( TLD Λ) and Monte Carlo ( MC Λ) techniques. A likely consensus Λ value was estimated as the arithmetic mean of the average Λ values determined by each of three different techniques. Results: The average PST Λ value for the three Advantage sources was found to be (0.676±0.026) cGyh -1 U -1 . Intersource variation in PST Λ was less than 0.01%. The PST Λ was within 2% of the reported MC Λ values determined by PTRAN, EGSnrc, and MCNP5 codes. It was 3.4% lower than the reported TLD Λ. A likely consensus Λ value was estimated to be (0.688±0.026) cGyh -1 U -1 , similar to the AAPM consensus values recommended currently for the Theragenics (Buford, GA) Model 200 (0.686±0.033) cGyh -1 U -1 , the NASI (Chatsworth, CA) Model MED3633 (0.688±0.033) cGyh -1 U -1 , and the Best Medical (Springfield, VA) Model 2335 (0.685±0.033) cGyh -1 U -1 103 Pd sources. Conclusions: An independent Λ determination has been performed for the Advantage Pd-103 source. The PST Λ obtained in this work provides additional information

  9. SU-F-T-54: Determination of the AAPM TG-43 Brachytherapy Dosimetry Parameters for A New Titanium-Encapsulated Yb-169 Source by Monte Carlo Calculations

    Energy Technology Data Exchange (ETDEWEB)

    Reynoso, F [UT MD Anderson Cancer Center, Houston, TX (United States); Washington University School of Medicine, St. Louis, MO (United States); Munro, J [Source Production & Equipment Co., Inc., St. Rose, LA (United States); Cho, S [UT MD Anderson Cancer Center, Houston, TX (United States)

    2016-06-15

    Purpose: To determine the AAPM TG-43 brachytherapy dosimetry parameters of a new titanium-encapsulated Yb-169 source designed to maximize the dose enhancement during gold nanoparticle-aided radiation therapy (GNRT). Methods: An existing Monte Carlo (MC) model of the titanium-encapsulated Yb-169 source, which was described in the current investigators’ published MC optimization study, was modified based on the source manufacturer’s detailed specifications, resulting in an accurate model of the titanium-encapsulated Yb-169 source that was actually manufactured. MC calculations were then performed using the MCNP5 code system and the modified source model, in order to obtain a complete set of the AAPM TG-43 parameters for the new Yb-169 source. Results: The MC-calculated dose rate constant for the new titanium-encapsulated Yb-169 source was 1.05 ± 0.03 cGy per hr U, indicating about 10% decrease from the values reported for the conventional stainless steel-encapsulated Yb-169 sources. The source anisotropy and radial dose function for the new source were found similar to those reported for the conventional Yb-169 sources. Conclusion: In this study, the AAPM TG-43 brachytherapy dosimetry parameters of a new titanium-encapsulated Yb-169 source were determined by MC calculations. The current results suggested that the use of titanium, instead of stainless steel, to encapsulate the Yb-169 core would not lead to any major change in the dosimetric characteristics of the Yb-169 source, while it would allow more low energy photons being transmitted through the source filter thereby leading to an increased dose enhancement during GNRT. Supported by DOD/PCRP grant W81XWH-12-1-0198 This investigation was supported by DOD/PCRP grant W81XWH-12-1- 0198.

  10. Development of new reference materials for the determination of cadmium, chromium, mercury and lead in polycarbonate

    International Nuclear Information System (INIS)

    Lee, Kil Jae; Lee, Yeo Jin; Choi, Young Rak; Kim, Jeong Sook; Kim, Youn Sung; Heo, Soo Bong

    2013-01-01

    Highlights: ► RMs for the determination of Cd, Cr, Hg and Pb in polycarbonate were developed. ► Double ID-ICP-MS technique was used for characterization of candidate RMs. ► The certified values for the elements ranged from 51.7 to 1133 mg kg −1 . ► The relative expanded uncertainties were shown to be less than 5.4%. ► New RMs were found to be suitable for the RoHS compliant tests. - Abstract: Reference materials for quantitative determination of Cd, Cr, Hg and Pb in polycarbonate were developed. Reference materials with two concentration level of elements were prepared by adding appropriate amounts of chemicals to a blank polycarbonate base material. It was shown that ten bottles with triplicate analysis are enough to demonstrate the homogeneity of these candidate reference materials. The statistical results also showed no significant trends in both short-term stability test for four weeks and long-term stability test for twelve months. The certification of the four elements was carried out by isotope-dilution-inductively coupled plasma mass spectrometry (ID-ICP-MS) with microwave-assisted digestion. Certification of candidate reference materials in a single laboratory was confirmed with interlaboratory comparison participated by a certain number of well-recognized testing laboratories in Korea. The certified values and expanded uncertainties (k = 2) for the candidate reference material with low level and the one with high level were (51.7 ± 2.1) mg kg −1 Cd, (103.8 ± 2.9) mg kg −1 Cd, (98.8 ± 4.5) mg kg −1 Cr, (1004 ± 49.8) mg kg −1 Cr, (107.4 ± 4.6) mg kg −1 Hg, (1133 ± 50.7) mg kg −1 Hg, (94.8 ± 3.7) mg kg −1 Pb and (988.4 ± 53.6) mg kg −1 Pb, respectively. The reference materials developed in this study demonstrated their suitability for the quality assurance in Cd, Cr, Hg and Pb analysis for the implementation of RoHS Directive.

  11. Development of a technique for the determination of lead and bromine in atmospheric particles by X-ray fluorescence

    Science.gov (United States)

    Sturges, W. T.; Harrison, Roy M.; Dams, R.

    A methodology has been developed for determining the lead and bromine content of atmospheric particles collected on membrane filters. In a novel calibration procedure, standards were prepared by drying fine precipitates of lead molybdate and silver bromide on to filters. Such standards were evidently free from bromine loss during analysis and storage, and more accurately represent real samples than conventional solution-impregnated filters. Elemental loadings in the range 0.1-10μg could be measured. Inhomogeneous efficiency of detection across the surface of samples was noted, and was accounted for by applying correction factors obtained from an intercomparison of XRF and atomic absorption analyses. Good comparability between Br determinations by XRF and neutron activation analysis was found. Problems of noncomparability between standards and samples of low concentration were noted in some cases.

  12. Determination of lead in water by electrothermal atomic absorption spectrometry with a nickel(II)-ammonium tartrate modifier

    International Nuclear Information System (INIS)

    Sekerka, I.; Lechner, J.F.

    1991-01-01

    A method is described for the determination of low concentrations of lead in water samples. Atomic absorption spectrometry is used with a tungsten ribbon furnace and Zeeman background correction. Interferences are eliminated by the addition of ammonium tartrate and nickel(II) nitrate to the samples to act as a matrix modifier and adjust the pH. The results show the superior performance of this modifier over other types used conventionally. The detection limit is 1 μg l -1 relative standard deviation of -1 can be obtained. The instrumentation is simple and the method is efficient for the determination of lead in various water samples. 25 refs.; 7 figs.; 6 tabs

  13. X-ray fluorescence determination of Sn, Sb, Pb in lead-based bearing alloys using a solution technique

    Science.gov (United States)

    Tian, Lunfu; Wang, Lili; Gao, Wei; Weng, Xiaodong; Liu, Jianhui; Zou, Deshuang; Dai, Yichun; Huang, Shuke

    2018-03-01

    For the quantitative analysis of the principal elements in lead-antimony-tin alloys, directly X-ray fluorescence (XRF) method using solid metal disks introduces considerable errors due to the microstructure inhomogeneity. To solve this problem, an aqueous solution XRF method is proposed for determining major amounts of Sb, Sn, Pb in lead-based bearing alloys. The alloy samples were dissolved by a mixture of nitric acid and tartaric acid to eliminated the effects of microstructure of these alloys on the XRF analysis. Rh Compton scattering was used as internal standard for Sb and Sn, and Bi was added as internal standard for Pb, to correct for matrix effects, instrumental and operational variations. High-purity lead, antimony and tin were used to prepare synthetic standards. Using these standards, calibration curves were constructed for the three elements after optimizing the spectrometer parameters. The method has been successfully applied to the analysis of lead-based bearing alloys and is more rapid than classical titration methods normally used. The determination results are consistent with certified values or those obtained by titrations.

  14. Determination of lead in environmental waters with dispersive liquid-liquid microextraction prior to atomic fluorescence spectrometry

    International Nuclear Information System (INIS)

    Zhou, Qingxiang; Zhao, Na; Xie, Guohong

    2011-01-01

    This paper established a new, rapid and sensitive method for the determination of lead in water samples preconcentrated by dispersive liquid-liquid microextraction (DLLME) prior to atomic fluorescence spectrometry. Dithizone was used as the chelating agent. In the DLLME procedure, lead formed lead-dithizone complex and migrated into the carbon tetrachloride micro-droplets. Important factors that would affect the extraction efficiency had been investigated including the kind and volume of extraction solvent and dispersive solvent, sample pH, the amount of chelating agent, extraction time and centrifugation time. The results showed that the coexisting ions containing in water samples had no obvious negative effect on the determination of lead. The experimental results indicated that the proposed method had a good linear range of 0.01-100 ng mL -1 (r 2 = 0.9990). The precision was 2.12% (RSD, n = 7) and the detection limit was 0.95 ng L -1 . Proposed method was validated with four real environmental samples and the results indicated that the proposed method was excellent for the future use and satisfied spiked recoveries were in the range of 92.9-97.4%.

  15. Lead Determination and Heterogeneity Analysis in Soil from a Former Firing Range

    Science.gov (United States)

    Urrutia-Goyes, Ricardo; Argyraki, Ariadne; Ornelas-Soto, Nancy

    2017-07-01

    Public places can have an unknown past of pollutants deposition. The exposition to such contaminants can create environmental and health issues. The characterization of a former firing range in Athens, Greece will allow its monitoring and encourage its remediation. This study is focused on Pb contamination in the site due to its presence in ammunition. A dense sampling design with 91 location (10 m apart) was used to determine the spatial distribution of the element in the surface soil of the study area. Duplicates samples were also collected one meter apart from 8 random locations to estimate the heterogeneity of the site. Elemental concentrations were measured using a portable XRF device after simple sample homogenization in the field. Robust Analysis of Variance showed that the contributions to the total variance were 11% from sampling, 1% analytical, and 88% geochemical; reflecting the suitability of the technique. Moreover, the extended random uncertainty relative to the mean concentration was 91.5%; confirming the high heterogeneity of the site. Statistical analysis defined a very high contamination in the area yielding to suggest the need for more in-depth analysis of other contaminants and possible health risks.

  16. In situ determination of the effects of lead and copper on cyanobacterial populations in microcosms.

    Directory of Open Access Journals (Sweden)

    Mireia Burnat

    Full Text Available BACKGROUND: Biomass has been studied as biomarker to evaluate the effect of heavy metals on microbial communities. Nevertheless, the most important methodological problem when working with natural and artificial microbial mats is the difficulty to evaluate changes produced on microorganism populations that are found in thicknesses of just a few mm depth. METHODOLOGY/PRINCIPAL FINDINGS: Here, we applied for first time a recently published new method based on confocal laser scanning microscopy and image-program analysis to determine in situ the effect of Pb and Cu stress in cyanobacterial populations. CONCLUSIONS/SIGNIFICANCE: The results showed that both in the microcosm polluted by Cu and by Pb, a drastic reduction in total biomass for cyanobacterial and Microcoleus sp. (the dominant filamentous cyanobacterium in microbial mats was detected within a week. According to the data presented in this report, this biomass inspection has a main advantage: besides total biomass, diversity, individual biomass of each population and their position can be analysed at microscale level. CLSM-IA could be a good method for analyzing changes in microbial biomass as a response to the addition of heavy metals and also to other kind of pollutants.

  17. In situ determination of the effects of lead and copper on cyanobacterial populations in microcosms.

    Science.gov (United States)

    Burnat, Mireia; Diestra, Elia; Esteve, Isabel; Solé, Antonio

    2009-07-10

    Biomass has been studied as biomarker to evaluate the effect of heavy metals on microbial communities. Nevertheless, the most important methodological problem when working with natural and artificial microbial mats is the difficulty to evaluate changes produced on microorganism populations that are found in thicknesses of just a few mm depth. Here, we applied for first time a recently published new method based on confocal laser scanning microscopy and image-program analysis to determine in situ the effect of Pb and Cu stress in cyanobacterial populations. The results showed that both in the microcosm polluted by Cu and by Pb, a drastic reduction in total biomass for cyanobacterial and Microcoleus sp. (the dominant filamentous cyanobacterium in microbial mats) was detected within a week. According to the data presented in this report, this biomass inspection has a main advantage: besides total biomass, diversity, individual biomass of each population and their position can be analysed at microscale level. CLSM-IA could be a good method for analyzing changes in microbial biomass as a response to the addition of heavy metals and also to other kind of pollutants.

  18. Determination of the chemical yield on the Fricke dosimetry for 192Ir sources used in brachytherapy

    International Nuclear Information System (INIS)

    David, M.G.; Albuquerque, M.A.G.; Almeida, C.E. de; Rosado, P.H.

    2015-01-01

    With the aim of developing a primary standard for the absorbed dose to water, for the 192 Ir sources used in high dose rate brachytherapy, this work focuses on the determination of the chemical yield, G(Fe +3 ), using Fricke dosimetry, for the energy of those sources . The G(Fe +3 ) were determined the for three qualities of x-ray beams (150, 250 and 300 kV ) and for 60 Co energy. The G(Fe +3 ) value for the average energy of 192 Ir was obtained by linear fit, the found value was 1,555 ± 0,015 μmol/J. (author)

  19. Graphene oxide sheets immobilized polystyrene for column preconcentration and sensitive determination of lead by flame atomic absorption spectrometry.

    Science.gov (United States)

    Islam, Aminul; Ahmad, Hilal; Zaidi, Noushi; Kumar, Suneel

    2014-08-13

    A novel solid-phase extractant was synthesized by coupling graphene oxide (GO) on chloromethylated polystyrene through an ethylenediamine spacer unit to develop a column method for the preconcentration/separation of lead prior to its determination by flame atomic absorption spectrometry. It was characterized by Fourier transform infrared spectroscopy, far-infrared spectroscopy, thermogravimetric analysis/differential thermal analysis, scanning electron microscopy, energy-dispersive spectrometry, and transmission electron microscopy. The abundant oxygen-containing surface functional groups form a strong complex with lead, resulting in higher sorption capacity (227.92 mg g(-1)) than other nanosorbents used for sorption studies of the column method. Using the column procedure here is an alternative to the direct use of GO, which restricts irreversible aggregation of GO and its escape into the ecosystem, making it an environmentally sustainable method. The column method was optimized by varying experimental variables such as pH, flow rate for sorption/desorption, and elution condition and was observed to exhibit a high preconcentration factor (400) with a low preconcentration limit (2.5 ppb) and a high degree of tolerance for matrix ions. The accuracy of the proposed method was verified by determining the Pb content in the standard reference materials and by recovery experiments. The method showed good precision with a relative standard deviation <5%. The proposed method was successfully applied for the determination of lead in tap water, electroplating wastewater, river water, and food samples after preconcentration.

  20. Experimental and theoretical determination of dosimetric characteristics of IsoAid ADVANTAGETM125I brachytherapy source

    International Nuclear Information System (INIS)

    Meigooni, Ali S.; Hayes, Joshua L.; Zhang Hualin; Sowards, Keith

    2002-01-01

    125 I brachytherapy sources are being used for interstitial implants in tumor sites such as the prostate. Recently, the ADVANTAGE TM 125 I, Model IAI-125, source became commercially available for interstitial brachytherapy treatment. Dosimetric characteristics (dose rate constant, radial dose function, and anisotropy function) of this source were experimentally and theoretically determined, following the AAPM Task Group 43 recommendations. Derivation of the dose rate constant was based on recent NIST WAFAC calibration performed in accordance with their 1999 standard. Measurements were performed in Solid Water TM phantom using LiF thermoluminescent dosimeters. The theoretical calculations were performed in both Solid Water TM and water using the PTRAN Monte Carlo code. The results indicated that a dose rate constant of the new source in water was 0.98±0.03 cGy h -1 U -1 . The radial dose function of the new source was measured in Solid Water TM and calculated both in water and Solid Water TM at distances up to 10.0 cm. The anisotropy function, F(r,θ), of the new source was measured and calculated in Solid Water TM at distances of 2 cm, 3 cm, 5 cm, and 7 cm and also was calculated in water at distances ranging from 1 cm to 7 cm from the source. From the anisotropy function, the anisotropy factors and anisotropy constant were derived. The anisotropy constant of the ADVANTAGE TM 125 I source in water was found to be 0.97±0.03. The dosimetric characteristics of this new source compared favorably with those from the Amersham Health Model 6711 source. Complete dosimetric parameters of the new source are presented in this paper

  1. Lead isotope ratios in artists' lead white: a progress report

    Energy Technology Data Exchange (ETDEWEB)

    Keisch, B; Callahan, R C [Carnegie-Mellon Univ., Pittsburgh, Pa. (USA)

    1976-07-01

    The lead isotope ratios in over four hundred samples of lead white have been determined. The samples represent various geographical sources and dates from the thirteenth century to the present. A new method for organizing this large volume of data is described which helps with the visualization of temporal and geographic patterns. A number of interesting relationships between lead isotope ratio and date or source are shown to exist. Some examples of successful applications of this methodology are described.

  2. Lead isotope ratios in artists' lead white: a progress report

    International Nuclear Information System (INIS)

    Keisch, B.; Callahan, R.C.

    1976-01-01

    The lead isotope ratios in over four hundred samples of lead white have been determined. The samples represent various geographical sources and dates from the thirteenth century to the present. A new method for organizing this large volume of data is described which helps with the visualization of temporal and geographic patterns. A number of interesting relationships between lead isotope ratio and date or source are shown to exist. Some examples of successful applications of this methodology are described. (author)

  3. Isotopic signatures suggest important contributions from recycled gasoline, road dust and non-exhaust traffic sources for copper, zinc and lead in PM10 in London, United Kingdom

    Science.gov (United States)

    Dong, Shuofei; Ochoa Gonzalez, Raquel; Harrison, Roy M.; Green, David; North, Robin; Fowler, Geoff; Weiss, Dominik

    2017-09-01

    The aim of this study was to improve our understanding of what controls the isotope composition of Cu, Zn and Pb in particulate matter (PM) in the urban environment and to develop these isotope systems as possible source tracers. To this end, isotope ratios (Cu, Zn and Pb) and trace element concentrations (Fe, Al, Cu, Zn, Sb, Ba, Pb, Cr, Ni and V) were determined in PM10 collected at two road sites with contrasting traffic densities in central London, UK, during two weeks in summer 2010, and in potential sources, including non-combustion traffic emissions (tires and brakes), road furniture (road paint, manhole cover and road tarmac surface) and road dust. Iron, Ba and Sb were used as proxies for emissions derived from brake pads, and Ni, and V for emissions derived from fossil fuel oil. The isotopic composition of Pb (expressed using 206Pb/207Pb) ranged between 1.1137 and 1.1364. The isotope ratios of Cu and Zn expressed as δ65CuNIST976 and δ66ZnLyon ranged between -0.01‰ and +0.51‰ and between -0.21‰ and +0.33‰, respectively. We did not find significant differences in the isotope signatures in PM10 over the two weeks sampling period and between the two sites, suggesting similar sources for each metal at both sites despite their different traffic densities. The stable isotope composition of Pb suggests significant contribution from road dust resuspension and from recycled leaded gasoline. The Cu and Zn isotope signatures of tires, brakes and road dust overlap with those of PM10. The correlation between the enrichments of Sb, Cu, Ba and Fe in PM10 support the previously established hypothesis that Cu isotope ratios are controlled by non-exhaust traffic emission sources in urban environments (Ochoa Gonzalez et al., 2016). Analysis of the Zn isotope signatures in PM10 and possible sources at the two sites suggests significant contribution from tire wear. However, temporary additional sources, likely high temperature industrial emissions, need to be invoked

  4. Lead isotopes combined with a sequential extraction procedure for source apportionment in the dry deposition of Asian dust and non-Asian dust

    International Nuclear Information System (INIS)

    Lee, Pyeong-Koo; Yu, Soonyoung

    2016-01-01

    Lead isotopic compositions were determined in leachates that were generated using sequential extractions of dry deposition samples of Asian dust (AD) and non-Asian dust (NAD) and Chinese desert soils, and used to apportion Pb sources. Results showed significant differences in "2"0"6Pb/"2"0"7Pb and "2"0"6Pb/"2"0"4Pb isotopic compositions in non-residual fractions between the dry deposition samples and the Chinese desert soils while "2"0"6Pb/"2"0"7Pb and "2"0"6Pb/"2"0"4Pb isotopic compositions in residual fraction of the dry deposition of AD and NAD were similar to the mean "2"0"6Pb/"2"0"7Pb and "2"0"6Pb/"2"0"4Pb in residual fraction of the Alashan Plateau soil. These results indicate that the geogenic materials of the dry deposition of AD and NAD were largely influenced by the Alashan Plateau soil, while the secondary sources of the dry deposition were different from those of the Chinese desert soils. In particular, the lead isotopic compositions in non-residual fractions of the dry deposition were homogenous, which implies that the non-residual four fractions (F1 to F4) shared the primary anthropogenic origin. "2"0"6Pb/"2"0"7Pb values and the predominant wind directions in the study area suggested that airborne particulates of heavily industrialized Chinese cities were one of the main Pb sources. Source apportionment calculations showed that the average proportion of anthropogenic Pb in the dry deposition of AD and NAD was 87% and 95% respectively in total Pb extraction, 92% and 97% in non-residual fractions, 15% and 49% in residual fraction. Approximately 81% and 80% of the anthropogenic Pb was contributed by coal combustion in China in the dry deposition of AD and NAD respectively while the remainder was derived from industrial Pb contamination. The research result proposes that sequential extractions with Pb isotope analysis are a useful tool for the discrimination of anthropogenic and geogenic origins in highly contaminated AD and NAD. - Highlights:

  5. Relationship between the pitch of modulation collimators and the determination accuracy of source positions

    International Nuclear Information System (INIS)

    Fujii, Masami; Nishimura, Jun

    1989-01-01

    The celestial positions of X-ray bursters and gamma-ray burst sources can be accurately determined with rotating modulation collimators which possess wide fields of view and also high angular resolutions. Since the determination accuracy is dependent on the signal to noise ratio of incident photons, the distribution of signal power is analysed and the optimum pitch of the modulation collimator for a burst of a given size is discussed. (author)

  6. Preliminary PM2.5 and PM10 fractions source apportionment complemented by statistical accuracy determination

    Directory of Open Access Journals (Sweden)

    Samek Lucyna

    2016-03-01

    Full Text Available Samples of PM10 and PM2.5 fractions were collected between the years 2010 and 2013 at the urban area of Krakow, Poland. Numerous types of air pollution sources are present at the site; these include steel and cement industries, traffic, municipal emission sources and biomass burning. Energy dispersive X-ray fluorescence was used to determine the concentrations of the following elements: Cl, K, Ca, Ti, Mn, Fe, Ni, Cu, Zn, Br, Rb, Sr, As and Pb within the collected samples. Defining the elements as indicators, airborne particulate matter (APM source profiles were prepared by applying principal component analysis (PCA, factor analysis (FA and multiple linear regression (MLR. Four different factors identifying possible air pollution sources for both PM10 and PM2.5 fractions were attributed to municipal emissions, biomass burning, steel industry, traffic, cement and metal industry, Zn and Pb industry and secondary aerosols. The uncertainty associated with each loading was determined by a statistical simulation method that took into account the individual elemental concentrations and their corresponding uncertainties. It will be possible to identify two or more sources of air particulate matter pollution for a single factor in case it is extremely difficult to separate the sources.

