WorldWideScience

Sample records for determining lead sources

  1. The identification of lead ammunition as a source of lead exposure in First Nations: The use of lead isotope ratios

    International Nuclear Information System (INIS)

    Tsuji, Leonard J.S.; Wainman, Bruce C.; Martin, Ian D.; Sutherland, Celine; Weber, Jean-Philippe; Dumas, Pierre; Nieboer, Evert

    2008-01-01

    The use of lead shotshell to hunt water birds has been associated with lead-contamination in game meat. However, evidence illustrating that lead shotshell is a source of lead exposure in subsistence hunting groups cannot be deemed definitive. This study seeks to determine whether lead shotshell constitutes a source of lead exposure using lead isotope ratios. We examined stable lead isotope ratios for lichens, lead shotshell and bullets, and blood from residents of Fort Albany and Kashechewan First Nations, and the City of Hamilton, Ontario, Canada. Data were analyzed using ANOVA and regression analyses. ANOVA of isotope ratios for blood revealed significant differences with respect to location, but not sex. Hamilton differed from both Kashechewan and Fort Albany; however, the First Nations did not differ from each other. ANOVA of the isotope ratios for lead ammunition and lichens revealed no significant differences between lichen groups (north and south) and for the lead ammunition sources (pellets and bullets). A plot of 206 Pb/ 204 Pb and 206 Pb/ 207 Pb values illustrated that lichens and lead ammunition were distinct groupings and only the 95% confidence ellipse of the First Nations group overlapped that of lead ammunition. In addition, partial correlations between blood-lead levels (adjusted for age) and isotope ratios revealed significant (p 206 Pb/ 204 Pb and 206 Pb/ 207 Pb, and a significant negative correlation for 208 Pb/ 206 Pb, as predicted if leaded ammunition were the source of lead exposure. In conclusion, lead ammunition was identified as a source of lead exposure for First Nations people; however, the isotope ratios for lead shotshell pellets and bullets were indistinguishable. Thus, lead-contaminated meat from game harvested with lead bullets may also be contributing to the lead body burden

  2. Identification of sources of lead exposure in French children by lead isotope analysis: a cross-sectional study

    Directory of Open Access Journals (Sweden)

    Lucas Jean-Paul

    2011-08-01

    Full Text Available Abstract Background The amount of lead in the environment has decreased significantly in recent years, and so did exposure. However, there is no known safe exposure level and, therefore, the exposure of children to lead, although low, remains a major public health issue. With the lower levels of exposure, it is becoming more difficult to identify lead sources and new approaches may be required for preventive action. This study assessed the usefulness of lead isotope ratios for identifying sources of lead using data from a nationwide sample of French children aged from six months to six years with blood lead levels ≥25 μg/L. Methods Blood samples were taken from 125 children, representing about 600,000 French children; environmental samples were taken from their homes and personal information was collected. Lead isotope ratios were determined using quadrupole ICP-MS (inductively coupled plasma - mass spectrometry and the isotopic signatures of potential sources of exposure were matched with those of blood in order to identify the most likely sources. Results In addition to the interpretation of lead concentrations, lead isotope ratios were potentially of use for 57% of children aged from six months to six years with blood lead level ≥ 25 μg/L (7% of overall children in France, about 332,000 children, with at least one potential source of lead and sufficiently well discriminated lead isotope ratios. Lead isotope ratios revealed a single suspected source of exposure for 32% of the subjects and were able to eliminate at least one unlikely source of exposure for 30% of the children. Conclusions In France, lead isotope ratios could provide valuable additional information in about a third of routine environmental investigations.

  3. Lead isotopes as an environmental indicator of pollution sources

    International Nuclear Information System (INIS)

    Aaberg, G.; Pacyna, J.; Stray, H.

    1997-02-01

    An interesting question when determining and quantifying pollution is the characterisation of the sources. Also, is the pollution locally derived or is it longtransported? Analyses of Pb isotope ratios and Pb concentrations on airfilter from Oslo, Norway, together with analyses of coal of different origin and wood, show that the decrease in total Pb in the first half of the 1990's is not due only to the reduction of leaded petrol but that there are other important sources for the pollution which have been cut down. The reduction in emissions from coal burning in Europe can be seen on airfilter from Oslo and also the following reduction in leaded petrol. An isotopic study of lead on airfilter from the countryside outside Oslo implies that the finer particles have been atmospherically long transported while the coarser particles are of a more local origin, e.g. from domestic burning of wood. The above results show that the use of a natural isotopic system like Pb is a powerful tool for e.g. the determination of pollution, routes of its transportation, for the monitoring of processes of the present, and for provenance determinations. 7 refs., 8 figs., 2 tabs

  4. Determination of lead isotopic composition of airborne particulate matter by ICPMS: implications for lead atmospheric emissions in Canada

    International Nuclear Information System (INIS)

    Celo, V.; Dabek-Zlotorzynska, E.

    2009-01-01

    Full text: Quadrupole ICPMS was used for determination of trace metal concentrations and lead isotopic composition in fine particulate matter (PM 2.5 ) collected at selected sites within the Canadian National Air Pollution Surveillance network, from February 2005 to February 2007. High enrichment factors indicated that lead is mostly of anthropogenic origin and consequently, the lead isotopic composition is directly related to that of pollution sources. The 206 Pb/ 207 Pb and 208 Pb/ 207 Pb ratios were measured and the results were compared to the isotopic signatures of lead from different sources. Various approaches were used to assess the impact of relevant sources and the meteorological conditions in the occurrence and distribution of lead in Canadian atmospheric aerosols. (author)

  5. Determining tissue-lead levels in large game mammals harvested with lead bullets: human health concerns.

    Science.gov (United States)

    Tsuji, L J S; Wainman, B C; Jayasinghe, R K; VanSpronsen, E P; Liberda, E N

    2009-04-01

    Recently, the use of lead isotope ratios has definitively identified lead ammunition as a source of lead exposure for First Nations people, but the isotope ratios for lead pellets and bullets were indistinguishable. Thus, lead-contaminated meat from game harvested with lead bullets may also be contributing to the lead body burden; however, few studies have determined if lead bullet fragments are present in big game carcasses. We found elevated tissue-lead concentrations (up to 5,726.0 microg/g ww) in liver (5/9) and muscle (6/7) samples of big game harvested with lead bullets and radiographic evidence of lead fragments. Thus, we would advise that the tissue surrounding the wound channel be removed and discarded, as this tissue may be contaminated by lead bullet fragments.

  6. Historical record of lead accumulation and source in the tidal flat of Haizhou Bay, Yellow Sea: Insights from lead isotopes

    International Nuclear Information System (INIS)

    Zhang, Rui; Guan, Minglei; Shu, Yujie; Shen, Liya; Chen, Xixi; Zhang, Fan; Li, Tiegang

    2016-01-01

    In order to investigate the historical records of lead contamination and source in coastal region of Haizhou Bay, Yellow Sea, a sediment core was collected from tidal flat, dated by 210 Pb and 137 Cs. Lead and its stable isotopic ratios were determined. The profiles of enrichment factor (EF) and Pb isotope ratios showed increasing trend upward throughout the core, correlating closely with the experience of a rapid economic and industrial development of the catchment. According to Pb isotopic ratios, coal combustion emission mainly contributed to the Pb burden in sediments. Based on end-member model, coal combustion emission dominated anthropogenic Pb sources in recent decades contributing from 48% to 67% in sediment. And the contribution of leaded gasoline was lower than 20%. A stable increase of coal combustion source was found in sediment core, while the contribution of leaded gasoline had declined recently, with the phase-out of leaded gasoline in China. - Highlights: •Pb contamination in tidal flat of Haizhou Bay was chronicled by a sediment core. •The coal combustion source dominated Pb contamination of Haizhou Bay. •Coal combustion source showed an increasing trend in four decades in Haizhou Bay.

  7. Levels and source apportionment of children's lead exposure: Could urinary lead be used to identify the levels and sources of children's lead pollution?

    International Nuclear Information System (INIS)

    Cao, Suzhen; Duan, Xiaoli; Zhao, Xiuge; Wang, Beibei; Ma, Jin; Fan, Delong; Sun, Chengye; He, Bin; Wei, Fusheng; Jiang, Guibin

    2015-01-01

    As a highly toxic heavy metal, the pollution and exposure risks of lead are of widespread concern for human health. However, the collection of blood samples for use as an indicator of lead pollution is not always feasible in most cohort or longitudinal studies, especially those involving children health. To evaluate the potential use of urinary lead as an indicator of exposure levels and source apportionment, accompanying with environmental media samples, lead concentrations and isotopic measurements (expressed as 207 Pb/ 206 Pb, 208 Pb/ 206 Pb and 204 Pb/ 206 Pb) were investigated and compared between blood and urine from children living in the vicinities of a typical coking plant and lead-acid battery factory. The results showed urinary lead might not be a preferable proxy for estimating blood lead levels. Fortunately, urinary lead isotopic measurements could be used as an alternative for identifying the sources of children's lead exposure, which coincided well with the blood lead isotope ratio analysis. - Highlights: • Pb isotopes of environmental media and children's blood and urine were analyzed. • Pb exposure and pollution source were studied in lead-acid battery and coking areas. • Pb isotope ratios in blood and urine were similar to those of food, water and PM. • Urine Pb level may not be used as a proxy for indicating the lead levels in blood. • Urine Pb isotope ratios is an alternative to identify source and exposure pathways. - Urinary lead is not a preferable proxy to estimate blood lead level, but urinary lead isotope ratios could be an alternative for identifying the sources of lead exposure in children

  8. Levels and source apportionment of children's lead exposure: could urinary lead be used to identify the levels and sources of children's lead pollution?

    Science.gov (United States)

    Cao, Suzhen; Duan, Xiaoli; Zhao, Xiuge; Wang, Beibei; Ma, Jin; Fan, Delong; Sun, Chengye; He, Bin; Wei, Fusheng; Jiang, Guibin

    2015-04-01

    As a highly toxic heavy metal, the pollution and exposure risks of lead are of widespread concern for human health. However, the collection of blood samples for use as an indicator of lead pollution is not always feasible in most cohort or longitudinal studies, especially those involving children health. To evaluate the potential use of urinary lead as an indicator of exposure levels and source apportionment, accompanying with environmental media samples, lead concentrations and isotopic measurements (expressed as (207)Pb/(206)Pb, (208)Pb/(206)Pb and (204)Pb/(206)Pb) were investigated and compared between blood and urine from children living in the vicinities of a typical coking plant and lead-acid battery factory. The results showed urinary lead might not be a preferable proxy for estimating blood lead levels. Fortunately, urinary lead isotopic measurements could be used as an alternative for identifying the sources of children's lead exposure, which coincided well with the blood lead isotope ratio analysis. Copyright © 2015 Elsevier Ltd. All rights reserved.

  9. Lead shot from hunting as a source of lead in human blood

    International Nuclear Information System (INIS)

    Johansen, Poul; Pedersen, Henning Sloth; Asmund, Gert; Riget, Frank

    2006-01-01

    This study investigates the relationship between the intake of birds hunted with lead shot and the lead concentration in human blood. Fifty adult men from Nuuk, Greenland took part in the study. From September 2003 to June 2004 they regularly gave blood samples and recorded how many birds they ate. We found a clear relationship between the number of bird meals and blood lead and also a clear seasonal variation. The concentration was highest in mid-winter when bird consumption is at its highest. Blood lead was low (15 μg/L, mean concentration) among the participants reporting not eating birds. Among those reporting to eat birds regularly, blood lead was significantly higher, up to 128 μg/L (mean concentration). Concentrations depended on the frequency of bird meals: the more the bird meals, the higher the resulting blood lead. This clear relationship points to lead shot as the dominating lead source to people in Greenland. - Birds hunted with lead shot and consumed are a source of lead in human blood

  10. Lead shot from hunting as a source of lead in human blood

    Energy Technology Data Exchange (ETDEWEB)

    Johansen, Poul [National Environmental Research Institute, Frederiksborgvej 399, DK-4000 Roskilde (Denmark)]. E-mail: poj@dmu.dk; Pedersen, Henning Sloth [Primary Health Care Center, DK-3900 Nuuk (Greenland); Asmund, Gert [National Environmental Research Institute, Frederiksborgvej 399, DK-4000 Roskilde (Denmark); Riget, Frank [National Environmental Research Institute, Frederiksborgvej 399, DK-4000 Roskilde (Denmark)

    2006-07-15

    This study investigates the relationship between the intake of birds hunted with lead shot and the lead concentration in human blood. Fifty adult men from Nuuk, Greenland took part in the study. From September 2003 to June 2004 they regularly gave blood samples and recorded how many birds they ate. We found a clear relationship between the number of bird meals and blood lead and also a clear seasonal variation. The concentration was highest in mid-winter when bird consumption is at its highest. Blood lead was low (15 {mu}g/L, mean concentration) among the participants reporting not eating birds. Among those reporting to eat birds regularly, blood lead was significantly higher, up to 128 {mu}g/L (mean concentration). Concentrations depended on the frequency of bird meals: the more the bird meals, the higher the resulting blood lead. This clear relationship points to lead shot as the dominating lead source to people in Greenland. - Birds hunted with lead shot and consumed are a source of lead in human blood.

  11. Lead isotopes reveal different sources of lead in balsamic and other vinegars

    International Nuclear Information System (INIS)

    Ndung'u, Kuria; Hibdon, Sharon; Veron, Alain; Flegal, A. Russell

    2011-01-01

    Fifty-eight brands of balsamic vinegars were analyzed for lead concentrations and isotopic compositions ( 204 Pb, 206 Pb, 207 Pb, and 208 Pb) to test the findings of a previous study indicating relatively high levels of lead contamination in some of those vinegars - more than two thirds (70%) of them exceeded California's State Maximum Level (34 μg/L) based on consumption rates ≥ 0.5 μg Pb per day. The Lead isotopic fingerprints of all those vinegars with high lead concentrations were then found to be primarily anthropogenic. This isotopic analysis unquestionably reveals multiple contamination sources including atmospheric pollutant Pb and an unidentified contamination source, likely occurring after grape harvest. Organically grown grape vinegars display the same Pb content and isotopic signatures as other vinegars. This implies that pesticides might not be a significant source of pollutant Pb in vinegars. A significant post-harvest contamination would be inherited from chemicals added during production and/or material used during transport, processing or storage of these vinegars. This is consistent with the highest Pb levels being found in aged vinegars (112 ± 112 μg/L) in contrast to other vinegars (41.6 ± 28.9 μg/L) suggesting contamination during storage. It is, therefore, projected that lead levels in most vinegars, especially aged balsamic and wine vinegars, will decrease with improvements in their manufacture and storage processes consequential to recent concerns of elevated levels of lead in some vinegars. - Highlights: → First extensive study on content and possible sources of lead in balsamic vinegars. → Half of the vinegars exceed California's State Maximum Level for human consumption. → Lead content in vinegars seems to be mainly post-harvest from industrial processes.

  12. Determination of lead 210 atmospheric fluxes in Syria

    International Nuclear Information System (INIS)

    Al-Masri, M. S.; Shaik Khalil, H.

    2001-01-01

    Lead 210 atmospheric fluxes were determined by collecting 51 profiles from Syrian soil during 1998. Lead 210 fluxes in Syria calculated from lead 210 inventory in soil ranged from 15 Bq.m -2 .y -1 and 407 Bq.m -2 .y -1 with an average value of 128 Bq.m -2 .y -1 . the highest fluxes were found to be in Hama area due to the Gaab fault, which is considered as a radon source in the area. In addition, fluxes were also high in most sites, which are located in Syria valleys and around the lakes. Moreover, the study has indicated that there is no linear relation between lead 210 flux values and other parameters such as annual rainfall and bulk density of the soil. On the other hand, an effect, of those two factors on lead 210 distribution with depth has been observed. In addition, the results of variable lead 210 fluxes from site to another have proved that it is necessary, in order to obtain a representative mean value of lead 210 flux obtained in this study is within the worldwide range for lead 210 flux. (Author)

  13. Isotope ratios of lead as pollutant source indicators

    International Nuclear Information System (INIS)

    Chow, T.J.; Snyder, C.B.; Earal, J.L.

    1975-01-01

    Each lead ore deposit has its characteristic isotope ratios which are fixed during mineral ore genesis, and this unique property can be used to indicate the source of lead pollutants in the environment. The wolld production of primary lead is tabulated, and the geochemical significances of lead isotope ratios are discussed. The manufacture of lead alkyl additives for gasoline, which is the major source of lead pollutants, utilizes about 10% of the world annual consumption of lead. The isotope ratios of lead in gasoline, aerosols, soils and plants are correlated. Lead additives in various brands of gasoline sold in one region do not have the same isotope ratios. Regional variations in isotope ratios of lead additives were observed. This reflects the fact that petroleum refineries obtained the additives from various lead alkyl manufacturers which utilized lead from different mining districts. A definite changing trend of isotope ratios of lead pollutants in the San Diego, California (USA), area was detected. The lead shows a gradual increase in its radiogenic components during the past decade. This trend can be explained by the change of lead sources used by the additive manufacturers: Lead isotope ratios of the mid-1960's gasoline additives in the United States of America reflected those of less radiogenic leads imported from Canada, Australia, Peru and Mexico. Since then, the U.S. lead production has doubled-mainly from the Missouri district of highly radiogenic lead. Meanwhile, there has been a decrease in total lead imports. These combined effects result in changes in isotope ratios, from the less to more radiogenic, of the pooled lead. (aothor)

  14. Determination of lead in rice grains by solid sampling HR-CS GFAAS.

    Science.gov (United States)

    Gunduz, Sema; Akman, Suleyman

    2013-12-01

    A study was performed for the determination of lead in rice grains directly by solid sampling high resolution continuum source graphite furnace atomic absorption spectrometry (HR-CS GFAAS) without digesting sample. The effects of sample amount, pyrolysis/atomization temperatures on the determination of lead in rice were investigated and optimized using a certificated rice flour. The lead concentrations were determined applying 800 °C of pyrolysis and 1800 °C of atomization temperatures without modifier. LOD (N=10, 3σ) and characteristic mass were 2.3 μg kg(-1) and 8.1 pg, respectively. The certified lead value of a rice flour CRM was found in its uncertainity limits. The lead contents of various rice samples obtained from markets in Turkey were between 0.009 and 0.162 mg kg(-1) which are in acceptable range. The average lead concentrations in various rice grains taken from the same package were significantly different from each other. Copyright © 2013 Elsevier Ltd. All rights reserved.

  15. Characterization of sources of lead in the urban air of Asia using ratios of stable lead isotopes

    Energy Technology Data Exchange (ETDEWEB)

    Mukai, H.; Furuta, N.; Fujii, T.; Ambe, Y.; Sakamoto, K.; Hashimoto, Y. (National Institute of Environmental Studies, Tsukuba (Japan). Environmental Chemistry Division)

    1993-07-01

    Airborne particulate matter was collected at urban sites in six Asian countries (Japan, South Korea, China, Thailand, Sri Lanka, and Indonesia), and the stable lead isotope ratios were measured. Some source-related materials, such as coal and leaded gasoline, were also analyzed and compared to the ratios observed in airborne lead. Airborne lead isotope ratios differed considerably from each other, and these differences corresponded to differences in the regional source of lead. Leaded gasoline was still the primary source of lead in some cities in Asia, and the lead isotope ratios were strongly influenced by those of leaded gasoline. In Chinese and Korean cities, however, the considerable effect from coal combustion and industrial activity was also observed in their isotope ratios, despite leaded gasoline use. On the other hand, only refuse incineration was a possible single source of lead in Japanese air from the view of lead isotope ratios. 49 refs., 13 figs., 3 tabs.

  16. Sensitivity of in vivo X-ray fluorescence determination of skeletal lead stores

    International Nuclear Information System (INIS)

    Sokas, R.K.; Besarab, A.; McDiarmid, M.A.; Shapiro, I.M.; Bloch, P.

    1990-01-01

    Eighteen patients with known past occupational lead exposure underwent parenteral diagnostic chelation with ethylenediaminetetraacetic acid and x-ray fluorescent determination of in vivo skeletal lead stores at the distal styloid process of the ulna and at the temporal base bone using a cobalt 57 source and measuring lead Ka x-rays. X-ray fluorescent lead measurements in both locations correlated with results of diagnostic chelation. Using a post-chelation urinary excretion of greater than 600 micrograms lead/24 h as the definition of high-lead stores, sensitivity of x-ray fluorescence at the wrist and temple was 56% and 39%, respectively

  17. Lead pollution sources and Impacts

    International Nuclear Information System (INIS)

    El-Haggar, S.M.; Saad, S.G.; Saleh, S.K.; El-Kady, M.A.

    1996-01-01

    Despite the medical awareness of lead toxicity, and despite legislation designed to reduce environmental contamination, lead is one of the most widely used heavy metals. Significant human exposure occurs from automobile exhaust fumes, cigarette smoking, lead-based paints and plumbing systems lead spread in the environment can take place in several ways, the most important of which is through the lead compounds released in automobile exhaust as a direct result of the addition of tetraethyl or tetraethyl lead to gasoline as octane boosting agents. Of special is the effect of lead pollution on children, which affects their behavioral and educational attributes considerably. The major channel through through which lead is absorbed is through inhalation of lead compounds in the atmosphere. Lead is a heavy metal characterized its malleability, ductility and poor conduction of electricity. So, it has a wide range of applications ranging from battery manufacturing to glazing ceramics. It is rarely found free in nature but is present in several minerals and compounds. The aim of this paper is to discuss natural and anthropogenic sources of lead together with its distribution and trends with emphasis on egypt. The effects of lead pollution on human health, vegetation and welfare are also presented. It could be concluded that, the excessive release of lead into the environment, especially through the atmosphere, can produce many detrimental and sometimes fatal effects on human, agriculture and zoological life. Besides, it is very plain that there is a serious problem of pollution lead in egypt and specially in cairo. 7 figs

  18. Lead isotope identification of sources of galena from some prehistoric Indian sites in Ontario, Canada

    International Nuclear Information System (INIS)

    Farquhar, R.M.; Fletcher, I.R.

    1980-01-01

    Lead isotopic compositions of 12 galenas from five late Archaic-initial Woodland grave and habitation sites in southern Ontario have made it possible to determine the most likely source areas for the galenas. For one of the oldest sites (Finlan), the most likely source is in the southwestern Upper Mississippi Valley (Wisconsin-Illinois-Iowa) mineral district. The seven Finlan galenas exhibit a range of isotopic ratios; three of the largest specimens have substantial isotopic variations (up to 1.8% in the ratio of lead-207 to lead-206) on a scale of a few centimeters. This suggests that the lead isotopic zoning ascribed to the Upper Mississippi Valley area is not sufficiently well defined to enable us to determine if all the Finlan samples were derived from a single mineral deposit. Galenas from the other sites (Constance Bay, Hind, Bruce Boyd, and Picton) most probably originated in the southeastern Ontario-northwestern New York area. Isotopic differences among the Constance Bay, Hind, and Bruce Boyd galenas, on the one hand, and the Picton galena, on the other, suggest that at least two distinct sources in that region were exploited

  19. The isotopic composition of lead in man and the environment in Finland: isotope ratios of lead as indicators of pollutant source

    International Nuclear Information System (INIS)

    Keinonen, M.

    1989-01-01

    The isotopic composition of lead was determined in samples from the Helsinki area: in emission sources (gasoline, incinerator and lead smelter emissions, coal), in sources of intake to man (air, diet), in samples representing long-term deposition (lichen, soil, lake sediments) and in human tissue. The measurements of the isotope ratios 206 Pb/ 204 Pb and 206 Pb/ 207 Pb were done by thermal ionization mass spectrometry after chemical separation of lead by anion exchange and cathodic electrodeposition. The origin of lead in man and the environment in the Helsinki area was evaluated by using the differences in the measured isotope ratios as an indicator. The means of the ratios in gasoline ( 206 Pb/ 207 Pb 1.124+-0.026, 206 Pb/ 204 Pb 17.45+-0.42) and the ratios in other emission sources in Helsinki ( 206 Pb/ 207 Pb 1.149-1.226, 206 Pb/ 204 Pb 17.94-19.24) were significantly different. Lead in air samples from Helsinki (1.123+-0.013) could be attributed to gasoline, as lead in soil near a highway (1.136+-0.003). By contrast, isotope ratios measured in lichen (1.148+-0.006) indicated considerable amounts of lead from sources with higher 206 Pb abundances, evidently industrial sources. The isotope ratios in human liver, lung, and bone ( 206 Pb/ 207 Pb 1.142+-0.015, 1.151+-0.011, and 1.156+-0.013, respectively and 206 Pb/ 204 Pb 17.76+-0.28, 17.91+-0.20, and 17.96+-0.09, respectively) were practically the same and no significant dependence of the isotope ratios on age or concentration of lead was seen. In lake sediment cores a correlation was found between the isotope ratios, lead concentration, and depth. The non-anthropogenic lead of high isotope ratios from bedrock was the major component at depths dated older than 100 years. At the surface of the sediment atmospheric lead prevailed, with ratios similar to those of gasoline, air samples and lichen. In the post-1900 layers, anthropogenic lead made up about 40-60% of the total sedimentary lead

  20. Studies in the determination of lead isotope ratios by inductively coupled plasma mass spectrometry

    International Nuclear Information System (INIS)

    Date, A.R.; Yuk Ying Cheung

    1987-01-01

    The application of ICP-MS to the determination of lead isotope ratios in geological materials is described. Data presented for a series of lead mineral concentrates are compared with reference values obtained by conventional solid source thermal ionisation mass spectrometry. The simultaneous determination of lead isotope ratios and trace elements is carried out in a rapid analysis mode. The application of an electrothermal vaporisation technique for small solution aliquots is described. Lead isotope ratio data for the United States Geological Survey standard reference silicate rock BCR-1, obtained without separation of lead from the matrix, are compared with previously published values obtained after separation. (author)

  1. Drinking water: a major source of lead exposure in Karachi, Pakistan.

    Science.gov (United States)

    Ul-Haq, N; Arain, M A; Badar, N; Rasheed, M; Haque, Z

    2011-11-01

    Excess lead in drinking water is a neglected source of lead toxicity in Pakistan. A cross-sectional survey in 2007/08 was made of water samples from drinking water sources in Karachi, a large industrial city. This study aimed to compare lead levels between untreated ground water and treated surface (tap) water in 18 different districts. Of 216 ground and surface water samples collected, 86% had lead levels higher than the World Health Organization maximum acceptable concentration of l0 ppb. Mean lead concentration in ground water [146 (SD 119) ppb] was significantly higher than in surface water [77.1 (SD 54) ppb]. None of the 18 districts had a mean lead level of ground or surface water below the WHO cut-off and ground water sources in 9 districts had a severe level of contamination (>150 ppb). Urgent action is needed to eliminate sources of contamination.

  2. Lead sources in human diet in Greenland

    DEFF Research Database (Denmark)

    Bjerregaard, Peter; Johansen, Poul; Mulvad, Gert

    2004-01-01

    Although blood lead levels have declined in Greenland, they are still elevated despite the fact that lead levels in the Greenland environment are very low. Fragments of lead shot in game birds have been suggested as an important source of dietary exposure, and meals of sea birds, particularly eider......, contain high concentrations of lead. In a cross-sectional population survey in Greenland in 1993-1994, blood lead adjusted for age and sex was found to be associated with the reported consumption of sea birds. Participants reporting less than weekly intake of sea birds had blood lead concentrations...... of approximately 75 microg/L, whereas those who reported eating sea birds several times a week had concentrations of approximately 110 microg/L, and those who reported daily intake had concentrations of 170 microg/L (p = 0.01). Blood lead was not associated with dietary exposure to other local or imported food...

  3. Surma eye cosmetic in Afghanistan: a potential source of lead toxicity in children.

    Science.gov (United States)

    McMichael, J R; Stoff, B K

    2018-02-01

    Surma is a traditional eye cosmetic used as an eyeliner for infants in Afghanistan, as well as in many other countries in Asia, the Middle East, and Africa. Surma has been reported to contain lead and to be a potential source of lead toxicity in children, which can lead to permanent damage to multiple organ systems. To our knowledge, assessment for lead in surma found in Afghanistan has not been performed. We determined the quantitative lead content of a convenience sample of 10 surma products acquired in Afghanistan. Analysis revealed that 70% of surma samples contained high levels of lead (range 35-83%). The remaining samples contained low levels of lead (range 0.04-0.17%). The majority of surma samples contained very high levels of lead, a troubling finding that could potentially correlate with lead toxicity in Afghan children. Making available lead-free surma alternatives and providing health education, for both healthcare professionals and the general population, in locations where surma use is prevalent and for those involved in care of refugees and immigrants from Afghanistan, may be strategies to prevent lead poisoning in children. What is Known: • Surma is a traditional cosmetic used as an eyeliner for infants in Afghanistan as well as in many countries in Asia, the Middle East, and Africa. • Surma has been reported to contain lead and to be a source of lead toxicity in children. What is New: • Assessment for lead content in surma found in Afghanistan has not been performed. • In this convenience sample of 10 surma products acquired in Afghanistan, 70% contained very high levels of lead.

  4. Investigation of spectral interferences in the determination of lead in fertilizers and limestone samples using high-resolution continuum source graphite furnace atomic absorption spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Borges, Aline R. [Instituto de Química, Universidade Federal do Rio Grande do Sul, Av. Bento Gonçalves 9500, 91501-970 Porto Alegre, RS (Brazil); Instituto Nacional de Ciência e Tecnologia do CNPq — INCT de Energia e Ambiente, Universidade Federal da Bahia, Salvador, BA (Brazil); Becker, Emilene M.; François, Luciane L.; Jesus, Alexandre de [Instituto de Química, Universidade Federal do Rio Grande do Sul, Av. Bento Gonçalves 9500, 91501-970 Porto Alegre, RS (Brazil); Vale, Maria Goreti R. [Instituto de Química, Universidade Federal do Rio Grande do Sul, Av. Bento Gonçalves 9500, 91501-970 Porto Alegre, RS (Brazil); Instituto Nacional de Ciência e Tecnologia do CNPq — INCT de Energia e Ambiente, Universidade Federal da Bahia, Salvador, BA (Brazil); Welz, Bernhard [Instituto Nacional de Ciência e Tecnologia do CNPq — INCT de Energia e Ambiente, Universidade Federal da Bahia, Salvador, BA (Brazil); Departamento de Química, Universidade Federal de Santa Catarina, 88040-900 Florianópolis, SC (Brazil); Dessuy, Morgana B., E-mail: mbdessuy@ufrgs.br [Instituto de Química, Universidade Federal do Rio Grande do Sul, Av. Bento Gonçalves 9500, 91501-970 Porto Alegre, RS (Brazil); Andrade, Jailson B. de [Instituto Nacional de Ciência e Tecnologia do CNPq — INCT de Energia e Ambiente, Universidade Federal da Bahia, Salvador, BA (Brazil)

    2014-11-01

    In the present work, spectral interferences on the determination of lead in fertilizer and limestone samples were investigated using high-resolution continuum source graphite furnace atomic absorption spectrometry at the main analytical lines: 217.001 and 283.306 nm. For these investigations, samples were introduced into the furnace as slurry together with a mixture of Pd and Mg as chemical modifier. Spectral interferences were observed for some samples at both analytical lines. In order to verify whether a wet digestion procedure would avoid these interferences, a reference method for wet digestion of fertilizers was employed as an alternative sample preparation procedure. However, the same interferences were also observed in the digested samples. In order to identify and eliminate the fine-structured background using a least-squares background correction, reference spectra were generated using the combination of different species. The use of the latter technique allowed the elimination of spectral interferences for most of the investigated samples, making possible the determination of lead in fertilizer and limestone samples free of interferences. The best results were found using a reference spectrum of NH{sub 4}H{sub 2}PO{sub 4} at 217.001 nm, and a mixture of H{sub 2}SO{sub 4} + Ca and HNO{sub 3} + Ca at the 283.306 nm line. The accuracy of the method was evaluated using a certified reference material “Trace Elements in Multi-Nutrient Fertilizer”. Similar results were obtained using line source graphite furnace atomic absorption spectrometry with Zeeman-effect background correction, indicating that the latter technique was also capable to correct the spectral interferences, at least in part. - Highlights: • Spectral interferences on the determination of lead in fertilizers and limestone. • The analytical lines at 217.001 nm and 283.306 nm using HR-CS GF AAS. • Various combinations of compounds were used to create reference spectra. • LSBC

  5. Positive matrix factorization as source apportionment of soil lead and cadmium around a battery plant (Changxing County, China).

    Science.gov (United States)

    Xue, Jian-long; Zhi, Yu-you; Yang, Li-ping; Shi, Jia-chun; Zeng, Ling-zao; Wu, Lao-sheng

    2014-06-01

    Chemical compositions of soil samples are multivariate in nature and provide datasets suitable for the application of multivariate factor analytical techniques. One of the analytical techniques, the positive matrix factorization (PMF), uses a weighted least square by fitting the data matrix to determine the weights of the sources based on the error estimates of each data point. In this research, PMF was employed to apportion the sources of heavy metals in 104 soil samples taken within a 1-km radius of a lead battery plant contaminated site in Changxing County, Zhejiang Province, China. The site is heavily contaminated with high concentrations of lead (Pb) and cadmium (Cd). PMF successfully partitioned the variances into sources related to soil background, agronomic practices, and the lead battery plants combined with a geostatistical approach. It was estimated that the lead battery plants and the agronomic practices contributed 55.37 and 29.28%, respectively, for soil Pb of the total source. Soil Cd mainly came from the lead battery plants (65.92%), followed by the agronomic practices (21.65%), and soil parent materials (12.43%). This research indicates that PMF combined with geostatistics is a useful tool for source identification and apportionment.

  6. Sulfide precursor concentration and lead source effect on PbS thin films properties

    Energy Technology Data Exchange (ETDEWEB)

    Beddek, L.; Messaoudi, M.; Attaf, N. [Laboratoire Couche Minces et Interfaces, Université frères Mentouri Constantine, 25000, Constantine (Algeria); Aida, M.S., E-mail: aida_salah2@yahoo.fr [Laboratoire Couche Minces et Interfaces, Université frères Mentouri Constantine, 25000, Constantine (Algeria); Bougdira, J. [Université de Lorraine, Institut Jean Lamour UMR 7198, Vandoeuvre 54506 (France)

    2016-05-05

    Lead sulfide (PbS) thin films were synthesized using chemical bath deposition (CBD). Bath solutions are formed of various concentrations of thiourea, sulfide source, ranged from 0.6 to 1.2 M and two different salts as Pb source (lead acetate and lead nitrate). From the growth mechanism, we inferred that PbS is formed through the ion by ion process when using acetate lead source, while, using nitrate source yields to films growth through the complex-decomposition process. Due to the difference in the involved growth process, lead acetate produces films with larger crystallite size (from 4 to 16 nm), smooth and dense films. However, lead nitrate produces rough films with smaller crystallite size (from 1 to 4 nm). Increasing the thiourea concentration results in crystallinity improvement when using lead acetate and, oppositely, in crystallinity degradation when using lead nitrate. Due to the quantum effect caused by the small crystallite sizes, the films optical gap is varied from 0.5 to 0.9 eV. - Highlights: • PbS thin films were synthesized by chemical bath deposition. • Ion by ion is the growth process when using the acetate lead source. • Deposition process is by complex-decomposition when using nitrate source. • Lead acetate yields to dense films with larger crystallite size. • Lead nitrate produces rough films with smaller crystallite size.

  7. Sulfide precursor concentration and lead source effect on PbS thin films properties

    International Nuclear Information System (INIS)

    Beddek, L.; Messaoudi, M.; Attaf, N.; Aida, M.S.; Bougdira, J.

    2016-01-01

    Lead sulfide (PbS) thin films were synthesized using chemical bath deposition (CBD). Bath solutions are formed of various concentrations of thiourea, sulfide source, ranged from 0.6 to 1.2 M and two different salts as Pb source (lead acetate and lead nitrate). From the growth mechanism, we inferred that PbS is formed through the ion by ion process when using acetate lead source, while, using nitrate source yields to films growth through the complex-decomposition process. Due to the difference in the involved growth process, lead acetate produces films with larger crystallite size (from 4 to 16 nm), smooth and dense films. However, lead nitrate produces rough films with smaller crystallite size (from 1 to 4 nm). Increasing the thiourea concentration results in crystallinity improvement when using lead acetate and, oppositely, in crystallinity degradation when using lead nitrate. Due to the quantum effect caused by the small crystallite sizes, the films optical gap is varied from 0.5 to 0.9 eV. - Highlights: • PbS thin films were synthesized by chemical bath deposition. • Ion by ion is the growth process when using the acetate lead source. • Deposition process is by complex-decomposition when using nitrate source. • Lead acetate yields to dense films with larger crystallite size. • Lead nitrate produces rough films with smaller crystallite size.

  8. Applications of lead isotope rations for identification and apportionment on pollution sources in food

    International Nuclear Information System (INIS)

    Zhao Duoyong; Wei Yimin; Guo Boli; Wei Shuai

    2011-01-01

    Lead is one of the toxic heavy metals which can accumulate to an adverse effect level in human bodies through ingestion, inhalation or other pathways. Because of the persistent lead contamination in farmland environment, large risk exists in the primary stage of 'from farm to table' chain. Environmental media such as soils, atmospheric aerosols were the possible lead sources of agro-food. To pinpoint the pollution sources exactly, cut off the contamination pathways in time, and reduce the risk of hazard, pollution sources tracing was very important. Lead isotope ratio combined with certain models is an effective method to discriminate correctly pollution sources and calculate the individual source contributions. In this review, to provide theoretical and technical reference for controlling lead pollution in environment and food, lead pollution sources in food, tracing principle and methods of lead isotope ratios, and its applications on vegetable, tea, wine, cereal and other food products were concerned. (authors)

  9. Children’s Blood Lead Seasonality in Flint, Michigan (USA), and Soil-Sourced Lead Hazard Risks

    Science.gov (United States)

    Laidlaw, Mark A.S.; Filippelli, Gabriel M.; Sadler, Richard C.; Gonzales, Christopher R.; Ball, Andrew S.; Mielke, Howard W.

    2016-01-01

    In Flint; MI; USA; a public health crisis resulted from the switching of the water supply from Lake Huron to a more corrosive source from the Flint River in April 2014; which caused lead to leach from water lines. Between 2010 and 2015; Flint area children’s average blood lead patterns display consistent peaks in the third quarter of the year. The third quarter blood lead peaks displayed a declining trend between 2010 and 2013; then rose abruptly between the third quarters of 2013 from 3.6% blood lead levels ≥5 µg/dL to a peak of about 7% in the third quarter of 2014; an increase of approximately 50%. The percentage of blood lead level ≥5 µg/dL in the first quarter of 2015 then dropped to 2.3%; which was the same percentage as the first quarter of 2014 (prior to the Flint River water source change). The Flint quarterly blood lead level peak then rose to about 6% blood lead levels ≥ 5 µg/dL in the third quarter of 2015; and then declined to about 2.5% in the fourth quarter of 2015. Soil lead data collected by Edible Flint food collaborative reveal generally higher soil lead values in the metropolitan center for Flint; with lower values in the outskirts of the city. The questions that are not being asked is why did children’s blood lead levels display a seasonal blood lead pattern before the introduction of the new water supply in Flint; and what are the implications of these seasonal blood lead patterns? Based upon previous findings in Detroit and other North American cities we infer that resuspension to the air of lead in the form of dust from lead contaminated soils in Flint appears to be a persistent contribution to lead exposure of Flint children even before the change in the water supply from Lake Huron to the Flint River. PMID:27023578

  10. Identification of lead sources in residential environments: Sydney Australia

    International Nuclear Information System (INIS)

    Laidlaw, M.A.S.; Zahran, S.; Pingitore, N.; Clague, J.; Devlin, G.; Taylor, M.P.

    2014-01-01

    Interior and exterior dust, soil and paint were analysed at five brick urban Sydney homes over 15 months to evaluate temporal variations and discriminate sources of lead (Pb) exposure. Exterior dust gauge Pb loading rates (μg/m 2 /28 days), interior vacuum dust Pb concentrations (mg/kg) and interior petri-dish Pb loading rates (μg/m 2 /28 days), were correlated positively with soil Pb concentrations. Exterior dust gauge Pb loading rates and interior vacuum dust Pb concentrations peaked in the summer. Lead isotope and Pb speciation (XAS) were analysed in soil and vacuum dust samples from three of the five houses that had elevated Pb concentrations. Results show that the source of interior dust lead was primarily from soil in two of the three houses and from soil and Pb paint in the third home. IEUBK child blood Pb modelling predicts that children's blood Pb levels could exceed 5 μg/dL in two of the five houses. -- Highlights: • Exterior Pb loading and interior Pb dust loading and concentrations correlate with soil Pb. • Exterior dust gauge Pb loading rates and interior vacuum dust Pb concentrations peak in the summer. • Interior dust lead came from soil in two of the three houses and from soil and Pb paint in the third home. • Modelling predicts that children's blood Pb levels could exceed 5 μg/dL in two of the five houses. -- Interior and exterior dust, soil and paint were analysed at five brick urban Sydney homes over 15 months to evaluate temporal variations and discriminate sources of lead (Pb) exposure

  11. Urban airborne lead: X-ray absorption spectroscopy establishes soil as dominant source.

    Science.gov (United States)

    Pingitore, Nicholas E; Clague, Juan W; Amaya, Maria A; Maciejewska, Beata; Reynoso, Jesús J

    2009-01-01

    Despite the dramatic decrease in airborne lead over the past three decades, there are calls for regulatory limits on this potent pediatric neurotoxin lower even than the new (2008) US Environmental Protection Agency standard. To achieve further decreases in airborne lead, what sources would need to be decreased and what costs would ensue? Our aim was to identify and, if possible, quantify the major species (compounds) of lead in recent ambient airborne particulate matter collected in El Paso, TX, USA. We used synchrotron-based XAFS (x-ray absorption fine structure) to identify and quantify the major Pb species. XAFS provides molecular-level structural information about a specific element in a bulk sample. Pb-humate is the dominant form of lead in contemporary El Paso air. Pb-humate is a stable, sorbed complex produced exclusively in the humus fraction of Pb-contaminated soils; it also is the major lead species in El Paso soils. Thus such soil must be the dominant source, and its resuspension into the air, the transfer process, providing lead particles to the local air. Current industrial and commercial activity apparently is not a major source of airborne lead in El Paso, and presumably other locales that have eliminated such traditional sources as leaded gasoline. Instead, local contaminated soil, legacy of earlier anthropogenic Pb releases, serves as a long-term reservoir that gradually leaks particulate lead to the atmosphere. Given the difficulty and expense of large-scale soil remediation or removal, fugitive soil likely constrains a lower limit for airborne lead levels in many urban settings.

  12. Successful application of lead isotopes in source apportionment, legal proceedings, remediation and monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Gulson, Brian, E-mail: brian.gulson@mq.edu.au [Graduate School of the Environment, Faculty of Science, Macquarie University, Sydney, NSW 2109 (Australia); CSIRO Earth Science and Resource Engineering North Ryde, NSW 1670 (Australia); Korsch, Michael [CSIRO Earth Science and Resource Engineering North Ryde, NSW 1670 (Australia); Winchester, Wayne; Devenish, Matthew; Hobbs, Thad [Esperance Cleanup and Recovery Project, Western Australia (WA) Department of Transport, Esperance 6450 (Australia); Main, Cleve; Smith, Gerard [Animal Health Laboratory, Department of Agriculture and Food, Perth 6151, WA (Australia); Rosman, Kevin; Howearth, Lynette; Burn-Nunes, Laurie [Curtin University, Department of Imaging and Applied Physics, Bentley 6102, WA (Australia); Seow, Jimmy; Oxford, Cameron [Department of Environment and Conservation, Booragoon 6154, WA (Australia); Yun, Gracie; Gillam, Lindsay [Department of Health, East Perth 6004, WA (Australia); Crisp, Michelle [LED (Locals for Esperance Development), Esperance 6450, WA (Australia)

    2012-01-15

    In late 2006, the seaside community in Esperance Western Australia was alerted to thousands of native bird species dying. The source of the lead (Pb) was determined by Pb isotopes to derive from the handling of Pb carbonate concentrate through the Port, which began in July 2005. Concern was expressed for the impact of this on the community. Our objectives were to employ Pb isotope ratios to evaluate the source of Pb in environmental samples for use in legal proceedings, and for use in remediation and monitoring. Isotope measurements were undertaken of bird livers, plants, drinking water, soil, harbour sediments, air, bulk ceiling dust, gutter sludge, surface swabs and blood. The unique lead isotopic signature of the contaminating Pb carbonate enabled diagnostic apportionment of lead in samples. Apart from some soil and water samples, the proportion of contaminating Pb was >95% in the environmental samples. Lead isotopes were critical in resolving legal proceedings, are being used in the remediation of premises, were used in monitoring of workers involved in the decontamination of the storage facility, and monitoring transport of the concentrate through another port facility. Air samples show the continued presence of contaminant Pb, more than one year after shipping of concentrate ceased, probably arising from dust resuspension. Brief details of the comprehensive testing and cleanup of the Esperance community are provided along with the role of the Community. Lead isotopic analyses can provide significant benefits to regulatory agencies, interested parties, and the community where the signature is able to be characterised with a high degree of certainty. - Highlights: Black-Right-Pointing-Triangle Lead carbonate concentrate. Black-Right-Pointing-Triangle Successful use of Pb isotopes in identifying sources of Pb arising from transport and shipping. Black-Right-Pointing-Triangle Use of Pb isotopes in legal proceedings and their use in cleanup of residences. Black

  13. Determination of Crack Area on Lead Apron used in Diagnostic Radiology

    International Nuclear Information System (INIS)

    Norriza Mohd Isa; Muhammad Jamal Muhammad Isa; Asmaliza Hashim

    2014-01-01

    The study was performed to determine crack area of lead aprons used by personnel as radiation protector from unnecessary radiation in diagnostic radiology. The experiment was done using general X-ray and Computed Radiography (CR) systems. Calibration curve was plotted for beam quality at 80 kVp and source to detector distance (SDD) is 100 cm by selecting manual exposure mode. Lead sheet with thickness from 0.1 to 1.0 mm were used for this purpose. It was used to relate the pixel value of lead sheet images with their thickness. A few sample of lead aprons with different thickness from a hospital and our laboratories were obtained and then undergoing the inspection at our laboratory through this procedure. The samples were divided with two groups based on how long they were used which are less 10 years and more than 10 years. The images data of the sample were obtained and analysis using our developed software. The reference object with known its area was also used in the experiment to ensure our output using the software is reliable and acceptable. The results shown that lead aprons used more than 10 years have depicted more crack areas compare with the lead apron used less than 10 years. (author)

  14. Lead isotope ratios in artists' lead white: a progress report

    Energy Technology Data Exchange (ETDEWEB)

    Keisch, B; Callahan, R C [Carnegie-Mellon Univ., Pittsburgh, Pa. (USA)

    1976-07-01

    The lead isotope ratios in over four hundred samples of lead white have been determined. The samples represent various geographical sources and dates from the thirteenth century to the present. A new method for organizing this large volume of data is described which helps with the visualization of temporal and geographic patterns. A number of interesting relationships between lead isotope ratio and date or source are shown to exist. Some examples of successful applications of this methodology are described.

  15. Urban airborne lead: X-ray absorption spectroscopy establishes soil as dominant source.

    Directory of Open Access Journals (Sweden)

    Nicholas E Pingitore

    Full Text Available BACKGROUND: Despite the dramatic decrease in airborne lead over the past three decades, there are calls for regulatory limits on this potent pediatric neurotoxin lower even than the new (2008 US Environmental Protection Agency standard. To achieve further decreases in airborne lead, what sources would need to be decreased and what costs would ensue? Our aim was to identify and, if possible, quantify the major species (compounds of lead in recent ambient airborne particulate matter collected in El Paso, TX, USA. METHODOLOGY/PRINCIPAL FINDINGS: We used synchrotron-based XAFS (x-ray absorption fine structure to identify and quantify the major Pb species. XAFS provides molecular-level structural information about a specific element in a bulk sample. Pb-humate is the dominant form of lead in contemporary El Paso air. Pb-humate is a stable, sorbed complex produced exclusively in the humus fraction of Pb-contaminated soils; it also is the major lead species in El Paso soils. Thus such soil must be the dominant source, and its resuspension into the air, the transfer process, providing lead particles to the local air. CONCLUSIONS/SIGNIFICANCE: Current industrial and commercial activity apparently is not a major source of airborne lead in El Paso, and presumably other locales that have eliminated such traditional sources as leaded gasoline. Instead, local contaminated soil, legacy of earlier anthropogenic Pb releases, serves as a long-term reservoir that gradually leaks particulate lead to the atmosphere. Given the difficulty and expense of large-scale soil remediation or removal, fugitive soil likely constrains a lower limit for airborne lead levels in many urban settings.

  16. Alluvial and riparian soils as major sources of lead exposure in young children in the Philippines: the role of floods.

    Science.gov (United States)

    Ostrea, Enrique M; Ostrea, Angelo M; Villanueva-Uy, Ma Esterlita; Chiodo, Lisa; Janisse, James

    2015-04-01

    The objective of this paper was to determine the prevalence and sources of high lead (Pb) exposure among children in Bulacan, Philippines. A total of 150 children (6-7 years old) and their caregivers were studied. Lead was analyzed in children hair and deciduous teeth. Sources of lead exposure were determined by caregiver interview and Pb analysis of house soil, drinking faucet water, air, and water from seven Bulacan rivers. Lead was positive in 91.3% of children's hair (MC or median concentration = 8.9 μg/g; range = 0-38.29), in 46.2% of the teeth (MC = 0.000 μg/mg in positive samples; range = 0.00-0.020), in 100% of soil (MC = 27.06 mg/kg; range = 3.05-1155.80), in 21.1% of air (MC = 0 μg/Ncm; range = 0-0.10), in 4% of house, faucet water (MC = 0.0 ppm; range = 0-40). There was a significant correlation (Spearman's rho) between Pb in children's hair and soil (r = 0.195; p = 0.017) and between Pb in house water and outdoor air (r = 0.616; p = 0.005). There is no significant correlation between Pb in children's hair and teeth. None of the potential sources of Pb from interview were related to lead exposure in the children. Water from seven Bulacan rivers was 100% positive for lead (MC = 70.00 ppb; range = 30-90). Widespread flooding with river overflow occurred in Bulacan in 2009 which likely caused lead contamination of the soil. There was no significant difference in the lead concentration of the soil whether near or far from the river (p = 0.205, Mann-Whitney U test). High lead exposure in children in Bulacan is likely from soil contaminated by lead-polluted rivers during flooding. In areas where flooding is common, alluvial and riparian soils from polluted rivers are important sources of lead exposure in children.

  17. Lead isotopic fingerprinting of aerosols to characterize the sources of atmospheric lead in an industrial city of India

    Science.gov (United States)

    Sen, Indra S.; Bizimis, Michael; Tripathi, Sachchida Nand; Paul, Debajyoti

    2016-03-01

    Anthropogenic Pb in the environment is primarily sourced from combustion of fossil fuel and high-temperature industries such as smelters. Identifying the sources and pathways of anthropogenic Pb in the environment is important because Pb toxicity is known to have adverse effects on human health. Pb pollution sources for America, Europe, and China are well documented. However, sources of atmospheric Pb are unknown in India, particularly after leaded gasoline was phased out in 2000. India has a developing economy with a rapidly emerging automobile and high temperature industry, and anthropogenic Pb emission is expected to rise in the next decade. In this study, we report on the Pb-isotope compositions and trace metal ratios of airborne particulates collected in Kanpur, a large city in northern part of India. The study shows that the PM10 aerosols had elevated concentration of Cd, Pb, Zn, As, and Cu in the Kanpur area, however their concentrations are well below the United States Environmental Protection Agency chronic exposure limit. Lead isotopic and trace metal data reveal industrial emission as the plausible source of anthropogenic Pb in the atmosphere in Kanpur. However, Pb isotopic compositions of potential source end-members are required to fully evaluate Pb contamination in India over time. This is the first study that characterizes the isotopic composition of atmospheric Pb in an Indian city after leaded gasoline was phased out by 2000.

  18. Lead isotope ratios in artists' lead white: a progress report

    International Nuclear Information System (INIS)

    Keisch, B.; Callahan, R.C.

    1976-01-01

    The lead isotope ratios in over four hundred samples of lead white have been determined. The samples represent various geographical sources and dates from the thirteenth century to the present. A new method for organizing this large volume of data is described which helps with the visualization of temporal and geographic patterns. A number of interesting relationships between lead isotope ratio and date or source are shown to exist. Some examples of successful applications of this methodology are described. (author)

  19. Using trace element content and lead isotopic composition to assess sources of PM in Tijuana, Mexico

    Science.gov (United States)

    Salcedo, D.; Castro, T.; Bernal, J. P.; Almanza-Veloz, V.; Zavala, M.; González-Castillo, E.; Saavedra, M. I.; Perez-Arvízu, O.; Díaz-Trujillo, G. C.; Molina, L. T.

    2016-05-01

    PM2.5 samples were collected at two urban sites (Parque Morelos (PQM) and CECyTE (CEC)) in Tijuana during the Cal-Mex campaign from May 24 to June 5, 2010. Concentration of trace elements (Mg, Al, Ti, V, Mn, Fe, Co, Ni, Zn, Cu, Ga, As, Se, Rb, Sr, Mo, Cd, Sn, Sb, Ba, La, Ce, and Pb), and Pb isotopic composition were determined in order to study the sources of PM impacting each site. Other chemical analysis (gravimetric, elemental and organic carbon (EC/OC), and polycyclic aromatic hydrocarbons (PAHs)), were also performed. Finally, back-trajectories were calculated to facilitate the interpretation of the chemical data. Trace elements results show that CEC is a receptor site affected by mixed regional sources: sea salt, mineral, urban, and industrial. On the other hand, PQM seems to be impacted mainly by local sources. In particular, Pb at CEC is of anthropogenic, as well as crustal origin. This conclusion is supported by the lead isotopic composition, whose values are consistent with a combination of lead extracted from US mines, and lead from bedrocks in the Mexican Sierras. Some of the time variability observed can be explained using the back-trajectories.

  20. Lead Contamination and Source Characterization in Soils Around a Lead-Zinc Smelting Plant in a Near-Urban Environment in Baoji, China.

    Science.gov (United States)

    Deng, Wenbo; Li, Xuxiang; An, Zhisheng; Yang, Liu

    2016-11-01

    Economic reforms in China since 1978 have promoted nationwide socioeconomic advancement but led to a considerable amount of environmental pollution. The distribution and sources of Pb in a typical peri-urban industrial part of Baoji, China, were assessed by determining the Pb contents and isotopic compositions in 52 topsoil samples from the study area. The topsoil samples were polluted averagely with 40.88 mg Pb kg -1 , was 1.86 times higher than the Pb content of local background soil (22.04 mg kg -1 ). Pb isotopic compositions were determined by analyzing samples prepared using total digestion and acid extraction methods. Radiogenic isotopes contributed more to the Pb concentrations in the acid extracts than in the total digests. This was shown by the 207/206 Pb and 208/206 Pb ratios, which were 0.845-0.88 and 2.088-2.128, respectively, in the acid extracts and 0.841-0.875 and 2.086-2.125, respectively, in the total digests. This indicates that anthropogenic sources of Pb could be identified more sensitively in acid extracts than in total digests. The Pb isotope ratios showed that burning coal and smelting ore are the predominant anthropogenic sources of Pb in the study area, i.e., a lead-zinc smelter and a coking plant are major sources of Pb in the study area.

  1. Spectrochemical determination of lead in wines

    Directory of Open Access Journals (Sweden)

    DRAGAN MARKOVIC

    2000-06-01

    Full Text Available The determination of lead in wines of different origin was performed by means of atomic emission spectroscopy with argon stabilized DC. U-shaped arc and electrothermal atomic absorption spectrometry. The comparison of the results obtained by the direct and standard addition method has indicated the presence of a depressive effect of the complex organic matrix. The effect is avoided successfully by mineralization, as well as by dissolution of the samples. Thus, a relative simple but precise and sensitive method involving the application of a stabilized arc and photoelectric detection with time integration of the emission signals is recommended for the determination of low concentrations of lead in wines. The complex organic matrix was investigated by recording the IR spectra of different wine fractions.

  2. E-Waste Informal Recycling: An Emerging Source of Lead Exposure in South America.

    Science.gov (United States)

    Pascale, Antonio; Sosa, Adriana; Bares, Cristina; Battocletti, Alejandra; Moll, María José; Pose, Darío; Laborde, Amalia; González, Hugo; Feola, Gabriella

    2016-01-01

    Primitive electronic waste (e-waste) recycling creates exposures to several hazardous substances including lead. In Uruguay, primitive recycling procedures are a significant source of lead exposure. The aim of this study was to examine lead exposure in blood lead levels (BLLs) in low-income children exposed to lead through burning cables. A sample of children and adolescents exposed to lead through burning cable activities were assessed at the Department of Toxicology in Montevideo, Uruguay, between 2010 and 2014. Soil lead levels of residences were taken shortly after their assessment. The final sample included 69 children and adolescents (mean age 7.89 years). More than 66% of participants had an additional source of lead exposure-manual gathering of metals-and based paint (r = 0.23; P source of lead exposure was the manual gathering of metals. The average BLL among children and adolescents in this study is higher than the BLLs currently suggested in medical intervention. Future research should focus on exploring effective interventions to reduce lead exposure among this vulnerable group. Copyright © 2016 The Authors. Published by Elsevier Inc. All rights reserved.

  3. Lead exposure in indigenous children of the Peruvian Amazon : seeking the hidden source,venturing into participatory research

    OpenAIRE

    Anticona Huaynate, Cynthia

    2012-01-01

    Introduction. In 2006, a Peruvian environmental agency reported the presence of elevated blood lead levels (BLLs) in indigenous communities of the Corrientes river basin. This is a territory in the Peruvian Amazon where oil activity has been associated with serious environmental effects, with impact on an ongoing social conflict. This PhD project aimed to determine the lead sources, risk factors and pathways in children of these communities and to suggest control and prevention strategies. Gi...

  4. Successful application of lead isotopes in source apportionment, legal proceedings, remediation and monitoring.

    Science.gov (United States)

    Gulson, Brian; Korsch, Michael; Winchester, Wayne; Devenish, Matthew; Hobbs, Thad; Main, Cleve; Smith, Gerard; Rosman, Kevin; Howearth, Lynette; Burn-Nunes, Laurie; Seow, Jimmy; Oxford, Cameron; Yun, Gracie; Gillam, Lindsay; Crisp, Michelle

    2012-01-01

    In late 2006, the seaside community in Esperance Western Australia was alerted to thousands of native bird species dying. The source of the lead (Pb) was determined by Pb isotopes to derive from the handling of Pb carbonate concentrate through the Port, which began in July 2005. Concern was expressed for the impact of this on the community. Our objectives were to employ Pb isotope ratios to evaluate the source of Pb in environmental samples for use in legal proceedings, and for use in remediation and monitoring. Isotope measurements were undertaken of bird livers, plants, drinking water, soil, harbour sediments, air, bulk ceiling dust, gutter sludge, surface swabs and blood. The unique lead isotopic signature of the contaminating Pb carbonate enabled diagnostic apportionment of lead in samples. Apart from some soil and water samples, the proportion of contaminating Pb was >95% in the environmental samples. Lead isotopes were critical in resolving legal proceedings, are being used in the remediation of premises, were used in monitoring of workers involved in the decontamination of the storage facility, and monitoring transport of the concentrate through another port facility. Air samples show the continued presence of contaminant Pb, more than one year after shipping of concentrate ceased, probably arising from dust resuspension. Brief details of the comprehensive testing and cleanup of the Esperance community are provided along with the role of the Community. Lead isotopic analyses can provide significant benefits to regulatory agencies, interested parties, and the community where the signature is able to be characterised with a high degree of certainty. Crown Copyright © 2011. Published by Elsevier Inc. All rights reserved.

  5. Sources and characteristics of lead pollution in the urban environment of Guangzhou

    International Nuclear Information System (INIS)

    Duzgoren-Aydin, Nurdan S.

    2007-01-01

    Guangzhou, the capital of the southeastern province of Guangdong, is one of the largest and most rapidly developing industrial cities in China. In recent years its rapid economic development has brought great prosperity to the Pearl River Delta (PRD) region, but has also given rise to a wide variety of environmental problems. The current level of lead (Pb) contamination (75-926 mg/kg) in the surface environment of Guangzhou remains a major concern, even though the use of leaded petrol in the city was banned in 1997. The Pb isotope ratios ( 206 Pb/ 207 Pb min-max : 1.1612-1.1961 and 208 Pb/ 207 Pb min-max : 2.4495-2.4838) of the urban dusts from unconfined (road dusts and gully sediments) and relatively confined (vehicular tunnel) settings in Guangzhou remains in a relatively narrow range, comparable with those of the regional natural and anthropogenic sources. This study highlights the inherent shortcomings of the Pb isotope fingerprinting technique for provenancing Pb sources, as both the target media (urban dusts) and potential sources have similar and highly radiogenic Pb isotope values. This could not only lead to an overestimation of the effectiveness of phasing-out of leaded petrol, but also an underestimation of the ever-increasing relative contributions from other potential sources of pollution, including coal combustion, industrial emissions of local Pb-ores and non-additive Pb contents of crude oils. Re-suspended Pb-bearing particulates deposited from early vehicular exhaust emission of leaded petrol with distinctly low Pb isotope compositions are still an important source of Pb pollution in the region

  6. Identification of the sources of metal (lead) contamination in drinking waters in north-eastern Tasmania using lead isotopic compositions.

    Science.gov (United States)

    Harvey, P J; Handley, H K; Taylor, M P

    2015-08-01

    This study utilises a range of scientific approaches, including lead isotopic compositions, to differentiate unknown sources of ongoing lead contamination of a drinking water supply in north-eastern Tasmania, Australia. Drinking water lead concentrations are elevated above the Australian Drinking Water Guideline (10 μg/L), reaching 540 μg/L in the supply network. Water lead isotopic compositions from the town of Pioneer ((208)Pb/(207)Pb 2.406, (206)Pb/(207)Pb 1.144 to (208)Pb/(207)Pb 2.360, (206)Pb/(207)Pb 1.094) and Ringarooma ((208)Pb/(207)Pb 2.398, (206)Pb/(207)Pb 1.117) are markedly different from the local bedrock ((208)Pb/(207)Pb 2.496, (206)Pb/(207)Pb 1.237). The data show that the lead in the local waters is sourced from a combination of dilapidated drinking water infrastructure, including lead jointed pipelines, end-of-life polyvinyl chloride pipes and household plumbing. Drinking water is being inadvertently contaminated by aging infrastructure, and it is an issue that warrants investigation to limit the burden of disease from lead exposure.

  7. Calibration equations for energy-dispersive XRF determination of copper, iron and lead in copper ore slurries

    International Nuclear Information System (INIS)

    Lakosz, M.

    1976-01-01

    Calibration equations for the X-ray fluorescence analysis determination of copper, iron and lead in copper ore slurries have been derived and tested. The measurement of Ksub(α) lines of copper and iron and Lsub(α) line of lead excited by rays from 238 Pu source have been used. Si/Li detector coupled to multichannel analyzer and minicomputer have been applied in measurements. The matrix and density effect have been eliminated by additional measurement of back-scattered primary radiation. (author)

  8. Monitoring light source for CMS lead tungstate crystal calorimeter at LHC

    CERN Document Server

    Zhang Li Yuan; Zhu Ren Yuan; Liu Dun Can

    2000-01-01

    Light monitoring will serve as an inter calibration for CMS lead tungstate crystals in situ at LHC, which is crucial for maintaining crystal calorimeter's sub percent constant term in the energy resolution. This paper presents the design of the CMS ECAL monitoring light source and high level distribution system. The correlations between variations of the light output and the transmittance for the CMS choice of Y doped PbWO//4 crystals were investigated, and were used to study monitoring linearity and sensitivity as a function of the wavelength. The monitoring wavelength was determined so that a good linearity as well as adequate sensitivity can be achieved. The performance of a custom manufactured tunable laser system is presented. Issues related to monitoring precision are discussed. 29 Refs.

  9. Sources of variability in collection and preparation of paint and lead-coating samples.

    Science.gov (United States)

    Harper, S L; Gutknecht, W F

    2001-06-01

    Chronic exposure of children to lead (Pb) can result in permanent physiological impairment. Since surfaces coated with lead-containing paints and varnishes are potential sources of exposure, it is extremely important that reliable methods for sampling and analysis be available. The sources of variability in the collection and preparation of samples were investigated to improve the performance and comparability of methods and to ensure that data generated will be adequate for its intended use. Paint samples of varying sizes (areas and masses) were collected at different locations across a variety of surfaces including metal, plaster, concrete, and wood. A variety of grinding techniques were compared. Manual mortar and pestle grinding for at least 1.5 min and mechanized grinding techniques were found to generate similar homogenous particle size distributions required for aliquots as small as 0.10 g. When 342 samples were evaluated for sample weight loss during mortar and pestle grinding, 4% had 20% or greater loss with a high of 41%. Homogenization and sub-sampling steps were found to be the principal sources of variability related to the size of the sample collected. Analysis of samples from different locations on apparently identical surfaces were found to vary by more than a factor of two both in Pb concentration (mg cm-2 or %) and areal coating density (g cm-2). Analyses of substrates were performed to determine the Pb remaining after coating removal. Levels as high as 1% Pb were found in some substrate samples, corresponding to more than 35 mg cm-2 Pb. In conclusion, these sources of variability must be considered in development and/or application of any sampling and analysis methodologies.

  10. Cadmium, mercury, and lead in kidney cortex of living kidney donors: Impact of different exposure sources,

    Energy Technology Data Exchange (ETDEWEB)

    Barregard, Lars, E-mail: lars.barregard@amm.gu.se [Department of Occupational and Environmental Medicine, Sahlgrenska University Hospital and University of Gothenburg, P.O. Box 414, SE 405 30 Gothenburg (Sweden); Fabricius-Lagging, Elisabeth [Department of Nephrology, Sahlgrenska University Hospital and Boras Hospital (Sweden); Lundh, Thomas [Department of Occupational and Environmental Medicine, Lund University Hospital and Lund University (Sweden); Moelne, Johan [Department of Clinical Pathology, Sahlgrenska University Hospital and University of Gothenburg (Sweden); Wallin, Maria [Department of Occupational and Environmental Medicine, Sahlgrenska University Hospital and University of Gothenburg, P.O. Box 414, SE 405 30 Gothenburg (Sweden); Olausson, Michael [Department of Transplantation and Liver Surgery, Sahlgrenska University Hospital and University of Gothenburg (Sweden); Modigh, Cecilia; Sallsten, Gerd [Department of Occupational and Environmental Medicine, Sahlgrenska University Hospital and University of Gothenburg, P.O. Box 414, SE 405 30 Gothenburg (Sweden)

    2010-01-15

    Background: Most current knowledge on kidney concentrations of nephrotoxic metals like cadmium (Cd), mercury (Hg), or lead (Pb) comes from autopsy studies. Assessment of metal concentrations in kidney biopsies from living subjects can be combined with information about exposure sources like smoking, diet, and occupation supplied by the biopsied subjects themselves. Objectives: To determine kidney concentrations of Cd, Hg, and Pb in living kidney donors, and assess associations with common exposure sources and background factors. Methods: Metal concentrations were determined in 109 living kidney donors aged 24-70 years (median 51), using inductively coupled plasma-mass spectrometry (Cd and Pb) and cold vapor atomic fluorescence spectrometry (Hg). Smoking habits, occupation, dental amalgam, fish consumption, and iron stores were evaluated. Results: The median kidney concentrations were 12.9 {mu}g/g (wet weight) for cadmium, 0.21 {mu}g/g for mercury, and 0.08 {mu}g/g for lead. Kidney Cd increased by 3.9 {mu}g/g for a 10 year increase in age, and by 3.7 {mu}g/g for an extra 10 pack-years of smoking. Levels in non-smokers were similar to those found in the 1970s. Low iron stores (low serum ferritin) in women increased kidney Cd by 4.5 {mu}g/g. Kidney Hg increased by 6% for every additional amalgam surface, but was not associated with fish consumption. Lead was unaffected by the background factors surveyed. Conclusions: In Sweden, kidney Cd levels have decreased due to less smoking, while the impact of diet seems unchanged. Dental amalgam is the main determinant of kidney Hg. Kidney Pb levels are very low due to decreased exposure.

  11. Cadmium, mercury, and lead in kidney cortex of living kidney donors: Impact of different exposure sources,

    International Nuclear Information System (INIS)

    Barregard, Lars; Fabricius-Lagging, Elisabeth; Lundh, Thomas; Moelne, Johan; Wallin, Maria; Olausson, Michael; Modigh, Cecilia; Sallsten, Gerd

    2010-01-01

    Background: Most current knowledge on kidney concentrations of nephrotoxic metals like cadmium (Cd), mercury (Hg), or lead (Pb) comes from autopsy studies. Assessment of metal concentrations in kidney biopsies from living subjects can be combined with information about exposure sources like smoking, diet, and occupation supplied by the biopsied subjects themselves. Objectives: To determine kidney concentrations of Cd, Hg, and Pb in living kidney donors, and assess associations with common exposure sources and background factors. Methods: Metal concentrations were determined in 109 living kidney donors aged 24-70 years (median 51), using inductively coupled plasma-mass spectrometry (Cd and Pb) and cold vapor atomic fluorescence spectrometry (Hg). Smoking habits, occupation, dental amalgam, fish consumption, and iron stores were evaluated. Results: The median kidney concentrations were 12.9 μg/g (wet weight) for cadmium, 0.21 μg/g for mercury, and 0.08 μg/g for lead. Kidney Cd increased by 3.9 μg/g for a 10 year increase in age, and by 3.7 μg/g for an extra 10 pack-years of smoking. Levels in non-smokers were similar to those found in the 1970s. Low iron stores (low serum ferritin) in women increased kidney Cd by 4.5 μg/g. Kidney Hg increased by 6% for every additional amalgam surface, but was not associated with fish consumption. Lead was unaffected by the background factors surveyed. Conclusions: In Sweden, kidney Cd levels have decreased due to less smoking, while the impact of diet seems unchanged. Dental amalgam is the main determinant of kidney Hg. Kidney Pb levels are very low due to decreased exposure.

  12. Lead in game birds in Denmark - levels and sources

    DEFF Research Database (Denmark)

    Kanstrup, Niels

    2012-01-01

    In June 2008, the National Food Agency contacted Bjarne Frost Vildt against the background that the Danish surveillance of heavy metals in food (EU Directive 96/23 of 29 April 1996) had, for several years, shown elevated lead levels in game meat. These elevated levels exceeded the official...... project to identify the source of lead in game meat. In July 2008, the Danish Academy of Hunting was tasked to design and carry out the investigation, in cooperation with the Veterinary Institute (Technical University of Denmark) and Food Region North (Ministry of Food, Agriculture and Fisheries....../2009 and 2009/2010 may be driven by three The biggest Danish butchery for game meat different reasons: reduced illegal use of lead shot due to the campaign initiated in 2008; reduced concentration of lead in bismuth shot (2009/2010) due to the conclusions of this study; and/or reluctance to deliver pheasants...

  13. Tracing the anthropogenic lead sources in coastal sediments of SE-Pacific (36 deg. Lat. S) using stable lead isotopes

    International Nuclear Information System (INIS)

    Munoz, Praxedes N.V.; Garbe-Schoenberg, Carl-Dieter; Salamanca, Marco A.

    2004-01-01

    This study evaluates the main sources of antropogenic Pb in one of the most industrialized centers of the southern Chilean coast (36 deg. S). Stable lead isotopes ( 206 Pb/ 207 Pb, 208 Pb/ 207 Pb) were used to trace main Pb sources to coastal sediments, considering the suspended particulate matter (SPM) from marine (traps), continental (rivers) and industrial effluents, sediments and leaded gasoline samples. The atmospheric input was evaluated through natural collectors; i.e. Raqui-Tubul salt marsh. Results show that marine samples lie on a trend between industrial effluents (∼1.16, 2.44) and natural sources (1.20, 2.50), not related to gasoline consumption. Salt marsh sediments show comparable isotopic composition to marine samples, suggesting the importance of the atmospheric input in the coastal sediments, not related to the leaded gasoline composition either. The continental input (1.18, 2.48) is highly influenced by precipitation, being difficult to separate both sources (atmosphere and continental runoff), showing also similar isotopic ratio to marine sediments. The signal of industrial emissions is masked with the introduction of Pb with higher isotopic ratios, compared to the values observed in the material collected from traps (SPM ∼1.19, 2.48). The contribution of more radiogenic Pb by the upwelling is suggested

  14. Monitoring light source for CMS lead tungstate crystal calorimeter at LHC

    CERN Document Server

    Zhang Liang Ying; Zhu, R Y; Liu, D T

    2001-01-01

    Light monitoring will serve as an intercalibration for Compact Muon Solenoid (CMS) lead tungstate crystals in situ at the Large Hadronic Collider, which is crucial for maintaining crystal calorimeter's subpercent constant term in the energy resolution. This paper presents the design of the CMS electromagnetic calorimeter monitoring light source and high-level distribution system. The correlations between variations of the light output and the transmittance for the CMS choice of yttrium-doped PbWO/sub 4/ crystals were investigated and were used to study monitoring linearity and sensitivity as a function of wavelength. The monitoring wavelength was determined so that a good linearity as well as adequate sensitivity can be achieved. The performance of a custom manufactured tunable laser system is presented. Issues related to monitoring precision are discussed. (12 refs).

  15. Determination of 210Pb activity concentration in lead shielding

    International Nuclear Information System (INIS)

    Slivka, J.; Mrdja, D.; Varga, E.; Veskovic, M.

    2005-01-01

    210 Pb is concentrated during the separation lead from the ore and therefore it is the main pollutant of lead products. The content of this isotope limits the applicability of lead for low-level shielding of gamma spectrometers. In this paper, a new method for the determination of 210 Pb activity concentration in lead shielding from 46.5 keV gamma line intensity is presented. (author) [sr

  16. Determination of spatial continuity of soil lead levels in an urban residential neighborhood

    Energy Technology Data Exchange (ETDEWEB)

    Shinn, N.J.; Bing-Canar, J.; Cailas, M.; Peneff, N.; Binns, H.J.

    2000-01-01

    This study uses geostatistical techniques to model and estimate soil lead levels in an urban, residential neighborhood. Sixty-two composite soil samples in a four-block area of brick and stone homes were obtained. The spatial continuity of soil lead levels was modeled with a semi-variogram, which was then used to estimate lead levels at unsampled locations, a process called kriging. Because soil lead levels were spatially correlated, it is likely that a nonrandom process generated the lead distribution found. This finding signifies the existence of lead sources which were tentatively identified on historical maps of the area and from past traffic volume patterns. The distribution of kriged estimates of soil lead levels provides an explanatory tool for exploring and identifying potential sources and may be useful for targeting urban soil abatement efforts.

  17. Determinants of blood-lead levels in children in Callao and Lima metropolitan area

    Directory of Open Access Journals (Sweden)

    Espinoza Rocío

    2003-01-01

    Full Text Available OBJECTIVES: To determine blood lead levels in urban populations of children (n=2 510 and women (n=874 in the early postpartum in certain districts of Lima and Callao, and to correlate those levels with particular exposures. MATERIAL AND METHODS: Between July 1998 and January 1999 cross sectional study was conducted. The study population was selected using three sampling strategies in the government operated school system and from public pediatric and maternity hospitals at Lima and Callao, Peru. Study personnel were trained to collect finger stick blood samples with a protocol that minimizes external lead contamination. Lead determinations in blood and environmental samples were performed at the study site using portable anodic striping voltamenters. To determine the simultaneous effects of different predictors on blood lead levels, multivariate regression models were used to estimate adjusted mean differences. RESULTS: The mean blood lead level in the children studied was 9.9 µg/dl ranging from I µg/dl to 64 µg/dl with 29% of the children displaying values greater than 10 µg/dl and 9.4% at levels greater than 20 µg/dl. Among the women, the mean was 3.5 µg/dl (SD=2.4 µg/dl, and 2.4% (n=21 displayed levels greater than 10 µg/dl. Important differences were observed between the sample locations, and the highest levels were documented in the port region near Callao. The mean level of blood lead in this group was 25.6 µg/dl (SD=4.6 µg/dl, while among the rest of the sample it was 7.1 µg/dl (SD=5.1 µg/dl. The presence of a mineral storage area signified a difference in exposure in excess of 13 µg/dl for children living near the port area in contrast to the other children who were not as close to such fixed sources of lead exposure. For the participants in Lima, the risk of showing levels above 10 µg/dl was associated with exposure to high vehicular traffic. CONCLUSIONS: In metropolitan Lima, we conclude that the mean blood lead levels of

  18. Measurements of total lead concentrations and of lead isotope ratios in whole blood by use of inductively coupled plasma source mass spectrometry

    International Nuclear Information System (INIS)

    Delves, H.T.; Campbell, M.J.

