WorldWideScience

Sample records for determine unknown trace

  1. Age determination of trace plutonium using liquid scintillation counting and α-spectrometry

    International Nuclear Information System (INIS)

    Chen Yan; Chang Zhiyuan; Zhao Yonggang; Li Jinghuai; Shu Fujun

    2010-01-01

    Liquid scintillation counting combined with α-spectrometry through measuring 241 Pu/ 241 Am ratio to determine the age of trace Pu was studied. The technique was explored for the age determination of nanogram grade Pu sample on the basis of Pu/Am separation. The ages of two Pu samples-one with known and the other with unknown age were determined by the method. The determined age by the method is in agreement with the reference value. The established method for determining the age of trace Pu can be adopted in the verification activities of nuclear safeguards and nuclear arms control. (authors)

  2. Determination of the origin of unknown irradiated nuclear fuel.

    Science.gov (United States)

    Nicolaou, G

    2006-01-01

    An isotopic fingerprinting method is presented to determine the origin of unknown nuclear material with forensic importance. Spent nuclear fuel of known origin has been considered as the 'unknown' nuclear material in order to demonstrate the method and verify its prediction capabilities. The method compares, using factor analysis, the measured U, Pu isotopic compositions of the 'unknown' material with U, Pu isotopic compositions simulating well known spent fuels from a range of commercial nuclear power stations. Then, the 'unknown' fuel has the same origin as the commercial fuel with which it exhibits the highest similarity in U, Pu compositions.

  3. Determination of the origin of unknown irradiated nuclear fuel

    International Nuclear Information System (INIS)

    Nicolaou, G.

    2006-01-01

    An isotopic fingerprinting method is presented to determine the origin of unknown nuclear material with forensic importance. Spent nuclear fuel of known origin has been considered as the 'unknown' nuclear material in order to demonstrate the method and verify its prediction capabilities. The method compares, using factor analysis, the measured U, Pu isotopic compositions of the 'unknown' material with U, Pu isotopic compositions simulating well known spent fuels from a range of commercial nuclear power stations. Then, the 'unknown' fuel has the same origin as the commercial fuel with which it exhibits the highest similarity in U, Pu compositions

  4. Photometric determination of traces of metals

    International Nuclear Information System (INIS)

    Onishi, H.

    1986-01-01

    The first three editions of this widely used classic were published under the title Colorimetric Determination of Traces of Metals, with E.B. Sandell as author. Part I (General Aspects) of the fourth edition was co-authored by E.B. Sandell and H. Onishi and published in 1978. After Sandell's death in 1984, Onishi assumed the monumental task of revising Part II. This book (Part IIA) consists of 21 chapters in which the photometric determinations of the individual metals, aluminium to lithium (including the lanthanoids), are described. Each chapter is divided into three sections: Separations, Methods of Determination, and Applications. The sections on Separations are of general interest and include methods based on precipitation, ion-exchange, chromatography, and liquid-liquid extraction. Molecular absorption and fluorescence techniques are described in the sections on determinations, and the emphasis is on the use of well-established reagents. Several reagents that have been recently introduced for the determination of trace levels of metals are also critically reviewed at the end of each section on methods of determination. Important applications of these methods to the determination of trace metals in complex organic and inorganic materials are described in detail at the end of each chapter

  5. Simultaneous Determination of 30 Trace Elements in Cancerous and Noncancerous Human Tissue Samples with Gamma-ray Spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Samsahl, K; Brune, D; Wester, P O

    1963-10-15

    The following trace elements were quantitatively determined by gamma-ray spectrometry in T samples of non-cancerous and 5 samples of cancerous human tissue: P, Ca, Cr, Fe, Co, Cu, Zn, As, Se, Br, Rb, Mo, Ag, Cd, Sb, Cs, La, Au, and Hg. In some of the samples the following elements were qualitatively determined: Ti+Sc, Ga, Sr, In, Ba, Ce, Hf, Os, Pt, and U. Most of the trace elements were found to be present in much higher concentrations in the non-cancerous than in the corresponding cancerous liver samples. In a typical run one sample each of cancerous and non-cancerous tissue was irradiated together with standards of the elements to be determined in a thermal flux of 2.10{sup 13} n/cm{sup 2}/sec. for 24 hours. The radioactive trace elements were separated into 16, and in some cases 18, groups by means of a chemical group separation method. Subsequently, the gamma spectrometric measurements were performed. Two persons can manage the chemical separations and measure the different activities from a run in 1,5 days. A new method of comparing unknown samples with standards was developed.

  6. INAA Application for Trace Element Determination in Biological Reference Material

    Science.gov (United States)

    Atmodjo, D. P. D.; Kurniawati, S.; Lestiani, D. D.; Adventini, N.

    2017-06-01

    Trace element determination in biological samples is often used in the study of health and toxicology. Determination change to its essentiality and toxicity of trace element require an accurate determination method, which implies that a good Quality Control (QC) procedure should be performed. In this study, QC for trace element determination in biological samples was applied by analyzing the Standard Reference Material (SRM) Bovine muscle 8414 NIST using Instrumental Neutron Activation Analysis (INAA). Three selected trace element such as Fe, Zn, and Se were determined. Accuracy of the elements showed as %recovery and precision as %coefficient of variance (%CV). The result showed that %recovery of Fe, Zn, and Se were in the range between 99.4-107%, 92.7-103%, and 91.9-112%, respectively, whereas %CV were 2.92, 3.70, and 5.37%, respectively. These results showed that INAA method is precise and accurate for trace element determination in biological matrices.

  7. Polarographic determination of trace amounts of thorium

    Energy Technology Data Exchange (ETDEWEB)

    Zaofan Zhao; Xiaohua Cai; Peibiao Li; Handong Yang

    1986-07-01

    A sensitive linear-sweep polarographic method for the determination of thorium is described. It is based on the thorium complex with Xylidyl Blue I (XBI) in a medium containing ethylenediamine, 1, 10-phenanthroline, oxalic acid and ninhydrin, at pH 10.5-11.5. The complex has been proved to be Th(XBI)/sub 2/, with log ..beta..'=9.6. The method can be used to determine trace amounts of thorium over the range 3.5x10/sup -8/-3x10/sup -6/M. The detection limit is 1x10/sup -8/M. A solvent extraction procedure is necessary to eliminate interference from several cations. The method has been applied to determination of traces of thorium in minerals, with good results.

  8. Bayesian source term determination with unknown covariance of measurements

    Science.gov (United States)

    Belal, Alkomiet; Tichý, Ondřej; Šmídl, Václav

    2017-04-01

    Determination of a source term of release of a hazardous material into the atmosphere is a very important task for emergency response. We are concerned with the problem of estimation of the source term in the conventional linear inverse problem, y = Mx, where the relationship between the vector of observations y is described using the source-receptor-sensitivity (SRS) matrix M and the unknown source term x. Since the system is typically ill-conditioned, the problem is recast as an optimization problem minR,B(y - Mx)TR-1(y - Mx) + xTB-1x. The first term minimizes the error of the measurements with covariance matrix R, and the second term is a regularization of the source term. There are different types of regularization arising for different choices of matrices R and B, for example, Tikhonov regularization assumes covariance matrix B as the identity matrix multiplied by scalar parameter. In this contribution, we adopt a Bayesian approach to make inference on the unknown source term x as well as unknown R and B. We assume prior on x to be a Gaussian with zero mean and unknown diagonal covariance matrix B. The covariance matrix of the likelihood R is also unknown. We consider two potential choices of the structure of the matrix R. First is the diagonal matrix and the second is a locally correlated structure using information on topology of the measuring network. Since the inference of the model is intractable, iterative variational Bayes algorithm is used for simultaneous estimation of all model parameters. The practical usefulness of our contribution is demonstrated on an application of the resulting algorithm to real data from the European Tracer Experiment (ETEX). This research is supported by EEA/Norwegian Financial Mechanism under project MSMT-28477/2014 Source-Term Determination of Radionuclide Releases by Inverse Atmospheric Dispersion Modelling (STRADI).

  9. Determination of trace elements in drinking tea by various analytical techniques

    International Nuclear Information System (INIS)

    Wang Chufang; Ke Chenghsiung; Yang Jenqyann

    1993-01-01

    Tea has been one of the most popular simulating beverages which is both heavily produced and consumed in Taiwan. The determination of minor or trace elements in drinking tea and tea leaves is therefore important for estimating the daily intake of Taiwanese considered as a safety indicator. In order to accurately and precisely determine the concentrations of trace elements in samples, several analytical methods such as AAS, NAA and ICP-AES are suggested. This paper attempts to utilize all three methods to determine the concentrations of minor or trace elements in different types of tea leaves and the extracts percolated from them. The influence of fermentation processes on the concentration levels of minor or trace elements in tea samples is investigated. Because only free metal ions are bioavailable for the human body, it is necessary to determine their concentrations in drinking tea. The dissolution of trace elements in drinking tea is therefore studied by simulating the common Chinese style of tea percolation. Concentrations of thirteen elements including Zn, Mn, Ca, Cu, Ni, Al, K, Mg, Cd, Pb, Na, Co and Sc are determined. (author) 14 refs.; 1 fig.; 6 tabs

  10. Application of trace element analysis to determine trace element concentrations in the field of medicine

    International Nuclear Information System (INIS)

    Kasperek, K.; Feinendegen, L.E.

    1976-01-01

    Applied trace elements research in medicine requires a sensitive and efficient technique of trace elements analysis such as, e.g., neutron activation analysis. Essential trace elements act as stabilisators (iron in haem), structural elements (silicium in fibrous tissue), in hormones (iodine in thyroid hormone), in vitamins (cobalt in vitamin B 12), and in enzymes. Most of the essential trace elements act as coenzymes or in coenzymes or directly as metabolic catalysators. For example, selenium deficiency in PKU and maple syrup patients receiving dietary treatment can be detected by determining the selenium content of the serum, while low selenium values in the whole blood indicate liver cirrhosis. Acrodermatitis enteropathica can be diagnosed by determinig zinc in the serum, and pancreatic insufficiency by determining zinc in the pancreatic juice. Zinc also plays a part in disturbances of growth, in the healing of wounds, and in the insulin metabolism. Cobalt is important in some types of anaemia and in myocardiopathies. Trace elements are also necessary in the treatment of diseases, e.g. iron cobalt in some types of anaemia, and zinc in the delayed healing of wounds in the postoperative phase and in acrodermatitis enteropathica. Chromium is now being tested for the treatment of diabetes mellitus, and fluorides may be of interest in the treatment of osteoporosis. Finally, trace elements are important in the aetiology of acute poisoning, in nutrition, and in environmental protection. (orig./AK) [de

  11. Application of trace element analysis to determine trace element concentrations in the field of medicine. [Neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Kasperek, K; Feinendegen, L E

    1976-01-01

    Applied trace elements research in medicine requires a sensitive and efficient technique of trace elements analysis, such as neutron activation analysis. Essential trace elements act as stabilizators (iron in haem), structural elements (silicon in fibrous tissue), in hormones (iodine in thyroid hormone), in vitamins (cobalt in vitamin B 12), and in enzymes. Most of the essential trace elements act as coenzymes or in coenzymes or directly as metabolic catalyzers. For example, selenium deficiency in PKU and maple syrup patients receiving dietary treatment can be detected by determining the selenium content of the serum, while low selenium values in the whole blood indicate liver cirrhosis. Acrodermatitis enteropathica can be diagnosed by determinig zinc in the serum, and pancreatic insufficiency by determining zinc in the pancreatic juice. Zinc also plays a part in disturbances of growth, in the healing of wounds, and in the insulin metabolism. Cobalt is important in some types of anaemia and in myocardiopathies. Trace elements are also necessary in the treatment of diseases, e.g. iron cobalt in some types of anaemia, and zinc in the delayed healing of wounds in the postoperative phase and in acrodermatitis enteropathica. Chromium is now being tested for the treatment of diabetes mellitus, and fluorides may be of interest in the treatment of osteoporosis. Finally, trace elements are important in the aetiology of acute poisoning, in nutrition, and in environmental protection.

  12. The separation and determination of trace elements in iron ore

    International Nuclear Information System (INIS)

    Jones, E.A.

    1977-01-01

    The separation, concentration, and determination of trace elements in iron ores are described. After the sample has been dissolved, the iron is separated by liquid-liquid extraction with a liquid cation-exchanger, di-(2-ethylhexyl) phosphoric acid. The trace elements aluminium, cadmium, calcium, chromium, cobalt, copper, lead, magnesium, manganese, mercury, potassium, sodium, vanadium, and zinc are determined in the aqueous phase by atomic-absorption spectrophotometry

  13. Determination of trace elements in airborne particulate matter. Pt. 2

    International Nuclear Information System (INIS)

    Pamuk, F.; Kahraman, N.; Kut, D.

    1975-04-01

    Several trace elements are being introduced into the atmosphere from various sources. Since many of the trace elements are highly toxic, the concentrations of them should be measured and controlled continuously for public health. Concentrations of trace elements have been determined in air samples collected from seven different districts of Ankara by the use of instrumental neutron activation analysis and atomic absorption spectrophotometer. (Pamuk, F.; Kahraman, N.; Kut, D.)

  14. Determination of trace elements in electronic materials by NAA

    International Nuclear Information System (INIS)

    Kobayashi, Kenji

    1986-01-01

    Trace amounts of elements in electronic materials were determined by instrumental neutron activation analysis (INAA), re-activation analysis and substoichiometric radioactivation analysis using gamma-ray spectrometry. Ten elements (Cr, Cu, Fe, Zn, Co, Eu, Ir, Sb, Sc, Tb) in gallium arsenide single crystal were determined by INAA and substoichiometric radioactivation analysis. Trace level of chromium (10 13 atoms/cm 3 ) and zinc (10 14 atoms/cm 3 ) in gallium arsenide single crystal were determined by INAA. The chromium concentrations in horizontal Bridgmangrown semi-insulating gallium arsenide ingot were ranged from 1.2 x 10 16 atoms/cm 3 at seed end to 3.5 x 10 16 atoms/cm 3 at tail end. The trace determinations of iron (10 14 atoms/cm 3 ) and copper (10 14 atoms/cm 3 ) in silicon, gallium arsenide and indium phoshide single crystals were carried out by substoichiometric radioactivation analysis. The reactivation analysis for the multielement determination of indium phosphide single crystal was carried out and nineteen elements were determined simultaneously by gamma-ray spectrometry. Eleven elements (Ag, As, Br, Co, Cr, Fe, K, Mn, Sb, Sc, Zn) in four NIES standard reference materials (Pond Sediment, Chlorella, Mussel and Tea Leaves) and seven elements (Co, Cr, Eu, Fe, Sc, Tb, Yb) in two NBS glasses (SRM-615 and SRM-613) were determined by INAA and substoichiometric radioactivation analysis and the analytical results obtained by the methods were in good agreement with certified values by NIES and NBS. (author)

  15. Spectrographic determination of traces of halogens; Dosage de traces d'halogenes par la methode spectrographique

    Energy Technology Data Exchange (ETDEWEB)

    Melamed, J [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1961-07-01

    Hollow cathode source is employed for determining traces of halogens (fluorine - chlorine) in the uranium oxide U{sub 3}O{sub 8} qualitatively, detection of at least 40 ppm of fluorine, as alkali fluoride and 125 ppm of chlorine, is possible. (author) [French] Un tube a decharge a cathode creuse a ete utilise pour la determination spectrographique des halogenes (fluor - chlore) presentes a l'etat de traces dans un oxyde d'uranium U{sub 3}O{sub 8}. On a pu deceler qualitativement des teneurs de 40 ppm de fluor sous forme de fluorures alcalins. En ce qui concerne le chlore, la plus faible teneur decelee a ete de 125 ppm. (auteur)

  16. Unknown foundation determination for scour.

    Science.gov (United States)

    2012-04-01

    Unknown foundations affect about 9,000 bridges in Texas. For bridges over rivers, this creates a problem : regarding scour decisions as the calculated scour depth cannot be compared to the foundation depth, and a : very conservative costly approach m...

  17. ICP-AES determination of trace elements in carbon steel

    International Nuclear Information System (INIS)

    Sengupta, Arijit; Rajeswari, B.; Kadam, R.M.; Babu, Y.; Godbole, S.V.

    2010-01-01

    Full text: Carbon steel, a combination of the elements iron and carbon, can be classified into four types as mild, medium, high and very high depending on the carbon content which varies from 0.05% to 2.1%. Carbon steel of different types finds application in medical devices, razor blades, cutlery and spring. In the nuclear industry, it is used in feeder pipes in the reactor. A strict quality control measure is required to monitor the trace elements, which have deleterious effects on the mechanical properties of the carbon steel. Thus, it becomes imperative to check the purity of carbon steel as a quality control measure before it is used in feeder pipes in the reactor. Several methods have been reported in literature for trace elemental determination in high purity iron. Some of these include neutron activation analysis, atomic absorption spectrometry and atomic emission spectrometry. Inductively coupled plasma atomic emission spectrometry (ICP-AES) is widely recognized as a sensitive technique for the determination of trace elements in various matrices, its major advantages being good accuracy and precision, high sensitivity, multi-element capability, large linear dynamic range and relative freedom from matrix effects. The present study mainly deals with the direct determination of trace elements in carbon steel using ICP-AES. An axially viewing ICP spectrometer having a polychromator with 35 fixed analytical channels and limited sequential facility to select any analytical line within 2.2 nm of a polychromator line was used in these studies. Iron, which forms one of the main constituents of carbon steel, has a multi electronic configuration with line rich emission spectrum and, therefore, tends to interfere in the determination of trace impurities in carbon steel matrix. Spectral interference in ICP-AES can be seriously detrimental to the accuracy and reliability of trace element determinations, particularly when they are performed in the presence of high

  18. Determination of Trace Concentration in TMD Detectors using PGAA

    Directory of Open Access Journals (Sweden)

    Tomandl I.

    2015-01-01

    Full Text Available Transmutation detectors could be alternative to the traditional activation detector method for neutron fluence dosimetry at power nuclear reactors. This new method require an isotopically highly-sensitive, non-destructive in sense of compactness as well as isotopic content, precise and standardly used analytical method for trace concentration determination. The capability of Prompt Gamma-ray Activation Analysis (PGAA for determination of trace concentrations of transmuted stable nuclides in the metallic foils of Ni, Au, Cu and Nb, which were irradiated for 21 days in the reactor core at the LVR-15 research reactor in Řež, is reported. The PGAA measurements of these activation foils were performed at the PGAA facility at Forschungs-Neutronenquelle Heinz Maier-Leibnitz (FRMII in Garching.

  19. Concentration of 24 Trace Elements in Human Heart Tissue Determined by Neutron Activation Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Wester, P O

    1964-06-15

    By means of neutron-activation analysis, human heart tissue from autopsy of 20 victims of traumatic accidents has been investigated with respect to the concentration of 24 different trace elements. A recently developed ion-exchange technique combined with gamma spectrometry has been used, which permits simultaneous determination of a large number of trace elements. The following trace elements have been determined quantitatively: Ag, As, Au, Ba, Br; Ca, Cd, Ce, Co, Cr, Cs, Cu, Fe, Hg, La, Mo, Pt, Rb, Sb, Se, Se, Sm, Zn, W. In some heart samples, Hf and Os were determined qualitatively. The mean and standard deviation are given for the elements Cu, Fe, Se and Zn, Since none of the other quantitatively determined trace elements were normally distributed, the median is given as the central value. When possible, comparisons with values from other investigations have been made. No marked differences in the trace-element concentrations with age or sex could be detected.

  20. Concentration of 24 Trace Elements in Human Heart Tissue Determined by Neutron Activation Analysis

    International Nuclear Information System (INIS)

    Wester, P.O.

    1964-06-01

    By means of neutron-activation analysis, human heart tissue from autopsy of 20 victims of traumatic accidents has been investigated with respect to the concentration of 24 different trace elements. A recently developed ion-exchange technique combined with gamma spectrometry has been used, which permits simultaneous determination of a large number of trace elements. The following trace elements have been determined quantitatively: Ag, As, Au, Ba, Br; Ca, Cd, Ce, Co, Cr, Cs, Cu, Fe, Hg, La, Mo, Pt, Rb, Sb, Se, Se, Sm, Zn, W. In some heart samples, Hf and Os were determined qualitatively. The mean and standard deviation are given for the elements Cu, Fe, Se and Zn, Since none of the other quantitatively determined trace elements were normally distributed, the median is given as the central value. When possible, comparisons with values from other investigations have been made. No marked differences in the trace-element concentrations with age or sex could be detected

  1. Zeta functions and regularized determinants related to the Selberg trace formula

    DEFF Research Database (Denmark)

    Momeni, Arash; Venkov, Alexei

    determinants of one dimensional Schroedinger operator for harmonic oscillator. We decompose the determinant of the automorphic Laplacian into a product of the determinants where each factor is a determinant representation of a zeta function related to Selberg's trace formula. Then we derive an identity...... connecting the determinants of the automorphic Laplacians on different Riemannian surfaces related to the arithmetical groups. Finally, by using the Jacquet-Langlands correspondence we connect the determinant of the automorphic Laplacian for the unit group of quaternions to the product of the determinants......For a general Fuchsian group of the first kind with an arbitrary unitary representation we define the zeta functions related to the contributions of the identity, hyperbolic, elliptic and parabolic conjugacy classes in Selberg's trace formula. We present Selberg's zeta function in terms...

  2. [Determination and correlation analysis of trace elements in Boletus tomentipes].

    Science.gov (United States)

    Li, Tao; Wang, Yuan-zhong; Zhang, Ji; Zhao, Yan-li; Liu, Hong-gao

    2011-07-01

    The contents of eleven trace elements in Boletus tomentipes were determined by inductively coupled plasma atomic emission spectroscopy (ICP-AES). The results showed that the fruiting bodies of B. tomentipes were very rich in Mg and Fe (>100 mg x kg(-1)) and rich in Mn, Zn and Cu (>10 mg x kg(-1)). Cr, Pb, Ni, Cd, and As were relatively minor contents (0.1-10.0 mg x kg(-1)) of this species, while Hg occurred at the smallest content (< 0.1 mg x kg(-1)). Among the determined 11 trace elements, Zn-Cu had significantly positive correlation (r = 0.659, P < 0.05), whereas, Hg-As, Ni-Fe, and Zn-Mg had significantly negative correlation (r = -0.672, -0.610, -0.617, P < 0.05). This paper presented the trace elements properties of B. tomentipes, and is expected to be useful for exploitation and quality evaluation of this species.

  3. Determination of Sugar and Some Trace Metals Content in Selected ...

    African Journals Online (AJOL)

    Ten brands of commercial fruit juices were analyzed for pH, specific gravity, total solids, reducing sugar and total sugar trace metals contents. The pH was determined using a Hanna pH meter. Sugar content was determined using the Lane and Eynon method. Sodium and potassium were determined by flame photometry ...

  4. Spectrographic Determination of Trace Constituents in Rare Earths

    International Nuclear Information System (INIS)

    Capdevila, C.; Alvarez, F.

    1962-01-01

    A spectrographic method was developed for the determination of 18 trace elements in lanthanum, cerium, praseodimium, neodimium and samarium compounds. The concentrations of the impurities cover the range of 0,5 to 500 ppm. Most of these impurities are determined by the carrier distillation method. Several more refractory elements have been determined by total burning of the sample with a direct current arc or by the conduction briquet excitation technique with a high voltage condensed spark. The work has been carried out with a Hilger Automatic Large Quartz Spectrograph. (Author) 5 refs

  5. Trace conditioning in insects-keep the trace!

    Science.gov (United States)

    Dylla, Kristina V; Galili, Dana S; Szyszka, Paul; Lüdke, Alja

    2013-01-01

    Trace conditioning is a form of associative learning that can be induced by presenting a conditioned stimulus (CS) and an unconditioned stimulus (US) following each other, but separated by a temporal gap. This gap distinguishes trace conditioning from classical delay conditioning, where the CS and US overlap. To bridge the temporal gap between both stimuli and to form an association between CS and US in trace conditioning, the brain must keep a neural representation of the CS after its termination-a stimulus trace. Behavioral and physiological studies on trace and delay conditioning revealed similarities between the two forms of learning, like similar memory decay and similar odor identity perception in invertebrates. On the other hand differences were reported also, like the requirement of distinct brain structures in vertebrates or disparities in molecular mechanisms in both vertebrates and invertebrates. For example, in commonly used vertebrate conditioning paradigms the hippocampus is necessary for trace but not for delay conditioning, and Drosophila delay conditioning requires the Rutabaga adenylyl cyclase (Rut-AC), which is dispensable in trace conditioning. It is still unknown how the brain encodes CS traces and how they are associated with a US in trace conditioning. Insects serve as powerful models to address the mechanisms underlying trace conditioning, due to their simple brain anatomy, behavioral accessibility and established methods of genetic interference. In this review we summarize the recent progress in insect trace conditioning on the behavioral and physiological level and emphasize similarities and differences compared to delay conditioning. Moreover, we examine proposed molecular and computational models and reassess different experimental approaches used for trace conditioning.

  6. Determination of trace elements in cockle Anadara Granosa L. using INAA

    International Nuclear Information System (INIS)

    Ibrahim, Noorddin

    1994-01-01

    This study determines the trace metal content in Anadara Granosa L., a popular seafood amongst South-East-Asians. Using the technique of instrumental neutron activation analysis (INAA) identification has been made of the presence of 17 trace metals including elements which are classified as toxic (As, Br, Cs) and those which are rare-earths (Eu, Ce, Lu, Tb, Yb). (author)

  7. PIXE determination of essential trace elements in some traditional Chinese medicines

    International Nuclear Information System (INIS)

    Xiao, L.; Qin, J.F.

    1990-01-01

    The essential trace elements in 30 traditional Chinese medicines, (24 tonics and 6 nontonics) were determined by proton-induced X-ray emission. The authors' previous suggestion that traditional Chinese medicines may be classified by the order of magnitude of their essential trace elements, thus indicating their pharmacological effects, is not justified. The pharmacological effect of a trace element or its essentiality may be dependent on some ligand that can be chelated with it. A nonlinear mapping algorithm, however, shows that the 30 traditional Chinese medicines are nearly separated into two groups, indicating their tonic or nontonic pharmacological effects

  8. Determination of some trace elements in biological samples using XRF and TXRF techniques

    International Nuclear Information System (INIS)

    Khuder, A.; Karjou, J.; Sawan, M. K.

    2006-07-01

    XRF and TXRF techniques were successfully used for the multi-element determination of trace elements in whole blood and human head hair samples. This was achieved by the direct analysis using XRF technique with different collimation units and by the optimized chemical procedures for TXRF analysis. Light element of S and P were preferably determined by XRF with primary x-ray excitation, while, elements of K, Ca, Fe, and Br were determined with a very good accuracy and precision using XRF with Cu- and Mo-secondary targets. The chemical procedure dependent on the preconcentration of trace elements by APDC was superiorly used for the determination of traces of Ni and Pb in the range of 1.0-1.7 μg/dl and 11-23 μg/dl, respectively, in whole blood samples by TXRF technique; determination of other elements as Cu and Zn was also achievable using this approach. Rb in whole blood samples was determined directly after the digestion of samples using PTFE-bomb for TXRF analysis. (author)

  9. Trace conditioning in insects – Keep the trace!

    Directory of Open Access Journals (Sweden)

    Kristina V Dylla

    2013-08-01

    Full Text Available Trace conditioning is a form of associative learning that can be induced by presenting a conditioned stimulus (CS and an unconditioned stimulus (US following each other, but separated by a temporal gap. This gap distinguishes trace conditioning from classical delay conditioning, where the CS and US overlap. To bridge the temporal gap between both stimuli and to form an association between CS and US in trace conditioning, the brain must keep a neural representation of the CS after its termination – a stimulus trace. Behavioral and physiological studies on trace and delay conditioning revealed similarities between the two forms of learning, like similar memory decay and similar odor identity perception in invertebrates. On the other hand differences were reported also, like the requirement of distinct brain structures in vertebrates or disparities in molecular mechanisms in both vertebrates and invertebrates. For example, in commonly used vertebrate conditioning paradigms the hippocampus is necessary for trace but not for delay conditioning, and Drosophila delay conditioning requires the Rutabaga adenylyl cyclase, which is dispensable in trace conditioning. It is still unknown how the brain encodes CS traces and how they are associated with a US in trace conditioning. Insects serve as powerful models to address the mechanisms underlying trace conditioning, due to their simple brain anatomy, behavioral accessibility and established methods of genetic interference. In this review we summarize the recent progress in insect trace conditioning on the behavioral and physiological level and emphasize similarities and differences compared to delay conditioning. Moreover, we examine proposed molecular and computational models and reassess different experimental approaches used for trace conditioning.

  10. Determination of trace gold in rocks and minerals by neutron activation analysis

    International Nuclear Information System (INIS)

    Zhao Yunlong; Zhou Suqing; Liang Yutang

    1988-05-01

    The determination of trace gold in rocks and minerals by neutron activation analysis is described. Two methods are used for pre-separating and concentrating the trace gold in geological samples. one of the methods is that the samples are dissolved in aqua regia solution; activated carbon paper pulp filter is used for pre-separating and concentrating trace gold by dynamic adsorption method; then the activated carbon containing gold was ashed at 650 ∼ 700 deg c. The other method is that the samples are dissolved in aqua regia solution; the polyurethane foam plastic filled with activated carbon is used for pre-separating and concentrating trace gold by dynamic adsorption method; then the foam plastic containing gold was ashed at 650 deg c. The gold in ashes is determinated by neutron activation analysis. The detection limit is 0.004ng/g. The accuracy of the method is examined by gold in reference standard material. The results of this method are in good agreement with the recommended value. For analysis of the trace gold by the methods of instrumental neutron activation analysis and epithermal neutron activation analysis, the interference of 411.8 keV γ-ray from 153 Sm, 152 Eu and fission products of uranium and the correction methods are discussed

  11. Spectrochemical determination of impurities and noble metal traces in carnallite

    International Nuclear Information System (INIS)

    Goldbart, Z.; Carmi, U.; Harrel, A.

    1978-02-01

    A spectrochemical method was developed for the determination of impurities and noble metal traces in carnallite by DC arc excitation. The investigated sample is brought to a standard form of potassium-magnesium sulphate mixed with graphite. Detection limits of 1-10 ppm were determined for 27 elements; the dynamical detection range is 1-400 ppm

  12. Method to determine trace elements in water samples by neutron activation analysis

    International Nuclear Information System (INIS)

    Kueppers, G.; Erdtmann, G.

    1981-05-01

    For the determination of trace elements in water by neutron activation analysis irradiation porcedures and chemical separation procedures have been developed. Irradiation in melted quarz glass ampoules in the presence of a platinum wire (for recombination of the oxyhydrogen gas produced by radiolysis) proved successfull with different variants of the irradiation methods, as long irradiation periods without pressure build-up could be achieved. Possible falsifications of the analysis results were investigated in detail (losses by absorption on vessel walls etc.). The irradiated samples can be measured directly with a gamma ray spectrometer and from the radionuclides found the trace element contents may be calculated. More sensitive determinations are possible if the radionuclides are chemically separated. Procedures for removing the matrix activities, for the separation of the radionuclides in groups of elements and for the isolation of single elements have been developed. For especially sensitive determination of some elements selective separation procedures for antimony, cadmium, selenium, mercury and uranium have been developed. The analytical procedures described have been applied to trace element determinations in river water, glacier ice and water solutions from technical processes. (orig./RB) [de

  13. Trace determination of uranium in fertilizer samples by total ...

    Indian Academy of Sciences (India)

    Uranium is reported to be present in phosphate fertilizers. The recovery of uranium from the fertilizers is important because it can be used as fuel in nuclear reactors and also because of environmental concerns. For both these activities suitable method of uranium determinations at trace levels in these fertilizers are required.

  14. Trace Elements in Human Myocardial Infarction Determined by Neutron Activation Analysis

    International Nuclear Information System (INIS)

    Wester, P.O.

    1965-05-01

    By means of neutron activation analysis, injured and adjacent uninjured human heart tissue from 12 autopsy cases with myocardial infarction are investigated with respect to the concentration of 23 trace elements. The bulk elements K, Na and P are also determined. A recently developed ion-exchange technique, combined with subsequent y-spectrometry, is used. The following trace elements are determined: Ag, As, Au, Ba, Br, Ca, Cd, Ce, Co, Cr, Cs, Cu, Fe, Hg, La, Mo, Rb, Sb, Sc, Se, Sm, Zn and W. In the injured tissue compared to the uninjured, calculation on a wet weight basis showed a decrease in Co, Cs, K, Mo, P, Rb and Zn, and an increase in Br, Ca, Ce, La, Na, Sb and Sm. The differences in Ca, La, Mo, P and Zn are dependent on the age of the myocardial infarction, and the regression lines for these elements are given. The concentration of the trace elements in uninjured tissue from infarcted hearts is compared to the concentration of these elements in normal heart tissue, determined in a previous study. In the uninjured tissue from infarcted hearts a decrease is found in Cu and Mo, and an increase in As and Ce

  15. Trace Elements in Human Myocardial Infarction Determined by Neutron Activation Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Wester, P O

    1965-05-15

    By means of neutron activation analysis, injured and adjacent uninjured human heart tissue from 12 autopsy cases with myocardial infarction are investigated with respect to the concentration of 23 trace elements. The bulk elements K, Na and P are also determined. A recently developed ion-exchange technique, combined with subsequent y-spectrometry, is used. The following trace elements are determined: Ag, As, Au, Ba, Br, Ca, Cd, Ce, Co, Cr, Cs, Cu, Fe, Hg, La, Mo, Rb, Sb, Sc, Se, Sm, Zn and W. In the injured tissue compared to the uninjured, calculation on a wet weight basis showed a decrease in Co, Cs, K, Mo, P, Rb and Zn, and an increase in Br, Ca, Ce, La, Na, Sb and Sm. The differences in Ca, La, Mo, P and Zn are dependent on the age of the myocardial infarction, and the regression lines for these elements are given. The concentration of the trace elements in uninjured tissue from infarcted hearts is compared to the concentration of these elements in normal heart tissue, determined in a previous study. In the uninjured tissue from infarcted hearts a decrease is found in Cu and Mo, and an increase in As and Ce.

  16. Determination of trace elements in urban airborne particulates (PM ...

    African Journals Online (AJOL)

    Assessment of the air quality in Newcastle upon Tyne, UK was performed by determining the trace element content in airborne particulates (PM10). Samples were collected over a 12 month period (March 2011 to April 2012) using two high volume air sampler provided with a PM10 size selective inlet. The concentrations of ...

  17. Characterization of prehistoric pottery from the Tremiti Isles by trace elements determination

    International Nuclear Information System (INIS)

    Brandone, A.; Fumo, P.; Giacco, M.; Oddone, M.; Riganti, V.; Baldi, M

    1993-01-01

    The potteries found on the Tremiti Isles (Italy, Adriatic Sea) have been characterized through their trace elements content. The goal of the work was to find out the number of ore deposits that supplied the clay used to manufacture the pottery. Neutron activation analysis has been employed for trace elements content determinations; the results have been statistically evaluated, clusterized and discussed. (author) 13 refs.; 1 fig.; 3 tabs

  18. Determination of trace elements in maifanite by outer cover electrode atomic emission spectrometry

    Institute of Scientific and Technical Information of China (English)

    LI Jianqiang; LU Yiqiang; JIANG Wei

    2005-01-01

    Maifanite is a nature medicinal stone used in many fields for long time. The research on it showed that there are many trace elements in maifanite. In this paper, 36 trace elements in maifanite were determined by outer cover electrode atomic emission spectrometry, and the determination conditions were studied systematically. The results show that the concentrafions of elements, which are beneficial to human health, are higher, and the elements harmful to people health such as As, Cd, Hg, Cr, and Pb are tiny in maifanite. The precision and the accuracy were also discussed.

  19. Problems of determination of principle of psychological profile of unknown criminal person in investigational activity

    Directory of Open Access Journals (Sweden)

    Galina Getman

    2017-03-01

    By the author of the article of analysis different determinations of «psychological profile of unknown criminal person» were subjected. They are set positive lines and separate positions that in opinion of author are not expedient and important are subjected to criticism. That is why, the author points in conclusions the argued positions in relation to the necessity of the use of psychological profile of  unknown criminal person during investigation of criminal realizations in activity of investigator.

  20. Report on intercomparison IAEA/W-4 of the determination of trace elements in simulated fresh water

    International Nuclear Information System (INIS)

    Pszonicki, L.; Hanna, A.N.; Suschny, O.

    1985-05-01

    The report presents results of a laboratory intercomparison on the determination of trace elements in simulated fresh water. 20 trace elements were analyzed by 38 laboratories from 21 countries. The results of the reported comparison confirm the agreement of the nominal concentration values of trace elements in the IAEA/W-4 simulated fresh water with the determined values of these elements. They also confirm that concentrated solutions of this type can be stored in quartz ampoules without any noticeable changes due to the adsorption of trace components on the quartz wall of vessels for considerable time. The concentration values of trace elements could be certified and the material IAEA/W-4 simulated fresh water issued as a reference material. 84% of all results were obtained either by atomic absorption or by atomic emission spectroscopy

  1. Structure Determination of Unknown Organic Liquids Using NMR and IR Spectroscopy: A General Chemistry Laboratory

    Science.gov (United States)

    Pavel, John T.; Hyde, Erin C.; Bruch, Martha D.

    2012-01-01

    This experiment introduced general chemistry students to the basic concepts of organic structures and to the power of spectroscopic methods for structure determination. Students employed a combination of IR and NMR spectroscopy to perform de novo structure determination of unknown alcohols, without being provided with a list of possible…

  2. Trace elements in Turkish tobacco determined by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Gulovali, M.C.

    1977-01-01

    This study was undertaken to determine the concentration of trace elements in nine different brands of Turkish cigarette tobacco, pipe tobacco and tobacco ash. Instrumental neutron activation analysis was employed, and a gamma-ray spectrometer consisting of 40 cm 3 Ge(Li) detector coupled to 1024 and 4096-channel analyzers were used. Samples were irradiated at a thermal neutron flux of about 10 13 cm -2 sec -1 . Concentrations of Na, K, Sc, Cr, Fe, Co, Zn, As, Se, Br, Rb, Sb, Cs, Ba, La, Ce, Eu, Hf, Hg and Th were determined in tobacco and ash; percent transference of these elements into ash were calculated. It was found out that trace elements in cigarette tobacco are left in the ash but only a small percentage is transferred into the smoke

  3. Kinetic Spectrophotometric Determination of Trace Amounts of Sulfide

    Energy Technology Data Exchange (ETDEWEB)

    Barzegar, Mohsen [Tarbiat Modarres University, Tehran (Iran, Islamic Republic of); Jabbari, Ali [K. N. Toosi University, Tehran (Iran, Islamic Republic of); Esmaeili, Majid [Razi University, Kermanshah (Iran, Islamic Republic of)

    2003-09-15

    A method for the determination of trace amount of sulfide based on the addition reaction of sulfide with methyl green at pH 7.5 and 25 .deg. C is described. The reaction is monitored spectrophotometrically by measuring the decrease in absorbance of the dyestuff at 637 nm by the initial rate and fixed time method. The calibration graph is linear in the range 30-1200 ppb. The theoretical limit of detection was 0.014 ppm. Seven replicate analysis of a sample solution containing 0.70 ppm sulfide gave a relative standard deviation of 1.5%. The interfering effects of various ions on sulfide determination have been reported and procedures for removal of interference have been described. The proposed method was applied successfully to the determination of sulfide in tap and wastewater samples.

  4. Kinetic Spectrophotometric Determination of Trace Amounts of Sulfide

    International Nuclear Information System (INIS)

    Barzegar, Mohsen; Jabbari, Ali; Esmaeili, Majid

    2003-01-01

    A method for the determination of trace amount of sulfide based on the addition reaction of sulfide with methyl green at pH 7.5 and 25 .deg. C is described. The reaction is monitored spectrophotometrically by measuring the decrease in absorbance of the dyestuff at 637 nm by the initial rate and fixed time method. The calibration graph is linear in the range 30-1200 ppb. The theoretical limit of detection was 0.014 ppm. Seven replicate analysis of a sample solution containing 0.70 ppm sulfide gave a relative standard deviation of 1.5%. The interfering effects of various ions on sulfide determination have been reported and procedures for removal of interference have been described. The proposed method was applied successfully to the determination of sulfide in tap and wastewater samples

  5. XRF determination of trace and major elements using a single-fused disc

    International Nuclear Information System (INIS)

    Thomas, I.R.; Haukka, M.T.

    1978-01-01

    A new fusion method using lithium metaborate, suitable for the determination of major and trace elements by X-ray fluorescence analysis (XRF), has proven to be of comparable accuracy to other XRF methods for the ten major rock-forming oxides. The very low dilution allows determination of trace elements with a decrease in sensitivity of about a factor of 2 compared with XRF determination using pressed-powder pellets. A feature of the method is the flexibility of sample preparation allowed: the matrix-correction parameters may be used for a wide range of dilutions (sample/flux ratios), no 'Loss' correction is necessary, and imperfect or inhomogeneous discs may be crushed and pressed pellets made of the glass powder when required. Considerable savings in the time during preparation, analysis and correction of results are possible with current automation because of streamlining procedures

  6. The Determination Of Trace Element Levels In Diet By Neutron Activation Analysis

    International Nuclear Information System (INIS)

    Kukuh, Ratnawati; Djojosubroto, Harjoto

    2002-01-01

    Trace element levels in foodstuff are normally low. Although the levels are low, certain trace elements which are called essential trace elements have an important role in metabolism process. Deficiency or intoxication of essential trace elements may lead to abnormal health. In this study the levels of Zn, Fe, AI, Mn, and Co in diet samples were determined by neutron activation analysis, and then the daily intakes of these elements were estimated. The samples were prepared by duplicate diet method, representing those that were consumed by population from West, Central and East Java. Following the collection the respective samples were blended, then were freeze dried at-54 o c. The elemental quantification were performed by neutron activation analysis. The traceability of the determination was ensured using standard reference material NIST-SRM-1548a. The results show that the daily intake for Zn were 2.8-22.8 mg/day (reference value were 5- 40 mg/day), Fe were 3.1-26.5 mg/day (reference value were 6-40 mg/day), AI were 4,2-32.9 mg/day (reference value were 2-45 mg/day), Mn were 1.0-5,6 mg/day (reference value were 0.4-10,0 mg/day), and Co were 0,005-0,074 mg/day (reference value were 0.005 -1.8 mg/day

  7. Determination of Trace Elements in Thai Cereal

    International Nuclear Information System (INIS)

    Permnamtip, Vorapot; Busamongkol, Arporn; Laoharojanaphand, Sirinart; Chaiyasith, Suwan

    2007-08-01

    Full text: Trace elements were analyzed in Thai cereal, e.g. rice and bean, by using neutron activation analysis (NAA). The selected cereals are major food items for Thai population. The data obtained from this work will be useful for nutrition and safety consumption of Thai cereal. Trace elements verified include Al, As, Br, Ca, Cd, Cl, Cr, Cu, Fe, I, K, Mg, Mn, Mo, Se, Sn, V and Zn. It was found that Al, As, Br, Cl, Cu, Fe, Mn, Zn, Ca, K and Mg are presented in the range of 2.2 to 35.7, 0.15 to 0.21, 0.44 to 13.5, 55.6 to 640.3, 16.3 to 16.5, 158.9 to 161.1, 12.2 to 55.7, 8.2 to 58.1 (g/g (ppm) , 0.02 to 0.28, 0.09 to 1.99 and 0.03 to 0.26 %, respectively. For Cd, Cr, I, Mo, Se, Sn and V were not found in sample because the concentrations were lower than detection limit. Precision and accuracy were determined by analyzing standard reference materials: NIST 1568a, NIST 8704, ACSP DORM-1, NIES No.9 and NMIJ 7302 to a

  8. Determination of trace Np and Pu by ICP-MS with extraction chromatography in emergency situations

    International Nuclear Information System (INIS)

    Yanqin, Ji; Qing, Tian; Baoming, Shen; Xianzhang, Shao

    2008-01-01

    Full text: An accurate determination of radioculides from various sources in the environmental samples is essential for assessment of the potential hazards and suitable countermeasures both in case of accidents, authorised release and routine surveillance. However, the concentrationof neptunium and plutonium is extremely low in environmental samples, and such samples have a complex matrix composition, which is to be taken into account for a proper analysis. Conventional radiochemical methods such as alpha spectrometry, neutron activation analysis, liquid, liquid scintillation system, fission track and gamma spectrometry for the quantitative determination of neptunium and plutonium often require complicated and time-consuming sample preparation and separation procedures. Due to the large amount of the complex and often unknown matrix, the analysis may also be covered by naturally occurring radionuclides. With the development of new analysis techniques, non-radioactive methods are increasingly used for the determination of trace or ultra-trace radionuclides in environmental samples. Inductively coupled plasma mass spectrometry (ICP-MS) is one of the most suitable analysis techniques for the measurement of the long-lived radionuclides with its high sensitivity, low detection limits, short analysis time, less chemical interferences and multi-elemental capability. The throughput is therefore very high (approx.100 samples a day). The main objective of the present study was to set up of a simple, fast separation procedure to measure Np and Pu in the environmental samples ICP-MS. An unique extraction chromatographic column (TOA: tri-n-octylamine on Teflon powder) with a two-stage sample loading was prepared to separate Np and Pu from the environmental matrix. Np and Pu were efficiently retained in 4 M HNO 3 medium on the column and easiy eluted with 0.02 M oxalic acid 0.16 M HNO 3 at 95 C degree. The separated solutions were free from most of the matrix elements and were

  9. The Determination of Uranium and Trace Metal Impurities in Yellow Cake Sample by Chemical Method

    International Nuclear Information System (INIS)

    Busamongkol, Arporn; Rodthongkom, Chouvana

    1999-01-01

    The purity of uranium cake is very critical in nuclear-grade uranium (UO 2 ) and uranium hexafluoride (UF 6 ) production. The major element in yellow cake is uranium and trace metal impurities. The objective of this study is to determine uranium and 25 trace metal impurities; Aluminum, Barium, Bismuth, Calcium, Cadmium, Cobalt, Chromium, Copper, Iron, Potassium, Iithium, Magnesium, Manganese, Molybdenum, Sodium, Niobium, Nickel, Lead, Antimony, Tin, Strontium, Titanium, Vanadium, Zinc and Zirconium, Uranium is determined by Potassium dichromate titration, after solvent extraction with Cupferon in Chloroform, Trace metal impurities are determined by solvent extraction with Tributyl Phosphate in Carbon-tetrachloride ( for first 23 elements) and N-Benzoyl-N-Phenylhydroxylamine in Chloroform ( for last 2 elements), then analyzed by Atomic Absorption Spectrophotometer (AAS) compared with Inductively Couple Plasma Spectrophotometers (ICP). The accuracy and precision are studied with standard uranium octaoxide

  10. [Determination of polysaccharide from Chinese medicine Morinda officinalis how and its trace elements analysis].

    Science.gov (United States)

    Wu, Yong-Jun; Liu, Jie; Wu, Yu-Ming; Liu, Li-E; Zhang, Hong-Quan

    2005-12-01

    Polysaccharide was extracted from morinda officinalis how by back-flowing with 80% ethanol for 1 h, and the method of improved phenol-sulfuric acid spectroscopy was adopted to determine the content of morinda officinalis how polysaccharide. As for its trace elements, the atomic absorption spectroscopy was used to detect the content of Zn, Fe and Cu, which were compared with its fake; and cold atomic fluorometry was applied to determine the trace mercury. The results were satisfactory, which can give reference about the effective components of morinda officinalis how, and will help to exploit it.

  11. Determination of trace elements in seawater using Mg-scavenger as preconcentration agent, and neutron activation analysis

    International Nuclear Information System (INIS)

    Andersen, B.

    1986-01-01

    In order to determine trace elements in seawater, a preconsentration method based on coprecipitation on Mg(OH) 2 is presented. Different parameters influencing the carrying effects have been investigated using model solutions and radioactive tracers. The deposit and solution are separated by filtration. Filter with deposit is stored in quarts ampules for later determination of trace elements by means of neutron activation analysis

  12. Indirect Spectrophotometric Determination of Trace Quantities of Hydrazine

    Energy Technology Data Exchange (ETDEWEB)

    Shabani, A. M. Haji; Dadfarnia, S.; Dehghan, K. [Yazd University, Yazd (Iran, Islamic Republic of)

    2004-02-15

    An indirect, sensitive and accurate method for the determination of trace amounts of hydrazine is described. The method is based on the oxidation of hydrazine by a known excess of iodate in the presence of hydrochloric acid. The unreacted iodate is used in the oxidation of hydroxylamine to nitrite. Sulfanilic acid is diazotized by the nitrite formed. The resulting diazonium ion is coupled with N-(1-naphthyl)ethylenediamine to form a stable azo dye, which shows an absorption maximum at 540 nm. Hydrazine can be determined in the range of 20-400 ng mL{sup -1} with a detection limit of 3.1 ng mL{sup -1}. The relative standard deviation for 50, 200 and 400 ng mL{sup -1} of hydrazine is 2, 1.5 and 1.3%, respectively (n = 10). The method was applied to the determination of hydrazine in water samples

  13. Trace element impurity determination in aspirin tablets by INAA

    International Nuclear Information System (INIS)

    Miyoshi, E.K.; Saiki, M.

    2009-01-01

    Instrumental neutron activation analysis (INAA) was applied to assess trace element concentrations in six samples of aspirin tablets acquired in Sao Paulo city, Brazil. Concentrations of the elements Br, Ca, Co, Cr, Fe, K, La, Na, Sc and Zn were determined. Comparisons were made between the results obtained with published data for aspirins from foreign countries. Certified reference materials, INCT-MPH-2 Mixed Polish Herbs were analyzed for quality control of the analytical results. (author)

  14. A new method for determination of trace amount thorium-spectrophotometric determination of thorium in aqueous phase by chlorophosphonazo-mA

    International Nuclear Information System (INIS)

    Xia Yuanxian; Qian Hesheng

    1986-01-01

    In this paper the spectrophotometric method for determination of trace amount of thorium in weak acidic medium by chlorophosphonazo-mA is described. The composition of the complex was estimated to be 1:4 by slope ratio method. The apparent molar absorption of thorium at 675 nm is 9.2 x 10 4 . Beer's law is obeyed for 0-12.0 μg of thorium in 10 ml solution. The coefficient of variation for thorium is 0.88%. The method has been applied to the determination of trace amounts of thorium in the extraction process of thorium

  15. Trace elements in Turkish tobacco determined by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Guelovali, M.C.; Guenduez, G.

    1983-01-01

    The concentration of 20 trace elements in nine brands of Turkish cigarette tobacco and in a brand of pipe tobacco ash has been determined by instrumental neutron activation analysis. The percent transference of elements into smoke has been estimated from the amounts remaining in the ash. (author)

  16. Determination of trace elements in cigarette and tobacco by neutron activation analysis

    International Nuclear Information System (INIS)

    Nouchpramool, S.

    1988-01-01

    The objective of this work is to determine the concentration of 22 trace elements in cigarette and tobacco by instrumental neutron activation analysis in which multielements can be analyzed simultaneously with high sensitivity and reliability as well as easy and rapid. It is well known that, trace toxic elements with high concentration may be harmful for health of smokers. Since they might damage the respiratory system and might cause other diseases. The finding for this report can be used as the basis of further study on toxic of trace elements to the smoker. The results of this analysis show that the bromine content in all samples is significantly high, but the concentration of the other elements are varying from one to another. Bromine concentration might come from soil and/or smoked tobacco leaves with methyl bromide as fungicide

  17. Determination of trace arsenic on hanging copper amalgam drop electrode.

    Science.gov (United States)

    Piech, Robert; Baś, Bogusław; Niewiara, Ewa; Kubiak, Władysław W

    2007-04-30

    Hanging copper amalgam drop electrode has been applied for trace determination of arsenic by cathodic stripping analysis. Detection limit for As(III) as low as 0.33nM (0.02mug/L) at deposition time (240s) could be obtained. For seven successive determinations of As(III) at concentration of 5nM relative standard deviation was 2.5% (n=7). Interferences from selected metals and surfactant substances were examined. Absence of copper ions in sample solution causes easier optimization and makes method less vulnerable on contamination. The developed method was validated by analysis of certified reference materials (CRMs) and applied to arsenic determinations in natural water samples.

  18. Determination of trace amount of formaldehyde base on a bromate-Malachite Green system.

    Science.gov (United States)

    Tang, Yufang; Chen, Hao; Weng, Chao; Tang, Xiaohui; Zhang, Miaoling; Hu, Tao

    2015-01-25

    A novel catalytic kinetic spectrophotometric method for determination of trace amount of formaldehyde (FA) has been established, based on catalytic effect of trace amount of FA on the oxidation of Malachite Green (MG) by potassium bromate in presence of sulfuric acid medium, and was reported for the first time. The method was monitored by measuring the decrease in absorbance of MG at 617 nm and allowed a precise determination of FA in the range of 0.003-0.08 μg mL(-1), with a limit of detection down to 1 ng mL(-1). The relative standard deviation of 10 replicate measurements was 1.63%. The method developed was approved to be sensitive, selective and accurate, and adopted to determinate free FA in samples directly with good accuracy and reproducibility. Copyright © 2014 Elsevier B.V. All rights reserved.

  19. Determination of trace elements in chicken feeds in Khartoum state

    International Nuclear Information System (INIS)

    Hassan, Salma Yahya Mohammed

    2017-03-01

    Trace elements are very important for chicken because thy contribute in biochemical processes required for normal growth, development and formation of the eggshell. The deficiency or the elevation of these trace elements may affect the normal physiological activity and biochemical process of their bodies. In this study the concentrations of trace elements in chicken feed samples were determined by X RF spectrometry. The results showed that there were 9 trace elements in sample ( K, Ca Mn, Fe Cu Zn, Pb, Rb, Sr) the mean concentration were K ( 2.12 x 10 4 ), Ca (2.22x10 4 ), Mn (48.1). Fe (191), Cu(9.81), Zn (24.6), Pb (1.63), Rb (7.79), Sr(4.09) ppm. Comparing the trace elements concentrations obtained in this study with the recommended values showed that some of them e.g Mn, Cu, Zn, Fe were found higher concentration than the recommended values, which stipulated by national research council NRC European Union. While lead concentration was in the permissible limit (5mg/kg). However, the statistical Alan's revealed than there were no significant difference between all concentrations of trace elements in the two types of chicken feeds i.e layer and broiler. The pearson correlation test displayed a strong correlation between K-Rb (0.885), Mn-Zn (0.874). The negative correlation between Mn-Rb (0.680), K-Mn (0.6000), K-Ca (0.565), Zn-Rb (-0.541). Ca-Rb (0.458) were found . Further investigations were performed using the principal component analysis (PCA) which involved the extraction of principal factor to study the total variance in the feed samples in terms of the trace elements concentrations in each. The obtained results revealed that the first principal component have a positive correlation with the elements Ca, Mn, Pb, and Zn, while K and Rb showed negative correlation with it. Similarly, the second principal compound showed positive correlation with the elements Mn, PB and Zn, while Ca and Sr showed negative, on the perth hand the third component was found to

  20. Determination of the trace TBP in industrial feed liquid by gas chromatography

    International Nuclear Information System (INIS)

    Gao Yuehua; Jiang Junqing; Mu Ling; Yang Songtao

    2012-01-01

    The determination of the trace TBP in kerosene of the industrial feed liquid by gas chromatography is studied in the paper. It first takes the purification treatment for the kerosene containing trace TBP. The plutonium is removed by 0.2 mol/L ferrous sulfamate-1 mol/L nitric acid using the back-extraction. The uranium and the nitric acid in the organic phase are removed by the deionized water. The impurity which affect the measurement of the TBP and is harmful to the gas chromatograph are eliminated. Then the content of the TBP of the organic phase can be determined by gas chromatography. Results show that the measuring range of the content of the TBP is 0.02% ∼ 2%. The precision of the method is better than 5% and the recovery is between 95%∼106%. (authors)

  1. The quantitative determination of trace elements in giant unicellular plants by particle-induced X-ray emission

    International Nuclear Information System (INIS)

    Navarrete-Dominguez, V.R.; Yoshihara, K.; Tanaka, N.

    1982-01-01

    Particle-induced X-ray emission (PIXE) was applied for the determination of trace elements in biologically interesting materials, giant unicellular plants. It was found that the PIXE method had advantages in multi-element trace analysis of a single cell of the sample plant. (author)

  2. Influence of trace aromatics on the chemical growth mechanisms of Titan aerosol analogues

    Science.gov (United States)

    Gautier, Thomas; Sebree, Joshua A.; Li, Xiang; Pinnick, Veronica T.; Grubisic, Andrej; Loeffler, Mark J.; Getty, Stephanie A.; Trainer, Melissa G.; Brinckerhoff, William B.

    2017-06-01

    The chemical structure and formation pathways of Titan aerosols remain largely unknown. In this work, we studied the effect of trace aromatics on the chemical composition and formation pathways of laboratory analogues of Titan's organic aerosols. The aerosol analogues were produced using four different trace aromatic molecules, comprised of one or two aromatic rings, each with or without a nitrogen heteroatom. Samples were then analyzed by laser desorption/ionization Mass Spectrometry (LDMS), revealing a high variability in the sample composition depending on the trace aromatic used. Our work reveals that the final chemical structure of the aerosols depends strongly on the number of aromatic rings in the trace molecule, leading either to a polymeric or to a random co-polymeric growth of the sample. These different chemical structures can affect the physical properties of the aerosol. Future analysis of Titan's aerosols using better resolution could potentially determine whether either of the growth hypotheses are preferred.

  3. Chronocoulometric determination of trace levels of uranium in rocks

    International Nuclear Information System (INIS)

    Cantagallo, M.I.C.; Gutz, I.G.R.

    1990-01-01

    The chronocoulometric method for the determination of trace levels of uranium, based on the catalytic nitrate reduction was applied with real and synthetic samples. Reference materials with complex matrices like rocks were first solubilized by hot digestion under pressure in a PTFE bomb. When necessary, an adapted liquid-liquid extraction procedure was used for previous separation of interferents. The obtained results are in good agreement with the values obtained with other techniques such as X-ray fluorescence, mass spectrometry -isotope dilution and apithermal activation analysis. (author) [pt

  4. Taming the unknown a history of algebra from antiquity to the early twentieth century

    CERN Document Server

    Katz, Victor J

    2014-01-01

    What is algebra? For some, it is an abstract language of x's and y's. For mathematics majors and professional mathematicians, it is a world of axiomatically defined constructs like groups, rings, and fields. Taming the Unknown considers how these two seemingly different types of algebra evolved and how they relate. Victor Katz and Karen Parshall explore the history of algebra, from its roots in the ancient civilizations of Egypt, Mesopotamia, Greece, China, and India, through its development in the medieval Islamic world and medieval and early modern Europe, to its modern form in the early twentieth century. Defining algebra originally as a collection of techniques for determining unknowns, the authors trace the development of these techniques from geometric beginnings in ancient Egypt and Mesopotamia and classical Greece. They show how similar problems were tackled in Alexandrian Greece, in China, and in India, then look at how medieval Islamic scholars shifted to an algorithmic stage, which was further dev...

  5. Determination of trace elements in biological material by neutron activation analysis

    International Nuclear Information System (INIS)

    Tran Van, L.; Teherani, D.K.

    1989-01-01

    Eighteen trace elements in biological materials [grass (Imperata cylindrica), mimosa plant (Mimosa pudica), rice] by neutron activation method were determined. In the comparative analysis the content of the same element was different in each material, although they were collected at the same place and the same sampling method was applied. (author) 4 refs.; 1 fig.; 1 tab

  6. Kinetic method of determination of rhodium trace amounts

    International Nuclear Information System (INIS)

    Kalinina, V.E.; Lyakushina, V.M.; Rybina, A.E.

    1978-01-01

    A catalytic action of rhodium compounds has been detected and studied in the reaction of copper (2) tellurate oxidation with hypobromite to ditelluratocuprate (3) in an alkaline medium. The relationships between the reaction rate and concentrations of copper, tellurate, and hypobromite have been established. The optimum concentrations of the used compounds have been found: Csub(Cu(2))=4x10 -5 g-ion/l; Csub(OHsup(-))=3.0 g-ion/l; Csub(Te)=1.4x10 -2 g-ion/l; Csub(NaBrO)=2.17x10 -3 M. It has been established for chloride, sulphate, and perchlorate solutions of rhodium (3) and (4) that the reaction sensitivity increases by 2-3-fold with a temperature rise from 25-60 deg C. The technique of determining rhodium traces has been developed based on its catalytic action. The low limit of determined rhodium amounts is about 10 -3 mkg/ml

  7. Nanomolar Trace Metal Analysis of Copper at Gold Microband Arrays

    Science.gov (United States)

    Wahl, A.; Dawson, K.; Sassiat, N.; Quinn, A. J.; O'Riordan, A.

    2011-08-01

    This paper describes the fabrication and electrochemical characterization of gold microband electrode arrays designated as a highly sensitive sensor for trace metal detection of copper in drinking water samples. Gold microband electrodes have been routinely fabricated by standard photolithographic methods. Electrochemical characterization were conducted in 0.1 M H2SO4 and found to display characteristic gold oxide formation and reduction peaks. The advantages of gold microband electrodes as trace metal sensors over currently used methods have been investigated by employing under potential deposition anodic stripping voltammetry (UPD-ASV) in Cu2+ nanomolar concentrations. Linear correlations were observed for increasing Cu2+ concentrations from which the concentration of an unknown sample of drinking water was estimated. The results obtained for the estimation of the unknown trace copper concentration in drinking was in good agreement with expected values.

  8. Nanomolar Trace Metal Analysis of Copper at Gold Microband Arrays

    International Nuclear Information System (INIS)

    Wahl, A; Dawson, K; Sassiat, N; Quinn, A J; O'Riordan, A

    2011-01-01

    This paper describes the fabrication and electrochemical characterization of gold microband electrode arrays designated as a highly sensitive sensor for trace metal detection of copper in drinking water samples. Gold microband electrodes have been routinely fabricated by standard photolithographic methods. Electrochemical characterization were conducted in 0.1 M H 2 SO 4 and found to display characteristic gold oxide formation and reduction peaks. The advantages of gold microband electrodes as trace metal sensors over currently used methods have been investigated by employing under potential deposition anodic stripping voltammetry (UPD-ASV) in Cu 2+ nanomolar concentrations. Linear correlations were observed for increasing Cu 2+ concentrations from which the concentration of an unknown sample of drinking water was estimated. The results obtained for the estimation of the unknown trace copper concentration in drinking was in good agreement with expected values.

  9. Selenium and Trace Element Distribution in Astragalus Plants: Developing a Differential Pulse Polarographic Method for Their Determination

    OpenAIRE

    SOMER, Güler; ÇALIŞKAN, A. Cengiz

    2007-01-01

    Astragalus plants have a wide range of applications in pharmaceuticals (gum tragacanth), as thickening agents in foods, and may have applications in controlling cancer cells. They are used as feed for animals and they are indicator plants for selenium. Because of their use in health-related areas it is very important to determine their selenium and trace element content with high accuracy. A new differential pulse polarographic method was established for trace element determination (...

  10. Determination of trace amounts of boron in steel by high frequency plasma torch spectrometry

    International Nuclear Information System (INIS)

    Akiyoshi, Takanori; Tsukamoto, Takako

    1978-01-01

    Trace amount of boron in steel were determined by means of emission spectrometry using high frequency plasma torch. The sensitivity of this method depended on the kind of solvent used, and methyl alcohol gave the best sensitivity. The determination limit of boron in methanol was 0.002 μg/ml. The established method utilized the high sensibility of the plasma torch and the easy distillation of boron in methanol as trimethyl-borate (B(OCH 3 ) 3 ). The sample was dissolved by acids and dehydrated by hot H 2 SO 4 and H 3 Po 4 . After cooling and addition of methanol (60 ml), the solution was distilled to obtain 40 ml of the distillate. The amount of boron in the distillate was determined by the intensity of the spectral line of B 2497.73 A excited by plasma torch. This method was rapid and accurate, particularly in determining trace amounts of boron and the determination range of boron in steel was 0.2 to 150 ppm. This method was also appliciable to stainless steels and other alloys. (auth.)

  11. Determination of trace element mineral/liquid partition coefficients in melilite and diopside by ion and electron microprobe techniques

    Science.gov (United States)

    Kuehner, S. M.; Laughlin, J. R.; Grossman, L.; Johnson, M. L.; Burnett, D. S.

    1989-01-01

    The applicability of ion microprobe (IMP) for quantitative analysis of minor elements (Sr, Y, Zr, La, Sm, and Yb) in the major phases present in natural Ca-, Al-rich inclusions (CAIs) was investigated by comparing IMP results with those of an electron microprobe (EMP). Results on three trace-element-doped glasses indicated that it is not possible to obtain precise quantitative analysis by using IMP if there are large differences in SiO2 content between the standards used to derive the ion yields and the unknowns.

  12. Application of neutron activation analysis to trace elements determinations in lung samples

    International Nuclear Information System (INIS)

    Rogero, S.O.

    1991-01-01

    The purpose of this work was to apply the instrumental neutron activation analysis method to determine trace elements in lung samples from smokers and non smokers. Samples of lung tissues and lymph nodes from pulmonary hilum analyzed were collected from autopsies by researchers from Faculdade de Medicina da USP. (author)

  13. Determination of 11 trace elements in U3O8 CRMs by ICP-AES

    International Nuclear Information System (INIS)

    Liu Husheng

    1994-01-01

    The TBP extractant-containing resin and extraction chromatography technique were used to separate 11 trace elements in U 3 O 8 CRMs. The sample was separated at a flow rate of 0.5 mL/min with 3 mol/L HNO 3 as medium. A model 975 ICP direct reading spectrometer was used to determine the trace elements of Ca, Cd, Cr, Cu, Fe, Mg, Mn, Mo, Ni, Pb and Sn in U 3 O 8 CRMs. The lowest quantitatively determinable concentration of impurities in U 3 O 8 CRMs are 0.02-1.6 μg/g. The RSD is less than 10%. The proposed method provides excellent and accurate analytical data for the U 3 O 8 samples prepared as certified reference materials (CRMs)

  14. Determination of trace elements in ceramic uranium dioxide pellets powders CRMs by ICP-AES

    International Nuclear Information System (INIS)

    Liu Husheng; Li Jun

    1997-01-01

    The 237-quaternary ammonium extraction resin chromatography is used to the separation of 6 trace elements in ceramic uranium dioxide pellets powders, which are used as certified reference materials (CRMs). The sample is dissolved in 6.5 mol/L HNO 3 and uranium is separated by chromatographic column. the 6 trace elements Al, Ba, Co, Ta, Ti and V contained in the elutriant are determined by using ICP directly reading spectrometer. For a 300 mg sample, the lowest determinable concentration of impurities in ceramic UO 2 pellets powders CRMs is (0.016-0.250) x 10 -6 . The relative standard deviation is less than 7.5%. The proposed method provides excellent and accurate analytical data for the ceramic UO 2 pellets powders samples (CRMs)

  15. The determination of some trace elements in sulphide concentrates by spectrophotometry

    International Nuclear Information System (INIS)

    Shelton, B.J.; Komarkova, E.; Josephson, M.; Cook, E.B.T.; Dixon, K.

