WorldWideScience

Sample records for detector coverage analysis

  1. Reduction of the unnecessary dose from the over-range area with a spiral dynamic z-collimator: comparison of beam pitch and detector coverage with 128-detector row CT.

    Science.gov (United States)

    Shirasaka, Takashi; Funama, Yoshinori; Hayashi, Mutsukazu; Awamoto, Shinichi; Kondo, Masatoshi; Nakamura, Yasuhiko; Hatakenaka, Masamitsu; Honda, Hiroshi

    2012-01-01

    Our purpose in this study was to assess the radiation dose reduction and the actual exposed scan length of over-range areas using a spiral dynamic z-collimator at different beam pitches and detector coverage. Using glass rod dosimeters, we measured the unilateral over-range scan dose between the beginning of the planned scan range and the beginning of the actual exposed scan range. Scanning was performed at detector coverage of 80.0 and 40.0 mm, with and without the spiral dynamic z-collimator. The dose-saving ratio was calculated as the ratio of the unnecessary over-range dose, with and without the spiral dynamic z-collimator. In 80.0 mm detector coverage without the spiral dynamic z-collimator, the actual exposed scan length for the over-range area was 108, 120, and 126 mm, corresponding to a beam pitch of 0.60, 0.80, and 0.99, respectively. With the spiral dynamic z-collimator, the actual exposed scan length for the over-range area was 48, 66, and 84 mm with a beam pitch of 0.60, 0.80, and 0.99, respectively. The dose-saving ratios with and without the spiral dynamic z-collimator for a beam pitch of 0.60, 0.80, and 0.99 were 35.07, 24.76, and 13.51%, respectively. With 40.0 mm detector coverage, the dose-saving ratios with and without the spiral dynamic z-collimator had the highest value of 27.23% with a low beam pitch of 0.60. The spiral dynamic z-collimator is important for a reduction in the unnecessary over-range dose and makes it possible to reduce the unnecessary dose by means of a lower beam pitch.

  2. Cherenkov detectors for spatial imaging applications using discrete-energy photons

    Energy Technology Data Exchange (ETDEWEB)

    Rose, Paul B.; Erickson, Anna S., E-mail: erickson@gatech.edu [Georgia Institute of Technology, Nuclear and Radiological Engineering, G.W. Woodruff School of Mechanical Engineering, 770 State St., Atlanta, Georgia 30332 (United States)

    2016-08-14

    Cherenkov detectors can offer a significant advantage in spatial imaging applications when excellent timing response, low noise and cross talk, large area coverage, and the ability to operate in magnetic fields are required. We show that an array of Cherenkov detectors with crude energy resolution coupled with monochromatic photons resulting from a low-energy nuclear reaction can be used to produce a sharp image of material while providing large and inexpensive detector coverage. The analysis of the detector response to relative transmission of photons with various energies allows for reconstruction of material's effective atomic number further aiding in high-Z material identification.

  3. Analysis on the Change of Grassland Coverage in the Source Region of Three Rivers during 2000-2012

    International Nuclear Information System (INIS)

    Luo, Chengfeng; Wang, Jiao; Liu, Meilin; Liu, Zhengjun

    2014-01-01

    The Source Region of Three Rivers (SRTR) has very important ecological functions which form an ecological security barrier for China's Qinghai-Tibet plateau. As the biggest nationally occuring nature reserve region in China, the ecological environment here is very fragile. In SRTR the grassland coverage is an effective detector to reflect the ecological environment condition, because it records the changing process of climatic and environmental sensitively. In recent years SRTR has been suffering pressures from both nature and social pressures. With MODIS data the study monitored the grassland coverage continuously in SRTR from 2000 to 2012. The density-model was adapted to estimate grassland coverage degree firstly. Then the degree of change and the change intensity, change type were used to judge the grassland coverage change trend comprehensively. For grassland coverage there was natural change annual or within the year, and the degree of change was used to judge if there was change or not. The grassland has another important characteristic, annual fluctuation, and it can be differed from sustained changes with change type. For grassland coverage, such continuous change, like improvement or degradation, and to what extent, has more guidance sense on specific production practice. On the base of change type and degree of change, change intensity was used to identify the change trend of the grassland coverage. The analysis results from our study show that steady state and fluctuation are two main change trends for the vegetation coverage in SRTR from 2000 to 2012. The conclusion of this paper can provide references in response to environment change research and in the regional ecological environmental protection project in SRTR

  4. Quad-Tree Visual-Calculus Analysis of Satellite Coverage

    Science.gov (United States)

    Lo, Martin W.; Hockney, George; Kwan, Bruce

    2003-01-01

    An improved method of analysis of coverage of areas of the Earth by a constellation of radio-communication or scientific-observation satellites has been developed. This method is intended to supplant an older method in which the global-coverage-analysis problem is solved from a ground-to-satellite perspective. The present method provides for rapid and efficient analysis. This method is derived from a satellite-to-ground perspective and involves a unique combination of two techniques for multiresolution representation of map features on the surface of a sphere.

  5. The need for consumer behavior analysis in health care coverage decisions.

    Science.gov (United States)

    Thompson, A M; Rao, C P

    1990-01-01

    Demographic analysis has been the primary form of analysis connected with health care coverage decisions. This paper reviews past demographic research and shows the need to use behavioral analyses for health care coverage policy decisions. A behavioral model based research study is presented and a case is made for integrated study into why consumers make health care coverage decisions.

  6. ALICE Photon Multiplicity Detector

    CERN Multimedia

    Nayak, T

    2013-01-01

    Photon Multiplicity Detector (PMD) measures the multiplicity and spatial distribution of photons in the forward region of ALICE on a event-by-event basis. PMD is a pre-shower detector having fine granularity and full azimuthal coverage in the pseudo-rapidity region 2.3 < η < 3.9.

  7. Semiconductor radiation detectors. Device physics

    International Nuclear Information System (INIS)

    Lutz, G.

    2007-01-01

    Starting from basic principles, the author, whose own contributions to these developments have been significant, describes the rapidly growing field of modern semiconductor detectors used for energy and position measurement radiation. This development was stimulated by requirements in elementary particle physics where it has led to important scientific discoveries. It has now spread to many other fields of science and technology. The book is written in a didactic way and includes an introduction to semiconductor physics. The working principles of semiconductor radiation detectors are explained in an intuitive way, followed by formal quantitative analysis. Broad coverage is also given to electronic signal readout and to the subject of radiation damage. The book is the first to comprehensively cover the semiconductor radiation detectors currently in use. It is useful as a teaching guide and as a reference work for research and applications. (orig.)

  8. Detector Simulation: Data Treatment and Analysis Methods

    CERN Document Server

    Apostolakis, J

    2011-01-01

    Detector Simulation in 'Data Treatment and Analysis Methods', part of 'Landolt-Börnstein - Group I Elementary Particles, Nuclei and Atoms: Numerical Data and Functional Relationships in Science and Technology, Volume 21B1: Detectors for Particles and Radiation. Part 1: Principles and Methods'. This document is part of Part 1 'Principles and Methods' of Subvolume B 'Detectors for Particles and Radiation' of Volume 21 'Elementary Particles' of Landolt-Börnstein - Group I 'Elementary Particles, Nuclei and Atoms'. It contains the Section '4.1 Detector Simulation' of Chapter '4 Data Treatment and Analysis Methods' with the content: 4.1 Detector Simulation 4.1.1 Overview of simulation 4.1.1.1 Uses of detector simulation 4.1.2 Stages and types of simulation 4.1.2.1 Tools for event generation and detector simulation 4.1.2.2 Level of simulation and computation time 4.1.2.3 Radiation effects and background studies 4.1.3 Components of detector simulation 4.1.3.1 Geometry modeling 4.1.3.2 External fields 4.1.3.3 Intro...

  9. BES detector

    International Nuclear Information System (INIS)

    Bai, J.Z.; Bian, Q.; Chen, G.M.; Chen, L.J.; Chen, S.N.; Chen, Y.Q.; Chen, Z.Q.; Chi, Y.K.; Cui, H.C.; Cui, X.Z.; Deng, S.S.; Deng, Y.W.; Ding, H.L.; Dong, B.Z.; Dong, X.S.; Du, X.; Du, Z.Z.; Feng, C.; Feng, Z.; Fu, Z.S.; Gao, C.S.; Gao, M.L.; Gao, S.Q.; Gao, W.X.; Gao, Y.N.; Gu, S.D.; Gu, W.X.; Guan, Y.Z.; Guo, H.F.; Guo, Y.N.; Guo, Y.Y.; Han, S.W.; Han, Y.; Hao, W.; He, J.; He, K.R.; He, M.J.; Hou, X.J.; Hu, G.Y.; Hu, J.S.; Hu, J.W.; Huang, D.Q.; Huang, Y.Z.; Jia, Q.P.; Jiang, C.H.; Ju, Q.; Lai, Y.F.; Lang, P.F.; Li, D.S.; Li, F.; Li, H.; Li Jia; Li, J.T.; Li Jin; Li, L.L.; Li, P.Q.; Li, Q.M.; Li, R.B.; Li, S.Q.; Li, W.; Li, W.G.; Li, Z.X.; Liang, G.N.; Lin, F.C.; Lin, S.Z.; Lin, W.; Liu, Q.; Liu, R.G.; Liu, W.; Liu, X.; Liu, Z.A.; Liu, Z.Y.; Lu, C.G.; Lu, W.D.; Lu, Z.Y.; Lu, J.G.; Ma, D.H.; Ma, E.C.; Ma, J.M.; Mao, H.S.; Mao, Z.P.; Meng, X.C.; Ni, H.L.; Nie, J.; Nie, Z.D.; Niu, W.P.; Pan, L.J.; Qi, N.D.; Qian, J.J.; Qu, Y.H.; Que, Y.K.; Rong, G.; Ruan, T.Z.; Shao, Y.Y.; Shen, B.W.; Shen, D.L.; Shen, J.; Sheng, H.Y.; Sheng, J.P.; Shi, H.Z.; Song, X.F.; Sun, H.S.; Tang, F.K.; Tang, S.Q.; Tian, W.H.; Wang, F.; Wang, G.Y.; Wang, J.G.; Wang, J.Y.; Wang, L.S.; Wang, L.Z.; Wang, M.; Wang, P.; Wang, P.L.; Wang, S.M.; Wang, S.Q.; Wang, T.J.; Wang, X.W.; Wang, Y.Y.; Wang, Z.H.; Wang, Z.J.; Wei, C.L.; Wei, Z.Z.; Wu, J.W.; Wu, S.H.; Wu, S.Q.; Wu, W.M.; Wu, X.D.; Wu, Z.D.; Xi, D.M.; Xia, X.M.; Xiao, J.; Xie, P.P.; Xie, X.X.; Xu, J.G.; Xu, R.S.; Xu, Z.Q.; Xuan, B.C.; Xue, S.T.; Yan, J.; Yan, S.P.; Yan, W.G.; Yang, C.Z.; Yang, C.M.; Yang, C.Y.; Yang, X.F.; Yang, X.R.; Ye, M.H.; Yu, C.H.; Yu, C.S.; Yu, Z.Q.; Zhang, B.Y.; Zhang, C.D.; Zhang, C.C.; Zhang, C.Y.; Zhang, D.H.; Zhang, G.; Zhang, H.Y.; Zhang, H.L.; Zhang, J.W.; Zhang, L.S.; Zhang, S.Q.; Zhang, Y.P.; Zhang, Y.; Zhang, Y.M.; Zhao, D.X.; Zhao, J.W.; Zhao, M.; Zhao, P.D.; Zhao, P.P.; Zhao, W.R.; Zhao, Z.G.; Zhao, Z.Q.; Zheng, J.P.; Zheng, L.S.; Zheng, M.; Zheng, W.S.; Zheng, Z.P.; Zhong, G.P.; Zhou, G.P.; Zhou, H.S.; Zhou, J.; Zhou Li; Zhou Lin; Zhou, M.; Zhou, Y.S.; Zhou, Y.H.; Zhu, G.S.; Zhu, Q.M.; Zhu, S.G.; Zhu, Y.C.; Zhu, Y.S.; Zhuang, B.A.

    1994-01-01

    The Beijing Spectrometer (BES) is a general purpose solenoidal detector at the Beijing Electron Positron Collider (BEPC). It is designed to study exclusive final states in e + e - annihilations at the center of mass energy from 3.0 to 5.6 GeV. This requires large solid angle coverage combined with good charged particle momentum resolution, good particle identification and high photon detection efficiency at low energies. In this paper we describe the construction and the performance of BES detector. (orig.)

  10. Agile deployment and code coverage testing metrics of the boot software on-board Solar Orbiter's Energetic Particle Detector

    Science.gov (United States)

    Parra, Pablo; da Silva, Antonio; Polo, Óscar R.; Sánchez, Sebastián

    2018-02-01

    In this day and age, successful embedded critical software needs agile and continuous development and testing procedures. This paper presents the overall testing and code coverage metrics obtained during the unit testing procedure carried out to verify the correctness of the boot software that will run in the Instrument Control Unit (ICU) of the Energetic Particle Detector (EPD) on-board Solar Orbiter. The ICU boot software is a critical part of the project so its verification should be addressed at an early development stage, so any test case missed in this process may affect the quality of the overall on-board software. According to the European Cooperation for Space Standardization ESA standards, testing this kind of critical software must cover 100% of the source code statement and decision paths. This leads to the complete testing of fault tolerance and recovery mechanisms that have to resolve every possible memory corruption or communication error brought about by the space environment. The introduced procedure enables fault injection from the beginning of the development process and enables to fulfill the exigent code coverage demands on the boot software.

  11. Pulse shape analysis and position determination in segmented HPGe detectors: The AGATA detector library

    Energy Technology Data Exchange (ETDEWEB)

    Bruyneel, B. [Universitaet zu Koeln, Institut fuer Kernphysik, Koeln (Germany); Service de Physique Nucleaire, CEA Saclay, Gif-sur-Yvette (France); Birkenbach, B.; Reiter, P. [Universitaet zu Koeln, Institut fuer Kernphysik, Koeln (Germany)

    2016-03-15

    The AGATA Detector Library (ADL) was developed for the calculation of signals from highly segmented large volume high-purity germanium (HPGe) detectors. ADL basis sets comprise a huge amount of calculated position-dependent detector pulse shapes. A basis set is needed for Pulse Shape Analysis (PSA). By means of PSA the interaction position of a γ -ray inside the active detector volume is determined. Theoretical concepts of the calculations are introduced and cover the relevant aspects of signal formation in HPGe. The approximations and the realization of the computer code with its input parameters are explained in detail. ADL is a versatile and modular computer code; new detectors can be implemented in this library. Measured position resolutions of the AGATA detectors based on ADL are discussed. (orig.)

  12. Detector placement optimization for cargo containers using deterministic adjoint transport examination for SNM detection

    International Nuclear Information System (INIS)

    McLaughlin, Trevor D.; Sjoden, Glenn E.; Manalo, Kevin L.

    2011-01-01

    With growing concerns over port security and the potential for illicit trafficking of SNM through portable cargo shipping containers, efforts are ongoing to reduce the threat via container monitoring. This paper focuses on answering an important question of how many detectors are necessary for adequate coverage of a cargo container considering the detection of neutrons and gamma rays. Deterministic adjoint transport calculations are performed with compressed helium- 3 polyethylene moderated neutron detectors and sodium activated cesium-iodide gamma-ray scintillation detectors on partial and full container models. Results indicate that the detector capability is dependent on source strength and potential shielding. Using a surrogate weapons grade plutonium leakage source, it was determined that for a 20 foot ISO container, five neutron detectors and three gamma detectors are necessary for adequate coverage. While a large CsI(Na) gamma detector has the potential to monitor the entire height of the container for SNM, the He-3 neutron detector is limited to roughly 1.25 m in depth. Detector blind spots are unavoidable inside the container volume unless additional measures are taken for adequate coverage. (author)

  13. Synchrotron radiation and multichannel detectors in structural analysis

    Energy Technology Data Exchange (ETDEWEB)

    Mokulskii, M

    1979-10-01

    A survey is presented of the development of multichannel synchrotron X radiation detectors for the structural analysis of crystals. Tests are currently under way of a 4-thousand-channel plane detector of soft X radiation. The detector consists of a multiwire proportional counter using argon and CO/sub 2/ as the working gases. The detector is coupled to a computer processing information and displaying the respective X-ray diffraction images on the monitor. The described equipment allows imaging, eg., the cross section of the elementary cell of a DNA crystal. A 16-thousand-channel detector exists in the present time and the building is envisaged of a detector with 65 thousand channels.

  14. Synchrotron radiation and multichannel detectors in structural analysis

    International Nuclear Information System (INIS)

    Mokulskij, M.

    1979-01-01

    A survey is presented of the development of multichannel synchrotron X radiation detectors for the structural analysis of crystals. Tests are currently under way of a 4-thousand-channel plane detector of soft X radiation. The detector consists of a multiwire proportional counter using argon and CO 2 as the working gases. The detector is coupled to a computer processing information and displaying the respective X-ray diffraction images on the monitor. The described equipment allows imaging, eg., the cross section of the elementary cell of a DNA crystal. A 16-thousand-channel detector exists in the present time and the building is envisaged of a detector with 65 thousand channels. (J.B.)

  15. Space Shuttle Communications Coverage Analysis for Thermal Tile Inspection

    Science.gov (United States)

    Kroll, Quin D.; Hwu, Shian U.; Upanavage, Matthew; Boster, John P.; Chavez, Mark A.

    2009-01-01

    The space shuttle ultra-high frequency Space-to-Space Communication System has to provide adequate communication coverage for astronauts who are performing thermal tile inspection and repair on the underside of the space shuttle orbiter (SSO). Careful planning and quantitative assessment are necessary to ensure successful system operations and mission safety in this work environment. This study assesses communication systems performance for astronauts who are working in the underside, non-line-of-sight shadow region on the space shuttle. All of the space shuttle and International Space Station (ISS) transmitting antennas are blocked by the SSO structure. To ensure communication coverage at planned inspection worksites, the signal strength and link margin between the SSO/ISS antennas and the extravehicular activity astronauts, whose line-of-sight is blocked by vehicle structure, was analyzed. Investigations were performed using rigorous computational electromagnetic modeling techniques. Signal strength was obtained by computing the reflected and diffracted fields along the signal propagation paths between transmitting and receiving antennas. Radio frequency (RF) coverage was determined for thermal tile inspection and repair missions using the results of this computation. Analysis results from this paper are important in formulating the limits on reliable communication range and RF coverage at planned underside inspection and repair worksites.

  16. Neutron detector development at Brookhaven

    International Nuclear Information System (INIS)

    Yu, B.; Harder, J.A.; Mead, J.A.; Radeka, V.; Schaknowski, N.A.; Smith, G.C.

    2003-01-01

    Two-dimensional thermal neutron detectors have been the subject of research and development at Brookhaven for over 20 years. Based primarily on multi-wire chambers filled with a gas mixture containing 3 He, these detectors have been used in wide-ranging studies of molecular biology and material science samples. At each phase of development, experimenters have sought improvements in key parameters such as position resolution, counting rate, efficiency, solid-angle coverage and stability. A suite of detectors has been developed with sensitive areas ranging from 5x5 to 50x50 cm 2 . These devices incorporate low-noise-position readout and the best position resolution for thermal neutron gas detectors. Recent developments include a 1.5 mx20 cm detector containing multiple segments with continuously sensitive readout, and detectors with unity gain for ultra-high rate capability and long-term stability

  17. Mark II magnetic detector for SPEAR

    International Nuclear Information System (INIS)

    Larsen, R.R.

    1975-01-01

    The Mark II Detector, presently in the design stage, is a SLAC/LBL detector project to replace the Mark I now in operation at SPEAR. While similar in concept to the Mark I it will have improved momentum resolution, shower detection, solid angle coverage for both triggering and tracking and a magnet design providing easier access to those particles transmitted through the aluminum coil

  18. ATLAS Pixel Detector Operational Experience

    CERN Document Server

    Di Girolamo, B; The ATLAS collaboration

    2011-01-01

    The ATLAS Pixel Detector is the innermost detector of the ATLAS experiment at the Large Hadron Collider at CERN, providing high-resolution measurements of charged particle tracks in the high radiation environment close to the collision region. This capability is vital for the identification and measurement of proper decay times of long-lived particles such as b-hadrons, and thus vital for the ATLAS physics program. The detector provides hermetic coverage with three cylindrical layers and three layers of forward and backward pixel detectors. It consists of approximately 80 million pixels that are individually read out via chips bump-bonded to 1744 n-in-n silicon substrates. In this talk, results from the successful operation of the Pixel Detector at the LHC will be presented, including monitoring, calibration procedures, timing optimization and detector performance. The detector performance is excellent: 96.9% of the pixels are operational, noise occupancy and hit efficiency exceed the design specification, an...

  19. Analysis and operation of DePFET X-ray imaging detectors

    International Nuclear Information System (INIS)

    Lauf, Thomas

    2011-01-01

    The latest active pixel sensor for X-ray imaging spectroscopy developed at the Max-Planck-Halbleiterlabor (HLL) is the Depleted P-channel Field Effect Transistor (DePFET). This detector type unites detector and first stage amplification and has excellent energy resolution, low noise readout at high speed and low power consumption. This is combined with the possibility of random accessibility of pixels and on-demand readout. In addition it possesses all advantages of a sidewards depleted device, i.e. 100% fill factor and very good quantum efficiency. In the course of the development of DePFET detectors the need of a data analysis software for DePFET devices became apparent. A new tool was developed within the scope of this thesis, which should enable scientists to analyze DePFET data, but also be flexible enough so it can be adapted to new device variants and analysis challenges. A modular concept was thus implemented: a base program running an analysis by individual steps encapsulating algorithms, which can be interchanged. The result is a flexible, adaptable, and expandable analysis software. The software was used to investigate and qualify different structural variants of DePFET detectors. Algorithms to examine detector effects and methods to correct them were developed and integrated into the software. This way, a standard analysis suite for DePFET data was built up which is used at the HLL. Beside the planned use as detector for the wide field imager in the space X-ray observatory IXO, DePFET matrices will be used as focal plane array on the Mercury Imaging X-ray Spectrometer on board the Mercury probe BepiColombo which is scheduled for launch in 2014. The developed analysis software was used in the detector development for this mission to qualify test structures, analyze detector effects and study experimental results. In the course of this development, detector prototypes were studied in respect of linearity, charge collection and detection efficiency in an

  20. Analysis and operation of DePFET X-ray imaging detectors

    Energy Technology Data Exchange (ETDEWEB)

    Lauf, Thomas

    2011-04-28

    The latest active pixel sensor for X-ray imaging spectroscopy developed at the Max-Planck-Halbleiterlabor (HLL) is the Depleted P-channel Field Effect Transistor (DePFET). This detector type unites detector and first stage amplification and has excellent energy resolution, low noise readout at high speed and low power consumption. This is combined with the possibility of random accessibility of pixels and on-demand readout. In addition it possesses all advantages of a sidewards depleted device, i.e. 100% fill factor and very good quantum efficiency. In the course of the development of DePFET detectors the need of a data analysis software for DePFET devices became apparent. A new tool was developed within the scope of this thesis, which should enable scientists to analyze DePFET data, but also be flexible enough so it can be adapted to new device variants and analysis challenges. A modular concept was thus implemented: a base program running an analysis by individual steps encapsulating algorithms, which can be interchanged. The result is a flexible, adaptable, and expandable analysis software. The software was used to investigate and qualify different structural variants of DePFET detectors. Algorithms to examine detector effects and methods to correct them were developed and integrated into the software. This way, a standard analysis suite for DePFET data was built up which is used at the HLL. Beside the planned use as detector for the wide field imager in the space X-ray observatory IXO, DePFET matrices will be used as focal plane array on the Mercury Imaging X-ray Spectrometer on board the Mercury probe BepiColombo which is scheduled for launch in 2014. The developed analysis software was used in the detector development for this mission to qualify test structures, analyze detector effects and study experimental results. In the course of this development, detector prototypes were studied in respect of linearity, charge collection and detection efficiency in an

  1. Fast simulation of the trigger system of the ATLAS detector at LHC

    International Nuclear Information System (INIS)

    Epp, B.; Ghete, V.M.; Kuhn, D.; Zhang, Y.J.

    2004-01-01

    The trigger system of the ATLAS detector aims to maximize the physics coverage and to be open to new and possibly unforeseen physics signatures. It is a multi-level system, composed from a hardware trigger at level-1, followed by the high-level-trigger (level-2 and event-filter). In order to understand its performance, to optimize it and to reduce its total cost, the trigger system requires a detailed simulation which is time- and resource-consuming. An alternative to the full detector simulation is a so-called 'fast simulation' which starts the analysis from particle level and replaces the full detector simulation and the detailed particle tracking with parametrized distributions obtained from the full simulation and/or a simplified detector geometry. The fast simulation offers a less precise description of trigger performance, but it is faster and less resource-consuming. (author)

  2. Analysis of Cameroon newspaper coverage of cross border conflicts

    African Journals Online (AJOL)

    Nexus of conflict reporting: Analysis of Cameroon newspaper coverage of cross ... The conflicts taking place in the Central African Republic, Chad, Nigeria and Gabon have raised ... Consequently, it is in the interest of the public .... of Humanitarian Affairs (OCHA, 2014), ... As what concerns the case of Nigeria, UNHCR.

  3. Proper joint analysis of summary association statistics requires the adjustment of heterogeneity in SNP coverage pattern.

    Science.gov (United States)

    Zhang, Han; Wheeler, William; Song, Lei; Yu, Kai

    2017-07-07

    As meta-analysis results published by consortia of genome-wide association studies (GWASs) become increasingly available, many association summary statistics-based multi-locus tests have been developed to jointly evaluate multiple single-nucleotide polymorphisms (SNPs) to reveal novel genetic architectures of various complex traits. The validity of these approaches relies on the accurate estimate of z-score correlations at considered SNPs, which in turn requires knowledge on the set of SNPs assessed by each study participating in the meta-analysis. However, this exact SNP coverage information is usually unavailable from the meta-analysis results published by GWAS consortia. In the absence of the coverage information, researchers typically estimate the z-score correlations by making oversimplified coverage assumptions. We show through real studies that such a practice can generate highly inflated type I errors, and we demonstrate the proper way to incorporate correct coverage information into multi-locus analyses. We advocate that consortia should make SNP coverage information available when posting their meta-analysis results, and that investigators who develop analytic tools for joint analyses based on summary data should pay attention to the variation in SNP coverage and adjust for it appropriately. Published by Oxford University Press 2017. This work is written by US Government employees and is in the public domain in the US.

  4. Coverage analysis of lists of genes involved in heterogeneous ...

    Indian Academy of Sciences (India)

    The rationale of our study was to specifically evaluate sequence coverage using ... Catherine Badens and Martin Krahn contributed equally to this work. the analysis of ... (Life Technologies) with sequencing data processing using the Torrent ... map4 parameter, which is the default option to balance rapid- ity and maintain a ...

  5. Pulse shape analysis optimization with segmented HPGe-detectors

    Energy Technology Data Exchange (ETDEWEB)

    Lewandowski, Lars; Birkenbach, Benedikt; Reiter, Peter [Institute for Nuclear Physics, University of Cologne (Germany); Bruyneel, Bart [CEA, Saclay (France); Collaboration: AGATA-Collaboration

    2014-07-01

    Measurements with the position sensitive, highly segmented AGATA HPGe detectors rely on the gamma-ray-tracking GRT technique which allows to determine the interaction point of the individual gamma-rays hitting the detector. GRT is based on a pulse shape analysis PSA of the preamplifier signals from the 36 segments and the central electrode of the detector. The achieved performance and position resolution of the AGATA detector is well within the specifications. However, an unexpected inhomogeneous distribution of interaction points inside the detector volume is observed as a result of the PSA even when the measurement is performed with an isotropically radiating gamma ray source. The clustering of interaction points motivated a study in order to optimize the PSA algorithm or its ingredients. Position resolution results were investigated by including contributions from differential crosstalk of the detector electronics, an improved preamplifier response function and a new time alignment. Moreover the spatial distribution is quantified by employing different χ{sup 2}-minimization procedures.

  6. A Novel Immune-Inspired Shellcode Detection Algorithm Based on Hyperellipsoid Detectors

    Directory of Open Access Journals (Sweden)

    Tianliang Lu

    2018-01-01

    Full Text Available Shellcodes are machine language codes injected into target programs in the form of network packets or malformed files. Shellcodes can trigger buffer overflow vulnerability and execute malicious instructions. Signature matching technology used by antivirus software or intrusion detection system has low detection rate for unknown or polymorphic shellcodes; to solve such problem, an immune-inspired shellcode detection algorithm was proposed, named ISDA. Static analysis and dynamic analysis were both applied. The shellcodes were disassembled to assembly instructions during static analysis and, for dynamic analysis, the API function sequences of shellcodes were obtained by simulation execution to get the behavioral features of polymorphic shellcodes. The extracted features of shellcodes were encoded to antigens based on n-gram model. Immature detectors become mature after immune tolerance based on negative selection algorithm. To improve nonself space coverage rate, the immune detectors were encoded to hyperellipsoids. To generate better antibody offspring, the detectors were optimized through clonal selection algorithm with genetic mutation. Finally, shellcode samples were collected and tested, and result shows that the proposed method has higher detection accuracy for both nonencoded and polymorphic shellcodes.

  7. A large area silicon UCN detector with the analysis of UCN polarization

    International Nuclear Information System (INIS)

    Lasakov, M.S.; Serebrov, A.P.; Khusainov, A.Kh.; Pustovoit, A.; Borisov, Yu.V.; Fomin, A.K.; Geltenbort, P.; Kon'kov, O.I.; Kotina, I.M.; Shablii, A.I.; Solovei, V.A.; Vasiliev, A.V.

    2005-01-01

    A silicon UCN detector with an area of 45cm 2 and with a 6 LiF converter was developed at PNPI. The spectral efficiency of the silicon UCN detector was measured by means of a gravitational spectrometer at ILL. The sandwich-type detector from two silicon plates with a 6 LiF converter placed between them was also studied. Using this type of technology the UCN detector with analysis of polarization was developed and tested. The analyzing power of this detector assembly reaches up to 75% for the main part of UCN spectrum. This UCN detector with analysis of UCN polarization can be used in the new EDM spectrometer

  8. Calibration Analysis Software for the ATLAS Pixel Detector

    CERN Document Server

    AUTHOR|(INSPIRE)INSPIRE-00372086; The ATLAS collaboration

    2016-01-01

    The calibration of the ATLAS Pixel detector at LHC fulfils two main purposes: to tune the front-end configuration parameters for establishing the best operational settings and to measure the tuning performance through a subset of scans. An analysis framework has been set up in order to take actions on the detector given the outcome of a calibration scan (e.g. to create a mask for disabling noisy pixels). The software framework to control all aspects of the Pixel detector scans and analyses is called Calibration Console. The introduction of a new layer, equipped with new Front End-I4 Chips, required an update the Console architecture. It now handles scans and scans analyses applied together to chips with different characteristics. An overview of the newly developed Calibration Analysis Software will be presented, together with some preliminary result.

  9. The 'stay-at-home' mother, postfeminism and neoliberalism: content analysis of UK news coverage

    OpenAIRE

    Shani Orgad; Sara De Benedictis

    2015-01-01

    This article analyzes the construction in the UK media of the ‘stay-at-home mother’, a maternal figure who received increasing visibility during the recession and its aftermath. Based on a content analysis of UK national newspaper coverage of stay-at-home mothers (2008–2013), this article argues that the stay-at-home mother emerges from its press coverage as a neoliberal postfeminist subject. On the one hand, the coverage complicates claims about antifeminist backlash and women’s harking back...

  10. Investigation of relative arrival time distributions of EAS electron and muon component with the KASCADE central detector

    International Nuclear Information System (INIS)

    Hafemann, W.; Haeusler, R.; Rebel, H.; Mathes, H.J.

    2000-01-01

    The central detector of the KASCADE experiment is equipped with two layers of scintillation detectors with different area coverage. The scintillators of both detector systems have a good timing resolution of about 1.6 ns. With these two arrangements we performed extensive measurements of the arrival time differences at different energy thresholds of the electron and the muon component of EAS. The observed time structure of the shower profile is classified according to different EAS parameters. We furthermore present an analysis and comparism based on detailed MC simulations of the shower development. This comparism shows good agreement between experimental data and the expected behaviour of the different time distributions. (orig.)

  11. Calorimetric energy-dispersive detectors for ion beam analysis

    International Nuclear Information System (INIS)

    Andersen, H.H.

    1985-01-01

    Energy-dispersive detectors for photons and alpha particles have recently been built. They are based on designs for infrared bolometric detectors working at liquid helium temperatures. For 5.5 Mev alpha particles the energy resolution (FWHM) has been published to be better than 35 keV in preliminary experiments, but thermodynamic limits to the resolution were calculated to be of the order of a few tens of eV. In the present paper limitations to the resolution caused by fluctuations in the processes converting particle energy to heat in the detectors will be calculated. It appears that an FWHM of a few hundred eV for MeV alphas may realistically be hoped for. As these detectors are windowless and may at the same time extend solid angles as large as surface-barrier detectors, be built in any desired geometrical shape, and work with count rates well above 10 3 Hz, exiting possibilities for ion beam analysis will open up through their realization. (orig.)

  12. CANDU safety analysis system establishment; development of trip coverage and multi-dimensional hydrogen analysis methodology

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Jong Ho; Ohn, M. Y.; Cho, C. H. [KOPEC, Taejon (Korea)

    2002-03-01

    The trip coverage analysis model requires the geometry network for primary and secondary circuit as well as the plant control system to simulate all the possible plant operating conditions throughout the plant life. The model was validated for the power maneuvering and the Wolsong 4 commissioning test. The trip coverage map was produced for the large break loss of coolant accident and the complete loss of class IV power event. The reliable multi-dimensional hydrogen analysis requires the high capability for thermal hydraulic modelling. To acquire such a basic capability and verify the applicability of GOTHIC code, the assessment of heat transfer model, hydrogen mixing and combustion model was performed. Also, the assessment methodology for flame acceleration and deflagration-to-detonation transition is established. 22 refs., 120 figs., 31 tabs. (Author)

  13. The forward ring imaging Cherenkov detector of DELPHI

    International Nuclear Information System (INIS)

    Adam, W.; Albrecht, E.; Ambec, I.; Augustinus, A.; Barnoux, C.; Bostjancic, B.; Botner, O.; Budziak, A.P.; Caloba, L.P.; Carecchio, P.; Cavalli, P.; Ceelie, L.; Cereseto, R.; Cerutti, G.; Dahl-Jensen, E.; Dam, P.; Damgaard, G.; Koning, N. de; De la Vega, A.S.; Dimitriou, N.; Dulinski, W.; Eek, L.O.; Ekeloef, T.; Erikson, J.; Florek, A.; Florek, B.; Fontanelli, F.; Fontenille, A.; Galuszka, K.; Garcia, J.; Gracco, V.; Hallgren, A.; Hao, W.; Henkes, T.; Isenhower, D.; Johansson, H.; Karvelas, E.; Kindblom, P.; Koene, B.; Korporaal, A.; Kostarakis, P.; Lenzen, G.; Lindqvist, L.E.; Lorenz, P.; Loukas, D.; Lund-Jensen, B.; Maltezos, A.; Markou, A.; Mattsson, L.; Medbo, J.; Michalowski, J.; Montano, F.; Nielsen, B.S.; Ostler, J.M.; Pakonski, K.; Perdikis, C.; Polok, G.; Robohm, A.; Sajot, G.; Sannino, M.; Saragas, E.; Schyns, E.; Squarcia, S.; Stavropoulos, G.; Stodulski, M.; Stopa, Z.; Thadome, J.; Theodosiou, G.E.; Traspedini, L.; Turala, M.; Ullaland, O.; Waerm, A.; Werner, J.; Xyroutsikos, S.; Zavrtanik, M.; Zevgolatakos, E.

    1994-01-01

    The Forward Ring Imaging Cherenkov detector of the DELPHI experiment at LEP provides hadron identification at polar angles 15 6 F 14 and a volume of gaseous C 4 F 10 , in combination provide coverage of momenta up to 40 GeV/c. A single array of photosensitive Time Projection Chambers registers the impact points of ultraviolet photons from both radiators. The design of the detector and of its readout system is described. First results obtained with a partly installed detector are reported. (orig.)

  14. The resistive plate WELL detector as a single stage thick gaseous multiplier detector

    Energy Technology Data Exchange (ETDEWEB)

    Bressler, Shikma; Breskin, Amos; Moleri, Luca; Kumar, Ashwini; Pitt, Michael [Department of Particle Physics and Astrophysics, Weizmann Institute of Science (WIS) (Israel); Kudella, Simon [Institut fuer Experimentelle Kernphysik (IEKP), KIT (Germany)

    2015-07-01

    Gaseous Electron Multiplier (GEM) detector use high electric fields inside the h ole of a foil to achieve a high charge multiplication. As a thicker version of G EMs based on printed circuit board (PCB) structures, Thick Gaseous Electron Multiplier (THGEM) detectors combine the high gain of a GEM foil with the robustness, stability and low production costs of a PCB and allow a large quantity of applications that require the coverage of a large area at low cost and moderate spatial resolution. One application the Weizmann Institute of Science (WIS) develops as a member of the RD51 framework is the Resistive Plate WELL (RPWELL) detector. This single stage detector allows a very stable, discharge free operation at high gain (10{sup 5}). The single stage operation allows a low total height and make s the RPWELL a candidate for the Digital Hadronic Calorimeter (DHCAL) of the International Large Detector (ILD) at the International Linear Collider (ILC). The talk gives an insight into the way the RPWELL works and shows results from the last test beam.

  15. A comparative analysis of coverage decisions for outpatient pharmaceuticals: evidence from Denmark, Norway and Sweden.

    Science.gov (United States)

    Grepstad, Mari; Kanavos, Panos

    2015-02-01

    This study analyses the reasons for differences and similarities in coverage recommendations for outpatient pharmaceuticals in Denmark, Norway and Sweden, following HTA appraisals. A comparative analysis of all outpatient drug appraisals carried out between January 2009 and December 2012, including an analysis of divergent coverage recommendations made by all three countries was performed. Agreement levels between HTA agencies were measured using kappa scores. Consultations with stakeholders in the three countries were carried out to complement the discussion on HTA processes and reimbursement outcomes. Nineteen outpatient drug-indication pairs appraised in each of the three countries were identified, of which 6 pairs (32%) had divergent coverage recommendations. An uneven distribution of coverage recommendations was observed, with the highest overlap in appraisals between Norway and Sweden (free-marginal kappa 0.89). Similarities were found in priority setting principles, mode of appraisal and reasoning for coverage recommendations. The study shows that health economic evaluation is less prominent or explicit in outpatient drug appraisals in Denmark than in Norway and Sweden, that all three countries could benefit from improved communication between appraisers and manufacturers, and that final coverage recommendations rely on factors other than safety, comparative efficacy or cost-effectiveness. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  16. The PANDA detector at FAIR

    International Nuclear Information System (INIS)

    Bersani, Andrea

    2012-01-01

    The PANDA detector will be installed at FAIR to enterprise a long-term, wide-spectrum physics program in the strong interaction framework. The detector will be installed at the HESR accumulation ring, which will provide an anti-proton beam of unprecedented luminosity and momentum definition. The beam will interact with an internal target. The detector has been designed to allow a 4π coverage around the interaction region. Due to the relatively high energy of the beam, up to 15 GeV, PANDA will feature two magnetic spectrometers: the target spectrometer (TS), with a superconducting solenoid and covering the interaction region, and a forward spectrometer (FS), with a normal-conducting dipole and covering the small angles region. Since the physics program is wide and the requirements on the various subsystems are different, the detector has been designed to be as flexible as possible. The complete detector will be described in detail, both from the viewpoint of the proposed techniques and from the viewpoint of the expected performances. An overview of the status of various components of the detector will be presented, too.

  17. The PANDA detector at FAIR

    Science.gov (United States)

    Bersani, Andrea

    2012-10-01

    The PANDA detector will be installed at FAIR to enterprise a long-term, wide-spectrum physics program in the strong interaction framework. The detector will be installed at the HESR accumulation ring, which will provide an anti-proton beam of unprecedented luminosity and momentum definition. The beam will interact with an internal target. The detector has been designed to allow a 4π coverage around the interaction region. Due to the relatively high energy of the beam, up to 15 GeV, PANDA will feature two magnetic spectrometers: the target spectrometer (TS), with a superconducting solenoid and covering the interaction region, and a forward spectrometer (FS), with a normal-conducting dipole and covering the small angles region. Since the physics program is wide and the requirements on the various subsystems are different, the detector has been designed to be as flexible as possible. The complete detector will be described in detail, both from the viewpoint of the proposed techniques and from the viewpoint of the expected performances. An overview of the status of various components of the detector will be presented, too.

  18. Analysis of the TMI-2 source range detector response

    International Nuclear Information System (INIS)

    Carew, J.F.; Diamond, D.J.; Eridon, J.M.

    1980-01-01

    In the first few hours following the TMI-2 accident large variations (factors of 10-100) in the source range (SR) detector response were observed. The purpose of this analysis was to quantify the various effects which could contribute to these large variations. The effects evaluated included the transmission of neutrons and photons from the core to detector and the reduction in the multiplication of the Am-Be startup sources, and subsequent reduction in SR detector response, due to core voiding. A one-dimensional ANISN slab model of the TMI-2 core, core externals, pressure vessel and containment has been constructed for calculation of the SR detector response and is presented

  19. Planning Coverage Campaigns for Mission Design and Analysis: CLASP for DESDynl

    Science.gov (United States)

    Knight, Russell L.; McLaren, David A.; Hu, Steven

    2013-01-01

    Mission design and analysis presents challenges in that almost all variables are in constant flux, yet the goal is to achieve an acceptable level of performance against a concept of operations, which might also be in flux. To increase responsiveness, automated planning tools are used that allow for the continual modification of spacecraft, ground system, staffing, and concept of operations, while returning metrics that are important to mission evaluation, such as area covered, peak memory usage, and peak data throughput. This approach was applied to the DESDynl mission design using the CLASP planning system, but since this adaptation, many techniques have changed under the hood for CLASP, and the DESDynl mission concept has undergone drastic changes. The software produces mission evaluation products, such as memory highwater marks, coverage percentages, given a mission design in the form of coverage targets, concept of operations, spacecraft parameters, and orbital parameters. It tries to overcome the lack of fidelity and timeliness of mission requirements coverage analysis during mission design. Previous techniques primarily use Excel in ad hoc fashion to approximate key factors in mission performance, often falling victim to overgeneralizations necessary in such an adaptation. The new program allows designers to faithfully represent their mission designs quickly, and get more accurate results just as quickly.

  20. Comparison of forward and central collider detectors for beauty physics

    International Nuclear Information System (INIS)

    Kennedy, C.J.; Harr, R.F.; Karchin, P.E.

    1993-01-01

    A comparison of geometry, tracking, and muon triggering indicates that a central detector has a higher efficiency than a forward detector of equal psuedo rapidity coverage at both Tevatron and SSC energies. The difference at the Tevatron is considerable, about a factor of four. At the SSC, however, the difference is about a factor of two, so other considerations such as vertexing, particle ID, or cost may make a large forward detector an attractive option

  1. Semiconductor detectors in current energy dispersive X-ray spectral analysis

    Energy Technology Data Exchange (ETDEWEB)

    Betin, J; Zhabin, E; Krampit, I; Smirnov, V

    1980-04-01

    A review is presented of the properties of semiconductor detectors and of the possibilities stemming therefrom of using the detectors in X-ray spectral analysis in industries, in logging, in ecology and environmental control, in medicine, etc.

  2. Operational experience of the ATLAS Pixel detector

    CERN Document Server

    Hirschbuehl, D; The ATLAS collaboration

    2011-01-01

    The ATLAS Pixel Detector is the innermost detector of the ATLAS experiment at the Large Hadron Collider at CERN, providing high-resolution measurements of charged particle tracks in the high radiation environment close to the collision region. This capability is vital for the identification and measurement of proper decay times of long-lived particles such as b-hadrons, and thus vital for the ATLAS physics program. The detector provides hermetic coverage with three cylindrical layers and three layers of forward and backward pixel detectors. It consists of approximately 80 million pixels that are individually read out via chips bump-bonded to 1744 n-in-n silicon substrates. In this talk, results from the successful operation of the Pixel Detector at the LHC will be presented, including monitoring, calibration procedures, timing optimization and detector performance. The detector performance is excellent: 97,5% of the pixels are operational, noise occupancy and hit efficiency exceed the design specification, an...

  3. Operational experience of the ATLAS Pixel Detector

    CERN Document Server

    Marcisovsky, M; The ATLAS collaboration

    2011-01-01

    The ATLAS Pixel Detector is the innermost detector of the ATLAS experiment at the Large Hadron Collider at CERN, providing high-resolution measurements of charged particle tracks in the high radiation environment close to the collision region. This capability is vital for the identification and measurement of proper decay times of long-lived particles such as b-hadrons, and thus vital for the ATLAS physics program. The detector provides hermetic coverage with three cylindrical layers and three layers of forward and backward pixel detectors. It consists of approximately 80 million pixels that are individually read out via chips bump-bonded to 1744 n-in-n silicon substrates. In this talk, results from the successful operation of the Pixel Detector at the LHC will be presented, including monitoring, calibration procedures, timing optimization and detector performance. The detector performance is excellent: 97,5% of the pixels are operational, noise occupancy and hit efficiency exceed the design specification, an...

  4. Coupling Analysis of Heat Island Effects, Vegetation Coverage and Urban Flood in Wuhan

    Science.gov (United States)

    Liu, Y.; Liu, Q.; Fan, W.; Wang, G.

    2018-04-01

    In this paper, satellite image, remote sensing technique and geographic information system technique are main technical bases. Spectral and other factors comprehensive analysis and visual interpretation are main methods. We use GF-1 and Landsat8 remote sensing satellite image of Wuhan as data source, and from which we extract vegetation distribution, urban heat island relative intensity distribution map and urban flood submergence range. Based on the extracted information, through spatial analysis and regression analysis, we find correlations among heat island effect, vegetation coverage and urban flood. The results show that there is a high degree of overlap between of urban heat island and urban flood. The area of urban heat island has buildings with little vegetation cover, which may be one of the reasons for the local heavy rainstorms. Furthermore, the urban heat island has a negative correlation with vegetation coverage, and the heat island effect can be alleviated by the vegetation to a certain extent. So it is easy to understand that the new industrial zones and commercial areas which under constructions distribute in the city, these land surfaces becoming bare or have low vegetation coverage, can form new heat islands easily.

  5. Semiconductor detectors in current energy dispersive X-ray spectral analysis

    International Nuclear Information System (INIS)

    Betin, J.; Zhabin, E.; Krampit, I.; Smirnov, V.

    1980-01-01

    A review is presented of the properties of semiconductor detectors and of the possibilities stemming therefrom of using the detectors in X-ray spectral analysis in industries, in logging, in ecology and environmental control, in medicine, etc. (M.S.)

  6. Preliminary uranium enrichment analysis results using cadmium zinc telluride detectors

    International Nuclear Information System (INIS)

    Lavietes, A.D.; McQuaid, J.H.; Paulus, T.J.

    1995-01-01

    Lawrence Livermore National Laboratory (LLNL) and EG ampersand G ORTEC have jointly developed a portable ambient-temperature detection system that can be used in a number of application scenarios. The detection system uses a planar cadmium zinc telluride (CZT) detector with custom-designed detector support electronics developed at LLNL and is based on the recently released MicroNOMAD multichannel analyzer (MCA) produced by ORTEC. Spectral analysis is performed using software developed at LLNL that was originally designed for use with high-purity germanium (HPGe) detector systems. In one application, the CZT detection system determines uranium enrichments ranging from less than 3% to over 75% to within accuracies of 20%. The analysis was performed using sample sizes of 200 g or larger and acquisition times of 30 min. The authors have demonstrated the capabilities of this system by analyzing the spectra gathered by the CZT detection system from uranium sources of several enrichments. These experiments demonstrate that current CZT detectors can, in some cases, approach performance criteria that were previously the exclusive domain of larger HPGe detector systems

  7. Robust hybrid pitch detector for pathologic voice analysis

    OpenAIRE

    Boyanov, B.; Hadjitodorov, S.; Teston, B.; Doskov, D.

    1997-01-01

    International audience; A hybrid speech period (To) detector characterizided by parallel analyses of three speech signals in temporal spectral and cepstral domains and preprocessing for periodic/aperiodic (unvoiced) separation (PAS) is proposed. The preprocessing is realized by analysis in these three domains and PAS by multi layer Perceptron neural network.Two phonations of the wowel "a" of 40 speakers and 62 patients were analyzed. For the proposed detector errors were significantly minimized.

  8. Network television news coverage of environmental risks

    International Nuclear Information System (INIS)

    Greenberg, M.R.; Sandman, P.M.; Sachsman, D.V.; Salomone, K.L.

    1989-01-01

    Despite the criticisms that surround television coverage of environmental risk, there have been relatively few attempts to measure what and whom television shows. Most research has focused analysis on a few weeks of coverage of major stories like the gas leak at Bhopal, the Three Mile Island nuclear accident, or the Mount St. Helen's eruption. To advance the research into television coverage of environmental risk, an analysis has been made of all environmental risk coverage by the network nightly news broadcasts for a period of more than two years. Researchers have analyzed all environmental risk coverage-564 stories in 26 months-presented on ABC, CBS, and NBC's evening news broadcasts from January 1984 through February 1986. The quantitative information from the 564 stories was balanced by a more qualitative analysis of the television coverage of two case studies-the dioxin contamination in Times Beach, Missouri, and the suspected methyl isocyanate emissions from the Union Carbide plant in Institute, West Virginia. Both qualitative and quantitative data contributed to the analysis of the role played by experts and environmental advocacy sources in coverage of environmental risk and to the suggestions for increasing that role

  9. Design and performance of the focusing DIRC detector

    Energy Technology Data Exchange (ETDEWEB)

    Dey, B. [University of California, Riverside, CA 92521 (United States); Borsato, M.; Arnaud, N. [Laboratoire de l' Accélérateur Linéaire, Centre Scientifique d' Orsay, F-91898 Orsay Cedex (France); Leith, D.W.G.S.; Nishimura, K. [SLAC National Accelerator Laboratory, Stanford, CA 94309 (United States); Roberts, D.A. [University of Maryland, College Park, MD 20742, USA. (United States); Ratcliff, B.N. [SLAC National Accelerator Laboratory, Stanford, CA 94309 (United States); Varner, G. [University of Hawaii, Honolulu, HI 96822, USA. (United States); Va' vra, J., E-mail: jjv@slac.stanford.edu [SLAC National Accelerator Laboratory, Stanford, CA 94309 (United States)

    2015-03-01

    We present the final results from a novel Cherenkov imaging detector called the Focusing DIRC (FDIRC). This detector was designed as a full-scale prototype of the particle identification system for the SuperB experiment [1], and comprises 1/12 of the SuperB barrel azimuthal coverage, with partial photodetector and electronics implementation. The prototype was tested in the SLAC Cosmic Ray Telescope which provided 3D tracking of cosmic muons with an angular resolution of ~1.5 mrad, a position resolution of 4–5 mm, a start time resolution of 70 ps, and muon tracks above ~2 GeV tagged using an iron range stack. The fused silica focusing photon camera was coupled to a full-size BaBar DIRC bar box and was read out, over part of the full coverage, by 12 Hamamatsu H8500 multi-anode photomultipliers (MaPMTs) providing 768 pixels. We used waveform digitizing electronics to read out the MaPMTs. We give a detailed description of our data analysis methods and point out limitations on the present performance. We present results that demonstrate some basic performance characteristics of this design, including (a) single photon Cherenkov angle resolutions with and without chromatic corrections, (b) signal-to-noise (S/N) ratio between the Cherenkov peak and background, which primarily consists of ambiguities of the possible photon paths from emission along the track to a given pixel, (c) dTOP=TOP{sub measured} – TOP{sub expected} resolutions (with TOP being the photon Time-of-Propagation in fused silica), and (d) performance of the detector in the presence of high-rate backgrounds.

  10. Operational experience with the ATLAS Pixel Detector

    CERN Document Server

    Ince, T; The ATLAS collaboration

    2012-01-01

    The ATLAS Pixel Detector is the innermost element of the ATLAS experiment at the Large Hadron Collider at CERN, providing high-resolution measurements of charged particle tracks in the high radiation environment close to the collision region. This capability is vital for the identification and measurement of proper decay times of long-lived particles such as b-hadrons, and thus vital for the ATLAS physics program. The detector provides hermetic coverage with three cylindrical layers and three layers of forward and backward pixel detectors. It consists of approximately 80 million pixels that are individually read out via chips bump-bonded to 1744 n-in-n silicon substrates. In this paper, results from the successful operation of the Pixel Detector at the LHC will be presented, including monitoring, calibration procedures, timing optimization and detector performance. The detector performance is excellent: 96.2% of the pixels are operational, noise occupancy and hit efficiency exceed the design specification, an...

  11. A CAD based geometry model for simulation and analysis of particle detector data

    Energy Technology Data Exchange (ETDEWEB)

    Milde, Michael; Losekamm, Martin; Poeschl, Thomas; Greenwald, Daniel; Paul, Stephan [Technische Universitaet Muenchen, 85748 Garching (Germany)

    2016-07-01

    The development of a new particle detector requires a good understanding of its setup. A detailed model of the detector's geometry is not only needed during construction, but also for simulation and data analysis. To arrive at a consistent description of the detector geometry a representation is needed that can be easily implemented in different software tools used during data analysis. We developed a geometry representation based on CAD files that can be easily used within the Geant4 simulation framework and analysis tools based on the ROOT framework. This talk presents the structure of the geometry model and show its implementation using the example of the event reconstruction developed for the Multi-purpose Active-target Particle Telescope (MAPT). The detector consists of scintillating plastic fibers and can be used as a tracking detector and calorimeter with omnidirectional acceptance. To optimize the angular resolution and the energy reconstruction of measured particles, a detailed detector model is needed at all stages of the reconstruction.

  12. Vertex detectors

    International Nuclear Information System (INIS)

    Lueth, V.

    1992-07-01

    The purpose of a vertex detector is to measure position and angles of charged particle tracks to sufficient precision so as to be able to separate tracks originating from decay vertices from those produced at the interaction vertex. Such measurements are interesting because they permit the detection of weakly decaying particles with lifetimes down to 10 -13 s, among them the τ lepton and charm and beauty hadrons. These two lectures are intended to introduce the reader to the different techniques for the detection of secondary vertices that have been developed over the past decades. The first lecture includes a brief introduction to the methods used to detect secondary vertices and to estimate particle lifetimes. It describes the traditional technologies, based on photographic recording in emulsions and on film of bubble chambers, and introduces fast electronic registration of signals derived from scintillating fibers, drift chambers and gaseous micro-strip chambers. The second lecture is devoted to solid state detectors. It begins with a brief introduction into semiconductor devices, and then describes the application of large arrays of strip and pixel diodes for charged particle tracking. These lectures can only serve as an introduction the topic of vertex detectors. Time and space do not allow for an in-depth coverage of many of the interesting aspects of vertex detector design and operation

  13. Search for the solar pp-neutrinos with an upgrade of CTF detector

    International Nuclear Information System (INIS)

    Smirnov, O.Yu.; Zajmidoroga, O.A.; Derbin, A.V.

    2001-01-01

    A possibility to use ultrapure liquid organic scintillator as a low energy solar neutrino detector is discussed. The detector with an active volume of 10 tons and 4π coverage will count 1.8 pp-neutrinos and 5.4 7 Be neutrinos per day with an energy threshold of 170 keV for the recoil electrons. The evaluation of the detector sensitivity and backgrounds is based on the results obtained by the Borexino collaboration with the Counting Test Facility (CTF). The detector can be build at the Italian Gran Sasso underground laboratory as an upgrade of the CTF detector using already developed technologies

  14. Numerical analysis of three-colour HgCdTe detectors

    Science.gov (United States)

    Jóźwikowski, K.; Rogalski, A.

    2007-12-01

    The performance of three-colour HgCdTe photovoltaic heterostructure detector is examined theoretically. In comparison with two-colour detectors with two back-to-back junctions, three-colour structure contains an absorber of intermediate wavelength placed between two junctions and electronic barriers are used to isolate this intermediate region. This structure was first proposed by British workers. Three-detector structures with different localizations of separating barriers are analyzed. The calculation results are presented in the form of spatial distributions of bandgap energy and quantum efficiency. Enhanced original computer programs are applied to solve the system of non-linear continuity equations for carriers and Poisson equations. In addition, the numerical analysis includes the dependence of absorption coefficient on Burstein effect as well as interference effects in heterostructure with metallic electrical contacts. It is shown that the performance of the detector is critically dependent on the barrier’s doping level and position in relation to the junction. This behaviour is serious disadvantage of the considered three-colour detector. A small shift of the barrier location and doping level causes serious changes in spectral responsivity.

  15. Gaseous detectors for energy dispersive X-ray fluorescence analysis

    Science.gov (United States)

    Veloso, J. F. C. A.; Silva, A. L. M.

    2018-01-01

    The energy resolution capability of gaseous detectors is being used in the last years to perform studies on the detection of characteristic X-ray lines emitted by elements when excited by external radiation sources. One of the most successful techniques is the Energy Dispersive X-ray Fluorescence (EDXRF) analysis. Recent developments in the new generation of micropatterned gaseous detectors (MPGDs), triggered the possibility not only of recording the photon energy, but also of providing position information, extending their application to EDXRF imaging. The relevant features and strategies to be applied in gaseous detectors in order to better fit the requirements for EDXRF imaging will be reviewed and discussed, and some application examples will be presented.

  16. HPGe detectors timing using pulse shape analysis techniques

    International Nuclear Information System (INIS)

    Crespi, F.C.L.; Vandone, V.; Brambilla, S.; Camera, F.; Million, B.; Riboldi, S.; Wieland, O.

    2010-01-01

    In this work the Pulse Shape Analysis has been used to improve the time resolution of High Purity Germanium (HPGe) detectors. A set of time aligned signals was acquired in a coincidence measurement using a coaxial HPGe and a cerium-doped lanthanum chloride (LaCl 3 :Ce) scintillation detector. The analysis using a Constant Fraction Discriminator (CFD) time output versus the HPGe signal shape shows that time resolution ranges from 2 to 12 ns depending on the slope in the initial part of the signal. An optimization procedure of the CFD parameters gives the same final time resolution (8 ns) as the one achieved after a correction of the CFD output based on the current pulse maximum position. Finally, an algorithm based on Pulse Shape Analysis was applied to the experimental data and a time resolution between 3 and 4 ns was obtained, corresponding to a 50% improvement as compared with that given by standard CFDs.

  17. An analysis of the policy coverage and examination of ...

    African Journals Online (AJOL)

    ... topics in subjects such as Life Sciences, Physical Sciences, Life Orientation, ... The aim of the research reported here was to investigate the coverage and ... In analysing the coverage and examination of environmental-impact topics, ...

  18. Operational Experience with the ATLAS Pixel Detector at LHC

    CERN Document Server

    Keil, M

    2013-01-01

    The ATLAS Pixel Detector is the innermost detector of the ATLAS experiment at the Large Hadron Collider at CERN, providing high-resolution measurements of charged particle tracks in the high radiation environment close to the collision region. This capability is vital for the identification and measurement of proper decay times of long-lived particles such as b-hadrons, and thus crucial for the ATLAS physics program. The detector provides hermetic coverage with three cylindrical layers and three layers of forward and backward pixel detectors. It consists of approximately 80 million pixels that are individually read out via front-end chips bump-bonded to 1744 n-on-n silicon substrates. In this paper results from the successful operation of the Pixel Detector at the LHC will be presented, including calibration procedures, detector performance and measurements of radiation damage. The detector performance is excellent: more than 95% of the pixels are operational, noise occupancy and hit efficiency exceed the des...

  19. The development of a single-crystal fiber-array scintillator area detector

    International Nuclear Information System (INIS)

    Loong, Chun; Vitt, Richard; Sayir, Ali; Sayir, Haluk

    2001-01-01

    The scientific output of a neutron instrument is directly proportional to the effectiveness of its detector system-coverage of scattering area, pixel resolution, counting efficiency, signal-to-noise ratio, life time and cost. The current neutron scintillator detectors employ mainly 6 Li-doped glass and ZnS, both of which present well-know limitations such as low light output, high gamma sensitivity in the case of 6 Li-glass and optical opacity in the case of ZnS. We aim to develop a position-sensitive, flight-time differentiable, efficient and cost-effective neutron detector system based on single-crystal scintillator fiber-arrays. The laser-heated melt modulation fiber growth technology developed at NASA provides the means to grow high-purity single-crystal fibers or rods of variable diameters (200 μm to 5 mm) and essentially unlimited length. Arrays of such fibers can be tailored to meet the requirements of pixel size, geometric configuration, and coverage area for a detector system. We report a plan in the growth and characterization of scintillators based on lithium silicates and boron aluminates using Ce as activator. (author)

  20. Determination of fuel assembly vibrational modes through analysis of incore detector noise

    International Nuclear Information System (INIS)

    Johnson, R.S.

    1986-01-01

    In order to better characterize fuel assembly vibration at Duke Power Company's Oconee Nuclear Station, incore noise data were acquired an analyzed from prompt responding detectors incorporated in the Oconee 2, Cycle 7 core. Duke Power Company began actively pursuing an inhouse Neutron Noise Analysis program for routine surveillance of reactor internals vibration in 1979. Noise data has since been acquired and analyzed for twelve cycles of operation for the three Oconee units. Duke Power's Oconee Unit 2 is a Babcock and Wilcoxs pressurized water reactor with a rate thermal power of 2568MW. For Oconee 2, Cycle 7 operation, two test assemblies, each employing a string of seven axially-spaced, prompt responding hafnium detectors, were included in the final core design. Incore detector noise data were obtained during Cycle 7 at approximately 281 and 430 effective full power days (EFPD). In addition to the incore test detector signals, noise signals from the upper and lower chambers of the four excore power range detectors were recorded to aid in the analysis. The comparison of RMS signal levels for each incore detector and the phase relationships between detector locations within two test assemblies identified the first four fuel assembly bending modes associated with fixed end conditions

  1. Comparative analysis of individuals with and without chiropractic coverage: patient characteristics, utilization, and costs.

    Science.gov (United States)

    Legorreta, Antonio P; Metz, R Douglas; Nelson, Craig F; Ray, Saurabh; Chernicoff, Helen Oster; Dinubile, Nicholas A

    2004-10-11

    Back pain accounts for more than $100 billion in annual US health care costs and is the second leading cause of physician visits and hospitalizations. This study ascertains the effect of systematic access to chiropractic care on the overall and neuromusculoskeletal-specific consumption of health care resources within a large managed-care system. A 4-year retrospective claims data analysis comparing more than 700 000 health plan members with an additional chiropractic coverage benefit and 1 million members of the same health plan without the chiropractic benefit. Members with chiropractic insurance coverage, compared with those without coverage, had lower annual total health care expenditures ($1463 vs $1671 per member per year, P<.001). Having chiropractic coverage was associated with a 1.6% decrease (P = .001) in total annual health care costs at the health plan level. Back pain patients with chiropractic coverage, compared with those without coverage, had lower utilization (per 1000 episodes) of plain radiographs (17.5 vs 22.7, P<.001), low back surgery (3.3 vs 4.8, P<.001), hospitalizations (9.3 vs 15.6, P<.001), and magnetic resonance imaging (43.2 vs 68.9, P<.001). Patients with chiropractic coverage, compared with those without coverage, also had lower average back pain episode-related costs ($289 vs $399, P<.001). Access to managed chiropractic care may reduce overall health care expenditures through several effects, including (1) positive risk selection; (2) substitution of chiropractic for traditional medical care, particularly for spine conditions; (3) more conservative, less invasive treatment profiles; and (4) lower health service costs associated with managed chiropractic care. Systematic access to managed chiropractic care not only may prove to be clinically beneficial but also may reduce overall health care costs.

  2. Cascaded systems analysis of photon counting detectors.

    Science.gov (United States)

    Xu, J; Zbijewski, W; Gang, G; Stayman, J W; Taguchi, K; Lundqvist, M; Fredenberg, E; Carrino, J A; Siewerdsen, J H

    2014-10-01

    Photon counting detectors (PCDs) are an emerging technology with applications in spectral and low-dose radiographic and tomographic imaging. This paper develops an analytical model of PCD imaging performance, including the system gain, modulation transfer function (MTF), noise-power spectrum (NPS), and detective quantum efficiency (DQE). A cascaded systems analysis model describing the propagation of quanta through the imaging chain was developed. The model was validated in comparison to the physical performance of a silicon-strip PCD implemented on an experimental imaging bench. The signal response, MTF, and NPS were measured and compared to theory as a function of exposure conditions (70 kVp, 1-7 mA), detector threshold, and readout mode (i.e., the option for coincidence detection). The model sheds new light on the dependence of spatial resolution, charge sharing, and additive noise effects on threshold selection and was used to investigate the factors governing PCD performance, including the fundamental advantages and limitations of PCDs in comparison to energy-integrating detectors (EIDs) in the linear regime for which pulse pileup can be ignored. The detector exhibited highly linear mean signal response across the system operating range and agreed well with theoretical prediction, as did the system MTF and NPS. The DQE analyzed as a function of kilovolt (peak), exposure, detector threshold, and readout mode revealed important considerations for system optimization. The model also demonstrated the important implications of false counts from both additive electronic noise and charge sharing and highlighted the system design and operational parameters that most affect detector performance in the presence of such factors: for example, increasing the detector threshold from 0 to 100 (arbitrary units of pulse height threshold roughly equivalent to 0.5 and 6 keV energy threshold, respectively), increased the f50 (spatial-frequency at which the MTF falls to a value of

  3. Automatic analysis of quality of images from X-ray digital flat detectors

    International Nuclear Information System (INIS)

    Le Meur, Y.