  7. Determination of noise sources and space-dependent reactor transfer functions from measured output signals only

    Energy Technology Data Exchange (ETDEWEB)

    Hoogenboom, J.E.; van Dam, H.; Kleiss, E.B.J.; van Uitert, G.C.; Veldhuis, D.

    1982-01-01

    The measured cross power spectral densities of the signals from three neutron detectors and the displacement of the control rod of the 2 MW research reactor HOR at Delft have been used to determine the space-dependent reactor transfer function, the transfer function of the automatic reactor control system and the noise sources influencing the measured signals. From a block diagram of the reactor with control system and noise sources expressions were derived for the measured cross power spectral densities, which were adjusted to satisfy the requirements following from the adopted model. Then for each frequency point the required transfer functions and noise sources could be derived. The results are in agreement with those of autoregressive modelling of the reactor control feed-back loop. A method has been developed to determine the non-linear characteristics of the automatic reactor control system by analysing the non-gaussian probability density function of the power fluctuations.

  8. Determination of noise sources and space-dependent reactor transfer functions from measured output signals only

    International Nuclear Information System (INIS)

    Hoogenboom, J.E.

    1982-01-01

    The measured cross power spectral densities of the signals from three neutron detectors and the displacement of the control rod of the 2 MW research reactor HOR at Delft have been used to determine the space-dependent reactor transfer function, the transfer function of the automatic reactor control system and the noise sources influencing the measured signals. From a block diagram of the reactor with control system and noise sources expressions were derived for the measured cross power spectral densities, which were adjusted to satisfy the requirements following from the adopted model. Then for each frequency point the required transfer functions and noise sources could be derived. The results are in agreement with those of autoregressive modelling of the reactor control feed-back loop. A method has been developed to determine the non-linear characteristics of the automatic reactor control system by analysing the non-gaussian probability density function of the power fluctuations. (author)

  9. Determination of void fraction from source range monitor and mass flow rate data

    International Nuclear Information System (INIS)

    McCormick, R.D.

    1986-09-01

    This is a report on the calculation of the TMI-2 primary coolant system local void fraction from source range neutron flux monitor data and from hot leg mass flowrate meter data during the first 100 minutes of the accident. The methods of calculation of void fraction from the two data sources is explained and the results are compared. It is indicated that the void fraction determined using the mass flowrate data contained an error of unknown magnitude due to the assumption of constant homogeneous volumetric flowrate used in the calculation and required further work. Void fraction determined from the source range monitor data is felt to be usable although an uncertainty analysis has not been performed

  10. Determination of cadmium and lead species and phytochelatins in pea (Pisum sativum) by HPLC-ICPMS and HPLC-ESIMSn

    International Nuclear Information System (INIS)

    Baralkiewicz, D.; Magorzata, K.; Piechalak, A.; Tomaszewska, B.

    2009-01-01

    Full text: Trace elements play an important role in the functioning of life on our planet. Some of them can be highly toxic, whereas others can be essential. These effects are very often related to particular form in which the element is present. Often these different chemical forms of a particular element or its compounds are referred to as 'species'. Cadmium and lead are widespread heavy metal pollutants released into the environment by human activities. The presence of Pb 2+ and Cd 2+ in the environment leads to a numerous disturbances in many metabolic processes in plants. Inhibition of growth is a major symptom. Hyphenated techniques, such as HPLC-ICPMS and HPLC-ESIMSn seem to be the best analytical instruments to study metal speciation in plants. In our study, we used hyphenated techniques to identify compounds engaged in Cd and Pb metabolism and to perform analysis of metal complexes induced in Pisum sativum exposed to cadmium and lead. These identified compounds might be valuable source of information to study metal accumulation mechanism for bioremediation processes. (author)

  11. Open-Source Low-Cost Wireless Potentiometric Instrument for pH Determination Experiments

    Science.gov (United States)

    Jin, Hao; Qin, Yiheng; Pan, Si; Alam, Arif U.; Dong, Shurong; Ghosh, Raja; Deen, M. Jamal

    2018-01-01

    pH determination is an essential experiment in many chemistry laboratories. It requires a potentiometric instrument with extremely low input bias current to accurately measure the voltage between a pH sensing electrode and a reference electrode. In this technology report, we propose an open-source potentiometric instrument for pH determination…

  12. Demographic Information Sources and Utilization as Determinants of Educational Policy Making in South Western Nigeria

    Science.gov (United States)

    Gbadamosi, Belau Olatunde

    2013-01-01

    The paper examines demographic information sources and utilization as determinants of educational policy making in South West Nigeria. Using validated and structured questionnaire, the study population of 398 officers in the ministries of education in the affected states were enumerated. The study establishes population census, vital registration,…

  13. Determination of air kerma standard of high dose rate 192Ir brachytherapy source

    International Nuclear Information System (INIS)

    Pires, E.J.; Alves, C.F.E.; Leite, S.P.; Magalhaes, L.A.G.; David, M.G.; Almeida, C.E. de

    2015-01-01

    This paper presents the methodology developed by the Laboratorio de Ciencias Radiologicas and presently in use for determining of the air kerma standard of 192 Ir high dose rate sources to calibrate well-type chambers. Uncertainty analysis involving the measurements procedure are presented. (author)

  14. Standard test method for graphite furnace atomic absorption spectrometric determination of lead and cadmium extracted from ceramic foodware

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2000-01-01

    1.1 This test method covers procedures for using graphite furnace atomic absorption spectroscopy (GFAAS) to quantitatively determine lead and cadmium extracted by acetic acid at room temperature from the food-contact surface of foodware. The method is applicable to food-contact surfaces composed of silicate-based materials (earthenware, glazed ceramicware, decorated ceramicware, decorated glass, and lead crystal glass) and is capable of determining lead concentrations greater than 0.005 to 0.020 g/mL and cadmium concentrations greater than 0.0005 to 0.002 g/mL, depending on instrument design. 1.2 This test method also describes quality control procedures to check for contamination and matrix interference during GFAAS analyses and a specific sequence of analytical measurements that demonstrates proper instrument operation during the time period in which sample solutions are analyzed. 1.3 Cleaning and other contamination control procedures are described in this test method. Users may modify contamination cont...

  15. A binderless, covalently bulk modified electrochemical sensor: Application to simultaneous determination of lead and cadmium at trace level

    Energy Technology Data Exchange (ETDEWEB)

    Gunigollahalli Kempegowda, Raghu [Department of Studies in Chemistry, Bangalore University, Central College Campus, Bangalore 560001 (India); Malingappa, Pandurangappa, E-mail: mprangachem@gmail.com [Department of Studies in Chemistry, Bangalore University, Central College Campus, Bangalore 560001 (India)

    2012-05-30

    Highlights: Black-Right-Pointing-Pointer Proposed sensor is a new type of binderless covalent bulk modified electrode. Black-Right-Pointing-Pointer Surface can be easily renewed by simple mechanical polishing using emery sheets. Black-Right-Pointing-Pointer Free from modifier leaching during electrochemical measurements. Black-Right-Pointing-Pointer Provides long term storage stability with good reproducibility. Black-Right-Pointing-Pointer Nanomolar level detection limit achieved with selectivity. - Abstract: A new type of covalent binderless bulk modified electrode has been fabricated and used in the simultaneous determination of lead and cadmium ions at nanomolar level. The modification of graphitic carbon with 4-amino salicylic acid was carried out under microwave irradiation through the amide bond formation. The electrochemical behavior of the fabricated electrode has been carried out to decipher the interacting ability of the functional moieties present on the modifier molecules toward the simultaneous determination of Pb{sup 2+} and Cd{sup 2+} ions using cyclic and differential pulse anodic stripping voltammetry. The possible mode of interaction of functional groups with metal ions is proposed based on the pKa values of the modifier functionalities present on the surface of graphitic carbon particles. The analytical utility of the proposed sensor has been validated by measuring the lead and cadmium content from pretreated waste water samples of lead acid batteries.

  16. Heavy Metals (Mercury, Lead and Cadmium Determination in 17 Species of Fish Marketed in Khorramabad City, West of Iran

    Directory of Open Access Journals (Sweden)

    Ali Mortazavi

    2016-01-01

    Full Text Available Heavy metals entrance to fish body tissues and transferring to human body systems after their consuming makes numerous undesirable effects and health problems. The aim of this study was to determine some heavy metals (lead, cadmium and mercury in fresh fishes marketed in Khorramabad City, west of Iran. In this descriptive study, five samples of 17 fish species with high consumption were purchased randomly in 2014. Measurement of mercury, lead and cadmium was performed using atomic absorption spectrometry. All measurements were performed three times for each sample. Lead mean levels in fish samples was in the range 0.736 -1.005 ppm, cadmium range was from 0.196 to 0.015 ppm and mean content of mercury was  0.431 - 0.107 ppm. At present mean concentration of lead, mercury and cadmium in supplied fishes muscle is lower than maximum recommended levels according to WHO, EC and FDA guidelines. Based on the obtained results of this study and the importance of heavy metals in foods and their impacts on human health, continuous monitoring of heavy metals levels in foods is necessary.

  17. The determination of 800 to 30 μg lead(II) by potentiometric titration with molybdate

    International Nuclear Information System (INIS)

    Campiglio, A.

    1985-01-01

    The determination of 800 to 30 μg Pb(II) by potentiometric titration with molybdate by using a lead(II)-selective electrode was investigated. Under suitable conditions, 800 to 300 μg Pb(II) in aqueous solution by automatic or manual titration with 4x10 -3 M molybdate can be determined with an accuracy of +-0.57% and +-0.45% and a precision of +-0.43% and 0.30% (standard deviation = 0.25% and 0.17%, resp.). For determining amounts of Pb(II) below 300 μg, a 2x10 -3 M molybdate solution has to be used. Although 300 to 100μg Pb(II) are determinable again in water with satisfactory results, the titration in 40% ethanol is however more reliable: in this medium, amounts of 300 to 30μg Pb(II) can be determined with an accuracy of +-1% and a precision of +-2% (standard deviation from 20 titrations of 100μg Pb(II)=0.60%). The titration of 300-800μg Pb(II) in water and of 30-300μg Pb(II) in 40% ethanol is also possible in 0.1 M NaNO 3 sub- snd 0.1 M NaClO 4 sub- medium and can be used in the lead determination in organic compounds after mineralization with HNO 3 sub-HClO 4 sub-H 2 O 2 . (Author)

  18. Determination of factors through Monte Carlo method for Fricke dosimetry from 192Ir sources for brachytherapy

    International Nuclear Information System (INIS)

    David, Mariano Gazineu; Salata, Camila; Almeida, Carlos Eduardo

    2014-01-01

    The Laboratorio de Ciencias Radiologicas develops a methodology for the determination of the absorbed dose to water by Fricke chemical dosimetry method for brachytherapy sources of 192 Ir high dose rate and have compared their results with the laboratory of the National Research Council Canada. This paper describes the determination of the correction factors by Monte Carlo method, with the Penelope code. Values for all factors are presented, with a maximum difference of 0.22% for their determination by an alternative way. (author)

  19. Sources of dissolved mine drainage and atmospheric transported lead: A comparative case study in Japan and Sweden

    International Nuclear Information System (INIS)

    Aberg, Goeran; Satake, Kenichi

    2009-01-01

    A comparative case study in Naganobori Japan and Falun Sweden of runoff water from copper mines shows that the water and its particulates, filtered with a cutoff of 0.45 μm, have different lead isotope ratios pointing to different origins for the lead. While the larger particles have a lead ratio indicative of the atmospheric anthropogenic pollution the soluble lead has that of the copper ores. The domestic atmospheric lead ratio in Japan is homogeneous and characteristic of emissions from the incineration of waste. Lead pollution transported from the Asian continent by westerly winds can be distinguished from the Japanese pollution by its more thorogenic lead ratios, in for example analyses of copper moss from Naganobori.

  20. Experimental determination of the distribution coefficient (Kd) of lead and barium in soils of semiarid region of Bahia, Brazil

    International Nuclear Information System (INIS)

    Santos, Mariana M.; Fernandes, Heloisa H.F; Pontedeiro, Elizabeth M.; Su, Jian

    2013-01-01

    To determine the concentration of heavy metals and other contaminants in soils, aimed at evaluating the environmental impact, the use of the distribution coefficient is required (Kd), defined as the relationship between the concentrations adsorbed and in solution. The objective of this study was to determine the rates for the Lead and Barium metals in soil collected in Caetite, the state of Bahia, in two different depths. The importance of determining the distribution coefficient lies in the fact that being performed using a tropical soil. For the isotherms of Kd was used batch test method by adsorption to obtain the final concentrations. The first step was to determine the best ratio soil: solution obtained after equilibration time and finally the equilibrium concentration of the contaminant. Were also calculated percentages of the metal adsorbed by the soil and the amount of solute by the adsorbent. With the values obtained in experiments and using Mathematica 8.0 software, were made graphics equilibrium concentration versus quantity adsorbed (C vs. S). It can also plot isotherms for different models of Kd: linear, Langmuir and Freundlich in order to determine which adsorption model would fit best to the measured data and thus determine the distribution coefficient of the metal in the soil analyzed. The Freundlich isotherm was better adapted to the points of the two metals in both soils

  1. Determination of lead in red wine for CCQM-K30 international comparison by using ID-ICPMS

    International Nuclear Information System (INIS)

    Zhou Tao; Wang Jun; Lu Hai; Zhao Motian

    2007-01-01

    The content of lead in red wine for CCQM-K30 international key comparison is determined by using isotope dilution mass spectrometry (IDMS). This test almost reach detect limit of the method because the content of lead in red wine was only 3 ng/g and the procedure blank was about 0.3 ng. The comparison results indicate that it is easy to achieve agreements using IDMS. In uncertainty analysis, all of the factors about IDMS method were considered. But, procedure blank took great inference to experiment precision and enlarged the total uncertainty. Therefore the controls of procedure blank were very important for the analysis of ultra-trace concentration of samples. (authors)

  2. Particulate-bound polycyclic aromatic hydrocarbon sources and determinants in residential homes.

    Science.gov (United States)

    Cattaneo, Andrea; Fermo, Paola; Urso, Patrizia; Perrone, Maria Grazia; Piazzalunga, Andrea; Tarlassi, Jessica; Carrer, Paolo; Cavallo, Domenico Maria

    2016-11-01

    Human exposure to polycyclic aromatic hydrocarbons (PAHs) in indoor environments can be particularly relevant because people spend most of their time inside buildings, especially in homes. This study aimed to investigate the most important particle-bound PAH sources and exposure determinants in PM 2.5 samples collected in 19 homes located in northern Italy. Complementary information about ion content in PM 10 was also collected in 12 of these homes. Three methods were used for the identification of PAH sources and determinants: diagnostic ratios with principal component and hierarchical cluster analyses (PCA and HCA), chemical mass balance (CMB) and linear mixed models (LMMs). This combined and tiered approach allowed the infiltration of outdoor PAHs into indoor environments to be identified as the most important source in winter, with a relevant role played by biomass burning and traffic exhausts to be identified as a general source of PAHs in both seasons. Tobacco smoke exhibited an important impact on PAH levels in smokers' homes, whereas in the whole sample, cooking food and natural gas sources played a minor or negligible role. Nitrate, sulfate and ammonium were the main inorganic constituents of indoor PM 10 owing to the secondary formation of ammonium sulfates and nitrates. Copyright © 2016 Elsevier Ltd. All rights reserved.

  3. Preconcentration of lead using solidification of floating organic drop and its determination by electrothermal atomic absorption spectrometry

    Directory of Open Access Journals (Sweden)

    Mahmoud Chamsaz

    2013-07-01

    Full Text Available A simple microextraction method based on solidification of a floating organic drop (SFOD was developed for preconcentration of lead prior to its determination by electrothermal atomic absorption spectrometry (ETAAS. Ammonium pyrolidinedithiocarbamate (APDC was used as complexing agent, and the formed complex was extracted into a 20 μL of 1-undecanol. The extracted complex was diluted with ethanol and injected into a graphite furnace. An orthogonal array design (OAD with OA16 (45 matrix was employed to study the effects of different parameters such as pH, APDC concentration, stirring rate, sample solution temperature and the exposure time on the extraction efficiency. Under the optimized experimental conditions the limit of detection (based on 3 s and the enhancement factor were 0.058 μg L−1 and 113, respectively. The relative standard deviation (RSD for 8 replicate determinations of 1 μg L−1 of Pb was 8.8%. The developed method was validated by the analysis of certified reference materials and was successfully applied to the determination of lead in water and infant formula base powder samples.

  4. Lead determinations in human bone by particle induced x-ray emission (PIXE) and graphite furnace atomic absorption spectrometry (GFAAS)

    Energy Technology Data Exchange (ETDEWEB)

    Deibel, M A; Savage, J M; Robertson, J D; Ehmann, W D [Kentucky Univ., Lexington, KY (United States). Dept. of Chemistry; Markesbery, W R [Kentucky Univ., Lexington, KY (United States)

    1995-08-01

    Chronic lead (Pb) intoxication has been linked to Alzheimer`s disease (AD). Lead, like many heavy elements, tends to accumulate in bone. Pixe is a powerful analytical tool which permits the determination of Pb at the {mu}g/g level without requiring sample digestion. GFAAS is one of the most sensitive methods for the determination of Pb and is capable of determining ng/g levels is solution. For bone analyses by GFAAS, sample dissolution and a matrix modifier are required. Rib bone samples were analyzed for Pb by PIXE and GFAAS. IAEA Animal Bone (H-5) was used as a secondary standard for Pb with both methods to ensure accuracy. The range of Pb concentrations in human rib bone was 1.4-11.5 {mu}/g for the trabecular surface by PIXE, 1.3-45 {mu}g/g for the cortical surface by PIXE, and 1.54-11.75 {mu}g/g for whole bone by GFAAS. No significant difference p.<0.05 was found for AD versus control for either surface or for whole bone. (author). 17 refs., 2 figs., 3 tabs.

  5. Lead determinations in human bone by particle induced x-ray emission (PIXE) and graphite furnace atomic absorption spectrometry (GFAAS)

    International Nuclear Information System (INIS)

    Deibel, M.A.; Savage, J.M.; Robertson, J.D.; Ehmann, W.D.

    1995-01-01

    Chronic lead (Pb) intoxication has been linked to Alzheimer's disease (AD). Lead, like many heavy elements, tends to accumulate in bone. Pixe is a powerful analytical tool which permits the determination of Pb at the μg/g level without requiring sample digestion. GFAAS is one of the most sensitive methods for the determination of Pb and is capable of determining ng/g levels is solution. For bone analyses by GFAAS, sample dissolution and a matrix modifier are required. Rib bone samples were analyzed for Pb by PIXE and GFAAS. IAEA Animal Bone (H-5) was used as a secondary standard for Pb with both methods to ensure accuracy. The range of Pb concentrations in human rib bone was 1.4-11.5 μ/g for the trabecular surface by PIXE, 1.3-45 μg/g for the cortical surface by PIXE, and 1.54-11.75 μg/g for whole bone by GFAAS. No significant difference (p.<0.05 was found for AD versus control for either surface or for whole bone. (author). 17 refs., 2 figs., 3 tabs

  6. Electrochemical stripping determination of traces of copper, lead, cadmium and zinc in zirconium metal and zirconium dioxide

    International Nuclear Information System (INIS)

    Stulik, K.; Beran, P.; Dolezal, J.; Opekar, F.

    1978-01-01

    Procedures have been developed for the determination of copper, lead, cadmium and zinc in zirconium metal and zirconium dioxide, at concentrations of 1ppm or less. Zirconium metal was dissolved in sulphuric acid, and zirconium dioxide decomposed under pressure with hydrofluoric acid. Sample solutions were prepared in dilute sulphuric acid. For the stripping determination, the sample solution was either mixed with a complexing tartrate base electrolyte or the pre-electrolysis was carried out in acid solution, with the acid solution being exchanged for a pure base electrolyte (e.g. an acetate buffer) for the stripping step. The stripping step was monitored by d.c., differential pulse and Kalousek commutator voltammetry and the three methods were compared. A stationary mercury-drop electrode can generally be used for all the methods, whereas a mercury-film electrode is suitable only for the d.c. voltammetric determination of copper, lead and cadmium, as pulse measurements with films are poorly reproducible and the electrodes are easily damaged. The relative standard deviation does not exceed 20%. Some samples contained relatively large amounts of copper, which is best separated by electrodeposition on a platinum electrode. (author)

  7. Preparation and determination of kerma for Iridium 192 sources of low dose rate for brachytherapy

    International Nuclear Information System (INIS)

    Tendilla, J.I.; Tovar M, V.; Mitsoura, E.; Aguilar H, F.; Alanis M, J.