    1977-01-01

    The report describes the determination of trace amounts (as low as 1 to 10 p.p.m. depending on the element) of arsenic, germanium, molybdenum, nickel, phosphorus, selenium, tellurium, tin, and titanium in sulphide concentrates. The proposed methods, which are detailed in the appendices, are adaptations of established procedures that were modified to allow for the complex nature of the concentrates to be analysed

  16. The determination of an unknown boundary condition in a fractional diffusion equation

    KAUST Repository

    Rundell, William

    2013-07-01

    In this article we consider an inverse boundary problem, in which the unknown boundary function ∂u/∂v = f(u) is to be determined from overposed data in a time-fractional diffusion equation. Based upon the free space fundamental solution, we derive a representation for the solution f as a nonlinear Volterra integral equation of second kind with a weakly singular kernel. Uniqueness and reconstructibility by iteration is an immediate result of a priori assumption on f and applying the fixed point theorem. Numerical examples are presented to illustrate the validity and effectiveness of the proposed method. © 2013 Copyright Taylor and Francis Group, LLC.

  17. Report on the intercomparison for the determination of trace elements in Lake Sediment (SL-1)

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1979-02-01

    The determination of trace element concentrations including those of the rare-earths in geological samples has gained much importance during the past decade. Knowledge of the concentrations of specific elements and of their ratios have proved essential for the understanding of the development of geological strata. With increasing use of instruments in analysis, reference samples have become essential for their calibration and various international organizations have issued reference materials to monitor precision and accuracy in chemical determinations. The IAEA has in the past organized several intercomparisons and prepared reference samples of geochemical materials. The present report deals with a recent intercomparison on the determination of trace elements in Lake Sediment (Sl-1) carried out in 1977-1978 and involving the participation of 43 institutes who returned a total of 2535 individual results on 43 elements.

  18. Optimization of trace elements determination (Arsenic and chromium) in blood and serum of human by electrothermal atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Ahmadi Faghih, M. A.; Aflaki, F.

    2003-01-01

    Trace elements play an important role in the bio physiology of cells by affecting their growth and contributions to various biological processes such as wound healing. Determination of toxic trace elements in biological fluids is an important subject of interest for toxicological purposes. Increasing the concentration of these elements in the blood levels, cause serious diseases in patients. Recently instrumental analysis procedures such as atomic absorption spectrometry have been used in clinical measurements for determination of many toxic trace elements in the biological samples. In this paper we are reporting the study of various methods of blood and serum samples preparation for determining the toxic trace elements of Arsenic and Chromium. The measurement of this elements performed by using electrothermal atomic absorption spectrometry. The best and reliable results for Chromium analysis was achieved by injection of diluted serum samples, where the samples were diluted with H CI 0.1N. In Arsenic analysis, the best results obtained by extraction with aqueous solution of TCA. For determining all of these elements the RSD% was less than 5%

  19. Significant improvement of accuracy and precision in the determination of trace rare earths by fluorescence analysis

    International Nuclear Information System (INIS)

    Ozawa, L.; Hersh, H.N.

    1976-01-01

    Most of the rare earths in yttrium, gadolinium and lanthanum oxides emit characteristic fluorescent line spectra under irradiation with photons, electrons and x rays. The sensitivity and selectivity of the rare earth fluorescences are high enough to determine the trace amounts (0.01 to 100 ppM) of rare earths. The absolute fluorescent intensities of solids, however, are markedly affected by the synthesis procedure, level of contamination and crystal perfection, resulting in poor accuracy and low precision for the method (larger than 50 percent error). Special care in preparation of the samples is required to obtain good accuracy and precision. It is found that the accuracy and precision for the determination of trace (less than 10 ppM) rare earths by fluorescence analysis improved significantly, while still maintaining the sensitivity, when the determination is made by comparing the ratio of the fluorescent intensities of the trace rare earths to that of a deliberately added rare earth as reference. The variation in the absolute fluorescent intensity remains, but is compensated for by measuring the fluorescent line intensity ratio. Consequently, the determination of trace rare earths (with less than 3 percent error) is easily made by a photoluminescence technique in which the rare earths are excited directly by photons. Accuracy is still maintained when the absolute fluorescent intensity is reduced by 50 percent through contamination by Ni, Fe, Mn or Pb (about 100 ppM). Determination accuracy is also improved for fluorescence analysis by electron excitation and x-ray excitation. For some rare earths, however, accuracy by these techniques is reduced because indirect excitation mechanisms are involved. The excitation mechanisms and the interferences between rare earths are also reported

  20. A 'range test' for determining scatterers with unknown physical properties

    Science.gov (United States)

    Potthast, Roland; Sylvester, John; Kusiak, Steven

    2003-06-01

    We describe a new scheme for determining the convex scattering support of an unknown scatterer when the physical properties of the scatterers are not known. The convex scattering support is a subset of the scatterer and provides information about its location and estimates for its shape. For convex polygonal scatterers the scattering support coincides with the scatterer and we obtain full shape reconstructions. The method will be formulated for the reconstruction of the scatterers from the far field pattern for one or a few incident waves. The method is non-iterative in nature and belongs to the type of recently derived generalized sampling schemes such as the 'no response test' of Luke-Potthast. The range test operates by testing whether it is possible to analytically continue a far field to the exterior of any test domain Omegatest. By intersecting the convex hulls of various test domains we can produce a minimal convex set, the convex scattering support of which must be contained in the convex hull of the support of any scatterer which produces that far field. The convex scattering support is calculated by testing the range of special integral operators for a sampling set of test domains. The numerical results can be used as an approximation for the support of the unknown scatterer. We prove convergence and regularity of the scheme and show numerical examples for sound-soft, sound-hard and medium scatterers. We can apply the range test to non-convex scatterers as well. We can conclude that an Omegatest which passes the range test has a non-empty intersection with the infinity-support (the complement of the unbounded component of the complement of the support) of the true scatterer, but cannot find a minimal set which must be contained therein.

  1. Determination of trace elements (Fe, Cu and Zn) in serum and tail ...

    African Journals Online (AJOL)

    Strong and poor relationships between the levels of trace elements in blood, tissue and hair have been determined in various studies. The horses in this study have been fed with dry straw and artificial feed in winter months, with fresh grass in autumn and spring. The purpose was to investigate possible changes in the ...

  2. Determination of trace elements by INAA in urban air particulate matter and transplanted lichens

    International Nuclear Information System (INIS)

    Bergamaschi, L.; Rizzio, E.; Profumo, A.; Gallorini, M.

    2005-01-01

    Lichens as biomonitors and neutron activation analysis as analytical technique have been employed to evaluate the trace element atmospheric pollution in the metropolitan area of the city of Pavia (Northern Italy). Transplanted lichens (Parmelia sulcata and Usnea gr. hirta) and air particulate matter have been monthly collected and analyzed during the winter 2001-2002. INAA and ET-AAS have been used for the determination of 28 elements in air particulate matter and 25 elements in lichens. Trace metals concentrations as well as the corresponding enrichment factors were evaluated and compared. (author)

  3. Determination of trace impurities in high-purity iron using salting-out of polyoxyethylene-type surfactants

    Energy Technology Data Exchange (ETDEWEB)

    Matsumiya, Hiroaki, E-mail: h-matsu@numse.nagoya-u.ac.jp [Department of Molecular Design and Engineering, Graduate School of Engineering, Nagoya University, Furo-cho, Chikusa-ku, Nagoya 464-8603 (Japan); Sakane, Yuto; Hiraide, Masataka [Department of Molecular Design and Engineering, Graduate School of Engineering, Nagoya University, Furo-cho, Chikusa-ku, Nagoya 464-8603 (Japan)

    2009-10-19

    To an iron sample solution was added polyoxyethylene-4-isononylphenoxy ether (PONPE, nonionic surfactant, average number of ethylene oxides 7.5) and the surfactant was aggregated by the addition of lithium chloride. The iron(III) matrix was collected into the condensed surfactant phase in >99.9% yields, leaving trace metals [e.g., Ti(IV), Cr(III), Mn(II), Co(II), Ni(II), Cu(II), Zn(II), Cd(II), Pb(II), and Bi(III)] in the aqueous phase. After removing the surfactant phase by centrifugation, the remaining trace metals were concentrated onto an iminodiacetic acid-type chelating resin. The trace metals were desorbed with dilute nitric acid for the determination by inductively coupled plasma-mass spectrometry or graphite-furnace atomic absorption spectrometry. The proposed separation method allowed the analysis of high-purity iron metals for trace impurities at low {mu}g g{sup -1} to ng g{sup -1} levels.

  4. Using Conductivity Measurements to Determine the Identities and Concentrations of Unknown Acids: An Inquiry Laboratory Experiment

    Science.gov (United States)

    Smith, K. Christopher; Garza, Ariana

    2015-01-01

    This paper describes a student designed experiment using titrations involving conductivity measurements to identify unknown acids as being either HCl or H[subscript 2]SO[subscript 4], and to determine the concentrations of the acids, thereby improving the utility of standard acid-base titrations. Using an inquiry context, students gain experience…

  5. Determination of trace elements in chewing gum by neutron activation analysis

    International Nuclear Information System (INIS)

    Dietz, M.L.

    1990-01-01

    Six trace elements of nutritional or toxicological interest (Al, Ca, Cl, Mn, Na and Sr) were determined in three different brands of chewing gum by instrumental neutron activation analysis. For the particular brands of gum examined, none of the detected elements was found to be present at a level representing a substantial contribution to the total dietary intake of the element for an American adult. (author) 11 refs.; 3 tabs

  6. Determination of trace elements in BCR single cell protein via destructive neutron activation analyses

    International Nuclear Information System (INIS)

    Tjioe, P.S.; Goeij, J.J.M. de; Nooijen, J.L.; Kroon, J.J.

    1978-10-01

    The amount of some trace elements in single cell protein (SCP), a product of BP Research Centre at Sunbury-at-Thames, England, was determined by neutron activation analysis. The SCP-samples were irradiated in the reactor of the Interuniversity Reactor Institute at Delft in a neutron flux of 1.0x10 13 n/cm 2 s for 12 hours. Samples of Bowen's Kale were used as reference material. After a decay of two or three days the samples were chemically destroyed, and the trace elements were separated. The quantity of the following elements was determined by measuring the γ-activity by means of a scintillation counter: antimony, cadmium, mercury, arsenic and selenium. The amounts of these elements in the SCP and in the reference material were tabled

  7. Trace metal determinations by total-reflection x-ray fluorescence analysis in the open Atlantic Ocean

    International Nuclear Information System (INIS)

    Schmidt, D.; Gerwinski, W.; Radke, I.

    1993-01-01

    The Intergovernmental Oceanographic Commission (IOC), as a major component of its programme ''Global Investigation of Pollution in the Marine Environment'' (GIPME), maintains a long-standing project on ''Open Ocean Baseline Studies of Trace Contaminants''. Initially, the Atlantic Ocean and trace metals were selected. Four deep-water stations in the Cape Basin, Angola Basin, Cape Verde Abyssal Plain and Seine Abyssal Plain were regularly sampled for at least 36 depths. Additional samples were taken between stations. Samples were distributed to participants and a similar number of additional laboratories. As a central part of our own contribution to the project, we determined the trace heavy metals manganese, nickel, copper, zinc and lead and the lighter selenium by total-reflection X-ray fluorescence analysis. For the TXRF, the pre-enrichment of the trace metals and the separation from the salt matrix were performed by complexation with sodium dibenzyldithiocarbamate and reverse-phase chromatography. Generally, very low levels of trace elements were found in filtered and unfiltered water samples from these remote areas of the open Atlantic Ocean. Typical examples of the distributions of trace metal concentrations on depth profiles from the four deep-water stations as well as intercomparisons between the stations are presented. (author)

  8. Integration of Solid-phase Extraction with Electrothermal Atomic Absorption Spectrometry for Determination of Trace Elements

    OpenAIRE

    NUKATSUKA, Isoshi; OHZEKI, Kunio

    2006-01-01

    An enrichment step in a sample treatment is essential for trace analysis to improve the sensitivity and to eliminate the matrix of the sample. Solid-phase extraction (SPE) is one of the widely used enrichment technique. Electrothermal atomic absorption spectrometry (ETAAS) is a well-established determination technique for trace elements. The integration of SPE with ETAAS leads to further improvement of sensitivity, an automation of the measurement and the economy in the sample size, amounts o...

  9. Semi-quantitative spectrographic determination of traces of elements in igneous rocks

    International Nuclear Information System (INIS)

    Costa, M.Q. da; Eichhoff, H.-J.

    1982-01-01

    A semi-quantitative spectrographic technique based on Harveys'method, using background radiation as internal standard is described for the analysis of trace elements in igneous rocks by the total energy method. A certain amount of the sample was completely vapourized in a DC arc with anodic excitation under argon and oxygen atmosphere, using graphite electrodes of standard dimensions. In the processed film, selected lines and adjancent backgrounds were evaluated by densitometry and the corresponding intensity ratios were calculated. Sensitivity factors were determined for the analytical lines of Co, Cu, Ga, Ni, Sc, Sr, V, Y, Zn, and Zr in geological standards (G-2, BCR-1, AGV-1, GSP-1) from the United States Geological Survey. Matrix effects between samples and standards were minimized by using the above mentioned geological standards. An average value of the sensitivity factors was employed for the calculation of the concentration of the elements in the samples. A comparison between the results obtained by this method and those from the analysis of zinc by atomic absorption is presented. This method enabled the analyses of igneous rock samples having SiO2 contents between 40 and 80%, with an error in the determinations of trace elements less than 30%.(Author) [pt

  10. X-ray fluorescence analysis for trace element determination in foodstuff chemistry

    International Nuclear Information System (INIS)

    Wildanger, W.

    The physical fundamentals of X-ray fluorescence analysis are given and the routine spectrometers described. The basic principles are given of analytical methods used in qualitative and quantitative fluorescence analyses. Examples are given of the use of the method in a number of fields and the possibility and usefulness is discussed for the determination of trace elements in foodstuffs. The preparation of samples, preliminary concentration of components and calibration methods are discussed. (M.K.)

  11. Trace elements in the diets of Turkish children determined by INAA

    International Nuclear Information System (INIS)

    Aras, N.K.; Mauerhofer, E.; Naidu, R.K.; Arcasoy, A.; Denschlag, H.O.

    1992-01-01

    The role of toxic and essential trace elements in human diet is increasingly important because of environmental problems and the increasingly sophisticated industrial treatment of food products. Instrumental neutron activation analysis (INAA) is particularly well suited for multielement determinations. In order to test and demonstrated the usefulness of the method in connection with the fast pneumatic tube system of the Mainz TRIGA reactor, the authors have analyzed six diet samples of Turkish children

  12. Spectrographic determination of trace impurities in reactor grade aluminium

    International Nuclear Information System (INIS)

    Chandola, L.C.; Machado, I.J.

    1975-01-01

    A spectrographic method enabling the determination of 21 trace impurities in aluminium oxide is described. The technique involves mixing the sample with graphite buffer in the ratio 1:1, loading it in a graphite electrode and arcing it for 30 sec. in a dc arc to 10 A current against a pointed graphite cathode. The spectra are photographed on Ilford N.30 emulsion employing a large quartz spectrograph. The aluminium line at 2669.2 A 0 serves as the internal standard. The impurities determined are Ag, B, Bi, Cd, Co, Cr, Cu, Fe, Ga, In, Mg, Mo, Ni, Pb, Sb, Si, Sn, Ti, V and Zn. The sensitivity varies from 5 to 100 ppm and the precision from +- 5 to +- 22% for different elements. A method for converting aluminium metal to aluminium oxide is described. It is found that boron is not lost during this conversion. (author)

  13. Determination of trace elements in plant samples using XRF, PIXE and ICP-OES techniques

    International Nuclear Information System (INIS)

    Ahmed, Hassan Elzain Hassan

    2014-07-01

    The purpose of this study is to determine trace element concentration (Ca, Cu, Cr, K,Fe, Mn,Sr, and Za) in some sudanese wild plants namely, Ziziphus Abyssinica and Grewia Tenax. X-ray fluorescence ( X RF), particle-induced x-ray emission ( PIXE) and inductively coupled plasma-optical emission spectroscopy (ICP-OES) techniques were used for element determination. A series of plants standard references materials were used to check the reliability of the different employed techniques as well as to estimate possible factors for correcting the concentration of some elements that deviated significantly from their actual concentration. The results showed that, X RF, PIXE and ICP-OES are equally competitive methods for measuring Ca,K, Fe, Sr and Zn elements. Unlikely to ICP-OES seems to be superior techniques tend to be appropriate methods for Cu determination in plant samples however, for Mn element PIXE and ICP-OES are advisable techniques for measuring this element rather than X RF method. On the other hand, ICP-OES seems to be the superior techniques over PIXE and X RF methods for Cr and Ni determination in plant samples. The effect of geographical location on trace elements concentration in plants has been examined through determination of element in different species of Grewia Tenax than collected from different location. Most of measured elements showed similarity indicating there is no significant impact of locations on the difference of element contents. In addition, two plants with different genetic families namely, Ziziphus Spina Christi and Ziziphus Abyssinica were collected from the same location and screened for their trace element content. It was found that there were no difference between the two plants for Ca, K, Cu, Fe, and Sr element. However, significant variations were observed for Mn and Zn concentrations implying the possibility of using of those two elements for plant taxonomy purposes.(Author)

  14. Trace metal contaminants in sediments and soils: comparison between ICP and XRF quantitative determination

    Directory of Open Access Journals (Sweden)

    Congiu A.

    2013-04-01

    Full Text Available A mineralization method HCl-free for heavy metals analysis in sediments and soils by DRC-ICP-MS was developed. The procedure, which uses concentrated nitric, hydrofluoric acid and hydrogen peroxide, was applied for the analysis of arsenic, cadmium, chromium, nickel and vanadium. The same samples were then analyzed, as pressed pellets, by wavelength dispersive X ray fluorescence (WD-XRF using the dedicated PANalytical Pro Trace solution for the determination of trace elements. Comparison of ICP and XRF data showed good agreement for the elements under investigation, unless for chromium in soils, which recovery was not complete.

  15. Studies of effects on determination of trace hydrogen in U-Nb alloy

    International Nuclear Information System (INIS)

    Zou Lexi; Li Yingqiu; Liu Jun; Wu Lunqiang; Qi Lianzhu; Bian Min

    2002-01-01

    The affecting factors for determination of trace hydrogen in U-Nb alloy are studied. The status of samples affects greatly the measured hydrogen content, which has the higher value for scrap sample than cylinder sample. The hydrogen content in cylinder is closer to real value in U-Nb alloy. The hydrogen in U-Nb alloy is mainly from surface adsorption. The results of hydrogen determined by vacuum thermal evolved method, in which the relative standard uncertainty is less than 28%, are in agreement with those by inert-gas fusion method

  16. Extraction inductively coupled plasma-optical emission spectrometry (ICP-OES). Determination of traces of phosphorus in tungsten

    International Nuclear Information System (INIS)

    Bauer, G.; Wegscheider, W.; Mueller, K.

    1989-01-01

    A method for the separation and preconcentration of traces of phosphorus from tungsten was developed. Solid phase extraction of the phosphovanadomolybdate complex performed on a micro-column was applied. Phosphorus was determined by optical emission spectroscopy (OES) with inductively coupled plasma (ICP) excitation. A limit of detection of 0,4 μg/g P with respect to the solid phase is obtained. By directly coupling the extraction/elution step to the ICP instrument a detection limit of 0,06 μg/g P in W was achieved. Besides, the complexity of spectral evaluation in ICP-OES determinations of traces in spectralline-rich matrices is discussed. (Authors)

  17. The use of nuclear related analytical techniques for the determination of ingestion and body content of trace elements

    International Nuclear Information System (INIS)

    Djojosubroto, H.; Santoso, D.; Widjajakusuma, B.

    1998-01-01

    A number of observations revealed that various human disease states are associated with measurable abnormalities of trace element levels. Until present there is no data on trace element levels in human tissues and dietary intake representing the population in Indonesia. Trace element level in various biological materials, especially human serum related to health syndrome (e.g. acute myocardial infarction and goiter prevalences) was performed by National Atomic Energy Agency in cooperation with relevant institutes. The present study is concerned with determination of ingestion and organ content of trace elements of importance in radiological protection (Cs, Sr, I, Th and U). Quantitation of the elements in the samples will be determined by neutron activation analysis, complemented by nuclear related analytical techniques, e.g. inductively coupled plasma - mass spectrometry and atomic absorption spectrometry. Samples to be analyzed consist of (a) total diets and individual staple foodstuffs, (b) autopsy specimens of liver, lung, kidney, muscle, thyroid and bone, and (c) drinking water. It seems difficult for us to define nationally representative specimens of total diets and individual staple foodstuffs. Based on these facts, in the first year activity samples of dietary intake from various socio economic levels of population in West Java will be collected. Human tissue sample is obtained from autopsy of normal persons who are killed in traffic accident or homicide victim. Traces of Th and U in drinking water are determined by neutron activation analysis following preconcentration of these elements in chelating resin Chlelex 100. (author)

  18. Determination of trace elements in Ethiopian, Vietnamese, and Japanese women using high-resolution IC-PMS.

    Science.gov (United States)

    Tekeste, Zinaye; Amare, Bemnet; Asfaw, Fanaye; Fantahun, Bereket; van Nguyen, Nhien; Nishikawa, Takeshi; Yabutani, Tomoki; Okayasu, Takako; Ota, Fusao; Kassu, Afework

    2015-10-01

    Humans and other living organisms require small quantities of trace elements throughout life. Both insufficient and excessive intakes of trace elements can have negative consequences. However, there is little information on serum level of trace elements in different populations. This study examines serum levels of trace elements in Ethiopian, Japanese, and Vietnamese women. Random samples of healthy women who were referred for routine hospital laboratory examinations in the cities of Hanoi, Sapporo, and Gondar were invited to participate in the study. Serum levels of magnesium, zinc, copper, iron, selenium, and calcium were determined using an inductively coupled plasma mass spectrometer. Furthermore, body mass index of each study participant was determined. The mean ± SD serum concentrations of zinc (μg/dL), copper (μg/dL), iron (μg/dL), selenium (μg/dL) and calcium (mg/dL), respectively, were 76.51 ± 39.16, 152.20 ± 55.37, 385.68 ± 217.95, 9.15 ± 4.21, and 14.18 ± 3.91 in Ethiopian women; 111.49 ± 52.92, 105.86 ± 26.02, 155.09 ± 94.83, 14.11 ± 3.41, and 11.66 ± 2.51 in Vietnamese women; and 60.69 ± 9.76, 107 ± 156, 268 ± 128, 8.33 ± 3.65, and 11.18 ± 0.68 in Japanese participants. Ethiopian women had significantly higher level of serum calcium than Vietnamese and Japanese women (both P Vietnamese women was higher than in women from Japan, the difference was not statistically significant (P > 0.05). Furthermore, compared with Japanese women, Ethiopian women had significantly high iron and copper concentrations (P Vietnamese than Ethiopian women. The study revealed a remarkable difference in serum concentrations of trace elements in women from different countries, implying differences in trace elements in the food or soil. Copyright © 2015 Elsevier Inc. All rights reserved.

  19. Abstracts book of 4. Poznan Analytical Seminar on Modern Methods of Sample Preparation and Trace Amounts Determination of Elements

    International Nuclear Information System (INIS)

    1995-01-01

    The 4. Poznan Analytical Seminar on Modern Methods of Sample Preparation and Trace Amounts Determination of Elements has been held in Poznan 27-28 April 1995. The new versions of analytical methods have been presented for quantitative determination of trace elements in biological, environmental and geological materials. Also the number of special techniques for sample preparation enables achievement the best precision of analytical results have been shown and discussed

  20. Use of X-Ray Fluorescence Spectrometry to Determine Trace ...

    African Journals Online (AJOL)

    This paper deals with application of X-ray fluorescence spectrometry for the detection of trace elements in graphic. An X-ray spectrometer was constructed and used to carry out measurements on graphite spheres impregnated with different chemical elements. The intensities of the lines of these trace elements, as function of ...

  1. Luminescent determination of trace amounts of terbium using diantipyrylmethane and salicylic acid

    Energy Technology Data Exchange (ETDEWEB)

    Tishchenko, M A; Gerasimenko, G I; Poluehktov, N S [AN Ukrainskoj SSR, Odessa. Inst. Obshchej i Neorganicheskoj Khimii

    1978-01-01

    To elucidate the possibility of using pyrazolone-5-diantipyril-methane (DAM) derivative for determination of terbium microimpurities, the conditions have been studied of luminescent determination of terbium in complex compounds containing an ion of rare-earth element, diantipyrilmethane, and salicylic acid (Sal.). The ratio between the components in the complex REE-DAM-Sal is 1:1:3. La, Y, Gd do not affect the luminescence intensity of terbium complex. A luminescent method of determining terbium traces in highly pure oxides of lanthanum, gadolinium, lutetium, and yttrium has been developed in which suspensions of complex precipitation are used. The amount of terbium determined in oxide of lanthanum, gadolinium, and lutetium is (1-5)x10/sup -6/% and (2-3)x10/sup -5/% in yttrium oxide.

  2. Determination of trace lithium in uranium compounds by adsorption on activated alumina using a micro-column method.

    Science.gov (United States)

    Luo, Ming-Biao; Li, Bo-Ping; Yang, Zhi; Liu, Wei; Sun, Yu-Zhen

    2008-08-01

    A novel method using a micro-column packed with active alumina as solid phase was proposed for separation of trace lithium from uranium compounds prior to determination. The method is based on a preliminary chromatographic separation of the total amount of uranium. This separation involves passing the solution containing sodium carbonate through active alumina and then eluting the trace lithium retained by the solid phase with a solution of sulfuric acid. Two modes, off-line and on-line micro-column preconcentration, were performed. In conjunction with atomic absorption spectrometry, this on-line preconcentration technique allows a determination of lithium at 10(-9) level. Both off-line and on-line mode operation conditions were investigated in separation and determination of trace lithium by micro-column method (length of column bed, flow rate, etc.). The adsorption capacity of activated alumina was found to be 343 microg g(-1) for lithium. Under the optimal operation condition, the detection limit (DL) of on-line preconcentration corresponding to three times the standard deviation of the blank (S/N = 3) was found to be 1.3 ng mL(-1) and the RSD of this method is 3.32% (n = 5). The on-line calibration graph was linear over the range 20 - 200 ng mL(-1). A good preconcentration factor 820 was achieved by experiment under the on-line mode. The developed method was applied to the analysis of trace lithium in nuclear grade uranium compounds.

  3. Methodology for determination of trace elements in mineral phases of iron banded formation by LA-ICP-MS

    International Nuclear Information System (INIS)

    Sousa, Denise V.M. de; Nalini Junior, Herminio A.; Sampaio, Geraldo M.S.; Abreu, Adriana T. de; Lana, Cristiano de C.

    2015-01-01

    The study of the chemical composition of mineral phases of iron formation (FF), especially of trace elements, is an important tool in the understanding of the genesis of these rocks and the contribution of the phases in the composition of whole rock. Low mass fraction of such elements in the mineral phases present in this rock type requires a suitable analytical procedure. The laser ablation technique coupled with ICP-MS (LA-ICP-MS) has been widely used for determination of trace elements in geological samples. Thus, the aim of this study is to develop calibration curves for determination of trace elements (Y, La, Ce, Pr, Nd, Sm, Eu, Gd, Tb, Dy, Ho, Er, Tm, Yb and Lu) in mineral phases of banded iron formations by LA-ICP-MS. Several certified reference materials (CRM) were used for calibrate the equipment. The analytical conditions were checked by CRM NIST SRM 614. The results were satisfactory, since the curves showed good linearity coefficients, good accuracy and precision of results. (author)

  4. Report on intercomparison A-13 of the determination of trace elements in freeze dried animal blood

    International Nuclear Information System (INIS)

    Pszonicki, L.; Hanna, A.N.; Suschny, O.

    1983-03-01

    This document deals with the comparative evaluation of the analytical data on the trace elements in beef blood obtained by 38 laboratories in 23 countries. The evaluations were based on 799 laboratory mean values of concentration of 41 elements. It was one of the series of IAEA intercomparisons on the determination of trace elements in animal materials. It was organized for the purpose of assisting the participating laboratories to check the accuracy of their work and to prepare a new reference material

  5. Determination of trace elements concentrations in Grewia tenax plants collected from Darfur Region-Sudan

    International Nuclear Information System (INIS)

    Alzain, H. A; Ebrahim, A. M; Salih, A. M; Ali Altom, M. S.

    2016-01-01

    This study is aimed to determine trace elements concentrations (Ca, Cu, Cr, K,Fe, Mn, Ni, Sr and Zn) in Grewia tenax collected from Darfur state western of Sudan. X- ray fluorescence (X RF) technique was used to determine elements concentration. A series of plant standard reference materials(ISE 2012-1) were used to check the reliability of employed technique by comparing the obtained results with the certified values, to estimate possible factors for correcting the concentration of some elements. The results showed that, X RF is a suitable method for measuring Ca, Cu, K, Fe, Mn, Sr and Zn elements. On the other hand, X RF for Cr and Ni determination in plant samples, these elements have showed a deviation from their certified values. Concentration of Fe was about 35 mg/kg in Grewia tenax samples where as K and Ca showed maximum levels about 16000 and 8500 mg/kg respectively, Cu showed minimum concentration about 10 mg/kg. The effect of geographical location on trace elements concentration in plants has been examined through determination of element in different species of Grewia tenax that collected from different locations in Darfur region. Most of the measured elements showed that there is no significant impact of locations on the difference of element contents.(Author)

  6. Determination of trace elements in tea by wavelength dispersive X-ray fluorescence spectroscopy

    International Nuclear Information System (INIS)

    Gong Chunhui; Zeng Guoqiang; Ge Liangquan; Li Jun; Wen Ziqiang

    2013-01-01

    Background: Measuring trace elements in tea can determine its nutritional value, verify the authenticity and place of origin, and detect the poisonous and harmful elements remaining in tea due to the application of chemical fertilizers and pesticides. Purpose: In order to reduce the time for sample preparation and the costs of equipment maintenance, wavelength dispersive X-ray fluorescence (WDXRF) spectroscopy was used to determine the trace elements in tea which is rapid, non-destructive and accurate. The contents of more than 20 elements can be measured simultaneously. Methods: Sample pieces were made by the sample preparation method of boric acid rebasing. To avoid the exogenous environmental pollution subjected in the growth of tea, we removed the residual dust of the tea by cleaning it. According to the principle that the standard samples should be similar types with the samples to be analyzed to select standard samples. The curves were built by SuperQ, which contained compiling the measurement conditions, establishing the measurement conditions, checking the angles, determining the measurement times, checking PHD and adding the contents and the names of sample pieces. The accuracy of the method can be obtained by comparing the measured values with the trace element contents of standard samples. The contents of trace elements in tea determined by WDXRF can be used to classify the tea attribution and the tea species through cluster analysis of SPSS software. Results: (1) The results show that the biggest relative standard deviation is 0.43% of Pb, and the precision is very good. (2) Five kinds of tea are taken separately in Fujian and Yunnan, measured three times with the established working curves. And tree diagram of cluster analysis can be obtained with SPSS software to analyze the measured average values with cluster analysis, coupling method between groups and Minkowski distance measurement techniques. It can be seen that in the tree diagram, when the

  7. Trace element determination using static high-sensitivity inductively coupled plasma optical emission spectrometry (SHIP-OES).

    Science.gov (United States)

    Engelhard, Carsten; Scheffer, Andy; Nowak, Sascha; Vielhaber, Torsten; Buscher, Wolfgang

    2007-02-05

    A low-flow air-cooled inductively coupled plasma (ICP) design for optical emission spectrometry (OES) with axial plasma viewing is described and an evaluation of its analytical capabilities in trace element determinations is presented. Main advantage is a total argon consumption of 0.6 L min(-1) in contrast to 15 L min(-1) using conventional ICP sources. The torch was evaluated in trace element determinations and studied in direct comparison with a conventional torch under the same conditions with the same OES system, ultrasonic nebulization (USN) and single-element optimization. A variety of parameters (x-y-position of the torch, rf power, external air cooling, gas flow rates and USN operation parameters) was optimized to achieve limits of detection (LOD) which are competitive to those of a conventional plasma source. Ionic to atomic line intensity ratios for magnesium were studied at different radio frequency (rf) power conditions and different sample carrier gas flows to characterize the robustness of the excitation source. A linear dynamic range of three to five orders of magnitude was determined under compromise conditions in multi-element mode. The accuracy of the system was investigated by the determination of Co, Cr, Mn, Zn in two certified reference materials (CRM): CRM 075c (Copper with added impurities), and CRM 281 (Trace elements in rye grass). With standard addition values of 2.44+/-0.04 and 3.19+/-0.21 microg g(-1) for Co and Mn in the CRM 075c and 2.32+/-0.09, 81.8+/-0.4, 32.2+/-3.9 for Cr, Mn and Zn, respectively, were determined in the samples and found to be in good agreement with the reported values; recovery rates in the 98-108% range were obtained. No influence on the analysis by the matrix load in the sample was observed.

  8. Determination of trace elements by neutron activation analysis using dinonylnaphtalene sulfonic acid as a preconcentrating agent

    International Nuclear Information System (INIS)

    Yang, M.H.; Chen, P.Y.; Tseng, C.L.; Yeh, S.J.; Weng, P.S.

    1977-01-01

    Dinonylnaphthalene sulfonic acid (HD) has been used as a preconcentrating agent to enrich trace metal ions and to separate the interfering elements such as Na, K, Cl and Br, which normally exist in the natural aqueous systems. Experiments were performed by extracting the ions in the aqueous medium with HD in n-hexane and subsequently backextracted into a minimal volume of acid solution. Factors influencing the extraction efficiency of the ions of interest were investigated. The preconcentration technique has been successfully applied to the determination by neutron activation analysis of trace elements in natural water and biological materials. Both short-lived nuclides (Mg, Al, Ca, Mn) and long-lived nuclides (Sm, Eu, Zn, La, Cr, Sc, Fe, Co) in the ppb-level concentrations were determined. (T.G.)

  9. New trace element determinations in the fingernails of ALS patients

    Energy Technology Data Exchange (ETDEWEB)

    Van Dalsem, D.J.; Ehmann, W.D. [Univ. of Kentucky, Lexington, KY (United States); Robinson, L. [Oak Ridge National Laboratory, TN (United States)

    1996-12-31

    Amyotrophic lateral sclerosis (ALS) afflicts 2 of every 100,000 people in the United States each year. A well-known example of ALS today is Stephen Hawking. He is a theoretical physicist, the author of A Brief History of Time, and is virtually immobilized by ALS. Diseases that cause progressive paralysis because of motor neuron degeneration in the central nervous system are termed motor neuron disorders (MND). Amyotrophic lateral sclerosis is a common form of MND. Pain-free, progressive muscular weakness is the most common clinical symptom. There is chronic weakness with atrophy of the affected muscles by the time the disease is diagnosed. Atrophy eventually results in wheelchair confinement and then only bed without the ability to speak or swallow. Death often occurs as a result of respiratory problems. Unlike other neurodegenerative diseases, in ALS the patient`s bladder and bowel control, eye movement, and mental faculties are preserved. The question today is whether or not certain trace elements are involved in the etiology or pathogenesis of ALS. A collaborative study was undertaken by the University of Kentucky and Oak Ridge National Laboratory (ORNL) using neutron activation analysis (NAA) to study trace element concentrations in ALS patients fingernails to determine if there existed statistically significant imbalances.

  10. Determination of trace element impurities in aspirin tablets by neutron activation analysis

    International Nuclear Information System (INIS)

    Iskander, F.Y.; Klein, D.E.; Bauer, T.L.

    1986-01-01

    Twenty-five trace and minor elements in five different Egyptian aspirin brands (Aspo, Askin, Aspocid, Aspeol and Rivo) were determined by instrumental neutron activation analysis. It was concluded that the concentration of As, Ba, Br, Co, Cr, Fe (except in Aspocid), Mg, Mn, Rb, Se, Sr and Zn in the Egyptian brands is below or within the concentration range reported for these elements in 16 American aspirin and aspirin-like brands. (author)

  11. Trace Elements in Parenteral Nutrition: Considerations for the Prescribing Clinician.

    Science.gov (United States)

    Jin, Jennifer; Mulesa, Leanne; Carrilero Rouillet, Mariana

    2017-04-28

    Trace elements (TEs) are an essential component of parenteral nutrition (PN). Over the last few decades, there has been increased experience with PN, and with this knowledge more information about the management of trace elements has become available. There is increasing awareness of the effects of deficiencies and toxicities of certain trace elements. Despite this heightened awareness, much is still unknown in terms of trace element monitoring, the accuracy of different assays, and current TE contamination of solutions. The supplementation of TEs is a complex and important part of the PN prescription. Understanding the role of different disease states and the need for reduced or increased doses is essential. Given the heterogeneity of the PN patients, supplementation should be individualized.

  12. Trace elements in natural drugs determined by INAA

    International Nuclear Information System (INIS)

    Chen Kehshaw; Tseng Chialiang; Lin Tehsien

    1993-01-01

    Natural drugs are widely used for diuretic, phlegm elimination and stomach invigoration purposes. Seventy-five of the most common remedies used by Chinese people have been subjected to trace element survey analysis by instrumental neutron activation. Within this large number of different natural products, fourteen trace elements (K, Sc, Cr, Fe, Co, Zn, Br, Rb, Cs, La, Sm, Eu, Au and Th) are commonly detected. Among these elements, Fe had the highest concentration followed by Zn, and Rb, Sm, Eu and Au were found to have the lowest concentrations. Although the three groups of natural drugs exhibit a widely different therapeutic action, the concentration ranges of the fourteen elements were very similar. While this suggests no apparent specific role for the trace elements in the drug function, parallels are drawn between the known drug related functions of Rb, Zn, Br, Fe, Co and K and the levels of elements found in the natural drugs. It is concluded that the various natural drugs also provide human benefits through supplements of essential elements such as Fe, Zn, Cr, Sc, Rb and Co. (author) 13 refs.; 5 tabs

  13. Determination of trace amounts of impurities in molybdenum by spark source and glow discharge mass spectrometry

    International Nuclear Information System (INIS)

    Saito, Morimasa

    1994-01-01

    For the determination of trace and ultra-trace amounts of impurities in high-purity molybdenum, spark source mass spectrometry and glow discharge mass spectrometry were studied. In spark source mass spectrometry using the metal probe method, the liquid-helium cryogenic pump was used in order to protect the surface of the samples from oxidation. The theoretical relative sensitivity factors (Mo=1) calculated from physical properties were used. The analytical results obtained for molybdenum tablet and high-purity molybdenum were in good agreement with those obtained by other methods (atomic absorption spectrometry and others). In glow discharge mass spectrometry, the relative sensitivity factors were calculated by using the results obtained by spark source mass spectrometry and atomic absorption spectrometry, and this method was applied to the determination of ultra-trace amounts of impurities in ultra high-purity molybdenum and gave the satisfactory results. The detection limits (2σ, n=10) in the integration time of 600 s for U and Th were 0.6 ppb and 0.3 ppb, and the values for Al, Si, Cr, Mn and Cu were in the range of 10 ppb to 0.5 ppb. (author)

  14. Determination of trace and ultra-trace elements in Dergaon meteorite by inductively coupled plasma mass spectrometry

    International Nuclear Information System (INIS)

    Balaram, V.; Gnaneswara Rao, T.; Anjaiah, K.V.; Phukon, N.; Majumdar, A.C.

    2003-01-01

    In this paper, a detailed methodology for high precision measurement of several trace and ultra-trace elements including REE and PGE have been presented using effective sample preparation techniques and inductively coupled plasma mass spectrometry. Discussion is focussed on aspects, such as total dissolution and recovery of all elements, minimization of oxide and doubly-charged and other polyatomic ion interferences, calibration by matrix matching standards, accuracy and precision

  15. Determination of short-lived trace elements in environmental samples by neutron activation analysis

    International Nuclear Information System (INIS)

    Wardani, S.; Sihombing, E.; Hamzah, A.; Rochidi; Hery, P.S.; Hartaman, S.; Iman, J.

    1998-01-01

    Concentration of a short-lived trace elements in environmental samples were determined by neutron activation analysis, a counting loss often occur due to the high counting rate. A Pile-Up Rejecter (PUR) electric circuit was installed in counting a short-lived trace elements by a γ-ray spectrometer in order to correct a counting loss. The samples were irradiated for 30∼60 seconds at neutron flux of 3.5 x 10 12 n.cm -2 .s -1 , then the samples cooled for 120 second and counted for 180 second using this system. The nuclides concentration in the varieties environmental samples have a difference analysis result, was more accurate and precise, which the measured result would be 30 % more higher by PUR system than the result would be counted using a conventional γ-ray spectrometry method

  16. use of x-ray fluorescence spectrometry to determine trace elements ...

    African Journals Online (AJOL)

    NIJOTECH

    Abstract. This paper deals with application of X-ray fluorescence spectrometry for the detection of trace elements in graphic. An X-ray spectrometer was constructed and used to carry out measurements on graphite spheres impregnated with different chemical elements. The intensities of the lines of these trace elements, ...

  17. Determination of trace elements in ground water by two preconcentration methods using atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Elhag, A. Y.

    2004-01-01

    This is a comparative study between two different methods of preconcentration done to separate the trace elements cadmium, nickel. chromium, manganese, copper, zinc, and lead in drinking (ground) water samples taken from different locations in Gezira State, central Sudan (the map); these methods are (coprecipitation) with aluminium hydroxide and by Ammonium Pyrrolidine Dithiocarbamate (APDC) using Methyl Isobutyl Ketone (MIBK) as an organic solvent; and subsequent analysis by Atomic Absorption Spectrometry (AAS) for both methods. The result of comparison showed the superiority of the (APDC) coprecipitation method over the aluminium hydroxide coprecipitation method in the total percentage recoveries of the studied trace elements in drinking (ground) water samples, such results confirm previous studies. This study also involves direct analysis of these water samples by atomic absorption spectrometry to determine the concentrations of trace elements Cadmium, Nickel, Chromium, Manganese, Copper, Zinc and Lead and compare it to the corresponding guide line values described by the World Health Organization and the maximum concentrations of trace elements in drinking water permitted by the Sudanese Standards and Metrology Organizations (SSMO), where the concentrations of some elements in some samples were found to be different than the described values by both of the organizations. The study includes a trial to throw light on the effect of the proximity of the water samples sources to the Blue Nile river on its trace elements concentrations; no relation was proved to exist in that respect.(Author)

  18. Trace element determinations in brain tissues from normal and clinically demented individuals

    International Nuclear Information System (INIS)

    Saiki, Mitiko; Genezini, Frederico A.; Leite, Renata E.P.; Grinberg, Lea T.; Ferretti, Renata E.L.; Suemoto, Claudia; Pasqualucci, Carlos A.; Jacob-Filho, Wilson

    2013-01-01

    Studies on trace element levels in human brains under normal and pathological conditions have indicated a possible correlation between some trace element concentrations and neurodegenerative diseases. In this study, analysis of brain tissues was carried out to investigate if there are any differences in elemental concentrations between brain tissues from a normal population above 50 years of age presenting Clinical Dementia Rating (CDR) equal to zero (CDR=0) and that cognitively affected population ( CDR=3). The tissues were dissected, ground, freeze-dried and then analyzed by instrumental neutron activation analysis. Samples and elemental standards were irradiated in a neutron flux at the IEA-R1 nuclear research reactor for Br, Fe, K, Na, Rb, Se and Zn determinations. The induced gamma ray activities were measured using a hyperpure Ge detector coupled to a gamma ray spectrometer. The one-way ANOVA test (p< 0.05) was used to compare the results. All the elements determined in the hippocampus brain region presented differences between the groups presenting CDR=0 and CDR=3. In the case of frontal region only the elements Na, Rb and Zn showed differences between these two groups. These findings proved the correlation between elemental levels present in brain tissues neurodegenerative diseases. Biological standard reference materials SRM 1566b Oyster Tissue and SRM 1577b Bovine Liver analyzed for quality control indicated good accuracy and precision of the results. (author)

  19. Determination of artificial and natural radionuclides and others trace elements in environmental samples form Antarctica

    International Nuclear Information System (INIS)

    Schuch, L.A.; Godoy, J.M.; Nordemann, D.J.R.

    1994-01-01

    The results of the radioactive elements concentrations, determined by gamma spectrometry and the others trace elements determined by neutron activation analysis of several environmental samples (soils, marine sediments, algae mosses and lichens) in Comandante Ferraz Antartica Station are presented. The high concentrations of Cs-137 were found in lichens and mosses samples and the soils and sediments showed concentrations of natural radionuclides. (C.G.C.). 8 refs, 1 fig, 3 tabs

  20. The determination of traces of uranium by means of laser fluorometry

    International Nuclear Information System (INIS)

    Venter, R.J.

    1987-11-01

    A method and apparatus were developed to quantitatively determine traces of uranium. A xenon chloride excimer laser was used as an excitation source, which provided various advantages above the conventional light sources. Boxcar integration was used to limit background fluorescence by time-resolved fluorescence spectroscopy. A characteristic wavelength of uranium fluorescence was selected with cut-off filters and a monochromator. The effect of different matrices on the fluorescence of uranium was determined, and the most suitable matrix for quantitative analysis was chosen. A quick and simple method for determining uranium was developed. A combined water sample of industrial effluent was used to evaluate the method. The effect of interfering species, characteristic of the water sample, was examined. A standard addition technique was used to compensate for the effect of the interfering species. The detection limit of uranium in pure water was calculated at three times the standard deviation of the blank sample and was found to be 14 pg/cm 3

  1. Plutonium-236 traces determination in plutonium-238 by α spectrometry

    International Nuclear Information System (INIS)

    Acena, M.L.; Pottier, R.; Berger, R.

    1969-01-01

    Two methods are described in this report for the determination of plutonium-236 traces in plutonium-238 by a spectrometry using semi-conductor detectors. The first method involves a direct comparison of the areas under the peaks of the α spectra of plutonium-236 and plutonium-238. The electrolytic preparation of the sources is carried out after preliminary purification of the plutonium. The second method makes it possible to determine the 236 Pu/ 238 Pu ratio by comparing the areas of the α peaks of uranium-232 and uranium-234, which are the decay products of the two plutonium isotopes respectively. The uranium in the source, also deposited by electrolysis, is separated from a 1 mg amount of plutonium either by a T.L.A. extraction, or by the use of ion-exchange resins. The report ends with a discussion of the results obtained with plutonium of two different origins. (authors) [fr

  2. Determination of trace amounts of cadmium in zirconium and its alloys by graphite furnace AAS

    International Nuclear Information System (INIS)

    Takashima, Kyoichiro; Toida, Yukio

    1994-01-01

    Trace amount of cadmium in zirconium and its alloys was determined by graphite furnace atomic absorption spectrometry (GF-AAS) after ion exchange separation. A 2g chip sample was decomposed with 20ml of hydrofluoric acid (1+9) and a few drops of nitric acid. A trace amount of cadmium was separated from zirconium by strongly acidic cation-exchange resin (MCI GEL CK 08P) using 50ml of hydrochloric acid as an eluent. The solution was gently evaporated to dryness on an electric hot plate heater and under an infrared lamp. The residue was dissolved in 1ml of nitric acid (1+14) and diluted to 10ml in a volumetric glass flask with distilled water. Ten microliters of this solution was injected into a graphite furnace and then atomized at 2200degC for 4s in argon at a flow rate of 3.0l/min. Acids used in the analytical procedure were purified by azeotropic distillation and cation-exchange resin. The limit of determination (3σ BK ) for cadmium was 0.5ngCd/g and the relative standard deviation (RSD) at 1ngCd/g level was less than 20% for the GF-AAS. The accuracy of this technique was confirmed by NIST SRM 1643b (trace elements in water). (author)

  3. Quantitative determination of minor and trace elements in rocks and soils by spark source mass spectrometry

    International Nuclear Information System (INIS)

    Ure, A.M.; Bacon, J.R.

    1978-01-01

    Experimental details are given of the quantitative determination of minor and trace elements in rocks and soils by spark source mass spectrometry. The effects of interfering species, and corrections that can be applied, are discussed. (U.K.)

  4. Optimization of experimental conditions in uranium trace determination using laser time-resolved fluorimetry

    International Nuclear Information System (INIS)

    Baly, L.; Garcia, M.A.

    1996-01-01

    At the present paper a new sample excitation geometry is presented for the uranium trace determination in aqueous solutions by the Time-Resolved Laser-Induced Fluorescence. This new design introduces the laser radiation through the top side of the cell allowing the use of cells with two quartz sides, less expensive than commonly used at this experimental set. Optimization of the excitation conditions, temporal discrimination and spectral selection are presented

  5. Possibilities of High Resolution Inductively Coupled Plasma Optical Emission Spectrometry in the Determination of Trace Elements in Environmental Materials

    Directory of Open Access Journals (Sweden)

    Nikolaya Velitchkova

    2013-01-01

    Full Text Available This paper presents new quantitative data for the spectral interferences obtained by high resolution 40.68 MHz radial viewing inductively coupled plasma optical emission spectrometry (HR-ICP-OES in the determination of Zn, Cd, Sb, Cu, Mn, Pb, Sn, Cr, U, and Ba in environmental materials in the presence of a complex matrix, containing Al, Ca, Fe, Mg, and Ti. The -concept for quantification of spectral interferences was used. The optimum line selection for trace analysis of a variety of multicomponent matrices requires the choice of prominent lines, which are free or negligibly influenced by line interference problems. The versatility of -concept as basic methodology was experimentally demonstrated in the determination of trace of elements in soil and drinking water. The detection limits are lower in comparison with corresponding threshold concentration levels for soil and drinking water in accordance with environmental regulations. This paper shows the possibilities of present day ICP-OES equipment in the direct determination of trace elements (without preconcentration of impurities in environmental samples.

  6. World-wide intercomparison exercise for the determination of trace elements in Fucus sample IAEA-140. Report no. 64

    International Nuclear Information System (INIS)

    Coquery, M.; Carvalho, F.P.; Horvat, M.; Azemard, S.

    1997-09-01

    The accurate and precise determination of trace elements in marine samples is fundamental to pollution assessment in coastal and marine environments. Analyses of sea plants are important to investigate the uptake of toxic elements along the trophic chain and sea plants may be used as indicators for water pollution and to compare the levels of contamination of different aquatic environments. IAEA. together with UNEP and the Intergovernmental Oceanographic Commission (IOC) work closely with other producers of Reference Materials in order to assure a continuous supply of these vital compounds for quality assurance procedures. A full catalogue of materials is published regularly. The Marine Environmental Studies Laboratory (MESL) of IAEA-MEL has conducted intercomparison exercises on trace elements for over twenty years as part of its contribution to IAEA's Analytical Quality Control Service, UNEP's Regional Seas Programme. and, occasionally, in association with the IOC GIPME (Global Investigation of the Pollution in the Marine Environment) programme. This report describes the performance of laboratories in one intercomparison run conducted during 1996 that was organized for the determination of trace elements in a marine macro algae (Fucus sp.) sample. This study was intended to give laboratories responsible for trace element analyses of marine materials an opportunity for checking their analytical performance

  7. Essential trace elements content in a sudanese meal of cooked Hibiscus Sp. leaves as determined by both X-ray florescence and atomic absorption spectroscopy techniques

    International Nuclear Information System (INIS)

    Mohamed, S.M; Taha, M.H.

    2003-01-01

    Essential trace elements content of a Sudanese meal of cooked Karkadi plant leaves (Hibiscus Sp)was determined and found to be several folds higher than the average trace element content of Sudanese food as determined in twenty nine daily consumed mixed diets. Therefore, this plant can act as a promising natural supplement in cases of deficiency provided it is grown in a trace element rich soil. (Author)

  8. Experimental determination of the empirical formula and energy content of unknown organics in waste streams

    Energy Technology Data Exchange (ETDEWEB)

    Shizas, I. [Univ. of Toronto, Dept. of Civil Engineering, Toronto, Ontario (Canada); Kosmatos, A. [Ontario Power Generation, Toronto, Ontario (Canada); Bagley, D.M. [Univ. of Toronto, Dept. of Civil Engineering, Toronto, Ontario (Canada)

    2002-06-15

    Two experimental methods are described in this paper: one for determining the empirical formula, and one for determining the energy content of unknown organics in waste streams. The empirical formula method requires volatile solids (VS), chemical oxygen demand (COD), total organic carbon (TOC), and total Kjeldahl nitrogen (TKN) to be measured for the waste; the formula can then be calculated from these values. To determine the energy content of the organic waste, bomb calorimetry was used with benzoic acid as a combustion aid. The results for standard compounds (glucose, propionic acid, L-arginine, and benzoic acid) were relatively good. The energy content measurement for wastewater and sludges had good reproducibility (i.e. 1.0 to 3.2% relative standard deviation for triplicate samples). Trouble encountered in the measurement of the empirical formulae of the waste samples was possibly due to difficulties with the TOC test; further analysis of this is required. (author)

  9. Experimental determination of the empirical formula and energy content of unknown organics in waste streams

    International Nuclear Information System (INIS)

    Shizas, I.; Kosmatos, A.; Bagley, D.M.

    2002-01-01

    Two experimental methods are described in this paper: one for determining the empirical formula, and one for determining the energy content of unknown organics in waste streams. The empirical formula method requires volatile solids (VS), chemical oxygen demand (COD), total organic carbon (TOC), and total Kjeldahl nitrogen (TKN) to be measured for the waste; the formula can then be calculated from these values. To determine the energy content of the organic waste, bomb calorimetry was used with benzoic acid as a combustion aid. The results for standard compounds (glucose, propionic acid, L-arginine, and benzoic acid) were relatively good. The energy content measurement for wastewater and sludges had good reproducibility (i.e. 1.0 to 3.2% relative standard deviation for triplicate samples). Trouble encountered in the measurement of the empirical formulae of the waste samples was possibly due to difficulties with the TOC test; further analysis of this is required. (author)

  10. Selberg trace formula for bordered Riemann surfaces: Hyperbolic, elliptic and parabolic conjugacy classes, and determinants of Maass-Laplacians

    International Nuclear Information System (INIS)

    Bolte, J.

    1992-08-01

    The Selberg trace formula for automorphic forms of weight m ε- Z, on bordered Riemann surfaces is developed. The trace formula is formulated for arbitrary Fuchsian groups of the first kind which include hyperbolic, elliptic and parabolic conjugacy classes. In the case of compact bordered Riemann surfaces we can explicitly evaluate determinants of Maass-Laplacians for both Dirichlet and Neumann boundary-conditions, respectively. Some implications for the open bosonic string theory are mentioned. (orig.)

  11. Determination of trace elements in coffee beans and instant coffee of various origins by INAA

    International Nuclear Information System (INIS)

    Zaidi, J.H.; Fatima, I.; Arif, M.; Qureshi, I.H.

    2006-01-01

    Extensive use of coffee, by one-third of world's population, entails the evaluation of trace element contents in it. Instrumental neutron activation analysis (INAA) was successfully employed to determine the concentration of 20 trace elements (essential, toxic and nonessential) in four samples of coffee beans of various origins and two instant coffee brands most commonly consumed in Pakistan. Base-line values of certain toxic and essential elements in coffee are provided. The daily intake of essential and toxic elements through coffee was estimated and compared with the recommended values. The cumulative intake of Mn is four times higher than the recommended value and that of toxic elements is well below the tolerance limits. (author)

  12. Determination of phosphorus traces in platinum alloys by two-phase isotope exchange

    International Nuclear Information System (INIS)

    Vlacil, F.

    1980-01-01

    The method of ZEMAN and KRATZER for the determination of phosphorus traces by means of two-phase isotope exchange was modified for the determination of phosphorus in pure platinum or pure platinum alloys. It was found that Pt, Rh, Ag and As do not interfere with the determination. Among the elements usually present in platinum metal or platinum alloys, only gold interferes. It was removed by extraction from 7M HCl by MIBK and AmOAc. Hydrochloric acid also interferes but it can be removed by evaporation. The analytical procedure is given for the solution obtained by pressure decomposition of the sample (0.5 g) in a steel bomb with PTFE inlay. It is possible to determine > 2 ppm P (approximate error -10%). If using calibration dependence instead of the well known equation for isotope exchange it is not necessary to know the content of P in the standard solution labelled with 32 P. (author)

  13. Application of anion-exchange techniques to the determination of traces of molybdenum in sea-water

    International Nuclear Information System (INIS)

    Kiriyama, T.; Kuroda, R.

    1984-01-01

    A combined ion-exchange spectrophotometric method has been developed for the determination of molybdenum in sea-water. Molybdenum is sorbed strongly on Amberlite CG 400 (Cl - ) at pH 3 from sea-water containing ascorbic acid and is easily eluted with 6 M nitric acid. Molybdenum in the effluent can be determined spectrophotometrically with potassium thiocyanate and stannous chloride. The combined method allows selective and sensitive determination of traces of molybdenum in sea-water. The precision of the method is 2% at a molybdenum level of approx. 10 μg/l. (author)

  14. Spectrographic Determination of Trace Constituents in Rare Earths; Determinacion espectrografica de impurezas en tierras raras

    Energy Technology Data Exchange (ETDEWEB)

    Capdevila, C; Alvarez, F

    1962-07-01

    A spectrographic method was developed for the determination of 18 trace elements in lanthanum, cerium, praseodimium, neodimium and samarium compounds. The concentrations of the impurities cover the range of 0,5 to 500 ppm. Most of these impurities are determined by the carrier distillation method. Several more refractory elements have been determined by total burning of the sample with a direct current arc or by the conduction briquet excitation technique with a high voltage condensed spark. The work has been carried out with a Hilger Automatic Large Quartz Spectrograph. (Author) 5 refs.

  15. Determination of trace elements of Egyptian crops by neutron activation analysis Pt. 3

    International Nuclear Information System (INIS)

    Sherif, M.K.; Awadallah, R.M.; Amrallah, A.H.

    1980-01-01

    Multielemental neutron activation analysis was used for the determination of Al, As, Au, Br, Ca, Cd, Co, Cr, Cu, Fe, La, Mn, Mo, Sb, Se, W and Zn in African tea and lady's fingers (Malvaceae Family), ginger (Zingiperanceae Family), canella bark (Laureceae Family), black pepper (Piperaceae Family), cucumber seeds and vegetable marrow seeds (Cucurbitaceae Family), tomatos seed (Solanaceae Family), safflower seeds (Compositae Family), jew's mallow seed (Tiliaceae Family) and sesame (Pedaliaceae Family). Trace elements determination was made for the analysis of destructive (using super pure nitric acid and adsorbing the metal-APDC and metal-Dz complexes on activated charcoal) and nondestructive (dry seeds) samples. The method is simple, precise and sensitive for the determination of microamounts of the elements (ppm to ppb). (author)

  16. Determination of several trace elements in Chinese herbs with epithermal neutral activation analysis

    International Nuclear Information System (INIS)

    Chen, Chien-Yi; Chang Lai, Sheng-Pin

    2002-01-01

    For purpose of medication and health, Chinese herbs have been long adopted throughout oriental communities. Thus, more than ten trace elements in herbal medicines that are frequently consumed by children in central Taiwan were analyzed herein to explore the importance of various herbs. These elements are considered beneficial to human health in many folds. INAA was applied to determine the concentrations of elements as Al, Cl and Sc, while ENAA analyzed As, Cd, Mn, and Sb in this work. Among various local herbs, the elemental concentrations varied from 10 4 to 10 -3 μg/g. The experimental results suggest that the ENAA method can be applied successfully to analyze trace elements of As, Cd, Mn, and Sb in herbs. Yet, thirteen elements were verified, and a quantified index AT was introduced to help classifying the elements. The ATs in various Chinese herbs are also discussed herein and the accuracy is in excellent agreement with values reported in previously published data. (author)

  17. Determination of several trace elements in Chinese herbs with epithermal neutral activation analysis

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Chien-Yi [Chung Shan Medical Univ., Inst. of Biochemistry, Taiwan (China); Chang Lai, Sheng-Pin [Chung Shan Medical Univ. Hospital, Dept. of Nuclear Medicine Chief, Taiwan (China)

    2002-04-01

    For purpose of medication and health, Chinese herbs have been long adopted throughout oriental communities. Thus, more than ten trace elements in herbal medicines that are frequently consumed by children in central Taiwan were analyzed herein to explore the importance of various herbs. These elements are considered beneficial to human health in many folds. INAA was applied to determine the concentrations of elements as Al, Cl and Sc, while ENAA analyzed As, Cd, Mn, and Sb in this work. Among various local herbs, the elemental concentrations varied from 10{sup 4} to 10{sup -3} {mu}g/g. The experimental results suggest that the ENAA method can be applied successfully to analyze trace elements of As, Cd, Mn, and Sb in herbs. Yet, thirteen elements were verified, and a quantified index AT was introduced to help classifying the elements. The ATs in various Chinese herbs are also discussed herein and the accuracy is in excellent agreement with values reported in previously published data. (author)

  18. Determination of trace amounts of tin in geological materials by atomic absorption spectrometry

    Science.gov (United States)

    Welsch, E.P.; Chao, T.T.

    1976-01-01

    An atomic absorption method is described for the determination of traces of tin in rocks, soils, and stream sediments. A dried mixture of the sample and ammonium iodide is heated to volatilize tin tetraiodide -which is then dissolved in 5 % hydrochloric acid, extracted into TOPO-MIBK, and aspirated into a nitrous oxide-acetylene flame. The limit of determination is 2 p.p.m. tin and the relative standard deviation ranges from 2 to 14 %. Up to 20 % iron and 1000 p.p.m. Cu, Pb, Zn, Mn, Hg, Mo, V, or W in the sample do not interfere. As many as 50 samples can be easily analyzed per man-day. ?? 1976.

  19. Informative importance of determination of trace elements in biologocal mediums in patients with endocrine pathology

    Directory of Open Access Journals (Sweden)

    Ирина Николаевна Андрусишина

    2015-07-01

    Full Text Available Aim. The changes of mineral metabolism in human organism caused by the deficiency or excess of trace elements in environment (air, food stuffs, water can lead to disorder of functional status of organism.An excess or deficiency of the certain metals disturb the balance of metabolic processes in organism that causes the different changes in endocrine system too. That is why the aim of research was to detect the peculiarities of distribution of macro and trace elements in patients with different endocrine pathology and to show the reasonability of the complex approach in assessment of microelementoses at hyperthyroidism and diabetes mellitus.Methods. The balance of 15 macro and trace elements in different biological mediums (hairs, whole blood, blood serum, urine was studied using EAAS and AES-ICP methods.Result. There was demonstrated the high informative importance of determination of K, Mg, Mn, Cr, Zn at pancreas pathology and Cr, Mn, Se, Zn- at thyroid pathology in human. There was detected that endocrine pathology is characterized with the surplus accumulation of Al, As and Pb in organism of examined patients.Conclusions. To increase the reliability and efficiency of the clinical diagnostics of endocrine human pathology there was demonstrated the high informative importance of the complex approach in choice of biological mediums at assessment of the trace elements imbalance. 

  20. Trace Elements in the Conductive Tissue of Beef Heart Determined by Neutron Activation Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Wester, P O

    1965-08-15

    By means of neutron activation analysis, samples of four beef hearts taken from the bundle of His and adjacent ventricular muscle, the AV node and adjacent atrial muscle are investigated with respect to the concentration of 23 trace elements. The bulk elements K, Na and P are also determined. A recently developed ion-exchange technique, combined with subsequent {gamma}-spectrometry, is used. The following trace elements are determined: Ag, As, Au, Ba, Br, .Ca, Cd, Ce, Co, Cr, Cs, Cu, Fe, Hg, La, Mo, Rb, Sb, Sc, Se, Sm, W and Zn. In the conductive tissue compared to adjacent muscle tissue, calculations on a wet weight basis show a lower concentration of Cs, Cu, Fe, K, P, Rb and Zn in the former, and a higher concentration of Ag, Au, Br, Ca and Na. The mean differences ({mu}g/g wet tissue), as well as their degree of significance, between the bundle of His and adjacent tissue from the ventricular septum, between the AV node and adjacent atrial muscle, between the ventricular septum and the right atrium, and between the bundle of His and the AV node are given for the elements Cu, Fe, K, Na, P and Zn.

  1. Trace Elements in the Conductive Tissue of Beef Heart Determined by Neutron Activation Analysis

    International Nuclear Information System (INIS)

    Wester, P.O.

    1965-08-01

    By means of neutron activation analysis, samples of four beef hearts taken from the bundle of His and adjacent ventricular muscle, the AV node and adjacent atrial muscle are investigated with respect to the concentration of 23 trace elements. The bulk elements K, Na and P are also determined. A recently developed ion-exchange technique, combined with subsequent γ-spectrometry, is used. The following trace elements are determined: Ag, As, Au, Ba, Br, .Ca, Cd, Ce, Co, Cr, Cs, Cu, Fe, Hg, La, Mo, Rb, Sb, Sc, Se, Sm, W and Zn. In the conductive tissue compared to adjacent muscle tissue, calculations on a wet weight basis show a lower concentration of Cs, Cu, Fe, K, P, Rb and Zn in the former, and a higher concentration of Ag, Au, Br, Ca and Na. The mean differences (μg/g wet tissue), as well as their degree of significance, between the bundle of His and adjacent tissue from the ventricular septum, between the AV node and adjacent atrial muscle, between the ventricular septum and the right atrium, and between the bundle of His and the AV node are given for the elements Cu, Fe, K, Na, P and Zn

  2. Trace element determination in soft tissues of marine bivalves by activation analysis

    International Nuclear Information System (INIS)

    Fukushima, M.; Tamate, H.; Nakano, Y.