    2009-04-01

    Since last decade, medical imaging has grown up with the development of new digital imaging techniques. In the field of X-ray radiography, new detectors replace progressively older techniques, based on film or x-ray intensifiers. These digital detectors offer a higher sensibility and reduced overall dimensions. This work has been prepared with Trixell, the world leading company in flat detectors for medical radiography. It deals with quality control on digital images stemming from these detectors. High quality standards of medical imaging impose a close analysis of the defects that can appear on the images. This work describes a complete process for quality analysis of such images. A particular focus is given on the detection task of the defects, thanks to methods well adapted to our context of spatially correlated defects in noise background. (author)

  4. Regulation of antibiotic sales in Mexico: an analysis of printed media coverage and stakeholder participation.

    Science.gov (United States)

    Dreser, Anahí; Vázquez-Vélez, Edna; Treviño, Sandra; Wirtz, Veronika J

    2012-12-06

    Restricting antibiotics sales to those with medical prescriptions only is a central strategy for promoting appropriate use and containing antibiotic resistance; however, many low and middle income countries have not enforced policies that prevent widespread self-medication with antibiotics. In 2010, the Mexican government announced the enforcement of antibiotic sales regulations, a policy that gained media prominence. This study analyzes media coverage of issues, stakeholder representation, and positions taken during policy agenda setting, drafting, and implementation to shed light on policy making to promote appropriate antibiotic utilization. We carried out a quantitative content analysis of 322 newspaper articles published between January 2009 and December 2010 in 18 national and regional newspapers. Additionally, we conducted a qualitative content analysis to understand the positions adopted and strategies developed by nine key stakeholders. Framing theory guided the analysis. The Ministry of Health dominated media coverage, justifying the enforcement policy by focusing on risks of self-medication, and to a lesser degree dangers of increasing antibiotic resistance. Pharmacy associations appeared to be the leading opponents, arguing that the policy created logistical difficulties and corruption, and had negative economic impact for pharmacies and their clients. The associations developed strategies against the regulation such as attempting to delay implementation and installing physicians' consultation offices within pharmacies. While medical associations and academic institutions called for a comprehensive strategy to combat antibiotic resistance, improve prescription quality, and create public awareness, these issues had little impact on media coverage. Consumer groups and legislators received very little media coverage. The narrowly-focused and polarized media coverage ─centred on problems of self- medication and economic impact ─ was a missed opportunity

  5. Regulation of antibiotic sales in Mexico: an analysis of printed media coverage and stakeholder participation

    Directory of Open Access Journals (Sweden)

    Dreser Anahí

    2012-12-01

    Full Text Available Abstract Background Restricting antibiotics sales to those with medical prescriptions only is a central strategy for promoting appropriate use and containing antibiotic resistance; however, many low and middle income countries have not enforced policies that prevent widespread self-medication with antibiotics. In 2010, the Mexican government announced the enforcement of antibiotic sales regulations, a policy that gained media prominence. This study analyzes media coverage of issues, stakeholder representation, and positions taken during policy agenda setting, drafting, and implementation to shed light on policy making to promote appropriate antibiotic utilization. Methods We carried out a quantitative content analysis of 322 newspaper articles published between January 2009 and December 2010 in 18 national and regional newspapers. Additionally, we conducted a qualitative content analysis to understand the positions adopted and strategies developed by nine key stakeholders. Framing theory guided the analysis. Results The Ministry of Health dominated media coverage, justifying the enforcement policy by focusing on risks of self-medication, and to a lesser degree dangers of increasing antibiotic resistance. Pharmacy associations appeared to be the leading opponents, arguing that the policy created logistical difficulties and corruption, and had negative economic impact for pharmacies and their clients. The associations developed strategies against the regulation such as attempting to delay implementation and installing physicians’ consultation offices within pharmacies. While medical associations and academic institutions called for a comprehensive strategy to combat antibiotic resistance, improve prescription quality, and create public awareness, these issues had little impact on media coverage. Consumer groups and legislators received very little media coverage. Conclusions The narrowly-focused and polarized media coverage ─centred on

  6. Rapid Online Analysis of Local Feature Detectors and Their Complementarity

    Directory of Open Access Journals (Sweden)

    Shoaib Ehsan

    2013-08-01

    Full Text Available A vision system that can assess its own performance and take appropriate actions online to maximize its effectiveness would be a step towards achieving the long-cherished goal of imitating humans. This paper proposes a method for performing an online performance analysis of local feature detectors, the primary stage of many practical vision systems. It advocates the spatial distribution of local image features as a good performance indicator and presents a metric that can be calculated rapidly, concurs with human visual assessments and is complementary to existing offline measures such as repeatability. The metric is shown to provide a measure of complementarity for combinations of detectors, correctly reflecting the underlying principles of individual detectors. Qualitative results on well-established datasets for several state-of-the-art detectors are presented based on the proposed measure. Using a hypothesis testing approach and a newly-acquired, larger image database, statistically-significant performance differences are identified. Different detector pairs and triplets are examined quantitatively and the results provide a useful guideline for combining detectors in applications that require a reasonable spatial distribution of image features. A principled framework for combining feature detectors in these applications is also presented. Timing results reveal the potential of the metric for online applications.

  7. Scalable Background-Limited Polarization-Sensitive Detectors for mm-wave Applications

    Science.gov (United States)

    Rostem, Karwan; Ali, Aamir; Appel, John W.; Bennett, Charles L.; Chuss, David T.; Colazo, Felipe A.; Crowe, Erik; Denis, Kevin L.; Essinger-Hileman, Tom; Marriage, Tobias A.; hide

    2014-01-01

    We report on the status and development of polarization-sensitive detectors for millimeter-wave applications. The detectors are fabricated on single-crystal silicon, which functions as a low-loss dielectric substrate for the microwave circuitry as well as the supporting membrane for the Transition-Edge Sensor (TES) bolometers. The orthomode transducer (OMT) is realized as a symmetric structure and on-chip filters are employed to define the detection bandwidth. A hybridized integrated enclosure reduces the high-frequency THz mode set that can couple to the TES bolometers. An implementation of the detector architecture at Q-band achieves 90% efficiency in each polarization. The design is scalable in both frequency coverage, 30-300 GHz, and in number of detectors with uniform characteristics. Hence, the detectors are desirable for ground-based or space-borne instruments that require large arrays of efficient background-limited cryogenic detectors.

  8. New flux detectors for CANDU 6 reactors

    International Nuclear Information System (INIS)

    Cuttler, J.M.; Medak, N.

    1992-06-01

    CANDU reactors utilize large numbers of in-core self-powered detectors for control and protection. In the original design, the detectors (coaxial cables) were wound on carrier tubes and immersed in the heavy water moderator. Failures occurred due to corrosion and other factors, and replacement was very costly because the assemblies were not designed with maintenance in mind. A new design was conceived based on straight detectors, of larger diameter, in a sealed package of individual 'well' tubes. This protected the detectors from hostile environments and enabled individual failed sensors to be replaced by inserting spares in vacant neighbouring tubes. The new design was made retrofittable to older CANDU reactors. Provision was made for on-line scanning of the core with a miniature fission chamber. The modified detectors were tested in a lengthy development program and found to exhibit superior performance to that of the original detectors. Most of the CANDU reactors have now adopted the new design. In the case of the Gentilly-2 and Point Lepreau reactors, advantage was taken of the opportunity to redesign the detector layout (using better codes and the increased flexibility in positioning detectors) to achieve better coverage of abnormal events, leading to higher trip setpoints and wider operating margins

  9. Universal Health Insurance and the Reasons of not Coverage in Iran: Secondary Analysis of a National Household Survey

    Directory of Open Access Journals (Sweden)

    Shirin Nosratnejad

    2015-08-01

    Full Text Available Background and objectives : Universal insurance coverage is considered as one of the main goals of health systems around the world. Although Universal Health Insurance Law was legislated with the objective of covering all Iranian population under health insurance coverage in 1994, but imperfect insurance coverage has remained as a threatening dilemma. Heterogeneous statistics reported by insurer in Iran and the lack of appropriate, comprehensive databases have failed any judgments about the number of uninsured people and the reasons for it. Present study aimed to give better insight on insurance coverage among Iranian people and examine key reasons of imperfect coverage through a deep analysis of a national household survey. Material and Methods : Data which were collected from a national survey of health care utilization in Iran that covered over 102000 people of Iranians were analyzed. The survey had been implemented in 2007 by Iran's Ministry of Health. In order to identify possible reasons for imperfect coverage, national and international databases like SID, Iranmedex, ISC, Pubmed, Scopus, official statistics of Statistical Center of Iran (SCI, Iranian Social Security Organization (ISSO and Central Insurance of IRIRAN (CII were searched. Data management was accomplished in Microsoft Excel software.  Results : Study results showed that 85% of Iranian households had health insurance coverage, compared to 15% without any coverage. Medical services insurance fund had the greater proportion of coverage (59.27% and basic private insurance coverage was accountable for the least coverage (0.2%. More than half of households (51% stated financial inability to pay as the main reason for not getting coverage, followed by the lack of knowledge about insurance (12%, unemployment (12% and bypass by employers (10%. A worthwhile finding was that, 13% of households implied they felt no need to health insurance and 2% found it useless. Conclusion : Despite

  10. A bottom collider vertex detector design, Monte-Carlo simulation and analysis package

    International Nuclear Information System (INIS)

    Lebrun, P.

    1990-01-01

    A detailed simulation of the BCD vertex detector is underway. Specifications and global design issues are briefly reviewed. The BCD design based on double sided strip detector is described in more detail. The GEANT3-based Monte-Carlo program and the analysis package used to estimate detector performance are discussed in detail. The current status of the expected resolution and signal to noise ratio for the ''golden'' CP violating mode B d → π + π - is presented. These calculations have been done at FNAL energy (√s = 2.0 TeV). Emphasis is placed on design issues, analysis techniques and related software rather than physics potentials. 20 refs., 46 figs

  11. Global yellow fever vaccination coverage from 1970 to 2016: an adjusted retrospective analysis.

    Science.gov (United States)

    Shearer, Freya M; Moyes, Catherine L; Pigott, David M; Brady, Oliver J; Marinho, Fatima; Deshpande, Aniruddha; Longbottom, Joshua; Browne, Annie J; Kraemer, Moritz U G; O'Reilly, Kathleen M; Hombach, Joachim; Yactayo, Sergio; de Araújo, Valdelaine E M; da Nóbrega, Aglaêr A; Mosser, Jonathan F; Stanaway, Jeffrey D; Lim, Stephen S; Hay, Simon I; Golding, Nick; Reiner, Robert C

    2017-11-01

    Substantial outbreaks of yellow fever in Angola and Brazil in the past 2 years, combined with global shortages in vaccine stockpiles, highlight a pressing need to assess present control strategies. The aims of this study were to estimate global yellow fever vaccination coverage from 1970 through to 2016 at high spatial resolution and to calculate the number of individuals still requiring vaccination to reach population coverage thresholds for outbreak prevention. For this adjusted retrospective analysis, we compiled data from a range of sources (eg, WHO reports and health-service-provider registeries) reporting on yellow fever vaccination activities between May 1, 1939, and Oct 29, 2016. To account for uncertainty in how vaccine campaigns were targeted, we calculated three population coverage values to encompass alternative scenarios. We combined these data with demographic information and tracked vaccination coverage through time to estimate the proportion of the population who had ever received a yellow fever vaccine for each second level administrative division across countries at risk of yellow fever virus transmission from 1970 to 2016. Overall, substantial increases in vaccine coverage have occurred since 1970, but notable gaps still exist in contemporary coverage within yellow fever risk zones. We estimate that between 393·7 million and 472·9 million people still require vaccination in areas at risk of yellow fever virus transmission to achieve the 80% population coverage threshold recommended by WHO; this represents between 43% and 52% of the population within yellow fever risk zones, compared with between 66% and 76% of the population who would have required vaccination in 1970. Our results highlight important gaps in yellow fever vaccination coverage, can contribute to improved quantification of outbreak risk, and help to guide planning of future vaccination efforts and emergency stockpiling. The Rhodes Trust, Bill & Melinda Gates Foundation, the

  12. A gamma-ray tracking detector for molecular imaging

    International Nuclear Information System (INIS)

    Hall, C.J.; Lewis, R.A.; Helsby, W.I.; Nolan, P.; Boston, A.

    2003-01-01

    A design for a gamma-ray detector for molecular imaging is presented. The system is based on solid-state strip detector technology. The advantages of position sensitivity coupled with fine spectral resolution are exploited to produce a tracking detector for use with a variety of isotopes in nuclear medicine. Current design concepts employ both silicon and germanium layers to provide an energy range from 60 keV to >1 MeV. This allows a reference X-ray image to be collected simultaneously with the gamma-ray image providing accurate anatomical registration. The tracking ability of the gamma-ray detector allows ambiguities in the data set to be resolved which would otherwise cause events to be rejected in standard non-tracking system. Efficiency improvements that high solid angle coverage and the use of a higher proportion of events make time resolved imaging and multi-isotope work possible. A modular detector system, designed for viewing small animals has been accepted for funding

  13. Current applications of semiconductor x-ray detectors in chemical analysis

    International Nuclear Information System (INIS)

    Whitehead, N.E.

    1975-07-01

    In the last few years, semiconductor detectors have been used as X-ray detectors with great success, and the routine rapid accumulation of X-ray spectra is now possible. This review surveys the historical development of the detectors, the utilisation, and relative merits of various means of exciting the X-radiation from the elements in the sample, and compares the technique with other methods claiming to offer the capability of simultaneous multi-element analysis. It is concluded that it is of average sensitivity, but offers some advantages from its non-destructive nature, and in some cases its ability to offer information about the spatial distribution of elements in a sample. Other types of analysis may also be possible simultaneously. Sample preparation techniques are reviewed, especially techniques of manufacturing thin samples. An appendix contains details of the very wide variety of samples which have been analysed. More than 350 references are included. (auth.)

  14. Cascaded systems analysis of photon counting detectors

    International Nuclear Information System (INIS)

    Xu, J.; Zbijewski, W.; Gang, G.; Stayman, J. W.; Taguchi, K.; Carrino, J. A.; Lundqvist, M.; Fredenberg, E.; Siewerdsen, J. H.

    2014-01-01

    Purpose: Photon counting detectors (PCDs) are an emerging technology with applications in spectral and low-dose radiographic and tomographic imaging. This paper develops an analytical model of PCD imaging performance, including the system gain, modulation transfer function (MTF), noise-power spectrum (NPS), and detective quantum efficiency (DQE). Methods: A cascaded systems analysis model describing the propagation of quanta through the imaging chain was developed. The model was validated in comparison to the physical performance of a silicon-strip PCD implemented on an experimental imaging bench. The signal response, MTF, and NPS were measured and compared to theory as a function of exposure conditions (70 kVp, 1–7 mA), detector threshold, and readout mode (i.e., the option for coincidence detection). The model sheds new light on the dependence of spatial resolution, charge sharing, and additive noise effects on threshold selection and was used to investigate the factors governing PCD performance, including the fundamental advantages and limitations of PCDs in comparison to energy-integrating detectors (EIDs) in the linear regime for which pulse pileup can be ignored. Results: The detector exhibited highly linear mean signal response across the system operating range and agreed well with theoretical prediction, as did the system MTF and NPS. The DQE analyzed as a function of kilovolt (peak), exposure, detector threshold, and readout mode revealed important considerations for system optimization. The model also demonstrated the important implications of false counts from both additive electronic noise and charge sharing and highlighted the system design and operational parameters that most affect detector performance in the presence of such factors: for example, increasing the detector threshold from 0 to 100 (arbitrary units of pulse height threshold roughly equivalent to 0.5 and 6 keV energy threshold, respectively), increased the f 50 (spatial-frequency at

  15. Cascaded systems analysis of photon counting detectors

    Energy Technology Data Exchange (ETDEWEB)

    Xu, J.; Zbijewski, W.; Gang, G.; Stayman, J. W. [Department of Biomedical Engineering, Johns Hopkins University, Baltimore, Maryland 21205 (United States); Taguchi, K.; Carrino, J. A. [Russell H. Morgan Department of Radiology, Johns Hopkins University, Baltimore, Maryland 21205 (United States); Lundqvist, M.; Fredenberg, E. [Philips Healthcare, Solna 171 41 (Sweden); Siewerdsen, J. H., E-mail: jeff.siewerdsen@jhu.edu [Department of Biomedical Engineering, Johns Hopkins University, Baltimore, Maryland 21205 (United States); Russell H. Morgan Department of Radiology, Johns Hopkins University, Baltimore, Maryland 21205 (United States)

    2014-10-15

    Purpose: Photon counting detectors (PCDs) are an emerging technology with applications in spectral and low-dose radiographic and tomographic imaging. This paper develops an analytical model of PCD imaging performance, including the system gain, modulation transfer function (MTF), noise-power spectrum (NPS), and detective quantum efficiency (DQE). Methods: A cascaded systems analysis model describing the propagation of quanta through the imaging chain was developed. The model was validated in comparison to the physical performance of a silicon-strip PCD implemented on an experimental imaging bench. The signal response, MTF, and NPS were measured and compared to theory as a function of exposure conditions (70 kVp, 1–7 mA), detector threshold, and readout mode (i.e., the option for coincidence detection). The model sheds new light on the dependence of spatial resolution, charge sharing, and additive noise effects on threshold selection and was used to investigate the factors governing PCD performance, including the fundamental advantages and limitations of PCDs in comparison to energy-integrating detectors (EIDs) in the linear regime for which pulse pileup can be ignored. Results: The detector exhibited highly linear mean signal response across the system operating range and agreed well with theoretical prediction, as did the system MTF and NPS. The DQE analyzed as a function of kilovolt (peak), exposure, detector threshold, and readout mode revealed important considerations for system optimization. The model also demonstrated the important implications of false counts from both additive electronic noise and charge sharing and highlighted the system design and operational parameters that most affect detector performance in the presence of such factors: for example, increasing the detector threshold from 0 to 100 (arbitrary units of pulse height threshold roughly equivalent to 0.5 and 6 keV energy threshold, respectively), increased the f{sub 50} (spatial

  16. Operational Experience with the ATLAS Pixel Detector at the LHC

    CERN Document Server

    Keil, M; The ATLAS collaboration

    2012-01-01

    The ATLAS Pixel Detector is the innermost detector of the ATLAS experiment at the Large Hadron Collider at CERN, providing high-resolution measurements of charged particle tracks in the high radiation environment close to the collision region. This capability is vital for the identification and measurement of proper decay times of long-lived particles such as b-hadrons, and thus vital for the ATLAS physics program. The detector provides hermetic coverage with three cylindrical layers and three layers of forward and backward pixel detectors. It consists of approximately 80 million pixels that are individually read out via chips bump-bonded to 1744 n-in-n silicon substrates. In this talk, results from the successful operation of the Pixel Detector at the LHC and its status after three years of operation will be presented, including calibration procedures, timing optimization and detector performance. The detector performance is excellent: ~96 % of the pixels are operational, noise occupancy and hit efficiency e...

  17. Operational Experience with the ATLAS Pixel Detector at the LHC

    CERN Document Server

    Keil, M; The ATLAS collaboration

    2011-01-01

    The ATLAS Pixel Detector is the innermost detector of the ATLAS experiment at the Large Hadron Collider at CERN, providing high-resolution measurements of charged particle tracks in the high radiation environment close to the collision region. This capability is vital for the identification and measurement of proper decay times of long-lived particles such as b-hadrons, and thus vital for the ATLAS physics program. The detector provides hermetic coverage with three cylindrical layers and three layers of forward and backward pixel detectors. It consists of approximately 80 million pixels that are individually read out via chips bump-bonded to 1744 n-in-n silicon substrates. In this talk, results from the successful operation of the Pixel Detector at the LHC will be presented, including monitoring, calibration procedures, timing optimization and detector performance. The detector performance is excellent: 97,5% of the pixels are operational, noise occupancy and hit efficiency exceed the design specification, an...

  18. Operational experience with the ATLAS Pixel Detector at the LHC

    CERN Document Server

    Hirschbuehl, D; The ATLAS collaboration

    2011-01-01

    The ATLAS Pixel Detector is the innermost detector of the ATLAS experiment at the Large Hadron Collider at CERN, providing high-resolution measurements of charged particle tracks in the high radiation environment close to the collision region. This capability is vital for the identification and measurement of proper decay times of long-lived particles such as b-hadrons, and thus vital for the ATLAS physics program. The detector provides hermetic coverage with three cylindrical layers and three layers of forward and backward pixel detectors. It consists of approximately 80 million pixels that are individually read out via chips bump-bonded to 1744 n-in-n silicon substrates. In this paper results from the successful operation of the Pixel Detector at the LHC will be presented, including monitoring, calibration procedures, timing optimization and detector performance. The detector performance is excellent: 96.7% of the pixels are operational, noise occupancy and hit efficiency exceed the design specification, an...

  19. Operational experience with the ATLAS Pixel Detector at the LHC

    CERN Document Server

    Lapoire, C; The ATLAS collaboration

    2011-01-01

    The ATLAS Pixel Detector is the innermost detector of the ATLAS experiment at the Large Hadron Collider at CERN, providing high-resolution measurements of charged particle tracks in the high radiation environment close to the collision region. This capability is vital for the identification and measurement of proper decay times of long-lived particles such as b-hadrons, and thus vital for the ATLAS physics program. The detector provides hermetic coverage with three cylindrical layers and three layers of forward and backward pixel detectors. It consists of approximately 80 million pixels that are individually read out via chips bump-bonded to 1744 n-in-n silicon substrates. In this talk, results from the successful operation of the Pixel Detector at the LHC will be presented, including monitoring, calibration procedures, timing optimization and detector performance. The detector performance is excellent: 97,5% of the pixels are operational, noise occupancy and hit efficiency exceed the design specification, an...

  20. Operational Experience with the ATLAS Pixel Detector at the LHC

    CERN Document Server

    Lapoire, C; The ATLAS collaboration

    2012-01-01

    The ATLAS Pixel Detector is the innermost detector of the ATLAS experiment at the Large Hadron Collider at CERN, providing high-resolution measurements of charged particle tracks in the high radiation environment close to the collision region. This capability is vital for the identification and measurement of proper decay times of long-lived particles such as B-hadrons, and thus vital for the ATLAS physics program. The detector provides hermetic coverage with three cylindrical layers and three layers of forward and backward pixel detectors. It consists of approximately 80 million pixels that are individually read out via chips bump-bonded to 1744 n-in-n silicon substrates. In this paper, results from the successful operation of the Pixel Detector at the LHC will be presented, including monitoring, calibration procedures and detector performance. The detector performance is excellent: 96.2% of the pixels are operational, noise occupancy and hit efficiency exceed the design specification.

  1. Operational Experience with the ATLAS Pixel Detector at the LHC

    CERN Document Server

    Keil, M

    2012-01-01

    The ATLAS Pixel Detector is the innermost detector of the ATLAS experiment at the Large Hadron Collider at CERN, providing high-resolution measurements of charged particle tracks in the high radiation environment close to the collision region. This capability is vital for the identification and measurement of proper decay times of long-lived particles such as b-hadrons, and thus vital for the ATLAS physics program. The detector provides hermetic coverage with three cylindrical layers and three layers of forward and backward pixel detectors. It consists of approximately 80 million pixels that are individually read out via chips bump-bonded to 1744 n-in-n silicon substrates. In this paper results from the successful operation of the Pixel Detector at the LHC will be presented, including calibration procedures, timing optimization and detector performance. The detector performance is excellent: approximately 97% of the pixels are operational, noise occupancy and hit efficiency exceed the design specification, an...

  2. Operational experience with the ATLAS Pixel Detector at the LHC

    CERN Document Server

    Ince, T; The ATLAS collaboration

    2011-01-01

    The ATLAS Pixel Detector is the innermost detector of the ATLAS experiment at the Large Hadron Collider at CERN, providing high-resolution measurements of charged particle tracks in the high radiation environment close to the collision region. This capability is vital for the identification and measurement of proper decay times of long-lived particles such as b-hadrons, and thus vital for the ATLAS physics program. The detector provides hermetic coverage with three cylindrical layers and three layers of forward and backward pixel detectors. It consists of approximately 80 million pixels that are individually read out via chips bump-bonded to 1744 n-in-n silicon substrates. In this talk, results from the successful operation of the Pixel Detector at the LHC will be presented, including monitoring, calibration procedures, timing optimization and detector performance. The detector performance is excellent: 96.8% of the pixels are operational, noise occupancy and hit efficiency exceed the design specification, an...

  3. Operational experience with the ATLAS Pixel detector at the LHC

    CERN Document Server

    Deluca, C; The ATLAS collaboration

    2011-01-01

    The ATLAS Pixel Detector is the innermost detector of the ATLAS experiment at the Large Hadron Collider at CERN, providing high-resolution measurements of charged particle tracks in the high radiation environment close to the collision region. This capability is vital for the identification and measurement of proper decay times of long-lived particles such as b-hadrons, and thus vital for the ATLAS physics program. The detector provides hermetic coverage with three cylindrical layers and three layers of forward and backward pixel detectors. It consists of approximately 80 million pixels that are individually read out via chips bump-bonded to 1744 n-in-n silicon substrates. In this paper, results from the successful operation of the Pixel Detector at the LHC will be presented, including monitoring, calibration procedures, timing optimization and detector performance. The detector performance is excellent: 97,5\\% of the pixels are operational, noise occupancy and hit efficiency exceed the design specification, ...

  4. Operational Experience with the ATLAS Pixel Detector at the LHC

    CERN Document Server

    Lange, C; The ATLAS collaboration

    2011-01-01

    The ATLAS Pixel Detector is the innermost detector of the ATLAS experiment at the Large Hadron Collider at CERN, providing high-resolution measurements of charged particle tracks in the high radiation environment close to the collision region. This capability is vital for the identification and measurement of proper decay times of long-lived particles such as b-hadrons, and thus vital for the ATLAS physics program. The detector provides hermetic coverage with three cylindrical layers and three layers of forward and backward pixel detectors. It consists of approximately 80 million pixels that are individually read out via chips bump- bonded to 1744 n-in-n silicon substrates. In this talk, results from the successful operation of the Pixel Detector at the LHC will be presented, including monitoring, calibration procedures, timing optimization and detector performance. The detector performance is excellent: 97,5% of the pixels are operational, noise occupancy and hit efficiency exceed the design specification, a...

  5. Operational experience with the ATLAS Pixel detector at the LHC

    CERN Document Server

    Deluca, C; The ATLAS collaboration

    2011-01-01

    The ATLAS Pixel Detector is the innermost detector of the ATLAS experiment at the Large Hadron Collider at CERN, providing high-resolution measurements of charged particle tracks in the high radiation environment close to the collision region. This capability is vital for the identification and measurement of proper decay times of long-lived particles such as b-hadrons, and thus vital for the ATLAS physics program. The detector provides hermetic coverage with three cylindrical layers and three layers of forward and backward pixel detectors. It consists of approximately 80 million pixels that are individually read out via chips bump-bonded to 1744 n-in-n silicon substrates. In this talk, results from the successful operation of the Pixel Detector at the LHC will be presented, including monitoring, calibration procedures, timing optimization and detector performance. The detector performance is excellent: 97,5% of the pixels are operational, noise occupancy and hit efficiency exceed the design specification, an...

  6. Enhanced numerical analysis of three-color HgCdTe detectors

    Science.gov (United States)

    Jóźwikowski, K.; Rogalski, A.

    2007-04-01

    The performance of three-color HgCdTe photovoltaic heterostructure detector is examined theoretically. In comparison with two-color detectors with two back-to-back junctions, three-color structure contain an absorber of intermediate wavelength placed between two junctions, and electronic barriers are used to isolate this intermediate region. This structure was first proposed by British workers. Enhanced original computer programs are applied to solve the system of non-linear continuity equations for carriers and Poisson equations. In addition, the numerical analysis includes the dependence of absorption coefficient on Burstein effect as well as interference effects in heterostructure with metallic electrical contacts. Three detector structures with different localizations of separating barriers are analyzed. The calculations results are presented in the form of spatial distributions of bandgap energy and quantum efficiency. It is shown that the performance of the detector is critically dependent on the barrier's doping level and position in relation to the junction. This behavior is serious disadvantage of the considered three color detector. A small shift of the barrier location and doping level causes serious changes in spectral responsivity.

  7. Constraint likelihood analysis for a network of gravitational wave detectors

    International Nuclear Information System (INIS)

    Klimenko, S.; Rakhmanov, M.; Mitselmakher, G.; Mohanty, S.

    2005-01-01

    We propose a coherent method for detection and reconstruction of gravitational wave signals with a network of interferometric detectors. The method is derived by using the likelihood ratio functional for unknown signal waveforms. In the likelihood analysis, the global maximum of the likelihood ratio over the space of waveforms is used as the detection statistic. We identify a problem with this approach. In the case of an aligned pair of detectors, the detection statistic depends on the cross correlation between the detectors as expected, but this dependence disappears even for infinitesimally small misalignments. We solve the problem by applying constraints on the likelihood functional and obtain a new class of statistics. The resulting method can be applied to data from a network consisting of any number of detectors with arbitrary detector orientations. The method allows us reconstruction of the source coordinates and the waveforms of two polarization components of a gravitational wave. We study the performance of the method with numerical simulations and find the reconstruction of the source coordinates to be more accurate than in the standard likelihood method

  8. Characteristics of the ATLAS and CMS detectors

    CERN Document Server

    Seiden, Abraham

    2012-01-01

    The goal for the detection of new physics processes in particle collisions at Large Hadron Collider energies, combined with the broad spectrum of possibilities for how the physics might be manifest, leads to detectors of unprecedented scope and size for particle physics experiments at colliders. The resulting two detectors, ATLAS (A Toroidal LHC ApparatuS) and CMS (compact muon spectrometer), must search for the new physics processes within very complex events arising from the very high-energy collisions. The two experiments share many basic design features—in particular, the need for very selective triggering to weed out the bulk of the uninteresting events; the order in which detector types are arrayed in order to provide maximum information about each event; and the very large angular coverage required to constrain the energy carried by any non-interacting particles. However, within these basic constraints, the detectors are quite different given the different emphases placed on issues such as resolution...

  9. Improved candidate generation and coverage analysis methods for design optimization of symmetric multi-satellite constellations

    Science.gov (United States)

    Matossian, Mark G.

    1997-01-01

    Much attention in recent years has focused on commercial telecommunications ventures involving constellations of spacecraft in low and medium Earth orbit. These projects often require investments on the order of billions of dollars (US$) for development and operations, but surprisingly little work has been published on constellation design optimization for coverage analysis, traffic simulation and launch sequencing for constellation build-up strategies. This paper addresses the two most critical aspects of constellation orbital design — efficient constellation candidate generation and coverage analysis. Inefficiencies and flaws in the current standard algorithm for constellation modeling are identified, and a corrected and improved algorithm is presented. In the 1970's, John Walker and G. V. Mozhaev developed innovative strategies for continuous global coverage using symmetric non-geosynchronous constellations. (These are sometimes referred to as rosette, or Walker constellations. An example is pictured above.) In 1980, the late Arthur Ballard extended and generalized the work of Walker into a detailed algorithm for the NAVSTAR/GPS program, which deployed a 24 satellite symmetric constellation. Ballard's important contribution was published in his "Rosette Constellations of Earth Satellites."

  10. Measurement of Photomultipier Plateau Curves and Single MIP response in the AD detector at ALICE

    CERN Document Server

    Sanchez Falero, Sebastian De Jesus

    2015-01-01

    The Alice Diffractive (AD) detector is a forward detector in the ALICE experiment at CERN. It is aimed to the triggering on diffractive events and extends the pseudorapidity coverage to about 4.9 < /n/ < 6.3. In this work, a PMT's efficiency plateau and single MIP response are measured using a replica of the detector's scintillator modules, electronic and data acquisition system and cosmic rays as particle source.

  11. An annular ionization detector for quasi-elastic and transfer reaction studies

    CERN Document Server

    Dinesh, B V; Nayak, B K; Biswas, D C; Saxena, A; Pant, L M; Sahu, P K; Choudhury, R K

    2000-01-01

    An annular ionization chamber detector has been developed to study quasi-elastic and transfer reactions in heavy-ion collisions at near-barrier and sub-barrier energies. The important feature of the detector is that it has a near 2 pi coverage in the azimuthal angle phi for the particles entering in the detector at a given theta direction. This feature makes the detector very useful for measurement of the differential cross-sections at backward angles with respect to the beam direction, involving low cross-section reaction channels. The split anode configuration of the detector makes it capable of both particle identification and energy measurement for heavy ions and fission fragments. The detector has been tested using heavy-ion beams from the 14 MV-pelletron accelerator at Mumbai. Results on quasi-elastic excitation function measurements and barrier distribution studies in many heavy-ion reactions using this detector setup are discussed.

  12. Data analysis for solar neutrinos observed by water Cherenkov detectors{sup *}

    Energy Technology Data Exchange (ETDEWEB)

    Koshio, Yusuke [Okayama University, Okayama (Japan)

    2016-04-15

    A method of analyzing solar neutrino measurements using water-based Cherenkov detectors is presented. The basic detection principle is that the Cherenkov photons produced by charged particles via neutrino interaction are observed by photomultiplier tubes. A large amount of light or heavy water is used as a medium. The first detector to successfully measure solar neutrinos was Kamiokande in the 1980's. The next-generation detectors, i.e., Super-Kamiokande and the Sudbury Neutrino Observatory (SNO), commenced operation from the mid-1990's. These detectors have been playing the critical role of solving the solar neutrino problem and determining the neutrino oscillation parameters over the last decades. The future prospects of solar neutrino analysis using this technique are also described. (orig.)

  13. MTF measurement and analysis of linear array HgCdTe infrared detectors

    Science.gov (United States)

    Zhang, Tong; Lin, Chun; Chen, Honglei; Sun, Changhong; Lin, Jiamu; Wang, Xi

    2018-01-01

    The slanted-edge technique is the main method for measurement detectors MTF, however this method is commonly used on planar array detectors. In this paper the authors present a modified slanted-edge method to measure the MTF of linear array HgCdTe detectors. Crosstalk is one of the major factors that degrade the MTF value of such an infrared detector. This paper presents an ion implantation guard-ring structure which was designed to effectively absorb photo-carriers that may laterally defuse between adjacent pixels thereby suppressing crosstalk. Measurement and analysis of the MTF of the linear array detectors with and without a guard-ring were carried out. The experimental results indicated that the ion implantation guard-ring structure effectively suppresses crosstalk and increases MTF value.

  14. X-ray Peltier cooled detectors for X-ray fluorescence analysis

    International Nuclear Information System (INIS)

    Loupilov, A.; Sokolov, A.; Gostilo, V.

    2001-01-01

    The recent results on development of X-ray Si(Li), Si-planar and CdTe p-i-n detectors cooled by Peltier coolers for fabrication of laboratory and portable XRF analysers for different applications are discussed. Low detection limits of XRF analysers are provided by increasing of detectors sensitive surface; improvement of their spectrometrical characteristics; decreasing of front-end-electronics noise level; Peltier coolers and vacuum chambers cooling modes optimization. Solution of all mentioned tasks allowed to develop Peltier cooled detectors with the following performances: (1.) Si(Li) detectors: S=20 mm 2 , thickness=3.5 mm, 175 eV (5.9 keV), 430 eV (59.6 keV); S=100 mm 2 ; thickness=4.5 mm, 270 eV (5.9 keV), 485 eV (59.6 keV). (2.) Si-planar detector: S=10 mm 2 , thickness=0.4 mm, 230 eV (5.9 keV), 460 eV (59.6 keV). (3.) CdTe p-i-n detectors: S=16 mm 2 , thickness=0.5 mm, 350 eV (5.9 keV), 585 eV (59.6 keV). S=16 mm 2 , thickness=1.2 mm, 310 eV (5.9 keV), 600 eV (59.6 keV). Advantages and disadvantages of all types of detectors for X-ray fluorescence analysis are compared. Spectra are presented. Application of different XRF analysers based on developed detectors in medicine, environmental science, industry, cryminalistics and history of art are demonstrated

  15. X-ray Peltier cooled detectors for X-ray fluorescence analysis

    International Nuclear Information System (INIS)

    Loupilov, A.; Sokolov, A.; Gostilo, V.

    2000-01-01

    The recent results on development of X-ray Si(Li), Si-planar and CdTe p-i- n detectors cooled by Peltier coolers for fabrication of laboratory and portable XRF analysers for different applications are discussed. Low detection limits of XRF analysers are provided by increasing of detectors sensitive surface; improvement of their spectrometrical characteristics; decreasing of front-end-electronics noise level; Peltier coolers and vacuum chambers cooling modes optimization. Solution of all mentioned tasks allowed to develop Peltier cooled detectors with the following performances: (1) Si(Li) detectors: S = 20 mm 2 , thickness = 3.5 mm, 175 eV (5.9 keV), 430 eV (59.6 keV); S = 100 mm 2 ; thickness = 4.5 mm, 270 eV (5.9 keV), 485 eV (59,6 keV). (2) Si-planar detector: S = 10 mm 2 , thickness = 0.4 mm, 230 eV (5.9 keV), 460 eV (59.6 keV). (3) CdTe p-i-n detectors: S = 16 mm 2 , thickness 0.5 mm, 350 eV (5.9 keV), 585 eV (59.6 keV). S = 16 mm 2 , thickness = 1.2 mm, 310 eV (5.9 keV), 600 eV (59.6 keV). Advantages and disadvantages of all types of detectors for X-ray fluorescence analysis are compared. Spectra are presented. Application of different XRF analysers based on developed detectors in medicine, environmental science, industry, criminalistics and history of art are demonstrated. (author)

  16. Correction for hole trapping in AGATA detectors using pulse shape analysis

    Energy Technology Data Exchange (ETDEWEB)

    Bruyneel, B. [CEA Saclay, DSM/IRFU/SPhN, Gif-sur-Yvette Cedex (France); Universitaet zu Koeln, Institut fuer Kernphysik, Koeln (Germany); Birkenbach, B.; Eberth, J.; Hess, H.; Pascovici, Gh.; Reiter, P.; Wiens, A. [Universitaet zu Koeln, Institut fuer Kernphysik, Koeln (Germany); Bazzacco, D.; Farnea, E.; Michelagnoli, C.; Recchia, F. [INFN, Sezione di Padova, Padova (Italy); Collaboration: for the AGATA Collaboration

    2013-05-15

    Data from the highly segmented High-Purity Germanium (HPGe) detectors of the AGATA spectrometer show that segments are more sensitive to neutron damage than the central core contact. Calculations on the collection efficiency of charge carriers inside the HPGe detector were performed in order to understand this phenomenon. The trapping sensitivity, an expression based on the collection efficiencies for electrons and holes, is put forward to quantify the effect of charge carrier trapping. The sensitivity is evaluated for each position in the detector volume with respect to the different electrodes and the collected charge carrier type. Using the position information obtained by pulse shape analysis from the position-sensitive AGATA detectors, it is possible to correct for the energy deficit employing detector specific sensitivity values. We report on the successful correction of the energy peaks from heavily neutron-damaged AGATA detectors for core and segment electrode signals. The original energy resolution can optimally be recovered up to a certain quantifiable limit of degradation due to statistical fluctuations caused by trapping effects. (orig.)

  17. "Killed Out of Love": A Frame Analysis of Domestic Violence Coverage in Hong Kong.

    Science.gov (United States)

    Hernández, Miriam

    2017-11-01

    A frame analysis was conducted on a Hong Kong newspaper to determine whether news coverage of female fatalities at the hands of their intimate partners was reported in conventional domestic violence ways or if there were culture-specific explanations. Overall, most coverage supported known views of domestic violence, justifying the perpetrator and categorizing the issue as isolated crime. However, a few stories highlighted the historical subordination of women under patriarchy in Confucianism as an important cultural factor. Findings have implications for the lack of generalization of the social problem, and the understanding of cultural and political power in Hong Kong society.

  18. Special Nuclear Material Detection with a Water Cherenkov based Detector

    International Nuclear Information System (INIS)

    Sweany, M.; Bernstein, A.; Bowden, N.; Dazeley, S.; Svoboda, R.

    2008-01-01

    Fission events from Special Nuclear Material (SNM), such as highly enriched uranium or plutonium, produce a number of neutrons and high energy gamma-rays. Assuming the neutron multiplicity is approximately Poissonian with an average of 2 to 3, the observation of time correlations between these particles from a cargo container would constitute a robust signature of the presence of SNM inside. However, in order to be sensitive to the multiplicity, one would require a high total efficiency. There are two approaches to maximize the total efficiency; maximizing the detector efficiency or maximizing the detector solid angle coverage. The advanced detector group at LLNL is investigating one way to maximize the detector size. We are designing and building a water Cerenkov based gamma and neutron detector for the purpose of developing an efficient and cost effective way to deploy a large solid angle car wash style detector. We report on our progress in constructing a larger detector and also present preliminary results from our prototype detector that indicates detection of neutrons

  19. Defective pixel map creation based on wavelet analysis in digital radiography detectors

    International Nuclear Information System (INIS)

    Park, Chun Joo; Lee, Hyoung Koo; Song, William Y.; Achterkirchen, Thorsten Graeve; Kim, Ho Kyung

    2011-01-01

    The application of digital radiography detectors has attracted increasing attention in both medicine and industry. Since the imaging detectors are fabricated by semiconductor manufacturing process over large areas, defective pixels in the detectors are unavoidable. Moreover, the radiation damage due to the routine use of the detectors progressively increases the density of defective pixels. In this study, we present a method of identifying defective pixels in digital radiography detectors based on wavelet analysis. Artifacts generated due to wavelet transformations have been prevented by an additional local threshold method. The proposed method was applied to a sample digital radiography and the result was promising. The proposed method uses a single pair of dark and white images and does not require them to be corrected in gain-and-offset properties. This method will be helpful for the reliable use of digital radiography detectors through the working lifetime.

  20. Health workers and vaccination coverage in developing countries: an econometric analysis.

    Science.gov (United States)

    Anand, Sudhir; Bärnighausen, Till

    2007-04-14

    Vaccine-preventable diseases cause more than 1 million deaths among children in developing countries every year. Although health workers are needed to do vaccinations, the role of human resources for health as a determinant of vaccination coverage at the population level has not been investigated. Our aim was to test whether health worker density was positively associated with childhood vaccination coverage in developing countries. We did cross-country multiple regression analyses with coverage of three vaccinations--measles-containing vaccine (MCV); diphtheria, tetanus, and pertussis (DTP3); and poliomyelitis (polio3)--as dependent variables. Aggregate health worker density was an independent variable in one set of regressions; doctor and nurse densities were used separately in another set. We controlled for national income per person, female adult literacy, and land area. Health worker density was significantly associated with coverage of all three vaccinations (MCV p=0.0024; DTP3 p=0.0004; polio3 p=0.0008). However, when the effects of doctors and nurses were assessed separately, we found that nurse density was significantly associated with coverage of all three vaccinations (MCV p=0.0097; DTP3 p=0.0083; polio3 p=0.0089), but doctor density was not (MCV p=0.7953; DTP3 p=0.7971; polio3 p=0.7885). Female adult literacy was positively associated, and land area negatively associated, with vaccination coverage. National income per person had no effect on coverage. A higher density of health workers (nurses) increases the availability of vaccination services over time and space, making it more likely that children will be vaccinated. After controlling for other determinants, the level of income does not contribute to improved immunisation coverage. Health workers can be a major constraining factor on vaccination coverage in developing countries.

  1. Low-latency data analysis for the spherical detector Mario Schenberg

    International Nuclear Information System (INIS)

    Costa, Carlos Filipe Da Silva; Costa, César Augusto; Aguiar, Odylio Denys

    2014-01-01

    The confrontation of gravitational waves (GWs) with their electromagnetic (EM) counterparts will be rich with information about astrophysical events. Initially, this confrontation will corroborate GW detections; afterwards, when GW detections become more recurrent, it will allow astrophysics to combine information from different channels (GW, EM and also neutrinos). A low-latency data analysis which provides the direction of an incoming GW candidate is required to confront it with fast follow-up EM observations. Until now, no low-latency data analysis has been developed for spherical detectors. One spherical detector alone is capable of determining both the GW direction and polarization. By using this capability, we have developed a low-latency data analysis pipeline for the Mario Schenberg detector. This pipeline is able to retrieve the direction of GW triggers with an average angular resolution from δs ∼ 8° at SNR ∼ 12 to δs ∼ 1° at SNR ∼ 80, in a timespan of a 4 s for 32 s of data being analyzed. We apply a veto which reduces fake events up to 90% when maintaining the GW efficiency above 90% for high SNRs. We provide here a description of the method and its efficiency: resolution on the direction, false alarm rate and computational time. (paper)

  2. Implementing a Java Based GUI for RICH Detector Analysis

    Science.gov (United States)

    Lendacky, Andrew; Voloshin, Andrew; Benmokhtar, Fatiha

    2016-09-01

    The CLAS12 detector at Thomas Jefferson National Accelerator Facility (TJNAF) is undergoing an upgrade. One of the improvements is the addition of a Ring Imaging Cherenkov (RICH) detector to improve particle identification in the 3-8 GeV/c momentum range. Approximately 400 multi anode photomultiplier tubes (MAPMTs) are going to be used to detect Cherenkov Radiation in the single photoelectron spectra (SPS). The SPS of each pixel of all MAPMTs have been fitted to a mathematical model of roughly 45 parameters for 4 HVs, 3 OD. Out of those parameters, 9 can be used to evaluate the PMTs performance and placement in the detector. To help analyze data when the RICH is operational, a GUI application was written in Java using Swing and detector packages from TJNAF. To store and retrieve the data, a MySQL database program was written in Java using the JDBC package. Using the database, the GUI pulls the values and produces histograms and graphs for a selected PMT at a specific HV and OD. The GUI will allow researchers to easily view a PMT's performance and efficiency to help with data analysis and ring reconstruction when the RICH is finished.

  3. Analysis of Bracket Assembly for Portable Leak Detector Station

    International Nuclear Information System (INIS)

    ZIADA, H.H.

    1999-01-01

    This Supporting Document Presents Structural and Stress Analysis of a Portable Leak Detector Station for Tank Farms. The results show that the bracket assembly meets the requirements for dead load and natural phenomena hazards loads (seismic and wind)

  4. Silicon radiation detector analysis using back electron beam induced current

    International Nuclear Information System (INIS)

    Guye, R.

    1987-01-01

    A new technique for the observation and analysis of defects in silicon radiation detectors is described. This method uses an electron beam from a scanning electron microscope (SEM) impinging on the rear side of the p + n junction of the silicon detector, which itself is active and detects the electron beam induced current (EBIC). It is shown that this current is a sensitive probe of localized trapping centers, either at the junction surface or somewhere in the volume of the silicon crystal. (orig.)

  5. Superconducting nano-striplines as quantum detectors

    International Nuclear Information System (INIS)

    Casaburi, A.; Ejrnaes, M.; Mattioli, F.; Gaggero, A.; Leoni, R.; Martucciello, N.; Pagano, S.; Ohkubo, M.; Cristiano, R.

    2011-01-01

    The recent progress in the nanofabrication of superconducting films opens the road toward detectors with highly improved performances. This is the case for superconducting nano-striplines where the thickness and the width are pushed down to the extreme limits to realize detectors with unprecedented sensitivity and ultra fast response time. In this way quantum detectors for single photons at telecommunication wavelengths and for macromolecules such as proteins can be realized. As is often the case in applied nanotechnology, it is a challenge to make devices with the necessary macroscopic dimensions that are needed to interface present technologies, while maintaining the performance improvements. For nano-stripline detectors, both the fast temporal response and the device sensitivity is generally degraded when the area is increased. Here, we present how such detectors can be scaled up to macroscopic dimensions without losing the performance of the nano-structured active elements by using an innovative configuration. In order to realize ultrathin superconducting film the nano-layer is growth with a careful setup of the deposition technique which guarantees high quality and thickness uniformity at the nano-scale size. The active nano-strips are defined with the state-of-the-art electron beam nanolithography to achieve a highly uniform linewidth. We present working detectors based on nano-strips with thicknesses 9–40 nm and widths of 100–1000 nm which exhibit unprecedented speed and area coverage (40 × 40 μm 2 for single photon detectors and 1 × 1 mm 2 for single molecule detectors) based on niobium nitride thus enabling practical use of this nanotechnology.

  6. Status and future of the ATLAS Pixel Detector at the LHC

    International Nuclear Information System (INIS)

    Rozanov, Alexandre

    2013-01-01

    The ATLAS Pixel Detector is the innermost detector of the ATLAS experiment at the Large Hadron Collider at CERN. The detector provides hermetic coverage with three cylindrical layers and three layers of disks in each forward end-cap. It consists of approximately 80 million pixels that are individually read out via chips bump-bonded to 1744 n-on-n silicon substrates. Intensive calibration, tuning, timing optimization and monitoring resulted in the successful five years of operation with good detector performance. The record breaking instantaneous luminosities of 7.7×10 33 cm −2 s −1 recently surpassed at the LHC generated a rapidly increasing particle fluence in the ATLAS Pixel Detector. As the radiation dose accumulated, the first effects of radiation damage became observable in the silicon sensors as an increase in the silicon leakage current and the change of the voltage required to fully deplete the sensor. A fourth pixel layer at a radius of 3.3 cm will be added during the long shutdown (2013–2014) together with the replacement of pixel services. A letter of intent was submitted for a completely new Pixel Detector after 2023, capable to take data with extremely high leveled luminosities of 5×10 34 cm −2 s −1 at the high luminosity LHC. -- Highlights: •The ATLAS Pixel Detector provides hermetic coverage with three layers with 80 million pixels. •Calibration, tuning, timing optimization and monitoring resulted in the successful five years of operation with good detector performance. •First effects of radiation damage became observable in the silicon sensors. •A fourth pixel layer at a radius of 3.3 cm will be added during the long shutdown (2013–2014). •Replacement of pixel services in 2013–2014. •A letter of intent was submitted for new Pixel Detector after 2023 for high luminosity LHC

  7. A charged aerosol detector/chemiluminescent nitrogen detector/liquid chromatography/mass spectrometry system for regular and fragment compound analysis in drug discovery.

    Science.gov (United States)

    Jiang, Yutao; Hascall, Daniel; Li, Delia; Pease, Joseph H

    2015-09-11

    In this paper, we introduce a high throughput LCMS/UV/CAD/CLND system that improves upon previously reported systems by increasing both the quantitation accuracy and the range of compounds amenable to testing, in particular, low molecular weight "fragment" compounds. This system consists of a charged aerosol detector (CAD) and chemiluminescent nitrogen detector (CLND) added to a LCMS/UV system. Our results show that the addition of CAD and CLND to LCMS/UV is more reliable for concentration determination for a wider range of compounds than either detector alone. Our setup also allows for the parallel analysis of each sample by all four detectors and so does not significantly increase run time per sample. Copyright © 2015 Elsevier B.V. All rights reserved.

  8. Detector location selection based on VIP analysis in near-infrared detection of dural hematoma

    Directory of Open Access Journals (Sweden)

    Qiuming Sun

    2018-03-01

    Full Text Available Detection of dural hematoma based on multi-channel near-infrared differential absorbance has the advantages of rapid and non-invasive detection. The location and number of detectors around the light source are critical for reducing the pathological characteristics of the prediction model on dural hematoma degree. Therefore, rational selection of detector numbers and their distances from the light source is very important. In this paper, a detector position screening method based on Variable Importance in the Projection (VIP analysis is proposed. A preliminary modeling based on Partial Least Squares method (PLS for the prediction of dural position μa was established using light absorbance information from 30 detectors located 2.0–5.0 cm from the light source with a 0.1 cm interval. The mean relative error (MRE of the dural position μa prediction model was 4.08%. After VIP analysis, the number of detectors was reduced from 30 to 4 and the MRE of the dural position μa prediction was reduced from 4.08% to 2.06% after the reduction in detector numbers. The prediction model after VIP detector screening still showed good prediction of the epidural position μa. This study provided a new approach and important reference on the selection of detector location in near-infrared dural hematoma detection. Keywords: Detector location screening, Epidural hematoma detection, Variable importance in the projection

  9. R and D on a New Technology of Micro-pattern Gaseous Detectors Fast Timing Micro-pattern Detector

    CERN Document Server

    Salva Diblen, Sinem

    2016-01-01

    After the upgrades of the Large Hadron Collider (LHC) planned for the second and the third Long Shutdown (LS), the LHC luminosity will approach very high values. Such conditions will affect the performance of the CMS muon system, especially in the very forward region, due to the harsh expected background environment and high pile-up conditions. The CMS collaboration considers upgrading the muon forward region to take advantage of the pixel tracking coverage extension a new detector, ME0 station, possibly behind the new forward calorimeter. New resistive micro-pattern gaseous detectors that are able to handle the very demanding spatial, time resolution and rate capability, are being considered. In this contribution we introduce a new type of MPGD technology the Fast Timing Micro-pattern (FTM) detector, utilizing a fully resistive WELL structure. It consists of a stack of several coupled layers where drift and WELL multiplication stages alternate in the structure, yielding a significant improvement in timing p...

  10. The ADAQ framework: An integrated toolkit for data acquisition and analysis with real and simulated radiation detectors

    International Nuclear Information System (INIS)

    Hartwig, Zachary S.

    2016-01-01

    The ADAQ framework is a collection of software tools that is designed to streamline the acquisition and analysis of radiation detector data produced in modern digital data acquisition (DAQ) systems and in Monte Carlo detector simulations. The purpose of the framework is to maximize user scientific productivity by minimizing the effort and expertise required to fully utilize radiation detectors in a variety of scientific and engineering disciplines. By using a single set of tools to span the real and simulation domains, the framework eliminates redundancy and provides an integrated workflow for high-fidelity comparison between experimental and simulated detector performance. Built on the ROOT data analysis framework, the core of the ADAQ framework is a set of C++ and Python libraries that enable high-level control of digital DAQ systems and detector simulations with data stored into standardized binary ROOT files for further analysis. Two graphical user interface programs utilize the libraries to create powerful tools: ADAQAcquisition handles control and readout of real-world DAQ systems and ADAQAnalysis provides data analysis and visualization methods for experimental and simulated data. At present, the ADAQ framework supports digital DAQ hardware from CAEN S.p.A. and detector simulations performed in Geant4; however, the modular design will facilitate future extension to other manufacturers and simulation platforms. - Highlights: • A new software framework for radiation detector data acquisition and analysis. • Integrated acquisition and analysis of real-world and simulated detector data. • C++ and Python libraries for data acquisition hardware control and readout. • Graphical program for control and readout of digital data acquisition hardware. • Graphical program for comprehensive analysis of real-world and simulated data.

  11. The ADAQ framework: An integrated toolkit for data acquisition and analysis with real and simulated radiation detectors

    Energy Technology Data Exchange (ETDEWEB)

    Hartwig, Zachary S., E-mail: hartwig@mit.edu

    2016-04-11

    The ADAQ framework is a collection of software tools that is designed to streamline the acquisition and analysis of radiation detector data produced in modern digital data acquisition (DAQ) systems and in Monte Carlo detector simulations. The purpose of the framework is to maximize user scientific productivity by minimizing the effort and expertise required to fully utilize radiation detectors in a variety of scientific and engineering disciplines. By using a single set of tools to span the real and simulation domains, the framework eliminates redundancy and provides an integrated workflow for high-fidelity comparison between experimental and simulated detector performance. Built on the ROOT data analysis framework, the core of the ADAQ framework is a set of C++ and Python libraries that enable high-level control of digital DAQ systems and detector simulations with data stored into standardized binary ROOT files for further analysis. Two graphical user interface programs utilize the libraries to create powerful tools: ADAQAcquisition handles control and readout of real-world DAQ systems and ADAQAnalysis provides data analysis and visualization methods for experimental and simulated data. At present, the ADAQ framework supports digital DAQ hardware from CAEN S.p.A. and detector simulations performed in Geant4; however, the modular design will facilitate future extension to other manufacturers and simulation platforms. - Highlights: • A new software framework for radiation detector data acquisition and analysis. • Integrated acquisition and analysis of real-world and simulated detector data. • C++ and Python libraries for data acquisition hardware control and readout. • Graphical program for control and readout of digital data acquisition hardware. • Graphical program for comprehensive analysis of real-world and simulated data.

  12. Analysis of portable gamma flaw detectors concerning radiation hygiene

    International Nuclear Information System (INIS)

    Makarova, T.V.

    1982-01-01

    Design and shields of gamma flaw detectors as one of the main factors responsible for personnel dose were studied. The analysis was conducted using the results of radiation hygienic surveys of gamma flaw detection laboratories functioning constantly in Estonia. It is shown that recently the replacement of GUP apparatuses by flaw detectors of RID and ''Gamma-RID'' (types which have design and shielding advantages is observed. However personnel doses have not reduced considerably for the last 10 years. This fact is attributed to design disadvantages of the RID and ''Gamma-RID'' apparatuses the removing of which will give the decreasing of annual personnel dose by 80 %

  13. Statistical analysis of laser-interferometric detector Dylkin-1 data and data on seismic activity

    International Nuclear Information System (INIS)

    Kirillov, R S; Bochkarev, V V; Dulkyn, Academy of Sciences of the Republic of Tatarstan (Russian Federation))" data-affiliation=" (Scientific Center of Gravitational-Wave Research Dulkyn, Academy of Sciences of the Republic of Tatarstan (Russian Federation))" >Skochilov, A F

    2014-01-01

    This work presents statistical analysis of data collected from laser interferometric detector ''Dylkin-1'' and nearby seismic stations. The final goal of Dylkin project consists in creating detector of theoretically predicted gravitational waves produced by binary relativistic astrophysical objects. Currently, works are underway to improve sensitivity of detector by 2-3 orders. The goals of this research were to test isolation of detector from noise caused by seismic waves and to find out whether it is sensitive to variations in the gradient of gravitational potential (acceleration of free fall) caused by free Earth oscillations. Noise isolation has been tested by comparing energy of signals during significant seismic events. Sensitivity to variations in acceleration of free fall has been tested by means of cross-spectral analysis

  14. Coverage-based constraints for IMRT optimization

    Science.gov (United States)

    Mescher, H.; Ulrich, S.; Bangert, M.

    2017-09-01

    Radiation therapy treatment planning requires an incorporation of uncertainties in order to guarantee an adequate irradiation of the tumor volumes. In current clinical practice, uncertainties are accounted for implicitly with an expansion of the target volume according to generic margin recipes. Alternatively, it is possible to account for uncertainties by explicit minimization of objectives that describe worst-case treatment scenarios, the expectation value of the treatment or the coverage probability of the target volumes during treatment planning. In this note we show that approaches relying on objectives to induce a specific coverage of the clinical target volumes are inevitably sensitive to variation of the relative weighting of the objectives. To address this issue, we introduce coverage-based constraints for intensity-modulated radiation therapy (IMRT) treatment planning. Our implementation follows the concept of coverage-optimized planning that considers explicit error scenarios to calculate and optimize patient-specific probabilities q(\\hat{d}, \\hat{v}) of covering a specific target volume fraction \\hat{v} with a certain dose \\hat{d} . Using a constraint-based reformulation of coverage-based objectives we eliminate the trade-off between coverage and competing objectives during treatment planning. In-depth convergence tests including 324 treatment plan optimizations demonstrate the reliability of coverage-based constraints for varying levels of probability, dose and volume. General clinical applicability of coverage-based constraints is demonstrated for two cases. A sensitivity analysis regarding penalty variations within this planing study based on IMRT treatment planning using (1) coverage-based constraints, (2) coverage-based objectives, (3) probabilistic optimization, (4) robust optimization and (5) conventional margins illustrates the potential benefit of coverage-based constraints that do not require tedious adjustment of target volume objectives.

  15. Providing Universal Health Insurance Coverage in Nigeria.

    Science.gov (United States)

    Okebukola, Peter O; Brieger, William R

    2016-07-07

    Despite a stated goal of achieving universal coverage, the National Health Insurance Scheme of Nigeria had achieved only 4% coverage 12 years after it was launched. This study assessed the plans of the National Health Insurance Scheme to achieve universal health insurance coverage in Nigeria by 2015 and discusses the challenges facing the scheme in achieving insurance coverage. In-depth interviews from various levels of the health-care system in the country, including providers, were conducted. The results of the analysis suggest that challenges to extending coverage include the difficulty in convincing autonomous state governments to buy into the scheme and an inadequate health workforce that might not be able to meet increased demand. Recommendations for increasing the scheme's coverage include increasing decentralization and strengthening human resources for health in the service delivery systems. Strong political will is needed as a catalyst to achieving these goals. © The Author(s) 2016.

  16. Artificial neural networks application for analysis of gamma ray spectrum obtained from the scintillation detectors

    International Nuclear Information System (INIS)

    Stegowski, Z.

    2002-01-01

    Scintillation detectors are commonly used for the gamma ray detection. Actually the small peak resolution and the significant Compton effect fraction limit their utilization in the gamma ray spectrometry analysis. This article presents the artificial neural networks (ANN) application to the analysis of the gamma ray spectra acquired from scintillation detectors. The obtained results validate the effectiveness of the ANN method to spectrometry analysis. (author)

  17. Development of data acquisition and analysis software for multichannel detectors

    International Nuclear Information System (INIS)

    Chung, Y.

    1988-06-01

    This report describes the development of data acquisition and analysis software for Apple Macintosh computers, capable of controlling two multichannel detectors. With the help of outstanding graphics capabilities, easy-to-use user interface, and several other built-in convenience features, this application has enhanced the productivity and the efficiency of data analysis. 2 refs., 6 figs

  18. Pulse shape analysis for the gamma-ray tracking detector Agata

    International Nuclear Information System (INIS)

    Olariu, A.

    2007-10-01

    Agata is the European project for a 4π gamma-ray tracking array of 180 Ge detectors and is expected to have a detection sensitivity higher by 3 orders of magnitude than that of the present generation of gamma spectrometers. The trajectories of the photons inside a Ge crystal are reconstituted, which allows the determination of the initial energy of the incident photons as the total energy deposited along the track. The sequence of a γ-ray scattering process is too fast compared with the time resolution of the detector to be measured electronically, so tracking algorithms are necessary. Gamma-ray tracking detectors are operating in position sensitive mode it means that Ge crystal are segmented in order to facilitate the localization of the gamma interactions. It is possible to improve the position resolution by using the information conveyed by the shape of the detector signal. The task of the PSA (Pulse Shape Analysis) algorithm is to analyze this signal and extract the number of interactions, the position and the energy of each interaction. PSA algorithms rely on a basis of reference signals given by single interactions and that are obtained through an experimental characterization of the detector with scanning systems. The matrix method is a new PSA algorithm that consists in fitting linearly the detector signal with a set of calculated signals. We have tested this method with both simulated and measured signals. In the case of simulated single interactions the position resolution is 1.4 mm which is within Agata's specifications. For measured signals we have obtained mean positional errors of 3.2 mm at the front end of the detector an 4.8 mm at the back end

  19. a Performance Comparison of Feature Detectors for Planetary Rover Mapping and Localization

    Science.gov (United States)

    Wan, W.; Peng, M.; Xing, Y.; Wang, Y.; Liu, Z.; Di, K.; Teng, B.; Mao, X.; Zhao, Q.; Xin, X.; Jia, M.

    2017-07-01

    Feature detection and matching are key techniques in computer vision and robotics, and have been successfully implemented in many fields. So far there is no performance comparison of feature detectors and matching methods for planetary mapping and rover localization using rover stereo images. In this research, we present a comprehensive evaluation and comparison of six feature detectors, including Moravec, Förstner, Harris, FAST, SIFT and SURF, aiming for optimal implementation of feature-based matching in planetary surface environment. To facilitate quantitative analysis, a series of evaluation criteria, including distribution evenness of matched points, coverage of detected points, and feature matching accuracy, are developed in the research. In order to perform exhaustive evaluation, stereo images, simulated under different baseline, pitch angle, and interval of adjacent rover locations, are taken as experimental data source. The comparison results show that SIFT offers the best overall performance, especially it is less sensitive to changes of image taken at adjacent locations.

  20. A PERFORMANCE COMPARISON OF FEATURE DETECTORS FOR PLANETARY ROVER MAPPING AND LOCALIZATION

    Directory of Open Access Journals (Sweden)

    W. Wan

    2017-07-01

    Full Text Available Feature detection and matching are key techniques in computer vision and robotics, and have been successfully implemented in many fields. So far there is no performance comparison of feature detectors and matching methods for planetary mapping and rover localization using rover stereo images. In this research, we present a comprehensive evaluation and comparison of six feature detectors, including Moravec, Förstner, Harris, FAST, SIFT and SURF, aiming for optimal implementation of feature-based matching in planetary surface environment. To facilitate quantitative analysis, a series of evaluation criteria, including distribution evenness of matched points, coverage of detected points, and feature matching accuracy, are developed in the research. In order to perform exhaustive evaluation, stereo images, simulated under different baseline, pitch angle, and interval of adjacent rover locations, are taken as experimental data source. The comparison results show that SIFT offers the best overall performance, especially it is less sensitive to changes of image taken at adjacent locations.

  1. Media coverage of off-label promotion: a content analysis of US newspapers.

    Science.gov (United States)

    Joshi, Avani D; Patel, Dipen A; Holdford, David A

    2011-09-01

    Promotion of drugs for off-label use is newsworthy, because it is an illegal but all too common strategy used by pharmaceutical companies. The print media are an important source of information about coverage of off-label promotion of drugs and devices and can influence public perceptions of the practice. Print media coverage of off-label promotion during the years 1990-2008 were described and quantified. The primary themes and general tones relating to off-label promotion articles were evaluated. General concerns associated with off-label promotion and complaints about specific brand name drugs were also identified. Content analyses of the top 6 US newspapers were conducted over the period of 1990-2008 to analyze the media coverage given to off-label promotion of drugs and devices. Headlines and full text of articles were analyzed for primary themes and tones of the coverage. Intercoder reliability tests were performed on all the study variables. One hundred and one articles were identified meeting the study inclusion criteria. Coverage varied by newspaper. The Wall Street Journal had the most coverage on the topic (45%), and USA Today and Chicago Tribune had the least coverage (5%). Overall, most of the stories sampled were deemed to have a negative tone in coverage (77%), focusing mainly on lawsuits against drug companies for promoting their drugs for off-label uses. Pfizer's Neurontin(®) (Pfizer Inc., New York, NY 10017, USA) and Johnson & Johnson's Retin-A(®) (Orthoneutrogena, Los Angeles, CA 90045, USA) received the most media attention. The news media helps shape public understanding of promotional practices of pharmaceutical companies and their potential benefits and harms. This study suggests that print media coverage is generally negative about off-label promotion, focusing on legal actions taken against drug companies and the negative consequences of such promotional practices. Copyright © 2011 Elsevier Inc. All rights reserved.

  2. Performance of PILATUS detector technology for long-wavelength macromolecular crystallography

    International Nuclear Information System (INIS)

    Marchal, J.; Wagner, A.

    2011-01-01

    The long-wavelength MX beamline I23 currently under design at Diamond Light Source will be optimized in the X-ray energy range between 3 and 5 keV. At the moment no commercial off-the-shelf detector with high quantum efficiency and dynamic range is available to cover the large area required for diffraction experiments in this energy range. The hybrid pixel detector technology used in PILATUS detectors could overcome these limitations as the modular design could allow a large coverage in reciprocal space and high detection efficiency. Experiments were carried out on the Microfocus Spectroscopy beamline I18 at Diamond Light Source to test the performance of a 100K PILATUS module in the low-energy range from 2.3 to 3.7 keV.

  3. Resolution, coverage, and geometry beyond traditional limits

    Energy Technology Data Exchange (ETDEWEB)

    Ronen, Shuki; Ferber, Ralf

    1998-12-31

    The presentation relates to the optimization of the image of seismic data and improved resolution and coverage of acquired data. Non traditional processing methods such as inversion to zero offset (IZO) are used. To realize the potential of saving acquisition cost by reducing in-fill and to plan resolution improvement by processing, geometry QC methods such as DMO Dip Coverage Spectrum (DDCS) and Bull`s Eyes Analysis are used. The DDCS is a 2-D spectrum whose entries consist of the DMO (Dip Move Out) coverage for a particular reflector specified by it`s true time dip and reflector normal strike. The Bull`s Eyes Analysis relies on real time processing of synthetic data generated with the real geometry. 4 refs., 6 figs.

  4. Large area x-ray detectors for cargo radiography

    Science.gov (United States)

    Bueno, C.; Albagli, D.; Bendahan, J.; Castleberry, D.; Gordon, C.; Hopkins, F.; Ross, W.

    2007-04-01

    Large area x-ray detectors based on phosphors coupled to flat panel amorphous silicon diode technology offer significant advances for cargo radiologic imaging. Flat panel area detectors provide large object coverage offering high throughput inspections to meet the high flow rate of container commerce. These detectors provide excellent spatial resolution when needed, and enhanced SNR through low noise electronics. If the resolution is reduced through pixel binning, further advances in SNR are achievable. Extended exposure imaging and frame averaging enables improved x-ray penetration of ultra-thick objects, or "select-your-own" contrast sensitivity at a rate many times faster than LDAs. The areal coverage of flat panel technology provides inherent volumetric imaging with the appropriate scanning methods. Flat panel area detectors have flexible designs in terms of electronic control, scintillator selection, pixel pitch, and frame rates. Their cost is becoming more competitive as production ramps up for the healthcare, nondestructive testing (NDT), and homeland protection industries. Typically used medical and industrial polycrystalline phosphor materials such as Gd2O2S:Tb (GOS) can be applied to megavolt applications if the phosphor layer is sufficiently thick to enhance x-ray absorption, and if a metal radiator is used to augment the quantum detection efficiency and reduce x-ray scatter. Phosphor layers ranging from 0.2-mm to 1-mm can be "sandwiched" between amorphous silicon flat panel diode arrays and metal radiators. Metal plates consisting of W, Pb or Cu, with thicknesses ranging from 0.25-mm to well over 1-mm can be used by covering the entire area of the phosphor plate. In some combinations of high density metal and phosphor layers, the metal plate provides an intensification of 25% in signal due to electron emission from the plate and subsequent excitation within the phosphor material. This further improves the SNR of the system.