    2000-01-01

    The practice of Brachytherapy with Iridium-192 sources of low dose rate (0.4 - 0.8 Gy/h) is a technique used in the treatment of diverse illnesses. in this work the preparation, quality control and calibration are presented in terms of kerma in air of Iridium-192 using as target these recycled Iridium-Platinum wires. The targets were obtained as decayed sources of different radio therapeutical centers in the country and they were characterized by Scanning electron microscopy in order to determine their chemical composition. Subsequently it was developed an experimental design to establish the effect of neutron flux, geometrical array and irradiation time over the activity and percentage of the sources homogeneity. The homogeneity was determined by auto radiography and by Gamma spectroscopy. Once the optimal irradiation conditions were established, it is determined the apparent activity and kerma in air using a well type ionization chamber with traceability to a primary laboratory. Iridium-192 sources were obtained with an average homogeneity 96 %, apparent activity 282.129 ± 0.531 M Bq and kerma in air 0.03200 ± 0.00006 m Gy m/h A. (Author)

  8. Determination of the maximum-depth to potential field sources by a maximum structural index method

    Science.gov (United States)

    Fedi, M.; Florio, G.

    2013-01-01

    A simple and fast determination of the limiting depth to the sources may represent a significant help to the data interpretation. To this end we explore the possibility of determining those source parameters shared by all the classes of models fitting the data. One approach is to determine the maximum depth-to-source compatible with the measured data, by using for example the well-known Bott-Smith rules. These rules involve only the knowledge of the field and its horizontal gradient maxima, and are independent from the density contrast. Thanks to the direct relationship between structural index and depth to sources we work out a simple and fast strategy to obtain the maximum depth by using the semi-automated methods, such as Euler deconvolution or depth-from-extreme-points method (DEXP). The proposed method consists in estimating the maximum depth as the one obtained for the highest allowable value of the structural index (Nmax). Nmax may be easily determined, since it depends only on the dimensionality of the problem (2D/3D) and on the nature of the analyzed field (e.g., gravity field or magnetic field). We tested our approach on synthetic models against the results obtained by the classical Bott-Smith formulas and the results are in fact very similar, confirming the validity of this method. However, while Bott-Smith formulas are restricted to the gravity field only, our method is applicable also to the magnetic field and to any derivative of the gravity and magnetic field. Our method yields a useful criterion to assess the source model based on the (∂f/∂x)max/fmax ratio. The usefulness of the method in real cases is demonstrated for a salt wall in the Mississippi basin, where the estimation of the maximum depth agrees with the seismic information.

  9. Determination of Original Infection Source of H7N9 Avian Influenza by Dynamical Model

    Science.gov (United States)

    Zhang, Juan; Jin, Zhen; Sun, Gui-Quan; Sun, Xiang-Dong; Wang, You-Ming; Huang, Baoxu

    2014-05-01

    H7N9, a newly emerging virus in China, travels among poultry and human. Although H7N9 has not aroused massive outbreaks, recurrence in the second half of 2013 makes it essential to control the spread. It is believed that the most effective control measure is to locate the original infection source and cut off the source of infection from human. However, the original infection source and the internal transmission mechanism of the new virus are not totally clear. In order to determine the original infection source of H7N9, we establish a dynamical model with migratory bird, resident bird, domestic poultry and human population, and view migratory bird, resident bird, domestic poultry as original infection source respectively to fit the true dynamics during the 2013 pandemic. By comparing the date fitting results and corresponding Akaike Information Criterion (AIC) values, we conclude that migrant birds are most likely the original infection source. In addition, we obtain the basic reproduction number in poultry and carry out sensitivity analysis of some parameters.

  10. Determining the temperature and density distribution from a Z-pinch radiation source

    International Nuclear Information System (INIS)

    Matuska, W.; Lee, H.

    1997-01-01

    High temperature radiation sources exceeding one hundred eV can be produced via z-pinches using currently available pulsed power. The usual approach to compare the z-pinch simulation and experimental data is to convert the radiation output at the source, whose temperature and density distributions are computed from the 2-D MHD code, into simulated data such as a spectrometer reading. This conversion process involves a radiation transfer calculation through the axially symmetric source, assuming local thermodynamic equilibrium (LTE), and folding the radiation that reaches the detector with the frequency-dependent response function. In this paper the authors propose a different approach by which they can determine the temperature and density distributions of the radiation source directly from the spatially resolved spectral data. This unfolding process is reliable and unambiguous for the ideal case where LTE holds and the source is axially symmetric. In reality, imperfect LTE and axial symmetry will introduce inaccuracies into the unfolded distributions. The authors use a parameter optimization routine to find the temperature and density distributions that best fit the data. They know from their past experience that the radiation source resulting from the implosion of a thin foil does not exhibit good axial symmetry. However, recent experiments carried out at Sandia National Laboratory using multiple wire arrays were very promising to achieve reasonably good symmetry. For these experiments the method will provide a valuable diagnostic tool

  11. Determination of arsenic, antimony, bismuth, cadmium, copper, lead, molybdenum, silver and zinc in geological materials by atomic-absorption spectrometry

    Science.gov (United States)

    Viets, J.G.; O'Leary, R. M.; Clark, Robert J.

    1984-01-01

    Arsenic, antimony, bismuth, cadmium, copper, lead, molybdenum, silver and zinc are very useful elements in geochemical exploration. In the proposed method, geological samples are fused with potassium pyrosulphate and the fusate is dissolved in a solution of hydrochloric acid, ascorbic acid and potassium iodide. When this solution is shaken with a 10% V/V Aliquat 336 - isobutyl methyl ketone organic phase, the nine elements of interest are selectively partitioned in the organic phase. All nine elements can then be determined in the organic phase using flame atomic-absorption spectrometry. The method is rapid and allows the determination of Ag and Cd at levels down to 0.1 p.p.m., Cu, Mo, and Zn down to 0.5 p.p.m., Pb, Bi and Sb down to 1 p.p.m. and As down to 5 p.p.m. in geological materials.

  12. Determination of toxic elements (mercury, cadmium, lead, tin and arsenic) in fish and shellfish samples. Risk assessment for the consumers.

    Science.gov (United States)

    Olmedo, P; Pla, A; Hernández, A F; Barbier, F; Ayouni, L; Gil, F

    2013-09-01

    Although fish intake has potential health benefits, the presence of metal contamination in seafood has raised public health concerns. In this study, levels of mercury, cadmium, lead, tin and arsenic have been determined in fresh, canned and frozen fish and shellfish products and compared with the maximum levels currently in force. In a further step, potential human health risks for the consumers were assessed. A total of 485 samples of the 43 most frequently consumed fish and shellfish species in Andalusia (Southern Spain) were analyzed for their toxic elements content. High mercury concentrations were found in some predatory species (blue shark, cat shark, swordfish and tuna), although they were below the regulatory maximum levels. In the case of cadmium, bivalve mollusks such as canned clams and mussels presented higher concentrations than fish, but almost none of the samples analyzed exceeded the maximum levels. Lead concentrations were almost negligible with the exception of frozen common sole, which showed median levels above the legal limit. Tin levels in canned products were far below the maximum regulatory limit, indicating that no significant tin was transferred from the can. Arsenic concentrations were higher in crustaceans such as fresh and frozen shrimps. The risk assessment performed indicated that fish and shellfish products were safe for the average consumer, although a potential risk cannot be dismissed for regular or excessive consumers of particular fish species, such as tuna, swordfish, blue shark and cat shark (for mercury) and common sole (for lead). Copyright © 2013 Elsevier Ltd. All rights reserved.

  13. Determination of the direction to a source of antineutrinos via inverse beta decay in Double Chooz

    Science.gov (United States)

    Nikitenko, Ya.

    2016-11-01

    To determine the direction to a source of neutrinos (and antineutrinos) is an important problem for the physics of supernovae and of the Earth. The direction to a source of antineutrinos can be estimated through the reaction of inverse beta decay. We show that the reactor neutrino experiment Double Chooz has unique capabilities to study antineutrino signal from point-like sources. Contemporary experimental data on antineutrino directionality is given. A rigorous mathematical approach for neutrino direction studies has been developed. Exact expressions for the precision of the simple mean estimator of neutrinos' direction for normal and exponential distributions for a finite sample and for the limiting case of many events have been obtained.

  14. Determination of the X, Y coordinates of a pulsed ultrasonic source of signals

    International Nuclear Information System (INIS)

    Sokolov, B.V.; Shemyakin, V.V.

    1975-01-01

    A range of problems in predicting the emergency state of large-scale vessel housings are determined for subsequent solution involving acoustic emission phenomena. The authors specify the position of a given problem and present substantial grounds for selecting the minimum number of group signal receivers for unambiguous calculation of the location of the source. Relationships are obtained between X, Y - the coordinates of the pulse signal source - and experimentally measured time differences in recording of signals by group receivers. A criterion is given for selecting the true signal group combination when the receivers simultaneously record waves from several sources. Specific suggestions are made regarding the experimental information to be stored in a central computer for subsequent processing [ru

  15. A rugged and transferable method for determining blood cadmium, mercury, and lead with inductively coupled plasma-mass spectrometry

    International Nuclear Information System (INIS)

    McShane, William J.; Pappas, R. Steven; Wilson-McElprang, Veronica; Paschal, Dan

    2008-01-01

    A simple, high-throughput method for determining total cadmium, mercury, and lead in blood in cases of suspected exposure, using inductively coupled plasma-mass spectrometry (ICP-MS), has been developed and validated. One part matrix-matched standards, blanks, or aliquots of blood specimens were diluted with 49 parts of a solution containing 0.25% (w/w) tetramethylammonium hydroxide; 0.05% v/v Triton X-100 (blood cell membranes and protein solubilization); 0.01% (w/v) ammonium pyrolidinedithiocarbamate (mercury memory effect prevention and oxidation state stabilization, solubilization by complexation of all three metals); 1% v/v isopropanol (signal enhancement); and 10 μg/L iridium (internal standard). Thus the final dilution factor is 1 + 49. The method provides the basis for the determination of total cadmium, mercury, and lead for assessment of environmental, occupational, accidental ingestion or elevated exposures from other means. Approximately 80 specimens, including blanks, calibration standards, and quality control materials can be processed in an 8-h day. The method has been evaluated by examining reference materials from the National Institute of Standards and Technology, as well as by participation in six rounds of proficiency testing intercomparisons led by the Wadsworth Center of the New York State Department of Health. This method was developed for the purpose of increasing U.S. emergency response laboratory capacity. To this end, 33 U.S. state, and 1 district health department laboratories have validated this method in their own laboratories

  16. A rugged and transferable method for determining blood cadmium, mercury, and lead with inductively coupled plasma-mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    McShane, William J. [Battelle-Centers for Disease Control and Prevention, Division of Laboratory Sciences, Emergency Response and Air Toxicants Branch, 4770 Buford Highway, MS F-44, Atlanta, GA 30341 (United States)], E-mail: WMcShane@cdc.gov; Pappas, R. Steven [Centers for Disease Control and Prevention, Division of Laboratory Sciences, Emergency Response and Air Toxicants, 4770 Buford Highway, MS F-44, Atlanta, GA 30341 (United States)], E-mail: RPappas@cdc.gov; Wilson-McElprang, Veronica [Battelle-Centers for Disease Control and Prevention, Division of Laboratory Sciences, Emergency Response and Air Toxicants Branch, 4770 Buford Highway, MS F-44, Atlanta, GA 30341 (United States)], E-mail: VWilsonMcelprang@cdc.gov; Paschal, Dan [Centers for Disease Control and Prevention, Division of Laboratory Sciences, Emergency Response and Air Toxicants, 4770 Buford Highway, MS F-44, Atlanta, GA 30341 (United States)], E-mail: DPaschal@cdc.gov

    2008-06-15

    A simple, high-throughput method for determining total cadmium, mercury, and lead in blood in cases of suspected exposure, using inductively coupled plasma-mass spectrometry (ICP-MS), has been developed and validated. One part matrix-matched standards, blanks, or aliquots of blood specimens were diluted with 49 parts of a solution containing 0.25% (w/w) tetramethylammonium hydroxide; 0.05% v/v Triton X-100 (blood cell membranes and protein solubilization); 0.01% (w/v) ammonium pyrolidinedithiocarbamate (mercury memory effect prevention and oxidation state stabilization, solubilization by complexation of all three metals); 1% v/v isopropanol (signal enhancement); and 10 {mu}g/L iridium (internal standard). Thus the final dilution factor is 1 + 49. The method provides the basis for the determination of total cadmium, mercury, and lead for assessment of environmental, occupational, accidental ingestion or elevated exposures from other means. Approximately 80 specimens, including blanks, calibration standards, and quality control materials can be processed in an 8-h day. The method has been evaluated by examining reference materials from the National Institute of Standards and Technology, as well as by participation in six rounds of proficiency testing intercomparisons led by the Wadsworth Center of the New York State Department of Health. This method was developed for the purpose of increasing U.S. emergency response laboratory capacity. To this end, 33 U.S. state, and 1 district health department laboratories have validated this method in their own laboratories.

  17. Depth determination of buried caesium-137 and cobalt-60 sources using scatter peak data

    International Nuclear Information System (INIS)

    Adams, J. C.; Joyce, M. J.; Mellor, M.

    2009-01-01

    An investigation into an alternative approach to 3D (3-dimensional) source mapping is proposed, by combining the insights of two existing techniques. The first of these is a 3D 'imaging' tool, N-Visage TM that has been developed by REACT Engineering Ltd. This technique is efficient and robust, but is not a true 3D technique as it relies on user-supplied 2D (2-dimensional) manifolds to constrain source locations. The second technique uses the γ-photopeak and an X-ray peak to determine radionuclide source depth using a relative attenuation method. We look at the possibility of combining both techniques to constrain both the location and depth of a radiological source buried under shielding. It is believed a combined method using spectra recorded above the shielding object will be of use in the nuclear decommissioning and land contamination industries. N-Visage TM has previously been used to map source distributions of mixed radionuclides with complex geometries through shielding media. The software works by producing a computer model which recreates the experimental setup. A survey is imported, comprising a set of γ-spectra recorded with an instrument of known efficiency and isotropy taken at a variety of locations around the area of interest. A survey plan recording the location and orientation of the instrument for each reading is also reconstructed. N-Visage TM is then able to determine the locations of the source(s) without prior knowledge of exactly where they are located, by building and inverting a simple physical model relating potential source locations to the recorded spectra. This research sets out to investigate the possibility of combining the geometric insights of N-Visage TM with a method of extracting depth information from scatter data, rather than the X-ray peak. By combining the γ-photopeak and scatter areas of a spectrum, the thickness of the shielding media between source and detector can potentially be inferred. Using scattered photons rather

  18. Sources of variability in the determination by evaporation method of gross alpha activity in water samples

    Energy Technology Data Exchange (ETDEWEB)

    Baeza, A.; Corbacho, J.A. [LARUEX, Caceres (Spain). Environmental Radioactivity Lab.

    2013-07-01

    Determining the gross alpha activity concentration of water samples is one way to screen for waters whose radionuclide content is so high that its consumption could imply surpassing the Total Indicative Dose as defined in European Directive 98/83/EC. One of the most commonly used methods to prepare the sources to measure gross alpha activity in water samples is desiccation. Its main advantages are the simplicity of the procedure, the low cost of source preparation, and the possibility of simultaneously determining the gross beta activity. The preparation of the source, the construction of the calibration curves, and the measurement procedure itself involve, however, various factors that may introduce sufficient variability into the results to significantly affect the screening process. We here identify the main sources of this variability, and propose specific procedures to follow in the desiccation process that will reduce the uncertainties, and ensure that the result is indeed representative of the sum of the activities of the alpha emitters present in the sample. (orig.)

  19. Determination of regression functions for the charging and discharging processes of valve regulated lead-acid batteries

    Directory of Open Access Journals (Sweden)

    Vukić Vladimir Đ.

    2012-01-01

    Full Text Available Following a deep discharge of AGM SVT 300 valve-regulated lead-acid batteries using the ten-hour discharge current, the batteries were charged using variable current. In accordance with the obtained results, exponential and polynomial functions for the approximation of the specified processes were analyzed. The main evaluation instrument for the quality of the implemented approximations was the adjusted coefficient of determination R-2. It was perceived that the battery discharge process might be successfully approximated with both an exponential and the second order polynomial function. On all the occasions analyzed, values of the adjusted coefficient of determination were greater than 0.995. The charging process of the deeply discharged batteries was successfully approximated with the exponential function; the measured values of the adjusted coefficient of determination being nearly 0.95. Apart from the high measured values of the adjusted coefficient of determination, polynomial approximations of the second and third order did not provide satisfactory results regarding the interpolation of the battery charging characteristics. A possibility for a practical implementation of the procured regression functions in uninterruptible power supply systems was described.

  20. Methods for the determination of lunisolar precession from observations of extragalactic radio sources

    International Nuclear Information System (INIS)

    Elsmore, B.

    1976-01-01

    Although it is not practicable at present to determine the position or motion of the equinox using radio techniques, lunisolar precession may be determined from measurements at two epochs of differences of (i) Right Ascension -RA, and (ii) Declinations - Dec., of extragalactic radio sources. The determinations are largely free from systematic errors, and the magnitudes of random errors, arising principally from tropospheric irregularities, are given for observations with the Cambridge 5-km telescope. Some first epoch measure-ments have been made with this instrument and it is estimated that by carrying out second epoch measurements after an interval of 5 yr, the centennial value of lunisolar precession will be determined with a standard error of +- 0''.25. (author)

  1. Glovebox enclosed dc plasma source for the determination of metals in plutonium

    International Nuclear Information System (INIS)

    Morris, W.F.

    1986-01-01

    The direct current plasma source of a Beckman Spectraspan IIIB emission spectrometer was enclosed in a glovebox at Lawrence Livermore National Laboratory in December 1982. Since that time, the system has been used for the routine determination of alloy and impurity metals in plutonium. This paper presents the systematic steps involved in developing the glovebox and gives information regarding performance of the plasma in the glovebox and the effectiveness of containment of plutonium. 8 refs., 9 figs., 3 tabs

  2. Dosimetry audit on the accuracy of 192Ir brachytherapy source strength determinations in Sweden

    Energy Technology Data Exchange (ETDEWEB)

    Carlsson Tedgren, Aasa

    2007-11-15

    The absorbed dose delivered to the patient in brachytherapy is directly proportional to the source strength in terms of the reference air-kerma rate (RAKR). Verification of this quantity by the hospitals is widely recognized as an important part of a quality assurance program. An external audit was performed on behalf of the Secondary Standard Dosimetry Laboratory at the Swedish Radiation Protection Authority (SSI). The aim was to investigate how accurately the source-strength in 192Ir brachytherapy is determined at Swedish hospitals. The SSI reference well-type ion chamber and calibrated equipment were used to measure the RAKR of an 192Ir source in each of the 14 Swedish afterloading units. Comparisons with values determined by vendors and hospitals were made. Agreement in values of RAKR as determined by SSI, hospitals and vendors were in all cases within the +-3% uncertainty (at a coverage factor of k=2), typically guaranteed by the vendors. The good agreement reflects the robustness and easy handling of well-type chambers designed for brachytherapy in use by all Swedish hospitals. The 192Ir calibration service planned at SSI will solve the hospitals current problem with recalibration of equipment. SSI can also advise hospitals to follow the IAEA recommendations for measurement techniques and maintenance of equipment. It is worthwhile for the hospitals to establish their own ratio (or deviation) with the vendor and follow it as function of time. Such a mean-ratio embeds systematic differences of various origins and have a lower uncertainty than has the RAKR alone, making it useful for early detection of problems with equipment or routines. SSI could also define requirements for the agreement between source strengths as determined by hospitals and vendors and couple this to an action plan, dependent on level of disagreement, and some kind of reporting to SSI

  3. Dosimetry audit on the accuracy of 192Ir brachytherapy source strength determinations in Sweden

    International Nuclear Information System (INIS)

    Carlsson Tedgren, Aasa

    2007-11-01

    The absorbed dose delivered to the patient in brachytherapy is directly proportional to the source strength in terms of the reference air-kerma rate (RAKR). Verification of this quantity by the hospitals is widely recognized as an important part of a quality assurance program. An external audit was performed on behalf of the Secondary Standard Dosimetry Laboratory at the Swedish Radiation Protection Authority (SSI). The aim was to investigate how accurately the source-strength in 192 Ir brachytherapy is determined at Swedish hospitals. The SSI reference well-type ion chamber and calibrated equipment were used to measure the RAKR of an 192 Ir source in each of the 14 Swedish afterloading units. Comparisons with values determined by vendors and hospitals were made. Agreement in values of RAKR as determined by SSI, hospitals and vendors were in all cases within the ±3% uncertainty (at a coverage factor of k=2), typically guaranteed by the vendors. The good agreement reflects the robustness and easy handling of well-type chambers designed for brachytherapy in use by all Swedish hospitals. The 192 Ir calibration service planned at SSI will solve the hospitals current problem with recalibration of equipment. SSI can also advise hospitals to follow the IAEA recommendations for measurement techniques and maintenance of equipment. It is worthwhile for the hospitals to establish their own ratio (or deviation) with the vendor and follow it as function of time. Such a mean-ratio embeds systematic differences of various origins and have a lower uncertainty than has the RAKR alone, making it useful for early detection of problems with equipment or routines. SSI could also define requirements for the agreement between source strengths as determined by hospitals and vendors and couple this to an action plan, dependent on level of disagreement, and some kind of reporting to SSI

  4. Determining Sources of Fecal Contamination in Two Rivers of Northumberland County, Virginia

    OpenAIRE

    Szeles, Cheryl Lynne

    2003-01-01

    DETERMINING SOURCES OF FECAL CONTAMINATION IN TWO RIVERS OF NORTHUMBERLAND COUNTY, VIRGINIA By Cheryl Lynne Szeles Dr. Charles Hagedorn III, Chairman Crop and Soil Environmental Sciences (ABSTRACT) The goal of monitoring the water quality of shellfish beds is to provide protection against transmission of water-borne infectious diseases. The Coan River and the Little Wicomico River contain shellfish beds that are closed to harvest due to contamination with fecal ...