    1988-01-01

    Methods are described for the accurate and precise determination of total lead and its isotopic composition in whole blood using inductively coupled plasma source mass spectrometry (ICP-MS). Sensitivities of up to 3 x 10 6 counts s -1 for 208 Pb at a total lead concentration of 5 μmol l -1 (1 μg ml -1 ) enabled total blood lead levels to be measured in 4 min per sample, with a detection limit of 0.072 μmol l -1 (15 μg l -1 ). The agreement between ICP-MS and atomic absorption spectrometry (AAS) for this analysis was excellent: ICP-MS 0.996 x AAS -0.0165 μmol l -1 ; r 0.994. Isotope ratio measurements required 15 min to achieve the required accuracy and precision both of which were generally better than 0.5% for 206 Pb: 207 Pb and 208 Pb: 206 Pb isotopic lead ratios. The ICP-MS data for these ratios in ten quality control blood specimens has a mean bias relative to isotope dilution mass spectrometry of -0.412% for 206 Pb: 207 Pb ratios and of +0.055% for the 208 Pb: 206 Pb ratios. This level of accuracy and that of the total blood lead measurements is sufficient to permit application of these ICP-MS methods to environmental studies. (author)

  19. Determination of Lead in Urine by Atomic Absorption Spectrophotometry1

    Science.gov (United States)

    Selander, Stig; Cramé, Kim

    1968-01-01

    A method for the determination of lead in urine by means of atomic absorption spectrophotometry (AAS) is described. A combination of wet ashing and extraction with ammonium pyrrolidine dithiocarbamate into isobutylmethylketone was used. The sensitivity was about 0·02 μg./ml. for 1% absorption, and the detection limit was about 0·02 μg./ml. with an instrumental setting convenient for routine analyses of urines. Using the scale expansion technique, the detection limit was below 0·01 μg./ml., but it was found easier to determine urinary lead concentrations below 0·05 μg./ml. by concentrating the lead in the organic solvent by increasing the volume of urine or decreasing that of the solvent. The method was applied to fresh urines, stored urines, and to urines, obtained during treatment with chelating agents, of patients with lead poisoning. Urines with added inorganic lead were not used. The results agreed well with those obtained with a colorimetric dithizone extraction method (r = 0·989). The AAS method is somewhat more simple and allows the determination of smaller lead concentrations. PMID:5647975

  20. The use of lead isotope analysis to identify potential sources of lead toxicosis in a juvenile bald eagle (Haliaeetus leucocephalus) with ventricular foreign bodies

    Science.gov (United States)

    Franzen-Klein, Dana; McRuer, David; Slabe, Vincent; Katzner, Todd

    2018-01-01

    A male juvenile bald eagle (Haliaeetus leucocephalus) was admitted to the Wildlife Center of Virginia with a left humeral fracture a large quantity of anthropogenic debris in the ventriculus, a blood lead level of 0.616 ppm, and clinical signs consistent with chronic lead toxicosis. Because of the poor prognosis for recovery and release, the eagle was euthanatized. Lead isotope analysis was performed to identify potential anthropogenic sources of lead in this bird. The lead isotope ratios in the eagle's femur (0.8773), liver (0.8761), and kidneys (0.8686) were most closely related to lead paint (0.8925), leaded gasoline (0.8450), and zinc smelting (0.8240). The lead isotope ratios were dissimilar to lead ammunition (0.8179) and the anthropogenic debris in the ventriculus. This case report documents foreign body ingestion in a free-ranging bald eagle and demonstrates the clinical utility of lead isotope analysis to potentially identify or exclude anthropogenic sources of lead poisoning in wildlife patients.

  1. Urban Airborne Lead: X-Ray Absorption Spectroscopy Establishes Soil as Dominant Source

    OpenAIRE

    Pingitore, Nicholas E.; Clague, Juan W.; Amaya, Maria A.; Maciejewska, Beata; Reynoso, Jes?s J.

    2009-01-01

    BACKGROUND: Despite the dramatic decrease in airborne lead over the past three decades, there are calls for regulatory limits on this potent pediatric neurotoxin lower even than the new (2008) US Environmental Protection Agency standard. To achieve further decreases in airborne lead, what sources would need to be decreased and what costs would ensue? Our aim was to identify and, if possible, quantify the major species (compounds) of lead in recent ambient airborne particulate matter collected...

  2. Determination of material and its thickness for Cs-137 gamma source shielding

    International Nuclear Information System (INIS)

    Tukiman

    2008-01-01

    Its has been determined the shielding material and its thickness necessarily conducted due to every material will have different half-thickness characteristics, and by the selection a suitable material and its thickness will be obtained. Half-thickness of any material is the ability of the material at a certain thickness to absorb any radiation intensity so that the intensity becomes half of its source. Sample materials to be used are concrete, wood, and lead with their thickness varied. From experiment data and theoretical computation can be concluded that lead is the suitable material for shielding with the value of HVT for gamma radiation 0,732 cm. For wood and concrete will give half-thickness of 11,0 cm and 3,164 cm respectively. (author)

  3. Measurement of disintegration rates of small [60Co]Co sources in lead containers by the sum-peak method

    International Nuclear Information System (INIS)

    Kawano, Takao; Ebihara, Hiroshi

    1991-01-01

    The sum-peak method has been applied to determine the disintegration rates of two small [ 60 Co]Co sources (30 and 350 kBq) in lead containers with several thickness by using a NaI(Tl) detector. The experimental results showed that the sum-peak method was perfectly effective for the determination of the disintegration rates (unrelated to the thicknesses of the containers) of the 350 kBq source. The sum-peak method was also absolutely effective for the 30 kBq source in the case of containers with thicknesses of 15 mm and less, but in the cases of those with thicknesses of 21, 27 and 33 mm, the disintegration rates were under-estimated and the deviations from the true disintegration rate increased rapidly with increasing thicknesses of the containers. We presume that the under-estimation of the disintegration rates was the result of the over-estimation of the areas under the sum peaks, caused by the interference of the γ-ray (2614 keV) emitted from the naturally occurring radionuclide 208 Tl. (author)

  4. Experimental apparatus to determine lead attenuation coefficients for photons of 0.511 MeV

    International Nuclear Information System (INIS)

    Vargas, Luis C.B.; Cardoso, Domingos O.; Gavazza, Sérgio; Morales, Rudnei K.; Oliveira, Luciano S. R.

    2017-01-01

    Radioactive gamma-emitting sources with higher energies than 1.022 MeV, may interact with matter by pair production process, generating two photons of 0.511 MeV in the positron annihilation, that may contribute to increase doses in both IOE´s or public. National regulatory agencies require a radiation protection plan and a shielding project to consider the influence of these photons in the licensing procedure. This work will present all steps for the development of the experimental apparatus for determination of the attenuation coefficients for photons with energy of 0.511 MeV in lead. (author)

  5. Determination of Lead and Cadmium in cow’s Milk and Elimination by Using Titanium Dioxide Nanoparticles

    Directory of Open Access Journals (Sweden)

    Haniyeh Moallem Bandani

    2016-10-01

    Full Text Available Background and Objectives: Heavy metals such as cadmium and lead are the most important toxins spreading through various ways like water, soil, and air in nature and easily enter human food chain. It is essential to determine the cumulative and harmful effects of these metals in nutrients, especially in cow milk because it is a unique source of food for all ages and it contains both essential and nonessential trace elements. Materials and Methods: A total of 100 milk samples were directly collected from healthy cows in Zabol located on east of Iran. The samples were tested to determine lead and cadmium residues. The rates of the heavy metals were determined using a Rayleigh atomic absorption spectrum equipped with hollow cathode lamps (HCL at 283.3 nm for lead (Pb and at 228.8 nm for cadmium (Cd. By using the photo-catalytic titanium dioxide nanoparticles, these toxic metals were removed. Results: The mean ± SD of the concentration of lead and cadmium in raw milk were 9.175± 2.5 and 4.557 ± 1.081 ppb, respectively. Also, the P-values of Kalmogorov– Smiranov test for lead and cadmium were respectively 0.057 ppb (P>0.05 and 0.435 ppb (P>0.05. TiO2 nanoparticles were used to eliminate and remove lead and cadmium in milk samples. The results showed that there was a significant difference between lead and cadmium contents before and after adding TiO2 nanoparticles (P<0.05. Conclusions: According to results of this study, there was a very low amount of toxic metals. So, it seems that it is not necessary to use TiO2 in milk samples but these days it used frequently as an additive to some samples like milk to remove these pollutants. Keywords: lead, cadmium, milk, atomic absorption spectroscopy, TiO2 nanoparticles

  6. Lead precipitation fluxes at tropical oceanic sites determined from 210Pb measurements

    International Nuclear Information System (INIS)

    Settle, D.M.; Patterson, C.C.; Turekian, K.K.; Cochran, J.K.

    1982-01-01

    Concentrations of lead, 210 Pb, and 210 Po were measured in rain selected for least influence by local sources of contamination at several tropical and subtropical islands (Enewetak; Pigeon Key, Florida; and American Samoa) and shipboard stations (near Bermuda and Tahiti). Ratios expressed as ng Pb/dpm 210 Pb in rain were 250--900 for Pigeon Key (assuming 12% adsorption for 210 Pb and no adsorption for lead), depending on whether the air masses containing the analyzed rain came from the Caribbean or from the continent, respectively; about 390 for the northern Sargasso Sea downwind from emissions of industrial lead in North America; 65 for Enewetak, remote from continental emissions of industrial lead in the northern hemisphere; and 14 near Tahiti, a remote location in the southern hemisphere where industrial lead emissions to the atmosphere are much less than in the northern hemisphere. (The American Samoa sample yielded a higher ratio than Tahiti; the reason for this is not clear but may be due to local Pb sources). The corresponding fluxes of lead to the oceans, based on measured or modeled 210 Pb precipitation fluxes, are about 4 ng Pb/cm 2 y for Tahiti, 10 for Enewetak, and 270 for the Sargasso Sea site, and between 110 to 390 at Pigeon Key

  7. Isotopic ratio based source apportionment of children's blood lead around coking plant area.

    Science.gov (United States)

    Cao, Suzhen; Duan, Xiaoli; Zhao, Xiuge; Wang, Beibei; Ma, Jin; Fan, Delong; Sun, Chengye; He, Bin; Wei, Fusheng; Jiang, Guibin

    2014-12-01

    Lead exposure in the environment is a major hazard affecting human health, particularly for children. The blood lead levels in the local children living around the largest coking area in China were measured, and the source of blood lead and the main pathways of lead exposure were investigated based on lead isotopic ratios ((207)Pb/(206)Pb and (208)Pb/(206)Pb) in blood and in a variety of media, including food, airborne particulate matter, soil, dust and drinking water. The children's blood lead level was 5.25 (1.59 to 34.36 as range) μg dL(-1), lower than the threshold in the current criteria of China defined by the US Centers for Disease Control (10 μg dL(-1)). The isotopic ratios in the blood were 2.111±0.018 for (208)Pb/(206)Pb and 0.864±0.005 for (207)Pb/(206)Pb, similar to those of vegetables, wheat, drinking water, airborne particulate matter, but different from those of vehicle emission and soil/dust, suggesting that the formers were the main pathway of lead exposure among the children. The exposure pathway analysis based on the isotopic ratios and the human health risk assessment showed that dietary intake of food and drinking water contributed 93.67% of total exposed lead. The study further indicated that the coal used in the coking plant is the dominant pollution source of lead in children's blood. Copyright © 2014 Elsevier Ltd. All rights reserved.

  8. Lead chromate detected as a source of atmospheric Pb and Cr (VI) pollution

    Science.gov (United States)

    Lee, Pyeong-Koo; Yu, Soonyoung; Chang, Hye Jung; Cho, Hye Young; Kang, Min-Ju; Chae, Byung-Gon

    2016-10-01

    Spherical black carbon aggregates were frequently observed in dust dry deposition in Daejeon, Korea. They were tens of micrometers in diameter and presented a mixture of black carbon and several mineral phases. Transmission electron microscopy (TEM) observations with energy-dispersive X-ray spectroscopy (EDS) and selected area diffraction pattern (SADP) analyses confirmed that the aggregates were compact and included significant amounts of lead chromate (PbCrO4). The compositions and morphologies of the nanosized lead chromate particles suggest that they probably originated from traffic paint used in roads and were combined as discrete minerals with black carbon. Based on Pb isotope analysis and air-mass backward trajectories, the dust in Daejeon received a considerable input of anthropogenic pollutants from heavily industrialized Chinese cities, which implies that long-range transported aerosols containing PbCrO4 were a possible source of the lead and hexavalent chromium levels in East Asia. Lead chromate should be considered to be a source of global atmospheric Pb and Cr(VI) pollution, especially given its toxicity.

  9. Lead chromate detected as a source of atmospheric Pb and Cr (VI) pollution.

    Science.gov (United States)

    Lee, Pyeong-Koo; Yu, Soonyoung; Chang, Hye Jung; Cho, Hye Young; Kang, Min-Ju; Chae, Byung-Gon

    2016-10-25

    Spherical black carbon aggregates were frequently observed in dust dry deposition in Daejeon, Korea. They were tens of micrometers in diameter and presented a mixture of black carbon and several mineral phases. Transmission electron microscopy (TEM) observations with energy-dispersive X-ray spectroscopy (EDS) and selected area diffraction pattern (SADP) analyses confirmed that the aggregates were compact and included significant amounts of lead chromate (PbCrO 4 ). The compositions and morphologies of the nanosized lead chromate particles suggest that they probably originated from traffic paint used in roads and were combined as discrete minerals with black carbon. Based on Pb isotope analysis and air-mass backward trajectories, the dust in Daejeon received a considerable input of anthropogenic pollutants from heavily industrialized Chinese cities, which implies that long-range transported aerosols containing PbCrO 4 were a possible source of the lead and hexavalent chromium levels in East Asia. Lead chromate should be considered to be a source of global atmospheric Pb and Cr(VI) pollution, especially given its toxicity.

  10. Atomic absorption spectrometric determination of copper, zinc, and lead in geological materials

    Science.gov (United States)

    Sanzolone, R.F.; Chao, T.T.

    1976-01-01

    An atomic absorption spectrometric method is described for the determination of copper, zinc, and lead in geological materials. The sample is digested with HF-HCl-H2O2; the final solution for analysis is in 10 % (v/v) HCl. Copper and zinc are determined directly by aspirating the solution into an air-acetylene flame. A separate aliquot of the solution is used for determination of lead; lead is extracted into TOPO-MIBK from the acidic solution in the presence of iodide and ascorbic acid. For a 0.50-g sample, the limits of determination are 10-2000 p.p.m. for Cu and Zn, and 5-5000 p.p.m. for Pb. As much as 40 % Fe or Ca. and 10 % Al, Mg, or Mn in the sample do not interfere. The proposed method can be applied to the determination of copper, zinc, and lead in a wide range of geological materials including iron- and manganese-rich, calcareous and carbonate samples. ?? 1976.

  11. Tracing lead pollution sources in abandoned mine areas using stable Pb isotope ratios.

    Science.gov (United States)

    Yoo, Eun-Jin; Lee, Jung-A; Park, Jae-Seon; Lee, Khanghyun; Lee, Won-Seok; Han, Jin-Seok; Choi, Jong-Woo

    2014-02-01

    This study focused on Pb isotope ratios of sediments in areas around an abandoned mine to determine if the ratios can be used as a source tracer. For pretreatment, sediment samples were dissolved with mixed acids, and a multi-collector inductively coupled plasma mass spectrometer (MC-ICP-MS, Nu plasma II) was used to investigate the Pb isotopic composition of the samples. The measured isotope ratios were then corrected for instrumental mass fractionation by measuring the (203)Tl/(205)Tl ratio. Repeated measurements with the NIST SRM 981 reference material showed that the precision of all ratios was below 104 ppm (±2σ) for 50 ng/g. The isotope ratios ((207)Pb/(206)Pb) found were 0.85073 ± 0.0004~0.85373 ± 0.0003 for the main stream, while they were 0.83736 ± 0.0010 for the tributary and 0.84393 ± 0.0002 for the confluence. A binary mixing equation for isotope ratios showed that the contributions of mine lead to neighboring areas were up to 60%. Therefore, Pb isotope ratios can be a good source tracer for areas around abandoned mines.

  12. Determination of cadmium, lead and mercury residual levels in meat ...

    African Journals Online (AJOL)

    Determination of cadmium, lead and mercury residual levels in meat of canned light tuna ( Katsuwonus pelamis and Thunnus albacares ) and fresh little tunny ( Euthynnus alletteratus ) in Libya. ... Surveillance for mercury (Hg), lead (Pb) and cadmium (Cd) contamination in tuna products is crucial for consumer food safety.

  13. Biogeochemical studies of lead isotopes near a smelter

    International Nuclear Information System (INIS)

    Landrigan, P.J.; Baker, E.L. Jr.; Earl, J.L.; Chow, T.J.

    1975-01-01

    Ninety-nine percent of 1 to 9 year-old children living within 1 mile of a primary lead smelter in Idaho were found to have whole blood lead levels equal to or greater than 40μg/100 ml, a level indicative of excess lead absorption. To define the sources of this lead, isotope ratios were determined in lead from human and environmental samples obtained near the smelter; determinations were performed using a 30-cm radius, solid-source mass spectrometer with an electron multiplier. The Idaho ore is a pre-Cambrian lead deposit with 206 Pb/ 204 Pb = 16.43, 206 Pb = 1.0543 and 206 Pb/ 208 Pb = 0.4518. An ingot smelted in 1974 showed isotope ratios of 206 Pb/ 204 Pb = 17.66, 206 Pb/ 207 Pb = 1.1312 and 206 Pb/ 208 Pb = 0.4694, indicating a mixture of ore sources. Three surface soil samples from within 2 miles of the smelter had lead ratios similar to those in the ingot. A fourth soil sample from beside an interstate highway 32 miles east of the smelter showed different ratios: 206 Pb/ 204 Pb = 18.47, 206 Pb/ 207 Pb = 1.1826 and 206 Pb/ 208 Pb = 0.4823. Aerosol samples collected from October 4, 1974, to February 1, 1975, near the smelter showed considerable variation in ratios; these variations resulted from smelting of ores from differing sources

  14. Determination of Airborne Lead Contamination in Cichorium intybus L. in an Urban Environment

    OpenAIRE

    YAKUPOĞLU, Dilmaç; GÜRAY, Tülin; SARICA, Deniz YURTSEVER; KAYA, Zeki

    2014-01-01

    The major source of environmental lead (Pb) is the combustion of leaded gasoline. After emission as exhaust, lead in the air falls to earth and contaminates soil and plants. Seventeen wild chicory (Cichorium intybus L.) plant samples were collected from each of 2 urban sites in Ankara, one is located at the road side of major intercity road (heavy traffic) and the other one is located in relatively less traffic area that is about 1 km away from the first location. Lead content of chicory plan...

  15. Instrumental neutron-activation determination of impurities in lead and titanium compounds

    Energy Technology Data Exchange (ETDEWEB)

    Popova, I L

    1980-01-01

    Instrumental neutron-activation analysis was used to determine 22 impurities in lead and titanium compounds (e.g. PbO, Pb/NO3/2, and TiO2) used as raw materials for ferroelectrics. Five elements (Al, V, Mn, Sc, and Se) were determined by short-lived isotopes and 17 elements were determined by long-lived isotopes. The detection limits were 7 x 10 to the -3rd to 2 x 10 to the -8th %. A substantial difference in concentrations of certain impurity elements has been found in different series of lead and titanium oxides of similar purity.

  16. Two Functionally Distinct Sources of Actin Monomers Supply the Leading Edge of Lamellipodia

    Science.gov (United States)

    Vitriol, Eric A.; McMillen, Laura M.; Kapustina, Maryna; Gomez, Shawn M.; Vavylonis, Dimitrios; Zheng, James Q.

    2015-01-01

    Summary Lamellipodia, the sheet-like protrusions of motile cells, consist of networks of actin filaments (F-actin) regulated by the ordered assembly from and disassembly into actin monomers (G-actin). Traditionally, G-actin is thought to exist as a homogeneous pool. Here, we show that there are two functionally and molecularly distinct sources of G-actin that supply lamellipodial actin networks. G-actin originating from the cytosolic pool requires the monomer binding protein thymosin β4 (Tβ4) for optimal leading edge localization, is targeted to formins, and is responsible for creating an elevated G/F-actin ratio that promotes membrane protrusion. The second source of G-actin comes from recycled lamellipodia F-actin. Recycling occurs independently of Tβ4 and appears to regulate lamellipodia homeostasis. Tβ4-bound G-actin specifically localizes to the leading edge because it doesn’t interact with Arp2/3-mediated polymerization sites found throughout the lamellipodia. These findings demonstrate that actin networks can be constructed from multiple sources of monomers with discrete spatiotemporal functions. PMID:25865895

  17. Heavy element concentration determination by the x-ray fluorescence analysis using radioisotope {gamma}-ray sources; Dosage d'elements lourds par fluorescence X utilisant des radio-sources de rayons gamma

    Energy Technology Data Exchange (ETDEWEB)

    Enomoto, S [Commissariat a l' Energie Atomique, Dir. des Materiaux et des Combustibles Nucleaires, Saclay (France). Centre d' Etudes Nucleaires

    1968-07-01

    A theoretical and experimental study has been made on the fluorescence analysis of high atomic number element, using {gamma}-ray sources for excitation and characteristic K X-rays for the measurement. The choice of the proper {gamma}-ray energy according to the conditions of the determination is considered. The author has studied the usefulness of using the backscattered {gamma}-rays as a correction mean for matrix and grain-size effects. Sources of {sup 153}Gd, {sup 57}Co, {sup 137}Cs have been used for excitation using collimated geometries. Concentration measurements of tungsten in steel, tungsten and lead in aqueous solution, PbS in SiO{sub 2}-PbS powder mixtures have been done, as well as thickness evaluation of gold layers on copper. A precision of about 0.2 per cent (abs.) is obtained for lead determination in light matrixes. A probe design is proposed for the continuous determination of lead in aqueous solutions. (author) [French] On etudie de maniere theorique et experimentale l'analyse d'elements a nombre atomique eleve par fluorescence en utilisant des sources de rayons {gamma} pour l'excitation, et des rayons-X K caracteristiques pour la mesure. On considere le choix de l'energie appropriee des rayons {gamma} suivant les conditions experimentales. L'utilite d'employer les rayons {gamma} retrodiffuses pour corriger les effets de la matrice et de la dimension des grains est etudiee. Des sources de {sup 153}Gd, de {sup 57}Co et de {sup 137}Cs a geometrie collimatee ont ete utilisees pour l'excitation. Des mesures de la concentration du tungstene dans l'acier, du tungstene et du plomb en solutions aqueuses, et du PbS dans des melanges de poudre SiO{sub 2}-PbS ont ete entreprises ainsi que l'evaluation de l'epaisseur des couches d'or sur le cuivre. On obtient une precision d'environ 0,2 pour cent (en absolu) pour la determination du plomb dans des matrices legeres. On propose un modele de sonde pour la determination en continu du plomb en solution aqueuse

  18. Levels and sources of particulate lead in air at Kwabenya, Accra, Ghana

    International Nuclear Information System (INIS)

    Ofosu, F.G.; Aboh, I.J.K.

    2008-01-01

    The Government of Ghana by Legislation Instrument L.I 1732 banned the production, importation, storage, sale and use of leaded gasoline in Ghana with effect from 1 st January 2004. The aim of this work is to find out the contribution of lead to the atmospheric aerosol two years after the coming into force of the ban. The sampling was done using a Gent sampler with stacked filter units and the aerosol collected size fractionated into PM 2.5 (fine) and PM 10-2.5 (Coarse). Energy dispersive x-ray fluorescence (EDXRF) analysis was used to identify and quantify lead (Pb) and other elements in both the coarse and fine fractions. The average concentration of Pb in the ambient air was 1.49 ngm -3 and 0.70 ngm -3 for the coarse and fine fractions respectively. The average total of both the coarse and fine fractions (which is PM 10 ) was 2.19 ngm -3 , which is well below the US EPA set standard of 1.5 μgm -3 . Source apportionment on the fine fraction using Principal Component Analysis (PCA) showed that mostly soil/dust and to a lesser extent combustion processes were the sources of the Pb. (au)

  19. Determination of lead and radioactivity in cosmetics products: Hazard assessment

    Directory of Open Access Journals (Sweden)

    Medhat Moustafa E.

    2015-01-01

    Full Text Available In the proposed work, an investigation on hazard assessment by lead element and natural radioactivity in cosmetic samples collected from various countries is presented. These samples were face powder, eyebrow paint and henna. The lead element in cosmetic samples was determined using particle-induced X-ray emission. Maximum natural radioactivity concentrations of 226Ra and 40K were found in khol and make-up cosmetic samples, respectively. The qualitative analysis of cosmetic samples showed that lead is the most toxic element found in eyebrow paint samples.

  20. Iodide-assisted total lead measurement and determination of different lead fractions in drinking water samples.

    Science.gov (United States)

    Zhang, Yuanyuan; Ng, Ding-Quan; Lin, Yi-Pin

    2012-07-01

    Lead and its compounds are toxic and can harm human health, especially the intelligence development in children. Accurate measurement of total lead present in drinking water is crucial in determining the extent of lead contamination and human exposure due to drinking water consumption. The USEPA method for total lead measurement (no. 200.8) is often used to analyze lead levels in drinking water. However, in the presence of high concentration of the tetravalent lead corrosion product PbO(2), the USEPA method was not able to fully recover particulate lead due to incomplete dissolution of PbO(2) particles during strong acid digestion. In this study, a new procedure that integrates membrane separation, iodometric PbO(2) measurement, strong acid digestion and ICP-MS measurement was proposed and evaluated for accurate total lead measurement and quantification of different lead fractions including soluble Pb(2+), particulate Pb(II) carbonate and PbO(2) in drinking water samples. The proposed procedure was evaluated using drinking water reconstituted with spiked Pb(2+), spiked particulate Pb(II) carbonate and in situ formed or spiked PbO(2). Recovery tests showed that the proposed procedure and the USEPA method can achieve 93-112% and 86-103% recoveries respectively for samples containing low PbO(2) concentrations (0.018-0.076 mg Pb per L). For samples containing higher concentrations of PbO(2) (0.089-1.316 mg Pb per L), the USEPA method failed to meet the recovery requirement for total lead (85-115%) while the proposed method can achieve satisfactory recoveries (91-111%) and differentiate the soluble Pb(2+), particulate Pb(II) carbonate and PbO(2).

  1. Determining Childhood Blood Lead Level Screening Compliance Among Physicians.

    Science.gov (United States)

    Haboush-Deloye, Amanda; Marquez, Erika R; Gerstenberger, Shawn L

    2017-08-01

    Childhood Lead Poisoning Prevention Programs throughout the U.S. have addressed childhood lead poisoning by implementing primary and secondary prevention efforts. While many programs have helped increase screening rates, in some states children under the age of six still have not been tested for lead. This study aims to identify the barriers to childhood blood lead testing and develop a strategy to increase the number of children tested. Clark County physicians who work with children six and under were surveyed about blood lead level (BLL) testing practices, particularly, adherence to Centers for Disease Control and Prevention (CDC) guidelines, and parental compliance with orders to have their children tested to determine their blood lead levels. In addition, select in-person interviews were conducted with physicians who reported high parental compliance to identify best practices and barriers. Of the 77 physicians that provided data, 48% indicated they did not follow CDC guideline compared to 52% who follow guidelines. 18 of the 30 (or 60%) physicians reported more than 80% of parents complied with doctor recommended BLL testing. Twelve physicians identified cost, lack of insurance, and absence of symptomology as persistent barriers to lead screening. This study identified barriers to childhood lead screening including inadequate parental adherence to physician-ordered screenings and physician non-compliance with screening recommendations are two primary contributors. Addressing these issues could increase screening in children and reduce the risk of lead poisoning.

  2. Determination of Lead in Blood by Atomic Absorption Spectrophotometry1

    Science.gov (United States)

    Selander, Stig; Cramér, Kim

    1968-01-01

    Lead in blood was determined by atomic absorption spectrophotometry, using a wet ashing procedure and a procedure in which the proteins were precipitated with trichloroacetic acid. In both methods the lead was extracted into isobutylmethylketone before measurement, using ammonium pyrrolidine dithiocarbamate as chelator. The simpler precipitation procedure was shown to give results identical with those obtained with the ashing technique. In addition, blood specimens were examined by the precipitation method and by spectral analysis, which method includes wet ashing of the samples, with good agreement. All analyses were done on blood samples from `normal' persons or from lead-exposed workers, and no additions of inorganic lead were made. The relatively simple protein precipitation technique gave accurate results and is suitable for the large-scale control of lead-exposed workers. PMID:5663425

  3. Determination of lead in mother's milk by atomic absorption spectroscopy

    International Nuclear Information System (INIS)

    Bandarchian, F.; Assadian, F

    2002-01-01

    With due attention to increasing air pollution specially the lead amount that is generated from gasoline burning in automobiles, it seems that it is necessary to control the amount of it continuously. Because Pb has an easy absorbability to body and also damages the nervous system. For this reason determination of it in mother's milk has a special importance. In this research, the milks of 15 mothers twice a day were examined and the concentration of Pb were determined by atomic absorption spectroscopy. In accordance the international organization, the permissible amount in body is 0.05 ppm. Fortunately, the obtained data was less than of it and it showed the absorbance of lead by babies is insignificant

  4. Determination of Pb (Lead, Cd (Cadmium, Cr (Chromium, Cu (Copper, and Ni (Nickel in Chinese tea with high-resolution continuum source graphite furnace atomic absorption spectrometry

    Directory of Open Access Journals (Sweden)

    Wen-Si Zhong

    2016-01-01

    Full Text Available The contents of lead, cadmium, chromium, copper, and nickel were determined in 25 tea samples from China, including green, yellow, white, oolong, black, Pu'er, and jasmine tea products, using high-resolution continuum source graphite furnace atomic absorption spectrometry. The methods used for sample preparation, digestion, and quantificational analysis were established, generating satisfactory analytical precisions (represented by relative standard deviations ranging from 0.6% to 2.5% and recoveries (98.91–101.32%. The lead contents in tea leaves were 0.48–10.57 mg/kg, and 80% of these values were below the maximum values stated by the guidelines in China. The contents of cadmium and chromium ranged from 0.01 mg/kg to 0.39 mg/kg and from 0.27 mg/kg to 2.45 mg/kg, respectively, remaining in compliance with the limits stipulated by China's Ministry of Agriculture. The copper contents were 7.73–63.71 mg/kg; only 64% of these values complied with the standards stipulated by the Ministry of Agriculture. The nickel contents ranged from 2.70 mg/kg to 13.41 mg/kg. Consequently, more attention must be paid to the risks of heavy metal contamination in tea. The quantitative method established in this work lays a foundation for preventing heavy metal toxicity in human from drinking tea and will help establish regulations to control the contents of heavy metals in tea.

  5. Determining lead sources in Mexico using the lead isotope ratio La identificación de fuentes de exposición a plomo en México a través de la determinación de la razón de isótopos de plomo

    Directory of Open Access Journals (Sweden)

    Madhu Chaudhary-Webb

    2003-01-01

    Full Text Available OBJECTIVE: Lead poisoning can, in some cases, be traced to a specific route or source of exposure on the basis of the individual's blood lead isotope ratio. To assess the major source of lead exposure among women residing in Mexico City, we compared blood, ceramic, and gasoline lead isotope ratios. MATERIAL AND METHODS: The study population, randomly selected from participants of a large trial, (1/1996-12/1996 comprised of 16 women whose lead levels exceeded 10 µg/dl and who reported using lead-glazed ceramics. Lead isotope ratios were performed on a Perkin Elmer 5000 Inductively Coupled Plasma Mass Spectrometer (ICP-MS interfaced with a Perkin Elmer HGA-600MS Electrothermal Vaporization System (ETV. RESULTS: The isotope ratios (206Pb/204Pb, 207Pb/204Pb, and 208Pb/204Pb of both the blood specimens and their corresponding ceramic specimens were highly correlated, with r=0.9979, r²=0.9958, r=0.9957, r²=0.9915 and r=0.9945, r²=0.9890 values for the three isotope ratios, respectively, suggesting that the lead exposure most likely resulted from the use of these ceramic. Measurements of lead isotope ratios from leaded gasoline in use at the time of blood sampling, differed from those in blood and ceramics. CONCLUSIONS: Determining lead isotope ratios can be an efficient tool to identify a major source of lead exposure and to support the implementation of public health prevention and control measures.OBJETIVO: Identificar la fuente principal de exposición a plomo entre mujeres residentes en la Ciudad de México, por medio de la comparación de las razones de isótopos de plomo en sangre, cerámica y gasolina. MATERIAL Y MÉTODOS: La población de estudio fue seleccionada aleatoriamente de participantes de una muestra obtenida de enero a diciembre de 1996 y consistió en 16 mujeres con niveles de plomo mayores a 10 µg/dl, que usaban cerámica vidriada con plomo. Las razones de isótopos de plomo se obtuvieron con un espectrómetro de masa de

  6. Strategic Sourcing of R&D: The Determinants of Success

    Science.gov (United States)

    Brook, Jacques W.; Plugge, Albert

    The outsourcing of the R&D function is an emerging practice of corporate firms. In their attempt to reduce the increasing cost of research and technology development, firms are strategically outsourcing the R&D function or repositioning their internal R&D organisation. By doing so, they are able to benefit from other technology sources around the world. So far, there is only limited research on how firms develop their R&D sourcing strategies and how these strategies are implemented. This study aims to identify which determinants contribute to the success of R&D sourcing strategies. The results of our empirical research indicate that a clear vision of how to manage innovation strategically on a corporate level is a determinant of an effective R&D strategy. Moreover, our findings revealed that the R&D sourcing strategy influences a firm's sourcing capabilities. These sourcing capabilities need to be developed to manage the demand as well as the supply of R&D services. The alignment between the demand capabilities and the supply capabilities contributes to the success of R&D sourcing.

  7. Surface dust wipes are the best predictors of blood leads in young children with elevated blood lead levels

    Energy Technology Data Exchange (ETDEWEB)

    Gulson, Brian, E-mail: brian.gulson@mq.edu.au [Graduate School of the Environment, Macquarie University, North Ryde NSW 2109 (Australia); CSIRO Earth Science and Resource Engineering, North Ryde NSW 2113 (Australia); Anderson, Phil [Information and Statistics Group, Australian Institute of Health and Welfare, Canberra ACT 2601 (Australia); Faculty of Health, University of Canberra, Canberra ACT 2601 (Australia); Taylor, Alan [Department of Psychology, Macquarie University, Sydney NSW 2109 (Australia)

    2013-10-15

    Background: As part of the only national survey of lead in Australian children, which was undertaken in 1996, lead isotopic and lead concentration measurements were obtained from children from 24 dwellings whose blood lead levels were ≥15 µg/dL in an attempt to determine the source(s) of their elevated blood lead. Comparisons were made with data for six children with lower blood lead levels (<10 µg/dL). Methods: Thermal ionisation and isotope dilution mass spectrometry were used to determine high precision lead isotopic ratios ({sup 208}Pb/{sup 206}Pb, {sup 207}Pb/{sup 206}Pb and {sup 206}Pb/{sup 204}Pb) and lead concentrations in blood, dust from floor wipes, soil, drinking water and paint (where available). Evaluation of associations between blood and the environmental samples was based on the analysis of individual cases, and Pearson correlations and multiple regression analyses based on the whole dataset. Results and discussion: The correlations showed an association for isotopic ratios in blood and wipes (r=0.52, 95% CI 0.19–0.74), blood and soil (r=0.33, 95% CI −0.05–0.62), and blood and paint (r=0.56, 95% CI 0.09–0.83). The regression analyses indicated that the only statistically significant relationship for blood isotopic ratios was with dust wipes (B=0.65, 95% CI 0.35–0.95); there were no significant associations for lead concentrations in blood and environmental samples. There is a strong isotopic correlation of soils and house dust (r=0.53, 95% CI 0.20–0.75) indicative of a common source(s) for lead in soil and house dust. In contrast, as with the regression analyses, no such association is present for bulk lead concentrations (r=−0.003, 95% CI −0.37–0.36), the most common approach employed in source investigations. In evaluation of the isotopic results on a case by case basis, the strongest associations were for dust wipes and blood. -- Highlights: • Children with elevated blood lead ≥15 µg/dL compared with a group with <10

  8. Apparatus for radiation source depth determination in a material

    International Nuclear Information System (INIS)

    Campbell, P.J.

    1979-01-01

    An apparatus is disclosed for determining the depth of a radiation source within a body of material utilizing a radiation source holder moving the radiation source within the body. A plurality of switches have contacts that are fixed in relation to the movement of the radiation source within the material. Trigger means activates a particular switch at a preselected depth of the radiation source. Means for indicating the activation of a switch would thus produce a signal as a representative of the depth of the radiation source

  9. Lead induced dyslipidemia: The comparative effects of ascorbate ...

    African Journals Online (AJOL)

    R.N. UGBAJA

    2013-04-10

    Apr 10, 2013 ... metabolism in lead exposed rats, 35 male Wistar rats were used. They were grouped ... The blood lipid profiles were determined spectrophotometrically. Lead exposure ... Other significant sources include cosmetic products, food-can .... duplicates using a Thermo Scientific S Series Atomic Absorption.

  10. Lead concentration distribution and source tracing of urban/suburban aquatic sediments in two typical famous tourist cities: Haikou and Sanya, China.

    Science.gov (United States)

    Dong, Zhicheng; Bao, Zhengyu; Wu, Guoai; Fu, Yangrong; Yang, Yi

    2010-11-01

    The content and spatial distribution of lead in the aquatic systems in two Chinese tropical cities in Hainan province (Haikou and Sanyan) show an unequal distribution of lead between the urban and the suburban areas. The lead content is significantly higher (72.3 mg/kg) in the urban area than the suburbs (15.0 mg/kg) in Haikou, but quite equal in Sanya (41.6 and 43.9 mg/kg). The frequency distribution histograms suggest that the lead in Haikou and in Sanya derives from different natural and/or anthropogenic sources. The isotopic compositions indicate that urban sediment lead in Haikou originates mainly from anthropogenic sources (automobile exhaust, atmospheric deposition, etc.) which contribute much more than the natural sources, while natural lead (basalt and sea sands) is still dominant in the suburban areas in Haikou. In Sanya, the primary source is natural (soils and sea sands).

  11. Use of Pb and Sr isotopes on the determination of lead mineralization sources from Ribeira valley - Sao Paulo and Parana states

    International Nuclear Information System (INIS)

    Tassinari, C.C.G.; Barbour, A.P.; Sato, K.; Daitx, E.C.

    1990-01-01

    A lead and strontium isotope study was carried out on galena, barite and calcite from Pb-Ag syngenetic stratiform (Perau type) and hydrothermal veins (Panela type) deposits from Vale do Ribeira region (Sao Paulo and Parana states). The leads from the Perau and Panelas type deposits have respectively isotope ratios (sup(206)Pb/ sup(204)Pb 16.157 to 16.505 amd 16.520 to 17.273; sup(207)Pb/ sup(204)Pb = 15.466 to 15.720 and 15.470 to 15.780 and sup(208)Pb/ sup(204)Pb = 36.370 to 36.763 and 37.043 to 38.243), that defined a Stacey and Kramers model ages mainly concentrate within 1.7-1.5Ga. A review of published Pb isotopic compositions for these deposits and considerations of new Sr isotope data and Pb results using plumbotectonics model, indicate that the Perau type mineralizations are related to the syngenetic process and the Pb are derived from upper crust with a short crustal residence time. For the Panelas type deposits the Pb and Sr isotope studies support the conclusion that the ores were emplaced during regional metamorphism and the Pb were derived from lithologically complex source which may include metasedimentary and basement rocks. (author)

  12. Isotopic identification of natural vs. anthropogenic lead sources in marine sediments from the inner Ria de Vigo (NW Spain)

    Energy Technology Data Exchange (ETDEWEB)

    Alvarez-Iglesias, P., E-mail: palvarez@uvigo.es [Department of Marine Geosciences and Land Use Management, Faculty of Marine Sciences, University of Vigo (Spain); Laboratorio de Analisis Quimico Instrumental, C.A.C.T.I., Universidad de Vigo (Spain); Rubio, B., E-mail: brubio@uvigo.es [Department of Marine Geosciences and Land Use Management, Faculty of Marine Sciences, University of Vigo (Spain); Millos, J., E-mail: jmillos@uvigo.es [Laboratorio de Analisis Quimico Instrumental, C.A.C.T.I., Universidad de Vigo (Spain)

    2012-10-15

    San Simon Bay, the inner part of the Ria de Vigo (NW Spain), an area previously identified as highly polluted by Pb, was selected for the application of Pb stable isotope ratios as a fingerprinting tool in subtidal and intertidal sediment cores. Lead isotopic ratios were determined by inductively coupled plasma mass spectrometry on extracts from bulk samples after total acid digestion. Depth-wise profiles of {sup 206}Pb/{sup 207}Pb, {sup 206}Pb/{sup 204}Pb, {sup 207}Pb/{sup 204}Pb, {sup 208}Pb/{sup 204}Pb and {sup 208}Pb/{sup 207}Pb ratios showed, in general, an upward decrease for both intertidal and subtidal sediments as a consequence of the anthropogenic activities over the last century, or centuries. Waste channel samples from a nearby ceramic factory showed characteristic Pb stable isotope ratios different from those typical of coal and petrol. Natural isotope ratios from non-polluted samples were established for the study area, differentiating sediments from granitic or schist-gneiss sources. A binary mixing model employed on the polluted samples allowed estimating the anthropogenic inputs to the bay. These inputs represented between 25 and 98% of Pb inputs in intertidal samples, and 9-84% in subtidal samples, their contributions varying with time. Anthropogenic sources were apportioned according to a three-source model. Coal combustion-related emissions were the main anthropogenic source Pb to the bay (60-70%) before the establishment of the ceramic factory in the area (in the 1970s) which has since constituted the main source (95-100%), followed by petrol-related emissions. The Pb inputs history for the intertidal area was determined for the 20th century, and, for the subtidal area, the 19th and 20th centuries. -- Highlights: Black-Right-Pointing-Pointer Pb stable isotope ratios were applied to study Pb sources in coastal sediments. Black-Right-Pointing-Pointer Pb isotopic ratios were determined for pre-pollution and for industrial samples. Black

  13. Lead isotope ratios in lichen samples evaluated by ICP-ToF-MS to assess possible atmospheric pollution sources in Havana, Cuba.

    Science.gov (United States)

    Alvarez, Alfredo Montero; Estévez Alvarez, Juan R; do Nascimento, Clístenes Williams Araújo; González, Iván Pupo; Rizo, Oscar Díaz; Carzola, Lázaro Lima; Torres, Roberto Ayllón; Pascual, Jorge Gómez

    2017-01-01

    Epiphytic lichens, collected from 119 sampling sites grown over "Roistonea Royal Palm" trees, were used to assess the spatial distribution pattern of lead (Pb) and identify possible pollution sources in Havana (Cuba). Lead concentrations in lichens and topsoils were determined by flame atomic absorption spectrophotometry and inductively coupled plasma (ICP) atomic emission spectrometry, respectively, while Pb in crude oils and gasoline samples were measured by ICP-time of flight mass spectrometry (ICP-ToF-MS). Lead isotopic ratios measurements for lichens, soils, and crude oils were obtained by ICP-ToF-MS. We found that enrichment factors (EF) reflected a moderate contamination for 71% of the samples (EF > 10). The 206 Pb/ 207 Pb ratio values for lichens ranged from 1.17 to 1.20 and were a mixture of natural radiogenic and industrial activities (e.g., crude oils and fire plants). The low concentration of Pb found in gasoline (leaded gasoline is no longer used in Cuba.

  14. Lead pollution and its sources along the Turkish coast of the Black Sea

    Directory of Open Access Journals (Sweden)

    M. UNSAL

    2001-12-01

    Full Text Available Lead pollution and its sources have been investigated in the south-eastern and south-western Black Sea. Surficial sediments and mussels were collected in different seasons of the year from the south-eastern and south-western Black Sea and analysed for their lead contents. In the south-eastern Black Sea sediments from the easternmost and from the central stations contained the highest lead concentrations. Sediments contained 8 to 10 times the lead concentrations of sediments from the south-west. Samples taken from rivers, streams and effluents had especially high lead concentrations. The highest lead concentrations were found in sediments collected in October and December. Lead concentrations in mussels from the south-eastern coast were comparatively lower compared to those from the south-western coast. The highest average values occurred in December and in October. In the south-western Black Sea, the highest lead concentrations in sediments were obtained in those from Inebolu, followed by those from around Zonguldak. The concentrations increased from the middle to the west of the southern Black Sea coast, possibly due to the effect of the Danube River. Sediments taken in September had the highest lead concentrations, followed by samples taken in December. Very high lead concentrations (> 10 μ g g-1 were observed in mussels from those stations where the sediments also contained high concentrations. Mussels had their highest lead concentrations in January and April.

  15. Tracing toxic elements sources using lead isotopes: An example from the San Antonio–El Triunfo mining district, Baja California Sur, México

    International Nuclear Information System (INIS)

    Gutiérrez-Caminero, Leopoldo; Weber, Bodo; Wurl, Jobst; Carrera-Muñoz, Mariela

    2015-01-01

    Highlights: • Provenance of toxic elements is investigated in a basin close to the mining district. • Stable lead isotope analyses assist to distinguish between sources of toxic elements. • Two major sources are identified: mine tailings and fault bounded mineralization. • There is evidence in the detritus of a different natural lead component. • An additional anthropogenic lead input is detectable from the soluble phases. - Abstract: Pollution of sediments and water bodies with toxic elements around the San Antonio–El Triunfo mining district, Baja California Sur, México is probably sourced from the tailings of abandoned mines that are hosted in mineralized Cretaceous granitoids. However, there is evidence to suggest local hot springs related to recent faults may be an additional source for contamination in the area. In this study, lead isotope signatures are applied to draw conclusions with regard to potential sources of toxic elements. Lead isotope ratios were analyzed from sulfides and scoria from the abandoned mines, fluvial sediments, and igneous rocks with secondary disseminated mineralization. To differentiate between superposed secondary and residual primary lead, leaching experiments were performed, and both leachate and residues were analyzed separately. Most of the residues from sediment samples have lead isotope ratios similar to those from the sulfides and scoria of the mining district, indicating that most of the lead in the detritus is related to the mineralized plutons. However, there is evidence of an additional detrital component. Lead isotope ratios from the leachates indicate a different source for the superimposed lead that is best explained by the contamination with the average Mexican industrial lead. Secondary disseminated mineralization that is related to younger, deep structures (hot springs) has different lead isotope ratios compared to massive vein sulfides and accounts for a significant amount in areas with high

  16. [Environmental lead poisoning from lead-glazed earthenware used for storing drinks].

    Science.gov (United States)

    Sabouraud, S; Coppéré, B; Rousseau, C; Testud, F; Pulce, C; Tholly, F; Blanc, M; Culoma, F; Facchin, A; Ninet, J; Chambon, P; Medina, B; Descotes, J

    2009-12-01

    Current unusual environmental sources of lead exposure mainly include traditional medicines, either ayurvedic remedies or others, traditional cosmetics (kohl, surma), and the use of traditional earthenware, for storage or cooking. We report two cases of lead poisoning in adults initially identified by paroxysmal abdominal pain or anemia. In both cases, the environmental investigation evidenced one main source of lead exposure, namely a lead-glazed earthenware jug in which a drink was stored, "kefir" in the first case, and "kombucha" tea in the second one. It is recommended to search for lead intoxication in patients with unexplained anemia. Environmental sources of lead can be multiple. Their relative importance has to be ranked during the environmental investigation and among these, lead-glazed earthenware must be considered as a source of high lead exposure when drinks are stored inside and thus can soak.

  17. Lead contents in blood samples of a children population of Mexico City related to levels of airborne lead determined by PIXE

    International Nuclear Information System (INIS)

    Uribe-Hernandez, R.; Perez-Zapata, A.J.; Flores M., J.; Aldape, F.; Hernandez-Mendez, B.

    1996-01-01

    Airborne lead has been considered for many years one of the main pollutants adversely affecting the health of human beings. Moreover, this problem becomes remarkably important in large urban areas such as Mexico City. In order to assess the influence of atmospheric airborne lead in a children population, a biological blood sampling was carried out from September 1992 to June 1993 taking 698 samples in children with ages ranging from a few weeks to thirteen years old. Lead contents in whole blood were determined using anode stripping voltammetry as analytical technique. At the same time, aerosol lead contents were determined by PIXE from samples taken twice a week (two samples per day) in a neighbour area. In 58% of the samples, lead contents in blood was found over the maximum permissible level established by the Center for Disease Control (CDC) of the U.S.A. The biological sampling was correlated to levels of airborne lead as well as children age and date of sampling. General results of these comparisons are presented. (author)

  18. Radiation studies in the antiproton source

    International Nuclear Information System (INIS)

    Church, M.

    1990-01-01

    Experiment E760 has a lead glass (Pb-G) calorimeter situated in the antiproton source tunnel in the accumulator ring at location A50. This location is exposed to radiation from several sources during antiproton stacking operations. A series of radiation studies has been performed over the last two years to determine the sources of this radiation and as a result, some shielding has been installed in the antiproton source in order to protect the lead glass from radiation damage

  19. Determination of tellurium in lead and lead alloy using flow injection-hydride generation atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Mesko, Marcia F.; Pozebon, Dirce; Flores, Erico M.M.; Dressler, Valderi L.

    2004-01-01

    A method based on flow injection-hydride generation atomic absorption spectrometry (FI-HG AAS) for the determination of trace amount of Te in lead and lead alloy is described. A flow injection system (FI) and related analytical parameters as well as Te determination and interference caused by Pb, Bi and Ag on Te were investigated. The Pb interference could be overcome by using a small sample volume, while the Bi interference could be overcome by thiourea. However, it was not possible to minimise the interference caused by Ag on Te. The optimised conditions for Te determination in the analysed samples were: 6 mol l -1 HCl as sample carrier solution, 0.75% (m/v) sodium tetrahydroborate as Te reductant, 40 μl of sample solution, and 200 ml min -1 Ar flow rate as carrier gas. The limit of quantification (LOQ) was 1.0 μg g -1 Te (using 250 mg of sample in 50 ml final solution), the limit of detection (LOD) was 2.5 μg l -1 and the relative standard deviation (RSD) was 6% for five consecutive measurements of sample solution. The standard addition calibration method was used. Relatively high sample throughput (ca. 45 sample runs can be performed in a working hour), reduced sample manipulation since matrix separation is not necessary, and minor waste generation are the main advantages of the proposed method for Te determination by FI-HG AAS

  20. Limitations of absolute activity determination of I-125 sources

    Energy Technology Data Exchange (ETDEWEB)

    Pelled, O; German, U; Kol, R; Levinson, S; Weinstein, M; Laichter, Y [Israel Atomic Energy Commission, Beersheba (Israel). Nuclear Research Center-Negev; Alphasy, Z [Ben-Gurion Univ. of the Negev, Beersheba (Israel)

    1996-12-01

    A method for absolute determination of the activity of a I-125 source, based on the counting rate values of the 27 keV photons and the coincidence photon peak is given in the literature. It is based on the principle that if a radionuclide emits two photons in coincidence , a measurement of its disintegration rate in the photopeak and in the sum- peak can determinate it`s absolute activity. When using this method , the system calibration is simplified and parameters such as source geometry or source position relative to the detector have no significant influence. However, when the coincidence rate is very low, the application of this method is limited because of the statistics of the coincidence peak (authors).

  1. Lead contamination in Eugenia dyeriana herbal preparations from different commercial sources in Malaysia.

    Science.gov (United States)

    Ang, H H

    2008-06-01

    The Drug Control Authority (DCA) of Malaysia implemented the phase three registration of traditional medicines on 1 January, 1992. A total of 100 products in various pharmaceutical dosage forms of a herbal preparation, containing Eugenia dyeriana, either single or combined preparations (more than one medicinal plant), were analyzed for the presence of lead contamination, using atomic absorption spectrophotometry. These samples were bought from different commercial sources in the Malaysian market, after performing a simple random sampling. Results showed that 22% of the above products failed to comply with the quality requirement for traditional medicines in Malaysia. Although this study showed that 78% of the products fully complied with the quality requirement for traditional medicines in Malaysia pertaining to lead, however, they cannot be assumed safe from lead contamination because of batch-to-batch inconsistency.

  2. Occurrence and determinants of increases in blood lead levels in children shortly after lead hazard control activities

    International Nuclear Information System (INIS)

    Clark, Scott; Grote, JoAnn; Wilson, Jonathan; Succop, Paul; Chen Mei; Galke, Warren; McLaine, Pat

    2004-01-01

    This study is an examination of the effect of lead hazard control strategies on children's blood lead levels immediately after an intervention was conducted as part of the US Department of Housing and Urban Development's Lead-Based Paint Hazard Control Grant Program. Fourteen state and local government grantees participated in the evaluation. The findings indicated an overall average reduction in the blood lead levels of 869 children soon after the implementation of lead hazard controls. However, 9.3% of these children (n=81) had blood lead increases of 5 μg/dL or more. Data routinely collected as part of the evaluation, as well as additional information supplied by the individual programs, were used to determine potential reasons for these observed increases in blood lead. A logistic regression analysis indicated that three principal factors were associated with the blood lead increases: the number of exterior deteriorations present in the child's home (prior to intervention), the educational level of the female parent or guardian of the child, and the child's age. The statistical analysis did not find evidence that children living in households that either did not relocate or relocated for less than the full work period were significantly more likely to have a blood lead increase equal to or greater than 5 μg/dL than children living in households that fully relocated. Statistical analyses also did not reveal any single interior strategy to be more or less likely than others to be associated with a blood lead increase of 5 μg/dL or more

  3. Stable lead geochronology of fine-grained sediments in Southern Lake Michigan

    International Nuclear Information System (INIS)

    Robbins, J.A.; Edgington, D.N.

    1974-01-01

    In a previous article, it was shown that the vertical distribution of stable lead in the fine-grained sediments of Lake Michigan reflects the history of cultural lead inputs. It was found that the lead distributions in dated cores are quantitatively described by a universal time-dependent loading or source function which is a linear combination of estimated annual inputs of atmospheric lead derived from the combustion of leaded gasoline and the burning of coal in and around Chicago since about 1800. The existence of such a source function for lead implies that stable lead itself may be used to date sediment cores. Mercury depth profiles in western Lake Erie sediments have shown several horizons which correspond to the development of local industrial use of mercury over the past forty years or so. The construction of the lead source function for Lake Michigan sediments was based on only four lead-210 dated cores. To establish the validity of the source function concept, it is applied to the distribution of lead determined in many cores previously obtained from southern Lake Michigan

  4. Lead in school children from Morelos, Mexico: levels, sources and feasible interventions.

    Science.gov (United States)

    Farías, Paulina; Álamo-Hernández, Urinda; Mancilla-Sánchez, Leonardo; Texcalac-Sangrador, José Luis; Carrizales-Yáñez, Leticia; Riojas-Rodríguez, Horacio

    2014-12-01

    Lead is a pervasive pollutant, associated at low levels to many adverse health effects. To investigate lead levels, exposure pathways and intervention possibilities in school children from Alpuyeca, in Morelos, Mexico. Blood lead concentrations (BPb) were measured in 226 children in 2011. Exposure pathways were assessed through a questionnaire, lead measurements in different environmental matrices and spatial aggregation analysis of lead concentrations. BPb ranged from 1.5 to 36.5 ìg/dL, with a mean (SD) of 7.23 (4.9) ìg/dL. Sixty-four and 18% of the children had BPb > 5 ìg/dL and > 10 ìg/dL, respectively. The use of lead glazed ceramics was reported in almost half of the households; it was the main BPb determinant and it was associated with an increased risk of having BPb > 5 g/dL by 2.7 times (p = 0.001). Environmental samples were within US EPA’s lead recommended limits, and blood lead levels were randomly distributed in the community. Lead remains a public health problem in Alpuyeca, Mexico. Unlike other local pollutant lead exposure prevention can be achieved inexpensively and in a short term. Interventions should make mothers aware of lead's health effects and empower them to safeguard their children's health by avoiding the culturally ingrained use of lead glazed pottery.

  5. Application of the radioreagent method to the determination of trace quantities of lead

    International Nuclear Information System (INIS)

    Figueiredo, A.M.G.; Saiki, M.; Lima, F.W. de

    1983-01-01

    The radioreagent method of analysis was applied to determine trace quantities of lead in several types of samples. This method is based on the extraction of radioactive cobalt, displaced by lead from the cobalt chelate of ethylenediaminetetraacetate labeled with 60 Co, into a tetracycline-benzyl alcohol solution. The radioactivity of the released cobalt, extracted into the organic phase, measured by menas of a single channel gamma-ray analyzer coupled to a Na(T1) scintillation detector, is proportional to the lead concentration. The elements which might interfere with the analysis were removed by a chemical separation procedure of lead using dithizone. The method was applied for lead determination in air samples, gasoline and samples from the International Atomic Energy Agency, namely: simulated air filter (Air-3), fresh water (W-3), dried animal whole blood(A-2) and calcinated animal bone (A3/1). The sensitivity, accuracy and precision of the method were also discussed. (Author) [pt

  6. Multivariate statistical assessment of heavy metal pollution sources of groundwater around a lead and zinc plant

    Directory of Open Access Journals (Sweden)

    Zamani Abbas Ali

    2012-12-01

    Full Text Available Abstract The contamination of groundwater by heavy metal ions around a lead and zinc plant has been studied. As a case study groundwater contamination in Bonab Industrial Estate (Zanjan-Iran for iron, cobalt, nickel, copper, zinc, cadmium and lead content was investigated using differential pulse polarography (DPP. Although, cobalt, copper and zinc were found correspondingly in 47.8%, 100.0%, and 100.0% of the samples, they did not contain these metals above their maximum contaminant levels (MCLs. Cadmium was detected in 65.2% of the samples and 17.4% of them were polluted by this metal. All samples contained detectable levels of lead and iron with 8.7% and 13.0% of the samples higher than their MCLs. Nickel was also found in 78.3% of the samples, out of which 8.7% were polluted. In general, the results revealed the contamination of groundwater sources in the studied zone. The higher health risks are related to lead, nickel, and cadmium ions. Multivariate statistical techniques were applied for interpreting the experimental data and giving a description for the sources. The data analysis showed correlations and similarities between investigated heavy metals and helps to classify these ion groups. Cluster analysis identified five clusters among the studied heavy metals. Cluster 1 consisted of Pb, Cu, and cluster 3 included Cd, Fe; also each of the elements Zn, Co and Ni was located in groups with single member. The same results were obtained by factor analysis. Statistical investigations revealed that anthropogenic factors and notably lead and zinc plant and pedo-geochemical pollution sources are influencing water quality in the studied area.

  7. Multivariate statistical assessment of heavy metal pollution sources of groundwater around a lead and zinc plant.

    Science.gov (United States)

    Zamani, Abbas Ali; Yaftian, Mohammad Reza; Parizanganeh, Abdolhossein

    2012-12-17

    The contamination of groundwater by heavy metal ions around a lead and zinc plant has been studied. As a case study groundwater contamination in Bonab Industrial Estate (Zanjan-Iran) for iron, cobalt, nickel, copper, zinc, cadmium and lead content was investigated using differential pulse polarography (DPP). Although, cobalt, copper and zinc were found correspondingly in 47.8%, 100.0%, and 100.0% of the samples, they did not contain these metals above their maximum contaminant levels (MCLs). Cadmium was detected in 65.2% of the samples and 17.4% of them were polluted by this metal. All samples contained detectable levels of lead and iron with 8.7% and 13.0% of the samples higher than their MCLs. Nickel was also found in 78.3% of the samples, out of which 8.7% were polluted. In general, the results revealed the contamination of groundwater sources in the studied zone. The higher health risks are related to lead, nickel, and cadmium ions. Multivariate statistical techniques were applied for interpreting the experimental data and giving a description for the sources. The data analysis showed correlations and similarities between investigated heavy metals and helps to classify these ion groups. Cluster analysis identified five clusters among the studied heavy metals. Cluster 1 consisted of Pb, Cu, and cluster 3 included Cd, Fe; also each of the elements Zn, Co and Ni was located in groups with single member. The same results were obtained by factor analysis. Statistical investigations revealed that anthropogenic factors and notably lead and zinc plant and pedo-geochemical pollution sources are influencing water quality in the studied area.

  8. Constraining recent lead pollution sources in the North Pacific using ice core stable lead isotopes

    Science.gov (United States)

    Gross, B. H.; Kreutz, K. J.; Osterberg, E. C.; McConnell, J. R.; Handley, M.; Wake, C. P.; Yalcin, K.

    2012-08-01

    Trends and sources of lead (Pb) aerosol pollution in the North Pacific rim of North America from 1850 to 2001 are investigated using a high-resolution (subannual to annual) ice core record recovered from Eclipse Icefield (3017 masl; St. Elias Mountains, Canada). Beginning in the early 1940s, increasing Pb concentration at Eclipse Icefield occurs coevally with anthropogenic Pb deposition in central Greenland, suggesting that North American Pb pollution may have been in part or wholly responsible in both regions. Isotopic ratios (208Pb/207Pb and 206Pb/207Pb) from 1970 to 2001 confirm that a portion of the Pb deposited at Eclipse Icefield is anthropogenic, and that it represents a variable mixture of East Asian (Chinese and Japanese) emissions transported eastward across the Pacific Ocean and a North American component resulting from transient meridional atmospheric flow. Based on comparison with source material Pb isotope ratios, Chinese and North American coal combustion have likely been the primary sources of Eclipse Icefield Pb over the 1970-2001 time period. The Eclipse Icefield Pb isotope composition also implies that the North Pacific mid-troposphere is not directly impacted by transpolar atmospheric flow from Europe. Annually averaged Pb concentrations in the Eclipse Icefield ice core record show no long-term trend during 1970-2001; however, increasing208Pb/207Pb and decreasing 206Pb/207Pb ratios reflect the progressive East Asian industrialization and increase in Asian pollutant outflow. The post-1970 decrease in North American Pb emissions is likely necessary to explain the Eclipse Icefield Pb concentration time series. When compared with low (lichen) and high (Mt. Logan ice core) elevation Pb data, the Eclipse ice core record suggests a gradual increase in pollutant deposition and stronger trans-Pacific Asian contribution with rising elevation in the mountains of the North Pacific rim.

  9. Determination of particulate lead during MILAGRO / MCMA-2006 using Aerosol Mass Spectrometry

    Science.gov (United States)

    Salcedo, Dara; Onasch, T. B.; Aiken, A. C.; Williams, L. R.; de Foy, B.; Cubison, M. J.; Worsnop, D. R.; Molina, L. T.; Jimenez, J. L.

    2010-05-01

    City. Pb shows a diurnal cycle with a maximum in the early morning, which is typical of primary urban pollutants. Pb shows correlation with Zn, consistent with previous studies, while the sources of Pb appear to be at least partially disjoint from those of particulate chloride. Back trajectory analysis of the T0 Pb data suggests the presence of sources inside the urban area SSW and N of T0, with different chemical forms of Pb being associated with different source locations. High signals due to particulate lead were also detected in the PEMEX site; again, no correlation between Pb and chloride plumes was observed, suggesting mostly different sources for both species.

  10. Determination of particulate lead using aerosol mass spectrometry: MILAGRO/MCMA-2006 observations

    Science.gov (United States)

    Salcedo, D.; Onasch, T. B.; Aiken, A. C.; Williams, L. R.; de Foy, B.; Cubison, M. J.; Worsnop, D. R.; Molina, L. T.; Jimenez, J. L.

    2010-06-01

    with a maximum in the early morning, which is typical of primary urban pollutants. Pb shows correlation with Zn, consistent with previous studies, while the sources of Pb appear to be at least partially disjoint from those of particulate chloride. Back trajectory analysis of the T0 Pb data suggests the presence of sources inside the urban area SSW and N of T0, with different chemical forms of Pb being associated with different source locations. High signals due to particulate lead were also detected in the PEMEX site; again, no correlation between Pb and chloride plumes was observed, suggesting mostly different sources for both species.

  11. Neutron source strength determination for on-line reactivity measurements

    Energy Technology Data Exchange (ETDEWEB)

    Hoogenboom, J.E.; Sluijs, A.R. van der

    1988-01-01

    A method is described to determine the effective neutron source strength in a nuclear reactor, which must be known when calculating the time-varying reactivity from inverse reactor kinetics for a reactor at low power. When for an initially subcritical reactor the reactivity is changed and kept constant after the change, the effective source strength can be determined from a linear regression of reactor power to a function proportional to the emission rate of delayed neutrons, which can be calculated from the reactor power history. In view of the relatively strong noise present in the reactor power signal at low power, a grouping method for the regression is preferred over the least-squares method. Experiments with a reactor simulator with known source strength showed good agreement. Application to actual reactor signals gave consistent and satisfactory results.

  12. Determining the sources of fine-grained sediment using the Sediment Source Assessment Tool (Sed_SAT)

    Science.gov (United States)

    Gorman Sanisaca, Lillian E.; Gellis, Allen C.; Lorenz, David L.

    2017-07-27

    A sound understanding of sources contributing to instream sediment flux in a watershed is important when developing total maximum daily load (TMDL) management strategies designed to reduce suspended sediment in streams. Sediment fingerprinting and sediment budget approaches are two techniques that, when used jointly, can qualify and quantify the major sources of sediment in a given watershed. The sediment fingerprinting approach uses trace element concentrations from samples in known potential source areas to determine a clear signature of each potential source. A mixing model is then used to determine the relative source contribution to the target suspended sediment samples.The computational steps required to apportion sediment for each target sample are quite involved and time intensive, a problem the Sediment Source Assessment Tool (Sed_SAT) addresses. Sed_SAT is a user-friendly statistical model that guides the user through the necessary steps in order to quantify the relative contributions of sediment sources in a given watershed. The model is written using the statistical software R (R Core Team, 2016b) and utilizes Microsoft Access® as a user interface but requires no prior knowledge of R or Microsoft Access® to successfully run the model successfully. Sed_SAT identifies outliers, corrects for differences in size and organic content in the source samples relative to the target samples, evaluates the conservative behavior of tracers used in fingerprinting by applying a “Bracket Test,” identifies tracers with the highest discriminatory power, and provides robust error analysis through a Monte Carlo simulation following the mixing model. Quantifying sediment source contributions using the sediment fingerprinting approach provides local, State, and Federal land management agencies with important information needed to implement effective strategies to reduce sediment. Sed_SAT is designed to assist these agencies in applying the sediment fingerprinting

  13. Source and impact of lead contamination on {delta}-aminolevulinic acid dehydratase activity in several marine bivalve species along the Gulf of Cadiz

    Energy Technology Data Exchange (ETDEWEB)

    Company, R.; Serafim, A.; Lopes, B.; Cravo, A. [CIMA, University of Algarve, Campus de Gambelas, 8005-139 Faro (Portugal); Kalman, J.; Riba, I.; DelValls, T.A. [Catedra UNESCO/UNITWIN/WiCop, Department of Physical-Chemistry, Faculty Marine and Environmental Sciences, University of Cadiz, 11510 Puerto Real, Cadiz (Spain); Blasco, J. [Instituto Ciencias Marinas Andalucia (CSIC), Campus Rio San Pedro, 11510 Puerto Real, Cadiz (Spain); Delgado, J. [Department of Geology, University of Huelva, Avda Fuerzas Armadas s/n, 21071 Huelva (Spain); Sarmiento, A.M. [Catedra UNESCO/UNITWIN/WiCop, Department of Physical-Chemistry, Faculty Marine and Environmental Sciences, University of Cadiz, 11510 Puerto Real, Cadiz (Spain); Department of Geology, University of Huelva, Avda Fuerzas Armadas s/n, 21071 Huelva (Spain); Nieto, J.M. [Department of Geology, University of Huelva, Avda Fuerzas Armadas s/n, 21071 Huelva (Spain); Shepherd, T.J.; Nowell, G. [Department of Earth Sciences, University of Durham, Science Laboratories, Durham DH1 3LE (United Kingdom); Bebianno, M.J., E-mail: mbebian@ualg.pt [CIMA, University of Algarve, Campus de Gambelas, 8005-139 Faro (Portugal)

    2011-01-17

    Coastal areas and estuaries are particularly sensitive to metal contamination from anthropogenic sources and in the last few decades the study of space-time distribution and variation of metals has been extensively researched. The Gulf of Cadiz is no exception, with several rivers draining one of the largest concentrations of sulphide deposits in the world, the Iberian Pyrite Belt (IPB). Of these rivers, the Guadiana, one of the most important in the Iberian Peninsula, together with smaller rivers like the Tinto and Odiel, delivers a very high metal load to the adjacent coastal areas. The purpose of this work was to study the source and impact of lead (Pb) drained from historical or active mining areas in the IPB on the activity of a Pb inhibited enzyme ({delta}-aminolevulinic acid dehydratase, ALAD) in several bivalve species along the Gulf of Cadiz. Seven marine species (Chamelea gallina, Mactra corallina, Donax trunculus, Cerastoderma edule, Mytilus galloprovincialis, Scrobicularia plana and Crassostrea angulata) were collected at 12 sites from Mazagon, near the mouth of the rivers Tinto and Odiel (Spain), to Cacela Velha (Ria Formosa lagoon system, Portugal). Lead concentrations, ALAD activity and lead isotope ratios ({sup 206}Pb/{sup 204}Pb, {sup 207}Pb/{sup 204}Pb and {sup 208}Pb/{sup 204}Pb) were determined in the whole soft tissues. The highest Pb concentrations were determined in S. plana (3.50 {+-} 1.09 {mu}g g{sup -1} Pb d.w.) and D. trunculus (1.95 {+-} 0.10 {mu}g g{sup -1} Pb d.w.), while M. galloprovincialis and C. angulata showed the lowest Pb levels (<0.38 {mu}g g{sup -1} Pb d.w.). In general, ALAD activity is negatively correlated with total Pb concentration. However this relationship is species dependent (e.g. linear for C. gallina ALAD = -0.36[Pb] + 0.79; r = 0.837; or exponential for M. galloprovincialis ALAD = 2.48e{sup -8.3[Pb]}; r = 0.911). This indicates that ALAD activity has considerable potential as a biomarker of Pb and moreover, in

  14. Source and impact of lead contamination on δ-aminolevulinic acid dehydratase activity in several marine bivalve species along the Gulf of Cadiz

    International Nuclear Information System (INIS)

    Company, R.; Serafim, A.; Lopes, B.; Cravo, A.; Kalman, J.; Riba, I.; DelValls, T.A.; Blasco, J.; Delgado, J.; Sarmiento, A.M.; Nieto, J.M.; Shepherd, T.J.; Nowell, G.; Bebianno, M.J.

    2011-01-01

    Coastal areas and estuaries are particularly sensitive to metal contamination from anthropogenic sources and in the last few decades the study of space-time distribution and variation of metals has been extensively researched. The Gulf of Cadiz is no exception, with several rivers draining one of the largest concentrations of sulphide deposits in the world, the Iberian Pyrite Belt (IPB). Of these rivers, the Guadiana, one of the most important in the Iberian Peninsula, together with smaller rivers like the Tinto and Odiel, delivers a very high metal load to the adjacent coastal areas. The purpose of this work was to study the source and impact of lead (Pb) drained from historical or active mining areas in the IPB on the activity of a Pb inhibited enzyme (δ-aminolevulinic acid dehydratase, ALAD) in several bivalve species along the Gulf of Cadiz. Seven marine species (Chamelea gallina, Mactra corallina, Donax trunculus, Cerastoderma edule, Mytilus galloprovincialis, Scrobicularia plana and Crassostrea angulata) were collected at 12 sites from Mazagon, near the mouth of the rivers Tinto and Odiel (Spain), to Cacela Velha (Ria Formosa lagoon system, Portugal). Lead concentrations, ALAD activity and lead isotope ratios ( 206 Pb/ 204 Pb, 207 Pb/ 204 Pb and 208 Pb/ 204 Pb) were determined in the whole soft tissues. The highest Pb concentrations were determined in S. plana (3.50 ± 1.09 μg g -1 Pb d.w.) and D. trunculus (1.95 ± 0.10 μg g -1 Pb d.w.), while M. galloprovincialis and C. angulata showed the lowest Pb levels ( -1 Pb d.w.). In general, ALAD activity is negatively correlated with total Pb concentration. However this relationship is species dependent (e.g. linear for C. gallina ALAD = -0.36[Pb] + 0.79; r = 0.837; or exponential for M. galloprovincialis ALAD = 2.48e -8.3[Pb] ; r = 0.911). This indicates that ALAD activity has considerable potential as a biomarker of Pb and moreover, in marine bivalve species with different feeding habits. Lead isotope data

  15. Determined Initial lead for South Of Isua (SOI) terrain suggests a single homogeneous source for it and possibly other archaean rocks

    Science.gov (United States)

    Tera, F.

    2011-12-01

    A Thorogenic-Uranogenic Lead Isotope Plane (TULIP), which entails plotting 206/208 (or its reverse) vs 207/208 (or its reverse), was applied to the Pb data on South of Isua (SOI) by Kamber et al., (1). When the data on 20 samples of these rocks and feldspars are plotted in pairs (each pair is a rock and its feldspar) on TULIP, they fall on 10 mixing lines that converge on a single spot (Fig. 1). This is the end member initial lead (EMIL). The 206/208 & 207/208 so determined are 0.3675 and 0.43525, respectively. From these values one calculates 207/206 = 1.1843 ± 0.0007, for EMIL. This pattern requires either: A) each pair has a singular kappa, K = 232Th/238U, different from others, or B) a pair's in situ decay Pb was homogenized in recent times. On 204/206 vs 207/206 diagram, the whole rocks of SOI define a 3.776 Ga isochron (2). From this and EMIL's 207/206, one obtains: 206/204 = 10.977, 207/204 = 12.974; and 208/204 = 29.756. This singularity of initial Pb contrasts with a deduced variability by the original authors (1). EMIL's radiogenic *(207/206) = 1.6220, gives a single-stage age = 5.9 Ga, indicating inapplicability of its evolution in one stage. Also, the μ calculated from 238U-206Pb for the single stage is different from that inferred from 235U-207Pb, confirming disqualification of this scenario. Reconciliation of the two decay schemes necessitates assumption of EMIL evolution in a minimum of two stages. Starting at 4.563 Ga, five scenarios were assumed: First stage ends and second starts at 4.55, 4.54, 4.53, 4.52 or 4.51 Ga. Second stages end at 3.776 Ga. The calculated μ1 for the first stage are 106, 59.5, 44.6, 36.3 and 30.9 respectively. For μ2 the change is limited, from 5.45 to 5.28. Only an average calculated K for both stages is possible. For the five outlined scenarios it ranges from 1.118 to 1.111. Earlier, Tera (3) observed that initial Pb of the oldest terrestrial reservoir requires evolution in two stages. There too μ1 >> μ2. Data on

  16. Effect of the lead screen in the radiographic image using iridium 192 as a source

    International Nuclear Information System (INIS)

    Garate Rojas, M.

    1983-01-01

    It's presented the effect of the lead screen in the image obtained on an impressionable film used in industrial gammagraphy. The source used was Iridium 192 and the tests were simulated like a real inspection. (E.G.) [pt

  17. Enzymatic determination of cadmium, zinc, and lead in plant materials

    International Nuclear Information System (INIS)

    Muginova, S.V.; Veselova, I.A.; Parova, L.M.; Shekhovtseva, T.N.

    2008-01-01

    Prospects are outlined for using the following enzymes (native and immobilized on polyurethane foam) in the rapid and highly sensitive determination of cadmium, zinc, and lead ions in plant materials (wild grass, fresh pea, and grape): horseradish peroxidase and alkaline phosphatases isolated from chicken intestine and Greenland seal small intestine. The analytical ranges of the above metals are 1x10 -3 -25; 7x10 -3 -250, and 3x10 -2 -67 mg/kg dry matter, respectively. The enzymatic determination procedures developed are based on the inhibiting effect of metal ions on the catalytic activity of peroxidase in the oxidation of o-dianisidine with hydrogen peroxide and alkaline phosphatases in the hydrolysis of p-nitrophenyl phosphate. The rates of enzymatic reactions were monitored spectrophotometrically or visually. In the analysis of plant extracts, their high acidity was diminished by choosing optimum dilution factors and pH values for test samples and the nature and concentration of a buffer solution. The interference of iron(III) was removed by introducing a 0.1 M tartaric acid solution into the indicator reaction. The accuracy of the results of the enzymatic determination of cadmium, zinc, and lead in plant materials was supported by atomic absorption spectrometry and anodic stripping voltammetry [ru

  18. Method to determine the strength of a neutron source

    Energy Technology Data Exchange (ETDEWEB)

    Vega C, H.R.; Manzanares A, E.; Hernandez D, V.M.; Chacon R, A.; Mercado, G.A. [UAZ, A.P. 336, 98000 Zacatecas (Mexico); Gallego, E.; Lorente, A. [Depto. Ingenieria Nuclear, Universidad Politecnica de Madrid, (Spain)

    2006-07-01

    The use of a gamma-ray spectrometer with a 3 {phi} x 3 NaI(Tl) detector, with a moderator sphere has been studied in the aim to measure the neutron fluence rate and to determine the source strength. Moderators with a large amount of hydrogen are able to slowdown and thermalize neutrons; once thermalized there is a probability that thermal neutron to be captured by hydrogen producing 2.22 MeV prompt gamma-ray. The pulse-height spectrum collected in a multicharmel analyzer shows a photopeak around 2.22 MeV whose net area is proportional to total neutron fluence rate and to the neutron source strength. The characteristics of this system were determined by a Monte Carlo study using the MCNP 4C code, where a detailed model of the Nal(Tl) was utilized. As moderators 3, 5, and 10 inches-diameter spheres where utilized and the response was calculated for monoenergetic and isotopic neutrons sources. (Author)

  19. Determination of lead at nanogram level in water samples by ...

    African Journals Online (AJOL)

    A novel method of chemistry applicable to the determination of trace lead in water samples based on the resonance light scattering (RLS) technique has been developed. In dilute phosphoric acid medium, in the presence of a large excess of I-, Pb(II) can form [PbI4]2-, which further reacts with tetrabutyl ammonium bromide ...

  20. Determinants of maternal and umbilical blood lead levels: a cross-sectional study, Mosul, Iraq

    Directory of Open Access Journals (Sweden)

    Al-Jomard Raghad A

    2009-03-01

    Full Text Available Abstract Background The populations who are most sensitive to lead exposure from various sources are pregnant women and their newborns. Aiming to explore the presence of correlation between maternal and cord blood lead levels and to identify potential predictors that may influence both levels, the present study has been conducted. Methods A cross-sectional study was conducted covering 350 full terms maternal-newborns pairs from Mosul maternity hospitals. Data were obtained directly from women just before delivery by the use of a detailed questionnaire form. Maternal and umbilical blood lead levels were estimated using LEADCARE® Blood Lead Testing System and Kits. Results A positive significant correlation was found between maternal and cord blood lead values (r = 0.856, p = 0.001. By backward stepwise logistic regression analysis the followings emerged as significant potential predictors of high maternal blood lead: low parity, smoking and Hb level Conclusion Study results have provided baseline data needed to be transformed to decision makers to implement measures to eliminate lead from the environment and protect future generation from its deleterious effects.