  5. Intra-aneurysmal flow disruption after implantation of the Medina® Embolization Device depends on aneurysm neck coverage.

    Science.gov (United States)

    Frölich, Andreas Maximilian; Nawka, Marie Teresa; Ernst, Marielle; Frischmuth, Isabell; Fiehler, Jens; Buhk, Jan-Hendrik

    2018-01-01

    Flow disruption achieved by braided intrasaccular implants is a novel treatment strategy for cerebrovascular aneurysms. We hypothesized that the degree of intra-aneurysmal flow disruption can be quantified in vitro and is influenced by device position across the aneurysm neck. We tested this hypothesis using the Medina® Embolization Device (MED). Ten different patient-specific elastic vascular models were manufactured. Models were connected to a pulsatile flow circuit, filled with a blood-mimicking fluid and treated by two operators using a single MED. Intra-aneurysmal flow velocity was measured using conventional and high-frequency digital subtraction angiography (HF-DSA) before and after each deployment. Aneurysm neck coverage by the implanted devices was assessed with flat detector computed tomography on a three-point Likert scale. A total of 80 individual MED deployments were performed by the two operators. The mean intra-aneurysmal flow velocity reduction after MED implantation was 33.6% (27.5-39.7%). No significant differences in neck coverage (p = 0.99) or flow disruption (p = 0.84) were observed between operators. The degree of flow disruption significantly correlated with neck coverage (ρ = 0.42, 95% CI: 0.21-0.59, p = 0.002) as well as with neck area (ρ = -0,35, 95% CI: -0.54 --0.13, p = 0.024). On multiple regression analysis, both neck coverage and total neck area were independent predictors of flow disruption. The degree of intra-aneurysmal flow disruption after MED implantation can be quantified in vitro and varies considerably between different aneurysms and different device configurations. Optimal device coverage across the aneurysm neck improves flow disruption and may thus contribute to aneurysm occlusion.

  6. Performance-Optimization Studies for the CLIC Vertex Detector

    CERN Document Server

    AUTHOR|(CDS)2085406; Roloff, Philipp

    The Compact Linear Collider (CLIC) is a mutli-TeV linear e+e- collider currently under development at CERN. In the post-LHC era, CLIC will allow to explore a great number of searches for New Physics such as the precise measurements of the Higgs boson. In this master thesis, we mainly focus on the development and the improvement of the vertex detector. The vertex detector requires excellent spatial resolution, low mass, geometrical coverage down to low polar angles, high rate readout for the sensors and new cooling technologies for heat removal. Considering such requirements, the CLIC vertex detector technology is far more advanced in comparison to the technologies currently used in particle physics. This project consists of two main parts. In the first part, we study the vertex detector and optimize its geometry for the use of airflow cooling techniques and also for flavor tagging. In the second part, we implement a decoder which can respect the timing constraints for the CLICpix chip, a silicon pixel detect...

  7. Insurance Coverage Policies for Personalized Medicine

    Directory of Open Access Journals (Sweden)

    Andrew Hresko

    2012-10-01

    Full Text Available Adoption of personalized medicine in practice has been slow, in part due to the lack of evidence of clinical benefit provided by these technologies. Coverage by insurers is a critical step in achieving widespread adoption of personalized medicine. Insurers consider a variety of factors when formulating medical coverage policies for personalized medicine, including the overall strength of evidence for a test, availability of clinical guidelines and health technology assessments by independent organizations. In this study, we reviewed coverage policies of the largest U.S. insurers for genomic (disease-related and pharmacogenetic (PGx tests to determine the extent that these tests were covered and the evidence basis for the coverage decisions. We identified 41 coverage policies for 49 unique testing: 22 tests for disease diagnosis, prognosis and risk and 27 PGx tests. Fifty percent (or less of the tests reviewed were covered by insurers. Lack of evidence of clinical utility appears to be a major factor in decisions of non-coverage. The inclusion of PGx information in drug package inserts appears to be a common theme of PGx tests that are covered. This analysis highlights the variability of coverage determinations and factors considered, suggesting that the adoption of personal medicine will affected by numerous factors, but will continue to be slowed due to lack of demonstrated clinical benefit.

  8. A study of the ability of the D0 detector to measure the single jet inclusive cross section

    International Nuclear Information System (INIS)

    Astur, R.V.

    1992-01-01

    The D0 experiment began accumulating data at the Fermilab Tevatron in May of 1992. Protons are collided with antiprotons at √s = 1.8 TeV and an expected peak luminosity of 5 x 10 30 cm -2 sec -1 . The D0 detector is an all-purpose detector that will have exceptional jet reconstruction capabilities derived from superior calorimetry and nearly 4π angular coverage. One of the many physics measurements that will be made at D0 is the inclusive jet cross section. Comparison of this cross section with theoretical predictions allows us to test the accuracy of the standard model of Quantum Chromodynamics (QCD). This comparison is usually in the form of a measurement of the differential cross section with respect to the transverse energy of the jet. The extended angular coverage of the D0 detector allows measurements of the differential cross section as a function of jet rapidity as well. Recently completed calculations of the next-to-leading-order contribution to the inclusive cross section result in predictions with reduced theoretical errors. In addition, recent fits to data from deep inelastic scattering and single photon experiments further restrict the quark and gluon structure functions of the proton which are necessary in the theoretical predictions of the cross section. It may be that an experimental measurement of the inclusive cross section would favor some of these fits over others. We have studied extensive computer simulations of both the Tevatron and the D0 detector in order to determine D0's ability to reconstruct the inclusive cross section. We present a discussion of this analysis as presently understood

  9. Detector system for in-situ spectrometric analysis of 241Am and Pu in soil

    International Nuclear Information System (INIS)

    Kirby, J.A.; Anspaugh, L.R.; Phelps, P.L.; Amantrout, G.A.; Sawyer, D.

    1975-01-01

    This system for quantitative analysis of Pu in soil via 241 Am has four 2.5-mm high-purity Ge detectors of 33 cm 2 total detecting surface area. These detectors are paralleled by gating circuitry to avoid the degradation of energy resolution associated with electronic output summing. In field tests the system was approximately three times as sensitive as a 70-cm 3 Ge(Li) detector and approximately an order of magnitude more sensitive than the FIDLER system

  10. Neutronic analysis of the Three Mile Island Unit 2 ex-core detector response

    International Nuclear Information System (INIS)

    Malloy, D.J.; Chang, Y.I.

    1981-10-01

    A neutronic analysis has been made with respect to the ex-core neutron detector response during the TMI-2 incident. A series of transport theory calculations quantified the impact upon the detector count rate of various core and downcomer conditions. In particular, various combinations of coolant void content and spatial distributions were investigated to yield the resulting transmission of the photoneutron source to the detector. The impact of a hypothetical distributed source within the downcomer region was also examined in order to simulate the potential effect of the release of neutron producing fission products into the coolant. These results are then offered as potential explanations for the anomalous behavior of the detector during the period of approx. 20 minutes through approx. 3 hours following the reactor scram

  11. Variability of surface ozone with cloud coverage over Kolkata, India

    Indian Academy of Sciences (India)

    Critical analysis of experimental surface ozone data and cloud coverage is reported over Kolkata during the period January 2011 to December 2011. Significant relationship between these two parameters is observed. Analysis shows that the trend of surface ozone concentration and cloud coverage follow opposite ...

  12. Spatial-temporal Evolution of Vegetation Coverage and Analysis of it’s Future Trends in Wujiang River Basin

    Science.gov (United States)

    Xiao, Jianyong; Bai, Xiaoyong; Zhou, Dequan; Qian, Qinghuan; Zeng, Cheng; Chen, Fei

    2018-01-01

    Vegetation coverage dynamics is affected by climatic, topography and human activities, which is an important indicator reflecting the regional ecological environment. Revealing the spatial-temporal characteristics of vegetation coverage is of great significance to the protection and management of ecological environment. Based on MODIS NDVI data and the Maximum Value Composites (MVC), we excluded soil spectrum interference to calculate Fractional Vegetation Coverage (FVC). Then the long-term FVC was used to calculate the spatial pattern and temporal variation of vegetation in Wujiang River Basin from 2000 to 2016 by using Trend analysis and Hurst index. The relationship between topography and spatial distribution of FVC was analyzed. The main conclusions are as follows: (1) The multi-annual mean vegetation coverage reveals a spatial distribution variation characteristic of low value in midstream and high level in other parts of the basin, owing a mean value of 0.6567. (2) From 2000 to 2016, the FVC of the Wujiang River Basin fluctuated between 0.6110 and 0.7380, and the overall growth rate of FVC was 0.0074/a. (3) The area of vegetation coverage tending to improve is more than that going to degrade in the future. Grass land, Arable land and Others improved significantly; karst rocky desertification comprehensive management project lead to persistent vegetation coverage improvement of Grass land, Arable land and Others. Residential land is covered with obviously degraded vegetation, resulting of urban sprawl; (4) The spatial distribution of FVC is positively correlated with TNI. Researches of spatial-temporal evolution of vegetation coverage have significant meaning for the ecological environment protection and management of the Wujiang River Basin.

  13. An integrated 3D design, modeling and analysis resource for SSC detector systems

    International Nuclear Information System (INIS)

    DiGiacomo, N.J.; Adams, T.; Anderson, M.K.; Davis, M.; Easom, B.; Gliozzi, J.; Hale, W.M.; Hupp, J.; Killian, K.; Krohn, M.; Leitch, R.; Lajczok, M.; Mason, L.; Mitchell, J.; Pohlen, J.; Wright, T.

    1989-01-01

    Integrated computer aided engineering and design (CAE/CAD) is having a significant impact on the way design, modeling and analysis is performed, from system concept exploration and definition through final design and integration. Experience with integrated CAE/CAD in high technology projects of scale and scope similar to SSC detectors leads them to propose an integrated computer-based design, modeling and analysis resource aimed specifically at SSC detector system development. The resource architecture emphasizes value-added contact with data and efficient design, modeling and analysis of components, sub-systems or systems with fidelity appropriate to the task. They begin with a general examination of the design, modeling and analysis cycle in high technology projects, emphasizing the transition from the classical islands of automation to the integrated CAE/CAD-based approach. They follow this with a discussion of lessons learned from various attempts to design and implement integrated CAE/CAD systems in scientific and engineering organizations. They then consider the requirements for design, modeling and analysis during SSC detector development, and describe an appropriate resource architecture. They close with a report on the status of the resource and present some results that are indicative of its performance. 10 refs., 7 figs

  14. Italian news coverage of radiation in the early decades of the twentieth century: A qualitative and quantitative analysis.

    Science.gov (United States)

    Candela, Andrea; Pasquarè Mariotto, Federico

    2016-02-01

    This work uses a qualitative approach coupled with a quantitative software-based methodology to examine the Italian news media coverage of radiation in the early decades of the twentieth century. We analyze 80 news stories from two of the most influential Italian newspapers from that time: La Stampa (a daily newspaper) and La Domenica del Corriere (an Italian Sunday supplement). While much of previous research on media coverage of scientific topics was generally focused on present-day news, our work revolves around the ground-breaking discovery of X-rays and radioactivity at the dawn of the last century. Our analysis aims to identify journalistic frames in the news coverage of radiation that journalists might have used to emphasize the benefits (or the risks) of the new discoveries. We also hypothesize how this kind of news coverage might have influenced public perception of technological, commercial, and public health applications of the new scientific advancements. © The Author(s) 2014.

  15. Coverage or Cover-up: A Comparison of Newspaper Coverage of the 19th Amendment and the Equal Rights Amendment.

    Science.gov (United States)

    Smith, Linda Lazier

    A study compared newspaper coverage of the women's suffrage movement in the 1920s with coverage of efforts to pass the Equal Rights Amendment in the 1970s and early 1980s, to see if the similar movements with different outcomes were treated similarly or differently by the press. A content analysis of relevant articles in the "New York…

  16. Multi-detector row computed tomography angiography of peripheral arterial disease

    International Nuclear Information System (INIS)

    Kock, Marc C.J.M.; Dijkshoorn, Marcel L.; Pattynama, Peter M.T.; Myriam Hunink, M.G.

    2007-01-01

    With the introduction of multi-detector row computed tomography (MDCT), scan speed and image quality has improved considerably. Since the longitudinal coverage is no longer a limitation, multi-detector row computed tomography angiography (MDCTA) is increasingly used to depict the peripheral arterial runoff. Hence, it is important to know the advantages and limitations of this new non-invasive alternative for the reference test, digital subtraction angiography. Optimization of the acquisition parameters and the contrast delivery is important to achieve a reliable enhancement of the entire arterial runoff in patients with peripheral arterial disease (PAD) using fast CT scanners. The purpose of this review is to discuss the different scanning and injection protocols using 4-, 16-, and 64-detector row CT scanners, to propose effective methods to evaluate and to present large data sets, to discuss its clinical value and major limitations, and to review the literature on the validity, reliability, and cost-effectiveness of multi-detector row CT in the evaluation of PAD. (orig.)

  17. Optoelectronic iron detectors for pharmaceutical flow analysis.

    Science.gov (United States)

    Rybkowska, Natalia; Koncki, Robert; Strzelak, Kamil

    2017-10-25

    Compact flow-through optoelectronic detectors fabricated by pairing of light emitting diodes have been applied for development of economic flow analysis systems dedicated for iron ions determination. Three analytical methods with different chromogens selectively recognizing iron ions have been compared. Ferrozine and ferene S based methods offer higher sensitivity and slightly lower detection limits than method with 1,10-phenantroline, but narrower ranges of linear response. Each system allows detection of iron in micromolar range of concentration with comparable sample throughput (20 injections per hour). The developed flow analysis systems have been successfully applied for determination of iron in diet supplements. The utility of developed analytical systems for iron release studies from drug formulations has also been demonstrated. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Maximum Acceptance Detector for the Fermilab Collider (MAX)

    International Nuclear Information System (INIS)

    Bjorken, James

    2003-01-01

    The authors propose a detector for the Collider which will cover the largest possible ranges of angles with electromagnetic calorimetry and charged tracking, and with hadronic calorimetry for the forward direction. The goal for the complete detector would be acceptance down to approx 1 mrad, in contrast to CDF and D0, which have coverage only to approx. 40 mrad. Because of the limitations of physical space and running time in all but B0 and D0, such a detector will have to be very compact and compatible with a variety of difficult boundary conditions. For this reason, they propose to run a test program at F0 during the second of the present Collider running period, utilizing existing calorimeters and tracking systems. A less desirable option which can be installed at E0 is also described. With luck there may be the possibility of physics from the test program as well. The final version of the detector would be installed at E0 after the main Injector upgrade. the detector is designed to study processes with relatively large cross sections. The running time requirements are thus minimal and data taking would require running a small fraction of the time with the electrostatic separators turned off

  19. Gamma-ray pulse height spectrum analysis on systems with multiple Ge detectors using spectrum summing

    Energy Technology Data Exchange (ETDEWEB)

    Killian, E.W. [Idaho National Engineering Lab., Idaho Falls, ID (United States)

    1997-11-01

    A technique has been developed at the Idaho National Engineering Laboratory to sum high resolution gamma-ray pulse spectra from systems with multiple Ge detectors. Lockheed Martin Idaho Technologies Company operates a multi-detector spectrometer configuration at the Stored Waste Examination Pilot Plant facility which is used to characterize the radionuclide contents in waste drums destined for shipment to Waste Isolation Pilot Plant. This summing technique was developed to increase the sensitivity of the system, reduce the count times required to properly quantify the radio-nuclides and provide a more consistent methodology for combining data collected from multiple detectors. In spectrometer systems with multiple detectors looking at non homogeneous waste forms it is often difficult to combine individual spectrum analysis results from each detector to obtain a meaningful result for the total waste container. This is particularly true when the counting statistics in each individual spectrum are poor. The spectrum summing technique adds the spectra collected by each detector into a single spectrum which has better counting statistics than each individual spectrum. A normal spectral analysis program can then be used to analyze the sum spectrum to obtain radio-nuclide values which have smaller errors and do not have to be further manipulated to obtain results for the total waste container. 2 refs., 2 figs.

  20. The effects of detector descoping and neutral boson mixing on new gauge boson physics at the SSC

    International Nuclear Information System (INIS)

    Hewett, J.L.; Rizzo, T.G.

    1992-06-01

    We examine how the abilities of an SDC-like detector to discover and identify the origin of a new neutral gauge boson are affected by Z 1 - Z 2 mixing and by variations in detector parameters such as lepton pair mass resolution, particle identification efficiency, and rapidity coverage. Also examined is the sensitivity of these results to variations in structure function uncertainties and uncertainties in the machine integrated luminosity. Such considerations are of importance when dealing with the issues of detector descoping and design

  1. Medicare Coverage Database

    Data.gov (United States)

    U.S. Department of Health & Human Services — The Medicare Coverage Database (MCD) contains all National Coverage Determinations (NCDs) and Local Coverage Determinations (LCDs), local articles, and proposed NCD...

  2. A New scintillator tile / fiber preshower detector for the CDF central calorimeter

    Energy Technology Data Exchange (ETDEWEB)

    Gallinaro, Michele; /Rockefeller U.; Artikov, A.; Bromberg, C.; Budagov, J.; Byrum, K.; Chang, S.; Chlachidze, G.; Goulianos, K.; Huston, J.; Iori, M.; Kim, M.; Kuhlmann,; Lami, S.; Lindgren, M.; Lytken, E.; Miller, R.; Nodulman, L.; Pauletta, G.; Penzo, A.; Proudfoot, J.; Roser, R.; /Argonne /Dubna, JINR /Fermilab /Kyungpook Natl. U. /Michigan

    2004-11-01

    A detector designed to measure early particle showers has been installed in front of the central CDF calorimeter at the Tevatron. This new preshower detector is based on scintillator tiles coupled to wavelength-shifting fibers read out by multianode photomultipliers and has a total of 3,072 readout channels. The replacement of the old gas detector was required due to an expected increase in instantaneous luminosity of the Tevatron collider in the next few years. Calorimeter coverage, jet energy resolution, and electron and photon identification are among the expected improvements. The final detector design, together with the R&D studies that led to the choice of scintillator and fiber, mechanical assembly, and quality control are presented. The detector was installed in the fall 2004 Tevatron shutdown and is expected to start collecting colliding beam data by the end of 2004. First measurements indicate a light yield of 12 photoelectrons/MIP, a more than two-fold increase over the design goals.

  3. Social Gerontology--Integrative and Territorial Aspects: A Citation Analysis of Subject Scatter and Database Coverage

    Science.gov (United States)

    Lasda Bergman, Elaine M.

    2011-01-01

    To determine the mix of resources used in social gerontology research, a citation analysis was conducted. A representative sample of citations was selected from three prominent gerontology journals and information was added to determine subject scatter and database coverage for the cited materials. Results indicate that a significant portion of…

  4. Immunisation coverage in rural-urban migrant children in low and middle-income countries (LMICs): a systematic review and meta-analysis.

    Science.gov (United States)

    Awoh, Abiyemi Benita; Plugge, Emma

    2016-03-01

    The majority of children who die from vaccine-preventable diseases (VPDs) live in low-income and-middle-income countries (LMICs). With the rapid urbanisation and rural-urban migration ongoing in LMICs, available research suggests that migration status might be a determinant of immunisation coverage in LMICs, with rural-urban migrant (RUM) children being less likely to be immunised. To examine and synthesise the data on immunisation coverage in RUM children in LMICs and to compare coverage in these children with non-migrant children. A multiple database search of published and unpublished literature on immunisation coverage for the routine Expanded Programme on Immunisation (EPI) vaccines in RUM children aged 5 years and below was conducted. Following a staged exclusion process, studies that met the inclusion criteria were assessed for quality and data extracted for meta-analysis. Eleven studies from three countries (China, India and Nigeria) were included in the review. There was substantial statistical heterogeneity between the studies, thus no summary estimate was reported for the meta-analysis. Data synthesis from the studies showed that the proportion of fully immunised RUM children was lower than the WHO bench-mark of 90% at the national level. RUMs were also less likely to be fully immunised than the urban-non-migrants and general population. For the individual EPI vaccines, all but two studies showed lower immunisation coverage in RUMs compared with the general population using national coverage estimates. This review indicates that there is an association between rural-urban migration and immunisation coverage in LMICs with RUMs being less likely to be fully immunised than the urban non-migrants and the general population. Specific efforts to improve immunisation coverage in this subpopulation of urban residents will not only reduce morbidity and mortality from VPDs in migrants but will also reduce health inequity and the risk of infectious disease

  5. General structure of the GRAND program for analysis of the data from a neutrino detector

    International Nuclear Information System (INIS)

    Zhigunov, V.P.; Kulikov, V.A.; Mukhin, S.A.; Naumov, V.L.; Platonov, V.G.; Spiridonov, A.A.

    1985-01-01

    The general structure of the GRAND (Global Result Analysis for Neutrino Detector) program used for geometrical and kinematic reconstruction of events recorded by a neutrino detector is considered. The detector consists of a calorimeter-target, a shower electron and γ detector and a magnetic spectrometer. While developing the GRAND program the multivariance (different types of the computers used), availability of various algorithms for solving the same problem, solution of separate particlular problems within the frames of one program are taken into account. The KERNLIB library and the HBOOK, ZBOOK, EPIO and FFREAD subroutine packages are used while creating the program as basic libraries

  6. A New Virtual Point Detector Concept for a HPGe detector

    International Nuclear Information System (INIS)

    Byun, Jong In; Yun, Ju Yong

    2009-01-01

    For last several decades, the radiation measurement and radioactivity analysis techniques using gamma detectors have been well established. Especially , the study about the detection efficiency has been done as an important part of gamma spectrometry. The detection efficiency depends strongly on source-to-detector distance. The detection efficiency with source-to-detector distance can be expressed by a complex function of geometry and physical characteristics of gamma detectors. In order to simplify the relation, a virtual point detector concept was introduced by Notea. Recently, further studies concerning the virtual point detector have been performed. In previous other works the virtual point detector has been considered as a fictitious point existing behind the detector end cap. However the virtual point detector position for the front and side of voluminous detectors might be different due to different effective central axis of them. In order to more accurately define the relation, therefore, we should consider the virtual point detector for the front as well as side and off-center of the detector. The aim of this study is to accurately define the relation between the detection efficiency and source-to-detector distance with the virtual point detector. This paper demonstrates the method to situate the virtual point detectors for a HPGe detector. The new virtual point detector concept was introduced for three area of the detector and its characteristics also were demonstrated by using Monte Carlo Simulation method. We found that the detector has three virtual point detectors except for its rear area. This shows that we should consider the virtual point detectors for each area when applying the concept to radiation measurement. This concept can be applied to the accurate geometric simplification for the detector and radioactive sources.

  7. Print News Coverage of School-Based HPV Vaccine Mandate

    Science.gov (United States)

    Casciotti, Dana; Smith, Katherine C.; Andon, Lindsay; Vernick, Jon; Tsui, Amy; Klassen, Ann C.

    2015-01-01

    BACKGROUND In 2007, legislation was proposed in 24 states and the District of Columbia for school-based HPV vaccine mandates, and mandates were enacted in Texas, Virginia, and the District of Columbia. Media coverage of these events was extensive, and media messages both reflected and contributed to controversy surrounding these legislative activities. Messages communicated through the media are an important influence on adolescent and parent understanding of school-based vaccine mandates. METHODS We conducted structured text analysis of newspaper coverage, including quantitative analysis of 169 articles published in mandate jurisdictions from 2005-2009, and qualitative analysis of 63 articles from 2007. Our structured analysis identified topics, key stakeholders and sources, tone, and the presence of conflict. Qualitative thematic analysis identified key messages and issues. RESULTS Media coverage was often incomplete, providing little context about cervical cancer or screening. Skepticism and autonomy concerns were common. Messages reflected conflict and distrust of government activities, which could negatively impact this and other youth-focused public health initiatives. CONCLUSIONS If school health professionals are aware of the potential issues raised in media coverage of school-based health mandates, they will be more able to convey appropriate health education messages, and promote informed decision-making by parents and students. PMID:25099421

  8. Contributions for the application of a phoswich detector on the analysis of environmental samples

    International Nuclear Information System (INIS)

    Dalaqua Junior, L.

    1989-01-01

    The characteristics of a phoswich detector and the parameters of the pulse shape descrimination system are evaluated aiming the application on environmental analysis by direct low level gamma ray spectrometry. The calibration curves and adjustments for the pulse discrimination, detector resolution and homogeneity measurements are presented. Background reduction and the 210 Pb detection eficiency on evaporated sources are evaluated. The results obtained demonstrates the application potentiality on the analysis of environmental samples due to a high detection eficiency and good geometry conditions to the measurements. (author) [pt

  9. Status of the ATLAS Pixel Detector and its performance after three years of operation

    CERN Document Server

    Favareto, A; The ATLAS collaboration

    2012-01-01

    The ATLAS Pixel Detector is the innermost detector of the ATLAS experiment at the Large Hadron Collider at CERN, providing high-resolution measurements of charged particle tracks in the high radiation environment close to the collision region. This capability is very important for the identification and measurement of proper decay times of long-lived particles such as b-hadrons, and thus vital for the ATLAS physics program. The detector provides hermetic coverage with three cylindrical layers and three layers of forward and backward pixel detectors. It consists of approximately 80 million pixels that are individually read out via chips bump-bonded to 1744 n-in-n silicon substrates. The detector performance is excellent: ~96 % of the pixels are operational, noise occupancy and hit efficiency exceed the design specification, and a good alignment allows high quality track resolution

  10. Status of the ATLAS Pixel Detector and its performance after three years of operation

    CERN Document Server

    Favareto, A; The ATLAS collaboration

    2012-01-01

    The ATLAS Pixel Detector is the innermost detector of the ATLAS experiment at the Large Hadron Collider at CERN, providing high-resolution measurements of charged particle tracks in the high radiation environment close to the collision region. This capability is very important for the identification and measurement of proper decay times of long-lived particles such as b-hadrons, and thus vital for the ATLAS physics program. The detector provides hermetic coverage with three cylindrical layers and three layers of forward and backward pixel detectors. It consists of approximately 80 million pixels that are individually read out via chips bump-bonded to 1744 n-in-n silicon substrates. The detector performance is excellent: ~96% of the pixels are operational, noise occupancy and hit efficiency exceed the design specification, and a good alignment allows high quality track resolution.

  11. Analysis of changes in environmental radiation, and three types of environmental radiation detector performance comparisons

    International Nuclear Information System (INIS)

    Park, J.H; Seo, J.H; Park, S.M; Yu, B.N; Park, J.H; Joo, K.S

    2013-06-01

    High-pressure ion chamber (GE Reuter-Stokes, HPIC), accuracy is high but the high price and do not have the ability nuclide analysis is a disadvantage. NaI(Tl) and PMT scintillation detector of radioactive materials can be divided. Environmental radiation measurements using a semiconductor with SiPM detector PMT to replace the value of the results were compared. SiPM detector using radiation environment were measured in the field to verify the accuracy and energy resolution. SiPMs performance as environmental radiation measurement equipment and radioactive material distinction as a personal dosimeter based technology, using the above results were prepared. The interest on the environmental radiation due to the Fukushima power plant crisis in Japan has been growing concern about the radiation environment of the relatively close proximity Korea is a very heightened state. Could be confirmed in the radiation environment of nuclear power plants around the analysis and performance of the next generation of environmental radiation meter. Fukushima power plants accident after 2 years, the equipment installed by this analysis meets the performance as a radiation detector could be confirmed as follows. CANA Inc. developed by radionuclides classification of using man-made and natural radionuclides and man-made radionuclides separated, ensure the value of the results were analyzed. Could be and alternative to the conventional detector energy resolution ( 137 CS<15%) and linearity (<15%) to satisfy the performance requirements of the measurement result of environmental radiation detector is considered. SiPM radiation environment changes and HPIC and NaI(TI) scintillation detector installed in Korea of the Fukushima power plant after the accident, radiation environment using a small alternative was to verify the accuracy of the measuring equipment. A big difference in performance as invisible by comparison with the large detector Assay miniaturization rough as a personal

  12. Performance study of hybrid photon detectors for the LHCb RICH

    CERN Document Server

    Kanaya, N; Gys, Thierry; Piedigrossi, D; Wyllie, K

    2005-01-01

    The LHCb experiment is designed to study CP violation and rare phenomena of B mesons with very high accuracy. The LHCb RICH detectors are essential for positive kaon identification, and several strict demands are required of its photon detectors to achieve excellent particle identification performance. In particular, they should have good single photon sensitivity for visible and UV wavelengths and large coverage with fine granularity. HPDs have been developed to meet these requirements in collaboration with industry. They have now been chosen as the photon detector for LHCb, and pre-series tubes are under test prior to mass production. At the same time, more detailed studies are on-going to understand more deeply their characteristics. The result of various performance tests of these tubes as well as the fraction of light reflection in the HPD are described in this paper.

  13. Constructing identities in the media: newspaper coverage analysis of a major UK Clostridium difficile outbreak.

    Science.gov (United States)

    Burnett, Emma; Johnston, Bridget; Corlett, Joanne; Kearney, Nora

    2014-07-01

    To examine how a major Clostridium difficile outbreak in the UK was represented in the media. Clostridium difficile is a serious health care-associated infection with significant global prevalence. As major outbreaks have continued to occur worldwide over the last few decades, it has also resulted in increasing media coverage. Newspaper journalists are, however, frequently criticized for sensationalized and inaccurate reporting and alarming the public. Despite such criticisms, nothing is known about how the media frame Clostridium difficile related coverage. Qualitative interpretive descriptive study. An interpretive analysis of newspaper articles from the national press that reported about the outbreak from the first day of coverage over 3 weeks (12 June-3 July 2008). Twenty-eight newspaper articles were included in the study from tabloids, broadsheets, a regional and a Sunday newspaper. Monster and war metaphors were frequently adopted to portray the severity of Clostridium difficile and the impact it can have on patient safety. In addition, the positioning of the affected patients, their families, healthcare professionals and the Government produced representations of victims, villains and heroes. This subsequently evoked notions of vulnerability, blame and conflict. The media are and will remain critical convectors of public information and, as such, are hugely influential in risk perceptions and responses. Rather than simply dismissing media coverage, further understanding around how such stories in specific contexts are constructed and represented is needed so that it can help inform future communication and management strategies. © 2013 John Wiley & Sons Ltd.

  14. Artificial neural network based pulse-shape analysis for cryogenic detectors operated in CRESST-II

    Energy Technology Data Exchange (ETDEWEB)

    Zoeller, Andreas [Physik-Department and Excellence Cluster Universe, Technische Universitaet Muenchen, D-85747 Garching (Germany); Collaboration: CRESST-Collaboration

    2016-07-01

    In this talk we report on results of a pulse-shape analysis of cryogenic detectors based on artificial neural networks. To train the neural network a large amount of pulses with known properties are necessary. Therefore, a data-driven simulation used to generate these sets will be explained. The presented analysis shows an excellent discrimination performance even down to the energy threshold. The method is applied to several detectors, among them is the module with the lowest threshold (307eV) operated in CRESST-II phase 2. The performed blind analysis of this module confirms the substantially enhanced sensitivity for light dark matter published in 2015.

  15. Comparative analysis for the measured and the predicted relative sensitivity of rhodium In core detector

    International Nuclear Information System (INIS)

    Moon, Sang Rae; Cha, Kyoon Ho; Bae, Seong Man

    2012-01-01

    Self-powered neutron detector (SPND) is widely used as in-core flux monitoring in nuclear power plants. OPR1000 has applied a rhodium (Rh) as the emitter of the SPND. The SPND contains a neutron-sensitive metallic emitter surrounded by a ceramic insulator. When capturing a neutron, the Rh will be decayed by emitting some electrons which is crossing the sheath and produce current. This current can be measured externally using pico-ammeter. The sensitivity of detectors is closely related with the geometry and material of the detectors. The lifetime of in-core detector is determined by calculating the relative sensitivity of Rh detector. It is required that the Rh detector should be replaced before the burn-up of Rh detector has reached 66% of its original compositions. To predict Rh detector's relative sensitivity ANC code, advanced nodal code capable of two-dimensional and three-dimensional calculations, is used. It is determined that the Rh detectors should be replaced on the basis of the predicted sensitivity value calculated by ANC code. When evaluating the life of Rh detectors using ANC code, it is assumed that the uncertainty of the sensitivity calculation include the measurement error of 5%. As a result of the analysis of measured and predicted data for the Rh detector's relative sensitivity, it is possible to reduce the assumed uncertainty

  16. Comparative analysis for the measured and the predicted relative sensitivity of rhodium In core detector

    Energy Technology Data Exchange (ETDEWEB)

    Moon, Sang Rae; Cha, Kyoon Ho; Bae, Seong Man [Nuclear Reactor Safety Lab., KHNP Central Research Institute, Daejeon (Korea, Republic of)

    2012-10-15

    Self-powered neutron detector (SPND) is widely used as in-core flux monitoring in nuclear power plants. OPR1000 has applied a rhodium (Rh) as the emitter of the SPND. The SPND contains a neutron-sensitive metallic emitter surrounded by a ceramic insulator. When capturing a neutron, the Rh will be decayed by emitting some electrons which is crossing the sheath and produce current. This current can be measured externally using pico-ammeter. The sensitivity of detectors is closely related with the geometry and material of the detectors. The lifetime of in-core detector is determined by calculating the relative sensitivity of Rh detector. It is required that the Rh detector should be replaced before the burn-up of Rh detector has reached 66% of its original compositions. To predict Rh detector's relative sensitivity ANC code, advanced nodal code capable of two-dimensional and three-dimensional calculations, is used. It is determined that the Rh detectors should be replaced on the basis of the predicted sensitivity value calculated by ANC code. When evaluating the life of Rh detectors using ANC code, it is assumed that the uncertainty of the sensitivity calculation include the measurement error of 5%. As a result of the analysis of measured and predicted data for the Rh detector's relative sensitivity, it is possible to reduce the assumed uncertainty.

  17. In-beam evaluation of a medium-size Resistive-Plate WELL gaseous particle detector

    CERN Document Server

    Moleri, L.

    2016-09-27

    In-beam evaluation of a fully-equipped medium-size 30$\\times$30 cm$^2$ Resistive Plate WELL (RPWELL) detector is presented. It consists here of a single element gas-avalanche multiplier with Semitron ESD225 resistive plate, 1 cm$^2$ readout pads and APV25/SRS electronics. Similarly to previous results with small detector prototypes, stable operation at high detection efficiency (>98%) and low average pad multiplicity (~1.2) were recorded with 150 GeV muon and high-rate pion beams, in Ne/(5%CH$_4$), Ar/(5%CH$_4$) and Ar/(7%CO$_2$). This is an important step towards the realization of robust detectors suitable for applications requiring large-area coverage; among them Digital Hadron Calorimetry.

  18. SiPM photosensors and fast timing readout for the Barrel Time-of-Flight detector in bar PANDA

    Science.gov (United States)

    Suzuki, K.

    2018-03-01

    The Barrel Time-of-Flight detector system will be installed in the upcoming bar PANDA experiment at FAIR in Germany. The detector has a barrel shape of phi=0.5 m and 1.8 m long, covering about 5 m2, which corresponds to the laboratory polar angle coverage of 22oPANDA Barrel Time-of-Flight detector are presented. The test shows that the current design fulfils satisfactorily the required timing performance (σt~ 56 ps) and the timing performance depends little on the hit position on the surface.

  19. Detector applications

    International Nuclear Information System (INIS)

    Pehl, R.H.

    1977-10-01

    Semiconductor detectors are now applied to a very wide range of problems. The combination of relatively low cost, excellent energy resolution, and simultaneous broad energy-spectrum analysis is uniquely suited to many applications in both basic and applied physics. Alternative techniques, such as magnetic spectrometers for charged-particle spectroscopy, while offering better energy resolution, are bulky, expensive, and usually far more difficult to use. Furthermore, they do not directly provide the broad energy-spectrum measurements easily accomplished using semiconductor detectors. Scintillation detectors, which are approximately equivalent to semiconductor detectors in convenience and cost, exhibit 10 to 100 times worse energy resolution. However, their high efficiency and large potential size recommend their use in some measurements

  20. Media Coverage of Nuclear Energy after Fukushima

    International Nuclear Information System (INIS)

    Oltra, C.; Roman, P.; Prades, A.

    2013-01-01

    This report presents the main findings of a content analysis of printed media coverage of nuclear energy in Spain before and after the Fukushima accident. Our main objective is to understand the changes in the presentation of nuclear fission and nuclear fusion as a result of the accident in Japan. We specifically analyze the volume of coverage and thematic content in the media coverage for nuclear fusion from a sample of Spanish print articles in more than 20 newspapers from 2008 to 2012. We also analyze the media coverage of nuclear energy (fission) in three main Spanish newspapers one year before and one year after the accident. The results illustrate how the media contributed to the presentation of nuclear power in the months before and after the accident. This could have implications for the public understanding of nuclear power. (Author)

  1. Media Coverage of Nuclear Energy after Fukushima

    Energy Technology Data Exchange (ETDEWEB)

    Oltra, C.; Roman, P.; Prades, A.

    2013-07-01

    This report presents the main findings of a content analysis of printed media coverage of nuclear energy in Spain before and after the Fukushima accident. Our main objective is to understand the changes in the presentation of nuclear fission and nuclear fusion as a result of the accident in Japan. We specifically analyze the volume of coverage and thematic content in the media coverage for nuclear fusion from a sample of Spanish print articles in more than 20 newspapers from 2008 to 2012. We also analyze the media coverage of nuclear energy (fission) in three main Spanish newspapers one year before and one year after the accident. The results illustrate how the media contributed to the presentation of nuclear power in the months before and after the accident. This could have implications for the public understanding of nuclear power. (Author)

  2. Cost-Utility Analysis of Extending Public Health Insurance Coverage to Include Diabetic Retinopathy Screening by Optometrists.

    Science.gov (United States)

    van Katwyk, Sasha; Jin, Ya-Ping; Trope, Graham E; Buys, Yvonne; Masucci, Lisa; Wedge, Richard; Flanagan, John; Brent, Michael H; El-Defrawy, Sherif; Tu, Hong Anh; Thavorn, Kednapa

    2017-09-01

    Diabetic retinopathy (DR) is one of the leading causes of vision loss and blindness in Canada. Eye examinations play an important role in early detection. However, DR screening by optometrists is not always universally covered by public or private health insurance plans. This study assessed whether expanding public health coverage to include diabetic eye examinations for retinopathy by optometrists is cost-effective from the perspective of the health care system. We conducted a cost-utility analysis of extended coverage for diabetic eye examinations in Prince Edward Island to include examinations by optometrists, not currently publicly covered. We used a Markov chain to simulate disease burden based on eye examination rates and DR progression over a 30-year time horizon. Results were presented as an incremental cost per quality-adjusted life year (QALY) gained. A series of one-way and probabilistic sensitivity analyses were performed. Extending public health coverage to eye examinations by optometrists was associated with higher costs ($9,908,543.32) and improved QALYs (156,862.44), over 30 years, resulting in an incremental cost-effectiveness ratio of $1668.43/QALY gained. Sensitivity analysis showed that the most influential determinants of the results were the cost of optometric screening and selected utility scores. At the commonly used threshold of $50,000/QALY, the probability that the new policy was cost-effective was 99.99%. Extending public health coverage to eye examinations by optometrists is cost-effective based on a commonly used threshold of $50,000/QALY. Findings from this study can inform the decision to expand public-insured optometric services for patients with diabetes. Copyright © 2017 International Society for Pharmacoeconomics and Outcomes Research (ISPOR). Published by Elsevier Inc. All rights reserved.

  3. A multi-channel photometric detector for multi-component analysis in flow injection analysis.

    Science.gov (United States)

    Tan, A; Huang, J; Geng, L; Xu, J; Zhao, X

    1994-01-01

    The detector, a multi-channel photometric detector, described in this paper was developed using multi-wavelength LEDs (light emitting diode) and phototransistors for absorbance measurement controlled by an Intel 8031 8-bit single chip microcomputer. Up to four flow cells can be attached to the detector. The LEDs and phototransistors are both inexpensive, and reliable. The results given by the detector for simultaneous determination of trace amounts of cobalt and cadmium in zinc sulphate electrolyte are reported. Because of the newly developed detector, this approach employs much less hardware apparatus than by employing conventional photometric detectors.

  4. Head of detector for multi-element analysis

    International Nuclear Information System (INIS)

    Frynta, Z.

    1983-01-01

    The detector head mounted on the scintillation counter consists of a hollow hexagonal rotary support axially arranged with the photomultiplier of the scintillation counter. In the walls of the hexagonal rotary support there are openings in which are inserted absorption filters. The mounting of the absorption filters on the rotary support allows the analysis of a greater number of elements without the dismantling of the head and the replacement of filters. The suitable geometry of the head is retained so that it is possible to insert the head into the hollows similarly as the scintillation counter. (J.P.)

  5. News Coverage of Child Sexual Abuse and Prevention, 2007-2009

    Science.gov (United States)

    Mejia, Pamela; Cheyne, Andrew; Dorfman, Lori

    2012-01-01

    News media coverage of child sexual abuse can help policymakers and the public understand what must be done to prevent future abuse, but coverage tends to focus on extreme cases. This article presents an analysis of newspaper coverage from 2007 to 2009 to describe how the daily news presents and frames day-to-day stories about child sexual abuse.…

  6. Detector Simulation and WIMP Search Analysis for the Cryogenic Dark Matter Search Experiment

    Energy Technology Data Exchange (ETDEWEB)

    McCarthy, Kevin [Massachusetts Inst. of Technology (MIT), Cambridge, MA (United States)

    2013-06-01

    Astrophysical and cosmological measurements on the scales of galaxies, galaxy clusters, and the universe indicate that 85% of the matter in the universe is composed of dark matter, made up of non-baryonic particles that interact with cross-sections on the weak scale or lower. Hypothetical Weakly Interacting Massive Particles, or WIMPs, represent a potential solution to the dark matter problem, and naturally arise in certain Standard Model extensions. The Cryogenic Dark Matter Search (CDMS) collaboration aims to detect the scattering of WIMP particles from nuclei in terrestrial detectors. Germanium and silicon particle detectors are deployed in the Soudan Underground Laboratory in Minnesota. These detectors are instrumented with phonon and ionization sensors, which allows for discrimination against electromagnetic backgrounds, which strike the detector at rates orders of magnitude higher than the expected WIMP signal. This dissertation presents the development of numerical models of the physics of the CDMS detectors, implemented in a computational package collectively known as the CDMS Detector Monte Carlo (DMC). After substantial validation of the models against data, the DMC is used to investigate potential backgrounds to the next iteration of the CDMS experiment, known as SuperCDMS. Finally, an investigation of using the DMC in a reverse Monte Carlo analysis of WIMP search data is presented.

  7. Analysis of the performance capability of an infrared interior intrusion detector

    International Nuclear Information System (INIS)

    Dunn, D.R.

    1977-01-01

    Component performances are required by the LLL assessment procedure for material control and accounting (MC and A) systems. Monitors are an example of an MC and A component whose functions are to process measurements or observations for purposes of detecting abnormalities. This report develops a methodology for characterizing the performance of a class of infrared (IR) interior intrusion monitors or detectors. The methodology is developed around a specific commercial IR detector, the InfrAlarm, manufactured by Barnes Engineering Company (Models 19-124 and 19-115A). Statistical detection models for computing probabilities of detection and false alarms were derived, and the performance capability of the InfrAlarm IR detector was shown using these measures. The results obtained in the performance analysis show that the detection capability of the InfrAlarm is excellent (approx. 1), with very low false alarm rates, for a wide range in target characteristics. These results should be representative and particularly for non-hostile environments

  8. Autologous but not Fibrin Sealant Patches for Stump Coverage Reduce Clinically Relevant Pancreatic Fistula in Distal Pancreatectomy: A Systematic Review and Meta-analysis.

    Science.gov (United States)

    Weniger, Maximilian; D'Haese, Jan Goesta; Crispin, Alexander; Angele, Martin Kurt; Werner, Jens; Hartwig, Werner

    2016-11-01

    Postoperative pancreatic fistula (POPF) causes significant morbidity and mortality after distal pancreatectomy. Patch coverage of the pancreatic stump is often used with the intention to prevent POPF. Despite numerous investigations, the effects of patch coverage remain unclear. The present meta-analysis aims to clarify the effects of patch coverage in distal pancreatectomy on the incidence of POPF. A systematic search of MEDLINE/PubMed and the Cochrane Database according to the PRISMA Statement was performed. Subsequently a meta-analysis on rates and overall incidence of POPF and length of hospital stay was carried out. By applying the inverse variance weighting method, the combined effect size and 95 % confidence interval were calculated. Heterogeneity was assessed using I 2 statistics. Five randomized controlled trials and six observational clinical studies were included for final analysis. A cumulative incidence of 43 % of POPF grades A-C was identified. Patch coverage in distal pancreatectomy is significantly associated with a decreased rate of POPF grade C (p = 0.006). Patches of autologous vascularized tissue significantly reduce the overall incidence of POPF (p = 0.04) and clinically relevant POPF grade B and C (p = 0.002). Fibrin sealant patches do not influence rates of POPF after distal pancreatectomy. None of the outcomes evaluated showed adverse results for the patch group. Patch coverage after distal pancreatectomy can reduce the rate of POPF. Patch coverage with autologous vascularized tissue but not fibrin sealant patches may be used to reduce clinically relevant POPF and postoperative morbidity in distal pancreatectomy.

  9. Comparison Of Irms Delhi Methodology With Who Methodology On Immunization Coverage

    Directory of Open Access Journals (Sweden)

    Singh Padam

    1996-01-01

    Full Text Available Research question: What are the merits of IRMS Model over WHO Model for Coverage Evaluation Survey? Which method is superior and appropriate for coverage evolution survey of immunization in our setting? Objective: To compare IRMS Delhi methodology with WHO methodology on Immunization Coverage. Study Design: Cross-Sectional Setting: Urban and Rural both. Participants: Mothers& Children Sample Size: 300 children between 1-2 years and 300 mothers in rural areas and 75 children and 75 mothers in urban areas. Study Variables: Rural, Urban, Cast-Group, Size of the stratum, Literacy, Sex and Cost effectiveness. Outcome Variables: Coverage level of immunization. Analysis: Routine Statistical Analysis. Results: IRMS developed methodology scores better rating over WHO methodology, especially when coverage evolution is attempted in medium size villages with existence of socio-economic seggregation-which remains the main characteristic of the Indian villages.

  10. The performance of silicon detectors for the SiliPET project: A small animal PET scanner based on stacks of silicon detectors

    International Nuclear Information System (INIS)

    Auricchio, Natalia; Domenico, Giovanni di; Zavattini, Guido; Milano, Luciano; Malaguti, Roberto

    2011-01-01

    We propose a new scanner for small animal Positron Emission Tomography (PET) based on stacks of double sided silicon detectors. Each stack is made of 40 planar detectors with dimension 60x60x1 mm 3 and 128 orthogonal strips on both sides to read the two coordinates of interaction, the third being the detector number in the stack. Multiple interactions in a stack are discarded by an exclusive OR applied between each detector plane of a stack. In this way we achieve a precise determination of the interaction point of the two 511 keV photons. The reduced dimensions of the scanner also improve the solid angle coverage resulting in a high sensitivity. Preliminary results were obtained with MEGA prototype tracker (11 double sided Si detector layers), divided into two stacks 2 cm apart made of, respectively, 5 and 6 prototype layers, placing a small spherical 22 Na source in different positions. We report on the results, spatial resolution, imaging and timing performances obtained with double sided silicon detectors, manufactured by ITC-FBK, having an active area of 3x3 cm 2 , thickness of 1 mm and a strip pitch of 500μm. Two different strip widths of 300 and 200μm equipped with 64 orthogonal p and n strips on opposite sides were read out with the VATAGP2.5 ASIC, a 128-channel 'general purpose' charge sensitive amplifier.

  11. Analysis of the passive heat removal enhancement for AP1000 containment due to the partially wetted coverage

    Energy Technology Data Exchange (ETDEWEB)

    Li, Cheng, E-mail: 510395453@qq.com [State Nuclear Power Technology Research & Development Center, 102209 Beijing (China); Li, Le [Tsinghua University, Institute of Nuclear and New Energy Technology, 100084 Beijing (China); Li, Junming [Tsinghua University, Key Laboratory for Thermal Science and Power Engineering of Ministry of Education, Department of Thermal Engineering, Beijing 100084 (China); Zhang, Yajun [Tsinghua University, Institute of Nuclear and New Energy Technology, 100084 Beijing (China); Li, Zhihui [State Nuclear Power Technology Research & Development Center, 102209 Beijing (China)

    2017-03-15

    Highlights: • Heat removal by steam condensation, thermal conduction and evaporation is the most important scheme for AP1000 PCCS. Traditionally, studies on containment wall condensation and evaporation have been widely made, while it lacks studies on the shell two-dimension (2-D) thermal conduction. Currently, based on the known heat and mass transfer correlations and the phenomenon from water wetted coverage test, the physical model for 2-D thermal conduction is given and numerical simulation is then made. By discussions, it forms the following highlights. • The partially wetted surface can enhance the whole heat transfer process (including inner condensation, wall thermal conduction and outside cooling) and the maximum enhancement factor can be as large as 63%. There is an enhancement peak at around dry strip fraction a = 90%. When L is less than 0.03 m, its influence on heat transfer is small and the enhancement is mainly affected by dry coverage. However, for larger L, both α and L contribute much to larger enhancement. • Location at the spring line is often used for safety analysis and the dry strip fraction there for AP1000 is mainly at 10%–80%. Accordingly, further analysis is made on L (0.03 < L < 0.3) and a fitting expression is given for α = 10%–80%. It could be used to improve the corresponding software and it could also be used for containment scaling-down criteria analysis. - Abstract: AP1000 containment uses the water film evaporation, coupled with containment inner condensation, to remove the core decay heat. However, water film cannot fully cover heat transfer surface and dry-wetted strips appear. As a result, heat transfer within the containment shell is a two-dimension thermal conduction. Current work numerically studied the AP1000 heat removal enhancement due to the partially wetted coverage phenomenon. It used the evaporation and condensation boundary conditions and Fluent software to calculate the local heat fluxes and their

  12. Analysis of the passive heat removal enhancement for AP1000 containment due to the partially wetted coverage

    International Nuclear Information System (INIS)

    Li, Cheng; Li, Le; Li, Junming; Zhang, Yajun; Li, Zhihui

    2017-01-01

    Highlights: • Heat removal by steam condensation, thermal conduction and evaporation is the most important scheme for AP1000 PCCS. Traditionally, studies on containment wall condensation and evaporation have been widely made, while it lacks studies on the shell two-dimension (2-D) thermal conduction. Currently, based on the known heat and mass transfer correlations and the phenomenon from water wetted coverage test, the physical model for 2-D thermal conduction is given and numerical simulation is then made. By discussions, it forms the following highlights. • The partially wetted surface can enhance the whole heat transfer process (including inner condensation, wall thermal conduction and outside cooling) and the maximum enhancement factor can be as large as 63%. There is an enhancement peak at around dry strip fraction a = 90%. When L is less than 0.03 m, its influence on heat transfer is small and the enhancement is mainly affected by dry coverage. However, for larger L, both α and L contribute much to larger enhancement. • Location at the spring line is often used for safety analysis and the dry strip fraction there for AP1000 is mainly at 10%–80%. Accordingly, further analysis is made on L (0.03 < L < 0.3) and a fitting expression is given for α = 10%–80%. It could be used to improve the corresponding software and it could also be used for containment scaling-down criteria analysis. - Abstract: AP1000 containment uses the water film evaporation, coupled with containment inner condensation, to remove the core decay heat. However, water film cannot fully cover heat transfer surface and dry-wetted strips appear. As a result, heat transfer within the containment shell is a two-dimension thermal conduction. Current work numerically studied the AP1000 heat removal enhancement due to the partially wetted coverage phenomenon. It used the evaporation and condensation boundary conditions and Fluent software to calculate the local heat fluxes and their

  13. Societal Implications of Health Insurance Coverage for Medically Necessary Services in the U.S. Transgender Population: A Cost-Effectiveness Analysis.

    Science.gov (United States)

    Padula, William V; Heru, Shiona; Campbell, Jonathan D

    2016-04-01

    Recently, the Massachusetts Group Insurance Commission (GIC) prioritized research on the implications of a clause expressly prohibiting the denial of health insurance coverage for transgender-related services. These medically necessary services include primary and preventive care as well as transitional therapy. To analyze the cost-effectiveness of insurance coverage for medically necessary transgender-related services. Markov model with 5- and 10-year time horizons from a U.S. societal perspective, discounted at 3% (USD 2013). Data on outcomes were abstracted from the 2011 National Transgender Discrimination Survey (NTDS). U.S. transgender population starting before transitional therapy. No health benefits compared to health insurance coverage for medically necessary services. This coverage can lead to hormone replacement therapy, sex reassignment surgery, or both. Cost per quality-adjusted life year (QALY) for successful transition or negative outcomes (e.g. HIV, depression, suicidality, drug abuse, mortality) dependent on insurance coverage or no health benefit at a willingness-to-pay threshold of $100,000/QALY. Budget impact interpreted as the U.S. per-member-per-month cost. Compared to no health benefits for transgender patients ($23,619; 6.49 QALYs), insurance coverage for medically necessary services came at a greater cost and effectiveness ($31,816; 7.37 QALYs), with an incremental cost-effectiveness ratio (ICER) of $9314/QALY. The budget impact of this coverage is approximately $0.016 per member per month. Although the cost for transitions is $10,000-22,000 and the cost of provider coverage is $2175/year, these additional expenses hold good value for reducing the risk of negative endpoints--HIV, depression, suicidality, and drug abuse. Results were robust to uncertainty. The probabilistic sensitivity analysis showed that provider coverage was cost-effective in 85% of simulations. Health insurance coverage for the U.S. transgender population is affordable

  14. Neutron-gamma discrimination by pulse analysis with superheated drop detector

    International Nuclear Information System (INIS)

    Das, Mala; Seth, S.; Saha, S.; Bhattacharya, S.; Bhattacharjee, P.

    2010-01-01

    Superheated drop detector (SDD) consisting of drops of superheated liquid of halocarbon is irradiated to neutrons and gamma-rays from 252 Cf fission neutron source and 137 Cs gamma source, respectively, separately. Analysis of pulse height of signals at the neutron and gamma-ray sensitive temperature provides significant information on the identification of neutron and gamma-ray induced events.

  15. Scalable Coverage Maintenance for Dense Wireless Sensor Networks

    Directory of Open Access Journals (Sweden)

    Jun Lu

    2007-06-01

    Full Text Available Owing to numerous potential applications, wireless sensor networks have been attracting significant research effort recently. The critical challenge that wireless sensor networks often face is to sustain long-term operation on limited battery energy. Coverage maintenance schemes can effectively prolong network lifetime by selecting and employing a subset of sensors in the network to provide sufficient sensing coverage over a target region. We envision future wireless sensor networks composed of a vast number of miniaturized sensors in exceedingly high density. Therefore, the key issue of coverage maintenance for future sensor networks is the scalability to sensor deployment density. In this paper, we propose a novel coverage maintenance scheme, scalable coverage maintenance (SCOM, which is scalable to sensor deployment density in terms of communication overhead (i.e., number of transmitted and received beacons and computational complexity (i.e., time and space complexity. In addition, SCOM achieves high energy efficiency and load balancing over different sensors. We have validated our claims through both analysis and simulations.

  16. Health insurance coverage among women in Indonesia's major cities: A multilevel analysis.

    Science.gov (United States)

    Christiani, Yodi; Byles, Julie E; Tavener, Meredith; Dugdale, Paul

    2017-03-01

    We examined women's access to health insurance in Indonesia. We analyzed IFLS-4 data of 1,400 adult women residing in four major cities. Among this population, the health insurance coverage was 24%. Women who were older, involved in paid work, and with higher education had greater access to health insurance (p health insurance across community levels (Median Odds Ratios = 3.40). Given the importance of health insurance for women's health, strategies should be developed to expand health insurance coverage among women in Indonesia, including the disparities across community levels. Such problems might also be encountered in other developing countries with low health insurance coverage.

  17. An Analysis of the Control Hierarchy Modeling of the CMS Detector Control System

    CERN Document Server

    Ling Hwong, Yi

    2010-01-01

    The supervisory level of the Detector Control System (DCS) of the CMS experiment is implemented using Finite State Machines (FSM), which model the behaviors and control the operations of all the sub-detectors and support services. The FSM tree of the whole CMS experiment consists of more than 30.000 nodes. An analysis of a system of such size is a complex task but is a crucial step towards the improvement of the overall performance of the FSM system. This paper presents the analysis of the CMS FSM system using the micro Common Representation Language 2 (mcrl2) methodology. Individual mCRL2 models are obtained for the FSM systems of the CMS sub-detectors using the ASF+SDF automated translation tool. Different mCRL2 operations are applied to the mCRL2 models. A mCRL2 simulation tool is used to closer examine the system. Visualization of a system based on the exploration of its state space is enabled with a mCRL2 tool. Requirements such as command and state propagation are expressed using modal mu-calculus and c...

  18. Target Coverage in Wireless Sensor Networks with Probabilistic Sensors

    Science.gov (United States)

    Shan, Anxing; Xu, Xianghua; Cheng, Zongmao

    2016-01-01

    Sensing coverage is a fundamental problem in wireless sensor networks (WSNs), which has attracted considerable attention. Conventional research on this topic focuses on the 0/1 coverage model, which is only a coarse approximation to the practical sensing model. In this paper, we study the target coverage problem, where the objective is to find the least number of sensor nodes in randomly-deployed WSNs based on the probabilistic sensing model. We analyze the joint detection probability of target with multiple sensors. Based on the theoretical analysis of the detection probability, we formulate the minimum ϵ-detection coverage problem. We prove that the minimum ϵ-detection coverage problem is NP-hard and present an approximation algorithm called the Probabilistic Sensor Coverage Algorithm (PSCA) with provable approximation ratios. To evaluate our design, we analyze the performance of PSCA theoretically and also perform extensive simulations to demonstrate the effectiveness of our proposed algorithm. PMID:27618902

  19. Effects of coverage gap reform on adherence to diabetes medications.

    Science.gov (United States)

    Zeng, Feng; Patel, Bimal V; Brunetti, Louis

    2013-04-01

    To investigate the impact of Part D coverage gap reform on diabetes medication adherence. Retrospective data analysis based on pharmacy claims data from a national pharmacy benefit manager. We used a difference-in-difference-indifference method to evaluate the impact of coverage gap reform on adherence to diabetes medications. Two cohorts (2010 and 2011) were constructed to represent the last year before Affordable Care Act (ACA) reform and the first year after reform, respectively. Each patient had 2 observations: 1 before and 1 after entering the coverage gap. Patients in each cohort were divided into groups based on type of gap coverage: no coverage, partial coverage (generics only), and full coverage. Following ACA reform, patients with no gap coverage and patients with partial gap coverage experienced substantial drops in copayments in the coverage gap in 2011. Their adherence to diabetes medications in the gap, measured by percentage of days covered, improved correspondingly (2.99 percentage points, 95% confidence interval [CI] 0.49-5.48, P = .019 for patients with no coverage; 6.46 percentage points, 95% CI 3.34-9.58, P gap in 2011. However, their adherence did not increase (-0.13 percentage point, P = .8011). In the first year of ACA coverage gap reform, copayments in the gap decreased substantially for all patients. Patients with no coverage and patients with partial coverage in the gap had better adherence in the gap in 2011.

  20. Electron identification and implications in SSC detector design

    International Nuclear Information System (INIS)

    Bensinger, J.; Wang, E.M.; Yamamoto, H.

    1990-05-01

    In the context of Heavy Higgs searches in the decay mode H → ZZ → 4e, electron identification issues and their implications on detector design are discussed (though many of the issues are valid for muon modes as well). The backgrounds considered seem manageable (a net rejection of 100 for combined electron ID and isolation cut is needed and seems fairly straightforward). A detector must have wide electron rapidity coverage η T > GeV; be hermetic (in the sense of minimizing regions where electrons can disappear through cracks, dead spaces, or poorly placed walls); and have high efficiency electron ID (∼ 0.90) since we are trying to be sensitive to a feeble signal and we need 4 electrons. The product of a number of fairly high acceptances based on optimistic estimates still yields in the end a net Higgs acceptance about 0.15 to 0.25 depending on how hermetic a detector is assumed. For M Higgs < 500 GeV, this may be tolerable; whereas, for higher Higgs masses, the situation is much less clear

  1. A Preshower Photon Multiplicity Detector for the ALICE Experiment

    CERN Document Server

    Aggarwal, M M; Baba, P V K S; Badyal, S K; Bharti, A; Bhasin, A; Bhati, A K; Bhatia, V S; Chattopadhyay, S; Dubey, A K; Dutta-Majumdar, M R; Mazumdar, K; Ganti, M S; Ghosh, P; Sen-Gupta, A; Gupta, V K; Mahapatra, D P; Mangotra, L K; Mohanty, B; Nayak, T K; Phatak, S C; Raniwala, R; Raniwala, S; Rao, N K; Sambyal, S S; Singaraju, R N; Sinha, B; Trivedi, M D; Viyogi, Y P

    1999-01-01

    A preshower Photon Multiplicity Detector (PMD) is proposed to be implemented in the ALICE experiment to study event shapes and isospin fluctuations. The PMD, to be mounted on the magnet door at 6m from the vertex, has fine granularity and full azimuthal coverage in the pseudo-rapidity region 1.8detector is based on a cellular honeycomb proportional chamber design for both the PMD and the CPV, and has a total of about 2 x 105 cels of 1 cm2 area. The honeycomb walls form a common cathode, operated at a high negative voltage. The signal is read out from the anode wires at ground potential using gassiplex electronics. The detector employs an inert gas mixture of Ar (70%) and CO2 (30%). Beam test results for a small prototype indicate that about 80% of the central volume of the detector has almost uniform efficiency (about 95%) for MIP detection. The average number of cells fired by a MIP is close to uni...

  2. Gamma-ray Full Spectrum Analysis for Environmental Radioactivity by HPGe Detector

    Science.gov (United States)

    Jeong, Meeyoung; Lee, Kyeong Beom; Kim, Kyeong Ja; Lee, Min-Kie; Han, Ju-Bong

    2014-12-01

    Odyssey, one of the NASA¡¯s Mars exploration program and SELENE (Kaguya), a Japanese lunar orbiting spacecraft have a payload of Gamma-Ray Spectrometer (GRS) for analyzing radioactive chemical elements of the atmosphere and the surface. In these days, gamma-ray spectroscopy with a High-Purity Germanium (HPGe) detector has been widely used for the activity measurements of natural radionuclides contained in the soil of the Earth. The energy spectra obtained by the HPGe detectors have been generally analyzed by means of the Window Analysis (WA) method. In this method, activity concentrations are determined by using the net counts of energy window around individual peaks. Meanwhile, an alternative method, the so-called Full Spectrum Analysis (FSA) method uses count numbers not only from full-absorption peaks but from the contributions of Compton scattering due to gamma-rays. Consequently, while it takes a substantial time to obtain a statistically significant result in the WA method, the FSA method requires a much shorter time to reach the same level of the statistical significance. This study shows the validation results of FSA method. We have compared the concentration of radioactivity of 40K, 232Th and 238U in the soil measured by the WA method and the FSA method, respectively. The gamma-ray spectrum of reference materials (RGU and RGTh, KCl) and soil samples were measured by the 120% HPGe detector with cosmic muon veto detector. According to the comparison result of activity concentrations between the FSA and the WA, we could conclude that FSA method is validated against the WA method. This study implies that the FSA method can be used in a harsh measurement environment, such as the gamma-ray measurement in the Moon, in which the level of statistical significance is usually required in a much shorter data acquisition time than the WA method.

  3. Gamma-ray Full Spectrum Analysis for Environmental Radioactivity by HPGe Detector

    Directory of Open Access Journals (Sweden)

    Meeyoung Jeong

    2014-12-01

    Full Text Available Odyssey, one of the NASA’s Mars exploration program and SELENE (Kaguya, a Japanese lunar orbiting spacecraft have a payload of Gamma-Ray Spectrometer (GRS for analyzing radioactive chemical elements of the atmosphere and the surface. In these days, gamma-ray spectroscopy with a High-Purity Germanium (HPGe detector has been widely used for the activity measurements of natural radionuclides contained in the soil of the Earth. The energy spectra obtained by the HPGe detectors have been generally analyzed by means of the Window Analysis (WA method. In this method, activity concentrations are determined by using the net counts of energy window around individual peaks. Meanwhile, an alternative method, the so-called Full Spectrum Analysis (FSA method uses count numbers not only from full-absorption peaks but from the contributions of Compton scattering due to gamma-rays. Consequently, while it takes a substantial time to obtain a statistically significant result in the WA method, the FSA method requires a much shorter time to reach the same level of the statistical significance. This study shows the validation results of FSA method. We have compared the concentration of radioactivity of 40K, 232Th and 238U in the soil measured by the WA method and the FSA method, respectively. The gamma-ray spectrum of reference materials (RGU and RGTh, KCl and soil samples were measured by the 120% HPGe detector with cosmic muon veto detector. According to the comparison result of activity concentrations between the FSA and the WA, we could conclude that FSA method is validated against the WA method. This study implies that the FSA method can be used in a harsh measurement environment, such as the gamma-ray measurement in the Moon, in which the level of statistical significance is usually required in a much shorter data acquisition time than the WA method.

  4. Improving differential die-away analysis via the use of neutron poisons in detectors

    International Nuclear Information System (INIS)

    Jordan, Kelly A.; Vujic, Jasmina; Phillips, Emmanuel; Gozani, Tsahi

    2007-01-01

    Differential Die-Away Analysis (DDAA) is an active interrogation technique to detect special nuclear material (SNM). In DDAA, a pulsed neutron generator produces pulses of neutrons that are directed into a cargo to be interrogated. As each pulse passes through the cargo, the neutrons are thermalized and absorbed. If SNM is present, the thermalized neutrons from the source will cause fissions that produce a new source of neutrons. The number of thermal neutrons decay exponentially with the diffusion decay time of the inspected medium, on the order of hundreds of μs. An external neutron detector which is designed to detect only epithermal neutrons, will measure only a single decaying exponential when there is no SNM present, and two exponentials when SNM is present. This paper shows that in many cases, a gain in detection sensitivity can be realized by introducing a thermal neutron poison (such as boron) into the detector. This poison will reduce the efficiency of the detector, but decrease its decay time. A decreased decay time will cause the separation between the detector and fission signal exponentials to occur at an earlier time. There is a balance between efficiency and time constant for a detector. The boron concentration to achieve the maximum sensitivity, and its magnitude, will be different for different detector designs

  5. Straw detector: 1 - Vacuum: 0

    CERN Multimedia

    Katarina Anthony

    2012-01-01

    The NA62 straw tracker is using pioneering CERN technology to measure charged particles from very rare kaon decays. For the first time, a large straw tracker with a 4.4 m2 coverage will be placed directly into an experiment’s vacuum tank, allowing physicists to measure the direction and momentum of charged particles with extreme precision. NA62 measurements using this technique will help physicists take a clear look at the kaon decay rate, which might be influenced by particles and processes that are not included in the Standard Model.   Straw ends are glued to an aluminium frame, a crucial step in the assembly of a module. The ends are then visually inspected before a leak test is performed.  “Although straw detectors have been around since the 1980s, what makes the NA62 straw trackers different is that they can work under vacuum,” explains Hans Danielsson from the PH-DT group leading the NA62 straw project. Straw detectors are basically small drift cha...