    2003-01-01

    Trace elements in soft tissues of marine bivalves were determined by neutron activation analysis (NAA) and photon activation analysis (PAA). Elemental levels of Ag, As, Br, Co, Cu, Fe, I, Mn, Ni, Rb, Se, and Zn in the organs of giant ezoscallos, rock oysters, and giant crams were obtained. The metal-bound proteins were extracted from the mantles and hepatopancreases of rock oysters. By irradiating the fraction obtained by HPLC gel chromatography, the possibility for the existence of an Ag bound protein in the mantles was found. (author)

  3. Determination of trace elements in human brain tissues using neutron activation analysis

    International Nuclear Information System (INIS)

    Leite, R.E.P.; Jacob-Filho, W.; Grinberg, L.T.; Ferretti, R.E.L.

    2008-01-01

    Neutron activation analysis was applied to assess trace element concentrations in brain tissues from normal (n = 21) and demented individuals (n = 21) of both genders aged more than 50 years. Concentrations of the elements Br, Fe, K, Na, Rb, Se and Zn were determined. Comparisons were made between the results obtained for the hippocampus and frontal cortex tissues, as well as, those obtained in brains of normal and demented individuals. Certified reference materials, NIST 1566b Oyster Tissue and NIST 1577b Bovine Liver were analyzed for quality of the analytical results. (author)

  4. Determination of Trace Elements In Soil and Plants In Coastal Basin of Syria By Using Instrumental Neutron Activation Analysis

    International Nuclear Information System (INIS)

    Kassem, A.

    2004-01-01

    Instrumental neutron activation analysis (INAA) methods have been used for the determination of some major, minor and trace elements (As, Cr, Co, Ni, Zn, Sb, Sc Ce, Ti, Fe, Mn and V) in some kinds of plant leaves with their soil. Accuracy of measurements have been evaluated by analyzing a number of plant and soil reference materials, precision have been estimated by triplicate the sample as well as the reference. The obtained accurate and reliable data in microgram quantities of some trace elements in plants and soil will serve as baseline values and will be helpful to monitor the changes in the trace elements content of soil and plant leaves. (Author)

  5. Tracing the origin of glomerular extracapillary lesions from parietal epithelial cells.

    NARCIS (Netherlands)

    Smeets, B.; Uhlig, S.; Fuss, A.; Mooren, F.; Wetzels, J.F.M.; Floege, J.; Moeller, M.J.

    2009-01-01

    Cellular lesions form in Bowman's space in both crescentic glomerulonephritis and collapsing glomerulopathy. The pathomechanism and origin of the proliferating cells in these lesions are unknown. In this study, we examined proliferating cells by lineage tracing of either podocytes or parietal

  6. Offset Trace-Based Video Quality Evaluation Network Transport

    DEFF Research Database (Denmark)

    Seeling, P.; Reisslein, M.; Fitzek, Frank

    2006-01-01

    Video traces contain information about encoded video frames, such as frame sizes and qualities, and provide a convenient method to conduct multimedia networking research. Although wiedely used in networking research, these traces do not allow to determine the video qaulityin an accurate manner...... after networking transport that includes losses and delays. In this work, we provide (i) an overview of frame dependencies that have to be taken into consideration when working with video traces, (ii) an algorithmic approach to combine traditional video traces and offset distortion traces to determine...... the video quality or distortion after lossy network transport, (iii) offset distortion and quality characteristics and (iv) the offset distortion trace format and tools to create offset distortion traces....

  7. The determination of minor isotope abundances in naturally occurring uranium materials. The tracing power of isotopic signatures for uranium

    International Nuclear Information System (INIS)

    Ovaskainen, R.

    1999-01-01

    facilities (Australia, Canada, Gabon, Namibia, Czech Republic, France), were determined. These signatures form the basic register. The isotopic signatures are feasible in identifying the sample origin and in separating naturally occurring or background contributions from local anthropogenic sources. With the comparison of fingerprints of unknown samples to the isotopic fingerprints of samples of known origin, it is possible to trace back unknown samples to their origin or at least to exclude suspected origins in the case of non-identity of fingerprints. This was successfully demonstrated with a number of samples of unknown origin, which were measured during the study. Generally, no significant variability was observed in the n( 235 U)/n( 238 U) ratios except in the well known case of samples originating from Oklo (Gabon). Small variations in the n( 234 U)/n( 238 U) amount ratios were understood from the radiochemical mother-daughter relationship of the two isotopes involved. The detection limit for the n( 236 U)/n( 235 U) amount ratio (DL = 0.000001) was derived from blank measurements. The limit of quantitation 0.000003 was calculated as LQ=3DL. When the measured ratio exceeded the quantitation limit, the presence of 236 U is explained. (orig.)

  8. The determination of trace elements in uranium ores by x-ray fluorescence spectrometry

    International Nuclear Information System (INIS)

    De Villiers, W. van Z.

    1983-11-01

    The determination of 17 trace elements (As, Ba, Co, Cr, Cu, Mo, Nb, Ni, Pb, Rb, Sr, Th, U, V, Y, Zn and Zr) in uranium ores by x-ray fluorescence spectrometry was investigated in this study. The determination of major elements was also necessary for the calculation of mass absorption coefficients. Initially a method was developed for the determination of the elements of interest in unmineralised silicates. Correction for absorption of radiation by the sample were made by means of mass absorption coefficients which were obtained from the relation between the inverse of the mass absorption coefficient and the intensity of the Compton scattering peak. The Feather and Willis method was used for determining the background intensity at the peak positions as well as for mass absorption coefficients. It was observed that the background intensity in the region of the uranium lines increases with increasing uranium content of the sample

  9. Integrated luminometer for the determination of trace metals in seawater using fluorescence, phosphorescence and chemiluminescence detection

    OpenAIRE

    Worsfold, P. J.; Achterberg, E. P.; Bowie, A. R.; Cannizzaro, V.; Charles, S.; Costa, J. M.; Dubois, F.; Pereiro, R.; San Vicente, B.; Sanz-Medel, A.; Vandeloise, R.; Donckt, E. Vander; Wollast, P.; Yunus, S.

    2002-01-01

    The paper describes an integrated luminometer able to perform fluorescence (FL), room temperature phosphorescence (RTP) and chemiluminescence (CL) measurements on seawater samples. The technical details of the instrumentation are presented together with flow injection (FI) manifolds for the determination of cadmium and zinc (by FL), lead (RTP) and cobalt (CL). The analytical figures of merit are given for each mainfold and results are presented for the determination of the four trace metals i...

  10. Determination of trace and toxic elements in marine sediments collected from the strait of Malacca, Malaysia

    International Nuclear Information System (INIS)

    Wee Boon Siong; Abdul Khalik Hj. Wood

    2007-01-01

    The Strait of Malacca has been a major route for international trade with heavy traffic of large vessels navigating through the narrow waterway everyday. Beside, the Strait of Malacca has some natural ecosystem which requires proper protection from human activities. Therefore, the Malaysian government has initiated a project to monitor the pollution level at the Strait of Malacca. As a result, sampling expeditions had been conducted to collect marine samples to be analyzed for trace and toxic elements as well as organic pollutions and radionuclides. The focus of this report is to determine trace and toxic element concentration in surface sediment samples collected from 18 sampling locations at the Strait of Malacca was reported. (author)

  11. Trace element composition and distribution in micron area of dinosaur eggshell fossils determined by proton microprobe

    International Nuclear Information System (INIS)

    Chen Youhong; Zhu Jieqing; Wang Xiaohong; Wang Yimin

    1997-01-01

    The scanning proton microprobe and micro-PIXE quantitative analysis technique have been used to determine composition and distribution of the trace elements in micron areas of dinosaur eggshell fossils from the stratum of Upper Cretaceous system at Nanxiong Basin in Guangdong Province, China. The study shows that the trace elements mainly include Ti, V, Cr, Mn, Co, Ni, Cu, Zn, As, Rb, Sr, Y, Zr, Sb, Ba and Pb in the micron area, but they present different distributions. While the element Sr is mainly enriched in the near surface layer, others mainly reside in the near inner layer. A preliminary discussion on the reason of the dinosaur extinction is given based on the above study

  12. Trace element composition and distribution in micron area of dinosaur eggshell fossils determined by proton microprobe

    International Nuclear Information System (INIS)

    Chen Youhong; Zhu Jieqing; Wang Xiaohong; Wang Yimin

    1997-01-01

    The scanning proton microprobe and micro-PIXE quantitative analysis technique have been used to determine composition and distribution of the trace elements in micron areas of dinosaur eggshell fossils from the stratum of Upper Cretaceous system at Nanxiong Basin in Guangdong Province, China. The study shows that the trace elements mainly include Ti, V, Cr, Mn, Co, Ni, Cu, Zn, As, Rb, Sr, Y, Zr, Sb, Ba and Pb in the micron area, but they present different distributions. While the elements Sr is mainly enriched in the near surface layer, others mainly reside in the near inner layer. A preliminary discussion on the reason of the dinosaur extinction is given based on the above study

  13. (F)UV Spectroscopy of K648: Abundance Determination of Trace Elements

    Science.gov (United States)

    Mohamad-Yob, S. J.; Ziegler, M.; Rauch, T.; Werner, K.

    2010-11-01

    We present preliminary results of an ongoing spectral analysis of K 648, the central star of the planetary nebula Ps 1, based on high resolution FUV spectra. K 648, in M 15 is one of only four known PNe in globular clusters. The formation of this post-AGB object in a globular cluster is still unclear. Our aim is to determine Teff, log g, and the abundances of trace elements, in order to improve our understanding of post-AGB evolution of extremely metal-poor stars, especially PN formation in globular clusters. We analyzed FUSE, HST/STIS, and HST/FOS observations. A grid of stellar model atmospheres was calculated using the Tübingen NLTE Model Atmosphere Package (TMAP).

  14. Determination of trace elements: Neutron-activation analysis in geochemistry and cosmochemistry

    International Nuclear Information System (INIS)

    Kolesov, G.M.

    1994-01-01

    Geochemistry, like cosmochemistry, open-quotes studies chemical elements hor-ellipsis of the crust and hor-ellipsis the Earth hor-ellipsis their history, their distribution hor-ellipsis their genetic hor-ellipsis connectionsclose quotes and is based on data on the abundance and distribution of elements obtained by various analytical methods. Neutron-activation analysis (NAA) plays a particular role in this respect. This is due to its high sensitivity (detection limit as small as 10 -14 g), which makes possible the use of samples of arbitrary mass, and also due to the possibility of obtaining information about composition without destruction of the object, conserving, if required, the unique material under investigation. Of the most interest are the data on the contents for a number of trace elements (at a level of 10 -7 - 10 -4 %), among which are rare-earth elements (REE), U, Th, Zr, Hf, Ta, W, Ga, Ni, Rb, Cs, platinum-group metals, Ag, Au, etc. These elements are considered as indicators of geochemical processes associated with the genesis and evolution of solar system bodies in early and more recent stages of evolution; they are also used to study processes and phenomena at zone boundaries: river-sea, ocean-atmosphere, and so on. The aim of this work is to show the capabilities of NAA in the determination of trace elements

  15. Preliminary investigation on determination of radionuclide distribution in field tracing test site

    International Nuclear Information System (INIS)

    Tanaka, Tadao; Mukai, Masayuki; Takebe, Shinichi; Guo Zede; Li Shushen; Kamiyama, Hideo.

    1993-12-01

    Field tracing tests for radionuclide migration have been conducted by using 3 H, 60 Co, 85 Sr and 134 Cs, in the natural unsaturated loess zone at field test site of China Institute for Radiation Protection. It is necessary to obtain confidable distribution data of the radionuclides in the test site, in order to evaluate exactly the migration behavior of the radionuclides in situ. An available method to determine the distribution was proposed on the basis of preliminary discussing results on sampling method of soils from the test site and analytical method of radioactivity in the soils. (author)

  16. Total reflection X-ray fluorescence as a convenient tool for determination of trace elements in microscale gasoline and diesel

    Science.gov (United States)

    Zhang, Airui; Jin, Axiang; Wang, Hai; Wang, Xiaokang; Zha, Pengfei; Wang, Meiling; Song, Xiaoping; Gao, Sitian

    2018-03-01

    Quantitative determination of trace elements like S, Fe, Cu, Mn and Pb in gasoline and S in diesel is of great importance due to the growing concerns over air pollution, human health and engine failure caused by utilization of gasoline and diesel with these harmful elements. A method of total reflection X-ray fluorescence (TXRF) was developed to measure these harmful trace elements in gasoline and diesel. A variety of factors to affect measurement results, including TXRF parameters, microwave-assisted digestion conditions and internal standard element and its addition, were examined to optimize these experimental procedures. The hydrophobic treatment of the surface of quartz reflectors to support the analyte with neutral silicone solutions could prepare thin films of gasoline and diesel digestion solutions for subsequent TXRF analysis. The proposed method shows good potential and reliability to determine the content of harmful trace elements in gasoline and diesel with high sensitivity and accuracy without drawing different standard calibration curves, and can be easily employed to screen gasoline and diesel in routine quality control and assurance.

  17. Determination of base-line levels of trace amounts in pulses and spices using neutron activation technique

    International Nuclear Information System (INIS)

    Zaidi, J.H.; Arif, M.; Fatima, I.; Qureshi, I.H.

    1993-01-01

    It has been established that essential trace elements are vitally important for biochemical systems, whereas toxic elements if present in relatively higher amounts adversely affect these systems. Trace elements reach the human body mainly through foodstuffs. The different articles contain varying amount of toxic and essential elements. It is therefore necessary to asses the adequacy and safety of the diet by determining the base-line levels of these elements. In continuation of our previous work, some varieties of pulses and spices were analyzed using neutron activation technique. Among the four varieties of pulses lentil (lens esculenta) was found to contain higher amounts of essential elements and lower amounts of toxic elements. The daily intake of essential and toxic elements through pulses was estimated and compared with the suggested values. The estimated intake of essential elements is adequate and that of toxic elements is well below the tolerance limit. In spices cumin and caraway seeds were found to contain relatively higher amounts of essential as well as toxic elements. The studies showed that food spices were additional source of trace element intake. (author)

  18. Determination of trace aluminum by fluorescence quenching method based on catalysis of potassium chlorate oxidizing alizarin red

    Science.gov (United States)

    Shao-Qin, Lin; Xuan, Lin; Shi-Rong, Hu; Li-Qing, Zeng; Yan, Wang; Li, Chen; Jia-Ming, Liu; Long-Di, Li

    2005-11-01

    A new method for the determination of trace aluminum has been proposed. It is based on the fact that alizarin red can emit strong and stable fluorescence at 80 °C for 30 min and Al 3+ can effectively catalyze potassium chlorate oxidizing alizarin red to form non-fluorescence complex which cause the fluorescence quenching. The linear dynamic range of this method is 0.040-4.00 ng l -1 with a detection limit of 5.3 pg l -1. The regression equation can be expressed as Δ If = 8.731 + 21.73 c (ng l -1), with the correlation coefficient r = 0.9992 ( n = 6). This sensitive, rapid and accurate method has been applied to the determination of trace aluminum(III) in human hair and tea samples successfully. What is more, the mechanism of catalyzing potassium chlorate oxidizing alizarin red by the fluorescence quenching method is also discussed.

  19. Development of a choronocoulometric method for determining traces of uranium using the catalytic nitrate reduction

    International Nuclear Information System (INIS)

    Cantagallo, M.I.C.; Gutz, I.G.R.

    1990-01-01

    With the aim of improving the sensitivity of the electroanalytical determination of uranium at trace levels. The uranium catalyzed reduction of nitrate on mercury electrode and the technique of chronocoulometry were used. Several experimental parameters were investigated (electrolyte composition, potential program, integration time, blank correction, temperature, previous separation) and adequate conditions were selected for the analytical determination. Under these conditions it was possible to exceed the best reported sensitivity for the catalytic determination, extending the detection limit to 3.10 -10 M. Exploratory study of the combination of this procedure with pre-concentration of uranium ions on the electrode revealed a detection limit ten limes lower. (author) [pt

  20. Density determination of nail polishes and paint chips using magnetic levitation

    Science.gov (United States)

    Huang, Peggy P.

    Trace evidence is often small, easily overlooked, and difficult to analyze. This study describes a nondestructive method to separate and accurately determine the density of trace evidence samples, specifically nail polish and paint chip using magnetic levitation (MagLev). By determining the levitation height of each sample in the MagLev device, the density of the sample is back extrapolated using a standard density bead linear regression line. The results show that MagLev distinguishes among eight clear nail polishes, including samples from the same manufacturer; separates select colored nail polishes from the same manufacturer; can determine the density range of household paint chips; and shows limited levitation for unknown paint chips. MagLev provides a simple, affordable, and nondestructive means of determining density. The addition of co-solutes to the paramagnetic solution to expand the density range may result in greater discriminatory power and separation and lead to further applications of this technique.

  1. A simple chemical method for the separation of phosphorus interfering the trace element determinations by neutron activation analysis in high doped silicon wafers

    International Nuclear Information System (INIS)

    Wagler, H.; Flachowsky, J.

    1986-01-01

    Neutron activation analysis is one of the most available method for the determination of trace elements, but in the case of P-doped silicon wafers the 32 P-activity interferes the gamma spectrometry. It is not possible to determine the trace elements without chemical manipulations. On the other hand, time consuming chemical separations should be avoided. Therefore, a simple and rapid P-separation method has to be developed, in which the following twelve trace elements should be taken into consideration: Ag, As, Au, Co, Cr, Cu, Fe, Mo, Na, Sb, W, and Zn. After acid oxidative dissolution of the activated sample, P is present as phosphate ion. The phosphate ion is removed by precipitation as BiPO 4 . (author)

  2. <<Unknown>> earthquakes: a growing contribution to the Catalogue of Strong Italian Earthquakes

    Directory of Open Access Journals (Sweden)

    E. Guidoboni

    2000-06-01

    Full Text Available The particular structure of the research into historical seismology found in this catalogue has allowed a lot of information about unknown seismic events to be traced. This new contribution to seismologic knowledge mainly consists in: i the retrieval and organisation within a coherent framework of documentary evidence of earthquakes that took place between the Middle Ages and the sixteenth century; ii the improved knowledge of seismic events, even destructive events, which in the past had been "obscured" by large earthquakes; iii the identification of earthquakes in "silent" seismic areas. The complex elements to be taken into account when dealing with unknown seismic events have been outlined; much "new" information often falls into one of the following categories: simple chronological errors relative to other well-known events; descriptions of other natural phenomena, though defined in texts as "earthquakes" (landslides, hurricanes, tornadoes, etc.; unknown tremors belonging to known seismic periods; tremors that may be connected with events which have been catalogued under incorrect dates and with very approximate estimates of location and intensity. This proves that this was not a real seismic "silence" but a research vacuum.

  3. Laser-time resolved fluorimetric determination of trace of boron in U3O8

    International Nuclear Information System (INIS)

    Xu Yongyuan; Wang Yulong; Wang Qin

    1988-01-01

    In this work, a laser-time resolved fluorimetric determinatin of trace of boron in U 3 O 8 had been developed. The boron complex with dibenzoyl methane (DBM) in a suitable medium is excited by a small nitrogen laser and emits the delay fluorescence with lifetime of 2 ms which is much longer than that of the fluorescence of uranium. Since the fluorescence of uranium doesn't interfere with determination of boron in the time resolved fluorimetric method boron need not be separated from uranium in advance. Thus the determination is very rapid and simple. The limit of determination is 0.02 ngB/ml. When 10 mgU is taken, 0.01 ppm of boron in uranium can be determined. Several samples of U 3 O 8 with boron content from 0.04 to 0.5 ppm have been determined by using this method. The results of determination have been accordant with other methods

  4. Present and Future Challenges in Trace and Ultra-Trace Analysis

    International Nuclear Information System (INIS)

    Toulhoat, P.

    2005-01-01

    The analysis of trace and ultra-trace elements is continuously stimulating the progress in analytical chemistry. Environmental chemistry, radiochemistry, biology, health, agri-food are prescribers of trace analyses, with continuously increasing exigencies: lowering detection limits, lowering costs and analysis time, improving the quality of analytical information. Precise data about the chemical identity and chemical environment of analytes are now requested. Such pieces of information, beyond simple numerical data and confidence intervals, are necessary to understand studied systems, and to predict their evolution. From environmental contamination cases, one can envisage the various aspects of a problem, with for each of them its own exigencies and specificities in terms of analytical methods and approaches. The detection of traces and ultra-traces of actinides and fission products has been recently revisited and stimulates new technological developments (non proliferation issues, waste management). Data on their speciation in geological and biological media are essential for evaluating the safety of nuclear waste repositories. Various techniques are now used to determine speciation in liquid samples or on surfaces, with tremendous spatial resolutions or sensitivities. A new revolution in analytical chemistry is expected with the development of micro- or nano-analytical technologies. (author)

  5. Texture one zero Dirac neutrino mass matrix with vanishing determinant or trace condition

    Science.gov (United States)

    Singh, Madan

    2018-06-01

    In the light of non-zero and relatively large value of rector mixing angle (θ13), we have performed a detailed analysis of texture one zero neutrino mass matrix Mν in the scenario of vanishing determinant/trace conditions, assuming the Dirac nature of neutrinos. In both the scenarios, normal mass ordering is ruled out for all the six possibilities of Mν, however for inverted mass ordering, only two are found to be viable with the current neutrino oscillation data at 3σ confidence level. Numerical and some approximate analytical results are presented.

  6. Multielement determination of trace elements in seawater by inductively coupled plasma mass spectrometry after tandem preconcentration with cooperation of chelating resin adsorption and lanthanum coprecipitation

    International Nuclear Information System (INIS)

    Yabutani, Tomoki; Chiba, Koichi; Haraguchi, Hiroki

    2001-01-01

    A tandem preconcentration method, in which chelating resin adsorption and La coprecipitation were cooperatively employed for preconcentration, was developed as a pretreatment method for simultaneous multielement determination of trace elements in seawater by ICP-MS. First, the seawater sample (250 ml) was treated with a chelating resin for preconcentration of trace elements, and then trace elements with good recoveries were determined by ICP-MS. Trace elements with the chemical properties of oxoanion- and hydride-formation, which were poorly recovered in the chelating resin preconcentration, were further subjected to preconcentration by La coprecipitation. As a result, more than 30 elements could be determined in the concentration range from 9.6 μg L -1 for Mo to 0.00018 μg L -1 for Tm, when the present tandem method was applied to the analysis of open seawater standard reference material (NASS-4). Furthermore, the analytical results for open seawater reference materials were compared with those for coastal seawater reference material as well as for coastal seawater collected in the Ise Bay. It was found that the multielement data for trace elements in these seawater samples clearly showed different elemental distributions, reflecting the different marine environments. (author)

  7. Determination of trace metals in Cladophora glomerata: C. glomerata as a potential biological monitor

    Energy Technology Data Exchange (ETDEWEB)

    Keeny, W.L.; Breck, W.G.; Vanloon, G.W.; Page, J.A.

    1976-01-01

    A differential pulse anodic stripping voltammetry method has been developed for the determination of Zn, Cd, Pb and Cu in Cladophora glomerata. The method has been applied to samples taken in August from a remote island in Lake Ontario (Main Duck) and a shore site near Kingston, Ontario (Deadman Bay). It is postulated that C. glomerata can act as a biological monitor, concentrating the trace metals present in the aqueous environment with a reasonably constant CF for each element.

  8. The determination of minor isotope abundances in naturally occurring uranium materials. The tracing power of isotopic signatures for uranium

    Energy Technology Data Exchange (ETDEWEB)

    Ovaskainen, R

    1999-11-01

    Atomic Energy Agency (IAEA) from uranium milling and mining facilities (Australia, Canada, Gabon, Namibia, Czech Republic, France), were determined. These signatures form the basic register. The isotopic signatures are feasible in identifying the sample origin and in separating naturally occurring or background contributions from local anthropogenic sources. With the comparison of fingerprints of unknown samples to the isotopic fingerprints of samples of known origin, it is possible to trace back unknown samples to their origin or at least to exclude suspected origins in the case of non-identity of fingerprints. This was successfully demonstrated with a number of samples of unknown origin, which were measured during the study. Generally, no significant variability was observed in the n({sup 235}U)/n({sup 238}U) ratios except in the well known case of samples originating from Oklo (Gabon). Small variations in the n({sup 234}U)/n({sup 238}U) amount ratios were understood from the radiochemical mother-daughter relationship of the two isotopes involved. The detection limit for the n({sup 236}U)/n({sup 235}U) amount ratio (DL = 0.000001) was derived from blank measurements. The limit of quantitation 0.000003 was calculated as LQ=3DL. When the measured ratio exceeded the quantitation limit, the presence of {sup 236}U is explained. (orig.) 99 refs.

  9. Trace element determination in fingernails, hair and blood serum in patients with Crohn's disease using neutron activation analysis

    International Nuclear Information System (INIS)

    Buschmann, H.

    1984-01-01

    The determination of trace elements and electrolyte concentrations in blood serum, hair and fingernails of 16 patients with Crohn's disease was carried out by means of instrumental neutron activation analysis. In the serum a significant decline in the zinc content could be registered, while the remaining trace elements remained in the normal range. The parenteral nutrition also showed a zinc deficiency. There was, however, also an iron deficiency. The studies of the hair and fingernails gave the following results: Rubidium and antimony in the normal range; zinc, selenium, iron and cobalt below normal values. (orig./PW) [de

  10. Activation analytical determination of essential and toxic trace elements in biological material

    International Nuclear Information System (INIS)

    Schelenz, R.

    1980-01-01

    In order to determine the essential trace elements Hg, Ag, Cu and Se in food (potatoes, milk powder) and biological standard materials (fruit tree leaves), simple, fast radiochemical separation methods are worked out. Following oxidative decomposition and destillation of Hg, the elements silver, copper and selenium are found in the destillation residue and can be electrochemically enriched on an amalgamated Cu foil (determination of Ag and Se in the concentration range of 10 -9 to 10 -8 g, of Cu in the range of 10 -12 to 10 -10 g), whilst the matrix elements Na, K, P are adsorbed on a column with 3 different inorganic ion exchangers. The eluate of the ion exchanger can be added directly to the multielement gamma spectroscopy. The possiblity of working purely instrumentally is demonstrated by 2 examples: multielement analysis of human hair and river water. (RB) [de

  11. Determination of trace elements in soil and plants in the Orontes basin of Syria by using instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Kassem, A.; Sarheel, A.; Al-Somel, N.

    2004-01-01

    Instrumental neutron activation analysis (INAA) have been used for the determination of some major, minor and trace elements (As, Cr, Co, Ni, Zn, Sb, Sc, Ce, Ti, Fe, Mn and V) in various plant leaves together with their soil. The accuracy of the measurements have been evaluated by analyzing a number of plant and soil reference materials, precision have been estimated by triplicate analysis of the sample as well as that of the reference material. The obtained accurate and reliable data of some trace elements on microgram level for plants and soil will serve as baseline values and will be helpful to monitor the changes in the trace element content of soil and plant leaves. (author)

  12. Determination of rhenium traces in river water by Q-ICP-MS and HR-ICP-MS

    International Nuclear Information System (INIS)

    Uchida, S.; Tagami, K.; Saito, M.

    2003-01-01

    A simple separation method was applied to determine rhenium in river water using Q-ICP-MS and HR-ICP-MS. Re was concentrated from 420-925 ml river water using a TEVA resin minicolumn. Such extraction using a resin could separate Re from most sample matrices and trace elements. Almost 100% recovery was found throughout the method as determined with radioactive multitracers. The HR-ICP-MS was also used for the direct determination because of its low detection limit for Re (0.007 pg/ml). The Re concentration in the river water samples ranged from 0.9 to 6.5 pg/ml and the three analysis results showed good agreement with each other. (author)

  13. Report on intercomparison V-8 of the determination of trace elements in rye flour

    International Nuclear Information System (INIS)

    Pszonicki, L.; Veglia, A.; Dybczynski, R.; Suschny, O.

    1982-01-01

    The participants were requested to determine as many elements as they could from among the following 29: As, Be, Ca, Cd, Cl, Co, Cr, Cu, F, Fe, Ga, Hg, I, K, Mg, Mn, Mo, Na, Ni, P, Pb, Sb, Se, Si, Sn, Tl, U, V and Zn. While six of these elements (Be, Ga, Sn, Tl, U, V) were not determined by any laboratory, some participants on the other hand determined several elements which had not been ordered for such as As, Al, Au, Ba, Br, Cs, Eu, La, N, Rb, S, Sc, Sr, Ti and Y. In total, 34 laboratories submitted results of 1,207 individual determinations (301 laboratory means) on 38 elements. The methods most often employed in this intercomparison were neutron activation analysis (47% of all results) and atomic absorption (20%). The results of the intercomparison demonstrated again the difficulties in the determination of trace elements in organic materials. The agreement between participating laboratories was in general poor

  14. A hard tissue cephalometric comparative study between hand tracing and computerized tracing

    Directory of Open Access Journals (Sweden)

    Ramachandra Prabhakar

    2014-01-01

    Full Text Available Aims: To analyze and compare the angular and linear hard tissue cephalometric measurements using hand-tracing and computerized tracings with Nemoceph and Dolphin software systems. Subjects and Methods: A total of 30 cephalograms were randomly chosen for study with the following criteria, cephalograms of patients with good contrast, no distortion, and minimal radiographic artifacts were considered using the digital method (Kodak 8000 C with 12 angular and nine linear parameters selected for the study. Comparisons were determined by post-hoc test using Tukey HSD method. The N-Par tests were performed using Kruskal-Walli′s method. Statistical Analysis Used: ANOVA and post-hoc. Results: The results of this study show that there is no significant difference in the angular and linear measurements recorded. The P values were significant at 0.05 levels for two parameters, Co-A and Co-Gn with the hand-tracing method. This was significant in ANOVA and post-hoc test by Tukey HSD method. Conclusions: This study of comparison provides support for transition from digital hand to computerized tracing methodology. In fact, digital computerized tracings were easier and less time consuming, with the same reliability irrespective of each method of tracing.

  15. Determination of trace elements in Katana (Japanese sword) by neutron activation analysis with multidimensional γ-ray spectrometry

    International Nuclear Information System (INIS)

    Okada, Y.; Hirai, S.; Ohya, S.; Kimura, Atsushi; Hatsukawa, Yuichi; Toh, Yosuke; Koizumi, Mitsuo; Oshima, Masumi

    2006-01-01

    In this study, we tried to measure trace elements (As and Sb) in Katana (Japanese swords) by multidimensional γ-ray spectrometry method (GEMINI-II) and conventional counting method for neutron activation analysis (NAA). The determined values by GEMINI-II and conventional counting were in good agreement with. Using the multidimensional γ-ray spectrometry (GEMINI-II) to determine As and Sb was improved by 7 times and 10 times compared with the conventional counting method. (author)

  16. A simple spectrophotometric determination of trace amounts of vanadium using thionin

    Directory of Open Access Journals (Sweden)

    Tom Cherian

    2005-12-01

    Full Text Available A simple and sensitive spectrophotometric method has been developed for the determination of trace amounts of vanadium using thionin as a chromogenic reagent. The proposed method is based on the reaction of vanadium(V with potassium iodide in acid medium to liberate iodine, which bleaches the violet colour of thionin and is measured at 600 nm. This decrease in absorbance is directly proportional to the vanadium(V concentration and obeys Beer's law in the range of 0.2-10 μgmL-1 of V(V. The molar absorptivity, Sandell's sensitivity, detection limit and quantitation limit of the method were found to be 2.298 x 104 Lmol-1cm-1, 0.52 x 10-2 μgcm-2, 0.035 μgmL-1 and 0.11 μgmL-1, respectively. The optimum reaction conditions and other analytical conditions were evaluated. The effect of interfering ions on the determination is described. The developed method has been successfully applied to the analysis of the vanadium in synthetic and alloy samples.

  17. Kinetic method of ruthenium ion traces determination, basing on the reaction of oxidation of direct blue 6B, by means of hydrogen peroxide

    International Nuclear Information System (INIS)

    Suwinska, T.; Gregorowicz, A.; Matysek-Majewska, D.

    1980-01-01

    A sensitive and selective method of determination of ruthenium ion traces (1.10 - 3 μg/cm 3 ) has been worked out. The method is based on oxidation of direct blue 6B by hydrogen peroxide under acidic conditions at pH = 0,8 - 1,2 in the presence of ruthenium ions as catalyst. The method has been applied for determination of ruthenium traces in Pt, PdCl 2 , PtCl 4 and RhCl 3 .n H 2 O. In these materials ruthenium has been determined within the range of 1,10 - 2 % - 5,10 - 4 %. (author)

  18. The IAEA worldwide intercomparison exercises (1990-1997). Determination of trace elements in marine sediments and biological samples

    International Nuclear Information System (INIS)

    Coquery, M.; Carvalho, F.P.; Azemard, S.; Horvat, M.

    1999-01-01

    Four major worldwide intercomparison exercises for the determination of trace elements in various environmental matrices were completed by the IAEA Marine Environment Laboratory since 1990: SD-M-2/TM, deep sea marine sediment; IAEA-350, tuna fish homogenate; IAEA-356, contaminated coastal sediment and IAEA-140, sea plant (Fucus sp.). These intercomparison exercises aim at enabling individual laboratories to monitor their performance. The results of these exercises allowed us to make an overall evaluation of the quality of data provided for environmental assessment and to identify the trends of analytical performance in the determination of trace elements over the years. The number of participants in each exercise varied between 68 and 130, and permits statistical evaluation of the performance for a number of elements. For each intercomparison exercise, the performance of the participant laboratories was assessed by comparing reported results with established reference values calculating 'Z-scores'. The results show that for each sample matrix, the values reported by some laboratories were far from satisfactory in the earlier exercises, in particular for Cd, Cr and Pb. Nevertheless, over time, a general improvement of performance can clearly be seen for all elements. Moreover, there was a noticeable increase in the number of laboratories with good performance in the two most recent exercises, observed both for biological and for sediment matrices. However, the determination of trace elements such as Cd, Cr, Pb and Hg in low level environmental samples still remains a major challenge to the analysts. For this reason and in order to assess the current performance of laboratories for low environmental levels of contaminants, the future intercomparison exercises will concentrate on low level sediment and fish samples

  19. Determination of trace amounts of selenium in minerals and rocks by flemeless atomic-absorption spectrometry

    International Nuclear Information System (INIS)

    Capdevila, C.; Alduan, F.A.

    1980-01-01

    The determination of trace amounts of selenium in silicate rocks and feldspart by solvent extraction and graphite furnace atomic-absorption spectrometry has been studied. Sodium diethyl-ditiocarbamate and ammonium pyrrolidinedithiocarbamate have been tried as chelating agents. The best results are achieved when selenium is extracted into carbon tetrachloride as the sodium diethylditiocarbamate complex. The method allows to detect 0,75 ppm of selenium in the sample. Recoveries are about 100%. (author)

  20. A radioagent method for determination of traces of phosphorus in high-purity silicon

    International Nuclear Information System (INIS)

    Chen, P.Y.; Chen, J.S.; Sun, H.J.; Yang, M.H.

    1985-01-01

    The feasibility of the determination of phosphorus at the extreme trace levels in high-purity silicon by radioreagent method is explored. After silicon dissolution with hydrofluoric and nitric acids and matrix volatilization, 12-molybdophosphoric acid is formed by the addition of the reagent, sup(99)MoOsub(4)sup(2-), in nitric acid medium and then extracted into isobutyl acetate. By plotting the phosphorus content against the radioactivity of sup(99)Mo in the organic phase, a linear relationship persisting down to 5 ng is obtained. Special effort was made to eliminate the unreacted sup(99)MoOsub(4)sup(2-) reagent and the optimal control of phosphorus blank introduced through the multistage analytical procedure in order to ensure reliable determination of phosphorus at the ppb level. (author)

  1. [Determination of trace lead and cadmium in transgenic rice by crosslinked carboxymethyl konjac glucomannan microcolumn preconcentration combined with graphite furnace atomic absorption spectrometry].

    Science.gov (United States)

    Liu, Hua-qing; Li, Sheng-qing; Qu, Yang; Chen, Hao

    2012-02-01

    A novel method was developed for the determination of trace lead and cadmium in transgenic brown rice based on separation and preconcentration with a micro column packed with crosslinked carboxymethyl konjac glucomannan (CCMKGM) prior to its determination by graphite furnace atomic absorption spectrometry. Variables affecting the separation and preconcentration of lead and cadmium, such as the acidity of the aqueous solution, sample flow rate and volume, and eluent concentration and volume, were optimized. Under optimized condition, detection limits of the method for the determination of trace lead and cadmium in transgenic brown rice were 0.11 and 0.002 microg x L(-1), respectively. The obtained results of lead and cadmium in the certified reference material (GBW10010, GBS1-1) were in good agreement with the certified values. The recoveries were in the range of 90%-103% and 93%-105% for detection of Pb and Cd in transgenic brown rice and the wild-type brown rice samples respectively. This study could provide technical support for determination of trace Pb and Cd in transgenic rice.

  2. Trace element determination in tomato puree using particle induced X-ray emission and Rutherford backscattering

    International Nuclear Information System (INIS)

    Romero-Davila, E.; Miranda, J.

    2004-01-01

    Particle induced X-ray emission (PIXE) and Rutherford backscattering spectrometry (RBS) were used to determine the concentrations of trace elements in samples of 12 tomato puree brands sold in the Mexican market. While RBS offered information about the main elements present in the matrix, PIXE gave results on trace elements. As a whole, data for 17 elements (C, N, O, Na, Mg, S, Cl, K, Ca, Ti, V, Cr, Mn, Fe, Ni, Cu, and Zn) were obtained. To evaluate the results, a comparison with brands from USA, Japan, Colombia, and Chile was carried out, using tomato purees produced following the domestic technology recipe. Additionally, the results were considered in the light of the Codex Alimentarius and the Mexican standard. It was found that all of the brands fall within the limits established by these standards, being of the same order of magnitude as the foreign brands. (author)

  3. Preconcentration and Speciation of Trace Elements and Trace-Element Analogues of Radionuclides by Neutron Activation Analysis

    International Nuclear Information System (INIS)

    Chatt, A.

    1999-01-01

    We have developed a number of preconcentration neutron activation analysis (PNAA) methods in our laboratory for the determination of trace elements in a variety of complex sample matrices. We developed a number of cocrystallization and coprecipitation methods for the determination of trace elements in water samples. We developed several methods for the determination of I in foods and diets. We have developed a number of PNAA methods in our laboratory We determined As and Sb in geological materials and natural waters by coprecipitation with Se and Au in silicate rocks and ores by coprecipitation with Te followed by NAA. We developed an indirect NAA method for the determination of B in leachates of borosilicate glass. We have been interested in studying the speciation of Am, Tc, and Np in simulated vitrified groundwater leachates of high-level wastes under oxid and anoxic conditions using a number of techniques. We then used PNAA methods to study speciation of trace-element analogues of radionuclides. We have been able to apply biochemical techniques and NAA for the separation, preconcentration, and characterization of metalloprotein and protein-bound trace-element species in subcellular fractions of bovine kidneys. Lately, we have concentrated our efforts to develop chemical and biochemical methods in conjunction with NAA, NMR, and MS for the separation and identification of extractable organohalogens (EOX) in tissues of beluga whales, cod, and northern pink shrimp

  4. Nuclear traces in glass

    International Nuclear Information System (INIS)

    Segovia A, M. de N.

    1978-01-01

    The charged particles produce, in dielectric materials, physical and chemical effects which make evident the damaged zone along the trajectory of the particle. This damaged zone is known as the latent trace. The latent traces can be enlarged by an etching of the detector material. This treatment attacks preferently the zones of the material where the charged particles have penetrated, producing concavities which can be observed through a low magnification optical microscope. These concavities are known as developed traces. In this work we describe the glass characteristics as a detector of the fission fragments traces. In the first chapter we present a summary of the existing basic theories to explain the formation of traces in solids. In the second chapter we describe the etching method used for the traces development. In the following chapters we determine some chatacteristics of the traces formed on the glass, such as: the development optimum time; the diameter variation of the traces and their density according to the temperature variation of the detector; the glass response to a radiation more penetrating than that of the fission fragments; the distribution of the developed traces and the existing relation between this ditribution and the fission fragments of 252 Cf energies. The method which has been used is simple and cheap and can be utilized in laboratories whose resources are limited. The commercial glass which has been employed allows the registration of the fission fragments and subsequently the realization of experiments which involve the counting of the traces as well as the identification of particles. (author)

  5. Trace Element Determination and Cardioprotection of Terminalia pallida Fruit Ethanolic Extract in Isoproterenol Induced Myocardial Infarcted Rats by ICP-MS.

    Science.gov (United States)

    Althaf Hussain, Shaik; Kareem, Mohammed Abdul; Rasool, Shaik Nayab; Al Omar, Suliman Yousef; Saleh, Alwasel; Al-Fwuaires, Manal Abdulrahman; Daddam, Jayasimha Rayalu; Devi, Kodidhela Lakshmi

    2018-01-01

    The trace elements and minerals in Terminalia pallida fruit ethanolic extract (TpFE) were determined by the instrument inductively coupled plasma-mass spectrometry (ICP-MS), and the cardioprotection of TpFE against isoproterenol (ISO)-administered rats was studied. Rats were pretreated with TpFE (100, 300, and 500 mg/kg bw) for 30 days, with concurrent administration of ISO (85 mg/kg bw) for two consecutive days. The levels of trace elements and minerals in TpFE were below the permitted limits of World Health Organization standards. ISO administration significantly increased the heart weight and cardiac marker enzymes in serum, xanthine oxidase, sodium, and calcium in the heart, whereas significantly decreased body weight, reduced glutathione, glutathione-S-transferase, superoxide dismutase, and potassium in the heart. Oral pretreatment of TpFE significantly prevented the ISO-induced alterations. This is the first report that revealed the determination of trace elements and mineral nutrients of TpFE by ICP-MS which plays a principal role in the herbal drug discovery for the treatment of cardiovascular diseases.

  6. Determination of trace amounts of metals in saline water by energy-dispersive XRF (with the Na-DDTC preconcentration)

    International Nuclear Information System (INIS)

    Holynska, B.; Bisiniek, K.

    1975-01-01

    A simple method for the determination of trace concentrations of metals in saline water is described. The analytical procedure involves the separation of metal ions of Cu(2), Zn(2), Hg(2) and Fe(3) by precipitation with diethyldithiocarbamate (DDTC). The radioisotope X-ray fluorescence method using Si/Li detector has been applied for the determination of metal ions closed in the DDTC deposition. (author)

  7. Determination and statistical analysis of trace element and active constituent concentrations in the medicinal plant Eucalyptus camaldulensis Dehnh (E. rostratus Schlecht)

    International Nuclear Information System (INIS)

    Kanias, G.D.; Kilikoglou, V.; Tsitsa, E.; Loukis, A.

    1993-01-01

    In the leaves of the medicinal plant Eucalyptus camaldulensis Dehnh (E. rostratus Schlecht) collected from different sampling areas of Greece the trace elements antimony, cesium, chromium, cobalt, iron, europium, rubidium scandium, strontium, thorium and zinc were determined by Instrumental Neutron Activation Analysis. In the same samples, the essential oil was determined by steam distillation and the percent relative composition of the essential oil in 1,8-cineole, p-cymene, α-pinene by gas liquid chromatography. Also the refractive index of the essential oil was determined by a refractometer. Statistical analysis included the calculation of the correlation coefficient. Multiple correlation and cluster analysis was applied to all analytical data. The results showed that the trace elements iron, chromium, cobalt and zinc are correlated with the variation of the concentration of essential oil in the examined plant. These four elements along with rubidium and essential oil content could be used for the separation of the samples into groups related to the sampling areas. Statistically significant correlation between active constituents and some trace elements and a linear negative correlation between 1,8-cineole and refractive index were found. (author) 13 refs.; 2 figs.; 2 tabs

  8. Identification case of evidence in timber tracing of Pinus radiate, using high-resolution melting (HRM) analysis.

    Science.gov (United States)

    Solano, Jaime; Anabalón, Leonardo; Encina, Francisco

    2016-03-01

    Fast, accurate detection of plant species and their hybrids using molecular tools will facilitate assessment and monitoring of timber tracing evidence. In this study the origin of unknown pine samples is determined for a case of timber theft in the region of Araucania southern Chile. We evaluate the utility of the trnL marker region for species identification applied to pine wood based on High Resolution Melting. This efficient tracing methods can be incorporated into forestry applications such as certification of origin. The object of this work was genotype identification using high-resolution melting (HRM) and trnL approaches for Pinus radiata (Don) in timber tracing evidence. Our results indicate that trnL is a very sensitive marker for delimiting species and HRM analysis was used successfully for genotyping Pinus samples for timber tracing purposes. Genotyping samples by HRM analysis with the trnL1 approach allowed us to differentiate two wood samples from the Pinaceae family: Pinus radiata (Don) and Pseudotsuga menziesii (Mirb.) Franco. The same approach with Pinus trnL wood was not able to discriminate between samples of Pinus radiata, indicating that the samples were genetically indistinguishable, possibly because they have the same genotype at this locus. Timber tracing with HRM analysis is expected to contribute to future forest certification schemes, control of illegal trading, and molecular traceability of Pinus spp. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  9. Thermometric Titration for Rapid Determination of Trace Water in Jet Fuel

    Directory of Open Access Journals (Sweden)

    Jian-Qiang Hu

    2017-01-01

    Full Text Available Water content in jet fuels is detected by thermometric titration (TMT, and the optimal detected system is 2,2-dimethoxypropane as titrant, cyclohexane and isopropanol as titration solvents, and methanesulfonic acid as catalyst in this method. The amounts of oil, concentration and delivery rate of titrant, volumes, and the reliability and accuracy of thermometric titration were emphasized. The results show that the accuracy, validity, and reliability of TMT are excellent by different indicated spiked water contents. The obtained results between TMT and Karl Fischer titration have been proven to be in accord. But, the duration of titration merely spends 3–5 min in the whole process, greatly shortening the detected time. Therefore, rapid and accurate determination of trace water in a jet fuel can be realized by TMT.

  10. Determination of toxic trace elements in body fluid reference samples

    International Nuclear Information System (INIS)

    Gills, T.E.; McClendon, L.T.; Maienthal, E.J.; Becker, D.A.; Durst, R.A.; LaFleur, P.D.

    1974-01-01

    The measurement of elemental concentration in body fluids has been widely used to give indication of exposures to certain toxic materials and/or a measure of body burden. To understand fully the toxicological effect of these trace elements on our physiological system, meaningful analytical data are required along with accurate standards or reference samples. The National Bureau of Standards has prepared for the National Institute for Occupational Safety and Health (NIOSH) a number of reference samples containing selected toxic trace elements in body fluids. The reference samples produced include mercury in urine at three concentration levels, five elements (Se, Cu, As, Ni and Cr) in freeze-dried urine at two levels, fluorine in freeze-dried urine at two levels and lead in blood at two concentration levels. These reference samples have been found to be extremely useful for the evaluation of field and laboratory analytical methods for the analysis of toxic trace elements. In particular the use of at least two calibration points (i.e., ''normal'' and ''elevated'' levels) for a given matrix provides a more positive calibration for most analytical techniques over the range of interest for occupational toxicological levels of exposure. (U.S.)

  11. Determination of trace elements in bottled water in Greece by instrumental and radiochemical neutron activation analyses

    International Nuclear Information System (INIS)

    Soupioni, M.J.; Symeopoulos, B.D.; Papaefthymiou, H.V.

    2006-01-01

    Four different bottled water brands sold in Greece in the winter of 2001-2002 were analyzed for a wide range of chemical elements, using neutron activation analysis (NAA). The elements Na and Br were determined instrumentally (INAA), whereas the other metals and trace elements radiochemically (RNAA). The results indicated that the mean level of all the elements determined in the samples were well within the European Union (EU) directive on drinking water and accomplish the drinking water standards of the World Health Organisation (WHO) as well as of the Food and Drug Administration (FDA). (author)

  12. Trace element determination in beauty products by k0-instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Sneyers, L.; Verheyen, L.; Vermaercke, P.; Bruggeman, M.

    2009-01-01

    A recent study on trace elements in beauty products and cosmetics sold on the Asian market has shown the presence of high levels of U, Th and rare earth elements in so called 'Hormesis cosmetics'. For the purpose of comparison, some more information about trace elements in European cosmetics would be useful. In this paper the results obtained using k 0 -standardised Instrumental Neutron Activation Analysis (k 0 -INAA) for more than 20 trace elements in 20 different beauty products collected from the European market are presented. We found traces of Ba, As and Sb which is in breach with European legislation. For some of the other elements like Cr and Co further speciation is needed in order to evaluate their presence in beauty products. (author)

  13. Intraoral gothic arch tracing.

    Science.gov (United States)

    Rubel, Barry; Hill, Edward E

    2011-01-01

    In order to create optimum esthetics, function and phonetics in complete denture fabrication, it is necessary to record accurate maxillo-mandibular determinants of occlusion. This requires clinical skill to establish an accurate, verifiable and reproducible vertical dimension of occlusion (VDO) and centric relation (CR). Correct vertical relation depends upon a consideration of several factors, including muscle tone, inter-dental arch space and parallelism of the ridges. Any errors made while taking maxillo-mandibular jaw relation records will result in dentures that are uncomfortable and, possibly, unwearable. The application of a tracing mechanism such as the Gothic arch tracer (a central bearing device) is a demonstrable method of determining centric relation. Intraoral Gothic arch tracers provide the advantage of capturing VDO and CR in an easy-to-use technique for practitioners. Intraoral tracing (Gothic arch tracing) is a preferred method of obtaining consistent positions of the mandible in motion (retrusive, protrusive and lateral) at a comfortable VDO.

  14. Determination of trace elements by resonant ionization mass spectrometry (RIMS)

    International Nuclear Information System (INIS)

    Ruster, W.; Ames, F.; Rehklau, D.; Mang, M.; Muehleck, C.; Rimke, H.; Sattelberger, P.; Herrmann, G.; Trautmann, N.; Kluge, H.J.; Otten, E.W.

    1988-01-01

    A resonant ionization mass spectrometer has been developed as an analytical tool for the detection of trace elements, especially of plutonium and other radionuclides. The sample, deposited on a rhenium filament, is evaporated by electrical heating and the atoms of the element under investigation are selectively ionized by laser light delivered from three dye lasers pumped by a copper vapour laser. The resulting photoions are detected in a time-of-flight spectrometer with a channelplate detector. For plutonium a mass resolution of M/ΔM=1500 was obtained and an overall detection efficiency of 4x10 -6 was determined for stepwise excitation and ionization via autoionizing states. With a laser light bandwidth of 3-5 GHz neighbouring isotopes could be suppressed by a factor of 20 due to isotope shifts in the excitation transitions. The isotope composition of synthetic samples was measured and good agreement was found with mass spectroscopic results. The influence of the hyperfine structure on the isotope ratios is discussed. (orig.)

  15. Official Methods for the Determination of Minerals and Trace Elements in Infant Formula and Milk Products: A Review.

    Science.gov (United States)

    Poitevin, Eric

    2016-01-01

    The minerals and trace elements that account for about 4% of total human body mass serve as materials and regulators in numerous biological activities in body structure building. Infant formula and milk products are important sources of endogenic and added minerals and trace elements and hence, must comply with regulatory as well as nutritional and safety requirements. In addition, reliable analytical data are necessary to support product content and innovation, health claims, or declaration and specific safety issues. Adequate analytical platforms and methods must be implemented to demonstrate both the compliance and safety assessment of all declared and regulated minerals and trace elements, especially trace-element contaminant surveillance. The first part of this paper presents general information on the mineral composition of infant formula and milk products and their regulatory status. In the second part, a survey describes the main techniques and related current official methods determining minerals and trace elements in infant formula and milk products applied for by various international organizations (AOAC INTERNATIONAL, the International Organization for Standardization, the International Dairy Federation, and the European Committe for Standardization). The third part summarizes method officialization activities by Stakeholder Panels on Infant Formula and Adult Nutritionals and Stakeholder Panel on Strategic Food Analytical Methods. The final part covers a general discussion focusing on analytical gaps and future trends in inorganic analysis that have been applied for in infant formula and milk-based products.

  16. Solid-phase extraction and determination of trace elements in environmental samples using naphthalene adsorbent

    International Nuclear Information System (INIS)

    Pourreza, N.

    2004-01-01

    Naphthalene co-precipitated with quaternary ammonium salt such as tetraoctyl ammonium bromide and methyltrioctyl ammonium chloride have been used as adsorbent for solid phase extraction of metal ions such as Hg, Cd and Fe. The metal ions are retained on the adsorbent in a column as their complexes with suitable ligands and eluted by an eluent before instrumental measurements. The optimization of the procedures for solid phase extraction and consequent determination of trace elements and application to environmental samples especially water samples will be discussed. (author)

  17. Determination of trace metals and analysis of arsenic species in tropical marine fishes from Spratly islands.

    Science.gov (United States)

    Li, Jingxi; Sun, Chengjun; Zheng, Li; Jiang, Fenghua; Wang, Shuai; Zhuang, Zhixia; Wang, Xiaoru

    2017-09-15

    Trace metal contents in 38 species of tropical marine fishes harvested from the Spratly islands of China were determined by microwave digestion and inductively coupled plasma mass spectrometry analysis. Arsenic species were determined by high-performance liquid chromatography and inductively coupled plasma mass spectrometry analysis. The average levels of Al, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, As, Se, Mo, Cd, Pb, and U in the fish samples were 1.683, 0.350, 0.367, 2.954, 36.615, 0.087, 0.319, 1.566, 21.946, 20.845, 2.526, 3.583, 0.225, 0.140, and 0.061mg·kg -1 , respectively; Fe, Zn, and As were found at high concentrations. The trace metals exhibited significant positive correlation between each other, with r value of 0.610-0.852. Further analysis indicated that AsB (8.560-31.020mg·kg -1 ) was the dominant arsenic species in the fish samples and accounted for 31.48% to 47.24% of the total arsenic. As(III) and As(V) were detected at low concentrations, indicating minimal arsenic toxicity. Copyright © 2017. Published by Elsevier Ltd.

  18. Determination of trace elements in seawater by air-flow injection/ICP-MS with chelating resin preconcentration

    International Nuclear Information System (INIS)

    Lee, Kyue-Hyung; Ohshima, Mitsuko; Motomizu, Shoji

    2002-01-01

    Multielement determination of major to trace metals in a deep seawater malt was accomplished by inductively coupled plasma-mass spectrometry (ICP-MS) together with inductively coupled plasma-atomic emission spectrometry (ICP-AES). Major elements, such as Na, K, Mg, and Ca, were measured by ICP-AES and normal continuos nebulization ICP-MS after sample dilution by 10 3 -10 6 fold. Fifteen trace elements in the concentrated metal solutions pretreated with cation-exchange resin or chelating resin could be simultaneously determined by air-flow injection/ICP-mass spectrometry (AFI/ICP-MS). Since the injection volume for AFI/ICP-MS was 25 μl, final samples volumes less than 500 μl were enough for several replicate measurements. Three different preconcentration methods assisted with AFI/ICP-MS were examined and could be successfully applied to a deep seawater malt. The analytical results of rate earth elements (REEs) and Co, Ni, Cu, Zn, Cd, and Pb obtained by AFI/ICP-MS coupled with disk filtration method using iminodiacetate (IDA)-type chelating resin were favorably agreed with the data obtained by AFI/ICP-MS coupled with column preconcentration method using chitosan-based chelating resin. (author)

  19. Coacervative extraction of trace lead from natural waters prior to its determination by electrothermal atomic absorption spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Hagarová, Ingrid, E-mail: hagarova@fns.uniba.sk; Bujdoš, Marek; Matúš, Peter; Kubová, Jana

    2013-10-01

    In this work, a relatively simple and sensitive method for separation/preconcentration of trace lead from natural waters prior to its determination by electrothermal atomic absorption spectrometry has been proposed. The method is based on the extraction of Pb–dithizone chelate with coacervates made up of lauric acid in the presence of potassium ions and methanol. Several important factors affecting extraction efficiency such as pH, concentration of lauric acid and dithizone, ionic strength, incubation and centrifugation time were investigated and optimized. After separation of aqueous bulk solution from surfactant-rich phase, the final extract was redissolved by using 500 μl of methanol acidified with 0.2 mol l{sup −1} HNO{sub 3}. Under the optimized conditions (using initial sample volume of 10 ml), enrichment factor of 17.0, detection limit of 0.12 μg l{sup −1}, quantification limit of 0.38 μg l{sup −1}, relative standard deviation of 4.2% (for 2 μg l{sup −1} of Pb; n = 26), linearity of the calibration graph in the range of 0.5–4.0 μg l{sup −1} (with correlation coefficient better than 0.995) were achieved. The method was validated by the analysis of certified reference material (TMDA-61). Extraction recoveries for the CRM, spiked model solutions and spiked natural water samples were in the range of 91–96%. Finally, the method was applied to the separation/preconcentration and determination of trace lead in natural waters. - Highlights: • The potential of coacervates for the extraction of metal ions is examined. • No difficulties in coupling of ETAAS with the proposed CAE are observed. • Achieved preconcentration factor results in enhanced sensitivity. • Analytical performance is confirmed by the reliable determination of trace Pb. • The proposed CAE is ecofriendly and efficient.

  20. Trace Elements in Human Tooth Enamel

    Energy Technology Data Exchange (ETDEWEB)

    Nixon, G. S. [Turner Dental School, University Of Manchester, Manchester (United Kingdom); Smith, H.; Livingston, H. D. [Department of Forensic Medicine, University Of Glasgow, Glasgow (United Kingdom)

    1967-10-15

    The trace elements are considered to play a role in the resistance of teeth to dental caries. The exact mechanism by which they act has not yet been fully established. Estimations of trace elements have been undertaken in sound human teeth. By means of activation analysis it has been possible to determine trace element concentrations in different layers of enamel in the same tooth. The concentrations of the following elements have been determined: arsenic, antimony, copper, zinc, manganese, mercury, molybdenum and vanadium. The distribution of trace elements in enamel varies from those with a narrow range, such as manganese, to those with a broad range, such as antimony. The elements present in the broad range are considered to be non-essential and their presence is thought to result from a chance incorporation into the enamel. Those in the narrow range appear to be essential trace elements and are present in amounts which do not vary unduly from other body tissues. Only manganese and zinc were found in higher concentrations in the surface layer of enamel compared with the inner layers. The importance of the concentration of trace elements on this surface layer of enamel is emphasized as this layer is the site of the first attack by the carious process. (author)

  1. Determination of Trace and Volatile Element Abundance Systematics of Lunar Pyroclastic Glasses 74220 and 15426 Using LA-ICP-MS

    Science.gov (United States)

    McIntosh, E. Carrie; Porrachia, Magali; McCubbin, Francis M.; Day, James M. D.

    2017-01-01

    Since their recognition as pyroclastic glasses generated by volcanic fire fountaining on the Moon, 74220 and 15426 have garnered significant scientific interest. Early studies recognized that the glasses were particularly enriched in volatile elements on their surfaces. More recently, detailed analyses of the interiors of the glasses, as well as of melt inclusions within olivine grains associated with the 74220 glass beads, have determined high H2O, F, Cl and S contents. Such elevated volatile contents seem at odds with evidence from moderately volatile elements (MVE), such as Zn and K, for a volatile- depleted Moon. In this study, we present initial results from an analytical campaign to study trace element abundances within the pyroclastic glass beads. We report trace element data determined by laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) for 15426 and 74220.

  2. Combination of flame atomic absorption spectrometry with ligandless-dispersive liquid- liquid microextraction for preconcentration and determination of trace amount of lead in water samples

    Directory of Open Access Journals (Sweden)

    Y.M. Baghelani

    2013-05-01

    Full Text Available A new ligandless-dispersive liquid–liquid microextraction method has been developed for the separation and flame atomic absorption spectrometry determination of trace amount of lead(II ion. In the proposed approach 1,2-dicholorobenzene and ethanol were used as extraction and dispersive solvents. Factors influencing the extraction efficiency of lead, including the extraction and dispersive solvent type and volume, pH of sample solution, concentration of chloride and extraction time were studied. Under the optimal conditions, the calibration curve was linear in the range of 7.0–6000 ng mL−1 of lead with R2 = 0.9992 (n = 10 and detection limit based on three times the standard deviation of the blank (3Sb was 0.5 ng mL−1 in original solution. The relative standard deviation for eight replicate determinations of 1.0 mg mL-1 lead was ±1.6%. The high efficiency of dispersive liquid-liquid microextraction to carry out the determination of trace amounts of lead in complex matrices was demonstrated. The proposed method has been applied for determination of trace amounts of lead in water samples and satisfactory results were obtained. The accuracy was checked by analyzing a certified reference material from the National Institute of Standard and Technology, Trace elements in water (NIST CRM 1643e.

  3. Tracing a planar algebraic curve

    International Nuclear Information System (INIS)

    Chen Falai; Kozak, J.

    1994-09-01

    In this paper, an algorithm that determines a real algebraic curve is outlined. Its basic step is to divide the plane into subdomains that include only simple branches of the algebraic curve without singular points. Each of the branches is then stably and efficiently traced in the particular subdomain. Except for the tracing, the algorithm requires only a couple of simple operations on polynomials that can be carried out exactly if the coefficients are rational, and the determination of zeros of several polynomials of one variable. (author). 5 refs, 4 figs

  4. Freeze dried samples of volcanic gases - a new method for the determination of trace elements by NAA

    International Nuclear Information System (INIS)

    Bichler, M.; Sortino, F.

    1997-01-01

    A new routine technique for the determination of trace elements in volcanic gases by NAA is presented. For time and money saving reasons this method is applicable to samples, collected by the conventional method. This technique uses evacuated glass bottles, partly filled with NaOH solution to absorb acidic gas components and CO 2 , which is the main constituent of the incondensable gas fraction at ambient conditions. The application of NAA to samples collected by this method shows two main sources of difficulties: drying of NaOH without loosing volatile elements of interest (in particular Hg and Se) and the high activities of 24 Na after neutron irradiation. The first can be avoided by liquid irradiation, thereby limiting the irradiation time, the second excludes the determination of short and medium lived nuclides because of the high γ-background due to 24 Na. A new freeze drying technique enables the application of long irradiation times and therefore the use of long-lived activation products for analysis. The samples of volcanic gases were collected at the fumarole fields of La Fossa volcano on the island Vulcano. Southern Italy. This technique allows very sensitive determinations of trace elements in volcanic gases and adds highly valuable information to the understanding and modeling of volcanic gas sources. (orig.)

  5. Ultra-trace determination of plutonium in marine samples using multi-collector inductively coupled plasma mass spectrometry.

    Science.gov (United States)

    Lindahl, Patric; Keith-Roach, Miranda; Worsfold, Paul; Choi, Min-Seok; Shin, Hyung-Seon; Lee, Sang-Hoon

    2010-06-25

    Sources of plutonium isotopes to the marine environment are well defined, both spatially and temporally, which makes Pu a potential tracer for oceanic processes. This paper presents the selection, optimisation and validation of a sample preparation method for the ultra-trace determination of Pu isotopes ((240)Pu and (239)Pu) in marine samples by multi-collector (MC) ICP-MS. The method was optimised for the removal of the interference from (238)U and the chemical recovery of Pu. Comparison of various separation strategies using AG1-X8, TEVA, TRU, and UTEVA resins to determine Pu in marine calcium carbonate samples is reported. A combination of anion-exchange (AG1-X8) and extraction chromatography (UTEVA/TRU) was the most suitable, with a radiochemical Pu yield of 87+/-5% and a U decontamination factor of 1.2 x 10(4). Validation of the method was accomplished by determining Pu in various IAEA certified marine reference materials. The estimated MC-ICP-MS instrumental limit of detection for (239)Pu and (240)Pu was 0.02 fg mL(-1), with an absolute limit of quantification of 0.11 fg. The proposed method allows the determination of ultra-trace Pu, at femtogram levels, in small size marine samples (e.g., 0.6-2.0 g coral or 15-20 L seawater). Finally, the analytical method was applied to determining historical records of the Pu signature in coral samples from the tropical Northwest Pacific and (239+240)Pu concentrations and (240)Pu/(239)Pu atom ratios in seawater samples as part of the 2008 GEOTRACES intercalibration exercise. Copyright 2010 Elsevier B.V. All rights reserved.

  6. Ultra-trace determination of plutonium in marine samples using multi-collector inductively coupled plasma mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Lindahl, Patric, E-mail: patriclindahl@yahoo.com [Marine Environment Research Department, Korea Ocean Research and Development Institute, 1270 Sadong, Ansan 426-744 (Korea, Republic of); School of Geography, Earth and Environmental Sciences, University of Plymouth, Drake Circus, Plymouth PL48AA (United Kingdom); Keith-Roach, Miranda; Worsfold, Paul [School of Geography, Earth and Environmental Sciences, University of Plymouth, Drake Circus, Plymouth PL48AA (United Kingdom); Choi, Min-Seok; Shin, Hyung-Seon [Division of Earth and Environmental Science, Korea Basic Science Institute, 113 Gwahangno, Yusung-gu, Daejon 305-333 (Korea, Republic of); Lee, Sang-Hoon [Marine Geology and Geophysics Laboratory, Korea Ocean Research and Development Institute, 1270 Sadong, Ansan 426-744 (Korea, Republic of)

    2010-06-25

    Sources of plutonium isotopes to the marine environment are well defined, both spatially and temporally, which makes Pu a potential tracer for oceanic processes. This paper presents the selection, optimisation and validation of a sample preparation method for the ultra-trace determination of Pu isotopes ({sup 240}Pu and {sup 239}Pu) in marine samples by multi-collector (MC) ICP-MS. The method was optimised for the removal of the interference from {sup 238}U and the chemical recovery of Pu. Comparison of various separation strategies using AG1-X8, TEVA, TRU, and UTEVA resins to determine Pu in marine calcium carbonate samples is reported. A combination of anion-exchange (AG1-X8) and extraction chromatography (UTEVA/TRU) was the most suitable, with a radiochemical Pu yield of 87 {+-} 5% and a U decontamination factor of 1.2 x 10{sup 4}. Validation of the method was accomplished by determining Pu in various IAEA certified marine reference materials. The estimated MC-ICP-MS instrumental limit of detection for {sup 239}Pu and {sup 240}Pu was 0.02 fg mL{sup -1}, with an absolute limit of quantification of 0.11 fg. The proposed method allows the determination of ultra-trace Pu, at femtogram levels, in small size marine samples (e.g., 0.6-2.0 g coral or 15-20 L seawater). Finally, the analytical method was applied to determining historical records of the Pu signature in coral samples from the tropical Northwest Pacific and {sup 239+240}Pu concentrations and {sup 240}Pu/{sup 239}Pu atom ratios in seawater samples as part of the 2008 GEOTRACES intercalibration exercise.