  5. Instrumental neutron activation determination of gold in mineral raw materials using a californium neutron source

    International Nuclear Information System (INIS)

    Shilo, N.A.; Ippolitov, E.G.; Ivanenko, V.V.; Kustov, B.N.; Zheleznov, V.V.; Aristov, G.N.; Kovalenko, V.V.; Kondrat'ev, N.B.

    1983-01-01

    A facility using a californium neutron source and a method for the neutron activation analysis of gold were developed. The sensitivity of the determination is 0.1 g/t. The causes of random and systematic errors have been studied. It is concluded that in prospection and evaluation of gold ore deposists, the traditional test tube analysis for gold may be replaced with the developed method. (author)

  6. Determination of dosimetric characteristics of OptiSeedTM a plastic brachytherapy 103Pd source

    International Nuclear Information System (INIS)

    Wang Zhonglu; Hertel, Nolan E.

    2005-01-01

    A new 103 Pd plastic brachytherapy source, OptiSeed TM Model 1032P, is being introduced by International Brachytherapy sa (IBt). Measurements of the dose distributions about the source were performed using LiF thermoluminescent dosimeters (TLD-100) in Virtual Water TM . MCNP5 calculations were performed to determine the dose distributions in Virtual Water TM and liquid water. The source dose rate constant, radial dose function, anisotropy function and anisotropy factor have been determined following the updated AAPM TG-43 recommendations. The measured dose rate constant in the Virtual Water TM phantom was determined to be 0.727±6.9% cGy h -1 U -1 , and the computed value is 0.716±2.1% cGy h -1 U -1 . The Monte-Carlo simulation yielded a dose rate constant of 0.665±2.1% cGy h -1 U -1 in water. The measured dose rate constant in water is 0.675±7.5% cGy h -1 U -1 . It is determined by multiplying the dose rate constant measured in the Virtual Water TM phantom with the ratio of the value calculated in water to that in Virtual Water TM . The average of the measured and calculated dose rate constant is 0.670±5.5% cGy h -1 U -1 . The radial dose functions of the new source were measured for distances ranging from 1 to 7 cm in a Virtual Water TM phantom. The anisotropy functions in Virtual Water TM phantom were measured for distances of 2, 3, 5, and 7 cm. The Monte-Carlo computed radial dose functions, anisotropy functions, and anisotropy factors in both Virtual Water TM phantom and water are reported

  7. Dosimetry audit on the accuracy of {sup 192}Ir brachytherapy source strength determinations in Sweden

    Energy Technology Data Exchange (ETDEWEB)

    Carlsson Tedgren, Aasa

    2007-11-15

    The absorbed dose delivered to the patient in brachytherapy is directly proportional to the source strength in terms of the reference air-kerma rate (RAKR). Verification of this quantity by the hospitals is widely recognized as an important part of a quality assurance program. An external audit was performed on behalf of the Secondary Standard Dosimetry Laboratory at the Swedish Radiation Protection Authority (SSI). The aim was to investigate how accurately the source-strength in {sup 192}Ir brachytherapy is determined at Swedish hospitals. The SSI reference well-type ion chamber and calibrated equipment were used to measure the RAKR of an {sup 192}Ir source in each of the 14 Swedish afterloading units. Comparisons with values determined by vendors and hospitals were made. Agreement in values of RAKR as determined by SSI, hospitals and vendors were in all cases within the {+-}3% uncertainty (at a coverage factor of k=2), typically guaranteed by the vendors. The good agreement reflects the robustness and easy handling of well-type chambers designed for brachytherapy in use by all Swedish hospitals. The {sup 192}Ir calibration service planned at SSI will solve the hospitals current problem with recalibration of equipment. SSI can also advise hospitals to follow the IAEA recommendations for measurement techniques and maintenance of equipment. It is worthwhile for the hospitals to establish their own ratio (or deviation) with the vendor and follow it as function of time. Such a mean-ratio embeds systematic differences of various origins and have a lower uncertainty than has the RAKR alone, making it useful for early detection of problems with equipment or routines. SSI could also define requirements for the agreement between source strengths as determined by hospitals and vendors and couple this to an action plan, dependent on level of disagreement, and some kind of reporting to SSI.

  8. Determination of optimal geometry for cylindrical sources for gamma radiation measurements; Odredjivanje optimalne geometrije za mjerenje gama zracenja cilindrichnih izvora

    Energy Technology Data Exchange (ETDEWEB)

    Sinjeri, Lj; Kulisic, P [Elektra - Zagreb, Zagreb (Yugoslavia)

    1990-07-01

    Low radioactive sources were used for experimental determination of optimal dimensions for cylindrical source using coaxial Ge(Li) detector. Then, calculational procedure is used to find optimal dimensions of cylindrical source. The results from calculational procedure confirm with experimental results. In such way the verification of calculational procedure is done and it can be used for determination of optimal geometry for low radioactive cylindrical sources. (author)

  9. STATCONT: A statistical continuum level determination method for line-rich sources

    Science.gov (United States)

    Sánchez-Monge, Á.; Schilke, P.; Ginsburg, A.; Cesaroni, R.; Schmiedeke, A.

    2018-01-01

    STATCONT is a python-based tool designed to determine the continuum emission level in spectral data, in particular for sources with a line-rich spectrum. The tool inspects the intensity distribution of a given spectrum and automatically determines the continuum level by using different statistical approaches. The different methods included in STATCONT are tested against synthetic data. We conclude that the sigma-clipping algorithm provides the most accurate continuum level determination, together with information on the uncertainty in its determination. This uncertainty can be used to correct the final continuum emission level, resulting in the here called `corrected sigma-clipping method' or c-SCM. The c-SCM has been tested against more than 750 different synthetic spectra reproducing typical conditions found towards astronomical sources. The continuum level is determined with a discrepancy of less than 1% in 50% of the cases, and less than 5% in 90% of the cases, provided at least 10% of the channels are line free. The main products of STATCONT are the continuum emission level, together with a conservative value of its uncertainty, and datacubes containing only spectral line emission, i.e., continuum-subtracted datacubes. STATCONT also includes the option to estimate the spectral index, when different files covering different frequency ranges are provided.

  10. Direct Position Determination of Multiple Non-Circular Sources with a Moving Coprime Array

    Directory of Open Access Journals (Sweden)

    Yankui Zhang

    2018-05-01

    Full Text Available Direct position determination (DPD is currently a hot topic in wireless localization research as it is more accurate than traditional two-step positioning. However, current DPD algorithms are all based on uniform arrays, which have an insufficient degree of freedom and limited estimation accuracy. To improve the DPD accuracy, this paper introduces a coprime array to the position model of multiple non-circular sources with a moving array. To maximize the advantages of this coprime array, we reconstruct the covariance matrix by vectorization, apply a spatial smoothing technique, and converge the subspace data from each measuring position to establish the cost function. Finally, we obtain the position coordinates of the multiple non-circular sources. The complexity of the proposed method is computed and compared with that of other methods, and the Cramer–Rao lower bound of DPD for multiple sources with a moving coprime array, is derived. Theoretical analysis and simulation results show that the proposed algorithm is not only applicable to circular sources, but can also improve the positioning accuracy of non-circular sources. Compared with existing two-step positioning algorithms and DPD algorithms based on uniform linear arrays, the proposed technique offers a significant improvement in positioning accuracy with a slight increase in complexity.

  11. Direct Position Determination of Multiple Non-Circular Sources with a Moving Coprime Array.

    Science.gov (United States)

    Zhang, Yankui; Ba, Bin; Wang, Daming; Geng, Wei; Xu, Haiyun

    2018-05-08

    Direct position determination (DPD) is currently a hot topic in wireless localization research as it is more accurate than traditional two-step positioning. However, current DPD algorithms are all based on uniform arrays, which have an insufficient degree of freedom and limited estimation accuracy. To improve the DPD accuracy, this paper introduces a coprime array to the position model of multiple non-circular sources with a moving array. To maximize the advantages of this coprime array, we reconstruct the covariance matrix by vectorization, apply a spatial smoothing technique, and converge the subspace data from each measuring position to establish the cost function. Finally, we obtain the position coordinates of the multiple non-circular sources. The complexity of the proposed method is computed and compared with that of other methods, and the Cramer⁻Rao lower bound of DPD for multiple sources with a moving coprime array, is derived. Theoretical analysis and simulation results show that the proposed algorithm is not only applicable to circular sources, but can also improve the positioning accuracy of non-circular sources. Compared with existing two-step positioning algorithms and DPD algorithms based on uniform linear arrays, the proposed technique offers a significant improvement in positioning accuracy with a slight increase in complexity.

  12. Event Coverage Detection and Event Source Determination in Underwater Wireless Sensor Networks

    Directory of Open Access Journals (Sweden)

    Zhangbing Zhou

    2015-12-01

    Full Text Available With the advent of the Internet of Underwater Things, smart things are deployed in the ocean space and establish underwater wireless sensor networks for the monitoring of vast and dynamic underwater environments. When events are found to have possibly occurred, accurate event coverage should be detected, and potential event sources should be determined for the enactment of prompt and proper responses. To address this challenge, a technique that detects event coverage and determines event sources is developed in this article. Specifically, the occurrence of possible events corresponds to a set of neighboring sensor nodes whose sensory data may deviate from a normal sensing range in a collective fashion. An appropriate sensor node is selected as the relay node for gathering and routing sensory data to sink node(s. When sensory data are collected at sink node(s, the event coverage is detected and represented as a weighted graph, where the vertices in this graph correspond to sensor nodes and the weight specified upon the edges reflects the extent of sensory data deviating from a normal sensing range. Event sources are determined, which correspond to the barycenters in this graph. The results of the experiments show that our technique is more energy efficient, especially when the network topology is relatively steady.

  13. Coacervative extraction of trace lead from natural waters prior to its determination by electrothermal atomic absorption spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Hagarová, Ingrid, E-mail: hagarova@fns.uniba.sk; Bujdoš, Marek; Matúš, Peter; Kubová, Jana

    2013-10-01

    In this work, a relatively simple and sensitive method for separation/preconcentration of trace lead from natural waters prior to its determination by electrothermal atomic absorption spectrometry has been proposed. The method is based on the extraction of Pb–dithizone chelate with coacervates made up of lauric acid in the presence of potassium ions and methanol. Several important factors affecting extraction efficiency such as pH, concentration of lauric acid and dithizone, ionic strength, incubation and centrifugation time were investigated and optimized. After separation of aqueous bulk solution from surfactant-rich phase, the final extract was redissolved by using 500 μl of methanol acidified with 0.2 mol l{sup −1} HNO{sub 3}. Under the optimized conditions (using initial sample volume of 10 ml), enrichment factor of 17.0, detection limit of 0.12 μg l{sup −1}, quantification limit of 0.38 μg l{sup −1}, relative standard deviation of 4.2% (for 2 μg l{sup −1} of Pb; n = 26), linearity of the calibration graph in the range of 0.5–4.0 μg l{sup −1} (with correlation coefficient better than 0.995) were achieved. The method was validated by the analysis of certified reference material (TMDA-61). Extraction recoveries for the CRM, spiked model solutions and spiked natural water samples were in the range of 91–96%. Finally, the method was applied to the separation/preconcentration and determination of trace lead in natural waters. - Highlights: • The potential of coacervates for the extraction of metal ions is examined. • No difficulties in coupling of ETAAS with the proposed CAE are observed. • Achieved preconcentration factor results in enhanced sensitivity. • Analytical performance is confirmed by the reliable determination of trace Pb. • The proposed CAE is ecofriendly and efficient.

  14. Determination of combustible volatile matter in coal mine roadway dusts by backscatter of x-rays from a radioisotope source

    International Nuclear Information System (INIS)

    Ailwood, C.R.; Bunch, K.; Fookes, R.A.; Gravitis, V.L.; Watt, J.S.

    1977-01-01

    The combustible volatile matter in coal mine roadway dusts (CVM) has been determined using x-ray backscatter techniques. The correlation between x-ray and chemical techniques is reasonably good for the 92 samples from collieries on the Bulli seam, and the maximum error expected at the maximum level of 11.5 weight per cent CVM permitted in the N.S.W. Coal Mines Regulation Act, 1912, as amended, is about +- 2.5 weight per cent. This x-ray technique can be used only when the combustible volatile content of the coal matter (CVM) varies within a limited range, and a separate calibration is required for each coal seam. Portable equipment based on a radioisotope x-ray source and digital ratemeter makes possible simple and rapid analysis, and with adaptation to use in coal mines should lead to much more comprehensive testing of roadways and hence improved overall prevention of coal dust explosions. (author)

  15. Theoretical and experimental determination of dosimetric characteristics for ADVANTAGETM Pd-103 brachytherapy source

    International Nuclear Information System (INIS)

    Meigooni, Ali S.; Dini, Sharifeh A.; Awan, Shahid B.; Dou, Kai; Koona, Rafiq A.

    2006-01-01

    ADVANTAGE TM Pd-103 brachytherapy source has been recently introduced by IsoAid TM for prostate permanent implants. Dosimetric characteristics (Dose rate constant, radial dose function, 2D-, and 1D-anisotropy functions) of this source model have been determined using both theoretical and experimental methods, following the updated TG-43U1 protocol. Derivation of the dose rate constant was based on recent NIST WAFAC calibration performed in accordance with the 1999 Standards. Measurements were performed in Solid Water TM using LiF TLD chips and the theoretical calculations were performed in Solid Water TM and liquid water phantom materials using PTRAN Monte Carlo code. The results of the Monte Carlo simulation have shown a dose rate constant of 0.69 cGy h -1 U -1 in liquid water and 0.67 cGy h -1 U -1 in Solid Water TM medium. The measured dose rate constant in Solid Water TM was found to be 0.68±8% cGy h -1 U -1 , which is in a good agreement (within ±5%) to the Monte Carlo simulated data. The 2D- and 1D-anisotropy functions of the ADVANTAGE TM Pd-103 source were calculated for radial distances ranging from 0.5 to 5.0 cm. Radial dose function was determined for radial distances ranging from 0.2 to 8.0 cm using line source approximation. All these calculations are based on L eff equal to 3.61 cm, calculated following TG-43U1 recommendations. The tabulated data for 2D-anisotropy function, 1D-anisotropy function, dose rate constant and radial dose function have been produced for clinical application of this source model

  16. Theoretical and experimental determination of dosimetric characteristics for ADVANTAGE{sup TM} Pd-103 brachytherapy source

    Energy Technology Data Exchange (ETDEWEB)

    Meigooni, Ali S. [Department of Radiation Medicine, University of Kentucky Medical Center, 800 Rose Street, Lexington, Kentucky 40536 (United States)]. E-mail: alimeig@uky.edu; Dini, Sharifeh A. [Department of Radiation Medicine, University of Kentucky Medical Center, 800 Rose Street, Lexington, Kentucky 40536 (United States); Awan, Shahid B. [Department of Radiation Medicine, University of Kentucky Medical Center, 800 Rose Street, Lexington, Kentucky 40536 (United States); Dou, Kai [Department of Radiation Medicine, University of Kentucky Medical Center, 800 Rose Street, Lexington, Kentucky 40536 (United States); Koona, Rafiq A. [Department of Radiation Medicine, University of Kentucky Medical Center, 800 Rose Street, Lexington, Kentucky 40536 (United States)

    2006-08-15

    ADVANTAGE{sup TM} Pd-103 brachytherapy source has been recently introduced by IsoAid{sup TM} for prostate permanent implants. Dosimetric characteristics (Dose rate constant, radial dose function, 2D-, and 1D-anisotropy functions) of this source model have been determined using both theoretical and experimental methods, following the updated TG-43U1 protocol. Derivation of the dose rate constant was based on recent NIST WAFAC calibration performed in accordance with the 1999 Standards. Measurements were performed in Solid Water{sup TM} using LiF TLD chips and the theoretical calculations were performed in Solid Water{sup TM} and liquid water phantom materials using PTRAN Monte Carlo code. The results of the Monte Carlo simulation have shown a dose rate constant of 0.69 cGy h{sup -1} U{sup -1} in liquid water and 0.67 cGy h{sup -1} U{sup -1} in Solid Water{sup TM} medium. The measured dose rate constant in Solid Water{sup TM} was found to be 0.68{+-}8% cGy h{sup -1} U{sup -1}, which is in a good agreement (within {+-}5%) to the Monte Carlo simulated data. The 2D- and 1D-anisotropy functions of the ADVANTAGE{sup TM} Pd-103 source were calculated for radial distances ranging from 0.5 to 5.0 cm. Radial dose function was determined for radial distances ranging from 0.2 to 8.0 cm using line source approximation. All these calculations are based on L {sub eff} equal to 3.61 cm, calculated following TG-43U1 recommendations. The tabulated data for 2D-anisotropy function, 1D-anisotropy function, dose rate constant and radial dose function have been produced for clinical application of this source model.

  17. NEAR REAL-TIME DETERMINATION OF EARTHQUAKE SOURCE PARAMETERS FOR TSUNAMI EARLY WARNING FROM GEODETIC OBSERVATIONS

    Directory of Open Access Journals (Sweden)

    S. Manneela

    2016-06-01

    Full Text Available Exemplifying the tsunami source immediately after an earthquake is the most critical component of tsunami early warning, as not every earthquake generates a tsunami. After a major under sea earthquake, it is very important to determine whether or not it has actually triggered the deadly wave. The near real-time observations from near field networks such as strong motion and Global Positioning System (GPS allows rapid determination of fault geometry. Here we present a complete processing chain of Indian Tsunami Early Warning System (ITEWS, starting from acquisition of geodetic raw data, processing, inversion and simulating the situation as it would be at warning center during any major earthquake. We determine the earthquake moment magnitude and generate the centroid moment tensor solution using a novel approach which are the key elements for tsunami early warning. Though the well established seismic monitoring network, numerical modeling and dissemination system are currently capable to provide tsunami warnings to most of the countries in and around the Indian Ocean, the study highlights the critical role of geodetic observations in determination of tsunami source for high-quality forecasting.

  18. Vaporization of mercury from molten lead droplets doped with mercury: Pb/Hg source term experiment for the APT/SILC target

    International Nuclear Information System (INIS)

    Tutu, N.K.; Greene, G.A.

    1994-09-01

    Experiments were performed to measure the fraction of mercury inventory released when droplets of molten lead, doped with a known concentration of mercury, fall through a controlled environment. The temperature of molten droplets ranged from 335 C to 346 C, and the concentration of mercury in the droplets ranged from 0.2 mass % to 1.0 mass %. The environment consisted of an air stream, at a temperature nominally equal to the melt temperature, and moving vertically upwards at a velocity of 10 cm/s. Direct observations and chemical analysis showed that no mercury was released from the molten droplets. Based upon the experimental results, it is concluded that no mercury vapor is likely to be released from the potentially molten source rod material in the APT-SILC Neutron Source Array to the confinement atmosphere during a postulated Large Break Loss Of Coolant Accident scenario leading to the melting of a fraction of the source rods

  19. Determination of trace element concentrations and stable lead, uranium and thorium isotope ratios by quadrupole-ICP-MS in NORM and NORM-polluted sample leachates

    International Nuclear Information System (INIS)

    Mas, J.L.; Villa, M.; Hurtado, S.; García-Tenorio, R.

    2012-01-01

    Highlights: ► Polluted sediment and NORM samples. ► An efficient yet fast process allowing multi-parametric determinations in 206 Pb/ 207 Pb/ 208 Pb, 238 U/ 234 U and 232 Th/ 230 Th isotope ratios using a single sample aliquot and a single instrument (ICP-QMS). Eichrom UTEVA ® extraction chromatography minicolumns were used to separate uranium and thorium in sample leachates. Independent ICP-MS determinations of uranium and thorium isotope ratios were carried out afterwards. Previously a small aliquot of the leachate was used for the determination of trace element concentrations and lead isotope ratios. Several radiochemical arrangements were tested to get maximum performances and simplicity of the method. The performances of the method were studied in terms of chemical yields of uranium and thorium and removal of the potentially interfering elements. The established method was applied to samples from a chemical industry and sediments collected in a NORM-polluted scenario. The results obtained from our method allowed us to infer not only the extent, but also the sources of the contamination in the area.

  20. The determination of cadmium, lead and vanadium by high resolution ICP-MS in Antarctic snow samples

    Energy Technology Data Exchange (ETDEWEB)

    Lanza, F. [Joh. Gutenberg Univ., Mainz (Germany). Inst. fuer Anorganische und Analytische Chemie; Trincherini, P. [European Union Joint Research Centre, Ispra, VA (Italy). Inst. of Environment

    2000-02-01

    Double focusing ICP-MS was successfully used in this research for the direct determination of the cadmium, lead and vanadium content of a set of Antarctic samples collected during the 11. Italian Expedition to Antarctica. For cadmium and lead measurements the low resolution mode was chosen since it ensured the highest ion sensitivity and it allowed the highest detection limits to be attained; in the case of vanadium the high resolution mode was used to solve the isobaric interference. As far as vanadium and cadmium are concerned by GFAAS coupled with different preconcentration procedures. The vanadium, cadmium and lead content measured in a riverine water reference material (SRLS-3) was found in agreement with the certified values. [Italian] Si e' utilizzato uno spettrometro ICP-MS a doppia focalizzazione per la determinazione diretta di cadmio, piombo e vanadio in una serie di campioni di neve antartica superficiale raccolta durante l'undicesima spedizione italiana in Antartide. Per le determinazioni di cadmio e piombo si e' scelta la procedura a bassa risoluzione, che ha garantito la piu' elevata sensibilita' ed ha permesso di ottenere limiti di determinazione migliori; nel caso del vanadio si e' utilizzata la procedura ad alta risoluzione che ha permesso di risolvere problemi di interferenza isobarica. Per quanto riguarda cadmio e vanadio, i risultati delle determinazioni mediante ICP-MS sono risultati in buon accordo con quelli ottenuti mediante GFAAS accoppiata a diverse procedure di preconcentrazione. Il contenuto di cadmio, piombo e vanadio misurato con le procedure sviluppate in un campione certificato di acqua di fiume (SRLS-3) e' risultato in accordo con i valori certificati.