  6. Analysis of international intercomparisons results organized by Japan for integrating 222Rn-220Rn detectors

    International Nuclear Information System (INIS)

    Wu Yunyun; Cui Hongxing; Zhang Qingzhao; Shang Bing; Su Xu

    2012-01-01

    Objective: To guarantee the quality of measurements with the radon-thoron discriminative detectors of our laboratory. Methods: LD-P radon-thoron discriminative detector participated in the international intercomparison for integrating radon/thoron detectors organized by National Institute of Radiological Science (NIRS, Japan). Detectors were sent to NIRS for exposure. Radon intercomparison was conducted with radon chamber providing three levels of exposure: low, medium and high levels. Thoron intercomparison was carried out at thoron chamber, which also provided three levels of exposure: low, medium and high levels. Detectors were posted back to our laboratory for etching and analysis after exposure. Then the measured values were submitted to NIRS. Finally the reference values were informed of us. Results: The relative percent difference (RPD) between the measured value and the reference value for radon was -13.8%, -14.4% and -17.1% at low, medium and high levels respectively, and that of thoron were -14.4%, 8.9% and -3.2% at three levels respectively. Conclusions: Both radon and thoron measurement of our detectors rank as 'Category Ⅰ' in the 4th international intercomparisons for integrating radon/thoron detectors with the NIRS radon/thoron chambers. (authors)

  7. Radiation detectors laboratory

    International Nuclear Information System (INIS)

    Ramirez J, F.J.

    1996-01-01

    The National Institute for Nuclear Research has established a Radiation detector laboratory that has the possibility of providing to the consultants on the handling and applications of the nuclear radiation detectors. It has special equipment to repair the radiation detectors used in spectroscopy as the hyper pure Germanium for gamma radiation and the Lithium-silica for X-rays. There are different facilities in the laboratory that can become useful for other institutions that use radiation detectors. This laboratory was created to satisfy consultant services, training and repairing of the radiation detectors both in national and regional levels for Latin America. The laboratory has the following sections: Nuclear Electronic Instrumentation; where there are all kind of instruments for the measurement and characterization of detectors like multichannel analyzers of pulse height, personal computers, amplifiers and nuclear pulse preamplifiers, nuclear pulses generator, aleatories, computer programs for radiation spectra analysis, etc. High vacuum; there is a vacuum escape measurer, two high vacuum pumps to restore the vacuum of detectors, so the corresponding measurers and the necessary tools. Detectors cleaning; there is an anaerobic chamber for the detectors handling at inert atmosphere, a smoke extraction bell for cleaning with the detector solvents. Cryogenic; there are vessels and tools for handling liquid nitrogen which is used for cooling the detectors when they required it. (Author)

  8. DIRC-based PID for the EIC central detector

    Energy Technology Data Exchange (ETDEWEB)

    Dzhygadlo, Roman; Schwarz, Carsten; Schwiening, Jochen [GSI Helmholtzzentrum fuer Schwerionenforschung GmbH, Darmstadt (Germany); Peters, Klaus [GSI Helmholtzzentrum fuer Schwerionenforschung GmbH, Darmstadt (Germany); Goethe-Universitaet Frankfurt (Germany); Collaboration: DIRC at EIC RD-Collaboration

    2015-07-01

    One of the key requirements for the central detector of a future Electron-Ion Collider (EIC) is to provide radially compact Particle Identification (PID) (e/π,π/K,K/p) over a wide momentum range. It is expected that the PID system will need to include one or more Cherenkov counters to achieve this goal. With a radial size of only a few cm, a DIRC counter (Detector of Internally Reflected Cherenkov light) is potentially an attractive option. The DIRC rate at EIC R and D Collaboration was formed by groups in the United States and Germany in 2011 with funding from DOE to investigate ways to extend the momentum coverage of DIRC counters for the EIC detector by up to 50% beyond the current state of the art. Possible design improvements include a complex focusing system, multi-anode sensors with smaller pixels, a time-based reconstruction algorithm, and chromatic dispersion mitigation. Both Geant and ray-tracing simulations are used to optimize the design configuration of the DIRC counter in terms of the performance and the best integration with the EIC detector. We discuss the current status of the design studies and the possible improvements to the Cherenkov angle resolution and the photon yield.

  9. Semiconductor X-ray detectors

    CERN Document Server

    Lowe, Barrie Glyn

    2014-01-01

    Identifying and measuring the elemental x-rays released when materials are examined with particles (electrons, protons, alpha particles, etc.) or photons (x-rays and gamma rays) is still considered to be the primary analytical technique for routine and non-destructive materials analysis. The Lithium Drifted Silicon (Si(Li)) X-Ray Detector, with its good resolution and peak to background, pioneered this type of analysis on electron microscopes, x-ray fluorescence instruments, and radioactive source- and accelerator-based excitation systems. Although rapid progress in Silicon Drift Detectors (SDDs), Charge Coupled Devices (CCDs), and Compound Semiconductor Detectors, including renewed interest in alternative materials such as CdZnTe and diamond, has made the Si(Li) X-Ray Detector nearly obsolete, the device serves as a useful benchmark and still is used in special instances where its large, sensitive depth is essential. Semiconductor X-Ray Detectors focuses on the history and development of Si(Li) X-Ray Detect...

  10. Investigation of gamma-ray sensitivity of neutron detectors based on thin converter films

    Energy Technology Data Exchange (ETDEWEB)

    Khaplanov, A; Hall-Wilton, R [European Spallation Source, P.O Box 176, SE-22100 Lund (Sweden); Piscitelli, F; Buffet, J-C; Clergeau, J-F; Correa, J; Esch, P van; Ferraton, M; Guerard, B [Institute Laue Langevin, Rue Jules Horowitz, FR-38042 Grenoble (France)

    2013-10-15

    Currently, many detector technologies for thermal neutron detection are in development in order to lower the demand for the rare {sup 3}He gas. Gas detectors with solid thin film neutron converters readout by gas proportional counter method have been proposed as an appropriate choice for applications where large area coverage is necessary. In this paper, we investigate the probability for {gamma}-rays to generate a false count in a neutron measurement. Simulated results are compared to measurement with {sup 10}B thin film prototypes and a {sup 3}He detector. It is demonstrated that equal {gamma}-ray rejection to that of {sup 3}He tubes is achieved with the new technology. The arguments and results presented here are also applicable to gas detectors with converters other than solid {sup 10}B layers, such as {sup 6}Li layers and {sup 10}BF{sub 3} gas.

  11. On Connected Target k-Coverage in Heterogeneous Wireless Sensor Networks.

    Science.gov (United States)

    Yu, Jiguo; Chen, Ying; Ma, Liran; Huang, Baogui; Cheng, Xiuzhen

    2016-01-15

    Coverage and connectivity are two important performance evaluation indices for wireless sensor networks (WSNs). In this paper, we focus on the connected target k-coverage (CTC k) problem in heterogeneous wireless sensor networks (HWSNs). A centralized connected target k-coverage algorithm (CCTC k) and a distributed connected target k-coverage algorithm (DCTC k) are proposed so as to generate connected cover sets for energy-efficient connectivity and coverage maintenance. To be specific, our proposed algorithms aim at achieving minimum connected target k-coverage, where each target in the monitored region is covered by at least k active sensor nodes. In addition, these two algorithms strive to minimize the total number of active sensor nodes and guarantee that each sensor node is connected to a sink, such that the sensed data can be forwarded to the sink. Our theoretical analysis and simulation results show that our proposed algorithms outperform a state-of-art connected k-coverage protocol for HWSNs.

  12. Measurement and analysis of high energy radiation through activation detectors. Application in dosimetry

    International Nuclear Information System (INIS)

    Sklavenitis, L.

    1967-10-01

    This work is concerned with the possibility of measurement and analysis of radiation fluences within objects of small volume submitted to a high energy proton beam. The first part, consecrated to the establishment of a method of analysis, comprises a detailed study of the radiation nature and energy spectra as well as of the various dosimetry methods. In order to select a group of detectors, high energy nuclear reactions were systematically studied and for some of them cross sections were measured or calculated: for example the cross section of the reaction 11 B (p,n) 11 C between 150 and 3000 MeV and of the reaction 34 S (p,2pn) 32 P between 50 and 3000 MeV. The second part is relative to the application of the fore-mentioned analysis to radiation within a tissue equivalent phantom irradiated by 3 GeV protons. This analysis is sufficiently detailed to allow the reconstitution of the absorbed doses, the dose equivalent and, contingent on a better knowledge of the dose due to heavy particles, the quality factors. It allowed also to follow the evolution of the various dosimetric data as a function of the depth inside the phantom and to verify calculations already done by other researchers. The comparison of the measured doses and the corresponding detector activities revealed the possibility that some detectors could give directly the absorbed dose, or even the dose equivalent, by a simple activity measurement. (author) [fr

  13. Status of the ATLAS Pixel Detector at the LHC and its performance after three years of operation

    CERN Document Server

    Andreazza, A; The ATLAS collaboration

    2012-01-01

    The ATLAS Pixel Detector is the innermost detector of the ATLAS experiment at the Large Hadron Collider at CERN, providing high-resolution measurements of charged particle tracks in the high radiation environment close to the collision region. This capability is vital for the identification and measurement of proper decay times of long-lived particles such as b-hadrons, and thus vital for the ATLAS physics program. The detector provides hermetic coverage with three cylindrical layers and three layers of forward and backward pixel detectors. It consists of approximately 80 million pixels that are individually read out via chips bump-bonded to 1744 n-in-n silicon substrates. In this talk, results from the successful operation of the Pixel Detector at the LHC and its status after three years of operation will be presented, including monitoring, calibration procedures, timing optimization and detector performance. The detector performance is excellent: ~96 % of the pixels are operational, noise occupancy and hit ...

  14. How does the media portray drinking water security in Indigenous communities in Canada? An analysis of Canadian newspaper coverage from 2000-2015

    Directory of Open Access Journals (Sweden)

    Steven Lam

    2017-03-01

    Full Text Available Abstract Background Drinking water insecurity and related health outcomes often disproportionately impact Indigenous communities internationally. Understanding media coverage of these water-related issues can provide insight into the ways in which public perceptions are shaped, with potential implications for decision-making and action. This study aimed to examine the extent, range, and nature of newspaper coverage of drinking water security in Canadian Indigenous communities. Methods Using ProQuest database, we systematically searched for and screened newspaper articles published from 2000 to 2015 from Canadian newspapers: Windspeaker, Toronto Star, The Globe and Mail, and National Post. We conducted descriptive quantitative analysis and thematic qualitative analysis on relevant articles to characterize framing and trends in coverage. Results A total of 1382 articles were returned in the search, of which 256 articles were identified as relevant. There was limited coverage of water challenges for Canadian Indigenous communities, especially for Métis (5% and Inuit (3% communities. Most stories focused on government responses to water-related issues, and less often covered preventative measures such as source water protection. Overall, Indigenous peoples were quoted the most often. Double-standards of water quality between Indigenous and non-Indigenous communities, along with conflict and cooperation efforts between stakeholders were emphasized in many articles. Conclusion Limited media coverage could undermine public and stakeholder interest in addressing water-related issues faced by many Canadian Indigenous communities.

  15. Detector Mount Design for IGRINS

    Directory of Open Access Journals (Sweden)

    Jae Sok Oh

    2014-06-01

    Full Text Available The Immersion Grating Infrared Spectrometer (IGRINS is a near-infrared wide-band high-resolution spectrograph jointly developed by the Korea Astronomy and Space Science Institute and the University of Texas at Austin. IGRINS employs three HAWAII-2RG Focal Plane Array (H2RG FPA detectors. We present the design and fabrication of the detector mount for the H2RG detector. The detector mount consists of a detector housing, an ASIC housing, a Field Flattener Lens (FFL mount, and a support base frame. The detector and the ASIC housing should be kept at 65 K and the support base frame at 130 K. Therefore they are thermally isolated by the support made of GFRP material. The detector mount is designed so that it has features of fine adjusting the position of the detector surface in the optical axis and of fine adjusting yaw and pitch angles in order to utilize as an optical system alignment compensator. We optimized the structural stability and thermal characteristics of the mount design using computer-aided 3D modeling and finite element analysis. Based on the structural and thermal analysis, the designed detector mount meets an optical stability tolerance and system thermal requirements. Actual detector mount fabricated based on the design has been installed into the IGRINS cryostat and successfully passed a vacuum test and a cold test.

  16. Using New Fission Data with the Multi-detector Analysis System for Spent Nuclear Fuel

    Energy Technology Data Exchange (ETDEWEB)

    Cole, Jerald Donald

    1998-11-01

    New experiments using an array of high purity germanium detectors and fast liquid scintillation detectors has been performed to observe the radiation emitted from the induced fission of 235U with a beam of thermal neutrons. The experiment was performed at the Argonne National Laboratory Intense Pulsed Neutron Source. Preliminary observations of the data are presented. A nondestructive analysis system for the characterization of DOE spent nuclear fuel based on these new data is presented.

  17. Development of GAGG depth-of-interaction (DOI) block detectors based on pulse shape analysis

    International Nuclear Information System (INIS)

    Yamamoto, Seiichi; Kobayashi, Takahiro; Yeol Yeom, Jung; Morishita, Yuki; Sato, Hiroki; Endo, Takanori; Usuki, Yoshiyuki; Kamada, Kei; Yoshikawa, Akira

    2014-01-01

    A depth-of-interaction (DOI) detector is required for developing a high resolution and high sensitivity PET system. Ce-doped Gd 3 Al 2 Ga 3 O 12 (GAGG fast: GAGG-F) is a promising scintillator for PET applications with high light output, no natural radioisotope and suitable light emission wavelength for semiconductor based photodetectors. However, no DOI detector based on pulse shape analysis with GAGG-F has been developed to date, due to the lack of appropriate scintillators of pairing. Recently a new variation of this scintillator with different Al/Ga ratios—Ce-doped Gd 3 Al 2.6 Ga 2.4 O 12 (GAGG slow: GAGG-S), which has slower decay time was developed. The combination of GAGG-F and GAGG-S may allow us to realize high resolution DOI detectors based on pulse shape analysis. We developed and tested two GAGG phoswich DOI block detectors comprised of pixelated GAGG-F and GAGG-S scintillation crystals. One phoswich block detector comprised of 2×2×5 mm pixel that were assembled into a 5×5 matrix. The DOI block was optically coupled to a silicon photomultiplier (Si-PM) array (Hamamatsu MPPC S11064-050P) with a 2-mm thick light guide. The other phoswich block detector comprised of 0.5×0.5×5 mm (GAGG-F) and 0.5×0.5×6 mm 3 (GAGG-S) pixels that were assembled into a 20×20 matrix. The DOI block was also optically coupled to the same Si-PM array with a 2-mm thick light guide. In the block detector of 2-mm crystal pixels (5×5 matrix), the 2-dimensional histogram revealed excellent separation with an average energy resolution of 14.1% for 662-keV gamma photons. The pulse shape spectrum displayed good separation with a peak-to-valley ratio of 8.7. In the block detector that used 0.5-mm crystal pixels (20×20 matrix), the 2-dimensional histogram also showed good separation with energy resolution of 27.5% for the 662-keV gamma photons. The pulse shape spectrum displayed good separation with a peak-to-valley ratio of 6.5. These results indicate that phoswich DOI

  18. Smile detectors correlation

    Science.gov (United States)

    Yuksel, Kivanc; Chang, Xin; Skarbek, Władysław

    2017-08-01

    The novel smile recognition algorithm is presented based on extraction of 68 facial salient points (fp68) using the ensemble of regression trees. The smile detector exploits the Support Vector Machine linear model. It is trained with few hundreds exemplar images by SVM algorithm working in 136 dimensional space. It is shown by the strict statistical data analysis that such geometric detector strongly depends on the geometry of mouth opening area, measured by triangulation of outer lip contour. To this goal two Bayesian detectors were developed and compared with SVM detector. The first uses the mouth area in 2D image, while the second refers to the mouth area in 3D animated face model. The 3D modeling is based on Candide-3 model and it is performed in real time along with three smile detectors and statistics estimators. The mouth area/Bayesian detectors exhibit high correlation with fp68/SVM detector in a range [0:8; 1:0], depending mainly on light conditions and individual features with advantage of 3D technique, especially in hard light conditions.

  19. Snapshot analysis for rhodium fixed incore detector using BEACON methodology

    International Nuclear Information System (INIS)

    Cha, Kyoon Ho; Choi, Yu Sun; Lee, Eun Ki; Park, Moon Ghu; Morita, Toshio; Heibel, Michael D.

    2004-01-01

    The purpose of this report is to process the rhodium detector data of the Yonggwang nuclear unit 4 cycle 5 core for the measured power distribution by using the BEACON methodology. Rhodium snapshots of the YGN 4 cycle 5 have been analyzed by both BEACON/SPINOVA and CECOR to compare the results of both codes. By analyzing a large number of snapshots obtained during normal plant operation. Reviewing the results of this analysis, the BEACON/SPNOVA can be used for the snapshot analysis of Korean Standard Nuclear Power (KSNP) plants

  20. Progress Toward Universal Health Coverage: A Comparative Analysis in 5 South Asian Countries.

    Science.gov (United States)

    Rahman, Md Mizanur; Karan, Anup; Rahman, Md Shafiur; Parsons, Alexander; Abe, Sarah Krull; Bilano, Ver; Awan, Rabia; Gilmour, Stuart; Shibuya, Kenji

    2017-09-01

    Achieving universal health coverage is one of the key targets in the newly adopted Sustainable Development Goals of the United Nations. To investigate progress toward universal health coverage in 5 South Asian countries and assess inequalities in health services and financial risk protection indicators. In a population-based study, nationally representative household (335 373 households) survey data from Afghanistan (2014 and 2015), Bangladesh (2010 and 2014), India (2012 and 2014), Nepal (2014 and 2015), and Pakistan (2014) were used to calculate relative indices of health coverage, financial risk protection, and inequality in coverage among wealth quintiles. The study was conducted from June 2012 to February 2016. Three dimensions of universal health coverage were assessed: access to basic services, financial risk protection, and equity. Composite and indicator-specific coverage rates, stratified by wealth quintiles, were then estimated. Slope and relative index of inequality were used to assess inequalities in service and financial indicators. Access to basic care varied substantially across all South Asian countries, with mean rates of overall prevention coverage and treatment coverage of 53.0% (95% CI, 42.2%-63.6%) and 51.2% (95% CI, 45.2%-57.1%) in Afghanistan, 76.5% (95% CI, 61.0%-89.0%) and 44.8% (95% CI, 37.1%-52.5%) in Bangladesh, 74.2% (95% CI, 57.0%-88.1%) and 83.5% (95% CI, 54.4%-99.1%) in India, 76.8% (95% CI, 66.5%-85.7%) and 57.8% (95% CI, 50.1%-65.4%) in Nepal, and 69.8% (95% CI, 58.3%-80.2%) and 50.4% (95% CI, 37.1%-63.6%) in Pakistan. Financial risk protection was generally low, with 15.3% (95% CI, 14.7%-16.0%) of respondents in Afghanistan, 15.8% (95% CI, 14.9%-16.8%) in Bangladesh, 17.9% (95% CI, 17.7%-18.2%) in India, 11.8% (95% CI, 11.8%-11.9%) in Nepal, and 4.4% (95% CI, 4.0%-4.9%) in Pakistan reporting incurred catastrophic payments due to health care costs. Access to at least 4 antenatal care visits, institutional delivery, and presence

  1. A comparative and combined study of EMIS and GPR detectors by the use of Independent Component Analysis

    DEFF Research Database (Denmark)

    Morgenstjerne, Axel; Karlsen, Brian; Larsen, Jan

    2005-01-01

    Independent Component Analysis (ICA) is applied to classify unexploded ordnance (UXO) on laboratory UXO test-field data, acquired by stand-off detection. The data are acquired by an Electromagnetic Induction Spectroscopy (EMIS) metal detector and a ground penetrating radar (GPR) detector. The metal...

  2. An analysis of the control hierarchy modelling of the CMS detector control system

    Energy Technology Data Exchange (ETDEWEB)

    Hwong, Yi-Ling; et al.

    2011-01-01

    The supervisory level of the Detector Control System (DCS) of the CMS experiment is implemented using Finite State Machines (FSM), which model the behaviours and control the operations of all the sub-detectors and support services. The FSM tree of the whole CMS experiment consists of more than 30.000 nodes. An analysis of a system of such size is a complex task but is a crucial step towards the improvement of the overall performance of the FSM system. This paper presents the analysis of the CMS FSM system using the micro Common Representation Language 2 (mcrl2) methodology. Individual mCRL2 models are obtained for the FSM systems of the CMS sub-detectors using the ASF+SDF automated translation tool. Different mCRL2 operations are applied to the mCRL2 models. A mCRL2 simulation tool is used to closer examine the system. Visualization of a system based on the exploration of its state space is enabled with a mCRL2 tool. Requirements such as command and state propagation are expressed using modal mu-calculus and checked using a model checking algorithm. For checking local requirements such as endless loop freedom, the Bounded Model Checking technique is applied. This paper discusses these analysis techniques and presents the results of their application on the CMS FSM system.

  3. Online gas analysis and diagnosis for RPC detectors in the ATLAS experiment

    International Nuclear Information System (INIS)

    De Asmundis, Riccardo

    2007-01-01

    Resistive Plate Counters (RPC) detectors need a very strict control of gas parameters: motivations for this statement come from both the request of stability in the detector working point, and chemical consideration concerning potentially aggressive materials generated during the ionization processes into the sensitive gap; the latter point can be relevant because of a possible damage to the internal surface of the detector that has to be avoided in order to ensure an high detection efficiency of the RPC during their ten years or more of operation in ATLAS. In order to understand these aspects, detailed studies on gas behavior have been carried on at the GIF-X5 at CERN (2002-2005), based on Gas Chromatographic and spectroscopy techniques. Main results of these analysis are presented here, together with the design of the online analyzer to be installed on ATLAS conceived to keep control of gas quality and to trigger maintenance interventions on the gas system, in particular on the purification subsystem

  4. Analysis of the effects of pair production for the suppressed clover detector

    International Nuclear Information System (INIS)

    Kshetri, R.

    2014-01-01

    Full energy peak, single escape peak and double escape peak areas have been extracted for an escape suppressed clover detector. Results have been obtained for the single crystal and addback modes of operation as well as the active and passive suppression cases at several gamma energies. We have compared the ratio of single escape peak areas in addback mode with that of single crystal mode to study if the single escape peak gains or loses counts due to addback mode. Detailed analysis has been performed for quantifying the advantages of using addback mode and active suppression. Comparison is made for different types of clover detectors with different volumes

  5. Analysis of photogenerated random telegraph signal in single electron detector (photo-SET).

    Science.gov (United States)

    Troudi, M; Sghaier, Na; Kalboussi, A; Souifi, A

    2010-01-04

    In this paper, we analyzed slow single traps, situated inside the tunnel oxide of small area single electron photo-detector (photo-SET or nanopixel). The relationship between excitation signal (photons) and random-telegraph-signal (RTS) was evidenced. We demonstrated that photoinduced RTS observed on a photo-detector is due to the interaction between single photogenerated charges that tunnel from dot to dot and current path. Based on RTS analysis for various temperatures, gate bias and optical power we determined the characteristics of these single photogenerated traps: the energy position within the silicon bandgap, capture cross section and the position within the Si/SiO(x = 1.5) interfaces.

  6. Using New Fission Data with the Multi-detector Analysis System for Spent Nuclear Fuel

    Energy Technology Data Exchange (ETDEWEB)

    A. V. Ramayya; A.V. Daniel (Joint Institute for Nuclear Research); C. J. Beyer (Vanderbilt Univ.); E. L. Reber; G. M. Ter-Akopian; G.S. Popeko; J. D. Cole; J. H. Hamilton; J. K. Jewell (INEEL); M. W. Drigert; R. Aryaeinejad; Ts.Yu. Oganessian

    1998-11-01

    New experiments using an array of high purity germanium detectors and fast liquid scintillation detectors has been performed to observe the radiation emitted from the induced fission of 235U with a beam of thermal neutrons. The experiment was performed at the Argonne National Laboratory Intense Pulsed Neutron Source. Preliminary observations of the data are presented. A nondestructive analysis system for the characterization of DOE spent nuclear fuel based on these new data is presented.

  7. Assessing Requirements Quality through Requirements Coverage

    Science.gov (United States)

    Rajan, Ajitha; Heimdahl, Mats; Woodham, Kurt

    2008-01-01

    In model-based development, the development effort is centered around a formal description of the proposed software system the model. This model is derived from some high-level requirements describing the expected behavior of the software. For validation and verification purposes, this model can then be subjected to various types of analysis, for example, completeness and consistency analysis [6], model checking [3], theorem proving [1], and test-case generation [4, 7]. This development paradigm is making rapid inroads in certain industries, e.g., automotive, avionics, space applications, and medical technology. This shift towards model-based development naturally leads to changes in the verification and validation (V&V) process. The model validation problem determining that the model accurately captures the customer's high-level requirements has received little attention and the sufficiency of the validation activities has been largely determined through ad-hoc methods. Since the model serves as the central artifact, its correctness with respect to the users needs is absolutely crucial. In our investigation, we attempt to answer the following two questions with respect to validation (1) Are the requirements sufficiently defined for the system? and (2) How well does the model implement the behaviors specified by the requirements? The second question can be addressed using formal verification. Nevertheless, the size and complexity of many industrial systems make formal verification infeasible even if we have a formal model and formalized requirements. Thus, presently, there is no objective way of answering these two questions. To this end, we propose an approach based on testing that, when given a set of formal requirements, explores the relationship between requirements-based structural test-adequacy coverage and model-based structural test-adequacy coverage. The proposed technique uses requirements coverage metrics defined in [9] on formal high-level software

  8. Women's Health Insurance Coverage

    Science.gov (United States)

    ... Women's Health Policy Women’s Health Insurance Coverage Women’s Health Insurance Coverage Published: Oct 31, 2017 Facebook Twitter LinkedIn ... that many women continue to face. Sources of Health Insurance Coverage Employer-Sponsored Insurance: Approximately 57.9 million ...

  9. Method of quantitative analysis of fluorine in environmental samples using a pure-Ge detector

    International Nuclear Information System (INIS)

    Sera, K.; Terasaki, K.; Saitoh, Y.; Itoh, J.; Futatsugawa, S.; Murao, S.; Sakurai, S.

    2004-01-01

    We recently developed and reported a three-detector measuring system making use of a pure-Ge detector combined with two Si(Li) detectors. The efficiency curve of the pure-Ge detector was determined as relative efficiencies to those of the existing Si(Li) detectors and accuracy of it was confirmed by analyzing a few samples whose elemental concentrations were known. It was found that detection of fluorine becomes possible by analyzing prompt γ-rays and the detection limit was found to be less than 0.1 ppm for water samples. In this work, a method of quantitative analysis of fluorine has been established in order to investigate environmental contamination by fluorine. This method is based on the fact that both characteristic x-rays from many elements and 110 keV prompt γ-rays from fluorine can be detected in the same spectrum. The present method is applied to analyses of a few environmental samples such as tealeaves, feed for domestic animals and human bone. The results are consistent with those obtained by other methods and it is found that the present method is quite useful and convenient for investigation studies on regional pollution by fluorine. (author)

  10. Single-Isocenter Multiple-Target Stereotactic Radiosurgery: Risk of Compromised Coverage

    International Nuclear Information System (INIS)

    Roper, Justin; Chanyavanich, Vorakarn; Betzel, Gregory; Switchenko, Jeffrey; Dhabaan, Anees

    2015-01-01

    Purpose: To determine the dosimetric effects of rotational errors on target coverage using volumetric modulated arc therapy (VMAT) for multitarget stereotactic radiosurgery (SRS). Methods and Materials: This retrospective study included 50 SRS cases, each with 2 intracranial planning target volumes (PTVs). Both PTVs were planned for simultaneous treatment to 21 Gy using a single-isocenter, noncoplanar VMAT SRS technique. Rotational errors of 0.5°, 1.0°, and 2.0° were simulated about all axes. The dose to 95% of the PTV (D95) and the volume covered by 95% of the prescribed dose (V95) were evaluated using multivariate analysis to determine how PTV coverage was related to PTV volume, PTV separation, and rotational error. Results: At 0.5° rotational error, D95 values and V95 coverage rates were ≥95% in all cases. For rotational errors of 1.0°, 7% of targets had D95 and V95 values 95% for only 63% of the targets. Multivariate analysis showed that PTV volume and distance to isocenter were strong predictors of target coverage. Conclusions: The effects of rotational errors on target coverage were studied across a broad range of SRS cases. In general, the risk of compromised coverage increased with decreasing target volume, increasing rotational error and increasing distance between targets. Multivariate regression models from this study may be used to quantify the dosimetric effects of rotational errors on target coverage given patient-specific input parameters of PTV volume and distance to isocenter.

  11. Coincidence measurements in α/β/γ spectrometry with phoswich detectors using digital pulse shape discrimination analysis

    International Nuclear Information System (INIS)

    Celis, B. de; Fuente, R. de la; Williart, A.; Celis Alonso, B. de

    2007-01-01

    A novel system has been developed for the detection of low radioactivity levels using coincidence techniques. The device combines a phoswich detector for α/β/γ ray recognition with a fast digital card for electronic pulse analysis. The detector is able to discriminate different types of radiation in a mixed α/β/γ field and can be used in a coincidence mode by identifying the composite signal produced by the simultaneous detection of β particles in a plastic scintillator and γ rays in an NaI(Tl) scintillator. Use of a coincidence technique with phoswich detectors was proposed recently to verify the Nuclear Test Ban Treaty, which made it necessary to monitor the low levels of xenon radioisotopes produced by underground nuclear explosions. Previous studies have shown that combining CaF 2 (Eu) for β ray detection and NaI(Tl) for γ ray detection makes it difficult to identify the coincidence signals because of the similar fluorescence decay times of the two scintillators. With the device proposed here, it is possible to identify the coincidence events owing to the short fluorescence decay time of the plastic scintillator. The sensitivity of the detector may be improved by employing liquid scintillators, which allow low radioactivity levels from actinides to be measured when present in environmental samples. The device developed is simpler to use than conventional coincidence equipment because it uses a single detector and electronic circuit, and it offers fast and precise analysis of the coincidence signals by employing digital pulse shape analysis

  12. Drift chamber detectors

    International Nuclear Information System (INIS)

    Duran, I.; Martinez Laso, L.

    1989-01-01

    A review of High Energy Physics detectors based on drift chambers is presented. The ionization, drift diffusion, multiplication and detection principles are described. Most common drift media are analysied, and a classification of the detectors according to its geometry is done. Finally the standard read-out methods are displayed and the limits of the spatial resolution are discussed. (Author)

  13. The use of decision analysis to evaluate the economic effects of heat mount detectors in two dairy herds.

    Science.gov (United States)

    Williamson, N B

    1975-03-01

    This paper reports a decrease in the interval from calving to conception in two commercial dairy herds, associated with the use of KaMaR Heat Mount Detectors. An economic analysis of the results uses a neoclassical decision theory approach to demonstrate that the use of heat mount detectors is likely to be profitable, with an expected net return of $154.18 per 100 calvings. The analysis demonstrates the suitability of a decision-theoretic approach to the analysis of applied research, and illustrates some of the weaknesses of "Classical" statistical analysis in such circumstances.

  14. LArSoft: toolkit for simulation, reconstruction and analysis of liquid argon TPC neutrino detectors

    Science.gov (United States)

    Snider, E. L.; Petrillo, G.

    2017-10-01

    LArSoft is a set of detector-independent software tools for the simulation, reconstruction and analysis of data from liquid argon (LAr) neutrino experiments The common features of LAr time projection chambers (TPCs) enable sharing of algorithm code across detectors of very different size and configuration. LArSoft is currently used in production simulation and reconstruction by the ArgoNeuT, DUNE, LArlAT, MicroBooNE, and SBND experiments. The software suite offers a wide selection of algorithms and utilities, including those for associated photo-detectors and the handling of auxiliary detectors outside the TPCs. Available algorithms cover the full range of simulation and reconstruction, from raw waveforms to high-level reconstructed objects, event topologies and classification. The common code within LArSoft is contributed by adopting experiments, which also provide detector-specific geometry descriptions, and code for the treatment of electronic signals. LArSoft is also a collaboration of experiments, Fermilab and associated software projects which cooperate in setting requirements, priorities, and schedules. In this talk, we outline the general architecture of the software and the interaction with external libraries and detector-specific code. We also describe the dynamics of LArSoft software development between the contributing experiments, the projects supporting the software infrastructure LArSoft relies on, and the core LArSoft support project.

  15. Coverage and Capacity Analysis of Sigfox, LoRa, GPRS, and NB-IoT

    DEFF Research Database (Denmark)

    Vejlgaard, Benny; Lauridsen, Mads; Nguyen, Huan Cong

    2017-01-01

    is challenged for indoor coverage. Furthermore, the study analyzes the capacity of the four technologies assuming a traffic growth from 1 to 10 IoT device per user. The conclusion is that the 95 %-tile uplink failure rate for outdoor users is below 5 % for all technologies. For indoor users only NB-IoT provides......In this paper the coverage and capacity of SigFox, LoRa, GPRS, and NB-IoT is compared using a real site deployment covering 8000 km2 in Northern Denmark. Using the existing Telenor cellular site grid it is shown that the four technologies have more than 99 % outdoor coverage, while GPRS...

  16. Terrorism and nuclear damage coverage

    International Nuclear Information System (INIS)

    Horbach, N. L. J. T.; Brown, O. F.; Vanden Borre, T.

    2004-01-01

    This paper deals with nuclear terrorism and the manner in which nuclear operators can insure themselves against it, based on the international nuclear liability conventions. It concludes that terrorism is currently not covered under the treaty exoneration provisions on 'war-like events' based on an analysis of the concept on 'terrorism' and travaux preparatoires. Consequently, operators remain liable for nuclear damage resulting from terrorist acts, for which mandatory insurance is applicable. Since nuclear insurance industry looks at excluding such insurance coverage from their policies in the near future, this article aims to suggest alternative means for insurance, in order to ensure adequate compensation for innocent victims. The September 11, 2001 attacks at the World Trade Center in New York City and the Pentagon in Washington, DC resulted in the largest loss in the history of insurance, inevitably leading to concerns about nuclear damage coverage, should future such assaults target a nuclear power plant or other nuclear installation. Since the attacks, some insurers have signalled their intentions to exclude coverage for terrorism from their nuclear liability and property insurance policies. Other insurers are maintaining coverage for terrorism, but are establishing aggregate limits or sublimits and are increasing premiums. Additional changes by insurers are likely to occur. Highlighted by the September 11th events, and most recently by those in Madrid on 11 March 2004, are questions about how to define acts of terrorism and the extent to which such are covered under the international nuclear liability conventions and various domestic nuclear liability laws. Of particular concern to insurers is the possibility of coordinated simultaneous attacks on multiple nuclear facilities. This paper provides a survey of the issues, and recommendations for future clarifications and coverage options.(author)

  17. A content analysis of smokeless tobacco coverage in U.S. newspapers and news wires.

    Science.gov (United States)

    Wackowski, Olivia A; Lewis, M Jane; Delnevo, Cristine D; Ling, Pamela M

    2013-07-01

    Research attention on smokeless tobacco (SLT) has focused on SLT use, health risks, harm-reduction potential, and risk perceptions, but few studies have examined mediated communications about SLT. This study aims to contribute to the literature by providing the first description of SLT coverage in the news, an important communication channel given its ability to educate and shape public opinion about tobacco issues. A content analysis was conducted on SLT-related news and opinion articles between 2006 and 2010 from top circulating national and state newspapers and select news wires. Articles were coded for the main SLT topic, SLT risk references, and slant of opinion articles. SLT was discussed in news/feature articles (n = 677) in terms of business (28%), new products, product regulation and harm reduction (19%), prevention/cessation (11.4%), taxation (10.2%), profiles/trends in use (9%), bans (8.1%), and tobacco industry promotional activities (4.9%). Health risk references (i.e., addictiveness, carcinogenicity, and specific health effects including oral cancer) were found in 40% of articles, though frequency differed by article topic. Although the majority of opinion articles (n = 176) conveyed an anti-SLT slant (64%), 25.6% were pro-SLT. SLT topics of both national and local importance are covered in the news. Public health professionals can participate in SLT coverage by sending in press releases about new study findings, events, or resources and by submitting opinion pieces to share views or respond to previous coverage. Research on SLT news should continue given its potential to shape the public's SLT knowledge and opinions.

  18. [Vaccination coverage in young, middle age and elderly adults in Mexico].

    Science.gov (United States)

    Cruz-Hervert, Luis Pablo; Ferreira-Guerrero, Elizabeth; Díaz-Ortega, José Luis; Trejo-Valdivia, Belem; Téllez-Rojo, Martha María; Mongua-Rodríguez, Norma; Hernández-Serrato, María I; Montoya-Rodríguez, Airain Alejandra; García-García, Lourdes

    2013-01-01

    To estimate vaccination coverage in adults 20 years of age and older. Analysis of data obtained from the National Health and Nutrition Survey 2012. Among adults 20-59 years old coverage with complete scheme, measles and rubella (MR) and tetanus toxoid and diphtheria toxoid (Td) was 44.7,49. and 67.3%, respectively. Coverage and percentage of vaccination were significantly higher among women than men. Among women 20-49 years coverages with complete scheme, MR and Td were 48.3, 53.2 and 69.8%, respectively. Among adults 60-64 years old, coverage with complete scheme, Td and influenza vaccine were 46.5, 66.2 and 56.0%, respectively. Among adults >65 years coverages for complete scheme, Td, influenza vaccine and pneumococcal vaccine were 44.0, 69.0, 63.3 and 62.0%, respectively. Vaccination coverage among adult population as obtained from vaccination card or self-report is below optimal values although data may be underestimated. Recommendations for improvements are proposed.

  19. Insurance Coverage for Rehabilitation Therapies and Association with Social Participation Outcomes among Low-Income Children.

    Science.gov (United States)

    Mirza, Mansha; Kim, Yoonsang

    2016-01-01

    (1) To profile children's health insurance coverage rates for specific rehabilitation therapies; (2) to determine whether coverage for rehabilitation therapies is associated with social participation outcomes after adjusting for child and household characteristics; (3) to assess whether rehabilitation insurance differentially affects social participation of children with and without disabilities. We conducted a cross-sectional analysis of secondary survey data on 756 children (ages 3-17) from 370 households living in low-income neighborhoods in a Midwestern U.S. city. Multivariate mixed effects logistic regression models were estimated. Significantly higher proportions of children with disabilities had coverage for physical therapy, occupational therapy, and speech and language pathology, yet gaps in coverage were noted. Multivariate analysis indicated that rehabilitation insurance coverage was significantly associated with social participation (OR = 1.67, 95% CI: 1.013-2.75). This trend was sustained in subgroup analysis. Findings support the need for comprehensive coverage of all essential services under children's health insurance programs.

  20. Bariatric Surgery Coverage: a Comprehensive Budget Impact Analysis from a Payer Perspective.

    Science.gov (United States)

    Palli, Swetha R; Rizzo, John A; Heidrich, Natalie

    2018-06-01

    The objective of this study was to estimate a payer's budget impact of bariatric surgery coverage under (1) unrestricted, (2) budget-restricted ($500,000/year), and (3) quantity-restricted (100/year) medical benefit plan scenarios versus non-coverage in general and type 2 diabetes mellitus (T2DM) populations over a 10-year period. Using recently published literature and health technology assessment reports, the model evaluated a hypothetical payer population of 100,000 members under current real-world trends: BMI-defined obesity groups (31.3% normal/underweight, 33% overweight, 20.4% obese, 9% severely obese and 6.3% morbidly obese), T2DM prevalence (6.7-27.5%; 100% for the T2DM model), surgery type (LAGB, BPD/DS, VSG, and RYGB), and differential outcomes (T2DM resolution, costs, and reoperation and complications rates). Assuming a surgery election rate of 1.42% among eligible candidates with a 3% discount rate and 10% annual surgery turnover rate, the model calculated the incremental cost per-member-per-month (PMPM) by estimating the difference in total non-T2DM and T2DM-related expected costs and savings. One-way (± 25%) sensitivity analysis was performed. The impact of covering bariatric surgery under multiple scenarios for a general (or T2DM) population ranged from an additional $0.3 to $3.6 (T2DM: $0.3 to $10.5) PMPM in year 1. Incremental costs diminished over time, breaking even between years 5 and 9 (T2DM: 5-6), and by year 10, cost savings were estimated to be between $1.5 and $4.8 (T2DM: $1.2 and $31.8). Providing bariatric surgery coverage may have a modest short-term budget impact increase but would lead to long-term net cost savings in a general population model. The cost savings were much more pronounced in the T2DM model.

  1. The status of BAT detector

    Science.gov (United States)

    Lien, Amy; Markwardt, Craig B.; Krimm, Hans Albert; Barthelmy, Scott D.; Cenko, Bradley

    2018-01-01

    We will present the current status of the Swift/BAT detector. In particular, we will report the updated detector gain calibration, the number of enable detectors, and the global bad time intervals with potential calibration issues. We will also summarize the results of the yearly BAT calibration using the Crab nebula. Finally, we will discuss the effects on the BAT survey, such as the sensitivity, localization, and spectral analysis, due to the changes in detector status.

  2. Application of Gas Chromatographic analysis to RPC detectors in the ATLAS experiment at CERN-LHC

    CERN Document Server

    De Asmundis, R

    2007-01-01

    Starting from 2007 a large number (1200) Resistive Plate Chambers (RPC) detectors will be used as muon trigger detectors in the ATLAS Experiment at CERN-LHC accelerator. RPC are gaseous detector in which the quality and the stability of the gas mixture as well as the design of the gas supplying system, play a fundamental role in their functioning. RPC are foreseen to work more than ten years in the high radiation environment of ATLAS and the gas mixture acts really as a "lifeguard" for the detectors. For this reason a great attention has been devoted to the gas studies in order to optimize RPC performance, robustness and reliability in a high radiation environment. In this paper we describe the work done to decide how to supply and control in an optimal way the gas to the detectors, in order to ensure their best performance for a long time. The activity, based on Gas Chromatographic (GC) analysis, has been carried on a sample of final RPC working in radiation conditions much more intense than those foreseen f...

  3. Individual health insurance within the family : can subsidies promote family coverage?

    OpenAIRE

    Kanika Kapur; M. Susan Marquis; José J. Escarce

    2007-01-01

    This paper examines the role of price in health insurance coverage decisions within the family to guide policy in promoting whole family coverage. We analyze the factors that affect individual health insurance coverage among families, and explore family decisions about whom to cover and whom to leave uninsured. The analysis uses household data from California combined with abstracted individual health plan benefit and premium data. We find that premium subsidies for individual insurance would...

  4. A large, high performance, curved 2D position-sensitive neutron detector

    CERN Document Server

    Fried, J W; Mahler, G J; Makowiecki, D S; Mead, J A; Radeka, V; Schaknowski, N A; Smith, G C; Yu, B

    2002-01-01

    A new position-sensitive neutron detector has been designed and constructed for a protein crystallography station at LANL's pulsed neutron source. This station will be one of the most advanced instruments at a major neutron user facility for protein crystallography, fiber and membrane diffraction. The detector, based on neutron absorption in sup 3 He, has a large sensitive area of 3000 cm sup 2 , angular coverage of 120 deg. , timing resolution of 1 mu s, rate capability in excess of 10 sup 6 s sup - sup 1 , position resolution of about 1.5 mm FWHM, and efficiency >50% for neutrons of interest in the range 1-10 A. Features that are key to these remarkable specifications are the utilization of eight independently operating segments within a single gas volume, fabrication of the detector vessel and internal segments with a radius of curvature of about 70 cm, optimized position readout based on charge division and signal shaping with gated baseline restoration, and engineering design with high-strength aluminum ...

  5. A stationary computed tomography system with cylindrically distributed sources and detectors.

    Science.gov (United States)

    Chen, Yi; Xi, Yan; Zhao, Jun

    2014-01-01

    The temporal resolution of current computed tomography (CT) systems is limited by the rotation speed of their gantries. A helical interlaced source detector array (HISDA) CT, which is a stationary CT system with distributed X-ray sources and detectors, is presented in this paper to overcome the aforementioned limitation and achieve high temporal resolution. Projection data can be obtained from different angles in a short time and do not require source, detector, or object motion. Axial coverage speed is increased further by employing a parallel scan scheme. Interpolation is employed to approximate the missing data in the gaps, and then a Katsevich-type reconstruction algorithm is applied to enable an approximate reconstruction. The proposed algorithm suppressed the cone beam and gap-induced artifacts in HISDA CT. The results also suggest that gap-induced artifacts can be reduced by employing a large helical pitch for a fixed gap height. HISDA CT is a promising 3D dynamic imaging architecture given its good temporal resolution and stationary advantage.

  6. Inequity between male and female coverage in state infertility laws.

    Science.gov (United States)

    Dupree, James M; Dickey, Ryan M; Lipshultz, Larry I

    2016-06-01

    To analyze state insurance laws mandating coverage for male factor infertility and identify possible inequities between male and female coverage in state insurance laws. We identified states with laws or codes related to infertility insurance coverage using the National Conference of States Legislatures' and the National Infertility Association's websites. We performed a primary, systematic analysis of the laws or codes to specifically identify coverage for male factor infertility services. Not applicable. Not applicable. Not applicable. The presence or absence of language in state insurance laws mandating coverage for male factor infertility care. There are 15 states with laws mandating insurance coverage for female factor infertility. Only eight of those states (California, Connecticut, Massachusetts, Montana, New Jersey, New York, Ohio, and West Virginia) have mandates for male factor infertility evaluation or treatment. Insurance coverage for male factor infertility is most specific in Massachusetts, New Jersey, and New York, yet significant differences exist in the male factor policies in all eight states. Three states (Massachusetts, New Jersey, and New York) exempt coverage for vasectomy reversal. Despite national recommendations that male and female partners begin infertility evaluations together, only 8 of 15 states with laws mandating infertility coverage include coverage for the male partner. Excluding men from infertility coverage places an undue burden on female partners and risks missing opportunities to diagnose serious male health conditions, correct reversible causes of infertility, and provide cost-effective treatments that can downgrade the intensity of intervention required to achieve a pregnancy. Copyright © 2016 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.

  7. X-ray radiometric analysis of lead and zinc concentrates using germanium radiation detector

    International Nuclear Information System (INIS)

    Vajgachev, A.A.; Mamysh, V.A.; Mil'chakov, V.I.; Shchekin, K.I.; Berezkin, V.V.

    1975-01-01

    The results of determination of lead, zinc and iron in lead and zinc concentrates by the X-ray-radiometric method with the use of germanium semiconductor detector are presented. In the experiments the 57 Co source and tritium-zirconium target were used. The activity of 57 Co was 2 mc. The area of the germanium detector employed was 5g mm 2 , its thickness - 2.3 mm. In lead concentrates zinc and iron were determined from the direct intensity of K-series radiation. In the analysis of zinc concentrates the same conditions of recording and excitation were used as in the case of lead concentrates, but the measurements were conducted in saturated layers. It is demonstrated that the use of germanium semiconductor detectors in combination with the suggested methods of measurements makes it possible to perform determination of iron, zinc and lead in zinc and lead concentrates with permissible error

  8. Field-portable high-resolution EDXRF analysis with HgI2-detector-based instrumentation

    International Nuclear Information System (INIS)

    Berry, P.F.; Little, S.R.; Voots, G.R.

    1992-01-01

    Energy dispersive x-ray fluorescence (EDXRF) analysis is well known for its efficient use of x-ray detector technology for simultaneous multielement determination. Low-intensity excitation, such as from a radioisotope source, can thus be employed and has enabled the design of many types of truly portable EDXRF instrumentation. Portable design, however, has not been without significant compromise in analytical performance because of the limited x-ray resolving power of prior detection methods, except by the use of a cryogenically operated detector. The developments we refer to stem from the use of a comparatively new x-ray detection device fabricated from mercuric iodide (HgI 2 ). For this detector, only a modest degree of cooling is required to achieve an energy resolution of > 300 eV. Two field-portable instrument designs of different hand-held measurement probe configurations are available that have applications for industrial quality assurance and environmental screening

  9. The TOTEM Detector at LHC

    CERN Document Server

    Ruggiero, G; Aspell, P; Atanassov, I; Avati, V; Berardi, V; Berretti, M; Bozzo, M; Brücken, E; Buzzo, A; Cafagna, F; Calicchio, M; Catanesi, M G; Ciocci, M A; Csanád, M; Csörgö, T; Deile, M; Dénes, E; Dimovasili, E; Doubek, M; Eggert, K; Ferro, F; Garcia, F; Giani, S; Greco, V; Grzanka, L; Heino, J; Hilden, T; Janda, M; Kaspar, J; Kopal, J; Kundrát, V; Kurvinen, K; Lami, S; Latino, G; Lauhakangas, R; Lippmaa, E; Lokajícek, M; Lo Vetere, M; Lucas Rodriguez, F; Macrí, M; Magazzù, G; Minutoli, S; Niewiadomski, H; Notarnicola, G; Novak, T; Oliveri, E; Oljemark, F; Orava, R; Oriunno, M; Österberg, K; Pedreschi, E; Petäjäjärvi, J; Quinto, M; Radermacher, E; Radicioni, E; Ravotti, F; Robutti, E; Ropelewski, L; Rummel, A; Saarikko, H; Sanguinetti, G; Santroni, A; Scribano, A; Sette, G; Snoeys, W; Spearman, W; Spinella, F; Ster, A; Taylor, C; Trummal, A; Turini, N; Vacek, V; Vitek, M; Whitmore, J; Wu, J

    2010-01-01

    The TOTEM experiment, small in size compared to the others at the LHC, is dedicated to the measurement of the total proton-proton cross-section with the luminosity-independent method and to the study of elastic and diffractive scattering. To achieve optimum forward coverage for charged particles emitted by the pp collisions in the interaction point IP5, two tracking telescopes, T1 and T2, are installed on each side in the pseudo-rapidity region between 3.1 and 6.5, and Roman Pot (RP) stations are placed at distances of 147m and 220m from IP5. The telescope closest to the interaction point (T1, centered at z = 9 m) consists of Cathode Strip Chambers (CSC), while the second one (T2, centered at 13.5 m), makes use of Gas Electron Multipliers (GEM). The proton detectors in the RPs are silicon devices designed by TOTEM with the specific objective of reducing down to a few tens of microns the insensitive area at the edge. High efficiency as close as possible to the physical detector boundary is an essential feature...

  10. The TOTEM Detector at LHC

    CERN Document Server

    Ruggiero, G; Aspell, P; Atanassov, I; Avati, V; Berardi, V; Berretti, M; Bozzo, M; Brücken, E; Buzzo, A; Cafagna, F; Calicchio, M; Catanesi, M G; Ciocci, M A; Csanád, M; Csörgö, T; Deile, M; Dénes, E; Dimovasili, E; Doubek, M; Eggert, K; Ferro, F; Garcia, F; Giani, S; Greco, V; Grzanka, L; Heino, J; Hilden, T; Janda, M; Kaspar, J; Kopal, J; Kundrát, V; Kurvinen, K; Lami, S; Latino, G; Lauhakangas, R; Lippmaa, E; Lokajícek, M; Lo Vetere, M; Lucas Rodriguez, F; Macrí, M; Magazzù, G; Minutoli, S; Niewiadomski, H; Notarnicola, G; Novak, T; Oliveri, E; Oljemark, F; Orava, R; Oriunno, M; Österberg, K; Palazzi, P; Pedreschi, E; Petäjäjärvi, J; Quinto, M; Radermacher, E; Radicioni, E; Ravotti, F; Robutti, E; Ropelewski, L; Rummel, A; Saarikko, H; Sanguinetti, G; Santroni, A; Scribano, A; Sette, G; Snoeys, W; Spearman, W; Spinella, F; Ster, A; Taylor, C; Trummal, A; Turini, N; Vacek, V; Vitek, M; Whitmore, J; Wu, J

    2010-01-01

    The TOTEM experiment, small in size compared to the others at the LHC, is dedicated to the measurement of the total proton–proton cross-sections with a luminosity-independent method and to the study of elastic and diffractive scattering at the LHC. To achieve optimum forward coverage for charged particles emitted by the pp collisions in the IP5 interaction point, two tracking telescopes, T1 and T2, will be installed on each side in the pseudo-rapidity region between 3.1 and 6.5, and Roman Pot stations will be placed at distances of 147 and 220 m from IP5. The telescope closest to the interaction point (T1, centred at z=9 m) consists of Cathode Strip Chambers (CSC), while the second one (T2, centred at 13.5 m), makes use of Gas Electron Multipliers (GEM). The proton detectors in the Roman Pots are silicon devices designed by TOTEM with the specific objective of reducing down to a few tens of microns the insensitive area at the edge. High efficiency as close as possible to the physical detector boundary is an...

  11. The German press coverage on France after World War II

    Directory of Open Access Journals (Sweden)

    Susanne Jaeger

    2004-07-01

    Full Text Available How is the continuing reconciliation process between the former "hereditary enemies" Germany and France reflected in German daily newspapers between 1946 and 1970? Using quantitative content analysis, a representative sample of coverage of France and French-related topics published during this period was examined with an emphasis on a the choice of news topics and possible deviations from the predictions of Galtung’s news-factors model and on b how protagonists and events were portrayed in these articles. A further qualitative analysis was made of some promising journalistic attempts to achieve "constructive" coverage during the same period. This was intended a to determine whether and how several theoretical deductions from Kempf’s conflict model of de-escalation processes are manifest in post-conflict coverage and b to identify the stylistic "tools" journalists used – even unintentionally – to further a better understanding of the former enemy and – in the long run – to build peace and reconciliation between Germany and France. The overarching questions addressed by this study are: (What can we learn from coverage during a successful reconciliation process, and how can these lessons be transferred to contemporary coverage of post-war processes? Major findings of the two studies will be presented.

  12. US Media Coverage of Tobacco Industry Corporate Social Responsibility Initiatives.

    Science.gov (United States)

    McDaniel, Patricia A; Lown, E Anne; Malone, Ruth E

    2018-02-01

    Media coverage of tobacco industry corporate social responsibility (CSR) initiatives represents a competitive field where tobacco control advocates and the tobacco industry vie to shape public and policymaker understandings about tobacco control and the industry. Through a content analysis of 649 US news items, we examined US media coverage of tobacco industry CSR and identified characteristics of media items associated with positive coverage. Most coverage appeared in local newspapers, and CSR initiatives unrelated to tobacco, with non-controversial beneficiaries, were most commonly mentioned. Coverage was largely positive. Tobacco control advocates were infrequently cited as sources and rarely authored opinion pieces; however, when their voices were included, coverage was less likely to have a positive slant. Media items published in the South, home to several tobacco company headquarters, were more likely than those published in the West to have a positive slant. The absence of tobacco control advocates from media coverage represents a missed opportunity to influence opinion regarding the negative public health implications of tobacco industry CSR. Countering the media narrative of virtuous companies doing good deeds could be particularly beneficial in the South, where the burdens of tobacco-caused disease are greatest, and coverage of tobacco companies more positive.

  13. Determination of sodium bis(2-ethylhexylsulfosuccinate (AOT surfactant with liquid chromatography: Comparative study of evaporative light scattering detector, ultraviolet detector and conductivity detector

    Directory of Open Access Journals (Sweden)

    Ho Ryul Ryu

    2010-03-01

    Full Text Available This work presents comparison of performance of ultraviolet (UV detector, conductivity detector (CD and evaporative light scattering detector (ELSD in terms of quantitative analysis of AOT (sodium bis(2-ethylhexylsulfosuccinate using liquid chromatography. The employed chromatographic condition, including an acetonitrile/water (45:55, v/v isocratic eluent system, is suitable for the three different detectors, and the figures of merits obtained by building up calibration plots are compared. The sensitivities of the detectors are in the order of ELSD ≈ CD >> UV detector. The linear range for quantification of AOT depends on the type of detector: the lower limits are in the order of UV detector (207 ㎍ mL-1 < CD (310 ㎍ mL-1 << ELSD (930 ㎍ mL-1, while the upper limits are 3720 ㎍ mL-1 for all the detectors (the maximum concentration of injected standard solution. The detection limits are 155 ㎍ mL-1 for ELSD, 78 ㎍ mL-1 for UV detector and 13 ㎍ mL-1 for CD, respectively. The figures of merit for each detector could be a guideline in choosing a detector in quantization of AOT. Furthermore, application of the chromatographic method to two commercial products is demonstrated.

  14. The impact of eliminating within-country inequality in health coverage on maternal and child mortality: a Lives Saved Tool analysis

    Directory of Open Access Journals (Sweden)

    Adrienne Clermont

    2017-11-01

    Full Text Available Abstract Background Inequality in healthcare across population groups in low-income countries is a growing topic of interest in global health. The Lives Saved Tool (LiST, which uses health intervention coverage to model maternal, neonatal, and child health outcomes such as mortality rates, can be used to analyze the impact of within-country inequality. Methods Data from nationally representative household surveys (98 surveys conducted between 1998 and 2014, disaggregated by wealth quintile, were used to create a LiST analysis that models the impact of scaling up health intervention coverage for the entire country from the national average to the rate of the top wealth quintile (richest 20% of the population. Interventions for which household survey data are available were used as proxies for other interventions that are not measured in surveys, based on co-delivery of intervention packages. Results For the 98 countries included in the analysis, 24–32% of child deaths (including 34–47% of neonatal deaths and 16–19% of post-neonatal deaths could be prevented by scaling up national coverage of key health interventions to the level of the top wealth quintile. On average, the interventions with most unequal coverage rates across wealth quintiles were those related to childbirth in health facilities and to water and sanitation infrastructure; the most equally distributed were those delivered through community-based mass campaigns, such as vaccines, vitamin A supplementation, and bednet distribution. Conclusions LiST is a powerful tool for exploring the policy and programmatic implications of within-country inequality in low-income, high-mortality-burden countries. An “Equity Tool” app has been developed within the software to make this type of analysis easily accessible to users.

  15. Isotope detectors and radiation detectors for test reliability techniqui. A preliminary project

    International Nuclear Information System (INIS)

    Christell, R.

    1977-03-01

    A survey is done of small and simple components for use as detectors for ionizing radiation, as well as different methods and components producing images of radiation fields based on position sensitive detectors. The investigation has resulted in a system for detection of stones in wood. In a second project isotope excited x ray fluorescence has been used for analysis of material resulting from wear of mechanical components. A facility for analysis has been built and test analysis has been performed. Methods for continous wear control with possibility to forecast breakdowns have been investigated. (K.K.)

  16. Preliminary results of the Moon shadow using ARGO-YBJ detector

    Energy Technology Data Exchange (ETDEWEB)

    Wang Yungang [Institute of High Energy Physics, Chinese Academy of Sciences 19B Yuquan Lu, Shijingshan, Beijing, 100049 (China)], E-mail: wangyg@mail.ihep.ac.cn

    2008-01-15

    ARGO-YBJ is a 'full coverage' air shower detector consisting of Resistive Plate Chambers(RPCs) at the Yangbajing High Altitude Cosmic Ray Laboratory (Tibet, China) at 4300 m a.s.l. (lat=30.11{sup o} N, long=90.53{sup o} E). Using the data collected with a carpet of RPCs (1900 m{sup 2}, about 1/3 of the whole ARGO-YBJ detector), the cosmic ray shadowing effect due to the Moon was studied. The 50% angular resolution is found to be {approx}1.2{sup o} with the Chess-board method and the Moon shadow with a significance of 4.9 {sigma} is found displaced by 0.7{sup o} westward and 0.5{sup o} northward with respect to the expected position by the equi-zenith angle Method.

  17. Detector unit for X-ray diagnosis

    International Nuclear Information System (INIS)

    Svobodova, B.; Hamouz, J.; Pavlicek, Z.; Jursova, L.; Pohanka, J.

    1983-01-01

    The detector unit is applied in the medical and industrial X-ray diagnosis and analysis. It controls the X-ray dosing by exposure and brightness automation. The detector field is generated from a carrier, in which detector elements with light quides are situated, tapped on optical detectors with level converters outside the detector field. The detector field and the optical detectors with level converters are located in a light-resistent shell. This arrangement of the detector unit allows to use the impulse skiascopy instead of permanent X-ray examinations or the skiagraphy with multienergy levels which considerably improves the diagnostic value of the exposures and the working conditions. 1 cl., 1 fig

  18. An Analysis of Delay-based and Integrator-based Sequence Detectors for Grid-Connected Converters

    DEFF Research Database (Denmark)

    Khazraj, Hesam; Silva, Filipe Miguel Faria da; Bak, Claus Leth

    2017-01-01

    -signal cancellation operators are the main members of the delay-based sequence detectors. The aim of this paper is to provide a theoretical and experimental comparative study between integrator and delay based sequence detectors. The theoretical analysis is conducted based on the small-signal modelling......Detecting and separating positive and negative sequence components of the grid voltage or current is of vital importance in the control of grid-connected power converters, HVDC systems, etc. To this end, several techniques have been proposed in recent years. These techniques can be broadly...... classified into two main classes: The integrator-based techniques and Delay-based techniques. The complex-coefficient filter-based technique, dual second-order generalized integrator-based method, multiple reference frame approach are the main members of the integrator-based sequence detector and the delay...

  19. Pertussis: herd immunity and vaccination coverage in St Lucia.

    Science.gov (United States)

    Cooper, E; Fitch, L

    1983-11-12

    In a single complete epidemic in St Lucia, an island too small to support constant clinical pertussis, the pertussis case rates in small communities (villages and small towns) with differing levels of vaccination coverage of young children were compared. The association between greater vaccination coverage and greater herd immunity was clear, despite the imperfect protection given to individuals. An analysis in terms of population dynamics is evidence against the theory that endemic subclinical pertussis maintains transmission in a highly vaccinated population. We suggest that with a homogeneous vaccination coverage of 80% of 2-year-old children pertussis might be eradicated from the island, and that this is a practicable experiment.

  20. Application of neural networks to digital pulse shape analysis for an array of silicon strip detectors

    Energy Technology Data Exchange (ETDEWEB)

    Flores, J.L. [Dpto de Ingeniería Eléctrica y Térmica, Universidad de Huelva (Spain); Martel, I. [Dpto de Física Aplicada, Universidad de Huelva (Spain); CERN, ISOLDE, CH 1211 Geneva, 23 (Switzerland); Jiménez, R. [Dpto de Ingeniería Electrónica, Sist. Informáticos y Automática, Universidad de Huelva (Spain); Galán, J., E-mail: jgalan@diesia.uhu.es [Dpto de Ingeniería Electrónica, Sist. Informáticos y Automática, Universidad de Huelva (Spain); Salmerón, P. [Dpto de Ingeniería Eléctrica y Térmica, Universidad de Huelva (Spain)

    2016-09-11

    The new generation of nuclear physics detectors that used to study nuclear reactions is considering the use of digital pulse shape analysis techniques (DPSA) to obtain the (A,Z) values of the reaction products impinging in solid state detectors. This technique can be an important tool for selecting the relevant reaction channels at the HYDE (HYbrid DEtector ball array) silicon array foreseen for the Low Energy Branch of the FAIR facility (Darmstadt, Germany). In this work we study the feasibility of using artificial neural networks (ANNs) for particle identification with silicon detectors. Multilayer Perceptron networks were trained and tested with recent experimental data, showing excellent identification capabilities with signals of several isotopes ranging from {sup 12}C up to {sup 84}Kr, yielding higher discrimination rates than any other previously reported.

  1. Large solid angle detectors (low energy)

    International Nuclear Information System (INIS)

    L'Hote, D.

    1988-01-01

    This lecture deals with large solid angle detectors used in low energy experiments (mainly in Nuclear Physics). The reasons for using such detectors are discussed, and several basic principles of their design are presented. Finally, two examples of data analysis from such detectors are given [fr

  2. Analysis of fold distributions of segmented clover detectors

    International Nuclear Information System (INIS)

    Bhattacharya, Pintu; Kshetri, Ritesh

    2015-01-01

    We have studied the effect of segmentation on the full energy energy deposition of a gamma-ray through the studies on fold distribution. The response of seven segmented TIGRESS detectors up to an energy of 8 MeV has been studied by utilizing standard sources of 152 Eu, 56,60 Co and a radioactive 11 Be beam with an energy of 16.5 MeV. Experiment was performed at the ISAC-II facility at TRIUMF, using a thick gold target. The β¯ decay of 11 Be (τ 1/2 = 13.81(8) sec) produces high energy gamma-rays up to 7974 keV. A 1 mm thick annular double-sided silicon detector of the BAMBINO detector, was mounted 19.4 mm downstream of the target position and used for detection of the electrons in coincidence with the gamma-rays from the seven TIGRESS detectors. The master trigger allowed data to be collected either in Ge singles mode or with a Ge-Si coincidence condition. Standard sources of 152 Eu and 56,60 Co were also used to obtain low energy data

  3. Linguistic analysis of IPCC summaries for policymakers and associated coverage

    Science.gov (United States)

    Barkemeyer, Ralf; Dessai, Suraje; Monge-Sanz, Beatriz; Renzi, Barbara Gabriella; Napolitano, Giulio

    2016-03-01

    The Intergovernmental Panel on Climate Change (IPCC) Summary for Policymakers (SPM) is the most widely read section of IPCC reports and the main springboard for the communication of its assessment reports. Previous studies have shown that communicating IPCC findings to a variety of scientific and non-scientific audiences presents significant challenges to both the IPCC and the mass media. Here, we employ widely established sentiment analysis tools and readability metrics to explore the extent to which information published by the IPCC differs from the presentation of respective findings in the popular and scientific media between 1990 and 2014. IPCC SPMs clearly stand out in terms of low readability, which has remained relatively constant despite the IPCC’s efforts to consolidate and readjust its communications policy. In contrast, scientific and quality newspaper coverage has become increasingly readable and emotive. Our findings reveal easy gains that could be achieved in making SPMs more accessible for non-scientific audiences.

  4. Analysis of self-powered gamma ray detector with directional discrimination

    International Nuclear Information System (INIS)

    Levert, F.E.; Beyerlein, R.A.; Cox, S.A.

    1979-01-01

    The results of a combined Monte Carlo simulation and experimental investigation of the directional and energy dependent response of a self-powered gamma detector with a flat plate Pb-C central electrode are presented. The electron yield of the central electrode in a three dimensional mockup of the detector was calculated for photons of several discrete energies, emanating from an infinitely thin planar source, incident on the outer surface of the detector. Separate computations were done with the source facing the lead side and carbon side of the central electrode. Experimental measurements with a detector that closely matched the design used in the simulation were conducted in a graphite column next to a neutron leakage face of a low flux reactor. A localized gamma ray source was created by positioning a 235 U strip between the leakage face of the reactor and the detector. A comparison of results obtained in both cases showed good agreement. Also experimental measurements to determine the effect of the thickness of lead shielding surrounding the outer wall of the detector and space charge in the vacuum insulator between the central electrode and the inner wall on the response of the detector were performed. (Auth.)