  1. A on-line method for the determination of lead and lead isotope ratios in fresh and saline waters by inductively coupled plasma mass spectrometry

    International Nuclear Information System (INIS)

    Halicz, Ludwik; Lam, J.W.H.; McLaren, J.W.

    1994-01-01

    A previously reported on-line ICP-MS method for the determination of lead and other trace elements in seawater has been re-examined to determine its suitability for the determination of lead isotope ratios ( 206 Pb/ 207 Pb and 207 Pb/ 208 Pb) in fresh and saline natural waters. A detection limit of 0.9 ng/1 for total lead (for a 5 ml sample) was achieved. Precision of isotope ratio data was 0.2-0.3% RSD at a Pb concentration of 1 μg/l, and was still better than 2% at concentrations of only 10-40 ng/1 in seawater certified reference materials (CRMs). For all three natural water CRMs examined, measured precision was very close to the limit predicted by counting statistics. (Author)

  2. Determination of lead 210 in scales from industrial processes

    International Nuclear Information System (INIS)

    Faria, Lígia S.; Moreira, Rubens M.; Kastner, Geraldo F.; Barbosa, João B.S.

    2017-01-01

    Industrial processes such as oil and gas extraction and groundwater exploitation are examples of installations that can accumulate naturally occurring radioactive materials (NORM) during the extraction and production. Lead-210 deposits in the production can be formed by the same mechanisms that occur in the environment through the support of Radon-222, (where 210 Pb is produced at 222 Rn decay) or without support, as 210 Pb. The objective of this work is to evaluate the mineralogical characteristics and determine the activity of lead-210 in the scales using the X-Ray Diffraction and Gamma Spectrometry techniques. Were analyzed fifteen samples, four scales from oil industry, ten scales from groundwater conductors and one for groundwater supply pipe. The highest activity found in the oil scale and groundwater conductors scale was 0.30 ± 0.06 Bq g -1 and 3.80 ± 0.20 Bq g -1 , respectively. (author)

  3. SU-F-T-54: Determination of the AAPM TG-43 Brachytherapy Dosimetry Parameters for A New Titanium-Encapsulated Yb-169 Source by Monte Carlo Calculations

    Energy Technology Data Exchange (ETDEWEB)

    Reynoso, F [UT MD Anderson Cancer Center, Houston, TX (United States); Washington University School of Medicine, St. Louis, MO (United States); Munro, J [Source Production & Equipment Co., Inc., St. Rose, LA (United States); Cho, S [UT MD Anderson Cancer Center, Houston, TX (United States)

    2016-06-15

    Purpose: To determine the AAPM TG-43 brachytherapy dosimetry parameters of a new titanium-encapsulated Yb-169 source designed to maximize the dose enhancement during gold nanoparticle-aided radiation therapy (GNRT). Methods: An existing Monte Carlo (MC) model of the titanium-encapsulated Yb-169 source, which was described in the current investigators’ published MC optimization study, was modified based on the source manufacturer’s detailed specifications, resulting in an accurate model of the titanium-encapsulated Yb-169 source that was actually manufactured. MC calculations were then performed using the MCNP5 code system and the modified source model, in order to obtain a complete set of the AAPM TG-43 parameters for the new Yb-169 source. Results: The MC-calculated dose rate constant for the new titanium-encapsulated Yb-169 source was 1.05 ± 0.03 cGy per hr U, indicating about 10% decrease from the values reported for the conventional stainless steel-encapsulated Yb-169 sources. The source anisotropy and radial dose function for the new source were found similar to those reported for the conventional Yb-169 sources. Conclusion: In this study, the AAPM TG-43 brachytherapy dosimetry parameters of a new titanium-encapsulated Yb-169 source were determined by MC calculations. The current results suggested that the use of titanium, instead of stainless steel, to encapsulate the Yb-169 core would not lead to any major change in the dosimetric characteristics of the Yb-169 source, while it would allow more low energy photons being transmitted through the source filter thereby leading to an increased dose enhancement during GNRT. Supported by DOD/PCRP grant W81XWH-12-1-0198 This investigation was supported by DOD/PCRP grant W81XWH-12-1- 0198.

  4. Application of source-receptor models to determine source areas of biological components (pollen and butterflies)

    OpenAIRE

    M. Alarcón; M. Àvila; J. Belmonte; C. Stefanescu; R. Izquierdo

    2010-01-01

    The source-receptor models allow the establishment of relationships between a receptor point (sampling point) and the probable source areas (regions of emission) through the association of concentration values at the receptor point with the corresponding atmospheric back-trajectories, and, together with other techniques, to interpret transport phenomena on a synoptic scale. These models are generally used in air pollution studies to determine the areas of origin of chemical compounds measured...

  5. Bayesian source term determination with unknown covariance of measurements

    Science.gov (United States)

    Belal, Alkomiet; Tichý, Ondřej; Šmídl, Václav

    2017-04-01

    Determination of a source term of release of a hazardous material into the atmosphere is a very important task for emergency response. We are concerned with the problem of estimation of the source term in the conventional linear inverse problem, y = Mx, where the relationship between the vector of observations y is described using the source-receptor-sensitivity (SRS) matrix M and the unknown source term x. Since the system is typically ill-conditioned, the problem is recast as an optimization problem minR,B(y - Mx)TR-1(y - Mx) + xTB-1x. The first term minimizes the error of the measurements with covariance matrix R, and the second term is a regularization of the source term. There are different types of regularization arising for different choices of matrices R and B, for example, Tikhonov regularization assumes covariance matrix B as the identity matrix multiplied by scalar parameter. In this contribution, we adopt a Bayesian approach to make inference on the unknown source term x as well as unknown R and B. We assume prior on x to be a Gaussian with zero mean and unknown diagonal covariance matrix B. The covariance matrix of the likelihood R is also unknown. We consider two potential choices of the structure of the matrix R. First is the diagonal matrix and the second is a locally correlated structure using information on topology of the measuring network. Since the inference of the model is intractable, iterative variational Bayes algorithm is used for simultaneous estimation of all model parameters. The practical usefulness of our contribution is demonstrated on an application of the resulting algorithm to real data from the European Tracer Experiment (ETEX). This research is supported by EEA/Norwegian Financial Mechanism under project MSMT-28477/2014 Source-Term Determination of Radionuclide Releases by Inverse Atmospheric Dispersion Modelling (STRADI).

  6. Determination of mercury, lead and cadmium in water by the CRA-atomic absorption spectrophotometry with solvent extraction

    International Nuclear Information System (INIS)

    Shim, Y.B.; Won, M.S.; Kim, C.J.

    1980-01-01

    The method of CRA-atomic absorption spectrophotometer with solvent extraction for the determination of mercury, lead and cadmium in water was studied. The optimum extracting conditions for CRA-atomic absorption spectrophotometry were the following: the complexes of mercury, lead and cadmium with dithizone were separated from the aqueous solution and concentrated into the 10 ml chloroform solution. Back extraction was performed; the concentrated mercury, lead and cadmium was extracted from the chloroform solution into the 10 ml 6-normal aqueous hydrochloric acid solution. In this case, recovery ratios were the following: mercury was 94.7%, lead 97.7% and cadmium 103.6%. The optimum operating conditions for the determination of mercury, lead and cadmium by the CRA-atomic absorption spectrophotometry also were investigated to test the dry step, ash step and atomization step for each metal. The experimental results of standard addition method were the following: the determination limit of each metal within 6% relative deviation was that lead was 0.04 ppb, and cadmium 0.01 ppb. Especially, mercury has been known impossible to determine by CRA-atomic absorption spectrophotometry until now. But in this study, mercury can be determined with CRA-atomic absorption spectrophotometer. Its determination limit was 4 ppb within 8% relative deviation. (author)

  7. Gamma radiation shielding analysis of lead-flyash concretes

    International Nuclear Information System (INIS)

    Singh, Kanwaldeep; Singh, Sukhpal; Dhaliwal, A.S.; Singh, Gurmel

    2015-01-01

    Six samples of lead-flyash concrete were prepared with lead as an admixture and by varying flyash content – 0%, 20%, 30%, 40%, 50% and 60% (by weight) by replacing cement and keeping constant w/c ratio. Different gamma radiation interaction parameters used for radiation shielding design were computed theoretically and measured experimentally at 662 keV, 1173 keV and 1332 keV gamma radiation energy using narrow transmission geometry. The obtained results were compared with ordinary-flyash concretes. The radiation exposure rate of gamma radiation sources used was determined with and without lead-flyash concretes. - Highlights: • Concrete samples with lead as admixture were casted with flyash replacing 0%, 20%, 30%, 40%, 50% and 60% of cement content (by weight). • Gamma radiation shielding parameters of concretes for different gamma ray sources were measured. • The attenuation results of lead-flyash concretes were compared with the results of ordinary flyash concretes

  8. Lead Equivalent Thickness Measurement for Mixed Compositions of Barium Plaster Block

    International Nuclear Information System (INIS)

    Norriza Mohd Isa; Muhammad Jamal Muhammad Isa; Nur Shahriza Zainuddin; Mohd Khairusalih Md Zin; Shahrul Azlan Azizan

    2016-01-01

    Measurement of lead equivalent thickness for ionizing radiation exposure room wall shall be performed as stated in Malaysian Standard MS 838. A few numbers of sample blocks with different mixture of barium plaster compositions based and varies certain thickness as a shielding material for exposure room wall belong to a local company were tested by using Cs-137, Co-60 and Am-241 with different activities . Radiations passed through the samples were detected with calibrated survey meter. The distance between radiation source and the detector is about 40 cm. Lead uniformity test on the samples was also determined at three labeled points on the samples. Lead equivalent thicknesses for the samples were evaluated based on a calibration graph that was plotted with lead sheets and with the radiation sources. Results shown that lead equivalent thickness for the samples with same actual physical thickness represent different values for different sources. (author)

  9. Determination of lead 210 in scales from industrial processes

    Energy Technology Data Exchange (ETDEWEB)

    Faria, Lígia S.; Moreira, Rubens M.; Kastner, Geraldo F.; Barbosa, João B.S., E-mail: ligsfaria@gmail.com, E-mail: rubens@cdtn.br, E-mail: gfk@cdtn.br, E-mail: jbsb@cdtn.br [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2017-11-01

    Industrial processes such as oil and gas extraction and groundwater exploitation are examples of installations that can accumulate naturally occurring radioactive materials (NORM) during the extraction and production. Lead-210 deposits in the production can be formed by the same mechanisms that occur in the environment through the support of Radon-222, (where {sup 210}Pb is produced at {sup 222}Rn decay) or without support, as {sup 210}Pb. The objective of this work is to evaluate the mineralogical characteristics and determine the activity of lead-210 in the scales using the X-Ray Diffraction and Gamma Spectrometry techniques. Were analyzed fifteen samples, four scales from oil industry, ten scales from groundwater conductors and one for groundwater supply pipe. The highest activity found in the oil scale and groundwater conductors scale was 0.30 ± 0.06 Bq g{sup -1} and 3.80 ± 0.20 Bq g{sup -1}, respectively. (author)

  10. Determination of particulate lead using aerosol mass spectrometry: MILAGRO/MCMA-2006 observations

    Directory of Open Access Journals (Sweden)

    D. Salcedo

    2010-06-01

    from fast evaporation, which is likely due to the higher vapor pressure of the compounds generating PbCl+. This is consistent with the evaporation model results. Levels of particulate Pb measured at T0 were similar to previous studies in Mexico City. Pb shows a diurnal cycle with a maximum in the early morning, which is typical of primary urban pollutants. Pb shows correlation with Zn, consistent with previous studies, while the sources of Pb appear to be at least partially disjoint from those of particulate chloride. Back trajectory analysis of the T0 Pb data suggests the presence of sources inside the urban area SSW and N of T0, with different chemical forms of Pb being associated with different source locations. High signals due to particulate lead were also detected in the PEMEX site; again, no correlation between Pb and chloride plumes was observed, suggesting mostly different sources for both species.

  11. Stable lead isotopic analyses of historic and contemporary lead contamination of San Francisco Bay estuary

    Science.gov (United States)

    Ritson, P.I.; Bouse, R.M.; Flegal, A.R.; Luoma, S.N.

    1999-01-01

    Variations in stable lead isotopic composition (240Pb, 206Pb, 207Pb, 208Pb) in three sediment cores from the San Francisco Bay estuary document temporal changes in sources of lead during the past two centuries. Sediment, with lead from natural geologic sources, and relatively homogeneous lead isotopic compositions are overlain by sediments whose isotopic compositions indicate change in the sources of lead associated with anthropogenic modification of the estuary. The first perturbations of lead isotopic composition in the cores occur in the late 1800s concordant with the beginning of industrialization around the estuary. Large isotopic shifts, toward lower 206Pb/207Pb, occur after the turn of the century in both Richardson and San Pablo Bays. A similar relationship among lead isotopic compositions and lead concentrations in both Bays suggest contamination from the same source (a lead smelter). The uppermost sediments (post 1980) of all cores also have a relatively homogenous lead isotopic composition distinct from pre-anthropogenic and recent aerosol signatures. Lead isotopic compositions of leachates from fourteen surface sediments and five marsh samples from the estuary were also analyzed. These analyses suggest that the lead isotopic signature identified in the upper horizons of the cores is spatially homogeneous among recently deposited sediments throughout the estuary. Current aerosol lead isotopic compositions [Smith, D.R., Niemeyer, S., Flegal, A.R., 1992. Lead sources to California sea otters: industrial inputs circumvent natural lead biodepletion mechanisms. Environmental Research 57, 163-175] are distinct from the isotopic compositions of the surface sediments, suggesting that the major source of lead is cycling of historically contaminated sediments back through the water column. Both the upper core sediments and surface sediments apparently derive their lead predominantly from sources internal to the estuary. These results support the idea that

  12. Precise Determination of the 1s Lamb Shift in Hydrogen-Like Lead and Gold Using Microcalorimeters

    Science.gov (United States)

    Kraft-Bermuth, S.; Andrianov, V.; Bleile, A.; Echler, A.; Egelhof, P.; Grabitz, P.; Ilieva, S.; Kiselev, O.; Kilbourne, C.; McCammon, D.; hide

    2017-01-01

    Quantum electrodynamics in very strong Coulomb fields is one scope which has not yet been tested experimentally with sufficient accuracy to really determine whether the perturbative approach is valid. One sensitive test is the determination of the 1s Lamb shift in highly-charged very heavy ions. The 1s Lamb shift of hydrogen-like lead (Pb81+) and gold (Au78+) has been determined using the novel detector concept of silicon microcalorimeters for the detection of hard x-rays. The results of (260 +/- 53) eV for lead and (211 +/- 42) eV for gold are within the error bars in good agreement with theoretical predictions. To our knowledge, for hydrogen-like lead, this represents the most accurate determination of the 1s Lamb shift.

  13. Lead in the blood of children living close to industrial point sources in Bulgaria and Poland

    Science.gov (United States)

    Willeke-Wetstein, C.; Bainova, A.; Georgieva, R.; Huzior-Balajewicz, A.; Bacon, J. R.

    2003-05-01

    ln Eastern European countries some industrial point sources are still suspected to have unacceptable emission rates of lead that pose a major health risk in particular to children. An interdisciplinary research project under the auspices of the EU had the aims (I) to monitor the current contamination of two industrial zones in Bulgaria and Poland, (2) to relate the Pb levels in ecological strata to the internal exposure of children, (3) to develop public health strategies in order to reduce the health risk by heavy metals. The human monitoring of Pb in Poland did not show increased health risks for the children living in an industrial zone close to Krakow. Bulgarian children, however, exceeded the WHO limit of 100 μg lead per litre blood by over one hundred percent (240 μg/1). Samples of soil, fodder and livestock organs showed elevated concentrations of lead. Recent literature results are compared with the findings in Bulgaria and Poland. The sources of the high internal exposure of children are discussed. Public health strategies to prevent mental dysfunction in Bulgarian children at risk include awareness building and social masures.

  14. Determination of disintegration rates of a 60Co point source and volume sources by the sum-peak method

    International Nuclear Information System (INIS)

    Kawano, Takao; Ebihara, Hiroshi

    1990-01-01

    The disintegration rates of 60 Co as a point source (<2 mm in diameter on a thin plastic disc) and volume sources (10-100 mL solutions in a polyethylene bottle) are determined by the sum-peak method. The sum-peak formula gives the exact disintegration rate for the point source at different positions from the detector. However, increasing the volume of the solution results in enlarged deviations from the true disintegration rate. Extended sources must be treated as an amalgam of many point sources. (author)

  15. Lead poisoning: The invisible disease

    Science.gov (United States)

    Friend, Milton

    1989-01-01

    Lead poisoning is an intoxication resulting from absorption of hazardous levels of lead into body tissues. Lead pellets from shot shells, when ingested, are the most common source of lead poisoning in migratory birds. Other far less common sources include lead fishing sinkers, mine wastes, paint pigments, bullets, and other lead objects that are swallowed.

  16. Lead intoxication: clinic and diagnostic evaluation in children

    Directory of Open Access Journals (Sweden)

    Martínez-Riera Nora

    2012-03-01

    Full Text Available Poverty, poor nutrition, environmental and social injustice prevailing in Latin America are factorsthat determine the action of pollutants on children. Lead poisoning and pollution constitute apublic health problem throughout the world. Lead affects multiple organs: nervous system particularly,hematopoietic, renal, endocrine, bone and others. Objective: to assess clinical, biochemicaland vascular effects in children exposed to known source of lead. Materials and methods: Sevenchildren with defined source lead exposure were studied, general and specific lead laboratorywere made. Endothelial function and electrocardiographic parameters were assessed. Statistic:descriptive. Results: Age average was 6,2 years (DE± 1, 6, average haematocrit 31% (DE±0,02;hemoglobin average 10,2 g/dl (DE± 0,78. 100% presented hypochromia, microcitosis, anemiaand marked anisocytosis. Lead average: 37,9 ug/dl (DE±6,22, ALA-D average: 8,9 U/L (DE±4,5.No changes were found in lipid profile and kidney function. All presented microalbuminuriaand endothelial dysfunction. Conclusion: These results show the effects of environmental leadexposure that can result in children not occupationally exposed.

  17. Experimental study using of a G-M counter and {sup 137}Cs source to measure the HVL with lead

    Energy Technology Data Exchange (ETDEWEB)

    Kwon, Dae Cheol [Dept. of Radiological Science, College of Health Science, Shinhan University, Uijeongbu (Korea, Republic of); Dong, Kyung Rae [Dept. of Radiological Technology, Gwangju Health University, Gwangju (Korea, Republic of)

    2016-11-15

    HVL(half-value layer) of lead was measured experimentally using a lead and {sup 137}Cs (370 kBq) source and a G-M counter in which is used a lot of material for shielding HVL measured. {sup 137}Cs in holder to 10 cm and start measuring the radiation. Continue addition of lead of the lead thickness of 1 mm one by one to continue the measurement. By measuring four times the natural radiation of 100 seconds and records the count value and the average rate to be displayed on the meter. Background radiation was a 4 times a count rate and the average 108 (100 s{sup -1}) as a result of measuring the average measurement, the standard deviation was determined to be 1.08 (s{sup -1}). An increase in the thickness of lead initial count rate starting from 920 (N) count rate is decreased with increase in the thickness of lead. Net counting rate, starting with the initial 8.12 (s{sup -1}) showed a decrease with increasing thickness, the standard deviation of the results was decreased from 0.303 (s{sup -1}) to 0.196 (s{sup -1}). Net counting rate is reduced to obtain the result that each half thickness of nappan about 7 mm. Was reduced similarly to the exponential function graph correlation coefficient (R{sup 2}) was found to be 0.9869. Half-value layer which is the initial net counting rate 7.514 (s{sup -1}) is a half the 7 mm to 3.757 (s{sup -1}). In conclusion, it was confirmed the theoretical HVL of lead 7.19 mm and experimentally measured results matched the measured HVL 7 mm.

  18. Application of radio-reagent method in the determination of lead trace amounts

    International Nuclear Information System (INIS)

    Figueiredo, A.M.G.

    1983-01-01

    A radiometric method for trace analysis of lead was established, based on the displacement reaction between lead and the complex cobalt - ethylenediaminetetracetate labelled with 60 Co (Co* - EDTA), which is named radioreagent. The radioactive cobalt displaced by lead is separated from the excess of radioreagent by the solvent extraction technique, using a solution of tetracycline (Tc) in benzyl alcohol. The activity of the extracted cobalt is then measured by means of a single-channel gamma-ray analyser coupled to a NaI (Tl) scintillation detector, the activity being proportional to the lead concentration, in a range from 2.5 to 150 μg. The interference of several elements (V, Th, Sc, Fe, La, Yb, Cu, Cd, Zn, Mn, Ni, Co, Al and Sn) was investigated by means of a previous separation between lead and these interfering elements. The analyses of artificial samples containing lead and the interfering elements gave a yield of 91.1 + - 3.2 %. The detection limit achieved by the method was 3.3 μg of lead. The radioreagent method was applied to lead analysis of samples from IAEA, namely: simulated air filter (Air-3), fresh water (W-3), dried animal blood (A-2) and calcinated animal bone (A-3/1). Lead was also determined in gasoline samples and air samples, these latter collected in the surroundings of the IPEN/CNEN/SP (Brazil). (Author) [pt

  19. Prenatal lead exposure and relationship with maternal exposure determinants in a public maternity hospital of La Plata, Argentina.

    Science.gov (United States)

    Martins, Enrique; Varea, Ana; Apezteguía, María; González, Horacio F; Girardelli, Ana; Caro, Laura Sanchez; Lobisuto, Mario; Delgado, Griselda; Disalvo, Liliana

    2014-03-01

    Prenatal lead exposure is a health hazard that may cause cognitive development impairments and other adverse effects in children. We conducted a cross sectional study analyzing cord blood lead levels (CBLL) of newborns and their relationship with maternal determinants of lead exposure. Mothers answered a questionnaire about socio-demographic, lifestyle habits and environmental characteristics. We used Mann-Whitney's test to compare CBLL geometrical means (GM) corresponding to the presence or absence of each lead exposure determinant, and Chi square test to study the relationship between CBLL and maternal lead exposure determinants. A total of 159 newborns participated in the study. CBLL GM was 2.1 μg/dL; and 25% of the participants had a measurable CBLL (LOQ=3.3 μg/dl). Although the participants had several determinants of lead exposure, we only found a significant relationship with inside household determinants, such as presence of lead piping (p=0.026), unplastered walls (p=0.046) and peeling paint (p=0.048). Our results show that CBLL GM was similar to that reported in several studies conducted around the world. However, 25% of the participants might have some degree of risk for lead poisoning. Copyright © 2013 Elsevier B.V. All rights reserved.

  20. Lead isotopes in soils near five historic American lead smelters and refineries

    International Nuclear Information System (INIS)

    Rabinowitz, Michael B.

    2005-01-01

    This survey of soil lead in the vicinity of old industrial sites examines how the stable isotope patterns vary among the sites according to the sources of the lead ore processed at each site. Lead smelters and refineries, which closed down decades ago, are the basis of this investigation. Samples were taken from near five old factory sites in Collinsville and Alton (Illinois), Ponderay (Idaho), East Chicago (Indiana) and Omaha (Nebraska). Historical records were searched for accounts of the sources of the lead. Lead concentrations were measured by atomic absorption flame spectrophotometry, and stable isotopic analysis was done by plasma ionization mass spectrometry. At every site visited, remnants of the old factories, in terms of soil lead pollution, could be found. In spite of potential complications of varying smelter feedstock sourced from mines of different geological age, it was possible to match the isotopic patterns in the soils with the documented sources of the ores. The Collinsville and Alton sites resembled Missouri lead. The Ponderay value was higher than major Bunker Hill, Idaho deposits, but closer to the minor, nearby Oreille County, Washington ores. Mostly Utah ore was used in East Chicago. The Omaha soil reflects lead from Mexico, Colorado and Montana

  1. Stable lead isotope compositions in selected coals from around the world and implications for present day aerosol source tracing

    Energy Technology Data Exchange (ETDEWEB)

    M. Diaz-Somoano; M.E. Kylander; M.A. Lopez-Anton; I. Suarez-Ruiz; M.R. Martinez-Tarazona; M. Ferrat; B. Kober; D.J. Weiss [Instituto Nacional del Carbon (INCAR-CSIC), Oviedo (Spain)

    2009-02-15

    The phasing out of leaded gasoline in many countries around the world at the end of the last millennium has resulted in a complex mixture of lead sources in the atmosphere. Recent studies suggest that coal combustion has become an important source of Pb in aerosols in urban and remote areas. Lead concentration and isotopic composition is reported for 59 coal samples representing major coal deposits worldwide in an attempt to characterize this potential source. The average concentration in these coals is 35 {mu}g Pb g{sup -1}, with the highest values in coals from Spain and Peru and the lowest in coals from Australia and North America. The {sup 206}Pb/{sup 207}Pb isotope ratios range between 1.15 and 1.24, with less radiogenic Pb in coals from Europe and Asia compared to South and North America. Comparing the Pb isotopic signatures of coals from this and previous studies with those published for Northern and Southern Hemisphere aerosols, we hypothesize that coal combustion might now be an important Pb source in China, the eastern U.S., and to some extent, in Europe but not as yet in other regions including South Africa, South America, and western U.S. This supports the notion that 'old Pb pollution' from leaded gasoline reemitted into the atmosphere or long-range transport (i.e., from China to the western U.S.) is important. Comparing the isotope ratios of the coals, the age of the deposits, and Pb isotope evolution models for the major geochemical reservoirs suggests that the lead isotope ratios (PbIC) in coals is strongly influenced by the depositional coal forming environment. 47 refs., 3 figs., 1 tab.

  2. Guidelines for the Detection and Management of Lead Poisoning for Physicians and Health Care Providers.

    Science.gov (United States)

    Illinois State Dept. of Public Health, Springfield.

    These Illinois guidelines provide information on the medical management and treatment of children with lead poisoning, based on Federal guidelines (revised in 1991) for determining lead poisoning at lower levels. The guidelines outline the effects of lead poisoning, sources of lead, estimated incidence of lead poisoning in Illinois, screening…

  3. A rapid method for simultaneous determination of arsenic, cadmium and lead in drinking water by inductively coupled plasma mass spectrometry

    Directory of Open Access Journals (Sweden)

    Joshua Rey P. Torres

    Full Text Available The raw water source of drinking water in most areas in the Philippines is typically river water and in some cases groundwater. These sources are prone to elevated levels of metals and metalloids that may cause exposure of the general population when the treatment of the water is inadequate. This work presents a simple method based on EPA Method 200.8 for the determination of total concentrations of arsenic (As, cadmium (Cd and lead (Pb in drinking water using inductively coupled plasma-mass spectrometry (ICP-MS as the element-selective detector. This was applied in the determination of these elements in the water supply in Metro Manila, Philippines. The method detection limits were 0.095 μg L-1, 0.043 μg L-1, and 0.114 μg L-1 for total As, Cd and Pb, respectively.The method was validated using National Institute of Standards and Technology (NIST 1643e certified reference material for trace elements in water and determined values were 60.4 ± 0.5 μg L-1, 6.7 ± 0.1 μg L-1, and 19.6 ± 0.5 μg L-1 for As, Cd and Pb, respectively. These determined values were in good agreement with the certified values in the reference material. Analysis of actual drinking water samples showed that most samples did not exceed the limit of the Philippine drinking water standard for the elements.

  4. Experimental study using of a G-M counter and "1"3"7Cs source to measure the HVL with lead

    International Nuclear Information System (INIS)

    Kwon, Dae Cheol; Dong, Kyung Rae

    2016-01-01

    HVL(half-value layer) of lead was measured experimentally using a lead and "1"3"7Cs (370 kBq) source and a G-M counter in which is used a lot of material for shielding HVL measured. "1"3"7Cs in holder to 10 cm and start measuring the radiation. Continue addition of lead of the lead thickness of 1 mm one by one to continue the measurement. By measuring four times the natural radiation of 100 seconds and records the count value and the average rate to be displayed on the meter. Background radiation was a 4 times a count rate and the average 108 (100 s"-"1) as a result of measuring the average measurement, the standard deviation was determined to be 1.08 (s"-"1). An increase in the thickness of lead initial count rate starting from 920 (N) count rate is decreased with increase in the thickness of lead. Net counting rate, starting with the initial 8.12 (s"-"1) showed a decrease with increasing thickness, the standard deviation of the results was decreased from 0.303 (s"-"1) to 0.196 (s"-"1). Net counting rate is reduced to obtain the result that each half thickness of nappan about 7 mm. Was reduced similarly to the exponential function graph correlation coefficient (R"2) was found to be 0.9869. Half-value layer which is the initial net counting rate 7.514 (s"-"1) is a half the 7 mm to 3.757 (s"-"1). In conclusion, it was confirmed the theoretical HVL of lead 7.19 mm and experimentally measured results matched the measured HVL 7 mm

  5. Method of analysis for the determination of lead and cadmium in fresh meat

    NARCIS (Netherlands)

    Ruig, de W.G.

    1980-01-01

    This report comprises the result of the RIKILT of an intercomparison on the determination of lead and cadmium in bovine liver and bovine kidney. The aim of this round robbin was to check a wet ashing procedure followed by a flame AAS determination as described too in EEC doc. 2266/VI/77. Special

  6. Application of proton-induced X-ray emission method to determination of lead content in blood

    International Nuclear Information System (INIS)

    Slominska, D.; Jarczyk, L.; Rokita, E.; Strzalkowski, A.; Losiowski, A.; Macheta, A.; Sych, M.; Moszkowicz, S.

    1979-01-01

    The proton induced X-ray emission method is applied for determination of lead content in the blood of the people exposed to contact with ethyline vapours and people working in lead-zinc works. (author)

  7. Preconcentration system for cadmium and lead determination in environmental samples using polyurethane foam/Me-BTANC

    International Nuclear Information System (INIS)

    Moreira Gama, Ednilton; Silva Lima, Adriana da; Azevedo Lemos, Valfredo

    2006-01-01

    In this work, polyurethane foam (PUF) loaded with 2-(6'-methyl-2'-benzothiazolylazo)chromotropic acid (Me-BTANC) was packed in a minicolumn and it was used in an on-line preconcentration system for cadmium and lead determination. Optimum hydrodynamic and chemical conditions for metal sorption were investigated. The effects of several foreign substances on the adsorption of cadmium and lead were also reported. The enrichment factor obtained was 37 (Cd and Pb) for 180 s preconcentration time. The proposed procedures allowed the determination of metals with detection limits (3σ) of 0.80 and 3.75 μg L -1 (0.10 and 0.47 μg g -1 of solid sample) for cadmium and lead, respectively. The precision of the procedures was also calculated: 3.1 (Cd 10 μg L -1 ) and 4.4% (Pb 100 μg L -1 ). The accuracy of the procedure was checked by analysis of the certified reference materials Spinach Leaves and Fish Tissue. Cadmium and lead contents in environmental samples (black tea, spinach leaves, natural and tap water) were determined by applying the proposed procedure

  8. Factors Associated With Elevated Blood Lead Levels in Children.

    Science.gov (United States)

    Chaudhary, Sakshi; Firdaus, Uzma; Ali, Syed Manazir; Mahdi, Abbas Ali

    2018-01-15

    To determine the prevalence and correlates of elevated blood lead level in children (6-144 months) of Aligarh. A hospital-based cross-sectional study was conducted. Venous blood was obtained for lead estimation and a structured questionnaire was filled. A total of 260 children were enrolled. The prevalence of elevated blood lead level was 44.2%, seen mostly in children below 5 years of age. Old and deteriorating wall paints at home was found to be significantly associated with elevated levels. Lead-based house paints are potential source of lead exposure. Meticulous renovation and painting of the walls with safe paints is desirable.

  9. Chandra Source Catalog: Background Determination and Source Detection

    Science.gov (United States)

    McCollough, Michael L.; Rots, A. H.; Primini, F. A.; Evans, I. N.; Glotfelty, K. J.; Hain, R.; Anderson, C. S.; Bonaventura, N. R.; Chen, J. C.; Davis, J. E.; Doe, S. M.; Evans, J. D.; Fabbiano, G.; Galle, E.; Gibbs, D. G.; Grier, J. D.; Hall, D. M.; Harbo, P. N.; He, X.; Houck, J. C.; Karovska, M.; Lauer, J.; McDowell, J. C.; Miller, J. B.; Mitschang, A. W.; Morgan, D. L.; Nichols, J. S.; Nowak, M. A.; Plummer, D. A.; Refsdal, B. L.; Siemiginowska, A. L.; Sundheim, B. A.; Tibbetts, M. S.; Van Stone, D. W.; Winkelman, S. L.; Zografou, P.

    2009-01-01

    The Chandra Source Catalog (CSC) is a major project in which all of the pointed imaging observations taken by the Chandra X-Ray Observatory will used to generate the most extensive X-ray source catalog produced to date. Early in the development of the CSC it was recognized that the ability to estimate local background levels in an automated fashion would be critical for essential CSC tasks such as source detection, photometry, sensitivity estimates, and source characterization. We present a discussion of how such background maps are created directly from the Chandra data and how they are used in source detection. The general background for Chandra observations is rather smoothly varying, containing only low spatial frequency components. However, in the case of ACIS data, a high spatial frequency component is added that is due to the readout streaks of the CCD chips. We discuss how these components can be estimated reliably using the Chandra data and what limitations and caveats should be considered in their use. We will discuss the source detection algorithm used for the CSC and the effects of the background images on the detection results. We will also touch on some the Catalog Inclusion and Quality Assurance criteria applied to the source detection results. This work is supported by NASA contract NAS8-03060 (CXC).

  10. Determination of stable isotope ratio of lead in airborne particulate matter by ICP-MS

    International Nuclear Information System (INIS)

    Mukai, Hitoshi; Ambe, Yoshinari

    1990-01-01

    ICP-MS was applied to the measurement of stable isotope ratios of lead, which are used as an indicator of the source of lead in airborne particulate matter. For the measurement of lead isotopes ratios, the influences of machine conditions, lead concentration and matrix elements to the precision and accuracy of the measurements were studied. At a scanning mode, dwell time of 40∼160 μs gave the best precision to the isotope ratio measurements; about 0.3 % of R.S.D. for 206 Pb/ 207 Pb and 206 Pb/ 208 Pb, 0.6 % for 206 Pb/ 204 Pb. Precision of the measurement was better at a high concentration of lead in sample solution. The observed value of 206 Pb/ 207 Pb ratio was not affected by the lead concentration, but in the cases of 206 Pb/ 204 Pb and 206 Pb/ 208 Pb, about 1 % of the value changed in the observed ratios with the lead concentration of 100∼500 μg/l. Six matrix elements (Na, K, Ca, Mg, Al, Fe) did not affect the observed isotope ratios up to 200 mg/l. The lead isotope ratios of reference materials {Urban Particulates (NIST) and Vehicle Exhausted Particulates (NIES)} were measured by using two kinds of sample; crude sample and lead-isolated sample from matrix elements by anodic deposition. Both cases gave the same isotope ratio values, therefore, lead isotope ratios in airborne particulate samples can be measured by ICP-MS without any separation of lead from matrix elements. (author)

  11. Determination of the Regional Economy Leading Sectors in Indonesia

    Directory of Open Access Journals (Sweden)

    Fitri Amalia

    2015-03-01

    Full Text Available Economic growth and its process are the main condition for the sustainability of the regional economic development. Because of the continuing population growth means economic needs also increase so that additional revenue required each year. This can be obtained by the increase in aggregate output (goods and services or the Gross Regional Domestic Product (GRDP each year. To carry out development with limited resources as a consequence should be focused to develop the sectors that provide great multiplier effect on other sectors or the whole economy. This research is focused to determine the regional leading sector of Bone Bolango as the information and considerations in planning economic development. Location Quotient (LQ and Shift Share are tools of analysis. Location Quotient analysis indicates agriculture, manufacture, finance, leasing and corporate services are base sectors in the Bone Bolango district. Shift Share analysis indicates that the competitive sectors are finance, leasing and corporate services. The results of the analysis based on three analysis tools indicate that the leading sector with the criteria developed, base, and competitive is finance and services sector.

  12. Automated Determination of Magnitude and Source Length of Large Earthquakes

    Science.gov (United States)

    Wang, D.; Kawakatsu, H.; Zhuang, J.; Mori, J. J.; Maeda, T.; Tsuruoka, H.; Zhao, X.

    2017-12-01

    Rapid determination of earthquake magnitude is of importance for estimating shaking damages, and tsunami hazards. However, due to the complexity of source process, accurately estimating magnitude for great earthquakes in minutes after origin time is still a challenge. Mw is an accurate estimate for large earthquakes. However, calculating Mw requires the whole wave trains including P, S, and surface phases, which takes tens of minutes to reach stations at tele-seismic distances. To speed up the calculation, methods using W phase and body wave are developed for fast estimating earthquake sizes. Besides these methods that involve Green's Functions and inversions, there are other approaches that use empirically simulated relations to estimate earthquake magnitudes, usually for large earthquakes. The nature of simple implementation and straightforward calculation made these approaches widely applied at many institutions such as the Pacific Tsunami Warning Center, the Japan Meteorological Agency, and the USGS. Here we developed an approach that was originated from Hara [2007], estimating magnitude by considering P-wave displacement and source duration. We introduced a back-projection technique [Wang et al., 2016] instead to estimate source duration using array data from a high-sensitive seismograph network (Hi-net). The introduction of back-projection improves the method in two ways. Firstly, the source duration could be accurately determined by seismic array. Secondly, the results can be more rapidly calculated, and data derived from farther stations are not required. We purpose to develop an automated system for determining fast and reliable source information of large shallow seismic events based on real time data of a dense regional array and global data, for earthquakes that occur at distance of roughly 30°- 85° from the array center. This system can offer fast and robust estimates of magnitudes and rupture extensions of large earthquakes in 6 to 13 min (plus

  13. Influence of uranium and lead upon vegetation

    Energy Technology Data Exchange (ETDEWEB)

    Stoklasa, M J

    1913-01-01

    Experiments were performed to determine the effects of radioactive waters on the growth and production of vegetables. Results show that small amounts of radioactive uranium, lead, and radium have a beneficial effect upon the germination and growth of plants. Although uranium is the strongest source of energy, it had less effect than radium.

  14. Lead and lead-based alloys as waste matrix materials

    International Nuclear Information System (INIS)

    Arustamov, A.E.; Ojovan, M.I.; Kachalov, M.B.

    1999-01-01

    Metals and alloys with relatively low melting temperatures such as lead and lead-based alloys are considered in Russia as prospective matrices for encapsulation of spent nuclear fuel in containers in preparation for final disposal in underground repositories. Now lead and lead-based alloys are being used for conditioning spent sealed radioactive sources at radioactive waste disposal facilities

  15. Induced Radioactivity in Lead Shielding at the National Synchrotron Light Source.

    Science.gov (United States)

    Ghosh, Vinita J; Schaefer, Charles; Kahnhauser, Henry

    2017-06-01

    The National Synchrotron Light Source (NSLS) at Brookhaven National Laboratory was shut down in September 2014. Lead bricks used as radiological shadow shielding within the accelerator were exposed to stray radiation fields during normal operations. The FLUKA code, a fully integrated Monte Carlo simulation package for the interaction and transport of particles and nuclei in matter, was used to estimate induced radioactivity in this shielding and stainless steel beam pipe from known beam losses. The FLUKA output was processed using MICROSHIELD® to estimate on-contact exposure rates with individually exposed bricks to help design and optimize the radiological survey process. This entire process can be modeled using FLUKA, but use of MICROSHIELD® as a secondary method was chosen because of the project's resource constraints. Due to the compressed schedule and lack of shielding configuration data, simple FLUKA models were developed. FLUKA activity estimates for stainless steel were compared with sampling data to validate results, which show that simple FLUKA models and irradiation geometries can be used to predict radioactivity inventories accurately in exposed materials. During decommissioning 0.1% of the lead bricks were found to have measurable levels of induced radioactivity. Post-processing with MICROSHIELD® provides an acceptable secondary method of estimating residual exposure rates.

  16. Elevated blood lead levels associated with illegally distilled alcohol.

    Science.gov (United States)

    Pegues, D A; Hughes, B J; Woernle, C H

    1993-06-28

    Whiskey produced in illegal stills (ie, "moonshine") remains an important and underappreciated source of lead toxicity in some rural counties of the Southeast. From March 5 through October 26, 1991, eight adult patients with elevated blood lead levels were identified at a rural county hospital in Alabama and were reported to the Alabama Department of Public Health notifiable disease surveillance system. A case-patient was defined as any person 17 years of age or more who presented to the hospital from January 1, 1990, through December 31, 1991, and had a blood lead level of 0.72 mumol/L or more (15 micrograms/dL or more). To identify cases and potential sources of lead exposure, we reviewed medical and laboratory records from the hospital, interviewed patients with elevated blood lead levels, and determined the lead content of moonshine samples. Nine patients met the case definition, including one patient who was not reported to the state. Patients ranged in age from 28 to 62 years; blood lead values ranged from 0.77 to 12.50 mumol/L (16 to 259 micrograms/dL). The most frequent signs of possible lead toxicity included seizures (six), microcytic anemia (five), and encephalopathy (two); one patient died. The only identified source of lead exposure for the nine patients was moonshine ingestion. Moonshine samples available from local stills contained sufficient amounts of lead (340 to 4600 mumol/L) to result in the observed blood lead levels. This investigation emphasizes the adverse health effects and ongoing public health impact of moonshine ingestion.

  17. Environmental lead hazard to children.

    Science.gov (United States)

    Mittal, S K

    1992-01-01

    Clinically evident lead poisoning is rare in Indian children but is more common than in adults. In children, lead poisoning may appear as fever, seizures, anemia, or abdominal pain, while in adults it is more likely to manifest as chronic minor peripheral neuropathy or gum pigmentation. Children with acute lead poisoning can be treated with chelators such as EDTA and BAL, but many are left with permanent brain damage. The most common sources of acute lead poisoning in Indian children are inhalation of fumes from burned car batteries, ingestion of flaking paint, consuming food cooked in cheap aluminum or brass utensils, and eating contaminated soil. The sources of chronic lead poisoning are water from lead pipes and fumes from industrial or automotive exhaust. Another common source in India is application of "kajjal" to children's eyes. Sources of lead in Western countries, such as drinking water, canned food, residential paint, automotive fuel, and ambient air quality, are regulated by law. None of these are regulated in India.

  18. Determination of Key Risk Supervision Areas around River-Type Water Sources Affected by Multiple Risk Sources: A Case Study of Water Sources along the Yangtze’s Nanjing Section

    Directory of Open Access Journals (Sweden)

    Qi Zhou

    2017-02-01

    Full Text Available To provide a reference for risk management of water sources, this study screens the key risk supervision areas around river-type water sources (hereinafter referred to as the water sources threatened by multiple fixed risk sources (the risk sources, and establishes a comprehensive methodological system. Specifically, it comprises: (1 method of partitioning risk source concentrated sub-regions for screening water source perimeter key risk supervision areas; (2 approach of determining sub-regional risk indexes (SrRI, which characterizes the scale of sub-regional risks considering factors like risk distribution intensity within sub-regions, risk indexes of risk sources (RIRS, characterizing the risk scale of risk sources and the number of risk sources; and (3 method of calculating sub-region’s risk threats to the water sources (SrTWS which considers the positional relationship between water sources and sub-regions as well as SrRI, and the criteria for determining key supervision sub-regions. Favorable effects are achieved by applying this methodological system in determining water source perimeter sub-regions distributed along the Yangtze’s Nanjing section. Results revealed that for water sources, the key sub-regions needing supervision were SD16, SD06, SD21, SD26, SD15, SD03, SD02, SD32, SD10, SD11, SD14, SD05, SD27, etc., in the order of criticality. The sub-region with the greatest risk threats on the water sources was SD16, which was located in the middle reaches of Yangtze River. In general, sub-regions along the upper Yangtze reaches had greater threats to water sources than the lower reach sub-regions other than SD26 and SD21. Upstream water sources were less subject to the threats of sub-regions than the downstream sources other than NJ09B and NJ03.

  19. Source apportionment and environmental fate of lead chromates in atmospheric dust in arid environments.

    Science.gov (United States)

    Meza-Figueroa, Diana; González-Grijalva, Belem; Romero, Francisco; Ruiz, Joaquin; Pedroza-Montero, Martín; Rivero, Carlos Ibañez-Del; Acosta-Elías, Mónica; Ochoa-Landin, Lucas; Navarro-Espinoza, Sofía

    2018-03-07

    The environmental fate of lead derived from traffic paint has been poorly studied in developing countries, mainly in arid zones. For this purpose, a developing city located in the Sonoran desert (Hermosillo, Mexico), was chosen to conduct a study. In this paper the lead chromate (crocoite) sources in atmospheric dust were addressed using a combination of Raman microspectroscopy, X-ray diffraction, scanning electron microscopy (SEM), and Pb isotope measurements. A high concentration of Pb and Cr as micro- and nanostructured pigments of crocoite is reported in yellow traffic paint (n=80), road dust (n=146), settled dust in roofs (n=21), and atmospheric dust (n=20) from a developing city located in the Sonoran Desert. 10 samples of peri-urban soils were collected for local geochemical background. The paint photodegradation and erosion of the asphaltic cover are enhanced by the climate, and the presence of the mineral crocoite (PbCrO 4 ) in road dust with an aerodynamic diameter ranging from 100nm to 2μm suggests its integration into the atmosphere by wind resuspension processes. A positive PbCr correlation (R 2 =0.977) was found for all studied samples, suggesting a common source. The Pb-isotope data show signatures in atmospheric dust as a product of the mixing of two end members: i) local soils and ii) crocoite crystals as pigments in paint. The presence of lead chromates in atmospheric dust has not been previously documented in Latin America, and it represents an unknown health risk to the exposed population because the identified size of crystals can reach the deepest part of lungs. Copyright © 2018 Elsevier B.V. All rights reserved.

  20. High Burden of Subclinical Lead Toxicity after Phase Out of Lead from Petroleum in Pakistan.

    Science.gov (United States)

    Majid, Hafsa; Khan, Aysha Habib; Khan, Nadeem Ullah; Siddiqui, Imran; Ghani, Farooq; Jafri, Lena

    2017-12-01

    To evaluate the frequency of subclinical lead toxicity. Cross-sectional study. Department of Pathology and Laboratory Medicine, The Aga Khan University Hospital, Karachi, from January 2011 to December 2014. Analysis of laboratory data for blood lead levels (BLL) was performed. Lead was tested by atomic absorption spectrometer. For all subjects, only initial test results were included while the results of repeated testing were excluded. Exemption was sought from institutional ethical review committee. BLL of 2-10 ug/dl and 10-70 ug/dl in children and adults, respectively were taken as subclinical lead toxicity. Amongst the total number of subjects tested (n=524), 26.5% (n=139) were children (lead level 16.9 ug/dl (36.1-4)] and lower level [4.2 ug/dl (6.8-2.6)] in children with lead levels while most had either subclinical (76%, n=106) or toxic lead levels (8%, n=11). In adults, (55%, n=212) subjects had desired lead levels, and 40% (n=154) and 4.99% (n=19) had subclinical and toxic lead levels. Presence of subclinical lead poisoning even after phasing out of lead petroleum in Pakistanis is alarming, especially in children. A national population-based study to determine the lead status and targeted intervention to identify potential sources is need of the time.

  1. The determination of aluminum, copper, iron, and lead in glycol formulations by atomic absorption spectroscopy

    Science.gov (United States)

    1977-01-01

    Initial screening tests and the results obtained in developing procedures to determine Al, Cu, Fe, and Pb in glycol formulations are described. Atomic absorption completion was selected for Cu, Fe and Pb, and after comparison with emission spectroscopy, was selected for Al also. Before completion, carbon, iron, and lead are extracted with diethyl dithio carbamate (DDC) into methyl isobutyl ketone (MIBK). Aluminum was also extracted into MIBK using 8-hydroxyquinoline as a chelating agent. As little as 0.02 mg/l carbon and 0.06 mg/l lead or iron may be determined in glycol formulations. As little as 0.3 mg/l aluminum may be determined.

  2. ETAAS determination of thallium and silver from water matrix after colloidal precipitate flotation using lead(II hexamethylenedithiocarbamate

    Directory of Open Access Journals (Sweden)

    TRAJCE STAFILOV

    2001-10-01

    Full Text Available Afast method for the preconcentration of thallium and silver in nanogram quantities in fresh drinking waters (source, well, tap and waters for irrigation using colloidal precipitate flotation is described. Lead(II hexamethylenedithiocarbamate, Pb(HMDTC2 played the role of flotation collector. The experimental conditions for the successful separation of thallium and silver (mass of Pb, amount ofHMDTC-, pHof the system, induction time, type of surfactant etc. were optimized. After flotation separation from the mother liquor, the solid sublate containing traces of thallium and silver was dissolved and the analytes were determined by electrothermal atomic absorption spectrometry (ETAAS. The results of the ETAAS analysis are compared with those obtained by inductively coupled plasma-atomic emission spectrometry. The detection limit for thallium by this method is 0.027 mg/l, and for silver 0.005 microg/l.

  3. Environmental lead pollution threatens the children living in the Pearl River Delta region, China.

    Science.gov (United States)

    Chen, Jianmin; Tong, Yongpeng; Xu, Jiazhang; Liu, Xiaoli; Li, Yulan; Tan, Mingguang; Li, Yan

    2012-09-01

    The objective of this study is to determine children's blood lead levels and identify sources of lead exposure. Childhood lead exposure constitutes a major pediatric health problem today in China. A blood lead screening survey program for children in the age group of 2-12 years residing in Pearl River Delta region, south of China, was carried out from Dec 2007 to Jan 2008. Blood lead levels and lead isotope ratios of a total of 761 participants were assessed by inductively coupled plasma mass spectroscopy. Measurements of urban environmental samples for source identification of children lead exposure were also performed. The geometric mean value of the children's blood lead levels was 57.05 μg/L, and 9.6% of them were higher than 100 μg/L. The blood lead levels were still much higher than those in developed countries. Based on the data of environmental lead source inventories, lead isotopic tracing revealed that there is about 6.7% past used gasoline Pb embedded in Shenzhen residential dust and about 15.6% in Guangzhou dust, respectively.

  4. Lead contamination and transfer in urban environmental compartments analyzed by lead levels and isotopic compositions

    International Nuclear Information System (INIS)

    Hu, Xin; Sun, Yuanyuan; Ding, Zhuhong; Zhang, Yun; Wu, Jichun; Lian, Hongzhen; Wang, Tijian

    2014-01-01

    Lead levels and isotopic compositions in atmospheric particles (TSP and PM 2.5 ), street dust and surface soil collected from Nanjing, a mega city in China, were analyzed to investigate the contamination and the transfer of lead in urban environmental compartments. The lead contents in TSP and PM 2.5 are significantly higher than them in the surface soil and street dust (p  206 Pb/ 207 Pb vs. 208 Pb/ 206 Pb and 206 Pb/ 207 Pb vs. 1/Pb imply that the street dust and atmospheric particles (TSP and PM 2.5 ) have very similar lead sources. Coal emissions and smelting activities may be the important lead sources for street dust and atmospheric particles (TSP and PM 2.5 ), while the deposition of airborne lead is an important lead source for urban surface soil. - Highlights: • Lead levels and isotope ratios in atmospheric particles, street dust and surface soil. • Significant enrichment of lead in atmospheric particles was observed. • Street dust and atmospheric particles have similar lead sources. • Endmembers of soil lead differ from street dust and atmospheric particles. • Airborne lead poses the main risks to unban environmental quality. - Transfer of airborne particle bound lead into street dust and surface soil in unban environmental based on lead levels and isotopic compositions

  5. Environmental determinants of different blood lead levels in children: a quantile analysis from a nationwide survey.

    Science.gov (United States)

    Etchevers, Anne; Le Tertre, Alain; Lucas, Jean-Paul; Bretin, Philippe; Oulhote, Youssef; Le Bot, Barbara; Glorennec, Philippe

    2015-01-01

    Blood lead levels (BLLs) have substantially decreased in recent decades in children in France. However, further reducing exposure is a public health goal because there is no clear toxicological threshold. The identification of the environmental determinants of BLLs as well as risk factors associated with high BLLs is important to update prevention strategies. We aimed to estimate the contribution of environmental sources of lead to different BLLs in children in France. We enrolled 484 children aged from 6months to 6years, in a nationwide cross-sectional survey in 2008-2009. We measured lead concentrations in blood and environmental samples (water, soils, household settled dusts, paints, cosmetics and traditional cookware). We performed two models: a multivariate generalized additive model on the geometric mean (GM), and a quantile regression model on the 10th, 25th, 50th, 75th and 90th quantile of BLLs. The GM of BLLs was 13.8μg/L (=1.38μg/dL) (95% confidence intervals (CI): 12.7-14.9) and the 90th quantile was 25.7μg/L (CI: 24.2-29.5). Household and common area dust, tap water, interior paint, ceramic cookware, traditional cosmetics, playground soil and dust, and environmental tobacco smoke were associated with the GM of BLLs. Household dust and tap water made the largest contributions to both the GM and the 90th quantile of BLLs. The concentration of lead in dust was positively correlated with all quantiles of BLLs even at low concentrations. Lead concentrations in tap water above 5μg/L were also positively correlated with the GM, 75th and 90th quantiles of BLLs in children drinking tap water. Preventative actions must target household settled dust and tap water to reduce the BLLs of children in France. The use of traditional cosmetics should be avoided whereas ceramic cookware should be limited to decorative purposes. Copyright © 2014 Elsevier Ltd. All rights reserved.

  6. Lead determination in uranium mineralization soils by atomic absorption spectrometry with graphite oven

    International Nuclear Information System (INIS)

    Teixeira, Gleber Tacio

    2001-01-01

    The contamination of soils by lead has a great environmental importance due to its toxicity to vegetables, animals and humans. In general, the mobility of the lead is small due to its low solubility and strong adsorption in the soil. However, its solubility can be altered by several conditions (pH, redox potential and ionic stronger). Consequently, lead can migrate through the soil and can contaminate superficial and underground waters. The objective of this work was to determine the concentration of total lead in soil samples with uranium mineralization, in an area at Ipora/GO, having been evaluated as economically insuitable the extraction of that mineral. The radiogenic lead appears as a product of natural radioactive elements decay. In the decay series of uranium-238 we found the isotope lead-214 (half-life of 26,8 min), lead-210 (half-life of 22,3 min), and lead-206 that is stable. The sampling was done in profiles around north, south, east and west directions, starting from a reference point (FT), chosen by presenting the largest radiation of that place (4800 cps). A mass of 1 Kg of superficial soil was collected to each 20 m, in each profile, until 150 m of FT. Approximately, 1 g of dry soil, fraction 2 mm, was digested with a mixture of acids HNO 3 /HClO 4 2:1 (v/v), and the resulting solution was analyzed by atomic absorption. An atomic absorption spectrometer was used with graphite furnace, with deuterium arc to background correction and pyrolytic coated tube. Phosphoric acid was used as chemical modifier. The obtained results, using the standard additions method, presented a decrease of the lead concentration, in all profiles, when the distance of FT was increased. It was also made a radiometric screening in each sampling point. The lead concentration variate from 115,1 μg.g -1 in FT, to less than 40 μg.g -1 at 150 m of distance of FT ( 3 ) 2 was used. The method was applied to a certified sample, showing a good agreement between certified and

  7. Determination of lead and cadmium in urine by electrothermal atomization atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Vasil'eva, L.A.; Grinshtejn, I.L.; Gucher, Sh.; Izgi, B.

    2008-01-01

    The applicability of a DETATA sorbent to the preconcentration of lead and cadmium followed by the determination of these elements in urine using atomic absorption spectrometry with electrothermal atomization was demonstrated. After preconcentration by a factor of 10, the limits of detection were 0.01 and 0.2 μg/l for cadmium and lead, respectively. The accuracy of the results was supported by the analysis of Seronorm TM Trace Elements Urine Batch no.101021 [ru

  8. Potential containment materials for liquid-lead and lead-bismuth eutectic spallation neutron source

    International Nuclear Information System (INIS)

    Park, J.J.; Butt, D.P.; Beard, C.A.

    1997-11-01

    Lead (Pb) and lead-bismuth eutectic (44Pb-56Bi) have been the two primary candidate liquid-metal target materials for the production of spallation neutrons. Selection of a container material for the liquid-metal target will greatly affect the lifetime and safety of the target subsystem. For the lead target, niobium-1 (wt%) zirconium (Nb-1Zr) is a candidate containment material for liquid lead, but its poor oxidation resistance has been a major concern. The oxidation rate of Nb-1Zr was studied based on the calculations of thickness loss due to oxidation. According to these calculations, it appeared that uncoated Nb-1Zr may be used for a one-year operation at 900 C at P O 2 = 1 x 10 -6 torr, but the same material may not be used in argon with 5-ppm oxygen. Coating technologies to reduce the oxidation of Nb-1Zr are reviewed, as are other candidate refractory metals such as molybdenum, tantalum, and tungsten. For the Pb-Bi target, three candidate containment materials are suggested based on a literature survey of the materials compatibility and proton irradiation tests: Croloy 2-1/4, modified 9Cr-1Mo, and 12Cr-1Mo (HT-9) steel. These materials seem to be used only if the lead-bismuth is thoroughly deoxidized and treated with zirconium and magnesium

  9. Determination of 0.01–0.1% of samarium in 40–100 mg of lead chloride

    NARCIS (Netherlands)

    Agterdenbos, J.; Jütte, B.A.H.G.; Schuring, J.

    1971-01-01

    A method is described for the determination of 5–25 μg of samarium in about 40 mg of lead chloride, based on the removal of the lead by electrolysis and determination of the samarium by extraction with PAN and measurement of the extinction of the complex at 552 nm.

  10. First studies of lead pollution in Guanabara

    International Nuclear Information System (INIS)

    Silveira Branquinho, C.L. da.

    1973-01-01

    The main sources of direct lead intake are studied, and metal concentrations in several medium are examined. Lead was extracted by dithizone in C Cl 4 , being determined by optical spectrophotometry. 2 1 2 Pb was used as a radioactive tracer in low concentration measurements of the metal, and analysis of its 239 KeV peak was done by a Ge-Li detector. In blood samples, the metal was complexed and extracted with APDC in MIBK, being measured by flame less atomic absorption spectrophotometry. Air samples were also collected for periods of 24 hours and 90 minutes. Representative street dust samples were examined, showing a strict correlation with lead in air. It was also estimated the amount of lead in some human blood samples. (author)

  11. A photon spectrometric dose-rate constant determination for the Advantage Pd-103 brachytherapy source

    International Nuclear Information System (INIS)

    Chen, Zhe Jay; Bongiorni, Paul; Nath, Ravinder

    2010-01-01

    Purpose: Although several dosimetric characterizations using Monte Carlo simulation and thermoluminescent dosimetry (TLD) have been reported for the new Advantage Pd-103 source (IsoAid, LLC, Port Richey, FL), no AAPM consensus value has been established for the dosimetric parameters of the source. The aim of this work was to perform an additional dose-rate constant (Λ) determination using a recently established photon spectrometry technique (PST) that is independent of the published TLD and Monte Carlo techniques. Methods: Three Model IAPD-103A Advantage Pd-103 sources were used in this study. The relative photon energy spectrum emitted by each source along the transverse axis was measured using a high-resolution germanium spectrometer designed for low-energy photons. For each source, the dose-rate constant was determined from its emitted energy spectrum. The PST-determined dose-rate constant ( PST Λ) was then compared to those determined by TLD ( TLD Λ) and Monte Carlo ( MC Λ) techniques. A likely consensus Λ value was estimated as the arithmetic mean of the average Λ values determined by each of three different techniques. Results: The average PST Λ value for the three Advantage sources was found to be (0.676±0.026) cGyh -1 U -1 . Intersource variation in PST Λ was less than 0.01%. The PST Λ was within 2% of the reported MC Λ values determined by PTRAN, EGSnrc, and MCNP5 codes. It was 3.4% lower than the reported TLD Λ. A likely consensus Λ value was estimated to be (0.688±0.026) cGyh -1 U -1 , similar to the AAPM consensus values recommended currently for the Theragenics (Buford, GA) Model 200 (0.686±0.033) cGyh -1 U -1 , the NASI (Chatsworth, CA) Model MED3633 (0.688±0.033) cGyh -1 U -1 , and the Best Medical (Springfield, VA) Model 2335 (0.685±0.033) cGyh -1 U -1 103 Pd sources. Conclusions: An independent Λ determination has been performed for the Advantage Pd-103 source. The PST Λ obtained in this work provides additional information

  12. Lead - nutritional considerations

    Science.gov (United States)

    ... billion people had toxic (poisonous) blood lead levels. Food Sources Lead can be found in canned goods if there is lead solder in the ... to bottled water for drinking and cooking. Avoid canned goods from foreign ... cans goes into effect. If imported wine containers have a lead foil ...

  13. Particulate-bound polycyclic aromatic hydrocarbon sources and determinants in residential homes.

    Science.gov (United States)

    Cattaneo, Andrea; Fermo, Paola; Urso, Patrizia; Perrone, Maria Grazia; Piazzalunga, Andrea; Tarlassi, Jessica; Carrer, Paolo; Cavallo, Domenico Maria

    2016-11-01

    Human exposure to polycyclic aromatic hydrocarbons (PAHs) in indoor environments can be particularly relevant because people spend most of their time inside buildings, especially in homes. This study aimed to investigate the most important particle-bound PAH sources and exposure determinants in PM 2.5 samples collected in 19 homes located in northern Italy. Complementary information about ion content in PM 10 was also collected in 12 of these homes. Three methods were used for the identification of PAH sources and determinants: diagnostic ratios with principal component and hierarchical cluster analyses (PCA and HCA), chemical mass balance (CMB) and linear mixed models (LMMs). This combined and tiered approach allowed the infiltration of outdoor PAHs into indoor environments to be identified as the most important source in winter, with a relevant role played by biomass burning and traffic exhausts to be identified as a general source of PAHs in both seasons. Tobacco smoke exhibited an important impact on PAH levels in smokers' homes, whereas in the whole sample, cooking food and natural gas sources played a minor or negligible role. Nitrate, sulfate and ammonium were the main inorganic constituents of indoor PM 10 owing to the secondary formation of ammonium sulfates and nitrates. Copyright © 2016 Elsevier Ltd. All rights reserved.

  14. Determining profile of dose distribution for PD-103 brachytherapy source

    International Nuclear Information System (INIS)

    Berkay, Camgoz; Mehmet, N. Kumru; Gultekin, Yegin

    2006-01-01

    Full text: Brachytherapy is a particular radiotherapy for cancer treatments. By destructing cancerous cells using radiation, the treatment proceeded. When alive tissues are subject it is hazardous to study experimental. For brachytherapy sources generally are studied as theoretical using computer simulation. General concept of the treatment is to locate the radioactive source into cancerous area of related tissue. In computer studies Monte Carlo mathematical method that is in principle based on random number generations, is used. Palladium radioisotope is LDR (Low radiation Dose Rate) source. Main radioactive material was coated with titanium cylinder with 3mm length, 0.25 mm radius. There are two parts of Pd-103 in the titanium cylinder. It is impossible to investigate differential effects come from two part as experimental. Because the source dimensions are small compared with measurement distances. So there is only simulation method. In dosimetric studies it is aimed to determine absorbed dose distribution in tissue as radial and angular. In nuclear physics it is obligation to use computer based methods for researchers. Radiation studies have hazards for scientist and people interacted with radiation. When hazard exceed over recommended limits or physical conditions are not suitable (long work time, non economical experiments, inadequate sensitivity of materials etc.) it is unavoidable to simulate works and experiments before practices of scientific methods in life. In medical area, usage of radiation is required computational work for cancer treatments. Some computational studies are routine in clinics and other studies have scientific development purposes. In brachytherapy studies there are significant differences between experimental measurements and theoretical (computer based) output data. Errors of data taken from experimental studies are larger than simulation values errors. In design of a new brachytherapy source it is important to consider detailed

  15. Stable isotopes of lead and strontium as tracers of sources of airborne particulate matter in Kyrgyzstan.

    Science.gov (United States)

    Central Asia is dominated by an arid climate and desert-like conditions, leading to the potential of long-range transport of desert dust. One potential source of dust to Central Asia is the Aral Sea, the surface area of which has receded in size from 68,000 km2 to 14,280 km2, lar...

  16. Source term determination from subcritical multiplication measurements at Koral-1 reactor

    International Nuclear Information System (INIS)

    Blazquez, J.B.; Barrado, J.M.

    1978-01-01

    By using an AmBe neutron source two independent procedures have been settled for the zero-power experimental fast-reactor Coral-1 in order to measure the source term which appears in the point kinetical equations. In the first one, the source term is measured when the reactor is just critical with source by taking advantage of the wide range of the linear approach to critical for Coral-1. In the second one, the measurement is made in subcritical state by making use of the previous calibrated control rods. Several applications are also included such as the measurement of the detector dead time, the determinations of the reactivity of small samples and the shape of the neutron importance of the source. (author)

  17. Determination of cadmium, lead and zinc in a candidate reference materials using isotope dilution mass spectrometry

    International Nuclear Information System (INIS)

    Munoz, Luis; Gras, Nuri; Quejido, Alberto; Fernandez, Marta

    2001-01-01

    The growing demands placed on analytical laboratories to ensure the reliability of their results, due to the introduction of systems of quality and to the increasing use of metrology in chemical measurements has led most laboratories to validate their methodologies and to control them statistically. One of the techniques used most often for these purposes is based on the use of reference materials. The proper use of these materials means that laboratory results may be traced to the International System of Units, analytical methodologies can be validated, instruments calibrated and chemical measurements harmonized. One of the biggest challenges in developing reference materials is that of certifying their properties, a process that has been defined as assigning a concentration value that is as close as possible to the true value together with its uncertainty. Organizations that produce reference materials use several options for their certification process, and among these is the use of a primary method. Among the primary methods recognized by the International Office of Weights and Measures is the Isotope Dilution Mass Spectrometry technique. The Chilean Nuclear Energy Commission, through its Reference Materials Program, has prepared a reference material of clam tissue, which has been chemically defined by different analytical methodologies applied in different national and international laboratories. This work describes the methodology developed with the CIEMAT for determining the elements lead, cadmium and zinc in the clam tissue reference material using the primary technique of Isotope Dilution Mass Spectrometry. The calculation is described for obtaining the spike amounts to be added to the sample and the procedure is explained for carrying out the isotopic exchange. The isotopic relationships 204 Pb/ 205 Pb, 111 Cd/ 114 Cd and 66 Zn/ 67 Zn were determined in an atomic emission spectrometer with a plasma source with the following characteristics: plasma

  18. The Chandra Source Catalog : Automated Source Correlation

    Science.gov (United States)

    Hain, Roger; Evans, I. N.; Evans, J. D.; Glotfelty, K. J.; Anderson, C. S.; Bonaventura, N. R.; Chen, J. C.; Davis, J. E.; Doe, S. M.; Fabbiano, G.; Galle, E.; Gibbs, D. G.; Grier, J. D.; Hall, D. M.; Harbo, P. N.; He, X.; Houck, J. C.; Karovska, M.; Lauer, J.; McCollough, M. L.; McDowell, J. C.; Miller, J. B.; Mitschang, A. W.; Morgan, D. L.; Nichols, J. S.; Nowak, M. A.; Plummer, D. A.; Primini, F. A.; Refsdal, B. L.; Rots, A. H.; Siemiginowska, A. L.; Sundheim, B. A.; Tibbetts, M. S.; Van Stone, D. W.; Winkelman, S. L.; Zografou, P.

    2009-01-01

    Chandra Source Catalog (CSC) master source pipeline processing seeks to automatically detect sources and compute their properties. Since Chandra is a pointed mission and not a sky survey, different sky regions are observed for a different number of times at varying orientations, resolutions, and other heterogeneous conditions. While this provides an opportunity to collect data from a potentially large number of observing passes, it also creates challenges in determining the best way to combine different detection results for the most accurate characterization of the detected sources. The CSC master source pipeline correlates data from multiple observations by updating existing cataloged source information with new data from the same sky region as they become available. This process sometimes leads to relatively straightforward conclusions, such as when single sources from two observations are similar in size and position. Other observation results require more logic to combine, such as one observation finding a single, large source and another identifying multiple, smaller sources at the same position. We present examples of different overlapping source detections processed in the current version of the CSC master source pipeline. We explain how they are resolved into entries in the master source database, and examine the challenges of computing source properties for the same source detected multiple times. Future enhancements are also discussed. This work is supported by NASA contract NAS8-03060 (CXC).

  19. Lead contamination and transfer in urban environmental compartments analyzed by lead levels and isotopic compositions.

    Science.gov (United States)

    Hu, Xin; Sun, Yuanyuan; Ding, Zhuhong; Zhang, Yun; Wu, Jichun; Lian, Hongzhen; Wang, Tijian

    2014-04-01

    Lead levels and isotopic compositions in atmospheric particles (TSP and PM2.5), street dust and surface soil collected from Nanjing, a mega city in China, were analyzed to investigate the contamination and the transfer of lead in urban environmental compartments. The lead contents in TSP and PM2.5 are significantly higher than them in the surface soil and street dust (p lead to the major crustal elements (Al, Sr, Ti and Fe) indicates significant lead enrichment in atmospheric particles. The plots of (206)Pb/(207)Pb vs.(208)Pb/(206)Pb and (206)Pb/(207)Pb vs. 1/Pb imply that the street dust and atmospheric particles (TSP and PM2.5) have very similar lead sources. Coal emissions and smelting activities may be the important lead sources for street dust and atmospheric particles (TSP and PM2.5), while the deposition of airborne lead is an important lead source for urban surface soil. Copyright © 2013 Elsevier Ltd. All rights reserved.

  20. Lead isotopes combined with a sequential extraction procedure for source apportionment in the dry deposition of Asian dust and non-Asian dust

    International Nuclear Information System (INIS)

    Lee, Pyeong-Koo; Yu, Soonyoung

    2016-01-01

    Lead isotopic compositions were determined in leachates that were generated using sequential extractions of dry deposition samples of Asian dust (AD) and non-Asian dust (NAD) and Chinese desert soils, and used to apportion Pb sources. Results showed significant differences in "2"0"6Pb/"2"0"7Pb and "2"0"6Pb/"2"0"4Pb isotopic compositions in non-residual fractions between the dry deposition samples and the Chinese desert soils while "2"0"6Pb/"2"0"7Pb and "2"0"6Pb/"2"0"4Pb isotopic compositions in residual fraction of the dry deposition of AD and NAD were similar to the mean "2"0"6Pb/"2"0"7Pb and "2"0"6Pb/"2"0"4Pb in residual fraction of the Alashan Plateau soil. These results indicate that the geogenic materials of the dry deposition of AD and NAD were largely influenced by the Alashan Plateau soil, while the secondary sources of the dry deposition were different from those of the Chinese desert soils. In particular, the lead isotopic compositions in non-residual fractions of the dry deposition were homogenous, which implies that the non-residual four fractions (F1 to F4) shared the primary anthropogenic origin. "2"0"6Pb/"2"0"7Pb values and the predominant wind directions in the study area suggested that airborne particulates of heavily industrialized Chinese cities were one of the main Pb sources. Source apportionment calculations showed that the average proportion of anthropogenic Pb in the dry deposition of AD and NAD was 87% and 95% respectively in total Pb extraction, 92% and 97% in non-residual fractions, 15% and 49% in residual fraction. Approximately 81% and 80% of the anthropogenic Pb was contributed by coal combustion in China in the dry deposition of AD and NAD respectively while the remainder was derived from industrial Pb contamination. The research result proposes that sequential extractions with Pb isotope analysis are a useful tool for the discrimination of anthropogenic and geogenic origins in highly contaminated AD and NAD. - Highlights:

  1. A photon spectrometric dose-rate constant determination for the Advantage Pd-103 brachytherapy source

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Zhe Jay; Bongiorni, Paul; Nath, Ravinder [Department of Therapeutic Radiology, Yale University School of Medicine, New Haven, Connecticut 06520 (United States)

    2010-02-15

    Purpose: Although several dosimetric characterizations using Monte Carlo simulation and thermoluminescent dosimetry (TLD) have been reported for the new Advantage Pd-103 source (IsoAid, LLC, Port Richey, FL), no AAPM consensus value has been established for the dosimetric parameters of the source. The aim of this work was to perform an additional dose-rate constant ({Lambda}) determination using a recently established photon spectrometry technique (PST) that is independent of the published TLD and Monte Carlo techniques. Methods: Three Model IAPD-103A Advantage Pd-103 sources were used in this study. The relative photon energy spectrum emitted by each source along the transverse axis was measured using a high-resolution germanium spectrometer designed for low-energy photons. For each source, the dose-rate constant was determined from its emitted energy spectrum. The PST-determined dose-rate constant ({sub PST}{Lambda}) was then compared to those determined by TLD ({sub TLD}{Lambda}) and Monte Carlo ({sub MC}{Lambda}) techniques. A likely consensus {Lambda} value was estimated as the arithmetic mean of the average {Lambda} values determined by each of three different techniques. Results: The average {sub PST}{Lambda} value for the three Advantage sources was found to be (0.676{+-}0.026) cGyh{sup -1} U{sup -1}. Intersource variation in {sub PST}{Lambda} was less than 0.01%. The {sub PST}{Lambda} was within 2% of the reported {sub MC}{Lambda} values determined by PTRAN, EGSnrc, and MCNP5 codes. It was 3.4% lower than the reported {sub TLD}{Lambda}. A likely consensus {Lambda} value was estimated to be (0.688{+-}0.026) cGyh{sup -1} U{sup -1}, similar to the AAPM consensus values recommended currently for the Theragenics (Buford, GA) Model 200 (0.686{+-}0.033) cGyh{sup -1} U{sup -1}, the NASI (Chatsworth, CA) Model MED3633 (0.688{+-}0.033) cGyh{sup -1} U{sup -1}, and the Best Medical (Springfield, VA) Model 2335 (0.685{+-}0.033) cGyh{sup -1} U{sup -1} {sup 103}Pd

  2. Nondestructive determination of lead, cadmium, tin, antimony, and barium in ceramic glazes by radioisotope X-ray fluorescence spectrometry

    International Nuclear Information System (INIS)

    Anderson, D.L.; Cunningham, W.C.

    1996-01-01

    Quantitation capabilities of radioisotope X-ray fluorescence spectrometry (RXRFS) for determining lead, cadmium, tin, antimony, and barium in ceramic glazes were investigated. Twenty-one air-dried glazes and 85 fired glazes on test tiles were analyzed by using 109 Cd and 57 Co excitation sources. Accurate Pb determinations, with limits of detection (LODs) of about 0.3 mg/cm 2 for 5 min counting times, were achieved by using the 75 keV Κ α1 X-ray photopeak and a Pb foil calibration procedure. Cd, Sn, Sb, and Ba concentrations were determined with LODs from about 0.5 to 1.5 mg/cm 2 . For Pb and Ba, results obtained by using absorption corrections based only on element concentrations determined by RXRFS and an iterative approach led to analytical biases of ≤4% relative to results obtained by using corrections based on known total element compositions. Biases were more severe for Cd, Sn, and Sb because lower X-ray energies were involved and sensitivities varied as a function of matrix Pb content. Pb concentrations were above LODs (1.3-40 mg/cm 2 ) in 39 of 47 fired open-quotes food-safeclose quotes glazes and in 33 of the other 38 fired glazes (0.4-39 mg/cm 2 ). 15 refs., 9 figs., 9 tabs

  3. Automatic on-line pre-concentration system using a knotted reactor for the FAAS determination of lead in drinking water

    International Nuclear Information System (INIS)

    Souza, Anderson S.; Brandao, Geovani C.; Santos, Walter N.L. dos; Lemos, Valfredo A.; Ganzarolli, Edgard M.; Bruns, Roy E.; Ferreira, Sergio L.C.

    2007-01-01

    An automatic on-line pre-concentration system is proposed for lead determination in drinking water using flame atomic absorption spectrometry (FAAS). Lead(II) ions are retained as the 1-(2-pyridylazo)-2-naphthol (PAN) complex in the walls of a knotted reactor, followed by an elution step using 0.50 mol L -1 hydrochloric acid solution. Optimisation involving the sampling flow rate, pH and buffer concentration factors was performed using a Box-Behnken design. Other factors were established considering results of previous experiments. The procedure allows the determination of lead with a 0.43 μg L -1 detection limit (3σ/S) and precisions (expressed as relative standard deviation) of 4.84% (N = 7) and 2.9% (N = 7) for lead concentrations of 5 and 25 μg L -1 , respectively. The accuracy was confirmed by the determination of lead in the NIST SRM 1643d trace elements in natural water standard reference material. The pre-concentration factor obtained is 26.5 and the sampling frequency is 48 h -1 . The recovery achieved for lead determination in the presence of several ions demonstrated that this procedure could be applied to the analysis of drinking water samples. The method was applied for lead determination in drinking water samples collected in Jequie City, Brazil. The lead concentration found in 25 samples were always lower than the permissible maximum levels stipulated by World Health Organization

  4. Lead isotopic characterization of respirable urban aerosols and related sources, Santiago-Chile

    International Nuclear Information System (INIS)

    Diaz, M; Kawashita, K; Antinao, J.L

    2001-01-01

    Santiago de Chile is located in a poorly ventilated valley at 33 o 30' latitude south at an altitude of 550m. Local climate is semi-arid with mean annual rainfall below 350mm. The atmospheric particles constitute one of the main factors of urban air pollution in the city. Morphological characterization of airborne particles of Santiago done by Scanning Electron Microscopy showed the presence of three groups of particles: crystalline. spherical and agglomerate particles. The crystalline shapes originated in geologic sources have perfectly defined crystallographic parameters. The agglomerated shapes are formed by organic material and submicrometrical mineral particles derived from combustion of fossil fuel and the spherical shapes are products of metallurgical activities. Some of them could been associated with the wear of motorcars. Samples of aerosols. sediments and leaded petrol of different distributors were collected. Aerosols were sampled in two sites of Santiago: the Movil monitoring station, at east of the city, and Parque O'Higgins monitoring station in downtown. These two monitoring stations belong to the MACAM network. Sediments of Mapocho, Maipo, San Francisco and Zanjon de la Aguada rivers and two samples from Disputada and Merceditas ores were studied. All the samples have been measured for their 206 Pb/ 204 Pb, 207 Pb/ 204 Pb and 208 Pb/ 204 Pb ratios. The experimental chemical procedures of sample dissolution and Pb separation by anion exchange chromatography were developed in the Sernageomin clean laboratory of Santiago de Chile. The isotopic measurements were made using a VG-Sector isotope ratio mass spectrometer fitted with a thermal ion source, multi Faraday collector and Daly collector of the Isotopic Geology Laboratory in the Universidade Federal de Rio Grande do Sul, Brazil. The measurements were corrected using NBS 981 and 982 standards. Isotopic results plotted in a 208 Pb/ 204 Pb versus 206 Pb/ 204 Pb diagram and in a 207 Pb/ 204 Pb versus

  5. Method of determining paper-deposited materials, eg. lead, by their reaction with radioactive krypton

    International Nuclear Information System (INIS)

    Tolgyessy, J.; Pruzinec, J.