  1. Hydrogen isotopic spectral determination in inert gases with the use of light source with contracted discharge

    International Nuclear Information System (INIS)

    Nemets, V.M.; Solov'ev, A.A.

    1981-01-01

    Isotopic-spectral technique for hydrogen determination in helium, neon and argon is developed. It employs a contracted high-frequency discharge as a light source to decrease the distorting effect. of a dummy signal and the ''memory'' effect of the discharge tube. The discharge is realized in a quartz tube approximately 7 mm dia. and gas pressure in it approximately 6x10 4 Pa. The analysis technique comprises sampling of gas, dosed introduction of deuterium into the sample, selection of a mixture portion into the discharge tube, spectroscopic determination of hydrogen isotope ratio and calculation of the sought for hydrogen concentration. The lower boundary of the determined concentrations of hydrogen constitutes 7x10 - 5 , 2x10 - 4 and 4x10 - 4 volumetric per cent in helium, neon, and argon, respectively

  2. Determination of lead element trace in some Syrian cigarettes and Its mixtures using voltammetric method on HMDE

    International Nuclear Information System (INIS)

    Nasser, H.; Kabass, H.

    2010-01-01

    This study aims for estimating of trace for these elements in various brands of Syrian Cigarettes and its mixtures, by using voltammetric method (HMDE) hanging mercury drop elec trod. This method is first used to determined Syrian Cigarettes brand and its mixtures, during this study it was found that we can use it easily with low commission, high sensitivity and accurate results comparing with others studies. We prepare the samples by using reference methods. The samples were collected during two times in one year from the same kinds of samples. We noticed that the high concentrations was (3.795μg/g) in Gitanes samples, and the low concentrations in shame samples was (0.37 μg/g). This study refers that there is different concentrations of lead element in this samples.(author)

  3. Leading order determination of the gluon polarisation from DIS events with high-$p_T$ hadron pairs

    CERN Document Server

    Adolph, C; Alexakhin, V Yu; Alexandrov, Yu; Alexeev, G D; Amoroso, A; Antonov, A A; Austregesilo, A; Badelek, B; Balestra, F; Barth, J; Baum, G; Bedfer, Y; Bernhard, J; Bertini, R; Bettinelli, M; Bicker, K; Bieling, J; Birsa, R; Bisplinghoff, J; Bordalo, P; Bradamante, F; Braun, C; Bravar, A; Bressan, A; Burtin, E; Chaberny, D; Chiosso, M; Chung, S U; Cicuttin, A; Crespo, M L; Dalla Torre, S; Das, S; Dasgupta, S S; Denisov, O.Yu; Dhara, L; Donskov, S V; Doshita, N; Duic, V; Dunnweber, W; Dziewiecki, M; Efremov, A; Elia, C; Eversheim, P D; Eyrich, W; Faessler, M; Ferrero, A; Filin, A; Finger, M; jr., M.Finger; Fischer, H; Franco, C; von Hohenesche, N.du Fresne; Friedrich, J M; Garfagnini, R; Gautheron, F; Gavrichtchouk, O P; Gazda, R; Gerassimov, S; Geyer, R; Giorgi, M; Gnesi, I; Gobbo, B; Goertz, S; Grabmuller, S; Grasso, A; Grube, B; Gushterski, R; Guskov, A; Guthorl, T; Haas, F; von Harrach, D; Hedicke, S; Heinsius, F H; Herrmann, F; Hess, C; Hinterberger, F; Horikawa, N; Hoppner, Ch; d'Hose, N; Huber, S; Ishimoto, S; Ivanov, O; Ivanshin, Yu; Iwata, T; Jahn, R; Jasinski, P; Joosten, R; Kabuss, E; Kang, D; Ketzer, B; Khaustov, G V; Khokhlov, Yu.A; Kisselev, Yu; Klein, F; Klimaszewski, K; Koblitz, S; Koivuniemi, J H; Kolosov, V N; Kondo, K; Konigsmann, K; Konorov, I; Konstantinov, V F; Korzenev, A; Kotzinian, A M; Kouznetsov, O; Kramer, M; Kroumchtein, Z V; Kunne, F.; Kurek, K; Lauser, L; Le Goff, J M; Lednev, A A; Lehmann, A; Levorato, S; Lichtenstadt, J; Maggiora, A; Magnon, A; Makke, N; Mallot, G K; Mann, A; Marchand, C; Martin, A; Marzec, J; Matsuda, T; Meyer, W; Michigami, T; Mikhailov, Yu.V; Moinester, M A; Morreale, A; Mutter, A; Nagaytsev, A; Nagel, T; Nassalski, J P; Nerling, F; Neubert, S; Neyret, D; Nikolaenko, V I; Nowak, W D; Nunes, A S; Olshevsky, A G; Ostrick, M; Padee, A; Panknin, R; Panzieri, D; Parsamyan, B; Paul, S.; Perevalova, E; Pesaro, G; Peshekhonov, D V; Piragino, G; Platchkov, S; Pochodzalla, J; Polak, J; Polyakov, V A; Pontecorvo, G; Pretz, J; Procureur, S L; Quaresma, M; Quintans, C; Rajotte, J F; Ramos, S; Rapatsky, V; Reicherz, G; Richter, A; Rocco, E; Rondio, E; Rossiyskaya, N S; Ryabchikov, D I; Samoylenko, V D; Sandacz, A; Sapozhnikov, M G; Sarkar, S.; Savin, I A; Sbrizzai, G; Schiavon, P; Schill, C.; Schluter, T; Schmidt, K; Schmitt, L; Schonning, K; Schopferer, S; Schott, M; Shevchenko, O.Yu; Silva, L; Sinha, L; Sissakian, A N; Slunecka, M; Smirnov, G I; Sosio, S; Sozzi, F; Srnka, A; Stolarski, M; Sulc, M; Sulej, R; Sznajder, P; Takekawa, S; Wolbeek, J.Ter; Tessaro, S; Tessarotto, F; Tkatchev, L G; Uhl, S; Uman, I; Vandenbroucke, M; Virius, M; Vlassov, N V; Wang, L; Windmolders, R; Wislicki, W; Wollny, H; Zaremba, K; Zavertyaev, M; Zemlyanichkina, E; Ziembicki, M; Zhuravlev, N; Zvyagin, A

    2013-01-01

    We present a determination of the gluon polarisation Delta g/g in the nucleon, based on the longitudinal double-spin asymmetry of DIS events with a pair of large transverse-momentum hadrons in the final state. The data were obtained by the COMPASS experiment at CERN using a 160 GeV/c polarised muon beam scattering off a polarised ^6LiD target. The gluon polarisation is evaluated by a Neural Network approach for three intervals of the gluon momentum fraction x_g covering the range 0.04 < x_g < 0.27. The values obtained at leading order in QCD do not show any significant dependence on x_g. Their average is Delta g/g = 0.125 +/- 0.060 (stat.) +/- 0.063 (syst.) at x_g=0.09 and a scale of mu^2 = 3~(GeV/c)^2.

  4. Cadmium and lead determination in foods by beam injection flame furnace atomic absorption spectrometry after ultrasound-assisted sample preparation

    International Nuclear Information System (INIS)

    Aleixo, Poliana Carolina; Junior, Dario Santos; Tomazelli, Andrea Cristina; Rufini, Iolanda A.; Berndt, Harald; Krug, Francisco Jose

    2004-01-01

    A simple method for cadmium and lead determination in foods by beam injection flame furnace atomic absorption spectrometry (BIFF-AAS) was proposed. Food slurries were prepared by transferring an exact amount of cryogenic-ground homogenized material (50-100 mg) to centrifuge tubes, followed by addition of 5 ml (up to 2.8 mol l -1 ) nitric acid solution and sonication in an ultrasonic bath during 5-10 min. Thereafter, slurries were diluted with water to 10 ml, centrifuged during 5 min at 5400 rpm and 400 μl aliquot of the supernatant was analyzed by BIFF-AAS. The detection limits based on peak height measurements were 0.03 μg g -1 Cd and 1.6 μg g -1 Pb for 2% (m/v) slurry (200 mg/10 ml). For method validation, the certified reference materials Pig Kidney (BCR 186) and Rice Flour (NIES 10) were used. Quantitative cadmium and lead recoveries were obtained and no statistical differences were found at 95% level by applying the t-test

  5. Determination of trace amounts of impurities in molybdenum by spark source and glow discharge mass spectrometry

    International Nuclear Information System (INIS)

    Saito, Morimasa

    1994-01-01

    For the determination of trace and ultra-trace amounts of impurities in high-purity molybdenum, spark source mass spectrometry and glow discharge mass spectrometry were studied. In spark source mass spectrometry using the metal probe method, the liquid-helium cryogenic pump was used in order to protect the surface of the samples from oxidation. The theoretical relative sensitivity factors (Mo=1) calculated from physical properties were used. The analytical results obtained for molybdenum tablet and high-purity molybdenum were in good agreement with those obtained by other methods (atomic absorption spectrometry and others). In glow discharge mass spectrometry, the relative sensitivity factors were calculated by using the results obtained by spark source mass spectrometry and atomic absorption spectrometry, and this method was applied to the determination of ultra-trace amounts of impurities in ultra high-purity molybdenum and gave the satisfactory results. The detection limits (2σ, n=10) in the integration time of 600 s for U and Th were 0.6 ppb and 0.3 ppb, and the values for Al, Si, Cr, Mn and Cu were in the range of 10 ppb to 0.5 ppb. (author)

  6. Determination of the growth of nematophagous fungi on diverse carbon sources

    Directory of Open Access Journals (Sweden)

    Martha Orozco

    2015-11-01

    Full Text Available Organic amendments have been widely used to stimulate the populations of predatory nematophagous fungi (PNF in soil; however, the use of organic amendments has produced inconsistent results in the control of parasitic nematodes. The inconsistencies have been partially attributed to the chemical composition of the organic amendments, specifically to carbon and nitrogen contents. Therefore, to know the carbon preferences of these fungi could be helpful to promote the predatory phase of the PNF in soil. The aim of this study was to determine the growth of native PNF strains from Costa Rica in diverse carbon sources. The PNF Arthrobotrys oligospora and Candelabrella musiformis were grown in artificial culture media containing the following carbon sources: cellulose, chitin, pectin, starch, and skim milk. The growth rate developed by the PNF in each one of the culture media was determined and compared. The growth rates developed by both fungal species followed the next order: cellulos e>chitin>pectin>starch>skim milk. Significant differences in the growth rates developed by the fungal strains were detected only in culture medium containing cellulose, in comparison with culture media containing other carbon sources. In culture medium containing cellulose both A. oligospora and C. musiformis grew faster with respect to the other culture media, but A. oligospora strains grew faster in comparison with C. musiformis strains. Both fungal species developed the lowest growth rates in culture media containing starch and skim milk.

  7. Lead Isotope Compositions of Acid Residues from Olivine-Phyric Shergottite Tissint: Implications for Heterogeneous Shergottite Source Reservoirs

    Science.gov (United States)

    Moriwaki, R.; Usui, T.; Yokoyama, T.; Simon, J. I.; Jones, J. H.

    2015-01-01

    Geochemical studies of shergottites suggest that their parental magmas reflect mixtures between at least two distinct geochemical source reservoirs, producing correlations between radiogenic isotope compositions and trace element abundances. These correlations have been interpreted as indicating the presence of a reduced, incompatible element- depleted reservoir and an oxidized, incompatible- element-enriched reservoir. The former is clearly a depleted mantle source, but there is ongoing debate regarding the origin of the enriched reservoir. Two contrasting models have been proposed regarding the location and mixing process of the two geochemical source reservoirs: (1) assimilation of oxidized crust by mantle derived, reduced magmas, or (2) mixing of two distinct mantle reservoirs during melting. The former requires the ancient Martian crust to be the enriched source (crustal assimilation), whereas the latter requires isolation of a long-lived enriched mantle domain that probably originated from residual melts formed during solidification of a magma ocean (heterogeneous mantle model). This study conducts Pb isotope and trace element concentration analyses of sequential acid-leaching fractions (leachates and the final residues) from the geochemically depleted olivine-phyric shergottite Tissint. The results suggest that the Tissint magma is not isotopically uniform and sampled at least two geochemical source reservoirs, implying that either crustal assimilation or magma mixing would have played a role in the Tissint petrogenesis.

  8. Determination of Noise Level and Its Sources in the Neonatal Intensive Care Unit and Neonatal Ward

    Directory of Open Access Journals (Sweden)

    Mahdi Jahangir Blourchian

    2015-12-01

    Full Text Available Background: In Neonatal intensive care units (NICU different sound intensities and frequencies are produced from different sources, which may exert undesirable physiological effects on the infants. The aim of this study was to determine the noise level and its sources in the NICU and neonatal ward of Al-Zahra Hospital of Rasht, Iran. Methods: In this descriptive cross-sectional study, the intensity of the sounds generated by the internal and external sources in the NICU and neonatal ward was measured using a sound level meter device. The sound produced by each of the sources was individually calculated. Data were analyzed performing descriptive and analytical statistics, using SPSS version 19. Results: The mean noise levels in six rooms and a hallway during morning, afternoon and night shifts with the electromechanical devices turned on were 61.67±4.5, 61.32±4.32 and 60.71±4.56 dB, respectively. Moreover, with the devices tuned off the mean noise levels during morning, afternoon and evening shifts were 64.97±2.6, 60.6±1.29 and 57.91±4.73 dB, respectively. The differences between the mean noise levels in the neonatal wards (standard noise level=45 dB during each shift with the electromechanical devices turned on and off were statistically significant (P=0.002 and P

  9. Determinants of epidemiologic transition in rural Africa: the role of socioeconomic status and drinking water source.

    Science.gov (United States)

    Engelaer, Frouke M; Koopman, Jacob J E; van Bodegom, David; Eriksson, Ulrika K; Westendorp, Rudi G J

    2014-06-01

    Many African countries experience a protracted epidemiologic transition, different from the classical transition in western societies. The factors driving this protracted transition are largely unknown. In northeast Ghana, we studied an ongoing epidemiologic transition and investigated the effects of socioeconomic status and drinking water source on the transition. During a 9-year period, we followed a cohort of almost 30 000 individuals and collected information on mortality and fertility rates. In addition, using the standards set out by the WHO, we obtained the causes of death by verbal autopsy. Individuals were stratified according to their socioeconomic status and the households' use of an improved or unimproved drinking water source. Mortality rates decreased by -5.0% annually (pwater source. Factors other than socioeconomic status and drinking water source are responsible for the observed declines in mortality and fertility observed during the protracted epidemiologic transition. Identifying the specific determinants of the ongoing transition is of importance, as they could be targeted in order to further improve public health in rural African countries. © The Author 2014. Published by Oxford University Press on behalf of Royal Society of Tropical Medicine and Hygiene. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  10. High-precision Pb isotopic measurements of teeth and environmental samples from Sofia (Bulgaria): insights for regional lead sources and possible pathways to the human body

    Science.gov (United States)

    Kamenov, George D.

    2008-08-01

    High-precision Pb isotopic measurements on teeth and possible sources in a given area can provide important insights for the lead (Pb) sources and pathways in the human body. Pb isotopic analyses on soils from the area of Sofia, Bulgaria show that Pb is contributed by three end-members represented by two natural sources and leaded gasoline. Sequential leaching experiments reveal that the alumosilicate fraction of the soils is mainly controlled by natural Pb derived from two mountain massifs bordering the city. Around 1/3 to a half of the Pb in the soil leachates, however, can be explained by contamination from leaded gasoline. Contemporary teeth from Sofia residents show very similar Pb isotopic compositions to the soil leachates, also indicating that around 1/3 to a half of the Pb can be explained by derivation from leaded gasoline. The remarkable isotopic similarities between the teeth and the most labile fractions of the local soils suggest that the lead can be derived from the latter. Pb incorporation in the human body via soil-plant-human or soil-plant-animal-human chains is unlikely due to the fact that no significant farming occurs in the city area. The isotopic compositions of the local soil labile fractions can be used as approximation of the bioaccessible lead for humans. Considering all possible scenarios it appears that soil and/or soil-born dust inhalation and/or ingestion is the most probable pathway for incorporation of local soil lead in the local population. The high-precision Pb isotope data presented in this work indicate that apparently the local soil is what plays major role in the human Pb exposure.

  11. Sources

    International Nuclear Information System (INIS)

    Duffy, L.P.

    1991-01-01

    This paper discusses the sources of radiation in the narrow perspective of radioactivity and the even narrow perspective of those sources that concern environmental management and restoration activities at DOE facilities, as well as a few related sources. Sources of irritation, Sources of inflammatory jingoism, and Sources of information. First, the sources of irritation fall into three categories: No reliable scientific ombudsman to speak without bias and prejudice for the public good, Technical jargon with unclear definitions exists within the radioactive nomenclature, and Scientific community keeps a low-profile with regard to public information. The next area of personal concern are the sources of inflammation. This include such things as: Plutonium being described as the most dangerous substance known to man, The amount of plutonium required to make a bomb, Talk of transuranic waste containing plutonium and its health affects, TMI-2 and Chernobyl being described as Siamese twins, Inadequate information on low-level disposal sites and current regulatory requirements under 10 CFR 61, Enhanced engineered waste disposal not being presented to the public accurately. Numerous sources of disinformation regarding low level radiation high-level radiation, Elusive nature of the scientific community, The Federal and State Health Agencies resources to address comparative risk, and Regulatory agencies speaking out without the support of the scientific community

  12. Lead, cadmium and arsenic in human milk and their socio-demographic and lifestyle determinants in Lebanon.

    Science.gov (United States)

    Bassil, Maya; Daou, Farah; Hassan, Hussein; Yamani, Osama; Kharma, Joelle Abi; Attieh, Zouheir; Elaridi, Jomana

    2018-01-01

    Exposure of newborns to toxic metals is of special interest due to their reported contamination in breast milk and potential harm. The aim of this study was to assess the occurrence and factors associated with lead, cadmium and arsenic contamination in breast milk collected from lactating mothers in Lebanon. A total of 74 breast milk samples were collected from primaparas according to guidelines set by the World Health Organization. A survey was administered to determine the demographic and anthropometric characteristics of participating lactating mothers. Dietary habits were assessed using a semi-quantitative food frequency questionnaire. The milk samples were analyzed for the presence of arsenic, cadmium and lead using microwave-assisted digestion and atomic absorption spectrophotometry. Arsenic contamination was found in 63.51% of breast milk samples (mean 2.36 ± 1.95 μg/L) whereas cadmium and lead were detected in 40.54% and 67.61% of samples respectively (means 0.87 ± 1.18 μg/L and 18.18 ± 13.31 μg/L). Regression analysis indicated that arsenic contamination was associated with cereal and fish intake (p = 0.013 and p = 0.042 respectively). Residence near cultivation activities (p = 0.008), smoking status before pregnancy (p = 0.046), potato consumption (p = 0.046) and education level (p = 0.041) were associated with lead contamination. Cadmium contamination was significantly associated with random smoke exposure (p = 0.002). Our study is the first in Lebanon to report toxic metal contamination in breast milk. Although estimated weekly infant intake of these metals from breast milk was found to be lower than the limit set by international guidelines, our results highlight the need for developing strategies to protect infants from exposure to these hazardous substances. Copyright © 2017 Elsevier Ltd. All rights reserved.

  13. Determination of delayed neutrons source in the frequency domain based on in-pile oscillation measurements

    International Nuclear Information System (INIS)

    Yedvab, Y.; Reiss, I.; Bettan, M.; Harari, R.; Grober, A.; Ettedgui, H.; Caspi, E. N.

    2006-01-01

    A method for determining delayed neutrons source in the frequency domain based on measuring power oscillations in a non-critical reactor is presented. This method is unique in the sense that the delayed neutrons source is derived from the dynamic behavior of the reactor, which serves as the measurement system. An algorithm for analyzing power oscillation measurements was formulated, which avoids the need for a multi-parameter non-linear fit process used by other methods. Using this algorithm results of two sets of measurements performed in IRR-I and IRR-II (Israeli Research Reactors I and II) are presented. The agreement between measured values from both reactors and calculated values based on Keepin (and JENDL-3.3) group parameters is very good. (authors)

  14. Applicability of a prototype for determination of absorbed dose using brachytherapy equipment with Ir-192 sources

    International Nuclear Information System (INIS)

    Souza, Vivianne Lucia Bormann; Almeida, Mayara Gabriella Oliveira de; Vieira, Rafaela Etelvina de Amorim; Silva, Waldecy Ananias da; Nascimento, Rizia Keila

    2014-01-01

    This work aims at the development and improvement of a device to perform the absolute dosimetry sources of Ir-192 using the Fricke solution contained in a flask. The Fricke solution used was prepared using amounts of ferrous ammonium sulfate, sodium chloride and sulfuric acid, diluted with water tri distilled pre-established in the literature. The spectrophotometer used was a UV-VIS spectrophotometer (Beckman DU-640 Counter) for measuring the optical density at wavelength 304 nm. The calculation for determining the radial dose takes into account the radial distance and the angle formed with the transverse axis of the source. As the results obtained can be seen that the states of Pernambuco, Ceara, Paraiba e Piaui are in accordance with the recommendations of international standards of the International Atomic Energy Agency (IAEA), which considers not acceptable a difference greater than 5% of prescribed dose and measured dose

  15. An attempt to determine positions of aerosol source by the PIXE analysis

    International Nuclear Information System (INIS)

    Matsuyama, S.; Tokai, Y.; Ishii, K.