  5. An Assessment of Media Coverage of the B-2 Stealth Bomber

    Science.gov (United States)

    1990-01-01

    15 Sharon M. Friedman, Carole M. Gorney, and Brenda P. Egolf, "Reporting on Radiation: A Content Analysis of Chernobyl Coverage," Journal of...Mitterrand," Political Science Quarterly, 39 (1987): 103-122. 1 29 Jane Blankenship, Serefa Mendez - Mendez , Jong Guen King and Joseph Giodan, "Initial... Carole M. Gorney and Brenda P. Egolf, "Reporting on Radiation: A Content Analysis of Chernobyl Coverage," Journal of Communication, Summer3 (1987

  6. Improving the spatial resolution in CZT detectors using charge sharing effect and transient signal analysis: Simulation study

    Energy Technology Data Exchange (ETDEWEB)

    Zheng, Xiaoqing; Cheng, Zeng [Department of Electrical and Computer Engineering, McMaster University (Canada); Deen, M. Jamal, E-mail: jamal@mcmaster.ca [Department of Electrical and Computer Engineering, McMaster University (Canada); School of Biomedical Engineering, McMaster University (Canada); Peng, Hao, E-mail: penghao@mcmaster.ca [Department of Electrical and Computer Engineering, McMaster University (Canada); School of Biomedical Engineering, McMaster University (Canada); Department of Medical Physics, McMaster University, Ontario L8S 4K1, Hamilton (Canada)

    2016-02-01

    Cadmium Zinc Telluride (CZT) semiconductor detectors are capable of providing superior energy resolution and three-dimensional position information of gamma ray interactions in a large variety of fields, including nuclear physics, gamma-ray imaging and nuclear medicine. Some dedicated Positron Emission Tomography (PET) systems, for example, for breast cancer detection, require higher contrast recovery and more accurate event location compared with a whole-body PET system. The spatial resolution is currently limited by electrode pitch in CZT detectors. A straightforward approach to increase the spatial resolution is by decreasing the detector electrode pitch, but this leads to higher fabrication cost and a larger number of readout channels. In addition, inter-electrode charge spreading can negate any improvement in spatial resolution. In this work, we studied the feasibility of achieving sub-pitch spatial resolution in CZT detectors using two methods: charge sharing effect and transient signal analysis. We noted that their valid ranges of usage were complementary. The dependences of their corresponding valid ranges on electrode design, depth-of-interaction (DOI), voltage bias and signal triggering threshold were investigated. The implementation of these two methods in both pixelated and cross-strip configuration of CZT detectors were discussed. Our results show that the valid range of charge sharing effect increases as a function of DOI, but decreases with increasing gap width and bias voltage. For a CZT detector of 5 mm thickness, 100 µm gap and biased at 400 V, the valid range of charge sharing effect was found to be about 112.3 µm around the gap center. This result complements the valid range of the transient signal analysis within one electrode pitch. For a signal-to-noise ratio (SNR) of ~17 and preliminary measurements, the sub-pitch spatial resolution is expected to be ~30 µm and ~250 µm for the charge sharing and transient signal analysis methods

  7. Measurement and analysis of field-induced crystallographic texture using curved position-sensitive diffraction detectors

    DEFF Research Database (Denmark)

    Simons, Hugh; Daniels, John E.; Studer, Andrew J.

    2014-01-01

    This paper outlines measurement and analysis methodologies created for determining the structural responses of electroceramics to an electric field. A sample stage is developed to apply electric fields to ceramic materials at elevated temperatures during neutron diffraction experiments. The tested...... employing a curved positive sensitive detector. Methodologies are proposed to account for the geometrical effects when vector fields are applied to textured materials with angularly dispersive detector geometries. Representative results are presented for the ferroelectric (Bi1/2Na1/2)TiO3-6%BaTiO3 (BNT-6BT...

  8. Radiation damage in silicon detectors

    CERN Document Server

    Lindström, G

    2003-01-01

    Radiation damage effects in silicon detectors under severe hadron and gamma-irradiation are surveyed, focusing on bulk effects. Both macroscopic detector properties (reverse current, depletion voltage and charge collection) as also the underlying microscopic defect generation are covered. Basic results are taken from the work done in the CERN-RD48 (ROSE) collaboration updated by results of recent work. Preliminary studies on the use of dimerized float zone and Czochralski silicon as detector material show possible benefits. An essential progress in the understanding of the radiation-induced detector deterioration had recently been achieved in gamma irradiation, directly correlating defect analysis data with the macroscopic detector performance.

  9. The frequency analysis particle resolution technique of 6LiI(Eu) scintillation detector

    International Nuclear Information System (INIS)

    Duan Shaojie

    1995-01-01

    To measure the distribution and rate of tritium production by neutron in a 6 LiD sphere, the 6 LiI(Eu) scintillation detector was used. In the measurement, the frequency analysis particle resolution technique was used. The experiment was completed perfectly

  10. DNA barcoding in the media: does coverage of cool science reflect its social context?

    Science.gov (United States)

    Geary, Janis; Camicioli, Emma; Bubela, Tania

    2016-09-01

    Paul Hebert and colleagues first described DNA barcoding in 2003, which led to international efforts to promote and coordinate its use. Since its inception, DNA barcoding has generated considerable media coverage. We analysed whether this coverage reflected both the scientific and social mandates of international barcoding organizations. We searched newspaper databases to identify 900 English-language articles from 2003 to 2013. Coverage of the science of DNA barcoding was highly positive but lacked context for key topics. Coverage omissions pose challenges for public understanding of the science and applications of DNA barcoding; these included coverage of governance structures and issues related to the sharing of genetic resources across national borders. Our analysis provided insight into how barcoding communication efforts have translated into media coverage; more targeted communication efforts may focus media attention on previously omitted, but important topics. Our analysis is timely as the DNA barcoding community works to establish the International Society for the Barcode of Life.

  11. A Content Analysis of Smokeless Tobacco Coverage in U.S. Newspapers and News Wires

    Science.gov (United States)

    2013-01-01

    Introduction: Research attention on smokeless tobacco (SLT) has focused on SLT use, health risks, harm-reduction potential, and risk perceptions, but few studies have examined mediated communications about SLT. This study aims to contribute to the literature by providing the first description of SLT coverage in the news, an important communication channel given its ability to educate and shape public opinion about tobacco issues. Methods: A content analysis was conducted on SLT-related news and opinion articles between 2006 and 2010 from top circulating national and state newspapers and select news wires. Articles were coded for the main SLT topic, SLT risk references, and slant of opinion articles. Results: SLT was discussed in news/feature articles (n = 677) in terms of business (28%), new products, product regulation and harm reduction (19%), prevention/cessation (11.4%), taxation (10.2%), profiles/trends in use (9%), bans (8.1%), and tobacco industry promotional activities (4.9%). Health risk references (i.e., addictiveness, carcinogenicity, and specific health effects including oral cancer) were found in 40% of articles, though frequency differed by article topic. Although the majority of opinion articles (n = 176) conveyed an anti-SLT slant (64%), 25.6% were pro-SLT. Conclusions: SLT topics of both national and local importance are covered in the news. Public health professionals can participate in SLT coverage by sending in press releases about new study findings, events, or resources and by submitting opinion pieces to share views or respond to previous coverage. Research on SLT news should continue given its potential to shape the public’s SLT knowledge and opinions. PMID:23288875

  12. Uncertainty analysis in the simulation of an HPGe detector using the Monte Carlo Code MCNP5

    International Nuclear Information System (INIS)

    Gallardo, Sergio; Pozuelo, Fausto; Querol, Andrea; Verdu, Gumersindo; Rodenas, Jose; Ortiz, J.; Pereira, Claubia

    2013-01-01

    A gamma spectrometer including an HPGe detector is commonly used for environmental radioactivity measurements. Many works have been focused on the simulation of the HPGe detector using Monte Carlo codes such as MCNP5. However, the simulation of this kind of detectors presents important difficulties due to the lack of information from manufacturers and due to loss of intrinsic properties in aging detectors. Some parameters such as the active volume or the Ge dead layer thickness are many times unknown and are estimated during simulations. In this work, a detailed model of an HPGe detector and a petri dish containing a certified gamma source has been done. The certified gamma source contains nuclides to cover the energy range between 50 and 1800 keV. As a result of the simulation, the Pulse Height Distribution (PHD) is obtained and the efficiency curve can be calculated from net peak areas and taking into account the certified activity of the source. In order to avoid errors due to the net area calculation, the simulated PHD is treated using the GammaVision software. On the other hand, it is proposed to use the Noether-Wilks formula to do an uncertainty analysis of model with the main goal of determining the efficiency curve of this detector and its associated uncertainty. The uncertainty analysis has been focused on dead layer thickness at different positions of the crystal. Results confirm the important role of the dead layer thickness in the low energy range of the efficiency curve. In the high energy range (from 300 to 1800 keV) the main contribution to the absolute uncertainty is due to variations in the active volume. (author)

  13. Uncertainty analysis in the simulation of an HPGe detector using the Monte Carlo Code MCNP5

    Energy Technology Data Exchange (ETDEWEB)

    Gallardo, Sergio; Pozuelo, Fausto; Querol, Andrea; Verdu, Gumersindo; Rodenas, Jose, E-mail: sergalbe@upv.es [Universitat Politecnica de Valencia, Valencia, (Spain). Instituto de Seguridad Industrial, Radiofisica y Medioambiental (ISIRYM); Ortiz, J. [Universitat Politecnica de Valencia, Valencia, (Spain). Servicio de Radiaciones. Lab. de Radiactividad Ambiental; Pereira, Claubia [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Departamento de Engenharia Nuclear

    2013-07-01

    A gamma spectrometer including an HPGe detector is commonly used for environmental radioactivity measurements. Many works have been focused on the simulation of the HPGe detector using Monte Carlo codes such as MCNP5. However, the simulation of this kind of detectors presents important difficulties due to the lack of information from manufacturers and due to loss of intrinsic properties in aging detectors. Some parameters such as the active volume or the Ge dead layer thickness are many times unknown and are estimated during simulations. In this work, a detailed model of an HPGe detector and a petri dish containing a certified gamma source has been done. The certified gamma source contains nuclides to cover the energy range between 50 and 1800 keV. As a result of the simulation, the Pulse Height Distribution (PHD) is obtained and the efficiency curve can be calculated from net peak areas and taking into account the certified activity of the source. In order to avoid errors due to the net area calculation, the simulated PHD is treated using the GammaVision software. On the other hand, it is proposed to use the Noether-Wilks formula to do an uncertainty analysis of model with the main goal of determining the efficiency curve of this detector and its associated uncertainty. The uncertainty analysis has been focused on dead layer thickness at different positions of the crystal. Results confirm the important role of the dead layer thickness in the low energy range of the efficiency curve. In the high energy range (from 300 to 1800 keV) the main contribution to the absolute uncertainty is due to variations in the active volume. (author)

  14. Taking stock: A meta-analysis of studies on the media's coverage of science.

    Science.gov (United States)

    Schäfer, Mike S

    2012-08-01

    The presentation of science in the mass media is one of the most important questions facing social scientists who analyse science. Accordingly, media coverage of science has been a constant focal point in the respective literature, and a flurry of such publications has appeared in the past few years. Yet the activity and growth of the respective research have not been accompanied by systematic overviews. This article aims to provide such an overview by means of a meta-analysis: it analyses existing studies systematically and provides an empirical overview of the literature. The analysis shows that while the research field grew significantly in the past few years and employs a variety of research strategies and methods, it has been biased in three ways: mainly natural sciences (and namely biosciences and medicine), Western countries, and print media have been analysed.

  15. Configuration Design of Detector Shielding for Gamma Prompt Analysis

    International Nuclear Information System (INIS)

    Elin-Nuraini; Darsono; Elisabeth

    2000-01-01

    Configuration on design of detector shielding for gamma prompt analysishas been performed. The aim of this design is to obtain effective shieldingmaterial and configuration that able to protect the detector for fastneutron. The result shown that detector shielding configuration that obtainedby configuration of water and concrete, would be able to absorb fast neutronup to 99.5 %. The neutron flux that passed through shielding configuration is2.4 x 10 3 n/cm 2 dt, in the detector position of 60 cm (forward neutron beamdirection) on the X axis and 30 cm (side ward neutron beam direction) on theZ axis of target. On this position (60,30) counting result was 104358 for Pbcollimator and 246652 for PVC collimator. From examination result shown thatthe weight of silicon is in order 175 gram. (author)

  16. Improving the Methods for Accounting the Coverages of Payments to Employees

    Directory of Open Access Journals (Sweden)

    Zhurakovska Iryna V.

    2017-03-01

    Full Text Available The article is aimed at exploring the theoretical and practical problems of accounting the coverages of payments to employees and developing on this basis ways of addressing them. An analysis of both the international and the national accounting standards, practices of domestic enterprises, as well as scientific works of scientists, has helped to identify the problematic issues of accounting the coverages of payments to employees, including: ignoring the disclosure in accounting and reporting, absence of an adequate documentary support, complexity of the calculation methods, etc. The authors have suggested ways to improve accounting of payments to employees: documentation of coverages through the development of a Statement of the accrued coverages, simplification of calculation of payments to employees together with the related reflecting in the analytical accounting, disclosure in the accounting policy, and so forth. Such decisions would improve accounting the coverages of payments to employees, increase the frequency of applying such coverages in enterprises and their disclosure in the financial statements.

  17. A Comparison of Coverage of Speech and Press Verdicts of Supreme Court.

    Science.gov (United States)

    Hale, F. Dennis

    1979-01-01

    An analysis of the coverage by ten newspapers of 20 United States Supreme Court decisions concerning freedom of the press and 20 decisions concerning freedom of speech revealed that the newspapers gave significantly greater coverage to the press decisions. (GT)

  18. Coverage for SCS Pre-1941 Aerial Photography

    Data.gov (United States)

    Earth Data Analysis Center, University of New Mexico — This shapefile was generated by the U.S. Bureau of Land Management (BLM) at the New Mexico State Office to show the coverage for the Pre-1941 aerial photography...

  19. Newspaper coverage of mental illness in England 2008-2011.

    Science.gov (United States)

    Thornicroft, Amalia; Goulden, Robert; Shefer, Guy; Rhydderch, Danielle; Rose, Diana; Williams, Paul; Thornicroft, Graham; Henderson, Claire

    2013-04-01

    Better newspaper coverage of mental health-related issues is a target for the Time to Change (TTC) anti-stigma programme in England, whose population impact may be influenced by how far concurrent media coverage perpetuates stigma and discrimination. To compare English newspaper coverage of mental health-related topics each year of the TTC social marketing campaign (2009-2011) with baseline coverage in 2008. Content analysis was performed on articles in 27 local and national newspapers on two randomly chosen days each month. There was a significant increase in the proportion of anti-stigmatising articles between 2008 and 2011. There was no concomitant proportional decrease in stigmatising articles, and the contribution of mixed or neutral elements decreased. These findings provide promising results on improvements in press reporting of mental illness during the TTC programme in 2009-2011, and a basis for guidance to newspaper journalists and editors on reporting mental illness.

  20. Danish Media coverage of 22/7

    DEFF Research Database (Denmark)

    Hervik, Peter; Boisen, Sophie

    2013-01-01

    ’s Danish connections through an analysis of the first 100 days of Danish media coverage. We scrutinised 188 articles in the largest daily newspapers to find out how Danish actors related to ABB’s ideas. The key argument is that the discourses and opinions reflect pre-existing opinions and entrenched...

  1. Prototyping of larger structures for the Phase-II upgrade of the pixel detector of the ATLAS experiment

    CERN Document Server

    Alvarez Feito, Diego; The ATLAS collaboration

    2017-01-01

    For the high luminosity era of the Large Hadron Collider (HL-LHC) it is forseen to replace the current inner tracker of the ATLAS experiment with a new detector to cope with the occuring increase in occupancy, bandwidth and radiation damage. It will consist of an inner pixel and outer strip detector aiming to provide tracking coverage up to |η|<4. The layout of the pixel detector is foreseen to consist of five layers of pixel silicon sensor modules in the central region and several ring-shaped layers in the forward region. It results in up to 14 m² of silicon depending on the selected layout. Beside the challenge of radiation hardness and high-rate capable silicon sensors and readout electronics many system aspects have to be considered for a fully functional detector. Both stable and low mass mechanical structures and services are important. Within the collaboration a large effort is started to prototype larger detector structures for both the central and forward region of the detector. The aspect of sy...

  2. PC based analysis of gamma ray spectra generated by semiconductor detectors

    International Nuclear Information System (INIS)

    Abani, M.C.; Madan, V.K.

    1993-01-01

    This report describes a spectrum analysis method and computer program for analysis of gamma spectra obtained by using semiconductor detectors and multichannel analysers. The analysis steps incorporated are smoothing, peak location using signal processing method of convolution, selectable background subtraction viz linear, polynomial and step like, peak fitting both for singlets and doublets using Mukoyama's method for evaluation of full width at half maximum and area evaluation including errors in its evaluation. The program also provides a facility for energy calibration. Typical results of analysis for singlets and doublets are included. This report is based on Wilson's report which has been modified and extended. The program is written in BASIC and its listing is included in the appendices. (author). 20 refs., 2 figs., 2 tabs

  3. Improving detector signal processing with pulse height analysis in Moessbauer spectrometers

    International Nuclear Information System (INIS)

    Pechousek, Jiri; Mashlan, Miroslav; Frydrych, Jiri; Jancik, Dalibor; Prochazka, Roman

    2007-01-01

    A plenty of different programming techniques and instrument solutions are used in the development of Moessbauer spectrometers. Each of them should provide a faster spectrum accumulation process, increased productivity of measurements, decreased nonlinearity of the velocity scale, etc. The well known virtual instrumentation programming method has been used to design a computer-based Moessbauer spectrometer. Hardware solution was based on two commercially-available PCI modules produced by National Instruments Co. Virtual Moessbauer spectrometer is implemented by the graphical programming language LabVIEW 7 Express. This design environment allows to emulate the multichannel analyzer on the digital oscilloscope platform. This is a novel method based on Waveform Peak Detection function which allows detailed analysis of the acquired signal. The optimal treatment of the detector signal from various detector types is achieved by mathematical processing only. As a result, the possibility of an increase of signal/noise ratio is presented.

  4. Analysis of neonicotinoids by gas chromatography coupled to nuclide 63Ni - Electron Capture Detector - GC/ECD

    International Nuclear Information System (INIS)

    Amaral, Priscila O.; Leao, Claudio; Redigolo, Marcelo M.; Crepaldi, Caike; Bustillos, Oscar V.

    2015-01-01

    Recently, several reports have been published discussing reduction in bee population which polymerizes cultures around the world this phenomenon is known as Colony Collapse Disorder (CCD). The phenomenon describes the lack of worker honeybees in the colony despite having pups and food. The causes of this problem are unknown but there are studies that claim that reduction of population of bees is linked to poisoning through insecticides specifically neonicotinoids. Among this type of pesticide are imidacloprid (C 9 H 10 ClN 5 O 2 ), clothianidin (C 6 H 8 ClN 5 O 2 S) and thiamethoxam (C 8 H 10 ClN 5 O 3 S). This paper presents the analysis of neonicotinoids - clothianidin, imidacloprid and thiamethoxam - by the technique of gas chromatography coupled to nuclide 63 Ni electron capture detector (GC/ECD). The electron capture detector (ECD) is a gas chromatography detector that has been used for the detection of organic halogens, nitriles, nitrates and organometallic compounds. The ECD detector ionizes the analytes by the beta particles from the nuclide sources 63 Ni within carrier gas N 2 . The electrons produced in this process are collected and create a current that are amplified and generates a chromatographic peak. Methodology and details of the analysis are present in this work. (author)

  5. Media Hyping and the "Herceptin Access Story": An Analysis of Canadian and UK Newspaper Coverage.

    Science.gov (United States)

    Abelson, Julia; Collins, Patricia A

    2009-02-01

    In May 2005, preliminary trial results pronouncing the effectiveness of Herceptin (trastuzumab) for treatment of early-stage breast cancer were disseminated at a high-profile scientific meeting. Herceptin was subsequently approved for use in the public healthcare systems of Canada and the United Kingdom, although the differences between the two decision timelines were stark. The authors compared UK and Canadian newspaper coverage of the Herceptin story to assess how it may have been "hyped" in each country. They analyzed a diverse sample of newspapers and coded clippings for reporters' framing of the drug's efficacy, costs and funding approval process. Canadian news coverage preceded formal publication of the trial results, while UK coverage mirrored major national events. Reporters in both countries used predominantly individualistic perspectives and framed Herceptin's efficacy in salutary terms. Framing of costs was more neutral in Canadian than in UK newspapers. Funding approval framing focused on inequitable access in the UK and timeliness in Canada. News coverage of drug access stories varies across jurisdictions in terms of intensity and some aspects of framing. Such variations likely reflect different journalistic practices and dominant political rhetoric. Greater attention should be given to the role that news coverage of drug access plays in shaping public opinion and policy action, especially when this coverage precedes scientific debate. Copyright © 2009 Longwoods Publishing.

  6. Analysis of Burst Observations by GLAST's LAT Detector

    International Nuclear Information System (INIS)

    Band, David L.; Digel, Seth W.

    2004-01-01

    Analyzing data from GLAST's Large Area Telescope (LAT) will require sophisticated techniques. The PSF and effective area are functions of both photon energy and the position in the field-of-view. During most of the mission the observatory will survey the sky continuously, and thus, the LAT will detect each count from a source at a different detector orientation; each count requires its own response function! The likelihood as a function of celestial position and photon energy will be the foundation of the standard analysis techniques. However, the 20 MeV-300 GeV emission at the time of the ∼ 100 keV burst emission (timescale of ∼ 10 s) can be isolated and analyzed because essentially no non-burst counts are expected within a PSF radius of the burst location during the burst. Both binned and unbinned (in energy) spectral fitting will be possible. Longer timescale afterglow emission will require the likelihood analysis that will be used for persistent sources

  7. Occulting Light Concentrators in Liquid Scintillator Neutrino Detectors

    Science.gov (United States)

    Buizza Avanzini, Margherita; Cabrera, Anatael; Dusini, Stefano; Grassi, Marco; He, Miao; Wu, Wenjie

    2017-09-01

    The experimental efforts characterizing the era of precision neutrino physics revolve around collecting high-statistics neutrino samples and attaining an excellent energy and position resolution. Next generation liquid-based neutrino detectors, such as JUNO, HyperKamiokande, etc, share the use of a large target mass, and the need of pushing light collection to the edge for maximal calorimetric information. Achieving high light collection implies considerable costs, especially when considering detector masses of several kt. A traditional strategy to maximize the effective photo-coverage with the minimum number of PMTs relies on Light Concentrators (LC), such as Winston Cones. In this paper, the authors introduce a novel concept called Occulting Light Concentrators (OLC), whereby a traditional LC gets tailored to a conventional PMT, by taking into account its single-photoelectron collection efficiency profile and thus occulting the worst performing portion of the photocathode. Thus, the OLC shape optimization takes into account not only the optical interface of the PMT, but also the maximization of the PMT detection performances. The light collection uniformity across the detector is another advantage of the OLC system. By considering the case of JUNO, we will show OLC capabilities in terms of light collection and energy resolution.

  8. Analytical methodologies for broad metabolite coverage of exhaled breath condensate.

    Science.gov (United States)

    Aksenov, Alexander A; Zamuruyev, Konstantin O; Pasamontes, Alberto; Brown, Joshua F; Schivo, Michael; Foutouhi, Soraya; Weimer, Bart C; Kenyon, Nicholas J; Davis, Cristina E

    2017-09-01

    Breath analysis has been gaining popularity as a non-invasive technique that is amenable to a broad range of medical uses. One of the persistent problems hampering the wide application of the breath analysis method is measurement variability of metabolite abundances stemming from differences in both sampling and analysis methodologies used in various studies. Mass spectrometry has been a method of choice for comprehensive metabolomic analysis. For the first time in the present study, we juxtapose the most commonly employed mass spectrometry-based analysis methodologies and directly compare the resultant coverages of detected compounds in exhaled breath condensate in order to guide methodology choices for exhaled breath condensate analysis studies. Four methods were explored to broaden the range of measured compounds across both the volatile and non-volatile domain. Liquid phase sampling with polyacrylate Solid-Phase MicroExtraction fiber, liquid phase extraction with a polydimethylsiloxane patch, and headspace sampling using Carboxen/Polydimethylsiloxane Solid-Phase MicroExtraction (SPME) followed by gas chromatography mass spectrometry were tested for the analysis of volatile fraction. Hydrophilic interaction liquid chromatography and reversed-phase chromatography high performance liquid chromatography mass spectrometry were used for analysis of non-volatile fraction. We found that liquid phase breath condensate extraction was notably superior compared to headspace extraction and differences in employed sorbents manifested altered metabolite coverages. The most pronounced effect was substantially enhanced metabolite capture for larger, higher-boiling compounds using polyacrylate SPME liquid phase sampling. The analysis of the non-volatile fraction of breath condensate by hydrophilic and reverse phase high performance liquid chromatography mass spectrometry indicated orthogonal metabolite coverage by these chromatography modes. We found that the metabolite coverage

  9. Aging Analysis of Micromegas Detectors for ATLAS New Small Wheel

    CERN Document Server

    Quinnan, Melissa

    2015-01-01

    In preparation for the coming High Luminosity Large Hadron Collider (HL-LHC) upgrade, the New Small Wheel (NSW) will replace the Small Wheel of the ATLAS Muon Spectrometer as part of the 2018 ATLAS Phase-I upgrade. Micromegas (MM) detectors will serve as one component of the NSW. These gaseous micro-mesh detectors will accommodate the higher luminosity and trigger rate of the future HL-LHC.In order to predict performance of MM after several years in the HL-LHC, radiation aging tests were conducted in the Gamma Irradiation Facility (GIF++) using a Cs 137 source. Two small MM prototype "T" chambers were irradiated and studied over the course of several months to accelerate the aging process and characterize chamber behavior. This report outlines a record of the aging process thus far and demonstrates techniques used to describe aging effects, namely measurements of average current, integrated charge, and gain. These will be used in the ongoing aging analysis of the T chambers and in future aging studies of the ...

  10. Pulse shape analysis for germanium detectors used in DM searches

    International Nuclear Information System (INIS)

    Sagdeev, I.R.; Drukier, A.K.; Welsh, D.J.; Klimenko, A.A.; Osetrov, S.B.; Smolnikov, A.A.

    1994-01-01

    Progress in Ge detector technology has resulted in ultralow backgrounds of less than 0.3 countskeV -1 kg -1 d -1 at energies between 6 and 9keV and from 12 to 20keV. Between 4 and 6keV it is less than 2 countskeV -1 kg -1 d -1 . Coupled with good energy resolution, 0.4keV FWHM at 10keV, this allows searches for DM particles with m≥qslant8GeV/c 2 .Electromagnetic interference (EMI) and acoustical pick-up are the main sources of background in the best Ge detectors. A PC-based on-line pulse shape analysis system is presented which permits rejection of large fraction of the EMI/acoustical background. The hardware uses a low cost, commercially available digital storage oscilloscope (DSO). The software consists of about 40000 lines of code in Pascal and assembly language. We tested this system using a low radioactive background Ge-system at the Baksan observatory. For low energy events (<100keV) this system permits improvement in the background by about 20-30%. ((orig.))

  11. Test beam & time resolution analysis for UFSD and CVD diamond detectors

    CERN Document Server

    Scali, Stefano

    2017-01-01

    The ever-increasing luminosity in particle physics, aimed at seeking new phenomena, has led to the need for radiation-hard detectors with a remarkable time resolution. To reach the goal several tests and data analysis has been performed but further development is still required. During my internship I have participated to the test of new sensors. After an introduction to the theoretical framework this report describes the data taking procedure using SPS beam at the H8 site in Prevessin. The second part describes the data analysis and extrapolation of the time resolution for many boards.

  12. Low-latency analysis pipeline for compact binary coalescences in the advanced gravitational wave detector era

    International Nuclear Information System (INIS)

    Adams, T; Buskulic, D; Germain, V; Marion, F; Mours, B; Guidi, G M; Montani, M; Piergiovanni, F; Wang, G

    2016-01-01

    The multi-band template analysis (MBTA) pipeline is a low-latency coincident analysis pipeline for the detection of gravitational waves (GWs) from compact binary coalescences. MBTA runs with a low computational cost, and can identify candidate GW events online with a sub-minute latency. The low computational running cost of MBTA also makes it useful for data quality studies. Events detected by MBTA online can be used to alert astronomical partners for electromagnetic follow-up. We outline the current status of MBTA and give details of recent pipeline upgrades and validation tests that were performed in preparation for the first advanced detector observing period. The MBTA pipeline is ready for the outset of the advanced detector era and the exciting prospects it will bring. (paper)

  13. Automatic cloud coverage assessment of Formosat-2 image

    Science.gov (United States)

    Hsu, Kuo-Hsien

    2011-11-01

    Formosat-2 satellite equips with the high-spatial-resolution (2m ground sampling distance) remote sensing instrument. It has been being operated on the daily-revisiting mission orbit by National Space organization (NSPO) of Taiwan since May 21 2004. NSPO has also serving as one of the ground receiving stations for daily processing the received Formosat- 2 images. The current cloud coverage assessment of Formosat-2 image for NSPO Image Processing System generally consists of two major steps. Firstly, an un-supervised K-means method is used for automatically estimating the cloud statistic of Formosat-2 image. Secondly, manual estimation of cloud coverage from Formosat-2 image is processed by manual examination. Apparently, a more accurate Automatic Cloud Coverage Assessment (ACCA) method certainly increases the efficiency of processing step 2 with a good prediction of cloud statistic. In this paper, mainly based on the research results from Chang et al, Irish, and Gotoh, we propose a modified Formosat-2 ACCA method which considered pre-processing and post-processing analysis. For pre-processing analysis, cloud statistic is determined by using un-supervised K-means classification, Sobel's method, Otsu's method, non-cloudy pixels reexamination, and cross-band filter method. Box-Counting fractal method is considered as a post-processing tool to double check the results of pre-processing analysis for increasing the efficiency of manual examination.

  14. Si(Li) X-ray detector

    International Nuclear Information System (INIS)

    Yuan Xianglin; Li Zhiyong; Hong Xiuse

    1990-08-01

    The fabrication technology of the 10∼80 mm 2 Si(Li) X-ray detectors are described and some problems concerning technology and measurement are discussed. The specifications of the detectors are shown as well. The Si(Li) X-ray detector is a kind of low energy X-ray detectors. Owing to very high energy resolution, fine linearity and high detection efficiency in the range of low energy X-rays, it is widely used in the fields of nuclear physics, medicine, geology and environmental protection, etc,. It is also a kernel component for the scanning electron microscope and X-ray fluorescence analysis systems

  15. Global yellow fever vaccination coverage from 1970 to 2016: an adjusted retrospective analysis

    OpenAIRE

    Shearer, FM; Moyes, CL; Pigott, DM; Marinho, F; Deshpande, A; Longbottom, J; Browne, AJ; Kraemer, MUG; O’Reilly, KM; Hombach, J; Yactayo, S; de Araújo, VEM; da Nόbrega, AA; Mosser, JF; Stanaway, JD

    2017-01-01

    Summary Background: Substantial outbreaks of yellow fever in Angola and Brazil in the past 2 years, combined with global shortages in vaccine stockpiles, highlight a pressing need to assess present control strategies. The aims of this study were to estimate global yellow fever vaccination coverage from 1970 through to 2016 at high spatial resolution and to calculate the number of individuals still requiring vaccination to reach population coverage thresholds for outbreak prevention. Methods: ...

  16. Constructing and Using Broad-coverage Lexical Resource for Enhancing Morphological Analysis of Arabic

    OpenAIRE

    Sawalha, M.; Atwell, E.S.

    2010-01-01

    Broad-coverage language resources which provide prior linguistic knowledge must improve the accuracy and the performance of NLP applications. We are constructing a broad-coverage lexical resource to improve the accuracy of morphological analyzers and part-of-speech taggers of Arabic text. Over the past 1200 years, many different kinds of Arabic language lexicons were constructed; these lexicons are different in ordering, size and aim or goal of construction. We collected 23 machine-readable l...

  17. The TORCH time-of-flight detector

    Energy Technology Data Exchange (ETDEWEB)

    Harnew, N., E-mail: Neville.Harnew@physics.ox.ac.uk [University of Oxford, Denys Wilkinson Building, 1 Keble Road, Oxford OX1 3RH (United Kingdom); Brook, N. [University College London, Department of Physics & Astronomy, Gower Street, London WC1E 6BT (United Kingdom); Castillo García, L. [CERN, PH Department, CH-1211 Geneva 23 (Switzerland); Laboratory for High Energy Physics, Ecole Polytechnique Fédérale de Lausanne, CH-1015 Lausanne (Switzerland); Cussans, D. [H.H. Wills Physics Laboratory, University of Bristol, Bristol BS8 1TL (United Kingdom); Föhl, K.; Forty, R.; Frei, C. [CERN, PH Department, CH-1211 Geneva 23 (Switzerland); Gao, R. [University of Oxford, Denys Wilkinson Building, 1 Keble Road, Oxford OX1 3RH (United Kingdom); Gys, T.; Piedigrossi, D. [CERN, PH Department, CH-1211 Geneva 23 (Switzerland); Rademacker, J.; Ros Garcia, A.; Dijk, M. van [H.H. Wills Physics Laboratory, University of Bristol, Bristol BS8 1TL (United Kingdom)

    2016-07-11

    The TORCH time-of-flight detector is being developed to provide particle identification between 2 and 10 GeV/c momentum over a flight distance of 10 m. TORCH is designed for large-area coverage, up to 30 m{sup 2}, and has a DIRC-like construction. The goal is to achieve a 15 ps time-of-flight resolution per incident particle by combining arrival times from multiple Cherenkov photons produced within quartz radiator plates of 10 mm thickness. A four-year R&D programme is underway with an industrial partner (Photek, UK) to produce 53×53 mm{sup 2} Micro-Channel Plate (MCP) detectors for the TORCH application. The MCP-PMT will provide a timing accuracy of 40 ps per photon and it will have a lifetime of up to at least 5 Ccm{sup −2} of integrated anode charge by utilizing an Atomic Layer Deposition (ALD) coating. The MCP will be read out using charge division with customised electronics incorporating the NINO chipset. Laboratory results on prototype MCPs are presented. The construction of a prototype TORCH module and its simulated performance are also described.

  18. Quantitative Characterization of Phosphor Detector for Fusion Plasmas; Caracterizacion Cuantitativa de Detectores Luminiscentes para Plasmas de Fusion

    Energy Technology Data Exchange (ETDEWEB)

    Baciero, A; Zurro, B; McCarthy, K J

    2004-07-01

    Experiments made to characterize phosphor screens with application as broadband radiation detectors, are described. Several radiation sources, covering the spectral range between the ultraviolet and X ray, were used. In addition, details are given of three original phosphor-screen-based detectors that were designed for use as broadband detectors in magnetically confined fusion devices. The first measurements obtained with these detectors in plasmas created in the TJ-II stellarator device are presented together with the analysis performed. (Author)

  19. High-performance DIRC detector for the future Electron Ion Collider experiment

    Science.gov (United States)

    Kalicy, G.; Allison, L.; Cao, T.; Dzhygadlo, R.; Hartlove, T.; Horn, T.; Hyde, C.; Ilieva, Y.; Nadel-Turonski, P.; Park, K.; Peters, K.; Schwarz, C.; Schwiening, J.; Stevens, J.; Xi, W.; Zorn, C.

    2018-04-01

    Excellent particle identification (PID) is an essential requirement for a future Electron-Ion Collider (EIC) detector. Identification of the hadrons in the final state is critical to study how different quark flavors contribute to nucleon properties. A detector based on the Detection of Internally Reflected Cherenkov light (DIRC) principle, with a radial size of only a few cm, is a perfect solution for those requirements. The R&D process performed by the EIC PID consortium (eRD14) is focused on designing a high-performance DIRC that would extend the momentum coverage well beyond the state-of-the-art, allowing 3 standard deviations or more separation of π/K up to 6 GeV/c, e/π up to 1.8 GeV/c, and p/K up to 10 GeV/c. A key component to reach such a performance is a special 3-layer compound lens. This article describes the status of the High-Performance DIRC R&D for the EIC detector, with a focus on the detailed Monte Carlo simulation results and performance tests of the 3-layer lens.

  20. Model analysis and experimental characterization of a microstrip vertex detector for a e+e- collider

    International Nuclear Information System (INIS)

    Walter, C.P.

    1989-09-01

    This thesis is constituted by several topics, apparently weakly correlated, but that are all addressed to improve the performances of the ALEPH microvertex detector both in the present version and in the upgraded one with JFET-CMOS electronics. A wide program of computer simulations about the upgraded JFET-CMOS version of the read-out electronics have been carried out to test its working principle and radiation hardness measurements have been performed on the prototypes of the same electronics to test its capability to stand the radiation environment foreseen in ALEPH. Extensive calculations of the capacitances in a microstrip detector are presented and their influence on the detector, both from the point of view of its noise performances and of the capacitive charge division method, has been analyzed theoretically, both through analytic calculations and numerical simulations; experimental measurements on the same relevant capacitances are discussed. Strictly connected to this point a computer code simulating the interaction of a minimum ionizing particle with the detector has been written and algorithms to determine the interaction point have been studied. This code has been later inserted in the Monte Carlo program of ALEPH. A point not strictly connected to ALEPH and still treated here is the analysis of the noise of two JFET devices, that is however interesting not as much for the results themselves, as for the analysis technique used that brought to identify noise sources that are usually difficult to detect and neglected. (orig.)

  1. Analysis of Current-mode Detectors For Resonance Detection In Neutron Optics Time Reversal Symmetry Experiment

    Science.gov (United States)

    Forbes, Grant; Noptrex Collaboration

    2017-09-01

    One of the most promising explanations for the observed matter-antimatter asymmetry in our universe is the search for new sources of time-reversal (T) symmetry violation. The current amount of violation seen in the kaon and B-meson systems is not sufficient to describe this asymmetry. The Neutron Optics Time Reversal Experiment Collaboration (NOPTREX) is a null test for T violation in polarized neutron transmission through a polarized 139La target. Due to the high neutron flux needed for this experiment, as well as the ability to effectively subtract background noise, a current-mode neutron detector that can resolve resonances at epithermal energies has been proposed. In order to ascertain if this detector design would meet the requirements for the eventual NOPTREX experiment, prototypical detectors were tested at the NOBORU beam at the Japan Proton Accelerator Research Complex (JPARC) facility. Resonances in In and Ta were measured and the collected data was analyzed. This presentation will describe the analysis process and the efficacy of the detectors will be discussed. Department of Energy under Contract DE-SC0008107, UGRAS Scholarship.

  2. Right and left support feet of the Central Barrel Yoke of the CMS Detector

    CERN Multimedia

    Franz Leher, DWE

    2000-01-01

    Fully loaded the Central Barrel will weigh 3000 tonnes. Those feet have tosupport this weight. Therefore they are made of 120 mm thick steel plates.To guarantee a maximum coverage for the muon detctor they will house a muon detector just benaeth the top plate. Weight of 1 foot is 35 tonnes.Its height is 3.5 m and it is 2.5 m large

  3. Detector simulation needs for detector designers

    International Nuclear Information System (INIS)

    Hanson, G.G.

    1987-11-01

    Computer simulation of the components of SSC detectors and of the complete detectors will be very important for the designs of the detectors. The ratio of events from interesting physics to events from background processes is very low, so detailed understanding of detector response to the backgrounds is needed. Any large detector for the SSC will be very complex and expensive and every effort must be made to design detectors which will have excellent performance and will not have to undergo major rebuilding. Some areas in which computer simulation is particularly needed are pattern recognition in tracking detectors and development of shower simulation code which can be trusted as an aid in the design and optimization of calorimeters, including their electron identification performance. Existing codes require too much computer time to be practical and need to be compared with test beam data at energies of several hundred GeV. Computer simulation of the processing of the data, including electronics response to the signals from the detector components, processing of the data by microprocessors on the detector, the trigger, and data acquisition will be required. In this report we discuss the detector simulation needs for detector designers

  4. Coverage Metrics for Model Checking

    Science.gov (United States)

    Penix, John; Visser, Willem; Norvig, Peter (Technical Monitor)

    2001-01-01

    When using model checking to verify programs in practice, it is not usually possible to achieve complete coverage of the system. In this position paper we describe ongoing research within the Automated Software Engineering group at NASA Ames on the use of test coverage metrics to measure partial coverage and provide heuristic guidance for program model checking. We are specifically interested in applying and developing coverage metrics for concurrent programs that might be used to support certification of next generation avionics software.

  5. Association of left subclavian artery coverage without revascularization and spinal cord ischemia in patients undergoing thoracic endovascular aortic repair: A Vascular Quality Initiative® analysis.

    Science.gov (United States)

    Teixeira, Pedro Gr; Woo, Karen; Beck, Adam W; Scali, Salvatore T; Weaver, Fred A

    2017-12-01

    Objectives Investigate the impact of left subclavian artery coverage without revascularization on spinal cord ischemia development in patients undergoing thoracic endovascular aortic repair. Methods The Vascular Quality Initiative thoracic endovascular aortic repair module (April 2011-July 2014) was analyzed. Patients undergoing left subclavian artery coverage were divided into two groups according to revascularization status. The association between left subclavian artery revascularization with the primary outcome of spinal cord ischemia and the secondary outcome of stroke was assessed with multivariable analysis adjusting for between-group baseline differences. Results The left subclavian artery was covered in 508 (24.6%) of the 2063 thoracic endovascular aortic repairs performed. Among patients with left subclavian artery coverage, 58.9% underwent revascularization. Spinal cord ischemia incidence was 12.1% in the group without revascularization compared to 8.5% in the group undergoing left subclavian artery revascularization (odds ratio (95%CI): 1.48(0.82-2.68), P = 0.189). Multivariable analysis adjustment identified an independent association between left subclavian artery coverage without revascularization and the incidence of spinal cord ischemia (adjusted odds ratio (95%CI): 2.29(1.03-5.14), P = 0.043). Although the incidence of stroke was also higher for the group with a covered and nonrevascularized left subclavian artery (12.1% versus 8.5%), this difference was not statistically significant after multivariable analysis (adjusted odds ratio (95%CI): 1.55(0.74-3.26), P = 0.244). Conclusion For patients undergoing left subclavian artery coverage during thoracic endovascular aortic repair, the addition of a revascularization procedure was associated with a significantly lower incidence of spinal cord ischemia.

  6. Duplicate Health Insurance Coverage: Determinants of Variation Across States

    OpenAIRE

    Luft, Harold S.; Maerki, Susan C.

    1982-01-01

    Although it is recognized that many people have duplicate private health insurance coverage, either through separate purchase or as health benefits in multi-earner families, there has been little analysis of the factors determining duplicate coverage rates. A new data source, the Survey of Income and Education, offers a comparison with the only previous source of state level data, the estimates from the Health Insurance Association of America. The R2 between the two sets is only .3 and certai...

  7. Time response measurements of LASL diagnostic detectors

    International Nuclear Information System (INIS)

    Hocker, L.P.

    1970-07-01

    The measurement and data analysis techniques developed under the Los Alamos Scientific Laboratory's detector improvement program were used to characterize the time and frequency response of selected LASL Compton, fluor-photodiode (NPD), and fluor-photomultiplier (NPM) diagnostic detectors. Data acquisition procedures and analysis methods presently in use are summarized, and detector time and frequency data obtained using the EG and G/AEC electron linear accelerator fast pulse (approximately 50 psec FWHM) as the incident radiation driving function are presented. (U.S.)

  8. Commercialization of Micro-fabrication of Antenna-Coupled Transition Edge Sensor Bolometer Detectors for Studies of the Cosmic Microwave Background

    Science.gov (United States)

    Suzuki, Aritoki; Bebek, Chris; Garcia-Sciveres, Maurice; Holland, Stephen; Kusaka, Akito; Lee, Adrian T.; Palaio, Nicholas; Roe, Natalie; Steinmetz, Leo

    2018-04-01

    We report on the development of commercially fabricated multichroic antenna-coupled transition edge sensor (TES) bolometer arrays for cosmic microwave background (CMB) polarimetry experiments. CMB polarimetry experiments have deployed instruments in stages. Stage II experiments deployed with O(1000) detectors and reported successful detection of B-mode (divergence-free) polarization pattern in the CMB. Stage III experiments have recently started observing with O(10,000) detectors with wider frequency coverage. A concept for a stage IV experiment, CMB-S4, is emerging to make a definitive measurement of CMB polarization from the ground with O(400,000) detectors. The orders of magnitude increase in detector count for CMB-S4 require a new approach in detector fabrication to increase fabrication throughput and reduce the cost. We report on collaborative efforts with two commercial micro-fabrication foundries to fabricate antenna-coupled TES bolometer detectors. The detector design is based on the sinuous antenna-coupled dichroic detector from the POLARBEAR-2 experiment. The TES bolometers showed the expected I-V response, and the RF performance agrees with the simulation. We will discuss the motivation, design consideration, fabrication processes, test results, and how industrial detector fabrication could be a path to fabricate hundreds of detector wafers for future CMB polarimetry experiments.

  9. MUON DETECTORS: RPC

    CERN Multimedia

    P. Paolucci

    2011-01-01

    RPC detector calibration, HV scan Thanks to the high LHC luminosity and to the corresponding high number of muons created in the first part of the 2011 the RPC community had, for the first time, the possibility to calibrate every single detector element (roll).The RPC steering committee provided the guidelines for both data-taking and data analysis and a dedicated task force worked from March to April on this specific issue. The main goal of the RPC calibration was to study the detector efficiency as a function of high-voltage working points, fit the obtained “plateau curve” with a sigmoid function and determine the “best” high-voltage working point of every single roll. On 18th and 19th March, we had eight runs at different voltages. On 27th March, the full analysis was completed, showing that 60% of the rolls had already a very good fit with an average efficiency greater than 93% in the plateau region. To improve the fit we decided to take three more runs (15th April...

  10. Electromechanically cooled germanium radiation detector system

    International Nuclear Information System (INIS)

    Lavietes, Anthony D.; Joseph Mauger, G.; Anderson, Eric H.

    1999-01-01

    We have successfully developed and fielded an electromechanically cooled germanium radiation detector (EMC-HPGe) at Lawrence Livermore National Laboratory (LLNL). This detector system was designed to provide optimum energy resolution, long lifetime, and extremely reliable operation for unattended and portable applications. For most analytical applications, high purity germanium (HPGe) detectors are the standard detectors of choice, providing an unsurpassed combination of high energy resolution performance and exceptional detection efficiency. Logistical difficulties associated with providing the required liquid nitrogen (LN) for cooling is the primary reason that these systems are found mainly in laboratories. The EMC-HPGe detector system described in this paper successfully provides HPGe detector performance in a portable instrument that allows for isotopic analysis in the field. It incorporates a unique active vibration control system that allows the use of a Sunpower Stirling cycle cryocooler unit without significant spectral degradation from microphonics. All standard isotopic analysis codes, including MGA and MGA++, GAMANL, GRPANL and MGAU, typically used with HPGe detectors can be used with this system with excellent results. Several national and international Safeguards organisations including the International Atomic Energy Agency (IAEA) and U.S. Department of Energy (DOE) have expressed interest in this system. The detector was combined with custom software and demonstrated as a rapid Field Radiometric Identification System (FRIS) for the U.S. Customs Service . The European Communities' Safeguards Directorate (EURATOM) is field-testing the first Safeguards prototype in their applications. The EMC-HPGe detector system design, recent applications, and results will be highlighted

  11. Fluorescence decay data analysis correcting for detector pulse pile-up at very high count rates

    Science.gov (United States)

    Patting, Matthias; Reisch, Paja; Sackrow, Marcus; Dowler, Rhys; Koenig, Marcelle; Wahl, Michael

    2018-03-01

    Using time-correlated single photon counting for the purpose of fluorescence lifetime measurements is usually limited in speed due to pile-up. With modern instrumentation, this limitation can be lifted significantly, but some artifacts due to frequent merging of closely spaced detector pulses (detector pulse pile-up) remain an issue to be addressed. We propose a data analysis method correcting for this type of artifact and the resulting systematic errors. It physically models the photon losses due to detector pulse pile-up and incorporates the loss in the decay fit model employed to obtain fluorescence lifetimes and relative amplitudes of the decay components. Comparison of results with and without this correction shows a significant reduction of systematic errors at count rates approaching the excitation rate. This allows quantitatively accurate fluorescence lifetime imaging at very high frame rates.

  12. CCTV Coverage Index Based on Surveillance Resolution and Its Evaluation Using 3D Spatial Analysis

    Directory of Open Access Journals (Sweden)

    Kyoungah Choi

    2015-09-01

    Full Text Available We propose a novel approach to evaluating how effectively a closed circuit television (CCTV system can monitor a targeted area. With 3D models of the target area and the camera parameters of the CCTV system, the approach produces surveillance coverage index, which is newly defined in this study as a quantitative measure for surveillance performance. This index indicates the proportion of the space being monitored with a sufficient resolution to the entire space of the target area. It is determined by computing surveillance resolution at every position and orientation, which indicates how closely a specific object can be monitored with a CCTV system. We present full mathematical derivation for the resolution, which depends on the location and orientation of the object as well as the geometric model of a camera. With the proposed approach, we quantitatively evaluated the surveillance coverage of a CCTV system in an underground parking area. Our evaluation process provided various quantitative-analysis results, compelling us to examine the design of the CCTV system prior to its installation and understand the surveillance capability of an existing CCTV system.

  13. Human papillomavirus (HPV) vaccine coverage achievements in low and middle-income countries 2007-2016.

    Science.gov (United States)

    Gallagher, Katherine E; Howard, Natasha; Kabakama, Severin; Mounier-Jack, Sandra; Burchett, Helen E D; LaMontagne, D Scott; Watson-Jones, Deborah

    2017-12-01

    Since 2007, HPV vaccine has been available to low and middle income countries (LAMIC) for small-scale 'demonstration projects', or national programmes. We analysed coverage achieved in HPV vaccine demonstration projects and national programmes that had completed at least 6 months of implementation between January 2007-2016. A mapping exercise identified 45 LAMICs with HPV vaccine delivery experience. Estimates of coverage and factors influencing coverage were obtained from 56 key informant interviews, a systematic published literature search of 5 databases that identified 61 relevant full texts and 188 solicited unpublished documents, including coverage surveys. Coverage achievements were analysed descriptively against country or project/programme characteristics. Heterogeneity in data, funder requirements, and project/programme design precluded multivariate analysis. Estimates of uptake, schedule completion rates and/or final dose coverage were available from 41 of 45 LAMICs included in the study. Only 17 estimates from 13 countries were from coverage surveys, most were administrative data. Final dose coverage estimates were all over 50% with most between 70% and 90%, and showed no trend over time. The majority of delivery strategies included schools as a vaccination venue. In countries with school enrolment rates below 90%, inclusion of strategies to reach out-of-school girls contributed to obtaining high coverage compared to school-only strategies. There was no correlation between final dose coverage and estimated recurrent financial costs of delivery from cost analyses. Coverage achieved during joint delivery of HPV vaccine combined with another intervention was variable with little/no evaluation of the correlates of success. This is the most comprehensive descriptive analysis of HPV vaccine coverage in LAMICs to date. It is possible to deliver HPV vaccine with excellent coverage in LAMICs. Further good quality data are needed from health facility based

  14. Uranium analysis by neutron induced fissionography method using solid state nuclear track detectors

    International Nuclear Information System (INIS)

    Akyuez, T.; Tretyakova, S. P.; Guezel, T.; Akyuz, S.

    1999-01-01

    In this study total twenty samples (eight reference materials and twelve sediment samples) were analysed for their uranium content which is in the range of 1-17 μg/g, by neutron induced fissionography (NIF) method using solid state nuclear track detectors (SSNTDs) in comparison with the results of neutron activation analysis (NAA), delayed neutron counting (DNC) technique or fluorometric method. It is found that NIF method using SSNTDs is very sensitive for analysis of uranium

  15. Uranium analysis by neutron induced fissionography method using solid state nuclear track detectors

    CERN Document Server

    Akyuez, T; Guezel, T; Akyuz, S

    1999-01-01

    In this study total twenty samples (eight reference materials and twelve sediment samples) were analysed for their uranium content which is in the range of 1-17 mu g/g, by neutron induced fissionography (NIF) method using solid state nuclear track detectors (SSNTDs) in comparison with the results of neutron activation analysis (NAA), delayed neutron counting (DNC) technique or fluorometric method. It is found that NIF method using SSNTDs is very sensitive for analysis of uranium.

  16. Fault-weighted quantification method of fault detection coverage through fault mode and effect analysis in digital I&C systems

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Jaehyun; Lee, Seung Jun, E-mail: sjlee420@unist.ac.kr; Jung, Wondea

    2017-05-15

    Highlights: • We developed the fault-weighted quantification method of fault detection coverage. • The method has been applied to specific digital reactor protection system. • The unavailability of the module had 20-times difference with the traditional method. • Several experimental tests will be effectively prioritized using this method. - Abstract: The one of the most outstanding features of a digital I&C system is the use of a fault-tolerant technique. With an awareness regarding the importance of thequantification of fault detection coverage of fault-tolerant techniques, several researches related to the fault injection method were developed and employed to quantify a fault detection coverage. In the fault injection method, each injected fault has a different importance because the frequency of realization of every injected fault is different. However, there have been no previous studies addressing the importance and weighting factor of each injected fault. In this work, a new method for allocating the weighting to each injected fault using the failure mode and effect analysis data was proposed. For application, the fault-weighted quantification method has also been applied to specific digital reactor protection system to quantify the fault detection coverage. One of the major findings in an application was that we may estimate the unavailability of the specific module in digital I&C systems about 20-times smaller than real value when we use a traditional method. The other finding was that we can also classify the importance of the experimental case. Therefore, this method is expected to not only suggest an accurate quantification procedure of fault-detection coverage by weighting the injected faults, but to also contribute to an effective fault injection experiment by sorting the importance of the failure categories.

  17. 5 CFR 890.1106 - Coverage.

    Science.gov (United States)

    2010-01-01

    ... family member is an individual whose relationship to the enrollee meets the requirements of 5 U.S.C. 8901... EMPLOYEES HEALTH BENEFITS PROGRAM Temporary Continuation of Coverage § 890.1106 Coverage. (a) Type of enrollment. An individual who enrolls under this subpart may elect coverage for self alone or self and family...

  18. (Li) detector characteristics on the accuracy in X-ray analysis using the

    African Journals Online (AJOL)

    A study has been carried out to show how variations in Si(Li) detector characteristics affect the accuracy of X-ray spectra evaluation. The detector characteristics investigated are Be window thickness, Au layer, Si dead layer and Si Detector Sensitive volume. For each of the detector parameters, different thickness values ...

  19. 29 CFR 801.3 - Coverage.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 3 2010-07-01 2010-07-01 false Coverage. 801.3 Section 801.3 Labor Regulations Relating to Labor (Continued) WAGE AND HOUR DIVISION, DEPARTMENT OF LABOR OTHER LAWS APPLICATION OF THE EMPLOYEE POLYGRAPH PROTECTION ACT OF 1988 General § 801.3 Coverage. (a) The coverage of the Act extends to “any...

  20. Building high-coverage monolayers of covalently bound magnetic nanoparticles

    Energy Technology Data Exchange (ETDEWEB)

    Williams, Mackenzie G.; Teplyakov, Andrew V., E-mail: andrewt@udel.edu

    2016-12-01

    Graphical abstract: - Highlights: • A method for forming a layer of covalently bound nanoparticles is offered. • A nearly perfect monolayer of covalently bound magnetic nanoparticles was formed on gold. • Spectroscopic techniques confirmed covalent binding by the “click” reaction. • The influence of the functionalization scheme on surface coverage was investigated. - Abstract: This work presents an approach for producing a high-coverage single monolayer of magnetic nanoparticles using “click chemistry” between complementarily functionalized nanoparticles and a flat substrate. This method highlights essential aspects of the functionalization scheme for substrate surface and nanoparticles to produce exceptionally high surface coverage without sacrificing selectivity or control over the layer produced. The deposition of one single layer of magnetic particles without agglomeration, over a large area, with a nearly 100% coverage is confirmed by electron microscopy. Spectroscopic techniques, supplemented by computational predictions, are used to interrogate the chemistry of the attachment and to confirm covalent binding, rather than attachment through self-assembly or weak van der Waals bonding. Density functional theory calculations for the surface intermediate of this copper-catalyzed process provide mechanistic insight into the effects of the functionalization scheme on surface coverage. Based on this analysis, it appears that steric limitations of the intermediate structure affect nanoparticle coverage on a flat solid substrate; however, this can be overcome by designing a functionalization scheme in such a way that the copper-based intermediate is formed on the spherical nanoparticles instead. This observation can be carried over to other approaches for creating highly controlled single- or multilayered nanostructures of a wide range of materials to result in high coverage and possibly, conformal filling.

  1. Coverage dependent molecular assembly of anthraquinone on Au(111)

    Science.gov (United States)

    DeLoach, Andrew S.; Conrad, Brad R.; Einstein, T. L.; Dougherty, Daniel B.

    2017-11-01

    A scanning tunneling microscopy study of anthraquinone (AQ) on the Au(111) surface shows that the molecules self-assemble into several structures depending on the local surface coverage. At high coverages, a close-packed saturated monolayer is observed, while at low coverages, mobile surface molecules coexist with stable chiral hexamer clusters. At intermediate coverages, a disordered 2D porous network interlinking close-packed islands is observed in contrast to the giant honeycomb networks observed for the same molecule on Cu(111). This difference verifies the predicted extreme sensitivity [J. Wyrick et al., Nano Lett. 11, 2944 (2011)] of the pore network to small changes in the surface electronic structure. Quantitative analysis of the 2D pore network reveals that the areas of the vacancy islands are distributed log-normally. Log-normal distributions are typically associated with the product of random variables (multiplicative noise), and we propose that the distribution of pore sizes for AQ on Au(111) originates from random linear rate constants for molecules to either desorb from the surface or detach from the region of a nucleated pore.

  2. Identifying the critical success factors in the coverage of low vision services using the classification analysis and regression tree methodology.

    Science.gov (United States)

    Chiang, Peggy Pei-Chia; Xie, Jing; Keeffe, Jill Elizabeth

    2011-04-25

    To identify the critical success factors (CSF) associated with coverage of low vision services. Data were collected from a survey distributed to Vision 2020 contacts, government, and non-government organizations (NGOs) in 195 countries. The Classification and Regression Tree Analysis (CART) was used to identify the critical success factors of low vision service coverage. Independent variables were sourced from the survey: policies, epidemiology, provision of services, equipment and infrastructure, barriers to services, human resources, and monitoring and evaluation. Socioeconomic and demographic independent variables: health expenditure, population statistics, development status, and human resources in general, were sourced from the World Health Organization (WHO), World Bank, and the United Nations (UN). The findings identified that having >50% of children obtaining devices when prescribed (χ(2) = 44; P 3 rehabilitation workers per 10 million of population (χ(2) = 4.50; P = 0.034), higher percentage of population urbanized (χ(2) = 14.54; P = 0.002), a level of private investment (χ(2) = 14.55; P = 0.015), and being fully funded by government (χ(2) = 6.02; P = 0.014), are critical success factors associated with coverage of low vision services. This study identified the most important predictors for countries with better low vision coverage. The CART is a useful and suitable methodology in survey research and is a novel way to simplify a complex global public health issue in eye care.

  3. Detector materials: germanium and silicon

    International Nuclear Information System (INIS)

    Haller, E.E.

    1981-11-01

    This article is a summary of a short course lecture given in conjunction with the 1981 Nuclear Science Symposium. The basic physical properties of elemental semiconductors are reviewed. The interaction of energetic radiation with matter is discussed in order to develop a feeling for the appropriate semiconductor detector dimensions. The extremely low net dopant concentrations which are required are derived directly from the detector dimensions. A survey of the more recent techniques which have been developed for the analysis of detector grade semiconductor single crystals is presented

  4. Monitoring intervention coverage in the context of universal health coverage.

    Directory of Open Access Journals (Sweden)

    Ties Boerma

    2014-09-01

    Full Text Available Monitoring universal health coverage (UHC focuses on information on health intervention coverage and financial protection. This paper addresses monitoring intervention coverage, related to the full spectrum of UHC, including health promotion and disease prevention, treatment, rehabilitation, and palliation. A comprehensive core set of indicators most relevant to the country situation should be monitored on a regular basis as part of health progress and systems performance assessment for all countries. UHC monitoring should be embedded in a broad results framework for the country health system, but focus on indicators related to the coverage of interventions that most directly reflect the results of UHC investments and strategies in each country. A set of tracer coverage indicators can be selected, divided into two groups-promotion/prevention, and treatment/care-as illustrated in this paper. Disaggregation of the indicators by the main equity stratifiers is critical to monitor progress in all population groups. Targets need to be set in accordance with baselines, historical rate of progress, and measurement considerations. Critical measurement gaps also exist, especially for treatment indicators, covering issues such as mental health, injuries, chronic conditions, surgical interventions, rehabilitation, and palliation. Consequently, further research and proxy indicators need to be used in the interim. Ideally, indicators should include a quality of intervention dimension. For some interventions, use of a single indicator is feasible, such as management of hypertension; but in many areas additional indicators are needed to capture quality of service provision. The monitoring of UHC has significant implications for health information systems. Major data gaps will need to be filled. At a minimum, countries will need to administer regular household health surveys with biological and clinical data collection. Countries will also need to improve the

  5. Spectral Analysis Method of Plastic Scintillator-based Radiation Detector against Nuclear/Radiological Terrorism

    International Nuclear Information System (INIS)

    Kwak, Sung-Woo; Yoo, Ho-Sik; Jang, Sung Soon; Kim, Jung-Soo; Yoon, Wan-Ki

    2008-01-01

    In these days, the threats relating to nuclear or radioactive materials have become a matter of internationally increased grave concern. A plastic scintillation detector in radiation portal monitoring (RPM) application has been used to detect radioactive sources in steel scrap entering reprocessing facilities, and to detect illicit transport of radioactive material across border ports-of-entry. The detection systems for RPM application usually are large and can not easily be moved to a different location. For some situations, an inconspicuous and mobile system for the radioactive or nuclear material during road transport is needed. The mobile radiation detection system has employed a NaI- based radiation detector to detect and identify the material hidden in vehicle. There are some operational constraints - short measuring time, weak activity due to heavy shield of illegal source, long distance - of inspection system in such nuclear security applications. Due to these constraints, large area sensor is required to maximize its sensitivity. Large NaI material, however, is extremely expensive. In designing a radiation detector for prevention of illicit trafficking of nuclear or radioactive materials, the trade-off should be carefully optimized between performance and cost in order to achieve cost-effective inspection system. For the cost-effective mobile radiation detection system, this paper describes new spectral analysis method to use the crude spectroscopic information available from a plastic detector to discriminate other man-made radiation source from NORM

  6. Sandwich veto detector at COMPASS experiment

    International Nuclear Information System (INIS)

    Sarkar, S.; Dasgupta, S.S.; Calcutta-COMPASS group

    2010-01-01

    This paper presents the newly build Sandwich Detector for 190 GeV hadron run of COMPASS Experiment at CERN. The technical details and the testing procedures are included to highlight the physics objective of the installation. Single electron detection techniques has been developed and used to scale the performance of the detector. This analysis can predict the number of single electrons per MIP at the scintillation detector. (author)

  7. Impact of conflict on infant immunisation coverage in Afghanistan: a countrywide study 2000–2003

    Directory of Open Access Journals (Sweden)

    Seino Kaoruko

    2007-06-01

    Full Text Available Abstract Background Infant immunisation is an effective public health intervention to reduce the morbidity and mortality of vaccine preventable diseases. However, some developing countries fail to achieve desirable vaccination coverage; Afghanistan is one such country. The present study was performed to evaluate the progress and variation in infant immunisation coverage by district and region in Afghanistan and to assess the impact of conflict and resource availability on immunisation coverage. Results This study analysed reports of infant immunisation from 331 districts across 7 regions of Afghanistan between 2000 and 2003. Geographic information system (GIS analysis was used to visualise the distribution of immunisation coverage in districts and to identify geographic inequalities in the process of improvement of infant immunisation coverage. The number of districts reporting immunisation coverage increased substantially during the four years of the study. Progress in Bacillus Calmette-Guerin (BCG immunisation coverage was observed in all 7 regions, although satisfactory coverage of 80% remained unequally distributed. Progress in the third dose of Diphtheria-Pertussis-Tetanus (DPT3 immunisation differed among regions, in addition to the unequal distribution of immunisation coverage in 2000. The results of multivariate logistic regression analysis indicated a significant negative association between lack of security in the region and achievement of 80% coverage of immunisation regardless of available resources for immunisation, while resource availability showed no relation to immunisation coverage. Conclusion Although progress was observed in all 7 regions, geographic inequalities in these improvements remain a cause for concern. The results of the present study indicated that security within a country is an important factor for affecting the delivery of immunisation services.

  8. Analysis on coverage ability of BeiDou navigation satellite system for manned spacecraft

    Science.gov (United States)

    Zhao, Sihao; Yao, Zheng; Zhuang, Xuebin; Lu, Mingquan

    2014-12-01

    To investigate the service ability of the BeiDou Navigation Satellite System (BDS) for manned spacecraft, both the current regional and the future-planned global constellations of BDS are introduced and simulated. The orbital parameters of the International Space Station and China's Tiangong-1 spacelab are used to create the simulation scenario and evaluate the performance of the BDS constellations. The number of visible satellites and the position dilution (PDOP) of precision at the spacecraft-based receiver are evaluated. Simulation and analysis show quantitative results on the coverage ability and time percentages of both the current BDS regional and future global constellations for manned-space orbits which can be a guideline to the applications and mission design of BDS receivers on manned spacecraft.

  9. Toxic Compounds Analysis With High Performance Liquid Chromatography Detected By Electro Chemical Detector (Ecd)

    OpenAIRE

    Hideharu Shintaniq

    2014-01-01

    The principal area of application of high performance liquid chromatography-electrochemical detector (HPLC-ECD) has been in the analysis of naturally-occurring analytes, such as catecholamines, and pharmaceuticals in biological samples, HPLC-ECD has also applied to the analysis of pesticides and other analytes of interest to the toxicologist. In this paper, toxic area is described. In these, ammatoxins, aromatic amine, nitro-compounds, algal toxins, fungal toxins, pesticides, veterinary drug ...

  10. A comparison of genotyping-by-sequencing analysis methods on low-coverage crop datasets shows advantages of a new workflow, GB-eaSy.

    Science.gov (United States)

    Wickland, Daniel P; Battu, Gopal; Hudson, Karen A; Diers, Brian W; Hudson, Matthew E

    2017-12-28

    Genotyping-by-sequencing (GBS), a method to identify genetic variants and quickly genotype samples, reduces genome complexity by using restriction enzymes to divide the genome into fragments whose ends are sequenced on short-read sequencing platforms. While cost-effective, this method produces extensive missing data and requires complex bioinformatics analysis. GBS is most commonly used on crop plant genomes, and because crop plants have highly variable ploidy and repeat content, the performance of GBS analysis software can vary by target organism. Here we focus our analysis on soybean, a polyploid crop with a highly duplicated genome, relatively little public GBS data and few dedicated tools. We compared the performance of five GBS pipelines using low-coverage Illumina sequence data from three soybean populations. To address issues identified with existing methods, we developed GB-eaSy, a GBS bioinformatics workflow that incorporates widely used genomics tools, parallelization and automation to increase the accuracy and accessibility of GBS data analysis. Compared to other GBS pipelines, GB-eaSy rapidly and accurately identified the greatest number of SNPs, with SNP calls closely concordant with whole-genome sequencing of selected lines. Across all five GBS analysis platforms, SNP calls showed unexpectedly low convergence but generally high accuracy, indicating that the workflows arrived at largely complementary sets of valid SNP calls on the low-coverage data analyzed. We show that GB-eaSy is approximately as good as, or better than, other leading software solutions in the accuracy, yield and missing data fraction of variant calling, as tested on low-coverage genomic data from soybean. It also performs well relative to other solutions in terms of the run time and disk space required. In addition, GB-eaSy is built from existing open-source, modular software packages that are regularly updated and commonly used, making it straightforward to install and maintain

  11. Analysis of the Science and Technology Narrative within Organ Donation and Transplantation Coverage in Canadian Newspapers

    Directory of Open Access Journals (Sweden)

    Jennifer Cheung

    2015-04-01

    Full Text Available Organ failure is one cause of death. Advancements in scientific research and technological development made organ transplantation possible and continue to find better ways to substitute failed organs with other organs of biological origin or artificial organs. Media, including newspapers, are one source of information for the public. The purpose of this study was to examine to what extent and how science and technology research and development are covered in the organ transplantation and organ donation (ODOT coverage of n = 300 Canadian newspapers, including the two Canadian newspapers with national reach (The Globe and Mail, National Post. The study generated qualitative and quantitative data addressing the following issues: (1 which scientific and technological developments are mentioned in the ODOT coverage; and (2 what issues are mentioned in the coverage of scientific and technological advancements linked to ODOT. We found little to no coverage of many technological and scientific advancements evident in academic and grey literature covering ODOT, and we found little engagement with social and ethical issues already raised about these advancements in the literature. The only area we found to be covered to a broader extent was xenotransplantation, although the coverage stopped after 2002. We argue that the newspaper coverage of ODOT under reports scientific and technological advancements related to ODOT and the issues these advancements might raise.