  7. Ultra-trace determination of plutonium in marine samples using multi-collector inductively coupled plasma mass spectrometry

    International Nuclear Information System (INIS)

    Lindahl, Patric; Keith-Roach, Miranda; Worsfold, Paul; Choi, Min-Seok; Shin, Hyung-Seon; Lee, Sang-Hoon

    2010-01-01

    Sources of plutonium isotopes to the marine environment are well defined, both spatially and temporally, which makes Pu a potential tracer for oceanic processes. This paper presents the selection, optimisation and validation of a sample preparation method for the ultra-trace determination of Pu isotopes ( 240 Pu and 239 Pu) in marine samples by multi-collector (MC) ICP-MS. The method was optimised for the removal of the interference from 238 U and the chemical recovery of Pu. Comparison of various separation strategies using AG1-X8, TEVA, TRU, and UTEVA resins to determine Pu in marine calcium carbonate samples is reported. A combination of anion-exchange (AG1-X8) and extraction chromatography (UTEVA/TRU) was the most suitable, with a radiochemical Pu yield of 87 ± 5% and a U decontamination factor of 1.2 x 10 4 . Validation of the method was accomplished by determining Pu in various IAEA certified marine reference materials. The estimated MC-ICP-MS instrumental limit of detection for 239 Pu and 240 Pu was 0.02 fg mL -1 , with an absolute limit of quantification of 0.11 fg. The proposed method allows the determination of ultra-trace Pu, at femtogram levels, in small size marine samples (e.g., 0.6-2.0 g coral or 15-20 L seawater). Finally, the analytical method was applied to determining historical records of the Pu signature in coral samples from the tropical Northwest Pacific and 239+240 Pu concentrations and 240 Pu/ 239 Pu atom ratios in seawater samples as part of the 2008 GEOTRACES intercalibration exercise.

  8. Determination of trace element contents in grass samples for cattle feeding using NAA techniques

    Energy Technology Data Exchange (ETDEWEB)

    Yusof, Alias Mohamad; Jagir Singh, Jasbir Kaur

    1987-09-01

    An investigation on trace elements contents in six types of grass samples used for cattle feeding have been carried out using NAA techniques. The grass samples, Mardi Digit, African Star, Signal, Guinea, Setaria and Setaria Splendida were found to contain at least 19 trace elements in varying concentrations. The results were compared to the figures obtained from available sources to ascertain the status as to whether the grass samples studied would satisfy the minimum requirements of trace elements present in grass for cattle feeding or otherwise. Preference made on the suitability of the grass samples for cattle feeding was based on the availability and abundance of the trace elements, taking into account factors such as the degree of toxicity, inadequate amounts and contamination due to the presence of other trace elements not essential for cattle feeding.

  9. Determination of trace element contents in grass samples for cattle feeding using NAA techniques

    International Nuclear Information System (INIS)

    Alias Mohamad Yusof; Jasbir Kaur Jagir Singh

    1987-01-01

    An investigation on trace elements contents in six types of grass samples used for cattle feeding have been carried out using NAA techniques. The grass samples, Mardi Digit, African Star, Signal, Guinea, Setaria and Setaria Splendida were found to contain at least 19 trace elements in varying concentrations. The results were compared to the figures obtained from available sources to ascertain the status as to whether the grass samples studied would satisfy the minimum requirements of trace elements present in grass for cattle feeding or otherwise. Preference made on the suitability of the grass samples for cattle feeding was based on the availability and abundance of the trace elements, taking into account factors such as the degree of toxicity, inadequate amounts and contamination due to the presence of other trace elements not essential for cattle feeding. (author)

  10. Neurient: An Algorithm for Automatic Tracing of Confluent Neuronal Images to Determine Alignment

    Science.gov (United States)

    Mitchel, J.A.; Martin, I.S.

    2013-01-01

    A goal of neural tissue engineering is the development and evaluation of materials that guide neuronal growth and alignment. However, the methods available to quantitatively evaluate the response of neurons to guidance materials are limited and/or expensive, and may require manual tracing to be performed by the researcher. We have developed an open source, automated Matlab-based algorithm, building on previously published methods, to trace and quantify alignment of fluorescent images of neurons in culture. The algorithm is divided into three phases, including computation of a lookup table which contains directional information for each image, location of a set of seed points which may lie along neurite centerlines, and tracing neurites starting with each seed point and indexing into the lookup table. This method was used to obtain quantitative alignment data for complex images of densely cultured neurons. Complete automation of tracing allows for unsupervised processing of large numbers of images. Following image processing with our algorithm, available metrics to quantify neurite alignment include angular histograms, percent of neurite segments in a given direction, and mean neurite angle. The alignment information obtained from traced images can be used to compare the response of neurons to a range of conditions. This tracing algorithm is freely available to the scientific community under the name Neurient, and its implementation in Matlab allows a wide range of researchers to use a standardized, open source method to quantitatively evaluate the alignment of dense neuronal cultures. PMID:23384629

  11. Determination of trace impurities in iron-based alloy using neutron activation analysis

    International Nuclear Information System (INIS)

    Zaidi, J.H.; Waheed, S.; Ahmad, S.

    2000-01-01

    A radiochemical neutron activation analysis procedure has been developed and applied to investigate 40 major, minor, and trace impurities in iron-based alloy. A comparison of RNAA and INAA indicated a significant improvement in the detection limits. The extensive use of these alloys in the heavy mechanical industry, manufacturing of aircraft engines, nuclear applications, medical devices and chemical equipment requires their precise characterization. The concentration of iron in the iron-based alloy was found to be 86.7%, whereas Ca, Cr, K, Mg, Mn, V and W were the other constituents of the alloy, which constituted to around 12.89%. The rest of the elements were present in minor or trace levels. Most of the rare earth elements were also present in trace amounts. (orig.)

  12. Determination of several trace metals in biological materials by PIXE analysis after solvent extraction and polystyrene-film collection

    International Nuclear Information System (INIS)

    Iwata, Yoshihiro; Korenaga, Tatsumi; Suzuki, Nobuo

    1991-01-01

    Traces of vanadium, manganese, iron, cobalt, nickel, copper, and zinc were quantitatively extracted with diethyldithiocarbamate (DDTC) in benzene from a digested solution of biological materials and the metal-DDTC complexes were collected into a small amount of polystyrene foam produced by lyophilization of the benzene extract after addition of polystyrene. The polystyrene foam was dissolved in benzene and spread on Mylar film. After drying, a polystyrene film containing metal-DDTC complexes was produced on Mylar film, and then the polystyrene film was peeled from the Mylar film. This film was subjected to PIXE analysis. This method was applied to NBS SRM 1572 citrus leaves and a marine macroalgal sample, and 6 trace metals were simultaneously and accurately determined. (author)

  13. Determination of trace elements in wool fibre by instrumental neutron activation analysis and relation between trace element contents and quality of wool

    International Nuclear Information System (INIS)

    Eozyol, H.

    1990-01-01

    Wool samples were analyzed by neutron activation analysis and 17 elements, Al, Ag, Au, As, Br, Ca, Co, Cr, Cu, Fe, La, Mg, Mn, Na, Sb, Se and Zn were measured quantitatively. The presence of seven others, Ce, Eu, I, Mo, Te and W was noted. Since several elements, such as Cd, Hg and Pb could not be conveniently determined by NAA, Atomic Absorption Spectroscopy (AAS) was used instead. Cu and Zn were also analyzed by NAA and AAS to compare these two methods. Mechanical properties of samples were measured and the relations between the trace element contents and properties were investigated. (author) 16 refs.; 7 tabs

  14. The determination of the C, N, O and trace element content of Triticum aestivum by activation analysis, X-ray excitation and mass spectrometry

    International Nuclear Information System (INIS)

    Leonhardt, J.W.; Dahn, E.; Dietze, H.J.; Freyer, K.; Geisler, M.; Hartmann, G.; Jung, K.; Schelhorn, H.

    1979-01-01

    The results of determinations of the C, N, O and trace element content of grains, sprouts and leaves of Triticum aestivum by means of various methods of activation analysis, X-ray excitation and mass spectrometry are presented. The C and O contents were determined by X-ray excitation; the O, N, P and Si contents were measured by NAA with 14-MeV neutrons, and the trace elements were determined by NAA with thermal neutrons. A mass-spectrometric survey analysis confirmed the results obtained by NAA. The use of neutron-induced nuclear reactions together with autoradiography enabled a representative picture to be formed of the spatial distribution in two dimensions of 14 N in biological specimens. (author)

  15. Epidemic contact tracing via communication traces.

    Directory of Open Access Journals (Sweden)

    Katayoun Farrahi

    Full Text Available Traditional contact tracing relies on knowledge of the interpersonal network of physical interactions, where contagious outbreaks propagate. However, due to privacy constraints and noisy data assimilation, this network is generally difficult to reconstruct accurately. Communication traces obtained by mobile phones are known to be good proxies for the physical interaction network, and they may provide a valuable tool for contact tracing. Motivated by this assumption, we propose a model for contact tracing, where an infection is spreading in the physical interpersonal network, which can never be fully recovered; and contact tracing is occurring in a communication network which acts as a proxy for the first. We apply this dual model to a dataset covering 72 students over a 9 month period, for which both the physical interactions as well as the mobile communication traces are known. Our results suggest that a wide range of contact tracing strategies may significantly reduce the final size of the epidemic, by mainly affecting its peak of incidence. However, we find that for low overlap between the face-to-face and communication interaction network, contact tracing is only efficient at the beginning of the outbreak, due to rapidly increasing costs as the epidemic evolves. Overall, contact tracing via mobile phone communication traces may be a viable option to arrest contagious outbreaks.

  16. Epidemic contact tracing via communication traces.

    Science.gov (United States)

    Farrahi, Katayoun; Emonet, Rémi; Cebrian, Manuel

    2014-01-01

    Traditional contact tracing relies on knowledge of the interpersonal network of physical interactions, where contagious outbreaks propagate. However, due to privacy constraints and noisy data assimilation, this network is generally difficult to reconstruct accurately. Communication traces obtained by mobile phones are known to be good proxies for the physical interaction network, and they may provide a valuable tool for contact tracing. Motivated by this assumption, we propose a model for contact tracing, where an infection is spreading in the physical interpersonal network, which can never be fully recovered; and contact tracing is occurring in a communication network which acts as a proxy for the first. We apply this dual model to a dataset covering 72 students over a 9 month period, for which both the physical interactions as well as the mobile communication traces are known. Our results suggest that a wide range of contact tracing strategies may significantly reduce the final size of the epidemic, by mainly affecting its peak of incidence. However, we find that for low overlap between the face-to-face and communication interaction network, contact tracing is only efficient at the beginning of the outbreak, due to rapidly increasing costs as the epidemic evolves. Overall, contact tracing via mobile phone communication traces may be a viable option to arrest contagious outbreaks.

  17. Trace element deficiency and its diagnosis by radioisotope injection

    International Nuclear Information System (INIS)

    Kirchgessner, M.; Schwarz, F.J.

    1976-01-01

    The metabolism of trace elements is subject to certain mechanisms of homeostatic regulation. The supply status of the trace elements, iron, copper, zinc and manganese has definite effects on their respective extent of intestinal absorption, retention and intestinal excretion. Experimental studies show that there is an increase in intestinal absorption and retention, and a decrease in turnover rate and endogenous excretion of these trace elements in response to deficient dietary intake. On the basis of these results, three models are discussed for the use of radioisotopes in the diagnosis of situations of trace element deficiency: (1) Determination of the intestinal absorption of an orally administered radioisotope dose by measuring the activity of blood; (2) Determination of the retention of a parenterally administered dose in blood or plasma; and (3) Determination of the endogenous faecal excretion of a parenterally administered dose. The advantages and disadvantages of these models are discussed. Determination of the endogenous secretion of the trace element after intravenous injection of its radioisotope may be considered as the simplest and most informative method. (author)

  18. Determination of trace levels of iodine in table salt by ICP-TOF MS

    International Nuclear Information System (INIS)

    Waqar, F.; Muhammad, B.; Hakim, M.; Jan, S.

    2012-01-01

    An ion exchange method was established for the effective removal of sodium matrix for iodine determination by ICP-TOF-MS technique. Since the direct determination of trace level analytes in the presence of heavy matrix is not recommended by this technique. Therefore, the removal of matrix is essentially required to achieve better detection limits and to avoid memory effects. The extraction system was designed for the removal of matrix prior to the analysis by ICP-MS, various parameters were optimized to achieve efficient removal of matrix. The accuracy of the method was evaluated by spiking salt samples with known amount of iodine (50 mu g/g) and % recoveries were calculated. The recoveries obtained were > 98% with relative standard deviation (RSD) < 5%. The established method was applied for the analysis of commercially available iodized table salt samples. The results and % recoveries are given. The most commonly used iodo metric titration method is not satisfactory as it has 5-10 % quantitative error. Our method is reliable and could be conveniently applied for the determination of iodine in table salt samples. (Orig./A.B.)

  19. Trace water vapor determination in nitrogen and corrosive gases using infrared spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Espinoza, L.H.; Niemczyk, T.M. [Univ. of New Mexico, Albuquerque, NM (United States). Dept. of Chemistry; Stallard, B.R.; Garcia, M.J. [Sandia National Labs., Albuquerque, NM (United States)

    1997-06-01

    The generation of particles in gas handling systems as a result of corrosion is a major concern in the microelectronics industry. The corrosion can be caused by the presence of trace quantities of water in corrosive gases such as HCl or HBr. FTIR spectroscopy has been shown to be a method that can be made compatible with corrosive gases and is capable of detecting low ppb levels of water vapor. In this report, the application of FTIR spectroscopy combined with classical least squares multivariate calibration to detect trace H{sub 2}O in N{sub 2}, HCl and HBr is discussed. Chapter 2 discusses the gas handling system and instrumentation required to handle corrosive gases. A method of generating a background spectrum useful to the measurements discussed in this report, as well as in other application areas such as gas phase environmental monitoring, is discussed in Chapter 3. Experimental results obtained with the first system are presented in Chapter 4. Those results made it possible to optimize the design options for the construction of a dedicate system for low ppb water vapor determination. These designs options are discussed in Chapter 5. An FTIR prototype accessory was built. In addition, a commercially available evacuable FTIR system was obtained for evaluation. Test results obtained with both systems are discussed in Chapter 6. Experiments dealing with the interaction between H{sub 2}O-HCl and potential improvements to the detection system are discussed in Chapter 7.

  20. Determination of trace elements in tailpipe fish produced in artificial farms and from white and blue nile

    International Nuclear Information System (INIS)

    Ahmed, Zeinb Khalil Elsaim

    2017-01-01

    In this study, an analytical protocol of x-ray fluorescence spectroscopy was used to determine the concentration of 13 trace elements, potassium (K), antimony (Sb), iron (Fe), copper (Cu), zinc (Zn), lead (Pb), bromine (Br), rubidium (Rb), strontium (Sr), mercury (Hg), chromium (Cu), manjense (Mn), and calcium (Ca), in tilapa fish. A total of 70 samples covering 35 fish samples collected from different states includes Eldamazine for blue nile samples and the Mawrada market for the white nile samples and 5 artificial fish farms samples were collected from Om badda in Omdurman and Bahry state for three farms Alsamraband Aldorshab and from Alshagra state in Khartoum, during may to June 2016. The trace elements detected in all samples, and the concentration in part million (ppm). The concentrations of trace elements followed the sequence of, K, Ca, Fe, Zn, Cu, Sr, Rb, Pb, but Cr, Hg and Ni were observed in one fish fram (farm A). The analysis included two tissues (flesh and gills), because most people in Sudan consume the flesh and gills, specially in the small fishes, consider as good indicators for the trace elements, and toxic compounds in general. The analysis indicated that the white nile fishes have higher l eves of most of the trace elements compared to the blue nile, e.g. Fe (560±186) in the white nile, whereas in the blue nile, (188±63). On the other hand , the artificial tilapia farms showed significant variations in the trace elements concentrations. The analysis revealed that a higher concentrations of most of the trace elements in gill tissues than flesh, e.g. Fe (1673±1453) in the flesh, and (9768±1175) in the gills. These results indicated that the gill accumulated higher levels of heavy metals than other organs, because they acted as a depot tissue. In addition, the post hoc test was performed following (Dunnett tests), using the blue nile group as a control group, since it has the lowest trace elements concentrations, among the river nile fishes in

  1. Determination of ultra trace arsenic species in water samples by hydride generation atomic absorption spectrometry after cloud point extraction

    Energy Technology Data Exchange (ETDEWEB)

    Ulusoy, Halil Ibrahim, E-mail: hiulusoy@yahoo.com [University of Cumhuriyet, Faculty of Science, Department of Chemistry, TR-58140, Sivas (Turkey); Akcay, Mehmet; Ulusoy, Songuel; Guerkan, Ramazan [University of Cumhuriyet, Faculty of Science, Department of Chemistry, TR-58140, Sivas (Turkey)

    2011-10-10

    Graphical abstract: The possible complex formation mechanism for ultra-trace As determination. Highlights: {yields} CPE/HGAAS system for arsenic determination and speciation in real samples has been applied first time until now. {yields} The proposed method has the lowest detection limit when compared with those of similar CPE studies present in literature. {yields} The linear range of the method is highly wide and suitable for its application to real samples. - Abstract: Cloud point extraction (CPE) methodology has successfully been employed for the preconcentration of ultra-trace arsenic species in aqueous samples prior to hydride generation atomic absorption spectrometry (HGAAS). As(III) has formed an ion-pairing complex with Pyronine B in presence of sodium dodecyl sulfate (SDS) at pH 10.0 and extracted into the non-ionic surfactant, polyethylene glycol tert-octylphenyl ether (Triton X-114). After phase separation, the surfactant-rich phase was diluted with 2 mL of 1 M HCl and 0.5 mL of 3.0% (w/v) Antifoam A. Under the optimized conditions, a preconcentration factor of 60 and a detection limit of 0.008 {mu}g L{sup -1} with a correlation coefficient of 0.9918 was obtained with a calibration curve in the range of 0.03-4.00 {mu}g L{sup -1}. The proposed preconcentration procedure was successfully applied to the determination of As(III) ions in certified standard water samples (TMDA-53.3 and NIST 1643e, a low level fortified standard for trace elements) and some real samples including natural drinking water and tap water samples.

  2. Internal standard method for determination of gallium and some trace elements in bauxite by neutron activation analysis

    International Nuclear Information System (INIS)

    Chen, S.G.; Tsai, H.T.

    1983-01-01

    A method is described for the determination of gallium and other trace elements such as Ce, Cr, Hf, Lu and Th in bauxite by the technique of neutron activation analysis using gold as internal standard. Isopropyl ether was used as organic extractant radioactive gallium from the sample. This method yields very good accuracy with a relative error of +-3%. (author)

  3. Substoichiometric neutron activation determination of gold

    International Nuclear Information System (INIS)

    Mitchell, J.W.; Riley, J.E. Jr.; Payne, V.

    1978-01-01

    A highly precise and selective method is described for the determination of traces of gold by substoichiometric extraction from hydrochloric acid with tri-n-octylphosphine sulfide in cyclohexane following thermal neutron activation. Fundamental aspects of the extraction system are discussed and results are reported for the determination of gold in an effluent from a recovery process containing a complexed species of gold and unknown amounts of cyanide, citrate, phosphate, potassium and sodium. Other constituents of the effluent stream include traces of the transition elements Co, Ni, Fe, Cu, Zn, Pb and Sn at concentrations less than 50 ppm. One hour was allowed for the Au 3+ carrier and the 198 Au complexed species in samples and standards to oxidize, exchange, and reach chemical equilibrium. Samples were then equilibrated by shaking with the organic phase for thirty min. The percentage extractions (%E) for the substoichiometric separation of gold from the effluent and from the corresponding comparison standards were monitored. The mean percentage extractions for the substoichiometric separations of carrier from the effluent, and its corresponding standard were 75.3 and 59.3, respectively. These data are estimated to be accurate within +-2.0%. (T.G.)

  4. Determination of Trace Antimony (III by Adsorption Voltammetry at Carbon Paste Electrode

    Directory of Open Access Journals (Sweden)

    Nongyue He

    2005-05-01

    Full Text Available This work presents a sensitive method for the determination of trace antimonybased on the antimony-pyrogallol red (PGR adsorption at a carbon paste electrode (CPE.The optimal conditions were to use an electrode containing 25% paraffin oil and 75%high purity graphite powder as working electrode, a 0.10 mol/L HCl solution containing3.0×10-5 mol/L PGR as accumulation medium and a 0.20 mol/L HCl solution aselectrolyte with an accumulation time of 150 s and a reduction time of 60 s at -0.50 Vfollowed with a sweep from -0.50 V to 0.20 V. The mechanism of the electrode reactionwas discussed. Interferences of other metal ions were studied as well. The detection limitwas 1×10-9 mol/L. The linear range was from 2.0×10-9 mol/L to 5.0×10-7 mol/L.Application of the proposed method to the determination of antimony in water andhuman hair samples gave good results.

  5. Studies of trace element determinations in nails by neutron activation analysis method

    International Nuclear Information System (INIS)

    Aguiar, Amilton Reinaldo; Saiki, Mitiko

    1996-01-01

    The purpose of this work was to develop the neutron activation analysis for trace element determinations in nails in order to apply this method to the study of the cystic fibrosis disease. It was verified that the elements Al, As, Br, Ca, Cd, Cl, Co, Cr, Cu, Fe, K, Mg, Mn, Na, Se and Zn can be determined by using short and long irradiations with thermal neutron flux from 10 11 to 10 13 n.cm -2 . -1 at the IEA-R1 nuclear research reactor. The washing solutions of triton-X100, NH 4 OH and acetone were tested in order to eliminate external contaminants from the nail samples. The nail analyses of the individual fingers from both of hands showed that the samples must be collected from all the fingers from both of hands to have a representative sample. The precision and the accuracy of the results were also examined by analyzing NIES 10C Rice Flour, IUPAC Bowen's Kale and NIST 1572 Citrus Leaves reference materials. (author)

  6. INAA for the determination of trace elements and evaluation of their enrichment factors in lichens of high altitude areas

    International Nuclear Information System (INIS)

    Bergamaschi, L.; Rizzio, E.; Giaveri, G.; Profumo, A.; Gallorini, M.; Giordani, L.

    2005-01-01

    Trace element (TE) characterization and analysis in epiphytic lichens collected in different areas of the Himalayas (Nepal) and of the Alps (Italy) is presented. The results give information for the assessment of TE distribution present in the two different areas. The evaluation of the enrichment factors may provide information for many elements about their association to long-distance atmospheric transport phenomena. To this purpose, samples of superficial soils, collected in the same areas of those of the lichens, have also been analyzed. Most of the trace elements were determined by instrumental neutron activation analysis (INAA), while lead and cadmium measurements were carried out with electrothermal atomic absorption spectroscopy (ET-AAS). (author)

  7. Survey of currently available reference materials for use in connection with the determination of trace elements in biological materials

    International Nuclear Information System (INIS)

    Parr, R.M.

    1983-09-01

    Elemental analysis of biological materials is at present the subject of intensive study by many different research groups throughout the world, in view of the importance of these trace elements in health and medical diagnosis. IAEA and other organizations are now making a variety of suitable reference materials available for use in connection with the determination of trace elements in biological materials. To help analysts in making a selection from among these various materials, the present report provides a brief survey of data for all such biological reference materials known to the author. These data are compiled by the author from January 1982 to June 1983

  8. Report on the intercomparison runs for the determination of trace and minor elements in cabbage material. IAEA-359

    International Nuclear Information System (INIS)

    Campbell, M.J.; Radecki, Z.; Trinkl, A.; Burns, K.I.

    2000-04-01

    In 1989, the IAEA decided to produce a cabbage plant reference material that could be characterised for certain agrochemical residues. The cabbage plants (Brassica oleracea var. Sabauda) were grown from seed in Seibersdorf, Austria. The plants were treated with ten different agrochemical products during their growing period. Subsequently, it was decided that the material would also be valuable as a reference material for trace element analysis and quality control purposes. The property values for the trace metal content of the cabbage material, designated IAEA 359, were to be ascribed on the basis of information received from international intercomparison exercises. In parallel, it was decided to despatch the material as part of a joint IAEA-NIST (National Institute of Standards and Technology, USA) project to certify the trace and minor element contents of a spinach reference material (NIST 1570a), in which it was to serve as a quality control material. A similar rationale was used to justify inclusion of IAEA 359 in a small scale exercise for a preliminary characterisation of another IAEA reference material, IAEA 336 Lichen. Between 1992 and 1993, the material was used in 4 projects (2 large scale and 2 smaller scale) where its trace element contents were determined. This report deals with the statistical evaluation of the pooled analytical data from these exercises

  9. Accurate determination of ultra-trace levels of Ti in blood serum using ICP-MS/MS

    International Nuclear Information System (INIS)

    Balcaen, Lieve; Bolea-Fernandez, Eduardo; Resano, Martín; Vanhaecke, Frank

    2014-01-01

    Graphical abstract: -- Highlights: •Novel method for determination of Ti at ultra-trace levels in clinical samples (serum). •Novel method based on Ti(NH 3 ) 6 + reaction product ion formation and double mass selection using recently introduced ICP-QQQ instrumentation. •Lowest limits of detection ever obtained using quadrupole-based instrumentation for Ti. •Accurate determination of basal levels of Ti in blood serum. -- Abstract: Ti is frequently used in implants and prostheses and it has been shown before that the presence of these in the human body can lead to elevated Ti concentrations in body fluids such as serum and urine. As identification of the exact mechanisms responsible for this increase in Ti concentrations, and the risks associated with it, are not fully understood, it is important to have sound analytical methods that enable straightforward quantification of Ti levels in body fluids (for both implanted and non-implanted individuals). Until now, only double-focusing sector field ICP-mass spectrometry (SF-ICP-MS) offered limits of detection that are good enough to deal with the very low basal levels of Ti in human serum. This work reports on the development of a novel method for the accurate and precise determination of trace levels of Ti in human serum samples, based on the use of ICP-MS/MS. O 2 and NH 3 /He have been compared as reaction gases. While the use of O 2 did not enable to overcome all spectral interferences, it has been shown that conversion of Ti + ions into Ti(NH 3 ) 6 + cluster ions by using NH 3 /He as a reaction gas in an ICP-QQQ-MS system, operated in MS/MS mode, provided interference-free conditions and sufficiently low limits of detection, down to 3 ng L −1 (instrumental detection limit obtained for the most abundant Ti isotope). The accuracy of the method proposed was evaluated by analysis of a Seronorm Trace Elements Serum L-1 reference material and by comparing the results obtained with those achieved by means of SF

  10. Trace elements in several species of crustaceans of Amami Island Group in Japan determined by activation analysis

    International Nuclear Information System (INIS)

    Fukushima, M.; Tamate, H.; Nakano, Y.

    2001-01-01

    Concentration levels of trace elements were determined in several species of subtropical crustaceans from Amami Islands in Japan in order to evaluate the levels of specific accumulation of elements among species. Tissue samples prepared from gill, muscle, hepatopancreas, and testis were irradiated for photon activation analysis (PAA) and neutron activation analysis (NAA). By PAA and NAA, eighteen elements could be determined. The levels of Br and I were extremely high in gills of spiny lobster and shovel-nosed lobster, respectively. A high concentration of Ag was found in the hepatopancreas of spiny lobsters collected from the Amami Island, while this element was not detected in the same species collected from Toba. The results suggest that the distribution of the trace elements in different tissues and species varies according to both species and environmental differences. To study the molecular forms of the elements in tissue, fractions that contained protein-bound elements from the hepatopancreas of spiny lobsters were separated by ultracentrifugation and gel filtration chromatography. Elution profiles of the chromatography suggest that Cu, Fe, and Se were bound to proteins, while Ag was not. (author)

  11. An ICP-AES method for the determination of trace metals in uranium by solvent extraction using KSM-17

    International Nuclear Information System (INIS)

    Jacob, Mary; Radhakrishnan, K.; Dhami, P.S.; Kulkarni, V.T.; Joshi, M.V.; Patwardhan, A.B.; Ramanujam, A.; Mathur, J.N.

    1994-01-01

    This paper describes the studies carried out for the determination of trace metallic impurities in uranium solutions. Uranium matrix is separated from the impurity elements by its selective extraction using 2-ethylhexyl hydrogen 2-ethylhexyl phosphonate (KSM-17, equivalent to PC88A). The aqueous phase is analysed for trace impurities by inductively coupled argon plasma atomic emission spectrometry. The studies also include recovery of impurities at various acidities and spectral interferences of uranium over the analyte element channels. Based on the above studies, a method has been standardised for the analysis of nineteen elements in uranium solutions. The relative standard deviation of the method for various elements is in the range of +- 1-5%. (author). 7 refs., 8 tabs., 1 fig

  12. DETERMINATION of the TRACE ELEMENT LEVELS in HAIR of SMOKERS and NON-SMOKERS by ICP-MS

    Directory of Open Access Journals (Sweden)

    Elif Varhan Oral

    2016-09-01

    Full Text Available For at least 50 years, determination of the trace element levels in human hair has been used to assess environmental and vocational exposure to toxic elements . As compared to other biological matrices (e.g. blood, urine, human hair is stable and therefore useful as a matrice. In this study, analyses of toxic and essential trace elements, such as Cd, Pb, Cu and Fe, were done in hair samples which we collected from male smokers (10 people and non-smokers (10 people who live in Diyarbakır, Turkey and concentrations in hair samples were compared. Hair samples were washed by a standard procedure proposed by the International Atomic Energy Agency. Then the samples were dried for 16 h at 110°C in an oven. Solubilization procedure was carried out by nitric acid hydrogen peroxide mixture (3:1 in closed vessels in a microwave oven. Trace element analyses were carried out by using inductively coupled plasma-mass spectrometry (ICP-MS  technique. In our study, while concentrations of Cd, Pb, and Fe elements were found to be considerably higher in smokers than non-smokers, similar results were observed in Cu concentrations. The precision and accuracy of the method was evaluated by applying spike method to samples. Analytical recovery results were found between 91.2% and 104.6%.

  13. Determination of some toxic trace elements in Indian tobacco and its smoke

    International Nuclear Information System (INIS)

    Shaikh, A.N.; Khandekar, R.N.; Anand, S.J.S.; Mishra, U.C.

    1992-01-01

    Toxic trace metals like mercury, arsenic and cadmium have been determined in widely used Indian chewing tobacco and cigarette tobacco by neutron activation followed by sequential radiochemical separation (RNAA). Differential Pulse Anodic Stripping Voltammetry (DPASV) has been used for the estimation of lead, cadmium and copper in cigarette tobacco and its smoke aerosols. The reliability of the data has been assured by analyzing standard reference materials, bovine liver (NBS-1577) and orchard leaves (NBS-1571), and intercomparison of the Pb, Cd and Cu values by three techniques, namely, RNAA, DPASV and Energy Dispersive X-ray Fluorescence technique (EDXRF). The levels of Hg, Cd, As, Pb, and Cu in cigarette and chewing tobacco and the estimated intake of Cd, Cu and Pb to the smoker are presented and discussed. (author) 12 refs.; 3 tabs

  14. Determination of trace elements and heavy metals in sediment using x-ray fluorescence

    International Nuclear Information System (INIS)

    Sidahmed, Muataz Ahmed Ibrahem

    2014-01-01

    In this study, 30 sediment samples were taken randomly from the area of Suba south of Khartoum state. Trace elements and heavy metal were determined in sediments samples using x-ray fluoresce spectroscopy (X RF). K, Ca, Ti, Mn, Fe, Cu, Zn, Pb, Rb, Sr, and Zr were determined by X RF. Standard Reference Material (SRM) from international Atomic Energy Agency (IAEA-Soil-7) has been used to achieve accuracy of X RF method. Measured values were found in agreements with certified values. The average elemental concentrations of K, Ca, Ti, Mn, Fe, Cu, Zn, Pb, Rb, Sr, and Zr were 5882.7, 20703.3, 6264.3, 460.97, 26713.3, 7.7, 43.4, 18.6, 28.6, 144.8, and 173.06, respectively. Correlation between elements was performed also cluster analysis was used to check the similarly between the samples result. The result of study were compared with previous studies and the concentrations of some elements found to be similar.(Author)

  15. Intercomparison and determination of trace elements in urban dust by neutron activation analysis

    International Nuclear Information System (INIS)

    Chung, Yong Sam; Moon, Jong Hwa; Kim, Sun Ha; Park, Kwang Won; Kang, Sang Hun

    2000-01-01

    Trace elements in air samples artificially loaded on filters with urban dust and the bulk material of urban dust as an environmental sample were determined non-destructively using instrumental neutron activation analysis. Standard reference material (Urban Dust, SRM 1648) of the National Institute of Standard and Technology was used for the analytical quality control. The relative error for 37 elements was less than 15% and the standard deviation was less than 10%. 29 elements in the urban dust and 21 elements in the loaded filter sample were determined respectively. To evaluate the proficiency and reliability of the measurement, data intercomparison was performed and 39 analytical laboratories participated in the analysis using different analytical methods; neutron activation analysis, particle induced X-ray emission analysis, X-ray fluorescence analysis and atomic absorption spectrometry. Z-scores were calculated using the standard deviation of the laboratory's mean as target standard deviation, and a good result was obtained that the values fall between-1 and +1 except some elements. (author)

  16. Derivative spectrophotometric determination of trace amounts of Tungsten(VI) in real water samples

    International Nuclear Information System (INIS)

    Viswanatha, C.; Ramakrishna Reddy, K.; Devanna, N.; Praveen Kumar, M.D.

    2012-01-01

    2,4-Dimethoxybenzaldehydeisonicotinoylhydrazone (DMBHIH) has been synthesized and characterized with IR, NMR and Mass Spectroscopic methods. A simple and derivative spectrophotometric method has been developed for the determination of trace amounts of W(VI). The reagent forms a yellow coloured water soluble complex with W(VI) in basic medium (pH 8.0). The molar absorptivity and Sandell's sensitivity of coloured species are 3.43 x 10 4 L.mol -1 cm -1 and 0.0049 μg/cm 2 respectively. Beer's law is obeyed in the range 0.4113-6.2138 μg/ml of W(VI) at λ max 394 nm. W(VI) forms 1:1 complex with DMBHIH and stability constant of the complex was 5.22x10 6 . The first and second derivative amplitude was measured at 453 nm and 468 nm. The developed method applied for the determination of W(VI) in alloys and biological samples. (author)

  17. Application of the radioreagent method to the determination of trace quantities of lead

    International Nuclear Information System (INIS)

    Figueiredo, A.M.G.; Saiki, M.; Lima, F.W. de

    1983-01-01

    The radioreagent method of analysis was applied to determine trace quantities of lead in several types of samples. This method is based on the extraction of radioactive cobalt, displaced by lead from the cobalt chelate of ethylenediaminetetraacetate labeled with 60 Co, into a tetracycline-benzyl alcohol solution. The radioactivity of the released cobalt, extracted into the organic phase, measured by menas of a single channel gamma-ray analyzer coupled to a Na(T1) scintillation detector, is proportional to the lead concentration. The elements which might interfere with the analysis were removed by a chemical separation procedure of lead using dithizone. The method was applied for lead determination in air samples, gasoline and samples from the International Atomic Energy Agency, namely: simulated air filter (Air-3), fresh water (W-3), dried animal whole blood(A-2) and calcinated animal bone (A3/1). The sensitivity, accuracy and precision of the method were also discussed. (Author) [pt

  18. Determination of ultra-trace aluminum in human albumin by cloud point extraction and graphite furnace atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Sun Mei; Wu Qianghua

    2010-01-01

    A cloud point extraction (CPE) method for the preconcentration of ultra-trace aluminum in human albumin prior to its determination by graphite furnace atomic absorption spectrometry (GFAAS) had been developed in this paper. The CPE method was based on the complex of Al(III) with 1-(2-pyridylazo)-2-naphthol (PAN) and Triton X-114 was used as non-ionic surfactant. The main factors affecting cloud point extraction efficiency, such as pH of solution, concentration and kind of complexing agent, concentration of non-ionic surfactant, equilibration temperature and time, were investigated in detail. An enrichment factor of 34.8 was obtained for the preconcentration of Al(III) with 10 mL solution. Under the optimal conditions, the detection limit of Al(III) was 0.06 ng mL -1 . The relative standard deviation (n = 7) of sample was 3.6%, values of recovery of aluminum were changed from 92.3% to 94.7% for three samples. This method is simple, accurate, sensitive and can be applied to the determination of ultra-trace aluminum in human albumin.

  19. Determination of ultra-trace aluminum in human albumin by cloud point extraction and graphite furnace atomic absorption spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Sun Mei, E-mail: sunmei@ustc.edu.cn [Hefei National Laboratory for Physical Sciences on Microscale, University of Science and Technology of China, No. 96, Jinzhai Road, Hefei 230026 (China); Wu Qianghua [Department of Polymer Science and Engineering, University of Science and Technology of China, Hefei 230026 (China)

    2010-04-15

    A cloud point extraction (CPE) method for the preconcentration of ultra-trace aluminum in human albumin prior to its determination by graphite furnace atomic absorption spectrometry (GFAAS) had been developed in this paper. The CPE method was based on the complex of Al(III) with 1-(2-pyridylazo)-2-naphthol (PAN) and Triton X-114 was used as non-ionic surfactant. The main factors affecting cloud point extraction efficiency, such as pH of solution, concentration and kind of complexing agent, concentration of non-ionic surfactant, equilibration temperature and time, were investigated in detail. An enrichment factor of 34.8 was obtained for the preconcentration of Al(III) with 10 mL solution. Under the optimal conditions, the detection limit of Al(III) was 0.06 ng mL{sup -1}. The relative standard deviation (n = 7) of sample was 3.6%, values of recovery of aluminum were changed from 92.3% to 94.7% for three samples. This method is simple, accurate, sensitive and can be applied to the determination of ultra-trace aluminum in human albumin.

  20. [Fluorescence Determination of Trace Se with the Hydride-K13-Rhodamine 6G System].

    Science.gov (United States)

    Liang, Ai-hui; Li, Yuan; Huang, Shan-shan; Luo, Yang-he; Wen, Gui-qing; Jiang, Zhi-liang

    2015-05-01

    Se is a necessary trace element for human and animals, but the excess intake of Se caused poison. Thus, it is very important to determination of Se in foods and water. The target of this study is development of a new, sensitive and selective hydride generation-molecular fluorescence method for the determination of Se. In 0. 36 mol . L-1 sulfuric acid, NaBH4 as reducing agent, Se (IV) is reduced to H2 Se. Usin3-g I solution as absorption liquid3, I- is reduced to I- by H2Se. When adding rhodamine 6G, Rhodamine 6G and I3- form association particles, which lead to the fluorescence intensity decreased. When Se(IV) existing, Rhodamine 6G and I3- bind less, And the remaining amount of Rhodamine 6G increase. So the fluorescence intensity is enhanced. The analytical conditions were optimized, a 0. 36 ml . L-1 H2SO4, 21. 6.g . L-1 NaBH4, 23.3 µm . L-1 rhodamine 6G, and 50 µmol . L-1 KI3 were chosen for use. When the excitation wavelength is at 480nm, the Rayleigh scattering peak does not affect the fluorescence recording, and was selected for determination of Se. Under the selected conditions, Se(IV) concentration in the 0. 02~0. 60 µg . mL-1 range and the increase value of the fluorescence intensity (ΔF) at 562 nm linear relationship. The linear regression equation is ΔF562 nm =12. 6c + 20. 9. The detecton limit was 0.01 µ.g . L-1. The influence of coexistence substances on the hydride generatin-molecular fluorescence determination of 5. 07 X10(-6) mol . L-1 Se(IV) was considered in details. Results showed that this new fluorescence method is of high selectivity, that is, 0. 5 mmol. L-1 Ba2+, Ca2+, Zn2+ and Fe3+, 0. 25 mmol . L-1 . Mg2+, 0. 05 mmol . L-1 K+, 0. 2 mmol . L-1 Al3+, 0. 025 mmol . L-1 Te(VI) do not interfere with the determination. The influence of Hg2+, CD2+ and Cu2+ that precipitate with Se(IV), can be eliminated by addition of complex reagent. This hydride generation-molecular fluorescence method has been applied to determination of trace Se in water

  1. Determination of 25 trace impurity elements in U3O8 by horizontal ICP-AES after separation with TBP levextrel resin chromatography

    International Nuclear Information System (INIS)

    Guan Jingsu; Shi Youqing; Gao Binghua; Liu Yingmei

    1988-01-01

    A method for the determination of Al, As, Ba, Be, Bi, Ca, Cd, Cu, Co, Cr, Fe, Mg, Mn, Mo, Ni, P, Pb, Ru, Sb, Sn, Sr, Ti, V, W and Zn 25 trace elements in U 3 O 8 is reported. The sample is dissolved in HNO 3 or HNO 3 -HCLO 4 -HF and the uranium is separated by TBP Levextrel resin chromatogyaphy. The impurity elements containing in the aquaous phase are determined by horizontal ICp-AES method. With a sample of 300 mg, the detection limit for all the 25 elements is in the range of 0.01∼5ppm, the recovery is in the range of 82∼ 121%, the determination precision (RSD) is less than ±13%. 18 trace elements in reference material of U 3 O 8 prepared in China are determined, the values obtained well with the values of overall median of accepted laboratory means

  2. Trace element analysis of soy sauce

    International Nuclear Information System (INIS)

    Tomita, Michio; Haruyama, Yoichi; Saito, Manabu

    1994-01-01

    Trace elements in soy sauce have been measured by means of in-air PIXE. Six kinds of trace elements were detected, such as Mu, Fe, Ni, Zn, Cu and Br. Concentrations of Mn, Fe, Zn and Br which were observed in all samples, have been determined. Each analyzed sample contained considerable amount of bromine about 160 ppm. (author)

  3. Determination of trace amounts of selenium in minerals and rocks by flame less atomic-absorption spectrometry

    International Nuclear Information System (INIS)

    Alduan, F. A.; Capdevilla, C.

    1980-01-01

    The determination of trace amounts of selenium In silicate rocks and feldspar by solvent extraction and graphite furnace atomic-absorption spectrometry has been stu- died. Sodium diethyl-ditio carbamate and ammonium pyrrolidine dithiocarbamate have been tried as chelating agents. The best results are achieved when selenium is extracted Into carbon tetrachloride as the sodium diethyldithiocarbamate complex. The method allows to detect 0,75 ppm of selenium in the sample. Recoveries are about 100%. (Author) 7 refs

  4. Determination of five trace elements in leaves in Nanfang sweet orange by flame atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Li Fangqing

    2006-01-01

    The five trace elements of copper, zinc, manganese, iron and cobalt in leaves of Nanfang sweet orange are determined by flame atomic absorption spectrometry. The technique is simple, precise and sensitive. The effect of the type of digesting solution (mixed acid), the ratio of mixed acid, the volume of digesting solution and the time of digesting are investigated in details. The results show that leaves of Nanfang sweet orange contain higher amount of iron and zinc. (authors)

  5. Accuracy of trace element determinations in alternate fuels

    Science.gov (United States)

    Greenbauer-Seng, L. A.

    1980-01-01

    A review of the techniques used at Lewis Research Center (LeRC) in trace metals analysis is presented, including the results of Atomic Absorption Spectrometry and DC Arc Emission Spectrometry of blank levels and recovery experiments for several metals. The design of an Interlaboratory Study conducted by LeRC is presented. Several factors were investigated, including: laboratory, analytical technique, fuel type, concentration, and ashing additive. Conclusions drawn from the statistical analysis will help direct research efforts toward those areas most responsible for the poor interlaboratory analytical results.

  6. Determination of seven trace elements in human milk, powdered cow's milk and infant foods by neutron activation analysis

    International Nuclear Information System (INIS)

    Grimanis, A.P.; Vassilaki-Grimani, M.; Alexiou, D.; Papadatos, C.

    1979-01-01

    The purpose of this study was to apply neutron activation analysis to the determination of seven trace elements (Co, Cr, Cu, Se, Zn, Rb and As) in colostrum, transitional and mature human milk as well as in powdered cow's milk and commercial infant foods, and thus to find out whether non-breast-fed infants received the same or different amounts of these trace elements as breast-fed ones. Ranges and averages for trace elements in mature human milk, expressed as microgrammes per gramme wet weight, varied as follows: Cr 0.018-0.040 and 0.027; Co 0.0013-0.0030 and 0.0020; Cu 0.38-0.50 and 0.46; Se 0.011-0.022 and 0.015; Zn 1.4-1.7 and 1.5; Rb 0.60-0.66 and 0.63; and As 0.0016-0.0060 and 0.0032. The mean concentrations of the essential trace elements Zn, Se, Cu, Cr and Co in colostrum were, respectively, 3.7, 3.2, 2.4, 1.8 and 1.7 times higher than those in mature human milk. No significant differences in Rb and As concentrations were found between colostrum and mature milk. Average values of Zn and Cu in transitional human milk were, respectively, 3.4 and 1.5 times higher than in mature milk. No significant differences for the rest of the elements were found between these two milk samples. The two milk formulas, half-cream and humanized, contained higher mean concentrations of Zn, Rb and As and similar or lower concentrations of Cr, Co and Se than mature human milk. Half-cream is deficient in Cu; mature human milk contains about 9 times more Cu than the half-cream cow's milk. Humanized milk contains a similar mean concentration of Cu as the mature milk. All examined infant foods contained similar or higher concentrations of all elements determined than did the mature human milk

  7. Direct Position Determination of Unknown Signals in the Presence of Multipath Propagation

    Directory of Open Access Journals (Sweden)

    Jianping Du

    2018-03-01

    Full Text Available A novel geolocation architecture, termed “Multiple Transponders and Multiple Receivers for Multiple Emitters Positioning System (MTRE” is proposed in this paper. Existing Direct Position Determination (DPD methods take advantage of a rather simple channel assumption (line of sight channels with complex path attenuations and a simplified MUltiple SIgnal Classification (MUSIC algorithm cost function to avoid the high dimension searching. We point out that the simplified assumption and cost function reduce the positioning accuracy because of the singularity of the array manifold in a multi-path environment. We present a DPD model for unknown signals in the presence of Multi-path Propagation (MP-DPD in this paper. MP-DPD adds non-negative real path attenuation constraints to avoid the mistake caused by the singularity of the array manifold. The Multi-path Propagation MUSIC (MP-MUSIC method and the Active Set Algorithm (ASA are designed to reduce the dimension of searching. A Multi-path Propagation Maximum Likelihood (MP-ML method is proposed in addition to overcome the limitation of MP-MUSIC in the sense of a time-sensitive application. An iterative algorithm and an approach of initial value setting are given to make the MP-ML time consumption acceptable. Numerical results validate the performances improvement of MP-MUSIC and MP-ML. A closed form of the Cramér–Rao Lower Bound (CRLB is derived as a benchmark to evaluate the performances of MP-MUSIC and MP-ML.

  8. Direct Position Determination of Unknown Signals in the Presence of Multipath Propagation.

    Science.gov (United States)

    Du, Jianping; Wang, Ding; Yu, Wanting; Yu, Hongyi

    2018-03-17

    A novel geolocation architecture, termed "Multiple Transponders and Multiple Receivers for Multiple Emitters Positioning System (MTRE)" is proposed in this paper. Existing Direct Position Determination (DPD) methods take advantage of a rather simple channel assumption (line of sight channels with complex path attenuations) and a simplified MUltiple SIgnal Classification (MUSIC) algorithm cost function to avoid the high dimension searching. We point out that the simplified assumption and cost function reduce the positioning accuracy because of the singularity of the array manifold in a multi-path environment. We present a DPD model for unknown signals in the presence of Multi-path Propagation (MP-DPD) in this paper. MP-DPD adds non-negative real path attenuation constraints to avoid the mistake caused by the singularity of the array manifold. The Multi-path Propagation MUSIC (MP-MUSIC) method and the Active Set Algorithm (ASA) are designed to reduce the dimension of searching. A Multi-path Propagation Maximum Likelihood (MP-ML) method is proposed in addition to overcome the limitation of MP-MUSIC in the sense of a time-sensitive application. An iterative algorithm and an approach of initial value setting are given to make the MP-ML time consumption acceptable. Numerical results validate the performances improvement of MP-MUSIC and MP-ML. A closed form of the Cramér-Rao Lower Bound (CRLB) is derived as a benchmark to evaluate the performances of MP-MUSIC and MP-ML.

  9. Direct Position Determination of Unknown Signals in the Presence of Multipath Propagation

    Science.gov (United States)

    Yu, Hongyi

    2018-01-01

    A novel geolocation architecture, termed “Multiple Transponders and Multiple Receivers for Multiple Emitters Positioning System (MTRE)” is proposed in this paper. Existing Direct Position Determination (DPD) methods take advantage of a rather simple channel assumption (line of sight channels with complex path attenuations) and a simplified MUltiple SIgnal Classification (MUSIC) algorithm cost function to avoid the high dimension searching. We point out that the simplified assumption and cost function reduce the positioning accuracy because of the singularity of the array manifold in a multi-path environment. We present a DPD model for unknown signals in the presence of Multi-path Propagation (MP-DPD) in this paper. MP-DPD adds non-negative real path attenuation constraints to avoid the mistake caused by the singularity of the array manifold. The Multi-path Propagation MUSIC (MP-MUSIC) method and the Active Set Algorithm (ASA) are designed to reduce the dimension of searching. A Multi-path Propagation Maximum Likelihood (MP-ML) method is proposed in addition to overcome the limitation of MP-MUSIC in the sense of a time-sensitive application. An iterative algorithm and an approach of initial value setting are given to make the MP-ML time consumption acceptable. Numerical results validate the performances improvement of MP-MUSIC and MP-ML. A closed form of the Cramér–Rao Lower Bound (CRLB) is derived as a benchmark to evaluate the performances of MP-MUSIC and MP-ML. PMID:29562601

  10. Graphite electrodes modified by 8-hydroxyquinolines and its application for the determination of copper in trace levels

    Directory of Open Access Journals (Sweden)

    Sousa Eliane R. de

    2006-01-01

    Full Text Available Surface modification by 8-hydroxyquinoline-5-sulfonic acid (8-HQS or 8-hydroxyquinoline (8-HQ on a graphite electrode through irreversible adsorption is reported in this paper. Cyclic voltammetry was used to characterize the surface behavior. The modified surface exhibited an affinity to chelating Cu(II in the solution, forming a Cu(II complex, which was employed for Cu(II trace analysis. Of the metals Zn, Ni, Pb, Co, and Cd, none presented interference until excess concentration of 10 times. Significant interference could be observed from Co(II, Cd(II and Fe(II for an excess concentration of 100 times on the analyte. A differential pulse voltammetry, combined with a preconcentrating-stripping process and a standard addition method was used for the analysis. A detection limit for trace copper determination in water, such as 5.110-9 mol L-1, was obtained.

  11. Determination of Trace Iron in Red Wine by Isotope Dilution Mass Spectrometry Using Multiple-Collector Inductively Coupled Plasma Mass Spectrometry

    International Nuclear Information System (INIS)

    Zhou Tao; Wang Jun; Lu Hai; Zhou Yuanjing; Li Haifeng

    2009-01-01

    This paper introduces determination of trace iron in red wine certified reference material by isotope dilution mass spectrometry (IDMS) method using a multiplecollector inductively coupled plasma mass spectrometry, equipped with a hexapole collision cell. The measurement procedure of iron isotopic abundance ratios was deeply researched. Reduced polyatomic ion interferences to iron isotopes ion by collision reaction using Ar and H 2 gas, high precise isotopic abundance ratios were achieved. Two relative measurement methods (ICP-MS and ICP-OES) were used to analyze trace iron in red wine. The results are compared with IDMS results, which indicate that they are accordant. The uncertainty analyses include each uncertainty factor in whole experiment and the uncertainty of used certified reference material and it shows that the procedure blank is not neglectable to detect limit and precision of the method. The establishment of IDMS method for analysis of trace iron in red wine supports the certification of certified reference materials. (authors)

  12. Detection of viral sequence fragments of HIV-1 subfamilies yet unknown

    Directory of Open Access Journals (Sweden)

    Stanke Mario

    2011-04-01

    Full Text Available Abstract Background Methods of determining whether or not any particular HIV-1 sequence stems - completely or in part - from some unknown HIV-1 subtype are important for the design of vaccines and molecular detection systems, as well as for epidemiological monitoring. Nevertheless, a single algorithm only, the Branching Index (BI, has been developed for this task so far. Moving along the genome of a query sequence in a sliding window, the BI computes a ratio quantifying how closely the query sequence clusters with a subtype clade. In its current version, however, the BI does not provide predicted boundaries of unknown fragments. Results We have developed Unknown Subtype Finder (USF, an algorithm based on a probabilistic model, which automatically determines which parts of an input sequence originate from a subtype yet unknown. The underlying model is based on a simple profile hidden Markov model (pHMM for each known subtype and an additional pHMM for an unknown subtype. The emission probabilities of the latter are estimated using the emission frequencies of the known subtypes by means of a (position-wise probabilistic model for the emergence of new subtypes. We have applied USF to SIV and HIV-1 sequences formerly classified as having emerged from an unknown subtype. Moreover, we have evaluated its performance on artificial HIV-1 recombinants and non-recombinant HIV-1 sequences. The results have been compared with the corresponding results of the BI. Conclusions Our results demonstrate that USF is suitable for detecting segments in HIV-1 sequences stemming from yet unknown subtypes. Comparing USF with the BI shows that our algorithm performs as good as the BI or better.

  13. Trace aluminium determination and sampling problems of archeological bone employing destructive neutron activation analysis

    International Nuclear Information System (INIS)

    Blotcky, A.J.; Rack, E.P.; Recker, R.R.; Leffler, J.A.; Teitelbaum, S.

    1978-01-01

    A destructive neutron activation analysis procedure was developed for determining trace aluminium content in bone. The method is based on a carefully planned sample preparation, irradiation at a neutron flux for 3.1x10 11 nxcm -2 xs -1 for 5 minutes, and chemical separation based on ion exchange. It was found that bone samples soaked in aluminium containing soil gave highly elevated aluminium values as a result of the aluminium adsorption into the bone matrix. The maximum aluminium content values for prehistoric bones are larger than those of modern bones and comparable to aluminium levels present in bone from renal patients. (T.G.)

  14. Trace elements in Australian opals using neutron activation analysis

    International Nuclear Information System (INIS)

    McOrist, G.D.; Fardy, J.J.

    1994-01-01

    Neutron activation analysis was used to determine the concentration of trace elements in 42 samples of black, grey and white opals taken from a number of recognised Australian field. The results were evaluated to determine if a relationship exited between trace element content and opal colour. (author) 12 refs.; 12 figs.; 3 tabs

  15. Determination of rare earths and traces of other elements by neutron activation analysis

    International Nuclear Information System (INIS)

    Atalla, L.T.; Mantovani, M.S.M.; Marques, L.S.

    A complete methodology for a multielemental analysis in geological material using the neutron activation technique was developed. 21 trace elements (9 of which are rare earths) were determined using thermal and epithermal neutron irradiations. Instrumetnal and radiochemical processing, applied to BCR-1 and G-2 geological standards, are described. Statistical tests carried out on G-2 data show an error smaller than 15% referring to all elements except Cr, Sb and Yb. The observed differences between are discussed. The good precision attained in this method is confirmed by its application to BCR-1 standard, which presents errors smaller than 4% for all elements except Nd, due to its intrinsic properties. The results from the present work are compared with those from other laboratories. (C.L.B.) [pt

  16. Worldwide Interlaboratory Comparison on the Determination of Trace Elements in the IAEA-457 Marine Sediment Sample

    International Nuclear Information System (INIS)

    2016-01-01

    The primary goal of the IAEA Environment Laboratories is to assist Member States in the use of both stable and radioisotope analytical techniques to understand, monitor and protect the environment. In this context, the major impact of large coastal cities on marine ecosystems is an issue of primary concern for the IAEA and the IAEA Environment Laboratories. The marine pollution assessments required to understand such impacts depend on accurate knowledge of contaminant concentrations in various environmental compartments. Through the IAEA Environment Laboratories, the IAEA has been assisting national laboratories and regional laboratory networks since the early 1970s through the provision of a reference material programme for the analysis of radionuclides, trace elements and organic compounds in marine samples. Quality assurance and quality control are two fundamental requirements to ensure the reliability of analytical results. Data that are not based on adequate quality assurance and quality control can be erroneous, and their misuse can lead to poor environmental management decisions. In this regard, the IAEA has a long history of organizing interlaboratory studies, which have evolved to include an increasing array of potential contaminants in the marine environment. Relevant activities comprise global interlaboratory comparison, regional proficiency tests, the production of marine reference materials and the development of reference methods for trace elements and organic pollutants analysis in marine samples. This publication summarizes the results of the IAEA-457 interlaboratory comparison on the determination of trace elements in a marine sediment sample

  17. Determination of trace elements in fisheries samples by instrumental neutron and photon activation analysis

    International Nuclear Information System (INIS)

    Chattopadhyay, A.; Ellis, K.M.; Nimalasiri Desilva, K.

    1979-01-01

    An instrumental neutron activation analysis (INAA) method has been developed for the simultaneous determination of trace concentrations of up to 23 elements in fisheries samples. The INAA method consists of irradiations of wet and lyophilized cod muscle and liver samples for three different periods at a flux density of 5x10 11 n.cm -2 .s -1 and subsequent measurements after four different decay periods using high-resolution Ge(Li) gamma-ray spectrometry. Concentrations of several essential and toxic elements have been determined. Loss of certain elements during lyophilization has been studied. Elemental distribution in muscles and livers as a function of the age of fish has been investigated. Precision and accuracy of the INAA method have been evaluated by analysing replicate samples, National Bureau of Standards' bovine liver standard reference material, and an intercalibration fish flour sample provided by the International Council for the Exploration of the Sea. A few fish samples have also been analysed by an alternative method, namely instrumental photon activation analysis (IPAA). Elemental concentrations determined by both INAA and IPAA methods are reported here. (author)

  18. Determination of isoniazid concentration in rabbit vertebrae by isotope tracing technique in conjunction with HPLC.

    Science.gov (United States)

    Liu, Peng; Fu, Zhaozong; Jiang, Jianming; Yuan, Liang; Lin, Zhen

    2013-09-01

    Medications compounded with isoniazid (INH) are usually applied to surgical sites at the completion of surgery to locally kill postoperative residual tubercle bacilli. However, the distribution and elimination of INH in the vertebrae in vivo are not known. In this study, isotope tracing was used in conjunction with high-pressure liquid chromatography (HPLC) to address this. INH and technetium-99 m-labeled INH were applied to the vertebrae of rabbits. After 2 and 6 h, osseous tissues containing INH, as determined by radionuclide imaging, were collected for detection with HPLC. The results showed that INH mainly stayed around the vertebrae 6 h after its application and did not permeate widely into the blood or other organs, except for the kidneys. The standard deviations of INH concentrations in the technetium-99 m-INH group were approximately four-fold smaller than those in the INH group. This method of coupling isotope tracing and HPLC can effectively limit experimental error during sample collection, allowing accurate and reliable identification of the concentration levels of INH in osseous tissues in vivo. Copyright © 2013 John Wiley & Sons, Ltd.

  19. Photometric determination of trace cadmium in waste water drained from uranium mining and water-metallurgy

    International Nuclear Information System (INIS)

    Zhu Zihui; Gu Gang; Xu Quanxiu

    1987-09-01

    Cadmium (Cd) ions react with dithizone to form a pink to red color that can be extracted with chloroform and measured photometrically. Dithizone method is one of standard method to determine trace Cd in the environmental waste water. This method, however, can not be suitable for measuring the trace Cd in the waste water drained from uranium mining and water-metallurgy factory, because this kind of waste water contains magnesium ions as high as 1500 mg/L. One more discomfort is that the method needs to use a large amount of potassium cyanide. The authors, therefore, used potassium fluorine as a precipitator that removed the excess magnesium ions in the experimental system, and try to reduce the amount of potassium cyanide to 1/20 of original usage. The experimental results indicated that the modified method as mentioned above was very satisfactory either to simulated samples or to actual samples of waste water drained from uranium mining and water-metallurgy plants. In Summary, this modified method has higher sensitivity with minimun detectable quantity of 0.02 ppm and it is accurate and reproducible with recovery rate of 100 ± 5%

  20. Spectroscopic Determination of Trace Contaminants in High Purity Oxygen

    Science.gov (United States)

    Hornung, Steven D.

    2011-01-01

    Oxygen used for extravehicular activities (EVA) must be free of contaminants because a difference in a few tenths of a percent of argon or nitrogen content can mean significant reduction in available EVA time. These inert gases build up in the extravehicular mobility unit because they are not metabolized or scrubbed from the atmosphere. Measurement of oxygen purity above 99.5% is problematic, and currently only complex instruments such as gas chromatographs or mass spectrometers are used for these determinations. Because liquid oxygen boil-off from the space shuttle will no longer be available to supply oxygen for EVA use, other concepts are being developed to produce and validate high purity oxygen from cabin air aboard the International Space Station. A prototype optical emission technique capable of detecting argon and nitrogen below 0.1% in oxygen was developed at White Sands Test Facility. This instrument uses a glow discharge in reduced pressure gas to produce atomic emission from the species present. Because the atomic emission lines from oxygen, nitrogen, and argon are discrete and in many cases well-separated, trace amounts of argon and nitrogen can be detected in the ultraviolet and visible spectrum. This is a straightforward, direct measurement of the target contaminants and may lend itself to a device capable of on-orbit verification of oxygen purity. System design and optimized measurement parameters are presented.

  1. Trace element fingerprinting of emeralds by PIXE/PIGE

    International Nuclear Information System (INIS)

    Ma Xinpei; MacArthur, J.D.; Roeder, P.L.; Mariano, A.N.

    1993-01-01

    Gemologists consider the mineral beryl, beryllium aluminium silicate, to be the gem, emerald, when it contains sufficient chromium, >0.1%, to colour it a strong green. Emeralds usually contain other trace elements. To investigate the feasibility of distinguishing an emerald's country of origin through its trace content, the trace elements in emeralds and a few beryls from sixteen locations have been determined with a single nondestructive measurement using PIXE and PIGE. From the database established with this limited number of samples, distinguishing trace element patterns were found. (orig.)

  2. Advanced functional materials in solid phase extraction for ICP-MS determination of trace elements and their species - A review.

    Science.gov (United States)

    He, Man; Huang, Lijin; Zhao, Bingshan; Chen, Beibei; Hu, Bin

    2017-06-22

    For the determination of trace elements and their species in various real samples by inductively coupled plasma mass spectrometry (ICP-MS), solid phase extraction (SPE) is a commonly used sample pretreatment technique to remove complex matrix, pre-concentrate target analytes and make the samples suitable for subsequent sample introduction and measurements. The sensitivity, selectivity/anti-interference ability, sample throughput and application potential of the methodology of SPE-ICP-MS are greatly dependent on SPE adsorbents. This article presents a general overview of the use of advanced functional materials (AFMs) in SPE for ICP-MS determination of trace elements and their species in the past decade. Herein the AFMs refer to the materials featuring with high adsorption capacity, good selectivity, fast adsorption/desorption dynamics and satisfying special requirements in real sample analysis, including nanometer-sized materials, porous materials, ion imprinting polymers, restricted access materials and magnetic materials. Carbon/silica/metal/metal oxide nanometer-sized adsorbents with high surface area and plenty of adsorption sites exhibit high adsorption capacity, and porous adsorbents would provide more adsorption sites and faster adsorption dynamics. The selectivity of the materials for target elements/species can be improved by using physical/chemical modification, ion imprinting and restricted accessed technique. Magnetic adsorbents in conventional batch operation offer unique magnetic response and high surface area-volume ratio which provide a very easy phase separation, greater extraction capacity and efficiency over conventional adsorbents, and chip-based magnetic SPE provides a versatile platform for special requirement (e.g. cell analysis). The performance of these adsorbents for the determination of trace elements and their species in different matrices by ICP-MS is discussed in detail, along with perspectives and possible challenges in the future

  3. Determination of natural and artificial radionuclides and some trace metals in manufactured food of Syrian infant and their intake rates

    International Nuclear Information System (INIS)

    Al-Masri, M. S.; Nashawati, A.; Amin, Y.; Ibrahim, S.

    2001-06-01

    Natural and artificial radionuclides and some trace metals in some manufactured food of Syrian infant and their intake rates have been determined. Seventeen manufactured food and eleven types of canned milked, were collected from the local market, and chemically and radioactivity analyzed; radium-226, radium-228, potassium-40, lead-210, polonium-210 and trace metals (Pb, Cd, Cu, Zn) being determined. Results have shown that 210 Po concentration varied between 0.38 and 2.89 Bq/Kg in canned milk while the highest concentration in infant food was found to be 1.69 Bq/Kg; other radionuclides concentration being below the limit of detection. Total uranium concentration varied between 2.2 and 10.5 μg/Kg in milk samples and 0.78-6.0 μg/Kg in food stuff samples. In addition, concentration of Pb and Cd in all samples were found to be very low and lower than the lower of limit of detection of the analytical method. (author)

  4. Determination of ultra-trace aluminum in human albumin by cloud point extraction and graphite furnace atomic absorption spectrometry.

    Science.gov (United States)

    Sun, Mei; Wu, Qianghua

    2010-04-15

    A cloud point extraction (CPE) method for the preconcentration of ultra-trace aluminum in human albumin prior to its determination by graphite furnace atomic absorption spectrometry (GFAAS) had been developed in this paper. The CPE method was based on the complex of Al(III) with 1-(2-pyridylazo)-2-naphthol (PAN) and Triton X-114 was used as non-ionic surfactant. The main factors affecting cloud point extraction efficiency, such as pH of solution, concentration and kind of complexing agent, concentration of non-ionic surfactant, equilibration temperature and time, were investigated in detail. An enrichment factor of 34.8 was obtained for the preconcentration of Al(III) with 10 mL solution. Under the optimal conditions, the detection limit of Al(III) was 0.06 ng mL(-1). The relative standard deviation (n=7) of sample was 3.6%, values of recovery of aluminum were changed from 92.3% to 94.7% for three samples. This method is simple, accurate, sensitive and can be applied to the determination of ultra-trace aluminum in human albumin. 2009 Elsevier B.V. All rights reserved.

  5. Contributions te the study of methods and factors affecting the spectrophotometric determination of boron traces with carmin uranium compounds

    International Nuclear Information System (INIS)

    Fernandez Cellini, R.; Gasco Sanchez, L.

    1956-01-01

    The study of some factors affecting the spectrophotometric determination of boron traces with carmin is made; the influence of carmin from different origin, the stability of complex carmin-boric acid in relation with the sulphuric acid concentration, the interference produced by ion nitrate, and the ion uraline and light influence are discussed. (Author) 36 refs

  6. Temporally rendered automatic cloud extraction (TRACE) system

    Science.gov (United States)

    Bodrero, Dennis M.; Yale, James G.; Davis, Roger E.; Rollins, John M.