    1976-01-01

    The invention claims a method of determining substances on a paper carrier based on the substance reaction with 85 Kr gas and the measurement of radioactivity of the kryptonate formed. Lead is shown as an example. Different amounts of lead acetate were deposited on Whatman 2 chromatographic paper as was an unknown sample of Pb salt. The paper was exposed to a 2.5 mCi 85 Kr atmosphere for 48 hours. The activity of the individual spots was then measured, a calibration curve established and the amount of lead in the analyzed sample read-out. (Ha)

  6. Determination of lead in bone tissues by axially viewed inductively coupled plasma multichannel-based emission spectrometry.

    Science.gov (United States)

    Grotti, Marco; Abelmoschi, Maria Luisa; Dalla Riva, Simona; Soggia, Francesco; Frache, Roberto

    2005-04-01

    A new procedure for determining low levels of lead in bone tissues has been developed. After wet acid digestion in a pressurized microwave-heated system, the solution was analyzed by inductively coupled plasma multichannel-based emission spectrometry. Internal standardization using the Co 228.615 nm reference line was chosen as the optimal method to compensate for the matrix effects from the presence of calcium and nitric acid at high concentration levels. The detection limit of the procedure was 0.11 microg Pb g(-1) dry mass. Instrumental precision at the analytical concentration of approximately 10 microg l(-1) ranged from 6.1 to 9.4%. Precision of the sample preparation step was 5.4%. The concentration of lead in SRM 1486 (1.32+/-0.04 microg g(-1)) found using the new procedure was in excellent agreement with the certified level (1.335+/-0.014 microg g(-1)). Finally, the method was applied to determine the lead in various fish bone tissues, and the analytical results were found to be in good agreement with those obtained through differential pulse anodic stripping voltammetry. The method is therefore suitable for the reliable determination of lead at concentration levels of below 1 microg g(-1) in bone samples. Moreover, the multi-element capability of the technique allows us to simultaneously determine other major or trace elements in order to investigate inter-element correlation and to compute enrichment factors, making the proposed procedure particularly useful for investigating lead occurrence and pathways in fish bone tissues in order to find suitable biomarkers for the Antarctic marine environment.

  7. The Chandra Source Catalog: Background Determination and Source Detection

    Science.gov (United States)

    McCollough, Michael; Rots, Arnold; Primini, Francis A.; Evans, Ian N.; Glotfelty, Kenny J.; Hain, Roger; Anderson, Craig S.; Bonaventura, Nina R.; Chen, Judy C.; Davis, John E.; Doe, Stephen M.; Evans, Janet D.; Fabbiano, Giuseppina; Galle, Elizabeth C.; Danny G. Gibbs, II; Grier, John D.; Hall, Diane M.; Harbo, Peter N.; He, Xiang Qun (Helen); Houck, John C.; Karovska, Margarita; Kashyap, Vinay L.; Lauer, Jennifer; McCollough, Michael L.; McDowell, Jonathan C.; Miller, Joseph B.; Mitschang, Arik W.; Morgan, Douglas L.; Mossman, Amy E.; Nichols, Joy S.; Nowak, Michael A.; Plummer, David A.; Refsdal, Brian L.; Siemiginowska, Aneta L.; Sundheim, Beth A.; Tibbetts, Michael S.; van Stone, David W.; Winkelman, Sherry L.; Zografou, Panagoula

    2009-09-01

    The Chandra Source Catalog (CSC) is a major project in which all of the pointed imaging observations taken by the Chandra X-Ray Observatory are used to generate one of the most extensive X-ray source catalog produced to date. Early in the development of the CSC it was recognized that the ability to estimate local background levels in an automated fashion would be critical for essential CSC tasks such as source detection, photometry, sensitivity estimates, and source characterization. We present a discussion of how such background maps are created directly from the Chandra data and how they are used in source detection. The general background for Chandra observations is rather smoothly varying, containing only low spatial frequency components. However, in the case of ACIS data, a high spatial frequency component is added that is due to the readout streaks of the CCD chips. We discuss how these components can be estimated reliably using the Chandra data and what limitations and caveats should be considered in their use. We will discuss the source detection algorithm used for the CSC and the effects of the background images on the detection results. We will also touch on some the Catalog Inclusion and Quality Assurance criteria applied to the source detection results. This work is supported by NASA contract NAS8-03060 (CXC).

  8. The determination of levels of mercury, cadmium and lead in water samples from Naivasha area, Kenya

    International Nuclear Information System (INIS)

    Muigai, P.G.; Kamau, G.N.; Kinyua, A.M.

    1995-01-01

    The analysis of mercury, cadmium and lead in water samples from different environments (Lake Naivasha, River Malewa boreholes and Olkaria geothermal wells) in Naivasha region and their possible origins are reported. The levels of mercury and lead in the water samples were above the maximum permissible limits of 0.005 mg/1 and 0.1 mg/1 respectively, as stipulated by the WHO. On the other hand, 83.3% of the samples had cadmium levels above the maximum permissible limit of 0.01mg/1 in drinking water by WHO. The mercury and lead levels were also higher than those previously obtained from different regions of Kenya, while those for cadmium were within the corresponding range. Possible sources of elevated values were the geology of the surrounding area, sewage treatment works, use of phosphate rock fertilizers and lead fuels.(author)

  9. The impact of using lead pellets on lead contamination of mallards (Anas platyrhynchos in the Czech Republic

    Directory of Open Access Journals (Sweden)

    Zdeňka Hutařová

    2013-01-01

    Full Text Available The aim of the study was to assess the degree of lead contamination in mallards in the Czech Republic as a result of using lead shots for wildfowling. Two sites used for mallard hunting were chosen, namely a flood-control reservoir in Moravia and a small fishpond in Bohemia. Lead concentrations were determined in the tissues of 20 mallards (Anas platyrhynchos raised at those standing open water sites (n = 10 at each site and killed there during the autumn hunting season with a steel shot. Control groups were made up of 20 mallards from the same breeding facility as experimental groups but raised in an enclosure without access to water (n = 10 at each site. Lead concentrations were determined in selected tissues (breast muscle, heart, liver, gizzard, kidney, feathers - quill base, lung, brain and humerus by high resolution continuum source atomic absorption spectrometry. The results showed elevated lead concentrations in all tissues of mallards compared with control in the reservoir in Southern Moravia. The highest lead concentrations (mg/kg were found in the humerus (14.254 ± 4.525 and 5.083 ± 0.748 for experimental and control mallards, respectively. In contrast, lead concentrations in mallards from small fishpond in Southern Bohemia were lower compared to control. Similarly, the highest lead concentrations were found in the humerus (2.219 ± 0.349 and 8.930 ± 1.012 for experimental and control mallards, respectively. This study extends very limited information about lead contamination of wild ducks in the Czech Republic in connection with hunting activities.

  10. Lead isotope ratios in six lake sediment cores from Japan Archipelago: Historical record of trans-boundary pollution sources

    International Nuclear Information System (INIS)

    Hosono, Takahiro; Alvarez, Kelly; Kuwae, Michinobu

    2016-01-01

    Sediment cores from six lakes situated from north to south on the Japanese Archipelago were collected during 2009–2010 to investigate the hypothesis that deposition of lead (Pb) was coming from East Asia (including China, South Korea and eastern part of Russia). Accumulation rates and ages of the lake sediment were estimated by the "2"1"0Pb constant rate of supply model and "1"3"7Cs inputs to reconstruct the historical trends of Pb accumulation. Cores from four lakes located in the north and central Japan, showed clear evidence of Pb pollution with a change in the "2"0"6Pb/"2"0"7Pb and "2"0"8Pb/"2"0"7Pb ratios in the recent sediment as compared to the deeper sediment. Among the six studied lakes, significant inputs of anthropogenic lead emissions were observed at Lake Mikazuki (north Hokkaido in north Japan), Lake Chokai (north of Honshu), and Lake Mikuriga (central part of Honshu). Pb isotopic comparison of collected core sediment and previously reported data for wet precipitation and aerosols from different Asian regions indicate that, before 1900, Pb accumulated in these three lakes was not affected by trans-boundary sources. Lake Mikazuki started to receive Pb emissions from Russia in early 1900s, and during the last two decades, this lake has been affected by trans-boundary Pb pollution from northern China. Lake Chokai has received Pb pollutant from northern China since early 1900s until 2009, whereas for the Lake Mikuriga the major Pb contaminant was transported from southern China during the past 100 years. The results of our study demonstrate that Japan Archipelago has received trans-boundary Pb emissions from different parts of East Asian region depending on location, and the major source region has changed historically. - Highlights: • Historical trend of Pb pollution was recorded in six Japanese Lakes. • Pb concentration and Pb isotope ratios were determined for sediment cores. • High [Pb] and less radiogenic Pb isotope ratios were observed since

  11. Lead isotope ratios in six lake sediment cores from Japan Archipelago: Historical record of trans-boundary pollution sources

    Energy Technology Data Exchange (ETDEWEB)

    Hosono, Takahiro, E-mail: hosono@kumamoto-u.ac.jp [Priority Organization for Innovation and Excellence, Kumamoto University, 2-39-1 Kurokami, Kumamoto 860-8555 (Japan); Alvarez, Kelly [Priority Organization for Innovation and Excellence, Kumamoto University, 2-39-1 Kurokami, Kumamoto 860-8555 (Japan); Kuwae, Michinobu [Senior Research Fellow Center, Ehime University, 2-5 Bunkyo-cho, Matsuyama 790-8577 (Japan)

    2016-07-15

    Sediment cores from six lakes situated from north to south on the Japanese Archipelago were collected during 2009–2010 to investigate the hypothesis that deposition of lead (Pb) was coming from East Asia (including China, South Korea and eastern part of Russia). Accumulation rates and ages of the lake sediment were estimated by the {sup 210}Pb constant rate of supply model and {sup 137}Cs inputs to reconstruct the historical trends of Pb accumulation. Cores from four lakes located in the north and central Japan, showed clear evidence of Pb pollution with a change in the {sup 206}Pb/{sup 207}Pb and {sup 208}Pb/{sup 207}Pb ratios in the recent sediment as compared to the deeper sediment. Among the six studied lakes, significant inputs of anthropogenic lead emissions were observed at Lake Mikazuki (north Hokkaido in north Japan), Lake Chokai (north of Honshu), and Lake Mikuriga (central part of Honshu). Pb isotopic comparison of collected core sediment and previously reported data for wet precipitation and aerosols from different Asian regions indicate that, before 1900, Pb accumulated in these three lakes was not affected by trans-boundary sources. Lake Mikazuki started to receive Pb emissions from Russia in early 1900s, and during the last two decades, this lake has been affected by trans-boundary Pb pollution from northern China. Lake Chokai has received Pb pollutant from northern China since early 1900s until 2009, whereas for the Lake Mikuriga the major Pb contaminant was transported from southern China during the past 100 years. The results of our study demonstrate that Japan Archipelago has received trans-boundary Pb emissions from different parts of East Asian region depending on location, and the major source region has changed historically. - Highlights: • Historical trend of Pb pollution was recorded in six Japanese Lakes. • Pb concentration and Pb isotope ratios were determined for sediment cores. • High [Pb] and less radiogenic Pb isotope ratios

  12. Radioactivity determination of sealed pure beta-sources by surface dose measurements and Monte Carlo simulations

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Chang Heon [Interdisciplinary Program in Radiation Applied Life Science, Seoul National University College of Medicine, Seoul (Korea, Republic of); Jung, Seongmoon [Program in Biomedical Radiation Sciences, Department of Transdisciplinary Studies, Graduate School of Convergence Science and Technology, Seoul National University, Seoul (Korea, Republic of); Choi, Kanghyuk; Son, Kwang-Jae; Lee, Jun Sig [Hanaro Applications Research, Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Ye, Sung-Joon, E-mail: sye@snu.ac.kr [Interdisciplinary Program in Radiation Applied Life Science, Seoul National University College of Medicine, Seoul (Korea, Republic of); Program in Biomedical Radiation Sciences, Department of Transdisciplinary Studies, Graduate School of Convergence Science and Technology, Seoul National University, Seoul (Korea, Republic of); Center for Convergence Research on Robotics, Advance Institutes of Convergence Technology, Seoul National University, Suwon (Korea, Republic of)

    2016-04-21

    This study aims to determine the activity of a sealed pure beta-source by measuring the surface dose rate using an extrapolation chamber. A conversion factor (cGy s{sup −1} Bq{sup −1}), which was defined as the ratio of surface dose rate to activity, can be calculated by Monte Carlo simulations of the extrapolation chamber measurement. To validate this hypothesis the certified activities of two standard pure beta-sources of Sr/Y-90 and Si/P-32 were compared with those determined by this method. In addition, a sealed test source of Sr/Y-90 was manufactured by the HANARO reactor group of KAERI (Korea Atomic Energy Research Institute) and used to further validate this method. The measured surface dose rates of the Sr/Y-90 and Si/P-32 standard sources were 4.615×10{sup −5} cGy s{sup −1} and 2.259×10{sup −5} cGy s{sup −1}, respectively. The calculated conversion factors of the two sources were 1.213×10{sup −8} cGy s{sup −1} Bq{sup −1} and 1.071×10{sup −8} cGy s{sup −1} Bq{sup −1}, respectively. Therefore, the activity of the standard Sr/Y-90 source was determined to be 3.995 kBq, which was 2.0% less than the certified value (4.077 kBq). For Si/P-32 the determined activity was 2.102 kBq, which was 6.6% larger than the certified activity (1.971 kBq). The activity of the Sr/Y-90 test source was determined to be 4.166 kBq, while the apparent activity reported by KAERI was 5.803 kBq. This large difference might be due to evaporation and diffusion of the source liquid during preparation and uncertainty in the amount of weighed aliquot of source liquid. The overall uncertainty involved in this method was determined to be 7.3%. We demonstrated that the activity of a sealed pure beta-source could be conveniently determined by complementary combination of measuring the surface dose rate and Monte Carlo simulations.

  13. Ion exchange separation of lead from strontium in certified reference samples and spectrophotometric determination of lead as extractable ion-pair of eosin2- and the lead-cryptand (2.2.2)2+ complex

    International Nuclear Information System (INIS)

    Al-Merey, R.; Al-Shayah, O.

    2004-01-01

    A two-step procedure including anion exchange separation of lead from strontium in geological reference samples and a spectrophotometric determination of the separated lead as lead-cryptate (2.2.2) complex is presented. The exchangeable anion Cl - of the ion exchange resin (Dowex 1x4) is changed to Br - in 6M HBr solution. Lead is quantitatively retained in the column from 0.5M HBr medium, while Sr 2+ , Ba 2+ , Ca 2+ , Mg 2+ , Na + , K + , Fe 3+ , Cr 3+ , and Al 3+ are passed through. Subsequently the retained Ph is eluted from the column with 6M HBr. The separation efficiency of the resin is controlled using mixed standard solution of (Pb, Sr, Ca, Mg, Ba, Na, K, Fe, Cr and Al), and radioactive tracer of 85 Sr and 131 Ba. The resin selectivity coefficient (K) of separating Pb from Sr is found to be K S r P b∼10 9 . The Spectrophotometric method of lead determination is based on the formation of lead-crytate (2.2.2) complex at pH 8.3 using borate/HCl as a buffer solution. Then the ion-pair of eosin 2+ and lead-cryptand (2.2.2) complex is extracted with chloroform, finally the absorbance of the extractable legend is measured at 550 nm. The extraction recovery, accuracy, precision, linearity and detection limit of the spectrophotometric method are 99.58%, 1.7%, 0.080μg mL -1 , o-9μg mL -1 , and 0.060μg mL -1 , respectively. (author)

  14. Lead isotopes and lead shot ingestion in the globally threatened marbled teal (Marmaronetta angustirostris) and white-headed duck (Oxyura leucocephala)

    International Nuclear Information System (INIS)

    Svanberg, Fredrik; Mateo, Rafael; Hillstroem, Lars; Green, Andy J.; Taggart, Mark A.; Raab, Andrea; Meharg, Andy A.

    2006-01-01

    Lead isotope ratios ( 206 Pb/ 207 Pb and 208 Pb/ 207 Pb) and concentrations in the livers and bones of marbled teal and white-headed duck found dead or moribund were determined in order to establish the main lead source in these waterfowl species. Lead concentrations in bone (dry weight) and liver (wet weight) were found to be very high in many of the white-headed ducks (bone: geometric mean = 88.9 ppm, maximum = 419 ppm; liver: geometric mean = 16.8 ppm, maximum = 57.0 ppm). Some of the marbled teal had high lead levels in the bones but liver lead levels were all low (bone: geometric mean = 6.13 ppm, maximum = 112 ppm; liver: geometric mean = 0.581 ppm, maximum = 4.77 ppm). Ingested lead shot were found in 71% of the white-headed duck and 20% of the marbled teal. The 206 Pb/ 207 Pb ratio in livers and bones of white-headed ducks and marbled teals showed no significant differences compared to the ratios obtained from lead shot. The 206 Pb/ 207 Pb ratio in bones of marbled teal ducklings with the highest lead concentrations tended to resemble the ratios of lead shot, which supports our hypothesis that the lead was derived from the hens. We also found that the lead ratios of lead shot and lead ratios described for soils in the area overlapped, but also that the isotopic ratio 206 Pb/ 207 Pb in lead shot used in Spain has a narrow range compared with those used in North America. The principal source of lead in many of these birds was, however, most likely lead shot, as supported by the similar isotopic ratios, high lead concentrations in tissues and evidence of ingested shot

  15. Lead isotopes and lead shot ingestion in the globally threatened marbled teal (Marmaronetta angustirostris) and white-headed duck (Oxyura leucocephala)

    Energy Technology Data Exchange (ETDEWEB)

    Svanberg, Fredrik [Department of Environmental Toxicology, Evolutionary Biology Centre, Uppsala University, Norbyvaegen 18A, SE-752 36 Uppsala (Sweden)]. E-mail: fredriksvanberg@hotmail.com; Mateo, Rafael [Instituto de Investigacion en Recursos Cinegeticos, IREC (CSIC-UCLM-JCCM), Ronda de Toledo s/n, 13071 Ciudad Real (Spain); Hillstroem, Lars [Institute of Maths, Natural and Computer Science, University of Gaevle, SE-801 76 Gaevle (Sweden); Green, Andy J. [Wetland Ecology Group, Estacion Biologica de Donana-CSIC, Pabellon del Peru, Avenida Maria Luisa s/n, E-40013 Seville (Spain); Taggart, Mark A. [School of Biological Sciences, University of Aberdeen, Cruickshank Bld, St Machar Dr, Aberdeen, Scotland, AB24 3UU (United Kingdom); Raab, Andrea [School of Biological Sciences, University of Aberdeen, Cruickshank Bld, St Machar Dr, Aberdeen, Scotland, AB24 3UU (United Kingdom); Meharg, Andy A. [School of Biological Sciences, University of Aberdeen, Cruickshank Bld, St Machar Dr, Aberdeen, Scotland, AB24 3UU (United Kingdom)

    2006-11-01

    Lead isotope ratios ({sup 206}Pb/{sup 207}Pb and {sup 208}Pb/{sup 207}Pb) and concentrations in the livers and bones of marbled teal and white-headed duck found dead or moribund were determined in order to establish the main lead source in these waterfowl species. Lead concentrations in bone (dry weight) and liver (wet weight) were found to be very high in many of the white-headed ducks (bone: geometric mean = 88.9 ppm, maximum = 419 ppm; liver: geometric mean = 16.8 ppm, maximum = 57.0 ppm). Some of the marbled teal had high lead levels in the bones but liver lead levels were all low (bone: geometric mean = 6.13 ppm, maximum = 112 ppm; liver: geometric mean = 0.581 ppm, maximum = 4.77 ppm). Ingested lead shot were found in 71% of the white-headed duck and 20% of the marbled teal. The {sup 206}Pb/{sup 207}Pb ratio in livers and bones of white-headed ducks and marbled teals showed no significant differences compared to the ratios obtained from lead shot. The {sup 206}Pb/{sup 207}Pb ratio in bones of marbled teal ducklings with the highest lead concentrations tended to resemble the ratios of lead shot, which supports our hypothesis that the lead was derived from the hens. We also found that the lead ratios of lead shot and lead ratios described for soils in the area overlapped, but also that the isotopic ratio {sup 206}Pb/{sup 207}Pb in lead shot used in Spain has a narrow range compared with those used in North America. The principal source of lead in many of these birds was, however, most likely lead shot, as supported by the similar isotopic ratios, high lead concentrations in tissues and evidence of ingested shot.

  16. Optical Determination of Lead Chrome Green in Green Tea by Fourier Transform Infrared (FT-IR Transmission Spectroscopy.

    Directory of Open Access Journals (Sweden)

    Xiaoli Li

    Full Text Available The potential of Fourier transform infrared (FT-IR transmission spectroscopy for determination of lead chrome green in green tea was investigated based on chemometric methods. Firstly, the qualitative analysis of lead chrome green in tea was performed based on partial least squares discriminant analysis (PLS-DA, and the correct rate of classification was 100%. And then, a hybrid method of interval partial least squares (iPLS regression and successive projections algorithm (SPA was proposed to select characteristic wavenumbers for the quantitative analysis of lead chrome green in green tea, and 19 wavenumbers were obtained finally. Among these wavenumbers, 1384 (C = C, 1456, 1438, 1419(C = N, and 1506 (CNH cm-1 were the characteristic wavenumbers of lead chrome green. Then, these 19 wavenumbers were used to build determination models. The best model was achieved by least squares support vector machine (LS-SVMalgorithm with high coefficient of determination and low root-mean square error of prediction set (R2p = 0.864 and RMSEP = 0.291. All these results indicated the feasibility of IR spectra for detecting lead chrome green in green tea.

  17. X-ray radiometric analysis of lead and zinc concentrates using germanium radiation detector

    International Nuclear Information System (INIS)

    Vajgachev, A.A.; Mamysh, V.A.; Mil'chakov, V.I.; Shchekin, K.I.; Berezkin, V.V.

    1975-01-01

    The results of determination of lead, zinc and iron in lead and zinc concentrates by the X-ray-radiometric method with the use of germanium semiconductor detector are presented. In the experiments the 57 Co source and tritium-zirconium target were used. The activity of 57 Co was 2 mc. The area of the germanium detector employed was 5g mm 2 , its thickness - 2.3 mm. In lead concentrates zinc and iron were determined from the direct intensity of K-series radiation. In the analysis of zinc concentrates the same conditions of recording and excitation were used as in the case of lead concentrates, but the measurements were conducted in saturated layers. It is demonstrated that the use of germanium semiconductor detectors in combination with the suggested methods of measurements makes it possible to perform determination of iron, zinc and lead in zinc and lead concentrates with permissible error

  18. Alpha spectrometry of thick sources. I. Application to alpha emitters determination

    International Nuclear Information System (INIS)

    Acena, M.L.; Garcia-Torano, E.; Rivero, M.C.

    1977-01-01

    A method for determining alpha emitters by silicon surface barrier detector spectroscopy using thick sources is studied. Two types of spectra have been obtained. They have different shapes of line according to the procedure used for preparing the sources. For both spectra a computing least square programme has been developed. In this way it is possible to calculate line intensities with accuracy better than 20 percent. (author) [es

  19. Deaths related to lead poisoning in the United States, 1979-1998

    International Nuclear Information System (INIS)

    Kaufmann, R.B.; Staes, Catherine J.; Matte, Thomas D.

    2003-01-01

    This study was conducted to describe trends in US lead poisoning-relate deaths between 1979 and 1998. The predictive value of relevant ICD-9 codes was also evaluated. Multiple cause-of-death files were searched for record containing relevant ICD-9 codes, and underlying causes and demographic characteristics were assessed. For 1979-1988, death certificates were reviewed; lead source information was abstracted and accuracy of coding was determined. An estimated 200 lead poisoning-related deaths occurred from 1979 to 1998. Most were among males (74%), Blacks (67%), adults of age ≥45 years (76%), and Southerners (70%). The death rate was significantly lower in more recent years. An alcohol-related code was a contributing cause for 28% of adults. Only three of nine ICD-9 codes for lead poisoning were highl predictive of lead poisoning-related deaths. In conclusion, lead poisoning-related death rates have dropped dramatically since earlier decades and are continuing to decline. However, the findings imply that moonshine ingestion remains a source of high-dose lead exposure in adults

  20. Application of laser ablation inductively coupled plasma multicollector mass spectometry in determination of lead isotope ratios in common glass for forensic purposes

    International Nuclear Information System (INIS)

    Sjåstad, Knut-Endre; Andersen, Tom; Simonsen, Siri Lene

    2013-01-01

    Samples of glass used as trace evidence in criminal cases are commonly small, with particle sizes below a millimeter. To perform chemical analysis suitable for forensic purposes, methods capable of analyzing such small samples are required. In this paper, analyses of lead isotope ratios by means of laser ablation inductively coupled multicollector mass spectrometry (LA-MC-ICP-MS) are presented. Sampling by use of laser ablation allows fragments down to 0.1 mg to be analyzed with sufficient precision to discriminate between glasses of different origin. In fact, the use of lead isotopes determined by LA-MC-ICP-MS approaches the discrimination attainable by multicollector inductively coupled plasma mass spectrometry (MC-ICP-MS) analysis of dissolved samples of 5 mg or more. Further, we have obtained a probability distribution by two dimensional kernel density estimates for the collected data set as an alternative presentation method to the well-established bivariate plot. The underlying information available from kernel density estimates is of importance for forensic scientists involved in probabilistic interpretation of physical evidence. - Highlights: • Lead isotope ratios prove suitable to discriminate glass for forensic purposes. • 96% of glass samples from different sources were separated by lead isotopic ratios. • Laser ablation allows fragments of glass with extension of 0.5 mm to be analyzed. • Isotopic ratios of lead are well suited for statistical analysis of evidence

  1. Neurological aspects of lead intoxication

    Energy Technology Data Exchange (ETDEWEB)

    Lehner, H

    1980-05-08

    This study gives a survey over the medical and scientific literature on lead intoxications, which were published until 1979. Neurologic aspects are of particular interest. At present dramatic cases of lead intoxications occur only rarely. However, there are numerous studies about cases of chronical, partly subclinical intoxications. This chronical type of lead intoxication can become manifest clinically as relatively vague symptoms, for example vertigos, insomnia, headaches and weakness. Contrary to this, serious encephalopathies, even with fatal outcome, and polyneuropathies with typical paresis of the radial nerve are preferably observed in acute lead intoxications. Besides the numerous sources of intoxication, also the different opinions found in literature are discussed, concerning the effects of lead on the human body. The fact that there are differing opinions about the limiting value of the blood-lead level at which intoxication symptoms have to be expected, becomes apparent when the determined blood-lead level values are compared and evaluated. Besides the description of general intoxication effects, the discussion of the neurologic aspects found in literature - not only those concerning the central, but also the peripheral system - are preferably concerned. Reports about neuropsychical alterations due to lead exposure, which are mainly found in children, supplement the numerous descriptions of the macroscopic and microscopic alterations of the nervous system provoked by lead. Finally the therapeutic and prophylactic measures given in the literature are discussed.

  2. Preferred orientation determination using line source x-ray diffraction

    International Nuclear Information System (INIS)

    Kimmel, G.; Shmarjahu, D.

    1977-10-01

    A texture goniometer has been attached to a diffractometer connected to a line-focus x-ray source. Reasonable results are obtained for the texture of rolled sheets and the test procedure is given. To illustrate the test procedure, the determination of preferred orientation in cold-rolled copper is described, as compared with random powder of sintered copper. Improvements of the measurements are proposed

  3. Determination of lead in clay enameled by X-ray fluorescence technique in Total reflection and by Scanning Electron Microscopy

    International Nuclear Information System (INIS)

    Zarazua O, G.; Carapia M, L.

    2000-01-01

    This work has the objective of determining lead free in the glazed commercial stewing pans using the X-ray fluorescence technique in Total reflection (FRX) and the observation and semiquantitative determination of lead by Analytical Scanning Electron Microscopy (ASEM). (Author)

  4. Determination of Cadmium, Lead and Zinc in Vegetables in Jaipur (India).

    Science.gov (United States)

    Kumar, Ashok; Verma, P S

    2014-01-01

    An atomic absorption spectroscopic method was used for the determination of Lead, Cadmium and Zinc in vegetables grown in and around Jaipur food stuffs irrigated with industrial waste water. Vegetable samples were collected after maturity, and analyzed, such as spinach (Spinacia oleracea), ladyfinger (Abelmoschus esulentus), pepper mint (Menthe pipereta), brinjal (Solanum melongena), coriander (Coriandrum sativum), cauliflower (Brassica oleracea), onion (Allium cepa), radish (Raphanus sativus), pointedgourd (Trichosanthes dioica), bottlegourd (Lagenaria siceraria), chilies (Capsicum annum), ribbedgourd (Luffa acutangula) and pumpkin (Curcurbites pepo). The concentration of Lead ranged between 1.40-71.06 ppm, Cadmium 0.61-34.48 ppm and Zinc 0.39-187.26 ppm in vegetable samples. The results reveal that urban consumers are at greater risk of purchasing fresh vegetables with high levels of heavy metal, beyond the permissible limits, as defined by the Indian Prevention of Food Adulteration Act, 1954 and WHO.

  5. Archives of Atmospheric Lead Pollution

    Science.gov (United States)

    Weiss, Dominik; Shotyk, William; Kempf, Oliver

    Environmental archives such as peat bogs, sediments, corals, trees, polar ice, plant material from herbarium collections, and human tissue material have greatly helped to assess both ancient and recent atmospheric lead deposition and its sources on a regional and global scale. In Europe detectable atmospheric lead pollution began as early as 6000years ago due to enhanced soil dust and agricultural activities, as studies of peat bogs reveal. Increased lead emissions during ancient Greek and Roman times have been recorded and identified in many long-term archives such as lake sediments in Sweden, ice cores in Greenland, and peat bogs in Spain, Switzerland, the United Kingdom, and the Netherlands. For the period since the Industrial Revolution, other archives such as corals, trees, and herbarium collections provide similar chronologies of atmospheric lead pollution, with periods of enhanced lead deposition occurring at the turn of the century and since 1950. The main sources have been industry, including coal burning, ferrous and nonferrous smelting, and open waste incineration until c.1950 and leaded gasoline use since 1950. The greatest lead emissions to the atmosphere all over Europe occurred between 1950 and 1980 due to traffic exhaust. A marked drop in atmospheric lead fluxes found in most archives since the 1980s has been attributed to the phasing out of leaded gasoline. The isotope ratios of lead in the various archives show qualitatively similar temporal changes, for example, the immediate response to the introduction and phasing out of leaded gasoline. Isotope studies largely confirm source assessments based on lead emission inventories and allow the contributions of various anthropogenic sources to be calculated.

  6. Vaporization of mercury from molten lead droplets doped with mercury: Pb/Hg source term experiment for the APT/SILC target

    International Nuclear Information System (INIS)

    Tutu, N.K.; Greene, G.A.

    1994-09-01

    Experiments were performed to measure the fraction of mercury inventory released when droplets of molten lead, doped with a known concentration of mercury, fall through a controlled environment. The temperature of molten droplets ranged from 335 C to 346 C, and the concentration of mercury in the droplets ranged from 0.2 mass % to 1.0 mass %. The environment consisted of an air stream, at a temperature nominally equal to the melt temperature, and moving vertically upwards at a velocity of 10 cm/s. Direct observations and chemical analysis showed that no mercury was released from the molten droplets. Based upon the experimental results, it is concluded that no mercury vapor is likely to be released from the potentially molten source rod material in the APT-SILC Neutron Source Array to the confinement atmosphere during a postulated Large Break Loss Of Coolant Accident scenario leading to the melting of a fraction of the source rods

  7. Determination of void fraction from source range monitor and mass flow rate data

    International Nuclear Information System (INIS)

    McCormick, R.D.

    1986-09-01

    This is a report on the calculation of the TMI-2 primary coolant system local void fraction from source range neutron flux monitor data and from hot leg mass flowrate meter data during the first 100 minutes of the accident. The methods of calculation of void fraction from the two data sources is explained and the results are compared. It is indicated that the void fraction determined using the mass flowrate data contained an error of unknown magnitude due to the assumption of constant homogeneous volumetric flowrate used in the calculation and required further work. Void fraction determined from the source range monitor data is felt to be usable although an uncertainty analysis has not been performed

  8. Photon spectrometry for the determination of the dose-rate constant of low-energy photon-emitting brachytherapy sources

    International Nuclear Information System (INIS)

    Chen, Zhe Jay; Nath, Ravinder

    2007-01-01

    Accurate determination of dose-rate constant (Λ) for interstitial brachytherapy sources emitting low-energy photons (<50 keV) has remained a challenge in radiation dosimetry because of the lack of a suitable absolute dosimeter for accurate measurement of the dose rates near these sources. Indeed, a consensus value of Λ taken as the arithmetic mean of the dose-rate constants determined by different research groups and dosimetry techniques has to be used at present for each source model in order to minimize the uncertainties associated with individual determinations of Λ. Because the dosimetric properties of a source are fundamentally determined by the characteristics of the photons emitted by the source, a new technique based on photon spectrometry was developed in this work for the determination of dose-rate constant. The photon spectrometry technique utilized a high-resolution gamma-ray spectrometer to measure source-specific photon characteristics emitted by the low-energy sources and determine their dose-rate constants based on the measured photon-energy spectra and known dose-deposition properties of mono-energetic photons in water. This technique eliminates many of the difficulties arising from detector size, the energy dependence of detector sensitivity, and the use of non-water-equivalent solid phantoms in absolute dose rate measurements. It also circumvents the uncertainties that might be associated with the source modeling in Monte Carlo simulation techniques. It was shown that the estimated overall uncertainty of the photon spectrometry technique was less than 4%, which is significantly smaller than the reported 8-10% uncertainty associated with the current thermo-luminescent dosimetry technique. In addition, the photon spectrometry technique was found to be stable and quick in Λ determination after initial setup and calibration. A dose-rate constant can be determined in less than two hours for each source. These features make it ideal to determine

  9. Determination of source term for Krsko NPP extended fuel cycle

    International Nuclear Information System (INIS)

    Nemec, T.; Persic, A.; Zagar, T.; Zefran, B.

    2004-01-01

    The activity and composition of the potential radioactive releases (source term) is important in the decision making about off-site emergency measures in case of a release into environment. Power uprate of Krsko NPP during modernization in 2000 as well as changing of the fuel type and the core design have influenced the source term value. In 2003 a project of 'Jozef Stefan' Institute and Slovenian nuclear safety administration determined a plantspecific source term for new conditions of fuel type and burnup for extended fuel cycle. Calculations of activity and isotopic composition of the core have been performed with ORIGEN-ARP program. Results showed that the core activity for extended 15 months fuel cycle is slightly lower than for the 12 months cycles, mainly due to larger share of fresh fuel. (author)

  10. Lead and other elements in house dust of Japanese residences – Source of lead and health risks due to metal exposure

    International Nuclear Information System (INIS)

    Yoshinaga, Jun; Yamasaki, Kumiko; Yonemura, Ayumi; Ishibashi, Yuri; Kaido, Takaya; Mizuno, Kodai; Takagi, Mai; Tanaka, Atsushi

    2014-01-01

    The levels of 25 elements in house dust collected from 100 general Japanese residences were measured. Factor analysis was applied on the multi-element data to explore source of Pb (median concentration 49.1 mg/kg) in house dust. Six factors were extracted and Pb was found to have great loading on the fifth factor with Sb and Sn, suggesting solder (Sn), and plastic and metals (Sb) may be the sources of Pb in the house dust of Japanese residences. No significant loading was found on soil-related factors indicating non-significant contribution of Pb in track-in soil. Seven heavy metals (Cd, Cu, Mo, Pb, Sb, Sn, and Zn) were found in house dust at >10 times more condensed than crustal abundance. Health risk of these elements to children via the ingestion of house dust was estimated based on the comparison with tolerable daily intake and found to be non-significant for most of the elements. - Highlights: • Multi-element analysis was carried out for house dust from households in Japan. • Factor analysis was applied on the multivariate data set. • The abundance of lead had a close relationship with antimony and tin in house dust. • Health risk of heavy metals in house dust for children was not serious. - Major source of Pb in house dust of Japanese residences was not track-in soil but unknown materials that contain Pb and Sb and/or Sn

  11. STATCONT: A statistical continuum level determination method for line-rich sources

    Science.gov (United States)

    Sánchez-Monge, Á.; Schilke, P.; Ginsburg, A.; Cesaroni, R.; Schmiedeke, A.

    2018-01-01

    STATCONT is a python-based tool designed to determine the continuum emission level in spectral data, in particular for sources with a line-rich spectrum. The tool inspects the intensity distribution of a given spectrum and automatically determines the continuum level by using different statistical approaches. The different methods included in STATCONT are tested against synthetic data. We conclude that the sigma-clipping algorithm provides the most accurate continuum level determination, together with information on the uncertainty in its determination. This uncertainty can be used to correct the final continuum emission level, resulting in the here called `corrected sigma-clipping method' or c-SCM. The c-SCM has been tested against more than 750 different synthetic spectra reproducing typical conditions found towards astronomical sources. The continuum level is determined with a discrepancy of less than 1% in 50% of the cases, and less than 5% in 90% of the cases, provided at least 10% of the channels are line free. The main products of STATCONT are the continuum emission level, together with a conservative value of its uncertainty, and datacubes containing only spectral line emission, i.e., continuum-subtracted datacubes. STATCONT also includes the option to estimate the spectral index, when different files covering different frequency ranges are provided.

  12. Uranium-lead age determinations on granitic rocks from the eastern Bushveld Complex

    International Nuclear Information System (INIS)

    Faurie, J.N.

    1978-08-01

    Uranium-lead age determinations were carried out on four types of granitic rocks from the eastern Bushveld Complex. The oldest rocks in the area are gneisses and felsites - 2604 plus minus 100 m.y. old - which form the centre of the Dennilton dome. The Rooiberg felsites could not be dated directly because of the absence of zircon, however a porphyritic granite sill, which shows intrusive relations with the Rooiberg felsites, was dated at 2090 plus minus 40 m.y., an age which can also be regarded as a minimum age for the Rooiberg felsites. No reliable age could be determined for the granophyres because of the large amount of lead-loss reflected in the zircon. The majority of zircons from these granophyres showed a peculiar hieroglyphic texture, a phenomena which has not yet been recorded in literature. The samples collected from the granites gave an age of 1950 plus minus 80 m.y. and thus form part of the Nebo Granite. Attempts have been made to obtain more concordant zircon ages throughout the present study. Although some success was achieved by analysing different size fractions of a zircon population, the non-magnetic fractions gave the most promising results [af

  13. Lead Isotope Characterization of Petroleum Fuels in Taipei, Taiwan

    Directory of Open Access Journals (Sweden)

    Pei-Hsuan Yao

    2015-04-01

    Full Text Available Leaded gasoline in Taiwan was gradually phased out from 1983 to 2000. However, it is unclear whether unleaded gasoline still contributes to atmospheric lead (Pb exposure in urban areas. In this study, Pb isotopic compositions of unleaded gasolines, with octane numbers of 92, 95, 98, and diesel from two local suppliers in Taipei were determined by multi-collector inductively coupled plasma mass spectrometry with a two-sigma uncertainty of ± 0.02 %. Lead isotopic ratios of vehicle exhaust (208Pb/207Pb: 2.427, 206Pb/207Pb: 1.148, as estimated from petroleum fuels overlap with the reported aerosol data. This agreement indicates that local unleaded petroleum fuels, containing 10–45 ng·Pb·g−1, are merely one contributor among various sources to urban aerosol Pb. Additionally, the distinction between the products of the two companies is statistically significant in their individual 208Pb/206Pb ratios (p-value < 0.001, t test. Lead isotopic characterization appears to be applicable as a “fingerprinting” tool for tracing the sources of Pb pollution.

  14. EPA Leads the Way on Lead Exposure Science and Risk Management

    Science.gov (United States)

    EPA researchers have developed a modeling approach that improves our understanding of the relationship between lead concentrations of various sources (drinking water, soil and dust, food, and air) and children’s blood-lead levels.

  15. Record of Anthropocene pollution sources of lead in disturbed peatlands from Southern Poland

    Science.gov (United States)

    Fiałkiewicz-Kozieł, Barbara; De Vleeschouwer, François; Mattielli, Nadine; Fagel, Nathalie; Palowski, Bernard; Pazdur, Anna; Smieja-Król, Beata

    2018-04-01

    The importance of human impacts on Earth has led to the proposal of a new geologic epoch called the Anthropocene. However markers, recognizable in all records, are required to define this period. Here we combine elemental geochemistry with stable lead (Pb) isotopes and mineralogical analyses to decipher the sources of lead in two exploited ombrotrophic peat bogs (Puścizna Mała and Puścizna Krauszowska) from Southern Poland. The most disturbed parts of the cores, distinguished using bulk density and age-depth models (22-45 cm in PM and 22-46 cm in PK), were excluded from the interpretation. The two studied cores record ca. 2000 years of variations in lead accumulation rates and isotopic compositions. In the lowest part of the cores (2nd to 4th century AD for Puścizna Mała and 2nd century BC to 2nd century AD for Puścizna Krauszowska), the 206Pb/207Pb ratios (1.188) are consistent with natural supplies from the erosion of the nearby Tatra Mountains. From the 9th to the 19th century AD, 206Pb/207Pb ratios (1.176-1.179) are similar to the signatures obtained from Polish galena ores. The highest Pb accumulation rates are found around 1950 AD and reflect the primary influence of bituminous coal combustion together with the secondary influence of leaded gasoline. This result agrees with the occurrence and abundance of spheroidal aluminosilicates, an unambiguous marker of human industrial activity and coal burning as well as with the acceleration of Zn, Cd and Fe accumulation rate. Our results provide evidence that similar geochemical patterns exist in both analysed cores despite differences in the history of peatland exploitation. Therefore, given that extra care is taken to identify the disturbed peat layers, exploited peatlands can be used to record past changes in lead isotopic signature during the Anthropocene.

  16. Semi-empirical Determination of Detection Efficiency for Voluminous Source by Effective Solid Angle Method

    Energy Technology Data Exchange (ETDEWEB)

    Kang, M. Y.; Kim, J. H.; Choi, H. D. [Seoul National Univ., Seoul (Korea, Republic of); Sun, G. M. [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2014-05-15

    In the field of γ-ray measurements, the determination of full energy (FE) absorption peak efficiency for a voluminous sample is difficult, because the preparation of the certified radiation source with the same chemical composition and geometry for the original voluminous sample is not easy. In order to solve this inconvenience, simulation or semi-empirical methods are preferred in many cases. Effective Solid Angle (ESA) Code which includes semi-empirical approach has been developed by the Applied Nuclear Physics Group in Seoul National University. In this study, we validated ESA code by using Marinelli type voluminous KRISS (Korea Research Institute of Standards and Science) CRM (Certified Reference Materials) sources and IAEA standard γ-ray point sources. And semi-empirically determined efficiency curve for voluminous source by using the ESA code is compared with the experimental value. We calculated the efficiency curve of voluminous source from the measured efficiency of standard point source by using the ESA code. We will carry out the ESA code validation by measurement of various CRM volume sources with detector of different efficiency.

  17. Nomogram for Determining Shield Thickness for Point and Line Sources of Gamma Rays

    Energy Technology Data Exchange (ETDEWEB)

    Joenemalm, C; Malen, K

    1966-10-15

    A set of nomograms is given for the determination of the required shield thickness against gamma radiation. The sources handled are point and infinite line sources with shields of Pb, Fe, magnetite concrete (p = 3.6), ordinary concrete (p = 2.3) or water. The gamma energy range covered is 0.5 - 10 MeV. The nomograms are directly applicable for source and dose points on the surfaces of the shield. They can easily be extended to source and dose points in other positions by applying a geometrical correction. Also included are data for calculation of the source strength for the most common materials and for fission product sources.

  18. Nomogram for Determining Shield Thickness for Point and Line Sources of Gamma Rays

    International Nuclear Information System (INIS)

    Joenemalm, C.; Malen, K

    1966-10-01

    A set of nomograms is given for the determination of the required shield thickness against gamma radiation. The sources handled are point and infinite line sources with shields of Pb, Fe, magnetite concrete (p = 3.6), ordinary concrete (p = 2.3) or water. The gamma energy range covered is 0.5 - 10 MeV. The nomograms are directly applicable for source and dose points on the surfaces of the shield. They can easily be extended to source and dose points in other positions by applying a geometrical correction. Also included are data for calculation of the source strength for the most common materials and for fission product sources

  19. Pollutant Source Tracking (PST) Technical Guidance

    Science.gov (United States)

    2011-12-01

    in the context of heavy metals (lead, copper), is considered to be a minor process contribution to the source fingerprint. 3.7 RAPID SCREENING...limits (summarized in Table 2) support the use of ICP-AES (ICP-OES) for heavy metal determination in soils , sediments, wastewater and other matrices...are included here. Isotopic ratios of stable isotopes of the metal of interest can be used for source identification and apportionment in complex

  20. Remediation of lead contaminated soil

    International Nuclear Information System (INIS)

    Urban, W.; Krishnamurthy, S.

    1992-01-01

    Lead contaminated soil in urban area is of major concern because of the potential health risk to children. Many studies have established a direct correlation between lead in soil and elevated blood lead levels in children. In Minneapolis, Minnesota, Mielke et al. (1983) reported that 50% of the Hmong children with lead poisioning were in areas where soil lead levels were between 500 and 1000 micrograms per gram (ug/g), and 40% of the children suffering from lead poisioning lived in areas where soil lead levels exceeded 1000 ug/g. In urban areas, lead pollution in soil has come from many different sources. The sources include lead paint, lead batteries and automobile exhaust. Olson and Skogerbee (1975) found the following lead compounds in soils where the primary source of pollution was from automobiles: lead sulfate, lead oxide, lead dioxide, lead sulfide, and metallic lead. The primary form of lead found was lead sulfate. Lead sulfate, lead tetraoxide, white lead, and other forms of lead have been used in the manufacture of paints for houses. At present, two remediation techniques, solidification and Bureau of Mines fluosilicic acid leaching, are available for lead-contaminated sites. The objective of the present investigation at the Risk Reduction Engineering Laboratory (RREL), Edison, was to try to solubilize the lead species by appropriate reagents and then recover the contaminants by precipitation as lead sulfate, using environmentally acceptable methods. The apparatus used for mixing was a LabMaster mixer, with variable speed and high-shear impeller. Previous work had used nitric acid for dissolving metallic lead. Owing to the environmental concerns, it was decided to use acetic acid in the presence of oxygen. The theoretical justification for this approach is the favorable redox potential for the reaction between metallic lead, acetic acid, and gaseous oxygen

  1. Magnitudes and sources of precipitation and dry deposition fluxes of industrial and natural leads to the North Pacific at Enewetak

    International Nuclear Information System (INIS)

    Settle, D.M.; Patterson, C.C.

    1982-01-01

    A total atmospheric PB input flux of 7 ng Pb cm - 2 yr - 1 was measured in the North Pacific Easterlies at Enewetak. Parameters used to measure this flux were ratio of dry deposition flux to precipitation flux; Pb/ 210 Pb in precipitation and seawater; 210 Pb flux; washout factor; and Pb concentrations in air, rain, and dry deposition deposits. Relations among these parameters estabilished at Enewetak were used to recompute and comfirm previous estimates of lead fluxes to the oceans (ng Pb cm - 2 yr - 1 ) at the following locations: North Altantic Westerlies, 170; North Pacific Westerlies, 50; and South Pacific Easterlies, 3. Prehistoric lead output fluxes to sediments (ng Pb cm - 2 yr - 1 ) at these locations have been previously measured and were 4 (Enewetak); 30 North Atlantic Westerlies; 3 North Pacific Westerlies; 4 South Pacific Easterlies. These data show that the rates of atmospheric imputs of lead to the oceans vary directly with variations in rates of upwind emission of industrial lead from urban complexes on land. In the North Pacific and North Atlantic, present rates of atmospheric lead inputs are 10-fold greater than prehistoric outputs. In equatorial regions, present inputs and past outputs are more nearly equal. These observations disclose the effects of intense industrial atmospheric emissions of lead in the northern hemisphere westerlies which have overwhelmed prehistoric natural fluxes of lead to the oceans. The average concentration of lead in marine air at Enewetak is 170n pg m - 3 and varies less than a factor of 2 from that mean. One to 15% of this lead comes from seaspray, while the remainder comes from sources on land. About 90% of the seaspray lead is industrial, while 80 to 99% of that originating from land sources is industrial. Concentrations of lead in rain at Enewetak range from 6 to 63 pg/g with a mean value of 28

  2. Determination of strontium and lead isotope ratios of grains using high resolution inductively coupled plasma mass spectrometer with single collector

    International Nuclear Information System (INIS)

    Shinozaki, Miyuki; Ariyama, Kaoru; Kawasaki, Akira; Hirata, Takafumi

    2010-01-01

    A method for determining strontium and lead isotope ratios of grains was developed. The samples investigated in this study were rice, barley and wheat. The samples were digested with nitric acid and hydrogen peroxide, and heated in a heating block. Strontium and lead were separated from the matrix by adding an acid digested solution into a column packed with Sr resin, which has selectivity for the absorption of strontium and lead. Strontium and lead isotope ratios were determined using a high-resolution inductively coupled plasma mass spectrometer (HR-ICP-MS) with a single collector. The intraday relative standard deviations of 87 Sr/ 86 Sr and lead isotope ratios ( 204 Pb/ 206 Pb, 207 Pb/ 206 Pb, 208 Pb/ 206 Pb) by HR-ICP-MS measurements were < 0.06% and around 0.1%, respectively. This method enabled us to determine strontium and lead isotope ratios in two days. (author)

  3. Determination of lead and arsenic in tobacco and cigarettes: an important issue of public health.

    Science.gov (United States)

    Lazarević, Konstansa; Nikolić, Dejan; Stosić, Ljiljana; Milutinović, Suzana; Videnović, Jelena; Bogdanović, Dragan

    2012-03-01

    Contents of lead and arsenic were determined in 617 tobacco samples and 80 samples of cigarettes. The mean content of lead in tobacco was 0.93 microg/g (range 0.02-8.56 microg/g) and arsenic was 0.15 microg/g (range arsenic was 0.11 microg/g (range arsenic content among samples of tobacco and samples of cigarettes. Positive correlation between lead and arsenic contents in tobacco was found (r = 0.22; p arsenic in tobacco and cigarettes in other studies and discuss the influence of smoking to lead and arsenic exposure and health. In conclusion, at the same time with the implementation of tobacco use prevention programmes it is advisable to implement continuous monitoring of lead and arsenic in tobacco and cigarettes in order to reduce the health risk due to exposure of these metals.

  4. Transition of cord blood lead level, 1985-2002, in the Taipei area and its determinants after the cease of leaded gasoline use

    International Nuclear Information System (INIS)

    Hwang, Y.-H.; Ko Yi; Chiang, C.-D.; Hsu, S.-P.; Lee, Y.-H.; Yu, C.-H.; Chiou, C.-H.; Wang, J.-D.; Chuang, H.-Y.

    2004-01-01

    Lead has long been of concern for its toxicity, impairment of neurobehavioral and cognitive development, and electrophysiological deficits in children, even at levels less than 10 μg/dL. The present study was conducted to elucidate the extent of cord blood lead level decline in the Taipei area from 1985 to 2002 and to explore the factors affecting the cord blood lead level after the cease of leaded gasoline use. In the current study period of 2001-2002, 184 of 1310 newborns delivered in the Taipei Municipal Women and Children Hospital between September 2001 and August 2002 were eligible and randomly selected to participate in this study. Neither of their parents had an occupational lead exposure history. At each delivery, a sample of 5-10 mL umbilical cord blood was collected for lead determination by graphite furnace atomic absorption spectrometry. The cord blood lead level of the newborns in the current study period averaged 2.35±1.12 μg/dL. Together with the cord blood lead averages of 7.48±2.25 and 3.28±1.52 μg/dL obtained from two previous surveys conducted in 1985-1987 and 1990-1992, respectively, the cord blood lead level was significantly decreased (P<0.005). It is estimated that such a reduction in cord blood lead from 7.48 to 2.35 μg/dL for each year's cohort of 260,000 newborns in Taiwan might benefit the economics, ranging from US$8.9 billion to US$12.1 billion by improving the worker productivity. For the time period from 1985 to 2002, there were consistent transition patterns among the yearly fluctuations of air lead level, leaded gasoline consumption, lead content in gasoline, estimated lead amount emitted from the consumed leaded gasoline, and average cord blood lead levels of the three respective study periods. Additionally, every 0.1-g/L reduction in lead content in gasoline might lead to a lowering of cord blood lead level by 1.78 μg/dL. Furthermore, at low level of around 2 μg/dL, a multiple regression analysis demonstrated that

  5. Lead distribution in soils impacted by a secondary lead smelter: Experimental and modelling approaches

    Energy Technology Data Exchange (ETDEWEB)

    Schneider, Arnaud R., E-mail: arnaud.schneider@univ-reims.fr [GEGENAA, EA 3795, Université de Reims Champagne-Ardenne, SFR Condorcet FR CNRS 3417, 2 esplanade Roland Garros, 51100 Reims (France); Cancès, Benjamin; Ponthieu, Marie [GEGENAA, EA 3795, Université de Reims Champagne-Ardenne, SFR Condorcet FR CNRS 3417, 2 esplanade Roland Garros, 51100 Reims (France); Sobanska, Sophie [Laboratoire de Spectrochimie IR et Raman, UMR-CNRS 8516, Bât. C5 Université de Lille I, 59655 Villeneuve d' Ascq Cedex (France); Benedetti, Marc F. [Institut de Physique du Globe de Paris, Sorbonne Paris Cité, Université Paris Diderot, UMR 7154, CNRS, F-75005 Paris (France); Pourret, Olivier [HydrISE, Institut Polytechnique LaSalle Beauvais, FR-60000 Beauvais (France); Conreux, Alexandra; Calandra, Ivan; Martinet, Blandine; Morvan, Xavier; Gommeaux, Maxime; Marin, Béatrice [GEGENAA, EA 3795, Université de Reims Champagne-Ardenne, SFR Condorcet FR CNRS 3417, 2 esplanade Roland Garros, 51100 Reims (France)

    2016-10-15

    Smelting activities are one of the most common sources of trace elements in the environment. The aim of this study was to determine the lead distribution in upper horizons (0–5 and 5–10 cm) of acidic soils in the vicinity of a lead-acid battery recycling plant in northern France. The combination of chemical methods (sequential extractions), physical methods (Raman microspectroscopy and scanning electron microscopy with an energy dispersive spectrometer) and multi-surface complexation modelling enabled an assessment of the behaviour of Pb. Regardless of the studied soil, none of the Pb-bearing phases commonly identified in similarly polluted environments (e.g., anglesite) were observed. Lead was mainly associated with organic matter and manganese oxides. The association of Pb with these soil constituents can be interpreted as evidence of Pb redistribution in the studied soils following smelter particle deposition. - Highlights: • Lead behavior was studied in smelter impacted soils. • A combination of experimental methods and modelling was employed. • Pb was mainly associated with organic matter and to a lesser degree with Mn oxides. • Pb was redistributed in soils after smelter particle deposition.

  6. Lead distribution in soils impacted by a secondary lead smelter: Experimental and modelling approaches

    International Nuclear Information System (INIS)

    Schneider, Arnaud R.; Cancès, Benjamin; Ponthieu, Marie; Sobanska, Sophie; Benedetti, Marc F.; Pourret, Olivier; Conreux, Alexandra; Calandra, Ivan; Martinet, Blandine; Morvan, Xavier; Gommeaux, Maxime; Marin, Béatrice

    2016-01-01

    Smelting activities are one of the most common sources of trace elements in the environment. The aim of this study was to determine the lead distribution in upper horizons (0–5 and 5–10 cm) of acidic soils in the vicinity of a lead-acid battery recycling plant in northern France. The combination of chemical methods (sequential extractions), physical methods (Raman microspectroscopy and scanning electron microscopy with an energy dispersive spectrometer) and multi-surface complexation modelling enabled an assessment of the behaviour of Pb. Regardless of the studied soil, none of the Pb-bearing phases commonly identified in similarly polluted environments (e.g., anglesite) were observed. Lead was mainly associated with organic matter and manganese oxides. The association of Pb with these soil constituents can be interpreted as evidence of Pb redistribution in the studied soils following smelter particle deposition. - Highlights: • Lead behavior was studied in smelter impacted soils. • A combination of experimental methods and modelling was employed. • Pb was mainly associated with organic matter and to a lesser degree with Mn oxides. • Pb was redistributed in soils after smelter particle deposition.

  7. In vivo x-ray fluorescence of lead and other toxic trace elements

    International Nuclear Information System (INIS)

    Chettle, D.R.

    1995-01-01

    The first in vivo x-ray fluorescence measurements of lead in bone used y-rays from a 57 Co source to excite Pb K x-rays. Later systems used γ-rays from 109 Cd to excite Pb K x-rays or polarized x-rays to excite Ph L x-rays. All three approaches involve an extremely low effective dose to the subject. Of the two K x-ray techniques, 109 Cd is more precise and more flexible in choice of measurement site. Pb L x-ray fluorescence (L-XRF) effectively samples lead at bone surfaces, whereas Ph K x-ray fluorescence (K-XRF) samples through the bulk of a bone. Both the polarized L-XRF and 109 Cd K-XRF achieve similar precision. Renal mercury has recently been determined using a polarized x-ray source, Both renal and hepatic cadmium can be measured using polarized x-rays in conjunction with a Si(Li) detector. Platinum and gold have been measured both by radioisotopic source excitation and by using polarized x-rays, but the latter is to be preferred. Applications of Pb K-XRF have shown that measured bone lead relates strongly to cumulative lead exposure. Secondly, biological half lives of lead in different bone types have been estimated from limited longitudinal data sets and from some cross sectional surveys. Thirdly, the effect of bone lead as an endogenous source of lead has been demonstrated and it has been shown that a majority of circulating blood lead can be mobilized from bone, rather than deriving from new exposure, in some retired lead workers. 35 refs., 5 tabs

  8. Lead isotope ratios as a tracer for lead contamination sources: A lake Andong case study

    Directory of Open Access Journals (Sweden)

    Kim Y. H

    2013-04-01

    Full Text Available The objective of this study was to evaluate stable Pb isotope signatures as a tracer for Pb contamination in Lake Andong. For Pb isotope analysis, we collected water and sediment from Lake Andong, particles in the air, soils, and stream water, mine tailings, sludge and wastewater from zinc smelting around lake Andong watershed. The results showed that Pb isotope ratios (206Pb/204Pb, 207Pb/204Pb, and 208Pb/204Pb for zinc concentrate were 18.809 ± 0.322, 15.650 ± 0.062, and 38.728 ± 0.421, respectively. In wastewater, isotopic ratio values (206Pb/204Pb, 207Pb/204Pb, and 208Pb/204Pb were 17.363 ± 0.133, 15.550 ± 0.025, and 37.217 ± 0.092, respectively. Additionally, isotopic ratio values (206Pb/204Pb, 207Pb/204Pb, and 208Pb/204Pb for sludge were 17.515 ± 0.155, 15.537 ± 0.018, and 37.357 ± 0.173, respectively. These values were similar to those in zinc and lead concentrate originated from Canada and South America. In contrast, Pb isotope ratios of soil, tailings and sediment from Lake Andong were similar to those of Korean ore. Atmospheric particles showed different patterns of Pb isotope ratios from sediments, soils, and zinc smelting and this needs further investigation in order to identify atmospheric Pb sources.

  9. English language YouTube videos as a source of lead poisoning-related information: a cross-sectional study.

    Science.gov (United States)

    Basch, Corey H; Jackson, Ashley M; Yin, Jingjing; Hammond, Rodney N; Adhikari, Atin; Fung, Isaac Chun-Hai

    2017-07-01

    Exposure to lead is detrimental to children's development. YouTube is a form of social media through which people may learn about lead poisoning. The aim of this cross-sectional study was to analyze the variation in lead poisoning-related YouTube contents between different video sources. The 100 most viewed lead poisoning-related videos were manually coded, among which, 50 were consumer-generated, 19 were created by health care professionals, and 31 were news. The 100 videos had a total of more than 8.9 million views, with news videos accounting for 63% of those views. The odds of mentioning what lead poisoning is, how to remove lead, and specifically mentioning the danger in ages 1-5 because of rapid growth among videos created by health care professionals were 7.28 times (Odds ratio, OR = 7.28, 95% CI, 2.09, 25.37, p = 0.002); 6.83 times (OR = 6.83, 95% CI, 2.05, 22.75, p = 0.002) and 9.14 times (OR = 9.14, CI, 2.05, 40.70, p = 0.004) that of consumer-generated videos, respectively. In this study, professional videos had more accurate information regarding lead but their videos were less likely to be viewed compared to consumer-generated videos and news videos. If professional videos about lead poisoning can attract more viewers, more people would be better informed and could possibly influence policy agendas, thereby helping communities being affected by lead exposure.

  10. Arkansas People Participating in Lead Education (APPLE): results of a lead-safe training program.

    Science.gov (United States)

    Ferguson, Alesia; Bursac, Zoran; Kern, David F

    2011-06-01

    Lead is still seen as one of the most harmful environmental toxins for young children, with the predominant source being deteriorating lead-based paint. Those at continued risk include those living in homes built before 1978, renovators and remodelers, and especially those with limited access to proper healthcare and diets. Proper training on lead-safe work practices focused on preventing and reducing the spread of lead dust can help reduce lead exposure. Presented in this paper are experiences in delivering lead-safe work practices training in six Arkansas cities, and results from pre- and post- surveys delivered before and immediately after the training. Pre- and post-surveys assess strong and weak areas of training. Participants demonstrated positive shifts in attitude and behavior towards lead-safe work practices following training. However, our research found that more emphasis should be focused on clarifying current lead exposure sources and routes for children.

  11. Dose rate reduction using epoxy mixed lead shielding: experimental and theoretical determination of its shielding effectiveness

    International Nuclear Information System (INIS)

    Yadav, R.K.B.; Prasad, S.K.; Babu, K.S.; Hardiya, M.R.; Ullas, O.P.

    2010-01-01

    Full text: High background radiation field exists in Water Treatment Area (WTA) of Rod Cutting Building (RCB) in Cirus due to beta, gamma contamination on its floor. The high contamination on sides of wall and on floor is primarily due to deposition of activity generated during the regeneration of old mixed bed cartridges earlier (before year 1985) and presently due to deposition of contaminants by sump overflowing, wastes generated during maintenance/servicing of circulating pumps. RCB-WTA contribution to collective dose in present situation is up to 30% of the total collective dose of Cirus. Various options such as chipping of top layer of concrete floor of a sample area, in-situ placing of slab of cement and lead shot mixture were considered. In this case the man-rem consumption was high as radiation dose rate on concrete chip was 0.4 mGy/h and air activity generated was high, that too long lived with 137 Cs-as main constituent. The dose reduction factor was 1.7. In the second option the reduction in dose rate was insignificant and in-situ pouring of concrete consumed high collective dose. Hence above two options were not acceptable. Therefore the idea of tiling the contaminated floor with prefabricated epoxy mixed lead shots was accepted from ALARA point of view. It was concluded that pre-fabricated slabs of epoxy mixed lead slab of 25 mm thickness can be laid in RCB area to achieve a dose rate reduction factor of approximately five at a height of 30 cm above floor. This will result in a reduction of Person-mSv consumption in RCB by a factor of 5-10. These slabs of different thickness were fabricated outside RCB and were tested for shielding effectiveness experimentally by using radiation source and theoretically using MCNP code. Dose reduction factor of five for a point source, obtained experimentally for epoxy mixed lead shots was very near to value obtained by theoretical simulation. An extended calculation for an area source using this MCNP model gives a

  12. Structure determination and compositional modification of body-centered tetragonal PX-phase lead titanate

    Czech Academy of Sciences Publication Activity Database

    Wang, J.; Schenk, K.; Carvalho, A.; Wylie-van Eerd, B.; Trodahl, J.; Sandu, C.S.; Bonin, M.; Gregora, Ivan; He, Z.; Yamada, T.; Funakubo, H.; Briddon, P.R.; Setter, N.

    2011-01-01

    Roč. 23, č. 10 (2011), s. 2529-2535 ISSN 0897-4756 R&D Projects: GA AV ČR KAN301370701 Institutional research plan: CEZ:AV0Z10100520 Keywords : lead titanate * fibrous PX phase * structure determination * open channels * Raman scattering Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 7.286, year: 2011

  13. Evaluation of neutron shielding properties of lead glass using bubble detector

    International Nuclear Information System (INIS)

    Viswanathan, S.; Vishwa Prasad, K.; Srinivasan, T.K.; Ponraju, D.

    1999-01-01

    Neutron shielding properties of lead glass had been studied using a 241 Am-Be neutron source. Indigenously developed bubble detector was used as neutron detector. Attenuation curves were determined experimentally for the lead glass under the conditions of broad beam geometry. Theoretical calculations were made using Monte Carlo code MCNP3. Measurements were made for polyethylene and concrete to serve as reference. The measured and calculated neutron removal cross sections of lead glass, polyethylene and concrete are reported in this paper. Good agreement is observed between the experimental results and theoretical calculations. (author)

  14. A fast atom bombardment study of the lead isotope ratios in early nineteenth century Niagara Peninsula pottery glazes

    International Nuclear Information System (INIS)

    Miller, J.M.; Jones, T.R.B.; Kenney, Tina; Rupp, D.W.

    1986-01-01

    The application of fast atom bombardment (FAB) mass spectrometry to the determination of lead isotope ratios in nineteenth century pottery glazes from the Niagara Peninsula has been investigated with the aim of determining the source of the lead used in the glazes. Methods of sampling have been compared, including direct analysis of glass chips, analysis of powdered glaze scrapings, analysis of acid extracts of the former, and simple acid leaching of the surface of a piece of pottery. The latter method gave the best results. The FAB data, as obtained on an older mass spectrometer, can distinguish lead from igneous vs. sedimentary deposits, but is not adequate to determine specific mining locations. Although newer FAB instrumentation can narrow this range, the overlap of data from the Niagara Peninsula and England precludes a simple answer to the archeological question as to English vs. Canadian origin of the lead used in the Jordan pottery glazes. However, the data do suggest that the potter used a local source for the lead

  15. Determination of the silver content in some ancient coins using an Am-Be neutron source

    International Nuclear Information System (INIS)

    Cosma, C.; Fiat, T.; Znamizovschi, V.; Daraban, L.; Morariu, V.; Boros, D.; Alicu, D.

    1985-01-01

    The silver content of 40 Roman and Greek coins was determined using neutron activation analysis. with an M-Be thermal source. The pure silver standard had a weigth and shape similar to those of the analyzed coins. A monopchannel spectrometer with a NaI(Tl), 45x40 mm scintillator crystal was used. The coins were placed at the center of the entrance window of the crystal, the maximum measuring geometry being about 2π. A VA-5-968 scintillation probe was used, placed in a VA-H-161 lead shield in order to reduce the background of the detector. The irradiation time, cooling time and measuring time were 2 min, 20 sec and 1 min correspondingly. The ratio of counting rates for the standard material and the background was 2,5. The experimental errors were about 5% for concentrations higher than 50% and increasingly higher for lower silver concentrations

  16. Determination of a source term for a time fractional diffusion equation with an integral type over-determining condition

    Directory of Open Access Journals (Sweden)

    Timurkhan S. Aleroev

    2013-12-01

    Full Text Available We consider a linear heat equation involving a fractional derivative in time, with a nonlocal boundary condition. We determine a source term independent of the space variable, and the temperature distribution for a problem with an over-determining condition of integral type. We prove the existence and uniqueness of the solution, and its continuous dependence on the data.

  17. Determining the VLF/ULF source height using phase measurements

    Science.gov (United States)

    Ryabov, A.; Kotik, D. S.

    2012-12-01

    Generation of ULF/VLF waves in the ionosphere using powerful RF facilities has been studied for the last 40 years, both theoretically and experimentally. During this time, it was proposed several mechanisms for explaining the experimental results: modulation of ionospheric currents based on thermal nonlinearity, ponderomotive mechanisms for generation both VLF and ULF signals, cubic nonlinearity, etc. According mentioned above mechanisms the VLF/ULF signal source could be located in the lower or upper ionosphere. The group velocity of signal propagation in the ionosphere is significantly smaller than speed of light. As a result the appreciable time delay of the received signals will occur at the earth surface. This time delay could be determine by measuring the phase difference between received and reference signals, which are GPS synchronized. The experiment on determining the time delay of ULF signal propagation from the ionospheric source was carried out at SURA facility in 2012 and the results are presented in this paper. The comparison with numerical simulation of the time delay using the adjusted IRI model and ionosonde data shows well agreement with the experimental observations. The work was supported by RFBR grant 11-02-00419-a and RF Ministry of education and science by state contract 16.518.11.7066.

  18. Lead levels in deciduous teeth of children in Bahrain.

    Science.gov (United States)

    al-Mahroos, F; al-Saleh, F S

    1997-06-01

    To determine lead exposure among children in Bahrain, a total of 280 shed deciduous whole teeth were collected from 269 children. Teeth were analyzed for lead concentrations using atomic absorption spectrophotometry with electrothermal atomization. Children were between 5 and 15 years old. The study period extended from July 1993 to April 1994. The study showed that the overall mean tooth-lead level was 4.3 micrograms/g dry weight with a range of 0.1-60.8 micrograms/g dry weight. The cumulative frequency distribution revealed that 35% of the teeth had a lead concentration of more than 4 micrograms/g dry weight. The tooth-lead concentrations differed according to the tooth type age. The child's sex, nationality, area of residence and socio-economic status had no impact on tooth-lead level. In conclusion, lead is present in toxic concentrations in 35% of the teeth of the children studied. Urgent measures are needed to eliminate lead from gasoline, paint and other sources in the environment.

  19. Determinants, obstacles, sources and cooperation to innovation in Portuguese firms, using community innovation survey

    Science.gov (United States)

    Correia, Aldina; Braga, Alexandra; Braga, Vitor

    2017-06-01

    Innovation is a topic of interest for the management researchers, confirmed by the creation of a Community Innovation Survey, which is an harmonised tool designed to provide information about Innovation in European Union enterprises. In this study, we use factorial analysis to identify the determinants and obstacles to innovation in Portuguese firms. The sources of innovation and cooperation to innovation are also analysed, using crossed information. For the determinants of innovation six factors were identified: Production costs and impacts to health and environment, Process and product innovation, Organizational innovation, Institutional sources of information, Others sources of information and Market sources of information. Obstacles to innovation were clustered into three groups: Knowledge and market factors, Cost factors and Reasons not to innovate. The main sources of innovation identified, in this study, are Suppliers and Clients, located in Portugal and in Europe. Cooperation partners are also majority Clients and Suppliers, in addition to other enterprises in the same group.

  20. Biological fractionation of lead isotopes in Sprague-Dawley rats lead poisoned via the respiratory tract.

    Directory of Open Access Journals (Sweden)

    Jing Wu

    Full Text Available It was considered that lead isotope ratios did not change during physical, chemical, or biological processes. Thus, lead isotope ratios have been used as fingerprints to identify possible lead sources. However, recent evidence has shown that the lead isotope ratios among different biological samples in human are not always identical from its lead origins in vitro. An animal experiment was conducted to explore the biological fractionation of lead isotopes in biological systems.24 male Sprague-Dawley (SD rats were divided into groups that received acute lead exposure (0, 0.02, 0.2, or 2 mg/kg body weight of lead acetate via the respiratory route every day for 5 days. Biological samples (i.e., blood, urine, and feces were collected for comparison with the lead acetate (test substance and the low-lead animal feed (diet administered to the rats. The lead isotope ratios were determined by inductively coupled plasma mass spectrometry (ICP-MS.There are significant differences (p<0.05 in lead isotope ratios between blood, urine, and feces. Moreover, a nonlinear relationship between the blood lead concentration and the blood lead isotope ratios was observed. There is also a threshold effect to the fractionation function. Only the blood isotope ratio of (204Pb/(206Pb matches the test substance well. As for feces, when (204Pb/(206Pb ratio is considered, there is no significant difference between feces-test substance pairs in medium and high dose group.The biological fractionation of lead isotopes in SD rats was observed. Moreover, there might be a threshold for the biological fractionation of lead isotopes which is depending on whole blood lead level. It is considered to be more reliable that we compared the isotope ratios of potential lead hazards with both blood and feces lead fingerprints especially for (204Pb/(206Pb ratio under high-dose exposure.

  1. Event Coverage Detection and Event Source Determination in Underwater Wireless Sensor Networks

    Directory of Open Access Journals (Sweden)

    Zhangbing Zhou

    2015-12-01

    Full Text Available With the advent of the Internet of Underwater Things, smart things are deployed in the ocean space and establish underwater wireless sensor networks for the monitoring of vast and dynamic underwater environments. When events are found to have possibly occurred, accurate event coverage should be detected, and potential event sources should be determined for the enactment of prompt and proper responses. To address this challenge, a technique that detects event coverage and determines event sources is developed in this article. Specifically, the occurrence of possible events corresponds to a set of neighboring sensor nodes whose sensory data may deviate from a normal sensing range in a collective fashion. An appropriate sensor node is selected as the relay node for gathering and routing sensory data to sink node(s. When sensory data are collected at sink node(s, the event coverage is detected and represented as a weighted graph, where the vertices in this graph correspond to sensor nodes and the weight specified upon the edges reflects the extent of sensory data deviating from a normal sensing range. Event sources are determined, which correspond to the barycenters in this graph. The results of the experiments show that our technique is more energy efficient, especially when the network topology is relatively steady.

  2. Biological fractionation of lead isotopes in Sprague-Dawley rats lead poisoned via the respiratory tract.

    Science.gov (United States)

    Wu, Jing; Liu, Duojian; Xie, Qing; Wang, Jingyu

    2012-01-01

    It was considered that lead isotope ratios did not change during physical, chemical, or biological processes. Thus, lead isotope ratios have been used as fingerprints to identify possible lead sources. However, recent evidence has shown that the lead isotope ratios among different biological samples in human are not always identical from its lead origins in vitro. An animal experiment was conducted to explore the biological fractionation of lead isotopes in biological systems. 24 male Sprague-Dawley (SD) rats were divided into groups that received acute lead exposure (0, 0.02, 0.2, or 2 mg/kg body weight of lead acetate) via the respiratory route every day for 5 days. Biological samples (i.e., blood, urine, and feces) were collected for comparison with the lead acetate (test substance) and the low-lead animal feed (diet) administered to the rats. The lead isotope ratios were determined by inductively coupled plasma mass spectrometry (ICP-MS). There are significant differences (pblood, urine, and feces. Moreover, a nonlinear relationship between the blood lead concentration and the blood lead isotope ratios was observed. There is also a threshold effect to the fractionation function. Only the blood isotope ratio of (204)Pb/(206)Pb matches the test substance well. As for feces, when (204)Pb/(206)Pb ratio is considered, there is no significant difference between feces-test substance pairs in medium and high dose group. The biological fractionation of lead isotopes in SD rats was observed. Moreover, there might be a threshold for the biological fractionation of lead isotopes which is depending on whole blood lead level. It is considered to be more reliable that we compared the isotope ratios of potential lead hazards with both blood and feces lead fingerprints especially for (204)Pb/(206)Pb ratio under high-dose exposure.

  3. Isotope systematic of contaminant leads in Monterey Bay

    International Nuclear Information System (INIS)

    Flegal, A.R.; Rosman, K.J.R.; Stephenson, M.D.

    1987-01-01

    Isotopic compositions of stable lead ( 204 Pb, 206 Pb, 207 Pb, and 208 Pb) were utilized to identify a lead slag deposit as the principal source of contaminant lead in Monterey Bay. This point source had been indicated by anomalously high lead concentrations in native mussels (Mytilus californianus) near that deposit, which were orders of magnitude above the base-line concentration of the species (0.5 μg/g). Subsequent analyses revealed that the lead concentrations of both transplanted mussels and intertidal sediments were positively correlated with their proximity to the slag deposit. Complementary lead isotopic compositions substantiated those empirical correlations by demonstrating that the slag was the predominant source of contaminant lead in both the mussels and the sediments. Analyses of the digestive tracts of mussels from the slag deposit indicated that ingested slag particulates accounted for their elevated lead concentrations, while analyses of their gonads indicated that dissolved lead from other industrial sources was also being bioaccumulated by passive adsorption on exposed surfaces. Therefore, this study has demonstrated the potential of lead isotope systematics both to identify sources of lead contamination in marine organisms and to trace its biogeochemical cycle in the marine environment. 26 references, 3 figures, 5 tables

  4. Lead contamination of inexpensive plastic jewelry

    Energy Technology Data Exchange (ETDEWEB)

    Yost, Jamie L. [Department of Chemistry, Ashland University, Ashland, Ohio (United States); Weidenhamer, Jeffrey D. [Department of Chemistry, Ashland University, Ashland, Ohio (United States)], E-mail: jweiden@ashland.edu

    2008-04-15

    The neurological hazards of lead to children are well-known. As a result of recent documented cases of lead poisoning, regulatory attention in the United States has focused on the lead content of children's metal jewelry. By contrast, little is known about the possible hazards of plastic jewelry items. The objective of this study was to determine whether inexpensive plastic jewelry is a possible source of toxic lead for children. Samples of more than 100 inexpensive plastic jewelry items were analyzed for lead content. Beads were screened by soaking in 1 M nitric acid. Nine items found to release more than 30 {mu}g of lead per bead were further tested for accessible lead, and scrapings of the bead coatings were analyzed for total lead content. The maximum accessible lead found was 49 {mu}g per bead, which is below the current US Consumer Product Safety Commission limit of 175 {mu}g. However, when the number of beads in each item was taken into account, six of the nine leaded samples contained more than 175 {mu}g accessible lead per item. The lead in these items appears to be associated with lead-based paints used to produce glossy coatings on imitation pearls and similar items. Coatings obtained by scraping individual beads contained 3.5-23% lead, which far exceeds the US regulatory limit of 0.06% lead in paints on items intended for children. Our results demonstrate that plastic jewelry items merit the attention of public health and consumer protection agencies seeking to limit the exposure of children to lead.