  12. A Max-Flow Based Algorithm for Connected Target Coverage with Probabilistic Sensors

    Directory of Open Access Journals (Sweden)

    Anxing Shan

    2017-05-01

    Full Text Available Coverage is a fundamental issue in the research field of wireless sensor networks (WSNs. Connected target coverage discusses the sensor placement to guarantee the needs of both coverage and connectivity. Existing works largely leverage on the Boolean disk model, which is only a coarse approximation to the practical sensing model. In this paper, we focus on the connected target coverage issue based on the probabilistic sensing model, which can characterize the quality of coverage more accurately. In the probabilistic sensing model, sensors are only be able to detect a target with certain probability. We study the collaborative detection probability of target under multiple sensors. Armed with the analysis of collaborative detection probability, we further formulate the minimum ϵ-connected target coverage problem, aiming to minimize the number of sensors satisfying the requirements of both coverage and connectivity. We map it into a flow graph and present an approximation algorithm called the minimum vertices maximum flow algorithm (MVMFA with provable time complex and approximation ratios. To evaluate our design, we analyze the performance of MVMFA theoretically and also conduct extensive simulation studies to demonstrate the effectiveness of our proposed algorithm.

  13. Monitoring the mechanical vibration of in-core detector tubes and fuel channels via ICFD noise analysis

    International Nuclear Information System (INIS)

    Glockler, O.; Cooke, D.F.; Czuppon, G.J.; Kapoor, K.K.

    2000-01-01

    Vibrations of core internals are regularly monitored in the CANDU nuclear generating stations of Ontario Power Generation (OPG) via the noise analysis of in-core flux detectors (ICFDs). Voltage signals of standard station instrumentation are recorded by portable multi-channel high-speed high-resolution data acquisition systems, then statistical parameters are derived from the multi-channel time series measurements. Reactor noise analysis is a non-intrusive statistical technique regularly used in system surveillance, diagnostics and in actual operational I and C problems. It utilizes the dynamic information carried by the small fluctuations (noise) of station signals measured around their mean values during steady-state operation. The present paper discusses specific results related to the flow-induced mechanical vibrations of detector tubes and fuel channels. (author)

  14. Neutron and X-ray Detectors

    Energy Technology Data Exchange (ETDEWEB)

    Carini, Gabriella [SLAC National Accelerator Lab., Menlo Park, CA (United States); Denes, Peter [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Gruener, Sol [Cornell Univ., Ithaca, NY (United States); Lessner, Elianne [Dept. of Energy (DOE), Washington DC (United States). Office of Science Office of Basic Energy Sciences

    2012-08-01

    The Basic Energy Sciences (BES) X-ray and neutron user facilities attract more than 12,000 researchers each year to perform cutting-edge science at these state-of-the-art sources. While impressive breakthroughs in X-ray and neutron sources give us the powerful illumination needed to peer into the nano- to mesoscale world, a stumbling block continues to be the distinct lag in detector development, which is slowing progress toward data collection and analysis. Urgently needed detector improvements would reveal chemical composition and bonding in 3-D and in real time, allow researchers to watch “movies” of essential life processes as they happen, and make much more efficient use of every X-ray and neutron produced by the source The immense scientific potential that will come from better detectors has triggered worldwide activity in this area. Europe in particular has made impressive strides, outpacing the United States on several fronts. Maintaining a vital U.S. leadership in this key research endeavor will require targeted investments in detector R&D and infrastructure. To clarify the gap between detector development and source advances, and to identify opportunities to maximize the scientific impact of BES user facilities, a workshop on Neutron and X-ray Detectors was held August 1-3, 2012, in Gaithersburg, Maryland. Participants from universities, national laboratories, and commercial organizations from the United States and around the globe participated in plenary sessions, breakout groups, and joint open-discussion summary sessions. Sources have become immensely more powerful and are now brighter (more particles focused onto the sample per second) and more precise (higher spatial, spectral, and temporal resolution). To fully utilize these source advances, detectors must become faster, more efficient, and more discriminating. In supporting the mission of today’s cutting-edge neutron and X-ray sources, the workshop identified six detector research challenges

  15. [Quantification of acetabular coverage in normal adult].

    Science.gov (United States)

    Lin, R M; Yang, C Y; Yu, C Y; Yang, C R; Chang, G L; Chou, Y L

    1991-03-01

    Quantification of acetabular coverage is important and can be expressed by superimposition of cartilage tracings on the maximum cross-sectional area of the femoral head. A practical Autolisp program on PC AutoCAD has been developed by us to quantify the acetabular coverage through numerical expression of the images of computed tomography. Thirty adults (60 hips) with normal center-edge angle and acetabular index in plain X ray were randomly selected for serial drops. These slices were prepared with a fixed coordination and in continuous sections of 5 mm in thickness. The contours of the cartilage of each section were digitized into a PC computer and processed by AutoCAD programs to quantify and characterize the acetabular coverage of normal and dysplastic adult hips. We found that a total coverage ratio of greater than 80%, an anterior coverage ratio of greater than 75% and a posterior coverage ratio of greater than 80% can be categorized in a normal group. Polar edge distance is a good indicator for the evaluation of preoperative and postoperative coverage conditions. For standardization and evaluation of acetabular coverage, the most suitable parameters are the total coverage ratio, anterior coverage ratio, posterior coverage ratio and polar edge distance. However, medial coverage and lateral coverage ratios are indispensable in cases of dysplastic hip because variations between them are so great that acetabuloplasty may be impossible. This program can also be used to classify precisely the type of dysplastic hip.

  16. Fast timing readout for silicon strip detectors

    International Nuclear Information System (INIS)

    Jhingan, A.; Saneesh, N.; Kumar, M.

    2016-01-01

    The development and performance of a 16 channel hybrid fast timing amplifier (FTA), for extracting timing information from silicon strip detectors (SSD), is described. The FTA will be used in a time of flight (TOF) measurement, in which one SSD is used to obtain the ion velocity (A) as well as the energy information of a scattered particle. The TOF information with a thin transmission SSD, acting as ΔE detector (Z) in a detector telescope, will provide a unique detection system for the identification of reaction products in the slowed down beam campaign of low energy branch (LEB) at NUSTAR-FAIR. Such a system will also provide large solid angle coverage with ~ 100% detection efficiency, and adequate segmentation for angular information. A good timing resolution (≤ 100 ps) enables to have shorter flight paths, thus a closely packed 4π array should be feasible. Preamplifiers for energy readout in SSD are easily available. A major constraint with SSDs is the missing high density multichannel preamplifiers which can provide both fast timing as well as energy. Provision of both timing and energy processing, generally makes circuit bulky, with higher power consumption, which may not be suitable in SSD arrays. In case of DSSSD, the problem was overcome by using timing from one side and energy from the other side. A custom designed 16 channel FTA has been developed for DSSSD design W from Micron Semiconductors, UK

  17. Cooperative Cloud Service Aware Mobile Internet Coverage Connectivity Guarantee Protocol Based on Sensor Opportunistic Coverage Mechanism

    Directory of Open Access Journals (Sweden)

    Qin Qin

    2015-01-01

    Full Text Available In order to improve the Internet coverage ratio and provide connectivity guarantee, based on sensor opportunistic coverage mechanism and cooperative cloud service, we proposed the coverage connectivity guarantee protocol for mobile Internet. In this scheme, based on the opportunistic covering rules, the network coverage algorithm of high reliability and real-time security was achieved by using the opportunity of sensor nodes and the Internet mobile node. Then, the cloud service business support platform is created based on the Internet application service management capabilities and wireless sensor network communication service capabilities, which is the architecture of the cloud support layer. The cooperative cloud service aware model was proposed. Finally, we proposed the mobile Internet coverage connectivity guarantee protocol. The results of experiments demonstrate that the proposed algorithm has excellent performance, in terms of the security of the Internet and the stability, as well as coverage connectivity ability.

  18. Global analysis of cloud field coverage and radiative properties, using morphological methods and MODIS observations

    Directory of Open Access Journals (Sweden)

    R. Z. Bar-Or

    2011-01-01

    Full Text Available The recently recognized continuous transition zone between detectable clouds and cloud-free atmosphere ("the twilight zone" is affected by undetectable clouds and humidified aerosol. In this study, we suggest to distinguish cloud fields (including the detectable clouds and the surrounding twilight zone from cloud-free areas, which are not affected by clouds. For this classification, a robust and simple-to-implement cloud field masking algorithm which uses only the spatial distribution of clouds, is presented in detail. A global analysis, estimating Earth's cloud field coverage (50° S–50° N for 28 July 2008, using the Moderate Resolution Imaging Spectroradiometer (MODIS data, finds that while the declared cloud fraction is 51%, the global cloud field coverage reaches 88%. The results reveal the low likelihood for finding a cloud-free pixel and suggest that this likelihood may decrease as the pixel size becomes larger. A global latitudinal analysis of cloud fields finds that unlike oceans, which are more uniformly covered by cloud fields, land areas located under the subsidence zones of the Hadley cell (the desert belts, contain proper areas for investigating cloud-free atmosphere as there is 40–80% probability to detect clear sky over them. Usually these golden-pixels, with higher likelihood to be free of clouds, are over deserts. Independent global statistical analysis, using MODIS aerosol and cloud products, reveals a sharp exponential decay of the global mean aerosol optical depth (AOD as a function of the distance from the nearest detectable cloud, both above ocean and land. Similar statistical analysis finds an exponential growth of mean aerosol fine-mode fraction (FMF over oceans when the distance from the nearest cloud increases. A 30 km scale break clearly appears in several analyses here, suggesting this is a typical natural scale of cloud fields. This work shows different microphysical and optical properties of cloud fields

  19. Neutrino induced events in the MINOS detectors

    International Nuclear Information System (INIS)

    Litchfield, Reuben Phillip

    2008-01-01

    The MINOS experiment is designed to study neutrino oscillations. It uses an accelerator generated beam of neutrinos and two detectors, the smaller at a distance of 1km and the larger at 735 km. By comparing the spectrum and flavour composition of the beam at the two detectors precise determinations of the oscillation parameters are possible. This thesis concentrates on the analysis of data from the larger Far Detector. By studying the spectrum of neutral current events it is possible to look for evidence of non-interacting 'sterile' neutrinos. The thesis describes how events are selected for this analysis, and a method for discriminating between charged current and neutral current events. The systematic uncertainties resulting from these cuts are evaluated. Several techniques for using Near Detector data to eliminate systematic uncertainties in the predicted Far Detector spectrum are compared. An oscillation analysis, based on the first year of MINOS data, uses the selected events to make a measurement of f s , the fraction of unseen neutrinos that are sterile. The measured value is f s = 0.07 +0.32 at 68%C.L., and is consistent with the standard three-neutrino picture, which has no sterile neutrino

  20. Simulation and real-time analysis of pulse shapes from segmented HPGe-detectors

    Energy Technology Data Exchange (ETDEWEB)

    Schlarb, Michael Christian

    2009-11-17

    The capabilities of future HPGe arrays consisting of highly segmented detectors, like AGATA will depend heavily on the performance of {gamma}-ray tracking. The most crucial component in the whole concept is the pulse shape analysis (PSA). The working principle of PSA is to compare the experimental signal shape with signals available from a basis set with known interaction locations. The efficiency of the tracking algorithm hinges on the ability of the PSA to reconstruct the interaction locations accurately, especially for multiple {gamma}-interactions. Given the size of the arrays the PSA algorithm must be run in a real-time environment. A prerequisite to a successful PSA is an accurate knowledge of the detectors response. Making a full coincidence scan of a single AGATA detector, however takes between two and three months, which is too long to produce an experimental signal basis for all detector elements. A straight forward possibility is to use a precise simulation of the detector and to provide a basis of simulated signals. For this purpose the Java Agata Signal Simulation (JASS) was developed in the course of this thesis. The geometry of the detector is given with numerical precision and models describing the anisotropic mobilities of the charge carriers in germanium were taken from the literature. The pulse shapes of the transient and net-charge signals are calculated using weighting potentials on a finite grid. Special care was taken that the interpolation routine not only reproduces the weighting potentials precisely in the highly varying areas of the segment boundaries but also that its performance is independent of the location within the detector. Finally data from a coincidence scan and a pencil beam experiment were used to verify JASS. The experimental signals are reproduced accurately by the simulation. Pulse Shape Analysis (PSA) reconstructs the positions of the individual interactions and the corresponding energy deposits within the detector. This

  1. Simulation and real-time analysis of pulse shapes from segmented HPGe-detectors

    International Nuclear Information System (INIS)

    Schlarb, Michael Christian

    2009-01-01

    The capabilities of future HPGe arrays consisting of highly segmented detectors, like AGATA will depend heavily on the performance of γ-ray tracking. The most crucial component in the whole concept is the pulse shape analysis (PSA). The working principle of PSA is to compare the experimental signal shape with signals available from a basis set with known interaction locations. The efficiency of the tracking algorithm hinges on the ability of the PSA to reconstruct the interaction locations accurately, especially for multiple γ-interactions. Given the size of the arrays the PSA algorithm must be run in a real-time environment. A prerequisite to a successful PSA is an accurate knowledge of the detectors response. Making a full coincidence scan of a single AGATA detector, however takes between two and three months, which is too long to produce an experimental signal basis for all detector elements. A straight forward possibility is to use a precise simulation of the detector and to provide a basis of simulated signals. For this purpose the Java Agata Signal Simulation (JASS) was developed in the course of this thesis. The geometry of the detector is given with numerical precision and models describing the anisotropic mobilities of the charge carriers in germanium were taken from the literature. The pulse shapes of the transient and net-charge signals are calculated using weighting potentials on a finite grid. Special care was taken that the interpolation routine not only reproduces the weighting potentials precisely in the highly varying areas of the segment boundaries but also that its performance is independent of the location within the detector. Finally data from a coincidence scan and a pencil beam experiment were used to verify JASS. The experimental signals are reproduced accurately by the simulation. Pulse Shape Analysis (PSA) reconstructs the positions of the individual interactions and the corresponding energy deposits within the detector. This is

  2. A Negative Selection Algorithm Based on Hierarchical Clustering of Self Set and its Application in Anomaly Detection

    Directory of Open Access Journals (Sweden)

    Wen Chen

    2011-08-01

    Full Text Available A negative selection algorithm based on the hierarchical clustering of self set HC-RNSA is introduced in this paper. Several strategies are applied to improve the algorithm performance. First, the self data set is replaced by the self cluster centers to compare with the detector candidates in each cluster level. As the number of self clusters is much less than the self set size, the detector generation efficiency is improved. Second, during the detector generation process, the detector candidates are restricted to the lower coverage space to reduce detector redundancy. In the article, the problem that the distances between antigens coverage to a constant value in the high dimensional space is analyzed, accordingly the Principle Component Analysis (PCA method is used to reduce the data dimension, and the fractional distance function is employed to enhance the distinctiveness between the self and non-self antigens. The detector generation procedure is terminated when the expected non-self coverage is reached. The theory analysis and experimental results demonstrate that the detection rate of HC-RNSA is higher than that of the traditional negative selection algorithms while the false alarm rate and time cost are reduced.

  3. Determination of the response function for the Portsmouth Gaseous Diffusion Plant criticality accident alarm system neutron detectors

    International Nuclear Information System (INIS)

    Tayloe, R.W. Jr.; Brown, A.S.; Dobelbower, M.C.; Woollard, J.E.

    1997-03-01

    Neutron-sensitive radiation detectors are used in the Portsmouth Gaseous Diffusion Plant's (PORTS) criticality accident alarm system (CAAS). The CAAS is composed of numerous detectors, electronics, and logic units. It uses a telemetry system to sound building evacuation horns and to provide remote alarm status in a central control facility. The ANSI Standard for a CAAS uses a free-in-air dose rate to define the detection criteria for a minimum accident-of-concern. Previously, the free-in-air absorbed dose rate from neutrons was used for determining the areal coverge of criticality detection within PORTS buildings handling fissile materials. However, the free-in-air dose rate does not accurately reflect the response of the neutron detectors in use at PORTS. Because the cost of placing additional CAAS detectors in areas of questionable coverage (based on a free-in-air absorbed dose rate) is high, the actual response function for the CAAS neutron detectors was determined. This report, which is organized into three major sections, discusses how the actual response function for the PORTS CAAS neutron detectors was determined. The CAAS neutron detectors are described in Section 2. The model of the detector system developed to facilitate calculation of the response function is discussed in Section 3. The results of the calculations, including confirmatory measurements with neutron sources, are given in Section 4

  4. Radiation detectors

    International Nuclear Information System (INIS)

    2013-01-01

    This sixth chapter presents the operational principles of the radiation detectors; detection using photographic emulsions; thermoluminescent detectors; gas detectors; scintillation detectors; liquid scintillation detectors; detectors using semiconductor materials; calibration of detectors; Bragg-Gray theory; measurement chain and uncertainties associated to measurements

  5. Radiation damage in silicon. Defect analysis and detector properties

    Energy Technology Data Exchange (ETDEWEB)

    Hoenniger, F.

    2008-01-15

    Silicon microstrip and pixel detectors are vital sensor-components as particle tracking detectors for present as well as future high-energy physics (HEP) experiments. All experiments at the large Hadron Collider (LHC) are equipped with such detectors. Also for experiments after the upgrade of the LHC (the so-called Super-LHC), with its ten times higher luminosity, or the planned International Linear Collider (ILC) silicon tracking detectors are forseen. Close to the interaction region these detectors have to face harsh radiation fields with intensities above the presently tolerable level. defect engineering of the used material, e. g. oxygen enrichment of high resistivity float zone silicon and growing of thin low resistivityepitaxial layers on Czochralski silicon substrates has been established to improve the radiation hardness of silicon sensors. This thesis focuses mainly on the investigation of radiation induced defects and their differences observed in various kinds of epitaxial silicon material. Comparisons with other materials like float zone or Czochralski silicon are added. Deep Level Transient Spectroscopy (DLTS) and Thermally Stimulated Current (TSC) measurements have been performed after {gamma}-, electron-, proton- and neutron-irradiation. The differenced in the formation of vacancy and interstitial related defects as well as so-called clustered regions were investigated for various types of irradiation. In addition to the well known defects VO{sub i}, C{sub i}O{sub i}, C{sub i}C{sub s}, VP or V{sub 2} several other defect complexes have been found and investigated. Also the material dependence of the defect introduction rates and the defect annealing behavior has been studied by isothermal and isochronal annealing experiments. Especially the IO{sub 2} defect which is an indicator for the oxygen-dimer content of the material has been investigated in detail. On the basis of radiation induced defects like the bistable donor (BD) defect and a deep

  6. Radiation damage in silicon. Defect analysis and detector properties

    International Nuclear Information System (INIS)

    Hoenniger, F.

    2008-01-01

    Silicon microstrip and pixel detectors are vital sensor-components as particle tracking detectors for present as well as future high-energy physics (HEP) experiments. All experiments at the large Hadron Collider (LHC) are equipped with such detectors. Also for experiments after the upgrade of the LHC (the so-called Super-LHC), with its ten times higher luminosity, or the planned International Linear Collider (ILC) silicon tracking detectors are forseen. Close to the interaction region these detectors have to face harsh radiation fields with intensities above the presently tolerable level. defect engineering of the used material, e. g. oxygen enrichment of high resistivity float zone silicon and growing of thin low resistivityepitaxial layers on Czochralski silicon substrates has been established to improve the radiation hardness of silicon sensors. This thesis focuses mainly on the investigation of radiation induced defects and their differences observed in various kinds of epitaxial silicon material. Comparisons with other materials like float zone or Czochralski silicon are added. Deep Level Transient Spectroscopy (DLTS) and Thermally Stimulated Current (TSC) measurements have been performed after γ-, electron-, proton- and neutron-irradiation. The differenced in the formation of vacancy and interstitial related defects as well as so-called clustered regions were investigated for various types of irradiation. In addition to the well known defects VO i , C i O i , C i C s , VP or V 2 several other defect complexes have been found and investigated. Also the material dependence of the defect introduction rates and the defect annealing behavior has been studied by isothermal and isochronal annealing experiments. Especially the IO 2 defect which is an indicator for the oxygen-dimer content of the material has been investigated in detail. On the basis of radiation induced defects like the bistable donor (BD) defect and a deep acceptor, a model has been introduced to

  7. Department of Radiation Detectors - Overview

    International Nuclear Information System (INIS)

    Piekoszewski, J.

    1997-01-01

    Work carried out in 1996 in the Department of Radiation Detectors concentrated on three subjects: (i) Semiconductor Detectors (ii) X-ray Tube Generators (iii) Material Modification Using Ion and Plasma Beams. The Departamental objectives are: a search for new types of detectors, adapting modern technologies (especially of industrial microelectronics) to detector manufacturing, producing unique detectors tailored for physics experiments, manufacturing standard detectors for radiation measuring instruments. These objectives were accomplished in 1996 by: research on unique detectors for nuclear physics (e.g. a spherical set of particle detectors silicon ball), detectors for particle identification), development of technology of high-resistivity silicon detectors HRSi (grant proposal), development of thermoelectric cooling systems (grant proposal), research on p-i-n photodiode-based personal dosimeters, study of applicability of industrial planar technology in producing detectors, manufacturing detectors developed in previous years, re-generating and servicing customer detectors of various origin. The Department conducts research on the design and technology involved in producing X-ray generators based on X-ray tubes of special construction. Various tube models and their power supplies were developed. Some work has also been devoted to the detection and dosimetry of X-rays. X-ray tube generators are applied to non-destructive testing and are components of analytical systems such as: X-ray fluorescence chemical composition analysis, gauges of layer thickness and composition stress measurements, on-line control of processes, others where an X-ray tube may replace a radio-isotope source. In 1996, the Department: reviewed the domestic demand for X-ray generators, developed an X-ray generator for diagnosis of ostheroporosis of human limbs, prepared a grant proposal for the development of a new instrument for radiotherapy, the so-called needle-like X-ray tube. (author)

  8. Department of Radiation Detectors - Overview

    Energy Technology Data Exchange (ETDEWEB)

    Piekoszewski, J. [Soltan Inst. for Nuclear Studies, Otwock-Swierk (Poland)

    1997-12-31

    Work carried out in 1996 in the Department of Radiation Detectors concentrated on three subjects: (i) Semiconductor Detectors (ii) X-ray Tube Generators (iii) Material Modification Using Ion and Plasma Beams. The Departamental objectives are: a search for new types of detectors, adapting modern technologies (especially of industrial microelectronics) to detector manufacturing, producing unique detectors tailored for physics experiments, manufacturing standard detectors for radiation measuring instruments. These objectives were accomplished in 1996 by: research on unique detectors for nuclear physics (e.g. a spherical set of particle detectors silicon ball), detectors for particle identification), development of technology of high-resistivity silicon detectors HRSi (grant proposal), development of thermoelectric cooling systems (grant proposal), research on p-i-n photodiode-based personal dosimeters, study of applicability of industrial planar technology in producing detectors, manufacturing detectors developed in previous years, re-generating and servicing customer detectors of various origin. The Department conducts research on the design and technology involved in producing X-ray generators based on X-ray tubes of special construction. Various tube models and their power supplies were developed. Some work has also been devoted to the detection and dosimetry of X-rays. X-ray tube generators are applied to non-destructive testing and are components of analytical systems such as: X-ray fluorescence chemical composition analysis, gauges of layer thickness and composition stress measurements, on-line control of processes, others where an X-ray tube may replace a radio-isotope source. In 1996, the Department: reviewed the domestic demand for X-ray generators, developed an X-ray generator for diagnosis of ostheroporosis of human limbs, prepared a grant proposal for the development of a new instrument for radiotherapy, the so-called needle-like X-ray tube. (author).

  9. Analysis of neonicotinoids by gas chromatography coupled to nuclide {sup 63}Ni - Electron Capture Detector - GC/ECD

    Energy Technology Data Exchange (ETDEWEB)

    Amaral, Priscila O.; Leao, Claudio; Redigolo, Marcelo M.; Crepaldi, Caike; Bustillos, Oscar V., E-mail: priscilaoamaral@gmail.com, E-mail: claudio.leao@usp.br, E-mail: marceloredigolo@gmail.com, E-mail: caike1995@gmail.com, E-mail: ovega@ipen.bremails [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2015-07-01

    Recently, several reports have been published discussing reduction in bee population which polymerizes cultures around the world this phenomenon is known as Colony Collapse Disorder (CCD). The phenomenon describes the lack of worker honeybees in the colony despite having pups and food. The causes of this problem are unknown but there are studies that claim that reduction of population of bees is linked to poisoning through insecticides specifically neonicotinoids. Among this type of pesticide are imidacloprid (C{sub 9}H{sub 10}ClN{sub 5}O{sub 2}), clothianidin (C{sub 6}H{sub 8}ClN{sub 5}O{sub 2}S) and thiamethoxam (C{sub 8}H{sub 10}ClN{sub 5}O{sub 3}S). This paper presents the analysis of neonicotinoids - clothianidin, imidacloprid and thiamethoxam - by the technique of gas chromatography coupled to nuclide {sup 63}Ni electron capture detector (GC/ECD). The electron capture detector (ECD) is a gas chromatography detector that has been used for the detection of organic halogens, nitriles, nitrates and organometallic compounds. The ECD detector ionizes the analytes by the beta particles from the nuclide sources {sup 63}Ni within carrier gas N{sub 2}. The electrons produced in this process are collected and create a current that are amplified and generates a chromatographic peak. Methodology and details of the analysis are present in this work. (author)

  10. "Izbori '95" na Hrvatskoj televiziji i u novinama (TV and Newspaper Coverage of the 1995 Elections in Croatia).

    Science.gov (United States)

    Baranovic, Branislava

    1995-01-01

    Presents the results of empirical research of media coverage of recent elections in Croatia. Uses qualitative analysis to examine coverage on broadcasts and in weekly and daily newspapers. Concludes that coverage of political parties was uneven. (PA)

  11. A beam detector for pion experiments and analysis of the inclusive Λ production in proton-proton reactions with HADES

    Energy Technology Data Exchange (ETDEWEB)

    Lalik, Rafal Tomasz

    2016-06-02

    This thesis presents the work focused on two topics related to the physics performed at the HADES detector. In the first part, the development of the tracking detector playing an important role of online beam monitoring and the momentum reconstruction device in the secondary pion beam experiment is presented. Such a detector must fulfill various requirements regarding the operation in the vacuum, with accelerator beams and high count rates. Two detection stations employing double sided silicons strip sensors with an active area of 10 cm x 10 cm and position resolution of 780 μm, providing momentum resolution below 0.5 % and capable for operating with beams up to 32 x 10{sup 6} particles/s total and 2 x 10{sup 6} particles/s in a single channel have been constructed, tested and used in the pion beam experiments. In the first chapter, general information about the production of the secondary, in particular, pion beams is presented. Further, description how the momentum is reconstructed using the information obtained from the tracking detector, and description of most important components of the system, namely the silicon sensor and front end electronics used for its readout is presented. In the second chapter, development of the detector, including all the components used or constructed for this particular purpose is presented. This section also includes description of the laboratory tests and calibrations performed to characterize the detector. In the end of the section, results from two of the beam runs employed for the tests of the detector are presented and discussed. The last third chapter presents results from the commissioning of the tracking detector in the final configuration. Momentum reconstruction feasibility is presented. The second part of the thesis focuses on the analysis of inclusive production of the Λ hyperons in the nuclear reactions at the HADES energies. The aims of the analysis are to extract the differential cross-section of Λ production in

  12. Study on the etching conditions of polycarbonate detectors for particle analysis of safeguards environmental samples

    International Nuclear Information System (INIS)

    Iguchi, K.; Esaka, K.T.; Lee, C.G.; Inagawa, J.; Esaka, F.; Onodera, T.; Fukuyama, H.; Suzuki, D.; Sakurai, S.; Watanabe, K.; Usuda, S.

    2005-01-01

    The fission track technique was applied to the particle analysis for safeguards environmental samples to obtain information about the isotope ratio of nuclear materials in individual particles. To detect the particles containing nuclear material with high detection efficiency and less particle loss, the influence of uranium enrichments on etching conditions of a fission track detector made of polycarbonate was investigated. It was shown that the increase in uranium enrichment shortened the suitable etching time both for particle detection and for less particle loss. From the results obtained, it was suggested that the screening of the uranium particles according to the enrichment is possible by controlling the etching time of the detector

  13. Fast neutron activating detectors for pulsed flow measurements

    International Nuclear Information System (INIS)

    Dyatlov, V.D.; Kunaev, G.T.; Popytaev, A.N.; Cheremukhov, B.V.

    1979-01-01

    The requirements to the activation detectors of the pulsed flows of the fast neutrons are considered; the criteria of optimum measurement time, geometrical moderator sizes and radioactive detector element properties have been obtained. On their analysis parameter selection has been carried out. The neutron detector to register the short pulses has been designed and calibrated. The ways of further increase of sensitivity and efficiency of such detectors are discussed

  14. Analysis of print media coverage of nuclear power issues

    International Nuclear Information System (INIS)

    Rankin, W.L.; Nealey, S.M.; Montano, D.E.

    1978-04-01

    224 newspaper articles were sampled from four newspapers, extrapolating to about 2850 nuclear power articles from 1972 to 1976. 124 magazine articles were found in four magazines (Time, Business Week, Scientific American, Environment). The newspapers wee found to run close coverage of nuclear power issues. The articles were mainly (45%) focused on reactors and reactor operation. The articles were judged to be antinuclear more often than pronuclear (only Scientific American discussed benefits more than costs). The same general conclusion was reached for articles on nuclear waste management

  15. Evaluation of fault coverage for digitalized system in nuclear power plants using VHDL

    International Nuclear Information System (INIS)

    Kim, Suk Joon; Lee, Jun Suk; Seong, Poong Hyun

    2003-01-01

    Fault coverage of digital systems is found to be one of the most important factors in the safety analysis of nuclear power plants. Several axiomatic models for the estimation of fault coverage of digital systems have been proposed, but to apply those axiomatic models to real digital systems, parameters that the axiomatic models require should be approximated using analytic methods, empirical methods or expert opinions. In this paper, we apply the fault injection method to VHDL computer simulation model of a real digital system which provides the protection function to nuclear power plants, for the approximation of fault detection coverage of the digital system. As a result, the fault detection coverage of the digital system could be obtained

  16. Ionization detector

    International Nuclear Information System (INIS)

    Steele, D.S.

    1987-01-01

    An ionization detector having an array of detectors has, for example, grounding pads positioned in the spaces between some detectors (data detectors) and other detectors (reference detectors). The grounding pads are kept at zero electric potential, i.e. grounded. The grounding serves to drain away electrons and thereby prevent an unwanted accumulation of charge in the spaces, and cause the electric field lines to be more perpendicular to the detectors in regions near the grounding pads. Alternatively, no empty space is provided there being additional, grounded, detectors provided between the data and reference detectors. (author)

  17. Search of new resonances decaying into top quark pairs with the ATLAS detector at the LHC and jet calibration studies

    International Nuclear Information System (INIS)

    Camacho, R.

    2012-01-01

    The studies presented in this thesis were performed using data collected by the ATLAS detector at the LHC. The ATLAS detector consists of a tracking system in a 2 T solenoid field, providing coverage up to a pseudo-rapidity of |η| -1 of data collected by the ATLAS detector in 2011. Secondly and related to this search, performance studies of the Jet Vertex Fraction (JVF) in top-quark pairs topologies are presented too. JVF is a variable that can be used to reduce the pile-up effects to improve the precision and sensitivity of physics analyses at high luminosities. Finally, results regarding the performance, validation in data and associated systematic uncertainty derivation of the Global Sequential (GS) jet calibration are discussed

  18. Selective data analysis for diamond detectors in neutron fields

    Directory of Open Access Journals (Sweden)

    Weiss Christina

    2017-01-01

    Full Text Available Detectors based on synthetic chemical vapor deposition diamond gain importance in various neutron applications. The superior thermal robustness and the excellent radiation hardness of diamond as well as its excellent electronic properties make this material uniquely suited for rough environments, such as nuclear fission and fusion reactors. The intrinsic electronic properties of single-crystal diamond sensors allow distinguishing various interactions in the detector. This can be used to successfully suppress background of γ-rays and charged particles in different neutron experiments, such as neutron flux measurements in thermal nuclear reactors or cross-section measurements in fast neutron fields. A novel technique of distinguishing background reactions in neutron experiments with diamond detectors will be presented. A proof of principle will be given on the basis of experimental results in thermal and fast neutron fields.

  19. 29 CFR 2.13 - Audiovisual coverage prohibited.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 1 2010-07-01 2010-07-01 true Audiovisual coverage prohibited. 2.13 Section 2.13 Labor Office of the Secretary of Labor GENERAL REGULATIONS Audiovisual Coverage of Administrative Hearings § 2.13 Audiovisual coverage prohibited. The Department shall not permit audiovisual coverage of the...

  20. Multi-detector computed tomography of acute abdomen

    International Nuclear Information System (INIS)

    Leschka, Sebastian; Alkadhi, Hatem; Wildermuth, Simon; Marincek, Borut; University Hospital of Zurich

    2005-01-01

    Acute abdominal pain is one of the most common causes for referrals to the emergency department. The sudden onset of severe abdominal pain characterising the ''acute abdomen'' requires rapid and accurate identification of a potentially life-threatening abdominal pathology to provide a timely referral to the appropriate physician. While the physical examination and laboratory investigations are often non-specific, computed tomography (CT) has evolved as the first-line imaging modality in patients with an acute abdomen. Because the new multi-detector CT (MDCT) scanner generations provide increased speed, greater volume coverage and thinner slices, the acceptance of CT for abdominal imaging has increased rapidly. The goal of this article is to discuss the role of MDCT in the diagnostic work-up of acute abdominal pain. (orig.)

  1. The analysis of the gamma-ray pulseheight spectra resulting from the NaI detector

    International Nuclear Information System (INIS)

    Huang Zhengde; Zhang Guishan; Chen Qun; Cao Zhong

    1990-01-01

    The analysis of the Gamma-ray pulse-height spectra resulting from NaI detector is described by using weighted least square iteration. The computer program has the function of searching for Gamma-ray peak automatically. It can be used in the analysis of continuous, discrete or their superposition spectra. Besides, there are some function of the spectrum smooth,the correction of the shift in gain and zero energy channel intercept. Some results of the computer program are presented

  2. Impact of statin related media coverage on use of statins: interrupted time series analysis with UK primary care data.

    Science.gov (United States)

    Matthews, Anthony; Herrett, Emily; Gasparrini, Antonio; Van Staa, Tjeerd; Goldacre, Ben; Smeeth, Liam; Bhaskaran, Krishnan

    2016-06-28

     To quantify how a period of intense media coverage of controversy over the risk:benefit balance of statins affected their use.  Interrupted time series analysis of prospectively collected electronic data from primary care.  Clinical Practice Research Datalink (CPRD) in the United Kingdom.  Patients newly eligible for or currently taking statins for primary and secondary cardiovascular disease prevention in each month in January 2011-March 2015.  Adjusted odds ratios for starting/stopping taking statins after the media coverage (October 2013-March 2014).  There was no evidence that the period of high media coverage was associated with changes in statin initiation among patients with a high recorded risk score for cardiovascular disease (primary prevention) or a recent cardiovascular event (secondary prevention) (odds ratio 0.99 (95% confidence interval 0.87 to 1.13; P=0.92) and 1.04 (0.92 to 1.18; P=0.54), respectively), though there was a decrease in the overall proportion of patients with a recorded risk score. Patients already taking statins were more likely to stop taking them for both primary and secondary prevention after the high media coverage period (1.11 (1.05 to 1.18; P<0.001) and 1.12 (1.04 to 1.21; P=0.003), respectively). Stratified analyses showed that older patients and those with a longer continuous prescription were more likely to stop taking statins after the media coverage. In post hoc analyses, the increased rates of cessation were no longer observed after six months.  A period of intense public discussion over the risks:benefit balance of statins, covered widely in the media, was followed by a transient rise in the proportion of people who stopped taking statins. This research highlights the potential for widely covered health stories in the lay media to impact on healthcare related behaviour. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  3. Newspaper coverage of youth and tobacco: implications for public health.

    Science.gov (United States)

    Smith, Katherine Clegg; Wakefield, Melanie

    2006-01-01

    The presentation of smoking as a "youth" issue is a powerful component of current tobacco-control efforts. Agenda setting theory demonstrates that the media serve as a potent forum in which the consideration and presentation of perspectives of social problems take place. This analysis of 643 U.S. youth-focused newspaper articles examines the messages being conveyed to the public and policymakers through coverage of tobacco issues focused on youth. Data illustrate that the issue of youth tobacco use is newsworthy but also suggest that youth-focused issues garner little commentary coverage. Rather, straightforward reports of "feel good" stories dominate the coverage, and youth-focused articles tend to conceptualize the problem of tobacco as being one of a need for greater individual-level education rather than structural or policy changes.

  4. Counting radon tracks in Makrofol detectors with the 'image reduction and analysis facility' (IRAF) software package

    International Nuclear Information System (INIS)

    Hernandez, F.; Gonzalez-Manrique, S.; Karlsson, L.; Hernandez-Armas, J.; Aparicio, A.

    2007-01-01

    Makrofol detectors are commonly used for long-term radon ( 222 Rn) measurements in houses, schools and workplaces. The use of this type of passive detectors for the determination of radon concentrations requires the counting of the nuclear tracks produced by alpha particles on the detecting material. The 'image reduction and analysis facility' (IRAF) software package is a piece of software commonly used in astronomical applications. It allows detailed counting and mapping of sky sections where stars are grouped very closely, even forming clusters. In order to count the nuclear tracks in our Makrofol radon detectors, we have developed an inter-disciplinary application that takes advantage of the similitude that exist between counting stars in a dark sky and tracks in a track-etch detector. Thus, a low cost semi-automatic system has been set up in our laboratory which utilises a commercially available desktop scanner and the IRAF software package. A detailed description of the proposed semi-automatic method and its performance, in comparison to ocular counting, is described in detail here. In addition, the calibration factor for this procedure, 2.97+/-0.07kBqm -3 htrack -1 cm 2 , has been calculated based on the results obtained from exposing 46 detectors to certified radon concentrations. Furthermore, the results of a preliminary radon survey carried out in 62 schools in Tenerife island (Spain), using Makrofol detectors, counted with the mentioned procedure, are briefly presented. The results reported here indicate that the developed procedure permits a fast, accurate and unbiased determination of the radon tracks in a large number of detectors. The measurements carried out in the schools showed that the radon concentrations in at least 12 schools were above 200Bqm -3 and, in two of them, above 400Bqm -3 . Further studies should be performed at those schools following the European Union recommendations about radon concentrations in buildings

  5. High performance visual display for HENP detectors

    CERN Document Server

    McGuigan, M; Spiletic, J; Fine, V; Nevski, P

    2001-01-01

    A high end visual display for High Energy Nuclear Physics (HENP) detectors is necessary because of the sheer size and complexity of the detector. For BNL this display will be of special interest because of STAR and ATLAS. To load, rotate, query, and debug simulation code with a modern detector simply takes too long even on a powerful work station. To visualize the HENP detectors with maximal performance we have developed software with the following characteristics. We develop a visual display of HENP detectors on BNL multiprocessor visualization server at multiple level of detail. We work with general and generic detector framework consistent with ROOT, GAUDI etc, to avoid conflicting with the many graphic development groups associated with specific detectors like STAR and ATLAS. We develop advanced OpenGL features such as transparency and polarized stereoscopy. We enable collaborative viewing of detector and events by directly running the analysis in BNL stereoscopic theatre. We construct enhanced interactiv...

  6. Neutrino induced events in the MINOS detectors

    Energy Technology Data Exchange (ETDEWEB)

    Litchfield, Reuben Phillip [Univ. of Oxford (United Kingdom). Keble College

    2008-01-01

    The MINOS experiment is designed to study neutrino oscillations. It uses an accelerator generated beam of neutrinos and two detectors, the smaller at a distance of 1km and the larger at 735 km. By comparing the spectrum and flavour composition of the beam at the two detectors precise determinations of the oscillation parameters are possible. This thesis concentrates on the analysis of data from the larger Far Detector. By studying the spectrum of neutral current events it is possible to look for evidence of non-interacting 'sterile' neutrinos. The thesis describes how events are selected for this analysis, and a method for discriminating between charged current and neutral current events. The systematic uncertainties resulting from these cuts are evaluated. Several techniques for using Near Detector data to eliminate systematic uncertainties in the predicted Far Detector spectrum are compared. An oscillation analysis, based on the first year of MINOS data, uses the selected events to make a measurement of f{sub s}, the fraction of unseen neutrinos that are sterile. The measured value is fs = 0.07+0.32 at 68%C.L., and is consistent with the standard three-neutrino picture, which has no sterile neutrino.

  7. SWATHtoMRM: Development of High-Coverage Targeted Metabolomics Method Using SWATH Technology for Biomarker Discovery.

    Science.gov (United States)

    Zha, Haihong; Cai, Yuping; Yin, Yandong; Wang, Zhuozhong; Li, Kang; Zhu, Zheng-Jiang

    2018-03-20

    The complexity of metabolome presents a great analytical challenge for quantitative metabolite profiling, and restricts the application of metabolomics in biomarker discovery. Targeted metabolomics using multiple-reaction monitoring (MRM) technique has excellent capability for quantitative analysis, but suffers from the limited metabolite coverage. To address this challenge, we developed a new strategy, namely, SWATHtoMRM, which utilizes the broad coverage of SWATH-MS technology to develop high-coverage targeted metabolomics method. Specifically, SWATH-MS technique was first utilized to untargeted profile one pooled biological sample and to acquire the MS 2 spectra for all metabolites. Then, SWATHtoMRM was used to extract the large-scale MRM transitions for targeted analysis with coverage as high as 1000-2000 metabolites. Then, we demonstrated the advantages of SWATHtoMRM method in quantitative analysis such as coverage, reproducibility, sensitivity, and dynamic range. Finally, we applied our SWATHtoMRM approach to discover potential metabolite biomarkers for colorectal cancer (CRC) diagnosis. A high-coverage targeted metabolomics method with 1303 metabolites in one injection was developed to profile colorectal cancer tissues from CRC patients. A total of 20 potential metabolite biomarkers were discovered and validated for CRC diagnosis. In plasma samples from CRC patients, 17 out of 20 potential biomarkers were further validated to be associated with tumor resection, which may have a great potential in assessing the prognosis of CRC patients after tumor resection. Together, the SWATHtoMRM strategy provides a new way to develop high-coverage targeted metabolomics method, and facilitates the application of targeted metabolomics in disease biomarker discovery. The SWATHtoMRM program is freely available on the Internet ( http://www.zhulab.cn/software.php ).

  8. Partisan differences in the relationship between newspaper coverage and concern over global warming.

    Science.gov (United States)

    Zhao, Xiaoquan; Rolfe-Redding, Justin; Kotcher, John E

    2016-07-01

    The effects of news media on public opinion about global warming have been a topic of much interest in both academic and popular discourse. Empirical evidence in this regard, however, is still limited and somewhat mixed. This study used data from the 2006 General Social Survey in combination with a content analysis of newspaper coverage of the same time period to examine the relationship between general news climate and public concern about global warming. Results showed a pattern of political polarization, with increased coverage associated with growing divergence between Democrats and Republicans. Further analysis also showed evidence of reactivity in partisan response to coverage from different news outlets. These findings point to a particular form of politically motivated, biased processing of news information. © The Author(s) 2014.

  9. SiliPET: Design of an ultra-high resolution small animal PET scanner based on stacks of semi-conductor detectors

    International Nuclear Information System (INIS)

    Cesca, N.; Auricchio, N.; Di Domenico, G.; Zavattini, G.; Malaguti, R.; Andritschke, R.; Kanbach, G.; Schopper, F.

    2007-01-01

    We studied with Monte Carlo simulations, using the EGSnrc code, a new scanner for small animal positron emission tomography (PET), based on stacks of double-sided semiconductor detectors. Each stack is composed of planar detectors with dimension 70x60x1 mm 3 and orthogonal strips on both sides with 500 μm pitch to read the two interaction coordinates, the third being the detector number in the stack. Multiple interactions in a stack are discarded. In this way, we achieve a precise determination of the first interaction point of the two 511 keV photons. The reduced dimensions of the scanner also improve the solid angle coverage resulting in a high sensitivity. Preliminary results of scanners based on Si planar detectors are presented and the initial tomographic reconstructions demonstrate very good spatial resolution limited only by the positron range. This suggests that, this is a promising new approach for small animal PET imaging. We are testing some double-sided silicon detectors, equipped with 128 orthogonal p and n strips on opposite sides using VATAGP3 ASIC by IDEAS

  10. Energy and angular responses of the criticality accident detector using a plastic scintillator

    International Nuclear Information System (INIS)

    Tsujimura, Norio; Yoshida, Tadayoshi

    2006-01-01

    The Japan Atomic Energy Agency (JAEA), Nuclear Fuel Cycle Engineering Laboratories, operates a spent fuel reprocessing plant and MOX (Plutonium-Uranium Mixed Oxide) fuel fabrication plants. Criticality accident detectors have been installed in these facilities. The detector, the Toshiba RD120, is composed of a plastic scintillator coupled to a photomultiplier tube, and an operational amplifier. The alarm triggering point is set to 1.0-3.6 mGy·h -1 in photon dose rate to detect the minimum accident of concern. However, a plastic scintillator is principally sensitive not only to primary photons but also to neutrons by secondary photons and heavy charged particles produced in the detector itself. The authors calculated energy and angular responses of the RD120 criticality accident detector to photons and neutrons using Monte Carlo computer codes. The response to primary photons was evaluated with the MCNP-4B and EGS4 calculations, and photon and X-ray irradiation experiments. The response to neutrons that produce secondary photons and heavy charged particles from neutron interactions was computed using the MCNP-4B and SCINFUL, respectively. As a result, reliable response functions were obtained. These results will be a great help in reassessing the coverage area and in determining the appropriate triggering dose rate level in criticality accidents. (author)

  11. Agricultural News Coverage In The Print Media In Nigeria: A ...

    African Journals Online (AJOL)

    The focus of this paper is on the comparative analysis of agricultural news coverage in three categories of newspapers in Nigeria. The three newspapers under study were New Nigerian, Pointer and Vanguard newspapers. Data were analysed using frequency counts, and percentages and Analysis of Variance. The pointer ...

  12. Newspaper coverage of maternal health in Bangladesh, Rwanda and South Africa: a quantitative and qualitative content analysis

    Science.gov (United States)

    Gugsa, Frey; Karmarkar, Ellora; Cheyne, Andrew; Yamey, Gavin

    2016-01-01

    Objective To examine newspaper coverage of maternal health in three countries that have made varying progress towards Millennium Development Goal 5 (MDG 5): Bangladesh (on track), Rwanda (making progress, but not on track) and South Africa (no progress). Design We analysed each country's leading national English-language newspaper: Bangladesh's The Daily Star, Rwanda's The New Times/The Sunday Times, and South Africa's Sunday Times/The Times. We quantified the number of maternal health articles published from 1 January 2008 to 31 March 2013. We conducted a content analysis of subset of 190 articles published from 1 October 2010 to 31 March 2013. Results Bangladesh's The Daily Star published 579 articles related to maternal health from 1 January 2008 to 31 March 2013, compared to 342 in Rwanda's The New Times/The Sunday Times and 253 in South Africa's Sunday Times/The Times over the same time period. The Daily Star had the highest proportion of stories advocating for or raising awareness of maternal health. Most maternal health articles in The Daily Star (83%) and The New Times/The Sunday Times (69%) used a ‘human-rights’ or ‘policy-based’ frame compared to 41% of articles from Sunday Times/The Times. Conclusions In the three countries included in this study, which are on different trajectories towards MDG 5, there were differences in the frequency, tone and content of their newspaper coverage of maternal health. However, no causal conclusions can be drawn about this association between progress on MDG 5 and the amount and type of media coverage of maternal health. PMID:26769780

  13. Event timing in high purity germanium coaxial detectors

    International Nuclear Information System (INIS)

    El-Ibiary, M.Y.

    1979-08-01

    The timing of gamma ray radiation in systems using high purity coaxial germanium detectors is analyzed and compared to that of systems using Ge(Li) detectors. The analysis takes into account the effect of the residual impurities on the electric field distribution, and hence on the rate of rise of the electrical pulses delivered to the timing module. Conditions under which the electric field distribution could lead to an improvement in timing performance, are identified. The results of the analysis confirm the experimental results published elsewhere and when compared with those for Ge(Li) detectors, which usually operate under conditions of charge carrier velocity saturation, confirm that high purity germanium detectors need not have inferior timing characteristics. A chart is given to provide a quantitative basis on which the trade off between the radius of the detector and its time resolution may be made

  14. Performance of an AGATA asymmetric detector

    Energy Technology Data Exchange (ETDEWEB)

    Boston, A.J. [Department of Physics, University of Liverpool, Liverpool L69 7ZE (United Kingdom)], E-mail: ajboston@liv.ac.uk; Dimmock, M.R.; Unsworth, C.; Boston, H.C.; Cooper, R.J.; Grint, A.N.; Harkness, L.J. [Department of Physics, University of Liverpool, Liverpool L69 7ZE (United Kingdom); Lazarus, I.H. [STFC Daresbury Laboratory, Daresbury, Warrington WA4 4AD (United Kingdom); Jones, M.; Nolan, P.J.; Oxley, D.C. [Department of Physics, University of Liverpool, Liverpool L69 7ZE (United Kingdom); Simpson, J. [STFC Daresbury Laboratory, Daresbury, Warrington WA4 4AD (United Kingdom); Slee, M. [Department of Physics, University of Liverpool, Liverpool L69 7ZE (United Kingdom)

    2009-06-01

    High-resolution gamma-ray detectors based on high-purity germanium crystals (HPGe) are one of the key workhorses of experimental nuclear science. The technical development of such detector technology has been dramatic in recent years. Large volume, high-granularity, electrically segmented HPGe detectors have been realised and a methodology to improve position sensitivity using pulse-shape analysis coupled with the novel technique of gamma-ray tracking has been developed. Collaborations have been established in Europe (Advanced GAmma Tracking Array (AGATA)) [J. Simpson, Acta Phys. Pol. B 36 (2005) 1383] and the USA (GRETA/GRETINA) [C.W. Beausang, Nucl. Instr. and Meth. B 204 (2003)] to build gamma-ray tracking spectrometers. This paper discusses the performance of the first AGATA asymmetric detector that has been tested at the University of Liverpool. The use of a fully digital data acquisition system has allowed detector charge pulse shapes from a selection of well-defined photon interaction positions to be analysed, yielding important information on the position sensitivity of the detector.

  15. 42 CFR 440.330 - Benchmark health benefits coverage.

    Science.gov (United States)

    2010-10-01

    ...) Federal Employees Health Benefit Plan Equivalent Coverage (FEHBP—Equivalent Health Insurance Coverage). A... coverage. Health benefits coverage that is offered and generally available to State employees in the State... 42 Public Health 4 2010-10-01 2010-10-01 false Benchmark health benefits coverage. 440.330 Section...

  16. Program for the analysis of pulse height spectra and the background from a proportional detector

    International Nuclear Information System (INIS)

    Flores-Llamas, H.; Yee-Madeira, H.; Contreras-Puente, G.; Zamorano-Ulloa, R.

    1991-01-01

    A PC-Fortran program is presented for fitting of lineshapes and the analysis of pulse height spectra obtainable with proportional detectors. The common fitting and analysis of pulse height spectra by means of mixed Gaussian lineshapes is readily improved by using Voigt lineshapes. In addition, the background can be evaluated during the fitting process without the need of extra measurements. As an application of the program, a pulse height transmission spectrum accumulated with a static 57 Co source and detected with an argon-metane proportional detector, was least squares fitted to an elaborated complex trial lineshape function containing two Voigt lines plus a straight line. The fitting straight line parameters a and b characterize quantitatively the background. The very good PC-fitting obtained shows that the fitting of experimental spectra with the more realistic Voigt lineshapes is no longer a formidable task and that it is possible to evaluate and subtract the background inherent to the experiment during the fitting process. (orig.)

  17. The relevance of the social context for media coverage of victims

    Directory of Open Access Journals (Sweden)

    Pavićević Olivera

    2017-01-01

    Full Text Available Media coverage of human suffering caused by trauma, illness, poverty and disasters worldwide takes up a significant part of media coverage and affects the identity of all actors, both active and passive. Media presentation shapes our thinking and reasoning at the group level, and has far reached impact. The social context of media reporting on victims is shaped by the capacity of the social system to recognize, acknowledge, strengthen and protect the victim. As an aspect of this capacity, media coverage of victims is indicator of victimization visibility. This paper discusses nature of media reporting as a phenomenon appearing in various forms as per given sources of victimization, and the ethical aspects of media presentation of victims. The aim of the paper is to contribute to the critical analysis of the media coverage of victims, by reconsidering an increased visibility of victims and their suffering, which is generated by media reporting, and whose dominant characteristic is presenting victims in the interpretative and performing manner.

  18. Thermoelectrically cooled semiconductor detectors for non-destructive analysis of works of art by means of energy dispersive X-ray fluorescence

    International Nuclear Information System (INIS)

    Cesareo, Roberto; Ettore Gigante, Giovanni; Castellano, Alfredo

    1999-01-01

    Thermoelectrically cooled semiconductor detectors, such as Si-PIN, Si-drift, Cd 1-x Zn x Te and HgI 2 , coupled to miniaturized low-power X-ray tubes, are well suited in portable systems for energy-dispersive X-ray fluorescence (EDXRF), analysis of archaeological samples. The Si-PIN detector is characterized by a thickness of about 300 μm, an area of about 2x3 mm 2 , an energy resolution of about 200-250 eV at 5.9 keV and an entrance window of 25-75 μm. The Si-drift detector has approximately the same area and thickness, but an energy resolution of 155 eV at 5.9 keV. The efficiency of these detectors is around 100% from 4 to 10 keV, and then decreases versus energy, reaching ∼9% at 30 keV. Coupled to a miniaturized 10 kV, 0.1 mA, Ca-anode or to a miniaturized 30 kV, 0.1 mA, W-anode X-ray tubes, portable systems can be constructed, which are able to analyse K-lines of elements up to about silver, and L-lines of heavy elements. The Cd 1-x Zn x Te detector has an area of 4 mm 2 and a thickness of 3 mm. It has an energy resolution of about 300 eV at 5.9 keV, and an efficiency of 100% over the whole range of X-rays. Finally the HgI 2 detector has an efficiency of about 100% in the whole range of X-rays, and an energy resolution of about 200 eV at 5.9 keV. Coupled to a small 50-60 kV, 1 mA, W-anode X-ray tube, portable systems can be constructed, for the analysis of practically all elements. These systems were applied to analysis in the field of archaeometry and in all applications for which portable systems are needed or at least useful (for example X-ray transmission measurements, X-ray microtomography and so on). Results of in-field use of these detectors and a comparison among these room temperature detectors in relation to concrete applications are presented. More specifically, concerning EDXRF analysis, ancient gold samples were analysed in Rome, in Mexico City and in Milan, ancient bronzes in Sassari, in Bologna, in Chieti and in Naples, and sulfur (due to

  19. Applying Statistical Mechanics to pixel detectors

    International Nuclear Information System (INIS)

    Pindo, Massimiliano

    2002-01-01

    Pixel detectors, being made of a large number of active cells of the same kind, can be considered as significant sets to which Statistical Mechanics variables and methods can be applied. By properly redefining well known statistical parameters in order to let them match the ones that actually characterize pixel detectors, an analysis of the way they work can be performed in a totally new perspective. A deeper understanding of pixel detectors is attained, helping in the evaluation and comparison of their intrinsic characteristics and performance

  20. Nanopatterned surface with adjustable area coverage and feature size fabricated by photocatalysis

    Energy Technology Data Exchange (ETDEWEB)

    Bai Yang; Zhang Yan; Li Wei; Zhou Xuefeng; Wang Changsong; Feng Xin [State Key Laboratory of Materials-oriented Chemical Engineering, Nanjing University of Technology, Nanjing, Jiangsu 210009 (China); Zhang Luzheng [Petroleum Research Recovery Center, New Mexico Institute of Mining and Technology, Socorro, NM 87801 (United States); Lu Xiaohua, E-mail: xhlu@njut.edu.cn [State Key Laboratory of Materials-oriented Chemical Engineering, Nanjing University of Technology, Nanjing, Jiangsu 210009 (China)

    2009-08-30

    We report an effective approach to fabricate nanopatterns of alkylsilane self-assembly monolayers (SAMs) with desirable coverage and feature size by gradient photocatalysis in TiO{sub 2} aqueous suspension. Growth and photocatalytic degradation of octadecyltrichlorosilane (OTS) were combined to fabricate adjustable monolayered nanopatterns on mica sheet in this work. Systematic atomic force microscopy (AFM) analysis showed that OTS-SAMs that have similar area coverage with different feature sizes and similar feature size with different area coverages can be fabricated by this approach. Contact angle measurement was applied to confirm the gradually varied nanopatterns contributed to the gradient of UV light illumination. Since this approach is feasible for various organic SAMs and substrates, a versatile method was presented to prepare tunable nanopatterns with desirable area coverage and feature size in many applications, such as molecular and biomolecular recognition, sensor and electrode modification.

  1. Nanopatterned surface with adjustable area coverage and feature size fabricated by photocatalysis

    International Nuclear Information System (INIS)

    Bai Yang; Zhang Yan; Li Wei; Zhou Xuefeng; Wang Changsong; Feng Xin; Zhang Luzheng; Lu Xiaohua

    2009-01-01

    We report an effective approach to fabricate nanopatterns of alkylsilane self-assembly monolayers (SAMs) with desirable coverage and feature size by gradient photocatalysis in TiO 2 aqueous suspension. Growth and photocatalytic degradation of octadecyltrichlorosilane (OTS) were combined to fabricate adjustable monolayered nanopatterns on mica sheet in this work. Systematic atomic force microscopy (AFM) analysis showed that OTS-SAMs that have similar area coverage with different feature sizes and similar feature size with different area coverages can be fabricated by this approach. Contact angle measurement was applied to confirm the gradually varied nanopatterns contributed to the gradient of UV light illumination. Since this approach is feasible for various organic SAMs and substrates, a versatile method was presented to prepare tunable nanopatterns with desirable area coverage and feature size in many applications, such as molecular and biomolecular recognition, sensor and electrode modification.

  2. Quantitative Characterization of Phosphor Detector for Fusion Plasmas

    International Nuclear Information System (INIS)

    Baciero, A.; Zurro, B.; McCarthy, K. J.

    2004-01-01

    Experiments made to characterize phosphor screens with application as broadband radiation detectors, are described. Several radiation sources, covering the spectral range between the ultraviolet and X ray, were used. In addition, details are given of three original phosphor-screen-based detectors that were designed for use as broadband detectors in magnetically confined fusion devices. The first measurements obtained with these detectors in plasmas created in the TJ-II stellarator device are presented together with the analysis performed. (Author)

  3. BEGe detectors in GERDA Phase I - performance, physics analysis and surface events

    Energy Technology Data Exchange (ETDEWEB)

    Lazzaro, Andrea [Physik-Department E15, Technische Universitaet Muenchen (Germany); Collaboration: GERDA-Collaboration

    2014-07-01

    The Phase I of the Gerda experiment, which has concluded its data taking in Summer 2013, was based on coaxial HPGe detectors already used for IGEX and HdM experiments. In the upcoming Phase II customized Broad Energy Germanium (BEGe) detectors will provide the major contribution to the total exposure. The first set of BEGe detectors has been deployed in Gerda since June 2012. The data collected in Phase I show the performance achieved in terms of spectroscopy and pulse shape discrimination. In particular the strongest background source, the {sup 42}K beta decay from the liquid argon surrounding the detectors, has been effectively rejected. The signals due to beta decay on the detector surface are indeed characterized by a longer charge collection time. This talk focuses on this key feature of the BEGe-PSD.

  4. An Analysis of Television's Coverage of the "Iran Crisis": 5 November 1979 to 15 January 1980.

    Science.gov (United States)

    Miller, Christine

    The three television networks, acting under severe restrictions imposed by the Iranian government, all provided comprehensive coverage of the hostage crisis. A study was conducted to examine what, if any, salient differences arose or existed in this coverage from November 5, 1979, until January 15, 1980. A research procedure combining qualitative…

  5. 40 CFR 51.356 - Vehicle coverage.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 2 2010-07-01 2010-07-01 false Vehicle coverage. 51.356 Section 51.356....356 Vehicle coverage. The performance standard for enhanced I/M programs assumes coverage of all 1968 and later model year light duty vehicles and light duty trucks up to 8,500 pounds GVWR, and includes...

  6. GEO 600 online detector characterization system

    International Nuclear Information System (INIS)

    Balasubramanian, R; Babak, S; Churches, D; Cokelaer, T

    2005-01-01

    A world-wide network of interferometric gravitational wave detectors is currently operational. The detectors in the network are still in their commissioning phase and are expected to achieve their design sensitivity over the next year or so. Each detector is a complex instrument involving many optical, mechanical and electronic subsystems and each subsystem is a source of noise at the output of the detector. Therefore, in addition to recording the main gravitational wave data channel at the output of the interferometer, the state of each detector subsystem is monitored and recorded. The analysis of these subsidiary data serves a dual purpose: first, it helps us to identify the primary sources of noise which could then be either removed altogether or reduced substantially and second, it helps us in vetoing spurious signals at the output of the interferometer. However, since these subsidiary data are both large in volume (1 MB s -1 ) as well as complex in nature, it is not possible to look at all these data manually. We require an online monitoring and analysis tool which can process all the data channels for various noise artefacts such as transients, drifting of narrowband noise sources, noise couplings between data channels etc, and summarize the results of the analysis in a manner that can be accessed and interpreted conveniently. In this paper we describe the GEO 600 online detector characterization system (GODCS), which is the tool that is being used to monitor the output of the GEO 600 gravitational wave detector situated near Hanover in Germany. We describe the various algorithms that we use and how the results of several algorithms can be combined to make meaningful statements about the state of the detector. We also give implementation details such as the software architecture and the storage and retrieval of the output of GODCS. This paper will be useful to researchers in the area of gravitational wave astronomy as a record of the various analyses and

  7. Muon detector for the COSINE-100 experiment

    Science.gov (United States)

    Prihtiadi, H.; Adhikari, G.; Adhikari, P.; Barbosa de Souza, E.; Carlin, N.; Choi, S.; Choi, W. Q.; Djamal, M.; Ezeribe, A. C.; Ha, C.; Hahn, I. S.; Hubbard, A. J. F.; Jeon, E. J.; Jo, J. H.; Joo, H. W.; Kang, W.; Kang, W. G.; Kauer, M.; Kim, B. H.; Kim, H.; Kim, H. J.; Kim, K. W.; Kim, N. Y.; Kim, S. K.; Kim, Y. D.; Kim, Y. H.; Kudryavtsev, V. A.; Lee, H. S.; Lee, J.; Lee, J. Y.; Lee, M. H.; Leonard, D. S.; Lim, K. E.; Lynch, W. A.; Maruyama, R. H.; Mouton, F.; Olsen, S. L.; Park, H. K.; Park, H. S.; Park, J. S.; Park, K. S.; Pettus, W.; Pierpoint, Z. P.; Ra, S.; Rogers, F. R.; Rott, C.; Scarff, A.; Spooner, N. J. C.; Thompson, W. G.; Yang, L.; Yong, S. H.

    2018-02-01

    The COSINE-100 dark matter search experiment has started taking physics data with the goal of performing an independent measurement of the annual modulation signal observed by DAMA/LIBRA. A muon detector was constructed by using plastic scintillator panels in the outermost layer of the shield surrounding the COSINE-100 detector. It detects cosmic ray muons in order to understand the impact of the muon annual modulation on dark matter analysis. Assembly and initial performance tests of each module have been performed at a ground laboratory. The installation of the detector in the Yangyang Underground Laboratory (Y2L) was completed in the summer of 2016. Using three months of data, the muon underground flux was measured to be 328 ± 1(stat.)± 10(syst.) muons/m2/day. In this report, the assembly of the muon detector and the results from the analysis are presented.

  8. Coordinate-sensitive charged particle detector for spectroscopy

    Directory of Open Access Journals (Sweden)

    Sidorenko V. P.

    2016-10-01

    Full Text Available The authors have designed, manufactured and tested a coordinate-sensitive detector for charged particle spectroscopy. The detector can be used in the devices for the elemental analysis of materials, providing simultaneous analysis of all the elemental composition with high sensitivity and precision. The designed device is based on an integrated circuit (IC and a microchannel plate (MCP electron multiplier. The IC is mounted on a ceramic substrate. Ions fall on the MCP mounted above the IC. Giving rise to a pulse which typically exceeds 106 electrons, each ion falls on the detector electrodes and these pulses are counted. In this research, a two stage stack of MCPs (Hamamatsu was used. The MCPs have a channel diameter of 12 μm on a 15 μm pitch. The results of tests carried out in a mass spectrometer are presented. The designed detector is small, light, and low-power.

  9. Advanced detector systems; What do they have to offer for activation analysis

    Energy Technology Data Exchange (ETDEWEB)

    Bode, P [Technische Univ. Delft (Netherlands); Lindstrom, R M [National Inst. of Standards and Technology, Gaithersburg, MD (United States)

    1993-01-01

    Neutron activated reference materials have been analyzed using a standard Ge(Li)-detector with 17% relative efficiency, a very large Ge-detector with 96% relative efficiency, and a well-type Ge detector. Sensitivities are presented, and usefulness of these systems for NAA is compared on the basis of performance, economics and complexity. (author) 10 refs.; 3 figs.; 4 tabs.