    1999-01-01

    Aerosols were continuously collected for 2 or 3 hours during the periods of 4-27 August 1997 and of 23 March-2 April 1998 at a suburb of Sendai City (east 10 km from Sendai), and meteorological data such as wind directions, wind velocities, etc were measured at the same time. The collected aerosol samples were analyzed by the particle-induced X-ray emission (PIXE) method. Fourteen elements (S, Cl, K, Ca, Ti, V, Cr, Mn, Fe, Ni, Cu, Zn, Hg and Pb) were contained in these samples. The elemental concentrations increased in the daytime and decreased at night. It coincided with the time variation of people movement. The concentrations of Mn, Fe, Zn and Pb elements depended strongly on the direction of wind and their distributions for wind directions reflected to the position of aerosol sources. This result suggests that the position of aerosol source can be determined by measuring aerosols and wind directions at the many positions. (author)

  16. Occurrence of lead, copper, zinc, and arsenic compounds in atmospheric dusts, and the sources of these impurities

    Energy Technology Data Exchange (ETDEWEB)

    Dunn, J T; Bloxam, H C.L.

    1933-06-30

    The authors indicate that the combustion of fossil fuels such as coal for industrial and electrical power causes the deposition of zinc, arsenic, copper, and lead which are then found in the dust and soots of most urban areas. They express the fear that these dusts, if not poisonous, may be expected to be injurious to the health of man, animals, and plants.

  17. Features of the low-power charge controller of lead-acid current sources charged by solar batteries

    International Nuclear Information System (INIS)

    Tukfatullin, O.F.; Yuldoshev, I.A.; Solieva, N.A.

    2008-01-01

    Influence of different factors on exploitations characteristics of solar photoelectric plant is investigated by field-performance data. A construction of charge controller of the lead-acid accumulator battery charging by means of solar battery is analyzed taking into account these factors. (authors)

  18. Determination of trace element concentrations and stable lead, uranium and thorium isotope ratios by quadrupole-ICP-MS in NORM and NORM-polluted sample leachates

    Energy Technology Data Exchange (ETDEWEB)

    Mas, J.L., E-mail: ppmasb@us.es [Dpto. Fisica Aplicada I, EPS, Universidad de Sevilla, 41012 Sevilla (Spain); Villa, M. [Servicio de Radioisotopos, Centro de Investigacion, Tecnologia e Innovacion (CITIUS), Universidad de Sevilla, Avda. Reina Mercedes 4b, 41012 Sevilla (Spain); Dpto. Fisica Aplicada II, ETS de Arquitectura, Universidad de Sevilla, Avda. Reina Mercedes 2, 41012 Sevilla (Spain); Hurtado, S. [Servicio de Radioisotopos, Centro de Investigacion, Tecnologia e Innovacion (CITIUS), Universidad de Sevilla, Avda. Reina Mercedes 4b, 41012 Sevilla (Spain); Garcia-Tenorio, R. [Dpto. Fisica Aplicada II, ETS de Arquitectura, Universidad de Sevilla, Avda. Reina Mercedes 2, 41012 Sevilla (Spain)

    2012-02-29

    Highlights: Black-Right-Pointing-Pointer Polluted sediment and NORM samples. Black-Right-Pointing-Pointer An efficient yet fast process allowing multi-parametric determinations in <3 days. Black-Right-Pointing-Pointer Trace element concentrations, Pb, Th and U isotope ratios with a single instrument. - Abstract: This work focuses on the monitoring of the potential pollution in scenarios that involve NORM-related industrial activities (environmental or in-door scenarios). The objective was to develop a method to determine extent and origin of the contamination, suitable for monitoring (i.e. simple, fast and economical) and avoiding the use of too many different instruments. It is presented a radiochemical method that allows the determination of trace element concentrations and {sup 206}Pb/{sup 207}Pb/{sup 208}Pb, {sup 238}U/{sup 234}U and {sup 232}Th/{sup 230}Th isotope ratios using a single sample aliquot and a single instrument (ICP-QMS). Eichrom UTEVA{sup Registered-Sign} extraction chromatography minicolumns were used to separate uranium and thorium in sample leachates. Independent ICP-MS determinations of uranium and thorium isotope ratios were carried out afterwards. Previously a small aliquot of the leachate was used for the determination of trace element concentrations and lead isotope ratios. Several radiochemical arrangements were tested to get maximum performances and simplicity of the method. The performances of the method were studied in terms of chemical yields of uranium and thorium and removal of the potentially interfering elements. The established method was applied to samples from a chemical industry and sediments collected in a NORM-polluted scenario. The results obtained from our method allowed us to infer not only the extent, but also the sources of the contamination in the area.

  19. Exploring the uncertainty in attributing sediment contributions in fingerprinting studies due to uncertainty in determining element concentrations in source areas.

    Science.gov (United States)

    Gomez, Jose Alfonso; Owens, Phillip N.; Koiter, Alex J.; Lobb, David

    2016-04-01

    determine an average value for each of the different maps of element concentration and sub-catchment, under different sampling densities: 200 different average values for the "high" sampling density (average of 50 samples); 400 different average values for the "medium" sampling density (average of 25 samples); and 1,000 different average values for the "low" sampling density (average of 10 samples). All these combinations of possible values of element concentrations in the source areas were solved for the concentration in the sediment already determined for the "true" solution using limSolve (Soetaert et al., 2014) in R language. The sediment source solutions found for the different situations and values were analyzed in order to: 1) evaluate the uncertainty in the sediment source attribution; and 2) explore strategies to detect the most probable solutions that might lead to improved methods for constructing the most robust mixing models. Preliminary results on these will be presented and discussed in this communication. Key words: sediment, fingerprinting, uncertainty, variability, mixing model. References Collins, A.L., Zhang, Y., McChesney, D., Walling, D.E., Haley, S.M., Smith, P. 2012. Sediment source tracing in a lowland agricultural catchment in southern England using a modified procedure combining statistical analysis and numerical modelling. Science of the Total Environment 414: 301-317. Freeze, R.A. 1980. A stochastic-conceptual analysis of rainfall-runoff processes on a hillslope. Water Resources Research 16: 391-408.

  20. Using Monoclonal Antibody to Determine Lead Ions with a Localized Surface Plasmon Resonance Fiber-optic Biosensor

    Directory of Open Access Journals (Sweden)

    Mon-Fu Chung

    2008-01-01

    Full Text Available A novel reflection-based localized surface plasmon resonance (LSPR fiber-optic probe has been developed to determine the heavy metal lead ion concentration. Monoclonal antibody as the detecting probe containing massive amino groups to capture Pb(II-chelate complexes was immobilized onto gold nanoparticle-modified optical fiber (NMAuOF. The optimal immobilizing conditions of monoclonal antibody on to the NMAuOF are 189 μg/mL in pH7.4 PBS for 2 h at 25°C. The absorbability of the functionalized NMAuOF sensor increases to 12.2 % upon changing the Pb(II-EDTA level from 10 to 100 ppb with a detection limit of 0.27 ppb. The sensor retains 92.7 % of its original activity and gives reproducible results after storage in 5% D-( -Trehalose dehydrate solution at 4°C for 35 days. In conclusion, the monoclonal antibody-functionalized NMAuOF sensor shows a promising result for determining the concentration of Pb(II with high sensitivity.

  1. Lead Isotopes in Olivine-Phyric Shergottite Tissint: Implications for the Geochemical Evolution of the Shergottite Source Mantle

    Science.gov (United States)

    Moriwaki, R.; Usui, T.; Simon, J. I.; Jones, J. H.; Yokoyama, T.

    2015-01-01

    Geochemically-depleted shergottites are basaltic rocks derived from a martian mantle source reservoir. Geochemical evolution of the martian mantle has been investigated mainly based on the Rb-Sr, Sm-Nd, and Lu-Hf isotope systematics of the shergottites [1]. Although potentially informative, U-Th- Pb isotope systematics have been limited because of difficulties in interpreting the analyses of depleted meteorite samples that are more susceptible to the effects of near-surface processes and terrestrial contamination. This study conducts a 5-step sequential acid leaching experiment of the first witnessed fall of the geochemically-depleted olivinephyric shergottite Tissint to minimize the effect of low temperature distrubence. Trace element analyses of the Tissint acid residue (mostly pyroxene) indicate that Pb isotope compositions of the residue do not contain either a martian surface or terrestrial component, but represent the Tissint magma source [2]. The residue has relatively unradiogenic initial Pb isotopic compositions (e.g., 206Pb/204Pb = 10.8136) that fall within the Pb isotope space of other geochemically-depleted shergottites. An initial µ-value (238U/204Pb = 1.5) of Tissint at the time of crystallization (472 Ma [3]) is similar to a time-integrated mu- value (1.72 at 472 Ma) of the Tissint source mantle calculated based on the two-stage mantle evolution model [1]. On the other hand, the other geochemically-depleted shergottites (e.g., QUE 94201 [4]) have initial µ-values of their parental magmas distinctly lower than those of their modeled source mantle. These results suggest that only Tissint potentially reflects the geochemical signature of the shergottite mantle source that originated from cumulates of the martian magma ocean

  2. Experimental determination of the neutron source for the Argonauta reactor subcritical assembly

    Energy Technology Data Exchange (ETDEWEB)

    Renke, Carlos A.C.; Furieri, Rosanne C.A.A.; Pereira, Joao C.S.; Voi, Dante L.; Barbosa, Andre L.N., E-mail: renke@ien.gov.b [Instituto de Engenharia Nuclear (IEN/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2011-07-01

    The utilization of a subcritical assembly for the determination of nuclear parameters in a multiplier medium requires a well defined neutron source to carry out the experiments necessary for the acquisition of the desired data. The Argonauta research reactor installed at the Instituto de Engenharia Nuclear has a subcritical assembly, under development, to be coupled at the upper part of the reactor core that will provide the needed neutrons emerging from its internal thermal column made of graphite. In order to perform neutronic calculations to compare with the experimental results, it is necessary a precise knowledge of the emergent neutron flux that will be used as neutron source in the subcritical assembly. In this work, we present the thermal neutron flux profile determined experimentally via the technique of neutron activation analysis, using dysprosium wires uniformly distributed at the top of the internal thermal neutron column of the Argonauta reactor and later submitted to a detection system using Geiger-Mueller detector. These experimental data were then compared with those obtained through neutronic calculation using HAMMER and CITATION codes in order to validate this calculation system and to define a correct neutron source distribution to be used in the subcritical assembly. This procedure avoids a coupled neutronic calculation of the subcritical assembly and the reactor core. It has also been determined the dimension of the graphite pedestal to be used in the bottom of the subcritical assembly tank in order to smooth the emergent neutron flux at the reactor top. Finally, it is estimated the thermal neutron flux inside the assembly tank when filled with water. (author)

  3. Set of programs for determining exposure and dose rates from selected sources of gamma radiation

    International Nuclear Information System (INIS)

    Hep, J.; Kralovcova, E.; Smutny, V.; Valenta, V.

    1982-01-01

    The programs are described for the determination of exposure and dose rate of gamma radiation from point, surface, linear and volume sources with and without shielding. The computation is conducted using the classical method taking into consideration the buildup factor. For the computation of the buildup factor in heterogeneous shielding the Broder and Kitazuma formulas are used. Kitazuma's alpha coefficients were calculated recurrently using a new semi-empirical method. Taylor's approximation was used for the calculation of the buildup factor in a single layer

  4. Determination of radium isotopes by BaSO4 coprecipitation for the preparation of alpha-spectrometric sources

    International Nuclear Information System (INIS)

    Lozano, J.C.; Fernandez, F.; Gomez, J.M.G.

    1997-01-01

    A coprecipitation procedure for the preparation of α-spectrometric sources for radium, using BaSO 4 as carrier, has been applied to the determination of alpha radium isotopes in water samples. The use of 133 Ba as a suitable tracer for radium determination and possible losses of radon isotopes from the sources are studied and discussed. (author)

  5. DETERMINANTS OF THE ACCURACY OF NURSING DIAGNOSES : INFLUENCE OF READY KNOWLEDGE, KNOWLEDGE SOURCES, DISPOSITION TOWARD CRITICAL THINKING, AND REASONING SKILLS

    NARCIS (Netherlands)

    Paans, Wolter; Sermeus, Walter; Nieweg, Roos; Van der Schans, Cees

    2010-01-01

    The purpose of this study was to determine how knowledge sources, ready knowledge, and disposition toward critical thinking and reasoning skills influence the accuracy of student nurses' diagnoses. A randomized controlled trial was conducted to determine the influence of knowledge sources. We used

  6. Determinants of the accuracy of nursing diagnoses : influence of ready knowledge, knowledge sources, disposition toward critical thinking, and reasoning skills

    NARCIS (Netherlands)

    Paans, Wolter; Sermeus, Walter; Nieweg, Roos; van der Schans, Cees

    2010-01-01

    The purpose of this study was to determine how knowledge sources, ready knowledge, and disposition toward critical thinking and reasoning skills influence the accuracy of student nurses' diagnoses. A randomized controlled trial was conducted to determine the influence of knowledge sources. We used

  7. Simultaneous Determination of Source Wavelet and Velocity Profile Using Impulsive Point-Source Reflections from a Layered Fluid

    National Research Council Canada - National Science Library

    Bube, K; Lailly, P; Sacks, P; Santosa, F; Symes, W. W

    1987-01-01

    .... We show that a quasi-impulsive, isotropic point source may be recovered simultaneously with the velocity profile from reflection data over a layered fluid, in linear (perturbation) approximation...

  8. Quantitative determination of iron, copper, lead, chromium and nickel in electronic waste samples using total reflection x-ray fluorescence spectroscopy

    International Nuclear Information System (INIS)

    Elaseer, A. S.; Musbah, A. S; Ammar, M. M. G.; Salah, M. A.; Aisha, E. A.

    2015-01-01

    Total reflection x-ray fluorescence spectroscopy in conjunction with microwave assisted extraction technique was used for the analysis of twenty electronic waste samples. The analysis was limited to the printed circuit boards of electronic devices. Iron, copper, lead, chromium and nickel were quantitatively determined in the samples. The samples were carefully milled to fine powder and 50mg was digested by acid using microwave digestion procedure. The digested samples solution was spread together with gallium as internal standard on the reflection disk and analyzed. The results showed that the cassette recorder boards contain the highest concentration of iron, lead and nickel. The average concentrations of these metals were 78, 73 and 71g/Kg respectively. Computer boards contained the highest copper average concentration 39g/Kg. the highest chromium average concentration 3.6 g/Kg was in mobile phone boards. Measurements were made using PicoTAX portable x-ray device. the instrument was used for quantitative multi-element analysis. An air cooled x-ray tube (40KV, 1 mA) with Mo target and Be window was used as x-ray source. The optics of the device was a multilayer Ni/C, 17.5 keV, 80% reflectivity provides analysis of elements from Si to Zr (K series) and Rh to U (L series). A Si PIN-diode detector (7mm"2, 195eV) was used for the elements detection. In this study heavy metals average concentration in electronic circuit boards in the in the order of iron (35.25g/kg), copper (21.14g/Kg), lead (16.59g/Kg), nickel (16.01g/Kg) and chromium (1.07g/Kg).(author)

  9. Tracers application method for the quantitative determination of the source of oxygenic inclusions in steel

    International Nuclear Information System (INIS)

    Rewienska-Kosciukowa, B.; Dalecki, W.; Michalik, J.S.

    1976-01-01

    The sense and the possibility of radioactive and nonradioactive isotopic tracers application in investigations of the origin of oxygenic nonmetalic inclusions is presented. The discussed methods touch the investigations such as the origin of egzogenic inclusions which passed from external sources (fireproof lining, slag) to the steel or as the endogenic ones formed during the process of steel deoxidisation. The question of the tracers choice for refractory material and the further investigations concerned the determination of the origin of nonmetallic inclusions are discussed. The question of so called isotopic replacement tracers for the main steel deoxidizing agents is considered. The criterion of determination of oxygenic inclusions formed during the process of steel deoxidization is also discussed. Several results of laboratory and industrial investigations and also the examples of application of the discussed methods in the industrial scale are presented. (author)

  10. Choice of excitation source for determination of rare earth elements with radioisotope excited X ray fluorescence

    International Nuclear Information System (INIS)

    Zhang Quanshi; Chang Yongfu

    2000-01-01

    The comparisons of two radioisotope source ( 241 Am and 238 Pu) which are the most available in the radioisotope excited X Ray Fluorescence (XRF) analysis technique and two characteristic X ray series (KX and LX) analyzed for the determination of the rare-earth (RE) elements were investigated in detail. According to the principle of emission and detection of X ray , the relative excitation efficiencies were calculated by the some fundamental physical parameters including the photoelectric mass attenuation coefficient, the fluorescent yield, the absorption jump factor, the emission probability of the detected fluorescent line with reference to other liens of the same series etc., The advantages and disadvantages of the two conditions are discussed. These results may determine the optimal excitation and detection conditions for different rare-earth elements. The experimental results with nine rare-earth elements (Ce, Nd, Sm, Tb, Tm, Ho, Er, Yb and Lu) are in agreement with the results of theoretical calculations

  11. Determination, Source Identification and GIS Mapping for Nitrate Concentration in Groundwater from Bara Aquifer

    Energy Technology Data Exchange (ETDEWEB)

    Elami, G. M.; Sam, A. K.; Yagob, T. I.; Siddeeg, S. E.M.B.; Hatim, E.; Hajo, I. [Sudan Atomic Energy Commission, Sudan, Khartoum (Sudan)

    2013-07-15

    This study was carried out to determine the level of nitrate concentration in well water from Bara aquifer in north Kordofan state (west central sudan). The analysis was conducted for 69 wells from different villages within the Bara basin. Spectophotometric analysis was used to determine nitrate, nitrite and ammonia. Results revealed that nitrate concentration range was from 9.68 to 891 mg L in the sampled well with 81% exceeding the maximum permissible limits set for drinking water by WHO and SSMO. Animal waste and organic soil nitrogen were found to be the source of nitrate in these wells as indicated by {sup 15}N. The majority of wells with high nitrate are in the north and the north east part of the study area are shown by the GIS predictive map. (author)

  12. Determination of sources and analysis of micro-pollutants in drinking water

    International Nuclear Information System (INIS)

    Md Pauzi Abdullah; Soh Shiau Chian

    2005-01-01

    The objectives of the study are to develop and validate selected analytical methods for the analysis of micro organics and metals in water; to identify, monitor and assess the levels of micro organics and metals in drinking water supplies; to evaluate the relevancy of the guidelines set in the National Standard of Drinking Water Quality 2001; and to identify the sources of pollution and to carryout risk assessment of exposure to drinking water. The presentation discussed the progress of the work include determination of VOCs (Volatile organic compounds) in drinking water using SPME (Solid phase micro-extraction) extraction techniques, analysis of heavy metals in drinking water, determination of Cr(VI) with ICPES (Inductively coupled plasma emission spectrometry) and the presence of halogenated volatile organic compounds (HVOCs), which is heavily used by agricultural sector, in trace concentrations in waters

  13. Sequential extraction procedure for determination of uranium, thorium, radium, lead and polonium radionuclides by alpha spectrometry in environmental samples

    Science.gov (United States)

    Oliveira, J. M.; Carvalho, F. P.

    2006-01-01

    A sequential extraction technique was developed and tested for common naturally-occurring radionuclides. This technique allows the extraction and purification of uranium, thorium, radium, lead, and polonium radionuclides from the same sample. Environmental materials such as water, soil, and biological samples can be analyzed for those radionuclides without matrix interferences in the quality of radioelement purification and in the radiochemical yield. The use of isotopic tracers (232U, 229Th, 224Ra, 209Po, and stable lead carrier) added to the sample in the beginning of the chemical procedure, enables an accurate control of the radiochemical yield for each radioelement. The ion extraction procedure, applied after either complete dissolution of the solid sample with mineral acids or co-precipitation of dissolved radionuclide with MnO2 for aqueous samples, includes the use of commercially available pre-packed columns from Eichrom® and ion exchange columns packed with Bio-Rad resins, in altogether three chromatography columns. All radioactive elements but one are purified and electroplated on stainless steel discs. Polonium is spontaneously plated on a silver disc. The discs are measured using high resolution silicon surface barrier detectors. 210Pb, a beta emitter, can be measured either through the beta emission of 210Bi, or stored for a few months and determined by alpha spectrometry through the in-growth of 210Po. This sequential extraction chromatography technique was tested and validated with the analysis of certified reference materials from the IAEA. Reproducibility was tested through repeated analysis of the same homogeneous material (water sample).

  14. Determination of temperature dependency of material parameters for lead-free alkali niobate piezoceramics by the inverse method

    Directory of Open Access Journals (Sweden)

    K. Ogo

    2016-06-01

    Full Text Available Sodium potassium niobate (NKN piezoceramics have been paid much attention as lead-free piezoelectric materials in high temperature devices because of their high Curie temperature. The temperature dependency of their material parameters, however, has not been determined in detail up to now. For this purpose, we exploit the so-called Inverse Method denoting a simulation-based characterization approach. Compared with other characterization methods, the Inverse Method requires only one sample shape of the piezoceramic material and has further decisive advantages. The identification of material parameters showed that NKN is mechanically softer in shear direction compared with lead zirconate titanate (PZT at room temperature. The temperature dependency of the material parameters of NKN was evaluated in the temperature range from 30 °C to 150 °C. As a result, we figured out that dielectric constants and piezoelectric constants show a monotonous and isotropic increment with increasing temperature. On the other hand, elastic stiffness constant c 44 E of NKN significantly decreased in contrast to other elastic stiffness constants. It could be revealed that the decrement of c 44 E is associated with an orthorhombic-tetragonal phase transition. Furthermore, ratio of elastic compliance constants s 44 E / s 33 E exhibited similar temperature dependent behavior to the ratio of piezoelectric constants d15/d33. It is suspected that mechanical softness in shear direction is one origin of the large piezoelectric shear mode of NKN. Our results show that NKN are suitable for high temperature devices, and that the Inverse Method should be a helpful approach to characterize material parameters under their practical operating conditions for NKN.