  5. Lead contamination of inexpensive plastic jewelry

    International Nuclear Information System (INIS)

    Yost, Jamie L.; Weidenhamer, Jeffrey D.

    2008-01-01

    The neurological hazards of lead to children are well-known. As a result of recent documented cases of lead poisoning, regulatory attention in the United States has focused on the lead content of children's metal jewelry. By contrast, little is known about the possible hazards of plastic jewelry items. The objective of this study was to determine whether inexpensive plastic jewelry is a possible source of toxic lead for children. Samples of more than 100 inexpensive plastic jewelry items were analyzed for lead content. Beads were screened by soaking in 1 M nitric acid. Nine items found to release more than 30 μg of lead per bead were further tested for accessible lead, and scrapings of the bead coatings were analyzed for total lead content. The maximum accessible lead found was 49 μg per bead, which is below the current US Consumer Product Safety Commission limit of 175 μg. However, when the number of beads in each item was taken into account, six of the nine leaded samples contained more than 175 μg accessible lead per item. The lead in these items appears to be associated with lead-based paints used to produce glossy coatings on imitation pearls and similar items. Coatings obtained by scraping individual beads contained 3.5-23% lead, which far exceeds the US regulatory limit of 0.06% lead in paints on items intended for children. Our results demonstrate that plastic jewelry items merit the attention of public health and consumer protection agencies seeking to limit the exposure of children to lead

  6. Determination of Trace Amounts of Lead with ETAAS After Single Drop Microextraction and Dispersive Liquid Liquid Microextraction Methods

    Directory of Open Access Journals (Sweden)

    Efeçınar M.

    2013-04-01

    Full Text Available Two liquid-phase microextraction procedures, single-drop microextraction (SDME and dispersive liquid–liquid microextraction (DLLME, have been developed for the determination of lead by electrothermal atomic absorption spectrometry (ETAAS. Both methods were based on the formation of lead iodide-Rhodamine B complex which is in phosphoric acid medium. In the presence of KI, anionic lead iodide was complexed with Rhodamine B as an ion-association complex. Several factors that may be affected on the SDME and DLLME methods were optimized. In the optimum experimental conditions, the limit of detection (3s and the enhancement factor were 0.008 μgL−1 and 152 for SDME and 0.0129 μgL−1 and 89 for DLLME respectively. The relative standard deviation (RSD for eight replicate determinations of 0.25 μgL−1 Pb was 4.6% for SDME and 0.5 μgL−1 Pb was 2.9% for DLLME. The developed methods were validated by the analysis of certified reference materials, and applied successfully to the determination of lead in several water and food samples.

  7. An exploratory study of lead recovery in lead-acid battery lifecycle in US market: An evidence-based approach

    International Nuclear Information System (INIS)

    Genaidy, A.M.; Sequeira, R.; Tolaymat, T.; Kohler, J.; Rinder, M.

    2008-01-01

    Background: This research examines lead recovery and recycling in lead-acid batteries (LAB) which account for 88% of US lead consumption. We explore strategies to maximize lead recovery and recycling in the LAB lifecycle. Currently, there is limited information on recycling rates for LAB in the published literature and is derived from a single source. Therefore, its recycling efforts in the US has been unclear so as to determine the maximum opportunities for metal recovery and recycling in the face of significant demands for LAB particularly in the auto industry. Objectives: The research utilizes an evidence-based approach to: (1) determine recycling rates for lead recovery in the LAB product lifecycle for the US market; and (2) quantify and identify opportunities where lead recovery and recycling can be improved. Methods: A comprehensive electronic search of the published literature was conducted to gather information on different LAB recycling models and actual data used to calculate recycling rates based on product lifecycle for the US market to identify strategies for increasing lead recovery and recycling. Results: The electronic search yielded five models for calculating LAB recycling rates. The description of evidence was documented for each model. Furthermore, an integrated model was developed to identify and quantify the maximum opportunities for lead recovery and recycling. Results showed that recycling rates declined during the period spanning from 1999 to 2006. Opportunities were identified for recovery and recycling of lead in the LAB product lifecycle. Concluding remarks: One can deduce the following from the analyses undertaken in this report: (1) lead recovery and recycling has been stable between 1999 and 2006; (2) lead consumption has increased at an annual rate of 2.25%, thus, the values derived in this study for opportunities dealing with lead recovery and recycling underestimate the amount of lead in scrap and waste generated; and (3) the

  8. Selective masking and demasking for the stepwise complexometric determination of aluminium, lead and zinc from the same solution

    Directory of Open Access Journals (Sweden)

    Singh Nahar

    2008-03-01

    Full Text Available Abstract Background A complexometric method based on selective masking and de-masking has been developed for the rapid determination of aluminium, lead and zinc from the same solution in glass and glass frit samples. The determination is carried out using potassium cyanide to mask zinc, and excess disodium salt of EDTA to mask lead and aluminium. The excess EDTA was titrated with standard Mn(IISO4 solution using Erichrome Black-T as the indicator. Subsequently selective de-masking agents – triethanolamine, 2,3-dimercaptopropanol and a formaldehyde/acetone mixture – were used to determine quantities of aluminium, lead and zinc in a stepwise and selective manner. Results The accuracy of the method was established by analysing glass certified reference material NBS 1412. The standard deviation of the measurements, calculated by analysing five replicates of each sample, was found to be less than 1.5% for the method proposed. Conclusion The novelty of the method lies in its simplicity and accuracy afforded by there not being a need for a prior separation or instrumentation. The proposed method was found to be highly selective for the precise determination of aluminum, zinc and lead in the routine analysis of glass batch and allied materials.

  9. Simultaneous Atomic Absorption Spectrometry for Cadmium and Lead Determination in Wastewater: A Laboratory Exercise

    Science.gov (United States)

    Correia, Paulo R. M.; Oliveira, Pedro V.

    2004-01-01

    The simultaneous determination of cadmium and lead by multi-element atomic absorption spectrometry with electrochemical atomization is proposed by employing a problem-based approach. The reports indicate that the students assimilated the principles of the simultaneous atomic absorption spectrometry (SIMAAS), the role of the chemical modifier, the…

  10. Determining lead concentration in the blood of primary school children in Damascus city and suburbs

    International Nuclear Information System (INIS)

    Al-Merey, R.; Al-Ghali, M.; Mortada, S.

    2006-01-01

    Due to the fact that lead is a relatively common element in nature and one of the most pollutant elements which man kind is exposed to in densely populated cities that have a large number of vehicles using leaded petrol which has bad effects on human health particularly children, it is found necessary to scan the health situation related to lead exposure in Damascus. The present work focuses on determining the concentration of lead in the blood of primary school children in Damascus city and some schools in the suburbs of Damascus. 546 blood samples were collected from school children in Damascus city and 183 blood samples from school children in the suburbs of Damascus. Parameters such as student's environmental, social and behavioral information were taken into consideration and correlate with lead concentration in students blood samples. Results showed that 76.3% of the samples have more than 10 μg/100 ml of lead in the blood. Which has lead to the following health effects: Decrease in hemoglobin and vitamin-D, Effects on central nervous system, Deterioration in children growth, decreasing in IQ, and kidney failure. (Authors)

  11. Determining lead concentration in the blood of primary school children in Damascus city and suburbs

    International Nuclear Information System (INIS)

    Al-Merey, R.; Galee, M.; Mortada, S.

    2005-05-01

    Due to the fact that lead is a relatively common element in nature and one of the most pollutant elements which man kind is exposed to in densely populated cities that have a large number of vehicles using leaded petrol which has bad effects on human health particularly children, it is found necessary to scan the health situation related to lead exposure in Damascus. The present work focuses on determining the concentration of lead in the blood of primary school children in Damascus city and some schools in the suburbs of Damascus. 546 blood samples were collected from school children in Damascus city and 183 blood samples from school children in the suburbs of Damascus. Parameters such as student's environmental, social and behavioral information were taken into consideration and correlate with lead concentration in students blood samples. Results showed that 76.3% of the samples have more than 10 μg/100 ml of lead in the blood. Which has lead to the following health effects: Decrease in hemoglobin and vitamin-D, Effects on central nervous system, Deterioration in children growth, decreasing in IQ, and kidney failure. (Authors)

  12. The determination of neutron energy spectra of radioisotope sources

    International Nuclear Information System (INIS)

    Lutkin, J.E.

    1975-08-01

    The neutron energy spectrum of a 241 Am-Be radioisotope neutron source has been determined by use of a time of flight neutron spectrometer; this spectrometer not being subject to the same uncertainties as a scintillation spectrometer. Neutron spectra have been determined using a scintillation spectrometer with which the effects of instrumental uncertainties, particularly the pulse shape discrimination have been assessed. In the course of the development of the time flight spectrometer a zero crossover pulse shape discrimination system was developed in order to reduce the unwanted background. Using this system a quantitative survey of pulse shape discrimination with experimental and commercial liquid and plastic organic scintillators were carried out. In addition the pulse shape discrimination properties of inorganic scintillators were also examined. (author)

  13. Determination of lead in environmental waters with dispersive liquid-liquid microextraction prior to atomic fluorescence spectrometry

    International Nuclear Information System (INIS)

    Zhou, Qingxiang; Zhao, Na; Xie, Guohong

    2011-01-01

    This paper established a new, rapid and sensitive method for the determination of lead in water samples preconcentrated by dispersive liquid-liquid microextraction (DLLME) prior to atomic fluorescence spectrometry. Dithizone was used as the chelating agent. In the DLLME procedure, lead formed lead-dithizone complex and migrated into the carbon tetrachloride micro-droplets. Important factors that would affect the extraction efficiency had been investigated including the kind and volume of extraction solvent and dispersive solvent, sample pH, the amount of chelating agent, extraction time and centrifugation time. The results showed that the coexisting ions containing in water samples had no obvious negative effect on the determination of lead. The experimental results indicated that the proposed method had a good linear range of 0.01-100 ng mL -1 (r 2 = 0.9990). The precision was 2.12% (RSD, n = 7) and the detection limit was 0.95 ng L -1 . Proposed method was validated with four real environmental samples and the results indicated that the proposed method was excellent for the future use and satisfied spiked recoveries were in the range of 92.9-97.4%.

  14. Measurement of lead compound in stack gas

    Energy Technology Data Exchange (ETDEWEB)

    Kobayashi, Y; Hori, M; Tanikawa, N

    1979-01-01

    The concentration and particle-size distribution of lead compounds in the exhaust gas from various stationary sources are examined. The stationary sources concern lead production from battery scraps, lead smelting of cable mold, steel production from iron scraps, plastic combustion furnace, and a heavy oil boiler. A lead concentration of 0.2-100 mg/cu m in exhaust gas is detected. Furthermore, exhaust gas lead compounds are affected by the raw materials used.

  15. Modeling and analysis for determining optimal suppliers under stochastic lead times

    DEFF Research Database (Denmark)

    Abginehchi, Soheil; Farahani, Reza Zanjirani

    2010-01-01

    systems. The item acquisition lead times of suppliers are random variables. Backorder is allowed and shortage cost is charged based on not only per unit in shortage but also per time unit. Continuous review (s,Q) policy has been assumed. When the inventory level depletes to a reorder level, the total...... order is split among n suppliers. Since the suppliers have different characteristics, the quantity ordered to different suppliers may be different. The problem is to determine the reorder level and quantity ordered to each supplier so that the expected total cost per time unit, including ordering cost...

  16. A survey of spatially distributed exterior dust lead loadings in New York City

    Energy Technology Data Exchange (ETDEWEB)

    Caravanos, Jack [Hunter College-CUNY, School of Health Sciences (United States); Weiss, Arlene L [Environmental Medicine Inc., 263 Center Avenue, Westwood, NJ 07675 (United States); School of Medicine, New York University, NY 10016 (United States); Blaise, Marc J [Hunter College-CUNY, School of Health Sciences (United States); Jaeger, Rudolph J [Environmental Medicine Inc., 263 Center Avenue, Westwood, NJ 07675 (United States) and School of Medicine, New York University, NY 10016 (United States)

    2006-02-15

    This work documents ambient lead dust deposition values (lead loading) for the boroughs of New York City in 2003-2004. Currently, no regulatory standards exist for exterior concentrations of lead in settled dust. This is in contrast to the clearance and risk assessment standards that exist for interior residential dust. The reported potential for neurobehavioral toxicity and adverse cognitive development in children due to lead exposure prompts public health concerns about undocumented lead sources. Such sources may include settled dust of outdoor origin. Dust sampling throughout the five boroughs of NYC was done from the top horizontal portion of pedestrian traffic control signals (PTCS) at selected street intersections along main thoroughfares. The data (n=214 samples) show that lead in dust varies within each borough with Brooklyn having the highest median concentration (730{mu}g/ft{sup 2}), followed in descending order by Staten Island (452{mu}g/ft{sup 2}), the Bronx (382{mu}g/ft{sup 2}), Queens (198{mu}g/ft{sup 2}) and finally, Manhattan (175{mu}g/ft{sup 2}). When compared to the HUD/EPA indoor lead in dust standard of 40{mu}g/ft{sup 2}, our data show that this value is exceeded in 86% of the samples taken. An effort was made to determine the source of the lead in the dust atop of the PTCS. The lead in the dust and the yellow signage paint (which contains lead) were compared using isotopic ratio analysis. Results showed that the lead-based paint chip samples from intact signage did not isotopically match the dust wipe samples taken from the same surface. We know that exterior dust containing lead contributes to interior dust lead loading. Therefore, settled leaded dust in the outdoor environment poses a risk for lead exposure to children living in urban areas, namely, areas with elevated childhood blood lead levels and background lead dust levels from a variety of unidentified sources.

  17. A survey of spatially distributed exterior dust lead loadings in New York City

    International Nuclear Information System (INIS)

    Caravanos, Jack; Weiss, Arlene L.; Blaise, Marc J.; Jaeger, Rudolph J.

    2006-01-01

    This work documents ambient lead dust deposition values (lead loading) for the boroughs of New York City in 2003-2004. Currently, no regulatory standards exist for exterior concentrations of lead in settled dust. This is in contrast to the clearance and risk assessment standards that exist for interior residential dust. The reported potential for neurobehavioral toxicity and adverse cognitive development in children due to lead exposure prompts public health concerns about undocumented lead sources. Such sources may include settled dust of outdoor origin. Dust sampling throughout the five boroughs of NYC was done from the top horizontal portion of pedestrian traffic control signals (PTCS) at selected street intersections along main thoroughfares. The data (n=214 samples) show that lead in dust varies within each borough with Brooklyn having the highest median concentration (730μg/ft 2 ), followed in descending order by Staten Island (452μg/ft 2 ), the Bronx (382μg/ft 2 ), Queens (198μg/ft 2 ) and finally, Manhattan (175μg/ft 2 ). When compared to the HUD/EPA indoor lead in dust standard of 40μg/ft 2 , our data show that this value is exceeded in 86% of the samples taken. An effort was made to determine the source of the lead in the dust atop of the PTCS. The lead in the dust and the yellow signage paint (which contains lead) were compared using isotopic ratio analysis. Results showed that the lead-based paint chip samples from intact signage did not isotopically match the dust wipe samples taken from the same surface. We know that exterior dust containing lead contributes to interior dust lead loading. Therefore, settled leaded dust in the outdoor environment poses a risk for lead exposure to children living in urban areas, namely, areas with elevated childhood blood lead levels and background lead dust levels from a variety of unidentified sources

  18. Determination of lead in human calculi and its effects on renal function of lead occupational workers

    International Nuclear Information System (INIS)

    Memon, F.; Vasandani, A.G.M.

    2016-01-01

    Seventy five samples of renal and eighteen samples of supra gingival calculi of lead recycling workers were collected over the period of seven years (2008-2014) and studied for the accumulation of lead. The results were compared with those of non exposed subjects. The lead content of calculi was investigated for its dependence on type and composition of calculi, blood lead, job status and duration of exposure. The effect of blood lead and renal calculi was also investigated in relation to kidney function of respective subjects. The mean lead levels of various types of calculi were found to follow the order as phosphate > oxalate > urate > cystine while single principal group of supra gingival calculi resulted in lower levels of metal. The lead content of calculi positively correlated with phosphate content of both of the renal (r = 0.655) and supra gingival calculi (r= 0.866). Impaired renal function was more pronounced in active workers and depended on blood lead levels in addition to presence of metal in renal calculi. (author)

  19. In vivo x-ray fluorescence of bone lead in the study of human lead metabolism: Serum lead, whole blood lead, bone lead, and cumulative exposure

    International Nuclear Information System (INIS)

    Cake, K.M.; Chettle, D.R.; Webber, C.E.; Gordon, C.L.

    1995-01-01

    Traditionally, clinical studies of lead's effect on health have relied on blood lead levels to indicate lead exposure. However, this is unsatisfactory because blood lead levels have a half-life of approximately 5 weeks, and thus reflect recent exposure. Over 90% of the lead body burden is in bone, and it is thought to have a long residence time, thus implying that measurements of bone lead reflect cumulative exposure. So, measurements of bone lead are useful in understanding the long-term health effects of lead. Ahlgren reported the first noninvasive measurements of bone lead in humans, where γ-rays from 57 Co were used to excite the K series x-rays of lead. The lead detection system at McMaster University uses a 109 Cd source which is positioned at the center of the detector face (HPGe) and a near backscatter (∼160 degrees) geometry. This arrangement allows great flexibility, since one can sample lead in a range of different bone sites due to a robust normalization technique which eliminates the need to correct for bone geometry, thickness of overlying tissue, and other related factors. The effective radiation dose to an adult during an x-ray fluorescence bone lead measurement is extremely low, being 35 nSv. This paper addresses the issue of how bone, whole blood, and serum lead concentrations can be related in order to understand a person's lead exposure history

  20. The determination of 800 to 30 μg lead(II) by potentiometric titration with molybdate

    International Nuclear Information System (INIS)

    Campiglio, A.

    1985-01-01

    The determination of 800 to 30 μg Pb(II) by potentiometric titration with molybdate by using a lead(II)-selective electrode was investigated. Under suitable conditions, 800 to 300 μg Pb(II) in aqueous solution by automatic or manual titration with 4x10 -3 M molybdate can be determined with an accuracy of +-0.57% and +-0.45% and a precision of +-0.43% and 0.30% (standard deviation = 0.25% and 0.17%, resp.). For determining amounts of Pb(II) below 300 μg, a 2x10 -3 M molybdate solution has to be used. Although 300 to 100μg Pb(II) are determinable again in water with satisfactory results, the titration in 40% ethanol is however more reliable: in this medium, amounts of 300 to 30μg Pb(II) can be determined with an accuracy of +-1% and a precision of +-2% (standard deviation from 20 titrations of 100μg Pb(II)=0.60%). The titration of 300-800μg Pb(II) in water and of 30-300μg Pb(II) in 40% ethanol is also possible in 0.1 M NaNO 3 sub- snd 0.1 M NaClO 4 sub- medium and can be used in the lead determination in organic compounds after mineralization with HNO 3 sub-HClO 4 sub-H 2 O 2 . (Author)

  1. A pre-concentration procedure using coprecipitation for determination of lead and iron in several samples using flame atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Saracoglu, S.; Soylak, M.; Peker, D.S. Kacar; Elci, L.; Santos, W.N.L. dos; Lemos, V.A.; Ferreira, S.L.C.

    2006-01-01

    The present paper proposes a pre-concentration procedure for determination of lead and iron in several samples by flame atomic absorption spectrometry. In it, lead(II) and iron(III) ions are coprecipitated using the violuric acid-copper(II) system as collector. Afterwards, the precipitate is dissolved with 1 M HNO 3 solution and the metal ions are determined. The optimization step was performed using factorial design involving the variables: pH, violuric acid mass (VA) and copper concentration (Cu). Using the optimized experimental conditions, the proposed procedure allows the determination these metals with detection limits of 0.18 μg L -1 for iron and 0.16 μg L -1 for lead. The effects of foreign ions on the pre-concentration procedure were also evaluated and the results demonstrated that this method could be applied for determination of iron and lead in several real samples. The proposed method was successfully applied to the analysis of seawater, urine, mineral water, soil and physiological solution samples. The concentrations of lead and iron achieved in these samples agree well with others data reported in the literature

  2. Monte Carlo simulations and measurements for efficiency determination of lead shielded plastic scintillator detectors

    Science.gov (United States)

    Yasin, Zafar; Negoita, Florin; Tabbassum, Sana; Borcea, Ruxandra; Kisyov, Stanimir

    2017-12-01

    The plastic scintillators are used in different areas of science and technology. One of the use of these scintillator detectors is as beam loss monitors (BLM) for new generation of high intensity heavy ion in superconducting linear accelerators. Operated in pulse counting mode with rather high thresholds and shielded by few centimeters of lead in order to cope with radiofrequency noise and X-ray background emitted by accelerator cavities, they preserve high efficiency for high energy gamma ray and neutrons produced in the nuclear reactions of lost beam particles with accelerator components. Efficiency calculation and calibration of detectors is very important before their practical usage. In the present work, the efficiency of plastic scintillator detectors is simulated using FLUKA for different gamma and neutron sources like, 60Co, 137Cs and 238Pu-Be. The sources are placed at different positions around the detector. Calculated values are compared with the measured values and a reasonable agreement is observed.

  3. Monetary benefits of preventing childhood lead poisoning with lead-safe window replacement

    OpenAIRE

    Nevin, Rick; Jacobs, David / E.; Berg, Michael; Cohen, Jonathan

    2007-01-01

    Previous estimates of childhood lead poisoning prevention benefits have quantified the present value of some health benefits, but not the costs of lead paint hazard control or the benefits associated with housing and energy markets. Because older housing with lead paint constitutes the main exposure source today in the U.S., we quantify health benefits, costs, market value benefits, energy savings, and net economic benefits of lead-safe window replacement (which includes paint stabilization ...

  4. Blood lead levels among rural Thai children exposed to lead-acid batteries from solar energy conversion systems.

    Science.gov (United States)

    Swaddiwudhipong, Witaya; Tontiwattanasap, Worawit; Khunyotying, Wanlee; Sanreun, Cherd

    2013-11-01

    We evaluate blood lead levels among Thai children to determine if exposure to lead-acid batteries is associated with elevated blood lead levels (EBLL). We screened 254 children aged 1-14 years old from 2 rural Thai villages for blood lead levels. We also screened 18 of 92 houses in these 2 villages for the presence of environmental lead. The overall prevalence of EBLL (> or = 10 microg/dl) was 43.3% and the mean lead level among study subjects was 9.8 +/- 5.1 microg/dl. The blood lead levels significantly decreased with increasing age. Fifty point eight percent of children who lived in a house with vented lead-acid batteries had EBLL while 23.3% of children who lived in a house without vented lead-acid batteries had EBLL. Multiple logistic regression analysis revealed a significant positive association between the presence of vented lead-acid batteries and EBLL, after adjusting for other variables. Forty-two point nine percent of house floor dust samples collected near the batteries had elevated lead levels, 7.1% of house floor dust samples collected from other areas in the house had elevated lead levels and 0% of the house floor dust samples collected in houses without vented lead-acid batteries had elevated lead levels. In the sampled houses with vented lead-acid batteries, lead contamination was found in the drinking-water kept in household containers, but not in the tap water or other village sources of water. Improper care and placement of vented lead-acid batteries can result in lead contamination in the home environment causing EBLL in exposed children.

  5. Determination of ring correction factors for leaded gloves used in grab sampling activities at Hanford tank farms

    International Nuclear Information System (INIS)

    RATHBONE, B.A.

    1999-01-01

    This study evaluates the effectiveness of lead lined gloves in reducing extremity dose from two sources specific to tank waste sampling activities: (1) sludge inside glass sample jars and (2) sludge as thin layer contamination on the exterior surface of sample jars. The response of past and present Hanford Extremity Dosimeters (ring) designs under these conditions is also evaluated

  6. Determination of ring correction factors for leaded gloves used in grab sampling activities at Hanford tank farms

    Energy Technology Data Exchange (ETDEWEB)

    RATHBONE, B.A.

    1999-06-24

    This study evaluates the effectiveness of lead lined gloves in reducing extremity dose from two sources specific to tank waste sampling activities: (1) sludge inside glass sample jars and (2) sludge as thin layer contamination on the exterior surface of sample jars. The response of past and present Hanford Extremity Dosimeters (ring) designs under these conditions is also evaluated.

  7. Natural Radionuclides and Isotopic Signatures for Determining Carbonaceous Aerosol Sources, Aerosol Lifetimes, and Washout Processes

    International Nuclear Information System (INIS)

    Gaffney, Jeffrey

    2012-01-01

    This is the final technical report. The project description is as follows: to determine the role of aerosol radiative forcing on climate, the processes that control their atmospheric concentrations must be understood, and aerosol sources need to be determined for mitigation. Measurements of naturally occurring radionuclides and stable isotopic signatures allow the sources, removal and transport processes, as well as atmospheric lifetimes of fine carbonaceous aerosols, to be evaluated.

  8. Natural Radionuclides and Isotopic Signatures for Determining Carbonaceous Aerosol Sources, Aerosol Lifetimes, and Washout Processes

    Energy Technology Data Exchange (ETDEWEB)

    Gaffney, Jeffrey [Univ. of Arkansas, Little Rock, AR (United States)

    2012-12-12

    This is the final technical report. The project description is as follows: to determine the role of aerosol radiative forcing on climate, the processes that control their atmospheric concentrations must be understood, and aerosol sources need to be determined for mitigation. Measurements of naturally occurring radionuclides and stable isotopic signatures allow the sources, removal and transport processes, as well as atmospheric lifetimes of fine carbonaceous aerosols, to be evaluated.

  9. Selective masking and demasking for the stepwise complexometric determination of aluminium, lead and zinc from the same solution

    OpenAIRE

    Kayal, Nijhuma; Singh, Nahar

    2008-01-01

    Abstract Background A complexometric method based on selective masking and de-masking has been developed for the rapid determination of aluminium, lead and zinc from the same solution in glass and glass frit samples. The determination is carried out using potassium cyanide to mask zinc, and excess disodium salt of EDTA to mask lead and aluminium. The excess EDTA was titrated with standard Mn(II)SO4 solution using Erichrome Black-T as the indicator. Subsequently selective de-masking agents – t...

  10. X-ray fluorescence determination of Sn, Sb, Pb in lead-based bearing alloys using a solution technique

    Science.gov (United States)

    Tian, Lunfu; Wang, Lili; Gao, Wei; Weng, Xiaodong; Liu, Jianhui; Zou, Deshuang; Dai, Yichun; Huang, Shuke

    2018-03-01

    For the quantitative analysis of the principal elements in lead-antimony-tin alloys, directly X-ray fluorescence (XRF) method using solid metal disks introduces considerable errors due to the microstructure inhomogeneity. To solve this problem, an aqueous solution XRF method is proposed for determining major amounts of Sb, Sn, Pb in lead-based bearing alloys. The alloy samples were dissolved by a mixture of nitric acid and tartaric acid to eliminated the effects of microstructure of these alloys on the XRF analysis. Rh Compton scattering was used as internal standard for Sb and Sn, and Bi was added as internal standard for Pb, to correct for matrix effects, instrumental and operational variations. High-purity lead, antimony and tin were used to prepare synthetic standards. Using these standards, calibration curves were constructed for the three elements after optimizing the spectrometer parameters. The method has been successfully applied to the analysis of lead-based bearing alloys and is more rapid than classical titration methods normally used. The determination results are consistent with certified values or those obtained by titrations.

  11. Hunting with lead: association between blood lead levels and wild game consumption.

    Science.gov (United States)

    Iqbal, Shahed; Blumenthal, Wendy; Kennedy, Chinaro; Yip, Fuyuen Y; Pickard, Stephen; Flanders, W Dana; Loringer, Kelly; Kruger, Kirby; Caldwell, Kathleen L; Jean Brown, Mary

    2009-11-01

    Wild game hunting is a popular activity in many regions of the United States. Recently, the presence of lead fragments in wild game meat, presumably from the bullets or shot used for hunting, has raised concerns about health risks from meat consumption. This study examined the association between blood lead levels (PbB) and wild game consumption. We recruited 742 participants, aged 2-92 years, from six North Dakota cities. Blood lead samples were collected from 736 persons. Information on socio-demographic background, housing, lead exposure source, and types of wild game consumption (i.e., venison, other game such as moose, birds) was also collected. Generalized estimating equations (GEE) were used to determine the association between PbB and wild game consumption. Most participants reported consuming wild game (80.8%) obtained from hunting (98.8%). The geometric mean PbB were 1.27 and 0.84 microg/dl among persons who did and did not consume wild game, respectively. After adjusting for potential confounders, persons who consumed wild game had 0.30 microg/dl (95% confidence interval: 0.16-0.44 microg/dl) higher PbB than persons who did not. For all game types, recent (game consumption was associated with higher PbB. PbB was also higher among those who consumed a larger serving size (> or = 2 oz vs. game' consumption only. Participants who consumed wild game had higher PbB than those who did not consume wild game. Careful review of butchering practices and monitoring of meat-packing processes may decrease lead exposure from wild game consumption.

  12. Determination of the pollution with lead in the batteries factory in Al-Saffera (Aleppo) and surrounding area

    International Nuclear Information System (INIS)

    Al-Oudat, M.; Al-Kharfan, K.; Al-Shamali, K.

    2007-10-01

    The study aimed to determine the lead concentrations in the ecosystem surrounding the batteries factory in Al-Saffera. The results showed that the lead levels were very high in both factory area and the surrounding agricultural area. Lead levels in air varied between 12 and 34 μg/m3 in the area outside the factory. The same trends were in both soil and plant samples, and normal washing does not decrease the lead level in plant samples to acceptable levels. Mean lead levels in blood was also high and ranged between 55 and 28 μg /dl for factory workers and village inhabitants respectively. In conclusion the authorities administration must take all necessary procedures to reduce the lead levels in the factory area and in the surrounding area.(Author)

  13. Determination of the pollution with lead in the batteries factory in Al-Saffera (Aleppo) and surrounding area

    Energy Technology Data Exchange (ETDEWEB)

    Al-Oudat, M; Al-Kharfan, K; Al-Shamali, K [Atomic Energy Commission, Damascus (Syrian Arab Republic), Dept. of Protection and Safety

    2007-10-15

    The study aimed to determine the lead concentrations in the ecosystem surrounding the batteries factory in Al-Saffera. The results showed that the lead levels were very high in both factory area and the surrounding agricultural area. Lead levels in air varied between 12 and 34 {mu}g/m3 in the area outside the factory. The same trends were in both soil and plant samples, and normal washing does not decrease the lead level in plant samples to acceptable levels. Mean lead levels in blood was also high and ranged between 55 and 28 {mu}g /dl for factory workers and village inhabitants respectively. In conclusion the authorities administration must take all necessary procedures to reduce the lead levels in the factory area and in the surrounding area.(Author)

  14. Determination of radium isotopes by BaSO4 coprecipitation for the preparation of alpha-spectrometric sources

    International Nuclear Information System (INIS)

    Lozano, J.C.; Fernandez, F.; Gomez, J.M.G.

    1997-01-01

    A coprecipitation procedure for the preparation of α-spectrometric sources for radium, using BaSO 4 as carrier, has been applied to the determination of alpha radium isotopes in water samples. The use of 133 Ba as a suitable tracer for radium determination and possible losses of radon isotopes from the sources are studied and discussed. (author)

  15. Lead distribution and possible sources along vertical zone spectrum of typical ecosystems in the Gongga Mountain, eastern Tibetan Plateau

    Science.gov (United States)

    Luo, Ji; Tang, Ronggui; Sun, Shouqin; Yang, Dandan; She, Jia; Yang, Peijun

    2015-08-01

    A total of 383 samples from soil, plant, litterfall and precipitation in four typical ecosystems of Gongga Mountain were collected. Pb concentrations of samples were measured and analyzed. The results showed mean Pb concentrations in different soil layers were in the order of O > A > C, and mean Pb concentrations of the aboveground parts of plant was 3.60 ± 2.54 mg kg-1, with the minimum value of 0.77 mg kg-1 and the maximum value of 10.90 mg kg-1. Pb concentrations in soil's O-horizon and A-horizon showed a downward trend with increasing elevation (the determination coefficient R2 was 0.9478, 0.7918 and 0.9759 respectively). In contrast to other soil layers, the level of Pb concentrations in O-horizon (incomplete decomposition) was significantly high. Litterfall decomposition, atmospheric deposition and the unique climate could be main factors leading high Pb accumulation in soil's O-horizon. What's more, significant correlation (R2 = 0.8126, P soil's A-horizon confirms that fine roots could adsorb and accumulate Pb materials in soil. In general, the fact that Pb inputted into the typical ecosystems in the Gongga Mountain via long-range transportation and deposition of the atmosphere from external Pb sources could be confirmed by the HYSPLIT model and the ratio of CPb/CAl in plants (leaves) and CPb/CAl in litterfall. The mining activities and increasing anthropogenic activities (tourism development) could be main sources of Pb in this area. In order to better understand Pb sources and eco-risks of these typical ecosystems, litterfall decomposition characteristics, biomass of productivity of forest ecosystem, Pb isotopic tracing among air mass, twigs, leaves, litterfall and O-horizon soil in this vertical belt should also be taken into consideration.

  16. Preventive maintenance basis: Volume 24 -- Battery -- flooded lead-acid (lead-calcium, lead antimony, plante). Final report

    International Nuclear Information System (INIS)

    Worledge, D.; Hinchcliffe, G.

    1997-12-01

    US nuclear power plants are implementing preventive maintenance (PM) tasks with little documented basis beyond fundamental vendor information to support the tasks or their intervals. The Preventive Maintenance Basis project provides utilities with the technical basis for PM tasks and task intervals associated with 40 specific components such as valves, electric motors, pumps, and HVAC equipment. This document provides a program of preventive maintenance tasks suitable for application to flooded lead-acid batteries. The PM tasks that are recommended provide a cost-effective way to intercept the causes and mechanisms that lead to degradation and failure. They can be used in conjunction with material from other sources, to develop a complete PM program or to improve an existing program. This document provides a program of preventive maintenance (PM) tasks suitable for application to flooded lead-acid batteries. The PM tasks that are recommended provide a cost-effective way to intercept the causes and mechanisms that lead to degradation and failure. They can be used, in conjunction with material from other sources, to develop a complete PM program or to improve an existing program. Users of this information will be utility managers, supervisors, system engineers, craft technicians, and training instructors responsible for developing, optimizing, or fine-tuning PM programs

  17. Stationary sources of airborne lead: a comparison of emissions data for southern California.

    Science.gov (United States)

    Harris, Allison R; Fifarek, Brian J; Davidson, Cliff I; Blackmon, Rebecca Lankey

    2006-04-01

    Estimates for the air releases of lead from stationary point sources are considered for the South Coast Air Basin of California. We have examined four databases published by U.S. Environmental Protection Agency, the California Air Resources Board, and the South Coast Air Quality Management District. Our analysis indicates that none of the databases includes every emitting facility in the South Coast Air Basin of California and that other discrepancies among the databases exist. Additionally, the data have been analyzed for temporal variation, and some of the California Air Resources Board data are not current. The South Coast Air Quality Management District inventory covers 12 times more facilities in 2001 than in 1996. From this analysis, we conclude that all four of the databases would benefit by sharing data, increasing transparency, analyzing uncertainty, and standardizing emission estimation methods.

  18. Development and validation of a novel, simple, and accurate spectrophotometric method for the determination of lead in human serum.

    Science.gov (United States)

    Shayesteh, Tavakol Heidari; Khajavi, Farzad; Khosroshahi, Abolfazl Ghafuri; Mahjub, Reza

    2016-01-01

    The determination of blood lead levels is the most useful indicator of the determination of the amount of lead that is absorbed by the human body. Various methods, like atomic absorption spectroscopy (AAS), have already been used for the detection of lead in biological fluid, but most of these methods are based on complicated, expensive, and highly instructed instruments. In this study, a simple and accurate spectroscopic method for the determination of lead has been developed and applied for the investigation of lead concentration in biological samples. In this study, a silica gel column was used to extract lead and eliminate interfering agents in human serum samples. The column was washed with deionized water. The pH was adjusted to the value of 8.2 using phosphate buffer, and then tartrate and cyanide solutions were added as masking agents. The lead content was extracted into the organic phase containing dithizone as a complexion reagent and the dithizone-Pb(II) complex was formed and approved by visible spectrophotometry at 538 nm. The recovery was found to be 84.6 %. In order to validate the method, a calibration curve involving the use of various concentration levels was calculated and proven to be linear in the range of 0.01-1.5 μg/ml, with an R (2) regression coefficient of 0.9968 by statistical analysis of linear model validation. The largest error % values were found to be -5.80 and +11.6 % for intra-day and inter-day measurements, respectively. The largest RSD % values were calculated to be 6.54 and 12.32 % for intra-day and inter-day measurements, respectively. Further, the limit of detection (LOD) was calculated to be 0.002 μg/ml. The developed method was applied to determine the lead content in the human serum of voluntary miners, and it has been proven that there is no statistically significant difference between the data provided from this novel method and the data obtained from previously studied AAS.

  19. Application of a Beamforming Technique to the Measurement of Airfoil Leading Edge Noise

    Directory of Open Access Journals (Sweden)

    Thomas Geyer

    2012-01-01

    Full Text Available The present paper describes the use of microphone array technology and beamforming algorithms for the measurement and analysis of noise generated by the interaction of a turbulent flow with the leading edge of an airfoil. Experiments were performed using a setup in an aeroacoustic wind tunnel, where the turbulent inflow is provided by different grids. In order to exactly localize the aeroacoustic noise sources and, moreover, to separate airfoil leading edge noise from grid-generated noise, the selected deconvolution beamforming algorithm is extended to be used on a fully three-dimensional source region. The result of this extended beamforming are three-dimensional mappings of noise source locations. Besides acoustic measurements, the investigation of airfoil leading edge noise requires the measurement of parameters describing the incident turbulence, such as the intensity and a characteristic length scale or time scale. The method used for the determination of these parameters in the present study is explained in detail. To demonstrate the applicability of the extended beamforming algorithm and the experimental setup as a whole, the noise generated at the leading edge of airfoils made of porous materials was measured and compared to that generated at the leading edge of a common nonporous airfoil.

  20. Determination of lead in water by electrothermal atomic absorption spectrometry with a nickel(II)-ammonium tartrate modifier

    International Nuclear Information System (INIS)

    Sekerka, I.; Lechner, J.F.

    1991-01-01

    A method is described for the determination of low concentrations of lead in water samples. Atomic absorption spectrometry is used with a tungsten ribbon furnace and Zeeman background correction. Interferences are eliminated by the addition of ammonium tartrate and nickel(II) nitrate to the samples to act as a matrix modifier and adjust the pH. The results show the superior performance of this modifier over other types used conventionally. The detection limit is 1 μg l -1 relative standard deviation of -1 can be obtained. The instrumentation is simple and the method is efficient for the determination of lead in various water samples. 25 refs.; 7 figs.; 6 tabs

  1. Right ventricle/interventricular septum electrophysiological anatomy (determination of optimal right ventricular lead placement

    Directory of Open Access Journals (Sweden)

    М. В. Диденко

    2015-10-01

    Full Text Available Notwithstanding a theoretically justified lead placement into the interventricular septum (IVS, the data from the clinical trials demonstrate somewhat controversial results. One of these controversies is the absence of consolidated criteria for positioning the electrode to deliver pacing from the interventricular septum (IVS area. The study describes anatomic features of RV and IVS with respect to the cardiac conduction system, normal ventricular excitation and electrode implantation techniques for continuous pacing. A comparative study of 73 specimens of cadaver hearts was carried out by using electro-anatomic 3D mapping of the heart, X-ray examination, computer-aided tomography, morphological and morphometric investigation. It was found out that the medium part of IVS in the septomarginal trabecula zone could be considered the best for continuous pacing. The criteria for the RV lead to be implanted in this zone were determined.

  2. Preparation and determination of kerma for Iridium 192 sources of low dose rate for brachytherapy

    International Nuclear Information System (INIS)

    Tendilla, J.I.; Tovar M, V.; Mitsoura, E.; Aguilar H, F.; Alanis M, J.

    2000-01-01

    The practice of Brachytherapy with Iridium-192 sources of low dose rate (0.4 - 0.8 Gy/h) is a technique used in the treatment of diverse illnesses. in this work the preparation, quality control and calibration are presented in terms of kerma in air of Iridium-192 using as target these recycled Iridium-Platinum wires. The targets were obtained as decayed sources of different radio therapeutical centers in the country and they were characterized by Scanning electron microscopy in order to determine their chemical composition. Subsequently it was developed an experimental design to establish the effect of neutron flux, geometrical array and irradiation time over the activity and percentage of the sources homogeneity. The homogeneity was determined by auto radiography and by Gamma spectroscopy. Once the optimal irradiation conditions were established, it is determined the apparent activity and kerma in air using a well type ionization chamber with traceability to a primary laboratory. Iridium-192 sources were obtained with an average homogeneity 96 %, apparent activity 282.129 ± 0.531 M Bq and kerma in air 0.03200 ± 0.00006 m Gy m/h A. (Author)

  3. High-precision Pb isotopic measurements of teeth and environmental samples from Sofia (Bulgaria): insights for regional lead sources and possible pathways to the human body

    Science.gov (United States)

    Kamenov, George D.

    2008-08-01

    High-precision Pb isotopic measurements on teeth and possible sources in a given area can provide important insights for the lead (Pb) sources and pathways in the human body. Pb isotopic analyses on soils from the area of Sofia, Bulgaria show that Pb is contributed by three end-members represented by two natural sources and leaded gasoline. Sequential leaching experiments reveal that the alumosilicate fraction of the soils is mainly controlled by natural Pb derived from two mountain massifs bordering the city. Around 1/3 to a half of the Pb in the soil leachates, however, can be explained by contamination from leaded gasoline. Contemporary teeth from Sofia residents show very similar Pb isotopic compositions to the soil leachates, also indicating that around 1/3 to a half of the Pb can be explained by derivation from leaded gasoline. The remarkable isotopic similarities between the teeth and the most labile fractions of the local soils suggest that the lead can be derived from the latter. Pb incorporation in the human body via soil-plant-human or soil-plant-animal-human chains is unlikely due to the fact that no significant farming occurs in the city area. The isotopic compositions of the local soil labile fractions can be used as approximation of the bioaccessible lead for humans. Considering all possible scenarios it appears that soil and/or soil-born dust inhalation and/or ingestion is the most probable pathway for incorporation of local soil lead in the local population. The high-precision Pb isotope data presented in this work indicate that apparently the local soil is what plays major role in the human Pb exposure.

  4. An experimental investigation of the shear-layer and acoustic sources produced by a leading edge slat

    Science.gov (United States)

    Wilkins, Stephen; Richard, Patrick; Hall, Joseph; Turbulence; Flow Noise Laboratory Team

    2013-11-01

    Leading edge slats are a common addition to airfoils as part of a high lift configuration employed during take-off and landing; the unsteady flow caused by these slats is a major contributor to the overal airframe noise. As the next generation of aircraft seeks to reduce these noise concerns, a better understanding of the sources of aeroacoustic noise generation is sought. Particle Image Velocimetry (PIV) and simultaneous multipoint measurements of the unsteady surface pressure are used herein to investigate the unsteady flow around a leading edge slat coupled with an airfoil for several different configurations and a range of Reynolds numbers (Re = 156 , 000 to Re = 1 . 2 million based on the wing chord). Shear-layer development off the slat cusp and the related unsteady vortex structures are examined in detail to better establish and understand the mechanisms responsible for the generation of aeroacoustic slat noise. The authors are grateful for the support provided by GARDN.

  5. Polyaniline–lead sulfate based cell with supercapattery behavior

    Directory of Open Access Journals (Sweden)

    Alsadek A. Alguail

    2017-07-01

    Full Text Available The electrochemically synthesized polyaniline and lead sulfate are investigated as a possible active material of the aqueous based hybrid asymmetric supercapacitors. The electrochemical characteristics of polyaniline (doping-dedoping reactions, as well as electrical characteristics (specific capacitance, capacity, energy, and power of the PbSO4|PANI cell, are determined. Based on the estimated specific energy and power, it is suggested that investigated cell could be classified as “supercapattery” type of electrochemical power sources.

  6. Intoxication from an accidentally ingested lead shot retained in the gastrointestinal tract.

    Science.gov (United States)

    Gustavsson, Per; Gerhardsson, Lars

    2005-04-01

    A 45-year-old woman was referred to the Department of Occupational and Environmental Health in January 2002 because of increased blood lead concentrations of unknown origin. She suffered from malaise, fatigue, and diffuse gastrointestinal symptoms. She had a blood lead level of 550 microg/L (normal range lead, and no potential lead sources, such as food products or lead-glazed pottery, could be identified. Her food habits were normal, but she did consume game occasionally. Clinical examination, including standard neurologic examination, was normal. No anemia was present. Laboratory tests showed an increased excretion of lead in the urine, but there were no signs of microproteinuria. An abdominal X ray in October 2002 revealed a 6-mm rounded metal object in the colon ascendens. Before the object could be further localized, the patient contracted winter vomiting disease (gastroenteritis) and the metal object was spontaneously released from the colon during a diarrhea attack. The object was a lead shot pellet, possibly but not normally used in Sweden for hunting wild boar or roe deer. Blood lead levels slowly decreased. Nine months later the patient's blood lead levels were almost normal (approximately 70 microg/L) and her symptoms had almost completely disappeared. In this case, a rare source of lead exposure was found. In investigations of blood lead elevations of unknown origin, we recommend abdominal X ray in parallel with repeated blood lead determinations.

  7. Determination of trace element concentrations and stable lead, uranium and thorium isotope ratios by quadrupole-ICP-MS in NORM and NORM-polluted sample leachates

    International Nuclear Information System (INIS)

    Mas, J.L.; Villa, M.; Hurtado, S.; García-Tenorio, R.

    2012-01-01

    Highlights: ► Polluted sediment and NORM samples. ► An efficient yet fast process allowing multi-parametric determinations in 206 Pb/ 207 Pb/ 208 Pb, 238 U/ 234 U and 232 Th/ 230 Th isotope ratios using a single sample aliquot and a single instrument (ICP-QMS). Eichrom UTEVA ® extraction chromatography minicolumns were used to separate uranium and thorium in sample leachates. Independent ICP-MS determinations of uranium and thorium isotope ratios were carried out afterwards. Previously a small aliquot of the leachate was used for the determination of trace element concentrations and lead isotope ratios. Several radiochemical arrangements were tested to get maximum performances and simplicity of the method. The performances of the method were studied in terms of chemical yields of uranium and thorium and removal of the potentially interfering elements. The established method was applied to samples from a chemical industry and sediments collected in a NORM-polluted scenario. The results obtained from our method allowed us to infer not only the extent, but also the sources of the contamination in the area.

  8. Determination of lead associated with airborne particulate matter by flame atomic absorption and wave-length dispersive x-ray fluorescence spectrometry

    International Nuclear Information System (INIS)

    Talebi, S.M.

    1997-01-01

    The lead content of airborne particulate matter was determined by flame atomic absorption spectrometry (FAAS) following digestion with a mixture of nitric acid and hydrogen peroxide and also by wave-length dispersive x-ray fluorescence (WDXRF). The extraction procedure was checked by analyzing a standard reference material of airborne particulate matter (NIST, SRM -1648). It was concluded that lead can quantitatively (98%) be extracted from airborne particulate matter by the leaching process. A five-stage sequential extraction was performed to assess the potential mobility of lead associated with airborne particulate matter. Comparison of the airborne particulate lead measured by WDXRF to that measured by FAAS showed good agreement. The WDXRF method requires no time-consuming sample preparation or use of environmentally unfriendly solvents. The technique is suggested for direct determination of lead in airborne particulate matter in air pollution studies. (author)

  9. Contaminated lead environments of man: reviewing the lead isotopic evidence in sediments, peat, and soils for the temporal and spatial patterns of atmospheric lead pollution in Sweden.

    Science.gov (United States)

    Bindler, Richard

    2011-08-01

    Clair Patterson and colleagues demonstrated already four decades ago that the lead cycle was greatly altered on a global scale by humans. Moreover, this change occurred long before the implementation of monitoring programs designed to study lead and other trace metals. Patterson and colleagues also developed stable lead isotope analyses as a tool to differentiate between natural and pollution-derived lead. Since then, stable isotope analyses of sediment, peat, herbaria collections, soils, and forest plants have given us new insights into lead biogeochemical cycling in space and time. Three important conclusions from our studies of lead in the Swedish environment conducted over the past 15 years, which are well supported by extensive results from elsewhere in Europe and in North America, are: (1) lead deposition rates at sites removed from major point sources during the twentieth century were about 1,000 times higher than natural background deposition rates a few thousand years ago (~10 mg Pb m(-2) year(-1) vs. 0.01 mg Pb m(-2) year(-1)), and even today (~1 mg Pb m(-2) year(-1)) are still almost 100 times greater than natural rates. This increase from natural background to maximum fluxes is similar to estimated changes in body burdens of lead from ancient times to the twentieth century. (2) Stable lead isotopes ((206)Pb/(207)Pb ratios shown in this paper) are an effective tool to distinguish anthropogenic lead from the natural lead present in sediments, peat, and soils for both the majority of sites receiving diffuse inputs from long range and regional sources and for sites in close proximity to point sources. In sediments >3,500 years and in the parent soil material of the C-horizon, (206)Pb/(207)Pb ratios are higher, 1.3 to >2.0, whereas pollution sources and surface soils and peat have lower ratios that have been in the range 1.14-1.18. (3) Using stable lead isotopes, we have estimated that in southern Sweden the cumulative anthropogenic burden of

  10. Determination of the growth of nematophagous fungi on diverse carbon sources

    Directory of Open Access Journals (Sweden)

    Martha Orozco

    2015-11-01

    Full Text Available Organic amendments have been widely used to stimulate the populations of predatory nematophagous fungi (PNF in soil; however, the use of organic amendments has produced inconsistent results in the control of parasitic nematodes. The inconsistencies have been partially attributed to the chemical composition of the organic amendments, specifically to carbon and nitrogen contents. Therefore, to know the carbon preferences of these fungi could be helpful to promote the predatory phase of the PNF in soil. The aim of this study was to determine the growth of native PNF strains from Costa Rica in diverse carbon sources. The PNF Arthrobotrys oligospora and Candelabrella musiformis were grown in artificial culture media containing the following carbon sources: cellulose, chitin, pectin, starch, and skim milk. The growth rate developed by the PNF in each one of the culture media was determined and compared. The growth rates developed by both fungal species followed the next order: cellulos e>chitin>pectin>starch>skim milk. Significant differences in the growth rates developed by the fungal strains were detected only in culture medium containing cellulose, in comparison with culture media containing other carbon sources. In culture medium containing cellulose both A. oligospora and C. musiformis grew faster with respect to the other culture media, but A. oligospora strains grew faster in comparison with C. musiformis strains. Both fungal species developed the lowest growth rates in culture media containing starch and skim milk.

  11. A lead isotopic study of the human bioaccessibility of lead in urban soils from Glasgow, Scotland

    International Nuclear Information System (INIS)

    Farmer, John G.; Broadway, Andrew; Cave, Mark R.; Wragg, Joanna; Fordyce, Fiona M.; Graham, Margaret C.; Ngwenya, Bryne T.; Bewley, Richard J.F.

    2011-01-01

    The human bioaccessibility of lead (Pb) in Pb-contaminated soils from the Glasgow area was determined by the Unified Bioaccessibility Research Group of Europe (BARGE) Method (UBM), an in vitro physiologically based extraction scheme that mimics the chemical environment of the human gastrointestinal system and contains both stomach and intestine compartments. For 27 soils ranging in total Pb concentration from 126 to 2160 mg kg -1 (median 539 mg kg -1 ), bioaccessibility as determined by the 'stomach' simulation (pH ∼ 1.5) was 46-1580 mg kg -1 , equivalent to 23-77% (mean 52%) of soil total Pb concentration. The corresponding bioaccessibility data for the 'stomach + intestine' simulation (pH ∼ 6.3) were 6-623 mg kg -1 and 2-42% (mean 22%) of soil Pb concentration. The soil 206 Pb/ 207 Pb ratios ranged from 1.057 to 1.175. Three-isotope plots of 208 Pb/ 206 Pb against 206 Pb/ 207 Pb demonstrated that 206 Pb/ 207 Pb ratios were intermediate between values for source end-member extremes of imported Australian Pb ore (1.04) - used in the manufacture of alkyl Pb compounds (1.06-1.10) formerly added to petrol - and indigenous Pb ores/coal (1.17-1.19). The 206 Pb/ 207 Pb ratios of the UBM 'stomach' extracts were similar ( 206 Pb/ 207 Pb ratio was discernible in the UBM. However, the source of Pb appeared to be less important in determining the extent of UBM-bioaccessible Pb than the overall soil total Pb concentration and the soil phases with which the Pb was associated. The significant phases identified in a subset of samples were carbonates, manganese oxides, iron-aluminium oxyhydroxides and clays. - Highlights: → We determined the human bioaccessibility of Pb in urban soils by in vitro extraction. → We determined the isotopic composition of Pb in soils and simulated stomach extracts. → Soil stable Pb isotope ratios (e.g. 206 Pb/ 207 Pb) indicated a range of sources of Pb. → 206 Pb/ 207 Pb ratios in soils and their simulated stomach extracts were very similar

  12. Geochemical partitioning of lead in biogenic carbonate sediments in a coral reef depositional environment

    International Nuclear Information System (INIS)

    Horta-Puga, Guillermo

    2017-01-01

    The fate of trace elements in reef depositional environments has not been extensively investigated. The aim of this study was to determine the partitioning of Pb in sediments of the Veracruz Reef System, and its relation to local environmental sources. Lead was determined in four geochemical fractions: exchangeable (3.8 ± 0.4 μg g −1 ), carbonate (57.0 ± 13.6 μg g −1 ), organic matter (2.0 ± 0.9 μg g −1 ), and mineral (17.5 ± 5.4 μg g −1 ). For the mineral fraction, lead concentrations were higher in those reefs influenced by river discharge or by long-distance transport of terrigenous sediments. The bioavailable concentration of lead (range: 21.9–85.6 μg g −1 ) indicates that the Veracruz Reef System is a moderately polluted area. As expected, the carbonate fraction contained the highest proportion of Pb (70%), and because the reef framework is largely made up of by biogenic carbonate sediments, hence, it is therefore the most important repository of Pb in coral reef depositional environments. - Highlights: • Lead concentrations were determined in four geochemical fractions of reef sediments. • The carbonate fraction accounted for > 70% of the content of Pb in reef sediments. • Terrigenous sediments are the main source of Pb associated to the mineral fraction. • The Veracruz Reef System is considered a moderately polluted area. • Sediments are the main repositories of lead in coral reef depositional environments.

  13. Flow injection determination of lead and cadmium in hair samples from workers exposed to welding fumes

    International Nuclear Information System (INIS)

    Cespon-Romero, R.M.; Yebra-Biurrun, M.C.

    2007-01-01

    A flow injection procedure involving continuous acid leaching for lead and cadmium determination in hair samples of persons in permanent contact with a polluted workplace environment by flame atomic absorption spectrometry is proposed. Variables such as sonication time, nature and concentration of the acid solution used as leaching solution, leaching temperature, flow-rate of the continuous manifold, leaching solution volume and hair particle size were simultaneously studied by applying a Plackett-Burman design approach. Results showed that nitric acid concentration (leaching solution), leaching temperature and sonication time were statistically significant variables (confidence interval of 95%). These last two variables were finally optimised by using a central composite design. The proposed procedure allowed the determination of cadmium and lead with limits of detection 0.1 and 1.0 μg g -1 , respectively. The accuracy of the developed procedure was evaluated by the analysis of a certified reference material (CRM 397, human hair, from the BCR). The proposed method was applied with satisfactory results to the determination of Cd and Pb in human hair samples of workers exposed to welding fumes

  14. Potential role of NADPH-oxidase in early steps of lead-induced oxidative burst in Vicia faba roots

    OpenAIRE

    Pourrut, Bertrand; Perchet, Geoffrey; Silvestre, Jérôme; Cecchi, Marie; Guiresse, Agnès Maritchù; Pinelli, Eric

    2008-01-01

    The mechanism of oxidative burst induced by lead in Vicia faba excised roots was investigated by luminol-dependent chemiluminescence. Results showed that lead triggered a rapid and dose-dependent increase in chemiluminescence production. In this study, specific inhibitors of putative reactive oxygen species (ROS) sources were used to determine the mechanism of lead-induced ROS generation. This generation was sensitive to dephenylene iodonium (DPI), quinacrine and imidazole, some inhibitors of ...

  15. Determination of trace amounts of lead by chelating ion exchange and on-line preconcentration in flow-injection atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Purohit, Rajesh; Devi, Surekha

    1992-01-01

    Resins synthesized from quinolin-8-ol and resorcinol or hydro-quinone, with furfuraldehyde, formaldehyde or benzaldehyde as cross-linking agent, were used for the preconcentration of nanogram amounts of lead. The rate of exchange and activation energy of lead exchange were calculated. Column separations of lead-copper and lead-zinc did not show any cross-contamination. A continuous flow manifold using resin microcolumns was developed for the preconcentration and determination of lead. (author). 24 refs.; 5 figs.; 3 tabs

  16. The refining of secondary lead for use in advanced lead-acid batteries

    International Nuclear Information System (INIS)

    Ellis, Timothy W.; Mirza, Abbas H.

    2010-01-01

    Secondary lead, i.e. material produced by the recycling of lead-acid batteries has become the primary source of lead in much of the world. This has been important to the secondary lead industry as other uses have dwindled, e.g. lead based pigments, chemicals, fuel additives, solders and CRT glasses. Presently, battery manufacturing accounts for greater than 80% of lead consumption while recycled lead accounts for approximately the same market share of lead supply. These two facts strongly demonstrate the battery manufacturing and recycled lead are intimately coupled in everyday life. In this paper we will explore how recycled lead has become the material of choice for battery construction through the development of a recovery and refining process that exceeds the industries requirements. Particular focus will be on addressing the results presented by Prengaman on the effects of contaminant or tramp elements on gassing in lead-acid batteries. (author)

  17. Determination of the power of multielement aerosol composition emission from distant industrial sources

    International Nuclear Information System (INIS)

    Popova, S.A.; Kutsenogij, K.P.; Chankina, O.V.

    2008-01-01

    The results from the monitoring of the temporal variability of the multielement composition of atmospheric aerosols are presented. They are used to determine the emission power of a series of elements from distant sources.

  18. Determination of lead in whole blood: Comparison of the LeadCare blood lead testing system with zeeman longitudinal electrothermal atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Pineau, A.; Viallefont, A.; Fauconneau, B.; Rafael, M.; Guillard, O.

    2002-01-01

    This study compares the efficiency of blood lead level analysis by graphite furnace atomic absorption spectrometry (GFAAS) and the portable LeadCare Blood lead testing system (LCS). Recoveries of two added lead concentrations of 22 and 42 μg/dL ranged from 102.4 to 105.5% for LCS and from 96.3 to 97.2% for GFAAS. Measurement of a certified sample (Certified Danish Whole Blood) at a blood lead concentration of 26.2 μg/dL gave within- and between-run coefficients of variation which were both approximately 8% by LCS and 2% by GFAAS. Comparison of the tested method (LCS) versus GFAAS from analysis of 76 samples of blood lead collected from workers in different industrial sectors showed imperfect overall correlation (r = 0.95). The LCS is quite suitable for screening purposes, but requires the use of non-frozen blood collected less than 24 h before. Conservative threshold values should be applied when using the LCS for initial screening in the field. (orig.)

  19. Determination of trace amount of lead in industrial and municipal effluent water samples based on dispersive liquid-liquid extraction

    International Nuclear Information System (INIS)

    Shirkhanloo, H.; Sedighi, K.; Mousavi, H. Z.

    2014-01-01

    In this study, a simple, sensitive and accurate method was developed for the determination of lead ion by combining ionic liquid dispersive liquid-liquid extraction (Il-DLL E) with flame atomic absorption spectrometry. Tetraethyl thiuram disulfide (Tetd), acetone and 1-octyl-3m ethylimidazolium hexafluorophosphate [(C 8 MIM) (PF 6 )] were used as the chelating agent, dispersive and extraction solvent, respectively. Under the optimal conditions, the calibration graph was linear in the range of 5-190 μg L -1 of lead and the detection limit was 0.8 μg L -1 with a sample volume of 200 ml. The proposed method was validated by the analysis of one certified reference material and applied successfully to the determination of lead in real water samples. (Author)

  20. Childhood lead exposure and uptake in teeth in the Cleveland area during the era of leaded gasoline

    International Nuclear Information System (INIS)

    Robbins, Norman; Zhang, Zhong-Fa; Sun, Jiayang; Ketterer, Michael E.; Lalumandier, James A.; Shulze, Richard A.

    2010-01-01

    Childhood uptake of lead from exposure to atmospheric leaded gasoline in the United States has been studied using mainly blood lead levels. Since reliable blood lead techniques were used only after the peak use of leaded gasoline, the prior exposure history is unclear. The well-documented decline in blood lead levels after the mid-1970s could represent the continuation of a historic steady decline in exposure from many sources. Alternatively, the post-1970s decline might represent the declining phase of a unimodal rise and fall corresponding closely to usage of leaded gasoline. To assess these possibilities, lead concentration and 207Pb/206Pb isotope ratios were measured in the enamel of permanent molar teeth formed between 1936 and 1993 in mainly African-American donors who grew up in the Cleveland area. Tooth enamel preserves the lead concentration and isotope ratio that prevails during tooth formation. Historical trends in enamel lead concentration were significantly correlated with surrogates of atmospheric lead exposure: lead in sediments of two dated Lake Erie cores, and lead consumed in gasoline. About two-thirds of the total lead uptake into enamel in this period was attributable to leaded gasoline, and the remainder to other sources (e.g. paint). Enamel 207Pb/206Pb isotope ratios were similar to those of one lake sediment. Multivariate analysis revealed significant correlation in neighborhoods with higher levels of traffic, and including lake sediment data, accounted for 53% of the variation in enamel lead levels. Enamel lead concentration was highly correlated with reported African-American childhood blood levels. The extrapolated peak level of 48 μg/dL (range 40 to 63) is associated with clinical and behavioral impairments, which may have implications for adults who were children during the peak gasoline lead exposure. In sum, leaded gasoline emission was the predominant source of lead exposure of African-American Cleveland children during the latter

  1. Preliminary PM2.5 and PM10 fractions source apportionment complemented by statistical accuracy determination

    Directory of Open Access Journals (Sweden)

    Samek Lucyna

    2016-03-01

    Full Text Available Samples of PM10 and PM2.5 fractions were collected between the years 2010 and 2013 at the urban area of Krakow, Poland. Numerous types of air pollution sources are present at the site; these include steel and cement industries, traffic, municipal emission sources and biomass burning. Energy dispersive X-ray fluorescence was used to determine the concentrations of the following elements: Cl, K, Ca, Ti, Mn, Fe, Ni, Cu, Zn, Br, Rb, Sr, As and Pb within the collected samples. Defining the elements as indicators, airborne particulate matter (APM source profiles were prepared by applying principal component analysis (PCA, factor analysis (FA and multiple linear regression (MLR. Four different factors identifying possible air pollution sources for both PM10 and PM2.5 fractions were attributed to municipal emissions, biomass burning, steel industry, traffic, cement and metal industry, Zn and Pb industry and secondary aerosols. The uncertainty associated with each loading was determined by a statistical simulation method that took into account the individual elemental concentrations and their corresponding uncertainties. It will be possible to identify two or more sources of air particulate matter pollution for a single factor in case it is extremely difficult to separate the sources.

  2. Lead exposures in U.S. Children, 2008: implications for prevention.

    Science.gov (United States)

    Levin, Ronnie; Brown, Mary Jean; Kashtock, Michael E; Jacobs, David E; Whelan, Elizabeth A; Rodman, Joanne; Schock, Michael R; Padilla, Alma; Sinks, Thomas

    2008-10-01

    We reviewed the sources of lead in the environments of U.S. children, contributions to children's blood lead levels, source elimination and control efforts, and existing federal authorities. Our context is the U.S. public health goal to eliminate pediatric elevated blood lead levels (EBLs) by 2010. National, state, and local exposure assessments over the past half century have identified risk factors for EBLs among U.S. children, including age, race, income, age and location of housing, parental occupation, and season. Recent national policies have greatly reduced lead exposure among U.S. children, but even very low exposure levels compromise children's later intellectual development and lifetime achievement. No threshold for these effects has been demonstrated. Although lead paint and dust may still account for up to 70% of EBLs in U.S. children, the U.S. Centers for Disease Control and Prevention estimates that >or=30% of current EBLs do not have an immediate lead paint source, and numerous studies indicate that lead exposures result from multiple sources. EBLs and even deaths have been associated with inadequately controlled sources including ethnic remedies and goods, consumer products, and food-related items such as ceramics. Lead in public drinking water and in older urban centers remain exposure sources in many areas. Achieving the 2010 goal requires maintaining current efforts, especially programs addressing lead paint, while developing interventions that prevent exposure before children are poisoned. It also requires active collaboration across all levels of government to identify and control all potential sources of lead exposure, as well as primary prevention.

  3. Maternal nutritional status during pregnancy and surma use determine cord lead levels in Karachi, Pakistan

    International Nuclear Information System (INIS)

    Janjua, Naveed Zafar; Delzell, Elizabeth; Larson, Rodney R.; Meleth, Sreelatha; Kabagambe, Edmond K.; Kristensen, Sibylle; Sathiakumar, Nalini

    2008-01-01

    Objectives: To estimate the umbilical cord blood lead levels (BLLs) of Pakistani neonates and to identify determinants for umbilical BLLs. Methods: We conducted a cross-sectional study of mothers and infants at one of the two obstetric units of two tertiary care hospitals in Karachi during January-August 2005. Information from 540 mothers selected randomly from those registered for delivery was obtained about their pregnancy, diet, and current and past lead exposures. We collected umbilical cord blood for lead levels analyzed using graphite furnace atomic absorption spectrophotometry. We computed geometric and arithmetic means. We performed multiple linear regression analysis to identify factors associated with log-transformed umbilical cord BLLs. We also performed logistic regression analysis to identify determinants of high lead cord BLLs (≥10 μg/dl). Results: The geometric mean cord BLL of the neonates was 9.6 μg/dl; arithmetic mean (S.D.) was 10.8 μg/dl (5.7) with a median of 9.7 μg/dl and a range of 1.8-48.9 μg/dl. Women who reported intake of less than 58.5 mg of elemental iron supplement per day during pregnancy had cord BLL of 10.0 μg/dl; in comparison those women who had higher iron intake had lower cord BLL (8.4 μg/dl). Those who used surma (an eye cosmetic) daily had higher cord BLL (11.5 μg/dl) as compared to those who used it less frequently (9.4 μg/dl). In multivariable linear regression model, higher iron intake, owning a car, and being in 2nd quartile of mid-arm circumference were associated with low lead levels while father's occupation in lead-based industry was associated with significantly higher umbilical cord BLLs. There was interaction of daily surma use and ethnicity. Geometric mean BLLs were varied among surma users by ethnicity. Conclusions: Umbilical cord BLLs are high in Karachi, Pakistan, in comparison to those in developed countries such as United States. Measures are needed to reduce fetal lead exposure to prevent adverse

  4. Lead in the environment

    Science.gov (United States)

    Pattee, Oliver H.; Pain, Deborah J.; Hoffman, David J.; Rattner, Barnett A.; Burton, G. Allen; Cairns, John

    2003-01-01

    Anthropogenic uses of lead have probably altered its availability and environmental distribution more than any other toxic element. Consequently, lead concentrations in many living organisms may be approaching thresholds of toxicity for the adverse effects of lead. Such thresholds are difficult to define, as they vary with the chemical and physical form of lead, exposure regime, other elements present and also vary both within and between species. The technological capability to accurately quantify low lead concentrations has increased over the last decade, and physiological and behavioral effects have been measured in wildlife with tissue lead concentrations below those previously considered safe for humans.s.236 Consequently. lead criteria for the protection of wildlife and human health are frequently under review, and 'thresholds' of lead toxicity are being reconsidered. Proposed lead criteria for the protection of natural resources have been reviewed by Eisler. Uptake of lead by plants is limited by its generally low availability in soils and sediments, and toxicity may be limited by storage mechanisms and its apparently limited translocation within most plants. Lead does not generally accumulate within the foliar parts of plants, which limits its transfer to higher trophic levels. Although lead may concentrate in plant and animal tissues, no evidence of biomagnification exists. Acid deposition onto surface waters and soils with low buffering capacity may influence the availability of lead for uptake by plants and animals, and this may merit investigation at susceptible sites. The biological significance of chronic low-level lead exposure to wildlife is sometimes difficult to quantify. Animals living in urban environments or near point sources of lead emission are inevitably subject to greater exposure to lead and enhanced risk of lead poisoning. Increasingly strict controls on lead emissions in many countries have reduced exposure to lead from some sources

  5. Determination of the maximum-depth to potential field sources by a maximum structural index method

    Science.gov (United States)

    Fedi, M.; Florio, G.

    2013-01-01

    A simple and fast determination of the limiting depth to the sources may represent a significant help to the data interpretation. To this end we explore the possibility of determining those source parameters shared by all the classes of models fitting the data. One approach is to determine the maximum depth-to-source compatible with the measured data, by using for example the well-known Bott-Smith rules. These rules involve only the knowledge of the field and its horizontal gradient maxima, and are independent from the density contrast. Thanks to the direct relationship between structural index and depth to sources we work out a simple and fast strategy to obtain the maximum depth by using the semi-automated methods, such as Euler deconvolution or depth-from-extreme-points method (DEXP). The proposed method consists in estimating the maximum depth as the one obtained for the highest allowable value of the structural index (Nmax). Nmax may be easily determined, since it depends only on the dimensionality of the problem (2D/3D) and on the nature of the analyzed field (e.g., gravity field or magnetic field). We tested our approach on synthetic models against the results obtained by the classical Bott-Smith formulas and the results are in fact very similar, confirming the validity of this method. However, while Bott-Smith formulas are restricted to the gravity field only, our method is applicable also to the magnetic field and to any derivative of the gravity and magnetic field. Our method yields a useful criterion to assess the source model based on the (∂f/∂x)max/fmax ratio. The usefulness of the method in real cases is demonstrated for a salt wall in the Mississippi basin, where the estimation of the maximum depth agrees with the seismic information.

  6. Solid phase extraction of lead on octadecyl bonded silica membrane disk modified with Cyanex302 and determination by flame atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Karve, Manjusha; Rajgor, Reeta V.

    2007-01-01

    A simple, reliable and rapid method for preconcentration and determination of lead using octadecyl bonded silica membrane disk impregnated with Cyanex302 and flame atomic absorption spectrometry is presented. The influence of aqueous phase pH, type of eluent, flow rates of sample solution and eluent, volume of eluent and amount of extractant has been investigated. The break through volume is greater than 4.0 dm 3 with an enrichment factor of more than 400 and a detection limit of 1.0 μg dm -3 . The method developed for determination of lead is good as six replicate determinations using 100 cm 3 solution containing lead in the range 1-4900 μg provides a relative standard deviation (R.S.D.) of 0.4%. The selectivity of the proposed method was confirmed from the interference studies. The developed procedure was successfully applied for the determination of lead in spiked sea water, USGS standard soil sample, sludge and industrial effluents, medicinal formulation, plant, some food products and wine

  7. Experimental determination of the neutron source for the Argonauta reactor subcritical assembly

    Energy Technology Data Exchange (ETDEWEB)

    Renke, Carlos A.C.; Furieri, Rosanne C.A.A.; Pereira, Joao C.S.; Voi, Dante L.; Barbosa, Andre L.N., E-mail: renke@ien.gov.b [Instituto de Engenharia Nuclear (IEN/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2011-07-01

    The utilization of a subcritical assembly for the determination of nuclear parameters in a multiplier medium requires a well defined neutron source to carry out the experiments necessary for the acquisition of the desired data. The Argonauta research reactor installed at the Instituto de Engenharia Nuclear has a subcritical assembly, under development, to be coupled at the upper part of the reactor core that will provide the needed neutrons emerging from its internal thermal column made of graphite. In order to perform neutronic calculations to compare with the experimental results, it is necessary a precise knowledge of the emergent neutron flux that will be used as neutron source in the subcritical assembly. In this work, we present the thermal neutron flux profile determined experimentally via the technique of neutron activation analysis, using dysprosium wires uniformly distributed at the top of the internal thermal neutron column of the Argonauta reactor and later submitted to a detection system using Geiger-Mueller detector. These experimental data were then compared with those obtained through neutronic calculation using HAMMER and CITATION codes in order to validate this calculation system and to define a correct neutron source distribution to be used in the subcritical assembly. This procedure avoids a coupled neutronic calculation of the subcritical assembly and the reactor core. It has also been determined the dimension of the graphite pedestal to be used in the bottom of the subcritical assembly tank in order to smooth the emergent neutron flux at the reactor top. Finally, it is estimated the thermal neutron flux inside the assembly tank when filled with water. (author)

  8. Evaluation of field-portable X-ray fluorescence spectrometry for the determination of lead contamination on small-arms firing ranges

    Energy Technology Data Exchange (ETDEWEB)

    Schneider, J.F.; Taylor, J.D.; Bass, D.A.; Zellmer, D. [Argonne National Lab., IL (United States); Rieck, M. [U.S. Army, Grafenwoehr Training Area (Germany)

    1995-02-01

    Field analytical methods for the characterization of lead contamination in soil are being developed. In this study, the usefulness of a commercially available, field-portable energy-dispersive X-ray fluorescence spectrometer (XRF) is evaluated for determining the extent of lead contamination in soils on small-arms firing ranges at a military installation. This field screening technique provides significant time and cost savings for the study of sites with lead-contaminated soil. Data obtained with the XRF unit in the field are compared with data obtained from soil samples analyzed in an analytical laboratory by inductively coupled plasma atomic emission spectroscopy. Results indicate that the field-portable XRF unit evaluated in this study provides data that are useful in determining the extent and relative magnitude of lead contamination. For the commercial unit used in this study, improvements in the spectral resolution and in the limit of detection would be required to make the unit more than just a screening tool.

  9. Dosimetry audit on the accuracy of 192Ir brachytherapy source strength determinations in Sweden

    Energy Technology Data Exchange (ETDEWEB)

    Carlsson Tedgren, Aasa

    2007-11-15

    The absorbed dose delivered to the patient in brachytherapy is directly proportional to the source strength in terms of the reference air-kerma rate (RAKR). Verification of this quantity by the hospitals is widely recognized as an important part of a quality assurance program. An external audit was performed on behalf of the Secondary Standard Dosimetry Laboratory at the Swedish Radiation Protection Authority (SSI). The aim was to investigate how accurately the source-strength in 192Ir brachytherapy is determined at Swedish hospitals. The SSI reference well-type ion chamber and calibrated equipment were used to measure the RAKR of an 192Ir source in each of the 14 Swedish afterloading units. Comparisons with values determined by vendors and hospitals were made. Agreement in values of RAKR as determined by SSI, hospitals and vendors were in all cases within the +-3% uncertainty (at a coverage factor of k=2), typically guaranteed by the vendors. The good agreement reflects the robustness and easy handling of well-type chambers designed for brachytherapy in use by all Swedish hospitals. The 192Ir calibration service planned at SSI will solve the hospitals current problem with recalibration of equipment. SSI can also advise hospitals to follow the IAEA recommendations for measurement techniques and maintenance of equipment. It is worthwhile for the hospitals to establish their own ratio (or deviation) with the vendor and follow it as function of time. Such a mean-ratio embeds systematic differences of various origins and have a lower uncertainty than has the RAKR alone, making it useful for early detection of problems with equipment or routines. SSI could also define requirements for the agreement between source strengths as determined by hospitals and vendors and couple this to an action plan, dependent on level of disagreement, and some kind of reporting to SSI

  10. Dosimetry audit on the accuracy of 192Ir brachytherapy source strength determinations in Sweden

    International Nuclear Information System (INIS)

    Carlsson Tedgren, Aasa

    2007-11-01

    The absorbed dose delivered to the patient in brachytherapy is directly proportional to the source strength in terms of the reference air-kerma rate (RAKR). Verification of this quantity by the hospitals is widely recognized as an important part of a quality assurance program. An external audit was performed on behalf of the Secondary Standard Dosimetry Laboratory at the Swedish Radiation Protection Authority (SSI). The aim was to investigate how accurately the source-strength in 192 Ir brachytherapy is determined at Swedish hospitals. The SSI reference well-type ion chamber and calibrated equipment were used to measure the RAKR of an 192 Ir source in each of the 14 Swedish afterloading units. Comparisons with values determined by vendors and hospitals were made. Agreement in values of RAKR as determined by SSI, hospitals and vendors were in all cases within the ±3% uncertainty (at a coverage factor of k=2), typically guaranteed by the vendors. The good agreement reflects the robustness and easy handling of well-type chambers designed for brachytherapy in use by all Swedish hospitals. The 192 Ir calibration service planned at SSI will solve the hospitals current problem with recalibration of equipment. SSI can also advise hospitals to follow the IAEA recommendations for measurement techniques and maintenance of equipment. It is worthwhile for the hospitals to establish their own ratio (or deviation) with the vendor and follow it as function of time. Such a mean-ratio embeds systematic differences of various origins and have a lower uncertainty than has the RAKR alone, making it useful for early detection of problems with equipment or routines. SSI could also define requirements for the agreement between source strengths as determined by hospitals and vendors and couple this to an action plan, dependent on level of disagreement, and some kind of reporting to SSI

  11. Determination of dosimetric characteristics of OptiSeedTM a plastic brachytherapy 103Pd source

    International Nuclear Information System (INIS)

    Wang Zhonglu; Hertel, Nolan E.