    1999-10-01

    Smoke/obscurant testing requires that 2D cloud extent be extracted from visible and thermal imagery. These data are used alone or in combination with 2D data from other aspects to make 3D calculations of cloud properties, including dimensions, volume, centroid, travel, and uniformity. Determining cloud extent from imagery has historically been a time-consuming manual process. To reduce time and cost associated with smoke/obscurant data processing, automated methods to extract cloud extent from imagery were investigated. The TRACE system described in this paper was developed and implemented at U.S. Army Dugway Proving Ground, UT by the Science and Technology Corporation--Acuity Imaging Incorporated team with Small Business Innovation Research funding. TRACE uses dynamic background subtraction and 3D fast Fourier transform as primary methods to discriminate the smoke/obscurant cloud from the background. TRACE has been designed to run on a PC-based platform using Windows. The PC-Windows environment was chosen for portability, to give TRACE the maximum flexibility in terms of its interaction with peripheral hardware devices such as video capture boards, removable media drives, network cards, and digital video interfaces. Video for Windows provides all of the necessary tools for the development of the video capture utility in TRACE and allows for interchangeability of video capture boards without any software changes. TRACE is designed to take advantage of future upgrades in all aspects of its component hardware. A comparison of cloud extent determined by TRACE with manual method is included in this paper.

  7. Determination of minor-and trace elements in magnesite samples, by activation analysis

    International Nuclear Information System (INIS)

    Sepulveda Munita, C.J.A.

    1979-01-01

    A method employing activation analysis with thermal neutron was developed for the determination of minor and trace elements in magnesite samples from the states of Ceara and Bahia (Brazil). Ten samples were analyzed. A qualitative analysis of the samples indicated the presence of Mn, Fe, Sc, Ca, Cu, Co and some of the lanthanides. The experimental part includes a non-destructive analysis of manganese and analysis with chemical separation of the other elements, individually or in groups, after sample dissolution, The dissolutions were made with concentrated HCl and the further separations were carried out in 8 N HCl medium. Iron was separated by means of an extraction of HFeCl 4 with isopropyl ether. Scandium and calcium were determined by retention of scandium with di-(2-ehylhexyl) phosphoric acid (HDEHP). The activities of 46 Sc and 47 Sc (a 47 Ca descendant) were employed for the analysis of scandium and calcium in the sample. In the effluent of the kieselguhr column copper and cobalt were determined, after retention in an anionic resin of the CuCl - 3 and CoCl - 3 complexes. Finally, in the effluent of the resin, the lanthanide group was separated by oxalate precipitation. In the gamma-ray spectrum of this precipitate the elements europium, cerium, samarium and lanthanum were determined. A detailed study of the possible interferences in the neutron activation analysis of the elements analysed was also made. The precision and accuracy of the results obtained and the sensitivity of the method are discussed. (Author) [pt

  8. A Fast Radiochemical Method for the Determination of Some Essential Trace Elements in Biology and Medicine

    International Nuclear Information System (INIS)

    Samsahl, K.

    1964-12-01

    A method has been developed for the determination with neutron-activation analysis of the following trace elements in soft biological tissues: Br, Ca, Cl, Cu, K, Mg, Mn, Mo, Na, P, Sr and Zn. The method consists in performing a short-term irradiation of the samples with a high thermal neutron flux, followed by fast chemical separations and gamma-spectrometric measurements. The chemical separations and the measurements of short-lived nuclides from a run are finished within 70 min, after the end of irradiation

  9. A Fast Radiochemical Method for the Determination of Some Essential Trace Elements in Biology and Medicine

    Energy Technology Data Exchange (ETDEWEB)

    Samsahl, K

    1964-12-15

    A method has been developed for the determination with neutron-activation analysis of the following trace elements in soft biological tissues: Br, Ca, Cl, Cu, K, Mg, Mn, Mo, Na, P, Sr and Zn. The method consists in performing a short-term irradiation of the samples with a high thermal neutron flux, followed by fast chemical separations and gamma-spectrometric measurements. The chemical separations and the measurements of short-lived nuclides from a run are finished within 70 min, after the end of irradiation.

  10. Spectrofluorimetric determination of trace amount of coenzyme II using ciprofloxacin-terbium complex as a fluorescent probe

    International Nuclear Information System (INIS)

    Bian Weiwei; Wang Yusheng; Zhu Xiaojing; Jiang Chongqiu

    2006-01-01

    A new spectrofluorimetric method was developed for the determination of trace amount of nicotinamide adenine dinucleotide phosphate (NADP). Using terbium ion (Tb 3+ )-ciprofloxacin (CIP) complex as a fluorescent probe, in the buffer solution of pH=9.00, NADP can remarkably enhance the fluorescence intensity of the Tb 3+ -CIP complex at λ=545nm and the enhanced fluorescence intensity of Tb 3+ ion is in proportion to the concentration of NADP. Optimum conditions for the determination of NADP were also investigated. The dynamic range for the determination of NADP is 4.9x10 -7 -3.7x10 -6 molL -1 with detection limit of 1.3x10 -7 molL -1 . This method is simple, practical and relatively free interference from coexisting substances and can be successfully applied to determination of NADP in synthetic water samples. Moreover, the enhancement mechanisms of the fluorescence intensity in the Tb 3+ -CIP system and the Tb 3+ -CIP-NADP system have been also discussed

  11. Determination of trace elements in total particulate matter of cigarette smoke by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Mishra, U.C.; Shaikh, G.N.

    1985-01-01

    Cigarette smoke contains many trace elements hazardous for human body. Tobacco samples were analyzed for their trace element contents and the results were reported earlier. This paper presents results on the trace element content analyzed in cigarette smoke using an automatic smoking machine developed in laboratory to simulate actual smoking pattern. The trace element levels in the total particulate matter samples of the cigarette smoke collected on filter papers were measured and compared with those of cigarette smoke condensate reported in the literature. Both methods of collection give comparable results. (author)

  12. Trace elements in coloured opals using neutron activation analysis

    Energy Technology Data Exchange (ETDEWEB)

    McOrist, G D; Smallwood, A [Australian Nuclear Science and Technology Organisation, Lucas Heights, NSW (Australia)

    1997-12-31

    Neutron activation analysis (NAA) is a technique particularly suited to analysing opals since it is non-destructive and the silica matrix of opals is not prone to significant activation. It was used to determine the concentration of trace elements in 50 samples of orange, yellow, green, blue and pink opals as well as 18 samples of colourless opals taken from a number of recognised fields in Australia, Peru, Mexico and USA. The results were then evaluated to determine if a relationship existed between trace element content and opal colour. The mean concentration of most of the elements found in orange, yellow and colourless opals were similar with few exceptions. This indicated that, for these samples, colour is not related to the trace elements present. However, the trace element profile of the green, pink and blue opals was found to be significantly different with each colour having a much higher concentration of certain trace elements when compared with all other opals analysed. 7 refs.

  13. Trace elements in coloured opals using neutron activation analysis

    International Nuclear Information System (INIS)

    McOrist, G.D.; Smallwood, A.

    1996-01-01

    Neutron activation analysis (NAA) is a technique particularly suited to analysing opals since it is non-destructive and the silica matrix of opals is not prone to significant activation. It was used to determine the concentration of trace elements in 50 samples of orange, yellow, green, blue and pink opals as well as 18 samples of colourless opals taken from a number of recognised fields in Australia, Peru, Mexico and USA. The results were then evaluated to determine if a relationship existed between trace element content and opal colour. The mean concentration of most of the elements found in orange, yellow and colourless opals were similar with few exceptions. This indicated that, for these samples, colour is not related to the trace elements present. However, the trace element profile of the green, pink and blue opals was found to be significantly different with each colour having a much higher concentration of certain trace elements when compared with all other opals analysed. 7 refs

  14. Trace elements in coloured opals using neutron activation analysis

    Energy Technology Data Exchange (ETDEWEB)

    McOrist, G.D.; Smallwood, A. [Australian Nuclear Science and Technology Organisation, Lucas Heights, NSW (Australia)

    1996-12-31

    Neutron activation analysis (NAA) is a technique particularly suited to analysing opals since it is non-destructive and the silica matrix of opals is not prone to significant activation. It was used to determine the concentration of trace elements in 50 samples of orange, yellow, green, blue and pink opals as well as 18 samples of colourless opals taken from a number of recognised fields in Australia, Peru, Mexico and USA. The results were then evaluated to determine if a relationship existed between trace element content and opal colour. The mean concentration of most of the elements found in orange, yellow and colourless opals were similar with few exceptions. This indicated that, for these samples, colour is not related to the trace elements present. However, the trace element profile of the green, pink and blue opals was found to be significantly different with each colour having a much higher concentration of certain trace elements when compared with all other opals analysed. 7 refs.

  15. Levels of trace elements in different varieties of wheat determined by Atomic Absorption Spectroscopy

    International Nuclear Information System (INIS)

    Mohamed, A.E.; Taha, G.M.

    2003-01-01

    Trace elements Ag, Au, Ca, Co, Cr, Cu, Fe, K, Mg, Mn, Na, Ni, Pb, Sr and Zn were determined in six wheat samples purchased from the open market in different localities (Egypt, Saudi Arabia, Yemen, Oman, Dubai and Australia). The dried powdered samples were decomposed in HNO3-HClO4 acids mixtures and elements were determined using recording atomic absorption spectrophotometer. The results were within the safety baseline of all the assayed elements. Certified biological standards, Brown's Kale (BK), Orchard Leaves (OL) and tomato leaves (TOML) were used to assure the accuracy of results. However, Co, Pb and Sr were absent from samples except the Egyptian samples. The obtained databases were statistically treated. Several significant and strong positive correlation coefficients (r=0.506-1.00) between the groups of elements were observed. On the other hand, strong negative correlations (r=0.492-0.873) between another group of elements were also shown. (author)

  16. Determination of arsenic and other trace elements in cosmetics by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Gonzalez Cepeda, A.M.; Cienfuegos Silva, E.E.

    1978-01-01

    A general survey of trace-elements in different types of cosmetics, in particular arsenic, was carried out in order to detect elements that might be detrimental to human health. The samples were analyzed by instrumental neutron activation analysis and high-resolution gamma-ray spectrometry with Ge(Li) detectors. Different amounts of Br and Sb, detected in almost all the samples, produced interferencies in the determination of As when the 559 KeV photopeak was used. Since the triplet formed could not be resolved by the Ge(Li) detector, a mathematical procedure was developed using the 776 KeV gamma-ray emission of 82-Br and various factors found experimentally. This procedure was checked using laboratory-made samples of known concentrations and the results obtained had good precision and accuracy. In addition to arsenic the elements Co, Cr, Br, Sc, Fe and Zn were also quantitatively determined. Those cosmetics made from inorganic raw materials have an As concentration higher than those elaborated from organic materials. (EC)

  17. Multi-elemental determination of trace elements in deep seawater by inductively coupled plasma mass spectrometry with resin preconcentration

    International Nuclear Information System (INIS)

    Sumida, Takashi; Nakazato, Tetsuya; Tao, Hiroaki

    2003-01-01

    A miniaturized column (ca. 3 mm i.d., 40 mm length), packed with a chelating resin (0.2 g) with iminodiacetic acid groups (Muromac A-1), was tested for the preconcentration of trace elements in seawater. After preconcentration, the column was washed with ammonium acetate buffer (pH 5.5) and water to remove the major elements, such as Ca and Mg, and was then eluted with 4 ml of 2 mol l -1 nitric acid. Twenty-six trace elements were determined by inductively coupled plasma mass spectrometry and inductively coupled plasma emission spectrometry. The necessary volume of the seawater sample was only 200 ml. The recoveries for most of the elements tested were over 90%, although those for Al, V and Th were around 70%. The trueness and precision were evaluated by analyzing a standard reference material of seawater (NASS-4, NRC Canada). The observed values obtained with the present method showed good agreement with the certified values. The present method was also applied to deep seawater samples collected at Muroto, Japan. A difference in the rare earth element pattern, especially the Ce anomaly, between the deep seawater sample and the surface seawater sample was observed, as well as the differences of the concentrations of many trace elements. (author)

  18. Photoresponsive molecularly imprinted hydrogel casting membrane for the determination of trace tetracycline in milk.

    Science.gov (United States)

    Wang, Qiang; Lv, Zhen; Tang, Qian; Gong, Cheng-Bin; Lam, Michael Hon Wah; Ma, Xue-Bing; Chow, Cheuk-Fai

    2016-03-01

    This study aimed to develop a photoresponsive molecularly imprinted hydrogel (MIH) casting membrane for the determination of trace tetracycline (TC) in milk. This MIH casting membrane combined the specificity of MIHs, the photoresponsive properties of azobenzene, and the portable properties of a membrane. Photoresponsive TC-imprinted MIHs were initially fabricated and then cast on sodium dodecyl sulfonate polyacrylamide gel. After TC removal, a photoresponsive MIH casting membrane was obtained. The photoresponsive properties of the MIH casting membrane were robust, and no obvious photodegradation was observed after 20 cycles. The MIH casting membrane displayed specific affinity to TC upon alternate irradiation at 365 and 440 nm; it could quantitatively uptake and release TC. The TC concentration (0.0-2.0 × 10(-4) mol l(-1)) in aqueous solution displayed a linear relationship with the photoisomerization rate constant of azobenzene within the MIH casting membrane. As such, a quick detection method for trace TC in aqueous foodstuff samples was established. The recovery of this method for TC in milk was investigated with a simple pretreatment of milk, and a high recovery of 100.54-106.35% was obtained. Therefore, the fabricated membrane can be used as a portable molecular sensor that can be easily recycled. Copyright © 2015 John Wiley & Sons, Ltd.

  19. Simultaneous determination of macronutrients, micronutrients and trace elements in mineral fertilizers by inductively coupled plasma optical emission spectrometry

    Science.gov (United States)

    de Oliveira Souza, Sidnei; da Costa, Silvânio Silvério Lopes; Santos, Dayane Melo; dos Santos Pinto, Jéssica; Garcia, Carlos Alexandre Borges; Alves, José do Patrocínio Hora; Araujo, Rennan Geovanny Oliveira

    2014-06-01

    An analytical method for simultaneous determination of macronutrients (Ca, Mg, Na and P), micronutrients (Cu, Fe, Mn and Zn) and trace elements (Al, As, Cd, Pb and V) in mineral fertilizers was optimized. Two-level full factorial design was applied to evaluate the optimal proportions of reagents used in the sample digestion on hot plate. A Doehlert design for two variables was used to evaluate the operating conditions of the inductively coupled plasma optical emission spectrometer in order to accomplish the simultaneous determination of the analyte concentrations. The limits of quantification (LOQs) ranged from 2.0 mg kg- 1 for Mn to 77.3 mg kg- 1 for P. The accuracy and precision of the proposed method were evaluated by analysis of standard reference materials (SRMs) of Western phosphate rock (NIST 694), Florida phosphate rock (NIST 120C) and Trace elements in multi-nutrient fertilizer (NIST 695), considered to be adequate for simultaneous determination. Twenty-one samples of mineral fertilizers collected in Sergipe State, Brazil, were analyzed. For all samples, the As, Ca, Cd and Pb concentrations were below the LOQ values of the analytical method. For As, Cd and Pb the obtained LOQ values were below the maximum limit allowed by the Brazilian Ministry of Agriculture, Livestock and Food Supply (Ministério da Agricultura, Pecuária e Abastecimento - MAPA). The optimized method presented good accuracy and was effectively applied to quantitative simultaneous determination of the analytes in mineral fertilizers by inductively coupled plasma optical emission spectrometry (ICP OES).

  20. Method development for trace and ultratrace analysis

    International Nuclear Information System (INIS)

    Anon.

    1992-01-01

    Method development, that is, selection of a mode of chromatography and the right column and mobile-phase combination for trace and ultratrace analysis, requires several main considerations. The method should be useful for resolving various trace and ultratrace components present in the sample. If the nature of these components is known, the choice of method may be straightforward, that is, a selection can be made from the following modes of HPLC: (1) adsorption chromatography; (2) normal-phase chromatography; (3) reversed-phase chromatography; (4) ion-pair chromatography; (5) ion-exchange chromatography; (6) ion chromatography. Unfortunately, the nature of all of the components is frequently unknown. However, several intelligent judgments can be made on the nature of impurities. This chapter deals with some basic approaches to mobile-phase selection and optimization. More detailed information may be found in basic texts. Techniques for separation of high-molecular-weight compounds (macromolecules) and chiral compounds may be found elsewhere. Mainly compounds with molecular weight lower than 2,000 are discussed here. 123 refs

  1. An evaluation of trace element release associated with acid mine drainage

    International Nuclear Information System (INIS)

    Sullivan, P.J.; Yelton, J.L.

    1988-01-01

    The determination of trace element release from geologic materials, such as oil shale and coal overburden, is important for proper solid waste management planning. The objective of this study was to determine a correlation between release using the following methods: (1) sequential selective dissolution for determining trace element residencies, (2) toxicity characteristic leaching procedure (TCLP), and (3) humidity cell weathering study simulating maximum trace element release. Two eastern oil shales were used, a New Albany shale that contains 4.6 percent pyrite, and a Chattanooga shale that contains 1.5 percent pyrite. Each shale was analyzed for elemental concentrations by soluble, adsorbed, organic, carbonate, and sulfide phases. The results of the results of the selective dissolution studies show that each trace element has a unique distribution between the various phases. Thus, it is possible to predict trace element release based on trace element residency. The TCLP results show that this method is suitable for assessing soluble trace element release but does not realistically assess potential hazards. The results of the humidity cell studies do demonstrate a more reasonable method for predicting trace element release and potential water quality hazards. The humidity cell methods, however, require months to obtain the required data with a large number of analytical measurements. When the selective dissolution data are compared to the trace element concentrations in the TCLP and humidity cell leachates, it is shown that leachate concentrations are predicted by the selective dissolution data. Therefore, selective dissolution may represent a rapid method to assess trace element release associated with acid mine drainage

  2. Trace element measurements with synchrotron radiation

    International Nuclear Information System (INIS)

    Hanson, A.L.; Kraner, H.W.; Jones, K.W.; Gordon, B.M.; Mills, R.E.

    1982-01-01

    Aspects of the application of synchrotron radiation to trace element determinations by x-ray fluorescence have been investigated using beams from the Cornell facility, CHESS. Fluoresced x rays were detected with a Si(Li) detector placed 4 cm from the target at 90 0 to the beam. Thick samples of NBS Standard Reference Materials were used to calibrate trace element sensitivity and estimate minimum detectable limits for this method

  3. Determination of essential trace elements in wine by neutron activation analysis

    International Nuclear Information System (INIS)

    Daniele, Anna Paula

    2016-01-01

    Several studies have been carried out for determining essential elements in foodstuffs, including wine, due to its important nutritional role in human body functions. It was shown that daily consumption of wine in moderation contributes significantly to the needs of essential elements in human body such as Ca, Co, Cr, Fe, K, Mg, Mn, Zn, V, among others, and has health benefits in the prevention of numerous diseases and longer life expectancy, related in particular to the intake of antioxidants such as polyphenolic compounds. Trace elements are good indicators of origin of wines and their concentrations can be used as criteria to ensure authenticity, quality and show that the tolerance limits established by law were respected throughout the production process. However, although Brazilian wine industry is among the 15 largest in the world, analytical studies for organic and inorganic compounds of wine content are still small when compared to other major producers. In this sense, this study aimed to evaluate some procedures of wine sample preparation to determine essential elements by Instrumental Neutron Activation Analysis (INAA) and compare the results with those determined by Inductively Coupled Plasma Atomic Emission Spectrometry (ICP OES). Three sample preparation procedures were studied: freeze-drying, evaporation and dry ashing. The parameters studied were precision, accuracy and detection limit. ANOVA and Tukey-Kramer tests were applied to verify the statistical differences between the mean values obtained by the three wine preparation procedures for INAA with those means obtained by ICP OES. It was noticed that about 60% of results obtained by freeze-drying agreed with those obtained by ICP OES. (author)

  4. Exploiting flow Injection and sequential injection schemes for trace metal determinations by electrothermal atomic absorption spectrometry

    DEFF Research Database (Denmark)

    Hansen, Elo Harald

    Determination of low or trace-level amounts of metals by electrothermal atomic absorption spectrometry (ETAAS) often requires the use of suitable preconcentration and/or separation procedures in order to attain the necessary sensitivity and selectivity. Such schemes are advantageously executed...... by superior performance and versatility. In fact, two approaches are conceivable: The analyte-loaded ion-exchange beads might either be transported directly into the graphite tube where they are pyrolized and the measurand is atomized and quantified; or the loaded beads can be eluted and the eluate forwarded...

  5. Influence of trace elements on fluoride uptake by teeth

    Energy Technology Data Exchange (ETDEWEB)

    Chaudhri, M A [Austin Hospital, Heidelberg (Australia). Dept. of Medical Physics; Melbourne Univ., Austin (Australia). Dept. of Medicine); Crawford, A [Melbourne Univ., Parkville (Australia). School of Physics

    1981-03-01

    To investigate the effect of various trace elements on fluoride uptake by teeth, the concentrations of F and other trace elements have been simultaneously determined in different regions of the teeth from children of South Australia. Teeth cross sectioned along the median plane have been used in these investigations, and their inside enamel, dentine and amelodentinal junctions investigated separately for the trace elemental composition. Fluoride has been determined by observing the 6-7 MeV gammas for the /sup 19/F(p,..cap alpha gamma..)/sup 16/O reaction, C by activation through the /sup 12/C(/sup 3/He,n)/sup 14/O reaction, while other trace elements have been measured by the thick target PIXE technique. Linear correlation coefficients have been calculated between the F concentrations in teeth and those of other trace elements observed. Fluoride is found to correlate best with C, Cu and Pb, poorly with Fe, Sr, Ni and Ag, while with Br and Zn it has-ve coefficients. Student's t-test has been applied to the data to examine the significance of the variation of Fand other trace elements amongst different dental tissues from healthy and diseased teeth.

  6. Development of a selective and sensitive flotation method for determination of trace amounts of cobalt, nickel, copper and iron in environmental samples.

    Science.gov (United States)

    Karimi, H; Ghaedi, M; Shokrollahi, A; Rajabi, H R; Soylak, M; Karami, B

    2008-02-28

    A simple, selective and rapid flotation method for the separation-preconcentration of trace amounts of cobalt, nickel, iron and copper ions using phenyl 2-pyridyl ketone oxime (PPKO) has been developed prior to their flame atomic absorption spectrometric determinations. The influence of pH, amount of PPKO as collector, type and amount of eluting agent, type and amount of surfactant as floating agent and ionic strength was evaluated on the recoveries of analytes. The influences of the concomitant ions on the recoveries of the analyte ions were also examined. The enrichment factor was 93. The detection limits based on 3 sigma for Cu, Ni, Co and Fe were 0.7, 0.7, 0.8, and 0.7 ng mL(-1), respectively. The method has been successfully applied for determination of trace amounts of ions in various real samples.

  7. Development of a selective and sensitive flotation method for determination of trace amounts of cobalt, nickel, copper and iron in environmental samples

    International Nuclear Information System (INIS)

    Karimi, H.; Ghaedi, M.; Shokrollahi, A.; Rajabi, H.R.; Soylak, M.; Karami, B.

    2008-01-01

    A simple, selective and rapid flotation method for the separation-preconcentration of trace amounts of cobalt, nickel, iron and copper ions using phenyl 2-pyridyl ketone oxime (PPKO) has been developed prior to their flame atomic absorption spectrometric determinations. The influence of pH, amount of PPKO as collector, type and amount of eluting agent, type and amount of surfactant as floating agent and ionic strength was evaluated on the recoveries of analytes. The influences of the concomitant ions on the recoveries of the analyte ions were also examined. The enrichment factor was 93. The detection limits based on 3 sigma for Cu, Ni, Co and Fe were 0.7, 0.7, 0.8, and 0.7 ng mL -1 , respectively. The method has been successfully applied for determination of trace amounts of ions in various real samples

  8. Trace elements in coloured opals using neutron activation analysis

    International Nuclear Information System (INIS)

    McOrist, G.D.; Smallwood, A.

    1995-01-01

    Neutron activation analysis was used to determine the concentration of trace elements in 50 samples of orange, yellow, honey, green, blue and pink opals as well as 18 samples of colourless opals taken from a number of recognised fields in Australia, Peru, Mexico and USA. The results were evaluated to determine the relationship between trace elements content and opal colour. (author). 10 refs., 10 figs., 3 tabs

  9. Trace element determination study in human hair by neutron activation analysis

    International Nuclear Information System (INIS)

    Frazao, Selma Violato

    2008-01-01

    Human hair analysis studies have been subject of continuous interest due to the fact that they can be used as an important tool to evaluate trace element levels in the human body. These determinations have been carried out to use hair for environmental and occupational monitoring, to identify intoxication or poisoning by toxic metals, to assess nutritional status, to diagnose and to prevent diseases and in forensic sciences. Although hair analysis presents several advantages over other human tissue or fluid analyses, such as organ tissue, blood, urine and saliva, there are some controversies regarding the use of hair analysis data. These controversies arise from the fact that it is difficult to establish reliable reference values for trace elements in hair. The purpose of this study was to evaluate the factors that affect element concentrations in hair samples from a population considered healthy and residing in the Sao Paulo metropolitan area. The collected human head hair was cut in small pieces, washed, dried and analyzed by neutron activation analysis (NAA). Aliquots of hair samples and synthetic elemental standards were irradiated at the IEA-R1 nuclear research reactor for 16 h under a thermal neutron flux of about 5x10 12 n cm -2 s -1 for As, Br, Ca, Co, Cr, Cs, Cu, Fe, K, La, Na, Sb, Sc, Se and Zn determinations. The induced gamma activities of the standards and samples were measured using a gamma ray spectrometer coupled to an hiperpure Ge detector. For quality control of the results, IAEA- 85 Human Hair and INCT-TL-1 Tea Leaves certified reference materials (CRMs) were analyzed. Results obtained in these CRMs presented for most of elements, good agreement with the values of the certificates (relative errors less than 10%) and good precision (variation coefficients less than 13.6%). Results of replicate hair sample analysis showed good reproducibility indicating homogeneity of the prepared sample. Results obtained in the analyses of dyed and non-dyed hair

  10. Determination of trace elements in drinking water by neutron activation analysis

    International Nuclear Information System (INIS)

    Munita, C.S.; Abe, R.M.; Andrade e Silva, L.G. de.

    1988-10-01

    The concentracao of Hg, Cr, Zn, Fe and Co has been determined in fresh drinking water by a combination of preconcentration and neutron activation analysis. In order to preconcentrate the trace metals, a Chelex-100 resin in the NH + - form has been employed and it was not necessary to use special NH 4 + - form has been employed and it was not necessary to use special agents for the adsorption of the elements which are practically quantitatively retained by the resin. The retention of each element during the preconcentration was investigated using radioactive tracers. Selenium is known as a strongly interferent element for the analysis since the (n,Π) produced 75 Se has a Π-line at 0.279 MeV which coincides with the only Π-line of 203 Hg. The separation was made by a selective retention of mercury. After the sample had passed through the resin, the column was transfered to a polythylene envelope and irradiated at a neutron flux of about 5.10 12 ncm -2 s -1 for 8 h. For Hg the resin was irradiated in quartz ampoules. The samples were counted 15 days after the irradiation. The present method is superior to most other Chelex-100 separation procesures where elements of interest are eluted from the resin prior determinations thereby introducing the possibility of additional reagent blanks and incomplete as well as non-reproducible recoveries. (author) [pt

  11. Automated computer analysis of plasma-streak traces from SCYLLAC

    International Nuclear Information System (INIS)

    Whitman, R.L.; Jahoda, F.C.; Kruger, R.P.

    1977-01-01

    An automated computer analysis technique that locates and references the approximate centroid of single- or dual-streak traces from the Los Alamos Scientific Laboratory SCYLLAC facility is described. The technique also determines the plasma-trace width over a limited self-adjusting region. The plasma traces are recorded with streak cameras on Polaroid film, then scanned and digitized for processing. The analysis technique uses scene segmentation to separate the plasma trace from a reference fiducial trace. The technique employs two methods of peak detection; one for the plasma trace and one for the fiducial trace. The width is obtained using an edge-detection, or slope, method. Timing data are derived from the intensity modulation of the fiducial trace. To smooth (despike) the output graphs showing the plasma-trace centroid and width, a technique of ''twicing'' developed by Tukey was employed. In addition, an interactive sorting algorithm allows retrieval of the centroid, width, and fiducial data from any test shot plasma for post analysis. As yet, only a limited set of sixteen plasma traces has been processed using this technique

  12. Automated computer analysis of plasma-streak traces from SCYLLAC

    International Nuclear Information System (INIS)

    Whiteman, R.L.; Jahoda, F.C.; Kruger, R.P.

    1977-11-01

    An automated computer analysis technique that locates and references the approximate centroid of single- or dual-streak traces from the Los Alamos Scientific Laboratory SCYLLAC facility is described. The technique also determines the plasma-trace width over a limited self-adjusting region. The plasma traces are recorded with streak cameras on Polaroid film, then scanned and digitized for processing. The analysis technique uses scene segmentation to separate the plasma trace from a reference fiducial trace. The technique employs two methods of peak detection; one for the plasma trace and one for the fiducial trace. The width is obtained using an edge-detection, or slope, method. Timing data are derived from the intensity modulation of the fiducial trace. To smooth (despike) the output graphs showing the plasma-trace centroid and width, a technique of ''twicing'' developed by Tukey was employed. In addition, an interactive sorting algorithm allows retrieval of the centroid, width, and fiducial data from any test shot plasma for post analysis. As yet, only a limited set of the plasma traces has been processed with this technique

  13. Determination of trace elements in kidneys, livers and brains of rats with sealer implants by ICP-MS

    International Nuclear Information System (INIS)

    Simsek, Neslihan; Akinci, Levent; Alan, Hilal; Gecör, Orhan; Özan, Ülkü

    2017-01-01

    Following root canal treatment, sealers may contact periapical tissue. The purpose of this study was to evaluate the systemic toxic effects of epoxy resin-based sealers (AH Plus and Obtuseal). Inductively coupled plasma-mass spectrometry (ICP-MS) was used to measure levels of trace elements (beryllium, magnesium, aluminium, calcium, chromium, arsenic and lead) in the brain, kidney and liver of rats. Twenty sterilized polyethylene tubes were then filled with AH Plus and Obtuseal and implanted into the dorsal subcutaneous tissue of 10 rats; three unoperated animals were used as a control group. After 45 days, the rats were sacrificed by cervical dislocation following anaesthesia, and brains, kidneys and livers were removed from all experimental animals. ICP-MS analysis was used to determine levels of trace elements. Data were analysed using Kruskal– Wallis and Connover post hoc tests. No significant differences were found in aluminium and calcium levels, but brains, kidneys and livers showed significantly higher amounts of magnesium and chromium than the corresponding controls. In the kidney and liver samples, arsenic levels were found to be higher than in the control group. Lead was detected at higher levels only in liver samples from the AH Plus group. Beryllium was not detected in any organ. It was concluded that AH Plus and Obtuseal release minimal quantities of trace elements when in contact with subcutaneous tissue, and further studies are needed to understand the systemic effects of these materials

  14. Determination of mineral, trace element, and pesticide levels in honey samples originating from different regions of Malaysia compared to manuka honey.

    Science.gov (United States)

    Moniruzzaman, Mohammed; Chowdhury, Muhammed Alamgir Zaman; Rahman, Mohammad Abdur; Sulaiman, Siti Amrah; Gan, Siew Hua

    2014-01-01

    The present study was undertaken to determine the content of six minerals, five trace elements, and ten pesticide residues in honeys originating from different regions of Malaysia. Calcium (Ca), magnesium (Mg), iron (Fe), and zinc (Zn) were analyzed by flame atomic absorption spectrometry (FAAS), while sodium (Na) and potassium (K) were analyzed by flame emission spectrometry (FAES). Trace elements such as arsenic (As), lead (Pb), cadmium (Cd), copper (Cu), and cobalt (Co) were analyzed by graphite furnace atomic absorption spectrometry (GFAAS) following the microwave digestion of honey. High mineral contents were observed in the investigated honeys with K, Na, Ca, and Fe being the most abundant elements (mean concentrations of 1349.34, 236.80, 183.67, and 162.31 mg/kg, resp.). The concentrations of the trace elements were within the recommended limits, indicating that the honeys were of good quality. Principal component analysis reveals good discrimination between the different honey samples. The pesticide analysis for the presence of organophosphorus and carbamates was performed by high performance liquid chromatography (HPLC). No pesticide residues were detected in any of the investigated honey samples, indicating that the honeys were pure. Our study reveals that Malaysian honeys are rich sources of minerals with trace elements present within permissible limits and that they are free from pesticide contamination.

  15. Development of accurate mass spectrometric routine and reference methods for the determination of trace amounts of iridium and rhodium in photographic emulsionsf

    NARCIS (Netherlands)

    Krystek, Petra; Heumann, Klaus G.

    1999-01-01

    For the determination of trace amounts of iridium and rhodium in photographic emulsions different sample treatment procedures were coupled with inductively coupled plasma mass spectrometry (ICP-MS) and, for iridium, also with negative thermal ionisation isotope dilution mass spectrometry (NTI-IDMS)

  16. Allocating monitoring effort in the face of unknown unknowns

    Science.gov (United States)

    Wintle, B.A.; Runge, M.C.; Bekessy, S.A.

    2010-01-01

    There is a growing view that to make efficient use of resources, ecological monitoring should be hypothesis-driven and targeted to address specific management questions. 'Targeted' monitoring has been contrasted with other approaches in which a range of quantities are monitored in case they exhibit an alarming trend or provide ad hoc ecological insights. The second form of monitoring, described as surveillance, has been criticized because it does not usually aim to discern between competing hypotheses, and its benefits are harder to identify a priori. The alternative view is that the existence of surveillance data may enable rapid corroboration of emerging hypotheses or help to detect important 'unknown unknowns' that, if undetected, could lead to catastrophic outcomes or missed opportunities. We derive a model to evaluate and compare the efficiency of investments in surveillance and targeted monitoring. We find that a decision to invest in surveillance monitoring may be defensible if: (1) the surveillance design is more likely to discover or corroborate previously unknown phenomena than a targeted design and (2) the expected benefits (or avoided costs) arising from discovery are substantially higher than those arising from a well-planned targeted design. Our examination highlights the importance of being explicit about the objectives, costs and expected benefits of monitoring in a decision analytic framework. ?? 2010 Blackwell Publishing Ltd/CNRS.

  17. Determination of trace elements in dried sea-plant homogenate (SP-M-1) and in dried copepod homogenate (MA-A-1) by means of neutron activation analysis

    International Nuclear Information System (INIS)

    Tjioe, P.S.; Goeij, J.J.M. de; Bruin, M. de.

    1977-07-01

    Two marine environmental reference materials were investigated in an intercalibration study of trace elements. According to the specifications from the International Laboratory of Marine Radioactivity at Monaco two samples, a sea-plant homogenate and a copepod homogenate, were analysed by neutron activation analysis. The results of the trace-element analyses were based on dry weight. The moisture content was measured on separate aliquots. For the intercalibration study the following elements were listed as elements of primary interest: mercury, cadmium, lead, manganese, zinc, copper, chromium, silver, iron and nickel. For the 14 elements normally analysed with the routine destructive method, the element gold could not be measured in the two marine samples. This was due to the high residual bromine-82 activity in fraction 13, which contains gold that distills over. With the nondestructive method, nine elements could be assessed, of which only three coincide with the 14 elements of the destructive method. A survey of all measured (trace) elements is presented. The 20 (trace) elements measured in the sea-plant homogenate and in the copepod homogenate comprise 8 out of the 10 trace elements of primary interest, all 5 trace elements of secondary interest (arsenic, cobalt, antimony, selenium and vanadium), and 5 additional (trace) elements. The trace-element determination in both marine biological materials via the destructive procedure was carried out in twelve-fold. In the nondestructive procedure quadruple measurements were performed. For all trace-element levels analysed an average value was calculated

  18. Determination of trace elements in scallop and fish otolith by instrumental neutron activation analysis using anti-coincidence and coincidence counting methods

    International Nuclear Information System (INIS)

    Suzuki, Shogo; Okada, Yukiko; Hirai, Shoji

    2005-01-01

    Trace element concentrations in scallop reference material and fish otolith certified reference materials prepared at the National Institute for Environmental Studies (NIES) of Japan were determined by instrumental neutron activation analysis (INAA). Nine aliquots of scallop sample (ca. 252∼507 mg) and five aliquots of fish otolith sample (ca. 502 ∼ 988 mg) and comparative standards were irradiated for a short time (10 s) at a thermal neutron flux of 1.5 x 10 12 n cm -2 s -1 (pneumatic transfer) and for a long time (6 h) at a thermal neutron flux of 3.7 x 10 12 n cm -2 s -1 (central thimble) in the Rikkyo University Research Reactor (100 kW). The irradiated samples were measured by conventional γ-ray spectrometry using a coaxial Ge detector, and by anti-coincidence and coincidence γ-ray spectrometry with a coaxial Ge detector and a well-type NaI (Tl) detector to determine as many trace elements as possible with high sensitivity. The concentrations of 34 elements of the NIES No.15 scallop reference material and 16 elements of the NIES No.22 fish otolith CRM were determined. Using the coincidence counting method to determine Se, Ba and Hf, the lower limit of the determination was improved by 2 times compared with the conventional counting method. (author)

  19. Th, U and trace elements determination in Egyiptian Lake sediments by INAA and laser fluorimetry

    International Nuclear Information System (INIS)

    Ismail, S.S.; Grass, F.; Ghods, A.

    1995-01-01

    A study was undertaken to determine element concentrations in Aswan High Dam Lake sediments. Sediment samples were collected from 40 to 500 km upstream of the dam to follow the sedimentation process and the distribution of Th, U and the trace elements in the lake. INAA was applied for the determination of Sm, Ce, Lu, Th, Cr, Yb, Au, Hf, Ba, Nd, Cs, Tb, Sc, Rb, Fe, Zn, Co, Eu, and Sb, while Laser Fluorimetry was applied for U determination. The accuracy and the reproducibility of the techniques were tested with IAEA standard materials (SL, Soil-7). The U values ranged from 4 ppm to 18 ppm, Th values were between 2 and 10 ppm, and showed a very good correlation with the rare earth elements and Fe. The distribution of most of the elements in the lake follows the same trend as the distribution of the clays in the sediments. Ba showed a negative correlation with most of the elements under investigation. (author) 5 refs.; 4 figs.; 7 tabs

  20. Trace element determination in presolar SiC grains by synchrotron x-ray fluorescence: Commencement of a coordinated multimethod study

    International Nuclear Information System (INIS)

    Knight, K.B.; Sutton, S.R.; Newville, M.; Davis, A.M.; Dauphas, N.; Lewis, R.S.; Amari, S.; Steele, I.M.; Savina, M.R.; Pellin, M.J.

    2008-01-01

    We determined trace element compositions of individual ∼1-3 ?m presolar SiC grains from 6 KJG grains and 26 additionally cleaned KJG grains from the Murchison CM chondrite using nondestructive synchrotron X-ray fluorescence (SXRF). Presolar SiC grains are robust remnants of stellar matter ejected from stars. They survived processing in the early solar system and retain the nucleosynthetic fingerprints of their stellar progenitors. As such, they represent unique physical probes of the interiors of stars. Presolar SiC grains are commonly analyzed by mass spectrometric techniques that determine isotopic compositions and, to some degree, elemental concentrations. These techniques, however, are destructive, and can be subject to matrix effects. Elemental composition data on presolar grains remain scarce and affected by contamination and analytical artifacts. In addition, contamination has plagued isotopic characterization of some elements such as Mo and Ba. We determined trace element compositions of individual ∼1-3 (micro)m presolar SiC grains from the Murchison CM chondrite using nondestructive synchrotron X-ray fluorescence (SXRF). Samples included the KJG fraction, and a second KJG fraction that underwent additional cleaning. As every cleaning step results in some grain loss, one goal of this study was to justify additional cleaning of grains. Six KJG grains and 26 additionally cleaned KJG grains were analyzed, with location and identities of individual grains noted for future correlated isotopic study.

  1. Factors influencing health care workers’ implementation of tuberculosis contact tracing in Kweneng, Botswana

    Science.gov (United States)

    Tlale, Lebapotswe; Frasso, Rosemary; Kgosiesele, Onalenna; Selemogo, Mpho; Mothei, Quirk; Habte, Dereje; Steenhoff, Andrew

    2016-01-01

    Introduction TB contact tracing rates remain low in high burden settings and reasons for this are not well known. We describe factors that influence health care workers' (HCW) implementation of TB contact tracing (CT) in a high TB burden district of Botswana. Methods Data were collected using questionnaires and in-depth interviews in 31 of the 52 health facilities in Kweneng East Health District. Responses were summarized using summary statistics and comparisons between HCW groups were done using parametric or non-parametric tests as per normality of the data distribution. Results One hundred and four HCWs completed questionnaires. Factors that influenced HCW TB contact tracing were their knowledge, attitudes and practices as well as personal factors including decreased motivation and lack of commitment. Patient factors included living further away from the clinic, unknown residential address and high rates of migration and mobility. Administrative factors included staff shortages, lack of transport, poor reporting of TB cases and poor medical infrastructure e.g. suboptimal laboratory services. A national HCW strike and a restructuring of the health system emerged as additional factors during in-depth interviews of TB coordinators. Conclusion Multiple factors lead to poor TB contact tracing in this district. Interventions to increase TB contact tracing will be informed by these findings. PMID:27800084

  2. Derivative flame atomic absorption spectrometry and its application in trace analysis

    International Nuclear Information System (INIS)

    Sun, H. W.; Li, L. Q.

    2005-01-01

    Flame atomic absorption spectrometry is an accepted and widely used method for the determination of trace elements in a great variety of samples. But its sensitivity doesn't meet the demands of trace and ultra-trace analysis for some samples. The derivative signal processing technique, with a very high capability for enhancing sensitivity, was developed for flame atomic absorption spectrometry. The signal models of conventional flame atomic absorption spectrometry are described. The equations of derivative signals are established for flame atomic absorption spectrometry, flow injection atomic absorption spectrometry (FI-FAAS) and atom trapping flame atomic absorption spectrometry (AT-FAAS). The principle and performance of the derivative atomic absorption spectrometry are evaluated. The derivative technique based on determination of variation rate of signal intensity with time (dl/dt) is different from the derivative spectrophotometry based on determination of variation rate of signal intensity with wavelength (dl/dhλ). Derivative flame atomic absorption spectrometry has higher sensitivity, lower detection limits and better accuracy. It has been applied to the direct determination of trace elements without preconcentration. If the derivative technique was combined with several preconcentration techniques, the sensitivity would be enhanced further for ultra-trace analysis with good linearity. The applications of derivative flame atomic absorption spectroscopy are reviewed for trace element analysis in biological, pharmaceutical, environmental and food samples

  3. Financial Development and Economic Growth: Known Knowns, Known Unknowns, and Unknown Unknowns

    OpenAIRE

    Ugo Panizza

    2014-01-01

    This paper summarizes the main findings of the literature on the relationship between financial and economic development (the known knowns), points to directions for future research (the known unknowns), and then speculates on the third Rumsfeldian category. The known knowns section organizes the empirical literature on finance and growth into three strands: (i) the traditional literature which established the link between finance and growth; (ii) the new literature which qualified some of th...

  4. Experimental determination of trace-element partitioning between pargasite and a synthetic hydrous andesitic melt

    Science.gov (United States)

    Brenan, J. M.; Shaw, H. F.; Ryerson, F. J.; Phinney, D. L.

    1995-10-01

    In order to more fully establish a basis for quantifying the role of amphibole in trace-element fractionation processes, we have measured pargasite/silicate melt partitioning of a variety of trace elements (Rb, Ba, Nb, Ta, Hf, Zr, Ce, Nd, Sm, Yb), including the first published values for U, Th and Pb. Experiments conducted at 1000°C and 1.5 GPa yielded large crystals free of compositional zoning. Partition coefficients were found to be constant at total concentrations ranging from ˜ 1 to > 100 ppm, indicating Henry's Law is oparative over this interval. Comparison of partition coefficients measured in this study with previous determinations yields good agreement for similar compositions at comparable pressure and temperature. The compatibility of U, Th and Pb in amphibole decreases in the order Pb > Th > U. Partial melting or fractional crystallization of amphibole-bearing assemblages will therefore result in the generation of excesses in 238U activity relative to 230Th, similar in magnitude to that produced by clinopyroxene. The compatibility of Pb in amphibole relative to U or Th indicates that melt generation in the presence of residual amphibole will result in the long-term enrichment in Pb relative to U or Th in the residue. This process is therefore incapable of producing the depletion in Pb relative to U or Th inferred from the Pb isotopic composition of MORB and OIB. Comparison of partition coefficients measured in this study with previous values for clinopyroxene allows some distinction to be made between expected trace-element fractionations produced during dry (cpx present) and wet (cpx + amphibole present) melting. Rb, Ba, Nb and Ta are dramatically less compatible in clinopyroxene than in amphibole, whereas Th, U, Hf and Zr have similar compatibilities in both phases. Interelement fractionations, such as DNb/DBa are also different for clinopyroxene and amphibole. Changes in certain ratios, such as Ba/Nb, Ba/Th, and Nb/Th within comagmatic suites may

  5. Practical applications of trace minerals for dairy cattle.

    Science.gov (United States)

    Overton, T R; Yasui, T

    2014-02-01

    Trace minerals have critical roles in the key interrelated systems of immune function, oxidative metabolism, and energy metabolism in ruminants. To date, the primary trace elements of interest in diets for dairy cattle have included Zn, Cu, Mn, and Se although data also support potentially important roles of Cr, Co, and Fe in diets. Trace minerals such as Zn, Cu, Mn, and Se are essential with classically defined roles as components of key antioxidant enzymes and proteins. Available evidence indicates that these trace minerals can modulate aspects of oxidative metabolism and immune function in dairy cattle, particularly during the transition period and early lactation. Chromium has been shown to influence both immune function and energy metabolism of cattle; dairy cows fed Cr during the transition period and early lactation have evidence of improved immune function, increased milk production, and decreased cytological endometritis. Factors that complicate trace mineral nutrition at the farm level include the existence of a large number of antagonisms affecting bioavailability of individual trace minerals and uncertainty in terms of requirements under all physiological and management conditions; therefore, determining the optimum level and source of trace minerals under each specific situation continues to be a challenge. Typical factorial approaches to determine requirements for dairy cattle do not account for nuances in biological function observed with supplementation with various forms and amounts of trace minerals. Trace mineral nutrition modulates production, health, and reproduction in cattle although both formal meta-analysis and informal survey of the literature reveal substantial heterogeneity of response in these outcome variables. The industry has largely moved away from oxide-based programs toward sulfate-based programs; however, some evidence favors shifting supplementation strategies further toward more bioavailable forms of inorganic and organic trace

  6. Determination of trace quantities of uranium in rocks mass spectrometric isotope dilution technique

    International Nuclear Information System (INIS)

    Kakazu, Mauricio Hiromitu

    1980-01-01

    A detailed experimental investigation on the thermionic emission of uranium deposited on a single flat type rhenium filament has been carried out. The study was aimed at determining the influence of various forms of deposition on the emission sensitivity and thermal stability of U + , UO + and UO 2 + ions. Based on these investigations, a technique, involving an addition of a small quantity of colloidal suspension of graphite on top of the uranyl nitrate sample deposited, was chosen because of its higher, emission sensitivity for uranium metal ions. The experimental parameters of the technique were optimised and the technique was employed in the determination of trace quantities of uranium in rock samples using mass spectrometric isotope dilution method. For the mass spectrometric isotope dilution analysis National Bureau of Standards uranium isotopic standard NBS-U 970 was employed as a tracer, where as the mass discrimination effect in the uranium isotope analysis was corrected using the uranium isotopic standard NBS-U500. Uranium was determined in each of the seven granite samples from Wyoming, USA and two USGS standard rocks. The precision of the analysis was found to be ±1% . The uranium values obtained on the rock samples were compared with the analyses of other investigators. Influence of the sample splitting on the uranium analysis was discussed in the light of the analytical results obtained.(author)

  7. Determination of trace elements in airborne particulates by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Jung, Yong Sam; Jung, Yung Joo; Jung, Eui Sik; Cho, Seung Yun

    1995-01-01

    Trace elements in airborne particulates were analyzed by instrumental neutron activation analysis(INAA) under the optimum analytical condition. Neutron irradiation for sample was done at the irradiation hole(neutron flux, 1 x 10 13 n/cm 2 s) of TRIGA MARK-III research reactor in the Korea Atomic Energy Research Institute. For the verification of the analytical method, NIST SRM-1648 and NIES CRM No.8 were chosen and analyzed. The accuracy and precision of the analysis of 40 and 24 trace elements in the samples were compared with the certified and reported values, respectively. The analytical method was found to be reliable enough when the analytical data of NIES sample were compared with those of different countries. In the analytical result of two or both of standard reference materials, relative standard deviation was within the 15% except a few elements and the relative error was within the 10%. We used this method to analyze 30 trace elements in airborne particulates collected with the high volume air sampler(PM-10) at two different locations and also confirmed the possibility to use this method as a routine monitoring tool to find out environmental pollution sources. 3 figs., 8 tabs., 19 refs. (Author)

  8. Trace elements determination in Syrian honey using x-ray fluorescence technique

    International Nuclear Information System (INIS)

    Khuder, A.; Ahmad, M.; Saour, G.

    2009-05-01

    Major and trace elements of S, Cl, K, Ca, Ti, Cr, Mn, Fe, Ni, Cu, Zn, Rb, Sr in 27 Syrian honey samples, which collected from different areas in the country, in addition to 3 imported honey samples, were determined by dry ashing method for XRF analysis. The samples were diluted and homogenized with a binder made from cellulose powder. The analyzed elements were divided into three groups, relating to the secondary targets used for X-ray excitation. The internal standard method for XRF analysis with a Mo secondary target was used for the determination of the first group of elements: Sr, Rb, Se, As, Zn, Cu, Ni, and Fe. While, the external standard method for XRF analysis with Cu and Ti secondary targets was used for the determination of the second: Mn, Cr, Ti, Ca, K, and third: Cl, and S group of elements, respectively. The results were accurate with a relative standard error less than 4.2 %. The problem of element loss was overcome by the complete drying of honey samples before their ashing. The moisture content was obtained using mass loss and refractive index methods. As a result, the lower limits of detection (LLD) obtained by Mo-XRF was in the range from 0.011 μg Sr/g to 0.064 μg Fe/g, resulting for samples containing 0.1 % ash and collecting live time 1000 s; while, LLD obtained by Cu-XRF was in the range 0.014 μg Mn/g to 0.057 μg K/g. LLD for S and Cl using Ti secondary target was with values of 0.503 μg/g and 1.96 μg/g, respectively. The enhancement factor obtained by drying method for XRF was in the range from 147 to 1667. Normal concentration of elements in Syrian honey was obtained. The concentration of elements was comparable to those obtained by other workers for honeys in different countries. Elements of K, Ca, and Cl were predominantly distributed in all Syrian honey samples. Elements of Sr, Zn, Cu, Fe, Ti, and S were well distributed in all honey samples. While, the concentrations of Rb, Ni, Mn, Cr elements in some honey samples were below the

  9. Report on the intercomparison run Soil-5 for the determination of trace elements in soil

    Energy Technology Data Exchange (ETDEWEB)

    Dybczynski, R; Tugsavul, A; Suschny, O

    1978-01-01

    he knowledge of the elemental composition of soil, and especially its trace element content is of interest to many investigators active in various fields of research. Among these concerned are not only agricultural chemists and soil scientists, but also biochemists, environmentalists, nutritionists and others. The increased recognition of the essentially on one hand and toxicity on the other, of certain trace elements towards animals and man, has led to intensified studies of the pathways of trace elements in nature, particularly in the environmental research. Not only atmosphere, hydrosphere and biological tissues, but also soil is examined. Essential and toxic trace elements may pass from soil to plants (by which they are sometimes effectively concentrated) and further through food chains to Man. The interest in the analysis of soil for the content of many trace and also some major elements is therefore rapidly increasing. Hence, there seems to be an obvious need for a reference material with established 'recommended values' of as many elements as possible which could be used for checking the quality of analytical work of the laboratories engaged in soil analyses. At the same time well-characterized soil, containing high levels of minerals can be also of interest for geochemists as a complement to already existing geochemical reference samples.

  10. Determination of trace metals in coastal seawater around Okinawa and its multielement profiling analysis

    International Nuclear Information System (INIS)

    Itoh, Akihide; Ishigaki, Teruyuki; Arakaki, Teruo; Yamada, Ayako; Yamaguchi, Mami; Kabe, Noriko

    2009-01-01

    In the present study, trace metals in coastal surface seawater around Okinawa were determined by inductively coupled plasma mass spectrometry (ICP-MS) with chelating disk preconcentration. As a result, the concentrations of V, Mn, Co, Ni, Cu, Zn, Mo, Cd, Pb, and U were obtained in the range from 10 μgL -1 to 0.001 μgL -1 for 6 samples. In addition, multielement profiling analyses were carried out using analytical values obtained in order to elucidate the features of trace metals in each coastal sea area. For coastal surface seawater near an urban area, the analytical values for Zn, Cu, Mn, and Pb were higher by more than 10-fold the literature values for open-surface seawater, and those of Cd were also relatively high. Such a trend concerning the multi-element profile was almost similar to the literature values for coastal seawater of the main island of Japan. On the other hand, the analytical values of most elements for coastal surface seawater near a suburb area were in the range from 0.5 to 5 fold, compared to the literature values for open surface seawater. From multielement profiling analyses for nutrient type elements in marine chemistry, it was suggested that the concentrations of Zn and Cd in a coral sea area normalized to literature values for open surface-seawater were higher than those of Ni and Cu. (author)

  11. Use of Instrumental Neutron Activation Analysis for Determination of Some Trace Elements of Biological Importance in Different Jute(Corchorus Capsularis) Seed Samples

    International Nuclear Information System (INIS)

    Metwally, E.; Abd-El-Khalik, H.; El-Sweify, F.H.; El-Sweify, A.H.H.

    2004-01-01

    Instrumental neutron activation analysis technique was used to determine some trace elements in seeds of jute (corchorus capsularis). The seed samples were obtained from Agricultural Research Center (ARC), Giza, (EG). The analyzed seed samples were produced from cultivation of three different strains, namely: St. DC 1105, st. JRC 7447 and St. PADMA. These strains were imported from Bangladesh. The jute plant was cultivated in sandy soil in Ismailaya research station farm at may on two seasons 1999 and 2000. The plant was irrigated with water from Ismailaya canal. The study was carried out to compare the influence of applying different kinds of fertilizers of different rates, i.e. mineral fertilizer and biofertilizer, on the uptake of some biologically important trace elements and to determine their concentration in the analyzed jute seed samples. These elements were; Co,Cr,Fe,Zn and others eight elements were analyzed quantitatively

  12. Probing Trace-elements in Bitumen by Neutron Activation Analysis

    NARCIS (Netherlands)

    Nahar, S.N.; Schmets, A.J.M.; Scarpas, Athanasios

    Trace elements and their concentrations play an important role in both chemical and physical properties of bitumen. Instrumental Neutron Activation Analysis (INAA) has been applied to determine the concentration of trace elements in bitumen. This method requires irradiation of the material with

  13. Spectrophotometric determination of trace uranium in phosphate ore samples from kurum and uro areas, Nuba mountains, Sudan

    International Nuclear Information System (INIS)

    Mohamed, A. A.; Ali, A. H.; Altayeb, M. A. H.

    2004-01-01

    A method was proposed for the spectrophotometric determination of uranium content in phosphate ores. the method is based on the use of nitrogen (v) acid for leaching the rock, and treatment with ammonium carbonate solution, whereby uranium (Vi) is kept in solution as its carbonate complex. The ion-exchange technique was used for the recovery of uranium. Uranium was determined spectrophotometrically by measurement of the absorbance of the yellow uranium (Vi)-8-hydroxyquinolate complex at λ 425 nm. The procedure was used for the determination of trace uranium content in 30 phosphate ore samples collected from Kurun and Uro areas in Nuba mountains in Sudan. X-ray fluorescence technique was employed for the assessment of the method used. The spectrophotometric method results show a high similarity with those obtained by XRF technique. This agreement indicates that the procedure proposed here has been successfully applied for the determination of uranium in phosphate ores. (Author)

  14. Application of neutron activation analysis to biological materials. Pt. 4. Approach to simultaneous determination of trace elements in human eye tissues with non-destructive neutron activation analysis

    Energy Technology Data Exchange (ETDEWEB)

    Yamaguchi, T; Bando, M; Nakajima, A [Juntendo Univ., Tokyo (Japan). School of Medicine; Terai, M [Tokyo Metropolitan Univ. (Japan). Faculty of Science; Suzuki-Yasumoto, M [National Inst. of Radiological Sciences, Chiba (Japan)

    1980-01-01

    Fourteen trace elements (short-lived nuclides: Al, Br, Cu, Mn and V; long-lived nuclides: Ag, Au, Cd, Co, Cr, Fe, Sc, Se and Zn) in human eye tissues are determined simultaneously by non-destructive neutron activation analysis. The quantity of Al, Br, Fe, Se and Zn in the eye tissues (about 1 to more than 10 ..mu..g/g dry weight tissue) seems to be higher than that of other trace elements, although the content of each trace element in individual tissue is scattered in a wide range. Conjunctiva, iris (+ciliary body) and choroid (+pigment epithelium) seem to contain larger amount of various trace elements than other eye tissues. From correlation studies it is evident that the relative distribution of 14 trace elements in various eye tissues are similar, and furthermore the content of trace elements in the eye tissues may be correlated in each of the three groups (group A: Cd, Se and Zn; group B: Al, Cr, Fe, Se and V; group C: Al, Au, Fe and Se).

  15. A new atomization cell for trace metal determinations by tungsten coil atomic spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Donati, G.L., E-mail: georgedonati@yahoo.com.br [Department of Chemistry, Wake Forest University, Winston-Salem, NC 27109 (United States); Wildman, R.B.; Jones, B.T. [Department of Chemistry, Wake Forest University, Winston-Salem, NC 27109 (United States)

    2011-02-28

    A new metallic atomization cell is used for trace metal determinations by tungsten coil atomic absorption spectrometry and tungsten coil atomic emission spectrometry. Different protecting gas mixtures are evaluated to improve atomic emission signals. Ar, N{sub 2}, CO{sub 2} and He are used as solvents, and H{sub 2} and C{sub 2}H{sub 2} as solutes. A H{sub 2}/Ar mixture provided the best results. Parameters such as protecting gas flow rate and atomization current are also optimized. The optimal conditions are used to determine the figures of merit for both methods and the results are compared with values found in the literature. The new cell provides a better control of the radiation reaching the detector and a small, more isothermal environment around the atomizer. A more concentrated atomic cloud and a smaller background signal result in lower limits of detection using both methods. Cu (324.7 nm), Cd (228.8 nm) and Sn (286.3 nm) determined by tungsten coil atomic absorption spectrometry presented limits of detection as low as 0.6, 0.1, and 2.2 {mu}g L{sup -1}, respectively. For Cr (425.4 nm), Eu (459.4 nm) and Sr (460.7 nm) determined by tungsten coil atomic emission spectrometry, limits of detection of 4.5, 2.5, and 0.1 {mu}g L{sup -1} were calculated. The method is used to determine Cu, Cd, Cr and Sr in a water standard reference material. Results for Cu, Cd and Cr presented no significant difference from reported values in a 95% confidence level. For Sr, a 113% recovery was obtained.

  16. Trace metal speciation: Finally, correctly addressing trace metal issues

    International Nuclear Information System (INIS)

    Donard, O.F.X.

    2001-01-01

    The history of the development of trace metal speciation was discussed and the reasons behind the relatively slow widespread acceptance of its importance were presented. Partially, this was due to the lack of availability of commercial instrumentation and partly to the drive towards improving sensitivity in analytical chemistry which had focused attention on total concentration determinations. The sophistication and control of analytical instrumentation is now such that the spotlight must be turned onto the chemical species of an element present in a sample since this is what governs its behaviour in the biosphere. Indeed, several companies are currently considering the introduction of instrumentation specifically designed for metal species determination

  17. Numerical method of identification of an unknown source term in a heat equation

    Directory of Open Access Journals (Sweden)

    Fatullayev Afet Golayo?lu

    2002-01-01

    Full Text Available A numerical procedure for an inverse problem of identification of an unknown source in a heat equation is presented. Approach of proposed method is to approximate unknown function by polygons linear pieces which are determined consecutively from the solution of minimization problem based on the overspecified data. Numerical examples are presented.

  18. IBA and ICP-OES determination of trace elements in indigenous medicinal herbs and their extracts on the infertility in the human male reproductive system

    Energy Technology Data Exchange (ETDEWEB)

    Mars, J.A.; Fisher, D.; Henkel, R. [Department of Medical Bioscience, Universily of the Weslern Cape, Bellville (South Africa); Weilz, F. [Department of Biodiversily and Conservation Biology, University of the Weslern Cape, Bellville (South Africa)

    2013-07-01

    Full text: The abnormality of infertility in humans is biologically defined (Mader, 2004; Wood, 1994; Ellison, 2001) as the inability of a species to reproduce its own kind after period of 12 month of unprotected sexual intercourse/copulation. It is however difficult when one wishes to quantify the occurrence of infertility, since it is seldom expressed explicitly, but mostly in conjunction with population growth dynamics which include socio-economic factors. Various plants (herbs) have been used as treatment for infertility. These plants however have not yet been scientifically analysed. In this paper we determined the major and trace element composition of Typha capensis (rhizome and leaves) Cissampe/os capensis (Ieaves) and Hermannia cilliata, which were sourced from the Cape Flats Nature Reserve, Bellville, Western Cape Province, South Africa. The trace element concentration determination are at time cumbersome, especially when destructive analytical methods such as ICP-OES are used. For our determination, the various samples were freeze-dried. Part of the freeze-dried sample was used for ICP-OES and the other for PIXE analysis. For PIXE the dried sample was pressed into a pellet, then coated with a layer of carbon and irradiated with a 3 MeV proton beam. We report on the trace element content of the various parts of the plant and comment on the applicability of the part in male infertility. (author)

  19. IBA and ICP-OES determination of trace elements in indigenous medicinal herbs and their extracts on the infertility in the human male reproductive system

    International Nuclear Information System (INIS)

    Mars, J.A.; Fisher, D.; Henkel, R.; Weilz, F.

    2013-01-01

    Full text: The abnormality of infertility in humans is biologically defined (Mader, 2004; Wood, 1994; Ellison, 2001) as the inability of a species to reproduce its own kind after period of 12 month of unprotected sexual intercourse/copulation. It is however difficult when one wishes to quantify the occurrence of infertility, since it is seldom expressed explicitly, but mostly in conjunction with population growth dynamics which include socio-economic factors. Various plants (herbs) have been used as treatment for infertility. These plants however have not yet been scientifically analysed. In this paper we determined the major and trace element composition of Typha capensis (rhizome and leaves) Cissampe/os capensis (Ieaves) and Hermannia cilliata, which were sourced from the Cape Flats Nature Reserve, Bellville, Western Cape Province, South Africa. The trace element concentration determination are at time cumbersome, especially when destructive analytical methods such as ICP-OES are used. For our determination, the various samples were freeze-dried. Part of the freeze-dried sample was used for ICP-OES and the other for PIXE analysis. For PIXE the dried sample was pressed into a pellet, then coated with a layer of carbon and irradiated with a 3 MeV proton beam. We report on the trace element content of the various parts of the plant and comment on the applicability of the part in male infertility. (author)

  20. Identifiability and Identification of Trace Continuous Pollutant Source

    Directory of Open Access Journals (Sweden)

    Hongquan Qu

    2014-01-01

    Full Text Available Accidental pollution events often threaten people’s health and lives, and a pollutant source is very necessary so that prompt remedial actions can be taken. In this paper, a trace continuous pollutant source identification method is developed to identify a sudden continuous emission pollutant source in an enclosed space. The location probability model is set up firstly, and then the identification method is realized by searching a global optimal objective value of the location probability. In order to discuss the identifiability performance of the presented method, a conception of a synergy degree of velocity fields is presented in order to quantitatively analyze the impact of velocity field on the identification performance. Based on this conception, some simulation cases were conducted. The application conditions of this method are obtained according to the simulation studies. In order to verify the presented method, we designed an experiment and identified an unknown source appearing in the experimental space. The result showed that the method can identify a sudden trace continuous source when the studied situation satisfies the application conditions.