  10. Detectors for proton counting. Si-APD and scintillation detectors

    International Nuclear Information System (INIS)

    Kishimoto, Shunji

    2008-01-01

    Increased intensity of synchrotron radiation requests users to prepare photon pulse detectors having higher counting rates. As detectors for photon counting, silicon-avalanche photodiode (Si-APD) and scintillation detectors were chosen for the fifth series of detectors. Principle of photon detection by pulse and need of amplification function of the detector were described. Structure and working principle, high counting rate measurement system, bunch of electrons vs. counting rate, application example of NMR time spectroscopy measurement and comments for users were described for the Si-APD detector. Structure of scintillator and photomultiplier tube, characteristics of scintillator and performance of detector were shown for the NaI detector. Future development of photon pulse detectors was discussed. (T. Tanaka)

  11. Magazine Coverage of Child Sexual Abuse, 1992-2004

    Science.gov (United States)

    Cheit, Ross E.; Shavit, Yael; Reiss-Davis, Zachary

    2010-01-01

    This article analyzes trends in the coverage of child sexual abuse in popular magazines since the early 1990s. The article employs systematic analysis to identify and analyze articles in four popular magazines. Articles are analyzed by subject, length, and publication. The results affirm established theories of newsworthiness related to the…

  12. Financial incentives and coverage of child health interventions: a systematic review and meta-analysis.

    Science.gov (United States)

    Bassani, Diego G; Arora, Paul; Wazny, Kerri; Gaffey, Michelle F; Lenters, Lindsey; Bhutta, Zulfiqar A

    2013-01-01

    Financial incentives are widely used strategies to alleviate poverty, foster development, and improve health. Cash transfer programs, microcredit, user fee removal policies and voucher schemes that provide direct or indirect monetary incentives to households have been used for decades in Latin America, Sub-Saharan Africa, and more recently in Southeast Asia. Until now, no systematic review of the impact of financial incentives on coverage and uptake of health interventions targeting children under 5 years of age has been conducted. The objective of this review is to provide estimates on the effect of six types of financial incentive programs: (i) Unconditional cash transfers (CT), (ii) Conditional cash transfers (CCT), (iii) Microcredit (MC), (iv) Conditional Microcredit (CMC), (v) Voucher schemes (VS) and (vi) User fee removal (UFR) on the uptake and coverage of health interventions targeting children under the age of five years. We conducted systematic searches of a series of databases until September 1st, 2012, to identify relevant studies reporting on the impact of financial incentives on coverage of health interventions and behaviors targeting children under 5 years of age. The quality of the studies was assessed using the CHERG criteria. Meta-analyses were undertaken to estimate the effect when multiple studies meeting our inclusion criteria were available. Our searches resulted in 1671 titles identified 25 studies reporting on the impact of financial incentive programs on 5 groups of coverage indicators: breastfeeding practices (breastfeeding incidence, proportion of children receiving colostrum and early initiation of breastfeeding, exclusive breastfeeding for six months and duration of breastfeeding); vaccination (coverage of full immunization, partial immunization and specific antigens); health care use (seeking healthcare when child was ill, visits to health facilities for preventive reasons, visits to health facilities for any reason, visits for health

  13. Spatial heterogeneity study of vegetation coverage at Heihe River Basin

    Science.gov (United States)

    Wu, Lijuan; Zhong, Bo; Guo, Liyu; Zhao, Xiangwei

    2014-11-01

    Spatial heterogeneity of the animal-landscape system has three major components: heterogeneity of resource distributions in the physical environment, heterogeneity of plant tissue chemistry, heterogeneity of movement modes by the animal. Furthermore, all three different types of heterogeneity interact each other and can either reinforce or offset one another, thereby affecting system stability and dynamics. In previous studies, the study areas are investigated by field sampling, which costs a large amount of manpower. In addition, uncertain in sampling affects the quality of field data, which leads to unsatisfactory results during the entire study. In this study, remote sensing data is used to guide the sampling for research on heterogeneity of vegetation coverage to avoid errors caused by randomness of field sampling. Semi-variance and fractal dimension analysis are used to analyze the spatial heterogeneity of vegetation coverage at Heihe River Basin. The spherical model with nugget is used to fit the semivariogram of vegetation coverage. Based on the experiment above, it is found, (1)there is a strong correlation between vegetation coverage and distance of vegetation populations within the range of 0-28051.3188m at Heihe River Basin, but the correlation loses suddenly when the distance greater than 28051.3188m. (2)The degree of spatial heterogeneity of vegetation coverage at Heihe River Basin is medium. (3)Spatial distribution variability of vegetation occurs mainly on small scales. (4)The degree of spatial autocorrelation is 72.29% between 25% and 75%, which means that spatial correlation of vegetation coverage at Heihe River Basin is medium high.

  14. Detection alpha particles and Cf-252 fission fragments with track solid detectors and with surface barrier detectors: efficiency determination

    International Nuclear Information System (INIS)

    Khouri, M.T.F.C.; Koskinas, M.F.; Andrade, C. de; Vilela, E.C.; Hinostroza, H.; Kaschiny, J.R.A.; Costa, M.S. da; Rizzo, P.; Santos, W.M.S.

    1990-01-01

    The technique of particle detection by solid track detectors, types of developing and analysis of results are presented. Efficiency measurements of alpha particle detection with Makrofol e and surface barrier detector are made. Detection of Cf-252 fission fragments is shown. (L.C.)

  15. Analysis of metalaxyl racemate using high performance liquid chromatography coupled with four kinds of detectors.

    Science.gov (United States)

    Chen, Tao; Fan, Jun; Gao, Ruiqi; Wang, Tai; Yu, Ying; Zhang, Weiguang

    2016-10-07

    Chiral stationary phase-high performance liquid chromatography coupled with various detectors has been one of most commonly used methods for analysis and separation of chiral compounds over the past decades. Various detectors exhibit different characteristics in qualitative and quantitative studies under different chromatographic conditions. Herein, a comparative evaluation of HPLC coupled with ultraviolet, optical rotation, refractive index, and evaporative light scattering detectors has been conducted for qualitative and quantitative analyses of metalaxyl racemate. Effects of separation conditions on the peak area ratio between two enantiomers, including sample concentration, column temperature, mobile phase composition, as well as flow rate, have been investigated in detail. In addition, the limits of detection, the limits of quantitation, quantitative range and precision for these two enantiomers by using four detectors have been also studied. As indicated, the chromatographic separation conditions have been slight effects on ultraviolet and refractive index detections and the peak area ratio between two enantiomers remains almost unchanged, but the evaporative light scattering detection has been significantly affected by the above-mentioned chromatographic conditions and the corresponding peak area ratios varied greatly. Moreover, the limits of detection, the limits of quantitation, and the quantitative ranges of two enantiomers with UV detection were remarkably lower by 1-2 magnitudes than the others. Copyright © 2016 Elsevier B.V. All rights reserved.

  16. Subnanogram proteomics: Impact of LC column selection, MS instrumentation and data analysis strategy on proteome coverage for trace samples

    Energy Technology Data Exchange (ETDEWEB)

    Zhu, Ying; Zhao, Rui; Piehowski, Paul D.; Moore, Ronald J.; Lim, Sujung; Orphan, Victoria J.; Paša-Tolić, Ljiljana; Qian, Wei-Jun; Smith, Richard D.; Kelly, Ryan T.

    2018-04-01

    One of the greatest challenges for mass spectrometry (MS)-based proteomics is the limited ability to analyze small samples. Here we investigate the relative contributions of liquid chromatography (LC), MS instrumentation and data analysis methods with the aim of improving proteome coverage for sample sizes ranging from 0.5 ng to 50 ng. We show that the LC separations utilizing 30-µm-i.d. columns increase signal intensity by >3-fold relative to those using 75-µm-i.d. columns, leading to 32% increase in peptide identifications. The Orbitrap Fusion Lumos mass spectrometer significantly boosted both sensitivity and sequencing speed relative to earlier generation Orbitraps (e.g., LTQ-Orbitrap), leading to a ~3× increase in peptide identifications and 1.7× increase in identified protein groups for 2 ng tryptic digests of bacterial lysate. The Match Between Runs algorithm of open-source MaxQuant software further increased proteome coverage by ~ 95% for 0.5 ng samples and by ~42% for 2 ng samples. The present platform is capable of identifying >3000 protein groups from tryptic digestion of cell lysates equivalent to 50 HeLa cells and 100 THP-1 cells (~10 ng total proteins), respectively, and >950 proteins from subnanogram bacterial and archaeal cell lysates. The present ultrasensitive LC-MS platform is expected to enable deep proteome coverage for subnanogram samples, including single mammalian cells.

  17. Prospects for Environmental Communication Based on 25 Years of Newspaper Coverage of Climate Change and Eutrophication in Finland

    Science.gov (United States)

    Lyytimäki, Jari

    2015-01-01

    Research on long-term media coverage of environmental issues has focused predominantly on English-speaking industrialized countries and on single isolated topics. This article presents a comparative analysis of the Finnish newspaper coverage of climate change and eutrophication from 1990-2014. The coverage of eutrophication showed an annual cycle…

  18. Fukushima effects in Germany? Changes in media coverage and public opinion on nuclear power.

    Science.gov (United States)

    Arlt, Dorothee; Wolling, Jens

    2016-10-01

    Based on a literature review on factors that explain media effects and previous findings on media coverage and public opinion on nuclear power, this article examines the effects of Fukushima on media coverage and public opinion in Germany in two studies. The first study uses content analysis data to analyse changes in media coverage, and the second one is based on panel survey data to examine attitude changes on an individual level. The results of both studies show changes in media coverage and public opinion on nuclear power. Furthermore, the second study reveals that individual attitude changes cannot necessarily be explained by the same factors as the distribution of attitudes. © The Author(s) 2015.

  19. The forward detector of the ANKE spectrometer. Tracking system and its use in data analysis

    International Nuclear Information System (INIS)

    Dymov, S.; Erven, W.; Kacharava, A.

    2004-01-01

    The tracking system of the forward detector of the ANKE magnetic spectrometer at the internal beam of the accelerator COSY (Juelich, Germany) is described. Data analysis procedures, including track search and momentum reconstruction, are presented, and the performance of the tracking system is illustrated with the use of experimental data

  20. Evolution of Rape Myths and Sexual Assaults in Newspaper Coverage

    Directory of Open Access Journals (Sweden)

    Yan-Wen Tsai

    2016-07-01

    Full Text Available The article presents an analysis of the coverage of three newspapers of rape in the daily Press in Taiwan. The idea that rape is a sexual rather than an aggressive act encourages people not to take it seriously as a crime-an attitude frequently revealed in comments by defense attorneys and newspaper. The authors’ investigated that the female victim who did not know most of her attackers will be portrayed as helpless and not responsible for her victimization. The newspapers sustained and reinforced the myths that a woman who is having consensual sex cannot be raped, and if so, she is held culpable and perceived as “asking for it.” A content analysis of newspapers’ headlines and coverage between 2002 and 2013 showed that more than 50% endorsed a rape myth.

  1. Transmutation detectors

    Energy Technology Data Exchange (ETDEWEB)

    Viererbl, L., E-mail: vie@ujv.c [Research Centre Rez Ltd. (Czech Republic); Nuclear Research Institute Rez plc (Czech Republic); Lahodova, Z. [Research Centre Rez Ltd. (Czech Republic); Nuclear Research Institute Rez plc (Czech Republic); Klupak, V. [Nuclear Research Institute Rez plc (Czech Republic); Sus, F. [Research Centre Rez Ltd. (Czech Republic); Nuclear Research Institute Rez plc (Czech Republic); Kucera, J. [Research Centre Rez Ltd. (Czech Republic); Nuclear Physics Institute, Academy of Sciences of the Czech Republic (Czech Republic); Kus, P.; Marek, M. [Research Centre Rez Ltd. (Czech Republic); Nuclear Research Institute Rez plc (Czech Republic)

    2011-03-11

    We have designed a new type of detectors, called transmutation detectors, which can be used primarily for neutron fluence measurement. The transmutation detector method differs from the commonly used activation detector method in evaluation of detector response after irradiation. Instead of radionuclide activity measurement using radiometric methods, the concentration of stable non-gaseous nuclides generated by transmutation in the detector is measured using analytical methods like mass spectrometry. Prospective elements and nuclear reactions for transmutation detectors are listed and initial experimental results are given. The transmutation detector method could be used primarily for long-term measurement of neutron fluence in fission nuclear reactors, but in principle it could be used for any type of radiation that can cause transmutation of nuclides in detectors. This method could also be used for measurement in accelerators or fusion reactors.

  2. Transmutation detectors

    International Nuclear Information System (INIS)

    Viererbl, L.; Lahodova, Z.; Klupak, V.; Sus, F.; Kucera, J.; Kus, P.; Marek, M.

    2011-01-01

    We have designed a new type of detectors, called transmutation detectors, which can be used primarily for neutron fluence measurement. The transmutation detector method differs from the commonly used activation detector method in evaluation of detector response after irradiation. Instead of radionuclide activity measurement using radiometric methods, the concentration of stable non-gaseous nuclides generated by transmutation in the detector is measured using analytical methods like mass spectrometry. Prospective elements and nuclear reactions for transmutation detectors are listed and initial experimental results are given. The transmutation detector method could be used primarily for long-term measurement of neutron fluence in fission nuclear reactors, but in principle it could be used for any type of radiation that can cause transmutation of nuclides in detectors. This method could also be used for measurement in accelerators or fusion reactors.

  3. Updating Coverage of Operant Conditioning in Introductory Psychology.

    Science.gov (United States)

    Buskist, William; Miller, Erin; Ecott, Cheryl; Critchfield, Thomas S.

    1999-01-01

    Offers an example of determining what the experts of psychology deem as essential concepts in their subfield by investigating the current principles in operant conditioning through surveys of the board of editors of the "Journal of the Experimental Analysis of Behavior." Recommends concepts that are appropriate for up-to-date coverage of operant…

  4. Health insurance coverage and impact: a survey in three cities in China.

    Science.gov (United States)

    Fang, Kuangnan; Shia, BenChang; Ma, Shuangge

    2012-01-01

    China has one of the world's largest health insurance systems, composed of government-run basic health insurance and commercial health insurance. The basic health insurance has undergone system-wide reform in recent years. Meanwhile, there is also significant development in the commercial health insurance sector. A phone call survey was conducted in three major cities in China in July and August, 2011. The goal was to provide an updated description of the effect of health insurance on the population covered. Of special interest were insurance coverage, gross and out-of-pocket medical cost and coping strategies. Records on 5,097 households were collected. Analysis showed that smaller households, higher income, lower expense, presence of at least one inpatient treatment and living in rural areas were significantly associated with a lower overall coverage rate. In the separate analysis of basic and commercial health insurance, similar factors were found to have significant associations. Higher income, presence of chronic disease, presence of inpatient treatment, higher coverage rates and living in urban areas were significantly associated with higher gross medical cost. A similar set of factors were significantly associated with higher out-of-pocket cost. Households with lower income, inpatient treatment, higher commercial insurance coverage, and living in rural areas were significantly more likely to pursue coping strategies other than salary. The surveyed cities and surrounding rural areas had socioeconomic status far above China's average. However, there was still a need to further improve coverage. Even for households with coverage, there was considerable out-of-pocket medical cost, particularly for households with inpatient treatments and/or chronic diseases. A small percentage of households were unable to self-finance out-of-pocket medical cost. Such observations suggest possible targets for further improving the health insurance system.

  5. Handoff Rate and Coverage Analysis in Multi-tier Heterogeneous Networks

    OpenAIRE

    Sadr, Sanam; Adve, Raviraj S.

    2015-01-01

    This paper analyzes the impact of user mobility in multi-tier heterogeneous networks. We begin by obtaining the handoff rate for a mobile user in an irregular cellular network with the access point locations modeled as a homogeneous Poisson point process. The received signal-to-interference-ratio (SIR) distribution along with a chosen SIR threshold is then used to obtain the probability of coverage. To capture potential connection failures due to mobility, we assume that a fraction of handoff...

  6. The posterior thigh flap for defect coverage of ischial pressure sores - a critical single-centre analysis.

    Science.gov (United States)

    Djedovic, Gabriel; Morandi, Evi M; Metzler, Julia; Wirthmann, Anna; Matiasek, Johannes; Bauer, Thomas; Rieger, Ulrich M

    2017-12-01

    The development of pressure sores is still not only an enormous economical but also a medical burden. Especially in the ischial region, the local defect coverage remains demanding as it is the main weight-bearing area in wheelchair-mobilised patients and is prone to high mobility. The purpose of our study was to report our long-time experience with the reconstruction of ischial pressure ulcers with the medially based posterior thigh flap. A retrospective analysis of all primary pressure sores grade III-IV in the ischial area, which were covered with a medially based posterior thigh flap between January 2008 and December 2014, at our department was conducted. A total of 28 patients underwent defect coverage of an ischial pressure sore with the aforementioned flap. The subgroup with complications showed a statistically significant longer hospital stay. A statistically significant correlation between age and the coincidence of comorbidities could be seen. Older patients showed significantly higher grades of pressure sores. The medially based posterior thigh flap is a safe and reliable flap design. Complication rates are comparable to other flaps. Nevertheless, in case of complications, a significantly longer duration of hospitalisation has to be taken into account. © 2017 Medicalhelplines.com Inc and John Wiley & Sons Ltd.

  7. The PANDA detector and its physics program at FAIR

    International Nuclear Information System (INIS)

    Brinkmann, K.

    2005-01-01

    The PANDA detector will make use of the antiprotons produced in the FAIR complex and stored in the High-Energy Storage Ring HESR for the study of strong interactions in antiproton collisions with protons and heavy targets. The detector features a 4π design for charged particles with a solenoidal magnetic field and full coverage of photons by means of an advanced electromagnetic calorimeter. In addition, a dipole spectrometer will allow high-resolution detection of leading particles characteristic for fixed-target experiments. The physics program of PANDA covers a wide range of topics which address central issues of QCD at low and moderate energies. Spectroscopy of hidden charm in the ccbar level scheme is still a very interesting issue, in particular when states are involved which cannot directly be formed in e + e - reactions. Open charm in the D meson section has recently received renewed interest when states were discovered that are not easily explained in conventional qqbar models. Exotic hadrons and glueballs have been predicted by theory within the energy range covered by PANDA. The search for these and the eventual study of their properties is central to the physics program. Using heavy targets, PANDA intends to study the properties of charm quarks in the hadronic medium. The copious production of baryon-antibaryon pairs at HESR will allow studies using secondary targets for the formation of hypernuclei. Each of these physics topics will be touched while the detector properties needed in order to cover the broad physics program are described. Technical developments and the status of the various detector components will be summarized

  8. Prevalence, Characteristics, and Perception of Nursery Antibiotic Stewardship Coverage in the United States.

    Science.gov (United States)

    Cantey, Joseph B; Vora, Niraj; Sunkara, Mridula

    2017-09-01

    Prolonged or unnecessary antibiotic use is associated with adverse outcomes in infants. Antibiotic stewardship programs (ASPs) aim to prevent these adverse outcomes and optimize antibiotic prescribing. However, data evaluating ASP coverage of nurseries are limited. The objectives of this study were to describe the characteristics of nurseries with and without ASP coverage and to determine perceptions of and barriers to nursery ASP coverage. The 2014 American Hospital Association annual survey was used to randomly select a level III neonatal intensive care unit from all 50 states. A level I and level II nursery from the same city as the level III nursery were then randomly selected. Hospital, nursery, and ASP characteristics were collected. Nursery and ASP providers (pharmacists or infectious disease providers) were interviewed using a semistructured template. Transcribed interviews were analyzed for themes. One hundred forty-six centers responded; 104 (71%) provided nursery ASP coverage. In multivariate analysis, level of nursery, university affiliation, and number of full-time equivalent ASP staff were the main predictors of nursery ASP coverage. Several themes were identified from interviews: unwanted coverage, unnecessary coverage, jurisdiction issues, need for communication, and a focus on outcomes. Most providers had a favorable view of nursery ASP coverage. Larger, higher-acuity nurseries in university-affiliated hospitals are more likely to have ASP coverage. Low ASP staffing and a perceived lack of importance were frequently cited as barriers to nursery coverage. Most nursery ASP coverage is viewed favorably by providers, but nursery providers regard it as less important than ASP providers. © The Author 2016. Published by Oxford University Press on behalf of the Pediatric Infectious Diseases Society. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.

  9. CFAR Edge Detector for Polarimetric SAR Images

    DEFF Research Database (Denmark)

    Schou, Jesper; Skriver, Henning; Nielsen, Allan Aasbjerg

    2003-01-01

    Finding the edges between different regions in an image is one of the fundamental steps of image analysis, and several edge detectors suitable for the special statistics of synthetic aperture radar (SAR) intensity images have previously been developed. In this paper, a new edge detector for polar...

  10. Detector Control System for the ATLAS Forward Proton detector

    CERN Document Server

    Czekierda, Sabina; The ATLAS collaboration

    2017-01-01

    The ATLAS Forward Proton (AFP) is a forward detector using a Roman Pot technique, recently installed in the LHC tunnel. It is aiming at registering protons that were diffractively or electromagnetically scattered in soft and hard processes. Infrastructure of the detector consists of hardware placed both in the tunnel and in the control room USA15 (about 330 meters from the Roman Pots). AFP detector, like the other detectors of the ATLAS experiment, uses the Detector Control System (DCS) to supervise the detector and to ensure its safe and coherent operation, since the incorrect detector performance may influence the physics results. The DCS continuously monitors the detector parameters, subset of which is stored in data bases. Crucial parameters are guarded by alarm system. A detector representation as a hierarchical tree-like structure of well-defined subsystems built with the use of the Finite State Machine (FSM) toolkit allows for overall detector operation and visualization. Every node in the hierarchy is...

  11. Analysis of monochromatic signals by using data from the detector of Allegro gravitational waves

    International Nuclear Information System (INIS)

    Oliveira, Fernanda Gomes de

    2010-01-01

    The present work is developed in the searching for monochromatic gravitational waves signals in ALLEGRO's data. We have two procedures for data analysis based on the periodogram of Welch, which a method for the detection of monochromatic signals in the middle of noise which basically makes power spectrum estimates using averaged modified periodograms. By using this method it was possible to obtain a power spectrum for the data which reinforce peaks due to monochromatic signals. The two procedures of analysis for the years 1997 and 1999, were focused on monitoring a peak that appears in the spectral density of ALLEGRO's detector, so called 'mystery mode' (near 887 Hz). We look for variations in the frequency of the mystery mode that agree with the variation of the Doppler effect. In the rst analysis we have used by the variation of daily and annual Doppler shift. For the second one, we have only searched annual Doppler shift. We have applied the periodogram of Welch in both tests in the raw data of the detector in the search for a real signal and we found some peaks that can be candidates of gravitational radiation only the second analysis. In order to test the method we used in both analysis a simulated gravitational wave signal modulated by the Doppler effect injected in the data. We detected in both methods the artificial signal of GW simulated. Therefore we have reason to conclude that both methods are efficient in the search for monochromatic signals. (author)

  12. Resolution limits achievable with CMOS front-end in X- and γ-ray analysis with semiconductor detectors

    International Nuclear Information System (INIS)

    Manfredi, P.F.; Manghisoni, M.; Ratti, L.; Re, V.; Speziali, V.

    2003-01-01

    During the past 15 years, the CMOS technologies have provided the most widely followed approach to signal processing with microstrip detectors. In more recent times, CMOS front-end systems have been developed to acquire and process signals from pixel detectors. During the past few years, the favor toward CMOS processes in their applications in the broad area of detector signal processing has been enhanced by the technological advancement known as device scaling and by two aspects connected to it. One is the shrinking in channel length L into the deep submicron region. The second one is the related reduction in the gate-oxide thickness t ox to a few nm. The reduction in t ox has, as a consequence of primary importance, a decreased 1/f-noise contribution to the equivalent noise charge (ENC). The thinner gate-oxide and the shrinking in gate length, in some regions of operations, concur to increase the transconductance of the device, which results in a smaller ENC contribution from channel thermal noise. The goal of the present paper is to address the question of whether or not the most advanced CMOS processes may meet the requirements set by high resolution, high dynamic range applications like the energy-dispersive photon analysis with solid-state detectors of comparatively large capacitance

  13. Lithium analysis using a double-sided silicon strip detector at LIBAF

    Science.gov (United States)

    De La Rosa, Nathaly; Kristiansson, Per; Nilsson, E. J. Charlotta; Ros, Linus; Elfman, Mikael; Pallon, Jan

    2017-08-01

    Quantification and mapping possibilities of lithium in geological material, by Nuclear Reaction Analysis (NRA), was evaluated at the Lund Ion Beam Analysis Facility (LIBAF). LiF and two Standard Reference Materials, (SRM 610 and SRM 612) were used in the investigation. The main part of the data was obtained at the beam energy 635 keV studying the high Q-value reaction 7Li(p, α)4He, but reaction yield and detection limits were also briefly investigated as a function of the energy. A double-sided silicon strip detector (DSSSD) was used to detect the α -particles emitted in the reaction in the backward direction. The combination of the high Q-value, a reasonably good cross-section and the possibility to use a high beam current have been demonstrated to allow for measurement of concentrations down below 50 ppm. Proton energies below 800 keV were demonstrated to be appropriate energies for extracting lithium in combination with boron analysis.

  14. Fast simulation of the forward tracking detector of HPLUS

    International Nuclear Information System (INIS)

    Zhang Yapeng; Fan Ruirui; Fu Fen; Yue Ke; Yuan Xiaohua; Xu Huagen; Chinese Academy of Sciences, Beijing; Yao Nan; Xu Hushan; Jin Genming; Liang Jinjie; Chen Ruofu; Sun Zhiyu; Duan Limin; Xiao Zhigang; Tsinghua Univ., Beijing

    2008-01-01

    The necessity of installing a forward tracking detector stack is discussed for the Hadron Physics Lanzhou Spectrometer(HPLUS). A local tracker is developed to solve the multi-track finding problem. The track candidates are searched iteratively via Hough Transform. The fake tracks are removed by a least square fitting process. With this tracker we have studied the feasibility of pp→pp+φ(→K + K - ), a typical physical channel proposed on HPLUS. The single track momentum resolution due to the uncertainty of the positioning in FTD is 1.3%. The multiple scattering effect contributes about 20% to the momentum resolution in the FTD coverage. The width and the signal-to-background ratio of the reconstructed φ are 1.51 MeV and 4.36, respectively, taking into account the direct Kaon channel pp→pp+K + K - as background. The geometry coverage of FTD for qb events is about 85.4%. Based on the current fast simulation and estimation, the geometrical configuration of FTD meets the physical requirement of HPLUS under the current luminosity and multiplicity conditions. The tracker is applicable in the full simulation coming next and is extendable to other tracking component of HPLUS. (authors)

  15. Neutron activation analysis of uranium by means of electrochemical etching of tracks in lawsan detectors

    International Nuclear Information System (INIS)

    Kim Son Chun; Chuburkov, Yu.T.; Zvara, I.I.

    1982-01-01

    The method of neutron activation analysis of uranium in natural and artificial materials using track lavsan detectors of fission fragments has been developed. The method of electrochemical etching (etching reagent NaOH) of fragment tracks in lavsan is improved. Using statistical method of experiment planning the equation, describing the dependence of diometer value of fission fragment tracks on parameters of etching process, is obtained. The analysis sensitivity is 10 - 7 g/g - 10 - 8 g/g

  16. Root coverage procedures improve patient aesthetics. A systematic review and Bayesian network meta-analysis.

    Science.gov (United States)

    Cairo, Francesco; Pagliaro, Umberto; Buti, Jacopo; Baccini, Michela; Graziani, Filippo; Tonelli, Paolo; Pagavino, Gabriella; Tonetti, Maurizio S

    2016-11-01

    The aim of this study was to perform a systematic review (SR) of randomized controlled trials (RCTs) to explore if periodontal plastic surgery procedures for the treatment of single and multiple gingival recessions (Rec) may improve aesthetics at patient and professional levels. In order to combine evidence from direct and indirect comparisons by different trials a Bayesian network meta-analysis (BNM) was planned. A literature search on PubMed, Cochrane libraries, EMBASE, and hand-searched journals until January 2016 was conducted to identify RCTs presenting aesthetic outcomes after root coverage using standardized evaluations at patient and professional level. A total of 16 RCTs were selected in the SR; three RTCs presenting professional aesthetic evaluation with Root coverage Aesthetic Score (RES) and three showing final self-perception using the Visual Analogue Scale (VAS Est) could be included in a BNM model. Coronally Advanced Flap plus Connective Tissue Graft (CAF + CTG) and CAF + Acellular Dermal Matrix (ADM) and Autologous Fibroblasts (AF) were associated with the best RES outcomes (best probability = 24% and 64%, respectively), while CAF + CTG and CAF + CTG + Enamel matrix Derivatives (EMD) obtained highest values of VAS Est score (best probability = 44% and 26%, respectively). Periodontal Plastic Surgery (PPS) techniques applying grafts underneath CAF with or without the adding of EMD are associated with improved aesthetics assessed by final patient perception and RES as professional evaluation system. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  17. Electronic and postal reminders for improving immunisation coverage in children: protocol for a systematic review and meta-analysis.

    Science.gov (United States)

    Chachou, Martel J; Mukinda, Fidele K; Motaze, Villyen; Wiysonge, Charles S

    2015-10-15

    Worldwide, suboptimal immunisation coverage causes the deaths of more than one million children under five from vaccine-preventable diseases every year. Reasons for suboptimal coverage are multifactorial, and a combination of interventions is needed to improve compliance with immunisation schedules. One intervention relies on reminders, where the health system prompts caregivers to attend immunisation appointments on time or re-engages caregivers who have defaulted on scheduled appointments. We undertake this systematic review to investigate the potential of reminders using emails, phone calls, social media, letters or postcards to improve immunisation coverage in children under five. We will search for published and unpublished randomised controlled trials and non-randomised controlled trials in PubMed, Scopus, CINAHL, CENTRAL, Science Citation Index, WHOLIS, Clinicaltrials.gov and the WHO International Clinical Trials Platform. We will conduct screening of search results, study selection, data extraction and risk-of-bias assessment in duplicate, resolving disagreements by consensus. In addition, we will pool data from clinically homogeneous studies using random-effects meta-analysis; assess heterogeneity of effects using the χ(2) test of homogeneity; and quantify any observed heterogeneity using the I(2) statistic. This protocol does not need approval by an ethics committee because we will use publicly available data, without directly involving human participants. The results will provide updated evidence on the effects of electronic and postal reminders on immunisation coverage, and we will discuss the applicability of the findings to low and middle-income countries. We plan to disseminate review findings through publication in a peer-reviewed journal and presentation at relevant conferences. In addition, we will prepare a policymaker-friendly summary using a validated format (eg, SUPPORT Summary) and disseminate this through social media and email discussion

  18. Detection of alpha particles and Cf-252 fission fragments with solid track detectors and surface barrier detector. Efficiency calculation

    International Nuclear Information System (INIS)

    Khouri, M.T.F.C.; Koskinas, M.F.; Andrade, C. de; Vilela, E.C.; Hinostroza, H.; Kaschiny, J.E.A.; Costa, M.S. da; Rizzo, P.; Santos, W.M.S.

    1990-01-01

    A technique for particle detection by using track solid detector and also types of revealing and result analysis are presented concerned to Cf-252 fission fragments detection. Measurements of alpha particles detection efficiency using Makrofol E and surface barrier detector are performed. (L.C.J.A.)

  19. Percent Coverage

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The Percent Coverage is a spreadsheet that keeps track of and compares the number of vessels that have departed with and without observers to the numbers of vessels...

  20. Ultra high resolution X-ray detectors

    International Nuclear Information System (INIS)

    Hess, U.; Buehler, M.; Hentig, R. von; Hertrich, T.; Phelan, K.; Wernicke, D.; Hoehne, J.

    2001-01-01

    CSP Cryogenic Spectrometers GmbH is developing cryogenic energy dispersive X-ray spectrometers based on superconducting detector technology. Superconducting sensors exhibit at least a 10-fold improvement in energy resolution due to their low energy gap compared to conventional Si(Li) or Ge detectors. These capabilities are extremely valuable for the analysis of light elements and in general for the analysis of the low energy range of the X-ray spectrum. The spectrometer is based on a mechanical cooler needing no liquid coolants and an adiabatic demagnetization refrigerator (ADR) stage which supplies the operating temperature of below 100 mK for the superconducting sensor. Applications include surface analysis in semiconductor industry as well material analysis for material composition e.g. in ceramics or automobile industry

  1. The noise analysis and optimum filtering techniques for a two-dimensional position sensitive orthogonal strip gamma ray detector employing resistive charge division

    International Nuclear Information System (INIS)

    Gerber, M.S.; Muller, D.W.

    1976-01-01

    The analysis of an orthogonal strip, two-dimensional position sensitive high purity germanium gamma ray detector is discussed. Position sensitivity is obtained by connecting each electrode strip on the detector to a resistor network. Charge, entering the network, divides in relation to the resistance between its entry point and the virtual earth points of the charge sensitive preamplifiers located at the end of each resistor network. The difference of the voltage pulses at the output of each preamplifier is proportional to the position at which the charge entered the resistor network and the sum of the pulse is proportional to the energy of the detected gamma ray. The analysis and spatial noise resolution is presented for this type of position sensitive detector. The results of the analysis show that the position resolution is proportional to the square root of the filter amplifier's output pulse time constant and that for energy measurement the resolution is maximized at the filter amplifier's noise corner time constant. The design of the electronic noise filtering system for the prototype gamma ray camera was based on the mathematical energy and spatial resolution equations. For the spatial channel a Gaussian trapezoidal filtering system was developed. Gaussian filtering was used for the energy channel. The detector noise model was verified by taking rms noise measurements of the filtered energy and spatial pulses from resistive readout charge dividing detectors. These measurements were within 10% of theory. (Auth.)

  2. Measurement of two-phase flow variables in a BWR by analysis of in-core neutron detector noise signals

    International Nuclear Information System (INIS)

    Stekelenburg, A.J.C.; Hagen, T.H.J.J. van der

    1996-01-01

    In this paper, the state of the art of the measurement of two-phase flow variables in a boiling water reactor (BWR) by analysis of in-core neutron detector noise signals is given. It is concluded that the neutronic processes involved in neutron noise are quite well understood, but that little is known about the density fluctuations in two-phase flow which are the main cause of the neutron noise. For this reason, the neutron noise measurements, like the well known two-detector velocity measurements, are still difficult to interpret. By analyzing neutron noise measurements in a natural circulation cooled BWR, it is illustrated that, once a theory on the density fluctuations is developed, two-phase flow can be monitored with a single in-core detector. (author). 70 refs, 4 figs

  3. Calibration of detector efficiency of neutron detector

    International Nuclear Information System (INIS)

    Guo Hongsheng; He Xijun; Xu Rongkun; Peng Taiping

    2001-01-01

    BF 3 neutron detector has been set up. Detector efficiency is calibrated by associated particle technique. It is about 3.17 x 10 -4 (1 +- 18%). Neutron yield of neutron generator per pulse (10 7 /pulse) is measured by using the detector

  4. Analysis and modelling of the performance of a new solid-state detector in nuclear medicine: from Anger- to Semiconductor-detectors

    International Nuclear Information System (INIS)

    Imbert, L.

    2012-01-01

    Myocardial single-photon emission computed tomography (SPECT) is considered as the gold standard for the diagnosis of coronary artery disease. Developed in the 1980's with rotating Anger gamma cameras, this technique could be dramatically enhanced by new imaging systems working with semiconductor detectors and which performances are clearly enhanced. Two semiconductor cameras, dedicated to nuclear cardiology and equipped with Cadmium Zinc Telluride detectors, have been recently commercialized: the Discovery NM- 530c (General Electric) and the DSPECT (Spectrum Dynamics). The performances of these CZT cameras were compared: 1) by a comprehensive analysis of phantom and human SPECT images considered as normal and 2) with the parameters commonly recommended for SPECT recording and reconstruction. The results show the superiority of the CZT cameras in terms of detection sensitivity, spatial resolution and contrast-to-noise ratio, compared to conventional Anger cameras. These properties might lead to dramatically reduce acquisition times and/or the injected activities. However, the limits of these new CZT cameras, as well as the mechanism of certain artefacts, remain poorly known. This knowledge could be enhanced by a numerical modeling of the DSPECT camera, and this might also help to optimize acquisition and reconstruction parameters. We developed a simulator where the geometry of the detectors of the DSPECT camera and their energy response were modeled in the GATE platform. In order to validate this simulator, actually recorded data were compared with simulated data through three performance parameters: detection sensitivity, spatial resolution and energy resolution. Results were in agreement between simulated and actually recorded data. This observation validates the DSPECT simulator and opens the door to further studies planed to optimize the recorded and reconstruction processes, especially for complex protocols such as simultaneous dual-radionuclide acquisition

  5. Fabrication and utilization of semiconductor radiation detectors

    International Nuclear Information System (INIS)

    Lemos Junior, Orlando Ferreira

    1969-01-01

    This paper describes the assembly of the equipment for the fabrication of Ge-Li drifted detectors and the technique used in the preparation of a Planar detector of 7 cm 2 x 0,5 cm for the Laboratory of the Linear Accelerator at the University of Sao Paulo, as well as the utilization of a 22 cm 3 coaxial detector for the analysis of fission product gamma rays at the Instituto de Engenharia Nuclear, Rio de Janeiro, R J, Brazil. (author)

  6. A large solid angle multiparameter neutron detector

    International Nuclear Information System (INIS)

    Ricco, G.; Anghinolfi, M.; Corvisiero, P.; Durante, E.; Maggiolo, S.; Prati, P.; Rottura, A.; Taiuti, M.

    1991-01-01

    A 4π neutron detector has been realized using organic scintillators: the detector is suitable for high efficiency, low background measurements of very low neutron rates in the 0.6-5 MeV energy range. Gamma-neutron discrimination has been performed by pulse shape, energy and neutron lifetime analysis and backgrounds have been reduced by anticoincidence detectors and paraffin-lead shielding. Tests of efficiency, energy resolution and radiation identification have been made with a low intensity Am-Be neutron source. (orig.)

  7. Medicaid Coverage for Methadone Maintenance and Use of Opioid Agonist Therapy in Specialty Addiction Treatment.

    Science.gov (United States)

    Saloner, Brendan; Stoller, Kenneth B; Barry, Colleen L

    2016-06-01

    This study examined differences in opioid agonist therapy (OAT) utilization among Medicaid-enrolled adults receiving public-sector opioid use disorder treatment in states with Medicaid coverage of methadone maintenance, states with block grant funding only, and states without public coverage of methadone. Person-level treatment admission data, which included information on reason for treatment and use of OAT from 36 states were linked to state-level Medicaid policies collected in a 50-state survey. Probabilities of OAT use among Medicaid enrollees in opioid addiction treatment were calculated, with adjustment for demographic characteristics and patterns of substance use. In adjusted analysis, 45.0% of Medicaid-enrolled individuals in opioid addiction treatment in states with Medicaid coverage for methadone maintenance used OAT, compared with 30.1% in states with block grant coverage only and 17.0% in states with no coverage. Differences were widest in nonintensive outpatient settings. Medicaid methadone maintenance coverage is critical for encouraging OAT among individuals with opioid use disorders.

  8. Scintillation neutron detector with dynamic threshold

    International Nuclear Information System (INIS)

    Kornilov, N.; Massey, T.; Grimes, S.

    2014-01-01

    Scintillation neutron detectors with hydrogen are a common tool for neutron spectroscopy. They provide good time resolution, neutron-gamma discrimination and high efficiency of neutron counting. The real open problems connected with application of these detectors are in the energy range >10 MeV. There are no standard neutron spectra known with high accuracy for this energy range. Therefore, traditional methods for experimental investigation of the efficiency function fail for these neutrons. The Monte Carlo simulation cannot provide reasonable accuracy due to unknown characteristics of the reactions for charged particle production (p, α and so on, light output, reaction cross-sections). The application of fission chamber with fissile material as a neutron detector did not help to solve the problem. We may avoid many problems if we use the traditional neutron detector with non-traditional data analysis. In this report we give main relations, and demonstrate the method for Cf-source. Experimental detector efficiency is compared with MC simulation. (authors)

  9. Modeling of a Low-Background Spectroscopic Position-Sensitive Neutron Detector

    Energy Technology Data Exchange (ETDEWEB)

    Postovarova, Daria; Evsenin, Alexey; Gorshkov, Igor; Kuznetsov, Andrey; Osetrov, Oleg; Vakhtin, Dmitry; Yurmanov, Pavel [V.G. Khlopin Radium Institute, 194021, 28, 2nd Murinsky pr., Saint-Petersburg (Russian Federation)

    2011-12-13

    A new low-background spectroscopic direction-sensitive neutron detector that would allow one to reduce the neutron background component in passive and active neutron detection techniques is proposed. The detector is based on thermal neutron detectors surrounded by a fast neutron scintillation detector, which serves at the same time as a neutron moderator. Direction sensitivity is achieved by coincidence/anticoincidence analysis between different parts of the scintillator. Results of mathematical modeling of several detector configurations are presented.

  10. Modeling of a Low-Background Spectroscopic Position-Sensitive Neutron Detector

    International Nuclear Information System (INIS)

    Postovarova, Daria; Evsenin, Alexey; Gorshkov, Igor; Kuznetsov, Andrey; Osetrov, Oleg; Vakhtin, Dmitry; Yurmanov, Pavel

    2011-01-01

    A new low-background spectroscopic direction-sensitive neutron detector that would allow one to reduce the neutron background component in passive and active neutron detection techniques is proposed. The detector is based on thermal neutron detectors surrounded by a fast neutron scintillation detector, which serves at the same time as a neutron moderator. Direction sensitivity is achieved by coincidence/anticoincidence analysis between different parts of the scintillator. Results of mathematical modeling of several detector configurations are presented.

  11. Clinical Paresthesia Atlas Illustrates Likelihood of Coverage Based on Spinal Cord Stimulator Electrode Location.

    Science.gov (United States)

    Taghva, Alexander; Karst, Edward; Underwood, Paul

    2017-08-01

    Concordant paresthesia coverage is an independent predictor of pain relief following spinal cord stimulation (SCS). Using aggregate data, our objective is to produce a map of paresthesia coverage as a function of electrode location in SCS. This retrospective analysis used x-rays, SCS programming data, and paresthesia coverage maps from the EMPOWER registry of SCS implants for chronic neuropathic pain. Spinal level of dorsal column stimulation was determined by x-ray adjudication and active cathodes in patient programs. Likelihood of paresthesia coverage was determined as a function of stimulating electrode location. Segments of paresthesia coverage were grouped anatomically. Fisher's exact test was used to identify significant differences in likelihood of paresthesia coverage as a function of spinal stimulation level. In the 178 patients analyzed, the most prevalent areas of paresthesia coverage were buttocks, anterior and posterior thigh (each 98%), and low back (94%). Unwanted paresthesia at the ribs occurred in 8% of patients. There were significant differences in the likelihood of achieving paresthesia, with higher thoracic levels (T5, T6, and T7) more likely to achieve low back coverage but also more likely to introduce paresthesia felt at the ribs. Higher levels in the thoracic spine were associated with greater coverage of the buttocks, back, and thigh, and with lesser coverage of the leg and foot. This paresthesia atlas uses real-world, aggregate data to determine likelihood of paresthesia coverage as a function of stimulating electrode location. It represents an application of "big data" techniques, and a step toward achieving personalized SCS therapy tailored to the individual's chronic pain. © 2017 International Neuromodulation Society.

  12. The WET Coverage - How Well Do We Do?

    Directory of Open Access Journals (Sweden)

    Solheim Jan-Erik

    2003-06-01

    Full Text Available The Whole Earth Telescope collaboration is build solidly on the interest of the participants. One of the goals of the collaboration is to produce a high signal to noise, as continuous as possible, light curve for a selected target. During the nearly 15 years of existence the operation of the network has been based on what the members have been able to provide of local funds for their own participation, in addition to NSF grants to run the headquarters activities. This has led to a very uneven geographical distribution of participating groups and observatories. An analysis of the coverage of some of the last WET runs shows that we still have large holes in the coverage, and this leads to aliasing and loss of precision in our final products.

  13. Coverage and Capacity Analysis of LTE-M and NB-IoT in a Rural Area

    DEFF Research Database (Denmark)

    Lauridsen, Mads; Kovács, István; Mogensen, Preben Elgaard

    2016-01-01

    equipped with either of the newly standardized technologies. The study is made for a site specific network deployment of a Danish operator, and the simulation is calibrated using drive test measurements. The results show that LTE-M can provide coverage for 99.9% of outdoor and indoor devices, if the latter......The 3GPP has introduced the LTE-M and NB-IoT User Equipment categories and made amendments to LTE release 13 to support the cellular Internet of Things. The contribution of this paper is to analyze the coverage probability, the number of supported devices, and the device battery life in networks...... is experiencing 10 dB additional loss. However, for deep indoor users NB-IoT is required and provides coverage for about 95% of the users. The cost is support for more than 10 times fewer devices and a 2-6 times higher device power consumption. Thus both LTE-M and NB-IoT provide extended support for the cellular...

  14. Some aspects of detectors and electronics for x-ray fluorescence analysis

    International Nuclear Information System (INIS)

    Goulding, F.S.

    1976-08-01

    Some of the less recognized and potentially important parameters of the electronics and detectors used in X-ray fluorescence spectrometers are discussed. Detector factors include window (dead-layer) effects, time-dependent background and excess background. Noise parameters of field-effect transistors and time-variant pulse shaping are also discussed

  15. 20 CFR 404.1065 - Self-employment coverage.

    Science.gov (United States)

    2010-04-01

    ... 20 Employees' Benefits 2 2010-04-01 2010-04-01 false Self-employment coverage. 404.1065 Section... INSURANCE (1950- ) Employment, Wages, Self-Employment, and Self-Employment Income Self-Employment § 404.1065 Self-employment coverage. For an individual to have self-employment coverage under social security, the...

  16. News media representations of a common EU foreign and security policy: a cross-national content analysis of CFSP coverage in national quality newspapers

    NARCIS (Netherlands)

    Kandyla, A.-A.; de Vreese, C.

    2011-01-01

    This study is a cross-national comparative content analysis of the broadsheet press coverage of EU Common Foreign and Security issues (n=1453) focusing on the presence of indicators of a European Public Sphere. Specifically, we investigated the visibility of Common Foreign and Security Policy (CFSP)

  17. Coverage and Compliance of Mass Drug Administration in Lymphatic Filariasis: A Comparative Analysis in a District of West Bengal, India

    Directory of Open Access Journals (Sweden)

    Tanmay Kanti Panja

    2012-01-01

    Full Text Available Background: Despite several rounds of Mass Drug Administration (MDA as an elimination strategy of Lymphatic Filariasis (LF from India, still the coverage is far behind the required level of 85%.Objectives: The present study was carried out with the objectives to assess the coverage and compliance of MDA and their possible determinants. Methods: A cross-sectional community based study was conducted in Paschim Midnapur district of West Bengal, India for consecutive two years following MDA. Study participants were chosen by 30-cluster sampling technique. Data was collected by using pre-tested semi-structured proforma to assess the coverage and compliance of MDA along with possible determinants for non-attaining the expected coverage. Results: In the year 2009, coverage, compliance, coverage compliance gap (CCG and effective coverage was seen to be 84.1%, 70.5%, 29.5% and 59.3% respectively. In 2010, the results further deteriorated to 78.5%, 66.9%, 33.3% and 57% respectively. The poor coverage and compliance were attributed to improper training of service providers and lack of community awareness regarding MDA.Conclusion: The study emphasized supervised consumption, retraining of service providers before MDA activities, strengthening behaviour change communication strategy for community awareness. Advocacy by the program managers and policy makers towards prioritization of MDA program will make the story of filaria elimination a success.

  18. Development and test of the CO2 evaporative cooling system for the LHCb UT Detector

    CERN Multimedia

    Coelli, Simone

    2016-01-01

    The upgrade of the LHCb detector, which will take place during the Long Shutdown 2 from mid 2018 to the end of 2019, will extend significantly the physics reach of the experiment by allowing it to run at higher instantaneous luminosity with increased trigger efficiency for a wide range of decay channels. The LHCb upgrade relies on two major changes. Firstly, the full read-out of the front-end electronics, currently limited by a Level-0 trigger to 1 MHz, will be replaced with a 40 MHz trigger system. Secondly, the upgraded LHCb detector will be designed to cope with an increase of the nominal operational luminosity by a factor five compared to the current detector. Compared to the current experiment several subsystems need to be partially rebuilt. Among these the 4 TT planes will be replaced by new high granularity silicon micro-strip planes with an improved coverage of the LHCb acceptance.The new system is called the Upstream Tracker. The radiation length of each UT plane should not exceed the value of 1 % X0...

  19. Assessing Measurement Error in Medicare Coverage

    Data.gov (United States)

    U.S. Department of Health & Human Services — Assessing Measurement Error in Medicare Coverage From the National Health Interview Survey Using linked administrative data, to validate Medicare coverage estimates...

  20. Comparative analysis of the machine repair Problem with imperfect coverage and service pressure condition

    Science.gov (United States)

    Wang, Kuo-Hsiung; Liou, Cheng-Dar; Lin, Yu-Hsueh

    2013-02-01

    We analyze the warm-standby M/M/R machine repair problem with multiple imperfect coverage which involving the service pressure condition. When an operating machine (or warm standby) fails, it may be immediately detected, located, and replaced with a coverage probability c by a standby if one is available. A recursive method is used to develop the steady-state analytic solutions. The total expected profit function per unit time is derived to determine the joint optimal values at the maximum profit. We utilize the direct search method to measure the various characteristics of the profit function followed by Quasi-Newton method to search the optimal solutions.

  1. Pension coverage among the baby boomers: initial findings from a 1993 survey.

    Science.gov (United States)

    Woods, J R

    1994-01-01

    Using data from a series of supplements to the Current Population Survey, this article presents findings on workers' coverage under employer-sponsored retirement plans in 1993, and recent trends in coverage. The analysis focuses on workers 25-54, a group that includes the baby boom generation. Among all wage and salary workers in this age range (including government employees and part-time workers), 55 percent reported participating in a retirement plan on their current primary jobs, and an additional 3 percent were covered from other jobs. After a modest decline in the early 1980's, the coverage rate has remained essentially unchanged over the past 10 years, and limited data suggest that the baby boomers are doing about as well on pension coverage as older workers at similar points in their careers. Beneath this relative stability in overall coverage, however, at least two important changes have occurred: a significant narrowing of the gender gap in coverage and a shift in types of retirement plans. Increasing numbers of workers are being covered solely by 401(k)-type plans, a development that raises new uncertainties about the form and amount of future benefits. On the other hand, limited data in this study suggest that 401(k) plans may be serving their intended purpose for the majority of workers who have them.

  2. Radiation detectors laboratory; Laboratorio de detectores de radiacion

    Energy Technology Data Exchange (ETDEWEB)

    Ramirez J, F.J. [Instituto Nacional de Investigaciones Nucleares, A.P. 18-1027, 11801 Mexico D.F. (Mexico)

    1997-07-01

    The Radiation detectors laboratory was established with the assistance of the International Atomic Energy Agency which gave this the responsibility to provide its services at National and regional level for Latin America and it is located at the ININ. The more expensive and delicate radiation detectors are those made of semiconductor, so it has been put emphasis in the use and repairing of these detectors type. The supplied services by this laboratory are: selection consultant, detectors installation and handling and associated systems. Installation training, preventive and corrective maintenance of detectors and detection systems calibration. (Author)

  3. High performance visual display for HENP detectors

    International Nuclear Information System (INIS)

    McGuigan, Michael; Smith, Gordon; Spiletic, John; Fine, Valeri; Nevski, Pavel

    2001-01-01

    A high end visual display for High Energy Nuclear Physics (HENP) detectors is necessary because of the sheer size and complexity of the detector. For BNL this display will be of special interest because of STAR and ATLAS. To load, rotate, query, and debug simulation code with a modern detector simply takes too long even on a powerful work station. To visualize the HENP detectors with maximal performance we have developed software with the following characteristics. We develop a visual display of HENP detectors on BNL multiprocessor visualization server at multiple level of detail. We work with general and generic detector framework consistent with ROOT, GAUDI etc, to avoid conflicting with the many graphic development groups associated with specific detectors like STAR and ATLAS. We develop advanced OpenGL features such as transparency and polarized stereoscopy. We enable collaborative viewing of detector and events by directly running the analysis in BNL stereoscopic theatre. We construct enhanced interactive control, including the ability to slice, search and mark areas of the detector. We incorporate the ability to make a high quality still image of a view of the detector and the ability to generate animations and a fly through of the detector and output these to MPEG or VRML models. We develop data compression hardware and software so that remote interactive visualization will be possible among dispersed collaborators. We obtain real time visual display for events accumulated during simulations

  4. Obstacle detectors for automated transit vehicles: A technoeconomic and market analysis

    Science.gov (United States)

    Lockerby, C. E.

    1979-01-01

    A search was conducted to identify the technical and economic characteristics of both NASA and nonNASA obstacle detectors. The findings, along with market information were compiled and analyzed for consideration by DOT and NASA in decisions about any future automated transit vehicle obstacle detector research, development, or applications project. Currently available obstacle detectors and systems under development are identified by type (sonic, capacitance, infrared/optical, guided radar, and probe contact) and compared with the three NASA devices selected as possible improvements or solutions to the problems in existing obstacle detection systems. Cost analyses and market forecasts individually for the AGT and AMTV markets are included.

  5. Low level radioactivity measurements with phoswich detectors using coincident techniques and digital pulse processing analysis.

    Science.gov (United States)

    de la Fuente, R; de Celis, B; del Canto, V; Lumbreras, J M; de Celis Alonso, B; Martín-Martín, A; Gutierrez-Villanueva, J L

    2008-10-01

    A new system has been developed for the detection of low radioactivity levels of fission products and actinides using coincidence techniques. The device combines a phoswich detector for alpha/beta/gamma-ray recognition with a fast digital card for electronic pulse analysis. The phoswich can be used in a coincident mode by identifying the composed signal produced by the simultaneous detection of alpha/beta particles and X-rays/gamma particles. The technique of coincidences with phoswich detectors was proposed recently to verify the Nuclear Test Ban Treaty (NTBT) which established the necessity of monitoring low levels of gaseous fission products produced by underground nuclear explosions. With the device proposed here it is possible to identify the coincidence events and determine the energy and type of coincident particles. The sensitivity of the system has been improved by employing liquid scintillators and a high resolution low energy germanium detector. In this case it is possible to identify simultaneously by alpha/gamma coincidence transuranic nuclides present in environmental samples without necessity of performing radiochemical separation. The minimum detectable activity was estimated to be 0.01 Bq kg(-1) for 0.1 kg of soil and 1000 min counting.

  6. Low level radioactivity measurements with phoswich detectors using coincident techniques and digital pulse processing analysis

    International Nuclear Information System (INIS)

    Fuente, R. de la; Celis, B. de; Canto, V. del; Lumbreras, J.M.; Celis, Alonso B. de; Martin-Martin, A.; Gutierrez-Villanueva, J.L.

    2008-01-01

    A new system has been developed for the detection of low radioactivity levels of fission products and actinides using coincidence techniques. The device combines a phoswich detector for α/β/γ-ray recognition with a fast digital card for electronic pulse analysis. The phoswich can be used in a coincident mode by identifying the composed signal produced by the simultaneous detection of α/β particles and X-rays/γ particles. The technique of coincidences with phoswich detectors was proposed recently to verify the Nuclear Test Ban Treaty (NTBT) which established the necessity of monitoring low levels of gaseous fission products produced by underground nuclear explosions. With the device proposed here it is possible to identify the coincidence events and determine the energy and type of coincident particles. The sensitivity of the system has been improved by employing liquid scintillators and a high resolution low energy germanium detector. In this case it is possible to identify simultaneously by α/γ coincidence transuranic nuclides present in environmental samples without necessity of performing radiochemical separation. The minimum detectable activity was estimated to be 0.01 Bq kg -1 for 0.1 kg of soil and 1000 min counting

  7. 7 CFR 457.172 - Coverage Enhancement Option.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 6 2010-01-01 2010-01-01 false Coverage Enhancement Option. 457.172 Section 457.172..., DEPARTMENT OF AGRICULTURE COMMON CROP INSURANCE REGULATIONS § 457.172 Coverage Enhancement Option. The Coverage Enhancement Option for the 2009 and succeeding crop years are as follows: FCIC policies: United...

  8. 29 CFR 2.12 - Audiovisual coverage permitted.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 1 2010-07-01 2010-07-01 true Audiovisual coverage permitted. 2.12 Section 2.12 Labor Office of the Secretary of Labor GENERAL REGULATIONS Audiovisual Coverage of Administrative Hearings § 2.12 Audiovisual coverage permitted. The following are the types of hearings where the Department...

  9. Workplace Accommodations for Pregnant Employees: Associations With Women's Access to Health Insurance Coverage After Childbirth.

    Science.gov (United States)

    Jou, Judy; Kozhimannil, Katy B; Blewett, Lynn A; McGovern, Patricia M; Abraham, Jean M

    2016-06-01

    This study evaluates the associations between workplace accommodations for pregnancy, including paid and unpaid maternity leave, and changes in women's health insurance coverage postpartum. Secondary analysis using Listening to Mothers III, a national survey of women ages 18 to 45 years who gave birth in U.S. hospitals during 2011 to 2012 (N = 700). Compared with women without access to paid maternity leave, women with access to paid leave were 0.4 times as likely to lose private health insurance coverage, 0.3 times as likely to lose public health coverage, and 0.3 times as likely to become uninsured after giving birth. Workplace accommodations for pregnant employees are associated with health insurance coverage via work continuity postpartum. Expanding protections for employees during pregnancy and after childbirth may help reduce employee turnover, loss of health insurance coverage, and discontinuity of care.

  10. Detector and System Developments for LHC Detector Upgrades

    CERN Document Server

    Mandelli, Beatrice; Guida, Roberto; Rohne, Ole; Stapnes, Steinar

    2015-05-12

    The future Large Hadron Collider (LHC) Physics program and the consequent improvement of the LHC accelerator performance set important challenges to all detector systems. This PhD thesis delineates the studies and strategies adopted to improve two different types of detectors: the replacement of precision trackers with ever increasingly performing silicon detectors, and the improvement of large gaseous detector systems by optimizing their gas mixtures and operation modes. Within the LHC tracker upgrade programs, the ATLAS Insertable B-layer (IBL) is the first major upgrade of a silicon-pixel detector. Indeed the overall ATLAS Pixel Detector performance is expected to degrade with the increase of luminosity and the IBL will recover the performance by adding a fourth innermost layer. The IBL Detector makes use of new pixel and front-end electronics technologies as well as a novel thermal management approach and light support and service structures. These innovations required complex developments and Quality Ass...

  11. The effect of EDTA in attachment gain and root coverage.

    Science.gov (United States)

    Kassab, Moawia M; Cohen, Robert E; Andreana, Sebastiano; Dentino, Andrew R

    2006-06-01

    Root surface biomodification using low pH agents such as citric acid and tetracycline has been proposed to enhance root coverage following connective tissue grafting. The authors hypothesized that root conditioning with neutral pH edetic acid would improve vertical recession depth, root surface coverage, pocket depth, and clinical attachment levels. Twenty teeth in 10 patients with Miller class I and II recession were treated with connective tissue grafting. The experimental sites received 24% edetic acid in sterile distilled water applied to the root surface for 2 minutes before grafting. Controls were pretreated with only sterile distilled water. Measurements were evaluated before surgery and 6 months after surgery. Analysis of variance was used to determine differences between experimental and control groups. We found significant postoperative improvements in vertical recession depth, root surface coverage, and clinical attachment levels in test and control groups, compared to postoperative data. Pocket depth differences were not significant (P<.01).

  12. Functional coverages

    NARCIS (Netherlands)

    Donchyts, G.; Baart, F.; Jagers, H.R.A.; Van Dam, A.

    2011-01-01

    A new Application Programming Interface (API) is presented which simplifies working with geospatial coverages as well as many other data structures of a multi-dimensional nature. The main idea extends the Common Data Model (CDM) developed at the University Corporation for Atmospheric Research

  13. Detector Unit

    CERN Multimedia

    1960-01-01

    Original detector unit of the Instituut voor Kernfysisch Onderzoek (IKO) BOL project. This detector unit shows that silicon detectors for nuclear physics particle detection were already developed and in use in the 1960's in Amsterdam. Also the idea of putting 'strips' onto the silicon for high spatial resolution of a particle's impact on the detector were implemented in the BOL project which used 64 of these detector units. The IKO BOL project with its silicon particle detectors was designed, built and operated from 1965 to roughly 1977. Detector Unit of the BOL project: These detectors, notably the ‘checkerboard detector’, were developed during the years 1964-1968 in Amsterdam, The Netherlands, by the Natuurkundig Laboratorium of the N.V. Philips Gloeilampen Fabrieken. This was done in close collaboration with the Instituut voor Kernfysisch Onderzoek (IKO) where the read-out electronics for their use in the BOL Project was developed and produced.

  14. Effects of public premiums on children's health insurance coverage: evidence from 1999 to 2003.

    Science.gov (United States)

    Kenney, Genevieve; Hadley, Jack; Blavin, Fredric

    This study uses 2000 to 2004 Current Population Survey data to examine the effects of public premiums on the insurance coverage of children whose family incomes are between 100% and 300% of the federal poverty level. The analysis employs multinomial logistic models that control for factors other than premium costs. While the magnitude of the estimated effects varies across models, the results consistently indicate that raising public premiums reduces enrollment in public programs, with some children who forgo public coverage having private coverage instead and others being uninsured. The results indicate that public premiums have larger effects when applied to lower-income families.

  15. Calorimeter based detectors for high energy hadron colliders

    International Nuclear Information System (INIS)

    1993-01-01

    The work was directed in two complementary directions, the D0 experiment at Fermilab, and the GEM detector for the SSC. Efforts have been towards the data taking and analysis with the newly commissioned D0 detector at Fermilab in the bar pp Collider run that started in May 1992 and ended on June 1, 1993. We involved running and calibration of the calorimeter and tracking chambers, the second level trigger development, and various parts of the data analysis, as well as studies for the D0 upgrade planned in the second half of this decade. Another major accomplishment was the ''delivery'' of the Technical Design Report for the GEM SSC detector. Efforts to the overall detector and magnet design, design of the facilities, installation studies, muon system coordination, muon chamber design and tests, muon system simulation studies, and physics simulation studies. In this document we describe these activities separately

  16. 29 CFR 95.31 - Insurance coverage.

    Science.gov (United States)

    2010-07-01

    ... recipient. Federally-owned property need not be insured unless required by the terms and conditions of the... § 95.31 Insurance coverage. Recipients shall, at a minimum, provide the equivalent insurance coverage...

  17. Extending Coverage and Lifetime of K-coverage Wireless Sensor Networks Using Improved Harmony Search

    Directory of Open Access Journals (Sweden)

    Shohreh Ebrahimnezhad

    2011-07-01

    Full Text Available K-coverage wireless sensor networks try to provide facilities such that each hotspot region is covered by at least k sensors. Because, the fundamental evaluation metrics of such networks are coverage and lifetime, proposing an approach that extends both of them simultaneously has a lot of interests. In this article, it is supposed that two kinds of nodes are available: static and mobile. The proposed method, at first, tries to balance energy among sensor nodes using Improved Harmony Search (IHS algorithm in a k-coverage and connected wireless sensor network in order to achieve a sensor node deployment. Also, this method proposes a suitable place for a gateway node (Sink that collects data from all sensors. Second, in order to prolong the network lifetime, some of the high energy-consuming mobile nodes are moved to the closest positions of low energy-consuming ones and vice versa after a while. This leads increasing the lifetime of network while connectivity and k-coverage are preserved. Through computer simulations, experimental results verified that the proposed IHS-based algorithm found better solution compared to some related methods.

  18. Report of the detector laboratory

    International Nuclear Information System (INIS)

    Lynen, U.; Stelzer, H.; Fischer, B.

    1975-01-01

    Parallel plate detectors with sizes up to 30 x 30 cm 2 have been built and time resolutions of 350 psec for α-particles and approximately 200 psec for 25 MeV 16 O have been obtained. For these detectors a fast preamplifier was developed. Two digital processers for multiplication and division of 13-bit numbers have been built. For a PDP 11/40 a program has been developed which allows the on- and off-line data analysis. (orig.) [de

  19. Attaining higher coverage: obstacles to overcome. English-speaking Caribbean and Suriname.

    Science.gov (United States)

    1984-12-01

    In 1983, 8 (42%) of the 19 English-speaking Caribbean countries (including Suriname) achieved at least 50% coverage with 3 doses of diphtheria-pertussis-tetanus (DPT) vaccine among children under 1 year of age and 6 countries (32%) had at least 50% coverage with 3 doses of trivalent oral polio vaccine (TOPV). In addition, 10 countries (53%) achieved over 75% DPT coverage and 11 (58%) achieved over 75% TOPV coverage. Despite this record of progress, several factors continue to impede further gains in immunization coverage. Of particular concern is the high dropout rate. As many as 25% of infants receive their 1st dose of DPT and TOPV but do not return to complete their course of immunization. There is also a need for each health center to estimate its annual target population for immunization every year through analysis of the total live births from the previous year in the health center's catchment area (minus infant mortality). Monthly target figures can thus be computed and coverage monitored. A further problem has been a reluctance on the part of some health workers to administer vaccines simultaneously. This does not reduce effectiveness or increase the risk of complications, and reduces the number of visits needed to complete the immunization schedule. An unresolved question is whether to immunize ill or malnourished children. Decisions on this matter should take into account the availability and accessibility of health care services, the ability to follow-up children who are not immunized, and the likelihood that children will return for subsequent immunizations. Finally, a number of immunizations performed by private practitioners and institutions are not reported. Both public and private health care providers should agree on a standardized reporting format to allow better estimation of coverage.

  20. Analysis and optimal design of Si microstrip detector with overhanging metal electrode

    CERN Document Server

    Ranjan, Kirti; Chatterji, S; Srivastava-Ajay, K; Shivpuri, R K

    2001-01-01

    The harsh radiation environment to be encountered at LHC (large hadron collider) and RHIC (relativistic heavy ion collider) poses a challenging task for the fabrication of Si microstrip detectors. Due to high luminosities, detectors are required to sustain very high voltage operation well exceeding the bias voltage needed to fully deplete them. The "overhanging" metal contact is now a well established technique for improving the breakdown performance of the Si microstrip detector. Based on computer simulation, the influence of various physical and geometrical parameters on the electrical breakdown of the Si detectors equipped with metal overhangs is extensively analysed. Furthermore, optimization of design parameters is performed to achieve breakdown voltages close to maximum realizable values. The simulation results are found to be in good agreement with experimental data. (17 refs).

  1. Position sensitivity of the first SmartPET HPGe detector

    Energy Technology Data Exchange (ETDEWEB)

    Cooper, R.J. [Department of Physics, University of Liverpool, Liverpool (United Kingdom)]. E-mail: rjc@ns.ph.liv.ac.uk; Turk, G. [Department of Physics, University of Liverpool, Liverpool (United Kingdom); Boston, A.J. [Department of Physics, University of Liverpool, Liverpool (United Kingdom); Boston, H.C. [Department of Physics, University of Liverpool, Liverpool (United Kingdom); Cresswell, J.R. [Department of Physics, University of Liverpool, Liverpool (United Kingdom); Mather, A.R. [Department of Physics, University of Liverpool, Liverpool (United Kingdom); Nolan, P.J. [Department of Physics, University of Liverpool, Liverpool (United Kingdom); Hall, C.J. [CCLRC Daresbury, Warrington, Cheshire (United Kingdom); Lazarus, I. [CCLRC Daresbury, Warrington, Cheshire (United Kingdom); Simpson, J. [CCLRC Daresbury, Warrington, Cheshire (United Kingdom); Berry, A. [School of Physics and materials Engineering, Monash University, Melbourne (Australia); Beveridge, T. [School of Physics and materials Engineering, Monash University, Melbourne (Australia); Gillam, J. [School of Physics and materials Engineering, Monash University, Melbourne (Australia); Lewis, R.A. [School of Physics and materials Engineering, Monash University, Melbourne (Australia)

    2007-04-01

    In this paper we discuss the Smart Positron Emission Tomography (PET) imaging system being developed by University of Liverpool in conjunction with CCLRC Daresbury Laboratory. We describe the motivation for the development of a semiconductor-based PET system and the advantages it will offer over current tomographs. Details of the detectors and associated electronics are discussed and results of high precision scans are presented. Analysis of this scan data has facilitated full characterization of the detector response function and calibration of the three-dimensional position sensitivity. This work presents the analysis of the depth sensitivity of the detector.