    2005-01-01

    A new 103 Pd plastic brachytherapy source, OptiSeed TM Model 1032P, is being introduced by International Brachytherapy sa (IBt). Measurements of the dose distributions about the source were performed using LiF thermoluminescent dosimeters (TLD-100) in Virtual Water TM . MCNP5 calculations were performed to determine the dose distributions in Virtual Water TM and liquid water. The source dose rate constant, radial dose function, anisotropy function and anisotropy factor have been determined following the updated AAPM TG-43 recommendations. The measured dose rate constant in the Virtual Water TM phantom was determined to be 0.727±6.9% cGy h -1 U -1 , and the computed value is 0.716±2.1% cGy h -1 U -1 . The Monte-Carlo simulation yielded a dose rate constant of 0.665±2.1% cGy h -1 U -1 in water. The measured dose rate constant in water is 0.675±7.5% cGy h -1 U -1 . It is determined by multiplying the dose rate constant measured in the Virtual Water TM phantom with the ratio of the value calculated in water to that in Virtual Water TM . The average of the measured and calculated dose rate constant is 0.670±5.5% cGy h -1 U -1 . The radial dose functions of the new source were measured for distances ranging from 1 to 7 cm in a Virtual Water TM phantom. The anisotropy functions in Virtual Water TM phantom were measured for distances of 2, 3, 5, and 7 cm. The Monte-Carlo computed radial dose functions, anisotropy functions, and anisotropy factors in both Virtual Water TM phantom and water are reported

  12. Lead (Pb) isotopic fingerprinting and its applications in lead pollution studies in China: a review.

    Science.gov (United States)

    Cheng, Hefa; Hu, Yuanan

    2010-05-01

    As the most widely scattered toxic metal in the world, the sources of lead (Pb) observed in contamination investigation are often difficult to identify. This review presents an overview of the principles, analysis, and applications of Pb isotopic fingerprinting in tracing the origins and transport pathways of Pb in the environment. It also summarizes the history and current status of lead pollution in China, and illustrates the power of Pb isotopic fingerprinting with examples of its recent applications in investigating the effectiveness of leaded gasoline phase-out on atmospheric lead pollution, and the sources of Pb found in various environmental media (plants, sediments, and aquatic organisms) in China. The limitations of Pb isotopic fingerprinting technique are discussed and a perspective on its development is also presented. Further methodological developments and more widespread instrument availability are expected to make isotopic fingerprinting one of the key tools in lead pollution investigation. Copyright 2009 Elsevier Ltd. All rights reserved.

  13. Determination of the X, Y coordinates of a pulsed ultrasonic source of signals

    International Nuclear Information System (INIS)

    Sokolov, B.V.; Shemyakin, V.V.

    1975-01-01

    A range of problems in predicting the emergency state of large-scale vessel housings are determined for subsequent solution involving acoustic emission phenomena. The authors specify the position of a given problem and present substantial grounds for selecting the minimum number of group signal receivers for unambiguous calculation of the location of the source. Relationships are obtained between X, Y - the coordinates of the pulse signal source - and experimentally measured time differences in recording of signals by group receivers. A criterion is given for selecting the true signal group combination when the receivers simultaneously record waves from several sources. Specific suggestions are made regarding the experimental information to be stored in a central computer for subsequent processing [ru

  14. Lead (Pb) isotopic fingerprinting and its applications in lead pollution studies in China: A review

    International Nuclear Information System (INIS)

    Cheng Hefa; Hu Yuanan

    2010-01-01

    As the most widely scattered toxic metal in the world, the sources of lead (Pb) observed in contamination investigation are often difficult to identify. This review presents an overview of the principles, analysis, and applications of Pb isotopic fingerprinting in tracing the origins and transport pathways of Pb in the environment. It also summarizes the history and current status of lead pollution in China, and illustrates the power of Pb isotopic fingerprinting with examples of its recent applications in investigating the effectiveness of leaded gasoline phase-out on atmospheric lead pollution, and the sources of Pb found in various environmental media (plants, sediments, and aquatic organisms) in China. The limitations of Pb isotopic fingerprinting technique are discussed and a perspective on its development is also presented. Further methodological developments and more widespread instrument availability are expected to make isotopic fingerprinting one of the key tools in lead pollution investigation. - This review presents an overview of the principles, applications, and limitations of Pb isotopic fingerprinting in lead pollution investigation, and provides a perspective on its future development.

  15. ETAAS determination of thallium and silver from water matrix after colloidal precipitate flotation using lead(II) hexamethylenedithiocarbamate

    OpenAIRE

    TRAJCE STAFILOV; KATARINA CUNDEVA; GORICA PAVLOVSKA

    2001-01-01

    Afast method for the preconcentration of thallium and silver in nanogram quantities in fresh drinking waters (source, well, tap) and waters for irrigation using colloidal precipitate flotation is described. Lead(II) hexamethylenedithiocarbamate, Pb(HMDTC)2 played the role of flotation collector. The experimental conditions for the successful separation of thallium and silver (mass of Pb, amount ofHMDTC-, pHof the system, induction time, type of surfactant etc.) were optimized. After flotation...

  16. Regional lead isotope study of a polluted river catchment: River Wear, Northern England, UK

    International Nuclear Information System (INIS)

    Shepherd, Thomas J.; Chenery, Simon R.N.; Pashley, Vanessa; Lord, Richard A.; Ander, Louise E.; Breward, Neil; Hobbs, Susan F.; Horstwood, Matthew; Klinck, Benjamin A.; Worrall, Fred

    2009-01-01

    High precision, lead isotope analyses of archived stream sediments from the River Wear catchment, northeast England (1986-88), provide evidence for three main sources of anthropogenic lead pollution; lead mining, industrial lead emissions and leaded petrol. In the upper catchment, pollution is totally controlled and dominated by large lead discharges from historic mining centres in the North Pennine Orefield ( 208 Pb/ 206 Pb, 207 Pb/ 206 Pb ratios range from 2.0744-2.0954 and 0.8413-0.8554 respectively). In the lower catchment, co-extensive with the Durham Coalfield and areas of high population density, pollution levels are lower and regionally more uniform. Isotope ratios are systematically higher than in the upper catchment ( 208 Pb/ 206 Pb, 207 Pb/ 206 Pb ratios range from 2.0856-2.1397 and 0.8554-0.8896 respectively) and far exceed values determined for the geogenic regional background. Here, the pollution is characterised by the atmospheric deposition of industrial lead and petrol lead. Lead derived from the combustion of coal, although present, is masked by the other two sources. Recent sediments from the main channel of the River Wear are isotopically indistinguishable from older, low order stream sediments of the North Pennine Orefield, indicating that contamination of the river by lead mining waste (up to several 1000 mg/kg Pb at some locations) continues to pose an environmental problem; a pattern that can be traced all the way to the tidal reach. Using within-catchment isotope variation and sediment lead concentrations, estimates can be made of the discharges from discrete mines or groups of mines to the overall level of lead pollution in the River Wear. As well as providing information pertinent to source apportionment and on-going catchment remediation measures, the database is a valuable resource for epidemiologists concerned with the health risks posed by environmental lead.

  17. The influence of time on lead toxicity and bioaccumulation determined by the OECD earthworm toxicity test

    International Nuclear Information System (INIS)

    Davies, N.A.Nicola A.; Hodson, M.E.Mark E.; Black, S.Stuart

    2003-01-01

    Timing of lead addition and worms to soil affects the response of the worms to soil affects the response of the worms to lead. - Internationally agreed standard protocols for assessing chemical toxicity of contaminants in soil to worms assume that the test soil does not need to equilibrate with the chemical to be tested prior to the addition of the test organisms and that the chemical will exert any toxic effect upon the test organism within 28 days. Three experiments were carried out to investigate these assumptions. The first experiment was a standard toxicity test where lead nitrate was added to a soil in solution to give a range of concentrations. The mortality of the worms and the concentration of lead in the survivors were determined. The LC 50 s for 14 and 28 days were 5311 and 5395 μg Pb g -1 soil respectively. The second experiment was a timed lead accumulation study with worms cultivated in soil containing either 3000 or 5000 μg Pb g -1 soil . The concentration of lead in the worms was determined at various sampling times. Uptake at both concentrations was linear with time. Worms in the 5000 μg g -1 soil accumulated lead at a faster rate (3.16 μg Pb g -1 tissue day -1 ) than those in the 3000 μg g -1 soil (2.21 μg Pb g -1 tissue day -1 ). The third experiment was a timed experiment with worms cultivated in soil containing 7000 μg Pb g -1 soil . Soil and lead nitrate solution were mixed and stored at 20 deg. C. Worms were added at various times over a 35-day period. The time to death increased from 23 h, when worms were added directly after the lead was added to the soil, to 67 h when worms were added after the soil had equilibrated with the lead for 35 days. In artificially Pb-amended soils the worms accumulate Pb over the duration of their exposure to the Pb. Thus time limited toxicity tests may be terminated before worm body load has reached a toxic level. This could result in under-estimates of the toxicity of Pb to worms. As the equilibration

  18. Lead isotopes in mantle derived xenoliths from Japan and South Africa

    International Nuclear Information System (INIS)

    Morioka, Masana; Kigoshi, Kunihiko.

    1978-01-01

    The lead isotopic compositions and the uranium, thorium and lead contents of eclogite and harzburgite inclusions from South African Kimberlite-pipes and lherzolite inclusions from Itinomegata crater, Japan and of their main mineral fractions have been determined. The observed 206 Pb/ 204 Pb, 207 Pb/ 204 Pb and 238 U/ 204 Pb in lherzolite samples from Itinomegata range from 17.9 to 18.2, from 15.1 to 15.5 and from 1.9 to 23, respectively. The results suggest that the lherzolites were of recent crystallization. The observed data on eclogite inclusions show no consistent pattern and suggest that they have a complicated history. The observed lead isotopic compositions of harzburgite inclusions from kimberlite-pipes are 206 Pb/ 204 Pb = 17.3 -- 19.0 and 207 Pb/ 204 Pb = 15.3 -- 15.6. These results are distributed in a wide range on two regression lines, suggesting that they had been formed from the same source material but with different ages or have been formed recently by mixing of two different source materials and host rock of kimberlite. (author)

  19. Quantitative determination of iron, copper, lead, chromium and nickel in electronic waste samples using total reflection x-ray fluorescence spectroscopy

    International Nuclear Information System (INIS)

    Elaseer, A. S.; Musbah, A. S; Ammar, M. M. G.; Salah, M. A.; Aisha, E. A.

    2015-01-01

    Total reflection x-ray fluorescence spectroscopy in conjunction with microwave assisted extraction technique was used for the analysis of twenty electronic waste samples. The analysis was limited to the printed circuit boards of electronic devices. Iron, copper, lead, chromium and nickel were quantitatively determined in the samples. The samples were carefully milled to fine powder and 50mg was digested by acid using microwave digestion procedure. The digested samples solution was spread together with gallium as internal standard on the reflection disk and analyzed. The results showed that the cassette recorder boards contain the highest concentration of iron, lead and nickel. The average concentrations of these metals were 78, 73 and 71g/Kg respectively. Computer boards contained the highest copper average concentration 39g/Kg. the highest chromium average concentration 3.6 g/Kg was in mobile phone boards. Measurements were made using PicoTAX portable x-ray device. the instrument was used for quantitative multi-element analysis. An air cooled x-ray tube (40KV, 1 mA) with Mo target and Be window was used as x-ray source. The optics of the device was a multilayer Ni/C, 17.5 keV, 80% reflectivity provides analysis of elements from Si to Zr (K series) and Rh to U (L series). A Si PIN-diode detector (7mm"2, 195eV) was used for the elements detection. In this study heavy metals average concentration in electronic circuit boards in the in the order of iron (35.25g/kg), copper (21.14g/Kg), lead (16.59g/Kg), nickel (16.01g/Kg) and chromium (1.07g/Kg).(author)

  20. The effect of different propolis harvest methods on its lead contents determined by ET AAS and UV-visS

    Energy Technology Data Exchange (ETDEWEB)

    Sales, A. [Department of Analytical Chemistry, Faculty of Biochemistry, Chemistry and Pharmacy, National University of Tucuman, Ayacucho 471, 4000 Tucuman (Argentina)]. E-mail: amsales@fbqf.unt.edu.ar; Alvarez, A. [National Institute of Agricultural Technology (INTA), Experimental Station Famailla, Ruta 301, Km 32, Famailla, Tucuman (Argentina); Areal, M. Rodriguez [Department of Analytical Chemistry, Faculty of Biochemistry, Chemistry and Pharmacy, National University of Tucuman, Ayacucho 471, 4000 Tucuman (Argentina); Maldonado, L. [National Institute of Agricultural Technology (INTA), Experimental Station Famailla, Ruta 301, Km 32, Famailla, Tucuman (Argentina); Marchisio, P. [Department of Analytical Chemistry, Faculty of Biochemistry, Chemistry and Pharmacy, National University of Tucuman, Ayacucho 471, 4000 Tucuman (Argentina); Rodriguez, M. [Department of Analytical Chemistry, Faculty of Biochemistry, Chemistry and Pharmacy, National University of Tucuman, Ayacucho 471, 4000 Tucuman (Argentina); Bedascarrasbure, E. [National Institute of Agricultural Technology (INTA), Experimental Station Famailla, Ruta 301, Km 32, Famailla, Tucuman (Argentina)

    2006-10-11

    Argentinean propolis is exported to different countries, specially Japan. The market demands propolis quality control according to international standards. The analytical determination of some metals, as lead in food, is very important for their high toxicity even in low concentrations and because of their harmful effects on health. Flavonoids, the main bioactive compounds of propolis, tend to chelate metals as lead, which becomes one of the main polluting agents of propolis. The lead found in propolis may come from the atmosphere or it may be incorporated in the harvest, extraction and processing methods. The aim of this work is to evaluate lead level on Argentinean propolis determined by electrothermal atomic absorption spectrometry (ET AAS) and UV-vis spectrophotometry (UV-visS) methods, as well as the effect of harvest methods on those contents. A randomized test with three different treatments of collection was made to evaluate the effect of harvest methods. These procedures were: separating wedges (traditional), netting plastic meshes and stamping out plastic meshes. By means of the analysis of variance technique for multiple comparisons (ANOVA) it was possible to conclude that there are significant differences between scraped and mesh methods (stamped out and mosquito netting meshes). The results obtained in the present test would allow us to conclude that mesh methods are more advisable than scraped ones in order to obtain innocuous and safe propolis with minor lead contents. A statistical comparison of lead determination by both, ET AAS and UV-visS methods, demonstrated that there is not a significant difference in the results achieved with the two analytical techniques employed.

  1. Determination of trace amount of lead in industrial and municipal effluent water samples based on dispersive liquid-liquid extraction

    Energy Technology Data Exchange (ETDEWEB)

    Shirkhanloo, H. [Iranian Petroleum Industry Health Research Institute, Occupational and Environmental Health Research Center, Tehran (Iran, Islamic Republic of); Sedighi, K.; Mousavi, H. Z., E-mail: hzmousavi@semnan.ac.ir [Semnan University, College of Science, Department of Chemistry, Semnan (Iran, Islamic Republic of)

    2014-10-01

    In this study, a simple, sensitive and accurate method was developed for the determination of lead ion by combining ionic liquid dispersive liquid-liquid extraction (Il-DLL E) with flame atomic absorption spectrometry. Tetraethyl thiuram disulfide (Tetd), acetone and 1-octyl-3m ethylimidazolium hexafluorophosphate [(C{sub 8}MIM) (PF{sub 6})] were used as the chelating agent, dispersive and extraction solvent, respectively. Under the optimal conditions, the calibration graph was linear in the range of 5-190 μg L{sup -1} of lead and the detection limit was 0.8 μg L{sup -1} with a sample volume of 200 ml. The proposed method was validated by the analysis of one certified reference material and applied successfully to the determination of lead in real water samples. (Author)

  2. Lead Poisoning Prevention Tips

    Science.gov (United States)

    ... or removed safely. How are children exposed to lead? Lead-based paint and lead contaminated dust are ... What can be done to prevent exposure to lead? It is important to determine the construction year ...

  3. Dependence of proton beam polarization on ion source transition configurations; Determination de la polarisation du faisceau de protons pour les quatre configurations des transitions de la source d`ions

    Energy Technology Data Exchange (ETDEWEB)

    Arvieux, J.; Ausset, P.; Ball, J.; Beauvais, P.Y.; Bedfer, Y.; Chamouard, P.A.; Fontaine, J.M.; Kunne, R.; Lagniel, J.M.; Sans, J.L. [Laboratoire National Saturne - Centre d`Etudes Nucleaires de Saclay, 91 - Gif-sur-Yvette (France); Allgower, Ch.; Kasprzyk, T.E.; Spinka, H.M. [ANL-HEP, Argonne (United States); Bystricky, J.; Lehar, F.; Lesquen, A. de [CEA Centre d`Etudes de Saclay, 91 - Gif-sur-Yvette (France). Dept. d`Astrophysique, de la Physique des Particules, de la Physique Nucleaire et de l`Instrumentation Associee; Demiere, Ph.; Rapin, D.; Teglia, A. [Geneva Univ. (Switzerland). Dept. de Physique Nucleaire et Corpusculaire; Janout, Z. [Czech Technical Univ., Prague (Czech Republic). Faculty of Civil Engineering; Kalinnikov, V.A.; Khachaturov, B.A.; Popov, A.A. [Laboratory of Nuclear Problems, JINR, Moscow (Russian Federation); Prokofiev, A.N.; Vikhrov, V.V.; Zhdanov, A.A. [Nuclear Physics Inst., St. Petersburg (Russian Federation)

    1997-12-31

    Considerable anomalies were observed in recorded pp elastic scattering spin dependent data at several proton beam energies at SATURNE II. These results suggested that the discrepancies are related to the polarized ion source. In order to understand the observed effects, the proton beam polarizations for each ion source state were determined separately. Convenient procedures, allowing to determine the beam polarization from a beam-line polarimeter are presented. Two distinct experiments are necessary for this purpose. In the first one the LEFT-RIGHT instrumental asymmetry of the beam polarimeter arms is determined. In the second one this correction factor is applied to asymmetries measured with the beam from the polarized ion source in different polarization states. Both experiments determined the scattering asymmetries for all four polarized source states as functions of different source parameters. The measurements were carried out at the proton beam kinetic energy 0.80 GeV, where the pp elastic scattering analyzing power is at its maximum. Results show that the so called `unpolarized states` of the source are polarized, whereas the absolute values of the beam polarizations in `polarized states` are equal. It was observed that the hexapole lens of the ion source provides some beam polarization in the absence of any transition. The beam polarization as function of the hexapole current, of the transition efficiencies and of the rotation solenoid current has been studied. It is also shown, how one way obtain a strictly unpolarized beam using the polarized source only. The results obtained with the SATURNE II ion source HYPERION may be also valid for other accelerators and sources. (authors) 10 refs.

  4. Open-Source Low-Cost Wireless Potentiometric Instrument for pH Determination Experiments

    Science.gov (United States)

    Jin, Hao; Qin, Yiheng; Pan, Si; Alam, Arif U.; Dong, Shurong; Ghosh, Raja; Deen, M. Jamal

    2018-01-01

    pH determination is an essential experiment in many chemistry laboratories. It requires a potentiometric instrument with extremely low input bias current to accurately measure the voltage between a pH sensing electrode and a reference electrode. In this technology report, we propose an open-source potentiometric instrument for pH determination…

  5. [Isolation, identification and lead adsorption study of lead-resistant Lactobacillus casei strains from feces of healthy newborns].

    Science.gov (United States)

    Shen, Wei; Yu, Qin-Fei; Wang, Yu-Hao; Zhang, Yi-Duo; Meng, Xiao-Jing; Fan, Hong-Ying

    2016-12-20

    To isolate and identify lead-resistant Lactobacillus casei strains with lead adsorption ability from the stool of healthy newborns as a new source of bacteria for developing lead-eliminating food products. MRS was used to isolate lead-resistant bacteria from the feces of 30 healthy and full-term neonates. A phylogenetic tree was constructed based on the morphological characteristics and 16S rRNA sequences of the isolated bacteria. Physiological and biochemical characterizations of the bacteria were performed according to the Berger's Systematic Bacteriology Handbook, followed by antimicrobial susceptibility test and acid-tolerant bile salt test. The adsorption capacity of Pb 2+ of the bacteria was determined by inductively coupled plasma-optical emission spectroscopy (ICP-OES). Three strains of Lactobacillus casei were isolated, which were resistant to penicillin and ceftriaxone and could tolerate the exposure to 500 mg/L Pb 2+ . Acid-tolerant bile salt test showed that the bacteria were resistant to culture in the presence of artificial gastric juice (pH 2.0) for 3 h, and their survival rate reached 62.5% following exposure to 0.3% bile salt for 8 h. The bacteria showed a Pb 2+ adsorption rate of 90.4% at a low Pb 2+ concentration (1 mg/L) and of 86.27% at a high Pb 2+ concentration (50 mg/L). Three Lactobacillus casei strains lead adsorption ability were isolated from the feces of newborns. These bacterial strains provide a new solution to alleviate lead poisoning by probiotic dietary.

  6. Non-destructive γ-spectrometric determination of mercury and gold in sea water after preconcentration by lead sulphide

    International Nuclear Information System (INIS)

    Alexandrov, S.

    1976-01-01

    A method is described for determination of mercury and gold in sea-water, based on preconcentration of these elements by retention on a column of lead sulphide at pH1 (nitric and sulphuric acids), and γ-spectrometry. Mercury (0.8 +-0.2 μg/l) and gold (6 +- 3 ng/l) have been determined in a sample from the Black Sea, taken near Varna. (author)

  7. Determination of optimal geometry for cylindrical sources for gamma radiation measurements; Odredjivanje optimalne geometrije za mjerenje gama zracenja cilindrichnih izvora

    Energy Technology Data Exchange (ETDEWEB)

    Sinjeri, Lj; Kulisic, P [Elektra - Zagreb, Zagreb (Yugoslavia)

    1990-07-01

    Low radioactive sources were used for experimental determination of optimal dimensions for cylindrical source using coaxial Ge(Li) detector. Then, calculational procedure is used to find optimal dimensions of cylindrical source. The results from calculational procedure confirm with experimental results. In such way the verification of calculational procedure is done and it can be used for determination of optimal geometry for low radioactive cylindrical sources. (author)

  8. Standard test method for graphite furnace atomic absorption spectrometric determination of lead and cadmium extracted from ceramic foodware

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2000-01-01

    1.1 This test method covers procedures for using graphite furnace atomic absorption spectroscopy (GFAAS) to quantitatively determine lead and cadmium extracted by acetic acid at room temperature from the food-contact surface of foodware. The method is applicable to food-contact surfaces composed of silicate-based materials (earthenware, glazed ceramicware, decorated ceramicware, decorated glass, and lead crystal glass) and is capable of determining lead concentrations greater than 0.005 to 0.020 g/mL and cadmium concentrations greater than 0.0005 to 0.002 g/mL, depending on instrument design. 1.2 This test method also describes quality control procedures to check for contamination and matrix interference during GFAAS analyses and a specific sequence of analytical measurements that demonstrates proper instrument operation during the time period in which sample solutions are analyzed. 1.3 Cleaning and other contamination control procedures are described in this test method. Users may modify contamination cont...

  9. ANL calculational methodologies for determining spent nuclear fuel source term

    International Nuclear Information System (INIS)

    McKnight, R. D.

    2000-01-01

    Over the last decade Argonne National Laboratory has developed reactor depletion methods and models to determine radionuclide inventories of irradiated EBR-II fuels. Predicted masses based on these calculational methodologies have been validated using available data from destructive measurements--first from measurements of lead EBR-II experimental test assemblies and later using data obtained from processing irradiated EBR-II fuel assemblies in the Fuel Conditioning Facility. Details of these generic methodologies are described herein. Validation results demonstrate these methods meet the FCF operations and material control and accountancy requirements

  10. A simple method for determining the activity of large-area beta sources constructed from anodized aluminum foils

    International Nuclear Information System (INIS)

    Stanga, D.

    2014-01-01

    A simple method has been developed for determining the activity of large-area beta reference sources in anodized aluminum foils. It is based on the modeling of the transmission of beta rays through thin foils in planar geometry using Monte Carlo simulation. The method was checked experimentally and measurement results show that the activity of large-area beta reference sources in anodized aluminum foils can be measured with standard uncertainties smaller than the limit of 10% required by ISO 8769. - Highlights: • A method for determining the activity of large-area beta sources is presented. • The method is based on a model of electron transport in planar geometry. • The method makes use of linear programming for determining the activity. • The uncertainty of the method is smaller than 10%

  11. High human exposure to lead through consumption of birds hunted with lead shot

    International Nuclear Information System (INIS)

    Johansen, P.; Asmund, G.; Riget, F.

    2004-01-01

    Lead shot contaminates the edible parts of birds so that tolerable human lead intake is exceeded. - We assess lead contamination of Greenland seabirds killed with lead shot having studied thick-billed murre and common eider, the two most important species in the diet. The lead concentration is very high in meat of eiders killed with lead shot (mean 6.1 μg/g-wet wt, 95% CL 2.1-12). This level is about 44 times higher than in drowned eiders and eight times higher than in shot murres. Analyzing whole breasts instead of sub-samples reveals about seven times higher lead levels in birds' meat. We conclude that in some cases the lead intake by Greenland bird eaters will largely exceed the FAO/WHO tolerable lead intake guideline and that lead shot is a more important source of lead in the diet than previously estimated

  12. Transport of lead to crack tips in steam generator tubes

    International Nuclear Information System (INIS)

    Adler, G.D.; Marks, C.R.; Fruzzetti, K.

    2009-01-01

    The mechanisms by which lead is transported from its ultimate source to steam generator tubes and into cracks are not well understood and, to date, a comprehensive evaluation of possible mechanisms has not previously been performed. Specifically, local lead concentrations up to 20 wt. percent have been measured at crack tips, and it is not fully understood how lead concentrations of this magnitude occur, since lead concentrations in SG feedwater are typically quite low (on the order of a few parts per trillion). Additionally, there is evidence that at secondary side conditions, lead is essentially entirely adsorbed onto solid surfaces. Furthermore, if lead were present in the liquid phase, it would not be expected to be in a form that would facilitate concentration in a crevice (crack) by electrochemical means. There has previously been some speculation that lead transport to crack tips may occur through surface diffusion of adsorbed species. It has also been postulated that lead transport may occur via diffusion through the oxide layer along crack walls or via diffusion of lead out of the bulk Alloy 600 to grain boundaries exposed to secondary water by advancing cracks. However, there have been no critical evaluations of these hypotheses. With the current state of knowledge, it is difficult for utilities to determine whether additional efforts to further reduce the inventory of lead in the secondary system are justified. Furthermore, specific sources of lead that are especially likely to accelerate SCC cannot be identified (e.g., significant masses of lead are present in SG deposits, but it is not known if this lead can be transported to crack tips). The work presented in this paper quantitatively evaluates (based on the published literature, not new experimental work) a number of hypothesized lead transport mechanisms, including: Liquid phase diffusion; Electrochemically influenced diffusion of cations and anions; Bulk alloy diffusion; Surface diffusion; Solid

  13. Long-term human exposure to lead from different media and intake pathways.

    Science.gov (United States)

    Pizzol, Massimo; Thomsen, Marianne; Andersen, Mikael Skou

    2010-10-15

    Lead (Pb) is well known as an environmental pollutant: it can accumulate in various media, so actual lead exposure reflects both historical and present contaminations. Two main challenges then emerge: obtaining updated information to gain an overall picture of the sources of exposure, and predicting the resulting internal body exposure levels and effects that occur under long-term exposure conditions. In this paper, a modeling approach is used to meet these challenges with reference to Danish exposure conditions. Levels of lead content in various media have been coupled with data for lead intake and absorption in the human body, for both children and adults. An age-dependent biokinetic model allows then for determination of the blood lead levels resulting from chronic exposure. The study shows that the actual intake of lead is up to 27% of the Provisional Tolerable Daily Intake (PTDI) for children and around 8% for adults. It is confirmed that the critical route of exposure is via ingestion, accounting for 99% of total lead intake, while inhalation contributes only to 1% of total lead intake. The resulting lead levels in the blood after 2 years of exposure to actual contamination conditions have been estimated as up to 2.2μg/dl in children and almost 1μg/dl in adults. Impacts from lead can occur even at such levels. The role of historical and present sources to lead in the environment is discussed, and, for specific child and adult exposure scenarios, external-internal concentration relationships for the direct linkage between lead in environmental media and resulting concentrations of lead in blood are then presented. Copyright © 2010 Elsevier B.V. All rights reserved.

  14. Anthropogenic lead concentrations and sources in Baltic Sea sediments based on lead isotopic composition

    International Nuclear Information System (INIS)

    Zaborska, Agata

    2014-01-01

    Highlights: • Pb concentrations reach even 147 μg/g at Gdansk Basin sediments. • Marine sediments deposited before 1860 are not contaminated by Pb. • Contemporary inventories of anthropogenic Pb in marine sediments was of 0.5–11 g for m 2 . • The lowest 206 Pb/ 207 Pb (1.165) were measured in sediments deposited between 1970s–90s. • Coal burning was always the most important Pb source in Poland. - Abstract: The Gulf of Gdańsk is influenced by heavy metals of anthropogenic origin. In this study, temporal concentration changes of Pb, Zn, Cd, and Cu were studied in six, 50 cm long sediment cores. The main aim of the study was to concentrate on the history of Pb fluxes and Pb isotopic composition ( 206 Pb/ 207 Pb and 208 Pb/ 206 Pb) to trace Pb sources. The lowest Pb concentrations (19 μg g −1 ) were measured in sediments deposited circa 1860, while the highest Pb concentrations (63–147 μg g −1 ) were measured in sediments deposited between 1960s and 70s. Pre-industrial Pb fluxes were 7 Pb m 2 year −1 , while after WWII they reached 199 Pb m 2 year −1 . Highest 206 Pb/ 207 Pb ratios (∼1.22) were measured in the oldest sediment layers, and the lowest 206 Pb/ 207 Pb ratios (∼1.165) were measured in the sediments deposited in 1970s–90s. During the period of highest Pb contamination, the anthropogenic Pb fraction reached up to 93%. A general discussion of the Pb sources, emissions, and loads for Poland is included

  15. The potential of elemental and isotopic analysis of tree bark for discriminating sources of airborne lead contamination in the UK.

    Science.gov (United States)

    Bellis, D; McLeod, C W; Satake, K

    2001-02-01

    Samples of tree bark, which accumulate airborne material, were collected from seven locations in the UK to provide an indication of the magnitude and source of lead pollution. Measurement of the Pb content and 206/207Pb stable isotope ratio by inductively coupled plasma mass spectrometry revealed significant differences between the sites. The concentration of Pb varied over almost four orders of magnitude from 7.2 to 9,600 micrograms g-1, the maximum values being found near a 'secondary' Pb smelter. The 206/207Pb isotope ratios varied from 1.108 +/- 0.002 to 1.169 +/- 0.001. The lowest Pb concentrations and highest isotope ratios were detected in bark samples from the Scilly Isles, reflecting the low-level of industry and road traffic. In contrast, samples obtained from a city centre (Sheffield) and near a motorway (M1) contained 25-46 micrograms g-1 Pb and recorded the lowest 206/207Pb ratios. Higher concentrations in the vicinity of a coal-fired power station recorded a 206/207Pb ratio of 1.14, suggesting a significant contribution from fly-ash. The relative contribution of lead from petrol (206/207Pb = 1.08) and other sources such as coal (206/207Pb = 1.18) were thus estimated using mass balance equations. Tree bark near the lead smelter recorded an intermediate 206/207Pb ratio of 1.13 reflecting the processing of material of mixed origin.

  16. An analytical study of prehistoric lead and silver objects from the Aegean

    International Nuclear Information System (INIS)

    Pernicka, E.; Wagner, G.A.; Assimenos, K.; Doumas, C.; Begemann, F.; Todt, W.

    1983-01-01

    In the course of an archaeometallurgical study on the metal sources of archaic silver coinage it was discovered that lead-silver mines on the Cycladic island of Siphnos, which were known to Herodotus (III, 57) and exploited in archaic times, were already worked in the Early Bronze Age (EBA). In addition, new excavations in Thorikos have shown that the well-known lead-silver deposit of Laurion on Attika was also exploited as early as the EBA. In order to assess the role which these two mining districts and other possible ore sources played in the Bronze Age for the supply of lead and silver, we analyzed prehistoric lead and silver objects from the Aegean region. The methods employed were the same as have been used to characterize the ore deposits. In addition we wanted to study to what extent cupellation was practised in these early periods. Bulk composition and trace element concentrations were determined by instrumental and radiochemical neutron activation and atomic absorption spectrometry. Isotope abundance analyses were performed on a VARIAN MAT 261 mass spectrometer. Experimental details are given. Results are presented and discussed. (U.K.)

  17. A photon spectrometric dose-rate constant determination for the Advantage™ Pd-103 brachytherapy source

    OpenAIRE

    Chen, Zhe Jay; Bongiorni, Paul; Nath, Ravinder

    2010-01-01

    Purpose: Although several dosimetric characterizations using Monte Carlo simulation and thermoluminescent dosimetry (TLD) have been reported for the new Advantage™ Pd-103 source (IsoAid, LLC, Port Richey, FL), no AAPM consensus value has been established for the dosimetric parameters of the source. The aim of this work was to perform an additional dose-rate constant (Λ) determination using a recently established photon spectrometry technique (PST) that is independent of the published TLD and ...

  18. Effect measure modification of blood lead-air lead slope factors.

    Science.gov (United States)

    Richmond-Bryant, Jennifer; Meng, Qingyu; Cohen, Jonathan; Davis, J Allen; Svendsgaard, David; Brown, James S; Tuttle, Lauren; Hubbard, Heidi; Rice, Joann; Kirrane, Ellen; Vinikoor-Imler, Lisa; Kotchmar, Dennis; Hines, Erin; Ross, Mary

    2015-01-01

    There is abundant literature finding that susceptibility factors, including race and ethnicity, age, and housing, directly influence blood lead levels. No study has explored how susceptibility factors influence the blood lead-air lead relationship nationally. The objective is to evaluate whether susceptibility factors act as effect measure modifiers on the blood lead-air lead relationship. Participant level blood lead data from the 1999 to 2008 National Health and Nutrition Examination Survey were merged with air lead data from the US Environmental Protection Agency. Linear mixed effects models were run with and without an air lead interaction term for age group, sex, housing age, or race/ethnicity to determine whether these factors are effect measure modifiers for all ages combined and for five age brackets. Age group and race/ethnicity were determined to be effect measure modifiers in the all-age model and for some age groups. Being a child (1-5, 6-11, and 12-19 years) or of Mexican-American ethnicity increased the effect estimate. Living in older housing (built before 1950) decreased the effect estimate for all models except for the 1-5-year group, where older housing was an effect measure modifier. These results are consistent with the peer-reviewed literature of time-activity patterns, ventilation, and toxicokinetics.

  19. Characterization of a 137Cs standard source for calibration purposes at CRCN-NE

    International Nuclear Information System (INIS)

    Oliveira, Mercia L.; Santos, Marcus A.P. dos; Benvides, Clayton A.

    2008-01-01

    Radiation protection monitoring instruments should be calibrated by accredited calibration laboratories. To offer calibration services, a laboratory must accomplish all requirements established by the national regulatory agency. The Calibration Service of the Centro Regional de Ciencias Nucleares (CRCN-NE), Comissao Nacional de Energia Nuclear, Recife, Brazil, is trying to achieve this accreditation. In the present work, a 137 Cs standard source was characterized following the national and international recommendations and the results are presented. This source is a commercially available single source irradiator model 28-8A, manufactured by J.L. Shepherd and Associates, with initial activity of 444 GBq (05/13/03). To provide different air kerma rates, as required for the calibration of portable radiation monitors, this irradiator have a set of four lead attenuators with different thickness, providing attenuation factors equal to 2, 4, 10 and 100 times (nominally). The performed tests included: size and uniformity of the radiation standard field at calibration reference position, variation of the air kerma rate for different lead attenuators, determination of attenuation factors for each lead attenuator configuration, and determination of the radiation scattering at the calibration reference position. The results showed the usefulness of the 137 Cs standard source for the calibration of radiation protection monitoring detectors. (author)

  20. Stable lead isotopes as a tracer in coastal waters

    International Nuclear Information System (INIS)

    Stukas, V.J.; Wong, C.S.

    1981-01-01

    The natural abundances of the stable isotopes of lead are used to identify natural and industrial sources of lead in the coastal waters of British Columbia, Canada. The 206 Pb/ 207 Pb ratios, used to characterize the lead source, had values of approx. 1.24 for coastal oceanic water, approx. 1.22 for fjord waters receiving lead from mine tailings, and approx. 1.163 for waters near urban centers. The lead concentration data are in agreement with presently accepted seawater values

  1. Determining the temperature and density distribution from a Z-pinch radiation source

    International Nuclear Information System (INIS)

    Matuska, W.; Lee, H.

    1997-01-01

    High temperature radiation sources exceeding one hundred eV can be produced via z-pinches using currently available pulsed power. The usual approach to compare the z-pinch simulation and experimental data is to convert the radiation output at the source, whose temperature and density distributions are computed from the 2-D MHD code, into simulated data such as a spectrometer reading. This conversion process involves a radiation transfer calculation through the axially symmetric source, assuming local thermodynamic equilibrium (LTE), and folding the radiation that reaches the detector with the frequency-dependent response function. In this paper the authors propose a different approach by which they can determine the temperature and density distributions of the radiation source directly from the spatially resolved spectral data. This unfolding process is reliable and unambiguous for the ideal case where LTE holds and the source is axially symmetric. In reality, imperfect LTE and axial symmetry will introduce inaccuracies into the unfolded distributions. The authors use a parameter optimization routine to find the temperature and density distributions that best fit the data. They know from their past experience that the radiation source resulting from the implosion of a thin foil does not exhibit good axial symmetry. However, recent experiments carried out at Sandia National Laboratory using multiple wire arrays were very promising to achieve reasonably good symmetry. For these experiments the method will provide a valuable diagnostic tool

  2. Methods for the determination of lunisolar precession from observations of extragalactic radio sources

    International Nuclear Information System (INIS)

    Elsmore, B.

    1976-01-01

    Although it is not practicable at present to determine the position or motion of the equinox using radio techniques, lunisolar precession may be determined from measurements at two epochs of differences of (i) Right Ascension -RA, and (ii) Declinations - Dec., of extragalactic radio sources. The determinations are largely free from systematic errors, and the magnitudes of random errors, arising principally from tropospheric irregularities, are given for observations with the Cambridge 5-km telescope. Some first epoch measure-ments have been made with this instrument and it is estimated that by carrying out second epoch measurements after an interval of 5 yr, the centennial value of lunisolar precession will be determined with a standard error of +- 0''.25. (author)

  3. Determination of lead, zinc and benzo(a)pyrene in incineration flue gas

    International Nuclear Information System (INIS)

    Han Baohua; Gao Zhuqin; Guo Qian

    2003-01-01

    An analitical method was developed for the determination of lead(Pb), zinc(Zn) and benzo(a)pyrene (BaP) in flue gas of radwaste pyroysis incinerator, respectively using Inductively Coupled Plasma-Atomic Emission Spectrometry (ICP-AES) and High Performance Liquid Chromatography (HPLC). The sample preparation and the influence of major components in back-ground were researched. Interference correction coefficient for Pb and Zn are given in this article. The recovery of Pb, Zn and BaP are all above 84.0% and the relative standard deviation (RSD) were 3.51% for Pb, 7.28% for Zn and 4.50% for BaP, respectively. It shows that this analytical method can meet the incineration processes. (authors)

  4. Determination of air kerma standard of high dose rate 192Ir brachytherapy source

    International Nuclear Information System (INIS)

    Pires, E.J.; Alves, C.F.E.; Leite, S.P.; Magalhaes, L.A.G.; David, M.G.; Almeida, C.E. de

    2015-01-01

    This paper presents the methodology developed by the Laboratorio de Ciencias Radiologicas and presently in use for determining of the air kerma standard of 192 Ir high dose rate sources to calibrate well-type chambers. Uncertainty analysis involving the measurements procedure are presented. (author)

  5. Bone lead levels and lead isotope ratios in red grouse from Scottish and Yorkshire moors

    Energy Technology Data Exchange (ETDEWEB)

    Thomas, Vernon G., E-mail: vthomas@uoguelph.ca [Department of Integrative Biology, College of Biological Science, University of Guelph, Guelph, Ontario, N1G 2W1 (Canada); Scheuhammer, Anton M.; Bond, Della E. [Metals Toxicology Laboratory, National Wildlife Research Centre, Carleton University, Ottawa, Ontario, K1A 0H3 (Canada)

    2009-05-15

    Leg and foot bones of adult and juvenile red grouse (Lagopus lagopus scoticus) were collected from hunter-shot birds on two Scottish estates (Glendye and Invermark) and one Yorkshire estate in September, 2003. The lead content of bones was measured by atomic absorption spectrophotometry, and corresponding stable lead isotopes (Pb204, 206, 207, 208) by inductively coupled plasma mass spectrometry. At the Glendye (N = 111) and Invermark (N = 85) estates, relatively few birds (5.4% and 3.5%, respectively) had highly elevated bone lead concentrations (> 20 mug/g dry weight). In bones of these highly exposed birds, a combination of Pb206:Pb207 and Pb208:Pb207ratios was consistent with ingestion of lead gunshot available in Europe. By contrast, Yorkshire grouse experienced a high incidence (65.8%) of bone lead > 20 mug/g. The Pb206:Pb207 and Pb208:Pb207ratios in bones of these highly exposed birds were consistent with a combined exposure to ingested lead gunshot and lead from galena mining in the region. Lead isotope ratios also indicated that lead from UK gasoline combustion and fallout from atmospheric particles was not a likely source of elevated lead in bones of either Scottish or Yorkshire grouse. Suggested management options for the three moors include adopting nontoxic shot for all game shooting on the estates, allowing heather (Calluna vulgaris) vegetation to grow tall in lead shot fall-out zones to reduce physical access to high densities of lead shot already present, and provision of calcareous grit across moors to reduce lead assimilation from all ingested sources of lead.

  6. Bone lead levels and lead isotope ratios in red grouse from Scottish and Yorkshire moors

    International Nuclear Information System (INIS)

    Thomas, Vernon G.; Scheuhammer, Anton M.; Bond, Della E.

    2009-01-01

    Leg and foot bones of adult and juvenile red grouse (Lagopus lagopus scoticus) were collected from hunter-shot birds on two Scottish estates (Glendye and Invermark) and one Yorkshire estate in September, 2003. The lead content of bones was measured by atomic absorption spectrophotometry, and corresponding stable lead isotopes (Pb204, 206, 207, 208) by inductively coupled plasma mass spectrometry. At the Glendye (N = 111) and Invermark (N = 85) estates, relatively few birds (5.4% and 3.5%, respectively) had highly elevated bone lead concentrations (> 20 mug/g dry weight). In bones of these highly exposed birds, a combination of Pb206:Pb207 and Pb208:Pb207ratios was consistent with ingestion of lead gunshot available in Europe. By contrast, Yorkshire grouse experienced a high incidence (65.8%) of bone lead > 20 mug/g. The Pb206:Pb207 and Pb208:Pb207ratios in bones of these highly exposed birds were consistent with a combined exposure to ingested lead gunshot and lead from galena mining in the region. Lead isotope ratios also indicated that lead from UK gasoline combustion and fallout from atmospheric particles was not a likely source of elevated lead in bones of either Scottish or Yorkshire grouse. Suggested management options for the three moors include adopting nontoxic shot for all game shooting on the estates, allowing heather (Calluna vulgaris) vegetation to grow tall in lead shot fall-out zones to reduce physical access to high densities of lead shot already present, and provision of calcareous grit across moors to reduce lead assimilation from all ingested sources of lead.

  7. Sources of variability in the determination by evaporation method of gross alpha activity in water samples

    Energy Technology Data Exchange (ETDEWEB)

    Baeza, A.; Corbacho, J.A. [LARUEX, Caceres (Spain). Environmental Radioactivity Lab.

    2013-07-01

    Determining the gross alpha activity concentration of water samples is one way to screen for waters whose radionuclide content is so high that its consumption could imply surpassing the Total Indicative Dose as defined in European Directive 98/83/EC. One of the most commonly used methods to prepare the sources to measure gross alpha activity in water samples is desiccation. Its main advantages are the simplicity of the procedure, the low cost of source preparation, and the possibility of simultaneously determining the gross beta activity. The preparation of the source, the construction of the calibration curves, and the measurement procedure itself involve, however, various factors that may introduce sufficient variability into the results to significantly affect the screening process. We here identify the main sources of this variability, and propose specific procedures to follow in the desiccation process that will reduce the uncertainties, and ensure that the result is indeed representative of the sum of the activities of the alpha emitters present in the sample. (orig.)

  8. Theoretical and experimental determination of dosimetric characteristics for ADVANTAGETM Pd-103 brachytherapy source

    International Nuclear Information System (INIS)

    Meigooni, Ali S.; Dini, Sharifeh A.; Awan, Shahid B.; Dou, Kai; Koona, Rafiq A.

    2006-01-01

    ADVANTAGE TM Pd-103 brachytherapy source has been recently introduced by IsoAid TM for prostate permanent implants. Dosimetric characteristics (Dose rate constant, radial dose function, 2D-, and 1D-anisotropy functions) of this source model have been determined using both theoretical and experimental methods, following the updated TG-43U1 protocol. Derivation of the dose rate constant was based on recent NIST WAFAC calibration performed in accordance with the 1999 Standards. Measurements were performed in Solid Water TM using LiF TLD chips and the theoretical calculations were performed in Solid Water TM and liquid water phantom materials using PTRAN Monte Carlo code. The results of the Monte Carlo simulation have shown a dose rate constant of 0.69 cGy h -1 U -1 in liquid water and 0.67 cGy h -1 U -1 in Solid Water TM medium. The measured dose rate constant in Solid Water TM was found to be 0.68±8% cGy h -1 U -1 , which is in a good agreement (within ±5%) to the Monte Carlo simulated data. The 2D- and 1D-anisotropy functions of the ADVANTAGE TM Pd-103 source were calculated for radial distances ranging from 0.5 to 5.0 cm. Radial dose function was determined for radial distances ranging from 0.2 to 8.0 cm using line source approximation. All these calculations are based on L eff equal to 3.61 cm, calculated following TG-43U1 recommendations. The tabulated data for 2D-anisotropy function, 1D-anisotropy function, dose rate constant and radial dose function have been produced for clinical application of this source model

  9. Determination of activation level energy of nuclear isomers by calibration of microspectra of radioactive sources

    International Nuclear Information System (INIS)

    Veres, A.; Pavlicsek, I.

    1980-01-01

    Nuclear isomers with unknown activation level were irradiated by calibrated radioactive sources. The integral cross sections were calculated for different energies of the sources. The activation energy was given by values coinciding with each other within the limits of error. The method made the determination of the unknown level of 1180+-10 keV of 195 Pt nucleus possible. (author)

  10. Determination of Lung-to-Blood Absorption Rates for Lead and Bismuth which are Appropriate for Radon Progeny

    International Nuclear Information System (INIS)

    Marsh, J.W.; Birchall, A.

    1999-01-01

    The ICRP Publication 66 Human Respiratory Tract Model (HRTM) treats clearance as a competitive process between absorption into blood and particle transport to the gastrointestinal tract and lymphatics. The ICRP recommends default absorption rates for lead and bismuth in ICRP Publication 71 but states that the values are not appropriate for short-lived radon progeny. This paper describes an evaluation of published data from volunteer experiments to estimate the absorption half-times of lead and bismuth that are appropriate for short-lived radon progeny. The absorption half-time for lead was determined to be 10±2 h, based on 212 Pb lung and blood retention data from several studies. The absorption half-time for bismuth was estimated to be about 13 h, based on 212 Bi urinary excretion data from one experiment and the ICRP biokinetic model for bismuth as a decay product of lead. (author)

  11. Food contamination as a pathway for lead exposure in children during the 2010-2013 lead poisoning epidemic in Zamfara, Nigeria.

    Science.gov (United States)

    Tirima, Simba; Bartrem, Casey; von Lindern, Ian; von Braun, Margrit; Lind, Douglas; Anka, Shehu Mohamed; Abdullahi, Aishat

    2018-05-01

    In 2010, an estimated 400 to 500 children died of acute lead poisoning associated with artisanal gold mining in Zamfara, Nigeria. Processing of gold ores containing up to 10% lead within residential compounds put residents, especially children, at the highest risk. Principal routes of exposure were incidental ingestion and inhalation of contaminated soil and dusts. Several Nigerian and international health organizations collaborated to reduce lead exposures through environmental remediation and medical treatment. The contribution of contaminated food to total lead exposure was assessed during the environmental health response. Objectives of this investigation were to assess the influence of cultural/dietary habits on lead exposure pathways and estimate the contribution of contaminated food to children's blood lead levels (BLLs). A survey of village dietary practices and staple food lead content was conducted to determine dietary composition, caloric intakes, and lead intake. Potential blood lead increments were estimated using bio-kinetic modeling techniques. Most dietary lead exposure was associated with contamination of staple cereal grains and legumes during post-harvest processing and preparation in contaminated homes. Average post-harvest and processed cereal grain lead levels were 0.32mg/kg and 0.85mg/kg dry weight, respectively. Age-specific food lead intake ranged from 7 to 78μg/day. Lead ingestion and absorption were likely aggravated by the dusty environment, fasting between meals, and nutritional deficiencies. Contamination of staple cereal grains by highly bioavailable pulverized ores could account for as much as 11%-34% of children's BLLs during the epidemic, and were a continuing source after residential soil remediation until stored grain inventories were exhausted. Copyright © 2017. Published by Elsevier B.V.

  12. Determination of the Absolute Disintegration Rate of Cs-137 sources by the Tracer Method

    Energy Technology Data Exchange (ETDEWEB)

    Hellstroem, S; Brune, D

    1963-07-15

    {sup 137}Cs - sources were absolutely measured by the 'tracer method', with {sup 82}Br as a tracer nuclide and with application of the 4{pi} {beta}-{gamma} coincidence technique. A self-absorption of 6 % was found in sources obtained from a solution with a carrier-content of 400 {mu}g/ml. The precision of the method for the determination of the {beta}-emission rate was estimated to {+-} 1 %. The results were compared with those of other works.

  13. Determination of the Absolute Disintegration Rate of Cs-137 sources by the Tracer Method

    International Nuclear Information System (INIS)

    Hellstroem, S.; Brune, D.

    1963-07-01

    137 Cs - sources were absolutely measured by the 'tracer method', with 82 Br as a tracer nuclide and with application of the 4π β-γ coincidence technique. A self-absorption of 6 % was found in sources obtained from a solution with a carrier-content of 400 μg/ml. The precision of the method for the determination of the β-emission rate was estimated to ± 1 %. The results were compared with those of other works

  14. Preconcentration, Separation and Determination of lead(II) with Methyl Thymol Blue Adsorbed on Activated Carbon Using Flame Atomic Absorption Spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Ensafi, Ali A.; Ghaderi, Ali R. [Isfahan University of Technology, Isfahan (Iran, Islamic Republic of)

    2008-02-15

    An on-line system for preconcentration and separation of lead(II) is presented. The method is based on the complex formation of Pb(II) with adsorbed Methyl thymol blue on activated carbon. The conditions of preparing the solid phase reagent and of quantitative recovery of Pb(II) from diluted solutions, such as acidity of aqueous phase, solid phase capacity, and flow variables were studied as well as effect of potential interfering ions. After preconcentration step, the metal ions are eluted automatically by 5 ml of 0.5 M HNO{sub 3} solution and the lead ions content was determined by flame atomic absorption spectrometry. Under the optimum conditions, the lead ions in aqueous samples were separated and preconcentrated about 1000-fold by the column. The detection limit was 0.001 μg mL{sup -1}. Lead has been determined in river and tap water samples, with recovery of 98 to 102%.

  15. Exposure to lead in South African shooting ranges

    International Nuclear Information System (INIS)

    Mathee, Angela; Jager, Pieter de; Naidoo, Shan; Naicker, Nisha

    2017-01-01

    Introduction: Lead exposure in shooting ranges has been under scrutiny for decades, but no information in this regard is available in respect of African settings, and in South Africa specifically. The aim of this study was to determine the blood lead levels in the users of randomly selected private shooting ranges in South Africa's Gauteng province. Methods: An analytical cross sectional study was conducted, with participants recruited from four randomly selected shooting ranges and three archery ranges as a comparator group. Results: A total of 118 (87 shooters and 31 archers) were included in the analysis. Shooters had significantly higher blood lead levels (BLL) compared to archers with 36/85 (42.4%) of shooters versus 2/34 (5.9%) of archers found to have a BLL ≥10 μg/dl (p<0.001). Conclusion: Shooting ranges may constitute an import site of elevated exposure to lead. Improved ventilation, low levels of awareness of lead hazards, poor housekeeping, and inadequate personal hygiene facilities and practices at South African shooting ranges need urgent attention. - Highlights: • This is the first study, to our knowledge, of lead exposure in shooting ranges in an African setting. • This study indicates highly elevated lead exposure amongst the users of certain private shooting ranges in South Africa. • Lead exposure may be a serious, yet under-studied, source of adult lead exposure in South Africa, and possibly elsewhere on the African continent.

  16. Exposure to lead in South African shooting ranges

    Energy Technology Data Exchange (ETDEWEB)

    Mathee, Angela [South African Medical Research Council, Environment & Health Research Unit, PO Box 87373, Houghton 2041 (South Africa); University of the Witwatersrand (School of Public Health), PO Box Wits, Johannesburg 2050 (South Africa); University of Johannesburg (Environmental Health Department, Faculty of Health Sciences), PO Box 524, Auckland Park, Johannesburg 2006 (South Africa); Jager, Pieter de [University of the Witwatersrand (School of Public Health), PO Box Wits, Johannesburg 2050 (South Africa); National Health Laboratory Service (Epidemiology and Surveillance Unit, National Institute for Occupational Health), PO Box 4788, Johannesburg 2000 (South Africa); Naidoo, Shan [University of the Witwatersrand (School of Public Health), PO Box Wits, Johannesburg 2050 (South Africa); Naicker, Nisha [South African Medical Research Council, Environment & Health Research Unit, PO Box 87373, Houghton 2041 (South Africa); University of the Witwatersrand, School of Public Health, PO Box Wits, Johannesburg 2050 (South Africa); University of Johannesburg, Environmental Health Department, Faculty of Health Sciences, PO Box 524, Auckland Park, Johannesburg 2006 (South Africa)

    2017-02-15

    Introduction: Lead exposure in shooting ranges has been under scrutiny for decades, but no information in this regard is available in respect of African settings, and in South Africa specifically. The aim of this study was to determine the blood lead levels in the users of randomly selected private shooting ranges in South Africa's Gauteng province. Methods: An analytical cross sectional study was conducted, with participants recruited from four randomly selected shooting ranges and three archery ranges as a comparator group. Results: A total of 118 (87 shooters and 31 archers) were included in the analysis. Shooters had significantly higher blood lead levels (BLL) compared to archers with 36/85 (42.4%) of shooters versus 2/34 (5.9%) of archers found to have a BLL ≥10 μg/dl (p<0.001). Conclusion: Shooting ranges may constitute an import site of elevated exposure to lead. Improved ventilation, low levels of awareness of lead hazards, poor housekeeping, and inadequate personal hygiene facilities and practices at South African shooting ranges need urgent attention. - Highlights: • This is the first study, to our knowledge, of lead exposure in shooting ranges in an African setting. • This study indicates highly elevated lead exposure amongst the users of certain private shooting ranges in South Africa. • Lead exposure may be a serious, yet under-studied, source of adult lead exposure in South Africa, and possibly elsewhere on the African continent.

  17. Effect on blood lead of airborne lead particles characterized by size.

    Science.gov (United States)

    Park, Dong-Uk; Paik, Nam-Won

    2002-03-01

    Worker exposure to airborne lead particles was evaluated for a total of 117 workers in 12 work-places of four different industrial types in Korea. The particle sizes were measured using 8-stage cascade impactors worn by the workers. Mass median aerodynamic diameters (MMAD) were determined by type of industry and percentage of lead particles as a fraction of airborne lead (PbA) concentration was determined by particle size. Blood lead (PbB) levels of workers who matched airborne lead samples were also examined. A Scheffé's pairwise comparison test showed that MMAD and the fractions of each of respirable particles and lead particles lead particles lead particles (r = 0.82) than that between concentrations of small particles and PbA (r = 0.61). A simple linear regression indicated that PbB correlated better with respirable lead concentration (r2 = 0.35, P = 0.0001) than with PbA concentration and had a higher slope coefficient. Controlling for respirable lead concentration reduced the partial correlation coefficient between PbA concentration and PbB level from 0.56 to 0.20 (P = 0.053). The results indicate that the contribution of respirable lead particles to lead absorption would be greater than that of PbA. This study concludes that the measurement of PbA only may not properly reflect a worker's exposure to lead particles with diverse characteristics. For the evaluation of a worker's exposure to various types of lead particles, it is recommended that respirable lead particles as well as PbA be measured.

  18. Lead in teeth from lead-dosed goats: Microdistribution and relationship to the cumulative lead dose

    International Nuclear Information System (INIS)

    Bellis, David J.; Hetter, Katherine M.; Jones, Joseph; Amarasiriwardena, Dula; Parsons, Patrick J.

    2008-01-01

    Teeth are commonly used as a biomarker of long-term lead exposure. There appear to be few data, however, on the content or distribution of lead in teeth where data on specific lead intake (dose) are also available. This study describes the analysis of a convenience sample of teeth from animals that were dosed with lead for other purposes, i.e., a proficiency testing program for blood lead. Lead concentration of whole teeth obtained from 23 animals, as determined by atomic absorption spectrometry, varied from 0.6 to 80 μg g -1 . Linear regression of whole tooth lead (μg g -1 ) on the cumulative lead dose received by the animal (g) yielded a slope of 1.2, with r 2 =0.647 (p -1 , were found in circumpulpal dentine. Linear regression of circumpulpal lead (μg g -1 ) on cumulative lead dose (g) yielded a slope of 23 with r 2 =0.961 (p=0.0001). The data indicated that whole tooth lead, and especially circumpulpal lead, of dosed goats increased linearly with cumulative lead exposure. These data suggest that circumpulpal dentine is a better biomarker of cumulative lead exposure than is whole tooth lead, at least for lead-dosed goats

  19. Estimation of lead sources in a Japanese cedar ecosystem using stable isotope analysis

    International Nuclear Information System (INIS)

    Itoh, Yuko; Noguchi, Kyotaro; Takahashi, Masamichi; Okamoto, Toru; Yoshinaga, Shuichiro

    2007-01-01

    Anthropogenic Pb affects the environment worldwide. To understand its effect on forest ecosystem, Pb isotope ratios were determined in precipitation, various components of vegetation, the forest floor, soil and parent material in a Japanese cedar (Cryptomeria japonica D. Don) forest stand. The average 206 Pb/ 207 Pb ratio in bulk precipitation was 1.14 ± 0.01 (mean ± SD), whereas that in the subsoil (20-130 cm) was 1.18 ± 0.01. Intermediate ratios ranging from 1.15 to 1.16 were observed in the vegetation, the forest floor, and the surface soil (0-10 cm). Using the 206 Pb/ 207 Pb ratios, the contribution of anthropogenic sources to Pb accumulated in the forest were estimated by the simple binary mixing model. Sixty-two percent of the Pb in the forest floor, 71% in the vegetation, and 55% in the surface soil (0-10 cm) originated from anthropogenic sources, but only 16% in the sub-surface soil (10-20 cm) was anthropogenic. These results suggest that internal Pb cycling occurs mainly between surface soil and vegetation in a Japanese cedar ecosystem, and that anthropogenic Pb strongly influences Pb cycling. Although the Japanese cedar ecosystem has a shallow forest floor, very little atmospherically derived Pb migrated downward over 10 cm in depth

  20. Depth determination of buried caesium-137 and cobalt-60 sources using scatter peak data

    International Nuclear Information System (INIS)

    Adams, J. C.; Joyce, M. J.; Mellor, M.

    2009-01-01

    An investigation into an alternative approach to 3D (3-dimensional) source mapping is proposed, by combining the insights of two existing techniques. The first of these is a 3D 'imaging' tool, N-Visage TM that has been developed by REACT Engineering Ltd. This technique is efficient and robust, but is not a true 3D technique as it relies on user-supplied 2D (2-dimensional) manifolds to constrain source locations. The second technique uses the γ-photopeak and an X-ray peak to determine radionuclide source depth using a relative attenuation method. We look at the possibility of combining both techniques to constrain both the location and depth of a radiological source buried under shielding. It is believed a combined method using spectra recorded above the shielding object will be of use in the nuclear decommissioning and land contamination industries. N-Visage TM has previously been used to map source distributions of mixed radionuclides with complex geometries through shielding media. The software works by producing a computer model which recreates the experimental setup. A survey is imported, comprising a set of γ-spectra recorded with an instrument of known efficiency and isotropy taken at a variety of locations around the area of interest. A survey plan recording the location and orientation of the instrument for each reading is also reconstructed. N-Visage TM is then able to determine the locations of the source(s) without prior knowledge of exactly where they are located, by building and inverting a simple physical model relating potential source locations to the recorded spectra. This research sets out to investigate the possibility of combining the geometric insights of N-Visage TM with a method of extracting depth information from scatter data, rather than the X-ray peak. By combining the γ-photopeak and scatter areas of a spectrum, the thickness of the shielding media between source and detector can potentially be inferred. Using scattered photons rather

  1. General population exposure of stable lead and 210Pb to residents of New York City

    International Nuclear Information System (INIS)

    Bogen, D.C.; Welford, G.A.; Morse, R.

    1975-12-01

    Stable lead and 210 Pb intake, ingestion, and inhalation by residents of New York City were determined. Measurement of excreta samples provided data to establish a mass balance of stable lead and 210 Pb. These results indicate that no more than 5 μg of stable lead and 0.1 pCi of 210 Pb are retained daily by residents of New York City. Analyses of bone samples have provided estimates of the skeletal burden of stable lead and 210 Pb. Using the ICRP model, intake data, and assuming 100 percent skeletal deposition, the calculated stable lead and 210 Pb values are in good agreement with the experimental results. The data indicate that inhalation is the principle source of stable lead to residents in New York City

  2. Lead isotopes and trace metal ratios of aerosols as tracers of Pb pollution sources in Kanpur, India

    Science.gov (United States)

    Sen, Indra; Bizimis, Michael; Tripathi, Sachchida; Paul, Debajyoti; Tyagi, Swati; Sengupta, Deep

    2015-04-01

    The anthropogenic flux of Pb in the Earth's surface is almost an order of magnitude higher than its corresponding natural flux [1]. Identifying the sources and pathways of anthropogenic Pb in environment is important because Pb toxicity is known to have adverse effects on human health. Pb pollution sources for America, Europe, and China are well documented. However, sources of atmospheric Pb are unknown in India, particularly after leaded gasoline was phased out in 2000. India has a developing economy with a rapidly emerging automobile and high temperature industry, and anthropogenic Pb emission is expected to rise in the next decade. In this study, we report on the Pb- isotope compositions and trace metal ratios of airborne particulates collected in Kanpur, an industrial city in northern India. The Pb concentration in the airborne particulate matter varies between 14-216 ng/m3, while the other heavy metals vary by factor of 10 or less, e.g. Cd=0.3-3 ng/m3, As=0.4-3.5 ng/m3, Zn=36-161 ng/m3, and Cu=3-22 ng/m3. The 206Pb/207Pb, 208Pb/206Pb, and 208Pb/207Pb vary between 1.112 - 1.129, 2.123-2.141, and 2.409-2.424 respectively, and are highly correlated with each other (R2>0.9). Pb isotopes and trace metal data reveals that coal combustion is the major source of anthropogenic Pb in the atmosphere, with limited contribution from mining and smelting processes. We further conclude that combination of Pb isotope ratios and V/Pb ratios are powerful tracers for Pb source apportionment studies, which is otherwise difficult to differentiate based only on Pb systematics [1] Sen and Peucker-Ehrenbrink (2012), Environ. Sci. Technol.(46), 8601-8609

  3. Determination of noise sources and space-dependent reactor transfer functions from measured output signals only

    Energy Technology Data Exchange (ETDEWEB)

    Hoogenboom, J.E.; van Dam, H.; Kleiss, E.B.J.; van Uitert, G.C.; Veldhuis, D.

    1982-01-01

    The measured cross power spectral densities of the signals from three neutron detectors and the displacement of the control rod of the 2 MW research reactor HOR at Delft have been used to determine the space-dependent reactor transfer function, the transfer function of the automatic reactor control system and the noise sources influencing the measured signals. From a block diagram of the reactor with control system and noise sources expressions were derived for the measured cross power spectral densities, which were adjusted to satisfy the requirements following from the adopted model. Then for each frequency point the required transfer functions and noise sources could be derived. The results are in agreement with those of autoregressive modelling of the reactor control feed-back loop. A method has been developed to determine the non-linear characteristics of the automatic reactor control system by analysing the non-gaussian probability density function of the power fluctuations.

  4. Determination of noise sources and space-dependent reactor transfer functions from measured output signals only

    International Nuclear Information System (INIS)

    Hoogenboom, J.E.

    1982-01-01

    The measured cross power spectral densities of the signals from three neutron detectors and the displacement of the control rod of the 2 MW research reactor HOR at Delft have been used to determine the space-dependent reactor transfer function, the transfer function of the automatic reactor control system and the noise sources influencing the measured signals. From a block diagram of the reactor with control system and noise sources expressions were derived for the measured cross power spectral densities, which were adjusted to satisfy the requirements following from the adopted model. Then for each frequency point the required transfer functions and noise sources could be derived. The results are in agreement with those of autoregressive modelling of the reactor control feed-back loop. A method has been developed to determine the non-linear characteristics of the automatic reactor control system by analysing the non-gaussian probability density function of the power fluctuations. (author)

  5. The effects of lead sources on oral bioaccessibility in soil and implications for contaminated land risk management

    International Nuclear Information System (INIS)

    Palmer, Sherry; McIlwaine, Rebekka; Ofterdinger, Ulrich; Cox, Siobhan F.; McKinley, Jennifer M.; Doherty, Rory; Wragg, Joanna; Cave, Mark

    2015-01-01

    Lead (Pb) is a non-threshold toxin capable of inducing toxic effects at any blood level but availability of soil screening criteria for assessing potential health risks is limited. The oral bioaccessibility of Pb in 163 soil samples was attributed to sources through solubility estimation and domain identification. Samples were extracted following the Unified BARGE Method. Urban, mineralisation, peat and granite domains accounted for elevated Pb concentrations compared to rural samples. High Pb solubility explained moderate-high gastric (G) bioaccessible fractions throughout the study area. Higher maximum G concentrations were measured in urban (97.6 mg kg −1 ) and mineralisation (199.8 mg kg −1 ) domains. Higher average G concentrations occurred in mineralisation (36.4 mg kg −1 ) and granite (36.0 mg kg −1 ) domains. Findings suggest diffuse anthropogenic and widespread geogenic contamination could be capable of presenting health risks, having implications for land management decisions in jurisdictions where guidance advises these forms of pollution should not be regarded as contaminated land. - Highlights: • Urban, mineralisation, peat and granite sources accounted for elevated Pb in soil. • Pb solubility was higher in urban and mineralisation domains. • Higher Pb solubility resulted in high oral bioaccessibility compared to rural areas. • Diffuse background and natural Pb contamination could pose human health risks. • Contaminated land policy should not dismiss diffuse or geogenic pollution sources. - Diffuse and widespread Pb sources displayed high oral bioaccessibility, providing implications for contaminated land risk assessment guidance that excludes these forms of pollution

  6. Dosimetry audit on the accuracy of {sup 192}Ir brachytherapy source strength determinations in Sweden

    Energy Technology Data Exchange (ETDEWEB)

    Carlsson Tedgren, Aasa

    2007-11-15

    The absorbed dose delivered to the patient in brachytherapy is directly proportional to the source strength in terms of the reference air-kerma rate (RAKR). Verification of this quantity by the hospitals is widely recognized as an important part of a quality assurance program. An external audit was performed on behalf of the Secondary Standard Dosimetry Laboratory at the Swedish Radiation Protection Authority (SSI). The aim was to investigate how accurately the source-strength in {sup 192}Ir brachytherapy is determined at Swedish hospitals. The SSI reference well-type ion chamber and calibrated equipment were used to measure the RAKR of an {sup 192}Ir source in each of the 14 Swedish afterloading units. Comparisons with values determined by vendors and hospitals were made. Agreement in values of RAKR as determined by SSI, hospitals and vendors were in all cases within the {+-}3% uncertainty (at a coverage factor of k=2), typically guaranteed by the vendors. The good agreement reflects the robustness and easy handling of well-type chambers designed for brachytherapy in use by all Swedish hospitals. The {sup 192}Ir calibration service planned at SSI will solve the hospitals current problem with recalibration of equipment. SSI can also advise hospitals to follow the IAEA recommendations for measurement techniques and maintenance of equipment. It is worthwhile for the hospitals to establish their own ratio (or deviation) with the vendor and follow it as function of time. Such a mean-ratio embeds systematic differences of various origins and have a lower uncertainty than has the RAKR alone, making it useful for early detection of problems with equipment or routines. SSI could also define requirements for the agreement between source strengths as determined by hospitals and vendors and couple this to an action plan, dependent on level of disagreement, and some kind of reporting to SSI.

  7. Determination of silver, bismuth, cadmium, copper, lead, and zinc in geologic materials by atomic absorption spectrometry with tricaprylylmethylammonium chloride

    Science.gov (United States)

    Viets, J.G.

    1978-01-01

    Interferences commonly encountered in the determination of silver, bismuth, cadmium, copper, lead, and zinc at crustal abundance levels are effectively eliminated using a rapid, sensitive, organic extraction technique. A potassium chlorate-hydrochloric acid digestion solubilizes the metals not tightly bound in the silicate lattice of rocks, soils, and stream sediments. The six metals are selectively extracted into a 10% Aliquat 336-MIBK organic phase in the presence of ascorbic acid and potassium iodide. Metals in the organic extract are determined by flame atomic absorption spectrometry to the 0.02-ppm level for silver, cadmium, copper, and zinc and to the 0.2-ppm level for bismuth and lead with a maximum relative standard deviation of 18.8% for known reference samples. An additional hydrofluoric acid digestion may be used to determine metals substituted in the silicate lattice.

  8. [Determination of Trace Lead in Water by UV-Visible Diffuse Reflectance Spectroscopy Combined with Surfactant and Membrane Filtration-Enrichment].

    Science.gov (United States)

    Zhang, Xiao-fang; Zhu, Bi-lin; Li, Wei; Wang, Lei; Zhang, Lei; Wu, Ting; Du, Yi-ping

    2015-07-01

    In this paper, a method of determination of trace lead in water by UV-Visible diffuse reflectance spectroscopy combined with surfactant and membrane filtration enrichment was proposed. In the NH3 x H2O-NH4Cl buffer solution with pH 8.5, the lead(II) ion would react with dithizone to form the red complex under vigorous stirring, which is hydrophobic and can be enriched by the mixed cellulose ester membrane. In addition, the nonionic surfactant Polyoxyethylene lauryl ether (Brij-30) was added into the solution to improve the enrichment efficiency, then visible diffuse reflectance spectra of the membrane were measured directly after the membrane were naturally dried. We also optimized the reaction conditions which may affect the complexation reaction process, such as type of surfactants, the concentration of the surfactant, the reaction acidity, the concentration of dithizone as well as the reaction time. The research results show that under the optimum conditions, a good linear correlation between absorbance at 485 nm and concentration of lead in the range of 5.0-100.0 microg x L(-1) was obtained with a squared correlation coefficient (R2) of 0.9906, and the detection limit was estimated accordingly to be 2.88 microg x L(-1). To determine real water sample, the interference from some potential coexisting ions was also studied at the optimal conditions when the concentration of lead (II) ion standard solution was fixed to 20 microg x L(-1). The results indicate that the following ions cannot interfere in the determination of lead with the proposed method: 500 times of the K+, Na+, Ca2+, Mg2+, NH4+, NO3-, Cl-, CH3COO-, SO4(2-); 10 times of the Al3+ (using 10% NaF as a masking reagent to avoid the interference); 10 times of the Fe3+ (using 10% NaF and 10% sodium potassium tartrate as masking reagents); 10 times of Hg2+ or Zn2+ (using 10% NaSCN and 10% potassium sodium tartrate as masking reagents); the same amount of Cd2+, Cu2+. The proposed method was applied to the

  9. Lead theft--a study of the "uniqueness" of lead from church roofs.

    Science.gov (United States)

    Bond, John W; Hainsworth, Sarah V; Lau, Tien L

    2013-07-01

    In the United Kingdom, theft of lead is common, particularly from churches and other public buildings with lead roofs. To assess the potential to distinguish lead from different sources, 41 samples of lead from 24 church roofs in Northamptonshire, U.K, have been analyzed for relative abundance of trace elements and isotopes of lead using X-ray fluorescence (XRF) and inductively coupled plasma mass spectrometry, respectively. XRF revealed the overall presence of 12 trace elements with the four most abundant, calcium, phosphorus, silicon, and sulfur, showing a large weight percentage standard error of the mean of all samples suggesting variation in the weight percentage of these elements between different church roofs. Multiple samples from the same roofs, but different lead sheets, showed much lower weight percentage standard errors of the mean suggesting similar trace element concentrations. Lead isotope ratios were similar for all samples. Factors likely to affect the occurrence of these trace elements are discussed. © 2013 American Academy of Forensic Sciences.

  10. An assessment of contemporary atomic spectroscopic techniques for the determination of lead in blood and urine matrices

    Science.gov (United States)

    Parsons, Patrick J.; Geraghty, Ciaran; Verostek, Mary Frances

    2001-09-01

    The preparation and validation of a number of clinical reference materials for the determination of lead in blood and urine is described. Four candidate blood lead reference materials (Lots, 047-050), and four candidate urine lead reference materials (Lots, 034, 035, 037 and 038), containing physiologically-bound lead at clinically relevant concentrations, were circulated to up to 21 selected laboratories specializing in this analysis. Results from two interlaboratory studies were used to establish certified values and uncertainty estimates for these reference materials. These data also provided an assessment of current laboratory techniques for the measurement of lead in blood and urine. For the blood lead measurements, four laboratories used electrothermal atomization AAS, three used anodic stripping voltammetry and one used both ETAAS and ICP-MS. For the urine lead measurements, 11 laboratories used ETAAS (most with Zeeman background correction) and 10 used ICP-MS. Certified blood lead concentrations, ±S.D., ranged from 5.9±0.4 μg/dl (0.28±0.02 μmol/l) to 76.0±2.2 μg/dl (3.67±0.11 μmol/l) and urine lead concentrations ranged from 98±5 μg/l (0.47±0.02 μmol/l) to 641±36 μg/l (3.09±0.17 μmol/l). The highest concentration blood lead material was subjected to multiple analyses using ETAAS over an extended time period. The data indicate that more stringent internal quality control practices are necessary to improve long-term precision. While the certification of blood lead materials was accomplished in a manner consistent with established practices, the urine lead materials proved more troublesome, particularly at concentrations above 600 μg/l (2.90 μmol/l).

  11. Relationship between the pitch of modulation collimators and the determination accuracy of source positions

    International Nuclear Information System (INIS)

    Fujii, Masami; Nishimura, Jun

    1989-01-01

    The celestial positions of X-ray bursters and gamma-ray burst sources can be accurately determined with rotating modulation collimators which possess wide fields of view and also high angular resolutions. Since the determination accuracy is dependent on the signal to noise ratio of incident photons, the distribution of signal power is analysed and the optimum pitch of the modulation collimator for a burst of a given size is discussed. (author)

  12. Preconcentration of lead using solidification of floating organic drop and its determination by electrothermal atomic absorption spectrometry

    Directory of Open Access Journals (Sweden)

    Mahmoud Chamsaz

    2013-07-01

    Full Text Available A simple microextraction method based on solidification of a floating organic drop (SFOD was developed for preconcentration of lead prior to its determination by electrothermal atomic absorption spectrometry (ETAAS. Ammonium pyrolidinedithiocarbamate (APDC was used as complexing agent, and the formed complex was extracted into a 20 μL of 1-undecanol. The extracted complex was diluted with ethanol and injected into a graphite furnace. An orthogonal array design (OAD with OA16 (45 matrix was employed to study the effects of different parameters such as pH, APDC concentration, stirring rate, sample solution temperature and the exposure time on the extraction efficiency. Under the optimized experimental conditions the limit of detection (based on 3 s and the enhancement factor were 0.058 μg L−1 and 113, respectively. The relative standard deviation (RSD for 8 replicate determinations of 1 μg L−1 of Pb was 8.8%. The developed method was validated by the analysis of certified reference materials and was successfully applied to the determination of lead in water and infant formula base powder samples.

  13. Electrochemical stripping determination of traces of copper, lead, cadmium and zinc in zirconium metal and zirconium dioxide

    International Nuclear Information System (INIS)

    Stulik, K.; Beran, P.; Dolezal, J.; Opekar, F.