  15. Mercury isotope constraints on the source for sediment-hosted lead-zinc deposits in the Changdu area, southwestern China

    Science.gov (United States)

    Xu, Chunxia; Yin, Runsheng; Peng, Jiantang; Hurley, James P.; Lepak, Ryan F.; Gao, Jianfeng; Feng, Xinbin; Hu, Ruizhong; Bi, Xianwu

    2018-03-01

    The Lanuoma and Cuona sediment-hosted Pb-Zn deposits hosted by Upper Triassic limestone and sandstone, respectively, are located in the Changdu area, SW China. Mercury concentrations and Hg isotopic compositions from sulfide minerals and potential source rocks (e.g., the host sedimentary rocks and the metamorphic basement) were investigated to constrain metal sources and mineralization processes. In both deposits, sulfide minerals have higher mercury (Hg) concentrations (0.35 to 1185 ppm) than the metamorphic basement rocks (0.05 to 0.15 ppm) and sedimentary rocks (0.02 to 0.08 ppm). Large variations of mass-dependent fractionation (3.3‰ in δ202Hg) and mass-independent fractionation (0.3‰ in Δ199Hg) of Hg isotopes were observed. Sulfide minerals have Hg isotope signatures that are similar to the hydrothermal altered rocks around the deposit, and similar to the metamorphic basement, but different from barren sedimentary rocks. The variation of Δ199Hg suggests that Hg in sulfides was mainly derived from the underlying metamorphic basement. Mercury isotopes could be a geochemical tracer in understanding metal sources in hydrothermal ore deposits.

  16. sources

    Directory of Open Access Journals (Sweden)

    Shu-Yin Chiang

    2002-01-01

    Full Text Available In this paper, we study the simplified models of the ATM (Asynchronous Transfer Mode multiplexer network with Bernoulli random traffic sources. Based on the model, the performance measures are analyzed by the different output service schemes.

  17. Determination of Key Risk Supervision Areas around River-Type Water Sources Affected by Multiple Risk Sources: A Case Study of Water Sources along the Yangtze’s Nanjing Section

    Directory of Open Access Journals (Sweden)

    Qi Zhou

    2017-02-01

    Full Text Available To provide a reference for risk management of water sources, this study screens the key risk supervision areas around river-type water sources (hereinafter referred to as the water sources threatened by multiple fixed risk sources (the risk sources, and establishes a comprehensive methodological system. Specifically, it comprises: (1 method of partitioning risk source concentrated sub-regions for screening water source perimeter key risk supervision areas; (2 approach of determining sub-regional risk indexes (SrRI, which characterizes the scale of sub-regional risks considering factors like risk distribution intensity within sub-regions, risk indexes of risk sources (RIRS, characterizing the risk scale of risk sources and the number of risk sources; and (3 method of calculating sub-region’s risk threats to the water sources (SrTWS which considers the positional relationship between water sources and sub-regions as well as SrRI, and the criteria for determining key supervision sub-regions. Favorable effects are achieved by applying this methodological system in determining water source perimeter sub-regions distributed along the Yangtze’s Nanjing section. Results revealed that for water sources, the key sub-regions needing supervision were SD16, SD06, SD21, SD26, SD15, SD03, SD02, SD32, SD10, SD11, SD14, SD05, SD27, etc., in the order of criticality. The sub-region with the greatest risk threats on the water sources was SD16, which was located in the middle reaches of Yangtze River. In general, sub-regions along the upper Yangtze reaches had greater threats to water sources than the lower reach sub-regions other than SD26 and SD21. Upstream water sources were less subject to the threats of sub-regions than the downstream sources other than NJ09B and NJ03.

  18. Determination of trace amounts of lead by chelating ion exchange and on-line preconcentration in flow-injection atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Purohit, Rajesh; Devi, Surekha

    1992-01-01

    Resins synthesized from quinolin-8-ol and resorcinol or hydro-quinone, with furfuraldehyde, formaldehyde or benzaldehyde as cross-linking agent, were used for the preconcentration of nanogram amounts of lead. The rate of exchange and activation energy of lead exchange were calculated. Column separations of lead-copper and lead-zinc did not show any cross-contamination. A continuous flow manifold using resin microcolumns was developed for the preconcentration and determination of lead. (author). 24 refs.; 5 figs.; 3 tabs

  19. Determinants of Internet use as a preferred source of information on personal health.

    Science.gov (United States)

    Lemire, Marc; Paré, Guy; Sicotte, Claude; Harvey, Charmian

    2008-11-01

    To understand the personal, social and cultural factors likely to explain recourse to the Internet as a preferred source of personal health information. A cross-sectional survey was conducted among a population of 2923 Internet users visiting a firmly established website that offers information on personal health. Multiple regression analysis was performed to identify the determinants of site use. The analysis template comprised four classes of determinants likely to explain Internet use: beliefs, intentions, user satisfaction and socio-demographic characteristics. Seven-point Likert scales were used. An analysis of the psychometric qualities of the variables provided compelling evidence of the construct's validity and reliability. A confirmatory factor analysis confirmed the correspondence with the factors predicted by the theoretical model. The regression analysis explained 35% of the variance in Internet use. Use was directly associated with five factors: perceived usefulness, importance given to written media in searches for health information, concern for personal health, importance given to the opinions of physicians and other health professionals, and the trust placed in the information available on the site itself. This study confirms the importance of the credibility of information on the frequency of Internet use as a preferred source of information on personal health. It also shows the potentially influential role of the Internet in the development of personal knowledge of health issues.

  20. Problems in Determination of Skeletal Lead Burden in Archaeological Samples: An Example From the First African Baptist Church Population

    International Nuclear Information System (INIS)

    Whittmers, L.E. Jr.; Aufderheide, A.C.; Pounds, Joel G.; Jones, Keith; Angel, J.L.

    2008-01-01

    Human bone lead content has been demonstrated to be related to socioeconomic status, occupation and other social and environmental correlates. Skeletal tissue samples from 135 individuals from an early nineteenth century Philadelphia cemetery (First African Baptist Church) were studied by electrothermal atomic absorption spectrometry and x-ray fluorescence for lead content. High bone lead levels led to investigation of possible diagenetic effects. These were investigated by several different approaches including distribution of lead within bone by x-ray fluorescence, histological preservation, soil lead concentration and acidity as well as location and depth of burial. Bone lead levels were very high in children, exceeding those of the adult population that were buried in the cemetery, and also those of present day adults. The antemortem age-related increase in bone lead, reported in other studies, was not evidenced in this population. Lead was even deposited in areas of taphonomic bone destruction. Synchrotron x-ray fluorescence studies revealed no consistent pattern of lead microdistribution within the bone. Our conclusions are that postmortem diagenesis of lead ion has penetrated these archaeological bones to a degree that makes their original bone lead content irretrievable by any known method. Increased bone porosity is most likely responsible for the very high levels of lead found in bones of newborns and children

  1. Functional group composition of ambient and source organic aerosols determined by tandem mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Dron, J.; El Haddad, I.; Temime-Roussel, B.; Wortham, H.; Marchand, N. [Univ Aix Marseille, CNRS, Lab Chim Provence, Equipe Instrumentat and React Atmospher, UMR 6264, F-13331 Marseille 3 (France); Jaffrezo, J.L. [Univ Grenoble 1, CNRS, UMR 5183, Lab Glaciol and Geophys Environm, F-38402 St Martin Dheres (France)

    2010-07-01

    The functional group composition of various organic aerosols (OA) is investigated using a recently developed analytical approach based on atmospheric pressure chemical ionisation-tandem mass spectrometry (APCIMS/MS). The determinations of three functional groups contents are performed quantitatively by neutral loss (carboxylic and carbonyl groups, R-COOH and R-CO-R' respectively) and precursor ion (nitro groups, R-NO{sub 2}) scanning modes of a tandem mass spectrometer. Major organic aerosol sources are studied: vehicular emission and wood combustion for primary aerosol sources; and a secondary organic aerosol (SOA) produced through photooxidation of o-xylene. The results reveal significant differences in the functional group contents of these source aerosols. The laboratory generated SOA is dominated by carbonyls while carboxylics are preponderate in the wood combustion particles. On the other hand, vehicular emissions are characterised by a strong nitro content. The total amount of the three functional groups accounts for 1.7% (vehicular) to 13.5% (o-xylene photooxidation) of the organic carbon. Diagnostic functional group ratios are then used to tentatively discriminate sources of particles collected in an urban background environment located in an Alpine valley (Chamonix, France) during a strong winter pollution event. The three functional groups under study account for a total functionalization rate of 2.2 to 3.8% of the organic carbon in this ambient aerosol, which is also dominated by carboxylic moieties. In this particular case study of a deep alpine valley during winter, we show that the nitro- and carbonyl-to-carboxylic diagnostic ratios can be a useful tool to discriminate sources. In these conditions, the total OA concentrations are highly dominated by wood combustion OA. This result is confirmed by an organic markers source apportionment approach which assess a wood burning organic carbon contribution of about 60%. Finally, examples of functional

  2. Functional group composition of ambient and source organic aerosols determined by tandem mass spectrometry

    Directory of Open Access Journals (Sweden)

    J. Dron

    2010-08-01

    Full Text Available The functional group composition of various organic aerosols (OA is investigated using a recently developed analytical approach based on atmospheric pressure chemical ionisation-tandem mass spectrometry (APCI-MS/MS. The determinations of three functional groups contents are performed quantitatively by neutral loss (carboxylic and carbonyl groups, R-COOH and R-CO-R´ respectively and precursor ion (nitro groups, R-NO2 scanning modes of a tandem mass spectrometer. Major organic aerosol sources are studied: vehicular emission and wood combustion for primary aerosol sources; and a secondary organic aerosol (SOA produced through photooxidation of o-xylene. The results reveal significant differences in the functional group contents of these source aerosols. The laboratory generated SOA is dominated by carbonyls while carboxylics are preponderate in the wood combustion particles. On the other hand, vehicular emissions are characterised by a strong nitro content. The total amount of the three functional groups accounts for 1.7% (vehicular to 13.5% (o-xylene photooxidation of the organic carbon. Diagnostic functional group ratios are then used to tentatively discriminate sources of particles collected in an urban background environment located in an Alpine valley (Chamonix, France during a strong winter pollution event. The three functional groups under study account for a total functionalisation rate of 2.2 to 3.8% of the organic carbon in this ambient aerosol, which is also dominated by carboxylic moieties. In this particular case study of a deep alpine valley during winter, we show that the nitro- and carbonyl-to-carboxylic diagnostic ratios can be a useful tool to discriminate sources. In these conditions, the total OA concentrations are highly dominated by wood combustion OA. This result is confirmed by an organic markers source apportionment approach which assess a wood burning organic carbon contribution of about 60

  3. Determining the sources of calcium for migratory songbirds using stable strontium isotopes.

    Science.gov (United States)

    Blum, Joel D; Taliaferro, E Hank; Holmes, Richard T

    2001-02-01

    We investigated natural variations in the stable isotopic composition of strontium (a surrogate for calcium) in the bones of a single species of breeding migratory songbird, as well as in their eggshells, egg contents, and food sources. We use this information to determine the sources of calcium to these migratory songbirds and their offspring. Samples were collected from two locations in the northeastern USA (Hubbard Brook, NH, and Downer Forest, VT.) that differed in soil geochemistry. The mean 87 Sr/ 86 Sr ratios of food items (caterpillars and snails), eggshells, and egg contents were indistinguishable within each site, but significantly different between the two sites. Mean 87 Sr/ 86 Sr ratios for the bones of adult females were significantly different between the two sites, but values were significantly lower than those of food items and eggshells at each site. Two of four adult individuals studied at each site had 87 Sr/ 86 Sr ratios lower than the entire range of values for local food sources. Mixing calculations indicate that up to 60% of skeletal strontium and calcium was derived from foods consumed in the winter grounds where lower 87 Sr/ 86 Sr ratios predominate. At each study site, the 87 Sr/ 86 Sr ratio of eggshells differed significantly between clutches, but the mean clutch 87 Sr/ 86 Sr ratios were unrelated to the skeletal 87 Sr/ 86 Sr ratio of the laying adult. These findings suggest that strontium (and hence calcium) for eggshell production in this species is derived predominantly from local food sources in breeding areas. Thus, reductions in available calcium in northern temperate ecosystems due to the influences of acid deposition could be potentially harmful to this and other species of migratory bird.

  4. Determining the nature of faint X-ray sources from the ASCA Galactic center survey

    Science.gov (United States)

    Lutovinov, A. A.; Revnivtsev, M. G.; Karasev, D. I.; Shimansky, V. V.; Burenin, R. A.; Bikmaev, I. F.; Vorob'ev, V. S.; Tsygankov, S. S.; Pavlinsky, M. N.

    2015-05-01

    We present the results of the the identification of six objects from the ASCA Galactic center and Galactic plane surveys: AX J173548-3207, AX J173628-3141, AX J1739.5-2910, AX J1740.4-2856, AX J1740.5-2937, and AX J1743.9-2846. Chandra, XMM-Newton, and XRT/Swift X-ray data have been used to improve the positions of the optical counterparts to these sources. Thereafter, we have carried out a series of spectroscopic observations of the established optical counterparts at the RTT-150 telescope. Analysis of X-ray and optical spectra as well as photometric measurements in a wide wavelength range based on optical and infrared catalogs has allowed the nature of the program sources to be determined. Two X-ray objects have been detected in the error circle of AX J173628-3141: one is a coronally active G star and the other may be a symbiotic star, a red giant with an accreting white dwarf. Three sources (AX J1739.5-2910, AX J1740.5-2937, AX J1743.9-2846) have turned out to be active G-K stars, presumably RS CVn objects, one (AX J1740.4-2856) is an M dwarf, and another one (AX J173548-3207) most likely a low-mass X-ray binary in its low state. The distances and corresponding luminosities of the sources in the soft X-ray band (0.5-10 keV) have been estimated; analysis of deep INTEGRAL Galactic center observations has not revealed a statistically significant flux at energies >20 keV from any of them.

  5. Automatic on-line pre-concentration system using a knotted reactor for the FAAS determination of lead in drinking water

    International Nuclear Information System (INIS)

    Souza, Anderson S.; Brandao, Geovani C.; Santos, Walter N.L. dos; Lemos, Valfredo A.; Ganzarolli, Edgard M.; Bruns, Roy E.; Ferreira, Sergio L.C.

    2007-01-01

    An automatic on-line pre-concentration system is proposed for lead determination in drinking water using flame atomic absorption spectrometry (FAAS). Lead(II) ions are retained as the 1-(2-pyridylazo)-2-naphthol (PAN) complex in the walls of a knotted reactor, followed by an elution step using 0.50 mol L -1 hydrochloric acid solution. Optimisation involving the sampling flow rate, pH and buffer concentration factors was performed using a Box-Behnken design. Other factors were established considering results of previous experiments. The procedure allows the determination of lead with a 0.43 μg L -1 detection limit (3σ/S) and precisions (expressed as relative standard deviation) of 4.84% (N = 7) and 2.9% (N = 7) for lead concentrations of 5 and 25 μg L -1 , respectively. The accuracy was confirmed by the determination of lead in the NIST SRM 1643d trace elements in natural water standard reference material. The pre-concentration factor obtained is 26.5 and the sampling frequency is 48 h -1 . The recovery achieved for lead determination in the presence of several ions demonstrated that this procedure could be applied to the analysis of drinking water samples. The method was applied for lead determination in drinking water samples collected in Jequie City, Brazil. The lead concentration found in 25 samples were always lower than the permissible maximum levels stipulated by World Health Organization

  6. Noninvasive Biomonitoring Approaches to Determine Dosimetry and Risk Following Acute Chemical Exposure: Analysis of Lead or Organophosphate Insecticide in Saliva

    International Nuclear Information System (INIS)

    Timchalk, Chuck; Poet, Torka S.; Kousba, Ahmed A.; Campbell, James A.; Lin, Yuehe

    2004-01-01

    There is a need to develop approaches for assessing risk associated with acute exposures to a broad-range of chemical agents and to rapidly determine the potential implications to human health. Non-invasive biomonitoring approaches are being developed using reliable portable analytical systems to quantitate dosimetry utilizing readily obtainable body fluids, such as saliva. Saliva has been used to evaluate a broad range of biomarkers, drugs, and environmental contaminants including heavy metals and pesticides. To advance the application of non-invasive biomonitoring a microfluidic/ electrochemical device has also been developed for the analysis of lead (Pb), using square wave anodic stripping voltammetry. The system demonstrates a linear response over a broad concentration range (1 2000 ppb) and is capable of quantitating saliva Pb in rats orally administered acute doses of Pb-acetate. Appropriate pharmacokinetic analyses have been used to quantitate systemic dosimetry based on determination of saliva Pb concentrations. In addition, saliva has recently been used to quantitate dosimetry following exposure to the organophosphate insecticide chlorpyrifos in a rodent model system by measuring the major metabolite, trichloropyridinol, and saliva cholinesterase inhibition following acute exposures. These results suggest that technology developed for non-invasive biomonitoring can provide a sensitive, and portable analytical tool capable of assessing exposure and risk in real-time. By coupling these non-invasive technologies with pharmacokinetic modeling it is feasible to rapidly quantitate acute exposure to a broad range of chemical agents. In summary, it is envisioned that once fully developed, these monitoring and modeling approaches will be useful for accessing acute exposure and health risk

  7. Determining the bioavailability and toxicity of lead contamination to earthworms requires using a combination of physicochemical and biological methods

    International Nuclear Information System (INIS)

    Luo, Wei; Verweij, Rudo A.; Gestel, Cornelis A.M. van

    2014-01-01

    This study aimed at assessing the bioavailability and toxicity of lead to Eisenia andrei in shooting range soils representing different land uses (forest, grassland, bullet plot). Soils contained 47–2398 mg Pb/kg dry weight (dw), but also had different pH-CaCl 2 (3.2–6.8) and organic matter contents (3.8–13%). Therefore artificial soils with different pH and organic matter contents and two natural soils were included as control soils. Earthworms were exposed for 28 days and toxicity and uptake of Pb were related to total, water and 0.01 M CaCl 2 extractable and porewater Pb concentrations as well as to soil characteristics. Pb uptake in the earthworms linearly increased with increasing soil concentrations. At >2000 mg Pb/kg dw and pH 3.3–3.5, high earthworm mortality with significant weight loss and complete inhibition of reproduction were recorded. At <1000 mg/kg dw, earthworm reproduction was more related to differences in pH and other soil characteristics than to Pb. -- Highlights: • Availability and earthworm toxicity of Pb determined in field-contaminated soils. • Earthworm toxicity of most-polluted soils explained from available Pb levels. • Earthworm response in less polluted soils mainly determined by soil pH. • Earthworm toxicity correlated with Pb uptake from the soil. • Soil properties explained differences in earthworm Pb uptake and effects. -- Combination of physicochemical and biological assays helped explaining Pb toxicity in shooting range soils from available Pb concentrations and soil characteristics

  8. Differential pulse polarography of cadmium-and lead-urate and adsorptive stripping voltammetric determination of uric acid.

    Science.gov (United States)

    Gandour, M A; Ensaf-Aboul-Kasim; Amrallah, A H; Farghaly, O A

    1994-03-01

    The complex formation between uric acid and zinc, cadmium and lead ions has been investigated using differential pulse polarography in 0.01M NaNO(3). It is found that the complexes formed by Cd(II) and Pb(II) ions with uric acid have the stoichiometry of 1:2 and the logarithmic values of the apparent stability constant are 9.47 and 11.7, respectively. On the other hand, zinc(II) ions do not give any indication of complexation with uric acid. A sensitive voltammetric method is developed for the quantitative determination of uric acid. This method is based on controlled adsorptive preconcentration of uric acid on the hanging mercury drop electrode (HMDE), followed by tracing the voltammogram in the cathodic going potential scan. The modes used are direct current stripping voltammetry (DCSV) and differential pulse stripping voltammetry (DPSV). The detection limits found were 8 x 10(-9)M (quiescent period 15 sec) by DPSV and 1.6 x 10(-8)M by DCSV.

  9. Determining soil enzyme activities for the assessment of fungi and citric acid-assisted phytoextraction under cadmium and lead contamination.

    Science.gov (United States)

    Mao, Liang; Tang, Dong; Feng, Haiwei; Gao, Yang; Zhou, Pei; Xu, Lurong; Wang, Lumei

    2015-12-01

    Microorganism or chelate-assisted phytoextraction is an effective remediation tool for heavy metal polluted soil, but investigations into its impact on soil microbial activity are rarely reported. Consequently, cadmium (Cd)- and lead (Pb)-resistant fungi and citric acid (CA) were introduced to enhance phytoextraction by Solanum nigrum L. under varied Cd and Pb pollution levels in a greenhouse pot experiment. We then determined accumulation of Cd and Pb in S. nigrum and the soil enzyme activities of dehydrogenase, phosphatase, urease, catalase, sucrase, and amylase. Detrended canonical correspondence analysis (DCCA) was applied to assess the interactions between remediation strategies and soil enzyme activities. Results indicated that the addition of fungi, CA, or their combination enhanced the root biomass of S. nigrum, especially at the high-pollution level. The combined treatment of CA and fungi enhanced accumulation of Cd about 22-47 % and of Pb about 13-105 % in S. nigrum compared with the phytoextraction alone. However, S. nigrum was not shown to be a hyperaccumulator for Pb. Most enzyme activities were enhanced after remediation. The DCCA ordination graph showed increasing enzyme activity improvement by remediation in the order of phosphatase, amylase, catalase, dehydrogenase, and urease. Responses of soil enzyme activities were similar for both the addition of fungi and that of CA. In summary, results suggest that fungi and CA-assisted phytoextraction is a promising approach to restoring heavy metal polluted soil.