  1. Simultaneous determination of macronutrients, micronutrients and trace elements in mineral fertilizers by inductively coupled plasma optical emission spectrometry

    International Nuclear Information System (INIS)

    Oliveira Souza, Sidnei de; Silvério Lopes da Costa, Silvânio; Santos, Dayane Melo; Santos Pinto, Jéssica dos; Garcia, Carlos Alexandre Borges

    2014-01-01

    An analytical method for simultaneous determination of macronutrients (Ca, Mg, Na and P), micronutrients (Cu, Fe, Mn and Zn) and trace elements (Al, As, Cd, Pb and V) in mineral fertilizers was optimized. Two-level full factorial design was applied to evaluate the optimal proportions of reagents used in the sample digestion on hot plate. A Doehlert design for two variables was used to evaluate the operating conditions of the inductively coupled plasma optical emission spectrometer in order to accomplish the simultaneous determination of the analyte concentrations. The limits of quantification (LOQs) ranged from 2.0 mg kg −1 for Mn to 77.3 mg kg −1 for P. The accuracy and precision of the proposed method were evaluated by analysis of standard reference materials (SRMs) of Western phosphate rock (NIST 694), Florida phosphate rock (NIST 120C) and Trace elements in multi-nutrient fertilizer (NIST 695), considered to be adequate for simultaneous determination. Twenty-one samples of mineral fertilizers collected in Sergipe State, Brazil, were analyzed. For all samples, the As, Ca, Cd and Pb concentrations were below the LOQ values of the analytical method. For As, Cd and Pb the obtained LOQ values were below the maximum limit allowed by the Brazilian Ministry of Agriculture, Livestock and Food Supply (Ministério da Agricultura, Pecuária e Abastecimento — MAPA). The optimized method presented good accuracy and was effectively applied to quantitative simultaneous determination of the analytes in mineral fertilizers by inductively coupled plasma optical emission spectrometry (ICP OES). - Highlights: • Determination of inorganic constituents in mineral fertilizers was proposed. • Experimental design methodology was used to optimize analytical method. • The sample preparation procedure using diluted reagents (HNO 3 and H 2 O 2 ) was employed. • The analytical method was satisfactorily to the determination of thirteen elements. • The ICP OES technique can be

  2. Simultaneous determination of macronutrients, micronutrients and trace elements in mineral fertilizers by inductively coupled plasma optical emission spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira Souza, Sidnei de [Laboratório de Química Analítica Ambiental (LQA), Departamento de Química, Centro de Ciências Exatas e Tecnologia, Universidade Federal de Sergipe (UFS), 49100-000, São Cristovão, SE (Brazil); Silvério Lopes da Costa, Silvânio [Laboratório de Química Analítica Ambiental (LQA), Departamento de Química, Centro de Ciências Exatas e Tecnologia, Universidade Federal de Sergipe (UFS), 49100-000, São Cristovão, SE (Brazil); Coordenação de Química, Universidade Federal de Alagoas (UFAL), Campus Arapiraca, 57309-005, Arapiraca, AL (Brazil); Santos, Dayane Melo; Santos Pinto, Jéssica dos; Garcia, Carlos Alexandre Borges [Laboratório de Química Analítica Ambiental (LQA), Departamento de Química, Centro de Ciências Exatas e Tecnologia, Universidade Federal de Sergipe (UFS), 49100-000, São Cristovão, SE (Brazil); and others

    2014-06-01

    An analytical method for simultaneous determination of macronutrients (Ca, Mg, Na and P), micronutrients (Cu, Fe, Mn and Zn) and trace elements (Al, As, Cd, Pb and V) in mineral fertilizers was optimized. Two-level full factorial design was applied to evaluate the optimal proportions of reagents used in the sample digestion on hot plate. A Doehlert design for two variables was used to evaluate the operating conditions of the inductively coupled plasma optical emission spectrometer in order to accomplish the simultaneous determination of the analyte concentrations. The limits of quantification (LOQs) ranged from 2.0 mg kg{sup −1} for Mn to 77.3 mg kg{sup −1} for P. The accuracy and precision of the proposed method were evaluated by analysis of standard reference materials (SRMs) of Western phosphate rock (NIST 694), Florida phosphate rock (NIST 120C) and Trace elements in multi-nutrient fertilizer (NIST 695), considered to be adequate for simultaneous determination. Twenty-one samples of mineral fertilizers collected in Sergipe State, Brazil, were analyzed. For all samples, the As, Ca, Cd and Pb concentrations were below the LOQ values of the analytical method. For As, Cd and Pb the obtained LOQ values were below the maximum limit allowed by the Brazilian Ministry of Agriculture, Livestock and Food Supply (Ministério da Agricultura, Pecuária e Abastecimento — MAPA). The optimized method presented good accuracy and was effectively applied to quantitative simultaneous determination of the analytes in mineral fertilizers by inductively coupled plasma optical emission spectrometry (ICP OES). - Highlights: • Determination of inorganic constituents in mineral fertilizers was proposed. • Experimental design methodology was used to optimize analytical method. • The sample preparation procedure using diluted reagents (HNO{sub 3} and H{sub 2}O{sub 2}) was employed. • The analytical method was satisfactorily to the determination of thirteen elements. • The

  3. Electrochemical preconcentration and hydride generation methods for trace determination of selenium by atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Bye, R.

    1986-01-01

    The use of atomic absorption spectrometry in combination with two different preconcentration/separation techniques for the determination of trace concentrations of selenium is described. Electrochemical preconcentration onto a platinum electrode with a subsequent atomization of selenium is discussed briefly. Several parameters are considered such as the presence of depolarizers, and the temperature of the electrolyzed solutions. Special attention is payed to the efficiency of the atomization step, and a method to improve this is proposed. Applications of the technique to real samples are also reported. Secondly, the separation of the selenium as the volatile selenium hydride from the sample solution is considered. Several papers in this thesis deal with commonly occurring interferants as nickel and copper and with ways of minimizing or avoiding the interferring effects, whereas other papers relate to more theoretical aspects of the hydride generation process. New methods for the determination of selenium in technical samples with high contents of nickel and copper are also presented

  4. Liquid-Liquid Extraction and Determination of Trace Elements in Iron Minerals by Atomic Absorption Spectrometry

    International Nuclear Information System (INIS)

    Taseska, Milena; Stafilov, Trajche; Makreski, Petre; Jacimovic, Radojko; Jovanovski, Gligor

    2006-01-01

    Various trace elements (cadmium, chromium, cobalt, nickel, manganese) in some iron minerals were determined by flame (FAAS) and electrothermal atomic absorption spectrometry (ETAAS). The studied minerals were chalcopyrite (CuFeS 2 ), hematite (Fe 2 O 3 ) and pyrite (FeS 2 ). To avoid the interference of iron, a method for liquid-liquid extraction of iron and determination of investigated elements in the inorganic phase was proposed. Iron was extracted by diisopropyl ether in hydrochloride acid solution and the extraction method was optimized. Some parameters were obtained to be significantly important: Fe mass in the sample should not exceed 0.3 g, the optimal concentration of HCI should be 7.8 mol 1 -1 and ratio of the inorganic and organic phase should be 1: 1. The procedure was verified by the method of standard additions and by its applications to reference standard samples. The investigated minerals originate from various mines in the Republic of Macedonia. (Author)

  5. Particle induced X-ray emission and complementary nuclear methods for trace element determination; Plenary lecture

    Energy Technology Data Exchange (ETDEWEB)

    Johansson, S A.E. [Lund Univ. (Sweden). Dept. of Nuclear Physics

    1992-03-01

    In this review the state-of-the-art of particle induced X-ray emission (PIXE) methods for the determination of trace elements is described. The developmental work has mostly been carried out in nuclear physics laboratories, where accelerators are available, but now the increased interest has led to the establishment of other dedicated PIXE facilities. The reason for this interest is the versatility, high sensitivity and multi-element capability of PIXE analysis. A further very important advantage is that PIXE can be combined with the microbeam technique, which makes elemental mapping with a spatial resolution of about 1 {mu}m possible. As a technique, PIXE can also be combined with other nuclear reactions such as elastic scattering and particle-induced gamma emission, so that light elements can be determined. The usefulness of PIXE is illustrated by a number of typical applications in biology, medicine, geology, air pollution research, archaeology and the arts. (author).

  6. Trace determinations of individual organic pollutants - 25 years of research at the Swiss Federal Institute for Environmental Science and Technology (EAWAG)

    Energy Technology Data Exchange (ETDEWEB)

    Giger, W. [Swiss Federal Inst. for Environmental Science and Technology (EAWAG), Duebendorf (Switzerland)

    1997-12-01

    An overview is given on analytical developments and applications for the determination of organic trace pollutants which have been performed at EAWAG since 1972. Gas and liquid chromatographic methods are of crucial importance. The presented examples include environmental hydrocarbons, semivolatile compounds and detergent-derived chemicals. (author) 4 figs., 1 tab., 6 refs.

  7. Determination of Mineral, Trace Element, and Pesticide Levels in Honey Samples Originating from Different Regions of Malaysia Compared to Manuka Honey

    Science.gov (United States)

    Moniruzzaman, Mohammed; Chowdhury, Muhammed Alamgir Zaman; Rahman, Mohammad Abdur; Sulaiman, Siti Amrah; Gan, Siew Hua

    2014-01-01

    The present study was undertaken to determine the content of six minerals, five trace elements, and ten pesticide residues in honeys originating from different regions of Malaysia. Calcium (Ca), magnesium (Mg), iron (Fe), and zinc (Zn) were analyzed by flame atomic absorption spectrometry (FAAS), while sodium (Na) and potassium (K) were analyzed by flame emission spectrometry (FAES). Trace elements such as arsenic (As), lead (Pb), cadmium (Cd), copper (Cu), and cobalt (Co) were analyzed by graphite furnace atomic absorption spectrometry (GFAAS) following the microwave digestion of honey. High mineral contents were observed in the investigated honeys with K, Na, Ca, and Fe being the most abundant elements (mean concentrations of 1349.34, 236.80, 183.67, and 162.31 mg/kg, resp.). The concentrations of the trace elements were within the recommended limits, indicating that the honeys were of good quality. Principal component analysis reveals good discrimination between the different honey samples. The pesticide analysis for the presence of organophosphorus and carbamates was performed by high performance liquid chromatography (HPLC). No pesticide residues were detected in any of the investigated honey samples, indicating that the honeys were pure. Our study reveals that Malaysian honeys are rich sources of minerals with trace elements present within permissible limits and that they are free from pesticide contamination. PMID:24982869

  8. Determination of Mineral, Trace Element, and Pesticide Levels in Honey Samples Originating from Different Regions of Malaysia Compared to Manuka Honey

    Directory of Open Access Journals (Sweden)

    Mohammed Moniruzzaman

    2014-01-01

    Full Text Available The present study was undertaken to determine the content of six minerals, five trace elements, and ten pesticide residues in honeys originating from different regions of Malaysia. Calcium (Ca, magnesium (Mg, iron (Fe, and zinc (Zn were analyzed by flame atomic absorption spectrometry (FAAS, while sodium (Na and potassium (K were analyzed by flame emission spectrometry (FAES. Trace elements such as arsenic (As, lead (Pb, cadmium (Cd, copper (Cu, and cobalt (Co were analyzed by graphite furnace atomic absorption spectrometry (GFAAS following the microwave digestion of honey. High mineral contents were observed in the investigated honeys with K, Na, Ca, and Fe being the most abundant elements (mean concentrations of 1349.34, 236.80, 183.67, and 162.31 mg/kg, resp.. The concentrations of the trace elements were within the recommended limits, indicating that the honeys were of good quality. Principal component analysis reveals good discrimination between the different honey samples. The pesticide analysis for the presence of organophosphorus and carbamates was performed by high performance liquid chromatography (HPLC. No pesticide residues were detected in any of the investigated honey samples, indicating that the honeys were pure. Our study reveals that Malaysian honeys are rich sources of minerals with trace elements present within permissible limits and that they are free from pesticide contamination.

  9. Microwave assisted digestion of atmospheric aerosol samples followed by inductively coupled plasma mass spectrometry determination of trace elements

    Energy Technology Data Exchange (ETDEWEB)

    Swami, K.; Judd, C.D.; Orsini, J.; Yang, K.X. [New York State Dept. of Health, Albany, NY (United States). Wadsworth Center for Labs. and Research; Husain, L. [New York State Dept. of Health, Albany, NY (United States). Wadsworth Center for Labs. and Research; Dept. of Environmental Health and Toxicology, State Univ. of New York, Albany (United States)

    2001-01-01

    A microwave digestion method in a closed vessel was developed for the determination of trace metals in atmospheric aerosols using inductively coupled plasma mass spectrometry (ICP-MS). A recovery study for the elements V, Cr, Mn, Fe, Co, Ni, Cu, Zn, As, Se, Cd, Sb, and Pb was conducted using multi-elemental standard solutions, NIST 1633b Trace Elements in Coal Fly Ash, and NIST 1648 Urban Particulate Matter. A simple digestion method using only HNO{sub 3}/H{sub 2}O{sub 2}gave good recoveries (90%-108%) for all elements except Cr in SRM 1648, but yielded low recoveries for SRM 1633b. A more robust method using HNO {sub 3}/H {sub 2}O {sub 2}/HF/H {sub 3}BO {sub 3} yielded higher recoveries (82%-103%) for the lighter elements (V - Zn) in SRM 1633b, and improved the Cr recovery in SRM 1648, but decreased the Se recovery in both SRMs. A comparative analysis of aerosol samples obtained at a remote mountain location Nathiagali, Pakistan (2.5 km above mean sea level), and Mayville, New York, downwind from the highly industrialized Midwestern United States, was carried out using Instrumental Neutron Activation Analysis (INAA) for the elements Cr, Mn, Fe, Co, Zn, As, Se, and Sb. The simple digestion method yielded excellent agreement for Cr, Fe, Zn, As, Se, and Sb, with slopes of the ICP-MS vs. INAA regressions of 0.90-1.00 and R {sup 2} values of 0.96-1.00. The regressions for Mn and Co had slopes of 0.82 and 0.84 with R {sup 2} values of 0.83 and 0.82, respectively. Addition of HF/H {sub 3}BO {sub 3} did not improve the correlation for any of the elements and degraded the precision somewhat. The technique provides sensitivity and accuracy for trace elements in relatively small aerosol samples used in atmospheric chemistry studies related to SO {sub 2} oxidation in cloud droplets. The ability to determine concentrations of a very large number of elements from a single analysis will permit source apportionment of various trace pollutants and hence strategies to control the

  10. Trace quantities of uranium in some indian chewing tobaccos as determined by fission track analysis

    International Nuclear Information System (INIS)

    Rana, N.P.S.; Singh, P.; Azam, A.; Naqvi, A.H.; Srivastava, D.S.

    1996-01-01

    The sandwiched pellet technique using Makrofol-E plastic track detectors has been employed to determine trace quantities of uranium in nine brands of flavored chewing tobaccos consumed by the Indian population. In this technique the nuclear reaction, 235 U(n,f), is used for the quantitative estimation of uranium. The maximum value of uranium (1.88 ppm) has been found in raw tobacco leaves (Surti), while the minimum (0.13 ppm) in Tulsi (Double Zero brand). Other seven brands showed intermediate values of U-contents which are also reported in this paper. These values are compared with the U-contents reported in the literature for other forms of tobaccos. (author). 9 refs., 2 figs., 1 tab

  11. Studies on the determination of trace amounts of nitrogen along with alkali and alkaline earth elements in uranium based samples by ion-chromatography (IC)

    International Nuclear Information System (INIS)

    Verma, Poonam; Rastogi, R.K.; Ramakumar, K.L.

    2006-12-01

    Present report describes an ion chromatography (IC) method with suppressed conductivity detection for the determination of traces of nitrogen along with alkali and alkaline earth elements in uranium based nuclear fuels. Method was developed to determine nitrogen as NH 4 + along with alkali and alkaline earth cations by IC using a cation exchange column. (author)

  12. Multiple analysis of an unknown optical multilayer coating

    International Nuclear Information System (INIS)

    Dobrowolski, J.A.; Ho, F.C.; Waldorf, A.

    1985-01-01

    Results are given of the analysis at five different laboratories of an unknown optical multilayer coating. In all, eleven different analytical and laboratory techniques were applied to the problem. The multilayer nominally consisted of three dielectric and two metallic layers. It was demonstrated convincingly that with present day techniques it is possible to determine the basic structure of such a coating

  13. Determination of trace elements in the reproduction systems of some rare animals using pixe

    Science.gov (United States)

    Suqing, Chen; Nengming, Wang; Jianxuan, Chen; Dazhong, Zhang

    In order to search for the significance of artificial feeding, reproduction and heredity, trace elements in the reproductive systems of some rare animals, including giant panda, lesser panda, marmot and river deer, have been determined. Typcial X-ray spectra of various samples are given. The elemental contents in ovary and testis of the giant panda and the lesser panda are calculated by means of yttrium as an internal standard. Elemental relative concentrations are calculated from peak areas in the spectra for thick samples. It is found that for the concentration of the elements Cr, Mn, Fe, Ni, Cu, As in the ovary there exist no significant different between the giant panda and the lesser panda. The concentration of Zn, however, shows a remakable difference. The importance of zinc in biological processes is discussed.

  14. Cell-selective determination of trace elements in testis by SR-XRF analysis with nanoprobe

    International Nuclear Information System (INIS)

    Homma-Takeda, Shino; Nishimura, Yoshikazu; Watanabe, Yoshito; Yukawa, Masae; Ueno, Shunji; Terada, Yasuko

    2005-01-01

    Organotin compounds are widely used in industry and its environmental contamination by these compounds has recently become a concern. It is known that they act as endocrine disruptors but details of the dynamics of Sn in reproductive organs are still unknown. In the present study, we attempted to determine Sn in the testis of rats exposed to tributyltin chloride (TBTC) cell-selectively by synchrotron radiation X-ray florescence analysis with nanoprobe. TBTC was orally administered to rats at a dose of 45 μmol/kg per day for 3 days. One day later, Sn was detected in spermatozoa at the stage VIII seminiferous tubule, which are the final step of spermatogenesis in the testis. Sn levels in the microdissectioned seminiferous tubules determined by inductively coupled argon plasma-mass spectrometry were approximately equivalent to that in the testis. These data indicate that Sn accumulates in germ cells as well as in spermatozoa in a short period of TBTC exposure. (author)

  15. Trace elements in precious and common opals using neutron activation analysis

    International Nuclear Information System (INIS)

    McOrist, G.D.; Smallwood, A.

    1997-01-01

    Neutron activation analysis (NAA) was used to determine the concentration of trace elements in 44 precious and 52 common opals sampled from a number of recognised fields within Australia. The purpose of this study was to determine if precious and common opals of the same colour and location have the same or a different trace element profile. Similar numbers of black, white and grey samples were studied in each case. In most cases, common opals had a significantly higher concentration of certain trace elements when compared with precious opals. (author)

  16. Rapid determination of benzene derivatives in water samples by trace volume solvent DLLME prior to GC-FID

    Energy Technology Data Exchange (ETDEWEB)

    Diao, Chun Peng; Wei, Chao Hai; Feng, Chun Hua [South China Univ. of Technology, Guangzhou Higher Education Mega Center (China). College of Environmental Science and Engineering; Guangdong Regular Higher Education Institutions, Guangzhou (China). Key Lab. of Environmental Protection and Eco-Remediation

    2012-05-15

    An inexpensive, simple and environmentally friendly method based on dispersive liquid liquid microextraction (DLLME) for rapid determination of benzene derivatives in water samples was proposed. A significant improvement of DLLME procedure was achieved. Trace volume ethyl acetate (60 {mu}L) was exploited as dispersion solvent instead of common ones such as methanol and acetone, the volume of which was more than 0.5 mL, and the organic solvent required in DLLME was reduced to a great extent. Only 83-{mu}L organic solvent was consumed in the whole analytic process and the preconcentration procedure was less than 10 min. The advantageous approach coupled with gas chromatograph-flame ionization detector was proposed for the rapid determination of benzene, toluene, ethylbenzene and xylene isomers in water samples. Results showed that the proposed approach was an efficient method for rapid determination of benzene derivatives in aqueous samples. (orig.)

  17. Designing towards the unknown

    DEFF Research Database (Denmark)

    Wilde, Danielle; Underwood, Jenny

    2018-01-01

    the research potential to far-ranging possibilities. In this article we unpack the motivations driving the PKI project. We present our mixed-methodology, which entangles textile crafts, design interactions and materiality to shape an embodied enquiry. Our research outcomes are procedural and methodological......New materials with new capabilities demand new ways of approaching design. Destabilising existing methods is crucial to develop new methods. Yet, radical destabilisation—where outcomes remain unknown long enough that new discoveries become possible—is not easy in technology design where complex......, to design towards unknown outcomes, using unknown materials. The impossibility of this task is proving as useful as it is disruptive. At its most potent, it is destabilising expectations, aesthetics and processes. Keeping the researchers, collaborators and participants in a state of unknowing, is opening...

  18. Recension: Mao - The Unknown Story

    DEFF Research Database (Denmark)

    Clausen, Søren

    2005-01-01

    Anmeldelse - kritisk! - til Sveriges førende Kinatidsskrift af Jung Chang & Jon Halliday's sensationelle "Mao - the Unknown Story".......Anmeldelse - kritisk! - til Sveriges førende Kinatidsskrift af Jung Chang & Jon Halliday's sensationelle "Mao - the Unknown Story"....

  19. Evaluating cleansing effects on trace elements and stable isotope values in feathers of oiled birds.

    Science.gov (United States)

    Valladares, Sonia; Moreno, Roćio; Jover, Lluis; Sanpera, Carola

    2010-01-01

    Feathers of seabirds are widely used as a nondestructive tissue for pollution monitoring of trace elements, as well as convenient samples for trophic ecology studies by means of stable isotope analysis (SIA). Nevertheless, feathers can be occasionally impregnated with oil from deliberate ship discharges and from massive oil spill accidents. The feather structure makes them effective traps for particles and are subject to external contamination. It is unknown to what extent the oil adhered to feathers can change trace element concentrations or stable isotope signatures. This study has two primary objectives: (1) to assess if there are differences between trace element concentrations and stable isotope signatures of oiled and clean feathers, and (2) to determine if the cleansing of oiled feathers using commonly applied techniques such as sodium hydroxide (NaOH) washes in combination with an organic solvent (hexane) is more effective than using NaOH alone. In order to do this, we analysed trace elements (Se, Hg, Pb, Cu and Zn) and stable isotopes (delta(13)C and delta(15)N) of individual feathers of yellow-legged gulls (Larus michahellis) which were affected by the 2002 Prestige oil spill in Galicia (NW Spain). Two sets of feathers were analysed, one group were oil-free (Control group) and the other had oil adhered to its surface (Oiled group). We expected to find differences between control and oiled feathers when cleaning exclusively with NaOH and no differences when using hexane. Our results did not show significant differences between Control and Oiled groups as a consequence of the cleansing method used. Unexpectedly, the additional cleansing with hexane resulted in decreasing selenium concentrations and increasing zinc and delta(15)N values in all groups of feathers.

  20. Carcinoma of Unknown Primary Treatment (PDQ®)—Health Professional Version

    Science.gov (United States)

    Carcinoma of unknown primary (CUP) treatment depends on the best determination of the primary site, if possible. Treatment options may include surgery, radiation therapy, and systemic treatment. Get detailed information about diagnosis and treatment of CUP in this summary for clinicians.

  1. Preparation of tracing source layer in simulation test of nuclide migration

    International Nuclear Information System (INIS)

    Zhao Yingjie; Ni Shiwei; Li Weijuan; Yamamoto, T.; Tanaka, T.; Komiya, T.

    1993-01-01

    In cooperative research between CIRP and JAERI on safety assessment for shallow land disposal of low level radioactive waste, a laboratory simulation test of nuclide migration was carried out, in which the undisturbed loess soil column sampled from CIRP' s field test site was used as testing material, three nuclides, Sr-85, Cs-137 and Co-60 were used as tracers. Special experiment on tracing method was carried out, which included measuring pH value of quartz sand in HCl solution, determining the eligible water content of quartz sand as tracer carrier, measuring distribution uniformity of nuclides in the tracing quartz sand, determining elution rate of nuclides from the tracing quartz sand and detecting activity uniformity of tracing source layer. The experiment results showed that the tracing source layer, in which fine quartz sand was used as tracer carrier, satisfied expected requirement. (1 fig.)

  2. Analysis of trace elements in opal using PIXE

    Energy Technology Data Exchange (ETDEWEB)

    Hinrichs, Ruth, E-mail: ruth.hinrichs@ufrgs.br [Instituto de Geociências, Universidade Federal do Rio Grande do Sul, Porto Alegre, RS (Brazil); Programa de Pós-graduação em Física, UFRGS, Porto Alegre, RS (Brazil); Bertol, A.P.L. [Programa de Pós-graduação em Física, UFRGS, Porto Alegre, RS (Brazil); Vasconcellos, M.A.Z. [Programa de Pós-graduação em Física, UFRGS, Porto Alegre, RS (Brazil); Instituto de Física, UFRGS, Porto Alegre, RS (Brazil)

    2015-11-15

    Particle induced X-ray emission (PIXE) analysis is particularly important for the analysis of trace elements of precious samples, being one of the few methods to determine elements with ppm concentration that does not affect sample integrity. A PIXE methodology for trace element analysis in opal was developed. To avoid detector count saturation due to the high number of Si-Kα X-rays generated in the sample, several filters were employed to optimize the reduction of the Si-Kα signal, while maintaining acceptable intensities of the other relevant X-ray lines. Two proton beam energies were tested, to establish the signal to noise ratio in different X-ray energies. Spectra were fitted with the software GUPIX, using a matrix composition determined with electron beam excited energy dispersive X-ray spectrometry. Above the energy of the silicon X-ray, several trace elements were quantified.

  3. Determination of trace level anions in reactor cooling water by ion chromatography using a resin of low capacity

    International Nuclear Information System (INIS)

    1988-01-01

    In the field of nuclear technology, IC has been found to be one of the most versatile and efficient analytical technique because of its ability to provide a fast and sensitive analysis of anions. In this work, a separater column packed with a resin of very low capacity was used with a concentration column for the determination of low level of anions present as traces in reactor cooling water. The results of retention times and detection limits were determined using 2.4 mM Na2CO3 / 3mM NaHCO3 mixture as eluent. The interferences of cations and anions such as (Ca)2+, (UO2)2+, (SO4)2+, have been investigated

  4. Macro-Elements and Trace Elements in Cereal Grains Cultivated in Latvia

    Directory of Open Access Journals (Sweden)

    Jākobsone Ida

    2015-09-01

    Full Text Available Cereal-based foods have great importance in the compensation of micro- and trace element deficiency, because 50% of the foods produced worldwide are made up of cereal grains. The aim of the research was to determine the concentration of macro-elements and trace elements in different cereals cultivated in Latvia. Various cereals were used in the research: rye (n = 45, barley (n = 54, spring wheat (n = 27, winter wheat (n = 53, triticale (n = 45 and oats (n = 42. Thirteen macro- and trace elements (Cd, Pb, Ni, Cr, Al, Cu, K, Na, Mn, Fe, Zn, Mg, Ca were determined in cereal grain samples (n = 266. Macro-elements and trace elements varied significantly (p < 0.01 or p < 0.001. The highest concentrations of macro- and trace elements were found in oats and the lowest in rye. The obtained data will expand the opportunity for food and nutrition scientists to evaluate content of the examined elements in grain products, and dietary consumption (bioavailability of the examined macro-elements and trace elements.

  5. Molecular Speciation of Trace Metal Organic Complexes in the Pacific Ocean

    Science.gov (United States)

    Repeta, D.; Boiteau, R. M.; Bundy, R. M.; Babcock-Adams, L.

    2017-12-01

    Microbial production across approximately one third of the surface ocean is limited by extraordinarily low (picomolar) concentrations of dissolved iron, essentially all of which is complexed to strong organic ligands of unknown composition. Other biologically important trace metals (cobalt, copper, zinc, nickel) are also complexed to strong organic ligands, which again have not been extensively characterized. Nevertheless, organic ligands exert a strong influence on metal bioavailability and toxicity. For example, amendment experiments using commercially available siderophores, organic compounds synthesized by microbes to facilitate iron uptake, show these ligands can both facilitate or impede iron uptake depending on the siderophore composition and available uptake pathways. Over the past few years we have developed analytical techniques using high pressure liquid chromatography interfaced with inductively coupled plasma and electrospray ionization mass spectrometry to identify and quantify trace metal organic complexes in laboratory cultures of marine microbes and in seawater. We found siderophores to be widely distributed in the ocean, particularly in regions characterized by low iron concentrations. We also find chemically distinct complexes of copper, zinc, colbalt and nickel that we have yet to fully characterize. We will discuss some of our recent work on trace metal organic speciation in seawater and laboratory cultures, and outline future efforts to better understand the microbial cycling of trace metal organic complexes in the sea.

  6. Application of chronocoulomentry for trace levels uranium determination using catalytic nitrate reduction on mercury electrode

    International Nuclear Information System (INIS)

    Cantagallo, M.I.C.

    1988-01-01

    With the aim of improving the sensitivity of the electro-analytical determination of uranium at trace levels, the uranium catalyzed reduction of nitrate on mercury electrodes was used and the technique of chronocoulometry was compared with other voltammetric techniques. The catalytic process offers high sensitivity in comparison with uranyl reduction in absence of nitrate. The chronocoulometry, virtually unexplored for analytical applications, was found to be specially well suited for determinations based on this kind of electrode process, when using current integration times in the range of several seconds. Under these conditions the interference from diffusion controlled faradaic processes is reduced to a minimum. Several experimental parameters were investigated (eletrolyte composition, potential program, integration time, blank correction, temperature, previous separation) and adequate conditions were selected for the analytical determination of pure and real samples. The proposed method was applied and evaluated with real and, when necessary, an adapted liquid-liquid extraction procedure was used. Reference materials with complex matrices like rocks were first solubilized by hot digestion under pressure. The obtained results are in good agreement with the values obtained with other techniques such as X-ray fluorescence, mass spectrometry-isotope dilution and epithermal netron activation analysis. (author) [pt

  7. Determining trace element in hair of children with mental retardation

    International Nuclear Information System (INIS)

    Wang Zhilan; Gu Bomei; Jia Meixiang

    1992-01-01

    Seven trace elements in the hair come from 29 mental retardation children and 29 normal children have been analysed by INAA and XRF. There are significant differences for Fe and Sc between the two groups. The average value of Pb in the hair of the mental retardation children is higher than that of the normal children. Although Zn is very important for children growing, there is no significant difference between two children groups

  8. Quantification and localization of trace metals in natural plankton using a synchrotron x-ray fluorescence microprobe

    International Nuclear Information System (INIS)

    Twining, B. S.; Baines, S. B.; Fisher, N. S.; Jacobsen, C.; Maser, J.; State Univ. of New York at Stony Brook

    2003-01-01

    The accumulation of trace metals by planktonic protists influences the growth of primary producers, metal biogeochemical cycling, and metal bioaccumulation in aquatic food chains. Despite their importance, unequivocal measurements of trace element concentrations in individual plankton cells have not been possible to date. We have used the 2-ID-E side-branch hard x-ray microprobe at the Advanced Photon Source to measure trace elements in individual marine plankton cells. This microprobe employs zoneplate optics to produce the sub-micron spatial resolution and low background fluorescence required to produce trace element maps of planktonic protist cells ranging in size from 3 to >50 (micro)m. We have developed preservation, rinsing, and mounting protocols that remove most of the salt from our marine samples, thus simplifying the identification of unknown cells and reducing high Cl-related background fluorescence. We have also developed spectral modeling techniques that account for the frequent overlap of adjacent fluorescence peaks and non-uniform detector response. Finally, we have used parallel soft x-ray transmission and epifluorescence microscopy images to estimate C normalized trace element concentrations, identify functional cell types (e.g., photosynthetic vs. non-photosynthetic), and correlate cell structures with spatial patterns in trace element fluorescence

  9. Quantification and localization of trace metals in natural plancton using a synchrotron x-ray fluorescence microprobe.

    Energy Technology Data Exchange (ETDEWEB)

    Twining, B. S.; Baines, S. B.; Fisher, N. S.; Jacobsen, C.; Maser, J.; State Univ. of New York at Stony Brook

    2003-03-01

    The accumulation of trace metals by planktonic protists influences the growth of primary producers, metal biogeochemical cycling, and metal bioaccumulation in aquatic food chains. Despite their importance, unequivocal measurements of trace element concentrations in individual plankton cells have not been possible to date. We have used the 2-ID-E side-branch hard x-ray microprobe at the Advanced Photon Source to measure trace elements in individual marine plankton cells. This microprobe employs zoneplate optics to produce the sub-micron spatial resolution and low background fluorescence required to produce trace element maps of planktonic protist cells ranging in size from 3 to >50 {micro}m. We have developed preservation, rinsing, and mounting protocols that remove most of the salt from our marine samples, thus simplifying the identification of unknown cells and reducing high Cl-related background fluorescence. We have also developed spectral modeling techniques that account for the frequent overlap of adjacent fluorescence peaks and non-uniform detector response. Finally, we have used parallel soft x-ray transmission and epifluorescence microscopy images to estimate C normalized trace element concentrations, identify functional cell types (e.g., photosynthetic vs. non-photosynthetic), and correlate cell structures with spatial patterns in trace element fluorescence.

  10. Trace amount analysis using spark mass spectrometry

    International Nuclear Information System (INIS)

    Stefani, Rene

    1975-01-01

    Characteristics of spark mass spectrometers (ion source, properties of the ion beam, ion optics, and performance) and their use in qualitative and quantitative analysis are described. This technique is very interesting for the semi-quantitative analysis of trace amounts, down to 10 -8 atoms. Examples of applications such as the analysis of high purity materials and non-conducting mineral samples, and determination of carbon and gas trace amounts are presented. (50 references) [fr

  11. Adsorptive stripping voltammetric determination of trace amounts of lead in environmental water samples with complicated matrix

    Directory of Open Access Journals (Sweden)

    Grabarczyk M.

    2013-04-01

    Full Text Available A sensitive, simple and fast adsorptive stripping voltammetric procedure for trace determination of lead in environmental water samples has been developed. The method is based on adsorptive accumulation of the Pb(II-cupferron complex onto a hanging mercury drop electrode, followed by the reduction of the adsorbed species by a voltammetric scan using differential pulse modulation. The interference from surface active substances was eliminated by adsorption of interferents onto an Amberlite XAD-16 resin. Optimumconditions for removing the surfactants by mixing the analysed sample with resin were evaluated. The accuracy of the method was tested by analyzing certified reference material (SPS-WW1 Waste Water.

  12. Determination of trace elements in various kinds of bean by X-ray spectrometric techniques (1995-96)

    International Nuclear Information System (INIS)

    U Tin Maung Kyi; U Wai Zin Oo

    2001-01-01

    Various kinds of bean such as Peanut, Gram Whole, Black Eye Bean, Small Red Bean, Lab Lab Bean, Green Mung Bean, Filed Pea, Seasame Seed, Sultani, Maize, Butter Bean, Dolichos Lab Lab, Toor Whole, Small Yellow Bean, Cow Pea have been collected and analysed by EDXRF analysis for trace elements. The measurement system consists of a Cd-109 annual excitation source, a Si (Li) detector, H V power supply, a spectrometry amplifier, a multichannel analyser and a personal computer. The samples were prepared as pressed pellets and measured by Emission Transmission Technique. The accuracy was determined by analysing standard reference material, SOIL-7 form IAEA. (author)

  13. Determination of trace element concentration in infant head hair of Rawalpindi/Islamabad area using INAA technique

    International Nuclear Information System (INIS)

    Zaidi, J.H.; Gill, K.P.

    2004-01-01

    The concentration of 18 minor and trace elements (essential, toxic and nonessential) in infant head hair was determined. The data provide the base-line values of these elements in head hair of infants of low- and medium-income group subjects. The statistical results show that there are significant correlations between some elements such as: Ca-Zn, Ca-Fe, Mg-Ca, Mg-Mn and Mg-Fe. The results obtained have been compared with the data reported in the literature. Our data show compatibility of elemental contents of infant head hair with those from some of the other geological regions but also deviate in some cases. (orig.)

  14. Neutron activation analysis for environmental trace element research determination of elemental composition of sediments in the Sea of Galillee, Israel

    Energy Technology Data Exchange (ETDEWEB)

    Lavi, N; Ne` eman, E; Brenner, S; Butenko, V [Tel Aviv Univ. (Israel). Medical School

    1996-12-01

    The aims of this work were to: a) demonstrate the effectiveness of instrumental neutron activation analysis for determining the background concentrations of trace elements in the sediments collected from the Sea of Gallile. b) determine the advantage factors for epithermal neutron irradiation. c) determine the contribution of silicon to the total {sup 28}Al activity by the {sup 28}Si(n,p){sup 28}Al reaction. c) check the validity of the method by determining the elemental content of U.S. NBS Standard Reference Material SRM-1633a (fly ash). d) calculate the average enrichment factors for the elements in sediments . e) determine the concentrations of the artificial radionuclides {sup 134}Cs, {sup 137}Cs and the naturally occurring radionuclides {sup 40}K, {sup 226}Ra and {sup 232}Th (authors).

  15. Consumer perception of Brazilian traced beef

    Directory of Open Access Journals (Sweden)

    Júlio Otávio Jardim Barcellos

    2012-03-01

    Full Text Available The objective of this study was to determine consumers understanding of beef traceability, identifying how consumers value this meat and traceability elements to be presented on retail shelves. The method used in this study was a survey through the internet applying the Sphinx software. The sample consisted of 417 consumers, mostly living in Porto Alegre, Brazil. Consumers are aware of certified beef, consider it important, but this is not a demand. As to traced beef, most consumers (62.4% are in favor of mandatory traceability of beef cattle in Brazil, but 86.6% disagree with the destination of traced beef only to the foreign market. The majority of people are willing to pay more for traced beef and consider traceability a market opportunity, used as a differentiating tool.

  16. Determination of several trace elements in silicate rocks by an XRF method with background and matrix corrections

    International Nuclear Information System (INIS)

    Pascual, J.

    1987-01-01

    An X-ray fluorescence method for determining trace elements in silicate rock samples was studied. The procedure focused on the application of the pertinent matrix corrections. Either the Compton peak or the reciprocal of the mass absorption coefficient of the sample was used as internal standard for this purpose. X-ray tubes with W or Cr anodes were employed, and the W Lβ and Cr Kα Compton intensities scattered by the sample were measured. The mass absorption coefficients at both sides of the absorption edge for Fe (1.658 and 1.936 A) were calculated. The elements Zr, Y, Rb, Zn, Ni, Cr and V were determined in 15 international reference rocks covering wide ranges of concentration. Relative mean errors were in many cases less than 10%. (author)

  17. Determination of thallium at ultra-trace levels in water and biological samples using solid phase spectrophotometry.

    Science.gov (United States)

    Amin, Alaa S; El-Sharjawy, Abdel-Azeem M; Kassem, Mohammed A

    2013-06-01

    A new simple, very sensitive, selective and accurate procedure for the determination of trace amounts of thallium(III) by solid-phase spectrophotometry (SPS) has been developed. The procedure is based on fixation of Tl(III) as quinalizarin ion associate on a styrene-divinylbenzene anion-exchange resin. The absorbance of resin sorbed Tl(III) ion associate is measured directly at 636 and 830 nm. Thallium(I) was determined by difference measurements after oxidation of Tl(I) to Tl(III) with bromine. Calibration is linear over the range 0.5-12.0 μg L(-1) of Tl(III) with relative standard deviation (RSD) of 1.40% (n=10). The detection and quantification limits are 150 and 495 ng L(-1) using 0.6 g of the exchanger. The molar absorptivity and Sandell sensitivity are also calculated and found to be 1.31×10(7) L mol(-1)cm(-1) and 0.00156 ng cm(-2), respectively. The proposed procedure has been successfully applied to determine thallium in water, urine and serum samples. Copyright © 2013 Elsevier B.V. All rights reserved.

  18. Determination of thallium at ultra-trace levels in water and biological samples using solid phase spectrophotometry

    Science.gov (United States)

    Amin, Alaa S.; El-Sharjawy, Abdel-Azeem M.; Kassem, Mohammed A.

    2013-06-01

    A new simple, very sensitive, selective and accurate procedure for the determination of trace amounts of thallium(III) by solid-phase spectrophotometry (SPS) has been developed. The procedure is based on fixation of Tl(III) as quinalizarin ion associate on a styrene-divinylbenzene anion-exchange resin. The absorbance of resin sorbed Tl(III) ion associate is measured directly at 636 and 830 nm. Thallium(I) was determined by difference measurements after oxidation of Tl(I) to Tl(III) with bromine. Calibration is linear over the range 0.5-12.0 μg L-1 of Tl(III) with relative standard deviation (RSD) of 1.40% (n = 10). The detection and quantification limits are 150 and 495 ng L-1 using 0.6 g of the exchanger. The molar absorptivity and Sandell sensitivity are also calculated and found to be 1.31 × 107 L mol-1 cm-1 and 0.00156 ng cm-2, respectively. The proposed procedure has been successfully applied to determine thallium in water, urine and serum samples.

  19. Determination of Tetracycline and Fluoroquinolone Antibiotics at Trace Levels in Sludge and Soil

    Directory of Open Access Journals (Sweden)

    Marie-Virginie Salvia

    2015-01-01

    Full Text Available This work describes the development of a sensitive analytical method to determine simultaneously traces of tetracycline and fluoroquinolone antibiotics in sludge and soil, based on PLE extraction, followed by SPE purification and finally an analysis by LC-MS/MS. Recoveries were greater than 87% in the case of fluoroquinolones and between 25.4 and 41.7% for tetracyclines. Low relative standard deviations (<15% were obtained in both matrices. The limits of quantification were comprised between 1.1 and 4.6 ng/g and between 5 and 20 ng/g in soil and sludge, respectively. The method was then successfully applied to the analysis of the target antibiotics in sludge as well as soil that received spreading. The substances most frequently found and with the highest levels were fluoroquinolones with concentrations exceeding 1,000 ng/g in several samples of sludge and up to 16 ng/g in soil.

  20. Determination of trace amounts of cerium in silicate rocks based on its candoluminescence in a calcium oxide based matrix

    International Nuclear Information System (INIS)

    Belcher, R.; Nasser, T.A.K.; Polo-Diez, L.; Townshend, A.

    1977-01-01

    A very sensitive method for the determination of cerium (above 10 ng ml -1 ) has been developed (Belcher et al., Analyst;100:415(1975)), based on the measurement of the green candoluminescence produced by cerium in a calcium oxide-calcium sulphate matrix, with sulphuric acid as a coactivator, when the matrix is inserted into a hydrogen-nitrogen-air flame. This paper describes the application of this method to the determination of trace amounts of cerium in rocks. It involves the fusion of the sample with lithium metaborate, and does not require the isolation of cerium from other components of the rock, before measuring the candoluminescence intensity of the cerium. (author)

  1. Determination of trace element concentrations and stable lead, uranium and thorium isotope ratios by quadrupole-ICP-MS in NORM and NORM-polluted sample leachates

    Energy Technology Data Exchange (ETDEWEB)

    Mas, J.L., E-mail: ppmasb@us.es [Dpto. Fisica Aplicada I, EPS, Universidad de Sevilla, 41012 Sevilla (Spain); Villa, M. [Servicio de Radioisotopos, Centro de Investigacion, Tecnologia e Innovacion (CITIUS), Universidad de Sevilla, Avda. Reina Mercedes 4b, 41012 Sevilla (Spain); Dpto. Fisica Aplicada II, ETS de Arquitectura, Universidad de Sevilla, Avda. Reina Mercedes 2, 41012 Sevilla (Spain); Hurtado, S. [Servicio de Radioisotopos, Centro de Investigacion, Tecnologia e Innovacion (CITIUS), Universidad de Sevilla, Avda. Reina Mercedes 4b, 41012 Sevilla (Spain); Garcia-Tenorio, R. [Dpto. Fisica Aplicada II, ETS de Arquitectura, Universidad de Sevilla, Avda. Reina Mercedes 2, 41012 Sevilla (Spain)

    2012-02-29

    Highlights: Black-Right-Pointing-Pointer Polluted sediment and NORM samples. Black-Right-Pointing-Pointer An efficient yet fast process allowing multi-parametric determinations in <3 days. Black-Right-Pointing-Pointer Trace element concentrations, Pb, Th and U isotope ratios with a single instrument. - Abstract: This work focuses on the monitoring of the potential pollution in scenarios that involve NORM-related industrial activities (environmental or in-door scenarios). The objective was to develop a method to determine extent and origin of the contamination, suitable for monitoring (i.e. simple, fast and economical) and avoiding the use of too many different instruments. It is presented a radiochemical method that allows the determination of trace element concentrations and {sup 206}Pb/{sup 207}Pb/{sup 208}Pb, {sup 238}U/{sup 234}U and {sup 232}Th/{sup 230}Th isotope ratios using a single sample aliquot and a single instrument (ICP-QMS). Eichrom UTEVA{sup Registered-Sign} extraction chromatography minicolumns were used to separate uranium and thorium in sample leachates. Independent ICP-MS determinations of uranium and thorium isotope ratios were carried out afterwards. Previously a small aliquot of the leachate was used for the determination of trace element concentrations and lead isotope ratios. Several radiochemical arrangements were tested to get maximum performances and simplicity of the method. The performances of the method were studied in terms of chemical yields of uranium and thorium and removal of the potentially interfering elements. The established method was applied to samples from a chemical industry and sediments collected in a NORM-polluted scenario. The results obtained from our method allowed us to infer not only the extent, but also the sources of the contamination in the area.

  2. Trace element analysis in soy sauce

    International Nuclear Information System (INIS)

    Haruyama, Yoichi; Saito, Manabu; Tomiya, Michio

    1993-01-01

    Trace elements in soy sauce have been measured by means of in-air PIXE. Six kinds of trace elements were detected, such as Mn, Fe, Ni, Zn, Cu and Br. Concentrations of Mn, Fe, Zn and Br which were observed in all samples, have been determined. Each analyzed sample contained considerable amount of Br about 160 ppm. Comparison of Br content of the imported raw materials with those of the domestic ones suggested that the large amount of Br was the residual fumigation chemicals in the imported raw materials. (author)

  3. The determination of a neutron source position in an unknown homogeneous medium: The planar case

    International Nuclear Information System (INIS)

    Dubinski, S.; Talmor, A.; Presler, O.; Tshuva, A.; Yaar, I.; Orion, I.; Alfassi, Z.B.

    2005-01-01

    The possibility of localization of an unknown neutron source in various bulky homogeneous media (box) was studied. For the planar case, two 3 He detectors on the opposite faces of the box were used. A constant polypropylene shield around the box and detectors was used to eliminate the varying contribution from the environment to increase count rates of the detectors and to protect the experimentalist. It is shown that the location of a single small neutron emitting source in a large box can be found to a better than 7% by using two neutron detectors positioned on parallel faces of the box, coplanar with the source. The localization requires measurement of the count rate of both the unknown source and an extra source positioned on one of the faces of the box. The localization is based on the finding that the ratio of the count rates of the two detectors is an exponential function of the distance of the source from one of the detectors

  4. Determination of trace element and heavy metal in black tea and tea leaves using x-ray fluorescence

    International Nuclear Information System (INIS)

    Salih, Mohamed Abualgasim Abdalhakam

    2016-08-01

    The aim of this study was to provide information about the trace element and heavy metals concentrations in black tea and tea leaves. 23 different samples were collected from the Sudanese local market. The collected samples were characterized as the most common used items in Sudan. The concentration of trace and heavy elements were determined using x-ray fluorescence (X RF) technique. The standard reference materials (IAEA-V-10) and hay (powder) were used to evaluate the accuracy of the analytical result. The measured values were found in agreement with the certified values. The elements determined were K, Ca, Cr, Mn, Fe, Ni, Cu, Zn, Pb, Br, Rb, and Sr. The average concentration of the elements is black tea were 2277.43, 7245.71, 1.11, 1025.29, 334.29, 6.88, 11.24, 9.47, 1.02, 7.08, 97.4 and 63.21 respectively while the average concentration of the elements in leaves tea were 2644.44, 8805.56, 1.02, 571.81, 295.44, 6.19, 10.69, 9.26, 0.91, 13.42, 63.03 and 67.14 respectively. The results showed an increase in the concentration of some elements such as calcium, chromium, manganese, iron, nickel, copper, zinc, bromine, rubidium and strontium (22500, 6.75, 48.9, 194, 4.37, 9,77, 24.9, 8.23, 7.79, 40,9) ppm respectively compared to certified values. Correlation between concentration of certain element and cluster analysis were preformed and the results compared with values of literature and the concentrations of some elements found to be similar.(Author)

  5. The catalytic kinetic method for the determination of trace formaldehyde (FA) base on a bromate-eosin Y system

    Science.gov (United States)

    Tang, Yufang; Chen, Hao; Weng, Chao; Tang, Xiaohui; Zhang, Miaoling; Yang, Qiongqiong; Hu, Tao; Cai, Changqun

    A new simple and highly sensitive catalytic kinetic method for the determination of trace amount of FA in food sample has been established. The method was based on the catalytic effect of FA on the oxidation of eosin Y by potassium bromate in present of phosphoric acid. The reaction was monitored spectrophotometrically by measuring the decrease in absorbance of eosin Y at 518 nm. Under the optimized experimental conditions, the developed method allowed the determination of FA in the range of 0.03-0.6 μg mL-1 with a good precision, and the limit of detection was down to 0.00988 μg mL-1. The relative standard deviation of five replicate measurements for the determination of FA in concentration 0.12 μg mL-1 was 1.8%. The proposed method was successfully applied to the determination of FA in food directly and satisfactory results were obtained.

  6. Determination of trace elements in tea leaves by neutron activation analysis

    International Nuclear Information System (INIS)

    Kasrai, M.; Shoushtarian, M.J.; Bozorgzadeh, M.H.

    1977-01-01

    Instrumental neutron-activation analysis has been employed to determine 14 trace elements in two brands of Iranian and foreign tea. A popular local brand (Ghoncheh) and a foreign brand (Lipton tea bags) were randomly purchased. The samples were dried in an oven (100 deg C) and used without further treatment. In order to measure the concentration of elements in tea solution, weighed amounts of tea were mixed with double-distilled boiling water. After cooling the leaves were separated by centrifugation. Aliquots of clear solution were dried for analysis. Three sets of standards containing the following elements using the spec-pure materials were prepared: (a) Cl, Mn, Na, K; (b) Br, La, Au; (c) Cr, Fe, Rb, Sc, Cs, Zn, Co. In each irradiation, one set of standards, along with the sample, was neutron irradiated at a thermal flux of approximately 2x10 13 ncm -2 sec -1 in the Research Reactor of the Nuclear Research Centre. The period of irradiation ranged from 10 min to 4 hrs, depending on the radionuclides to be measured. The transference ratio of the elements into solution, when tea is leached by percolation, is also reported. It was found that some elements are totally transferred into solution and some are partially retained by the leaves. (T.G.)

  7. Determination of rare-earths and other trace elements in neo proterozoic-neo paleozoic dykes from Ceara state, Brazil, by neutron activation analysis

    Energy Technology Data Exchange (ETDEWEB)

    Anjos, Rafael Martins dos; Figueiredo, Ana M.G., E-mail: rafael.anjos@usp.b, E-mail: anamaria@ipen.b [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil). Centro do Reator Nuclear de Pesquisas. Lab. de Analise por Ativacao com Neutrons; Cardoso, Gustavo Luan; Marques, Leila S., E-mail: leila@iag.usp.b [Universidade de Sao Paulo (IAG/USP), SP (Brazil). Inst. de Astronomia, Geofisica e Ciencias Atmosfericas

    2011-07-01

    Trace elements such as rare earths, U, Th, Ta, Ba and Hf can be very useful in petrogenetic studies of igneous and metamorphic rocks, giving information about the origin and evolution of magmas. Instrumental Neutron Activation Analysis (INAA) is an accurate and precise for trace element analysis in geological samples, and provides the information required for this kind of studies. In this study, rare earths and incompatible trace elements were determined by INAA in the geological reference materials GS-N and BE-N, to quality control, and for the investigation of acid dykes of neo proterozoic-neo paleozoic ages, which outcrop in the Medio Coreau and Ceara Central domains from the Borborema Province (Ceara State). The powdered samples (particle sizes less than 100 mesh), crushed by using a mechanical agate mortar grinder, were irradiated at the IEA-R1 nuclear reactor at IPEN-CNEN/SP, and the induced activity was measured by high resolution gamma-ray spectrometry. The accuracy and precision of the method were evaluated and preliminary results of dyke samples are presented. (author)

  8. Fast grasping of unknown objects using principal component analysis

    Science.gov (United States)

    Lei, Qujiang; Chen, Guangming; Wisse, Martijn

    2017-09-01

    Fast grasping of unknown objects has crucial impact on the efficiency of robot manipulation especially subjected to unfamiliar environments. In order to accelerate grasping speed of unknown objects, principal component analysis is utilized to direct the grasping process. In particular, a single-view partial point cloud is constructed and grasp candidates are allocated along the principal axis. Force balance optimization is employed to analyze possible graspable areas. The obtained graspable area with the minimal resultant force is the best zone for the final grasping execution. It is shown that an unknown object can be more quickly grasped provided that the component analysis principle axis is determined using single-view partial point cloud. To cope with the grasp uncertainty, robot motion is assisted to obtain a new viewpoint. Virtual exploration and experimental tests are carried out to verify this fast gasping algorithm. Both simulation and experimental tests demonstrated excellent performances based on the results of grasping a series of unknown objects. To minimize the grasping uncertainty, the merits of the robot hardware with two 3D cameras can be utilized to suffice the partial point cloud. As a result of utilizing the robot hardware, the grasping reliance is highly enhanced. Therefore, this research demonstrates practical significance for increasing grasping speed and thus increasing robot efficiency under unpredictable environments.

  9. [Unification of methods for determining the trace quantities of lead, zinc, sodium and potassium ions in the assessment of drinking water adn transfusion fluid quality].

    Science.gov (United States)

    Popkov, V A; Golovina, N V; Evgrafov, A A

    2001-01-01

    The results of long-term studies made by the Department of General Chemistry, I. M. Sechenov Moscow Medical Academy, that deals with unification of methods for determining some ions of metals (lead, zinc, sodium, and potassium) in the assessment of the quality of drinking water and transfusion fluids are summarized. A procedure was developed to determine the trace impurities of zinc, lead, and silver by atomic absorption spectrometry (AAS) by using sorption concentration. C-80-2-aminothiazole, a new sorbent synthesized at the Research Institute of Polymers, was used to detect these ions in the drinking water. With regards to the chosen optimal conditions, drinking water samples were analyzed via their direct spraying in the air-acetylene flame. The prior sorption concentration determined drinking water zinc and lead ions in the concentrations equal to or less than their permissible dose concentrations. The studies indicated that the used methods to determine the trace quantities of metals in the drinking water and aqueous solutions show a high sensitivity, rapidity, simplicity of sample preparation.

  10. Trace elements determinations in cancerous and non-cancerous human tissues using instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Choi, Insup.

    1989-01-01

    Recent improvements in analyzing techniques when coupled to the growing knowledge of trace element biochemistry provide a powerful tool to investigate the relationship between trace elements and cancer. It is hoped that selective delivery or restriction of specific minerals may aid in cancer prevention or treatment. Tissues were collected at the time of surgery of various cancer patients including colon cancer and breast cancer. Three kinds of tissues were taken from a patient; cancerous, noncancerous, and transitional tissue obtained from a region located between the cancer and healthy tissues. A total of 57 tissues were obtained from 19 cancer patients. Seven of them were colon cancer patients, and 5 of them were breast cancer patients. Nine elements were determined using instrumental activation analysis. Cancerous colon tissue had significantly higher concentrations of selenium and iron than healthy tissues. Cancerous breast tissue had significantly higher concentrations of selenium, iron, manganese, and rubidium than healthy tissues. Iron can be enriched in cancer tissue because cancer tissue retains more blood vessels. Selenium is enriched in cancer tissue, possibly in an effort of the body to inhibit the growth of tumors. The manganese enrichment can be explained in the same manner as selenium considering its suspected anticarcinogenicity. It is not certain why rubidium was enriched in cancer tissue. It could be that this is the result of alteration of cell membrane permeability, change in extracellular matrix, or increased metabolism in cancer tissue

  11. Study on the application of electrothermal atomization atomic absorption spectrometry for the determination of metallic Cu, Pb, Zn, Cd traces in sea water samples

    International Nuclear Information System (INIS)

    Nguyen Thi Kim Dung; Doan Thanh Son; Tran Thi Ngoc Diep

    2004-01-01

    The trace amount of some heavy metallic elements (Cu, Zn, Pb, Cd) in sea water samples were determined directly (without separation) and quantitatively by using Electro-Thermal Atomization Atomic Absorption Spectrometry (ETA-AAS). The effect of mainly major constituents such as Na, Mg, Ca, K, and the mutual effect of the trace elements, which were present in the matrix on the absorption intensity of each analyzed element was studied. The adding of a certain chemical modification for each trace element was also investigated in order to eliminate the overall effect of the background during the pyrolysis and atomization. The sea water sample after fitrating through a membrane with 0.45 μm-hole size was injected in to the graphite tube via an autosampler (MPE50). The absorption intensity of each element was then measured on the VARIO-6 under the optimum parameters for spectrometer such as: maximum wavelength, current of hollow cathode lamp, and that for graphite furnace such as dry temperature, pyrolysis temperature, atomization temperature, ect. The analytical procedures were set-up and applied for the determination of these above mentioned elements in the synthesized sea water sample and in the real sea water samples with high precision and accuracy. (author)

  12. A high-throughput solid-phase extraction microchip combined with inductively coupled plasma-mass spectrometry for rapid determination of trace heavy metals in natural water.

    Science.gov (United States)

    Shih, Tsung-Ting; Hsieh, Cheng-Chuan; Luo, Yu-Ting; Su, Yi-An; Chen, Ping-Hung; Chuang, Yu-Chen; Sun, Yuh-Chang

    2016-04-15

    Herein, a hyphenated system combining a high-throughput solid-phase extraction (htSPE) microchip with inductively coupled plasma-mass spectrometry (ICP-MS) for rapid determination of trace heavy metals was developed. Rather than performing multiple analyses in parallel for the enhancement of analytical throughput, we improved the processing speed for individual samples by increasing the operation flow rate during SPE procedures. To this end, an innovative device combining a micromixer and a multi-channeled extraction unit was designed. Furthermore, a programmable valve manifold was used to interface the developed microchip and ICP-MS instrumentation in order to fully automate the system, leading to a dramatic reduction in operation time and human error. Under the optimized operation conditions for the established system, detection limits of 1.64-42.54 ng L(-1) for the analyte ions were achieved. Validation procedures demonstrated that the developed method could be satisfactorily applied to the determination of trace heavy metals in natural water. Each analysis could be readily accomplished within just 186 s using the established system. This represents, to the best of our knowledge, an unprecedented speed for the analysis of trace heavy metal ions. Copyright © 2016 Elsevier B.V. All rights reserved.

  13. Determination of trace elements of Egyptian crops by neutron activation analysis. Pt. 3. Trace elements in African tea, ginger, canella bark, black pepper, sesame, lady's fingers, jew's mallow, tomatos, cucumber and marrow

    Energy Technology Data Exchange (ETDEWEB)

    Sherif, M K; Awadallah, R M; Amrallah, A H [Assiut Univ. (Egypt)

    1980-01-01

    Multielemental neutron activation analysis was used for the determination of Al, As, Au, Br, Ca, Cd, Co, Cr, Cu, Fe, La, Mn, Mo, Sb, Se, W and Zn in African tea and lady's fingers (Malvaceae Family), ginger (Zingiperanceae Family), canella bark (Laureceae Family), black pepper (Piperaceae Family), cucumber seeds and vegetable marrow seeds (Cucurbitaceae Family), tomatos seed (Solanaceae Family), safflower seeds (Compositae Family), jew's mallow seed (Tiliaceae Family) and sesame (Pedaliaceae Family). Trace elements determination was made for the analysis of destructive (using super pure nitric acid and adsorbing the metal-APDC and metal-Dz complexes on activated charcoal) and nondestructive (dry seeds) samples. The method is simple, precise and sensitive for the determination of microamounts of the elements (ppM to ppB).

  14. Electroadsorption-assisted direct determination of trace arsenic without interference using transmission X-ray fluorescence spectroscopy.

    Science.gov (United States)

    Jiang, Tian-Jia; Guo, Zheng; Liu, Jin-Huai; Huang, Xing-Jiu

    2015-08-18

    An analytical technique based on electroadsorption and transmission X-ray fluorescence (XRF) for the quantitative determination of arsenic in aqueous solution with ppb-level limits of detection (LOD) is proposed. The approach uses electroadsorption to enhance the sensitivity and LOD of the arsenic XRF response. Amine-functionalized carbonaceous microspheres (NH2-CMSs) are found to be the ideal materials for both the quantitative adsorption of arsenic and XRF analysis due to the basic amine sites on the surface and their noninterference in the XRF spectrum. In electroadsorptive X-ray fluorescence (EA-XRF), arsenic is preconcentrated by a conventional three-electrode system with a positive electricity field around the adsorbents. Then, the quantification of arsenic on the adsorbents is achieved using XRF. The electroadsorption preconcentration can realize the fast transfer of arsenic from the solution to the adsorbents and improve the LOD of conventional XRF compared with directly determining arsenic solution by XRF alone. The sensitivity of 0.09 cnt ppb(-1) is obtained without the interferences from coexisted metal ions in the determination of arsenic, and the LOD is found to be 7 ppb, which is lower than the arsenic guideline value of 10 ppb given by the World Health Organization (WHO). These results demonstrated that XRF coupled with electroadsorption was able to determine trace arsenic in real water sample.

  15. Computer compensation for NMR quantitative analysis of trace components

    International Nuclear Information System (INIS)

    Nakayama, T.; Fujiwara, Y.

    1981-01-01

    A computer program has been written that determines trace components and separates overlapping components in multicomponent NMR spectra. This program uses the Lorentzian curve as a theoretical curve of NMR spectra. The coefficients of the Lorentzian are determined by the method of least squares. Systematic errors such as baseline/phase distortion are compensated and random errors are smoothed by taking moving averages, so that there processes contribute substantially to decreasing the accumulation time of spectral data. The accuracy of quantitative analysis of trace components has been improved by two significant figures. This program was applied to determining the abundance of 13C and the saponification degree of PVA

  16. Influence of trace elements in human tissue in low-energy photon brachytherapy dosimetry

    International Nuclear Information System (INIS)

    White, Shane A; Landry, Guillaume; Van Gils, Francis; Verhaegen, Frank; Reniers, Brigitte

    2012-01-01

    The aim of this paper is to determine the dosimetric impact of trace elements in human tissues for low-energy photon sources used in brachytherapy. Monte Carlo dose calculations were used to investigate the dosimetric effect of trace elements present in normal or cancerous human tissues. The effect of individual traces (atomic number Z = 11–30) was studied in soft tissue irradiated by low-energy brachytherapy sources. Three other tissue types (prostate, adipose and mammary gland) were also simulated with varying trace concentrations to quantify the contribution of each trace to the dose distribution. The dose differences between cancerous and healthy prostate tissues were calculated in single- and multi-source geometries. The presence of traces in a tissue produces a difference in the dose distribution that is dependent on Z and the concentration of the trace. Low-Z traces (Na) have a negligible effect ( 3%). There is a potentially significant difference in the dose distribution between cancerous and healthy prostate tissues (4%) and even larger if compared to the trace-free composition (15%) in both single- and multi-sourced geometries. Trace elements have a non-negligible (up to 8% in prostate D 90 ) effect on the dose in tissues irradiated with low-energy photon sources. This study underlines the need for further investigation into accurate determination of the trace composition of tissues associated with low-energy brachytherapy. Alternatively, trace elements could be incorporated as a source of uncertainty in dose calculations. (paper)

  17. Trace element determination in plant material by means of instrumental neutron activation analysis (INAA) with special reference to molybdenum

    International Nuclear Information System (INIS)

    Schnier, C.; Schnug, E.

    1981-01-01

    The instrumental neutron activation analysis (INAA) permits a non-destructive multielement determination of minute trace element concentrations in organic material. No sample preparation except drying is required. Especially for the determination of molybdenum the INAA offers great advantages compared to the methods used in agricultural chemistry where complicated enrichment and extraction steps are needed. Contamination by reagents or loss of elements are not potential sources of errors. The principle, the advantages and disadvantages of INAA are described. The method is demonstrated with the example of celery samples from an experiment with five different nitrogen fertilizers on contaminated soil and of cabbage samples from an uncontaminated region. Besides molybdenum, 19 other elements (Na, K, Ca, Sc, Cr, Fe, Co, Zn, As, Se, Br, Rb, Cd, Sb, Ba, La, W, Au, Th) are determined. (orig.) [de

  18. Relationship between epiphytic lichens, trace elements and gaseous atmospheric pollutants

    NARCIS (Netherlands)

    Dobben, van H.F.; Wamelink, G.W.W.; Braak, ter C.J.F.

    2001-01-01

    A study was conducted to determine the joint effect of gaseous atmospheric pollutants and trace elements on epiphytic lichens. We used our data to test the hypothesis that lichens are generally insensitive to toxic effects of trace elements, and can therefore be used as accumulator organisms to

  19. Combined Application of QEM-SEM and Hard X-ray Microscopy to Determine Mineralogical Associations and Chemcial Speciation of Trace Metals

    Energy Technology Data Exchange (ETDEWEB)

    M Grafe; M Landers; R Tappero; P Austin; B Gan; A Grabsch; C Klauber

    2011-12-31

    We describe the application of quantitative evaluation of mineralogy by scanning electron microscopy in combination with techniques commonly available at hard X-ray microprobes to define the mineralogical environment of a bauxite residue core segment with the more specific aim of determining the speciation of trace metals (e.g., Ti, V, Cr, and Mn) within the mineral matrix. Successful trace metal speciation in heterogeneous matrices, such as those encountered in soils or mineral residues, relies on a combination of techniques including spectroscopy, microscopy, diffraction, and wet chemical and physical experiments. Of substantial interest is the ability to define the mineralogy of a sample to infer redox behavior, pH buffering, and mineral-water interfaces that are likely to interact with trace metals through adsorption, coprecipitation, dissolution, or electron transfer reactions. Quantitative evaluation of mineralogy by scanning electron microscopy coupled with micro-focused X-ray diffraction, micro-X-ray fluorescence, and micro-X-ray absorption near edge structure (mXANES) spectroscopy provided detailed insights into the composition of mineral assemblages and their effect on trace metal speciation during this investigation. In the sample investigated, titanium occurs as poorly ordered ilmenite, as rutile, and is substituted in iron oxides. Manganese's spatial correlation to Ti is closely linked to ilmenite, where it appears to substitute for Fe and Ti in the ilmenite structure based on its mXANES signature. Vanadium is associated with ilmenite and goethite but always assumes the +4 oxidation state, whereas chromium is predominantly in the +3 oxidation state and solely associated with iron oxides (goethite and hematite) and appears to substitute for Fe in the goethite structure.

  20. Development of methods for the neutron activation analysis to the determination of essential and toxic trace elements of biological and environmental samples: application of enzyme activity of raw hides

    International Nuclear Information System (INIS)

    Sipos, T.; Nagy, L.G.; Toeroek, G.; Kollar, J.

    1974-01-01

    Investigations on the post mortem enzymatic processes pointed out the fact, that significant deviations can be observed in the extent and in the results of the autolytic transformations occurring during the storage of raw hide. A neutron activation analysis procedure, based on a semiautomated radiochemical separation procedure and scintillation gamma spectrometry, was selected for the determination of some trace elements. Six trace elements, Cu, Mn, Zn, Au, As, and Cr, and one minor component,Br, were detected and/or determined in the concentration region of 0,1-10 3 ppM. According to preliminary investigations evaluated at the time being, concentration differences of some orders of magnitude were obtained for some trace elements: copper, zinc and manganese, whereas the concentration of bromine remained practically constant. These findings seem to correlate with large differences in appearance due to different enzyme activities in the raw hides

  1. Mathematical considerations regarding the stability of the trace element systems by linear regressions

    International Nuclear Information System (INIS)

    Mihai, Maria; Popescu, I.V.