    1978-01-01

    Procedures have been developed for the determination of copper, lead, cadmium and zinc in zirconium metal and zirconium dioxide, at concentrations of 1ppm or less. Zirconium metal was dissolved in sulphuric acid, and zirconium dioxide decomposed under pressure with hydrofluoric acid. Sample solutions were prepared in dilute sulphuric acid. For the stripping determination, the sample solution was either mixed with a complexing tartrate base electrolyte or the pre-electrolysis was carried out in acid solution, with the acid solution being exchanged for a pure base electrolyte (e.g. an acetate buffer) for the stripping step. The stripping step was monitored by d.c., differential pulse and Kalousek commutator voltammetry and the three methods were compared. A stationary mercury-drop electrode can generally be used for all the methods, whereas a mercury-film electrode is suitable only for the d.c. voltammetric determination of copper, lead and cadmium, as pulse measurements with films are poorly reproducible and the electrodes are easily damaged. The relative standard deviation does not exceed 20%. Some samples contained relatively large amounts of copper, which is best separated by electrodeposition on a platinum electrode. (author)

  14. Products and stability of phosphate reactions with lead under freeze-thaw cycling in simple systems

    International Nuclear Information System (INIS)

    Hafsteinsdottir, Erla G.; White, Duanne A.; Gore, Damian B.; Stark, Scott C.

    2011-01-01

    Orthophosphate fixation of metal contaminated soils in environments that undergo freeze-thaw cycles is understudied. Freeze-thaw cycling potentially influences the reaction rate, mineral chemical stability and physical breakdown of particles during fixation. This study determines what products form when phosphate (triple superphosphate [Ca(H 2 PO 4 ) 2 ] or sodium phosphate [Na 3 PO 4 ]) reacts with lead (PbSO 4 or PbCl 2 ) in simple chemical systems in vitro, and assesses potential changes in formation during freeze-thaw cycles. Systems were subjected to multiple freeze-thaw cycles from +10 deg. C to -20 deg. C and then analysed by X-ray diffractometry. Pyromorphite formed in all systems and was stable over multiple freeze-thaw cycles. Low temperature lead orthophosphate reaction efficiency varied according to both phosphate and lead source; the most time-efficient pyromorphite formation was observed when PbSO 4 and Na 3 PO 4 were present together. These findings have implications for the manner in which metal contaminated materials in freezing ground can be treated with phosphate. - Highlights: → Formation of lead phosphate products in cold environments is identified. → Potential change in formation during freeze-thaw cycling is assessed. → Lead phosphate reaction efficiency varies according to phosphate and lead source. → Pyromorphite formation is stable during 240 freeze-thaw cycles. - Pyromorphite, formed from Pb phosphate fixation, is stable during multiple freeze-thaw cycles but the efficiency of the fixation depends on the phosphate source and the type of Pb mineral.

  15. Regional lead isotope study of a polluted river catchment: River Wear, Northern England, UK

    Energy Technology Data Exchange (ETDEWEB)

    Shepherd, Thomas J., E-mail: shepherdtj@aol.com [Department of Earth Sciences, University of Durham, Science Laboratories, Durham DH1 3LE (United Kingdom); Chenery, Simon R.N. [British Geological Survey, Nicker Hill, Keyworth, Nottingham NG12 5GG (United Kingdom); Pashley, Vanessa [NERC Isotope Geosciences Laboratory, Kingsley Dunham Centre, Keyworth, Nottingham NG12 5GG (United Kingdom); Lord, Richard A. [School of Science and Technology, University of Teesside, Middlesbrough, Tees Valley TS1 3BA (United Kingdom); Ander, Louise E.; Breward, Neil; Hobbs, Susan F. [British Geological Survey, Nicker Hill, Keyworth, Nottingham NG12 5GG (United Kingdom); Horstwood, Matthew [NERC Isotope Geosciences Laboratory, Kingsley Dunham Centre, Keyworth, Nottingham NG12 5GG (United Kingdom); Klinck, Benjamin A. [British Geological Survey, Nicker Hill, Keyworth, Nottingham NG12 5GG (United Kingdom); Worrall, Fred [Department of Earth Sciences, University of Durham, Science Laboratories, Durham DH1 3LE (United Kingdom)

    2009-08-15

    High precision, lead isotope analyses of archived stream sediments from the River Wear catchment, northeast England (1986-88), provide evidence for three main sources of anthropogenic lead pollution; lead mining, industrial lead emissions and leaded petrol. In the upper catchment, pollution is totally controlled and dominated by large lead discharges from historic mining centres in the North Pennine Orefield ({sup 208}Pb/{sup 206}Pb, {sup 207}Pb/{sup 206}Pb ratios range from 2.0744-2.0954 and 0.8413-0.8554 respectively). In the lower catchment, co-extensive with the Durham Coalfield and areas of high population density, pollution levels are lower and regionally more uniform. Isotope ratios are systematically higher than in the upper catchment ({sup 208}Pb/{sup 206}Pb, {sup 207}Pb/{sup 206}Pb ratios range from 2.0856-2.1397 and 0.8554-0.8896 respectively) and far exceed values determined for the geogenic regional background. Here, the pollution is characterised by the atmospheric deposition of industrial lead and petrol lead. Lead derived from the combustion of coal, although present, is masked by the other two sources. Recent sediments from the main channel of the River Wear are isotopically indistinguishable from older, low order stream sediments of the North Pennine Orefield, indicating that contamination of the river by lead mining waste (up to several 1000 mg/kg Pb at some locations) continues to pose an environmental problem; a pattern that can be traced all the way to the tidal reach. Using within-catchment isotope variation and sediment lead concentrations, estimates can be made of the discharges from discrete mines or groups of mines to the overall level of lead pollution in the River Wear. As well as providing information pertinent to source apportionment and on-going catchment remediation measures, the database is a valuable resource for epidemiologists concerned with the health risks posed by environmental lead.

  16. Determination of the chemical yield on the Fricke dosimetry for 192Ir sources used in brachytherapy

    International Nuclear Information System (INIS)

    David, M.G.; Albuquerque, M.A.G.; Almeida, C.E. de; Rosado, P.H.

    2015-01-01

    With the aim of developing a primary standard for the absorbed dose to water, for the 192 Ir sources used in high dose rate brachytherapy, this work focuses on the determination of the chemical yield, G(Fe +3 ), using Fricke dosimetry, for the energy of those sources . The G(Fe +3 ) were determined the for three qualities of x-ray beams (150, 250 and 300 kV ) and for 60 Co energy. The G(Fe +3 ) value for the average energy of 192 Ir was obtained by linear fit, the found value was 1,555 ± 0,015 μmol/J. (author)

  17. Dietary exposure to lead in the Netherlands

    NARCIS (Netherlands)

    Boon PE; te Biesebeek JD; van Donkersgoed G; VVH; V&Z

    2017-01-01

    Uptake from the soil is the main route by which lead ends up in food. Lead in soil has its origin in both natural and anthropogenic sources. The lead concentration in food has decreased over the last decennia by the use of unleaded petrol and paint, and the replacement of lead water pipes.

  18. [Determination of trace lead and cadmium in transgenic rice by crosslinked carboxymethyl konjac glucomannan microcolumn preconcentration combined with graphite furnace atomic absorption spectrometry].

    Science.gov (United States)

    Liu, Hua-qing; Li, Sheng-qing; Qu, Yang; Chen, Hao

    2012-02-01

    A novel method was developed for the determination of trace lead and cadmium in transgenic brown rice based on separation and preconcentration with a micro column packed with crosslinked carboxymethyl konjac glucomannan (CCMKGM) prior to its determination by graphite furnace atomic absorption spectrometry. Variables affecting the separation and preconcentration of lead and cadmium, such as the acidity of the aqueous solution, sample flow rate and volume, and eluent concentration and volume, were optimized. Under optimized condition, detection limits of the method for the determination of trace lead and cadmium in transgenic brown rice were 0.11 and 0.002 microg x L(-1), respectively. The obtained results of lead and cadmium in the certified reference material (GBW10010, GBS1-1) were in good agreement with the certified values. The recoveries were in the range of 90%-103% and 93%-105% for detection of Pb and Cd in transgenic brown rice and the wild-type brown rice samples respectively. This study could provide technical support for determination of trace Pb and Cd in transgenic rice.

  19. Development of a technique for the determination of lead and bromine in atmospheric particles by X-ray fluorescence

    Science.gov (United States)

    Sturges, W. T.; Harrison, Roy M.; Dams, R.

    A methodology has been developed for determining the lead and bromine content of atmospheric particles collected on membrane filters. In a novel calibration procedure, standards were prepared by drying fine precipitates of lead molybdate and silver bromide on to filters. Such standards were evidently free from bromine loss during analysis and storage, and more accurately represent real samples than conventional solution-impregnated filters. Elemental loadings in the range 0.1-10μg could be measured. Inhomogeneous efficiency of detection across the surface of samples was noted, and was accounted for by applying correction factors obtained from an intercomparison of XRF and atomic absorption analyses. Good comparability between Br determinations by XRF and neutron activation analysis was found. Problems of noncomparability between standards and samples of low concentration were noted in some cases.

  20. Childhood Blood Lead Reductions Following Removal of Leaded Ceramic Glazes in Artisanal Pottery Production: A Success Story

    OpenAIRE

    Donald E. Jones, MS; Mario Covarrubias Pérez; Bret Ericson; Daniel Estrada Sánchez; Sandra Gualtero; Andrea Smith-Jones, MS; Jack Caravanos, DrPH, CIH

    2013-01-01

    Background. Lead exposure within artisanal ceramics workshop communities in Mexico continues to be a major source of childhood lead poisoning. Artisanal ceramics workshops expose children through direct ingestion, contaminated soil, and food prepared in lead-glazed pottery. Conversion to non-lead glazes alone may not effectively reduce exposure. This paper describes a model comprehensive intervention and environmental remediation of an artisanal ceramics workshop in the state of Hidalgo, Mexi...

  1. Determination of cadmium and lead species and phytochelatins in pea (Pisum sativum) by HPLC-ICPMS and HPLC-ESIMSn

    International Nuclear Information System (INIS)

    Baralkiewicz, D.; Magorzata, K.; Piechalak, A.; Tomaszewska, B.

    2009-01-01

    Full text: Trace elements play an important role in the functioning of life on our planet. Some of them can be highly toxic, whereas others can be essential. These effects are very often related to particular form in which the element is present. Often these different chemical forms of a particular element or its compounds are referred to as 'species'. Cadmium and lead are widespread heavy metal pollutants released into the environment by human activities. The presence of Pb 2+ and Cd 2+ in the environment leads to a numerous disturbances in many metabolic processes in plants. Inhibition of growth is a major symptom. Hyphenated techniques, such as HPLC-ICPMS and HPLC-ESIMSn seem to be the best analytical instruments to study metal speciation in plants. In our study, we used hyphenated techniques to identify compounds engaged in Cd and Pb metabolism and to perform analysis of metal complexes induced in Pisum sativum exposed to cadmium and lead. These identified compounds might be valuable source of information to study metal accumulation mechanism for bioremediation processes. (author)

  2. Derivative spectrophotometric determination of trace lead in alloys ...

    African Journals Online (AJOL)

    diethylaminophenol-ammonium tetraphenylborate with microcrystalline naphthalene or by a column method in the pH range 4.0–6.0 from a large volume of aqueous solutions of various samples. After filtration, the solid mass consisting of the lead complex and ...

  3. Seasonal variations in the sources of natural and anthropogenic lead deposited at the East Rongbuk Glacier in the high-altitude Himalayas.

    Science.gov (United States)

    Burn-Nunes, Laurie; Vallelonga, Paul; Lee, Khanghyun; Hong, Sungmin; Burton, Graeme; Hou, Shugui; Moy, Andrew; Edwards, Ross; Loss, Robert; Rosman, Kevin

    2014-07-15

    Lead (Pb) isotopic compositions and concentrations, and barium (Ba) and indium (In) concentrations have been analysed at sub-annual resolution in three sections from a snow pit samples dated to 2004/2005, recovered from the East Rongbuk Glacier in the high-altitude Himalayas. Ice core sections indicate that atmospheric chemistry prior to ~1,953 was controlled by mineral dust inputs, with no discernible volcanic or anthropogenic contributions. Eighteenth century monsoon ice core chemistry is indicative of dominant contributions from local Himalayan sources; non-monsoon ice core chemistry is linked to contributions from local (Himalayan), regional (Indian/Thar Desert) and long-range (North Africa, Central Asia) sources. Twentieth century monsoon and non-monsoon ice core data demonstrate similar seasonal sources of mineral dust, however with a transition to less-radiogenic isotopic signatures that suggests local and regional climate/environmental change. The snow pit record demonstrates natural and anthropogenic contributions during both seasons, with increased anthropogenic influence during non-monsoon times. Monsoon anthropogenic inputs are most likely sourced to South/South-East Asia and/or India, whereas non-monsoon anthropogenic inputs are most likely sourced to India and Central Asia. Copyright © 2014 Elsevier B.V. All rights reserved.

  4. DETERMINANTS OF THE ACCURACY OF NURSING DIAGNOSES : INFLUENCE OF READY KNOWLEDGE, KNOWLEDGE SOURCES, DISPOSITION TOWARD CRITICAL THINKING, AND REASONING SKILLS

    NARCIS (Netherlands)

    Paans, Wolter; Sermeus, Walter; Nieweg, Roos; Van der Schans, Cees

    2010-01-01

    The purpose of this study was to determine how knowledge sources, ready knowledge, and disposition toward critical thinking and reasoning skills influence the accuracy of student nurses' diagnoses. A randomized controlled trial was conducted to determine the influence of knowledge sources. We used

  5. Determinants of the accuracy of nursing diagnoses : influence of ready knowledge, knowledge sources, disposition toward critical thinking, and reasoning skills

    NARCIS (Netherlands)

    Paans, Wolter; Sermeus, Walter; Nieweg, Roos; van der Schans, Cees

    2010-01-01

    The purpose of this study was to determine how knowledge sources, ready knowledge, and disposition toward critical thinking and reasoning skills influence the accuracy of student nurses' diagnoses. A randomized controlled trial was conducted to determine the influence of knowledge sources. We used

  6. Lead isotopic studies of the Samail ophiolite, Oman

    Energy Technology Data Exchange (ETDEWEB)

    Chen, J.H.; Pallister, J.S.

    1981-04-10

    The isotopic composition of Pb and the concentrations of U, Th, and Pb have been determined for samples from various lithologic units and massive sulfides of the Samail ophiolite. The observed /sup 206/Pb//sup 204/Pb ratios range from 17.90 to 19.06, /sup 207/Pb//sup 204/Pb ratios from 15.43 to 15.63, and /sup 208/Pb//sup 204/Pb from 37.66 to 38.78. In Pb isotopic evolution diagrams, the initial Pb isotopic compositions of most of the samples from the Samail ophiolite plot within the field of oceanic basalt, clearly distinct from island arc data, and define some of the least radiogenic Pb observed from oceanic rocks. Lead data from the Samail are compatible with a model involving magma generation from an oceanic mantle source and formation of the ophiolite at an oceanic spreading center. U--Th--Pb isotopic systematics demonstrate that vertical heterogeneity in the oceanic crust can be created through differential concentration of U, Th, and Pb during crystal fractionation and alteration at, or near, the spreading ridge. Calcite form amygdules in the ophiolite basalt has similar Pb isotopic composition to the igneous rocks, suggesting precipitation of the calcite from seawater which contained Pb derived mostly from the oceanic crust. Lead isotopic data on Fe--Cu sulfides are also similar to the results from the igneous suite suggesting that the source of the sulfides is predominently from the oceanic crust. Lead data from serpentinized peridotite and a galena sample from below the ophiolite suggest that part of the serpentinization process and the formation of galena could involve addition of radiogenic Pb from either a continental source or from oceanic sediments.

  7. Lead Isotopic Compositions of Selected Coals, Pb/Zn Ores and Fuels in China and the Application for Source Tracing.

    Science.gov (United States)

    Bi, Xiang-Yang; Li, Zhong-Gen; Wang, Shu-Xiao; Zhang, Lei; Xu, Rui; Liu, Jin-Ling; Yang, Hong-Mei; Guo, Ming-Zhi

    2017-11-21

    Lead (Pb) pollution emission from China is becoming a potential worldwide threat. Pb isotopic composition analysis is a useful tool to accurately trace the Pb sources of aerosols in atmosphere. In this study, a comprehensive data set of Pb isotopes for coals, Pb/Zn ores, and fuels from China was presented. The ratios of 206 Pb/ 207 Pb and 208 Pb/ 206 Pb in the coals were in the range of 1.114-1.383 and 1.791-2.317, similar to those from Europe, Oceania, and South Asia, but different from those from America (p fuels from in coals. Urban aerosols demonstrated similar Pb isotopic compositions to coals, Pb/Zn ores, and fuels in China. After removing the leaded gasoline, the Pb in aerosols is more radiogenic, supporting the heavy contribution of coal combustion to the atmospheric Pb pollution.

  8. Determination of lead in red wine for CCQM-K30 international comparison by using ID-ICPMS

    International Nuclear Information System (INIS)

    Zhou Tao; Wang Jun; Lu Hai; Zhao Motian

    2007-01-01

    The content of lead in red wine for CCQM-K30 international key comparison is determined by using isotope dilution mass spectrometry (IDMS). This test almost reach detect limit of the method because the content of lead in red wine was only 3 ng/g and the procedure blank was about 0.3 ng. The comparison results indicate that it is easy to achieve agreements using IDMS. In uncertainty analysis, all of the factors about IDMS method were considered. But, procedure blank took great inference to experiment precision and enlarged the total uncertainty. Therefore the controls of procedure blank were very important for the analysis of ultra-trace concentration of samples. (authors)

  9. Treating Lead Toxicity: Possibilities beyond Synthetic Chelation

    Directory of Open Access Journals (Sweden)

    Shambhavi Tannir

    2013-01-01

    Full Text Available Lead, a ubiquitous metal, is one of the most abundant elements present on earth. Its easy availability and cost effectiveness made it an extremely popular component in the industrial revolution. However, its hazardous health effects were not considered at the time. Over the last few decades, with the adverse effects of lead coming to the forefront, nations across the world have started to recognize and treat lead toxicity. The most reliable and used method until now has been chelation therapy. Recent research has suggested the use of natural products and sources to treat lead poisoning with minimal or no side effects. This review has tried to summarize a few of the natural products/sources being investigated by various groups.

  10. Application of extraction-chromatographic concentration to atomic absorption determination of lead and cadmium in drinking and sea water

    International Nuclear Information System (INIS)

    Bol'shova, T.A.; Agapkina, G.I.; Ershova, N.I.; Narankho, K.E.

    1988-01-01

    To increase the detection limits for lead and cadmium atomic-absorption determination in natural waters methods of extraction-chromatographic concentration of these metals using tri-n-octylamine (TOA) on polytetrafluoroethylene (PTFE) is developed. Chromatograpy was carried out from 1.5-2.0 M HBr solutions. For cadmium and lead elution acetic acid was used. It is shown that extraction-chromatographic concentration permits to decrease limits of metal atomic-absorption detection by 10 3 with the 500 ml volume sample analysis

  11. Differential pulse anodic stripping voltametry for ultratrace determination of cadmium and lead in Antarctic snow

    International Nuclear Information System (INIS)

    Scarponi, G.; Barbante, C.; Cescon, P.

    1994-01-01

    Differential pulse anodic stripping voltametry has sufficient sensitivity to be used for direct determination of heavy metals in Antarctic snow, thus avoiding long and contamination-prone enrichment procedures. A result of particular concern to global change studies can be drawn from these preliminary data: lead concentration in Antarctic snow decreased rapidly during the 1980s from about 10-15 pg/g to 2-4 pg/g in 1991. (authors). 16 refs., 3 figs., 1 tab

  12. Direct Position Determination of Multiple Non-Circular Sources with a Moving Coprime Array

    Directory of Open Access Journals (Sweden)

    Yankui Zhang

    2018-05-01

    Full Text Available Direct position determination (DPD is currently a hot topic in wireless localization research as it is more accurate than traditional two-step positioning. However, current DPD algorithms are all based on uniform arrays, which have an insufficient degree of freedom and limited estimation accuracy. To improve the DPD accuracy, this paper introduces a coprime array to the position model of multiple non-circular sources with a moving array. To maximize the advantages of this coprime array, we reconstruct the covariance matrix by vectorization, apply a spatial smoothing technique, and converge the subspace data from each measuring position to establish the cost function. Finally, we obtain the position coordinates of the multiple non-circular sources. The complexity of the proposed method is computed and compared with that of other methods, and the Cramer–Rao lower bound of DPD for multiple sources with a moving coprime array, is derived. Theoretical analysis and simulation results show that the proposed algorithm is not only applicable to circular sources, but can also improve the positioning accuracy of non-circular sources. Compared with existing two-step positioning algorithms and DPD algorithms based on uniform linear arrays, the proposed technique offers a significant improvement in positioning accuracy with a slight increase in complexity.

  13. Direct Position Determination of Multiple Non-Circular Sources with a Moving Coprime Array.

    Science.gov (United States)

    Zhang, Yankui; Ba, Bin; Wang, Daming; Geng, Wei; Xu, Haiyun

    2018-05-08

    Direct position determination (DPD) is currently a hot topic in wireless localization research as it is more accurate than traditional two-step positioning. However, current DPD algorithms are all based on uniform arrays, which have an insufficient degree of freedom and limited estimation accuracy. To improve the DPD accuracy, this paper introduces a coprime array to the position model of multiple non-circular sources with a moving array. To maximize the advantages of this coprime array, we reconstruct the covariance matrix by vectorization, apply a spatial smoothing technique, and converge the subspace data from each measuring position to establish the cost function. Finally, we obtain the position coordinates of the multiple non-circular sources. The complexity of the proposed method is computed and compared with that of other methods, and the Cramer⁻Rao lower bound of DPD for multiple sources with a moving coprime array, is derived. Theoretical analysis and simulation results show that the proposed algorithm is not only applicable to circular sources, but can also improve the positioning accuracy of non-circular sources. Compared with existing two-step positioning algorithms and DPD algorithms based on uniform linear arrays, the proposed technique offers a significant improvement in positioning accuracy with a slight increase in complexity.

  14. Development and optimization of a nuclear method to determine the lead concentration as an ultra-trace element in ultra-pure water

    International Nuclear Information System (INIS)

    Amara, A.; Giovagnoli, A.; Barrandon, J.N.

    1994-01-01

    Here we intend to perfect a nuclear analytical technique for the determination of lead concentration as an ultra-trace element in ultra-pure water Inmost cases the analysis of an aqueous solution is made by non-nuclear methods, therefore methods which are sensitive to the chemical form of the element to be determined. To ovoid this problem we developed a nuclear technique using a cyclotron,which allows the determination of the lead concentration in any of its chemical forms. We studied the possibilities of several incident beams, like neutral particles and charged particles. Proton activation showed to be the most sensitive of all the irradiation procedures. Several points have though be studied and developed: - an irradiation cell for liquids irradiation under a strong proton current; - the bismuth chemical separation. This element has two radio-isotopes allowing the determination of lead;-optimize the experimental irradiation and measurements parameters in order to reach the lower detection limit. At last an intercomparison of several techniques has been made for different standards. It clearly showed that, contrary to atomic,potentiometric or mass spectrometry methods,only activation technique give accurate and reproducible results. (author).1 fig., 2 tabs., 4 refs

  15. Determination of lead in Smilax myosotiflora herbal preparations obtained in Malaysia.

    Science.gov (United States)

    Ang, H H; Lee, K L; Kiyoshi, M

    2004-08-01

    The DCA (Drug Control Authority), Malaysia implemented the phase 3 registration of traditional medicines on 1 January 1992 with special emphasis on the quality, efficacy and safety (including the presence of heavy metals) in all pharmaceutical dosage forms of traditional medicinal preparations. As such, a total of 100 traditional medicinal preparations, containing Smilax myosotiflora, in various pharmaceutical dosage forms, which were bought in the Malaysian market, were analysed for lead content using atomic absorption spectrophotometry. Results showed that 15% of the products analysed possessed 10.23-23.05 ppm of lead, and therefore, do not comply with the quality requirement for traditional medicines in Malaysia. The quality requirement for traditional medicines in Malaysia is that they should not exceed 10 ppm of lead. Out of these 15 products, five products exhibited 10.23-23.05 ppm of lead, in fact they have already been registered with the DCA Malaysia. However, the rest of the products, which possessed 12.24-20.72 ppm of lead, have still not been registered with the DCA Malaysia. Although this study successfully showed that only 85% of the products complied with the quality requirement for traditional medicines in Malaysia pertaining to lead, they cannot, however, be assumed to be safe from lead contamination because of batch-to-batch inconsistency.

  16. Mercury and Lead Levels in Common Soaps from Local Markets in Mashhad, Iran

    Directory of Open Access Journals (Sweden)

    Anahita Alizadeh

    2017-06-01

    Full Text Available Background: The potential toxicity of human exposure was investigated to heavy metals from diverse sources but few or none was on Iranian soaps. Hence, we aimed to determine the presence of lead and mercury in selected soaps commonly used in Mashhad, northeastern Iran. Methods: Different common brands of cosmetic, hygiene and contraband soaps were purchased from retail market of Mashhad in 2016. Levels of these metals were determined using atomic absorption spectroscopy technique. Results: All samples had the mercury and lead levels but did not exceed the maximum acceptable level (1 µg/g for mercury and 20 µg/g for lead recommended by FDA. The mean levels of mercury were 0.02, 0.08 and 0.23 µg/g, respectively in cosmetic, hygiene and contraband soaps. These levels for lead were 0.10, 0.19 and 0.13 µg/g. The highest mercury and lead levels were detected in Halazoon contraband and P hygiene brands, respectively. Conclusion: The content of mercury and lead in common soaps is currently not a concern in this city. However, as human body may be exposed to several toxic metals from different care products simultaneously, cumulative toxic effects of these metals must be considered important.

  17. Determining Sources of Fecal Contamination in Two Rivers of Northumberland County, Virginia

    OpenAIRE

    Szeles, Cheryl Lynne

    2003-01-01

    DETERMINING SOURCES OF FECAL CONTAMINATION IN TWO RIVERS OF NORTHUMBERLAND COUNTY, VIRGINIA By Cheryl Lynne Szeles Dr. Charles Hagedorn III, Chairman Crop and Soil Environmental Sciences (ABSTRACT) The goal of monitoring the water quality of shellfish beds is to provide protection against transmission of water-borne infectious diseases. The Coan River and the Little Wicomico River contain shellfish beds that are closed to harvest due to contamination with fecal ...

  18. Graphene oxide sheets immobilized polystyrene for column preconcentration and sensitive determination of lead by flame atomic absorption spectrometry.

    Science.gov (United States)

    Islam, Aminul; Ahmad, Hilal; Zaidi, Noushi; Kumar, Suneel

    2014-08-13

    A novel solid-phase extractant was synthesized by coupling graphene oxide (GO) on chloromethylated polystyrene through an ethylenediamine spacer unit to develop a column method for the preconcentration/separation of lead prior to its determination by flame atomic absorption spectrometry. It was characterized by Fourier transform infrared spectroscopy, far-infrared spectroscopy, thermogravimetric analysis/differential thermal analysis, scanning electron microscopy, energy-dispersive spectrometry, and transmission electron microscopy. The abundant oxygen-containing surface functional groups form a strong complex with lead, resulting in higher sorption capacity (227.92 mg g(-1)) than other nanosorbents used for sorption studies of the column method. Using the column procedure here is an alternative to the direct use of GO, which restricts irreversible aggregation of GO and its escape into the ecosystem, making it an environmentally sustainable method. The column method was optimized by varying experimental variables such as pH, flow rate for sorption/desorption, and elution condition and was observed to exhibit a high preconcentration factor (400) with a low preconcentration limit (2.5 ppb) and a high degree of tolerance for matrix ions. The accuracy of the proposed method was verified by determining the Pb content in the standard reference materials and by recovery experiments. The method showed good precision with a relative standard deviation <5%. The proposed method was successfully applied for the determination of lead in tap water, electroplating wastewater, river water, and food samples after preconcentration.

  19. Isotopic ratio method for determining uranium contamination

    International Nuclear Information System (INIS)

    Miles, R.E.; Sieben, A.K.

    1994-01-01

    The presence of high concentrations of uranium in the subsurface can be attributed either to contamination from uranium processing activities or to naturally occurring uranium. A mathematical method has been employed to evaluate the isotope ratios from subsurface soils at the Rocky Flats Nuclear Weapons Plant (RFP) and demonstrates conclusively that the soil contains uranium from a natural source and has not been contaminated with enriched uranium resulting from RFP releases. This paper describes the method used in this determination which has widespread application in site characterizations and can be adapted to other radioisotopes used in manufacturing industries. The determination of radioisotope source can lead to a reduction of the remediation effort

  20. The determination of major and some minor constituents in lead zirconate-titanate compositions by x-ray fluorescence and atomic absorption spectrometry

    NARCIS (Netherlands)

    van Willigen, J.H.H.G.; Kruidhof, H.; Dahmen, E.A.M.F.

    1972-01-01

    An accurate X-ray fluorescence spectrometric method is described for the determination of lead, zirconium and titanium in lead zirconate-titanate ceramics. Careful matching of samples and standards by a borax fusion method resulted in a relative standard deviation of about 0.2% for the major

  1. A lead isotopic study of the human bioaccessibility of lead in urban soils from Glasgow, Scotland

    Energy Technology Data Exchange (ETDEWEB)

    Farmer, John G., E-mail: J.G.Farmer@ed.ac.uk [School of GeoSciences, University of Edinburgh, Edinburgh, EH9 3JN, Scotland (United Kingdom); Broadway, Andrew [School of GeoSciences, University of Edinburgh, Edinburgh, EH9 3JN, Scotland (United Kingdom); Cave, Mark R.; Wragg, Joanna [British Geological Survey, Keyworth, Nottingham NG12 5GG, England (United Kingdom); Fordyce, Fiona M. [British Geological Survey, Edinburgh, EH9 3LA, Scotland (United Kingdom); Graham, Margaret C.; Ngwenya, Bryne T. [School of GeoSciences, University of Edinburgh, Edinburgh, EH9 3JN, Scotland (United Kingdom); Bewley, Richard J.F. [URS Corporation Ltd, Manchester, M1 6HS, England (United Kingdom)

    2011-11-01

    The human bioaccessibility of lead (Pb) in Pb-contaminated soils from the Glasgow area was determined by the Unified Bioaccessibility Research Group of Europe (BARGE) Method (UBM), an in vitro physiologically based extraction scheme that mimics the chemical environment of the human gastrointestinal system and contains both stomach and intestine compartments. For 27 soils ranging in total Pb concentration from 126 to 2160 mg kg{sup -1} (median 539 mg kg{sup -1}), bioaccessibility as determined by the 'stomach' simulation (pH {approx} 1.5) was 46-1580 mg kg{sup -1}, equivalent to 23-77% (mean 52%) of soil total Pb concentration. The corresponding bioaccessibility data for the 'stomach + intestine' simulation (pH {approx} 6.3) were 6-623 mg kg{sup -1} and 2-42% (mean 22%) of soil Pb concentration. The soil {sup 206}Pb/{sup 207}Pb ratios ranged from 1.057 to 1.175. Three-isotope plots of {sup 208}Pb/{sup 206}Pb against {sup 206}Pb/{sup 207}Pb demonstrated that {sup 206}Pb/{sup 207}Pb ratios were intermediate between values for source end-member extremes of imported Australian Pb ore (1.04) - used in the manufacture of alkyl Pb compounds (1.06-1.10) formerly added to petrol - and indigenous Pb ores/coal (1.17-1.19). The {sup 206}Pb/{sup 207}Pb ratios of the UBM 'stomach' extracts were similar (< 0.01 difference) to those of the soil for 26 of the 27 samples (r = 0.993, p < 0.001) and lower in 24 of them. A slight preference for lower {sup 206}Pb/{sup 207}Pb ratio was discernible in the UBM. However, the source of Pb appeared to be less important in determining the extent of UBM-bioaccessible Pb than the overall soil total Pb concentration and the soil phases with which the Pb was associated. The significant phases identified in a subset of samples were carbonates, manganese oxides, iron-aluminium oxyhydroxides and clays. - Highlights: {yields} We determined the human bioaccessibility of Pb in urban soils by in vitro extraction. {yields} We

  2. Gammatography of thick lead vessels

    International Nuclear Information System (INIS)

    Raghunath, V.M.; Bhatnagar, P.K.; Sundaram, V.M.

    1979-01-01

    Radiography, scintillation and GM counting and dose measurements using ionisation chamber equipment are commonly used for detecting flaws/voids in materials. The first method is mostly used for steel vessels and to a lesser extent thin lead vessels also and is essentially qualitative. Dose measuring techniques are used for very thick and large lead vessels for which high strength radioactive sources are required, with its inherent handling problems. For vessels of intermediate thicknesses, it is ideal to use a small strength source and a GM or scintillation counter assembly. At the Reactor Research Centre, Kalpakkam, such a system was used for checking three lead vessels of thicknesses varying from 38mm to 65mm. The tolerances specified were +- 4% variation in lead thickness. The measurements also revealed the non concentricity of one vessel which had a thickness varying from 38mm to 44mm. The second vessel was patently non-concentric and the dimensional variation was truly reproduced in the measurements. A third vessel was fabricated with careful control of dimensions and the measurements exhibited good concentricity. Small deviations were observed, attributable to imperfect bondings between steel and lead. This technique has the following advantages: (a) weaker sources used result in less handling problems reducing the personnel exposures considerably; (b) the sensitivity of the instrument is quite good because of better statistics; (c) the time required for scanning a small vessel is more, but a judicious use of a scintillometer for initial fast scan will help in reducing the total scanning time; (d) this method can take advantage of the dimensional variations themselves to get the calibration and to estimate the deviations from specified tolerances. (auth.)

  3. Combination of flame atomic absorption spectrometry with ligandless-dispersive liquid- liquid microextraction for preconcentration and determination of trace amount of lead in water samples

    Directory of Open Access Journals (Sweden)

    Y.M. Baghelani

    2013-05-01

    Full Text Available A new ligandless-dispersive liquid–liquid microextraction method has been developed for the separation and flame atomic absorption spectrometry determination of trace amount of lead(II ion. In the proposed approach 1,2-dicholorobenzene and ethanol were used as extraction and dispersive solvents. Factors influencing the extraction efficiency of lead, including the extraction and dispersive solvent type and volume, pH of sample solution, concentration of chloride and extraction time were studied. Under the optimal conditions, the calibration curve was linear in the range of 7.0–6000 ng mL−1 of lead with R2 = 0.9992 (n = 10 and detection limit based on three times the standard deviation of the blank (3Sb was 0.5 ng mL−1 in original solution. The relative standard deviation for eight replicate determinations of 1.0 mg mL-1 lead was ±1.6%. The high efficiency of dispersive liquid-liquid microextraction to carry out the determination of trace amounts of lead in complex matrices was demonstrated. The proposed method has been applied for determination of trace amounts of lead in water samples and satisfactory results were obtained. The accuracy was checked by analyzing a certified reference material from the National Institute of Standard and Technology, Trace elements in water (NIST CRM 1643e.

  4. Exposure to lead from intake of coffee

    DEFF Research Database (Denmark)

    Hansen, Max; Sloth, Jens Jørgen; Rasmussen, Rie Romme

    Food and beverages is one of the primary sources of intake of and exposure to lead, with beverages accounting for almost 50%. Previous studies from Denmark have estimated that the intake of lead from coffee is very high and may contribute to up to 20% of the total lead intake from food and bevera......Food and beverages is one of the primary sources of intake of and exposure to lead, with beverages accounting for almost 50%. Previous studies from Denmark have estimated that the intake of lead from coffee is very high and may contribute to up to 20% of the total lead intake from food...... and beverages. This estimate is, however, based on older, non-published data. In the current project extensive chemical analyses of coffee beans, drinking water and ready-to-drink coffee have been performed. The results hereof have been compared to calculations of the total intake of lead from food...... and beverages. The results show that the intake of lead from coffee is considerably lower than previously estimated and account for 4.2% and 3.3% of the total lead intake from food and beverages for Danish men and women, respectively. It can generally be concluded that the intake of lead from coffee is low...

  5. Monte Carlo study of a flexible device for in situ PGNAA using 241Am-Be source: application to total chlorine determination

    International Nuclear Information System (INIS)

    Khelifi, R.; Bode, P.

    2016-01-01

    MCNP5 has been used to optimize the design of a Prompt gamma ray neutron activation analysis (PGNAA) facility, which was subsequently constructed for quantification of total chlorine in water to simulate neutron transport from an 241 AmBe source into a PGNAA set-up. Modeling calculations were performed to optimize the experimental set-up for Cl measurements in water. The optimization with MCNP5 was focused on maximizing the thermal neutrons flux which leads to improving the gamma prompt production after neutron capture in a water sample. The influence of dimensions and materials for the neutron collimation as well as the dimensions of the sample together were studied. A PGNAA facility with an 241 AmBe neutron source was built based on the optimized configuration and used to determine chlorine concentration. Measured values of the chlorine count rate were plotted versus the NaCl in water. The count rate versus amount of chlorine show a good coefficient of correlation of the linear fit. The result permits PGNAA to be a valuable diagnostic tool for getting an indication of the salinity contamination of water. (author)

  6. Determination of sources and analysis of micro-pollutants in drinking water

    International Nuclear Information System (INIS)

    Md Pauzi Abdullah; Soh Shiau Chian

    2005-01-01

    The objectives of the study are to develop and validate selected analytical methods for the analysis of micro organics and metals in water; to identify, monitor and assess the levels of micro organics and metals in drinking water supplies; to evaluate the relevancy of the guidelines set in the National Standard of Drinking Water Quality 2001; and to identify the sources of pollution and to carryout risk assessment of exposure to drinking water. The presentation discussed the progress of the work include determination of VOCs (Volatile organic compounds) in drinking water using SPME (Solid phase micro-extraction) extraction techniques, analysis of heavy metals in drinking water, determination of Cr(VI) with ICPES (Inductively coupled plasma emission spectrometry) and the presence of halogenated volatile organic compounds (HVOCs), which is heavily used by agricultural sector, in trace concentrations in waters

  7. NEAR REAL-TIME DETERMINATION OF EARTHQUAKE SOURCE PARAMETERS FOR TSUNAMI EARLY WARNING FROM GEODETIC OBSERVATIONS

    Directory of Open Access Journals (Sweden)

    S. Manneela

    2016-06-01

    Full Text Available Exemplifying the tsunami source immediately after an earthquake is the most critical component of tsunami early warning, as not every earthquake generates a tsunami. After a major under sea earthquake, it is very important to determine whether or not it has actually triggered the deadly wave. The near real-time observations from near field networks such as strong motion and Global Positioning System (GPS allows rapid determination of fault geometry. Here we present a complete processing chain of Indian Tsunami Early Warning System (ITEWS, starting from acquisition of geodetic raw data, processing, inversion and simulating the situation as it would be at warning center during any major earthquake. We determine the earthquake moment magnitude and generate the centroid moment tensor solution using a novel approach which are the key elements for tsunami early warning. Though the well established seismic monitoring network, numerical modeling and dissemination system are currently capable to provide tsunami warnings to most of the countries in and around the Indian Ocean, the study highlights the critical role of geodetic observations in determination of tsunami source for high-quality forecasting.

  8. Exploring the uncertainty in attributing sediment contributions in fingerprinting studies due to uncertainty in determining element concentrations in source areas.

    Science.gov (United States)

    Gomez, Jose Alfonso; Owens, Phillip N.; Koiter, Alex J.; Lobb, David

    2016-04-01

    determine an average value for each of the different maps of element concentration and sub-catchment, under different sampling densities: 200 different average values for the "high" sampling density (average of 50 samples); 400 different average values for the "medium" sampling density (average of 25 samples); and 1,000 different average values for the "low" sampling density (average of 10 samples). All these combinations of possible values of element concentrations in the source areas were solved for the concentration in the sediment already determined for the "true" solution using limSolve (Soetaert et al., 2014) in R language. The sediment source solutions found for the different situations and values were analyzed in order to: 1) evaluate the uncertainty in the sediment source attribution; and 2) explore strategies to detect the most probable solutions that might lead to improved methods for constructing the most robust mixing models. Preliminary results on these will be presented and discussed in this communication. Key words: sediment, fingerprinting, uncertainty, variability, mixing model. References Collins, A.L., Zhang, Y., McChesney, D., Walling, D.E., Haley, S.M., Smith, P. 2012. Sediment source tracing in a lowland agricultural catchment in southern England using a modified procedure combining statistical analysis and numerical modelling. Science of the Total Environment 414: 301-317. Freeze, R.A. 1980. A stochastic-conceptual analysis of rainfall-runoff processes on a hillslope. Water Resources Research 16: 391-408.

  9. A next-to-leading determination of the singlet axial charge and the polarized gluon content of the nucleon

    CERN Document Server

    Ball, R D; Ridolfi, G

    1996-01-01

    We perform a full next-to-leading analysis of the the available experimental data on the polarized structure function g_1 of the nucleon, and give a precise determination of its singlet axial charge together with a thorough assessment of the theoretical uncertainties. We find that the data are now sufficient to separately determine first moments of the polarized quark and gluon distributions and show in particular that the gluon contribution is large and positive.

  10. Determination of silicon in biomass and products of pyrolysis process via high-resolution continuum source atomic absorption spectrometry.

    Science.gov (United States)

    Nakadi, Flávio V; Prodanov, Caroline; Boschetti, Wiliam; Vale, Maria Goreti R; Welz, Bernhard; de Andrade, Jailson B

    2018-03-01

    Thermochemical processes can convert the biomass into fuels, such as bio-oil. The biomass submitted to pyrolysis process, such as fibers, are generally rich in silicon, an element that can lead to damages in an engine when there is high concentration in a fuel. High-resolution continuum source atomic absorption spectrometry (HR-CS AAS) is an interesting alternative for Si determination in the products and byproducts of the pyrolysis process because, besides the flame (F) and graphite furnace (GF) atomizers, it has enhanced the application of direct analysis of solid samples (SS) within GF. This study aimed the development of methods to determine Si in biomass samples, their products and byproducts using HR-CS AAS. A high-resolution continuum source atomic absorption spectrometer contrAA 700 equipped with F and GF atomizers was used throughout the study. HR-CS F AAS (λ = 251.611nm, 1 detection pixel, N 2 O/C 2 H 2 flame) was used to evaluate Si content in biomass and ash, after a microwave-assisted acid digestion with HNO 3 and HF. HR-CS GF AAS (T pyr = 1400°C, T atom = 2650°C) has evaluated Si in pyrolysis water and bio-oil at 251.611nm, and in peach pit biomass and ash at 221.174nm using SS, both wavelengths with 1 detection pixel. Rhodium (300μg) was applied as permanent modifier and 10μgPd + 6μg Mg were pipetted onto the standards/samples at each analysis. Three different biomass samples were studied: palm tree fiber, coconut fiber and peach pit, and three certified reference materials (CRM) were used to verify the accuracy of the methods. The figures of merit were LOD 0.09-20mgkg -1 , and LOQ 0.3-20mgkg -1 , considering all the methods. There were no significant differences between the CRM certified values and the determined ones, using a Student t-test with a confidence interval of 95% (n = 5). Si concentration ranged from 0.11-0.92% mm -1 , 1.1-1.7mgkg -1 , 3.3-13mgkg -1 , and 0.41-1.4%mm -1 , in biomass, bio-oil, pyrolysis water and ash, respectively

  11. Next-To-Leading Order Determination of Fragmentation Functions

    CERN Document Server

    Bourhis, L; Guillet, J P; Werlen, M

    2001-01-01

    We analyse LEP and PETRA data on single inclusive charged hadron cross-sections to establish new sets of Next-to-Leading order Fragmentation Functions. Data on hadro-production of large-$p_{\\bot}$ hadrons are also used to constrain the gluon Fragmentation Function. We carry out a critical comparison with other NLO parametrizations.

  12. Impact of Next-to-Leading Order Contributions to Cosmic Microwave Background Lensing.

    Science.gov (United States)

    Marozzi, Giovanni; Fanizza, Giuseppe; Di Dio, Enea; Durrer, Ruth

    2017-05-26

    In this Letter we study the impact on cosmological parameter estimation, from present and future surveys, due to lensing corrections on cosmic microwave background temperature and polarization anisotropies beyond leading order. In particular, we show how post-Born corrections, large-scale structure effects, and the correction due to the change in the polarization direction between the emission at the source and the detection at the observer are non-negligible in the determination of the polarization spectra. They have to be taken into account for an accurate estimation of cosmological parameters sensitive to or even based on these spectra. We study in detail the impact of higher order lensing on the determination of the tensor-to-scalar ratio r and on the estimation of the effective number of relativistic species N_{eff}. We find that neglecting higher order lensing terms can lead to misinterpreting these corrections as a primordial tensor-to-scalar ratio of about O(10^{-3}). Furthermore, it leads to a shift of the parameter N_{eff} by nearly 2σ considering the level of accuracy aimed by future S4 surveys.

  13. 40 CFR 60.372 - Standards for lead.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 6 2010-07-01 2010-07-01 false Standards for lead. 60.372 Section 60...) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Lead-Acid Battery Manufacturing Plants § 60.372 Standards for lead. (a) On and after the date on which the performance test...

  14. 40 CFR 52.1681 - Control strategy: Lead.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 4 2010-07-01 2010-07-01 false Control strategy: Lead. 52.1681 Section...) APPROVAL AND PROMULGATION OF IMPLEMENTATION PLANS (CONTINUED) New York § 52.1681 Control strategy: Lead. As part of the attainment demonstration for lead, the State of New York has committed to rate all sources...

  15. Determination of Original Infection Source of H7N9 Avian Influenza by Dynamical Model

    Science.gov (United States)

    Zhang, Juan; Jin, Zhen; Sun, Gui-Quan; Sun, Xiang-Dong; Wang, You-Ming; Huang, Baoxu

    2014-05-01

    H7N9, a newly emerging virus in China, travels among poultry and human. Although H7N9 has not aroused massive outbreaks, recurrence in the second half of 2013 makes it essential to control the spread. It is believed that the most effective control measure is to locate the original infection source and cut off the source of infection from human. However, the original infection source and the internal transmission mechanism of the new virus are not totally clear. In order to determine the original infection source of H7N9, we establish a dynamical model with migratory bird, resident bird, domestic poultry and human population, and view migratory bird, resident bird, domestic poultry as original infection source respectively to fit the true dynamics during the 2013 pandemic. By comparing the date fitting results and corresponding Akaike Information Criterion (AIC) values, we conclude that migrant birds are most likely the original infection source. In addition, we obtain the basic reproduction number in poultry and carry out sensitivity analysis of some parameters.

  16. Gravitation and source theory

    International Nuclear Information System (INIS)

    Yilmaz, H.

    1975-01-01

    Schwinger's source theory is applied to the problem of gravitation and its quantization. It is shown that within the framework of a flat-space the source theory implementation leads to a violation of probability. To avoid the difficulty one must introduce a curved space-time hence the source concept may be said to necessitate the transition to a curved-space theory of gravitation. It is further shown that the curved-space theory of gravitation implied by the source theory is not equivalent to the conventional Einstein theory. The source concept leads to a different theory where the gravitational field has a stress-energy tensor t/sup nu//sub mu/ which contributes to geometric curvatures

  17. Experimental determination of dosimetric characterization of a newly designed encapsulated interstitial brachytherapy source of 103Pd-model Pd-1

    International Nuclear Information System (INIS)

    Nath, Ravinder; Yue Ning; Roa, Eduardo

    2002-01-01

    A newly designed encapsulated 103 Pd source has been introduced (BrachySeed trade mark sign -Pd-103, also named Model Pd-1, manufactured by DRAXIMAGE Inc. and distributed by Cytogen Corp.) for interstitial brachytherapy to provide more isotropic dose distributions. In this work, the dosimetric characteristics of the 103 Pd source were measured with micro LiF TLD chips and dosimetry parameters were characterized based upon the American Association of Physicists in Medicine (AAPM) Task Group No. 43 formalism. The dose rate constant of the sources was determined to be 0.66±0.05 cGy h-1 U-1. The radial dose function was measured and was found to be similar to that of the Theragenics Model 200 103 Pd source. The anisotropy constant for the Model Pd-1 source was determined to be 1.03

  18. Environmental lead exposure risks associated with children's outdoor playgrounds

    International Nuclear Information System (INIS)

    Taylor, Mark Patrick; Camenzuli, Danielle; Kristensen, Louise Jane; Forbes, Miriam; Zahran, Sammy

    2013-01-01

    This study examines exposure risks associated with lead smelter emissions at children's public playgrounds in Port Pirie, South Australia. Lead and other metal values were measured in air, soil, surface dust and on pre- and post-play hand wipes. Playgrounds closest to the smelter were significantly more lead contaminated compared to those further away (t(27.545) = 3.76; p = .001). Port Pirie post-play hand wipes contained significantly higher lead loadings (maximum hand lead value of 49,432 μg/m 2 ) than pre-play hand wipes (t(27) = 3.57, p = .001). A 1% increase in air lead (μg/m 3 ) was related to a 0.713% increase in lead dust on play surfaces (95% CI, 0.253–1.174), and a 0.612% increase in post-play wipe lead (95% CI, 0.257–0.970). Contaminated dust from smelter emissions is determined as the source and cause of childhood lead poisoning at a rate of approximately one child every third day. -- Highlights: •Spatial and temporal variations in lead exposure due to smelter emissions is examined. •Exposure to lead and other metals is evaluated using pre and post-play hand wipe measures. •The relationship of smelter emissions to surface and hand lead exposures is modelled. •A 1% increase in air lead (μg/m 3 ) was related to a 0.713% increase in lead dust on play surfaces. -- Playgrounds in Port Pirie are seriously contaminated by smelter emissions, with levels of surface dust and hand dust that pose a significant risk of harm to human health

  19. Products and stability of phosphate reactions with lead under freeze-thaw cycling in simple systems

    Energy Technology Data Exchange (ETDEWEB)

    Hafsteinsdottir, Erla G., E-mail: erla.hafsteinsdottir@gmail.com [Department of Environment and Geography, Macquarie University, NSW 2109 (Australia); White, Duanne A., E-mail: duanne.white@mq.edu.au [Department of Environment and Geography, Macquarie University, NSW 2109 (Australia); Gore, Damian B., E-mail: damian.gore@mq.edu.au [Department of Environment and Geography, Macquarie University, NSW 2109 (Australia); Stark, Scott C., E-mail: scott.stark@aad.gov.au [Environmental Protection and Change, Australian Antarctic Division, Department of Sustainability, Environment, Water, Population and Communities, Tasmania 7050 (Australia)

    2011-12-15

    Orthophosphate fixation of metal contaminated soils in environments that undergo freeze-thaw cycles is understudied. Freeze-thaw cycling potentially influences the reaction rate, mineral chemical stability and physical breakdown of particles during fixation. This study determines what products form when phosphate (triple superphosphate [Ca(H{sub 2}PO{sub 4}){sub 2}] or sodium phosphate [Na{sub 3}PO{sub 4}]) reacts with lead (PbSO{sub 4} or PbCl{sub 2}) in simple chemical systems in vitro, and assesses potential changes in formation during freeze-thaw cycles. Systems were subjected to multiple freeze-thaw cycles from +10 deg. C to -20 deg. C and then analysed by X-ray diffractometry. Pyromorphite formed in all systems and was stable over multiple freeze-thaw cycles. Low temperature lead orthophosphate reaction efficiency varied according to both phosphate and lead source; the most time-efficient pyromorphite formation was observed when PbSO{sub 4} and Na{sub 3}PO{sub 4} were present together. These findings have implications for the manner in which metal contaminated materials in freezing ground can be treated with phosphate. - Highlights: > Formation of lead phosphate products in cold environments is identified. > Potential change in formation during freeze-thaw cycling is assessed. > Lead phosphate reaction efficiency varies according to phosphate and lead source. > Pyromorphite formation is stable during 240 freeze-thaw cycles. - Pyromorphite, formed from Pb phosphate fixation, is stable during multiple freeze-thaw cycles but the efficiency of the fixation depends on the phosphate source and the type of Pb mineral.

  20. Stucture and development of the secondary lead capacity

    Energy Technology Data Exchange (ETDEWEB)

    Baack, T [Metallgesellschaft A.G., Frankfurt am Main (Germany, F.R.)

    1978-05-01

    Lead is considered to be one of the 'finite' raw materials, but in the form it is normally used, it can almost be infinitely recycled. Lead wastes and lead scrap are in a way secondary sources which continuously regenerate. The regeneration power of lead has a leading position among non-precious metals. The reasons behind the capability to regenerate lead and future developments are discussed.

  1. Identification of historical lead sources in roof dust and recent lake sediments from an industrialized are: Indications from lead isotopes

    International Nuclear Information System (INIS)

    Chenhall, B.E.; Depers, A.M.; Jones, B.G.; Chiaradia, M.

    1997-01-01

    X-ray fluorescence and stable lead (Pb) isotopic analyses have been undertaken on dusts, known from microscopic investigation to contain significant quantities of industrially- and urban-derived particulate matter, present in the roof cavities of houses in the Illawarra region (N.S.W., Australia), with the objective of examining the historic record of Pb pollution. All investigated houses contained in excess of 250 μg g -1 Pb, with dwellings close to a copper smelter, in a large industrial complex including a major steelworks, containing higher (>2500 μg g -1 ) Pb concentrations. The isotopic composition in the dusts, expressed here as 206 Pb/ 204 Pb, is relatively constant at 17.0, irrespective of dwelling age or distance from the industrial complex. Contamination of the dusts by Pb sourced from paint cannot explain the isotopic uniformity of the dust samples. Isotopic modelling indicates that the dusts contain Pb derived from the copper smelter, gasoline-air Pb and a minor contribution from the steelworks. Isotopic calculations, together with records of particulate pollution emission, indicate a link between the Pb in roof dusts and Pb contamination of the near surface lagoonal sediments. Over the last five decades, atmospheric fallout of Pb-bearing particulate matter appears to have been the dominant pathway for addition of Pb to the lagoon and dwellings in the Illawarra region

  2. Determination of combustible volatile matter in coal mine roadway dusts by backscatter of x-rays from a radioisotope source

    International Nuclear Information System (INIS)

    Ailwood, C.R.; Bunch, K.; Fookes, R.A.; Gravitis, V.L.; Watt, J.S.

    1977-01-01

    The combustible volatile matter in coal mine roadway dusts (CVM) has been determined using x-ray backscatter techniques. The correlation between x-ray and chemical techniques is reasonably good for the 92 samples from collieries on the Bulli seam, and the maximum error expected at the maximum level of 11.5 weight per cent CVM permitted in the N.S.W. Coal Mines Regulation Act, 1912, as amended, is about +- 2.5 weight per cent. This x-ray technique can be used only when the combustible volatile content of the coal matter (CVM) varies within a limited range, and a separate calibration is required for each coal seam. Portable equipment based on a radioisotope x-ray source and digital ratemeter makes possible simple and rapid analysis, and with adaptation to use in coal mines should lead to much more comprehensive testing of roadways and hence improved overall prevention of coal dust explosions. (author)

  3. Leading-order determination of the gluon polarisation from semi-inclusive deep inelastic scattering data

    CERN Document Server

    Adolph, C.; Akhunzyanov, R.; Alexeev, M.G.; Alexeev, G.D.; Amoroso, A.; Andrieux, V.; Anfimov, N.V.; Anosov, V.; Augustyniak, W.; Austregesilo, A.; Azevedo, C.D.R.; Badelek, B.; Balestra, F.; Barth, J.; Beck, R.; Bedfer, Y.; Bernhard, J.; Bicker, K.; Bielert, E.R.; Birsa, R.; Bisplinghoff, J.; Bodlak, M.; Boer, M.; Bordalo, P.; Bradamante, F.; Braun, C.; Bressan, A.; Buchele, M.; Chang, W.C.; Chiosso, M.; Choi, I.; Chung, S.U.; Cicuttin, A.; Crespo, M.L.; Curiel, Q.; Dalla Torre, S.; Dasgupta, S.S.; Dasgupta, S.; Denisov, O.Yu.; Dhara, L.; Donskov, S.V.; Doshita, N.; Duic, V.; Dunnweber, W.; Dziewiecki, M.; Efremov, A.; Eversheim, P.D.; Eyrich, W.; Faessler, M.; Ferrero, A.; Finger, M.; M. Finger jr; Fischer, H.; Franco, C.; von Hohenesche, N. du Fresne; Friedrich, J.M.; Frolov, V.; Fuchey, E.; Gautheron, F.; Gavrichtchouk, O.P.; Gerassimov, S.; Giordano, F.; Gnesi, I.; Gorzellik, M.; Grabmuller, S.; Grasso, A.; Grosse Perdekamp, M.; Grube, B.; Grussenmeyer, T.; Guskov, A.; Haas, F.; Hahne, D.; von Harrach, D.; Hashimoto, R.; Heinsius, F.H.; Heitz, R.; Herrmann, F.; Hinterberger, F.; Horikawa, N.; d'Hose, N.; Hsieh, C.Y.; Huber, S.; Ishimoto, S.; Ivanov, A.; Ivanshin, Yu.; Iwata, T.; Jahn, R.; Jary, V.; Joosten, R.; Jorg, P.; Kabuss, E.; Ketzer, B.; Khaustov, G.V.; Khokhlov, Yu. A.; Kisselev, Yu.; Klein, F.; Klimaszewski, K.; Koivuniemi, J.H.; Kolosov, V.N.; Kondo, K.; Konigsmann, K.; Konorov, I.; Konstantinov, V.F.; Kotzinian, A.M.; Kouznetsov, O.M.; Kramer, M.; Kremser, P.; Krinner, F.; Kroumchtein, Z.V.; Kulinich, Y.; Kunne, F.; Kurek, K.; Kurjata, R.P.; Lednev, A.A.; Lehmann, A.; Levillain, M.; Levorato, S.; Lichtenstadt, J.; Longo, R.; Maggiora, A.; Magnon, A.; Makins, N.; Makke, N.; Mallot, G.K.; Marchand, C.; Marianski, B.; Martin, A.; Marzec, J.; J.Matou s; Matsuda, H.; Matsuda, T.; Meshcheryakov, G.V.; Meyer, W.; Michigami, T.; Mikhailov, Yu. V.; Mikhasenko, M.; Miyachi, Y.; Montuenga, P.; Nagaytsev, A.; Nerling, F.; Neyret, D.; Nikolaenko, V.I.; Novy, J.; Nowak, W.D.; Nukazuka, G.; Nunes, A.S.; Olshevsky, A.G.; Orlov, I.; Ostrick, M.; Panzieri, D.; Parsamyan, B.; Paul, S.; Peng, J.C.; Pereira, F.; M. Pe s; Peshekhonov, D.V.; Platchkov, S.; Pochodzalla, J.; Polyakov, V.A.; Pretz, J.; Quaresma, M.; Quintans, C.; Ramos, S.; Regali, C.; Reicherz, G.; Riedl, C.; Roskot, M.; Rossiyskaya, N.S.; Ryabchikov, D.I.; Rybnikov, A.; Rychter, A.; Salac, R.; Samoylenko, V.D.; Sandacz, A.; Santos, C.; Sarkar, S.; Savin, I.A.; Sawada, T.; Sbrizzai, G.; Schiavon, P.; Schmidt, K.; Schmieden, H.; Schonning, K.; Schopferer, S.; Seder, E.; Selyunin, A.; Shevchenko, O.Yu.; Silva, L.; Sinha, L.; Sirtl, S.; Slunecka, M.; Smolik, J.; Sozzi, F.; Srnka, A.; Stolarski, M.; Sulc, M.; Suzuki, H.; Szabelski, A.; Szameitat, T.; Sznajder, P.; Takekawa, S.; Tasevsky, M.; Tessaro, S.; Tessarotto, F.; Thibaud, F.; Tosello, F.; Tskhay, V.; Uhl, S.; Veloso, J.; Virius, M.; Vondra, J.; Weisrock, T.; Wilfert, M.; Wolbeek, J. ter; Zaremba, K.; Zavada, P.; Zavertyaev, M.; Zemlyanichkina, E.; Ziembicki, M.; Zink, A.

    2017-01-01

    Using a novel analysis technique, the gluon polarisation in the nucleon is re-evaluated using the longitudinal double-spin asymmetry measured in the cross section of semi-inclusive single-hadron muoproduction with photon virtuality $Q^2>1~({\\rm GeV}/c)^2$. The data were obtained by the COMPASS experiment at CERN using a 160 GeV/$c$ polarised muon beam impinging on a polarised $^6$LiD target. By analysing the full range in hadron transverse momentum $p_T$, the different $p_T$-dependences of the underlying processes are separated using a neural-network approach. In the absence of pQCD calculations at next-to-leading order in the selected kinematic domain, the gluon polarisation $\\Delta g/g$ is evaluated at leading order in pQCD at a hard scale of $\\mu^2 = \\langle Q^2\\rangle = 3(GeV=c)^2$. It is determined in three intervals of the nucleon momentum fraction carried by gluons, $x_g$, covering the range $0.04 \\!<\\! x_{ \\rm g}\\! <\\! 0.28$ . and does not exhibit a significant dependence on $x_{\\rm g}$. Average...

  4. Development of the methodology for estimation of dose from a source

    International Nuclear Information System (INIS)

    Golebaone, E.M.

    2012-04-01

    The geometry of a source plays an important role when determining which method to apply in order to accurately estimate dose from a source. If wrong source geometry is used the dose received may be underestimated or overestimated therefore this may lead to wrong decision in dealing with the exposure situation. In this project moisture density gauge was used to represent a point source in order to demonstrate the key parameters to be used when estimating dose from point source. The parameters to be considered are activity of the source, the ambient dose rate, gamma constant for the radionuclide, as well as the transport index on the package of the source. The distance from the source, and the time spent in the radiation field must be known in order to calculate the dose. (author)

  5. Biosorption of lead phosphates by lead-tolerant bacteria as a mechanism for lead immobilization.

    Science.gov (United States)

    Rodríguez-Sánchez, Viridiana; Guzmán-Moreno, Jesús; Rodríguez-González, Vicente; Flores-de la Torre, Juan Armando; Ramírez-Santoyo, Rosa María; Vidales-Rodríguez, Luz Elena

    2017-08-01

    The study of metal-tolerant bacteria is important for bioremediation of contaminated environments and development of green technologies for material synthesis due to their potential to transform toxic metal ions into less toxic compounds by mechanisms such as reduction, oxidation and/or sequestration. In this study, we report the isolation of seven lead-tolerant bacteria from a metal-contaminated site at Zacatecas, México. The bacteria were identified as members of the Staphylococcus and Bacillus genera by microscopic, biochemical and 16S rDNA analyses. Minimal inhibitory concentration of these isolates was established between 4.5 and 7.0 mM of Pb(NO 3 ) 2 in solid and 1.0-4.0 mM of Pb(NO 3 ) 2 in liquid media. A quantitative analysis of the lead associated to bacterial biomass in growing cultures, revealed that the percentage of lead associated to biomass was between 1 and 37% in the PbT isolates. A mechanism of complexation/biosorption of lead ions as inorganic phosphates (lead hydroxyapatite and pyromorphite) in bacterial biomass, was determined by Fourier transform infrared spectroscopy and X-ray diffraction analyses. Thus, the ability of the lead-tolerant isolates to transform lead ions into stable and highly insoluble lead minerals make them potentially useful for immobilization of lead in mining waste.

  6. Feasibility study for the in vivo measurement of lead in bone using L-x-ray fluorescence

    International Nuclear Information System (INIS)

    Wielopolski, L.; Slatkin, D.N.; Vartsky, D.; Ellis, K.J.; Cohn, S.H.

    1980-01-01

    Lead deposits in bone were detected by x-ray fluorescence using x-rays from either a 125 I or a 109 Cd source. Measurements were taken from tibia in intact human legs, post-mortem. On the basis of preliminary measurements, it was concluded that an exposure of one rad is adequate for determination of lead in bone. Both the advantages and the disadvantages of L-x-rays, used in the technique developed for this study, are compared with those of K-x-rays

  7. Lead poisoning in Australian fruit bats (Pteropus poliocephalus)

    Energy Technology Data Exchange (ETDEWEB)

    Zook, B.C.; Sauer, R.M.; Garner, F.M.

    1970-09-01

    Lead poisoning was diagnosed in 3 Australian fruit bats. Diagnoses were indicated by the finding of large acid-fast intranuclear inclusion bodies in renal and hepatic cells, and toxic amounts of lead in tissues. The source of lead was believed to be peeling leaded paint from the walls of the bats' cage.

  8. Australian atmospheric lead deposition reconstructed using lead concentrations and isotopic compositions of archival lichen and fungi

    International Nuclear Information System (INIS)

    Wu, Liqin; Taylor, Mark Patrick; Handley, Heather K.; Wu, Michael

    2016-01-01

    Lead concentrations and their isotopic compositions were measured in lichen genera Cladonia and Usnea and fungi genus Trametes from the Greater Sydney region (New South Wales, Australia) that had been collected and archived over the past 120 years. The median lead concentrations were elevated in lichens and fungi prior to the introduction of leaded petrol (Cladonia 12.5 mg/kg; Usnea 15.6 mg/kg; Trametes 1.85 mg/kg) corresponding to early industrial development. During the period of leaded petrol use in Australian automobiles from 1932 to 2002, total median lead concentrations rose: Cladonia 18.8 mg/kg; Usnea 21.5 mg/kg; Trametes 4.3 mg/kg. Following the cessation of leaded petrol use, median total lead concentrations decreased sharply in the 2000s: Cladonia 4.8 mg/kg; Usnea 1.7 mg/kg. The lichen and fungi isotopic compositions reveal a significant decrease in "2"0"6Pb/"2"0"7Pb ratios from the end of 19th century to the 1970s. The following decades were characterised by lower allowable levels of lead additive in fuel and the introduction of unleaded petrol in 1985. The environmental response to these regulatory changes was that lichen and fungi "2"0"6Pb/"2"0"7Pb ratios increased, particularly from 1995 onwards. Although the lead isotope ratios of lichens continued to increase in the 2000s they do not return to pre-leaded petrol values. This demonstrates that historic leaded petrol emissions, inter alia other sources, remain a persistent source of anthropogenic contamination in the Greater Sydney region. - Highlights: • Total lead and isotopic composition can be measured in historic lichen and fungi. • Historic lichen and fungi samples can distinguish polluted and unpolluted areas. • Former leaded petrol depositions remain a significant environmental contaminant. - Analysis of a 120-year record of lichens and fungi from the Greater Sydney basin reveal marked shifts in total lead concentrations and lead isotope ratios in response to geogenic inputs

  9. Radiochemical determination of radium-226, radium-228 and lead-210 in the Rimac River waters; Determinacion radioquimica de radio-226, radio-228 y plomo-210 en aguas del rio Rimac

    Energy Technology Data Exchange (ETDEWEB)

    De Lama, G; Osores, J [Instituto Peruano de Energia Nuclear, Lima (Peru). Departamento de Control Ambiental

    2002-07-01

    The main objective of this research was quantification of Ra-226, Ra-228 and Pb-210 at the Rimac River, main source of water supply for Lima's population. Samples of water were collected during a 6-month-period, from april to september 2000, in 16 sampling stations located strategically throughout the Rimac River. The analytical method used consists in the separation of radium and lead contained in the samples of water using barium and lead carriers, and that after some precipitation and redissolution phases, radium is coprecipitated as Ba (Ra)SO{sub 4} and the lead is precipitated as PbCrO{sub 4}. Ra-226 determination was performed through the total alpha measurement of the Ba(Ra)SO{sub 4} precipitation, and the Ra-228 determination and Pb-210 were performed by the total beta measurement of the Ba(Ra)SO{sub 4} and PbCrO{sub 4} precipitations, respectively. Measurements were carried out in a proportional counter of low-background gas flow. Activity concentrations results range from 0,0021 to 0,1754 Bq/L for the Ra-226; from 0,0025 to 0,2355 Bq/L for the Ra-228 and from 0,0026 to 0,0528 Bq/L for the Pb-210. In none of the cases the maximum concentration admissible for human consumption water is exceeded. Compared to other rivers worldwide, the Rimac River presents similar concentrations.

  10. What is lead-based paint?

    International Nuclear Information System (INIS)

    Vernon, L.S.

    1994-01-01

    The number of variety of lead-abatement regulations and requirements make it difficult and confusing to identify and properly respond to dangerous levels of lead in every situation. Definitions of ''lead-based paint'' and three test methods for lead detection are described to help determine when and how to test for the presence of lead

  11. Essential elements, cadmium, and lead in raw and pasteurized cow and goat milk

    Energy Technology Data Exchange (ETDEWEB)

    Lopez, A.; Collins, W.F.; Williams, H.L.

    1985-08-01

    Fifteen essential elements plus cadmium and lead were determined in raw and pasteurized cow and goat milks by atomic absorption spectrophotometry. When results were compared on a wet weight basis, there were no significant differences between the raw and pasteurized milks except for cobalt, iron, and lead in goat milk. When copper in goat milk was expressed on a dry weight basis, there was a significant difference between raw and pasteurized milk. There were significantly higher amounts of cobalt, copper, iron, lead, magnesium, and phosphorus, wet weight basis, in pasteurized goat milk than in pasteurized cow milk. Significantly more nickel and sodium were in pasteurized cow milk. No difference in the content of chloride, calcium, potassium, and zinc was significant between the two milks. When dry weights of the two milks were compared, statistical differences were the same, except there was significantly more calcium and potassium in pasteurized cow milk than in pasteurized goat milk and there were no significant differences in the content of lead and phosphorus between the two milks. Percentages of the established and estimated recommended daily allowances show both cow and goat milk to be excellent sources of calcium, phosphorus, and potassium and fair sources of iron, magnesium, and sodium.

  12. Glovebox enclosed dc plasma source for the determination of metals in plutonium

    International Nuclear Information System (INIS)

    Morris, W.F.

    1986-01-01

    The direct current plasma source of a Beckman Spectraspan IIIB emission spectrometer was enclosed in a glovebox at Lawrence Livermore National Laboratory in December 1982. Since that time, the system has been used for the routine determination of alloy and impurity metals in plutonium. This paper presents the systematic steps involved in developing the glovebox and gives information regarding performance of the plasma in the glovebox and the effectiveness of containment of plutonium. 8 refs., 9 figs., 3 tabs

  13. Gas cooled leads

    International Nuclear Information System (INIS)

    Shutt, R.P.; Rehak, M.L.; Hornik, K.E.

    1993-01-01

    The intent of this paper is to cover as completely as possible and in sufficient detail the topics relevant to lead design. The first part identifies the problems associated with lead design, states the mathematical formulation, and shows the results of numerical and analytical solutions. The second part presents the results of a parametric study whose object is to determine the best choice for cooling method, material, and geometry. These findings axe applied in a third part to the design of high-current leads whose end temperatures are determined from the surrounding equipment. It is found that cooling method or improved heat transfer are not critical once good heat exchange is established. The range 5 5 but extends over a large of values. Mass flow needed to prevent thermal runaway varies linearly with current above a given threshold. Below that value, the mass flow is constant with current. Transient analysis shows no evidence of hysteresis. If cooling is interrupted, the mass flow needed to restore the lead to its initially cooled state grows exponentially with the time that the lead was left without cooling

  14. Understanding handpump sustainability: Determinants of rural water source functionality in the Greater Afram Plains region of Ghana.

    Science.gov (United States)

    Fisher, Michael B; Shields, Katherine F; Chan, Terence U; Christenson, Elizabeth; Cronk, Ryan D; Leker, Hannah; Samani, Destina; Apoya, Patrick; Lutz, Alexandra; Bartram, Jamie

    2015-10-01

    Safe drinking water is critical to human health and development. In rural sub-Saharan Africa, most improved water sources are boreholes with handpumps; studies suggest that up to one third of these handpumps are nonfunctional at any given time. This work presents findings from a secondary analysis of cross-sectional data from 1509 water sources in 570 communities in the rural Greater Afram Plains (GAP) region of Ghana; one of the largest studies of its kind. 79.4% of enumerated water sources were functional when visited; in multivariable regressions, functionality depended on source age, management, tariff collection, the number of other sources in the community, and the district. A Bayesian network (BN) model developed using the same data set found strong dependencies of functionality on implementer, pump type, management, and the availability of tools, with synergistic effects from management determinants on functionality, increasing the likelihood of a source being functional from a baseline of 72% to more than 97% with optimal management and available tools. We suggest that functionality may be a dynamic equilibrium between regular breakdowns and repairs, with management a key determinant of repair rate. Management variables may interact synergistically in ways better captured by BN analysis than by logistic regressions. These qualitative findings may prove generalizable beyond the study area, and may offer new approaches to understanding and increasing handpump functionality and safe water access.

  15. Determination of lead and cadmium in biological materials

    International Nuclear Information System (INIS)

    Stoeppler, M.; Backhaus, F.; Dahl, R.; Hagedorn-Goetz, H.; Hilpert, K.; Klahre, P.; Rutzel, H.; Valenta, P.; Nuernberg, H.W.; Dumont, M.

    1975-01-01

    Sampling techniques and experience, and decomposition methods are presented. The processes used in flameless atomic absorption spectrometry (including the method using automatic insertion of samples), pulse polarography and isotope dilution mass spectrometry are described. Finally, the results of lead and cadmium measurements in bovine liver, blood, urine and hair samples are reported and discussed with a comparison of methods in some cases

  16. Safe leads and lead changes in competitive team sports

    Science.gov (United States)

    Clauset, A.; Kogan, M.; Redner, S.

    2015-06-01

    We investigate the time evolution of lead changes within individual games of competitive team sports. Exploiting ideas from the theory of random walks, the number of lead changes within a single game follows a Gaussian distribution. We show that the probability that the last lead change and the time of the largest lead size are governed by the same arcsine law, a bimodal distribution that diverges at the start and at the end of the game. We also determine the probability that a given lead is "safe" as a function of its size L and game time t . Our predictions generally agree with comprehensive data on more than 1.25 million scoring events in roughly 40 000 games across four professional or semiprofessional team sports, and are more accurate than popular heuristics currently used in sports analytics.

  17. Lead (Pb) Isotope Baselines for Studies of Ancient Human Migration and Trade in the Maya Region

    Science.gov (United States)

    Kamenov, George D.; Gilli, Adrian; Hodell, David A.; Emery, Kitty F.; Brenner, Mark; Krigbaum, John

    2016-01-01

    We examined the potential use of lead (Pb) isotopes to source archaeological materials from the Maya region of Mesoamerica. The main objectives were to determine if: 1) geologic terrains throughout the Maya area exhibit distinct lead isotope ratios (206Pb/204Pb, 207Pb/204Pb, and 208Pb/204Pb), and 2) a combination of lead and strontium ratios can enhance sourcing procedures in the Mesoamerica region. We analyzed 60 rock samples for lead isotope ratios and a representative subset of samples for lead, uranium, and thorium concentrations across the Maya region, including the Northern Lowlands of the Mexican Yucatan Peninsula, the Southern Lowlands of Guatemala and Belize, the Volcanic Highlands, the Belizean Maya Mountains, and the Metamorphic Province/Motagua Valley. Although there is some overlap within certain sub-regions, particularly the geologically diverse Metamorphic Province, lead isotopes can be used to distinguish between the Northern Lowlands, the Southern Lowlands, and the Volcanic Highlands. The distinct lead isotope ratios in the sub-regions are related to the geology of the Maya area, exhibiting a general trend in the lowlands of geologically younger rocks in the north to older rocks in the south, and Cenozoic volcanic rocks in the southern highlands. Combined with other sourcing techniques such as strontium (87Sr/86Sr) and oxygen (δ18O), a regional baseline for lead isotope ratios can contribute to the development of lead isoscapes in the Maya area, and may help to distinguish among geographic sub-regions at a finer scale than has been previously possible. These isotope baselines will provide archaeologists with an additional tool to track the origin and movement of ancient humans and artifacts across this important region. PMID:27806065

  18. Lead (Pb) Isotope Baselines for Studies of Ancient Human Migration and Trade in the Maya Region.

    Science.gov (United States)

    Sharpe, Ashley E; Kamenov, George D; Gilli, Adrian; Hodell, David A; Emery, Kitty F; Brenner, Mark; Krigbaum, John

    2016-01-01

    We examined the potential use of lead (Pb) isotopes to source archaeological materials from the Maya region of Mesoamerica. The main objectives were to determine if: 1) geologic terrains throughout the Maya area exhibit distinct lead isotope ratios (206Pb/204Pb, 207Pb/204Pb, and 208Pb/204Pb), and 2) a combination of lead and strontium ratios can enhance sourcing procedures in the Mesoamerica region. We analyzed 60 rock samples for lead isotope ratios and a representative subset of samples for lead, uranium, and thorium concentrations across the Maya region, including the Northern Lowlands of the Mexican Yucatan Peninsula, the Southern Lowlands of Guatemala and Belize, the Volcanic Highlands, the Belizean Maya Mountains, and the Metamorphic Province/Motagua Valley. Although there is some overlap within certain sub-regions, particularly the geologically diverse Metamorphic Province, lead isotopes can be used to distinguish between the Northern Lowlands, the Southern Lowlands, and the Volcanic Highlands. The distinct lead isotope ratios in the sub-regions are related to the geology of the Maya area, exhibiting a general trend in the lowlands of geologically younger rocks in the north to older rocks in the south, and Cenozoic volcanic rocks in the southern highlands. Combined with other sourcing techniques such as strontium (87Sr/86Sr) and oxygen (δ18O), a regional baseline for lead isotope ratios can contribute to the development of lead isoscapes in the Maya area, and may help to distinguish among geographic sub-regions at a finer scale than has been previously possible. These isotope baselines will provide archaeologists with an additional tool to track the origin and movement of ancient humans and artifacts across this important region.

  19. Investigation of Polluted Zones by Lead in North West of Iran

    Directory of Open Access Journals (Sweden)

    Khodadadi A.