  10. Preconcentration and determination of zinc and lead ions by a combination of cloud point extraction and flame atomic absorption spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Tavallali, H. [Chemistry Department, Payamenore University, Shiraz (Iran); Shokrollahi, A.; Zahedi, M. [Chemistry Department, Yasouj University, Yasouj (Iran); Niknam, K. [Chemistry Department, Persian Gulf University, Bushehr (Iran); Soylak, M. [Chemistry Department, University of Erciyes, Kayseri (Turkey); Ghaedi, M.

    2009-04-15

    The phase-separation phenomenon of non-ionic surfactants occurring in aqueous solution was used for the extraction of lead(II) and zinc(II). After complexation with 3-[(4-bromophenyl) (1-H-inden-3-yl)methyl]-1 H-indene (BPIMI), the analytes were quantitatively extracted to a phase rich in Triton X-114 after centrifugation. Methanol acidified with 1 mol/L HNO{sub 3} was added to the surfactant rich phase prior to its analysis by flame atomic absorption spectrometry (FAAS). The concentration of bis((1H-benzo [d] imidazol-2yl)ethyl)sulfane, Triton X-114, pH and amount of surfactant were all optimized. Detection limits (3 SDb/m) of 2.5 and 1.6 ng/mL for Pb{sup 2+} and Zn{sup 2+} along with preconcentration factors of 30 and an enrichment factor of 32 and 48 for Pb{sup 2+}and Zn {sup 2+} ions were obtained, respectively. The proposed cloud point extraction was been successfully applied for the determination of these ions in real samples with complicated matrices such as food and soil samples, with high efficiency. (Abstract Copyright [2009], Wiley Periodicals, Inc.)

  11. First determination of D* -meson fragmentation functions and their uncertainties at next-to-next-to-leading order

    Science.gov (United States)

    Soleymaninia, Maryam; Khanpour, Hamzeh; Nejad, S. Mohammad Moosavi

    2018-04-01

    We present, for the first time, a set of next-to-next-to-leading order (NNLO) fragmentation functions (FFs) describing the production of charmed-meson D* from partons. Exploiting the universality and scaling violations of FFs, we extract the NLO and NNLO FFs through a global fit to all relevant data sets from single-inclusive e+e- annihilation. The uncertainties for the resulting FFs as well as the corresponding observables are estimated using the Hessian approach. We evaluate the quality of the SKM18 FFs determined in this analysis by comparing with the recent results in literature and show how they describe the available data for single-inclusive D*±-meson production in electron-positron annihilation. As a practical application, we apply the extracted FFs to make our theoretical predictions for the scaled-energy distributions of D*±-mesons inclusively produced in top quark decays. We explore the implications of SKM18 for LHC phenomenology and show that our findings of this study can be introduced as a channel to indirect search for top-quark properties.

  12. Allocation and source attribution of lead and cadmium in maize (Zea mays L.) impacted by smelting emissions

    International Nuclear Information System (INIS)

    Bi Xiangyang; Feng Xinbin; Yang Yuangen; Li Xiangdong; Shin, Grace P.Y.; Li Feili; Qiu Guangle; Li Guanghui; Liu Taoze; Fu Zhiyou

    2009-01-01

    Plants grown in contaminated areas may accumulate trace metals to a toxic level via their roots and/or leaves. In the present study, we investigated the distribution and sources of Pb and Cd in maize plants (Zea mays L.) grown in a typical zinc smelting impacted area of southwestern China. Results showed that the smelting activities caused significantly elevated concentrations of Pb and Cd in the surrounding soils and maize plants. Pb isotope data revealed that the foliar uptake of atmospheric Pb was the dominant pathway for Pb to the leaf and grain tissues of maize, while Pb in the stalk and root tissues was mainly derived from root uptake. The ratio of Pb to Cd concentrations in the plants indicated that Cd had a different behavior from Pb, with most Cd in the maize plants coming from the soil via root uptake. - The sources and pathways of Pb and Cd accumulated in maize were assessed using Pb isotopes and Pb/Cd ratios

  13. Allocation and source attribution of lead and cadmium in maize (Zea mays L.) impacted by smelting emissions

    Energy Technology Data Exchange (ETDEWEB)

    Bi Xiangyang [State Key Laboratory of Environmental Geochemistry, Institute of Geochemistry, Chinese Academy of Sciences, Guiyang 550002 (China); Key Laboratory of Biogeology and Environmental Geology, Ministry of Education, China University of Geosciences, Wuhan 430074 (China); Feng Xinbin [State Key Laboratory of Environmental Geochemistry, Institute of Geochemistry, Chinese Academy of Sciences, Guiyang 550002 (China)], E-mail: fengxinbin@vip.skleg.cn; Yang Yuangen [State Key Laboratory of Environmental Geochemistry, Institute of Geochemistry, Chinese Academy of Sciences, Guiyang 550002 (China); Li Xiangdong; Shin, Grace P.Y. [Department of Civil and Structural Engineering, The Hong Kong Polytechnic University, Hung Hom, Kowloon (Hong Kong); Li Feili [College of Biological and Environmental Engineering, Zhejiang University of Technology, Hangzhou 310032 (China); Qiu Guangle; Li Guanghui; Liu Taoze; Fu Zhiyou [State Key Laboratory of Environmental Geochemistry, Institute of Geochemistry, Chinese Academy of Sciences, Guiyang 550002 (China)

    2009-03-15

    Plants grown in contaminated areas may accumulate trace metals to a toxic level via their roots and/or leaves. In the present study, we investigated the distribution and sources of Pb and Cd in maize plants (Zea mays L.) grown in a typical zinc smelting impacted area of southwestern China. Results showed that the smelting activities caused significantly elevated concentrations of Pb and Cd in the surrounding soils and maize plants. Pb isotope data revealed that the foliar uptake of atmospheric Pb was the dominant pathway for Pb to the leaf and grain tissues of maize, while Pb in the stalk and root tissues was mainly derived from root uptake. The ratio of Pb to Cd concentrations in the plants indicated that Cd had a different behavior from Pb, with most Cd in the maize plants coming from the soil via root uptake. - The sources and pathways of Pb and Cd accumulated in maize were assessed using Pb isotopes and Pb/Cd ratios.

  14. Organic palladium and palladium-magnesium chemical modifiers in direct determination of lead in fractions from distillation of crude oil by electrothermal atomic absorption analysis

    Science.gov (United States)

    Kowalewska, Zofia; Bulska, Ewa; Hulanicki, Adam

    1999-05-01

    Platinum reforming catalysts are easily poisoned by increased levels of lead, therefore a sensitive atomic absorption spectrometric procedure for lead determination in fractions from crude oil distillation was developed. Lead was present in organic form in the samples analysed therefore the behaviour of various lead compounds (Pb-alkylarylsulphonate, Pb-4-cyclohexanobutyrate, tetraethyllead, Pb in fuel oil) was studied. The best procedure for the determination of lead in different petroleum products, including those containing asphaltenes includes a pretreatment with iodine and methyltrioctylammonium chloride, followed by the use of an organic Pd-Mg modifier. Under these conditions an effective matrix removal is possible at a pyrolysis temperature up to approximately 1100°C and the behaviour of lead present in different forms is unified. The characteristic mass is 11-12 pg Pb, corresponding to a detection limit of 0.25 ng g -1 for 20 μl sample solution. This can be lowered by multiple injection.

  15. Recent trends and current practices for secondary processing of zinc and lead. Part II: zinc recovery from secondary sources.

    Science.gov (United States)

    Sahu, Kamala Kanta; Agrawal, Archana; Pandey, Banshi Dhar

    2004-08-01

    Almost all metallurgical processes are associated with the generation of wastes and residues that may be hazardous or non-hazardous in nature depending upon the criteria specified by institutions such as the US Environment Protection Agency, etc. Wastes containing heavy and toxic metals such as arsenic, cadmium, chromium, nickel, lead, copper, mercury, zinc, etc., that are present beyond permissible limits deemed to be treated or disposed of, and non-hazardous wastes can be utilized for metal recovery or safe disposal. Zinc is in growing demand all over the world. In India, a major amount of zinc is imported and therefore processing of zinc secondaries will assist in satisfying the gap between demand and supply to some extent. This report mainly focuses on the current practices and recent trends on the secondary processing of zinc. Attempts made by various laboratories to develop ecofriendly processes for the recovery of zinc from secondary raw materials are also described and discussed.

  16. Using stable lead isotopes to trace heavy metal contamination sources in sediments of Xiangjiang and Lishui Rivers in China.

    Science.gov (United States)

    Sun, Guo-Xin; Wang, Xin-Jun; Hu, Qin-Hong

    2011-12-01

    Lead isotopes and heavy metal concentrations were measured in two sediment cores sampled in estuaries of Xiangjiang and Lishui Rivers in Hunan province, China. The presence of anthropogenic contribution was observed in both sediments, especially in Xiangjiang sediment. In the Xiangjiang sediment, the lower (206)Pb/(207)Pb and higher (208)Pb/(206)Pb ratio, than natural Pb isotope signature (1.198 and 2.075 for (206)Pb/(207)Pb and (208)Pb/(206)Pb, respectively), indicated a significant input of non-indigenous Pb with low (206)Pb/(207)Pb and high (208)Pb/(206)Pb. The corresponding concentrations of heavy metals (As, Cd, Zn, Mn and Pb) were much higher than natural values, suggesting the contaminations of heavy metals from extensive ore-mining activities in the region. Copyright © 2011 Elsevier Ltd. All rights reserved.

  17. Determination of geochemical and anthropogenic uranium sources in soil and tailing

    International Nuclear Information System (INIS)

    Stojanovic, M.; Potpara, D.; Tesmanovic, L.

    2002-01-01

    The origin of uranium in soil (geochemical or anthropogenic) influences the degree of its accessibility to plants. Uranium originating from the geochemical sources is much less, if not quite inaccessible to plants. On the other hand uranium accumulated in soil as a result of anthropogenic activity (use of phosphate fertilisers, dissemination of flying ash from the thermal power plants, dissemination of mining wastes, disposal of nuclear waste and use of ammunition produced from depleted uranium) is most often present in forms much more accessible to plants. The aim of this work was to determine the efficiency of different methods of uranium extraction from soil (used to determine the 'mobile' and accessible contents) which could give the answer on the level of its accessibility to plants, and to determine uranium distribution in various chemical fractions by the method of fractional extraction.The applied method of fractional extraction is based on the idea that all metals form bonds of different strength with the solid phase of soil and such bonds can be completely broken under the effect of reagents such as: 0.1M CaCl 2 (pH - 7.0) for extraction of water-soluble and alternately adsorbed forms of metals; 1M CH 3 COONa (pH - 5.0) for the extraction of specifically adsorbed forms of metals bonded to carbonates; 0.04M hydroxylamine hydrochloride in 25% CH 3 COOH (pH - 3.0) for extraction of metals bonded to Fe and Mn oxide; 0.02M HNO 3 in 30% H 2 O 2 for metals bonded to organic matter. Structurally bonded forms of metals in silicates are determined from the difference of the total uranium content and sum of the metal quantity from the first four fractions. Determination of uranium content in samples was performed by the fluorimetric method. (author)

  18. Air-kerma strength determination of a new directional 103Pd source

    International Nuclear Information System (INIS)

    Aima, Manik; Reed, Joshua L.; DeWerd, Larry A.; Culberson, Wesley S.

    2015-01-01

    Purpose: A new directional 103 Pd planar source array called a CivaSheet™ has been developed by CivaTech Oncology, Inc., for potential use in low-dose-rate (LDR) brachytherapy treatments. The array consists of multiple individual polymer capsules called CivaDots, containing 103 Pd and a gold shield that attenuates the radiation on one side, thus defining a hot and cold side. This novel source requires new methods to establish a source strength metric. The presence of gold material in such close proximity to the active 103 Pd region causes the source spectrum to be significantly different than the energy spectra of seeds normally used in LDR brachytherapy treatments. In this investigation, the authors perform air-kerma strength (S K ) measurements, develop new correction factors for these measurements based on an experimentally verified energy spectrum, and test the robustness of transferring S K to a well-type ionization chamber. Methods: S K measurements were performed with the variable-aperture free-air chamber (VAFAC) at the University of Wisconsin Medical Radiation Research Center. Subsequent measurements were then performed in a well-type ionization chamber. To realize the quantity S K from a directional source with gold material present, new methods and correction factors were considered. Updated correction factors were calculated using the MCNP 6 Monte Carlo code in order to determine S K with the presence of gold fluorescent energy lines. In addition to S K measurements, a low-energy high-purity germanium (HPGe) detector was used to experimentally verify the calculated spectrum, a sodium iodide (NaI) scintillating counter was used to verify the azimuthal and polar anisotropy, and a well-type ionization chamber was used to test the feasibility of disseminating S K values for a directional source within a cylindrically symmetric measurement volume. Results: The UW VAFAC was successfully used to measure the S K of four CivaDots with reproducibilities within

  19. Air-kerma strength determination of a new directional {sup 103}Pd source

    Energy Technology Data Exchange (ETDEWEB)

    Aima, Manik, E-mail: aima@wisc.edu; Reed, Joshua L.; DeWerd, Larry A.; Culberson, Wesley S. [Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin-Madison, Madison, Wisconsin 53705 (United States)

    2015-12-15

    Purpose: A new directional {sup 103}Pd planar source array called a CivaSheet™ has been developed by CivaTech Oncology, Inc., for potential use in low-dose-rate (LDR) brachytherapy treatments. The array consists of multiple individual polymer capsules called CivaDots, containing {sup 103}Pd and a gold shield that attenuates the radiation on one side, thus defining a hot and cold side. This novel source requires new methods to establish a source strength metric. The presence of gold material in such close proximity to the active {sup 103}Pd region causes the source spectrum to be significantly different than the energy spectra of seeds normally used in LDR brachytherapy treatments. In this investigation, the authors perform air-kerma strength (S{sub K}) measurements, develop new correction factors for these measurements based on an experimentally verified energy spectrum, and test the robustness of transferring S{sub K} to a well-type ionization chamber. Methods: S{sub K} measurements were performed with the variable-aperture free-air chamber (VAFAC) at the University of Wisconsin Medical Radiation Research Center. Subsequent measurements were then performed in a well-type ionization chamber. To realize the quantity S{sub K} from a directional source with gold material present, new methods and correction factors were considered. Updated correction factors were calculated using the MCNP 6 Monte Carlo code in order to determine S{sub K} with the presence of gold fluorescent energy lines. In addition to S{sub K} measurements, a low-energy high-purity germanium (HPGe) detector was used to experimentally verify the calculated spectrum, a sodium iodide (NaI) scintillating counter was used to verify the azimuthal and polar anisotropy, and a well-type ionization chamber was used to test the feasibility of disseminating S{sub K} values for a directional source within a cylindrically symmetric measurement volume. Results: The UW VAFAC was successfully used to measure the S

  20. Determinants of the accuracy of nursing diagnoses: influence of ready knowledge, knowledge sources, disposition toward critical thinking, and reasoning skills.

    Science.gov (United States)

    Paans, Wolter; Sermeus, Walter; Nieweg, Roos; van der Schans, Cees

    2010-01-01

    The purpose of this study was to determine how knowledge sources, ready knowledge, and disposition toward critical thinking and reasoning skills influence the accuracy of student nurses' diagnoses. A randomized controlled trial was conducted to determine the influence of knowledge sources. We used the following questionnaires: (a) knowledge inventory, (b) California Critical Thinking Disposition Inventory, and (c) Health Science Reasoning Test (HSRT). The use of knowledge sources had very little influence on the accuracy of nursing diagnoses. Accuracy was significantly related to the analysis domain of the HSRT. Students were unable to operationalize knowledge sources to derive accurate diagnoses and did not effectively use reasoning skills. Copyright 2010 Elsevier Inc. All rights reserved.

  1. Determination of the reference air kerma rate for 192Ir brachytherapy sources and the related uncertainty

    International Nuclear Information System (INIS)

    Dijk, Eduard van; Kolkman-Deurloo, Inger-Karine K.; Damen, Patricia M. G.

    2004-01-01

    Different methods exist to determine the air kerma calibration factor of an ionization chamber for the spectrum of a 192 Ir high-dose-rate (HDR) or pulsed-dose-rate (PDR) source. An analysis of two methods to obtain such a calibration factor was performed: (i) the method recommended by [Goetsch et al., Med. Phys. 18, 462-467 (1991)] and (ii) the method employed by the Dutch national standards institute NMi [Petersen et al., Report S-EI-94.01 (NMi, Delft, The Netherlands, 1994)]. This analysis showed a systematic difference on the order of 1% in the determination of the strength of 192 Ir HDR and PDR sources depending on the method used for determining the air kerma calibration factor. The definitive significance of the difference between these methods can only be addressed after performing an accurate analysis of the associated uncertainties. For an NE 2561 (or equivalent) ionization chamber and an in-air jig, a typical uncertainty budget of 0.94% was found with the NMi method. The largest contribution in the type-B uncertainty is the uncertainty in the air kerma calibration factor for isotope i, N k i , as determined by the primary or secondary standards laboratories. This uncertainty is dominated by the uncertainties in the physical constants for the average mass-energy absorption coefficient ratio and the stopping power ratios. This means that it is not foreseeable that the standards laboratories can decrease the uncertainty in the air kerma calibration factors for ionization chambers in the short term. When the results of the determination of the 192 Ir reference air kerma rates in, e.g., different institutes are compared, the uncertainties in the physical constants are the same. To compare the applied techniques, the ratio of the results can be judged by leaving out the uncertainties due to these physical constants. In that case an uncertainty budget of 0.40% (coverage factor=2) should be taken into account. Due to the differences in approach between the

  2. The determination of major and some minor constituents in lead zirconate-titanate compositions by x-ray fluorescence and atomic absorption spectrometry

    NARCIS (Netherlands)

    van Willigen, J.H.H.G.; Kruidhof, H.; Dahmen, E.A.M.F.

    1972-01-01

    An accurate X-ray fluorescence spectrometric method is described for the determination of lead, zirconium and titanium in lead zirconate-titanate ceramics. Careful matching of samples and standards by a borax fusion method resulted in a relative standard deviation of about 0.2% for the major

  3. Determination, source identification and GIS mapping for nitrate concentration in ground water from Bara aquifer

    International Nuclear Information System (INIS)

    Elfaki Taha, G. M. E.

    2010-09-01

    The study was carried-out determine the level of nitrate concentration in well water from Bara aquifer in North Kordofan State. The analysis was conducted for 69 wells from different villages within Bara basin. Physical characteristics were measured including pH, electrical conductivity and dissolved oxygen. Spectrophotometric analysis was used to determine nitrate, nitrite and ammonia. Chloride and hardness were determined telemetrically and flame photometer was used for major elements namely sodium and potassium, whereas atomic absorption spectroscopy was used for trace elements namely iron, manganese, zinc and copper. Results revealed that nitrate concentration range from 9.68 to 891 mg/1 in sampled wells with 81% exceeding the maximum permissible limits set for drinking water by WHO and SSMO. Animal waste and organic soil nitrogen were found to be the sources of nitrate in these wells as indicated by 15 N%. Majority of wells with high nitrate are located in the north and the north-east part of the study area as shown by GIS predictive map. On the average, the concentrations of sodium, potassium, calcium, magnesium, iron, manganese, zinc and copper were found to be within WHO limits for drinking water. (Author)

  4. Optic axis determination by fibre-based polarization-sensitive swept-source optical coherence tomography

    Energy Technology Data Exchange (ETDEWEB)

    Lu Zenghai; Kasaragod, Deepa K; Matcher, Stephen J, E-mail: z.lu@sheffield.ac.uk, E-mail: s.j.matcher@sheffield.ac.uk [Department of Materials Science and Engineering, Kroto Research Institute, University of Sheffield, North Campus, Broad Lane, Sheffield, S3 7HQ (United Kingdom)

    2011-02-21

    We describe a fibre-based variable-incidence angle (VIA) polarization-sensitive swept-source optical coherence tomography (PS-SS-OCT) system to determine the 3D optical axis of birefringent biological tissues. Single-plane VIA-PS-OCT is also explored which requires measurement of the absolute fast-axis orientation. A state-of-the-art PS-SS-OCT system with some improvements both in hardware and software was used to determine the apparent optical birefringence of equine tendon for a number of different illumination directions. Polar and azimuthal angles of cut equine tendon were produced by the VIA method and compared with the nominal values. A quarter waveplate (QWP) and equine tendon were used as test targets to validate the fast-axis measurements using the system. Polar and azimuthal angles of cut equine tendon broadly agreed with the expected values within about 8% of the nominal values. A theoretical and experimental analysis of the effect of the sample arm fibre on determination of optical axis orientation using a proposed definition based on the orientation of the eigenpolarization ellipse experimentally confirms that this algorithm only works correctly for special settings of the sample arm fibre. A proposed algorithm based on the angle between Stokes vectors on the Poincare sphere is confirmed to work for all settings of the sample arm fibre. A calibration procedure is proposed to remove the sign ambiguity of the measured orientation and was confirmed experimentally by using the QWP.

  5. Optic axis determination by fibre-based polarization-sensitive swept-source optical coherence tomography

    International Nuclear Information System (INIS)

    Lu Zenghai; Kasaragod, Deepa K; Matcher, Stephen J

    2011-01-01

    We describe a fibre-based variable-incidence angle (VIA) polarization-sensitive swept-source optical coherence tomography (PS-SS-OCT) system to determine the 3D optical axis of birefringent biological tissues. Single-plane VIA-PS-OCT is also explored which requires measurement of the absolute fast-axis orientation. A