    2002-01-01

    In this paper we present a mathematical model that would describe the stability and instability conditions, respectively of the organs of human body assumed as a living cybernetic system with feedback. We tested the theoretical model on the following trace elements: Mn, Zn and As. The trace elements were determined from the nose-pharyngeal carcinoma. We utilise the linear approximation to describe the dependencies between the trace elements determined in the hair of the patient. We present the results graphically. (authors)

  2. Determination of refractory trace elements in Chinese meteorites by RNAA

    International Nuclear Information System (INIS)

    Kraehenbuehl, U.; Burger, M.

    1989-01-01

    Some refractory trace elements are important target elements for spallation reactions in meteorites. These elements also serve to characterize the investigated meteorites. The elements Ti, Y, Zr, Hf, W and Ta were measured after radiochemical separation in chondrites from China. After acid digestion of the irradiated samples, the group separations were obtained by precipitation reactions. The necessary radiochemical purification of the pure β emitter Y was realized on a Lewatite OC 1026 column. For all the other elements discrete gamma radiation was measured. (orig.)

  3. TraceContract

    Science.gov (United States)

    Kavelund, Klaus; Barringer, Howard

    2012-01-01

    TraceContract is an API (Application Programming Interface) for trace analysis. A trace is a sequence of events, and can, for example, be generated by a running program, instrumented appropriately to generate events. An event can be any data object. An example of a trace is a log file containing events that a programmer has found important to record during a program execution. Trace - Contract takes as input such a trace together with a specification formulated using the API and reports on any violations of the specification, potentially calling code (reactions) to be executed when violations are detected. The software is developed as an internal DSL (Domain Specific Language) in the Scala programming language. Scala is a relatively new programming language that is specifically convenient for defining such internal DSLs due to a number of language characteristics. This includes Scala s elegant combination of object-oriented and functional programming, a succinct notation, and an advanced type system. The DSL offers a combination of data-parameterized state machines and temporal logic, which is novel. As an extension of Scala, it is a very expressive and convenient log file analysis framework.

  4. Determination of trace amounts of cadmium in sea water by a flameless atomic absorption method

    International Nuclear Information System (INIS)

    Yamazoe, Seigo; Oshima, Shozo

    1975-01-01

    Determination of trace amounts of cadmium in sea water has been developed by a flameless atomic absorption method using a carbon rod atomizer. Sea water is diluted with isopropyl alcohol and the white salt formed is removed by filtration, then the filtrate is fed to the instrument as a sample for measurement. A complete separation of the salt is not needed in this pre-treatment. The effect of the residual salt can be avoided by separating the atomic absorption of cadmium and the molecular absorption of the residual salt by means of controlling the temperature and the time of ashing and atomization of the sample in the carbon rod. The repeatability and the accuracy are 2.0--8.5% in the coefficient of variation and 0.8--5.3% respectively. (auth.)

  5. Determination of trace quaternary ammonium surfactants in water by combining solid-phase extraction with surface-assisted laser desorption/ionization mass spectrometry.

    Science.gov (United States)

    Chen, Y C; Sun, M C

    2001-01-01

    This study demonstrates the feasibility of combining solid-phase extraction (SPE) with surface-assisted laser desorption/ionization (SALDI) mass spectrometry to determine trace quaternary ammonium surfactants in water. The trace surfactants in water were directly concentrated on the surface of activated carbon sorbent in SPE. The activated carbon sorbent was then mixed with the SALDI liquid for SALDI analysis. No SPE elution procedure was necessary. Experimental results indicate that the surfactants with longer chain alkyl groups exhibit higher sensitivities than those with shorter chain alkyl groups in SPE-SALDI analysis. The detection limit for hexadecyltrimethylammonium bromide is around 10 ppt in SPE-SALDI analysis by sampling 100 mL of aqueous solution, while that of tetradecyltrimethylammonium bromide is about 100 ppt. The detection limit for decyltrimethylammonium bromide and dodecyltrimethylammonium bromide is in the low-ppb range. Copyright 2001 John Wiley & Sons, Ltd.

  6. Tracing the origin of glomerular extracapillary lesions from parietal epithelial cells.

    Science.gov (United States)

    Smeets, Bart; Uhlig, Sandra; Fuss, Astrid; Mooren, Fieke; Wetzels, Jack F M; Floege, Jürgen; Moeller, Marcus J

    2009-12-01

    Cellular lesions form in Bowman's space in both crescentic glomerulonephritis and collapsing glomerulopathy. The pathomechanism and origin of the proliferating cells in these lesions are unknown. In this study, we examined proliferating cells by lineage tracing of either podocytes or parietal epithelial cells (PECs) in the nephrotoxic nephritis model of inflammatory crescentic glomerulonephritis. In addition, we traced the fate of genetically labeled PECs in the Thy-1.1 transgenic mouse model of collapsing glomerulopathy. In both models, cellular bridges composed of PECs were observed between Bowman's capsule and the glomerular tuft. Genetically labeled PECs also populated larger, more advanced cellular lesions. In these lesions, we detected de novo expression of CD44 in activated PECs. In contrast, we rarely identified genetically labeled podocytes within the cellular lesions of crescentic glomerulonephritis. In conclusion, PECs constitute the majority of cells that compose early extracapillary proliferative lesions in both crescentic glomerulonephritis and collapsing glomerulopathy, suggesting similar pathomechanisms in both diseases.

  7. Determination of minor and trace elements in kidney stones by x-ray fluorescence analysis

    Science.gov (United States)

    Srivastava, Anjali; Heisinger, Brianne J.; Sinha, Vaibhav; Lee, Hyong-Koo; Liu, Xin; Qu, Mingliang; Duan, Xinhui; Leng, Shuai; McCollough, Cynthia H.

    2014-03-01

    The determination of accurate material composition of a kidney stone is crucial for understanding the formation of the kidney stone as well as for preventive therapeutic strategies. Radiations probing instrumental activation analysis techniques are excellent tools for identification of involved materials present in the kidney stone. In particular, x-ray fluorescence (XRF) can be very useful for the determination of minor and trace materials in the kidney stone. The X-ray fluorescence measurements were performed at the Radiation Measurements and Spectroscopy Laboratory (RMSL) of department of nuclear engineering of Missouri University of Science and Technology and different kidney stones were acquired from the Mayo Clinic, Rochester, Minnesota. Presently, experimental studies in conjunction with analytical techniques were used to determine the exact composition of the kidney stone. A new type of experimental set-up was developed and utilized for XRF analysis of the kidney stone. The correlation of applied radiation source intensity, emission of X-ray spectrum from involving elements and absorption coefficient characteristics were analyzed. To verify the experimental results with analytical calculation, several sets of kidney stones were analyzed using XRF technique. The elements which were identified from this techniques are Silver (Ag), Arsenic (As), Bromine (Br), Chromium (Cr), Copper (Cu), Gallium (Ga), Germanium (Ge), Molybdenum (Mo), Niobium (Nb), Rubidium (Rb), Selenium (Se), Strontium (Sr), Yttrium (Y), Zirconium (Zr). This paper presents a new approach for exact detection of accurate material composition of kidney stone materials using XRF instrumental activation analysis technique.

  8. Simultaneous spectrophotometric determination of trace copper, nickel, and cobalt ions in water samples using solid phase extraction coupled with partial least squares approaches

    Science.gov (United States)

    Guo, Yugao; Zhao, He; Han, Yelin; Liu, Xia; Guan, Shan; Zhang, Qingyin; Bian, Xihui

    2017-02-01

    A simultaneous spectrophotometric determination method for trace heavy metal ions based on solid-phase extraction coupled with partial least squares approaches was developed. In the proposed method, trace metal ions in aqueous samples were adsorbed by cation exchange fibers and desorbed by acidic solution from the fibers. After the ion preconcentration process, the enriched solution was detected by ultraviolet and visible spectrophotometer (UV-Vis). Then, the concentration of heavy metal ions were quantified by analyzing ultraviolet and visible spectrum with the help of partial least squares (PLS) approaches. Under the optimal conditions of operation time, flow rate and detection parameters, the overlapped absorption peaks of mixed ions were obtained. The experimental data showed that the concentration, which can be calculated through chemometrics method, of each metal ion increased significantly. The heavy metal ions can be enriched more than 80-fold. The limits of detection (LOD) for the target analytes of copper ions (Cu2 +), cobalt ions (Co2 +) and nickel ions (Ni2 +) mixture was 0.10 μg L- 1, 0.15 μg L- 1 and 0.13 μg L- 1, respectively. The relative standard deviations (RSD) were less than 5%. The performance of the solid-phase extraction can enrich the ions efficiently and the combined method of spectrophotometric detection and PLS can evaluate the ions concentration accurately. The work proposed here is an interesting and promising attempt for the trace ions determination in water samples and will have much more applied field.

  9. Determination of metal traces in lubricating oils by Aas and Icp-SFMS after microwave digestion

    International Nuclear Information System (INIS)

    Perez B, M. A.; Acosta L, C. E.; Hernandez M, H.; Romero G, E. T.; Lara A, N.; Kuri C, A.

    2016-09-01

    The analysis of lubricating oils allows to monitor the operating conditions of the machines and equipment, their pollution levels, degradation and finally their wear and useful life, as well as to establish a preventive lubrication program as a technical diagnostic maintenance tool. The useful life of oil is the period of functional time has in the machine until the antioxidants are consumed, producing large changes in the physical (density and viscosity) and chemical properties of the base oil, resulting in a wear of the components that make up the machine. The present work includes a theoretical as well as analytical basis for determining the content of metallic elements (Ag, Al, Cu, Fe, Mg, Sn and Zn) at trace level in used lubricating oils. A simple and rapid method of analysis is proposed, consisting mainly of the pretreatment of the sample by acidic digestion with a microwave oven. Subsequently an open digestion in a heating plate is carried out to dryness and recovered with concentrated HNO 3 . For the quantitative analysis two analytical techniques were used: flame atomic absorption spectroscopy (Aas) and magnetic sector mass spectrometry with inductively coupled plasma source (Icp-SFMS). In both cases, the proposed method offers a good linearity and sensitivity for each of the trace elements under study. The accuracy of the method expressed as relative standard deviation ranges from 1.4 to 2.3%. In relation to the accuracy measurement, an oil was also analyzed as a certified reference material (Conostan 500 mg/L), with the concentration of certified Mg, obtaining satisfactory results. (Author)

  10. Behaviour study of trace radioelements in the cycles of uranium conversion

    International Nuclear Information System (INIS)

    Bertaux, M.

    1998-01-01

    The aim of this work was to study the presence of ultra-trace radioelements in the cycles of uranium conversion. Radiochemical methods for determining ultra-trace amounts of various elements in uranium have been perfected. These methods are based on the chromatographic separation of anionic complexes and on the measurement of various activities by alpha spectrometry. Thus, the source of these traces has been determined and a work of tracing has been carried out in the Malvesi site (uranium purification unit). This work has revealed an accumulation of these traces in the uranium purification column, consequently to their extraction by the TBP. A decontamination process of weakly contaminated uranium batches has been proposed using the Parex computer model and tested at the industrial scale. This process is based on the U(VI) extraction by the TBP/ISOPAR mixture and on the use of oxalic acid as the complexing agent of the tetravalent actinides in aqueous phase. It has been tested with success during a purification study of a batch of about 4 tons of uranium contaminated by traces of various radioelements. The preliminary study had taken into account the influence of metallic impurities (iron, nickel, copper) on the radioelements complexation by the oxalate ions. (O.M.)

  11. Comparison of trace element contamination levels (Cu, Zn, Fe, Cd ...

    African Journals Online (AJOL)

    SERVER

    2008-03-18

    Mar 18, 2008 ... Chemical analysis of the trace elements in the soft tissues. The trace elements of interest (Cu, Zn, Fe, Pb, Cd) were then determined in the digested solutions, using Thermoelemental type. M6 brand of an atomic absorption Spectrometer equipped with a flame operated atomisation system and a deuterium ...

  12. Evaluation of the impact of general phosphate fertilizers factories company on the surrounding environment by determining natural radionuclides and some trace elements in air particulates

    International Nuclear Information System (INIS)

    Al-Masri, M. S.; Al-Kharfan, K.; Al-Hamwi, A.; Al-Shamali, K.

    2004-01-01

    Natural radionuclides and some trace element levels in air particulates of the areas surrounding the phosphate fertilizers factory in Homs have been determined Mean total air particulates concentration ranged from 31 μg/m3 in Kerba Al-Teen in Autumn period. While trace element concentrations in air particulates were relatively high in air particulates collected from AECS center and other sites situated north east of the factory; about 1.7 ng/m3 in AECS site and 1.7 ng/m3 in Abel for uranium and cadmium, respectively. In addition, radioactivity analysis of air particulates has shown low levels of polonium 210 and lead 210; a value of 2 mBq/m3 in Kerba Al-Teen has not been exceeded. However, air particulate, natural radionuclides and the studied trace elements concentrations in the surrounding areas were within the natural levels. Therefore, air emissions from the factory containing radioactive materials and trace elements are relatively low. This is due to strict control procedures on transport and loading processes of phosphate in addition to the high efficiency of filters used for air emissions from the phosphate fertilizers factory during the study period (2002). (author)

  13. Evaluation of the impact of general phosphate fertilizers factories company on the surrounding environment by determining natural radionuclides and some trace elements in air particulates

    International Nuclear Information System (INIS)

    Al-Masri, M. S.; Al-Kharfan, K.; Al-Hamwi, A.; Al-Shmali, K.; Abdul Haleem, M.

    2003-12-01

    Natural radionuclides and some trace element levels in air particulates of the areas surrounding the phosphate fertilizers factory in Homs have been determined mean total air particulates concentration ranged from 31μg/m 3 in Kerba Al-Teen in autumn period. While trace element concentrations in air particulates were relatively high in air particulates collected from AECS center and other sites situated north east of the factory: about 1.7 ng/m 3 in AECS site and 1.7 ng/m 3 in Abel for uranium and cadmium, respectively. In addition, radioactivity analysis of air particulates have shown low levels of polonium 210 and lead 210, a value of 2 mBg/m 3 in Kerba Al-Teen has not been exceeded. However, air particulate, natural radionuclides and the studied trace elements concentrations in the surrounding areas were within the natural levels. Therefore, air emissions from the factory containing radioactive materials and trace elements are relatively low. This is due to strict control procedures on transport and loading processes of phosphate in addition to the high efficiency of filters used for air emissions from the phosphate fertilizers factory during the study period (2002).(author)

  14. Trace element analysis in the serum and hair of Antarctic leopard seal, Hydrurga leptonyx, and Weddell seal, Leptonychotes weddellii

    Energy Technology Data Exchange (ETDEWEB)

    Gray, Rachael [Faculty of Veterinary Science, University of Sydney, NSW 2006 Australia (Australia); Australian Marine Mammal Research Centre PO Box 20 Mosman, NSW 2088 (Australia)], E-mail: rgray@vetsci.usyd.edu.au; Canfield, Paul [Faculty of Veterinary Science, University of Sydney, NSW 2006 (Australia); Rogers, Tracey [Australian Marine Mammal Research Centre PO Box 20 Mosman, NSW 2088 (Australia); Evolution and Ecology Research Centre and School of Biological Earth and Environmental Sciences, University of New South Wales, NSW 2052 (Australia)

    2008-07-25

    Leopard seal, Hydrurga leptonyx, and Weddell seal, Leptonychotes weddellii, occupy an upper trophic level within the Antarctic ecosystem and are useful indicator species in the Southern Ocean of trace element concentrations. Reference values for the concentration of 19 trace elements were determined in the serum and hair of leopard and Weddell seals sampled in Eastern Antarctica. These reference values can be used as 'baseline' levels for monitoring trace element concentrations in these species. Greater trace element concentrations were determined in hair compared to serum, indicating different time scales of trace element accumulation in these samples. For the majority of trace elements, except for Se in the leopard seal samples and Cr in the Weddell seal samples, significant regression relationships for trace element concentrations in hair and serum were not elucidated. Significant differences were determined in the concentrations of seven out of 15 elements with hair type, moult and new, in the leopard seal; concentrations in moult hair were determined to be greater than in new hair for all elements except Zn. Hair analysis was determined to be useful for monitoring exposure to trace elements and when collected off the ice from moulting seals, hair can be employed as a non-invasive sample for trace element analysis in leopard and Weddell seals.

  15. Modification of working parameters for routine determination of trace elemental impurities in PuO2 samples by direct current arc-AES

    International Nuclear Information System (INIS)

    Pant, D.K.; Phadke, M.P.; Dapolikar, T.T.; Kapur, H.N.; Kumar, Rajendra; Dubey, K.

    2015-01-01

    In the present work we have altered the parameters of routine method to determine the trace elemental impurities in PuO 2 samples using DC arc source optically coupled with CCD based spectrometer system. The method is basically a fractional distillation technique using DC arc source, involving ignition, dilution of the sample with U 3 O 8 containing carrier mixture, arcing of the sample/standard mixture in DC arc and measurement of analyte signals by spectrometer system. In all fifteen elemental impurities including Boron and Cadmium were determined. Detection limits are comparable with ICP-AES method. (author)

  16. Uptakes of trace elements in Zn-deficient mice

    International Nuclear Information System (INIS)

    Ohyama, T.; Yanaga, M.; Yoshida, T.; Maetsu, H.; Suganuma, H.; Omori, T.

    2002-01-01

    A multitracer technique was used to obtain uptake rates of essential trace elements in various organs and tissues in Zn-deficient mice. A multitracer solution, containing more than 20 radioisotopes, was injected intraperitoneally into Zn-deficient state mice and control ones. Uptake rates of the radioisotopes were compared with concentrations of trace elements determined by instrumental neutron activation analysis (INAA) in order to study a specific metabolism of Zn and other essential trace elements, such as Mn, Co, Se, Rb, and Sr. The result suggests that Zn is supplied from bone to other organs and tissues and an increase in Co concentration in all organs and tissues depends on its chemical form, under the Z-deficient state. (author)

  17. Nutritional values of trace elements in dried desserts

    International Nuclear Information System (INIS)

    Kyritsis, A.; Kanias, G.D.; Tzia, C.

    1997-01-01

    Desserts are the most aromatic and delicious parts of meals, and also a source of nutrient trace elements for the human body. In this work, instrumental neutron activation analysis has been applied to determine the trace elements antimony, chromium, cobalt, iron, manganese, potassium, rubidium, scandium, sodium and zinc in creme caramel, ice-creams, jellies and mousse dried desserts from the Greek market. According to our results, their classification as nutrient trace element sources for the human body is: mousse>ice-cream> creme caramel> jelly. Among the different studied flavours, chocolate and its derivatives are the richest in nutrient trace elements. Moreover, the consumption of one portion of a chocolate mousse dessert can offer to the human body about 60% of the daily required chromium, 40% of the daily required iron, 10% of the daily required manganese and potassium and 4% of the daily required sodium. (author)

  18. Measuring protein isoelectric points by AFM-based force spectroscopy using trace amounts of sample

    Science.gov (United States)

    Guo, Shifeng; Zhu, Xiaoying; Jańczewski, Dominik; Lee, Serina Siew Chen; He, Tao; Teo, Serena Lay Ming; Vancso, G. Julius

    2016-09-01

    Protein charge at various pH and isoelectric point (pI) values is important in understanding protein function. However, often only trace amounts of unknown proteins are available and pI measurements cannot be obtained using conventional methods. Here, we show a method based on the atomic force microscope (AFM) to determine pI using minute quantities of proteins. The protein of interest is immobilized on AFM colloidal probes and the adhesion force of the protein is measured against a positively and a negatively charged substrate made by layer-by-layer deposition of polyelectrolytes. From the AFM force-distance curves, pI values with an estimated accuracy of ±0.25 were obtained for bovine serum albumin, myoglobin, fibrinogen and ribonuclease A over a range of 4.7-9.8. Using this method, we show that the pI of the ‘footprint’ of the temporary adhesive proteins secreted by the barnacle cyprid larvae of Amphibalanus amphitrite is in the range 9.6-9.7.

  19. Determination of trace elements in the human hair reference material, HH-I, by neutron activation analysis and atomic absorption spectrophotometry

    International Nuclear Information System (INIS)

    Coetzee, P.; Pieterse, H.

    1986-01-01

    Analytical procedures are presented and problem areas identified with regard to the determination of trace elements in IAEA powdered human hair reference material, HH-I, of limited sample size (100-200 mg), by NAA and graphite furnace AAS. Results obtained for the twelve elements As, Cd, Co, Cr, Cu, Fe, Hg, Mn, Ni, Sb, Se, and Zn studied in human hair and other biological reference material like orchard leaves, seaplant material, and copepod compare satisfactorily with the certified values

  20. Investigations on the determination of traces of some rare earths (Eu, Sm, Gd, Y) in oxides of rare earths (Y2O3, Sm2O3, Gd2O3) by emission spectrography in d.c. arc

    International Nuclear Information System (INIS)

    Dittrich, K.; Gajek, M.; Luan, P.

    1978-01-01

    The evaporation of traces and matrices of rare earth elements was investigated in different atmospheres. It was found, that low-boiling rare earths elements, because of their extended formation of carbides evaporate more slowly than high-boiling rare earths elements. The evaporation of the traces depends on the matrices. 3 cases for the determination of traces of rare earths elements in oxides of other rare earths elements are derived from the results of the evaporation: Low- to high-boiling traces of rare earths elements in low-boiling matrices of rare earths elements, low-boiling traces in medium- to high-boiling matrices, and medium- to high-boiling traces in medium- to high-boiling matrices. The results of the determination are: in Y 2 O 3 : 14 ppm Sm, 2 ppm Eu; in Gd 2 O 3 : 18 ppm Y, 3 ppm Sm, 2 ppm Eu; in Sm 2 O 3 : 70 ppm Y, 370 ppm Gd, 16 ppm Eu. (author)

  1. Application of ray-traced tropospheric slant delays to geodetic VLBI analysis

    Science.gov (United States)

    Hofmeister, Armin; Böhm, Johannes

    2017-08-01

    The correction of tropospheric influences via so-called path delays is critical for the analysis of observations from space geodetic techniques like the very long baseline interferometry (VLBI). In standard VLBI analysis, the a priori slant path delays are determined using the concept of zenith delays, mapping functions and gradients. The a priori use of ray-traced delays, i.e., tropospheric slant path delays determined with the technique of ray-tracing through the meteorological data of numerical weather models (NWM), serves as an alternative way of correcting the influences of the troposphere on the VLBI observations within the analysis. In the presented research, the application of ray-traced delays to the VLBI analysis of sessions in a time span of 16.5 years is investigated. Ray-traced delays have been determined with program RADIATE (see Hofmeister in Ph.D. thesis, Department of Geodesy and Geophysics, Faculty of Mathematics and Geoinformation, Technische Universität Wien. http://resolver.obvsg.at/urn:nbn:at:at-ubtuw:1-3444, 2016) utilizing meteorological data provided by NWM of the European Centre for Medium-Range Weather Forecasts (ECMWF). In comparison with a standard VLBI analysis, which includes the tropospheric gradient estimation, the application of the ray-traced delays to an analysis, which uses the same parameterization except for the a priori slant path delay handling and the used wet mapping factors for the zenith wet delay (ZWD) estimation, improves the baseline length repeatability (BLR) at 55.9% of the baselines at sub-mm level. If no tropospheric gradients are estimated within the compared analyses, 90.6% of all baselines benefit from the application of the ray-traced delays, which leads to an average improvement of the BLR of 1 mm. The effects of the ray-traced delays on the terrestrial reference frame are also investigated. A separate assessment of the RADIATE ray-traced delays is carried out by comparison to the ray-traced delays from the

  2. On-site Determination of Trace Arsenic by Reflection-Absorption Colorimetry of Molybdenum Blue Collected on a Membrane Filter.

    Science.gov (United States)

    Hasegawa, Yuya; Suzuki, Yasutada; Kawakubo, Susumu

    2017-01-01

    An on-site determination method for trace arsenic has been developed by collecting it as molybdenum blue (MB) in the presence of tetradecyldimethylbenzylammonium chloride on a mixed cellulose ester membrane filter and by measuring reflection absorbance (RA) of MB on the filter using a laboratory-made palm-top size reflection-absorbance colorimeter with a red light-emitting diode. The value of RA was proportional to the amount of arsenic up to 0.5 μg with a detection limit of 0.01 μg. The proposed method was successfully applied to soil extract and hot-spring water samples.

  3. Experiments made to separate the trace elements in seawater by extraction and their determination by neutron activation analysis

    International Nuclear Information System (INIS)

    Heuss, E.; Lieser, K.H.

    1979-01-01

    The problems of trace element determination in seawater by neutron activation analysis are discussed. Experiments with tri-n-octylphosphinoxide (TOPO) did not bring satisfactory results because of the strong interference of the bremsstrahlung from 32 P. Experiments with oxin at different pH showed that in each case only few elements are extracted in greater amounts. An extraction apparatus is described making possible the extraction of up to 10 l water by 50 ml of an organic solution. Extraction experiments using different complexing agents were satisfactory but the evaporation of the organic phase to dryness for irradiation was difficult. (author)

  4. Preparation of an estuarine sediment quality control material for the determination of trace metals

    Directory of Open Access Journals (Sweden)

    Hatje Vanessa

    2006-01-01

    Full Text Available Quality Control Materials (QCM have being used routinely in daily laboratory work as a tool to fill the gap between need and availability of Certified Reference Materials (CRM. The QCM are a low-cost alternative to CRMs, and they are in high demand, especially, for the implementation of quality control systems in laboratories of several areas. This paper describes the preparation of a QCM for the determination of trace metals in estuarine sediments and the results of an interlaboratory exercise. Homogeneity and stability studies were performed and analysis of variance was carried out with the results. No statistical significant differences were observed in the concentrations of Co, Cr, Cu, Mn, Pb and Zn between- or within bottle results. Neither the storage nor temperature affected the results. Therefore, the QCM produced is considered homogeneous and stable and can be used for statistical control charts, evaluation of reproducibility and interlaboratory exercises.

  5. Determination of trace impurities in high purity water by emission spectroscopy and flame photometry

    International Nuclear Information System (INIS)

    Charbel, M.Y.; Lordello, A.R.

    1985-01-01

    A spectrochemical method for the determination of trace amounts of Fe, Mg, Mn, Sn, Cr, Bi, Ni, Ca, Na, Zn, Sr, Al, Ba and Cu in high purity water is described. In addition Na, Li and K are measured by flame photometry. The standards used in the spectrochemical method are prepared by evaporation in hot plate of 50 mL standard solution in Teflon becker to dryness, the residue being dissolved with 500 μL hot HCl (1:1). Four hundred μL of this solution is evaporated under infra-red lamp on Apiezon treated flat top graphite electrodes. The residue is submitted to a direct current arc excitation. The accuracy is estimated by the spectrochemical method with a direct procedure sample preparation. The relative standard deviation varies from +- 4% to +- 27%. For the elements Na, Li and K standard solutions are concentrated fiftyfold by a simple evaporation procedure and then measured by flame photometry. The standard deviation and accuracy are given. (Author) [pt

  6. The spectrographic determination of minor and trace elements in copper, lead, and zinc concentrates

    International Nuclear Information System (INIS)

    Breckenridge, R.L.; Russell, G.M.; Watson, A.E.

    1976-01-01

    This report deals with the development of a method for the determination, by an emission-spectrographic technique, of magnesium, manganese, aluminium, silver, calcium, chromium, cobalt, titanium, antimony, cadmium, molybdenum, zirconium, nickel, boron, vanadium, arsenic, beryllium, tin, germanium, and bismuth in copper, lead, and zinc sulphide concentrates. The method involves the preparation of complex standards in which the volatile elements arsenic, antimony, cadmium, tin, and bismuth are incorporated as sulphide compounds at temperatures of 800 degrees Celsius in evacuated silica tubes together with a synthetic sulphide matrix. These standards are then mixed with the other minor and trace elements to form composite standards. The conditions for excitation with a direct-current arc, and the analytical lines for the elements and internal standards, are given. The procedure is rapid and convenient, and involves the minimum of sample preparation. The accuracy is about 10 per cent, and the method has a coefficient of variation for the various elements of between 2 and 13 per cent

  7. Trace elements in Taiwanese diet in different seasons

    International Nuclear Information System (INIS)

    Sheng-Ming Liu; Chien Chung

    1992-01-01

    The trace element contents of Taiwanese diet were determined using conventional neutron activation analysis. Sample were prepared with duplicate portion technique by collecting food items ate and drank during a 3 day period in winter. Samples were homogenized, freeze-dried, and elemental concentration of trace elements were determined by instrumental neutron activation analysis. The interference from fast neutron induced reactions were corrected. Concentrations and daily dietary intake of the elements were compared with those collected in the summer, resulting less daily intake of K, Ca, Mn, Fe and Zn among Taiwanese than the values recommended by WHO and RDA. Alarming low intake of Fe for females and Zn among Taiwanese were indicated. (author) 6 refs.; 2 figs.; 5 tabs

  8. Trace element content of human hair determined using neutron activation analysis as monitor of exposure effects to environmental metals

    International Nuclear Information System (INIS)

    Dutkiewicz, T.; Paprotny, W.; Sokolowska, D.; Kulka, E.; Woyciechowska, E.; Dybczynski, R.; Sterlinski, S.

    1978-01-01

    Determination of 17 trace elements, mainly metals, in small hair samples by neutron activation analysis was elaborated. The number of elements determined in one sample made it possible to assess quickly the exposure of human population in a given region. The hair samples after careful washing according to procedure elaborated previously were irradiated in high reactor neutron flux (approximately 10 14 n.cm -2 .s -1 ). The activities of samples were measured three times (for different decay times) by means of Ge(Li) gamma-ray spectrometer. A new version of the comparator technique, called a triple-single comparator method, was applied for quantitative analysis. The statistical methods used for planning of sampling and preliminary results on evaluation of analytical data are also described. (author)

  9. Determination of trace elements in acid rain by reversed phase extraction chromatography and neutron activation

    International Nuclear Information System (INIS)

    Rao, R.R.; Goski, D.G.; Chatt, A.

    1991-01-01

    A preconcentration neutron activation analysis (PNAA) method has been developed for the simultaneous determination of selected trace elements in acid rain and other water samples. The method consists of preconcentration of the elements by reversed phase extraction chromatography using oxine-loaded Amberlite XAD-2 resin. Nearly 100% recoveries were obtained for Co, Cu, Hg, V and Zn at pH 6.0 and for Cd at pH 7.0. Manganese gave incomplete recoveries at the pH range of 4.0-8.0 studies. Various factors that can influence preconcentration of the elements have been investigated in detail. The precision and accuracy of measurements have been evaluated by analyzing certified reference materials. The detection limits have been found to be of the order of ppb. The PNAA method has been applied to a number of acid rain and other water samples

  10. Trace metal assay of uranium silicide fuel

    International Nuclear Information System (INIS)

    Kulkarni, M.J.; Argekar, A.A.; Thulasidas, S.K.; Dhawale, B.A.; Rajeswari, B.; Adya, V.C.; Purohit, P.J.; Neelam, G.; Bangia, T.R.; Page, A.G.; Sastry, M.D.; Iyer, R.H.

    1994-01-01

    A comprehensive trace metal assay of uranium silicide, a fuel for nuclear research reactors that employs low-enrichment uranium, is carried out by atomic spectrometry. Of the list of specification elements, 21 metallic elements are determined by a direct current (dc) arc carrier distillation technique; the rare earths yttrium and zirconium are chemically separated from the major matrix followed by a dc arc/inductively coupled argon plasma (ICP) excitation technique in atomic emission spectrometry (AES); silver is determined by electrothermal atomization-atomic absorption spectrometry (ETA-AAS) without prior chemical separation of the major matrix. Gamma radioactive tracers are used to check the recovery of rare earths during the chemical separation procedure. The detection limits for trace metallics vary in the 0.1- to 40-ppm range. The precision of the determinations as evaluated from the analysis of the synthetic sample with intermediate range analyte concentration is better than 25% relative standard deviation (RSD) for most of the elements employing dc arc-AES, while that for silver determination by ETS-AAS is 10% RSD. The precision of the determinations for four crucially important rare earths by ICP-AES is better than 3% RSD

  11. Determination of trace levels of nickel and manganese in soil, vegetable, and water

    Energy Technology Data Exchange (ETDEWEB)

    Khani, Rouhollah; Shemirani, Farzaneh [School of Analytical Chemistry, University College of Science, University of Tehran, Tehran (Iran, Islamic Republic of)

    2010-12-15

    A simple and reliable method for rapid and selective extraction and determination of trace levels of Ni{sup 2+} and Mn{sup 2+} was developed by ionic liquid (IL) based dispersive liquid-liquid microextraction coupled to flame atomic absorption spectrometry (FAAS) detection. The proposed method was successfully applied to the preconcentration and determination of nickel and manganese in soil, vegetable, and water samples. After preconcentration, the settled IL-phase was dissolved in 100 {mu}L of ethanol and aspirated into the FAAS using a home-made microsample introduction system. Injection of 50 {mu}L of each analyte into an air-acetylene flame provided very sensitive spike-like and reproducible signals. Effective parameters such as pH, amount of IL, volume of the disperser solvent, concentration of the chelating agent, and effect of salt concentration were inspected by a (2{sup 5-1}) fractional factorial design to identify the most important parameters and their interactions. Under optimum conditions, preconcentration of 10 mL sample solution permitted the detection of 0.93 {mu}g L{sup -1} Ni{sup 2+} and 0.52 {mu}g L{sup -1} Mn{sup 2+} with enrichment factors 77.2 and 82.6 for Ni{sup 2+} and Mn{sup 2+}, respectively. The accuracy of the procedure was evaluated by analysis of a certified reference material (CRM TMDW-500, drinking water). (Copyright copyright 2010 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  12. Levels and occupational health risk assessment of trace metals in ...

    African Journals Online (AJOL)

    The levels of trace metals (Pb, Cu, Ni and Cd) were determined in soils from a major automobile repair workshop located in Uyo, Akwa Ibom State, Nigeria. This was carried out to evaluate the potential occupational risk to operators working in and around the site. The mean of trace metal levels were: lead (14.52 mg/kg); ...

  13. Oesophageal cancer in the Transkei. Determination of trace element concentrations in selected plant material by instrumental neutron activation analysis

    International Nuclear Information System (INIS)

    Renan, M.J.; Drennan, B.D.; Keddy, R.J.; Sellschop, J.P.F.

    1979-01-01

    The results of the analysis by instrumental neutron activation for the concentration of trace elements in plant materials from certain areas in the Transkei region of southern Africa are presented. These areas are selected for their characteristic high or low incidence of carcinoma of the oesophagus. To broaden the suite of elements for which analysed and to overcome some of the limitations of neutron activation analysis, certain other nuclear analyses and methods are suggested which, if utilized, would increase the number of elements determined, and so improve the information available. (author)

  14. Distribution of trace elements in the coastal sea sediments of Maslinica Bay, Croatia

    Science.gov (United States)

    Mikulic, Nenad; Orescanin, Visnja; Elez, Loris; Pavicic, Ljiljana; Pezelj, Durdica; Lovrencic, Ivanka; Lulic, Stipe

    2008-02-01

    Spatial distributions of trace elements in the coastal sea sediments and water of Maslinica Bay (Southern Adriatic), Croatia and possible changes in marine flora and foraminifera communities due to pollution were investigated. Macro, micro and trace elements’ distributions in five granulometric fractions were determined for each sediment sample. Bulk sediment samples were also subjected to leaching tests. Elemental concentrations in sediments, sediment extracts and seawater were measured by source excited energy dispersive X-ray fluorescence (EDXRF). Concentrations of the elements Cr, Cu, Zn, and Pb in bulk sediment samples taken in the Maslinica Bay were from 2.1 to over six times enriched when compared with the background level determined for coarse grained carbonate sediments. A low degree of trace elements leaching determined for bulk sediments pointed to strong bonding of trace elements to sediment mineral phases. The analyses of marine flora pointed to higher eutrophication, which disturbs the balance between communities and natural habitats.

  15. Adaptation of atomic spectrometric methods for the determination of trace elements in whole blood and blood fractions

    International Nuclear Information System (INIS)

    Prohaska, C.

    2002-05-01

    Analytical methods were developed and optimized for the determination of the elements Ca, Cr, Cu, Fe, Mg, Mn, Se, V and Zn in whole blood and in the blood fractions plasma, erythrocytes and lymphocytes of a group of people suffering from diabetes and of a control group of healthy individuals. Cr, Mn, Se and V were analyzed by ETAAS. Ca, Cu, Fe, Mg and Zn were analyzed by ICP-OES. The status of trace elements in lymphocytes of people suffering from diabetes is changed. Physiologically interesting correlations were observed between the clinical parameters cholesterol, HDL, LDL, blood glucose, HbA1c, age and BMI and the trace element concentrations, e.g. a correlation of blood glucose and HbA1c with selenium in whole blood. An ETAAS - method for the determination of Co and Mo was developed and optimized. The samples were digested applying a mixture of HNO3 and HF, different types of graphite furnaces were tested and a multiple injection technique was applied, thereby enabling a contribution to the normal values of these elements in human whole blood. An on-line coupling of a LC, controlled by FIA, with an ICP-OES was developed to investigate the concentrations of the iron species Fe(II) and Fe(III) and the copper species Cu(I) and Cu(II) in human blood plasma. The ICP-OES instrument was adapted, batch experiments were carried out, oxidizing and reducing agents were added and the acidity of the eluens, the flow rate and the integration time were optimized. Choosing alanine for complexation of the species of interest enables their separation under physiological conditions. In the real plasma samples measured most of the copper and iron was found in their oxidized forms. (author)

  16. A survey of Trace Metals Determination in Hospital Waste Incinerator in Lucknow City, India

    Directory of Open Access Journals (Sweden)

    Ranjan Kumar

    2004-08-01

    Full Text Available Information on the elemental content of incinerator burning of human organ, animal and medical waste is scanty in India Nineteen trace elements were analyzed in the incinerator ash from four major hospitals, one municipal waste incinerator and two R & D laboratories engaged in animal experiment in Lucknow city. Concentrations of Zinc and Lead were found to be very high in comparison to other metals due to burning of plastic products. The source of Ca, P and K are mainly bone, teeth and other animal organs. A wide variation in trace concentration of several toxic elements have been seen due to variation in initial waste composition, design of the incinerator and operating conditions.

  17. High precision ray tracing in cylindrically symmetric electrostatics

    Energy Technology Data Exchange (ETDEWEB)

    Edwards Jr, David, E-mail: dej122842@gmail.com

    2015-11-15

    Highlights: • High precision ray tracing is formulated using power series techniques. • Ray tracing is possible for fields generated by solution to laplace's equation. • Spatial and temporal orders of 4–10 are included. • Precisions in test geometries of hemispherical deflector analyzer of ∼10{sup −20} have been obtained. • This solution offers a considerable extension to the ray tracing accuracy over the current state of art. - Abstract: With the recent availability of a high order FDM solution to the curved boundary value problem, it is now possible to determine potentials in such geometries with considerably greater accuracy than had been available with the FDM method. In order for the algorithms used in the accurate potential calculations to be useful in ray tracing, an integration of those algorithms needs to be placed into the ray trace process itself. The object of this paper is to incorporate these algorithms into a solution of the equations of motion of the ray and, having done this, to demonstrate its efficacy. The algorithm incorporation has been accomplished by using power series techniques and the solution constructed has been tested by tracing the medial ray through concentric sphere geometries. The testing has indicated that precisions of ray calculations of 10{sup −20} are now possible. This solution offers a considerable extension to the ray tracing accuracy over the current state of art.

  18. Known knowns, known unknowns and unknown unknowns in prokaryotic transposition.

    Science.gov (United States)

    Siguier, Patricia; Gourbeyre, Edith; Chandler, Michael

    2017-08-01

    Although the phenomenon of transposition has been known for over 60 years, its overarching importance in modifying and streamlining genomes took some time to recognize. In spite of a robust understanding of transposition of some TE, there remain a number of important TE groups with potential high genome impact and unknown transposition mechanisms and yet others, only recently identified by bioinformatics, yet to be formally confirmed as mobile. Here, we point to some areas of limited understanding concerning well established important TE groups with DDE Tpases, to address central gaps in our knowledge of characterised Tn with other types of Tpases and finally, to highlight new potentially mobile DNA species. It is not exhaustive. Examples have been chosen to provide encouragement in the continued exploration of the considerable prokaryotic mobilome especially in light of the current threat to public health posed by the spread of multiple Ab R . Copyright © 2017 Elsevier Ltd. All rights reserved.

  19. Quantum circuits cannot control unknown operations

    International Nuclear Information System (INIS)

    Araújo, Mateus; Feix, Adrien; Costa, Fabio; Brukner, Časlav

    2014-01-01

    One of the essential building blocks of classical computer programs is the ‘if’ clause, which executes a subroutine depending on the value of a control variable. Similarly, several quantum algorithms rely on applying a unitary operation conditioned on the state of a control system. Here we show that this control cannot be performed by a quantum circuit if the unitary is completely unknown. The task remains impossible even if we allow the control to be done modulo a global phase. However, this no-go theorem does not prevent implementing quantum control of unknown unitaries in practice, as any physical implementation of an unknown unitary provides additional information that makes the control possible. We then argue that one should extend the quantum circuit formalism to capture this possibility in a straightforward way. This is done by allowing unknown unitaries to be applied to subspaces and not only to subsystems. (paper)

  20. Zinc and palladium traces separation from uranium by tri-n-octylamine extraction. Direct determination in organic phase by atomic absorption

    Energy Technology Data Exchange (ETDEWEB)

    de Moraes, S; Cipriani, M; Abrao, A

    1974-12-01

    A procedure for the extraction and determination of Zn and Pd as traces from nuclear grade uranium ADU, UO/sub 2/, UO/sub 3/, U/sub 3/O/sub 8/ is introduced. The elements are extracted from UO/sub 2/Cl/sub 2/-HCl-KI solution with tri-n-octylamine in benzene and determined by atomic absorption spectrophotometry. The adition of potassium iodide to the UO/sub 2/Cl/sub 2/-HCl solutions improved the extraction of both elements. Direct burn of the organic phase in the atomic absorption spectrophotometer using hydrogen-air flame provided enhancement of the absorbance for both elements. The relative standard deviations were Zn, 3% and Pd, 2.9%.

  1. Characterisation of airborne particles in the assessment of air quality: a case study for trace metal determination

    International Nuclear Information System (INIS)

    Norhayati Mohd Tahir; Poh Seng Chee; Suhaimi Suratman; Noor Azhar Mohamed Shazili; Suhaimi Hamzah; Abd Khalik Wood; Syamsiah Abd Rahman; Mhd Radzi Abas

    2005-01-01

    A study to determine the concentration of total suspended particulate (TSP) and trace metals concentration in the atmospheric particulate was done in Kuala Terengganu town. TSP was collected using high volume sampler. The sampled filter paper were subjected to microwave assisted acid digestion and the metals were determined using inductive couple plasma with optical emission spectrophotometer (ICP-OES). Results indicated a significant spatial variation but generally the TSP concentrations recorded in this study are still below the recommended Malaysia guideline for TSP. Some of the elemental composition of particulate aerosol is clearly correlation and enrichment analyses, the elements could be grouped into two; Pb, Cd and Zn group could be related to the vehicular emission sources whist the Al, Fe, Mn and Cr group appears to be crustal origin. It can also be concluded that the levels of Pb, Cd and Zn in the study area are generally lower than other cities in Malaysia. (Author)

  2. The determination of low level trace elements in coals by laser ablation-inductively coupled plasma-mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Booth, C.A.; Spears, D.A.; Krause, P.; Cox, A.G. [University of Sheffield, Sheffield (United Kingdom). Dept. of Earth Sciences

    1999-11-01

    The rapid determination of elements present in low level concentrations in bituminous coals is possible using laser abalation-inductively coupled plasma-mass spectrometry (l.a.-i.c.p.-m.s.). A wide range of trace elements can routinely be determined using this technique but it is for environmentally sensitive elements, such as As, Cd, Mo, Sb, Se and Hg, that it is of most use due to the low levels of detection. Calibration of the i.c.p.-m.s. was achieved using a series of uncertified coals and the method evaluated using the South African certified coals, Sarm 18, 19 and 20. A critical evaluation of the data obtained shows that for many of the elements studied the results obtained are both accurate and precise, even at very low concentrations, with the limits of detection for all of the elements being in the {mu}g/kg (parts per billion) range. 6 refs., 3 figs., 9 tabs.

  3. Identifying sources of groundwater pollution using trace element signatures

    International Nuclear Information System (INIS)

    Olmez, I.; Hayes, M.J.

    1990-01-01

    A simple receptor modeling approach has been applied to groundwater pollution studies and has shown that marker trace elements can be used effectively in source identification and apportionment. Groundwater and source materials from one coal-fired and five oil-fired power plants, and one coal-tar deposit site have been analyzed by instrumental neutron activation analysis for more than 20 minor and trace elements. In one of the oil-fired power plants, trace element patterns indicated a leak from the hazardous waste surface impoundments owing to the failure of a hypolon liner. Also, the extent and spatial distribution of groundwater contamination have been determined in a coal-tar deposit site

  4. Determination of trace thorium in water samples by flow injection fluorescence spectrophotometry with microcolumn on-line preconcentration

    International Nuclear Information System (INIS)

    Shen Zhuqin; Zhang Yanan; Guo Dongfa; Huang Yun

    1991-01-01

    An on-line preconcentration time resolved fluorimetric method was developed for the determination of trace thorium in water, based on luminescence of complex Th-morin-TOPO (or TRPO)-sodium lauryl sulfate in sulfuric acid medium. Interferences from companied cations, such as Al 3+ and Zr 4+ , which emit fluorescence with much slower rising rate at the same condition were effectively eliminated through optimization of the manifold parameters and precisely controlling of the elution flow rate. Effects of nearly 40 ions were also investigated. The detection limit, the liner range and relative standard deviation for 50 ng Th are 2.5 ng/L, 0∼80 ng and 3.6%, respectively. Sampling rate is 30 per hour

  5. PIXE analysis of trace elements in cetacean teeth

    International Nuclear Information System (INIS)

    Mitani, Yoko; Arai, Nobuaki; Sakamoto, Wataru; Yoshida, Koji

    1997-01-01

    PIXE was adopted for analysis of trace elements in teeth of two species of cetaceans, sperm whale (Physeter microcephalus) and pantropical spotted dolphin (Stenella attenuata). The analyses were performed along with the growth layer of the teeth, which is formed annually, suitable for age determination. Mn, Fe, Cu, Zu and Sr were detected in the teeth of sperm whale and pantropical spotted dolphin. Among these trace elements, gradual increase was observed for Zn/Ca ratio in the sperm whale's teeth. (author)

  6. Report on the intercomparison of determination of selected radionuclides and trace elements in water (W-1, W-2 and W-3, 1975-76)

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1976-12-01

    Water is one of the most common materials which are analyzed for the purpose of monitoring of environmental pollution. While being an apparently 'easy' matrix it can in fact pose serious problems even for an experienced analyst. Trace elements and radionuclides may 'disappear' from aqueous solutions due to adsorption on container walls and some of them due to volatilization, bacterial action, etc. Preconcentration techniques such as evaporation and freeze-drying may also lead to considerable losses of some elements. On the other hand, when the vessels employed for storing the water samples have not been adequately cleaned, some trace elements may be 'added' to the solution. The above mentioned difficulties can probably, at least in part, account for the fact that only a small part of the participating laboratories sent in their results before the original deadline. Even after setting the new deadline (30 January 1976) the results were flowing in very sluggishly over a period of a few months what obviously delayed the preparation of this report. Altogether 46 laboratories participated in the W-1 and W-2 runs and 35 in the W-3 run but only a few determined all or most of radionuclides or trace elements, respectively. The present intercomparisons were intended to provide the opportunity of checking up the analytical performance for the laboratories dealing with low level activity measurements in water as well as for those engaged in trace multielement analysis.

  7. Multi-actinide analysis with AMS for ultra-trace determination and small sample sizes: advantages and drawbacks

    Energy Technology Data Exchange (ETDEWEB)

    Quinto, Francesca; Lagos, Markus; Plaschke, Markus; Schaefer, Thorsten; Geckeis, Horst [Institute for Nuclear Waste Disposal, Karlsruhe Institute of Technology (Germany); Steier, Peter; Golser, Robin [VERA Laboratory, Faculty of Physics, University of Vienna (Austria)

    2016-07-01

    With the abundance sensitivities of AMS for U-236, Np-237 and Pu-239 relative to U-238 at levels lower than 1E-15, a simultaneous determination of several actinides without previous chemical separation from each other is possible. The actinides are extracted from the matrix elements via an iron hydroxide co-precipitation and the nuclides sequentially measured from the same sputter target. This simplified method allows for the use of non-isotopic tracers and consequently the determination of Np-237 and Am-243 for which isotopic tracers with the degree of purity required by ultra-trace mass-spectrometric analysis are not available. With detection limits of circa 1E+4 atoms in a sample, 1E+8 atoms are determined with circa 1 % relative uncertainty due to counting statistics. This allows for an unprecedented reduction of the sample size down to 100 ml of natural water. However, the use of non-isotopic tracers introduces a dominating uncertainty of up to 30 % related to the reproducibility of the results. The advantages and drawbacks of the novel method will be presented with the aid of recent results from the CFM Project at the Grimsel Test Site and from the investigation of global fallout in environmental samples.

  8. Clinic Network Collaboration and Patient Tracing to Maximize Retention in HIV Care.

    Directory of Open Access Journals (Sweden)

    James H McMahon

    Full Text Available Understanding retention and loss to follow up in HIV care, in particular the number of people with unknown outcomes, is critical to maximise the benefits of antiretroviral therapy. Individual-level data are not available for these outcomes in Australia, which has an HIV epidemic predominantly focused amongst men who have sex with men.A network of the 6 main HIV clinical care sites was established in the state of Victoria, Australia. Individuals who had accessed care at these sites between February 2011 and June 2013 as assessed by HIV viral load testing but not accessed care between June 2013 and February 2014 were considered individuals with potentially unknown outcomes. For this group an intervention combining cross-referencing of clinical data between sites and phone tracing individuals with unknown outcomes was performed. 4966 people were in care in the network and before the intervention estimates of retention ranged from 85.9%-95.8% and the proportion with unknown outcomes ranged from 1.3-5.5%. After the intervention retention increased to 91.4-98.8% and unknown outcomes decreased to 0.1-2.4% (p<.01 for all sites for both outcomes. Most common reasons for disengagement from care were being too busy to attend or feeling well. For those with unknown outcomes prior to the intervention documented active psychiatric illness at last visit was associated with not re-entering care (p = 0.04.The network demonstrated low numbers of people with unknown outcomes and high levels of retention in care. Increased levels of retention in care and reductions in unknown outcomes identified after the intervention largely reflected confirmation of clinic transfers while a smaller number were successfully re-engaged in care. Factors associated with disengagement from care were identified. Systems to monitor patient retention, care transfer and minimize disengagement will maximise individual and population-level outcomes for populations with HIV.

  9. Cloud point extraction and spectrophotometric determination of mercury species at trace levels in environmental samples.

    Science.gov (United States)

    Ulusoy, Halil İbrahim; Gürkan, Ramazan; Ulusoy, Songül

    2012-01-15

    A new micelle-mediated separation and preconcentration method was developed for ultra-trace quantities of mercury ions prior to spectrophotometric determination. The method is based on cloud point extraction (CPE) of Hg(II) ions with polyethylene glycol tert-octylphenyl ether (Triton X-114) in the presence of chelating agents such as 1-(2-pyridylazo)-2-naphthol (PAN) and 4-(2-thiazolylazo) resorcinol (TAR). Hg(II) ions react with both PAN and TAR in a surfactant solution yielding a hydrophobic complex at pH 9.0 and 8.0, respectively. The phase separation was accomplished by centrifugation for 5 min at 3500 rpm. The calibration graphs obtained from Hg(II)-PAN and Hg(II)-TAR complexes were linear in the concentration ranges of 10-1000 μg L(-1) and 50-2500 μg L(-1) with detection limits of 1.65 and 14.5 μg L(-1), respectively. The relative standard deviations (RSDs) were 1.85% and 2.35% in determinations of 25 and 250 μg L(-1) Hg(II), respectively. The interference effect of several ions were studied and seen commonly present ions in water samples had no significantly effect on determination of Hg(II). The developed methods were successfully applied to determine mercury concentrations in environmental water samples. The accuracy and validity of the proposed methods were tested by means of five replicate analyses of the certified standard materials such as QC Metal LL3 (VWR, drinking water) and IAEA W-4 (NIST, simulated fresh water). Copyright © 2011 Elsevier B.V. All rights reserved.

  10. Determination of trace elements in a cigarette paper by neutron activation analysis

    International Nuclear Information System (INIS)

    Abedinzadeh, Z.; Khalkhali, Zh.; Razeghi, M.; Parsa, B.

    The concentration of 19 trace elements in a cigarette paper (Zig-Zag Paper Company, France) which is used in making different brands of Iranian cigarettes, has been measured by neutron activation analysis, employing a high-resolution Ge(Li) detector. They include Na, K, Ca, Sc, Cr, Mn, Fe, Co, Zn, Br, Sr, Sb, Ba, Ce, Eu, Gd, Au, Hg, and Th. (author)

  11. Neurological autoantibodies in drug-resistant epilepsy of unknown cause.

    Science.gov (United States)

    Tecellioglu, Mehmet; Kamisli, Ozden; Kamisli, Suat; Yucel, Fatma Ebru; Ozcan, Cemal

    2018-03-09

    Autoimmune epilepsy is a rarely diagnosed condition. Recognition of the underlying autoimmune condition is important, as these patients can be resistant to antiepileptic drugs. To determine the autoimmune and oncological antibodies in adult drug-resistant epilepsy of unknown cause and identify the clinical, radiological, and EEG findings associated with these antibodies according to data in the literature. Eighty-two patients with drug-resistant epilepsy of unknown cause were prospectively identified. Clinical features were recorded. The levels of anti-voltage-gated potassium channel complex (anti-VGKCc), anti-thyroid peroxidase (anti-TPO), anti-nuclear antibody (ANA), anti-glutamic acid decarboxylase (anti-GAD), anti-phospholipid IgG and IgM, anti-cardiolipin IgG and IgM, and onconeural antibodies were determined. Serum antibody positivity suggesting the potential role of autoimmunity in the aetiology was present in 17 patients with resistant epilepsy (22.0%). Multiple antibodies were found in two patients (2.6%). One of these patients (1.3%) had anti-VGKCc and ANA, whereas another (1.3%) had anti-VGKCc and anti-TPO. A single antibody was present in 15 patients (19.5%). Of the 77 patients finally included in the study, 4 had anti-TPO (5.2%), 1 had anti-GAD (1.3%), 4 had anti-VGKCc (5.2%) 8 had ANA (10.3%), and 2 had onconeural antibodies (2.6%) (1 patient had anti-Yo and 1 had anti-MA2/TA). The other antibodies investigated were not detected. EEG abnormality (focal), focal seizure incidence, and frequent seizures were more common in antibody-positive patients. Autoimmune factors may be aetiologically relevant in patients with drug-resistant epilepsy of unknown cause, especially if focal seizures are present together with focal EEG abnormality and frequent seizures.

  12. Traces on sky. Unexpected results of regular observations

    Science.gov (United States)

    Churyumov, K. I.; Steklov, A. F.; Vidmachenko, A. P.; Dashkiev, N. G.; Steklov, E. A.

    2016-08-01

    If the fireball's track has noticeable angular size, it can be seen even in the daytime. After the flight, bolide remains a noticeable trace of a dust, dark against the light sky. If such a dust trail illuminated by the rays of the Sun, which had just hid behind the horizon (or even in the moonlight), it is visible as bright lanes in the night sky or in twilight. That's why we call it the twilight bolides. Usually, astronomical observations using of meteor patrols, carried out at night after the evening astronomical twilight. But from March 2013 to October 2015, the authors have obtained several thousands of different tracks in the sky over Kiev. Therefore, we have identified a special class of twilight observations of fireballs. We register the traces of invading to atmosphere of meteoroids of natural and artificial origin. At the same time, observe the traces of fireballs at the day-time are also possible. But they are less effective than in the twilight. Night observations of bright meteoric tracks can usually observe some seconds. While traces of the twilight bolides we observed from some minutes up to two hours, before they be scattered by atmospheric currents. It opens the great prospects for low-cost direct experiments probing of these tracks by using, for example, the astronomical aviation. We propose the twilight tracks are classified into the following types: AMT - aero-meteorological tracks, AST - aero-space, ATT - aero-technical, and NST - not yet classified tracks of unknown nature. During the short period of our observations (from March 2013 to 2016), was fixed falling at least a dozen fragments of cometary nuclei, at least five of sufficiently large and dozens of smaller fragments of meteoroids. The results of our observations also showed that during the morning and evening twilight over Kiev clearly visible the plume of aerosols of technical nature from the plants, factories and other production facilities.

  13. Guidelines for the determination of selected trace metals in aerosols and in wet precipitation

    International Nuclear Information System (INIS)

    1988-01-01

    This publication describes sampling and analytical procedures suitable for the collection and analysis of representative samples of atmospheric aerosols and wet precipitation for selected trace metals. 11 refs, 2 tabs

  14. Determination of trace and toxic elements in Koran rice CRM by INAA, ICP and AAS

    International Nuclear Information System (INIS)

    Yong Sam Chung; Young Ju Chung; Kyung Haeng Cho; Joung Hae Lee

    1997-01-01

    Trace and toxic elements in Certified Reference Material (CRM) made of Korean rice at the Korea Research Institute of Standards and Science have been analyzed by Instrumental Neutron Activation Analysis (INAA). Data intercomparison from the measurement with those of Atomic Absorption Spectrometry (AAS) and Induced Coupled Plasma Spectrometry (ICPS) has been studied. The powdered samples were sterilized at 1.5 x 10 6 rad in the bottles using a 60 Co source after sieving and spiking to specific elements such as As, Cd, Cr, Cu and Hg and then the homogeneity of samples was assessed. Rice flour (SRM 1568a) and standard solutions made by the National Institute of Standards Technology (NIST) were used to construct the calibration curves for the INAA and the chemical methods, respectively. The uncertainties and concentration of constituent elements were determined and the possibility of their use for analytical quality control was considered. (author)

  15. Towards the interaction between calcium carbide and water during gas-chromatographic determination of trace moisture in ultra-high purity ammonia.

    Science.gov (United States)

    Trubyanov, Maxim M; Mochalov, Georgy M; Suvorov, Sergey S; Puzanov, Egor S; Petukhov, Anton N; Vorotyntsev, Ilya V; Vorotyntsev, Vladimir M

    2018-05-16

    The current study focuses on the processes involved during the flow conversion of water into acetylene in a calcium carbide reaction cell for the trace moisture analysis of ammonia by reaction gas chromatography. The factors negatively affecting the reproducibility and the accuracy of the measurements are suggested and discussed. The intramolecular reaction of the HOCaCCH intermediate was found to be a side reaction producing background acetylene during the contact of wet ammonia gas with calcium carbide. The presence of the HOCaCCH intermediate among the reaction products is confirmed by an FTIR spectral study of calcium carbide powder exposed to wet gas. The side reaction kinetics is evaluated experimentally and its influence on the results of the gas chromatographic measurements is discussed in relation to the determination of the optimal operating parameters for ammonia analysis. The reaction gas chromatography method for the trace moisture measurements in an ammonia matrix was experimentally compared to an FTIR long-path length gas cell technique to evaluate the accuracy limitations and the resource intensity. Copyright © 2018 Elsevier B.V. All rights reserved.

  16. Comparative evaluation of trace elements in blood

    International Nuclear Information System (INIS)

    Goeij, J.J.M. de; Tjioe, P.S.; Pries, C.; Zwiers, J.H.L.

    1976-01-01

    The Interuniversitair Reactor Instituut and the Centraal Laboratorium TNO have carried out a common investigation on neutron-activation-analytical procedures for the determination of trace elements in blood. A comparative evaluation of five methods, destructive as well as non-destructive, is given. The sensitivity and reproducibility of the procedures are discussed. By combining some of the methods it is possible, starting with 1 ml blood, to give quantitative information on 14 important trace elements: antimony, arsenic, bromine, cadmium, cobalt, gold, copper, mercury, molybdenum, nickel, rubidium, selenium, iron and zinc. The methods have also been applied to sodium, chromium and potassium

  17. Vertical distribution of particulate trace elements in a street canyon determined by PIXE analysis

    International Nuclear Information System (INIS)

    Raunemaa, T.; Hautojaervi, A.; Kaisla, K.; Gerlander, M.

    1981-01-01

    Suspended particles in a street canyon were investigated by collecting air particulate matter on thin filters at heigths 2.3 to 20.5 m. The weather parameters and traffic characteristics were registered during the collection. Quantitative analysis of 15 trace elements from AI to Pb was carried out by the PIXE method using 1.8-2.0 MeV protons. The concentration of lead was found to decrease exponentially when going from street level to roof level. Almost all the trace elements analyzed were found to fall into two groups with different vertical distributions. The collected matter above 10 m height was found to be due mainly to combustion originated motor vehicle exhaust, the matter below 10 m to soil originated dust. (orig.)

  18. Medical and health-related trace element analysis by TXRF

    International Nuclear Information System (INIS)

    Greaves, E.D.

    2000-01-01

    The advantages offered with TXRF analysis by direct irradiation with monochromatic X-rays of tissue homogenates and body fluids make the technique appropriate for a number of medical and health related applications. The ability to detect low levels of toxic heavy elements is being used as an aid in accidental poisoning diagnosis and treatment, in treatment-induced toxicity control and as an accessory in medical and health research. Thus lead-in-whole-blood analysis is used in confirmation of diagnosis of victims of poisoning, or monitoring the evolution and efficiency of the clinical treatment. Measurement and control of plasma platinum levels of cancer patients undergoing chemotherapy with Pt-containing drugs includes: establishment of the drug level-tumor remission response, measurement of Pt plasma level curves and establishment of optimum dosage to minimize the nephrotoxicity of platinum, and bioequivalence comparisons of different commercially available platinum containing anticancer drugs. Analysis as an aid in clinical research applications includes: trace element determination of amniotic fluid in fetus malformation studies; analysis of brain specimens and cerebrospinal fluid in diagnosis of central nervous system disorders; the influence of trace elements in cataract genesis and the influence of heavy elements in semen quality in human reproduction studies. Human body samples require the use of monochromatized beams of x-rays in order to derive the special advantage of its use: i) The reduction in the spectrum background allowing direct irradiation of organic matter specimens. Hence human tissue and body fluids are prepared by simple procedures involving dilution, homogenization and standard addition avoiding the need for specimen digestion. This results in faster, cheaper methods that decrease sample contamination problems. ii) The presence of a large Compton scattered signal in the spectrum and its use as an internal standard reference allows further

  19. Determination of trace impurities in materials

    International Nuclear Information System (INIS)

    Parashar, D.C.

    1991-01-01

    Research work done at the National Physical Laboratory to develop new methods which are more specific and/or more sensitive has been reviewed. These methods are based on the use of existing facilities viz. atomic absorption spectrophotometry, uv-visible spectrophotometry, gas chromatography and conventional chemical methods. It is possible to determine impurities like boron at 5ppb level, phosphorus at 100 ppb and oxygen non-stoichiometry in 1:2:3 compounds with higher accuracy. Boron is determined spectrophotometrically by forming a complex with curcumin and phosphorus is determined indirectly by atomic absorption spectrophotometry by forming phosphomolybdate complex with antimony or bismuth which have 1:1 ratio with phosphorus in the complex. Gas chromatographic technique has been used to evaluate the oxygen non-stoichiometry in high temperature superconductors (1:2:3 compound) where the HTc sample is dissolved in dilute nitric acid in helium environment and the oxygen released is determined using thermal conductivity detector. (author). 19 refs., 3 figs., 4 tabs

  20. Spectrophotometric determination of trace carbaryl in water and grain samples by inhibition of the rhodamine-B oxidation.

    Science.gov (United States)

    Gupta, Nirja; Pillai, Ajai Kumar; Parmar, Prachi

    2015-03-15

    A novel, sensitive, selective and simple kinetic spectrophotometric method has been developed for determination of trace levels of carbaryl based on its inhibitory effect on the oxidation of rhodamine-B by chlorine and bromine released from reaction of potassium bromate with hydrochloric acid in micellar medium. A linear relationship was observed between the inhibitory effect and the concentration of the compound. The absorbance was monitored at the maximum wavelength of 555 nm. The effect of different parameters such as pH, temperature and concentration of rhodamine-B, potassium bromate and surfactant on the reaction were investigated and optimum conditions were established. Under the selected experimental conditions, carbaryl was determined in the range of 0.04-0.4 μg mL(-1). Sandell's sensitivity and molar absorptivity were found to be 0.00055 μg cm(-2) and 3.658×10(5) L mol(-1) cm(-1) respectively. The proposed method was applied satisfactorily for the determination of carbaryl in water and different grain samples. The results were compared with those obtained by reference method and were found to be in agreement. Copyright © 2014 Elsevier B.V. All rights reserved.

  1. Preconcentration of trace elements

    International Nuclear Information System (INIS)

    Zolotov, Yu. A.; Kuz'min, N.M.

    1990-01-01

    This monograph deals with the theory and practical applications of trace metals preconcentration. It gives general characteristics of the process and describes in detail the methods of preconcentration: solvent extraction, sorption, co-precipitation, volatilization, and others. Special attention is given to preconcentration in combination with subsequent determination methods. The use of preconcentration in analysis of environmental and biological samples, mineral raw materials, high purity substances, and various industrial materials is also considered

  2. Prevalence and Impact of Unknown Diabetes in the ICU.

    Science.gov (United States)

    Carpenter, David L; Gregg, Sara R; Xu, Kejun; Buchman, Timothy G; Coopersmith, Craig M

    2015-12-01

    Many patients with diabetes and their care providers are unaware of the presence of the disease. Dysglycemia encompassing hyperglycemia, hypoglycemia, and glucose variability is common in the ICU in patients with and without diabetes. The purpose of this study was to determine the impact of unknown diabetes on glycemic control in the ICU. Prospective observational study. Nine ICUs in an academic, tertiary hospital and a hybrid academic/community hospital. Hemoglobin A1c levels were ordered at all ICU admissions from March 1, 2011 to September 30, 2013. Electronic medical records were examined for a history of antihyperglycemic medications or International Classification of Diseases, 9th Edition diagnosis of diabetes. Patients were categorized as having unknown diabetes (hemoglobin A1c > 6.5%, without history of diabetes), no diabetes (hemoglobin A1c 6.5%, with documented history of diabetes). None. A total of 15,737 patients had an hemoglobin A1c and medical record evaluable for the history of diabetes, and 5,635 patients had diabetes diagnosed by either medical history or an elevated hemoglobin A1c in the ICU. Of these, 1,460 patients had unknown diabetes, accounting for 26.0% of all patients with diabetes. This represented 41.0% of patients with an hemoglobin A1c > 6.5% and 9.3% of all ICU patients. Compared with patients without diabetes, patients with unknown diabetes had a higher likelihood of requiring an insulin infusion (44.3% vs 29.3%; p 180 mg/dL; p < 0.0001) and hypoglycemia (8.9% vs 2.5%; blood glucose < 70 mg/dL; p < 0.0001), higher glycemic variability (55.6 vs 28.8, average of patient SD of glucose; p < 0.0001), and increased mortality (13.8% vs 11.4%; p = 0.01). Patients with unknown diabetes represent a significant percentage of ICU admissions. Measurement of hemoglobin A1c at admission can prospectively identify a population that are not known to have diabetes but have significant challenges in glycemic control in the ICU.