    2014-07-01

    Full Text Available National project of Important Heavy Metals Identification of Iran (IHMI, following the UNDP and supported by Department of Environment of Iran (DOE, has been completed by Modares Environmental Research Center (MERC. Due to this project the pollution potential sources was investigated by overall distribution maps of any parameters that may cause the lead pollution. Then the sampling points was determined by some geo-statistical analysis and the sampling process was done according to standard methods of sampling, preserving, transferring to lab, measuring and analyzing etc through the 3 months in three phases of materials (effluent and discharges, solid waste, water, soil and sediment samples from natural sources like river etc.. After gathering the final results, overlaying the potential sources and polluted positions (according to violation of national and international standards of sampled points by Geographic Information Systems (GIS led the research to closing to the pollutant sources in north west provinces (Eastern Azerbaijan, Western Azerbaijan, Ardabil and Zanjan. The synthetic and natural pollution sources observed were 17 and 20 respectively. Abir River, Niroo Gostar Taban Industrial Complex and Copper Industries were the most important pollution sources in material phases of Natural, effluent and solid waste respectively.

  20. Lead determinations in human bone by particle induced x-ray emission (PIXE) and graphite furnace atomic absorption spectrometry (GFAAS)

    International Nuclear Information System (INIS)

    Deibel, M.A.; Savage, J.M.; Robertson, J.D.; Ehmann, W.D.

    1995-01-01

    Chronic lead (Pb) intoxication has been linked to Alzheimer's disease (AD). Lead, like many heavy elements, tends to accumulate in bone. Pixe is a powerful analytical tool which permits the determination of Pb at the μg/g level without requiring sample digestion. GFAAS is one of the most sensitive methods for the determination of Pb and is capable of determining ng/g levels is solution. For bone analyses by GFAAS, sample dissolution and a matrix modifier are required. Rib bone samples were analyzed for Pb by PIXE and GFAAS. IAEA Animal Bone (H-5) was used as a secondary standard for Pb with both methods to ensure accuracy. The range of Pb concentrations in human rib bone was 1.4-11.5 μ/g for the trabecular surface by PIXE, 1.3-45 μg/g for the cortical surface by PIXE, and 1.54-11.75 μg/g for whole bone by GFAAS. No significant difference (p.<0.05 was found for AD versus control for either surface or for whole bone. (author). 17 refs., 2 figs., 3 tabs

  1. Lead determinations in human bone by particle induced x-ray emission (PIXE) and graphite furnace atomic absorption spectrometry (GFAAS)

    Energy Technology Data Exchange (ETDEWEB)

    Deibel, M A; Savage, J M; Robertson, J D; Ehmann, W D [Kentucky Univ., Lexington, KY (United States). Dept. of Chemistry; Markesbery, W R [Kentucky Univ., Lexington, KY (United States)

    1995-08-01

    Chronic lead (Pb) intoxication has been linked to Alzheimer`s disease (AD). Lead, like many heavy elements, tends to accumulate in bone. Pixe is a powerful analytical tool which permits the determination of Pb at the {mu}g/g level without requiring sample digestion. GFAAS is one of the most sensitive methods for the determination of Pb and is capable of determining ng/g levels is solution. For bone analyses by GFAAS, sample dissolution and a matrix modifier are required. Rib bone samples were analyzed for Pb by PIXE and GFAAS. IAEA Animal Bone (H-5) was used as a secondary standard for Pb with both methods to ensure accuracy. The range of Pb concentrations in human rib bone was 1.4-11.5 {mu}/g for the trabecular surface by PIXE, 1.3-45 {mu}g/g for the cortical surface by PIXE, and 1.54-11.75 {mu}g/g for whole bone by GFAAS. No significant difference p.<0.05 was found for AD versus control for either surface or for whole bone. (author). 17 refs., 2 figs., 3 tabs.

  2. RADSHI: shielding calculation program for different geometries sources

    International Nuclear Information System (INIS)

    Gelen, A.; Alvarez, I.; Lopez, H.; Manso, M.

    1996-01-01

    A computer code written in pascal language for IBM/Pc is described. The program calculates the optimum thickness of slab shield for different geometries sources. The Point Kernel Method is employed, which enables the obtention of the ionizing radiation flux density. The calculation takes into account the possibility of self-absorption in the source. The air kerma rate for gamma radiation is determined, and with the concept of attenuation length through the equivalent attenuation length the shield is obtained. The scattering and the exponential attenuation inside the shield material is considered in the program. The shield materials can be: concrete, water, iron or lead. It also calculates the shield for point isotropic neutron source, using as shield materials paraffin, concrete or water. (authors). 13 refs

  3. Organic palladium and palladium-magnesium chemical modifiers in direct determination of lead in fractions from distillation of crude oil by electrothermal atomic absorption analysis

    Science.gov (United States)

    Kowalewska, Zofia; Bulska, Ewa; Hulanicki, Adam

    1999-05-01

    Platinum reforming catalysts are easily poisoned by increased levels of lead, therefore a sensitive atomic absorption spectrometric procedure for lead determination in fractions from crude oil distillation was developed. Lead was present in organic form in the samples analysed therefore the behaviour of various lead compounds (Pb-alkylarylsulphonate, Pb-4-cyclohexanobutyrate, tetraethyllead, Pb in fuel oil) was studied. The best procedure for the determination of lead in different petroleum products, including those containing asphaltenes includes a pretreatment with iodine and methyltrioctylammonium chloride, followed by the use of an organic Pd-Mg modifier. Under these conditions an effective matrix removal is possible at a pyrolysis temperature up to approximately 1100°C and the behaviour of lead present in different forms is unified. The characteristic mass is 11-12 pg Pb, corresponding to a detection limit of 0.25 ng g -1 for 20 μl sample solution. This can be lowered by multiple injection.

  4. Kinetics of oil saponification by lead salts in ancient preparations of pharmaceutical lead plasters and painting lead mediums.

    Science.gov (United States)

    Cotte, M; Checroun, E; Susini, J; Dumas, P; Tchoreloff, P; Besnard, M; Walter, Ph

    2006-12-15

    Lead soaps can be found in archaeological cosmetics as well as in oil paintings, as product of interactions of lead salts with oil. In this context, a better understanding of the formation of lead soaps allows a follow-up of the historical evolution of preparation recipes and provides new insights into conservation conditions. First, ancient recipes of both pharmaceutical lead plasters and painting lead mediums, mixtures of oil and lead salts, were reconstructed. The ester saponification by lead salts is determined by the preparation parameters which were quantified by FT-IR spectrometry. In particular, ATR/FT-IR spectrometer was calibrated by the standard addition method to quantitatively follow the kinetics of this reaction. The influence of different parameters such as temperature, presence of water and choice of lead salts was assessed: the saponification is clearly accelerated by water and heating. This analysis provides chemical explanations to the historical evolution of cosmetic and painting preparation recipes.

  5. Lead dust in broken hill homes--a potential hazard for young children?

    Science.gov (United States)

    Boreland, F; Lyle, D M; Wlodarczyk, J; Balding, W A; Reddan, S

    2002-01-01

    To determine the potential hazard posed by indoor lead dust to young children in Broken Hill, a silver-lead-zinc mining town in outback Australia, and the degree to which lead flux is influenced by factors such as geographical location, house construction type and condition. 116 homes were selected and 93 (80%) studied from 10 localities in Broken Hill during the spring of 1995. Lead flux was measured using 85 mm diameter polystyrene petri dishes. Dishes were placed in four rooms of each house to collect dust over a six-to-eight-week period. Data on the location, condition and construction type of each house were recorded. Multiple linear regression was used to determine predictors of lead flux. Flux data were log transformed for the analysis. Average household lead flux varied nearly seven-fold across districts from a low of 166 (distant from the mines), to a high of 1,104 microg/m2/30-day period (adjacent to the mines). Houses that were 'adequately sealed' had 2.9 times the lead flux, and 'poorly sealed' houses 4.3 times the flux, of 'very well sealed' houses. Construction material did not significantly affect these flux levels, and no statistically significant interactions were found between house condition and location or house type. Many Broken Hill homes have high levels of lead flux that pose a potential risk to young children. Quantification of this hazard provides useful information for the community that can help focus efforts on actions required to minimise lead dust in the home. Household dust is a potential source of lead for young children in at-risk communities. Information on lead flux in homes can assist these communities and public health agencies to better understand and deal more effectively with the problem.

  6. Mercury-free simultaneous determination of cadmium and lead at a glassy carbon electrode modified with multi-wall carbon nanotubes

    International Nuclear Information System (INIS)

    Wu Kangbing; Hu Shengshui; Fei Junjie; Bai Wen

    2003-01-01

    A multi-wall carbon nanotube (MWNT) modified glassy carbon electrode (GCE) was described for the simultaneous determination of trace levels of cadmium and lead by anodic stripping voltammetry (ASV). In pH 4.5 NaAc-HAc buffer containing 0.02 mol/l KI, Cd 2+ and Pb 2+ first adsorb onto the surface of a MWNT film coated GCE and then reduce at -1.20 V. During the positive potential sweep, reduced cadmium and lead were oxidized, and two well-defined stripping peaks appeared at -0.88 and -0.62 V. Compared with a bare GCE, a MWNT film coated GCE greatly improves the sensitivity of determining cadmium and lead. Low concentration of I - significantly enhances the stripping peak currents since it induces Cd 2+ and Pb 2+ to adsorb at the electrode surface. The striping peak currents change linearly with the concentration of Cd 2+ from 2.5x10 -8 to 1x10 -5 mol/l and with that of Pb 2+ from 2x10 -8 to 1x10 -5 mol/l. The lowest detectable concentrations of Cd 2+ and Pb 2+ are estimated to be 6x10 -9 and 4x10 -9 mol/l, respectively. The high sensitivity, selectivity, and stability of this MWNT film coated electrode demonstrated its practical application for a simple, rapid and economical determination of trace levels of Cd 2+ and Pb 2+ in water samples

  7. Determinants of the accuracy of nursing diagnoses: influence of ready knowledge, knowledge sources, disposition toward critical thinking, and reasoning skills.

    Science.gov (United States)

    Paans, Wolter; Sermeus, Walter; Nieweg, Roos; van der Schans, Cees

    2010-01-01

    The purpose of this study was to determine how knowledge sources, ready knowledge, and disposition toward critical thinking and reasoning skills influence the accuracy of student nurses' diagnoses. A randomized controlled trial was conducted to determine the influence of knowledge sources. We used the following questionnaires: (a) knowledge inventory, (b) California Critical Thinking Disposition Inventory, and (c) Health Science Reasoning Test (HSRT). The use of knowledge sources had very little influence on the accuracy of nursing diagnoses. Accuracy was significantly related to the analysis domain of the HSRT. Students were unable to operationalize knowledge sources to derive accurate diagnoses and did not effectively use reasoning skills. Copyright 2010 Elsevier Inc. All rights reserved.

  8. [Study on Content Determination of Lead and Arsenic in Four Traditional Tibetan Medicine Prescription Preparations by Wet Digestion Flow Injection-Hydride Generation-Atomic Absorption Spectrometry].

    Science.gov (United States)

    Zheng, Zhi-yuan; Du, Yu-zhi; Zhang, Ming; Yu, Ming-jie; Li, Cen; Yang, Hong-xia; Zhao, Jing; Xia, Zheng-hua; Wei, Li-xin

    2015-04-01

    Four common traditional tibetan medicine prescription preparations "Anzhijinghuasan, Dangzuo, Renqingchangjue and Rannasangpei" in tibetan areas were selected as study objects in the present study. The purpose was to try to establish a kind of wet digestion and flow injection-hydride generation-atomic absorption spectrometry (FI-HAAS) associated analysis method for the content determinations of lead and arsenic in traditional tibetan medicine under optimized digestion and measurement conditions and determine their contents accurately. Under these optimum operating conditions, experimental results were as follows. The detection limits for lead and arsenic were 0.067 and 0.012 µg · mL(-1) respectively. The quantification limits for lead and arsenic were 0.22 and 0.041 µg · mL(-1) respectively. The linear ranges for lead and arsenic were 25-1,600 ng · mL(-1) (r = 0.9995) and 12.5-800 ng · mL(-1) (r = 0.9994) respectively. The degrees of precision(RSD) for lead and arsenic were 2.0% and 3.2% respectively. The recovery rates for lead and arsenic were 98.00%-99.98% and 96.67%-99.87% respectively. The content determination results of lead and arsenic in four traditional tibetan medicine prescription preparations were as fol- lows. The contents of lead and arsenic in Anzhijinghuasan are 0.63-0.67 µg · g(-1) and 0.32-0.33 µg · g(-1) in Anzhijinghua- san, 42.92-43.36 µg · g(-1) and 24.67-25.87 µg · g(-1) in Dangzuo, 1,611. 39-1,631.36 µg · g(-1) and 926.76-956.52 µg- g(-1) in Renqing Changjue, and 1,102.28-1,119.127 µg-g(-1) and 509.96-516.87 µg · g(-1) in Rannasangpei, respectively. This study established a method for content determination of lead and arsenic in traditional tibetan medicine, and determined the content levels of lead and arsenic in four tibetan medicine-prescription preparations accurately. In addition, these results also provide the basis for the safe and effective use of those medicines in clinic.

  9. Analysis of (n, 2n) multiplication in lead

    International Nuclear Information System (INIS)

    Segev, M.

    1984-01-01

    Lead is being considered as a possible amplifier of neutrons for fusion blankets. A simple one-group model of neutron multiplications in Pb is presented. Given the 14 MeV neutron cross section on Pb, the model predicts the multiplication. Given measured multiplications, the model enables the determination of the (n, 2n) and transport cross sections. Required for the model are: P-the collision probability for source neutrons in the Pb body-and W- an average collision probability for non-virgin, non-degraded neutrons. In simple geometries, such as a source in the center of a spherical shell, P and an approximate W can be expressed analytically in terms of shell dimensions and the Pb transport cross section. The model was applied to Takahashi's measured multiplications in Pb shells in order to understand the apparent very high multiplicative power of Pb. The results of the analysis are not consistent with basic energy-balance and cross section magnitude constraints in neutron interaction theory. (author)

  10. Remanence of lead pollution in an urban river system: a multi-scale temporal and spatial study in the Seine River basin, France.

    Science.gov (United States)

    Ayrault, S; Le Pape, P; Evrard, O; Priadi, C R; Quantin, C; Bonté, P; Roy-Barman, M

    2014-03-01

    Total lead (Pb) concentration and Pb isotopic ratio ((206)Pb/(20)7Pb) were determined in 140 samples from the Seine River basin (France), covering a period of time from 1945 to 2011 and including bed sediments (bulk and size fractionated samples), suspended particulate matter (SPM), sediment cores, and combined sewer overflow (CSO) particulate matter to constrain the spatial and temporal variability of the lead sources at the scale of the contaminated Seine River basin. A focus on the Orge River subcatchment, which exhibits a contrasted land-use pattern, allows documenting the relation between hydrodynamics, urbanization, and contamination sources. The study reveals that the Pb contamination due to leaded gasoline that peaked in the 1980s has a very limited impact in the river nowadays. In the upstream Seine River, the isotopic ratio analysis suggests a pervasive contamination which origin (coal combustion and/or gasoline lead) should be clarified. The current SPM contamination trend follows the urbanization/industrialization spatial trend. Downstream of Paris, the lead from historical use originating from the Rio Tinto mine, Spain ((206)Pb/(207)Pb=1.1634 ± 0.0001) is the major Pb source. The analysis of the bed sediments (bulk and grain size fractionated) highlights the diversity of the anthropogenic lead sources in relation with the diversity of the human activities that occurred in this basin over the years. The "urban" source, defined by waste waters including the CSO samples ((206)Pb/(207)Pb=1.157 ± 0.003), results of a thorough mixing of leaded gasoline with "historical" lead over the years. Finally, a contamination mixing scheme related to hydrodynamics is proposed.

  11. Penetration of a magnetic field into superconducting lead and lead-indium alloys

    International Nuclear Information System (INIS)

    Egloff, C.; Raychaudhuri, A.K.; Rinderer, L.

    1983-01-01

    The temperature dependence of the magnetic field penetration depth of superconducting lead and lead-indium alloys has been studied over the temperature range between about 2 K and T/sub c/. Data are analyzed in terms of the microscopic theory. The difficulties of a unique analysis of the penetration data are pointed out and a strategy for the analysis is discussed. The penetration depth at T = 0K for pure lead is determined as 522 A. This value, though higher than the previously accepted value for lead, is nevertheless consistent with the strong coupling character of lead

  12. Determination of lead equivalent thickness to building blocks used in shielding of diagnostic x-ray rooms in Syria

    International Nuclear Information System (INIS)

    Kawash, A.; Khedr, M.; Wannus, K.; Souliman, J.; Al-Oudat, M.

    1998-06-01

    Lead equivalent thicknesses of various kinds of blocks (Hollow core, solid, filled, roof) with different thicknesses were determined. These blocks are widely used for building the diagnostic X-rya departments in Syria. Different applied voltages at X-ray tube (65, 85, 100, 125, 150 KVp) were examined. The results showed that the highest lead equivalent thicknesses for hollow core blocks were at 100 KVp. These equivalent thicknesses were 0.4372, 0.7008 and 0.928 mm for block thicknesses of 10, 15 and 20 cm, respectively. it was also found that, the lead equivalent thicknesses for filled, solid and concrete block were 3.5 to 4 times higher than that of the hollow core block for the same thicknesses and the applied KVp. Values obtained for roof blocks were similar to that of hollow core for the same conditions and geometry. (Author)

  13. Determination of lead and zinc concentrations in the blood and liver of the captive common green iguana (Iguana iguana).

    Science.gov (United States)

    Burns, Russell P; Paul-Murphy, Joanne

    2009-09-01

    Heavy metal toxicosis is a well-known phenomenon in wild, captive-animal, and domestic animal medicine. However, the occurrence among reptiles is not well documented. One reason for this is the lack of information regarding reference blood and tissue levels of heavy metals in reptiles. To determine normal blood lead, plasma zinc, and liver lead and zinc concentrations, blood and liver samples were collected from 4 adult and 16 juvenile, healthy green iguanas (Iguana iguana). Lead and zinc levels were measured using atomic absorption spectroscopy. Using the mean +/- two SD as the normal reference range, the present study suggests the following for captive common green iguana: 1) whole blood lead level: 0.06 +/- 0.06 microg/ml; 2) plasma zinc level: 2.68 +/- 1.66 microg/ml; 3) liver lead level (wet-weight basis): <1.0 +/- 0.0 microg/g; 4) liver lead level (dry-weight basis): <3.0 +/- 0.0 microg/g; 5) liver zinc level (wet-weight basis): 24.9 +/- 11.6 microg/g; and 6) liver zinc level (dry-weight basis): 83.4 +/- 44.6 microg/g. These values are fairly consistent with published reference levels in other mammalian and avian species.

  14. Lead and cadmium in indoor air and the urban environment

    International Nuclear Information System (INIS)

    Komarnicki, Guenter J.K.

    2005-01-01

    The present study was conducted to find potential terrestrial biomonitors for heavy metals in indoor air in an urban environment. TSP, PM 10 , and PM 2.5 were collected in three retirement facilities in the urban area of Vienna. In addition, particulate matter and soil, vegetation, and isopods (Porcellio scaber L.) were collected in the adjacent garden areas. Aerosols were sampled with a low-volume air sampler. The sampled materials were wet ashed and total lead and cadmium contents were determined. Water-soluble heavy metal concentrations were measured in aqueous extracts from air exposed filters, soil, and vegetation. Lead and cadmium were analyzed by graphite furnace AAS. Lead contents in the vegetation were inferred from water-soluble lead in soils. Lead in isopods generally reflected the contents in vegetation. Cadmium in plants probably derived from soil solutions as well as from atmospheric input. Isopods reflected the total cadmium contents in soils. Particulate matter was dominated by PM 2.5 , both with respect to mass concentrations and to heavy metal contents. The indoor aerosol was found to be influenced by human activity, indoor sources, and outdoor particles. Relationships between indoor airborne heavy metals and the contents in vegetation (lead and cadmium: positive) and isopods (lead: negative) were identified to have the potential for biomonitoring indoor air quality. - Urban vegetation and isopods are potential indicators for indoor aerial heavy metals

  15. Determination of factors through Monte Carlo method for Fricke dosimetry from 192Ir sources for brachytherapy

    International Nuclear Information System (INIS)

    David, Mariano Gazineu; Salata, Camila; Almeida, Carlos Eduardo

    2014-01-01

    The Laboratorio de Ciencias Radiologicas develops a methodology for the determination of the absorbed dose to water by Fricke chemical dosimetry method for brachytherapy sources of 192 Ir high dose rate and have compared their results with the laboratory of the National Research Council Canada. This paper describes the determination of the correction factors by Monte Carlo method, with the Penelope code. Values for all factors are presented, with a maximum difference of 0.22% for their determination by an alternative way. (author)

  16. Experimental and theoretical determination of dosimetric characteristics of IsoAid ADVANTAGETM125I brachytherapy source

    International Nuclear Information System (INIS)

    Meigooni, Ali S.; Hayes, Joshua L.; Zhang Hualin; Sowards, Keith

    2002-01-01

    125 I brachytherapy sources are being used for interstitial implants in tumor sites such as the prostate. Recently, the ADVANTAGE TM 125 I, Model IAI-125, source became commercially available for interstitial brachytherapy treatment. Dosimetric characteristics (dose rate constant, radial dose function, and anisotropy function) of this source were experimentally and theoretically determined, following the AAPM Task Group 43 recommendations. Derivation of the dose rate constant was based on recent NIST WAFAC calibration performed in accordance with their 1999 standard. Measurements were performed in Solid Water TM phantom using LiF thermoluminescent dosimeters. The theoretical calculations were performed in both Solid Water TM and water using the PTRAN Monte Carlo code. The results indicated that a dose rate constant of the new source in water was 0.98±0.03 cGy h -1 U -1 . The radial dose function of the new source was measured in Solid Water TM and calculated both in water and Solid Water TM at distances up to 10.0 cm. The anisotropy function, F(r,θ), of the new source was measured and calculated in Solid Water TM at distances of 2 cm, 3 cm, 5 cm, and 7 cm and also was calculated in water at distances ranging from 1 cm to 7 cm from the source. From the anisotropy function, the anisotropy factors and anisotropy constant were derived. The anisotropy constant of the ADVANTAGE TM 125 I source in water was found to be 0.97±0.03. The dosimetric characteristics of this new source compared favorably with those from the Amersham Health Model 6711 source. Complete dosimetric parameters of the new source are presented in this paper

  17. determination of lead at nanogram level in water samples

    African Journals Online (AJOL)

    Preferred Customer

    Environmental Pollution Control Technology of Henan Province,. Henan Normal ... storage battery, drainage from lead ore mines, paints, munitions, and petroleum refining. Many .... Therefore, this sequence was adopted in subsequent experiments. .... fluorescence spectrometer by using inexpensive and safe reagents.

  18. A binderless, covalently bulk modified electrochemical sensor: Application to simultaneous determination of lead and cadmium at trace level

    Energy Technology Data Exchange (ETDEWEB)

    Gunigollahalli Kempegowda, Raghu [Department of Studies in Chemistry, Bangalore University, Central College Campus, Bangalore 560001 (India); Malingappa, Pandurangappa, E-mail: mprangachem@gmail.com [Department of Studies in Chemistry, Bangalore University, Central College Campus, Bangalore 560001 (India)

    2012-05-30

    Highlights: Black-Right-Pointing-Pointer Proposed sensor is a new type of binderless covalent bulk modified electrode. Black-Right-Pointing-Pointer Surface can be easily renewed by simple mechanical polishing using emery sheets. Black-Right-Pointing-Pointer Free from modifier leaching during electrochemical measurements. Black-Right-Pointing-Pointer Provides long term storage stability with good reproducibility. Black-Right-Pointing-Pointer Nanomolar level detection limit achieved with selectivity. - Abstract: A new type of covalent binderless bulk modified electrode has been fabricated and used in the simultaneous determination of lead and cadmium ions at nanomolar level. The modification of graphitic carbon with 4-amino salicylic acid was carried out under microwave irradiation through the amide bond formation. The electrochemical behavior of the fabricated electrode has been carried out to decipher the interacting ability of the functional moieties present on the modifier molecules toward the simultaneous determination of Pb{sup 2+} and Cd{sup 2+} ions using cyclic and differential pulse anodic stripping voltammetry. The possible mode of interaction of functional groups with metal ions is proposed based on the pKa values of the modifier functionalities present on the surface of graphitic carbon particles. The analytical utility of the proposed sensor has been validated by measuring the lead and cadmium content from pretreated waste water samples of lead acid batteries.

  19. Determination of the concentrations of lead in raw milk in the Valley of Toluca

    International Nuclear Information System (INIS)

    Rosas Vilchis, E.

    1991-01-01

    The object of the present work, undertaken under the program of Regional and Cooperative Agreement for Nuclear Science and Technology in Latin America (ARCAL IV), was to determine the amounts of lead found in raw milk using the analytic techniques of Atomic Absorption Spectrophotometry (AAS), Inductively Coupled Plasma Atomic Emission Spectrometry (ICP-AES) and X-ray Fluorescence (FRX); so as to aid in solving problems of public health originating from elevated amounts of heavy metals in foods of animal origin. A total of thirty samples of raw milk were collected in the Valley of Toluca in Mexico, where heavy metal contaminants in the environment due to effects of rapid industrialization and urbanization, are known to have entered the food chain. The methodology, consisting in destroying organic matter in the samples by calcination, and included, in the case of AAS and ICP-AES, acid digestion. In the case of FRX, lead was extracted by ammonium 1-pyrrolidine carboditioate (APDC). The equipment to be used was calibrated and both blank and working solutions prepared in order to perform quantitative analysis. The concentrations of lead which were found in all the milk samples ranged from <0.03 to 0.31 μg/ml milk. These amounts within the maximum permissible limits, 0.5 μg/ml for all types of milk, established by the FDA. In the analysis ICP-AES gave best results as to sensitivity, precision and accuracy, followed by AAS which gave reliable results. FRX failed to detect lower limits and was, therefore, less reliable. (Author)

  20. Glasses impregnated with lead for radiation shielding

    International Nuclear Information System (INIS)

    Abd El Monem, A.M.; Kansouh, W.A.; Megahid, R.M.; Ismail, A.L.; Awad, E.M.

    2005-01-01

    The attenuation properties of glasses with different concentration of lead have been investigated for the attenuation of gamma-rays from cesium-137 and for total gamma rays using a beam of neutrons and gamma rays emitted from californium-252 source. Measurements have been performed using a gamma-ray spectrometer with Nal(T1) detector for gamma-rays emitted from 137 Cs and a neutron/gamma spectrometer with stilbene scintillator for measurement of total gamma-rays from 252 Cf neutron source. The latter applied the pulse shape discrimination technique to distinguish between recoil proton and recoil electron pulses. The obtained results given the form displayed pulse height spectra and attenuation relations which were used to derive the linear attenuation coefficient (μ), and the mass attenuation coefficient (mu/p) of the investigated glasses. In addition, calculations were performed to determine the attenuation properties of glass shields under investigation using XCOM code given by the others. A comparison of the shielding properties of these glasses with some standard shielding materials indicated that, the investigated glasses process the shielding advantages required for different nuclear technology applications

  1. The influence of declining air lead levels on blood lead-air lead slope factors in children.

    Science.gov (United States)

    Richmond-Bryant, Jennifer; Meng, Qingyu; Davis, Allen; Cohen, Jonathan; Lu, Shou-En; Svendsgaard, David; Brown, James S; Tuttle, Lauren; Hubbard, Heidi; Rice, Joann; Kirrane, Ellen; Vinikoor-Imler, Lisa C; Kotchmar, Dennis; Hines, Erin P; Ross, Mary

    2014-07-01

    It is difficult to discern the proportion of blood lead (PbB) attributable to ambient air lead (PbA), given the multitude of lead (Pb) sources and pathways of exposure. The PbB-PbA relationship has previously been evaluated across populations. This relationship was a central consideration in the 2008 review of the Pb national ambient air quality standards. The objectives of this study were to evaluate the relationship between PbB and PbA concentrations among children nationwide for recent years and to compare the relationship with those obtained from other studies in the literature. We merged participant-level data for PbB from the National Health and Nutrition Examination Survey (NHANES) III (1988-1994) and NHANES 9908 (1999-2008) with PbA data from the U.S. Environmental Protection Agency. We applied mixed-effects models, and we computed slope factor, d[PbB]/d[PbA] or the change in PbB per unit change in PbA, from the model results to assess the relationship between PbB and PbA. Comparing the NHANES regression results with those from the literature shows that slope factor increased with decreasing PbA among children 0-11 years of age. These findings suggest that a larger relative public health benefit may be derived among children from decreases in PbA at low PbA exposures. Simultaneous declines in Pb from other sources, changes in PbA sampling uncertainties over time largely related to changes in the size distribution of Pb-bearing particulate matter, and limitations regarding sampling size and exposure error may contribute to the variability in slope factor observed across peer-reviewed studies.

  2. Lead isotope ratios in six lake sediment cores from Japan Archipelago: Historical record of trans-boundary pollution sources.

    Science.gov (United States)

    Hosono, Takahiro; Alvarez, Kelly; Kuwae, Michinobu

    2016-07-15

    Sediment cores from six lakes situated from north to south on the Japanese Archipelago were collected during 2009-2010 to investigate the hypothesis that deposition of lead (Pb) was coming from East Asia (including China, South Korea and eastern part of Russia). Accumulation rates and ages of the lake sediment were estimated by the (210)Pb constant rate of supply model and (137)Cs inputs to reconstruct the historical trends of Pb accumulation. Cores from four lakes located in the north and central Japan, showed clear evidence of Pb pollution with a change in the (206)Pb/(207)Pb and (208)Pb/(207)Pb ratios in the recent sediment as compared to the deeper sediment. Among the six studied lakes, significant inputs of anthropogenic lead emissions were observed at Lake Mikazuki (north Hokkaido in north Japan), Lake Chokai (north of Honshu), and Lake Mikuriga (central part of Honshu). Pb isotopic comparison of collected core sediment and previously reported data for wet precipitation and aerosols from different Asian regions indicate that, before 1900, Pb accumulated in these three lakes was not affected by trans-boundary sources. Lake Mikazuki started to receive Pb emissions from Russia in early 1900s, and during the last two decades, this lake has been affected by trans-boundary Pb pollution from northern China. Lake Chokai has received Pb pollutant from northern China since early 1900s until 2009, whereas for the Lake Mikuriga the major Pb contaminant was transported from southern China during the past 100years. The results of our study demonstrate that Japan Archipelago has received trans-boundary Pb emissions from different parts of East Asian region depending on location, and the major source region has changed historically. Copyright © 2016 Elsevier B.V. All rights reserved.

  3. An attempt to determine positions of aerosol source by the PIXE analysis

    International Nuclear Information System (INIS)

    Matsuyama, S.; Tokai, Y.; Ishii, K.

    1999-01-01

    Aerosols were continuously collected for 2 or 3 hours during the periods of 4-27 August 1997 and of 23 March-2 April 1998 at a suburb of Sendai City (east 10 km from Sendai), and meteorological data such as wind directions, wind velocities, etc were measured at the same time. The collected aerosol samples were analyzed by the particle-induced X-ray emission (PIXE) method. Fourteen elements (S, Cl, K, Ca, Ti, V, Cr, Mn, Fe, Ni, Cu, Zn, Hg and Pb) were contained in these samples. The elemental concentrations increased in the daytime and decreased at night. It coincided with the time variation of people movement. The concentrations of Mn, Fe, Zn and Pb elements depended strongly on the direction of wind and their distributions for wind directions reflected to the position of aerosol sources. This result suggests that the position of aerosol source can be determined by measuring aerosols and wind directions at the many positions. (author)

  4. Evaluation of a new dielectric barrier discharge excitation source for the determination of arsenic with atomic emission spectrometry.

    Science.gov (United States)

    Zhu, Zhenli; He, Haiyang; He, Dong; Zheng, Hongtao; Zhang, Caixiang; Hu, Shenghong

    2014-05-01

    A low power dielectric barrier discharge excitation source was developed to determine arsenic in a cost-effective manner. Arsenic in water was reduced to AsH₃ by hydride generation (HG), which was transported to the miniature dielectric barrier discharge (DBD) excitation source for excitation and optical detection at As 193.7 nm atomic line. The DBD source consists of a quartz tube, a tungsten rod electrode, and a copper coil electrode. The main operation parameters and the potential interferences affecting the determination were investigated. The detection limit for arsenic with the proposed DBD-AES was 4.8 μg L(-1) when the HG products were dried with concentrated H₂SO₄ before introducing to DBD. Repeatability, expressed as the relative standard deviation of the spectral peak height, was 2.8% (n=11) for 0.1 mg L(-1) arsenic solution. The proposed method was successfully applied to the determinations of certified reference material (GBW08605) and nature water samples. Copyright © 2014 Elsevier B.V. All rights reserved.

  5. Soil is an important pathway of human lead exposure.

    OpenAIRE

    Mielke, H W; Reagan, P L

    1998-01-01

    This review shows the equal or greater importance of leaded gasoline-contaminated dust compared to lead-based paint to the child lead problem, and that soil lead, resulting from leaded gasoline and pulverized lead-based paint, is at least or more important than lead-based paint (intact and not pulverized) as a pathway of human lead exposure. Because lead-based paint is a high-dose source, the biologically relevant dosage is similar to lead in soil. Both lead-based paint and soil lead are asso...

  6. Theoretical and experimental determination of dosimetric characteristics for ADVANTAGE{sup TM} Pd-103 brachytherapy source

    Energy Technology Data Exchange (ETDEWEB)

    Meigooni, Ali S. [Department of Radiation Medicine, University of Kentucky Medical Center, 800 Rose Street, Lexington, Kentucky 40536 (United States)]. E-mail: alimeig@uky.edu; Dini, Sharifeh A. [Department of Radiation Medicine, University of Kentucky Medical Center, 800 Rose Street, Lexington, Kentucky 40536 (United States); Awan, Shahid B. [Department of Radiation Medicine, University of Kentucky Medical Center, 800 Rose Street, Lexington, Kentucky 40536 (United States); Dou, Kai [Department of Radiation Medicine, University of Kentucky Medical Center, 800 Rose Street, Lexington, Kentucky 40536 (United States); Koona, Rafiq A. [Department of Radiation Medicine, University of Kentucky Medical Center, 800 Rose Street, Lexington, Kentucky 40536 (United States)

    2006-08-15

    ADVANTAGE{sup TM} Pd-103 brachytherapy source has been recently introduced by IsoAid{sup TM} for prostate permanent implants. Dosimetric characteristics (Dose rate constant, radial dose function, 2D-, and 1D-anisotropy functions) of this source model have been determined using both theoretical and experimental methods, following the updated TG-43U1 protocol. Derivation of the dose rate constant was based on recent NIST WAFAC calibration performed in accordance with the 1999 Standards. Measurements were performed in Solid Water{sup TM} using LiF TLD chips and the theoretical calculations were performed in Solid Water{sup TM} and liquid water phantom materials using PTRAN Monte Carlo code. The results of the Monte Carlo simulation have shown a dose rate constant of 0.69 cGy h{sup -1} U{sup -1} in liquid water and 0.67 cGy h{sup -1} U{sup -1} in Solid Water{sup TM} medium. The measured dose rate constant in Solid Water{sup TM} was found to be 0.68{+-}8% cGy h{sup -1} U{sup -1}, which is in a good agreement (within {+-}5%) to the Monte Carlo simulated data. The 2D- and 1D-anisotropy functions of the ADVANTAGE{sup TM} Pd-103 source were calculated for radial distances ranging from 0.5 to 5.0 cm. Radial dose function was determined for radial distances ranging from 0.2 to 8.0 cm using line source approximation. All these calculations are based on L {sub eff} equal to 3.61 cm, calculated following TG-43U1 recommendations. The tabulated data for 2D-anisotropy function, 1D-anisotropy function, dose rate constant and radial dose function have been produced for clinical application of this source model.

  7. Standardization method for alpha and beta surface sources

    Energy Technology Data Exchange (ETDEWEB)

    Sahagia, M; Grigorescu, E L; Razdolescu, A C; Ivan, C [Institute of Physics and Nuclear Engineering, Institute of Atomic Physics, PO Box MG-6, R-76900 Bucharest, (Romania)

    1994-01-01

    The installation and method of standardization of large surface alpha and beta sources are presented. A multiwire, flow-type proportional counter and the associated electronics is used. The counter is placed in a lead-shield. The response of the system in (s[sup -1]/Bq) or (s[sup -1]/(particle x s[sup -1])) was determined for [sup 241] Am, [sup 239] Pu, [sup 147] Pm, [sup 204] Tl, [sup 90](Sr+Y) and [sup 137] Cs using standard sources with different dimensions, from some mm[sup 2] to 180 x 220 mm[sup 2]. The system was legally attested for expanded uncertainties of +7%. (Author).

  8. High risk of lead contamination for scavengers in an area with high moose hunting success.

    Science.gov (United States)

    Legagneux, Pierre; Suffice, Pauline; Messier, Jean-Sébastien; Lelievre, Frédérick; Tremblay, Junior A; Maisonneuve, Charles; Saint-Louis, Richard; Bêty, Joël

    2014-01-01

    Top predators and scavengers are vulnerable to pollutants, particularly those accumulated along the food chain. Lead accumulation can induce severe disorders and alter survival both in mammals (including humans) and in birds. A potential source of lead poisoning in wild animals, and especially in scavengers, results from the consumption of ammunition residues in the tissues of big game killed by hunters. For two consecutive years we quantified the level lead exposure in individuals of a sentinel scavenger species, the common raven (Corvus corax), captured during the moose (Alces alces) hunting season in eastern Quebec, Canada. The source of the lead contamination was also determined using stable isotope analyses. Finally, we identified the different scavenger species that could potentially be exposed to lead by installing automatic cameras targeting moose gut piles. Blood lead concentration in ravens increased over time, indicating lead accumulation over the moose-hunting season. Using a contamination threshold of 100 µg x L(-1), more than 50% of individuals were lead-contaminated during the moose hunting period. Lead concentration was twice as high in one year compared to the other, matching the number of rifle-shot moose in the area. Non-contaminated birds exhibited no ammunition isotope signatures. The isotope signature of the lead detected in contaminated ravens tended towards the signature from lead ammunition. We also found that black bears (Ursus americanus), golden eagles and bald eagles (Aquila chrysaetos and Haliaeetus leucocephalus, two species of conservation concern) scavenged heavily on moose viscera left by hunters. Our unequivocal results agree with other studies and further motivate the use of non-toxic ammunition for big game hunting.

  9. High risk of lead contamination for scavengers in an area with high moose hunting success.

    Directory of Open Access Journals (Sweden)

    Pierre Legagneux

    Full Text Available Top predators and scavengers are vulnerable to pollutants, particularly those accumulated along the food chain. Lead accumulation can induce severe disorders and alter survival both in mammals (including humans and in birds. A potential source of lead poisoning in wild animals, and especially in scavengers, results from the consumption of ammunition residues in the tissues of big game killed by hunters. For two consecutive years we quantified the level lead exposure in individuals of a sentinel scavenger species, the common raven (Corvus corax, captured during the moose (Alces alces hunting season in eastern Quebec, Canada. The source of the lead contamination was also determined using stable isotope analyses. Finally, we identified the different scavenger species that could potentially be exposed to lead by installing automatic cameras targeting moose gut piles. Blood lead concentration in ravens increased over time, indicating lead accumulation over the moose-hunting season. Using a contamination threshold of 100 µg x L(-1, more than 50% of individuals were lead-contaminated during the moose hunting period. Lead concentration was twice as high in one year compared to the other, matching the number of rifle-shot moose in the area. Non-contaminated birds exhibited no ammunition isotope signatures. The isotope signature of the lead detected in contaminated ravens tended towards the signature from lead ammunition. We also found that black bears (Ursus americanus, golden eagles and bald eagles (Aquila chrysaetos and Haliaeetus leucocephalus, two species of conservation concern scavenged heavily on moose viscera left by hunters. Our unequivocal results agree with other studies and further motivate the use of non-toxic ammunition for big game hunting.

  10. SU-G-201-10: Experimental Determination of Modified TG-43 Dosimetry Parameters for the Xoft Axxent® Electronic Brachytherapy Source

    International Nuclear Information System (INIS)

    Simiele, S; Palmer, B; DeWerd, L

    2016-01-01

    Purpose: The establishment of an air kerma rate standard at NIST for the Xoft Axxent"® electronic brachytherapy source (Axxent"® source) motivated the establishment of a modified TG-43 dosimetry formalism. This work measures the modified dosimetry parameters for the Axxent"® source in the absence of a treatment applicator for implementation in Xoft’s treatment planning system. Methods: The dose-rate conversion coefficient (DRCC), radial dose function (RDF) values, and polar anisotropy (PA) were measured using TLD-100 microcubes with NIST-calibrated sources. The DRCC and RDF measurements were performed in liquid water using an annulus of Virtual Water™ designed to align the TLDs at the height of the anode at fixed radii from the source. The PA was measured at several distances from the source in a PMMA phantom. MCNP-determined absorbed dose energy dependence correction factors were used to convert from dose to TLD to dose to liquid water for the DRCC, RDF, and PA measurements. The intrinsic energy dependence correction factor from the work of Pike was used. The AKR was determined using a NIST-calibrated HDR1000 Plus well-type ionization chamber. Results: The DRCC was determined to be 8.6 (cGy/hr)/(µGy/min). The radial dose values were determined to be 1.00 (1cm), 0.60 (2cm), 0.42 (3cm), and 0.32 (4cm), with agreement ranging from (5.7% to 10.9%) from the work of Hiatt et al. 2015 and agreement from (2.8% to 6.8%) with internal MCNP simulations. Conclusion: This work presents a complete dataset of modified TG-43 dosimetry parameters for the Axxent"® source in the absence of an applicator. Prior to this study a DRCC had not been measured for the Axxent"® source. This data will be used for calculating dose distributions for patients receiving treatment with the Axxent"® source in Xoft’s breast balloon and vaginal applicators, and for intraoperative radiotherapy. Sources and partial funding for this work were provided by Xoft Inc. (a subsidiary of i

  11. Blood lead and lead-210 origins in residents of Toulouse

    International Nuclear Information System (INIS)

    Servant, J.; Delapart, M.

    1981-01-01

    Blood lead and lead-210 analyses were performed on blood samples from non-smoking residents of Toulouse (city of 400,000 inhabitants). Simultaneous surface soil lead content determinations were carried out by the same procedure on rural zone samples of southwestern France. The observed isotopic ratios were compared in order to evaluate food chain contamination. For an average of 19.7 +- 5.8 μg 100 cc -1 of lead in blood, atmospheric contamination amounts to 20%, estimated as follows: 6% from direct inhalation and 14% from dry deposits on vegetation absorbed as food. The natural levels carried over by the food chain reach 14.9 μg 100 cc -1 and have a 210 Pb/Pb concentration ratio of 0.055 dpmμg -1 . These results lead to a maximum value of 15 μg 100 cc -1 for natural lead in human blood according to the ICRP model. (author)

  12. Mercury-free simultaneous determination of cadmium and lead at a glassy carbon electrode modified with multi-wall carbon nanotubes

    Energy Technology Data Exchange (ETDEWEB)

    Wu Kangbing; Hu Shengshui; Fei Junjie; Bai Wen

    2003-08-18

    A multi-wall carbon nanotube (MWNT) modified glassy carbon electrode (GCE) was described for the simultaneous determination of trace levels of cadmium and lead by anodic stripping voltammetry (ASV). In pH 4.5 NaAc-HAc buffer containing 0.02 mol/l KI, Cd{sup 2+} and Pb{sup 2+} first adsorb onto the surface of a MWNT film coated GCE and then reduce at -1.20 V. During the positive potential sweep, reduced cadmium and lead were oxidized, and two well-defined stripping peaks appeared at -0.88 and -0.62 V. Compared with a bare GCE, a MWNT film coated GCE greatly improves the sensitivity of determining cadmium and lead. Low concentration of I{sup -} significantly enhances the stripping peak currents since it induces Cd{sup 2+} and Pb{sup 2+} to adsorb at the electrode surface. The striping peak currents change linearly with the concentration of Cd{sup 2+} from 2.5x10{sup -8} to 1x10{sup -5} mol/l and with that of Pb{sup 2+} from 2x10{sup -8} to 1x10{sup -5} mol/l. The lowest detectable concentrations of Cd{sup 2+} and Pb{sup 2+} are estimated to be 6x10{sup -9} and 4x10{sup -9} mol/l, respectively. The high sensitivity, selectivity, and stability of this MWNT film coated electrode demonstrated its practical application for a simple, rapid and economical determination of trace levels of Cd{sup 2+} and Pb{sup 2+} in water samples.

  13. The direct determination, by differential pulse anodic-stripping voltammetry at the thin mercury-film electrode, of cadmium, lead and copper

    International Nuclear Information System (INIS)

    Lee, A.F.

    1981-01-01

    This report describes the development and application of a voltammetric procedure for the direct, simultaneous determination of cadmium, lead, and copper in three SAROC reference materials (carbonatite, magnesite, and quartz). The electrolyte was a mixture of 1 M ammonium chloride, 0,1 M citric acid, and 0,025 M ascorbic acid. No interferences were encountered from Fe(III), As(III), Sb(V), Tl(I), or In(III) at the concentrations present in the samples. Intermetallic interferences were eliminated by the use of thin mercury-film electrodes not less than 80nm thick. Limits of detection were determined by the degree to which the supporting electrolyte could be purified, and were estimated to be 10ng/g, 250ng/g, and 150ng/g for cadmium, lead, and copper respectively

  14. Development of a method for multielemental determination in water by EDXRF with radioisotopic source of 238Pu

    International Nuclear Information System (INIS)

    Serrano, C.; Estévez, J.; Montero, A.; Pupo, I.; Herrero, Z.; Leyva, D.; Arteche, J.; Varcárcel, L.; Van Espen, P.; Santos Júnior, J. A. dos

    2017-01-01

    A method for determination of Cr, Fe, Co, Ni, Cu, Zn, Hg and Pb in waters by Energy Dispersive X Ray Fluorescence (EDXRF) was implemented, using a radioisotopic source of 238 Pu. For previous concentration was employed a procedure including a coprecipitation step with ammonium pyrrolidine dithiocarbamate (APDC) as quelant agent, the separation of the phases by filtration, the measurement of filter by EDXRF and quantification by a thin layer absolute method. Sensitivity curves for K and L lines were obtained respectively. The sensitivity for most elements was greater by an order of magnitude in the case of measurement with a source of 238 Pu instead of 109 Cd, which means a considerable decrease in measurement times. The influence of the concentration in the precipitation efficiency was evaluated for each element. In all cases the recoveries are close to 100%, for this reason it can be affirmed that the method of determination of the studied elements is quantitative. Metrological parameters of the method such as trueness, precision, detection limit and uncertainty were calculated. A procedure to calculate the uncertainty of the method was elaborated; the most significant source of uncertainty for the thin layer EDXRF method is associated with the determination of instrumental sensitivities. The error associated with the determination, expressed as expanded uncertainty (in %), varied from 15.4% for low element concentrations (2.5-5 μg/L) to 5.4% for the higher concentration range (20-25 μg/L). (author)

  15. Determination of lead levels in roadside soil and plants in Damascus city

    International Nuclear Information System (INIS)

    Othman, I; Al-Oudat, M.; Al-Masri, M.S.

    1997-04-01

    Seasonal variations of lead concentration in roadside soils and plants in 12 sites in Damascus city have been investigated. Lead concentrations in soil were found to be varied from 78.4 ppm to 832 ppm; lower levels in the wet period than in the dry period were observed. While lead levels in roadside plants varied between 3.39 ppm to 13.28 ppm. The results have also shown that most of the vegetables grown on the roadside of Damascus city have high concentrations of lead and the normal washing does not decrease it to unacceptable level. (author). 15 refs., 9 tabs

  16. Air-kerma strength determination of a new directional 103Pd source

    International Nuclear Information System (INIS)

    Aima, Manik; Reed, Joshua L.; DeWerd, Larry A.; Culberson, Wesley S.

    2015-01-01

    Purpose: A new directional 103 Pd planar source array called a CivaSheet™ has been developed by CivaTech Oncology, Inc., for potential use in low-dose-rate (LDR) brachytherapy treatments. The array consists of multiple individual polymer capsules called CivaDots, containing 103 Pd and a gold shield that attenuates the radiation on one side, thus defining a hot and cold side. This novel source requires new methods to establish a source strength metric. The presence of gold material in such close proximity to the active 103 Pd region causes the source spectrum to be significantly different than the energy spectra of seeds normally used in LDR brachytherapy treatments. In this investigation, the authors perform air-kerma strength (S K ) measurements, develop new correction factors for these measurements based on an experimentally verified energy spectrum, and test the robustness of transferring S K to a well-type ionization chamber. Methods: S K measurements were performed with the variable-aperture free-air chamber (VAFAC) at the University of Wisconsin Medical Radiation Research Center. Subsequent measurements were then performed in a well-type ionization chamber. To realize the quantity S K from a directional source with gold material present, new methods and correction factors were considered. Updated correction factors were calculated using the MCNP 6 Monte Carlo code in order to determine S K with the presence of gold fluorescent energy lines. In addition to S K measurements, a low-energy high-purity germanium (HPGe) detector was used to experimentally verify the calculated spectrum, a sodium iodide (NaI) scintillating counter was used to verify the azimuthal and polar anisotropy, and a well-type ionization chamber was used to test the feasibility of disseminating S K values for a directional source within a cylindrically symmetric measurement volume. Results: The UW VAFAC was successfully used to measure the S K of four CivaDots with reproducibilities within

  17. Determination of the direction to a source of antineutrinos via inverse beta decay in Double Chooz

    Science.gov (United States)

    Nikitenko, Ya.

    2016-11-01

    To determine the direction to a source of neutrinos (and antineutrinos) is an important problem for the physics of supernovae and of the Earth. The direction to a source of antineutrinos can be estimated through the reaction of inverse beta decay. We show that the reactor neutrino experiment Double Chooz has unique capabilities to study antineutrino signal from point-like sources. Contemporary experimental data on antineutrino directionality is given. A rigorous mathematical approach for neutrino direction studies has been developed. Exact expressions for the precision of the simple mean estimator of neutrinos' direction for normal and exponential distributions for a finite sample and for the limiting case of many events have been obtained.

  18. Quantitative determination of minor and trace elements in rocks and soils by spark source mass spectrometry

    International Nuclear Information System (INIS)

    Ure, A.M.; Bacon, J.R.

    1978-01-01

    Experimental details are given of the quantitative determination of minor and trace elements in rocks and soils by spark source mass spectrometry. The effects of interfering species, and corrections that can be applied, are discussed. (U.K.)

  19. Atmospheric and children's blood lead as indicators of vehicular traffic and other emission sources in Mumbai, India

    Energy Technology Data Exchange (ETDEWEB)

    Tripathi, R.M.; Raghunath, R.; Vinod Kumar, A.; Sastry, V.N.; Sadasivan, S. [Environmental Assessment Division, Bhabha Atomic Research Centre, 400 085 Mumbai (India)

    2001-02-21

    Average concentration of Pb in atmospheric air particulates in different suburbs of Mumbai was studied for almost a decade and its spatial and temporal profiles are discussed in relation to emission sources. In general the concentration of Pb in all the residential suburban atmosphere is well below the Central Pollution Control Board (CPCB, 1994) prescribed limit of 1.5 {mu}g m{sup -3} barring a few exceptions for some residential/industrial sites, such as those of Thane and Kurla scrap yards. The correlation between blood lead of children and air lead reveals that the blood Pb level in children could increase by 3.6 {mu}g dl{sup -1} for an incremental rise of 1.0 {mu}g Pb m{sup -3} of air. The temporal profile of air Pb values indicates a decreasing trend in residential suburbs (Khar: 1984, 0.39 {mu}g m{sup -3}; 1996, 0.17 {mu}g m{sup -3}) as well as in suburban residential areas with low traffic (Goregaon: 1984, 0.53 {mu}g m{sup -3}; 1996, 0.30 {mu}g m{sup -3})

  20. Manurial properties of lead nitrate

    Energy Technology Data Exchange (ETDEWEB)

    Berry, R A

    1924-01-01

    Water culture, pot and field experiments were conducted in order to determine the toxic and stimulating limit of lead nitrate in solution. Oats and rye grass were evaluated for evidence of lead poisoning. Results indicate that except in solutions of fairly high concentration, soil adsorbs the lead and destroys the toxicity of soluble lead salts. There was evidence to show that the addition of lead salts increased the rate of nitrification in soil.

  1. Lead Concentrations and Risk Exposure Assessment in Surface ...

    African Journals Online (AJOL)

    ADOWIE PERE

    µm, < 250 µm, and < 75 µm of surface soils at undeveloped residential lands leased to ... mechanic yards may still be point sources of lead ..... therefore need to conduct a source apportionment ... heavy metals in soil profiles of automobile.

  2. Demographic Information Sources and Utilization as Determinants of Educational Policy Making in South Western Nigeria

    Science.gov (United States)

    Gbadamosi, Belau Olatunde

    2013-01-01

    The paper examines demographic information sources and utilization as determinants of educational policy making in South West Nigeria. Using validated and structured questionnaire, the study population of 398 officers in the ministries of education in the affected states were enumerated. The study establishes population census, vital registration,…

  3. Biological index of environmental lead pollution: accumulation of lead in liver and kidney in mice.

    Science.gov (United States)

    Takano, T; Okutomi, Y; Mochizuki, M; Ochiai, Y; Yamada, F; Mori, M; Ueda, F

    2015-12-01

    Lead (Pb) is known to be highly poisonous, and the acute poisoning of Cd causes the abdominal pains, vomiting, and shock. The digestive and nervous symptom is observed in the chronic lead poisoning. It was also known that the defect in hemoglobin synthesis by Pb produce anemia. The release of Pb into the environment presents a source of exposure for wild animals. In this study, we examined the utility of a new Pb-monitoring index in mice administered Pb. A solution containing 0.02, 0.2, 2, or 4 ppm lead chloride (PbCl2) was administered intraperitoneally to mice, and the Pb contents of the kidney and liver were determined at designated time points. The mean Pb content of both organs increased depending on the administered Pb dosage. Although the results of control was near the detection limits, the administration of 4 ppm in 4 weeks resulted in Pb levels of 260 mg ppm/wet weight and 110 ppm wet weight in the kidney and liver, respectively. However, there were no significant relationships among administered dose, duration of Pb treatment, and liver or kidney Pb content. Then, values in all mice administered control or 0.02 mg Pb were located inside the ellipse, representing the confidence area of the new index, and values in all mice administered more than 2 mg Pb were located outside the ellipse. These results confirm that animals exposed to high concentrations of Pb would be detected by this new index.

  4. Determination of Cr, Mn, Si, and Ni in carbon steels by optical emission spectrometry with spark source

    International Nuclear Information System (INIS)

    Garcia Gonzalez, M.A.; Pomares Alfonso, M.; Mora Lopez, L.

    1995-01-01

    Elemental composition of steels determines some important of his characteristic moreover it is necessary to obtain their quality certification. Analytical procedure has performed for determination of Cr, Mn, Si and Ni in carbon steels by optical emission spectrometry with spark source. reproducibility of results is 5-11 %. Exactitude has tested with results that have obtained by internationally recognised methods-

  5. Hybrid unscented particle filter based state-of-charge determination for lead-acid batteries

    International Nuclear Information System (INIS)

    Shen, Yanqing

    2014-01-01

    Accurate prediction of cell SOC (state of charge) is important for the safety and functional capabilities of the battery energy storage application system. This paper presents a hybrid UPF (unscented particle filter) based SOC determination combined model for batteries. To simulate the entire dynamic electrical characteristics of batteries, a novel combined state space model, which takes current as a control input and let SOC and two constructed parameters as state variables, is advanced to represent cell behavior. Besides that, an improved UPF method is used to evaluate cell SOC. Taking lead-acid batteries for example, we apply the established model for test. Results show that the evolved combined state space cell model simulates battery dynamics robustly with high accuracy and the prediction value based on the improved UPF method converges to the real SOC very quickly within the error of±2%. - Highlights: • This paper introduces a hybrid UPF based SOC determination model for batteries. • The evolved model takes SOC and two constructed parameters as state variables. • The combined state space cell model simulates battery dynamics robustly. • NLMS based method is employed to lessen search space and fasten convergence process. • Novel model converges to the real SOC robustly and quickly with fewer particles

  6. Lead line in rodents: an old sign of lead intoxication turned into a new method for environmental surveillance.

    Science.gov (United States)

    de Figueiredo, Fellipe Augusto Tocchini; Ramos, Junia; Kawakita, Erika R Hashimoto; Bilal, Alina S; de Sousa, Frederico B; Swaim, William D; Issa, Joao P Mardegan; Gerlach, Raquel F

    2016-11-01

    The "lead line" was described by Henry Burton in 1840. Rodents are used as sentinels to monitor environmental pollution, but their teeth have not been used to determine lead. To determine whether lead deposits can be observed in the teeth of lead-exposed animals, since the gingival deposits known as "lead line" would likely have a correlate in the calcified tissue to which the gums are opposed during life. Male Wistar rats were exposed to lead in the drinking water (30 mg/L) since birth until 60 days-old. Molars and the incisors of each hemimandible were analyzed by scanning electron microscopy (SEM) on regular and backscattered electrons (BSE) mode. Elements were determined using electron dispersive spectroscopy (EDS). Clean cervical margins were observed on control teeth, as opposed to the findings of extensive deposits on lead-exposed animals, even in hemimandibles that had been exhumed after being buried for 90 days. BSE/EDS indicated that those deposits were an exogenous material compatible with lead sulfite. Presence of calcium, phosphorus, magnesium, carbon, lead, and oxygen is presented. Lead-exposed animals presented marked root resorption. The lead deposits characterized here for the first time show that the "lead line" seen in gums has a calcified tissue counterpart, that is detectable post-mortem even in animals exposed to a low dose of lead. This is likely a good method to detect undue lead exposure and will likely have wide application for pollution surveillance using sentinels.

  7. Petrol with isotopically differentiated lead added

    International Nuclear Information System (INIS)

    Magi, F.; Facchetti, S.; Garibaldi, P.

    1975-01-01

    An experiment is proposed aimed at determining the role of motor traffic in the pollution of the environment by lead, in particular of air, soil, vegetation, food and the human body. The technique of determining the isotopic composition of lead, used in the right way, should enable the whole problem to be solved. It is intended to add lead with a constant isotopic composition different from that of normally occuring lead, whether natural in origin or otherwise, to petrol in at least two regions of Italy. Analyses of lead samples taken from the principal mines have shown that Australian lead (Broken Hill Mine) has quite a different isotopic composition. This lead will therefore be used to prepare the antiknock additives for petrol sold in the regions in question. Adequate sampling should make it possible to determine the contribution to pollution of lead from motor vehicle exhausts. The regions chosen for the experiment are Piedmont (city and province of Turin) and Sardinia (city and province of Cagliari) - the first because of its high traffic density and level of industrialization, the second because of its remoteness and the lead content of the soil, which may affect food. Both regions present favourable conditions for supplying petrol of the intended type. The experiment is intended to last three years; the petrol with Australian lead will be marketed for a period of 18 months. The first results of analyses of the isotopic composition of lead contained in atmospheric dust in the city of Turin and of lead from a number of blood samples are reported in the paper

  8. Determination of trace amounts of impurities in molybdenum by spark source and glow discharge mass spectrometry

    International Nuclear Information System (INIS)

    Saito, Morimasa

    1994-01-01

    For the determination of trace and ultra-trace amounts of impurities in high-purity molybdenum, spark source mass spectrometry and glow discharge mass spectrometry were studied. In spark source mass spectrometry using the metal probe method, the liquid-helium cryogenic pump was used in order to protect the surface of the samples from oxidation. The theoretical relative sensitivity factors (Mo=1) calculated from physical properties were used. The analytical results obtained for molybdenum tablet and high-purity molybdenum were in good agreement with those obtained by other methods (atomic absorption spectrometry and others). In glow discharge mass spectrometry, the relative sensitivity factors were calculated by using the results obtained by spark source mass spectrometry and atomic absorption spectrometry, and this method was applied to the determination of ultra-trace amounts of impurities in ultra high-purity molybdenum and gave the satisfactory results. The detection limits (2σ, n=10) in the integration time of 600 s for U and Th were 0.6 ppb and 0.3 ppb, and the values for Al, Si, Cr, Mn and Cu were in the range of 10 ppb to 0.5 ppb. (author)

  9. Pseudo-stir bar hollow fiber solid/liquid phase microextraction combined with anodic stripping voltammetry for determination of lead and cadmium in water samples

    Directory of Open Access Journals (Sweden)

    Zarrin Es’haghi

    2014-11-01

    Full Text Available A new procedure is presented for the determination of low concentrations of lead and cadmium in water samples. Ligand assisted pseudo-stir bar hollow fiber solid/liquid phase microextraction using sol–gel sorbent reinforced with carbon nanotubes was combined with differential pulse anodic stripping voltammetry for simultaneous determination of cadmium and lead in tap water, and Darongar river water samples. In the present work, differential pulse anodic stripping voltammetry (DPASV using a hanging mercury drop electrode (HMDE was used in order to determine the ultra trace level of lead and cadmium ions in real samples. This method is based on accumulation of lead and cadmium ions on the electrode using different ligands; Quinolin-8-ol, 5,7-diiodo quinoline-8-ol, 4,5-diphenyl-1H-imidazole-2(3H-one and 2-{[2-(2-Hydroxy-ethylamino-ethylamino]-methyl}-phenol as the complexing agent. The optimized conditions were obtained. The relationship between the peak current versus concentration was linear over the range of 0.05–500 ng mL−1 for Cd (II and Pb (II. The limits of detection for lead and cadmium were 0.015 ng mL−1 and 0.012 ng mL−1, respectively. Under the optimized conditions, the pre-concentration factors are 2440 and 3710 for Cd (II and Pb (II in 5 mL of water sample, respectively.

  10. The adjoint method for general EEG and MEG sensor-based lead field equations

    International Nuclear Information System (INIS)

    Vallaghe, Sylvain; Papadopoulo, Theodore; Clerc, Maureen

    2009-01-01

    Most of the methods for the inverse source problem in electroencephalography (EEG) and magnetoencephalography (MEG) use a lead field as an input. The lead field is the function which relates any source in the brain to its measurements at the sensors. For complex geometries, there is no analytical formula of the lead field. The common approach is to numerically compute the value of the lead field for a finite number of point sources (dipoles). There are several drawbacks: the model of the source space is fixed (a set of dipoles), and the computation can be expensive for as much as 10 000 dipoles. The common idea to bypass these problems is to compute the lead field from a sensor point of view. In this paper, we use the adjoint method to derive general EEG and MEG sensor-based lead field equations. Within a simple framework, we provide a complete review of the explicit lead field equations, and we are able to extend these equations to non-pointlike sensors.

  11. Determination of regression functions for the charging and discharging processes of valve regulated lead-acid batteries

    Directory of Open Access Journals (Sweden)

    Vukić Vladimir Đ.

    2012-01-01

    Full Text Available Following a deep discharge of AGM SVT 300 valve-regulated lead-acid batteries using the ten-hour discharge current, the batteries were charged using variable current. In accordance with the obtained results, exponential and polynomial functions for the approximation of the specified processes were analyzed. The main evaluation instrument for the quality of the implemented approximations was the adjusted coefficient of determination R-2. It was perceived that the battery discharge process might be successfully approximated with both an exponential and the second order polynomial function. On all the occasions analyzed, values of the adjusted coefficient of determination were greater than 0.995. The charging process of the deeply discharged batteries was successfully approximated with the exponential function; the measured values of the adjusted coefficient of determination being nearly 0.95. Apart from the high measured values of the adjusted coefficient of determination, polynomial approximations of the second and third order did not provide satisfactory results regarding the interpolation of the battery charging characteristics. A possibility for a practical implementation of the procured regression functions in uninterruptible power supply systems was described.

  12. Multiwalled carbon nanotubes as a sorbent material for the solid phase extraction of lead from urine and subsequent determination by electrothermal atomic absorption spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Peña Crecente, Rosa M.; Lovera, Carlha Gutiérrez; García, Julia Barciela; Méndez, Jennifer Álvarez; Martín, Sagrario García; Latorre, Carlos Herrero, E-mail: carlos.herrero@usc.es

    2014-11-01

    The determination of lead in urine is a way of monitoring the chemical exposure to this metal. In the present paper, a new method for the Pb determination by electrothermal atomic absorption spectrometry (ETAAS) in urine at low levels has been developed. Lead was separated from the undesirable urine matrix by means of a solid phase extraction (SPE) procedure. Oxidized multiwalled carbon nanotubes have been used as a sorbent material. Lead from urine was retained at pH 4.0 and was quantitatively eluted using a 0.7 M nitric acid solution and was subsequently measured by ETAAS. The effects of parameters that influence the adsorption–elution process (such as pH, eluent volume and concentration, sampling and elution flow rates) and the atomic spectrometry conditions have been studied by means of different factorial design strategies. Under the optimized conditions, the detection and quantification limits obtained were 0.08 and 0.26 μg Pb L{sup −1}, respectively. The results demonstrate the absence of a urine matrix effect and this is the consequence of the SPE process carried out. Therefore, the developed method is useful for the analysis of Pb at low levels in real samples without the influence of other urine components. The proposed method was applied to the determination of lead in urine samples of unexposed healthy people and satisfactory results were obtained (in the range 3.64–22.9 μg Pb L{sup −1}). - Highlights: • Lead determination in urine using a solid phase extraction procedure followed by ETAAS • Carbon nanotubes as SPE adsorbent for Pb in urine • Matrix elimination for the Pb determination in urine by using SPE based on carbon nanotubes • The detection limit was 0.08 μg Pb L{sup −1}.

  13. Targeting acetylcholinesterase: identification of chemical leads by high throughput screening, structure determination and molecular modeling.

    Directory of Open Access Journals (Sweden)

    Lotta Berg

    Full Text Available Acetylcholinesterase (AChE is an essential enzyme that terminates cholinergic transmission by rapid hydrolysis of the neurotransmitter acetylcholine. Compounds inhibiting this enzyme can be used (inter alia to treat cholinergic deficiencies (e.g. in Alzheimer's disease, but may also act as dangerous toxins (e.g. nerve agents such as sarin. Treatment of nerve agent poisoning involves use of antidotes, small molecules capable of reactivating AChE. We have screened a collection of organic molecules to assess their ability to inhibit the enzymatic activity of AChE, aiming to find lead compounds for further optimization leading to drugs with increased efficacy and/or decreased side effects. 124 inhibitors were discovered, with considerable chemical diversity regarding size, polarity, flexibility and charge distribution. An extensive structure determination campaign resulted in a set of crystal structures of protein-ligand complexes. Overall, the ligands have substantial interactions with the peripheral anionic site of AChE, and the majority form additional interactions with the catalytic site (CAS. Reproduction of the bioactive conformation of six of the ligands using molecular docking simulations required modification of the default parameter settings of the docking software. The results show that docking-assisted structure-based design of AChE inhibitors is challenging and requires crystallographic support to obtain reliable results, at least with currently available software. The complex formed between C5685 and Mus musculus AChE (C5685•mAChE is a representative structure for the general binding mode of the determined structures. The CAS binding part of C5685 could not be structurally determined due to a disordered electron density map and the developed docking protocol was used to predict the binding modes of this part of the molecule. We believe that chemical modifications of our discovered inhibitors, biochemical and biophysical

  14. Determination of lead and cadmium in hen eggs by graphite france electrothermal atomic absorption spectrometry and estimation of the daily intake

    International Nuclear Information System (INIS)

    Siddiqui, I.; Nizami, S.S.

    2012-01-01

    A total of 54 hen eggs were procured from nine poultry farms of Sindh, Pakistan in different batches to determine lead and cadmium toxicity. The quantitative analysis of lead (Pb) and cadmium (Cd) in egg samples were performed on electrothermal atomic absorption spectrometer (ETAAS), with Zeeman effects background correction. Lead concentrations in hen egg samples ranged from 0.027 to 1.056 micro g/g with a mean value of 0.283 micro g/g +- 0.86, whereas cadmium concentrations ranged from 0.001 to 0.012 micro g/g with a mean value of 0.003 micro g/g +-0.002. Lead concentrations exceeded the normal levels of 0.020 but cadmium was found lower than the normal levels of 0.005 micro g/g. (author)

  15. Chronic lead intoxication; Chronische Bleiintoxikation

    Energy Technology Data Exchange (ETDEWEB)

    Wieseler, B.; Leng, G. [Duesseldorf Univ. (Germany). Inst. fuer Hygiene; Lenz, S.; Schultz, C. [Klinikum Remscheid GmbH, Remscheid (Germany); Wilhelm, M. [Bochum Univ. (Germany). Inst. fuer Hygiene, Sozial- und Umweltmedizin

    1999-02-01

    The case of a female 68 years old patient is described. Here, a chronic lead intoxication was diagnosed after a two year old medical history with increasing attacks of colic-like abdominal pain often described as life-threatening. After repeated hospitalizations and intensive search for the cause of the symptoms, porphyria and anemia was found to be a sign of a chronic lead poisoning. The blood lead concentrations were always about a level of 600 {mu}g/L. The source of exposure could not be found by now. Neither home inspection nor environmental investigations have shown a recent source of lead intake by the patient. However, a possible occupational source of lead exposure at a blast furnace was established by anamnesis for 1952 to 1962. Thus, osteoporosis induced lead mobilisation was suspected. Noticeable are the results of the six abdominal survey radiographies taken during hospitalization within one year; three radiographies were taken following clinical admission and three before discharge of the patient. In comparison, the course shows a chronic relapsing alimentary supply from metallic particles of unknown genesis. The patient was treated with the sodium salt of 2,3-dimercapto-1-propansulfonic acid (DMPS, Dimaval{sup TM}). She was free of complain afterwards. Following therapy, the blood lead concentrations fell under a level of 400 {mu}m/L, but after several weeks the lead level raised up to the original level of 600 {mu}g/L. (orig.) [Deutsch] Es wird eine 68jaehrige Patientin vorgestellt, bei der nach fast zweijaehriger Krankengeschichte, die gekennzeichnet war durch rezidivierende, teils als lebensbedrohlich geschilderte Bauchkoliken, eine chronische Bleiintoxikation diagnostiziert wurde. Erst nach wiederholten stationaeren Krankenhausaufenthalten mit intensiver Suche nach der Krankheitsursache wurden das Krankheitsbild und die Laborwerte durch Zusatzuntersuchungen ergaenzt, so dass sich in der festgestellten Porphyrie und Anaemie die Diagnose der

  16. Use of the Drawing-Writing Technique to Determine the Level of Knowledge of Pre-Service Teachers Regarding Renewable Energy Sources

    Science.gov (United States)

    Kara, Filiz

    2015-01-01

    The aim of this study was to determine the level of knowledge of pre-service science teachers in Turkey regarding the different types of renewable energy sources, the methods used for obtaining energy from these sources, and the areas of use for these energy sources. Within the context of the study, the drawing-writing technique was used in order…

  17. Handbook on lead-bismuth eutectic alloy and lead properties, materials compatibility, thermal-hydraulics and technologies

    International Nuclear Information System (INIS)

    2007-01-01

    As part of the development of advanced nuclear systems, including accelerator-driven systems (ADS) proposed for high-level radioactive waste transmutation and generation IV reactors, heavy liquid metals such as lead (Pb) or lead-bismuth eutectic (LBE) are under evaluation as reactor core coolant and ADS neutron target material. Heavy liquid metals are also being envisaged as target materials for high-power neutron spallation sources. The objective of this handbook is to collate and publish properties and experimental results on Pb and LBE in a consistent format in order to provide designers with a single source of qualified properties and data and to guide subsequent development efforts. The handbook covers liquid Pb and LBE properties, materials compatibility and testing issues, key aspects of the thermal-hydraulics and system technologies, existing test facilities, open issues and perspectives. (author)

  18. Voltammetric determination of cadmium and lead in human hair as healthy indicator

    International Nuclear Information System (INIS)

    Nasser, H.; Kherbik, R.

    2010-01-01

    Cadmium and Lead level were examined in hair of patients and healthy donors. Hair sample were collected and analyzed for their contents of the trace metals (Cd, Pb) by Voltammetry. It was found that the existence of Cadmium and Lead in the hair was significantly higher in the patients (19.7 μg/g - 38.2 μg/g) for lead, (0.4 μg/g - 2.1 μg/g) for cadmium. On the other hand, the healthy had lower concentration (7.8 μg/g - 8.8 μg/g) for Lead, (0.2 μg/g - 0.3 μg/g) for cadmium. In this study, hairs were analyzed to find the effect these elements on health. Correlation coefficients between the levels of the elements in hair found in this study showed that hair is a good indicator of Cadmium and Lead in the hair. The method is applicable as a tool for monitoring pollution level of groups.(author)

  19. Seasonal variations in the sources of natural and anthropogenic lead deposited at the East Rongbuk Glacier in the high-altitude Himalayas

    International Nuclear Information System (INIS)

    Burn-Nunes, Laurie; Vallelonga, Paul; Lee, Khanghyun; Hong, Sungmin; Burton, Graeme; Hou, Shugui; Moy, Andrew; Edwards, Ross; Loss, Robert; Rosman, Kevin

    2014-01-01

    Lead (Pb) isotopic compositions and concentrations, and barium (Ba) and indium (In) concentrations have been analysed at sub-annual resolution in three sections from a < 110 m ice core dated to the 18th and 20th centuries, as well as snow pit samples dated to 2004/2005, recovered from the East Rongbuk Glacier in the high-altitude Himalayas. Ice core sections indicate that atmospheric chemistry prior to ∼ 1953 was controlled by mineral dust inputs, with no discernible volcanic or anthropogenic contributions. Eighteenth century monsoon ice core chemistry is indicative of dominant contributions from local Himalayan sources; non-monsoon ice core chemistry is linked to contributions from local (Himalayan), regional (Indian/Thar Desert) and long-range (North Africa, Central Asia) sources. Twentieth century monsoon and non-monsoon ice core data demonstrate similar seasonal sources of mineral dust, however with a transition to less-radiogenic isotopic signatures that suggests local and regional climate/environmental change. The snow pit record demonstrates natural and anthropogenic contributions during both seasons, with increased anthropogenic influence during non-monsoon times. Monsoon anthropogenic inputs are most likely sourced to South/South-East Asia and/or India, whereas non-monsoon anthropogenic inputs are most likely sourced to India and Central Asia. - Highlights: • Pb isotopes in ice and snow show seasonality in Mt Everest atmospheric chemistry. • Local (Himalayan) mineral dust inputs are present year round. • Regional and long-range mineral dust inputs are evident during non-monsoon times. • Snow samples indicate increased anthropogenic inputs during non-monsoon times. • Anthropogenic inputs are linked with Indian, South Asian and Central Asian sources

  20. Seasonal variations in the sources of natural and anthropogenic lead deposited at the East Rongbuk Glacier in the high-altitude Himalayas

    Energy Technology Data Exchange (ETDEWEB)

    Burn-Nunes, Laurie, E-mail: L.Nunes@curtin.edu.au [Department of Imaging and Applied Physics, Curtin University, GPO Box U 1987, Perth 6845, Western Australia (Australia); Vallelonga, Paul [Centre for Ice and Climate, Niels Bohr Institute, University of Copenhagen, Juliane Maries Vej 30, DK-2100 Copenhagen Ø (Denmark); Lee, Khanghyun [Environmental Measurement and Analysis Center, National Institute of Environmental Research, Environmental Research Complex, Kyungseo-dong, Seo-gu, Incheon 404-170 (Korea, Republic of); Hong, Sungmin [Department of Ocean Sciences, Inha University, 100 Inha-ro, Nam-gu, Incheon 402-751 (Korea, Republic of); Burton, Graeme [Department of Imaging and Applied Physics, Curtin University, GPO Box U 1987, Perth 6845, Western Australia (Australia); Hou, Shugui [Key Laboratory of Coast and Island development of Ministry of Education, School of Geographic and Oceanographic Sciences, Nanjing University, Nanjing 210093 (China); Moy, Andrew [Department of the Environment, Australian Antarctic Division, Channel Highway, Kingston 7050, Tasmania (Australia); Antarctic Climate and Ecosystems Cooperative Research Centre, University of Tasmania, Private Bag 80, Hobart 7001, Tasmania (Australia); Edwards, Ross; Loss, Robert; Rosman, Kevin [Department of Imaging and Applied Physics, Curtin University, GPO Box U 1987, Perth 6845, Western Australia (Australia)

    2014-07-01

    Lead (Pb) isotopic compositions and concentrations, and barium (Ba) and indium (In) concentrations have been analysed at sub-annual resolution in three sections from a < 110 m ice core dated to the 18th and 20th centuries, as well as snow pit samples dated to 2004/2005, recovered from the East Rongbuk Glacier in the high-altitude Himalayas. Ice core sections indicate that atmospheric chemistry prior to ∼ 1953 was controlled by mineral dust inputs, with no discernible volcanic or anthropogenic contributions. Eighteenth century monsoon ice core chemistry is indicative of dominant contributions from local Himalayan sources; non-monsoon ice core chemistry is linked to contributions from local (Himalayan), regional (Indian/Thar Desert) and long-range (North Africa, Central Asia) sources. Twentieth century monsoon and non-monsoon ice core data demonstrate similar seasonal sources of mineral dust, however with a transition to less-radiogenic isotopic signatures that suggests local and regional climate/environmental change. The snow pit record demonstrates natural and anthropogenic contributions during both seasons, with increased anthropogenic influence during non-monsoon times. Monsoon anthropogenic inputs are most likely sourced to South/South-East Asia and/or India, whereas non-monsoon anthropogenic inputs are most likely sourced to India and Central Asia. - Highlights: • Pb isotopes in ice and snow show seasonality in Mt Everest atmospheric chemistry. • Local (Himalayan) mineral dust inputs are present year round. • Regional and long-range mineral dust inputs are evident during non-monsoon times. • Snow samples indicate increased anthropogenic inputs during non-monsoon times. • Anthropogenic inputs are linked with Indian, South Asian and Central Asian sources.