  2. Timing of gamma rays in coaxial germanium detector systems

    International Nuclear Information System (INIS)

    El-Ibiary, M.Y.

    1979-01-01

    A study is reported on the timing uncertainty in gamma ray coaxial germanium detector systems. The work deals with the zero cross over method which is widely used to reduce the dependence of the instant of timing on the radiation energy absorbed and on the position within the detector at which absorption takes place. It is found that the amplitude risetime compensated (ARC) method gives, under normal conditions, the best resolution at a specific energy. For higher energies, the resolution improves and there is no shift of the mean instant of timing. The method is therefore well suited for wide energy coverage. The parameters involved in implementing an ARC system for optimum performance at a specific energy are identified in terms of the preamplifier noise level and risetime. A trade off can be made between the resolutions at high and at low energies. The time resolution attained is given by means of a series of charts which use normalized dimensionless variables for ready application to any given case. Lithium compensated Ge detectors which normally operate under conditions of velocity saturation of the charge carriers by applying sufficient bias voltage create an electric field in excess of 1 kV/cm throughout the depleted region. High purity Ge detectors where velocity saturation may not be reached within certain parts of the depleted region are studied. Special attention is given to the probability of pulses being incorrectly timed because of their slow rise or small magnitude. Such incorrect timing is energy-dependent and results in a noticeable distortion of the timing spectrum that relates to a wide energy range. Limitations on system parameters to keep the probability of incorrect timing below a specified fraction are given

  3. The TOTEM detector at LHC

    Science.gov (United States)

    Antchev, G.; Aspell, P.; Atanassov, I.; Avati, V.; Berardi, V.; Berretti, M.; Bozzo, M.; Brucken, E.; Buzzo, A.; Cafagna, F.; Calicchio, M.; Catanesi, M. G.; Ciocci, M. A.; Csanád, M.; Csörgő, T.; Deile, M.; Dénes, E.; Dimovasili, E.; Doubek, M.; Eggert, K.; Ferro, F.; Garcia, F.; Giani, S.; Greco, V.; Grzanka, L.; Heino, J.; Hilden, T.; Janda, M.; Kaˇspar, J.; Kopal, J.; Kundrat, V.; Kurvinen, K.; Lami, S.; Latino, G.; Lauhakangas, R.; Lippmaa, E.; Lokajicek, M.; Lo Vetere, M.; Lucas Rodriguez, F.; Macri`, M.; Magazzu`, G.; Minutoli, S.; Niewiadomski, H.; Notarnicola, G.; Novak, T.; Oliveri, E.; Oljemark, F.; Orava, R.; Oriunno, M.; Osterberg, K.; Palazzi, P.; Pedreschi, E.; Petajajarvi, J.; Quinto, M.; Radermacher, E.; Radicioni, E.; Ravotti, F.; Robutti, E.; Ropelewski, L.; Ruggiero, G.; Rummel, A.; Saarikko, H.; Sanguinetti, G.; Santroni, A.; Scribano, A.; Sette, G.; Snoeys, W.; Spearman, W.; Spinella, F.; Ster, A.; Taylor, C.; Trummal, A.; Turini, N.; Vacek, V.; Vitek, M.; Whitmore, J.; Wu, J.

    2010-05-01

    The TOTEM experiment, small in size compared to the others at the LHC, is dedicated to the measurement of the total proton-proton cross-sections with a luminosity-independent method and to the study of elastic and diffractive scattering at the LHC. To achieve optimum forward coverage for charged particles emitted by the pp collisions in the IP5 interaction point, two tracking telescopes, T1 and T2, will be installed on each side in the pseudo-rapidity region between 3.1 and 6.5, and Roman Pot stations will be placed at distances of 147 and 220 m from IP5. The telescope closest to the interaction point (T1, centred at z=9 m) consists of Cathode Strip Chambers (CSC), while the second one (T2, centred at 13.5 m), makes use of Gas Electron Multipliers (GEM). The proton detectors in the Roman Pots are silicon devices designed by TOTEM with the specific objective of reducing down to a few tens of microns the insensitive area at the edge. High efficiency as close as possible to the physical detector boundary is an essential feature. It maximizes the experimental acceptance for protons scattered elastically or interactively at polar angles down to a few micro-radians at IP5. To measure protons at the lowest possible emission angles, special beam optics have been conceived to optimize proton detection in terms of acceptance and resolution. The read-out of all TOTEM subsystems is based on the custom-developed digital VFAT chip with trigger capability.

  4. The TOTEM detector at LHC

    International Nuclear Information System (INIS)

    Antchev, G.; Aspell, P.; Atanassov, I.; Avati, V.; Berardi, V.; Berretti, M.; Bozzo, M.; Brucken, E.; Buzzo, A.; Cafagna, F.; Calicchio, M.; Catanesi, M.G.; Ciocci, M.A.; Csanad, M.; Csoergo, T.; Deile, M.; Denes, E.; Dimovasili, E.; Doubek, M.; Eggert, K.

    2010-01-01

    The TOTEM experiment, small in size compared to the others at the LHC, is dedicated to the measurement of the total proton-proton cross-sections with a luminosity-independent method and to the study of elastic and diffractive scattering at the LHC. To achieve optimum forward coverage for charged particles emitted by the pp collisions in the IP5 interaction point, two tracking telescopes, T1 and T2, will be installed on each side in the pseudo-rapidity region between 3.1 and 6.5, and Roman Pot stations will be placed at distances of 147 and 220 m from IP5. The telescope closest to the interaction point (T1, centred at z=9 m) consists of Cathode Strip Chambers (CSC), while the second one (T2, centred at 13.5 m), makes use of Gas Electron Multipliers (GEM). The proton detectors in the Roman Pots are silicon devices designed by TOTEM with the specific objective of reducing down to a few tens of microns the insensitive area at the edge. High efficiency as close as possible to the physical detector boundary is an essential feature. It maximizes the experimental acceptance for protons scattered elastically or interactively at polar angles down to a few micro-radians at IP5. To measure protons at the lowest possible emission angles, special beam optics have been conceived to optimize proton detection in terms of acceptance and resolution. The read-out of all TOTEM subsystems is based on the custom-developed digital VFAT chip with trigger capability.

  5. The TOTEM detector at LHC

    Energy Technology Data Exchange (ETDEWEB)

    Antchev, G.; Aspell, P.; Atanassov, I. [CERN, CH-1211 Geneva 23 (Switzerland); Avati, V. [CERN, CH-1211 Geneva 23 (Switzerland); Penn State University, Dept. of Physics, University Park, PA (United States); Berardi, V. [INFN Sezione di Bari and Politecnico di Bari, Bari (Italy); Berretti, M. [INFN Sezione di Pisa and Universita di Siena (Italy); Bozzo, M. [Universita di Genova and Sezione INFN, Genova (Italy); Brucken, E. [Helsinki Institute of Physics and Department of Physics, University of Helsinki (Finland); Buzzo, A. [Universita di Genova and Sezione INFN, Genova (Italy); Cafagna, F.; Calicchio, M.; Catanesi, M.G. [INFN Sezione di Bari and Politecnico di Bari, Bari (Italy); Ciocci, M.A. [INFN Sezione di Pisa and Universita di Siena (Italy); Csanad, M.; Csoergo, T. [MTA KFKI RMKI, Budapest (Hungary); Deile, M. [CERN, CH-1211 Geneva 23 (Switzerland); Denes, E. [MTA KFKI RMKI, Budapest (Hungary); Dimovasili, E. [CERN, CH-1211 Geneva 23 (Switzerland); Penn State University, Dept. of Physics, University Park, PA (United States); Doubek, M.; Eggert, K. [Penn State University, Dept. of Physics, University Park, PA (United States)

    2010-05-21

    The TOTEM experiment, small in size compared to the others at the LHC, is dedicated to the measurement of the total proton-proton cross-sections with a luminosity-independent method and to the study of elastic and diffractive scattering at the LHC. To achieve optimum forward coverage for charged particles emitted by the pp collisions in the IP5 interaction point, two tracking telescopes, T1 and T2, will be installed on each side in the pseudo-rapidity region between 3.1 and 6.5, and Roman Pot stations will be placed at distances of 147 and 220 m from IP5. The telescope closest to the interaction point (T1, centred at z=9 m) consists of Cathode Strip Chambers (CSC), while the second one (T2, centred at 13.5 m), makes use of Gas Electron Multipliers (GEM). The proton detectors in the Roman Pots are silicon devices designed by TOTEM with the specific objective of reducing down to a few tens of microns the insensitive area at the edge. High efficiency as close as possible to the physical detector boundary is an essential feature. It maximizes the experimental acceptance for protons scattered elastically or interactively at polar angles down to a few micro-radians at IP5. To measure protons at the lowest possible emission angles, special beam optics have been conceived to optimize proton detection in terms of acceptance and resolution. The read-out of all TOTEM subsystems is based on the custom-developed digital VFAT chip with trigger capability.

  6. Construction of a self-powered neutron detector prototype

    International Nuclear Information System (INIS)

    Pombo, J.B.S.M.; Correa, R.F.

    1986-01-01

    Description and testing of a self-powered neutron detector and related current measurement electronics, in construction at Centro de Desenvolviemnto da Tecnologia Nuclear (CDTN), are presented. The cylindrical detector has a 9-wires cobalt emitter, Inconel 600 tubing collector and sinterized alumina electrical insulation. The bifilar signal cable is plugged to the detector through a SHV connector. Preliminary testing has giving information about dielectrical properties of the set and impurities of the materials (by means of activation analysis). The main tests, done in a 100 KW Triga Reactor, allowed the verification of the detector response to the neutron flux, the stability and reproducibility of this response, and also the evaluation of sensitivity to gamma radiation. The detector performance is considered good. (Author) [pt

  7. Dental Care Coverage and Use: Modeling Limitations and Opportunities

    Science.gov (United States)

    Moeller, John F.; Chen, Haiyan

    2014-01-01

    Objectives. We examined why older US adults without dental care coverage and use would have lower use rates if offered coverage than do those who currently have coverage. Methods. We used data from the 2008 Health and Retirement Study to estimate a multinomial logistic model to analyze the influence of personal characteristics in the grouping of older US adults into those with and those without dental care coverage and dental care use. Results. Compared with persons with no coverage and no dental care use, users of dental care with coverage were more likely to be younger, female, wealthier, college graduates, married, in excellent or very good health, and not missing all their permanent teeth. Conclusions. Providing dental care coverage to uninsured older US adults without use will not necessarily result in use rates similar to those with prior coverage and use. We have offered a model using modifiable factors that may help policy planners facilitate programs to increase dental care coverage uptake and use. PMID:24328635

  8. Performance of the Totem Detectors at the LHC

    CERN Document Server

    INSPIRE-00062364; Aspell, P.; Atanassov, I.; Avati, V.; Baechler, J.; Bagliesi, M.G.; Berardi, V.; Berretti, M.; Bossini, E.; Bottigli, U.; Bozzo, M.; Brücken, E.; Buzzo, A.; Cafagna, F.S.; Catanesi, M.G.; Cecchi, R.; Covault, C.; Csanád, M.; Csörgő, T.; Deile, M.; Doubek, M.; Eggert, K.; Eremin, V.; Ferro, F.; Fiergolski, A.; Garcia, F.; Giani, S.; Greco, V.; Grzanka, L.; Heino, J.; Hilden, T.; Karev, A.; Kašpar, J.; Kopal, J.; Kundrát, V.; Lami, S.; Latino, G.; Lauhakangas, R.; Leszko, T.; Lippmaa, E.; Lippmaa, J.; Lokajíček, M.; Losurdo, L.; Lo Vetere, M.; Lucas Rodríguez, F.; Macrí, M.; Mäki, T.; Mercadante, A.; Minafra, N.; Minutoli, S.; Nemes, F.; Niewiadomski, H.; Oliveri, E.; Oljemark, F.; Orava, R.; Oriunno, M.; Österberg, K.; Palazzi, P.; Pedreschi, E.; Procházka, J.; Quinto, M.; Radermacher, E.; Radicioni, E.; Ravotti, F.; Robutti, E.; Ropelewski, L.; Ruggiero, G.; Saarikko, H.; Scribano, A.; Smajek, J.; Snoeys, W.; Spinella, F.; Sziklai, J.; Taylor, C.; Thys, A.; Turini, N.; Vacek, V.; Vítek, M.; Welti, J.; Whitmore, J.; Wyszkowski, P.

    2013-01-01

    The TOTEM Experiment is designed to measure the total proton-proton cross-section with the luminosity-independent method and to study elastic and diffractive pp scattering at the LHC. To achieve optimum forward coverage for charged particles emitted by the pp collisions in the interaction point IP5, two tracking telescopes, T1 and T2, are installed on each side of the IP in the pseudorapidity region 3.1 $\\le |\\eta| \\le $6.5, and special movable beam-pipe insertions – called Roman Pots (RP) – are placed at distances of ±147m and ±220m from IP5. This article describes in detail the working of the TOTEM detector to produce physics results in the first three years of operation and data taking at the LHC.

  9. Analysis of long-lived particle decays with the MATHUSLA detector

    Science.gov (United States)

    Curtin, David; Peskin, Michael E.

    2018-01-01

    The MATHUSLA detector is a simple large-volume tracking detector to be located on the surface above one of the general-purpose experiments at the Large Hadron Collider. This detector was proposed in [J. P. Chou, D. Curtin, and H. J. Lubatti, Phys. Lett. B 767, 29 (2017), 10.1016/j.physletb.2017.01.043] to detect exotic, neutral, long-lived particles that might be produced in high-energy proton-proton collisions. In this paper, we consider the use of the limited information that MATHULSA would provide on the decay products of the long-lived particle. For the case in which the long-lived particle is pair-produced in Higgs boson decays, we show that it is possible to measure the mass of this particle and determine the dominant decay mode with less than 100 observed events. We discuss the ability of MATHUSLA to distinguish the production mode of the long-lived particle and to determine its mass and spin in more general cases.

  10. A comprehensive analysis of irradiated silicon detectors at cryogenic temperatures

    CERN Document Server

    Santocchia, A; Hall, G; MacEvoy, B; Moscatelli, F; Passeri, D; Pignatel, Giogrio Umberto

    2003-01-01

    The effect of particle irradiation on high-resistivity silicon detectors has been extensively studied with the goal of engineering devices able to survive the very challenging radiation environment at the CERN Large Hadron Collider (LHC). The main aspect under investigation has been the changes observed in detector effective doping concentration (N/sub eff/). We have previously proposed a mechanism to explain the evolution of N/sub eff/, whereby charge is exchanged directly between closely-spaced defect centres in the dense terminal clusters formed by hadron irradiation. This model has been implemented in both a commercial finite-element device simulator (ISE-TCAD) and a purpose-built simulation of interdefect charge exchange. To control the risk of breakdown due to the high leakage currents foreseen during ten years of LHC operation, silicon detectors will be operated below room temperature (around -10 degrees C). This, and more general current interest in the field of cryogenic operation, has led us to inve...

  11. A coverage and slicing dependencies analysis for seeking software security defects.

    Science.gov (United States)

    He, Hui; Zhang, Dongyan; Liu, Min; Zhang, Weizhe; Gao, Dongmin

    2014-01-01

    Software security defects have a serious impact on the software quality and reliability. It is a major hidden danger for the operation of a system that a software system has some security flaws. When the scale of the software increases, its vulnerability has becoming much more difficult to find out. Once these vulnerabilities are exploited, it may lead to great loss. In this situation, the concept of Software Assurance is carried out by some experts. And the automated fault localization technique is a part of the research of Software Assurance. Currently, automated fault localization method includes coverage based fault localization (CBFL) and program slicing. Both of the methods have their own location advantages and defects. In this paper, we have put forward a new method, named Reverse Data Dependence Analysis Model, which integrates the two methods by analyzing the program structure. On this basis, we finally proposed a new automated fault localization method. This method not only is automation lossless but also changes the basic location unit into single sentence, which makes the location effect more accurate. Through several experiments, we proved that our method is more effective. Furthermore, we analyzed the effectiveness among these existing methods and different faults.

  12. Investigations of the response of hybrid particle detectors for the Space Environmental Viewing and Analysis Network (SEVAN

    Directory of Open Access Journals (Sweden)

    A. Chilingarian

    2008-02-01

    Full Text Available A network of particle detectors located at middle to low latitudes known as SEVAN (Space Environmental Viewing and Analysis Network is being created in the framework of the International Heliophysical Year (IHY-2007. It aims to improve the fundamental research of the particle acceleration in the vicinity of the Sun and space environment conditions. The new type of particle detectors will simultaneously measure the changing fluxes of most species of secondary cosmic rays, thus turning into a powerful integrated device used for exploration of solar modulation effects. Ground-based detectors measure time series of secondary particles born in cascades originating in the atmosphere by nuclear interactions of protons and nuclei accelerated in the galaxy. During violent solar explosions, sometimes additional secondary particles are added to this "background" flux. The studies of the changing time series of secondary particles shed light on the high-energy particle acceleration mechanisms. The time series of intensities of high energy particles can also provide highly cost-effective information on the key characteristics of interplanetary disturbances. The recent results of the detection of the solar extreme events (2003–2005 by the monitors of the Aragats Space-Environmental Center (ASEC illustrate the wide possibilities provided by new particle detectors measuring neutron, electron and muon fluxes with inherent correlations. We present the results of the simulation studies revealing the characteristics of the SEVAN networks' basic measuring module. We illustrate the possibilities of the hybrid particle detector to measure neutral and charged fluxes of secondary CR, to estimate the efficiency and purity of detection; corresponding median energies of the primary proton flux, the ability to distinguish between neutron and proton initiated GLEs and some other important properties of hybrid particle detectors.

  13. Similar challenges but different responses: Media coverage of measles vaccination in the UK and China.

    Science.gov (United States)

    Ren, Jie; Peters, Hans Peter; Allgaier, Joachim; Lo, Yin-Yueh

    2014-05-01

    For several decades scholars have studied media reporting on scientific issues that involve controversy. Most studies so far have focused on the western world. This article tries to broaden the perspective by considering China and comparing it to a western country. A content analysis of newspaper coverage of vaccination issues in the UK and China shows, first, that the government-supported 'mainstream position' dominates the Chinese coverage while the British media frequently refer to criticism and controversy. Second, scientific expertise in the British coverage is represented by experts from the health and science sector but by experts from health agencies in the Chinese coverage. These results are discussed with respect to implications for risk communication and scientists' involvement in public communication.

  14. Gravitational-wave physics and astronomy an introduction to theory, experiment and data analysis

    CERN Document Server

    Creighton, Jolien D E

    2011-01-01

    This most up-to-date, one-stop reference combines coverage of both theory and observational techniques, with introductory sections to bring all readers up to the same level. Written by outstanding researchers directly involved with the scientific program of the Laser Interferometer Gravitational-Wave Observatory (LIGO), the book begins with a brief review of general relativity before going on to describe the physics of gravitational waves and the astrophysical sources of gravitational radiation. Further sections cover gravitational wave detectors, data analysis, and the outlook of gravitation

  15. CHICSi - a compact ultra-high vacuum compatible detector system for nuclear reaction experiments at storage rings. I. General structure, mechanics and UHV compatibility

    International Nuclear Information System (INIS)

    Westerberg, L.; Avdeichikov, V.; Carlen, L.; Golubev, P.; Jakobsson, B.; Rouki, C.; Siwek, A.; Veldhuizen, E.J. van; Whitlow, H.J.

    2003-01-01

    CELSIUS Heavy-Ion Collision Silicon detector system (CHICSi) is a large solid angle, barrel-shaped detector system, housing up to 600 detector telescopes arranged in rotational symmetry around the beam axis. CHICSi measures charged particles and fragments from nuclear reactions. It operates at internal targets of storage rings. In order to optimize space and momentum-space coverage and minimize the low-energy detection limits, CHICSi is designed for use in ultra-high vacuum (UHV, ∼10 -8 Pa) inside a cluster-jet target chamber. This calls for materials in mechanical support, detectors, Very Large Scale Integrated (VLSI) electronics, connectors, cables and other signal transport devices with very low outgassing. Two auxiliary detector systems, which will operate in coincidence with CHICSi, a heavy-recoil, time-of-flight system (HR-TOF) also placed inside the target chamber and a projectile fragmentation wall (PF-WALL) located outside the chamber, have also been constructed. In total, this combined system registers more than 80% of all charged particles and fragments from typical heavy-ion reactions at energies of a few hundreds of MeV per nucleon

  16. CHICSi - a compact ultra-high vacuum compatible detector system for nuclear reaction experiments at storage rings. I. General structure, mechanics and UHV compatibility

    Energy Technology Data Exchange (ETDEWEB)

    Westerberg, L.; Avdeichikov, V.; Carlen, L.; Golubev, P.; Jakobsson, B. E-mail: bo.jakobsson@kosufy.lu.se; Rouki, C.; Siwek, A.; Veldhuizen, E.J. van; Whitlow, H.J

    2003-03-11

    CELSIUS Heavy-Ion Collision Silicon detector system (CHICSi) is a large solid angle, barrel-shaped detector system, housing up to 600 detector telescopes arranged in rotational symmetry around the beam axis. CHICSi measures charged particles and fragments from nuclear reactions. It operates at internal targets of storage rings. In order to optimize space and momentum-space coverage and minimize the low-energy detection limits, CHICSi is designed for use in ultra-high vacuum (UHV, {approx}10{sup -8} Pa) inside a cluster-jet target chamber. This calls for materials in mechanical support, detectors, Very Large Scale Integrated (VLSI) electronics, connectors, cables and other signal transport devices with very low outgassing. Two auxiliary detector systems, which will operate in coincidence with CHICSi, a heavy-recoil, time-of-flight system (HR-TOF) also placed inside the target chamber and a projectile fragmentation wall (PF-WALL) located outside the chamber, have also been constructed. In total, this combined system registers more than 80% of all charged particles and fragments from typical heavy-ion reactions at energies of a few hundreds of MeV per nucleon.

  17. Development and analysis of silicon based detectors for low energy nuclear radiation

    International Nuclear Information System (INIS)

    Johansen, G.A.

    1990-11-01

    The design and assembly of a prototype silicon based detector especially for the detection of auroral X-rays is presented. The theoretical fundamentals are shown and the adoption of the detector for applications in future satellite experiments are described. 136 refs

  18. Design and optimization of electrochemical detectors for HPLC and flow analysis systems

    NARCIS (Netherlands)

    Brunt, Kommer

    1980-01-01

    In dit proefschrift worden twee nieuwe electrochemische detectoren beschreven. De differentiële amperometrische detector is speciaal ontworpen voor de hoge druk vloeistof chromatografie, terwijl de amperometrische detector die berust op het principe van een roterende " wall - jet " electrode ook

  19. Systematic Review and Comparative Meta-Analysis of Outcomes Following Pedicled Muscle versus Fasciocutaneous Flap Coverage for Complex Periprosthetic Wounds in Patients with Total Knee Arthroplasty

    Directory of Open Access Journals (Sweden)

    James M. Economides

    2017-03-01

    Full Text Available BackgroundIn cases of total knee arthroplasty (TKA threatened by potential hardware exposure, flap-based reconstruction is indicated to provide durable coverage. Historically, muscle flaps were favored as they provide vascular tissue to an infected wound bed. However, data comparing the performance of muscle versus fasciocutaneous flaps are limited and reflect a lack of consensus regarding the optimal management of these wounds. The aim of this study was to compare the outcomes of muscle versus fasciocutaneous flaps following the salvage of compromised TKA.MethodsA systematic search and meta-analysis were performed to identify patients with TKA who underwent either pedicled muscle or fasciocutaneous flap coverage of periprosthetic knee defects. Studies evaluating implant/limb salvage rates, ambulatory function, complications, and donor-site morbidity were included in the comparative analysis.ResultsA total of 18 articles, corresponding to 172 flaps (119 muscle flaps and 53 fasciocutaneous flaps were reviewed. Rates of implant salvage (88.8% vs. 90.1%, P=0.05 and limb salvage (89.8% vs. 100%, P=0.14 were comparable in each cohort. While overall complication rates were similar (47.3% vs. 44%, P=0.78, the rates of persistent infection (16.4% vs. 0%, P=0.14 and recurrent infection (9.1% vs. 4%, P=0.94 tended to be higher in the muscle flap cohort. Notably, functional outcomes and ambulation rates were sparingly reported.ConclusionsRates of limb and prosthetic salvage were comparable following muscle or fasciocutaneous flap coverage of compromised TKA. The functional morbidity associated with muscle flap harvest, however, may support the use of fasciocutaneous flaps for coverage of these defects, particularly in young patients and/or high-performance athletes.

  20. Preliminary results of fission induced by (1068 MeV) pi in Cu, Sn, Au and Bi using CR-39 detectors

    CERN Document Server

    Khan, H A; Shahzad, M I; Manzoor, S; Farooq, M A; Sher, G; Khan, E U; Peterson, R J

    1999-01-01

    Fission probabilities in pion induced reactions exhibit characteristic variations with respect to pion energies and target fissility values. At incident energies well above the pion-nucleon resonances, the statistical model seems to give good description of the observed data. We have used negative pions of energy 1068 MeV, in order to study fission induced in four target materials with fissility values [(Z-1)2/A] ranging from 12 to 32. All targets were arranged in a single stack in such a way that each target coated on a CR-39 detector was sandwiched by another uncoated CR-39 detector plate. The stack was irradiated at the AGS of Brookhaven National Laboratory (USA). This set-up ensures solid angle coverage of almost 4 pi degrees, so that for each fission event one of the fission fragments is expected to be trapped by the forward detector and one by the detector covering backward hemisphere. The effect of pion momentum transfer to the struck nucleus was observed in the form of asymmetry between events counted...

  1. Towards Semantic Web Services on Large, Multi-Dimensional Coverages

    Science.gov (United States)

    Baumann, P.

    2009-04-01

    Observed and simulated data in the Earth Sciences often come as coverages, the general term for space-time varying phenomena as set forth by standardization bodies like the Open GeoSpatial Consortium (OGC) and ISO. Among such data are 1-d time series, 2-D surface data, 3-D surface data time series as well as x/y/z geophysical and oceanographic data, and 4-D metocean simulation results. With increasing dimensionality the data sizes grow exponentially, up to Petabyte object sizes. Open standards for exploiting coverage archives over the Web are available to a varying extent. The OGC Web Coverage Service (WCS) standard defines basic extraction operations: spatio-temporal and band subsetting, scaling, reprojection, and data format encoding of the result - a simple interoperable interface for coverage access. More processing functionality is available with products like Matlab, Grid-type interfaces, and the OGC Web Processing Service (WPS). However, these often lack properties known as advantageous from databases: declarativeness (describe results rather than the algorithms), safe in evaluation (no request can keep a server busy infinitely), and optimizable (enable the server to rearrange the request so as to produce the same result faster). WPS defines a geo-enabled SOAP interface for remote procedure calls. This allows to webify any program, but does not allow for semantic interoperability: a function is identified only by its function name and parameters while the semantics is encoded in the (only human readable) title and abstract. Hence, another desirable property is missing, namely an explicit semantics which allows for machine-machine communication and reasoning a la Semantic Web. The OGC Web Coverage Processing Service (WCPS) language, which has been adopted as an international standard by OGC in December 2008, defines a flexible interface for the navigation, extraction, and ad-hoc analysis of large, multi-dimensional raster coverages. It is abstract in that it

  2. The environment in the headlines. Newspaper coverage of climate change and euthropication in Finland

    Energy Technology Data Exchange (ETDEWEB)

    Lyytimaeki, J.

    2009-07-01

    Media representations are an important part of the dynamics of contemporary socio-ecological systems. The media agenda influences and interacts with the public and the policy agenda and all of these are connected to the changes of the state of the environment. Partly as a result of media debate, some issues are considered serious environmental problems, some risks are amplified while others are attenuated, and some proposals for remedies are highlighted and others downplayed. Research on environmental media coverage has focused predominantly on the English-speaking industrialised countries. This thesis presents an analysis of Finnish environmental coverage, focusing on representations of climate change and eutrophication from 1990- 2010. The main source of material is Helsingin Sanomat (HS), the most widely-read newspaper in Finland. The analysis adopts the perspective of contextual constructivism and the agenda-setting function of the mass media. Selected models describing the evolution of environmental coverage are applied within an interdisciplinary emphasis. The results show that the amount of newspaper content on eutrophication and climate change has generally increased, although both debates have been characterised by intense fluctuations. The volume of the coverage on climate change has been higher than that of eutrophication, especially since 2006. Eutrophication was highlighted most during the late 1990s while the peaks of climate coverage occurred between 2007 and 2009. Two key factors have shaped the coverage of eutrophication. First, the coverage is shaped by ecological factors, especially by the algal occurrences that are largely dependent on weather conditions. Second, the national algal monitoring and communication system run by environmental authorities has provided the media with easy-to-use data on the algal situation during the summertime. The peaks of climate coverage have been caused by an accumulation of several contributing factors. The two

  3. Impact of state Medicaid coverage on utilization of inpatient rehabilitation facilities among patients with stroke.

    Science.gov (United States)

    Skolarus, Lesli E; Burke, James F; Morgenstern, Lewis B; Meurer, William J; Adelman, Eric E; Kerber, Kevin A; Callaghan, Brian C; Lisabeth, Lynda D

    2014-08-01

    Poststroke rehabilitation is associated with improved outcomes. Medicaid coverage of inpatient rehabilitation facility (IRF) admissions varies by state. We explored the role of state Medicaid IRF coverage on IRF utilization among patients with stroke. Working age ischemic stroke patients with Medicaid were identified from the 2010 Nationwide Inpatient Sample. Medicaid coverage of IRFs (yes versus no) was ascertained. Primary outcome was discharge to IRF (versus other discharge destinations). We fit a logistic regression model that included patient demographics, Medicaid coverage, comorbidities, length of stay, tissue-type plasminogen activator use, state Medicaid IRF coverage, and the interaction between patient Medicaid status and state Medicaid IRF coverage while accounting for hospital clustering. Medicaid did not cover IRFs in 4 (TN, TX, SC, WV) of 42 states. The impact of State Medicaid IRF coverage was limited to Medicaid stroke patients (P for interaction stroke patients in states with Medicaid IRF coverage, Medicaid stroke patients hospitalized in states without Medicaid IRF coverage were less likely to be discharged to an IRF of 11.6% (95% confidence interval, 8.5%-14.7%) versus 19.5% (95% confidence interval, 18.3%-20.8%), Pstroke patients with Medicaid. Given the increasing stroke incidence among the working age and Medicaid expansion under the Affordable Care Act, careful attention to state Medicaid policy for poststroke rehabilitation and analysis of its effects on stroke outcome disparities are warranted. © 2014 American Heart Association, Inc.

  4. JIGSAW: Acquisition, Display and Analysis system designed to collect data from Multiple Gamma-Ray detectors

    International Nuclear Information System (INIS)

    Haywood, S.E.; Bamford, G.J.; Rester, A.C.; Coldwell, R.L.

    1992-01-01

    In this paper, the authors report on work performed to date on JIGSAW - a self contained data acquisition, display and analysis system designed to collect data form multiple gamma-ray detectors. The data acquisition system utilizes commercially available VMEbus and NIM hardware modules and the VME exec real time operating system. A Unix based software package, written in ANSI standard C and with the XII graphics routines, allows the user to view the acquired spectra. Analysis of the histograms can be performed in background during the run with the ROBFIT suite of curve fitting routines

  5. Noise analysis and performance of a selfscanned linear InSb detector array

    International Nuclear Information System (INIS)

    Finger, G.; Meyer, M.; Moorwood, A.F.M.

    1987-01-01

    A noise model for detectors operated in the capacitive discharge mode is presented. It is used to analyze the noise performance of the ESO nested timing readout technique applied to a linear 32-element InSb array which is multiplexed by a silicon switched-FET shift register. Analysis shows that KTC noise of the videoline is the major noise contribution; it can be eliminated by weighted double-correlated sampling. Best noise performance of this array is achieved at the smallest possible reverse bias voltage (not more than 20 mV) whereas excess noise is observed at higher reverse bias voltages. 5 references

  6. Silicon detectors

    International Nuclear Information System (INIS)

    Klanner, R.

    1984-08-01

    The status and recent progress of silicon detectors for high energy physics is reviewed. Emphasis is put on detectors with high spatial resolution and the use of silicon detectors in calorimeters. (orig.)

  7. Robust MOE Detector for DS-CDMA Systems with Signature Waveform Mismatch

    Science.gov (United States)

    Lin, Tsui-Tsai

    In this letter, a decision-directed MOE detector with excellent robustness against signature waveform mismatch is proposed for DS-CDMA systems. Both the theoretic analysis and computer simulation results demonstrate that the proposed detector can provide better SINR performance than that of conventional detectors.

  8. Coverage matters: insurance and health care

    National Research Council Canada - National Science Library

    Board on Health Care Services Staff; Institute of Medicine Staff; Institute of Medicine; National Academy of Sciences

    2001-01-01

    ...? How does the system of insurance coverage in the U.S. operate, and where does it fail? The first of six Institute of Medicine reports that will examine in detail the consequences of having a large uninsured population, Coverage Matters...

  9. Religious subgroups influencing vaccination coverage in the Dutch Bible belt: an ecological study.

    Science.gov (United States)

    Ruijs, Wilhelmina L M; Hautvast, Jeannine L A; van der Velden, Koos; de Vos, Sjoerd; Knippenberg, Hans; Hulscher, Marlies E J L

    2011-02-14

    The Netherlands has experienced epidemics of vaccine preventable diseases largely confined to the Bible belt, an area where -among others- orthodox protestant groups are living. Lacking information on the vaccination coverage in this minority, and its various subgroups, control of vaccine preventable diseases is focused on the geographical area of the Bible belt. However, the adequacy of this strategy is questionable. This study assesses the influence of presence of various orthodox protestant subgroups (orthodox protestant denominations, OPDs) on municipal vaccination coverage in the Bible belt. We performed an ecological study at municipality level. Data on number of inhabitants, urbanization level, socio-economical status, immigration and vaccination coverage were obtained from national databases. As religion is not registered in the Netherlands, membership numbers of the OPDs had to be obtained from church year books and via church offices. For all municipalities in the Netherlands, the effect of presence or absence of OPDs on vaccination coverage was assessed by comparing mean vaccination coverage. For municipalities where OPDs were present, the effect of each of them (measured as membership ratio, the number of members proportional to total number of inhabitants) on vaccination coverage was assessed by bivariate correlation and multiple regression analysis in a model containing the determinants immigration, socio-economical status and urbanization as well. Mean vaccination coverage (93.5% ± 4.7) in municipalities with OPDs (n = 135) was significantly lower (p < 0.001) than in 297 municipalities without OPDs (96.9% ± 2.1). Multiple regression analyses showed that in municipalities with OPDs 84% of the variance in vaccination coverage was explained by the presence of these OPDs. Immigration had a significant, but small explanatory effect as well. Membership ratios of all OPDs were negatively related to vaccination coverage; this relationship was strongest for

  10. Media coverage of medical journals: do the best articles make the news?

    Science.gov (United States)

    Selvaraj, Senthil; Borkar, Durga S; Prasad, Vinay

    2014-01-01

    News coverage of medical research is followed closely by many Americans and affects the practice of medicine and influence of scientific research. Prior work has examined the quality of media coverage, but no investigation has characterized the choice of stories covered in a controlled manner. We examined whether the media systematically covers stories of weaker study design. We compared study characteristics of 75 clinically-oriented journal articles that received coverage in the top five newspapers by circulation against 75 clinically-oriented journal articles that appeared in the top five medical journals by impact factor over a similar timespan. Subgroup analysis was performed to determine whether differences between investigations from both sources varied by study type (randomized controlled trial [RCT] or observational study). Investigations receiving coverage from newspapers were less likely to be RCTs (17% vs. 35%, p = 0.016) and more likely to be observational studies (75% vs. 47%, pstudied (median: 1034 vs. 1901, p = 0.14) or length of follow-up (median: 1.80 vs. 1.00 years, p = 0.22). In subgroup analysis, observational studies from the media used smaller sample sizes (median: 1984 vs. 21136, p = 0.029) and were more likely to be cross-sectional (71% vs. 31%, pstudies and less likely to cover RCTs than high impact journals. Additionally, when the media does cover observational studies, they select articles of inferior quality. Newspapers preferentially cover medical research with weaker methodology.

  11. A combined segmented anode gas ionization chamber and time-of-flight detector for heavy ion elastic recoil detection analysis

    Science.gov (United States)

    Ström, Petter; Petersson, Per; Rubel, Marek; Possnert, Göran

    2016-10-01

    A dedicated detector system for heavy ion elastic recoil detection analysis at the Tandem Laboratory of Uppsala University is presented. Benefits of combining a time-of-flight measurement with a segmented anode gas ionization chamber are demonstrated. The capability of ion species identification is improved with the present system, compared to that obtained when using a single solid state silicon detector for the full ion energy signal. The system enables separation of light elements, up to Neon, based on atomic number while signals from heavy elements such as molybdenum and tungsten are separated based on mass, to a sample depth on the order of 1 μm. The performance of the system is discussed and a selection of material analysis applications is given. Plasma-facing materials from fusion experiments, in particular metal mirrors, are used as a main example for the discussion. Marker experiments using nitrogen-15 or oxygen-18 are specific cases for which the described improved species separation and sensitivity are required. Resilience to radiation damage and significantly improved energy resolution for heavy elements at low energies are additional benefits of the gas ionization chamber over a solid state detector based system.

  12. Blind Reduced-Rank MMSE Detector for DS-CDMA Systems

    Directory of Open Access Journals (Sweden)

    Xiaodong Cai

    2003-01-01

    Full Text Available We first develop a reduced-rank minimum mean squared error (MMSE detector for direct-sequence (DS code division multiple access (CDMA by forcing the linear MMSE detector to lie in a signal subspace of a reduced dimension. While a reduced-rank MMSE detector has lower complexity, it cannot outperform the full-rank MMSE detector. We then concentrate on the blind reduced-rank MMSE detector which is obtained from an estimated covariance matrix. Our analysis and simulation results show that when the desired user′s signal is in a low-dimensional subspace, there exists an optimal subspace so that the blind reduced-rank MMSE detector lying in this subspace has the best performance. By properly choosing a subsspace, we guarantee that the optimal blind reduced-rank MMSE detector is obtained. An adaptive blind reduced-rank MMSE detector, based on a subspace tracking algorithm, is developed. The adaptive blind reduced-rank MMSE detector exhibits superior steady-state performance and fast convergence speed.

  13. Resolution requirements for monitor viewing of digital flat-panel detector radiographs: a contrast detail analysis

    International Nuclear Information System (INIS)

    Peer, Siegfried; Giacomuzzi, Salvatore M.; Peer, Regina; Gassner, Eva; Steingruber, Iris; Jaschke, Werner

    2003-01-01

    With the introduction of digital flat-panel detector systems into clinical practice, the still unresolved question of resolution requirements for picture archiving communication system (PACS) workstation monitors has gained new momentum. This contrast detail analysis was thus performed to define the differences in observer performance in the detection of small low-contrast objects on clinical 1K and 2K monitor workstations. Images of the CDRAD 2.0 phantom were acquired at varying exposures on an indirect-type digital flat-panel detector. Three observers evaluated a total of 15 images each with respect to the threshold contrast for each detail size. The numbers of correctly identified objects were determined for all image subsets. No significant difference in the correct detection ratio was detected among the observers; however, the difference between the two types of workstations (1K vs 2K monitors) despite less than 3% was significant at a 95% confidence level. Slight but statistically significant differences exist in the detection of low-contrast nodular details visualized on 1K- and 2K-monitor workstations. Further work is needed to see if this result holds true also for comparison of clinical flat-panel detector images and may, for example, exert an influence on the diagnostic accuracy of chest X-ray readings. (orig.)

  14. Rise time spectroscopy in cadmium telluride detectors

    International Nuclear Information System (INIS)

    Scharager, Claude; Siffert, Paul; Carnet, Bernard; Le Meur, Roger.

    1980-11-01

    By a simultaneous analysis of rise time and pulse amplitude distributions of the signals issued from various cadmium telluride detectors, it is possible to obtain informations about surface and bulk trapping, field distribution within the detectors, as well as charge collection and transport properties. These investigations have been performed on both pure and chlorine doped and materials for various surfaces preparation conditions [fr

  15. Health insurance coverage and its impact on medical cost: observations from the floating population in China.

    Directory of Open Access Journals (Sweden)

    Yinjun Zhao

    Full Text Available China has the world's largest floating (migrant population, which has characteristics largely different from the rest of the population. Our goal is to study health insurance coverage and its impact on medical cost for this population.A telephone survey was conducted in 2012. 644 subjects were surveyed. Univariate and multivariate analysis were conducted on insurance coverage and medical cost.82.2% of the surveyed subjects were covered by basic insurance at hometowns with hukou or at residences. Subjects' characteristics including age, education, occupation, and presence of chronic diseases were associated with insurance coverage. After controlling for confounders, insurance coverage was not significantly associated with gross or out-of-pocket medical cost.For the floating population, health insurance coverage needs to be improved. Policy interventions are needed so that health insurance can have a more effective protective effect on cost.

  16. Vaccination coverage and timeliness in three South African areas: a prospective study

    Directory of Open Access Journals (Sweden)

    Sanders David

    2011-05-01

    Full Text Available Abstract Background Timely vaccination is important to induce adequate protective immunity. We measured vaccination timeliness and vaccination coverage in three geographical areas in South Africa. Methods This study used vaccination information from a community-based cluster-randomized trial promoting exclusive breastfeeding in three South African sites (Paarl in the Western Cape Province, and Umlazi and Rietvlei in KwaZulu-Natal between 2006 and 2008. Five interview visits were carried out between birth and up to 2 years of age (median follow-up time 18 months, and 1137 children were included in the analysis. We used Kaplan-Meier time-to-event analysis to describe vaccination coverage and timeliness in line with the Expanded Program on Immunization for the first eight vaccines. This included Bacillus Calmette-Guérin (BCG, four oral polio vaccines and 3 doses of the pentavalent vaccine which protects against diphtheria, pertussis, tetanus, hepatitis B and Haemophilus influenzae type B. Results The proportion receiving all these eight recommended vaccines were 94% in Paarl (95% confidence interval [CI] 91-96, 62% in Rietvlei (95%CI 54-68 and 88% in Umlazi (95%CI 84-91. Slightly fewer children received all vaccines within the recommended time periods. The situation was worst for the last pentavalent- and oral polio vaccines. The hazard ratio for incomplete vaccination was 7.2 (95%CI 4.7-11 for Rietvlei compared to Paarl. Conclusions There were large differences between the different South African sites in terms of vaccination coverage and timeliness, with the poorer areas of Rietvlei performing worse than the better-off areas in Paarl. The vaccination coverage was lower for the vaccines given at an older age. There is a need for continued efforts to improve vaccination coverage and timeliness, in particular in rural areas. Trial registration number ClinicalTrials.gov: NCT00397150

  17. Analysis of Arctic Sea ice coverage in 2012 using multi-source scatterometer data

    Science.gov (United States)

    Zhai, M.

    2013-12-01

    Arctic sea ice extent, regarded as an indicator of climate change, has been declining for the past few decades and reached the lowest ice extent in satellite record during the summer of 2012. Scatterometers can be used in sea ice identification, due to its ability to measure the backscatter characteristics of surface coverage. Thus, daily scatterometer data can be used in Arctic sea ice monitoring. In this paper, we compared the similarity and difference of three different scatterometer datasets, including ASCAT(METOP-A/B Advanced scatterometer) data, OSCAT(Oceansat-2 scatterometer)data and China's HY-2 scatterometer data, and then evaluated their performance in Artic sea ice investigation. We also constructed the sea ice coverage time series in 2012 using different scatterometer data and analyzed its temporal and spatial variation. Preliminary Results show that the maximum extent was set on 19 March, 2012. Cracks started to appear in Arctic sea ice coverage near New Siberian Islands on 18,May. Later, melt process accelerates in July and August. The northeast passage is not open until late August. On 18 September, the extent reached the minimum level and the refreezing process began. The duration of melting season is slightly shorter than the average level over the period of 1978 to 2012(ERS-1/2 scattermeter and Quickscat scatterometer data are used as supplementary records). The record low extent is likely resulted from (1)Arctic dipole pressure pattern, bringing in warm southerly winds and enhancing arctic ice discharge in Fram Strait and (2)relatively warm conditions over the Arctic areas.

  18. The simulation of the LANFOS-H food radiation contamination detector using Geant4 package

    Science.gov (United States)

    Piotrowski, Lech Wiktor; Casolino, Marco; Ebisuzaki, Toshikazu; Higashide, Kazuhiro

    2015-02-01

    Recent incident in the Fukushima power plant caused a growing concern about the radiation contamination and resulted in lowering the Japanese limits for the permitted amount of 137Cs in food to 100 Bq/kg. To increase safety and ease the concern we are developing LANFOS (Large Food Non-destructive Area Sampler)-a compact, easy to use detector for assessment of radiation in food. Described in this paper LANFOS-H has a 4 π coverage to assess the amount of 137Cs present, separating it from the possible 40K food contamination. Therefore, food samples do not have to be pre-processed prior to a test and can be consumed after measurements. It is designed for use by non-professionals in homes and small institutions such as schools, showing safety of the samples, but can be also utilized by specialists providing radiation spectrum. Proper assessment of radiation in food in the apparatus requires estimation of the γ conversion factor of the detectors-how many γ photons will produce a signal. In this paper we show results of the Monte Carlo estimation of this factor for various approximated shapes of fish, vegetables and amounts of rice, performed with Geant4 package. We find that the conversion factor combined from all the detectors is similar for all food types and is around 37%, varying maximally by 5% with sample length, much less than for individual detectors. The different inclinations and positions of samples in the detector introduce uncertainty of 1.4%. This small uncertainty validates the concept of a 4 π non-destructive apparatus.

  19. Fast microchannel plate detector for particles

    International Nuclear Information System (INIS)

    Wurz, P.; Gubler, L.

    1996-01-01

    In this article we report on the timing capabilities of a new microchannel plate detector we designed and built. The detector assembly has an impedance-matched transition line (50 Ω line resistance) from anode to cable connector which is considerably smaller than other, commercially available solutions and at the same time has about four times the active area. The detector was tested with an alpha particle source and excellent time response was achieved. Using 10 μm pore size channel plates, a rise time of 300 ps and a pulse width of 520 ps are obtained. The details of the signal analysis are also given in the article. copyright 1996 American Institute of Physics

  20. Immunization Coverage

    Science.gov (United States)

    ... room/fact-sheets/detail/immunization-coverage","@context":"http://schema.org","@type":"Article"}; العربية 中文 français русский español ... Plan Global Health Observatory (GHO) data - Immunization More information on vaccines and immunization News 1 in 10 ...

  1. Ion detectors for isotopic measurements

    Energy Technology Data Exchange (ETDEWEB)

    McCormick, A.

    1978-12-15

    Detector development over the past two decades has been such that this is now the least likely part of the mass spectrometry equipment to give rise to the sort of measurement errors to cause concern. It is now possible to choose from a number of different types of device which can provide more or less 100% efficiency in ion beam detection under all conceivable experimental conditions required for isotopic analysis, from measurement of large samples using the traditional Faraday cage to measurement of exceedingly small ion currents by ion counting techniques. There are even methods of distinguishing one type of ionic species from another in the detector, thus improving the accuracy when unwanted isobaric species might otherwise grossly distort the measurement. Notable contributions to detector development for nuclear measurements have been made by Dietz at the Knolls Atomic Power Laboratory, by Barnett at Oak Ridge and by Daly at Atomic Weapons Research Establishment (AWRE), Aldermaston. This paper describes the detection methods which are currently in use at AWRE for isotopic analysis of solid samples for routine applications as well as non-routine applications. Other methods are merely mentioned as a stimulus for discussion.

  2. The Cryogenic Anti-Coincidence detector for ATHENA X-IFU: pulse analysis of the AC-S7 single pixel prototype

    Science.gov (United States)

    D'Andrea, M.; Argan, A.; Lotti, S.; Macculi, C.; Piro, L.; Biasotti, M.; Corsini, D.; Gatti, F.; Torrioli, G.

    2016-07-01

    The ATHENA observatory is the second large-class mission in ESA Cosmic Vision 2015-2025, with a launch foreseen in 2028 towards the L2 orbit. The mission addresses the science theme "The Hot and Energetic Universe", by coupling a high-performance X-ray Telescope with two complementary focal-plane instruments. One of these is the X-ray Integral Field Unit (X-IFU): it is a TES based kilo-pixel order array able to provide spatially resolved high-resolution spectroscopy (2.5 eV at 6 keV) over a 5 arcmin FoV. The X-IFU sensitivity is degraded by the particles background expected at L2 orbit, which is induced by primary protons of both galactic and solar origin, and mostly by secondary electrons. To reduce the background level and enable the mission science goals, a Cryogenic Anticoincidence (CryoAC) detector is placed address the final design of the CryoAC. It will verify some representative requirements at single-pixel level, especially the detector operation at 50 mK thermal bath and the threshold energy at 20 keV. To reach the final DM design we have developed and tested the AC-S7 prototype, with 1 cm2 absorber area sensed by 65 Ir TESes. Here we will discuss the pulse analysis of this detector, which has been illuminated by the 60 keV line from a 241Am source. First, we will present the analysis performed to investigate pulses timings and spectrum, and to disentangle the athermal component of the pulses from the thermal one. Furthermore, we will show the application to our dataset of an alternative method of pulse processing, based upon Principal Component Analysis (PCA). This kind of analysis allow us to recover better energy spectra than achievable with traditional methods, improving the evaluation of the detector threshold energy, a fundamental parameter characterizing the CryoAC particle rejection efficiency.

  3. Mobility and powering of large detectors. Moving large detectors

    International Nuclear Information System (INIS)

    Thompson, J.

    1977-01-01

    The possibility is considered of moving large lepton detectors at ISABELLE for readying new experiments, detector modifications, and detector repair. A large annex (approximately 25 m x 25 m) would be built adjacent to the Lepton Hall separated from the Lepton Hall by a wall of concrete 11 m high x 12 m wide (for clearance of the detector) and approximately 3 m thick (for radiation shielding). A large pad would support the detector, the door, the cryogenic support system and the counting house. In removing the detector from the beam hall, one would push the pad into the annex, add a dummy beam pipe, bake out the beam pipe, and restack and position the wall on a small pad at the door. The beam could then operate again while experimenters could work on the large detector in the annex. A consideration and rough price estimate of various questions and proposed solutions are given

  4. Socio-economic determinants and inequities in coverage and timeliness of early childhood immunisation in rural Ghana.

    Science.gov (United States)

    Gram, Lu; Soremekun, Seyi; ten Asbroek, Augustinus; Manu, Alexander; O'Leary, Maureen; Hill, Zelee; Danso, Samuel; Amenga-Etego, Seeba; Owusu-Agyei, Seth; Kirkwood, Betty R

    2014-07-01

    To assess the extent of socio-economic inequity in coverage and timeliness of key childhood immunisations in Ghana. Secondary analysis of vaccination card data collected from babies born between January 2008 and January 2010 who were registered in the surveillance system supporting the ObaapaVita and Newhints Trials was carried out. 20 251 babies had 6 weeks' follow-up, 16 652 had 26 weeks' follow-up, and 5568 had 1 year's follow-up. We performed a descriptive analysis of coverage and timeliness of vaccinations by indicators for urban/rural status, wealth and educational attainment. The association of coverage with socio-economic indicators was tested using a chi-square-test and the association with timeliness using Cox regression. Overall coverage at 1 year of age was high (>95%) for Bacillus Calmette-Guérin (BCG), all three pentavalent diphtheria-pertussis-tetanus-haemophilus influenzae B-hepatitis B (DPTHH) doses and all polio doses except polio at birth (63%). Coverage against measles and yellow fever was 85%. Median delay for BCG was 1.7 weeks. For polio at birth, the median delay was 5 days; all other vaccine doses had median delays of 2-4 weeks. We found substantial health inequity across all socio-economic indicators for all vaccines in terms of timeliness, but not coverage at 1 year. For example, for the last DPTHH dose, the proportion of children delayed more than 8 weeks were 27% for urban children and 31% for rural children (P < 0.001), 21% in the wealthiest quintile and 41% in the poorest quintile (P < 0.001), and 9% in the most educated group and 39% in the least educated group (P < 0.001). However, 1-year coverage of the same dose remained above 90% for all levels of all socio-economic indicators. Ghana has substantial health inequity across urban/rural, socio-economic and educational divides. While overall coverage was high, most vaccines suffered from poor timeliness. We suggest that countries achieving high coverage should include timeliness

  5. Parametric Adaptive Radar Detector with Enhanced Mismatched Signals Rejection Capabilities

    Directory of Open Access Journals (Sweden)

    Liu Bin

    2010-01-01

    Full Text Available We consider the problem of adaptive signal detection in the presence of Gaussian noise with unknown covariance matrix. We propose a parametric radar detector by introducing a design parameter to trade off the target sensitivity with sidelobes energy rejection. The resulting detector merges the statistics of Kelly's GLRT and of the Rao test and so covers Kelly's GLRT and the Rao test as special cases. Both invariance properties and constant false alarm rate (CFAR behavior for this detector are studied. At the analysis stage, the performance of the new receiver is assessed and compared with several traditional adaptive detectors. The results highlight better rejection capabilities of this proposed detector for mismatched signals. Further, we develop two two-stage detectors, one of which consists of an adaptive matched filter (AMF followed by the aforementioned detector, and the other is obtained by cascading a GLRT-based Subspace Detector (SD and the proposed adaptive detector. We show that the former two-stage detector outperforms traditional two-stage detectors in terms of selectivity, and the latter yields more robustness.

  6. The role of XML in the CMS detector description

    International Nuclear Information System (INIS)

    Liendl, M.; Lingen, F.van; Todorov, T.; Arce, P.; Furtjes, A.; Innocente, V.; Roeck, A. de; Case, M.

    2001-01-01

    Offline Software such as Simulation, Reconstruction, Analysis, and Visualisation are all in need of a detector description. These applications have several common but also many specific requirements for the detector description in order to build up their internal representations. To achieve this in a consistent and coherent manner a common source of information, the detector description database, will be consulted by each of the applications. The role and suitability of XML in the design of the detector description database in the scope of the CMS detector at the LHC is discussed. Different aspects such as data modelling capabilities of XML, tool support, integration to C++ representations of data models are treated and recent results of prototype implementations are presented

  7. 22 CFR 226.31 - Insurance coverage.

    Science.gov (United States)

    2010-04-01

    ... 22 Foreign Relations 1 2010-04-01 2010-04-01 false Insurance coverage. 226.31 Section 226.31 Foreign Relations AGENCY FOR INTERNATIONAL DEVELOPMENT ADMINISTRATION OF ASSISTANCE AWARDS TO U.S. NON-GOVERNMENTAL ORGANIZATIONS Post-award Requirements Property Standards § 226.31 Insurance coverage. Recipients...

  8. 14 CFR 1260.131 - Insurance coverage.

    Science.gov (United States)

    2010-01-01

    ... coverage. Recipients shall, at a minimum, provide the equivalent insurance coverage for real property and equipment acquired with Federal funds as provided for property owned by the recipient. Federally-owned property need not be insured unless required by the terms and conditions of the award. ...

  9. Quantitative microanalysis in the analytical electronmicroscope using an HPGe-x ray detector

    International Nuclear Information System (INIS)

    Grogger, W.

    1994-01-01

    Energy dispersive x-ray spectrometry (EDX) is a routine method for determining the chemical composition of a sample in the analytical electronmicroscope. Since some years high purity germanium x-ray detectors (HPGe) are commercially available for use in EDX. This new type of detector offers some advantages over the commonly used Si (Li) detector: better energy resolution, better detector efficiency for high energy lines (> 30 keV) and better stability against exterior influences. For quantitative analysis one needs sensitivity factors (k-factors), which correlate the measured intensity to the concentration of a specific element. These k-factors can be calculated or determined experimentally. For a precise quantitative analysis of light elements measured k-factors are absolutely necessary. In this study k-factors were measured with an HPGe detector using standards. The accuracy of the k-factors was proved using some examples of practical relevance. Additionally some special features of the HPGe detector were examined, which lead to a better understanding of EDX spectrometry using an HPGe detector (escape lines, icing of the detector, artifacts). (author)

  10. MUON DETECTORS: RPC

    CERN Multimedia

    P. Paolucci

    2011-01-01

    During data-taking in 2010 the RPC system behaviour was very satisfactory for both the detector and trigger performances. Most of the data analyses are now completed and many results and plots have been approved in order to be published in the muon detector paper. A very detailed analysis of the detector efficiency has been performed using 60 million muon events taken with the dedicated RPC monitor stream. The results have shown that the 96.3% of the system was working properly with an average efficiency of 95.4% at 9.35 kV in the Barrel region and 94.9% at 9.55 kV in the Endcap. Cluster size goes from 1.6 to 2.2 showing a clear and well-known correlation with the strip pitch. Average noise in the Barrel is less than 0.4 Hz/cm2 and about 98% of full system has averaged noise less then 1 Hz/cm2. A linear dependence of the noise versus the luminosity has been preliminary observed and is now under study. Detailed chamber efficiency maps have shown a few percent of chambers with a non-uniform efficiency distribu...

  11. Spent-fuel characterization with small CZT detectors

    Energy Technology Data Exchange (ETDEWEB)

    Berndt, R. [European Commission, Joint Research Centre, Ispra, 21020 Ispra (Vatican City State, Holy See,) (Italy)]. E-mail: Reinhard.Berndt@jrc.it; Mortreau, P. [European Commission, Joint Research Centre, Ispra, 21020 Ispra (Va) (Italy)

    2006-08-01

    CdTe detectors may be utilised as miniature instruments for the measurement of gamma spectra in safeguards applications [R. Arlt, V. Gryshchuk, P. Sumah, Nucl. Instr. and Meth. A 428 (1999) 127]. This is applicable for measurements both to fresh fuel and irradiated nuclear fuel. The spectrum analysis, however, is more complicated than with Ge detectors. Some reasons are: the peaks are asymmetric, the peak/Compton ratio is low, peak parameters depend on the count rate and on the properties of individual detector crystals. We developed a spectrum-unfolding code for spectra obtained with CdTe detectors. The code makes use of a series of pattern spectra of the individual instrument. It is applied to fission-product spectra and allows the coarse characterisation of the spent fuel in safeguards inspections.

  12. Spent-fuel characterization with small CZT detectors

    International Nuclear Information System (INIS)

    Berndt, R.; Mortreau, P.

    2006-01-01

    CdTe detectors may be utilised as miniature instruments for the measurement of gamma spectra in safeguards applications [R. Arlt, V. Gryshchuk, P. Sumah, Nucl. Instr. and Meth. A 428 (1999) 127]. This is applicable for measurements both to fresh fuel and irradiated nuclear fuel. The spectrum analysis, however, is more complicated than with Ge detectors. Some reasons are: the peaks are asymmetric, the peak/Compton ratio is low, peak parameters depend on the count rate and on the properties of individual detector crystals. We developed a spectrum-unfolding code for spectra obtained with CdTe detectors. The code makes use of a series of pattern spectra of the individual instrument. It is applied to fission-product spectra and allows the coarse characterisation of the spent fuel in safeguards inspections

  13. 2011 ATLAS Detector Performance - ID and Forward detectors

    CERN Document Server

    Davies‎, E; The ATLAS collaboration; Abdel Khalek, S

    2012-01-01

    This poster describes the performance of 2 parts of ATLAS: - The Inner Detector which consists of 3 subdetectors: the Pixel detector, the SemiConductor Tracker (or SCT) and the Transition Radiation Tracker (or TRT). Here, we report on Pixel detector and SCT performance over 2011. - ALFA detector which will determine the absolute luminosity of the CERN LHC at the ATLAS Interaction Point (IP), and the total proton-proton cross section, by tracking elastically scattered protons at very small angles in the limit of the Coulomb Nuclear interference region.

  14. 7 CFR 1737.31 - Area Coverage Survey (ACS).

    Science.gov (United States)

    2010-01-01

    ... an ACS are provided in RUS Telecommunications Engineering and Construction Manual section 205. (e... Studies-Area Coverage Survey and Loan Design § 1737.31 Area Coverage Survey (ACS). (a) The Area Coverage... the borrower's records contain sufficient information as to subscriber development to enable cost...

  15. Infrared detectors

    CERN Document Server

    Rogalski, Antonio

    2010-01-01

    This second edition is fully revised and reorganized, with new chapters concerning third generation and quantum dot detectors, THz detectors, cantilever and antenna coupled detectors, and information on radiometry and IR optics materials. Part IV concerning focal plane arrays is significantly expanded. This book, resembling an encyclopedia of IR detectors, is well illustrated and contains many original references … a really comprehensive book.-F. Sizov, Institute of Semiconductor Physics, National Academy of Sciences, Kiev, Ukraine

  16. The DELPHI Microvertex detector

    International Nuclear Information System (INIS)

    Bingefors, N.; Borner, H.; Boulter, R.; Caccia, M.; Chabaud, V.; Dijkstra, H.; Eerola, P.; Gross, E.; Horisberger, R.; Hubbeling, L.; Hyams, B.; Karlsson, M.; Maehlum, G.; Ratz, K.; Roditi, I.; Straver, J.; Trischuk, W.; Weilhammer, P.; Dufour, Y.; Brueckman, P.; Jalocha, P.; Kapusta, P.; Turala, M.; Zalewska, A.; Lindgren, J.; Orava, R.; Oesterberg, K.; Ronnqvist, C.; Saarikko, H.; Saarikko, J.P.; Tuuva, T.; Almagne, B. d'; Bambade, P.; Couchot, F.; Fulda, F.; Amery, A.; Booth, P.S.L.; Campion, A.R.; McNulty, R.; Smith, N.A.; Andreazza, A.; Battaglia, M.; Biffi, P.; Bonvicini, V.; Kucewicz, W.; Meroni, C.; Redaelli, N.; Stocchi, A.; Troncon, C.; Vegni, G.; Dauncey, P.; Mazzucato, M.; Pegoraro, M.; Peisert, A.; Baubillier, M.; Chauveau, J.; Silva, W. da; Genat, J.F.; Rossel, F.; Adye, T.; Apsimon, R.; Bizell, J.; Denton, L.; Kalmus, G.E.; Lidbury, J.; Seller, P.; Tyndel, M.; Dulinski, W.; Husson, D.; Lounis, A.; Schaeffer, M.; Turchetta, R.; Brenner, R.; Sundell, E.

    1993-01-01

    The DELPHI Microvertex detector, which has been in operation since the start of the 1990 LEP run, consists of three layers of silicon microstrip detectors at average radii of 6.3, 9.0 and 11.0 cm. The 73 728 readout strips, oriented along the beam, have a total active area of 0.42 m 2 . The strip pitch is 25 μm and every other strip is read out by low power charge amplifiers, giving a signal to noise ratio of 15:1 for minimum ionizing particles. On-line zero suppression results in an average data size of 4 kbyte for Z 0 events. After a mechanical survey and an alignment with tracks, the impact parameter uncertainty as determined from hadronic Z 0 decays is well described by √(69/p t ) 2 +24 2 μm, with p t in GeV/c. For the 45 GeV/c tracks from Z 0 →μ + μ - decays we find an uncertainty of 21 μm for the impact parameter, which corresponds to a precision of 8 μm per point. The stability during the run is monitored using light spots and capacitive probes. An analysis of tracks through sector overlaps provides an additional check of the stability. The same analysis also results in a value of 6 μm for the intrinsic precision of the detector. (orig.)

  17. Neutron counting and gamma spectroscopy with PVT detectors

    International Nuclear Information System (INIS)

    Mitchell, Dean James; Brusseau, Charles A.

    2011-01-01

    Radiation portals normally incorporate a dedicated neutron counter and a gamma-ray detector with at least some spectroscopic capability. This paper describes the design and presents characterization data for a detection system called PVT-NG, which uses large polyvinyl toluene (PVT) detectors to monitor both types of radiation. The detector material is surrounded by polyvinyl chloride (PVC), which emits high-energy gamma rays following neutron capture reactions. Assessments based on high-energy gamma rays are well suited for the detection of neutron sources, particularly in border security applications, because few isotopes in the normal stream of commerce have significant gamma ray yields above 3 MeV. Therefore, an increased count rate for high-energy gamma rays is a strong indicator for the presence of a neutron source. The sensitivity of the PVT-NG sensor to bare 252 Cf is 1.9 counts per second per nanogram (cps/ng) and the sensitivity for 252 Cf surrounded by 2.5 cm of polyethylene is 2.3 cps/ng. The PVT-NG sensor is a proof-of-principal sensor that was not fully optimized. The neutron detector sensitivity could be improved, for instance, by using additional moderator. The PVT-NG detectors and associated electronics are designed to provide improved resolution, gain stability, and performance at high-count rates relative to PVT detectors in typical radiation portals. As well as addressing the needs for neutron detection, these characteristics are also desirable for analysis of the gamma-ray spectra. Accurate isotope identification results were obtained despite the common impression that the absence of photopeaks makes data collected by PVT detectors unsuitable for spectroscopic analysis. The PVT detectors in the PVT-NG unit are used for both gamma-ray and neutron detection, so the sensitive volume exceeds the volume of the detection elements in portals that use dedicated components to detect each type of radiation.

  18. Germanium cryogenic detectors: Alpha surface events rejection capabilities

    International Nuclear Information System (INIS)

    Fiorucci, S.; Broniatowski, A.; Chardin, G.; Censier, B.; Lesquen, A. de; Deschamps, H.; Fesquet, M.; Jin, Y.

    2006-01-01

    Alpha surface events and multiple compton gamma interactions are the two major background components in Ge detectors for double-beta decay investigations. Two different methods have been studied to identify such type of events, using cryogenic Ge detectors developed primarily for dark matter search: (i) combined heat and ionization measurements, and (ii) pulse-shape analysis of the charge collection signals. Both methods show strong separation between electron recoil events and surface alphas. Cryogenic heat-ionization detectors therefore appear able to reject virtually all surface alpha interactions

  19. Qualitative and quantitative analysis of cations and anions using ion selective detectors in capillary electrophoresis

    International Nuclear Information System (INIS)

    Nann, A.

    1994-01-01

    The present work reports on the application of ion-selective microelectrodes as potentiometric detectors for the qualitative and quantitative analysis of cations and anions separated by capillary electrophoresis. Due to the high internal resistance of microelectrodes, their potentials are strongly affected by external electrical fields. Therefore, the influence of the electrophoretic field on the electrode response had to be kept at a minimum. With the electrode tip inserted in the capillary aperture (on-column detection), heavy drifts and noise of the signals were observed, mainly because the electrophoretic potential is superimposed on the Nernstian electrode response. As the potential inside the capillary is site-dependent, already minor movements and vibrations not perceptible under the light microscopy cause unacceptable disturbances of the electrode signal. One possibility to solve the problem consists in post- or off-column detection, i.e., with the detector located outside the influence of the electrophoretic field. If quantitative analyses with maximum resolution are to be achieved, only on-column detection is suitable because outside the capillary, the separation efficiency drops drastically. By etching the detector-side capillary end to a conical aperture, the field strength in the last 10 μm fell approximately 1/25 as compared with that in a cylindrical one. Thus, potential drifts and noise were reduced correspondingly so that on-column detection can also be used for potentiometric detection. To obtain quantitative results, the signals of the ion-selective detector were first delogarithmized and then integrated over time. Thus, it was possible to quantify cations and anions with a coefficient of variations ≤5%. (author) figs., tabs., 179 refs

  20. 2 CFR 215.31 - Insurance coverage.

    Science.gov (United States)

    2010-01-01

    ... Insurance coverage. Recipients shall, at a minimum, provide the equivalent insurance coverage for real property and equipment acquired with Federal funds as provided to property owned by the recipient. Federally-owned property need not be insured unless required by the terms and conditions of the award. ...