  3. The importance of radiochemistry and indicator methods for the chemistry of traces

    International Nuclear Information System (INIS)

    Benes, P.; Majer, V.

    1980-01-01

    Sensitivity is compared for common chemical methods with respect to nonradioactive materials and methods for determining trace amounts of radioactive substances. The concept of trace amounts is explained and some other notions and terms are discussed from the point of view of chemistry and radiochemistry. The problem of radiation effect is briefly assessed on a sample of material containing trace amounts of a radionuclide and the isotopic effect problem in hydrogen is treated. (M.S.)

  4. Determination of trace platinum by supramolecular catalytic kinetic spectrofluorimetry of {beta}-cyclodextrin-platinum-KBrO{sub 3}-salicylaldehyde furfuralhydrazone

    Energy Technology Data Exchange (ETDEWEB)

    Tang, Bo; Zhang, Ning; Chen, Zhen-Zhen; Kong, Qing-Cheng [Shandong Normal University, College of Chemistry, Chemical Engineering and Materials Science, Jinan (China)

    2006-02-01

    A supramolecular catalytic kinetic spectrofluorimetric method was developed for the determination of platinum(IV) and the possible mechanism of catalytic reaction was discussed. The method was based on the fluorescence-enhancing reaction of salicylaldehyde furfuralhydrazone (SAFH) with potassium bromate, which was catalysed by platinum(IV) in a water-ethanol medium. {beta}-Cyclodextrin ({beta}-CD) obviously sensitized the determination at pH 5.20 and 25 C. Under optimum conditions, the {beta}-CD-platinum-KBrO{sub 3}-SAFH supramolecular kinetic catalytic reaction system had excitation and emission maxima at 372 and 461 nm, respectively. The linear range of this method was 0.60-180 ng ml{sup -1} with a relative standard deviation of 1.2%, and the detection limit was 0.18 ng ml{sup -1}. Investigation of the mechanism and the effects of interferences is presented. The proposed method was applied successfully to determine trace platinum(IV) in the chemotherapeutic drug cisplatin and serum from patients with satisfactory results. (orig.)

  5. Influence of S186 on trace elements in organs of dogs

    International Nuclear Information System (INIS)

    Luo Meichu; Li Landi; Chen Guibao; Zhang Meizhen

    1993-01-01

    The authors report the influence of a radiostrontium de-cooperating agents, S186 (calcium sodium N-acetylproplysmine 1, 1-diphosphonate), on trace elements in internal organs of dogs. The trace elements contents were determined with a PE-3030 atomic absorption spectrophotometer. Compared with the control group, the trace elements (Cu, Zn and Mn) contents and the Cu/Zn ratio in organs of Beagle dogs after intramuscular injection of S186 for 30 days did not change obviously except the Cu content in the liver increased

  6. Cloud point extraction-flame atomic absorption spectrometry for pre-concentration and determination of trace amounts of silver ions in water samples.

    Science.gov (United States)

    Yang, Xiupei; Jia, Zhihui; Yang, Xiaocui; Li, Gu; Liao, Xiangjun

    2017-03-01

    A cloud point extraction (CPE) method was used as a pre-concentration strategy prior to the determination of trace levels of silver in water by flame atomic absorption spectrometry (FAAS) The pre-concentration is based on the clouding phenomena of non-ionic surfactant, triton X-114, with Ag (I)/diethyldithiocarbamate (DDTC) complexes in which the latter is soluble in a micellar phase composed by the former. When the temperature increases above its cloud point, the Ag (I)/DDTC complexes are extracted into the surfactant-rich phase. The factors affecting the extraction efficiency including pH of the aqueous solution, concentration of the DDTC, amount of the surfactant, incubation temperature and time were investigated and optimized. Under the optimal experimental conditions, no interference was observed for the determination of 100 ng·mL -1 Ag + in the presence of various cations below their maximum concentrations allowed in this method, for instance, 50 μg·mL -1 for both Zn 2+ and Cu 2+ , 80 μg·mL -1 for Pb 2+ , 1000 μg·mL -1 for Mn 2+ , and 100 μg·mL -1 for both Cd 2+ and Ni 2+ . The calibration curve was linear in the range of 1-500 ng·mL -1 with a limit of detection (LOD) at 0.3 ng·mL -1 . The developed method was successfully applied for the determination of trace levels of silver in water samples such as river water and tap water.

  7. The determination of trace quantities of thorium and uranium in thick ore samples by proton-induced x-ray emission

    International Nuclear Information System (INIS)

    Cohen, D.D.; Duerden, P.; Clayton, E.

    1979-07-01

    Proton-induced X-ray emission (PIXE) techniques have been used to estimate the concentrations of trace quantities of thorium and uranium in powdered rock and ore samples. Standards of known concentrations were prepared in a carbon matrix and the yields from these used to determine simultaneously the concentrations of thorium and uranium in the ore samples. The experimental detection limit of the technique was found to be 3 to 4 μg g -1 for a 100 μC irradiation. The appropriate matrix corrections for a carbon and ore matrix have been calculated for thick targets and taken into consideration

  8. The effects of trace element content on pyrite oxidation rates

    Science.gov (United States)

    Gregory, D. D.; Lyons, T.; Cliff, J. B.; Perea, D. E.; Johnson, A.; Romaniello, S. J.; Large, R. R.

    2017-12-01

    Pyrite acts as both an important source and sink for many different metals and metalloids in the environment, including many that are toxic. Oxidation of pyrite can release these elements while at the same time producing significant amounts of sulfuric acid. Such issues are common in the vicinity of abandoned mines and smelters, but, as pyrite is a common accessory mineral in many different lithologies, significant pyrite oxidation can occur whenever pyritic rocks are exposed to oxygenated water or the atmosphere. Accelerated exposure to oxygen can occur during deforestation, fracking for petroleum, and construction projects. Geochemical models for pyrite oxidation can help us develop strategies to mitigate these deleterious effects. An important component of these models is an accurate pyrite oxidation rate; however, current pyrite oxidation rates have been determined using relatively pure pyrite. Natural pyrite is rarely pure and has a wide range of trace element concentrations that may affect the oxidation rate. Furthermore, the position of trace elements within the mineral lattice can also affect the oxidation rate. For example, elements such as Ni and Co, which substitute into the pyrite lattice, are thought to stabilize the lattice and thus prevent pyrite oxidation. Alternatively, trace elements that are held within inclusions of other minerals could form a galvanic cell with the surrounding pyrite, thus enhancing pyrite oxidation rates. In this study, we present preliminary analyses from three different pyrite oxidation experiments each using natural pyrite with different trace element compositions. These results show that the pyrite with the highest trace element concentration has approximately an order of magnitude higher oxidation rate compared to the lowest trace element sample. To further elucidate the mechanisms, we employed microanalytical techniques to investigate how the trace elements are held within the pyrite. LA-ICPMS was used to determine the

  9. Trace elements in human milk. Part of a coordinated programme on comparative methods for the study of trace elements in human nutrition

    International Nuclear Information System (INIS)

    Kosta, L.

    1981-01-01

    New analytical methods based on radiochemical neutron activation analysis were developed for the determination of Sn, V, I and Se at nanogram levels in biological materials, particularly in milk and other foodstuffs. By the application of these and similar methods, results for trace elements in human and cow's milk were collected from which the normal concentration ranges of up to 12 trace elements were established. Significant data on vanadium levels were also collected allowing assessment of the dietary intake and body pool of this element and a reappraisal of its significance in nutrition. Similar data on a smaller scale were also collected for tin. Results were also obtained for several different trace elements in a range of biological reference materials

  10. Laser-fluorescence determination of trace uranium in hot spring water, geothermal water and tap water in Xi'an Lishan region

    International Nuclear Information System (INIS)

    Ma Wenyan; Zhou Chunlin; Han Feng; Di Yuming

    2002-01-01

    Using the Laser-Fluorescence technique, an investigation was made, adopting the standard mix method, on trace uranium concentrations in hot spring water and geothermal water from Lishan region, and in tap water from some major cities in Shanxi province. Totally 40 samples from 27 sites were investigated. Measurement showed that the tap water contains around 10 -6 g/L of uranium, whose concentrations in both hot spring water and geothermal water are 10 -5 g/L. Most of samples are at normal radioactive background level, some higher contents were determined in a few samples

  11. Solvent extraction with thiothenoyltrifluoroacetone and fluorined β-diketones for the determination of metal traces in waters by atomic absorption spectroscopy

    International Nuclear Information System (INIS)

    Jauniaux, M.; Meyer, M. de; Lejeune, W.; Levert, J.M.

    1975-01-01

    A method is described for the determination of metal elements: aluminium, cadmium, copper, iron, lead and zinc as traces in water. The elements are extracted as metal chelates of fluorinated (β-ketones (trifluoracetyl-acetone, thenoyl trifluoroacetone) or thiothenoyl trifluoroacetone with ethyle propionate. They are measured by atomic absorption spectroscopy of the organic extraction. The calibration curves are linear between 0 and 100 μg/l at least. Sensitivities vary from 1 PPB to about 10 PPB according to the metals. The method can be applied for other elements. (author)

  12. Levels of trace metals in water and sediment from Tyume River and ...

    African Journals Online (AJOL)

    Levels of trace metals (Cd, Pb, Co, Zn Cu and Ni) were determined in water and sediment ... mg/l) and Pb (0.021 ± 0.004 to 0.035 ± 0.001 mg/l) were found in the river water, ... Key words: trace metals, water, sediment, farmland, Tyume River

  13. Biomarkers for Ectopic Pregnancy and Pregnancy of Unknown Location

    OpenAIRE

    Senapati, Suneeta; Barnhart, Kurt T.

    2013-01-01

    Early pregnancy failure is the most common complication of pregnancy, and 1–2% of all pregnancies will be ectopic. As one of the leading causes of maternal morbidity and mortality, diagnosing ectopic pregnancy and determining the fate of a pregnancy of unknown location are of great clinical concern. Several serum and plasma biomarkers for ectopic pregnancy have been investigated independently and in combination. The following is a review of the state of biomarker discovery and development for...

  14. Trace elements in the atmosphere over South Africa

    International Nuclear Information System (INIS)

    Wells, R.B.; Van As, D.

    1976-01-01

    Natural sources of trace elements in the atmosphere are suspended soil particles, the evaporation of sea spray and smoke from veld fires. In urban and industrialised areas the main sources are fossil-fuel power plants, metallurgical smelters, blast furnaces, incinerators, automobiles, fossil-fueled locomotives and open fires in the Black townships. Often a source can be recognised by the relative concentrations of particular trace elements. A monitoring programme was established in 1974 by the Air Pollution Research Group of the CSIR and the Isotope and Radiation Division of the Atomic Energy Board in order to study the levels of trace elements in urban areas such as Johannesburg, Cape Town, and Durban, to measure the effects of industrialisation on trace elements levels in developing areas such as Richards Bay and Saldanha Bay and also to determine baseline values in rural areas. Extremely sensitive analytical techniques, e.g. neutron activation and atomic absorption were used for the analyses of filter samples. Methods of sampling and analysis are discussed and the preliminary results of this programme are presented

  15. Application of radio-reagent method in the determination of lead trace amounts

    International Nuclear Information System (INIS)

    Figueiredo, A.M.G.

    1983-01-01

    A radiometric method for trace analysis of lead was established, based on the displacement reaction between lead and the complex cobalt - ethylenediaminetetracetate labelled with 60 Co (Co* - EDTA), which is named radioreagent. The radioactive cobalt displaced by lead is separated from the excess of radioreagent by the solvent extraction technique, using a solution of tetracycline (Tc) in benzyl alcohol. The activity of the extracted cobalt is then measured by means of a single-channel gamma-ray analyser coupled to a NaI (Tl) scintillation detector, the activity being proportional to the lead concentration, in a range from 2.5 to 150 μg. The interference of several elements (V, Th, Sc, Fe, La, Yb, Cu, Cd, Zn, Mn, Ni, Co, Al and Sn) was investigated by means of a previous separation between lead and these interfering elements. The analyses of artificial samples containing lead and the interfering elements gave a yield of 91.1 + - 3.2 %. The detection limit achieved by the method was 3.3 μg of lead. The radioreagent method was applied to lead analysis of samples from IAEA, namely: simulated air filter (Air-3), fresh water (W-3), dried animal blood (A-2) and calcinated animal bone (A-3/1). Lead was also determined in gasoline samples and air samples, these latter collected in the surroundings of the IPEN/CNEN/SP (Brazil). (Author) [pt

  16. Semiclassical structure of trace formulas

    International Nuclear Information System (INIS)

    Littlejohn, R.G.

    1990-01-01

    Trace formulas provide the only general relations known connecting quantum mechanics with classical mechanics in the case that the classical motion is chaotic. In particular, they connect quantal objects such as the density of states with classical periodic orbits. In this paper, several trace formulas, including those of Gutzwiller, Balian and Bloch, Tabor, and Berry, are examined from a geometrical standpoint. New forms of the amplitude determinant in asymptotic theory are developed as tools for this examination. The meaning of caustics in these formulas is revealed in terms of intersections of Lagrangian manifolds in phase space. The periodic orbits themselves appear as caustics of an unstable kind, lying on the intersection of two Lagrangian manifolds in the appropriate phase space. New insight is obtained into the Weyl correspondence and the Wigner function, especially their caustic structures

  17. Determination of traces of fluorine and hydrofluoric acid in the atmosphere

    International Nuclear Information System (INIS)

    Francois, H.; Grand-Clement, A.M.; Faltot, G.

    1963-01-01

    As some publications highlighted hazards related to the presence of dispersed fluorine and hydrofluoric acid in the atmosphere, the authors, after a brief recall of some measurement devices presented in some publications, present an experimental set-up which aims at measuring traces of these compounds in the atmosphere. They notably describe the preparation of a controlled fluorine atmosphere, discuss the efficiency of the absorption-based trap, report the study of the electrolytic analysis cell, discuss its calibration. They also report the study of the influence of temperature and of the presence of disturbing ions

  18. Development of a mass spectrometrical isotope dilution analysis for determination of trace iodine levels and its application for food samples

    International Nuclear Information System (INIS)

    Schindlmeier, W.

    1984-01-01

    A mass spectrometrical isotope dilution procedure for the determination of trace amounts of iodine in various materials was developed using 129 I as indicator isotope, based on the determination of the 129 I/ 127 I isotope relationship. Negative thermionization was used as ionization method. The analysis procedure, which worked with a standard deviation of between 0,1 and 10% (depending on material tested), was used to determine the iodine level of table salt - both iodized and normal salt (3-6 ppm and less than 0,006 ppm respectively), and food samples with an organic matrix. For comparison the iodine levels were also measured with an iodine-selective electrode. Special preparation and separation procedures were done to suit the sample material. A comparison of the levels of iodine concentration in various powdered milks which were measured by international collaborators using varying methods shows the superior reproducibility of the MS-IDA. (RB) [de

  19. Determination of water traces in various organic solvents using Karl Fischer method under FIA conditions.

    Science.gov (United States)

    Dantan, N; Frenzel, W; Küppers, S

    2000-05-31

    Flow injection methods utilising the Karl Fischer (KF) reaction with spectrophotometric and potentiometric detection are described for the determination of the trace water content in various organic solvents. Optimisation of the methods resulted in an accessible (linear) working range of 0.01-0.2% water for many solvents studied with a typical precision of 1-2% R.S.D. Only 50 mul of organic solvent was injected and the sampling frequency was about 120 samples per h. Since the slopes of the calibration curves were different for different solvents appropriate calibration was required. Problems associated with spectrophotometric detection and caused by refractive index changes were pointed out and a nested-loop configuration was proposed to overcome this kind of interference. The potentiometric method with a novel flow-through detector cell was shown to surpass the performance of spectrophotometric detection in any respect. The characteristics of the procedures developed made them well applicable for on-line monitoring of technical solvent distillations in an industrial plant.

  20. Application of neutron activation analysis to trace element determinations in lung samples

    International Nuclear Information System (INIS)

    Rocero, Sizue Ota

    1992-01-01

    The purpose of this work was to apply the instrumental neutron activation analysis method to determine trace elements in lung samples from smokers and non smokers. Samples of lung tissues and lymph nodes from pulmonary hilum analyzed were collected from autopsies by researchers from the Medicine College of the University of Sao Paulo, SP, Brazil. Adequate conditions for preparation and analysis of samples were previously established. The preparation of samples consisted of homogenization, lyophilization and sterilization in 60 Co source. The samples and standards were irradiated in the IEA-R1 reactor under thermal neutron flux of 3.7 x 10 11 n.cm -2 .s -1 for 30 min to determine Cl, K, Mn and Na and for 16 h under flux of 10 19 n.cm -2 .s -1 for the determination of Au, Br, Ce, Co, Cr, Cs, Eu, Fe, Hf, La, Rb, Sb, Sc, Se, Th and Zn. The counting were carried out with a hiperpure (ge) detector connected to a 4096 channels analyzer and a microcomputer. the results obtained for lung sample analyses indicated a good reproducibility of the method for most of the elements determined with relative standard deviations lower than 10.5%. The accuracy of the method was evaluated by analyzing reference materials such as IAEA Animal Muscle H-4, NIST Bovine Liver 1577a, IUPAC Bowen's Kale and NIES Vehicle Exhaust Particulates. The results obtained from these analyzes agreed with the values of the literature for several elements with relative errors less than 20%. Less precise and accurate results were obtained for elements with concentrations at the Mup/Kg levels. Elemental concentrations obtained in the lung tissue analyses were within the range of reference values for normal subjects presented in the literature, except for the Cl concentrations for non smokers, Hf in both groups and Sb for the smokers. By comparing results obtained for lung samples from smokers and non smokers, the concentrations of Ce, Cr and Sb were higher in lungs from smokers and the others elements were

  1. Chinese Unknown Word Recognition for PCFG-LA Parsing

    Directory of Open Access Journals (Sweden)

    Qiuping Huang

    2014-01-01

    Full Text Available This paper investigates the recognition of unknown words in Chinese parsing. Two methods are proposed to handle this problem. One is the modification of a character-based model. We model the emission probability of an unknown word using the first and last characters in the word. It aims to reduce the POS tag ambiguities of unknown words to improve the parsing performance. In addition, a novel method, using graph-based semisupervised learning (SSL, is proposed to improve the syntax parsing of unknown words. Its goal is to discover additional lexical knowledge from a large amount of unlabeled data to help the syntax parsing. The method is mainly to propagate lexical emission probabilities to unknown words by building the similarity graphs over the words of labeled and unlabeled data. The derived distributions are incorporated into the parsing process. The proposed methods are effective in dealing with the unknown words to improve the parsing. Empirical results for Penn Chinese Treebank and TCT Treebank revealed its effectiveness.

  2. TraceContract: A Scala DSL for Trace Analysis

    Science.gov (United States)

    Barringer, Howard; Havelund, Klaus

    2011-01-01

    In this paper we describe TRACECONTRACT, an API for trace analysis, implemented in the SCALA programming language. We argue that for certain forms of trace analysis the best weapon is a high level programming language augmented with constructs for temporal reasoning. A trace is a sequence of events, which may for example be generated by a running program, instrumented appropriately to generate events. The API supports writing properties in a notation that combines an advanced form of data parameterized state machines with temporal logic. The implementation utilizes SCALA's support for defining internal Domain Specific Languages (DSLs). Furthermore SCALA's combination of object oriented and functional programming features, including partial functions and pattern matching, makes it an ideal host language for such an API.

  3. Determination of trace amounts of Brown HT as a food dye by a CPE-scanometry method

    Directory of Open Access Journals (Sweden)

    A. Shokrollahi

    2017-01-01

    Full Text Available In this study, trace amounts of Brown HT were extracted, pre-concentrated and determined by cloud point extraction-scanometry (CPE-scanometry as a simple, fast and inexpensive method. The procedure is based on CPE of Brown HT from an aqueous solution, diluting the extracted surfactant-rich phase with ethanol to 500 μL, transferring the appropriate volume to Plexiglas® cells and scanning the cells. Then, the colour of each cell was analyzed by software written in visual basic (VB 6 into red, green and blue values. Effective parameters for the extraction efficiency, such as the pH of the system, the concentration of surfactant, the equilibration temperature and equilibration time, were investigated and optimized. Under optimal conditions, the calibration curve was linear in the range of 0.06–2.60 mg L−1. The detection limit of the proposed method was 0.04 mg L−1. In addition, the effects of some foreign species, including cations, anions and dyes, were investigated. The method was applied successfully for the determination of Brown HT in some water samples.

  4. Determination of trace mercury in water based on N-octylpyridinium ionic liquids preconcentration and stripping voltammetry.

    Science.gov (United States)

    Li, Zhenhan; Xia, Shanhong; Wang, Jinfen; Bian, Chao; Tong, Jianhua

    2016-01-15

    A novel method for determination of trace mercury in water is developed. The method is performed by extracting mercury firstly with ionic liquids (ILs) and then detecting the concentration of mercury in organic media with anodic stripping voltammetry. Liquid-liquid extraction of mercury(II) ions by four ionic liquids with N-octylpyridinium cations ([OPy](+)) was studied. N-octylpyridinium tetrafluoroborate and N-octylpyridinium trifluoromethylsulfonate were found to be efficient and selective extractant for mercury. Temperature controlled dispersive liquid phase microextraction (TC-DLPME) technique was utilized to improve the performance of preconcentration. After extraction, precipitated IL was diluted by acetonitrile buffer and mercury was detected by differential pulse stripping voltammetry (DPSV) with gold disc electrode. Mercury was enriched by 17 times while interfering ions were reduced by two orders of magnitude in the organic media under optimum condition. Sensitivity and selectivity for electrochemical determination of mercury were improved by using the proposed method. Tap, pond and waste water samples were analyzed with recoveries ranging from 81% to 107% and detection limit of 0.05 μg/L. Copyright © 2015 Elsevier B.V. All rights reserved.

  5. Determination of Heavy and Toxic Trace Elements in Sediments of Qarun Lake Using Instrumental Neutron Activation Analysis Technique

    International Nuclear Information System (INIS)

    Hamed, A.; Abd EI-Samad, M.; Soliman, N.F.

    2011-01-01

    An investigation of certain heavy and toxic trace elements in 15 sediment samples from different areas at Qarun Lake was performed by a neutron activation technique using the neutron irradiation facilities of the Second Egyptian Research Reactor (ETRR-2). The samples together with two sets of gold foils (one bare and the other covered with cadmium) and two Standard Reference Materials IAEA (Soil-7) were irradiated at the core of the reactor in two capsules for 8520 seconds, another two capsules each has two sets of gold foils (one bare and the other covered with cadmium) are used to determine the neutron fluxes around the sediment samples. The gamma-rays of nuclides from the irradiated samples were carried out by means of a well calibrated high resolution HPGe detection system. The concentrations of product nuclides containing in the irradiated samples were determined from the peak counting-rates of the prominent gamma-ray lines for the corresponding nuclides using Single External Comparator Method (k 0 -Standardization Method) which called k 0 -NAA technique. The neutron flux ratios (f) in the same radiation sites of the sediment samples bottles were calculated as well as the cadmium ratios (R e d). MS Excel work books were constructed and used in our calculation. The total contents of As , Ba , Ca ,Co, Cr ,Cs, Eu ,Hf ,Hg,Na ,Ru ,Sc ,Se ,Sm ,Sn ,Sr ,Th ,Rb ,Zn ,and Zr in these samples were measured. The objectives .of this study were evaluated to identify the variations of concentration of some elements that have an impact on environmental pollutions. The results indicated that the concentrations of toxic trace elements of Ba, Cr, Se, Sn, Hg, Sin and Zn may represent pollutions problem

  6. Sensitive determination of trace mercury by UV-visible diffuse reflectance spectroscopy after complexation and membrane filtration-enrichment.

    Science.gov (United States)

    Yin, Changhai; Iqbal, Jibran; Hu, Huilian; Liu, Bingxiang; Zhang, Lei; Zhu, Bilin; Du, Yiping

    2012-09-30

    A simple, sensitive and selective solid phase reflectometry method is proposed for the determination of trace mercury in aqueous samples. The complexation reagent dithizone was firstly injected into the properly buffered solution with vigorous stirring, which started a simultaneous formation of nanoparticles suspension of dithizone and its complexation reaction with the mercury(II) ions to make Hg-dithizone nanoparticles. After a definite time, the mixture was filtered with membrane, and then quantified directly on the surface of the membrane by using integrating sphere accessory of the UV-visible spectrophotometer. The quantitative analysis was carried out at a wavelength of 485 nm since it yielded the largest difference in diffuse reflectance spectra before and after reaction with mercury(II).A good linear correlation in the range of 0.2-4.0 μg/L with a squared correlation coefficient (R(2)) of 0.9944 and a detection limit of 0.12 μg/L were obtained. The accuracy of the method was evaluated by the analysis of spiked mercury(II) concentrations determined using this method along with those determined by the atomic fluorescence mercury vapourmeter and the results obtained were in good agreement. The proposed method was applied to the determination of mercury in tap water and river water samples with the recovery in an acceptable range (95.7-105.3%). Copyright © 2012 Elsevier B.V. All rights reserved.

  7. Trace element distribution in geological crystals

    Energy Technology Data Exchange (ETDEWEB)

    Den Besten, J.L.; Jamieson, D.N.; Weiser, P.S. [Melbourne Univ., Parkville, VIC (Australia). School of Physics

    1996-12-31

    Channelling is a useful microprobe technique for determining the structure of crystals, but until now has not been performed on geological crystals. The composition has been investigated rather than the structure, which can further explain the origin of the crystal and provide useful information on the substitutionality of trace elements. This may then lead to applications of extraction of valuable metals and semiconductor electronics. Natural crystals of pyrite, FeS{sub 2}, which contains a substantial concentration of gold were channeled and examined to identify the channel axis orientation. Rutherford Backscattering (RBS) and Particle Induced X-Ray Emission (PIXE) spectra using MeV ions were obtained in the experiment to provide a comparison of lattice and non-lattice trace elements. 3 figs.

  8. Trace element distribution in geological crystals

    Energy Technology Data Exchange (ETDEWEB)

    Den Besten, J L; Jamieson, D N; Weiser, P S [Melbourne Univ., Parkville, VIC (Australia). School of Physics

    1997-12-31

    Channelling is a useful microprobe technique for determining the structure of crystals, but until now has not been performed on geological crystals. The composition has been investigated rather than the structure, which can further explain the origin of the crystal and provide useful information on the substitutionality of trace elements. This may then lead to applications of extraction of valuable metals and semiconductor electronics. Natural crystals of pyrite, FeS{sub 2}, which contains a substantial concentration of gold were channeled and examined to identify the channel axis orientation. Rutherford Backscattering (RBS) and Particle Induced X-Ray Emission (PIXE) spectra using MeV ions were obtained in the experiment to provide a comparison of lattice and non-lattice trace elements. 3 figs.

  9. Reconstructing Early Industrial Contributions to Legacy Trace Metal Contamination in Southwestern Pennsylvania

    Science.gov (United States)

    Rossi, R.; Bain, D.; Hillman, A. L.; Pompeani, D. P.; Abbott, M. B.

    2015-12-01

    The remobilization of legacy contamination stored in floodplain sediments remains a threat to ecosystem and human health, particularly with potential changes in global precipitation patterns and flooding regimes. Vehicular and industrial emissions are often the dominant, recognized source of anthropogenic trace metal loadings to ecosystems today. However, loadings from early industrial activities are poorly characterized and potential sources of trace metal inputs. While potential trace metal contamination from these activities is recognized (e.g., the historical use of lead arsenate as a pesticide), the magnitude and distribution of legacy contamination is often unknown. This presentation reconstructs a lake sediment record of trace metal inputs from an oxbow lake in Southwestern Pennsylvania. Sediment cores were analyzed for major and trace metal chemistry, carbon to nitrogen ratios, bulk density, and magnetic susceptibility. Sediment trace metal chemistry in this approximately 250 year record (180 cm) record changes in land use and industry both in the 19th century and the 20th century. Of particular interest is early 19th century loadings of arsenic and calcium to the lake, likely attributable to pesticides and lime used in tanning processes near the lake. After this period of tanning dominated inputs, sediment barium concentrations rise, likely reflecting the onset of coal mining operations and resulting discharge of acid mine drainage to surface waters. In the 20th century portion of our record (70 -20 cm), patterns in sediment zinc, cadmium, and lead concentrations are dominated by the opening and closing of the nearby Donora Zinc Works and the American Steel & Wire Works, infamous facilities in the history of air quality regulation. The most recent sediment chemistry records periods include the enactment of air pollution legislation (~ 35 cm), and the phase out of tetraethyl leaded gasoline (~30 cm). Our study documents the impact of early industry in the

  10. Trace Metal Concentrations in Commercially Important Fishes from ...

    African Journals Online (AJOL)

    komla

    Some trace metals such as zinc and copper are important in small quantities for ...... Cameroon: Institut de recherches meddicales et d'etudes des plantes edicinales, ... Determination of Total Cadmium, Zinc, Lead, Copper in Selected Marine ...

  11. Fully-differential spectrophotometry determination of trace thorium in uranium-containing waste water separated by CL-TBP levextrel resin

    International Nuclear Information System (INIS)

    You Jiannan

    2000-01-01

    A method for separation by CL-TBP levextrel resin and determination of trace thorium in uranium-containing waste water by fully-differential spectrophotometry is developed. In 4 mol/L HNO 3 medium, in presence of tartaric acid, CL-TBP levextrel resin is used for adsorption of thorium and separating from other elements. The thorium on the resin is stripped by 4 mol/L HCl, with oxalic acid and urea as screening agent, thorium forms red complex with arsenazo III. The maximum absorption of the complex is at 668 nm, and the molar absorptivity is 1.27 x 10 5 L/(mol·cm) . The complex can be steady for 2.5 h. By regulating micro-current of differential spectrophotometry, the method can realize determination with high precision. Sensitivity of this method increase 10 times than usual spectrophotometry. The relative standard deviation is better than +- 5% and recovery of thorium is 99%-107%

  12. Determination of trace zinc in seawater by coupling solid phase extraction and fluorescence detection in the Lab-On-Valve format.

    Science.gov (United States)

    Grand, Maxime M; Chocholouš, Petr; Růžička, Jarda; Solich, Petr; Measures, Christopher I

    2016-06-07

    By virtue of their compactness, long-term stability, minimal reagent consumption and robustness, miniaturized sequential injection instruments are well suited for automation of assays onboard research ships. However, in order to reach the sensitivity and limit of detection required for open-ocean determinations of trace elements, it is necessary to preconcentrate the analyte prior its derivatization and subsequent detection by fluorescence. In this work, a novel method for the determination of dissolved zinc (Zn) at subnanomolar levels in seawater is described. The proposed method combines, for the first time, automated matrix removal, extraction of the target element, and fluorescence detection within a miniaturized flow manifold, based on the Lab-On-Valve (LOV) concept. The key feature of the microfluidic manipulation of the sample is flow programming, designed to pass sample through a mini-column where the target analyte and other complexable cations are retained, while the seawater matrix is washed out. Next, zinc is eluted and merged with a Zn selective fluorescent probe (FluoZin-3) at the confluence point of the LOV central channel using two high-precision stepper motor driven pumps that are operated in concert. Finally, the thus formed Zn complex is transported to the LOV flow cell for selective fluorescence measurement. This work describes the characterization and optimization of the method including Solid Phase Extraction using the Toyopearl AF-Chelate-650M resin, and detailed assay protocol controlled by a commercially available software and instrument. The proposed method features a LOD of 0.02 nM, high precision (seawater reference standards and comparison with ICP-MS determinations on seawater samples collected in the upper 1300 m of the subtropical south Indian Ocean. This work confirms that integration of sample pretreatment with optical detection in the LOV format offers a widely applicable approach to trace analysis of seawater. Copyright © 2016

  13. Utility of solid phase spectrophotometry for the modified determination of trace amounts of cadmium in food samples.

    Science.gov (United States)

    Amin, Alaa S; Gouda, Ayman A

    2012-05-01

    A modified selective, highly sensitive and accurate procedure for the determination of trace amounts of cadmium which reacts with 1-(2-benzothiazolylazo)-2-hydroxy-3-naphthoic acid (BTAHNA) to give a deep violet complex with high molar absorptivity (7.05×10(6)Lmol(-1) cm(-1), 3.92×10(7)Lmol(-1)cm(-1), 1.78×10(8)Lmol(-1)cm(-1), and 4.10×10(8)Lmol(-1)cm(-1)), fixed on a Dowex 1-X8 type anion-exchange resin for 10mL, 100mL, 500mL, and 1000mL, respectively. Calibration is linear over the range 0.2-3.5μgL(-1) with RSD of ⩽1.14% (n=10). The detection and quantification limits were calculated. Increasing the sample volume can enhance the sensitivity. The method has been successfully applied for the determination of Cd(II) in food samples, water samples and some salts samples without interfering effect of various cations and anions. Copyright © 2011 Elsevier Ltd. All rights reserved.

  14. Highly sensitive sorption-luminescence determination of trace europium with preconcentration on silica chemically modified with iminodiacetic acid

    International Nuclear Information System (INIS)

    Voronina, R.D.; Zorov, N.B.

    2007-01-01

    Features of a sorption-luminescence method for the determination of trace europium were studied. The method includes the preliminary sorption of europium at pH 7.1 from solutions with silica chemically modified with iminodiacetic acid, the subsequent treatment of the sorbent with 2-thenoyltrifluoroacetone at pH 8.0, and the measurement of the intensity of luminescence of the surface three-component europium complex at 613 nm. The effect of moisture as the quencher of luminescence of the surface europium complex was studied, and techniques for its removal were proposed. Sorption in the static mode provides the detection limit of europium of 7 x 10 -5 g/ml. The calibration plot is linear in the range of two orders of magnitude of europium concentration in solutions. The relative standard deviation in the determination of 1.5 x 10 -2 μg/ml europium is 5%. In the dynamic mode of sorption from 1000 ml of an analyzed solution with the use of sorption-desorption, the detection limit of europium of 8 x 10 -7 μg/ml was attained [ru

  15. A new method for the determination of NO2 traces using isotope dilution and mass spectrometry analysis

    International Nuclear Information System (INIS)

    Stevens, C.; Barat, F.; Nguyen Nghi, H.

    1975-01-01

    A new method for the determination of NO 2 traces, in the order of 1ppb (10 -9 ), in atmosphere and stratosphere is described. The method consists in an isotope dilution technique using 15 NO 2 , followed by the reduction of NO 2 to N 2 and a mass spectrometry analysis. A known amount of 15 NO 2 is added to the air samples. Then, NO 2 is separated from H 2 O, HNO 3 , CO 2 and N 2 O and transferred to a SiO 2 reactor by trapping at -196 deg C. In the reactor NO 2 is reduced to N 2 by reaction with electrolytic Cu heated at 580 deg C. The mass 29/mass 30 ratio corresponding to 15 N 14 N and 15 N 15 N is determined by mass spectrometry. The sensitivity of the method depends on the contamination introduced during the analysis of the sample (reagents, separation and measuring devices). The contamination is reproducible and in the order of 4.5+-0.5 10 -2 mm 3 N 2 [fr

  16. Development of a procedure for the multi-element determination of trace elements in wine by ICP-MS

    Energy Technology Data Exchange (ETDEWEB)

    Castineira, M.M.; Brandt, R.; von Bohlen, A.; Jakubowski, N. [Institut fuer Spektrochemie und Angewandte Spektroskopie e.V., Dortmund (Germany)

    2001-07-01

    An inductively coupled plasma mass spectrometric (ICP-MS) procedure has been developed for the determination of trace elements in wine. The procedure consists in simple 1+1 dilution of the wine and semi-quantitative analysis (without external calibration) using In as internal standard. Thirty-one elements at concentrations ranging from 0.1 mg mL{sup -1} to 0.5 ng mL{sup -1} can be determined by ICP-MS analysis with and without digestion. It was investigated whether a matrix effect observed for EtOH in the wine matrix can be overcome by application of a micro-concentric nebulizer with a membrane desolvator (MCN 6000). The results obtained for the MCN 6000 are compared with those obtained by use of a conventional Meinhard nebulizer. It is shown that the observed matrix effect can only be compensated by use of an internal standard for the Meinhard nebulizer, but not for the MCN 6000. Results for ICP-MS are compared with those obtained by total reflection X-ray fluorescence spectrometry (TXRF). (orig.)

  17. Preconcentration of trace elements by using 1-(2-Pyridylazo-2-naphthol functionalized Amberlite XAD-1180 resin and their determination by FAAS

    Directory of Open Access Journals (Sweden)

    Tokalioglu Serife

    2006-01-01

    Full Text Available In this study, Amberlite XAD-1180 resin functionalized by 1-(2-pyridylazo-2-naphthol (PAN was synthesized and the resulting resin was used for preconcentration of Cr(III, Mn(II, Fe(III, Ni(II, Cu(II, Cd(II and Pb(II elements present at trace levels in different matrices. For this purpose, the copolymer was nitrated, reduced to the corresponding amine, converted to the diazonium salt with nitrite and reacted with PAN to produce the XAD-1180-PAN chelating resin. For the described method, the effect of some analytical parameters, such as pH, sample volume, resin amount, flow rates of uptake and stripping, volume and type of eluent, on the recovery of the trace elements was investigated. The metals retained on the XAD-1180-PAN resin were eluted by 2 mol L-1 HNO3. The influence of matrix ions, i.e., Na(I, K(I, Ca(II and Mg(II, on the recovery of trace elements was also examined by using the developed method when they occurred both individually and together. The repeatability of the method at the optimum conditions determined experimentally was investigated. The recovery values for all the elements, except for Cr(III, were found to be >92% and the relative standard deviation was <8.5%. The 3s/b detection limits for Cr(III, Mn(II, Fe(III, Ni(II, Cu(II, Cd(II and Pb(II were found to be 4.1, 0.13, 2.7, 1.2, 0.19, 0.06 and 0.13 µg L-1, respectively. The developed method was utilized for preconcentration and determination of Mn(II, Fe(III, Ni(II, Cu(II, Cd(II and Pb(II in tap water, rain water, and stream water, and of Ni(II, Cd(II and Pb(II in a certified reference material (RM 8704 Buffalo river sediment by flame atomic absorption spectrometry (FAAS.

  18. The use of chelating ion exchanger in conjunction with radioisotope X-ray spectrometry for determination of trace amounts of metals in water

    International Nuclear Information System (INIS)

    Holynska, B.

    1974-01-01

    The chelating ion exchange resin Chelex-100 has been applied for collection of trace amounts of several metal ions from water solutions. The kinetics of the exchange reaction has been measured, as well as the influence of pH of the solution and Ca or Na ion concentrations on the metal collection. The radioisotope X-ray fluorescence method has been applied for determination of metal ions absorbed in the resin. The estimated limit of determination is 0.01 ppm for Fe 3+ , Zn 2+ , Cu 2+ , Hg 2+ , Pb 2+ and Cd 2+ . Total error (1 s) of the method varied from 3 to 15% depending on the metal concentration. (author)

  19. The use of a chelating resin column for preconcentration of trace elements from sea-water in their determination by neutron-activation analysis

    International Nuclear Information System (INIS)

    Lee, C.; Kim, N.B.; Lee, I.C.; Chung, K.S.

    1977-01-01

    A Chelex-100 resin column has been employed for the preliminary concentration of trace elements in water samples before their determination by neutron-activation analysis. The column filled with a 1 : 1 mixture of the resin (50 to 100 mesh) and Pyrex glass powder of the same mesh size, is shown to maintain a constant flow-rate and give reproducible results. By a combination of preconcentration and neutron-activation analysis it is possible to determine Ba, Ca, Cd, Ce, Co, Cr, Cu, Fe, La, Mg, Mn, Sc, U, V and Zn in sea-water and/or fresh water simultaneously at the parts per milliard level. (author)

  20. Trace elements determination in human hair

    International Nuclear Information System (INIS)

    Carrion, Jose

    1995-01-01

    Concentrations of Cu, Zn, Pb, Mg, Ca, Na, K, Mn, Cr, Ni, Co, V, Cd and Al, in human hair sampled from 23 young men during 24 months were determined by atomic absorption spectroscopy. Additional determination of mercury and volatile elements were made by using accessory MHS-10. Statistical treatment of data is presented for each person and element. The pre-treatment of hair carried out with an organic solvent to remove the superficial pollutants is explained. (The author)

  1. Trace analysis

    International Nuclear Information System (INIS)

    Warner, M.

    1987-01-01

    What is the current state of quantitative trace analytical chemistry? What are today's research efforts? And what challenges does the future hold? These are some of the questions addressed at a recent four-day symposium sponsored by the National Bureau of Standards (NBS) entitled Accuracy in Trace Analysis - Accomplishments, Goals, Challenges. The two plenary sessions held on the first day of the symposium reviewed the history of quantitative trace analysis, discussed the present situation from academic and industrial perspectives, and summarized future needs. The remaining three days of the symposium consisted of parallel sessions dealing with the measurement process; quantitation in materials; environmental, clinical, and nutrient analysis; and advances in analytical techniques

  2. Cloud point extraction-flame atomic absorption spectrometry for pre-concentration and determination of trace amounts of silver ions in water samples

    Directory of Open Access Journals (Sweden)

    Xiupei Yang

    2017-03-01

    Full Text Available A cloud point extraction (CPE method was used as a pre-concentration strategy prior to the determination of trace levels of silver in water by flame atomic absorption spectrometry (FAAS The pre-concentration is based on the clouding phenomena of non-ionic surfactant, triton X-114, with Ag (I/diethyldithiocarbamate (DDTC complexes in which the latter is soluble in a micellar phase composed by the former. When the temperature increases above its cloud point, the Ag (I/DDTC complexes are extracted into the surfactant-rich phase. The factors affecting the extraction efficiency including pH of the aqueous solution, concentration of the DDTC, amount of the surfactant, incubation temperature and time were investigated and optimized. Under the optimal experimental conditions, no interference was observed for the determination of 100 ng·mL−1 Ag+ in the presence of various cations below their maximum concentrations allowed in this method, for instance, 50 μg·mL−1 for both Zn2+ and Cu2+, 80 μg·mL−1 for Pb2+, 1000 μg·mL−1 for Mn2+, and 100 μg·mL−1 for both Cd2+ and Ni2+. The calibration curve was linear in the range of 1–500 ng·mL−1 with a limit of detection (LOD at 0.3 ng·mL−1. The developed method was successfully applied for the determination of trace levels of silver in water samples such as river water and tap water.

  3. Determination of lead element trace in some Syrian cigarettes and Its mixtures using voltammetric method on HMDE

    International Nuclear Information System (INIS)

    Nasser, H.; Kabass, H.

    2010-01-01

    This study aims for estimating of trace for these elements in various brands of Syrian Cigarettes and its mixtures, by using voltammetric method (HMDE) hanging mercury drop elec trod. This method is first used to determined Syrian Cigarettes brand and its mixtures, during this study it was found that we can use it easily with low commission, high sensitivity and accurate results comparing with others studies. We prepare the samples by using reference methods. The samples were collected during two times in one year from the same kinds of samples. We noticed that the high concentrations was (3.795μg/g) in Gitanes samples, and the low concentrations in shame samples was (0.37 μg/g). This study refers that there is different concentrations of lead element in this samples.(author)

  4. Using the ion microprobe mass analyser for trace element analysis

    International Nuclear Information System (INIS)

    Schilling, J.H.

    1978-01-01

    Most techniques for the analysis of trace elements are capable of determining the concentrations in a bulk sample or solution, but without reflecting their distribution. In a bulk analysis therefore elements which occur in high concentration in a few precipitates would still be considered trace elements even though their local concentration greatly exceed the normally accepted trace elements concentration limit. Anomalous distribution is also shown by an oxide layer, a few hundred Angstrom thick, on an aluminium sample. A low oxide concentration would be reported if it were included in the bulk analysis, which contradicts the high surface concentration. The importance of a knowledge of the trace element distribution is therefore demonstrated. Distributional trace element analysis can be carried out using the ion microprobe mass analyser (IMMA). Since the analytical technique used in this instrument, namely secondary ion mass spectrometry (SIMS), is not universally appreciated, the instrument and its features will be described briefly followed by a discussion of quantitative analysis and the related subjects of detection limit and sample consumption. Finally, a few examples of the use of the instrument are given

  5. Rapid determination of trace phosphorus, sulfur, chlorine, bromine and iodine by energy dispersive X-ray fluorescence analysis with monochromatic excitations

    International Nuclear Information System (INIS)

    Wakisaka, Tatsushi; Morita, Naoki; Hirabayashi, Tadashi; Nakahara, Taketoshi

    1998-01-01

    A useful and rapid procedure is described for the determination of trace phosphorus, sulfur, chlorine, bromine, and iodine by means of an energy dispersive X-ray fluorescence spectrometer (EDXRF) with monochromatic excitations. Using monochromatic excitations, the detection limits for phosphorus, sulfur, chlorine (Cr-Kα, 5.41 keV), bromine (Mo-Kα, 17.44 keV), and iodine (W-continuum, 40 keV) were found to be 4.6, 1.7, 0.7, 0.09 and 0.5 μg g -1 , respectively. The relative standard deviations in five replicate measurements were 0.9-1.3%. The proposed method was applied to the direct determination of sulfur in the NIST Residual Fuel Oil, and others. The results obtained by the proposed method were in good agreement with the certified values. Bromine in a seawater sample, as well as iodine and bromine in a brine sample were determined by the proposed method. The obtained results were in good agreement with those obtained by ion chromatography. (author)

  6. World-wide and regional intercomparison for the determination of trace elements in polluted marine sediment IAEA-356. Report no.56

    Energy Technology Data Exchange (ETDEWEB)

    Horvat, M; Mee, L D; Oregioni, B [International Atomic Energy Agency, Marine Environment Laboratory, Monaco (Monaco)

    1994-09-01

    The accurate and precise determination of trace elements in marine sediment samples is an important aspect of geochemical marine pollution studies and for assessing the levels and pathways of marine pollutants. Past intercomparison exercise conducted by the Marine Environment Laboratory of IAEA (formerly the International Laboratory of Marine Radioactivity) has focused upon the near shore sediment (1) and deep sea marine sediment (2) where trace levels of elements was rather low. The present intercomparison exercise on sediment taken from a polluted coastal lagoon was designed in order to fulfill the increased demand for certified reference materials of various origin and the number of parameters that should be studied. Additionally, different instrumental techniques, both nuclear and non-nuclear, were compared, and evaluated. By statistically examining the data from this study, the material can be certified for future use as a reference material. The current exercise was designed not only to test the intercomparability of different instrumental techniques, but also to evaluate the effectiveness of different procedures for sample digestion. Participants were invited to perform 'total' analyses involving, except in the case of neutron activation analysis, a simple partial extraction with 1M hydrochloric acid (2 hours, room temperature). This partial dissolution had a twofold purpose: (i) to differentiate between instrumental (plus contamination during work-up) errors and those resulting from method-specific (matrix) effects; and (ii) to evaluate a simple screening test for the more labile ('easily leached') fraction of trace elements of particular interest to environmental chemists. The present report presents the entire experimental data set and a statistical evaluation of the results for each parameter.

  7. Effects of psilocybin on hippocampal neurogenesis and extinction of trace fear conditioning.

    Science.gov (United States)

    Catlow, Briony J; Song, Shijie; Paredes, Daniel A; Kirstein, Cheryl L; Sanchez-Ramos, Juan

    2013-08-01

    Drugs that modulate serotonin (5-HT) synaptic concentrations impact neurogenesis and hippocampal (HPC)-dependent learning. The primary objective is to determine the extent to which psilocybin (PSOP) modulates neurogenesis and thereby affects acquisition and extinction of HPC-dependent trace fear conditioning. PSOP, the 5-HT2A agonist 25I-NBMeO and the 5-HT2A/C antagonist ketanserin were administered via an acute intraperitoneal injection to mice. Trace fear conditioning was measured as the amount of time spent immobile in the presence of the conditioned stimulus (CS, auditory tone), trace (silent interval) and post-trace interval over 10 trials. Extinction was determined by the number of trials required to resume mobility during CS, trace and post-trace when the shock was not delivered. Neurogenesis was determined by unbiased counts of cells in the dentate gyrus of the HPC birth-dated with BrdU co-expressing a neuronal marker. Mice treated with a range of doses of PSOP acquired a robust conditioned fear response. Mice injected with low doses of PSOP extinguished cued fear conditioning significantly more rapidly than high-dose PSOP or saline-treated mice. Injection of PSOP, 25I-NBMeO or ketanserin resulted in significant dose-dependent decreases in number of newborn neurons in hippocampus. At the low doses of PSOP that enhanced extinction, neurogenesis was not decreased, but rather tended toward an increase. Extinction of "fear conditioning" may be mediated by actions of the drugs at sites other than hippocampus such as the amygdala, which is known to mediate the perception of fear. Another caveat is that PSOP is not purely selective for 5-HT2A receptors. PSOP facilitates extinction of the classically conditioned fear response, and this, and similar agents, should be explored as potential treatments for post-traumatic stress disorder and related conditions.

  8. Trace elements in sera of patients with hepatitis B: Determination and analysis

    Science.gov (United States)

    Saod, Wahran M.; Darwish, Nadiya T.; Zaidan, Tahseen A.; Alfalujie, Abdul Wahab A.

    2018-04-01

    Chronic Hepatitis B (HBV) is the leading cause of morbidity and mortality worldwide with about 248 million people having HBV infection. Trace elements e.g. copper (Cu), zinc (Zn), selenium (Se) and iron (Fe) are constituent components of many metal proteins and metalloenzymes in human sera. Therefore, the ratios of these trace elements in human sera are often stated to be a good marker for diagnosing various diseases including HBV. The aims of this study are: to compare the level of trace elements in sera of patients infected with HBV and healthy participants, and to evaluate the efficiency of analytical techniques (e.g. Inductively Coupled Plasma-Mass spectrometry (ICP-MS), Atomic Absorption Spectroscopy (hydride generation) (AAS) and Graphite Furnace Atomic Absorption Spectroscopy (GFAAS) that are currently used to detect Fe and Se elements in Patients' human sera. The findings of this study show that the concentration range of copper element between (132.80±28.64 µg/dl) to (105.66±23.20 µg/dl) was significantly higher in HBV infected patients as compared to those in healthy controls (91.27±9.20 µg/dl). Iron concentration range between (206.64±61.60 µg/l) to (170.00±36.71 µg/l) was significantly higher in HBV infected patients as compared to those in healthy controls (158.00±15.13 µg/l). However, patients with HBV had significantly lower serum concentrations of zinc with a concentration range between (111.64±20.90 µg/dl) to (99.25±24.06 µg/dl) as compared to those in healthy controls (113.44±16.38 µg/dl). While selenium concentration range between (64.39±7.39 µg/l) to (51.10±4.96 µg/l) was significantly lower in HBV infected patients as compared to those in healthy controls (67.68±7.60) (μg/l). Moreover, the results of this study suggest that (AAS) technique was the most accurate method to measure the concentration of selenium element, while (UV and ICP-MS) analytical techniques have the same efficiency in measuring the iron concentration.

  9. Trace element analysis in rheumatoid arthritis under chrysotherapy

    International Nuclear Information System (INIS)

    Lecomte, R.; Paradis, P.; Monaro, S.; Barrette, M.; Lamoureux, G.; Menard, H.A.

    1981-01-01

    Proton induced X-ray emission (PIXE) analysis is used to measure trace element concentrations in blood serum from patients with rheumatoid arthritis. Initially trace element contaminations in blood-collecting and storing devices are determined. Then mean values and nyctemeral cycles are measured both in normal subjects and patients with rheumatoid arthritis and other similar pathologies. Abnormal concentrations of Cu and Zn and anomalies in the nyctemeral cycle are found in the patients. In the second phase of the project, the special case of chrysotherapeutically treated (gold salt treatment) rheumatoid arthritis patients is studied for extended periods of time (up to 53 weeks). (orig.)

  10. Trace element analysis in liquids by proton induced x-ray emission

    International Nuclear Information System (INIS)

    Deconninck, G.

    Proton induced x-ray emission (PIXE) from liquid has been developed for quantitative and simultaneous analysis of trace elements. Liquid drops and trickles are bombarded at atmospheric pressure, x-rays are detected in a non dispersive Si(Li) solid state detector. Absolute determinations are made by comparison with standard solutions. Detection limits in a 5 minutes run are in the ppm range for a single drop (0.05 ml). The application of this technique to the determination of trace elements in biological liquids is investigated (Cr, Mn, Fe, Co, Ni, Cu, Zn, in plant extracts, haemocyanine, albumins...). (author)

  11. Known Unknowns in Judgment and Choice

    OpenAIRE

    Walters, Daniel

    2017-01-01

    This dissertation investigates how people make inferences about missing information. Whereas most prior literature focuses on how people process known information, I show that the extent to which people make inferences about missing information impacts judgments and choices. Specifically, I investigate how (1) awareness of known unknowns affects overconfidence in judgment in Chapter 1, (2) beliefs about the knowability of unknowns impacts investment strategies in Chapter 2, and (3) inferences...

  12. Flow-through solid-phase based optical sensor for the multisyringe flow injection trace determination of orthophosphate in waters with chemiluminescence detection

    International Nuclear Information System (INIS)

    Morais, Ines P.A.; Miro, Manuel; Manera, Matias; Estela, Jose Manuel; Cerda, Victor; Souto, M. Renata S.; Rangel, Antonio O.S.S.

    2004-01-01

    In this work, a novel flow-through solid-phase based chemiluminescence (CL) optical sensor is described for the trace determination of orthophosphate in waters exploiting the multisyringe flow injection analysis (MSFIA) concept with multicommutation. The proposed time-based injection flow system relies upon the in-line derivatisation of the analyte with ammonium molybdate in the presence of vanadate, and the transient immobilisation of the resulting heteropolyacid in a N-vinylpyrrolidone/divinylbenzene copolymer packed spiral shape flow-through cell located in front of the window of a photomultiplier tube. The simultaneous injection of well-defined slugs of luminol in alkaline medium and methanol solution towards the packed reactor is afterwards performed by proper switching of the solenoid valves. Then, the light emission from the luminol oxidation by the oxidant species retained onto the sorbent material is readily detected. At the same time, the generated molybdenum-blue compound is eluted by the minute amount of injected methanol, rendering the system prepared for a new measuring cycle. Therefore, the devised sensor enables the integration of the solid-phase CL reaction with elution and detection of the emitted light without the typical drawbacks of the molybdenum-blue based spectrophotometric procedures regarding the excess of molybdate anion, which causes high background signals due to its self-reduction. The noteworthy features of the developed CL-MSFIA system are the feasibility to accommodate reactions with different pH requirements and the ability to determine trace levels of orthophosphate in high silicate content samples (Si/P ratios up to 500). Under the optimised conditions, a dynamic linear range from 5 to 50 μg P l -1 for a 1.8 ml sample, repeatability better than 3.0% and a quantification limit of 4 μg P l -1 were attained. The flowing stream system handles 11 analysis h -1 and has been successfully applied to the determination of trace levels of

  13. Traces of Drosophila Memory

    Science.gov (United States)

    Davis, Ronald L.

    2012-01-01

    Summary Studies using functional cellullar imaging of living flies have identified six memory traces that form in the olfactory nervous system after conditioning with odors. These traces occur in distinct nodes of the olfactory nervous system, form and disappear across different windows of time, and are detected in the imaged neurons as increased calcium influx or synaptic release in response to the conditioned odor. Three traces form at, or near acquisition and co-exist with short-term behavioral memory. One trace forms with a delay after learning and co-exists with intermediate-term behavioral memory. Two traces form many hours after acquisition and co-exist with long-term behavioral memory. The transient memory traces may support behavior across the time-windows of their existence. The experimental approaches for dissecting memory formation in the fly, ranging from the molecular to the systems, make it an ideal system for dissecting the logic by which the nervous system organizes and stores different temporal forms of memory. PMID:21482352

  14. LA-ICP-MS for Trace Analysis of Long-Lived Radionuclides in Solid Non-conducting Radioactive Waste Samples

    International Nuclear Information System (INIS)

    Becker, J.S.; Gastel, M.; Tenzler, D.; Dietze, H.J.

    1999-01-01

    The characterization of radioactive waste materials from nuclear reactors for recycling and final storage requires fast, sensitive and precise analytical methods, which are able to determine long-lived radionuclidic ultra traces in a short time. For the determination of long-lived α and β ray-emitting nuclides besides the classical radiochemical methods which are mostly include time-consuming radiochemical separation procedures, to an increasing extent inductively coupled plasma mass spectrometry (ICP-MS) has been used successfully as a powerful trace, ultra trace and isotopic analytical method for the determination of long-lived radionuclides in aqueous solutions [1-3

  15. Structure-based inference of molecular functions of proteins of unknown function from Berkeley Structural Genomics Center

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Sung-Hou; Shin, Dong Hae; Hou, Jingtong; Chandonia, John-Marc; Das, Debanu; Choi, In-Geol; Kim, Rosalind; Kim, Sung-Hou

    2007-09-02

    Advances in sequence genomics have resulted in an accumulation of a huge number of protein sequences derived from genome sequences. However, the functions of a large portion of them cannot be inferred based on the current methods of sequence homology detection to proteins of known functions. Three-dimensional structure can have an important impact in providing inference of molecular function (physical and chemical function) of a protein of unknown function. Structural genomics centers worldwide have been determining many 3-D structures of the proteins of unknown functions, and possible molecular functions of them have been inferred based on their structures. Combined with bioinformatics and enzymatic assay tools, the successful acceleration of the process of protein structure determination through high throughput pipelines enables the rapid functional annotation of a large fraction of hypothetical proteins. We present a brief summary of the process we used at the Berkeley Structural Genomics Center to infer molecular functions of proteins of unknown function.

  16. Calibration of detectors type CR-39 for methodology implementation for Radon-222 determination in CRCN-NE, Brazil

    International Nuclear Information System (INIS)

    Silva, Karolayne E.M. da; Santos, Mariana L. de O.; Amaral, Déric S. do; Vilela, Eldice C.; França, Elvis J. de; Hazin, Clovis A.; Farias, Emerson E.G. de

    2017-01-01

    Radon-222 is a radioactive gas, a product of the decay of uranium-238, which emits alpha particles and represents more than 50% of the dose of natural radiation received by the population. Therefore, monitoring of this gas is essential. For indoor measurement, solid state detectors can be used, the most common of which is CR-39. For monitoring using CR-39, alpha particles, generated by radon-222 and the daughter radionuclides, strike the surface of the detector and generate traces. To relate the trace density per exposure area in environments with unknown activity concentration, it is necessary to determine the calibration factor. The objective of this study was to calibrate CR-39 type detectors for the implementation of the radon determination methodology in Centro Regional de Ciencias Nucleares do Nordeste - CRCN-NE of Brazilian Nuclear Energy Commission - CNEN. In order to determine the CR-39 calibration factor, 19 exposures of the detectors were performed in the CRCN-NE calibration chamber (RN1-CRCN) at an activity of 5.00 kBq m -3 , with the exposure time varying from 24 to 850 hours. For the detection of the detectors, sodium hydroxide was used in a thermostat bath at 90 ° C for 5 hours. The count of number of traits per unit of field was performed with the aid of optical microscopy with an increase of 100 times, being read 30 fields per dosimeters. As a result, the calibration factor was obtained, and the linear response of the trace density as a function of exposure was observed. The results allow the use of CR-39 in the determination of radon-222 by CRCN-NE

  17. Direct determination of trace rare earth elements in ancient porcelain samples with slurry sampling electrothermal vaporization inductively coupled plasma mass spectrometry

    International Nuclear Information System (INIS)

    Xiang Guoqiang; Jiang Zucheng; He Man; Hu Bin

    2005-01-01

    A method for the direct determination of trace rare earth elements in ancient porcelain samples by slurry sampling fluorinating electrothermal vaporization inductively coupled plasma mass spectrometry was developed with the use of polytetrafluoroethylene as fluorinating reagent. It was found that Si, as a main matrix element in ancient porcelain sample, could be mostly removed at the ashing temperature of 1200 deg. C without considerable losses of the analytes. However, the chemical composition of ancient porcelain sample is very complicated, which makes the influences resulting from other matrix elements not be ignored. Therefore, the matrix effect of ancient porcelain sample was also investigated, and it was found that the matrix effect is obvious when the matrix concentration was larger than 0.8 g l -1 . The study results of particle size effect indicated that when the sample particle size was less than 0.057 mm, the particle size effect is negligible. Under the optimized operation conditions, the detection limits for rare earth elements by fluorinating electrothermal vaporization inductively coupled plasma mass spectrometry were 0.7 ng g -1 (Eu)-33.3 ng g -1 (Nd) with the precisions of 4.1% (Yb)-10% (La) (c = 1 μg l -1 , n = 9). The proposed method was used to directly determine the trace rare earth elements in ancient porcelain samples produced in different dynasty (Sui, Ming and Qing), and the analytical results are satisfactory

  18. Determination of trace elements in some fruits collected in Vietnam and Korea by neutron activation analysis on Dalat and HANARO research reactors

    International Nuclear Information System (INIS)

    Nguyen Thi Sy; Ho Manh Dung; Ho Van Doanh; Tran Quang Thien; Chung Yong-Sam

    2015-01-01

    The k_0-based neutron activation analysis (k_0-NAA) has been applied for determination of trace multi-element in 5 fruits: orange, tomato, persimmon, pear and apple. The samples were collected in Vietnam and Korea, and dried-frozen in laboratory at a temperature of -65"oC, weighed approximately 50 mg or 100 mg each sample, and put in clean polyethylene bags for short and long time irradiations, respectively. The NIST-1547 (Peach Leaves) and IAEA-V-10 (Hay Powder) were used for the purpose of quality control. Both analytical and standard samples were irradiated in the 500 kW Dalat research reactor (Vietnam) and the 20 MW HANARO research reactor (Korea). Concentration of 16 elements: Al, As, Au, Br, Ca, Cl, Co, Eu, Fe, K, La, Mg, Mn, Na, Rb and Zn were determined. By comparison the concentrations of trace elements in the investigated Vietnam and Korea fruits, revealed that they are mostly similar between two places. However, the Ca concentration in orange from Vietnam was approximately 2.5 times higher than that one from Korea, whereas the Ca concentration in pear from Vietnam was approximately 21 times lower than that one from Korea. The Mn concentrations in all of fruits that collected in Vietnam were mostly higher than those collected in Korea, ranging between 1.4 to 2.2 times. (author)

  19. Trace elements distribution in environmental compartments

    Energy Technology Data Exchange (ETDEWEB)

    Queiroz, Juliana C. de; Peres, Sueli da Silva; Godoy, Maria Luiza D.P., E-mail: suelip@ird.gov.br [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2017-11-01

    Trace elements term defines the presence of low concentrations metals at environment. Some of them are considered biologically essential, as Co, Cu and Mn. Others can cause detriment to environment and human health, as Pb, Cd, Hg, As, Ti and U. A large number of them have radioactive isotopes, implying the evaluation of risks for human health should be done considering the precepts of environmental radiological protection. The ecosystem pollution with trace elements generates changes at the geochemistry cycle of these elements and in environmental quality. Soils have single characteristics when compared with another components of biosphere (air, water and biota), cause they introduce themselves not only as a drain towards contaminants, but also as natural buffer that control the transport of chemical elements and other substances for atmosphere, hydrosphere and biota. The main purpose of environmental monitoring program is to evaluate the levels of contaminants in the various compartments of the environment: natural or anthropogenic, and to assess the contribution of a potential contaminant source on the environment. Elemental Composition for the collected samples was determined by inductively coupled plasma mass spectroscopy. The main objective of this work was to evaluate the map baseline of concentration of interest trace elements in environmental samples of water, sediment and soil from Environmental Monitoring Program of Instituto de Radioprotecao e Dosimetria (IRD). The samples were analyzed using an inductively coupled plasma mass spectrometer (ICP-MS) at IRD. >From the knowledge of trace elements concentrations, could be evaluated the environmental quality parameters at the studied ecosystems. The data allowed evaluating some relevant aspects of the study of trace elements in soil and aquatic systems, with emphasis at the distribution, concentration and identification of main anthropic sources of contamination at environment. (author)

  20. Trace elements distribution in environmental compartments

    International Nuclear Information System (INIS)

    Queiroz, Juliana C. de; Peres, Sueli da Silva; Godoy, Maria Luiza D.P.

    2017-01-01

    Trace elements term defines the presence of low concentrations metals at environment. Some of them are considered biologically essential, as Co, Cu and Mn. Others can cause detriment to environment and human health, as Pb, Cd, Hg, As, Ti and U. A large number of them have radioactive isotopes, implying the evaluation of risks for human health should be done considering the precepts of environmental radiological protection. The ecosystem pollution with trace elements generates changes at the geochemistry cycle of these elements and in environmental quality. Soils have single characteristics when compared with another components of biosphere (air, water and biota), cause they introduce themselves not only as a drain towards contaminants, but also as natural buffer that control the transport of chemical elements and other substances for atmosphere, hydrosphere and biota. The main purpose of environmental monitoring program is to evaluate the levels of contaminants in the various compartments of the environment: natural or anthropogenic, and to assess the contribution of a potential contaminant source on the environment. Elemental Composition for the collected samples was determined by inductively coupled plasma mass spectroscopy. The main objective of this work was to evaluate the map baseline of concentration of interest trace elements in environmental samples of water, sediment and soil from Environmental Monitoring Program of Instituto de Radioprotecao e Dosimetria (IRD). The samples were analyzed using an inductively coupled plasma mass spectrometer (ICP-MS) at IRD. >From the knowledge of trace elements concentrations, could be evaluated the environmental quality parameters at the studied ecosystems. The data allowed evaluating some relevant aspects of the study of trace elements in soil and aquatic systems, with emphasis at the distribution, concentration and identification of main anthropic sources of contamination at environment. (author)